  1. Dosimetry on ocular brachytherapy with ROPE plaque with iodine125 and palladium-103

    International Nuclear Information System (INIS)

    Mourao, Arnaldo P.; Campos, Tarcisio

    2009-01-01

    Radiotherapy is an alternative to ocular enucleation. However, the irradiation of ocular region can bring deleterious effects due to the high doses, mainly in the lens, retina and in the bone structures in growth phase. Brachytherapy instead of teletherapy looks for departing absorbed doses in tumor minimizing doses in the lens and the adjacent tissues of the eyeball (orbital region), avoiding deleterious effects. Thus, a three-dimensional computational model of ocular area was developed to simulate orbital irradiation with ROPES ophthalmologic plaque placed on the sclera surface filled to ten iodine-125 seeds, and palladium-103 seeds. Simulations are performed on the MCNP5 code. The computational simulation allows evaluating how the dose rates are spatially distributed in the orbital volume. The results are normalized to 100% at the maximum dose on the tumor base, and by the applied source activity. The maximum dose is found onto the eyeball, in the vitreous. The present model represents an advance in simulating and predicting absorbed dose on ocular brachytherapy. (author)

  2. Dosimetry on ocular brachytherapy with ROPES plaque with Iodine-125 and Palladium-103 seeds

    International Nuclear Information System (INIS)

    Mourao, Arnaldo P.; Campos, Tarcisio P.R.

    2010-01-01

    Radiotherapy is an alternative to ocular enucleation. However, the irradiation of ocular region can bring deleterious effects due to the high doses, mainly in the lens, retina and in the bone structures in growth phase. Brachytherapy instead of teletherapy looks for departuring absorbed doses in tumor minimizing doses in the lens and the adjacent tissues of the eyeball (orbital region), avoiding deleterious effects. Thus, a three-dimensional computational model of ocular area was developed to simulate orbital irradiation with ROPES ophthalmologic plaque placed on the sclera surface filled to ten iodine-125 seeds, and palladium-103 seeds. Simulations are performed on the MCNP5 code. The computational simulation allows evaluating how the dose rates are spatially distributed in the orbital volume. The results are normalized to 100% at the maximum dose on the tumor base, and by the applied source activity. The maximum dose is found onto the eyeball, in the vitreous. The present model represents an advance in simulating and predicting absorbed dose on ocular brachytherapy. (author)

  3. A new inexpensive customized plaque for choroidal melanoma iodine-125 plaque therapy

    International Nuclear Information System (INIS)

    Vine, A.K.; Tenhaken, R.K.; Diaz, R.F.; Maxson, B.B.; Lichter, A.S.

    1989-01-01

    The authors have developed a new inexpensive precious metal alloy plaque for use in customized iodine-125 plaque therapy. Each plaque is formed from two flat circular gold/palladium foils which are used in dental crown work. Using a simple manual mechanism, the two forms are stamped over a customized acrylic die shaped to the dimensions of the tumor base plus a 2-mm margin. Completed plaques consist of a back wall, a 2-mm side wall, and a 1.5-mm wide lip with holes for suture placement. Advantages include: simple construction from inexpensive components, customized shape, and iodine seeds that are readily visible on plane radiographs

  4. Dosimetry on ocular brachytherapy with ROPES plaque with Iodine-125 and Palladium-103 seeds; Dosimetria em braquiterapia ocular com placa ROPES contendo sementes de iodo-125 e paladium-103

    Energy Technology Data Exchange (ETDEWEB)

    Mourao, Arnaldo P. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET/MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar], e-mail: aprata@des.cefetmg.br; Campos, Tarcisio P.R. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares

    2010-03-15

    Radiotherapy is an alternative to ocular enucleation. However, the irradiation of ocular region can bring deleterious effects due to the high doses, mainly in the lens, retina and in the bone structures in growth phase. Brachytherapy instead of teletherapy looks for departuring absorbed doses in tumor minimizing doses in the lens and the adjacent tissues of the eyeball (orbital region), avoiding deleterious effects. Thus, a three-dimensional computational model of ocular area was developed to simulate orbital irradiation with ROPES ophthalmologic plaque placed on the sclera surface filled to ten iodine-125 seeds, and palladium-103 seeds. Simulations are performed on the MCNP5 code. The computational simulation allows evaluating how the dose rates are spatially distributed in the orbital volume. The results are normalized to 100% at the maximum dose on the tumor base, and by the applied source activity. The maximum dose is found onto the eyeball, in the vitreous. The present model represents an advance in simulating and predicting absorbed dose on ocular brachytherapy. (author)

  5. Dosimetry on ocular brachytherapy with ROPE plaque with iodine{sub 1}25 and palladium-103;Dosimetria em braquiterapia ocular com placa ROPES contando sementes de iodo-125 e paladio-103

    Energy Technology Data Exchange (ETDEWEB)

    Mourao, Arnaldo P. [Centro Federal de Educacao Tecnologica (CEFET/MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar; Campos, Tarcisio [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares

    2009-07-01

    Radiotherapy is an alternative to ocular enucleation. However, the irradiation of ocular region can bring deleterious effects due to the high doses, mainly in the lens, retina and in the bone structures in growth phase. Brachytherapy instead of teletherapy looks for departing absorbed doses in tumor minimizing doses in the lens and the adjacent tissues of the eyeball (orbital region), avoiding deleterious effects. Thus, a three-dimensional computational model of ocular area was developed to simulate orbital irradiation with ROPES ophthalmologic plaque placed on the sclera surface filled to ten iodine-125 seeds, and palladium-103 seeds. Simulations are performed on the MCNP5 code. The computational simulation allows evaluating how the dose rates are spatially distributed in the orbital volume. The results are normalized to 100% at the maximum dose on the tumor base, and by the applied source activity. The maximum dose is found onto the eyeball, in the vitreous. The present model represents an advance in simulating and predicting absorbed dose on ocular brachytherapy. (author)

  6. Alternative Dose for Choroidal Melanoma Treated With an Iodine-125 Radioactive Plaque: A Single-Institution Retrospective Study

    International Nuclear Information System (INIS)

    Saconn, Paul A.; Gee, Christopher J.; Greven, Craig M.; McCoy, Thomas P.; Ekstrand, Kenneth E.; Greven, Kathryn M.

    2010-01-01

    Purpose: The Collaborative Ocular Melanoma Study (COMS) established iodine-125 plaque brachytherapy as an accepted standard treatment for medium-size choroidal melanoma. In the COMS, the prescription dose was 85 Gy. This is a retrospective review of our outcomes in patients treated with lower doses than those used in the COMS. Methods and Materials: From 1990 to 2004, 62 patients were treated with iodine-125 plaque brachytherapy for choroidal melanoma. COMS eye plaques were used with dose prescribed to the apex of the tumor. The median and average dose rates at the tumor apex were 63.5 cGy/h and 62.7 cGy/h, respectively. The median and average total doses were 63.0 Gy and 62.5 Gy (range, 56-69 Gy), respectively. The median and mean durations of implant were 100.0 hours and 101.1 hours (range, 71-165 hours). Results: Median follow-up time was 58.2 months. The 5-year outcomes including overall survival, disease-free survival, cause-specific survival, local failure, secondary enucleation rate, and visual acuity (VA) <20/200 were estimated using the Kaplan-Meier method. Overall, there were 7 local failures, 4 distant failures, and 10 secondary enucleations (6 due to local failure and 4 due to treatment complications). Univariate analysis was performed to identify significant prognostic factors associated with disease-free survival (baseline VA in tumor eye, tumor shape), cause-specific survival (diabetic retinopathy), local failure (none found), secondary enucleation rate (diabetic retinopathy, basal tumor dimension) and VA <20/200 (diabetic retinopathy, tumor shape, age, retinal detachment, treatment depth, and history of vision-limiting condition). Conclusions: Our survival and local control outcomes are comparable to those of the COMS. However, VA at 5 years seems to be better. Lower doses of radiation could potentially lead to better visual outcomes.

  7. Dosimetry on ocular brachytherapy with I-125 ophthalmologic ROPES and COMS plaques

    International Nuclear Information System (INIS)

    Mourao, Arnaldo P.; Campos, Tarcisio P.R.

    2009-01-01

    Radiotherapy is an alternative to ocular enucleation. However, the irradiation of ocular region can bring deleterious effects due to the high doses, mainly in the lens, retina and in the bone structures in growth phase. Brachytherapy instead of teletherapy looks for departuring absorbed doses in tumor minimizing doses in the lens and the adjacent tissues of the eyeball (orbital region), avoiding deleterious effects. Thus, a three-dimensional computational voxel model and an analytical model were coupled, including the heterogeneous properties of the globe and the adjacent tissues. The analytical model was applied to define the thin structures of the ocular globe. This computational model is used to simulate orbital irradiation with ROPES and COMS ophthalmologic plaques placed on the sclera surface filled to ten and eight iodine-125 seeds, respectively. Simulations are performed on the MCNP5 code. The computational simulation allows evaluating how the dose rates are spatially distributed in the orbital volume. The results are normalized to 100% at the maximum dose on the tumor base, and by the applied source activity. The external globe structures receive 0.5% of the maximum internal dose. The crystalline lens dosimetry depends on the position and thickness of the tumor and the plaque diameters. On the present case, 12.75% of maximum dose is found on the lens. The maximum dose is found onto the eyeball, in the vitreous. The present model represents an advance in simulating and predicting absorbed dose on ocular brachytherapy, incorporating anthropomorphic and anthropometric features of the real eyeball. (author)

  8. Dosimetry on ocular brachytherapy with I-125 ophthalmologic ROPES and COMS plaques

    Energy Technology Data Exchange (ETDEWEB)

    Mourao, Arnaldo P. [Centro Federal de Educacao Tecnoloica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar], e-mail: aprata@des.cefetmg.br; Campos, Tarcisio P.R. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares], e-mail: campos@nuclear.ufmg.br

    2009-07-01

    Radiotherapy is an alternative to ocular enucleation. However, the irradiation of ocular region can bring deleterious effects due to the high doses, mainly in the lens, retina and in the bone structures in growth phase. Brachytherapy instead of teletherapy looks for departuring absorbed doses in tumor minimizing doses in the lens and the adjacent tissues of the eyeball (orbital region), avoiding deleterious effects. Thus, a three-dimensional computational voxel model and an analytical model were coupled, including the heterogeneous properties of the globe and the adjacent tissues. The analytical model was applied to define the thin structures of the ocular globe. This computational model is used to simulate orbital irradiation with ROPES and COMS ophthalmologic plaques placed on the sclera surface filled to ten and eight iodine-125 seeds, respectively. Simulations are performed on the MCNP5 code. The computational simulation allows evaluating how the dose rates are spatially distributed in the orbital volume. The results are normalized to 100% at the maximum dose on the tumor base, and by the applied source activity. The external globe structures receive 0.5% of the maximum internal dose. The crystalline lens dosimetry depends on the position and thickness of the tumor and the plaque diameters. On the present case, 12.75% of maximum dose is found on the lens. The maximum dose is found onto the eyeball, in the vitreous. The present model represents an advance in simulating and predicting absorbed dose on ocular brachytherapy, incorporating anthropomorphic and anthropometric features of the real eyeball. (author)

  9. Iodine-125 seed implantation (permanent brachytherapy) for clinically localized prostate cancer

    International Nuclear Information System (INIS)

    Ebara, Shin; Katayama, Yoshihisa; Tanimoto, Ryuta

    2008-01-01

    From January 2004 to March 2007, 308 patients with clinically localized prostate cancer were treated using iodine-125 ( 125 I) seed implantation (permanent brachytherapy) at Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences. We evaluated the treatment's efficacy and morbidity in 300 prostate cancer patients who were followed up for more than 1 month after brachytherapy. Based on the National Comprehensive Cancer Network (NCCN) guidelines, patients with a prostate volume of less than 40 ml in transrectal ultrasound imaging were classified as low or intermediate risk. The median patient age was 67 years (range 50 to 79 years), the median prostate-specific antigen (PSA) value before biopsy was 6.95 ng/ml (range 1.13 to 24.7 ng/ml), and the median prostate volume was 24.33 ml (range 9.3 to 41.76 ml). The median follow-up was 18 months (range 1 to 36 months) and the PSA levels decreased in almost all patients after brachytherapy. Although 194 of 300 patients (64.7%) complained of difficulty in urination, pollakisuria/urgency, miction pain, and/or urinary incontinence, all of which might be associated with radiation prostatitis during the first month after brachytherapy, these symptoms gradually improved. 125 I seed implantation brachytherapy is safe and effective for localized prostate cancer within short-term follow up. (author)

  10. Iodine 125 Brachytherapy With Vitrectomy and Silicone Oil in the Treatment of Uveal Melanoma: 1-to-1 Matched Case-Control Series

    International Nuclear Information System (INIS)

    McCannel, Tara A.; McCannel, Colin A.

    2014-01-01

    Purpose: We initially reported the radiation-attenuating effect of silicone oil 1000 centistokes for iodine 125. The purpose of this report was to compare the clinical outcomes in case patients who had iodine 125 brachytherapy with vitrectomy and silicone oil 1000 centistokes with the outcomes in matched control patients who underwent brachytherapy alone. Methods and Materials: Consecutive patients with uveal melanoma who were treated with iodine 125 plaque brachytherapy and vitrectomy with silicone oil with minimum 1-year follow-up were included. Control patients who underwent brachytherapy alone were matched for tumor size, location, and sex. Baseline patient and tumor characteristics and tumor response to radiation, final visual acuity, macular status, central macular thickness by ocular coherence tomography (OCT), cataract progression, and metastasis at last follow-up visit were compared. Surgical complications were also determined. Results: Twenty case patients met the inclusion criteria. The average follow-up time was 22.1 months in case patients and 19.4 months in control patients. The final logMAR vision was 0.81 in case patients and 1.1 in control patients (P=.071); 8 case patients and 16 control patients had abnormal macular findings (P=.011); and the average central macular thickness by OCT was 293.2 μm in case patients and 408.5 μm in control patients (P=.016). Eleven case patients (55%) and 1 control patient (5%) had required cataract surgery at last follow-up (P=.002). Four patients in the case group and 1 patient in the control group experienced metastasis (P=.18). Among the cases, intraoperative retinal tear occurred in 3 patients; total serous retinal detachment and macular hole developed in 1 case patient each. There was no case of rhegmatogenous retinal detachment, treatment failure, or local tumor dissemination in case patients or control patients. Conclusions: With up to 3 years of clinical follow-up, silicone oil during brachytherapy

  11. Iodine 125 Brachytherapy With Vitrectomy and Silicone Oil in the Treatment of Uveal Melanoma: 1-to-1 Matched Case-Control Series

    Energy Technology Data Exchange (ETDEWEB)

    McCannel, Tara A., E-mail: TMcCannel@jsei.ucla.edu; McCannel, Colin A.

    2014-06-01

    Purpose: We initially reported the radiation-attenuating effect of silicone oil 1000 centistokes for iodine 125. The purpose of this report was to compare the clinical outcomes in case patients who had iodine 125 brachytherapy with vitrectomy and silicone oil 1000 centistokes with the outcomes in matched control patients who underwent brachytherapy alone. Methods and Materials: Consecutive patients with uveal melanoma who were treated with iodine 125 plaque brachytherapy and vitrectomy with silicone oil with minimum 1-year follow-up were included. Control patients who underwent brachytherapy alone were matched for tumor size, location, and sex. Baseline patient and tumor characteristics and tumor response to radiation, final visual acuity, macular status, central macular thickness by ocular coherence tomography (OCT), cataract progression, and metastasis at last follow-up visit were compared. Surgical complications were also determined. Results: Twenty case patients met the inclusion criteria. The average follow-up time was 22.1 months in case patients and 19.4 months in control patients. The final logMAR vision was 0.81 in case patients and 1.1 in control patients (P=.071); 8 case patients and 16 control patients had abnormal macular findings (P=.011); and the average central macular thickness by OCT was 293.2 μm in case patients and 408.5 μm in control patients (P=.016). Eleven case patients (55%) and 1 control patient (5%) had required cataract surgery at last follow-up (P=.002). Four patients in the case group and 1 patient in the control group experienced metastasis (P=.18). Among the cases, intraoperative retinal tear occurred in 3 patients; total serous retinal detachment and macular hole developed in 1 case patient each. There was no case of rhegmatogenous retinal detachment, treatment failure, or local tumor dissemination in case patients or control patients. Conclusions: With up to 3 years of clinical follow-up, silicone oil during brachytherapy

  12. Monte Carlo dosimetry for 125I and 103Pd eye plaque brachytherapy

    International Nuclear Information System (INIS)

    Thomson, R. M.; Taylor, R. E. P.; Rogers, D. W. O.

    2008-01-01

    A Monte Carlo study of dosimetry for eye plaque brachytherapy is performed. BrachyDose, an EGSnrc user code which makes use of Yegin's multi-geometry package, is used to fully model 125 I (model 6711) and 103 Pd (model 200) brachytherapy seeds and the standardized plaques of the Collaborative Ocular Melanoma Study (COMS). Three-dimensional dose distributions in the eye region are obtained. In general, dose to water is scored; however, the implications of replacing water with eye tissues are explored. The effect of the gold alloy (Modulay) backing is investigated and the dose is found to be sensitive to the elemental composition of the backing. The presence of the silicone polymer (Silastic) seed carrier results in substantial dose decreases relative to water, particularly for 103 Pd. For a 20 mm plaque with a Modulay backing and Silastic insert, fully loaded with 24 seeds, the dose decrease relative to water is of the order of 14% for 125 I and 20% for 103 Pd at a distance of 1 cm from the inner sclera along the plaque's central axis. For the configurations of seeds used in COMS plaques, interseed attenuation is a small effect within the eye region. The introduction of an air interface results in a dose reduction in its vicinity which depends on the plaque's position within the eye and the radionuclide. Introducing bone in the eye's vicinity also causes dose reductions. The dose distributions in the eye for the two different radionuclides are compared and, for the same prescription dose, 103 Pd generally offers a lower dose to critical normal structures. BrachyDose is sufficiently fast to allow full Monte Carlo dose calculations for routine clinical treatment planning.

  13. COMS eye plaque brachytherapy dosimetry simulations for 103Pd, 125I, and 131Cs

    International Nuclear Information System (INIS)

    Melhus, Christopher S.; Rivard, Mark J.

    2008-01-01

    Monte Carlo (MC) simulations were performed to estimate brachytherapy dose distributions for Collaborative Ocular Melanoma Study (COMS) eye plaques. Brachytherapy seed models 200, 6711, and CS-1 Rev2 carrying 103 Pd, 125 I, and 131 Cs radionuclides, respectively, were modeled and benchmarked against previously published values. Calculated dose rate constants MC Λ were 0.684, 0.924, and 1.052 cGy h -1 U -1 (±2.6%, k=1 uncertainty) for models 200, 6711, and CS-1 Rev2, respectively. The seeds were distributed into 10, 12, 14, 16, 18, 20, and 22 mm-diameter COMS eye plaques. Simulations were performed in both heterogeneous and homogeneous environments, where the latter were in-water and the former included the silastic seed carrier insert and gold-alloy plaque. MC-based homogenous central axis dose distributions agreed within 2%±1% (±1 s.d.) to hand-calculated values. For heterogeneous simulations, notable photon attenuation was observed, with dose reduction at 5 mm of 19%, 11%, and 9% for 103 Pd, 125 I, and 131 Cs, respectively. A depth-dependent correction factor was derived to correct homogenous central-axis dose distributions for plaque component heterogeneities, which were found to be significant at short radial distances

  14. Permanent interstitial implantation of 125Iodine seed for thoracic malignant tumors

    International Nuclear Information System (INIS)

    Xu Zhongheng; Qian Yongyue; Wu Jinchang; Liu Zengli

    2002-01-01

    Objective: To observe effect of 125 Iodine sed on interstitial brachytherapy of patient with thoracic malignant tumor. Methods: 125 Iodine seed were inserted into the target tissue and permanent left there for brachytherapy in 6 cases of thoracic malignant tumors, which including lung cancer, Pancoast's tumour, mediastinal malignant schwannoma. Results: All cases were rehabilitated shortly after operation. The implanted lesions remained controlled now and in dead patients. No radiation-related and 125 Iodine seed-related complications occurred. Conclusion: Brachytherapy by implantation of 125 Iodine seeds of remained tumor tissue in patients with thoracic malignant tumor after operation has a satisfactory outcome. This therapy can control local recurrent of thoracic malignant tumor. But the results in long term should be studied further

  15. Assessment of the risks associated with Iodine-125 handling production sources for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Daiane C.B.; Rostelato, Maria Elisa C.; Vicente, Roberto; Zeituni, Carlos A.; Tiezzi, Rodrigo; Costa, Osvaldo L.; Souza, Carla D.; Peleias Junior, Fernando S.; Rodrigues, Bruna T.; Souza, Anderson S.; Batista, Talita Q.; Melo, Emerson R.; Camargo, Anderson R., E-mail: dcsouza@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Karam Junior, Dib, E-mail: dib.karam@usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil)

    2015-07-01

    In Brazil, prostate cancer is the second most frequent disease, with an estimated 68,800 new cases in 2013. This type of cancer can be treated with brachytherapy, which uses sealed sources of Iodine-125 implanted permanently in the prostate. These sources are currently imported at a high cost, making public treatment in large scale impractical. To reduce costs and to meet domestic demand, the laboratory for production of brachytherapy sources at the Nuclear and Energy Research Institute (IPEN) is currently nationalizing the production of this radioisotope. Iodine is quite volatile making the handling of its radioactive isotopes potentially dangerous. The aim of this paper is to evaluate the risks to which workers are exposed during the production and handling of the sources. The research method consisted initially of a literature review on the toxicity of iodine, intake limits, related physical risks, handling of accidents, generation of radioactive wastes, etc. The results allowed for establishing safety and radioprotection policies in order to ensure efficient and safe production in all stages and the implementation of good laboratory practices. (author)

  16. Assessment of the risks associated with Iodine-125 handling production sources for brachytherapy

    International Nuclear Information System (INIS)

    Souza, Daiane C.B.; Rostelato, Maria Elisa C.; Vicente, Roberto; Zeituni, Carlos A.; Tiezzi, Rodrigo; Costa, Osvaldo L.; Souza, Carla D.; Peleias Junior, Fernando S.; Rodrigues, Bruna T.; Souza, Anderson S.; Batista, Talita Q.; Melo, Emerson R.; Camargo, Anderson R.; Karam Junior, Dib

    2015-01-01

    In Brazil, prostate cancer is the second most frequent disease, with an estimated 68,800 new cases in 2013. This type of cancer can be treated with brachytherapy, which uses sealed sources of Iodine-125 implanted permanently in the prostate. These sources are currently imported at a high cost, making public treatment in large scale impractical. To reduce costs and to meet domestic demand, the laboratory for production of brachytherapy sources at the Nuclear and Energy Research Institute (IPEN) is currently nationalizing the production of this radioisotope. Iodine is quite volatile making the handling of its radioactive isotopes potentially dangerous. The aim of this paper is to evaluate the risks to which workers are exposed during the production and handling of the sources. The research method consisted initially of a literature review on the toxicity of iodine, intake limits, related physical risks, handling of accidents, generation of radioactive wastes, etc. The results allowed for establishing safety and radioprotection policies in order to ensure efficient and safe production in all stages and the implementation of good laboratory practices. (author)

  17. Automation system for quality control in manufacture of iodine-125 sealed sources used in brachytherapy

    International Nuclear Information System (INIS)

    Somessari, Samir L.; Feher, Anselmo; Sprenger, Francisco E.; Rostellato, Maria E.C.M.; Moura, Joao A.; Costa, Osvaldo L.; Calvo, Wilson A.P.

    2011-01-01

    The objective of this work is to develop an automation system for Quality Control in the production of Iodine-125 sealed sources, after undergoing the process of laser beam welding. These sources, also known as Iodine-125 seeds are used, successfully, in the treatment of cancer by brachytherapy, with low-dose rates. Each small seed is composed of a welded titanium capsule with 0.8 mm diameter and 4.5 mm in length, containing Iodine-125 adsorbed on an internal silver wire. The seeds are implanted in the human prostate to irradiate the tumor and treat the cancerous cells. The technology to automate the quality control system in the manufacture of Iodine-125 seeds consists in developing and associate mechanical parts, electronic components and pneumatic circuits to control machines and processes. The automation technology for Iodine-125 seed production developed in this work employs programmable logic controller, step motors, drivers of control, electrical-electronic interfaces, photoelectric sensors, interfaces of communication and software development. Industrial automation plays an important role in the production of Iodine-125 seeds, with higher productivity and high standard of quality, facilitating the implementation and operation of processes with good manufacturing practices. Nowadays, the Radiation Technology Center at IPEN-CNEN/SP imports and distributes 36,000 Iodine-125 seeds per year for clinics and hospitals in the whole country. However, the Brazilian potential market is of 8,000 Iodine-125 seeds per month. Therefore, the local production of these radioactive seeds has become a priority for the Institute, aiming to reduce the price and increase the supply to the population in Brazil. (author)

  18. Automation system for quality control in manufacture of iodine-125 sealed sources used in brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Somessari, Samir L.; Feher, Anselmo; Sprenger, Francisco E.; Rostellato, Maria E.C.M.; Moura, Joao A.; Costa, Osvaldo L.; Calvo, Wilson A.P., E-mail: somessar@ipen.b, E-mail: afeher@ipen.b, E-mail: sprenger@ipen.b, E-mail: elisaros@ipen.b, E-mail: olcosta@ipen.b, E-mail: wapcalvo@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The objective of this work is to develop an automation system for Quality Control in the production of Iodine-125 sealed sources, after undergoing the process of laser beam welding. These sources, also known as Iodine-125 seeds are used, successfully, in the treatment of cancer by brachytherapy, with low-dose rates. Each small seed is composed of a welded titanium capsule with 0.8 mm diameter and 4.5 mm in length, containing Iodine-125 adsorbed on an internal silver wire. The seeds are implanted in the human prostate to irradiate the tumor and treat the cancerous cells. The technology to automate the quality control system in the manufacture of Iodine-125 seeds consists in developing and associate mechanical parts, electronic components and pneumatic circuits to control machines and processes. The automation technology for Iodine-125 seed production developed in this work employs programmable logic controller, step motors, drivers of control, electrical-electronic interfaces, photoelectric sensors, interfaces of communication and software development. Industrial automation plays an important role in the production of Iodine-125 seeds, with higher productivity and high standard of quality, facilitating the implementation and operation of processes with good manufacturing practices. Nowadays, the Radiation Technology Center at IPEN-CNEN/SP imports and distributes 36,000 Iodine-125 seeds per year for clinics and hospitals in the whole country. However, the Brazilian potential market is of 8,000 Iodine-125 seeds per month. Therefore, the local production of these radioactive seeds has become a priority for the Institute, aiming to reduce the price and increase the supply to the population in Brazil. (author)

  19. Adjuvant iodine-125 brachytherapy for hepatocellular carcinoma after complete hepatectomy: a randomized controlled trial.

    Directory of Open Access Journals (Sweden)

    Kaiyun Chen

    Full Text Available BACKGROUND: Tumor recurrence is a major problem after curative resection of hepatocellular carcinoma (HCC. The current study evaluated the effects of adjuvant iodine-125 ((125I brachytherapy on postoperative recurrence of HCC. METHODOLOGY/PRINCIPAL FINDINGS: From July 2000 to June 2004, 68 HCC patients undergoing curative hepatectomy were randomly assigned into a (125I adjuvant brachytherapy group (n = 34 and a group of best care (n = 34. Patients in the (125I adjuvant brachytherapy group received (125I seed implantation on the raw surface of resection. Patients in the best care control group received identical treatments except for the (125I seed implantation. Time to recurrence (TTR and 1-, 3- and 5-year overall survival (OS were compared between the two groups. The follow-up ended in January 2010, and lasted for 7.7-106.4 months with a median of 47.6 months. TTR was significantly longer in the (125I group (mean of 60.0 months vs. 36.7 months in the control. The 1-, 3- and 5-year recurrence-free rates of the (125I group were 94.12%, 76.42%, and 73.65% vs. 88.24%, 50.00%, and 29.41% compared with the control group, respectively. The 1-, 3- and 5-year OS rates of the (125I group were 94.12%, 73.53%, and 55.88% vs. 88.24%, 52.94%, and 29.41% compared with the control group, respectively. The (125I brachytherapy decreased the risk of recurrence (HR = 0.310 and the risk of death (HR = 0.364. Most frequent adverse events in the (125I group included nausea, vomiting, arrhythmia, decreased white blood cell and/or platelet counts, and were generally mild and manageable. CONCLUSIONS/SIGNIFICANCE: Adjuvant (125I brachytherapy significantly prolonged TTR and increased the OS rate after curative resection of HCC. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ACTRN12610000081011.

  20. Study and parameters survey for iodine-125 source dosimetry to be applied in brachytherapy

    International Nuclear Information System (INIS)

    Moura, Eduardo Santana de

    2011-01-01

    The use of brachytherapy technique with iodine-125 seeds to prostate cancer treatment has been used for decades with good clinical outcomes. To aim the Brazilian population necessities, IPEN-CNEN/SP developed the iodine-125 seed prototype with national technology. The objectives of this work are the development and the study of dosimetric procedures associates with the experimental acquisition of the useful parameters for the iodine-125 dosimetric characterization and to evaluate if the developed procedures, in this work, have the basic conditions to determinate the dosimetric analysis, that are fundamental for clinical procedures. The dosimeters selected for the analysis are the TLD-100 (LiF:Mg,Ti), initially these dosimeters were submitted for two selection steps to choose the dosimeters more reproducible for the dosimetric analysis. The two steps were the selection by the mass of the dosimeters and the reproducibility after four irradiation series in a Cobalt-60 irradiator (CTR-IPEN). Afterwards these steps, the dosimeters were irradiated in linear accelerator with 6 MV energy (Service of Radiotherapy - Hospital Israelita Albert Einstein) to yield the individual calibration factors to each dosimeter. After, the dosimeters were used to the irradiations with iodine-125 seed, 6711 model, (GE-Healthcare). The irradiations and others analysis with iodine-125 seeds yield the useful values for the determination of the parameters suggested by the AAPM (American Association of Physicists in Medicine): constant of dose rate, geometry function, dose radial function and anisotropy function. The results showed good agreement with the values published by the literature, for the same iodine- 125 model, this fact confirms that the realized parameters will be able to be used for the IPEN-CNEN iodine-125 seeds dosimetry and quality control. (author)

  1. Development of an automation system for iodine-125 brachytherapy seed production by ND:YAG laser welding

    International Nuclear Information System (INIS)

    Somessari, Samir L.; Feher, Anselmo; Sprenger, Francisco E.; Rostellato, Maria Elisa C.M.; Costa, Fabio E.; Calvo, Wilson A.P.

    2009-01-01

    The aim of this work is to develop an automation system for iodine-125 radioactive seed production by Nd:YAG laser welding, which has been used successfully in low dose rate brachytherapy treatment. This small seed consists of a welded titanium capsule, with 0.8 mm in diameter and 4.5 mm in length, containing iodine-125 adsorbed onto a silver rod. The iodine-125 seeds are implanted into the human prostate to irradiate the tumor for cancer treatment. Nowadays, the Radiation Technology Center, at IPEN-CNEN/SP imports and distributes 36,000 iodine-125 seeds per year, for the clinics and hospitals in the country. However, the Brazilian market potential is now over 8,000 iodine-125 seeds per month. The local production of these iodine-125 radioactive sources became a priority for the Institute, in order to reduce the price and the problems of prostate cancer management. It will permit to spread their use to a larger number of patients in Brazil. On the other hand, the industrial automation plays an important role for iodine-125 seeds in order to increase the productivity, with high quality and assurance, avoiding human factors, implementing and operating with good manufacturing practices. The technology consists of appliance electronic and electro-mechanical parts and components to control machines and processes. The automation system technology for iodine-125 seed production developed in this work was mainly assembled employing a Programmable Logic Controller, a stepper motor, an Nd:YAG laser welding machine and a supervisory. (author)

  2. Development of an automation system for iodine-125 brachytherapy seed production by (Nd:YAG) laser welding

    International Nuclear Information System (INIS)

    Somessari, Samir Luiz

    2010-01-01

    The aim of this work is to develop an automation system for iodine-125 radioactive seed production by (Nd:YAG) laser welding, which has been used successfully in Low Dose Rate (LDR) brachytherapy treatment. This small seed consists of a welded titanium capsule, with 0.8mm in diameter and 4.5mm in length, containing iodine-125 adsorbed onto a silver rod. The iodine-125 seeds are implanted into the human prostate to irradiate the tumor for cancer treatment. Nowadays, the Radiation Technology Center, at IPEN-CNEN/SP imports and distributes 36,000 iodine-125 seeds per year, for the clinics and hospitals in the country. However, the Brazilian market potential is now over 8,000 iodine-125 seeds per month. The local production of these iodine-125 radioactive sources becomes a priority for the Institute, in order to reduce the price and the problems of prostate cancer management. It will permit to spread their use to a largest number of patients in Brazil. On the other hand, the industrial automation plays an important role for iodine-125 seeds in order to increase the productivity, with high quality and assurance, avoiding human factors, implementing and operating with Good Manufacturing Practices (GMP). The technology consists of appliance electronic and electro-mechanical parts and components to control machines and processes. The automation system technology for iodine-125 seed production developed in this work was mainly assembled employing Programmable Logic Controller (PLC), stepper motors, drivers, (Nd:YAG) laser welding machine, photoelectric sensors and supervisory. (author)

  3. Development of an automation system for Iodine-125 brachytherapy seed encapsulated by Nd:YAG laser welding

    International Nuclear Information System (INIS)

    Somessari, S.L.; Feher, A.; Sprenger, F.E.; Rostelato, M.E.C.M.; Costa, F.E. da; Calvo, W.A.P.

    2011-01-01

    The aim of this work is to develop an automation system for iodine-125 radioactive seed production by Nd:YAG laser welding, which has been used successfully in low dose rate (LDR) brachytherapy treatment. This small seed consists of a welded titanium capsule, with 0.8 mm in diameter and 4.5 mm in length, containing iodine-125 adsorbed onto a silver rod. The iodine-125 seeds are implanted into the human prostate to irradiate the tumor for cancer treatment. Nowadays, the Radiation Technology Center, at Institute for Nuclear and Energy Research, Sao Paulo, Brazil (IPEN-CNEN/SP) imports and distributes 36,000 iodine-125 seeds per year, for the clinics and hospitals in the country. However, the Brazilian market potential is now over 8,000 iodine-125 seeds per month. The local production of these iodine-125 radioactive sources became a priority for the Institute, in order to reduce the price and the problems of prostate cancer management. It will permit to spread their use to a larger number of patients in Brazil. On the other hand, the industrial automation plays an important role for iodine-125 seeds in order to increase the productivity, with high quality and assurance, avoiding human factors, implementing and operating with good manufacturing practices (GMP). The technology consists of appliance electronic and electro-mechanical parts and components to control machines and processes. The automation system technology for iodine-125 seed production developed in this work was mainly assembled employing a programmable logic controller (PLC), a stepper motor, an Nd:YAG laser welding machine and a supervisory. The statistical repeatability of correctly encapsulated sealed sources with this automation system is greater than 95%. (authors)

  4. Brachytherapy with 125-Iodine sources: transport and radiation protection

    International Nuclear Information System (INIS)

    Souza, Carla D.; Zeituni, Carlos A.; Moura, Joao A.; Moura, Eduardo S.; Nagatomi, Helio R.; Feher, Anselmo; Hilario, Katia F.; Rostelato, Maria Elisa C.M.

    2009-01-01

    The estimates for the year 2009 show that 466,730 new cancer cases will occur in Brazil. Prostate cancer is the second most incident type. Brachytherapy, a type of radiotherapy, with Iodine-125 sources are an important form of treatment for this kind of cancer. The Instituto de Pesquisas Energeticas e Nucleares (IPEN) created a project to develop a national prototype of these sources and is implementing a facility for local production. The seeds manufacture in Brazil will allow to diminish the treatment cost and make it possible for a larger number of patients. While the laboratory is not ready, the IPEN import and it distributes seeds. This work aim is to present and evaluate the transport procedures and the radiological protection applied to imported sources in order to assist the procedures for the new laboratory implementation. Before sending to hospitals, the seeds are packed by a radioprotector supervisor, in accordance with CNEN NE 5.01 standard 'Radioactive Material Transport'. Despite Iodine-125 presents low energy photons, around 29 keV, local and personal dosimeters are used during the transport process, as described in CNEN NN 3.01 standard 'Radiological Protection Basic Guideline'. All the results show no contamination and very low exposure, proving the method to be valid. The transport procedure used is correct, according to the regulations. As an result of this work, a new dosimeter should be installed and evaluate in future study. (author)

  5. Outcomes following iodine-125 prostate brachytherapy with or without neoadjuvant androgen deprivation

    International Nuclear Information System (INIS)

    Ohashi, Toshio; Yorozu, Atsunori; Saito, Shiro; Momma, Tetsuo; Toya, Kazuhito; Nishiyama, Toru; Yamashita, Shoji; Shiraishi, Yutaka; Shigematsu, Naoyuki

    2013-01-01

    Purpose: To report the biochemical failure-free survival (BFFS), cause-specific survival (CSS), and overall survival (OS) outcomes of patients treated with iodine-125 (I-125) brachytherapy for clinically localized prostate cancer. Methods and materials: Between 2003 and 2009, I-125 permanent prostate brachytherapy without supplemental external-beam radiotherapy was performed for 663 patients with low-risk and low-tier intermediate-risk (defined as organ-confined disease, PSA <10 ng/mL, and Gleason score 3 + 4 with biopsy positive core rate <33%) prostate cancer. Early in the study period, the preplanning method was used in the first 104 patients, and later the real-time planning method was used. Biochemical failure was determined using the American Society for Therapeutic Radiology Oncology (ASTRO) and Phoenix definitions. Results: The 7-year BFFS rates for the ASTRO and Phoenix definitions were 96.1% and 95.9%, respectively. The corresponding BFFS rates by risk group were 97.6% and 96.7% for low-risk, and 91.8% and 93.6% for low-tier intermediate-risk disease (p = 0.007 and 0.08, respectively). The median times to biochemical failure in those who failed were 29.5 and 43.9 months according to the ASTRO and Phoenix definitions, respectively. The 7-year CSS and OS were 99.1% and 96.4%. There was no significant difference in CSS or OS between the low-risk and low-tier intermediate-risk groups. In multivariate Cox regression analysis, risk group and prostate D90 were independent predictors of BFFS for the ASTRO definition, while only the prostate D90 was significant for the Phoenix definition. Conclusion: I-125 prostate brachytherapy results in excellent 7-year BFFS, CSS, and OS for low-risk and low-tier intermediate-risk prostate cancer

  6. Brazilian demand for Iodine-125 seeds in cancer treatment after a decade of medical procedures

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Osvaldo L. da; Souza, Daiane C.B. de; Feher, Anselmo; Moura, João A.; Souza, Carla D.; Oliveira, Henrique B. de; Peleiras Junior, Fernando S.; Zeituni, CArlos A.; Rostelaro, Maria E.C.M., E-mail: olcosta@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Iodine-125 and palladium-103 are radionuclides employed to made medical devices used in cancer treatment known as brachytherapy seeds. These radioactive sealed sources are applied in brain and ophthalmic cancer as a temporary implant to irradiate the tumor and in permanent implants to prostatic cancer. Brazilian Nuclear Energy Commission (CNEN) has the monopoly in Brazil of iodine-125 brachytherapy seeds distribution which is executed for Nuclear and Energy Research Institute (IPEN-CNEN/SP). Along a decade of use in Brazil more than 240 thousand seeds were implanted in patients or used to treat cancer tumors. In this article the Brazilian demand for iodine-125 brachytherapy seeds is analyzed. The demand behavior along a decade of using loose, strand, ophthalmic and brain brachytherapy seeds are shown. The annual quantity of seeds demanded by Brazil has dropped since 2012. The loose seeds which represented until 30% from total brachytherapy seeds used in Brazil decreased to less than 3%. The brain brachytherapy seeds had low demand along the decade and presented zero demand in several years. Concurrent treatment techniques are listed and main trends are discussed. The influence of Brazilian economic crisis and the demand behavior of the main hospitals and clinics that use Iodine-125 brachytherapy are shown. (author)

  7. Brazilian demand for Iodine-125 seeds in cancer treatment after a decade of medical procedures

    International Nuclear Information System (INIS)

    Costa, Osvaldo L. da; Souza, Daiane C.B. de; Feher, Anselmo; Moura, João A.; Souza, Carla D.; Oliveira, Henrique B. de; Peleiras Junior, Fernando S.; Zeituni, CArlos A.; Rostelaro, Maria E.C.M.

    2017-01-01

    Iodine-125 and palladium-103 are radionuclides employed to made medical devices used in cancer treatment known as brachytherapy seeds. These radioactive sealed sources are applied in brain and ophthalmic cancer as a temporary implant to irradiate the tumor and in permanent implants to prostatic cancer. Brazilian Nuclear Energy Commission (CNEN) has the monopoly in Brazil of iodine-125 brachytherapy seeds distribution which is executed for Nuclear and Energy Research Institute (IPEN-CNEN/SP). Along a decade of use in Brazil more than 240 thousand seeds were implanted in patients or used to treat cancer tumors. In this article the Brazilian demand for iodine-125 brachytherapy seeds is analyzed. The demand behavior along a decade of using loose, strand, ophthalmic and brain brachytherapy seeds are shown. The annual quantity of seeds demanded by Brazil has dropped since 2012. The loose seeds which represented until 30% from total brachytherapy seeds used in Brazil decreased to less than 3%. The brain brachytherapy seeds had low demand along the decade and presented zero demand in several years. Concurrent treatment techniques are listed and main trends are discussed. The influence of Brazilian economic crisis and the demand behavior of the main hospitals and clinics that use Iodine-125 brachytherapy are shown. (author)

  8. Iodine-125 thin seeds decrease prostate swelling during transperineal interstitial permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Beydoun, Nadine; Bucci, Joseph A.; Chin, Yaw S.; Malouf, David

    2014-01-01

    Prostate swelling following seed implantation is a well-recognised phenomenon. The purpose of this intervention was to assess whether using thinner seeds reduces post-implant swelling with permanent prostate brachytherapy. Eighteen consecutive patients eligible for prostate seed brachytherapy underwent seed implantation using iodine-125 (I-125) thin seeds. Operative time, dosimetry, prostate swelling and toxicity were assessed and compared with standard I-125 stranded seed controls, sourced from the department's brachytherapy database. A learning curve was noted with the thin seeds in terms of greater bending and deviation of needles from their intended path. This translated into significantly longer total operative time (88 vs 103 minutes; P=0.009, 95% confidence interval (CI) 4.1-24.3) and time per needle insertion (2.6 vs 3.7 minutes; P<0.001, 95% CI 0.5-1.3) for the thin seeds. Day 30 prostate volumes were significantly smaller in the thin seed group compared with standard seeds (40.9cc vs 46.8cc; P=0.001, 95% CI 1.5-5.6). The ratio of preoperative transrectal ultrasound to day 30 post-implant CT volume was also smaller in the thin seed group (1.2±0.1 for standard seeds vs 1.1±0.1 for thin seeds). Post-implant dosimetric parameters were comparable for both groups. No significant differences were seen in acute urinary morbidity or quality of life between the two groups. I-125 thin seeds are associated with an initial learning curve, with longer operative time, even for experienced brachytherapists. The significant reduction in day 30 prostate volumes with the thin seeds has useful implications in terms of optimising dose coverage to the prostate in the early period post-implantation, as well as improving the accuracy of post-implant dosimetric assessments.

  9. Dosimetric study in iodine-125 seeds for brachytherapy application

    International Nuclear Information System (INIS)

    Zeituni, Carlos Alberto

    2008-01-01

    The demand for iodine-125 seeds for use in brachytherapy treatments has experienced an increase along recent years in Brazil and all over the world. All iodine-125 seed must have its operational parameters measured and/or calculated every time changes in the production process are carried out. A complete dosimetric measurement is very expensive, and it is recommended that this procedure must be repeated at least once a year. Thus, this work developed a methodology for the entire dosimetric process. This methodology is based on the scarce information available in the literature, once almost all the methodology used in large industrial laboratories is commercial secret. The proposed methodology was tested using seeds of Amersham-Oncura-Ge Healthcare, which is the largest seed manufactory in the world. In this new methodology, an automatic reader was employed in order to reduce the time required in the selection process of the TLD-100 dosimeters used and a postprocessing of the obtained spectra was carried out. A total of 142 dosimeters were used and only 29 have been selected using the new methodology. Measurements were performed using slabs of Solid Water RW1 to simulate measuring in the 'water', using three different experimental apparatus and each measurement was repeated at least three times. The TLD-100 calibration was performed using a Dermopan II - Siemens. The measured values showed a good agreement with the ones available in the literature. Finally, these measured values were compared with calculated ones obtained by a semiempirical simulation program, showing a good agreement and, therefore, demonstrating the validity of the proposed methodology regarding dosimetric calculations. (author)

  10. Ropes eye plaque brachytherapy dosimetry for two models of 103Pd seeds

    International Nuclear Information System (INIS)

    Saidi, P.; Sadeghi, M.; Shirazi, A.; Tenreiro, C.

    2011-01-01

    Full text: Brachytherapy dose distributions are calculated for I5 m m ROPES eye plaque loaded with model Theragenics200 and IR06-103Pd seeds. The effects of stainless steel backing and Acrylic insert on dose distribution along the central axis of the eye plaque and at critical ocular structure are investigated. Monte Carlo simulation was carried out with the Version 5 of the MCNP. The dose at critical ocular structure by considering the eye composition was calculated. Results are compared with the calculated data for CaMS eye plaque loaded with Theragenics200 palladium-103 seeds and model 6711 iodine-125 seed. The air kerma strength of the IR06- 103Pd seed to deliver 85 Gy in apex of tumor in water medium was calculated to be 4.10 U/seed. Along the central axis of stainless steel plaque loaded with new 103Pd seeds in Acrylic insert, the dose reduction relative to water is 6.9% at 5 mm (apex). Removal of the Acrylic insert from the plaque (replacing with water) did not make significantly difference in dose reduction results (O.2%). The presence of the stainless steel backing results in dose enhancement near the plaque relative to water. Doses at points of interest are higher for ROPES eye plaque when compared to CaMS eye plaque. The dosimetric parameters calculated in this work for the new palladium seed, showed that in dosimetry point of view, the IR06-103Pd seed is suitable for use in brachytherapy. The effect of Acrylic insert on dose distribution is negligible and the main effect on dose reduction is due to the presence of stainless steel plaque backing. (author)

  11. Multivariable model development and internal validation for prostate cancer specific survival and overall survival after whole-gland salvage Iodine-125 prostate brachytherapy

    NARCIS (Netherlands)

    Peters, Max; van der Voort van Zyp, Jochem R N; Moerland, Marinus A; Hoekstra, Carel J; van de Pol, Sandrine; Westendorp, Hendrik; Maenhout, Metha; Kattevilder, Rob; Verkooijen, Helena M; van Rossum, Peter S N; Ahmed, Hashim U; Shah, Taimur T; Emberton, Mark; van Vulpen, Marco

    BACKGROUND: Whole-gland salvage Iodine-125-brachytherapy is a potentially curative treatment strategy for localised prostate cancer (PCa) recurrences after radiotherapy. Prognostic factors influencing PCa-specific and overall survival (PCaSS & OS) are not known. The objective of this study was to

  12. Radiation complications and tumor control after 125I plaque brachytherapy for ocular melanoma

    International Nuclear Information System (INIS)

    Jensen, Ashley W.; Petersen, Ivy A.; Kline, Robert W.; Stafford, Scott L.; Schomberg, Paula J.; Robertson, Dennis M.

    2005-01-01

    Purpose: To determine the outcome of 125 I plaque brachytherapy at our institution and identify the risk factors associated with the development of radiation complications, tumor recurrence, and metastasis. Patients and Methods: From 1986 to 2000, 156 patients underwent 125 I episcleral plaque (COMS design) application for the treatment of ocular melanoma. Chart analysis of follow-up ophthalmologic appointments assessed the incidence of ocular side effects after therapy. Statistical analysis assessed outcomes and significant influencing factors. Results: With a median follow-up of 6.2 years, the 5-year overall survival was 83%. The 5-year disease-specific survival was 91%. Initial local control at 5 years was 92%, with 100% ultimate local control after secondary therapy that included 9 enucleations. The risk of metastasis was 10% at 5 years and 27% at 10 years. Vision stayed the same or improved in 25% of patients, and 44% of patients maintained visual acuity better than 20/200. Thirteen percent of patients experienced chronic pain or discomfort in the treated eye. Dose rates to the tumor apex greater than 90 to 100 cGy/h were associated with increased systemic control but worse radiation toxicity. Conclusion: Patients in our series experienced excellent local tumor control. Higher dose rates to the tumor apex were associated with reduced rates of distant metastases but worse ocular function

  13. The development of a human eye model for ophthalmic iodine-125 brachytherapy dosimetry

    International Nuclear Information System (INIS)

    Mourao, A.P.; Campos, T.P.R.

    2008-01-01

    Full text: Radiotherapy is used to treat malign tumors. Radiotherapy is an alternative to enucleation in ocular tumors. However, the irradiation of ocular region can bring damages due high doses, mainly in the crystalline lens and in the bone tissue in growth phase. Brachytherapy instead of teletherapy looks for reducing doses in the crystalline lens and the adjacent tissues of the ocular globe (orbital region), minimizing side effects. Herein, some encapsulated radioisotopes in radioactive seeds applied to the ocular brachytherapy are available. Thus, a three-dimensional computational voxel model of the ocular region with its heterogeneous tissues, globe and adjacent tissues is developed. This computational model is used to simulate orbital irradiation with radioactive seeds positioned on the sclera surface through the MCNP5 code. The computational simulation allows evaluating how doses are spatially distributed in the orbital volume in treatments with the radioactive seeds of iodine-125. Therefore, the results allow comparing the spatial doses distribution obtained through the MCNP5 simulation for those two distinct types of radioactive seeds. Bench markets from literature validates the proposed simulations. (author)

  14. Dosimetric and Late Radiation Toxicity Comparison Between Iodine-125 Brachytherapy and Stereotactic Radiation Therapy for Juxtapapillary Choroidal Melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Krema, Hatem, E-mail: htmkrm19@yahoo.com [Department of Ocular Oncology, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Heydarian, Mostafa [Department of Radiation Medicine, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Beiki-Ardakani, Akbar [Department of Radiation Oncology, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Weisbrod, Daniel [Department of Ocular Oncology, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Xu, Wei [Department of Biostatistics, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Laperriere, Normand J.; Sahgal, Arjun [Department of Radiation Oncology, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada)

    2013-07-01

    Purpose: To compare the dose distributions and late radiation toxicities for {sup 125}I brachytherapy (IBT) and stereotactic radiation therapy (SRT) in the treatment of juxtapapillary choroidal melanoma. Methods: Ninety-four consecutive patients with juxtapapillary melanoma were reviewed: 30 have been treated with IBT and 64 with SRT. Iodine-125 brachytherapy cases were modeled with plaque simulator software for dosimetric analysis. The SRT dosimetric data were obtained from the Radionics XKnife RT3 software. Mean doses at predetermined intraocular points were calculated. Kaplan-Meier estimates determined the actuarial rates of late toxicities, and the log–rank test compared the estimates. Results: The median follow-up was 46 months in both cohorts. The 2 cohorts were balanced with respect to pretreatment clinical and tumor characteristics. Comparisons of radiation toxicity rates between the IBT and SRT cohorts yielded actuarial rates at 50 months for cataracts of 62% and 75% (P=.1), for neovascular glaucoma 8% and 47% (P=.002), for radiation retinopathy 59% and 89% (P=.0001), and for radiation papillopathy 39% and 74% (P=.003), respectively. Dosimetric comparisons between the IBT and SRT cohorts yielded mean doses of 12.8 and 14.1 Gy (P=.56) for the lens center, 17.6 and 19.7 Gy (P=.44) for the lens posterior pole, 13.9 and 10.8 Gy (P=.30) for the ciliary body, 61.9 and 69.7 Gy (P=.03) for optic disc center, and 48.9 and 60.1 Gy (P<.0001) for retina at 5-mm distance from tumor margin, respectively. Conclusions: Late radiation-induced toxicities were greater with SRT, which is secondary to the high-dose exposure inherent to the technique as compared with IBT. When technically feasible, IBT is preferred to treat juxtapapillary choroidal melanoma.

  15. Iodine-125 seeds for cancer treatment

    Energy Technology Data Exchange (ETDEWEB)

    Rostelato, Maria E.C.M.; Zeituni, Carlos A.; Feher, Anselmo; Moura, Joao A.; Moura, Eduardo S.; Nagatomi, Helio R.; Manzoli, Jose E.; Souza, Carla D., E-mail: elisaros@ipen.b, E-mail: czeituni@pobox.co, E-mail: afeher@ipen.b, E-mail: jmoura31@yahoo.com.b, E-mail: esmoura@ipen.b, E-mail: hrnagato@ipen.b, E-mail: jemanzoli@ipen.b, E-mail: cdsouza@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Karam, Dib, E-mail: dib.karan@usp.b [Universidade de Sao Paulo (USP), SP (Brazil). Escola de Artes, Ciencias e Humanidades

    2009-07-01

    In Brazil, cancer has become one of the major public health problems. An estimate by the Health Ministry showed that 466,430 people had the disease in the country in 2008. The prostate cancer is the second largest death cause among men. The National Institute of Cancer estimated the occurrence of 50,000 new cases for 2009. Some of these patients are treated with Brachytherapy, using Iodine-125 seeds. By this technique, small seeds with Iodine-125, a radioactive material, are implanted in the prostate. The advantages of radioactive seed implants are the preservation of healthy tissues and organs near the prostate, besides the low rate of impotence and urinary incontinence. The Energy and Nuclear Research Institute - IPEN, which belongs to the Nuclear Energy National Commission - CNEN, established a program for the development of the technique and production of Iodine-125 seeds in Brazil. The estimate for the 125-Iodine seeds demand is of 8,000 seeds/month and the laboratory to be implanted will need this production capacity. The purpose of this paper is to explain the project status and show some data about the seeds used in the country. The project will be divided in two phases: technological development of a prototype and a laboratory implementation for the seeds production. (author)

  16. Use of brachytherapy with permanent implants of iodine-125 in localized prostate cancer

    International Nuclear Information System (INIS)

    Bladou, F.; Serment, G.; Salem, N.; Simonian, M.; Rosello, R.; Ternier, F.

    2002-01-01

    Approximately 15,000 cases of early stage prostate cancer T1 and T2 are diagnosed every year in France by testing for PSA and performing prostatic biopsies. The treatment of these localized forms is based in most cases on radical prostatectomy or nn external beam radiotherapy. Although the ontological results obtained by these two therapeutic methods are satisfactory and equivalent in the long term, the side effects can be important. For a number of years, trans-perineal brachytherapy using permanent implants of iodine -125 or palladium-103 has proved itself as an alternative therapy with equivalent medium to long-term results. The low urinary, digestive and sexual side effects of prostate brachytherapy are important reasons for the enthusiasm among patients and the medical community for this therapy and the growing number of applications and centres which practice it. In September 1998 we started the prostate brachytherapy programmes- in Marseilles with close collaboration between the department of urology of the Hopital Salvator, and the departments of radiotherapy, medical imaging and medical physics of the Institut Paoli-Calmettes. To date, around 250 patients with localized adenocarcinoma of the prostate have benefited from this alternative therapy in our centre. Preliminary results, with a 3 year-follow-up, are comparable to results published in the literature by pioneer teams. (authors)

  17. Optimization of 125I ophthalmic plaque brachytherapy

    International Nuclear Information System (INIS)

    Astrahan, M.A.; Luxton, G.; Jozsef, G.; Liggett, P.E.; Petrovich, Z.

    1990-01-01

    Episcleral plaques containing 125 I sources are often used in the treatment of ocular melanoma. Within four years post-treatment, however, the majority of patients experience some visual loss due to radiation retinopathy. The high incidence of late complications suggests that careful treatment optimization may lead to improved outcome. The goal of optimization would be to reduce the magnitude of vision-limiting complications without compromising tumor control. We have developed a three-dimensional computer model for ophthalmic plaque therapy which permits us to explore the potential of various optimization strategies. One simple strategy which shows promise is to maximize the ratio of dose to the tumor apex (T) compared to dose to the macula (M). By modifying the parameters of source location, activity distribution, source orientation, and shielding we find that the calculated T:M ratio can be varied by a factor of 2 for a common plaque design and posterior tumor location. Margins and dose to the tumor volume remain essentially unchanged

  18. Development of an encapsulation method using plasma arc welding to produce iodine-125 seeds for brachytherapy

    International Nuclear Information System (INIS)

    Feher, Anselmo; Calvo, Wilson A.P.; Rostelato, Maria E.C.M.; Zeituni, Carlos A.; Somessari, Samir L.; Costa, Osvaldo L.; Moura, Joao A.; Moura, Eduardo S.; Souza, Carla D.; Rela, Paulo R.

    2011-01-01

    The prostate cancer, which is the second cause of death by cancer in men, overcome only by lung cancer is public health problem in Brazil. Brachytherapy is among the possible available treatments for prostate cancer, in which small seeds containing Iodine-125 radioisotope are implanted into the prostate gland. The seed consists of a titanium sealed capsule with 0.8 mm external diameter and 4.5 mm length, containing a central silver wire with adsorbed Iodine-125. The Plasma Arc Welding (PAW) is one of the viable techniques for sealing process. The equipment used in this technique is less costly than in other processes, such as, Laser Beam Welding (LBW). The main purpose of this work was the development of an encapsulation method using PAW. The development of this work has presented the following phases: cutting and cleaning titanium tube, determination of the welding parameters, development of a titanium tube holding device for PAW, sealed sources validation according to ISO 2919 - Sealed Radioactive Sources - General Requirements and Classification, and metallographic assays. The developed procedure to seal Iodine-125 seeds using PAW has shown high efficiency, satisfying all the established requirements of ISO 2919. The results obtained in this work will give the possibility to establish a routine production process according to the orientations presented in resolution RDC 17 - Good Manufacturing Practices to Medical Products defined by the ANVISA - National Agency of Sanitary Surveillance. (author)

  19. Development of an encapsulation method using plasma arc welding to produce iodine-125 seeds for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Feher, Anselmo; Calvo, Wilson A.P.; Rostelato, Maria E.C.M.; Zeituni, Carlos A.; Somessari, Samir L.; Costa, Osvaldo L.; Moura, Joao A.; Moura, Eduardo S.; Souza, Carla D.; Rela, Paulo R., E-mail: afeher@ipen.b, E-mail: wapcalvo@ipen.b, E-mail: elisaros@ipen.b, E-mail: somessar@ipen.b, E-mail: olcosta@ipen.b, E-mail: esmoura@ipen.b, E-mail: cdsouza@ipen.b, E-mail: prela@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The prostate cancer, which is the second cause of death by cancer in men, overcome only by lung cancer is public health problem in Brazil. Brachytherapy is among the possible available treatments for prostate cancer, in which small seeds containing Iodine-125 radioisotope are implanted into the prostate gland. The seed consists of a titanium sealed capsule with 0.8 mm external diameter and 4.5 mm length, containing a central silver wire with adsorbed Iodine-125. The Plasma Arc Welding (PAW) is one of the viable techniques for sealing process. The equipment used in this technique is less costly than in other processes, such as, Laser Beam Welding (LBW). The main purpose of this work was the development of an encapsulation method using PAW. The development of this work has presented the following phases: cutting and cleaning titanium tube, determination of the welding parameters, development of a titanium tube holding device for PAW, sealed sources validation according to ISO 2919 - Sealed Radioactive Sources - General Requirements and Classification, and metallographic assays. The developed procedure to seal Iodine-125 seeds using PAW has shown high efficiency, satisfying all the established requirements of ISO 2919. The results obtained in this work will give the possibility to establish a routine production process according to the orientations presented in resolution RDC 17 - Good Manufacturing Practices to Medical Products defined by the ANVISA - National Agency of Sanitary Surveillance. (author)

  20. Study and parameters survey for iodine-125 source dosimetry to be applied in brachytherapy; Estudo e levantamentos de parametros para dosimetria de fontes de iodo-125 aplicadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo Santana de

    2011-07-01

    The use of brachytherapy technique with iodine-125 seeds to prostate cancer treatment has been used for decades with good clinical outcomes. To aim the Brazilian population necessities, IPEN-CNEN/SP developed the iodine-125 seed prototype with national technology. The objectives of this work are the development and the study of dosimetric procedures associates with the experimental acquisition of the useful parameters for the iodine-125 dosimetric characterization and to evaluate if the developed procedures, in this work, have the basic conditions to determinate the dosimetric analysis, that are fundamental for clinical procedures. The dosimeters selected for the analysis are the TLD-100 (LiF:Mg,Ti), initially these dosimeters were submitted for two selection steps to choose the dosimeters more reproducible for the dosimetric analysis. The two steps were the selection by the mass of the dosimeters and the reproducibility after four irradiation series in a Cobalt-60 irradiator (CTR-IPEN). Afterwards these steps, the dosimeters were irradiated in linear accelerator with 6 MV energy (Service of Radiotherapy - Hospital Israelita Albert Einstein) to yield the individual calibration factors to each dosimeter. After, the dosimeters were used to the irradiations with iodine-125 seed, 6711 model, (GE-Healthcare). The irradiations and others analysis with iodine-125 seeds yield the useful values for the determination of the parameters suggested by the AAPM (American Association of Physicists in Medicine): constant of dose rate, geometry function, dose radial function and anisotropy function. The results showed good agreement with the values published by the literature, for the same iodine- 125 model, this fact confirms that the realized parameters will be able to be used for the IPEN-CNEN iodine-125 seeds dosimetry and quality control. (author)

  1. Relationship between two year PSA nadir and biochemical recurrence in prostate cancer patients treated with iodine-125 brachytherapy

    Directory of Open Access Journals (Sweden)

    Carlos Antônio da Silva Franca

    2014-04-01

    Full Text Available Objective To evaluate the relationship between two year PSA nadir (PSAn after brachytherapy and biochemical recurrence rates in prostate cancer patients. Materials and Methods In the period from January 1998 to August 2007, 120 patients were treated with iodine-125 brachytherapy alone. The results analysis was based on the definition of biochemical recurrence according to the Phoenix Consensus. Results Biochemical control was observed in 86 patients (71.7%, and biochemical recurrence, in 34 (28.3%. Mean PSAn was 0.53 ng/ml. The mean follow-up was 98 months. The patients were divided into two groups: group 1, with two year PSAn < 0.5 ng/ml after brachytherapy (74 patients; 61.7%, and group 2, with two year PSAn ≥ 0.5 ng/ml after brachytherapy (46 patients; 38.3%. Group 1 presented biochemical recurrence in 15 patients (20.3%, and group 2, in 19 patients (43.2% (p < 0.02. The analysis of biochemical disease-free survival at seven years, stratified by the two groups, showed values of 80% and 64% (p < 0.02, respectively. Conclusion Levels of two year PSAn ≥ 0.5 ng/ml after brachytherapy are strongly correlated with a poor prognosis. This fact may help to identify patients at risk for disease recurrence.

  2. Optimization of sup 125 I ophthalmic plaque brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Astrahan, M.A.; Luxton, G.; Jozsef, G.; Liggett, P.E.; Petrovich, Z. (Univ. of Southern California School of Medicine, Los Angeles (USA))

    1990-11-01

    Episcleral plaques containing {sup 125}I sources are often used in the treatment of ocular melanoma. Within four years post-treatment, however, the majority of patients experience some visual loss due to radiation retinopathy. The high incidence of late complications suggests that careful treatment optimization may lead to improved outcome. The goal of optimization would be to reduce the magnitude of vision-limiting complications without compromising tumor control. We have developed a three-dimensional computer model for ophthalmic plaque therapy which permits us to explore the potential of various optimization strategies. One simple strategy which shows promise is to maximize the ratio of dose to the tumor apex (T) compared to dose to the macula (M). By modifying the parameters of source location, activity distribution, source orientation, and shielding we find that the calculated T:M ratio can be varied by a factor of 2 for a common plaque design and posterior tumor location. Margins and dose to the tumor volume remain essentially unchanged.

  3. Development of an automation system for iodine-125 brachytherapy seed production by (Nd:YAG) laser welding; Automacao do processo de soldagem a laser (Nd:YAG) para confeccao das sementes de iodo-125 utilizadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Somessari, Samir Luiz

    2010-07-01

    The aim of this work is to develop an automation system for iodine-125 radioactive seed production by (Nd:YAG) laser welding, which has been used successfully in Low Dose Rate (LDR) brachytherapy treatment. This small seed consists of a welded titanium capsule, with 0.8mm in diameter and 4.5mm in length, containing iodine-125 adsorbed onto a silver rod. The iodine-125 seeds are implanted into the human prostate to irradiate the tumor for cancer treatment. Nowadays, the Radiation Technology Center, at IPEN-CNEN/SP imports and distributes 36,000 iodine-125 seeds per year, for the clinics and hospitals in the country. However, the Brazilian market potential is now over 8,000 iodine-125 seeds per month. The local production of these iodine-125 radioactive sources becomes a priority for the Institute, in order to reduce the price and the problems of prostate cancer management. It will permit to spread their use to a largest number of patients in Brazil. On the other hand, the industrial automation plays an important role for iodine-125 seeds in order to increase the productivity, with high quality and assurance, avoiding human factors, implementing and operating with Good Manufacturing Practices (GMP). The technology consists of appliance electronic and electro-mechanical parts and components to control machines and processes. The automation system technology for iodine-125 seed production developed in this work was mainly assembled employing Programmable Logic Controller (PLC), stepper motors, drivers, (Nd:YAG) laser welding machine, photoelectric sensors and supervisory. (author)

  4. Post-operative treatment of malignant salivary gland tumours of the palate with iodine-125 brachytherapy

    International Nuclear Information System (INIS)

    Stannard, Clare E.; Hering, Egbert; Hough, Jan; Knowles, Ruth; Munro, Roger; Hille, Jos

    2004-01-01

    Background and purpose: Malignant minor salivary gland tumours are usually small and clinically indistinguishable from benign lesions. Surgery is the treatment of choice with post-operative radiotherapy for involved margins or unfavourable histology. We assessed the results of a series of such patients treated with iodine-125 brachytherapy in the form of a temporary applicator or implant. Patients and methods: There were nine patients with T1/T2 tumours of the hard and/or soft palate that had been excised. All had close or involved margins. Six were treated with a dental applicator alone, two with an applicator and additional I-125 seeds in tubes and one with an implant alone. The applicator consists of two layers of plastic made from a dental impression enclosing a predetermined number of I-125 seeds, 9-39, glued to one surface and a layer of ash metal to protect the tongue. It was inserted 1-3 months post-operatively and delivered 35-62 Gy, median 56 Gy, at 5-7 mm depth over 58-156 h, median 120 h, at 0.26-0.67 Gy/h, median 0.45 Gy/h. Results: The patients have been followed up for 32-158 months, median 50 months, and there were no recurrences. The applicator was well tolerated. A confluent mucositis developed which lasted 3-4 weeks. One patient developed a mucosal ulcer which healed spontaneously. Conclusions: Brachytherapy is an effective way of delivering post-operative radiotherapy to the hard and soft palate in patients with malignant salivary gland tumours that have been incompletely excised or have unfavourable histology. Local control is excellent, treatment time is short and morbidity is minimal

  5. Efficacy and safety of iodine-125 radioactive seeds brachytherapy for advanced non-small cell lung cancer-A meta-analysis.

    Science.gov (United States)

    Zhang, Wenchao; Li, Jiawei; Li, Ran; Zhang, Ying; Han, Mingyong; Ma, Wei

    This meta-analysis was conducted to investigate the efficacy and safety of 125 I brachytherapy for locally advanced non-small cell lung cancer (NSCLC). Trials comparing 125 I brachytherapy with chemotherapy in NSCLC were identified. Meta-analysis was performed to obtain pooled risk ratios for an overall response rate (ORR), disease control rate (DCR) and complications, and pooled hazard ratio for overall survival (OS). Fifteen studies including 1188 cases were included. The pooled result indicated that there were significant differences in ORR, DCR, and OS between 125 I brachytherapy combined with chemotherapy and chemotherapy alone, but no statistic differences in gastrointestinal symptoms, leukopenia, myelosuppression, and hemoglobin reduction. Patients treated with 125 I brachytherapy combined with chemotherapy have a higher relative risk of pneumothorax, bloody sputum, and pneumorrhagia compared with chemotherapy alone. Seeds migration only occurred in the group treated with 125 I brachytherapy. There were significant differences in ORR, DCR, and myelosuppression between 125 I brachytherapy alone and chemotherapy. 125 I brachytherapy combined with chemotherapy can significantly enhance the clinical efficacy and improve the OS of patients with advanced NSCLC without increasing the incidence of complications of chemotherapy. 125 I brachytherapy alone can significantly enhance the clinical efficacy and reduce the incidence of myelosuppression compared with chemotherapy. However, 125 I brachytherapy may cause lung injury. Large sample and higher-quality randomized controlled trials are needed to confirm the pooled results of complications. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  6. Leakage test evaluation used for qualification of iodine-125 seeds sealing

    International Nuclear Information System (INIS)

    Feher, Anselmo; Rostelato, Maria E.C.M.; Zeituni, Carlos A.; Calvo, Wilson A.P.; Somessari, Samir L.; Moura, Joao A.; Moura, Eduardo S.; Souza, Carla D.; Rela, Paulo R.

    2009-01-01

    The prostate cancer is a problem of public health in Brazil, and the second cause of cancer deaths in men, exceeded only by lung cancer. Among the possible treatments available for prostate cancer is brachytherapy, in which small seeds containing Iodine-125 radioisotope are implanted in the prostate. The seed consists of a sealed titanium tube measuring 0.8 mm external diameter and 4.5 mm in length, containing a central silver wire with adsorbed Iodine-125. The tube sealing is made with titanium at the ends, using electric arc welding or laser process. This sealing must be leakage-resistant and free of cracks, therefore avoiding the Iodine-125 to deposit in the silver wire to escape and spread into the human body. To ensure this problem does not occur, rigorous leakage tests, in accordance with the standard Radiation protection - Sealed Radioactive Sources - leakage Test Methods - ISO 9978, should be applied. The aim of this study is to determine, implement and evaluate the leakage test to be used in the Iodine-125 seeds production, in order to qualify the sealing procedure. The standard ISO 9978 presents a list of tests to be carried out according to the type of source. The preferential methods for brachytherapy sources are soaking and helium. To assess the seeds leakage, the method of immersion test at room temperature was applied. The seeds are considered leakage-free if the detected activity does not exceed the 185 Bq (5 nCi). An Iodine standard was prepared and its value determined in a sodium iodide detector. A liquid scintillation counter was calibrated with the standard for seeds leakage tests. Forty-eight seeds were welded for these tests. (author)

  7. SU-F-T-48: Clinical Implementation of Brachytherapy Planning System for COMS Eye Plaques

    International Nuclear Information System (INIS)

    Ferreira, C; Islam, M; Ahmad, S; De La Fuente Herman, T

    2016-01-01

    Purpose: To commission the Brachytherapy Planning (BP) system (Varian, Palo Alto, CA) for the Collaborative Ocular Melanoma Study (COMS) eye plaques by evaluating dose differences against original plans from Nucletron Planning System (NPS). Methods: NPS system is the primary planning software for COMS-plaques at our facility; however, Brachytherapy Planning 11.0.47 (Varian Medical Systems) is used for secondary check and for seed placement configurations not originally commissioned. Dose comparisons of BP and NPS plans were performed for prescription of 8500 cGy at 5 mm depth and doses to normal structures: opposite retina, inner sclera, macula, optic disk and lens. Plans were calculated for Iodine-125 seeds (OncoSeeds, Model 6711) using COMS-plaques of 10, 12, 14, 16, 18 and 20 mm diameters. An in-house program based on inverse-square was utilized to calculate point doses for comparison as well. Results: The highest dose difference between BP and NPS was 3.7% for the prescription point for all plaques. Doses for BP were higher than doses reported by NPS for all points. The largest percent differences for apex, opposite retina, inner sclera, macula, optic disk, and lens were 3.2%, 0.9%, 13.5%, 20.5%, 15.7% and 2.2%, respectively. The dose calculated by the in-house program was 1.3% higher at the prescription point, and were as high as 42.1%, for points away from the plaque (i.e. opposite retina) when compared to NPS. Conclusion: Doses to the tumor, lens, retina, and optic nerve are paramount for a successful treatment and vision preservation. Both systems are based on TG-43 calculations and assume water medium tissue homogeneity (ρe=1, water medium). Variations seen may result from the different task group versions and/or mathematical algorithms of the software. BP was commissioned to serve as a backup system and it also enables dose calculation in cases where seeds don’t follow conventional placement configuration.

  8. SU-F-T-48: Clinical Implementation of Brachytherapy Planning System for COMS Eye Plaques

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, C; Islam, M; Ahmad, S; De La Fuente Herman, T [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2016-06-15

    Purpose: To commission the Brachytherapy Planning (BP) system (Varian, Palo Alto, CA) for the Collaborative Ocular Melanoma Study (COMS) eye plaques by evaluating dose differences against original plans from Nucletron Planning System (NPS). Methods: NPS system is the primary planning software for COMS-plaques at our facility; however, Brachytherapy Planning 11.0.47 (Varian Medical Systems) is used for secondary check and for seed placement configurations not originally commissioned. Dose comparisons of BP and NPS plans were performed for prescription of 8500 cGy at 5 mm depth and doses to normal structures: opposite retina, inner sclera, macula, optic disk and lens. Plans were calculated for Iodine-125 seeds (OncoSeeds, Model 6711) using COMS-plaques of 10, 12, 14, 16, 18 and 20 mm diameters. An in-house program based on inverse-square was utilized to calculate point doses for comparison as well. Results: The highest dose difference between BP and NPS was 3.7% for the prescription point for all plaques. Doses for BP were higher than doses reported by NPS for all points. The largest percent differences for apex, opposite retina, inner sclera, macula, optic disk, and lens were 3.2%, 0.9%, 13.5%, 20.5%, 15.7% and 2.2%, respectively. The dose calculated by the in-house program was 1.3% higher at the prescription point, and were as high as 42.1%, for points away from the plaque (i.e. opposite retina) when compared to NPS. Conclusion: Doses to the tumor, lens, retina, and optic nerve are paramount for a successful treatment and vision preservation. Both systems are based on TG-43 calculations and assume water medium tissue homogeneity (ρe=1, water medium). Variations seen may result from the different task group versions and/or mathematical algorithms of the software. BP was commissioned to serve as a backup system and it also enables dose calculation in cases where seeds don’t follow conventional placement configuration.

  9. Plaque Brachytherapy for Uveal Melanoma: A Vision Prognostication Model

    International Nuclear Information System (INIS)

    Khan, Niloufer; Khan, Mohammad K.; Bena, James; Macklis, Roger; Singh, Arun D.

    2012-01-01

    Purpose: To generate a vision prognostication model after plaque brachytherapy for uveal melanoma. Methods and Materials: All patients with primary single ciliary body or choroidal melanoma treated with iodine-125 or ruthenium-106 plaque brachytherapy between January 1, 2005, and June 30, 2010, were included. The primary endpoint was loss of visual acuity. Only patients with initial visual acuity better than or equal to 20/50 were used to evaluate visual acuity worse than 20/50 at the end of the study, and only patients with initial visual acuity better than or equal to 20/200 were used to evaluate visual acuity worse than 20/200 at the end of the study. Factors analyzed were sex, age, cataracts, diabetes, tumor size (basal dimension and apical height), tumor location, and radiation dose to the tumor apex, fovea, and optic disc. Univariate and multivariable Cox proportional hazards were used to determine the influence of baseline patient factors on vision loss. Kaplan-Meier curves (log rank analysis) were used to estimate freedom from vision loss. Results: Of 189 patients, 92% (174) were alive as of February 1, 2011. At presentation, visual acuity was better than or equal to 20/50 and better than or equal to 20/200 in 108 and 173 patients, respectively. Of these patients, 44.4% (48) had post-treatment visual acuity of worse than 20/50 and 25.4% (44) had post-treatment visual acuity worse than 20/200. By multivariable analysis, increased age (hazard ratio [HR] of 1.01 [1.00-1.03], P=.05), increase in tumor height (HR of 1.35 [1.22-1.48], P<.001), and a greater total dose to the fovea (HR of 1.01 [1.00-1.01], P<.001) were predictive of vision loss. This information was used to develop a nomogram predictive of vision loss. Conclusions: By providing a means to predict vision loss at 3 years after treatment, our vision prognostication model can be an important tool for patient selection and treatment counseling.

  10. Plaque Brachytherapy for Uveal Melanoma: A Vision Prognostication Model

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Niloufer [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic, Cleveland, Ohio (United States); Khan, Mohammad K. [Department of Radiation Oncology, Emory University School of Medicine, Atlanta, Georgia (United States); Bena, James [Department of Quantitative Health Sciences, Cleveland Clinic, Cleveland, Ohio (United States); Macklis, Roger [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic, Cleveland, Ohio (United States); Singh, Arun D., E-mail: singha@ccf.org [Department of Ophthalmic Oncology, Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio (United States)

    2012-11-01

    Purpose: To generate a vision prognostication model after plaque brachytherapy for uveal melanoma. Methods and Materials: All patients with primary single ciliary body or choroidal melanoma treated with iodine-125 or ruthenium-106 plaque brachytherapy between January 1, 2005, and June 30, 2010, were included. The primary endpoint was loss of visual acuity. Only patients with initial visual acuity better than or equal to 20/50 were used to evaluate visual acuity worse than 20/50 at the end of the study, and only patients with initial visual acuity better than or equal to 20/200 were used to evaluate visual acuity worse than 20/200 at the end of the study. Factors analyzed were sex, age, cataracts, diabetes, tumor size (basal dimension and apical height), tumor location, and radiation dose to the tumor apex, fovea, and optic disc. Univariate and multivariable Cox proportional hazards were used to determine the influence of baseline patient factors on vision loss. Kaplan-Meier curves (log rank analysis) were used to estimate freedom from vision loss. Results: Of 189 patients, 92% (174) were alive as of February 1, 2011. At presentation, visual acuity was better than or equal to 20/50 and better than or equal to 20/200 in 108 and 173 patients, respectively. Of these patients, 44.4% (48) had post-treatment visual acuity of worse than 20/50 and 25.4% (44) had post-treatment visual acuity worse than 20/200. By multivariable analysis, increased age (hazard ratio [HR] of 1.01 [1.00-1.03], P=.05), increase in tumor height (HR of 1.35 [1.22-1.48], P<.001), and a greater total dose to the fovea (HR of 1.01 [1.00-1.01], P<.001) were predictive of vision loss. This information was used to develop a nomogram predictive of vision loss. Conclusions: By providing a means to predict vision loss at 3 years after treatment, our vision prognostication model can be an important tool for patient selection and treatment counseling.

  11. Iodine-125 radiation of posterior uveal melanoma

    International Nuclear Information System (INIS)

    Packer, S.

    1987-01-01

    Twenty-eight cases of posterior choroidal melanoma were treated with iodine-125 in gold eye plaques. Eleven cases were located within 3.0 mm of the optic nerve (group A), nine were within 3.0 mm of the fovea (group B), and eight were within 3.0 mm of the optic nerve and fovea (group C). The mean follow-up of group A was 46.3 months; group B, 25.5 months; and group C, 42.7 months. Complications included macular edema, cataract and tumor growth. Visual acuity remained within two lines of that tested preoperatively for 4 of 11 patients in group A, 4 of 9 in group B, and 5 of 8 in group C. These results with iodine-125 suggest it as an appropriate treatment for patients with choroidal melanoma located near optic nerve and/or macula

  12. Iodine-125 radiation of posterior uveal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Packer, S.

    1987-12-01

    Twenty-eight cases of posterior choroidal melanoma were treated with iodine-125 in gold eye plaques. Eleven cases were located within 3.0 mm of the optic nerve (group A), nine were within 3.0 mm of the fovea (group B), and eight were within 3.0 mm of the optic nerve and fovea (group C). The mean follow-up of group A was 46.3 months; group B, 25.5 months; and group C, 42.7 months. Complications included macular edema, cataract and tumor growth. Visual acuity remained within two lines of that tested preoperatively for 4 of 11 patients in group A, 4 of 9 in group B, and 5 of 8 in group C. These results with iodine-125 suggest it as an appropriate treatment for patients with choroidal melanoma located near optic nerve and/or macula.

  13. American brachytherapy society recommends no change for prostate permanent implant dose prescriptions using iodine-125 or palladium-103

    International Nuclear Information System (INIS)

    Rivard, M.J.; Butler, W.M.; Merrick, G.S.; Devlin, P.M.; Hayes, J.K.; Hearn, R.A.; Lief, E.P.; Meigooni, A.S.; Williamson, J.F.

    2008-01-01

    Purpose - In 2004, the American Association of Physicists in Medicine (AAPM) issued a report outlining recommended 125 I and 103 Pd datasets for consistency in calculating brachytherapy dose distributions. In 2005, to aid evaluating the clinical impact of implementing these datasets, the AAPM assessed the historical dependence of how prescribed doses differed from administered doses for 125 I and 103 Pd for permanent implantation of the prostate. Consequently, the American Brachytherapy Society (ABS) considered the nature of these changes towards issuing recommended dose prescriptions for 125 I and 103 Pd interstitial brachytherapy implants for mono-therapy and standard boosts. Methods and materials - An investigation was performed of the 2005 AAPM analysis to determine changes in administered dose while affixing prescribed dose using 2004 AAPM 125 I and 103 Pd brachytherapy dosimetry datasets for prostate implants. For 125 I and 103 Pd, administered dose would change by +1.4% and +4.2%, respectively. The biological and societal impact of changing prescribed dose was considered. Results - Based on the need for clinical constancy and in recognition of overall uncertainties, the ABS recommends immediate implementation of the 2004 AAPM consensus brachytherapy dosimetry datasets and no changes to 125 I and 103 Pd dose prescriptions at this time. Conclusions - Radiation oncologists should continue to prescribe mono-therapy doses of 145 Gy and 125 Gy for 125 I and 105 Pd, respectively, and standard boost doses of 100-110 Gy and 90-100 Gy for 125 I and 103 Pd, respectively. (authors)

  14. Methodology study for fixation of radioactive iodine in polymeric substrate for brachytherapy sources

    International Nuclear Information System (INIS)

    Rodrigues, Bruna T.; Rostelato, Maria Elisa C.M.; Souza, Carla D.; Tiezzi, Rodrigo; Souza, Daiane B. de; Benega, Marcos A.G.; Souza, Anderson S. de; Peleias Junior, Fernando S.; Zeituni, Calos A.; Fernandes, Vagner; Melo, Emerson Ronaldo de; Camargo, Anderson Rogerio de

    2015-01-01

    Cancer is now the second leading cause of death by disease in several countries, including Brazil. Prostate cancer is the most common among men. Brachytherapy is a modality of radiotherapy in which radioactive seeds are placed inside or in contact with the organ to be treated. The most widely used radioisotope in prostate brachytherapy is Iodine-125 which is presented fixated on a silver substrate that is subsequently placed inside a titanium capsule. A large dose of radiation is released only in the targeted tumor protecting healthy surrounding tissues. The technique requires the application of 80 - 120 seeds per patient. The implants of seeds have low impact and non-surgical procedures. Most patients can return to normal life within three days with little or no pain. This work proposes an alternative to the seeds that have already been developed, in order to reduce the cost by obtaining a better efficiency on fixing the radioactive iodine onto the epoxy resin. Methods have been developed to perform the fixation of Iodine-125 onto polymeric substrates. The parameters analyzed were the immersion time, type of static or dynamic reaction, concentration of the adsorption solution, the specific activity of the radioactive source, the need for carrier and chemical form of the radioactive Iodine. These experiments defined the most effective method to fixate the Iodine onto the polymeric material (epoxy resin), the Iodine activity in the polymeric substrate, the activity of the distribution of variation in a plot of polymeric cores and the efficiency of the epoxy resin to seal the seed. (author)

  15. A Phase III Randomized Trial of the Timing of Meloxicam With Iodine-125 Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Crook, Juanita; Patil, Nikhilesh; Wallace, Kris; Borg, Jette; Zhou, David; Ma, Clement; Pond, Greg

    2010-01-01

    Purpose: Nonsteroidal anti-inflammatory medication is used to reduce prostate edema and urinary symptoms following prostate brachytherapy. We hypothesized that a cyclooxygenase-2 (COX-2) inhibitor regimen started 1 week prior to seed implant might diminish the inflammatory response, thus reducing edema, retention rates, and symptom severity. Methods and Materials: From March 2004 to February 2008, 316 men consented to an institutional review board-approved randomized study of a 4-week course of meloxicam, 7.5 mg orally twice per day, starting either on the day of implant or 1 week prior to implant. Brachytherapy was performed using iodine-125 seeds and was preplanned and performed under transrectal ultrasound (TRUS) and fluoroscopic guidance. Prostate volume obtained by MR imaging at 1 month was compared to baseline prostate volume obtained by TRUS planimetry and expressed as an edema factor. The trial endpoints were prostate edema at 1 month, International Prostate Symptom Score (IPSS) questionnaire results at 1 and 3 months, and any need for catheterization. Results: Results for 300 men were analyzed. Median age was 61 (range, 45-79 years), and median TRUS prostate volume was 35.7 cc (range, 18.1-69.5 cc). Median IPSS at baseline was 5 (range, 0-24) and was 15 at 1 month, 16 at 3 months, and 10 at 6 months. Catheterization was required for 7% of patients (6.2% day 0 arm vs. 7.9% day -7 arm; p = 0.65). The median edema factor at 1 month was 1.02 (range, 0.73-1.7). 1.01 day 0 arm vs. 1.05 day -7 arm. Baseline prostate volume remained the primary predictor of postimplant urinary retention. Conclusions: Starting meloxicam 1 week prior to brachytherapy compared to starting immediately after the procedure did not reduce 1-month edema, improve IPSSs at 1 or 3 months, or reduce the need for catheterization.

  16. Iodine-125 irradiation of choroidal melanoma: clinical experience from the Prince of Wales and Sydney Eye Hospitals.

    Science.gov (United States)

    Mameghan, H; Karolis, C; Fisher, R; Mameghan, J; Billson, F A; Donaldson, E J; Giblin, M E; Hunyor, A B

    1992-08-01

    We examined the records of 53 patients treated for choroidal melanoma between 1985 and 1989. The aim of this study was to assess the safety and short-term results of iodine-125 episcleral plaque therapy. There were 28 males and 25 females, aged 20 to 77 years (median 61 years), treated for single tumours with a median diameter of 9 mm (range 5 to 15 mm) and with a median thickness of 4 mm (range 2 to 10 mm). The plaques containing iodine-125 seeds were chosen according to tumour size: 10 mm (16 patients); 15 mm (36 patients); 20 mm (one patient). All patients are alive at last follow-up (median 1.3 years, range 4 months to 3.3 years). Four patients underwent enucleation for melanoma progression. Thirty patients have developed some type of complication (more than one complication occurred in the same eye in 12 patients): retinitis (19), optic neuropathy (7); cataract (4), rubeosis iridis (2). Overall, visual acuity deteriorated in 32 patients, remained stable in 12 patients and improved in 9 patients. Iodine-125 plaque therapy appears to offer patients good prospects of tumour control and preservation of useful vision.

  17. Autoradiography for iodine-125 seeds

    International Nuclear Information System (INIS)

    Alberti, W.; Divoux, S.; Pothmann, B.; Tabor, P.; Hermann, K.P.; Harder, D.

    1993-01-01

    To study the interior design of model 6702 and 6711 iodine-125 seeds, contact autoradiographs were performed using mammography film. Improved resolution was obtained using a pin-hole camera with a hole of 0.1 mm x 0.1 mm. With these techniques, qualitative determination of the relative activity distribution within each seed was possible. The number of the activated resin spheres and the positions of the centers of these spheres can be exactly determined. A model calculation shows that variations in the arrangement of the activated spheres within a seed have a moderate influence on the dose distribution at source distances below 10 mm. Knowing the exact source configuration may be useful when comparing dose calculations with measured data for model 6702 125 I seeds which are currently employed in ophthalmic plaque and implant therapy of other tumors. 16 refs., 5 figs., 2 tabs

  18. Iodine-125 brachytherapy as upfront and salvage treatment for brain metastases. A comparative analysis

    Energy Technology Data Exchange (ETDEWEB)

    Romagna, Alexander; Schwartz, Christoph; Tonn, Joerg-Christian; Kreth, Friedrich-Wilhelm [Ludwig-Maximilians-University, Department of Neurosurgery, Munich (Germany); Egensperger, Rupert [Ludwig-Maximilians-University, Center for Neuropathology and Prion Research, Munich (Germany); Watson, Juliana; Belka, Claus; Nachbichler, Silke Birgit [Ludwig-Maximilians-University, Department of Radiation-Oncology, Munich (Germany)

    2016-11-15

    Outcome and toxicity profiles of salvage stereotactic ablative radiation strategies for recurrent pre-irradiated brain metastases are poorly defined. This study compared risk-benefit profiles of upfront and salvage iodine-125 brachytherapy (SBT) for small brain metastases. As the applied SBT treatment algorithm required histologic proof of metastatic brain disease in all patients, we additionally aimed to elucidate the value of biopsy before SBT. Patients with small untreated (n = 20) or pre-irradiated (n =28) suspected metastases intended for upfront or salvage SBT, respectively, were consecutively included. Temporary iodine-125 implants were used (median reference dose: 50 Gy, median dose rate: 15 cGy/h). Cumulative biologically effective doses (BED) were calculated and used for risk assessment. Treatment toxicity was classified according to Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer (RTOG/EORTC) criteria. Upfront SBT was initiated in 20 patients and salvage SBT in 23. In 5 patients, salvage SBT was withheld because of proven radiation-induced lesions. Treatment groups exhibited similar epidemiologic data except for tumor size (which was slightly smaller in the salvage group). One-year local/distant tumor control rates after upfront and salvage SBT were similar (94 %/65 % vs. 87 %/57 %, p = 0.45, respectively). Grade I/II toxicity was suffered by 2 patients after salvage SBT (cumulative BED: 192.1 Gy{sub 3} and 249.6 Gy{sub 3}). No toxicity-related risk factors were identified. SBT combines diagnostic yield with effective treatment in selected patients. The low toxicity rate in the salvage group points to protective radiobiologic characteristics of continuous low-dose rate irradiation. Upfront and salvage SBT are similarly effective and safe. Histologic reevaluation should be reconsidered after previous radiotherapy to avoid under- or overtreatment. (orig.) [German] Daten zu Risiko und Effizienz ablativer

  19. Quality Assurance Procedure Development in Iodine-125 Seeds Production

    International Nuclear Information System (INIS)

    Moura, J.A.; Moura, E.S.; Sprenger, F.E.

    2009-01-01

    Brachytherapy using Iodine-125 seeds has been used in prostate cancer treatment. In the quality control routine during seed production, leak tests are made to detect any leakage of radioactive material from inside the titanium shield. Leak tests are made according to the International Standard Organization- Radiation protection - sealed radioactive sources - ISO 9978 standard, and require liquid transfer between recipients. If any leakage happens, there will be contamination of the liquid and tubing. This study aims to establish decontamination routines for tubing, allowing its repeated use, in the automated assay process

  20. Long-Term Results of Brachytherapy With Temporary Iodine-125 Seeds in Children With Low-Grade Gliomas

    International Nuclear Information System (INIS)

    Korinthenberg, Rudolf; Neuburger, Daniela; Trippel, Michael; Ostertag, Christoph; Nikkhah, Guido

    2011-01-01

    Purpose: To retrospectively review the results of temporary I-125 brachytherapy in 94 children and adolescents with low-grade glioma. Methods and Materials: Treatment was performed in progressive tumors roughly spherical in shape with a diameter of up to 5 cm, including 79 astrocytomas, 5 oligodendrogliomas, 4 oligoastrocytomas, 1 ependymoma, and 5 other tumors. Location was suprasellar/chiasmal in 44, thalamic/basal ganglia in 18, hemispheric in 15, midbrain/pineal region in 13, and lower brainstem in 3. Initially, 8% of patients were free of symptoms, 47% were symptomatic but not disabled, and 30% were slightly, 6% moderately, and 3% severely disabled. Results: 5- and 10-year survival was 97% and 92%. The response to I-125 brachytherapy over the long term was estimated after a median observation period of 38.4 (range, 6.4-171.0) months. At that time, 4 patients were in complete, 27 in partial, and 18 in objective remission; 15 showed stable and 30 progressive tumors. Treatment results did not correlate with age, sex, histology, tumor size, location, or demarcation of the tumor. Secondary treatment became necessary in 36 patients, including 19 who underwent repeated I-125 brachytherapy. At final follow-up, the number of symptom-free patients had risen to 21%. Thirty-eight percent showed symptoms without functional impairment, 19% were slightly and 11% moderately disabled, and only 4% were severely disabled. Conclusions: Response rates similar to those of conventional radiotherapy or chemotherapy can be anticipated with I-125 brachytherapy in tumors of the appropriate size and shape. We believe it to be a useful contribution to the treatment of low-grade gliomas in children.

  1. Iodine-125 irradiation of choroidal melanoma: clinical experience from the Prince of Wales and Sydney Eye Hospitals

    International Nuclear Information System (INIS)

    Mameghan, H.; Karolis, Ch.; Fisher, R.; Mameghan, J.; Billson, F.A.; Donaldson, E.J.; Giblin, M.E.; Hunyor, A.B.L.

    1992-01-01

    The records of 53 patients treated for choroidal melanoma between 1985 and 1989 were examined. The aim of this study was to assess the safety and short-term results of iodine-125 episcleral plaque therapy. There were 28 males and 25 females aged 20 to 77 years, treated for single tumours with a median diameter of 9 mm (range 5 to 16 mm) and with a median thickness of 4 mm (range 2 to 10 mm). The plaques containing iodine-125 seeds were chosen according to tumour size: 10 mm (16 patients); 15 mm (36 patients); 20 mm (one patient). All patients were alive at last follow-up (median 1.3 years, range 4 months to 3.3 years). Four patients underwent enucleation for melanoma progression. Thirty patients have developed some type of complication (more than one complication occurred in the same eye in 12 patients); retinitis (19), optic neuropathy (7); cataract (4), rubeosis iridis (2). Overall, visual acuity deteriorated in 32 patients, remained stable in 12 patients and improved in 9 patients. It was therefore concluded that iodine-125 plaque therapy appears to offer patients good prospects of tumour control and preservation of useful vision. 16 refs., 4 tabs

  2. Radiobiology for eye plaque brachytherapy and evaluation of implant duration and radionuclide choice using an objective function

    International Nuclear Information System (INIS)

    Gagne, Nolan L.; Leonard, Kara L.; Rivard, Mark J.

    2012-01-01

    Purpose: Clinical optimization of Collaborative Ocular Melanoma Study (COMS) eye plaque brachytherapy is currently limited to tumor coverage, consensus prescription dosage, and dose calculations to ocular structures. The biologically effective dose (BED) of temporary brachytherapy treatments is a function of both chosen radionuclide R and implant duration T. This study endeavored to evaluate BED delivered to the tumor volume and surrounding ocular structures as a function of plaque position P, prescription dose, R, and T. Methods: Plaque-heterogeneity-corrected dose distributions were generated with MCNP5 for the range of currently available COMS plaques loaded with sources using three available low-energy radionuclides. These physical dose distributions were imported into the PINNACLE 3 treatment planning system using the TG-43 hybrid technique and used to generate dose volume histograms for a T = 7 day implant within a reference eye geometry including the ciliary body, cornea, eyelid, foveola, lacrimal gland, lens, optic disc, optic nerve, retina, and tumor at eight standard treatment positions. The equation of Dale and Jones was employed to create biologically effective dose volume histograms (BEDVHs), allowing for BED volumetric analysis of all ROIs. Isobiologically effective prescription doses were calculated for T = 5 days down to 0.01 days, with BEDVHs subsequently generated for all ROIs using correspondingly reduced prescription doses. Objective functions were created to evaluate the BEDVHs as a function of R and T. These objective functions are mathematically accessible and sufficiently general to be applied to temporary or permanent brachytherapy implants for a variety of disease sites. Results: Reducing T from 7 to 0.01 days for a 10 mm plaque produced an average BED benefit of 26%, 20%, and 17% for 103 Pd, 125 I, and 131 Cs, respectively, for all P; 16 and 22 mm plaque results were more position-dependent. 103 Pd produced a 16%–35% BED benefit over

  3. [Brachytherapy of brainstem tumors].

    Science.gov (United States)

    Julow, Jenö; Viola, Arpád; Major, Tibor; Valálik, István; Sági, Sarolta; Mangel, László; Kovács, Rita Beáta; Repa, Imre; Bajzik, Gábor; Németh, György

    2004-01-20

    The optimal therapy of brain stem tumours of different histopathology determines the expected length of survival. Authors report 125Iodine interstitial irradiation of brain stem tumours with stereotactic brachytherapy. Two patients having brain stem tumours were suffering from glioma or from metastases of a carcinoma. In Case 1 the tumour volume was 1.98 cm3 at the time of planning interstitial irradiation. The control MRI examination performed at 42 months post-op showed a postirradiation cyst size of 5.73 cm3 indicating 65.5% shrinkage. In Case 2 the shrinkage was more apparent as the tumour volume measured on the control MRI at 8 months post-op was only 0.16 cm3 indicating 97.4% shrinkage of the 6.05 cm3 target volume at the time of brachytherapy with the metastasis practically disappearing. Quick access to histopathological results of the stereotactic intraoperative biopsy made it possible to carry out the 125Iodine stereotactic brachytherapy immediately after the biopsy, resulting in less inconvenience for patients of a second possible intervention. The control MRI scans show significant shrinkage of tumours in both patients. The procedure can be performed as a biopsy. The CT and image fusion guided 125Iodine stereotactic brachytherapy can be well planned dosimetrically and is surgically precise.

  4. Mock iodine-125 radiation source

    International Nuclear Information System (INIS)

    Coffey, D.L.

    1976-01-01

    An intimate mixture of americium-241 and iodine-129 provides an energy spectrum that reliably simulates the spectrum of iodine-125 in a well-type detector. As such, it may be used as a long-lived standard to calibrate instruments such as well scintillation spectrometers in which measurements are to be made involving iodine-125

  5. A robotic device for MRI-guided prostate brachytherapy

    NARCIS (Netherlands)

    Lagerburg, V.

    2008-01-01

    One of the treatment options for prostate cancer is brachytherapy with iodine-125 sources. In prostate brachytherapy a high radiation dose is delivered to the prostate with a steep dose fall off to critical surrounding organs. The implantation of the iodine sources is currently performed under

  6. Study and methodology development for quality control in the production process of iodine-125 radioactive sealed sources applied to brachytherapy

    International Nuclear Information System (INIS)

    Moura, Joao Augusto

    2009-01-01

    Today cancer is the second cause of death by disease in several countries, including Brazil. Excluding skin cancer, prostate cancer is the most incident in the population. Prostate tumor can be treated by several ways, including brachytherapy, which consists in introducing sealed radioactive sources (Iodine - 125 seeds) inside the tumor. The target region of treatment receives a high radiation dose, but healthy neighbor tissues receive a significantly reduced radiation dose. The seed is made of a welding sealed titanium capsule, 0.8 mm external diameter and 4.5 mm length, enclosing a 0.5 mm diameter silver wire with Iodine-125 adsorbed. After welded, the seeds have to be submitted to a leak test to prevent any radioactive material release. The aims of this work were: (a) the study of the different leakage test methods applied to radioactive seeds and recommended by the ISO 997820, (b) the choice of the appropriate method and (c) the flowchart determination of the process to be used during the seeds production. The essays exceeded the standards with the use of ultra-sound during immersion and the corresponding benefits to leakage detection. Best results were obtained with the immersion in distilled water at 20 degree C for 24 hours and distilled water at 70 degree C for 30 minutes. These methods will be used during seed production. The process flowchart has all the phases of the leakage tests according to the sequence determined in the experiments. (author)

  7. Embolization of an iodine-125 radioactive seed from the prostate gland into the right ventricle: An unusual pattern of seed migration

    International Nuclear Information System (INIS)

    Schild, Michael H.; Wong, William W.; Vora, Sujay A.; Ward, Lynn D.; Nguyen, Ba D.

    2009-01-01

    Transperineal permanent brachytherapy using iodine-125 or palladium-103 seeds is a standard treatment modality for localized prostate cancer. Migration of seeds to the lungs is a common phenomenon, whereas migration of seeds to the right ventricle is a rare event. We report a case of iodine-125 seed migration to the right ventricle as demonstrated by chest CT scan and add to the very few published reports on this finding. These rare patients did not suffer adverse effects from such event.

  8. Use of brachytherapy with permanent implants of iodine-125 in localized prostate cancer; La curietherapie par implants permanents d'I-125 dans le cancer localise de la prostate

    Energy Technology Data Exchange (ETDEWEB)

    Bladou, F.; Serment, G. [Hopital Salvador, Service d' Urologie, 13 - Marseille (France); Salem, N.; Simonian, M. [Hopital Salvador, Dept. de Radiotherapie, 13 - Marseille (France); Rosello, R.; Ternier, F. [Institut Paoli-Calmettes, Dept. de Radiologie, 13 - Marseille (France)

    2002-07-01

    Approximately 15,000 cases of early stage prostate cancer T1 and T2 are diagnosed every year in France by testing for PSA and performing prostatic biopsies. The treatment of these localized forms is based in most cases on radical prostatectomy or nn external beam radiotherapy. Although the ontological results obtained by these two therapeutic methods are satisfactory and equivalent in the long term, the side effects can be important. For a number of years, trans-perineal brachytherapy using permanent implants of iodine -125 or palladium-103 has proved itself as an alternative therapy with equivalent medium to long-term results. The low urinary, digestive and sexual side effects of prostate brachytherapy are important reasons for the enthusiasm among patients and the medical community for this therapy and the growing number of applications and centres which practice it. In September 1998 we started the prostate brachytherapy programmes- in Marseilles with close collaboration between the department of urology of the Hopital Salvator, and the departments of radiotherapy, medical imaging and medical physics of the Institut Paoli-Calmettes. To date, around 250 patients with localized adenocarcinoma of the prostate have benefited from this alternative therapy in our centre. Preliminary results, with a 3 year-follow-up, are comparable to results published in the literature by pioneer teams. (authors)

  9. Carcinological results at five years of the prostate brachytherapy by iodine 125 implants. About 327 cases; Resultats carcinologiques a cinq ans de la curietherapie de prostate par implants d'iode 125. A propos de 327 cas

    Energy Technology Data Exchange (ETDEWEB)

    Peiffert, D.; Bernier, V.; Aletti, P.; Noela, A.; Marchesi, V. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France); Cormier, L.; Moreau, J.L. [CHU, Service d' Urologie, 54 - Nancy (France)

    2006-11-15

    The prostate brachytherapy by iodine 125 implants is reserved to patients damaged by a favourable prognosis cancer. The objective of this study is to present the carcinological results at five years in these indications with a technique keeping urethra. The achieving of a P.S.A. nadir inferior to 0.5 ng/ml is long. the technique used in this study keeping urethra and respecting the inclusion criteria recommended allows to get results as less equivalent as these ones of big series previously published with a low failure rate. (N.C.)

  10. Comparison between methods for fixing radioactive iodine in silver substrate for manufacturing brachytherapy sources

    Energy Technology Data Exchange (ETDEWEB)

    Peleias Junior, Fernando S.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M., E-mail: fernandopeleias@gmail.com, E-mail: czeituni@ipen.br, E-mail: elisaros@ipen.br; and others

    2013-07-01

    Cancer is a term used generically to represent a group of more than 100 illnesses, including malignant tumors from different locations. According to World Health Organization (WHO), is a leading cause of death worldwide, accounted for 7.6 million deaths. Prostate cancer is the sixth most common type in the world, representing about 10% of all cases of cancer and its treatment may be by surgery, radiotherapy or even vigilant observation. A method of radiotherapy which has been extensively used in the early and intermediate stages of the illness is brachytherapy, where radioactive seeds are placed inside or next to the area requiring treatment, which reduces the probability of unnecessary damage to surrounding healthy tissues. Currently, the radioactive isotope Iodine-125, adsorbed on silver substrate, is one of the most used in prostate brachytherapy. The present study compares several deposition methods of radioactive Iodine on silver substrate, in order to choose the most suitable one to be implemented at the laboratory of radioactive sources production of IPEN. The methodology used was chosen based on the available infrastructure and experience of the researchers of the institute. Therefore, Iodine-131 was used for testing (same chemical behavior of Iodine -125). Three methods were selected: method 1 (test based on electrodeposition method, developed by David Kubiatowicz) which presented efficiency of 65.16% ; method 2 (chemical reaction based on the method developed by David Kubiatowicz -HCl) which presented efficiency of 70.80%; method 3 (chemical reaction based on the method developed by Dr. Maria Elisa Rostelato) which presented efficiency of 55.80% . Based on the results, the second method is the suggested one to be implemented at the laboratory of radioactive sources production of IPEN. (author)

  11. Comparison between methods for fixing radioactive iodine in silver substrate for manufacturing brachytherapy sources

    International Nuclear Information System (INIS)

    Peleias Junior, Fernando S.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.

    2013-01-01

    Cancer is a term used generically to represent a group of more than 100 illnesses, including malignant tumors from different locations. According to World Health Organization (WHO), is a leading cause of death worldwide, accounted for 7.6 million deaths. Prostate cancer is the sixth most common type in the world, representing about 10% of all cases of cancer and its treatment may be by surgery, radiotherapy or even vigilant observation. A method of radiotherapy which has been extensively used in the early and intermediate stages of the illness is brachytherapy, where radioactive seeds are placed inside or next to the area requiring treatment, which reduces the probability of unnecessary damage to surrounding healthy tissues. Currently, the radioactive isotope Iodine-125, adsorbed on silver substrate, is one of the most used in prostate brachytherapy. The present study compares several deposition methods of radioactive Iodine on silver substrate, in order to choose the most suitable one to be implemented at the laboratory of radioactive sources production of IPEN. The methodology used was chosen based on the available infrastructure and experience of the researchers of the institute. Therefore, Iodine-131 was used for testing (same chemical behavior of Iodine -125). Three methods were selected: method 1 (test based on electrodeposition method, developed by David Kubiatowicz) which presented efficiency of 65.16% ; method 2 (chemical reaction based on the method developed by David Kubiatowicz -HCl) which presented efficiency of 70.80%; method 3 (chemical reaction based on the method developed by Dr. Maria Elisa Rostelato) which presented efficiency of 55.80% . Based on the results, the second method is the suggested one to be implemented at the laboratory of radioactive sources production of IPEN. (author)

  12. Radiation exposure to operating room staff during prostate brachytherapy using iodine-125 seeds; Exposition radiologique de l'equipe operatoire au cours de curietherapies de prostate par implants permanents d'iode-125

    Energy Technology Data Exchange (ETDEWEB)

    Gagna, G.; Amabile, J.C.; Laroche, P. [Service de protection radiologique des armees (SPRA), 1 bis rue du Lieutenant Raoul Batany, 92141 Clamart Cedex (France); Gauron, C. [Institut national de recherche et de securite (INRS), Departement Etudes et Assistance Medicales, 30 rue Olivier Noyer, 75680 Paris Cedex 14 (France)

    2011-04-15

    The French defense radiation protection service (SPRA) and the French national institute for research and safety (INRS) conducted a joint study to assess the radiation exposure to operating room staff during prostate brachytherapy using iodine-125 seeds at the Val-de-Grace military hospital. The purpose of the study was the assessment of the effective doses, the equivalent doses to the extremities and lens received by a novice team, the different ambient dose equivalent rates measurements and the delineation of areas. After six brachy-therapies, all the recorded doses with whole-body InLight{sup R} OSL and nanoDot{sup R} dosimeters remained below the detection limit for the whole staff. The dose rate measured at the end of implantation by an AT1123{sup R} survey meter is about 170 {mu}Sv/h at the perineum of the patient. The controlled area limit is estimated to be about 20 cm from the patient perineum. From these results, the authors propose recommendations for the categorization of workers, the delineation of areas and the dose monitoring procedures. This study demonstrates that real-time ultrasound-guided trans-perineal prostate brachytherapy delivers low dose to the operators because of the radioactive source characteristics and the instrumentation providing an effective radiation protection for the surgical team. (authors)

  13. Recovery of iodine as iodine-125 from biological materials prior to assay

    International Nuclear Information System (INIS)

    Jones, G.B.; Belling, G.B.; Buckley, R.A.

    1979-01-01

    In biological tissues iodine is usually present as iodoamino acids or iodoproteins. The organic material must be oxidised and the iodine converted into iodate prior to the final spectrophotometric determination. At parts per billion (10 9 ) levels, recoveries of added iodine are difficult to measure precisely as iodine can easily be lost from the sample and added inorganic iodine may not be recovered in the same proportions as the naturally occurring iodine. Iodine-125 provides a much more sensitive, specific and accurate means of testing the recovery of nanogram amounts of iodine from biological tissues and it can be incorporated into tissues in the naturally occurring compounds. Plants can be grown in a solution culture containing iodine-125 and animals can be injected with iodine-125 to provide tissues where naturally occurring iodine compounds are labelled with radioactive iodine. These tissues can be used to examine the recovery of iodine after oven drying, freeze drying, alkali ashing and acid digestion of the samples. Experimental details are given for spinach, tobacco, oats, cauliflower and thyroid. Results are given and discussed. (author)

  14. Iodine-125 orbital brachytherapy with a prosthetic implant in situ

    Energy Technology Data Exchange (ETDEWEB)

    Stannard, Clare [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Radiation Oncology; Maree, Gert; Munro, Roger [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Medical Physics; Lecuona, Karin [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Ophthalmology; Sauerwein, Wolfgang [Universitaetsklinikum Essen (Germany). Strahlenklinik, NCTeam

    2011-05-15

    Purpose: Brachytherapy is one method of irradiating the orbit after enucleation of an eye with a malignant tumor that has a potential to recur. It consists of 6 trains of I-125 seeds placed around the periphery of the orbit, a shorter central train, and a metal disc, loaded with seeds, placed beneath the eyelids. The presence of a prosthetic orbital implant requires omission of the central train and adjustment of the activity of the seeds in the anterior orbit around the prosthesis. Patients and Methods: This is a retrospective review of the technical modifications and outcome of 12 patients treated in this manner: 6 with retinoblastoma, 5 with malignant melanoma, and 1 with an intraocular rhabdomyosarcoma. The median dose was 35.5 Gy in 73 hours for retinoblastoma and 56 Gy in 141 hours for malignant melanoma. Patients with retinoblastoma and rhabdomyosarcoma also received chemotherapy. Results: The tubes can be placed satisfactorily around the prosthesis. The increased activity in the anterior half of the tubes produced comparable dose distributions. There have been no orbital recurrences, no extrusion of the prosthesis, and cosmesis is good. Conclusion: Insertion of a prosthetic implant at the time of enucleation greatly enhances the subsequent cosmetic appearance. This should be encouraged unless there is frank tumor in the orbit. Orbital brachytherapy without the central train continues to give excellent local control. The short treatment time and good cosmesis are added advantages. The patient is spared the expense and inconvenience of removing and replacing the prosthetic implant. (orig.)

  15. Criteria for safe working with iodine-125

    International Nuclear Information System (INIS)

    Linsley, G.S.

    1977-01-01

    Radio-immunoassay and other saturation assay tests involving the use of iodine-125 are finding wide application for the determination of hormone concentrations in biological fluids. In such tests, iodinations involving concentrations of a milli-curie per micro-litre are common. Iodine-125 presents a problem from the monitoring standpoint because of its low energy photon emission (27 and 35 keV). Iodine is preferentially taken up by the thyroid gland and work involving moderate amounts of radio-iodine may give rise to a significant hazard in an accident situation. The general precautions which should be taken in work with unsealed radioactive substances are briefly summarized, working limits for iodine-125 are identified, and methods of personal protection and monitoring in an emergency situation described. (author)

  16. BEDVH--A method for evaluating biologically effective dose volume histograms: Application to eye plaque brachytherapy implants

    International Nuclear Information System (INIS)

    Gagne, Nolan L.; Leonard, Kara L.; Huber, Kathryn E.; Mignano, John E.; Duker, Jay S.; Laver, Nora V.; Rivard, Mark J.

    2012-01-01

    Purpose: A method is introduced to examine the influence of implant duration T, radionuclide, and radiobiological parameters on the biologically effective dose (BED) throughout the entire volume of regions of interest for episcleral brachytherapy using available radionuclides. This method is employed to evaluate a particular eye plaque brachytherapy implant in a radiobiological context. Methods: A reference eye geometry and 16 mm COMS eye plaque loaded with 103 Pd, 125 I, or 131 Cs sources were examined with dose distributions accounting for plaque heterogeneities. For a standardized 7 day implant, doses to 90% of the tumor volume ( TUMOR D 90 ) and 10% of the organ at risk volumes ( OAR D 10 ) were calculated. The BED equation from Dale and Jones and published α/β and μ parameters were incorporated with dose volume histograms (DVHs) for various T values such as T = 7 days (i.e., TUMOR 7 BED 10 and OAR 7 BED 10 ). By calculating BED throughout the volumes, biologically effective dose volume histograms (BEDVHs) were developed for tumor and OARs. Influence of T, radionuclide choice, and radiobiological parameters on TUMOR BEDVH and OAR BEDVH were examined. The nominal dose was scaled for shorter implants to achieve biological equivalence. Results: TUMOR D 90 values were 102, 112, and 110 Gy for 103 Pd, 125 I, and 131 Cs, respectively. Corresponding TUMOR 7 BED 10 values were 124, 140, and 138 Gy, respectively. As T decreased from 7 to 0.01 days, the isobiologically effective prescription dose decreased by a factor of three. As expected, TUMOR 7 BEDVH did not significantly change as a function of radionuclide half-life but varied by 10% due to radionuclide dose distribution. Variations in reported radiobiological parameters caused TUMOR 7 BED 10 to deviate by up to 46%. Over the range of OAR α/β values, OAR 7 BED 10 varied by up to 41%, 3.1%, and 1.4% for the lens, optic nerve, and lacrimal gland, respectively. Conclusions: BEDVH permits evaluation of the

  17. Analysis of the necessary radioprotection procedures in manufacture and transport of iodine-125 sources used in brachytherapy;Analise dos procedimentos de radioprotecao necessarios na manufatura e no transporte de fontes de iodo-125 usadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Souza, C.D.; Hilario, K.F.; Rostelato, M.E.C.M. [Instituto de Pesquisas Energeticas e Nucleares (CTR/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes

    2009-07-01

    The estimates for the year 2009 show that 466,730 new cancer cases will occur in Brazil. Prostate cancer is the second most incident type. Brachytherapy, a type of radiotherapy, with Iodine-125 sources are an important form of treatment for this kind of cancer. The Energy and Nuclear Research Institute IPEN-CNEN/SP created a project to develop a national prototype of these sources and is implementing a facility for local production. The seeds manufacture in Brazil will allow to diminish the treatment cost and make it possible for a larger number of patients. This study aim to evaluate the procedures for transport and radiation protection requirements for employees with imported sources in order to tailor them for use in the new laboratory. Before being sent to hospitals, the packages are monitored by a radioprotection supervisor. Despite Iodine-125 presents low-energy photons, about 29 keV, local and personal dosimeters are used during transport, as described in the standards. The results showed no significant contamination or occupational exposure, validating the existing method. The transport procedure is correct, according to the regulations. For local production, new detectors should be implemented. (author)

  18. Iodine-125 seed brachytherapy for early stage prostate cancer: a single-institution review

    International Nuclear Information System (INIS)

    Zuber, Simon; Weiß, Susan; Baaske, Dieter; Schöpe, Michael; Stevens, Simon; Bodis, Stephan; Zwahlen, Daniel R

    2015-01-01

    We are reporting the five-year biochemical control, toxicity profile and dosimetric parameters using iodine-125 low dose rate brachytherapy (BT) as monotherapy for early stage prostate cancer at a single institution. Between April 2006 and December 2010, 169 men with early stage prostate cancer were treated with BT. Biochemical failure was defined using the Phoenix definition (nadir + 2 ng/mL). Treatment-related morbidities, including urinary, rectal and sexual function, were measured, applying the International Prostate Symptom Score (IPSS), the 7-grade Quality of Life Scale (QoL) and medical status, the International Consultation on Incontinence Modular Questionnaire (ICIQ), the International Index of Erectile Function (IIEF-5) and the Common Terminology Criteria for Adverse Events (CTCAE v4.03). Seed migration and loss, dosimetric parameters and learning effects were also analyzed. Medium follow-up time was 50 months (range, 1–85 months). The five-year biochemical failure rate was 7%. Acute proctitis rates were 19% (grade 1) and 1% (grade 2), respectively. The overall incidence of incontinence was 19% (mild), 16% (moderate) and < 1% (severe). An increase in IPSS ≥ 5 points was detected in 59% of patients, with 38% regaining their baseline. Seed dislocation was found in 24% of patients and correlated with D90 and V100. A learning curve was found for seed migration, D90 and V100. QoL correlated with the general health condition of patient, incontinence symptoms and IPSS. BT for early stage prostate cancer offers excellent five-year biochemical control with low toxicities. QoL aspects are favorable. A learning curve was detected for procedural aspects but its impact on patient relevant endpoints remains inconclusive

  19. Phase I Trial of Gross Total Resection, Permanent Iodine-125 Brachytherapy, and Hyperfractionated Radiotherapy for Newly Diagnosed Glioblastoma Multiforme

    International Nuclear Information System (INIS)

    Chen, Allen M.; Chang, Susan; Pouliot, Jean; Sneed, Penny K.; Prados, Michael D.; Lamborn, Kathleen R.; Malec, Mary K.; McDermott, Michael W.; Berger, Mitchell S.; Larson, David A.

    2007-01-01

    Purpose: To evaluate the feasibility of gross total resection and permanent I-125 brachytherapy followed by hyperfractionated radiotherapy for patients with newly diagnosed glioblastoma. Methods and Materials: From April 1999 to May 2002, 21 patients with glioblastoma multiforme were enrolled on a Phase I protocol investigating planned gross total resection and immediate placement of permanent I-125 seeds, followed by postoperative hyperfractionated radiotherapy to a dose of 60 Gy at 100 cGy b.i.d., 5 days per week. Median age and Karnofsky performance status were 50 years (range, 32-65 years) and 90 (range, 70-100), respectively. Toxicity was assessed according to Radiation Therapy Oncology Group criteria. Results: Eighteen patients completed treatment according to protocol. The median preoperative tumor volume on magnetic resonance imaging was 18.6 cm 3 (range, 4.4-41.2 cm 3 ). The median brachytherapy dose measured 5 mm radially outward from the resection cavity was 400 Gy (range, 200-600 Gy). Ten patients underwent 12 reoperations, with 11 of 12 reoperations demonstrating necrosis without evidence of tumor. Because of high toxicity, the study was terminated early. Median progression-free survival and overall survival were 57 and 114 weeks, respectively, but not significantly improved compared with historical patients treated at University of California, San Francisco, with gross total resection and radiotherapy without brachytherapy. Conclusions: Treatment with gross total resection and permanent I-125 brachytherapy followed by hyperfractionated radiotherapy as performed in this study results in high toxicity and reoperation rates, without demonstrated improvement in survival

  20. Thyroid measurements of Iodine-125 workers

    International Nuclear Information System (INIS)

    Burns, P.A.; Peggie, J.R.

    1979-02-01

    The accumulation of 125 I in the thyroid presents real hazards to workers who use this radionuclide. Recent assessments of the maximum permissible thyroid burden for 125 I have tended to be lower than those previously adopted. Workers using 125 I may receive small doses to a film badge monitor from external radiation while accumulating significant doses to the thyroid from internal contamination. It is therefore necessary to perform some form of thyroid monitoring on such workers. In the past two years the Australian Radiation Laboratory has monitored 125 I workers from six different institutations in the Melbourne area to determine the activity of 125 I in their thyroids. Most of the levels monitored were less than one tenth of the most recently recommended thyroid burden of 400 nanocurie. The highest levels were measured in workers who actually perform iodinations. Workers who handle the iodinate generally had lower levels than those performing the iodinations. Only a very small number of the workers measured were below the detectable limit of the system indicating that even when low activities of 125 I are handled in relatively stable forms it is still possible to accumulate 125 I in the thyroid

  1. Relationship between two year PSA nadir and biochemical recurrence in prostate cancer patients treated with iodine-125 brachytherapy; A relacao entre PSA nadir de dois anos e recidiva bioquimica no tratamento do cancer de prostata com braquiterapia de semente de iodo-125

    Energy Technology Data Exchange (ETDEWEB)

    Franca, Carlos Antonio da Silva; Vieira, Sergio Lannes; Penna, Antonio Belmiro Rodrigues Campbell, E-mail: carlosfranca@cremerj.org.br [Instituto Brasileiro de Oncologia (IBO), Rio de Janeiro, RJ (Brazil); Radioterapia Botafogo, Rio de janeiro, RJ (Brazil); Carvalho, Antonio Carlos Pires [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Bernabe, Antonio Jose Serrano [Radioterapia Botafogo, Rio de janeiro, RJ (Brazil)

    2014-03-15

    Objective: to evaluate the relationship between two year PSA nadir (PSAn) after brachytherapy and biochemical recurrence rates in prostate cancer patients. Materials and methods: In the period from January 1998 to August 2007, 120 patients were treated with iodine-125 brachytherapy alone. The results analysis was based on the definition of biochemical recurrence according to the Phoenix Consensus. Results: biochemical control was observed in 86 patients (71.7%), and biochemical recurrence, in 34 (28.3%). Mean PSAn was 0.53 ng/ml. The mean follow-up was 98 months. The patients were divided into two groups: group 1, with two year PSAn < 0.5 ng/ml after brachytherapy (74 patients; 61.7%), and group 2, with two year PSAn ≥ 0.5 ng/ml after brachytherapy (46 patients; 38.3%). Group 1 presented biochemical recurrence in 15 patients (20.3%), and group 2, in 19 patients (43.2%) (p < 0.02). The analysis of biochemical disease-free survival at seven years, stratified by the two groups, showed values of 80% and 64% (p < 0.02), respectively. Conclusion: levels of two year PSAn ≥ 0.5 ng/ml after brachytherapy are strongly correlated with a poor prognosis. This fact may help to identify patients at risk for disease recurrence. (author)

  2. Film dosimetry analyses on the effect of gold shielding for Iodine-125 eye plaque therapy for choroidal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Wu, A. (Department of Radiation Oncology, University of Pittsburgh, School of Medicine, Joint Radiation Oncology Center and Pittsburgh Cancer Institute, Pittsburgh, PA (USA)); Krasin, F. (Department of Radiation Oncology, Tufts University School of Medicine, New England Medical Center, Boston, MA (USA))

    1990-09-01

    One of the methods currently being used to treat choroidal melanoma employs an episcleral plaque containing I-125 radioactive seeds. However, comprehensive dosimetry studies on the plaque are scarce and controversial. For this work, we use film to study the dosimetry outside the lip of the gold shield of the eye plaque. This lip around the gold shield was made to protect the critical structures behind and adjacent to the lesion. Since the changes of energy spectrum of I-125 in tissue are negligible, film dosimetry seems to be a logical choice because of high spatial resolution required around the lip of the gold plaque. For this study, we first established an H and D curve with dose expressed in a unit of specific dose rate constant. This avoids absolute dose measurements. All film density measurements are made with a 1-mm aperture scan, normalized to the density at the prescription point for tumor of 3--5-mm apical height, i.e., 5 mm from the interior surface of sclera, and converted to percentage isodose curves. With a gold shield, it is found that when the plaque is placed against the optical nerve, the optical disk and macula, located at 2 mm outside the lip, on the exterior surface of sclera, may receive 85% of the prescription dose for a 12-mm plaque and 58% for a 16-mm plaque. For tumors of 8-mm apical height, the optical nerve would receive more than the prescription dose.

  3. Local radiolytic effectiveness of Auger electrons of iodine-125 in benzene-iodine solutions

    International Nuclear Information System (INIS)

    Uenak, P.; Uenak, T.

    1987-01-01

    High radiotoxicity of iodine-125 has been mainly attributed to the local radiolytic effects of Auger electrons on biological systems. In the present study, experimental and theoretical results are compared. The agreement between the experimental and theoretical results explains that the energy absorption of iodine aggregates has an important role in the radiolytic effectiveness of Auger electrons and iodine-125 in benzene-iodine solutions. (author) 18 refs.; 3 figs

  4. Comparison between methods for fixing radioactive iodine in silver substrate for manufacturing brachytherapy sources

    International Nuclear Information System (INIS)

    Souza, Carla Daruich

    2012-01-01

    Among the different ways to treat prostate cancer, brachytherapy with iodine- 125 seeds is an option that provides good results and fewer side effects. In the present study several deposition methods of radioactive iodine in a silver substrate were compared in order to choose the most suitable alternative for the routine production to be implemented at IPEN's laboratory. The methodology used was chosen based on the available infrastructure and experience of the researchers present. Therefore, the 131 I was used for testing (same chemical behavior as 131 I). Four methods were selected: Method 1 (test based on electrodeposition method developed by D.Kubiatowicz) presented 65.16% efficiency; Method 2 (chemical reaction based on the method developed by D. Kubiatowicz - HCl) with the result of 70.80% efficiency; method 3 (chemical reaction based on the method developed by Dr. Maria Elisa Rostelato) with 55.80% efficiency; Method 4 (IQ-IPEN) resulted in 99% efficiency. Since this method has more radioactive material fixation (which represents virtually the entire cost of the seed), the final price is the cheapest. This method is the suggested one to be implemented in the IPEN's laboratory for brachytherapy sources production. Besides, the method is the fasted one. (author)

  5. Three-dimensional dosimetry imaging of I-125 plaque for eye cancer treatment

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, M.; Green, J.; Petasecca, M.; Lerch, M.L.F.; Cutajar, D.; Franklin, D. [Centre for Medical Radiation Physics-University of Wollongong, Northfileds Avenue, Wollongong 2500 NSW (Australia); Jakubek, J. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, 12800 Prague 2 (Czech Republic); Carolan, M.G. [Centre for Medical Radiation Physics-University of Wollongong, Northfileds Avenue, Wollongong 2500 NSW (Australia); Illawarra Cancer Care Centre, Wollongong 2500 NSW (Australia); Conway, M. [Sydney Eye Hospital-Faculty of Medicine, The University of Sydney, Sydney 2006 NSW (Australia); Pospisil, S. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, 12800 Prague 2 (Czech Republic); Kron, T. [Peter MacCallum Cancer Centre, Melbourne Vic 8006 (Australia); Metcalfe, P. [Centre for Medical Radiation Physics-University of Wollongong, Northfileds Avenue, Wollongong 2500 NSW (Australia); Zaider, M. [Memorial Sloan-Kettering Cancer Centre, New York, NY 10021 (United States); Rosenfeld, A.B., E-mail: anatoly@uow.edu.au [Centre for Medical Radiation Physics-University of Wollongong, Northfileds Avenue, Wollongong 2500 NSW (Australia)

    2011-05-15

    Treatment of ocular cancers using eye plaque brachytherapy is now an established medical procedure. However, current QA for these eye plaques is quite rudimentary, limiting the opportunities for precise pre-tumour plaque customisation. This paper proposes and experimentally validates a new technique for imaging of eye plaque dose distributions using a high-resolution pixelated silicon detector. Results are presented demonstrating the 2D and 3D isodose surfaces produced using experimental data collected using this method.

  6. Three-dimensional dosimetry imaging of I-125 plaque for eye cancer treatment

    International Nuclear Information System (INIS)

    Weaver, M.; Green, J.; Petasecca, M.; Lerch, M.L.F.; Cutajar, D.; Franklin, D.; Jakubek, J.; Carolan, M.G.; Conway, M.; Pospisil, S.; Kron, T.; Metcalfe, P.; Zaider, M.; Rosenfeld, A.B.

    2011-01-01

    Treatment of ocular cancers using eye plaque brachytherapy is now an established medical procedure. However, current QA for these eye plaques is quite rudimentary, limiting the opportunities for precise pre-tumour plaque customisation. This paper proposes and experimentally validates a new technique for imaging of eye plaque dose distributions using a high-resolution pixelated silicon detector. Results are presented demonstrating the 2D and 3D isodose surfaces produced using experimental data collected using this method.

  7. I-125 ROPES eye plaque dosimetry: validation of a commercial 3D ophthalmic brachytherapy treatment planning system and independent dose calculation software with GafChromic® EBT3 films.

    Science.gov (United States)

    Poder, Joel; Corde, Stéphanie

    2013-12-01

    The purpose of this study was to measure the dose distributions for different Radiation Oncology Physics and Engineering Services, Australia (ROPES) type eye plaques loaded with I-125 (model 6711) seeds using GafChromic(®) EBT3 films, in order to verify the dose distributions in the Plaque Simulator™ (PS) ophthalmic 3D treatment planning system. The brachytherapy module of RADCALC(®) was used to independently check the dose distributions calculated by PS. Correction factors were derived from the measured data to be used in PS to account for the effect of the stainless steel ROPES plaque backing on the 3D dose distribution. Using GafChromic(®) EBT3 films inserted in a specially designed Solid Water™ eye ball phantom, dose distributions were measured three-dimensionally both along and perpendicular to I-125 (model 6711) loaded ROPES eye plaque's central axis (CAX) with 2 mm depth increments. Each measurement was performed in full scatter conditions both with and without the stainless steel plaque backing attached to the eye plaque, to assess its effect on the dose distributions. Results were compared to the dose distributions calculated by Plaque Simulator™ and checked independently with RADCALC(®). The EBT3 film measurements without the stainless steel backing were found to agree with PS and RADCALC(®) to within 2% and 4%, respectively, on the plaque CAX. Also, RADCALC(®) was found to agree with PS to within 2%. The CAX depth doses measured using EBT3 film with the stainless steel backing were observed to result in a 4% decrease relative to when the backing was not present. Within experimental uncertainty, the 4% decrease was found to be constant with depth and independent of plaque size. Using a constant dose correction factor of T = 0.96 in PS, where the calculated dose for the full water scattering medium is reduced by 4% in every voxel in the dose grid, the effect of the plaque backing was accurately modeled in the planning system. Off-axis profiles

  8. Statistical differences and systematic effect on measurement procedure in thermoluminescent dosimetry of the Iodine-125 brachytherapy seed

    International Nuclear Information System (INIS)

    Zeituni, Carlos A.; Moura, Eduardo S.; Rostelato, Maria Elisa C.M.; Manzoli, Jose E.; Moura, Joao Augusto; Feher, Anselmo; Karam, Dib

    2009-01-01

    In order to provide the dosimetry for Iodine-125 seed production in Brazil, Harshaw thermoluminescent dosimeters (TLD-100) will be used. Even if measurements with TLD-100 of the same batch of fabrication are performed, the response will not be the same. As a consequence, they must be measured one by one. These dosimeters are LiF type with a micro-cube (1 mm x 1 mm x 1 mm) shape. Irradiations were performed using Iodine-125 seeds to guarantee the same absorbed dose of 5 Gy in each dosimeter. It has been used a Solid Water Phantom with three concentrically circle with 20 mm, 50 mm and 70 mm diameters. The angle of positions used was 0 deg, 30 deg, 60 deg and 90 deg. Of course there are 2 positions in 0 deg and 90 deg and 4 positions in 30 deg and 60 deg. These complete procedures were carried out five times in order to compare the data and minimize the systematic error. The iodine-125 seed used in the experiment was take off in each measure and put again turning his position 180 deg to guarantee the systematic error was minimized. This paper presents also a little discussion about the statistical difference in the measurement and the calculation procedure to determine the systematic error in these measurements. (author)

  9. Statistical differences and systematic effect on measurement procedure in thermoluminescent dosimetry of the Iodine-125 brachytherapy seed

    Energy Technology Data Exchange (ETDEWEB)

    Zeituni, Carlos A.; Moura, Eduardo S.; Rostelato, Maria Elisa C.M.; Manzoli, Jose E.; Moura, Joao Augusto; Feher, Anselmo, E-mail: czeituni@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP) Sao Paulo, SP (Brazil); Karam, Dib [Universidade de Sao Paulo (USP Leste), Sao Paulo, SP (Brazil). Escola de Artes, Ciencias e Humanidades

    2009-07-01

    In order to provide the dosimetry for Iodine-125 seed production in Brazil, Harshaw thermoluminescent dosimeters (TLD-100) will be used. Even if measurements with TLD-100 of the same batch of fabrication are performed, the response will not be the same. As a consequence, they must be measured one by one. These dosimeters are LiF type with a micro-cube (1 mm x 1 mm x 1 mm) shape. Irradiations were performed using Iodine-125 seeds to guarantee the same absorbed dose of 5 Gy in each dosimeter. It has been used a Solid Water Phantom with three concentrically circle with 20 mm, 50 mm and 70 mm diameters. The angle of positions used was 0 deg, 30 deg, 60 deg and 90 deg. Of course there are 2 positions in 0 deg and 90 deg and 4 positions in 30 deg and 60 deg. These complete procedures were carried out five times in order to compare the data and minimize the systematic error. The iodine-125 seed used in the experiment was take off in each measure and put again turning his position 180 deg to guarantee the systematic error was minimized. This paper presents also a little discussion about the statistical difference in the measurement and the calculation procedure to determine the systematic error in these measurements. (author)

  10. Study and development of methodology for radioactive iodine fixation in polymeric substrate for manufacturing sources used in brachytherapy

    International Nuclear Information System (INIS)

    Rodrigues, Bruna T.; Souza, Carla D.; Benega, Marcos A.G. and others

    2014-01-01

    According global estimates of Globocan 2012 project of the International Agency for Research of Cancer, of the World Health Organization, there were 14,1 million new cases of cancer and a total of 8,2 million deaths from cancer. Also show that in 2030, the overall load will be 21,4 million new cases and 13,2 million cancer deaths. One of the prostate cancer therapy is brachytherapy, used in early and middle stages of the disease. It is made with the introduction of seeds with radioactive material within the tumor or in nearby regions, affecting the minimum surrounding tissues. The aim of this work is the study and developing the deposition of radioactive iodine on the polymeric substrate method, and an analysis relating the efficiency of the method to implementation in the laboratory of brachytherapy from IPEN. Iodine-125 is adsorbed on an epoxy resin solution. The objective of this study is to offer a new proposal for seeds. The results will give the data for the radiation protection and the procedures for radioactive waste management

  11. Changes in the micromorphology of the corneal subbasal nerve plexus in patients after plaque brachytherapy

    International Nuclear Information System (INIS)

    Zhivov, Andrey; Winter, Karsten; Peschel, Sabine; Stachs, Oliver; Wree, Andreas; Hildebrandt, Guido; Guthoff, Rudolf

    2013-01-01

    To quantify the development of radiation neuropathy in corneal subbasal nerve plexus (SNP) after plaque brachytherapy, and the subsequent regeneration of SNP micromorphology and corneal sensation. Nine eyes of 9 melanoma patients (ciliary body: 3, iris: 2, conjunctiva: 4) underwent brachytherapy (ruthenium-106 plaque, dose to tumour base: 523 ± 231 Gy). SNP micromorphology was assessed by in-vivo confocal microscopy. Using software developed in–house, pre-irradiation findings were compared with those obtained after 3 days, 1, 4 and 7 months, and related to radiation dose and corneal sensation. After 3 days nerve fibres were absent from the applicator zone and central cornea, and corneal sensation was abolished. The earliest regenerating fibres were seen at the one-month follow-up. By 4 months SNP structures had increased to one-third of pre-treatment status (based on nerve fibre density and nerve fibre count), and corneal sensation had returned to approximately two-thirds of pre-irradiation values. Regeneration of SNP and corneal sensation was nearly complete 7 months after plaque brachytherapy. The evaluation of SNP micromorphology and corneal sensation is a reliable and clinically useful method for assessing neuropathy after plaque brachytherapy. Radiation-induced neuropathy of corneal nerves develops quickly and is partly reversible within 7 months. The clinical impact of radiation-induced SNP damage is moderate

  12. I-125 ROPES eye plaque dosimetry: Validation of a commercial 3D ophthalmic brachytherapy treatment planning system and independent dose calculation software with GafChromic{sup ®} EBT3 films

    Energy Technology Data Exchange (ETDEWEB)

    Poder, Joel; Corde, Stéphanie [Department of Radiation Oncology, Prince of Wales Hospital, Randwick, NSW 2031 (Australia)

    2013-12-15

    Purpose: The purpose of this study was to measure the dose distributions for different Radiation Oncology Physics and Engineering Services, Australia (ROPES) type eye plaques loaded with I-125 (model 6711) seeds using GafChromic{sup ®} EBT3 films, in order to verify the dose distributions in the Plaque Simulator™ (PS) ophthalmic 3D treatment planning system. The brachytherapy module of RADCALC{sup ®} was used to independently check the dose distributions calculated by PS. Correction factors were derived from the measured data to be used in PS to account for the effect of the stainless steel ROPES plaque backing on the 3D dose distribution.Methods: Using GafChromic{sup ®} EBT3 films inserted in a specially designed Solid Water™ eye ball phantom, dose distributions were measured three-dimensionally both along and perpendicular to I-125 (model 6711) loaded ROPES eye plaque's central axis (CAX) with 2 mm depth increments. Each measurement was performed in full scatter conditions both with and without the stainless steel plaque backing attached to the eye plaque, to assess its effect on the dose distributions. Results were compared to the dose distributions calculated by Plaque Simulator™ and checked independently with RADCALC{sup ®}.Results: The EBT3 film measurements without the stainless steel backing were found to agree with PS and RADCALC{sup ®} to within 2% and 4%, respectively, on the plaque CAX. Also, RADCALC{sup ®} was found to agree with PS to within 2%. The CAX depth doses measured using EBT3 film with the stainless steel backing were observed to result in a 4% decrease relative to when the backing was not present. Within experimental uncertainty, the 4% decrease was found to be constant with depth and independent of plaque size. Using a constant dose correction factor of T= 0.96 in PS, where the calculated dose for the full water scattering medium is reduced by 4% in every voxel in the dose grid, the effect of the plaque backing was

  13. Feasibility and clinical value of CT-guided {sup 125}I brachytherapy for metastatic soft tissue sarcoma after first-line chemotherapy failure

    Energy Technology Data Exchange (ETDEWEB)

    Mo, Zhiqiang; Zhang, Yanling; Xiang, Zhanwang; Yan, Huzhen; Zhong, Zhihui; Gao, Fei; Zhang, Fujun [Sun Yat-Sen University Cancer Centre, State Key Laboratory of Oncology in South China, Collaborative Innovation Centre for Cancer Medicine, Guangzhou (China); Zhang, Tao [Guangzhou Medical University, Department of Interventional Radiology and Vascular Anomalies, Guangzhou Women and Children' s Medical Centre, Guangzhou (China)

    2018-03-15

    To evaluate the feasibility and usefulness of computed tomography (CT)-guided iodine{sup 125} ({sup 125}I) brachytherapy for patients with metastatic soft tissue sarcoma (STS) after first-line chemotherapy failure. We recruited 93 patients with metastatic STS who had received first-line chemotherapy 4-6 times but developed progressive disease, from January 2010 to July 2015; 45 patients who had combined {sup 125}I brachytherapy and second-line chemotherapy (Group A), and 48 patients who received second-line CT only (Group B). In Group A, 49 {sup 125}I seed implantation procedures were performed in 45 patients with 116 metastatic lesions; the primary success rate was 91.1% (41/45), without life-threatening complications. Local control rates at 3, 6, 12, 24 and 36 months were 71.1%, 62.2%, 46.7%, 28.9% and 11.1% for Group A, and 72.9%, 54.2%, 18.8%, 6.3% and 0% for Group B. Mean progression-free survival differed significantly (Group A: 7.1±1.3 months; Group B: 3.6 ±1.1 months; P<0.001; Cox proportional hazards regression analysis), but overall survival did not significantly differ (Group A: 16.9 ±5.1 months; Group B: 12.1 ± 4.8 months). Group A showed better symptom relief and quality of life than Group B. CT-guided {sup 125}I brachytherapy is a feasible and valuable treatment for patients with metastatic STS. (orig.)

  14. Tratamento conservador ocular dos melanomas de coróide com braquiterapia utilizando placas de iodo-125 Conservative treatment of choroidal melanomas using iodine brachytherapy

    Directory of Open Access Journals (Sweden)

    Antônio Cássio Assis Pellizzon

    2004-08-01

    Full Text Available OBJETIVO: Avaliar, retrospectivamente, o resultado do tratamento conservador do melanoma de coróide, por meio de braquiterapia, usando placas episclerais de iodo-125 (modelo 6711, Amershan. MATERIAIS E MÉTODOS: Foram avaliados 49 pacientes portadores de melanoma de coróide tratados no Hospital do Câncer, São Paulo, SP, de março de 2001 a janeiro de 2003. Os seguintes parâmetros foram analisados e correlacionados ao controle local e sobrevida: sexo, idade, dimensões da lesão, tempo de tratamento e doses no ápice e base das lesões. RESULTADOS: Com diâmetro máximo da base do tumor de 17 mm e altura máxima de 12 mm, observamos que as doses na base do tumor variaram de 213 a 463 Gy (mediana de 347 Gy e no ápice, de 51 a 250 Gy (mediana de 91 Gy. As taxas de preservação ocular, sobrevida livre de doença e conservação ocular, atuariais em dois anos, foram de 96%, 93,5% e 96,3%, respectivamente. Através de análise univariada, o único fator prognóstico para controle local nesta análise foi a altura do tumor menor que 6 mm (p = 0,0348. CONCLUSÃO: A braquiterapia levou a uma taxa bastante satisfatória de controle local, confirmando que a altura do tumor é um dos fatores prognósticos importantes desse parâmetro.OBJECTIVE: To retrospectively evaluate the results of conservative therapy using episcleral iodine-125 (model 6711, Amershan plaque for brachytherapy of choroidal melanoma. MATERIALS AND METHODS: We evaluated 49 patients with choroidal melanoma treated at "Hospital do Câncer", São Paulo, Brazil, from March 2001 to January 2003. The following clinical parameters were analyzed and correlated with local control and survival rate: gender, age, lesion dimension, treatment duration, as well as doses in apex and base of the tumors. RESULTS: The maximum diameter and height of the base of the tumors treated were 17 mm and 12 mm, respectively. Doses at those points ranged from 213 to 463 Gy (median: 347 Gy and 51 to 250 Gy

  15. Role of TPS in 125I brachytherapy for orbital tumors

    International Nuclear Information System (INIS)

    Ren Ling; Dai Haojie; Li Quan

    2012-01-01

    Objective: To investigate the role of TPS in 125 I brachytherapy for orbital tumors. Methods: Sixty-six patients with orbital tumor treated with 125 I seeds from 2005 to 2009 were retrospectively analyzed. Forty-three patients were treated using TPS guided brachytherapy and the prescribed dose was 140 Gy. Other 23 patients were treated without TPS but simply implanted with 125 I seeds at 1 cm intervals in parallel with each other intraoperatively. CT and TPS quality verification were performed postoperatively in all patients. Also, CT and (or) MRI examination were performed at 3, 6, 12 and 24 months after brachytherapy for follow-up. χ 2 test and Kaplan-Meier survival analysis with log-rank significance test were used with SPSS 17.0. Results: A total of 1070 125 I seeds were implanted in 66 cases, on average, (16.2 ± 7.3) seeds for each patient. The satisfaction rates of postoperative quality verification in patients with and without TPS pre-plans were 79.07% (34/43) and 43.48% (10/23) respectively (χ 2 =8.542, P=0.003). Ten patients were lost in follow-up. Local recurrence rates in patients with favorable postoperative quality verification were 0 (0/37) in 3 months, 6.25% (2/32) in 6 months, 13.64% (3/22) in 12 months and 3/9 in 24 months respectively, which were significantly different from those (5.26% (1/19), 16.67% (3/18), 30.77% (4/13), 6/6) in the patients with inferior postoperative quality verification (χ 2 =9.017, P=0.0003). Conclusions: TPS plays an important role in 125 I brachytherapy for orbital tumors. Also, postoperative quality verification by TPS may help predict the local recurrence after brachytherapy. (authors)

  16. Iodine-125 and Iodine-131 in the Thames Valley and other areas

    International Nuclear Information System (INIS)

    Howe, J.R.; Lloyd, M.K.; Bowlt, C.

    1985-01-01

    Part of the Iodine-125 and Iodine-131 waste from hospitals and research centres is discarded down drains and passes through sewage and water reclamation works into the river system. Relatively high concentration of radioiodine occur in outfalls that discharge into the river Thames, lower levels are found in the mainstream river and less still in the reservoirs and tap water supplies abstracted from the river. The pathway from waste to drinking water could account for the low levels of Iodine-125 found in the thyroid glands of some farm animals and human beings in the Thames valley

  17. Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Samia de Freitas, E-mail: samiabrandao@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Campos, Tarcisio Passos Ribeiro de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2013-06-15

    Objective: comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and methods: simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results: intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h{sup -1}.p{sup -1}.s, respectively, on the healthy tissue, on the balloon periphery and on the /{sub 1} and /{sub 2} tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h{sup -1}.p{sup -1}.s, respectively on the healthy tissue, on the target tumor and on the /{sub 1} and /{sub 2} infiltration zones. Conclusion: Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones. (author)

  18. Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors

    Directory of Open Access Journals (Sweden)

    Samia de Freitas Brandao

    2013-07-01

    Full Text Available Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones.

  19. Prostate-Specific Antigen Bounce After Permanent Iodine-125 Prostate Brachytherapy-An Australian Analysis

    International Nuclear Information System (INIS)

    Zwahlen, Daniel R.; Smith, Ryan; Andrianopoulos, Nick; Matheson, Bronwyn; Royce, Peter; Millar, Jeremy L.

    2011-01-01

    Purpose: To report on prostate-specific antigen (PSA) 'bounces' after 125 I prostate brachytherapy to review the relationship to biochemical control and correlate both clinical and dosimetric variables. Methods and Materials: We analyzed 194 hormone-naive patients with a follow-up of ≥3 years. Four bounce definitions were applied: an increase of ≥0.2 ng/mL (definition I), ≥0.4 ng/mL (definition II), ≥15% (definition III), and ≥35% (definition IV) of a previous value with spontaneous return to the prebounce level or lower. Results: Using definition I, II, III, and IV, a bounce was detected in 50%, 34%, 11%, and 9% of patients, respectively. The median time to onset was 14-16 months, the duration was 12-21.5 months, and the magnitude of the increase was 0.5-2 ng/mL. A magnitude of >2 ng/mL, fulfilling the criteria for biochemical failure (BF) according to the American Society for Therapeutic Radiology and Oncology Phoenix definition, was detected in 11.3%, 16.9%, 47.6%, and 50% using definitions I, II, III, and IV, respectively; 11 patients (5.7%) had true BF. The PSA bounces occurred earlier than BF (p < 0.001). The prediction of BF remains controversial and is probably unrelated to biochemical control. The only statistically significant factor predictive of a PSA bounce was younger age (definitions I and II). Conclusion: PSA bounces are common after brachytherapy. All definitions resulted in a high number of false-positive calls for BF during the first 2 years. The definition of an increase of ≥0.2 ng/mL should be preferred because of the lowest number of false-positive results for BF. Patients experiencing a PSA bounce during the first 2 years after brachytherapy should undergo surveillance every 3-6 months. Additional investigations are recommended for elevated postimplant PSA levels that have not corrected by 3 years of follow-up.

  20. SU-E-T-635: Process Mapping of Eye Plaque Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Huynh, J; Kim, Y [University of Arizona, Tucson, AZ (United States)

    2015-06-15

    Purpose: To apply a risk-based assessment and analysis technique (AAPM TG 100) to eye plaque brachytherapy treatment of ocular melanoma. Methods: The role and responsibility of personnel involved in the eye plaque brachytherapy is defined for retinal specialist, radiation oncologist, nurse and medical physicist. The entire procedure was examined carefully. First, major processes were identified and then details for each major process were followed. Results: Seventy-one total potential modes were identified. Eight major processes (corresponding detailed number of modes) are patient consultation (2 modes), pretreatment tumor localization (11), treatment planning (13), seed ordering and calibration (10), eye plaque assembly (10), implantation (11), removal (11), and deconstruction (3), respectively. Half of the total modes (36 modes) are related to physicist while physicist is not involved in processes such as during the actual procedure of suturing and removing the plaque. Conclusion: Not only can failure modes arise from physicist-related procedures such as treatment planning and source activity calibration, but it can also exist in more clinical procedures by other medical staff. The improvement of the accurate communication for non-physicist-related clinical procedures could potentially be an approach to prevent human errors. More rigorous physics double check would reduce the error for physicist-related procedures. Eventually, based on this detailed process map, failure mode and effect analysis (FMEA) will identify top tiers of modes by ranking all possible modes with risk priority number (RPN). For those high risk modes, fault tree analysis (FTA) will provide possible preventive action plans.

  1. Development of computational models for the simulation of isodose curves on dosimetry films generated by iodine-125 brachytherapy seeds

    International Nuclear Information System (INIS)

    Santos, Adriano M.; Meira-Belo, Luiz C.; Reis, Sergio C.; Grynberg, Suely E.

    2011-01-01

    The interstitial brachytherapy is one modality of radiotherapy in which radioactive sources are placed directly in the region to be treated or close to it. The seeds that are used in the treatment of prostate cancer are generally cylindrical radioactive sources, consisting of a ceramic or metal matrix, which acts as the carrier of the radionuclide and as the X-ray marker, encapsulated in a sealed titanium tube. This study aimed to develop a computational model to reproduce the film-seed geometry, in order to obtain the spatial regions of the isodose curves produced by the seed when it is put over the film surface. The seed modeled in this work was the OncoSeed 6711, a sealed source of iodine-125, which its isodose curves were obtained experimentally in previous work with the use of dosimetric films. For the films modeling, compositions and densities of the two types of dosimetric films were used: Agfa Personal Monitoring photographic film 2/10, manufactured by Agfa-Geavaert; and the model EBT radiochromic film, by International Specialty Products. The film-seed models were coupled to the Monte Carlo code MCNP5. The results obtained by simulations showed to be in good agreement with experimental results performed in a previous work. This indicates that the computational model can be used in future studies for other seeds models. (author)

  2. Development of computational models for the simulation of isodose curves on dosimetry films generated by iodine-125 brachytherapy seeds

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Adriano M.; Meira-Belo, Luiz C.; Reis, Sergio C.; Grynberg, Suely E., E-mail: amsantos@cdtn.b [Center for Development of Nuclear Technology (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    The interstitial brachytherapy is one modality of radiotherapy in which radioactive sources are placed directly in the region to be treated or close to it. The seeds that are used in the treatment of prostate cancer are generally cylindrical radioactive sources, consisting of a ceramic or metal matrix, which acts as the carrier of the radionuclide and as the X-ray marker, encapsulated in a sealed titanium tube. This study aimed to develop a computational model to reproduce the film-seed geometry, in order to obtain the spatial regions of the isodose curves produced by the seed when it is put over the film surface. The seed modeled in this work was the OncoSeed 6711, a sealed source of iodine-125, which its isodose curves were obtained experimentally in previous work with the use of dosimetric films. For the films modeling, compositions and densities of the two types of dosimetric films were used: Agfa Personal Monitoring photographic film 2/10, manufactured by Agfa-Geavaert; and the model EBT radiochromic film, by International Specialty Products. The film-seed models were coupled to the Monte Carlo code MCNP5. The results obtained by simulations showed to be in good agreement with experimental results performed in a previous work. This indicates that the computational model can be used in future studies for other seeds models. (author)

  3. Characterization and storage of liquid wastes containing 125Iodine in the laboratory for production of brachytherapy sources - IPEN

    International Nuclear Information System (INIS)

    Carvalho, Vitória S.; Souza, Daiane C.B. de; Barbosa, Nayane K.O.; Rodrigues, Bruna T.; Nogueira, Beatriz R.; Costa, Osvaldo L. da; Zeituni, Carlos A.; Vicente, Roberto; Rostelato, Maria E.C.M.

    2017-01-01

    Radioactive sources of Iodine-125 for medical applications have been developed at the Institute for Energy and Nuclear Research (IPEN) to meet the growing demand for medical applications such as brachytherapy. A dedicated laboratory is already being implemented at IPEN. Part of the processes involved in the production of sealed sources generate radioactive wastes that despite the short half-life (<100 days) have radioactive activity above the levels of exemption established by the Brazilian National Nuclear Energy Commission. Therefore, these wastes should receive appropriate treatment and storage until they reach the levels of release into the environment. This work aims to determine the volumes of the liquid wastes generated during the production stages of the sources, as well as to propose a temporary storage system for such wastes. The applied methodology consisted in determining the volumes of wastes generated in each production cell according to the manufacturing steps. After that, activities and activity concentrations were calculated for each container used for temporary storage inside the production laboratory. The total volume stored for one year in the temporary storage, as well as the rate of entry and exit of the liquid wastes were calculated according to the source production demand and the decay time of the radionuclide, respectively. The main results showed that the time required to reach sanitary sewage disposal values is within the period of operation of the facility. The total volume generated is also within the facility's temporary storage capacity

  4. Postoperative [{sup 125}I] seed brachytherapy in the treatment of acinic cell carcinoma of the parotid gland. With associated risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Ming-hui; Zhang, Jian-Guo; Zhang, Jie; Zheng, Lei; Liu, Shu-ming; Huang, Ming-wei; Shi, Yan [Peking Univ. School and Hospital of Stomatology, Beijing (China). Dept. of Oral and Maxillofacial Surgery

    2014-11-15

    This retrospective study was undertaken to analyze data from patients receiving iodine-125 ([{sup 125}I]) seed brachytherapy postoperatively for the treatment of acinic cell carcinoma (ACC) of the parotid gland along with the following risk factors: residual tumor, recurrent tumor, facial nerve invasion, positive resection margins, advanced tumor stage, or tumor spillage. Twenty-nine patients with ACC (17 females, 12 males; age range, 13-73 years; median age, 37.3 years) were included. Median follow-up was 58.2 months (range, 14-122 months). Patients received [{sup 125}I] seed brachytherapy (median actuarial D90, 177 Gy) 3-41 days (median, 14 days) following surgery. Radioactivity was 18.5-33.3 MBq per seed, and the prescription dose was 80-120 Gy. The 3-, 5-, and 10-year rates of local control were 93.1, 88.7, and 88.7 %, respectively; overall survival was 96.6, 92, and 92 %; disease-free survival was 93.1, 88.4, and 88.4 %; and freedom from distant metastasis was 96.6, 91.2, and 91.2 %. Lymph node metastases were absent in all patients, although two patients died with distant metastases. Facial nerve recovery was quick, and no severe radiotherapy-related complications were noted. Recurrence history, local recurrence, and distant metastasis significantly affected overall survival. Postoperative [{sup 125}I] seed brachytherapy is effective in treating ACC and has minor complications. Patients with a history of recurrence showed poor prognosis and were more likely to experience disease recurrence and develop metastases. (orig.) [German] Diese retrospektive Studie wurde durchgefuehrt, um die Daten von Patienten zu analysieren, die postoperativ eine Seed-Brachytherapie mit Iod-125 ([{sup 125}I]) zur Behandlung von Azinuszellkarzinomen der Ohrspeicheldruese mit begleitenden Risikofaktoren, wie Residualtumor, Rezidivtumor, Invasion in den N. facialis, positive (= nicht tumorfreie) Resektionsraender, fortgeschrittenes Tumorstadium oder lokale Verbreitung von Tumorzellen

  5. Study of isodose curves of an eye brachytherapy plaque

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Marcos R.O.; Mourao, Arnaldo P., E-mail: marcos.robertto@hotmail.com, E-mail: seg@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Grynberg, Suely E., E-mail: aprata@des.cefetmg.br [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar

    2015-07-01

    The use eye plaque brachytherapy for intraocular tumors treatment is a process designed to protect healthy eye structures, as well as visual functions. It replaces enucleation when possible. The knowledge of the dose spatial distribution inside the eyeball and adjacent structures is very important to obtain the therapeutic dose, minimize the side effects and ensure efficiency in the process. Small variations in positioning the plaque on the ocular surface may generate a less effective treatment. Thus, in this work an eyeball phantom and a seed accommodation system similar to a commercially eye plaque model ROPES with diameter of 15 mm, were developed both in solid water Gammex 457 to conduct the study of the possible variation in the dose deposition inside the eye phantom. Radiochromic films were used to record isodose curves of two orthogonal plans within the simulator. The results showed that there is a difference in the dose deposition for the two orthogonal plans studied. This difference is 8.33% higher for the maximum dose value. Thus, a difference in dose that occurs due to the asymmetrical distribution of seeds on the eye plaque may interfere with the treatment, making it less effective. (author)

  6. Study of isodose curves of an eye brachytherapy plaque

    International Nuclear Information System (INIS)

    Costa, Marcos R.O.; Mourao, Arnaldo P.; Grynberg, Suely E.

    2015-01-01

    The use eye plaque brachytherapy for intraocular tumors treatment is a process designed to protect healthy eye structures, as well as visual functions. It replaces enucleation when possible. The knowledge of the dose spatial distribution inside the eyeball and adjacent structures is very important to obtain the therapeutic dose, minimize the side effects and ensure efficiency in the process. Small variations in positioning the plaque on the ocular surface may generate a less effective treatment. Thus, in this work an eyeball phantom and a seed accommodation system similar to a commercially eye plaque model ROPES with diameter of 15 mm, were developed both in solid water Gammex 457 to conduct the study of the possible variation in the dose deposition inside the eye phantom. Radiochromic films were used to record isodose curves of two orthogonal plans within the simulator. The results showed that there is a difference in the dose deposition for the two orthogonal plans studied. This difference is 8.33% higher for the maximum dose value. Thus, a difference in dose that occurs due to the asymmetrical distribution of seeds on the eye plaque may interfere with the treatment, making it less effective. (author)

  7. Quantification of iodine in porous hydroxyapatite matrices for application as radioactive sources in brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, Kassio Andre; Lameiras, Fernando Soares [Centro de Desenvolvimento da Tecnologia Nuclear, (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Silva, Viviane Viana [Centro de Desenvolvimento da Tecnologia Nuclear, (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Universidade Vale do Rio Verde de Tres Coracoes, MG (Brazil)

    2007-07-15

    In this study, non-radioactive iodine was incorporated in two types of biodegradable hydroxyapatite-based porous matrices (HA and HACL) through impregnation process from sodium iodine aqueous solutions with varying concentrations (0.5 and 1.0 mol/L) . The results revealed that both systems presented a high capacity of incorporating iodine into their matrices. The quantity of incorporated iodine was measured through Neutron Activation Analysis (NAA). The porous ceramic matrices based on hydroxyapatite demonstrated a great potential for uses in low dose rate (LDR) brachytherapy. (author)

  8. Use of iodine-125 brachytherapy in treatment of choroidal melanomas, technic and preliminary analysis of 78 patients

    International Nuclear Information System (INIS)

    Quetin, P.; Schumacher, C.; Schraub, S.; Meyer, L.; Polto, F.; Sahel, J.; Magnenet, P.; Andres, E.

    2001-01-01

    Purpose. - Iodine 125 curietherapy is one of the conservative treatments of uveal melanoma. The technique used to achieve these results was simplified through the physical characteristics of the radioelement and the optimized-dosimetry program employed. Patients and methods. - 78 patients with choroidal melanoma were treated with iodine 125. About 100 Gy were delivered to the superior pole of the tumour. The minimal length of follow-up was 17 months and the average, 67 months. Results. -There was 88% local control, leading to lowered visual acuity in 76 % of the cases. Radiation retinopathy, directly related to proximity to the macula, is the principle etiology. Seven patients died of hepatic metastasis, five patients were enucleated. Four patients were further treated with proton-therapy to make up for non-control locally. Conclusion. -One dose of 100 Gy to the superior pole of the tumor seemed to lead to good local control, with the exception of complications related to proximity to the macula and the optic nerve. In this attempt to optimize irradiation, the time lapse between any benefit in local control derived from irradiation and post-therapeutic complications observed remains insufficient to evaluate any relationship. (authors)

  9. Iodine-125 Seeds Strand for Treatment of Tumor Thrombus in Inferior Vena Cava: An Experimental Study in a Rabbit Model

    International Nuclear Information System (INIS)

    Zhang, Wen; Yan, Zhiping; Luo, Jianjun; Fang, Zhuting; Wu, Linlin; Liu, QingXin; Qu, Xudong; Liu, Lingxiao; Wang, Jianhua

    2013-01-01

    Objective: The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. Methods: Tumor cell line VX 2 was inoculated subcutaneously into New Zealand rabbit to develop the parent tumor. The tumor strip was inoculated into inferior vena cava (IVC) to establish the IVCTT model. The IVCTT was confirmed by multidetector computed tomography (MDCT) after 2 weeks. Twelve rabbits with IVCTT were randomly divided into two groups. Treatment group (group T; n = 6) underwent Iodine-125 seeds brachytherapy, and the control group (group C; n = 6) underwent blank seeds strand. The blood laboratory examination (including blood routine examination, hepatic and renal function), body weight, survival time, and IVCTT volume by MDCT were monitored. All rabbits were dissected postmortem, and the therapeutic effects were evaluated on the basis of histopathology. The proliferating cell nuclear antigen index (PI) and apoptosis index (AI) of IVCTT were compared between two groups. T test, Wilcoxon rank test, and Kaplan–Meier survival curve analysis were used. Results: The success rate of establishing IVCTT was 100 %. The body weight loss and cachexia of rabbits in group C appeared earlier than in group T. Body weight in the third week, the mean survival time, PI, AI in groups T and C were 2.23 ± 0.12 kg, 57.83 ± 8.68 days, (16.73 ± 5.18 %), (29.47 ± 7.18 %), and 2.03 ± 0.13 kg, 43.67 ± 5.28 days, (63.01 ± 2.01 %), (6.02 ± 2.93 %), respectively. There were statistically significant differences between group T and group C (P < 0.05). The IVCTT volume of group T was remarkably smaller than that of group C. Conclusions: Injecting and suspensory fixing VX2 tumor strip into IVC is a reliable method to establish IVCTT animal model. The linear Iodine-125 seeds strand brachytherapy was a safe and effective method for treating IVCTT in rabbit model

  10. Iodine-125 Seeds Strand for Treatment of Tumor Thrombus in Inferior Vena Cava: An Experimental Study in a Rabbit Model

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wen; Yan, Zhiping; Luo, Jianjun; Fang, Zhuting; Wu, Linlin; Liu, QingXin; Qu, Xudong; Liu, Lingxiao; Wang, Jianhua [Fudan University, Department of Interventional Radiology, Zhongshan Hospital (China)

    2013-10-15

    Objective: The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. Methods: Tumor cell line VX{sub 2} was inoculated subcutaneously into New Zealand rabbit to develop the parent tumor. The tumor strip was inoculated into inferior vena cava (IVC) to establish the IVCTT model. The IVCTT was confirmed by multidetector computed tomography (MDCT) after 2 weeks. Twelve rabbits with IVCTT were randomly divided into two groups. Treatment group (group T; n = 6) underwent Iodine-125 seeds brachytherapy, and the control group (group C; n = 6) underwent blank seeds strand. The blood laboratory examination (including blood routine examination, hepatic and renal function), body weight, survival time, and IVCTT volume by MDCT were monitored. All rabbits were dissected postmortem, and the therapeutic effects were evaluated on the basis of histopathology. The proliferating cell nuclear antigen index (PI) and apoptosis index (AI) of IVCTT were compared between two groups. T test, Wilcoxon rank test, and Kaplan-Meier survival curve analysis were used. Results: The success rate of establishing IVCTT was 100 %. The body weight loss and cachexia of rabbits in group C appeared earlier than in group T. Body weight in the third week, the mean survival time, PI, AI in groups T and C were 2.23 {+-} 0.12 kg, 57.83 {+-} 8.68 days, (16.73 {+-} 5.18 %), (29.47 {+-} 7.18 %), and 2.03 {+-} 0.13 kg, 43.67 {+-} 5.28 days, (63.01 {+-} 2.01 %), (6.02 {+-} 2.93 %), respectively. There were statistically significant differences between group T and group C (P < 0.05). The IVCTT volume of group T was remarkably smaller than that of group C. Conclusions: Injecting and suspensory fixing VX2 tumor strip into IVC is a reliable method to establish IVCTT animal model. The linear Iodine-125 seeds strand brachytherapy was a safe and effective method for treating IVCTT

  11. Medical physics aspects of ophthalmic brachytherapy

    International Nuclear Information System (INIS)

    Sharma, S.D.; Shanta, A.; Palani Selvam, T.; Tripathi, U.B.; Bhatt, B.C.

    2004-11-01

    Intraocular melanoma is the most common primary malignancy of the eye. Radiation therapy using ophthalmic plaque has proved successful in the management of various ocular lesions. Although a few centres were using 90 Sr/ 90 Y plaques for shallow turtlours some years ago, eye plaque therapy was not a common practice in India. A revived interest in the use of eye plaque therapy and very high cost of imported sources has led to the development and production of 125 I seed sources by the Radiopharmaceuticals Division, BARC. This report presents a brief description on the clinical, dosimetry and radiation safety aspects of 90 Sr/ 90 Y and 106 Ru/ 106 Rh beta ray and 125 I gamma ray eye plaque applicators. This report has been divided in five Sections. Section I presents general introduction of ophthalmic brachytherapy including the structure of a human eye, types of ophthalmic plaques and characteristics of radioisotopes commonly used in such applications. A brief review of sources, applicators and dosimetry of 90 Sr/ 90 Y and 106 Ru/ 106 Rh beta and 125 I gamma ophthalmic plaques are given in Section II and Section III, respectively. Section IV contains the single seed dosimetry data of BARC OcuProsta 125 I seed as well as dosimetry data of typical eye plaques loaded with BARC OcuProsta 125 I seed. Quality assurance and radiation safety aspects of these eye applicators are described in Section V. A proforma of the application required to be filled in by the user institution for obtaining regulatory consent to start eye plaque therapy has also been appended to this report. (author)

  12. Experimental radiotherapy of the R1H rhabdomyosarcoma of the rat: combined use of interstitial iodine-125-brachytherapy and fractionated X-irradiation

    International Nuclear Information System (INIS)

    Doll, D.

    1995-01-01

    The study described here investigated into the therapeutic effects that split-dose x-radiation combined with interstitial iodine-125 brachytherapy would have on two different lines of the R1H rhabdomyosarcoma of the rat. The following parameters were examined: local tumour control rate; growth delay; net growth delay; position, movement and loss of seeds; tumour shape. The following results were obtained: The local tumour control rate for tumours externally treated with two seeds was by 42 Gy higher than that determined for the group treated with external irradiation alone. A procedure was developed to calculate the most appropriate distance for the seeds on the basis of tumour axes and volumes. The relationship between growth delay and mean maximum distance of the seed from the tumour margin could be ascertained on a quantitative basis. The influence of the tumour shape on the result of treatment was confirmed. Although the seeds were still active at the time of recidivation and treatment was not yet terminated, it was possible to show that the tumour bed effect, which tends to distort the growth delay calculations and may even occur in externally treated seed animals, could largely be avoided in the evaluation of this study. (orig./MG) [de

  13. SU-E-T-259: Particle Swarm Optimization in Radial Dose Function Fitting for a Novel Iodine-125 Seed

    Energy Technology Data Exchange (ETDEWEB)

    Wu, X [University of Alabama at Birmingham, Birmingham, Al (United States); Duan, J; Popple, R; Huang, M; Shen, S; Brezovich, I [University of Alabama Birmingham, Birmingham, AL (United States); Cardan, R [UAB University of Alabama, Birmingham, Birmingham, AL (United States); Benhabib, S [University of Alabama at Birmingham, Birmingham, AL (United States)

    2014-06-01

    Purpose: To determine the coefficients of bi- and tri-exponential functions for the best fit of radial dose functions of the new iodine brachytherapy source: Iodine-125 Seed AgX-100. Methods: The particle swarm optimization (PSO) method was used to search for the coefficients of the biand tri-exponential functions that yield the best fit to data published for a few selected radial distances from the source. The coefficients were encoded into particles, and these particles move through the search space by following their local and global best-known positions. In each generation, particles were evaluated through their fitness function and their positions were changed through their velocities. This procedure was repeated until the convergence criterion was met or the maximum generation was reached. All best particles were found in less than 1,500 generations. Results: For the I-125 seed AgX-100 considered as a point source, the maximum deviation from the published data is less than 2.9% for bi-exponential fitting function and 0.2% for tri-exponential fitting function. For its line source, the maximum deviation is less than 1.1% for bi-exponential fitting function and 0.08% for tri-exponential fitting function. Conclusion: PSO is a powerful method in searching coefficients for bi-exponential and tri-exponential fitting functions. The bi- and tri-exponential models of Iodine-125 seed AgX-100 point and line sources obtained with PSO optimization provide accurate analytical forms of the radial dose function. The tri-exponential fitting function is more accurate than the bi-exponential function.

  14. Seed-migration detector for embolized seeds to the lung in the context of permanent iodine-125 prostate brachytherapy

    International Nuclear Information System (INIS)

    Morrier, J.; Chretien, M.; Beaulieu, L.

    2008-01-01

    Full text: Purpose: To evaluate the efficacy of a seed-migration detector for embolized seeds to the lung in the context of permanent iodine-125 prostate brachytherapy and to compare its performance to fluoroscopy and to the postoperative chest radiographs generally recommended. Materials and Methods: A low energy gamma scintillation survey meter, Victoreen Model 425-110 was used together with a Victoreen count rate meter (model 190). It was converted to a seed-migration detector by adding a shield on the scintillation probe detection window, following the method proposed by Chen and Blair in 2003 [Med Phys 2003;30:785790]. The detector response to three seeds activities of iodine 125 (0.42, 0.22 and 0.06 mCi) was measured for different source-to-detector distances in air and in water. The detector was used to perform a chest evaluation on 579 patients at their first postoperative visit, for a total of 31 826 seeds. When the detector showed activity around a patients chest, it was confirmed by taking an antero-posterior chest radiograph and by looking at the region with fluoroscopy. Results: 79 patients (13.6%) present at least one embolized seed in the chest area. This account for 94 of the 31 826 seeds, that is a 0.30% seed migration rate. Sixty-eight, seven and four patients had respectively a single, two and three seeds embolization. In three cases, a seed had migrated in the kidney, which was confirmed with a CT scan. Of the 94 seeds, 67 (71%) were visible under fluoroscopy and 55 (59%) appeared on the chest radiograph. Rapid movement of the seeds in the chest area, due to breathing or to a location close to the heart or the diaphragm, makes nine seeds to be visible with fluoroscopy but not on the radiograph. This also explains why twenty-seven seeds were not visible with fluoroscopy neither with radiograph. In comparison to the seed-migration detector, detection based on fluoroscopy would have led to twenty-seven false-negative detections while the radiograph

  15. Regression Patterns of Iris Melanoma after Palladium-103 (103Pd) Plaque Brachytherapy.

    Science.gov (United States)

    Chaugule, Sonal S; Finger, Paul T

    2017-07-01

    To evaluate the patterns of regression of iris melanoma after treatment with palladium-103 ( 103 Pd) plaque brachytherapy. Retrospective, nonrandomized, interventional case series. Fifty patients with primary malignant melanoma of the iris. Palladium-103 plaque brachytherapy. Changes in tumor size, pigmentation, and vascularity; incidence of iris neovascularization; and radiation-related complications. The mean age in the case series was 61.2±14.9 years. The mean tumor thickness was 1.4±0.6 mm. According to the American Joint Committee on Cancer, eighth edition, staging criteria for iris melanoma, 21 tumors (42%) were T1a, 5 tumors (10%) were T1b, and 24 tumors (48%) were T2a. The tumor was melanotic in 37 cases (74%) and amelanotic in 13 cases (26%); of these, 13 tumors (26%) showed variable pigmentation. After brachytherapy, mean tumor thickness decreased to 0.9±0.2 mm. Pigmentation increased in 32 tumors (64%), decreased in 11 tumors (22%), and was unchanged in 6 tumors (12%). For intrinsic vascularity (n = 19), 12 tumors (63%) showed decrease and 7 tumors (37%) showed complete resolution. Appearance of ectropion uveae showed diminution in 15 tumors (43%); newly present corectopia was observed in 6 patients (12%). On high-frequency ultrasound imaging, of the 42 tumors (84%) with low to moderate internal reflectivity, 30 tumors (60%) showed an increase in internal reflectivity on regression. Iris stromal atrophy was noted in 26 patients (52%), progression or new-onset cataract was noted in 22 patients (44%), neovascular glaucoma was noted in 1 patient (2%), and there were no cases of corneal opacity. There was no clinical evidence (0%) of radiation-induced retinopathy, maculopathy, or optic neuropathy. Mean follow-up in this series was 5.2 years (range, 0.5-17 years). The most common findings related to iris melanoma regression after 103 Pd plaque brachytherapy included decreased intrinsic tumor vascularity, increased tumor pigmentation, and decreased tumor

  16. Keeping an eye on the ring: COMS plaque loading optimization for improved dose conformity and homogeneity.

    Science.gov (United States)

    Gagne, Nolan L; Cutright, Daniel R; Rivard, Mark J

    2012-09-01

    To improve tumor dose conformity and homogeneity for COMS plaque brachytherapy by investigating the dosimetric effects of varying component source ring radionuclides and source strengths. The MCNP5 Monte Carlo (MC) radiation transport code was used to simulate plaque heterogeneity-corrected dose distributions for individually-activated source rings of 14, 16 and 18 mm diameter COMS plaques, populated with (103)Pd, (125)I and (131)Cs sources. Ellipsoidal tumors were contoured for each plaque size and MATLAB programming was developed to generate tumor dose distributions for all possible ring weighting and radionuclide permutations for a given plaque size and source strength resolution, assuming a 75 Gy apical prescription dose. These dose distributions were analyzed for conformity and homogeneity and compared to reference dose distributions from uniformly-loaded (125)I plaques. The most conformal and homogeneous dose distributions were reproduced within a reference eye environment to assess organ-at-risk (OAR) doses in the Pinnacle(3) treatment planning system (TPS). The gamma-index analysis method was used to quantitatively compare MC and TPS-generated dose distributions. Concentrating > 97% of the total source strength in a single or pair of central (103)Pd seeds produced the most conformal dose distributions, with tumor basal doses a factor of 2-3 higher and OAR doses a factor of 2-3 lower than those of corresponding uniformly-loaded (125)I plaques. Concentrating 82-86% of the total source strength in peripherally-loaded (131)Cs seeds produced the most homogeneous dose distributions, with tumor basal doses 17-25% lower and OAR doses typically 20% higher than those of corresponding uniformly-loaded (125)I plaques. Gamma-index analysis found > 99% agreement between MC and TPS dose distributions. A method was developed to select intra-plaque ring radionuclide compositions and source strengths to deliver more conformal and homogeneous tumor dose distributions than

  17. Long-term Results of the UCSF-LBNL Randomized Trial: Charged Particle With Helium Ion Versus Iodine-125 Plaque Therapy for Choroidal and Ciliary Body Melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, Kavita K., E-mail: Kavita.mishra@ucsf.edu [Department of Radiation Oncology, University of California-San Francisco, San Francisco, California (United States); Quivey, Jeanne M.; Daftari, Inder K. [Department of Radiation Oncology, University of California-San Francisco, San Francisco, California (United States); Lawrence Berkeley National Laboratory, Berkeley, California (United States); Weinberg, Vivian [Department of Radiation Oncology, University of California-San Francisco, San Francisco, California (United States); Cole, Tia B. [The Tumori Foundation, San Francisco, California (United States); Patel, Kishan [Department of Radiation Oncology, University of California-San Francisco, San Francisco, California (United States); Castro, Joseph R.; Phillips, Theodore L. [Department of Radiation Oncology, University of California-San Francisco, San Francisco, California (United States); Lawrence Berkeley National Laboratory, Berkeley, California (United States); Char, Devron H. [The Tumori Foundation, San Francisco, California (United States); Department of Ophthalmology, University of California-San Francisco, San Francisco, California (United States); Department of Ophthalmology, Stanford University, Palo Alto, California (United States)

    2015-06-01

    Purpose: Relevant clinical data are needed given the increasing national interest in charged particle radiation therapy (CPT) programs. Here we report long-term outcomes from the only randomized, stratified trial comparing CPT with iodine-125 plaque therapy for choroidal and ciliary body melanoma. Methods and Materials: From 1985 to 1991, 184 patients met eligibility criteria and were randomized to receive particle (86 patients) or plaque therapy (98 patients). Patients were stratified by tumor diameter, thickness, distance to disc/fovea, anterior extension, and visual acuity. Tumors close to the optic disc were included. Local tumor control, as well as eye preservation, metastases due to melanoma, and survival were evaluated. Results: Median follow-up times for particle and plaque arm patients were 14.6 years and 12.3 years, respectively (P=.22), and for those alive at last follow-up, 18.5 and 16.5 years, respectively (P=.81). Local control (LC) for particle versus plaque treatment was 100% versus 84% at 5 years, and 98% versus 79% at 12 years, respectively (log rank: P=.0006). If patients with tumors close to the disc (<2 mm) were excluded, CPT still resulted in significantly improved LC: 100% versus 90% at 5 years and 98% versus 86% at 12 years, respectively (log rank: P=.048). Enucleation rate was lower after CPT: 11% versus 22% at 5 years and 17% versus 37% at 12 years, respectively (log rank: P=.01). Using Cox regression model, likelihood ratio test, treatment was the most important predictor of LC (P=.0002) and eye preservation (P=.01). CPT was a significant predictor of prolonged disease-free survival (log rank: P=.001). Conclusions: Particle therapy resulted in significantly improved local control, eye preservation, and disease-free survival as confirmed by long-term outcomes from the only randomized study available to date comparing radiation modalities in choroidal and ciliary body melanoma.

  18. Clinical application of permanent implantation of iodine 125 seeds for osseous metastases

    International Nuclear Information System (INIS)

    Li Jinxin; Zhang Qizhou; Li Guoliang

    2010-01-01

    Objective: To evaluate the clinical efficacy of permanent implantation of iodine 125 seeds in the treatment of osseous metastases. Methods: Radioactive iodine 125 seeds were implanted permanently in 32 lesions of 25 patients with osseous metastases of different origins. The ostalgia-relieving degree and the imaging alterations of the osseous metastasis lesions were observed. Results: The effective pain-relieving rate was 92% caused by permanent implantation of iodine 125 seeds. Of al 1 the patients, 15 patients achieved complete response, 8 patients obtained partial response (PR), and 2 patients had no change. The pain grade was decreased significantly after the treatment (P 125 I seeds has a definite effect on tumor metastasis and caused minimal damage and few complications. It is worthy of popularization in clinic. (authors)

  19. Quality asurance of iodinated (125 I) human fibrinogen

    International Nuclear Information System (INIS)

    Vines, E.J.

    1980-05-01

    The radiopharmaceutical iodinated ( 125 I) human fibrinogen is currently used for the detection of deep vein thrombosis in the legs, a fairly common post-surgical complication. A comprehensive quality assurance programme for ( 125 I) - human fibrinogen has been determined for routine use at the Australian Radiation Laboratory, with adaptions necessary for hospital quality control testing

  20. Health-Related Quality of Life up to Six Years After 125I Brachytherapy for Early-Stage Prostate Cancer

    International Nuclear Information System (INIS)

    Roeloffzen, Ellen M.A.; Lips, Irene M.; Gellekom, Marion P.R. van; Roermund, Joep van; Frank, Steven J.; Battermann, Jan J.; Vulpen, Marco van

    2010-01-01

    Purpose: Health-related quality of life (HRQOL) after prostate brachytherapy has been extensively described in published reports but hardly any long-term data are available. The aim of the present study was to prospectively assess long-term HRQOL 6 years after 125 I prostate brachytherapy. Methods and Materials: A total of 127 patients treated with 125 I brachytherapy for early-stage prostate cancer between December 2000 and June 2003 completed a HRQOL questionnaire at five time-points: before treatment and 1 month, 6 months, 1 year, and 6 years after treatment. The questionnaire included the RAND-36 generic health survey, the cancer-specific European Organization for Research and Treatment of Cancer core questionnaire (EORTCQLQ-C30), and the tumor-specific EORTC prostate cancer module (EORTC-PR25). A change in a score of ≥10 points was considered clinically relevant. Results: Overall, the HRQOL at 6 years after 125 I prostate brachytherapy did not significantly differ from baseline. Although a statistically significant deterioration in HRQOL at 6 years was seen for urinary symptoms, bowel symptoms, pain, physical functioning, and sexual activity (p 125 I prostate brachytherapy. HRQOL scores returned to approximately baseline values at 1 year and remained stable up to 6 years after treatment. 125 I prostate brachytherapy did not adversely affect patients' long-term HRQOL.

  1. Methodology of quality control for brachytherapy {sup 125}I seeds

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo S.; Zeituni, Carlos A.; Manzoli, Jose E.; Rostelato, Maria Elisa C.M. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: esmoura@ipen.br

    2007-07-01

    This paper presents the methodology of quality control of {sup 125}I seeds used for brachytherapy. The {sup 125}I seeds are millimeter titanium capsules widely used in permanent implants of prostate cancer, allowing a high dose within the tumour and a low dose on the surrounding tissues, with very low harm to the other tissues. Besides, with this procedure, the patients have a low impotence rate and a small incidence of urinary incontinence. To meet the medical standards, an efficient quality control is necessary, showing values with the minimum uncertainness possible, concerning the seeds dimensions and their respective activities. The medical needles are used to insert the seeds inside the prostate. The needles used in brachytherapy have an internal diameter of 1.0 mm, so it is necessary {sup 125}I seeds with an external maximum diameter of 0.85 mm. For the seeds and the spacer positioning on the planning sheet, the seeds must have a length between 4.5 and 5.0 mm. The activities must not vary more than 5% in each batch of {sup 125}I seeds. For this methodology, we used two ionization chamber detectors and one caliper. In this paper, the methodology using one control batch with 75 seeds manufactured by GE Health care Ltd is presented. (author)

  2. Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom.

    Science.gov (United States)

    Lesperance, Marielle; Inglis-Whalen, M; Thomson, R M

    2014-02-01

    To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with(125)I, (103)Pd, or (131)Cs seeds, and to investigate doses to ocular structures. An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom and our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20-30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%-10% and 13%-14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%-17% and 29%-34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up to 16%. In the full eye model

  3. Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom

    International Nuclear Information System (INIS)

    Lesperance, Marielle; Inglis-Whalen, M.; Thomson, R. M.

    2014-01-01

    Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with 125 I, 103 Pd, or 131 Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom and our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up

  4. Iodine-125 implants for carcinoma of the prostate

    International Nuclear Information System (INIS)

    Peschel, R.E.; Fogel, T.D.; Kacinski, B.M.; Kelly, K.; Mate, T.P.

    1985-01-01

    One hundred-thirteen patients underwent Iodine-125 prostate implant and lymphadenectomy at Yale-New Haven Hospital from 1974 through 1980. The distribution by clinical stage was: 7 Stage A2, 86 Stage B, and 20 Stage C patients. Ninety-four patients had a negative lymphadenectomy and 19 patients (17%) had metastatic disease in the pelvic lymph nodes (N+). The actuarial 5-year survival for all 113 patients was 87%. Local tumor control was 85% for all Stage B patients and 75% for all Stage C patients. Only 10 patients (9%) have developed long-term gastrointestinal or genitourinary complications following their implant. Iodine-125 implant appears to be a reasonable alternate form of therapy in highly selected groups of patients with carcinoma of the prostate

  5. Brachytherapy with cobalt plaques in the conservative treatment of intraocular tumors. The Brazilian experience

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Trippe, N.; Novaes, P.E.; Ferrigno, R.; Fogarolli, R.C.; Maia, M.A.C.; Salvajoli, J.V.; Baraldi, H.E.; Chojniak, M.M.; Erwene, C.M.

    1996-01-01

    Purpose/Objective: To show the retrospective results of intraocular tumors, including uveal melanomas and retinoblastomas treated by exclusive brachytherapy with cobalt plaques. The goal was to keep the vision function with not compromising the chance of cure. Materials and Methods: From December 1989 to December 1993, 76 cases of intraocular tumors, being 56 adult patients with uveal melanomas and 20 children with retinoblastoma, were treated with exclusive intraocular brachytherapy through cobalt plaques. The prescribed dose was 40 Gy, calculated at the apex of the lesion for retinoblastomas and 100 Gy for melanomas. The selection criteria included those introcular lesions with diameter until 15 mm. Results: With the minimum follow up of 24 months, of the 56 patients with uveal melanomas, 41 (73,3%) had their vision preserved with no evidence of disease, while 15 (26,4%) had local failure and were underwent to enucleation. With the medium follow up of 27 months, of the 20 patients with retinoblastoma, 17 (85,5%) had their vision preserved with no evidence of disease, while 3 (15%) had local failure and were underwent to enucleation. All patients are alive with no evidence of systemic disease. Conclusion: When well indicated, the conservative treatment of intraocular tumors with brachytherapy is a good alternative to enucleation and must be done by a multidisciplinary and well trained medical team

  6. Enzymatic iodination of salivary proteins by the 125I-lactoperoxidase system

    International Nuclear Information System (INIS)

    Tenovuo, J.; Sarimo, S.S.

    1977-01-01

    Purified milk lactoperoxidase and endogenous human salivary peroxidase were used to label the proteins of whole mouth saliva with [ 125 I]iodide. The proteins were then analyzed by isoelectric focusing or they were subjected to one-dimensional polyacrylamide gel electrophoresis at pH 8.4. The radioactivity of the resolved protein fractions was determined. There were three to four major and four to five minor areas of radioactivity which were carried together with more or less distinctive fractions. Amylase and albumin were shown to be the most effective in binding [ 125 I]iodide. No significant differences were observed in the iodination patterns of salivary proteins iodinated in the presence of endogenous saliva peroxidase and those iodinated in the presence of added milk lactoperoxidase. Hydrogen peroxide was necessary for iodination to take place. The significance of iodoproteins and the role of salivary peroxidases in the nonthyroidal metabolism of iodine are discussed. (author)

  7. Computed tomographic-guided iodine-125 interstitial implants for malignant thoracic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Qiming [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); The Department of Radiology, Second Affiliated Hospital of Fujian Medical University, 34 Zhongshan Bei Road, Quanzhou 362000 (China); Chen, Jin; Chen, Qunlin [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); Lai, Qingquan; Cai, Siqing [The Department of Radiology, Second Affiliated Hospital of Fujian Medical University, 34 Zhongshan Bei Road, Quanzhou 362000 (China); Luo, Kaidong [The Department of Radiology, Longyan Hosptial of Traditional Chinese Medical, 59 Longteng Middle Road, Longyan 364000 (China); Lin, Zhengyu, E-mail: linsinlan@yahoo.com.cn [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China)

    2013-11-01

    Purpose: To evaluate the feasibility and efficacy of percutaneous interstitial brachytherapy using iodine-125 ({sup 125}I) radioactive seeds under computed tomographic (CT) guidance for malignant thoracic tumors. Materials and methods: Forty-one patients (34 males, 7 females; 18–90 years; mean, 63.7 years) with 77 lesions (3 in the mediastinum, 7 in the chest wall, 67 in the lung) underwent percutaneous interstitial implantation of {sup 125}I radioactive seeds under CT guidance. A treatment planning system (TPS) was employed to calculate the number and distribution of seeds preoperatively. An 18-G needle was inserted into the lesions under CT guidance and send the seeds according to TPS. Two patients with mediastinal lesions undergoing seed implantation received an artificial pneumothorax. One patient with lung carcinoma adjacent to the anterior mediastinum underwent seed implantation through the sternum. Follow-up CT was done every 2 months postoperatively. Results: The procedure was successful in all patients. No major procedure-associated death occurred. The mean duration of follow-up was 19.4 ± 1.3 months (3–49 months). A complete response (CR) was seen in 49 lesions (63.6%), partial response (PR) in 9 lesions (11.7%), stable disease (SD) in 12 lesions (12.8%), and progressive disease (PD) in 7 lesions (7.4%). The overall response rate (CR + PR) was 75.3%; the local control rate (CR + PR + SD) was 90.9%. The 1-, 2- and 3-year progression-free rates for local tumors were 91%, 88% and 88%, respectively. The 1-, 2- and 3-year survival rates were 87%, 74% and 68%, respectively. Conclusion: Implantation of CT-guided {sup 125}I seeds is feasible and effective for patients with malignant thoracic tumors.

  8. Novel high resolution 125I brachytherapy source dosimetry using Ge-doped optical fibres

    International Nuclear Information System (INIS)

    Issa, Fatma; Hugtenburg, Richard P.; Nisbet, Andrew; Bradley, David A.

    2013-01-01

    The steep dose gradients close to brachytherapy sources limit the ability to obtain accurate measurements of dose. Here we use a novel high spatial resolution dosimeter to measure dose around a 125 I source and compare against simulations. Ge-doped optical fibres, used as thermoluminescent dosimeters, offer sub-mm spatial resolution, linear response from 10 cGy to >1 kGy and dose-rate independence. For a 125 I brachytherapy seed in a PMMA phantom, doses were obtained for source-dosimeter separations from 0.1 cm up to several cm, supported by EGSnrc/DOSRZznrc Monte Carlo simulations and treatment planning system data. The measurements agree with simulations to within 2.3%±0.3% along the transverse and perpendicular axes and within 3.0%±0.5% for measurements investigating anisotropy in angular dose distribution. Measured and Veriseed™ brachytherapy treatment planning system (TPS) values agreed to within 2.7%±0.5%. Ge-doped optical fibre dosimeters allow detailed dose mapping around brachytherapy sources, not least in situations of high dose gradient. - Highlights: • We evaluate fall-off in dose for distances from an 125 I source of 1 mm to 60 mm. • The TL of optical fibres accommodate high dose gradients and doses that reduce by a factor of 10 3 across the range of separations. • We verify measured values using DOSRZnrc Monte Carlo code simulations and the Variseed™ Treatment Planning System. • Measured radial and angular dose are obtained with ≤3% uncertainty

  9. Enzymatic labelling of. gamma. -globulin and insulin with iodine-125

    Energy Technology Data Exchange (ETDEWEB)

    Lucka, B; Russin, K [Institute of Nuclear Physics, Krakow (Poland)

    1979-01-01

    The parameters of enzymatic labelling of proteins with iodine 125 were examined. The manner and sequence of reagent addition, the effects of reagent concentration, reaction time and total Na/sup 125/I activity on the labelling yield were determined.

  10. External beam radiation therapy and a low-dose-rate brachytherapy boost without or with androgen deprivation therapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Strom, Tobin J.; Hutchinson, Sean Z.; Shrinath, Kushagra; Cruz, Alex A.; Figura, Nicholas B.; Nethers, Kevin; Biagioli, Matthew C.; Fernandez, Daniel C.; Heysek, Randy V.; Wilder, Richard B., E-mail: richard.wilder@moffitt.org [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States)

    2014-07-15

    Purpose: To assess outcomes with external beam radiation therapy (EBRT) and a low-dose-rate (LDR) brachytherapy boost without or with androgen deprivation therapy (ADT) for prostate cancer. Materials and Methods: From January 2001 through August 2011, 120 intermediate-risk or high-risk prostate cancer patients were treated with EBRT to a total dose of 4,500 cGy in 25 daily fractions and a palladium-103 LDR brachytherapy boost of 10,000 cGy (n = 90) or an iodine-125 LDR brachytherapy boost of 11,000 cGy (n = 30). ADT, consisting of a gonadotropin-releasing hormone agonist ± an anti-androgen, was administered to 29/92 (32%) intermediate-risk patients for a median duration of 4 months and 26/28 (93%) high-risk patients for a median duration of 28 months. Results: Median follow-up was 5.2 years (range, 1.1-12.8 years). There was no statistically-significant difference in biochemical disease-free survival (bDFS), distant metastasis-free survival (DMFS), or overall survival (OS) without or with ADT. Also, there was no statistically-significant difference in bDFS, DMFS, or OS with a palladium-103 vs. an iodine-125 LDR brachytherapy boost. Conclusions: There was no statistically-significant difference in outcomes with the addition of ADT, though the power of the current study was limited. The Radiation Therapy Oncology Group 0815 and 0924 phase III trials, which have accrual targets of more than 1,500 men, will help to clarify the role ADT in locally-advanced prostate cancer patients treated with EBRT and a brachytherapy boost. Palladium-103 and iodine-125 provide similar bDFS, DMFS, and OS. (author)

  11. Influence of 125I seed interstitial brachytherapy on recovery of facial nerve function

    International Nuclear Information System (INIS)

    Song Tieli; Zheng Lei; Zhang Jie; Cai Zhigang; Yang Zhaohui; Yu Guangyan; Zhang Jianguo

    2010-01-01

    Objective: To study the influence of 125 I seed interstitial brachytherapy in parotid region on the recovery of facial nerve function. Methods: A total of the data of 21 patients with primary parotid carcinoma were treated with resection and 125 I interstitial brachytherapy. All the patients had no facial palsy before operation and the prescribed dose was 60 Gy. During 4 years of follow-up, the House-Brackmann grading scales and ENoG were used to evaluate the function of facial nerve. According to the modified regional House-Brackmann grading scales, the facial nerve branches of patients in affected side were divided into normal and abnormal groups, and were compared with those in contra-lateral side. Results: Post-operation facial palsy occurred in all the patients, but the facial palsy recovered within 6 months. The latency time differences between affected side and contralateral side were statistically significant in abnormal group from 1 week to 6 months after treatment (t=2.362, P=0.028), and were also different in normal group 1 week after treatment (t=2.522, P=0.027). Conclusions: 125 I interstitital brachytherapy has no influence on recovery of facial nerve function after tumor resection and no delayed facial nerve damage. (authors)

  12. Implication for QOL after I-125 brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Teishima, Jun; Yasumoto, Hiroaki; Inoue, Syogo; Masumoto, Hiroshi; Hasegawa, Yasuhisa; Matsubara, Akio

    2009-01-01

    The aim of this study is to evaluate the quality of life (QOL) of patients following prostate brachytherapy. Between July 2004 and May 2008, 139 patients underwent I-125 permanent brachytherapy. Among those patients, 69 who were followed up for more than one year using the Expanded Prostate Index Composite (EPIC), Japanese version v1 TM , were enrolled in this study. Urinary summary scores became worse temporarily at 1 month after the end of treatment, but then recovered gradually to the level before treatment. Sexual summary scores before treatment were 42.2±16.3. They became worse temporarily at 1 month after treatment but then recovered gradually in patients whose sexual summary scores were more than 40. Urinary morbidity scores after prostate brachytherapy were not so severe and recovered within a short period. Further long-term observation is thought to be required in the future. Sexual function scores of patients before treatment in the present study were lower compared with those recorded in previous studies. (author)

  13. Exposure of treating physician to radiation during prostate brachytherapy using iodine-125 seeds. Dose measurements on both hands with thermoluminescence dosimeters

    International Nuclear Information System (INIS)

    Schiefer, Hans; Seelentag, Wolf; Plasswilm, Ludwig; Ries, Gerhard; Toggenburg, Friedrich von; Lenggenhager, Cornelius; Schmid, Hans-Peter; Leippold, Thomas; Engeler, Daniel; Prikler, Ladislav; Krusche, Bernd; Roth, Jakob

    2009-01-01

    Background and purpose: only sparse reports have been made about radiation exposure of the treating physician during prostate seed implantation. Therefore, thermoluminescence dosimeter (TLD) measurements on the index fingers and the backs of both hands were conducted. Material and methods: stranded iodine-125 seeds with a mean apparent activity of 27.4 MBq per seed were used. During application, the treating physician manipulated the loaded needle with the index fingers, partially under fluoroscopic control. Four physicians with varying experience treated 24 patients. The radiation exposure was determined with TLD-100 chips attached to the index fingertips and the backs of hands. Radiation exposure was correlated with the physician's experience. Results: the average brachytherapy duration by the most experienced physician was 19.2 min (standard deviation σ = 1.2 min; novices: 34.8 min [σ = 10.2 min]). The mean activity was 1,703 MBq (σ = 123 MBq), applied with 16.3 needles (σ = 2.5 needles; novices: 1,469 MBq [σ = 229 MBq]; 16.8 needles [σ = 2.3 needles ]). The exposure of the finger of the ''active hand'' and the back of the hand amounted to 1.31 mSv (σ = 0.54 mSv) and 0.61 mSv (σ = 0.23 mSv), respectively (novices: 2.07 mSv [σ = 0.86 mSv] and 1.05 mSv [σ = 0.53 mSv]). Conclusion: if no other radiation exposure needs to be considered, an experienced physician can perform about 400 applications per year without exceeding the limit of 500 mSv/year; for novices, the corresponding figure is about 200. (orig.)

  14. Radiotherapy and brachytherapy

    International Nuclear Information System (INIS)

    2007-02-01

    This presentation first defines the radiotherapy and brachytherapy techniques, indicates the used ionizing radiations (electromagnetic and particles), describes the mechanisms and processes of action of ionizing radiations: they can be physical by photon-matter interactions (Compton effect and photoelectric effect) or due to electron-matter interactions (excitation, ionization), physical-chemical by direct or indirect action (DNA damage), cellular (mitotic or apoptotic death), tissue (sane and tumorous tissues and differential effect). It discusses the biological efficiency of these treatments which depends on different parameters: intrinsic radio-sensitivity, time (session fractioning and organisation in time), oxygen, radiation quality, cellular cycle, dose rate, temperature. It presents the different types of radiotherapy: external radiotherapy (general sequence, delineation, dosimetry, protection of critical organs, treatment session, quality control, monitoring consultation) and briefly presents some specific techniques (total body irradiation, total cutaneous electron therapy, pre-operation radiotherapy, radio-surgery, hadron-therapy). It proposes an overview of the main indications for this treatment: brain tumours, upper aero digestive tract tumours, bronchial tumours, oesophagus, stomach and pancreas tumours, breast tumours, cervix cancer, rectum tumour, and so on, and indicates the possible associated treatments. The next part addresses brachytherapy. It presents the principles and comments the differences with radiotherapy. It indicates the used radio-elements (Caesium 137, Iridium 192, Iodine 125), describes the implementation techniques (plastic tubes, use of iodine 125, intracavitary and endo-luminal radiation therapy). It proposes an overview of the different treated tumours (skin, breast, prostates, bronchial, oesophagus, ENT) and indicates possible early and late secondary effects for different organs

  15. Focal salvage iodine-125 brachytherapy for prostate cancer recurrences after primary radiotherapy: A retrospective study regarding toxicity, biochemical outcome and quality of life

    International Nuclear Information System (INIS)

    Peters, Max; Maenhout, Metha; Voort van Zyp, Jochem R.N. van der; Moerland, Marinus A.; Moman, Maaike R.; Steuten, Lotte M.G.; Deursen, Marijke J.H. van; Vulpen, Marco van

    2014-01-01

    Purpose: Whole-gland salvage for recurrent prostate cancer (PCa) shows high failure and toxicity rates. Early and adequate localization of recurrences enables focal salvage, thereby potentially improving functional outcomes, while maintaining cancer control. Materials and methods: Retrospective analysis yielded 20 focal salvage I125 brachytherapy patients for locally recurrent PCa after primary radiotherapy. Tumor was defined by multiparametric MRI and correspondence with transrectal biopsies. Dose data were obtained intra-operatively. The tumor was prescribed ⩾144 Gy. Toxicity was scored by the Common Terminology Criteria for Adverse Events version 4 (CTCAE-4). Biochemical failure (BF) was defined using the Phoenix criteria (PSA-nadir + 2.0 ng/ml). Quality of life (QoL) was measured by SF-36 Health Survey and European Organization of Research and Treatment of Cancer (EORTC) C30+3 and PR25 questionnaires. Results: With a median follow-up of 36 months (range 10–45), six patients experienced BF, of which three had no initial response. Grade 3 genitourinary (GU) toxicity occurred in one patient (a urethral stricture). The five previously potent patients retained erectile function. QoL remained decreased with regard to urinary symptoms. Conclusion: Focal salvage I125 brachytherapy showed one grade 3 GU toxicity in the 20 treated patients. Biochemical response and QoL were acceptable

  16. Iodine 125 prostate brachytherapy: prognostic factors for long-term urinary, digestive and sexual toxicities

    International Nuclear Information System (INIS)

    Doyen, J.; Mohammed Ali, A.; Ginot, A.; Ferre, M.; Castelli, J.; Hannoun-Levi, J.M.; Chamorey, E.; Mohammed Ali, A.; Quintens, H.; Amiel, J.

    2009-01-01

    Purpose For patients with good urinary function and presenting with a low risk prostate cancer, prostate brachytherapy using iodine implants represents one of the techniques of reference. This retrospective analysis investigates urinary (U), digestive (D) and sexual (S) toxicities and their prognostic factors of duration. Material and methods From August 2000 to November 2007, 176 patients presenting with prostate adenocarcinoma underwent interstitial brachytherapy. Urinary, digestive and sexual toxicities were classified according to Common toxicities criteria for adverse events, version 3.0 (C.T.C.A.E. V 3.0). For each toxicity (U, D, S), the number of complications U (dysuria, nicturia), D (proctitis, diarrhea) and S (sexual dysfunction, loss of libido) was listed and analyzed according to criteria related to the patient, implant, dosimetric data and characteristics of the toxicity. Prognostic factors identified in univariate analysis (U.V.A.) (Log Rank) were further analyzed in multivariate analysis (M.V.A.) (Cox model). Results With a median follow-up of 26 months (1-87), 147 patients (83.5 %) presented urinary toxicities. Among them, 29.5 % (86 patients) and 2.4 % (seven patients) presented grade 2 and 3 U toxicity respectively. In U.V.A., urinary grade toxicity greater than or equal to 2 (p = 0.037), the presence of initial U symptoms (p = 0.027) and more than two urinary toxicities (p 0.00032) were recognized as prognostic factors. The number of U toxicities was the only prognostic factor in M.V.A. (p = 0.04). D toxicity accounted for 40.6 % (71 patients). Among them, 3 % (six patients) were grade 2. None were grade 3. Two factors were identified as prognostic factors either in U.V.A. and M.V.A.: the number of D toxicities greater than or equal to 2 (univariate analysis: p = 0,00129, multivariate analysis: p = 0,002) and age less than or equal to 65 years (univariate analysis: p = 0,004, multivariate analysis: p 0,007). Eighty-three patients (47

  17. Dosimetric studies, spectrometric, radiographic, metallographic of a new argentinean seed of 125 I used in brachytherapy

    International Nuclear Information System (INIS)

    Pirchio, R.; Saravi, M.; Banchik, D.; Munoz, C.

    2006-01-01

    A new source of 125 I model Braquibac TM has been developed in Argentina for applications in interstitial brachytherapy. The AAPM Task Group 43 (TG-43) recommends that dosimetric characteristics of new sources of brachytherapy of Iodine-125 have been theoretically and experimentally determined before its clinical use. The objectives outlined in this work were the study of the design of the new seed, the calculation of dosimetric parameters and the photons spectra analysis. Its were carried out radiographic and metallographic studies to determine the physical characteristics of the source. For the realization of the dosimetric calculations it was used the Monte Carlo code MCNP5. Values of the radial dose function, g(r), of the constant of dose rate, Λ, of the function of anisotropy of two dimensions, F(r, θ), of the factor and constant of anisotropy its were obtained simulating the source in water according to the recommended methodology in TG-43. The constant of dose rate is similar to 0,880 ± 0,080 c Gy h -1 U -1 . The kerma in air rate of reference, S K , was calculated as 1,036 c Gy cm 2 h -1 mCi -1 simulating the seed in dry air. Its were carried out spectrometric studies using a semiconductor planar detector of HPGe (high purity germanium). Photons spectra showed characteristic x-rays of 125 I with energies of 27,20 keV, 27,47 keV, 31 keV and 31,70 keV gamma photons of 35,5 keV, and x-ray fluorescent coming from the silver nucleus of 22,10 keV, 24,94 keV and 25,45 keV. The angular dependence of the intensity of photons around the seed and in air it was analyzed with the planar detector. This was carried out to study the anisotropy in the photons flow due to variation in the thickness of the titanium wall and of the welding, movements of the silver tube inside the source and deposition of the radioactive material on the silver tube. (Author)

  18. Evolution of different reaction methods resulting in the formation of AgI125 for use in brachytherapy sources

    International Nuclear Information System (INIS)

    Souza, C.D.; Peleias Jr, F.S.; Rostelato, M.E.C.M.; Zeituni, C.A.; Benega, M.A.G.; Tiezzi, R.; Mattos, F.R.; Rodrigues, B.T.; Oliveira, T.B.; Feher, A.; Moura, J.A.; Costa, O.L.

    2014-01-01

    Prostate cancer represents about 10% of all cases of cancer in the world. Brachytherapy has been extensively used in the early and intermediate stages of the illness. The radiotherapy method reduces the damage probability to surrounding healthy tissues. The present study compares several deposition methods of iodine-125 on silver substrate (seed core), in order to choose the most suitable one to be implemented at IPEN. Four methods were selected: method 1 (assay based on electrodeposition) which presented efficiency of 65.16%; method 2 (assay based on chemical reactions, developed by David Kubiatowicz) which presented efficiency of 70.80%; method 3 (chemical reaction based on the methodology developed by Dr. Maria Elisa Rostelato) which presented efficiency of 55.80%; new method developed by IPEN with 90.5% efficiency. Based on the results, the new method is the suggested one to be implemented. (authors)

  19. Dosimetry and treatment planning of Occu-Prosta 125I seeds for intraocular lesions

    International Nuclear Information System (INIS)

    Chaudhari, Suresh; Deshpande, Sudesh; Anand, Vivek; De, Sandeep; Kannan, V.; Saxena, Sanjay; Dash, A.; Basu, Mahua; Samant, Preetam

    2008-01-01

    Intraocular malignant lesions are frequently encountered in clinical practice. Plaque brachytherapy represents an effective means of treatment for intraocular lesions. Recently Radiopharmaceutical Division, BARC, Mumbai, has indigenously fabricated reasonable-cost 125 I sources. Here we are presenting the preliminary experience of dosimetry of sources, configuration of treatment planning system (TPS) and quality assurance (QA) for eye plaque therapy with Occu-Prosta 125 I seeds, treated in our hospital, for a patient with ocular lesions. 125 I seeds were calibrated using well-type chamber. BrachyVision TPS was configured with Monte Carlo computed radial dose functions and anisotropy functions for 125 I sources. Dose calculated by TPS at different points in central axis and off axis was compared with manually calculated dose. Eye plaque was fabricated of 17 karat pure gold, locally. The seeds were arranged in an outer ring near the edge of the plaque and in concentric rings throughout the plaque. The sources were manually digitized on the TPS, and dose distribution was calculated in three dimensions. Measured activity using cross-calibrated well-type chamber was within ± 10% of the activity specified by the supplier. Difference in TPS-calculated dose and manually calculated dose was within 5%. Treatment time calculated by TPS was in concordance with published data for similar plaque arrangement. (author)

  20. Radiation protection data sheets for the use of iodine 125 in unsealed sources

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This radiation protection data sheet is intended for supervisors and staff in the different medical, hospital, pharmaceutical, university and industrial laboratories and departments where Iodine 125 is handled, and also for all those involved in risk prevention in this field. It provides essential data on radiation protection measures during the use of Iodine 125 in unsealed sources: physical characteristics, risk assessment, administrative procedures, recommendations, regulations and bibliography

  1. Ejaculatory Function After Permanent 125I Prostate Brachytherapy for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Huyghe, Eric; Delannes, Martine; Wagner, Fabien M.; Delaunay, Boris; Nohra, Joe; Thoulouzan, Matthieu; Shut-Yee, J. Yeung; Plante, Pierre; Soulie, Michel; Thonneau, Patrick; Bachaud, Jean Marc

    2009-01-01

    Purpose: Ejaculatory function is an underreported aspect of male sexuality in men treated for prostate cancer. We conducted the first detailed analysis of ejaculatory function in patients treated with permanent 125 I prostate brachytherapy for localized prostate cancer. Patients and Methods: Of 270 sexually active men with localized prostate cancer treated with permanent 125 I prostate brachytherapy, 241 (89%), with a mean age of 65 years (range, 43-80), responded to a mailed questionnaire derived from the Male Sexual Health Questionnaire regarding ejaculatory function. Five aspects of ejaculatory function were examined: frequency, volume, dry ejaculation, pleasure, and pain. Results: Of the 241 sexually active men, 81.3% had conserved ejaculatory function after prostate brachytherapy; however, the number of patients with rare/absent ejaculatory function was double the pretreatment number (p < .0001). The latter finding was correlated with age (p < .001) and the preimplant International Index of Erectile Function score (p < .001). However, 84.9% of patients with maintained ejaculatory function after implantation reported a reduced volume of ejaculate compared with 26.9% before (p < .001), with dry ejaculation accounting for 18.7% of these cases. After treatment, 30.3% of the patients experienced painful ejaculation compared with 12.9% before (p = .0001), and this was associated with a greater number of implanted needles (p = .021) and the existence of painful ejaculation before implantation (p < .0001). After implantation, 10% of patients who continued to be sexually active experienced no orgasm compared with only 1% before treatment. in addition, more patients experienced late/difficult or weak orgasms (p = .001). Conclusion: Most men treated with brachytherapy have conserved ejaculatory function after prostate brachytherapy. However, most of these men experience a reduction in volume and a deterioration in orgasm.

  2. Synkavit and its direct labelling with iodine-125, as a potential anti-cancer drug

    International Nuclear Information System (INIS)

    Unak, T.; Unak, P.

    1993-01-01

    The compound known as ''synkavit'' is a diphosphate derivative of vitamin K 3 (menadion), which is capable of being selectively accumulated in certain tumour cells, and covalently bonded to DNA producing considerable DNA damage. On the other hand, iodine-125 nuclide incorporated into the nucleus of living cells causes extreme radiotoxic effects. Consequently, synkavit can be used as a specific carrier of iodine-125 into the nucleus of tumour cells. Thus, its iodo-derivatives have become interesting agents on the potential application of iodine-125 in cancer therapy. 6-Iodo-synkavit is a unique iodo-derivative described in the literature. In addition, its synthesis and radioiodination is still problematic, and consequently the results obtained using 6-iodo-synkavit labelled with iodine-125 remains in question. For this reason, the synthesis of 6-iodo-synkavit was examined in this study. It is finally determined that a mixture of different iodo-isomers of synkavit has been produced rather than its specific 6-iodo-isomer, when the synthetic sequence was begun with the direct sulfonation of 2-methyl-naphthalene. On the other hand, it is also determined that synkavit can directly be radioiodinated using different iodination techniques, and iodogen especially can be successfully used as an oxidative agent. (Author)

  3. Occupational exposure in prostate permanent implants with I-125 seeds

    Energy Technology Data Exchange (ETDEWEB)

    Fdez Garcia, J.; Luna, V.; Sancho, J. M. g.; Martinez, J.; Galiano, P. S.; Jimenez, I.; Prada, P.; Juan, G.; Vivanco, J.

    2002-07-01

    Prostate brachytherapy is one of the techniques increasing faster in the environment of the radiotherapy and will probably go on increasing in the future. There are two forms in their use; by means of remote afterloading high dose rate (HDR) with Ir-192 radioactive sources or by means of permanent implant by manual/automatic afterloading of low dose rate (LDR) with seeds of I-125 or Pd-103. Iodine-125 has a half life of 59.4 days and it decays by electron capture with emissions of characteristic photons and electrons. The electrons are absorbed by the titanium wall of the I-125 seed. The principal photon emissions are 27.4 and 31.4 keV X-rays and a 35.5 keV gamma ray. Besides 22.1 and 25.2 keV fluorescent X-rays are also emitted resulting from interactions of the iodine-125 photons with the silver rod. The resulting average photon energy is approximately 27.4 keV. (Author)

  4. Efficacy of 2.5 percent and 1.25 percent Povidone-Iodine Solution for Prophylaxis of Ophthalmia Neonatorum

    International Nuclear Information System (INIS)

    Khan, F. A.; Hussain, M. A.; Niazi, S. P. K.; Haq, Z. U.; Akhtar, N.

    2016-01-01

    Objective: To determine the efficacy of 2.5 percentage and 1.25 percentage Povidone-Iodine solution for Ophthalmia neonatorum prophylaxis. Study Design: Interventional study. Place and Duration of Study: Eye Department, Combined Military Hospital, Sargodha, from May to November 2014. Methodology: A total of 200 eyes of 100 newborn babies were enrolled and divided into two groups of 100 right eyes and 100 left eyes. A conjunctival swab for bacterial culture was taken within 30 minutes after delivery. A single drop of 2.5 percentage Povidone-Iodine was then placed in the right eye while in the left eye a single drop of 1.25 percentage Povidone-Iodine was placed. Thirty minutes after placing Povidone-Iodine, a conjunctival swab was again taken. A bacterial suspension was prepared from each swab in determining bacterial counts. The bacterial suspension was inoculated on yeast extract agar and the number of colony forming units were counted. At each culture, the number of colony forming units before and after instillation of 2.5 percentage Povidone-Iodine and 1.25 percentage Povidone-Iodine were compared. Wilcoxon's signed rank test was used for statistical analysis. Results: The 2.5 percentage Povidone-Iodine solution caused a statistically significant decrease in the number of colony forming units (p=0.001). Similarly, the 1.25 percentage Povidone-Iodine solution also reduced the number of colony forming units to a statistically significant level (p=0.001). Conclusion: The 1.25 percentage concentration of Povidone-Iodine is as effective as the 2.5 percentage concentration of Povidone-Iodine in reducing the number of colony forming units in healthy conjunctivae of newborns. (author)

  5. [Orgasm after curietherapy with permanent iodine-125 radioimplants for localized prostate cancer].

    Science.gov (United States)

    Delaunay, B; Delannes, M; Salloum, A; Delavierre, D; Wagner, F; Jonca, F; Thoulouzan, M; Plante, P; Bachaud, J-M; Soulie, M; Huyghe, E

    2011-12-01

    Orgasm is a domain of male sexuality that remains underreported in literature. Our aim was to realize the first detailed analysis of orgasm in patients treated by 125 I permanent prostate brachytherapy for localized prostate cancer. In a series of 270 sexually active men treated by prostate brachytherapy (125I permanent implantation), 241 (89%), mean age of 65 (43-80), participated in a mailed survey about sexual function after a mean time of 36 months (9-70). Erectile and ejaculatory functions and orgasm were explored using a mailed questionnaire. Two questions focused on orgasm. The first was about quality of orgasm (fast/intense/late, difficult/weak/absent) and the second about the presence of painful orgasm and its frequency (always/sometimes/often). After prostate brachytherapy, 81.3% of sexually active men conserved ejaculation and 90% orgasm. There was a significant deterioration of the quality of orgasm (P=0.0001). More than 50% of the patients had an altered orgasm (weak, difficult, absent) after brachytherapy, vs 16% before implantation (P=0.001). Men with a diminished ejaculation volume often had a weak/difficult orgasm (P=0.007). Neoadjuvant hormonal therapy did not seem to impact the quality of orgasm or the frequency of painful ejaculation. Patients who had an IIEF-5 score higher than 12 had frequently intense orgasm (26.7% vs 2.7%; Porgasm after treatment. However, most of the patients described a deterioration of the quality of orgasm. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  6. Iodine 125 seed migration after prostate brachytherapy: a study of 170 patients

    International Nuclear Information System (INIS)

    Chauveinc, L.; Osseili, A.; Rosenwald, J.C.; Cosset, J.M.; Flam, T.; Thiounn, N.; Savignoni, A.

    2004-01-01

    Purpose. To study the number of migrating seeds, the anatomical site of migration and possible predictive parameters of migration, after prostate cancer brachytherapy using a loose-seed (I125) implantation technique. Patients and methods. The charts of the 170 patients consecutively treated by the Institut Curie/Hospital Cochin/Hospital Necker Group between September 1, 2001 and August 31, 2002, were analysed. All seeds having migrated to the lungs and seen on the chest X-ray systematically performed at 2 months, have been recorded, as well as the seeds lost by the urines (after sieving) or in the sperm (condom). Results. Among 12,179 implanted seeds, 44 were found to have migrated (0.36%). Most of the migrating seeds (32/44; 73%), were found in the lungs. Overall, one or several seed migrations were observed in 35 patients (21% of the total number of patients in this series). In the majority of cases (77< r i. only one seed migrated. A significant relationship (P = 0.04) vs as found between the number of migrating seeds and the number of implanted ones (or with the prostate volume, but those two parameters were closely linked in our series). More specifically, a significant relationship (P = 0.02) could be demonstrated between the number of seeds implanted at the periphery of the prostate and the number of seeds migrating to the lungs. Conclusion. The percentage of migrating seeds observed in this series is low. actually one of the lowest found in the literature when using the loose-seed technique. There was no clinical consequences and the loss of-usually only one seed is very unlikely to alter the quality of the dose distribution. However, the predominance of pulmonary migrations in our series led us to slightly modify our implantation technique. We now try to avoid too 'peripheral' seed implantations, due to the risk of migration towards the peri-prostatic veins, and subsequently to the lungs. (author)

  7. SU-F-T-659: Nanoparticle-Aided Eye Plaque Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chin, J [University of Masschusetts-Lowell, Lowell, Massachusetts (United States); Ngwa, W [Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: Eye plaque brachytherapy is one of the approaches for radiotherapy treatment for ocular cancers: retinoblastoma and choroidal melanoma. This study, investigates the potential benefits of using gold nanoparticles to enhance therapeutic efficacy during eye plaque brachytherapy. Methods: The EYE PHYSICS Inc. Plaque Simulator program distributed by IsoAid, LLC, Port Richey, Florida was used. It is based on the superposition of dose contributions from individual seeds following the TG–43 formalism. Dose enhancement factor (DEF) values for feasible nanoparticle concentrations from previous studies was used to investigate the benefit of using nanoparticles to enhance dose to tumour or reduce dose to healthy tissue. The dose enhancement factor (DEF) represents the ratio of the dose deposited in tumour with nanoparticles divided by dose deposited in the tumour without nanoparticles. The investigation was done for I–125 and Pd–103 typical sources employed for eye plaque brachytherapy. The prescription dose used is 85 Gy. Results: Lower dose enhancement values were obtained for Pd–103. With DEF of 2 due to gold nanoparticles, critical structure doses reduce by a factor of 2. Optic disc dose is 6.69 Gy and 4.571 Gy, opposite retina dose is 4.064 and 2.484 Gy, lens dose is 12.66 Gy and 9.870 Gy, and fovea dose is 9.85 Gy and 7.275 Gy. With DEF of 3 due to gold nanoparticles, critical structure doses reduce by a factor of 3. Optic disc dose is 4.352 Gy and 2.975 Gy, opposite retina dose is 2.644 Gy and 1.618 Gy, lens dose is 8.322 Gy and 6.427 Gy, and fovea dose is 4.815 Gy and 4.737 Gy. Conclusion: The results of this research predict that using gold nanoparticles will lead to major sparing of dose to critical structures. The finding provides more impetus for the development of nanoparticle–aided brachytherapy.

  8. SU-F-T-659: Nanoparticle-Aided Eye Plaque Radiotherapy

    International Nuclear Information System (INIS)

    Chin, J; Ngwa, W

    2016-01-01

    Purpose: Eye plaque brachytherapy is one of the approaches for radiotherapy treatment for ocular cancers: retinoblastoma and choroidal melanoma. This study, investigates the potential benefits of using gold nanoparticles to enhance therapeutic efficacy during eye plaque brachytherapy. Methods: The EYE PHYSICS Inc. Plaque Simulator program distributed by IsoAid, LLC, Port Richey, Florida was used. It is based on the superposition of dose contributions from individual seeds following the TG–43 formalism. Dose enhancement factor (DEF) values for feasible nanoparticle concentrations from previous studies was used to investigate the benefit of using nanoparticles to enhance dose to tumour or reduce dose to healthy tissue. The dose enhancement factor (DEF) represents the ratio of the dose deposited in tumour with nanoparticles divided by dose deposited in the tumour without nanoparticles. The investigation was done for I–125 and Pd–103 typical sources employed for eye plaque brachytherapy. The prescription dose used is 85 Gy. Results: Lower dose enhancement values were obtained for Pd–103. With DEF of 2 due to gold nanoparticles, critical structure doses reduce by a factor of 2. Optic disc dose is 6.69 Gy and 4.571 Gy, opposite retina dose is 4.064 and 2.484 Gy, lens dose is 12.66 Gy and 9.870 Gy, and fovea dose is 9.85 Gy and 7.275 Gy. With DEF of 3 due to gold nanoparticles, critical structure doses reduce by a factor of 3. Optic disc dose is 4.352 Gy and 2.975 Gy, opposite retina dose is 2.644 Gy and 1.618 Gy, lens dose is 8.322 Gy and 6.427 Gy, and fovea dose is 4.815 Gy and 4.737 Gy. Conclusion: The results of this research predict that using gold nanoparticles will lead to major sparing of dose to critical structures. The finding provides more impetus for the development of nanoparticle–aided brachytherapy.

  9. Study and methodologies for fixing epoxy resin in radioactive sources used for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Bruna T.; Rostelato, Maria E.C.M.; Souza, Carla D.; Tozetti, Cíntia A.; Zeituni, Carlos A.; Nogueira, Beatriz R.; Silva, José T.; Júnior, Dib K.; Fernandes, Vagner; Souza, Raquel V.; Abreu, Rodrigo T., E-mail: bteigarodrigues@gmail.com, E-mail: elisaros@ipen.br, E-mail: carladdsouza@yahoo.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Universidade de São Paulo (USP), SP (Brazil)

    2017-07-01

    The World Health Organization (WHO) estimates that the number of new cancer cases worldwide will reach 15 million by 2020. The disease is already the second leading cause of death worldwide, being behind only cardiovascular disease. It is unquestionable that it is a public health problem, especially among developing countries. Prostate cancer is the most common among men, approximately 28.6%. The choice of type of treatment for prostate cancer should consider several factors such as: tumor size and extent, apparent aggressiveness (pathological characteristics), age, health. Among the methods applied, brachytherapy has been used in the initial and intermediate stages of the disease. Brachytherapy is a safe and effective treatment for localized prostate cancer. Brachytherapy is a form of radiotherapy in which radioactive seeds are placed in contact with or within the organ being treated. This technique allows a large dose of radiation to be released only on the target tumor that protects healthy surrounding tissues. Sources may have different shapes and sizes, but the one used for prostate cancer is usually 4.5 mm in length and 0.8 mm in diameter. About 80 to 120 seeds can be used per patient. Iodine-125 is the radioisotope most used in brachytherapy of the prostate, it emits 35,49keV X-rays in 100% of the decays, with average energy of 29 keV. The treatment of prostate cancer with permanent implantation of iodine-125 seeds has grown dramatically in the world in recent years. Most patients can return to normal life within three days with little or no pain. (author)

  10. Study and methodologies for fixing epoxy resin in radioactive sources used for brachytherapy

    International Nuclear Information System (INIS)

    Rodrigues, Bruna T.; Rostelato, Maria E.C.M.; Souza, Carla D.; Tozetti, Cíntia A.; Zeituni, Carlos A.; Nogueira, Beatriz R.; Silva, José T.; Júnior, Dib K.; Fernandes, Vagner; Souza, Raquel V.; Abreu, Rodrigo T.

    2017-01-01

    The World Health Organization (WHO) estimates that the number of new cancer cases worldwide will reach 15 million by 2020. The disease is already the second leading cause of death worldwide, being behind only cardiovascular disease. It is unquestionable that it is a public health problem, especially among developing countries. Prostate cancer is the most common among men, approximately 28.6%. The choice of type of treatment for prostate cancer should consider several factors such as: tumor size and extent, apparent aggressiveness (pathological characteristics), age, health. Among the methods applied, brachytherapy has been used in the initial and intermediate stages of the disease. Brachytherapy is a safe and effective treatment for localized prostate cancer. Brachytherapy is a form of radiotherapy in which radioactive seeds are placed in contact with or within the organ being treated. This technique allows a large dose of radiation to be released only on the target tumor that protects healthy surrounding tissues. Sources may have different shapes and sizes, but the one used for prostate cancer is usually 4.5 mm in length and 0.8 mm in diameter. About 80 to 120 seeds can be used per patient. Iodine-125 is the radioisotope most used in brachytherapy of the prostate, it emits 35,49keV X-rays in 100% of the decays, with average energy of 29 keV. The treatment of prostate cancer with permanent implantation of iodine-125 seeds has grown dramatically in the world in recent years. Most patients can return to normal life within three days with little or no pain. (author)

  11. Iodine-125 safety procedures in a biochemical laboratory

    International Nuclear Information System (INIS)

    1989-01-01

    Radioactive isotopes of iodine are of considerable importance in biochemical research and this 14 minute videotape is designed to give workers an introduction to the radiation safety aspects of their use. It deals with I-125, which is now generally used in preference to I-131, but the principles of safe working practice are the same for both isotopes. (author)

  12. 125I eye plaque dose distribution including penumbra characteristics.

    Science.gov (United States)

    de la Zerda, A; Chiu-Tsao, S T; Lin, J; Boulay, L L; Kanna, I; Kim, J H; Tsao, H S

    1996-03-01

    The two main purposes of this work are (1) to determine the penumbra characteristics for 125I eye plaque and the relative influence of the plaque and eye-air interface on the dose distribution, and (2) to initiate development of a treatment planning algorithm for clinical dose calculations. Dose was measured in a newly designed solid water eye phantom for an 125I (6711) seed at the center of a 20 mm COMS eye plaque using thermoluminescent dosimeter (TLD) "cubes" and "minichips" inside and outside the eye, in the longitudinal and transverse central planes. TLD cubes were used in most locations, except for short distances from the seed and in the penumbra region. In the presence of both the plaque and the eye-air interface, the dose along the central axis was found to be reduced by 10% at 1 cm and up to 20% at 2.5 cm, relative to the bulk homogeneous phantom case. In addition, the overall dose reduction was greater for larger off-axis coordinates at a given depth. The penumbra characteristics due to the lip collimation were quantified, particularly the dependence of penumbra center and width on depth. Only small differences were observed between the profiles in the transverse and longitudinal planes. In the bulk geometry (without the eye-air interface), the dose reduction due to the presence of the plaque alone was found to be 7% at a depth of 2.5 cm. The additional reduction of 13% observed, with the presence of eye-air interface (20% combined), can be attributed to the lack of backscattering from the air in front of the eye. The dose-reduction effect due to the anterior air interface alone became unnoticeable at a depth of 1.1 cm (1.5 cm from the eye-air interface). An analytic fit to measured data was developed for clinical dose calculations for a centrally loaded seed. The central axis values of the dose rates multiplied by distance squared, Dr2, were fitted with a double exponential function of depth. The off-axis profile of Dr2, at a given depth, was

  13. Urethral toxicity after LDR brachytherapy: experience in Japan.

    Science.gov (United States)

    Tanaka, Nobumichi; Asakawa, Isao; Hasegawa, Masatoshi; Fujimoto, Kiyohide

    2015-01-01

    Urinary toxicity is common after low-dose-rate (LDR) brachytherapy, and the resolution of urinary toxicity is a concern. In particular, urinary frequency is the most common adverse event among the urinary toxicities. We have previously reported that approximately 70% of patients experience urinary frequency during the first 6 months after seed implantation. Most urinary adverse events were classified as Grade 1, and Grade 2 or higher adverse events were rare. The incidence of urinary retention was approximately 2-4%. A high International Prostate Symptom Score before seed implantation was an independent predictor of acute urinary toxicity of Grade 2 or higher. Several previous reports from the United States also supported this trend. In Japan, LDR brachytherapy was legally approved in 2003. A nationwide prospective cohort study entitled Japanese Prostate Cancer Outcome Study of Permanent Iodine-125 Seed Implantation was initiated in July 2005. It is an important issue to limit urinary toxicities in patients who undergo LDR brachytherapy. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  14. Production of 125I from amorphous films of Si doped with 124Xe and evaluation of its potential use in brachytherapy

    International Nuclear Information System (INIS)

    Leal, Alexandre S.; Viana, Gustavo A.

    2015-01-01

    This work describes the simulation of a new material that can be used in the brachytherapy treatment. The material consists of xenon-incorporated amorphous silicon (Xe@a-Si). The irradiated 124 Xe atoms of the samples are converted into 125 Xe, according to the reaction: 124 Xe (n,γ) 125 Xe that, in turn, decays to the radioisotope 125 I. A set of simulations performed using the MCNP5 code, shows that, in principle, the material proposed can be used in the seed of brachytherapy in the clinical treatment. (author)

  15. Orgasm after prostate curietherapy with iodine 125 permanent implants for localized cancer of the prostate

    International Nuclear Information System (INIS)

    Delaunay, B.; Plante, P.; Huyghe, E.; Delannes, M.; Bachaud, J.-M.; Salloum, A.; Thoulouzan, M.; Soulie, M.; Delavierre, D.; Wagner, F.; Jonca, F.

    2011-01-01

    Orgasm is a domain of male sexuality that remains underreported in literature. Our aim was to realize the first detailed analysis of orgasm in patients treated by 125 I permanent prostate brachytherapy for localized prostate cancer. In a series of 270 sexually active men treated by prostate brachytherapy ( 125 I permanent implantation), 241 (89%), mean age of 65 (43 80), participated in a mailed survey about sexual function after a mean time of 36 months (9 70). Erectile and ejaculatory functions and orgasm were explored using a mailed questionnaire. Two questions focused on orgasm. The first was about quality of orgasm (fast/intense/late, difficult/weak/absent) and the second about the presence of painful orgasm and its frequency (always/sometimes/often). After prostate brachytherapy, 81.3% of sexually active men conserved ejaculation and 90% orgasm. There was a significant deterioration of the quality of orgasm (P ≡ 0.0001). More than 50% of the patients had an altered orgasm (weak, difficult, absent) after brachytherapy, vs 16% before implantation (P ≡ 0.001). Men with a diminished ejaculation volume often had a weak/difficult orgasm (P ≡ 0.007). Neoadjuvant hormonal therapy did not seem to impact the quality of orgasm or the frequency of painful ejaculation. Patients who had an IIEF-5 score higher than 12 had frequently intense orgasm (26.7% vs 2.7%; P < 0.001) after brachytherapy. Sixty patients (30.3%) experienced often/sometimes painful ejaculation 12.9% (n ≡ 31) before implantation (P ≡ 0.0001). Most of the patients treated by prostate brachytherapy conserved orgasm after treatment. However, most of the patients described a deterioration of the quality of orgasm. (authors)

  16. Brachytherapy Application With In Situ Dose Painting Administered by Gold Nanoparticle Eluters

    International Nuclear Information System (INIS)

    Sinha, Neeharika; Cifter, Gizem; Sajo, Erno; Kumar, Rajiv; Sridhar, Srinivas; Nguyen, Paul L.; Cormack, Robert A.; Makrigiorgos, G. Mike; Ngwa, Wilfred

    2015-01-01

    Purpose: Recent studies show promise that administering gold nanoparticles (GNP) to tumor cells during brachytherapy could significantly enhance radiation damage to the tumor. A new strategy proposed for sustained administration of the GNP in prostate tumors is to load them into routinely used brachytherapy spacers for customizable in situ release after implantation. This in silico study investigated the intratumor biodistribution and corresponding dose enhancement over time due to GNP released from such GNP-loaded brachytherapy spacers (GBS). Method and Materials: An experimentally determined intratumoral diffusion coefficient (D) for 10-nm nanoparticles was used to estimate D for other sizes by using the Stokes-Einstein equation. GNP concentration profiles, obtained using D, were then used to calculate the corresponding dose enhancement factor (DEF) for each tumor voxel, using dose painting-by-numbers approach, for times relevant to the considered brachytherapy sources' lifetimes. The investigation was carried out as a function of GNP size for the clinically applicable low-dose-rate brachytherapy sources iodine-125 (I-125), palladium-103 (Pd-103), and cesium-131 (Cs-131). Results: Results showed that dose enhancement to tumor voxels and subvolumes during brachytherapy can be customized by varying the size of GNP released or eluted from the GBS. For example, using a concentration of 7 mg/g GNP, significant DEF (>20%) could be achieved 5 mm from a GBS after 5, 12, 25, 46, 72, 120, and 195 days, respectively, for GNP sizes of 2, 5, 10, 20, 30, and 50 nm and for 80 nm when treating with I-125. Conclusions: Analyses showed that using Cs-131 provides the highest dose enhancement to tumor voxels. However, given its relatively longer half-life, I-125 presents the most flexibility for customizing the dose enhancement as a function of GNP size. These findings provide a useful reference for further work toward development of potential new brachytherapy application

  17. Brachytherapy Application With In Situ Dose Painting Administered by Gold Nanoparticle Eluters

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, Neeharika [Department of Sciences, Wentworth Institute of Technology, Boston, Massachusetts (United States); Cifter, Gizem [Department of Physics and Applied Physics, University of Massachusetts, Lowell, Massachusetts (United States); Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (United States); Sajo, Erno [Department of Physics and Applied Physics, University of Massachusetts, Lowell, Massachusetts (United States); Kumar, Rajiv; Sridhar, Srinivas [Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (United States); Electronic Materials Research Institute and Department of Physics, Northeastern University, Boston, Massachusetts (United States); Nguyen, Paul L.; Cormack, Robert A.; Makrigiorgos, G. Mike [Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (United States); Ngwa, Wilfred, E-mail: wngwa@lroc.harvard.edu [Department of Physics and Applied Physics, University of Massachusetts, Lowell, Massachusetts (United States); Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (United States)

    2015-02-01

    Purpose: Recent studies show promise that administering gold nanoparticles (GNP) to tumor cells during brachytherapy could significantly enhance radiation damage to the tumor. A new strategy proposed for sustained administration of the GNP in prostate tumors is to load them into routinely used brachytherapy spacers for customizable in situ release after implantation. This in silico study investigated the intratumor biodistribution and corresponding dose enhancement over time due to GNP released from such GNP-loaded brachytherapy spacers (GBS). Method and Materials: An experimentally determined intratumoral diffusion coefficient (D) for 10-nm nanoparticles was used to estimate D for other sizes by using the Stokes-Einstein equation. GNP concentration profiles, obtained using D, were then used to calculate the corresponding dose enhancement factor (DEF) for each tumor voxel, using dose painting-by-numbers approach, for times relevant to the considered brachytherapy sources' lifetimes. The investigation was carried out as a function of GNP size for the clinically applicable low-dose-rate brachytherapy sources iodine-125 (I-125), palladium-103 (Pd-103), and cesium-131 (Cs-131). Results: Results showed that dose enhancement to tumor voxels and subvolumes during brachytherapy can be customized by varying the size of GNP released or eluted from the GBS. For example, using a concentration of 7 mg/g GNP, significant DEF (>20%) could be achieved 5 mm from a GBS after 5, 12, 25, 46, 72, 120, and 195 days, respectively, for GNP sizes of 2, 5, 10, 20, 30, and 50 nm and for 80 nm when treating with I-125. Conclusions: Analyses showed that using Cs-131 provides the highest dose enhancement to tumor voxels. However, given its relatively longer half-life, I-125 presents the most flexibility for customizing the dose enhancement as a function of GNP size. These findings provide a useful reference for further work toward development of potential new brachytherapy application

  18. Study and development of methodology for radioactive iodine fixation in polymeric substrate for manufacturing sources used in brachytherapy; Estudo e desenvolvimento de metodologia para fixacao de iodo radioativo em substrato polimerico para confeccao de fontes utilizadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Bruna T.; Souza, Carla D.; Benega, Marcos A.G. and others, E-mail: bteigarodrigues@gmail.com, E-mail: carladdsouza@yahoo.com.br, E-mail: marcosagbenega@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes

    2014-07-01

    According global estimates of Globocan 2012 project of the International Agency for Research of Cancer, of the World Health Organization, there were 14,1 million new cases of cancer and a total of 8,2 million deaths from cancer. Also show that in 2030, the overall load will be 21,4 million new cases and 13,2 million cancer deaths. One of the prostate cancer therapy is brachytherapy, used in early and middle stages of the disease. It is made with the introduction of seeds with radioactive material within the tumor or in nearby regions, affecting the minimum surrounding tissues. The aim of this work is the study and developing the deposition of radioactive iodine on the polymeric substrate method, and an analysis relating the efficiency of the method to implementation in the laboratory of brachytherapy from IPEN. Iodine-125 is adsorbed on an epoxy resin solution. The objective of this study is to offer a new proposal for seeds. The results will give the data for the radiation protection and the procedures for radioactive waste management.

  19. Postenucleation orbits in retinoblastoma: treatment with 125I brachytherapy

    International Nuclear Information System (INIS)

    Stannard, Clare; Sealy, Ross; Hering, Egbert; Hough, Jan; Knowles, Ruth; Lecuona, Karin; Reddi, V. Bala

    2002-01-01

    Purpose: Children with retinoblastoma that extends into or through the choroid, sclera, or optic nerve are at risk of developing orbital disease, as well as metastases. Previously, these enucleated orbits were treated with external beam radiotherapy in addition to chemotherapy. 125 I brachytherapy for tumors in and around the eye was pioneered by Sealy in Cape Town, South Africa, in 1974. In 1983, he developed a technique to irradiate the contents of the orbit while limiting the dose to the bony orbit and eyelids. Methods and Materials: Six nylon tubes containing 125 I seeds were implanted through the eyelids around the periphery of the orbit. Each contained a metal gutter that screens the outer part of the seeds from the bony orbit. A seventh unscreened tube was placed in the center, and a metal disc with 125 I seeds on its posterior surface was secured beneath the eyelids. Between 1983 and 2000, 57 orbits were treated in 56 children with retinoblastoma. Thirty-six were treated prophylactically and 21, with tumor at the resection line of the nerve, extrascleral tumor, or metastases, were treated therapeutically. They received a median dose of 34 Gy in 70 h; 30 also received chemotherapy. Children with tumor at the resection line of the nerve also received treatment to the craniospinal axis. Results: The median follow-up of the 35 patients treated prophylactically was 35 months (range 0-187). Seven patients died, 6 of metastases, at a median of 10 months (range 4-29) after the implant. Eight of the 13 patients with microscopic extraocular tumor survived a median of 29 months (range 5-156). None of the 8 patients presenting with orbital tumor or metastases survived. No orbital recurrences developed in any of the patients. Cosmesis was considerably improved compared with previous forms of irradiation. Conclusion: Orbital brachytherapy is an effective method of irradiating the orbit to prevent recurrent tumor, the treatment time is short, and the cosmesis is much more

  20. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co.

    Science.gov (United States)

    Reed, J L; Rasmussen, B E; Davis, S D; Micka, J A; Culberson, W S; DeWerd, L A

    2014-12-01

    To determine the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters (TLD-100) for (125)I and (103)Pd brachytherapy sources relative to (60)Co. LiF:Mg,Ti TLDs were irradiated with low-energy brachytherapy sources and with a (60)Co teletherapy source. The brachytherapy sources measured were the Best 2301 (125)I seed, the OncoSeed 6711 (125)I seed, and the Best 2335 (103)Pd seed. The TLD light output per measured air-kerma strength was determined for the brachytherapy source irradiations, and the TLD light output per air kerma was determined for the (60)Co irradiations. Monte Carlo (MC) simulations were used to calculate the dose-to-TLD rate per air-kerma strength for the brachytherapy source irradiations and the dose to TLD per air kerma for the (60)Co irradiations. The measured and MC-calculated results for all irradiations were used to determine the TLD intrinsic energy dependence for (125)I and (103)Pd relative to (60)Co. The relative TLD intrinsic energy dependences (relative to (60)Co) and associated uncertainties (k = 1) were determined to be 0.883 ± 1.3%, 0.870 ± 1.4%, and 0.871 ± 1.5% for the Best 2301 seed, OncoSeed 6711 seed, and Best 2335 seed, respectively. The intrinsic energy dependence of TLD-100 is dependent on photon energy, exhibiting changes of 13%-15% for (125)I and (103)Pd sources relative to (60)Co. TLD measurements of absolute dose around (125)I and (103)Pd brachytherapy sources should explicitly account for the relative TLD intrinsic energy dependence in order to improve dosimetric accuracy.

  1. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co

    International Nuclear Information System (INIS)

    Reed, J. L.; Micka, J. A.; Culberson, W. S.; DeWerd, L. A.; Rasmussen, B. E.; Davis, S. D.

    2014-01-01

    Purpose: To determine the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters (TLD-100) for 125 I and 103 Pd brachytherapy sources relative to 60 Co. Methods: LiF:Mg,Ti TLDs were irradiated with low-energy brachytherapy sources and with a 60 Co teletherapy source. The brachytherapy sources measured were the Best 2301 125 I seed, the OncoSeed 6711 125 I seed, and the Best 2335 103 Pd seed. The TLD light output per measured air-kerma strength was determined for the brachytherapy source irradiations, and the TLD light output per air kerma was determined for the 60 Co irradiations. Monte Carlo (MC) simulations were used to calculate the dose-to-TLD rate per air-kerma strength for the brachytherapy source irradiations and the dose to TLD per air kerma for the 60 Co irradiations. The measured and MC-calculated results for all irradiations were used to determine the TLD intrinsic energy dependence for 125 I and 103 Pd relative to 60 Co. Results: The relative TLD intrinsic energy dependences (relative to 60 Co) and associated uncertainties (k = 1) were determined to be 0.883 ± 1.3%, 0.870 ± 1.4%, and 0.871 ± 1.5% for the Best 2301 seed, OncoSeed 6711 seed, and Best 2335 seed, respectively. Conclusions: The intrinsic energy dependence of TLD-100 is dependent on photon energy, exhibiting changes of 13%–15% for 125 I and 103 Pd sources relative to 60 Co. TLD measurements of absolute dose around 125 I and 103 Pd brachytherapy sources should explicitly account for the relative TLD intrinsic energy dependence in order to improve dosimetric accuracy

  2. Stereotactic iodine-125 brachytherapy for brain tumors: temporary versus permanent implantation

    Directory of Open Access Journals (Sweden)

    Ruge Maximilian I

    2012-06-01

    Full Text Available Abstract Stereotactic brachytherapy (SBT has been described in several publications as an effective, minimal invasive and safe highly focal treatment option in selected patients with well circumscribed brain tumors 40 cGy/h in combination with adjuvant external beam radiation and/or chemotherapy for the treatment of malignant gliomas and metastases resulted in increased rates of radiation induced adverse tissue changes requiring surgical intervention. Vice versa, such effects have been only minimally observed in numerous studies applying low dose rate (LDR regiments (3–8 cGy/h for low grade gliomas, metastases and other rare indications. Besides these observations, there are, however, no data available directly comparing the long term incidences of tissue changes after HDR and LDR and there is, furthermore, no evidence regarding a difference between temporary or permanent LDR implantation schemes. Thus, recommendations for effective and safe implantation schemes have to be investigated and compared in future studies.

  3. Acute exposure to Iodine-125: a case study

    Energy Technology Data Exchange (ETDEWEB)

    Kol, R; Canfi, A; Dukhan, N; Pelled, O; Brikner, D; Laichter, Y; Gold, B [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    Radioiodines I-125 and I-131 are extremely volatile even in the form of the relatively stable Iodine anion. This property renders frequent airborne contamination and sometimes accidental inhalation of the radioiodine by personnel heavily involved with it`s handling. In order to detect radioiodine contamination as early as possible, the laboratory and its surroundings are constantly air monitored, surfaces are monitored according to a predetermined regime and personnel is being checked upon completion of a job or upon leaving the laboratory. Follow-up, routine or in special occasions, is performed by health-physics personnel who reports to the radiation medicine department. We report here the measures and means used to monitor a case of an accidental inhalation of I-125 due to an externally contaminated NaI[I-125] commercial package. The monitoring of the contamination is described, the dose to the thyroid and the Committed Effective Dose Equivalent (CEDE) are reported, and the medical evaluation is presented (authors).

  4. Survival benefit of chemoembolization plus Iodine125 seed implantation in unresectable hepatitis B-related hepatocellular carcinoma with PVTT: a retrospective matched cohort study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Mingsheng; Wang, Haofan; Chen, Junwei; Bai, Mingjun; Wang, Long; Zhu, Kangshun; Jiang, Zaibo; Guan, Shouhai; Li, Zhengran; Qian, Jiesheng; Li, Mingan; Pang, Pengfei; Shan, Hong [Sun Yat-sen University, Department of Radiology, the Third Affiliated Hospital, Guangzhou (China); Sun Yat-Sen University, Department of Interventional Radiology, Ling-nan Hospital, Guangzhou (China); Sun Yat-sen University, Interventional Radiology Institute, Guangzhou (China); Lin, Qu [Sun Yat-sen University, Department of Oncology, the Third Affiliated Hospital, Guangzhou (China)

    2016-10-15

    To investigate the survival benefit of transarterial chemoembolization (TACE) plus Iodine125 seed implantation (TACE-Iodine125) in hepatitis B-related HCC patients with portal vein tumour thrombus (PVTT) and the underlying prognostic factors. A retrospective matched cohort study was performed on consecutive HCC patients with PVTT from January 2011 to June 2014. Seventy patients (TACE-Iodine125 group) who underwent TACE-Iodine125 were compared with a historical case-matched control group of 140 patients (TACE group) who received TACE alone. The survival of patients and the underlying prognostic factors were analysed. The median survival times of the TACE-Iodine125 and TACE groups were 11.0 and 7.5 months, respectively (p < 0.001). The survival probability at 12, 24, and 36 months was 50 %, 14.5 %, and 14.5 % vs. 25 %, 9 %, and 5 % in the TACE-Iodine125 and TACE groups, respectively (p < 0.001). The PVTT responders had better survival than the PVTT non-responders (p < 0.001). For the PVTT non-responders, there were no differences in the survival curves between the groups (p = 0.353). Multivariate analysis showed that type III PVTT (p < 0.001) and APS (p < 0.001) were independent predictors of poor prognosis. In contrast, the treatment modality of TACE-Iodine125 (p < 0.001) and PVTT response (p = 0.001) were favourable prognostic features. TACE combined with Iodine125 seed implantation may be a good choice for selected HB-HCC patients with PVTT. (orig.)

  5. SU-F-T-02: Estimation of Radiobiological Doses (BED and EQD2) of Single Fraction Electronic Brachytherapy That Equivalent to I-125 Eye Plaque: By Using Linear-Quadratic and Universal Survival Curve Models

    International Nuclear Information System (INIS)

    Kim, Y; Waldron, T; Pennington, E

    2016-01-01

    Purpose: To test the radiobiological impact of hypofractionated choroidal melanoma brachytherapy, we calculated single fraction equivalent doses (SFED) of the tumor that equivalent to 85 Gy of I125-BT for 20 patients. Corresponding organs-at-risks (OARs) doses were estimated. Methods: Twenty patients treated with I125-BT were retrospectively examined. The tumor SFED values were calculated from tumor BED using a conventional linear-quadratic (L-Q) model and an universal survival curve (USC). The opposite retina (α/β = 2.58), macula (2.58), optic disc (1.75), and lens (1.2) were examined. The % doses of OARs over tumor doses were assumed to be the same as for a single fraction delivery. The OAR SFED values were converted into BED and equivalent dose in 2 Gy fraction (EQD2) by using both L-Q and USC models, then compared to I125-BT. Results: The USC-based BED and EQD2 doses of the macula, optic disc, and the lens were on average 118 ± 46% (p 14 Gy). Conclusion: The estimated single fraction doses were feasible to be delivered within 1 hour using a high dose rate source such as electronic brachytherapy (eBT). However, the estimated OAR doses using eBT were 112 ∼ 118% higher than when using the I125-BT technique. Continued exploration of alternative dose rate or fractionation schedules should be followed.

  6. Spectroscopic output of {sup 125}I and {sup 103}Pd low dose rate brachytherapy sources

    Energy Technology Data Exchange (ETDEWEB)

    Usher-Moga, Jacqueline; Beach, Stephen M.; DeWerd, Larry A. [Department of Medical Physics, University of Wisconsin--Madison, Madison, Wisconsin 53705 (United States); Global Physics Solutions, St. Joseph, Michigan 49085 (United States); Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)

    2009-01-15

    The spectroscopic output of low dose rate (LDR) brachytherapy sources is dependent on the physical design and construction of the source. Characterization of the emitted photons from 12 {sup 125}I and 3 {sup 103}Pd LDR brachytherapy source models is presented. Photon spectra, both along the transverse bisector and at several polar angles, were measured in air with a high-purity reverse electrode germanium (REGe) detector. Measured spectra were corrected to in vacuo conditions via Monte Carlo and analytical methods. The tabulated and plotted spectroscopic data provide a more complete understanding of each source model's output characteristics than can be obtained with other measurement techniques. The variation in fluorescence yield of the {sup 125}I sources containing silver caused greater differences in the emitted spectra and average energies among these seed models than was observed for the {sup 103}Pd sources or the {sup 125}I sources that do not contain silver. Angular spectroscopic data further highlighted the effects of source construction unique to each model, as well as the asymmetric output of many seeds. These data demonstrate the need for the incorporation of such physically measured output characteristics in the Monte Carlo modeling process.

  7. An analysis of brachytherapy with computed tomography-guided permanent implantation of Iodine-125 seeds for recurrent nonkeratin nasopharyngeal carcinoma

    Directory of Open Access Journals (Sweden)

    Shen X

    2015-05-01

    Full Text Available Xinying Shen,1,2 Yong Li,2 Yanfang Zhang,2 Jian Kong,2 Yanhao Li1 1Department of Interventional Radiology, Nanfang Hospital, Southern Medical University, Guangzhou, 2Department of Interventional Radiology, Shenzhen People’s Hospital, The Second Clinical Medical College of Jinan University, Shenzhen, People’s Republic of China Background: 125I seed implantation is a new method in treatment of nasopharyngeal carcinoma (NPC, and it is worthwhile to evaluate its feasibility. In this study, we performed brachytherapy with computed tomography (CT-guided permanent implantation of 125I seeds in the treatment of patients with the recurrence of NPC.Methods: A total 30 patients (20 male and ten female at the median age of 55 (range 25–80 years were diagnosed with recurrent nonkeratin NPC, with a total 38 lesions and a short disease-free interval (median ~11 months after primary radiotherapy alone or combined with chemotherapy. Patients received CT scan, starting from 2 months after the treatment. Follow-up was conducted for ~2–38 months to observe the local control rate and overall survival rate. We also analyzed the possible correlation between survival periods and the status of recurrent tumors.Results: The local control rates at 6, 12, 24, 30, and 36 months after the procedure of 125I seed implantation were 86.8%, 73.7%, 26.3%, 15.8%, and 5.3%, respectively. The overall 1-, 2-, and 3-year survival rates were 80.0% (24/30, 30.0% (9/30, and 6.7% (2/30, respectively, with a median survival period of 18 months (17.6±8.6 months. Interestingly, the survival periods of the patients who had primary radiotherapy with or without chemotherapy were 15.8±7.9 and 24.3±7.9 months, respectively. Kaplan–Meier survival analysis demonstrated that χ2 (log rank was 7.555, with very significant difference (P<0.01. The survival periods of patients in tumor stages I, II, III, and IV were 25.4±8.7, 19.8±9.4, 16.1±4.5, and 12.8±7.8 months, respectively, with

  8. Dosimetric study of permanent prostate brachytherapy utilizing 131Cs, 125I and 103Pd seeds

    International Nuclear Information System (INIS)

    Yang Ruijie; Wang Junjie; Zhang Hongzhi

    2009-01-01

    Objective: To compare the dosimetric differences of permanent prostate brachytherapy utilizing 131 Cs, 125 I and 103 Pd seeds. Methods: Twenty-five patients with T 1 -T 2 c prostate cancer who had previously implanted with 125 I seeds were randomly selected in our study. The patients were re-planned with 131 Cs, 125 I and 103 Pd seeds by using the Prowess Brachytherapy 3.1 planning system to the prescription doses of 115 Gy, 145 Gy and 125 Gy, respectively. The seed strengths were 1.8 U,0.5 U and 1.8 U, respectively. The prostate, prostatic urethra and anterior wall of the rectum were contoured on trans-rectal ultrasound images. PTV was outlined based on the prostate volume with no margin applied. The attempted planning goals were that V 100 (the percentage volume of the prostate receiving at least 100% of the prescription doses)= 95%, D 90 (the minimum percentage dose covering 90% of the prostate volume) ≥100%, and prostatic urethra UD 10 (the maximum percentage dose receiving by 10% of the contoured urethra) ≤150%. For the plan comparison, we also computed prostate V 150 , prostatic urethra UV 120 , rectum RV 100 , and the number of implanted seeds and needles. The significance of the differences was tested using one way analysis of variance. Results: The average V 200 in the 103 Pd, 125 I and 131 Cs plans were 28.7%, 20.9% and 19.6% (F=42.50, P=0.000); the average V 150 were 51.9%, 42.1% and 39.4% (F=26.15, P=0.000); the average UV 120 were 26.9%, 29.5% and 23.8% (F=0.37, P=0.691); and the average rectum RV 100 were 0.31 cm 3 , 0.22 cm 3 and 0.19 cm 3 (F=0.43, P=0.652). For 103 Pd, 125 I and 131 Cs, the average number of implanted seeds per cm 3 prostate were 2.02, 2.01 and 1.87 (F=1.92, P=0.154), and the average number of needles were 33.6, 32.9 and 31.6 (F=0.26,P=0.772). Conclusions: Comparing to 125 I and 103 Pd seeds used in permanent prostate brachytherapy, 131 Cs seeds has better dose homogeneity, and possible better sparing of the urethra and rectum

  9. A study of Brachytherapy for Intraocular Tumor

    International Nuclear Information System (INIS)

    Ji, Kwang Soo; Yoo, Dae Hyun; Lee, Sung Goo; Kim, Jae Hu; Ji, Young Hun

    1996-01-01

    The eye enucleation or external-beam radiation therapy that has been commonly used for the treatment of intraocular tumor have demerits of visual loss and in deficiency of effective tumor dose. Recently, brachytherapy using the plaques containing radioisotope-now treatment method that decrease the demerits of the above mentioned treatment methods and increase the treatment effect-is introduced and performed in the countries, Our purpose of this research is to design suitable shape of plaque for the ophthalmic brachytherapy, and to measure absorbed doses of Ir-192 ophthalmic plaque and thereby calculate the exact radiation dose of tumor and it's adjacent normal tissue. In order to brachytherapy for intraocular tumor, 1. to determine the eye model and selected suitable radioisotope 2. to design the suitable shape of plaque 3. to measure transmission factor and dose distribution for custom made plaques 4. to compare with the these data and results of computer dose calculation models. The result were as followed. 1. Eye model was determined as a 25 mm diameter sphere, Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15 mm, 17 mm and 20 mm in diameter, and 1.5 mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5 mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ±10% and distance deviations are within 0.4 mm Maximum error is -11.3% and 0.8 mm, respectively. As a result of it, we can treat the intraocular tumor more effectively by using custom made gold plaque and Ir-192

  10. Palladium-103 plaque radiotherapy for choroidal melanoma: an 11-year study

    International Nuclear Information System (INIS)

    Finger, Paul T.; Berson, Anthony; Ng, Tracy; Szechter, Andrzej

    2002-01-01

    Purpose: To describe 11 years of experience with 103 Pd ophthalmic plaque brachytherapy for intraocular melanoma. Methods and Materials: Since 1990, 152 patients have been diagnosed with uveal melanoma, found to be negative for metastatic disease, and treated with 103 Pd radioactive plaque radiotherapy. This study presents the first 100 patients treated with 103 Pd and followed for ≥2 years. Plaques were sewn to the episclera to cover the base of the intraocular tumor. Treatment involved delivery of a mean apical radiation dose of 80.5 Gy during 5-7 days' continuous treatment. Patients were evaluated for local tumor control, visual acuity, radiation damage (retinopathy, optic neuropathy, cataract), and metastatic disease. Results: Patients in this series were followed for a mean of 4.6 years (55.4 months). 103 Pd seeds were found to be equivalent to 125 I with respect to plaque manufacture and ease of dosimetric calculations. We noted a local control rate of 96% and six secondary enucleations. Including the enucleated patients, the visual acuity evaluations revealed that 35% lost six or more lines of vision and 73% had vision of 20/200 or better. Conclusion: Long-term results now exist describing the use of 103 Pd plaque radiotherapy for uveal (iris, ciliary body, and choroidal) melanoma. Compared with the results from centers using 125 I, patients in this series experienced equivalent local control rates and better visual function

  11. {sup 125}I seed implant brachytherapy for the treatment of parotid gland cancers in children and adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, L.; Zhang, J.; Song, T.; Zhang, J.; Yu, G.; Zhang, Y. [Peking University School and Hospital of Stomatology, Beijing (China). Dept. of Oral and Maxillofacial Surgery

    2013-05-15

    Background and purpose: There is a lack of optimal treatment strategies for managing salivary gland cancers in children and adolescents. This study is aimed at assessing the effect of {sup 125}I seed implantation for the treatment of parotid cancers in children and adolescents. Patients and methods: A total of 12 patients younger than 16 years with parotid gland malignant tumors underwent {sup 125}I seed implant brachytherapy between October 2003 and November 2008. All patients were assessed after treatment and at the local tumor control appointments. Facial nerve function, maxillofacial development, and radioactive side-effects were assessed. Results: The follow-up period ranged from 41-104 months. One patient with T4b died of pulmonary metastasis. The other patients were alive during the follow-up period. There were no serious radiation-related complications. The treatment did not affect facial nerve function and dentofacial growth in any of the children. Conclusion: For parotid gland cancers in children, {sup 125}I seed implant brachytherapy may be an acceptable treatment without serious complications and with satisfactory short-term effects. (orig.)

  12. CT-guided {sup 125}I brachytherapy for mediastinal metastatic lymph nodes recurrence from esophageal carcinoma: Effectiveness and safety in 16 patients

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Fei, E-mail: gaof@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Li, Chuanxing, E-mail: licx@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Gu, Yangkui, E-mail: guyk@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Huang, Jinhua, E-mail: huangjh@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Wu, Peihong, E-mail: vivian-link@163.com [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China)

    2013-02-15

    Objectives: To retrospectively evaluate effectiveness and safety of CT-guided {sup 125}I brachytherapy in 16 patients with mediastinal metastatic lymph nodes recurrence from esophageal carcinoma. Materials and methods: Sixteen metastatic lymph nodes in 16 patients were percutaneously treated in 19 {sup 125}I brachytherapy sessions. Each metastatic lymph node was treated with computed tomographic (CT) guidance. Follow-up contrast material-enhanced CT or positron emission tomographic (PET) scans were reviewed and the treatment's effectiveness was evaluated. Results: Months are counted from the first time of {sup 125}I brachytherapy and the median duration of follow-up was 11 months (range, 5–16 months). The local control rates after 3, 6, 10 and 15 months were 75.0, 50.0, 42.9 and 33.3% respectively. At the time of writing, four patients are alive without evidence of recurrence at 16, 9, 16 and 9 months. The 4 patients presented good control of local tumor and no systemic recurrence, and survived throughout the follow-up period. The other 12 patients died of multiple hematogenous metastases 5–15 months after brachytherapy. A small amount of local hematoma occurred in 2 patients that involved applicator insertion through the lung. Two patients presented pneumothorax with pulmonary compression of 30 and 40% after the procedure and recovered after drainage. One patient had minor displacement of radioactive seeds. Severe complications such as massive bleeding and radiation pneumonitis did not occur. Conclusion: {sup 125}I radioactive seed implantation is effective and may be safely applied to mediastinal metastatic lymph nodes recurrence from esophageal carcinoma.

  13. Staff dose of hospitalization in the treatment of patients in ophthalmic brachytherapy with 125 I

    International Nuclear Information System (INIS)

    Terron Leon, J. A.; Gomez Palacios, M.; Moreno Reyes, J. C.; Perales Molina, A.

    2013-01-01

    The objective of this work, therefore, has been the evaluation of the dose levels which nursing staff can receive in care for ophthalmic brachytherapy patients treated with 125 I from measurements made on the same, evaluating, in an experimental way, job security following the PR rules laid down for these treatments. (Author)

  14. Radioiodinated benzimidazole derivatives as single photon emission computed tomography probes for imaging of {beta}-amyloid plaques in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Cui Mengchao [Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501 (Japan); Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875 (China); Ono, Masahiro, E-mail: ono@pharm.kyoto-u.ac.j [Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501 (Japan); Kimura, Hiroyuki; Kawashima, Hidekazu [Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501 (Japan); Liu Boli [Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875 (China); Saji, Hideo, E-mail: hsaji@pharm.kyoto-u.ac.j [Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501 (Japan)

    2011-04-15

    Five iodinated 2-phenyl-1H-benzo[d]imidazole derivatives were synthesized and evaluated as potential probes for {beta}-amyloid (A{beta}) plaques. One of the compounds, 4-(6-iodo-1H-benzo[d]imidazol-2-yl)-N,N-dimethylaniline (12), showed excellent affinity for A{beta}{sub 1-42} aggregates (K{sub i}=9.8 nM). Autoradiography with sections of postmortem Alzheimer's disease (AD) brain revealed that a radioiodinated probe [{sup 125}I]12, labeled A{beta} plaques selectively with low nonspecific binding. Biodistribution experiments with normal mice injected intravenously with [{sup 125}I]12 showed high uptake [4.14 percent injected dose per gram (% ID/g) at 2 min] into and rapid clearance (0.15% ID/g at 60 min) from the brain, which may bring about a good signal-to-noise ratio and therefore achieve highly sensitive detection of A{beta} plaques. In addition, [{sup 125}I]12 labeled amyloid plaques in vivo in an AD transgenic model. The preliminary results strongly suggest that [{sup 125}I]12 bears characteristics suitable for detecting amyloid plaques in vivo. When labeled with {sup 123}I, it may be a useful SPECT imaging agent for A{beta} plaques in the brain of living AD patients.

  15. Permanent 125I-seed prostate brachytherapy: early prostate specific antigen value as a predictor of PSA bounce occurrence

    Directory of Open Access Journals (Sweden)

    Mazeron Renaud

    2012-03-01

    Full Text Available Abstract Purpose To evaluate predictive factors for PSA bounce after 125I permanent seed prostate brachytherapy and identify criteria that distinguish between benign bounces and biochemical relapses. Materials and methods Men treated with exclusive permanent 125I seed brachytherapy from November 1999, with at least a 36 months follow-up were included. Bounce was defined as an increase ≥ 0.2 ng/ml above the nadir, followed by a spontaneous return to the nadir. Biochemical failure (BF was defined using the criteria of the Phoenix conference: nadir +2 ng/ml. Results 198 men were included. After a median follow-up of 63.9 months, 21 patients experienced a BF, and 35.9% had at least one bounce which occurred after a median period of 17 months after implantation (4-50. Bounce amplitude was 0.6 ng/ml (0.2-5.1, and duration was 13.6 months (4.0-44.9. In 12.5%, bounce magnitude exceeded the threshold defining BF. Age at the time of treatment and high PSA level assessed at 6 weeks were significantly correlated with bounce but not with BF. Bounce patients had a higher BF free survival than the others (100% versus 92%, p = 0,007. In case of PSA increase, PSA doubling time and velocity were not significantly different between bounce and BF patients. Bounces occurred significantly earlier than relapses and than nadir + 0.2 ng/ml in BF patients (17 vs 27.8 months, p Conclusion High PSA value assessed 6 weeks after brachytherapy and young age were significantly associated to a higher risk of bounces but not to BF. Long delays between brachytherapy and PSA increase are more indicative of BF.

  16. Dosimetric Calculations of a Radioactive Eye Plaque used in Management of Ocular Melanoma Using Monte Carlo Simulations

    Directory of Open Access Journals (Sweden)

    P Shokrani

    2009-10-01

    Full Text Available Introduction & Objective: Brachytherapy using I-125 radioactive seeds in removable episcleral plaques (EP is often used in treatment of ocular malignant melanoma. Some radioactive seeds are fixed in a gold bowl-shaped plaque. The plaque is sutured to the sclera surface corresponding to the base of the intraocular tumor, allowing for a localized radiation dose delivery to the tumor. Minimum target doses as high as 85Gy are directed at malignant tumor. The aim of this study was to develop a Monte Carlo simulation of an ocular plaque in order to calculate the resulting isodose distributions. Materials & Methods: The MCNP-4C Monte Carlo code is used to simulate the plan of an episcleral plaque treatment. A 20-mm Collaborative Ocular Melanoma Study (COMS plaque with 3, I-125 seed of model 6711 was used. Resulting dose distributions, including central axis dose and off-axis dose profiles, were calculated in a water phantom with 12mm radius. The calculated dose distributions were compared to the corresponding dose measured by Knuten et al., 2001. Results: Central axis dose calculations represent a rapid dose fall off, which is an important factor in selection of appropriate eye plaque for management of tumors with known dimension. Calculated off-axis dose profiles show decreased dose uniformity at distances close to the plaque. Increasing of distance from the plaque resulted in increasing of the dose uniformity. Conclusion: Monte Carlo simulation of eye plaques can be used as a useful tool in process of design, development and treatment planning of ocular radioactive plaques.

  17. Quantification of iodine in porous hydroxyapatite matrices for application as radioactive sources in brachytherapy

    Directory of Open Access Journals (Sweden)

    Kássio André Lacerda

    2007-07-01

    Full Text Available In this study, non-radioactive iodine was incorporated in two types of biodegradable hydroxyapatite-based porous matrices (HA and HACL through impregnation process from sodium iodine aqueous solutions with varying concentrations (0.5 and 1.0 mol/L . The results revealed that both systems presented a high capacity of incorporating iodine into their matrices. The quantity of incorporated iodine was measured through Neutron Activation Analysis (NAA. The porous ceramic matrices based on hydroxyapatite demonstrated a great potential for uses in low dose rate (LDR brachytherapy.Materiais cerâmicos porosos à base de compostos de fosfatos de cálcio (CFC vêm sendo estudados e desenvolvidos para várias aplicações biomédicas tais como implantes, sistemas para liberação de drogas e fontes radioativas para braquiterapia. Dois tipos de matrizes porosas biodegradáveis de hidroxiapatita (HA e HACL foram avaliadas em termos da capacidade de incorporação de iodo em suas estruturas. Resultados revelaram que as matrizes porosas a base de hidroxiapatita apresentaram alta capacidade de incorporar iodo em sua estrutura. A quantidade de iodo foi mensurada através da técnica de Análise por Ativação Nêutronica (AAN. As matrizes cerâmicas porosas à base de hidroxiapatita demostraram ter grande potencial para aplicação em braquiterapia de baixa taxa de dose (LDR - Low Dose Rate.

  18. Iodine-125 Chitosan-Vitamin C complex. Preparation, characterization and application

    Energy Technology Data Exchange (ETDEWEB)

    Elbarbary, Ahmed M. [National Center for Radiation Research and Technology, Cairo (Egypt). Polymer Chemistry Dept.; Shafik, H.M.; Ebeid, N.H.; Ayoub, S.M. [Atomic Energy Authority, Cairo (Egypt). Hot Lab. Center; Othman, Sameh H. [Atomic Energy Authority, Cairo (Egypt). Nuclear Research Center

    2015-07-01

    In heterogeneous conditions, water soluble Chitosan-Vitamin C Complex (CSVC) is successfully synthesized via the ionic interaction between γ-degraded CS and VC. Chitosan (CS) of low molecular weight (MW) is prepared using γ-irradiation method. The coupling of CS and vitamin C (VC) is carried out by the chemical treatment of VC with the γ-degraded CS. The formation of CSVC complex instead of physical mixture is confirmed by FT-IR and UV spectrometry. Characterization by transmission electron microscope (TEM) and dynamic light scattering (DLS) shows the formation of a nanostructure in 40 nm range. The preparation of labeled CSVC was performed using chloramines-T oxidation method. The labeling feasibility of CSVC nanostructure by Iodine-125 ({sup 125}I) is investigated. The optimized conditions of labeling are thought to be 50 μg of oxidizing agent, pH 3, and one minute reaction time. The Biodistribution activity of {sup 125}I radiolabeled CSVC nanostructure ({sup 125}I-CSVC) is examined on a group of different ascites tumor bearing mice. Calculation of the biodistribution percentages shows that the tumor, liver, and kidney are the targeting organs of {sup 125}I-CSVC nanostructure.

  19. Iodine-125 Chitosan-Vitamin C complex. Preparation, characterization and application

    International Nuclear Information System (INIS)

    Elbarbary, Ahmed M.; Shafik, H.M.; Ebeid, N.H.; Ayoub, S.M.; Othman, Sameh H.

    2015-01-01

    In heterogeneous conditions, water soluble Chitosan-Vitamin C Complex (CSVC) is successfully synthesized via the ionic interaction between γ-degraded CS and VC. Chitosan (CS) of low molecular weight (MW) is prepared using γ-irradiation method. The coupling of CS and vitamin C (VC) is carried out by the chemical treatment of VC with the γ-degraded CS. The formation of CSVC complex instead of physical mixture is confirmed by FT-IR and UV spectrometry. Characterization by transmission electron microscope (TEM) and dynamic light scattering (DLS) shows the formation of a nanostructure in 40 nm range. The preparation of labeled CSVC was performed using chloramines-T oxidation method. The labeling feasibility of CSVC nanostructure by Iodine-125 ( 125 I) is investigated. The optimized conditions of labeling are thought to be 50 μg of oxidizing agent, pH 3, and one minute reaction time. The Biodistribution activity of 125 I radiolabeled CSVC nanostructure ( 125 I-CSVC) is examined on a group of different ascites tumor bearing mice. Calculation of the biodistribution percentages shows that the tumor, liver, and kidney are the targeting organs of 125 I-CSVC nanostructure.

  20. DNA-PKcs Expression Is a Predictor of Biochemical Recurrence After Permanent Iodine 125 Interstitial Brachytherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Molina, Sarah; Guerif, Stéphane; Garcia, Alexandre; Debiais, Céline; Irani, Jacques; Fromont, Gaëlle

    2016-01-01

    Purpose: Predictive factors for biochemical recurrence (BCR) in localized prostate cancer (PCa) after brachytherapy are insufficient to date. Cellular radiosensitivity depends on DNA double-strand breaks, mainly repaired by the nonhomologous end-joining (NHEJ) system. We analyzed whether the expression of NHEJ proteins can predict BCR in patients treated by brachytherapy for localized PCa. Methods and Materials: From 983 PCa cases treated by brachytherapy between March 2000 and March 2012, 167 patients with available biopsy material suitable for in situ analysis were included in the study. The median follow-up time was 47 months. Twenty-nine patients experienced BCR. All slides were reviewed to reassess the Gleason score. Expression of the key NHEJ proteins DNA-PKcs, Ku70, and Ku80, and the proliferation marker Ki67, was studied by immunohistochemistry performed on tissue microarrays. Results: The Gleason scores after review (P=.06) tended to be associated with BCR when compared with the score initially reported (P=.74). Both the clinical stage (P=.02) and the pretreatment prostate-specific antigen level (P=.01) were associated with biochemical failure. Whereas the expression of Ku80 and Ki67 were not predictive of relapse, positive DNA-PKcs nuclear staining (P=.003) and higher Ku70 expression (P=.05) were associated with BCR. On multivariate analysis, among pretreatment variables, only DNA-PKcs (P=.03) and clinical stage (P=.02) remained predictive of recurrence. None of the patients without palpable PCa and negative DNA-PKcs expression experienced biochemical failure, compared with 32% of men with palpable and positive DNA-PKcs staining that recurred. Conclusions: Our results suggest that DNA-PKcs could be a predictive marker of BCR after brachytherapy, and this might be a useful tool for optimizing the choice of treatment in low-risk PCa patients.

  1. DNA-PKcs Expression Is a Predictor of Biochemical Recurrence After Permanent Iodine 125 Interstitial Brachytherapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Molina, Sarah [Department of Pathology, INSERM UMR1069, CHU/Université de Tours, Tours (France); Department of Radiation Oncology, CHU/Université de Poitiers, Poitiers (France); Guerif, Stéphane; Garcia, Alexandre [Department of Radiation Oncology, CHU/Université de Poitiers, Poitiers (France); Debiais, Céline [Department of Pathology, CHU/Université de Poitiers, Poitiers (France); Irani, Jacques [Department of Urology, CHU/Université de Poitiers, Poitiers (France); Fromont, Gaëlle, E-mail: gaelle.fromont-hankard@univ-tours.fr [Department of Pathology, INSERM UMR1069, CHU/Université de Tours, Tours (France)

    2016-07-01

    Purpose: Predictive factors for biochemical recurrence (BCR) in localized prostate cancer (PCa) after brachytherapy are insufficient to date. Cellular radiosensitivity depends on DNA double-strand breaks, mainly repaired by the nonhomologous end-joining (NHEJ) system. We analyzed whether the expression of NHEJ proteins can predict BCR in patients treated by brachytherapy for localized PCa. Methods and Materials: From 983 PCa cases treated by brachytherapy between March 2000 and March 2012, 167 patients with available biopsy material suitable for in situ analysis were included in the study. The median follow-up time was 47 months. Twenty-nine patients experienced BCR. All slides were reviewed to reassess the Gleason score. Expression of the key NHEJ proteins DNA-PKcs, Ku70, and Ku80, and the proliferation marker Ki67, was studied by immunohistochemistry performed on tissue microarrays. Results: The Gleason scores after review (P=.06) tended to be associated with BCR when compared with the score initially reported (P=.74). Both the clinical stage (P=.02) and the pretreatment prostate-specific antigen level (P=.01) were associated with biochemical failure. Whereas the expression of Ku80 and Ki67 were not predictive of relapse, positive DNA-PKcs nuclear staining (P=.003) and higher Ku70 expression (P=.05) were associated with BCR. On multivariate analysis, among pretreatment variables, only DNA-PKcs (P=.03) and clinical stage (P=.02) remained predictive of recurrence. None of the patients without palpable PCa and negative DNA-PKcs expression experienced biochemical failure, compared with 32% of men with palpable and positive DNA-PKcs staining that recurred. Conclusions: Our results suggest that DNA-PKcs could be a predictive marker of BCR after brachytherapy, and this might be a useful tool for optimizing the choice of treatment in low-risk PCa patients.

  2. Factors affecting radiation injury after interstitial brachytherapy for brain tumors

    International Nuclear Information System (INIS)

    Leibel, S.A.; Gutin, P.H.; Davis, R.L.

    1991-01-01

    The effects of brachytherapy on normal brain tissue are not easily delineated in the clinical setting because of the presence of concurrent radiation-induced changes in the coexistent brain tumor. Sequential morphologic studies performed after the implantation of radioactive sources into the brains of experimental animals have provided a better understanding of the character and magnitude of the structural changes produced by interstitial irradiation on normal brain tissue. Furthermore, the clinical experience accumulated thus far provides not only relevant information, but also some guidelines for future treatment policies. In this paper, the authors summarize the experimental findings and review the pathologic and clinical features of brain injury caused by interstitial brachytherapy. A number of studies in the older literature examined the effects of radioisotopes such as radium-226 (38--43), radon-22 (44--46), gold-198 (29,47--50), tantalum-182 (29,51,52) yttrium-9- (50,53,54), and cobalt-60 (29,50,55). This review is restricted to low- and high-activity encapsulated iodine-125 ( 125 I) and iridium-192 ( 192 Ir), the isotopes that are most commonly used in current clinical practice

  3. Preparation of high-quality iodine-125-labeled pituitary luteinizing hormone for radioimmunoassay

    International Nuclear Information System (INIS)

    Pinto, H.; Wajchenberg, B.L.; Higa, O.Z.; Toledo e Souza, I.T. de; Werner, R.S.; Pieroni, R.R.

    1974-01-01

    High quality pituitary luteinizing hormone labeled with 125 I was obtained after separating out the more heavily iodinated fractions, through starch gel electrophoresis, using the cathodal component (fraction 1) which was further purified on Sephadex G-100, with the obtention of an almost pure 125 I-LH preparation, presenting excellent immunoreactivity and low levels of damage on incubation in plasma. The quality control of the steps of the technique was done with plasma-coated talc (200 mg) which compared favorably, as far indicating undamaged labeled LH, with the more time-consuming chromatoelectrophoresis

  4. Recurrent primary lumbar vertebra chondrosarcoma: Marginal resection and Iodine-125 seed therapy

    Directory of Open Access Journals (Sweden)

    Chunpeng Ren

    2014-01-01

    Full Text Available Chondrosarcomas are uncommon in the spinal column. En bloc excisions with wide margins are of critical importance but not always feasible in spine. We report the outcome in a case of recurrent lumbar vertebral chondrosarcoma treated with marginal resection and iodine-125 seeds placed in the resected tumor bed.

  5. SU-F-T-02: Estimation of Radiobiological Doses (BED and EQD2) of Single Fraction Electronic Brachytherapy That Equivalent to I-125 Eye Plaque: By Using Linear-Quadratic and Universal Survival Curve Models

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y; Waldron, T; Pennington, E [University Of Iowa, College of Medicine, Iowa City, IA (United States)

    2016-06-15

    Purpose: To test the radiobiological impact of hypofractionated choroidal melanoma brachytherapy, we calculated single fraction equivalent doses (SFED) of the tumor that equivalent to 85 Gy of I125-BT for 20 patients. Corresponding organs-at-risks (OARs) doses were estimated. Methods: Twenty patients treated with I125-BT were retrospectively examined. The tumor SFED values were calculated from tumor BED using a conventional linear-quadratic (L-Q) model and an universal survival curve (USC). The opposite retina (α/β = 2.58), macula (2.58), optic disc (1.75), and lens (1.2) were examined. The % doses of OARs over tumor doses were assumed to be the same as for a single fraction delivery. The OAR SFED values were converted into BED and equivalent dose in 2 Gy fraction (EQD2) by using both L-Q and USC models, then compared to I125-BT. Results: The USC-based BED and EQD2 doses of the macula, optic disc, and the lens were on average 118 ± 46% (p < 0.0527), 126 ± 43% (p < 0.0354), and 112 ± 32% (p < 0.0265) higher than those of I125-BT, respectively. The BED and EQD2 doses of the opposite retina were 52 ± 9% lower than I125-BT. The tumor SFED values were 25.2 ± 3.3 Gy and 29.1 ± 2.5 Gy when using USC and LQ models which can be delivered within 1 hour. All BED and EQD2 values using L-Q model were significantly larger when compared to the USC model (p < 0.0274) due to its large single fraction size (> 14 Gy). Conclusion: The estimated single fraction doses were feasible to be delivered within 1 hour using a high dose rate source such as electronic brachytherapy (eBT). However, the estimated OAR doses using eBT were 112 ∼ 118% higher than when using the I125-BT technique. Continued exploration of alternative dose rate or fractionation schedules should be followed.

  6. Investigations on a cortisol-iodine-125-radioimmunoassay test system

    International Nuclear Information System (INIS)

    Hegerl, U.

    1981-01-01

    On the basis of a cortisol-iodine-125-RIA test system the reliability criteria were detected. Additionally, the so-called normal values of the cortisol daily rhythm were determined in a test group with normal metabolism. Moreover, in an other examination control values for the ACTH stimulation were registered and in addition the reproducability of this test was investigated. The results of the examinations and investigations confirm the necessity of taking precision and normal values determined in the own laboratory - as basis for the interpretation of radiochemical substrate analyses. (orig./MG) [de

  7. Microdosimetric evaluation of relative biological effectiveness for 103PD, 125I, 241AM, and 192IR brachytherapy sources

    International Nuclear Information System (INIS)

    Wuu, C.S.; Kliauga, P.; Zaider, M.; Amols, H.I.

    1996-01-01

    Purpose: To determine the microdosimetric-derived relative biological effectiveness (RBE) of 103 Pd, 125 I, 241 Am, and 192 Ir brachytherapy sources at low doses and/or low dose rates. Methods and Materials: The Theory of Dual Radiation Action can be used to predict expected RBE values based on the spatial distribution of energy deposition at microscopic levels from these sources. Single-event lineal energy spectra for these isotopes have been obtained both experimentally and theoretically. A grid-defined wall-less proportional counter was used to measure the lineal energy distributions. Unlike conventional Rossi proportional counters, the counter used in these measurements has a conducting nylon fiber as the central collecting anode and has no metal parts. Thus, the Z-dependence of the photoelectric effect is eliminated as a source of measurement error. Single-event spectra for these brachytherapy sources have been also calculated by: (a) the Monte Carlo code MCNP to generate the electron slowing down spectrum, (b) transport of monoenergetic electron tracks, event by event, with our Monte Carlo code DELTA, (c) using the concept of associated volume to obtain the lineal energy distribution f(y) for each monoenergetic electron, and (d) obtaining the composite lineal energy spectrum for a given brachytherapy source based on the electron spectrum calculated at step (a). Results: Relative to 60 Co, the RBE values obtained from this study are: 2.3 for 103 Pd, 2.1 for 125 I, 2.1 for 241 Am, and 1.3 for 192 Ir. Conclusions: These values are consistent with available data from in vitro cell survival experiments. We suggest that, at least for these brachytherapy sources, microdosimetry may be used as a credible alternative to time-consuming (and often uncertain) radiobiological experiments to obtain information on radition quality and make reliable predictions of RBE in low dose rate brachytherapy

  8. Gold nanoparticle-based brachytherapy enhancement in choroidal melanoma using a full Monte Carlo model of the human eye.

    Science.gov (United States)

    Asadi, Somayeh; Vaez-zadeh, Mehdi; Masoudi, S Farhad; Rahmani, Faezeh; Knaup, Courtney; Meigooni, Ali S

    2015-09-08

    The effects of gold nanoparticles (GNPs) in 125I brachytherapy dose enhancement on choroidal melanoma are examined using the Monte Carlo simulation technique. Usually, Monte Carlo ophthalmic brachytherapy dosimetry is performed in a water phantom. However, here, the compositions of human eye have been considered instead of water. Both human eye and water phantoms have been simulated with MCNP5 code. These simulations were performed for a fully loaded 16 mm COMS eye plaque containing 13 125I seeds. The dose delivered to the tumor and normal tissues have been calculated in both phantoms with and without GNPs. Normally, the radiation therapy of cancer patients is designed to deliver a required dose to the tumor while sparing the surrounding normal tissues. However, as the normal and cancerous cells absorbed dose in an almost identical fashion, the normal tissue absorbed radiation dose during the treatment time. The use of GNPs in combination with radiotherapy in the treatment of tumor decreases the absorbed dose by normal tissues. The results indicate that the dose to the tumor in an eyeball implanted with COMS plaque increases with increasing GNPs concentration inside the target. Therefore, the required irradiation time for the tumors in the eye is decreased by adding the GNPs prior to treatment. As a result, the dose to normal tissues decreases when the irradiation time is reduced. Furthermore, a comparison between the simulated data in an eye phantom made of water and eye phantom made of human eye composition, in the presence of GNPs, shows the significance of utilizing the composition of eye in ophthalmic brachytherapy dosimetry Also, defining the eye composition instead of water leads to more accurate calculations of GNPs radiation effects in ophthalmic brachytherapy dosimetry.

  9. Impact of target area selection in 125 Iodine seed brachytherapy on locoregional recurrence in patients with non-small cell lung cancer.

    Science.gov (United States)

    Yan, Wei-Liang; Lv, Jin-Shuang; Guan, Zhi-Yu; Wang, Li-Yang; Yang, Jing-Kui; Liang, Ji-Xiang

    2017-05-01

    Computed tomography (CT)-guided percutaneous implantation of 125 Iodine radioactive seeds requires the precise arrangement of seeds by tumor shape. We tested whether selecting target areas, including subclinical areas around tumors, can influence locoregional recurrence in patients with non-small cell lung cancer (NSCLC). We divided 82 patients with NSCLC into two groups. Target areas in group 1 (n = 40) were defined along tumor margins based on lung-window CT. Target areas in group 2 (n = 42) were extended by 0.5 cm in all dimensions outside tumor margins. Preoperative plans for both groups were based on a treatment plan system, which guided 125 I seed implantation. Six months later, patients underwent chest CT to evaluate treatment efficacy (per Response Evaluation Criteria in Solid Tumors version 1). We compared locoregional recurrences between the groups after a year of follow-up. We then used the treatment plan system to extend target areas for group 1 patients by 0.5 cm (defined as group 3 data) and compared these hypothetical group 3 planned seeds with the actual seed numbers used in group 1 patients. All patients successfully underwent implantation; none died during the follow-up period. Recurrence was significantly lower in group 2 than in group 1 ( P  area for 125 I seeds can decrease recurrence risk by eradicating cancerous lymph-duct blockades within the extended areas. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  10. Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGETM125I brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Hayes, Joshua L.; Zhang Hualin; Sowards, Keith

    2002-01-01

    125 I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, the ADVANTAGE TM 125 I, Model IAI-125, source became commercially available for interstitial brachytherapy treatment. Dosimetric characteristics (dose rate constant, radial dose function, and anisotropy function) of this source were experimentally and theoretically determined, following the AAPM Task Group 43 recommendations. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with their 1999 standard. Measurements were performed in Solid Water TM phantom using LiF thermoluminescent dosimeters. The theoretical calculations were performed in both Solid Water TM and water using the PTRAN Monte Carlo code. The results indicated that a dose rate constant of the new source in water was 0.98±0.03 cGy h -1 U -1 . The radial dose function of the new source was measured in Solid Water TM and calculated both in water and Solid Water TM at distances up to 10.0 cm. The anisotropy function, F(r,θ), of the new source was measured and calculated in Solid Water TM at distances of 2 cm, 3 cm, 5 cm, and 7 cm and also was calculated in water at distances ranging from 1 cm to 7 cm from the source. From the anisotropy function, the anisotropy factors and anisotropy constant were derived. The anisotropy constant of the ADVANTAGE TM 125 I source in water was found to be 0.97±0.03. The dosimetric characteristics of this new source compared favorably with those from the Amersham Health Model 6711 source. Complete dosimetric parameters of the new source are presented in this paper

  11. In vivo imaging of insulin receptors by PET: preclinical evaluation of iodine-125 and iodine-124 labelled human insulin

    International Nuclear Information System (INIS)

    Iozzo, P.; Osman, S.; Glaser, M.; Knickmeier, M.; Ferrannini, E.; Pike, V.W.; Camici, P.G.; Law, M.P.

    2002-01-01

    [A 14 -*I]iodoinsulin was prepared for studies to assess the suitability of labeled iodoinsulin for positron emission tomography (PET). Iodine-125 was used to establish the methods and for preliminary studies in rats. Further studies and PET scanning in rats were carried out using iodine-124. Tissue and plasma radioactivity was measured as the uptake index (UI={cpm·(g tissue) -1 }/{cpm injected·(g body weight) -1 }) at 1 to 40 min after intravenous injection of either [A 14 - 125 I]iodoinsulin or [A 14 - 124 I]iodoinsulin. For both radiotracers, initial clearance of radioactivity from plasma was rapid (T 1/2 ∼ 1 min), reaching a plateau (UI = 2.8) at ∼ 5 min which was maintained for 35 min. Tissue biodistributions of the two radiotracers were comparable; at 10 min after injection, UI for myocardium was 2.4, liver, 4.0, pancreas, 5.4, brain, 0.17, kidney, 22, lung, 2.3, muscle, 0.54 and fat, 0.28. Predosing rats with unlabelled insulin reduced the UI for myocardium (0.95), liver (1.8), pancreas (1.2) and brain (0.08), increased that for kidney (61) but had no effect on that for lung (2.5), muscle (0.50) or fat (0.34). Analysis of radioactivity in plasma demonstrated a decrease of [ 125 I]iodoinsulin associated with the appearance of labeled metabolites; the percentage of plasma radioactivity due to [ 125 I]iodoinsulin was 40% at 5 min and 10% at 10 min. The heart, liver and kidneys were visualized using [ 124 I]iodoinsulin with PET

  12. Regulation of autophagy via PERK-eIF2α effectively relieve the radiation myelitis induced by iodine-125.

    Directory of Open Access Journals (Sweden)

    Zuozhang Yang

    Full Text Available Radiation myelitis is the most serious complication in clinical radiotherapy for spinal metastases. We previously showed that (125I brachytherapy induced apoptosis of spinal cord neurons accompanied by autophagy. In this study, we further investigated the mechanism by which (125I radiation triggered autophagy in neural cells. We found that autophagy induced by (125I radiation was involved in endoplasmic reticulum (ER stress and mainly dependent on PERK-eIF2α pathway. The expressions of LC3II, ATG12 and PI3K were significantly suppressed in PERK knockout neural cells. Meanwhile, the expressions of phosphorylated-Akt s473 and caspase3/8 all significantly increased in neural cells transfected with a PERK siRNA and which enhanced apoptosis of neurons after (125I radiation. The results were consistent with that by MTT and Annexin-FITC/PT staining. In animal model of banna pigs with radiation myelitis caused by (125I brachytherapy, we have successfully decreased PERK expression by intrathecal administration of the lentivirus vector. The apoptosis rate was significantly higher than that in control group and which deteriorated radiation myelitis of banna pigs. Thus, autophagy caused by (125I radiation was mainly as an attempt of cell survival at an early stage, but it would be a self-destructive process and promoted the process of apoptosis and necrosis radiated by (125I for more than 72 hours. The study would be useful and helpful to maximize efficiency of radiation therapy in clinical therapy.

  13. Evaluation of material heterogeneity dosimetric effects using radiochromic film for COMS eye plaques loaded with 125I seeds (model I25.S16)

    International Nuclear Information System (INIS)

    Acar, Hilal; Chiu-Tsao, Sou-Tung; Özbay, İsmail; Kemikler, Gönül; Tuncer, Samuray

    2013-01-01

    Purpose: (1) To measure absolute dose distributions in eye phantom for COMS eye plaques with 125 I seeds (model I25.S16) using radiochromic EBT film dosimetry. (2) To determine the dose correction function for calculations involving the TG-43 formalism to account for the presence of the COMS eye plaque using Monte Carlo (MC) method specific to this seed model. (3) To test the heterogeneous dose calculation accuracy of the new version of Plaque Simulator (v5.3.9) against the EBT film data for this seed model. Methods: Using EBT film, absolute doses were measured for 125 I seeds (model I25.S16) in COMS eye plaques (1) along the plaque's central axis for (a) uniformly loaded plaques (14–20 mm in diameter) and (b) a 20 mm plaque with single seed, and (2) in off-axis direction at depths of 5 and 12 mm for all four plaque sizes. The EBT film calibration was performed at 125 I photon energy. MC calculations using MCNP5 code for a single seed at the center of a 20 mm plaque in homogeneous water and polystyrene medium were performed. The heterogeneity dose correction function was determined from the MC calculations. These function values at various depths were entered into PS software (v5.3.9) to calculate the heterogeneous dose distributions for the uniformly loaded plaques (of all four sizes). The dose distributions with homogeneous water assumptions were also calculated using PS for comparison. The EBT film measured absolute dose rate values (film) were compared with those calculated using PS with homogeneous assumption (PS Homo) and heterogeneity correction (PS Hetero). The values of dose ratio (film/PS Homo) and (film/PS Hetero) were obtained. Results: The central axis depth dose rate values for a single seed in 20 mm plaque measured using EBT film and calculated with MCNP5 code (both in ploystyrene phantom) were compared, and agreement within 9% was found. The dose ratio (film/PS Homo) values were substantially lower than unity (mostly between 0.8 and 0.9) for all

  14. Iodine-125--digoxin radioimmunoassay: comparison of commercial kits

    International Nuclear Information System (INIS)

    Battaglia, D.J.; Cianci, M.L.

    1976-01-01

    Iodine-125-digoxin radioimmunoassay kits available from Abbott Diagnostics (AD), Dade Division (D), Schwarz/Mann (SM), and Clinical Assays (CA) were evaluated with respect to assay quality. The kit accuracies did not differ significantly at 2.0 ng/ml and the interassay coefficients of variation ranged from 9 percent (AD) to 21.4 percent (CA). The accuracy for all kits above 4 ng/ml is questionable, and since serum-dilution values correlated well with undiluted serum values, the dilution method of dose quantitation is preferable for levels above 4 ng/ml. Although all the kits were adequate for evaluating digoxin at the 2 ng/ml level, the Abbott kit seems to be of slightly better quality

  15. Dosimetric studies, spectrometric, radiographic, metallographic of a new argentinean seed of {sup 125} I used in brachytherapy; Estudios dosimetricos, espectrometricos, radiograficos, metalograficos de una nueva semilla argentina de {sup 125}I empleada en braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Pirchio, R.; Saravi, M.; Banchik, D.; Munoz, C. [CNEA, Pbro. J. Gonzalez y Aragon No. 15 (B1802AYA), Ezeiza, Buenos Aires (Argentina)]. e-mail: pirchio@cae.cnea.gov.ar

    2006-07-01

    A new source of {sup 125} I model Braquibac{sup TM} has been developed in Argentina for applications in interstitial brachytherapy. The AAPM Task Group 43 (TG-43) recommends that dosimetric characteristics of new sources of brachytherapy of Iodine-125 have been theoretically and experimentally determined before its clinical use. The objectives outlined in this work were the study of the design of the new seed, the calculation of dosimetric parameters and the photons spectra analysis. Its were carried out radiographic and metallographic studies to determine the physical characteristics of the source. For the realization of the dosimetric calculations it was used the Monte Carlo code MCNP5. Values of the radial dose function, g(r), of the constant of dose rate, {lambda}, of the function of anisotropy of two dimensions, F(r, {theta}), of the factor and constant of anisotropy its were obtained simulating the source in water according to the recommended methodology in TG-43. The constant of dose rate is similar to 0,880 {+-} 0,080 c Gy h{sup -1} U{sup -1}. The kerma in air rate of reference, S{sub K}, was calculated as 1,036 c Gy cm{sup 2}h{sup -1} mCi{sup -1} simulating the seed in dry air. Its were carried out spectrometric studies using a semiconductor planar detector of HPGe (high purity germanium). Photons spectra showed characteristic x-rays of {sup 125} I with energies of 27,20 keV, 27,47 keV, 31 keV and 31,70 keV gamma photons of 35,5 keV, and x-ray fluorescent coming from the silver nucleus of 22,10 keV, 24,94 keV and 25,45 keV. The angular dependence of the intensity of photons around the seed and in air it was analyzed with the planar detector. This was carried out to study the anisotropy in the photons flow due to variation in the thickness of the titanium wall and of the welding, movements of the silver tube inside the source and deposition of the radioactive material on the silver tube. (Author)

  16. SU-E-T-15: A Comparison of COMS and EP917 Eye Plaque Applicators Using Different Radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Aryal, P; Molloy, JA [University of Kentucky, Lexington, KY (United States); Rivard, MJ [Tufts University School of Medicine, Boston, MA (United States)

    2015-06-15

    Purpose: To investigate the effect of plaque design and radionuclides on eye plaque dosimetry. Methods: The Monte Carlo N-particle Code version 6 (MCNP6) was used for radiation transport simulations. The 14 mm and 16 mm diameter COMS plaques and the model EP917 plaque were simulated using brachytherapy seeds containing I-125, Pd-103, and Cs-131 radionuclides. The origin was placed at the scleral inner surface. The central axis (CAX) doses of both COMS plaques at −1 mm, 0 mm, 1 mm, 2 mm, 5 mm, 10 mm, 15 mm, 20 mm, and 22.6 mm were compared to the model EP917 plaque. Dose volume histograms (DVHs) were also created for both COMS plaques for the tumor and outer sclera then compared to results for the model EP917 plaque. Results: For all radionuclides, the EP917 plaque delivered higher dose (max 343%) compared to the COMS plaques, except for the 14 mm COMS plaque with Cs-131 at 1 mm and 2 mm depths from outer sclera surface. This could be due to source design. For all radionuclides, the 14 mm COMS plaque delivered higher doses compared to the 16 mm COMS plaque for the depths up to 5 mm. Dose differences were not significant beyond depths of 10 mm due to ocular lateral scatter for the different plaque designs. Tumor DVHs for the 16 mm COMS plaque with Cs-131 provided better dose homogeneity and conformity compared to other COMS plaques with I-125 and Pd-103. Using Pd-103, DVHs for the 16 mm COMS plaque delivered less dose to outer sclera compared to other plaques. Conclusion: This study identified improved tumor homogeneity upon considering radionuclides and plaque designs, and found that scleral dose with the model EP917 plaque was higher than for the 16 mm COMS plaque for all the radionuclides studied.

  17. Prostate cancer brachytherapy

    International Nuclear Information System (INIS)

    Abreu, Carlos Eduardo Vita; Silva, Joao L. F.; Srougi, Miguel; Nesrallah, Adriano

    1999-01-01

    The transperineal brachytherapy with 125 I/Pd 103 seed implantation guided by transurethral ultrasound must be presented as therapeutical option of low urinary morbidity in patients with localized prostate cancer. The combined clinical staging - including Gleason and initial PSA - must be encouraged, for definition of a group of low risk and indication of exclusive brachytherapy. Random prospective studies are necessary in order to define the best role of brachytherapy, surgery and external beam radiation therapy

  18. Visual acuity after Ruthenium106 brachytherapy of choroidal melanomas

    International Nuclear Information System (INIS)

    Damato, Bertil; Patel, Imran M.; Campbell, Ian R.; Mayles, Helen M.; Errington, R. Douglas

    2005-01-01

    Purpose: To report on conservation of visual acuity after Ruthenium 106 (Ru-106) brachytherapy of choroidal melanoma. Methods and materials: This study was a noncomparative interventional case series of 458 patients with choroidal melanoma treated at a single center between January 1993 and December 2001. The intervention consisted of Ru-106 brachytherapy delivering minimum scleral and apex doses of 300 Gy and 80 Gy, respectively, using a 15-mm or 20-mm plaque. For discrete, posterior tumors, the plaque was positioned eccentrically with its posterior edge aligned with the posterior tumor margin. To ensure correct plaque positioning, any overlying extraocular muscles were dis-inserted, and the locations of both tumor and plaque edges were confirmed by transillumination and indentation. The main outcome measures were conservation of vision of 20/40 or better, 20/200 or better, and Counting Fingers or better, according to baseline variables. Results: The actuarial rate of conservation of 20/40 or better was 55% at 9 years, loss of such vision correlating with posterior tumor extension (p 106 brachytherapy of posterior choroidal melanoma achieves good conservation of vision if the tumor does not extend close to the optic nerve or fovea

  19. Influence of modifications in the positioning of phantoms in the Monte Carlo computational simulation of the prostate brachytherapy

    International Nuclear Information System (INIS)

    Barbosa, Antonio Konrado de Santana; Vieira, Jose Wilson; Costa, Kleber Souza Silva; Lima, Fernando Roberto de Andrade

    2011-01-01

    Radiotherapy simulation procedures using Monte Carlo methods have shown to be increasingly important to the improvement of cancer fighting strategies. Within this context, brachytherapy is one of the most used methods to ensure better life quality when compared to other therapeutic modalities. These procedures are planned with the use of sectional exams with the patient in lying position. However, it is known that alteration of body posture after the procedure has an influence in the localization of many organs. This study had the aim to identify and to measure the influence of such alterations in MC brachytherapy simulations. In order to do so, prostate brachytherapy with the use of Iodine-125 radionuclide was chosen as model. Simulations were carried out with 108 events using EGSnrc code associated to MASH phantom in orthostatic and supine positions. Significant alterations were found, especially regarding bladder, small intestine and testicles. (author)

  20. Iodine-125 Nilutamide as Novel Radio-therapeutic Ligand for Androgen Receptor in Prostate Cancer

    International Nuclear Information System (INIS)

    Amin, A.M.; EL-Ghany, E.A.; Moustafa, D.

    2009-01-01

    Nilutamide is potent anti-androgen that is used in patients with metastatic prostate carcinoma. The labeling of nilutamide with iodine radioisotopes give an advantage to localize these radionuclides in prostate for imaging and/or therapy depending on the radionuclide used. During this study, nilutamide was labeled successfully with iodine-125 in a neutral ph medium using chloramine-T as oxidizing agent and the radiochemical yield obtained was greater than 96%. The biodistribution of the iodine-125-nilutamide in normal mice indicated the ability of the tracer to bind with specific receptors in prostate and other male organs with 3.5 % at 4 hours post injection. The clearance of the tracer from the blood pool was slow and equal to 40% of the initial blood uptake at 4 hours post injection. The in vivo stability of the tracer was established by the absence of the thyroid uptake. The competition binding was achieved via 1M injection of testosterone and IV injection of non-labeled nilutamide 2 hours before the administration of the tracer. The results referred to a significant reduction in the uptake of the tracer by the prior administration of testosterone and non-labeled nilutamide by 60% and 30%, respectively at 4 hours post injection

  1. Multistation iodine-125 continuous air monitor with minicomputer alarm and data reduction

    International Nuclear Information System (INIS)

    Garfield, D.K.

    1978-01-01

    The components, operation, and calibration are described of a Multistation Continuous Air Monitor for the analysis of Iodine-125 and the functions of the Minicomputer in providing alarm functions and data reduction to units specified by regulation for permanent records. The sensitivity and accuracy, as well as the justification for purchase and comparison of costs with other types of air monitoring systems are also described

  2. 125brachytherapy of locally advanced non-small-cell lung cancer after one cycle of first-line chemotherapy:a comparison with best supportive care

    Directory of Open Access Journals (Sweden)

    Song J

    2017-03-01

    Full Text Available Jingjing Song* Xiaoxi Fan* Zhongwei Zhao* Minjiang Chen* Weiqian Chen, Fazong Wu, Dengke Zhang, Li Chen, Jianfei Tu, Jiansong Ji Department of Interventional Radiology, Zhejiang University Lishui Hospital, The Fifth Affiliated Hospital of Wenzhou Medical University, Lishui Central Hospital, Lishui, Zhejiang, People’s Republic of China *These authors have contributed equally to this work Objectives: The objective of this study was to assess the efficacy of computed tomography (CT-guided 125I brachytherapy alone in improving the survival and quality of life of patients with unresectable locally advanced non-small-cell lung cancer (NSCLC after one cycle of first-line chemotherapy.Patients and methods: Sixteen patients with locally advanced NSCLC were treated with CT-guided 125I brachytherapy after one cycle of first-line chemotherapy (group A. Sixteen patients who received only best supportive care (group B were matched up with the patients in group A. Primary end point included survival, and secondary end point included assessment of safety, effectiveness of CT-guided 125I brachytherapy, and improvement in the quality of life.Results: The two groups were well balanced in terms of age, disease histology, tumor stage, tumor location, and performance status (P>0.05. The median follow-up time was 16 months (range, 3–30. The total tumor response rate was 75.0% in group A, which was significantly higher than that in group B (0.0% (P<0.01. The median progression-free survival time was 4.80 months for patients in group A and 1.35 months for patients in group B (P<0.001. Kaplan–Meier survival analysis showed that the median survival time of group A was 9.4±0.3 months versus 8.4±0.1 months in group B (P=0.013. Tumor-related symptoms of patients were significantly relieved, and the quality of life was markedly improved in group A than in group B.Conclusion: CT-guided 125I brachytherapy improved the survival of patients with locally advanced

  3. Iodine-125 metaraminol: A new platelet specific labeling agent

    International Nuclear Information System (INIS)

    Ohmomo, Y.; Yokoyama, A.; Kawaii, K.; Horiuchi, K.; Saji, H.; Torizuka, K.

    1984-01-01

    In the search for a platelet specific labeling agent, Metaraminol (MA), which is a sympatomimetic amine used for the treatment of hypotension, cardiogenic shock and well recognized as a drug actively incorporated and accumulated in platelet, attracted the authors' attention. Using the classical chloramine-T iodination method, a high labeling efficiency near 98%, reaching a specific activity up to about 1000 Ci/mmole was obtained. Upon the harvest of platelet, only as platelet rich plasma (PRP), the labeling with this radiopharmaceutical was easily performed by incubation at 37 0 C for 10 min. Labeling efficiency as high as 63.0 +- 3.1% at 24 x 10/sup 8/ cells/ml was obtained. In in-vitro studies, the unaltered state of I-125 MA labeled platelet, with their cellular functions fully retained was demonstrated. Pharmacological study indicated a specific incorporation of I-125 MA by active transport system similar to that of 5-HT, along with passive diffusion. Then the in-vivo study carried out in rabbits with induced thrombi on the femoral artery, showed rather rapid disappearance of the I-125 MA labeled autologous platelet radioactivity, from circulating blood reaching as high thrombus-to-blood activity ratio as 19.8+-4.3 within 30 min post-administration. This new platelet labeling agent, I-125 MA, has many advantages over the use of IN-111 oxine and holds considerable promise for thrombus imaging with single photon emission CT upon the availability of I-123 MA

  4. Study of CT-guided iodine-125 implantation in the treatment of rabbit VX2 tumor

    International Nuclear Information System (INIS)

    He Kewu; Gao Bin; Li Jiajia

    2008-01-01

    Objective: To evaluate the effect of CT-guided iodine-125 seed( 125 I) implantation to rabbit model VX2 tumor cell apoptosis. Methods: VX2 tumor cells were implanted into muscle of 40 rabbits legs, 3 weeks later, as the diameter of tumor reached 2 cm available for test. Randomly selected the sampling tumor on one leg of rabbit as for the test team and tumor on the contralateral leg as for control team. Under CT guidance, 125 I seeds were implanted into 20 tumor lesions of the test team, and hollow seeds were implanted into 20 tumor lesions of the control team. Instantly, 72 h, 1, 2, 3 w after operation, percutaneous tumor tissue sampling was done 0.5-1.0 cm and 1.0-1.5 cm away from seed implanted site under CT guidance; and apoptosis was investigated by FCM. Results: Instantly, 72 h, 1, 2, 3 w after treatment with iodine-125 ( 125 I) implantation, the tissue sampling away from seed 0.5-1.0 cm showed the apoptosis rates of control team and test team were respectively as follows: (5.43±0.67)% and (5.48±0.66)%, (P>0.05), (5.45±0.58)% and (11.60±0.87)%, (P O.05)of the control team and test team. Conclusions: 125 I seeds implantation can induce tumor cell apoptosis, beginning at 72 h and reached peak at 2 w and kept the high level here afterword. The apoptosis rate descended rapidly along with the increase of distance away from the 125 I seedling. (authors)

  5. SU-E-T-12: A Comparative Dosimetric Study of Pre and Post Prostate Iodine-125 Permanent Seed Implants

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X; Rahimian, J; Goy, B; Cosmatos, H; Qian, Y [Kaiser Permanente, Los Angeles, CA (United States)

    2015-06-15

    Purpose: Post-implant dosimetry has become the gold standard for prostate implant evaluation. The goal of this research is to compare the dosimetry between pre-plan and post-plan in permanent prostate seed implant brachytherapy. Methods: A retrospective study of 91 patients treated with Iodine-125 prostate seed implant between year 2012∼2014 were performed. All plans were created using a VariSeed 8.0 planning system. Pre-plan ultrasound images were acquired using 0.5 cm slice thickness. Post-plan CT images acquired about 1–4 weeks after implant, fused with the preplan ultrasound images. The prostate and urethra contours were generated using the fusion of ultrasound and CT images. Iodine-125 seed source activities varied between 0.382 to 0.414 mCi per seed. The loading patterns varied slightly between patients depending on the prostate size. Statistical analysis of pre and post plans for prostate and urethra volumes, V100%, V150% and D90, and urethra D10 were performed and reported. Results: The pre and post implant average prostate size was 36.90cc vs. 38.58cc; V100% was 98.33% vs. 96.89%; V150% was 47.09% vs. 56.95%; D90 was 116.35Gy vs. 116.12Gy, urethra volume was 1.72cc vs. 1.85cc, urethra D10% was 122.0% vs. 135.35%, respectively. There was no statistically significant difference between the pre and post-plan values for D90(p-value=0.43). However, there are significant differences between other parameters most likely due to post surgical edema; prostate size (p-value= 0.00015); V100% (p-value=3.7803E-07); V150% (p-value=1.49E-09); urethra volume (p-value= 2.77E-06); Urethra D10 (p-value=7.37E-11). Conclusion: The post-plan dosimetry using CT image set showed similar D90 dose coverage to the pre-plan using the ultrasound image dataset. The study showed that our prostate seed implants have consistently delivered adequate therapeutic dose to the prostate while sparing urethra. Future studies to correlate dose versus biochemical response using patients’ PSA

  6. Analysis of the radiobiology of ytterbium-169 and iodine-125 permanent brachytherapy implants

    Energy Technology Data Exchange (ETDEWEB)

    Lazarescu, G.R. [Windsor Regional Cancer Center, Ontario Cancer Treatment and Research Foundation, Windsor, Canada N8W 2X3 (Canada); Battista, J.J. [London Regional Cancer Center, Ontario Cancer Treatment and Research Foundation, Dept. of Oncology and Dept. of Medical Biophysics, University of Western Ontario, London, Canada N6A 4L6 (Canada)

    1997-09-01

    Recently, Yb-169 has been considered as a potential replacement for I-125 and Pd-103 in permanent implants. In spite of the uncertainties in the parameters necessary for an accurate radiobiological modelling, the linear quadratic model can be useful in the comparative evaluation of the radiotherapeutic merit of similar implants. In order to find out if a Yb-169 permanent implant can be made biologically 'equivalent' to an I-125 implant, we studied the dependence of local control on the tumour cell radiosensitivity and on the balance between the rate of tumour cell killing and tumour cell proliferation, for rapidly and slowly proliferating tumours. The extrapolated response dose (ERD) has been calculated for tumour and late reacting normal tissue for both types of implants and the possible biological restrictions due to the normal tissue tolerance have been discussed. Our theoretical analysis is consistent with the clinical results published for I-125 permanent implants in prostate tumours and meningiomas. It predicts that Yb-169, which has only recently been used in human tumours, can provide comparable tumour control for permanent implants in slowly proliferating tumours with an initial dose rate of 13 cGy h{sup -1}. Control might be extended to rapidly proliferating tumours by increasing the initial dose rate within a range consistent with an acceptable level of normal tissue late reaction. (author)

  7. Influence of radioactive sources discretization in the Monte Carlo computational simulations of brachytherapy procedures: a case study on the procedures for treatment of prostate cancer

    International Nuclear Information System (INIS)

    Barbosa, Antonio Konrado de Santana; Vieira, Jose Wilson; Costa, Kleber Souza Silva; Lima, Fernando Roberto de Andrade

    2011-01-01

    Radiotherapy computational simulation procedures using Monte Carlo (MC) methods have shown to be increasingly important to the improvement of cancer fighting strategies. One of the biases in this practice is the discretization of the radioactive source in brachytherapy simulations, which often do not match with a real situation. This study had the aim to identify and to measure the influence of radioactive sources discretization in brachytherapy MC simulations when compared to those that do not present discretization, using prostate brachytherapy with Iodine-125 radionuclide as model. Simulations were carried out with 108 events with both types of sources to compare them using EGSnrc code associated to MASH phantom in orthostatic and supine positions with some anatomic adaptations. Significant alterations were found, especially regarding bladder, rectum and the prostate itself. It can be concluded that there is a need to discretized sources in brachytherapy simulations to ensure its representativeness. (author)

  8. Procedure for determination of the decontamination of piping in the production of iodine-125 seeds

    International Nuclear Information System (INIS)

    Moura, J.A.; Moura, E.S.; Sprenger, F.E.; Nagatomi, H.R.; Zeituni, C.A.; Feher, A.; Manzoli, J.E.; Souza, C.D.; Rostelato, M.E.C.M.

    2009-01-01

    Iodine-125 seeds are radioactive sources used in the prostate cancer treatment. This work objective was to determine the necessary conditions and procedures for decontamination of liquid transfer tubes when a radioactive material leakage occurs during the process of seed quality control

  9. PSA bounce after 125I-brachytherapy for prostate cancer as a favorable prognosticator

    International Nuclear Information System (INIS)

    Engeler, Daniel S.; Schwab, Christoph; Schmid, Hans-Peter; Thoeni, Armin F.; Hochreiter, Werner; Prikler, Ladislav; Suter, Stefan; Stucki, Patrick; Schiefer, Johann; Plasswilm, Ludwig; Putora, Paul Martin

    2015-01-01

    Permanent low-dose-rate brachytherapy (BT) with iodine 125 is an established curative treatment for localized prostate cancer. After treatment, prostate-specific antigen (PSA) kinetics may show a transient rise (PSA bounce). Our aim was to investigate the association of PSA bounce with biochemical control. Patients treated with BT in Switzerland were registered in a prospective database. Only patients with a follow-up of at least 2 years were included in our analysis. Clinical follow-up and PSA measurements were assessed after 1.5, 3, 6, and 12 months, and annually thereafter. If PSA increased, additional follow-up visits were scheduled. Cases of PSA bounce were defined as a rise of at least 0.2 ng/ml above the initial PSA nadir with a subsequent decline to or below the initial nadir without treatment. Biochemical failure was defined as a rise to nadir + 2 ng/ml. Between March 2001 and November 2010, 713 patients with prostate cancer undergoing BT with at least 2 years of follow-up were registered. Median follow-up time was 41 months. Biochemical failure occurred in 28 patients (3.9 %). PSA bounce occurred in 173 (24.3 %) patients; only three (1.7 %) patients with PSA bounce developed biochemical failure, in contrast to 25 (4.6 %) patients without previous bounce (p < 0.05). The median time to bounce was 12 months, the median time to biochemical failure was 30 months. The median bounce increase was 0.78 ng/ml. Twenty-eight patients with bounce (16.5 %) had a transient PSA rise of + 2 ng/ml above the nadir. In most cases, an early increase in PSA after BT indicates PSA bounce and is associated with a lower risk of biochemical failure. (orig.) [de

  10. A study of brachytherapy for intraocular tumor

    International Nuclear Information System (INIS)

    Ji, Yung Hoon; Lee, Dong Han; Ko, Kyung Hwan; Lee, Tae Won; Lee, Sung Koo; Choi, Moon Sik

    1994-12-01

    Our purpose of this study is to perform brachytherapy for intraocular tumor. The result were as followed. 1. Eye model was determined as a 25 mm diameter sphere. Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15 mm, 17 mm and 20 mm in diameter, and 1.5 mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5 mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ±10% and distance deviations are within 0.4 mm. Maximum error is -11.3% and 0.8 mm, respectively. 7 figs, 2 tabs, 28 refs. (Author)

  11. Use of iodine-125 brachytherapy in treatment of choroidal melanomas, technic and preliminary analysis of 78 patients; Traitement conservateur des melanomes choroidiens par curietherapie par l'iode 125, technique et analyse preliminaire d'une serie de 78 patients

    Energy Technology Data Exchange (ETDEWEB)

    Quetin, P.; Schumacher, C.; Schraub, S. [Centre Paul-Strauss, Dept. de Radiotherapie, 67 - Strasbourg (France); Meyer, L.; Polto, F.; Sahel, J. [Hopitaux Universitaires de Strasbourg, Clinique Ophtalmologique, 67 (France); Magnenet, P. [Centre Paul-Strauss, Dept. de Radiophysique, 67 - Strasbourg (France); Andres, E. [Hopital de Hautepierre, Medecine Interne, 67 - Strasbourg (France)

    2001-12-01

    Purpose. - Iodine 125 curietherapy is one of the conservative treatments of uveal melanoma. The technique used to achieve these results was simplified through the physical characteristics of the radioelement and the optimized-dosimetry program employed. Patients and methods. - 78 patients with choroidal melanoma were treated with iodine 125. About 100 Gy were delivered to the superior pole of the tumour. The minimal length of follow-up was 17 months and the average, 67 months. Results. -There was 88% local control, leading to lowered visual acuity in 76 % of the cases. Radiation retinopathy, directly related to proximity to the macula, is the principle etiology. Seven patients died of hepatic metastasis, five patients were enucleated. Four patients were further treated with proton-therapy to make up for non-control locally. Conclusion. -One dose of 100 Gy to the superior pole of the tumor seemed to lead to good local control, with the exception of complications related to proximity to the macula and the optic nerve. In this attempt to optimize irradiation, the time lapse between any benefit in local control derived from irradiation and post-therapeutic complications observed remains insufficient to evaluate any relationship. (authors)

  12. Brachytherapy with cobalt plaques in the conservative treatment of intraocular tumors. The hospital A.C. camargo experience

    International Nuclear Information System (INIS)

    Trippe, N.; Novaes, P.E.R.S.; Ferrigno, R.; Pellizzon, A.C.; Fogarolli, R.C.; Maia, M.A.C.; Salvajoli, J.V.; Baraldi, H.E.; Chojniak, M.M.; Erwene, CM

    1996-01-01

    From December 1989 to December 1993, 76 cases of intraocular tumors, including 56 adult patients with uveal melanomas and 20 children with retinoblastoma, were treated with exclusive intraocular brachytherapy with Cobalt plaques. The goal was to keep the vision function and at same time not compromising the chance of cure. The dose prescribed was 40Gy, calculated at the apex of the lesion for retinoblastomas and 100 to 120Gy for uveal melanomas. With the minimum follow up of 24 months, of the 56 patients with uveal melanomas, 41 (73,3%) had their vision preserved and 15 (26,4%) had local failure and were underwent enucleation. With the medium follow up of 27 months, 17 (85,5%) of the patients with retinoblastoma had their vision preserved, while 3 (15%) had local failure and were treated by enucleation. The grade I and II complications occurred in 9 (42,8%) patients and 100% of them are with no evidence of systemic disease. When well indicated, the conservative treatment of intraocular tumors with brachytherapy is a good alternative to enucleation and must be done by a multidisciplinary and well trained medical professional group

  13. The iodination(I-125) of follicle stimulating hormone, using N-bromosuccinimide, lactoperoxidase or iodo-beads oxidators

    International Nuclear Information System (INIS)

    Dj., Sukiyati; S., Wayan R.; M., Gina; Ariyanto, A.

    1992-01-01

    The iodination (I-125) of Follicle Stimulating Hormone, using N-bromosuccinimide, lactoperoxidase or iodo-beads oxidators. FSH 125 I is one of the FSH RIA Kit reagents utilized for the determination of FSH concentration in blood serum, to study the coordination disorder of the principal hormones, i.e. hypothalamus, pituitary and gonads. To produce a good quality of FSH 125 I as a component of FSH RIA Kit, a research on the iodination(I-125) of FSH employing mild oxidant N-bromosuccinimide, lactoperoxidase, and iodo-bead has been performed. The percentage of labelling, the immunology activity and Non Specific Binding(NSB) of the labelled products were determined. The immunology activity in (%) B/T and non specific binding (%) NSB were compared with Amersham FSH RIA Kit. By the N-bromosuccinimide method, the labelling obtained was 25%, immunology activity B/T 22% (Amersham 25%) and NSB 1.3% (Amersham 1.2%). The results of labelling employing lactoperoxidase was 8.2%, immunology activity B/T 34% (Amersham 38%) and NSB 2.6% (Amersham 0.8%). Whereas labelling with Iodo-beads method produce 18%, immunology activity B/T 25% (Amersham 35%) and NSB 0.6% (Amersham 0.7%). The labelled FSH 125 I was stable with in one month stored at 4 degrees centigrade. (authors). 7 refs., 4 tabs., 1 fig

  14. Characterization and storage of liquid wastes containing {sup 125}Iodine in the laboratory for production of brachytherapy sources - IPEN; Caracterização e armazenamento de rejeitos líquidos contendo Iodo-125 no Laboratório de Produção de fontes para braquiterapia - IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Vitória S.; Souza, Daiane C.B. de; Barbosa, Nayane K.O.; Rodrigues, Bruna T.; Nogueira, Beatriz R.; Costa, Osvaldo L. da; Zeituni, Carlos A.; Vicente, Roberto; Rostelato, Maria E.C.M., E-mail: vitoria.carvalho@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    Radioactive sources of Iodine-125 for medical applications have been developed at the Institute for Energy and Nuclear Research (IPEN) to meet the growing demand for medical applications such as brachytherapy. A dedicated laboratory is already being implemented at IPEN. Part of the processes involved in the production of sealed sources generate radioactive wastes that despite the short half-life (<100 days) have radioactive activity above the levels of exemption established by the Brazilian National Nuclear Energy Commission. Therefore, these wastes should receive appropriate treatment and storage until they reach the levels of release into the environment. This work aims to determine the volumes of the liquid wastes generated during the production stages of the sources, as well as to propose a temporary storage system for such wastes. The applied methodology consisted in determining the volumes of wastes generated in each production cell according to the manufacturing steps. After that, activities and activity concentrations were calculated for each container used for temporary storage inside the production laboratory. The total volume stored for one year in the temporary storage, as well as the rate of entry and exit of the liquid wastes were calculated according to the source production demand and the decay time of the radionuclide, respectively. The main results showed that the time required to reach sanitary sewage disposal values is within the period of operation of the facility. The total volume generated is also within the facility's temporary storage capacity.

  15. Optical fibre luminescence sensor for real-time LDR brachytherapy dosimetry

    Science.gov (United States)

    Woulfe, P.; O'Keeffe, S.; Sullivan, F. J.

    2018-02-01

    An optical fibre sensor for monitoring low dose radiation is presented. The sensor is based on a scintillation material embedded within the optical fibre core, which emits visible light when exposed to low level ionising radiation. The incident level of ionising radiation can be determined by analysing the optical emission. An optical fibre sensor is developed, based on radioluminescence whereby radiation sensitive scintillation material, terbium doped gadolinium oxysulphide (Gd2O2S:Tb), is embedded in a cavity of 700μm of a 1mm plastic optical fibre. The sensor is designed for in-vivo monitoring of the radiation dose during radio-active seed implantation for low dose rate (LDR) brachytherapy, in prostate cancer treatment, providing radiation oncologists with real-time information of the radiation dose to the target area and/or nearby organs at risk (OARs). The radiation from the brachytherapy seeds causes emission of visible light from the scintillation material through the process of radioluminescence, which penetrates the fibre, propagating along the optical fibre for remote detection using a multi-pixel photon counter. The sensor demonstrates a high sensitivity to 0.397mCi of Iodine125, the radioactive source most commonly used in brachytherapy for treating prostate cancer.

  16. Design and dosimetry of an eye plaque containing I-125 seeds: An improved dose distribution

    International Nuclear Information System (INIS)

    Detorie, N.A.; Tkacik, M.F.; Neglia, W.J.; Jenkins, D.; Shadday, J.

    1986-01-01

    To treat intraocular tumors, a temporarily implanted eye plaque, containing 24 I-125 seeds (3M model 6711), was fabricated from 0.6-mm-thick lead disk with a 1.5-cm diameter. The I-125 seeds were distributed in a particular geometric pattern to average the dose anisotropy of each individual seed. Water phantom measurements made with TLD chips (LiF) and film over the approximate depth range of 1-25 mm were compared with treatment planning computer calculations (Capintec RT-108). Data indicate that the specified geometry produces a dose distribution delivering a tumor dose of 10,000 rad to the tumor apex (7 mm) without exceeding a sclera dose (1 mm) of 40,000 rad. Information regarding fabrication, dosimetry, and radiation safety is presented

  17. Synthesis and biologic studies of iodinated (125I/127I) ethidium

    International Nuclear Information System (INIS)

    Ho Nanhui; Tumeh, Paul C.; Kassis, Amin I.

    2001-01-01

    An iodinated ( 125 I/ 127 I) ethidium derivative (3,8-diamino-5-[6'-(p-iodobenzoylamino)-4'-azahexyl]-6 -phenylphenanthridinium chloride hydrochloride) was synthesized and characterized. The labeling yield of the 125 I-labeled derivative was 75% for carrier-free 125 I, with a radiochemical purity of 95%. The incubation of iodoethidium with calf thymus DNA resulted in a substantial enhancement of fluorescence yield, indicating the intercalation of this compound into DNA. In the presence of iodoethidium, the nuclei of methanol-treated mammalian cells fluoresced, while those of viable cells did not (since the plasma membrane is impermeable to iodoethidium). When viable cells were incubated with the reduced form of the derivative, 125 I/ 127 I-dihydroethidium traversed the plasma membrane, was oxidized in the cytoplasm, and intercalated into nuclear DNA. Finally, we tested the hypothesis that larger malignant solid tumors, containing a relatively greater percentage of degenerating permeable cells, can be targeted with 125 I-ethidium. In-vivo studies demonstrated a small but positive correlation (R = 0.72) between tumor volume and the uptake of the derivative. Because of the ubiquitous presence of abnormal permeable cells and necrosis in tumors, our results support the belief that radiolabeled DNA-intercalating or DNA-binding molecules may be of diagnostic and therapeutic value for a variety of solid tumors in humans

  18. Comparison of iodinated contrast media for the assessment of atherosclerotic plaque attenuation values by CT coronary angiography: Observations in an ex vivo model

    NARCIS (Netherlands)

    L. la Grutta (Ludovico); M. Galia (Massimo); G. Gentile; G. Lo Re (G.); E. Grassedonio (Emanuele); F. Coppolino; E. Maffei (Erica); E. Maresi (E.); A. Lo Casto (A.); F. Cademartiri (Filippo); M. Midiri (Massimo)

    2013-01-01

    textabstractObjective: To compare the influence of different iodinated contrast media with several dilutions on plaque attenuation in an ex vivo coronary model studied by multislice CT coronary angiography. Methods: In six ex vivo left anterior descending coronary arteries immersed in oil, CT

  19. SU-F-T-51: Investigating the Effect of Eye Size and Eccentricity On Normal Tissue Doses From Eye Plaque Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Polsdofer, E; Crilly, R [Oregon Health & Science University Portland, OR (United States)

    2016-06-15

    Purpose: This study investigates the effect of eye size and eccentricity on doses to critical tissues by simulating doses in the Plaque Simulator (v. 6.3.1) software. Present OHSU plaque brachytherapy treatment focuses on delivering radiation to the tumor measured with ocular ultrasound plus a small margin and assumes the orbit has the dimensions of a “standard eye.” Accurately modeling the dimensions of the orbit requires a high resolution ocular CT. This study quantifies how standard differences in equatorial diameters and eccentricity affect calculated doses to critical structures in order to query the justification of the additional CT scan to the treatment planning process. Methods: Tumors of 10 mm × 10 mm × 5 mm were modeled at the 12:00:00 hour with a latitude of 45 degrees. Right eyes were modeled at a number of equatorial diameters from 17.5 to 28 mm for each of the standard non-notched COMS plaques with silastic inserts. The COMS plaques were fully loaded with uniform activity, centered on the tumor, and prescribed to a common tumor dose (85 Gy/100 hours). Variations in the calculated doses to normal structures were examined to see if the changes were significant. Results: The calculated dose to normal structures show a marked dependence on eye geometry. This is exemplified by fovea dose which more than doubled in the smaller eyes and nearly halved in the larger model. Additional significant dependence was found in plaque size on the calculated dose in spite of all plaques giving the same dose to the prescription point. Conclusion: The variation in dose with eye dimension fully justifies the addition of a high resolution ocular CT to the planning technique. Additional attention must be made to plaque size beyond simply covering the tumor when considering normal tissue dose.

  20. SU-F-T-46: The Effect of Inter-Seed Attenuation and Tissue Composition in Prostate 125I Brachytherapy Dose Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, K; Araki, F; Ohno, T [Kumamoto University, Kumamoto, Kumamoto (Japan)

    2016-06-15

    Purpose: To investigate the difference of dose distributions with/without the effect of inter-seed attenuation and tissue compositions in prostate {sup 125}I brachytherapy dose calculations, using Monte Carlo simulations of Particle and Heavy Ion Transport code System (PHITS). Methods: The dose distributions in {sup 125}I prostate brachytherapy were calculated using PHITS for non-simultaneous and simultaneous alignments of STM1251 sources in water or prostate phantom for six patients. The PHITS input file was created from DICOM-RT file which includes source coordinates and structures for clinical target volume (CTV) and organs at risk (OARs) of urethra and rectum, using in-house Matlab software. Photon and electron cutoff energies were set to 1 keV and 100 MeV, respectively. The dose distributions were calculated with the kerma approximation and the voxel size of 1 × 1 × 1 mm{sup 3}. The number of incident photon was set to be the statistical uncertainty (1σ) of less than 1%. The effect of inter-seed attenuation and prostate tissue compositions was evaluated from dose volume histograms (DVHs) for each structure, by comparing to results of the AAPM TG-43 dose calculation (without the effect of inter-seed attenuation and prostate tissue compositions). Results: The dose reduction due to the inter-seed attenuation by source capsules was approximately 2% for CTV and OARs compared to those of TG-43. In additions, by considering prostate tissue composition, the D{sub 90} and V{sub 100} of CTV reduced by 6% and 1%, respectively. Conclusion: It needs to consider the dose reduction due to the inter-seed attenuation and tissue composition in prostate {sup 125}I brachytherapy dose calculations.

  1. Comparative dosimetry of prostate brachytherapy with I-125 and Pd-103 seeds via SISCODES/MCNP

    Energy Technology Data Exchange (ETDEWEB)

    Trindade, Bruno Machado; Falcao, Patricia Lima, E-mail: bmtrindade@yahoo.com [Nucleo de Radiacoes Ionizantes - Universidade Federal de Minas Gerais (NRI/UFMG), Belo Horizonte, MG (Brazil); Christovao, Marilia Tavares [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Trindade, Daniela de Fatima Maia [Centro Universitario Una, Belo Horizonte, MG (Brazil); Campos, Tarcisio Passos Ribeiro de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2012-09-15

    Objective: The present paper is aimed at presenting a comparative dosimetric study of prostate brachytherapy with I-125 and Pd-103 seeds. Materials and Methods: A protocol for both implants with 148 seeds was simulated on a heterogeneous three-dimensional pelvic phantom by means of the SISCODES/MCNP5 codes. Dose-volume histograms on prostate, rectum and bladder, dose indexes D10, D30, D90, D0.5cc, D2cc and D7cc, and representations of the spatial dose distribution were evaluated. Results: For a D90 index equivalent to the prescription dose, the initial activity of each I-125 seed was calculated as 0.42 mCi and of Pd-103 as 0.94 mCi. The maximum dose on the urethra was 90% and 108% of the prescription dose for I-125 and Pd-103, respectively. The D2cc for I-125 was 30 Gy on the rectum and 127 Gy on the bladder; for Pd-103 was 29 Gy on the rectum and 189 Gy on the bladder. The D10 on the pubic bone was 144 Gy for I-125 and 66 Gy for Pd-103. Conclusion: The results indicate that Pd-103 and I-125 implants could deposit the prescribed dose on the target volume. Among the findings of the present study, there is an excessive radiation exposure of the pelvic bones, particularly with the I-125 protocol. (author)

  2. The preparation of 125I - gastrin I and 125 - minigastrin for medical diagnostics

    International Nuclear Information System (INIS)

    Byszewska-Szpocinska, E.; Markiewicz, A.

    2002-01-01

    Gastrin I G-17 and minigastrin G-13 were iodinated using direct methods with chloramin T and iodogen procedures and by indirect method with Bolton-Hunter reagent. 125 I - gastrin and 1 25 I - minigastrin were isolated from the iodination mixtures by gel filtration on Sephadex G-10 and Sephadex G-25 (PD-10 column) and by HPLC system (Lichrospher WP-300-RP-18 column). Radiochemical purity was shown by HPLC also. It was confirmed that iodogen procedure is the best for iodination of these peptides. 125 I - gastrin I obtained by this method with specific activity 80 μCi/nmol was homogeneous but iodination to higher specific activity (440μCi/nmol) caused appearance of two subfractions. 125 I - minigastrin with high and low specific activity were isolated by HPLC as the two forms (subfractions). It was shown that high performance liquid chromatography (HPLC) was the best method for isolation and purification of 125 I - gastrin I and 125 I - minigastrin. (author)

  3. Radioimmunoguided surgery using iodine 125 B72.3 in patients with colorectal cancer

    International Nuclear Information System (INIS)

    Cohen, A.M.; Martin, E.W. Jr.; Lavery, I.; Daly, J.; Sardi, A.; Aitken, D.; Bland, K.; Mojzisik, C.; Hinkle, G.

    1991-01-01

    Preliminary data using B72.3 murine monoclonal antibody labeled with iodine 125 suggested that both clinically apparent as well as occult sites of colorectal cancer could be identified intraoperatively using a hand-held gamma detecting probe. We report the preliminary data of a multicenter trial of this approach in patients with primary or recurrent colorectal cancer. One hundred four patients with primary, suspected, or known recurrent colorectal cancer received an intravenous infusion of 1 mg of B72.3 monoclonal antibody radiolabeled with 7.4 x 10 Bq of iodine 125. Twenty-six patients with primary colorectal cancer and 72 patients with recurrent colorectal cancer were examined. Using the gamma detecting probe, 78% of the patients had localization of the antibody in their tumor; this included 75% of primary tumor sites and 63% of all recurrent tumor sites; 9.2% of all tumor sites identified represented occult sites detected only with the gamma detecting probe. The overall sensitivity was 77% and a predictive value of a positive detection was 78%. A total of 30 occult sites in 26 patients were identified. In patients with recurrent cancer, the antibody study provided unique data that precluded resection in 10 patients, and in another eight patients it extended the potentially curative procedure

  4. A prospective analysis of long-term quality of life after permanent I-125 brachytherapy for localised prostate cancer

    International Nuclear Information System (INIS)

    Ash, Dan; Bottomley, David; Al-Qaisieh, Bashar; Carey, Brendan; Gould, Kath; Henry, Ann

    2007-01-01

    Background and purpose: To prospectively evaluate long-term urinary, bowel and sexual function after I-125 brachytherapy for localised prostate cancer using patient administered validated Quality of Life (QoL) instruments. Materials and methods: Between March 1995 and March 2004, 673 men underwent brachytherapy and recorded urinary symptoms prospectively using the International Prostate Symptom Score (IPSS). In addition, in a subgroup of 116 patients, the Expanded Prostate Cancer Index Composite (EPIC) was used to record QoL information on urinary, bowel and sexual function before treatment and at regular time intervals for at least two years. Results: Initially, there was a sharp rise in urinary symptoms which was most marked within the first three months. Scores then resolved slowly and returned to within one or two units of pre-treatment level at one year. Subsequently, there was no significant deterioration in urinary symptoms up to nine years following brachytherapy. Few had significant bowel symptoms. Sexual function deteriorated initially and then improved but failed to return to pre-treatment levels by two years. Patients requiring neo-adjuvant hormones experienced significantly more dysfunction. Conclusions: After an initial period of mild to moderate urinary symptoms prostate brachytherapy is well tolerated with relatively little deterioration in long-term quality of life. Long-term reduction in sexual function may be seen particularly in those requiring hormones

  5. Prostate biopsy after definitive treatment by interstitial iodine 125 implant or external beam radiation therapy

    International Nuclear Information System (INIS)

    Schellhammer, P.F.; el-Mahdi, A.M.; Higgins, E.M.; Schultheiss, T.E.; Ladaga, L.E.; Babb, T.J.

    1987-01-01

    The response to definitive radiation therapy of localized carcinoma of the prostate by iodine 125 implantation or external beam radiotherapy was monitored by examining specimens from biopsies performed after treatment. We analyzed 126 biopsy specimens obtained 18 months or more after treatment: 71 were obtained from 109 patients treated by iodine 125 and 55 from 197 patients treated by external beam radiotherapy. Thereafter, the disease status of these patients was examined at minimum 3-year intervals. No significant statistical difference was found between the negative specimen rates of the 2 treatment modalities: 46 of 71 (65 per cent) after iodine 125 implantation and 39 of 55 (71 per cent) after external beam radiotherapy were negative. To analyze the predictive value of biopsy results 103 patients whose prostatic examination results were normal at biopsy or who showed regression of tumor size and tumor induration after radiation were evaluated. The biopsy results from all patients were combined for analysis. Of 77 patients with negative biopsy specimens 16 (21 per cent) have had recurrent disease, compared to 17 of 26 (65 per cent) with positive biopsy specimens (p equals 0.00005). Of the 77 patients with negative biopsy specimens 7 (9 per cent) had local disease recurrence, compared to 12 of 26 (46 per cent) with a positive biopsy specimen (p equals 0.0001). The value of a positive specimen to predict failure remained significant with patients stratified by pre-treatment clinical stage and grade of the disease. Our results show that patients with positive specimens from the prostate who had been judged clinically by rectal examination to have responded to radiation therapy had a significantly increased incidence of local and distant failure compared to patients who had negative biopsy specimens

  6. Staff dose of hospitalization in the treatment of patients in ophthalmic brachytherapy with 125 I; Dosis al personal de hospitalizacion en el tratamiento de pacientes de braquiterapia oftalmica con I-125

    Energy Technology Data Exchange (ETDEWEB)

    Terron Leon, J. A.; Gomez Palacios, M.; Moreno Reyes, J. C.; Perales Molina, A.

    2013-07-01

    The objective of this work, therefore, has been the evaluation of the dose levels which nursing staff can receive in care for ophthalmic brachytherapy patients treated with 125 I from measurements made on the same, evaluating, in an experimental way, job security following the PR rules laid down for these treatments. (Author)

  7. A new human eye model for ophthalmic brachytherapy dosimetry

    International Nuclear Information System (INIS)

    Yoriyaz, H.; Sanchez, A.; Dos Santos, A.

    2005-01-01

    The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new model includes detailed description of internal structures that were not treated in previous works, allowing dose determination in different regions of the eye for a more adequate clinical analysis. Dose calculations were determined with the MCNP-4C Monte Carlo particle transport code running n parallel environment using PVM. The Amersham CKA4 ophthalmic applicator has been chosen and the depth dose distribution has been determined and compared to those provide by the manufacturer. The results have shown excellent agreement. Besides, absorbed dose values due to both 125 I seeds and 60 Co plaques were obtained for each one of the different structures which compose the eye model and can give relevant information in eventual clinical analyses. (authors)

  8. Dose rate constants for 125I, 103Pd, 192Ir and 169Yb brachytherapy sources: an EGS4 Monte Carlo study

    International Nuclear Information System (INIS)

    Mainegra, Ernesto; Capote, Roberto; Lopez, Ernesto

    1998-01-01

    An exhaustive revision of dosimetry data for 192 Ir, 125 I, 103 Pd and 169 Yb brachytherapy sources has been performed by means of the EGS4 simulation system. The DLC-136/PHOTX cross section library, water molecular form factors, bound Compton scattering and Doppler broadening of the Compton-scattered photon energy were considered in the calculations. The absorbed dose rate per unit contained activity in a medium at 1 cm in water and air-kerma strength per unit contained activity for each seed model were calculated, allowing the dose rate constant (DRC) Λ to be estimated. The influence of the calibration procedure on source strength for low-energy brachytherapy seeds is discussed. Conversion factors for 125 I and 103 Pd seeds to obtain the dose rate in liquid water from the dose rate measured in a solid water phantom with a detector calibrated for dose to water were calculated. A theoretical estimate of the DRC for a 103 Pd model 200 seed equal to 0.669±0.002 cGy h -1 U -1 is obtained. Comparison of obtained DRCs with measured and calculated published results shows agreement within 1.5% for 192 Ir, 169 Yb and 125 I sources. (author)

  9. Electroless Sliver-Plating Process in the Preparation of 103Pd-125I Hybrid Brachytherapy Seed Cores

    Directory of Open Access Journals (Sweden)

    LI Zhong-yong1,2;CHEN Bin-da1;Lv Xiao-zhou1;LU Jin-hui1;CUI Hai-ping1,2

    2014-02-01

    Full Text Available Electroless 103Pd plating and electroless Ag plating and chemical 125I depositing were took place on the surface of carbon rods in turn, which was a reliable method for the preparation of 103Pd-125I hybrid brachytherapy seed cores. 103Pd and 125I were deposited on the same substrate effectively through silver coating as a bridge. The process of electroless Ag plating was a novel and important step in the preparation of 103Pd-125I hybrid seed. In this work, the process of electroless Ag plating was studied using 0.5×3.0 mm carbon rods with palladium coating as substrate, silver-ammino complex as precursor, 110mAg as radioactive tracer, and hydrazine as reductant. The optimum conditions were AgNO3 2g/L,Na2EDTA 40 g/L,NH3•H2O 16.25%,H4N2•H2O 5‰,pH=10,t=60 min,and T=35 ℃. Sliver deposited on each carbon rod was uniform, and sliver-coating was white and smooth.

  10. Predictive factors for acute and late urinary toxicity after permanent interstitial brachytherapy in Japanese patients

    International Nuclear Information System (INIS)

    Tanimoto, Ryuta; Bekku, Kensuke; Katayama, Norihisa

    2013-01-01

    The objectives of this study were to describe the frequency of and to determine predictive factors associated with Radiation Therapy Oncology Group urinary toxicity in prostate brachytherapy patients. From January 2004 to April 2011, 466 consecutive Japanese patients underwent permanent iodine-125-seed brachytherapy (median follow up 48 months). International Prostate Symptom Score and Radiation Therapy Oncology Group toxicity data were prospectively collected. Prostate volume, International Prostate Symptom Score before and after brachytherapy, and postimplant analysis were examined for an association with urinary toxicity, defined as Radiation Therapy Oncology Group urinary toxicity of Grade 1 or higher. Logistic regression analysis was used to examine the factors associated with urinary toxicity. The rate of Radiation Therapy Oncology Group urinary toxicity grade 1 or higher at 1, 6, 12, 24, 36 and 48 months was 67%, 40%, 21%, 31%, 27% and 28%, respectively. Grade 2 or higher urinary toxicity was less than 1% at each time-point. International Prostate Symptom Score was highest at 3 months and returned to normal 12 months after brachytherapy. On multivariate analysis, patients with a larger prostate size, greater baseline International Prostate Symptom Score, higher prostate V100, higher prostate V150, higher prostate D90 and a greater number of seeds had more acute urinary toxicities at 1 month and 12 months after brachytherapy. On multivariate analysis, significant predictors for urinary toxicity at 1 month and 12 months were a greater baseline International Prostate Symptom Score and prostate V100. Most urinary symptoms are tolerated and resolved within 12 months after prostate brachytherapy. Acute and late urinary toxicity after brachytherapy is strongly related to the baseline International Prostate Symptom Score and prostate V100. (author)

  11. Salvage/Adjuvant Brachytherapy After Ophthalmic Artery Chemosurgery for Intraocular Retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Francis, Jasmine H., E-mail: francij1@mskcc.org [Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Barker, Christopher A.; Wolden, Suzanne L.; McCormick, Beryl; Segal, Kira; Cohen, Gil [Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Gobin, Y. Pierre; Marr, Brian P. [Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Weill-Cornell Medical College, New York-Presbyterian Hospital, New York, New York (United States); Brodie, Scott E. [Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Mount Sinai School of Medicine, New York, New York (United States); Dunkel, Ira J.; Abramson, David H. [Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Weill-Cornell Medical College, New York-Presbyterian Hospital, New York, New York (United States)

    2013-11-01

    Purpose: To evaluate the efficacy and toxicity of brachytherapy after ophthalmic artery chemosurgery (OAC) for retinoblastoma. Methods and Materials: This was a single-arm, retrospective study of 15 eyes in 15 patients treated with OAC followed by brachytherapy at (blinded institution) between May 1, 2006, and December 31, 2012, with a median 19 months' follow-up from plaque insertion. Outcome measurements included patient and ocular survival, visual function, and retinal toxicity measured by electroretinogram (ERG). Results: Brachytherapy was used as adjuvant treatment in 2 eyes and as salvage therapy in 13 eyes of which 12 had localized vitreous seeding. No patients developed metastasis or died of retinoblastoma. The Kaplan-Meier estimate of ocular survival was 79.4% (95% confidence interval 48.7%-92.8%) at 18 months. Three eyes were enucleated, and an additional 6 eyes developed out-of-target volume recurrences, which were controlled with additional treatments. Patients with an ocular complication had a mean interval between last OAC and plaque of 2.5 months (SD 2.3 months), which was statistically less (P=.045) than patients without ocular complication who had a mean interval between last OAC and plaque of 6.5 months (SD 4.4 months). ERG responses from pre- versus postplaque were unchanged or improved in more than half the eyes. Conclusions: Brachytherapy following OAC is effective, even in the presence of vitreous seeding; the majority of eyes maintained stable or improved retinal function following treatment, as assessed by ERG.

  12. Salvage/Adjuvant Brachytherapy After Ophthalmic Artery Chemosurgery for Intraocular Retinoblastoma

    International Nuclear Information System (INIS)

    Francis, Jasmine H.; Barker, Christopher A.; Wolden, Suzanne L.; McCormick, Beryl; Segal, Kira; Cohen, Gil; Gobin, Y. Pierre; Marr, Brian P.; Brodie, Scott E.; Dunkel, Ira J.; Abramson, David H.

    2013-01-01

    Purpose: To evaluate the efficacy and toxicity of brachytherapy after ophthalmic artery chemosurgery (OAC) for retinoblastoma. Methods and Materials: This was a single-arm, retrospective study of 15 eyes in 15 patients treated with OAC followed by brachytherapy at (blinded institution) between May 1, 2006, and December 31, 2012, with a median 19 months' follow-up from plaque insertion. Outcome measurements included patient and ocular survival, visual function, and retinal toxicity measured by electroretinogram (ERG). Results: Brachytherapy was used as adjuvant treatment in 2 eyes and as salvage therapy in 13 eyes of which 12 had localized vitreous seeding. No patients developed metastasis or died of retinoblastoma. The Kaplan-Meier estimate of ocular survival was 79.4% (95% confidence interval 48.7%-92.8%) at 18 months. Three eyes were enucleated, and an additional 6 eyes developed out-of-target volume recurrences, which were controlled with additional treatments. Patients with an ocular complication had a mean interval between last OAC and plaque of 2.5 months (SD 2.3 months), which was statistically less (P=.045) than patients without ocular complication who had a mean interval between last OAC and plaque of 6.5 months (SD 4.4 months). ERG responses from pre- versus postplaque were unchanged or improved in more than half the eyes. Conclusions: Brachytherapy following OAC is effective, even in the presence of vitreous seeding; the majority of eyes maintained stable or improved retinal function following treatment, as assessed by ERG

  13. CT-stereotactic interstitial Curie-therapy using iodine-125 seeds in inoperable brain tumours

    International Nuclear Information System (INIS)

    Mundinger, F.

    1985-01-01

    Iodine-125 seeds are a new radio-drug featuring favourable physical, biological and radiation protection characteristics and available for interstitial (local) irradiation (Curie-therapy) of non-resectable brain tumours as such (cerebral tumours) or of tumours of the interior of the neuro-cranium (extracerebral tumours). Emitters are inserted right into the tumour or tumour recurrence by means of computerized-tomography stereotaxy either permanently or temporarily with dose release being largely restricted to the tumour and the surrounding brain tissue being spared. (orig.) [de

  14. Development of a homologous iodine-125 labelled progesterone radioimmunoassay system

    International Nuclear Information System (INIS)

    Elbanna, I.M.; El-Asrag, H.A.; Gado, M.S.; Gamal, M.H.

    1985-01-01

    Detailed procedure description of an iodinated progesterone radioimmunoassay system development is reported. Immunization regime with progesterone 11 α-hemisuccinate: BSA gave 1:6000 antibody titre within a period of 6 months. Minimal amount of the immunogen was spent to obtain a stock of the antiserum. Conjugation of progesterone 11 α-hemisuccinate to tyrosine methyl ester using the isobutyl-chloroformate reaction gave a product with less patch to patch variations in tracer characteristics. At home radioiodination with 125 I reduced the expenses drastically and resulted in extended tracer shelf life (up to 3 months). The use of the second antibody method of separating bound from free hormone proved to be more convenient and brought the progesterone radioimmunoassay system to routine work

  15. Towards clinical application of RayStretch for heterogeneity corrections in LDR permanent 125I prostate brachytherapy.

    Science.gov (United States)

    Hueso-González, Fernando; Ballester, Facundo; Perez-Calatayud, Jose; Siebert, Frank-André; Vijande, Javier

    RayStretch is a simple algorithm proposed for heterogeneity corrections in low-dose-rate brachytherapy. It is built on top of TG-43 consensus data, and it has been validated with Monte Carlo (MC) simulations. In this study, we take a real clinical prostate implant with 71 125 I seeds as reference and we apply RayStretch to analyze its performance in worst-case scenarios. To do so, we design two cases where large calcifications are located in the prostate lobules. RayStretch resilience under various calcification density values is also explored. Comparisons against MC calculations are performed. Dose-volume histogram-related parameters like prostate D 90 , rectum D 2cc , or urethra D 10 obtained with RayStretch agree within a few percent with the detailed MC results for all cases considered. The robustness and compatibility of RayStretch with commercial treatment planning systems indicate its applicability in clinical practice for dosimetric corrections in prostate calcifications. Its use during intraoperative ultrasound planning is foreseen. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  16. Alternative labelling of the cocaine analogue isomers α-CIT and β-CIT by direct iodination with no-carrier-added Na125I

    International Nuclear Information System (INIS)

    Mueller, L.; Foged, C.; Halldin, C.; Swahn, C.-G.

    1994-01-01

    An alternative labelling of the cocaine analogue isomers α-CIT and β-CIT with no-carrier-added 125 I by direct iodination of 2α- and 2β-carbomethoxy-3β-phenyltropane with Na 125 I/sulfuric acid/nitric acid/acetic acid and peracetic acid under different reaction conditions, is described. The maximum radiolabelling yield obtained with the two isomers was 48% for [ 125 I]α-CIT and 28% for [ 125 I]β-CIT. (author)

  17. Spectral CT evaluation of interstitial brachytherapy in pancreatic carcinoma xenografts: preliminary animal experience

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Shudong [Jiangsu University, Department of Radiology, The Affiliated Renmin Hospital, Zhenjiang, Jiangsu (China); Shanghai Jiao tong University, School of Medicine, Department of Radiology, Ruijin Hospital, Shanghai (China); Huang, Wei; Song, Qi; Lin, Xiaozhu; Wang, Zhongmin; Chen, Kemin [Shanghai Jiao tong University, School of Medicine, Department of Radiology, Ruijin Hospital, Shanghai (China); Chen, Yerong [Jiangsu University, Department of Radiology, The Affiliated Renmin Hospital, Zhenjiang, Jiangsu (China)

    2014-09-15

    We sought to evaluate the capability of spectral CT to detect the therapeutic response to {sup 125}I interstitial brachytherapy in a pancreatic carcinoma xenograft nude mouse model. Twenty mice bearing SWl990 human pancreatic cancer cell xenografts were randomly separated into two groups: experimental (n = 10; 1.0 mCi) and control (n = 10; 0 mCi). After a two-week treatment, spectral CT was performed. Contrast-to-noise ratio (CNR) and iodine concentration (IC) in the lesions were measured and normalized to the muscle tissue, and nIC CD31 immunohistochemistry was used to measure microvessel density (MVD). The relationships between the nIC and MVD of the tumours were analysed. The nIC of the experimental group was significantly lower than that of the control group during the multiphase examination. A significant difference in the MVD was observed between the two groups (P <0.001). The nIC values of the three-phase scans have a certain positive correlation with MVD (r = 0.57, p < 0.0001; r = 0.48, p = 0.002; r = 0.63, p = 0.0017 in the 10, 25, and 60 s phase, respectively). Spectral CT can be a useful non-invasive imaging modality in evaluating the therapeutic effect of {sup 125}I interstitial brachytherapy to a pancreatic carcinoma. (orig.)

  18. On the use of Kodak CR film for quality assurance of needle loading in I-125 seed prostate brachytherapy.

    Science.gov (United States)

    Fog, L S; Nicholls, R; van Doom, T

    2007-09-01

    Low dose rate brachytherapy using implanted I-125 seeds as a monotherapy for prostate cancer is now in use in many hospitals. In contrast to fractionated brachytherapy treatments, where the effect of incorrect positioning of the source in one treatment fraction can be diminished by correcting the position in subsequent fractions, the I-125 seed implant is permanent, making correct positioning of the seeds in the prostate essential. The seeds are inserted into the prostate using needles. Correct configuration of seeds in the needles is essential in order to deliver the planned treatment. A comparison of an autoradiograph obtained by exposing film to the seed-loaded needles with the patient treatment plan is a valuable quality assurance tool. However, the time required to sufficiently expose Kodak XOMAT V film, currently used in this department is significant. This technical note presents the use of Kodak CR film for acquisition of the radiograph. The digital radiograph can be acquired significantly faster, has superior signal-to-noise ratio and contrast and has the usual benefits of digital film, e.g. a processing time which is shorter than that required for non-digital film, the possibility of image manipulation, possibility of paper printing and electronic storage.

  19. Immunospecific red cell binding of iodine 125-labeled immunoglobulin G erythrocyte autoantibodies

    International Nuclear Information System (INIS)

    Masouredis, S.P.; Branks, M.J.; Garratty, G.; Victoria, E.J.

    1987-01-01

    The primary interaction of autoantibodies with red cells has been studied by using labeled autoantibodies. Immunoglobulin G red cell autoantibodies obtained from IgG antiglobulin-positive normal blood donors were labeled with radioactive iodine and compared with alloanti-D with respect to their properties and binding behavior. Iodine 125 -labeled IgG autoantibody migrated as a single homogeneous peak with the same relative mobility as human IgG on sodium dodecyl sulfate-polyacrylamide gel electrophoresis. The isoelectric focusing pattern of labeled autoantibodies varied from donor to donor but was similar to that of alloanti-D, consisting of multiple IgG populations with isoelectric points in the neutral to alkaline range. 125 I-autoantibody bound to all human red cells of common Rh phenotypes. Evidence for immunospecific antibody binding of the labeled autoantibody was based on variation in equilibrium binding to nonhuman and human red cells of common and rare phenotypes, enhanced binding after red cell protease modification, antiglobulin reactivity of cell-bound IgG comparable to that of cell-bound anti-D, and saturation binding in autoantibody excess. Scatchard analysis of two 125 I-autoantibody preparations yielded site numbers of 41,500 and 53,300 with equilibrium constants of 3.7 and 2.1 X 10(8) L X mol-1. Dog, rabbit, rhesus monkey, and baboon red cells were antigen(s) negative by quantitative adsorption studies adsorbing less than 3% of the labeled autoantibody. Reduced ability of rare human D--red blood cells to adsorb the autoantibody and identification of donor autoantibodies that bind to Rh null red blood cells indicated that eluates contained multiple antibody populations of complex specificities in contrast to anti-D, which consists of a monospecific antibody population. Another difference is that less than 70% of the autoantibody IgG was adsorbed by maximum binding red blood cells as compared with greater than 85% for alloanti-D

  20. Synthesis and biologic studies of iodinated ({sup 125}I/{sup 127}I) ethidium

    Energy Technology Data Exchange (ETDEWEB)

    Ho Nanhui; Tumeh, Paul C.; Kassis, Amin I. E-mail: amin_kassis@hms.harvard.edu

    2001-11-01

    An iodinated ({sup 125}I/{sup 127}I) ethidium derivative (3,8-diamino-5-[6'-(p-iodobenzoylamino)-4'-azahexyl]-6 -phenylphenanthridinium chloride hydrochloride) was synthesized and characterized. The labeling yield of the {sup 125}I-labeled derivative was 75% for carrier-free {sup 125}I, with a radiochemical purity of 95%. The incubation of iodoethidium with calf thymus DNA resulted in a substantial enhancement of fluorescence yield, indicating the intercalation of this compound into DNA. In the presence of iodoethidium, the nuclei of methanol-treated mammalian cells fluoresced, while those of viable cells did not (since the plasma membrane is impermeable to iodoethidium). When viable cells were incubated with the reduced form of the derivative, {sup 125}I/{sup 127}I-dihydroethidium traversed the plasma membrane, was oxidized in the cytoplasm, and intercalated into nuclear DNA. Finally, we tested the hypothesis that larger malignant solid tumors, containing a relatively greater percentage of degenerating permeable cells, can be targeted with {sup 125}I-ethidium. In-vivo studies demonstrated a small but positive correlation (R = 0.72) between tumor volume and the uptake of the derivative. Because of the ubiquitous presence of abnormal permeable cells and necrosis in tumors, our results support the belief that radiolabeled DNA-intercalating or DNA-binding molecules may be of diagnostic and therapeutic value for a variety of solid tumors in humans.

  1. Gene amplification in Chinese hamster embryo cells by the decay of incorporated iodine-125

    International Nuclear Information System (INIS)

    Luecke-Huhle, Christine; Ehrfeld, Angelika; Rau, Waltraud

    1988-01-01

    Simian Virus 40-transformed Chinese hamster embryo cells (Co631) contain 5 viral copies integrated per cell genome. These SV40 sequences were used as an endogenous indicator gene to study response of mammalian cells to radiation at gene level. Cells were internally irradiated by Auger electrons emitted by Iodine-125 which was incorporated in cell DNA in form of 5-[ 125 I] iododeoxyuridine ( 125 IdU). An increase in gene copy number was measured using dispersed cell blotting and Southern analysis in combination with highly sensitive DNA hybridization. A 13-fold amplification of the SV40 sequences and a 2-fold amplification of two cellular oncogenes of the ras family were found. Other cellular genes, like the α-actin gene, are not amplified and no variation in gene copy number was observed after incubation of cells with cold IdU. Thus, specific gene amplification seems to be the consequence of radiation-induced DNA damage and the resulting cell cycle arrest. (author)

  2. Long term outcome and side effects in patients receiving low-dose I125 brachytherapy: a retrospective analysis

    Directory of Open Access Journals (Sweden)

    Pieter Logghe

    Full Text Available ABSTRACT Objectives: To retrospectively evaluate the disease free survival (DFS, disease specific survival (DSS,overall survival (OS and side effects in patients who received low-dose rate (LDR brachytherapy with I125 stranded seeds. Materials and methods: Between july 2003 and august 2012, 274 patients with organ confined prostate cancer were treated with permanent I125 brachytherapy. The median follow-up, age and pretreatment prostate specific antigen (iPSA was 84 months (12-120, 67 years (50-83 and 7.8 ng/mL (1.14-38, respectively. Median Gleason score was 6 (3-9. 219 patients (80% had stage cT1c, 42 patients (15.3% had stage cT2a, 3 (1.1% had stage cT2b and 3 (1.1% had stage cT2c. The median D90 was 154.3 Gy (102.7-190.2. Results: DSS was 98.5%.OS was 93.5%. 13 patients (4.7% developed systemic disease, 7 patients (2.55% had local progression. In 139 low risk patients, the 5 year biochemical freedom from failure rate (BFFF was 85% and 9 patients (6.4% developed clinical progression. In the intermediate risk group, the 5 year BFFF rate was 70% and 5 patients (7.1% developed clinical progression. Median nPSA in patients with biochemical relapse was 1.58 ng/mL (0.21 – 10.46, median nPSA in patients in remission was 0.51 ng/mL (0.01 – 8.5. Patients attaining a low PSA nadir had a significant higher BFFF (p<0.05. Median D90 in patients with biochemical relapse was 87.2 Gy (51 – 143,1. Patients receiving a high D90 had a significant higher BFFF (p<0.05. Conclusion: In a well selected patient population, LDR brachytherapy offers excellent outcomes. Reaching a low PSA nadir and attaining high D90 values are significant predictors for a higher DFS.

  3. I-125 seed dose estimates in heterogeneous phantom

    International Nuclear Information System (INIS)

    Branco, Isabela S.L.; Antunes, Paula C.G.; Cavalieri, Tassio A.; Moura, Eduardo S.; Zeituni, Carlos A.; Yoriyaz, Helio

    2015-01-01

    Brachytherapy plays an important role in the healing process involving tumors in a variety of diseases. Several studies are currently conducted to examine the heterogeneity effects of different tissues and organs in brachytherapy clinical situations and a great effort has been made to incorporate new methodologies to estimate doses with greater accuracy. The objective of this study is to contribute to the assessment of heterogeneous effects on dose due to I-125 brachytherapy source in the presence of different materials with different densities and chemical compositions. The study was performed in heterogeneous phantoms using materials that simulate human tissues. Among these is quoted: breast, fat, muscle, lungs (exhaled and inhaled) and bones with different densities. Monte Carlo simulations for dose calculation in these phantoms were held and subsequently validated. The model 6711 I-125 seed was considered because it is widely used as a brachytherapy permanent implant and the one used in clinics and hospitals in Brazil. Thermoluminescent dosimeters TLD-700 (LiF: Mg, Ti) were simulated for dose assess. Several tissue configurations and positioning of I-125 sources were studied by simulations for future dose measurements. The methodology of this study so far shall be suitable for accurate dosimetric evaluation for different types of brachytherapy treatments, contributing to brachytherapy planning systems complementation allowing a better assessment of the dose actually delivered to the patient. (author)

  4. I-125 seed dose estimates in heterogeneous phantom

    Energy Technology Data Exchange (ETDEWEB)

    Branco, Isabela S.L.; Antunes, Paula C.G.; Cavalieri, Tassio A.; Moura, Eduardo S.; Zeituni, Carlos A.; Yoriyaz, Helio, E-mail: isabela.slbranco@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Brachytherapy plays an important role in the healing process involving tumors in a variety of diseases. Several studies are currently conducted to examine the heterogeneity effects of different tissues and organs in brachytherapy clinical situations and a great effort has been made to incorporate new methodologies to estimate doses with greater accuracy. The objective of this study is to contribute to the assessment of heterogeneous effects on dose due to I-125 brachytherapy source in the presence of different materials with different densities and chemical compositions. The study was performed in heterogeneous phantoms using materials that simulate human tissues. Among these is quoted: breast, fat, muscle, lungs (exhaled and inhaled) and bones with different densities. Monte Carlo simulations for dose calculation in these phantoms were held and subsequently validated. The model 6711 I-125 seed was considered because it is widely used as a brachytherapy permanent implant and the one used in clinics and hospitals in Brazil. Thermoluminescent dosimeters TLD-700 (LiF: Mg, Ti) were simulated for dose assess. Several tissue configurations and positioning of I-125 sources were studied by simulations for future dose measurements. The methodology of this study so far shall be suitable for accurate dosimetric evaluation for different types of brachytherapy treatments, contributing to brachytherapy planning systems complementation allowing a better assessment of the dose actually delivered to the patient. (author)

  5. Iodination and stability of somatostatin analogues: comparison of iodination techniques. A practical overview.

    Science.gov (United States)

    de Blois, Erik; Chan, Ho Sze; Breeman, Wouter A P

    2012-01-01

    For iodination ((125/127)I) of tyrosine-containing peptides, chloramin-T, Pre-Coated Iodo-Gen(®) tubes and Iodo-Beads(®) (Pierce) are commonly used for in vitro radioligand investigations and there have been reliant vendors hereof for decades. However, commercial availability of these radio-iodinated peptides is decreasing. For continuation of our research in this field we investigated and optimized (radio-)iodination of somatostatin analogues. In literature, radioiodination using here described somatostatin analogues and iodination techniques are described separately. Here we present an overview, including High Performance Liquid Chromatography (HPLC) separation and characterisation by mass spectrometry, to obtain mono- and di-iodinated analogues. Reaction kinetics of (125/127)I iodinated somatostatin analogues were investigated as function of reaction time and concentration of reactants, including somatostatin analogues, iodine and oxidizing agent. To our knowledge, for the here described somatostatin analogues, no (127)I iodination and optimization are described. (Radio-)iodinated somatostatin analogues could be preserved with a >90% radiochemical purity for 1 month after reversed phase HPLC-purification.

  6. Preparation of high-quality iodine-125-labelled pituitary human follicle-stimulating hormone (hFSH) for radioimmunoassay

    International Nuclear Information System (INIS)

    Pinto, H.; Lerario, A.C.; Toledo e Souza, I.T. de; Wajchenberg, B.L.; Mattar, E.; Pieroni, R.R.

    1977-01-01

    A method is described for the enzymatic radioiodination of human follice-stimulating hormone (hFSH) by a system consisting of lactoperoxidase, hydrogen peroxide and Na 125 I. It is compared with the chloramine-T modified technique. A satisfactory specific activity of the labelled hormone is obtained with the enzymatic iodination, with much greater immunoreactivity and stability than with chloramine-T [pt

  7. A comparison study on various low energy sources in interstitial prostate brachytherapy.

    Science.gov (United States)

    Bakhshabadi, Mahdi; Ghorbani, Mahdi; Khosroabadi, Mohsen; Knaup, Courtney; Meigooni, Ali S

    2016-02-01

    Low energy sources are routinely used in prostate brachytherapy. (125)I is one of the most commonly used sources. Low energy (131)Cs source was introduced recently as a brachytherapy source. The aim of this study is to compare dose distributions of (125)I, (103)Pd, and (131)Cs sources in interstitial brachytherapy of prostate. ProstaSeed (125)I brachytherapy source was simulated using MCNPX Monte Carlo code. Additionally, two hypothetical sources of (103)Pd and (131)Cs were simulated with the same geometry as the ProstaSeed (125)I source, while having their specific emitted gamma spectra. These brachytherapy sources were simulated with distribution of forty-eight seeds in a phantom including prostate. The prostate was considered as a sphere with radius of 1.5 cm. Absolute and relative dose rates were obtained in various distances from the source along the transverse and longitudinal axes inside and outside the tumor. Furthermore, isodose curves were plotted around the sources. Analyzing the initial dose profiles for various sources indicated that with the same time duration and air kerma strength, (131)Cs delivers higher dose to tumor. However, relative dose rate inside the tumor is higher and outside the tumor is lower for the (103)Pd source. The higher initial absolute dose in cGy/(h.U) of (131)Cs brachytherapy source is an advantage of this source over the others. The higher relative dose inside the tumor and lower relative dose outside the tumor for the (103)Pd source are advantages of this later brachytherapy source. Based on the total dose the (125)I source has advantage over the others due to its longer half-life.

  8. The incidence of radioepidermitis and the dose-response relationship in parotid gland cancer patients treated with 125I seed brachytherapy. Incidence of radioepidermitis and the dose-response relationship

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Ming-Hui; Zheng, Lei; Gao, Hong; Zhang, Jie; Liu, Shu-ming; Huang, Ming-wei; Shi, Yan [Peking University School and Hospital of Stomatology, Department of Oral and Maxillofacial Surgery, Beijing (China); Zhang, Jian-Guo [Peking University School and Hospital of Stomatology, Department of Oral and Maxillofacial Surgery, Beijing (China); Fujian Provincial Hospital, Fujian (China)

    2014-09-09

    We studied the incidence and dose-response relationship of radioepidermitis in parotid gland carcinoma patients treated with [{sup 125}I] seed brachytherapy in the hopes of designing an optimized pre-implant treatment plan that would reduce the incidence and severity of radioepidermitis in patients receiving this therapy. Between January 2007 and May 2010, 100 parotid gland cancer patients were treated postoperatively with [{sup 125}I] seed brachytherapy. The matched peripheral dose (MPD) was 80-140 Gy, and [{sup 125}I] seed activity was 0.7-0.8 mCi. The mean dose delivered to the skin was calculated in the post-implant CT on day 0 following implantation. Grades of acute and late dermatitis were evaluated at 2, 6, 12, and 18 months post-implantation. Most patients experienced grade 0-2 acute and late skin side effects (86 and 97 %, respectively), though a small subset developed severe complications. Most grade 1-3 effects resolved within 6 months of implantation, though some grade 1-3 effects and all grade 4 effects remained unchanged throughout the 18-month follow-up period. Grade 3 and 4 effects were most prominent (75 and 25 %, respectively) with doses of 110-140 Gy; doses higher than 140 Gy produced only grade 4 effects. [{sup 125}I] seed brachytherapy produced acceptable levels of acute and late radioepidermitis with a good clinical outcome. A mean dose under 100 Gy delivered to the skin was safe, though doses of 110-140 Gy should be given with caution and extra monitoring; doses greater than 140 Gy are dangerous and likely to produce grade 4-5 effects. (orig.) [German] Wir untersuchten die Inzidenz und die Dosis-Wirkung-Beziehung bei Patienten mit Ohrspeicheldruesenkrebs, die mit [{sup 125}I]-Seed-Brachytherapie behandelt wurden, in der Hoffnung, eine optimierte praeimplantologische Behandlung zu entwickeln, welche die Inzidenz und Schwere der Radioepidermitis bei Patienten, die diese Therapie erhalten haben, reduziert. Zwischen Januar 2007 und Mai 2010

  9. Iodine 125 prostate brachytherapy: prognostic factors for long-term urinary, digestive and sexual toxicities;Curietherapie de prostate par iode 125: facteurs pronostiques de longue duree de toxicite urinaire, digestive et sexuelle

    Energy Technology Data Exchange (ETDEWEB)

    Doyen, J.; Mohammed Ali, A.; Ginot, A.; Ferre, M.; Castelli, J.; Hannoun-Levi, J.M. [Centre Antoine-Lacassagne, Dept. de Radiotherapie Oncologique, 06 - Nice (France); Chamorey, E. [Centre Antoine-Lacassagne, Unite de Statistiques Medicales, 06 - Nice (France); Mohammed Ali, A. [Faculte de Medecine, SOHAG (Egypt); Quintens, H.; Amiel, J. [CHU Pasteur, Service d' Urologie, 06 - Nice (France)

    2009-12-15

    Purpose For patients with good urinary function and presenting with a low risk prostate cancer, prostate brachytherapy using iodine implants represents one of the techniques of reference. This retrospective analysis investigates urinary (U), digestive (D) and sexual (S) toxicities and their prognostic factors of duration. Material and methods From August 2000 to November 2007, 176 patients presenting with prostate adenocarcinoma underwent interstitial brachytherapy. Urinary, digestive and sexual toxicities were classified according to Common toxicities criteria for adverse events, version 3.0 (C.T.C.A.E. V 3.0). For each toxicity (U, D, S), the number of complications U (dysuria, nicturia), D (proctitis, diarrhea) and S (sexual dysfunction, loss of libido) was listed and analyzed according to criteria related to the patient, implant, dosimetric data and characteristics of the toxicity. Prognostic factors identified in univariate analysis (U.V.A.) (Log Rank) were further analyzed in multivariate analysis (M.V.A.) (Cox model). Results With a median follow-up of 26 months (1-87), 147 patients (83.5 %) presented urinary toxicities. Among them, 29.5 % (86 patients) and 2.4 % (seven patients) presented grade 2 and 3 U toxicity respectively. In U.V.A., urinary grade toxicity greater than or equal to 2 (p = 0.037), the presence of initial U symptoms (p = 0.027) and more than two urinary toxicities (p 0.00032) were recognized as prognostic factors. The number of U toxicities was the only prognostic factor in M.V.A. (p = 0.04). D toxicity accounted for 40.6 % (71 patients). Among them, 3 % (six patients) were grade 2. None were grade 3. Two factors were identified as prognostic factors either in U.V.A. and M.V.A.: the number of D toxicities greater than or equal to 2 (univariate analysis: p = 0,00129, multivariate analysis: p = 0,002) and age less than or equal to 65 years (univariate analysis: p = 0,004, multivariate analysis: p 0,007). Eighty-three patients (47

  10. Procedure for determination of the decontamination of piping in the production of iodine-125 seeds; Procedimento para determinacao da descontaminacao de tubulacoes, na producao de sementes de iodo-125

    Energy Technology Data Exchange (ETDEWEB)

    Moura, J.A.; Moura, E.S.; Sprenger, F.E.; Nagatomi, H.R.; Zeituni, C.A.; Feher, A.; Manzoli, J.E.; Souza, C.D.; Rostelato, M.E.C.M., E-mail: elisaros@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    Iodine-125 seeds are radioactive sources used in the prostate cancer treatment. This work objective was to determine the necessary conditions and procedures for decontamination of liquid transfer tubes when a radioactive material leakage occurs during the process of seed quality control

  11. Prediction of PSA bounce after permanent prostate brachytherapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Kanai, Kunimitsu; Nakashima, Jun; Sugawara, Akitomo

    2009-01-01

    We aimed to calculate the frequency and features of the development of a prostate-specific antigen (PSA) bounce after prostate brachytherapy alone, to correlate the bounce with clinical and dosimetric factors and to identify factors that predict PSA bounce. PSA bounce was evaluated in 86 patients with T1-T2 prostate cancer who underwent radioactive seed implantation using iodine-125 (I-125) without hormonal therapy or external-beam radiation therapy (EBRT) from September 2004 to December 2007. A PSA bounce was defined as a rise of at least 0.4 ng/ml greater than a previous PSA level with a subsequent decline equal to, or less than, the initial nadir. Calculated by the Kaplan-Meier method, the incidence of PSA bounce at a 2-year follow-up was 26%. Median time to the PSA bounce was 15 months. Univariate analysis demonstrated that age, dose received by 90% of the prostate gland (D90), volume of gland receiving 100% of the prescribed dose (V100), and V150 were significantly associated with the PSA bounce, while pretreatment PSA level, Gleason score, pretreatment prostate volume, clinical T stage, and V200 were not. In multivariate analysis, age 67 years or less and D90 more than 180 Gy were identified as independent factors for predicting the PSA bounce (P<0.05). PSA bounce is not a rare phenomenon after prostate brachytherapy. It is more common in younger patients and patients receiving higher doses of radiation. (author)

  12. Preparation of iodine-125-labeled iothalamate for renal clearance measurements

    International Nuclear Information System (INIS)

    Rao, S.A.; Herold, T.J.; Dewanjee, M.K.

    1983-01-01

    Iothalamate, a derivative of benzoic acid, is used as a contrast medium for renal function studies, particularly for measurement of glomerular filtration rate. Its chemical composition and clearance properties are similar to those of diatrizoate. The structural differences between these groups of iodinated benzoic acid derivatives are dependent on the groups attached at the 3- and 5-positions of 2,4,6-tri-iodobenzoic acid. The renal clearance of sodium iothalamate in humans closely approximates that of inulin, and it is used as a replacement for inulin in determining glomerular filtration rate. /sup 125/I-labeled iothalamate sodium can be prepared by the exchange-labeling method at pH 4.0. Iothalamate must first be isolated from the contrast medium preparation and purified before radioiodination. After radioiodination, the product is purified by means of precipitation and is then converted to the sodium salt

  13. 125Iodine labeling of β-hexosaminidase A without modifying its properties

    International Nuclear Information System (INIS)

    Kusiak, J.W.; Barranger, J.A.

    1979-01-01

    Human placental β-hexosaminidase A was labeled with 125 iodine to high specific activity with the retention of conformational integrity as judged by the retention of enzymatic activity. The oligosaccharide structure also appeared to be intact since the labeled enzyme was cleared from the circulation of the rat with a half-life identical to that of the unlabeled enzyme and an excess of unlabeled enzyme effectively blocked the clearance of the labelled form. Furthermore, the pattern of inhibition of clearance of the native and labeled enzymes by asialofetuin and mannans was identical. The useful and mild procedure for labeling enzymes may be of general importance in the preparation of enzymes for metabolic studies in normal animals and animal models of genetic lysosomal storage disorders. (Auth.)

  14. Study of dosimetric parameters for iodine-125 brachytherapy sources development from IPEN-CNEN/SP using Monte Carlo method

    International Nuclear Information System (INIS)

    Oliveira, Tiago Batista de

    2016-01-01

    Expectations of the World Health Organization for the year 2030 are that the number of cancer deaths is approximately 13.2 million, reflecting the high proportion of this disease in global health issue. With respect to prostate cancer, according to the National Cancer Institute, the number of cases diagnosed worldwide in 2012 was approximately 1.1 million, while in Brazil the data demonstrated the incidence of 68,000 new cases. The treatment of cancer can be performed with surgery (prostatectomy) or radiation therapy. Among radiotherapy, we can highlight the brachytherapy technique, which consists in the introduction of small radioactive sources (seeds) within the prostate, which is delivered a high dose value in the treatment volume and low dose in the surrounding tissues. In Brazil, the medical profession estimates a demand of approximately 8000 seeds / month, and the unit cost of each seed at least US $ 26.00. The AAPM protocol TG-43 recommend the dose-rate constant, radial dose function and anisotropy function for dosimetric analysis LDR brachytherapy seeds. In this work, Monte Carlo simulations were performed in order to assess the dosimetric parameters of the OncoSeed-6711, manufactured by Oncura-GEHealthcare, and a seed developed by Radiation Technology Center, using the MCNP5 code. A 6711 seed, an IPEN seed and the 30 x 30 x 30cm 3 phantom filled with water were modeled to simulate the dose distribution. The 6711 seed parameters were compared with literature, and the results presented relative error less than 0.1% for Λ. In comparison with the 6711 seed, the IPEN model seed dosimetric parameters were similar, account the statistical uncertainty. (author)

  15. Chemical and biological consequences of the radioactive decay of iodine-125 in plasmid DNA

    International Nuclear Information System (INIS)

    Linz, U.

    1983-09-01

    The consequences of the decay of iodine-125 incorporated into DNA were studied on a molecular basis. Doubly ( 14 C and 125 I) labelled 5-iodo-2'-deoxycytidine 5'-triphosphate (IdCTP) was synthesized and incorporated enzymatically into the SalI-cutting site of the plasmid pBR 322. Part of the radioiodinated DNA was treated with T4-DNA ligase in order to restore the circular structure of the native plasmid molecule. After 4 months of storage under various conditions the stable end products were analyzed by radio GC, radio HPLC and electron microscopy. The experiments were not only carried out with doubly-labelled DNA but also with solutions of 14 C-labelled DNA containing Na 125 I as internal radiation source. The results clearly indicate that radiolysis alone causes only minor damage. Transmutation of the covalently bound iodine, on the other hand, leads to complete destruction of the labelled nucleotide, giving rise to 14 CO 2 and 14 CO as main products. The production of 14 CO 2 which originates from both the base as well as the sugar component shows a strong solvent effect. The electron microscopy analysis of the DNA reveals that the local effects are always connected with at least one double strand break directly at the site of decay. In addition, one finds DNA double strand breaks in areas which are hundreds of base pairs apart from that site. Under certain circumstances most of the DNA molecules exhibit up to 10 breaks. A comparison between ligase-treated and untreated DNA shows that the configuration of the DNA and the position of the labelled nucleotide play in important role in the extent of the overall damage. It could be demonstrated that there is a linear correlation between gaseous fragmentation products and the number of double strand breaks. (orig./MG) [de

  16. A comparison study on various low energy sources in interstitial prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Mahdi Bakhshabadi

    2016-02-01

    Full Text Available Purpose: Low energy sources are routinely used in prostate brachytherapy. 125 I is one of the most commonly used sources. Low energy 131 Cs source was introduced recently as a brachytherapy source. The aim of this study is to compare dose distributions of 125 I, 103 Pd, and 131 Cs sources in interstitial brachytherapy of prostate. Material and methods: ProstaSeed 125 I brachytherapy source was simulated using MCNPX Monte Carlo code. Additionally, two hypothetical sources of 103 Pd and 131 Cs were simulated with the same geometry as the ProstaSeed 125 I source, while having their specific emitted gamma spectra. These brachytherapy sources were simulated with distribution of forty-eight seeds in a phantom including prostate. The prostate was considered as a sphere with radius of 1.5 cm. Absolute and relative dose rates were obtained in various distances from the source along the transverse and longitudinal axes inside and outside the tumor. Furthermore, isodose curves were plotted around the sources. Results : Analyzing the initial dose profiles for various sources indicated that with the same time duration and air kerma strength, 131 Cs delivers higher dose to tumor. However, relative dose rate inside the tumor is higher and outside the tumor is lower for the 103 Pd source. Conclusions : The higher initial absolute dose in cGy/(h.U of 131 Cs brachytherapy source is an advantage of this source over the others. The higher relative dose inside the tumor and lower relative dose outside the tumor for the 103 Pd source are advantages of this later brachytherapy source. Based on the total dose the 125 I source has advantage over the others due to its longer half-life.

  17. Exposure dose estimation of nursing personnel and visitors following "1"2"5I brachytherapy

    International Nuclear Information System (INIS)

    Nakazato, Kazuhisa; Kikuchi, Hirosumi; Hotta, Harumi; Nishizawa, Kunihide

    2007-01-01

    An automated access management system to the controlled sickrooms for "1"2"5I brachytherapy was developed. The system consists of access control and video surveillance units. The patients implanted "1"2"5I seeds were isolated for about 20 h after surgery in the controlled sickrooms. The maximum doses and dose rates of the nurses and visitors were estimated by using the legal upper limit activity of 1,300 MBq, the measured longest staying time, and the shortest distance between the patients and individuals. Video analysis revealed activities of the nurses, patients, and visitors in the controlled sickroom, and relationships between the access frequency and staying time. The nurses' measured doses ranged from 1 to 3 μSv, and averaged 1.6 μSv. The nurses' maximum dose and dose rate were 16 μSv and 5.6 nSv·h"-"1·MBq"-"1. The visitors' maximum dose and dose rate were 6 μSv and 2.6 nSv·h"-"1·MBq"-"1. The nurses and visitors' exposure doses per patient were estimated to be negligible compared with the annual limit of the public. (author)

  18. Effect of improved TLD dosimetry on the determination of dose rate constants for 125I and 103Pd brachytherapy seeds

    International Nuclear Information System (INIS)

    Rodriguez, M.; Rogers, D. W. O.

    2014-01-01

    Purpose: To more accurately account for the relative intrinsic energy dependence and relative absorbed-dose energy dependence of TLDs when used to measure dose rate constants (DRCs) for 125 I and 103 Pd brachytherapy seeds, to thereby establish revised “measured values” for all seeds and compare the revised values with Monte Carlo and consensus values. Methods: The relative absorbed-dose energy dependence, f rel , for TLDs and the phantom correction, P phant , are calculated for 125 I and 103 Pd seeds using the EGSnrc BrachyDose and DOSXYZnrc codes. The original energy dependence and phantom corrections applied to DRC measurements are replaced by calculated (f rel ) −1 and P phant values for 24 different seed models. By comparing the modified measured DRCs to the MC values, an appropriate relative intrinsic energy dependence, k bq rel , is determined. The new P phant values and relative absorbed-dose sensitivities, S AD rel , calculated as the product of (f rel ) −1 and (k bq rel ) −1 , are used to individually revise the measured DRCs for comparison with Monte Carlo calculated values and TG-43U1 or TG-43U1S1 consensus values. Results: In general, f rel is sensitive to the energy spectra and models of the brachytherapy seeds. Values may vary up to 8.4% among 125 I and 103 Pd seed models and common TLD shapes. P phant values depend primarily on the isotope used. Deduced (k bq rel ) −1 values are 1.074 ± 0.015 and 1.084 ± 0.026 for 125 I and 103 Pd seeds, respectively. For (1 mm) 3 chips, this implies an overall absorbed-dose sensitivity relative to 60 Co or 6 MV calibrations of 1.51 ± 1% and 1.47 ± 2% for 125 I and 103 Pd seeds, respectively, as opposed to the widely used value of 1.41. Values of P phant calculated here have much lower statistical uncertainties than literature values, but systematic uncertainties from density and composition uncertainties are significant. Using these revised values with the literature’s DRC measurements, the

  19. Cluster pattern analysis of energy deposition sites for the brachytherapy sources 103Pd, 125I, 192Ir, 137Cs, and 60Co.

    Science.gov (United States)

    Villegas, Fernanda; Tilly, Nina; Bäckström, Gloria; Ahnesjö, Anders

    2014-09-21

    Analysing the pattern of energy depositions may help elucidate differences in the severity of radiation-induced DNA strand breakage for different radiation qualities. It is often claimed that energy deposition (ED) sites from photon radiation form a uniform random pattern, but there is indication of differences in RBE values among different photon sources used in brachytherapy. The aim of this work is to analyse the spatial patterns of EDs from 103Pd, 125I, 192Ir, 137Cs sources commonly used in brachytherapy and a 60Co source as a reference radiation. The results suggest that there is both a non-uniform and a uniform random component to the frequency distribution of distances to the nearest neighbour ED. The closest neighbouring EDs show high spatial correlation for all investigated radiation qualities, whilst the uniform random component dominates for neighbours with longer distances for the three higher mean photon energy sources (192Ir, 137Cs, and 60Co). The two lower energy photon emitters (103Pd and 125I) present a very small uniform random component. The ratio of frequencies of clusters with respect to 60Co differs up to 15% for the lower energy sources and less than 2% for the higher energy sources when the maximum distance between each pair of EDs is 2 nm. At distances relevant to DNA damage, cluster patterns can be differentiated between the lower and higher energy sources. This may be part of the explanation to the reported difference in RBE values with initial DSB yields as an endpoint for these brachytherapy sources.

  20. Isodose curves recorded in radiochromic film of an iodine seed array

    International Nuclear Information System (INIS)

    Mourao, Arnaldo Prata; Tomaz, Lucas Crusoe; Grynberg, Suely Epzstein

    2015-01-01

    Brachytherapy seeds are frequently used in cancer treatment. Iodine seeds are ranked among the top choices when it comes to the treatment of prostate cancer. Iodine-125 emits X and gamma photons with an average energy of 28 keV and a half-life of 59.4 days. A set of four iodine-125 seeds, model 6711 produced by Amersham Health, were used in this work. The dosimetric characteristics for a seed were obtained taking into account the recommendations of TG-43 protocol, developed by the AAPM (American Association of Physicists in Medicine). To realize the experiment three plates of Standard Grade Solid Water, model 457 ® Gammex were used. One solid water plate was machined for accommodate the seed set. The set of seeds was placed in a symmetrical configuration trying to simulate an arrangement which may occur in vivo during treatment. A radiochromic film sheet was placed on the plate machined after the seed charge. The machined plate charged and with the film sheet was placed between two others solid water plate to recorder the radiation dose. The machined plate was placed between the other two plates for better reliability in measurements. The radio chromic film was irradiated by an equivalent X-ray beam using the reference radiation RQR 3 IEC (International Electrotechnical Commission) with different doses (0.5 to 1.0 Gy) to obtain the calibration curve in the dose region measured. After validation of the methodology, the study of the interaction between the radiation fields of the set of seeds became possible and the survey of isodose curves of these setting was conducted. (author)

  1. Influence of modifications in the positioning of phantoms in the Monte Carlo computational simulation of the prostate brachytherapy; Influencia de alteracoes no posicionamento de fantomas nas simulacoes computacionais Monte Carlo de braquiterapia de prostata

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Antonio Konrado de Santana; Vieira, Jose Wilson, E-mail: konrado.radiologia@gmail.co, E-mail: jose.wilson59@uol.com.b [Instituto Federal de Educacao, Ciencia e Tecnologia (IFPE), Recife, PE (Brazil); Costa, Kleber Souza Silva [Faculdade Integrada de Pernambuco (FACIPE), Recife, PE (Brazil); Lima, Fernando Roberto de Andrade, E-mail: falima@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2011-07-01

    Radiotherapy simulation procedures using Monte Carlo methods have shown to be increasingly important to the improvement of cancer fighting strategies. Within this context, brachytherapy is one of the most used methods to ensure better life quality when compared to other therapeutic modalities. These procedures are planned with the use of sectional exams with the patient in lying position. However, it is known that alteration of body posture after the procedure has an influence in the localization of many organs. This study had the aim to identify and to measure the influence of such alterations in MC brachytherapy simulations. In order to do so, prostate brachytherapy with the use of Iodine-125 radionuclide was chosen as model. Simulations were carried out with 108 events using EGSnrc code associated to MASH phantom in orthostatic and supine positions. Significant alterations were found, especially regarding bladder, small intestine and testicles. (author)

  2. Survey of brachytherapy practice in the United States: a report of the Clinical Research Committee of the American Endocurietherapy Society.

    Science.gov (United States)

    Nag, S; Owen, J B; Farnan, N; Pajak, T F; Martinez, A; Porter, A; Blasko, J; Harrison, L B

    1995-01-01

    To obtain reliable data on the extent of the brachytherapy practice in the United States by conducting a comprehensive survey of all facilities. The Clinical Research Committee of the AES surveyed all 1321 radiation oncology facilities identified in the Patterns of Care Study (PCS) of the American College of Radiology (ACR). Multiple mailings and follow-up were made to obtain a high response rate. Survey responders and nonresponders were compared using chi-square tests. Summary statistics were reported. Of the 1321 facilities, 1054 responded (80%). Hospital-based and larger facilities had a statistically significant higher rate of response. Brachytherapy was being performed at 819 facilities (the median number of procedures = 21-50). Two hundred and two facilities did no brachytherapy. The common isotopes used were 137Cs (705 facilities), 192Ir (585 facilities), 125I (236 facilities), and 131I (194 facilities). The common brachytherapy techniques used were intracavitary (751 facilities), interstitial (536 facilities), intraluminal (310 facilities), and plaques (148 facilities). Remote afterloaded brachytherapy was used at 205 centers as follows: high dose rate (HDR) (164), medium dose rate (MDR) (5), and low dose rate (LDR) (36). Computerized dosimetry was most commonly used (790 facilities), followed by Patterson-Parker (104 facilities) and Quimby (72 facilities). The common sites treated were cervix (701 facilities), endometrium (565 facilities), head and neck (354 facilities), and lung (344 facilities). Data regarding brachytherapy practice has been obtained from a large percentage (80%) of all facilities in the United States. The majority (78-81%) of radiation oncology facilities perform brachytherapy; however, its use is restricted to gynecological implants in many of these centers. The results from this survey will be used to develop a pattern of care study and data registry in brachytherapy.

  3. Chemisorption of iodine-125 to gold nanoparticles allows for real-time quantitation and potential use in nanomedicine

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Adrian A, E-mail: a.walsh@nanobiosols.com [Liverpool Science Park, Nano Biosols Ltd (United Kingdom)

    2017-04-15

    Gold nanoparticles have been available for many years as a research tool in the life sciences due to their electron density and optical properties. New applications are continually being developed, particularly in nanomedicine. One drawback is the need for an easy, real-time quantitation method for gold nanoparticles so that the effects observed in in vitro cell toxicity assays and cell uptake studies can be interpreted quantitatively in terms of nanoparticle loading. One potential method of quantifying gold nanoparticles in real time is by chemisorption of iodine-125, a gamma emitter, to the nanoparticles. This paper revisits the labelling of gold nanoparticles with iodine-125, first described 30 years ago and never fully exploited since. We explore the chemical properties and usefulness in quantifying bio-functionalised gold nanoparticle binding in a quick and simple manner. The gold particles were labelled specifically and quantitatively simply by mixing the two items. The nature of the labelling is chemisorption and is robust, remaining bound over several weeks in a variety of cell culture media. Chemisorption was confirmed as potassium iodide can remove the label whereas sodium chloride and many other buffers had no effect. Particles precoated in polymers or proteins can be labelled just as efficiently allowing for post-labelling experiments in situ rather than using radioactive gold atoms in the production process. We also demonstrate that interparticle exchange of I-125 between different size particles does not appear to take place confirming the affinity of the binding.

  4. Chemisorption of iodine-125 to gold nanoparticles allows for real-time quantitation and potential use in nanomedicine

    Science.gov (United States)

    Walsh, Adrian A.

    2017-04-01

    Gold nanoparticles have been available for many years as a research tool in the life sciences due to their electron density and optical properties. New applications are continually being developed, particularly in nanomedicine. One drawback is the need for an easy, real-time quantitation method for gold nanoparticles so that the effects observed in in vitro cell toxicity assays and cell uptake studies can be interpreted quantitatively in terms of nanoparticle loading. One potential method of quantifying gold nanoparticles in real time is by chemisorption of iodine-125, a gamma emitter, to the nanoparticles. This paper revisits the labelling of gold nanoparticles with iodine-125, first described 30 years ago and never fully exploited since. We explore the chemical properties and usefulness in quantifying bio-functionalised gold nanoparticle binding in a quick and simple manner. The gold particles were labelled specifically and quantitatively simply by mixing the two items. The nature of the labelling is chemisorption and is robust, remaining bound over several weeks in a variety of cell culture media. Chemisorption was confirmed as potassium iodide can remove the label whereas sodium chloride and many other buffers had no effect. Particles precoated in polymers or proteins can be labelled just as efficiently allowing for post-labelling experiments in situ rather than using radioactive gold atoms in the production process. We also demonstrate that interparticle exchange of I-125 between different size particles does not appear to take place confirming the affinity of the binding.

  5. Chemisorption of iodine-125 to gold nanoparticles allows for real-time quantitation and potential use in nanomedicine

    International Nuclear Information System (INIS)

    Walsh, Adrian A

    2017-01-01

    Gold nanoparticles have been available for many years as a research tool in the life sciences due to their electron density and optical properties. New applications are continually being developed, particularly in nanomedicine. One drawback is the need for an easy, real-time quantitation method for gold nanoparticles so that the effects observed in in vitro cell toxicity assays and cell uptake studies can be interpreted quantitatively in terms of nanoparticle loading. One potential method of quantifying gold nanoparticles in real time is by chemisorption of iodine-125, a gamma emitter, to the nanoparticles. This paper revisits the labelling of gold nanoparticles with iodine-125, first described 30 years ago and never fully exploited since. We explore the chemical properties and usefulness in quantifying bio-functionalised gold nanoparticle binding in a quick and simple manner. The gold particles were labelled specifically and quantitatively simply by mixing the two items. The nature of the labelling is chemisorption and is robust, remaining bound over several weeks in a variety of cell culture media. Chemisorption was confirmed as potassium iodide can remove the label whereas sodium chloride and many other buffers had no effect. Particles precoated in polymers or proteins can be labelled just as efficiently allowing for post-labelling experiments in situ rather than using radioactive gold atoms in the production process. We also demonstrate that interparticle exchange of I-125 between different size particles does not appear to take place confirming the affinity of the binding.

  6. Salvage stereotactic body radiotherapy for locally recurrent non-small cell lung cancer after sublobar resection and I125 vicryl mesh brachytherapy

    Directory of Open Access Journals (Sweden)

    Beant Singh Gill

    2015-05-01

    Full Text Available Purpose: Locally-recurrent non-small cell lung cancer (LR-NSCLC remains challenging treat, particularly in patients having received prior radiotherapy. Heterogeneous populations and varied treatment intent in existing literature result in significant limitations in evaluating efficacy of lung re-irradiation. In order to better establish the impact of re-irradiation in patients with LR-NSCLC following high-dose radiotherapy, we report outcomes for patients treated with prior sublobar resection and brachytherapy that subsequently underwent stereotactic body radiotherapy (SBRT.Methods: A retrospective review of patients initially treated with sublobar resection and I125 vicryl mesh brachytherapy, who later developed LR-NSCLC along the suture line, was performed. Patients received salvage SBRT with curative intent. Dose and fractionation was based on tumor location and size, with a median prescription dose of 48 Gy in 4 fractions (range 20-60 Gy in 1-4 fractions.Results: Thirteen consecutive patients were identified with median follow-up of 2.1 years (range 0.7-5.6 years. Two in-field local failures occurred at 7.5 and 11.1 months, resulting in 2-year local control of 83.9% (95% CI 63.5-100.0%. Two-year disease-free survival and overall survival estimates were 38.5% (95% CI 0.0-65.0% and 65.8% (95% CI, 38.2-93.4%. Four patients (31% remained disease-free at last follow-up. All but one patient who experienced disease recurrence developed isolated or synchronous distant metastases. Only one patient (7.7% developed grade ≥3 toxicity, consisting of grade 3 esophageal stricture following a centrally located recurrence previously treated with radiofrequency ablation.Conclusion: Despite high local radiation doses delivered to lung parenchyma previously with I125 brachytherapy, re-irradiation with SBRT for LR-NSCLC results in excellent local control with limited morbidity, allowing for potential disease cure in a subset of patients.

  7. Posttreatment visual acuity in patients treated with episcleral plaque therapy for choroidal melanomas: dose and dose rate effects

    International Nuclear Information System (INIS)

    Jones, Robert; Gore, Elizabeth; Mieler, William; Murray, Kevin; Gillin, Michael; Albano, Katherine; Erickson, Beth

    2002-01-01

    Purpose: To determine the relationship between the long-term visual function and the dose and dose rates delivered to critical ocular structures in patients with choroidal melanoma treated with 125 I episcleral plaque radiotherapy. Methods and Materials: From 1987 to 1994, 63 patients underwent 125 I episcleral plaque (Collaborative Ocular Melanoma Study [COMS] design) application for the treatment of choroidal melanoma. The mean tumor height was 4.5 mm (range 1.7-8.3). Doses and dose rates at the tumor apex, macula, and optic disc were calculated. Forty-three records were scored to assess whether a decrease in visual acuity of >2 lines on a standard Snellen eye chart had occurred. Patient age and the presence of hypertension or diabetes were noted. Statistical analysis was performed to assess both the rate at which visual decline had occurred and the presence of significant factors that had contributed to this decline. Results: With a median follow-up of 36 months, the 3-year actuarial survival rate was 93.6%. The 3-year actuarial local control rate was 86.9%. The median time to visual loss after therapy was 18.7 months. The 3-year actuarial rate of visual preservation was 40.5%. Multivariate analysis demonstrated higher macula dose rates (p=0.003) to forecast visual decline. Macula dose rates of 111±11.1 cGy/h were associated with a 50% risk of significant visual loss. Conclusion: Patients in our series treated with 125 I plaque brachytherapy for choroidal melanoma experienced favorable tumor control, but with a measurable incidence of visual decline. Higher dose rates to the macula correlated strongly with poorer posttreatment visual outcome. This information may be valuable in selecting the optimal dose rates to treat choroidal melanomas and to predict the risk of visual decline

  8. Brachytherapy in early prostate cancer--early experience.

    Science.gov (United States)

    Jose, B O; Bailen, J L; Albrink, F H; Steinbock, G S; Cornett, M S; Benson, D C; Schmied, W K; Medley, R N; Spanos, W J; Paris, K J; Koerner, P D; Gatenby, R A; Wilson, D L; Meyer, R

    1999-01-01

    Use of brachytherapy with radioactive seeds in the management of early prostate cancer is commonly used in the United States. The early experience has been reported from the prostate treatment centers in Seattle for the last 10 years. In this manuscript we are reporting our early experience of 150 radioactive seed implantations in early stage prostate cancer using either Iodine 125 or Palladium 103 seeds. The average age of the patient is 66 years and the median Gleason score is 5.4 with a median PSA of 6. A brief description of the evolution of the treatment of prostate cancer as well as the preparation for the seed implantation using the volume study with ultrasound of the prostate, pubic arch study using CT scan of the pelvis and the complete planning using the treatment planning computers are discussed. We also have described the current technique which is used in our experience based on the Seattle guidelines. We plan a follow-up report with the results of the studies with longer follow-up.

  9. NMDA receptor channels: labeling of MK-801 with iodine-125 and fluorine-18

    International Nuclear Information System (INIS)

    Wieland, D.M.; Kilbourn, M.R.; Yang, D.J.; Laborde, E.; Gildersleeve, D.L.; Van Dort, M.E.; Pirat, J.-L.; Ciliax, B.J.; Young, A.B.

    1988-01-01

    Methods for labeling the glutamate channel blocking agent MK-801 with iodine-125 ( 125 I) and fluorine-18 ( 18 F) are described. Radioiodine was incorporated in the 1- or 3-positions of the aromatic ring of (±)MK-801 by solid-state halogen exchange techniques. Attachment of the [ 18 F]fluoromethyl group to the bridgehead methyl position was achieved by reaction of [ 18 F]fluoride with the triflamide alcohol or the novel cyclic sulfamate recently reported by Merck chemists. Radiochemical yields of (±)13-[ 18 F]-fluoromethyl-MK-801 were >72%, EOB; radiochemical purity > 99%. In competitive binding studies using rat brain homogenates, (±)3-bromo-MK-801 showed greater affinity than (±)MK-801 for the glutamate-linked channel. The experimental log P (2.1 ± 0.1) of MK-801 is optimal for transit of the blood-brain barrier. These preliminary findings support further testing of [ 123 I]iodo-MK-801 and [ 18 F]fluoromethyl-MK-801 as possible agents for in vivo mapping of the glutamate receptor complex. (author)

  10. Investigation on curative efficacy for malignant tumor by implantation '125I permanent brachytherapy seeds

    International Nuclear Information System (INIS)

    Hu Shu; Gao Zhou; Jia Shaowei; Cheng Xianyi; Chen Junhui; Yin Weihua; Sun Desheng

    2011-01-01

    Twenty inpatients suffered from malignant tumors with twenty-four lesions were treated with 125 I permanent brachytherapy seed in Peking University Shenzhen Hospital, and the feasibility, curative effect and adverse effect of the treatment were observed. Before 125 I seeds implantation, the three-dimensional treatment planning was preconcerted. There were two methods to implant 125 I seeds. One was to insert the seeds in the location of residual focus and metastatic lesions of the tumors directly in ordinary operations or through laparoscopy under general anesthesia. The other w as to implant the seeds into the tumors through percutaneous needles by the guidance of CT scanning or color doppler ultrasonography under local anesthesia. The implantations for all of the 20 patients (24 lesions) were performed successfully. During and one week after the implantation, the distributions of the planted seeds were approximately the same as the scheduled three-dimensional treatment planning, and no seed migration was found. Adverse reactions during and after the operation were slight and recovered after correlative treatments. Clinical symptoms were palliated and ser um tumor marker decreased to a different extent among most patients. The complete remission (CR) rate is 20.00% (4/20 patients ), the partial emission (PR) rate is 35.00% (7/20 patients), the stable disease (SD) rate is 30.00% (6/20 patients), the progressive disease (PD) rate is 15.00% (3/20 patients), and the overall response rate (CR + PR) is 53.33% (8 patients). 125 I seeds implantation for targeted therapy is convenient, safe and effective on malignant tumor, and is well worth advanced application. (authors)

  11. Histology study on the dorsal root ganglia of rats with 125I seed brachytherapy at intervertebral foramen

    International Nuclear Information System (INIS)

    Zhang Wenyi; Wang Huixing; Ding Yanqiu; Qu Ximei; Wang Liqin; Liu Zhongchao; Cui Songye; Jiao Ling

    2012-01-01

    Objective: To investigate the effect of the histological changes on rat dorsal root ganglia (DRG) after 125 I seed brachytherapy.Methods Twelve adult male Sprague-Dawley rats (150-180 g each) were randomly divided into 6 groups, 125 I seeds with different activities of 0 (Titanium shell), 14.8, 18.5, 22.2, 25.9 and 29.6 MBq were implanted to 6 groups of rats respectively and the behavioral changes of rats were observed. The rats were killed in different periods after implantation,the morphological changes in DRG and surrounding muscle tissue were observed with an Olympus BX51 optical microscope and then the irradiation doses were estimated. Results: After 125 I seed implantation, the movement function of rats was not affected and the weight of rats gained after 7 days. After the titanium shell implantation, very few mild swelling was induced in neuroganglion cells that still had clear nucleolus and normal cytoplasm. At 14 days after 18.5 MBq seed implantation, cell swelling was more serious and cell dehydrating, nuclear condensation and nuclear fragmentation appeared after 30 days. At 60 days after 29.6 MBq of seed implantation, nuclear dissolution and cytoplasmic shrinkage were induced in a large number of cells.In general, the severity of fibrosis was aggravated with the time post-irradiation and the dose in the muscles around the ganglion. Conclusions: After 125 I seed implantation,the injury degree of DRG tissue is dose-dependent, and the 125 I seed irradiation would have analgesic effect on releasing intractable pain. (authors)

  12. Ultrasonically guided 125iodine seed implantation with external radiation in management of localized prostatic carcinoma

    DEFF Research Database (Denmark)

    Iversen, P; Bak, M; Juul, N

    1989-01-01

    Thirty-three patients with localized prostatic carcinoma (16 poorly differentiated) were treated with transperineal 125Iodine seed implantation (160 Gy) guided by transrectal ultrasonography and subsequent external beam irradiation (47.4 Gy). The observation time was six to sixty-eight months...... with a median follow-up of thirty-five months. Median change in prostatic volume was a reduction of 35 percent. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after one to two years, revealing still malignant histology in 12 (48%). Development of distant metastases occurred...

  13. Influence of radioactive sources discretization in the Monte Carlo computational simulations of brachytherapy procedures: a case study on the procedures for treatment of prostate cancer; Influencia da discretizacao das fontes radioativas nas simulacoes computacionais Monte Carlo de procedimentos de braquiterapia: um estudo de caso sobre os procedimentos para tratamento do cancer de prostata

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Antonio Konrado de Santana; Vieira, Jose Wilson [Instituto Federal de Educacao, Ciencia e Tecnologia (IFPE), Recife, PE (Brazil); Costa, Kleber Souza Silva [Faculdade Integrada de Pernambuco (FACIPE), Recife, PE (Brazil); Lima, Fernando Roberto de Andrade, E-mail: falima@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2011-07-01

    Radiotherapy computational simulation procedures using Monte Carlo (MC) methods have shown to be increasingly important to the improvement of cancer fighting strategies. One of the biases in this practice is the discretization of the radioactive source in brachytherapy simulations, which often do not match with a real situation. This study had the aim to identify and to measure the influence of radioactive sources discretization in brachytherapy MC simulations when compared to those that do not present discretization, using prostate brachytherapy with Iodine-125 radionuclide as model. Simulations were carried out with 108 events with both types of sources to compare them using EGSnrc code associated to MASH phantom in orthostatic and supine positions with some anatomic adaptations. Significant alterations were found, especially regarding bladder, rectum and the prostate itself. It can be concluded that there is a need to discretized sources in brachytherapy simulations to ensure its representativeness. (author)

  14. The Effect of Scattering from Leg Region on Organ Doses in Prostate Brachytherapy for 103Pd, 125I and 131Cs Seeds

    Directory of Open Access Journals (Sweden)

    Seyed Milad Vahabi

    2016-09-01

    Full Text Available Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125I, 103Pd, and 131Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the legs on dose calculations. Materials and Methods The doses to organs of interest were calculated using MCNPX code and ORNL (Oak Ridge National Laboratory phantom. Results Doses to the prostate as a source of radiation for 125I, 103Pd, and 131Cs were approximately 108.9, 97.7, and 81.5 Gy, respectively. Bladder, sigmoid colon, and testes received higher doses than other organs due to proximity to the prostate. Differences between the doses when tallying with the legs intact and with the legs voided were significant for testes, sigmoid colon contents, and sigmoid colon wall because of their proximity to the prostate. There was also a good consistency between our results and the data published by Montefiore Medical Center and Albert Einstein College of Medicine for the prostate. Conclusion Scattering from leg region had a significant effect on doses to testes, sigmoid colon contents, and sigmoid colon wall in the pelvic region, and prostate and the other organs were unaffected. Brachytherapy treatment plans using 131Cs seeds allow for better sparing of critical tissues, with a comparable number of, or fewer, seeds required, compared to 125I seeds.

  15. Post-treatment visual acuity in patients treated with episcleral plaque therapy for choroidal melanoma: Dose and dose rate effects

    International Nuclear Information System (INIS)

    Jones, Robert; Gore, Elizabeth; Mieler, William; Gillin, Michael; Albano, Katherine; Erickson, Beth

    1996-01-01

    Purpose: To determine the relationship between the long-term visual function and the dose and dose rates delivered to critical ocular structures in patients with choroidal melanoma treated with 125 I episcleral plaque radiotherapy. Methods and Materials: From 1987 to 1993, 63 patients underwent 125 I episcleral plaque application for the treatment of choroidal melanoma. Mean tumor height was 4.6 mm (range 1.7-8.3 mm). Plaques utilized were of COMS design. Doses and dose rates at the tumor apex, macula, and optic disc were obtained. Visual acuity data prior to and after plaque application was available for 52 patients. 9 patients were excluded from analysis secondary to co-morbidities or disease progression. 43 records were scored to assess if a decrease in visual acuity of ≥ 2 lines on a standard Snellen eye chart had occurred. Statistical analysis was performed using chi-square tests of significance. Results: Of the 63 total patients, 59 (93.7%) were alive at a median follow-up of 36 months. Local progression occurred in (7(63)) (11.1%). Median dose and dose rate to the tumor apex were 90 Gy and 97.2 cGy/hr, respectively. Of the 43 patients with post-treatment visual acuity analysis, 28 (65.1%) experienced visual loss of ≥ 2 lines on a standard eye chart. Median time to altered visual acuity was 20 months. Median dose and dose rates to the macula in patients with a significant visual loss were 123.3 Gy and 122.5 cGy/hr, respectively, compared with 38 Gy and 51.9 cGy/hr in those without notable visual change. These differences reached statistical significance at a dose and dose rate to the macula of 82.0 Gy (p 125 I plaque brachytherapy for choroidal melanoma experienced favorable tumor control, but with a measurable incidence of decreased visual acuity. Both total dose and dose rates to the macula and optic disc correlated strongly with post-treatment visual outcome. This information may be valuable in decisions about the dose and dose rates used to treat

  16. Post-treatment visual acuity in patients treated with episcleral plaque therapy for choroidal melanoma: dose and dose rate effects

    International Nuclear Information System (INIS)

    Jones, Robert; Gore, Elizabeth; Mieler, William; Murray, Kevin; Gillin, Michael; Albano, Katherine; Erickson, Beth

    1996-01-01

    Purpose: To determine the relationship between the long-term visual function and the dose and dose rates delivered to critical ocular structures in patients with choroidal melanoma treated with 125 I episcleral plaque radiotherapy. Methods and Materials: From 1987 to 1994, 63 patients underwent 125 I episcleral plaque application for the treatment of choroidal melanoma. Mean tumor height was 4.6 mm (range 1.7-8.3 mm). Plaques utilized were of COMS design. Doses and dose rates at the tumor apex, macula, and optic disc were obtained. Visual acuity data prior to and after plaque application was available for 52 patients. Nine patients were excluded from analysis secondary to co-morbidities or disease progression. Forty-three records were scored to assess if a decrease in visual acuity of ≥ 2 lines on a standard Snellen eye chart had occurred. Statistical analysis was performed using chi-square tests of significance. Results: Of the 63 total patients, 59 (93.7%) were alive at a median follow-up of 36 months. Local progression occurred in 7/63 (11.1%). Median dose and dose rate to the tumor apex were 90 Gy and 97.2 cGy/hr, respectively. Of the 43 patients with post-treatment visual acuity analysis, 28 (65.1%) experienced visual loss of ≥ 2 lines on a standard eye chart. Median time to altered visual acuity was 20 months. Median dose and dose rates to the macula in patients with a significant visual loss were 123.3 Gy and 122.5 cGy/hr, respectively, compared with 38 Gy and 51.9 cGy/hr in those without notable visual change. These differences reached statistical significance at a dose and dose rate to the macula of 82.0 Gy (p 125 I plaque brachytherapy for choroidal melanoma experienced favorable tumor control, but with a measurable incidence of decreased visual acuity. Both total dose and dose rates to the macula and optic disc correlated strongly with post-treatment visual outcome. This information may be valuable in decisions about the dose and dose rates used to

  17. Iodine-125 in the fresh water environment in England; measurements along the pathway from sewage discharge to thyroid glands and determinations of absorbed dose to humans

    International Nuclear Information System (INIS)

    Howe, J.R.; Bowlt, C.

    1992-01-01

    Iodine-125 has been measured in the fresh water supply in England, particularly in the Thames Valley. 125 I discarded into the sewage drainage system, travels in the liquid effluent into rivers. When mains water is abstracted downstream from such discharges low levels of 125 I ( 125 I. However it was never possible to establish more than a semi-quantitative relationship between their activity levels and those of their surroundings. In general, levels of 125 I have shown a 3-4 fold increase in the fresh water environment during the 1980's. (Author)

  18. Altering iodine metabolism in the calf by feeding iodine-binding agents

    International Nuclear Information System (INIS)

    Miller, J.K.; Swanson, E.W.; Lyke, W.A.; Byrne, W.F.

    1975-01-01

    Effects of feeding cottonseed meal and anion-exchange resin on iodine absorption and excretion by calves were investigated. Each additional amount of resin fed from 0.3 to 3.5 g/kg body weight further increased fecal excretion from single oral iodine-131 and intravenous iodine-125 doses. By feeding 3 to 10 g cottonseed meal/kg body weight, excretion of oral iodine-131 given daily was increased 7 to 94 percent in feces and reduced as much as 35 percent in urine, but plasma iodine-131 was not changed. Introducing 1 g resin/kg body weight daily into the diet increased fecal iodine-131 excretion three to five times that with cottonseed meal alone and reduced both plasma and urinary iodine-131. The same amount of resin fed daily had similar effects on excretion of iodine-131 injected subcutaneously each day. Although iodine depletion by a highly efficient iodine binder (resin) in the gastrointestinal tract is probable, iodine binding by a natural feed constituent (cottonseed meal) was relatively inefficient. (U.S.)

  19. Altering iodine metabolism in the calf by feeding iodine-binding agents

    International Nuclear Information System (INIS)

    Miller, J.K.; Swanson, E.W.; Lyke, W.A.; Byrne, W.F.

    1975-01-01

    Effects of feeding cottonseed meal and anion-exchange resin on iodine absorption and excretion by calves were investigated. Each additional amount of resin fed from 0.3 to 3.5 g/kg body weight further increased fecal excretion from single oral iodine-131 and intravenous iodine-125 doses. By feeding 3 to 10 g cottonseed meal/kg body weight, excretion of oral iodine-131 given daily was increased 7 to 94 percent in feces and reduced as much as 35 percent in urine, but plasma iodine-131 was not changed. Introducing 1 g resin/kg body weight daily into the diet increased fecal iodine-131 excretion three to five times that with cottonseed meal alone and reduced both plasma and urinary iodine-131. The same amount of resin fed daily had similar effects on excretion of iodine-131 injected subcutaneously each day. Although iodine depletion by a highly efficient iodine binder (resin) in the gastrointestinal tract is probable, iodine binding by a natural feed constituent (cottonseed meal) was relatively inefficient. (auth)

  20. Low dose rate Ir-192 interstitial brachytherapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Oki, Yosuke; Dokiya, Takushi; Yorozu, Atsunori; Suzuki, Takayuki; Saito, Shiro; Monma, Tetsuo; Ohki, Takahiro [National Tokyo Medical Center (Japan); Murai, Masaru; Kubo, Atsushi

    2000-04-01

    From December 1997 through January 1999, fifteen prostatic cancer patients were treated with low dose rate Ir-192 interstitial brachytherapy using TRUS and perineal template guidance without external radiotherapy. Up to now, as no apparent side effects were found, the safety of this treatment is suggested. In the future, in order to treat prostatic cancer patients with interstitial brachytherapy using I-125 or Pd-103, more investigation for this low dose rate Ir-192 interstitial brachytherapy is needed. (author)

  1. Amplification of oncogenes and integrated SV40 sequences in mammalian cells by the decay of incorporated iodine-125

    International Nuclear Information System (INIS)

    Ehrfeld, A.; Planas-Bohne, F.; Luecke-Huhle, C.

    1986-01-01

    Iodine-125, in the form of 5-[ 125 I]iododeoxyuridine (I-UdR), was incorporated into the DNA of SV40 transformed Chinese hamster embryo cells. Disintegration of the 125 I led to increased cell killing with increasing dose as measured by the colony-forming ability of single cells. The D37 (the dose at which 37% of the cells survive) amounts to 95 decays per cell, corresponding to 0.66 Gy. Variations in the copy number of specific DNA sequences was measured by using dispersed cell blotting with sensitive DNA hybridizations. A 13-fold amplification of the viral DNA sequences (SV40) and a twofold amplification of two cellular oncogenes of the ras-family (Ki-ras and Ha-ras) were found. Other cellular genes, like the alpha-actin gene, were not amplified, and no variation in gene copy number was detected after incubation of cells with cold I-UdR. We suggest the observed gene amplifications are induced by the densely ionizing radiation emitted by the decay of the incorporated 125 I atoms

  2. Incidence of seed migration to the chest, abdomen, and pelvis after transperineal interstitial prostate brachytherapy with loose 125I seeds

    International Nuclear Information System (INIS)

    Sugawara, Akitomo; Shigematsu, Naoyuki; Nakashima, Jun; Kunieda, Etsuo; Nagata, Hirohiko; Mizuno, Ryuichi; Seki, Satoshi; Shiraishi, Yutaka; Kouta, Ryuichi; Oya, Mototsugu

    2011-01-01

    The aim was to determine the incidence of seed migration not only to the chest, but also to the abdomen and pelvis after transperineal interstitial prostate brachytherapy with loose 125 I seeds. We reviewed the records of 267 patients who underwent prostate brachytherapy with loose 125 I seeds. After seed implantation, orthogonal chest radiographs, an abdominal radiograph, and a pelvic radiograph were undertaken routinely to document the occurrence and sites of seed migration. The incidence of seed migration to the chest, abdomen, and pelvis was calculated. All patients who had seed migration to the abdomen and pelvis subsequently underwent a computed tomography scan to identify the exact location of the migrated seeds. Postimplant dosimetric analysis was undertaken, and dosimetric results were compared between patients with and without seed migration. A total of 19,236 seeds were implanted in 267 patients. Overall, 91 of 19,236 (0.47%) seeds migrated in 66 of 267 (24.7%) patients. Sixty-nine (0.36%) seeds migrated to the chest in 54 (20.2%) patients. Seven (0.036%) seeds migrated to the abdomen in six (2.2%) patients. Fifteen (0.078%) seeds migrated to the pelvis in 15 (5.6%) patients. Seed migration occurred predominantly within two weeks after seed implantation. None of the 66 patients had symptoms related to the migrated seeds. Postimplant prostate D90 was not significantly different between patients with and without seed migration. We showed the incidence of seed migration to the chest, abdomen and pelvis. Seed migration did not have a significant effect on postimplant prostate D90

  3. Radiological protection on interstitial brachytherapy and dose determination and exposure rate of an Ir-192 source through the MCNP-4B

    International Nuclear Information System (INIS)

    Morales L, M.E.

    2006-01-01

    The present work was carried out in the Neurological Sciences Institute having as objective to determine the dose and the rate of exhibition of the sources of Iridium 192, Iodine 125 and Palladium 103; which are used to carry out implant in the Interstitial Brachytherapy according to the TG43. For it we carry out a theoretical calculation, its are defined in the enter file: the geometry, materials of the problem and the radiation source, etc; in the MCNP-4B Monte Carlo code, considering a punctual source and for the dose determination we simulate thermoluminescent dosemeters (TLD): at 5 cm, 50 cm, 100 cm and 200 cm of the source. Our purpose is to analyze the radioprotection measures that should take into account in this Institute in which are carried out brain biopsies using a Micro mar stereotactic mark, and in a near future with the collaboration of a doctor and a cuban physique seeks to be carried out the Interstitial Brachytherapy technique with sources of Ir-192 for patient with tumors like glioblastoma, astrocytoma, etc. (Author)

  4. Directional interstitial brachytherapy from simulation to application

    Science.gov (United States)

    Lin, Liyong

    Organs at risk (OAR) are sometimes adjacent to or embedded in or overlap with the clinical target volume (CTV) to be treated. The purpose of this PhD study is to develop directionally low energy gamma-emitting interstitial brachytherapy sources. These sources can be applied between OAR to selectively reduce hot spots in the OARs and normal tissues. The reduction of dose over undesired regions can expand patient eligibility or reduce toxicities for the treatment by conventional interstitial brachytherapy. This study covers the development of a directional source from design optimization to construction of the first prototype source. The Monte Carlo code MCNP was used to simulate the radiation transport for the designs of directional sources. We have made a special construction kit to assemble radioactive and gold-shield components precisely into D-shaped titanium containers of the first directional source. Directional sources have a similar dose distribution as conventional sources on the treated side but greatly reduced dose on the shielded side, with a sharp dose gradient between them. A three-dimensional dose deposition kernel for the 125I directional source has been calculated. Treatment plans can use both directional and conventional 125I sources at the same source strength for low-dose-rate (LDR) implants to optimize the dose distributions. For prostate tumors, directional 125I LDR brachytherapy can potentially reduce genitourinary and gastrointestinal toxicities and improve potency preservation for low risk patients. The combination of better dose distribution of directional implants and better therapeutic ratio between tumor response and late reactions enables a novel temporary LDR treatment, as opposed to permanent or high-dose-rate (HDR) brachytherapy for the intermediate risk T2b and high risk T2c tumors. Supplemental external-beam treatments can be shortened with a better brachytherapy boost for T3 tumors. In conclusion, we have successfully finished the

  5. Development of prostate voxel models for brachytherapy treatment

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Adriano M.; Reis, Lucas P.; Grynberg, Suely E., E-mail: amsantos@cdtn.b [Center for Development of Nuclear Technology (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    The tools developed recently in the areas of computer graphics and animation movies to computer games allow the creation of new voxel anthropomorphic phantoms with better resolution and thus, more anatomical details. These phantoms can be used in nuclear applications, especially in radiation protection for estimating doses in cases of occupational or accidental radioactive incidents, and in medical and biological applications. For dose estimates, the phantoms are coupled to a Monte Carlo code, which will be responsible for the transport of radiation in this environment. This study aimed to develop a computational tool to estimate the isodose curves in the prostate after brachytherapy seed implants. For this, we have created a model called FANTPROST in the shape of a 48 mm side cube, with a standard prostate inserted in the center of this cube with different distributions of brachytherapy seeds in this volume. The prostate, according to this model, was obtained from the phantom voxels MASH2 developed by Numerical Dosimetry Group, Department of Nuclear Energy - Federal University of Pernambuco. The modeling of the seeds, added to FANTPROST, was done through the use of geometric information of Iodine-125 Amersham 6711 commercial seed. The simulations were performed by the code MCNP5 for spatial distributions containing different amounts of seeds within the FANTPROST. The obtained curves allowed an estimation of the behavior of the maximum dose that decreases with distance, showing that this tool can be used for a more accurate analysis of the effects produced by the presence of such seeds in the prostate and its vicinity. (author)

  6. Establishing High-Quality Prostate Brachytherapy Using a Phantom Simulator Training Program

    Energy Technology Data Exchange (ETDEWEB)

    Thaker, Nikhil G. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Kudchadker, Rajat J. [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Swanson, David A. [Department of Urology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Albert, Jeffrey M. [Department of Radiation Oncology, Banner Health, Loveland/Greeley, Colorado (United States); Mahmood, Usama; Pugh, Thomas J.; Boehling, Nicholas S. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Bruno, Teresa L. [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Prestidge, Bradley R. [Department of Radiation Oncology, Bon Secours Health System, Norfolk, Virginia (United States); Crook, Juanita M. [Department of Radiation Oncology, Cancer Center for the Southern Interior, Kelowna, British Columbia (Canada); Cox, Brett W.; Potters, Louis [Department of Radiation Medicine, North Shore-LIJ Health System, New Hyde Park, New York (United States); Moran, Brian J. [Chicago Prostate Center, Westmont, Illinois (United States); Keyes, Mira [Department of Radiation Oncology, British Columbia Cancer Agency, Vancouver Center, Vancouver, British Columbia (Canada); Kuban, Deborah A. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Frank, Steven J., E-mail: sjfrank@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2014-11-01

    Purpose: To design and implement a unique training program that uses a phantom-based simulator to teach the process of prostate brachytherapy (PB) quality assurance and improve the quality of education. Methods and Materials: Trainees in our simulator program were practicing radiation oncologists, radiation oncology residents, and fellows of the American Brachytherapy Society. The program emphasized 6 core areas of quality assurance: patient selection, simulation, treatment planning, implant technique, treatment evaluation, and outcome assessment. Using the Iodine 125 ({sup 125}I) preoperative treatment planning technique, trainees implanted their ultrasound phantoms with dummy seeds (ie, seeds with no activity). Pre- and postimplant dosimetric parameters were compared and correlated using regression analysis. Results: Thirty-one trainees successfully completed the simulator program during the period under study. The mean phantom prostate size, number of seeds used, and total activity were generally consistent between trainees. All trainees met the V100 >95% objective both before and after implantation. Regardless of the initial volume of the prostate phantom, trainees' ability to cover the target volume with at least 100% of the dose (V100) was not compromised (R=0.99 pre- and postimplant). However, the V150 had lower concordance (R=0.37) and may better reflect heterogeneity control of the implant process. Conclusions: Analysis of implants from this phantom-based simulator shows a high degree of consistency between trainees and uniformly high-quality implants with respect to parameters used in clinical practice. This training program provides a valuable educational opportunity that improves the quality of PB training and likely accelerates the learning curve inherent in PB. Prostate phantom implantation can be a valuable first step in the acquisition of the required skills to safely perform PB.

  7. Establishing High-Quality Prostate Brachytherapy Using a Phantom Simulator Training Program

    International Nuclear Information System (INIS)

    Thaker, Nikhil G.; Kudchadker, Rajat J.; Swanson, David A.; Albert, Jeffrey M.; Mahmood, Usama; Pugh, Thomas J.; Boehling, Nicholas S.; Bruno, Teresa L.; Prestidge, Bradley R.; Crook, Juanita M.; Cox, Brett W.; Potters, Louis; Moran, Brian J.; Keyes, Mira; Kuban, Deborah A.; Frank, Steven J.

    2014-01-01

    Purpose: To design and implement a unique training program that uses a phantom-based simulator to teach the process of prostate brachytherapy (PB) quality assurance and improve the quality of education. Methods and Materials: Trainees in our simulator program were practicing radiation oncologists, radiation oncology residents, and fellows of the American Brachytherapy Society. The program emphasized 6 core areas of quality assurance: patient selection, simulation, treatment planning, implant technique, treatment evaluation, and outcome assessment. Using the Iodine 125 ( 125 I) preoperative treatment planning technique, trainees implanted their ultrasound phantoms with dummy seeds (ie, seeds with no activity). Pre- and postimplant dosimetric parameters were compared and correlated using regression analysis. Results: Thirty-one trainees successfully completed the simulator program during the period under study. The mean phantom prostate size, number of seeds used, and total activity were generally consistent between trainees. All trainees met the V100 >95% objective both before and after implantation. Regardless of the initial volume of the prostate phantom, trainees' ability to cover the target volume with at least 100% of the dose (V100) was not compromised (R=0.99 pre- and postimplant). However, the V150 had lower concordance (R=0.37) and may better reflect heterogeneity control of the implant process. Conclusions: Analysis of implants from this phantom-based simulator shows a high degree of consistency between trainees and uniformly high-quality implants with respect to parameters used in clinical practice. This training program provides a valuable educational opportunity that improves the quality of PB training and likely accelerates the learning curve inherent in PB. Prostate phantom implantation can be a valuable first step in the acquisition of the required skills to safely perform PB

  8. Factors influencing upon the incidence of seed migration in I-125 seed transperineal prostate implantation

    International Nuclear Information System (INIS)

    Itami, Jun; Onishi, Kayoko; Kanemura, Mikio

    2005-01-01

    Transperineal I-125 seed brachytherapy for prostate cancer is rapidly expanding in Japan. Seed migrations to lung and abdomen are well known complication in the seed brachytherapy. The rate of incidence and the predisposing factors were studied. From April 2004 through January 2005, 36 patients underwent transperineal I-125 seed brachytherapy for prostate cancer. In all patients loose I-125 seeds were inserted with Mick applicator according to modified peripheral loading pattern. One day, 1 week, and 1 month after the procedure, posteroanterior and lateral chest X-rays and abdominal X-ray were performed. Abdominal and chest seed migrations were seen in 11 (30.6%) and 14 (38.9%) patients, respectively. In total, 20 patients (55.6%) showed seed migrations. Forty-two I-125 seeds migrated out of 2,508 implanted seeds. Most of the migrations were seen until 1 month after the procedure. The preplanned number of the extraprostatic seeds had a statistically significant influence upon the incidence of seed migration. Seed migration is not a rare phenomenon in transperineal I-125 seed brachytherapy for prostate cancer. To confirm seed migration, X-ray examinations 1 month after the procedure are suited. At the preplanning, the number of extraprostatic seeds should be limited to minimal to decrease the incidence of seed migration. In future, the introduction of linked I-125 seeds is preferred. (author)

  9. Delivered dose uncertainty analysis at the tumor apex for ocular brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Hali, E-mail: hamorris@ualberta.ca; Menon, Geetha; Larocque, Matthew P.; Jans, Hans-Sonke; Sloboda, Ron S. [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada); Weis, Ezekiel [Department of Ophthalmology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada)

    2016-08-15

    Purpose: To estimate the total dosimetric uncertainty at the tumor apex for ocular brachytherapy treatments delivered using 16 mm Collaborative Ocular Melanoma Study (COMS) and Super9 plaques loaded with {sup 125}I seeds in order to determine the size of the apex margin that would be required to ensure adequate dosimetric coverage of the tumor. Methods: The total dosimetric uncertainty was assessed for three reference tumor heights: 3, 5, and 10 mm, using the Guide to the expression of Uncertainty in Measurement/National Institute of Standards and Technology approach. Uncertainties pertaining to seed construction, source strength, plaque assembly, treatment planning calculations, tumor height measurement, plaque placement, and plaque tilt for a simple dome-shaped tumor were investigated and quantified to estimate the total dosimetric uncertainty at the tumor apex. Uncertainties in seed construction were determined using EBT3 Gafchromic film measurements around single seeds, plaque assembly uncertainties were determined using high resolution microCT scanning of loaded plaques to measure seed positions in the plaques, and all other uncertainties were determined from the previously published studies and recommended values. All dose calculations were performed using PLAQUESIMULATOR v5.7.6 ophthalmic treatment planning system with the inclusion of plaque heterogeneity corrections. Results: The total dosimetric uncertainties at 3, 5, and 10 mm tumor heights for the 16 mm COMS plaque were 17.3%, 16.1%, and 14.2%, respectively, and for the Super9 plaque were 18.2%, 14.4%, and 13.1%, respectively (all values with coverage factor k = 2). The apex margins at 3, 5, and 10 mm tumor heights required to adequately account for these uncertainties were 1.3, 1.3, and 1.4 mm, respectively, for the 16 mm COMS plaque, and 1.8, 1.4, and 1.2 mm, respectively, for the Super9 plaque. These uncertainties and associated margins are dependent on the dose gradient at the given prescription

  10. Study of two different radioactive sources for prostate brachytherapy treatment

    International Nuclear Information System (INIS)

    Pereira Neves, Lucio; Perini, Ana Paula; Souza Santos, William de; Caldas, Linda V.E.; Belinato, Walmir

    2015-01-01

    In this study we evaluated two radioactive sources for brachytherapy treatments. Our main goal was to quantify the absorbed doses on organs and tissues of an adult male patient, submitted to a brachytherapy treatment with two radioactive sources. We evaluated a 192 Ir and a 125 I radioactive sources. The 192 Ir radioactive source is a cylinder with 0.09 cm in diameter and 0.415 cm long. The 125 I radioactive source is also a cylinder, with 0.08 cm in diameter and 0.45 cm long. To evaluate the absorbed dose distribution on the prostate, and other organs and tissues of an adult man, a male virtual anthropomorphic phantom MASH, coupled in the radiation transport code MCNPX 2.7.0, was employed.We simulated 75, 90 and 102 radioactive sources of 125 I and one of 192 Ir, inside the prostate, as normally used in these treatments, and each treatment was simulated separately. As this phantom was developed in a supine position, the displacement of the internal organs of the chest, compression of the lungs and reduction of the sagittal diameter were all taken into account. For the 192 Ir, the higher doses values were obtained for the prostate and surrounding organs, as the colon, gonads and bladder. Considering the 125 I sources, with photons with lower energies, the doses to organs that are far from the prostate were lower. All values for the dose rates are in agreement with those recommended for brachytherapy treatments. Besides that, the new seeds evaluated in this work present usefulness as a new tool in prostate brachytherapy treatments, and the methodology employed in this work may be applied for other radiation sources, or treatments. (authors)

  11. Study of two different radioactive sources for prostate brachytherapy treatment

    Energy Technology Data Exchange (ETDEWEB)

    Pereira Neves, Lucio; Perini, Ana Paula [Instituto de Fisica, Universidade Federal de Uberlandia, Caixa Postal 593, 38400-902, Uberlandia, MG (Brazil); Souza Santos, William de; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, IPENCNEN/SP, Av. Prof. Lineu Prestes, 2242, Cidade Universitaria, 05508-000 Sao Paulo, SP (Brazil); Belinato, Walmir [Departamento de Ensino, Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia, Campus Vitoria da Conquista, Zabele, Av. Amazonas 3150, 45030-220 Vitoria da Conquista, BA (Brazil)

    2015-07-01

    In this study we evaluated two radioactive sources for brachytherapy treatments. Our main goal was to quantify the absorbed doses on organs and tissues of an adult male patient, submitted to a brachytherapy treatment with two radioactive sources. We evaluated a {sup 192}Ir and a {sup 125}I radioactive sources. The {sup 192}Ir radioactive source is a cylinder with 0.09 cm in diameter and 0.415 cm long. The {sup 125}I radioactive source is also a cylinder, with 0.08 cm in diameter and 0.45 cm long. To evaluate the absorbed dose distribution on the prostate, and other organs and tissues of an adult man, a male virtual anthropomorphic phantom MASH, coupled in the radiation transport code MCNPX 2.7.0, was employed.We simulated 75, 90 and 102 radioactive sources of {sup 125}I and one of {sup 192}Ir, inside the prostate, as normally used in these treatments, and each treatment was simulated separately. As this phantom was developed in a supine position, the displacement of the internal organs of the chest, compression of the lungs and reduction of the sagittal diameter were all taken into account. For the {sup 192}Ir, the higher doses values were obtained for the prostate and surrounding organs, as the colon, gonads and bladder. Considering the {sup 125}I sources, with photons with lower energies, the doses to organs that are far from the prostate were lower. All values for the dose rates are in agreement with those recommended for brachytherapy treatments. Besides that, the new seeds evaluated in this work present usefulness as a new tool in prostate brachytherapy treatments, and the methodology employed in this work may be applied for other radiation sources, or treatments. (authors)

  12. Low dose rate brachytherapy (LDR-BT) as monotherapy for early stage prostate cancer in Italy: practice and outcome analysis in a series of 2237 patients from 11 institutions.

    Science.gov (United States)

    Fellin, Giovanni; Mirri, Maria A; Santoro, Luigi; Jereczek-Fossa, Barbara A; Divan, Claudio; Mussari, Salvatore; Ziglio, Francesco; La Face, Beniamino; Barbera, Fernando; Buglione, Michela; Bandera, Laura; Ghedi, Barbara; Di Muzio, Nadia G; Losa, Andrea; Mangili, Paola; Nava, Luciano; Chiarlone, Renato; Ciscognetti, Nunzia; Gastaldi, Emilio; Cattani, Federica; Spoto, Ruggero; Vavassori, Andrea; Giglioli, Francesca R; Guarneri, Alessia; Cerboneschi, Valentina; Mignogna, Marcello; Paoluzzi, Mauro; Ravaglia, Valentina; Chiumento, Costanza; Clemente, Stefania; Fusco, Vincenzo; Santini, Roberto; Stefanacci, Marco; Mangiacotti, Francesco P; Martini, Marco; Palloni, Tiziana; Schinaia, Giuseppe; Lazzari, Grazia; Silvano, Giovanni; Magrini, Stefano; Ricardi, Umberto; Santoni, Riccardo; Orecchia, Roberto

    2016-09-01

    Low-dose-rate brachytherapy (LDR-BT) in localized prostate cancer is available since 15 years in Italy. We realized the first national multicentre and multidisciplinary data collection to evaluate LDR-BT practice, given as monotherapy, and outcome in terms of biochemical failure. Between May 1998 and December 2011, 2237 patients with early-stage prostate cancer from 11 Italian community and academic hospitals were treated with iodine-125 ((125)I) or palladium-103 LDR-BT as monotherapy and followed up for at least 2 years. (125)I seeds were implanted in 97.7% of the patients: the mean dose received by 90% of target volume was 145 Gy; the mean target volume receiving 100% of prescribed dose (V100) was 91.1%. Biochemical failure-free survival (BFFS), disease-specific survival (DSS) and overall survival (OS) were estimated using Kaplan-Meier method. Log-rank test and multivariable Cox regression were used to evaluate the relationship of covariates with outcomes. Median follow-up time was 65 months. 5- and 7-year DSS, OS and BFFS were 99 and 98%, 94 and 89%, and 92 and 88%, respectively. At multivariate analysis, the National Comprehensive Cancer Network score (p LDR-BT. This first multicentre Italian report confirms LDR-BT as an excellent curative modality for low-/intermediate-risk prostate cancer. Multidisciplinary teams may help to select adequately patients to be treated with brachytherapy, with a direct impact on the implant quality and, possibly, on outcome.

  13. Red cell autoantibodies characterized by competitive inhibition of iodine 125 Rh alloantibody binding and by immunoprecipitation of membrane proteins

    International Nuclear Information System (INIS)

    Pierce, S.W.; Victoria, E.J.; Masouredis, S.P.

    1990-01-01

    The relationship between determinants recognized by warm-type immunoglobulin G red cell autoantibodies and the Rh antigens was characterized by autoantibody competitive inhibition of iodine 125 Rh alloantibody binding and autoantibody immunoprecipitation of iodine 125 red blood cell membrane proteins. The majority of blood donor autoantibody recognized epitopes that are closely related to Rh antigens as determined by competitive inhibition studies. Eighteen of 20 (90%) autoantibodies inhibited anti-Rh(c) binding, 15 inhibited anti-Rh(E), 5 inhibited anti-Rh(D), and only 2 failed to inhibit any of the three Rh alloantibodies tested. Autoantibodies that inhibited anti-Rh(D) also inhibited anti-Rh(c) and anti-Rh(E) and all those that inhibited anti-Rh(E) also inhibited anti-Rh(c). Autoantibodies that inhibited all three Rh alloantibodies immunoprecipitated 30 kd membrane polypeptides, as did two of the three autoantibodies that inhibited only anti-Rh(c) and anti-Rh(E). One autoantibody in this group and two autoantibodies that inhibited only anti-Rh(c), as well as an autoantibody that did not inhibit any of the Rh alloantibodies, immunoprecipitated only a single membrane polypeptide identified as band 3. The majority of normal donor red blood cell autoantibodies inhibited the binding of Rh alloantibodies, which indicates that they either bound to the Rh polypeptides or to epitopes on band 3 that were closely associated with the Rh complex

  14. Proceedings of the Second Congress of Radiochemotherapy and Brachytherapy and the Fifth Meeting of Medical Physics

    International Nuclear Information System (INIS)

    Zunino, Silvia; Venencia, Daniel; Martinez, Monica; Garrigo, Edgardo

    2009-01-01

    The Marie Curie Foundation in the city of Cordoba in Argentina, has organized the Second Congress of radiochemotherapy and brachytherapy and the Fifth Meeting of Medical Physics in order to collaborate with the scientific growth of radiation oncology and medical physics. The main topics covered were: patient's radioprotection, brachytherapy with iodine, radiation protection regulatory issues in Argentina, risk analysis in radiotherapy, medical radiation therapy, EPID dosimetry (Electronic Portal Image Device), accidents in radiotherapy, among others. [es

  15. Spectral CT imaging of vulnerable plaque with two independent biomarkers

    International Nuclear Information System (INIS)

    Baturin, Pavlo; Alivov, Yahya; Molloi, Sabee

    2012-01-01

    The purpose of this paper is to investigate the feasibility of a novel four-material decomposition technique for assessing the vulnerability of plaque with two contrast materials spectral computer tomography (CT) using two independent markers: plaque's inflammation and spotty calcification. A simulation study was conducted using an energy-sensitive photon-counting detector for k-edge imaging of the coronary arteries. In addition to detecting the inflammation status, which is known as a biological marker of a plaque's vulnerability, we use spotty calcium concentration as an independent marker to test a plaque's vulnerability. We have introduced a new method for detecting and quantifying calcium concentrations in the presence of two contrast materials (iodine and gold), calcium and soft tissue background. In this method, four-material decomposition was performed on a pixel-by-pixel basis, assuming there was an arbitrary mixture of materials in the voxel. The concentrations of iodine and gold were determined by the k-edge material decomposition based on the maximum likelihood method. The calibration curves of the attenuation coefficients, with respect to the concentrations of different materials, were used to separate the calcium signal from both contrast materials and different soft tissues in the mixtures. Three different materials (muscle, blood and lipid) were independently used as soft tissue. The simulations included both ideal and more realistic energy resolving detectors to measure the polychromatic photon spectrum in single slice parallel beam geometry. The ideal detector was used together with a 3 cm diameter digital phantom to demonstrate the decomposition method while a more realistic detector and a 33 × 24 cm 2 digital chest phantom were simulated to validate the vulnerability assessment technique. A 120 kVp spectrum was generated to produce photon flux sufficient for detecting contrast materials above the k-edges of iodine (33.2 keV) and gold (80.7 ke

  16. Airborne iodine-125 arising from surface contamination

    International Nuclear Information System (INIS)

    Kwok, C.S.; Hilditch, T.E.

    1982-01-01

    Measurements of airborne 125 I were made during the subdivision of 740 MBq stocks of 125 I iodide solution in a hospital dispensary. Within the fume cupboard the mean airborne 125 I concentration was 3.5 +- 2.9 kBqm -3 . No airborne concentration contamination was found outside the fume cupboard during these dispensing sessions. The airborne 125 I concentration arising from deliberate surface contamination (50 μl, 3.7-6.3 MBq) of the top of a lead pot was measured at a height simulating face level at an open work bench. There was a progressive fall in airborne concentration over seven days but even then the level was still significantly above background. Measurements made with the extraction system of the fume cupboard in operation were 2-3 times lower. (U.K.)

  17. A proteomics analysis for certain signature proteins of rabbit lacrimal passages after 125I seeds brachytherapy

    International Nuclear Information System (INIS)

    Li Dandan; Liu Lin; Gao Shi; Qi Liangchen; Ma Qingjie; Jin Longyun

    2010-01-01

    To search for certain signature proteins and the expression profiles in lacrimal passage stenosis, rabbit models of lacrimal passage stenosis were treated by 125 I seed brachytherapy. All the signature proteins were separated by two-dimensional electrophoresis, and identified by mass spectrometry. The results show that the up-regulated proteins are peptidyl-prolyl cis-trans isomerase A (PPIase A), and epidermal fatty acid-binding protein (E-FABP), while the down-regulated proteins are myosin light chain 1 (isomer of skeletal muscle), myosin light polypeptide 6 (isomer 1 of smooth muscle and non-muscle), myosin light chain 1 (isomer of slow-twitch muscle A), isomer 2 of ERC protein 2, and α-crystalline family protein. The proteins may play a role in healing the wound and regulating synaptic active zone of neurons due to correlation to cell apoptosis, proliferation and migration of smooth muscle cell. These provide molecular mechanism for preventing stenosis and restenosis of lacrimal passage. (authors)

  18. Volatilization of iodine from vegetation

    International Nuclear Information System (INIS)

    Amiro, B.D.; Johnston, F.L.

    1989-01-01

    Gaseous emissions of iodine were measured from bean plant foliage. A gamma-emitting iodine tracer, Na 125 I, was taken up by the plants from a hydroponic growth medium and released to a cuvette atmosphere. The dynamics of the flux were studied using a flow-through gamma detector. The relationship between leaf radioactive tracer activity and growth-medium activity was linear, as was the relationship between the iodine flux and both leaf and growth-medium activity. Iodine flux and leaf conductance to water responded similarly to changes in light levels, suggesting that the stomata may partially control the flux. The flux was inhibited by aeration of the hydroponic growth media, and we postulate that methylation causes the iodine flux. Iodine emissions from living vegetation probably contribute < 0.1% to the stable iodine concentration in the atmosphere above terrestrial areas. However, this pathway may be a direct route for radioactive iodine transport from contaminated soils to the atmosphere. (author)

  19. Volatilization of iodine from vegetation

    Energy Technology Data Exchange (ETDEWEB)

    Amiro, B D; Johnston, F L [Atomic Energy of Canada Ltd., Pinawa, MB (Canada). Whiteshell Nuclear Research Establishment

    1989-01-01

    Gaseous emissions of iodine were measured from bean plant foliage. A gamma-emitting iodine tracer, Na {sup 125}I, was taken up by the plants from a hydroponic growth medium and released to a cuvette atmosphere. The dynamics of the flux were studied using a flow-through gamma detector. The relationship between leaf radioactive tracer activity and growth-medium activity was linear, as was the relationship between the iodine flux and both leaf and growth-medium activity. Iodine flux and leaf conductance to water responded similarly to changes in light levels, suggesting that the stomata may partially control the flux. The flux was inhibited by aeration of the hydroponic growth media, and we postulate that methylation causes the iodine flux. Iodine emissions from living vegetation probably contribute < 0.1% to the stable iodine concentration in the atmosphere above terrestrial areas. However, this pathway may be a direct route for radioactive iodine transport from contaminated soils to the atmosphere. (author).

  20. Patterns of failure after iodine-125 seed implantation for prostate cancer

    International Nuclear Information System (INIS)

    Lamb, David S.; Greig, Lynne; Russell, Grant L.; Nacey, John N.; Broome, Kim; Studd, Rod; Delahunt, Brett; Iupati, Douglas; Jain, Mohua; Rooney, Colin; Murray, Judy; Lamb, Peter J.; Bethwaite, Peter B.

    2014-01-01

    Purpose: To determine the site of relapse when biochemical failure (BF) occurs after iodine-125 seed implantation for prostate cancer. Materials and methods: From 2001–2009, 500 men underwent implantation in Wellington, New Zealand. Men who sustained BF were placed on relapse guidelines that delayed restaging and intervention until the prostate-specific antigen (PSA) was ⩾20 ng/mL. Results: Most implants (86%) had a prostate D90 of ⩾90%, and multivariate analysis showed that this parameter was not a variable that affected the risk of BF. Of 21 BFs that occurred, the site of failure was discovered to be local in one case and distant in nine cases. Restaging failed to identify the site of relapse in two cases. In nine cases the trigger for restaging had not been reached. Conclusions: If post-implant dosimetry is generally within the optimal range, distant rather than local failure appears to be the main cause of BF. Hormone treatment is therefore the most commonly indicated secondary treatment intervention (STI). Delaying the start of STI prevents the unnecessary treatment of men who undergo PSA ‘bounce’ and have PSA dynamics initially mimicking those of BF

  1. 3-(/sup 125/I)iodo-4-hydroxyphenobarbitone for use in radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Mason, P.A.; Law, B. (Home Office Central Research Establishment, Aldermaston (UK))

    1982-03-01

    A method is described for the preparation of a barbiturate derivative, 3-iodo-4-hydroxyphenobarbitone, labelled with (/sup 125/I)iodine. The structure of the compound was confirmed by synthesis and purification of the (/sup 127/I)iodine derivative followed by mass spectral studies. The (/sup 125/I)iodine labelled barbiturate has proved to be chemically stable and has been shown to bind to a barbiturate antiserum. It should, therefore, prove to be very useful for the development of a radioimmunoassay for barbiturates.

  2. Validation of 125I-hCG as a marker for elimination of hCG and stability of 125I-hCG after in vivo injection in humans

    OpenAIRE

    Christensen, T B; Marqversen, J; Engbaek, F; Berger, P; Bacher, T; Maase, H von der

    1999-01-01

    We have recently introduced 125I-hCG as an elimination marker in patients with human chorionic gonadotrophin (hCG) producing testicular cancer. 125I-hCG is a well-known reagent in clinical biochemistry and is used extensively in hCG assays. Previous studies have shown that the iodination process leaves the hCG molecule mainly intact. The iodination, purification and stability of 125I-hCG tracer are described. The aim of the present study was to determine whether or not 125I is associated with...

  3. Development of a patient-reported questionnaire for collecting toxicity data following prostate brachytherapy

    International Nuclear Information System (INIS)

    Farnell, Damian J.J.; Mandall, Paula; Anandadas, Carmel; Routledge, Jaqueline; Burns, Meriel P.; Logue, John P.; Wylie, James P.; Swindell, Ric; Livsey, Jac; West, Catharine M.L.; Davidson, Susan E.

    2010-01-01

    Purpose: To improve a questionnaire used to collect patient-reported outcomes from patients with early stage prostate cancer treated with brachytherapy. A secondary aim was to adapt the Late Effects of Normal Tissue (LENT) subjective toxicity questionnaire for use to collect Common Terminology Criteria for Adverse Events (CTCAE) data, the current preferred platform for assessing radiation toxicity. Materials and methods: Three hundred and seventy-seven patients were treated with permanent iodine-125 seed implant brachytherapy for early prostate cancer. Toxicity data were collected before and at nine time points post-treatment (0-36 months). Compliance rates for patients completing individual items and item-subsection correlation coefficients were calculated. A factor analysis was carried out to analyse responses to the questionnaire and identify less informative questions, which could be removed. Cronbach's α coefficient was used to measure reliability. Results: Two thousand one hundred and eighty-eight questionnaires were analysed. There was poor compliance for questions specifically relating to operations and bowel medication. We found that the division of the questionnaire into subsections based on anatomical site was reasonable and that certain items could be safely removed. The high mean value for Cronbach's α across all questionnaires (0.752; 95% CI: 0.726-0.779) indicated that the questionnaire was reliable. Fifteen of the 44 questions were removed from the original questionnaires. Questions on urinary incontinence severity, management of urinary and bowel incontinence, effects of reduced flow of urine and the effects of symptoms on activity of daily living and change in sexual function were required to adapt the LENT subjective questionnaire for use to collect CTCAE data. Conclusions: A questionnaire, validated over 6 years to collect LENT subjective data were adapted and is a reliable approach for collecting CTCAE data after prostate brachytherapy.

  4. Microdosimetry of 125I and 3H in the cell nucleus

    International Nuclear Information System (INIS)

    Booz, J.; Fidorra, J.; Smit, T.; Charlton, D.E.

    1978-01-01

    The dosimetry and microdosimetry of iodine-125 and Tritium were analyzed. In particular, a detailed examination of the number and energies of the electrons emitted by iodine-125 was performed and the result considerably changed the currently available data. In this paper, the result of this examination will be summarized and the radiobiological implications will be discussed. A new model of the radiation mechanism of iodine-125 is proposed, which takes the high energy deposition at the molecular level and the high number of emitted Auger-electrons into consideration. On the basis of this model it is concluded that about 40 primary lesions are needed in the DNA for the cellular inactivation of T-cells. (orig./AJ) [de

  5. The use of iodinated standards for in vitro quantitative autoradiography with tritium-sensitive film

    International Nuclear Information System (INIS)

    Rostene, W.; Mourre, C.

    1985-01-01

    In the present study we developed iodinated 125 I-standards and tested the response of tritium-sensitive sheet film ( 3 H-Ultrofilm) to varying concentrations of 125 I prepared from brain ''paste'' mixed with mono-iodinated TiTx γ toxin. Results have practical implications since they allow quantitative measurements of autoradiograms obtained with 125 I-coordinats. An example is shown for 125 I-neurotensin binding sites on rat brain sections [fr

  6. Measurement of the increase in the capillary permeability in skin with Evans blue labelled with iodine-125 or 131

    International Nuclear Information System (INIS)

    Sugarava, S.; Goncalves, J.M.

    1976-01-01

    The quantitative evaluation of bradykinin and histamine with Evans blue labelled with iodine -125 or 131 is described. The activity upon vascular permeability was performed in the abdominal wall of rats injecting intravenously solution of labelled Evans blue and 0,1 ml of vasoactive drugs solution intradermally. Skin discs were cut with circular punch for external counting, quantitative results being compared with control discs. By using this method, satisfactory log dose-reponse curves were obtained for bradykinin and histamine that followed the general trend of S - shaped curves [pt

  7. First symposium seed implant 125I and high rate of prostate

    International Nuclear Information System (INIS)

    2012-01-01

    The First symposium seed implant 125 I and high rate of prostate, was organized by the Marie Curie Foundation, between the 12 to april 2012, in the Cordoba city of Argentina. In this event were presented several documents in different topics: patients selection for impacts of 125 I seeds; high doses radiation in radiotherapy; brachytherapy for prostate cancer; prostate implant technique with 125 I seeds; implant dosimetric aspects; radioprotection of 125 I seeds.

  8. [Technique of intraoperative planning in prostatic brachytherapy with permanent implants of 125I or 103Pd].

    Science.gov (United States)

    Prada Gómez, Pedro José; Juan Rijo, Germán; Hevia Suarez, Miguel; Abascal García, José María; Abascal García, Ramón

    2002-12-01

    Prostatic brachytherapy with permanent 125I or 123Pd seeds implantation is a therapeutic option for organ-confined prostate cancer. We analyze the technique based on previous planning, our current intraoperative planning procedure and the reasons that moved us to introduce this change. Changes in prostate volume and spatial localization observed between previous planning and intraoperative images, and possible difficulties for seed implantation due to pubic arch interference are some of the reasons that induce us to change technique. Before the operation, we calculate the prostatic volume by transrectal ultrasound; with this information we determine the total implant activity following Wu's nomogram, and per-seed activity; therefore, it is an individual process for each patient. We perform a peripheral implant, placing 75-80% of the seeds within the peripheral prostatic zone, generally through 12-15 needles, the rest of the seeds are placed in the central prostatic zone using a maximum of 3-4 needles in high volume prostates. The day of intervention, after positioning and catheter insertion, volumetry is re-checked. Ultrasound images (from base to apex every 5 mm) are transferred to the planner were a suitable seed distribution is determined. Implantation is then performed placing all needles unloaded, and then intraoperative post-planning to allow us to check implant precision is performed after cistoscopically check that there is no urethral or bladder penetration by any needle. We finish with the insertion of seeds into the prostate. Total time for the procedure is around 90 minutes. Intraoperative planning is an additional step for the treatment of prostate cancer with permanent seeds brachytherapy, which avoids the disadvantages of previous planning and improves tumor inclusion in the ideal irradiation dose area, which will translate into better local disease control.

  9. Rectourethral fistula following LDR brachytherapy.

    Science.gov (United States)

    Borchers, Holger; Pinkawa, Michael; Donner, Andreas; Wolter, Timm P; Pallua, Norbert; Eble, Michael J; Jakse, Gerhard

    2009-01-01

    Modern LDR brachytherapy has drastically reduced rectal toxicity and decreased the occurrence of rectourethral fistulas to <0.5% of patients. Therefore, symptoms of late-onset sequelae are often ignored initially. These fistulas cause severe patient morbidity and require interdisciplinary treatment. We report on the occurrence and management of a rectourethral fistula which occurred 4 years after (125)I seed implantation. Copyright 2009 S. Karger AG, Basel.

  10. Segmental Urethral Dosimetry and Urinary Toxicity in Patients With No Urinary Symptoms Before Permanent Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Thomas, Carys; Keyes, Mira; Liu, Mitchell; Moravan, Veronika

    2008-01-01

    Purpose: To determine whether segmental urethral dosimetry is predictive for the degree of urinary morbidity after prostate brachytherapy in patients with no urinary symptoms before prostate brachytherapy. Methods and Materials: Between May 2000 and November 2005, 1,107 patients underwent iodine-125 monotherapy with urethral sparing techniques. A total of 166 patients fulfilled the selection criteria: baseline (International Prostate Symptom Score) IPSS ≤5, no androgen deprivation therapy, and prostate ultrasound planning volumes (PUTV) <45 mL. The median follow-up was 44 months. Urinary morbidity was defined by maximum increase in IPSS, time to IPSS resolution, maximum Radiation Therapy Oncology Group (RTOG) score, time to RTOG resolution, and urinary retention. Surrogate deviated urethra was contoured and doses calculated at the base, mid-prostate, apex, and urogenital diaphragm. Univariate and multivariate analysis was used to evaluate urethral and prostate dosimetry, age, PUTV, and number of needles for their association with urinary morbidity. Results: Urethral dose was fairly constant in all urethra segments except prostate base, where the variation in does was large. On multivariate analysis, higher urethral base D50, V100, and larger PUTV were predictive for higher maximum increase in IPSS. Higher urethral base V100 and larger PUTV predicted for prolonged IPSS resolution. Higher urethral base D50 and larger needle number predicted for longer RTOG resolution. Higher urethral base V100 predicted for RTOG ≥2 toxicity. Conclusions: Radiation dose to the urethral base, larger PUTV, and needle number, predicted for increased urinary toxicity after prostate brachytherapy. Correlation between urinary morbidity and urethral base dosimetry may reflect a large variation in urethral dose observed at the prostate base

  11. Quantification of iodine in porous hydroxyapatite matrices for application as radioactive sources in brachytherapy

    OpenAIRE

    Lacerda, Kássio André; Lameiras, Fernando Soares; Silva, Viviane Viana

    2007-01-01

    In this study, non-radioactive iodine was incorporated in two types of biodegradable hydroxyapatite-based porous matrices (HA and HACL) through impregnation process from sodium iodine aqueous solutions with varying concentrations (0.5 and 1.0 mol/L) . The results revealed that both systems presented a high capacity of incorporating iodine into their matrices. The quantity of incorporated iodine was measured through Neutron Activation Analysis (NAA). The porous ceramic matrices based on hydrox...

  12. {sup 125}I brachytherapy in younger prostate cancer patients. Outcomes in low- and intermediate-risk disease

    Energy Technology Data Exchange (ETDEWEB)

    Kindts, Isabelle; Stellamans, Karin; Lambrecht, Antoon [AZ Groeninge Hospital, Department of Radiation Oncology, Kortrijk (Belgium); Billiet, Ignace [AZ Groeninge Hospital, Department of Urology, Kortrijk (Belgium); Pottel, Hans [Catholic University Leuven Kulak, Biostatistics, Faculty of Medicine, Kortrijk (Belgium)

    2017-09-15

    To evaluate local recurrence in younger men treated with low-dose-rate (LDR) {sup 125}I brachytherapy (BT) for localized prostate cancer. A total of 192 patients (≤65-years-old) were treated with LDR {sup 125}I-BT ± hormone therapy. Local failure was defined as any prostate-specific antigen (PSA) rise leading to salvage treatment or biochemical failure according to the Phoenix definition. A bounce was defined as a rise in the nadir of ≥0.2 ng/mL followed by spontaneous return. Proportions were compared using Fisher's exact tests; continuous variables using the unpaired t-test or its non-parametric equivalent. Cox proportional hazards models were applied for multivariable survival analysis. Median follow-up was 66 months. The 5-year local recurrence-free survival was 96.1%. Biopsy-proven local recurrence developed in 13 patients, 4 had a Phoenix-defined recurrence at the last follow-up. Androgen deprivation therapy was started in 1 patient without proven recurrence. Univariable risk factors for local recurrence were: at least 50% positive biopsies, intermediate risk, treatment with neoadjuvant hormone therapy, low preimplantation volume receiving 100% of the prescribed dose, and no bounce development. Hormone-naive patients not attaining a PSA value <0.5 ng/mL during follow-up also had a higher risk of local recurrences. Cox regression demonstrated that the variables ''at least 50% positive biopsies'' and ''bounce'' significantly impacted local failure (hazard ratio, HR 1.02 and 11.59, respectively). A bounce developed in 70 patients (36%). Younger patients and those treated with a lower activity per volume had a higher chance of developing a bounce in the Cox model (HR 0.99 and 0.04, respectively). For younger men, LDR BT is a valid primary curative treatment option in low-risk and is to consider in intermediate-risk localized prostate cancer. (orig.) [German] Bestimmung der Lokalrezidivrate bei juengeren Patienten

  13. Accurate estimation of dose distributions inside an eye irradiated with 106Ru plaques

    International Nuclear Information System (INIS)

    Brualla, L.; Sauerwein, W.; Sempau, J.; Zaragoza, F.J.; Wittig, A.

    2013-01-01

    Background: Irradiation of intraocular tumors requires dedicated techniques, such as brachytherapy with 106 Ru plaques. The currently available treatment planning system relies on the assumption that the eye is a homogeneous water sphere and on simplified radiation transport physics. However, accurate dose distributions and their assessment demand better models for both the eye and the physics. Methods: The Monte Carlo code PENELOPE, conveniently adapted to simulate the beta decay of 106 Ru over 106 Rh into 106 Pd, was used to simulate radiation transport based on a computerized tomography scan of a patient's eye. A detailed geometrical description of two plaques (models CCA and CCB) from the manufacturer BEBIG was embedded in the computerized tomography scan. Results: The simulations were firstly validated by comparison with experimental results in a water phantom. Dose maps were computed for three plaque locations on the eyeball. From these maps, isodose curves and cumulative dose-volume histograms in the eye and for the structures at risk were assessed. For example, it was observed that a 4-mm anterior displacement with respect to a posterior placement of a CCA plaque for treating a posterior tumor would reduce from 40 to 0% the volume of the optic disc receiving more than 80 Gy. Such a small difference in anatomical position leads to a change in the dose that is crucial for side effects, especially with respect to visual acuity. The radiation oncologist has to bring these large changes in absorbed dose in the structures at risk to the attention of the surgeon, especially when the plaque has to be positioned close to relevant tissues. Conclusion: The detailed geometry of an eye plaque in computerized and segmented tomography of a realistic patient phantom was simulated accurately. Dose-volume histograms for relevant anatomical structures of the eye and the orbit were obtained with unprecedented accuracy. This represents an important step toward an optimized

  14. The effectiveness of 125I seed interstitial brachytherapy for transplantation tumor of human pancreatic carcinoma in nude mice: an experiment in vivo

    International Nuclear Information System (INIS)

    Song Qi; Liu Yu; Wang Zhongmin; Huang Wei; Lu Jian; Chen Kemin

    2010-01-01

    Objective: To discuss the effectiveness and therapeutic mechanism of 125 I interstitial brachytherapy for transplantation tumor of human pancreatic carcinoma in nude mice. Methods: The human pancreatic cell line Sw1990 was subcutaneously injected into the right lower limb partially dorsal area next to the groin of the immunodeficient BABL /c nude mice. The tumor was removed and cut into small pieces after it was formed,then the tumor pieces were inoculated in nude mice. The tumor developed to 8-10 mm in size after six weeks. A total of 16 nude mice with the suitable tumor size were used in this study. The 16 experimental mice were randomly and equally divided into two groups. The mice in study group (n = 8) were implanted with 125 I seeds, while the mice in control group (n = 8) were implanted with ghost seeds. After the implantation both the long and short diameter of the tumors as well as the mouse body weight were measured every 4 days. The tumor weight was measured when the mouse was sacrificed. The paraffin-embedded samples were sent for histopathological examination. Apoptotic cells were checked with terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) method. Expression of proliferating cell nuclear antigen (PCNA) was detected with immuno-histochemical staining. Results: The tumor grew slowly in the study group, but rapidly in the control group. The tumor weight in the study group and the control group was (2.68 ± 0.70)g and (4.68 ± 1.45)g, respectively, the difference between two groups was statistically significant (P = 0.021). The tumor inhibition rate was about 42.66%. No significant difference in body weight of nude mice existed between two groups both before and after the treatment (P > 0.05). Marked tumor necrosis was seen in study group, but no obvious, or only a little, tumor necrosis could be observed in the control group. The apoptotic index checked with the TUENL method in the study group and control group was (23.2 ± 1.9)% and

  15. Development of irradiation support devices for production of brachytherapy seeds

    International Nuclear Information System (INIS)

    Mattos, Fabio R.; Rostelato, Maria Elisa C.M.; Zeituni, Carlos A.; Souza, Carla D.; Moura, Joao A.; Peleias Junior, Fernando S.; Karan Junior, Dib; Feher, Anselmo; Oliveira, Tiago B.; Benega, Marcos A.G.

    2013-01-01

    Ophthalmic tumors treatment with brachytherapy sources has been widely used as a primary or secondary therapy for non-malignant or malignant tumors, for example, choroid melanoma, and retinoblastoma. Ruthenium-106, Iodine-125, Palladium -103, Gold-198 and Iridium-192, are some radionuclides that can be applied for treatment of ocular tumors. These sources are in small sizes (a few millimeters) and different shapes (rods, wires, disks). To ensure high accuracy during treatment, they are positioned in eye applicators, specially designed to fit on the surface of tumor. The Nuclear and Energy Research Institute (IPEN/CNEN) in a partnership with Paulista Medicine School (UNIFESP) created a project that aims to develop a prototype of Iridium-192 seeds for treatment of eye cancer. This seed consists in a core of Ir -Pt alloy (20%-80%) with a length of 3 mm, to be activated in IPEN's IEA-R1 Reactor, and a titanium capsule sealing the core. It was imperative to develop a sustainer device for irradiation. This piece is used to avoid overlapping of one cores and, therefore, avoiding the 'shadow effect' that does not allow full activation of each core due to the high density. (author)

  16. Correlations of post-implant regional dosimetric parameters at 24 hours and one month, with clinical results of low-dose-rate brachytherapy for localized prostate cancer

    Directory of Open Access Journals (Sweden)

    Eiichiro Okazaki

    2017-12-01

    Full Text Available Purpose : To evaluate the correlations of post-implant regional dosimetrics at 24 hours (24 h and 1 month after implant procedures, with clinical outcomes of low-dose-rate (LDR brachytherapy for localized prostate cancer. Material and methods : Between January 2008 and December 2014, 130 consecutive patients treated for localized prostate cancer, receiving definitive iodine-125 ( 125 I brachytherapy treatment were retrospectively analyzed. All patients underwent post-implant CT imaging for dosimetric analysis at 24 h and 1 month after implantation procedure. Prostate contours were divided into quadrants: anterior-superior (ASQ, posterior-superior (PSQ, anterior-inferior (AIQ, and posterior-inferior (PIQ. Predictive factors and cut-off values of biochemical failure-free survival (BFFS and toxicities of LDR brachytherapy were analyzed. Results : The median follow-up time was 69.5 months. Seven patients (5.4% had biochemical failure. The 3-year and 5-year BFFS rates were 96.7% and 93.1%, respectively. On multivariate analysis, prostate-specific antigen and Gleason score were significant prognostic factors for biochemical failure. D 90 (the minimal dose received by 90% of the volume of PSQ and PIQ at 24 h, and D 90 of PSQ at 1 month were also significant factors. The cut-off values of PSQ D 90 were 145 Gy at 24 h and 160 Gy at 1 month. D 90 of the whole prostate was not significant at 24 h and at 1 month. D 90 of PSQ at 1 month was a significant factor for rectal hemorrhage. Conclusions : Post-implant D 90 of PSQ is significantly associated with BFFS for localized prostate cancer not only at 1 month, but also at 24 hours. D 90 of PSQ at 1 month is also a significant factor for rectal hemorrhage.

  17. Quantitative coronary plaque analysis predicts high-risk plaque morphology on coronary computed tomography angiography: results from the ROMICAT II trial.

    Science.gov (United States)

    Liu, Ting; Maurovich-Horvat, Pál; Mayrhofer, Thomas; Puchner, Stefan B; Lu, Michael T; Ghemigian, Khristine; Kitslaar, Pieter H; Broersen, Alexander; Pursnani, Amit; Hoffmann, Udo; Ferencik, Maros

    2018-02-01

    Semi-automated software can provide quantitative assessment of atherosclerotic plaques on coronary CT angiography (CTA). The relationship between established qualitative high-risk plaque features and quantitative plaque measurements has not been studied. We analyzed the association between quantitative plaque measurements and qualitative high-risk plaque features on coronary CTA. We included 260 patients with plaque who underwent coronary CTA in the Rule Out Myocardial Infarction/Ischemia Using Computer Assisted Tomography (ROMICAT) II trial. Quantitative plaque assessment and qualitative plaque characterization were performed on a per coronary segment basis. Quantitative coronary plaque measurements included plaque volume, plaque burden, remodeling index, and diameter stenosis. In qualitative analysis, high-risk plaque was present if positive remodeling, low CT attenuation plaque, napkin-ring sign or spotty calcium were detected. Univariable and multivariable logistic regression analyses were performed to assess the association between quantitative and qualitative high-risk plaque assessment. Among 888 segments with coronary plaque, high-risk plaque was present in 391 (44.0%) segments by qualitative analysis. In quantitative analysis, segments with high-risk plaque had higher total plaque volume, low CT attenuation plaque volume, plaque burden and remodeling index. Quantitatively assessed low CT attenuation plaque volume (odds ratio 1.12 per 1 mm 3 , 95% CI 1.04-1.21), positive remodeling (odds ratio 1.25 per 0.1, 95% CI 1.10-1.41) and plaque burden (odds ratio 1.53 per 0.1, 95% CI 1.08-2.16) were associated with high-risk plaque. Quantitative coronary plaque characteristics (low CT attenuation plaque volume, positive remodeling and plaque burden) measured by semi-automated software correlated with qualitative assessment of high-risk plaque features.

  18. Monte Carlo generation of dosimetric parameters for eye plaque dosimetry

    International Nuclear Information System (INIS)

    Cutajar, D.L.; Green, J.A.; Guatelli, S.; Rosenfeld, A.B.

    2010-01-01

    Full text: The Centre for Medical Radiation Physics have undertaken the dcvelopment of a quality assurance tool, using silicon pixelated detectors, for the calibration of eye plaques prior to insertion. Dosimetric software to correlate the measured and predicted dose rates has been constructed. The dosimetric parameters within the software, for both 1-125 and Ru-I 06 based eye plaques, were optimised using the Geant4 Monte Carlo toolkit. Methods For 1-125 based plaques, an novel application was developed to generate TG-43 parameters for any seed input. TG-43 parameters were generated for an Oncura model 6711 seed, with data points every millimetre up to 25 mm in the radial direction, and every 5 degrees in polar angle, and correlated to published data. For the Ru106 based plaques, an application was developed to generate dose rates about a Bebig model CCD plaque. Toroids were used to score the deposited dose, taking advantage of the cylindrical symmetry of the plaque, with radii in millimetre increments up to 25 mm, and depth from the plaque surface in millimetre increments up to 25 mm. Results TheTG43 parameters generated for the 6711 seed correlate well with published TG43 data at the given intervals, with radial dose function within 3%, and anisotropy function within 5% for angles greater than 30 degrees. The Ru-l 06 plaque data correlated well with the Bebig protocol of measurement. Conclusion Geant4 is a useful Monte Carlo tool for the generation of dosimetric data for eye plaque dosimetry. which may improve the quality assurance of eye plaque treatment. (author)

  19. Radiotracer experiments on the desorption of iodine from paddy soil with and without rice plants

    International Nuclear Information System (INIS)

    Muramatsu, Yasuyuki; Uchida, Shigeo; Yoshida, Satoshi

    1991-01-01

    In order to assess the behavior of radioiodine in rice fields, we have performed laboratory experiments, using 125 I tracer, on the desorption phenomena of iodine from soil during rice cultivation. Most of the 125 I added to the soil was adsorbed by the soil solid phase at the beginning of the experiment. However, the iodine started to desorb into the soil solution with the growth of rice plants. The highest desorption rate of iodine was found around the flowering period, i.e. nearly 30% of the 125 I was desorbed from Ando soil into the soil solution. In contrast to this, no particular increase in the iodine desorption was observed from the uncultivated flooded soil. It was suggested that rice plants had some influence upon iodine desorption from soil and the desorption also depended on the soil types. (author)

  20. Dose rate correction in medium dose rate brachytherapy for carcinoma cervix

    International Nuclear Information System (INIS)

    Patel, F.D.; Negi, P.S.; Sharma, S.C.; Kapoor, R.; Singh, D.P.; Ghoshal, S.

    1998-01-01

    Purpose: To establish the magnitude of brachytherapy dose reduction required for stage IIB and III carcinoma cervix patients treated by external radiation and medium dose rate (MDR) brachytherapy at a dose rate of 220±10 cGy/h at point A.Materials and methods: In study-I, at the time of MDR brachytherapy application at a dose rate of 220±10 cGy/h at point A, patients received either 3060 cGy, a 12.5% dose reduction (MDR-12.5), or 2450 cGy, a 30% dose reduction (MDR-30), to point A and they were compared to a group of previously treated LDR patients who received 3500 cGy to point A at a dose rate of 55-65 cGy/h. Study-II was a prospective randomized trial and patients received either 2450 cGy, a 30% dose reduction (MDR-II (30)) or 2800 cGy, a 20% dose reduction (MDR-II (20)), at point A. Patients were evaluated for local control of disease and morbidity. Results: In study-I the 5-year actuarial local control rate in the MDR-30 and MDR-12.5 groups was 71.7±10% and 70.5±10%, respectively, compared to 63.4±10% in the LDR group. However, the actuarial morbidity (all grades) in the MDR-12.5 group was 58.5±14% as against 34.9±9% in the LDR group (P 3 developed complication as against 62.5% of those receiving a rectal BED of (140 3 (χ 2 =46.43; P<0.001). Conclusion: We suggest that at a dose rate of 220±10 cGy/h at point A the brachytherapy dose reduction factor should be around 30%, as suggested by radiobiological data, to keep the morbidity as low as possible without compromising the local control rates. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  1. Preparation of directly iodinated steroid hormones and related directly halogenated compounds

    International Nuclear Information System (INIS)

    Sahadevan, V.

    1981-01-01

    The preparation of directly iodinated radioactive steroid hormones is described for use in radioimmunoassays or radiolocalization and treatment of human breast tumours. The radioactive iodinated steroid hormone is prepared by reacting a parent steroid hormone with an alkali metal iodide containing radioactive 123 I, 125 I, 130 I or 131 I in the presence of hydrogen peroxide or chloramine-T. The parent steroid hormones include the adrenal corticosteroids, the estrogens, the progestogens, the progestins and the diuretic and antidiuretic agents. The radioactive iodinated steroid hormone is prepared by iodinating the parent steroid hormone directly on the cyclopentanophenanthrene nucleus. The radioactive iodinated steroid hormones have the same antigenicity and receptor site specificity as the parent steroid hormone. The invention is illustrated by 1) the method of iodination of estradiol-17β, 2) results for the percentage labelling of several steroids and steroid hormones, 3) results for the radioimmunoassay of 125 I-estradiol and 4) results for the binding of directly iodinated estradiol-17β in an estrogen receptor assay of human breast cancer. (U.K.)

  2. Accurate estimation of dose distributions inside an eye irradiated with {sup 106}Ru plaques

    Energy Technology Data Exchange (ETDEWEB)

    Brualla, L.; Sauerwein, W. [Universitaetsklinikum Essen (Germany). NCTeam, Strahlenklinik; Sempau, J.; Zaragoza, F.J. [Universitat Politecnica de Catalunya, Barcelona (Spain). Inst. de Tecniques Energetiques; Wittig, A. [Marburg Univ. (Germany). Klinik fuer Strahlentherapie und Radioonkologie

    2013-01-15

    Background: Irradiation of intraocular tumors requires dedicated techniques, such as brachytherapy with {sup 106}Ru plaques. The currently available treatment planning system relies on the assumption that the eye is a homogeneous water sphere and on simplified radiation transport physics. However, accurate dose distributions and their assessment demand better models for both the eye and the physics. Methods: The Monte Carlo code PENELOPE, conveniently adapted to simulate the beta decay of {sup 106}Ru over {sup 106}Rh into {sup 106}Pd, was used to simulate radiation transport based on a computerized tomography scan of a patient's eye. A detailed geometrical description of two plaques (models CCA and CCB) from the manufacturer BEBIG was embedded in the computerized tomography scan. Results: The simulations were firstly validated by comparison with experimental results in a water phantom. Dose maps were computed for three plaque locations on the eyeball. From these maps, isodose curves and cumulative dose-volume histograms in the eye and for the structures at risk were assessed. For example, it was observed that a 4-mm anterior displacement with respect to a posterior placement of a CCA plaque for treating a posterior tumor would reduce from 40 to 0% the volume of the optic disc receiving more than 80 Gy. Such a small difference in anatomical position leads to a change in the dose that is crucial for side effects, especially with respect to visual acuity. The radiation oncologist has to bring these large changes in absorbed dose in the structures at risk to the attention of the surgeon, especially when the plaque has to be positioned close to relevant tissues. Conclusion: The detailed geometry of an eye plaque in computerized and segmented tomography of a realistic patient phantom was simulated accurately. Dose-volume histograms for relevant anatomical structures of the eye and the orbit were obtained with unprecedented accuracy. This represents an important step

  3. Exclusive curietherapy by permanent iodine-125 implants: selection of patients and results after eight years; Curietherapie exclusive par implants permanents d'iode-125: selection des patients et resultats a huit ans

    Energy Technology Data Exchange (ETDEWEB)

    Boutenbat, G.; Peiffert, D.; Bernier, V.; Moreau, J.L.; Boudran, G.; Noel, A.; Marchesi, V.; Huget, S. [Centre Alexis Vautrin, 54 - Vandoeuvre-Les-Nancy (France); Moreau, J.L. [Cabinet prive d' urologie, 54 - Nancy (France); Boudran, G. [Centre Hospitalier Universitaire de Brabois, 54 - Vandoeuvre-Les-Nancy (France)

    2010-10-15

    The authors report a retrospective study which assesses the results obtained over eight years and the toxicity of an exclusive curietherapy by permanent iodine-125 implants performed at the Nancy centre of struggle against cancer. More than five hundred patients have been treated between December 1999 and December 2007, a first group comprising patients suffering from a low risk cancer and a second group suffering from a medium risk cancer. The authors discuss the survival rates, the existence of side effects, and rectal toxicity results. Short communication

  4. Electronic brachytherapy management of atypical fibroxanthoma: report of 8 lesions

    Directory of Open Access Journals (Sweden)

    Stephen Doggett

    2017-01-01

    Full Text Available Purpose : To evaluate the suitability of treating atypical fibroxanthoma (AFX, an uncommon skin malignancy, with electronic brachytherapy. Material and methods : From Feb 2013 to Sep 2014, we were referred a total of 8 cases of AFX in 7 patients, all involving the scalp. All of them were treated with electronic brachytherapy 50 Kev radiations (Xoft Axxent®, Fremont, California. All lesions received 40 Gy in two fractions per week with 5mm margins. Results : At a median follow-up of 23.7 months, the local recurrence rate is 12.5%. The single lesion that failed was not debulked surgically prior to electronic brachytherapy. Conclusions : To our knowledge, this is the first report in the literature on the use of radiation therapy as curative primary treatment for AFX. No contraindication to the use of radiations is found in the literature, with surgery being the sole treatment for AFX noted. Our recurrence rate is 0% for debulked lesions. Risk of recurrence is mitigated with surgical debulking prior to brachytherapy. Electronic brachytherapy appears to be a safe and effective treatment for debulked AFX. Multiple excisions, skin grafting, and wound care can be avoided in elderly patients by the use of electronic brachytherapy.

  5. Investigating an organ-targeting platform based on hydroxyapatite nanoparticles using a novel in situ method of radioactive {sup 125}Iodine labeling

    Energy Technology Data Exchange (ETDEWEB)

    Ignjatović, Nenad [Centre for Fine Particles Processing and Nanotechnologies, Institute of Technical Sciences of the Serbian Academy of Science and Arts, Knez Mihailova 35/4, 11000 Belgrade (Serbia); Vranješ Djurić, Sanja [Laboratory for Radioisotopes, Vinča Institute of Nuclear Sciences, University of Belgrade, PO Box 522, 11001 Belgrade (Serbia); Mitić, Žarko [Faculty of Medicine, Department of Pharmacy, University of Niš, Bulevar dr Zorana Đinđića 81, 18000 Niš (Serbia); Janković, Drina [Laboratory for Radioisotopes, Vinča Institute of Nuclear Sciences, University of Belgrade, PO Box 522, 11001 Belgrade (Serbia); Uskoković, Dragan, E-mail: dragan.uskokovic@itn.sanu.ac.rs [Centre for Fine Particles Processing and Nanotechnologies, Institute of Technical Sciences of the Serbian Academy of Science and Arts, Knez Mihailova 35/4, 11000 Belgrade (Serbia)

    2014-10-01

    In this study, we have investigated the synthesis of nanoparticles of hydroxyapatite (HAp) and hydroxyapatite coated with chitosan (HAp/Ch) and the chitosan-poly-D,L-lactide-co-glycolide polymer blend (HAp/Ch-PLGA) as an organ-targeting system. We have examined and defined the final destination, as well as the dynamics and the pathways of the synthesized particles following intravenous administration in vivo. The XRD, ZP, FT-IR and SEM analyses have confirmed that the hydroxyapatite nanoparticles with d{sub 50} = 72 nm are coated with polymers. Radioactive 125-Iodine ({sup 125}I), a low energy gamma emitter, was used to develop a novel in situ method for the radiolabeling of particles and investigation of their biodistribution. {sup 125}I-labeled particles exhibited high stability in saline and serum over the second day, which justified their use in the following in vivo studies. The biodistribution of {sup 125}I-labeled particles after intravenous injection in rats differed significantly: HAp particles mostly targeted the liver, HAp/Ch the spleen and the liver, while HAp/Ch-PLGA targeted the lungs. Twenty-four hours post injection, HAp particles were excreted completely, while both {sup 125}I-HAp/Ch and {sup 125}I-HAp/Ch-PLGA were retained in the body for a prolonged period of time with more than 20% of radioactivity still found in different organs. - Highlights: • An organ-targeting carrier based on nano-hydroxyapatite • In situ labeling • Biodistribution of {sup 125}I-labeled HAp particles.

  6. Suppression of [sup 125]I-uptake in mouse thyroid by seaweed feeding; Possible preventative effect of dietary seaweed on internal radiation injury of the thyroid by radioactive iodine

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Hiroko; Yamamoto, Ichiro (Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Hygienic Sciences)

    1992-12-01

    We conducted an animal experiment to determine how dietary seaweeds rich in iodine and dietary fibers suppress radioactive iodine uptake by the thyroid, using mice and four kinds of experimental diets, three with 1% or 2% powdered fronds of the kelp Laminaria religiosa and 2% powdered laver Porphyra yezoensis, and one with cellulose. Iodine content of a hot-water extract of the kelp was 0.530[+-]0.001%, and its dietary fiber (DF) values were 52.8[+-]1.2%. Iodine in an extract of the laver was 0.008[+-]0.001%, and its DF values were 41.4%[+-]0.7%. A statistically significant reduction of [sup 125]I uptake by the thyroid, 3 hours after intragastric administration of the radionuclide at a dosage of 18.5 kBq or 185 kBq in 0.3 ml aqueous solution per mouse, was observed in mice previously fed the experimental diets containing 1% and 2% kelp during periods varying from 24 hours to 7 days. The degree of the suppression was observed to depend on the amount of iodine in the diet or in the injected sample, no matter whether organic or inorganic, judging from the results of an additional experiment. Thus, we conclude that previously fed iodine-rich material, especially dietary seaweeds rich in iodine and other minerals, vitamins, and [beta]-carotene, such as kelps or laver supplemented with inorganic iodine, may be effective in prevention of internal radiation injury of the thyroid. (author).

  7. More accurate fitting of 125I and 103Pd radial dose functions

    International Nuclear Information System (INIS)

    Taylor, R. E. P.; Rogers, D. W. O.

    2008-01-01

    In this study an improved functional form for fitting the radial dose functions, g(r), of 125 I and 103 Pd brachytherapy seeds is presented. The new function is capable of accurately fitting radial dose functions over ranges as large as 0.05 cm≤r≤10 cm for 125 I seeds and 0.10 cm≤r≤10 cm for 103 Pd seeds. The average discrepancies between fit and calculated data are less than 0.5% over the full range of fit and maximum discrepancies are 2% or less. The fitting function is also capable of accounting for the sharp increase in g(r) (upturn) seen for some sources for r 125 I seeds and 9 103 Pd seeds using the EGSnrc Monte Carlo user-code BrachyDose. Fitting coefficients of the new function are tabulated for all 27 seeds. Extrapolation characteristics of the function are also investigated. The new functional form is an improvement over currently used fitting functions with its main strength being the ability to accurately fit the rapidly varying radial dose function at small distances. The new function is an excellent candidate for fitting the radial dose function of all 103 Pd and 125 I brachytherapy seeds and will increase the accuracy of dose distributions calculated around brachytherapy seeds using the TG-43 protocol over a wider range of data. More accurate values of g(r) for r<0.5 cm may be particularly important in the treatment of ocular melanoma

  8. Permanent Seed Implant Dosimetry (PSID)TM 4.5 version as isodose and Treatment Planning System (TPS) programme for brachytherapy

    International Nuclear Information System (INIS)

    Indra Saptiama; Moch Subechi; Anung Pujiyanto; Hotman Lubis; Herlan Setiawan

    2014-01-01

    The medical treatment using radiation therapy for cancer diseases is increasingly developed. One of the method used in radiotherapy is brachytherapy. Brachytherapy is radiation therapy method in which a radiation source is implanted in cancer cell directly so the dose accepted by cancer cell is the highest dose and the dose accepted by normal cell is the lowest dose. I-125 Seed have been made successfully in domestic. To support the implant of I-125 seed for brachytherapy needs computer programme for the isodose calculation and Treatment Planning System (TPS). Permanent Seed Implant Dosimetry (PSID) 4.5 is one of the isodose calculation and Treatment Planning System (TPS) programme that is owned by Center for Radioisotope and Radiopharmaceutical-BATAN. In isodose calculation, PSID 4.5 uses 1D formalism and 2D formalism based on AAPM-TG43 (Association of American Physicist in Medicine- Task Group No.43). Anisotropic function on 1D formalism depend on distance function while on 2D formalism count on distance and angle function therefore 2D formalism has isodose calculation better than 1D formalism usage. PSID 4.5 can display the isodose contour of the seed I-125 radiation source in 2 dimension (2D) and 3 dimension (3D). The computer programme of isodose calculation and TPS uses PSID 4.5 is expected able to help planning for seed I-125 implantation process for brachytherapy that used by paramedics and to support the usage of seed I-125 as domestic product. (author)

  9. Preparation of sup 125 I-creatine phosphokinase-MM

    Energy Technology Data Exchange (ETDEWEB)

    Jingxian, Su; Jingmin, Ma [Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy

    1988-09-01

    {sup 125}I-creatine phosphokinase-MM ({sup 125}I-CPK-MM) was prepared by {sup 125}I-labelled Bolton-Hunter reagent (HPNS). Iodinating conditions of HPNS and its conjugation to protein were studied. {sup 125}I-CPK-MM with immune activity was obtained and used to establish the {sup 125}I-CPK-MM radioimmunoassay method by the General Hospital of PLA. {sup 125}I-CPK-MM in PBS-G solution containing 0.015 mol/l ethyl mercaptan at 4-10 deg C can be used for one month.

  10. Radio-guided occult lesion localisation using iodine-125 seeds ('ROLLIS') for removal of impalpable breast lesions: first Australian experience

    International Nuclear Information System (INIS)

    Taylor, Donna B.; Bourke, Anita G.; Westcott, Eliza

    2015-01-01

    Approximately one-third of breast cancers are impalpable and require pre-operative image-guided localisation. Hook-wire localisation (HWL) is commonly used but has several disadvantages. Use of a low-activity radioactive iodine-125 seed is a promising alternative technique used in the USA and the Netherlands. This pilot study describes the first use of this in Australia. In this prospective pilot study, 21 participants with biopsy-proven breast cancer underwent radio guided occult lesion localisation using iodine-125 seed(s) (ROLLIS) with insertion of a hook-wire for back up. Sentinel node biopsy was performed where indicated. Ease of hook-wire and seed insertion, duration of the procedure, dependence on the seed versus hook-wire during surgery, lesion location within the specimen, histopathology including size of radial margins, the ease of seed retrieval in pathology, and safe return of seeds for disposal were documented. Radiation dosimetry of staff was performed. All seeds were placed within 3.5 mm of the lesion. All lesions and seeds were removed. One participant needed re-excision for involved margins. Radiologists and surgeons both preferred ROLLIS. Surgeons were able to depend on the seed for localisation in all but one case. Sentinel node biopsy was successfully performed when required. Pathologists found seed retrieval quick and easy, with no detrimental effect on tissue processing. No radiation doses measurably above background were received by staff. ROLLIS is an easily learnt, safe and effective alternative technique to standard HWL.

  11. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: an electronic brachytherapy source.

    Science.gov (United States)

    Rivard, Mark J; Davis, Stephen D; DeWerd, Larry A; Rusch, Thomas W; Axelrod, Steve

    2006-11-01

    A new x-ray source, the model S700 Axxent X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, S700 Source exhibited depth dose behavior similar to low-energy photon-emitting low dose rate sources 125I and l03Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages.

  12. The Effect of Dose and Quality Assurance in Early Prostate Cancer Treated with Low Dose Rate Brachytherapy as Monotherapy.

    Science.gov (United States)

    Henry, A M; Rodda, S L; Mason, M; Musunuru, H; Al-Qaisieh, B; Bownes, P; Smith, J; Franks, K; Carey, B; Bottomley, D

    2015-07-01

    To examine the relationship between post-implant computed tomography dosimetry and long-term prostate-specific antigen relapse-free survival in patients treated with iodine 125 (I-125) low dose rate prostate brachytherapy as monotherapy and, second, to audit recent practice against Royal College of Radiologists' (RCR) guidelines after the re-introduction of post-implant dosimetry for all patients in our centre. Between March 1995 and September 2007, 2157 consecutive patients with localised prostate cancer underwent I-125 permanent prostate brachytherapy as monotherapy in a single UK centre. All patients were transrectal ultrasound planned delivering a 145 Gy (TG 43) minimum peripheral dose. None received supplemental external beam radiotherapy. Post-implant computed tomography-based dosimetry was undertaken between 4 and 6 weeks after treatment and was available for 711 (33%). Outcomes were analysed in terms of the relationship of D90 to prostate-specific antigen relapse-free survival (nadir 2+ definition) and all patients had a minimum follow-up of 5 years. For contemporary patients from 2011, quality metrics from post-implant computed tomography as defined by RCR guidelines are presented. A mean D90 of 138.7 Gy (standard deviation 24.7) was achieved for the historic cohort. Biochemical control at 10 years was 76% in patients with D90 > 140 Gy and 68% in those with D90 standard deviation) D90 has increased from 154 (15.3) Gy in 2011 to 164 (13.5) Gy in 2013. Similarly, an increase in the mean (standard deviation) V100 from 92 (4.4) to 95 (3.2) % is noted over time. No difference between clinicians was noted. D90 values of less than 140 Gy continue to be predictive of increased risk of recurrence of prostate cancer across risk groups with longer follow-up. Quality assurance can be used to ensure improved and consistent implant quality in a team with multiple clinicians. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights

  13. Assembly of a laboratory for calibration in brachytherapy. Comparison of responses with different instrumentation

    International Nuclear Information System (INIS)

    Pirchio, R.; Saravi, M.

    2006-01-01

    A common practice in quality control programs for dosimetry in brachytherapy is the source calibration. The AAPM (American Association of Physicists in Medicine) in the Task Group No. 40 (TG-40) it recommends that each institution that offers a brachytherapy service verifies the intensity of each source provided by the maker with secondary traceability. For such a reason it is necessary to have laboratories able to make calibrations of sources, traceable electrometer-chambers to primary or credited laboratories. The Regional Center of Reference of Dosimetry of the CNEA (National Commission of Atomic Energy) it is in the stage of finalization of the assembly of a Laboratory for source calibration and use equipment in brachytherapy. For it has two ionization chambers well type and two electrometers gauged by the Accredited Dosimetry Calibration Laboratory of the University of Wisconsin. Also account with a wide variety of supports and with a tube of 137 Cs pattern 3M model 6500/6D6C. The procedures for the calibration of sources and equipment were elaborated starting from the TECDOC-1274. On the other hand, its were carried out measurements with different instrumentation for the comparison of responses and at the same time to implement the calibration procedures. For it, its were used chambers and electrometers of the institution, of hospitals and of the national company 'Solydes'. In the measurements its were used seeds of 125 I taken place in Argentina and the tube of 137 Cs pattern mentioned previously. In first place it was proceeded to the determination of the center of the region of the plateau in the axial response for the seeds of Iodine-125 and the tube of Cesium-137 pattern using different chambers. Later on its were carried out measurements of accumulated loads during a certain interval of time in this position. The calibration factors of each chamber were determined, N Sk (μGy m 2 h -1 A -1 ), as the quotient of the kerma rate in reference air of the

  14. Radial dose functions for 103Pd, 125I, 169Yb and 192Ir brachytherapy sources: an EGS4 Monte Carlo study

    International Nuclear Information System (INIS)

    Mainegra, E.

    2000-01-01

    Radial dose functions g(r) in water around 103 Pd, 125 I, 169 Yb and 192 Ir brachytherapy sources were estimated by means of the EGS4 simulation system and extensively compared with experimental as well as with theoretical results. The DLC-136/PHOTX cross section library, water molecular form factors, bound Compton scattering and Doppler broadening of the Compton-scattered photon energy were considered in the calculations. Use of the point source approach produces reasonably accurate values of the radial dose function only at distances beyond 0.5 cm for 103 Pd sources. It is shown that binding corrections for Compton scattering have a negligible effect on radial dose function for 169 Yb and 192 Ir seeds and for 103 Pd seeds under 5.0 cm from the source centre and for the 125 I seed model 6702 under 8.0 cm. Beyond those limits there is an increasing influence of binding corrections on radial dose function for 103 Pd and 125 I sources. Results in solid water medium underestimate radial dose function for low-energy sources by as much as 6% for 103 Pd and 2.5% for 125 I already at 2 cm from source centre resulting in a direct underestimation of absolute dose rate values. It was found necessary to consider medium boundaries when comparing results for the radial dose function of 169 Yb and 192 Ir sources to avoid discrepancies due to the backscattering contribution in the phantom medium. Values of g(r) for all source types studied are presented. Uncertainties lie under 1% within one standard deviation. (author)

  15. The side effects and complications of percutaneous iodine-125 seeds implantation under CT-guide for patients with advanced pancreatic cancer.

    Science.gov (United States)

    Lv, Wei-Fu; Lu, Dong; Xiao, Jing-Kun; Mukhiya, Gauri; Tan, Zhong-Xiao; Cheng, De-Lei; Zhou, Chun-Ze; Zhang, Xing-Min; Zhang, Zheng-Feng; Hou, Chang-Long

    2017-12-01

    The present study investigates the side effects and complications of computed tomography (CT)-guided percutaneous iodine-125 (I-125) seeds implantation for advanced pancreatic cancer. The clinical data were retrospectively analyzed for patients treated with implantation of I-125 seeds under CT-guide in our hospital from May 2010 to April 2015. The side effects and complications were collected and their possible reasons were analyzed. A total of 78 patients were enrolled. The side effects were categorized as fever in 29 cases (37.18%), abdominal pain in 26 cases (33.33%), nausea and vomiting in 9 cases (11.54%), diarrhea in 5 cases (6.41%), and constipation in 4 cases (5.13%). Complications were composed of pancreatitis in 9 cases (11.54%), infection in 5 cases (6.41%), seed migration in 2 cases (2.56%), intestinal perforation in 1 case (1.28%), and intestinal obstruction in 1 case. The incidence of complication was 23.08% (18/78). The difference in incidence of complication was statistically significant between patients implanted with ≤27 seeds and those with >27 seeds (P = .032). The side effects and complications frequently occur in implantation of I-125 seeds for patients with advanced pancreatic cancer. More concern should be given to the patients treated by this technique. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  16. Tri-Modality therapy with I-125 brachytherapy, external beam radiation therapy, and short- or long-term hormone therapy for high-risk localized prostate cancer (TRIP: study protocol for a phase III, multicenter, randomized, controlled trial

    Directory of Open Access Journals (Sweden)

    Konaka Hiroyuki

    2012-03-01

    Full Text Available Abstract Background Patients with high Gleason score, elevated prostate specific antigen (PSA level, and advanced clinical stage are at increased risk for both local and systemic relapse. Recent data suggests higher radiation doses decrease local recurrence and may ultimately benefit biochemical, metastasis-free and disease-specific survival. No randomized data is available on the benefits of long-term hormonal therapy (HT in these patients. A prospective study on the efficacy and safety of trimodality treatment consisting of HT, external beam radiation therapy (EBRT, and brachytherapy (BT for high-risk prostate cancer (PCa is strongly required. Methods/Design This is a phase III, multicenter, randomized controlled trial (RCT of trimodality with BT, EBRT, and HT for high-risk PCa (TRIP that will investigate the impact of adjuvant HT following BT using iodine-125 (125I-BT and supplemental EBRT with neoadjuvant and concurrent HT. Prior to the end of September 2012, a total of 340 patients with high-risk PCa will be enrolled and randomized to one of two treatment arms. These patients will be recruited from more than 41 institutions, all of which have broad experience with 125I-BT. Pathological slides will be centrally reviewed to confirm patient eligibility. The patients will commonly undergo 6-month HT with combined androgen blockade (CAB before and during 125I-BT and supplemental EBRT. Those randomly assigned to the long-term HT group will subsequently undergo 2 years of adjuvant HT with luteinizing hormone-releasing hormone agonist. All participants will be assessed at baseline and every 3 months for the first 30 months, then every 6 months until 84 months from the beginning of CAB. The primary endpoint is biochemical progression-free survival. Secondary endpoints are overall survival, clinical progression-free survival, disease-specific survival, salvage therapy non-adaptive interval, and adverse events. Discussion To our knowledge, there have

  17. Radioiodine labelled SP-4 as an imaging agent for atherosclerotic plaques

    International Nuclear Information System (INIS)

    Zhang Yongxue; Wu Zhijian; Cao Wei

    2000-01-01

    The clinical prospect of radioiodinated SP-4 as an atherosclerotic plaque imaging agent was studied. The SP-4 was synthesized by a solid phase method and identified by an amino acid analysis after purification with HPLC. SP-4 was labelled with 131 I and 125 I by the Chloramine-T method and purified through Sephadex G-25 column. Twelve New Zealand rabbits were divided into an atherosclerotic group (n = 7, AR) and a control group (n = 5, NR). All of the atherosclerotic rabbits were intravenous administrated with bovine serum albumin, then feb with high cholesterol and fat diet. 125 I-SP-4 was intravenous administrated to the rabbits of both groups. The biodistribution of 125 I-SP-4 in rabbits was investigated. The uptakes (% ID/g) in blood and thoracic aorta and abdominal aorta were calculated 4 hours postinjection. Macro-autoradiography and micro-autoradiography were performed in 2 AR atherosclerotic abdominal aortas. The clearance of radioactivity from plasma was very rapid. 125 I-SP-4 was mainly excreted through kidneys. The radioactive uptakes of abdominal aorta and thoracic aorta of AR at 4 hours postinjection were significantly higher than that of NR. The films of macro-autoradiography showed focal accumulation of the radioactivity in the areas of a newly formed edges of atherosclerotic plaques. On the slices of micro-autoradiography, the obvious radioactive accumulation could be found in the atherosclerotic plaques. Thus it was seen that the SP-4 remained its biological activity after radioiodination and was located at atherosclerotic lesions, it is potentially useful as an atherosclerotic plaque imaging agent

  18. Development of irradiation support devices for production of brachytherapy seeds

    Energy Technology Data Exchange (ETDEWEB)

    Mattos, Fabio R.; Rostelato, Maria Elisa C.M.; Zeituni, Carlos A.; Souza, Carla D.; Moura, Joao A.; Peleias Junior, Fernando S.; Karan Junior, Dib; Feher, Anselmo; Oliveira, Tiago B.; Benega, Marcos A.G., E-mail: tiagooliveira298@gmail.com, E-mail: mattos.fr@gmail.com, E-mail: elisaros@ipen.br, E-mail: czeituni@ipen.br, E-mail: carladdsouza@yahoo.com.br, E-mail: jamoura@ipen.br, E-mail: ernandopeleias@gmail.com, E-mail: s, E-mail: dib.karan@usp.br, E-mail: afeher@ipen.br, E-mail: marcosagbenega@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Ophthalmic tumors treatment with brachytherapy sources has been widely used as a primary or secondary therapy for non-malignant or malignant tumors, for example, choroid melanoma, and retinoblastoma. Ruthenium-106, Iodine-125, Palladium -103, Gold-198 and Iridium-192, are some radionuclides that can be applied for treatment of ocular tumors. These sources are in small sizes (a few millimeters) and different shapes (rods, wires, disks). To ensure high accuracy during treatment, they are positioned in eye applicators, specially designed to fit on the surface of tumor. The Nuclear and Energy Research Institute (IPEN/CNEN) in a partnership with Paulista Medicine School (UNIFESP) created a project that aims to develop a prototype of Iridium-192 seeds for treatment of eye cancer. This seed consists in a core of Ir -Pt alloy (20%-80%) with a length of 3 mm, to be activated in IPEN's IEA-R1 Reactor, and a titanium capsule sealing the core. It was imperative to develop a sustainer device for irradiation. This piece is used to avoid overlapping of one cores and, therefore, avoiding the 'shadow effect' that does not allow full activation of each core due to the high density. (author)

  19. EchoSeed Model 6733 Iodine-125 brachytherapy source: Improved dosimetric characterization using the MCNP5 Monte Carlo code

    Energy Technology Data Exchange (ETDEWEB)

    Mosleh-Shirazi, M. A.; Hadad, K.; Faghihi, R.; Baradaran-Ghahfarokhi, M.; Naghshnezhad, Z.; Meigooni, A. S. [Center for Research in Medical Physics and Biomedical Engineering and Physics Unit, Radiotherapy Department, Shiraz University of Medical Sciences, Shiraz 71936-13311 (Iran, Islamic Republic of); Radiation Research Center and Medical Radiation Department, School of Engineering, Shiraz University, Shiraz 71936-13311 (Iran, Islamic Republic of); Comprehensive Cancer Center of Nevada, Las Vegas, Nevada 89169 (United States)

    2012-08-15

    This study primarily aimed to obtain the dosimetric characteristics of the Model 6733 {sup 125}I seed (EchoSeed) with improved precision and accuracy using a more up-to-date Monte-Carlo code and data (MCNP5) compared to previously published results, including an uncertainty analysis. Its secondary aim was to compare the results obtained using the MCNP5, MCNP4c2, and PTRAN codes for simulation of this low-energy photon-emitting source. The EchoSeed geometry and chemical compositions together with a published {sup 125}I spectrum were used to perform dosimetric characterization of this source as per the updated AAPM TG-43 protocol. These simulations were performed in liquid water material in order to obtain the clinically applicable dosimetric parameters for this source model. Dose rate constants in liquid water, derived from MCNP4c2 and MCNP5 simulations, were found to be 0.993 cGyh{sup -1} U{sup -1} ({+-}1.73%) and 0.965 cGyh{sup -1} U{sup -1} ({+-}1.68%), respectively. Overall, the MCNP5 derived radial dose and 2D anisotropy functions results were generally closer to the measured data (within {+-}4%) than MCNP4c and the published data for PTRAN code (Version 7.43), while the opposite was seen for dose rate constant. The generally improved MCNP5 Monte Carlo simulation may be attributed to a more recent and accurate cross-section library. However, some of the data points in the results obtained from the above-mentioned Monte Carlo codes showed no statistically significant differences. Derived dosimetric characteristics in liquid water are provided for clinical applications of this source model.

  20. Determination of iodide, iodate and organo-iodine in waters with a new total organic iodine measurement approach.

    Science.gov (United States)

    Gong, Tingting; Zhang, Xiangru

    2013-11-01

    The dissolved iodine species that dominate aquatic systems are iodide, iodate and organo-iodine. These species may undergo transformation to one another and thus affect the formation of iodinated disinfection byproducts during disinfection of drinking waters or wastewater effluents. In this study, a fast, sensitive and accurate method for determining these iodine species in waters was developed by derivatizing iodide and iodate to organic iodine and measuring organic iodine with a total organic iodine (TOI) measurement approach. Within this method, organo-iodine was determined directly by TOI measurement; iodide was oxidized by monochloramine to hypoiodous acid and then hypoiodous acid reacted with phenol to form organic iodine, which was determined by TOI measurement; iodate was reduced by ascorbic acid to iodide and then determined as iodide. The quantitation limit of organo-iodine or sum of organo-iodine and iodide or sum of organo-iodine, iodide and iodate was 5 μg/L as I for a 40 mL water sample (or 2.5 μg/L as I for an 80 mL water sample, or 1.25 μg/L as I for a 160 mL water sample). This method was successfully applied to the determination of iodide, iodate and organo-iodine in a variety of water samples, including tap water, seawater, urine and wastewater. The recoveries of iodide, iodate and organo-iodine were 91-109%, 90-108% and 91-108%, respectively. The concentrations and distributions of iodine species in different water samples were obtained and compared. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Iodine-123 program at the TRIUMF laboratory

    International Nuclear Information System (INIS)

    Vincent, J.S.

    1985-01-01

    A research program for the production and utilization of iodine-123 is described. From 1979 to 1982 the spallation of elemental cesium by 500-MeV protons was used to provide 100 mCi/hr at the end of bombardment (EOB). Contaminants were 3% iodine-125 and 0.15% tellurium-121 at EOB + 36 hr. The material from weekly runs was used by remote clinics in Canada for evaluation as a radiochemical and for labeling studies. A new facility at TRIUMF will be operational in 1983 to produce iodine-123 by the (p,5n) reaction

  2. Effect of edema, relative biological effectiveness, and dose heterogeneity on prostate brachytherapy

    International Nuclear Information System (INIS)

    Wang, Jian Z.; Mayr, Nina A.; Nag, Subir; Montebello, Joseph; Gupta, Nilendu; Samsami, Nina; Kanellitsas, Christos

    2006-01-01

    Many factors influence response in low-dose-rate (LDR) brachytherapy of prostate cancer. Among them, edema, relative biological effectiveness (RBE), and dose heterogeneity have not been fully modeled previously. In this work, the generalized linear-quadratic (LQ) model, extended to account for the effects of edema, RBE, and dose heterogeneity, was used to assess these factors and their combination effect. Published clinical data have shown that prostate edema after seed implant has a magnitude (ratio of post- to preimplant volume) of 1.3-2.0 and resolves exponentially with a half-life of 4-25 days over the duration of the implant dose delivery. Based on these parameters and a representative dose-volume histogram (DVH), we investigated the influence of edema on the implant dose distribution. The LQ parameters (α=0.15 Gy -1 and α/β=3.1 Gy) determined in earlier studies were used to calculate the equivalent uniform dose in 2 Gy fractions (EUD 2 ) with respect to three effects: edema, RBE, and dose heterogeneity for 125 I and 103 Pd implants. The EUD 2 analysis shows a negative effect of edema and dose heterogeneity on tumor cell killing because the prostate edema degrades the dose coverage to tumor target. For the representative DVH, the V 100 (volume covered by 100% of prescription dose) decreases from 93% to 91% and 86%, and the D 90 (dose covering 90% of target volume) decrease from 107% to 102% and 94% of prescription dose for 125 I and 103 Pd implants, respectively. Conversely, the RBE effect of LDR brachytherapy [versus external-beam radiotherapy (EBRT) and high-dose-rate (HDR) brachytherapy] enhances dose effect on tumor cell kill. In order to balance the negative effects of edema and dose heterogeneity, the RBE of prostate brachytherapy was determined to be approximately 1.2-1.4 for 125 I and 1.3-1.6 for 103 Pd implants. These RBE values are consistent with the RBE data published in the literature. These results may explain why in earlier modeling studies

  3. Synthesis and binding of [125I2]philanthotoxin-343, [125I2]philanthotoxin-343-lysine, and [125I2]philanthotoxin-343-arginine to rat brain membranes

    International Nuclear Information System (INIS)

    Goodnow, R.A. Jr.; Bukownik, R.; Nakanishi, K.; Usherwood, P.N.; Eldefrawi, A.T.; Anis, N.A.; Eldefrawi, M.E.

    1991-01-01

    125I2-iodinated philanthotoxin-343 (PhTX-343), [125I2]PhTX-343-arginine, and [125I2]PhTX-343-lysine were synthesized and evaluated as probes for glutamate receptors in rat brain synaptic membranes. It was found that these probes were not specific for the glutamate receptors but may be useful for investigating the polyamine binding site. Filtration assays with Whatman GF/B fiber glass filters were unsuitable because the iodinated PhTX-343 analogues exhibited high nonspecific binding to the filters, thus hindering detection of specific binding to membranes. When binding was measured by a centrifugal assay, [125I2]PhTX-343-lysine bound with low affinity (KD = 11.4 ± 2 microM) to a large number of sites (37.2 ± 9.1 nmol/mg of protein). The binding of [125I2]PhTX-343-lysine was sensitive only to the polyamines spermine and spermidine, which displaced [125I2]PhTX-343-lysine with Ki values of (3.77 ± 1.4) x 10(-5) M and (7.51 ± 0.77) x 10(-5) M, respectively. The binding was insensitive to glutamate receptor agonists and antagonists. Binding results with [125I2]PhTX-343-arginine were similar to those of [125I2]-PhTX-343-lysine. Considering the high number of toxin binding sites (10000-fold more than glutamate) in these membranes and the insensitivity of the binding to almost all drugs that bind to glutamate receptors, it is evident that most of the binding observed is not to glutamate receptors. On the other hand, PhTX analogues with photoaffinity labels may be useful in the isolation/purification of various glutamate and nicotinic acetylcholine receptors; they could also be useful in structural studies of receptors and their binding sites

  4. Daya antibakteri obat kumur chlorhexidine, povidone iodine, fluoride suplementasi zinc terhadap, Streptococcus mutans dan Porphyromonas gingivalis (Antibacterial effect of mouth washes containing chlorhexidine, povidone iodine, fluoride plus zinc on Strep

    Directory of Open Access Journals (Sweden)

    Betadion Rizki Sinaredi

    2014-12-01

    Full Text Available Background: Dental Caries and periodontal disease prevalence in Indonesian children are still high. Some efforts can be done to overcome the problem; one of them is the use of mouthwash to decrease pathogen microorganisms. The mouthwashes that commercially available in market are chlorhexidine, povidone Iodine and Fluoride with Zinc supplementation. Purpose: The purpose of this study was to examine the anti bacterial effect of the mouthwashes chlorhexidine, povidone iodine and fluoride with zinc supplementation against mix bacteria that found in the plaque, Streptococcus mutans and Porphyromonas gingivalis. Methods: The antibacterial effect was measured using disk diffusion test. The bacteria samples (plaque polybacteria, S.mutans and P. gingivalis were inoculated and spread in the petridish containing MHA. Paper discs containing the mouthwashes were placed in the petridish and incubated for 24 hours at 37oC (anaerobe for P. gingivalis, aerobe for S. mutans and polybacteria. The diameter of inhibition zone surrounding the paper discs were measured and compared between each active ingredient contained in mouthwash. Results: Chlorhexidine had the strongest antibacterial effect than povidone iodine and fluoride. Chlorhexidine was more effective to inhibited the growth of S. mutans than to polybacteria or P.Gingivalis, while Povidone iodine and fluoride were more effective to inhibited the growth of polybacteria. Conclusion: The mouthwash chlorhexidine was more effective to inhibit the growth of plaque polybacteria, Streptoccous mutans and Porphyromonas gingivalis compared with povidone iodine and fluoride with zinc supplementation.Latar belakang: Prevalensi karies gigi dan penyakit periodontal masih tinggi pada anak Indonesia. Usaha mengatasi hal tersebut antara lain melalui melalui penggunaan obat kumur untuk mengurangi jumlah kuman pathogen. Kandungan obat kumur yang beredar di pasar diantaranya adalah chlorhexidine, povidone iodine dan fluoride

  5. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: An electronic brachytherapy source

    International Nuclear Information System (INIS)

    Rivard, Mark J.; Davis, Stephen D.; DeWerd, Larry A.; Rusch, Thomas W.; Axelrod, Steve

    2006-01-01

    A new x-ray source, the model S700 Axxent trade mark sign X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, P (5) were 0.20, 0.24, and 0.29 for the 40, 45, and 50 kV voltage settings, respectively. For 1 125 I and 103 Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages

  6. LOW POWER BRACHYTHERAPY IN COMBINED TREATMENT IN PATIENTS WITH INTERMEDIATE RISK OF LOCALIZED PROST ATE CANCER

    Directory of Open Access Journals (Sweden)

    V. A. Biryukov

    2014-01-01

    Full Text Available Objective. Estimation of the effectiveness of low power brachytherapy sources I-125 in the combined treatment in group of patients of intermediate risk of localized prostate cancer.Material and methods. The study included 126 patients with prostate cancer of intermediate risk. 104 patients (83,9% were conducted low power brachytherapy I‑125 in combination with hormone therapy by analogues of LHWG. 22 patients (16.1% received external beam irradiation in combination with brachytherapy I‑125 and hormonal treatment. Relapse-free survival of patients was evaluated in accordance with the criteria Phoenix (Nadir PSA + ng/ml. Evaluation of side effects of radiation treatment were carried out according to the RTOG criteria.Results. PSA relapse-free survival in the group of brachytherapy and hormone treatment at the time of observation 5 years amounted to 97.1%. In the group of combined radiation therapy with brachytherapy, and hormonal treatment PSA relapse-free survival rate was 95.5%.In both groups, relapse-free survival was noted in 96,8% of cases. Tumor-specific and overall survival in bothgroups was 100%. The major complications of treatment in both groups were radiation urethritis 1 to 2 degrees in 9.5% of cases (12 patients, urethral stricture in 5 patients (3.9% of cases, acute urinary retention in 1 patient (0.8% of cases and late radiation rectitis of 2 degree in 1.58% of cases (2 patients.Conclusions. It is possible to draw tentative conclusions about the high rate of survival without progression in both treatment groups on the background of the relatively low frequency of adverse reactions. It is necessary further follow-up for patients with estimating of survival for a longer period.

  7. Relation of immediate and delayed thallium-201 distribution to localization of iodine-125 antimyosin antibody in acute experimental myocardial infarction

    International Nuclear Information System (INIS)

    Khaw, B.A.; Strauss, H.W.; Pohost, G.M.; Fallon, J.T.; Katus, H.A.; Haber, E.

    1983-01-01

    Thallium-201 (TI-201) distribution in acute experimental myocardial infarction (MI) (n . 18) was compared with cardiac-specific antimyosin Fab (AM-Fab) uptake, a specific marker for myocardial necrosis. When antimyosin was injected 4 hours after ligation with TI-201 administered 23 hours 55 minutes later and measurement of myocardial distribution determined 5 minutes after intravenous administration of TI-201, (1) TI-201 distribution closely correlated with microsphere regional blood flow, and (2) an inverse exponential relation to iodine-125 (I-125) AM-Fab uptake was apparent. In another group of 4 animals, TI-201 and AM-Fab were administered intravenously 4 hours after MI, and 36 hours later myocardial distribution was measured. This delayed TI-201 distribution had a close inverse linear correlation with I-125 AM-Fab uptake. This inverse linear relation also was apparent in 28-hour-old MIs in dogs (n . 4) where collateral circulation had been established. TI-201 was administered intravenously at 27 hours after MI, and TI-201 distribution was determined 1 hour later. The present study demonstrated that whereas immediate TI-201 distribution is flow-limited, delayed TI-201 distribution is a marker of cell viability which, due to prolonged circulation time and redistribution, is not flow-limited

  8. Balloon brachytherapy for brain tumor-radiation safety experiences at the University of Medicine and Dentistry of New Jersey.

    Science.gov (United States)

    Lanka, Venkata K

    2006-11-01

    Balloon brachytherapy is a technique for the removal of a brain tumor in which an inflatable balloon is placed in a resection cavity and then filled with liquid I, delivering low energy dose to the cancerous cells surrounding the cavity. After preparing a patient room to mitigate any spills or contamination, liquid 125I (Iotrex) was assayed with a dose calibrator and injected into the balloon placed in the patient's brain. Approximately 98.6% of the isotope was recovered at the end of the procedure. Approximately 1.4% remained unrecovered and is assumed to have diffused through the balloon membrane. Each day, the patient's urine was collected and the total urine activity measured was less than 7% of the unrecovered activity. The remainder of the unrecovered activity was not evaluated. It was assumed to be distributed in the patient's body, and a tiny quantity of liquid spilled from an IV line while injecting. Training was conducted for radiation oncologists, neurosurgeons, and participating residents regarding balloon brachytherapy radiation safety precautions. Precautions during treatment included safe handling of body fluids. General radiation safety precautions and nursing care instructions were posted on the patient door. Air monitoring was conducted to detect any airborne iodine. At the time of balloon removal, the radiation safety department monitored the operating room and staff for contamination. Waste, including the balloon, was held for decay on site prior to disposal.

  9. Production techniques and quality control of sealed radioactive sources of palladium-103, iodine-125, iridium-192 and ytterbium-169. Final report of a coordinated research project 2001-2005

    International Nuclear Information System (INIS)

    2006-06-01

    Radioisotopes have been used extensively for many years for several medical and industrial applications either in the form of an open source or encapsulated in an appropriate metallic container (sealed source). The design and technology for the preparation of radioactive sealed sources is an area of continuous development to satisfy an ever increasing demand for a larger variety of shapes, sizes, type of radioisotope and levels of radioactivity required for newer and specialized applications. In medicine, sealed sources using the radioisotopes of 125 I, 192 Ir and 103 Pd are commonly used for brachytherapy for the treatment of malignant diseases, and for bone density measurements. In industry, they are widely used for non-destructive testing (NDT), radiation processing, 'on-line' process control systems and on-line elemental analysis of mineral resources. Some well-known examples of such sources are 60 Co for industrial nucleonic gauges, 192 Ir sources for industrial radiography, 241 Am sources for smoke detectors and chemical analysers and, more recently, 169 Yb for NDT measurements of thin metallic tubes and plates. The current challenges in development include the production of miniature size sources with a high level of activity, a high degree of uniformity in the distribution of the radioactivity and the highest degree of safety, requiring stringent quality control methods. The IAEA has been promoting and supporting activities designed to increase the utilization of radiation and radioisotopes in several areas. In particular, in view of the proven benefits of, and an increasing demand for radioactive sealed sources for medical and industrial applications, upon the recommendation of several experts, a Coordinated Research Project (CRP) on Development of Radioactive Sources for Emerging Therapeutic and Industrial Applications was begun in 2002. The aim of the CRP was the optimization and testing of procedures and methods for the fabrication and quality control

  10. [125I]Iodopride

    International Nuclear Information System (INIS)

    Janowsky, A.; Ebert, M.H.; De Paulis, T.; Vanderbilt Univ., Nashville, TN; Kessler, R.M.; Vanderbilt Univ., Nashville, TN; Clanton, J.A.; Smith, H.E.

    1988-01-01

    Substituted benzamides are currently among the most selective antagonists at dopamine D-2 receptors, and high affinity ligands have been developed by substituting halogens into the aromatic ring of the benzamides. The authors report the high affinity, stereoselective, reversible, and sodium dependent binding of a new iodine-substituted benzamide, called [ 125 I]iodopride, to a membrane preparation from rat corpus striatum. 5 refs.; 1 figure

  11. Dosimetric Benefit of a New Ophthalmic Radiation Plaque

    Energy Technology Data Exchange (ETDEWEB)

    Marwaha, Gaurav, E-mail: marwahg2@ccf.org [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States); Wilkinson, Allan [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States); Bena, James [Department of Quantitative Health Sciences, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States); Macklis, Roger [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States); Singh, Arun D. [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Department of Ophthalmic Oncology, Cole Eye Institute, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States)

    2012-12-01

    Purpose: To determine whether the computed dosimetry of a new ophthalmic plaque, EP917, when compared with the standard Collaborative Ocular Melanoma Study (COMS) plaques, could reduce radiation exposure to vision critical structures of the eye. Methods and Materials: One hundred consecutive patients with uveal melanoma treated with COMS radiation plaques between 2007 and 2010 were included in this study. These treatment plans were generated with the use of Bebig Plaque Simulator treatment-planning software, both for COMS plaques and for EP917 plaques using I-125. Dose distributions were calculated for a prescription of 85 Gy to the tumor apex. Doses to the optic disc, opposite retina, lens, and macula were obtained, and differences between the 2 groups were analyzed by standard parametric methods. Results: When compared with the COMS plaques, the EP917 plaques used fewer radiation seeds by an average difference of 1.94 (P<.001; 95% confidence interval [CI], -2.8 to -1.06) and required less total strength of radiation sources by an average of 17.74 U (air kerma units) (P<.001; 95% CI, -20.16 to -15.32). The total radiation doses delivered to the optic disc, opposite retina, and macula were significantly less by 4.57 Gy, 0.50 Gy, and 11.18 Gy, respectively, with the EP917 plaques vs the COMS plaques. Conclusion: EP917 plaques deliver less overall radiation exposure to critical vision structures than COMS treatment plaques while still delivering the same total therapeutic dose to the tumor.

  12. Dosimetric Benefit of a New Ophthalmic Radiation Plaque

    International Nuclear Information System (INIS)

    Marwaha, Gaurav; Wilkinson, Allan; Bena, James; Macklis, Roger; Singh, Arun D.

    2012-01-01

    Purpose: To determine whether the computed dosimetry of a new ophthalmic plaque, EP917, when compared with the standard Collaborative Ocular Melanoma Study (COMS) plaques, could reduce radiation exposure to vision critical structures of the eye. Methods and Materials: One hundred consecutive patients with uveal melanoma treated with COMS radiation plaques between 2007 and 2010 were included in this study. These treatment plans were generated with the use of Bebig Plaque Simulator treatment-planning software, both for COMS plaques and for EP917 plaques using I-125. Dose distributions were calculated for a prescription of 85 Gy to the tumor apex. Doses to the optic disc, opposite retina, lens, and macula were obtained, and differences between the 2 groups were analyzed by standard parametric methods. Results: When compared with the COMS plaques, the EP917 plaques used fewer radiation seeds by an average difference of 1.94 (P<.001; 95% confidence interval [CI], −2.8 to −1.06) and required less total strength of radiation sources by an average of 17.74 U (air kerma units) (P<.001; 95% CI, −20.16 to −15.32). The total radiation doses delivered to the optic disc, opposite retina, and macula were significantly less by 4.57 Gy, 0.50 Gy, and 11.18 Gy, respectively, with the EP917 plaques vs the COMS plaques. Conclusion: EP917 plaques deliver less overall radiation exposure to critical vision structures than COMS treatment plaques while still delivering the same total therapeutic dose to the tumor.

  13. About the value of Ruthenium 106 brachytherapy in the treatment of uveal melanomas

    International Nuclear Information System (INIS)

    Langmann, G.; Mosboeck, G.; Stuecklschwaiger, G.; Muellner, K.; Lechner, H.; Faulborn, J.

    2002-01-01

    Background: to investigate the clinical course, sequelae and visual function of uveal melanomas treated with Ruthenium 106 brachytherapy. Patients and method: 47 patients who underwent Ruthenium 106 brachytherapy between 1985 and 2000 were evaluated using Kaplan Meier statistical method. Mean follow up interval was 22 month (range 8 - 152 months). Results: Local tumor control rate was 85 %, 5 years possibility to avoid enucleation was 75 %. The most important sequelae were radiation optic neuropathy (29 %), maculopathy (37 %) and radiation retinopathy (32 %). After terminating the study the 34 % of the patients achieved a visual acuity of 20/40 and more, another 34 % had a visual function of 20/200 and lower. Conclusion: Ruthenium 106 brachytherapy is our method of choice in small medium sized uveal melanomas and a maximum tumor prominence of 6 mm. Tumors have to be located in the midperiphery and outer periphery of the fundus including the ciliary body. In addition to the indications introduced by Lommatzsch we treated ciliary body melanomas with a tumor base more than 3 clock hours (by shifting the plaque) as an alternative therapy to enucleation. (author)

  14. Demonstration of brachytherapy boost dose-response relationships in glioblastoma multiforme

    International Nuclear Information System (INIS)

    Sneed, Penny K.; Lamborn, Kathleen R.; Larson, David A.; Prados, Michael D.; Malec, Mary K.; McDermott, Michael W.; Weaver, Keith A.; Phillips, Theodore L.; Wara, William M.; Gutin, Philip H.

    1996-01-01

    Purpose: To evaluate brachytherapy dose-response relationships in adults with glioblastoma undergoing temporary 125 I implant boost after external beam radiotherapy. Methods and Materials: Since June 1987, orthogonal radiographs using a fiducial marker box have been used to verify brain implant source positions and generate dose-volume histograms at the University of California, San Francisco. For adults who underwent brachytherapy boost for glioblastoma from June 1987 through December 1992, tumor volumes were reoutlined to ensure consistency and dose-volume histograms were recalculated. Univariate and multivariate analyses of various patient and treatment parameters were performed evaluating for influence of dose on freedom from local failure (FFLF) and actuarial survival. Results: Of 102 implant boosts, 5 were excluded because computer plans were unavailable. For the remaining 97 patients, analyses with adjustment for known prognostic factors (age, KPS, extent of initial surgical resection) and prognostic factors identified on univariate testing (adjuvant chemotherapy) showed that higher minimum brachytherapy tumor dose was strongly associated with improved FFLF (p = 0.001). A quadratic relationship was found between total biological effective dose and survival, with a trend toward optimal survival probability at 47 Gy minimum brachytherapy tumor dose (corresponding to about 65 Gy to 95% of the tumor volume); survival decreased with lower or higher doses. Two patients expired and one requires hospice care because of brain necrosis after brachytherapy doses > 63 Gy to 95% of the tumor volume with 60 Gy to > 18 cm 3 of normal brain. Conclusion: Although higher minimum brachytherapy tumor dose was strongly associated with better local control, a brachytherapy boost dose > 50-60 Gy may result in life-threatening necrosis. We recommend careful conformation of the prescription isodose line to the contrast enhancing tumor volume, delivery of a minimum brachytherapy

  15. Immunoreactivity of 125I-papain labelled by different methods

    International Nuclear Information System (INIS)

    Rauch, P.; Fukal, L.; Kas, J.; Tykva, R.

    1984-01-01

    Three different methods of papain iodination (with chloramine-T, lactoperoxidase and conjugation with Bolton-Hunter reagent) have been compared. The highest yield of 125 I-papain could be obtained using lactoperoxidase which enabled to achieve the highest immunoreactivity. 125 I-papain, labelled this way, is suitable for the radioimmunoassay of papain. (author)

  16. Dose rate effect of 125I irradiation on normal rabbit eyes and experimental choroidal melanoma

    International Nuclear Information System (INIS)

    Yang, C.M.; Olsen, K.R.; Schwade, J.G.; Houdek, P.V.; Markoe, A.M.; Pisciotta, V.; Xiaodong Wu

    1993-01-01

    The dose rate effect of radiation by 125 I plaque on choroidal melanoma and normal intraocular tissue was studied. In the first part of the experiment, high activity plaques (HAP) and low activity plagues (LAP) were implanted on rabbit eyes with experimental Greene choroidal melanoma to deliver a total dose of 10 000 cGy to the tumor apex. The mean dose rate calculated at 0.5 mm from the inner sclera in eight eyes with high activity plaques was 3341.5 cGy hr -1 while that in ten eyes with low activity plaques was 239.9 cGy hr -1 . For tumors less than 1.0 mm in height, both groups showed complete tumor regression at the tumor implantation site after plaque treatment. For tumours more than 1.0 mm in height, two out of two eyes in the low activity plaque group and one of four eyes in the high activity plaque group failed to show complete tumor regression. In the second part of the experiment, 125 I plaques were implanted on the sclera of 12 normal rabbits' eyes. Six received high dose rate plaque treatment, while the other six received low dose rate plaque treatment. Clinical and histologic examinations demonstrated more damaging effects to the normal chorioretinal tissues at the plaque implantation site in the high dose rate plaque group. These results suggest that high dose rate plaques are more effective than low dose rate plaques when tumor height is statistically controlled. (Author)

  17. Radioactive iodine absorbing properties of tetrathiafulvalene

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Tomiyasu; Nakamura, Asao (Ajinomoto Co. Inc., Kawasaki, Kanagawa (Japan). Central Research Labs.); Nogawa, Norio; Oohashi, Kunio; Morikawa, Naotake

    1989-05-01

    For the purpose of searching some effective absorbents of gaseous radioactive iodine, 16 substances considered as having an affinity for iodine were investigated with regular iodine and /sup 125/I. In a preliminary survey, only tetrathiafulvalene (TTF) was found to have satisfactory absorbing properties comparable to activated charcoal. A further detailed comparison of the properties between TTF and activated charcoal led us to the conclusion that the former has more preferable properties as absorbent of radioactive iodine than the latter in all points studied. The results are summarized as follows: (1) The absorption of iodine on TTF in atmosphere was about twice as much as that on activated charcoal. Desorption of iodine from saturatedly absorbed iodine on TTF was practically negligible except trace amount of initial desorption, while that on activated charcoal was considerable (3%/50h) even in the air at room temperature. (2) Absorbed amount of iodine on activated charcoal decreased with increasing gaseous iodine concentration, air flow rate, on humidity of flowing-air. On the other hand, those factors scarcely affected that on TTF. Under an air flow rate of 1m/s, activated charcoal absorbs only 80% of iodine, while TTF absorbs more than 99%. (3) In flowing-air saturated with water vapor, iodine absorbed on activated charcoal was gradually liberated although by small amount (0.08%/100h), while that on TTF was much more stable for a long period (0.004%/100h). As a conclusion, TTF is considered to be useful as a quite effective radioactive iodine absorbent, especially in the case where protection from radioactive iodine should be serious, though it is expensive now. (author).

  18. Radioactive iodine absorbing properties of tetrathiafulvalene

    International Nuclear Information System (INIS)

    Ito, Tomiyasu; Nakamura, Asao; Nogawa, Norio; Oohashi, Kunio; Morikawa, Naotake.

    1989-01-01

    For the purpose of searching some effective absorbents of gaseous radioactive iodine, 16 substances considered as having an affinity for iodine were investigated with regular iodine and 125 I. In a preliminary survey, only tetrathiafulvalene (TTF) was found to have satisfactory absorbing properties comparable to activated charcoal. A further detailed comparison of the properties between TTF and activated charcoal led us to the conclusion that the former has more preferable properties as absorbent of radioactive iodine than the latter in all points studied. The results are summarized as follows: (1) The absorption of iodine on TTF in atmosphere was about twice as much as that on activated charcoal. Desorption of iodine from saturatedly absorbed iodine on TTF was practically negligible except trace amount of initial desorption, while that on activated charcoal was considerable (3%/50h) even in the air at room temperature. (2) Absorbed amount of iodine on activated charcoal decreased with increasing gaseous iodine concentration, air flow rate, on humidity of flowing-air. On the other hand, those factors scarcely affected that on TTF. Under an air flow rate of 1m/s, activated charcoal absorbs only 80% of iodine, while TTF absorbs more than 99%. (3) In flowing-air saturated with water vapor, iodine absorbed on activated charcoal was gradually liberated although by small amount (0.08%/100h), while that on TTF was much more stable for a long period (0.004%/100h). As a conclusion, TTF is considered to be useful as a quite effective radioactive iodine absorbent, especially in the case where protection from radioactive iodine should be serious, though it is expensive now. (author)

  19. Oncological outcome, complications, lower urinary tract symptoms, and health-related quality of life after low-dose-rate salvage brachytherapy for recurrent prostate cancer following primary radiotherapy: a report of 8 cases

    Directory of Open Access Journals (Sweden)

    Makito Miyake

    2017-07-01

    Full Text Available Purpose: We evaluated our experience with low-dose-rate salvage brachytherapy for local recurrence after primary prostate radiotherapy, and described the changes in lower urinary tract symptoms and health-related quality of life. Material and methods: Between 2011 and 2016, eight men with local recurrence after primary prostate radiotherapy underwent iodine-125 salvage brachytherapy with a prescribed dose of 110 or 145 Gy. Recurrence-free survival was evaluated with a post-treatment prostate-specific antigen profile. The toxicity and changes in lower urinary tract symptoms and health-related quality of life during the follow-up were evaluated on the Common Terminology Criteria for Adverse Events version 4.0, International Prostate Symptom Score, Short Form-8, and Expanded Prostate Cancer Index Composite, respectively. Results: The median follow-up was 12.2 months (range, 8.3-71.9 after salvage brachytherapy. Of all eight patients, two (25% experienced treatment failure, one of whom developed left seminal vesicle recurrence 36 months after salvage brachytherapy for the right seminal vesicle recurrence, while the other developed bone metastases after 6 months. The International Prostate Symptom Scores peaked at 3 months, and returned to baseline by 6 months. The scores of all domains of health-related quality of life remained unchanged during the 12-month follow-up after salvage brachytherapy. Early grade ≤ 2 genitourinary toxicity was observed in five patients (63%, and late grade 2 gastrointestinal toxicity in one patient (13% having persistent diarrhea. No patient required intermittent catheterization and no grade 3 or greater toxicity occurred during follow-up. Conclusions: The present study is our experiment of eight patients undergoing salvage brachytherapy, suggesting that this modality is noninvasive, safe, and an effective salvage local treatment in selected patients. To our knowledge, this is the first study to evaluate lower urinary

  20. Comparison of Dosimetric and Biologic Effective Dose Parameters for Prostate and Urethra Using 131Cs and 125I for Prostate Permanent Implant Brachytherapy

    International Nuclear Information System (INIS)

    Sahgal, Arjun; Jabbari, Siavash; Chen, Josephine; Pickett, Barbie; Roach, Mack; Weinberg, Vivian; Hsu, I-C.; Pouliot, Jean

    2008-01-01

    Purpose: To compare the urethral and prostate absolute and biologic effective doses (BEDs) for 131 Cs and 125 I prostate permanent implant brachytherapy (PPI). Methods and Materials: Eight previously implanted manually planned 125 I PPI patients were replanned manually with 131 Cs, and re-planned using Inverse Planning Simulated Annealing. 131 Cs activity and the prescribed dose (115 Gy) were determined from that recommended by IsoRay. The BED was calculated for the prostate and urethra using an α/β ratio of 2 and was also calculated for the prostate using an α/β ratio of 6 and a urethral α/β ratio of 2. The primary endpoints of this study were the prostate D 90 BED (pD 90 BED) and urethral D 30 BED normalized to the maximal potential prostate D 90 BED (nuD 30 BED). Results: The manual plan comparison (α/β = 2) yielded no significant difference in the prostate D 90 BED (median, 192 Gy 2 for both isotopes). No significant difference was observed for the nuD 30 BED (median, 199 Gy 2 and 202 Gy 2 for 125 I and 131 Cs, respectively). For the inverse planning simulated annealing plan comparisons (α/β 2), the prostate D 90 BED was significantly lower with 131 Cs than with 125 I (median, 177 Gy 2 vs. 187 Gy 2 , respectively; p = 0.01). However, the nuD 30 BED was significantly greater with 131 Cs than with 125 I (median, 192 Gy 2 vs. 189 Gy 2 , respectively; p = 0.01). Both the manual and the inverse planning simulated annealing plans resulted in a significantly lower prostate D 90 BED (p = 0.01) and significantly greater nuD 30 BED for 131 Cs (p = 0.01), compared with 125 I, when the prostate α/β ratio was 6 and the urethral α/β ratio was 2. Conclusion: This report highlights the controversy in comparing the dose to both the prostate and the organs at risk with different radionuclides

  1. Labelling of S(-) BZM with Iodine-125 using Chloramine- T and Iodogen as Oxidizing Agents

    International Nuclear Information System (INIS)

    El-Ghany, E.A.; Farouk, N.; Raieh, M.; El-Kolaly, M.T.

    2000-01-01

    Labelling of (S)-N-[(1-ethyl-2-pyrrolidinyl) methyl]-2-hydroxy-3-iodo-6-methoxy benzamide [ S(-)-BZM] with iodine-125 using chloramine- T and iodogen as oxidizing agents was studied. The labelling yield was highly dependent on the ph of the reaction medium, S(-) BZM concentration, amounts of oxidizing agents and on the reaction time. High labelling yield greater than 90% was obtained by reacting 0.24 mu-M S(-)BZM solution with 0.24 μ M chloramine-T solution in phosphate buffer of ph 3 at room temperature for not more than 3 min. When iodogen was used as oxidizing agent, the labelling yield was found ≥ 80 % under the same conditions mentioned earlier. The advantages of the use of iodogen as oxidizing agent are : its molar ratio to substrate doses not has a great effect on the percent yield, no side products were produced as a result of the prolongation of the reaction time, and finally it is easy to be removed from the reaction mixture

  2. Synthesis of 125 I - Salicyl Hydroxamic Acid for Urinary Bladder Imaging

    International Nuclear Information System (INIS)

    Ibrahim, I.T.; Abou EL Zahab, M.; Hamed, M.

    2015-01-01

    Salicylhydroxamic acid is a salicylate derivative. Radiolabeling of Salicyl hydroxamic acid ( SHA ) with iodine-125 may have considerable interest for imaging of urinary bladder. This study is aimed to optimize the radiolabeling yield of Salicyl hydroxamic with radio iodine (125-123) using chloramine - T (CAT) as an oxidizing agent with respect to factors that affect the reaction conditions such as SHA amount, CAT amount, reaction time and ph of the reaction mixture. In - vitro stability of the radiolabeled complex was checked and it was found to be stable for up to 24 h. 125 I-SHA was injected via intravenous administration routes into normal male Sprague – Dawley rats. Bio - distribution studies have revealed that 125 I-SHA was excreted in urine with extent that it could give a clear image for urinary bladder especially if the bladder it tightly closed. The amount of 125 I - Salicyl hydroxamic excreted was increased in case of giving potassium bicarbonate to rat before injection of 125 I-SHA. The result of biodistribution study of 125 I - SHA in experimental animal suggest ed the possibility of using 123 I-SHA to image the urinary bladder

  3. Effect of iodination on human growth hormone and prolactin: characterized by bioassay, radioimmunoassay, radioreceptor assay, and electrophoresis

    International Nuclear Information System (INIS)

    Hughes, J.P.; Tanaka, T.; Gout, P.W.; Beer, C.T.; Noble, R.L.; Friesen, H.G.

    1982-01-01

    Human GH (hGH) and PRL (hPRL) were iodinated using lactoperoxidase. The iodinated hormones were characterized by RIA, radioreceptor assay (RRA), and bioassay (BA) using the Nb2 Node lymphoma cell line. The proportion of tracer that could bind to rat liver membranes or rabbit antibodies was determined, and the distribution of iodinated hormones was examined using polyacrylamide gel electrophoresis. Excess antibody was capable of precipitating 87.9% of the radioactivity associated with the hGH tracer and 86.0% of the hPRL tracer. The maximal specific binding to a liver membrane preparation averaged 67.3% of the [ 125 I]iodo-hGH radioactivity and 48.8% of the [ 125 I]iodo-hPRL radioactivity. The respective BA and RRA activity estimates for [ 125 ]iodo-hGH averaged 90% and 114% of the activity measured by the RIA. For [ 125 I]iodo-hPRL, the values were 75% by BA and 68% by RRA. The bioactivity profiles of iodinated hGH and hPRL shifted anodally on polyacrylamide gel electrophoresis in comparison to the bioactivity distribution of the respective uniodinated hormones. Iodine incorporation rather than oxidation appeared to be responsible for the shift. After electrophoresis, all eluates which contained significant radioactivity were active in the BA and RIA. Furthermore, specific activities calculated from the bioactive hormone and radioactivity in each electrophoretic segment agreed well with the average specific activity estimated from the amount of iodine incorporated into the protein peak upon gel filtration. These data suggest that hGH and hPRL to a major degree retain biological integrity after iodination

  4. Intravascular brachytherapy: a model for the calculation of the dose

    International Nuclear Information System (INIS)

    Pirchio, Rosana; Martin, Gabriela; Rivera, Elena; Cricco, Graciela; Cocca, Claudia; Gutierrez, Alicia; Nunez, Mariel; Bergoc, Rosa; Guzman, Luis; Belardi, Diego

    2002-01-01

    In this study we present the radiation dose distribution for a theoretical model with Montecarlo simulation, and based on an experimental model developed for the study of the prevention of restenosis post-angioplasty employing intravascular brachytherapy. In the experimental in vivo model, the atherosclerotic plaques were induced in femoral arteries of male New Zealand rabbits through surgical intervention and later administration of cholesterol enriched diet. For the intravascular irradiation we employed a 32P source contained within the balloon used for the angioplasty. The radiation dose distributions were calculated using the Monte Carlo code MCNP4B according to a segment of a simulated artery. We studied the radiation dose distribution in the axial and radial directions for different thickness of the atherosclerotic plaques. The results will be correlated with the biologic effects observed by means of histological analysis of the irradiated arteries (Au)

  5. SU-E-T-13: Comparison of Dose Rates with and without Gold Backing of USC #9 Radioactive Eye Plaque Using MCNP5.

    Science.gov (United States)

    Aryal, P; Molloy, J

    2012-06-01

    To show the effect of gold backing on dose rates for the USC #9 radioactive eye plaque. An I125 source (IsoAid model IAI-125A) and gold backing was modeled using MCNP5 Monte Carlo code. A single iodine seed was simulated with and without gold backing. Dose rates were calculated in two orthogonal planes. Dose calculation points were structured in two orthogonal planes that bisect the center of the source. A 2×2 cm matrix of spherical points of radius 0.2 mm was created in a water phantom of 10 cm radius. 0.2 billion particle histories were tracked. Dose differences with and without the gold backing were analyzed using Matlab. The gold backing produced a 3% increase in the dose rate near the source surface (<1mm) relative to that without the backing. This was presumably caused by fluorescent photons from the gold. At distances between 1 and 2 cm, the gold backing reduced the dose rate by up to 12%, which we attribute to a lack of scatter resulting from the attenuation from the gold. Dose differences were most pronounced in the radial direction near the source center but off axis. The dose decreased by 25%, 65% and 81% at 1, 2, and 3 mm off axis at a distance of 1 mm from the source surface. These effects were less pronounced in the perpendicular dimension near the source tip, where maximum dose decreases of 2% were noted. I 125 sources embedded directly into gold troughs display dose differences of 2 - 90%, relative to doses without the gold backing. This is relevant for certain types of plaques used in treatment of ocular melanoma. Large dose reductions can be observed and may have implications for scleral dose reduction. © 2012 American Association of Physicists in Medicine.

  6. Stereotactic interstitial brachytherapy for the treatment of oligodendroglial brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    El Majdoub, Faycal; Neudorfer, Clemens; Maarouf, Mohammad [University Hospital of Cologne, Department of Stereotaxy and Functional Neurosurgery, Cologne (Germany); University of Witten/Herdecke, Department of Stereotaxy and Functional Neurosurgery, Center of Neurosurgery, Cologne-Merheim Medical Center (CMMC), Cologne (Germany); Blau, Tobias; Deckert, Martina [University Hospital of Cologne, Department of Neuropathology, Cologne (Germany); Hellmich, Martin [University Hospital of Cologne, Institute of Statistics, Informatics and Epidemiology, Cologne (Germany); Buehrle, Christian [University Hospital of Cologne, Department of Stereotaxy and Functional Neurosurgery, Cologne (Germany); Sturm, Volker [University Hospital of Cologne, Department of Stereotaxy and Functional Neurosurgery, Cologne (Germany); University Hospital of Wurzburg, Department of Neurosurgery, Wuerzburg (Germany)

    2015-12-15

    We evaluated the treatment of oligodendroglial brain tumors with interstitial brachytherapy (IBT) using {sup 125}iodine seeds ({sup 125}I) and analyzed prognostic factors. Between January 1991 and December 2010, 63 patients (median age 43.3 years, range 20.8-63.4 years) suffering from oligodendroglial brain tumors were treated with {sup 125}I IBT either as primary, adjuvantly after incomplete resection, or as salvage therapy after tumor recurrence. Possible prognostic factors influencing disease progression and survival were retrospectively investigated. The actuarial 2-, 5-, and 10-year overall and progression-free survival rates after IBT for WHO II tumors were 96.9, 96.9, 89.8 % and 96.9, 93.8, 47.3 %; for WHO III tumors 90.3, 77, 54.9 % and 80.6, 58.4, 45.9 %, respectively. Magnetic resonance imaging demonstrated complete remission in 2 patients, partial remission in 13 patients, stable disease in 17 patients and tumor progression in 31 patients. Median time to progression for WHO II tumors was 87.6 months and for WHO III tumors 27.8 months. Neurological status improved in 10 patients and remained stable in 20 patients, while 9 patients deteriorated. There was no treatment-related mortality. Treatment-related morbidity was transient in 11 patients. WHO II, KPS ≥ 90 %, frontal location, and tumor surface dose > 50 Gy were associated with increased overall survival (p ≤ 0.05). Oligodendroglioma and frontal location were associated with a prolonged progression-free survival (p ≤ 0.05). Our study indicates that IBT achieves local control rates comparable to surgery and radio-/chemotherapy treatment, is minimally invasive, and safe. Due to the low rate of side effects, IBT may represent an attractive option as part of a multimodal treatment schedule, being supplementary to microsurgery or as a salvage therapy after chemotherapy and conventional irradiation. (orig.) [German] Die Behandlung oligodendroglialer Hirntumoren durch die interstitielle Brachytherapie

  7. Reduced dose to urethra and rectum with the use of variable needle spacing in prostate brachytherapy: a potential role for robotic technology.

    Science.gov (United States)

    Vyas, Shilpa; Le, Yi; Zhang, Zhe; Armour, Woody; Song, Daniel Y

    2015-08-01

    Several robotic delivery systems for prostate brachytherapy are under development or in pre-clinical testing. One of the features of robotic brachytherapy is the ability to vary spacing of needles at non-fixed intervals. This feature may play an important role in prostate brachytherapy, which is traditionally template-based with fixed needle spacing of 0.5 cm. We sought to quantify potential reductions in the dose to urethra and rectum by utilizing variable needle spacing, as compared to fixed needle spacing. Transrectal ultrasound images from 10 patients were used by 3 experienced planners to create 120 treatment plans. Each planner created 4 plan variations per patient with respect to needle positions: (125)I fixed spacing, (125)I variable spacing, (103)Pd fixed spacing, and (103)Pd variable spacing. The primary planning objective was to achieve a prostate V100 of 100% while minimizing dose to urethra and rectum. All plans met the objective of achieving prostate V100 of 100%. Combined results for all plans show statistically significant improvements in all assessed dosimetric variables for urethra (Umax, Umean, D30, D5) and rectum (Rmax, Rmean, RV100) when using variable spacing. The dose reductions for mean and maximum urethra dose using variable spacing had p values of 0.011 and 0.024 with (103)Pd, and 0.007 and 0.029 with (125)I plans. Similarly dose reductions for mean and maximum rectal dose using variable spacing had p values of 0.007 and 0.052 with (103)Pd, and 0.012 and 0.037 with (125)I plans. The variable needle spacing achievable by the use of robotics in prostate brachytherapy allows for reductions in both urethral and rectal planned doses while maintaining prostate dose coverage. Such dosimetric advantages have the potential in translating to significant clinical benefits with the use of robotic brachytherapy.

  8. Poster - 08: Preliminary Investigation into Collapsed-Cone based Dose Calculations for COMS Eye Plaques

    International Nuclear Information System (INIS)

    Morrison, Hali; Menon, Geetha; Sloboda, Ron

    2016-01-01

    Purpose: To investigate the accuracy of model-based dose calculations using a collapsed-cone algorithm for COMS eye plaques loaded with I-125 seeds. Methods: The Nucletron SelectSeed 130.002 I-125 seed and the 12 mm COMS eye plaque were incorporated into a research version of the Oncentra® Brachy v4.5 treatment planning system which uses the Advanced Collapsed-cone Engine (ACE) algorithm. Comparisons of TG-43 and high-accuracy ACE doses were performed for a single seed in a 30×30×30 cm 3 water box, as well as with one seed in the central slot of the 12 mm COMS eye plaque. The doses along the plaque central axis (CAX) were used to calculate the carrier correction factor, T(r), and were compared to tabulated and MCNP6 simulated doses for both the SelectSeed and IsoAid IAI-125A seeds. Results: The ACE calculated dose for the single seed in water was on average within 0.62 ± 2.2% of the TG-43 dose, with the largest differences occurring near the end-welds. The ratio of ACE to TG-43 calculated doses along the CAX (T(r)) of the 12 mm COMS plaque for the SelectSeed was on average within 3.0% of previously tabulated data, and within 2.9% of the MCNP6 simulated values. The IsoAid and SelectSeed T(r) values agreed within 0.3%. Conclusions: Initial comparisons show good agreement between ACE and MC doses for a single seed in a 12 mm COMS eye plaque; more complicated scenarios are being investigated to determine the accuracy of this calculation method.

  9. Poster - 08: Preliminary Investigation into Collapsed-Cone based Dose Calculations for COMS Eye Plaques

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Hali; Menon, Geetha; Sloboda, Ron [Cross Cancer Institute, Edmonton, AB, and University of Alberta, Edmonton, AB, Cross Cancer Institute, Edmonton, AB, and University of Alberta, Edmonton, AB, Cross Cancer Institute, Edmonton, AB, and University of Alberta, Edmonton, AB (Canada)

    2016-08-15

    Purpose: To investigate the accuracy of model-based dose calculations using a collapsed-cone algorithm for COMS eye plaques loaded with I-125 seeds. Methods: The Nucletron SelectSeed 130.002 I-125 seed and the 12 mm COMS eye plaque were incorporated into a research version of the Oncentra® Brachy v4.5 treatment planning system which uses the Advanced Collapsed-cone Engine (ACE) algorithm. Comparisons of TG-43 and high-accuracy ACE doses were performed for a single seed in a 30×30×30 cm{sup 3} water box, as well as with one seed in the central slot of the 12 mm COMS eye plaque. The doses along the plaque central axis (CAX) were used to calculate the carrier correction factor, T(r), and were compared to tabulated and MCNP6 simulated doses for both the SelectSeed and IsoAid IAI-125A seeds. Results: The ACE calculated dose for the single seed in water was on average within 0.62 ± 2.2% of the TG-43 dose, with the largest differences occurring near the end-welds. The ratio of ACE to TG-43 calculated doses along the CAX (T(r)) of the 12 mm COMS plaque for the SelectSeed was on average within 3.0% of previously tabulated data, and within 2.9% of the MCNP6 simulated values. The IsoAid and SelectSeed T(r) values agreed within 0.3%. Conclusions: Initial comparisons show good agreement between ACE and MC doses for a single seed in a 12 mm COMS eye plaque; more complicated scenarios are being investigated to determine the accuracy of this calculation method.

  10. Placement of empty catheters for an HDR-emulating LDR prostate brachytherapy technique: comparison to standard intraoperative planning.

    Science.gov (United States)

    Niedermayr, Thomas R; Nguyen, Paul L; Murciano-Goroff, Yonina R; Kovtun, Konstantin A; Neubauer Sugar, Emily; Cail, Daniel W; O'Farrell, Desmond A; Hansen, Jorgen L; Cormack, Robert A; Buzurovic, Ivan; Wolfsberger, Luciant T; O'Leary, Michael P; Steele, Graeme S; Devlin, Philip M; Orio, Peter F

    2014-01-01

    We sought to determine whether placing empty catheters within the prostate and then inverse planning iodine-125 seed locations within those catheters (High Dose Rate-Emulating Low Dose Rate Prostate Brachytherapy [HELP] technique) would improve concordance between planned and achieved dosimetry compared with a standard intraoperative technique. We examined 30 consecutive low dose rate prostate cases performed by standard intraoperative technique of planning followed by needle placement/seed deposition and compared them to 30 consecutive low dose rate prostate cases performed by the HELP technique. The primary endpoint was concordance between planned percentage of the clinical target volume that receives at least 100% of the prescribed dose/dose that covers 90% of the volume of the clinical target volume (V100/D90) and the actual V100/D90 achieved at Postoperative Day 1. The HELP technique had superior concordance between the planned target dosimetry and what was actually achieved at Day 1 and Day 30. Specifically, target D90 at Day 1 was on average 33.7 Gy less than planned for the standard intraoperative technique but was only 10.5 Gy less than planned for the HELP technique (p 0.05). Placing empty needles first and optimizing the plan to the known positions of the needles resulted in improved concordance between the planned and the achieved dosimetry to the target, possibly because of elimination of errors in needle placement. Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  11. Iodine-125 toxicity as a function of intranuclear radionuclide distribution

    International Nuclear Information System (INIS)

    Yasui, L.S.; Hofer, K.G.

    1984-01-01

    Chinese hamster ovary (CHO) cells were synchronized in the G/sub 1/ phase of the cell cycle by isoleucine deprivation and then subjected to 8 hr. labeling with /sup 125/I-iododeoxyuridine (/sup 125/IUdR) either in the presence or absence of aphidicolin. Cells labeled in the presence of aphidicolin showed a D/sub 0/ of 30 decays/cell as compared to a D/sub 0/ of 90-100 decays for control cells. Presumably, aphidicolin had shifted /sup 125/IUdR incorporation into a sensitive sub-fraction of the nuclear genome. However, no aphidicolin effect was seen in identical studies on asynchronous cell populations, i.e., both control and aphidicolin treated cells showed a D/sub 0/ of 90-100 decays/cell. An attempt was made to correlate /sup 125/I toxicity with intranuclear /sup 125/I distribution. Electron-microsopic autoradiography and Chi=squared analysis revealed that in all experimental groups grain density was highest in the heterochromatin region of the nucleus. However, isoleucine deprivation lead to a dramatic decrease in the nuclear area occupied by heterochromatin (19.5% in control cells, 0.7% in synchronized cells), resulting in a corresponding increase in area and grain density for the euchromatin containing portion of the nucleus. These observations suggest that any shift in intranuclear distribution of /sup 125/I causes a dramatic change in the toxic effects of intranuclear /sup 125/I decays

  12. Preparation of iodine - 125 - labeled insulin for radioimmunoassay: comparison of chloramine T and iodogen iodination

    International Nuclear Information System (INIS)

    Toledo e Souza, I.T. de; Giannella Neto, D.; Wajchenberg, B.L.

    1988-05-01

    Stoichiometric iodination of porcine insulin was performed to the general method of Hunter and Greenwood with modifications recommended by Roth. These method was compared with radioidination using Iodogen. Films of Iodogen react rapidly in the solid phase with aqueous mixtures of I - and proteins. For two methods satisfactory activity of the labeled porcine insulin was obtained and characteristics of the radioimmunoassay were studied. (author) [pt

  13. Prostate brachytherapy seed migration to the heart seen on cardiovascular computed tomographic angiography

    Directory of Open Access Journals (Sweden)

    Shilpa Sachdeva, MD

    2017-03-01

    Full Text Available Brachytherapy consists of placing radioactive sources into or adjacent to tumors, to deliver conformal radiation treatment. The technique is used for treatment of primary malignancies and for salvage in recurrent disease. Permanent prostate brachytherapy seeds are small metal implants containing radioactive sources of I-125, Pd-103, or Cs-131 encased in a titanium shell. They can embolize through the venous system to the lungs or heart and subsequently be detected by cardiovascular computed tomography. Cardiovascular imagers should be aware of the appearance of migrated seeds, as their presence in the chest is generally benign, so that unnecessary worry and testing are avoided. We report a case of a patient who underwent brachytherapy for prostate cancer and developed a therapeutic seeds embolus to the right ventricle.

  14. Labelling aflatoxine-B1 by radioactive iodine

    International Nuclear Information System (INIS)

    Kim, Y.S.; Park, K.B.; Sung, H.K.; Ryu, Y.W.

    1977-01-01

    Labelling aflatoxines, the potential carcinogenic compounds, by radioactive iodine has been studied. The auflatoxine-B 1 , which is known to be the most abundant components of auflatoxines in the nature, was labelled by radioactive iodine-125 through an acid catalyst chloroamine-T procedure. The radiochemical yield was amounted to 63.6%. The chemical structure of the labelled product was proved to be 6-iodo 5-methoxy coumarine structure of auflatoxine-B 1 molecule by means of I.R. and N.M.R. spectroscopy. The labelled product was orally administered in a test animal (rat) and examined the accumulation of radioactivity in the body at the definite time interval. The accumulation of the radioactivity was pronounced at the blood and the liver. There was no indication of the decomposition of auflatoxine-B 1 - 125 I in the organs of the test animal. (author)

  15. Behaviour of 125I added to limnocorrals in two Canadian Shield lakes of differing trophic states

    International Nuclear Information System (INIS)

    Bird, Glen A.; Motycka, M.; Rosentreter, J.; Schwartz, W.J.; Vilks, P.

    1995-01-01

    The main objectives of our investigation were to determine the loss rate of iodine from water to sediment and to gain a better understanding of the behaviour of iodine in Shield lakes. Iodine-125 and tritium ( 3 HHO) were added to the epilimnion of limnocorrals (enclosures) in mesotrophic Lake 226 and eutrophic Lake 227, Experimental Lakes Area, northwestern Ontario. The change in the 125 I/ 3 H ratio was used to measure the loss of 125 I from the epilimnion. Loss rate coefficients, (k), ranged from -0.0017 to -0.0074 day -1 . The 125 I was found primarily in the d ) had geometric means (/xgeometric standard deviations) of 2526/x62.1 l·kg -1 dry weight (dw) for suspended sediment, 1362 ± 2.9 l·kg -1 dw for particles in sediment traps and 132/x6 l·kg -1 dw for bottom sediment. Concentrations in fish ranged from = 8 to 184 Bq·g -1 dw, whereas concentration factors from water to fish ranged from 20 to 390 l·kg -1 dw. Iodine behaves as a conservative element in Shield lakes, although it is available for uptake by biota. The persistence of 125 I in water and its accumulation by fish emphasizes the potential importance of these pathways in the radiological dose to humans

  16. The effect of 17-AAG on iodine uptake kinetics of NIS-transfected anaplastic thyroid cancer

    International Nuclear Information System (INIS)

    Wang Renfei; Tan Jian; Li Wei; Meng Zhaowei; Zheng Wei

    2012-01-01

    Objective: To investigate the effect of 17-allylamino-17-demethoxy geldanamycin (17-AAG) on iodine uptake kinetics of NIS-transfected anaplastic thyroid cancer (ATC) cells. Methods: Lipofection was used to transfect the recombinant plasmid, namely pcDNA3.1-NIS, into FRO cells (ATC cell line). A stable cell line NIS-FRO was obtained by G418 resistance selection. 125 I was added into the medium, and influx and efflux experiments were performed. Different time-radioactivity curves were drawn, and further analysis was performed between the non-transfected cells (the control group) and NIS-FRO cells treated with 1 μmol/L 17-AAG for 24 h. Student's t-test was used to analyze the data. Results: The iodine uptake ability of the NIS-FRO cells was significantly higher than that of the FRO cells (about 10.68 times, t=45.329, P<0.001). However, 125 I out-flowed rapidly when removed from the medium, and the retention rate of 125 I in the NIS-FRO cells was only 10.5% of the initial amount after 30 rin. After treatment with 1 μmol/L 17-AAG for 24 h, the 125 I uptake ability of NIS-FRO cells further increased. During the 20-60 min incubation with 125 I, the iodine uptake ability of 17-AAG treated NIS-FRO cells increased significantly with radioactive counts of 31771.8- 54815.5 per minute,which was much higher than that of the control group (24020.3-41293.8 per minute; t=3.096, 4.275, 3.055, 4.292 and 5.496, respectively, all P<0.05). The iodine uptake ability increased about 24.8%-35.5%. Furthermore, 5-30 min after removing the medium, the retention rates of 125 I in the 17-AAG treated NIS-FRO cells were significantly increased compared with those of the control group (32.7%-85.2% vs 10.5%-56.8%; t=22.801, 13.096, 19.631, 38.205, 43.519, 29.322, respectively, all P<0.01), and 125 I efflux was reduced. After 30 min, 125 I retention rate of the treatment group was 32.7%, which was 3.1 times higher than that of the control group. Conclusion: The iodine uptake ability can be

  17. Radiological protection on interstitial brachytherapy and dose determination and exposure rate of an Ir-192 source through the MCNP-4B; Proteccion radiologica en braquiterapia intersticial y determinacion de la dosis y tasa de exposicion de una fuente de Ir-192 mediante el MCNP-4B

    Energy Technology Data Exchange (ETDEWEB)

    Morales L, M.E. [INEN, Av. Angamos Este 2520- Surquillo, Lima (Peru)

    2006-07-01

    The present work was carried out in the Neurological Sciences Institute having as objective to determine the dose and the rate of exhibition of the sources of Iridium 192, Iodine 125 and Palladium 103; which are used to carry out implant in the Interstitial Brachytherapy according to the TG43. For it we carry out a theoretical calculation, its are defined in the enter file: the geometry, materials of the problem and the radiation source, etc; in the MCNP-4B Monte Carlo code, considering a punctual source and for the dose determination we simulate thermoluminescent dosemeters (TLD): at 5 cm, 50 cm, 100 cm and 200 cm of the source. Our purpose is to analyze the radioprotection measures that should take into account in this Institute in which are carried out brain biopsies using a Micro mar stereotactic mark, and in a near future with the collaboration of a doctor and a cuban physique seeks to be carried out the Interstitial Brachytherapy technique with sources of Ir-192 for patient with tumors like glioblastoma, astrocytoma, etc. (Author)

  18. The influence of non-radiation factors on the kinetics of radioactive iodine metabolism in thyroid

    International Nuclear Information System (INIS)

    Kalistratova, V.S.; Filatov, V.V.; Shavrina, E.A.

    1985-01-01

    Estimation of the role non-radiation factors which may influence the dose formation in the most of all irradiated organs is considered very important for the normalization of radioactive isotopes of iodine. The significance of this problem was noted in some recent publications of NCARE. Since a human population which is being irradiated can be affected by the environmental temperature (43-45 deg and 4-6 deg C) and light (complete darkness and darkness for 21 hours) as well as vaccines (dysentery and typhoid) and alcohol (ethanol solutions of 0,02; 0,2; 2,0; and 20,0% concentration) were used as modifying factors. Iodine-125 administrated per os (0,8-1,3 MBq/rat) was used as a model for studying metabolism kinetics of radioactive iodine isotopes. Vaccination of animals results in a change of iodine-125 accumulation level in the thyroid depending on the time interval between an injection of the vaccine and administration of the radionuclide: one day after vaccination the levels of accumulation and the tissue doses formed by radionuclide in the thyroid were decreased by 1,5-2,0 times;14 days after vaccination they were increased by 1,5 times. Accumulation of iodine-125 in other endocrinal organs (pituitary and adrenal glands) was increased. The effect is independent of the type of injected vaccine. A single administration of 2,0-20,0% ethanol caused an increase of iodine-125 content in the thyroid. Chronical exposure to ethanol resulted in a decrease of iodine accumulation in the critical organ by 30% and the tissue doses accumulated by the thyroid, accordingly. Administration 0,02-0,2% ethanol did not affect metabolism kinetics of iodine-125. A single and chronical exposure to higher temperatures (43-45 deg C) decreased accumulation levels and absorbed doses of iodine-125 in the thyroid (by 30-50%) and delayed an elimination of the radionuclide from this organ. Lower temperatures of the environment (4-6 deg C), shorter light day and complete darkness did not affect

  19. Stability in time of iodinated tracers for Testosterone, Progesterone and cortisol radiommunoassays

    International Nuclear Information System (INIS)

    Nisembaum Alas, A.T.; Machado Curbelo, A.J.; Diaz Castro, D.; Chape Puertas, A.; Santander Lopez, A.M.; Cabrera Oliva, V.

    1996-01-01

    Stability in time of three iodihistamine derivates for steroid hormone radioimmunoassays (RIAs): Testosterone-3, Carboximetilxomine-histamine- 125I , Progesterone-11 Hemisuccinate-histamine- 125I and Cortisol-21 Hemisuccinate histamine- 125I produced in the National Institute of Endocrinology, Havana, Cuba was tested. Iodinated tracers were prepared according to Nars and Hunters's method, modifying in the purifying

  20. Radiation safety parameters following prostate brachytherapy

    International Nuclear Information System (INIS)

    Smathers, Sesalie; Wallner, Kent; Korssjoen, Tammy; Bergsagel, Carl; Hudson, Rick H.; Sutlief, Steven; Blasko, John

    1999-01-01

    Purpose: To determine the degree and variability of radiation exposure to the general public from patients after I-125 or Pd-103 prostate brachytherapy. Methods and Materials: Radiation exposure measurements were made from 38 consecutive, unselected patients with stage T1 or T2 prostatic carcinoma who had trans perineal I-125 or Pd-103 implants at the University of Washington in 1998. Results: The exposure rate at the anterior skin surface following a I-125 implant ranged from 2.2 to 8.9 mrem/hour (average: 5.0). The exposure rate at the anterior skin surface from a Pd-103 implant ranged from 0.5 to 4.9 mrem/hour (average: 1.7). Based on the current Nuclear Regulatory Commission (NRC) regulations the time required to reach the annual limit at the anterior skin surface would be 20 hours for I-125 and 59 hours for Pd-103. For exposure at the lateral skin surface, the times would exceed 500 hours for either isotope. Conclusions: This data suggest that patients need not be concerned about being a radiation risk to the general public following their procedure

  1. Assessment of carotid plaque vulnerability using structural and geometrical determinants

    International Nuclear Information System (INIS)

    Li, Z.Y.; Tang, T.; U-King-Im, J.; Graves, M.; Gillard, J.H.; Sutcliffe, M.

    2008-01-01

    Because many acute cerebral ischemic events are caused by rupture of vulnerable carotid atheroma and subsequent thrombosis, the present study used both idealized and patient-specific carotid atheromatous plaque models to evaluate the effect of structural determinants on stress distributions within plaque. Using a finite element method, structural analysis was performed using models derived from in vivo high-resolution magnetic resonance imaging (MRI) of carotid atheroma in 40 non-consecutive patients (20 symptomatic, 20 asymptomatic). Plaque components were modeled as hyper-elastic materials. The effects of varying fibrous cap thickness, lipid core size and lumen curvature on plaque stress distributions were examined. Lumen curvature and fibrous cap thickness were found to be major determinants of plaque stress. The size of the lipid core did not alter plaque stress significantly when the fibrous cap was relatively thick. The correlation between plaque stress and lumen curvature was significant for both symptomatic (p=0.01; correlation coefficient: 0.689) and asymptomatic patients (p=0.01; correlation coefficient: 0.862). Lumen curvature in plaques of symptomatic patients was significantly larger than those of asymptomatic patients (1.50±1.0 mm -1 vs 1.25±0.75 mm -1 ; p=0.01). Specific plaque morphology (large lumen curvature and thin fibrous cap) is closely related to plaque vulnerability. Structural analysis using high-resolution MRI of carotid atheroma may help in detecting vulnerable atheromatous plaque and aid the risk stratification of patients with carotid disease. (author)

  2. The need for international standardization in clinical beta dosimetry for brachytherapy

    International Nuclear Information System (INIS)

    Quast, U.; Boehm, J.; Kaulich, T.W.

    2002-01-01

    Beta radiation has found increasing interest in radiotherapy. Besides the curative treatment of small and medium-sized intraocular tumors by means of ophthalmic beta radiation plaques, intravascular brachytherapy has proven to successfully overcome the severe problem of restenosis after interventional treatment of arterial stenosis in coronaries and peripheral vessels in many clinical trials with a large number of patients. Prior to initiating procedures applying beta radiation in radiotherapy, however, there is a common need to specify methods for the determination and specification of the absorbed dose to water or tissue and their spatial distributions. The IAEA-TECDOC-1274 Calibration of photon and beta ray sources used in brachytherapy (2002) is a help for photon brachytherapy calibration. But, for beta seed and line sources, IAEA recommends well type ionization chambers as working standards which are far from measuring absorbed dose to water of the radiation clinically used. Although the application of such working standards seems to be more precise, large errors can occur when the medical physicist has to convert the calibration data to absorbed dose to water of the beta radiation emitted. The user must believe that the source is equally activated and that the manufacturer did not change the design and construction of the source encapsulation. With the DGMP Report 16 (2001) Guidelines for medical physical aspects of intravascular brachytherapy a very detailed code of practice is given, especially for the calibration and clinical dosimetry of intravascular beta radiation sources. As there is a global need for standardization in clinical dosimetry for intravascular brachytherapy utilizing beta radiation, the DIN-NAR, the German committee on standardization in radiology, task group dosimetry, has initiated an international adhoc working group for a new ISO work item proposal on the standardization of procedures in clinical dosimetry to guarantee reliable

  3. Auger-electron cascades, charge potential and microdosimetry of iodine-125

    Energy Technology Data Exchange (ETDEWEB)

    Booz, J.; Pomplun, E.; Olko, P.; Paretzke, H.G.

    1987-06-01

    This paper is a contribution to the microdosimetry of I-125. It shows microdosimetric spectra of individual and average disintegrations of I-125 for various target sizes and gives evidence for the relative contributions of energy-depositon events of low and high LET. It further presents information on the relative efficiencies of Auger-electrons and multiple charges in terms of local energy deposition, e.g. to model targets of DNA, and discusses their radiobiological implications, e.g. the microdosimetric understanding of the different efficiencies of specific and random incorporations of I-125. When I-125 is specifically incorporated into DNA, most of the energy deposition events are very large, e.g. above 40 keV/..mu..m for a simulated target volume of 20 nm diameter, regardless of the number and energy of Auger electrons emitted. Therefore it is not necessary, for the discussion of the radiobiological implications, to distinguish between different classes of disintegrations. For unspecific, homogeneous incorporation of I-125 somewhere into tissue, about 20% of the dose to critical targets of 25 nm diameter is made up by disintegrations that happen to occur within these targets. When assuming that other critical targets and target structures can be neglected, this part of the dose will be equally effective as in the case of specific incorporation of I-125 into such target models. In addition, there are the normal, low-LET radiation effects from the other, 80% large fraction of the dose. With this information, for the biological systems and end points for which a short section of the elemental chromatine fiber can be taken as the relevant critical target, it is shown that the expected D/sub 37/ value for homogeneous unspecific incorporation of I-125 can be estimated when the D/sub 37/ for specific incorporation in DNA is known.

  4. An assessment of the vulnerability of carotid plaques: a comparative study between intraplaque neovascularization and plaque echogenicity

    International Nuclear Information System (INIS)

    Zhou, Yangyang; Li, Yan; Bai, Yang; Chen, Ying; Sun, Xiaofeng; Zhu, Yingqiao; Wu, Jiang

    2013-01-01

    Carotid plaque echolucency as detected by Color Doppler ultrasonography (CDUS) has been used as a potential marker of plaque vulnerability. However, contrast-enhanced ultrasound (CEUS) has recently been shown to be a valuable method to evaluate the vulnerability and neovascularization within carotid atherosclerotic plaques. The aim of this study was to compare CEUS and CDUS in the assessment of plaque vulnerability using transcranial color Doppler (TCD) monitoring of microembolic signals (MES) as a reference technique. A total of 46 subjects with arterial stenosis (≥ 50%) underwent a carotid duplex ultrasound, TCD monitoring of MES and CEUS (SonoVue doses of 2.0 mL) within a span of 3 days. The agreement between the CEUS, CDUS, and MES findings was assessed with a chi-square test. A p-value less than 0.05 was considered statistically significant. Neovascularization was observed in 30 lesions (44.4%). The vascular risk factors for stroke were similar and there were no age or gender differences between the 2 groups. Using CEUS, MES were identified in 2 patients (12.5%) within class 1 (non-neovascularization) as opposed to 15 patients (50.0%) within class 2 (neovascularization) (p = 0.023). CDUS revealed no significant differences in the appearance of the MES between the 2 groups (hyperechoic and hypoechoic) (p = 0.237). This study provides preliminary evidence to suggest that intraplaque neovascularization detected by CEUS is associated with the presence of MESs, where as plaque echogenicity on traditional CDUS does not. These findings argue that CEUS may better identify high-risk plaques

  5. Synthesis, Kinetic Study, and Biological Distribution of Iodine-125-N-[3-(4 morpholino) propyl] -N-methyl-2-hydroxy-5-iodo-3-methylbenzylamine (ERC-9): A Possible Melanoma Therapeutic Agent

    International Nuclear Information System (INIS)

    EL-Ghany, E.A.

    2008-01-01

    This study describe the labeling of N-[3-(4-morpholino) propyl] -N-methyl-2 hydroxy-5-iodo-3-methylbenzylamine (ERC-9) with iodine-125 in liquid and ill melt states .The labeling in liquid state was controlled by many factors such as the ratio of radioiodine to the molar concentration of ERC-9, This test was carried out using iodine-131 instead of iodine-125 due to high activity required, and the maximum yield of 131 I ERC-9 was obtained at 90 - 277 MBq NaI 131 to 19.9 m M of ERC-9. The labeling reaction was preceded well at ph 3,5. Acetic acid was the most suitable solvent for the labeling reaction. One mg of cuprous chloride was catalyzed the reaction and reduced the reaction time from 45 min to 20 min. The molarity of sodium hydroxide played an important role in the labeling reaction, as the labeling yield was maximum at 0,01 M NaOH. The labeling in melt state using ammonium acetate as catalyst produced 92 % radiochemical yield. The labeling in melt state was fast, easy, and done in one-step. The biological studies reflected that the tracer was lipophilic, as high liver uptake (39.4 ± 2,1 %) was observed at 1 h post injection. The tracer was excreted to some extent via the kidneys. Activation energy required for the reaction completion in the presence of cuprous chloride was 31.4 KJ/ mol when the reaction was preceded at 80 degree C for 80 min

  6. Preoperative irradiation, lymphadenectomy, and 125iodine implantation for patients with localized carcinoma of the prostate

    International Nuclear Information System (INIS)

    DeLaney, T.F.; Shipley, W.U.; O'Leary, M.P.; Biggs, P.J.; Prout, G.R. Jr.

    1986-01-01

    Fifty-four patients with clinically and surgically localized prostatic carcinoma were treated with low-dose preoperative irradiation (1050 cGy), pelvic lymphadenectomy, and interstitial 125 Iodine implantation. The follow-up range is 2 to 9 years with a median follow-up of 5 years. Overall local tumor control is 92%. Actuarial 5-year survival is 86% and the actuarial disease-free survival at 5 years is 73%. Patients with poorly differentiated tumors have a significantly worse actuarial survival (62%) at 5 years than patients with well (95%) or moderately well differentiated tumors (93%), p = 0.04. Disease-free survival at 5 years was influenced by grade: well (100%), moderate (60%), and poor (48%), p = 0.03. Multivariate regression analysis indicates that only the degree of differentiation (p = 0.05) significantly impacts on survival. Both degree of differentiation (p = 0.04) and nodal status (p = 0.03) significantly influence disease-free survival. Potency has been maintained in 71% of patients potent at the time of implantation. Late reactions have been acceptable to date: bladder outlet obstruction (13%), mild proctitis (13%), cystourethritis (6%), incontinence (2%), and prostatic calculi (2%)

  7. Treatment of hepatocellular carcinoma adjacent to large blood vessels using 1.5T MRI-guided percutaneous radiofrequency ablation combined with iodine-125 radioactive seed implantation

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Zheng-Yu, E-mail: linsinlan@yahoo.com.cn [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); Chen, Jin, E-mail: snow8968851@163.com [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); Deng, Xiu-Fen, E-mail: dxf197286@yahoo.com.cn [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China)

    2012-11-15

    Objective: The objective is to study the technology associated with and feasibility of the treatment of hepatocellular carcinoma (HCC) adjacent to large blood vessels using 1.5T MRI-guided radiofrequency ablation combined with iodine-125 (I-125) radioactive seed implantation. Methods: Sixteen patients with a total of 24 HCC lesions (average maximum diameter: 2.35 {+-} 1.03 cm) were pathologically confirmed by biopsy or clinically diagnosed received 1.5T MRI-guided percutaneous radiofrequency ablation (RFA) treatment. Each patient had one lesion adjacent to large blood vessels ({>=}3 mm); after the ablation, I-125 radioactive seeds were implanted in the portions of the lesions that were adjacent to the blood vessels. Results: All the ablations and I-125 radioactive seed implantations were successful; a total of 118 seeds were implanted. The ablated lesions exhibited hypointense signals on the T2WI sequence with a thin rim of hyperintense signals; they also exhibited significant hyperintense signals on the T1WI sequence with clear boundaries. The average follow-up period was 11.1 {+-} 6.2 months. There were 23 complete responses and one partial response in the 24 lesions. The alpha-fetoprotein (AFP) levels of the patients significantly decreased. Conclusion: The 1.5T MRI-guided RFA combined with I-125 radioactive seed implantation for the treatment of HCC adjacent to large blood vessels is an effective technology.

  8. Prospective evaluation of quality of life after permanent prostate brachytherapy with I-125: Importance of baseline symptoms and of prostate-V150

    International Nuclear Information System (INIS)

    Vordermark, Dirk; Noe, Michael; Markert, Klaus; Wulf, Joern; Mueller, Gerd; Bratengeier, Klaus; Beckmann, Gabriele; Baier, Fabian; Guckenberger, Matthias; Schiefelbein, Frank; Schoen, Georg; Flentje, Michael; Baier, Kurt

    2009-01-01

    Background and purpose: Detailed knowledge of quality of life (QoL) after permanent I-125 brachytherapy may aid in counselling patients with early-stage prostate cancer. Materials and methods: Seventy-four consecutive patients with low-risk prostate cancer were asked to complete the EORTC QLQ-C30 questionnaire with the prostate-specific PR25 module before implant, four weeks and one year after implant (response rates 97%, 88% and 89%, respectively). Implant characteristics were correlated with QoL scores. Results: Global QoL was stable from pre-treatment to one year after implant and similar to age-adjusted scores of healthy controls. Significant changes versus baseline in QLQ-C30 domains were worsened social function at four weeks, increased constipation at four weeks and at one year and improved emotional function at one year. PR25 urinary symptoms were significantly increased at four weeks and, despite some improvement, at one year; bowel symptoms were slightly increased. Both types of symptoms were most strongly related with pre-treatment symptom scores. Prostate-V150 was the only implant parameter significantly associated with both urinary and bowel symptoms at four weeks and one year. Conclusions: Limiting the high-dose subvolume in the prostate may be beneficial to reduce urinary and bowel symptoms but the major determinant of symptoms after I-125 implant is the baseline symptom level.

  9. Evaluation of hypothetical (153)Gd source for use in brachytherapy.

    Science.gov (United States)

    Ghorbani, Mahdi; Behmadi, Marziyeh

    2016-01-01

    The purpose of this work is to evaluate the dosimetric parameters of a hypothetical (153)Gd source for use in brachytherapy and comparison of the dosimetric parameters with those of (192)Ir and (125)I sources. Dose rate constant, the radial dose function and the two dimensional (2D) anisotropy function data for the hypothetical (153)Gd source were obtained by simulation of the source using MCNPX code and then were compared with the corresponding data reported by Enger et al. A comprehensive comparison between this hypothetical source and a (192)Ir source with similar geometry and a (125)I source was performed as well. Excellent agreement was shown between the results of the two studies. Dose rate constant values for the hypothetical (153)Gd, (192)Ir, (125)I sources are 1.173 cGyh(-1) U(-1), 1.044 cGyh(-1) U(-1), 0.925 cGyh(-1) U(-1), respectively. Radial dose function for the hypothetical (153)Gd source has an increasing trend, while (192)Ir has more uniform and (125)I has more rapidly falling off radial dose functions. 2D anisotropy functions for these three sources indicate that, except at 0.5 cm distance, (192)Ir and (125)I have more isotropic trends as compared to the (153)Gd source. A more uniform radial dose function, and 2D anisotropy functions with more isotropy, a much higher specific activity are advantages of (192)Ir source over (153)Gd. However, a longer half-life of (153)Gd source compared to the other two sources, and lower energy of the source with respect to (192)Ir are advantages of using (153)Gd in brachytherapy versus (192)Ir source.

  10. Iodine-125 labeling of 4, 4'-diaminodiphenyl sulfone, dapsone (DDS): an imaging probe for inflammation

    International Nuclear Information System (INIS)

    EL-Ghany, E.A.; EI-Wetery, A.S.; Hussin, H.; Saleh, Z.A.; EI-SheiKH, R.

    2007-01-01

    Dapsone is a drug that, alone or in combination with other therapeutic agents, is effective in a variety of infectious diseases, including leprosy and malaria. The labeling of this antibacterial agent with iodine-125 offers an advantage to image and identify leprosy. The labeling reaction was carded out in an acidic medium with ph 2. Both chloramine- T and iodogen coated glass frits produced a high yield of 125 IDDS tracer more than 96 %, when the reaction mixture was heated at 100 degree C for 15 min at ph 2. The biodistribution studies gave the possibility to.use this tracer as a probe for the detection of septic and aseptic inflammations. The intra-venous injection of the tracer into the mice reflects the lipophilic nature of the tracer, as the liver uptake at early time post injection (1/2 h) was 14.4 %. The tracer was excreted via the liver and to some extent via the kidneys. The in-vivo stability of the tracer was confirmed as the activity taken by the thyroid gland not exceed 2.3 % at 2 h postinjection. The tracer tends to be retained in the muscle as the activity taken by the muscle was 5 % at 2 h post injection. The interesting observation during this study was the uptake of the tracer by the brain, which confirm the ability of the tracer to pass through the blood brain barrier (BUB) with activity more than 3 % and still fixed even at one hour post injection. This brain uptake support the idea to , use this tracer as brain imaging agent, especially the tracer was retained in the brain tissues for long time. The ratio of the uptake of E.Coli- and oil-inflammed muscles to that of the non-inflammed muscle were high and equal to 1.8,2.5, and 3.7 and 1.5, 2.75, and 3.3 at 1/2, 2, and 4 hours post injection, respectively. Due to the inability to cultivate mycobacterium leprae in artificial media and the lack of experimental animals susceptible to human leprosy, a biological evaluation of 125 IDDS tracer in leprotie animals can not be done

  11. Dosimetric verification of a dedicated 3D treatment planning system for episcleral plaque therapy

    International Nuclear Information System (INIS)

    Knutsen, Stig; Hafslund, Rune; Monge, Odd R.; Valen, Harald; Muren, Ludvig Paul; Rekstad, Bernt Louni; Krohn, Joergen; Dahl, Olav

    2001-01-01

    Purpose: Episcleral plaque therapy (EPT) is applied in the management of some malignant ocular tumors. A customized configuration of typically 4 to 20 radioactive seeds is fixed in a gold plaque, and the plaque is sutured to the scleral surface corresponding to the basis of the intraocular tumor, allowing for a localized radiation dose delivery to the tumor. Minimum target doses as high as 100 Gy are directed at malignant tumor sites close to critical normal tissues (e.g., optic disc and macula). Precise dosimetry is therefore fundamental for judging both the risk for normal tissue toxicity and tumor dose prescription. This paper describes the dosimetric verification of a commercially available dedicated treatment planning system (TPS) for EPT when realistic multiple-seed configurations are applied. Materials and Methods: The TPS Bebig Plaque Simulator is used to plan EPT at our institution. Relative dose distributions in a water phantom, including central axis depth dose and off-axis dose profiles for three different plaques, the University of Southern California (USC) No. 9 and the Collaborative Ocular Melanoma Study (COMS) 12-mm and 20-mm plaques, were measured with a diode detector. Each plaque was arranged with realistic multiple 125 I seed configurations. The measured dose distributions were compared to the corresponding dose profiles calculated with the TPS. All measurements were corrected for the angular sensitivity variation of the diode. Results: Single-seed dose distributions measured with our dosimetry setup agreed with previously published data within 3%. For the three multiple-seed plaque configurations, the measured and calculated dose distributions were in good agreement. For the central axis depth doses, the agreement was within 4%, whereas deviations up to 11% were observed in single points far off-axis. Conclusions: The Bebig Plaque Simulator is a reliable TPS for calculating relative dose distributions around realistic multiple 125 I seed

  12. Fast dose kernel interpolation using Fourier transform with application to permanent prostate brachytherapy dosimetry.

    Science.gov (United States)

    Liu, Derek; Sloboda, Ron S

    2014-05-01

    Boyer and Mok proposed a fast calculation method employing the Fourier transform (FT), for which calculation time is independent of the number of seeds but seed placement is restricted to calculation grid points. Here an interpolation method is described enabling unrestricted seed placement while preserving the computational efficiency of the original method. The Iodine-125 seed dose kernel was sampled and selected values were modified to optimize interpolation accuracy for clinically relevant doses. For each seed, the kernel was shifted to the nearest grid point via convolution with a unit impulse, implemented in the Fourier domain. The remaining fractional shift was performed using a piecewise third-order Lagrange filter. Implementation of the interpolation method greatly improved FT-based dose calculation accuracy. The dose distribution was accurate to within 2% beyond 3 mm from each seed. Isodose contours were indistinguishable from explicit TG-43 calculation. Dose-volume metric errors were negligible. Computation time for the FT interpolation method was essentially the same as Boyer's method. A FT interpolation method for permanent prostate brachytherapy TG-43 dose calculation was developed which expands upon Boyer's original method and enables unrestricted seed placement. The proposed method substantially improves the clinically relevant dose accuracy with negligible additional computation cost, preserving the efficiency of the original method.

  13. Use of [125I]-iodohistamine-labelled steroid derivatives as radioligands for radioimmunoassay of natural and synthetic steroids

    International Nuclear Information System (INIS)

    Stanczyk, F.Z.; Goebelsmann, U.

    1981-01-01

    [ 125 I]-Iodohistamine-labelled steroid derivatives were prepared and utilized as radioligands in radioimmunoassays of progesterone, testosterone, estradiol, estriol, estriol-16α-glucuronide, levonorgestrel, norethindrone and medroxyprogesterone acetate. The binding of these iodinated radioligands was compared to that of the corresponding tritiated steroids and their effect on the sensitivity and slope of standard curves was examined. The results demonstrate that much higher antibody dilutions could be used with iodinated than with tritiated radioligands. In general, standard curves obtained with iodinated radioligands were more sensitive than those obtained with tritiated steroids, but standard curves had steeper slopes when tritiated rather than iodinated radioligands were used. The data, summarizing our 5-year experience with steroid-[ 125 I]-iodohistamine derivatives, indicate that these tracers play an important role in radioimmunoassay systems for both natural and synthetic steroids. (author)

  14. Cobalt60 plaques in recurrent retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Fass, D.; McCormick, B.; Abramson, D.; Ellsworth, R. (Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, NY, NY (USA))

    1991-08-01

    Cobalt60 plaque irradiation is one treatment option for patients with recurrent retinoblastoma following conventional external beam irradiation (ERT). Tumorocidal doses can be delivered without excessive risk of normal tissue injury. In patients not considered candidates for xenon arc or cryotherapy, 60Co is an alternative to enucleation. Between 1968 and 1987, 85 patients were treated with 60Co plaques, 72 of whom had failed prior ERT. Age at diagnosis ranged from 1 week to 4 years. There are 37 males and 35 females. Seventy-one patients had bilateral disease and one had unilateral. Three patients had both eyes plaqued. Prior ERT ranged from 30 to 70 Gy (mean 4200 Gy). Time from initial therapy to failure ranged from 13 to 60 months. Cobalt plaques of 10 mm, 15 mm, or 10 {times} 15 mm were used depending on tumor size and location. Dose prescribed to the apex of the tumor ranged from 30 to 50 Gy (median 40 Gy) given over 3 to 8 days. Twelve patients had two plaque applications; three patients had three plaque applications. All patients were followed with routine ophthalmoscopic examinations. Follow-up ranged from 2 to 22 years (mean 8.7). Seven patients died of metastatic disease; 10 patients developed non-ocular second tumors. Thirty patients required enucleation. Twenty-two patients had clear tumor progression, two patients had radiation complications, and six patients had a combination of tumor growth and complications. Cobalt60 can salvage eyes in retinoblastoma patients failing ERT. Currently, the authors are using I125 in an attempt to spare normal ocular tissue and reduce subsequent complications.

  15. Cobalt60 plaques in recurrent retinoblastoma

    International Nuclear Information System (INIS)

    Fass, D.; McCormick, B.; Abramson, D.; Ellsworth, R.

    1991-01-01

    Cobalt60 plaque irradiation is one treatment option for patients with recurrent retinoblastoma following conventional external beam irradiation (ERT). Tumorocidal doses can be delivered without excessive risk of normal tissue injury. In patients not considered candidates for xenon arc or cryotherapy, 60Co is an alternative to enucleation. Between 1968 and 1987, 85 patients were treated with 60Co plaques, 72 of whom had failed prior ERT. Age at diagnosis ranged from 1 week to 4 years. There are 37 males and 35 females. Seventy-one patients had bilateral disease and one had unilateral. Three patients had both eyes plaqued. Prior ERT ranged from 30 to 70 Gy (mean 4200 Gy). Time from initial therapy to failure ranged from 13 to 60 months. Cobalt plaques of 10 mm, 15 mm, or 10 x 15 mm were used depending on tumor size and location. Dose prescribed to the apex of the tumor ranged from 30 to 50 Gy (median 40 Gy) given over 3 to 8 days. Twelve patients had two plaque applications; three patients had three plaque applications. All patients were followed with routine ophthalmoscopic examinations. Follow-up ranged from 2 to 22 years (mean 8.7). Seven patients died of metastatic disease; 10 patients developed non-ocular second tumors. Thirty patients required enucleation. Twenty-two patients had clear tumor progression, two patients had radiation complications, and six patients had a combination of tumor growth and complications. Cobalt60 can salvage eyes in retinoblastoma patients failing ERT. Currently, the authors are using I125 in an attempt to spare normal ocular tissue and reduce subsequent complications

  16. Reduced dose to urethra and rectum with the use of variable needle spacing in prostate brachytherapy: a potential role for robotic technology

    Science.gov (United States)

    Vyas, Shilpa; Le, Yi; Zhang, Zhe; Armour, Woody

    2015-01-01

    Purpose Several robotic delivery systems for prostate brachytherapy are under development or in pre-clinical testing. One of the features of robotic brachytherapy is the ability to vary spacing of needles at non-fixed intervals. This feature may play an important role in prostate brachytherapy, which is traditionally template-based with fixed needle spacing of 0.5 cm. We sought to quantify potential reductions in the dose to urethra and rectum by utilizing variable needle spacing, as compared to fixed needle spacing. Material and methods Transrectal ultrasound images from 10 patients were used by 3 experienced planners to create 120 treatment plans. Each planner created 4 plan variations per patient with respect to needle positions: 125I fixed spacing, 125I variable spacing, 103Pd fixed spacing, and 103Pd variable spacing. The primary planning objective was to achieve a prostate V100 of 100% while minimizing dose to urethra and rectum. Results All plans met the objective of achieving prostate V100 of 100%. Combined results for all plans show statistically significant improvements in all assessed dosimetric variables for urethra (Umax, Umean, D30, D5) and rectum (Rmax, Rmean, RV100) when using variable spacing. The dose reductions for mean and maximum urethra dose using variable spacing had p values of 0.011 and 0.024 with 103Pd, and 0.007 and 0.029 with 125I plans. Similarly dose reductions for mean and maximum rectal dose using variable spacing had p values of 0.007 and 0.052 with 103Pd, and 0.012 and 0.037 with 125I plans. Conclusions The variable needle spacing achievable by the use of robotics in prostate brachytherapy allows for reductions in both urethral and rectal planned doses while maintaining prostate dose coverage. Such dosimetric advantages have the potential in translating to significant clinical benefits with the use of robotic brachytherapy. PMID:26622227

  17. Evaluation of new iodinated acridine derivatives for targeted radionuclide therapy of melanoma using {sup 125}I, an Auger electron emitter

    Energy Technology Data Exchange (ETDEWEB)

    Gardette, M.; Papon, J.; Bonnet, M.; Labarre, P.; Miot-Noirault, E.; Madelmont, J. C.; Chezal, J. M.; Moins, N. [UMR 990, INSERM, Universite d' Auvergne, Clermont-Ferrand (France); Desbois, N. [EA 3660, Universite de Bourgogne, Dijon (France); Wu, T. D.; Guerquin-Kern, J. L. [U 759 INSERM, Institute Curie, Orsay (France)

    2013-06-01

    The full text of the publication follows. The increasing incidence of melanoma and the lack of effective therapy on the disseminated form have led to an urgent need for new specific therapies. Several iodo-benzamides or analogs are known to possess specific affinity for melanoma tissue. New hetero-aromatic derivatives have been designed with a cytotoxic moiety and termed DNA intercalating agents. These compounds could be applied in targeted radionuclide therapy using {sup 125}I, Auger electrons emitter which gives high-energetic localized irradiation. Two iodinated acridine derivatives have been reported to present an in vivo kinetic profile conducive to application in targeted radionuclide therapy. The aim of the present study was to perform a preclinical evaluation of these compounds. The DNA intercalating property was confirmed for both compounds. After radiolabeling with {sup 125}I, the two compounds induced in vitro a significant radiotoxicity on B16F0 melanoma cells. The acridine compound, ICF01040, appeared more radio toxic than the acridone compound, ICF01035. While cellular uptake was similar for both compounds, SIMS analysis and in vitro protocol showed a stronger affinity for melanin with ICF01035, which was able to induce a predominant scavenging process in the melanosome and restrict access to the nucleus. Nevertheless, an important radiotoxicity was measured for the two compounds while the nuclear accumulation was low. Indeed, even if nuclear localization remains the main target sensitive to Auger electrons, the cell membrane remains sensitive to {sup 125}I decays. So, these compounds may induce secondary toxic effects of irradiation, such as membrane lipid damage. Conducted to current experiments are evaluate such hypothesis. Taken together, these results suggest that ICF01040 is a better candidate for application in targeted radionuclide therapy using {sup 125}I. The next step will be in vivo evaluation, where high tumoral vectorization gives

  18. Dose rate constant and energy spectrum of interstitial brachytherapy sources

    International Nuclear Information System (INIS)

    Chen Zhe; Nath, Ravinder

    2001-01-01

    In the past two years, several new manufacturers have begun to market low-energy interstitial brachytherapy seeds containing 125 I and 103 Pd. Parallel to this development, the National Institute of Standards and Technology (NIST) has implemented a modification to the air-kerma strength (S K ) standard for 125 I seeds and has also established an S K standard for 103 Pd seeds. These events have generated a considerable number of investigations on the determination of the dose rate constants (Λ) of interstitial brachytherapy seeds. The aim of this work is to study the general properties underlying the determination of Λ and to develop a simple method for a quick and accurate estimation of Λ. As the dose rate constant of clinical seeds is defined at a fixed reference point, we postulated that Λ may be calculated by treating the seed as an effective point source when the seed's source strength is specified in S K and its source characteristics are specified by the photon energy spectrum measured in air at the reference point. Using a semi-analytic approach, an analytic expression for Λ was derived for point sources with known photon energy spectra. This approach enabled a systematic study of Λ as a function of energy. Using the measured energy spectra, the calculated Λ for 125 I model 6711 and 6702 seeds and for 192 Ir seed agreed with the AAPM recommended values within ±1%. For the 103 Pd model 200 seed, the agreement was 5% with a recently measured value (within the ±7% experimental uncertainty) and was within 1% with the Monte Carlo simulations. The analytic expression for Λ proposed here can be evaluated using a programmable calculator or a simple spreadsheet and it provides an efficient method for checking the measured dose rate constant for any interstitial brachytherapy seed once the energy spectrum of the seed is known

  19. 125I-labeling and purification of peptide hormones and bovine serum albumin

    International Nuclear Information System (INIS)

    Nemeth, J; Jakab, B.; Szilvassy, Z.; Oroszi, G.; Roeth, E.; Magyarlaki, M.; Farkas, B.

    2002-01-01

    The iodination and separation of various diagnostically and/or experimentally important peptides including (Tyr 1 )-somatostatin-14, rat Tyr-α-calcitonin gene-related peptide (23-37), motilin and vasoactive intestinal peptide, furthermore bovine serum albumin are described. All species were iodinated by the iodogen method. The 125 I-labeled peptide products were separated by reversed-phase HPLC, the specific activities of mono-iodinated forms are near identical with the theoretical value. The labeled bovine serum albumin was separated by Sephadex G-100 gel filtration. (author)

  20. LDR vs. HDR brachytherapy for localized prostate cancer: the view from radiobiological models.

    Science.gov (United States)

    King, Christopher R

    2002-01-01

    Permanent LDR brachytherapy and temporary HDR brachytherapy are competitive techniques for clinically localized prostate radiotherapy. Although a randomized trial will likely never be conducted comparing these two forms of brachytherapy, a comparative radiobiological modeling analysis proves useful in understanding some of their intrinsic differences, several of which could be exploited to improve outcomes. Radiobiological models based upon the linear quadratic equations are presented for fractionated external beam, fractionated (192)Ir HDR brachytherapy, and (125)I and (103)Pd LDR brachytherapy. These models incorporate the dose heterogeneities present in brachytherapy based upon patient-derived dose volume histograms (DVH) as well as tumor doubling times and repair kinetics. Radiobiological parameters are normalized to correspond to three accepted clinical risk factors based upon T-stage, PSA, and Gleason score to compare models with clinical series. Tumor control probabilities (TCP) for LDR and HDR brachytherapy (as monotherapy or combined with external beam) are compared with clinical bNED survival rates. Predictions are made for dose escalation with HDR brachytherapy regimens. Model predictions for dose escalation with external beam agree with clinical data and validate the models and their underlying assumptions. Both LDR and HDR brachytherapy achieve superior tumor control when compared with external beam at conventional doses (LDR brachytherapy as boost achieves superior tumor control than when used as monotherapy. Stage for stage, both LDR and current HDR regimens achieve similar tumor control rates, in agreement with current clinical data. HDR monotherapy with large-dose fraction sizes might achieve superior tumor control compared with LDR, especially if prostate cancer possesses a high sensitivity to dose fractionation (i.e., if the alpha/beta ratio is low). Radiobiological models support the current clinical evidence for equivalent outcomes in localized

  1. SU-E-T-123: Anomalous Altitude Effect in Permanent Implant Brachytherapy Seeds

    International Nuclear Information System (INIS)

    Watt, E; Spencer, DP; Meyer, T

    2015-01-01

    Purpose: Permanent seed implant brachytherapy procedures require the measurement of the air kerma strength of seeds prior to implant. This is typically accomplished using a well-type ionization chamber. Previous measurements (Griffin et al., 2005; Bohm et al., 2005) of several low-energy seeds using the air-communicating HDR 1000 Plus chamber have demonstrated that the standard temperature-pressure correction factor, P TP , may overcompensate for air density changes induced by altitude variations by up to 18%. The purpose of this work is to present empirical correction factors for two clinically-used seeds (IsoAid ADVANTAGE™ 103 Pd and Nucletron selectSeed 125 I) for which empirical altitude correction factors do not yet exist in the literature when measured with the HDR 1000 Plus chamber. Methods: An in-house constructed pressure vessel containing the HDR 1000 Plus well chamber and a digital barometer/thermometer was pumped or evacuated, as appropriate, to a variety of pressures from 725 to 1075 mbar. Current measurements, corrected with P TP , were acquired for each seed at these pressures and normalized to the reading at ‘standard’ pressure (1013.25 mbar). Results: Measurements in this study have shown that utilization of P TP can overcompensate in the corrected current reading by up to 20% and 17% for the IsoAid Pd-103 and the Nucletron I-125 seed respectively. Compared to literature correction factors for other seed models, the correction factors in this study diverge by up to 2.6% and 3.0% for iodine (with silver) and palladium respectively, indicating the need for seed-specific factors. Conclusion: The use of seed specific altitude correction factors can reduce uncertainty in the determination of air kerma strength. The empirical correction factors determined in this work can be applied in clinical quality assurance measurements of air kerma strength for two previously unpublished seed designs (IsoAid ADVANTAGE™ 103 Pd and Nucletron selectSeed 125 I

  2. SU-E-T-123: Anomalous Altitude Effect in Permanent Implant Brachytherapy Seeds

    Energy Technology Data Exchange (ETDEWEB)

    Watt, E; Spencer, DP; Meyer, T [University of Calgary and Tom Baker Cancer Centre, Calgary, AB (Canada)

    2015-06-15

    Purpose: Permanent seed implant brachytherapy procedures require the measurement of the air kerma strength of seeds prior to implant. This is typically accomplished using a well-type ionization chamber. Previous measurements (Griffin et al., 2005; Bohm et al., 2005) of several low-energy seeds using the air-communicating HDR 1000 Plus chamber have demonstrated that the standard temperature-pressure correction factor, P{sub TP}, may overcompensate for air density changes induced by altitude variations by up to 18%. The purpose of this work is to present empirical correction factors for two clinically-used seeds (IsoAid ADVANTAGE™ {sup 103}Pd and Nucletron selectSeed {sup 125}I) for which empirical altitude correction factors do not yet exist in the literature when measured with the HDR 1000 Plus chamber. Methods: An in-house constructed pressure vessel containing the HDR 1000 Plus well chamber and a digital barometer/thermometer was pumped or evacuated, as appropriate, to a variety of pressures from 725 to 1075 mbar. Current measurements, corrected with P{sub TP}, were acquired for each seed at these pressures and normalized to the reading at ‘standard’ pressure (1013.25 mbar). Results: Measurements in this study have shown that utilization of P{sub TP} can overcompensate in the corrected current reading by up to 20% and 17% for the IsoAid Pd-103 and the Nucletron I-125 seed respectively. Compared to literature correction factors for other seed models, the correction factors in this study diverge by up to 2.6% and 3.0% for iodine (with silver) and palladium respectively, indicating the need for seed-specific factors. Conclusion: The use of seed specific altitude correction factors can reduce uncertainty in the determination of air kerma strength. The empirical correction factors determined in this work can be applied in clinical quality assurance measurements of air kerma strength for two previously unpublished seed designs (IsoAid ADVANTAGE™ {sup 103}Pd and

  3. Dose optimization in simulated permanent interstitial implant of prostate brachytherapy

    International Nuclear Information System (INIS)

    Faria, Fernando Pereira de

    2006-01-01

    Any treatment of cancer that uses some modality of radiotherapy is planned before being executed. In general the goal in radiotherapy is to irradiate the target to be treated minimizing the incidence of radiation in healthy surrounding tissues. The planning differ among themselves according to the modality of radiotherapy, the type of cancer and where it is located. This work approaches the problem of dose optimization for the planning of prostate cancer treatment through the modality of low dose-rate brachytherapy with Iodine 125 or Palladium 103 seeds. An algorithm for dose calculation and optimization was constructed to find the seeds configuration that better fits the relevant clinical criteria such as as the tolerated dose by the urethra and rectum and the desired dose for prostate. The algorithm automatically finds this configuration from the prostate geometry established in two or three dimensions by using images of ultrasound, magnetic resonance or tomography and from the establishment of minimum restrictions to the positions of the seeds in the prostate and needles in a template. Six patterns of seeds distribution based on clinical criteria were suggested and tested in this work. Each one of these patterns generated a space of possible seeds configurations for the prostate tested by the dose calculation and optimization algorithm. The configurations that satisfied the clinical criteria were submitted to a test according to an optimization function suggested in this work. The configuration that produced maximum value for this function was considered the optimized one. (author)

  4. Brachytherapy in Europe: philosophies, current practice and future directions

    International Nuclear Information System (INIS)

    Haworth, A.

    2000-01-01

    Full text: Five months sabbatical leave provided an opportunity to visit six radiotherapy centres in France, Holland and England. While brachytherapy philosophies and practices within each country were similar, there were considerable differences in attitudes between countries. The Institute Gustave Roussy, home of the Paris System and host for the French sector confirmed that the Paris System is still very much the preferred dosimetry method in this part of the world. Though their preference for low dose rate brachytherapy is still evident, high dose rate brachytherapy has found some applications but the rules of the Paris System are never far away and the words 'what about the hyperdose sleeve' are firmly implanted into this visitor's brain. The use of real time dosimetry for I-125 prostate brachytherapy at the Institute Curie (Paris) provided an interesting contrast to the standard pre and post implant dosimetry techniques commonly employed elsewhere. The two Dutch centres on the itinerary, in stark contrast to the traditional techniques seen in France, have applied the power of computers to investigate optimisation of the classic dosimetry systems and called on the analysis techniques (DVH, NTCP, TCP etc) now familiar to us all in external beam therapy. The Cookridge Hospital in England fitted somewhere between the French and Dutch centres. This centre showed how both modern and traditional techniques could be applied in an efficient way for a large variety of treatment sites. Copyright (2000) Australasian College of Physical Scientists and Engineers in Medicine

  5. Consumption of 125I labelled fibrinogen in normal subjects

    International Nuclear Information System (INIS)

    Langer, B.; Camargo, E.E.; Reis, J.M.M. dos; Carvalho, N.; Leao, L.E.P.

    1978-01-01

    The metabolism of iodine- 125 labeled human fibrinogen is studied by using three different sets of the radiopharmaceutical (0.9, 1.3 and 1.84 iodine atoms/fibrinogen molecule ratios) in 19 normal subjects. An aliquot of 40 μCi of fibrinogem- 125 I is injected in each subject, on normal dietary conditions and blood samples are withdrawn at 30, 60, 180, 36 and 720 minutes after the injection and, thereafter, one daily sample during 10 days. The compartmental distribution of the tracer is defined by plotting plasma and serum sample counts on a semilogarithmic graph paper. A rapid phase and 3 compartments are obtained. A 'rapid' consumption half-life and a 'real' consumption half-life are defined. The fibrinogen clottability is followed up to the last blood sample by checking the ratios of serum and plasma radioactivities [pt

  6. Studies in iodine metabolism. Progress report, April 1975 -- March 1976. [Rats, mice, cattle, /sup 125/I, /sup 131/I

    Energy Technology Data Exchange (ETDEWEB)

    Van Middlesworth, L.

    1976-01-01

    Investigations during the past twelve months have included the following subjects: factors which influence release of radioiodine from thyroid glands; contamination of commercially available low-iodine diets; effects of hypoxia on release of iodine from thyroid glands of rats and mice; development of practical tests for available iodine in low-iodine diets; reproduction and abnormal thyroglobulin of rats maintained on low-iodine diets; observations on radioactivity in animal thyroids; collaboration with other laboratories regarding radium in bovine thyroids.

  7. GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications

    Science.gov (United States)

    Lemaréchal, Yannick; Bert, Julien; Falconnet, Claire; Després, Philippe; Valeri, Antoine; Schick, Ulrike; Pradier, Olivier; Garcia, Marie-Paule; Boussion, Nicolas; Visvikis, Dimitris

    2015-07-01

    In brachytherapy, plans are routinely calculated using the AAPM TG43 formalism which considers the patient as a simple water object. An accurate modeling of the physical processes considering patient heterogeneity using Monte Carlo simulation (MCS) methods is currently too time-consuming and computationally demanding to be routinely used. In this work we implemented and evaluated an accurate and fast MCS on Graphics Processing Units (GPU) for brachytherapy low dose rate (LDR) applications. A previously proposed Geant4 based MCS framework implemented on GPU (GGEMS) was extended to include a hybrid GPU navigator, allowing navigation within voxelized patient specific images and analytically modeled 125I seeds used in LDR brachytherapy. In addition, dose scoring based on track length estimator including uncertainty calculations was incorporated. The implemented GGEMS-brachy platform was validated using a comparison with Geant4 simulations and reference datasets. Finally, a comparative dosimetry study based on the current clinical standard (TG43) and the proposed platform was performed on twelve prostate cancer patients undergoing LDR brachytherapy. Considering patient 3D CT volumes of 400  × 250  × 65 voxels and an average of 58 implanted seeds, the mean patient dosimetry study run time for a 2% dose uncertainty was 9.35 s (≈500 ms 10-6 simulated particles) and 2.5 s when using one and four GPUs, respectively. The performance of the proposed GGEMS-brachy platform allows envisaging the use of Monte Carlo simulation based dosimetry studies in brachytherapy compatible with clinical practice. Although the proposed platform was evaluated for prostate cancer, it is equally applicable to other LDR brachytherapy clinical applications. Future extensions will allow its application in high dose rate brachytherapy applications.

  8. GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications

    International Nuclear Information System (INIS)

    Lemaréchal, Yannick; Bert, Julien; Schick, Ulrike; Pradier, Olivier; Garcia, Marie-Paule; Boussion, Nicolas; Visvikis, Dimitris; Falconnet, Claire; Després, Philippe; Valeri, Antoine

    2015-01-01

    In brachytherapy, plans are routinely calculated using the AAPM TG43 formalism which considers the patient as a simple water object. An accurate modeling of the physical processes considering patient heterogeneity using Monte Carlo simulation (MCS) methods is currently too time-consuming and computationally demanding to be routinely used. In this work we implemented and evaluated an accurate and fast MCS on Graphics Processing Units (GPU) for brachytherapy low dose rate (LDR) applications. A previously proposed Geant4 based MCS framework implemented on GPU (GGEMS) was extended to include a hybrid GPU navigator, allowing navigation within voxelized patient specific images and analytically modeled 125 I seeds used in LDR brachytherapy. In addition, dose scoring based on track length estimator including uncertainty calculations was incorporated. The implemented GGEMS-brachy platform was validated using a comparison with Geant4 simulations and reference datasets. Finally, a comparative dosimetry study based on the current clinical standard (TG43) and the proposed platform was performed on twelve prostate cancer patients undergoing LDR brachytherapy. Considering patient 3D CT volumes of 400  × 250  × 65 voxels and an average of 58 implanted seeds, the mean patient dosimetry study run time for a 2% dose uncertainty was 9.35 s (≈500 ms 10 −6 simulated particles) and 2.5 s when using one and four GPUs, respectively. The performance of the proposed GGEMS-brachy platform allows envisaging the use of Monte Carlo simulation based dosimetry studies in brachytherapy compatible with clinical practice. Although the proposed platform was evaluated for prostate cancer, it is equally applicable to other LDR brachytherapy clinical applications. Future extensions will allow its application in high dose rate brachytherapy applications. (paper)

  9. Clinical application of iodine 123 with special consideration of radionuclide purity, measuring accuracy and radiation dose

    International Nuclear Information System (INIS)

    Hermann, H.J.; Ammon, J.; Winkel, K. zum; Haubold, U.

    1975-01-01

    Iodine 123 is a nearly 'ideal' radionuclide for thyroid imaging. The production of Iodine 123 requires cyclotrons or accelerators. The production of multicurie amounts of Iodine 123 has been suggested through the use of high-energy accelerators (> 60 MeV). Most of the methods for the production of Iodine 123 using a compact cyclotron result in contamination with f.e. Iodine 124 which reduces the spatial resolution of imaging procedures and increases the radiation dose to the patient. The radiation dose has been calculated for three methods of production. The various contamination with Iodine 124, Iodine 125 and Iodine 126 result in comparable radiation dose of Iodine 131, provided that the time between production and application is more than four half-live-times of Iodine 123. (orig.) [de

  10. A comparative study of 19-iodocholesterol-''125I 3-acetate and Na''125I in liquid scintillation measurements

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J.M.; Grau Carles, A.

    1994-01-01

    A comparative study of performance of 19-iodocholesterol-''125I 3-acetate and sodium iodine samples labelled with ''125 I is presented for liquid scintillation counting measurements. Quench effect, count rate stability and spectral evolution of samples have been followed for several weeks in Toluene, Hisafe II, Instagel, Dioxane-naphthalene and Toluene-alcohol scintillators. Organic samples have negligible quench effect in the interval of I''-concentration of 0-90 ug and inorganic samples only show a very small variation, lower than 12%, for Dioxane-naphthalene, in the same range of concentration. Satisfactory stability is obtained in general for both, organic and inorganic samples, but small counting losses, 0.03% for 19-iodocholesterol-''125I 3-acetate samples in Toluene-alcohol and 0.04% for Na''125I samples in Dioxane-naphthalene and Toluene-alcohol, have been reported. (Author) 8 refs

  11. Radioactively labelled iodinated insulin and method of preparation

    Energy Technology Data Exchange (ETDEWEB)

    Geiger, R; Teetz, V; Eckert, H G

    1977-10-20

    Suitable tracers for RIA and substrates for pharmacokinetic investigations are insulin derivatives where B1 phenylalanine is substituted by a tyrosine derivative and part of the iodine is in the form of I-125 or I-131. The preparation of the insulin derivatives is described.

  12. SU-E-T-443: Geometric Uncertainties in Eye Plaque Dosimetry for a Fully Loaded 16 Mm COMS Plaque

    International Nuclear Information System (INIS)

    Morrison, H; Menon, G; Jans, H; Larocque, M; Sloboda, R

    2015-01-01

    Purpose: To determine the effect of geometric uncertainties in the seed positions in a COMS eye plaque on the central axis (CAX) dose. Methods: A Silastic insert was placed into a photopolymer 3D printed 16 mm COMS plaque, which was then positioned onto a custom-designed PMMA eye phantom. High resolution 3D images were acquired of the setup using a Siemens Inveon microPET/CT scanner. Images were acquired with the plaque unloaded and loaded with IsoAid I-125 seed shells (lack of silver core to minimize metal artifacts). Seed positions and Silastic thickness beneath each slot were measured. The measured seed coordinates were used to alter the seed positions within a standard 16 mm COMS plaque in Plaque Simulator v5.7.3 software. Doses along the plaque CAX were compared for the original and modified plaque coordinates using 3.5 mCi seeds with treatment times set to deliver 70 Gy to tumour apexes of 3.5, 5, and 10 mm height. Results: The majority of seeds showed length-wise displacement, and all seeds showed displacement radially outward from the eye center. The average radial displacement was 0.15 mm larger than the expected 1.4 mm offset, approximately half of which was due to increased Silastic thickness beneath each slot. The CAX doses for the modified seed positions were consistently lower for all tumour heights due to geometric displacement of the seeds; dose differences were found to increase to a maximum of 2.6% at a depth of ∼10 mm, after which they decreased due to the inverse square dose fall-off minimizing this effect. Conclusion: This work presents initial results of a broader dosimetric uncertainty evaluation for fully loaded COMS eye plaques and demonstrates the effects of seed positioning uncertainties. The small shifts in seed depths had noticeable effects on the CAX doses indicating the importance of careful Silastic loading. Funding provided by Alberta Cancer Foundation Grant #26655, Vanier Canada Graduate Scholarship, and Alberta Innovates Health

  13. Assessment of I-125 seed implant accuracy when using the live-planning technique for low dose rate prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Moorrees Joshua

    2012-11-01

    Full Text Available Abstract Background Low risk prostate cancers are commonly treated with low dose rate (LDR brachytherapy involving I-125 seeds. The implementation of a ‘live-planning’ technique at the Royal Adelaide Hospital (RAH in 2007 enabled the completion of the whole procedure (i.e. scanning, planning and implant in one sitting. ‘Live-planning’ has the advantage of a more reliable delivery of the planned treatment compared to the ‘traditional pre-plan’ technique (where patient is scanned and planned in the weeks prior to implant. During live planning, the actual implanted needle positions are updated real-time on the treatment planning system and the dosimetry is automatically recalculated. The aim of this investigation was to assess the differences and clinical relevance between the planned dosimetry and the updated real-time implant dosimetry. Methods A number of 162 patients were included in this dosimetric study. A paired t-test was performed on the D90, V100, V150 and V200 target parameters and the differences between the planned and implanted dose distributions were analysed. Similarly, dosimetric differences for the organs at risk (OAR were also evaluated. Results Small differences between the primary dosimetric parameters for the target were found. Still, the incidence of hotspots was increased with approximately 20% for V200. Statistically significant increases were observed in the doses delivered to the OAR between the planned and implanted data; however, these increases were consistently below 3% thus probably without clinical consequences. Conclusions The current study assessed the accuracy of prostate implants with I-125 seeds when compared to initial plans. The results confirmed the precision of the implant technique which RAH has in place. Nevertheless, geographical misses, anatomical restrictions and needle displacements during implant can have repercussions for centres without live-planning option if dosimetric changes are not

  14. Five-year biochemical outcome following permanent interstitial brachytherapy for clinical T1-T3 prostate cancer

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Galbreath, Robert W.; Lief, Jonathan H.

    2001-01-01

    Purpose: To evaluate 5-year biochemical disease-free outcome for men with clinical T1b-T3a NxM0 1977 American Joint Committee on Cancer (1997 AJCC) adenocarcinoma of the prostate gland who underwent transperineal ultrasound-guided permanent prostate brachytherapy. Methods and Materials: Four hundred twenty-five patients underwent transperineal ultrasound-guided prostate brachytherapy using either 103 Pd or 125 I, for clinical T1b-T3a NxM0 (1997 AJCC) adenocarcinoma of the prostate gland, from April 1995 to October 1999. No patient underwent pathologic lymph-node staging. One hundred ninety patients were implanted with either 103 Pd or 125 I monotherapy; 235 patients received moderate-dose external beam radiation therapy (EBRT), followed by a prostate brachytherapy boost; 163 patients received neoadjuvant hormonal manipulation, in conjunction with either 103 Pd or 125 I monotherapy (77 patients) or in conjunction with moderate-dose EBRT and a prostate brachytherapy boost (86 patients). The median patient age was 68.0 years (range, 48.2-81.3 years). The median follow-up was 31 months (range, 11-69 months). Follow-up was calculated from the day of implantation. No patient was lost to follow-up. Biochemical disease-free survival was defined by the American Society of Therapeutic Radiation and Oncology (ASTRO) consensus definition. Results: For the entire cohort, the 5-year actuarial biochemical no evidence of disease (bNED) survival rate was 94%. For patients with low-, intermediate-, and high-risk disease, the 5-year biochemical disease-free rates were 97.1%, 97.5%, and 84.4%, respectively. For hormone-naive patients, 95.7%, 96.4%, and 79.9% of patients with low-, intermediate-, and high-risk disease were free of biochemical failure. Clinical and treatment parameters predictive of biochemical outcome included: clinical stage, pretreatment prostate-specific antigen (PSA), Gleason score, risk group, age > 65 years, and neoadjuvant hormonal therapy. Isotope choice was

  15. Microdosimetry of astatine-211 and comparison with that of iodine-125

    International Nuclear Information System (INIS)

    Unak, T.

    2001-01-01

    211 At is an alpha and Auger emitter radionuclide and has been frequently used for labeling of different kind of chemical agents. 125 I is also known as an effective Auger emitter. The radionuclides which emit short range and high LET radiations such as alpha particles and Auger electrons have high radiotoxic effectiveness on the living systems. The microdosimetric data are suitable to clarify the real radiotoxic effectiveness and to get the detail of diagnostic and therapeutic application principles of these radionuclides. In this study, the energy and dose absorptions by cell nucleus from alpha particles and Auger electrons emitted by 211 At have been calculated using a Monte Carlo calculation program (code: UNMOC). For these calculations two different model corresponding to the cell nucleus have been used and the data obtained were compared with the data earlier obtained for 125 I. As a result, the radiotoxicity of 211 At is in the competition with 125 I. In the case of a specific agent labelled with 211 At or 125 I is incorporated into the cell or cell nucleus, but non-bound to DNA or not found very close to it, 211 At should considerably be much more radiotoxic than 125 I, but in the case of the labelled agent is bound to DNA or take a place very close to it, the radiotoxicity of 125 I should considerably be higher than 211 At. (author)

  16. Synthesis of the 123I- and 125I-labeled cholinergic nerve marker (-)-5-iodobenzovesamicol

    International Nuclear Information System (INIS)

    Van Dort, M.E.; Jung, Y.-W.; Gildersleeve, D.L.; Hagen, C.A.; Kuhl, D.E.; Wieland, D.M.

    1993-01-01

    The highly toxic curaremimetic and cholinergic neuron marker (-)-5-iodobenzovesamicol (IBVM) has been labeled with iodine-125 and iodine-123. [ 125 I]IBVM, suitable for animal distribution and ex vivo autoradiographic studies, was synthesized by solid-state exchanger; isolated yields were 65-89% with specific activities in the range of 130-200 Ci/mmol. The synthesis of no-carrier-added (-)-5-[ 125 I]IBVM from the corresponding chiral (-)-5-(tri-n-butyltin) derivative using Na 125 I was evaluated using the oxidants H 2 O 2 , peracetic acid and chloramine-T. Both peracetic acid and chloramine-T gave good yields (70-95%). However, when Na 123 I was utilized, acceptable yields of [ 123 I]IBVM were obtained only with chloramine-T. Distribution analyses of [ 125 I]IBVM and [ 123 I]IBVM in mice 4 h following intravenous administration show essentially equivalent concentrations of the two tracers in the four brain regions sampled. The exceptionally high specific activity of [ 123 I]IBVM has made possible the evaluation of this radiotracer in humans. (Author)

  17. TU-AB-BRC-08: Egs-brachy, a Fast and Versatile Monte Carlo Code for Brachytherapy Applications

    Energy Technology Data Exchange (ETDEWEB)

    Chamberland, M; Taylor, R; Rogers, D; Thomson, R [Carleton University, Ottawa, ON (Canada)

    2016-06-15

    Purpose: To introduce egs-brachy, a new, fast, and versatile Monte Carlo code for brachytherapy applications. Methods: egs-brachy is an EGSnrc user-code based on the EGSnrc C++ class library (egs++). Complex phantom, applicator, and source model geometries are built using the egs++ geometry module. egs-brachy uses a tracklength estimator to score collision kerma in voxels. Interaction, spectrum, energy fluence, and phase space scoring are also implemented. Phase space sources and particle recycling may be used to improve simulation efficiency. HDR treatments (e.g. stepping source through dwell positions) can be simulated. Standard brachytherapy seeds, as well as electron and miniature x-ray tube sources are fully modelled. Variance reduction techniques for electron source simulations are implemented (Bremsstrahlung cross section enhancement, uniform Bremsstrahlung splitting, and Russian Roulette). TG-43 parameters of seeds are computed and compared to published values. Example simulations of various treatments are carried out on a single 2.5 GHz Intel Xeon E5-2680 v3 processor core. Results: TG-43 parameters calculated with egs-brachy show excellent agreement with published values. Using a phase space source, 2% average statistical uncertainty in the PTV ((2mm){sup 3} voxels) can be achieved in 10 s for 100 {sup 125}I or {sup 103}Pd seeds in a 36.2 cm{sup 3} prostate PTV, 31 s for 64 {sup 103}Pd seeds in a 64 cm{sup 3} breast PTV, and 56 s for a miniature x-ray tube in a 27 cm{sup 3} breast PTV. Comparable uncertainty is reached in 12 s in a (1 mm){sup 3} water voxel 5 mm away from a COMS 16mm eye plaque with 13 {sup 103}Pd seeds. Conclusion: The accuracy of egs-brachy has been demonstrated through benchmarking calculations. Calculation times are sufficiently fast to allow full MC simulations for routine treatment planning for diverse brachytherapy treatments (LDR, HDR, miniature x-ray tube). egs-brachy will be available as free and open-source software to the

  18. TU-AB-BRC-08: Egs-brachy, a Fast and Versatile Monte Carlo Code for Brachytherapy Applications

    International Nuclear Information System (INIS)

    Chamberland, M; Taylor, R; Rogers, D; Thomson, R

    2016-01-01

    Purpose: To introduce egs-brachy, a new, fast, and versatile Monte Carlo code for brachytherapy applications. Methods: egs-brachy is an EGSnrc user-code based on the EGSnrc C++ class library (egs++). Complex phantom, applicator, and source model geometries are built using the egs++ geometry module. egs-brachy uses a tracklength estimator to score collision kerma in voxels. Interaction, spectrum, energy fluence, and phase space scoring are also implemented. Phase space sources and particle recycling may be used to improve simulation efficiency. HDR treatments (e.g. stepping source through dwell positions) can be simulated. Standard brachytherapy seeds, as well as electron and miniature x-ray tube sources are fully modelled. Variance reduction techniques for electron source simulations are implemented (Bremsstrahlung cross section enhancement, uniform Bremsstrahlung splitting, and Russian Roulette). TG-43 parameters of seeds are computed and compared to published values. Example simulations of various treatments are carried out on a single 2.5 GHz Intel Xeon E5-2680 v3 processor core. Results: TG-43 parameters calculated with egs-brachy show excellent agreement with published values. Using a phase space source, 2% average statistical uncertainty in the PTV ((2mm)"3 voxels) can be achieved in 10 s for 100 "1"2"5I or "1"0"3Pd seeds in a 36.2 cm"3 prostate PTV, 31 s for 64 "1"0"3Pd seeds in a 64 cm"3 breast PTV, and 56 s for a miniature x-ray tube in a 27 cm"3 breast PTV. Comparable uncertainty is reached in 12 s in a (1 mm)"3 water voxel 5 mm away from a COMS 16mm eye plaque with 13 "1"0"3Pd seeds. Conclusion: The accuracy of egs-brachy has been demonstrated through benchmarking calculations. Calculation times are sufficiently fast to allow full MC simulations for routine treatment planning for diverse brachytherapy treatments (LDR, HDR, miniature x-ray tube). egs-brachy will be available as free and open-source software to the medical physics research community. This

  19. Effect of photon energy spectrum on dosimetric parameters of brachytherapy sources.

    Science.gov (United States)

    Ghorbani, Mahdi; Mehrpouyan, Mohammad; Davenport, David; Ahmadi Moghaddas, Toktam

    2016-06-01

    The aim of this study is to quantify the influence of the photon energy spectrum of brachytherapy sources on task group No. 43 (TG-43) dosimetric parameters. Different photon spectra are used for a specific radionuclide in Monte Carlo simulations of brachytherapy sources. MCNPX code was used to simulate 125I, 103Pd, 169Yb, and 192Ir brachytherapy sources. Air kerma strength per activity, dose rate constant, radial dose function, and two dimensional (2D) anisotropy functions were calculated and isodose curves were plotted for three different photon energy spectra. The references for photon energy spectra were: published papers, Lawrence Berkeley National Laboratory (LBNL), and National Nuclear Data Center (NNDC). The data calculated by these photon energy spectra were compared. Dose rate constant values showed a maximum difference of 24.07% for 103Pd source with different photon energy spectra. Radial dose function values based on different spectra were relatively the same. 2D anisotropy function values showed minor differences in most of distances and angles. There was not any detectable difference between the isodose contours. Dosimetric parameters obtained with different photon spectra were relatively the same, however it is suggested that more accurate and updated photon energy spectra be used in Monte Carlo simulations. This would allow for calculation of reliable dosimetric data for source modeling and calculation in brachytherapy treatment planning systems.

  20. Fifteen-Year Biochemical Relapse-Free Survival, Cause-Specific Survival, and Overall Survival Following I125 Prostate Brachytherapy in Clinically Localized Prostate Cancer: Seattle Experience

    International Nuclear Information System (INIS)

    Sylvester, John E.; Grimm, Peter D.; Wong, Jason; Galbreath, Robert W.; Merrick, Gregory; Blasko, John C.

    2011-01-01

    Purpose: To report 15-year biochemical relapse-free survival (BRFS), cause-specific survival (CSS), and overall survival (OS) outcomes of patients treated with I 125 brachytherapy monotherapy for clinically localized prostate cancer early in the Seattle experience. Methods and Materials: Two hundred fifteen patients with clinically localized prostate cancer were consecutively treated from 1988 to 1992 with I 125 monotherapy. They were prospectively followed as a tight cohort. They were evaluated for BRFS, CSS, and OS. Multivariate analysis was used to evaluate outcomes by pretreatment clinical prognostic factors. BRFS was analyzed by the Phoenix (nadir + 2 ng/mL) definition. CSS and OS were evaluated by chart review, death certificates, and referring physician follow-up notes. Gleason scoring was performed by general pathologists at a community hospital in Seattle. Time to biochemical failure (BF) was calculated and compared by Kaplan-Meier plots. Results: Fifteen-year BRFS for the entire cohort was 80.4%. BRFS by D'Amico risk group classification cohort analysis was 85.9%, 79.9%, and 62.2% for low, intermediate, and high-risk patients, respectively. Follow-up ranged from 3.6 to 18.4 years; median follow-up was 15.4 years for biochemically free of disease patients. Overall median follow-up was 11.7 years. The median time to BF in those who failed was 5.1 years. CSS was 84%. OS was 37.1%. Average age at time of treatment was 70 years. There was no significant difference in BRFS between low and intermediate risk groups. Conclusion: I 125 monotherapy results in excellent 15-year BRFS and CSS, especially when taking into account the era of treatment effect.

  1. American brachytherapy society (ABS) consensus guidelines for brachytherapy of esophageal cancer

    International Nuclear Information System (INIS)

    Gaspar, Laurie E.; Nag, Subir; Herskovic, Arnold; Mantravadi, Rao; Speiser, Burton

    1997-01-01

    Introduction: There is wide variation in the indications, treatment regimens, and dosimetry for brachytherapy in the treatment of cancer of the esophagus. No guidelines for optimal therapy currently exist. Methods and Materials: Utilizing published reports and clinical experience, representatives of the Clinical Research Committee of the American Brachytherapy Society (ABS) formulated guidelines for brachytherapy in esophageal cancer. Results: Recommendations were made for brachytherapy in the definitive and palliative treatment of esophageal cancer. (A) Definitive treatment: Good candidates for brachytherapy include patients with unifocal thoracic adeno- or squamous cancers ≤ 10 cm in length, with no evidence of intra-abdominal or metastatic disease. Contraindications include tracheal or bronchial involvement, cervical esophagus location, or stenosis that cannot be bypassed. The esophageal brachytherapy applicator should have an external diameter of 6-10 mm. If 5FU-based chemotherapy and 45-50-Gy external beam are used, recommended brachytherapy is either: (i) HDR 10 Gy in two weekly fractions of 5 Gy each; or (ii) LDR 20 Gy in a single course at 0.4-1 Gy/hr. All doses are specified 1 cm from the midsource or middwell position. Brachytherapy should follow external beam radiation therapy and should not be given concurrently with chemotherapy. (B) Palliative treatment: Patients with adeno- or squamous cancers of the thoracic esophagus with distant metastases or unresectable local disease progression/recurrence after definitive radiation treatment should be considered for brachytherapy with palliative intent. After limited dose (30 Gy) EBRT, the recommended brachytherapy is either: (i) HDR 10-14 Gy in one or two fractions; or (ii) LDR 20-25 Gy in a single course at 0.4-1 Gy/hr. The need for external beam radiation in newly diagnosed patients with a life expectancy of less than 3 months is controversial. In these cases, HDR of 15-20 Gy in two to four fractions or

  2. Monte Carlo calculated microdosimetric spread for cell nucleus-sized targets exposed to brachytherapy 125I and 192Ir sources and 60Co cell irradiation.

    Science.gov (United States)

    Villegas, Fernanda; Tilly, Nina; Ahnesjö, Anders

    2013-09-07

    The stochastic nature of ionizing radiation interactions causes a microdosimetric spread in energy depositions for cell or cell nucleus-sized volumes. The magnitude of the spread may be a confounding factor in dose response analysis. The aim of this work is to give values for the microdosimetric spread for a range of doses imparted by (125)I and (192)Ir brachytherapy radionuclides, and for a (60)Co source. An upgraded version of the Monte Carlo code PENELOPE was used to obtain frequency distributions of specific energy for each of these radiation qualities and for four different cell nucleus-sized volumes. The results demonstrate that the magnitude of the microdosimetric spread increases when the target size decreases or when the energy of the radiation quality is reduced. Frequency distributions calculated according to the formalism of Kellerer and Chmelevsky using full convolution of the Monte Carlo calculated single track frequency distributions confirm that at doses exceeding 0.08 Gy for (125)I, 0.1 Gy for (192)Ir, and 0.2 Gy for (60)Co, the resulting distribution can be accurately approximated with a normal distribution. A parameterization of the width of the distribution as a function of dose and target volume of interest is presented as a convenient form for the use in response modelling or similar contexts.

  3. Hospitalary inventory of prostatic sources of I-125; Inventario hospitalario de fuentes prostaticas de I-125

    Energy Technology Data Exchange (ETDEWEB)

    Barquero Sanz, R.; Anton, D.; Frutos Baraja, J. de.; Castillo Belmonte, A. del; Alonso, D.; Miquel, D. de; Lopez Lara-Martin, F.

    2013-07-01

    In accordance with the current regulations for radioactive facilities of brachytherapy, to carry out treatments of Prostate with I-125, must be a safety study involving evaluate maximum sources activity to use in the implants. In our installation was requested to perform implants permanent interstitial in prostate patients who tend to leaving the hospital in the hours following the intervention. The request which was prepared taking into account the maximum number predictable treatment (two per week), and to determine the activity to request, it was made the removal of seeds surplus by the supplier after each treatment. (Author)

  4. Iodine-125-labelled tamoxifen is differentially cytoxic to cells containing oestrogen receptors

    International Nuclear Information System (INIS)

    Bloomer, W.D.; McLaughlin, W.H.; Weichselbaum, R.R.

    1980-01-01

    Tamoxifen, a non-steroidal anti-oestrogen competes with 17 - oestradiol for oestrogen receptor protein and is translocated to the nucleus. Carrier-free 125 I-TAM was tested for cytotoxicity in oestrogen receptor rich (human breast cancer MCF-7) and poor (V-79 Chinese hamster) cells. 125 I-TAM was differentially cytotoxic to MCF-7 cells. The D 37 values for MCF-7 and V-79 cells were 0.5 and 1.5 pCi/cell respectively. No radiotoxicity was observed with Na 125 I at doses equal to 125 I-TAM; iodide was effectively excluded from both cell lines and remained in the extracellular space. Also, nonradioactive 127 I-TAM and TAM were both non-toxic when tested at levels comparable to 125 I-TAM. It is suggested that the marked cytotoxicity in MCF-7 cells results from close approximation of 125 I with the genetic apparatus as a result of direct charging of specific nuclear receptors and/or translocation of 125 I-TAM receptor complexes from the cytoplasm to the nucleus, and that the minimal toxicity in V-79 cells reflects transmitted cytoplasmic radiation effects, limited direct nuclear charging and/or limited nuclear translocation resulting from the relative paucity of oestrogen in the cells. (U.K.)

  5. Intestinal morphological effect of brachytherapy of low rate of dose, administrated in therapeutic form and its clinical manifestations in uterine cervix tumors

    International Nuclear Information System (INIS)

    Mendoza, Carmen; Contreras, Manuel

    2005-01-01

    Brachytherapy is effective to eradicate cancer in the cervix, in order to obtain the control of disease we use high dose with vesical and rectum toxicity. The objective is to investigate if brachytherapy by itself is the cause of intestinal damage, to know in addition if the intensity of the clinic manifestations is in direct relation to the given radiation dose and this gets worse when it is received in several applications. Hypothesis: The intensity of the radiation with brachytherapy of low rate of dose is proportional to the degree of clinical manifestations and morphologic damage of the intestine. A prospective analysis was made inpatients with cancer of cervix from september 2000 to june 2004. Each patient who enters to the department of brachytherapy of the hospital must be done laboratory examination that includes plaque and coagulation test before being accepted. We use the clinical card and a table in order to register data concerning teletherapy, implants of brachytherapy of low rate of dose, symptoms of intestinal toxicity and details of colonoscopia. Subsequent to the hospitable discharge the patient is sent to gastroenterology for clinical evaluation and to realize colonoscopia. From september 2000 to june 2004, 540 patients entered, 80 patients (15%) displayed intestinal manifestations, all received teletherapy and brachytherapy, nobody else received brachytherapy in exclusive form and only one patient (0.1%) received the total of the dose in 2 applications. The equipment of teletherapy Primus with energy of 6 and 18 Mv and implants of brachytherapy Manchester were used (70/55 patients). 79 (98%) patients received dose between 85-75 Gy in one single application, 58 (72%) received the total of the dose to the tumor, 21 (26%) in vaginal mucosa. Discussion: Brachytherapy is the cause of the damages in the intestinal mucosa. (The author)

  6. Carcinoma of the prostate treated by pelvic node dissection, iodine-125 seed implant and external irradiation; a study of rectal complications

    Energy Technology Data Exchange (ETDEWEB)

    Abadir, R.; Ross, G. Jr.; Weinstein, S.H. (Missouri Univ., Columbia (USA). Hospital and Clinics)

    1984-09-01

    The University of Missouri-Columbia protocol for localised cancer of the prostate calls for pelvic node dissection, 10 000 cGy at the periphery of the prostate from /sup 125/I and 4000 cGy in 20 fractions to the whole pelvis using supervoltage X-ray therapy. Rectal complications were studied in 104 patients; acute and chronic reactions were defined. During external irradiation 54% did not develop diarrhoea, 43% had mild diarrhoea and 3% had severe diarrhoea. In the chronic stage 77% did not have diarrhoea, 12% had delayed, non-distressing rectal bleeding which did not need specific treatment or needed only simple treatment, 7% had prolonged distressing proctitis and 4% had rectal ulceration or recto-urethral fistula necessitating colostomy. Each of the four patients who had colostomy had an additional aetiological factor (arterial disease, pelvic inflammation, additional radiation, pelvic malignancy or second operation). None of the patients entered in the combined brachytherapy and teletherapy programme, and in whom 0.5 cm space was maintained between the closest seed and the rectal mucosa, developed prolonged proctitis.

  7. Preparation of 125I labelled compound

    International Nuclear Information System (INIS)

    Rafii, H.; Beiki, D.; Matlubi, M.; Jalilian, A.R.; Motamedi, F.; Karimian, A.R.; Najafi, R.; Babaei, M.; Kamali Dehghan, M.; Shah-Hossaini, G.R.; Shafahi, S.K.; Keshavarzi, F.

    2002-01-01

    Iodinated compounds with 131 I, 125 I and 123 I have been widely used for biochemical function studies. In conjunction with SPECT, [ 123 I] labelled proteins have various diagnostic and therapeutic applications in nuclear medicine. In this study, synthesis and quality control of [ 18 F]radiofluorinated and radioiodinated of some proteins and peptides as well as their biological behaviors are considered to be investigated. (author)

  8. Fabrication and characterization of surface barrier detector from commercial silicon substrate

    International Nuclear Information System (INIS)

    Silva, Julio Batista Rodrigues

    2016-01-01

    In this work it was developed radiation detectors silicon surface barrier that were capable of detecting the presence of gamma radiation from a low energy of iodine-125 seeds used in brachytherapy treatments. >From commercial silicon substrates detectors were developed, one sequence left of chemical treatments to the surfaces of these substrates with the intention of minimizing the possible noise generated, validation of the samples obtained as diodes, ensuring detector characteristics and effective use as detector for Iodine-125 radioactive sources with energy of about 25 keV and Americium-251 with energy on the order of 59 keV. Finished performing the analysis of the obtained energy spectra and so it was possible to observe the ability of these detectors to measure the energy from these seeds. (author)

  9. Labelling of olive oil with radioactive iodine and radioactive technetium

    International Nuclear Information System (INIS)

    Al-Dayel, O.A.F.

    1988-03-01

    Investigates labelling of olive oil with 125 iodine and with the radioactive 99mTC. A radio analytical study for 99Mo-99mTC generator is also presented. Iodine monochloride and chlormine-T methods are used for labelling olive oil and oleic acid with radioactive iodine. Diethyl ether, benzene and n-heptane have been used as solvents, with diethyl ether giving best results using iodine monochloride method. Infrared spectroscopic studies show that labelling took place at the double bond. Use of milked 99mTc gave very low yield only. A fairly higher labelling yield was achieved when 20 mg of tin chloride has been added in acetone medium than diethyl ether medium. Thin layer chromatography and paper chromatography technique were used as quality control systems. The labelled oil can be used for diagnostic and study purposes. 140 Ref

  10. A comparative study on the iodine-labeled methods of protein and polypeptide

    International Nuclear Information System (INIS)

    Li Huaifen; Niu Huisheng; Yuan Mingyue; Yu Jinghua

    1994-01-01

    There are three methods: chloramine-T, Iodogen and lactoperoxidase(LPO). 125 I-ACTH, 125 I-insulin and 125 I-HSA are prepared by these techniques. The results show that lactoperoxidase is isolated and purified from fresh milk, meanwhile, the enzyme is used in experiments of 125 I-labeled protein, peptide hormone and mono-clone antibody, etc. LPO is a very successful method for it's mild, complete reaction, controllable, high labelling yield, higher purity of iodine-labeled compound and so on. It remains biological activation and stable character more than other two techniques

  11. Late Urinary Side Effects 10 Years After Low-Dose-Rate Prostate Brachytherapy: Population-Based Results From a Multiphysician Practice Treating With a Standardized Protocol and Uniform Dosimetric Goals

    International Nuclear Information System (INIS)

    Keyes, Mira; Miller, Stacy; Pickles, Tom; Halperin, Ross; Kwan, Winkle; Lapointe, Vincent; McKenzie, Michael; Spadinger, Ingrid; Pai, Howard; Chan, Elisa K.; Morris, W. James

    2014-01-01

    Purpose: To determine late urinary toxicity (>12 months) in a large cohort of uniformly treated low-dose-rate prostate brachytherapy patients. Methods and Materials: From 1998 to 2009, 2709 patients with National Comprehensive Cancer Network–defined low-risk and low-tier intermediate-risk prostate cancer were treated with Iodine 125 ( 125 I) low-dose-rate prostate brachytherapy; 2011 patients with a minimum of 25 months of follow-up were included in the study. Baseline patients, treatment, implant factors, and late urinary toxicity (Radiation Therapy Oncology Group [RTOG] grading system and International Prostate Symptom Score [IPSS]) were recorded prospectively. Time to IPSS resolution, late RTOG genitourinary toxicity was examined with Kaplan-Meier and log-rank tests. Cox proportional hazards regression was done for individual covariates and multivariable models. Results: Median follow-up was 54.5 months (range, 2-13 years). Actuarial toxicity rates reached 27% and 10% (RTOG ≥2 and ≥3, respectively) at 9-13 years. Symptoms resolved quickly in the majority of patients (88% in 6-12 months). The prevalence of RTOG 0, 1, 2, 3, and 4 toxicity with a minimum of 7 years' follow-up was 70%, 21%, 6.4%, 2.3%, and 0.08%, respectively. Patients with a larger prostate volume, higher baseline IPSS, higher D90, acute toxicity, and age >70 years had more late RTOG ≥2 toxicity (all P≤.02). The IPSS resolved slower in patients with lower baseline IPSS and larger ultrasound prostate volume, those not receiving androgen deprivation therapy, and those with higher D90. The crude rate of RTOG 3 toxicity was 6%. Overall the rate of transurethral resection of the prostate was 1.9%; strictures, 2%; incontinence, 1.3%; severe symptoms, 1.8%; late catheterization, 1.3%; and hematuria, 0.8%. The majority (80%) resolved their symptoms in 6-12 months. Conclusion: Long-term urinary toxicity after brachytherapy is low. Although actuarial rates increase with longer follow

  12. Late Urinary Side Effects 10 Years After Low-Dose-Rate Prostate Brachytherapy: Population-Based Results From a Multiphysician Practice Treating With a Standardized Protocol and Uniform Dosimetric Goals

    Energy Technology Data Exchange (ETDEWEB)

    Keyes, Mira, E-mail: mkeyes@bccancer.bc.ca; Miller, Stacy; Pickles, Tom; Halperin, Ross; Kwan, Winkle; Lapointe, Vincent; McKenzie, Michael; Spadinger, Ingrid; Pai, Howard; Chan, Elisa K.; Morris, W. James

    2014-11-01

    Purpose: To determine late urinary toxicity (>12 months) in a large cohort of uniformly treated low-dose-rate prostate brachytherapy patients. Methods and Materials: From 1998 to 2009, 2709 patients with National Comprehensive Cancer Network–defined low-risk and low-tier intermediate-risk prostate cancer were treated with Iodine 125 ({sup 125}I) low-dose-rate prostate brachytherapy; 2011 patients with a minimum of 25 months of follow-up were included in the study. Baseline patients, treatment, implant factors, and late urinary toxicity (Radiation Therapy Oncology Group [RTOG] grading system and International Prostate Symptom Score [IPSS]) were recorded prospectively. Time to IPSS resolution, late RTOG genitourinary toxicity was examined with Kaplan-Meier and log-rank tests. Cox proportional hazards regression was done for individual covariates and multivariable models. Results: Median follow-up was 54.5 months (range, 2-13 years). Actuarial toxicity rates reached 27% and 10% (RTOG ≥2 and ≥3, respectively) at 9-13 years. Symptoms resolved quickly in the majority of patients (88% in 6-12 months). The prevalence of RTOG 0, 1, 2, 3, and 4 toxicity with a minimum of 7 years' follow-up was 70%, 21%, 6.4%, 2.3%, and 0.08%, respectively. Patients with a larger prostate volume, higher baseline IPSS, higher D90, acute toxicity, and age >70 years had more late RTOG ≥2 toxicity (all P≤.02). The IPSS resolved slower in patients with lower baseline IPSS and larger ultrasound prostate volume, those not receiving androgen deprivation therapy, and those with higher D90. The crude rate of RTOG 3 toxicity was 6%. Overall the rate of transurethral resection of the prostate was 1.9%; strictures, 2%; incontinence, 1.3%; severe symptoms, 1.8%; late catheterization, 1.3%; and hematuria, 0.8%. The majority (80%) resolved their symptoms in 6-12 months. Conclusion: Long-term urinary toxicity after brachytherapy is low. Although actuarial rates increase with longer

  13. Radiation exposure after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Cattani, Federica; Vavassori, Andrea; Polo, Alfredo; Rondi, Elena; Cambria, Raffaella; Orecchia, Roberto; Tosi, Giampiero

    2006-01-01

    Background and purpose: Limited information is available on the true radiation exposure and associated risks for the relatives of the patients submitted to prostate brachytherapy with permanent implant of radioactive sources and for any other people coming into contact with them. In order to provide appropriate information, we analyzed the radiation exposure data from 216 prostate cancer patients who underwent 125 I or 103 Pd implants at the European Institute of Oncology of Milan, Italy. Patients and methods: Between October 1999 and October 2004, 216 patients with low risk prostate carcinoma were treated with 125 I (200 patients) or 103 Pd (16 patients) permanent seed implantation. One day after the procedure, radiation exposure measurements around the patients were performed using an ionization chamber survey meter (Victoreen RPO-50) calibrated in dose rate at an accredited calibration center (calibration Centre SIT 104). Results: The mean dose rate at the posterior skin surface (gluteal region) following 125 I implants was 41.3 μSv/h (range: 6.2-99.4 μSv/h) and following 103 Pd implants was 18.9 μSv/h (range 5.0-37.3 μSv/h). The dose rate at 50 cm from the skin decreased to the mean value of 6.4 μSv/h for the 125 I implants and to the mean value of 1.7 μSv/h for the 103 Pd implants. Total times required to reach the annual dose limit (1 mSv/year) recommended for the general population by the European Directive 96/29/Euratom and by the Italian law (Decreto Legislativo 241/2000) at a distance of 50 cm from the posterior skin surface of the implanted patient would be 7.7 and 21.6 days for 125 I and for 103 Pd. Good correlation between the measured dose rates and both the total implanted activity and the distance between the most posteriorly implanted seed and the skin surface of the patients was found. Conclusions: Our data show that the dose rates at 50 cm away from the prostate brachytherapy patients are very low and that the doses possibly absorbed by the

  14. Epoxy resins used to seal brachytherapy seed

    International Nuclear Information System (INIS)

    Ferreira, Natalia Carolina Camargos; Ferraz, Wilmar Barbosa; Reis, Sergio Carneiro dos; Santos, Ana Maria Matildes dos

    2013-01-01

    Prostate cancer treatment with brachytherapy is recommended for patients with cancer at an early stage. In this treatment, small radioactive seeds are implanted directly in the prostate gland. These seeds are composed at least of one radionuclide carrier and an X-ray marker enclosed within a metallic tube usually sealed by laser process. This process is expensive and, furthermore, it can provoke a partial volatilization of the radionuclide and change the isotropy in dose distribution around the seed. In this paper, we present a new sealing process using epoxy resin. Three kinds of resins were utilized and characterized by scanning electron microscopy (SEM), energy dispersive X ray (EDS) and by differential scanning calorimetry (DSC) after immersion in simulated body fluid (SBF) and in sodium iodine solution (NaI). The sealing process showed excellent potential to replace the sealing laser usually employed. (author)

  15. American brachytherapy society (ABS) guidelines for brachytherapy of esophageal cancer

    International Nuclear Information System (INIS)

    Nag, Subir; Gaspar, Laurie; Herskovic, Arnold; Mantravadi, Prasad; Speiser, Burton

    1996-01-01

    Introduction: There is wide variation in the indications, techniques, treatment regimens and dosimetry being used to treat cancer of the esophagus and no guidelines exist for optimal therapy. Methods: The Clinical Research Committee of the ABS met to formulate consensus guidelines for brachytherapy in esophageal cancer. Results: Good candidates for brachytherapy include patients with unifocal disease, with thoracic tumor 10 cm primary regional lymph adenopathy or tumor located in the gastro-esophageal junction or cervical esophagus. Contraindications include tracheo-esophageal fistula or stenosis that cannot be by-passed. The esophageal or nasogastric tube inserted should have a diameter of 6-10 mm whenever possible. If 5FU-based chemotherapy and 50 Gy external beam (EBRT) are used, it is suggested that the low dose rate brachytherapy (LDR) dose be 20 Gy at 0.4-1 Gy/hr, prescribed at 1 cm from the source. If high dose rate (HDR) is used, the dose recommended is 10 Gy in 2 weekly fractions of 5 Gy each, given after EBRT. Chemotherapy is not usually given concurrently with brachytherapy, and when it is, the brachytherapy dose is reduced. The length of esophagus treated by brachytherapy includes the post-EBRT involved area and a 1-2 cm margin proximally and distally. Supportive care, given during EBRT includes an antifungal agent (e.g., diflucan) and carafate. Gradual dilatation of the esophagus is required post-treatment for esophageal strictures. Conclusion: Guidelines were developed for brachytherapy in esophageal cancer. As more clinical data becomes available, these guidelines will be updated by the ABS

  16. Dose to the Bladder Neck Is the Most Important Predictor for Acute and Late Toxicity After Low-Dose-Rate Prostate Brachytherapy: Implications for Establishing New Dose Constraints for Treatment Planning

    Energy Technology Data Exchange (ETDEWEB)

    Hathout, Lara; Folkert, Michael R.; Kollmeier, Marisa A.; Yamada, Yoshiya [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Cohen, Gil' ad N. [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Zelefsky, Michael J., E-mail: zelefskm@mskcc.org [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States)

    2014-10-01

    Purpose: To identify an anatomic structure predictive for acute (AUT) and late (LUT) urinary toxicity in patients with prostate cancer treated with low-dose-rate brachytherapy (LDR) with or without external beam radiation therapy (EBRT). Methods and Materials: From July 2002 to January 2013, 927 patients with prostate cancer (median age, 66 years) underwent LDR brachytherapy with Iodine 125 (n=753) or Palladium 103 (n=174) as definitive treatment (n=478) and as a boost (n=449) followed by supplemental EBRT (median dose, 50.4 Gy). Structures contoured on the computed tomographic (CT) scan on day 0 after implantation included prostate, urethra, bladder, and the bladder neck, defined as 5 mm around the urethra between the catheter balloon and the prostatic urethra. AUT and LUT were assessed with the Common Terminology Criteria for Adverse Events, version4. Clinical and dosimetric factors associated with AUT and LUT were analyzed with Cox regression and receiver operating characteristic analysis to calculate area under the receiver operator curve (ROC) (AUC). Results: Grade ≥2 AUT and grade ≥2 LUT occurred in 520 patients (56%) and 154 patients (20%), respectively. No grade 4 toxicities were observed. Bladder neck D2cc retained a significant association with AUT (hazard ratio [HR], 1.03; 95% confidence interval [CI], 1.03-1.04; P<.0001) and LUT (HR, 1.01; 95% CI, 1.00-1.03; P=.014) on multivariable analysis. In a comparison of bladder neck with the standard dosimetric variables by use of ROC analysis (prostate V100 >90%, D90 >100%, V150 >60%, urethra D20 >130%), bladder neck D2cc >50% was shown to have the strongest prognostic power for AUT (AUC, 0.697; P<.0001) and LUT (AUC, 0.620; P<.001). Conclusions: Bladder neck D2cc >50% was the strongest predictor for grade ≥2 AUT and LUT in patients treated with LDR brachytherapy. These data support inclusion of bladder neck constraints into brachytherapy planning to decrease urinary toxicity.

  17. Radiological protection of patients in brachytherapy

    International Nuclear Information System (INIS)

    Sacc, Ricardo; Herrero, Flavia

    2008-01-01

    Full text: The prefix 'brachy' means short-range, so brachytherapy is the administration of radiation therapy using small radioactive sources in the form of needles, tubes, wires or seeds, which are placed within the tumor -interstitial form- or very near of it, superficially or in an endo-cavity form. This technique, which was limited by the size of the primary tumor, has the advantage, that the radiation, can be adjusted to the size and shape of the tumor volume and the radioisotope used, - short range -, is selected with the criteria of getting the dose in the organs at risk, as low as possible, making what it is known as conformal radiotherapy. Radioactive sources may be permanent or temporary implants. The application of radioactive material, can be manually or automatically. In the first case, a major breakthrough from the radioprotection point of view, was the use of afterloading devices, methodology highly recommended to reduce the radiation exposure to staff. With the development of technology, remotely controlled afterloading devices were introduced, which in addition to complying with the above requirement, allow the source to move in different positions along catheters housed in one or more channels, making therapeutic brachytherapy treatments in tumor volumes possible, that due to its length, decades ago would have been an unthinkable deal. In all cases, sources, which may vary from the 3 mm in length, 125 Iodine or 198 Gold seeds, to extensive wires of 192 Iridium, are encapsulated for two main purposes: preventing leakage of radioactive material and absorption of unwanted radiation, alpha and beta, produced by the radioactive decay. Consequently, it should be highly unlikely that the radioactive material, could be lost or located in the patient, in a different place of the one that was planned. However, history shows us the opposite. Its is known the kind of deterministic effect that radiation is going to produce in the tumor, where the severity of

  18. High-resolution 3D dose distribution measured for two low-energy x-ray brachytherapy seeds: 125I and 103Pd

    International Nuclear Information System (INIS)

    Massillon-JL, G.; Minniti, R.; Mitch, M.G.; Soares, C.G.; Hearn, R.A.

    2011-01-01

    In this work, we have investigated the 3D absorbed dose distribution around 125 I and 103 Pd low-energy photon brachytherapy seeds using a high-spatial-resolution gel scanning system to address the current difficulty in measuring absorbed dose at close distances to these sources as a consequence of high dose rate gradient. A new version of BANG-gel coupled with a small format laser CT scanner has been used. Measurements were performed with 100 μm resolution in all dimensions. In particular, radial dose function and absorbed dose rate in the plane parallel to the sources longitudinal-axis were derived at radial distances smaller than or equal to 1 cm. In addition, the energy dependence was evaluated, finding that, within measurement uncertainties, the gel response is independent of the energy for energy photon values between 20 keV and 1250 keV. We have observed that at distances larger than 1.4 mm from the source, the delivered dose is similar to predictions from published Monte Carlo calculations (MC) for the 125 I seed. For distances between 1 mm and 3 mm, differences in magnitude and shape are significant for the 103 Pd seed, where an enhancement is observed. In the enhancement region, a difference of up to 70% in the radial dose function was obtained. Such observation suggests a contribution from other radionuclides emitting beta-particles or electrons, and not considered by MC. To understand the effect, spectrometry measurements were performed. A small contribution of 102 Rh/ 102m Rh radionuclide relative to 103 Pd was observed and its importance on the absorbed dose measured at close distances to the seed is time dependent and consequently, avoids reproducible measurements. Finally, the results obtained in this work underscore the importance of using high-spatial-resolution and water-equivalent detectors for measuring absorbed dose in low-energy photon radiation fields.

  19. Radio-iodination of plasma membranes of toad bladder epithelium

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, H J; Edelman, I S [California Univ., San Francisco (USA). Cardiovascular Research Inst.; California Univ., San Francisco (USA). Dept. of Medicine; California Univ., San Francisco (USA). Dept. of Biochemistry and Biophysics)

    1979-01-01

    The present report describes high yield enzymatic radio-iodination of the apical and basal-lateral plasma membranes of toad bladder epithelium with /sup 125/I-Na, by a procedure that does not breach the functional integrity of the epithelium, as assessed by the basal and vasopressin-sensitive short-circuit current (SCC). Iodination of basal-lateral plasma membranes, at a yield comparable to that obtained with apical labelling, was attained after about 30 min of exposure of the intact bladder to the labelling solutions. Approximately 25% of the basal-lateral labeling was lost when the epithelial cells were harvested after collagenase treatment, implying that some iodination of the basement membrane had taken place. Less than 10% of iodination of the apical or basal-lateral surfaces was accounted for by lipid-labeling. Analysis of the labeled apical and basal-lateral species by enzymatic digestion and thin layer chromatography disclosed that virtually all the radioactivity was present as mono-iodotyrosine (MIT). (orig./AJ).

  20. The incorporation of specific tissue/nuclide attenuation data into the Anderson method for producing brachytherapy volume-dose histograms

    International Nuclear Information System (INIS)

    Loft, S.M.; Dale, R.G.

    1990-01-01

    Anderson (1986) has proposed an analytical method for deriving volume-dose histograms relating to three-dimensional brachytherapy distributions. Because the mathematical transformation allows the otherwise dominant effects of the inverse-square fall-off about individual sources to be effectively suppressed, resulting histograms provide the potential for visually and numerically assessing overall quality of a brachytherapy treatment. In this paper the Anderson equations have been combined with the radial-dose polynomials of Dale, which are applicable to a number of tissue/nuclide combinations, and the predictions of the combined formalism used to further investigate the physical aspects of brachytherapy dosimetry. The problems associated with the dosimetry of low-energy γ-emitters such as 125 I are once again highlighted, as are potential advantages of using a radionuclide with an intermediate γ-ray energy. (author)

  1. Preparation of a 125I labeled derivative of penicillin to be used for radioimmunoassay

    International Nuclear Information System (INIS)

    Wal, J.-M.; Kann, Guy; Centre National de Recherches Zootechniques

    1975-01-01

    A 125 I-BSA Penicilloyl conjugate was prepared by coupling penicillin G to Bovine Serum Albumine previously labeled with iodine-125. The reaction of fixation by covalent binding was made in alkaline solution without the use of carbodiimide. Immunoreactivity and specific activity of this labeled conjugate enable radioimmunoassay of penicilloyl groups [fr

  2. Radiochromic film calibration for low-energy seed brachytherapy dose measurement

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Hali, E-mail: hamorris@ualberta.ca; Menon, Geetha; Sloboda, Ron S. [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada)

    2014-07-15

    Purpose: Radiochromic film dosimetry is typically performed for high energy photons and moderate doses characterizing external beam radiotherapy (XRT). The purpose of this study was to investigate the accuracy of previously established film calibration procedures used in XRT when applied to low-energy, seed-based brachytherapy at higher doses, and to determine necessary modifications to achieve similar accuracy in absolute dose measurements. Methods: Gafchromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 75 kVp, 200 kVp, 6 MV, and (∼28 keV) I-125 photon sources. For the latter irradiations a custom phantom was built to hold a single I-125 seed. Film pieces were scanned with an Epson 10000XL flatbed scanner and the resulting 48-bit RGB TIFF images were analyzed using both FilmQA Pro software andMATLAB. Calibration curves relating dose and optical density via a rational functional form for all three color channels at each irradiation energy were determined with and without the inclusion of uncertainties in the measured optical densities and dose values. The accuracy of calibration curve variations obtained using piecewise fitting, a reduced film measurement area for I-125 irradiation, and a reduced number of dose levels was also investigated. The energy dependence of the film lot used was also analyzed by calculating normalized optical density values. Results: Slight differences were found in the resulting calibration curves for the various fitting methods used. The accuracy of the calibration curves was found to improve at low doses and worsen at high doses when including uncertainties in optical densities and doses, which may better represent the variability that could be seen in film optical density measurements. When exposing the films to doses > 8 Gy, two-segment piecewise fitting was found to be necessary to achieve similar accuracies in absolute dose measurements as when using smaller dose ranges. When reducing the film measurement

  3. Radio-iodine in thyroid glands of swans, farm animals and humans, also in algae and river water from the Thames Valley, England

    Energy Technology Data Exchange (ETDEWEB)

    Howe, J.R.; Lloyd, M.K.

    1986-01-01

    A highly sensitive counting system has been used to measure radio-iodine in environmental samples from the Thames Valley. Iodine-125 and occasionally iodine-131 have been found in the thyroid glands of most of the swans that have died on the River Thames, the River Wey and the Grand Union Canal, and in algae and water samples from the Thames and many of its tributaries. The presence of this activity is ascribed to the waste discarded into the drainage system by hospitals and research laboratories, reaching the rivers via the effluent from sewage treatment works. The Thames is used as a source of drinking water, particularly in London and its western approaches. Weed and water samples collected from river water abstraction points, reservoirs, tap water supplies, and animal water troughs fed from this supply all contained low levels of iodine-125. The drinking water route can account for the iodine-125 found in the thyroids of farm animals from west Surrey and in a few people living in London. The amounts found constitute a trivial radiation dose to man and animals as they are far below the acceptable limit of exposure for man.

  4. Arterial double-contrast dual-energy MDCT: in-vivo rabbit atherosclerosis with iodinated nanoparticles and gadolinium agents

    Science.gov (United States)

    Carmi, Raz; Kafri, Galit; Altman, Ami; Goshen, Liran; Planer, David; Sosna, Jacob

    2010-03-01

    An in-vivo feasibility study of potentially improved atherosclerosis CT imaging is presented. By administration of two different contrast agents to rabbits with induced atherosclerotic plaques we aim at identifying both soft plaque and vessel lumen simultaneously. Initial injection of iodinated nanoparticle (INP) contrast agent (N1177 - Nanoscan Imaging), two to four hours before scan, leads to its later accumulation in macrophage-rich soft plaque, while a second gadolinium contrast agent (Magnevist) injected immediately prior to the scan blends with the aortic blood. The distinction between the two agents in a single scan is achieved with a double-layer dual-energy MDCT (Philips Healthcare) following material separation analysis using the reconstructed images of the different x-ray spectra. A single contrast agent injection scan, where only INP was injected two hours prior to the scan, was compared to a double-contrast scan taken four hours after INP injection and immediately after gadolinium injection. On the single contrast agent scan we observed along the aorta walls, localized iodine accumulation which can point on INP uptake by atherosclerotic plaque. In the double-contrast scan the gadolinium contributes a clearer depiction of the vessel lumen in addition to the lasting INP presence. The material separation shows a good correlation to the pathologies inferred from the conventional CT images of the two different scans while performing only a single scan prevents miss-registration problems and reduces radiation dose. These results suggest that a double-contrast dual-energy CT may be used for advanced clinical diagnostic applications.

  5. The American Brachytherapy Society recommendations for low-dose-rate brachytherapy for carcinoma of the cervix

    International Nuclear Information System (INIS)

    Nag, Subir; Chao, Clifford; Erickson, Beth; Fowler, Jeffery; Gupta, Nilendu; Martinez, Alvaro; Thomadsen, Bruce

    2002-01-01

    Purpose: This report presents guidelines for using low-dose-rate (LDR) brachytherapy in the management of patients with cervical cancer. Methods: Members of the American Brachytherapy Society (ABS) with expertise in LDR brachytherapy for cervical cancer performed a literature review, supplemented by their clinical experience, to formulate guidelines for LDR brachytherapy of cervical cancer. Results: The ABS strongly recommends that radiation treatment for cervical carcinoma (with or without chemotherapy) should include brachytherapy as a component. Precise applicator placement is essential for improved local control and reduced morbidity. The outcome of brachytherapy depends, in part, on the skill of the brachytherapist. Doses given by external beam radiotherapy and brachytherapy depend upon the initial volume of disease, the ability to displace the bladder and rectum, the degree of tumor regression during pelvic irradiation, and institutional practice. The ABS recognizes that intracavitary brachytherapy is the standard technique for brachytherapy for cervical carcinoma. Interstitial brachytherapy should be considered for patients with disease that cannot be optimally encompassed by intracavitary brachytherapy. The ABS recommends completion of treatment within 8 weeks, when possible. Prolonging total treatment duration can adversely affect local control and survival. Recommendations are made for definitive and postoperative therapy after hysterectomy. Although recognizing that many efficacious LDR dose schedules exist, the ABS presents suggested dose and fractionation schemes for combining external beam radiotherapy with LDR brachytherapy for each stage of disease. The dose prescription point (point A) is defined for intracavitary insertions. Dose rates of 0.50 to 0.65 Gy/h are suggested for intracavitary brachytherapy. Dose rates of 0.50 to 0.70 Gy/h to the periphery of the implant are suggested for interstitial implant. Use of differential source activity or

  6. Site of iodination in hyperplastic thyroid glands deduced from autoradiographs

    International Nuclear Information System (INIS)

    Wollman, S.H.; Ekholm, R.

    1981-01-01

    We have tried to ascertain the site of iodination in the chronically stimulated, hyperplastic thyroid gland of rats. Rats were fed propylthiouracil in a commercial rat diet for 10 days. Then the diet was changed to a low iodine diet for 5 days. To label the gland, 10 mCi of 125I-iodide was injected into the left heart ventricle. Ten seconds later the animal was perfused through the left ventricle with a fixative solution containing a goitrogen to block further iodination, and stable iodide to help extract uncombined radioiodide. Electron microscopic autoradiographs prepared from the fixed thyroids show strong labeling over the lumen of the follicle and no consistent labeling of any other site or organelle. We conclude that the site of iodination in the chronically stimulated, hyperplastic thyroid is the follicular lumen, i.e. the same as that in the normal gland

  7. Therapeutic value of 3-D printing template-assisted 125I-seed implantation in the treatment of malignant liver tumors

    Directory of Open Access Journals (Sweden)

    Han T

    2017-07-01

    Full Text Available Tao Han,1,* Xiaodan Yang,1,* Ying Xu,2,* Zhendong Zheng,1,* Ying Yan,2 Ning Wang2 1Department of Oncology, 2Department of Radiotherapy, General Hospital of Shenyang Military Region, Shenyang, China *These authors contributed equally to this work Objective: To explore the therapeutic value of 3-D printing template-assisted 125I-seed implantation in the treatment of malignant liver tumors.Materials and methods: Fifteen liver cancer patients with 47 total lesions were treated with 3-D printing template-assisted radioactive seed implantation (group A, and 25 liver-tumor patients with 66 total lesions were treated with 125I-seed implantation without a template auxiliary (group B. Operation time, in-hospital time, operation complications, dose distribution, and response rate (number were compared between the two groups. Results: Shorter operation times and better dose distribution were observed in group A than in group B, and the differences were statistically significant. The response rate after 2 months was 86.7% (13 of 15 in group A and 84% (21 of 25 in group B; differences between the two groups were not significant.Conclusion: Application of 3-D printing template-assisted radioactive seed implantation in the treatment of malignant liver tumors can help shorten operation time and optimize radiation-dose distribution, is worthy of further study, and has clinical significance. Keywords: brachytherapy, stereotactic techniques, iodine isotopes, liver, carcinoma 

  8. The radiotoxicology of iodine

    International Nuclear Information System (INIS)

    Taylor, D.M.

    1981-01-01

    Thirty radioisotopes of iodine are known but only those with mass numbers from 123 to 135 are of major radiotoxicological interest. Exposure of animals or man to inorganic 131 I or 125 I may result in the induction of benign or malignant thyroid tumors or depression of thyroid function; Bq for Bq 125 I is less toxic than 131 I. However, the shorter lived radioiodines 132 I, 133 I, and 135 I appear to be 10 to 100 times more toxic than 131 I alone. Little information is available about the toxicity of radioiodine containing organic compounds. The DNA precursor, iododeoxyuridine when labelled with 125 I becomes incorporated into the cell nucleus and produces severe and often irreparable damage due to the emission of Auger electrons. The risk estimate for the induction of thyroid carcinoma or adenoma by inorganic 131 I is considered to be 10 to 20x10 -6 persons Gy -1 y -1 , but may be up to 100 times larger for persons exposed to mixtures of short-lived radioiodines. (author)

  9. Study on labelling methods of 125I-RC-160 and its biodistribution in animals

    International Nuclear Information System (INIS)

    Wang Jing; Wang Xiqing; Wang Liangang; Li Fujun; Deng Jinglan

    2002-01-01

    A method for the iodination of peptide RC-160 with high efficiency was developed. RC-160 was iodinated with N-bromosuccinimide (NBS) as oxidant, the conventional chloramine T (Ch-T) method was used as control. The labelling condition of NBS method was optimized and radiolabelled conjugate 125 I-RC-160 was assessed as follows: no further purification was needed, the measured labelling yield of 125 I-RC-160 was 92% and the specific activity was 1.95 x 10 12 Bq/m mol. The yield increased as the amount of NBS increased. The optimal ratio of RC-160 (μg): 125 I (MBq): NBS(μg) was 3:7.4:1. For Ch-T method, the labelling yield is 56% and specific activity was 0.65 x 10 12 Bq/m mol; but after purification by SepPak-C 18 , the labelling yield may reach as high as 92%. 1h after injection, radioactivity in blood decreased by 87.2%. No obvious concentration of 125 I-RC-160 in thyroid or kidney was observed

  10. Photon energy-fluence correction factor in low energy brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Antunes, Paula C.G.; Yoriyaz, Hélio [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Vijande, Javier; Giménez-Alventosa, Vicent; Ballester, Facundo, E-mail: pacrisguian@gmail.com [Department of Atomic, Molecular, and Nuclear Physics and Instituto de Física Corpuscular (UV-CSIC), University of Valencia (Spain)

    2017-07-01

    The AAPM TG-43 brachytherapy dosimetry formalism has become a standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed dose to water at different locations. At the time of relating dose to tissue and dose to water, or vice versa, it is usually assumed that the photon fluence in water and in tissues are practically identical, so that the absorbed dose in the two media can be related by their ratio of mass energy-absorption coefficients. The purpose of this work is to study the influence of photon energy-fluence in different media and to evaluate a proposal for energy-fluence correction factors for the conversion between dose-to-tissue (D{sub tis}) and dose-to-water (D{sub w}). State-of-the art Monte Carlo (MC) calculations are used to score photon fluence differential in energy in water and in various human tissues (muscle, adipose and bone) in two different codes, MCNP and PENELOPE, which in all cases include a realistic modeling of the {sup 125}I low-energy brachytherapy seed in order to benchmark the formalism proposed. A correction is introduced that is based on the ratio of the water-to-tissue photon energy-fluences using the large-cavity theory. In this work, an efficient way to correlate absorbed dose to water and absorbed dose to tissue in brachytherapy calculations at clinically relevant distances for low-energy photon emitting seed is proposed. The energy-fluence based corrections given in this work are able to correlate absorbed dose to tissue and absorbed dose to water with an accuracy better than 0.5% in the most critical cases. (author)

  11. Photon energy-fluence correction factor in low energy brachytherapy

    International Nuclear Information System (INIS)

    Antunes, Paula C.G.; Yoriyaz, Hélio; Vijande, Javier; Giménez-Alventosa, Vicent; Ballester, Facundo

    2017-01-01

    The AAPM TG-43 brachytherapy dosimetry formalism has become a standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed dose to water at different locations. At the time of relating dose to tissue and dose to water, or vice versa, it is usually assumed that the photon fluence in water and in tissues are practically identical, so that the absorbed dose in the two media can be related by their ratio of mass energy-absorption coefficients. The purpose of this work is to study the influence of photon energy-fluence in different media and to evaluate a proposal for energy-fluence correction factors for the conversion between dose-to-tissue (D tis ) and dose-to-water (D w ). State-of-the art Monte Carlo (MC) calculations are used to score photon fluence differential in energy in water and in various human tissues (muscle, adipose and bone) in two different codes, MCNP and PENELOPE, which in all cases include a realistic modeling of the 125 I low-energy brachytherapy seed in order to benchmark the formalism proposed. A correction is introduced that is based on the ratio of the water-to-tissue photon energy-fluences using the large-cavity theory. In this work, an efficient way to correlate absorbed dose to water and absorbed dose to tissue in brachytherapy calculations at clinically relevant distances for low-energy photon emitting seed is proposed. The energy-fluence based corrections given in this work are able to correlate absorbed dose to tissue and absorbed dose to water with an accuracy better than 0.5% in the most critical cases. (author)

  12. A comparative study on the iodine-labeled methods of protein and polypeptide

    Energy Technology Data Exchange (ETDEWEB)

    Huaifen, Li; Huisheng, Niu; Mingyue, Yuan; Jinghua, Yu [Chinese Academy of Medical Sciences, Tianjin (China). Inst. of Radiation Medicine

    1994-02-01

    There are three methods: chloramine-T, Iodogen and lactoperoxidase(LPO). [sup 125]I-ACTH, [sup 125]I-insulin and [sup 125]I-HSA are prepared by these techniques. The results show that lactoperoxidase is isolated and purified from fresh milk, meanwhile, the enzyme is used in experiments of [sup 125]I-labeled protein, peptide hormone and mono-clone antibody, etc. LPO is a very successful method for it's mild, complete reaction, controllable, high labelling yield, higher purity of iodine-labeled compound and so on. It remains biological activation and stable character more than other two techniques.

  13. Results of a dummy run of postimplant dosimetry between multi-institutional centers in prostate brachytherapy with 125I seeds

    International Nuclear Information System (INIS)

    Aoki, Manabu; Yorozu, Atsunori; Dokiya, Takushi

    2009-01-01

    The purpose of this study was to determine the reproducibility and precision of postimplant dosimetry following 125 I prostate brachytherapy (PB) and to evaluate the effects of learning and experience in CT-based postimplant dosimetry. One-month postimplant CT data from two patients who underwent PB alone or combined therapy (PB+external beam radiation therapy (EBRT)) were sent to 28 institutions for postimplant dosimetry and analyzed in 2006 (study 1). Similarly, 1-month postimplant CT data from two other patients were also analyzed in 2008 (study 2; 23 institutions). For both modalities in studies 1 and 2, the variance of the difference between CT-based D90 at each institution and CT/MRI fusion-based D90 was estimated. In monotherapy, F test and Mann-Whitney U test revealed no significant difference in the variance in studies 1 and 2 (P=0.72, 0.46). In combined therapy, the variance significantly converged in study 2 compared with study 1 (P<0.05). Even in the two studies, however, the difference between the median CT-based D90 and fusion-based D90 was at least 20-30 Gy. Marked interobserver variability was seen in the prostate volume and D90 with CT alone. The precision of postimplant dosimetry based on CT alone was revealed to be limited. (author)

  14. Production of high quality sodium iodide preparations labelled with carrier free iodine-125

    International Nuclear Information System (INIS)

    Abdukayumov, M.N.; Chistyakov, P.G.; Shilin, E.A.

    2001-01-01

    Work is related to the problem of high-quality Sodium Iodide preparation production and to the choice of the peptids iodination methods with the purpose of control test developing to determine the Biological activity of the above mentioned preparation

  15. The use of 125iodine-labeled RNA for detection of the RNA binding to ribosomes

    International Nuclear Information System (INIS)

    Mori, Tomohiko; Fukuda, Mitsuru

    1975-01-01

    The in vitro labeling of RNA with radioactive iodine is the efficient method to obtain the RNA with high specific activity. The present paper reports on the application of this technique to the production of iodine-labeled RNA for use in the experiment of binding RNA to ribosomes. Tobacco mosaic virus (TMV) RNA was used as natural mRNA, and E. coli S-30 preparation was used as a source of ribosomes. The TMV-RNA was prepared by bentonite-phenol extraction from TMV, and the method used for the iodation of RNA was based on the procedure described by Getz et al. The iodine-labeled RNA was incubated in a cell-free protein synthesizing system (S-30) prepared from E. coli K-12. After the incubation, the reaction mixture was layered onto sucrose gradient, centrifuged, and fractionated into 18 fractions. Optical density at 260 nm was measured, and radioactivity was counted, for each fraction. The binding of mRNA to ribosomes occurred even at 0 deg C, and the occurrence of the nonspecific binding was also shown. Consequently, the specific binding, i.e. the formation of the initiation complex being involved in amino acid incorporation, may be estimated by subtracting the radioactivity associated with monosomes in the presence of both rRNA and ATA from that in the presence of rRNA only. It was shown that the iodine-labeled RNA can be used for the studies of binding RNA to ribosomes. (Kako, I.)

  16. Long-Term Results of an RTOG Phase II Trial (00-19) of External-Beam Radiation Therapy Combined With Permanent Source Brachytherapy for Intermediate-Risk Clinically Localized Adenocarcinoma of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Lawton, Colleen A., E-mail: clawton@mcw.edu [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States); Yan, Yan [Radiation Therapy Oncology Group Statistical Center, Philadelphia, PA (United States); Lee, W. Robert [Department of Radiation Oncology, Duke University School of Medicine, Durham, NC (United States); Gillin, Michael [Department of Radiation Oncology, MD Anderson Cancer Center, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Firat, Selim [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States); Baikadi, Madhava [Department of Radiation Oncology, Northeast Radiation Oncology Center, Scranton, PA (United States); Crook, Juanita [Department of Radiation Oncology, University of British Columbia, Kelowna, BC (Canada); Kuettel, Michael [Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, NY (United States); Morton, Gerald [Department of Radiation Oncology, Toronto-Sunnybrook Regional Cancer Center, Toronto, ON (Canada); Sandler, Howard [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, CA (United States)

    2012-04-01

    Purpose: External-beam radiation therapy combined with low-doserate permanent brachytherapy are commonly used to treat men with localized prostate cancer. This Phase II trial was performed to document late gastrointestinal or genitourinary toxicity as well as biochemical control for this treatment in a multi-institutional cooperative group setting. This report defines the long-term results of this trial. Methods and Materials: All eligible patients received external-beam radiation (45 Gy in 25 fractions) followed 2-6 weeks later by a permanent iodine 125 implant of 108 Gy. Late toxicity was defined by the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer late radiation morbidity scoring scheme. Biochemical control was defined by the American Society for Therapeutic Radiology and Oncology (ASTRO) Consensus definition and the ASTRO Phoenix definition. Results: One hundred thirty-eight patients were enrolled from 20 institutions, and 131 were eligible. Median follow-up (living patients) was 8.2 years (range, 2.7-9.3 years). The 8-year estimate of late grade >3 genitourinary and/or gastrointestinal toxicity was 15%. The most common grade >3 toxicities were urinary frequency, dysuria, and proctitis. There were two grade 4 toxicities, both bladder necrosis, and no grade 5 toxicities. In addition, 42% of patients complained of grade 3 impotence (no erections) at 8 years. The 8-year estimate of biochemical failure was 18% and 21% by the Phoenix and ASTRO consensus definitions, respectively. Conclusion: Biochemical control for this treatment seems durable with 8 years of follow-up and is similar to high-dose external beam radiation alone or brachytherapy alone. Late toxicity in this multi-institutional trial is higher than reports from similar cohorts of patients treated with high-dose external-beam radiation alone or permanent low-doserate brachytherapy alone, perhaps suggesting further attention to strategies that limit doses to

  17. Monte Carlo simulation for treatment planning optimization of the COMS and USC eye plaques using the MCNP4C code

    International Nuclear Information System (INIS)

    Jannati Isfahani, A.; Shokrani, P.; Raisali, Gh.

    2010-01-01

    Ophthalmic plaque radiotherapy using I-125 radioactive seeds in removable episcleral plaques is often used in management of ophthalmic tumors. Radioactive seeds are fixed in a gold bowl-shaped plaque and the plaque is sutured to the scleral surface corresponding to the base of the intraocular tumor. This treatment allows for a localized radiation dose delivery to the tumor with a minimum target dose of 85 Gy. The goal of this study was to develop a Monte Carlo simulation method for treatment planning optimization of the COMS and USC eye plaques. Material and Methods: The MCNP4C code was used to simulate three plaques: COMS-12mm, COMS-20mm, and USC ≠9 with I-125 seeds. Calculation of dose was performed in a spherical water phantom (radius 12 mm) using a 3D matrix with a size of 12 voxels in each dimension. Each voxel contained a sphere of radius 1 mm. Results: Dose profiles were calculated for each plaque. Isodose lines were created in 2 planes normal to the axes of the plaque, at the base of the tumor and at the level of the 85 Gy isodose in a 7 day treatment. Discussion and Conclusion: This study shows that it is necessary to consider the following tumor properties in design or selection of an eye plaque: the diameter of tumor base, its thickness and geometric shape, and the tumor location with respect to normal critical structures. The plaque diameter is selected by considering the tumor diameter. Tumor thickness is considered when selecting the seed parameters such as their number, activity and distribution. Finally, tumor shape and its location control the design of following parameters: the shape and material of the plaque and the need for collimation.

  18. Isotope selection for patients undergoing prostate brachytherapy

    International Nuclear Information System (INIS)

    Cha, Christine M.; Potters, Louis; Ashley, Richard; Freeman, Katherine; Wang Xiaohong; Waldbaum, Robert; Leibel, Steven

    1999-01-01

    Purpose: Ultrasound-guided trans perineal interstitial permanent prostate brachytherapy (TIPPB) is generally performed with either 103 Pd or 125 I. The use of 125 I for low Gleason score tumors and 103 Pd for higher Gleason scores has been suggested based on isotope dose rate and cell doubling time observed in in vitro studies. While many centers follow these isotope selection criteria, other centers have elected to use only a single isotope, regardless of Gleason score. No clinical data have been published comparing these isotopes. This study was undertaken to compare outcomes between 125 I and 103 Pd in a matched pair analysis for patients undergoing prostate brachytherapy. Methods and Materials: Six hundred forty-eight consecutively treated patients with clinically confined prostate cancer underwent TIPPB between June 1992 and February 1997. Five hundred thirty-two patients underwent TIPPB alone, whereas 116 received pelvic external beam irradiation and TIPPB. Ninety-three patients received androgen deprivation therapy prior to TIPPB. The prescribed doses for TIPPB were 160 Gy for 125 I (pre-TG43) and 120 Gy for 103 Pd. Patients treated with combination therapy received 41.4 or 45 Gy (1.8 Gy/fraction) external beam irradiation followed by a 3- to 5-week break and then received either a 120-Gy 125 I or a 90-Gy 103 Pd implant. Until November 1994, all patients underwent an 125 I implant after which the isotope selection was based on either Gleason score (Gleason score 2-5: 125 I; Gleason 5-8: 103 Pd) or isotope availability. A matched pair analysis was performed to assess any difference between isotopes. Two hundred twenty-two patients were matched according to Gleason score, prostate-specific antigen (PSA), and stage. PSA relapse-free survival (PSA-RFS) was calculated based on the American Society for Therapeutic Radiology and Oncology (ASTRO) Consensus Group definition of failure. Kaplan-Meier actuarial survival curves were compared to assess differences in

  19. 125I radioimmunoassay for primary conjugated bile salts

    International Nuclear Information System (INIS)

    Spenney, J.G.; Johnson, B.J.; Hirschowitz, B.I.; Mihas, A.A.; Gibson, R.

    1977-01-01

    Cholylglycylhistamine, a derivative of cholic acid, has been synthesized and characterized. This derivative has been iodinated using Na125I and chloramine-T and purified free from unlabeled cholylglycylhistamine. Application of this iodinated bile salt derivative to radioimmunoassay of bile salts in human serum is reported. Antibody titers have uniformly increased over titers used in tritium-based assays; some antibodies are usable in dilutions of 1 : 80,000. The radioimmunoassay described here was found to measure predominantly the primary conjugated bile salts. Sensitivity has been maintained, with the least detectable amount being 0.5 pmoles per assay tube. Normal values in human serum are 3.47 +- 2.16 (SD) nmoles per ml

  20. A comparison of radiation dose to the neurovascular bundles in men with and without prostate brachytherapy-induced erectile dysfunction

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Dorsey, Anthony T.; Lief, Jonathan H.; Donzella, Joseph G.

    2000-01-01

    Purpose: The etiology of erectile dysfunction after definitive local therapy for carcinoma of the prostate gland represents a multifactorial phenomenon including neurogenic compromise, venous insufficiency, local trauma, and psychogenic causes. It has been suggested that impotence after prostate brachytherapy is a consequence of excessive radiation dose to the neurovascular bundles (NVB). Herein we evaluate the potential relationship between radiation dose to the NVB and the development of erectile dysfunction following prostate brachytherapy. Methods and Materials: The radiation dose to the NVB was evaluated for 33 patients who developed erectile dysfunction (ED) following brachytherapy plus 21 additional patients who were potent before and subsequent to brachytherapy. Of the 54 patient study group, the median follow up was 37 months, and 25 patients were managed with 125 I as a monotherapeutic approach and 29 received 103 Pd as a boost following 45 Gy of external beam radiation therapy. Radiographic localization of the NVB was performed via a two-dimensional geometric model that placed 3-NVB calculation points on the left and right posterolateral side of each 5-mm CT slice. Parameters evaluated included dose-surface histograms, dose parameters via point doses on each slice, the magnitude of the dose in relationship to the distance from the base, and the relationship between NVB radiation dose in patients with and without ED, patient response to sildenafil and case sequence number. Results: In terms of percent prescribed minimum peripheral dose (% mPD), there was no significant difference in mean neurovascular bundle dose between potent and impotent patients, between the isotopes ( 125 I or 103 Pd), mono- or boost therapy, or side of the prostate for which the overall average was 217% ± 55% of mPD. There was also no significant dosimetric difference in terms of response to sildenafil based on a multivariate analysis which included % mPD and various dose

  1. Improved removal of iodine-125 from effluents by the soil column method using a laterite soil

    Energy Technology Data Exchange (ETDEWEB)

    Sakuma, S H [Malaysian Inst. for Nuclear Technology Research, Bangi, Selangor (Malaysia)

    1997-02-01

    The soil column experiments were conducted to treat the liquid wastes from hospitals containing {sup 125}I. Three sorbent samples of laterite clay materials with different content of iron oxides (geothite, {alpha}-FeOOH) and hydroxides were used to sorb anionic iodate. Post-treatment of the liquid wastes with sodium hypochlorite (redox reagent) oxidized the iodide to the desirable iodate ion. pH after treatment ranges between 4.8 to 5.8 that is not very much different from the initial value pH4.5. The results show that 90 to 97% sorption of iodine with the decontamination factor between 10-32 could be obtained after the first two hours of experiments. The concentration has decreased from an initial value of 10 Bq{center_dot}mL{sup -1} to the concentration ranges 0.3 to 0.9 Bq{center_dot}mL{sup -1}. For the soil at pH between 4.5 to 6.0, positive charges predominated on the kaolinite, geothite and aluminum hydroxides. The negative {sup 125}I anions were electrostatically held by the positive charges on the mineral components of the laterite clay materials. The treated effluents could be released to the environment safely after further dilution and decay. The storage period will decrease tremendously providing better management for the disposal of the wastes by generators. The batch experiments conducted using different sorbent masses of soils, show that there was a drop in sorption where the mass of soils falls below approximately between 0 to 0.25 g. The sorption remains constant with the soil mass above 0.25 g. Another batch experiment using different concentration, shows that adsorption capacity of the laterite soil was 1.1 {mu}Ci/g. The adsorption is about 96% with a distribution coefficient of 1170. The experiments conducted show that anionic iodate in the liquid wastes can be removed by the laterite soil material. The column treatment method was more effective, easy to handle, and has low a capital and maintenance cost. (author). 9 refs, 10 figs, 2 tabs.

  2. Evaluating the Phoenix definition of biochemical failure after (125)I prostate brachytherapy: Can PSA kinetics distinguish PSA failures from PSA bounces?

    Science.gov (United States)

    Thompson, Anna; Keyes, Mira; Pickles, Tom; Palma, David; Moravan, Veronika; Spadinger, Ingrid; Lapointe, Vincent; Morris, W James

    2010-10-01

    To evaluate the prostate-specific antigen (PSA) kinetics of PSA failure (PSAf) and PSA bounce (PSAb) after permanent (125)I prostate brachytherapy (PB). The study included 1,006 consecutive low and "low tier" intermediate-risk patients treated with (125)I PB, with a potential minimum follow-up of 4 years. Patients who met the Phoenix definition of biochemical failure (nadir + 2 ng/mL(-1)) were identified. If the PSA subsequently fell to ≤0.5 ng/mL(-1)without intervention, this was considered a PSAb. All others were scored as true PSAf. Patient, tumor and dosimetric characteristics were compared between groups using the chi-square test and analysis of variance to evaluate factors associated with PSAf or PSAb. Median follow-up was 54 months. Of the 1,006 men, 57 patients triggered the Phoenix definition of PSA failure, 32 (56%) were true PSAf, and 25 PSAb (44%). The median time to trigger nadir + 2 was 20.6 months (range, 6-36) vs. 49 mo (range, 12-83) for PSAb vs. PSAf groups (p < 0.001). The PSAb patients were significantly younger (p < 0.0001), had shorter time to reach the nadir (median 6 vs. 11.5 months, p = 0.001) and had a shorter PSA doubling time (p = 0.05). Men younger than age 70 who trigger nadir +2 PSA failure within 38 months of implant have an 80% likelihood of having PSAb and 20% chance of PSAf. With adequate follow-up, 44% of PSA failures by the Phoenix definition in our cohort were found to be benign PSA bounces. Our study reinforces the need for adequate follow-up when reporting PB PSA outcomes, to ensure accurate estimates of treatment efficacy and to avoid unnecessary secondary interventions. 2010. Published by Elsevier Inc. All rights reserved.

  3. Evaluating the Phoenix Definition of Biochemical Failure After 125I Prostate Brachytherapy: Can PSA Kinetics Distinguish PSA Failures From PSA Bounces?

    International Nuclear Information System (INIS)

    Thompson, Anna; Keyes, Mira; Pickles, Tom

    2010-01-01

    Purpose: To evaluate the prostate-specific antigen (PSA) kinetics of PSA failure (PSAf) and PSA bounce (PSAb) after permanent 125 I prostate brachytherapy (PB). Methods and Materials: The study included 1,006 consecutive low and 'low tier' intermediate-risk patients treated with 125 I PB, with a potential minimum follow-up of 4 years. Patients who met the Phoenix definition of biochemical failure (nadir + 2 ng/mL -1 ) were identified. If the PSA subsequently fell to ≤0.5 ng/mL -1 without intervention, this was considered a PSAb. All others were scored as true PSAf. Patient, tumor and dosimetric characteristics were compared between groups using the chi-square test and analysis of variance to evaluate factors associated with PSAf or PSAb. Results: Median follow-up was 54 months. Of the 1,006 men, 57 patients triggered the Phoenix definition of PSA failure, 32 (56%) were true PSAf, and 25 PSAb (44%). The median time to trigger nadir + 2 was 20.6 months (range, 6-36) vs. 49 mo (range, 12-83) for PSAb vs. PSAf groups (p < 0.001). The PSAb patients were significantly younger (p < 0.0001), had shorter time to reach the nadir (median 6 vs. 11.5 months, p = 0.001) and had a shorter PSA doubling time (p = 0.05). Men younger than age 70 who trigger nadir +2 PSA failure within 38 months of implant have an 80% likelihood of having PSAb and 20% chance of PSAf. Conclusions: With adequate follow-up, 44% of PSA failures by the Phoenix definition in our cohort were found to be benign PSA bounces. Our study reinforces the need for adequate follow-up when reporting PB PSA outcomes, to ensure accurate estimates of treatment efficacy and to avoid unnecessary secondary interventions.

  4. Labelling of human follicle stimulant hormone with 125I, for radioimmunoassay

    International Nuclear Information System (INIS)

    Pinto, H.; Werner, R.S.; Lerario, A.C.; Toledo e Souza, I.T. de; Wajchenberg, B.L.; Pieroni, R.R.

    1976-01-01

    An efficient labeling of human Follicle Stimulant Harmone is essential to development of sensitive radioimmunoassays. Iodination by Chloramine T method frequently is subject to severe iodination damage and some preparations are unaccetable for radioimmunoassays. Modifications to the Hunter method, changing incubation time, reaction temperature and reducing Chloramine T amount used in the reaction, were performed in obtaining a more effective labeling. FSH-125 I fraction obtained from Sephadex G-75 column purification presented excellent immunoreactivity and quality control of the steps of the reaction demonstrated a high percentage (90%) of intact Follicle Stimulant Hormone [pt

  5. Radioligand assays: methods and application. 5. /sup 125/I-monoidoinsulin: preparation, immunological and biological characterization

    Energy Technology Data Exchange (ETDEWEB)

    Besch, W; Woltanski, K P; Knospe, S; Ziegler, M; Keilacker, H [Zentralinstitut fuer Diabetes, Karlsburg (German Democratic Republic)

    1980-04-01

    A reproducible method for preparation of /sup 125/I-monoiodoinsulin with fully biological activity was developed. Monoiodoinsulin has been prepared from a heterogeneous /sup 125/I iodination mixture by anion exchange chromatography on DEAE-Sephadex A-25 without using any gradient elution technique. The specific radioactivity of /sup 125/I-monoiodoinsulin was calculated to 14.3 +- 0.8 TBq/g, i.e. an iodine content of 1.04 +- 0.06 atoms per molecule of insulin. Monoiodoinsulin was indistinguishable from native insulin with respect to binding to guinea pig anti-insulin serum, and to insulin receptors of isolated rat adipocytes. The biological potency (96.5 +- 7.5 per cent of the immunoreactive insulin activity) determined by the conversion of (/sup 14/C/sub 1/)-D-glucose to /sup 14/CO/sub 2/ in vitro by rat fat cells was not significantly different from that of native insulin.

  6. Radioimmunoassay of alpha-fetoprotein, with special reference to iodination and purification techniques

    International Nuclear Information System (INIS)

    Schiller, H.S.; Kulchinski, L.; Luthy, D.A.

    1978-01-01

    We report a relatively simple and convenient method for iodinating human alpha-fetoprotein and for purifying the 125 I-labeled material. The label is incorporated into human alpha-fetoprotein enzymatically by use of lactoperoxidase. Before each assay the labeled material is purified over two successive short columns: Sephacryl S-200 Superfine and cellulose. This procedure removes both free iodine and damaged fetoprotein. With the purified material we developed a sensitive and reliable radioimmunoassay for alpha-fetoprotein in serum and amniotic fluid

  7. Direct determination of the absorbed dose to water from 125I low dose-rate brachytherapy seeds using the new absorbed dose primary standard developed at ENEA-INMRI

    International Nuclear Information System (INIS)

    Toni, M.P.; Pimpinella, M.; Pinto, M.; Quini, M.; Cappadozzi, G.; Silvestri, C.; Bottauscio, O.

    2012-01-01

    Low-intensity radioactive sources emitting low-energy photons are used in the clinic for low dose-rate brachytherapy treatments of tumours. The dosimetry of these sources is based on reference air kerma rate measurements. The absorbed dose rate to water at the reference depth d 0 = 1 cm, D w , 1 cm, is then obtained by a conversion procedure with a large relative standard uncertainty of about 5%. This paper describes a primary standard developed at ENEA-INMRI to directly measure D w , 1 cm due to LDR sources. The standard is based on a large-angle and variable-volume ionization chamber, embedded in a graphite phantom and operating under 'wall-less air chamber' conditions. A set of correction and conversion factors, based on experiments and Monte Carlo simulations, are determined to obtain the value of D w , 1 cm from measurements of increment of ionization current with increasing chamber volume. The relative standard uncertainty on D w , 1 cm is 2.6%, which is appreciably lower than the current uncertainty. Characteristics of the standard, its associated uncertainty budget, and some experimental results are given for 125 I BEBIG I25.S16.C brachytherapy seeds. Finally, results of the experimental determination of the dose-rate constant 1 cm, traceable to the D w , 1 cm and the low-energy air kerma ENEA-INMRI standards, are given. The relative standard uncertainty on 1 cm is 2.9%, appreciably lower than the typical uncertainty (4.8%) of the values available in the literature. (authors)

  8. Flat choroidal melanoma masquerading as central serous chorioretinopathy

    Directory of Open Access Journals (Sweden)

    Timothy Patrick Higgins

    2016-01-01

    Full Text Available There are several mimickers of choroidal melanoma. We report a patient with recent family stress who developed blurred vision to 20/50 OD and was found to have unilateral central serous chorioretinopathy and a coincidental choroidal nevus. After 1 year without resolution of the subretinal fluid, the patient was referred for our opinion. On examination, visual acuity was 20/50 in the right eye and 20/20 in the left eye. The left eye was normal. Evaluation of the right eye showed a small, pigmented submacular choroidal lesion measuring 4 mm Χ 3 mm. Ultrasonography documented an isoechoic mass measuring 1.71 mm in thickness. Optical coherence tomography showed subretinal fluid with shaggy photoreceptors and hyper-reflective material within the subretinal fluid, likely indicative of lipofuscin within macrophages. Autofluorescence revealed orange pigment overlying the lesion. These features were strongly suggestive of small choroidal melanoma with five risk factors for tumor growth. Treatment with Iodine-125 plaque brachytherapy was performed on the patient. The readers should keep in mind that choroidal melanoma can manifest as a tiny choroidal mass with related multimodal imaging features of subretinal fluid and orange pigment.

  9. Studies in iodine metabolism: Progress report, July 1968-July 1969

    Energy Technology Data Exchange (ETDEWEB)

    Van Middlesworth, L.

    1987-01-01

    This document describes research on iodine metabolism conducted at the University of Tennessee, Memphis between July 1968 and July 1969. The author and his research team prepared autoradiographs of rat thyroids from individuals exposed to Iodine 125 in utero. Additional studies were conducted to determine the effect on hypothalamic lesions on iodide metabolism in rats; to evaluate an iodide-specific electrode for measuring iodide levels in blood or urine; and to study the amount of thyroxine absorption from the intestine. An analysis of bovine and sheep thyroids from eight locations provided additional information on global fallout levels. 21 figs., 2 tabs.

  10. Intravascular brachytherapy for peripheral vascular disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2008-09-01

    Full Text Available Scientific background: Percutaneous transluminal angioplasties (PTA through balloon dilatation with or without stenting, i.e. vessel expansion through balloons with or without of implantation of small tubes, called stents, are used in the treatment of peripheral artery occlusive disease (PAOD. The intravascular vessel irradiation, called intravascular brachytherapy, promises a reduction in the rate of repeated stenosis (rate of restenosis after PTA. Research questions: The evaluation addresses questions on medical efficacy, cost-effectiveness as well as ethic, social and legal implications in the use of brachytherapy in PAOD patients. Methods: A systematic literature search was conducted in August 2007 in the most important medical electronic databases for publications beginning from 2002. The medical evaluation included randomized controlled trials (RCT. The information synthesis was performed using meta-analysis. Health economic modeling was performed with clinical assumptions derived from the meta-analysis and economical assumptions derived from the German Diagnosis Related Groups (G-DRG-2007. Results: Medical evaluation: Twelve publications about seven RCT on brachytherapy vs. no brachytherapy were included in the medical evaluation. Two RCT showed a significant reduction in the rate of restenosis at six and/or twelve months for brachytherapy vs. no brachytherapy after successful balloon dilatation, the relative risk in the meta-analysis was 0.62 (95% CI: 0.46 to 0.84. At five years, time to recurrence of restenosis was significantly delayed after brachytherapy. One RCT showed a significant reduction in the rate of restenosis at six months for brachytherapy vs. no brachytherapy after PTA with optional stenting, the relative risk in the meta-analysis was 0.76 (95% CI: 0.61 to 0.95. One RCT observed a significantly higher rate of late thrombotic occlusions after brachytherapy in the subgroup of stented patients. A single RCT for brachytherapy

  11. Image Guided Cervical Brachytherapy: 2014 Survey of the American Brachytherapy Society

    Energy Technology Data Exchange (ETDEWEB)

    Grover, Surbhi, E-mail: Surbhi.grover@uphs.upenn.edu [Department of Radiation Oncology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Harkenrider, Matthew M. [Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Chicago, Illinois (United States); Cho, Linda P. [Department of Radiation Oncology, Brigham & Women' s Hospital/Dana-Farber Cancer Institute, Boston, Massachusetts (United States); Erickson, Beth [Department Radiation Oncology, Froedtert Hospital and Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Small, Christina [Department of Public Health Sciences, Stritch School of Medicine, Loyola University Chicago, Chicago, Illinois (United States); Small, William [Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Chicago, Illinois (United States); Viswanathan, Akila N. [Department of Radiation Oncology, Brigham & Women' s Hospital/Dana-Farber Cancer Institute, Boston, Massachusetts (United States)

    2016-03-01

    Purpose: To provide an update of the 2007 American brachytherapy survey on image-based brachytherapy, which showed that in the setting of treatment planning for gynecologic brachytherapy, although computed tomography (CT) was often used for treatment planning, most brachytherapists used point A for dose specification. Methods and Materials: A 45-question electronic survey on cervical cancer brachytherapy practice patterns was sent to all American Brachytherapy Society members and additional radiation oncologists and physicists based in the United States between January and September 2014. Responses from the 2007 survey and the present survey were compared using the χ{sup 2} test. Results: There were 370 respondents. Of those, only respondents, not in training, who treat more than 1 cervical cancer patient per year and practice in the United States, were included in the analysis (219). For dose specification to the target (cervix and tumor), 95% always use CT, and 34% always use MRI. However, 46% use point A only for dose specification to the target. There was a lot of variation in parameters used for dose evaluation of target volume and normal tissues. Compared with the 2007 survey, use of MRI has increased from 2% to 34% (P<.0001) for dose specification to the target. Use of volume-based dose delineation to the target has increased from 14% to 52% (P<.0001). Conclusion: Although use of image-based brachytherapy has increased in the United States since the 2007 survey, there is room for further growth, particularly with the use of MRI. This increase may be in part due to educational initiatives. However, there is still significant heterogeneity in brachytherapy practice in the United States, and future efforts should be geared toward standardizing treatment.

  12. Dosimetric study of the 15 mm ROPES eye plaque

    International Nuclear Information System (INIS)

    Granero, D.; Perez-Calatayud, J.; Ballester, F.; Casal, E.; Frutos, J.M. de

    2004-01-01

    The main aim of this paper is to make a study of dose-rate distributions obtained around the 15 mm, radiation oncology physics and engineering services, Australia (ROPES) eye plaque loaded with 125 I model 6711 radioactive seeds. In this study, we have carried out a comparison of the dose-rate distributions obtained by the algorithm used by the Plaque Simulator (PS) (BEBIG GmbH, Berlin, Germany) treatment planning system with those obtained by means of the Monte Carlo method for the ROPES eye plaque. A simple method to obtain the dose-rate distributions in a treatment planning system via the superposition of the dose-rate distributions of a seed placed in the eye plaque has been developed. The method uses eye plaque located in a simplified geometry of the head anatomy and distributions obtained by means of the Monte Carlo code GEANT4. The favorable results obtained in the development of this method suggest that it could be implemented on a treatment planning system to improve dose-rate calculations. We have also found that the dose-rate falls sharply along the eye and that outside the eye the dose-rate is very low. Furthermore, the lack of backscatter photons from the air located outside the eye-head phantom produces a dose reduction negligible for distances from the eye-plaque r<1 cm but reaches up to 20% near the air-eye interface. Results showed that the treatment planning system lacks accuracy around the border of the eye (in the sclera and the surrounding area) due to the simplicity of the algorithm used. The BEBIG treatment planning system uses a global attenuation factor that takes into account the effect of the eye plaque seed carrier and the lack of backscatter photons caused by the metallic cover, which in the case of a ROPES eye plaque has a default value of T=1 (no correction). In the present study, a global attenuation factor T=0.96 and an air-interface correction factor which improve on treatment planning system calculations were obtained

  13. Computational system to create an entry file for replicating I-125 seeds simulating brachytherapy case studies using the MCNPX code

    Directory of Open Access Journals (Sweden)

    Leonardo da Silva Boia

    2014-03-01

    decline for short distances.------------------------------Cite this article as: Boia LS, Junior J, Menezes AF, Silva AX. Computational system to create an entry file for replicating I-125 seeds simulating brachytherapy case studies using the MCNPX code. Int J Cancer Ther Oncol 2014; 2(2:02023.DOI: http://dx.doi.org/10.14319/ijcto.0202.3

  14. Generalised derived limits for radioisotopes of iodine

    International Nuclear Information System (INIS)

    Hughes, J.S.; Haywood, S.M.; Simmonds, J.R.

    1984-04-01

    Generalised Derived Limits (GDLs) are evaluated for iodine-125,129,131,132,133,134,135 in selected materials from the terrestrial and aquatic environments and for discharge to atmosphere. They are intended for use as convenient reference levels against which the results of environmental monitoring can be compared and atmospheric discharges assessed. GDLs are intended for use when the environmental contamination or discharge to atmosphere is less than about 5% of the GDL. If the level of environmental contamination or discharge to the atmosphere exceeds this percentage of the GDL it does not necessarily mean that the dose equivalents to members of the public are approaching the dose equivalent limit. It is rather an indication that it may be appropriate to obtain a more specific derived limit for the particular situation by reviewing the values of the parameters involved in the calculation. GDL values are specified for iodine radionuclides in water, soil, grass, sediments and various foodstuffs derived from the terrestrial and aquatic environments. GDLs are also given for iodine radionuclides on terrestrial surfaces and for their discharge to atmosphere. (author)

  15. Review of options for managing iodine-125 wastes

    International Nuclear Information System (INIS)

    Lock, P.J.; Wakerley, M.W.

    1991-01-01

    Data on the nature, radioactive content and management options used for I-125 wastes that are produced in England and Wales and fall within the provisions of the Radioactive Substances Act 1960 have been collated. The options for, and impacts of the disposal of these wastes have been reviewed and discussed. In addition storage for decay has been reviewed. The necessary storage requirements and methods of storage for the various waste forms have been examined. Conclusions are drawn with respect to the potential/suitability of the various waste management options. (author)

  16. Advancements in brachytherapy

    DEFF Research Database (Denmark)

    Tanderup, Kari; Ménard, Cynthia; Polgar, Csaba

    2017-01-01

    Brachytherapy is a radiotherapy modality associated with a highly focal dose distribution. Brachytherapy treats the cancer tissue from the inside, and the radiation does not travel through healthy tissue to reach the target as with external beam radiotherapy techniques. The nature of brachytherap...

  17. Development of thyroid monitoring system for the measurement of 125I

    International Nuclear Information System (INIS)

    Sankhla, Rajesh; Singh, I.S.; Rao, D.D.; Pradeepkumar, K.S.

    2015-01-01

    Iodine-125 has gained wide acceptance in medical science for diagnosis and therapeutic applications. A considerable number of radiation workers of BARC and BRIT are involved in the production of 125 I and preparation of radio immunoassay (RIA) kits to meet medical requirement of the country. A state of the art Thyroid Monitoring System incorporated with 51 mm diameter x 3 mm thick NaI(Tl) detector is developed for in-vivo monitoring of 125 I in radiation workers handling this radioisotope. The developed system also has provision to accommodate variable body sizes (child to adult). This paper presents the different aspects of the system and its calibration using IAEA neck phantom for estimation of thyroidal content of 125 I. (author)

  18. Preclinical pharmacological study on 125 I-IPPA

    International Nuclear Information System (INIS)

    Wu Chunying; Ji Shuren; Fang Ping; Zhou Xiang; He Yongjun; Cao Guoxian

    1999-01-01

    Myocardial uptake of 125 I-IPPA in rats showed a peak of 4.4% of injected dose per gram. The half elimination time of myocardium was 3.8 min and the maximal uptake of thyroid is only 0.005%ID/organ at 120 min. The initial half time of 2.7 min in rabbits was obtained from the elimination curve of radioactivity in blood. In vitro binding test for 125 I-IPPA to HSA showed rather constant level of activation during tow hours. The second peak of extraction was observed in major organs of rats, in rabbits' elimination of radioactivity and in binding test for 125 I-IPPA to albumin in vivo. Toxicity trial was up to standard. The tolerance of a mouse to IPPA was 560 times as high as that of a person to IPPA. It demonstrated that 125 I-IPPA could be quickly extracted by myocardium, and its catabolite were excreted in the urine with almost no iodine loss. All the results were found to agree with the expectations based on the principal metabolic path of phenyl fatty acid

  19. Comparison of Combined X-Ray Radiography and Magnetic Resonance (XMR) Imaging-Versus Computed Tomography-Based Dosimetry for the Evaluation of Permanent Prostate Brachytherapy Implants

    International Nuclear Information System (INIS)

    Acher, Peter; Rhode, Kawal; Morris, Stephen; Gaya, Andrew; Miquel, Marc; Popert, Rick; Tham, Ivan; Nichol, Janette; McLeish, Kate; Deehan, Charles; Dasgupta, Prokar; Beaney, Ronald; Keevil, Stephen F.

    2008-01-01

    Purpose: To present a method for the dosimetric analysis of permanent prostate brachytherapy implants using a combination of stereoscopic X-ray radiography and magnetic resonance (MR) imaging (XMR) in an XMR facility, and to compare the clinical results between XMR- and computed tomography (CT)-based dosimetry. Methods and Materials: Patients who had received nonstranded iodine-125 permanent prostate brachytherapy implants underwent XMR and CT imaging 4 weeks later. Four observers outlined the prostate gland on both sets of images. Dose-volume histograms (DVHs) were derived, and agreement was compared among the observers and between the modalities. Results: A total of 30 patients were evaluated. Inherent XMR registration based on prior calibration and optical tracking required a further automatic seed registration step that revealed a median root mean square registration error of 4.2 mm (range, 1.6-11.4). The observers agreed significantly more closely on prostate base and apex positions as well as outlining contours on the MR images than on those from CT. Coefficients of variation were significantly higher for observed prostate volumes, D90, and V100 parameters on CT-based dosimetry as opposed to XMR. The XMR-based dosimetry showed little agreement with that from CT for all observers, with D90 95% limits of agreement ranges of 65, 118, 79, and 73 Gy for Observers 1, 2, 3, and 4, respectively. Conclusions: The study results showed that XMR-based dosimetry offers an alternative to other imaging modalities and registration methods with the advantages of MR-based prostate delineation and confident three-dimensional reconstruction of the implant. The XMR-derived dose-volume histograms differ from the CT-derived values and demonstrate less interobserver variability

  20. Curative high dose rate vaginal apex brachytherapy in stage I papillary serous carcinoma of the endometrium

    International Nuclear Information System (INIS)

    Turner, B.C.; Kacinski, B.M.; Gumbs, A.; Peschel, R.E.; Haffty, B.G.; Wilson, L.D.

    1996-01-01

    Introduction: Uterine papillary serous carcinoma (UPSC) is a morphologically distinct variant of endometrial carcinoma that is associated with a poor prognosis, high recurrence rate, clinical understaging, and poor response to salvage treatment. We describe the presentation, local and distant control, survival, salvage rate, and complications for patients undergoing whole abdominal radiation therapy (WART), low dose rate (LDR) intracavitary brachytherapy, or high dose rate (HDR) vaginal brachytherapy in patients with stage I UPSC. Methods: Between 1976 and 1994 more than 1700 patients with endometrial carcinoma were treated with radiation therapy, 30 patients with stage I UPSC (1.8%) were treated with radiation before or following TAH/BSO. All patients underwent either preoperative Simon's packing or tandem and plaque which delivered 30-40 Gy to the serosa, WART, or HDR Ir-192 vaginal apex brachytherapy to a total dose of 21 Gy in 3 fractions at 0.5 cm from the vaginal mucosa. A total of 14 patients received HDR vaginal brachytherapy and (5(14)) patients received systemic chemotherapy. All patients presented with vaginal bleeding at a median age of 67 years (range 34-88). The group of 30 patients underwent TAH/BSO, 17 patients were completely staged pathologically (pelvic and para-aortic lymph nodes, omentectomy, and pelvic washings), and 2 patients underwent omental biopsy and pelvic washings only. All specimens revealed UPSC, nuclear grade 3, and lymphovascular invasion (23%). The pathologic stage was IA: 23% (7), IB: 67% (20), and IC: 10% (3). The median follow-up for all patients was 49 months (range 13-187 months). For the patients receiving postoperative HDR vaginal brachytherapy the median time from surgery to radiation was 42 days (range 29-91). Results: The 5-year actuarial disease free survival for Figo stage I UPSC patients treated with postoperative HDR vaginal brachytherapy and systemic chemotherapy was 100% compared to 74% for stage I UPSC patient

  1. Sexual Function and the Use of Medical Devices or Drugs to Optimize Potency After Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Whaley, J. Taylor; Levy, Lawrence B.; Swanson, David A.; Pugh, Thomas J.; Kudchadker, Rajat J.; Bruno, Teresa L.; Frank, Steven J.

    2012-01-01

    Purpose: Prospective evaluation of sexual outcomes after prostate brachytherapy with iodine-125 seeds as monotherapy at a tertiary cancer care center. Methods and Materials: Subjects were 129 men with prostate cancer with I-125 seed implants (prescribed dose, 145 Gy) without supplemental hormonal or external beam radiation therapy. Sexual function, potency, and bother were prospectively assessed at baseline and at 1, 4, 8, and 12 months using validated quality-of-life self-assessment surveys. Postimplant dosimetry values, including dose to 10% of the penile bulb (D10), D20, D33, D50, D75, D90, and penile volume receiving 100% of the prescribed dose (V100) were calculated. Results: At baseline, 56% of patients recorded having optimal erections; at 1 year, 62% of patients with baseline erectile function maintained optimal potency, 58% of whom with medically prescribed sexual aids or drugs. Variables associated with pretreatment-to-posttreatment decline in potency were time after implant (p = 0.04) and age (p = 0.01). Decline in urinary function may have been related to decline in potency. At 1 year, 69% of potent patients younger than 70 years maintained optimal potency, whereas 31% of patients older than 70 maintained optimal potency (p = 0.02). Diabetes was related to a decline in potency (p = 0.05), but neither smoking nor hypertension were. For patients with optimal potency at baseline, mean sexual bother scores had declined significantly at 1 year (p < 0.01). Sexual potency, sexual function, and sexual bother scores failed to correlate with any dosimetric variable tested. Conclusions: Erections firm enough for intercourse can be achieved at 1 year after treatment, but most men will require medical aids to optimize potency. Although younger men were better able to maintain erections firm enough for intercourse than older men, there was no correlation between potency, sexual function, or sexual bother and penile bulb dosimetry.

  2. Sexual Function and the Use of Medical Devices or Drugs to Optimize Potency After Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Whaley, J. Taylor; Levy, Lawrence B. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Swanson, David A. [Department of Urology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Pugh, Thomas J. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Kudchadker, Rajat J.; Bruno, Teresa L. [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Frank, Steven J., E-mail: sjfrank@mdnaderson.org [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2012-04-01

    Purpose: Prospective evaluation of sexual outcomes after prostate brachytherapy with iodine-125 seeds as monotherapy at a tertiary cancer care center. Methods and Materials: Subjects were 129 men with prostate cancer with I-125 seed implants (prescribed dose, 145 Gy) without supplemental hormonal or external beam radiation therapy. Sexual function, potency, and bother were prospectively assessed at baseline and at 1, 4, 8, and 12 months using validated quality-of-life self-assessment surveys. Postimplant dosimetry values, including dose to 10% of the penile bulb (D10), D20, D33, D50, D75, D90, and penile volume receiving 100% of the prescribed dose (V100) were calculated. Results: At baseline, 56% of patients recorded having optimal erections; at 1 year, 62% of patients with baseline erectile function maintained optimal potency, 58% of whom with medically prescribed sexual aids or drugs. Variables associated with pretreatment-to-posttreatment decline in potency were time after implant (p = 0.04) and age (p = 0.01). Decline in urinary function may have been related to decline in potency. At 1 year, 69% of potent patients younger than 70 years maintained optimal potency, whereas 31% of patients older than 70 maintained optimal potency (p = 0.02). Diabetes was related to a decline in potency (p = 0.05), but neither smoking nor hypertension were. For patients with optimal potency at baseline, mean sexual bother scores had declined significantly at 1 year (p < 0.01). Sexual potency, sexual function, and sexual bother scores failed to correlate with any dosimetric variable tested. Conclusions: Erections firm enough for intercourse can be achieved at 1 year after treatment, but most men will require medical aids to optimize potency. Although younger men were better able to maintain erections firm enough for intercourse than older men, there was no correlation between potency, sexual function, or sexual bother and penile bulb dosimetry.

  3. Brachytherapy of endometrial cancers

    International Nuclear Information System (INIS)

    Peiffert, D.; Hoffstetter, S.; Charra-Brunaud, C.

    2003-01-01

    Endometrial adenocarcinomas rank third as tumoral sites en France. The tumors are confined to the uterus in 80% of the cases. Brachytherapy has a large place in the therapeutic strategy. The gold standard treatment remains extra-fascial hysterectomy with bilateral annexiectomy and bilateral internal iliac lymph node dissection. However, after surgery alone, the rate of locoregional relapses reaches 4-20%, which is reduced to 0-5% after postoperative brachytherapy of the vaginal cuff. This postoperative brachytherapy is delivered as outpatients treatment, by 3 or 4 fractions, at high dose rate. The utero-vaginal preoperative brachytherapy remains well adapted to the tumors which involve the uterine cervix. Patients presenting a localized tumor but not operable for general reasons (< 10%) can be treated with success by exclusive irradiation, which associates a pelvic irradiation followed by an utero-vaginal brachytherapy. A high local control of about 80-90% is obtained, a little lower than surgery, with a higher risk of late complications. Last but not least, local relapses in the vaginal cuff, or in the perimeatic area, can be treated by interstitial salvage brachytherapy, associated if possible with external beam irradiation. The local control is reached in half of the patients, but metastatic dissemination is frequent. We conclude that brachytherapy has a major role in the treatment of endometrial adenocarcinomas, in combination with surgery, or with external beam irradiation for not operable patients or in case of local relapses. It should use new technologies now available including computerized after-loaders and 3D dose calculation. (authors)

  4. Seed Implant Retention Score Predicts the Risk of Prolonged Urinary Retention After Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Lee, Hoon K.; Adams, Marc T.; Shi, Qiuhu; Basillote, Jay; LaMonica, Joanne; Miranda, Luis; Motta, Joseph

    2010-01-01

    Purpose: To risk-stratify patients for urinary retention after prostate brachytherapy according to a novel seed implant retention score (SIRS). Patients and Methods: A total of 835 patients underwent transperineal prostate seed implant from March 1993 to January 2007; 197 patients had 125 I and 638 patients had 103 Pd brachytherapy. Four hundred ninety-four patients had supplemental external-beam radiation. The final downsized prostate volume was used for the 424 patients who had neoadjuvant hormone therapy. Retention was defined as reinsertion of a Foley catheter after the implant. Results: Retention developed in 7.4% of patients, with an average duration of 6.7 weeks. On univariate analysis, implant without supplemental external-beam radiation (10% vs. 5.6%; p = 0.02), neoadjuvant hormone therapy (9.4% vs. 5.4%; p = 0.02), baseline α-blocker use (12.5% vs. 6.3%; p = 0.008), and increased prostate volume (13.4% vs. 6.9% vs. 2.9%, >45 cm 3 , 25-45 cm 3 , 3 ; p = 0.0008) were significantly correlated with increased rates of retention. On multivariate analysis, implant without supplemental external-beam radiation, neoadjuvant hormone therapy, baseline α-blocker use, and increased prostate volume were correlated with retention. A novel SIRS was modeled as the combined score of these factors, ranging from 0 to 5. There was a significant correlation between the SIRS and retention (p < 0.0001). The rates of retention were 0, 4%, 5.6%, 9%, 20.9%, and 36.4% for SIRS of 0 to 5, respectively. Conclusions: The SIRS may identify patients who are at high risk for prolonged retention after prostate brachytherapy. A prospective validation study of the SIRS is planned.

  5. Permanent I-125 interstitial implant in the management of high grade CNS malignancies in children

    International Nuclear Information System (INIS)

    Vaishampayan, N.; Zamorano, L.; Aronin, P.; Gaspar, L.; Canady, A.; Lattin, P.; Ezzell, G.; Yakar, D.; Chungbin, S.; Fontanesi, J.

    1996-01-01

    Purpose/Objective: To evaluate the efficacy and complications associated with the use of permanent I-125 interstitial implants in children with high grade CNS malignancies. Materials and Methods: Between May of 1990 and September of 1994, fourteen children received permanent I-125 interstitial implant brachytherapy as initial therapy (n=8) or at time of recurrence (n=6). Histologies included Glioblastoma Multiforme (n=2), Anaplastic Astrocytoma (n=9) and others (n=3). Pre-implant surgical procedures included: Gross Total Resection (n=2), Subtotal Resection (n=8) or Biopsy alone (n=4). Six patients received pre-implant external beam irradiation (dose range 3,500-6500 cGy) and three patients received post-implant external beam irradiation (dose range 5,040-5,060 cGy). Implant dose range was 8,294-10,368 cGy over the lifetime of the implant (median 10,368 cGy). Results: At last follow-up (median 17.5 months; range 4-56 months), eight children were alive. Six out of the eight had no evidence of disease progression while the remaining had radiologic evidence of progression. Implant complications (n=2) included skin necrosis and bone flap infection. Conclusions: Based on this initial review, we continue to investigate the use of permanent I-125 interstitial brachytherapy in the treatment of high grade CNS malignancies in children and will discuss and compare these results with those of other 'Boost' series

  6. Hospitalary inventory of prostatic sources of I-125

    International Nuclear Information System (INIS)

    Barquero Sanz, R.; Anton, D.; Frutos Baraja, J. de.; Castillo Belmonte, A. del; Alonso, D.; Miquel, D. de; Lopez Lara-Martin, F.

    2013-01-01

    In accordance with the current regulations for radioactive facilities of brachytherapy, to carry out treatments of Prostate with I-125, must be a safety study involving evaluate maximum sources activity to use in the implants. In our installation was requested to perform implants permanent interstitial in prostate patients who tend to leaving the hospital in the hours following the intervention. The request which was prepared taking into account the maximum number predictable treatment (two per week), and to determine the activity to request, it was made the removal of seeds surplus by the supplier after each treatment. (Author)

  7. Gynecological brachytherapy - from low-dose-rate to high-tech. Gynaekologische Brachytherapie - von Low-dose-rate zu High-tech

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, T. (Abt. Strahlenthgerapie, Klinik und Poliklinik fuer Radiologie, Medizinische Akademie ' Carl Gustav Carus' , Dresden (Germany)); Christen, N. (Abt. Strahlenthgerapie, Klinik und Poliklinik fuer Radiologie, Medizinische Akademie ' Carl Gustav Carus' , Dresden (Germany)); Alheit, H.D. (Abt. Strahlenthgerapie, Klinik und Poliklinik fuer Radiologie, Medizinische Akademie ' Carl Gustav Carus' , Dresden (Germany))

    1993-03-01

    The transition from low-dose-rate (LDR) brachytherapy to high-dose-rate (HDR) afterloading treatment is in progress in most centres of radiation therapy. First reports of studies comparing HDR and LDR treatment in cervix cancer demonstrate nearly equal local control. In our own investigations on 319 patients with primary irradiated carcinoma of the cervix (125 HDR/194 LDR) we found the following control rates: Stage FIGO I 95.4%/82.9% (HDR versus LDR), stage FIGO II 71.4%/73.7%, stage FIGO III 57.9%/38.5%. The results are not significant. The side effects - scored after EORT/RTOG criteria - showed no significant differences between both therapies for serious radiogenic late effects on intestine, bladder and vagina. The study and findings from the literature confirm the advantage of the HDR-procedure for patient and radiooncologist and for radiation protection showing at least the same results as in the LDR-area. As for radiobiolgical point of view it is important to consider that the use of fractionation in the HDR-treatment is essential for the sparing of normal tissues and therefore a greater number of small fractionation doses in the brachytherapy should be desirable too. On the other hand the rules, which are true for fractionated percutaneous irradiation therapy (overall treatment time as short as possible to avoid reppopulation of tumor cells) should be taken into consideration in combined brachy-teletherapy regime in gynecologic tumors. The first step in this direction may be accelerated regime with a daily application of both treatment procedures. The central blocking of the brachytherapy region from the whole percutaneous treatment target volume should be critically reflected, especially in the case of advanced tumors. (orig.)

  8. Erectile function after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Galbreath, Robert W.; Stipetich, Robin L.; Abel, Laurie J.; Lief, Jonathan H.

    2002-01-01

    Purpose: To determine the incidence of potency preservation after permanent prostate brachytherapy using a validated patient-administered questionnaire and to evaluate the effect of multiple clinical and treatment parameters on penile erectile function. Methods and Materials: Four hundred twenty-five patients underwent permanent prostate brachytherapy from April 1995 to October 1999. Two hundred nine patients who were potent before brachytherapy and who at the time of the survey were not receiving hormonal therapy were mailed the specific erectile questions of the International Index of Erectile Function (IIEF) questionnaire with a self-addressed stamped envelope. The questionnaire consisted of 5 questions, with a maximal score of 25. Of the 209 patients, 181 (87%) completed and returned the questionnaire. The mean and median follow-up was 40.4±14.9 and 40.6 months, respectively (range 19-75). Preimplant erectile function was assigned using a three-tiered scoring system (2 = erections always or nearly always sufficient for vaginal penetration; 1 = erections sufficient for vaginal penetration but considered suboptimal; 0 = the inability to obtain erections and/or erections inadequate for vaginal penetration). Postimplant potency was defined as an IIEF score ≥11. The clinical parameters evaluated for erectile function included patient age, preimplant potency, clinical T-stage, pretreatment prostate-specific antigen level, Gleason score, elapsed time after implantation, hypertension, diabetes mellitus, and tobacco consumption. Treatment parameters included radiation dose to the prostate gland, use of hormonal manipulation, use of supplemental external beam radiotherapy (EBRT), choice of isotope, prostate volume, and planning volume. The efficacy of sildenafil citrate in brachytherapy-induced erectile dysfunction (ED) was also evaluated. Results: Pretreatment erectile function scores of 2 and 1 were assigned to 125 and 56 patients, respectively. With a 6-year follow

  9. Radiation protection instrumentation. Monitoring equipment. Atmospheric radioactive iodine in the environment

    International Nuclear Information System (INIS)

    1995-01-01

    This international standard applies to portable or installed equipment for the monitoring of radioactive iodine (such as I-131 or I-125) in air in the environment of nuclear installations during normal operation, during design basis events, and in emergency situations. The monitoring involves continuous sample trapping and, where adequate, automatic start of sampling. The document deals with radioactive iodine monitor design, testing procedures, and documentation. Appended tables refer to the reference and normal testing conditions, tests in normal testing conditions, tests during changes of the affecting quantities, and tests of changes in the air circuit. (P.A.)

  10. Computational model of Amersham I-125 source model 6711 and Prosper Pd-103 source model MED3633 using MCNP

    Energy Technology Data Exchange (ETDEWEB)

    Menezes, Artur F.; Reis Junior, Juraci P.; Silva, Ademir X., E-mail: ademir@con.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear; Rosa, Luiz A.R. da, E-mail: lrosa@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Facure, Alessandro [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Cardoso, Simone C., E-mail: Simone@if.ufrj.b [Universidade Federal do Rio de Janeiro (IF/UFRJ), RJ (Brazil). Inst. de Fisica. Dept. de Fisica Nuclear

    2011-07-01

    Brachytherapy is used in cancer treatment at shorter distances through the use of small encapsulated source of ionizing radiation. In such treatment, a radiation source is positioned directly into or near the target volume to be treated. In this study the Monte Carlo based MCNP code was used to model and simulate the I-125 Amersham Health source model 6711 and the Pd-103 Prospera source model MED3633 in order to obtain the dosimetric parameter dose rate constant ({Lambda}) . The sources geometries were modeled and implemented in MCNPX code. The dose rate constant is an important parameter prostate LDR brachytherapy's treatments planning. This study was based on American Association of Physicists in Medicine (AAPM) recommendations which were produced by its Task Group 43. The results obtained were 0.941 and 0.65 for the dose rate constants of I-125 and Pd-103 sources, respectively. They present good agreement with the literature values based on different Monte Carlo codes. (author)

  11. A radiolabeled peptide ligand of the hERG channel, [125I]-BeKm-1

    DEFF Research Database (Denmark)

    Angelo, Kamilla; Korolkova, Yuliya V; Grunnet, Morten

    2003-01-01

    The wild-type scorpion toxin BeKm-1, which selectively blocks human ether-a-go-go related (hERG) channels, was radiolabeled with iodine at tyrosine 11. Both the mono- and di-iodinated derivatives were found to be biologically active. In electrophysiological patch-clamp recordings mono-[127I]-BeKm-1...... had a concentration of half-maximal inhibition (IC50 value) of 27 nM, while wild-type BeKm-1 inhibited hERG channels with an IC50 value of 7 nM. Mono-[125I]-BeKm-1 was found to bind in a concentration-dependent manner and with picomolar affinity to hERG channel protein in purified membrane vesicles...... of [125I]-BeKm-1 to the hERG channel to an IC50 of 7 nM. In autoradiographic studies on rat hearts, binding of [125I]-BeKm-1 was dose-dependent and could partially be displaced by the addition of excess amounts of non-radioactive BeKm-1. The density of the radioactive signal was equally distributed...

  12. Gold nanoparticle-aided brachytherapy with vascular dose painting: estimation of dose enhancement to the tumor endothelial cell nucleus.

    Science.gov (United States)

    Ngwa, Wilfred; Makrigiorgos, G Mike; Berbeco, Ross I

    2012-01-01

    Theoretical microdosimetry at the subcellular level is employed in this study to estimate the dose enhancement to tumor endothelial cell nuclei, caused by radiation-induced photo/Auger electrons originating from gold nanoparticles (AuNPs) targeting the tumor endothelium, during brachytherapy. A tumor vascular endothelial cell (EC) is modeled as a slab of 2 μm (thickness) × 10 μm (length) × 10 μm (width). The EC contains a nucleus of 5 μm diameter and thickness of 0.5-1 μm, corresponding to nucleus size 5%-10% of cellular volume, respectively. Analytic calculations based on the electron energy loss formula of Cole were carried out to estimate the dose enhancement to the nucleus caused by photo/Auger electrons from AuNPs attached to the exterior surface of the EC. The nucleus dose enhancement factor (nDEF), representing the ratio of the dose to the nucleus with and without the presence of gold nanoparticles was calculated for different AuNP local concentrations. The investigated concentration range considers the potential for significantly higher local concentration near the EC due to preferential accumulation of AuNP in the tumor vasculature. Four brachytherapy sources: I-125, Pd-103, Yb-169, and 50 kVp x-rays were investigated. For nucleus size of 10% of the cellular volume and AuNP concentrations ranging from 7 to 140 mg/g, brachytherapy sources Pd-103, I-125, 50 kVp, and Yb-169 yielded nDEF values of 5.6-73, 4.8-58.3, 4.7-56.6, and 3.2-25.8, respectively. Meanwhile, for nucleus size 5% of the cellular volume in the same concentration range, Pd-103, I-125, 50 kVp, and Yb-169 yielded nDEF values of 6.9-79.2, 5.1-63.2, 5.0-61.5, and 3.3-28.3, respectively. The results predict that a substantial dose boost to the nucleus of endothelial cells can be achieved by applying tumor vasculature-targeted AuNPs in combination with brachytherapy. Such vascular dose boosts could induce tumor vascular shutdown, prompting extensive tumor cell death.

  13. Gold nanoparticle-aided brachytherapy with vascular dose painting: Estimation of dose enhancement to the tumor endothelial cell nucleus

    Energy Technology Data Exchange (ETDEWEB)

    Ngwa, Wilfred; Makrigiorgos, G. Mike; Berbeco, Ross I. [Department of Radiation Oncology, Division of Medical Physics and Biophysics, Brigham and Women' s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2012-01-15

    Purpose: Theoretical microdosimetry at the subcellular level is employed in this study to estimate the dose enhancement to tumor endothelial cell nuclei, caused by radiation-induced photo/Auger electrons originating from gold nanoparticles (AuNPs) targeting the tumor endothelium, during brachytherapy. Methods: A tumor vascular endothelial cell (EC) is modeled as a slab of 2 {mu}m (thickness) x 10 {mu}m (length) x 10 {mu}m (width). The EC contains a nucleus of 5 {mu}m diameter and thickness of 0.5-1 {mu}m, corresponding to nucleus size 5%-10% of cellular volume, respectively. Analytic calculations based on the electron energy loss formula of Cole were carried out to estimate the dose enhancement to the nucleus caused by photo/Auger electrons from AuNPs attached to the exterior surface of the EC. The nucleus dose enhancement factor (nDEF), representing the ratio of the dose to the nucleus with and without the presence of gold nanoparticles was calculated for different AuNP local concentrations. The investigated concentration range considers the potential for significantly higher local concentration near the EC due to preferential accumulation of AuNP in the tumor vasculature. Four brachytherapy sources: I-125, Pd-103, Yb-169, and 50 kVp x-rays were investigated. Results: For nucleus size of 10% of the cellular volume and AuNP concentrations ranging from 7 to 140 mg/g, brachytherapy sources Pd-103, I-125, 50 kVp, and Yb-169 yielded nDEF values of 5.6-73, 4.8-58.3, 4.7-56.6, and 3.2-25.8, respectively. Meanwhile, for nucleus size 5% of the cellular volume in the same concentration range, Pd-103, I-125, 50 kVp, and Yb-169 yielded nDEF values of 6.9-79.2, 5.1-63.2, 5.0-61.5, and 3.3-28.3, respectively. Conclusions: The results predict that a substantial dose boost to the nucleus of endothelial cells can be achieved by applying tumor vasculature-targeted AuNPs in combination with brachytherapy. Such vascular dose boosts could induce tumor vascular shutdown, prompting

  14. Brachytherapy in childhood rhabdomyosarcoma treatment

    International Nuclear Information System (INIS)

    Novaes, Paulo Eduardo Ribeiro dos Santos

    1995-01-01

    A retrospective study of 21 children with rhabdomyosarcoma treated by brachytherapy to the primary site of the tumor at the Radiotherapy Department of the A.C.Camargo Hospital between january/1980 to june/1993 was undertaken. The main objectives were to comprove the utility of brachytherapy in childhood rhabdomyosarcoma, to evaluate the local control and survival, in association with chemotherapy, to analyze the late effects of the treatment and to determinate the preferential technique to each clinical situation. All patients received brachytherapy to the tumor site. The radioactive isotopes employed were Gold 198 , Cesium 137 and Iridium 192 . The brachytherapy techniques depended on the tumor site, period of treatment, availability of the radioactive material and stage of the disease. Patients treated exclusively by brachytherapy received 40 Gy to 60 Gy. When brachytherapy was associated with external radiotherapy the dose ranged from 20 Gy to 40 Gy. Local control was achieved in 18 of 20 patients (90%). The global survival and local control survival rates were 61.9% (13/21 patients) and 72,2% (13/18 patients) respectively. (author)

  15. Synthesis of N,N,-didemethylzolpidem-N-{2-{3-(4-hydroxy-3-[125I] iodophenyl)}methyl propionate} for radioimmunoassay

    International Nuclear Information System (INIS)

    De Clerck, I.; Daenens, P.

    1997-01-01

    The 125 I-derivative of zolpidem was prepared by iodination of a L-tyrosine methyl ester conjugate of a zolpidem precursor. The iodinated compound has been used as a tracer molecule in the development of a radioimmunoassay for zolpidem. It was purified by normal phase HPLC, in combination with gamma counting detection. The structure was confirmed by high resolution L-SIMS. (UK)

  16. Posttreatment biopsy results following interstitial brachytherapy in early-stage prostate cancer

    International Nuclear Information System (INIS)

    Prestidge, Bradley R.; Hoak, David C.; Grimm, Peter D.; Ragde, Haakon; Cavanagh, William; Blasko, John C.

    1997-01-01

    Purpose: To assess pathologic control rates for prostatic carcinoma as determined by postimplant prostate biopsy in a large series of consecutive patients who have received permanent interstitial brachytherapy using a contemporary transrectal ultrasound-directed, transperineal, computer generated, volume technique. Methods and Materials: Four hundred and two patients received permanent 125 I or 103 Pd interstitial brachytherapy as primary treatment for early stage prostatic carcinoma at the Northwest Tumor Institute between January 1988 and January 1994. Of these, 201 have consented to biopsy 12 or more months postimplant with a median follow-up of 40 months (range: 12-83 months). None had received homonal manipulation. A total of 361 biopsies was performed on 201 patients with a range of one to six annual biopsies per patient (91 received multiple, serial biopsies). Of the 161 patients more than 12 months postimplant who have not been biopsied, most have been unwilling or unable to submit to biopsy. Only six patients with biochemical progression have not been biopsied. There was no difference in the presenting characteristics or implant parameters between those patients biopsied and those that were not. One hundred and forty-three received 125 I (71%) prescribed to a MPD of 160 Gy with a median activity of 35.5 mCi, and 58 (29%) received 103 Pd prescribed to a MPD of 115 Gy with a median activity of 123 mCi. Multiple biopsies were performed under transrectal ultrasound guidance, and all specimens were classified as either negative, indeterminate, or positive. Results: At the time of last biopsy, 161 (80%) have achieved negative pathology, 34 (17%) remain indeterminate, and 6 (3%) have been positive. Only 2 of the 186 patients with a PSA < 4.0 ng/ml at the time of biopsy were positive. Among those 33 indeterminate patients with a subsequent biopsy, 28 have converted to negative, 2 to positive, and 3 remain unchanged to date. Conclusions: These data demonstrate at

  17. SUFFICIENT IODINE INTAKE IN SCHOOLCHILDREN FROM THE ZAGREB AREA: ASSESSMENT WITH DRIED BLOD SPOT THYROGLOBULIN AS A NEW FUNCTIONAL BIOMARKER FOR IODINE DEFICIENCY.

    Science.gov (United States)

    Jukić, Tomislav; Zimmermann, Michael Bruce; Granić, Roko; Prpić, Marin; Krilić, Drazena; Juresa, Vesna; Katalenić, Marijan; Kusić, Zvonko

    2015-12-01

    Current methods for assessment of iodine intake in a population comprise measurements of urinary iodine concentration (UIC), thyroid volume by ultrasound (US-Tvol), and newborn TSH. Serum or dried blood spot thyroglobulin (DBS-Tg) is a new promising functional iodine status biomarker in children. In 1996, a new act on universal salt iodination was introduced in Croatia with 25 mg of potassium iodideper kg of salt. In 2002, Croatia finally reached iodine sufficiency. However, in 2009, median UIC in 101 schoolchildren from Zagreb, the capital of Croatia, was 288 µg/L, posing to be excessive. The aim of the study was to assess iodine intake in schoolchildren from the Zagreb area and to evaluate the value of DBS-Tg in schoolchildren as a new functional biomarker of iodine deficiency (and iodine excess). The study was part of a large international study in 6- to 12-year-old children supported by UNICEF, the Swiss Federal Institute of Technology (ETH Zurich) and the International Council for the Control of Iodine Deficiency Disorders (ICCIDD). According to international study results, the median cut-off Tg 40 µg/L indicate iodine sufficiency. The study included 159 schoolchildren (median age 9.1 ± 1.4 years) from Zagreb and a nearby small town of Jastrebarsko with measurements of UIC, US-Tvol, DBS-Tg, T4, TSH and iodine content in salt from households of schoolchildren (KI/kg of salt). Overall median UIC was 205 µg/L (range 1-505 µg/L). Thyroid volumes in schoolchildren measured by US were within the normal range according to reference values. Median DBS-Tg in schoolchildren was 12.1 µg/L with 3% of Tg values > 40 µg/L. High Tg values were in the UIC range 300 µg/L (U-shaped curve of Tg plotted against UIC). All children were euthyroid with geometric mean TSH 0.7 ± 0.3 mU/L and arithmetic mean T4 62 ± 12.5 nmol/L. The mean KI content per kg of salt was 24.9 ± 3.1 mg/kg (range 19-36 mg/kg). Study results indicated iodine sufficiency in schoolchildren from the

  18. Radiation protection after interstitial permanent prostate brachytherapy implants

    Energy Technology Data Exchange (ETDEWEB)

    Pirraco, R.; Pereira, A.; Cavaco, A. [Instituto Portugues de Oncologia Francisco Gentil - Centro R egional de Oncologia do Porto, SA, Porto (Portugal)

    2006-07-01

    Full text of publication follows: In this study we measure patients radiation exposure dose after interstitial {sup 125}I permanent prostate Brachytherapy implants, and correlate it with dose limits for public, total activity implanted, patient preoperative weight(1), distance between prostate walls and anterior skin surface. Methods and Material: We analyse 20 patients who were implanted with {sup 125}I seeds. The instrument used to measure radiation is a calibrated Berthold Umo LB 123 aco-plated to a LB 1236-H10 detector. Three measurements were taken: at the perineal and anterior pelvic zones on contact with the skin and at 1 m from the patient. The maximum value was taken for all measurements. The dose at a distance of one meter is obtained at anterior pelvic zone, perpendicular to the skin, according to the recommendations of A.A.P.M.(1). The distance between prostate walls was determined using post -operative CT images. Results: The doses at the perineal zone have determined an average of 186 {mu}Sv/h (range: 110 340 {mu}Sv/h) and at surface pelvic zone of 41 {mu}Sv/h (range: 15 103 {mu}Sv/h). The dose at a distance of 1 meter has an average value of 0.4 {mu}Sv/h (range: 0.2 1.0 {mu}Sv/h). The average total activity implanted was 25 mCi (range: 17 38 mCi). The distance between prostate walls and skin pelvic surface of the patients has an average value of 8.9 cm (range: 6.6 -11.5 cm). At a distance of 1 meter from the pelvic zone the dose measured is very low and below dose limits imposed by the European Directive EURATOM 2 and the Portuguese law. For general public to reach annual dose limit (EURATOM - 1 mSv/year) when contacting the pelvic zone, we extrapolate that 4 days (range: 1.6 11.1 days) would be needed, assuming a daily contact period of 6 hours. Conclusion: We established a correlation between the distance of prostate walls to the skin perineal surface and the total dose, but we find no correlation between measured doses, total activity implanted

  19. Roles of microbial activities on the distribution and speciation of iodine in the soil environment

    International Nuclear Information System (INIS)

    Muramatsu, Yasuyuki; Yoshida, Satoshi; Amachi, Seigo

    2000-01-01

    The chemical species of iodine in the environment are expected to be influenced by the activities of microorganisms. In this paper, the roles of microbial activities in the accumulation and loss of iodine in soils were studied. Concentrations of stable iodine in several types of soils were determined by ICP-MS (Inductively Coupled Plasma Mass Spectroscopy). High iodine concentrations were found in upland soils, particularly in Andosol, while the concentrations in lowland soils were considerably lower. Accumulation of iodine in soils was explained by the effects of microorganisms and/or their products (e.g. enzymes). Iodine was observed to be desorbed from the flooded soils due to the reducing conditions (low Eh) created by the microbial activities. From the soil-rice plant system biogenesis methyliodide was found to be evaporated into the atmosphere. In order to study the mechanisms of volatile iodine production from the soil environment, a reliable method using 125 I tracer was established. Soil solution and bacterial cell suspension were incubated using this method, and it was found that volatile organic iodine was produced due to microbial activities (including bacterial activities). (author)

  20. Implant volume as a prognostic variable in brachytherapy decision-making for malignant gliomas stratified by the RTOG recursive partitioning analysis

    International Nuclear Information System (INIS)

    Videtic, Gregory M.M.; Gaspar, Laurie E.; Zamorano, Lucia; Stitt, Larry W.; Fontanesi, James; Levin, Kenneth J.

    2001-01-01

    Purpose: When an initial retrospective review of malignant glioma patients (MG) undergoing brachytherapy was carried out using the Radiation Therapy Oncology Group (RTOG) recursive partitioning analysis (RPA) criteria, it revealed that glioblastoma multiforme (GBM) cases benefit the most from implant. In the present study, we focused exclusively on these GBM patients stratified by RPA survival class and looked at the relationship between survival and implanted target volume, to distinguish the prognostic value of volume in general and for a given GBM class. Methods and Materials: Between 1991 and 1998, 75 MG patients were treated with surgery, external beam radiation, and stereotactic iodine-125 (I-125) implant. Of these, 53 patients (70.7%) had GBMs, with 52 (98%) having target volume (TV) data for analysis. Stratification by RPA criteria showed 12, 26, 13, and 1 patients in classes III to VI, respectively. For analysis purposes, classes V and VI were merged. There were 27 (51.9%) male and 25 (48.1%) female patients. Mean age was 57.5 years (range 14-79). Median Karnofsky performance status (KPS) was 90 (range 50-100). Median follow-up time was 11 months (range 2-79). Results: At analysis, 18 GBM patients (34.6%) were alive and 34 (65.4%) were dead. Two-year and 5-year survivals were 42% and 17.5%, respectively, with a median survival time (MST) of 16 months. Two-year survivals and MSTs for the implanted GBM patients compared to the RTOG database were as follows: 74% vs. 35% and 28 months vs. 17.9 months for class III; 32% vs. 15% and 16 months vs. 11.1 months for class IV; 29% vs. 6% and 11 months vs. 8.9 months for class V/VI. Mean implanted TV was 15.5 cc (range 0.8-78), which corresponds to a spherical implant diameter of 3.1 cm. Plotting survival as a function of 5-cc TV increments suggested a trend toward poorer survival as the implanted volume increases. The impact of incremental changes in TV on survival within a given RPA class of GBMs was compared to the