WorldWideScience

Sample records for iodine-123 iodobenzamide single-photon

  1. Assessment of endogenous dopamine release by methylphenidate challenge using iodine-123 iodobenzamide single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Booij, J. [Graduate School of Neurosciences, Department of Nuclear Medicine, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Korn, P. [Graduate School of Neurosciences, Department of Nuclear Medicine, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Linszen, D.H. [Department of Psychiatry, Academic Medical Center, Tafelbergweg 25, 1105 BC Amsterdam (Netherlands); Royen, E.A. van [Graduate School of Neurosciences, Department of Nuclear Medicine, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands)

    1997-06-10

    This double-blind, placebo-controlled study assessed pharmacologically induced endogenous dopamine (DA) release in healthy male volunteers (n=12). Changes in endogenous DA release after injection of the psychostimulant drug methylphenidate were evaluated by single-photon emission tomography (SPET) and constant infusion of iodine-123 iodobenzamide ([{sup 123}I]IBZM), a D{sub 2}receptor radioligand that is sensitive to endogenous DA release. Methylphenidate induced displacement of striatal [ {sup 123}I]IBZM binding, resulting in a significantly decrease in the specific to non-specific [ {sup 123}I]IBZM uptake ratio (average: 8.6%) in comparison with placebo (average: -1.9%). Moreover, injection of methylphenidate induced significant behavioural responses on the following items: excitement, anxiety, tension, and mannerisms and posturing. The results of this study demonstrate the feasibility of using constant infusion of [ {sup 123}I]IBZM and SPET imaging to measure endogenous DA release after methylphenidate challenge and to investigate neurochemical aspects of behaviour. (orig.). With 2 figs., 1 tab.

  2. Assessment of endogenous dopamine release by methylphenidate challenge using iodine-123 iodobenzamide single-photon emission tomography

    International Nuclear Information System (INIS)

    Booij, J.; Korn, P.; Linszen, D.H.; Royen, E.A. van

    1997-01-01

    This double-blind, placebo-controlled study assessed pharmacologically induced endogenous dopamine (DA) release in healthy male volunteers (n=12). Changes in endogenous DA release after injection of the psychostimulant drug methylphenidate were evaluated by single-photon emission tomography (SPET) and constant infusion of iodine-123 iodobenzamide ([ 123 I[IBZM), a D 2 receptor radioligand that is sensitive to endogenous DA release. Methylphenidate induced displacement of striatal [ 123 I[IBZM binding, resulting in a significantly decrease in the specific to non-specific [ 123 I[IBZM uptake ratio (average: 8.6%) in comparison with placebo (average: -1.9%). Moreover, injection of methylphenidate induced significant behavioural responses on the following items: excitement, anxiety, tension, and mannerisms and posturing. The results of this study demonstrate the feasibility of using constant infusion of [ 123 I[IBZM and SPET imaging to measure endogenous DA release after methylphenidate challenge and to investigate neurochemical aspects of behaviour. (orig.). With 2 figs., 1 tab

  3. Assessment of endogenous dopamine release by methylphenidate challenge using iodine-123 iodobenzamide single-photon emission tomography

    NARCIS (Netherlands)

    Booij, J.; Korn, P.; Linszen, D. H.; van Royen, E. A.

    1997-01-01

    This double-blind, placebo-controlled study assessed pharmacologically induced endogenous dopamine (DA) release in healthy male volunteers (n=12). Changes in endogenous DA release after injection of the psychostimulant drug methylphenidate were evaluated by single-photon emission tomography (SPET)

  4. In vivo effects of olanzapine on striatal dopamine D[sub 2]/D[sub 3] receptor binding in schizophrenic patients: an iodine-123 iodobenzamide single-photon emission tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Dresel, S.; Rossmueller, B.; Hahn, K.; Tatsch, K. (Department of Nuclear Medicine, University of Munich (Germany)); Mager, T.; Meisenzahl, E.; Moeller, H.J. (Department of Psychiatry, University of Munich (Germany))

    1999-08-01

    Olanzapine is a new atypical antipsychotic agent that belongs to the same chemical class as clozapine. The pharmacological efficacy of olanzapine (in contrast to that of risperidone) has been shown to be comparable to that of clozapine, but olanzapine has the advantage of producing a less pronounced bone marrow depressing effect than clozapine. The specific aims of this study were (a) to assess dopamine D[sub 2]/D[sub 3] receptor availability in patients treated with olanzapine by means of iodine-123 iodobenzamide [[sup 123]I]IBZM single-photon emission tomography (SPET), (b) to compare the results with findings of [[sup 123]I]IBZM SPET in patients under treatment with risperidone and (c) to correlate the results with the occurrance of extrapyramidal side-effects (EPMS). Brain SPET scans were performed in 20 schizophrenic patients (DSM III R) at 2 h after i.v. administration of 185 MBq [[sup 123]I]IBZM. Images were acquired using a triple-head gamma camera (Picker Prism 3000 XP). For semiquantitative evaluation of D[sub 2]/D[sub 3] receptor binding, transverse slices corrected for attenuation were used to calculate specific uptake values [STR-BKG]/BKG (STR=striatum; BKG=background). The mean daily dose of olanzapine ranged from 0.05 to 0.6 mg/kg body weight. The dopamine D[sub 2]/D[sub 3] receptor binding was reduced in all patients treated with olanzapine. Specific IBZM binding [STR-BKG]/BKG ranged from 0.13 to 0.61 (normal controls >0.95). The decreased D[sub 2]/D[sub 3] receptor availability revealed an exponential dose-response relationship (r=-0.85, P<0.001). The slope of the curve was similar to that of risperidone and considerably higher than that of clozapine as compared with the results of a previously published study. EPMS were observed in only one patient, presenting with the lowest D[sub 2]/D[sub 3] availability. The frequency of EPMS induced by olanzapine (5%) was considerably lower than the frequency under risperidone treatment (40%). Our findings

  5. In vivo effects of olanzapine on striatal dopamine D{sub 2}/D{sub 3} receptor binding in schizophrenic patients: an iodine-123 iodobenzamide single-photon emission tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Dresel, S.; Rossmueller, B.; Hahn, K.; Tatsch, K. [Department of Nuclear Medicine, University of Munich (Germany); Mager, T.; Meisenzahl, E.; Moeller, H.J. [Department of Psychiatry, University of Munich (Germany)

    1999-08-01

    Olanzapine is a new atypical antipsychotic agent that belongs to the same chemical class as clozapine. The pharmacological efficacy of olanzapine (in contrast to that of risperidone) has been shown to be comparable to that of clozapine, but olanzapine has the advantage of producing a less pronounced bone marrow depressing effect than clozapine. The specific aims of this study were (a) to assess dopamine D{sub 2}/D{sub 3} receptor availability in patients treated with olanzapine by means of iodine-123 iodobenzamide [{sup 123}I]IBZM single-photon emission tomography (SPET), (b) to compare the results with findings of [{sup 123}I]IBZM SPET in patients under treatment with risperidone and (c) to correlate the results with the occurrance of extrapyramidal side-effects (EPMS). Brain SPET scans were performed in 20 schizophrenic patients (DSM III R) at 2 h after i.v. administration of 185 MBq [{sup 123}I]IBZM. Images were acquired using a triple-head gamma camera (Picker Prism 3000 XP). For semiquantitative evaluation of D{sub 2}/D{sub 3} receptor binding, transverse slices corrected for attenuation were used to calculate specific uptake values [STR-BKG]/BKG (STR=striatum; BKG=background). The mean daily dose of olanzapine ranged from 0.05 to 0.6 mg/kg body weight. The dopamine D{sub 2}/D{sub 3} receptor binding was reduced in all patients treated with olanzapine. Specific IBZM binding [STR-BKG]/BKG ranged from 0.13 to 0.61 (normal controls >0.95). The decreased D{sub 2}/D{sub 3} receptor availability revealed an exponential dose-response relationship (r=-0.85, P<0.001). The slope of the curve was similar to that of risperidone and considerably higher than that of clozapine as compared with the results of a previously published study. EPMS were observed in only one patient, presenting with the lowest D{sub 2}/D{sub 3} availability. The frequency of EPMS induced by olanzapine (5%) was considerably lower than the frequency under risperidone treatment (40%). Our findings

  6. Iodine-123-iodobenzamide imaging, MRI and apomorphine testing in the evaluation of patients with Parkinsonism

    International Nuclear Information System (INIS)

    Van der Schaaf, A.A.; Stell, R.; Groom, G.N.; Lambrecht, R.; Najdovski, L.; Cardaci, G.; Davis, S.; Dikic, B.; Laing, B.; Mastaaglia, F.L.; O''Brein, J.

    1998-01-01

    Full text: Idiopathic Parkinson''s disease (IPD) is characterised by a loss of dopaminergic neurons in the substantia nigra. Other neurodegenerative disorders may mimic IPD, and the clinical distinction is important in patient management. Iodine-123-iodobenzamide (IBZM) has high specific binding to dopamine-2 (D2) receptors enabling SPECT studies of these receptors in the human brain. A significant reduction of D2 receptor binding of 123 I-lBZM has been shown in the basal ganglia of patients with Parkinsonian syndromes (PS) but normal uptake is seen in patients with IPD. Iodine-123-lBZM SPECT imaging has been proposed as a means of distinguishing between patients with IPD and PS and may be of value in predicting the long-term responsiveness to dopaminergic drugs. Magnetic resonance imaging has also been used to distinguish IPD from PS, and apomorphine testing is in use as a clinical means of predicting response to dopaminergic drugs. We plan to evaluate the sensitivity and specificity of 123 I-lBZM SPECT, MRI and apomorphine testing for categorisation of patients and the prediction of responsiveness to dopaminergic drugs. To date we have studied 17 patients. SPECT imaging of the brain was carried out two hours after the i.v. administration of 185 MBq of 123 I-lBZM and visual and semi-quantitative analysis, using ratios of uptake in basal ganglia to frontal cortex, occipital cortex and cerebellum have been carried out. Although the data are incomplete, preliminary results suggest that there is a poor correlation of 123 I-lBZM uptake with the provisional clinical diagnosis and with apomorphine testing, but that 123 I-lBZM uptake is a predictor of dopaminergic response

  7. Multivariate cluster analysis of dynamic iodine-123 iodobenzamide SPET dopamine D{sub 2}receptor images in schizophrenia

    Energy Technology Data Exchange (ETDEWEB)

    Acton, P.D. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom); Pilowsky, L.S. [Institute of Psychiatry, London (United Kingdom); Costa, D.C. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom); Ell, P.J. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom)

    1997-02-01

    This paper describes the application of a multivariate statistical technique to investigate striatal dopamine D{sub 2}receptor concentrations measured by iodine-123 iodobenzamide ({sup 123}I-IBZM) single-photon emission tomography (SPET). This technique enables the automatic segmentation of dynamic nuclear medicine images based on the underlying time-activity curves present in the data. Once the time-activity curves have been extracted, each pixel can be mapped back on to the underlying distribution, considerably reducing image noise. Cluster analysis has been verified using computer simulations and phantom studies. The technique has been applied to SPET images of dopamine D {sub 2}receptors in a total of 20 healthy and 20 schizophrenic volunteers (22 male, 18 female), using the ligand {sup 123}I-IBZM. Following automatic image segmentation, the concentration of striatal dopamine D {sub 2}receptors shows a significant left-sided asymmetry in male schizophrenics compared with male controls. The mean left-minus-right laterality index for controls is -1.52 (95% CI -3.72-0.66) and for patients 4.04 (95% CI 1.07-7.01). Analysis of variance shows a case-by-sex-by-side interaction, with F=10.01, P=0.005. We can now demonstrate that the previously observed male sex-specific D {sub 2}receptor asymmetry in schizophrenia, which had failed to attain statistical significance, is valid. Cluster analysis of dynamic nuclear medicine studies provides a powerful tool for automatic segmentation and noise reduction of the images, removing much of the subjectivity inherent in region-of-interest analysis. The observed striatal D {sub 2}asymmetry could reflect long hypothesized disruptions in dopamine-rich cortico-striatal-limbic circuits in schizophrenic males. (orig.). With 4 figs., 2 tabs.

  8. Iodine-123 metaiodobenzylguanidine scintigraphy and iodine-123 ioflupane single photon emission computed tomography in Lewy body diseases: complementary or alternative techniques?

    Science.gov (United States)

    Treglia, Giorgio; Cason, Ernesto; Cortelli, Pietro; Gabellini, Anna; Liguori, Rocco; Bagnato, Antonio; Giordano, Alessandro; Fagioli, Giorgio

    2014-01-01

    To compare myocardial sympathetic imaging using (123)I-Metaiodobenzylguanidine (MIBG) scintigraphy and striatal dopaminergic imaging using (123)I-Ioflupane (FP-CIT) single photon emission computed tomography (SPECT) in patients with suspected Lewy body diseases (LBD). Ninety-nine patients who performed both methods within 2 months for differential diagnosis between Parkinson's disease (PD) and other parkinsonism (n = 68) or between dementia with Lewy bodies (DLB) and other dementia (n = 31) were enrolled. Sensitivity, specificity, accuracy, positive and negative predictive values of both methods were calculated. For (123) I-MIBG scintigraphy, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 83%, 79%, 82%, 86%, and 76%, respectively. For (123)I-FP-CIT SPECT, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 93%, 41%, 73%, 71%, and 80%, respectively. There was a statistically significant difference between these two methods in patients without LBD, but not in patients with LBD. LBD usually present both myocardial sympathetic and striatal dopaminergic impairments. (123)I-FP-CIT SPECT presents high sensitivity in the diagnosis of LBD; (123)I-MIBG scintigraphy may have a complementary role in differential diagnosis between PD and other parkinsonism. These scintigraphic methods showed similar diagnostic accuracy in differential diagnosis between DLB and other dementia. Copyright © 2012 by the American Society of Neuroimaging.

  9. A Family with Von Hippel-Lindau Syndrome: The Findings of Indium-111 Somatostatin Receptor Scintigraphy, Iodine-123 Metaiodobenzylguanidine Scintigraphy and Single Photon Emission Computerized Tomography

    Directory of Open Access Journals (Sweden)

    Pelin Arıcan

    2017-02-01

    Full Text Available Von Hippel-Lindau syndrome (VHLS is an autosomal dominant hereditary familial disorder characterized by development of malignant and benign neoplasms. Differential diagnosis of the adrenal and pancreatic masses are difficult in patients with VHLS. Iodine-123 metaiodobenzylguanidine (I-123 MIBG and indium-111 somatostatin receptor scintigraphies (In-111 SRS have important roles in the differential diagnosis of adrenal and pancreatic masses in those patients. In this case report, we present the findings of I-123 MIBG single-photon emission computerized tomography (SPECT/CT and In-111 SRS SPECT/CT in three members of a family with VHLS. In case 1, a residual neuroendocrine tumor (NET was detected in the head of pancreas on In-111 SRS SPECT/CT images. In case 2 and 3, I-123 MIBG SPECT/CT confirmed the adrenal masses as pheochromocytoma, and the extra-adrenal mass as NET, before surgery. We thought that In-111 SRS and I-123 MIBG scan might be helpful in the routine work up of VHLS patients for diagnostic and therapeutic purposes. Hybrid SPECT/CT system may improve diagnostic accuracy of planar images since it assesses morphologic and functional information together.

  10. Iodine-123 phenylpentadecanoic acid: detection of acute myocardial infarction and injury in dogs using an iodinated fatty acid and single-photon emission tomography

    International Nuclear Information System (INIS)

    Rellas, J.S.; Corbett, J.R.; Kulkarni, P.

    1983-01-01

    The ability of an iodinated fatty acid, iodine-123 phenylpentadecanoic acid (1-123 PPA), and single-photon emission computed tomography (SPECT) to detect myocardium injured by temporary or permanent coronary arterial occlusion was evaluated. In 5 control dogs, 11 dogs that underwent 90 to 120 minutes of fixed left anterior descending coronary artery (LAD) occlusion, and 8 dogs that underwent 90 minutes of temporary LAD occlusion and up to 90 minutes of reflow, 2 to 6 mCi of I-123 PPA were injected and the dogs were imaged with SPECT. Control dogs showed relatively uniform uptake and clearance of I-123 PPA in similar left ventricular (LV) regions. Dogs with permanent LAD occlusion were identified by computer algorithm as having regions of decreased I-123 PPA uptake in the infarct-related area and a reduced rate of I-123 PPA clearance (-9.4% in infarct sectors [washin], +3.7% in sectors adjacent to the area of infarction, and +15.4% in control LV sectors [p less than 0.01]). Dogs with temporary LAD occlusion and reperfusion had decreased clearance of I-123 PPA from the regions with infarction; I-123 PPA clearance was -5.2 +/- 16.4% in infarct sectors, 12.7 +/- 7.4% in periinfarct zones, and 30.4 +/- 12% in control LV regions. These data demonstrate that tomographic analysis of I-123 PPA uptake and clearance permits the relatively noninvasive detection of LV myocardium injured by permanent or temporary LAD occlusion and reperfusion

  11. Decrease in benzodiazepine receptor binding in a patient with Angelman syndrome detected by iodine-123 iomazenil and single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Odano, Ikuo [Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan); Anezaki, Toshiharu [Dept. of Neurology, Brain Research Inst., Niigata Univ., Niigata (Japan); Ohkubo, Masaki [Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan); Yonekura, Yoshiharu [Nihon Medi-Physics Co. Ltd., Hyogo (Japan); Onishi, Yoshihiro [Biomedical Imaging Research Center, Fukui Medical School, Fukui (Japan); Inuzuka, Takashi [Dept. of Neurology, Brain Research Inst., Niigata Univ., Niigata (Japan); Takahashi, Makoto [Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan); Tsuji, Shoji [Dept. of Neurology, Brain Research Inst., Niigata Univ., Niigata (Japan)

    1996-05-01

    A receptor mapping technique using iodine-123 iomazenil and single-photon emission tomography (SPET) was employed to examine benzodiazepine receptor binding in a patient with Angelman syndrome (AS). AS is characterized by developmental delay, seizures, inappropriate laughter and ataxic movement. In this entity there is a cytogenic deletion of the proximal long arm of chromosome 15q11-q13, where the gene encoding the GABA{sub A} receptor {beta}3 subunit (GABRB3) is located. Since the benzodiazepine receptor is constructed as a receptor-ionophore complex that contains the GABA{sub A} receptor, it is a suitable marker for GABA-ergic synapsis. To determine whether benzodiazepine receptor density, which indirectly indicates changes in GABA{sub A} receptor density, is altered in the brain in patients with AS, we investigated a 27-year-old woman with AS using {sup 123}I-iomazenil and SPET. Receptor density was quantitatively assessed by measuring the binding potential using a simplified method. Regional cerebral blood flow was also measured with N-isopropyl-p-[{sup 123}]iodoamphetamine. We demonstrated that benzodiazepine receptor density is severely decreased in the cerebellum, and mildly decreased in the frontal and temporal cortices and basal ganglia, a result which is considered to indicate decreased GABA{sub A} receptor density in these regions. Although the deletion of GABRB3 was not observed in the present study, we indirectly demonstrated the disturbance of inhibitory neurotransmission mediated by the GABA{sub A} receptor in the investigated patient. {sup 123}I-iomazenil with SPET was useful to map benzodiazepine receptors, which indicate GABA{sub A} receptor distribution and their density. (orig.)

  12. Analysis of regional cerebral blood flow and distribution volume in Machado-Joseph disease by iodine-123I IMP single photon emission computed tomography

    International Nuclear Information System (INIS)

    Hayashi, Tsunemi; Nakajima, Takashi; Fukuhara, Nobuyoshi

    2001-01-01

    Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (V d ) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP ( 123 I-IMP) single photon emission computed tomography (SPECT). Representative cases were as follows: A 46-year-old woman first experienced gait ataxia at age 38. Computed tomography (CT) and magnetic resonance imaging (MRI) showed no atrophy in the pons or cerebellum, but rCBF measured by the 123 I-IMP SPECT ARG method detected hypoperfusion in the pons, and cerebellar vermis and hemisphere. A 76-year-old woman first experienced gait ataxia at age 69. CT and MRI findings showed severe atrophy in the pons, and cerebellar vermis and hemisphere. Moreover, rCBF was decreased in the pons, whereas it was not decreased in the cerebellar vermis and hemisphere. In the pons of patients with MJD, rCBF was markedly decreased regardless of disease severity. Because this SPECT finding for the pons looked like a 'dot', we have called it the 'pontine dot sign'. In the MJD group, rCBF was significantly decreased in the pons (Student's t test, p d was also significantly decreased in the pons (p d for the pons and age at onset (r=0.59, p d in the cerebellar hemispheres and International Cooperative Ataxia Rating Scale (r=0.644, p d obtained by 123 I-IMP SPECT for patients with MJD identified by gene analysis. Our study shows that SPECT measurement of rCBF and V d is useful for understanding the pathophysiology of MJD. (author)

  13. Association of Novelty Seeking Scores and Striatal Dopamine D2/D3 Receptor Availability of Healthy Volunteers: Single Photon Emission Computed Tomography With 123I-iodobenzamide

    Directory of Open Access Journals (Sweden)

    Hsiang Yu Huang

    2010-10-01

    Full Text Available It has been speculated that novelty seeking (NS behavior is related to the dopaminergic system. Fifty-two subjects completed the Tridimensional Personality Questionnaire and underwent single photon emission computed tomography with 123I-iodobenzamide. A marginally positive correlation was noted between NS and striatal dopamine D2/D3 receptor availability (r = 0.25, p =0.07. A positive association was noted between the NS scores and left striatal D2/D3 receptor availability (r= 0.29, p =0.04. The results suggest that a relationship might exist between NS score and dopaminergic activity.

  14. Initial experience with single-photon emission tomography using iodine-123-labelled 2β-carbomethoxy-3β(4-iodophnyl)tropane in human brain

    International Nuclear Information System (INIS)

    Kuikka, J.T.; Bergstroem, K.A.; Vanninen, E.; Laulumaa, V.; Hartikainen, P.; Laensimies, E.

    1993-01-01

    The iodinated cocaine analogue 2β-carbomethoxy-3β-(4-iodophenyl)tropane ([ 123 I]β-CIT), a new dopamine transporter, was preliminarily tested in human brain. Two normal volunteers and two patients with Parkinson's disease were imaged with a high-resolution single-photon emission tomography scanner. The specific binding of [ 123 I]β-CIT in the basal ganglia and thalamus was high in normal volunteers. In addition, there was relatively intense uptake in the medial prefrontal area. Patients with Parkinson's disease who were older than controls showed significantly lower specific binding in the basal ganglia and thalamus and no uptake in the medial prefrontal cortex. This decrease in the dopamine transporter may be age related. (orig.)

  15. Demonstration of a reduction in muscarinic receptor binding in early Alzheimer's disease using iodine-123 dexetimide single-photon emission tomography

    International Nuclear Information System (INIS)

    Claus, J.J.; Dubois, E.A.; Booij, J.; Habraken, J.; Munck, J.C. van; Herk, M. van; Verbeeten, B. Jr.; Royen, E.A. van

    1997-01-01

    Decreased muscarinic receptor binding has been suggested in single-photon emission tomography (SPET) studies of Alzheimer's disease. However, it remains unclear whether these changes are present in mildly demented patients, and the role of cortical atrophy in receptor binding assessment has not been investigated. We studied muscarinic receptor binding normalized to neostriatum with SPET using [ 123 I[4-iododexetimide in five mildly affected patients with probable Alzheimer's disease and in five age-matched control subjects. Region of interest (ROI) analysis was performed in a consensus procedure blind to clinical diagnosis using matched magnetic resonance (MRI) images. Cortical atrophy was assessed by calculating percentages of cerebrospinal fluid in each ROI. An observer study with three observers was conducted to validate this method. Alzheimer patients showed statistically significantly less [ 123 I[4-iododexetimide binding in left temporal and right temporo-parietal cortex compared with controls, independent of age, sex and cortical atrophy. Mean intra-observer variability was 3.6% and inter-observer results showed consistent differences in [ 123 I[4-iododexetimide binding between observers. However, differences between patients and controls were comparable among observers and statistically significant in the same regions as in the consensus procedure. Using an MRI-SPET matching technique, we conclude that [ 123 I[4-iododexetimide binding is reduced in patients with mild probable Alzheimer's disease in areas of temporal and temporo-parietal cortex. (orig.). With 1 fig., 4 tabs

  16. Iodine-123 N-methyl-4-iododexetimide: a new radioligand for single-photon emission tomographic imaging of myocardial muscarinic receptors

    International Nuclear Information System (INIS)

    Hicks, R.J.; Kassiou, M.; Eu, P.; Katsifis, A.G.; Garra, M.; Power, J.; Najdovski, L.; Lambrecht, R.M.

    1995-01-01

    Cardiac muscarinic receptor ligands suitable for positron emission tomography have previously been characterised. Attempts to develop radioligands of these receptors suitable for single-photon emission tomographic (SPET) imaging have not been successful due to high lung retention and high non-specific binding of previously investigated potential tracers. The purpose of this study was to evaluate the biodistribution and in vivo imaging characteristics of a new radiopharmaceutical, [ 123 I]N-methyl-4-iododexetimide. Biodistribution studies performed in rats showed high cardiac uptake (2.4% ID/g) 10 min after injection with a heart to lung activity ratio of 5:1. Specificity and stereoselectivity of cardiac binding were demonstrated using blocking experiments in rats. Dynamic imaging studies in anaesthetised greyhounds demonstrated rapid and high myocardial uptake and low lung binding with stable heart to lung activity ratios of >2.5:1 between 10 and 30 min, making SPET imaging feasible. Administration of an excess of an unlabelled muscarinic antagonist, methyl-quinuclidinyl benzylate rapidly displaced myocardial activity to background levels and the pharmacologically inactive enantiomer, [ 123 I]N-methyl-4-iodolevetimide, had no detectable cardiac uptake, indicating specific and stereoselective muscarinic receptor binding. SPET revealed higher activity in the inferior than in the anterior wall, this being consistent with previously described regional variation of cardiac parasympathetic innervation. [ 123 I]N-methyl-4-iododexetimide shows promise as an imaging agent for muscarinic receptor distribution in the heart and may be helpful in evaluating diverse cardiac diseases associated with altered muscarinic receptor function, including heart failure and diabetic heart disease. (orig.)

  17. Striatal dopamine release in reading and writing measured with [123I]iodobenzamide and single photon emission computed tomography in right handed human subjects.

    Science.gov (United States)

    Schommartz, B; Larisch, R; Vosberg, H; Müller-Gärtner, H M

    2000-09-29

    Competition between endogenous dopamine and a radioligand for postsynaptic dopamine D(2) receptor binding was examined in two groups of eight subjects each who had to read or write off a text, respectively, and in a control group. Single photon emission computed tomography (SPECT) and the ligand [(123)I]iodobenzamide (IBZM) were used for in vivo imaging. Subjects commenced reading or writing immediately before IBZM injection and continued for 30min thereafter. SPECT images were acquired 60min later. Striatum-to-parietal-cortex IBZM uptake ratios were lower in subjects who wrote off the text than in controls indicating competition of IBZM and dopamine. There was no difference between subjects who read the text and controls. Thus, dopamine release occurs as a consequence of the motoric activity involved in writing rather than of cognitive functions necessary for reading the text.

  18. Therapeutic effect of co-enzyme Q10 on idiopathic dilated cardiomyopathy: assessment by iodine-123 labelled 15-(p-iodophenyl)-3(R,S)-methylpentadecanoic acid myocardial single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong-ih [Department of Internal Medicine, Nishiyodo Hospital, Nishiyodo (Japan); Sawada, Yoshihiro [Department of Internal Medicine, Nishiyodo Hospital, Nishiyodo (Japan); Fujiwara, Go [Department of Radiology, Nishiyodo Hospital, Nishiyodo (Japan); Chiba, Hiroshi [Department of Internal Medicine, Mimihara General Hospital, Mimihara (Japan); Nishimura, Tsunehiko [Division of Tracer Kinetics, Biomedical Research Center, Osaka University Medical School, Osaka (Japan)

    1997-06-10

    It has been reported that myocardial mitochondrial function can be improved by the administration of co-enzyme Q10 (CoQ10). Recently, iodine-123 labelled 15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (BMIPP) was developed for metabolic imaging using single-photon emission tomography (SPET). This study was conducted to determine whether the therapeutic effects of CoQ10 on idiopathic dilated cardiomyopathy can be evaluated by BMIPP myocardial SPET. Fifteen patients, comprising 14 men and one woman (mean age: 64{+-}12 years), were examined. CoQ10 was administered at 30 mg/day for a period of 35.7{+-}12.4 days. BMIPP myocardial SPET was carried out before and after CoQ10 treatment. The count ratio of the heart (H) to the upper mediastinum (M) (H/M ratio) was calculated using a region of interest method with anterior planar imaging. Representative short-axis tomograms were divided into 27 segments (three slices x nine segments). Each segmental score was analysed semiquantitatively using a four-point scoring system (normal=0, mild low uptake=1, severe low uptake=2, defect=3). The H/M ratio showed a significant improvement, from 2.39{+-}0.39 to 2.54{+-}0.47, after treatment (P<0.05). The BMIPP total defect score after CoQ10 treatment was significantly decreased to 10.1{+-}4.3, compared to 13.9{+-}4.5 without CoQ10 treatment (P<0.001). However, the percent fractional shortening measured using echocardiography was not significantly different before and after CoQ treatment (19.2{+-}8.1 vs 19.7{+-}7.1). BMIPP myocardial SPET was confirmed to be sensitive in evaluating the therapeutic effects of CoQ10 in patients with idiopathic dilated cardiomyopathy. This method is unique, since the therapeutic effects can be estimated from the perspective of metabolic SPET imaging. (orig.). With 5 figs., 1 tab.

  19. Industrial system for producing iodine-123

    International Nuclear Information System (INIS)

    Brantley, J.C.

    1985-01-01

    An industrial system to produce iodine-123 required a complex set of steps involving new approaches by the Food and Drug Administration, difficult distribution procedures, and evidence from potential users that either very pure iodine-123 or inexpensive iodine-123 is needed. Industry has shown its willingness to invest in new radionuclides but needs strong evidence as to product potential to justify those investments

  20. Quantitative SPECT reconstruction of iodine-123 data

    International Nuclear Information System (INIS)

    Gilland, D.R.; Jaszczak, R.J.; Greer, K.L.; Coleman, R.E.

    1991-01-01

    Many clinical and research studies in nuclear medicine require quantitation of iodine-123 ( 123 I) distribution for the determination of kinetics or localization. The objective of this study was to implement several reconstruction methods designed for single-photon emission computed tomography (SPECT) using 123 I and to evaluate their performance in terms of quantitative accuracy, image artifacts, and noise. The methods consisted of four attenuation and scatter compensation schemes incorporated into both the filtered backprojection/Chang (FBP) and maximum likelihood-expectation maximization (ML-EM) reconstruction algorithms. The methods were evaluated on data acquired of a phantom containing a hot sphere of 123 I activity in a lower level background 123 I distribution and nonuniform density media. For both reconstruction algorithms, nonuniform attenuation compensation combined with either scatter subtraction or Metz filtering produced images that were quantitatively accurate to within 15% of the true value. The ML-EM algorithm demonstrated quantitative accuracy comparable to FBP and smaller relative noise magnitude for all compensation schemes

  1. Iodine-123 in Western Europe

    International Nuclear Information System (INIS)

    Qaim, S.M.; Stoecklin, G.; Weinreich, R.

    1976-08-01

    The major object of this panel was to obtain information on the state of art of Iodine-123 production in Western Europe. Technical, medical and organizational problems were discussed extensively during the one-day meeting and a stimulating exchange of information between the various 123 I-producers and users has been initiated. Some specific examples of medical application were also included in order to get a feeling of the degree of acceptance by the medical community and the demand for this isotope. The meeting clearly demonstrated the great demand for this isotope but it also showed that the present rate of production is well below the demand. In order to fill this gap, not only further technical development is needed but also the organizational question of distribution has to be solved, perhaps within a network of collaborating cyclotrons, a task which is considerably more difficult in Western Europe than in the USA. (orig./HP) [de

  2. Iodine-123 program at the TRIUMF laboratory

    International Nuclear Information System (INIS)

    Vincent, J.S.

    1985-01-01

    A research program for the production and utilization of iodine-123 is described. From 1979 to 1982 the spallation of elemental cesium by 500-MeV protons was used to provide 100 mCi/hr at the end of bombardment (EOB). Contaminants were 3% iodine-125 and 0.15% tellurium-121 at EOB + 36 hr. The material from weekly runs was used by remote clinics in Canada for evaluation as a radiochemical and for labeling studies. A new facility at TRIUMF will be operational in 1983 to produce iodine-123 by the (p,5n) reaction

  3. The development of iodine-123-methyl-branched fatty acids and their applications in nuclear cardiology

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Kropp, J.; Goodman, M.M.

    1993-01-01

    Continuous interest in the use of iodine-123-labeled fatty acids for myocardial imaging results from observations from a variety of studies that in many types of cardiac disease, regional fatty acid myocardial uptake patterns are often different than regional distribution of flow tracers. These differences may reflect alterations in important parameters of metabolism which can be useful for patient management or therapeutic strategy decision making. In addition, use of iodine-123-labeled fatty acid distribution may represent a unique metabolic probe to relate some aspects of the metabolism of these substrates with the regional viability of cardiac tissue. The use of such viability makers could provide important prognostic information on myocardial salvage, helping to identify patients for revascularization or angioplasty. Clinical studies are currently in progress with the iodine-123-labeled 15-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) fatty acid analogue at several institutions. The goals of this paper are to discuss development of the concept of metabolic trapping of fatty acids, to briefly review development and evaluation of various radioiodinated methyl-branched fatty acids and to discuss recent patient studies with iodine-123 (BMIPP) using single photon emission computerized tomography (SPECT). (author)

  4. The development of iodine-123-labeled-methyl-branched fatty acids for myocardial SPECT imaging

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Kropp, J.

    1994-01-01

    Iodine-123-labeled fatty acids represent unique metabolic probes for correlation of energy substrate metabolism with regional myocardial viability. Interest in the use of these agents results from differences which are often observed in various types of heart disease between regional myocardial fatty acid uptake patterns and flow tracer distribution. Although the physiological basis is not completely understood, differences between regional fatty acid and flow tracer distribution may reflect alterations in important parameters of metabolism which can be useful for patient management or therapeutic strategy decision making. The iodine-123-labeled 15-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) fatty acid analogue was developed at the Oak Ridge National Laboratory and was recently introduced as ''Cardiodine trademark'' in 1993 by Nihon Medi-Physics for commercial distribution in Japan. Iodine-123-BMPP is also being used in clinical studies on an institutional approval basis at several institutions in Europe and the US. This paper describes the development of the concept of fatty acid ''metabolic trapping'' of methyl-branched fatty acids and their use for single photon emission computerized tomographic cardiac imaging

  5. Development of radioiodinated receptor ligands for cerebral single photon emission tomography

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; McPherson, D.W.

    1992-01-01

    In the last decade the use of radiolabeled ligands for the imaging of cerebral receptors by emission computed tomography (ECT) has seen rapid growth. The opportunity to routinely perform cerebral single photon emission tomography (SPET) with iodine-123-labeled ligands depends on the availability of receptor ligands into which iodine can be introduced without decreasing the required high target receptor specificity. The use of iodine-123-labeled receptor-specific ligands also depends on the availability of high purity iodine-123 at reasonable costs and the necessary imaging instrumentation. In this paper, the development and current stage of evaluation of various iodine-123-labeled ligands for SPET imaging of dopaminergic, serotonergic and muscarinic acetylcholinergic receptor classes are discussed

  6. The development of iodine-123-methyl-branched fatty acids and their applications in nuclear cardiology

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F. Jr.; Ambrose, K.R. [Oak Ridge National Lab., TN (United States); Kropp, J.; Biersack, H.J. [Bonn Univ. (Germany). Inst. fuer Klinische und Experimentelle Nuklearmedizin; Goodman, M.M. [University of Tennessee Medical Center, Knoxville, TN (United States). Dept. of Radiology; Franken, P. [Free Univ. Hospital, Brussels (Belgium). Nuclear Medicine Dept.; Reske, S.N. [Ulm Univ. (Germany). Sektion Nuklearmedizin; Som, P. [Brookhaven National Lab., Upton, NY (United States); Sloof, G.W.; Visser, F.C. [Free Univ. Hospital, Amsterdam (Netherlands). Cardiology Dept.

    1993-06-01

    Continued Interest in the use of iodine-1 23-labeled fatty acids for myocardial Imaging results from observations from a variety of studies that in many types of cardiac disease, regional fatty acid myocardial uptake patterns are often different than regional distribution of flow tracers. These differences may reflect alterations in important parameters of metabolism which can be useful for patient management or therapeutic strategy decision making. In addition, use of iodine-I 23-labeled fatty acid distribution may represent a unique metabolic probe to relate some aspects of the metabolism of these substrates with the regional viability of cardiac tissue. The use of such viability markers could provide important prognostic information on myocardial salvage, helping to identify patients for revascularization or angioplasty. Clinical studies are currently in progress with the iodine-123-labeled 1 5-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) fatty acid analogue at several institutions. The goals of this paper are to discuss development of the concept of metabolic trapping of fatty acids, to briefly review development and evaluation of various radioiodinated methyl-branched fatty acids and to discuss recent patient studies with iodine-123 (BMIPP) using single photon emission computerized tomography (SPECT).

  7. The development of iodine-123-methyl-branched fatty acids and their applications in nuclear cardiology

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F. Jr.; Ambrose, K.R. (Oak Ridge National Lab., TN (United States)); Kropp, J.; Biersack, H.J. (Bonn Univ. (Germany). Inst. fuer Klinische und Experimentelle Nuklearmedizin); Goodman, M.M. (University of Tennessee Medical Center, Knoxville, TN (United States). Dept. of Radiology); Franken, P. (Free Univ. Hospital, Brussels (Belgium). Nuclear Medicine Dept.); Reske, S.N. (Ulm Univ. (Germany

    1993-01-01

    Continued Interest in the use of iodine-1 23-labeled fatty acids for myocardial Imaging results from observations from a variety of studies that in many types of cardiac disease, regional fatty acid myocardial uptake patterns are often different than regional distribution of flow tracers. These differences may reflect alterations in important parameters of metabolism which can be useful for patient management or therapeutic strategy decision making. In addition, use of iodine-I 23-labeled fatty acid distribution may represent a unique metabolic probe to relate some aspects of the metabolism of these substrates with the regional viability of cardiac tissue. The use of such viability markers could provide important prognostic information on myocardial salvage, helping to identify patients for revascularization or angioplasty. Clinical studies are currently in progress with the iodine-123-labeled 1 5-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) fatty acid analogue at several institutions. The goals of this paper are to discuss development of the concept of metabolic trapping of fatty acids, to briefly review development and evaluation of various radioiodinated methyl-branched fatty acids and to discuss recent patient studies with iodine-123 (BMIPP) using single photon emission computerized tomography (SPECT).

  8. Automatic segmentation of dynamic neuroreceptor single-photon emission tomography images using fuzzy clustering

    International Nuclear Information System (INIS)

    Acton, P.D.; Pilowsky, L.S.; Kung, H.F.; Ell, P.J.

    1999-01-01

    The segmentation of medical images is one of the most important steps in the analysis and quantification of imaging data. However, partial volume artefacts make accurate tissue boundary definition difficult, particularly for images with lower resolution commonly used in nuclear medicine. In single-photon emission tomography (SPET) neuroreceptor studies, areas of specific binding are usually delineated by manually drawing regions of interest (ROIs), a time-consuming and subjective process. This paper applies the technique of fuzzy c-means clustering (FCM) to automatically segment dynamic neuroreceptor SPET images. Fuzzy clustering was tested using a realistic, computer-generated, dynamic SPET phantom derived from segmenting an MR image of an anthropomorphic brain phantom. Also, the utility of applying FCM to real clinical data was assessed by comparison against conventional ROI analysis of iodine-123 iodobenzamide (IBZM) binding to dopamine D 2 /D 3 receptors in the brains of humans. In addition, a further test of the methodology was assessed by applying FCM segmentation to [ 123 I]IDAM images (5-iodo-2-[[2-2-[(dimethylamino)methyl]phenyl]thio] benzyl alcohol) of serotonin transporters in non-human primates. In the simulated dynamic SPET phantom, over a wide range of counts and ratios of specific binding to background, FCM correlated very strongly with the true counts (correlation coefficient r 2 >0.99, P 123 I]IBZM data comparable with manual ROI analysis, with the binding ratios derived from both methods significantly correlated (r 2 =0.83, P<0.0001). Fuzzy clustering is a powerful tool for the automatic, unsupervised segmentation of dynamic neuroreceptor SPET images. Where other automated techniques fail completely, and manual ROI definition would be highly subjective, FCM is capable of segmenting noisy images in a robust and repeatable manner. (orig.)

  9. Reduced cortical distribution volume of iodine-123 iomazenil in Alzheimer's disease as a measure of loss of synapses

    DEFF Research Database (Denmark)

    Soricelli, A; Postiglione, A; Grivet-Fojaja, M R

    1996-01-01

    indiscriminately to affect all cortical neurons, albeit more so in some areas than in others. In this pilot study we measured Vd in six patients with probable AD and in five age-matched controls using a brain-dedicated single-photon emission tomography scanner allowing all cortical levels to be sampled......Iodine-123 labelled iomazenil (IMZ) is a specific tracer for the GABAA receptor, the dominant inhibitory synapse of the brain. The cerebral distribution volume (Vd) of IMZ may be taken as a quantitative measure of these synapses in Alzheimer's disease (AD), where synaptic loss tends...

  10. Gas-target method for the production of iodine-123

    International Nuclear Information System (INIS)

    Robertson, R.; Stuart, D.C.

    1986-01-01

    The object of this invention is to provide a means of producing iodine-123 in high yield and purity via a small accelerator. The process uses protons of about 30 MeV incident upon a target of isotopically-enriched xenon-124 gas. The product obtained has a useful life after preparation of at least 85 hours

  11. An economical method for the continuous production of iodine-123

    Science.gov (United States)

    Blue, J. W.; Smith, W. R.; Sodd, V. J.

    1968-01-01

    Simple and inexpensive method produces iodine 123, in a conventional cyclotron. Tellurium 122, a stable isotope available in enrichments exceeding 95 percent, is held on a porous metal plate by a flowing stream of helium and bombarded with either alpha particles or helium 3.

  12. Labeling of indocyanine green with carrier-free iodine-123

    International Nuclear Information System (INIS)

    Ansari, A.N.; Lambrecht, R.M.; Redvanly, C.S.; Wolf, A.P.

    1976-01-01

    The method is described for labeling indocyanine green (ICG) with carrier-free iodine-123 by condensing xenon-123 on crystals of ICG followed by permitting decay of the 123 Xe a sufficient length of time to produce 123 I-electronically excited ions and atoms which subsequently label ICG. 4 claims, no drawings

  13. Medical necessity for shorter lived radionuclides, specifically pure Iodine-123

    International Nuclear Information System (INIS)

    DeNardo, G.L.; DeNardo, S.J.; Hines, H.H.; Lagunas-Solar, M.C.; Jungerman, J.A.

    1985-01-01

    Iodine-123 has physical and radiochemical characteristics ideal for most tracer procedures performed in patients. Its use is generally preferable to the use of 131 I for diagnosis. The potential for 123 I can be realized only if a radiopharmaceutical of lesser radionuclide contamination is generally and economically available. Iodine-123 produced by direct methods has significant disadvantages relative to quality of procedure and radiation dosimetry. Our experience with 123 I(p,5n) during the past 12 years causes us to vigorously encourage general availability of an 123 I radiopharmaceutical of this quality. Using this product, the authors have prepared radiopharmaceuticals for use in the study of cancer, coagulation, and renal and thyroid diseases

  14. Diagnosis of dementia with single photon emission computed tomography

    International Nuclear Information System (INIS)

    Jagust, W.J.; Budinger, T.F.; Reed, B.R.

    1987-01-01

    Single photon emission computed tomography is a practical modality for the study of physiologic cerebral activity in vivo. We utilized single photon emission computed tomography and N-isopropyl-p-iodoamphetamine iodine 123 to evaluate regional cerebral blood flow in nine patients with Alzheimer's disease (AD), five healthy elderly control subjects, and two patients with multi-infarct dementia. We found that all subjects with AD demonstrated flow deficits in temporoparietal cortex bilaterally, and that the ratio of activity in bilateral temporoparietal cortex to activity in the whole slice allowed the differentiation of all patients with AD from both the controls and from the patients with multi-infarct dementia. Furthermore, this ratio showed a strong correlation with disease severity in the AD group. Single photon emission computed tomography appears to be useful in the differential diagnosis of dementia and reflects clinical features of the disease

  15. Iodine 123-antipyrine. A diffusible tracer for brain exploration

    International Nuclear Information System (INIS)

    Dantonel-Mathieu, Evelyne.

    1978-09-01

    Iodine 123-labelled iodoantipyrine is a liposoluble diffusible tracer which crosses the blood-brain barrier intact. Its build-up in brain tissue is proportional to the regional blood flow. Its behavior was studied in undervascularised brain lesions and in cases where research with traditional radioactive tracers (99mTc and its different vectors for example) has proved limited. Because of the great diffusibility of iodoantipyrine a brain parenchyma image is obtained within minutes after its injection, and this by the use of a non-invasive technique and under good gamma-camera exploration conditions. 81 brain explorations including 11 standards have been carried out on subjects averaging 51,2 years old; these examinations took place in three nuclear medicine centres. The 123 I iodoantipyrine used in each nuclear medicine centre is supplied by the CEA. Iodoantipyrine is labelled with a good yield (>98%) checked by chromatography by means of a CEA kit. After intraveinous injection of 4 to 6 mCi iodine-123 iodoantipyrine, a dynamic study (from 0 to 60 seconds) of the tracer passage in the brain tissue may be followed by static images taken in the next minutes according to a standard procedure. The table of results shows the major interest of this tracer for the exploration of vascular accidents with ischemic lesions, especially in the early phase of the accident. The lesion appears as a hypoactive zone and this lack of perfusion lasts for some minutes after the injection [fr

  16. Dosimetry of iodine-123 for newborn and infant

    International Nuclear Information System (INIS)

    Guilhem, M.T.; Therain, F.

    1987-01-01

    Iodine-123 ( 123 I) is a radionuclide of choice of neonatal hypothyroidism diagnosis. It is important to know infant main organs adsorbed doses during a thyroid scan with 123 I. Absorbed doses are already available for adults: for infants, they must be transformed taking account of organs sizes and inter-organs distances. Calculations are done for commercially available 123 I(p,2n) and 123 I(p,5n). Important contamination of 124 I in 123 I(p,2n) increases considerably the absorbed-dose during thyroid scan of a newborn (the ratio 124 I/ 123 I doubles every 15h). For routinely used activities, thyroid absorbed dose, 24 h after end of production, is fifteen times higher with 123 I(p,5n) than with 99m Tc: for one month old child; total body absorbed dose is of the same order of magnitude [fr

  17. Iodine-123 metaiodobenzylguanidine in the assessment of late cardiac effects from cancer therapy

    International Nuclear Information System (INIS)

    Valdes Olmos, R.A.; Bokkel Huinink, W.W. ten; Dewit, L.G.H.; Hoefnagel, C.A.; Liem, I.H.; Tinteren, H. van

    1996-01-01

    Recognition of adverse late cardiac effects from cancer therapy may enable identification of patients with risk of cardiotoxicity upon cancer retreatment. In this study the feasibility of using iodine-123 metaiodobenzylguanidine ( 123 I-MIBG) heart scintigraphy to detect abnormalities of the myocardial adrenergic neurone function in the late period after cancer therapy was evaluated in relation to the left ventricle ejection fraction (LVEF) in 18 cancer patients: 11 had undergone thoracic irradiation involving the heart, in five cases in combination with anthracycline therapy, 11-228 months (median 60 months) before radionuclide tests, while seven had not received previous anthracycline and/or radiotherapy (controls). The 123 I-MIBG cardiac uptake, expressed as a heart-to-mediastinum ratio on planar images after 4 h, ranged from 1.21 to 1.76 (median 1.56) in cancer therapy patients, which was significantly decreased (P=0.0006) in comparison with controls (range 1.81-2.06, median 1.9). The myocardial 123 I-MIBG washout, calculated from planar images after 15 min and 4 h, and LVEF also showed significant differences, but with some overlap in individual cases. In cancer therapy patients, cardiac abnormalities seen on planar images and additional single-photon emission tomographic images varied from focal defects to diffusely reduced myocardial uptake. It is concluded that 123 I-MIBG heart scintigraphy, which is able to identify cardiac adrenergic neurone abnormalities in the follow-up period after cancer therapy, may help to identify relapsed patients who are at increased risk of developing cardiotoxicity during retreatment with cardiotoxic therapy modalities. (orig.). With 4 figs., 2 tabs

  18. Uptake of iodine-123-α-methyl tyrosine by gliomas and non-neoplastic brain lesions

    International Nuclear Information System (INIS)

    Kuwert, T.; Morgenroth, C.; Woesler, B.; Matheja, P.; Palkovic, S.; Vollet, B.; Samnick, S.; Maasjosthusmann, U.; Lerch, H.; Gildehaus, F.J.; Wassmann, H.; Schober, O.

    1996-01-01

    Using single-photon emission tomography (SPET), the radiopharmaceutical L-3-iodine-123-α-methyl tyrosine (IMT) has been applied to the imaging of amino acid transport into brain tumours. It was the aim of this study to investigate whether IMT SPET is capable of differentiating between high-grade gliomas, low-grade gliomas and non-neoplastic brain lesions. To this end, IMT uptake was determined in 53 patients using the triple-headed SPET camera MULTISPECT 3. Twenty-eight of these subjects suffered from high-grade gliomas (WHO grade III or IV), 12 from low-grade gliomas (WHO grade II), and 13 from non-neoplastic brain lesions, including lesions after effective therapy of a glioma (five cases), infarctions (four cases), inflammatory lesions (three cases), infarctions (four cases), inflammatory lesions (three cases) and traumatic haematoma (one case). IMT uptake was significantly higher in high-grade gliomas than in low-grade gliomas and non-neoplastic lesions. IMT uptake by low-grade gliomas was not significantly different from that by non-neoplastic lesions. Diagnostic sensitivity and specificity were 71% and 83% for differentiating high-grade from low-grade gliomas, 82% and 100% for distinguishing high-grade gliomas from non-neoplastic lesions, and 50% and 100% for discriminating low-grade gliomas from non-neoplastic lesions. Analogously to positron emission tomography with radioactively labelled amino acids and fluorine-18 deoxyglucose, IMT SPET may aid in differentiating higc-grade gliomas from histologically benign brain tumours and non-neoplastic brain lesions; it is of only limited value in differentiating between non-neoplastic lesions and histologically benign brain tumours. (orig.)

  19. Single-photon imaging

    CERN Document Server

    Seitz, Peter

    2011-01-01

    The acquisition and interpretation of images is a central capability in almost all scientific and technological domains. In particular, the acquisition of electromagnetic radiation, in the form of visible light, UV, infrared, X-ray, etc. is of enormous practical importance. The ultimate sensitivity in electronic imaging is the detection of individual photons. With this book, the first comprehensive review of all aspects of single-photon electronic imaging has been created. Topics include theoretical basics, semiconductor fabrication, single-photon detection principles, imager design and applications of different spectral domains. Today, the solid-state fabrication capabilities for several types of image sensors has advanced to a point, where uncoooled single-photon electronic imaging will soon become a consumer product. This book is giving a specialist´s view from different domains to the forthcoming “single-photon imaging” revolution. The various aspects of single-photon imaging are treated by internati...

  20. Iodine-123-labelled serum amyloid P component scintigraphy in amyloidosis

    International Nuclear Information System (INIS)

    Saile, R.; Deveaux, M.; Marchandise, X.; Duquesnoy, B.

    1993-01-01

    This study describes the results of scintigraphy with iodine-123-labelled serum amyloid P component (SAP) as a means of establishing the distribution of organ involvement in amyloidosis. The significance of 123 I-SAP scans obtained in 15 patients with biopsy-proven AA or AL amyloidosis is discussed. Biopsy-proven amyloidosis was typically confirmed by scintigraphy, though such confirmation was not obtained in the kidneys in six patients with histological proof of extensive renal amyloid deposition. This lack of uptake may have been due to the accumulation of a major part of the 123 I-SAP in the spleen and/or liver. Twenty-four hour whole-body retention of 123 I-SAP was higher in patients with amyloidosis than in controls. Twenty-four hour tracer accumulation of the radioactivity in the extravascular compartment was notably greater in patients than in controls and appeared to be a good diagnostic criterion. We conclude that 123 I-SAP scintigraphy may be helpful for the evaluation of organ involvement not only in patients with biopsy-proven amyloidosis but also when a biopsy cannot be performed or when a strong suspicion of amyloidosis exists in spite of repeated negative biopsises. (orig.)

  1. Single photon ECT

    International Nuclear Information System (INIS)

    Maeda, Toshio; Matsuda, Hiroshi; Tada, Akira; Bunko, Hisashi; Koizumi, Kiyoshi

    1982-01-01

    The detectability of lesions located deep in a body or overlapped with a physiologically increased activity improve with the help of single photon ECT. In some cases, the ECT is superior to the conventional gamma camera images and X-ray CT scans in the evaluation of the location and size of lesion. The single photon ECT of the brain compares favorably with the contrast enhansed X-ray CT scans. The most important adaptation of the single photon ECT are the detection of recurrent brain tumors after craniotomy and the evaluation of ischemic heart diseases. (author)

  2. Single-Photon Optomechanics

    Science.gov (United States)

    Nunnenkamp, A.; Børkje, K.; Girvin, S. M.

    2011-08-01

    Optomechanics experiments are rapidly approaching the regime where the radiation pressure of a single photon displaces the mechanical oscillator by more than its zero-point uncertainty. We show that in this limit the power spectrum has multiple sidebands and that the cavity response has several resonances in the resolved-sideband limit. Using master-equation simulations, we also study the crossover from the weak-coupling many-photon to the single-photon strong-coupling regime. Finally, we find non-Gaussian steady states of the mechanical oscillator when multiphoton transitions are resonant. Our study provides the tools to detect and take advantage of this novel regime of optomechanics.

  3. Pharmacokinetics and dosimetry of iodine-123 labelled PE2I in humans, a radioligand for dopamine transporter imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J.T.; Bergstroem, K.A.; Yu, Meixiang; Laitinen, T. [Department of Clinical Physiology, Kuopio University Hospital, FIN-70210 Kuopio (Finland); Baulieu, J.L.; Emond, P.; Chalon, S.; Guilloteau, D. [Laboratoire de Biophysique Medicale et Pharmaceutique, Universite Francois Rabelais, F-37200 Tours (France); Hiltunen, J.; Nikula, T. [MAP Medical Technologies Oy, FIN-41160 Tikkakoski (Finland); Halldin, C.; Farde, L. [Karolinska Institute, Department of Clinical Neuroscience, Psychiatry Section, Karolinska Hospital, S-17 176 Stockholm (Sweden); Karhu, J. [Department of Clinical Neurophysiology, Kuopio University Hospital, FIN-70210 Kuopio (Finland); Tupala, E.; Hallikainen, T.; Tiihonen, J. [Department of Forensic Psychiatry, Niuvanniemi Hospital, FIN-70240 Kuopio (Finland); Kolehmainen, V. [Department of Applied Physics, University of Kuopio, FIN-70210 Kuopio (Finland); Mauclaire, L. [CIS bio international, F-91192 Gif-sur-Yvette (France); Maziere, B. [Service Hospitalier Frederic Joliot, CEA, F-91406 Orsay (France)

    1998-05-01

    The iodine-123 labelled selective ligand N-(3-iodoprop-2E-enyl)-2-{beta}-carbomethoxy-3{beta}-(4-methylphenyl)nortropane ([{sup 123}I]PE2I) was evaluated as a probe for in vivo dopamine transporter imaging in the human brain. Six healthy subjects were imaged with a high-resolution single-photon emission tomography scanner. Striatal radioactivity peaked at 1 h after injection. The background radioactivity was low. The volume of distribution in the striatum was 94{+-}24 ml/ml. The results were compared with those of [{sup 123}I]{beta}-CIT imaging. There was no significant uptake of [{sup 123}I]PE2I in serotonin-rich regions such as the midbrain, hypothalamus and anterior gingulus, suggesting that in vivo binding is specific for the dopamine transporter. One main polar metabolite of [{sup 123}I]PE2I was found in plasma, and the parent plasma concentration decayed rapidly. Radiation exposure to the study subject is 0.022{+-}0.004 mSv/MBq (effective dose). The preliminary results suggest that [{sup 123}I]PE2I is a selective SPET ligand for imaging striatal dopamine transporter density. (orig.) With 4 figs., 11 refs.

  4. Pharmacokinetics and dosimetry of iodine-123 labelled PE2I in humans, a radioligand for dopamine transporter imaging

    International Nuclear Information System (INIS)

    Kuikka, J.T.; Bergstroem, K.A.; Yu, Meixiang; Laitinen, T.; Baulieu, J.L.; Emond, P.; Chalon, S.; Guilloteau, D.; Hiltunen, J.; Nikula, T.; Halldin, C.; Farde, L.; Karhu, J.; Tupala, E.; Hallikainen, T.; Tiihonen, J.; Kolehmainen, V.; Mauclaire, L.; Maziere, B.

    1998-01-01

    The iodine-123 labelled selective ligand N-(3-iodoprop-2E-enyl)-2-β-carbomethoxy-3β-(4-methylphenyl)nortropane ([ 123 I]PE2I) was evaluated as a probe for in vivo dopamine transporter imaging in the human brain. Six healthy subjects were imaged with a high-resolution single-photon emission tomography scanner. Striatal radioactivity peaked at 1 h after injection. The background radioactivity was low. The volume of distribution in the striatum was 94±24 ml/ml. The results were compared with those of [ 123 I]β-CIT imaging. There was no significant uptake of [ 123 I]PE2I in serotonin-rich regions such as the midbrain, hypothalamus and anterior gingulus, suggesting that in vivo binding is specific for the dopamine transporter. One main polar metabolite of [ 123 I]PE2I was found in plasma, and the parent plasma concentration decayed rapidly. Radiation exposure to the study subject is 0.022±0.004 mSv/MBq (effective dose). The preliminary results suggest that [ 123 I]PE2I is a selective SPET ligand for imaging striatal dopamine transporter density. (orig.)

  5. Quantitative iodine-123 IMP imaging of brain perfusion in schizophrenia

    International Nuclear Information System (INIS)

    Cohen, M.B.; Lake, R.R.; Graham, L.S.

    1989-01-01

    Decreased perfusion in the frontal lobes of patients with chronic schizophrenia has been reported by multiple observes using a variety of techniques. Other observers have been unable to confirm this finding using similar techniques. In this study quantitative single photon emission computed tomography brain imaging was performed using p,5n [ 123 I]IMP in five normal subjects and ten chronically medicated patients with schizophrenia. The acquisition data were preprocessed with an image dependent Metz filter and reconstructed using a ramp filtered back projection technique. The uptake in each of 50 regions of interest in each subject was normalized to the uptake in the cerebellum. There were no significant confirmed differences in the comparable ratios of normal subjects and patients with schizophrenia even at the p = 0.15 level. Hypofrontality was not observed

  6. Single photons on demand

    International Nuclear Information System (INIS)

    Grangier, P.; Abram, I.

    2004-01-01

    Quantum cryptography and information processing are set to benefit from developments in novel light sources that can emit photons one by one. Quantum mechanics has gained a reputation for making counter-intuitive predictions. But we rarely get the chance to witness these effects directly because, being humans, we are simply too big. Take light, for example. The light sources that are familiar to us, such as those used in lighting and imaging or in CD and DVD players, are so huge that they emit billions and billions of photons. But what if there was a light source that emitted just one photon at a time? Over the past few years, new types of light source that are able to emit photons one by one have been emerging from laboratories around the world. Pulses of light composed of a single photon correspond to power flows in the femtowatt range - a million billion times less than that of a table lamp. The driving force behind the development of these single-photon sources is a range of novel applications that take advantage of the quantum nature of light. Quantum states of superposed and entangled photons could lead the way to guaranteed-secure communication, to information processing with unprecedented speed and efficiency, and to new schemes for quantum teleportation. (U.K.)

  7. Evaluation of cardiac autonomic nerves by iodine-123 metaiodobenzylguanidine scintigraphy and ambulatory electrocardiography in patients after arterial switch operations

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Hajime; Maeda, Masanobu; Miyahara, Ken [Shakaihoken Chukyo Hospital, Nagoya (Japan)] [and others

    2000-05-01

    The autonomic cardiac nerves reach the heart after passing through the vicinity of the aortic root and the pulmonary trunk. The arterial switch operation (ASO) completely transects the ascending aorta and the pulmonary trunk. Therefore, this surgical procedure virtually denerves the heart. Cardiac sympathetic denervation and reinnervation were evaluated in patients after ASO using iodine-123 metaiodobenzylguanidine (MIBG) myocardial scintigraphy and parasympathetic denervation and reinnervation using ambulatory electrocardiography [Holter electrocardiogram (ECG)]. MIBG scintigraphy was performed in 14 patients who underwent ASO (ASO group) and 3 patients who underwent other open heart surgery (control group). All patients in the ASO group underwent the operation in the neonatal or infantile period. Planar and single photon emission computed tomography (SPECT) images of the myocardium were obtained. Defect score was determined by the SPECT images as a semi-quantitative index. The mean interval between ASO and MIBG scintigraphy was 25.6{+-}14.6 months. Holter ECG was also performed in 14 patients in the ASO group and 19 age-matched normal children. The Holter ECGs were plotted on a Lorenz plot. The H index, which is related to vagal tone for the cardiovascular system, was calculated from the R-R intervals. The mean interval between the ASO and Holter ECG was 8.3{+-}9.7 months. MIBG scintigraphy in the control group demonstrated an almost normal homogeneous tracer uptake, but showed extremely reduced tracer uptake and significantly higher defect score in the ASO group. The extent and degree of the reduction of MIBG uptake improved with time after the ASO. The heart-to-mediastinum MIBG count ratio tended to increase with time. The H index of the ASO group was lower than that of normal children (<12 months: Control group 0.0280{+-}0.0068 vs ASO group 0.0219{+-}0.0083), and gradually increased with time (1-3 years: 0.0470{+-}0.0157 vs 0.0314{+-}0.0124). (author)

  8. Prognostic significance of myocardial imaging with iodine-123 beta-methyl-p-iodophenyl-pentadecanoic acid in patients with angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Hatano, Tsuguhisa; Chikamori, Taishiro; Kamada, Tatsuya; Morishima, Takayuki; Hida, Satoshi; Yanagisawa, Hidefumi; Iino, Hitoshi; Yamashina, Akira [Tokyo Medical Coll. (Japan)

    2001-09-01

    To assess the clinical significance of iodine-123 beta-methyl-p-iodophenyl-pentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT), the predictive value of BMIPP imaging in patients with angina pectoris was evaluated. One hundred seventy-four patients who underwent BMIPP imaging in our institution were aged 61.8{+-}11 years. One hundred thirty-five patients had stable angina and 39 had unstable angina at the time of examination. Patients with previous myocardial infarction or myocardial disorders were excluded. Early and delayed images were acquired in BMIPP SPECT, and the images were analyzed visually. Cardiac events were classified into hard and soft events: the former consisted of cardiac death and nonfatal myocardial infarction, and the latter included coronary revascularization and heart failure. The findings of BMIPP imaging were normal in 82 patients and abnormal in 92. During follow-up of 15.5{+-}9.5 months, hard events were observed in 4 patients and soft events in 53. In patients with normal BMIPP imaging, soft events were observed in nine patients, but no hard event was encountered. Furthermore, in patients with both normal BMIPP and stress thallium imagings, no cardiac event was observed during 2 years. In contrast, 4 hard events and 44 soft events occurred in patients with abnormal BMIPP imaging. Patients with abnormal BMIPP imaging had a higher incidence of soft events than those with normal BMIPP imaging, regardless of the type of angina (16/62 vs 3/73, p<0.0005 for stable angina; 28/30 vs 6/9, p<0.0001 for unstable angina). The finding of BMIPP imaging correlates well with the mid-term prognosis of patients with angina pectoris. Since BMIPP SPECT is performed without stress to the patient, this imaging modality is important in evaluating patients with stable or unstable angina. (author)

  9. A method to quantitate cerebral blood flow using a rotating gamma camera and iodine-123 iodoamphetamine with one blood sampling

    International Nuclear Information System (INIS)

    Iida, Hidehiro; Itoh, Hiroshi; Bloomfield, P.M.; Munaka, Masahiro; Higano, Shuichi; Murakami, Matsutaro; Inugami, Atsushi; Eberl, S.; Aizawa, Yasuo; Kanno, Iwao; Uemura, Kazuo

    1994-01-01

    A method has been developed to quantitate regional cerebral blood blow (rCBF) using iodine-123-labelled N-isopropyl-p-iodoamphetamine (IMP). This technique requires only two single-photon emission tomography (SPET) scans and one blood sample. Based on a two-compartment model, radioactivity concentrations in the brain for each scan time are calculated. A standard input function has been generated by combining the input functions from 12 independent studies prior to this work to avoid frequent arterial blood sampling, and one blood sample is taken at 10 min following IMP administration for calibration of the standard arterial input function. This calibration time was determined such that the integration of the first 40 min of the calibrated, combined input function agreed best with those from 12 individual input functions (the difference was 5.3% on average). This method was applied to eight subjects (two normals and six patients with cerebral infarction), and yielded rCBF values which agreed well with those obtained by a positron emission tomography H 2 15 O autoradiography method. This method was also found to provide rCBF values that were consistent with those obtained by the non-linear least squares fitting technique and those obtained by conventional microsphere model analysis. The optimum SPET scan times were found to be 40 and 180 min for the early and delayed scans, respectively. These scan times allow the use of a conventional rotating gamma camera for clinical purposes. V d values ranged between 10 and 40 ml/g depending on the pathological condition, thereby suggesting the importance of measuring V d for each ROI. In conclusion, optimization of the blood sampling time and the scanning time enabled quantitative measurement of rCBF with two SPET scans and one blood sample. (orig.)

  10. Nanodiamond Emitters of Single Photons

    Directory of Open Access Journals (Sweden)

    Vlasov I.I.

    2015-01-01

    Full Text Available Luminescence properties of single color centers were studied in nanodiamonds of different origin. It was found that single photon emitters could be realized even in molecularsized diamond (less than 2 nm capable of housing stable luminescent center “silicon-vacancy.” First results on incorporation of single-photon emitters based on luminescent nanodiamonds in plasmonic nanoantennas to enhance the photon count rate and directionality, diminish the fluorescence decay time, and provide polarization selectivity are presented.

  11. Quantitative renal cinescintigraphy with iodine-123 hippuran methodological aspects, kit for labeling of hippuran

    International Nuclear Information System (INIS)

    Mehdaoui, A.; Pecking, A.; Delorme, G.; Mathonnat, F.; Debaud, B.; Bardy, A.; Coornaert, S.; Merlin, L.; Vinot, J.M.; Desgrez, A.; Gambini, D.; Vernejoul, P. de.

    1981-08-01

    The development of an extemporaneous kit for the labeling of ortho-iodo-hippuric acid (Hippuran) with iodine 123 allows the performance of a routine quantitative renal cinescintigraphy providing in 20 minutes, and in an absolutely non-traumatic way, a very complete renal morphofunctional study including: a cortical renal scintigraphy, sequential scintigraphies of excretory tract, renal functional curves, tubular, global, and separate clearances for each kidney. This functional quantitative investigation method should take a preferential place in the routine renal balance. The methodology of the technique is explained and compared to classical methods for estimation of tubular, global and separate clearances [fr

  12. Iodine-123 and bromine-75 production and development program at Juelich

    International Nuclear Information System (INIS)

    Stoecklin, G.

    1985-01-01

    The iodine-123 and bromine-75 production and development program at the Nuclear Research Center in Juelich as of 1982 is described, and examples of recent 123 I- and 75 Br-analogue tracers that have been developed to the level of clinical trial are given. Iodine-123 is produced via the 127 I(d,6n) 123 Xe → 123 I process and by the 124 Te(p,2n) 123 I and 122 Te(d,n) 123 I reactions. These production methods are critically reviewed. Bromine-75-labeled benzodiazenes have been prepared for in vivo mapping of benzodiazepine receptor sites. The 7-( 75 Br)-5-(2-fluorophenyl)-1-methyl-1,3-dihydro-2H-1,4-benzodiazepine-2-one (BFB) was prepared with a specific activity of > 10 4 Ci/mmole. Finally, preparation and applications of the halogenated amino acid L-3-( 123 I)-iodo-α-methyltyrosine (IMT) and the analogous 75 Br compound (BMT) are reported. Both IMT and BMT have been successfully applied for pancreas imaging and tomography, and IMT has been used for imaging both melanotic and amelanotic malignant melanoma of the eye

  13. Radioiodinated N-(2-aminoethyl)-2-chloro-4-iodobenzamide

    International Nuclear Information System (INIS)

    Ohmomo, Yoshiro; Murakami, Katsuhiko; Tanaka, Chiaki; Hirata, Masahiko; Magata, Yasuhiro; Yokoyama, Akira.

    1994-01-01

    In developing monoamine oxidase (MAO)-B specific radioligands, N-(2-aminoethyl)-2-chloro-4-[ 125 I]iodobenzamide ([ 125 I]FIBA) was conveniently synthesized from its tributylstannyl precursor by an iododestannylation reaction using sodium [ 125 I]iodide and hydrogen peroxide with high radiochemical yield. The method should be applicable for labeling with 123 I, a suitable radioisotope for in vivo imaging with single photon emission computed tomography (SPECT). In vitro binding studies using mouse brain mitochondrial preparations showed that the specific binding of [ 125 I]FIBA was saturable and of high affinity. Calculated values for K D and B max were 201 nM and 9.5 pmol/mg protein, respectively. The [ 125 I]FIBA binding was effectively prevented by MAO-B specific inhibitors (l-deprenyl, Ro 16-6491, FIBA) or substrate (β-phenethylamine). However, MAO-A specific inhibitor (clorgyline) and substrate (serotonin) had no significant effect. After an intravenous injection into mice, [ 125 I]FIBA showed high brain uptake (1.64% dose/g at 15-30 min post injection) and long retention (1.11% dose/g at 120 min post injection) in the brain. Good brain-to-blood radioactivity ratios of 2.19 and 2.41 at 60 and 120 min after injection, respectively, were obtained. The in vitro binding data and in vivo characteristics suggested that [ 125 I]FIBA is potentially useful as a probe for biological studies including specific labeling of MAO-B in vivo as well as in vitro. Moreover, the 123 I-labeled counterpart, [ 123 I]FIBA, might be valuable for non-invasive imaging and mapping of MAO-B in the living brain with SPECT. (author)

  14. Single photon searches at PEP

    Energy Technology Data Exchange (ETDEWEB)

    Hollebeek, R.

    1985-12-01

    The MAC and ASP searches for events with a single photon and no other observed particles are reviewed. New results on the number of neutrino generations and limits on selection, photino, squark and gluino masses from the ASP experiment are presented.

  15. Single photon searches at PEP

    International Nuclear Information System (INIS)

    Hollebeek, R.

    1985-12-01

    The MAC and ASP searches for events with a single photon and no other observed particles are reviewed. New results on the number of neutrino generations and limits on selection, photino, squark and gluino masses from the ASP experiment are presented

  16. Biodistribution and dosimetry of iodine-123-labelled Z-MIVE: an oestrogen receptor radioligand for breast cancer imaging

    NARCIS (Netherlands)

    Rijks, L. J.; Busemann Sokole, E.; Stabin, M. G.; de Bruin, K.; Janssen, A. G.; van Royen, E. A.

    1998-01-01

    This study reports on the distribution and radiation dosimetry of iodine-123-labelled cis-11beta-methoxy-17alpha-iodovinyloestradiol (Z-[123I]MIVE), a promising radioligand for imaging of oestrogen receptors (ERs) in human breast cancer. Whole-body scans were performed up to 24 h after intravenous

  17. Imaging of estrogen receptors in primary and metastatic breast cancer patients with iodine-123-labeled Z-MIVE

    NARCIS (Netherlands)

    Rijks, L. J.; Bakker, P. J.; van Tienhoven, G.; Noorduyn, L. A.; Boer, G. J.; Rietbroek, R. C.; Taat, C. W.; Janssen, A. G.; Veenhof, C. H.; van Royen, E. A.

    1997-01-01

    PURPOSE: To evaluate the feasibility of noninvasive imaging of estrogen receptors (ERs) in primary and metastatic breast cancer with the iodine-123-labeled ER-specific ligand cis-11beta-methoxy-17alpha-iodovinylestradiol-17beta (Z-[123I]MIVE) using conventional nuclear medicine techniques. PATIENTS

  18. Technical meeting of project counterparts on 'Cyclotron production of Iodine-123'. Report

    International Nuclear Information System (INIS)

    2002-01-01

    Several cyclotron laboratory facilities are very much interested in the production of Iodine-123 for medical applications in view of its optimal physical and chemical properties. Some of these countries have in the past used the solid target technology based on utilization of enriched Tellurium targets and are currently involved in the development of enriched Xenon-124 gas targets to improved radionuclidic purity as required by the needs of modern nuclear medicine. With the purpose of discussing the advances in the later route of production and to foster mutual co-operation among the developing countries interested in this technology, a meeting was convened with the participation of scientists from Argentina, Brazil, Iran, Korea and Syria. A scientist from the United States was also invited as an expert to provide advise on particular aspects of the technology. This publication contains as an annex technical reports from the participating institutions. All of these reports have been separately indexed and provided with abstracts

  19. Assessment of cardiac sympathetic nerve activity in children with chronic heart failure using quantitative iodine-123 metaiodobenzylguanidine imaging

    International Nuclear Information System (INIS)

    Karasawa, Kensuke; Ayusawa, Mamoru; Noto, Nobutaka; Sumitomo, Naokata; Okada, Tomoo; Harada, Kensuke

    2000-01-01

    Cardiac sympathetic nerve activity in children with chronic heart failure was examined by quantitative iodine-123 metaiodobenzylguanidine (MIBG) myocardial imaging in 33 patients aged 7.5±6.1 years (range 0-18 years), including 8 with cardiomyopathy, 15 with congenital heart disease, 3 with anthracycrine cardiotoxicity, 3 with myocarditis, 3 with primary pulmonary hypertension and 1 with Pompe's disease. Anterior planar images were obtained 15 min and 3 hr after the injection of iodine-123 MIBG. The cardiac iodine-123 MIBG uptake was assessed as the heart to upper mediastinum uptake activity ratio of the delayed image (H/M) and the cardiac percentage washout rate (%WR). The severity of chronic heart failure was class I (no medication) in 8 patients, class II (no symptom with medication) in 9, class III (symptom even with medication) in 10 and class IV (late cardiac death) in 6. H/M was 2.33±0.22 in chronic heart failure class I, 2.50±0.34 in class II, 1.95±0.61 in class III, and 1.39±0.29 in class IV (p<0.05). %WR was 24.8±12.8% in chronic heart failure class I, 23.3±10.2% in class II, 49.2±24.5% in class III, and 66.3±26.5% in class IV (p<0.05). The low H/M and high %WR were proportionate to the severity of chronic heart failure. Cardiac iodine-123 MIBG showed cardiac adrenergic neuronal dysfunction in children with severe chronic heart failure. Quantitative iodine-123 MIBG myocardial imaging is clinically useful as a predictor of therapeutic outcome and mortality in children with chronic heart failure. (author)

  20. Demonstration of disturbed free fatty acid metabolism of myocardium in patients with non-insulin-dependent diabetes mellitus as measured with iodine-123-heptadecanoic acid

    International Nuclear Information System (INIS)

    Kuikka, J.T.; Mustonen, J.N.; Uusitupa, M.I.J.; Rautio, P.; Vanninen, E.; Laakso, M.; Laensimies, E.; Kuopio Central Hospital

    1991-01-01

    Myocardial free fatty acid metabolism and left ventricular function were evaluated in 15 middle-aged patients with non-insulin dependent diabetes mellitus (NIDDM) and in 8 healthy control subjects. The study subjects had no evidence of coronary heart disease on the basis of clinical history, exercise ECG or myocardial perfusion scintigraphy. During peak exercise, iodine-123 hepatadecanoic acid (HDA) was intravenously injected. Myocardial activity distribution of 123 I-HDA was measured 10, 30, and 50 min after exercise using single-photon emission tomography (SPET); and then further corrected by free 123 I-iodine. Venous blood samples were drawn for detecting the plasma activity of 123 I. The net extraction of 123 I-HDA into the myocardium was obtained by dividing the corrected tissue 123 I concentration by the integral of the plasma time activity curve. The net extraction was 0.40±0.06 min -1 (mean±SD) patients with NIDDM and 0.38±0.006 min -1 in control subjects (P>0.1), respectively. The faster elimination rate of 123 I-HDA was found in patients with NIDDM (0.029±0.008 min -1 ) than in control subjects (0.022±0.004 min - 1); P 123 I-HDA and the change of LVEF, as well as with exercise load (r=0.68; P<0.01). In conclusion, evidence of an increased fatty acid utilization and triglyceride synthesis rate was observed in the diabetic myocardium. (orig.)

  1. Time relative single-photon (photoelectron) method

    International Nuclear Information System (INIS)

    Luo Binqiao

    1988-01-01

    A single-photon (photoelectron) measuring system is designed. It researches various problems in single-photon (photoelectron) method. The electronic resolving time is less than 25 ps. The resolving time of single-photon (photoelectron) measuring system is 25 to 65 ps

  2. Quantification of Iodine-123-FP-CIT SPECT with a resolution-independent method

    International Nuclear Information System (INIS)

    Dobbeleir, A.A.; Ham, H.R.; Hambye, A.E.; Vervaet, A.M.

    2005-01-01

    Accurate quantification of small-sized objects by SPECT is hampered by the partial volume effect. The present work evaluates the magnitude of this phenomenon with Iodine- 123 in phantom studies, and presents a resolution- independent method to quantify striatal I-123 FP-CIT uptake in patients. At first five syringes with internal diameters varying between 9 and 29mm and an anthropomorphic striatal phantom were filled with known concentrations of Iodine-123 and imaged by SPECT using different collimators and radii of rotation. Data were processed with and without scatter correction. From the measured activities, calibration factors were calculated for each specific collimator. Then a resolution-independent method for FP-CIT quantification using large regions of interest was developed and validated in 34 human studies (controls and patients) acquired in 2 different hospitals, by comparing its results to those obtained by a semi- quantitative striatal-to-occipital analysis. Taking the injected activity and decay into account, the measured counts/volume could be converted into absolute tracer concentrations. For the fan-beam, high resolution and medium energy collimators, the measured maximum activity in comparison to the 29 mm-diameter syringe was respectively 38%, 16% and 9% for the 9 mm-diameter syringe and 82%, 80% and 30% for the 16 mm syringe, and not significantly modified after scatter correction. For the anthropomorphic phantom, the error in measurement in % of the true concentration ranged between 0.3-9.5% and was collimator dependent. Medium energy collimators yielded the most homogeneous results. In the human studies, inter- observer variability was 11.4% for the striatal-to-occipital ratio and 3.1% for the resolution-independent method, with correlation coefficients >0.8 between both. The resolution- independent method was 89%-sensitive and 100%-specific to separate the patients without and with abnormal FP-CIT uptake (accuracy: 94%). Also the

  3. Influence of drugs on myocardial iodine-123 metaiodobenzylguanidine uptake in rabbit myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, S.; Karanikas, G.; Rodrigues, M.; Sinzinger, H. [Dept. of Nuclear Medicine, University of Vienna (Austria)

    2000-03-01

    About 15 years ago, iodine-123 metaiodobenzylguanidine (MIBG) myocardial imaging was introduced for the evaluation of myocardial sympathetic nerve function. Two uptake mechanisms for MIBG have so far been identified: uptake type I, a saturable, energy-dependent mechanism, and uptake type II, a non-saturable, energy-independent mechanism. We incubated isolated rabbit myocardial tissue samples with{sup 123}I-MIBG in order to assess the uptake characteristics and the influence of varying incubation conditions. Furthermore, we examined the effects of several drugs and uptake inhibitors on the myocardial uptake of MIBG. The in vitro myocardial uptake of MIBG reached a steady plateau at 23.87%{+-}3.63% after 1 h, i.e. a concentration gradient of 10, in a thermo-independent manner within a concentration range from 1.5 to 1500 {mu}M. This indicates an unsaturable uptake process in the tested concentrations. Pre-incubation with the following drugs caused a significant inhibitory effect on myocardial MIBG uptake: haloperidol, levomepromazine, metoprolol, labetalol and clomipramine. According to our findings, the uptake mechanism seems to be an unspecific process, but the concentration gradient of 10 makes passive diffusion unlikely. Further studies with uptake-II-blocking substances as well as with isolated myocardial cells will be needed to clarify the nature of the myocardial MIBG uptake mechanism. (orig.)

  4. Iodine-123 iodobenzofuran (I-123 IBF) SPECT in patients with parkinsonism

    International Nuclear Information System (INIS)

    Nakabeppu, Yoshiaki; Nakajo, Masayuki; Mitsuda, Mitsuru; Tsuchimochi, Shinsaku; Tani, Atsushi; Osame, Mitsuhiro

    1999-01-01

    Iodine-123 benzofuran (I-123 IBF) is a dopaminergic antagonist which is suitable for SPECT imaging of D2 receptors. The purpose of this study is to evaluate the potential usefulness of semi-quantitative parameters obtained from brain SPECT data of I-123 IBF for differential diagnosis in patients with parkinsonism (PN). Subjects were 10 patients with PN: 2 patients with striato-nigral degeneration (SND), 5 patients with Parkinson's disease (PD), 2 patients with progressive supranuclear palsy (PSP) and one patient with olivo-ponto-cerebellar atrophy (OPCA). The data were acquired with a triple-head gamma camera at 2 hours after intravenous injection of 167 MBq of I-123 IBF. Transverse images were reconstructed by means of filtered backprojection, and attenuation correction was performed by Chang's method (μ=0.08). The basal ganglia-to-frontal cortex ratio (GFR) and the basal ganglia-to-occipital cortex ratio (GOR) on slices of 5 different thicknesses were calculated. The GFR and GOR were lower in the SND group than in the other disease groups in all slices with different thicknesses (7.2 mm, 14.4 mm, 21.6 mm, 28.8 mm and 43.2 mm). The semiquantitative parameters (GFR and GOR) obtained from brain SPECT data at 2 hours after intravenous injection of I-123 IBF may be useful for differential diagnosis in patients with PN. (author)

  5. Suppression by perchlorate of technetium-99m and iodine-123 secretion in milk of lactating goats

    International Nuclear Information System (INIS)

    Mountford, P.J.; Heap, R.B.; Hamon, M.; Fleet, I.R.; Coakley, A.J.

    1987-01-01

    Lactating goats were infused with either technetium-99m (/sup 99m/Tc) or iodine-123 ( 123 I) together with chlorine-36 ( 36 Cl) through an indwelling catheter previously placed in an external pudic mammary artery. The radioisotope infusions were repeated together with 100 mg of sodium perchlorate. There was a rapid transfer of /sup 99m/Tc and 123 I into milk, reaching a peak concentration 30 min after a 15-min infusion. The fractional secretion of /sup 99m/Tc and 123 I in milk was reduced by 70%-80% and 60%-66%, respectively, by perchlorate. The fractional secretion of 36 Cl was not affected by perchlorate, and the shape of the 36 Cl secretion curve differed from those of /sup 99m/Tc and 123 I, which were similar. It is probable, therefore, that the latter nuclides were secreted by a transport route different from that of chloride. Available data describing the secretion of /sup 99m/Tc in human milk after pertechnetate administration was reviewed, and it was concluded that perchlorate pretreatment significantly reduced the secretion of /sup 99m/Tc in human breast milk

  6. Iodine-123 iodobenzofuran (I-123 IBF) SPECT in patients with parkinsonism

    Energy Technology Data Exchange (ETDEWEB)

    Nakabeppu, Yoshiaki; Nakajo, Masayuki; Mitsuda, Mitsuru; Tsuchimochi, Shinsaku; Tani, Atsushi; Osame, Mitsuhiro [Kagoshima Univ. (Japan). Faculty of Medicine

    1999-12-01

    Iodine-123 benzofuran (I-123 IBF) is a dopaminergic antagonist which is suitable for SPECT imaging of D2 receptors. The purpose of this study is to evaluate the potential usefulness of semi-quantitative parameters obtained from brain SPECT data of I-123 IBF for differential diagnosis in patients with parkinsonism (PN). Subjects were 10 patients with PN: 2 patients with striato-nigral degeneration (SND), 5 patients with Parkinson's disease (PD), 2 patients with progressive supranuclear palsy (PSP) and one patient with olivo-ponto-cerebellar atrophy (OPCA). The data were acquired with a triple-head gamma camera at 2 hours after intravenous injection of 167 MBq of I-123 IBF. Transverse images were reconstructed by means of filtered backprojection, and attenuation correction was performed by Chang's method ({mu}=0.08). The basal ganglia-to-frontal cortex ratio (GFR) and the basal ganglia-to-occipital cortex ratio (GOR) on slices of 5 different thicknesses were calculated. The GFR and GOR were lower in the SND group than in the other disease groups in all slices with different thicknesses (7.2 mm, 14.4 mm, 21.6 mm, 28.8 mm and 43.2 mm). The semiquantitative parameters (GFR and GOR) obtained from brain SPECT data at 2 hours after intravenous injection of I-123 IBF may be useful for differential diagnosis in patients with PN. (author)

  7. Myocardial adrenergic nerve activity in valvular diseases assessed by iodine-123-metaiodobenzylguanidine myocardial scintigraphy

    International Nuclear Information System (INIS)

    Imamura, Yoshihiro; Fukuyama, Takaya

    1997-01-01

    Iodine-123-metaiodobenzylguanidine (MIBG) imaging was used to assess myocardial adrenergic nerve activity in patients with heart failure. MIBG planar images were obtained in 94 patients. The uptake of MIBG, calculated as the heart-to-mediastinum activity ratio in the immediate image (15 min), showed a significant decrease only in patients with severe heart failure due to cardiomyopathy, but was not changed in those with valvular diseases. Storage and release of MIBG, calculated as the percentage myocardial MIBG washout from 15 min to 4 hours after isotope injection, was substantially accelerated in both patients with cardiomyopathy and valvular diseases in proportion to the severity of heart failure. These data suggest that, in severe heart failure associated with cardiomyopathy, norepinephrine uptake is reduced. Also, myocardial adrenergic nerve activity is accelerated in proportion to the severity of heart failure independent of the underlying cause. MIBG images were analyzed in 20 patients with mitral stenosis with the same methods to clarify whether myocardial adrenergic nerve activity is different in patients with heart failure without left ventricular volume or pressure overload. Myocardial uptake of MIBG did not show any significant difference. The percentage myocardial MIBG washout was increased in patients with severe heart failure. The closest correlation was between myocardial washout and cardiac output. In heart failure due to mitral stenosis, myocardial adrenergic nerve activity is intensified. Decrease in cardiac output associated with mitral stenosis acts as a potent stimulus for this intensification. (author)

  8. Iodobenzamide SPET in neurological and psychiatric diseases: technical aspects and clinical impact; Tomoscintigraphie cerebrale a l`iodobenzamide en pathologie neuropsychiatrique: technique et pertinence clinique

    Energy Technology Data Exchange (ETDEWEB)

    Tranquart, F.; Prunier-Levillion, C.; Guilloteau, D.; Toffol, B. de; Autret, A.; Besnard, J.C.; Baulieu, J.L. [Hopital Bretonneau, 37 - Tours (France)

    1996-12-31

    Cerebral dopamine receptor assessment using single photon emission tomography (SPET) was recently accepted as a valuable method for a relative quantification of these receptors. We have performed 45 examinations using iodobenzamide (123-IBZM), which is a ligand for post-synaptic D2 receptors, in a variety of neurological or psychiatric diseases in which the dopaminergic system could be involved. The relative quantification of these D2 receptors was performed using different ratios with striatal, cerebellar and total tracer uptake. We observed a significant decrease in 123-IBZM striatal tracer uptake in Parkinson`s disease, supra-nuclear palsy, Alzheimer disease or Huntington disease, in comparison with control subjects (p<0.05). The present study indicates that 123-IBZM SPET could be easily performed in the different nuclear medicine departments and is useful in atypical Parkinson`s disease to access the diagnosis and drug efficacy. This could be of prognostic value in suspected or marked Huntington`s disease. (authors). 27 refs., 1 tab., 4 figs.

  9. Single photon emission computerized tomography

    International Nuclear Information System (INIS)

    Hooge, P. de.

    1983-01-01

    In this thesis two single-photon emission tomographic techniques are presented: (a) longitudinal tomography with a rotating slanting-hole collimator, and (b) transversal tomography with a rotating gamma camera. These methods overcome the disadvantages of conventional scintigraphy. Both detection systems and the image construction methods are explained and comparisons with conventional scintigraphy are drawn. One chapter is dedicated to the determination of system parameters like spatial resolution, contrast, detector uniformity, and size of the object, by phantom studies. In separate chapters the results are presented of detection of tumors and metastases in the liver and the liver hilus; skeletal diseases; various pathological aberrations of the brain; and myocardial perfusion. The possible use of these two ect's for other organs and body areas is discussed in the last chapter. (Auth.)

  10. Iodine-123 lodobenzamide imaging, MRI and apomorphine testing in the evaluation of patients with Parkinsonism

    International Nuclear Information System (INIS)

    Van der Schaaf, A.A.; Stell, R.; Groom, G.N.; Lambrecht, R.; Najdovski, L.; Collier, T.L.; Cardaci, G.; Davis, S.; Laing, B.; Mastaglia, F.L.; O'Brien, J.; ANSTO, Lucas Heights, NSW,

    1997-01-01

    Full text; The clinical distinction between idiopathic Parkinson's disease (IPD) and other neurodegenerative disorders which mimic this condition is important in patient management. Iodine-123 lodobenzamide (IBZM) SPECT imaging of cerebral dopamine-2 (D 2 ) receptors has been proposed as a means of distinguishing between IPD and atypical variants, including such Parkinsonian syndromes (PS) as multi-system atrophy and progressive supranuclear palsy, and to predict long-term responsiveness to dopaminergic drugs. Apomorphine testing is currently in use for the latter purpose. To assess the role of IBZM SPECT, MRI and apomorphine testing in categorising patients with Parkinsonian symptoms and for predicting therapeutic response, we studied 40 subjects, 18 of whom had IPD. SPECT brain studies were carried out two hours after the intravenous injection of approximately 185 MBq of 123 I IBZM. Semiquantitative IBZM striatal/occipital cortex uptake ratios in the IPD group were 1.53 + 0.17 (mean + S.D.), and in the non-lPD group 1.53 ± 0.29. Of the 11 IPD patients and 19 non-lPD patients who had MRI, none and two, respectively, showed iron deposition in the basal ganglia. Eleven of 13 IPD and 3 of 18 non-lPD subjects had a positive apomorphine test, while 15 of 15 IPD and 5 of 19 non-lPD subjects responded to dopaminergic therapy. When patients were classified into responders (R) (n 20) and non-responders (NR) (n = 14), the IBZM ratios were 1.56 ± 0.22 and 1.47 ± 0.29 respectively (no significant difference between the groups). The apomorphine test accurately predicted response, being positive in 13 of 15 R and negative in 11 of 12 NR. We conclude that 123 I SPECT is not helpful in differentiating IPD from PS, nor in predicting response to dopaminergic drugs

  11. Cardiac iodine-123 metaiodobenzylguanidine uptake in animals with diabetes mellitus and/or hypertension

    International Nuclear Information System (INIS)

    Dubois, E.A.; Kam, K.L.; Somsen, G.A.; Boer, G.J.; Bruin, K. de; Batink, H.D.; Pfaffendorf, M.; Royen, E.A. van; Zwieten, P.A. van

    1996-01-01

    The aim of the present study was to evaluate the use of the noradrenaline analogue iodine-123 metaiodobenzylguanidine ([ 123 I]MIBG) for the assessment of cardiac sympathetic activity in the presence of diabetes mellitus and/or hypertension in animal models. One model used Wistar-Kyoto rats (WKY) and spontaneously hypertensive rats (SHR) rendered diabetic at 12 weeks of age by an intravenous injection of streptozotocin (STZ). The other model used lean and obese Zucker rats. In all groups basic haemodynamic values were established and animals received an intravenous injection of 50 μCi [ 123 I]MIBG. Initial myocardial uptake and washout rates of [ 123 I]MIBG were measured scintigraphically during 4 h. After sacrifice, plasma noradrenaline and left cardiac ventricular β-adrenoceptor density was determined. The diabetic state, both in STZ-treated rats (direct induction) and in obese Zucker rats (genetic induction), appeared to induce a lower cardiac density of β-adrenoceptors, indicative of increased sympathetic activity. Cardiac [ 123 I]MIBG then showed increased washouts, thereby confirming enhanced noradrenergic activity. This parallism of results led to the conclusion that [ 123 I]MIBG wash-out measurements could provide an excellent tool to assess cardiac sympathetic activity noninvasively. However, in hypertension (WKY vs SHR), both parameters failed to show parallelism: no changes in β-adrenoceptor density were found, whereas [ 123 I]MIBG wash-out rate was increased. Thus, either [ 123 I]MIBG washout or β-adrenoceptor density may not be a reliable parameter under all circumstances to detect changes in the release of noradrenaline. (orig./MG)

  12. Iodine-123 lodobenzamide imaging, MRI and apomorphine testing in the evaluation of patients with Parkinsonism.

    Energy Technology Data Exchange (ETDEWEB)

    Van der Schaaf, A.A.; Stell, R.; Groom, G.N.; Lambrecht, R.; Najdovski, L.; Collier, T.L.; Cardaci, G.; Davis, S.; Laing, B.; Mastaglia, F.L.; O`Brien, J. [Sir Charles Gairdner Hospital, Perth, WA, (Australia)]|[ANSTO, Lucas Heights, NSW, (Australia). The Biomedicine and Health Program

    1997-09-01

    Full text; The clinical distinction between idiopathic Parkinson`s disease (IPD) and other neurodegenerative disorders which mimic this condition is important in patient management. Iodine-123 lodobenzamide (IBZM) SPECT imaging of cerebral dopamine-2 (D{sub 2}) receptors has been proposed as a means of distinguishing between IPD and atypical variants, including such Parkinsonian syndromes (PS) as multi-system atrophy and progressive supranuclear palsy, and to predict long-term responsiveness to dopaminergic drugs. Apomorphine testing is currently in use for the latter purpose. To assess the role of IBZM SPECT, MRI and apomorphine testing in categorising patients with Parkinsonian symptoms and for predicting therapeutic response, we studied 40 subjects, 18 of whom had IPD. SPECT brain studies were carried out two hours after the intravenous injection of approximately 185 MBq of {sup 123}I IBZM. Semiquantitative IBZM striatal/occipital cortex uptake ratios in the IPD group were 1.53 + 0.17 (mean + S.D.), and in the non-lPD group 1.53 {+-} 0.29. Of the 11 IPD patients and 19 non-lPD patients who had MRI, none and two, respectively, showed iron deposition in the basal ganglia. Eleven of 13 IPD and 3 of 18 non-lPD subjects had a positive apomorphine test, while 15 of 15 IPD and 5 of 19 non-lPD subjects responded to dopaminergic therapy. When patients were classified into responders (R) (n 20) and non-responders (NR) (n = 14), the IBZM ratios were 1.56 {+-} 0.22 and 1.47 {+-} 0.29 respectively (no significant difference between the groups). The apomorphine test accurately predicted response, being positive in 13 of 15 R and negative in 11 of 12 NR. We conclude that {sup 123}I SPECT is not helpful in differentiating IPD from PS, nor in predicting response to dopaminergic drugs.

  13. Single-photon manipulation in Nanophotonic Circuits

    DEFF Research Database (Denmark)

    Hansen, Sofie Lindskov

    on a gallium arsenide platform. This platform offers near-unity coupling between embedded single-photon emitters and a photonic mode, as well as the ability to suppress decoherence mechanisms, making it highly suited for quantum information applications. In this thesis we show how a single-photon router can...

  14. Preparation of iodine-123 labeled AM251: a potential SPECT radioligand for the brain cannabinoid CB1 receptor

    Energy Technology Data Exchange (ETDEWEB)

    Lan, Ruoxi; Makriyannis, Alexandros [Connecticut Univ., Molecular and Cell Biology Dept., Storrs, CT (United States); Gatley, S.J. [Brookhaven National Lab., Medical Dept., Upton, NY (United States)

    1996-10-01

    We report the synthesis and labeling with iodine-123 of N-(piperidin-1-yl)-5-(4-iodophenyl)-1-(2, 4-dichlorophenyl)-4-methyl-1H-pyrazole-3-carboxamide (AM251). This compound is an analog of the recently described cannabinoid receptor antagonist, SR141716A, in which a 4-chlorophenyl group is replaced by 4-iodophenyl. Labeling in good yield (62%) and radiochemical purity (> 95%), and high specific activity (> 2500 Ci/mmol) was achieved by an iododestannylation reaction using the tributyltin precursor, no carrier added I-123 iodide, and chloramine-T. (author).

  15. Demonstration of disturbed free fatty acid metabolism of myocardium in patients with non-insulin-dependent diabetes mellitus as measured with iodine-123-heptadecanoic acid

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J.T. (Kuopio Central Hospital (Finland). Dept. of Clinical Physiology); Mustonen, J.N.; Uusitupa, M.I.J.; Rautio, P.; Vanninen, E.; Laakso, M.; Laensimies, E. (Kuopio Central Hospital (Finland). Dept. of Medicine Kuopio Central Hospital (Finland). Dept. of Clinical Nutrition)

    1991-07-01

    Myocardial free fatty acid metabolism and left ventricular function were evaluated in 15 middle-aged patients with non-insulin dependent diabetes mellitus (NIDDM) and in 8 healthy control subjects. The study subjects had no evidence of coronary heart disease on the basis of clinical history, exercise ECG or myocardial perfusion scintigraphy. During peak exercise, iodine-123 hepatadecanoic acid (HDA) was intravenously injected. Myocardial activity distribution of {sup 123}I-HDA was measured 10, 30, and 50 min after exercise using single-photon emission tomography (SPET); and then further corrected by free {sup 123}I-iodine. Venous blood samples were drawn for detecting the plasma activity of {sup 123}I. The net extraction of {sup 123}I-HDA into the myocardium was obtained by dividing the corrected tissue {sup 123}I concentration by the integral of the plasma time activity curve. The net extraction was 0.40+-0.06 min{sup {minus}1} (mean+-SD) patients with NIDDM and 0.38+-0.006 min{sup {minus}1} in control subjects (P>0.1), respectively. The faster elimination rate of {sup 123}I-HDA was found in patients with NIDDM (0.029+-0.008 min{sup {minus}1}) than in control subjects (0.022+-0.004 min{sup {minus}1}); (P<0.01). There no statistically significant difference in left ventricular ejection fraction (LVEF) at rest between patients with NIDDM (53+-9%) and control subjects (56+-2%), whereas the increase of LVEF during exercise remained lower in patients with NIDDM (3.4+-8.2) than in control subjects (11.8+-5.8%; P<0.025). A significant correlation (r=0.64; P<0.01) was found between the net extraction of {sup 123}I-HDA and the change of LVEF, as well as with exercise load (r=0.68; P<0.01). In conclusion, evidence of an increased fatty acid utilization and triglyceride synthesis rate was observed in the diabetic myocardium. (orig.).

  16. Non-matched images with 123I-IMP and 99mTc-bicisate single-photon emission tomography in the demonstration of focal hyperaemia during the subacute phase of an ischaemic stroke

    International Nuclear Information System (INIS)

    Tamgac, F.; Moretti, J.L.; Defer, G.; Weinmann, P.; Roussi, A.; Cesaro, P.

    1994-01-01

    Focal hyperaemia is a fairly common phenomenon in the subacute phase of an ischaemic stroke. This has rarely been reported with iodine-123 iodoamphetamine (IMP) and has never been identified using technetium-99m bicisate ( 99m Tc-ECD. In this report, we present the case of a patient suffering from a ledt cerebral posterior stroke. 123 I-IMP single-photon emission tomography (SPET) images showed a large area of significantly increased IMP activity located in the left occipital region whereas 99m Tc-bicisate SPET displayed hypoactivity in the same area. (orig.)

  17. Estrogen receptor status in primary breast cancer: iodine 123-labeled cis-11beta-methoxy-17alpha-iodovinyl estradiol scintigraphy

    NARCIS (Netherlands)

    Bennink, R. J.; Rijks, L. J.; van Tienhoven, G.; Noorduyn, L. A.; Janssen, A. G.; Sloof, G. W.

    2001-01-01

    PURPOSE: To determine the sensitivity of iodine 123 ((123)I)-labeled cis-11beta-methoxy-17alpha-iodovinyl estradiol (Z-MIVE) scintigraphy for the detection of estrogen receptors in patients with primary breast carcinoma. MATERIALS AND METHODS: In 22 patients, estrogen receptor status was assessed

  18. Single photon from a single trapped atom

    International Nuclear Information System (INIS)

    Dingjan, J.; Jones, M.P.A.; Beugnon, J.; Darquiee, B.; Bergamini, S.; Browaeys, A.; Messin, G.; Grangier, P.

    2005-01-01

    Full text: A quantum treatment of the interaction between atoms and light usually begins with the simplest model system: a two-level atom interacting with a monochromatic light wave. Here we demonstrate an elegant experimental realization of this system using an optically trapped single rubidium atom illuminated by resonant light pulses. We observe Rabi oscillations, and show that this system can be used as a highly efficient triggered source of single photons with a well-defined polarisation. In contrast to other sources based on neutral atoms and trapped ions, no optical cavity is required. We achieved a flux of single photons of about 10 4 s -1 at the detector, and observe complete antibunching. This source has potential applications for distributed atom-atom entanglement using single photons. (author)

  19. Quantum identity authentication with single photon

    Science.gov (United States)

    Hong, Chang ho; Heo, Jino; Jang, Jin Gak; Kwon, Daesung

    2017-10-01

    Quantum identity authentication with single photons is proposed in the paper. It can verify a user's identity without exposing to an authentication key information. The protocol guarantees high efficiency in that it can verify two bits of authentication information using just a single photon. The security of our authentication scheme is analyzed and confirmed in the case of a general attack. Moreover, the proposed protocol is practicable with current technology. Our quantum identity authentication protocol does not require quantum memory registration and any entangled photon sources.

  20. Single-photon manipulation in Nanophotonic Circuits

    DEFF Research Database (Denmark)

    Hansen, Sofie Lindskov

    be realized on a chip with embedded quantum dots. This allows for on-chip generation and manipulation of single photons. The router consists of an on-chip interferometer where the phase difference between the arms of the interferometer is controlled electrically. The response time of the device......Quantum dots in photonic nanostructures has long been known to be a very powerful and versatile solid-state platform for conducting quantum optics experiments. The present PhD thesis describes experimental demonstrations of single-photon generation and subsequent manipulation all realized...

  1. Dosimetry estimation of SPECT/CT for iodine 123-labeled metaiodobenzylguanidine in children

    Directory of Open Access Journals (Sweden)

    Aida Mhiri

    2015-09-01

    Full Text Available Purpose: To evaluate the additional radiation exposure in terms of effective dose incurred by patients in the CT (computed tomography portion of 123I-MIBG (123II-metaiodobenzylguanidine study with SPECT/CT (Single photon emission computed tomography associated to computed tomography in some pediatric patients of our department. Methods: Data from 123II-MIBG scans comprising 50 children were presented in this study. The contribution of total effective dose imparted by the nuclear tracer and patient's age was calculated. Effective dose from the CT portion of the examination is also estimated.SPECT acquisitions were performed with a dual-headed SPECT unit with an integrated 2-slice CT scanner (Symbia T E-Cam, Siemens Medical Systems, Erlangen, Germany. The CT acquisition were performed using a tube current modulation system (Care Dose 4D. Parameters used were: tube current of 30 - 60 mAs, slice thickness of 3-5 mm, and tube voltage of 110 kV. Results: Our results show that SPECT dosimetry depends on administered activity and patient’s age and weight. For CT scan, effective dose is affected by tube current (mA, tube potential (kVp, rotation speed, pitch, slice thickness, patient mass, and the exact volume of the patient that is being imaged. Conclusion: For children, 123II-MIBG study with SPECT/CT should be performed using the lowest available voltage and current. A sensible choice of these two parameters used can significantly reduce radiation dose, without any compromise in the quality of the diagnostic information.

  2. Single Photon Experiments and Quantum Complementarity

    Directory of Open Access Journals (Sweden)

    Georgiev D. D.

    2007-04-01

    Full Text Available Single photon experiments have been used as one of the most striking illustrations of the apparently nonclassical nature of the quantum world. In this review we examine the mathematical basis of the principle of complementarity and explain why the Englert-Greenberger duality relation is not violated in the configurations of Unruh and of Afshar.

  3. Single-photon imaging in CMOS

    NARCIS (Netherlands)

    Charbon, E.

    2010-01-01

    We report on the architectural design and fabrication of medium and large arrays of single-photon avalanche diodes (SPADs) for a variety of applications in physics, medicine, and the life sciences. Due to dynamic nature of SPADs, designs featuring a large number of SPADs require careful analysis of

  4. Simultaneous 99mTC and 123I Dual-Isotope Brain Striatal Phantom Single Photon Emission Computed Tomography: Validation of 99mTC-Trodat-1 and 123I-IBZM Simultaneous Dopamine System Brain Imaging

    OpenAIRE

    Pan-Fu Kao; Shiaw-Pyng Wey; An-Shoei Yang

    2009-01-01

    [2[[2-[[[3-(4-chlorophenyl)-8-methyl-8-azabicyclo[3,2,1]-oct-2-yl]-methyl](2-mercaptoethyl)amino]ethyl]amino]ethanethiolato(3-)-N2,N2′,S2,S2]oxo-[1R-exo-exo)])-[99mTc]-technetium (99mTc-TRODAT-1) and 123I-iodobenzamide (123I-IBZM) are radiotracers for brain dopamine preand postsynaptic neuron imaging. The purpose of this study was to evaluate imaging parameters and crossed energy interference using simultaneous single photon emission computed tomography (SPECT) 99mTc and 123I data acquisition...

  5. Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector

    Energy Technology Data Exchange (ETDEWEB)

    Shcheslavskiy, V., E-mail: vis@becker-hickl.de; Becker, W. [Becker & Hickl GmbH, Nahmitzer Damm 30, 12277 Berlin (Germany); Morozov, P.; Divochiy, A. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Vakhtomin, Yu. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Moscow State Pedagogical University, 1/1 M. Pirogovskaya St., Moscow 119991 (Russian Federation); Smirnov, K. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Moscow State Pedagogical University, 1/1 M. Pirogovskaya St., Moscow 119991 (Russian Federation); National Research University Higher School of Economics, 20 Myasnitskaya St., Moscow 101000 (Russian Federation)

    2016-05-15

    Time resolution is one of the main characteristics of the single photon detectors besides quantum efficiency and dark count rate. We demonstrate here an ultrafast time-correlated single photon counting (TCSPC) setup consisting of a newly developed single photon counting board SPC-150NX and a superconducting NbN single photon detector with a sensitive area of 7 × 7 μm. The combination delivers a record instrument response function with a full width at half maximum of 17.8 ps and system quantum efficiency ∼15% at wavelength of 1560 nm. A calculation of the root mean square value of the timing jitter for channels with counts more than 1% of the peak value yielded about 7.6 ps. The setup has also good timing stability of the detector–TCSPC board.

  6. Iodine-123-metaiodobenzylguanidine cardiac scintigraphy in patients with diabetes mellitus. Therapeutic effects of aldose reductase inhibitor and vitamin B12

    International Nuclear Information System (INIS)

    Utsunomiya, Keita

    1997-01-01

    Twenty normal volunteers (C group) and 56 patients with non-insulin-dependent diabetes mellitus (NIDDM) who did not have ischemic heart diseases (DM group), were evaluated by means of iodine-123-metaiodobenzylguanidine (MIBG) scintigraphy. The uptake ratio between the cardiac muscle and the upper mediastinum was calculated. The ratio determined from the initial I-123-MIBG scintigraphy image was expressed as HMi, and that determined from the delayed image was expressed as HMd. The washout rate percentage (%WR) was calculated. At least one instance of either the HMi, the HMd, or %WR was outside the mean±1 standard deviation of C group in 34 DM group patients. Aldose reductase inhibitor (ARI) was administered to 17 of the 34 patients and Vitamin B 12 (VB 12 ) to the remaining 17 patients, for 3 to 5 months. Before and after treatment, scintigraphic studies with I-123-MIBG were carried out, and the HMi, HMd, and %WR were calculated. There were no significant differences found in FBG, HbA1c, or 1.5-AG levels after treatment with either drug, when compared to the pretreatment values. Both HMi and HMd in the DM group were significantly lower, and %WR was significantly higher than in the C group. The changes in HMi, HMd, and %WR after treatment with ARI were not significant. After treatment with VB 12 , the HMi and HMd levels were significantly increased (p 12 was shown to be effective for improvement of HMi and HMd in NIDDM. (author)

  7. Single Photon Double Ionization of Atomic Oxygen

    Science.gov (United States)

    Wickramarathna, Madhushani; Gorczyca, Thomas; Ballance, Connor; Stolte, Wayne

    2017-04-01

    Single photon double ionization cross sections are calculated using an R-matrix with pseudostates (RMPS) method which was recently applied by Gorczyca et al. for the double photoionization of helium. With the convergence of these theoretical calculations for the simple case of helium, we extend this methodology to consider the more complex case of oxygen double photoionization. We compare our calculated results with recent measurements at the Advanced Light Source, as well as earlier experimental measurements. Our RMPS results agree well, qualitatively, with the experimental measurements, but there exist outstanding discrepancies to be addressed. This project is supported by NASA APRA award NNX17AD41G.

  8. A search for single photons at PETRA

    International Nuclear Information System (INIS)

    Behrend, H.J.; Buerger, J.; Criegee, L.; Fenner, H.; Field, J.H.; Franke, G.; Fuster, J.; Holler, Y.; Meyer, J.; Schroeder, V.; Sindt, H.; Timm, U.; Winter, G.G.; Zimmermann, W.; Bussey, P.J.; Buttar, C.; Campbell, A.J.; Dainton, J.B.; Hendry, D.; McCurrach, G.; Scarr, J.M.; Skillicorn, I.O.; Smith, K.M.; Blobel, V.; Feindt, M.; Poppe, M.; Spitzer, H.; Boer, W. de; Buschhorn, G.; Christiansen, W.; Grindhammer, G.; Gunderson, B.; Kiesling, C.; Kotthaus, R.; Kroha, H.; Lueers, D.; Oberlack, H.; Sack, B.; Schacht, P.; Shooshtari, G.; Wiedenmann, W.; Cordier, A.; Davier, M.; Fournier, D.; Gaillard, M.; Grivaz, J.F.; Haissinski, J.; Journe, V.; Le Diberder, F.; Ros, E.; Spadafora, A.; Veillet, J.J.; Aleksan, R.; Cozzika, G.; Ducros, Y.; Lavagne, Y.; Ould Saada, F.; Pamela, J.; Pierre, F.; Zacek, J.; Alexander, G.; Bella, G.; Gnat, Y.; Grunhaus, J.; Levy, A.

    1986-01-01

    A search for single photons, produced in e + e - collisions together with particles interacting only weakly with matter, has been performed using the CELLO detector operating at the PETRA storage ring. From the absence of any signal, an upper limit is set at 15 (90% CL) on the number of light neutrino species, and lower limits on various supersymmetric particle masses are derived. For massless photinos, mass degenerate scalar partners of the left- and right-handed electrons are excluded below 37.7 GeV/c 2 (90% CL). (orig.)

  9. Biodistribution and dosimetry of (iodine-123)-iodomethyl-N,N-diethyltamoxifen, an (anti)oestrogen receptor radioligand

    International Nuclear Information System (INIS)

    Wiele, C. van de; Sutter, J. de; Dierckx, R.A.; Vos, F. de; Dumont, F.; Slegers, G.; Thierens, H.

    1999-01-01

    This study reports on the distribution and radiation dosimetry of iodine-123 labelled trans-Z-iodomethyl-N,N-diethyltamoxifen (123-ITX), a promising radioligand for prediction of the therapeutic efficacy of unlabelled tamoxifen in human breast carcinoma. Whole-body scans were performed up to 24 h after intravenous injection of 123-ITX (mean: 146 MBq, range: 142-148 MBq) in five female volunteers, four with and one without thyroid blockade. Blood samples were taken at various times up to 24 h after injection. Urine was also collected up to 24 h after injection, allowing calculation of renal clearance and interpretation of whole-body clearance. Time-activity curves were generated for the thyroid, heart, brain, breasts, liver and gallbladder by fitting the organ-specific geometric mean counts, obtained from regions of interest. The MIRD formulation was applied to calculate the absorbed radiation doses for various organs. The images showed rapid hepatobiliary excretion, resulting in good imaging conditions for the thoracic region, whereas imaging of the abdominal region was impeded by extensive bowel activity. The breast to non-specific uptake ratio increased over time. 123-ITX was cleared by both the kidneys and the gastrointestinal tract. At 50 h p.i. the mean excretion in the urine was 89.4% (SD 5.7%). If the thyroid was not blocked, it was one of the critical organs. The highest absorbed doses were received by the excretory organs, i.e. the urinary bladder wall, the lower and upper large intestine, and the gallbladder wall. The average effective dose of 123-ITX was estimated to be 0.0084 mSv/MBq. The amount of 123-ITX required for adequate imaging of tumoral uptake results in an acceptable effective dose to the patient. (orig.)

  10. Disease stage classification in hypertrophic cardiomyopathy by dual analysis of iodine-123-labeled metaiodobenzylguanidine and thallium-201 myocardial scintigraphies

    Energy Technology Data Exchange (ETDEWEB)

    Hiasa, Go [Ehime Univ., Matsuyama (Japan). School of Medicine

    2001-08-01

    Many patients with hypertrophic cardiomyopathy (HCM) gradually changes from typical myocardial hypertrophy to dilated cardiomyopathy-like features. However, it is difficult to estimate the disease stage in HCM. To determine the disease stage, dual analysis of iodine-123-labeled metaiodobenzylguanidine ({sup 123}I-MIBG) and thallium-201 ({sup 201}Tl) myocardial scintigraphies were performed in 108 HCM patients. According to the scintigraphic distribution patterns, patients were divided into three groups. Group A (n=15): normal distributions of both {sup 123}I-MIBG and {sup 201}Tl, group B (n=71): normal {sup 201}Tl and low {sup 123}I-MIBG patterns, group C (n=22): low distributions of both scintigraphies. The decrease in {sup 201}Tl uptake was observed in only group C. Concerning {sup 123}I-MIBG, heart-to-mediastinum ratio (H/M) and washout rate (WOR) had good correlations with left ventricular systolic functions. H/M was decreased and WOR was increased in order of C, B and A groups. Left ventricular diastolic function reflected by isovolumic relaxation time was longer in group B than in group A. Attenuated left ventricular hypertrophy, enlarged left ventricular volumes, impaired left ventricular functions and serious clinical symptoms were observed in only group C. Myocardial sympathetic abnormalities in group B may be mainly due to myocardial hypertrophy, and those in group C may be due to myocardial injury. Dual analysis of {sup 123}I-MIBG and {sup 201}Tl scintigraphies may be useful to classify disease stages of HCM. (author)

  11. Imaging active lymphocytic infiltration in coeliac disease with iodine-123-interleukin-2 and the response to diet

    International Nuclear Information System (INIS)

    Signore, A.; Chianelli, M.; Annovazzi, A.; Rossi, M.; Greco, M.; Ronga, G.; Picarelli, A.; Maiuri, L.; Britton, K.E.

    2000-01-01

    Coeliac disease is diagnosed by the presence of specific antibodies and a jejunal biopsy showing mucosal atrophy and mononuclear cell infiltration. Mucosal cell-mediated immune response is considered the central event in the pathogenesis of coeliac disease, and untreated coeliac patients show specific features of T-cell activation in the small intestine. Here we describe the use of iodine-123-interleukin-2 scintigraphy in coeliac patients as a non-invasive tool for detection of lymphocytic infiltration in the small bowel and its use for therapy follow-up, and we demonstrate the specificity of binding of labelled-IL2 to activated lymphocytes by ex-vivo autoradiography of jejunal biopsies. 123 I-IL2 was administered i.v. [74 MBq (2 mCi)], and gamma camera images were acquired after 1 h. Ten patients were studied with 123 I-IL2 scintigraphy at diagnosis and seven were also investigated after 12-19 months of gluten-free diet. Results were expressed as target-to-background radioactivity ratios in six different bowel regions before and after the diet. At the time of diagnosis all patients showed a significantly higher bowel uptake of 123 I-IL2 than normal subjects (P 2 =0.66; P=0.008). Autoradiography of jejunal biopsies confirmed that labelled-IL2 only binds to activated T-lymphocytes infiltrating the gut mucosa. After 1 year of the diet, bowel uptake of 123 I-IL2 significantly decreased in five out of six regions (P 123 I-IL2 scintigraphy is a sensitive non-invasive technique for assessing in vivo the presence of activated mononuclear cells in the bowel of patients affected by coeliac disease. Unlike jejunal biopsy, this method provides information from the whole intestine and gives a non-invasive measure of the effectiveness of the gluten-free diet. (orig.)

  12. Sub-megahertz linewidth single photon source

    Directory of Open Access Journals (Sweden)

    Markus Rambach

    2016-12-01

    Full Text Available We report 100% duty cycle generation of sub-MHz single photon pairs at the rubidium D1 line using cavity-enhanced spontaneous parametric downconversion. The temporal intensity cross correlation function exhibits a bandwidth of 666±16 kHz for the single photons, an order of magnitude below the natural linewidth of the target transition. A half-wave plate inside our cavity helps to achieve triple resonance between pump, signal, and idler photon, reducing the bandwidth and simplifying the locking scheme. Additionally, stabilisation of the cavity to the pump frequency enables the 100% duty cycle. The quantum nature of the source is confirmed by the idler-triggered second-order autocorrelation function at τ=0 to be gs,s(2(0= 0.016±0.002 for a heralding rate of 5 kHz. The generated photons are well-suited for storage in quantum memory schemes with sub-natural linewidths, such as gradient echo memories.

  13. Changing optical band structure with single photons

    Science.gov (United States)

    Albrecht, Andreas; Caneva, Tommaso; Chang, Darrick E.

    2017-11-01

    Achieving strong interactions between individual photons enables a wide variety of exciting possibilities in quantum information science and many-body physics. Cold atoms interfaced with nanophotonic structures have emerged as a platform to realize novel forms of nonlinear interactions. In particular, when atoms are coupled to a photonic crystal waveguide, long-range atomic interactions can arise that are mediated by localized atom-photon bound states. We theoretically show that in such a system, the absorption of a single photon can change the band structure for a subsequent photon. This occurs because the first photon affects the atoms in the chain in an alternating fashion, thus leading to an effective period doubling of the system and a new optical band structure for the composite atom-nanophotonic system. We demonstrate how this mechanism can be engineered to realize a single-photon switch, where the first incoming photon switches the system from being highly transmissive to highly reflective, and analyze how signatures can be observed via non-classical correlations of the outgoing photon field.

  14. Distributed quantum computing with single photon sources

    International Nuclear Information System (INIS)

    Beige, A.; Kwek, L.C.

    2005-01-01

    Full text: Distributed quantum computing requires the ability to perform nonlocal gate operations between the distant nodes (stationary qubits) of a large network. To achieve this, it has been proposed to interconvert stationary qubits with flying qubits. In contrast to this, we show that distributed quantum computing only requires the ability to encode stationary qubits into flying qubits but not the conversion of flying qubits into stationary qubits. We describe a scheme for the realization of an eventually deterministic controlled phase gate by performing measurements on pairs of flying qubits. Our scheme could be implemented with a linear optics quantum computing setup including sources for the generation of single photons on demand, linear optics elements and photon detectors. In the presence of photon loss and finite detector efficiencies, the scheme could be used to build large cluster states for one way quantum computing with a high fidelity. (author)

  15. Single photon imaging. New instrumentation and techniques

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.

    1981-01-01

    The performance of Anger scintillation cameras continues to be enhanced through a series of small improvements which result in significantly better imaging characteristics. The most recent changes in camera design consist of: (1) the introduction of photomultipliers with better photocathode and electron collection efficiencies, (2) the use of thinner (3/8 or 1/4 in) crystals giving slightly better intrinsic resolution for low gamma-ray energies, (3) inclusion of a spatially varying energy window to compensate for variations of light collection efficiency, (4) event-by-event, real-time distortion removal for uniformity correction, and (5) introduction of new methods to improve the count-rate capability. Whereas some of these improvements are due to better understanding of the fundamentals of camera design, others are the result of technological advances in electronic components such as analogue-to-digital converters, microprocessors and high-density digital memories. The development of single photon tomography has developed along two parallel paths. Multipinhole and rotating slant-hole collimator attachments provide some degree of longitudinal tomography, and are currently being applied to cardiac imaging. At the same time rotating camera systems capable of transverse as well as longitudinal imaging are being refined technically and evaluated clinically. Longitudinal tomography is of limited use in quantitative studies and is likely to be an interim solution to three-dimensional imaging. Rotating camera systems, on the other hand, not only provide equal resolution in all three dimensions but are also capable of providing quantitative accuracy. This is the result of progress in attenuation correction and the design of special collimators. Single photon tomography provides a small but noticeable improvement in diagnostic accuracy which is likely to result in widespread use of rotating camera systems in the future

  16. Imaging active lymphocytic infiltration in coeliac disease with iodine-123-interleukin-2 and the response to diet

    Energy Technology Data Exchange (ETDEWEB)

    Signore, A.; Chianelli, M.; Annovazzi, A.; Rossi, M.; Greco, M.; Ronga, G.; Picarelli, A. [Nuclear Medicine Unit (Nu.M.E.D. Group) and Gastroenterology Unit, Department of Clinical Sciences, University of Rome ' ' La Sapienza' ' (Italy); Maiuri, L. [Inst. of Paediatrics, Children' s Hospital Posilipon, University ' ' Federico II' ' , Naples (Italy); Britton, K.E. [Dept. of Nuclear Medicine, St. Bartholomew' s Hospital, London (United Kingdom)

    2000-01-01

    Coeliac disease is diagnosed by the presence of specific antibodies and a jejunal biopsy showing mucosal atrophy and mononuclear cell infiltration. Mucosal cell-mediated immune response is considered the central event in the pathogenesis of coeliac disease, and untreated coeliac patients show specific features of T-cell activation in the small intestine. Here we describe the use of iodine-123-interleukin-2 scintigraphy in coeliac patients as a non-invasive tool for detection of lymphocytic infiltration in the small bowel and its use for therapy follow-up, and we demonstrate the specificity of binding of labelled-IL2 to activated lymphocytes by ex-vivo autoradiography of jejunal biopsies. {sup 123}I-IL2 was administered i.v. [74 MBq (2 mCi)], and gamma camera images were acquired after 1 h. Ten patients were studied with {sup 123}I-IL2 scintigraphy at diagnosis and seven were also investigated after 12-19 months of gluten-free diet. Results were expressed as target-to-background radioactivity ratios in six different bowel regions before and after the diet. At the time of diagnosis all patients showed a significantly higher bowel uptake of {sup 123}I-IL2 than normal subjects (P<0.003 in all regions). A significant correlation was found between jejunal radioactivity and the number of IL2R+ve lymphocytes per millimetre of jejunal mucosa as detected by immunostaining of jejunal biopsy (r{sup 2}=0.66; P=0.008). Autoradiography of jejunal biopsies confirmed that labelled-IL2 only binds to activated T-lymphocytes infiltrating the gut mucosa. After 1 year of the diet, bowel uptake of {sup 123}I-IL2 significantly decreased in five out of six regions (P<0.03), although two patients still had a positive IL2 scintigraphy in one region. We conclude that {sup 123}I-IL2 scintigraphy is a sensitive non-invasive technique for assessing in vivo the presence of activated mononuclear cells in the bowel of patients affected by coeliac disease. Unlike jejunal biopsy, this method provides

  17. Comparison of iodine-123 labelled 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)tropane and 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)-N-(3-fluoropropyl)nortropane for imaging of the dopamine transporter in the living human brain

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J.T. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Bergstroem, K.A. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Ahonen, A. [Dept. of Clinical Chemistry, Oulu Univ. Central Hospital (Finland); Hiltunen, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Haukka, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Laensimies, E. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Wang Shaoyin [Research Biochemicals International (RBI), Natick, MA (United States); Neumeyer, J.L. [Research Biochemicals International (RBI), Natick, MA (United States)

    1995-04-01

    Several cocaine congeners are of potential for imaging the dopamine transporter (DAT). Previous studies have shown that iodine-123 labelled 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)tropane ([{sup 123}I]{beta}-CIT) is a promising radiotracer for imaging the serotonin (5-HT) and dopamine (DA) transporters in the living human brain with single-photon emission tomography (SPET). [{sup 123}I]{beta}-CIT was found to be not very practical for 1-day DAT imaging protocols since peak DAT uptake occurs later than 8 h. Here we report a pilot comparison of [{sup 123}I]{beta}-CIT and 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)-N-(3-fluoropropyl)nortropane ([{sup 123}I]{beta}-CIT-FP), using SPET imaging in four healthy male subjects. Peak uptake of [{sup 123}I]{beta}-CIT-FP into the basal ganglia occurred earlier (3-4 h after injection of tracer) than that of [{sup 123}I]{beta}-CIT (>8 h). However, the specific DAT binding of [{sup 123}I]{beta}-CIT-FP in the basal ganglia was somewhat less (0.813{+-}0.047) than that of [{sup 123}I]{beta}-CIT (0.922{+-}0.004). Imaging quality is excellent with both tracers and they are potentially of value for brain imaging in various neuropsychiatric disorders. (orig.)

  18. Comparison of iodine-123 labelled 2β-carbomethoxy-3β-(4-iodophenyl)tropane and 2β-carbomethoxy-3β-(4-iodophenyl)-N-(3-fluoropropyl)nortropane for imaging of the dopamine transporter in the living human brain

    International Nuclear Information System (INIS)

    Kuikka, J.T.; Bergstroem, K.A.; Ahonen, A.; Hiltunen, J.; Haukka, J.; Laensimies, E.; Wang Shaoyin; Neumeyer, J.L.

    1995-01-01

    Several cocaine congeners are of potential for imaging the dopamine transporter (DAT). Previous studies have shown that iodine-123 labelled 2β-carbomethoxy-3β-(4-iodophenyl)tropane ([ 123 I]β-CIT) is a promising radiotracer for imaging the serotonin (5-HT) and dopamine (DA) transporters in the living human brain with single-photon emission tomography (SPET). [ 123 I]β-CIT was found to be not very practical for 1-day DAT imaging protocols since peak DAT uptake occurs later than 8 h. Here we report a pilot comparison of [ 123 I]β-CIT and 2β-carbomethoxy-3β-(4-iodophenyl)-N-(3-fluoropropyl)nortropane ([ 123 I]β-CIT-FP), using SPET imaging in four healthy male subjects. Peak uptake of [ 123 I]β-CIT-FP into the basal ganglia occurred earlier (3-4 h after injection of tracer) than that of [ 123 I]β-CIT (>8 h). However, the specific DAT binding of [ 123 I]β-CIT-FP in the basal ganglia was somewhat less (0.813±0.047) than that of [ 123 I]β-CIT (0.922±0.004). Imaging quality is excellent with both tracers and they are potentially of value for brain imaging in various neuropsychiatric disorders. (orig.)

  19. Single-photon imaging in complementary metal oxide semiconductor processes

    NARCIS (Netherlands)

    Charbon, E.

    2014-01-01

    This paper describes the basics of single-photon counting in complementary metal oxide semiconductors, through single-photon avalanche diodes (SPADs), and the making of miniaturized pixels with photon-counting capability based on SPADs. Some applications, which may take advantage of SPAD image

  20. Generation of Fourier-transform-limited heralded single photons

    International Nuclear Information System (INIS)

    U'Ren, Alfred B.; Jeronimo-Moreno, Yasser; Garcia-Gracia, Hipolito

    2007-01-01

    In this paper we study the spectral (temporal) properties of heralded single photon wave packets, triggered by the detection of an idler photon in the process of parametric down conversion. The generated single photons are studied within the framework of the chronocyclic Wigner function, from which the single photon spectral width and temporal duration can be computed. We derive specific conditions on the two-photon joint spectral amplitude which result in both pure and Fourier-transform-limited heralded single photons. Likewise, we present specific source geometries which lead to the fulfillment of these conditions and show that one of these geometries leads, for a given pump bandwidth, to the temporally shortest possible heralded single photon wave packets

  1. Single photon emission from ZnO nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sumin; Ton-That, Cuong; Phillips, Matthew R.; Aharonovich, Igor, E-mail: igor.aharonovich@uts.edu.au [School of Physics and Advanced Materials, University of Technology Sydney, Ultimo, New South Wales 2007 (Australia); Johnson, Brett C. [Centre for Quantum Computation and Communication Technology, School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Castelletto, Stefania [School of Aerospace, Mechanical and Manufacturing Engineering, RMIT University, Melbourne, Victoria 3000 (Australia)

    2014-06-30

    Room temperature single photon emitters are very important resources for photonics and emerging quantum technologies. In this work, we study single photon emission from defect centers in 20 nm zinc oxide (ZnO) nanoparticles. The emitters exhibit bright broadband fluorescence in the red spectral range centered at 640 nm with polarized excitation and emission. The studied emitters showed continuous blinking; however, bleaching can be suppressed using a polymethyl methacrylate coating. Furthermore, hydrogen termination increased the density of single photon emitters. Our results will contribute to the identification of quantum systems in ZnO.

  2. Characterization of the nonclassical nature of conditionally prepared single photons

    International Nuclear Information System (INIS)

    U'Ren, Alfred B.; Silberhorn, Christine; Ball, Jonathan L.; Banaszek, Konrad; Walmsley, Ian A.

    2005-01-01

    A reliable single photon source is a prerequisite for linear optical quantum computation and for secure quantum key distribution. A criterion yielding a conclusive test of the single photon character of a given source, attainable with realistic detectors, is therefore highly desirable. In the context of heralded single photon sources, such a criterion should be sensitive to the effects of higher photon number contributions, and to vacuum introduced through optical losses, which tend to degrade source performance. In this Rapid Communication we present, theoretically and experimentally, a criterion meeting the above requirements

  3. Dynamic SPECT with technetium-99m HM-PAO in meningiomas--a comparison with iodine-123 IMP

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, S.; Kinoshita, K.; Jinnouchi, S.; Hoshi, H.; Watanabe, K.

    1989-06-01

    Technetium-99m hexamethylpropyleneamine oxime ((/sup 99m/Tc)HM-PAO) has recently been introduced as an alternative to N-isopropyl-p-/sup 123/I-iodoamphetamine ((/sup 123/I)IMP) for measurement of regional cerebral blood flow. This study compares dynamic SPECT studies using the two tracers in seven patients with meningiomas. Regions of interest were placed over the lesion and contralateral homologous presumed normal area. The counting-rate ratio for the lesion to the contralateral homologous area (L/N ratio) was then calculated in the first image. L/N ratios of ((/sup 99m/Tc)HM-PAO) single photon emission computed tomography (SPECT) were lower than those of ((/sup 123/I)IMP) SPECT, particularly in hypervascular meningiomas. Furthermore, time-activity curves showed that the washout of ((/sup 99m/Tc)HM-PAO) in the tumors was very slow or incomplete, preventing an accurate assessment of vascularity of meningiomas with ((/sup 99m/Tc)HM-PAO), as is generally possible with ((/sup 123/I)IMP).

  4. Heralded single-photon absorption by a single atom

    Science.gov (United States)

    Piro, N.; Rohde, F.; Schuck, C.; Almendros, M.; Huwer, J.; Ghosh, J.; Haase, A.; Hennrich, M.; Dubin, F.; Eschner, J.

    2011-01-01

    Emission and absorption of single photons by single atoms is a fundamental limit of matter-light interaction, manifesting its quantum mechanical nature. As a controlled process, it is also a key tool in quantum optical information technology . Controlled single-photon emission is well advanced ; for controlled single-photon absorption by a single atom, proposals exist but only preliminary experimental steps have been taken . Here we report the absorption of single photons by a single trapped ion: employing a photon pair source, detection of the quantum-correlated partner photon heralds the presence of the resonant photon at the atom. We find clear correlations between the detection of the herald and the absorption process in the atom; we also demonstrate polarization control of this process. Our experiment evidences previously unexplored interaction between a single absorber and a quantum light source; with improved control over the coupling, it will open up new avenues in quantum technology.

  5. Entanglement and quantum superposition induced by a single photon

    Science.gov (United States)

    Lü, Xin-You; Zhu, Gui-Lei; Zheng, Li-Li; Wu, Ying

    2018-03-01

    We predict the occurrence of single-photon-induced entanglement and quantum superposition in a hybrid quantum model, introducing an optomechanical coupling into the Rabi model. Originally, it comes from the photon-dependent quantum property of the ground state featured by the proposed hybrid model. It is associated with a single-photon-induced quantum phase transition, and is immune to the A2 term of the spin-field interaction. Moreover, the obtained quantum superposition state is actually a squeezed cat state, which can significantly enhance precision in quantum metrology. This work offers an approach to manipulate entanglement and quantum superposition with a single photon, which might have potential applications in the engineering of new single-photon quantum devices, and also fundamentally broaden the regime of cavity QED.

  6. Modeling and Development of Superconducting Nanowire Single Photon Detectors

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal outlines a research project as the central component of a Ph.D. program focused on the device physics of superconducting nanowire single photon...

  7. Quantum private comparison employing single-photon interference

    Science.gov (United States)

    Liu, Bin; Xiao, Di; Huang, Wei; Jia, Heng-Yue; Song, Ting-Ting

    2017-07-01

    As a typical quantum cryptographic task between distrustful participants, quantum private comparison (QPC) has attracted a lot of attention in recent years. Here we propose two QPC protocols employing single-photon interference, a typical and interesting technology for quantum communications. Compared with the previous QPC protocols employing normal single states or entangled states, the proposed protocols achieve lower communication complexity utilizing the characteristics of single-photon interference. And we also proved the security of the proposed protocols in theory.

  8. Striatal and extrastriatal imaging of dopamine D2receptors in the living human brain with [ 123I[epidepride single-photon emission tomography

    International Nuclear Information System (INIS)

    Kuikka, J.T.; Aakerman, K.K.; Hiltunen, J.; Bergstroem, K.A.; Raesaenen, P.; Vanninen, E.; Halldin, C.; Tiihonen, J.

    1997-01-01

    The iodine-123 labelled ligand benzamide epidepride was evaluated as a probe for in vivo imaging of striatal and extrastriatal dopamine D 2 receptor sites in the human brain. Four healthy males were imaged with a high-resolution single-photon emission tomography scanner. Striatal radioactivity peaked at 3 h after injection. The specific binding in the striatum was 0.91 ±0.03 at 3 h and this ratio steadily increased with time. Extrastriatal radioactivity was highest in the thalamus, in the midbrain and in the temporal cortex, and peaked at 45-60 min after injection of tracer. A smaller amount of radioactivity was found in the parietal, frontal and occipital cortices. Two radioactive metabolites were observed, of which one was more lipophilic than the parent compound. The radiation burden to the patient was 0.035 mSv/MBq (effective dose equivalent). The preliminary results showed that [ 123 I[epidepride can be used for imaging striatal and extrastriatal dopamine D 2 receptor sites in the living human brain. (orig.). With 5 figs., 1 tab

  9. Enhancement of Single-Photon Sources with Metamaterials

    Science.gov (United States)

    Shalaginov, M. Y.; Bogdanov, S.; Vorobyov, V. V.; Lagutchev, A. S.; Kildishev, A. V.; Akimov, A. V.; Boltasseva, A.; Shalaev, V. M.

    2015-06-01

    Scientists are looking for new, breakthrough solutions that can greatly advance computing and networking systems. These solutions will involve quantum properties of matter and light as promised by the ongoing experimental and theoretical work in the areas of quantum computation and communication. Quantum photonics is destined to play a central role in the development of such technologies due to the high transmission capacity and outstanding low-noise properties of photonic information channels. Among the vital problems to be solved in this direction, are efficient generation and collection of single photons. One approach to tackle these problems is based on engineering emission properties of available single-photon sources using metamaterials. Metamaterials are artificially engineered structures with sub-wavelength features whose optical properties go beyond the limitations of conventional materials. As promising single-photon sources, we have chosen nitrogen-vacancy (NV) color centers in diamond, which are capable to operate stably in a single-photon regime at room temperature in a solid state environment. In this chapter, we report both theoretical and experimental studies of the radiation from a nanodiamond single NV center placed near a hyperbolic metamaterial (HMM). In particular, we derive the reduction of excited-state lifetime and the enhancement of collected single-photon emission rate and compare them with the experimental observations. These results could be of great impact for future integrated quantum sources, especially owing to a CMOS-compatible approach to HMM synthesis.

  10. Single Photon Avalanche Diodes: Towards the Large Bidimensional Arrays

    Directory of Open Access Journals (Sweden)

    Emilio Sciacca

    2008-08-01

    Full Text Available Single photon detection is one of the most challenging goals of photonics. In recent years, the study of ultra-fast and/or low-intensity phenomena has received renewed attention from the academic and industrial communities. Intense research activity has been focused on bio-imaging applications, bio-luminescence, bio-scattering methods, and, more in general, on several applications requiring high speed operation and high timing resolution. In this paper we present design and characterization of bi-dimensional arrays of a next generation of single photon avalanche diodes (SPADs. Single photon sensitivity, dark noise, afterpulsing and timing resolution of the single SPAD have been examined in several experimental conditions. Moreover, the effects arising from their integration and the readout mode have also been deeply investigated.

  11. Single-photon generator for optical telecommunication wavelength

    International Nuclear Information System (INIS)

    Usuki, T; Sakuma, Y; Hirose, S; Takemoto, K; Yokoyama, N; Miyazawa, T; Takatsu, M; Arakawa, Y

    2006-01-01

    We report on the generation of single-photon pulses from a single InAs/InP quantum dot in telecommunication bands (1.3-1.55 μm: higher transmittance through an optical fiber). First we prepared InAs quantum dots on InP (0 0 1) substrates in a low-pressure MOCVD by using a so-called InP 'double-cap' procedure. The quantum dots have well-controlled photo emission wavelength in the telecommunication bands. We also developed a single-photon emitter in which quantum dots were embedded. Numerical simulation designed the emitter to realize efficient injection of the emitted photons into a single-mode optical fiber. Using a Hanbury-Brown and Twiss technique has proved that the photons through the fiber were single photons

  12. Single-photon light detection with transition-edge sensors

    International Nuclear Information System (INIS)

    Rajteri, M.; Taralli, E.; Portesi, C.; Monticone, E.

    2008-01-01

    Transition-Edge Sensors (TESs) are micro calorimeters that measure the energy of incident single-photons by the resistance increase of a superconducting film biased within the superconducting-to-normal transition. TES are able to detect single photons from x-ray to IR with an intrinsic energy resolution and photon-number discrimination capability. Metrological, astronomical and quantum communication applications are the fields where these properties can be particularly important. In this work, we report about characterization of different TESs based on Ti films. Single-photons have been detected from 200 nm to 800 nm working at T c ∼ 100 m K. Using a pulsed laser at 690 nm we have demonstrated the capability to resolve up to five photons.

  13. Optimization of time-correlated single photon counting spectrometer

    International Nuclear Information System (INIS)

    Zhang Xiufeng; Du Haiying; Sun Jinsheng

    2011-01-01

    The paper proposes a performance improving scheme for the conventional time-correlated single photon counting spectrometer and develops a high speed data acquisition card based on PCI bus and FPGA technologies. The card is used to replace the multi-channel analyzer to improve the capability and decrease the volume of the spectrometer. The process of operation is introduced along with the integration of the spectrometer system. Many standard samples are measured. The experimental results show that the sensitivity of the spectrometer is single photon counting, and the time resolution of fluorescence lifetime measurement can be picosecond level. The instrument could measure the time-resolved spectroscopy. (authors)

  14. CMOS-compatible photonic devices for single-photon generation

    Directory of Open Access Journals (Sweden)

    Xiong Chunle

    2016-09-01

    Full Text Available Sources of single photons are one of the key building blocks for quantum photonic technologies such as quantum secure communication and powerful quantum computing. To bring the proof-of-principle demonstration of these technologies from the laboratory to the real world, complementary metal–oxide–semiconductor (CMOS-compatible photonic chips are highly desirable for photon generation, manipulation, processing and even detection because of their compactness, scalability, robustness, and the potential for integration with electronics. In this paper, we review the development of photonic devices made from materials (e.g., silicon and processes that are compatible with CMOS fabrication facilities for the generation of single photons.

  15. Design and simulations of highly efficient single-photon sources

    DEFF Research Database (Denmark)

    Gregersen, Niels; de Lasson, Jakob Rosenkrantz; Mørk, Jesper

    The realization of the highly-efficient single-photon source represents not only an experimental, but also a numerical challenge. We will present the theory of the waveguide QED approach, the design challenges and the current limitations. Additionally, the important numerical challenges in the si......The realization of the highly-efficient single-photon source represents not only an experimental, but also a numerical challenge. We will present the theory of the waveguide QED approach, the design challenges and the current limitations. Additionally, the important numerical challenges...

  16. Single-photon interference experiment for high schools

    Science.gov (United States)

    Bondani, Maria

    2014-07-01

    We follow the reductio ad absurdum reasoning described in the book "Sneaking a Look at God's Cards" by Giancarlo Ghirardi to demonstrate the wave-particle duality of light in a Mach-Zehnder interferometric setup analog to the conventional Young double-slit experiment. We aim at showing the double nature of light by measuring the existence of interference fringes down to the single-photon level. The setup includes a strongly attenuated laser, polarizing beam splitters, half-waveplates, polarizers and single-photon detectors.

  17. Alternating myocardial sympathetic neural function of athlete's heart in professional cycle racers examined with iodine-123-MIBG myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, Keiko; Inoue, Tomio; Hasegawa, Akira; Oriuchi, Noboru; Okamoto, Eiichi; Tomaru, Yumi; Endo, Keigo [Gunma Univ., Maebashi (Japan). School of Medicine

    2001-08-01

    Myocardial sympathetic neural function in professional athletes who had the long-term tremendous cardiac load has not been fully investigated by myocardial iodine-123-metaiodobenzylguanidine (MIBG) uptake in comparison with power spectral analysis (PSA) in electrocardiography. Eleven male professional cycle racers and age-matched 11 male healthy volunteers were enrolled in this study. The low frequency components in the power spectral density (LF), the high frequency components in the power spectral density (HF), the LF/HF ratio and mean R-R interval were derived from PSA and time-domain analysis of heart rate variability in electrocardiography. The mean heart-to-mediastinum uptake ratio (H/M ratio) of the MIBG uptake, in professional cycle racers was significantly lower than that in healthy volunteers (p<0.01) and HF power in professional cycle racers was significantly higher than that in healthy volunteers (p<0.05). In the group of professional cycle racers, the H/M ratio showed a significant correlation with the R-R interval, as indices of parasympathetic nerve activity (r=0.80, p<0.01), but not with the LF/HF ratio as an index of sympathetic nerve activity. These results may indicate that parasympathetic nerve activity has an effect on MIBG uptake in a cyclist's heart. (author)

  18. Myocardial rest iodine-123-{beta}-methyl-iodophenyl-pentadecanoic acid scintigraphy compared with dipyridamole stress thallium-201 scintigraphy in unstable angina

    Energy Technology Data Exchange (ETDEWEB)

    Misumi, Ikuo; Kimura, Yoshihiro; Hokamura, Youichi; Yamabe, Hiroshige; Ueno, Kazuhiro [Kumamoto City Hospital (Japan)

    1998-01-01

    Twelve patients with stable angina and 12 patients with unstable angina underwent rest iodine-123-{beta}-methyl-iodophenyl-pentadecanoic acid (BMIPP), dipyridamole stress thallium scintigraphy and delayed thallium scintigraphy. In stable angina, sensitivity for detecting ischemic segments was higher in dipyridamole thallium (74%) than rest BMIPP (48%) images (p<0.05), but there was no significant difference between the 2 images in unstable angina. In unstable angina, the incidence of segments with higher defect scores on BMIPP images than on delayed thallium images and the opposite pattern was 27 and 5 (p<0.01). In stable angina, there was no difference. The mean defect score on BMIPP (6.3{+-}5.6) was higher than that on delayed thallium scintigraphy (2.9{+-}2.7) and it was almost the same as on the initial dipyridamole stress test (6.5{+-}5.2). In conclusion, BMIPP scintigraphy is safer and may be as useful in detecting myocardial ischemia in patients with unstable angina as thallium scintigraphy. (author)

  19. Scintigraphic differentiation between two forms of primary dysautonomia early after onset of autonomic dysfunction: value of cardiac and pulmonary iodine-123 MIBG uptake

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, M.J.; Juengling, F.D.; Krause, T.M. [Dept. of Nuclear Medicine, Freiburg University Hospital (Germany); Braune, S. [Dept. of Neurology, Freiburg University Hospital (Germany)

    2000-05-01

    Primary dysfunction of the autonomic nervous system can be observed in patients with Parkinson's disease and those with multiple system atrophy. However, the fate of the two diseases differs considerably and leads to different strategies for patient management. Differentiation of the two diseases currently requires a combination of several clinical and electrophysiological tests. First studies of myocardial innervation using iodine-123 metaiodobenzylguanidine (MIBG) indicated a possible role of scintigraphy for this purpose. An increase in the pulmonary uptake of {sup 123}I-MIBG has been reported in secondary dysautonomias. Whether sympathetic innervation of the lung is affected in primary dysautonomias is currently unknown. Therefore, cardiac and pulmonary uptake of {sup 123}I-MIBG was studied in 21 patients with Parkinson's disease, 7 patients with multiple system atrophy and 13 age- and sex-matched controls. Thoracic images were obtained in the anterior view 4 h after intravenous injection of 185 MBq {sup 123}I-MIBG, at which time the maximum neuronal uptake is reached. All patients with Parkinson's disease had significantly lower cardiac uptake of {sup 123}I-MIBG than patients with multiple system atrophy and controls. Sympathetic innervation of the lung was not affected in either disease. It is concluded that scintigraphy with {sup 123}I-MIBG appears to be a useful tool for differentiation between Parkinson's disease and multiple system atrophy early after onset of autonomic dysfunction. (orig.)

  20. Single photons, dileptons and hadrons from relativistic heavy ion ...

    Indian Academy of Sciences (India)

    The production of single photons in Pb+Pb collisions at the CERN SPS as measured by the WA98 experiment is analysed. A quark gluon plasma is assumed to be formed initially, which expands, cools, hadronizes, and undergoes freeze-out. A rich hadronic equation of state is used and the transverse expansion of the ...

  1. Single-photon source engineering using a Modal Method

    DEFF Research Database (Denmark)

    Gregersen, Niels

    Solid-state sources of single indistinguishable photons are of great interest for quantum information applications. The semiconductor quantum dot embedded in a host material represents an attractive platform to realize such a single-photon source (SPS). A near-unity efficiency, defined as the num...... nanowire SPSs...

  2. Waveguide-Coupled Superconducting Nanowire Single-Photon Detectors

    Science.gov (United States)

    Beyer, Andrew D.; Briggs, Ryan M.; Marsili, Francesco; Cohen, Justin D.; Meenehan, Sean M.; Painter, Oskar J.; Shaw, Matthew D.

    2015-01-01

    We have demonstrated WSi-based superconducting nanowire single-photon detectors coupled to SiNx waveguides with integrated ring resonators. This photonics platform enables the implementation of robust and efficient photon-counting detectors with fine spectral resolution near 1550 nm.

  3. Single-photon superradiance from a quantum dot

    DEFF Research Database (Denmark)

    Tighineanu, Petru; Daveau, Raphaël Sura; Lehmann, Tau Bernstorff

    2016-01-01

    We report on the observation of single-photon superradiance from an exciton in a semiconductor quantum dot. The confinement by the quantum dot is strong enough for it to mimic a two-level atom, yet sufficiently weak to ensure superradiance. The electrostatic interaction between the electron and t...

  4. Single photons, dileptons and hadrons from relativistic heavy ion ...

    Indian Academy of Sciences (India)

    Abstract. The production of single photons in Pb+Pb collisions at the CERN SPS as measured by the WA98 experiment is analysed. A quark gluon plasma is assumed to be formed initially, which expands, cools, hadronizes, and undergoes freeze-out. A rich hadronic equation of state is used and the transverse expansion of ...

  5. The physics of nanowire superconducting single-photon detectors

    NARCIS (Netherlands)

    Renema, Jelmer Jan

    2015-01-01

    We investigate the detection mechanism in superconducting single photon detectors via quantum detector tomography. We find that the detection event is caused by diffusion of quasiparticles from the absorption spot, combined with entrance of a vortex. Moreover, we investigate the behaviour of

  6. Deterministic teleportation using single-photon entanglement as a resource

    DEFF Research Database (Denmark)

    Björk, Gunnar; Laghaout, Amine; Andersen, Ulrik L.

    2012-01-01

    We outline a proof that teleportation with a single particle is, in principle, just as reliable as with two particles. We thereby hope to dispel the skepticism surrounding single-photon entanglement as a valid resource in quantum information. A deterministic Bell-state analyzer is proposed which...

  7. Investigation of the relationship between regression of hypertensive cardiac hypertrophy and improvement of cardiac sympathetic nervous dysfunction using iodine-123 metaiodobenzylguanidine myocardial imaging

    International Nuclear Information System (INIS)

    Morimoto, Satoshi; Terada, Koji; Keira, Natsuya; Satoda, Masahiko; Inoue, Keiji; Tatsukawa, Hirotaka; Katoh, Shuji; Ida, Kazunori; Sugihara, Hiroki; Takeda, Kazuo; Nakagawa, Masao

    1996-01-01

    Although many theories exist on the subject, the mechanisms responsible for a reduction of hypertensive cardiac hypertrophy in response to antihypertensive therapy are still unclear. In order to investigate the relationship between regression of hypertensive cardiac hypertrophy and cardiac nervous function, we studied ten patients with untreated essential hypertension (six men and four women, 62±12 years old). Both echocardiography and iodine-123 metaiodobenzylguanidine (MIBG) myocardial imaging were performed before and after antihypertensive therapy. Left ventricular mass (LVM) was significantly reduced in conjunction with the reduction of blood pressure following treatment. MIBG myocardial images showed that the heart-to-mediastinum activity ratio (H/M) was significantly increased while the washout ratio was significantly decreased. Patients were divided into two groups according to the ratio of the LVM values before and after therapy (LVM ratio). Patients with an LVM ratio of less than 0.75 were classified as group A and those with values higher than 0.75 as group B. Neither the change in blood pressure nor the length of treatment was significantly different between these two groups. On the other hand, both the increase in H/M and the decrease in the washout ratio were significantly greater in group A than in group B. These results indicate that an improvement in cardiac sympathetic nervous function may be related to the regression of hypertensive cardiac hypertrophy. Increasing the subject base in these studies and a more precise analysis of the relevance of the data obtained from MIBG myocardial images are recommended to clarify how changes in cardiac sympathetic nervous function relate to the regression of hypertensive cardiac hypertrophy. (orig.)

  8. Significance of retardation of abnormal uptake of iodine-123-beta-methyl-p-iodophenyl-pentadecanoic acid myocardial scintigraphy in patients with vasospastic angina

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Fumitaka; Hashimoto, Toshio; Uemura, Shiro; Kawamoto, Atsuhiko; Dohi, Kazuhiro [Nara Medical Univ., Kashihara (Japan); Matsushima, Akihiko

    2001-07-01

    This study investigated retardation of abnormal uptake of iodine-123-beta-methyl-p-iodophenyl-pentadecanoic acid (BMIPP) scintigraphy in patients with vasospastic angina. Twenty-three patients with vasospastic angina showed abnormal uptake of BMIPP before medical treatment and had coronary vasospasm induced by acetylcholine. The patients were divided into two groups according to uptake of BMIPP after medical treatment: retardation of abnormal uptake of BMIPP (Group R, n=4) and normal uptake of BMIPP (Group N, n=19). Frequency of chest pain, medical treatment and autonomic nervous activity were compared between the two groups. Furthermore, the frequency of chest pain and uptake of BMIPP in group R were obtained after intensive medical treatment. Autonomic nervous activity was evaluated by heart rate variability on Holter electrocardiography. Heart rate variability contained high-frequency elements (HF; 0.15-0.4 Hz) and low-frequency elements (LF; 0.04-0.15 Hz). LF/HF was estimated for sympathetic nervous activity and HF was estimated for parasympathetic nervous activity. Daytime and nighttime autonomic nervous activity were compared between the two groups. The frequency of chest pain was higher in Group R than in Group N (p<0.05). Medical treatment was not different between the two groups. Circadian variation of sympathetic and parasympathetic nervous activity were absent in Group R. During the nighttime, Group R showed higher sympathetic nervous activity (p<0.05) and lower parasympathetic nervous activity (p<0.01) than Group N. The frequency of chest pain was significantly lower after intensive medical treatment (p<0.05), and uptake of BMIPP returned to normal in Group R. We suspected that the disorder in autonomic nervous activity was more severe in Group R, and thus induced coronary vasospasm. Retardation of abnormal uptake of BMIPP in patients with vasospastic angina indicates poor control of coronary vasospasm. Uptake of BMIPP is useful in the evaluation of

  9. Fatty acid metabolic and perfusion abnormalities in hypertrophied myocardium assessed by dual tracer tomography using thallium-201 and iodine-123-beta-methylpentadecanoic acid

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hiroshi; Nakata, Tomoaki; Han, Shizui (Sapporo Medical Coll. (Japan)) (and others)

    Fatty acid and perfusion abnormalities associated with cardiac hypertrophy were investigated using dual tracer tomography with thallium and a cardiac metabolic tracer, 15-(p-iodophenyl)-3-R, S-methylpentadecanoic acid (BMIPP), in eight patients with hypertrophic cardiomyopathy (HCM) and in three with hypertension (HT). Thallium and BMIPP uptakes were scored and analyzed in 143 segments (13/heart) by comparison with the left ventricular wall thickness measured by two dimensional echocardiography. Complete agreement of both scores in HT patients was significantly higher than that in HCM patients (64% vs 24%, p<0.001), while a lower BMIPP uptake compared to that of thallium (mismatching) was observed more frequently in HCM than in HT patients (65% vs 31%, p<0.001). The wall thickness significantly (p<0.005) correlated with BMIPP uptake score. HCM patients showed a low BMIPP uptake in 22 hypertrophic segments (59%) and 15 non-hypertrophic segments (41%), and reduced BMIPP uptake in 29% hypertrophic segments, while HT patients showed just five segments with decreased BMIPP uptake of which 4 were non-hypertrophic and only one hypertrophic. The left ventricular ejection fraction assessed by radionuclide ventriculography was normal and no regional wall motion abnormality was detected in any patient by echocardiographic and scintigraphic studies. Metabolic abnormalities detected by the iodine-123-beta-methyl fatty acid analog in hypertrophic cardiomyopathy may be independent of thallium myocardial perfusion, regional wall motion, or the magnitude of cardiac hypertrophy, suggesting that fatty acid imaging may be useful in investigating the pathogenesis and subclinical abnormality of hypertrophic cardiomyopathy, and differentiation from secondary, induced cardiac hypertrophy. (author).

  10. Effects of aldose reductase inhibitor and vitamin B12 on myocardial uptake of iodine-123 metaiodobenzylguanidine in patients with non-insulin-dependent diabetes mellitus

    International Nuclear Information System (INIS)

    Utsunomiya, Keita; Narabayashi, Isamu; Tamura, Koji; Nakatani, Yuko; Saika, Yoshinori; Onishi, Satoshi; Kariyone, Shigeo

    1998-01-01

    This study was undertaken to examine the effects of aldose reductase inhibitor (ARI) and vitamin B 12 (VB12) on myocardial uptake of iodine-123 metaiodobenzylguanidine (MIBG) in patients with diabetic autonomic disorder. Myocardial scintigraphy using 123 I-MIBG was performed on 20 healthy volunteers (controls) and 56 patients with non-insulin-dependent diabetes mellitus (NIDDM), in order to obtain the heart/mediastinum ratio in the initial (HMi) and the delayed images (HMd), and the washout rate (%WR). Thirty-four of the 56 NIDDM patients could be diagnosed as having diabetic autonomic disorder by evaluating their scintigraphic findings in comparison with the controls. Seventeen of these 34 patients received 150 mg/day of epalrestat (ARI group) in three divided doses before meals, and the other 17 received 1.5 mg/day of mecobalamin (VB12 group) in three divided doses after meals, for 3-5 months. According to the presence or absence of clinical symptoms of autonomic or peripheral somatic nerve disorder, the patients were subclassified into four groups. group 1=patients, with autonomic symptoms or somatosensory disorder in the ARI group; group 2=patients without autonomic symptoms or somatosensory disorder in the ARI group; group 3=patients with autonomic symptoms or somatosensory disorder in the VB12 group; and group 4=patients without autonomic symptoms or somatosensory disorder in the VB12 group. After completion of the treatment, myocardial scintigraphy was performed again. Comparing the results obtained before and after the treatment, it was seen that ARI improved only the HMi in group 1 (P=0.046), whereas VB12 significantly improved HMi in the group 3 (P=0.018) and HMi, HMd and %WR in group 4 (P=0.043, P=0.018 and P=0.043, respectively). We conclude that VB12 is more efficacious than ARI in the treatment of diabetic cardiovascular autonomic disorder. (orig.)

  11. Evaluation of therapy for dilated cardiomyopathy with heart failure by iodine-123 metaiodobenzyl-guanidine imaging. Comparison with heart rate variability power spectral analysis

    International Nuclear Information System (INIS)

    Li, Shou-lin; Ikeda, Jun; Takita, Tamotsu; Sekiguchi, Yohei; Demachi, Jun; Chikama, Hisao; Goto, Atsushi; Shirato, Kunio

    1998-01-01

    The relationship between the myocardial uptake of iodine-123 metaiodobenzylguanidine ( 123 I-MIBG) and heart rate variability parameters has not been determined. This study determined the relationship between the change in myocardial uptake of 123 I-MIBG and improvement in left ventricular function after treatment, to determine the usefulness of 123 I-MIBG imaging to assess the effect of therapy on heart failure due to dilated cardiomyopathy (DCM). 123 I-MIBG imaging and power spectral analysis of heart rate variability were performed before and after treatment in 17 patients with heart failure due to DCM. The following parameters were compared before and after treatment: New York Heart Association (NYHA) functional class, radiographic cardiothoracic ratio (CTR), blood pressure, echocardiographic data (left ventricular end-systolic (LVDs) and end-diastolic (LVDd) diameters, left ventricular ejection fraction (LVEF)), plasma concentrations of norepinephrine and epinephrine, heart rate variability power spectral analysis data (mean low frequency (MLF) and high frequency power (MHF)) and the myocardium to mediastinum activity ratio (MYO/M) obtained in early and late images, and washout rate calculated by anterior planar imaging of 123 I-MIBG. The NYHA functional class, LVEF, LVDs, CTR, MLF and MHF improved after treatment. Early MYO/M and late MYO/M improved after treatment. The rate of increase in late MYO/M was positively correlated with the rate of improvement of LVEF after treatment. Furthermore, the late MYO/M was negatively correlated with MLF. Washout rate revealed no correlation with hemodynamic parameters. These findings suggest that late MYO/M is more useful than washout rate to assess the effect of treatment on heart failure due to DCM. Furthermore, the 123 I-MIBG imaging and heart rate variability parameters are useful to assess the autonomic tone in DCM with heart failure. (author)

  12. Significance of retardation of abnormal uptake of iodine-123-beta-methyl-p-iodophenyl-pentadecanoic acid myocardial scintigraphy in patients with vasospastic angina

    International Nuclear Information System (INIS)

    Inoue, Fumitaka; Hashimoto, Toshio; Uemura, Shiro; Kawamoto, Atsuhiko; Dohi, Kazuhiro; Matsushima, Akihiko

    2001-01-01

    This study investigated retardation of abnormal uptake of iodine-123-beta-methyl-p-iodophenyl-pentadecanoic acid (BMIPP) scintigraphy in patients with vasospastic angina. Twenty-three patients with vasospastic angina showed abnormal uptake of BMIPP before medical treatment and had coronary vasospasm induced by acetylcholine. The patients were divided into two groups according to uptake of BMIPP after medical treatment: retardation of abnormal uptake of BMIPP (Group R, n=4) and normal uptake of BMIPP (Group N, n=19). Frequency of chest pain, medical treatment and autonomic nervous activity were compared between the two groups. Furthermore, the frequency of chest pain and uptake of BMIPP in group R were obtained after intensive medical treatment. Autonomic nervous activity was evaluated by heart rate variability on Holter electrocardiography. Heart rate variability contained high-frequency elements (HF; 0.15-0.4 Hz) and low-frequency elements (LF; 0.04-0.15 Hz). LF/HF was estimated for sympathetic nervous activity and HF was estimated for parasympathetic nervous activity. Daytime and nighttime autonomic nervous activity were compared between the two groups. The frequency of chest pain was higher in Group R than in Group N (p<0.05). Medical treatment was not different between the two groups. Circadian variation of sympathetic and parasympathetic nervous activity were absent in Group R. During the nighttime, Group R showed higher sympathetic nervous activity (p<0.05) and lower parasympathetic nervous activity (p<0.01) than Group N. The frequency of chest pain was significantly lower after intensive medical treatment (p<0.05), and uptake of BMIPP returned to normal in Group R. We suspected that the disorder in autonomic nervous activity was more severe in Group R, and thus induced coronary vasospasm. Retardation of abnormal uptake of BMIPP in patients with vasospastic angina indicates poor control of coronary vasospasm. Uptake of BMIPP is useful in the evaluation of

  13. Protecting single-photon entanglement with practical entanglement source

    Science.gov (United States)

    Zhou, Lan; Ou-Yang, Yang; Wang, Lei; Sheng, Yu-Bo

    2017-06-01

    Single-photon entanglement (SPE) is important for quantum communication and quantum information processing. However, SPE is sensitive to photon loss. In this paper, we discuss a linear optical amplification protocol for protecting SPE. Different from the previous protocols, we exploit the practical spontaneous parametric down-conversion (SPDC) source to realize the amplification, for the ideal entanglement source is unavailable in current quantum technology. Moreover, we prove that the amplification using the entanglement generated from SPDC source as auxiliary is better than the amplification assisted with single photons. The reason is that the vacuum state from SPDC source will not affect the amplification, so that it can be eliminated automatically. This protocol may be useful in future long-distance quantum communications.

  14. Cooling in the single-photon regime of optomechanics

    Science.gov (United States)

    Nunnenkamp, Andreas; Borkje, Kjetil; Girvin, Steven

    2012-02-01

    Optomechanics experiments are rapidly approaching the regime where the radiation pressure of a single photon displaces the mechanical oscillator by more than its zero-point uncertainty. We show that in this limit the power spectrum has multiple sidebands and that the cavity response has several resonances in the resolved-sideband limit [Phys. Rev. Lett. 107, 063602 (2011)]. We then discuss how red-sideband cooling is modified in this nonlinear regime. Using Fermi's Golden rule we calculate the transition rates induced by the optical drive. In the resolved-sideband limit we find multiple cooling resonances for strong single-photon coupling. They lead to non-thermal steady states and are accompanied by multiple mechanical sidebands in the optical output spectrum. Our study provides the tools to detect and take advantage of this novel regime of optomechanics.

  15. Multi-group dynamic quantum secret sharing with single photons

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hongwei [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Ma, Haiqiang, E-mail: hqma@bupt.edu.cn [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Wei, Kejin [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Yang, Xiuqing [School of Science, Beijing Jiaotong University, Beijing 100044 (China); Qu, Wenxiu; Dou, Tianqi; Chen, Yitian; Li, Ruixue; Zhu, Wu [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China)

    2016-07-15

    In this letter, we propose a novel scheme for the realization of single-photon dynamic quantum secret sharing between a boss and three dynamic agent groups. In our system, the boss can not only choose one of these three groups to share the secret with, but also can share two sets of independent keys with two groups without redistribution. Furthermore, the security of communication is enhanced by using a control mode. Compared with previous schemes, our scheme is more flexible and will contribute to a practical application. - Highlights: • A multi-group dynamic quantum secret sharing with single photons scheme is proposed. • Any one of the groups can be chosen to share secret through controlling the polarization of photons. • Two sets of keys can be shared simultaneously without redistribution.

  16. Advanced time-correlated single photon counting applications

    CERN Document Server

    Becker, Wolfgang

    2015-01-01

    This book is an attempt to bridge the gap between the instrumental principles of multi-dimensional time-correlated single photon counting (TCSPC) and typical applications of the technique. Written by an originator of the technique and by sucessful users, it covers the basic principles of the technique, its interaction with optical imaging methods and its application to a wide range of experimental tasks in life sciences and clinical research. The book is recommended for all users of time-resolved detection techniques in biology, bio-chemistry, spectroscopy of live systems, live cell microscopy, clinical imaging, spectroscopy of single molecules, and other applications that require the detection of low-level light signals at single-photon sensitivity and picosecond time resolution.

  17. Directional emission of single photons from small atomic samples

    DEFF Research Database (Denmark)

    Miroshnychenko, Yevhen; V. Poulsen, Uffe; Mølmer, Klaus

    2013-01-01

    We provide a formalism to describe deterministic emission of single photons with tailored spatial and temporal profiles from a regular array of multi-level atoms. We assume that a single collective excitation is initially shared by all the atoms in a metastable atomic state, and that this state i...... is coupled by a classical laser field to an optically excited state which rapidly decays to the ground atomic state. Our model accounts for the different field polarization components via re-absorption and emission of light by the Zeeman manifold of optically excited states.......We provide a formalism to describe deterministic emission of single photons with tailored spatial and temporal profiles from a regular array of multi-level atoms. We assume that a single collective excitation is initially shared by all the atoms in a metastable atomic state, and that this state...

  18. Semi-quantum Dialogue Based on Single Photons

    Science.gov (United States)

    Ye, Tian-Yu; Ye, Chong-Qiang

    2018-02-01

    In this paper, we propose two semi-quantum dialogue (SQD) protocols by using single photons as the quantum carriers, where one requires the classical party to possess the measurement capability and the other does not have this requirement. The security toward active attacks from an outside Eve in the first SQD protocol is guaranteed by the complete robustness of present semi-quantum key distribution (SQKD) protocols, the classical one-time pad encryption, the classical party's randomization operation and the decoy photon technology. The information leakage problem of the first SQD protocol is overcome by the classical party' classical basis measurements on the single photons carrying messages which makes him share their initial states with the quantum party. The security toward active attacks from Eve in the second SQD protocol is guaranteed by the classical party's randomization operation, the complete robustness of present SQKD protocol and the classical one-time pad encryption. The information leakage problem of the second SQD protocol is overcome by the quantum party' classical basis measurements on each two adjacent single photons carrying messages which makes her share their initial states with the classical party. Compared with the traditional information leakage resistant QD protocols, the advantage of the proposed SQD protocols lies in that they only require one party to have quantum capabilities. Compared with the existing SQD protocol, the advantage of the proposed SQD protocols lies in that they only employ single photons rather than two-photon entangled states as the quantum carriers. The proposed SQD protocols can be implemented with present quantum technologies.

  19. Heterodyne spectroscopy with superconducting single-photon detector

    International Nuclear Information System (INIS)

    Lobanov, Yu.V.; Shcherbatenko, M.L.; Semenov, A.V.; Kovalyuk, V.V.; Korneev, A.A.; Goltsman, G.N.

    2017-01-01

    We demonstrate successful operation of a Superconducting Single Photon Detector (SSPD) as the core element in a heterodyne receiver. Irradiating the SSPD by both a local oscillator power and signal power simultaneously, we observed beat signal at the intermediate frequency of a few MHz. Gain bandwidth was found to coincide with the detector single pulse width, where the latter depends on the detector kinetic inductance, determined by the superconducting nanowire length.

  20. On the scalar electron mass limit from single photon experiments

    International Nuclear Information System (INIS)

    Grivaz, J.F.

    1987-03-01

    We discuss how the 90% C.L. lower limit on the mass of the scalar electron, as extracted from the single photon experiments, is affected by the way the background from radiative neutrino pair production is handled. We argue that some of the results presented at the Berkeley conference are overoptimistic, and that the mass lower limit is 65 GeV rather than the advertized value of 84 GeV, for the case of degenerate scalar electrons with massless photinos

  1. Novel single photon sources for new generation of quantum communications

    Science.gov (United States)

    2017-06-13

    state single photon sources that was published in Nature Photonics in October 2016. 15. SUBJECT TERMS diamond color center, diamond, AOARD 16. SECURITY...platform for quantum emitters. We developed means to increase their density, developed basic methods to engineer them, and demonstrate coupling to...manipulation of a silicon vacancy color cent er in a nanodiamond. We demonstrate ultra fast coherent control of a photon, that make s this defect

  2. Fabrication and test of Superconducting Single Photon Detectors

    International Nuclear Information System (INIS)

    Leoni, R.; Mattioli, F.; Castellano, M.G.; Cibella, S.; Carelli, P.; Pagano, S.; Perez de Lara, D.; Ejrnaes, M.; Lisitskyi, M.P.; Esposito, E.; Cristiano, R.; Nappi, C.

    2006-01-01

    We report here on the state of our fabrication process for Superconducting Single Photon Detectors (SSPDs). We have fabricated submicrometer SSPD structures by electron beam lithography using very thin (10 nm) NbN films deposited by DC-magnetron sputtering on different substrates and at room substrate temperature. The structures show a fast optical response (risetime <500 ps limited by readout electronics) and interesting self-resetting features

  3. Single-photon ultrashort-lived radionuclides: symposium proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Paras, P.; Thiessen, J.W. (eds.)

    1985-01-01

    The purpose was to define the current role and state-of-the-art regarding the development, clinical applications, and usefulness of generator-produced single-photon ultrashort-lived radionuclides (SPUSLR's) and to predict their future impact on medicine. Special emphasis was placed on the generator production of iridium-191, gold-195, and krypton-81. This report contains expanded summaries of the included papers. (ACR)

  4. Coherent single-photon absorption by single emitters coupled to 1D nanophotonic waveguides

    DEFF Research Database (Denmark)

    Chen, Yuntian; Wubs, Martijn; Mørk, Jesper

    2012-01-01

    We have derived an efficient model that allows calculating the dynamical single-photon absorption of an emitter coupled to a waveguide. We suggest a novel and simple structure that leads to strong single-photon absorption.......We have derived an efficient model that allows calculating the dynamical single-photon absorption of an emitter coupled to a waveguide. We suggest a novel and simple structure that leads to strong single-photon absorption....

  5. Differential distribution of striatal [123I]β-CIT in Parkinson's disease and progressive supranuclear palsy, evaluated with single-photon emission tomography

    International Nuclear Information System (INIS)

    Messa, C.; Volonte, M.A.; Fazio, F.; Zito, F.; Carpinelli, A.; D'Amico, A.; Rizzo, G.; Moresco, R.M.; Paulesu, E.; Franceschi, M.; Lucignani, G.

    1998-01-01

    Functional imaging of the presynaptic dopaminergic activity using single-photon emission tomography (SPET) and iodine-123 labelled 2-β-carboxymethoxy-3-β-(4-iodophenyl)tropane ([ 123 I]β-CIT) is important for the assessment of disease severity and progression in patients with Parkinson's disease (PD). However, its capability to discriminate between different extrapyramidal disorders has not yet been assessed. The aim of this study was to evaluate the possibility of differentiating patients with PD and with progressive supranuclear palsy (PSP) by means of this method. The distribution of [ 123 I]β-CIT in the basal ganglia was assessed in six normal subjects, 13 petients with PD and five patients with PSP in whom the disease was mild. SPET images were obtained 24±2 h after i.v. injection of the tracer using a brain-dedicated system (CERASPECT). MR and SPET images were co-registered in four normal subjects and used to define a standard set of 16 circular regions of interest (ROIs) on the slice showing the highest striatal activity. The basal ganglia ROIs corresponded to (1) the head of caudate, (2) a region of transition between the head of caudate and the anterior putamen, (3) the anterior putamen and (4) the posterior putamen. A ratio of specific to non-displaceable striatal uptake was calculated normalising the activity of the basal ganglia ROIs to that of the occipital cortex (V3''). ANOVA revealed a global reduction of V3'' in all ROIs of PD and PSP patients compared with normal controls (P 123 I]β-CIT distribution in discrete striatal areas provides information on the relative caudate-putamen damage, with different values being obtained in patients clinically diagnosed as having either PD or PSP. (orig.)

  6. Initial evaluation of 123I-5-I-R91150, a selective 5-HT2Aligand for single-photon emission tomography, in healthy human subjects

    International Nuclear Information System (INIS)

    Busatto, G.F.; Pilowsky, L.S.; Costa, D.C.; Mertens, J.; Terriere, D.; Ell, P.J.; Mulligan, R.; Travis, M.J.; Leysen, J.E.; Lui, D.; Gacinovic, S.; Waddington, W.; Lingford-Hughes, A.; Kerwin, R.W.

    1997-01-01

    The mapping of 5-HT 2 receptors in the brain using functional imaging techniques has been limited by a relative lack of selective radioligands. Iodine-123 labelled 4-amino-N-[1-[3-(4-fluorophenoxy)propyl]-4-methyl-4-piperidinyl]-5-iodo-2-methox ybenzamide ( 123 I-5-I-R91150 or 123 I-R93274) is a new ligand for single-photon emission tomography (SPET), with high affinity and selectivity for 5-HT 2A receptors. This study reports on preliminary 123 I-5-I-R91150 SPET, whole-body and blood distribution findings in five healthy human volunteers. Maximal brain uptake was approximately 2% of total body counts at 180 min post injection (p.i.). Dynamic SPET sequences were acquired with the brain-dedicated, single-slice multi-detector system SME-810 over 200 min p.i. Early peak uptake (at 5 min p.i.) was seen in the cerebellum, a region free from 5HT 2A receptors. In contrast, radioligand binding in the frontal cortex increased steadily over time, up to a peak at approximately 100-120 min p.i. Frontal cortex-cerebellum activity ratios reached values of 1.4, and remained stable from approximately 100 min p.i. onwards. Multi-slice SPET sequences showed a pattern of regional variation of binding compatible with the autoradiographic data on the distribution of 5-HT 2A receptors in humans (cerebral cortex >striatum >cerebellum). These findings suggest that 123 I-5-I-R91150 may be used for the imaging of 5-HT 2A receptors in the living human brain with SPET. (orig.). With 4 figs., 2 tabs

  7. Use of iodine-123 metaiodobenzylguanidine scintigraphy to assess cardiac sympathetic denervation and the impact of hypertension in patients with non-insulin-dependent diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Koji; Nakatani, Yuko; Onishi, Satoshi [Dept. of Internal Medicine, Keihanna Hospital, Hirakata City, Osaka (Japan); Utsunomiya, Keita; Saika, Yoshinori [Dept. of Radiology, Keihanna Hospital, Hirakata City (Japan); Iwasaka, Toshiji [Cardiovascular Center, Kansai Medical University, Osaka (Japan)

    1999-10-01

    The objectives of this clinical study using iodine-123 metaiodobenzylguanidine (MIBG) scintigraphy were (a) to evaluate cardiac sympathetic denervation in non-insulin-dependent diabetes mellitus (NIDDM) patients with and without hypertension and (b) to investigate the relation between cardiac sympathetic denervation and prognosis in NIDDM patients. We compared clinical characteristics and MIBG data [heart to mediastinum (H/M) ratio and % washout rate (WR)] in a control group and NIDDM patients with and without hypertension. MIBG scintigraphy was performed in 11 controls and 82 NIDDM patients without overt cardiovascular disease except for hypertension (systolic blood pressure {>=}140 and/or diastolic blood pressure {>=}90 mmHg). After MIBG examination, blood pressure was measured regularly in all NIDDM patients. There were significant differences between 65 normotensive and 17 hypertensive NIDDM patients with respect to age (55{+-}11 vs 63{+-}12 years, respectively, P<0.05), prevalence of diabetic retinopathy (12% vs 35%, respectively, P<0.05) and systolic blood pressure (120{+-}12 vs 145{+-}16 mmHg, respectively, P<0.001). The H/M ratio in hypertensive NIDDM patients was significantly lower than in the control group (1.81{+-}0.29 vs 2.27{+-}0.20, respectively, P<0.01). During the follow-up period (18{+-} 12 months), 17 NIDDM patients newly developed hypertension after MIBG examination. There were no significant differences in their clinical characteristics compared with persistently normotensive or hypertensive NIDDM patients. %WR in patients with new onset hypertension was significantly higher than in the control group (30.88%{+-}16.87% vs 12.89%{+-}11.94%, respectively, P<0.05). Moreover, in these patients %WR correlated with duration from the date of MIBG scintigraphy to the onset of hypertension (r=-0.512, P<0.05). Five NIDDM patients died during the follow-up period (four newly hypertensive patients and one normotensive patient). There were significant

  8. Optimised quantum hacking of superconducting nanowire single-photon detectors.

    Science.gov (United States)

    Tanner, Michael G; Makarov, Vadim; Hadfield, Robert H

    2014-03-24

    We explore bright-light control of superconducting nanowire single-photon detectors (SNSPDs) in the shunted configuration (a practical measure to avoid latching). In an experiment, we simulate an illumination pattern the SNSPD would receive in a typical quantum key distribution system under hacking attack. We show that it effectively blinds and controls the SNSPD. The transient blinding illumination lasts for a fraction of a microsecond and produces several deterministic fake clicks during this time. This attack does not lead to elevated timing jitter in the spoofed output pulse, and hence does not introduce significant errors. Five different SNSPD chip designs were tested. We consider possible countermeasures to this attack.

  9. Phonon number measurements using single photon opto-mechanics

    International Nuclear Information System (INIS)

    Basiri-Esfahani, S; Akram, U; Milburn, G J

    2012-01-01

    We describe a system composed of two coupled optical cavity modes with a coupling modulated by a bulk mechanical resonator. In addition, one of the cavity modes is irreversibly coupled to a single photon source. Our scheme is an opto-mechanical realization of the Jaynes–Cummings model where the qubit is a dual rail optical qubit while the bosonic degree of freedom is a matter degree of freedom realized as the bulk mechanical excitation. We show the possibility of engineering phonon number states of the mechanical oscillator in such a system by computing the conditional state of the mechanics after successive photon counting measurements. (paper)

  10. Single-photon-level quantum memory at room temperature.

    Science.gov (United States)

    Reim, K F; Michelberger, P; Lee, K C; Nunn, J; Langford, N K; Walmsley, I A

    2011-07-29

    Room-temperature, easy-to-operate quantum memories are essential building blocks for future long distance quantum information networks operating on an intercontinental scale, because devices like quantum repeaters, based on quantum memories, will have to be deployed in potentially remote, inaccessible locations. Here we demonstrate controllable, broadband and efficient storage and retrieval of weak coherent light pulses at the single-photon level in warm atomic cesium vapor using the robust far off-resonant Raman memory scheme. We show that the unconditional noise floor of this technically simple quantum memory is low enough to operate in the quantum regime, even in a room-temperature environment.

  11. Characterization of parallel superconducting nanowire single photon detectors

    International Nuclear Information System (INIS)

    Ejrnaes, M; Casaburi, A; Pagano, S; Cristiano, R; Quaranta, O; Marchetti, S; Gaggero, A; Mattioli, F; Leoni, R

    2009-01-01

    Superconducting nanowire single photon detectors (SNSPDs) have been realized using an innovative parallel wire configuration. This configuration allows, at the same time, a large detection area and a fast response, with the additional advantage of large signal amplitudes. The detectors have been thoroughly characterized in terms of signal properties (amplitude, risetime and falltime), detector operation (latching and not latching) and quantum efficiency (at 850 nm). It has been shown that the parallel SNSPD is able to provide significantly higher maximum count rates for large area SNSPDs than meandered SNSPDs. Through a proper parallel wire configuration the increase in maximum count rate can be obtained without latching problems.

  12. Characterization of parallel superconducting nanowire single photon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Ejrnaes, M; Casaburi, A; Pagano, S; Cristiano, R [CNR-Istituto di Cibernetica ' E Caianiello' , 80078 Pozzuoli (Namibia) (Italy); Quaranta, O; Marchetti, S [Dipartimento di Fisica ' E R Caianiello' , Universita di Salerno, 84081 Baronissi (Italy); Gaggero, A; Mattioli, F; Leoni, R [CNR-Istituto di Fotonica e Nanotecnologie, 00156 Roma (Italy)

    2009-05-15

    Superconducting nanowire single photon detectors (SNSPDs) have been realized using an innovative parallel wire configuration. This configuration allows, at the same time, a large detection area and a fast response, with the additional advantage of large signal amplitudes. The detectors have been thoroughly characterized in terms of signal properties (amplitude, risetime and falltime), detector operation (latching and not latching) and quantum efficiency (at 850 nm). It has been shown that the parallel SNSPD is able to provide significantly higher maximum count rates for large area SNSPDs than meandered SNSPDs. Through a proper parallel wire configuration the increase in maximum count rate can be obtained without latching problems.

  13. Optimised quantum hacking of superconducting nanowire single-photon detectors

    Science.gov (United States)

    Tanner, Michael G.; Makarov, Vadim; Hadfield, Robert H.

    2014-03-01

    We explore bright-light control of superconducting nanowire single-photon detectors (SNSPDs) in the shunted configuration (a practical measure to avoid latching). In an experiment, we simulate an illumination pattern the SNSPD would receive in a typical quantum key distribution system under hacking attack. We show that it effectively blinds and controls the SNSPD. The transient blinding illumination lasts for a fraction of a microsecond and produces several deterministic fake clicks during this time. This attack does not lead to elevated timing jitter in the spoofed output pulse, and hence does not introduce significant errors. Five different SNSPD chip designs were tested. We consider possible countermeasures to this attack.

  14. Quasi free mechanism in single photon double ionization of helium

    Energy Technology Data Exchange (ETDEWEB)

    Schoeffler, Markus; Stuck, Christian [Frankfurt Univ., Frankfurt am Main (Germany). Inst. fuer Kernphysik; Lawrence Berkeley National Lab, Berkeley, CA (United States); Jahnke, Till; Waitz, Markus; Trinter, Florian; Lenz, Ute; Schmidt-Boecking, Horst; Doerner, Reinhard [Frankfurt Univ., Frankfurt am Main (Germany). Inst. fuer Kernphysik; Jones, Mathew; Landers, Allen [Auburn University, Auburn, AL (United States); Belkacem, Ali; Weber, Thorsten [Lawrence Berkeley National Lab, Berkeley, CA (United States); Cocke, Lew [Kansas State University, Manhattan, KS (United States)

    2012-07-01

    Double ionization of Helium by a single photon is widely believed to proceed through two mechanisms: knock-off (TS1) or shake-off, with the last one dominating at high photon energies. A new mechanism, termed ''Quasi Free Mechanism'' (QFM) was predicted 35 years ago by Amusia and coworkers, but escaped experimental observation till today. Here we provide the first proof of this mechanism using 800 eV photons from the Advanced Light Source. Fragments (electrons and ions) were measured in coincidence using momentum spectroscopy (COLTRIMS). He{sup (}2+) ions with zero momentum were found - the fingerprint for the QFM.

  15. Heralded noiseless amplification for single-photon entangled state with polarization feature

    Science.gov (United States)

    Wang, Dan-Dan; Jin, Yu-Yu; Qin, Sheng-Xian; Zu, Hao; Zhou, Lan; Zhong, Wei; Sheng, Yu-Bo

    2018-03-01

    Heralded noiseless amplification is a promising method to overcome the transmission photon loss in practical noisy quantum channel and can effectively lengthen the quantum communication distance. Single-photon entanglement is an important resource in current quantum communications. Here, we construct two single-photon-assisted heralded noiseless amplification protocols for the single-photon two-mode entangled state and single-photon three-mode W state, respectively, where the single-photon qubit has an arbitrary unknown polarization feature. After the amplification, the fidelity of the single-photon entangled state can be increased, while the polarization feature of the single-photon qubit can be well remained. Both the two protocols only require the linear optical elements, so that they can be realized under current experimental condition. Our protocols may be useful in current and future quantum information processing.

  16. Mitigating radiation damage of single photon detectors for space applications

    Energy Technology Data Exchange (ETDEWEB)

    Anisimova, Elena; Higgins, Brendon L.; Bourgoin, Jean-Philippe [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada); Cranmer, Miles [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); Choi, Eric [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); Magellan Aerospace, Ottawa, ON (Canada); Hudson, Danya; Piche, Louis P.; Scott, Alan [Honeywell Aerospace (formerly COM DEV Ltd.), Ottawa, ON (Canada); Makarov, Vadim [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada); University of Waterloo, Department of Electrical and Computer Engineering, Waterloo, ON (Canada); Jennewein, Thomas [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada); Canadian Institute for Advanced Research, Quantum Information Science Program, Toronto, ON (Canada)

    2017-12-15

    Single-photon detectors in space must retain useful performance characteristics despite being bombarded with sub-atomic particles. Mitigating the effects of this space radiation is vital to enabling new space applications which require high-fidelity single-photon detection. To this end, we conducted proton radiation tests of various models of avalanche photodiodes (APDs) and one model of photomultiplier tube potentially suitable for satellite-based quantum communications. The samples were irradiated with 106 MeV protons at doses approximately equivalent to lifetimes of 0.6, 6, 12 and 24 months in a low-Earth polar orbit. Although most detection properties were preserved, including efficiency, timing jitter and afterpulsing probability, all APD samples demonstrated significant increases in dark count rate (DCR) due to radiation-induced damage, many orders of magnitude higher than the 200 counts per second (cps) required for ground-to-satellite quantum communications. We then successfully demonstrated the mitigation of this DCR degradation through the use of deep cooling, to as low as -86 C. This achieved DCR below the required 200 cps over the 24 months orbit duration. DCR was further reduced by thermal annealing at temperatures of +50 to +100 C. (orig.)

  17. Single-photon imaging in complementary metal oxide semiconductor processes

    Science.gov (United States)

    Charbon, E.

    2014-01-01

    This paper describes the basics of single-photon counting in complementary metal oxide semiconductors, through single-photon avalanche diodes (SPADs), and the making of miniaturized pixels with photon-counting capability based on SPADs. Some applications, which may take advantage of SPAD image sensors, are outlined, such as fluorescence-based microscopy, three-dimensional time-of-flight imaging and biomedical imaging, to name just a few. The paper focuses on architectures that are best suited to those applications and the trade-offs they generate. In this context, architectures are described that efficiently collect the output of single pixels when designed in large arrays. Off-chip readout circuit requirements are described for a variety of applications in physics, medicine and the life sciences. Owing to the dynamic nature of SPADs, designs featuring a large number of SPADs require careful analysis of the target application for an optimal use of silicon real estate and of limited readout bandwidth. The paper also describes the main trade-offs involved in architecting such chips and the solutions adopted with focus on scalability and miniaturization. PMID:24567470

  18. Automated Characterization of Single-Photon Avalanche Photodiode

    Directory of Open Access Journals (Sweden)

    Aina Mardhiyah M. Ghazali

    2012-01-01

    Full Text Available We report an automated characterization of a single-photon detector based on commercial silicon avalanche photodiode (PerkinElmer C30902SH. The photodiode is characterized by I-V curves at different illumination levels (darkness, 10 pW and 10 µW, dark count rate and photon detection efficiency at different bias voltages. The automated characterization routine is implemented in C++ running on a Linux computer. ABSTRAK: Kami melaporkan pencirian pengesan foton tunggal secara automatik berdasarkan kepada diod foto runtuhan silikon (silicon avalanche photodiode (PerkinElmer C30902SH komersial. Pencirian  diod foto adalah berdasarkan kepada plot arus-voltan (I-V pada tahap pencahayaan yang berbeza (kelam - tanpa cahaya, 10pW, dan 10µW, kadar bacaan latar belakang, kecekapan pengesanan foton pada voltan picuan yang berbeza. Pengaturcaraan C++ digunakan di dalam rutin pencirian automatik melalui komputer dengan sistem pengendalian LINUX.KEYWORDS: avalanche photodiode (APD; single photon detector; photon counting; experiment automation

  19. Doped niobium superconducting nanowire single-photon detectors

    Science.gov (United States)

    Jia, Tao; Kang, Lin; Zhang, Labao; Zhao, Qingyuan; Gu, Min; Qiu, Jian; Chen, Jian; Jin, Biaobing

    2014-09-01

    We designed and fabricated a special doped niobium (Nb*) superconducting nanowire single-photon detector (SNSPD) on MgO substrate. The superconductivity of this ultra-thin Nb* film was further improved by depositing an ultra-thin aluminum nitride protective layer on top. Compared with traditional Nb films, Nb* films present higher T C and J C. We investigated the dependence of the characteristics of devices, such as cut-off wavelength, response bandwidth, and temperature, on their geometrical dimensions. Results indicate that reduction in both the width and thickness of Nb* nanowires extended the cut-off wavelength and improved the sensitivity. The Nb* SNSPD (50 nm width and 4.5 nm thickness) exhibited single-photon sensitivities at 1,310, 1,550, and 2,010 nm. We also demonstrated an enhancement in the detection efficiency by a factor of 10 in its count rate by lowering the working temperature from 2.26 K to 315 mK.

  20. Molecular single photon double K-shell ionization

    International Nuclear Information System (INIS)

    Penent, F.; Nakano, M.; Tashiro, M.; Grozdanov, T.P.; Žitnik, M.; Carniato, S.; Selles, P.; Andric, L.; Lablanquie, P.; Palaudoux, J.; Shigemasa, E.; Iwayama, H.; Hikosaka, Y.; Soejima, K.; Suzuki, I.H.; Kouchi, N.; Ito, K.

    2014-01-01

    We have studied single photon double K-shell ionization of small molecules (N 2 , CO, C 2 H 2n (n = 1–3), …) and the Auger decay of the resulting double core hole (DCH) molecular ions thanks to multi-electron coincidence spectroscopy using a magnetic bottle time-of-flight spectrometer. The relative cross-sections for single-site (K −2 ) and two-site (K −1 K −1 ) double K-shell ionization with respect to single K-shell (K −1 ) ionization have been measured that gives important information on the mechanisms of single photon double ionization. The spectroscopy of two-site (K −1 K −1 ) DCH states in the C 2 H 2n (n = 1–3) series shows important chemical shifts due to a strong dependence on the C-C bond length. In addition, the complete cascade Auger decay following single site (K −2 ) ionization has been obtained

  1. Use of iodine-123 metaiodobenzylguanidine scintigraphy to assess cardiac sympathetic denervation and the impact of hypertension in patients with non-insulin-dependent diabetes mellitus

    International Nuclear Information System (INIS)

    Tamura, Koji; Nakatani, Yuko; Onishi, Satoshi; Utsunomiya, Keita; Saika, Yoshinori; Iwasaka, Toshiji

    1999-01-01

    The objectives of this clinical study using iodine-123 metaiodobenzylguanidine (MIBG) scintigraphy were (a) to evaluate cardiac sympathetic denervation in non-insulin-dependent diabetes mellitus (NIDDM) patients with and without hypertension and (b) to investigate the relation between cardiac sympathetic denervation and prognosis in NIDDM patients. We compared clinical characteristics and MIBG data [heart to mediastinum (H/M) ratio and % washout rate (WR)] in a control group and NIDDM patients with and without hypertension. MIBG scintigraphy was performed in 11 controls and 82 NIDDM patients without overt cardiovascular disease except for hypertension (systolic blood pressure ≥140 and/or diastolic blood pressure ≥90 mmHg). After MIBG examination, blood pressure was measured regularly in all NIDDM patients. There were significant differences between 65 normotensive and 17 hypertensive NIDDM patients with respect to age (55±11 vs 63±12 years, respectively, P<0.05), prevalence of diabetic retinopathy (12% vs 35%, respectively, P<0.05) and systolic blood pressure (120±12 vs 145±16 mmHg, respectively, P<0.001). The H/M ratio in hypertensive NIDDM patients was significantly lower than in the control group (1.81±0.29 vs 2.27±0.20, respectively, P<0.01). During the follow-up period (18± 12 months), 17 NIDDM patients newly developed hypertension after MIBG examination. There were no significant differences in their clinical characteristics compared with persistently normotensive or hypertensive NIDDM patients. %WR in patients with new onset hypertension was significantly higher than in the control group (30.88%±16.87% vs 12.89%±11.94%, respectively, P<0.05). Moreover, in these patients %WR correlated with duration from the date of MIBG scintigraphy to the onset of hypertension (r=-0.512, P<0.05). Five NIDDM patients died during the follow-up period (four newly hypertensive patients and one normotensive patient). There were significant statistical differences

  2. Optical precursors from classical waves to single photons

    CERN Document Server

    Chen, JF; Loy, MMT; Du, Shengwang

    2013-01-01

    Ever since Einstein’s special relativity in 1905, the principle of invariant light speed in vacuum has been attracting attention from a wide range of disciplines. How to interpret the principle of light speed? Is light referred to continuous light, or light pulse with definite boundaries? Recent discovery of superluminal medium triggered vigorous discussion within the Physics community. Can communication via such “superluminal channel” break the speed limit and thus violate causality principle? Or, will a single photon, which is not governed by classical laws of Physics, tend to break the speed limit? To solve these problems, in this Brief we bring in optical precursor, the theoretical works for which started as early as 1914. This is a typical optical phenomenon combining wave propagation theory and light-wave interaction. Both theory and experimental works are covered in this Brief. The study of precursor verifies that the effective information carried by light pulses can never exceed the speed of lig...

  3. Application of single photon ECT for dynamic study

    International Nuclear Information System (INIS)

    Mukai, T.; Ishii, Y.; Tamaki, N.

    1982-01-01

    Feasibility of dynamic study in a form of ECT using a rotating gamma camera was evaluated. Since it takes longer one around time sampling, application for the dynamic study is limited under following conditions; 1) physiological gated process, 2) slow clearance process, 3) physiological steady state process. The gated study was applicated for heart pumping action synchronized with ECG. The ECG gated heart ECT either of blood pool or myocardium was useful to reveal a subtle wall motion abnormalities in a tomographic plane, even when a planar imaging failed to reveal it. As for slow dynamic process of tracer, an excretion process of hepatobiliary agent, was subjected to be analyzed in order to calculate clearance rate at each pixel. As for steady state process, an ECT of regional celebral blood flow (rCBF) was investigated during continuous infusion into intracarotid artery. All of these technique were proved to have a clinical feasibility and to potentiate usefulness of the single photon ECT (SPECT)

  4. Single photon emission computed tomography in AIDS dementia complex

    International Nuclear Information System (INIS)

    Pohl, P.; Vogl, G.; Fill, H.; Roessler, H.Z.; Zangerle, R.; Gerstenbrand, F.

    1988-01-01

    Single photon emission computed tomography (SPECT) studies were performed in AIDS dementia complex using IMP in 12 patients (and HM-PAO in four of these same patients). In all patients, SPECT revealed either multiple or focal uptake defects, the latter corresponding with focal signs or symptoms in all but one case. Computerized tomography showed a diffuse cerebral atrophy in eight of 12 patients, magnetic resonance imaging exhibited changes like atrophy and/or leukoencephalopathy in two of five cases. Our data indicate that both disturbance of cerebral amine metabolism and alteration of local perfusion share in the pathogenesis of AIDS dementia complex. SPECT is an important aid in the diagnosis of AIDS dementia complex and contributes to the understanding of the pathophysiological mechanisms of this disorder

  5. Superconducting nanowire single-photon detectors: physics and applications

    International Nuclear Information System (INIS)

    Natarajan, Chandra M; Tanner, Michael G; Hadfield, Robert H

    2012-01-01

    Single-photon detectors based on superconducting nanowires (SSPDs or SNSPDs) have rapidly emerged as a highly promising photon-counting technology for infrared wavelengths. These devices offer high efficiency, low dark counts and excellent timing resolution. In this review, we consider the basic SNSPD operating principle and models of device behaviour. We give an overview of the evolution of SNSPD device design and the improvements in performance which have been achieved. We also evaluate device limitations and noise mechanisms. We survey practical refrigeration technologies and optical coupling schemes for SNSPDs. Finally we summarize promising application areas, ranging from quantum cryptography to remote sensing. Our goal is to capture a detailed snapshot of an emerging superconducting detector technology on the threshold of maturity. (topical review)

  6. TCAD simulations for a novel single-photon avalanche diode

    Science.gov (United States)

    Jin, Xiangliang; Yang, Jia; Yang, Hongjiao; Tang, Lizhen; Liu, Weihui

    2015-03-01

    A single-photon avalanche diode (SPAD) device with P+-SEN junction, and a low concentration of N-type doping circular virtual guard-ring was presented in this paper. SEN layer of the proposed SPAD has high concentration of N-type doping, causing the SPAD low breakdown voltage (~14.26 V). What's more, an efficient and narrow (about 2μm) guard-ring of the proposed SPAD not only can withstand considerably higher electric fields for preventing edge breakdown, but also offers a little increment in fill factor compared with existing SPADs due to its small area. In addition, some Silvaco TCAD simulations have been done and verify characteristics and performance of the design in this work.

  7. Single-Photon Technologies Based on Quantum-Dots in Photonic Crystals

    DEFF Research Database (Denmark)

    Lehmann, Tau Bernstorff

    In this thesis, the application of semiconductor quantum-dots in photonic crystals is explored as aresource for single-photon technology.Two platforms based on photonic crystals, a cavity and a waveguide, are examined as platformssingle-photon sources. Both platforms demonstrate strong single-photon...... purity under quasi-resonantexcitation. Furthermore the waveguide based platform demonstrates indistinguishable single-photonsat timescales up to 13 ns.A setup for active demultiplexing of single-photons to a three-fold single-photon state is proposed.Using a fast electro-optical modulator, single-photons...... from a quantum-dot are routed on timescalesof the exciton lifetime. Using active demultiplexing a three-fold single-photon state is generated at anextracted rate of 2:03 ±0:49 Hz.An on-chip power divider integrated with a quantum-dot is investigated. Correlation measurementof the photon statistic...

  8. cGMP in Mouse Rods: the spatiotemporal dynamics underlying single photon responses

    Directory of Open Access Journals (Sweden)

    Owen P. Gross

    2015-03-01

    Full Text Available Vertebrate vision begins when retinal photoreceptors transduce photons into membrane hyperpolarization, which reduces glutamate release onto second-order neurons. In rod photoreceptors, transduction of single photons is achieved by a well-understood G-protein cascade that modulates cGMP levels, and in turn, cGMP-sensitive inward current. The spatial extent and depth of the decline in cGMP during the single photon response have been major issues in phototransduction research since the discovery that single photons elicit substantial and reproducible changes in membrane current. The spatial profile of cGMP decline during the single photon response affects signal gain, and thus may contribute to reduction of trial-to-trial fluctuations in the single photon response. Here we summarize the general principles of rod phototransduction, emphasizing recent advances in resolving the spatiotemporal dynamics of cGMP during the single photon response.

  9. Computational Modeling of Photonic Crystal Microcavity Single-Photon Emitters

    Science.gov (United States)

    Saulnier, Nicole A.

    Conventional cryptography is based on algorithms that are mathematically complex and difficult to solve, such as factoring large numbers. The advent of a quantum computer would render these schemes useless. As scientists work to develop a quantum computer, cryptographers are developing new schemes for unconditionally secure cryptography. Quantum key distribution has emerged as one of the potential replacements of classical cryptography. It relics on the fact that measurement of a quantum bit changes the state of the bit and undetected eavesdropping is impossible. Single polarized photons can be used as the quantum bits, such that a quantum system would in some ways mirror the classical communication scheme. The quantum key distribution system would include components that create, transmit and detect single polarized photons. The focus of this work is on the development of an efficient single-photon source. This source is comprised of a single quantum dot inside of a photonic crystal microcavity. To better understand the physics behind the device, a computational model is developed. The model uses Finite-Difference Time-Domain methods to analyze the electromagnetic field distribution in photonic crystal microcavities. It uses an 8-band k · p perturbation theory to compute the energy band structure of the epitaxially grown quantum dots. We discuss a method that combines the results of these two calculations for determining the spontaneous emission lifetime of a quantum dot in bulk material or in a microcavity. The computational models developed in this thesis are used to identify and characterize microcavities for potential use in a single-photon source. The computational tools developed are also used to investigate novel photonic crystal microcavities that incorporate 1D distributed Bragg reflectors for vertical confinement. It is found that the spontaneous emission enhancement in the quasi-3D cavities can be significantly greater than in traditional suspended slab

  10. Dynamically unpolarized single-photon source in diamond with intrinsic randomness

    OpenAIRE

    Abe, Naofumi; Mitsumori, Yasuyoshi; Sadgrove, Mark; Edamatsu, Keiichi

    2017-01-01

    Polarization is one of the fundamental properties of light, providing numerous applications in science and technology. While ?dynamically unpolarized? single-photon sources are demanded for various quantum applications, such sources have never been explored. Here we demonstrate dynamically unpolarized single-photon emission from a single [111]-oriented nitrogen- vacancy centre in diamond, in which the single-photon stream is unpolarized, exhibiting intrinsic randomness with vanishing polariza...

  11. Iodine-123-labeled radiotracers for cardiovascular and testicular imaging studies: labeling of phenyl fatty acids for myocardial studies, fibronectin for thrombus localization, and human chorionic gonadotropin for testicular studies

    International Nuclear Information System (INIS)

    Kulkarni, P.V.; Lewis, S.E.; McConnell, J.; Buja, L.M.; Wilson, J.E. III; Willerson, J.T.; Parkey, R.W.

    1985-01-01

    Development and evaluation of iodine-123-labeled compounds for potential applications in certain imaging studies are described. A new method utilizing an organothallium intermediate has been developed to radioiodinate phenyl fatty acids. The method is simple, and consistently high yields (80 to 90%) can be obtained on a routine basis. The biodistribution patterns of the product prepared by this method were found to be very similar to those produced by the direct electrophilic substitution method. Radioiodinated fibronectin (FN) localized in experimental thrombi and pulmonary emboli. In dogs the deep-vein thrombi could be visualized within 3 hr of postinjection of the tracer. Radioiodinated human chorionic gonadotropin (HCG) localized in rat testes which permitted the scintigraphic visualization of scrotal as well as abdominal testes in rats. The localization appears to be receptor mediated

  12. Corpuscular Model of Two-Beam Interference and Double-Slit Experiments with Single Photons

    NARCIS (Netherlands)

    Jin, Fengping; Yuan, Shengjun; De Raedt, Hans; Michielsen, Kristel; Miyashita, Seiji

    We introduce an event-based corpuscular simulation model that reproduces the wave mechanical results of single-photon double-slit and two-beam interference experiments and (of a one-to-one copy of an experimental realization) of a single-photon interference experiment with a Fresnel biprism. The

  13. Proceedings of clinical SPECT [single photon emission computed tomography] symposium

    International Nuclear Information System (INIS)

    1986-09-01

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base

  14. Proposal for automated transformations on single-photon multipath qudits

    Science.gov (United States)

    Baldijão, R. D.; Borges, G. F.; Marques, B.; Solís-Prosser, M. A.; Neves, L.; Pádua, S.

    2017-09-01

    We propose a method for implementing automated state transformations on single-photon multipath qudits encoded in a one-dimensional transverse spatial domain. It relies on transferring the encoding from this domain to the orthogonal one by applying a spatial phase modulation with diffraction gratings, merging all the initial propagation paths by using a stable interferometric network, and filtering out the unwanted diffraction orders. The automation feature is attained by utilizing a programmable phase-only spatial light modulator (SLM) where properly designed diffraction gratings displayed on its screen will implement the desired transformations, including, among others, projections, permutations, and random operations. We discuss the losses in the process which is, in general, inherently nonunitary. Some examples of transformations are presented and, considering a realistic scenario, we analyze how they will be affected by the pixelated structure of the SLM screen. The method proposed here enables one to implement much more general transformations on multipath qudits than is possible with a SLM alone operating in the diagonal basis of which-path states. Therefore, it will extend the range of applicability for this encoding in high-dimensional quantum information and computing protocols as well as fundamental studies in quantum theory.

  15. Single photon emission computed tomography in lumbar degenerative spondylolisthesis

    International Nuclear Information System (INIS)

    Ito, S.; Muro, T.; Eisenstein, S.

    1998-01-01

    Analysis of single photon emission computed tomographic images and plain X-ray films of the lumbar vertebrae was performed in 15 patients with lumbar spondylosis and 15 patients with lumbar degenerative spondylolisthesis. The facet joint and osteophyte images were observed in particular, and the slipping ratio of spondylolisthetic vertebrae was determined. The slipping ratio of degenerative spondylolisthesis ranged from 11.8 % to 22.3 %. Hot uptake of 99mTc-HMDP by both L4-5 facet joints was significantly greater in the patients with degenerative spondylolisthesis than in those with lumbar spondylosis. The hot uptake by the osteophytes in lumbar spondylosis was nearly uniform among the three inferior segments, L3-4, L4-5 and L5-S, but was localized to the spondylolisthetic vertebrae, L4-5, or L5-S, in the patients with spondylolisthesis. Half of the osteophytes with hot uptake were assigned to the 3rd degree of Nathan's grading. It was suggested that stress was localized to the slipping vertebrae and their facet joints in patients with lumbar degenerative spondylolisthesis. (author)

  16. Brain single photon emission computed tomography in neonates

    Energy Technology Data Exchange (ETDEWEB)

    Denays, R.; Van Pachterbeke, T.; Tondeur, M.; Spehl, M.; Toppet, V.; Ham, H.; Piepsz, A.; Rubinstein, M.; Nol, P.H.; Haumont, D. (Free Universities of Brussels (Belgium))

    1989-08-01

    This study was designed to rate the clinical value of ({sup 123}I)iodoamphetamine (IMP) or ({sup 99m}Tc) hexamethyl propylene amine oxyme (HM-PAO) brain single photon emission computed tomography (SPECT) in neonates, especially in those likely to develop cerebral palsy. The results showed that SPECT abnormalities were congruent in most cases with structural lesions demonstrated by ultrasonography. However, mild bilateral ventricular dilatation and bilateral subependymal porencephalic cysts diagnosed by ultrasound were not associated with an abnormal SPECT finding. In contrast, some cortical periventricular and sylvian lesions and all the parasagittal lesions well visualized in SPECT studies were not diagnosed by ultrasound scans. In neonates with subependymal and/or intraventricular hemorrhage the existence of a parenchymal abnormality was only diagnosed by SPECT. These results indicate that ({sup 123}I)IMP or ({sup 99m}Tc)HM-PAO brain SPECT shows a potential clinical value as the neurodevelopmental outcome is clearly related to the site, the extent, and the number of cerebral lesions. Long-term clinical follow-up is, however, mandatory in order to define which SPECT abnormality is associated with neurologic deficit.

  17. Anti-dynamic-crosstalk method for single photon LIDAR detection

    Science.gov (United States)

    Zhang, Fan; Liu, Qiang; Gong, Mali; Fu, Xing

    2017-11-01

    With increasing number of vehicles equipped with light detection and ranging (LIDAR), crosstalk is identified as a critical and urgent issue in the range detection for active collision avoidance. Chaotic pulse position modulation (CPPM) applied in the transmitting pulse train has been shown to prevent crosstalk as well as range ambiguity. However, static and unified strategy on discrimination threshold and the number of accumulated pulse is not valid against crosstalk with varying number of sources and varying intensity of each source. This paper presents an adaptive algorithm to distinguish the target echo from crosstalk with dynamic and unknown level of intensity in the context of intelligent vehicles. New strategy is given based on receiver operating characteristics (ROC) curves that consider the detection requirements of the probability of detection and false alarm for the scenario with varying crosstalk. In the adaptive algorithm, the detected results are compared by the new strategy with both the number of accumulated pulses and the threshold being raised step by step, so that the target echo can be exactly identified from crosstalk with the dynamic and unknown level of intensity. The validity of the algorithm has been verified through the experiments with a single photon detector and the time correlated single photo counting (TCSPC) technique, demonstrating a marked drop in required shots for identifying the target compared with static and unified strategy

  18. Single-Photon Emission Computed Tomography (SPECT) in childhood epilepsy

    International Nuclear Information System (INIS)

    Gulati, Sheffali; Kalra, Veena; Bal, C.S.

    2000-01-01

    The success of epilepsy surgery is determined strongly by the precise location of the epileptogenic focus. The information from clinical electrophysiological data needs to be strengthened by functional neuroimaging techniques. Single photon emission computed tomography (SPECT) available locally has proved useful as a localising investigation. It evaluates the regional cerebral blood flow and the comparison between ictal and interictal blood flow on SPECT has proved to be a sensitive nuclear marker for the site of seizure onset. Many studies justify the utility of SPECT in localising lesions to possess greater precision than interictal scalp EEG or anatomic neuroimaging. SPECT is of definitive value in temporal lobe epilepsy. Its role in extratemporal lobe epilepsy is less clearly defined. It is useful in various other generalized and partial seizure disorders including epileptic syndromes and helps in differentiating pseudoseizures from true seizures. The need for newer radiopharmaceutical agents with specific neurochemical properties and longer shelf life are under investigation. Subtraction ictal SPECT co-registered to MRI is a promising new modality. (author)

  19. A Search for Single Photon Events in Neutrino Interactions

    CERN Document Server

    Kullenberg, C.T.; Dimmery, D.; Tian, X.C.; Autiero, D.; Gninenko, S.; Rubbia, A.; Alekhin, S.; Astier, P.; Baldisseri, A.; Baldo-Ceolin, M.; Banner, M.; Bassompierre, G.; Benslama, K.; Besson, N.; Bird, I.; Blumenfeld, B.; Bobisut, F.; Bouchez, J.; Boyd, S.; Bueno, A.; Bunyatov, S.; Camilleri, L.; Cardini, A.; Cattaneo, P.W.; Cavasinni, V.; Cervera-Villanueva, A.; Challis, R.; Chukanov, A.; Collazuol, G.; Conforto, G.; Conta, C.; Contalbrigo, M.; Cousins, R.; Degaudenzi, H.; De Santo, A.; Del Prete, T.; Di Lella, L.; do Couto e Silva, E.; Dumarchez, J.; Ellis, M.; Feldman, G.J.; Ferrari, R.; Ferrère, D.; Flaminio, V.; Fraternali, M.; Gaillard, J.-M.; Gangler, E.; Geiser, A.; Geppert, D.; Gibin, D.; Godley, A.; Gomez-Cadenas, J.-J.; Gosset, J.; Gößling, C.; Gouanère, M.; Grant, A.; Graziani, G.; Guglielmi, A.; Hagner, C.; Hernando, J.; Hurst, P.; Hyett, N.; Iacopini, E.; Joseph, C.; Juget, F.; Kent, N.; Klimov, O.; Kokkonen, J.; Kovzelev, A.; Krasnoperov, A.; Kim, J.J.; Kirsanov, M.; Kulagin, S.; Lacaprara, S.; Lachaud, C.; Lakić, B.; Lanza, A.; La Rotonda, L.; Laveder, M.; Letessier-Selvon, A.; Levy, J.M.; Ling, J.; Linssen, L.; Ljubičic, A.; Long, J.; Lupi, A.; Lyubushkin, V.; Marchionni, A.; Martelli, F.; Méchain, X.; Mendiburu, J.-P.; Meyer, J.-P.; Mezzetto, M.; Moorhead, G.F.; Naumov, D.; Nédélec, P.; Nefedov, Yu.; Nguyen-Mau, C.; Orestano, D.; Pastore, F.; Peak, L.S.; Pennacchio, E.; Pessard, H.; Petti, R.; Placci, A.; Polesello, G.; Pollmann, D.; Polyarush, A.; Poulsen, C.; Popov, B.; Rebuffi, L.; Rico, J.; Riemann, P.; Roda, C.; Salvatore, F.; Samoylov, O.; Schahmaneche, K.; Schmidt, B.; Schmidt, T.; Sconza, A.; Scott, A.M.; Seaton, M.B.; Sevior, M.; Sillou, D.; Soler, F.J.P.; Sozzi, G.; Steele, D.; Stiegler, U.; Stipčević, M.; Stolarczyk, Th.; Tareb-Reyes, M.; Taylor, G.N.; Tereshchenko, V.; Toropin, A.; Touchard, A.-M.; Tovey, S.N.; Tran, M.-T.; Tsesmelis, E.; Ulrichs, J.; Vacavant, L.; Valdata-Nappi, M.; Valuev, V.; Vannucci, F.; Varvell, K.E.; Veltri, M.; Vercesi, V.; Vidal-Sitjes, G.; Vieira, J.-M.; Vinogradova, T.; Weber, F.V.; Weisse, T.; Wilson, F.F.; Winton, L.J.; Wu, Q.; Yabsley, B.D.; Zaccone, H.; Zuber, K.; Zuccon, P.

    2012-01-01

    We present a search for neutrino-induced events containing a single, exclusive photon using data from the NOMAD experiment at the CERN SPS where the average energy of the neutrino flux is $\\simeq 25$ GeV. The search is motivated by an excess of electron-like events in the 200--475 MeV energy region as reported by the MiniBOONE experiment. In NOMAD, photons are identified via their conversion to $e^+e^-$ in an active target embedded in a magnetic field. The background to the single photon signal is dominated by the asymmetric decay of neutral pions produced either in a coherent neutrino-nucleus interaction, or in a neutrino-nucleon neutral current deep inelastic scattering, or in an interaction occurring outside the fiducial volume. All three backgrounds are determined {\\it in situ} using control data samples prior to opening the `signal-box'. In the signal region, we observe {\\bf 155} events with a predicted background of {\\bf 129.2 $\\pm$ 8.5 $\\pm$ 3.3}. We interpret this as null evidence for excess of single...

  20. Proceedings of clinical SPECT (single photon emission computed tomography) symposium

    Energy Technology Data Exchange (ETDEWEB)

    1986-09-01

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base. (TEM)

  1. Low-noise low-jitter 32-pixels CMOS single-photon avalanche diodes array for single-photon counting from 300 nm to 900 nm

    Energy Technology Data Exchange (ETDEWEB)

    Scarcella, Carmelo; Tosi, Alberto, E-mail: alberto.tosi@polimi.it; Villa, Federica; Tisa, Simone; Zappa, Franco [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Piazza Leonardo da Vinci 32, I-20133 Milano (Italy)

    2013-12-15

    We developed a single-photon counting multichannel detection system, based on a monolithic linear array of 32 CMOS SPADs (Complementary Metal-Oxide-Semiconductor Single-Photon Avalanche Diodes). All channels achieve a timing resolution of 100 ps (full-width at half maximum) and a photon detection efficiency of 50% at 400 nm. Dark count rate is very low even at room temperature, being about 125 counts/s for 50 μm active area diameter SPADs. Detection performance and microelectronic compactness of this CMOS SPAD array make it the best candidate for ultra-compact time-resolved spectrometers with single-photon sensitivity from 300 nm to 900 nm.

  2. Cooling in the single-photon strong-coupling regime of cavity optomechanics

    Science.gov (United States)

    Nunnenkamp, A.; Børkje, K.; Girvin, S. M.

    2012-05-01

    In this Rapid Communication we discuss how red-sideband cooling is modified in the single-photon strong-coupling regime of cavity optomechanics where the radiation pressure of a single photon displaces the mechanical oscillator by more than its zero-point uncertainty. Using Fermi's golden rule we calculate the transition rates induced by the optical drive without linearizing the optomechanical interaction. In the resolved-sideband limit we find multiple-phonon cooling resonances for strong single-photon coupling that lead to nonthermal steady states including the possibility of phonon antibunching. Our study generalizes the standard linear cooling theory.

  3. Quantum dot resonant tunneling diode single photon detector with aluminum oxide aperture defined tunneling area

    DEFF Research Database (Denmark)

    Li, H.W.; Kardynal, Beata; Ellis, D.J.P.

    2008-01-01

    Quantum dot resonant tunneling diode single photon detector with independently defined absorption and sensing areas is demonstrated. The device, in which the tunneling is constricted to an aperture in an insulating layer in the emitter, shows electrical characteristics typical of high quality...... resonant tunneling diodes. A single photon detection efficiency of 2.1%+/- 0.1% at 685 nm was measured corresponding to an internal quantum efficiency of 14%. The devices are simple to fabricate, robust, and show promise for large absorption area single photon detectors based on quantum dot structures....

  4. NFAD Arrays for Single Photon Optical Communications at 1.5 um, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — For this program, we propose to develop large pixel-count single photon counting detector arrays suitable for deployment in spacecraft terminal receivers supporting...

  5. Single Photon Sensitive HgCdTe Avalanche Photodiode Detector (APD), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Leveraging Phase I SBIR successes, in Phase II, a single photon sensitive LIDAR receiver will be fabricated and delivered to NASA. In Phase I, high-gain,...

  6. Single-photon emission computed tomography and early death in acute ischemic stroke

    NARCIS (Netherlands)

    Limburg, M.; van Royen, E. A.; Hijdra, A.; de Bruïne, J. F.; Verbeeten, B. W.

    1990-01-01

    Single-photon emission computed tomography with thallium-201-labeled diethyldithiocarbamate was performed in 26 consecutive patients less than or equal to 24 hours after a supratentorial brain infarction. Computed tomography excluded other relevant pathology. Two observers assessed the initial

  7. Single-photon-level quantum image memory based on cold atomic ensembles.

    Science.gov (United States)

    Ding, Dong-Sheng; Zhou, Zhi-Yuan; Shi, Bao-Sen; Guo, Guang-Can

    2013-01-01

    A quantum memory is a key component for quantum networks, which will enable the distribution of quantum information. Its successful development requires storage of single-photon light. Encoding photons with spatial shape through higher-dimensional states significantly increases their information-carrying capability and network capacity. However, constructing such quantum memories is challenging. Here we report the first experimental realization of a true single-photon-carrying orbital angular momentum stored via electromagnetically induced transparency in a cold atomic ensemble. Our experiments show that the non-classical pair correlation between trigger photon and retrieved photon is retained, and the spatial structure of input and retrieved photons exhibits strong similarity. More importantly, we demonstrate that single-photon coherence is preserved during storage. The ability to store spatial structure at the single-photon level opens the possibility for high-dimensional quantum memories.

  8. Storing single photons emitted by a quantum memory on a highly excited Rydberg state.

    Science.gov (United States)

    Distante, Emanuele; Farrera, Pau; Padrón-Brito, Auxiliadora; Paredes-Barato, David; Heinze, Georg; de Riedmatten, Hugues

    2017-01-19

    Strong interaction between two single photons is a long standing and important goal in quantum photonics. This would enable a new regime of nonlinear optics and unlock several applications in quantum information science, including photonic quantum gates and deterministic Bell-state measurements. In the context of quantum networks, it would be important to achieve interactions between single photons from independent photon pairs storable in quantum memories. So far, most experiments showing nonlinearities at the single-photon level have used weak classical input light. Here we demonstrate the storage and retrieval of a paired single photon emitted by an ensemble quantum memory in a strongly nonlinear medium based on highly excited Rydberg atoms. We show that nonclassical correlations between the two photons persist after retrieval from the Rydberg ensemble. Our result is an important step towards deterministic photon-photon interactions, and may enable deterministic Bell-state measurements with multimode quantum memories.

  9. NFAD Arrays for Single Photon Optical Communications at 1.5 um, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — For this program, we propose to develop large pixel-count single photon counting detector arrays suitable for deployment in spacecraft terminal receivers supporting...

  10. Room-Temperature Single-Photon Source for Secure Quantum Communication

    Data.gov (United States)

    National Aeronautics and Space Administration — We are asking for four years of support for PhD student Justin Winkler's work on a research project entitled "Room temperature single photon source for secure...

  11. Direct Production of High $p_T$ Single Photons at the CERN Intersecting Storage Rings

    CERN Document Server

    Diakonou, M; Resvanis, L.K.; Filippas, T.A.; Fokitis, E.; Trakkas, C.; Cnops, A.M.; Cobb, J.H.; Fowler, E.C.; Hood, D.M.; Iwata, S.; Palmer, R.B.; Rahm, D.C.; Rehak, P.; Stumer, I.; Fabjan, C.W.; Fields, T.; Lissauer, D.; Mannelli, I.; Molzon, W.; Mouzourakis, P.; Nakamura, K.; Nappi, A.; Willis, W.J.

    1979-01-01

    Single photon production in pp collisions at 30 < √ s < 62 GeV has been measured with liquid-argon-lead calorimeters at the CERN ISR. This process remains approximately constant with increasing √ s . For fixed √ s , the single photon to π 0 ratio increases strongly with increase in p T . The γ π 0 ratio is about 0.2 for p T above 4.5 GeV/c.

  12. Tunable room-temperature single photon emission from atomic defects in hexagonal boron nitride

    Science.gov (United States)

    Grosso, Gabriele; Moon, Hyowon; Lienhard, Benjamin; Efetov, Dmitri; Furchi, Marco; Jarillo-Herrero, Pablo; Ali, Sajid; Ford, Michael; Aharonovich, Igor; Englund, Dirk

    Two-dimensional van der Waals materials have emerged as promising platforms for solid-state quantum information processing devices with unusual potential for heterogeneous assembly. Recently, bright and photostable single photon emitters were reported from atomic defects in layered hexagonal boron nitride (hBN), but controlling inhomogeneous spectral distribution and reducing multi-photon emission presented open challenges. We demonstrate that strain control allows spectral tunability of hBN single photon emitters, and material processing sharply improves the single-photon purity. Our sample fabrication process relies on ion irradiation and high temperature annealing to isolate individual defects for single photon emission. Spectroscopy on this emitter reports high single photon purity of g(2)(0) =0.07, and high count rates exceeding 107 counts/sec at saturation. Furthermore, these emitters are stable to material transfer to other substrates, including a bendable beam that allows us to controllably apply strain. Our experiments indicate a maximum tuning of 6 meV and emission energy dependencies ranging from -3 to 6 meV/%. High-purity and photostable single photon emission at room temperature, together with spectral tunability and transferability, opens the door to scalable integration of high-quality quantum emitters in photonic quantum technologies.

  13. Investigating and improving student understanding of quantum mechanics in the context of single photon interference

    Science.gov (United States)

    Marshman, Emily; Singh, Chandralekha

    2017-06-01

    Single photon experiments involving a Mach-Zehnder interferometer can illustrate the fundamental principles of quantum mechanics, e.g., the wave-particle duality of a single photon, single photon interference, and the probabilistic nature of quantum measurement involving single photons. These experiments explicitly make the connection between the abstract quantum theory and concrete laboratory settings and have the potential to help students develop a solid grasp of the foundational issues in quantum mechanics. Here we describe students' conceptual difficulties with these topics in the context of Mach-Zehnder interferometer experiments with single photons and how the difficulties found in written surveys and individual interviews were used as a guide in the development of a Quantum Interactive Learning Tutorial (QuILT). The QuILT uses an inquiry-based approach to learning and takes into account the conceptual difficulties found via research to help upper-level undergraduate and graduate students learn about foundational quantum mechanics concepts using the concrete quantum optics context. It strives to help students learn the basics of quantum mechanics in the context of single photon experiment, develop the ability to apply fundamental quantum principles to experimental situations in quantum optics, and explore the differences between classical and quantum ideas in a concrete context. We discuss the findings from in-class evaluations suggesting that the QuILT was effective in helping students learn these abstract concepts.

  14. Technology development for a single-photon source

    International Nuclear Information System (INIS)

    Enzmann, Roland

    2011-01-01

    the emission from 1.3 μm to 1.5 μm was obtained. To achieve high collection efficiency, the quantum dots should be embedded into photonic crystals. An ArCl 2 -etch-process was developed which enables the etch of small features in Al x Ga y In 1-x-y As material system to transfer the Si 3 N 4 -pattern into the semiconductor. Using this process the fabricated photonic crystals with L3-cavities had Q-factors around 2200. Any concept using a cavity needs a mechanism to control the frequency-detuning between the mode and the quantum dots, due to the inhomogeneous frequency broadening of the quantum dots. Thus an in-situ tuning mechanism is required for adjusting the emission wavelength of the quantum dot or cavity mode, respectively. This concept intents to use the quantum confined Stark effect (QCSE) to force the emission of a single photon out of a quantum dot into the photonic crystal mode. This is realized using a reversed biased Schottky contact to cause a red-shift of the emission of a single quantum dot. Electroluminescence measurements on the device show, that even with very low currents of 14.5 μA the saturation intensity of single quantum dots could be reached. (orig.)

  15. Correlation of regional wall motion and fatty acid metabolism in coronary artery disease, hypertension, and hypertrophic cardiomyopathy; Assessment by dual-isotope SPECT with thallium-201 and iodine-123 [beta]-methyl fatty acid analogue

    Energy Technology Data Exchange (ETDEWEB)

    Hase, Mamoru; Nakata, Tomoaki; Yonekura, Shuji (Sapporo Medical Coll. (Japan)) (and others)

    1993-05-01

    In order to investigate the correlation between cardiac fatty acid metabolism and regional wall motion, dual-isotope tomography using thallium-201 and iodine-123 labeled 15-(p-iodophenyl)-3-R, S-methylpentadecanoic acid (BMIPP), was performed in 15 patients with coronary artery disease (CAD), hypertension, or hypertrophic cardiomyopathy (HCM). The uptake of thallium and BMIPP was scored and compared with left ventricular regional wall motion assessed by 2-dimensional echocardiography and radionuclide ventriculography. The incidence of a complete agreement of thallium and BMIPP scores was significantly higher in hypertension (64%) and CAD (63%) groups compared to HCM patients (24%), while a lower BMIPP uptake compared to that of thallium (mismatching) was observed more frequently in HCM (65%) than in hypertension (31%) or CAD (33%). Only 3 infarct patients had regional wall motion abnormality which was detected in 20 (95%) of 21 segments with a low BMIPP uptake. Furthermore, compared to thallium perfusion, decreased BMIPP uptake much more corresponded to reduced wall motion in 8 of 11 segments with mismatching. Thus, metabolic abnormality assessed by BMIPP is well associated with asynergy in CAD patients, whereas the discrepancy of fatty acid metabolism and contraction is more dominant in HCM, suggesting that the combined assessment of thallium perfusion, BMIPP uptake, and regional wall motion might contribute to better understanding of the pathogenesis of various cardiac disorders. (author).

  16. Clinical usefulness of myocardial iodine-123-15-(p-iodophenyl)-3(R,S)-methyl-pentadecanoic acid distribution abnormality in patients with mitochondrial encephalomyopathy based on normal data file in bull's-eye polar map

    International Nuclear Information System (INIS)

    Takahashi, Nobukazu; Mitani, Isao; Sumita, Shinichi

    1998-01-01

    Visual interpretation of iodine-123-beta-15-(p-iodophenyl)-3(R,S)-methyl-pentadecanoic acid ( 123 I-BMIPP) myocardial images cannot easily detect mild reduction in tracer uptake. Objective assessment of myocardial 123 I-BMIPP maldistributions at rest was attempted using a bull's-eye map and its normal data file for detecting myocardial damage in patients with mitochondrial encephalomyopathy. Six patients, two with Kearns-Sayre syndrome and four with mitochondrial myopathy, encephalopathy, lactic acidosis, and strokelike episodes (MELAS), and 10 normal subjects were studied. Fractional myocardial uptake of 1 23 I-BMIPP was also measured by dynamic static imaging to assess the global myocardial free fatty acid. These data were compared with the cardiothoracic ratio measured by chest radiography and left ventricular ejection fraction assessed by echocardiography. Abnormal cardiothoracic ratio and lower ejection fraction were detected in only one patient with Kearns-Sayre syndrome. Abnormal fractional myocardial uptake was detected in two patients (1.61%, 1.91%), whereas abnormal regional 123 I-BMIPP uptake assessed by the bull's-eye map was detected in five patients (83%). All patients showed abnormal uptake in the anterior portion, and one showed progressive atrioventricular conduction abnormality and systolic dysfunction with extended 123 I-BMIPP abnormal uptake. The results suggest that assessment based on the normal data file in a bull's-eye polar map is clinically useful for detection of myocardial damage in patients with mitochondrial encephalomyopathy. (author)

  17. Pulsed single-photon spectrometer by frequency-to-time mapping using chirped fiber Bragg gratings.

    Science.gov (United States)

    Davis, Alex O C; Saulnier, Paul M; Karpiński, Michał; Smith, Brian J

    2017-05-29

    A fiber-integrated spectrometer for single-photon pulses outside the telecommunications wavelength range based upon frequency-to-time mapping, implemented by chromatic group delay dispersion (GDD), and precise temporally-resolved single-photon counting, is presented. A chirped fiber Bragg grating provides low-loss GDD, mapping the frequency distribution of an input pulse onto the temporal envelope of the output pulse. Time-resolved detection with fast single-photon-counting modules enables monitoring of a wavelength range from 825 nm to 835 nm with nearly uniform efficiency at 55 pm resolution (24 GHz at 830 nm). To demonstrate the versatility of this technique, spectral interference of heralded single photons and the joint spectral intensity distribution of a photon-pair source are measured. This approach to single-photon-level spectral measurements provides a route to realize applications of time-frequency quantum optics at visible and near-infrared wavelengths, where multiple spectral channels must be simultaneously monitored.

  18. Single-photon absorption by single photosynthetic light-harvesting complexes

    Science.gov (United States)

    Chan, Herman C. H.; Gamel, Omar E.; Fleming, Graham R.; Whaley, K. Birgitta

    2018-03-01

    We provide a unified theoretical approach to the quantum dynamics of absorption of single photons and subsequent excitonic energy transfer in photosynthetic light-harvesting complexes. Our analysis combines a continuous mode -photon quantum optical master equation for the chromophoric system with the hierarchy of equations of motion describing excitonic dynamics in presence of non-Markovian coupling to vibrations of the chromophores and surrounding protein. We apply the approach to simulation of absorption of single-photon coherent states by pigment–protein complexes containing between one and seven chromophores, and compare with results obtained by excitation using a thermal radiation field. We show that the values of excitation probability obtained under single-photon absorption conditions can be consistently related to bulk absorption cross-sections. Analysis of the timescale and efficiency of single-photon absorption by light-harvesting systems within this full quantum description of pigment–protein dynamics coupled to a quantum radiation field reveals a non-trivial dependence of the excitation probability and the excited state dynamics induced by exciton–phonon coupling during and subsequent to the pulse, on the bandwidth of the incident photon pulse. For bandwidths equal to the spectral bandwidth of Chlorophyll a, our results yield an estimation of an average time of ∼0.09 s for a single chlorophyll chromophore to absorb the energy equivalent of one (single-polarization) photon under irradiation by single-photon states at the intensity of sunlight.

  19. Multi-state discrimination below the quantum noise limit at the single-photon level

    Science.gov (United States)

    Ferdinand, A. R.; DiMario, M. T.; Becerra, F. E.

    2017-10-01

    Measurements approaching the ultimate quantum limits of sensitivity are central in quantum information processing, quantum metrology, and communication. Quantum measurements to discriminate multiple states at the single-photon level are essential for optimizing information transfer in low-power optical communications and quantum communications, and can enhance the capabilities of many quantum information protocols. Here, we theoretically investigate and experimentally demonstrate the discrimination of multiple coherent states of light with sensitivities surpassing the quantum noise limit (QNL) at the single-photon level under realistic conditions of loss and noise based on strategies implementing globally-optimized adaptive measurements with single photon counting and displacement operations. These discrimination strategies can provide realistic advantages to enhance information transfer at low powers, and are compatible with photon number resolving detection, which provides robustness at high powers, thus allowing for surpassing the QNL at arbitrary input power levels under realistic conditions.

  20. Single-photon compressive imaging with some performance benefits over raster scanning

    International Nuclear Information System (INIS)

    Yu, Wen-Kai; Liu, Xue-Feng; Yao, Xu-Ri; Wang, Chao; Zhai, Guang-Jie; Zhao, Qing

    2014-01-01

    A single-photon imaging system based on compressed sensing has been developed to image objects under ultra-low illumination. With this system, we have successfully realized imaging at the single-photon level with a single-pixel avalanche photodiode without point-by-point raster scanning. From analysis of the signal-to-noise ratio in the measurement we find that our system has much higher sensitivity than conventional ones based on point-by-point raster scanning, while the measurement time is also reduced. - Highlights: • We design a single photon imaging system with compressed sensing. • A single point avalanche photodiode is used without raster scanning. • The Poisson shot noise in the measurement is analyzed. • The sensitivity of our system is proved to be higher than that of raster scanning

  1. Fluctuation mechanisms in superconductors nanowire single-photon counters, enabled by effective top-down manufacturing

    CERN Document Server

    Bartolf, Holger

    2016-01-01

    Holger Bartolf discusses state-of-the-art detection concepts based on superconducting nanotechnology as well as sophisticated analytical formulæ that model dissipative fluctuation-phenomena in superconducting nanowire single-photon detectors. Such knowledge is desirable for the development of advanced devices which are designed to possess an intrinsic robustness against vortex-fluctuations and it provides the perspective for honorable fundamental science in condensed matter physics. Especially the nanowire detector allows for ultra-low noise detection of signals with single-photon sensitivity and GHz repetition rates. Such devices have a huge potential for future technological impact and might enable unique applications (e.g. high rate interplanetary deep-space data links from Mars to Earth). Contents Superconducting Single-Photon Detectors Nanotechnological Manufacturing; Scale: 10 Nanometer Berezinskii-Kosterlitz Thouless (BKT) Transition, Edge-Barrier, Phase Slips Target Groups Researchers and students of...

  2. Towards single photon generation using NV centers in diamond coupled to thin layer optical waveguides

    International Nuclear Information System (INIS)

    Toshiyuki Tashima

    2014-01-01

    Single photon emitters like the nitrogen-vacancy (NV) center in diamond are important for quantum communication such as quantum cryptography and quantum metrology. In this context, e.g. tapered optical nano-fibers are a promising approach as they allow efficient coupling of single photons into a single spatial mode. Yet, integration of such fibers in a compact integrated quantum circuit is demanding. Here we propose a NV defect center in diamond as a single photon emitter coupled to a thin layer photonic waveguide. The benefit is to allow smaller size devices while having a similar strong evanescent field like tapered nano-optical fibers. We present numerical simulations and fabrication steps of such structures. (author)

  3. A universal setup for active control of a single-photon detector

    International Nuclear Information System (INIS)

    Liu, Qin; Skaar, Johannes; Lamas-Linares, Antía; Kurtsiefer, Christian; Makarov, Vadim; Gerhardt, Ilja

    2014-01-01

    The influence of bright light on a single-photon detector has been described in a number of recent publications. The impact on quantum key distribution (QKD) is important, and several hacking experiments have been tailored to fully control single-photon detectors. Special attention has been given to avoid introducing further errors into a QKD system. We describe the design and technical details of an apparatus which allows to attack a quantum-cryptographic connection. This device is capable of controlling free-space and fiber-based systems and of minimizing unwanted clicks in the system. With different control diagrams, we are able to achieve a different level of control. The control was initially targeted to the systems using BB84 protocol, with polarization encoding and basis switching using beamsplitters, but could be extended to other types of systems. We further outline how to characterize the quality of active control of single-photon detectors

  4. Coherent single-photon absorption by single emitters coupled to one-dimensional nanophotonic waveguides

    DEFF Research Database (Denmark)

    Chen, Yuntian; Wubs, Martijn; Mørk, Jesper

    2011-01-01

    solutions for the dynamics of absorption, with maximum atomic excitation . We furthermore propose a terminated waveguide to aid the single-photon absorption. We found that for an emitter placed at an optimal distance from the termination, the maximum atomic excitation due to an incident single......We study the dynamics of single-photon absorption by a single emitter coupled to a one-dimensional waveguide that simultaneously provides channels for spontaneous emission (SE) decay and a channel for the input photon. We have developed a time-dependent theory that allows us to specify any input......-photon wavepacket can exceed 70%. This high value is a direct consequence of the high SE β-factor for emission into the waveguide. Finally, we have also explored whether waveguide dispersion could aid single-photon absorption by pulse shaping. For a Gaussian input wavepacket, we found that the absorption efficiency...

  5. Radioiodinated diacylglycerol analogue: a potential imaging agent for single-photon emission tomographic investigations of cerebral ischaemia

    Energy Technology Data Exchange (ETDEWEB)

    Ohmori, Y. [Department of Neurosurgery, Kyoto Prefectural University of Medicine, Kyoto (Japan); Imahori, Y. [Department of Neurosurgery, Kyoto Prefectural University of Medicine, Kyoto (Japan); Ueda, S. [Department of Neurosurgery, Kyoto Prefectural University of Medicine, Kyoto (Japan); Fujii, R. [Nishijin Hospital, Kyoto (Japan); Wakita, K. [Nishijin Hospital, Kyoto (Japan); Inoue, M. [Daiichi Radioisotope Laboratories, Chiba (Japan); Tazawa, S. [Daiichi Radioisotope Laboratories, Chiba (Japan)

    1996-03-01

    Phospholipid metabolism is closely related to membrane perturbation in cerebral ischaemia. We investigated in vivo topographical lipid metabolism using an iodine-123-labelled diacylglycerol analogue, (1-(15-(4-iodine-123-iodophenyl)-pentadecanoyl)-2-stearoyl-rac-glycerol) ({sup 123}I-labelled DAG), in a middle cerebral artery (MCA) occlusion model with the aim of positive imaging of ischaemic insult. Sprague-Dawley rats underwent coagulation of the MCA to induce permanent occlusion. MCA occlusion times prior to injection of {sup 123}I-labelled DAG ranged from 15 min to 14 days. Each rat was injected with 11-37 MBq of {sup 123}I-labelled DAG. After 30 min, in vivo autoradiographs were reconstructed. Scanning of the living rat brain in this MCA occlusion model was performed. Cerebral infarctions were recognized in the frontal cortex, the parietal cortex and the lateral portion of the caudate-putamen by 2, 3, 5-triphenyltetrazolium hydrochloride staining. In infarcted regions (region 1), {sup 123}I-labelled DAG incorporation showed a decrease up to 12 h; it then increased up to 6 days and decreased thereafter. In peri-infarcted regions (region 2), the incorporation showed almost no change up to 12 h, then increased up to 5-6 days and decreased thereafter. In other regions (region 3), the incorporation showed no change. Lipid analysis showed that {sup 123}I-labelled DAG was metabolized to 15-(4-iodine-123-iodophenyl)-pentadecanoic acid by DAG lipase and to {sup 123}I-labelled phosphatidylcholine. Scanning of the ischaemic region showed higher accumulation than on the non-lesioned side. We established a method to visualize ischaemic foci as positive images. The early changes in {sup 123}I-labelled DAG incorporation were related to DAG lipase, which degraded the accumulated intrinsic DAG, and increased {sup 123}I-labelled DAG incorporation in the chronic stage involves several aspects of neural destruction in the process of autolysis.

  6. Growth of optical-quality anthracene crystals doped with dibenzoterrylene for controlled single photon production

    Energy Technology Data Exchange (ETDEWEB)

    Major, Kyle D., E-mail: kyle.major11@imperial.ac.uk; Lien, Yu-Hung; Polisseni, Claudio; Grandi, Samuele; Kho, Kiang Wei; Clark, Alex S.; Hwang, J.; Hinds, E. A., E-mail: ed.hinds@imperial.ac.uk [Centre for Cold Matter, Department of Physics, Blackett Laboratory, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom)

    2015-08-15

    Dibenzoterrylene (DBT) molecules within a crystalline anthracene matrix show promise as quantum emitters for controlled, single photon production. We present the design and construction of a chamber in which we reproducibly grow doped anthracene crystals of optical quality that are several mm across and a few μm thick. We demonstrate control of the DBT concentration over the range 6–300 parts per trillion and show that these DBT molecules are stable single-photon emitters. We interpret our data with a simple model that provides some information on the vapour pressure of DBT.

  7. Continuous-Wave Single-Photon Transistor Based on a Superconducting Circuit

    DEFF Research Database (Denmark)

    Kyriienko, Oleksandr; Sørensen, Anders Søndberg

    2016-01-01

    We propose a microwave frequency single-photon transistor which can operate under continuous wave probing and represents an efficient single microwave photon detector. It can be realized using an impedance matched system of a three level artificial ladder-type atom coupled to two microwave cavities...... and the appearance of a photon flux leaving the second cavity through a separate input-output port. The proposal does not require time variation of the probe signals, thus corresponding to a passive version of a single-photon transistor. The resulting device is robust to qubit dephasing processes, possesses low dark...

  8. Bright quantum dot single photon source based on a low Q defect cavity

    DEFF Research Database (Denmark)

    Maier, Sebastian; Gold, Peter; Forchel, A.

    2014-01-01

    The quasi-planar single photon source presented in this paper shows an extraction efficiency of 42% without complex photonic resonator geometries or lithography steps as well as a high purity with a g2(0) value of 0.023.......The quasi-planar single photon source presented in this paper shows an extraction efficiency of 42% without complex photonic resonator geometries or lithography steps as well as a high purity with a g2(0) value of 0.023....

  9. Short-range energy budget simulator of single photon lidar demonstrator

    Science.gov (United States)

    Murtazin, Mark V.; Prochazka, Ivan; Blazej, Josef; Pershin, Sergey M.; Lednev, Vasily N.

    2017-05-01

    The compact single photon lidar demonstrator dedicated for asteroid rendezvous missions has been designed and realized in our laboratory two years ago. The instrument provides crucial data on altitude and terrain profile for altitudes exceeding 5 km with a precision of less than 10 cm fulfilling the Rayleigh criterion. One of the calibration procedure of demonstrator is the positioning of receiver and transmitter optics related to detector and laser and the aligning of transmitter and receiver optical common paths. To improve this particular indoor calibration procedure the new simulator of single photon energy budget during short range operation has been created. The comparison of simulated and experimental data will be presented and discussed.

  10. Single photon emission from charged excitons in CdTe/ZnTe quantum dots

    Science.gov (United States)

    Belyaev, K. G.; Rakhlin, M. V.; Sorokin, S. V.; Klimko, G. V.; Gronin, S. V.; Sedova, I. V.; Mukhin, I. S.; Ivanov, S. V.; Toropov, A. A.

    2017-11-01

    We report on micro-photoluminescence studies of individual self-organized CdTe/ZnTe quantum dots intended for single-photon-source applications in a visible spectral range. The quantum dots surface density below 1010 per cm2 was achieved by using a thermally activated regime of molecular beam epitaxy that allowed fabrication of etched mesa-structures containing only a few emitting quantum dots. The single photon emission with the autocorrelation function g(2)(0)<0.2 was detected and identified as recombination of charged excitons in the individual quantum dot.

  11. Wide-field single photon counting imaging with an ultrafast camera and an image intensifier

    Science.gov (United States)

    Zanda, Gianmarco; Sergent, Nicolas; Green, Mark; Levitt, James A.; Petrášek, Zdeněk; Suhling, Klaus

    2012-12-01

    We are reporting a method for wide-field photon counting imaging using a CMOS camera with a 40 kHz frame rate coupled with a three-stage image intensifier mounted on a standard fluorescence microscope. This system combines high frame rates with single photon sensitivity. The output of the phosphor screen, consisting of single-photon events, is collected by a CMOS camera allowing to create a wide-field image with parallel positional and timing information of each photon. Using a pulsed excitation source and a luminescent sample, the arrival time of hundreds of photons can be determined simultaneously in many pixels with microsecond resolution.

  12. Myocardial scintigraphy using iodine-123 15-(p-Iodophenyl)-3-R, S-methylpentadecanoic acid predicts the response to beta-blocker therapy in patients with dilated cardiomyopathy but does not reflect therapeutic effect

    Energy Technology Data Exchange (ETDEWEB)

    Yoshinaga, Keiichiro; Tahara, Minoru; Torii, Hiroyuki; Akimoto, Masaki [Kagoshima City Medical Association Hopital (Japan); Kihara, Koichi; Tei, Chuwa

    2000-05-01

    Myocardial fatty acid metabolism is disturbed in patients with idiopathic dilated cardiomyopathy. Myocardial scintigraphy using iodine-123 15-(p-iodophenyl)-3-R, S-methylpentadecanoic acid (BMIPP) was used to assess the response to {beta}-blocker therapy in 19 patients with dilated cardiomyopathy. BMIPP myocardial scintigraphy was performed before and 6 months after initiating {beta}-blocker therapy with metoprolol. Cardiac BMIPP uptake was assessed as the total defect score (TDS) and heart-to-mediastinum activity (H/M) ratio. Patients were classified retrospectively as responders with an improvement of at least one functional class (New York Heart Association) or an increase in ejection fraction of {>=}0.10 at 6 months, or as nonresponders meeting neither criterion. Responders had a significantly better pretreatment TDS (p<0.005) and H/M ratio (p<0.0001) than nonresponders. TDS exhibited no significant changes over 6 months in either group (responders: 13.2{+-}3.7 vs 12.5{+-}3.3; nonresponders: 20.8{+-}6.5 vs 20.5{+-}3.0). Responders showed no significant changes in H/M ratio (2.47{+-}0.28 vs 2.43{+-}0.42); paradoxically, nonresponders showed a significant increase from 1.82{+-}0.11 to 2.10{+-}0.19 (p<0.05), suggesting that {beta}-blocker therapy protected the myocardial fatty acid metabolism even in the absence of clinical improvement. BMIPP myocardial scintigraphy provides a prediction of response to {beta}-blocker treatment, but does not reflect the therapeutic effect in responders at 6 months. (author)

  13. Does Ca2+ reach millimolar concentrations after single photon absorption in Drosophila photoreceptor microvilli?

    NARCIS (Netherlands)

    Postma, Marten; Oberwinkler, J; Stavenga, DG

    1999-01-01

    The quantum bump, the elementary event of fly phototransduction induced by the absorption of a single photon, is a small, transient current due to the opening of cation-channels permeable to Ca2+. These channels are located in small, tube-like protrusions of the cell membrane, the microvilli. Using

  14. Resonant interaction of a single atom with single photons from a down-conversion source

    Science.gov (United States)

    Schuck, C.; Rohde, F.; Piro, N.; Almendros, M.; Huwer, J.; Mitchell, M. W.; Hennrich, M.; Haase, A.; Dubin, F.; Eschner, J.

    2010-01-01

    We observe the interaction of a single trapped calcium ion with single photons produced by a narrow-band, resonant down-conversion source [A. Haase , Opt. Lett. 34, 55 (2009)], employing a quantum jump scheme. Using the temperature dependence of the down-conversion spectrum and the tunability of the narrow source, absorption of the down-conversion photons is quantitatively characterized.

  15. A High-Efficiency Photonic Nanowire Single-Photon Source Featuring An Inverted Conical Taper

    DEFF Research Database (Denmark)

    Gregersen, Niels; Nielsen, Torben Roland; Mørk, Jesper

    2011-01-01

    A photonic nanowire single-photon source design incorporating an inverted conical tapering is proposed. The inverted taper allows for easy electrical contacting and a high photon extraction efficiency of 89 %. Unlike cavity-based approaches, the photonic nanowire features broadband spontaneous...... emission control and an improved tolerance towards fabrication imperfections....

  16. A high-efficiency electrically-pumped single-photon source based on a photonics nanowire

    DEFF Research Database (Denmark)

    Gregersen, Niels; Nielsen, Torben Roland; Mørk, Jesper

    An electrically-pumped single-photon source design with a predicted efficiency of 89% is proposed. The design is based on a quantum dot embedded in a photonic nanowire with tailored ends and optimized contact electrodes. Unlike cavity-based approaches, the photonic nanowire features broadband...

  17. New bi-dimensional SPAD arrays for time resolved single photon imaging

    Energy Technology Data Exchange (ETDEWEB)

    Grasso, R. [INFN-Laboratori Nazionali del Sud and Sez., INFN di Catania, Via S. Sofia 62, 95125 Catania (Italy); Dipartimento di Fisica ed Astronomia, Università di Catania, Via S. Sofia 64, 95123 Catania (Italy); Centro Siciliano di Fisica Nucleare e Struttura della Materia, Viale A. Doria 6, 95125 Catania (Italy); Tudisco, S., E-mail: tudisco@lns.infn.it [INFN-Laboratori Nazionali del Sud and Sez., INFN di Catania, Via S. Sofia 62, 95125 Catania (Italy); Centro Siciliano di Fisica Nucleare e Struttura della Materia, Viale A. Doria 6, 95125 Catania (Italy); Piemonte, C. [FBK-Fondazione Bruno Kessler, Via S. Croce 77, 38122 Trento (Italy); Lo Presti, D. [INFN-Laboratori Nazionali del Sud and Sez., INFN di Catania, Via S. Sofia 62, 95125 Catania (Italy); Dipartimento di Fisica ed Astronomia, Università di Catania, Via S. Sofia 64, 95123 Catania (Italy); Anzalone, A. [INFN-Laboratori Nazionali del Sud and Sez., INFN di Catania, Via S. Sofia 62, 95125 Catania (Italy); Musumeci, F.; Scordino, A. [INFN-Laboratori Nazionali del Sud and Sez., INFN di Catania, Via S. Sofia 62, 95125 Catania (Italy); Dipartimento di Fisica ed Astronomia, Università di Catania, Via S. Sofia 64, 95123 Catania (Italy); Serra, N.; Zorzi, N. [FBK-Fondazione Bruno Kessler, Via S. Croce 77, 38122 Trento (Italy)

    2013-08-01

    Some of the first results concerning the electrical and optical performances of new bi-dimensional single photon avalanche diodes arrays for imaging applications are briefly presented. The planned arrays were realized at the Fondazione Bruno Kessler—Trento and tested at LNS–INFN. The proposed new solution, utilizing a new architecture with integrated quenching resistors, allows to simplify the electronic readout.

  18. New bi-dimensional SPAD arrays for time resolved single photon imaging

    International Nuclear Information System (INIS)

    Grasso, R.; Tudisco, S.; Piemonte, C.; Lo Presti, D.; Anzalone, A.; Musumeci, F.; Scordino, A.; Serra, N.; Zorzi, N.

    2013-01-01

    Some of the first results concerning the electrical and optical performances of new bi-dimensional single photon avalanche diodes arrays for imaging applications are briefly presented. The planned arrays were realized at the Fondazione Bruno Kessler—Trento and tested at LNS–INFN. The proposed new solution, utilizing a new architecture with integrated quenching resistors, allows to simplify the electronic readout

  19. Monitoring CBF in clinical routine by dynamic single photon emission tomography (SPECT) of inhaled xenon-133

    DEFF Research Database (Denmark)

    Sugiyama, H; Christensen, J; Skyhøj Olsen, T

    1986-01-01

    A very simple and low-cost brain dedicated, rapidly rotating Single Photon Emission Tomograph SPECT is described. Its use in following patients with ischemic stroke is illustrated by two middle cerebral artery occlusion cases, one with persistent occlusion and low CBF in MCA territory, and one wi...

  20. Experimental single photon exchange along a space link of 7000 km

    DEFF Research Database (Denmark)

    Dequal, Daniele; Vallone, Giuseppe; Bacco, Davide

    2015-01-01

    at the Matera Laser Ranging Observatory. The single photon transmitter was realized by exploiting the corner cube retro-reflectors mounted on the LAGEOS-2 satellite. Long duration of data collection is possible with such altitude, up to 43 minutes in a single passage. The mean number of photons per pulse (µsat...

  1. On-Chip Waveguide Coupling of a Layered Semiconductor Single-Photon Source.

    Science.gov (United States)

    Tonndorf, Philipp; Del Pozo-Zamudio, Osvaldo; Gruhler, Nico; Kern, Johannes; Schmidt, Robert; Dmitriev, Alexander I; Bakhtinov, Anatoly P; Tartakovskii, Alexander I; Pernice, Wolfram; Michaelis de Vasconcellos, Steffen; Bratschitsch, Rudolf

    2017-09-13

    Fully integrated quantum technology based on photons is in the focus of current research, because of its immense potential concerning performance and scalability. Ideally, the single-photon sources, the processing units, and the photon detectors are all combined on a single chip. Impressive progress has been made for on-chip quantum circuits and on-chip single-photon detection. In contrast, nonclassical light is commonly coupled onto the photonic chip from the outside, because presently only few integrated single-photon sources exist. Here, we present waveguide-coupled single-photon emitters in the layered semiconductor gallium selenide as promising on-chip sources. GaSe crystals with a thickness below 100 nm are placed on Si 3 N 4 rib or slot waveguides, resulting in a modified mode structure efficient for light coupling. Using optical excitation from within the Si 3 N 4 waveguide, we find nonclassicality of generated photons routed on the photonic chip. Thus, our work provides an easy-to-implement and robust light source for integrated quantum technology.

  2. 3D near-infrared imaging based on a single-photon avalanche diode array sensor

    NARCIS (Netherlands)

    Mata Pavia, J.; Charbon, E.; Wolf, M.

    2011-01-01

    An imager for optical tomography was designed based on a detector with 128x128 single-photon pixels that included a bank of 32 time-to-digital converters. Due to the high spatial resolution and the possibility of performing time resolved measurements, a new contact-less setup has been conceived in

  3. Multiparty Quantum English Auction Scheme Using Single Photons as Message Carrier

    Science.gov (United States)

    Liu, Ge; Zhang, Jian-Zhong; Xie, Shu-Cui

    2018-03-01

    In this paper, a secure and economic multiparty english auction protocol using the single photons as message carrier of bids is proposed. In order to achieve unconditional security, fairness, undeniability and so on, we adopt the decoy photon checking technique and quantum encryption algorithm. Analysis result shows that our protocol satisfies all the characteristics of traditional english auction, meanwhile, it can resist malicious attacks.

  4. Near-unity efficiency, single-photon sources based on tapered photonic nanowires

    DEFF Research Database (Denmark)

    Bleuse, Joël; Munsch, Mathieu; Claudon, Julien

    2012-01-01

    Single-photon emission from excitons in InAs Quantum Dots (QD) embedded in GaAs Tapered Photonic Wires (TPW) already demonstrated a 0.72 collection efficiency, with TPWs were the apex is the sharp end of the cone. Going to alternate designs, still based on the idea of the adiabatic deconfinement...

  5. A new single-photon avalanche diode in 90nm standard CMOS technology

    NARCIS (Netherlands)

    Karami, M.A.; Gersbach, M.; Charbon, E.

    2010-01-01

    A single-photon avalanche diode (SPAD) fabricated in a 90nm standard CMOS process is reported. The detector comprises an octagonal multiplication region and a guard ring to prevent premature edge breakdown using exclusively standard layers. The proposed structure is the result of a systematic study

  6. Characterization of Single-Photon Avalanche Diodes in Standard 140-nm SOI CMOS Technology

    NARCIS (Netherlands)

    Lee, M.J.; Sun, P.; Charbon, E.

    2015-01-01

    We report on the characterization of single-photon avalanche diodes (SPADs) fabricated in standard 140-nm silicon on insulator (SOI) complementary metal-oxide-semiconductor (CMOS) technology. As a methodology for SPAD optimization, a test structure array, called SPAD farm, was realized with several

  7. Multiparty Quantum English Auction Scheme Using Single Photons as Message Carrier

    Science.gov (United States)

    Liu, Ge; Zhang, Jian-Zhong; Xie, Shu-Cui

    2017-11-01

    In this paper, a secure and economic multiparty english auction protocol using the single photons as message carrier of bids is proposed. In order to achieve unconditional security, fairness, undeniability and so on, we adopt the decoy photon checking technique and quantum encryption algorithm. Analysis result shows that our protocol satisfies all the characteristics of traditional english auction, meanwhile, it can resist malicious attacks.

  8. Bright single photon source based on self-aligned quantum dot–cavity systems

    DEFF Research Database (Denmark)

    Maier, Sebastian; Gold, Peter; Forchel, Alfred

    2014-01-01

    We report on a quasi-planar quantum-dot-based single-photon source that shows an unprecedented high extraction efficiency of 42% without complex photonic resonator geometries or post-growth nanofabrication. This very high efficiency originates from the coupling of the photons emitted by a quantum...

  9. Fundamental limitations in spontaneous emission rate of single-photon sources

    DEFF Research Database (Denmark)

    Bozhevolnyi, Sergey I.; Khurgin, Jacob B.

    2016-01-01

    The rate of single-photon generation by quantum emitters (QEs) can be enhanced by placing a QE inside a resonant structure. This structure can represent an all-dielectric micro-resonator or waveguide and thus be characterized by ultra-low loss and dimensions on the order of wavelength. Or it can ...

  10. Controlling light emission from single-photon sources using photonic nanowires

    DEFF Research Database (Denmark)

    Gregersen, Niels; Chen, Yuntian; Mørk, Jesper

    2012-01-01

    The photonic nanowire has recently emerged as an promising alternative to microcavity-based single-photon source designs. In this simple structure, a geometrical effect ensures a strong coupling between an embedded emitter and the optical mode of interest and a combination of tapers and mirrors a...... designs allowing for electrical contacting, polarization control, improved efficiency and simplified fabrication....

  11. Flexible ultrathin-body single-photon avalanche diode sensors and CMOS integration

    NARCIS (Netherlands)

    Sun, P.; Ishihara, R.; Charbon, E.

    2016-01-01

    We proposed the world’s first flexible ultrathin-body single-photon avalanche diode (SPAD) as photon counting device providing a suitable solution to advanced implantable bio-compatible chronic medical monitoring, diagnostics and other applications. In this paper, we investigate the Geiger-mode

  12. Evaluation of a 99Tcm bound brain scanning agent for single photon emission computed tomography

    DEFF Research Database (Denmark)

    Andersen, A R; Hasselbalch, S G; Paulson, O B

    1986-01-01

    D,L HM-PAO-99Tcm (PAO) is a lipophilic tracer complex which is avidly taken up by the brain. We have compared the regional distribution of PAO with regional cerebral blood flow (CBF). CBF was measured by single photon emission computed tomography (SPECT) by Tomomatic 64 after 133Xe inhalation in 41...

  13. Large scale fabrication of nitrogen vacancy-embedded diamond nanostructures for single-photon source applications

    Science.gov (United States)

    Jiang, Qianqing; Li, Wuxia; Tang, Chengchun; Chang, Yanchun; Hao, Tingting; Pan, Xinyu; Ye, Haitao; Li, Junjie; Gu, Changzhi

    2016-11-01

    Some color centers in diamond can serve as quantum bits which can be manipulated with microwave pulses and read out with laser, even at room temperature. However, the photon collection efficiency of bulk diamond is greatly reduced by refraction at the diamond/air interface. To address this issue, we fabricated arrays of diamond nanostructures, differing in both diameter and top end shape, with HSQ and Cr as the etching mask materials, aiming toward large scale fabrication of single-photon sources with enhanced collection efficiency made of nitrogen vacancy (NV) embedded diamond. With a mixture of O2 and CHF3 gas plasma, diamond pillars with diameters down to 45 nm were obtained. The top end shape evolution has been represented with a simple model. The tests of size dependent single-photon properties confirmed an improved single-photon collection efficiency enhancement, larger than tenfold, and a mild decrease of decoherence time with decreasing pillar diameter was observed as expected. These results provide useful information for future applications of nanostructured diamond as a single-photon source. Project supported by the National Key Research and Development Plan of China (Grant No. 2016YFA0200402), the National Natural Science Foundation of China (Grants Nos. 11574369, 11574368, 91323304, 11174362, and 51272278), and the FP7 Marie Curie Action (project No. 295208) sponsored by the European Commission.

  14. Nonlocality of a single photon: Paths to an Einstein-Podolsky-Rosen-steering experiment

    International Nuclear Information System (INIS)

    Jones, S. J.; Wiseman, H. M.

    2011-01-01

    A single-photon incident on a beam splitter produces an entangled field state, and in principle could be used to violate a Bell inequality, but such an experiment (without postselection) is beyond the reach of current experiments. Here we consider the somewhat simpler task of demonstrating Einstein-Podolsky-Rosen (EPR) steering with a single photon (also without postselection). We demonstrate that Alice's choice of measurement on her portion of the entangled state can affect Bob's portion of the entangled state in his laboratory, in a sense rigorously defined by us and Doherty [Phys. Rev. Lett. 98, 140402 (2007)]. Previous work by Lvovsky and coworkers [Phys. Rev. Lett. 92, 047903 (2004)] has addressed this phenomenon (which they called remote preparation) experimentally using homodyne measurements on a single photon. Here we show that, unfortunately, their experimental parameters do not meet the bounds necessary for a rigorous demonstration of EPR steering with a single photon. However, we also show that modest improvements in the experimental parameters, and the addition of photon counting to the arsenal of Alice's measurements, would be sufficient to allow such a demonstration.

  15. Single-photon switch: Controllable scattering of photons inside a one-dimensional resonator waveguide

    Science.gov (United States)

    Zhou, L.; Gong, Z. R.; Liu, Y. X.; Sun, C. P.; Nori, F.

    2010-03-01

    We analyze the coherent transport of a single photon, which propagates in a one-dimensional coupled-resonator waveguide and is scattered by a controllable two-level system located inside one of the resonators of this waveguide. Our approach, which uses discrete coordinates, unifies low and high energy effective theories for single-photon scattering. We show that the controllable two-level system can behave as a quantum switch for the coherent transport of a single photon. This study may inspire new electro-optical single-photon quantum devices. We also suggest an experimental setup based on superconducting transmission line resonators and qubits. References: L. Zhou, Z.R. Gong, Y.X. Liu, C.P. Sun, F. Nori, Controllable scattering of photons inside a one-dimensional resonator waveguide, Phys. Rev. Lett. 101, 100501 (2008). L. Zhou, H. Dong, Y.X. Liu, C.P. Sun, F. Nori, Quantum super-cavity with atomic mirrors, Phys. Rev. A 78, 063827 (2008).

  16. Single photon emission computed tomography in motor neuron disease with dementia

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, H.; Udaka, F.; Kishi, Y.; Seriu, N.; Ohtani, S.; Abe, K.; Mezaki, T.; Kameyama, M.; Honda, M.; Tomonobu, M.

    1988-12-01

    Single photon emission computed tomography with (123 I) isopropylamphetamine was carried out on a patient with motor neutron disease with dementia. (123 I) uptake was decreased in the frontal lobes. This would reflect the histopathological findings such as neuronal loss and gliosis in the frontal lobes.

  17. Single photon emission computed tomography in motor neuron disease with dementia.

    Science.gov (United States)

    Sawada, H; Udaka, F; Kishi, Y; Seriu, N; Mezaki, T; Kameyama, M; Honda, M; Tomonobu, M

    1988-01-01

    Single photon emission computed tomography with [123 I] isopropylamphetamine was carried out on a patient with motor neuron disease with dementia. [123 I] uptake was decreased in the frontal lobes. This would reflect the histopathological findings such as neuronal loss and gliosis in the frontal lobes.

  18. Measurement and modeling of microlenses fabricated on single-photon avalanche diode arrays for fill factor recovery

    NARCIS (Netherlands)

    Mata Pavia, J.; Wolf, M.; Charbon, E.

    2014-01-01

    Single-photon avalanche diode (SPAD) imagers typically have a relatively low fil factor, i.e. a low proportion of the pixel’s surface is light sensitive, due to in-pixel circuitry. We present a microlens array fabricated on a 128x128 single-photon avalanche diode (SPAD) imager to enhance its

  19. Radio frequency phototube and optical clock: High resolution, high rate and highly stable single photon timing technique

    Energy Technology Data Exchange (ETDEWEB)

    Margaryan, Amur

    2011-10-01

    A new timing technique for single photons based on the radio frequency phototube and optical clock or femtosecond optical frequency comb generator is proposed. The technique has a 20 ps resolution for single photons, is capable of operating with MHz frequencies and achieving 10 fs instability level.

  20. Increasing the collection efficiency of time-correlated single-photon counting with single-photon avalanche diodes using immersion lenses.

    Science.gov (United States)

    Pichette, Charles; Giudice, Andrea; Thibault, Simon; Bérubé-Lauzière, Yves

    2016-11-20

    Single-photon avalanche diodes (SPADs) achieving high timing resolution (≈20-50  ps) developed for time-correlated single-photon counting (TCSPC) generally have very small photosensitive areas (25-100 μm in diameter). This limits the achievable photon counting rate and signal-to-noise ratio and may lead to long counting times. This is detrimental in applications requiring several measurements, such as fluorescence lifetime imaging (FLIM) microscopy, which requires scanning, and time-domain diffuse optical tomography (TD-DOT). We show in this work that the use of an immersion lens directly affixed onto the photosensitive area of the SPAD helps alleviate this problem by allowing more light to be concentrated onto the detector. Following careful optical design and simulations, our experimental results show that it is actually possible to achieve the predicted theoretical increase in the photon counting rate (we achieve a factor of ≈4 here). This work is of high relevance in high timing resolution TCSPC with small photosensitive area detectors and should find widespread interest in FLIM and TD-DOT with SPADs.

  1. Simple and efficient absorption filter for single photons from a cold atom quantum memory.

    Science.gov (United States)

    Stack, Daniel T; Lee, Patricia J; Quraishi, Qudsia

    2015-03-09

    The ability to filter unwanted light signals is critical to the operation of quantum memories based on neutral atom ensembles. Here we demonstrate an efficient frequency filter which uses a vapor cell filled with (85)Rb and a buffer gas to attenuate both residual laser light and noise photons by nearly two orders of magnitude with little loss to the single photons associated with our cold (87)Rb quantum memory. This simple, passive filter provides an additional 18 dB attenuation of our pump laser and erroneous spontaneous emissions for every 1 dB loss of the single photon signal. We show that the addition of a frequency filter increases the non-classical correlations and the retrieval efficiency of our quantum memory by ≈ 35%.

  2. Development of a high-speed single-photon pixellated detector for visible wavelengths

    CERN Document Server

    Mac Raighne, Aaron; Mathot, Serge; McPhate, Jason; Vallerga, John; Jarron, Pierre; Brownlee, Colin; O’Shea, Val

    2009-01-01

    We present the development of a high-speed, single-photon counting, Hybrid Photo Detector (HPD). The HPD consists of a vacuum tube, containing the detector assembly, sealed with a transparent optical input window. Photons incident on the photocathode eject a photoelectron into a large electric field, which accelerates the incident electron onto a silicon detector. The silicon detector is bump bonded to a Medipix readout chip. This set-up allows for the detection and readout of low incident photon intensities at rates that are otherwise unattainable with current camera technology. Reported is the fabrication of the camera that brings together a range of sophisticated design and fabrication techniques and the expected theoretical imaging performance. Applications to cellular and molecular microscopy are also described in which single-photon-counting abilities at high frame rates are crucial

  3. Fabrication of superconducting nanowire single-photon detectors by nonlinear femtosecond optical lithography

    Science.gov (United States)

    Minaev, N. V.; Tarkhov, M. A.; Dudova, D. S.; Timashev, P. S.; Chichkov, B. N.; Bagratashvili, V. N.

    2018-02-01

    This paper describes a new approach to the fabrication of superconducting nanowire single-photon detectors from ultrathin NbN films on SiO2 substrates. The technology is based on nonlinear femtosecond optical lithography and includes direct formation of the sensitive element of the detector (the meander) through femtosecond laser exposure of the polymethyl methacrylate resist at a wavelength of 525 nm and subsequent removal of NbN using plasma-chemical etching. The nonlinear femtosecond optical lithography method allows the formation of planar structures with a spatial resolution of ~50 nm. These structures were used to fabricate single-photon superconducting detectors with quantum efficiency no worse than 8% at a wavelength of 1310 nm and dark count rate of 10 s‑1 at liquid helium temperature.

  4. Quantum key distribution with a single photon from a squeezed coherent state

    International Nuclear Information System (INIS)

    Matsuoka, Masahiro; Hirano, Takuya

    2003-01-01

    Squeezing of the coherent state by optical parametric amplifier is shown to efficiently produce single-photon states with reduced multiphoton probabilities compared with the weak coherent light. It can be a better source for a longer-distance quantum key distribution and also for other quantum optical experiments. The necessary condition for a secure quantum key distribution given by Brassard et al. is analyzed as functions of the coherent-state amplitude and squeeze parameter. Similarly, the rate of the gained secure bits G after error correction and privacy amplification given by Luetkenhaus is calculated. Compared with the weak coherent light, it is found that G is about ten times larger and its high level continues on about two times longer distance. By improvement of the detector efficiency it is shown that the distance extends further. Measurement of the intensity correlation function and the relation to photon antibunching are discussed for the experimental verification of the single-photon generation

  5. Invariant operator theory for the single-photon energy in time-varying media

    International Nuclear Information System (INIS)

    Jeong-Ryeol, Choi

    2010-01-01

    After the birth of quantum mechanics, the notion in physics that the frequency of light is the only factor that determines the energy of a single photon has played a fundamental role. However, under the assumption that the theory of Lewis–Riesenfeld invariants is applicable in quantum optics, it is shown in the present work that this widely accepted notion is valid only for light described by a time-independent Hamiltonian, i.e., for light in media satisfying the conditions, ε(i) = ε(0), μ(t) = μ(0), and σ(t) = 0 simultaneously. The use of the Lewis–Riesenfeld invariant operator method in quantum optics leads to a marvelous result: the energy of a single photon propagating through time-varying linear media exhibits nontrivial time dependence without a change of frequency. (general)

  6. Efficient fiber-coupled single-photon sources based on quantum dots

    DEFF Research Database (Denmark)

    Daveau, Raphaël Sura

    This thesis presents the study of solid-state quantum emitters in two dierent forms. The rst part of the thesis deals with quantum dot based single-photon sources with an emphasis on ecient photon extraction into an optical ber. The second part of the thesis covers a theoretical study of optical...... refrigeration with coupled quantum wells. Many photonic quantum information processing applications would benet from a highbrightness, ber-coupled source of triggered single photons. This thesis presents a study of such sources based on quantum dots coupled to unidirectional photonic-crystal waveguide devices...... the characterization of single quantum dots. The second method, evanescent coupling from a tapered waveguide to a microber, demonstrates a chip-to-ber coupling eciency exceeding 80 % in passive re- ection measurements. The characterization of quantum dots from this device establishes a ber-coupled source eciency of 15...

  7. Ultrathin NbN film superconducting single-photon detector array

    International Nuclear Information System (INIS)

    Smirnov, K; Korneev, A; Minaeva, O; Divochiy, A; Tarkhov, M; Ryabchun, S; Seleznev, V; Kaurova, N; Voronov, B; Gol'tsman, G; Polonsky, S

    2007-01-01

    We report on the fabrication process of the 2 x 2 superconducting single-photon detector (SSPD) array. The SSPD array is made from ultrathin NbN film and is operated at liquid helium temperatures. Each detector is a nanowire-based structure patterned by electron beam lithography process. The advances in fabrication technology allowed us to produce highly uniform strips and preserve superconducting properties of the unpatterned film. SSPD exhibit up to 30% quantum efficiency in near infrared and up to 1% at 5-μm wavelength. Due to 120 MHz counting rate and 18 ps jitter, the time-domain multiplexing read-out is proposed for large scale SSPD arrays. Single-pixel SSPD has already found a practical application in non-invasive testing of semiconductor very-large scale integrated circuits. The SSPD significantly outperformed traditional single-photon counting avalanche diodes

  8. Two-Color Single-Photon Photoinitiation and Photoinhibition for Subdiffraction Photolithography

    Science.gov (United States)

    Scott, Timothy F.; Kowalski, Benjamin A.; Sullivan, Amy C.; Bowman, Christopher N.; McLeod, Robert R.

    2009-05-01

    Controlling and reducing the developed region initiated by photoexposure is one of the fundamental goals of optical lithography. Here, we demonstrate a two-color irradiation scheme whereby initiating species are generated by single-photon absorption at one wavelength while inhibiting species are generated by single-photon absorption at a second, independent wavelength. Co-irradiation at the second wavelength thus reduces the polymerization rate, delaying gelation of the material and facilitating enhanced spatial control over the polymerization. Appropriate overlapping of the two beams produces structures with both feature sizes and monomer conversions otherwise unobtainable with use of single- or two-photon absorption photopolymerization. Additionally, the generated inhibiting species rapidly recombine when irradiation with the second wavelength ceases, allowing for fast sequential exposures not limited by memory effects in the material and thus enabling fabrication of complex two- or three-dimensional structures.

  9. A Single-Photon Avalanche Diode Array for Fluorescence Lifetime Imaging Microscopy

    Science.gov (United States)

    Schwartz, David Eric; Charbon, Edoardo; Shepard, Kenneth L.

    2013-01-01

    We describe the design, characterization, and demonstration of a fully integrated single-photon avalanche diode (SPAD) imager for use in time-resolved fluorescence imaging. The imager consists of a 64-by-64 array of active SPAD pixels and an on-chip time-to-digital converter (TDC) based on a delay-locked loop (DLL) and calibrated interpolators. The imager can perform both standard time-correlated single-photon counting (TCSPC) and an alternative gated-window detection useful for avoiding pulse pile-up when measuring bright signal levels. To illustrate the use of the imager, we present measurements of the decay lifetimes of fluorescent dyes of several types with a timing resolution of 350 ps. PMID:23976789

  10. Highly efficient photonic nanowire single-photon sources for quantum information applications

    DEFF Research Database (Denmark)

    Gregersen, Niels; Claudon, J.; Munsch, M.

    2013-01-01

    must feature near-unity efficiency, where the efficiency is defined as the number of detected photons per trigger, the probability g(2)(τ=0) of multi-photon emission events should be 0 and the emitted photons are required to be indistinguishable. An optically or electrically triggered quantum light......Within the emerging field of optical quantum information processing, the current challenge is to construct the basic building blocks for the quantum computing and communication systems. A key component is the singlephoton source (SPS) capable of emitting single photons on demand. Ideally, the SPS...... emitter, e.g. a nitrogen-vacancy center or a semiconductor quantum dot (QD), embedded in a solid-state semiconductor host material appears as an attractive platform for generating such single photons. However, for a QD in bulk material, the large index contrast at the semiconductor-air interface leads...

  11. Memory effect in silicon time-gated single-photon avalanche diodes

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Mora, A.; Contini, D., E-mail: davide.contini@polimi.it; Di Sieno, L. [Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milano (Italy); Tosi, A.; Boso, G.; Villa, F. [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milano (Italy); Pifferi, A. [Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milano (Italy); CNR, Istituto di Fotonica e Nanotecnologie, Piazza Leonardo da Vinci 32, I-20133 Milano (Italy)

    2015-03-21

    We present a comprehensive characterization of the memory effect arising in thin-junction silicon Single-Photon Avalanche Diodes (SPADs) when exposed to strong illumination. This partially unknown afterpulsing-like noise represents the main limiting factor when time-gated acquisitions are exploited to increase the measurement dynamic range of very fast (picosecond scale) and faint (single-photon) optical signals following a strong stray one. We report the dependences of this unwelcome signal-related noise on photon wavelength, detector temperature, and biasing conditions. Our results suggest that this so-called “memory effect” is generated in the deep regions of the detector, well below the depleted region, and its contribution on detector response is visible only when time-gated SPADs are exploited to reject a strong burst of photons.

  12. Recyclable amplification for single-photon entanglement from photon loss and decoherence

    Science.gov (United States)

    Zhou, Lan; Chen, Ling-Quan; Zhong, Wei; Sheng, Yu-Bo

    2018-01-01

    We put forward a highly efficient recyclable single-photon assisted amplification protocol, which can protect single-photon entanglement (SPE) from photon loss and decoherence. Making use of quantum nondemolition detection gates constructed with the help of cross-Kerr nonlinearity, our protocol has some attractive advantages. First, the parties can recover less-entangled SPE to be maximally entangled SPE, and reduce photon loss simultaneously. Second, if the protocol fails, the parties can repeat the protocol to reuse some discarded items, which can increase the success probability. Third, when the protocol is successful, they can similarly repeat the protocol to further increase the fidelity of the SPE. Thereby, our protocol provides a possible way to obtain high entanglement, high fidelity and high success probability simultaneously. In particular, our protocol shows higher success probability in the practical high photon loss channel. Based on the above features, our amplification protocol has potential for future application in long-distance quantum communication.

  13. On-chip III-V monolithic integration of heralded single photon sources and beamsplitters

    Science.gov (United States)

    Belhassen, J.; Baboux, F.; Yao, Q.; Amanti, M.; Favero, I.; Lemaître, A.; Kolthammer, W. S.; Walmsley, I. A.; Ducci, S.

    2018-02-01

    We demonstrate a monolithic III-V photonic circuit combining a heralded single photon source with a beamsplitter, at room temperature and telecom wavelength. Pulsed parametric down-conversion in an AlGaAs waveguide generates counterpropagating photons, one of which is used to herald the injection of its twin into the beamsplitter. We use this configuration to implement an integrated Hanbury-Brown and Twiss experiment, yielding a heralded second-order correlation gher(2 )(0 )=0.10 ±0.02 that confirms single-photon operation. The demonstrated generation and manipulation of quantum states on a single III-V semiconductor chip opens promising avenues towards real-world applications in quantum information.

  14. Tunable single-photon multi-channel quantum router based on an optomechanical system

    Science.gov (United States)

    Ma, Peng-Cheng; Yan, Lei-Lei; Zhang, Jian; Chen, Gui-Bin; Li, Xiao-Wei; Zhan, You-Bang

    2018-01-01

    Routing of photons plays a key role in optical communication networks and quantum networks. Although the quantum routing of signals has been investigated for various systems, both in theory and experiment, the general form of a quantum router with multi-output terminals still needs to be explored. Here, we propose an experimentally accessible tunable single-photon multi-channel routing scheme using an optomechanics cavity which is Coulomb coupled to a nanomechanical resonator. The router can extract single photons from the coherent input signal and directly modulate them into three different output channels. More importantly, the two output signal frequencies can be selected by adjusting the Coulomb coupling strength. For application purposes, we justify that there is insignificant influence from the vacuum and thermal noises on the performance of the router under cryogenic conditions. Our proposal may pave a new avenue towards multi-channel routers and quantum networks.

  15. A direct measurement of the Z sup 0 invisible width by single photon counting

    Energy Technology Data Exchange (ETDEWEB)

    Akrawy, M.Z.; Alexander, G.; Allison, J.; Allport, P.P.; Anderson, K.J.; Armitage, J.C.; Arnison, G.T.J.; Ashton, P.; Azuelos, G.; Baines, J.T.M.; Ball, A.H.; Banks, J.; Barker, G.J.; Barlow, R.J.; Batley, J.R.; Beaudoin, G.; Beck, A.; Becker, J.; Behnke, T.; Bell, K.W.; Bella, G.; Bethke, S.; Biebel, O.; Binder, U.; Boodworth, I.J.; Bock, P.; Breuker, H.; Brown, R.M.; Brun, R.; Buijs, A.; Burckhart, H.J.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, D.G.; Chrin, J.T.M.; Clarke, P.E.L.; Cohen, I.; Collins, W.J.; Conboy, J.E.; Couch, M.; Coupland, M.; Cuffiani, M.; Dado, S.; Dallavalle, G.M.; Jong, S. de; Debu, P.; Deninno, M.M.; Dieckmann, A.; Dittmar, M.; Dixit, M.S.; Duchovni, E.; Duerdoth, I.P.; Dumas, D.J.P.; Elcombe, P.A.; Estabrooks, P.G.; Etzion, E.; Fabbri, F.; Farthouat, P.; Fischer, H.M.; Fong, D.G.; French, M.T.; Fukunaga, C.; Gaidot, A.; Ganel, O.; Gary, J.W.; Gascon, J.; Geddes, N.I.; Gee, C.N.P.; Geich-Gimbel, C.; Gensler, S.W.; Gentit; OPAL Collaboration

    1991-05-01

    The OPAL detector at LEP is used to measure the branching ratio of the Z{sup 0} into invisible particles by measruing the cross section of single photon events in e{sup +}e{sup -} collisions at centre-of-mass energies near the Z{sup 0} resonance. In a data sample of 5.3 pb{sup -1}, we observe 73 events with single photons depositing more than 1.5 GeV in the electromagnetic calorimeter, with an expected background of 8+-2 events not associated with invisible Z{sup 0} decay. With this data we determine the Z{sup 0} invisible width to be 0.50+-0.07+-0.03 GeV, where the first error is statistical and the second systematic. This corresponds to 3.0+-0.4+-0.2 light neutrino generations in the Standard Model. (orig.).

  16. Resonant interaction of a single atom with single photons from a down-conversion source

    International Nuclear Information System (INIS)

    Schuck, C.; Rohde, F.; Piro, N.; Almendros, M.; Huwer, J.; Mitchell, M. W.; Hennrich, M.; Haase, A.; Dubin, F.; Eschner, J.

    2010-01-01

    We observe the interaction of a single trapped calcium ion with single photons produced by a narrow-band, resonant down-conversion source [A. Haase et al., Opt. Lett. 34, 55 (2009)], employing a quantum jump scheme. Using the temperature dependence of the down-conversion spectrum and the tunability of the narrow source, absorption of the down-conversion photons is quantitatively characterized.

  17. Controllable single-photon transport between remote coupled-cavity arrays

    OpenAIRE

    Qin, Wei; Nori, Franco

    2015-01-01

    We develop a new approach for controllable single-photon transport between two remote one-dimensional coupled-cavity arrays, used as quantum registers, mediated by an additional one-dimensional coupled-cavity array, acting as a quantum channel. A single two-level atom located inside one cavity of the intermediate channel is used to control the long-range coherent quantum coupling between two remote registers, thereby functioning as a quantum switch. With a time-independent perturbative treatm...

  18. Observation of quantum state collapse and revival due to the single-photon Kerr effect.

    Science.gov (United States)

    Kirchmair, Gerhard; Vlastakis, Brian; Leghtas, Zaki; Nigg, Simon E; Paik, Hanhee; Ginossar, Eran; Mirrahimi, Mazyar; Frunzio, Luigi; Girvin, S M; Schoelkopf, R J

    2013-03-14

    To create and manipulate non-classical states of light for quantum information protocols, a strong, nonlinear interaction at the single-photon level is required. One approach to the generation of suitable interactions is to couple photons to atoms, as in the strong coupling regime of cavity quantum electrodynamic systems. In these systems, however, the quantum state of the light is only indirectly controlled by manipulating the atoms. A direct photon-photon interaction occurs in so-called Kerr media, which typically induce only weak nonlinearity at the cost of significant loss. So far, it has not been possible to reach the single-photon Kerr regime, in which the interaction strength between individual photons exceeds the loss rate. Here, using a three-dimensional circuit quantum electrodynamic architecture, we engineer an artificial Kerr medium that enters this regime and allows the observation of new quantum effects. We realize a gedanken experiment in which the collapse and revival of a coherent state can be observed. This time evolution is a consequence of the quantization of the light field in the cavity and the nonlinear interaction between individual photons. During the evolution, non-classical superpositions of coherent states (that is, multi-component 'Schrödinger cat' states) are formed. We visualize this evolution by measuring the Husimi Q function and confirm the non-classical properties of these transient states by cavity state tomography. The ability to create and manipulate superpositions of coherent states in such a high-quality-factor photon mode opens perspectives for combining the physics of continuous variables with superconducting circuits. The single-photon Kerr effect could be used in quantum non-demolition measurement of photons, single-photon generation, autonomous quantum feedback schemes and quantum logic operations.

  19. Effect of Loss on Multiplexed Single-Photon Sources (Open Access Publisher’s Version)

    Science.gov (United States)

    2015-04-28

    theCreative CommonsAttribution 3.0 licence . Any further distribution of this workmustmaintain attribution to the author(s) and the title of thework...themultiplexed (MUX) single-photon source [14], which uses an array ofHSPSs, delay lines, electronics for classical logic operations , and an active...the squeezing parameter or the loss in the idler arm. In section 3wewill show that a practicalmultiplexed sourcewill require operation in the strong

  20. Rise time of voltage pulses in NbN superconducting single photon detectors

    International Nuclear Information System (INIS)

    Smirnov, K. V.; Divochiy, A. V.; Karpova, U. V.; Morozov, P. V.; Vakhtomin, Yu. B.; Seleznev, V. A.; Sidorova, M. V.; Zotova, A. N.; Vodolazov, D. Yu.

    2016-01-01

    We have found experimentally that the rise time of voltage pulse in NbN superconducting single photon detectors increases nonlinearly with increasing the length of the detector L. The effect is connected with dependence of resistance of the detector R n , which appears after photon absorption, on its kinetic inductance L k and, hence, on the length of the detector. This conclusion is confirmed by our calculations in the framework of two temperature model.

  1. Degenerative dementia: nosological aspects and results of single photon emission computed tomography

    International Nuclear Information System (INIS)

    Dubois, B.; Habert, M.O.

    1999-01-01

    Ten years ago, the diagnosis discussion of a dementia case for the old patient was limited to two pathologies: the Alzheimer illness and the Pick illness. During these last years, the frame of these primary degenerative dementia has fallen into pieces. The different diseases and the results got with single photon emission computed tomography are discussed. for example: fronto-temporal dementia, primary progressive aphasia, progressive apraxia, visio-spatial dysfunction, dementia at Lewy's bodies, or cortico-basal degeneration. (N.C.)

  2. Diagnostic merits of current and potential applications of single photon and positron imaging: a perspective

    Energy Technology Data Exchange (ETDEWEB)

    Harper, P. V.

    1978-01-01

    A brief review of the limitations of medical radionuclide imaging techniques in competition with x-ray CAT scanning and ultrasound suggest that the emphasis in this are should be on measurement of the physiologic uptake of tracer materials. Tomography greatly improves the possibilities of quantitation of this uptake - examples using positron and single photon techniques are presented for /sup 13/NH/sub 3/ and /sup 201/Tl in the heart.

  3. RETRACTED: Quantum key distribution without sharing reference frame using single photon rotational-invariant subspace

    Science.gov (United States)

    Chen, Dong-Xu; Liu, Rui-Feng; Zhang, Pei; Li, Hong-Rong; Gao, Hong; Li, Fu-Li

    2013-11-01

    We report an experimental proposal of quantum key distribution without sharing reference frame by using single photon rotational-invariant subspace. The rotational-invariant subspace is achieved by taking advantage of photon's spin-orbital composite states. Our scheme is simple and can be developed as a compact QKD system under current technology. Earth-to-satellite QKD is an emerging scenario that will benefit from our protocol.

  4. Rise time of voltage pulses in NbN superconducting single photon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, K. V. [Moscow State Pedagogical University, 1 Malaya Pirogovskaya St., 119435 Moscow (Russian Federation); CJSC “Superconducting Nanotechnology” (Scontel), 5/22-1 Rossolimo St., 119021 Moscow (Russian Federation); National Research University Higher School of Economics, Moscow Institute of Electronics and Mathematics, 34 Tallinskaya St., 109028 Moscow (Russian Federation); Divochiy, A. V.; Karpova, U. V.; Morozov, P. V. [CJSC “Superconducting Nanotechnology” (Scontel), 5/22-1 Rossolimo St., 119021 Moscow (Russian Federation); Vakhtomin, Yu. B.; Seleznev, V. A. [Moscow State Pedagogical University, 1 Malaya Pirogovskaya St., 119435 Moscow (Russian Federation); CJSC “Superconducting Nanotechnology” (Scontel), 5/22-1 Rossolimo St., 119021 Moscow (Russian Federation); Sidorova, M. V. [Moscow State Pedagogical University, 1 Malaya Pirogovskaya St., 119435 Moscow (Russian Federation); Zotova, A. N.; Vodolazov, D. Yu. [Institute for Physics of Microstructure, Russian Academy of Sciences, GSP-105, 603950 Nizhny Novgorod (Russian Federation); Lobachevsky State University of Nizhny Novgorod, 23 Gagarin Avenue, 603950 Nizhny Novgorod (Russian Federation)

    2016-08-01

    We have found experimentally that the rise time of voltage pulse in NbN superconducting single photon detectors increases nonlinearly with increasing the length of the detector L. The effect is connected with dependence of resistance of the detector R{sub n}, which appears after photon absorption, on its kinetic inductance L{sub k} and, hence, on the length of the detector. This conclusion is confirmed by our calculations in the framework of two temperature model.

  5. Evaluation of a 99Tcm bound brain scanning agent for single photon emission computed tomography

    DEFF Research Database (Denmark)

    Andersen, A R; Hasselbalch, S G; Paulson, O B

    1986-01-01

    D,L HM-PAO-99Tcm (PAO) is a lipophilic tracer complex which is avidly taken up by the brain. We have compared the regional distribution of PAO with regional cerebral blood flow (CBF). CBF was measured by single photon emission computed tomography (SPECT) by Tomomatic 64 after 133Xe inhalation in ...... of the (decay corrected) brain counts were lost during 24 hours....

  6. Setting Single Photon Detectors for Use with an Entangled Photon Distribution System

    Science.gov (United States)

    2017-12-01

    System by Daniel E Jones, Drew Weninger, and Michael Brodsky Approved for public release; distribution is unlimited...Laboratory Setting Single Photon Detectors for Use with an Entangled Photon Distribution System by Daniel E Jones and Michael Brodsky Computational...Use with an Entangled Photon Distribution System 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Daniel E Jones

  7. Enhancing the brightness of electrically driven single-photon sources using color centers in silicon carbide

    Science.gov (United States)

    Khramtsov, Igor A.; Vyshnevyy, Andrey A.; Fedyanin, Dmitry Yu.

    2018-03-01

    Practical applications of quantum information technologies exploiting the quantum nature of light require efficient and bright true single-photon sources which operate under ambient conditions. Currently, point defects in the crystal lattice of diamond known as color centers have taken the lead in the race for the most promising quantum system for practical non-classical light sources. This work is focused on a different quantum optoelectronic material, namely a color center in silicon carbide, and reveals the physics behind the process of single-photon emission from color centers in SiC under electrical pumping. We show that color centers in silicon carbide can be far superior to any other quantum light emitter under electrical control at room temperature. Using a comprehensive theoretical approach and rigorous numerical simulations, we demonstrate that at room temperature, the photon emission rate from a p-i-n silicon carbide single-photon emitting diode can exceed 5 Gcounts/s, which is higher than what can be achieved with electrically driven color centers in diamond or epitaxial quantum dots. These findings lay the foundation for the development of practical photonic quantum devices which can be produced in a well-developed CMOS compatible process flow.

  8. Multiple-output microwave single-photon source using superconducting circuits with longitudinal and transverse couplings

    Science.gov (United States)

    Wang, Xin; Miranowicz, Adam; Li, Hong-Rong; Nori, Franco

    2016-11-01

    Single-photon devices at microwave frequencies are important for applications in quantum information processing and communication in the microwave regime. In this work we describe a proposal of a multioutput single-photon device. We consider two superconducting resonators coupled to a gap-tunable qubit via both its longitudinal and transverse degrees of freedom. Thus, this qubit-resonator coupling differs from the coupling in standard circuit quantum-electrodynamic systems described by the Jaynes-Cummings model. We demonstrate that an effective quadratic coupling between one of the normal modes and the qubit can be induced and this induced second-order nonlinearity is much larger than that for conventional Kerr-type systems exhibiting photon blockade. Assuming that a coupled normal mode is resonantly driven, we observe that the output fields from the resonators exhibit strong sub-Poissonian photon-number statistics and photon antibunching. Contrary to previous studies on resonant photon blockade, the first-excited state of our device is a pure single-photon Fock state rather than a polariton state, i.e., a highly hybridized qubit-photon state. In addition, it is found that the optical state truncation caused by the strong qubit-induced nonlinearity can lead to an entanglement between the two resonators, even in their steady state under the Markov approximation.

  9. Theoretical and experimental study of single particle tracking in extreme conditions: single photon imaging

    International Nuclear Information System (INIS)

    Cajgfinger, T.

    2012-10-01

    This manuscript presents my thesis on the high frame rate (500 frames / second) single-photon detector electron-bombarded CMOS (ebCMOS). The first section compares three ultra-sensitive detectors and their methods for improving photon sensitivity: the CMOS low noise (sCMOS), the electron-multiplying CCD (emCCD) with signal multiplication by pixel and the ebCMOS with amplification by applied electric field. The method developed to detect single photon impacts with intra-pixel resolution on the ebCMOS sensor is presented. The second section compares the localization accuracy of these detectors in extreme conditions of very low photon flux (<10 photons/frame). First the theoretical limit is calculated using the Cramer-Rao lower bound for significant parameter sets. An experimental comparison of the detectors is then described. The setup provides one or more point sources controlled in position, signal and background noise. The results allow a comparison of the experimental effectiveness, purity and localization accuracy. The last section describes two experiments with the ebCMOS camera. The first aims at tracking hundreds of quantum dots simultaneously at the Nanoptec center. The second focuses on the swimming of bacteria at the surface at the Joliot Curie Institute. The point sources tracking algorithm using single photons and the Kalman filter implementation developed for these experiments is also described. (author)

  10. Single-Photon Switching and Entanglement of Solid- State Qubits in an Integrated Nanophotonic System

    Science.gov (United States)

    Evans, Ruffin; Sipahigil, Alp; Sukachev, Denis; Burek, Michael; Borregaard, Johannes; Bhaskar, Mihir; Nguyen, Christian; Pacheco, Jose; Bielejec, Edward; Loncar, Marko; Lukin, Mikhail

    2017-04-01

    Efficient interfaces between photons and quantum emitters form the basis for quantum networks and enable optical nonlinearities at the single-photon level. We demonstrate a platform for scalable quantum nanophotonics based on silicon-vacancy (SiV) color centers coupled to diamond nanodevices. By placing SiV centers inside diamond photonic crystal cavities, we realize a quantum-optical switch controlled by a single color center. We control the switch using SiV metastable states and observe switching at the single-photon level. Raman transitions are used to realize a single-photon source with a tunable frequency and bandwidth in a diamond waveguide. By measuring intensity correlations of indistinguishable Raman photons emitted into a single waveguide, we observe quantum interference resulting from the superradiant emission of two entangled SiV centers. We also discuss current work to extend the coherence time of the SiV spin degree of freedom, engineer deterministic multi-emitter interactions via the cavity mode, and related work with the Germanium-Vacancy center.

  11. Simple Atomic Quantum Memory Suitable for Semiconductor Quantum Dot Single Photons.

    Science.gov (United States)

    Wolters, Janik; Buser, Gianni; Horsley, Andrew; Béguin, Lucas; Jöckel, Andreas; Jahn, Jan-Philipp; Warburton, Richard J; Treutlein, Philipp

    2017-08-11

    Quantum memories matched to single photon sources will form an important cornerstone of future quantum network technology. We demonstrate such a memory in warm Rb vapor with on-demand storage and retrieval, based on electromagnetically induced transparency. With an acceptance bandwidth of δf=0.66  GHz, the memory is suitable for single photons emitted by semiconductor quantum dots. In this regime, vapor cell memories offer an excellent compromise between storage efficiency, storage time, noise level, and experimental complexity, and atomic collisions have negligible influence on the optical coherences. Operation of the memory is demonstrated using attenuated laser pulses on the single photon level. For a 50 ns storage time, we measure η_{e2e}^{50  ns}=3.4(3)% end-to-end efficiency of the fiber-coupled memory, with a total intrinsic efficiency η_{int}=17(3)%. Straightforward technological improvements can boost the end-to-end-efficiency to η_{e2e}≈35%; beyond that, increasing the optical depth and exploiting the Zeeman substructure of the atoms will allow such a memory to approach near unity efficiency. In the present memory, the unconditional read-out noise level of 9×10^{-3} photons is dominated by atomic fluorescence, and for input pulses containing on average μ_{1}=0.27(4) photons, the signal to noise level would be unity.

  12. Simple Atomic Quantum Memory Suitable for Semiconductor Quantum Dot Single Photons

    Science.gov (United States)

    Wolters, Janik; Buser, Gianni; Horsley, Andrew; Béguin, Lucas; Jöckel, Andreas; Jahn, Jan-Philipp; Warburton, Richard J.; Treutlein, Philipp

    2017-08-01

    Quantum memories matched to single photon sources will form an important cornerstone of future quantum network technology. We demonstrate such a memory in warm Rb vapor with on-demand storage and retrieval, based on electromagnetically induced transparency. With an acceptance bandwidth of δ f =0.66 GHz , the memory is suitable for single photons emitted by semiconductor quantum dots. In this regime, vapor cell memories offer an excellent compromise between storage efficiency, storage time, noise level, and experimental complexity, and atomic collisions have negligible influence on the optical coherences. Operation of the memory is demonstrated using attenuated laser pulses on the single photon level. For a 50 ns storage time, we measure ηe2 e 50 ns=3.4 (3 )% end-to-end efficiency of the fiber-coupled memory, with a total intrinsic efficiency ηint=17 (3 )%. Straightforward technological improvements can boost the end-to-end-efficiency to ηe 2 e≈35 %; beyond that, increasing the optical depth and exploiting the Zeeman substructure of the atoms will allow such a memory to approach near unity efficiency. In the present memory, the unconditional read-out noise level of 9 ×10-3 photons is dominated by atomic fluorescence, and for input pulses containing on average μ1=0.27 (4 ) photons, the signal to noise level would be unity.

  13. Probabilistically cloning two single-photon states using weak cross-Kerr nonlinearities

    International Nuclear Information System (INIS)

    Zhang, Wen; Rui, Pinshu; Zhang, Ziyun; Yang, Qun

    2014-01-01

    By using quantum nondemolition detectors (QNDs) based on weak cross-Kerr nonlinearities, we propose an experimental scheme for achieving 1→2 probabilistic quantum cloning (PQC) of a single-photon state, secretly choosing from a two-state set. In our scheme, after a QND is performed on the to-be-cloned photon and the assistant photon, a single-photon projection measurement is performed by a polarization beam splitter (PBS) and two single-photon trigger detectors (SPTDs). The measurement is to judge whether the PQC should be continued. If the cloning fails, a cutoff is carried out and some operations are omitted. This makes our scheme economical. If the PQC is continued according to the measurement result, two more QNDs and some unitary operations are performed on the to-be-cloned photon and the cloning photon to achieve the PQC in a nearly deterministic way. Our experimental scheme for PQC is feasible for future technology. Furthermore, the quantum logic network of our PQC scheme is presented. In comparison with similar networks, our PQC network is simpler and more economical. (paper)

  14. High-speed bridge circuit for InGaAs avalanche photodiode single-photon detector

    Science.gov (United States)

    Hashimoto, Hirofumi; Tomita, Akihisa; Okamoto, Atsushi

    2014-02-01

    Because of low power consumption and small footprint, avalanche photodiodes (APD) have been commonly applied to photon detection. Recently, high speed quantum communication has been demonstrated for high bit-rate quantum key distribution. For the high speed quantum communication, photon detectors should operate at GHz-clock frequencies. We propose balanced detection circuits for GHz-clock operation of InGaAs-APD photon detectors. The balanced single photon detector operates with sinusoidal wave gating. The sinusoidal wave appearing in the output is removed by the subtraction from APD signal without sharp band-elimination filters. Omission of the sharp filters removes the constraint on the operating frequency of the single photon detector. We present two designs, one works with two identical APDs, the other with one APD and a low-pass filter. The sinusoidal gating enables to eliminate the gating noise even with the simple configuration of the latter design. We demonstrated the balanced single photon detector operating with 1.020GHz clock at 233 K, 193 K, and 186.5 K. The dark count probability was 4.0 x 10-4 counts/pulse with the quantum efficiency of 10% at 233K, and 1.6 x 10-4 counts/pulse at 186.5 K. These results were obtained with easily available APDs (NR8300FP-C.C, RENESASS) originally developed for optical time-domain reflectmeters.

  15. High-dimensional quantum key distribution with the entangled single-photon-added coherent state

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yang [Zhengzhou Information Science and Technology Institute, Zhengzhou, 450001 (China); Synergetic Innovation Center of Quantum Information and Quantum Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Bao, Wan-Su, E-mail: 2010thzz@sina.com [Zhengzhou Information Science and Technology Institute, Zhengzhou, 450001 (China); Synergetic Innovation Center of Quantum Information and Quantum Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Bao, Hai-Ze; Zhou, Chun; Jiang, Mu-Sheng; Li, Hong-Wei [Zhengzhou Information Science and Technology Institute, Zhengzhou, 450001 (China); Synergetic Innovation Center of Quantum Information and Quantum Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2017-04-25

    High-dimensional quantum key distribution (HD-QKD) can generate more secure bits for one detection event so that it can achieve long distance key distribution with a high secret key capacity. In this Letter, we present a decoy state HD-QKD scheme with the entangled single-photon-added coherent state (ESPACS) source. We present two tight formulas to estimate the single-photon fraction of postselected events and Eve's Holevo information and derive lower bounds on the secret key capacity and the secret key rate of our protocol. We also present finite-key analysis for our protocol by using the Chernoff bound. Our numerical results show that our protocol using one decoy state can perform better than that of previous HD-QKD protocol with the spontaneous parametric down conversion (SPDC) using two decoy states. Moreover, when considering finite resources, the advantage is more obvious. - Highlights: • Implement the single-photon-added coherent state source into the high-dimensional quantum key distribution. • Enhance both the secret key capacity and the secret key rate compared with previous schemes. • Show an excellent performance in view of statistical fluctuations.

  16. Ultra-structural cell distribution of the melanoma marker iodobenzamide: improved potentiality of SIMS imaging in life sciences

    Directory of Open Access Journals (Sweden)

    Papon Janine

    2004-04-01

    Full Text Available Abstract Background Analytical imaging by secondary ion mass spectrometry (SIMS provides images representative of the distribution of a specific ion within a sample surface. For the last fifteen years, concerted collaborative research to design a new ion microprobe with high technical standards in both mass and lateral resolution as well as in sensitivity has led to the CAMECA NanoSims 50, recently introduced onto the market. This instrument has decisive capabilities, which allow biological applications of SIMS microscopy at a level previously inaccessible. Its potential is illustrated here by the demonstration of the specific affinity of a melanoma marker for melanin. This finding is of great importance for the diagnosis and/or treatment of malignant melanoma, a tumour whose worldwide incidence is continuously growing. Methods The characteristics of the instrument are briefly described and an example of application is given. This example deals with the intracellular localization of an iodo-benzamide used as a diagnostic tool for the scintigraphic detection of melanic cells (e.g. metastasis of malignant melanoma. B16 melanoma cells were injected intravenously to C57BL6/J1/co mice. Multiple B16 melanoma colonies developed in the lungs of treated animals within three weeks. Iodobenzamide was injected intravenously in tumour bearing mice six hours before sacrifice. Small pieces of lung were prepared for SIMS analysis. Results Mouse lung B16 melanoma colonies were observed with high lateral resolution. Cyanide ions gave "histological" images of the cell, representative of the distribution of C and N containing molecules (e.g. proteins, nucleic acids, melanin, etc. while phosphorus ions are mainly produced by nucleic acids. Iodine was detected only in melanosomes, confirming the specific affinity of the drug for melanin. No drug was found in normal lung tissue. Conclusion This study demonstrates the potential of SIMS microscopy, which allows the

  17. Efficient frequency downconversion at the single photon level from the red spectral range to the telecommunications C-band.

    Science.gov (United States)

    Zaske, Sebastian; Lenhard, Andreas; Becher, Christoph

    2011-06-20

    We report on single photon frequency downconversion from the red part of the spectrum (738 nm) to the telecommunications C-band. By mixing attenuated laser pulses with an average photon number per pulse telecommunications wavelengths.

  18. The associated charged particle multiplicity of high-p/sub T/ pi /sup 0/ and single-photon events

    CERN Document Server

    Diakonou, M; Albrow, M G; Almehed, S; Benary, O; Bøggild, H; Botner, O; Cnops, A M; Cockerill, D J A; Dagan, S; Dahl-Jensen, Erik; Dahl-Jensen, I; Damgaard, G; Fabjan, Christian Wolfgang; Filippas-Tassos, A; Fokitis, E; Fowler, E C; Hallgren, A; Hansen, K H; Henning, S; Hood, D M; Hooper, J; Jarlskog, G; Karpathopoulos, S; Killian, T; Kourkoumelis, C; Kreisler, M; Lissauer, D; Lörstad, B; Ludlam, T; Mannelli, I; McCubbin, N A; Melin, A; Mjörnmark, U; Møller, R; Molzon, W; Mouzourakis, P; Nielsen, B S; Nielsen, S O; Nilsson, A; Oren, Y; Palmer, R B; Rahm, David Charles; Rehak, P; Resvanis, L K; Rosselt, L; Schistad, B; Stumer, I; Svensson, L; von Dardel, Guy F; Willis, W J

    1980-01-01

    The associated charged particle multiplicities of high-p/sub T/ pi /sup 0/ and single-photon events were measured at the CERN intersecting storage rings using lead/liquid-argon calorimeters and a scintillation counter array placed around the intersection region. The average multiplicity on the trigger side for the single-photon events was found to be significantly lower than that for the pi /sup 0/ events. The away-side multiplicity for both pi /sup 0/ and single- photon events increases with the trigger particle p/sub T/, but, at a fixed p/sub T/, the direct photon sample was found to have a slightly lower average multiplicity. The differences in the event structure can be explained if a large fraction of the single photons are produced via qg to gamma q constituent scattering. (16 refs).

  19. Single photon detection and signal analysis for high sensitivity dosimetry based on optically stimulated luminescence with beryllium oxide

    Science.gov (United States)

    Radtke, J.; Sponner, J.; Jakobi, C.; Schneider, J.; Sommer, M.; Teichmann, T.; Ullrich, W.; Henniger, J.; Kormoll, T.

    2018-01-01

    Single photon detection applied to optically stimulated luminescence (OSL) dosimetry is a promising approach due to the low level of luminescence light and the known statistical behavior of single photon events. Time resolved detection allows to apply a variety of different and independent data analysis methods. Furthermore, using amplitude modulated stimulation impresses time- and frequency information into the OSL light and therefore allows for additional means of analysis. Considering the impressed frequency information, data analysis by using Fourier transform algorithms or other digital filters can be used for separating the OSL signal from unwanted light or events generated by other phenomena. This potentially lowers the detection limits of low dose measurements and might improve the reproducibility and stability of obtained data. In this work, an OSL system based on a single photon detector, a fast and accurate stimulation unit and an FPGA is presented. Different analysis algorithms which are applied to the single photon data are discussed.

  20. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs

    OpenAIRE

    Mejia, J.; Reis, M.A.; Miranda, A.C.C.; Batista, I.R.; Barboza, M.R.F.; Shih, M.C.; Fu, G.; Chen, C.T.; Meng, L.J.; Bressan, R.A.; Amaro Jr, E.

    2013-01-01

    The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and ...

  1. An improved synthesis of [125I]N-(diethylaminoethyl)-4-iodobenzamide: a potential ligand for imaging malignant melanoma

    International Nuclear Information System (INIS)

    John, C.S.; Reba, R.C.; Varma, V.M.; McAfee, J.G.; Saga, T.; Kinuya, S.; Le, N.; Jeong, J.M.; Paik, C.H.

    1993-01-01

    To improve the radiolabeling yield and the specific activity of [ 125 I]N-(2-diethylaminoethyl)-4-iodobenzamide(DAB), the aryltributyltin precursor was synthesized from the N-(2-diethylaminoethyl)-4-bromobenzamide derivative by palladium catalyzed stannylation using bis(tributyltin). The radiolabeled product, [ 125 I]DAB, was obtained by an iododestannylation reaction in high radiochemical yields (85-94%, radiochemical purity, > 98%) using chloramine-T as an oxidizing agent. The specific activity was greater than 1600 Ci/mmol. The biodistribution studies in nude mice implanted with human malignant melanoma xenograft showed a good tumor uptake (6.14% ID/g at 1 h, 2.81% ID/g at 6 h and 0.42% ID/g at 24 h) of [ 125 I]DAB. Unfortunately, a high uptake in the non-target organs, such as liver and lung was found. At 1 h post-injection the activity level in liver and lung was 11.76 and 7.58% ID/g, respectively. A slow clearance of activity from liver and lung was observed at 6 h (3.43 and 0.49% ID/g). These results demonstrate that iodinated IDAB is a potential radiopharmaceutical for the management of patients with malignant melanoma. (Author)

  2. An improved synthesis of [[sup 125]I]N-(diethylaminoethyl)-4-iodobenzamide: a potential ligand for imaging malignant melanoma

    Energy Technology Data Exchange (ETDEWEB)

    John, C.S.; Reba, R.C.; Varma, V.M.; McAfee, J.G. (Georgetown Univ. Medical Center, Washington, DC (United States)); Saga, T.; Kinuya, S.; Le, N.; Jeong, J.M.; Paik, C.H. (National Insts. of Health, Bethesda, MD (United States))

    1993-01-01

    To improve the radiolabeling yield and the specific activity of [[sup 125]I]N-(2-diethylaminoethyl)-4-iodobenzamide(DAB), the aryltributyltin precursor was synthesized from the N-(2-diethylaminoethyl)-4-bromobenzamide derivative by palladium catalyzed stannylation using bis(tributyltin). The radiolabeled product, [[sup 125]I]DAB, was obtained by an iododestannylation reaction in high radiochemical yields (85-94%, radiochemical purity, > 98%) using chloramine-T as an oxidizing agent. The specific activity was greater than 1600 Ci/mmol. The biodistribution studies in nude mice implanted with human malignant melanoma xenograft showed a good tumor uptake (6.14% ID/g at 1 h, 2.81% ID/g at 6 h and 0.42% ID/g at 24 h) of [[sup 125]I]DAB. Unfortunately, a high uptake in the non-target organs, such as liver and lung was found. At 1 h post-injection the activity level in liver and lung was 11.76 and 7.58% ID/g, respectively. A slow clearance of activity from liver and lung was observed at 6 h (3.43 and 0.49% ID/g). These results demonstrate that iodinated IDAB is a potential radiopharmaceutical for the management of patients with malignant melanoma. (Author).

  3. High-performance imaging of stem cells using single-photon emissions

    Science.gov (United States)

    Wagenaar, Douglas J.; Moats, Rex A.; Hartsough, Neal E.; Meier, Dirk; Hugg, James W.; Yang, Tang; Gazit, Dan; Pelled, Gadi; Patt, Bradley E.

    2011-10-01

    Radiolabeled cells have been imaged for decades in the field of autoradiography. Recent advances in detector and microelectronics technologies have enabled the new field of "digital autoradiography" which remains limited to ex vivo specimens of thin tissue slices. The 3D field-of-view (FOV) of single cell imaging can be extended to millimeters if the low energy (10-30 keV) photon emissions of radionuclides are used for single-photon nuclear imaging. This new microscope uses a coded aperture foil made of highly attenuating elements such as gold or platinum to form the image as a kind of "lens". The detectors used for single-photon emission microscopy are typically silicon detectors with a pixel pitch less than 60 μm. The goal of this work is to image radiolabeled mesenchymal stem cells in vivo in an animal model of tendon repair processes. Single-photon nuclear imaging is an attractive modality for translational medicine since the labeled cells can be imaged simultaneously with the reparative processes by using the dual-isotope imaging technique. The details our microscope's two-layer gold aperture and the operation of the energy-dispersive, pixellated silicon detector are presented along with the first demonstration of energy discrimination with a 57Co source. Cell labeling techniques have been augmented by genetic engineering with the sodium-iodide symporter, a type of reporter gene imaging method that enables in vivo uptake of free 99mTc or an iodine isotope at a time point days or weeks after the insertion of the genetically modified stem cells into the animal model. This microscopy work in animal research may expand to the imaging of reporter-enabled stem cells simultaneously with the expected biological repair process in human clinical trials of stem cell therapies.

  4. Single photon detection and localization accuracy with an ebCMOS camera

    Energy Technology Data Exchange (ETDEWEB)

    Cajgfinger, T. [CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, Villeurbanne F-69622 (France); Dominjon, A., E-mail: agnes.dominjon@nao.ac.jp [Université de Lyon, Université de Lyon 1, Lyon 69003 France. (France); Barbier, R. [CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, Villeurbanne F-69622 (France); Université de Lyon, Université de Lyon 1, Lyon 69003 France. (France)

    2015-07-01

    The CMOS sensor technologies evolve very fast and offer today very promising solutions to existing issues facing by imaging camera systems. CMOS sensors are very attractive for fast and sensitive imaging thanks to their low pixel noise (1e-) and their possibility of backside illumination. The ebCMOS group of IPNL has produced a camera system dedicated to Low Light Level detection and based on a 640 kPixels ebCMOS with its acquisition system. After reminding the principle of detection of an ebCMOS and the characteristics of our prototype, we confront our camera to other imaging systems. We compare the identification efficiency and the localization accuracy of a point source by four different photo-detection devices: the scientific CMOS (sCMOS), the Charge Coupled Device (CDD), the Electron Multiplying CCD (emCCD) and the Electron Bombarded CMOS (ebCMOS). Our ebCMOS camera is able to identify a single photon source in less than 10 ms with a localization accuracy better than 1 µm. We report as well efficiency measurement and the false positive identification of the ebCMOS camera by identifying more than hundreds of single photon sources in parallel. About 700 spots are identified with a detection efficiency higher than 90% and a false positive percentage lower than 5. With these measurements, we show that our target tracking algorithm can be implemented in real time at 500 frames per second under a photon flux of the order of 8000 photons per frame. These results demonstrate that the ebCMOS camera concept with its single photon detection and target tracking algorithm is one of the best devices for low light and fast applications such as bioluminescence imaging, quantum dots tracking or adaptive optics.

  5. Brain receptor single-photon emission computer tomography with 123I Datscan in Parkinson's disease

    International Nuclear Information System (INIS)

    Minchev, D.; Peshev, N.; Kostadinova, I.; Grigorova, O.; Trindev, P.; Shotekov, P.

    2005-01-01

    Clinical aspects of Parkinson's disease are not enough for the early diagnosis of the disease. Positron emission tomography and the receptor single - photon emission tomography can be used for imaging functional integrity of nigrostriatal dopaminergic structures. 24 patient (17 men and 7 women) were investigated. 20 of them are with Parkinson's disease and 4 are with essential tremor. The radiopharmaceutical - 123I-Datscan (ioflupane, bind with 123I) represent a cocaine analogue with selective affinity to dopamine transporters, located in the dopaminergic nigrostriatal terminals in the striatum. Single - photon emission computer tomography was performed with SPECT gamma camera (ADAC, SH Epic detector). The scintigraphic study was made 3 to 6 hours after intravenous injection of the radiopharmaceutical - 123I- Datscan in dose 185 MBq. 120 frames are registered with duration of each one 22 seconds and gamma camera rotation 360. After generation of transversal slices we generated two composites pictures. The first composite picture image the striatum, the second - the occipital region. Two ratios were calculated representing the uptake of the radiopharmaceutical in the left and right striatum. Qualitative and quantitative criteria were elaborated for evaluating the scintigraphic patterns. Decreased, nonhomogeneous and asymmetric uptake of the radiopharmaceutical coupled with low quantitative parameters in range from 1.44 to 2.87 represents the characteristic scintigraphic pattern for Parkinson's disease with clear clinical picture. Homogenous with high intensity and symmetric uptake of the radiopharmaceutical in the striatum coupled with his clear frontier and with quantitative parameters up to 4.40 represent the scintigraphic pattern in two patients with essential tremor. Receptor single - photon emission computer tomography with 123I - Datscan represents an accurate nuclear-medicine method for precise diagnosis of Parkinson's disease and for its differentiation from

  6. Single-Photon Interference due to Motion in an Atomic Collective Excitation

    Science.gov (United States)

    Whiting, D. J.; Šibalić, N.; Keaveney, J.; Adams, C. S.; Hughes, I. G.

    2017-06-01

    We experimentally demonstrate the heralded generation of bichromatic single photons from an atomic collective spin excitation (CSE). The photon arrival times display collective quantum beats, a novel interference effect resulting from the relative motion of atoms in the CSE. A combination of velocity-selective excitation with strong laser dressing and the addition of a magnetic field allows for exquisite control of this collective beat phenomenon. The present experiment uses a diamond scheme with near-IR photons that can be extended to include telecommunications wavelengths or modified to allow storage and retrieval in an inverted-Y scheme.

  7. Channel analysis for single photon underwater free space quantum key distribution.

    Science.gov (United States)

    Shi, Peng; Zhao, Shi-Cheng; Gu, Yong-Jian; Li, Wen-Dong

    2015-03-01

    We investigate the optical absorption and scattering properties of underwater media pertinent to our underwater free space quantum key distribution (QKD) channel model. With the vector radiative transfer theory and Monte Carlo method, we obtain the attenuation of photons, the fidelity of the scattered photons, the quantum bit error rate, and the sifted key generation rate of underwater quantum communication. It can be observed from our simulations that the most secure single photon underwater free space QKD is feasible in the clearest ocean water.

  8. Oxide-apertured microcavity single-photon-emitting diodes-simultaneous confinement of current and light

    International Nuclear Information System (INIS)

    Ellis, David J P; Bennett, Anthony J; Dewhurst, Samuel J; Shields, Andrew J; Atkinson, Paola; Nicoll, Christine A; Ritchie, David A

    2008-01-01

    We report on the development of a generation of microcavity single-photon sources in which an aluminium oxide aperture provides simultaneous confinement of the injected current and the optical mode. The aperture is formed by the wet oxidation of an aluminium-rich AlGaAs layer. This approach allows a high quality cavity to be successfully integrated into an electrical device, from which enhanced photon emission is observed through the Purcell effect. The resulting source demonstrated an improved photon collection efficiency and was shown to operate at repetition rates in excess of 0.5 GHz.

  9. Indistinguishable and efficient single photons from a quantum dot in a planar nanobeam waveguide

    DEFF Research Database (Denmark)

    Kirsanské, Gabija; Nielsen, Henri Thyrrestrup; Daveau, Raphaël Sura

    2017-01-01

    We demonstrate a high-purity source of indistinguishable single photons using a quantum dot embedded in a nanophotonic waveguide. The source features a near-unity internal coupling efficiency and the collected photons are efficiently coupled off chip by implementing a taper that adiabatically...... allows pinpointing the residual decoherence processes, notably the effect of phonon broadening. Strict resonant excitation is implemented as well as another means of suppressing photon jitter, and the additional complexity of suppressing the excitation laser source is addressed. The paper opens a clear...

  10. Nano-optical observation of cascade switching in a parallel superconducting nanowire single photon detector

    International Nuclear Information System (INIS)

    Heath, Robert M.; Tanner, Michael G.; Casaburi, Alessandro; Hadfield, Robert H.; Webster, Mark G.; San Emeterio Alvarez, Lara; Jiang, Weitao; Barber, Zoe H.; Warburton, Richard J.

    2014-01-01

    The device physics of parallel-wire superconducting nanowire single photon detectors is based on a cascade process. Using nano-optical techniques and a parallel wire device with spatially separate pixels, we explicitly demonstrate the single- and multi-photon triggering regimes. We develop a model for describing efficiency of a detector operating in the arm-trigger regime. We investigate the timing response of the detector when illuminating a single pixel and two pixels. We see a change in the active area of the detector between the two regimes and find the two-pixel trigger regime to have a faster timing response than the one-pixel regime

  11. Space-qualified silicon avalanche-photodiode single-photon-counting modules

    Science.gov (United States)

    Sun, Xiaoli; Krainak, Michael A.; Abshire, James B.; Spinhirne, James D.; Trottier, Claude; Davies, Murray; Dautet, Henri; Allan, Graham R.; Lukemire, Alan T.; Vandiver, James C.

    2004-09-01

    A space-qualified silicon avalanche-photodiode (APD) based single-photon-counting-module (SPCM) was developed for the Geoscience Laser Altimeter System (GLAS) on board NASA's Ice, Cloud, and Land Elevation Satellite (ICESat). Numerous improvements were made over the commercially available SPCMs in both performance and reliability. The measured optoelectronic parameters include, 65% photon detection efficiency at the 532 nm wavelength, 15-17 mega-counts per second (Mcps) maximum count rate and less than 200 s-1 dark counts before exposure to space radiation.

  12. Wavevector multiplexed atomic quantum memory via spatially-resolved single-photon detection.

    Science.gov (United States)

    Parniak, Michał; Dąbrowski, Michał; Mazelanik, Mateusz; Leszczyński, Adam; Lipka, Michał; Wasilewski, Wojciech

    2017-12-15

    Parallelized quantum information processing requires tailored quantum memories to simultaneously handle multiple photons. The spatial degree of freedom is a promising candidate to facilitate such photonic multiplexing. Using a single-photon resolving camera, we demonstrate a wavevector multiplexed quantum memory based on a cold atomic ensemble. Observation of nonclassical correlations between Raman scattered photons is confirmed by an average value of the second-order correlation function [Formula: see text] in 665 separated modes simultaneously. The proposed protocol utilizing the multimode memory along with the camera will facilitate generation of multi-photon states, which are a necessity in quantum-enhanced sensing technologies and as an input to photonic quantum circuits.

  13. Bronchobiliary Fistula Localized by Cholescintigraphy with Single-Photon Emission Computed Tomography

    International Nuclear Information System (INIS)

    Artunduaga, Maddy; Patel, Niraj R.; Wendt, Julie A.; Guy, Elizabeth S.; Nachiappan, Arun C.

    2015-01-01

    Biliptysis is an important clinical feature to recognize as it is associated with bronchobiliary fistula, a rare entity. Bronchobiliary fistulas have been diagnosed with planar cholescintigraphy. However, cholescintigraphy with single-photon emission computed tomography (SPECT) can better spatially localize a bronchobiliary fistula as compared to planar cholescintigraphy alone, and is useful for preoperative planning if surgical treatment is required. Here, we present the case of a 23-year-old male who developed a bronchobiliary fistula in the setting of posttraumatic and postsurgical infection, which was diagnosed and localized by cholescintigraphy with SPECT

  14. Search for new phenomena using single photon events in the DELPHI detector at LEP

    CERN Document Server

    Abreu, P; Adye, T; Agasi, E; Ajinenko, I; Aleksan, Roy; Alekseev, G D; Alemany, R; Allport, P P; Almehed, S; Amaldi, Ugo; Amato, S; Andreazza, A; Andrieux, M L; Antilogus, P; Apel, W D; Arnoud, Y; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Bambade, P; Barão, F; Barate, R; Barbi, M S; Barbiellini, Guido; Bardin, Dimitri Yuri; Baroncelli, A; Bärring, O; Barrio, J A; Bartl, Walter; Bates, M J; Battaglia, Marco; Baubillier, M; Baudot, J; Becks, K H; Begalli, M; Beillière, P; Belokopytov, Yu A; Belous, K S; Benvenuti, Alberto C; Berggren, M; Bertrand, D; Bianchi, F; Bigi, M; Bilenky, S M; Billoir, P; Bloch, D; Blume, M; Blyth, S; Bolognese, T; Bonesini, M; Bonivento, W; Booth, P S L; Borisov, G; Bosio, C; Bosworth, S; Botner, O; Boudinov, E; Bouquet, B; Bourdarios, C; Bowcock, T J V; Bozzo, M; Branchini, P; Brand, K D; Brenke, T; Brenner, R A; Bricman, C; Brillault, L; Brown, R C A; Brückman, P; Brunet, J M; Bugge, L; Buran, T; Burgsmüller, T; Buschmann, P; Buys, A; Cabrera, S; Caccia, M; Calvi, M; Camacho-Rozas, A J; Camporesi, T; Canale, V; Canepa, M; Cankocak, K; Cao, F; Carena, F; Carroll, L; Caso, Carlo; Castillo-Gimenez, M V; Cattai, A; Cavallo, F R; Cerrito, L; Chabaud, V; Charpentier, P; Chaussard, L; Chauveau, J; Checchia, P; Chelkov, G A; Chen, M; Chierici, R; Chliapnikov, P V; Chochula, P; Chorowicz, V; Cindro, V; Collins, P; Contreras, J L; Contri, R; Cortina, E; Cosme, G; Cossutti, F; Crawley, H B; Crennell, D J; Crosetti, G; Cuevas-Maestro, J; Czellar, S; Dahl-Jensen, Erik; Dahm, J; D'Almagne, B; Dam, M; Damgaard, G; Dauncey, P D; Davenport, Martyn; Da Silva, W; Defoix, C; Deghorain, A; Della Ricca, G; Delpierre, P A; Demaria, N; De Angelis, A; de Boer, Wim; De Brabandere, S; De Clercq, C; La Vaissière, C de; De Lotto, B; De Min, A; De Paula, L S; De Saint-Jean, C; Dijkstra, H; Di Ciaccio, Lucia; Djama, F; Dolbeau, J; Dönszelmann, M; Doroba, K; Dracos, M; Drees, J; Drees, K A; Dris, M; Dufour, Y; Edsall, D M; Ehret, R; Eigen, G; Ekelöf, T J C; Ekspong, Gösta; Elsing, M; Engel, J P; Ershaidat, N; Erzen, B; Espirito-Santo, M C; Falk, E; Fassouliotis, D; Feindt, Michael; Fenyuk, A; Ferrer, A; Filippas-Tassos, A; Firestone, A; Fischer, P A; Föth, H; Fokitis, E; Fontanelli, F; Formenti, F; Franek, B J; Frenkiel, P; Fries, D E C; Frodesen, A G; Frühwirth, R; Fulda-Quenzer, F; Fuster, J A; Galloni, A; Gamba, D; Gandelman, M; García, C; García, J; Gaspar, C; Gasparini, U; Gavillet, P; Gazis, E N; Gelé, D; Gerber, J P; Gerdyukov, L N; Gibbs, M; Gokieli, R; Golob, B; Gopal, Gian P; Gorn, L; Górski, M; Guz, Yu; Gracco, Valerio; Graziani, E; Grosdidier, G; Grzelak, K; Gumenyuk, S A; Gunnarsson, P; Günther, M; Guy, J; Hahn, F; Hahn, S; Hajduk, Z; Hallgren, A; Hamacher, K; Hao, W; Harris, F J; Hedberg, V; Hernández, J J; Herquet, P; Herr, H; Hessing, T L; Higón, E; Hilke, Hans Jürgen; Hill, T S; Holmgren, S O; Holt, P J; Holthuizen, D J; Hoorelbeke, S; Houlden, M A; Huet, K; Hultqvist, K; Jackson, J N; Jacobsson, R; Jalocha, P; Janik, R; Jarlskog, C; Jarlskog, G; Jarry, P; Jean-Marie, B; Johansson, E K; Jönsson, L B; Jönsson, P E; Joram, Christian; Juillot, P; Kaiser, M; Kapusta, F; Karafasoulis, K; Karlsson, M; Karvelas, E; Katsanevas, S; Katsoufis, E C; Keränen, R; Khokhlov, Yu A; Khomenko, B A; Khovanskii, N N; King, B J; Kjaer, N J; Klein, H; Klovning, A; Kluit, P M; Köne, B; Kokkinias, P; Koratzinos, M; Korcyl, K; Kourkoumelis, C; Kuznetsov, O; Kramer, P H; Krammer, Manfred; Kreuter, C; Kronkvist, I J; Krumshtein, Z; Krupinski, W; Kubinec, P; Kucewicz, W; Kurvinen, K L; Lacasta, C; Laktineh, I; Lamblot, S; Lamsa, J; Lanceri, L; Lane, D W; Langefeld, P; Last, I; Laugier, J P; Lauhakangas, R; Leder, Gerhard; Ledroit, F; Lefébure, V; Legan, C K; Leitner, R; Lemoigne, Y; Lemonne, J; Lenzen, Georg; Lepeltier, V; Lesiak, T; Liko, D; Lindner, R; Lipniacka, A; Lippi, I; Lörstad, B; Lokajícek, M; Loken, J G; López, J M; Loukas, D; Lutz, P; Lyons, L; MacNaughton, J N; Maehlum, G; Maio, A; Malychev, V; Mandl, F; Marco, J; Marco, R P; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Maron, T; Martínez-Rivero, C; Martínez-Vidal, F; Martí i García, S; Matorras, F; Matteuzzi, C; Matthiae, Giorgio; Mazzucato, M; McCubbin, M L; McKay, R; McNulty, R; Medbo, J; Merk, M; Meroni, C; Meyer, S; Meyer, W T; Michelotto, M; Migliore, E; Mirabito, L; Mitaroff, Winfried A; Mjörnmark, U; Moa, T; Møller, R; Mönig, K; Monge, M R; Morettini, P; Müller, H; Mundim, L M; Murray, W J; Muryn, B; Myatt, Gerald; Naraghi, F; Navarria, Francesco Luigi; Navas, S; Nawrocki, K; Negri, P; Némécek, S; Neumann, W; Neumeister, N; Nicolaidou, R; Nielsen, B S; Nieuwenhuizen, M; Nikolaenko, V; Niss, P; Nomerotski, A; Normand, Ainsley; Oberschulte-Beckmann, W; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, Risto; Österberg, K; Ouraou, A; Paganini, P; Paganoni, M; Pagès, P; Palka, H; Papadopoulou, T D; Papageorgiou, K; Pape, L; Parkes, C; Parodi, F; Passeri, A; Pegoraro, M; Peralta, L; Pernegger, H; Pernicka, Manfred; Perrotta, A; Petridou, C; Petrolini, A; Petrovykh, M; Phillips, H T; Piana, G; Pierre, F; Pimenta, M; Pindo, M; Plaszczynski, S; Podobrin, O; Pol, M E; Polok, G; Poropat, P; Pozdnyakov, V; Prest, M; Privitera, P; Pukhaeva, N; Pullia, Antonio; Radojicic, D; Ragazzi, S; Rahmani, H; Rames, J; Ratoff, P N; Read, A L; Reale, M; Rebecchi, P; Redaelli, N G; Regler, Meinhard; Reid, D; Renton, P B; Resvanis, L K; Richard, F; Richardson, J; Rídky, J; Rinaudo, G; Ripp, I; Romero, A; Roncagliolo, I; Ronchese, P; Roos, L; Rosenberg, E I; Rosso, E; Roudeau, Patrick; Rovelli, T; Rückstuhl, W; Ruhlmann-Kleider, V; Ruiz, A; Rybicki, K; Saarikko, H; Sacquin, Yu; Sadovskii, A; Sajot, G; Salt, J; Sánchez, J; Sannino, M; Schimmelpfennig, M; Schneider, H; Schwickerath, U; Schyns, M A E; Sciolla, G; Scuri, F; Seager, P; Sedykh, Yu; Segar, A M; Seitz, A; Sekulin, R L; Shellard, R C; Siccama, I; Siegrist, P; Simonetti, S; Simonetto, F; Sissakian, A N; Sitár, B; Skaali, T B; Smadja, G; Smirnov, N; Smirnova, O G; Smith, G R; Solovyanov, O; Sosnowski, R; Souza-Santos, D; Spassoff, Tz; Spiriti, E; Sponholz, P; Squarcia, S; Stanescu, C; Stapnes, Steinar; Stavitski, I; Stichelbaut, F; Stocchi, A; Strauss, J; Strub, R; Stugu, B; Szczekowski, M; Szeptycka, M; Tabarelli de Fatis, T; Tavernet, J P; Chikilev, O G; Tilquin, A; Timmermans, J; Tkatchev, L G; Todorov, T; Toet, D Z; Tomaradze, A G; Tomé, B; Tonazzo, A; Tortora, L; Tranströmer, G; Treille, D; Trischuk, W; Tristram, G; Trombini, A; Troncon, C; Tsirou, A L; Turluer, M L; Tyapkin, I A; Tyndel, M; Tzamarias, S; Überschär, B; Ullaland, O; Uvarov, V; Valenti, G; Vallazza, E; Van der Velde, C; van Apeldoorn, G W; van Dam, P; Van Doninck, W K; Van Eldik, J; Vassilopoulos, N; Vegni, G; Ventura, L; Venus, W A; Verbeure, F; Verlato, M; Vertogradov, L S; Vilanova, D; Vincent, P; Vitale, L; Vlasov, E; Vodopyanov, A S; Vrba, V; Wahlen, H; Walck, C; Weierstall, M; Weilhammer, Peter; Weiser, C; Wetherell, Alan M; Wicke, D; Wickens, J H; Wielers, M; Wilkinson, G R; Williams, W S C; Winter, M; Witek, M; Woschnagg, K; Yip, K; Yushchenko, O P; Zach, F; Zaitsev, A; Zalewska-Bak, A; Zalewski, Piotr; Zavrtanik, D; Zevgolatakos, E; Zimin, N I; Zito, M; Zontar, D; Zuberi, R; Zucchelli, G C; Zumerle, G; Charpentier, Ph; Gavillet, Ph

    1997-01-01

    Data are presented on the reaction \\epem~\\into~\\gamma + no other detected particle at center-of-mass energies, \\sqs = 89.48 GeV, 91.26 GeV and 93.08 GeV. The cross section for this reaction is related directly to the number of light neutrino generations which couple to the \\zz boson, and to several other phenomena such as excited neutrinos, the production of an invisible `X' particle, a possible magnetic moment of the tau neutrino, and neutral monojets. Based on the observed number of single photon events, the number of light neutrinos which couple to the \\zz is measured to be N_\

  15. Single-Photon Emission Computerized Tomography (SPECT in Neuropsychiatry: A Review

    Directory of Open Access Journals (Sweden)

    B. K. Puri

    1992-01-01

    Full Text Available Cranial single-photon emission computerized tomography (SPECT or SPET can now give regional cerebral blood flow images with a resolution approaching that of positron emission tomography (PET. In this paper, the use of high resolution SPECT neuroimaging in neuropsychiatric disorders, including Alzheimer's disease, multi-infarct dementia, Pick's disease, progressive supranuclear palsy, Korsakoff's psychosis, Creutzfeld-Jakob disease, Parkinson's disease, Huntington's disease, schizophrenia, mood disorders, obsessive–compulsive disorder, HIV infection and AIDS is reviewed. Finally, further potential research and clinical uses, based on ligand studies, are outlined.

  16. Single photon timing resolution and detection efficiency of the IRST silicon photo-multipliers

    International Nuclear Information System (INIS)

    Collazuol, G.; Ambrosi, G.; Boscardin, M.; Corsi, F.; Dalla Betta, G.F.; Del Guerra, A.; Dinu, N.; Galimberti, M.; Giulietti, D.; Gizzi, L.A.; Labate, L.; Llosa, G.; Marcatili, S.; Morsani, F.; Piemonte, C.; Pozza, A.; Zaccarelli, L.; Zorzi, N.

    2007-01-01

    Silicon photo-multipliers (SiPM) consist in matrices of tiny, passive quenched avalanche photo-diode cells connected in parallel via integrated resistors and operated in Geiger mode. Novel types of SiPM are being developed at FBK-IRST (Trento, Italy). Despite their classical shallow junction n-on-p structure the devices are unique in their enhanced photo-detection efficiency (PDE) for short-wavelengths and in their low level of dark rate and excess noise factor. After a summary of the extensive SiPM characterization we will focus on the study of PDE and the single photon timing resolution

  17. Painful spondylolysis or spondylolisthesis studied by radiography and single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Collier, B.D.; Johnson, R.P.; Carrera, G.F.

    1985-01-01

    Planar bone scintigraphy (PBS) and single-photon emission computed tomography (SPECT) were compared in 19 adults with radiographic evidence of spondylolysis and/or spondylolisthesis. SPECT was more sensitive than PBS when used to identify symptomatic patients and sites of painful defects in the pars interarticularis. In addition, SPECT allowed more accurate localization than PBS. In 6 patients, spondylolysis or spondylolisthesis was unrealted to low back pain, and SPECT images of the posterior neural arch were normal. The authors conclude that when spondylolysis or spondylolisthesis is the cause of low back pain, pars defects are frequently heralded by increased scintigraphic activity which is best detected and localized by SPECT

  18. Painful spondylolysis or spondylolisthesis studied by radiography and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Collier, B.D.; Johnson, R.P.; Carrera, G.F.; Meyer, G.A.; Schwab, J.P.; Flatley, T.J.; Isitman, A.T.; Hellman, R.S.; Zielonka, J.S.; Knobel, J.

    1985-01-01

    Planar bone scintigraphy (PBS) and single-photon emission computed tomography (SPECT) were compared in 19 adults with radiographic evidence of spondylolysis and/or spondylolisthesis. SPECT was more sensitive than PBS when used to identify symptomatic patients and sites of painful defects in the pars interarticularis. In addition, SPECT allowed more accurate localization than PBS. In 6 patients, spondylolysis or spondylolisthesis was unrealted to low back pain, and SPECT images of the posterior neural arch were normal. The authors conclude that when spondylolysis or spondylolisthesis is the cause of low back pain, pars defects are frequently heralded by increased scintigraphic activity which is best detected and localized by SPECT.

  19. Single-photon emission CT in the assessment of low back pain in young athletes

    International Nuclear Information System (INIS)

    Johnson, G.T.; Lagatutta, F.P.; Lazarus, M.L.; Faulkner, T.J.; Nolan, J.P.

    1991-01-01

    Fifty-two teenage and young adult athletes (ages 12-24 years) with low back pain (LBP) underwent routine lumbar radiography and bone scintigraphy including planar and single-photon CT and SPECT imaging. This paper illustrates the significant limitations of routine radiography and the importance of SPECT bone scintigraphy in evaluating young athletes with LBP and suspected spondylolysis; the increased sensitivity and specificity of SPECT compared to planar scintigraphy in the diagnosis of spondylolysis; and the potential utility of follow-up SPECT studies in evaluating success of therapy in athletes with initially positive diagnostic indicators for spondylolysis or impending spondylolysis

  20. High-fidelity teleportation of continuous-variable quantum States using delocalized single photons

    DEFF Research Database (Denmark)

    Andersen, Ulrik L; Ralph, Timothy C

    2013-01-01

    Traditional continuous-variable teleportation can only approach unit fidelity in the limit of an infinite (and unphysical) amount of squeezing. We describe a new method for continuous-variable teleportation that approaches unit fidelity with finite resources. The protocol is not based on squeezed...... states as in traditional teleportation but on an ensemble of single photon entangled states. We characterize the teleportation scheme with coherent states, mesoscopic superposition states, and two-mode squeezed states and we find several situations in which near-unity teleportation fidelity can...

  1. Simultaneous 99mTc and 123I dual-isotope brain striatal phantom single photon emission computed tomography: validation of 99mTc-TRODAT-1 and 123I-IBZM simultaneous dopamine system brain imaging.

    Science.gov (United States)

    Kao, Pan-Fu; Wey, Shiaw-Pyng; Yang, An-Shoei

    2009-11-01

    [2[[2-[[[3-(4-chlorophenyl)-8-methyl-8-azabicyclo[3,2,1]-oct-2-yl]-methyl](2-mercaptoethyl)-amino]ethyl]amino]ethanethiolato(3-)-N2,N2',S2,S2]oxo-[1R-exo-exo)])-[99mTc]-technetium (99mTc-TRODAT-1) and 123I-iodobenzamide (123I-IBZM) are radiotracers for brain dopamine pre- and postsynaptic neuron imaging. The purpose of this study was to evaluate imaging parameters and crossed energy interference using simultaneous single photon emission computed tomography (SPECT) 99mTc and 123I data acquisition. A five-compartment brain striatal phantom was filled with 99mTc and/or 123I radioactive solutions with different striatal-to-background ratios, ranging from 3:1 to 9:1. SPECT data were acquired with energy window settings of 15% for the centered window at 140 keV for 99mTc and a 10% asymmetric window at 159 keV for 123I. The experiments were carried out using either individual (99mTc or 123I only) or both radionuclides. The striatal-to-background ratios and energy crossed interference between 99mTc and 123I were calculated. The phantom SPECT images demonstrated that the energy crossed interferences from 123I to 99mTc, and vice versa, were 22 +/- 12.4% and 0.4 +/- 1.0%, respectively. A net interference of 7.1 +/- 4.0% for the counts in the 15% centered 99mTc window can be expected from 123I and a net interference of 1.6 +/- 3.3% for the counts in the 10% asymmetric 123I window was derived from 99mTc. The correlation of striatal-to-background ratios between single isotope and simultaneous dual-isotope was excellent (R2 = 0.99). The imaging parameters used in this simultaneous dualisotope SPECT imaging could be used in future clinical practice for imaging patients with movement disorders by using 99mTc-TRODAT-1 and 123I-IBZM. The striatal-to-background ratios were not affected by the crossed interference between 99mTc and 123I.

  2. Simultaneous 99mTC and 123I Dual-Isotope Brain Striatal Phantom Single Photon Emission Computed Tomography: Validation of 99mTC-Trodat-1 and 123I-IBZM Simultaneous Dopamine System Brain Imaging

    Directory of Open Access Journals (Sweden)

    Pan-Fu Kao

    2009-11-01

    Full Text Available [2[[2-[[[3-(4-chlorophenyl-8-methyl-8-azabicyclo[3,2,1]-oct-2-yl]-methyl](2-mercaptoethylamino]ethyl]amino]ethanethiolato(3--N2,N2′,S2,S2]oxo-[1R-exo-exo]-[99mTc]-technetium (99mTc-TRODAT-1 and 123I-iodobenzamide (123I-IBZM are radiotracers for brain dopamine preand postsynaptic neuron imaging. The purpose of this study was to evaluate imaging parameters and crossed energy interference using simultaneous single photon emission computed tomography (SPECT 99mTc and 123I data acquisition. A five-compartment brain striatal phantom was filled with 99mTc and/or 123I radioactive solutions with different striatal-to-background ratios, ranging from 3:1 to 9:1. SPECT data were acquired with energy window settings of 15% for the centered window at 140 keV for 99mTc and a 10% asymmetric window at 159 keV for 123I. The experiments were carried out using either individual (99mTc or 123I only or both radionuclides. The striatal-to-background ratios and energy crossed interference between 99mTc and 123I were calculated. The phantom SPECT images demonstrated that the energy crossed interferences from 123I to 99mTc, and vice versa, were 22 ± 12.4% and 0.4 ± 1.0%, respectively. A net interference of 7.1 ± 4.0% for the counts in the 15% centered 99mTc window can be expected from 123I and a net interference of 1.6 ± 3.3% for the counts in the 10% asymmetric 123I window was derived from 99mTc. The correlation of striatal-to-background ratios between single isotope and simultaneous dual-isotope was excellent (R2 = 0.99. The imaging parameters used in this simultaneous dual-isotope SPECT imaging could be used in future clinical practice for imaging patients with movement disorders by using 99mTc-TRODAT-1 and 123I-IBZM. The striatal-to-background ratios were not affected by the crossed interference between 99mTc and 123I.

  3. Scanning, Multibeam, Single Photon Lidars for Rapid, Large Scale, High Resolution, Topographic and Bathymetric Mapping

    Directory of Open Access Journals (Sweden)

    John J. Degnan

    2016-11-01

    Full Text Available Several scanning, single photon sensitive, 3D imaging lidars are herein described that operate at aircraft above ground levels (AGLs between 1 and 11 km, and speeds in excess of 200 knots. With 100 beamlets and laser fire rates up to 60 kHz, we, at the Sigma Space Corporation (Lanham, MD, USA, have interrogated up to 6 million ground pixels per second, all of which can record multiple returns from volumetric scatterers such as tree canopies. High range resolution has been achieved through the use of subnanosecond laser pulsewidths, detectors and timing receivers. The systems are presently being deployed on a variety of aircraft to demonstrate their utility in multiple applications including large scale surveying, bathymetry, forestry, etc. Efficient noise filters, suitable for near realtime imaging, have been shown to effectively eliminate the solar background during daytime operations. Geolocation elevation errors measured to date are at the subdecimeter level. Key differences between our Single Photon Lidars, and competing Geiger Mode lidars are also discussed.

  4. Performance and limitations of high granularity single photon processing X-ray imaging detectors

    CERN Document Server

    Tlustos, L

    2005-01-01

    Progress in CMOS technology and in fine pitch bump bonding has made possible the development of single photon counting detectors for X-ray imaging with pixel pitches on the order of 50 µm giving a spatial resolution which is comparable to conventional CCD and flat panel detectors. This thesis studies the interaction of X-ray photons in the energy range of 5 keV to 70 keV with various sensor materials as well as the response of the Medipix2 readout system to both monochromatic and wide spectrum X-ray sources. Single photon processing offers the potential for spectroscopic imaging. However, this thesis demonstrates using simulations and measurements that the charge deposition and collection within the semiconductor sensor impose fundamental limits on the achievable energy resolution. In particular the discussion of charge during collection in the sensor and the generation of fluorescence photons in heavier sensor materials contribute to the appearance of a low energy tail on the detected spectrum of an incomin...

  5. Strong coupling of a single photon to a superconducting qubit using circuit quantum electrodynamics.

    Science.gov (United States)

    Wallraff, A; Schuster, D I; Blais, A; Frunzio, L; Huang, R- S; Majer, J; Kumar, S; Girvin, S M; Schoelkopf, R J

    2004-09-09

    The interaction of matter and light is one of the fundamental processes occurring in nature, and its most elementary form is realized when a single atom interacts with a single photon. Reaching this regime has been a major focus of research in atomic physics and quantum optics for several decades and has generated the field of cavity quantum electrodynamics. Here we perform an experiment in which a superconducting two-level system, playing the role of an artificial atom, is coupled to an on-chip cavity consisting of a superconducting transmission line resonator. We show that the strong coupling regime can be attained in a solid-state system, and we experimentally observe the coherent interaction of a superconducting two-level system with a single microwave photon. The concept of circuit quantum electrodynamics opens many new possibilities for studying the strong interaction of light and matter. This system can also be exploited for quantum information processing and quantum communication and may lead to new approaches for single photon generation and detection.

  6. Measurement system of correlation functions of microwave single photon source in real time

    Science.gov (United States)

    Korenkov, A.; Dmitriev, A.; Astafiev, O.

    2018-02-01

    Several quantum setups, such as quantum key distribution networks[1] and quantum simulators (e.g. boson sampling), by their design rely on single photon sources (SPSs). These quantum setups were demonstrated to operate in optical frequency domain. However, following the steady advances in circuit quantum electrodynamics, a proposal has been made recently[2] to demonstrate boson sampling with microwave photons. This in turn requires the development of reliable microwave SPS. It's one of the most important characteristics are the first-order and the second-order correlation functions g1 and g2. The measurement technique of g1 and g2 is significantly different from that in the optical domain [3],[4] because of the current unavailability of microwave single-photon detectors. In particular, due to high levels of noise present in the system a substantial amount of statistics in needed to be acquired. This work presents a platform for measurement of g1 and g2 that processes the incoming data in real time, maximizing the efficiency of data acquisition. The use of field-programmable gate array (FPGA) electronics, common in similar experiments[3] but complex in programming, is avoided; instead, the calculations are performed on a standard desktop computer. The platform is used to perform the measurements of the first-order and the second-order correlation functions of the microwave SPS.

  7. 32-channel time-correlated-single-photon-counting system for high-throughput lifetime imaging.

    Science.gov (United States)

    Peronio, P; Labanca, I; Acconcia, G; Ruggeri, A; Lavdas, A A; Hicks, A A; Pramstaller, P P; Ghioni, M; Rech, I

    2017-08-01

    Time-Correlated Single Photon Counting (TCSPC) is a very efficient technique for measuring weak and fast optical signals, but it is mainly limited by the relatively "long" measurement time. Multichannel systems have been developed in recent years aiming to overcome this limitation by managing several detectors or TCSPC devices in parallel. Nevertheless, if we look at state-of-the-art systems, there is still a strong trade-off between the parallelism level and performance: the higher the number of channels, the poorer the performance. In 2013, we presented a complete and compact 32 × 1 TCSPC system, composed of an array of 32 single-photon avalanche diodes connected to 32 time-to-amplitude converters, which showed that it was possible to overcome the existing trade-off. In this paper, we present an evolution of the previous work that is conceived for high-throughput fluorescence lifetime imaging microscopy. This application can be addressed by the new system thanks to a centralized logic, fast data management and an interface to a microscope. The new conceived hardware structure is presented, as well as the firmware developed to manage the operation of the module. Finally, preliminary results, obtained from the practical application of the technology, are shown to validate the developed system.

  8. Periodically modulated single-photon transport in one-dimensional waveguide

    Science.gov (United States)

    Li, Xingmin; Wei, L. F.

    2018-03-01

    Single-photon transport along a one-dimension waveguide interacting with a quantum system (e.g., two-level atom) is a very useful and meaningful simplified model of the waveguide-based optical quantum devices. Thus, how to modulate the transport of the photons in the waveguide structures by adjusting certain external parameters should be particularly important. In this paper, we discuss how such a modulation could be implemented by periodically driving the energy splitting of the interacting atom and the atom-photon coupling strength. By generalizing the well developed time-independent full quantum mechanical theory in real space to the time-dependent one, we show that various sideband-transmission phenomena could be observed. This means that, with these modulations the photon has certain probabilities to transmit through the scattering atom in the other energy sidebands. Inversely, by controlling the sideband transmission the periodic modulations of the single photon waveguide devices could be designed for the future optical quantum information processing applications.

  9. Optimizing the photon selection of the CMS Single-Photon search for Supersymmetry using multivariate analyses

    CERN Document Server

    Lange, Johannes

    2014-01-01

    The purpose of this thesis is to improve the photon selection of the CMS SinglePhoton search for Supersymmetry by using multivariate analyses.The Single-Photon search aims to find Supersymmetry (SUSY) in data taken by theCompact Muon Solenoid (CMS) detector at the Large Hadron Collider located atthe research center CERN. SUSY is an extension of the standard model of particlephysics. The search is designed for a general gauge mediation scenario, which describes the gauge mediated SUSY breaking. The analysis uses final states with jets,at least one photon and missing transverse energy. A data-driven prediction of themultijet background is performed for the analysis. For this purpose, photon candidates have to be classified into two selections.In this thesis the usage of multivariate analyses for the photon candidate classification is studied. The methods used are Fisher Discriminant, Boosted Decision Treesand Artificial Neural Networks. Their performance is evaluated with respect to different aspects impor...

  10. 32-channel time-correlated-single-photon-counting system for high-throughput lifetime imaging

    Science.gov (United States)

    Peronio, P.; Labanca, I.; Acconcia, G.; Ruggeri, A.; Lavdas, A. A.; Hicks, A. A.; Pramstaller, P. P.; Ghioni, M.; Rech, I.

    2017-08-01

    Time-Correlated Single Photon Counting (TCSPC) is a very efficient technique for measuring weak and fast optical signals, but it is mainly limited by the relatively "long" measurement time. Multichannel systems have been developed in recent years aiming to overcome this limitation by managing several detectors or TCSPC devices in parallel. Nevertheless, if we look at state-of-the-art systems, there is still a strong trade-off between the parallelism level and performance: the higher the number of channels, the poorer the performance. In 2013, we presented a complete and compact 32 × 1 TCSPC system, composed of an array of 32 single-photon avalanche diodes connected to 32 time-to-amplitude converters, which showed that it was possible to overcome the existing trade-off. In this paper, we present an evolution of the previous work that is conceived for high-throughput fluorescence lifetime imaging microscopy. This application can be addressed by the new system thanks to a centralized logic, fast data management and an interface to a microscope. The new conceived hardware structure is presented, as well as the firmware developed to manage the operation of the module. Finally, preliminary results, obtained from the practical application of the technology, are shown to validate the developed system.

  11. On-chip single photon filtering and multiplexing in hybrid quantum photonic circuits.

    Science.gov (United States)

    Elshaari, Ali W; Zadeh, Iman Esmaeil; Fognini, Andreas; Reimer, Michael E; Dalacu, Dan; Poole, Philip J; Zwiller, Val; Jöns, Klaus D

    2017-08-30

    Quantum light plays a pivotal role in modern science and future photonic applications. Since the advent of integrated quantum nanophotonics different material platforms based on III-V nanostructures-, colour centers-, and nonlinear waveguides as on-chip light sources have been investigated. Each platform has unique advantages and limitations; however, all implementations face major challenges with filtering of individual quantum states, scalable integration, deterministic multiplexing of selected quantum emitters, and on-chip excitation suppression. Here we overcome all of these challenges with a hybrid and scalable approach, where single III-V quantum emitters are positioned and deterministically integrated in a complementary metal-oxide-semiconductor-compatible photonic circuit. We demonstrate reconfigurable on-chip single-photon filtering and wavelength division multiplexing with a foot print one million times smaller than similar table-top approaches, while offering excitation suppression of more than 95 dB and efficient routing of single photons over a bandwidth of 40 nm. Our work marks an important step to harvest quantum optical technologies' full potential.Combining different integration platforms on the same chip is currently one of the main challenges for quantum technologies. Here, Elshaari et al. show III-V Quantum Dots embedded in nanowires operating in a CMOS compatible circuit, with controlled on-chip filtering and tunable routing.

  12. Cooperative single-photon subradiant states in a three-dimensional atomic array

    Energy Technology Data Exchange (ETDEWEB)

    Jen, H.H., E-mail: sappyjen@gmail.com

    2016-11-15

    We propose a complete superradiant and subradiant states that can be manipulated and prepared in a three-dimensional atomic array. These subradiant states can be realized by absorbing a single photon and imprinting the spatially-dependent phases on the atomic system. We find that the collective decay rates and associated cooperative Lamb shifts are highly dependent on the phases we manage to imprint, and the subradiant state of long lifetime can be found for various lattice spacings and atom numbers. We also investigate both optically thin and thick atomic arrays, which can serve for systematic studies of super- and sub-radiance. Our proposal offers an alternative scheme for quantum memory of light in a three-dimensional array of two-level atoms, which is applicable and potentially advantageous in quantum information processing. - Highlights: • Cooperative single-photon subradiant states in a three-dimensional atomic array. • Subradiant state manipulation via spatially-increasing phase imprinting. • Quantum storage of light in the subradiant state in two-level atoms.

  13. A superconducting microcalorimeter for low-flux detection of near-infrared single photons

    International Nuclear Information System (INIS)

    Dreyling-Eschweiler, Jan

    2014-07-01

    This thesis covers the development and the characterization of a single photon detector based on a superconducting microcalorimeter. The detector development is motivated by the Any Light Particle Search II (ALPS II) experiment at DESY in Hamburg, which searches for weakly interacting sub-eV particles (WISPs). Therefore, a detection of low-fluxes of 1064 nm light is required. The work is divided in three analyses: the characterization of a milli-kelvin (mK) cryostat, the characterization of superconducting sensors for single photon detection, and the determination of dark count rates concerning 1064 nm signals. Firstly, an adiabatic demagnetization refrigerator (ADR) is characterized, which allows to reach mK-temperatures. During commissioning, the ADR cryostat is optimized and prepared to stably cool superconducting sensors at 80 mK±25 μK. It is found that sensors can be continuously operated for ∝20 h before recharging the system in -4 s -1 . By operating a fiber-coupled TES, it is found that the dark count rate for 1064 nm signals is dominated by pile-up events of near-infrared thermal photons coming through the fiber from the warm environment. Considering a detection efficiency of ∝18 %, a dark count rate of 8.6 . 10 -3 s -1 is determined for 1064 nm ALPS photons.Concerning ALPS II, this results in a sensitivity gain compared to the ALPS I detector. Furthermore, this thesis is the starting point of TES detector development in Hamburg, Germany.

  14. An all-silicon single-photon source by unconventional photon blockade.

    Science.gov (United States)

    Flayac, Hugo; Gerace, Dario; Savona, Vincenzo

    2015-06-10

    The lack of suitable quantum emitters in silicon and silicon-based materials has prevented the realization of room temperature, compact, stable, and integrated sources of single photons in a scalable on-chip architecture, so far. Current approaches rely on exploiting the enhanced optical nonlinearity of silicon through light confinement or slow-light propagation, and are based on parametric processes that typically require substantial input energy and spatial footprint to reach a reasonable output yield. Here we propose an alternative all-silicon device that employs a different paradigm, namely the interplay between quantum interference and the third-order intrinsic nonlinearity in a system of two coupled optical cavities. This unconventional photon blockade allows to produce antibunched radiation at extremely low input powers. We demonstrate a reliable protocol to operate this mechanism under pulsed optical excitation, as required for device applications, thus implementing a true single-photon source. We finally propose a state-of-art implementation in a standard silicon-based photonic crystal integrated circuit that outperforms existing parametric devices either in input power or footprint area.

  15. Single photon image from PET with insertable collimator for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Jung, Jooyoung; Suh, Tae Suk; Hong, Key Jo

    2014-01-01

    Boron neutron capture therapy (BNCT) is a radiation therapy technique for treating deep-seated brain tumors by irradiation with a thermal neutron in which boron-labelled low molecular weight compounds. Once completed, a single photon emission computed tomography (SPECT) scan is conducted to investigate for the region of therapy using an isotope exclusive to SPECT. In the case of an existing PET/SPECT combination system, at least two types of isotopes should be used for each scan with their purposes. Recently, researchers examined the effects of PET/SPECT dual modality on animal imaging systems. They reported that the PET/SPECT combination system was effective for simultaneous achievement of a single event and coincidence. The aim of our proposed system is to confirm the feasibility of extraction of two types of images from one PET module with an insertable collimator for brain tumor treatment during the BNCT. We attempted to acquire the PET and SPECT images simultaneously using only PET without an additional isotope. Single photon images were acquired using an insertable collimator on a PET detector

  16. Multi-photon creation and single-photon annihilation of electron-positron pairs

    International Nuclear Information System (INIS)

    Hu, Huayu

    2011-01-01

    In this thesis we study multi-photon e + e - pair production in a trident process, and singlephoton e + e - pair annihilation in a triple interaction. The pair production is considered in the collision of a relativistic electron with a strong laser beam, and calculated within the theory of laser-dressed quantum electrodynamics. A regularization method is developed systematically for the resonance problem arising in the multi-photon process. Total production rates, positron spectra, and relative contributions of different reaction channels are obtained in various interaction regimes. Our calculation shows good agreement with existing experimental data from SLAC, and adds further insights into the experimental findings. Besides, we study the process in a manifestly nonperturbative domain, whose accessibility to future all-optical experiments based on laser acceleration is shown. In the single-photon e + e - pair annihilation, the recoil momentum is absorbed by a spectator particle. Various kinematic configurations of the three incoming particles are examined. Under certain conditions, the emitted photon exhibits distinct angular and polarization distributions which could facilitate the detection of the process. Considering an equilibrium relativistic e + e - plasma, it is found that the single-photon process becomes the dominant annihilation channel for plasma temperatures above 3 MeV. Multi-particle correlation effects are therefore essential for the e + e - dynamics at very high density. (orig.)

  17. Design and Characterization of 64K Pixels Chips Working in Single Photon Processing Mode

    CERN Document Server

    Llopart Cudie, Xavier; Campbell, M

    2007-01-01

    Progress in CMOS technology and in fine pitch bump bonding has made possible the development of high granularity single photon counting detectors for X-ray imaging. This thesis studies the design and characterization of three pulse processing chips with 65536 square pixels of 55 µm x 55 µm designed in a commercial 0.25 µm 6-metal CMOS technology. The 3 chips share the same architecture and dimensions and are named Medipix2, Mpix2MXR20 and Timepix. The Medipix2 chip is a pixel detector readout chip consisting of 256 x 256 identical elements, each working in single photon counting mode for positive or negative input charge signals. The preamplifier feedback provides compensation for detector leakage current on a pixel by pixel basis. Two identical pulse height discriminators are used to define an energy window. Every event falling inside the energy window is counted with a 13 bit pseudo-random counter. The counter logic, based in a shift register, also behaves as the input/output register for the pixel. Each...

  18. Memory effect in gated single-photon avalanche diodes: a limiting noise contribution similar to afterpulsing

    Science.gov (United States)

    Contini, D.; Dalla Mora, A.; Di Sieno, L.; Cubeddu, R.; Tosi, A.; Boso, G.; Pifferi, A.

    2013-03-01

    In recent years, emerging applications, such as diffuse optical imaging and spectroscopy (e.g., functional brain imaging and optical mammography), in which a wide dynamic range is crucial, have turned the interest towards Single-Photon Avalanche Diode (SPAD). In these fields, the use of a fast-gated SPAD has proven to be a successful technique to increase the measurement sensitivity of different orders of magnitude. However, an unknown background noise has been observed at high illumination during the gate-OFF time, thus setting a limit to the maximum increase of the dynamic range. In this paper we describe this noise in thin-junction silicon single-photon avalanche diode when a large amount of photons reaches the gated detector during the OFF time preceding the enabling time. This memory effect increases the background noise with respect to primary dark count rate similarly to a classical afterpulsing process, but differently it is not related to a previous avalanche ignition in the detector. We discovered that memory effect increases linearly with the power of light impinging on the detector and it has an exponential trend with time constants far different from those of afterpulsing and independently of the bias voltage applied to the junction. For these reasons, the memory effect is not due to the same trapping states of afterpulsing and must be described as a different process.

  19. Single photon emitters in boron nitride: More than a supplementary material

    Science.gov (United States)

    Koperski, M.; Nogajewski, K.; Potemski, M.

    2018-03-01

    We present comprehensive optical studies of recently discovered single photon sources in boron nitride, which appear in form of narrow lines emitting centres. Here, we aim to compactly characterise their basic optical properties, including the demonstration of several novel findings, in order to inspire discussion about their origin and utility. Initial inspection reveals the presence of narrow emission lines in boron nitride powder and exfoliated flakes of hexagonal boron nitride deposited on Si/SiO2 substrates. Generally rather stable, the boron nitride emitters constitute a good quality visible light source. However, as briefly discussed, certain specimens reveal a peculiar type of blinking effects, which are likely related to existence of meta-stable electronic states. More advanced characterisation of representative stable emitting centres uncovers a strong dependence of the emission intensity on the energy and polarisation of excitation. On this basis, we speculate that rather strict excitation selectivity is an important factor determining the character of the emission spectra, which allows the observation of single and well-isolated emitters. Finally, we investigate the properties of the emitting centres in varying external conditions. Quite surprisingly, it is found that the application of a magnetic field introduces no change in the emission spectra of boron nitride emitters. Further analysis of the impact of temperature on the emission spectra and the features seen in second-order correlation functions is used to provide an assessment of the potential functionality of boron nitride emitters as single photon sources capable of room temperature operation.

  20. Multi-photon creation and single-photon annihilation of electron-positron pairs

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Huayu

    2011-04-27

    In this thesis we study multi-photon e{sup +}e{sup -} pair production in a trident process, and singlephoton e{sup +}e{sup -} pair annihilation in a triple interaction. The pair production is considered in the collision of a relativistic electron with a strong laser beam, and calculated within the theory of laser-dressed quantum electrodynamics. A regularization method is developed systematically for the resonance problem arising in the multi-photon process. Total production rates, positron spectra, and relative contributions of different reaction channels are obtained in various interaction regimes. Our calculation shows good agreement with existing experimental data from SLAC, and adds further insights into the experimental findings. Besides, we study the process in a manifestly nonperturbative domain, whose accessibility to future all-optical experiments based on laser acceleration is shown. In the single-photon e{sup +}e{sup -} pair annihilation, the recoil momentum is absorbed by a spectator particle. Various kinematic configurations of the three incoming particles are examined. Under certain conditions, the emitted photon exhibits distinct angular and polarization distributions which could facilitate the detection of the process. Considering an equilibrium relativistic e{sup +}e{sup -} plasma, it is found that the single-photon process becomes the dominant annihilation channel for plasma temperatures above 3 MeV. Multi-particle correlation effects are therefore essential for the e{sup +}e{sup -} dynamics at very high density. (orig.)

  1. Analysis of single photon detection in avalanche photodetectors with multi-gain-stage multiplication region.

    Science.gov (United States)

    Hosseinzadeh, Amir; Zavvari, Mahdi

    2017-02-20

    We report the design and analysis of a single photon avalanche detector (SPAD) with cascaded multiplication stages with asymmetric gain series for near-IR applications. The asymmetric gain profile allows us to selectively enhance the ionization coefficient for injected electrons and suppress the hole-initiated ionization by repetition of high and low field layers. The low field layer acts as a carrier relaxation region, which inhibits avalanche feedback between stages; hence, it is expected to have a lower dark count rate (DCR). The gain stage consists of three distinct layers with different electric fields, which can be adjusted by geometrical and mole fraction design. In this paper we study the effect of these layers' field and thickness on the single photon quantum efficiency (SPQE) and DCR of the proposed SPAD. Our results show that the high-field layer can better influence the performance of the detector rather than the others. In comparison with a conventional SPAD with a uniform multiplication region, our proposed structure shows lower DCR for a same SPQE.

  2. High-efficiency integrated readout circuit for single photon avalanche diode arrays in fluorescence lifetime imaging

    Science.gov (United States)

    Acconcia, G.; Cominelli, A.; Rech, I.; Ghioni, M.

    2016-11-01

    In recent years, lifetime measurements by means of the Time Correlated Single Photon Counting (TCSPC) technique have led to a significant breakthrough in medical and biological fields. Unfortunately, the many advantages of TCSPC-based approaches come along with the major drawback of a relatively long acquisition time. The exploitation of multiple channels in parallel could in principle mitigate this issue, and at the same time it opens the way to a multi-parameter analysis of the optical signals, e.g., as a function of wavelength or spatial coordinates. The TCSPC multichannel solutions proposed so far, though, suffer from a tradeoff between number of channels and performance, and the overall measurement speed has not been increased according to the number of channels, thus reducing the advantages of having a multichannel system. In this paper, we present a novel readout architecture for bi-dimensional, high-density Single Photon Avalanche Diode (SPAD) arrays, specifically designed to maximize the throughput of the whole system and able to guarantee an efficient use of resources. The core of the system is a routing logic that can provide a dynamic connection between a large number of SPAD detectors and a much lower number of high-performance acquisition channels. A key feature of our smart router is its ability to guarantee high efficiency under any operating condition.

  3. DE-BLURRING SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY IMAGES USING WAVELET DECOMPOSITION

    Directory of Open Access Journals (Sweden)

    Neethu M. Sasi

    2016-02-01

    Full Text Available Single photon emission computed tomography imaging is a popular nuclear medicine imaging technique which generates images by detecting radiations emitted by radioactive isotopes injected in the human body. Scattering of these emitted radiations introduces blur in this type of images. This paper proposes an image processing technique to enhance cardiac single photon emission computed tomography images by reducing the blur in the image. The algorithm works in two main stages. In the first stage a maximum likelihood estimate of the point spread function and the true image is obtained. In the second stage Lucy Richardson algorithm is applied on the selected wavelet coefficients of the true image estimate. The significant contribution of this paper is that processing of images is done in the wavelet domain. Pre-filtering is also done as a sub stage to avoid unwanted ringing effects. Real cardiac images are used for the quantitative and qualitative evaluations of the algorithm. Blur metric, peak signal to noise ratio and Tenengrad criterion are used as quantitative measures. Comparison against other existing de-blurring algorithms is also done. The simulation results indicate that the proposed method effectively reduces blur present in the image.

  4. Source of single photons and interferometry with one photon. From the Young's slit experiment to the delayed choice

    International Nuclear Information System (INIS)

    Jacques, V.

    2007-11-01

    This manuscript is divided in two independent parts. In the first part, we study the wave-particle duality for a single photon emitted by the triggered photoluminescence of a single NV color center in a diamond nano-crystal. We first present the realization of a single-photon interference experiment using a Fresnel's bi-prism, in a scheme equivalent to the standard Young's double-slit textbook experiment. We then discuss the complementarity between interference and which-path information in this two-path interferometer. We finally describe the experimental realization of Wheeler's delayed-choice Gedanken experiment, which is a fascinating and subtle illustration of wave-particle duality. The second part of the manuscript is devoted to the efficiency improvement of single-photon sources. We first describe the implementation of a new single-photon source based on the photoluminescence of a single nickel-related defect center in diamond. The photophysical properties of such defect make this single-photon source well adapted to open-air quantum cryptography. We finally demonstrate an original method that leads to an improvement of single-molecule photo stability at room temperature. (author)

  5. [123I]Iodobenzamide binding to the rat dopamine D2 receptor in competition with haloperidol and endogenous dopamine - an in vivo imaging study with a dedicated small animal SPECT

    International Nuclear Information System (INIS)

    Nikolaus, Susanne; Larisch, Rolf; Wirrwar, Andreas; Jamdjeu-Noune, Marlyse; Antke, Christina; Beu, Markus; Mueller, Hans-Wilhelm; Schramm, Nils

    2005-01-01

    This study assessed [ 123 I]iodobenzamide binding to the rat dopamine D 2 receptor in competition with haloperidol and endogenous dopamine using a high-resolution small animal SPECT. Subsequent to baseline quantifications of D 2 receptor binding, imaging studies were performed on the same animals after pre-treatment with haloperidol and methylphenidate, which block D 2 receptors and dopamine transporters, respectively. Striatal baseline equilibrium ratios (V 3 '' ) of [ 123 I]iodobenzamide binding were 1.42±0.31 (mean±SD). After pre-treatment with haloperidol and methylphenidate, V 3 '' values decreased to 0.54±0.46 (p 123 I]iodobenzamide binding induced by pre-treatment with haloperidol reflects D 2 receptor blockade, whereas the decrease in receptor binding induced by pre-treatment with methylphenidate can be interpreted in terms of competition between [ 123 I]IBZM and endogenous dopamine. Findings show that multiple in vivo measurements of [ 123 I]iodobenzamide binding to D 2 receptors in competition with exogenous and endogenous ligands are feasible in the same animal. This may be of future relevance for the in vivo evaluation of novel radioligands as well as for studying the interrelations between pre- and/or postsynaptic radioligand binding and different levels of endogenous dopamine. (orig.)

  6. Uptake in melanoma cells of N-(2-diethylaminoethyl)-2-iodobenzamide (BZA2), an imaging agent for melanoma staging: relation to pigmentation.

    Science.gov (United States)

    Mansard, Sandrine; Papon, Janine; Moreau, Marie-France; Miot-Noirault, Elisabeth; Labarre, Pierre; Bayle, Martine; Veyre, Annie; Madelmont, Jean-Claude; Moins, Nicole

    2005-07-01

    N-(2-diethylaminoethyl)-2-iodobenzamide (BZA(2)) has been singled out as the most efficacious melanoma scintigraphy imaging agent. Our work was designed to assess the mechanisms of the specific affinity of the radioiodinated iodobenzamide for melanoma tissue. We studied the cellular uptake and retention of [(125)I]-BZA(2) on various cell lines. In vitro, cellular [(125)I]-BZA(2) uptake was related to the pigmentation status of the cells: higher in pigmented melanoma cell lines (M4 Beu, IPC 227, B 16) than in a nonpigmented one (M3 Dau) and nonmelanoma cell lines (MCF 7 and L 929). Two mechanisms were assessed: binding of the tracer to melanin or to sigma receptors of melanoma cells. First, the uptake of [(125)I]-BZA(2) after melanogenesis stimulation by alpha-melanocyte-stimulating hormone and l-tyrosine increased in the B 16 melanoma cell line both in vitro and in vivo according to melanin concentration. Moreover, the binding of [(125)I]-BZA(2) to synthetic melanin was dependent on melanin concentration and could be saturated. Second, no competition was evidenced on M4 Beu cells between [(125)I]-BZA(2) and haloperidol, a sigma ligand, at concentrations < or =10(-6) M. We show that the specificity and sensibility of BZA(2) as a melanoma scintigraphic imaging agent are mostly due to interactions with melanic pigments.

  7. Single-photon emission correlated to double-electron capture by bare ions: background processes

    Science.gov (United States)

    Elkafrawy, T.; Warczak, A.; Simon, A.; Tanis, J. A.

    2013-09-01

    Radiative single- and double-electron capture are one-step processes where a single target electron or two target electrons, respectively, are captured to a bound state of a highly charged projectile with the simultaneous emission of a single photon. In ion-atom collisions, several background processes are likely to contribute to these processes and may interfere with the measured x-rays due to radiative single and double capture. In this study, possible contributions from radiative electron capture to the continuum, secondary electron bremsstrahlung, the two-step process of independent double radiative electron capture, as well as radiative- combined with nonradiative-electron capture are taken into account based on our analysis of the data for 2.21 MeV u-1 F9+ ions colliding with a thin carbon foil.

  8. Single-photon emission associated with double electron capture in F9 ++C collisions

    Science.gov (United States)

    Elkafrawy, T.; Simon, A.; Tanis, J. A.; Warczak, A.

    2016-10-01

    Radiative double electron capture (RDEC), the one-step process occurring in ion-atom collisions, has been investigated for bare fluorine ions colliding with carbon. RDEC is completed when two target electrons are captured to a bound state of a projectile simultaneously with the emission of a single photon. This work is a follow-up to our earlier measurement of RDEC for bare oxygen projectiles, thus providing a recipient system free of electron-related Coulomb fields in both cases and allowing for the comparison between the two collision systems as well as with available theoretical studies. The most significant mechanisms of x-ray emission that may contribute to the RDEC energy region as background processes are also addressed.

  9. Comparative study of afterpulsing behavior and models in single photon counting avalanche photo diode detectors.

    Science.gov (United States)

    Ziarkash, Abdul Waris; Joshi, Siddarth Koduru; Stipčević, Mario; Ursin, Rupert

    2018-03-22

    Single-photon avalanche diode (SPAD) detectors, have a great importance in fields like quantum key distribution, laser ranging, florescence microscopy, etc. Afterpulsing is a non-ideal behavior of SPADs that adversely affects any application that measures the number or timing of detection events. Several studies based on a few individual detectors, derived distinct mathematical models from semiconductor physics perspectives. With a consistent testing procedure and statistically large data sets, we show that different individual detectors - even if identical in type, make, brand, etc. - behave according to fundamentally different mathematical models. Thus, every detector must be characterized individually and it is wrong to draw universal conclusions about the physical meaning behind these models. We also report the presence of high-order afterpulses that are not accounted for in any of the standard models.

  10. Non-Markovian dynamics of a qubit due to single-photon scattering in a waveguide

    Science.gov (United States)

    Fang, Yao-Lung L.; Ciccarello, Francesco; Baranger, Harold U.

    2018-04-01

    We investigate the open dynamics of a qubit due to scattering of a single photon in an infinite or semi-infinite waveguide. Through an exact solution of the time-dependent multi-photon scattering problem, we find the qubit's dynamical map. Tools of open quantum systems theory allow us then to show the general features of this map, find the corresponding non-Linbladian master equation, and assess in a rigorous way its non-Markovian nature. The qubit dynamics has distinctive features that, in particular, do not occur in emission processes. Two fundamental sources of non-Markovianity are present: the finite width of the photon wavepacket and the time delay for propagation between the qubit and the end of the semi-infinite waveguide.

  11. Depression following intracerebral hemorrhage and the evaluation of cerebral blood flow by single photon emission tomography

    International Nuclear Information System (INIS)

    Masada, Tetsuya; Makabe, Tetsuo; Kunishio, Katsuzo; Matsumoto, Akira

    2007-01-01

    The authors studied patients who presented depression and apathy following intracerebral hemorrhage (ICH). Twelve patients who were admitted in our hospital were divided into two groups according to the presence of post-stroke depression (PSD). Five patients with PSD are in group A, and another seven patients without PSD are in group B. Zung-self depression scale (SDS) and apathy scale were used for screening of depression and apathy. PSD was recognized in 5 (42%) of patients following ICH. Single photon emission tomography (SPECT) suggested the reduction of cerebral blood flow (CBF) in the frontal lobe in all patients of the group A (100%), whereas only 29% of patients of the group B. The reduction of CBF in the frontal lobe might be involved in the mechanism of depression following ICH in subacute stage. (author)

  12. A study on single photon production at radicals=54. 0-61. 4 GeV

    Energy Technology Data Exchange (ETDEWEB)

    Abe, K. (Tohoku Univ., Sendai (Japan)); Amako, K.; Arai, Y.; Fukawa, M.; Fukushima, Y.; Haidt, D.; Ishihara, N.; Kamitani, T.; Kanzaki, J.; Kondo, T.; Matsui, T.; Odaka, S.; Ogawa, K.; Ohama, T.; Sakamoto, H.; Sakuda, M.; Shirai, J.; Sumiyoshi, T.; Takasaki, F.; Tsuboyama, T.; Uehara, S.; Unno, Y.; Watase, Y.; Yamada, Y. (National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan)); Asano, Y.; Koseki, T.; Mori, S.; Sakano, M.; Shirakata, S.; Takada, Y.; Yonezawa, Y. (Tsukuba Univ., Sakura, Ibaraki (Japan)); Chiba, M.; Fukui, T.; Hirose, T.; Minami, M.; Narita, Y.; Oyama, T.; Saito, H.; Utsumi, M.; Wakai, M.; Watanabe, T.; Yabuki, F.; Yamagata, T. (Tokyo Metropolitan Univ. (Japan)); Chiba, Y.; Endo, I.; Hayashibara, I.; Ohsugi, T.; Taketani, A.; Tanaka, R.; Terunuma, N. (Hiroshima Univ. (Japan)); Daigo, M. (Wakayama Medical Coll. (Japan)); Emura, T. (Tokyo Univ. of Agriculture and Tech., Koganei (Japan). Faculty of Engineering); Haba, J.; Kanematsu, N.; Nagashima, Y.; Osabe,; VENUS Collaboration

    1989-12-07

    A study of single photon events, produced in association with light neutrinos or other weakly interacting neutral particles in e{sup +}e{sup -} collisions, has been performed at radicals=54.0-61.4 GeV with the VENUS detector at TRISTAN. No anomalous signal has been observed in a data sample corresponding to an integrated luminosity of 28.2 pb{sup -1}. This result indicates that the upper limit on the number of light neutrinos, N{sub nu}, is 11 (15) at a 90 (95)% confidence level. Combining this with published results from other e{sup +}e{sup -} experiments, the number of light neutrinos is limited to N{sub nu}<3.9 (4.8) at the 90 (95)% confidence level. Limits are also placed on the mass of supersymmetric particles. (orig.).

  13. Sub-Shot-Noise Transmission Measurement Enabled by Active Feed-Forward of Heralded Single Photons

    Science.gov (United States)

    Sabines-Chesterking, J.; Whittaker, R.; Joshi, S. K.; Birchall, P. M.; Moreau, P. A.; McMillan, A.; Cable, H. V.; O'Brien, J. L.; Rarity, J. G.; Matthews, J. C. F.

    2017-07-01

    Harnessing the unique properties of quantum mechanics offers the possibility of delivering alternative technologies that can fundamentally outperform their classical counterparts. These technologies deliver advantages only when components operate with performance beyond specific thresholds. For optical quantum metrology, the biggest challenge that impacts on performance thresholds is optical loss. Here, we demonstrate how including an optical delay and an optical switch in a feed-forward configuration with a stable and efficient correlated photon-pair source reduces the detector efficiency required to enable quantum-enhanced sensing down to the detection level of single photons and without postselection. When the switch is active, we observe a factor of improvement in precision of 1.27 for transmission measurement on a per-input-photon basis compared to the performance of a laser emitting an ideal coherent state and measured with the same detection efficiency as our setup. When the switch is inoperative, we observe no quantum advantage.

  14. Evaluation of single photon and Geiger mode Lidar for the 3D Elevation Program

    Science.gov (United States)

    Stoker, Jason M.; Abdullah, Qassim; Nayegandhi, Amar; Winehouse, Jayna

    2016-01-01

    Data acquired by Harris Corporation’s (Melbourne, FL, USA) Geiger-mode IntelliEarth™ sensor and Sigma Space Corporation’s (Lanham-Seabrook, MD, USA) Single Photon HRQLS sensor were evaluated and compared to accepted 3D Elevation Program (3DEP) data and survey ground control to assess the suitability of these new technologies for the 3DEP. While not able to collect data currently to meet USGS lidar base specification, this is partially due to the fact that the specification was written for linear-mode systems specifically. With little effort on part of the manufacturers of the new lidar systems and the USGS Lidar specifications team, data from these systems could soon serve the 3DEP program and its users. Many of the shortcomings noted in this study have been reported to have been corrected or improved upon in the next generation sensors.

  15. Electromagnetically induced transparency and reduced speeds for single photons in a fully quantized model

    International Nuclear Information System (INIS)

    Purdy, Thomas; Ligare, Martin

    2003-01-01

    We introduce a simple model for electromagnetically induced transparency in which all fields are treated quantum mechanically. We study a system of three separated atoms at fixed positions in a one-dimensional multimode optical cavity. The first atom serves as the source for a single spontaneously emitted photon; the photon scatters from a three-level 'Λ'-configuration atom which interacts with an additional single-mode field coupling two of the atomic levels; the third atom serves as a detector of the total transmitted field. We find an analytical solution for the quantum dynamics. From the quantum amplitude describing the excitation of the detector atom we extract information that provides exact single-photon analogues to wave delays predicted by semi-classical theories. We also find complementary information in the expectation value of the electric field intensity operator

  16. Analysis of single-photon time resolution of FBK silicon photomultipliers

    International Nuclear Information System (INIS)

    Acerbi, Fabio; Ferri, Alessandro; Gola, Alberto; Zorzi, Nicola; Piemonte, Claudio

    2015-01-01

    We characterized and analyzed an important feature of silicon photomultipliers: the single-photon time resolution (SPTR). We characterized the SPTR of new RGB (Red–Green–Blue) type Silicon Photomultipliers and SPADs produced at FBK (Trento, Italy), studying its main limiting factors. We compared time resolution of 1×1 mm 2 and 3×3 mm 2 SiPMs and a single SiPM cell (i.e. a SPAD with integrated passive-quenching), employing a mode-locked pulsed laser with 2-ps wide pulses. We estimated the contribution of front-end electronic-noise, of cell-to-cell uniformity, and intrinsic cell time-resolution. At a single-cell level, we compared the results obtained with different layouts. With a circular cell with a top metallization covering part of the edge and enhancing the signal extraction, we reached ~20 ps FWHM of time resolution

  17. Analysis of single-photon time resolution of FBK silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Acerbi, Fabio, E-mail: acerbi@fbk.eu; Ferri, Alessandro; Gola, Alberto; Zorzi, Nicola; Piemonte, Claudio

    2015-07-01

    We characterized and analyzed an important feature of silicon photomultipliers: the single-photon time resolution (SPTR). We characterized the SPTR of new RGB (Red–Green–Blue) type Silicon Photomultipliers and SPADs produced at FBK (Trento, Italy), studying its main limiting factors. We compared time resolution of 1×1 mm{sup 2} and 3×3 mm{sup 2} SiPMs and a single SiPM cell (i.e. a SPAD with integrated passive-quenching), employing a mode-locked pulsed laser with 2-ps wide pulses. We estimated the contribution of front-end electronic-noise, of cell-to-cell uniformity, and intrinsic cell time-resolution. At a single-cell level, we compared the results obtained with different layouts. With a circular cell with a top metallization covering part of the edge and enhancing the signal extraction, we reached ~20 ps FWHM of time resolution.

  18. arXiv Single-electron and single-photon sensitivity with a silicon Skipper CCD

    CERN Document Server

    Tiffenberg, Javier; Drlica-Wagner, Alex; Essig, Rouven; Guardincerri, Yann; Holland, Steve; Volansky, Tomer; Yu, Tien-Tien

    2017-09-26

    We have developed ultralow-noise electronics in combination with repetitive, nondestructive readout of a thick, fully depleted charge-coupled device (CCD) to achieve an unprecedented noise level of 0.068  e- rms/pixel. This is the first time that discrete subelectron readout noise has been achieved reproducible over millions of pixels on a stable, large-area detector. This enables the contemporaneous, discrete, and quantized measurement of charge in pixels, irrespective of whether they contain zero electrons or thousands of electrons. Thus, the resulting CCD detector is an ultra-sensitive calorimeter. It is also capable of counting single photons in the optical and near-infrared regime. Implementing this innovative non-destructive readout system has a negligible impact on CCD design and fabrication, and there are nearly immediate scientific applications. As a particle detector, this CCD will have unprecedented sensitivity to low-mass dark matter particles and coherent neutrino-nucleus scattering, while ...

  19. Performance Analysis of Single Photon Avalanche Diode Underwater VLC System Using ARQ

    KAUST Repository

    Shafiqu, Taniya

    2017-08-24

    Single photon avalanche diode (SPAD) has recently been introduced as a powerful detector for long distance underwater visible light (UVLC) communication. In this paper, the performance of the SPAD detector in UVLC is analyzed considering the effect of the turbulence induced fading resulting from air bubbles in addition to the combined effect of attenuation and scattering. Automatic repeat request (ARQ) system is adopted to mitigate different underwater impairments and reduce the error probability at the receiver side. Approximate packet error rate (PER) expressions are derived using Laguerre Gauss polynomial for a finite number of transmission. Next, the average energy efficiency and throughput are analyzed to account for the increased energy consumption cost and the decreased effective transmission rate, which results from adopting the ARQ scheme. Finally, different numerical results are introduced to verify the derived PER expressions, demonstrate the ability of the proposed ARQ system in extending the transmission range, and show the trade-off between energy efficiency (EE) and throughput.

  20. An ultrafast NbN hot-electron single-photon detector for electronic applications

    International Nuclear Information System (INIS)

    Lipatov, A; Okunev, O; Smirnov, K; Chulkova, G; Korneev, A; Kouminov, P; Gol'tsman, G; Zhang, J; Slysz, W; Verevkin, A; Sobolewski, R

    2002-01-01

    We present the latest generation of our superconducting single-photon detector (SPD), which can work from ultraviolet to mid-infrared optical radiation wavelengths. The detector combines a high speed of operation and low jitter with high quantum efficiency (QE) and very low dark count level. The technology enhancement allows us to produce ultrathin (3.5 nm thick) structures that demonstrate QE hundreds of times better, at 1.55 μm, than previous 10 nm thick SPDs. The best, 10x10 μm 2 , SPDs demonstrate QE up to 5% at 1.55 μm and up to 11% at 0.86 μm. The intrinsic detector QE, normalized to the film absorption coefficient, reaches 100% at bias currents above 0.9 I c for photons with wavelengths shorter than 1.3 μm

  1. Brain perfusion single photon emission computed tomography in major psychiatric disorders: From basics to clinical practice

    International Nuclear Information System (INIS)

    Santra, Amburanjan; Kumar, Rakesh

    2014-01-01

    Brain single photon emission computed tomography (SPECT) is a well-established and reliable method to assess brain function through measurement of regional cerebral blood flow (rCBF). It can be used to define a patient's pathophysiological status when neurological or psychiatric symptoms cannot be explained by anatomical neuroimaging findings. Though there is ample evidence validating brain SPECT as a technique to track human behavior and correlating psychiatric disorders with dysfunction of specific brain regions, only few psychiatrists have adopted brain SPECT in routine clinical practice. It can be utilized to evaluate the involvement of brain regions in a particular patient, to individualize treatment on basis of SPECT findings, to monitor the treatment response and modify treatment, if necessary. In this article, we have reviewed the available studies in this regard from existing literature and tried to present the evidence for establishing the clinical role of brain SPECT in major psychiatric illnesses

  2. Thallium-201 myocardial imaging with single photon emission CT in Kawasaki disease

    International Nuclear Information System (INIS)

    Matsumoto, Syuhei

    1992-01-01

    Seventy-five patients with Kawasaki disease underwent single photon emission computed tomography (SPECT) and planar imaging with thallium-201 after dipyridamole in order to evaluate the usefulness of detecting the complication of coronary artery disease (CAD). The results of SPECT with a three reconstruction imaging study (short axis, vertical long axis, horizontal long axis) and of planar imaging study with thallium-201 were compared with coronary angiography. The overall sensitivity of detecting CAD was 86.7% with SPECT and 66.7% with planar imaging. The sensitivity in identifying individual vessels was 76.0% with SPECT and 44.0% with planar imaging. SPECT was especially superior to planar imaging in detecting localized stenosis. (53.8% vs 15.4%) The specificity of SPECT did not differ from the planar imaging study. Dipyridamole thallium-201 SPECT is a useful non-invasive method to detect CAD due to Kawasaki disease. (author)

  3. Threshold behavior in single-photon double ionization of atomic oxygen

    Science.gov (United States)

    He, Z. X.; Moberg, R.; Samson, J. A. R.

    1995-12-01

    The threshold behavior of the single-photon double-ionization cross section of atomic oxygen has been studied using vacuum uv radiation from a synchrotron storage ring. The double-ionization cross section appears to follow a power law Eα (where E is the kinetic energy of the two electrons) from its threshold to about 2.0 eV above with an exponent α=1.08+/-0.03, which is consistent with Wannier's theoretical value of 1.056. The cross section also shows the influence of the doubly excited 2s2p3nln'l' (n,n'>~3) neutral states, among which the first three converge to the 2s2p3(5So)4p(6Po) ionic state of oxygen.

  4. Control of single-photon routing in a T-shaped waveguide by another atom

    Science.gov (United States)

    Huang, Jin-Song; Wang, Jing-Wen; Wang, Yan; Li, Yan-Ling; Huang, You-Wen

    2018-04-01

    Quantum routers with a high routing rate of much more than 0.5 are of great importance for quantum networks. We provide a scheme to perform bidirectional high routing-rate transfer in a T-shaped coupled-resonator waveguide (CRW), which extends a recent unidirectional scheme proposed by Lu et al. (Opt Express 23:22955, 2015). By locating an extra two-level atom in the infinite CRW channel of the T-shaped CRW with a three-level system, an effective potential is generated. Our numerical results show that high routing capability from the infinite CRW channel to the semi-infinite channel can be achieved, and routing capability from the semi-infinite CRW channel to the infinite channel can also be significantly enhanced, with the help of the effective potential. Therefore, the proposed double-atom configuration could be utilized as a bidirectional quantum routing controller to implement high transfer rate routing of single photons.

  5. Spectrum of single photon emission computed tomography/computed tomography findings in patients with parathyroid adenomas.

    Science.gov (United States)

    Chakraborty, Dhritiman; Mittal, Bhagwant Rai; Harisankar, Chidambaram Natrajan Balasubramanian; Bhattacharya, Anish; Bhadada, Sanjay

    2011-01-01

    Primary hyperparathyroidism results from excessive parathyroid hormone secretion. Approximately 85% of all cases of primary hyperparathyroidism are caused by a single parathyroid adenoma; 10-15% of the cases are caused by parathyroid hyperplasia. Parathyroid carcinoma accounts for approximately 3-4% of cases of primary disease. Technetium-99m-sestamibi (MIBI), the current scintigraphic procedure of choice for preoperative parathyroid localization, can be performed in various ways. The "single-isotope, double-phase technique" is based on the fact that MIBI washes out more rapidly from the thyroid than from abnormal parathyroid tissue. However, not all parathyroid lesions retain MIBI and not all thyroid tissue washes out quickly, and subtraction imaging is helpful. Single photon emission computed tomography (SPECT) provides information for localizing parathyroid lesions, differentiating thyroid from parathyroid lesions, and detecting and localizing ectopic parathyroid lesions. Addition of CT with SPECT improves the sensitivity. This pictorial assay demonstrates various SPECT/CT patterns observed in parathyroid scintigraphy.

  6. Single-photon detectors combining high efficiency, high detection rates, and ultra-high timing resolution

    Directory of Open Access Journals (Sweden)

    Iman Esmaeil Zadeh

    2017-11-01

    Full Text Available Single-photon detection with high efficiency, high time resolution, low dark counts, and high photon detection rates is crucial for a wide range of optical measurements. Although efficient detectors have been reported before, combining all performance parameters in a single device remains a challenge. Here, we show a broadband NbTiN superconducting nanowire detector with an efficiency exceeding 92%, over 150 MHz photon detection rate, and a dark count rate below 130 Hz operated in a Gifford-McMahon cryostat. Furthermore, with careful optimization of the detector design and readout electronics, we reach an ultra-low system timing jitter of 14.80 ps (13.95 ps decoupled while maintaining high detection efficiencies (>75%.

  7. Gating circuit for single photon-counting fluorescence lifetime instruments using high repetition pulsed light sources

    International Nuclear Information System (INIS)

    Laws, W.R.; Potter, D.W.; Sutherland, J.C.

    1984-01-01

    We have constructed a circuit that permits conventional timing electronics to be used in single photon-counting fluorimeters with high repetition rate excitation sources (synchrotrons and mode-locked lasers). Most commercial time-to-amplitude and time-to-digital converters introduce errors when processing very short time intervals and when subjected to high-frequency signals. This circuit reduces the frequency of signals representing the pulsed light source (stops) to the rate of detected fluorescence events (starts). Precise timing between the start/stop pair is accomplished by using the second stop pulse after a start pulse. Important features of our design are that the circuit is insensitive to the simultaneous occurrence of start and stop signals and that the reduction in the stop frequency allows the start/stop time interval to be placed in linear regions of the response functions of commercial timing electronics

  8. Brain perfusion single photon emission computed tomography in children after acute encephalopathy

    International Nuclear Information System (INIS)

    Kurihara, Mana; Nakae, Yoichiro; Kohagizawa, Toshitaka; Eto, Yoshikatsu

    2005-01-01

    We studied single photon emission computed tomography (SPECT) of 15 children with acute encephalopathy after more than 1 year from the onset, using technetium-99 m-L, L-ethyl cystinate dimer ( 99m Tc-ECD) and a three-dementional stereotaxic region of interest template. Regional cerebral blood flow was evaluated and divided in three groups according to the severity of disability: absent or mild, moderate, and severe. There was no abnormality on SPECT in the patients without disability or with mild disability. Diffuse hypoperfusion was shown in the groups with moderate and severe disability. The patients with severe disability showed hypoperfusion in the pericallosal, frontal and central areas which was more pronounced than in the patients with moderate disability. (author)

  9. A direct measurement of the invisible width of the Z from single photon counting

    Science.gov (United States)

    Buskulic, D.; de Bonis, I.; Decamp, D.; Ghez, P.; Goy, C.; Lees, J.-P.; Minard, M.-N.; Pietrzyk, B.; Ariztizabal, F.; Comas, P.; Crespo, J. M.; Delfino, M.; Efthymiopoulos, I.; Fernandez, E.; Fernandez-Bosman, M.; Gaitan, V.; Garrido, Ll.; Mattison, T.; Pacheco, A.; Padilla, C.; Pasual, A.; Creanza, D.; de Palma, M.; Farilla, A.; Iaselli, G.; Maggi, G.; Natali, S.; Nuzzo, S.; Quattromini, M.; Ranieri, A.; Raso, G.; Romano, F.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Zito, G.; Chai, Y.; Hu, H.; Huang, D.; Huang, X.; Lin, J.; Wang, T.; Xie, Y.; Xu, D.; Xu, R.; Zhang, J.; Zhang, L.; Zhao, W.; Blucher, E.; Bonvicini, G.; Boudreau, J.; Casper, D.; Drevermann, H.; Forty, R. W.; Ganis, G.; Gay, C.; Hagelberg, R.; Harvey, J.; Hilgart, J.; Jacobsen, R.; Jost, B.; Knobloch, J.; Lehraus, I.; Lohse, T.; Maggi, M.; Markou, C.; Martinez, M.; Mato, P.; Meinhard, H.; Minten, A.; Miotto, A.; Miquel, R.; Moser, H.-G.; Palazzi, P.; Pater, J. R.; Perlas, J. A.; Pusztaszeri, J.-F.; Ranjard, F.; Redlinger, G.; Rolandi, L.; Rothberg, J.; Ruan, T.; Saich, M.; Schlatter, D.; Schmelling, M.; Sefkow, F.; Tejessy, W.; Tomalin, I. R.; Veenhof, R.; Wachsmuth, H.; Wasserbaech, S.; Wiedenmann, W.; Wildish, T.; Witzeling, W.; Wotschack, J.; Atjaltouni, Z.; Badaud, F.; Bardadin-Otwinowska, M.; El Fellous, R.; Falvard, A.; Gay, P.; Guicheney, C.; Henrard, P.; Jousset, J.; Michel, B.; Montret, J.-C.; Pallin, D.; Perret, P.; Podlyski, F.; Proriol, J.; Prulhière, F.; Saadi, F.; Fearnley, T.; Hansen, J. B.; Hansen, J. D.; Hansen, J. R.; Hansen, P. H.; Møllerud, R.; Nilsson, B. S.; Kyriakis, A.; Simopoulou, E.; Siotis, I.; Vayaki, A.; Zachariadou, K.; Badier, J.; Blondel, A.; Bonneaud, G.; Brient, J. C.; Fouque, G.; Orteu, S.; Rougé, A.; Rumpf, M.; Tanaka, R.; Verderi, M.; Videau, H.; Candlin, D. J.; Parsons, M. I.; Veitch, E.; Focardi, E.; Moneta, L.; Parrini, G.; Corden, M.; Georgiopoulos, C.; Ikeda, M.; Levinthal, D.; Antonelli, A.; Baldini, R.; Bencivenni, G.; Bologna, G.; Bossi, F.; Campana, P.; Capon, G.; Cerutti, F.; Chiarella, V.; D'Ettorre-Piazzoli, B.; Felici, G.; Laurelli, P.; Mannocchi, G.; Murtas, F.; Murtas, G. P.; Passalacqua, L.; Pepe-Altarelli, M.; Picchi, P.; Colrain, P.; Ten Have, I.; Lynch, J. G.; Maitland, W.; Morton, W. T.; Raine, C.; Reeves, P.; Scarr, J. M.; Smith, K.; Smith, M. G.; Thompson, A. S.; Turnbull, R. M.; Brandl, B.; Braun, O.; Geweniger, C.; Hanke, P.; Hepp, V.; Kluge, E. E.; Maumary, Y.; Putzer, A.; Rensch, B.; Stahl, A.; Tittel, K.; Wunsch, M.; Beuselinck, R.; Binnie, D. M.; Cameron, W.; Cattaneo, M.; Colling, D. J.; Dornan, P. J.; Greene, A. M.; Hassard, J. F.; Lieske, N. M.; Moutoussi, A.; Nash, J.; Patton, S.; Payne, D. G.; Phillips, M. J.; San Martin, G.; Sedgbeer, J. K.; Wright, A. G.; Girtler, P.; Kuhn, D.; Rudolph, G.; Vogl, R.; Bowdery, C. K.; Brodbeck, T. J.; Finch, A. J.; Foster, F.; Hughes, G.; Jackson, D.; Keemer, N. R.; Nuttall, M.; Petl, A.; Sloan, T.; Snow, S. W.; Whelan, E. P.; Kleinknecht, K.; Raab, J.; Renk, B.; Sander, H.-G.; Schmidt, H.; Steeg, F.; Walther, S. M.; Wanke, R.; Wolf, B.; Bencheikh, A. M.; Benchouk, C.; Bonissent, A.; Carr, J.; Coyle, P.; Drinkard, J.; Etienne, F.; Nicod, D.; Papalexiou, S.; Payre, P.; Roos, L.; Rousseau, D.; Schwemling, P.; Talby, M.; Adlung, S.; Assmann, R.; Bauer, C.; Blum, W.; Brown, D.; Cattaneo, P.; Dehning, B.; Dietl, H.; Dydak, F.; Frank, M.; Halley, A. W.; Jakobs, K.; Lauber, J.; Lütjens, G.; Lutz, G.; Männer, W.; Richter, R.; Schröder, J.; Schwarz, A. S.; Settles, R.; Seywerd, H.; Stielin, U.; Stiegler, U.; St. Denis, R.; Wolf, G.; Alemany, R.; Boucrot, J.; Callot, O.; Cordier, A.; Davier, M.; Duflot, L.; Grivaz, J.-F.; Heusse, Ph.; Jaffe, D. E.; Janot, P.; Kim, D. W.; Le Diberder, F.; Lefrançois, J.; Lutz, A.-M.; Schune, M.-H.; Veillet, J.-J.; Videau, I.; Zhang, Z.; Abbaneo, D.; Bagliesi, G.; Batignani, G.; Bottigli, U.; Bozzi, C.; Calderini, G.; Carpinelli, M.; Ciocci, M. A.; Ciulli, V.; dell'Orso, R.; Ferrante, I.; Fidecaro, F.; Foà, L.; Forti, F.; Giassi, A.; Giorgi, M. A.; Gregorio, A.; Ligabue, F.; Lusiani, A.; Mannelli, E. B.; Marrocchesi, P. S.; Messineo, A.; Palla, F.; Sanguinetti, G.; Spagnolo, P.; Steinberger, J.; Tenchini, R.; Tonelli, G.; Triggiani, G.; Valassi, A.; Vannini, C.; Venturi, A.; Verdini, P. G.; Walsh, J.; Betteridge, A. P.; Gao, Y.; Green, M. G.; March, P. V.; Mir, Ll. M.; Medcalf, T.; Quazi, I. S.; Strong, J. A.; West, L. R.; Botteril, D. R.; Clifft, R. W.; Edgecock, T. R.; Haywood, S.; Norton, P. R.; Thompson, J. C.; Bloch-Devaux, B.; Colas, P.; Duarte, H.; Emery, S.; Kozanecki, W.; Lançon, E.; Lemaire, M. C.; Locci, E.; Marx, B.; Perez, P.; Rander, J.; Renardy, J.-F.; Rosowsky, A.; Roussarie, A.; Schuller, J.-P.; Schwindling, J.; Si Mohand, D.; Vallage, B.; Johnson, R. P.; Litke, A. M.; Taylor, G.; Wear, J.; Ashman, J. G.; Babbage, W.; Booth, C. N.; Buttar, C.; Cartwright, S.; Combley, F.; Dawson, I.; Thompson, L. F.; Barberio, E.; Böhrer, A.; Brandt, S.; Cowan, G.; Grupen, C.; Lutters, G.; Rivera, F.; Schäfer, U.; Smolik, L.; Bosisio, L.; della Marina, R.; Giannini, G.; Gobbo, B.; Ragusa, F.; Bellatoni, L.; Chen, W.; Conway, J. S.; Feng, Z.; Ferguson, D. P. S.; Gao, Y. S.; Grahl, J.; Harton, J. L.; Hayes, O. J.; Nachtman, J. M.; Pan, Y. B.; Saadi, Y.; Schmitt, M.; Scott, I.; Sharma, V.; Shi, Z. H.; Turk, J. D.; Walsh, A. M.; Weber, F. V.; Sau, Lan, Wu; Wu, X.; Zheng, M.; Zobernig, G.

    1993-09-01

    The ALEPH detector at LEP is used to study single photon events in e+e- collisions at the Z resonance. In a total data sample of 15.7 pb-1 taken in 1990 and 1991 scanning the resonance, 400 events were recorded where each has a single deposition of more than 1.5 GeV measured in the polar angular region cosθγ < 0.74 of the electromagnetic calorimeter. It is shown that this number of events cab be accounted for by known processes. After subtraction of background events, the invisible width of the Z is determined to be 45 +/- 34(stat.) +/- 34(syst.) MeV. Using Z. resonance parameters derived by ALEPH, the corresponding number oflight neutrino generations is found to be 2.68 +/- 0.20(stat.) +/- 0.20(syst.). Supported by the US Department of Energy, contract DE-ACO2-76ER00881.

  10. Potential new approaches for the development of brain imaging agents for single-photon applications

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F. Jr.; Srivastava, P.C.

    1984-01-01

    This paper describes new strategies for the brain-specific delivery of radionuclides that can be used to evaluate regional cerebral perfusion by single photon imaging techniques. A description of several examples of interesting new strategies that have recently been reported is presented. A new approach at this institution for the brain-specific delivery of radioiodinated iodophenylalkyl-substituted dihyronicotinamide systems is described which shows good brain uptake and retention in preliminary studies in rats. Following transport into the brain these agents appear to undergo facile intracerebral oxidation to the quaternized analogues which do not recross the intact blood-brain barrier and so are effectively trapped in the brain. 49 refs., 9 figs., 1 tab.

  11. Self-aligned multi-channel superconducting nanowire single-photon detectors.

    Science.gov (United States)

    Cheng, Risheng; Guo, Xiang; Ma, Xiaosong; Fan, Linran; Fong, King Y; Poot, Menno; Tang, Hong X

    2016-11-28

    We describe a micromachining process to allow back-side coupling of an array of single-mode telecommunication fibers to individual superconducting nanowire single photon detectors (SNSPDs). This approach enables a back-illuminated detector structure which separates the optical access and electrical readout on two sides of the chip and thus allows for compact integration of multi-channel detectors. As proof of principle, we show the integration of four detectors on the same silicon chip with two different designs and their performances are compared. In the optimized design, the device shows saturated system detection efficiency of 16% while the dark count rate is less than 20 Hz, all achieved without the use of metal reflectors or distributed Bragg reflectors (DBRs). This back-illumination approach also eliminates the cross-talk between different detection channels.

  12. A multichannel single-photon sensitive detector for high-energy physics: the megapixel EBCCD

    CERN Document Server

    Benussi, L; Frekers, D; Frenkel, A; Giannini, G; Golovkin, S V; Kozarenko, E N; Kreslo, I E; Liberti, B; Martellotti, G; Medvedkov, A M; Mondardini, M R; Penso, G; Polizzi, A; Santacesaria, R; Santini, G; Spinetti, M; Vilain, P; Votano, L; Wilquet, G; Winter, Klaus

    2000-01-01

    We present a study of the characteristics of a hybrid image intensifier tube based on a thinned backside Electron Bombarded CCD (EBCCD) with better performance in spatial resolution, single photoelectron detection and gain stability than the conventional intensified systems based on a Micro Channel Plate followed by a CCD. Single photon detection sensitivity has been studied and a procedure to correct the gain non-uniformity of the EBCCD has been developed. The EBCCD, operating at 14 kV, has an average gain of approx 3000 electrons/photoelectron and a noise of the order of 100 electron/pixel. These characteristics make the EBCCD a very attractive device for many applications in high-energy physics, astrophysics and biomedicine. A possible application in a neutrino oscillation experiment is presented.

  13. Single-photon emission associated with double electron capture in F9+ + C collisions

    CERN Document Server

    Elkafrawy, Tamer; Tanis, John A; Warczak, Andrzej

    2016-01-01

    Radiative double electron capture (RDEC), the one-step process occurring in ion-atom collisions, has been investigated for bare fluorine ions colliding with carbon. RDEC is completed when two target electrons are captured to a bound state of a projectile simultaneously with the emission of a single photon. This work is a follow-up to our earlier measurement of RDEC for bare oxygen projectiles, thus providing a recipient system free of electron-related Coulomb fields in both cases and allowing for the comparison between the two collision systems as well as with available theoretical studies. The most significant mechanisms of x-ray emission that may contribute to the RDEC energy region as background processes are also addressed.

  14. Fundamental limits to single-photon detection determined by quantum coherence and backaction

    Science.gov (United States)

    Young, Steve M.; Sarovar, Mohan; Léonard, François

    2018-03-01

    Single-photon detectors have achieved impressive performance and have led to a number of new scientific discoveries and technological applications. Existing models of photodetectors are semiclassical in that the field-matter interaction is treated perturbatively and time-separated from physical processes in the absorbing matter. An open question is whether a fully quantum detector, whereby the optical field, the optical absorption, and the amplification are considered as one quantum system, could have improved performance. Here we develop a theoretical model of such photodetectors and employ simulations to reveal the critical role played by quantum coherence and amplification backaction in dictating the performance. We show that coherence and backaction lead to trade-offs between detector metrics and also determine optimal system designs through control of the quantum-classical interface. Importantly, we establish the design parameters that result in a ideal photodetector with 100% efficiency, no dark counts, and minimal jitter, thus paving the route for next-generation detectors.

  15. Hot water epilepsy: Phenotype and single photon emission computed tomography observations

    Directory of Open Access Journals (Sweden)

    Mehul Patel

    2014-01-01

    Full Text Available We studied the anatomical correlates of reflex hot water epilepsy (HWE using multimodality investigations viz. magnetic resonance imaging (MRI, electroencephalography (EEG, and single photon emission computed tomography (SPECT. Five men (mean age: 27.0 ΁ 5.8 years with HWE were subjected to MRI of brain, video-EEG studies, and SPECT scan. These were correlated with phenotypic presentations. Seizures could be precipitated in three patients with pouring of hot water over the head and semiology of seizures was suggestive of temporal lobe epilepsy. Ictal SPECT showed hyperperfusion in: left medial temporal - one, left lateral temporal - one, and right parietal - one. Interictal SPECT was normal in all five patients and did not help in localization. MRI and interictal EEG was normal in all the patients. The clinical and SPECT studies suggested temporal lobe as the seizure onset zone in some of the patients with HWE.

  16. Dead time effect on single photon counting for the longitudinal density monitor of LHC

    CERN Document Server

    Bravin, E

    2005-01-01

    The longitudinal distribution of the protons in the two LHC rings needs to be known with high accuracy. This is required for both: the correct operation of the machine and the understanding of beam dynamics effects that can influence the performances of the collider. One possible way of achieving the required time resolution of 50 ps and dynamic range of 10.4 is single photons counting of the synchrotron radiation emitted by the beams using avalanche photo diodes (APDs). Although this kind of devices have very short rise times and allow precise time stamping of detected photons, they also have long recovery times (dead time) of the order of hundreds of nanoseconds, much longer than the bunch length of the LHC beams. For this reason it is important to evaluate the masking effect introduced by this dead time, where photons emitted by protons in different longitudinal positions will have different probabilities of being detected.

  17. Dead time effect on single photon counting for the longitudinal density monitor LHC

    CERN Document Server

    Bravin, E

    2005-01-01

    The longitudinal distribution of the protons in the two LHC rings needs to be known with high accuracy. This is required for both: the correct operation of the machine and the understanding of beam dynamics effects that can influence the performances of the collider. One possible way of achieving the required time resolution of 50 ps and dynamic range of 10.4 is single photons counting of the synchrotron radiation emitted by the beams using avalanche photo diodes (APDs). Although this kind of devices have very short rise times and allow precise time stamping of detected photons, they also have long recovery times (dead time) of the order of humdreds of nanoseconds, much longer than the bunch length of the LHC beams. For this reason it is important to evaluate the masking effect introduced by this dead time, where photons emitted by protons in different longitudinal positions will have different probabilities of being detected.

  18. Single-photon emission computed tomography in human immunodeficiency virus encephalopathy: A preliminary report

    International Nuclear Information System (INIS)

    Masdeu, J.C.; Yudd, A.; Van Heertum, R.L.; Grundman, M.; Hriso, E.; O'Connell, R.A.; Luck, D.; Camli, U.; King, L.N.

    1991-01-01

    Depression or psychosis in a previously asymptomatic individual infected with the human immunodeficiency virus (HIV) may be psychogenic, related to brain involvement by the HIV or both. Although prognosis and treatment differ depending on etiology, computed tomography (CT) and magnetic resonance imaging (MRI) are usually unrevealing in early HIV encephalopathy and therefore cannot differentiate it from psychogenic conditions. Thirty of 32 patients (94%) with HIV encephalopathy had single-photon emission computed tomography (SPECT) findings that differed from the findings in 15 patients with non-HIV psychoses and 6 controls. SPECT showed multifocal cortical and subcortical areas of hypoperfusion. In 4 cases, cognitive improvement after 6-8 weeks of zidovudine (AZT) therapy was reflected in amelioration of SPECT findings. CT remained unchanged. SPECT may be a useful technique for the evaluation of HIV encephalopathy

  19. Room-Temperature Single-photon level Memory for Polarization States

    Science.gov (United States)

    Kupchak, Connor; Mittiga, Thomas; Jordaan, Bertus; Namazi, Mehdi; Nölleke, Christian; Figueroa, Eden

    2015-01-01

    An optical quantum memory is a stationary device that is capable of storing and recreating photonic qubits with a higher fidelity than any classical device. Thus far, these two requirements have been fulfilled for polarization qubits in systems based on cold atoms and cryogenically cooled crystals. Here, we report a room-temperature memory capable of storing arbitrary polarization qubits with a signal-to-background ratio higher than 1 and an average fidelity surpassing the classical benchmark for weak laser pulses containing 1.6 photons on average, without taking into account non-unitary operation. Our results demonstrate that a common vapor cell can reach the low background noise levels necessary for polarization qubit storage using single-photon level light, and propels atomic-vapor systems towards a level of functionality akin to other quantum information processing architectures.

  20. single photon emission tomography and positron emission tomography - Part 1 (October 2012), Part 2 (October 2010)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2010-10-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) and the positron emission tomography (PET) imaging techniques. Part 1 Content: 1 - Introduction: anatomic, functional and molecular imaging; 2 - Radiotracers: chemical and physical constraints, gamma photon emitters, positon emitters, radioisotopes production, emitters type and imaging techniques; 3 - Gamma cameras; 4 - Quantification in emission tomography: attenuation, scattering, un-stationary spatial resolution; 5 - Synthesis and conclusion. Part 2 content: 1 - Positon emitters; 2 - Positons detection: Coincidence detection (electronic collimation, PET detectors with gamma cameras, dedicated PET detectors, spectrometry); PET detectors type; time-of-flight PET; 2D PET; 3D PET; 3 - Quantification in emission tomography: detected events, attenuation, scattering, fortuitous coincidences, standardisation; 4 - Common SPECT and PET problems: partial volume effect, movement, tomographic reconstruction, calibration, dead time; 5 - Synthesis and conclusion

  1. The contribution of single photon emission computed tomography in the clinical assessment of Alzheimer type dementia

    International Nuclear Information System (INIS)

    Boudousq, V.; Collombier, L.; Kotzki, P.O.

    1999-01-01

    Interest of brain single-photon emission computed tomography to support clinical diagnosis of Alzheimer-type dementia is now established. Numerous studies have reported a decreased perfusion in the association cortex of the parietal lobe and the posterior temporal regions. In patients with mild cognitive complaints, the presence of focal hypoperfusion may increase substantially the probability of the disease. In addition, emission tomography emerges as a helpful tool in situation in which there is diagnostic doubt. In this case, the presence of temporo-parietal perfusion deficit associated with hippocampal atrophy on MRI or X-ray computed tomography contributes to diagnostic accuracy. However, some studies suggest that emission tomography may be useful for preclinical prediction of Alzheimer's disease and to predict cognitive decline. (author)

  2. Picosecond UV single photon detectors with lateral drift field: Concept and technologies

    Energy Technology Data Exchange (ETDEWEB)

    Yakimov, M.; Oktyabrsky, S.; Murat, P.

    2015-09-01

    Group III–V semiconductor materials are being considered as a Si replacement for advanced logic devices for quite some time. Advances in III–V processing technologies, such as interface and surface passivation, large area deep submicron lithography with high-aspect ratio etching primarily driven by the metal-oxide-semiconductor field-effect transistor development can also be used for other applications. In this paper we will focus on photodetectors with the drift field parallel to the surface. We compare the proposed concept to the state-of-the-art Si-based technology and discuss requirements which need to be satisfied for such detectors to be used in a single photon counting mode in blue and ultraviolet spectral region with about 10 ps photon timing resolution essential for numerous applications ranging from high-energy physics to medical imaging.

  3. Geiger-mode APD camera system for single-photon 3D LADAR imaging

    Science.gov (United States)

    Entwistle, Mark; Itzler, Mark A.; Chen, Jim; Owens, Mark; Patel, Ketan; Jiang, Xudong; Slomkowski, Krystyna; Rangwala, Sabbir

    2012-06-01

    The unparalleled sensitivity of 3D LADAR imaging sensors based on single photon detection provides substantial benefits for imaging at long stand-off distances and minimizing laser pulse energy requirements. To obtain 3D LADAR images with single photon sensitivity, we have demonstrated focal plane arrays (FPAs) based on InGaAsP Geiger-mode avalanche photodiodes (GmAPDs) optimized for use at either 1.06 μm or 1.55 μm. These state-of-the-art FPAs exhibit excellent pixel-level performance and the capability for 100% pixel yield on a 32 x 32 format. To realize the full potential of these FPAs, we have recently developed an integrated camera system providing turnkey operation based on FPGA control. This system implementation enables the extremely high frame-rate capability of the GmAPD FPA, and frame rates in excess of 250 kHz (for 0.4 μs range gates) can be accommodated using an industry-standard CameraLink interface in full configuration. Real-time data streaming for continuous acquisition of 2 μs range gate point cloud data with 13-bit time-stamp resolution at 186 kHz frame rates has been established using multiple solid-state storage drives. Range gate durations spanning 4 ns to 10 μs provide broad operational flexibility. The camera also provides real-time signal processing in the form of multi-frame gray-scale contrast images and single-frame time-stamp histograms, and automated bias control has been implemented to maintain a constant photon detection efficiency in the presence of ambient temperature changes. A comprehensive graphical user interface has been developed to provide complete camera control using a simple serial command set, and this command set supports highly flexible end-user customization.

  4. Fast single-photon imager acquires 1024 pixels at 100 kframe/s

    Science.gov (United States)

    Guerrieri, Fabrizio; Tisa, Simone; Zappa, Franco

    2009-02-01

    We present the design and we discuss in depth the operating conditions of a two-dimensional (2-D) imaging array of single-photon detectors that provides a total of 1024 pixels, laid out in 32 rows by 32 columns array, integrated within a monolithic silicon chip with dimensions of 3.5 mm x 3.5 mm. We employed a standard high-voltage 0.35μm CMOS fabrication technology, with no need of any custom processing. Each pixel consists of one Single-Photon Avalanche Diode (SPAD) and a compact front-end analog electronics followed by a digital processing circuitry. The in-pixel front-end electronics senses the ignition of the avalanche, quenches the detector, provides a pulse and restores the detector for detecting a subsequent photon. The processing circuitry counts events (both photon and unwelcome "noise" ignition) within user-selectable integration time-slots and stores the count into an in-pixel memory cell, which is read-out in 10 ns/pixel. Such a two-levels pipeline architecture allows to acquire the actual frame while contemporary reading out the previous one, thus achieving a very high free-running frame rate, with negligible inter-frame dead-time. Each pixel is therefore a completely independent photon-counter. The measured Photo Detection Efficiency (PDE) tops 43% at 5V excess-bias, while the Dark-Counting Rate (DCR) is below 4kcps (counts per second) at room temperature. The maximum frame-rate depends on the system clock; with a convenient 100MHz system clock we achieved a free-running speed of 100 kframe/s from the all 1024 pixels.

  5. 8-channel acquisition system for time-correlated single-photon counting

    Science.gov (United States)

    Antonioli, S.; Miari, L.; Cuccato, A.; Crotti, M.; Rech, I.; Ghioni, M.

    2013-06-01

    Nowadays, an increasing number of applications require high-performance analytical instruments capable to detect the temporal trend of weak and fast light signals with picosecond time resolution. The Time-Correlated Single-Photon Counting (TCSPC) technique is currently one of the preferable solutions when such critical optical signals have to be analyzed and it is fully exploited in biomedical and chemical research fields, as well as in security and space applications. Recent progress in the field of single-photon detector arrays is pushing research towards the development of high performance multichannel TCSPC systems, opening the way to modern time-resolved multi-dimensional optical analysis. In this paper we describe a new 8-channel high-performance TCSPC acquisition system, designed to be compact and versatile, to be used in modern TCSPC measurement setups. We designed a novel integrated circuit including a multichannel Time-to-Amplitude Converter with variable full-scale range, a D/A converter, and a parallel adder stage. The latter is used to adapt each converter output to the input dynamic range of a commercial 8-channel Analog-to-Digital Converter, while the integrated DAC implements the dithering technique with as small as possible area occupation. The use of this monolithic circuit made the design of a scalable system of very small dimensions (95 × 40 mm) and low power consumption (6 W) possible. Data acquired from the TCSPC measurement are digitally processed and stored inside an FPGA (Field-Programmable Gate Array), while a USB transceiver allows real-time transmission of up to eight TCSPC histograms to a remote PC. Eventually, the experimental results demonstrate that the acquisition system performs TCSPC measurements with high conversion rate (up to 5 MHz/channel), extremely low differential nonlinearity (<0.04 peak-to-peak of the time bin width), high time resolution (down to 20 ps Full-Width Half-Maximum), and very low crosstalk between channels.

  6. Calibration of a single-photon counting detectors without the need of input photon flux calibration (Conference Presentation)

    Science.gov (United States)

    Gerrits, Thomas

    2017-05-01

    Calibration of fiber-coupled single-photon detectors usually requires knowledge of the input photon flux inside the fiber and/or knowledge of the linearity of a reference power meter. Many approaches have been presented in the past to accurately measure the photon detection probability of a single photon detector [1-6]. Under certain assumptions, one can utilize waveguide-coupled single photon detectors and a series of photon-counting measurements and a single-photon source to calibrate the detection efficiency of a single photon detector without the need of a reference power meter and the knowledge of the incoming photon flux. Here, this method is presented. Furthermore, if a reference detector is used, the detection efficiency of all evanescently coupled waveguide detectors can be measured, and the measurement outcome does not depend on splicing or fiber connection losses within in the setup, i.e., the measurement is setup-independent. In addition, the method, when using a reference detector, can be utilized to measure and distinguish between the absorption of a waveguide-coupled single photon detector and its internal detection efficiency. [1] A. J. Miller et al, Opt. Express 19, 9102-9110 (2011) [2] I. Muller et al., Metrologia 51, S329 (2014). [3] A. L. Migdall, Instrumentation and Measurement, IEEE Transactions on 50, 478-481 (2001). [4] S. V. Polyakov, A. L. Migdall, Optics Express 15, 1390-1407 (2007). [5] A. Avella et al., Optics Express 19, 23249-23257 (2011). [6] T. Lunghi et al., Opt. Express 22, 18078-18092 (2014)

  7. Tunable single photonic defect-mode in cholesteric liquid crystals with laser-induced local modifications of helix

    International Nuclear Information System (INIS)

    Yoshida, Hiroyuki; Lee, Chee Heng; Fujii, Akihiko; Ozaki, Masanori

    2006-01-01

    The authors demonstrate a tunable single photonic defect-mode in a single cholesteric liquid crystal material based on a structural defect introduced by local modification of the helix. An unpolymerized region of cholesteric liquid crystal acting as the defect was left between two polymerized regions via a two-photon excitation laser-lithography process. Upon polymerization, the cholesteric liquid crystal helix elongated and became thermally stable, and a single photonic defect mode was exhibited due to the contrast in the helix pitch at the defect. The defect mode showed tunability upon heating, and a 36 nm redshift was seen over a temperature range of 30 deg. C

  8. Single-Photon Source for Quantum Information Based on Single Dye Molecule Fluorescence in Liquid Crystal Host

    International Nuclear Information System (INIS)

    Lukishova, S.G.; Knox, R.P.; Freivald, P.; McNamara, A.; Boyd, R.W.; Stroud, Jr. C.R.; Schmid, A.W.; Marshall, K.L.

    2006-01-01

    This paper describes a new application for liquid crystals: quantum information technology. A deterministically polarized single-photon source that efficiently produces photons exhibiting antibunching is a pivotal hardware element in absolutely secure quantum communication. Planar-aligned nematic liquid crystal hosts deterministically align the single dye molecules which produce deterministically polarized single (antibunched) photons. In addition, 1-D photonic bandgap cholesteric liquid crystals will increase single-photon source efficiency. The experiments and challenges in the observation of deterministically polarized fluorescence from single dye molecules in planar-aligned glassy nematic-liquid-crystal oligomer as well as photon antibunching in glassy cholesteric oligomer are described for the first time

  9. Spectrally pure heralded single photons by spontaneous four-wave mixing in a fiber: reducing impact of dispersion fluctuations

    DEFF Research Database (Denmark)

    Koefoed, Jacob Gade; Friis, Søren Michael Mørk; Christensen, Jesper Bjerge

    2017-01-01

    We model the spectral quantum-mechanical purity of heralded single photons from a photon-pair source based on nondegenerate spontaneous four-wave mixing taking the impact of distributed dispersion fluctuations into account. The considered photon-pair-generation scheme utilizes pump-pulse walk......-off to produce pure heralded photons and phase matching is achieved through the dispersion properties of distinct spatial modes in a few-mode silica step-index fiber. We show that fiber-core-radius fluctuations in general severely impact the single-photon purity. Furthermore, by optimizing the fiber design we...... frequency. (C) 2017 Optical Society of America...

  10. Efficient fiber-coupled single-photon source based on quantum dots in a photonic-crystal waveguide

    DEFF Research Database (Denmark)

    Daveau, Raphaël S.; Balram, Krishna C.; Pregnolato, Tommaso

    2017-01-01

    Many photonic quantum information processing applications would benefit from a high brightness, fiber-coupled source of triggered single photons. Here, we present a fiber-coupled photonic-crystal waveguide (PCWG) singlephoton source relying on evanescent coupling of the light field from a tapered...... transfer it to the fiber. The applied outcoupling method is robust, stable over time, and broadband over several tens of nanometers, which makes it a highly promising pathway to increase the efficiency and reliability of planar chip-based single-photon sources....

  11. Few-view single photon emission computed tomography (SPECT) reconstruction based on a blurred piecewise constant object model

    DEFF Research Database (Denmark)

    Wolf, Paul A.; Jørgensen, Jakob Sauer; Schmidt, Taly G.

    2013-01-01

    A sparsity-exploiting algorithm intended for few-view Single Photon Emission Computed Tomography (SPECT) reconstruction is proposed and characterized. The algorithm models the object as piecewise constant subject to a blurring operation. To validate that the algorithm closely approximates the true...

  12. A wide spectral range single-photon avalanche diode fabricated in an advanced 180 nm CMOS technology

    NARCIS (Netherlands)

    Mandai, S.; Fishburn, M.W.; Maruyama, Y.; Charbon, E.

    2012-01-01

    We present a single-photon avalanche diode (SPAD) with a wide spectral range fabricated in an advanced 180 nm CMOS process. The realized SPAD achieves 20 % photon detection probability (PDP) for wavelengths ranging from 440 nm to 820 nm at an excess bias of 4V, with 30 % PDP at wavelengths from 520

  13. Diagnosing Alzheimer's disease in elderly, mildly demented patients: the impact of routine single photon emission computed tomography

    NARCIS (Netherlands)

    van Gool, W. A.; Walstra, G. J.; Teunisse, S.; van der Zant, F. M.; Weinstein, H. C.; van Royen, E. A.

    1995-01-01

    Based on the observation of bilateral temporoparietal hypoperfusion in Alzheimer's disease (AD), single photon emission computed tomography (SPECT) is advocated by some as a powerful diagnostic tool in the evaluation of demented patients. We studied whether routine brain SPECT in elderly, mildly

  14. Search for anomalous production of single photons at $\\sqrt{s}$ = 130 and 136 GeV

    CERN Document Server

    Adam, W; Agasi, E; Ajinenko, I; Aleksan, Roy; Alekseev, G D; Alemany, R; Allport, P P; Almehed, S; Amaldi, Ugo; Amato, S; Andreazza, A; Andrieux, M L; Antilogus, P; Apel, W D; Arnoud, Y; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Bambade, P; Barão, F; Barate, R; Barbi, M S; Barbiellini, Guido; Bardin, Dimitri Yuri; Baroncelli, A; Bärring, O; Barrio, J A; Bartl, Walter; Bates, M J; Battaglia, Marco; Baubillier, M; Baudot, J; Becks, K H; Begalli, M; Beillière, P; Belokopytov, Yu A; Belous, K S; Benvenuti, Alberto C; Berggren, M; Bertini, D; Bertrand, D; Bianchi, F; Bigi, M; Bilenky, S M; Billoir, P; Bloch, D; Blume, M; Bolognese, T; Bonesini, M; Bonivento, W; Booth, P S L; Bosio, C; Botner, O; Boudinov, E; Bouquet, B; Bourdarios, C; Bowcock, T J V; Bozzo, M; Branchini, P; Brand, K D; Brenke, T; Brenner, R A; Bricman, C; Brown, R C A; Brückman, P; Brunet, J M; Bugge, L; Buran, T; Burgsmüller, T; Buschmann, P; Buys, A; Cabrera, S; Caccia, M; Calvi, M; Camacho-Rozas, A J; Camporesi, T; Canale, V; Canepa, M; Cankocak, K; Cao, F; Carena, F; Carroll, L; Caso, Carlo; Castillo-Gimenez, M V; Cattai, A; Cavallo, F R; Chabaud, V; Charpentier, P; Chaussard, L; Chauveau, J; Checchia, P; Chelkov, G A; Chen, M; Chierici, R; Chliapnikov, P V; Chochula, P; Chorowicz, V; Cindro, V; Collins, P; Contreras, J L; Contri, R; Cortina, E; Cosme, G; Cossutti, F; Crawley, H B; Crennell, D J; Crosetti, G; Cuevas-Maestro, J; Czellar, S; Dahl-Jensen, Erik; Dahm, J; D'Almagne, B; Dam, M; Damgaard, G; Dauncey, P D; Davenport, Martyn; Da Silva, W; Defoix, C; Deghorain, A; Della Ricca, G; Delpierre, P A; Demaria, N; De Angelis, A; de Boer, Wim; De Brabandere, S; De Clercq, C; La Vaissière, C de; De Lotto, B; De Min, A; De Paula, L S; De Saint-Jean, C; Dijkstra, H; Di Ciaccio, Lucia; Djama, F; Dolbeau, J; Dönszelmann, M; Doroba, K; Dracos, M; Drees, J; Drees, K A; Dris, M; Durand, J D; Edsall, D M; Ehret, R; Eigen, G; Ekelöf, T J C; Ekspong, Gösta; Elsing, M; Engel, J P; Erzen, B; Espirito-Santo, M C; Falk, E; Fassouliotis, D; Feindt, Michael; Fenyuk, A; Ferrer, A; Fichet, S; Filippas-Tassos, A; Firestone, A; Fischer, P A; Föth, H; Fokitis, E; Fontanelli, F; Formenti, F; Franek, B J; Frenkiel, P; Fries, D E C; Frodesen, A G; Frühwirth, R; Fulda-Quenzer, F; Fuster, J A; Galloni, A; Gamba, D; Gandelman, M; García, C; García, J; Gaspar, C; Gasparini, U; Gavillet, P; Gazis, E N; Gelé, D; Gerber, J P; Gibbs, M; Gokieli, R; Golob, B; Gopal, Gian P; Gorn, L; Górski, M; Guz, Yu; Gracco, Valerio; Graziani, E; Grosdidier, G; Grzelak, K; Gumenyuk, S A; Gunnarsson, P; Günther, M; Guy, J; Hahn, F; Hahn, S; Hajduk, Z; Hallgren, A; Hamacher, K; Hao, W; Harris, F J; Hedberg, V; Henriques, R P; Hernández, J J; Herquet, P; Herr, H; Hessing, T L; Higón, E; Hilke, Hans Jürgen; Hill, T S; Holmgren, S O; Holt, P J; Holthuizen, D J; Hoorelbeke, S; Houlden, M A; Hrubec, Josef; Huet, K; Hultqvist, K; Jackson, J N; Jacobsson, R; Jalocha, P; Janik, R; Jarlskog, C; Jarlskog, G; Jarry, P; Jean-Marie, B; Johansson, E K; Jönsson, L B; Jönsson, P E; Joram, Christian; Juillot, P; Kaiser, M; Kapusta, F; Karafasoulis, K; Karlsson, M; Karvelas, E; Katsanevas, S; Katsoufis, E C; Keränen, R; Khokhlov, Yu A; Khomenko, B A; Khovanskii, N N; King, B J; Kjaer, N J; Klein, H; Klovning, A; Kluit, P M; Köne, B; Kokkinias, P; Koratzinos, M; Korcyl, K; Kostyukhin, V; Kourkoumelis, C; Kuznetsov, O; Kramer, P H; Krammer, Manfred; Kreuter, C; Kronkvist, I J; Krumshtein, Z; Krupinski, W; Kubinec, P; Kucewicz, W; Kurvinen, K L; Lacasta, C; Laktineh, I; Lamblot, S; Lamsa, J; Lanceri, L; Lane, D W; Langefeld, P; Lapin, V; Last, I; Laugier, J P; Lauhakangas, R; Leser, G; Ledroit, F; Lefébure, V; Legan, C K; Leitner, R; Lemoigne, Y; Lemonne, J; Lenzen, Georg; Lepeltier, V; Lesiak, T; Libby, J; Liko, D; Lindner, R; Lipniacka, A; Lippi, I; Lörstad, B; Loken, J G; López, J M; Loukas, D; Lutz, P; Lyons, L; MacNaughton, J N; Maehlum, G; Maio, A; Malychev, V; Marco, J; Marco, R P; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Maron, T; Martínez-Rivero, C; Martínez-Vidal, F; Martí i García, S; Matorras, F; Matteuzzi, C; Matthiae, Giorgio; Mazzucato, M; McCubbin, M L; McKay, R; McNulty, R; Medbo, J; Merk, M; Meroni, C; Meyer, S; Meyer, W T; Myagkov, A; Michelotto, M; Migliore, E; Mirabito, L; Mitaroff, Winfried A; Mjörnmark, U; Moa, T; Møller, R; Mönig, K; Monge, M R; Morettini, P; Müller, H; Mundim, L M; Murray, W J; Muryn, B; Myatt, Gerald; Naraghi, F; Navarria, Francesco Luigi; Navas, S; Nawrocki, K; Negri, P; Némécek, S; Neumann, W; Neumeister, N; Nicolaidou, R; Nielsen, B S; Nieuwenhuizen, M; Nikolaenko, V; Niss, P; Nomerotski, A; Normand, Ainsley; Novák, M; Oberschulte-Beckmann, W; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, Risto; Österberg, K; Ouraou, A; Paganini, P; Paganoni, M; Pagès, P; Palka, H; Papadopoulou, T D; Papageorgiou, K; Pape, L; Parkes, C; Parodi, F; Passeri, A; Pegoraro, M; Peralta, L; Pernegger, H; Pernicka, Manfred; Perrotta, A; Petridou, C; Petrolini, A; Petrovykh, M; Phillips, H T; Piana, G; Pierre, F; Pimenta, M; Pindo, M; Plaszczynski, S; Podobrin, O; Pol, M E; Polok, G; Poropat, P; Pozdnyakov, V; Prest, M; Privitera, P; Pukhaeva, N; Pullia, Antonio; Radojicic, D; Ragazzi, S; Rahmani, H; Rames, J; Ratoff, P N; Read, A L; Reale, M; Rebecchi, P; Redaelli, N G; Regler, Meinhard; Reid, D; Renton, P B; Resvanis, L K; Richard, F; Richardson, J; Rídky, J; Rinaudo, G; Ripp, I; Romero, A; Roncagliolo, I; Ronchese, P; Roos, L; Rosenberg, E I; Rosso, E; Roudeau, Patrick; Rovelli, T; Rückstuhl, W; Ruhlmann-Kleider, V; Ruiz, A; Rybicki, K; Saarikko, H; Sacquin, Yu; Sadovskii, A; Sahr, O; Sajot, G; Salt, J; Sánchez, J; Sannino, M; Schimmelpfennig, M; Schneider, H; Schwickerath, U; Schyns, M A E; Sciolla, G; Scuri, F; Seager, P; Sedykh, Yu; Segar, A M; Seitz, A; Sekulin, R L; Serbelloni, L; Shellard, R C; Siccama, I; Siegrist, P; Simonetti, S; Simonetto, F; Sissakian, A N; Sitár, B; Skaali, T B; Smadja, G; Smirnov, N; Smirnova, O G; Smith, G R; Sosnowski, R; Souza-Santos, D; Spassoff, Tz; Spiriti, E; Sponholz, P; Squarcia, S; Stanescu, C; Stapnes, Steinar; Stavitski, I; Stevenson, K; Stichelbaut, F; Stocchi, A; Strauss, J; Strub, R; Stugu, B; Szczekowski, M; Szeptycka, M; Tabarelli de Fatis, T; Tavernet, J P; Chikilev, O G; Thomas, J; Tilquin, A; Timmermans, J; Tkatchev, L G; Todorov, T; Todorova, S; Toet, D Z; Tomaradze, A G; Tomé, B; Tonazzo, A; Tortora, L; Tranströmer, G; Treille, D; Trischuk, W; Tristram, G; Trombini, A; Troncon, C; Tsirou, A L; Turluer, M L; Tyapkin, I A; Tyndel, M; Tzamarias, S; Überschär, B; Ullaland, O; Uvarov, V; Valenti, G; Vallazza, E; van Apeldoorn, G W; van Dam, P; Van Doninck, W K; Van Eldik, J; Vassilopoulos, N; Vegni, G; Ventura, L; Venus, W A; Verbeure, F; Verlato, M; Vertogradov, L S; Vilanova, D; Vincent, P; Vitale, L; Vlasov, E; Vodopyanov, A S; Vrba, V; Wahlen, H; Walck, C; Weierstall, M; Weilhammer, Peter; Weiser, C; Wetherell, Alan M; Wicke, D; Wickens, J H; Wielers, M; Wilkinson, G R; Williams, W S C; Winter, M; Witek, M; Woschnagg, K; Yip, K; Yushchenko, O P; Zach, F; Zaitsev, A; Zalewska-Bak, A; Zalewski, Piotr; Zavrtanik, D; Zevgolatakos, E; Zimin, N I; Zito, M; Zontar, D; Zucchelli, G C; Zumerle, G; Wiele

    1996-01-01

    This letter reports the results of the measurement of single photon production in the reaction $e^+e^- \\rightarrow \\gamma +$ invisible particles at centre-of-mass energies $\\sqrt{s}=$~130 and 136 GeV and an integrated luminosity of 5.83~pb$

  15. Measurement of single photon production in e[sup +]e[sup -] collisions near the Z[sup 0] resonance

    Energy Technology Data Exchange (ETDEWEB)

    Akers, R. (Manchester Univ. (United Kingdom). Dept. of Physics); Alexander, G.; Allison, J.; Anderson, K.J.; Arcelli, S.; Asai, S.; Astbury, A.; Axen, D.; Azuelos, G.; Ball, A.H.; Barberio, E.; Barlow, R.J.; Bartoldus, R.; Batley, J.R.; Beaudoin, G.; Beck, A.; Beck, G.A.; Becker, J.; Beeston, C.; Behnke, T.; Bell, K.W.; Bella, G.; Bentkowski, P.; Bentvelsen, S.; Berlich, P.; Bethke, S.; Biebel, O.; Bloodworth, I.J.; Bock, P.; Bosch, H.M.; Boutemeur, M.; Braibant, S.; Bright-Thomas, P.; Brown, R.M.; Buijs, A.; Burckhart, H.J.; Burgard, C.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlesworth, C.; Charlton, D.G.; Chu, S.L.; Clarke, P.E.L.; Clayton, J.C.; Clowes, S.G.; Cohen, I.; Conboy, J.E.; Coupland, M.; Cuffiani, M.; Dado, S.; Dallapiccola, C.; Darling, C.; Dallavalle, G.M.; Jong, S. de; Deng, H.; Dittmar, M.; Dixit, M.S.; Couto e Silva, E. do; Duchovni, E.; Duboscq, J.E.; Duckeck, G.; Duerdoth, I.P.; Dunwoody, U.C.; Elcombe, P.A.; Estabrooks, P.G.; Et; OPAL Collaboration

    1995-01-01

    A measurement of the single photon production cross-section is presented based on a data-sample of 40.5 pb[sup -1] collected with the OPAL detector at centre-of-mass energies within 3 GeV of the Z[sup 0] mass. Single photon events arise from initial state radiation and the production of an ''invisible'' final state consisting of neutrinos or possibly particles such as sneutrinos or photinos. The single photon topology is also sensitive to new Z[sup 0] decays such as Z[sup 0] [yields] anti [nu][nu][sup *] [yields] anti [nu][nu][gamma] or Z[sup 0] [yields] [gamma]X, X [yields] invisible particles. A total of 447 single photon candidates were observed with energy exceeding 1.75 GeV in the polar angle region vertical stroke cos [theta]vertical stroke < 0.7. The estimated background from processes with visible reaction products, mainly e[sup +]e[sup -] [yields] e[sup +]e[sup -][gamma], is 37 [+-] 6 events. Interpreting the cross-sections as being solely due to Z[sup 0] decay to invisible particles and the expected W-contributions, the Z[sup 0] invisible width is determined to be 539 [+-] 26 [+-] 17 MeV corresponding to N[sub [nu

  16. Exercise echocardiography and single photon emission computed tomography in patients with left anterior descending coronary artery stenosis

    NARCIS (Netherlands)

    A. Salustri (Alessandro); M. Pozzoli (M.); B. Ilmer; W.R.M. Hermans (Walter); A.E.M. Reijs (Ambroos); J.H.C. Reiber (Johan); J.R.T.C. Roelandt (Jos); P.M. Fioretti (Paolo)

    1992-01-01

    textabstractTo compare the diagnostic value of exercise echocardiography and perfusion single photon emission computed tomography (SPECT) in the detection of the presence and the severity of coronary artery disease, we studied 21 patients with isolated stenosis of different degree of the left

  17. Progress Toward Single-Photon-Level Nonlinear Optics in Crystalline Microcavities

    Science.gov (United States)

    Kowligy, Abijith S.

    Over the last two decades, the emergence of quantum information science has uncovered many practical applications in areas such as communications, imaging, and sensing where harnessing quantum features of Nature provides tremendous benefits over existing methods exploiting classical physical phenomena. In this effort, one of the frontiers of research has been to identify and utilize quantum phenomena that are not susceptible to environmental and parasitic noise processes. Quantum photonics has been at the forefront of these studies because it allows room-temperature access to its inherently quantum-mechanical features, and allows leveraging the mature telecommunication industry. Accompanying the weak environmental influence, however, are also weak optical nonlinearities. Efficient nonlinear optical interactions are indispensible for many of the existing protocols for quantum optical computation and communication, e.g. high-fidelity entangling quantum logic gates rely on large nonlinear responses at the one- or few-photon-level. While this has been addressed to a great extent by interfacing photons with single quantum emitters and cold atomic gases, scalability has remained elusive. In this work, we identify the macroscopic second-order nonlinear polarization as a robust platform to address this challenge, and utilize the recent advances in the burgeoning field of optical microcavities to enhance this nonlinear response. In particular, we show theoretically that by using the quantum Zeno effect, low-noise, single-photon-level optical nonlinearities can be realized in lithium niobate whispering-gallery-mode microcavities, and present experimental progress toward this goal. Using the measured strength of the second-order nonlinear response in lithium niobate, we modeled the nonlinear system in the strong coupling regime using the Schrodinger picture framework and theoretically demonstrated that the single-photon-level operation can be observed for cavity lifetimes in

  18. Custom single-photon avalanche diode with integrated front-end for parallel photon timing applications

    Science.gov (United States)

    Cammi, C.; Panzeri, F.; Gulinatti, A.; Rech, I.; Ghioni, M.

    2012-03-01

    Emerged as a solid state alternative to photo multiplier tubes (PMTs), single-photon avalanche diodes (SPADs) are nowadays widely used in the field of single-photon timing applications. Custom technology SPADs assure remarkable performance, in particular a 10 counts/s dark count rate (DCR) at low temperature, a high photon detection efficiency (PDE) with a 50% peak at 550 nm and a 30 ps (full width at half maximum, FWHM) temporal resolution, even with large area devices, have been obtained. Over the past few years, the birth of novel techniques of analysis has led to the parallelization of the measurement systems and to a consequent increasing demand for the development of monolithic arrays of detectors. Unfortunately, the implementation of a multidimensional system is a challenging task from the electrical point of view; in particular, the avalanche current pick-up circuit, used to obtain the previously reported performance, has to be modified in order to enable high parallel temporal resolution, while minimizing the electrical crosstalk probability between channels. In the past, the problem has been solved by integrating the front-end electronics next to the photodetector, in order to reduce the parasitic capacitances and consequently the filtering action on the current signal of the SPAD, leading to an improvement of the timing jitter at higher threshold. This solution has been implemented by using standard complementary metal-oxide-semiconductor (CMOS) technologies, which, however, do not allow a complete control on the SPAD structure; for this reason the intrinsic performance of CMOS SPADs, such as DCR, PDE, and afterpulsing probability, are worse than those attainable with custom detectors. In this paper, we propose a pixel architecture, which enables the development of custom SPAD arrays in which every channel maintains the performance of the best single photodetector. The system relies on the integration of the timing signal pick-up circuit next to the

  19. SPADAS: a high-speed 3D single-photon camera for advanced driver assistance systems

    Science.gov (United States)

    Bronzi, D.; Zou, Y.; Bellisai, S.; Villa, F.; Tisa, S.; Tosi, A.; Zappa, F.

    2015-02-01

    Advanced Driver Assistance Systems (ADAS) are the most advanced technologies to fight road accidents. Within ADAS, an important role is played by radar- and lidar-based sensors, which are mostly employed for collision avoidance and adaptive cruise control. Nonetheless, they have a narrow field-of-view and a limited ability to detect and differentiate objects. Standard camera-based technologies (e.g. stereovision) could balance these weaknesses, but they are currently not able to fulfill all automotive requirements (distance range, accuracy, acquisition speed, and frame-rate). To this purpose, we developed an automotive-oriented CMOS single-photon camera for optical 3D ranging based on indirect time-of-flight (iTOF) measurements. Imagers based on Single-photon avalanche diode (SPAD) arrays offer higher sensitivity with respect to CCD/CMOS rangefinders, have inherent better time resolution, higher accuracy and better linearity. Moreover, iTOF requires neither high bandwidth electronics nor short-pulsed lasers, hence allowing the development of cost-effective systems. The CMOS SPAD sensor is based on 64 × 32 pixels, each able to process both 2D intensity-data and 3D depth-ranging information, with background suppression. Pixel-level memories allow fully parallel imaging and prevents motion artefacts (skew, wobble, motion blur) and partial exposure effects, which otherwise would hinder the detection of fast moving objects. The camera is housed in an aluminum case supporting a 12 mm F/1.4 C-mount imaging lens, with a 40°×20° field-of-view. The whole system is very rugged and compact and a perfect solution for vehicle's cockpit, with dimensions of 80 mm × 45 mm × 70 mm, and less that 1 W consumption. To provide the required optical power (1.5 W, eye safe) and to allow fast (up to 25 MHz) modulation of the active illumination, we developed a modular laser source, based on five laser driver cards, with three 808 nm lasers each. We present the full characterization of

  20. Single photon sources using oxide apertured micropillars with integrated electrical control for novel functionalities

    Science.gov (United States)

    Stoltz, Nicholas G.

    The goal of this thesis is to apply the oxide apertured vertical cavity laser structure in order to explore quantum dot-microcavity coupling for the development of novel single photon sources (SPS). Optical microcavities combined with active emitters provide an opportunity to study the light matter interaction on a fundamental level. Edward Purcell first theorized in 1947 that the spontaneous emission (SE) rate of an optical emitter could be modified in the presence of an optical cavity. As semiconductor microcavity technology has advanced many optoelectronic devices have benefited from the increased SE rates predicted by the Purcell effect. The development of quantum emitters on an integrated semiconductor platform in the form of semiconductor self-assembled quantum dots (QDs) has expanded applications in the field. Coupling atomic emitters to optical microcavities in the solid state allows for the study of cavity quantum electrodynamics and the fabrication single photon (SP) devices. Optoelectronic devices providing non-classical light states have a broad range of applications in quantum information science, including quantum key distribution systems, quantum lithography, and quantum computing. Here, the oxide apertured micropillar approach demonstrates high quality microcavities with cavity quality factors up to 50,000 and measured Purcell enhancements of 10. In addition the inherent advantages provided by the oxide apertured micropillar, specifically high collection efficiency, have produced SPSs with record high SP rates and quantum efficiencies representing a six-fold improvement over reported values. In addition we have developed and integrated a scheme allowing for on-chip electrical control of SP devices for the implementation of SPSs with novel functionalities. The active electrical control of QD charge state has allowed for the elimination of dark states which severely limit SP rates and efficiencies. The active electrical tuning of QD emission energy

  1. Ultrabright and efficient single-photon generation based on nitrogen-vacancy centres in nanodiamonds on a solid immersion lens

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Tim; Gaedeke, Friedemann; Banholzer, Moritz Julian; Benson, Oliver, E-mail: tim.schroeder@physik.hu-berlin.de [Humboldt-Universitaet zu Berlin, Institut fuer Physik, AG Nano Optics Newtonstrasse 15, 12489 Berlin (Germany)

    2011-05-15

    Single photons are fundamental elements for quantum information technologies such as quantum cryptography, quantum information storage and optical quantum computing. Colour centres in diamond have proven to be stable single-photon sources and thus essential components for reliable and integrated quantum information technology. A key requirement for such applications is a large photon flux and a high efficiency. Paying tribute to various attempts to maximize the single-photon flux, we show that collection efficiencies of photons from colour centres can be increased with a rather simple experimental setup. To do so, we spin-coated nanodiamonds containing single nitrogen-vacancy (N-V) colour centres on the flat surface of a ZrO{sub 2} solid immersion lens. We found stable single-photon count rates of up to 853 kcts s{sup -1} at saturation under continuous wave excitation while having access to more than 100 defect centres with count rates from 400 to 500 kcts s{sup -1}. For a blinking defect centre, we found count rates up to 2.4 Mcts s{sup -1} for time intervals of several tens of seconds. It seems to be a general feature that very high rates are accompanied by blinking behaviour. The overall collection efficiency of our setup of up to 4.2% is the highest yet reported for N-V defect centres in diamond. Under pulsed excitation of a stable emitter of 10 MHz, 2.2% of all pulses caused a click on the detector adding to 221 kcts s{sup -1} thus, opening the way towards diamond-based on-demand single-photon sources for quantum applications.

  2. Single photon emission computed tomography in the diagnosis of Alzheimer's disease

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Asano, Tetsuichi; Abe, Shin'e; Arai, Hisayuki; Iwamoto, Toshihiko; Takasaki, Masaru; Shindo, Hiroaki; Abe, Kimihiko

    1997-01-01

    Studies with single photon emission computed tomography (SPECT) have shown temporoparietal (TP) hypoperfusion in patients with Alzheimer's disease (AD). We evaluated the utility of this findings in the diagnosis of AD. SPECT images with 123 I-iodoamphetamine were analyzed qualitatively by a rater without knowledge of the subject's clinical status. Sixty-seven of 302 consecutive patients were judged as having TP hypoperfusion by SPECT imaging. This perfusion pattern was observed in 44 of 51 patients with AD, in 5 with mixed dementia, 8 with cerebrovascular disease (including 5 with dementia), 4 with Parkinson's disease (including 2 with dementia), 1 with normal pressure hydrocephalus, 1 with slowly progressive aphasia, 1 with progressive autonomic failure, 2 with age-associated memory impairment, and 1 with unclassified dementia. The sensitivity for AD was 86.3% (44 of 51 AD), and the specificity was 91.2% (229 of 251 non-AD). Next, we looked for differences in perfusion images between patients with AD and without AD. Some patients without AD had additional hypoperfusion beyond TP areas: deep gray matter hypoperfusion and diffuse frontal hypoperfusion, which could be used to differentiate them from the patients with AD. Others could not be distinguished from patients with AD by their perfusion pattern. Although patients with other cerebral disorders occasionally have TP hypoperfusion, this finding makes the diagnosis of AD very likely. (author)

  3. Single photon emission computed tomography in the diagnosis of Alzheimer`s disease

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Asano, Tetsuichi; Abe, Shin`e; Arai, Hisayuki; Iwamoto, Toshihiko; Takasaki, Masaru; Shindo, Hiroaki; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    1997-06-01

    Studies with single photon emission computed tomography (SPECT) have shown temporoparietal (TP) hypoperfusion in patients with Alzheimer`s disease (AD). We evaluated the utility of this findings in the diagnosis of AD. SPECT images with {sup 123}I-iodoamphetamine were analyzed qualitatively by a rater without knowledge of the subject`s clinical status. Sixty-seven of 302 consecutive patients were judged as having TP hypoperfusion by SPECT imaging. This perfusion pattern was observed in 44 of 51 patients with AD, in 5 with mixed dementia, 8 with cerebrovascular disease (including 5 with dementia), 4 with Parkinson`s disease (including 2 with dementia), 1 with normal pressure hydrocephalus, 1 with slowly progressive aphasia, 1 with progressive autonomic failure, 2 with age-associated memory impairment, and 1 with unclassified dementia. The sensitivity for AD was 86.3% (44 of 51 AD), and the specificity was 91.2% (229 of 251 non-AD). Next, we looked for differences in perfusion images between patients with AD and without AD. Some patients without AD had additional hypoperfusion beyond TP areas: deep gray matter hypoperfusion and diffuse frontal hypoperfusion, which could be used to differentiate them from the patients with AD. Others could not be distinguished from patients with AD by their perfusion pattern. Although patients with other cerebral disorders occasionally have TP hypoperfusion, this finding makes the diagnosis of AD very likely. (author)

  4. Single-photon detector operating under extremely high background photon flux conditions

    International Nuclear Information System (INIS)

    Prochazka, Ivan; Sopko, Bruno; Blazej, Josef

    2009-01-01

    We are reporting our results in research and development in the field of avalanche semiconductor single-photon detectors and their application. Our goal was a development of a solid-state photon-counting detector capable of high-precision photon arrival time tagging in extremely harsh operating conditions. The background photon flux exceeding 10 9 photons per second hitting the detector active area should not avoid the useful signal detection and recognition on the signal level of units of photons per second. This is background photon flux about two orders of magnitude higher than what the conventional solid-state photon counters accept. The detection timing resolution should be better than 100 ps and the delay stability should be on picosecond level. We have developed and tested the active quenched and gated avalanche structure on silicon providing the required features in connection with the K14 detection chips. The detector is capable of gated operation under the conditions of background photon flux of 5x10 9 photons per second. The operational detector tolerates long term exposures to the input photon flux exceeding 10 15 photons (>1 mW) per second without damage.

  5. Single-photon-sensitive linear-mode APD ladar receiver developments

    Science.gov (United States)

    Williams, George M.; Compton, Madison A.; Huntington, Andrew S.

    2008-04-01

    New measurements are presented for multi-stage InGaAs avalanche photodiodes (APDs) which have the potential to perform GHz-rate single photon counting in linear mode. No increase in dark current was measured for an 11-device sample of 5-stage APDs following 717 hours of accelerated aging under bias at 50°C, during an initial lifetime study. Impulse response times of 0.45 ns, 0.9 ns, and 1.1 ns were measured directly for 6-, 8-, and 10-stage APDs, respectively, operated at a nominal gain of M=10. To assess the suitability of the technology for a NASA optical communications application, separate samples of 5-stage APDs were irradiated by 1- and 2-MeV protons at the University of Washington's Center for Experimental Nuclear Physics and Astrophysics (UW CENPA) and by 63.5-MeV protons at the University of California Davis, Crocker Nuclear Laboratory (UCD CNL). Good agreement between calculated non-ionizing energy loss (NIEL) and observed damage was found for the low-energy protons at fluences of 10 10 and 10 11 cm -2. A NIEL calculation successfully predicted the damage observed following a 5×10 10 cm -2 dose of 63.5-MeV protons by extrapolating from 2 MeV data, which suggests that displacement damage is the dominant mechanism.

  6. Gated single photon emission computer tomography for the detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Pena Q, Yamile; Coca P, Marco Antonio; Batista C, Juan Felipe; Fernandez-Britto, Jose; Quesada P, Rodobaldo; Pena C; Andria

    2009-01-01

    Background: Asymptomatic patients with severe coronary atherosclerosis may have a normal resting electrocardiogram and stress test. Aim: To assess the yield of Gated Single Photon Emission Computer Tomography (SPECT) for the screening of silent myocardial ischemia in type 2 diabetic patients. Material and methods: Electrocardiogram, stress test and gated-SPECT were performed on 102 type 2 diabetic patients aged 60 ± 8 years without cardiovascular symptoms. All subjects were also subjected to a coronary angiography, whose results were used as gold standard. Results: Gated-SPECT showed myocardial ischemia on 26.5% of studied patients. The sensibility, specificity, accuracy, positive predictive value and negative predictive value were 92.3%, 96%, 95%, 88.8%, 97.3%, respectively. In four and six patients ischemia was detected on resting electrocardiogram and stress test, respectively. Eighty percent of patients with doubtful resting electrocardiogram results and 70% with a doubtful stress test had a silent myocardial ischemia detected by gated-SPECT. There was a good agreement between the results of gated-SPECT and coronary angiography (k =0.873). Conclusions: Gated-SPECT was an useful tool for the screening of silent myocardial ischemia

  7. Improvement on image quality of single photon ECT with converging collimator system

    International Nuclear Information System (INIS)

    Murayama, Hideo; Nohara, Norimasa; Tanaka, Eiichi

    1986-01-01

    Single photon emission computed tomography (SPECT) with converging collimator system was proposed to improve quality of reconstructed images. The collimator system was designed to enhance sensitivity at the center region of field-of-view, where the probability photons escape the attenuating medium is smaller than at the off-center region. In order to evaluate efficiency of the improvement on image quality, the weighting function of projection, which is defined as relative sensitivity to the average on the lateral sampling of projection, was adopted to the image reconstruction algorithm of Radial Post Correction method. Statistical mean square noise in a reconstructed image was formulated in this method. Simulation studies using typical weighting function showed that center-enhanced weighting function brings effective improvement on image quality, especially, at the center region of cold area surrounded by annularly distributed activity. A new SPECT system was proposed as one example of the converging collimator systems. The system is composed of four gamma cameras with four fan-beam collimators, which have different focal distances one another. Simple simulation studies showed that the proposed system has reasonable center-enhanced weighting function, and the image quality based on the proposed system was fairly improved as compared with one based on uniform weighting function at the center region of the field-of-view. (author)

  8. High-Dimensional Single-Photon Quantum Gates: Concepts and Experiments

    Science.gov (United States)

    Babazadeh, Amin; Erhard, Manuel; Wang, Feiran; Malik, Mehul; Nouroozi, Rahman; Krenn, Mario; Zeilinger, Anton

    2017-11-01

    Transformations on quantum states form a basic building block of every quantum information system. From photonic polarization to two-level atoms, complete sets of quantum gates for a variety of qubit systems are well known. For multilevel quantum systems beyond qubits, the situation is more challenging. The orbital angular momentum modes of photons comprise one such high-dimensional system for which generation and measurement techniques are well studied. However, arbitrary transformations for such quantum states are not known. Here we experimentally demonstrate a four-dimensional generalization of the Pauli X gate and all of its integer powers on single photons carrying orbital angular momentum. Together with the well-known Z gate, this forms the first complete set of high-dimensional quantum gates implemented experimentally. The concept of the X gate is based on independent access to quantum states with different parities and can thus be generalized to other photonic degrees of freedom and potentially also to other quantum systems.

  9. Single-photon emission computed tomographic findings and motor neuron signs in amyotrophic lateral sclerosis

    International Nuclear Information System (INIS)

    Terao, Shin-ichi; Sobue, Gen; Higashi, Naoki; Takahashi, Masahiko; Suga, Hidemichi; Mitsuma, Terunori

    1995-01-01

    123 I-amphetamine-single photon emission computed tomography (SPECT) was performed on 16 patients with amyotrophic lateral sclerosis (ALS) to investigate the correlation between regional cerebral blood flow (rCBF) and upper motor neuron signs. Significant decreased blood flow less than 2 SDs below the mean of controls was observed in the frontal lobe in 4 patients (25%) and in the frontoparietal lobe including the cortical motor area in 4 patients, respectively. The severity of extermity muscular weakness was significantly correlate with decrease in blood flow through the frontal lobe (p<0.05) and through the frontoparietal lobe (p<0.001). A significant correlation was also noted to exist between the severity of bulbar paralysis and decrease in blood flow through the frontoparietal lobe. No correlation, however, was observed between rCBF and severity of spasticity, presence or absence of Babinski's sign and the duration of illness. Although muscular weakness in the limbs and bulbar paralysis are not pure upper motor neuron signs, the observed reduction in blood flow through the frontal or frontoparietal lobes appears to reflect extensive progression of functional or organic lesions of cortical neurons including the motor area. (author)

  10. Musicogenic epilepsy: review of the literature and case report with ictal single photon emission computed tomography.

    Science.gov (United States)

    Wieser, H G; Hungerbühler, H; Siegel, A M; Buck, A

    1997-02-01

    We report a case of musicogenic epilepsy with ictal single photon emission computed tomography (SPECT) study and discuss the findings of this patient in the context of 76 cases with musicogenic epilepsy described in the literature and seven other cases followed in Zurich. We analyzed the 83 patients according to the precipitating musical factors, type of epilepsy, presumed localization of seizure onset, and demographic data. Fourteen of 83 patients (17%) had seizures triggered exclusively by music. At time of examination, music was the only known precipitating stimulus in 65 of 83 patients (78%). Various characteristics of the musical stimulus were significant, e.g., musical category, familiarity, and instruments. Musicogenic epilepsy is a particular form of epilepsy with a strong correlation to the temporal lobe and a right-sided preponderance. A high musial standard might predispose for musicogenic epilepsy. Moreover, the majority of cases do not fall into the category of a strictly defined "reflex epilepsy," but appear to depend on the indermediary of a certain emotional reaction mediated through limbic mesial temporal lobe structures.

  11. Quantum interference of single photons from two remote nitrogen-vacancy centers in diamond

    Science.gov (United States)

    Goldman, Michael; Sipahigil, Alp; Togan, Emre; Chu, Yiwen; Markham, Mark; Twitchen, Daniel; Zibrov, Alexander; Kubanek, Alexander; Lukin, Mikhail

    2012-06-01

    The interference of two identical photons impinging on a beam splitter leads to perfect photon coalescence where both photons leave through the same output port. This effect, known as Hong-Ou-Mandel (HOM) interference, can be used to characterize the properties of quantum emitters with high accuracy. This is a particularly useful tool for quantum emitters embedded in a solid state matrix because their internal properties, unlike those of atoms in free space, differ substantially from emitter to emitter due to strong interactions with the environment. HOM interference can also be used to generate optically mediated entanglement between two remote quantum emitters, a crucial step toward the development of long-distance quantum communication and scalable quantum computation architectures. Here, we demonstrate this interference effect with single photons emitted from two single Nitrogen-Vacancy (NV) centers in diamond samples that are spatially separated by 2 meters [1]. The detuning of the photons can be tuned by applying a DC electric field to one NV center. We discuss current efforts toward optical entanglement of the two NV centers. [4pt] [1] A. Sipahigil, M. L. Goldman, E. Togan, Y. Chu, M. Markham, D. J. Twitchen, A. S. Zibrov, A. Kubanek, and M. D. Lukin, arXiv:1112.3975v1.

  12. Comparison of Ga-67 planar imaging and single photon emission computed tomography in malignant chest disease

    International Nuclear Information System (INIS)

    Tumeh, S.S.; Rosenthal, D.; Kaplan, W.D.; English, R.E.; Holman, B.L.

    1985-01-01

    To determine the value of Ga-67 single photon emission computed tomography (SPECT) in patients (pts) with malignant chest disease, the authors compared Ga-67 planar scans (ps) and SPECT with the medical records in twenty-five consecutive patients. Twenty-three examinations were performed on 17 pts with Hodgkin's disease (HD) and three pts with non-Hodgkin's lymphoma. Five examinations were performed on 5 pts with bronchogenic carcinoma (BC). The two modalities were evaluated for (1) presence or absence of disease, (2) number of foci of abnormal uptake and (3) extent of disease. In pts with lymphoma, SPECT defined the extent of disease better than planar imaging in eight examinations; it demonstrated para-cardial involvement in one pt, separated hilar from mediastinal disease in 4, and demonstrated posterior mediastinal disease in 3. SPECT clarified suspicious foci on planar images in seven examinations, correctly ruled out disease in two pts with equivocal planar images and did not exchange planar image findings in six examinations. In pts with bronchogenic carcinoma, both medalities correctly ruled out mediastinal involvement in three pts. SPECT detected mediastinal lymph node involvement in one pt with equivocal planar images. Both SPECT and planar imaging missed direct tumor extension to the mediastinum in one pt. They conclude that Ga-67 with SPECT is better than planar images for staging of chest lymphoma and BC. Since it defines different lymph node groups it carries a good potential for staging as well as follow up of those pts

  13. Bone mineral content measurement in small infants by single-photon absorptiometry: current methodologic issues

    Energy Technology Data Exchange (ETDEWEB)

    Steichen, J.J.; Asch, P.A.; Tsang, R.C.

    1988-07-01

    Single-photon absorptiometry (SPA), developed in 1963 and adapted for infants by Steichen et al. in 1976, is an important tool to quantitate bone mineralization in infants. Studies of infants in which SPA was used include studies of fetal bone mineralization and postnatal bone mineralization in very low birth weight infants. The SPA technique has also been used as a research tool to investigate longitudinal bone mineralization and to study the effect of nutrition and disease processes such as rickets or osteopenia of prematurity. At present, it has little direct clinical application for diagnosing bone disease in single patients. The bones most often used to measure bone mineral content (BMC) are the radius, the ulna, and, less often, the humerus. The radius appears to be preferred as a suitable bone to measure BMC in infants. It is easily accessible; anatomic reference points are easily palpated and have a constant relationship to the radial mid-shaft site; soft tissue does not affect either palpation of anatomic reference points or BMC quantitation in vivo. The peripheral location of the radius minimizes body radiation exposure. Trabecular and cortical bone can be measured separately. Extensive background studies exist on radial BMC in small infants. Most important, the radius has a relatively long zone of constant BMC. Finally, SPA for BMC in the radius has a high degree of precision and accuracy. 61 references.

  14. Single photon emission computed tomography (SPECT) in seizure disorders in childhood

    International Nuclear Information System (INIS)

    Vles, J.S.H.; Demandt, E.; Ceulemans, B.; de Roo, M.; Casaer, P.J.M.

    1990-01-01

    In 38 children with partial seizures, the EEG, CT and NMR findings were compared to the results obtained with Tc99m HMPAO single photon emission computed tomography (SPECT) in order to determine whether SPECT is a useful adjunct to EEG, CT and NMR in this age group. In 3 out of 7 patients with a normal EEG, SPECT showed focal abnormalities. Nine patients whose EEGs did not show adequate lateralization had an abnormal SPECT which revealed a focus. In 14 out of 21 patients with a normal CT, SPECT showed focal changes in 13 patients and diffuse changes in the other one. In 7 out of 12 patients with a normal NMR, SPECT showed focal abnormalities. Although clinical history and a careful description of the seizures are the most valuable information in partial seizure disorders, SPECT imaging gives valuable additional information, which might target treatment. SPECT was superior to CT and NMR with respect to the depiction of some kind of abnormality. (author)

  15. Pinhole single-photon emission tomography reconstruction based on median root prior

    International Nuclear Information System (INIS)

    Sohlberg, Antti; Kuikka, Jyrki T.; Ruotsalainen, Ulla

    2003-01-01

    The maximum likelihood expectation maximisation (ML-EM) algorithm can be used to reduce reconstruction artefacts produced by filtered backprojection (FBP) methods in pinhole single-photon emission tomography (SPET). However, ML-EM suffers from noise propagation along iterations, which leads to quantitatively unpleasant reconstruction results. To avoid this increase in noise, the median root prior (MRP) algorithm for pinhole SPET was implemented. Projection data of a line source and Picker's thyroid phantom were collected using a single-head gamma camera with a pinhole collimator. MRP was added to existing pinhole ML-EM reconstruction algorithm and the phantom studies were reconstructed using MRP, ML-EM and FBP for comparison. Coefficients of variation, contrasts and full-widths at half-maximum were calculated and showed a clear reduction in noise without significant loss of resolution or decrease in contrast when MRP was applied. MRP also produced visually pleasing images even with high iteration numbers, free of the checkerboard-type noise patterns which are typical of ML-EM images. (orig.)

  16. Restoration filtering based on projection power spectrum for single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Kubo, Naoki

    1995-01-01

    To improve the quality of single-photon emission computed tomographic (SPECT) images, a restoration filter has been developed. This filter was designed according to practical 'least squares filter' theory. It is necessary to know the object power spectrum and the noise power spectrum. The power spectrum is estimated from the power spectrum of a projection, when the high-frequency power spectrum of a projection is adequately approximated as a polynomial exponential expression. A study of the restoration with the filter based on a projection power spectrum was conducted, and compared with that of the 'Butterworth' filtering method (cut-off frequency of 0.15 cycles/pixel), and 'Wiener' filtering (signal-to-noise power spectrum ratio was a constant). Normalized mean-squared errors (NMSE) of the phantom, two line sources located in a 99m Tc filled cylinder, were used. NMSE of the 'Butterworth' filter, 'Wiener' filter, and filtering based on a power spectrum were 0.77, 0.83, and 0.76 respectively. Clinically, brain SPECT images utilizing this new restoration filter improved the contrast. Thus, this filter may be useful in diagnosis of SPECT images. (author)

  17. Astigmatic single photon emission computed tomography imaging with a displaced center of rotation

    International Nuclear Information System (INIS)

    Wang, H.; Smith, M.F.; Stone, C.D.; Jaszczak, R.J.

    1998-01-01

    A filtered backprojection algorithm is developed for single photon emission computed tomography (SPECT) imaging with an astigmatic collimator having a displaced center of rotation. The astigmatic collimator has two perpendicular focal lines, one that is parallel to the axis of rotation of the gamma camera and one that is perpendicular to this axis. Using SPECT simulations of projection data from a hot rod phantom and point source arrays, it is found that a lack of incorporation of the mechanical shift in the reconstruction algorithm causes errors and artifacts in reconstructed SPECT images. The collimator and acquisition parameters in the astigmatic reconstruction formula, which include focal lengths, radius of rotation, and mechanical shifts, are often partly unknown and can be determined using the projections of a point source at various projection angles. The accurate determination of these parameters by a least squares fitting technique using projection data from numerically simulated SPECT acquisitions is studied. These studies show that the accuracy of parameter determination is improved as the distance between the point source and the axis of rotation of the gamma camera is increased. The focal length to the focal line perpendicular to the axis of rotation is determined more accurately than the focal length to the focal line parallel to this axis. copyright 1998 American Association of Physicists in Medicine

  18. Thallium-201 imaging of brain tumors using single photon emission CT

    Energy Technology Data Exchange (ETDEWEB)

    Araki, Yuzo; Imao, Yukinori; Hirata, Toshifumi; Andoh, Takashi; Sakai, Noboru; Yamada, Hiromu (Gifu Univ. (Japan). Faculty of Medicine)

    1989-11-01

    Single photon emission CT using thallium-201 chloride, injected intravenously, was performed on 28 cases of cerebral lesions, among which were 16 gliomas, 2 meningiomas, 5 other brain tumors, 3 metastatic brain tumors and 2 cerebral radiation necroses. The degree of thallium-201 accumulation was evaluated by a new method called the thallium index (TLI); that is, TLI was expressed as (T-C)/C (T and C indicate relative counts in a pixel of a lesion and in non-affected normal brain tissue, respectively). Thallium-201 accumulation occurred in 86% (24) of the evaluated cases. In general, there was a tendency in high-grade or recurrent gliomas, as well as in metastatic brain tumors for the TLI values to be high. Moreover, high TLI values were noticed in cases of meningioma, radiation necrosis of cerebellum and in cases involving subacute stages of cerebral infarction. It is particularly noteworthy that the meningioma TLI values were about two times higher than those of the glioblastomas. The CT contrast-enhancement of lesions was clearly correlated with the TLI values, and the relationship between the TLI values and the number of vessels observed microscopically in the specimen was statistically significant. From the above results, it was concluded that thallium-201 accumulation in lesions might be strongly influenced by the development of vascularity in lesions, and/or the interference with the blood brain barrier due to the tumor itself. However, this malignancy diagnostic method is probably limited to the diagnosis of glioma. (author).

  19. The effect of scattering on single photon transmission of optical angular momentum

    International Nuclear Information System (INIS)

    Andrews, D L

    2011-01-01

    Schemes for the communication and registration of optical angular momentum depend on the fidelity of transmission between optical system components. It is known that electron spin can be faithfully relayed between exciton states in quantum dots; it has also been shown by several theoretical and experimental studies that the use of beams conveying orbital angular momentum can significantly extend the density and efficiency of such information transfer. However, it remains unclear to what extent the operation of such a concept at the single photon level is practicable—especially where this involves optical propagation through a material system, in which forward scattering events can intervene. The possibility of transmitting and decoding angular momentum over nanoscale distances itself raises other important issues associated with near-field interrogation. This paper provides a framework to address these and related issues. A quantum electrodynamical representation is constructed and used to pursue the consequences of individual photons, from a Laguerre–Gaussian beam, undergoing single and multiple scattering events in the course of propagation. In this context, issues concerning orbital angular momentum conservation, and its possible compromise, are tackled by identifying the relevant components of the electromagnetic scattering and coupling tensors, using an irreducible Cartesian basis. The physical interpretation broadly supports the fidelity of quantum information transmission, but it also identifies potential limitations of principle

  20. The effect of scattering on single photon transmission of optical angular momentum

    Science.gov (United States)

    Andrews, D. L.

    2011-06-01

    Schemes for the communication and registration of optical angular momentum depend on the fidelity of transmission between optical system components. It is known that electron spin can be faithfully relayed between exciton states in quantum dots; it has also been shown by several theoretical and experimental studies that the use of beams conveying orbital angular momentum can significantly extend the density and efficiency of such information transfer. However, it remains unclear to what extent the operation of such a concept at the single photon level is practicable—especially where this involves optical propagation through a material system, in which forward scattering events can intervene. The possibility of transmitting and decoding angular momentum over nanoscale distances itself raises other important issues associated with near-field interrogation. This paper provides a framework to address these and related issues. A quantum electrodynamical representation is constructed and used to pursue the consequences of individual photons, from a Laguerre-Gaussian beam, undergoing single and multiple scattering events in the course of propagation. In this context, issues concerning orbital angular momentum conservation, and its possible compromise, are tackled by identifying the relevant components of the electromagnetic scattering and coupling tensors, using an irreducible Cartesian basis. The physical interpretation broadly supports the fidelity of quantum information transmission, but it also identifies potential limitations of principle.

  1. Characterisation of a single photon counting pixel system for imaging of low-contrast objects

    CERN Document Server

    Mikulec, B; Dipasquale, G; Schwarz, C; Watt, J

    2001-01-01

    In the framework of the Medipix collaboration the PCC, a single photon counting pixel chip, has been developed with the aim of improving the contrast resolution in medical imaging applications. The PCC consists of a matrix of 64x64 square pixels with 170 mm side length, each pixel comprising a 15 bit counter and a pulse height discriminator. The chip has been bump bonded to equally segmented 200 mm thick SI-LEC GaAs detectors showing a very high absorption energy for X-rays used in diagnostics. An absolute calibration of the system with a radioactive source and a synchrotron beam are described resulting in the value of the test input capacitance of ~24.7 fF. Using this value a full characterisation of the system from electrical measurements is presented. The entire system can reach a minimum threshold of ~2100 e- with ~250e- rms noise. One of the characteristics of the PCC is the possibility to adjust the thresholds of all pixels on a pixel-by-pixel basis with 3-bit precision. The threshold distribution after...

  2. A Readout Chip for a 64 x 64 Pixel Matrix with 15-bit Single Photon Counting

    CERN Document Server

    Campbell, M; Meddeler, G; Pernigotti, E; Snoeys, W

    1998-01-01

    A single Photon Counting pixel detector readout Chip (PCC) has been derived from previous work in the CERN RD19 collaboration for particle physics tracking devices, recently developed for high energy physics experiments. The readout chip is a 64 x 64 matrix of identical 170mm x 170mm cells. It is to be bump-bonded to an equally segmented 1 cm2 matrix of semiconductor sensors, e.g. Si or GaAs. Each readout cell comprises a preamplifier, a discriminator and a 15-bit counter. The input noise is 170 e- rms. At the lowest nominal threshold of 1 400 e- (5.1 keV in Si) the cells exhibit a threshold di stribution with a spread before adjustment of 350 e- rms. Each cell has a 5-bit register which allows masking, test-enable and 3-bit individual threshold adjust. After adjustment the threshold spread is reduced to 80 e- rms. Absolute calibration of the electrically measured equivalent charge can be done once the readout chip is bump-bonded to a detector.

  3. Integration of Single-Photon Sources and Detectors on GaAs

    Directory of Open Access Journals (Sweden)

    Giulia Enrica Digeronimo

    2016-10-01

    Full Text Available Quantum photonic integrated circuits (QPICs on a GaAs platform allow the generation, manipulation, routing, and detection of non-classical states of light, which could pave the way for quantum information processing based on photons. In this article, the prototype of a multi-functional QPIC is presented together with our recent achievements in terms of nanofabrication and integration of each component of the circuit. Photons are generated by excited InAs quantum dots (QDs and routed through ridge waveguides towards photonic crystal cavities acting as filters. The filters with a transmission of 20% and free spectral range ≥66 nm are able to select a single excitonic line out of the complex emission spectra of the QDs. The QD luminescence can be measured by on-chip superconducting single photon detectors made of niobium nitride (NbN nanowires patterned on top of a suspended nanobeam, reaching a device quantum efficiency up to 28%. Moreover, two electrically independent detectors are integrated on top of the same nanobeam, resulting in a very compact autocorrelator for on-chip g(2(τ measurements.

  4. Quantum interference of electrically generated single photons from a quantum dot

    International Nuclear Information System (INIS)

    Patel, Raj B; Bennett, Anthony J; Shields, Andrew J; Cooper, Ken; Atkinson, Paola; Nicoll, Christine A; Ritchie, David A

    2010-01-01

    Quantum interference lies at the foundation of many protocols for scalable quantum computing and communication with linear optics. To observe these effects the light source must emit photons that are indistinguishable. From a technological standpoint, it would be beneficial to have electrical control over the emission. Here we report of an electrically driven single-photon source emitting indistinguishable photons. The device consists of a layer of InAs quantum dots embedded in the intrinsic region of a p-i-n diode. Indistinguishability of consecutive photons is tested in a two-photon interference experiment under two modes of operation, continuous and pulsed current injection. We also present a complete theory based on the interference of photons with a Lorentzian spectrum which we compare to both our continuous wave and pulsed experiments. In the former case, a visibility was measured limited only by the timing resolution of our detection system. In the case of pulsed injection, we employ a two-pulse voltage sequence which suppresses multi-photon emission and allows us to carry out temporal filtering of photons which have undergone dephasing. The characteristic Hong-Ou-Mandel 'dip' is measured, resulting in a visibility of 64 ± 4%.

  5. Quantitation of postexercise lung thallium-201 uptake during single photon emission computed tomography

    International Nuclear Information System (INIS)

    Kahn, J.K.; Carry, M.M.; McGhie, I.; Pippin, J.J.; Akers, M.S.; Corbett, J.R.

    1989-01-01

    To test the hypothesis that analysis of lung thallium uptake measured during single photon emission computed tomography (SPECT) yields supplementary clinical information as reported for planar imaging, quantitative analysis of lung thallium uptake following maximal exercise was performed in 40 clinically normal subjects (Group 1) and 15 angiographically normal subjects (Group 2). Lung thallium uptake was measured from anterior projection images using a ratio of heart-to-lung activities. Seventy subjects with coronary artery disease (CAD) (Group 3) determined by angiography (greater than or equal to 70% luminal stenosis) underwent thallium perfusion SPECT. Thirty-nine percent of these subjects had multivessel and 61% had single vessel CAD. Lung thallium uptake was elevated in 47 of 70 (67%) Group 3 subjects. Group 3 subjects with elevated lung thallium uptake did not differ from Group 3 subjects with normal lung thallium uptake with respect to extent or distribution of coronary artery disease, left ventricular function, or severity of myocardial ischemia as determined by exercise and redistribution thallium SPECT. Thus, the measurement of thallium lung uptake from anterior projection images obtained during SPECT frequently identifies patients with CAD, but it may not provide supplementary information regarding the extent of myocardial ischemia or ventricular dysfunction

  6. Time sequential single photon emission computed tomography studies in brain tumour using thallium-201

    International Nuclear Information System (INIS)

    Ueda, Takashi; Kaji, Yasuhiro; Wakisaka, Shinichiro; Watanabe, Katsushi; Hoshi, Hiroaki; Jinnouchi, Seishi; Futami, Shigemi

    1993-01-01

    Time sequential single photon emission computed tomography (SPECT) studies using thallium-201 were performed in 25 patients with brain tumours to evaluate the kinetics of thallium in the tumour and the biological malignancy grade preoperatively. After acquisition and reconstruction of SPECT data from 1 min post injection to 48 h (1, 2, 3, 4, 5, 6, 7, 8, 9, 10 and 15-20 min, followed by 4-6, 24 and 48 h), the thallium uptake ratio in the tumour versus the homologous contralateral area of the brain was calculated and compared with findings of X-ray CT, magnetic resonance imaging, cerebral angiography and histological investigations. Early uptake of thallium in tumours was related to tumour vascularity and the disruption of the blood-brain barrier. High and rapid uptake and slow reduction of thallium indicated a hypervascular malignant tumour; however, high and rapid uptake but rapid reduction of thallium indicated a hypervascular benign tumour, such as meningioma. Hypovascular and benign tumours tended to show low uptake and slow reduction of thallium. Long-lasting retention or uptake of thallium indicates tumour malignancy. (orig.)

  7. A bright single-photon source based on a photonic trumpet

    DEFF Research Database (Denmark)

    Munsch, Mathieu; Malik, Nitin S.; Bleuse, Joël

    Fiber-like photonic nanowires, which are optical waveguides made of a high refractive index material n, have recently emerged as non-resonant systems providing an efficient spontaneous emission (SE) control. When they embed a quantum emitter like a quantum dot (QD), they find application to the r......Fiber-like photonic nanowires, which are optical waveguides made of a high refractive index material n, have recently emerged as non-resonant systems providing an efficient spontaneous emission (SE) control. When they embed a quantum emitter like a quantum dot (QD), they find application...... to the realization of bright sources of quantum light and, reversibly, provide an efficient interface between propagating photons and the QD. For a wire diameter ∼ λ/n (λ is the operation wavelength), the fraction of QD SE coupled to the fundamental guided mode exceeds 90%. The collection of the photons can...... be brought close to unity with a proper engineering of the wire ends. In particular, a tapering of the top wire end is necessary to achieve a directive far-field emission pattern [1]. Recently, we have realized a single-photon source featuring a needle-like taper. The source efficiency, though record...

  8. Critical examination of the uniformity requirements for single-photon emission computed tomography.

    Science.gov (United States)

    O'Connor, M K; Vermeersch, C

    1991-01-01

    It is generally recognized that single-photon emission computed tomography (SPECT) imposes very stringent requirements on gamma camera uniformity to prevent the occurrence of ring artifacts. The purpose of this study was to examine the relationship between nonuniformities in the planar data and the magnitude of the consequential ring artifacts in the transaxial data, and how the perception of these artifacts is influenced by factors such as reconstruction matrix size, reconstruction filter, and image noise. The study indicates that the relationship between ring artifact magnitude and image noise is essentially independent of the acquisition or reconstruction matrix sizes, but is strongly dependent upon the type of smoothing filter applied during the reconstruction process. Furthermore, the degree to which a ring artifact can be perceived above image noise is dependent on the size and location of the nonuniformity in the planar data, with small nonuniformities (1-2 pixels wide) close to the center of rotation being less perceptible than those further out (8-20 pixels). Small defects or nonuniformities close to the center of rotation are thought to cause the greatest potential corruption to tomographic data. The study indicates that such may not be the case. Hence the uniformity requirements for SPECT may be less demanding than was previously thought.

  9. Fully differential single-photon double ionization of neon and argon

    Science.gov (United States)

    Yip, Frank; Martin, Fernando; Rescigno, Thomas; McCurdy, C.

    2013-05-01

    Double photoionization of neon and argon differ significantly from helium in that three different final state couplings of the residual double ion (1 S , 1 D , and 3 P) are possible and greatly impact the observed angular distributions, but the multi-electron nature of such targets makes ab initio theoretical treatments of this correlated process a challenge. Triply differential cross sections (TDCS) have been calculated for single photon double ionization of these heavier rare gases at various photon energies by utilizing an expanded frozen-core treatment to represent the remaining N - 2 target electrons of the residual ion. The resulting angular distributions are compared with and show significant agreement with existing experimental data. Work supported by U. S. Dept. of Energy, Office of Basic Energy Sciences, Division of Chemical Sciences Contract DE-AC02-05CH11231, by the MICINN Projects No. FIS2010-15127, No. ACI2008-0777,No. CSD 2007-00010, and ERC Advanced Grant 290853.

  10. Single-Photon Avalanche Diode with Enhanced NIR-Sensitivity for Automotive LIDAR Systems.

    Science.gov (United States)

    Takai, Isamu; Matsubara, Hiroyuki; Soga, Mineki; Ohta, Mitsuhiko; Ogawa, Masaru; Yamashita, Tatsuya

    2016-03-30

    A single-photon avalanche diode (SPAD) with enhanced near-infrared (NIR) sensitivity has been developed, based on 0.18 μm CMOS technology, for use in future automotive light detection and ranging (LIDAR) systems. The newly proposed SPAD operating in Geiger mode achieves a high NIR photon detection efficiency (PDE) without compromising the fill factor (FF) and a low breakdown voltage of approximately 20.5 V. These properties are obtained by employing two custom layers that are designed to provide a full-depletion layer with a high electric field profile. Experimental evaluation of the proposed SPAD reveals an FF of 33.1% and a PDE of 19.4% at 870 nm, which is the laser wavelength of our LIDAR system. The dark count rate (DCR) measurements shows that DCR levels of the proposed SPAD have a small effect on the ranging performance, even if the worst DCR (12.7 kcps) SPAD among the test samples is used. Furthermore, with an eye toward vehicle installations, the DCR is measured over a wide temperature range of 25-132 °C. The ranging experiment demonstrates that target distances are successfully measured in the distance range of 50-180 cm.

  11. Single-Photon Avalanche Diode with Enhanced NIR-Sensitivity for Automotive LIDAR Systems

    Directory of Open Access Journals (Sweden)

    Isamu Takai

    2016-03-01

    Full Text Available A single-photon avalanche diode (SPAD with enhanced near-infrared (NIR sensitivity has been developed, based on 0.18 μm CMOS technology, for use in future automotive light detection and ranging (LIDAR systems. The newly proposed SPAD operating in Geiger mode achieves a high NIR photon detection efficiency (PDE without compromising the fill factor (FF and a low breakdown voltage of approximately 20.5 V. These properties are obtained by employing two custom layers that are designed to provide a full-depletion layer with a high electric field profile. Experimental evaluation of the proposed SPAD reveals an FF of 33.1% and a PDE of 19.4% at 870 nm, which is the laser wavelength of our LIDAR system. The dark count rate (DCR measurements shows that DCR levels of the proposed SPAD have a small effect on the ranging performance, even if the worst DCR (12.7 kcps SPAD among the test samples is used. Furthermore, with an eye toward vehicle installations, the DCR is measured over a wide temperature range of 25–132 °C. The ranging experiment demonstrates that target distances are successfully measured in the distance range of 50–180 cm.

  12. Single photon emission computed tomography and albumin colloid imaging of the liver

    International Nuclear Information System (INIS)

    Croft, B.Y.; Teates, C.D.; Honeyman, J.C.

    1984-01-01

    A single photon emission computed tomography (ECT) system using the GE 400T Anger camera with 37 PM tubes and the SPETS software has been installed in our clinical laboratory. It has been used in the study of liver imaging with Tc-99m albumin colloid and other agents. The object of the study is to define what improvement in liver diagnosis might be made using ECT. Patients were injected with 3-4 mCi (ca 120 MBq) of colloid; five standard liver-spleen views and a 64-image ECT study were acquired. The ECT images were acquired either in a circle of the radius of the longer transverse axis of the patient or in an ellipse to match the patient contour. Studies were corrected for the attenuation of the Tc-99m gamma rays by tissue. A series of normal and abnormal patients have been studied and the data analyzed. The significant change in the technique of ECT imaging is the elliptical motion of the camera head which allows a better approximation of the patient contour and improves the spatial resolution of the images. (orig.)

  13. Single-photon tomographic determination of regional cerebral blood flow in psychiatric disorders

    International Nuclear Information System (INIS)

    Devous, M.D. Sr.; Rush, A.J.; Schlesser, M.A.; Debus, J.; Raese, J.D.; Chehabi, H.H.; Bonte, F.J.

    1984-01-01

    Regional cerebral blood flow (rCBF) was measured by single-photon emission computed tomography (SPECT) of 133-Xe washout in 29 normal volunteers, 22 unipolar endogenous depressives (UPE), 9 unipolar nonendogenous depressives (UPNE), 13 bipolar depressed patients (BPD), and 14 schizophrenic patients (SCHZ). RCBF was measured 2 and 6 cm above and parallel to the cantho-meatal line and quantitated in 14 gray matter regions. Most subjects were drug-free for 4-14 days. Diagnoses were made by experienced clinicians employing the Research Diagnostic Criteria, the Hamilton Rating Scale, and the dexamethasone suppression test. SCHZ were rated with the Brief Psychiatric Rating Scale. UPE had reduced flow compared to normals in the right parietal and temporal lobes and a nonsignificant trend toward left temporal flow reductions. UPNE were not different from normal or other patient groups. BPD had significant flow elevations in the left hemisphere relative to normal, and in both hemispheres relative to UPE. SCHZ were not significantly different from normal or other patient groups. Anterior-posterior flow shifts were evaluated by subtracting parietal or temporal flows from frontal flows. SCHZ demonstrated a greater posterior shift (lower relative frontal lobe flow) in comparison to both UPE and UPNE. The most significant regional flow abnormalities were observed as frontal flow reductions in individual SCHZ, although these were not significant in the whole group in comparison to normal

  14. Bone single photon emission computed tomography (SPECT in a patient with Pancoast tumor: a case report

    Directory of Open Access Journals (Sweden)

    Hamid Javadi

    Full Text Available CONTEXT: Non-small cell lung carcinomas (NSCLCs of the superior sulcus are considered to be the most challenging type of malignant thoracic disease. In this disease, neoplasms originating mostly from the extreme apex of the lung expand to the chest wall and thoracic inlet structures. Multiple imaging procedures have been applied to identify tumors and to stage and predict tumor resectability in surgical operations. Clinical examinations to localize pain complaints in shoulders and down the arms, and to screen for Horner's syndrome and abnormalities seen in paraclinical assessments, have been applied extensively for differential diagnosis of superior sulcus tumors. Although several types of imaging have been utilized for diagnosing and staging Pancoast tumors, there have been almost no reports on the efficiency of whole-body bone scans (WBBS for detecting the level of abnormality in cases of superior sulcus tumors. CASE REPORT: We describe a case of Pancoast tumor in which technetium-99m methylene diphosphonate (Tc-99m MDP bone single-photon emission-computed tomography (SPECT was able to accurately detect multiple areas of abnormality in the vertebrae and ribs. In describing this case, we stress the clinical and diagnostic points, in the hope of stimulating a higher degree of suspicion and thereby facilitating appropriate diagnosis and treatment. From the results of this study, further clinical trials to evaluate the potential of SPECT as an efficient imaging tool for the work-up on cases of Pancoast tumor are recommended.

  15. Statistical evaluation of single-photon emission computed tomography image using smoothed bootstrap method

    International Nuclear Information System (INIS)

    Tsukamoto, Megumi; Hatabu, Asuka; Takahashi, Yoshitake; Matsuda, Hiroshi; Okamoto, Kousuke; Yamashita, Noriyuki; Takagi, Tatsuya

    2013-01-01

    Many of the neurodegenerative diseases associated with a decrease in regional cerebral blood flow (rCBF) are untreatable, and the appropriate therapeutic strategy is to slow the progression of the disease. Therefore, it is important that a definitive diagnosis is made as soon as possible when such diseases are suspected. Diagnostic imaging methods, such as positron emission tomography (PET) and single-photon emission computed tomography (SPECT), play an important role in such a definitive diagnosis. Since several problems arise when evaluating these images visually, a procedure to evaluate them objectively is necessary, and studies of image analyses using statistical evaluations have been suggested. However, the assumed data distribution in a statistical procedure may occasionally be inappropriate. Therefore, to evaluate the decrease of rCBF, it is important to use a statistical procedure without assumptions about the data distribution. In this study, we propose a new procedure that uses nonparametric or smoothed bootstrap methods to calculate a standardized distribution of the Z-score without assumptions about the data distribution. To test whether the judgment of the proposed procedure is equivalent to that of an evaluation based on the Z-score with a fixed threshold, the procedure was applied to a sample data set whose size was large enough to be appropriate for the assumption of the Z-score. As a result, the evaluations of the proposed procedure were equivalent to that of an evaluation based on the Z-score. (author)

  16. Diagnostic accuracy of single photon emission CT in Alzheimer-type dementia

    International Nuclear Information System (INIS)

    Hanyu, Haruki; Abe, Shinei; Arai, Hisayuki; Asano, Tetsuichi; Iwamoto, Toshihiko; Takasaki, Masaru; Suzuki, Takanari

    1992-01-01

    To determine the diagnostic accuracy of single photon emission computed tomography (SPECT) with 123 I-IMP in Alzheimer-type dementia (ATD), we studied 46 ATD patients and 23 healthy controls. The patients fulfilled the NINCDS-ADRDA criteria for probable or definite ATD and were classified as having mild, moderate, and severe ATD by neuropsychological examinations. To assess regional cerebral blood flow, we performed qualitative SPECT image analysis without any knowledge of the subject's clinical classification. The image was regarded as abnormal if cerebral blood flow was reduced in the unlilateral or bilateral temporoparietal association areas, with or without any reduction of flow in other brain regions. The diagnostic sensitivity (abnormal image/ patient) of 123 I-IMP SPECT in mild, moderate and severe ATD was 67%, 86% and 92%, because an abnormal image was found in only 2/23 healthy controls. Eight ATD patients without reduced temporoparietal perfusion showed normal perfusion or frontal hypoperfusion. These results suggest that 123 I-IMP SPECT may provide an accurate and sensitive diagnostic marker for ATD. The detection of these characteristic abnormalities of cerebral perfusion could well be applied to the clinical diagnosis of ATD. (author)

  17. [Restoration filtering based on projection power spectrum for single-photon emission computed tomography].

    Science.gov (United States)

    Kubo, N

    1995-04-01

    To improve the quality of single-photon emission computed tomographic (SPECT) images, a restoration filter has been developed. This filter was designed according to practical "least squares filter" theory. It is necessary to know the object power spectrum and the noise power spectrum. The power spectrum is estimated from the power spectrum of a projection, when the high-frequency power spectrum of a projection is adequately approximated as a polynomial exponential expression. A study of the restoration with the filter based on a projection power spectrum was conducted, and compared with that of the "Butterworth" filtering method (cut-off frequency of 0.15 cycles/pixel), and "Wiener" filtering (signal-to-noise power spectrum ratio was a constant). Normalized mean-squared errors (NMSE) of the phantom, two line sources located in a 99mTc filled cylinder, were used. NMSE of the "Butterworth" filter, "Wiener" filter, and filtering based on a power spectrum were 0.77, 0.83, and 0.76 respectively. Clinically, brain SPECT images utilizing this new restoration filter improved the contrast. Thus, this filter may be useful in diagnosis of SPECT images.

  18. Intelligence quotient-adjusted memory impairment is associated with abnormal single photon emission computed tomography perfusion.

    Science.gov (United States)

    Rentz, Dorene M; Huh, Terri J; Sardinha, Lisa M; Moran, Erin K; Becker, John A; Daffner, Kirk R; Sperling, Reisa A; Johnson, Keith A

    2007-09-01

    Cognitive reserve among highly intelligent older individuals makes detection of early Alzheimer's disease (AD) difficult. We tested the hypothesis that mild memory impairment determined by IQ-adjusted norms is associated with single photon emission computed tomography (SPECT) perfusion abnormality at baseline and predictive of future decline. Twenty-three subjects with a Clinical Dementia Rating (CDR) score of 0, were reclassified after scores were adjusted for IQ into two groups, 10 as having mild memory impairments for ability (IQ-MI) and 13 as memory-normal (IQ-MN). Subjects underwent cognitive and functional assessments at baseline and annual follow-up for 3 years. Perfusion SPECT was acquired at baseline. At follow-up, the IQ-MI subjects demonstrated decline in memory, visuospatial processing, and phonemic fluency, and 6 of 10 had progressed to a CDR of 0.5, while the IQ-MN subjects did not show decline. The IQ-MI group had significantly lower perfusion than the IQ-MN group in parietal/precuneus, temporal, and opercular frontal regions. In contrast, higher perfusion was observed in IQ-MI compared with IQ-MN in the left medial frontal and rostral anterior cingulate regions. IQ-adjusted memory impairment in individuals with high cognitive reserve is associated with baseline SPECT abnormality in a pattern consistent with prodromal AD and predicts subsequent cognitive and functional decline.

  19. Single-photon test of hyper-complex quantum theories using a metamaterial.

    Science.gov (United States)

    Procopio, Lorenzo M; Rozema, Lee A; Wong, Zi Jing; Hamel, Deny R; O'Brien, Kevin; Zhang, Xiang; Dakić, Borivoje; Walther, Philip

    2017-04-21

    In standard quantum mechanics, complex numbers are used to describe the wavefunction. Although this has so far proven sufficient to predict experimental results, there is no theoretical reason to choose them over real numbers or generalizations of complex numbers, that is, hyper-complex numbers. Experiments performed to date have proven that real numbers are insufficient, but the need for hyper-complex numbers remains an open question. Here we experimentally probe hyper-complex quantum theories, studying one of their deviations from complex quantum theory: the non-commutativity of phases. We do so by passing single photons through a Sagnac interferometer containing both a metamaterial with a negative refractive index, and a positive phase shifter. To accomplish this we engineered a fishnet metamaterial to have a negative refractive index at 780 nm. We show that the metamaterial phase commutes with other phases with high precision, allowing us to place limits on a particular prediction of hyper-complex quantum theories.

  20. Aphasia following left thalamic hemorrhage. A study by Western Aphasia Battery and single photon emission CT

    Energy Technology Data Exchange (ETDEWEB)

    Makishita, Hideo; Miyasaka, Motomaro; Tanizaki, Yoshio; Yanagisawa, Nobuo; Sugishita, Morihiro

    1984-07-01

    A report is given of 7 patients with left thalamic hemorrhage in the chronic stage (from 1.5 months to 4.5 months) in which language disorders were examined by Western Aphasia Battery (WAB) and cerebral blood flow was measured by single photon emission CT. Examination of language by WAB revealed 4 aphasics out of 7 cases, and 3 patients had no language deficit. The patient with Wernicke's aphasia showed low density area only in the left posterior thalamus in X-ray CT, and revealed severe low blood flow area extending to left temporal lobe in emission CT. In the case with transcortical sensory aphasia, although X-ray CT showed no obvious low density area, emission CT revealed moderate low flow area in the left temporooccipital region and low blood flow at the left thalamus. In one of the two patients classified as anomic aphasia, emission CT showed slight low flow area at the temporo-occipital region similar to the case with transcortical sensory aphasia. In another case with anomic aphasia there was a wide low density area all over the left thalamus and midline shift to the right in X-ray CT, and emission CT showed severe low blood flow in the same region spreading widely toward the cerebral surface. In all of the 3 patients without aphasia, emission CT showed low flow region restricted to the left thalamus.

  1. Bone mineral content measurement in small infants by single-photon absorptiometry: current methodologic issues

    International Nuclear Information System (INIS)

    Steichen, J.J.; Asch, P.A.; Tsang, R.C.

    1988-01-01

    Single-photon absorptiometry (SPA), developed in 1963 and adapted for infants by Steichen et al. in 1976, is an important tool to quantitate bone mineralization in infants. Studies of infants in which SPA was used include studies of fetal bone mineralization and postnatal bone mineralization in very low birth weight infants. The SPA technique has also been used as a research tool to investigate longitudinal bone mineralization and to study the effect of nutrition and disease processes such as rickets or osteopenia of prematurity. At present, it has little direct clinical application for diagnosing bone disease in single patients. The bones most often used to measure bone mineral content (BMC) are the radius, the ulna, and, less often, the humerus. The radius appears to be preferred as a suitable bone to measure BMC in infants. It is easily accessible; anatomic reference points are easily palpated and have a constant relationship to the radial mid-shaft site; soft tissue does not affect either palpation of anatomic reference points or BMC quantitation in vivo. The peripheral location of the radius minimizes body radiation exposure. Trabecular and cortical bone can be measured separately. Extensive background studies exist on radial BMC in small infants. Most important, the radius has a relatively long zone of constant BMC. Finally, SPA for BMC in the radius has a high degree of precision and accuracy. 61 references

  2. Performance trade-offs in single-photon avalanche diode miniaturization

    Science.gov (United States)

    Finkelstein, Hod; Hsu, Mark J.; Zlatanovic, Sanja; Esener, Sadik

    2007-10-01

    Single-photon avalanche diodes (SPADs) provide photons' time of arrival for various applications. In recent years, attempts have been made to miniaturize SPADs in order to facilitate large-array integration and in order to reduce the dead time of the device. We investigate the benefits and drawbacks of device miniaturization by characterizing a new fast SPAD in a commercial 0.18μm complementary metal oxide semiconductor technology. The device employs a novel and efficient guard ring, resulting in a high fill factor. Thanks to its small size, the dead time is only 5ns, resulting in the fastest reported SPAD to date. However, the short dead time is accompanied by a high after-pulsing rate, which we show to be a limiting parameter for SPAD miniaturization. We describe a new and compact active-recharge scheme which improves signal-to-noise tenfold compared with the passive configuration, using a fraction of the area of state-of-the-art active-recharge circuits, and without increasing the dead time. The performance of compact SPADs stands to benefit such applications as high-resolution fluorescence-lifetime imaging, active-illumination three-dimensional imagers, and quantum key distribution systems.

  3. Development of a Portable Single Photon Ionization-Photoelectron Ionization Time-of-Flight Mass Spectrometer

    Directory of Open Access Journals (Sweden)

    Yunguang Huang

    2015-01-01

    Full Text Available A vacuum ultraviolet lamp based single photon ionization- (SPI- photoelectron ionization (PEI portable reflecting time-of-flight mass spectrometer (TOFMS was designed for online monitoring gas samples. It has a dual mode ionization source: SPI for analyte with ionization energy (IE below 10.6 eV and PEI for IE higher than 10.6 eV. Two kinds of sampling inlets, a capillary inlet and a membrane inlet, are utilized for high concentration and trace volatile organic compounds, respectively. A mass resolution of 1100 at m/z 64 has been obtained with a total size of 40 × 31 × 29 cm, the weight is 27 kg, and the power consumption is only 70 W. A mixture of benzene, toluene, and xylene (BTX, SO2, and discharging products of SF6 were used to test its performance, and the result showed that the limit of quantitation for BTX is as low as 5 ppbv (S/N = 10 : 1 with linear dynamic ranges greater than four orders of magnitude. The portable TOFMS was also evaluated by analyzing volatile organic compounds from wine and decomposition products of SF6 inside of a gas-insulated switchgear.

  4. CLARO: an ASIC for high rate single photon counting with multi-anode photomultipliers

    Science.gov (United States)

    Baszczyk, M.; Carniti, P.; Cassina, L.; Cotta Ramusino, A.; Dorosz, P.; Fiorini, M.; Gotti, C.; Kucewicz, W.; Malaguti, R.; Pessina, G.

    2017-08-01

    The CLARO is a radiation-hard 8-channel ASIC designed for single photon counting with multi-anode photomultiplier tubes. Each channel outputs a digital pulse when the input signal from the photomultiplier crosses a configurable threshold. The fast return to baseline, typically within 25 ns, and below 50 ns in all conditions, allows to count up to 107 hits/s on each channel, with a power consumption of about 1 mW per channel. The ASIC presented here is a much improved version of the first 4-channel prototype. The threshold can be precisely set in a wide range, between 30 ke- (5 fC) and 16 Me- (2.6 pC). The noise of the amplifier with a 10 pF input capacitance is 3.5 ke- (0.6 fC) RMS. All settings are stored in a 128-bit configuration and status register, protected against soft errors with triple modular redundancy. The paper describes the design of the ASIC at transistor-level, and demonstrates its performance on the test bench.

  5. Single-photon blockade in a hybrid cavity-optomechanical system via third-order nonlinearity

    Science.gov (United States)

    Sarma, Bijita; Sarma, Amarendra K.

    2018-04-01

    Photon statistics in a weakly driven optomechanical cavity, with Kerr-type nonlinearity, are analyzed both analytically and numerically. The single-photon blockade effect is demonstrated via calculations of the zero-time-delay second-order correlation function g (2)(0). The analytical results obtained by solving the Schrödinger equation are in complete conformity with the results obtained through numerical solution of the quantum master equation. A systematic study on the parameter regime for observing photon blockade in the weak coupling regime is reported. The parameter regime where the photon blockade is not realizable due to the combined effect of nonlinearities owing to the optomechanical coupling and the Kerr-effect is demonstrated. The experimental feasibility with state-of-the-art device parameters is discussed and it is observed that photon blockade could be generated at the telecommunication wavelength. An elaborate analysis of the thermal effects on photon antibunching is presented. The system is found to be robust against pure dephasing-induced decoherences and thermal phonon number fluctuations.

  6. An accurate behavioral model for single-photon avalanche diode statistical performance simulation

    Science.gov (United States)

    Xu, Yue; Zhao, Tingchen; Li, Ding

    2018-01-01

    An accurate behavioral model is presented to simulate important statistical performance of single-photon avalanche diodes (SPADs), such as dark count and after-pulsing noise. The derived simulation model takes into account all important generation mechanisms of the two kinds of noise. For the first time, thermal agitation, trap-assisted tunneling and band-to-band tunneling mechanisms are simultaneously incorporated in the simulation model to evaluate dark count behavior of SPADs fabricated in deep sub-micron CMOS technology. Meanwhile, a complete carrier trapping and de-trapping process is considered in afterpulsing model and a simple analytical expression is derived to estimate after-pulsing probability. In particular, the key model parameters of avalanche triggering probability and electric field dependence of excess bias voltage are extracted from Geiger-mode TCAD simulation and this behavioral simulation model doesn't include any empirical parameters. The developed SPAD model is implemented in Verilog-A behavioral hardware description language and successfully operated on commercial Cadence Spectre simulator, showing good universality and compatibility. The model simulation results are in a good accordance with the test data, validating high simulation accuracy.

  7. Frequency and bandwidth conversion of single photons in a room-temperature diamond quantum memory.

    Science.gov (United States)

    Fisher, Kent A G; England, Duncan G; MacLean, Jean-Philippe W; Bustard, Philip J; Resch, Kevin J; Sussman, Benjamin J

    2016-04-05

    The spectral manipulation of photons is essential for linking components in a quantum network. Large frequency shifts are needed for conversion between optical and telecommunication frequencies, while smaller shifts are useful for frequency-multiplexing quantum systems, in the same way that wavelength division multiplexing is used in classical communications. Here we demonstrate frequency and bandwidth conversion of single photons in a room-temperature diamond quantum memory. Heralded 723.5 nm photons, with 4.1 nm bandwidth, are stored as optical phonons in the diamond via a Raman transition. Upon retrieval from the diamond memory, the spectral shape of the photons is determined by a tunable read pulse through the reverse Raman transition. We report central frequency tunability over 4.2 times the input bandwidth, and bandwidth modulation between 0.5 and 1.9 times the input bandwidth. Our results demonstrate the potential for diamond, and Raman memories in general, as an integrated platform for photon storage and spectral conversion.

  8. High-Dimensional Single-Photon Quantum Gates: Concepts and Experiments.

    Science.gov (United States)

    Babazadeh, Amin; Erhard, Manuel; Wang, Feiran; Malik, Mehul; Nouroozi, Rahman; Krenn, Mario; Zeilinger, Anton

    2017-11-03

    Transformations on quantum states form a basic building block of every quantum information system. From photonic polarization to two-level atoms, complete sets of quantum gates for a variety of qubit systems are well known. For multilevel quantum systems beyond qubits, the situation is more challenging. The orbital angular momentum modes of photons comprise one such high-dimensional system for which generation and measurement techniques are well studied. However, arbitrary transformations for such quantum states are not known. Here we experimentally demonstrate a four-dimensional generalization of the Pauli X gate and all of its integer powers on single photons carrying orbital angular momentum. Together with the well-known Z gate, this forms the first complete set of high-dimensional quantum gates implemented experimentally. The concept of the X gate is based on independent access to quantum states with different parities and can thus be generalized to other photonic degrees of freedom and potentially also to other quantum systems.

  9. Control of single photon emitters in semiconductor nanowires by surface acoustic waves

    Science.gov (United States)

    Lazić, S.; Hernández-Mínguez, A.; Santos, P. V.

    2017-08-01

    We report on an experimental study into the effects of surface acoustic waves on the optical emission of dot-in-a-nanowire heterostructures in III-V material systems. Under direct optical excitation, the excitonic energy levels in III-nitride dot-in-a-nanowire heterostructures oscillate at the acoustic frequency, producing a characteristic splitting of the emission lines in the time-integrated photoluminescence spectra. This acoustically induced periodic tuning of the excitonic transition energies is combined with spectral detection filtering and employed as a tool to regulate the temporal output of anti-bunched photons emitted from these nanowire quantum dots. In addition, the acoustic transport of electrons and holes along a III-arsenide nanowire injects the electric charges into an ensemble of quantum dot-like recombination centers that are spatially separated from the optical excitation area. The acoustic population and depopulation mechanism determines the number of carrier recombination events taking place simultaneously in the ensemble, thus allowing control of the anti-bunching degree of the emitted photons. The results presented are relevant for the dynamic control of single photon emission in III-V semiconductor heterostructures.

  10. Development of a Portable Single Photon Ionization-Photoelectron Ionization Time-of-Flight Mass Spectrometer

    Science.gov (United States)

    Huang, Yunguang; Li, Jinxu; Tang, Bin; Zhu, Liping; Hou, Keyong; Li, Haiyang

    2015-01-01

    A vacuum ultraviolet lamp based single photon ionization- (SPI-) photoelectron ionization (PEI) portable reflecting time-of-flight mass spectrometer (TOFMS) was designed for online monitoring gas samples. It has a dual mode ionization source: SPI for analyte with ionization energy (IE) below 10.6 eV and PEI for IE higher than 10.6 eV. Two kinds of sampling inlets, a capillary inlet and a membrane inlet, are utilized for high concentration and trace volatile organic compounds, respectively. A mass resolution of 1100 at m/z 64 has been obtained with a total size of 40 × 31 × 29 cm, the weight is 27 kg, and the power consumption is only 70 W. A mixture of benzene, toluene, and xylene (BTX), SO2, and discharging products of SF6 were used to test its performance, and the result showed that the limit of quantitation for BTX is as low as 5 ppbv (S/N = 10 : 1) with linear dynamic ranges greater than four orders of magnitude. The portable TOFMS was also evaluated by analyzing volatile organic compounds from wine and decomposition products of SF6 inside of a gas-insulated switchgear. PMID:26587023

  11. Wireless fluorescence capsule for endoscopy using single photon-based detection

    Science.gov (United States)

    Al-Rawhani, Mohammed A.; Beeley, James; Cumming, David R. S.

    2015-12-01

    Fluorescence Imaging (FI) is a powerful technique in biological science and clinical medicine. Current FI devices that are used either for in-vivo or in-vitro studies are expensive, bulky and consume substantial power, confining the technique to laboratories and hospital examination rooms. Here we present a miniaturised wireless fluorescence endoscope capsule with low power consumption that will pave the way for future FI systems and applications. With enhanced sensitivity compared to existing technology we have demonstrated that the capsule can be successfully used to image tissue autofluorescence and targeted fluorescence via fluorophore labelling of tissues. The capsule incorporates a state-of-the-art complementary metal oxide semiconductor single photon avalanche detector imaging array, miniaturised optical isolation, wireless technology and low power design. When in use the capsule consumes only 30.9 mW, and deploys very low-level 468 nm illumination. The device has the potential to replace highly power-hungry intrusive optical fibre based endoscopes and to extend the range of clinical examination below the duodenum. To demonstrate the performance of our capsule, we imaged fluorescence phantoms incorporating principal tissue fluorophores (flavins) and absorbers (haemoglobin). We also demonstrated the utility of marker identification by imaging a 20 μM fluorescein isothiocyanate (FITC) labelling solution on mammalian tissue.

  12. Development of a high-performance multichannel system for time-correlated single photon counting

    Science.gov (United States)

    Peronio, P.; Cominelli, A.; Acconcia, G.; Rech, I.; Ghioni, M.

    2017-05-01

    Time-Correlated Single Photon Counting (TCSPC) is one of the most effective techniques for measuring weak and fast optical signals. It outperforms traditional "analog" techniques due to its high sensitivity along with high temporal resolution. Despite those significant advantages, a main drawback still exists, which is related to the long acquisition time needed to perform a measurement. In past years many TCSPC systems have been developed with higher and higher number of channels, aimed to dealing with that limitation. Nevertheless, modern systems suffer from a strong trade-off between parallelism level and performance: the higher the number of channels the poorer the performance. In this work we present the design of a 32x32 TCSPC system meant for overtaking the existing trade-off. To this aim different technologies has been employed, to get the best performance both from detectors and sensing circuits. The exploitation of different technologies will be enabled by Through Silicon Vias (TSVs) which will be investigated as a possible solution for connecting the detectors to the sensing circuits. When dealing with a high number of channels, the count rate is inevitably set by the affordable throughput to the external PC. We targeted a throughput of 10Gb/s, which is beyond the state of the art, and designed the number of TCSPC channels accordingly. A dynamic-routing logic will connect the detectors to the lower number of acquisition chains.

  13. Design and analysis of CMOS single photon counting avalanche photodiodes integrated with active quenching circuits

    International Nuclear Information System (INIS)

    Kim, Kwang Hyun; Kim, Young Soo

    2008-01-01

    The CMOS SPADs (Single Photon Avalanche Diodes) integrated with active quenching circuits were fabricated on same chip using AMIS 0.7 μm high voltage CMOS process without any process modifications. The SPADs have N+/P-substrate structure and their diameter of photo sensing area are 25 μm, 50 μm, 100 μm, 400 μm, and 800 μm. The avalanche multiplication is occurred at 10.7 V, and the photocurrent gain at 11 V reverse bias voltage is about 1000. In zero bias condition, the maximum quantum efficiency appears at 650 nm wavelength, and it corresponds to around 30%. The active quenching circuit is composed to a comparator, three monostable, and two MOS switch. As a circuit simulation results, the comparator and the monostable generate ∼22 nsec and ∼1 nsec delayed output pulse, respectively. The dead time of the active quenching circuits integrated with SPADs is about 100 nsec as a measured result. (author)

  14. Regional cerebral blood flow analysis of vascular dementia by the single photon emission computed tomography

    International Nuclear Information System (INIS)

    Miyakawa, Kouichi; Watanabe, Sho; Suzuki, Michiyo; Kamijima, Gonbei

    1989-01-01

    In order to evaluate the relationship between the regional cerebral blood flow (CBF) and cerebrovascular dementia, eleven patients with vascular dementia and eight patients with non-demented infarction were studied and regional CBF were measured quantitatively with single photon emission computed tomography (SPECT) by using N-isopropyl-p-(I-123) iodoamphetamine. All cases were basal infarction and vascular dementia were diagnosed by less than 21.5 of the Hasegawa's dementia score and more than 7 of Hachinsk's ischemic score. The results of the present study were as follows: (1) Cerebrovascular dementia showed lower mean CBF value compared with non-demented group. (2) Regional CBF of bilateral frontal areas and affected basal ganglia were significantly reduced than occipital area in the dementia group. (3) A comparison of regional CBF and the Hasegawa's dementia score revealed a statistically significant correlation at the bilateral frontal areas in the dementia group. It is possible that measuring the regional CBF quantitatively by IMP-SPECT is useful for clinical analysis of vascular dementia. (author)

  15. Single photon emission computed tomography using a regularizing iterative method for attenuation correction

    International Nuclear Information System (INIS)

    Soussaline, Francoise; Cao, A.; Lecoq, G.

    1981-06-01

    An analytically exact solution to the attenuated tomographic operator is proposed. Such a technique called Regularizing Iterative Method (RIM) belongs to the iterative class of procedures where a priori knowledge can be introduced on the evaluation of the size and shape of the activity domain to be reconstructed, and on the exact attenuation distribution. The relaxation factor used is so named because it leads to fast convergence and provides noise filtering for a small number of iteractions. The effectiveness of such a method was tested in the Single Photon Emission Computed Tomography (SPECT) reconstruction problem, with the goal of precise correction for attenuation before quantitative study. Its implementation involves the use of a rotating scintillation camera based SPECT detector connected to a mini computer system. Mathematical simulations of cylindical uniformly attenuated phantoms indicate that in the range of a priori calculated relaxation factor a fast converging solution can always be found with a (contrast) accuracy of the order of 0.2 to 4% given that numerical errors and noise are or not, taken into account. The sensitivity of the (RIM) algorithm to errors in the size of the reconstructed object and in the value of the attenuation coefficient μ was studied, using the same simulation data. Extreme variations of +- 15% in these parameters will lead to errors of the order of +- 20% in the quantitative results. Physical phantoms representing a variety of geometrical situations were also studied

  16. The role of single photon emission computed tomography in bone imaging.

    Science.gov (United States)

    Sarikaya, I; Sarikaya, A; Holder, L E

    2001-01-01

    Single photon emission computed tomography (SPECT) of the bone is the second most frequently performed SPECT examination in routine nuclear medicine practice, with cardiac SPECT being the most frequent. Compared with planar scintigraphy, SPECT increases image contrast and improves lesion detection and localization. Studies have documented the unique diagnostic information provided by SPECT, particularly for avascular necrosis of the femoral head, in patients with back pain, for the differential diagnosis between malignant and benign spinal lesions, in the detection of metastatic cancer in the spine, for the diagnosis of temporomandibular joint internal derangement, and for the evaluation of acute and chronic knee pain. Although less rigorously documented, SPECT is being increasingly used in all types of situations that demand more precise anatomic localization of abnormal tracer uptake. The effectiveness of bone SPECT increases with the selection of the proper collimator, which allows one to acquire adequate counts and minimize the patient-to-detector distance. Low-energy, ultrahigh-resolution or high-resolution collimation is preferred over all-purpose collimators. Multihead gamma cameras can increase the counts obtained or shorten acquisition time, making SPECT acquisitions more practical in busy departments and also increasing image quality compared with single-head cameras. Iterative reconstruction, with the use of ordered subsets estimation maximization, provides better quality images than classical filtered back projection algorithms. Three-dimensional image analysis often aids lesion localization.

  17. An x-ray-based capsule for colorectal cancer screening incorporating single photon counting technology

    Science.gov (United States)

    Lifshitz, Ronen; Kimchy, Yoav; Gelbard, Nir; Leibushor, Avi; Golan, Oleg; Elgali, Avner; Hassoon, Salah; Kaplan, Max; Smirnov, Michael; Shpigelman, Boaz; Bar-Ilan, Omer; Rubin, Daniel; Ovadia, Alex

    2017-03-01

    An ingestible capsule for colorectal cancer screening, based on ionizing-radiation imaging, has been developed and is in advanced stages of system stabilization and clinical evaluation. The imaging principle allows future patients using this technology to avoid bowel cleansing, and to continue the normal life routine during procedure. The Check-Cap capsule, or C-Scan ® Cap, imaging principle is essentially based on reconstructing scattered radiation, while both radiation source and radiation detectors reside within the capsule. The radiation source is a custom-made radioisotope encased in a small canister, collimated into rotating beams. While traveling along the human colon, irradiation occurs from within the capsule towards the colon wall. Scattering of radiation occurs both inside and outside the colon segment; some of this radiation is scattered back and detected by sensors onboard the capsule. During procedure, the patient receives small amounts of contrast agent as an addition to his/her normal diet. The presence of contrast agent inside the colon dictates the dominant physical processes to become Compton Scattering and X-Ray Fluorescence (XRF), which differ mainly by the energy of scattered photons. The detector readout electronics incorporates low-noise Single Photon Counting channels, allowing separation between the products of these different physical processes. Separating between radiation energies essentially allows estimation of the distance from the capsule to the colon wall, hence structural imaging of the intraluminal surface. This allows imaging of structural protrusions into the colon volume, especially focusing on adenomas that may develop into colorectal cancer.

  18. An ASIC for fast single photon counting in the LHCb RICH upgrade

    Science.gov (United States)

    Gotti, C.

    2017-03-01

    The LHCb experiment will be upgraded during the second LHC long shutdown (years 2019-2020) to operate at higher luminosity. The new triggerless architecture of LHCb requires data from the entire detector to be read out at 40 MHz. The basic element of the front-end electronics of the Ring Imaging Cherenkov (RICH) detector upgrade is the "Elementary Cell" (EC), a readout system for multianode photomultiplier tubes designed to minimise parasitic capacitance at the anodes, to obtain a fast readout with low noise and low crosstalk. At the heart of the EC is the CLARO, an 8 channel, low power and radiation hard front-end ASIC designed in 0.35 μm CMOS technology. Each channel compares the charge signals from the photomultiplier anodes with a programmable threshold, and gives a digital pulse at the output when the threshold is exceeded. Baseline recovery occurs in less than 25 ns for typical single photon signals. In the LHCb RICH upgrade environment, the chips will have to withstand radiation up to a total ionising dose of 2 kGy (200 krad) and neutron and hadron fluences up to 03×112 cm-2 and following irradiation, the chips have been shown to tolerate such doses with a margin of safety.

  19. Thallium-201 single-photon emission tomography in the treatment follow-up of nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Togawa, Takashi [Chiba Cancer Center Hospital (Japan). Div. of Nuclear Medicine; Yui, Nobuharu [Chiba Cancer Center Hospital (Japan). Div. of Nuclear Medicine; Kinoshita, Fujimi [Chiba Cancer Center Hospital (Japan). Div. of Nuclear Medicine; Yanagisawa, Masamichi [Chiba Cancer Center Hospital (Japan). Div. of Nuclear Medicine; Hatano, Kazuo [Chiba Cancer Center Hospital (Japan). Div. of Radiotherapy; Sekiya, Yuichi [Chiba Cancer Center Hospital (Japan). Div. of Radiotherapy; Shimada, Fumiyuki [Chiba Cancer Center Hospital (Japan). Div. of Head and Neck Surgery; Omura, Ken [Chiba Cancer Center Hospital (Japan). Div. of Head and Neck Surgery; Takeuchi, Yousuke [Chiba Cancer Center Hospital (Japan). Div. of Head and Neck Surgery; Katahashi, Tatsuaki [Dept. of Otorhinolaryngology, School of Medicine, Chiba Univ. (Japan)

    1997-03-01

    In order to assess the usefulness of thallium-201 single-photon emission tomography (SPET) in the treatment follow-up of nasopharyngeal carcinoma (NPC), a total of 75 {sup 201}Tl SPET studies were performed in 18 patients with histologically proven NPC. The findings were compared with those of magnetic resonance imaging (MRI) before and after therapy. Four patients received radiotherapy alone while the other 14 received concurrent chemo-radiotherapy. Treatment response was classified as complete (CR) or partial (PR) based on the findings of MRI and {sup 201}Tl SPET. Intense {sup 201}Tl uptake by the tumour was seen in all 18 patients before treatment. After treatment, MRI showed seven CRs and 11 PRs, whereas {sup 201}Tl SPET showed 13 CRs and five PRs. In 12 patients, the results of {sup 201}Tl SPET were in agreement with those of MRI. In six patients MRI showed PR but {sup 201}Tl showed CR. Follow-up (mean 10.6 months) MRI and {sup 201}Tl SPET studies of these six patients revealed that tumour gradually decreased and finally vanished in three patients. This preliminary study indicates that {sup 201}Tl SPET has potential in the assessment of early response to treatment of patients with NPC when compared with MRI. (orig.)

  20. Brain blood flow studies with single photon emission computed tomography in patients with plateau waves

    International Nuclear Information System (INIS)

    Hayashi, Minoru; Kobayashi, Hidenori; Kawano, Hirokazu; Handa, Yuji; Noguchi, Yoshiyuki; Shirasaki, Naoki; Hirose, Satoshi

    1986-01-01

    The authors studied brain blood flow with single photon emission computed tomography (SPECT) in two patients with plateau waves. The intracranial pressure and blood pressure were also monitored continuously in these patients. They included one patient with brain-tumor (rt. sphenoid ridge meningioma) and another with hydrocephalus after subarachnoid hemorrhage due to rupture of lt. internal carotid aneurysm. The intracranial pressure was monitored through an indwelling ventricular catheter attached to a pressure transducer. The blood pressure was recorded through an intraarterial catheter placed in the dorsalis pedis artery. Brain blood flow was studied with Headtome SET-011 (manufactured by Shimazu Co., Ltd.). For this flow measurement study, an intravenous injection of Xenon-133 of about 30 mCi was given via an antecubital vein. The position of the slice for the SPECT was selected so as to obtain information not only from the cerebral hemisphere but also from the brain stem : a cross section 25 deg over the orbito-meatal line, passing through the inferior aspect of the frontal horn, the basal ganglia, the lower recessus of the third ventricle and the brain stem. The results indicated that, in the cerebral hemisphere, plateau waves were accompanied by a decrease in blood flow, whereas, in the brain stem, the blood flow showed little change during plateau waves as compared with the interval phase between two plateau waves. These observations may explain why there is no rise in the blood pressure and why patients are often alert during plateau waves. (author)

  1. Estimation of 99mTc-dimercaptosuccinic acid renal uptake using single photon emission computed tomography

    International Nuclear Information System (INIS)

    Ohishi, Yukihiko; Machida, Toyohei; Kido, Akira

    1986-01-01

    Renal function was assessed by measurement of 99m Tc-dimercaptosuccinic acid (DMSA) uptake by the kidney based on the transectional tomographic image obtained by single photon emission computed tomography (SPECT). The renal uptake was expressed as percentage of the total radioactivity detected in the kidney, the volume of which was measured by convolution method, against the amount dosed. Absorption was corrected by GE-STAR method using cut off level of 42 %. In order to determine normal range, measurement was made for 40 kidneys of each of 10 male and female volunteers confirmed of having normal kidneys both morphologically and functionally. The average volume of the kidney was 220.4 ml for the right and 239.3 ml for the left for males, and 205.9 ml and 236.5 ml, respectively for females. The renal uptake of radioactivity (at 2 h after injection), was 26.8 % for the right and 27.6 % for the left for males, with corresponding figures for females being 26.4 % and 27.9 %, respectively. Distribution range of renal volume and renal uptake was obtained by bivariate analysis with 90 % and 95 % probability. From these results, our method of renal function determination based on renal uptake of 99m Tc-DMSA obtained from renal transactional tomogram by SPECT is considered to be accurate and potentially useful for clinical purpose. (author)

  2. Enhanced single-photon emission from a diamond–silver aperture

    KAUST Repository

    Choy, Jennifer T.

    2011-10-09

    Solid-state quantum emitters, such as the nitrogen-vacancy centre in diamond, are robust systems for practical realizations of various quantum information processing protocols2-5 and nanoscale magnetometry schemes6,7 at room temperature. Such applications benefit from the high emission efficiency and flux of single photons, which can be achieved by engineering the electromagnetic environment of the emitter. One attractive approach is based on plasmonic resonators8-13, in which sub-wavelength confinement of optical fields can strongly modify the spontaneous emission of a suitably embedded dipole despite having only modest quality factors. Meanwhile, the scalability of solid-state quantum systems critically depends on the ability to control such emitterg-cavity interaction in a number of devices arranged in parallel. Here, we demonstrate a method to enhance the radiative emission rate of single nitrogen-vacancy centres in ordered arrays of plasmonic apertures that promises greater scalability over the previously demonstrated bottom-up approaches for the realization of on-chip quantum networks. © 2011 Macmillan Publishers Limited. All rights reserved.

  3. Single Photon Detection with Semiconductor Pixel Arrays for Medical Imaging Applications

    CERN Document Server

    Mikulec, B

    2000-01-01

    This thesis explores the functioning of a single photon counting pixel detector for X-ray imaging. It considers different applications for such a device, but focuses mainly on the field of medical imaging. The new detector comprises a CMOS read-out chip called PCC containing 4096 identical channels each of which counts X-ray hits. The conversion of the X-rays to electric charge takes place in a semiconductor sensor which is segmented into 4096 matching square diodes of side length 170 um, the 'pixels'. The photon counting concept is based on setting a threshold in energy above which a hit is registered. The immediate advantages are the elimination of background and the in principle unlimited dynamic range. Moreover, this approach allows the use of an electronic shutter for arbitrary measurement periods. As the device was intended for operation in the energy range of ~10-70 keV, gallium arsenide was selected as the preferred sensor material. The development of this detector followed on from about 10 years of r...

  4. Cone beam tomography of the heart using single-photon emission-computed tomography

    International Nuclear Information System (INIS)

    Gullberg, G.T.; Christian, P.E.; Zeng, G.L.; Datz, F.L.; Morgan, H.T.

    1991-01-01

    The authors evaluated cone beam single-photon emission-computed tomography (SPECT) of the heart. A new cone beam reconstruction algorithm was used to reconstruct data collected from short scan acquisitions (of slightly more than 180 degrees) of a detector anteriorally traversing a noncircular orbit. The less than 360 degrees acquisition was used to minimize the attenuation artifacts that result from reconstructing posterior projections of 201T1 emissions from the heart. The algorithm includes a new method for reconstructing truncated projections of background tissue activity that eliminates reconstruction ring artifacts. Phantom and patient results are presented which compare a high-resolution cone beam collimator (50-cm focal length; 6.0-mm full width at half maximum [FWHM] at 10 cm) to a low-energy general purpose (LEGP) parallel hole collimator (8.2-mm FWHM at 10 cm) which is 1.33 times more sensitive. The cone beam tomographic results are free of reconstruction artifacts and show improved spatial and contrast resolution over that obtained with the LEGP parallel hole collimator. The limited angular sampling restrictions and truncation problems associated with cone beam tomography do not deter from obtaining diagnostic information. However, even though these preliminary results are encouraging, a thorough clinical study is still needed to investigate the specificity and sensitivity of cone beam tomography

  5. Effects of atmospheric turbulence on the single-photon receiving efficiency and the performance of quantum channel with the modified approximate elliptic-beam model assumption

    Science.gov (United States)

    Wang, Xiao-yang; Zhao, Nan; Chen, Nan; Zhu, Chang-hua; Pei, Chang-xing

    2018-01-01

    In free space quantum channel, with the introduction and implementation of the satellite-ground link transmission, the researches of single-photon transmission have attracted great interest. We propose a single-photon receiving model and analyze the influence of the atmospheric turbulence on the single-photon transmission. We obtain the relationship between single-photon receiving efficiency and atmospheric turbulence, and analyze the influence of the atmospheric turbulence on the quantum channel performance by the single-photon counting. Finally, we present a reasonable simulation analysis. Simulation results show that as the strength of the atmospheric fluctuations increases, the counting distribution gradually broadens, and the utilization of quantum channel drops. Furthermore, the key generation rate and transmission distance decreases sharply in the case of strong turbulence.

  6. Fundamental analysis of activation study using single-photon-emission CT

    Energy Technology Data Exchange (ETDEWEB)

    Tanizaki, Yoshio; Makishita, Hideo; Miyasaka, Motomaro (Kakeyu Hospital, Maruko, Nagano (Japan)); Kasuga, Toshio; Yokoo, Akira; Katoh, Shigeki; Toriyama, Toshihide; Sugita, Kenichiro

    1984-06-01

    The clinical significance of cerebral-blood-flow (CBF) measurement in the diagnosis and treatment of occlusive cerebro-vascular disease is well known. Previous reports using two-dimensional CBF measurement stressed the clinical importance of the activation study. We studied the reproducibility of CBF measurement and the effect of activation using a Tomomatic 64 apparatus (Medimatic Inc., Denmark) - single-photon-emission CT (SPECT) - and the Xe-133 inhalation method. The following points were examined: I. Reproducibility: (1) The influence of the remaining Xe-133 activity (inhaled during the first measurement) on the second measurement. (2) The reproducibility of the mean hemispheric cerebral blood flow (HEM), the mean regional cerebral blood flow (rCBF), and the CBF distribution pattern. II. Activation study: (1) induced hypertension; (2) induced hypercapnia. The results obtained were as follows: I-(1) The remaining Xe-133 activity decreased monoexponentially from 4 min after the end of inhalation, and it became 7.7% after 32 min. The observation of the original SPECT images revealed that the Xe-133 activity in the brain remaining after 32 min was about 30% of the total remaining radioactivity. This result indicated that at least 30 min was necessary between the first and second measurements. I-(2) The mean value of the intermeasurement correlation coefficient of HEM-and rCBF in 16 subjects (5 healthy volunteers and 11 patients) was 0.92. The CBF distribution pattern at two successive measurements showed a good reproducibility. II. The locations of the disturbed autoregulation and disturbed vascular reactivity to CO/sub 2/ were determined by this method. The clinical significance of the activation study was proved by fundamental and clinical examinations.

  7. Rigid motion correction of dual opposed planar projections in single photon imaging

    Science.gov (United States)

    Angelis, G. I.; Ryder, W. J.; Gillam, J. E.; Boisson, F.; Kyme, A. Z.; Fulton, R. R.; Meikle, S. R.; Kench, P. L.

    2017-05-01

    Awake and/or freely moving small animal single photon emission imaging allows the continuous study of molecules exhibiting slow kinetics without the need to restrain or anaesthetise the animals. Estimating motion free projections in freely moving small animal planar imaging can be considered as a limited angle tomography problem, except that we wish to estimate the 2D planar projections rather than the 3D volume, where the angular sampling in all three axes depends on the rotational motion of the animal. In this study, we hypothesise that the motion corrected planar projections estimated by reconstructing an estimate of the 3D volume using an iterative motion compensating reconstruction algorithm and integrating it along the projection path, will closely match the true, motion-less, planar distribution regardless of the object motion. We tested this hypothesis for the case of rigid motion using Monte-Carlo simulations and experimental phantom data based on a dual opposed detector system, where object motion was modelled with 6 degrees of freedom. In addition, we investigated the quantitative accuracy of the regional activity extracted from the geometric mean of opposing motion corrected planar projections. Results showed that it is feasible to estimate qualitatively accurate motion-corrected projections for a wide range of motions around all 3 axes. Errors in the geometric mean estimates of regional activity were relatively small and within 10% of expected true values. In addition, quantitative regional errors were dependent on the observed motion, as well as on the surrounding activity of overlapping organs. We conclude that both qualitatively and quantitatively accurate motion-free projections of the tracer distribution in a rigidly moving object can be estimated from dual opposed detectors using a correction approach within an iterative reconstruction framework and we expect this approach can be extended to the case of non-rigid motion.

  8. Fast detection of narcotics by single photon ionization mass spectrometry and laser ion mobility spectrometry

    Science.gov (United States)

    Laudien, Robert; Schultze, Rainer; Wieser, Jochen

    2010-10-01

    In this contribution two analytical devices for the fast detection of security-relevant substances like narcotics and explosives are presented. One system is based on an ion trap mass spectrometer (ITMS) with single photon ionization (SPI). This soft ionization technique, unlike electron impact ionization (EI), reduces unwanted fragment ions in the mass spectra allowing the clear determination of characteristic (usually molecular) ions. Their enrichment in the ion trap and identification by tandem MS investigations (MS/MS) enables the detection of the target substances in complex matrices at low concentrations without time-consuming sample preparation. For SPI an electron beam pumped excimer light source of own fabrication (E-Lux) is used. The SPI-ITMS system was characterized by the analytical study of different drugs like cannabis, heroin, cocaine, amphetamines, and some precursors. Additionally, it was successfully tested on-site in a closed illegal drug laboratory, where low quantities of MDMA could be directly detected in samples from floors, walls and lab equipments. The second analytical system is based on an ion mobility (IM) spectrometer with resonant multiphoton ionization (REMPI). With the frequency quadrupled Nd:YAG laser (266 nm), used for ionization, a selective and sensitive detection of aromatic compounds is possible. By application of suited aromatic dopants, in addition, also non-aromatic polar compounds are accessible by ion molecule reactions like proton transfer or complex formation. Selected drug precursors could be successfully detected with this device as well, qualifying it to a lower-priced alternative or useful supplement of the SPI-ITMS system for security analysis.

  9. Phantom evaluation of simultaneous thallium-201/technetium-99m acquisition in single-photon emission tomography

    International Nuclear Information System (INIS)

    Cao Zongjian; Chen, C.C.; Maunoury, C.; Holder, L.E.; Abraham, T.C.; Tehan, A.

    1996-01-01

    This study investigated downscatter effects in cardiac single-photon emission tomographic studies with simultaneous thallium-201/technetium-99m acquisition, and evaluated a previously proposed subtraction technique for downscatter compensation. Ten studies were carried out with different defect sizes and locations and varying activity distributions using four energy windows: 70±10% keV, 140±10% keV, 100±10% KeV, and 103±16% keV. The subtraction technique used the 100- or 103-keV data to remove scattered 99m Tc counts from the 70-keV data. The size and contrast of infarcts in the dual-isotope 70-keV image were artificially decreased compared to those in the 140-keV image, caused by scattered 99m Tc counts that were comparable to the primary 201 Tl counts in the 70-keV window. The subtraction technique produced larger defects and more heterogeneous activity in the myocardial wall in dual-isotope 70-keV images compared to the corresponding 201 Tl-only images. These artifacts were caused by the markedly different spatial distributions of scattered 99m Tc counts in the 100-keV (or 103-keV) window as compared with the 70-keV window. It is concluded that scattered 99m Tc photons may cause overestimation of ischemia and myocardial viability in simultaneous dual-isotope patient studies. The proposed subtraction technique was inaccurate and produced image artifacts. Adequate downscatter compensation methods must be developed before applying simultaneous 201 Tl/ 99m Tc acquisition in clinical practice. (orig.). With 6 figs., 3 tabs

  10. Imaging of dopamine transporters in rats using high-resolution pinhole single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Booij, Jan; Bruin, Kora de; Habraken, Jan B.A. [Department of Nuclear Medicine, F2N, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Voorn, Pieter [Department of Anatomy, Vrije Universiteit Medical Center, Amsterdam (Netherlands)

    2002-09-01

    To date, the vast majority of investigations on the dopaminergic system in small animals have been in vitro studies. In comparison with in vitro studies, single-photon emission tomography (SPET) or positron emission tomography (PET) imaging of the dopaminergic system in small animals has the advantage of permitting repeated studies within the same group of animals. Dopamine transporter imaging is a valuable non-invasive tool with which to investigate the integrity of dopaminergic neurons. The purpose of this study was to investigate the feasibility of assessing dopamine transporter density semi-quantitatively in rats using a recently developed high-resolution pinhole SPET system. This system was built exclusively for imaging of small animals. In this unique single-pinhole system, the animal rotates instead of the collimated detector. The system has proven to have a high spatial resolution. We performed SPET imaging with [{sup 123}I]FP-CIT to quantify striatal dopamine transporters in rat brain. In all seven studied control rats, symmetrical striatal binding to dopamine transporters was seen 2 h after injection of the radiotracer, with striatal-to-cerebellar binding ratios of approximately 3.5. In addition, test/retest variability of the striatal-to-cerebellar binding ratios was studied and found to be 14.5%. Finally, in unilaterally 6-hydroxydopamine-lesioned rats, striatal binding was only visible on the non-lesioned side. Quantitative analysis revealed that striatal-to-cerebellar SPET ratios were significantly lower on the lesioned (mean binding ratio 2.2{+-}0.2) than on the non-lesioned (mean ratio 3.1{+-}0.4) side. The preliminary results of this study indicate that semi-quantitative assessment of striatal dopamine transporter density using our recently developed high-resolution single-pinhole SPET system is feasible in living rat brain. (orig.)

  11. Effect of caffeine on ischemia detection by adenosine single-photon emission computed tomography perfusion imaging.

    Science.gov (United States)

    Zoghbi, Gilbert J; Htay, Thien; Aqel, Raed; Blackmon, Linda; Heo, Jaekyeong; Iskandrian, Ami E

    2006-06-06

    The purpose of this research was to study the effect of one cup of coffee taken 1 h before adenosine stress on the results of myocardial perfusion imaging. Caffeine is believed to attenuate the coronary hyperemic response to adenosine by competitive blockade of the A2a receptor. Caffeine is commonly withheld before adenosine single-photon emission computed tomography (SPECT) perfusion imaging so as not to mask ischemia detection. We studied the effect of one 8-oz cup of coffee taken 1 h before adenosine stress in patients who had demonstrable reversible defects on adenosine SPECT perfusion imaging performed while off caffeine. There were 22 men and 8 women, age 64 +/- 9 years. The blood level of caffeine 1 h after intake was 3.1 +/- 1.6 mg/l. There were two patients with ST-segment depression before and one after caffeine intake (p = NS). The summed stress score (SSS) based on 17 segments (scale of 0 to 3, 3 being normal) was 44 +/- 5 before and 45 +/- 5 after caffeine (p = NS). The summed difference score was 3.8 +/- 1.9 before and. 3.9 +/- 2.3 after caffeine (p = NS), reflecting that around 50% of the perfusion abnormality was reversible before and after caffeine. Using polar maps, the perfusion abnormality was 12 +/- 10% at baseline and 12 +/- 10% after caffeine (p = NS) in agreement with SSS. The left ventricular ejection fraction by gated SPECT was 50 +/- 13% at baseline and 51 +/- 13 % after caffeine (p = NS). A cup of coffee does not mask the presence or severity of reversible defects induced by adenosine SPECT imaging.

  12. Effectiveness of revascularization surgery evaluated by proton magnetic resonance spectroscopy and single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Uno, Masaaki; Ueda, Shin; Hondo, Hideki; Matsumoto, Keizo; Harada, Masafumi [Tokushima Univ. (Japan). School of Medicine

    1996-08-01

    Proton magnetic resonance spectroscopy (MRS) and single photon emission computed tomography (SPECT) were used to evaluate chronic ischemic regions in 26 stroke patients before and 1, 3, and 6 months after revascularization surgery. The volume of interest for proton MRS was placed in an area including part of the frontal and temporal opercula, insular cortex, and basal ganglia. Twenty healthy volunteers served as controls for proton MRS. Patients were divided into three groups according to the preoperative proton MRS. Group A (n=12) had significantly lower N-acetylaspartate/choline (NAA/Cho) and N-acetylaspartate/creatine (NAA/Cr) ratios on the operative side compared to those on the contralateral side, and also lower than those in normal subjects. In seven patients in Group A, postoperative serial proton MRS demonstrated no recovery of these ratios on the operative side. However, proton MRS of the other five patients indicated gradual improvement in these ratios on the operative side at 3 to 6 months after surgery, and SPECT indicated an increase in cerebral blood flow on the operative side in four of these five patients. In Group B (n=9), proton MRS and SPECT showed no laterality before revascularization and no remarkable change during the postoperative course. In Group C (n=5), NAA/Cho or NAA/Cr decreased on the contralateral side preoperatively. Two patients showed fluctuating values of NAA/Cho or NAA/Cr during the postoperative period. Serial proton MRS and SPECT Studies may be useful for the evaluation of revascularization surgery on ischemic regions. The efficacy of revascularization surgery on the metabolism may appear gradually within 3-6 months. (author)

  13. Attenuation correction in pulmonary and myocardial single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Almquist, H

    2000-01-01

    The objective was to develop and validate methods for single photon emission computed tomography, SPECT, allowing quantitative physiologic and diagnostic studies of lung and heart. A method for correction of variable attenuation in SPECT, based on transmission measurements before administration of an isotope to the subject, was developed and evaluated. A protocol based upon geometrically well defined phantoms was developed. In a mosaic pattern phantom count rates were corrected from 39-43% to 101-110% of reference. In healthy subjects non-gravitational pulmonary perfusion gradients observed without attenuation correctionwere artefacts caused by attenuation. Pulmonary density in centre of right lung, obtained from the transmission measurement, was 0.28 {+-} 0.03 g/ml in normal subjects. Mean density was lower in large lungs compared to smaller ones. We also showed that regional ventilation/perfusion ratios could be measured with SPECT, using the readily available tracer {sup 133}Xe. Because of the low energy of {sup 133}Xe this relies heavily upon attenuation correction. A commercially available system for attenuation correction with simultaneous emission and transmission, considered to improve myocardial SPECT, performed erroneously. This could lead to clinical misjudgement. We considered that manufacturer-independent pre-clinical tests are required. In a test of two other commercial systems, based on different principles, an adapted variant of our initial protocol was proven useful. Only one of the systems provided correct emission count rates independently on phantom configuration. Errors in the other system were related to inadequate compensation of the influence of emission activity on the transmission study.

  14. Single photon emission computed tomography scanning: A predictor of outcome in vegetative state of head injury

    Directory of Open Access Journals (Sweden)

    Pralaya Nayak

    2011-01-01

    Full Text Available Background: Neurotrauma is one of the most important causes of death and disability. Some of the severely head injured patients, failed to show significant improvement despite aggressive neurosurgical management and ended up in a vegetative state. Aims: To assess the outcome at six months and one year using Glasgow outcome scale (GOS, in this prospective study on patients with severe head injury, who remained vegetative at one month. Materials and Methods: This prospective study was carried out in the department of Neurosurgery, All India Institute of Medical Sciences (AIIMS, New Delhi, over a period of a year and a half (March 2002 through July 2003. Materials and Methods: In patients with severe head injury (GCS < 8, post resuscitation, neurological assessment was done with Glasgow coma scale (GCS, pupillary light reflex, doll′s eye movement and cold caloric test in all cases. Fifty patients, who remained vegetative post injury according to the criteria of Jennett and Plum, at one month, were considered for the study. Brain SPECT (Single Photon Emission Computed T omography Scanning was carried out in selected cases. Statistical analysis: Data analysis was done by Pearson′s chi-square test on computer software SPSS, Version 10 (California, USA. Results: Patients with preserved brainstem reflex and with no perfusion defect on SPECT scan had statistically significant favorable outcome. More than 40% of vegetative patients regained consciousness by the end of one year, of whom 24% had favorable outcome in the form of moderate disability and good recovery. Conclusion: SPECT is better than computed tomography/magnetic resonance imaging (CT/MRI as it assesses the cerebral perfusion and functional injury rather than detecting the lesions only. Further study with a control group is necessary to establish the role of SPECT in head injury.

  15. [Myocardial single photon emission tomography imaging of reporter gene expression in rabbits].

    Science.gov (United States)

    Liu, Ying; Lan, Xiao-li; Zhang, Liang; Wu, Tao; Jiang, Ri-feng; Zhang, Yong-xue

    2009-06-01

    To explore the feasibility of single photon emission computed tomography (SPECT) detection of heart reporter gene expression and observed the optimal transfecting titer and imaging time by using herpes simplex virus 1-thymidine kinase (HSV1-tk) as reporter gene and 131I-2'-fluoro-2'-deoxy-1-beta-D-arabinofuranosyl-5-iodouracil (131I-FIAU) as reporter probe in rabbit myocardium. The recombinant Ad-tk carrying HSV1-tk gene and adenovirus (Ad) as vector was constructed and intramyocardially injected to rabbits at various concentrations (1 x 10(9) pfu, 5 x 10(8) pfu, 1 x 10(8) pfu, 5 x 10(7) pfu, 1 x 10(7) pfu). Two days later, rabbits were injected with 600 microCi 131I-FIAU in ear-margin vein and then underwent SPECT myocardium imaging for detection of HSV1-tk expression at 6 h, 24 h, 48 h and 72 h after injection, rabbits with 1 x 10(9) pfu Ad-tk injection were imaged at 96 h and 120 h. Rabbits were sacrificed after imaging and the total myocardial 131I-FIAU accumulation was quantified in percent of injected dose per gram myocardium (% ID/g). The myocardial Ad-tk expression was determined with RT-PCR. Reporter gene was detected by SPECT imaging in the injection site while not detected in the control myocardium and site remote from injection. RT-PCR results also evidenced HSV1-tk express in the injection site. The SPECT target/nontarget ratio was correlated with ex vivo gamma-counting (r2 = 0.933, Ppfu by SPECT imaging. The cardiac SPECT reporter gene imaging with HSV1-tk as reporter gene and 131I-FIAU as reporter probe is feasible.

  16. Different thallium-201 single-photon emission tomographic patterns in benign and aggressive meningiomas

    International Nuclear Information System (INIS)

    Tedeschi, E.; Soricelli, A.; Brunetti, A.; Romano, M.; Bucciero, A.; Iaconetta, G.; Alfieri, A.; Postiglione, A.; Salvatore, M.

    1996-01-01

    To evaluate the possibility of preoperatively obtaining an index of aggressiveness for intracranial meningiomas, we prospectively studied 22 patients with computed tomographic or magnetic resonance imaging evidence of meningeal tumour, using single-photon emission tomography (SPET) of the brain and thallium-201 ( 201 Tl). On a brain-dedicated SPET scanner, a rapid acquisition protocol with early, short scans was started simultaneously with the intravenous administration of 111 MBq 201 Tl, covering the initial intratumoral distribution of the tracer. Twenty minutes post injection, a delayed SPET scan was also obtained. On the reconstructed and attenuation-corrected images we calculated the 201 Tl concentration in tumour and normal contralateral brain tissue, and compared intratumoral tracer concentration in the initial and the final part of the rapid acquisition protocol. Benign and malignant meningiomas were classified as such based on histological examination. In malignant lesions, the ratio of the 201 Tl concentration at 2-4 min post injection to that at 14-16 min was found to be significantly higher than in non-aggressive neoplasms (mean±1 SD: 1.14±0.31 and 0.56±0.13, respectively, P 201 Tl concentration values at 2-4 and at 14-16 min. Our findings suggest that the comparative assessment of intratumoral 201 Tl concentration at 2-4 and at 14-16 min post injection could provide a fast, simple method to differentiate preoperatively intracranial meningiomas with different biological behaviour. (orig.). With 3 figs., 1 tab

  17. Regional cerebral blood flow in status epileptics measured by single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Ichiseki, Hajime; Terashi, Akiro; Hamamoto, Makoto; Miyazaki, Tokuzo.

    1995-01-01

    We have performed single photon emission computed tomography (SPECT) with 99m Tc-hexamethylpropylene amineoxime (HM-PAO) to evaluate regional cerebral blood flow (rCBF) in status epileptics (SE) caused by a cerebral vascular accident. In addition, we have discussed the neurophysiology of SE based on the SPECT findings. A total of sixteen patients (5 males and 11 females, average age; 78.2 years old) with SE who were suffering from prolonged consciousness disturbance were investigated. When SPECT was performed in the ictal state, there was a remarkable increase in radio isotope (RI) uptake at the focus which correlated well with EEG findings. However, in other cortical regions, basal ganglia and thalamus, there was a relatively demonstrated decrease in RI uptake compared with that of the focus. Additionally in the interictal state, we found a decrease in RI uptake in the epileptic foci and normal recovery of the RI uptake level in other cerebral regions. We speculate that these characteristic patterns of cerebral blood flow distribution shown by SPECT scans in the ictal state reflect the state of consciousness disturbance due to SE. In general, in the elderly, it is difficult to make a differential diagnosis between prolonged consciousness disturbance due to nonconvulsive SE and other diseases such as cardiovascular diseases, dehydration, metabolic disorder, etc. Nevertheless, nonconvulsive SE causes diffuse cell loss and irreversible brain damage. Therefore the elderly who have suffered from prolonged consciousness disturbance due to SE need an exact diagnosis and immediate medical treatment. When we diagnose a nonconvulsive SE, the characteristic findings of SPECT scans in the ictal state are very clear and useful. In conclusion, SPECT is a very simple and non-invasive method that demonstrates abnormalities of brain function exactly. Therefore, we should perform not only EEC but also SPECT scans when making a diagnosis of SE. (author)

  18. Reverse redistribution in dipyridamole-loading thallium-201 images using single photon emission computed tomography

    International Nuclear Information System (INIS)

    Mori, Kiyoo; Masuda, Masanosuke; Bunko, Hisashi.

    1986-01-01

    Dipyridamole was infused intravenously at a rate of 0.142 mg/kg per min for four min, and a stress image was obtained 10 min after the injection of two mCi 201 Tl. The myocardial image of Tl was analyzed by single photon emission computed tomography and its washout rate was calculated by the segmental ROI method. Myocardial function and the motion of the left ventricular wall were analyzed by 99m Tc-RBC-gated cardiac pool imaging. Reverse redistribution was noted in 27 (21.6 %) of 125 consecutive Tl dipyridamole and redistribution myocardial imaging studies. The stress image demonstrated normal perfusion (group 1) and reduced perfusion (group 2) of Tl. Group 1 consisted of 17 patients with diabetes mellitus, supraventricular arrhythmias, hypertension, and others. Group 2 consisted of 10 patients with subendocardial infarction, diabetes mellitus, and hypertension, and others. The percentage prevalence of reverse redistribution among patients with supraventricular arrhythmia was 62.5 % (five of eight patients), with subendocardial infarction 60.0 % (three of five), with hypertension 42.8 % (six of 14), and with diabetes mellitus 40.0 % (eight of 20), while in those with transmyocardial infarction and angina pectoris no reverse redistribution percentage was found. The washout rate of Tl in normal perfusion areas was 44.0 ± 12.8 %, the reverse redistribution of group 1 was 47.4 ± 12.8 %, and of group 2 was 51.2 ± 8.2 %. The washout rate of the reverse redistribution of group 2 was significantly greater than that of the normal areas. In gated cardiac pool imaging, patients in group 2 had significantly larger areas showing abnormal contraction of the left ventricular wall and significantly lower ejection fraction than did group 1. In the electrocardiogram ST segment depression was noted more frequently in group 2 than group 1. No Q wave was present in the corresponding reverse redistribution area. (J.P.N.)

  19. Prognostic value of single-photon emission tomography in acute ischaemic stroke

    International Nuclear Information System (INIS)

    Weir, C.J.; Bolster, A.A.; Tytler, S.; Murray, G.D.; Corrigall, R.S.; Adams, F.G.; Lees, K.R.

    1997-01-01

    Single-photon emission tomography (SPET) is widely used in the investigation of acute stroke. We investigated the relationship between SPET data and functional outcome in a large group of acute stroke patients. One hundred and eight patients underwent cerebral computed tomography (CT) and technetium-99m hexamethylpropylene amine oxime SPET after acute ischaemic stroke. We categorised the clinical presentation according to the Oxford classification of acute stroke. Outcome was measured 1 year after stroke using mortality and the Barthel Index for survivors. SPET scans were interpreted without reference to the clinical data using a semi-automatic technique. Three experienced observers determined the presence of luxury perfusion using suitably scaled SPET images in conjunction with the CT scan. Both SPET volume and severity of deficit were significantly negatively correlated with Barthel Index at 1 year (r s =-0.310, P s =-0.316, P s =-0.606, P s =-0.492, P 2 =0.073, df=1, P=0.79) with good functional outcome (Barthel score ≥60). Stepwise logistic regression identified Oxford classification, total deficit volume and patient's age as significant predictors of functional outcome. Overall predictive accuracy was 72%. Predictive accuracy was better in patients who received SPET within 16 h of stroke onset. SPET provides useful information about the functional outcome of acute stroke at 1 year. However, the accuracy of prediction decreases the longer SPET is delayed. Prognostication using SPET in combination with clinical assessment and other investigations may also be considered. (orig.). With 3 figs., 4 tabs

  20. Voxel-Based Spatial Filtering Method for Canopy Height Retrieval from Airborne Single-Photon Lidar

    Directory of Open Access Journals (Sweden)

    Hao Tang

    2016-09-01

    Full Text Available Airborne single-photon lidar (SPL is a new technology that holds considerable potential for forest structure and carbon monitoring at large spatial scales because it acquires 3D measurements of vegetation faster and more efficiently than conventional lidar instruments. However, SPL instruments use green wavelength (532 nm lasers, which are sensitive to background solar noise, and therefore SPL point clouds require more elaborate noise filtering than other lidar instruments to determine canopy heights, particularly in daytime acquisitions. Histogram-based aggregation is a commonly used approach for removing noise from photon counting lidar data, but it reduces the resolution of the dataset. Here we present an alternate voxel-based spatial filtering method that filters noise points efficiently while largely preserving the spatial integrity of SPL data. We develop and test our algorithms on an experimental SPL dataset acquired over Garrett County in Maryland, USA. We then compare canopy attributes retrieved using our new algorithm with those obtained from the conventional histogram binning approach. Our results show that canopy heights derived using the new algorithm have a strong agreement with field-measured heights (r2 = 0.69, bias = 0.42 m, RMSE = 4.85 m and discrete return lidar heights (r2 = 0.94, bias = 1.07 m, RMSE = 2.42 m. Results are consistently better than height accuracies from the histogram method (field data: r2 = 0.59, bias = 0.00 m, RMSE = 6.25 m; DRL: r2 = 0.78, bias = −0.06 m and RMSE = 4.88 m. Furthermore, we find that the spatial-filtering method retains fine-scale canopy structure detail and has lower errors over steep slopes. We therefore believe that automated spatial filtering algorithms such as the one presented here can support large-scale, canopy structure mapping from airborne SPL data.

  1. Proton magnetic resonance spectroscopy and single photon emission CT in patients with olivopontocerebellar atrophy

    International Nuclear Information System (INIS)

    Ikuta, Naomi

    1998-01-01

    Using proton magnetic resonance spectroscopy ( 1 H-MRS) and single photon emission CT (SPECT), the cerebellum of patients with olivopontocerebellar atrophy (OPCA) and of age-matched control subjects was studied. A spectrum was collected from a 27 cm 3 (3 x 3 x 3 cm) voxel in the cerebellum containing white and gray matters in order to measure the distribution and relative signal intensities of N-acetylaspartate (NAA), creatine (Cre) and choline (Cho). In the cerebellum of the patients with OPCA, mean NAA/Cre ratios for OPCA patients were significantly decreased compared with normal control subjects (OPCA, 1.01±0.247; controls, 1.526±0.144: p<0.001). Mean NAA/Cho ratios for OPCA patients were slightly decreased (OPCA, 1.285±0.228; controls 1.702±0.469: p<0.06). Cho/Cre ratios valued in the cerebellum of OPCA patients were not significantly different from those in normal controls (OPCA, 0.793±0.186; controls, 0.946±0.219). The ratio of RI count in the cerebellum to that in the occipital lobe was significantly decreased in OPCA patients (OPCA, 0.947±0.096; controls, 1.06±0.063: p<0.01). Cerebellar signs were assessed including gait ataxia, limb ataxia, dysarthria, saccadic pursuit, and nystagmus separately or in combination. In patients with more severe ataxic gait and dysarthria, MRS revealed slightly lowered NAA/Cre ratio. There was no significant correlation between NAA/Cre ratio and severity of other clinical signs. The MRS and SPECT findings give a confirmative evidence of hypofunction in cerebellum of patients with OPCA. (author)

  2. Ultra-compact 32-channel system for time-correlated single-photon counting measurements

    Science.gov (United States)

    Antonioli, S.; Cuccato, A.; Miari, L.; Labanca, I.; Rech, I.; Ghioni, M.

    2013-05-01

    Modern Time-Correlated Single-Photon Counting applications require to detect spectral and temporal fluorescence data simultaneously and from different areas of the analyzed sample. These rising quests have led the development of multichannel systems able to perform high count rate and high performance analysis. In this work we describe a new 32-channel TCSPC system designed to be used in modern setups. The presented module consists of four independent 8-channel TCSPC boards, each of them including two 4-channel Time-Amplitude Converter arrays. These TAC arrays are built-in 0.35 μm Si-Ge BiCMOS technology and are characterized by low crosstalk, high resolution, high conversion rate and variable full-scale range. The 8-channel TCSPC board implements an 8-channel ADC to sample the TAC outputs, an FPGA to record and organize the measurement results and a USB 2.0 interface to enable real-time data transmission to and from an external PC. Experimental results demonstrate that the acquisition system ensures high performance TCSPC measurements, in particular: high conversion rate (5 MHz), good time resolution (down to 30 psFWHM with the full scale range set to 11 ns) and low differential non-linearity (rms value lower than 0.15% of the time bin width). We design the module to be very compact and, thanks to the reduced dimensions of the 8-channel TCSPC board (95×40 mm), the whole system can be enclosed in a small aluminum case (160×125×30 mm).

  3. The evaluation of surgical treatments for putaminal hemorrhage by means of single-photon-emission CT

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Mikiya; Inoue, Yoshitoshi; Hayashi, Seiji; Morinaga, Kazuo; Matsumoto, Yukihiro; Omiya, Nobuyuki; Mikami, Junichi; Sato, Hiroyuki; Okawara, Shuji (Okawara Neurosurgical Hospital, Muroran, Hokkaido (Japan))

    1992-12-01

    Twenty-two patients with mild putaminal hemorrhage (neurological grades 1 and 2) were divided into three groups. Four (conservative group) received conservative treatment. Thirteen (aspiration group) underwent CT-guided stereotactic aspiration. Four (craniotomy group) underwent microsurgical evacuation of the hematoma. Surgical treatments were performed within 6 days after the onset. We measured the cerebral blood flow (CBF) using single-photon-emission CT and the [sup 133]Xe-inhalation method. The CBF was measured at the acute stage (Days 1-7), at the subacute stage (Days 8-14), and at the chronic stage (one month after the onset). In putaminal hemorrhage with both neurological grades 1 and 2 and with 2 only, the mean hemispheric CBF (mCBF) of the hematoma and the nonhematoma side among the three groups had no significance at any stage. In each group, no improvement in the reduction of mCBF was observed. In putaminal hemorrhage with neurological grade 1 only, however, the mCBF of the hematoma side at the chronic stage was 47.8[+-]6.7 ml/100 g/min in the conservative group and 59.1[+-]7.6 ml/100 g/min in the aspiration group. This difference was statistically significant. In the aspiration group, the mCBF values of both sides and the regional CBF (rCBF)-A[center dot]L[center dot]P at the chronic stage increased significantly compared with those at the acute and subacute stage. On the other hand, in the conservative group, no improvement in the reduction of CBF at the chronic stage was observed. From the serial measurement of CBF, it was observed that, compared with conservative therapy, CT-guited stereotactic aspiration for putaminal hemorrhage with neurological grade 1 is more effective. (author).

  4. Attenuation correction in pulmonary and myocardial single photon emission computed tomography

    International Nuclear Information System (INIS)

    Almquist, H.

    2000-01-01

    The objective was to develop and validate methods for single photon emission computed tomography, SPECT, allowing quantitative physiologic and diagnostic studies of lung and heart. A method for correction of variable attenuation in SPECT, based on transmission measurements before administration of an isotope to the subject, was developed and evaluated. A protocol based upon geometrically well defined phantoms was developed. In a mosaic pattern phantom count rates were corrected from 39-43% to 101-110% of reference. In healthy subjects non-gravitational pulmonary perfusion gradients observed without attenuation correction were artefacts caused by attenuation. Pulmonary density in centre of right lung, obtained from the transmission measurement, was 0.28 ± 0.03 g/ml in normal subjects. Mean density was lower in large lungs compared to smaller ones. We also showed that regional ventilation/perfusion ratios could be measured with SPECT, using the readily available tracer 133 Xe. Because of the low energy of 133 Xe this relies heavily upon attenuation correction. A commercially available system for attenuation correction with simultaneous emission and transmission, considered to improve myocardial SPECT, performed erroneously. This could lead to clinical misjudgement. We considered that manufacturer-independent pre-clinical tests are required. In a test of two other commercial systems, based on different principles, an adapted variant of our initial protocol was proven useful. Only one of the systems provided correct emission count rates independently on phantom configuration. Errors in the other system were related to inadequate compensation of the influence of emission activity on the transmission study

  5. Proton magnetic resonance spectroscopy and single photon emission CT in patients with olivopontocerebellar atrophy

    Energy Technology Data Exchange (ETDEWEB)

    Ikuta, Naomi [Yamaguchi Univ., Ube (Japan). School of Medicine

    1998-04-01

    Using proton magnetic resonance spectroscopy ({sup 1}H-MRS) and single photon emission CT (SPECT), the cerebellum of patients with olivopontocerebellar atrophy (OPCA) and of age-matched control subjects was studied. A spectrum was collected from a 27 cm{sup 3} (3 x 3 x 3 cm) voxel in the cerebellum containing white and gray matters in order to measure the distribution and relative signal intensities of N-acetylaspartate (NAA), creatine (Cre) and choline (Cho). In the cerebellum of the patients with OPCA, mean NAA/Cre ratios for OPCA patients were significantly decreased compared with normal control subjects (OPCA, 1.01{+-}0.247; controls, 1.526{+-}0.144: p<0.001). Mean NAA/Cho ratios for OPCA patients were slightly decreased (OPCA, 1.285{+-}0.228; controls 1.702{+-}0.469: p<0.06). Cho/Cre ratios valued in the cerebellum of OPCA patients were not significantly different from those in normal controls (OPCA, 0.793{+-}0.186; controls, 0.946{+-}0.219). The ratio of RI count in the cerebellum to that in the occipital lobe was significantly decreased in OPCA patients (OPCA, 0.947{+-}0.096; controls, 1.06{+-}0.063: p<0.01). Cerebellar signs were assessed including gait ataxia, limb ataxia, dysarthria, saccadic pursuit, and nystagmus separately or in combination. In patients with more severe ataxic gait and dysarthria, MRS revealed slightly lowered NAA/Cre ratio. There was no significant correlation between NAA/Cre ratio and severity of other clinical signs. The MRS and SPECT findings give a confirmative evidence of hypofunction in cerebellum of patients with OPCA. (author)

  6. Safety of ventilation/perfusion single photon emission computed tomography for pulmonary embolism diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Le Roux, Pierre-Yves; Palard, Xavier; Robin, Philippe; Abgral, Ronan; Querellou, Solene; Salaun, Pierre-Yves [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Service de medecine nucleaire, Brest (France); Delluc, Aurelien; Couturaud, Francis [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Le Gal, Gregoire [Universite Europeenne de Bretagne, Brest (France); University of Ottawa, Ottawa Hospital Research Institute, Ottawa (Canada); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Universite de Brest, Brest (France)

    2014-10-15

    The aim of this management outcome study was to assess the safety of ventilation/perfusion single photon emission computed tomography (V/Q SPECT) for the diagnosis of pulmonary embolism (PE) using for interpretation the criteria proposed in the European Association of Nuclear Medicine (EANM) guidelines for V/Q scintigraphy. A total of 393 patients with clinically suspected PE referred to the Nuclear Medicine Department of Brest University Hospital from April 2011 to March 2013, with either a high clinical probability or a low or intermediate clinical probability but positive D-dimer, were retrospectively analysed. V/Q SPECT were interpreted by the attending nuclear medicine physician using a diagnostic cut-off of one segmental or two subsegmental mismatches. The final diagnostic conclusion was established by the physician responsible for patient care, based on clinical symptoms, laboratory test, V/Q SPECT and other imaging procedures performed. Patients in whom PE was deemed absent were not treated with anticoagulants and were followed up for 3 months. Of the 393 patients, the prevalence of PE was 28 %. V/Q SPECT was positive for PE in 110 patients (28 %) and negative in 283 patients (72 %). Of the 110 patients with a positive V/Q SPECT, 78 (71 %) had at least one additional imaging test (computed tomography pulmonary angiography or ultrasound) and the diagnosis of PE was eventually excluded in one patient. Of the 283 patients with a negative V/Q SPECT, 74 (26 %) patients had another test. The diagnosis of PE was finally retained in one patient and excluded in 282 patients. The 3-month thromboembolic risk in the patients not treated with anticoagulants was 1/262: 0.38 % (95 % confidence interval 0.07-2.13). A diagnostic management including V/Q SPECT interpreted with a diagnostic cut-off of ''one segmental or two subsegmental mismatches'' appears safe to exclude PE. (orig.)

  7. Time-correlated single-photon counting study of multiple photoluminescence lifetime components of silicon nanoclusters

    Energy Technology Data Exchange (ETDEWEB)

    Diamare, D., E-mail: d.diamare@ee.ucl.ac.uk [Department of Electronic and Electrical Engineering, University College London, Torrington Place, London, WC1E 7JE (United Kingdom); Wojdak, M. [Department of Electronic and Electrical Engineering, University College London, Torrington Place, London, WC1E 7JE (United Kingdom); Lettieri, S. [Institute for Superconductors and Innovative Materials, National Council of Research (CNR-SPIN), Via Cintia 80126, Naples (Italy); Department of Physical Sciences, University of Naples “Federico II”, Via Cintia 80126, Naples (Italy); Kenyon, A.J. [Department of Electronic and Electrical Engineering, University College London, Torrington Place, London, WC1E 7JE (United Kingdom)

    2013-04-15

    We report time-resolved photoluminescence measurements of thin films of silica containing silicon nanoclusters (Si NCs), produced by PECVD and annealed at temperatures between 700 °C and 1150 °C. While the near infrared emission of Si NCs has long been studied, visible light emission has only recently attracted interest due to its very short decay times and its recently-reported redshift with decreasing NCs size. We analyse the PL decay dynamics in the range 450–700 nm with picosecond time resolution using Time Correlated Single Photon Counting. In the resultant multi-exponential decays two dominant components can clearly be distinguished: a very short component, in the range of hundreds of picoseconds, and a nanosecond component. In this wavelength range we do not detect the microsecond component generally associated with excitonic recombination. We associate the nanosecond component to defect relaxation: it decreases in intensity in the sample annealed at higher temperature, suggesting that the contribution from defects decreases with increasing temperature. The origin of the very fast PL component (ps time region) is also discussed. We show that it is consistent with the Auger recombination times of multiple excitons. Further work needs to be done in order to assess the contribution of the Auger-controlled recombinations to the defect-assisted mechanism of photoluminescence. -- Highlights: ► We report time-resolved PL measurements of Si-Ncs embedded in SiO{sub 2} matrix. ► Net decrease of PL with increasing the annealing temperature has been observed. ► Lifetime distribution analysis revealed a multiexponential decay with ns and ps components. ► Ps components are consistent with the lifetime range of the Auger recombination times. ► No evidence for a fast direct transition at the Brillouin zone centre.

  8. Cerebral blood flow single-photon emission tomography with 123I-IMP in vascular dementia

    International Nuclear Information System (INIS)

    Kawahata, Nobuya; Gotoh, Chiharu; Yokoyama, Sakura; Daitoh, Nobuyuki

    2001-01-01

    Cerebral blood flow differences between patients with vascular dementia, patients with multiple lacunar infarction without cognitive dysfunction, and age-matched controls were examined. Thirty four patients with vascular dementia (VD) were selected from consecutive referrals to the Memory Clinic at Narita Memorial Hospital. All the patients had routine assessment including history, physical and neurological examinations, neuropsychological assessment, blood tests, EEG, head MRI, and single photon emission computed tomography (SPECT). All of them fulfilled the NINDS-AIREN diagnostic criteria for vascular dementia. Thirty nine patients with multiple lacunar infarction without cognitive dysfunction and 110 age-matched controls were included in this study. Mean cerebral blood flow (mCBF) and regional cerebral blood flow (rCBF) were measured using N-isopropyl-P- 123 I-iodoamphetamine ( 123 I-IMP) and SPECT imager. The mCBF in VD was 27.6±5.3 ml/100 g/min, while those in the control group and multiple lacunar infarction without cognitive dysfunction were 36.6±6.1 ml/100 g/min and 32.5±5.5 ml/100 g/min, respectively. The patients with VD demonstrated significantly reduced mCBF and rCBF in twenty regions including both cerebellar hemispheres as compared with those of the control group. Although there was no significant rCBF differences in bilateral inferior occipital regions and the right cerebellar hemisphere between patients with VD and multiple lacunar infarction without cognitive dysfunction, we could find significant lower rCBF in the remaining brain areas. In spite of the severity of VD, the diffuse decrease of cerebral blood flow was recognized in all patients with VD. (author)

  9. Evaluation of the ID220 single photon avalanche diode for extended spectral range of photon time-of-flight spectroscopy

    DEFF Research Database (Denmark)

    Nielsen, Otto Højager Attermann; Dahl, Anders Bjorholm; Anderson-Engels, Stefan

    , Lund University (Sweden) together with ID Quantique Inc. (Geneve, Switzerland). As such, the report does not give an introduction to PToF spectroscopy, which may be found om the Doctoral on the topic [2, 18, 1]. The report focuses on a description of the detectors ability to measure the PTo......This paper describe the performance of the ID220 single photon avalanche diode for single photon counting, and investigates its performance for photon time-of-flight (PToF) spectroscopy. At first this report will serve as a summary to the group for PToF spectroscopy at the Department of Physics......F distribution of infrared light. First, a motivation for using the ID220 for measuring PToF distribution is given, followed by a brief description of the experimental setup in which the detector was characterized. Following this, the quantification of delay using cross correlation between PToF distributions...

  10. Time-over-threshold readout to enhance the high flux capabilities of single-photon-counting detectors

    International Nuclear Information System (INIS)

    Bergamaschi, Anna; Dinapoli, Roberto; Greiffenberg, Dominic; Henrich, Beat; Johnson, Ian; Mozzanica, Aldo; Radicci, Valeria; Schmitt, Bernd; Shi, Xintian; Stoppani, Laura

    2011-01-01

    The MYTHEN photon-counting ASIC operated in time-over-threshold mode shows an innovative approach towards the development of a detector operating with very high photon intensities while maintaining the single-photon sensitivity for synchrotron radiation experiments. The MYTHEN single-photon-counting (SPC) detector has been characterized using the time-over-threshold (ToT) readout method, i.e. measuring the time that the signal produced by the detected X-rays remains above the comparator threshold. In the following it is shown that the ToT readout preserves the sensitivity, dynamic range and capability of background suppression of the SPC mode, while enhancing the count-rate capability, which is the main limitation of state-of-the-art SPC systems

  11. Time-over-threshold readout to enhance the high flux capabilities of single-photon-counting detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bergamaschi, Anna, E-mail: anna.bergamaschi@psi.ch; Dinapoli, Roberto; Greiffenberg, Dominic; Henrich, Beat; Johnson, Ian; Mozzanica, Aldo; Radicci, Valeria; Schmitt, Bernd; Shi, Xintian; Stoppani, Laura [Paul Scherrer Institut, CH-5232 Villigen (Switzerland)

    2011-11-01

    The MYTHEN photon-counting ASIC operated in time-over-threshold mode shows an innovative approach towards the development of a detector operating with very high photon intensities while maintaining the single-photon sensitivity for synchrotron radiation experiments. The MYTHEN single-photon-counting (SPC) detector has been characterized using the time-over-threshold (ToT) readout method, i.e. measuring the time that the signal produced by the detected X-rays remains above the comparator threshold. In the following it is shown that the ToT readout preserves the sensitivity, dynamic range and capability of background suppression of the SPC mode, while enhancing the count-rate capability, which is the main limitation of state-of-the-art SPC systems.

  12. Study on the performance of quantum key distribution scheme with the single photon frequency up-conversion detector

    Science.gov (United States)

    Shi, Lei; Luo, Jun Wen; Xue, Yang; Wei, Jiahua

    2017-10-01

    In order to improve the detection efficiency in QKD system, this paper has put forward a new quantum key distribution scheme based on the single photon frequency up-conversion detection technology and decoy-state BB84 protocol. A long wavelength pump light is adopted in single photon detector (SPD) to avoid the noise caused by spontaneous parametric down conversion (SPDC), thus an overall 28% detection efficiency is achieved which is five times of 4.5% in conventional InGaAs-based detectors. Moreover, the propagating distances has reached 90km and 150km with weak coherent pulse (WCP) and decoy weak coherent pulse (DWCP) respectively, which is 1.3 times and 1.05 times of the conventional InGaAs-based detectors of 70km and 140km.

  13. Searches for new physics in single-photon events and a search for charginos at the DELPHI experiment

    CERN Document Server

    Ask, S M

    2004-01-01

    A search for new physics using events with a single photon and missing energy has been made at the DELPHI experiment together with a search for charginos. The results were based on data collected up to and including the final year of 2000. An integrated luminosity of 650 pb−1 was used in the single photon analysis and 450 pb−1 in the chargino search. Center-of-mass energies up to 209 GeV were explored. Searches have been made for supersymmetry as well as for extra dimensions and non standard neutrino interactions. Since no signs of a signal have been observed in any of the searches the results have been used to set exclusion limits and to constrain the theoretical parameter spaces. The search results using single and acoplanar photon events from the four LEP experiments have also been combined within the searches for supersymmetry and extra dimensions.

  14. Time-gated single-photon detection module with 110 ps transition time and up to 80 MHz repetition rate

    Energy Technology Data Exchange (ETDEWEB)

    Buttafava, Mauro, E-mail: mauro.buttafava@polimi.it; Boso, Gianluca; Ruggeri, Alessandro; Tosi, Alberto [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); Dalla Mora, Alberto [Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy)

    2014-08-15

    We present the design and characterization of a complete single-photon counting module capable of time-gating a silicon single-photon avalanche diode with ON and OFF transition times down to 110 ps, at repetition rates up to 80 MHz. Thanks to this sharp temporal filtering of incoming photons, it is possible to reject undesired strong light pulses preceding (or following) the signal of interest, allowing to increase the dynamic range of optical acquisitions up to 7 decades. A complete experimental characterization of the module highlights its very flat temporal response, with a time resolution of the order of 30 ps. The instrument is fully user-configurable via a PC interface and can be easily integrated in any optical setup, thanks to its small and compact form factor.

  15. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...... myocardial infarction, the AUC was 0.90 (95% CI: 0.87-0.94) and in patients without prior CAD the AUC for combined CTA-CTP was 0.93 (95% CI: 0.89-0.97). For the combination of a CTA stenosis ≥50% stenosis and a CTP perfusion deficit, the sensitivity, specificity, positive predictive, and negative predicative...

  16. Interictal "patchy" regional cerebral blood flow patterns in migraine patients. A single photon emission computerized tomographic study

    DEFF Research Database (Denmark)

    Friberg, L; Olesen, J; Iversen, Helle Klingenberg

    1994-01-01

    In 92 migraine patients and 44 healthy control subjects we recorded regional cerebral blood flow (rCBF) with single photon emission computerized tomography and (133) Xe inhalation or with i.v. (99m) Tc-HMPAO. Migraine patients were studied interictally. A quantitated analysis of right-left asymme......In 92 migraine patients and 44 healthy control subjects we recorded regional cerebral blood flow (rCBF) with single photon emission computerized tomography and (133) Xe inhalation or with i.v. (99m) Tc-HMPAO. Migraine patients were studied interictally. A quantitated analysis of right...... rCBF images is insufficient to pick up abnormalities; (2) almost 50% of the migraine sufferers had abnormal rCBF/asymmetries. However, these are discrete compared with those typically seen during the aura phase of a migraine attack. One explanation to the patchy rCBF patterns might...

  17. CdSe quantum dot in vertical ZnSe nanowire and photonic wire for efficient single-photon emission

    DEFF Research Database (Denmark)

    Cremel, Thibault; Bellet-Amalric, Edith; Cagnon, Laurent

    We’ve recently demonstrated that a CdSe quantum dot (QD) in a ZnSe nanowire (NW) can emit triggered single photons up to room temperature [1]. In this contribution, we present the possibilities of enhancing the photon emission and collection in such NW-QDs structures for a realistic application...... as a single photon source. We have grown vertically oriented ZnSe NWs (with typical diameter of 10 nm) by molecular beam epitaxy on a ZnSe(111)B buffer layer. The growth of a ZnMgSe passivating shell increases the (otherwise weak) ZnSe near-band-edge luminescence by two orders of magnitude. This has allowed...

  18. [Analysis of single-photon emission computed tomography in patients with hypertensive encephalopathy complicated with previous hypertensive crisis].

    Science.gov (United States)

    Kustkova, H S

    2012-01-01

    In cerebrovascular diseases pefuzionnaya single photon emission computed tomography with lipophilic amines used for the diagnosis of functional disorders of cerebral blood flow. Quantitative calculations helps clarify the nature of vascular disease and clarify the adequacy and effectiveness of the treatment. In this modern program for SPECT ensure conduct not only as to the calculation of blood flow, but also make it possible to compute also the absolute values of cerebral blood flow.

  19. Frequency tuning of single photons from a whispering-gallery mode resonator to MHz-wide transitions

    DEFF Research Database (Denmark)

    Schunk, G.; Vogl, U.; Sedlmeir, F.

    2016-01-01

    Quantum repeaters rely on interfacing flying qubits with quantum memories. The most common implementations include a narrowband single photon matched in bandwidth and central frequency to an atomic system. Previously, we demonstrated the compatibility of our versatile source of heralded single....... Finally, we present an accurate analytical description of our observations. Providing the demonstrated flexibility in connecting various atomic transitions with telecom wavelengths, we show a promising approach to realize an essential building block for quantum repeaters....

  20. High-fidelity frequency down-conversion of visible entangled photon pairs with superconducting single-photon detectors

    International Nuclear Information System (INIS)

    Ikuta, Rikizo; Kato, Hiroshi; Kusaka, Yoshiaki; Yamamoto, Takashi; Imoto, Nobuyuki; Miki, Shigehito; Yamashita, Taro; Terai, Hirotaka; Wang, Zhen; Fujiwara, Mikio; Sasaki, Masahide; Koashi, Masato

    2014-01-01

    We experimentally demonstrate a high-fidelity visible-to-telecommunicationwavelength conversion of a photon by using a solid-state-based difference frequency generation. In the experiment, one half of a pico-second visible entangled photon pair at 780 nm is converted to a 1522-nm photon. Using superconducting single-photon detectors with low dark count rates and small timing jitters, we observed a fidelity of 0.93±0.04 after the wavelength conversion

  1. Microscopic theory of cavity-enhanced single-photon emission from optical two-photon Raman processes

    Science.gov (United States)

    Breddermann, Dominik; Praschan, Tom; Heinze, Dirk; Binder, Rolf; Schumacher, Stefan

    2018-03-01

    We consider cavity-enhanced single-photon generation from stimulated two-photon Raman processes in three-level systems. We compare four fundamental system configurations, one Λ -, one V-, and two ladder (Ξ -) configurations. These can be realized as subsystems of a single quantum dot or of quantum-dot molecules. For a new microscopic understanding of the Raman process, we analyze the Heisenberg equation of motion applying the cluster-expansion scheme. Within this formalism an exact and rigorous definition of a cavity-enhanced Raman photon via its corresponding Raman correlation is possible. This definition for example enables us to systematically investigate the on-demand potential of Raman-transition-based single-photon sources. The four system arrangements can be divided into two subclasses, Λ -type and V-type, which exhibit strongly different Raman-emission characteristics and Raman-emission probabilities. Moreover, our approach reveals whether the Raman path generates a single photon or just induces destructive quantum interference with other excitation paths. Based on our findings and as a first application, we gain a more detailed understanding of experimental data from the literature. Our analysis and results are also transferable to the case of atomic three-level-resonator systems and can be extended to more complicated multilevel schemes.

  2. Single Quantum Dot with Microlens and 3D-Printed Micro-objective as Integrated Bright Single-Photon Source.

    Science.gov (United States)

    Fischbach, Sarah; Schlehahn, Alexander; Thoma, Alexander; Srocka, Nicole; Gissibl, Timo; Ristok, Simon; Thiele, Simon; Kaganskiy, Arsenty; Strittmatter, André; Heindel, Tobias; Rodt, Sven; Herkommer, Alois; Giessen, Harald; Reitzenstein, Stephan

    2017-06-21

    Integrated single-photon sources with high photon-extraction efficiency are key building blocks for applications in the field of quantum communications. We report on a bright single-photon source realized by on-chip integration of a deterministic quantum dot microlens with a 3D-printed multilens micro-objective. The device concept benefits from a sophisticated combination of in situ 3D electron-beam lithography to realize the quantum dot microlens and 3D femtosecond direct laser writing for creation of the micro-objective. In this way, we obtain a high-quality quantum device with broadband photon-extraction efficiency of (40 ± 4)% and high suppression of multiphoton emission events with g (2) (τ = 0) < 0.02. Our results highlight the opportunities that arise from tailoring the optical properties of quantum emitters using integrated optics with high potential for the further development of plug-and-play fiber-coupled single-photon sources.

  3. A study of direct single photons and correlated particles in proton- proton collisions at square root s=624 GeV

    CERN Document Server

    Besch, H J; Blumenfeld, B; Camilleri, L L; Chapin, T J; Cool, R L; del Papa, C; Di Lella, L; Dimcovski, Zlatomir; Hollebeek, R J; Lederman, Leon Max; Levinthal, D A; Linnemann, J T; Newman, C B; Phinney, N; Pope, B G; Pordes, S H; Rothenberg, A F; Rusack, R W; Segar, A M; Smith, A M; Tannenbaum, M J; Vidal, R A; Wallace-Hadrill, J S; Yelton, J M; Young, K K

    1981-01-01

    An analysis is given of single photon production in pp interactions at 62 GeV, in an attempt to determine the proton's gluon distribution. Results are presented for the ratio f/sub gamma /= gamma /all and charge ratio. The former is enhanced, while the latter indicates an excess of high X/sub e/ positive particles in the single photon enhanced sample. Results suggest that the process qg to gamma q is significant in high p/sub T/ single photon production. (3 refs).

  4. 1.5 GHz single-photon detection at telecommunication wavelengths using sinusoidally gated InGaAs/InP avalanche photodiode.

    Science.gov (United States)

    Namekata, Naoto; Adachi, Shunsuke; Inoue, Shuichiro

    2009-04-13

    We report a telecom-band single-photon detector for gigahertz clocked quantum key distribution systems. The single-photon detector is based on a sinusoidally gated InGaAs/InP avalanche photodiode. The gate repetition frequency of the single-photon detector reached 1.5 GHz. A quantum efficiency of 10.8 % at 1550 nm was obtained with a dark count probability per gate of 6.3 x 10(-7) and an afterpulsing probability of 2.8 %. Moreover, the maximum detection rate of the detector is 20 MHz.

  5. EIGER: Next generation single photon counting detector for X-ray applications

    International Nuclear Information System (INIS)

    Dinapoli, Roberto; Bergamaschi, Anna; Henrich, Beat; Horisberger, Roland; Johnson, Ian; Mozzanica, Aldo; Schmid, Elmar; Schmitt, Bernd; Schreiber, Akos; Shi, Xintian; Theidel, Gerd

    2011-01-01

    EIGER is an advanced family of single photon counting hybrid pixel detectors, primarily aimed at diffraction experiments at synchrotrons. Optimization of maximal functionality and minimal pixel size (using a 0.25μm process and conserving the radiation tolerant design) has resulted in 75x75μm 2 pixels. Every pixel comprises a preamplifier, shaper, discriminator (with a 6 bit DAC for threshold trimming), a configurable 4/8/12 bit counter with double buffering, as well as readout, control and test circuitry. A novel feature of this chip is its double buffered counter, meaning a next frame can be acquired while the previous one is being readout. An array of 256x256 pixels fits on a ∼2x2cm 2 chip and a sensor of ∼8x4cm 2 will be equipped with eight readout chips to form a module containing 0.5 Mpixel. Several modules can then be tiled to form larger area detectors. Detectors up to 4x8 modules (16 Mpixel) are planned. To achieve frame rates of up to 24 kHz the readout architecture is highly parallel, and the chip readout happens in parallel on 32 readout lines with a 100 MHz Double Data Rate clock. Several chips and singles (i.e. a single chip bump-bonded to a single chip silicon sensor) were tested both with a lab X-ray source and at Swiss Light Source (SLS) beamlines. These tests demonstrate the full functionality of the chip and provide a first assessment of its performance. High resolution X-ray images and 'high speed movies' were produced, even without threshold trimming, at the target system frame rates (up to ∼24kHz in 4 bit mode). In parallel, dedicated hardware, firmware and software had to be developed to comply with the enormous data rate the chip is capable of delivering. Details of the chip design and tests will be given, as well as highlights of both test and final readout systems.

  6. Axial sidelobe reduction in single-photon 4Pi microscopy by Toraldo filters

    International Nuclear Information System (INIS)

    Martinex-Corral, M.; Pons, A.; Caballero, M.T.

    2002-01-01

    Full text: The 4Pi-confocal fluorescence microscope is a recently developed 3D imaging technique in which two opposing high-NA objectives are used for coherently illuminating and/or detecting the same point of the fluorescent sample. The interference process yields an intensity point spread function (PSF) with an extremely narrow axial core, but with very large axial sidelobes, which compromise the actual improvement in axial resolution. To overcome this problem we propose the use, in the illumination arm of the 4Pi-confocal microscope, of multiple-zones phase filters whose design is based on the Toraldo-design principle. Note that the Toraldo procedure allows to select at will the positions of the zeros of the PSF of an optical system. Then, what we propose here if to design a phase pupil filter such that the position of the first zero of the illumination axial PSF is close to the position of the maximum of the first axial sidelobe of the detection PSF. In the design procedure it is taken into account that: 1. The value of the parameter ε = λ exc /λ det which, in a single-photon fluorescent process, is the responsible for the different scales of the illumination and detection PSFs. 2. The Toraldo procedure was originally designed to control the position of zeros of the transverse PSF. In this case the procedure is adapted to the aim of controlling the position of zeros of the axial PSF. 3. Since 4Pi-confocal microscopes are only useful when built with high-NA objectives, the Toraldo principle is reformulated in terms of the nonparaxial diffraction theory. We show that by using Toraldo filters in the illumination part of a 4Pi-confocal microscope it is possible to obtain up to a 60% reduction of height of the axial sidelobe of the whole-system axial PSF. This fact permits to fully benefit the axial resolution from the strong narrowness of the central peak of the axial PSF, inherent to the 4Pi principle. Copyright (2002) Australian Society for Electron Microscopy

  7. Coherent properties of single quantum dot transitions and single photon emission

    Energy Technology Data Exchange (ETDEWEB)

    Ester, Patrick

    2008-04-23

    of the first laser pulse. The relative phase of the QDs exciton can be controlled externally via the bias voltage. This effect is the basis for the observation of RAMSEY-fringes, which are presented in this work. The coherent manipulation of the p-shell is the basis for a novel excitation scheme for single photon emission. In this work it is shown that the first excited state can be coherently manipulated, similar to the ground state. (orig.)

  8. Hole-Initiated-Avalanche, Linear-Mode, Single-Photon-Sensitive Avalanche Photodetector with Reduced Excess Noise and Low Dark Count Rate, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A radiation hard, single photon sensitive InGaAs avalanche photodiode (APD) receiver technology will be demonstrated useful for long range space based optical...

  9. On-Demand Single Photons with High Extraction Efficiency and Near-Unity Indistinguishability from a Resonantly Driven Quantum Dot in a Micropillar

    DEFF Research Database (Denmark)

    Ding, Xing; He, Yu; Duan, Z.-C.

    2016-01-01

    Scalable photonic quantum technologies require on-demand single-photon sources with simultaneously high levels of purity, indistinguishability, and efficiency. These key features, however, have only been demonstrated separately in previous experiments. Here, by s-shell pulsed resonant excitation...... of a Purcellenhanced quantum dot-micropillar system, we deterministically generate resonance fluorescence single photons which, at π pulse excitation, have an extraction efficiency of 66%, single-photon purity of 99.1%, and photon indistinguishability of 98.5%. Such a single-photon source for the first time combines...... the features of high efficiency and near-perfect levels of purity and indistinguishabilty, and thus opens the way to multiphoton experiments with semiconductor quantum dots....

  10. Single photon emission tomography in neurological studies: Instrumentation and clinical applications

    International Nuclear Information System (INIS)

    Nikkinen, P.

    1999-01-01

    One triple head and two single head gamma camera systems were used for single photon emission tomography (SPET) imaging of both patients and brain phantoms. Studies with an anatomical brain phantom were performed for evaluation of reconstruction and correction methods in brain perfusion SPET studies. The use of the triple head gamma camera system resulted in a significant increase in image contrast and resolution. This was mainly due to better imaging geometry and the use of a high resolution collimator. The conventional Chang attenuation correction was found suitable for the brain perfusion studies. In the brain perfusion studies region of interest (ROI) based semiquantitation methods were used. A ROI map based on anatomical areas was used in 70 elderly persons (age range 55-85 years) without neurological diseases and in patients suffering from encephalitis or having had a cardiac arrest. Semiquantitative reference values are presented. For the 14 patients with encephalitis the right-to-left side differences were calculated. Defect volume indexes were calculated for 64 patients with brain infarcts. For the 30 cardiac arrest patients the defect percentages and the anteroposterior ratios were used for semiquantitation. It is concluded that different semiquantitation methods are needed for the various patient groups. Age-related reference values will improve the interpretation of SPET data. For validation of the basal ganglia receptor studies measurements were performed using a cylindrical and an anatomical striatal phantom. In these measurements conventional and transmission imaging based non-uniform attenuation corrections were compared. A calibration curve was calculated for the determination of the specific receptor uptake ratio. In the phantom studies using the triple head camera the uptake ratio obtained from simultaneous transmission-emission protocol (STEP) acquisition and iterative reconstruction was closest to the true activity ratio. Conventional

  11. Final report on LDRD project : single-photon-sensitive imaging detector arrays at 1600 nm.

    Energy Technology Data Exchange (ETDEWEB)

    Childs, Kenton David; Serkland, Darwin Keith; Geib, Kent Martin; Hawkins, Samuel D.; Carroll, Malcolm S.; Klem, John Frederick; Sheng, Josephine Juin-Jye; Patel, Rupal K.; Bolles, Desta; Bauer, Tom M.; Koudelka, Robert

    2006-11-01

    uncertainty existed about the quantum efficiency at 1550 nm the necessary operating temperature. This project has resulted in several conclusions after fabrication and measurement of the proposed structures. We have successfully demonstrated the Ge/Si proof-of-concept in producing high analog gain in a silicon region while absorbing in a Ge region. This has included significant Ge processing infrastructure development at Sandia. However, sensitivity is limited at low temperatures due to high dark currents that we ascribe to tunneling. This leaves remaining uncertainty about whether this structure can achieve the desired performance with further development. GM detection in InGaAs/InAlAs, Ge/Si, Si and pure Ge devices fabricated at Sandia was shown to overcome gain noise challenges, which represents critical learning that will enable Sandia to respond to future single photon detection needs. However, challenges to the operation of these devices in GM remain. The InAlAs multiplication region was not found to be significantly superior to current InP regions for GM, however, improved multiplication region design of InGaAs/InP APDs has been highlighted. For Ge GM detectors it still remains unclear whether an optimal trade-off of parameters can achieve the necessary sensitivity at 1550 nm. To further examine these remaining questions, as well as other application spaces for these technologies, funding for an Intelligence Community post-doc was awarded this year.

  12. Particles Produced in Association with High Transverse Momentum Single Photons and $\\pi^0$s in Hadronic Collision

    Energy Technology Data Exchange (ETDEWEB)

    Sinanidis, Alexandros Pericles [Northeastern U.

    1989-01-01

    The charged and neutral particles produced in association with high transverse momentum ($Pr_{\\tau}$ > 5.0 GeV /c) photons ($\\gamma$) and neutral pions ($\\pi^0$) in p(Cu+Be) and $\\pi^-$(cu+Be) collisions at vs = 31.5 GeV are studied in this thesis. It was observed that 1) The relative rapidity of the two highest Pr recoiling particles in the events have a jet - like structure. 2) The relative rapidity of the single $\\gamma$ (or $\\pi^0$ ) and the highest $P_{\\tau}$ charged particle accompanying the single $\\gamma$ (or $\\pi^0$ ) show that the high $P_{\\tau} \\pi^0$ events have a jet - like structure in the trigger hemisphere whereas the high $P_{\\tau}$ single $\\gamma$ events do not. 3) The angular distributions of the particles produced in the reactions show that high $P_{\\tau} \\pi^0$s are accompanied by other particles, whereas high $P_{\\tau}$ single photons are relatively isolated. 4) The fragmentation distributions of the recoiling particles from the high $P_{\\tau}$ single photons and $\\pi^0$s are consistent with the measurements of other experiments. 5) The recoiling particles are consistent with the fragmentation of either a quark or a gluon according to the QCD (Quantum Chromodynamics). In summary, particles produced in association with high transverse momentum single photons and $\\pi^0$s in hadronic collisions have been measured and their properties are in good agreement with the predictions of the parton model and those of QCD

  13. Coherent Anti-Stokes and Coherent Stokes in Raman Scattering by Superconducting Nanowire Single-Photon Detector for Temperature Measurement

    Directory of Open Access Journals (Sweden)

    Annepu Venkata Naga Vamsi

    2016-01-01

    Full Text Available We have reported the measurement of temperature by using coherent anti-Stroke and coherent Stroke Raman scattering using superconducting nano wire single-photon detector. The measured temperatures by both methods (Coherent Anti-Raman scattering & Coherent Stroke Raman scattering and TC 340 are in good accuracy of ± 5 K temperature range. The length of the pipe line under test can be increased by increasing the power of the pump laser. This methodology can be widely used to measure temperatures at instantaneous positions in test pipe line or the entire temperature of the pipe line under test.

  14. Effect of expression of P-glycoprotein on technetium-99m methoxyisobutylisonitrile single photon emission computed tomography of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Yasushi; Matsumura, Akira; Nose, Tadao [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-08-01

    The expression of P-glycoprotein was investigated imunohistochemically in 26 brain tumor tissues and compared with the findings of technetium-99m methoxyisobutylisonitrile single photon emission computed tomography ({sup 99m}Tc-MIBI SPECT) to clarify the effect of P-glycoprotein on the diagnostic accuracy. P-glycoprotein labeling index of both tumor cells and vascular endothelial cells showed no clear relationship with the findings of {sup 99m}Tc-MIBI SPECT imaging. Expression of P-glycoprotein has no effect on the diagnostic accuracy of {sup 99m}Tc-MIBI SPECT. (author)

  15. Single photon emission tomography using sup(99m)Tc-HM-PAO in the investigation of dementia

    International Nuclear Information System (INIS)

    Neary, D.; Snowden, J.S.; Shields, R.A.; Burjan, A.W.I.; Northen, B.; Macdermott, N.; Prescott, M.C.; Testa, H.J.

    1987-01-01

    Single photon emission tomographic imaging of the brain using sup(99m)Tc HM-PAO was carried out in patients with a clinical diagnosis of Alzheimer's disease, non-Alzheimer frontal-lobe dementia, and progressive supranuclear palsy. Independent assessment of reductions in uptake revealed posterior hemisphere abnormalities in the majority of the Alzheimer group, and selective anterior hemisphere abnormalities in both other groups. The findings were consistent with observed patterns of mental impairment. The imaging technique has potential value in the differential diagnosis of primary cerebral atrophy. (author)

  16. Clinical applications of single photon emission tomography in neuromedicine. Part 1. Neuro-oncology, epilepsy, movement disorders, cerebrovascular disease

    International Nuclear Information System (INIS)

    Bartenstein, P.; Gruenwald, F.; Kuwert, T.; Tatsch, K.; Sabri, O.; Benkert, O.; Fahlbusch, R.; Gruender, G.; Herzholz, K.; Weiller, C.

    2000-01-01

    Single photon emission tomography is, because of its availability and the relatively low costs, the functional imaging modality currently most widely used for clinical applications in the brain. Beside the application of radiopharmaceuticals for the assessment of regional cerebral blood flow there is an increasing clinical use of more selective SPECT-radiopharmaceuticals, like amino acid analogs or receptor ligands. This article gives in its first part a critical review of the clinical applications of SPECT in neuro-oncology, epilepsy, basal ganglia disorders and cerebrovascular disease. (orig.) [de

  17. Time-over-threshold readout to enhance the high flux capabilities of single-photon-counting detectors.

    Science.gov (United States)

    Bergamaschi, Anna; Dinapoli, Roberto; Greiffenberg, Dominic; Henrich, Beat; Johnson, Ian; Mozzanica, Aldo; Radicci, Valeria; Schmitt, Bernd; Shi, Xintian; Stoppani, Laura

    2011-11-01

    The MYTHEN single-photon-counting (SPC) detector has been characterized using the time-over-threshold (ToT) readout method, i.e. measuring the time that the signal produced by the detected X-rays remains above the comparator threshold. In the following it is shown that the ToT readout preserves the sensitivity, dynamic range and capability of background suppression of the SPC mode, while enhancing the count-rate capability, which is the main limitation of state-of-the-art SPC systems.

  18. First observation of two-electron one-photon transitions in single-photon K-shell double ionization.

    Science.gov (United States)

    Hoszowska, J; Dousse, J-Cl; Szlachetko, J; Kayser, Y; Cao, W; Jagodziński, P; Kavčič, M; Nowak, S H

    2011-07-29

    Experimental evidence for the correlated two-electron one-photon transitions (1s(-2)→2s(-1)2p(-1)) following single-photon K-shell double ionization is reported. The double K-shell vacancy states in solid Mg, Al, and Si were produced by means of monochromatized synchrotron radiation, and the two-electron one-photon radiative transitions were observed by using a wavelength dispersive spectrometer. The two-electron one-photon transition energies and the branching ratios of the radiative one-electron to two-electron transitions were determined and compared to available perturbation theory predictions and configuration interaction calculations.

  19. Cavity-enhanced radiative emission rate in a single-photon-emitting diode operating at 0.5 GHz

    International Nuclear Information System (INIS)

    Ellis, David J P; Bennett, Anthony J; Dewhurst, Samuel J; Shields, Andrew J; Nicoll, Christine A; Ritchie, David A

    2008-01-01

    We report the observation of a Purcell enhancement in the radiative decay rate of a single quantum dot, embedded in a microcavity light-emitting-diode structure. Lateral confinement of the optical mode was achieved using an annulus of low-refractive-index aluminium oxide, formed by wet oxidation. The same layer acts as a current aperture, reducing the active area of the device without impeding the electrical properties of the p-i-n diode. This allowed single photon electroluminescence to be demonstrated at repetition rates up to 0.5 GHz

  20. Single photon emission and quantum ring-cavity coupling in InAs/GaAs quantum rings

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo, E; Nowak, A K; Sanvitto, D; Meulen, H P van der; Calleja, J M [Departamento de Fisica de Materiales, Universidad Autonoma de Madrid, E-28049 Madrid (Spain); MartInez, L J; Prieto, I; Alija, A R; Granados, D; Taboada, A G; GarcIa, J M; Postigo, P A [Instituto de Microelectronica de Madrid, Centro Nacional de MicrotecnologIa, CSIC, Isaac Newton 8, PTM Tres Cantos, E-28760 Madrid (Spain); Sarkar, D, E-mail: eva.gallardo@uam.e [Department of Physics and Astronomy, University of Sheffield, S3 7RH (United Kingdom)

    2010-02-01

    Different InAs/GaAs quantum rings embedded in a photonic crystal microcavity are studied by quantum correlation measurements. Single photon emission, with g{sup (2)}(0) values around 0.3, is demonstrated for a quantum ring not coupled to the microcavity. Characteristic rise-times are found to be longer for excitons than for biexcitons, resulting in the time asymmetry of the exciton-biexciton cross-correlation. No antibunching is observed in another quantum ring weakly coupled to the microcavity.