WorldWideScience

Sample records for investigaciones electricas fluidized

  1. The Instituto de Investigaciones Electricas fluidized bed combustor; El combustor de lecho fluidizado del Instituto de Investigaciones Electricas

    Energy Technology Data Exchange (ETDEWEB)

    Milan Foressi, Julio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1991-12-31

    After synthesizing the most important aspects of the combustion technology in fluidized bed, the experimental combustor developed at the Instituto de Investigaciones Electricas (IIE) is described, as well as the test results of the experiences carried out with coal from Rio Escondido, Coahuila. [Espanol] Tras sintetizar los aspectos mas importantes de la tecnologia de combustion en lecho fluidizado, se describe el combustor experimental desarrollado en el Instituto de Investigaciones Electricas (IIE), asi como los resultados de las experiencias realizadas con carbon proveniente de Rio Escondido, Coahuila.

  2. Qualitative aspects in the projects that are developed in the Instituto de Investigaciones Electricas; Aspectos cualitativos en los proyectos que se desarrollan en el Instituto de Investigaciones Electricas

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Neblina, Joaquin [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    1999-07-01

    The globalization of markets has generated more options of purchase of all type of goods and services, these options have generated opportunities and threats for all the companies and have looked for the satisfaction of the client as a strategy to remain or incursion into the global market. The Instituto de Investigaciones Electricas (IIE) is not the exception and therefore it looks for the identification of the qualitative aspects and to systematize its application in the projects that executes by means of the implantation of a system of quality assurance based on the series of ISO 9000 Standards. Some examples are described to identify the qualitative aspects of the projects that are developed in the Institute. [Spanish] La globalizacion de los mercados ha generado mas opciones de compra de todo tipo de bienes y servicios, dichas opciones han generado oportunidades y amenazas para todas las empresas y se ha buscado satisfacer al cliente como estrategia para permanecer o incursionar en el mercado global. El Instituto de Investigaciones Electricas (IIE) no es la excepcion y por lo tanto busca identificar los aspectos cualitativos y sistematizar su aplicacion en los proyectos que realiza mediante la implantacion de un sistema de aseguramiento de la calidad basado en la serie de normas ISO 9000. Se describen algunos ejemplos para identificar los aspectos cualitativos de los proyectos que se desarrollan en el instituto.

  3. Work Report 1994-1995 Instituto de Investigaciones Electricas (Electrical Research Institute)

    International Nuclear Information System (INIS)

    Instituto de Investigaciones Electricas.

    1995-01-01

    The Instituto de Investigaciones Electricas (Electrical Research Institute) collaborates with the Comision Federal de Electricidad (Electricity Federal Commission) and with the public and private entities of the electric sector in the solution of scientific and technological problems. The activity of the Institute follows the lineaments of the Secretaria de Energia (Energy Secretariat) and is inside the frame of the programs of national modernization. This two-year report presents in seven sections the activities of the Institute; the sections are: 1. Importance of the IIE in the economic context of the Governmental sector. 2. Orientations of sectorial structural policy and main operation results. 3. Structural change, 1994-1995. 4. Research and Development, advances and results. 5. Budget and financial situation. 6. Statistical Annex. 7. Glossary

  4. Anaerobic/aerobic treatment for the waste water from the Instituto de Investigaciones Electricas installations; Tratamiento anaerobio-aerobio de las aguas residuales de las instalaciones del IIE

    Energy Technology Data Exchange (ETDEWEB)

    Arvizu Fernandez, Jose Luis [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    The waste water treatment plant of the Instituto de Investigaciones Electricas (IIE) is analyzed. This plant originally was a plant of the activated sludge type (aerobic development), process that consumes large amounts of energy and that produces residual sludge 5 or 6 times greater than the anaerobic processes. The methodology and the techniques utilized were base in the analysis of the existing plant introducing an anaerobic treatment and performing laboratory experimentation. The plant design parameters considered are described. The results show the benefits of treating by anaerobic means the waste waters since depuration are obtained on the order of 75%, as well as the reduction of resulting residual sludge and in energy consumption. A reduction of 60% to 70% can be attained if a combination of anaerobic and aerobic processes is utilized [Espanol] Se analiza la planta de tratamiento de aguas residuales del Instituto de Investigaciones Electricas (IIE). Esta planta era originalmente una planta de lodos activados (desarrollo aerobio), proceso que consume mucha energia y genera lodos residuales de 5 a 6 veces mas que los procesos anaerobios. La metodologia y las tecnicas utilizadas se basaron en el analisis de la planta de tratamiento existente en el IIE; en la caracterizacion residual del IIE; en la modificacion de la planta de tratamiento introduciendo un tratamiento anaerobio y efectuando experimentacion en laboratorio. Se describen los parametros de diseno de la planta considerados. Los resultados muestran los beneficios de tratar por medios anaerobios las aguas residuales ya que se obtienen depuraciones del orden del 75%, asi como la reduccion de lodos residuales resultantes y el consumo de energia, pueden reducirse de un 60% a un 70% si se utiliza la combinacion de los procesos anaerobios y aerobios

  5. Research activities in the use of energy; Actividades de investigacion en el uso de la energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Covarrubias Ramos, Rogelio; Garcia Juarez, Francisco [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    The use of energy is intimately related to the development and is found in the human activities of all types, consequently we could say that to a greater usage it must correspond a greater benefit. This paper carries on a comparative analysis of the Mexico`s energy efficiency versus industrialized countries; this analysis shows that while Mexico indicates a growing tendency, in the industrialized countries the tendency is to the drop, unmistakable sign of a better usage of the energy sources. It also makes evident that promoting the energy efficiency in Mexico will stimulate and regulate the energy conservation at National level, in the same way it is mentioned that an appropriate energy demand Management for the users as well as for the service providers, will diminish the peak demand, the adequate application of the electric rates at the actual conditions and the energy saving and the strategic load growth [Espanol] El uso de la energia esta intimamente relacionado con el desarrollo y se encuentra en las actividades humanas de todo tipo, de tal suerte que podriamos decir que a mayor uso debe corresponder un mayor beneficio. En este documento se realiza un analisis comparativo de la eficiencia energetica en Mexico contra paises industrializados; este analisis muestra que mientras Mexico indica una tendencia creciente, en los paises industrializados la tendencia es a la baja, signo inequivoco de un mejor uso de los energeticos, tambien hace ver que la promocion de la eficiencia energetica en Mexico estimulara y regulara el ahorro de energia a nivel nacional, de igual manera se menciona que una buena administracion de la demanda energetica tanto por los usuarios como los que prestan el servicio, reducira la demanda pico, la adecuacion de las tarifas electricas a las condiciones reales y el ahorro de los energeticos y el crecimiento estrategico de la carga

  6. Experimental study on fuel oil combustion in circulating fluidized bed; Estudio experimental sobre la combustion de combustoleo en lecho fluidizado circulante

    Energy Technology Data Exchange (ETDEWEB)

    Diaz Rangel, Ricardo [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    The Instituto de Investigaciones Electricas (IIE) developed a circulating fluidized bed combustor of 0.5 thermal MW unique in its type in Latin America. The Bachelor`s thesis entitled ``Experimental Study on Fuel Oil Combustion in Circulating Fluidized Bed`` was performed operating this combustor with the purpose of determining the feasibility of burning heavy fuel oil in a stable and sustained form, as well as the effect of the addition of calcium carbonate to the combustor. The results of the experimental trials showed heavy fuel oil can be burned in a circulating fluidized bed, with low sulfur dioxide emissions. During the conduction of the experiments a sulfur retention of 43% was achieved with a Ca/S relationship of 4.5. [Espanol] El Instituto de Investigaciones Electricas (IIE) desarrollo un combustor de lecho fluidizado circulante de 0.5 MW termicos de potencia, unico en su tipo en Latinoamerica. La tesis de licenciatura titulada Estudio Experimental sobre la Combustion de Combustoleo en Lecho Fluidizado Circulante se realizo operando dicho combustor, con el proposito de determinar la factibilidad de quemar combustoleo pesado en forma estable y autosostenida, asi como la influencia que tiene la adicion de carbonato de calcio al lecho. Los resultados de los ensayos experimentales mostraron que se puede quemar combustoleo pesado en un lecho fluidizado circulante, con bajas emisiones de bioxido de azufre. Durante la experimentacion se logro una retencion de azufre del 43%, con una relacion Ca/S de 4.5.

  7. Calculation of electromagnetic fields in electric machines by means of the finite element. Computational aspects; Calculo de campos electromagneticos en maquinas electricas mediante elemento finito. Aspectos computacionales

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, Mario; De la Torre, Octavio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1989-12-31

    In this article are described the computational characteristics of the Package CALIIE 2D of the Instituto de Investigaciones Electricas (IIE), for the calculation of bi-dimensional electromagnetic fields. The computational implementation of the package is based in the electromagnetic and numerical statements formerly published in this series. [Espanol] En este articulo se describen las caracteristicas computacionales del paquete CALIIE 2D del Instituto de Investigaciones Electricas (IIE), para calcular campos electromagneticos bidimensionales. La implantacion computacional del paquete se basa en los planteamientos electromagneticos y numericos antes publicados en esta serie.

  8. Calculation of electromagnetic field in electric machines through the finite element: Electromagnetic modeling; Calculo de campos electromagneticos en maquinas electricas mediante elemento finito: Modelacion electromagnetica

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, Mario F. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    In this article are presented the general characteristics of the electromagnetic phenomena that can be described by means of the software CALIIE-2D of the Instituto de Investigaciones Electricas (IIE) derived from a modeling based in the magnetic and electric potentials, always using the MKS rationalized units system. Closed regions are considered with axial or moving symmetry to incorporate the bi-dimensional behavior of the electromagnetic fields. The possibility of means with movement is also included. [Espanol] En este articulo se presentan las caracteristicas generales de los fenomenos electromagneticos que pueden describirse mediante el programa de computo CALIIE-2D, del Instituto de Investigaciones Electricas (IIE), que provienen de una modelacion basada en los potenciales magnetico y electrico, en esta se utiliza sistema MKS racionalizado de unidades. Se consideran regiones cerradas con simetria axial o traslacional para incorporar el comportamiento bidimensional de los campos electromagneticos, se incluye tambien la posibilidad de medios con movimiento.

  9. Fluidization quality analyzer for fluidized beds

    Science.gov (United States)

    Daw, C.S.; Hawk, J.A.

    1995-07-25

    A control loop and fluidization quality analyzer for a fluidized bed utilizes time varying pressure drop measurements. A fast-response pressure transducer measures the overall bed pressure drop, or over some segment of the bed, and the pressure drop signal is processed to produce an output voltage which changes with the degree of fluidization turbulence. 9 figs.

  10. Methodology for the prediction and solution of the harmonic distortion in the distribution power lines; Metodologia para la prediccion y solucion de la distorsion armonica en las redes electricas de distribucion

    Energy Technology Data Exchange (ETDEWEB)

    Velazquez Sanchez, Raul [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1994-03-01

    The harmonic distortion in the distribution electric systems, caused by the increment in the utilization of power electronics, presents a growing problem for the power supply enterprises, as well as for their users. The distortion of the voltage wave shape in the distribution electric systems can produce additional heating in transformers, damage in motors, faults in capacitor banks, frequent fuse capacitors banks operation and inadequate operation of controllers and protecting schemes. This paper presents a general overview on the harmonics problem in distribution systems. The sources of harmonic currents, their effects in the electric system and the methodology implemented in the Instituto de Investigaciones Electricas (IIE) for their detection, measurement and control, are described. [Espanol] La distorsion armonica en los sistemas electricos de distribucion, ocasionada por el incremento en la utilizacion de la electronica de potencia, presenta un problema creciente tanto para las empresas suministradoras de energia electrica como para sus usuarios. La distorsion de la forma de onda del voltaje en los sistemas de distribucion de energia electrica puede producir calentamiento adicional en transformadores, dano en motores, fallas en bancos de capacitores, operacion frecuente de fusibles de bancos de capacitores y operacion inadecuada de controladores y esquemas de proteccion. En este trabajo se presenta un panorama general sobre el problema de armonicas en redes de distribucion. Se describen las fuentes de corrientes armonicas, sus efectos en el sistema electrico y la metodologia implantada en el Instituto de Investigaciones Electricas (IIE) para detectarlas, medirlas y controlarlas.

  11. Seismic damage in the electrical substations of the Colima state; Dano sismico en las subestaciones electricas del estado de Colima

    Energy Technology Data Exchange (ETDEWEB)

    Mena H, Ulises; Lopez L, Alberto; Guerrero F, Vicente A. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2004-07-01

    On the 21 of January of 2003, at 20:06:36 hrs (Mexico center time) an earthquake occurred at the Pacific coast with a magnitude of 7.6 degrees in the Richter scale, whose epicenter was located near the state of Colima and it was felt in a large extent of the Mexican Republic. The earthquake caused numerous material damages in the structures (houses, churches, offices, etc) and vital lines, mainly in the infrastructure of the electrical sector of the region, leaving without electrical energy a large part of the nearby populations and some colonies of distant zones such as in Mexico City. The cause of the interruption of the electrical energy was due to the collapse of some of the equipment of 400 and 230 KV of the electrical transmission substations, among which are Manzanillo II and Colima II. With the experience acquired in the earthquake of October 9, 1995 in Manzanillo, in which also the facilities and equipment of the electrical substations were affected considerably, and as a part of the infrastructure project on the analysis of seismic risk of vital lines that is being developed at this moment at the Instituto de Investigaciones Electricas (IIE), it was decided to inspect the electrical substations of the zone, where the greater damages in the facilities and equipment were reported, to analyze and to determine the main causes of their failure. [Spanish] El 21 de enero de 2003, a las 20:06:36 hrs (hora del centro de Mexico) ocurrio un sismo en la costa del Pacifico con una magnitud de 7.6 grados en escala Richter, cuyo epicentro se localizo cerca del estado de Colima y se percibio en gran parte de la republica mexicana. El sismo causo cuantiosos danos materiales en las estructuras (viviendas, iglesias, oficinas, etc) y lineas vitales, principalmente en la infraestructura del sector electrico de la region, dejando sin energia electrica a gran parte de las poblaciones cercanas y algunas colonias de zonas lejanas como es la ciudad de Mexico. La causa del corte de

  12. On partial fluidization in rotating fluidized beds

    International Nuclear Information System (INIS)

    Kao, J.; Pfeffer, R.; Tardos, G.I.

    1987-01-01

    In a rotating fluidized bed, unlike in a conventional fluidized bed, the granules are fluidized layer by layer from the (inner) free surface outward at increasing radius as the gas velocity is increased. This is a very significant and interesting phenomenon and is extremely important in the design of these fluidized beds. The phenomenon was first suggested in a theoretical analysis and recently verified experimentally in the authors' laboratory. However, in the first paper, the equations presented are too cumbersome and the influence of bed thickness is not clearly stated. In this note the authors present simplified equations, based on that paper, for the pressure drop and the minimum fluidizing velocities in a rotating fluidized bed. Experimental data are also shown and compared with the theoretical model, and the effect of bed thickness is shown. Furthermore, an explanation for the observation of a maximum in the pressure drop vs. velocity curve instead of the plateau derived by Chen is proposed

  13. The electric energy and the environment in Mexico. Volume 3; Energia electrica y medio ambiente en Mexico. Volumen 3

    Energy Technology Data Exchange (ETDEWEB)

    Quintanilla Martinez, Juan [eds.] [Universidad Nacional Autonoma de Mexico, Mexico, D. F. (Mexico)

    1997-12-31

    This document is the third one of three volumes of the 1. Seminar on the Current Conditions and Perspectives of the Electric Sector in Mexico, organized by the Programa Universitario de Energia and the Instituto de Investigaciones Economicas (University Program of Energy and the Institute of Economic Research), both of them agencies of the Universidad Autonoma de Mexico (UNAM). The titles of the three volumes are the following: Volume 1.- The opening of the Mexican Electric Sector to foreign investment. Volume 2.- Concrete innovation and technological learning experiences at the Luz y Fuerza del Centro enterprise. Volume 3.- The Electric Energy and the Environment in Mexico. This third volume covers the following subjects: Hydroelectricity, land use and water managing; the electric generation in Mexico and its environmental impact, the nuclear electricity and the handling of radioactive materials; the exposure to electromagnetic fields and its association with children`s leukemia; the energy in Mexico and the sustainable development; potential of electricity generation in large scale with wind power in Mexico; towards a scheme of distributed electric power generation with non-conventional energies and renewable energy sources in Mexico in the 21Century. These documents were elaborated by specialists of the electric sector, from the sector itself as well as from private and public academic entities [Espanol] Este documento constituye el tercero de tres volumenes del Primer Seminario sobre Situacion y Perspectivas del Sector Electrico en Mexico, organizado por el Programa Universitario de Energia y el Instituto de Investigaciones Economicas, ambas dependencias de la Universidad Nacional Autonoma de Mexico (UNAM). Los titulos de los tres volumenes son los siguientes: volumen 1: La apertura externa del sector electrico mexicano, volumen 2: Experiencias concretas de innovacion y aprendizaje tecnologico en la empresa Luz y Fuerza del Centro, volumen 3: Energia electrica

  14. The rebranding of Electrica Soluziona SA - a case study

    OpenAIRE

    Monica GOMOESCU

    2016-01-01

    This article intends to present the design and implementation stages of a rebranding campaign that took place in the Electrica Soluziona SA company. The rebranding targets a company that provides consultancy services and software solutions and that underwent a change of its main shareholders structure, as it was taken over by Indra Group. After being taken over by Indra, Electrica Soluziona has considerably enlarged its product portfolio and the market segments targeted. Thus, ...

  15. Supervisory control for hybrid systems of electrical generation based on fuzzy logic; Control supervisorio para sistemas hibridos de generacion electrica basado en logica difusa

    Energy Technology Data Exchange (ETDEWEB)

    Lagunas M, Javier; Ortega S, Cesar [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Caratozzolo M, Patricia [Instituto Tecnologico de Estudios Superiores de Monterrey, campus Cd. de Mexico (Mexico)

    2005-07-01

    The development and integration of hybrid systems of electrical generation (SHGE) of small capacity: The intention of these developments is its implementation in isolated or far away communities from conventional electric networks, that contribute in the own productive processes of these towns. As part of these work a system of control for their hybrid system wind-photovoltaic- internal combustion machine was developed that operates nowadays in a system installed in Pachuca, Hidalgo, Mexico. However, in the two past years, the GENC has worked, altogether with the Management of Control and Instrumentation of the Instituto de Investigaciones Electricas (IIE) and the Centro Nacional de Investigacion y Desarrollo Tecnologico (CENIDET) (National Center of Research and Technological Development), to incorporate an intelligent control technique in the regulation of the hybrid systems of wind-photovoltaic-machine of internal combustion type. Lemos de Pereira rises that the main problems of the present technology of the SHGE are related to the control and supervision of the power systems. The system that is in charge of the actions of load control and dispatch is denominated supervisory control. This controller supervises the operation of all the components, regulates the entry or exiting of operation of the generation systems, as well as the loads. [Spanish] El desarrollo e integracion de sistemas hibridos de generacion electrica (SHGE) de pequena capacidad. El proposito de estos desarrollos es su implementacion en comunidades aisladas o alejadas de la red electrica convencional, las cuales contribuyan en los procesos productivos propios de estos poblados. Como parte de dichos trabajos se desarrollo un sistema de control para su sistema hibrido eolico-fotovoltaico-maquina de combustion interna que opera actualmente en un sistema instalado en Pachuca, Hidalgo, Mexico. Ahora bien, en los dos ultimos anos, la GENC ha trabajado, en conjunto con la Gerencia de Control e

  16. Research, development and technological innovation of wind turbine control systems; Investigacion, desarrollo e innovacion tecnologica de sistemas de control de aerogeneradores

    Energy Technology Data Exchange (ETDEWEB)

    Garduno Ramirez, Raul; Rodriguez Martinez, Arnulfo Antelmo; Sanchez Parra, Marino; Martinez Morales, Miguel Angel; Hernandez Cuellar, Maria Aurora; Alcaide Godinez, Indira Xochiquetzal; Re Lopez, Victor Genaro; Hernandez Gonzalez, Roberto [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2012-07-01

    Control systems constitute the brain and the nervous system of modern machines, such as wind turbine generators (TGE by its acronym in Spanish). TGEs can work efficiently, safely and almost autonomously, thanks to the control systems with which they are equipped. Conversely, any malfunctioning of the control system may cause failure or damage of a component, a subsystem or even destruction of the TGE itself. This paper introduces some basic facts about generation of electric power from wind energy in the world and Mexico, wind turbogenerators and their most relevant technologies, TGE control systems, and R and TD+I about TGE control systems performed at the Instituto de Investigaciones Electricas. [Spanish] Los sistemas de control constituyen el cerebro y el sistema nervioso de las maquinas modernas, como aerogeneradores (AG). Los AG pueden trabajar eficiente, segura y casi autonomamente, gracias a los sistemas de control con los que estan equipados. De manera inversa, cualquier mal funcionamiento del sistema de control puede provocar falla o dano de un componente, subsistema o incluso la destruccion del propio AG. Este documento introduce algunos hechos basicos en torno a la generacion de energia electrica a partir de energia eolica en el mundo y Mexico, los aerogeneradores y sus tecnologias mas importantes, sistemas de control de AG e I+DT alrededor de los sistemas de control de AG realizados en el Instituto de Investigaciones Electricas.

  17. The rebranding of Electrica Soluziona SA - a case study

    Directory of Open Access Journals (Sweden)

    Monica GOMOESCU

    2016-07-01

    Full Text Available This article intends to present the design and implementation stages of a rebranding campaign that took place in the Electrica Soluziona SA company. The rebranding targets a company that provides consultancy services and software solutions and that underwent a change of its main shareholders structure, as it was taken over by Indra Group. After being taken over by Indra, Electrica Soluziona has considerably enlarged its product portfolio and the market segments targeted. Thus, it was mandatory to define a complex rebranding campaign. The rebranding process was not determined only by the broadening of activity, but also by the change of visual identity elements, along with the desire of repositioning.

  18. Annual statistical report UNESA 1994; Memoria Estadistica Electrica UNESA 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    UNESA (Unidad Electrica, S.A.) comprises 14 Spanish electric utilities. This review summarises activities and achievements during the year. It presents statistics for the years 1988 to 1994 on the national economy and the finances of the electricity sector; operating capacity and transmission and distribution lines; and electricity production and consumption. Financial statements of the electricity industry as of 31 December 1994 are presented. The report is also available in English.

  19. UNESA annual statistical report 1995; Memoria estadistica electrica UNESA 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    UNESA (Unidad Electrica, S.A.) comprises 14 Spanish electric utilities. This review summarises activities and achievements during the year. It presents statistics for the years 1988 to 1995 on the national economy and the finances of the electricity sector; operating capacity and transmission and distribution lines; and electricity production, demand and consumption. Financial statements of the electricity industry as of 31 December 1995 are presented.

  20. Calculation of electromagnetic fields in electric machines by means of the finite element. Algorithms for the solution of problems with known total densities. Pt. 2; Calculo de campos electromagneticos en maquinas electricas mediante elemento finito. Algoritmos para la solucion de problemas con densidades totales conocidas. Pt. 2

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, Mauricio F. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    This article is based in the electromagnetic modeling presented in the first part. Here are only considered the magnetic systems or electric systems in closed regions with moving or axial symmetry, whose total current density or total electric load density is known. The algorithms that have been implanted in the software CLIIE-2D of the Instituto de Investigaciones Electricas (IIE) are developed in order to obtain numerical solutions for these problems. The basic systems of algebraic equations are obtained by means of the application of the Galerkin method in the discreteness of the finite element with first order triangular elements. [Espanol] Este articulo se basa en la modelacion electromagnetica presentada en la primera parte. Aqui solo se consideran sistemas magneticos o sistemas electricos en regiones cerradas con simetria translacional o axial, cuya densidad de corriente total o densidad de carga electrica total es conocida. Se desarrollan los algoritmos que se han implantado en el programa de computo CLIIE-2D, del Instituto de Investigaciones Electricas (IIE) con el fin de obtener soluciones numericas para estos problemas. Los sistemas basicos de ecuaciones algebraicas se obtienen mediante la aplicacion del metodo de Galerkin en la discretizacion de elemento finito con elementos triangulares de primer orden.

  1. Fluidization of spherocylindrical particles

    Directory of Open Access Journals (Sweden)

    Mahajan Vinay V.

    2017-01-01

    Full Text Available Multiphase (gas-solid flows are encountered in numerous industrial applications such as pharmaceutical, food, agricultural processing and energy generation. A coupled computational fluid dynamics (CFD and discrete element method (DEM approach is a popular way to study such flows at a particle scale. However, most of these studies deal with spherical particles while in reality, the particles are rarely spherical. The particle shape can have significant effect on hydrodynamics in a fluidized bed. Moreover, most studies in literature use inaccurate drag laws because accurate laws are not readily available. The drag force acting on a non-spherical particle can vary considerably with particle shape, orientation with the flow, Reynolds number and packing fraction. In this work, the CFD-DEM approach is extended to model a laboratory scale fluidized bed of spherocylinder (rod-like particles. These rod-like particles can be classified as Geldart D particles and have an aspect ratio of 4. Experiments are performed to study the particle flow behavior in a quasi-2D fluidized bed. Numerically obtained results for pressure drop and bed height are compared with experiments. The capability of CFD-DEM approach to efficiently describe the global bed dynamics for fluidized bed of rod-like particles is demonstrated.

  2. Fluidization of spherocylindrical particles

    Science.gov (United States)

    Mahajan, Vinay V.; Nijssen, Tim M. J.; Fitzgerald, Barry W.; Hofman, Jeroen; Kuipers, Hans; Padding, Johan T.

    2017-06-01

    Multiphase (gas-solid) flows are encountered in numerous industrial applications such as pharmaceutical, food, agricultural processing and energy generation. A coupled computational fluid dynamics (CFD) and discrete element method (DEM) approach is a popular way to study such flows at a particle scale. However, most of these studies deal with spherical particles while in reality, the particles are rarely spherical. The particle shape can have significant effect on hydrodynamics in a fluidized bed. Moreover, most studies in literature use inaccurate drag laws because accurate laws are not readily available. The drag force acting on a non-spherical particle can vary considerably with particle shape, orientation with the flow, Reynolds number and packing fraction. In this work, the CFD-DEM approach is extended to model a laboratory scale fluidized bed of spherocylinder (rod-like) particles. These rod-like particles can be classified as Geldart D particles and have an aspect ratio of 4. Experiments are performed to study the particle flow behavior in a quasi-2D fluidized bed. Numerically obtained results for pressure drop and bed height are compared with experiments. The capability of CFD-DEM approach to efficiently describe the global bed dynamics for fluidized bed of rod-like particles is demonstrated.

  3. Fluidized bed incinerator development

    International Nuclear Information System (INIS)

    Ziegler, D.L.; Johnson, A.J.

    1976-01-01

    A fluidized bed incinerator is being developed for burning rad contaminated solid and liquid waste materials. In situ neutralization of acid gases by the bed material, catalytic afterburning, and gas filtration are used to produce a clean flue gas without the use of aqueous scrubbing

  4. System for the design of electrical distribution substations; Sistema para el diseno de subestaciones electricas de distribucion

    Energy Technology Data Exchange (ETDEWEB)

    Zayas Perez, Benjamin Eddie; Islas Perez, Eduardo; Bahena Rada, Jessica Liliana; Romero Lima, Jesus [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Sierra Rodriguez, Benjamin; Moreno Diaz, Humberto [Comision Federal de Electricidad (Mexico)

    2011-07-01

    llevan a cabo en las Divisiones de Distribucion de la Comision Federal de Electricidad (CFE) en dos procesos por separado: elaboracion de planos de ingenieria con software para diseno asistido por computadora (CAD, Computer-Aided Design) y calculo de la volumetria para la elaboracion del presupuesto base, con hojas de calculo convencionales. Los documentos se elaboran manualmente y de forma individual, sin existir alguna funcionalidad que permita actualizar automaticamente las modificaciones del diseno en todos los planos, y el correspondiente presupuesto base, resultando un proceso tardado, laborioso y factible de inconsistencia entre los documentos. Con la finalidad de optimizar el proceso de diseno de la obra civil y electromecanica de subestaciones electricas (SE) en un ambiente grafico tridimensional (3D), la Gerencia de Supervision de Proceso del Instituto de Investigaciones Electricas (IIE), en coordinacion con la Subdireccion de Distribucion de la CFE, desarrollo el Sistema para el Diseno de Subestaciones Electricas de Distribucion (DiDSED), el cual aprovecha las ventajas de la tecnologia CAD3D para el desarrollo de la ingenieria de detalle, ingenieria de costos para el calculo del presupuesto base y realidad virtual para navegacion tridimensional interactiva. Cabe destacar que actualmente, este sistema se encuentra en la etapa de implantacion en la Subdireccion de Distribucion de la CFE. En este articulo se describen brevemente las etapas principales del desarrollo del proyecto, asi como la funcionalidad y los componentes principales del sistema.

  5. Revista Investigacion Educativa, 1992-1995.

    Science.gov (United States)

    Revista Investigacion Educativa, 1995

    1995-01-01

    This document consists of the eight issues of the series "Revista Investigacion Educativa" published during the 4-year period 1992-1995. This review of educational investigation seeks to promote the exchange of information about empirical research in education. It is published semiannually, and includes reports of both quantitative and…

  6. Sun, wind and electric generation; Sol, viento y generacion electrica

    Energy Technology Data Exchange (ETDEWEB)

    Huacuz Villamar, Jorge M. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1995-12-31

    A description is made of the electric generation known as the photovoltaic-wind power hybrid systems at the generation station of X-Calak which is located in the zone known as Punta Herrero-X-Calak Corridor, in the Southern coast of the Quintana Roo State. This is a technology in development, in which the solar and the wind energy are combined, to offer an alternative of electric generation that can be economical, reliable and of low impact on the environment. Mention is made of the experiences gathered in this station as well as the results obtained [Espanol] Se describe la tecnologia de generacion electrica conocida como sistemas hibridos fotovoltaico-eolico en la planta generadora de X-Calak, la cual esta localizada en la zona conocida como el corredor Punta Herrero-X-Calak, en la costa sur del estado de Quintana Roo. Esta es una tecnologia en desarrollo, en donde se combina la energia solar y energia eolica, para ofrecer una alternativa de generacion electrica que pretende ser economica, confiable y de bajo impacto sobre el medio ambiente. Se mencionan las experiencias obtenidas en esta planta asi como los resultados obtenidos

  7. La investigacion social cualitativa en Mexico

    OpenAIRE

    Cisneros Puebla, Cesar A.; Universidad Autónoma Metropolitana Iztapalaga

    2014-01-01

    En la ultima decada se ha incrementado el interes en torno a la aplicacion de las metodologias interpretativas. La medicina, la sociologia y la psicologia social son las disciplinas en las que se distingue una mayor influencia. Similar a la situacion de otros paises de Latinoamerica, en Mexico no se ha profesionalizado el ejerciciode todos los campos de accion cientifico. La investigacion social cualitativa en Mexico esta pasando de la observacion participante y la ocial cualitativa en Mexico...

  8. System for the measurement and detection of electric energy losses (SIM-IV); Sistema de medicion y deteccion de perdidas de energia electrica (SIM-IV)

    Energy Technology Data Exchange (ETDEWEB)

    Vidrio L, Gilberto; Gomez L, Martin J; Castan L, Roberto [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2004-07-01

    The electric utility companies worldwide suffer, in greater or lesser degree, electrical energy losses. A great percentage of these losses is mostly due to illegal appropriations of energy. The consumers, by means of illicit practices such as clandestine connections and alteration of the operation of electricity meters, carry out the energy robbery. In order to try to alleviate the problematic of electric energy losses, in their majority by illicit, the electric utility companies have implemented one or more actions. Among the most important are: Visual inspection of the metering facilities. Its purpose is to verify the condition of the traditional protections of the metering installations, such as the seals and safety rings. Detection Equipment: These are recorders of energy consumption and of faults in conductors and are used to detect illicit connections and deviations in the consumption patterns and to the electrical energy connection or to the secondary distribution network. Statistical analysis of consumption: Many electric facility companies have adapted their processing consumption reading systems to detect deviations in the of consumption patterns of their clients. This could correspond to abnormal situations. Since this country is not extraneous to the problematic of energy losses, in the Instituto de Investigaciones Electricas it was developed a System of Measurement and Detection of Losses of Electrical Energy (SIM-IV) as a result of the knowledge of the problematic obtained from the projects in the metering area and of the interaction through work meetings with personnel of the Comision Federal de Electricidad and of Luz y Fuerza del Centro (LyFC), in which concepts of advanced technology were applied for the measurement of electrical variables. The SIM-IV is a system oriented to the metering of consumption and the detection of robberies of electrical energy caused by clandestine connections and non-allowed interventions to the energy meters. Since

  9. Multidimensionality in Fluidized Nanopowder Agglomerates

    NARCIS (Netherlands)

    De Martin, L.; Bouwman, W.G.; Van Ommen, J.R.

    2013-01-01

    recent years, the interest in fluidization as a mean to process nanoparticles is strongly increasing. Due to the small size of the nanoparticles, which makes van der Waals forces predominate, they do not fluidize as single particles but as agglomerates. Various researchers using settling experiments

  10. Fluidized-bed nuclear reactor

    International Nuclear Information System (INIS)

    Grimmett, E.S.; Kunze, J.F.

    1975-01-01

    A reactor vessel containing a fluidized-bed region of particulate material including both a neutron-moderating and a fertile substance is described. A gas flow including fissile material passes through the vessel at a sufficient rate to fluidize the particulate material and at a sufficient density to support a thermal fission reaction within the fluidized-bed region. The high-temperature portion of a heat transfer system is located within the fluidized-bed region of the reactor vessel in direct contact with the fluidized particles. Heat released by fission is thereby transferred at an enhanced rate to a coolant circulating within the heat transfer system. Fission products are continuously removed from the gas flow and supplemental fissile material added during the reactor operation. (U.S.)

  11. Pyrolysis of corncobs at fluidization

    Energy Technology Data Exchange (ETDEWEB)

    Hongming Jiang; Morey, R.V. (Minnesota Univ., St. Paul, MN (United States). Dept. of Agricultural Engineering)

    1992-01-01

    Pyrolysis of corncob particles was conducted in nitrogen in an externally heated benchscale fluidized bed reactor. Test results are presented with a demonstration of their application in gasification modelling. (author).

  12. Calculation of the electromagnetic fields in electric machines through the use of the finite element. Algorithms for the solution of induction problems. Pt. 3; Calculo de campos electromagneticos en maquinas electricas mediante elemento finito. Algoritmos para la solucion de problemas de induccion. Pt. 3

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, Mario F. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    This article is based in the electromagnetic modeling presented in the first part of the series for the indirect solution of partial differential equations. Magnetic systems in closed regions with moving or axial symmetry, whose total current density is partially known (induction problems) are considered. Includes the ability to deal with means in movement and a sinusoidal behavior for the source density current is assumed. Some algorithms are developed that are implanted in the software CALIIE-2D of the Instituto de Investigaciones Electricas (IIE) to obtain the numerical solutions of these problems. The basic systems of algebraic equations are obtained through the application of the Galerkin method in the discreteness of the finite element with first order triangular elements. [Espanol] Este articulo se basa en la modelacion electromagnetica presentada en la primera parte de la serie y en el planteamiento proporcionado en la segunda parte para la solucion indirecta de ecuaciones diferenciales parciales. Se consideran sistemas magneticos en regiones cerradas con simetria traslacional o axial, cuya densidad de corriente total es parcialmente conocida (problemas de induccion). Incluye la capacidad para tratar medios con movimiento y se supone un comportamiento senoidal para la densidad de corriente fuente. Se desarrollan los algoritmos que se implantan en el programa de computo CALIIE-2D del Instituto de Investigaciones Electricas (IIE) para obtener las soluciones numericas de estos problemas. Los sistemas basicos de ecuaciones algebraicas se obtienen mediante la aplicacion del metodo de Galerkin en la discretizacion de elemento finito con elementos triangulares de primer orden.

  13. Multidimensionality in fluidized nanopowder agglomerates

    Science.gov (United States)

    Martín, Lilian de; Bouwman, Wim G.; van Ommen, J. Ruud

    2013-06-01

    In recent years, the interest in fluidization as a mean to process nanoparticles is strongly increasing. Due to the small size of the nanoparticles, which makes van der Waals forces predominate, they do not fluidize as single particles but as agglomerates. Various researchers using settling experiments and bed expansion measurements conclude that fluidized agglomerates are fractal structures with a single fractal dimension of 2.5. Based on microscopy results, Wang et al. ``Powder Technology 124, 152-C159 (2002)'' propose a hierarchical structure, which seems in contradiction with the use of only one fractal dimension as a descriptor of the whole structure. Moreover, it is not clear whether the structure presented by the agglomerates ex-situ is the same during fluidization. Hence, in this work we have characterized in-situ the internal structure of fluidized agglomerates by means of spin-echo small-angle neutron scattering (SESANS). We show that the structure of the agglomerates present at least two fractal dimensions. One of them is ~= 2.1 and characterizes the primary strong agglomerates. The second one is ~= 2.8 and characterizes the larger agglomerates formed by the primary agglomerates.

  14. de investigaciones científicas

    Directory of Open Access Journals (Sweden)

    Stephany Laguna Sanjuanelo

    2007-01-01

    Full Text Available En este trabajo se explican de manera amplia las violaciones éticas que se cometen con mayor frecuencia al momento de publicar artículos científicos ya sea porque no se tiene el conocimiento necesario o porque se “cree” necesario realizarlas. Se hace referencia al proceso editorial y la parte ética que éste conlleva, el concepto de autoría y los criterios existentes para denominar a una persona “autora” de un artículo, además de explicar el proceso de revisión por pares por el cual pasan todas las investigaciones para su validación antes de ser publicadas. También se analizan las violaciones éticas más comunes y fáciles de cometer si no se tiene el conocimiento, como son el plagio y la publicación duplicada, y se adjuntan guías prácticas para evitar cometerlas. Por último hablamos de consideraciones finales que se deben tener en cuenta antes de publicar artículos, tales como los conflictos de interés y el consentimiento informado, los cuales son muy importantes al momento de validar la información que se presente en el artículo en cuestión.

  15. Research on heat pumps in Mexico operating with geothermal energy and waste heat; Investigacion sobre bombas de calor en Mexico operando con energia geotermica y calor de desecho

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Gutierrez, A; Barragan-Reyes, R.M; Arellano-Gomez, V [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)]. E-mail: aggarcia@iie.org.mx

    2008-01-15

    The Instituto de Investigaciones Electricas and the Comision Federal de Electricidad have done research and development (R&D) on heat pumps (HP) in past years. Tested systems include mechanical compression, absorption and heat-transformers. The main R&D aspects on HP are briefly described, and also a more detailed description about three of the main studies is presented: (a) a mechanical compression HP of the water-water type operated with low-pressure geothermal steam at the Los Azufres; Mich., geothermal field, and designed for purification of brine; (b) an absorption HP for cooling and refrigeration operating with ammonia-water and low-enthalpy geothermal energy, which was tested in the Los Azufres and Cerro Prieto, BC, geothermal fields; and (c) a heat-transformer by absorption-Absorption Heat Pump Type II-tested to assess the performance of several ternary solutions as work fluids. Plans exist to install and test a geothermal heat pump at Cerro Prieto or Mexicali, BC. [Spanish] El Instituto de Investigaciones Electricas y la Comision Federal de Electricidad han realizado trabajo de investigacion y desarrollo (I&D) sobre bombas de calor (BC) en el pasado. Los sistemas probados incluyen compresion mecanica, absorcion y transformadores termicos. Este trabajo describe brevemente los principales aspectos de I&D sobre bombas de calor en forma general, y se da una descripcion mas detallada de tres de los principales estudios: (a) una BC por compresion mecanica tipo agua-agua disenada para purificacion de salmueras operando con vapor geotermico de baja presion en el campo geotermico de Los Azufres, Mich.; (b) una BC por absorcion para enfriamiento y refrigeracion operando con amoniaco-agua y energia geotermica de baja entalpia, la cual fue probada en los campos geotermicos de Los Azufres y Cerro Prieto, BC; y (c) un transformador termico por absorcion -llamado Bomba de Calor por Absorcion Tipo II--, el cual fue probado para evaluar el comportamiento de diversas

  16. Research and technological development on heat pumps in Mexico operating with geothermal energy; Investigacion y desarrollo tecnologico sobre bombas de calor en Mexico operando con energia geotermica

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Gutierrez, Alfonso; Barragan Reyes, Rosa Maria; Arellano Gomez, Victor Manuel [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2008-07-01

    The Instituto de Investigaciones Electricas (IIE) and the Comision Federal de Electricidad (CFE) carried out in the past an extensive work of research and development (R&D) on heat pumps (HP). The systems tried on include heat pumps by mechanical compression, thermal absorption and thermal transformers. This paper briefly describes the main aspects of R&D on heat pumps and presents a more detailed description of three of the main studies: a) a Heat Pump (HP) by mechanical compression water-water type, designed for brine purification, operating with low pressure geothermal steam at the geothermal field Los Azufres, Michoacan, Mexico; b) a HP by absorption for cooling and refrigeration, operating with ammoniac/water and low enthalpy geothermal energy, which was tested in the geothermal fields of Los Azufres, Michoacan and Cerro Prieto, Baja California, and c) a thermal transformer by absorption, named Heat Pump by Absorption Type 2, which was tested to evaluate the behavior of diverse ternary solutions as working fluids. To date, there are plans to install and test a geothermal heat pump (connected to the subsoil), in Cerro Prieto, Mexicali, Baja California, Mexico. [Spanish] El Instituto de Investigaciones Electricas (IIE) y la Comision Federal de Electricidad (CFE) realizaron un trabajo extenso de investigacion y desarrollo (I&D) sobre bombas de calor (BC) en el pasado. Los sistemas que se probaron incluyen bombas de calor por compresion mecanica, absorcion y transformadores termicos. Este trabajo describe brevemente los principales aspectos de I&D sobre bombas de calor y se da una descripcion mas detallada de tres de los principales estudios: a) una Bomba de Calor (BC) por compresion mecanica tipo agua-agua, disenada para purificacion de salmueras, operando con vapor geotermico de baja presion en el campo geotermico de Los Azufres, Michoacan; b) una BC por absorcion para enfriamiento y refrigeracion, operando con amoniaco/agua y energia geotermica de baja entalpia

  17. Apparatus and process for controlling fluidized beds

    Science.gov (United States)

    Rehmat, Amirali G.; Patel, Jitendra G.

    1985-10-01

    An apparatus and process for control and maintenance of fluidized beds under non-steady state conditions. An ash removal conduit is provided for removing solid particulates from a fluidized bed separate from an ash discharge conduit in the lower portion of the grate supporting such a bed. The apparatus and process of this invention is particularly suitable for use in ash agglomerating fluidized beds and provides control of the fluidized bed before ash agglomeration is initiated and during upset conditions resulting in stable, sinter-free fluidized bed maintenance.

  18. Photovoltaic systems interconnected to the electric network; Sistemas fotovoltaicos interconectados a la red electrica

    Energy Technology Data Exchange (ETDEWEB)

    Agredano Diaz, Jaime [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2007-06-15

    . Enseguida, se muestra la solucion que le encontro el Gobierno del Estado a este problema para lo que fue necesaria la participacion del Instituto de Investigaciones Electricas (IIE). Esta participacion, se traduce en un proyecto que muestra la viabilidad de instalar sistemas fotovoltaicos interconectados a la red de la Comision Federal de Electricidad (CFE) en casas habitacion. Despues, se presenta una descripcion no solo de los elementos que conforman el sistema, sino tambien de la metodologia y el funcionamiento del mismo. Posteriormente, se presenta el efecto positivo, economicamente y ambientalmente hablando, que tuvo la instalacion del sistema en las 220 casas habitacion del fraccionamiento Valle de las Misiones, asi como las caracteristicas generales del mismo. Ademas, se presenta la manera de alcanzar un mayor impacto y cobertura del sistema. Finalmente, se presentan los auspiciadotes del proyecto: la Secretaria de Energia (SENER), la CFE, la Comision Reguladora de Energia (CRE), la Universidad Autonoma de Baja California (UABC), el IIE, el Banco de Desarrollo de America del Norte (BDAN) y el Gobierno del Estado de Baja California.

  19. IEN project - Fluidized bed burner

    International Nuclear Information System (INIS)

    1985-08-01

    Due to difficulties inherent to the organic waste storage from laboratories and institutes which use radioactive materials for scientific researches, the Nuclear Facilities Division (DIN/CNEN); elaborated a project for constructing a fluidized burner, in laboratory scale, for burning the low level organic radioactive wastes. The burning system of organic wastes is described. (M.C.K.) [pt

  20. Fluidization of Dried Wastewater Sludge.

    Czech Academy of Sciences Publication Activity Database

    Hartman, Miloslav; Pohořelý, Michael; Trnka, Otakar

    2007-01-01

    Roč. 178, 3 (2007) , s. 166-172 ISSN 0032-5910 R&D Projects: GA AV ČR(CZ) IAA4072201 Institutional research plan: CEZ:AV0Z40720504 Keywords : fluidization characteristics * multiphase reactors * dried stabilized wastewater sludge Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.130, year: 2007

  1. Annual Report 1995. Direccion de Investigacion y Desarrollo

    International Nuclear Information System (INIS)

    1995-01-01

    In this report, the main results of the projects, studies, services and departmental activities of the Direccion de Investigacion y Desarrollo of the Instituto Nacional de Investigaciones Nucleares (ININ), during 1995, are shown. It includes the results of different areas such as Nuclear Chemistry and Physics, Environmental Science and Genetics, Radiobiology, Nuclear Technology, Nuclear Fuel and Technical Assistance, as well as their main objectives, stage of development and publications. (Author)

  2. La porcelana del Buen Retiro. Investigaciones recientes

    Directory of Open Access Journals (Sweden)

    Mañueco Santurtún, C.

    1999-08-01

    Full Text Available Recent researchs have led to know new data of the construction of the Royal Porcelain Factory of Buen Retiro (Madrid, Spain. As some documents not known hitherto have revealed, the Factory was integrated by two different buildings. It was known that the building for the workrooms was raised up in 1760 –from January to May-. The economic cost traditionally atributted to this construction has resulted to be the total cost of a second building, raised in a period of five years –until August of 1765- to be occupied by the workers and their families. A second aspect studied in these pages is about the iconographic sources on which may be based some porcelain works made at the Factory.

    En este trabajo se dan a conocer los resultados de investigaciones recientes sobre La Real Fábrica de Porcelana del Buen Retiro (1760-1808 que abordan dos temas. El primero, referido a la construcción de la Fábrica. Datos documentales inéditos han permitido conocer que la Manufactura del Buen Retiro fue un complejo en el que hubo dos edificaciones: de la más antigua, destinada a contener los talleres de la Fábrica, siempre se ha sabido que se construyó en cinco meses (enero, mayo 1760, aunque el costo de esta obra no coincida con el que tradicionalmente se le ha venido atribuyendo. Pero no se tenía noticia de la existencia de una segunda edificación, cuyas obras duraron cinco años y finalizaron en agosto de 1765. Este edificio estuvo destinado a albergar a los operarios de la Fábrica y su costo, muy elevado, corresponde con el que siempre se ha venido asignando a los talleres de la Fábrica. El segundo apartado se ha dedicado a mostrar las fuentes iconográficas de algunas realizaciones de porcelana de la Manufactura madrileña.

  3. Advances in fluidized bed technologies

    International Nuclear Information System (INIS)

    Mutanen, K.

    1992-01-01

    Atmospheric fluidized bed combustion (AFBC) has advanced into industrial cogeneration and utility-scale electric generation. During the 1980's AFBC became the dominant technology in the United States for power generation systems fired with solid fuels. Development of pressurized fluidized bed combustion/gasification (PFB/G) has grown rapidly from small bench-scale rigs to large pilot and demonstration plants. AFBC as large as 160 MWe in capacity are now in operation, while pressurized combustion systems generating 80 MWe have started up two years ago. The major driving forces behind development of fluidized bed technologies are all the time strictening emission control regulations, need for fuel flexibility, repowering of older power plants and need for higher efficiency in electricity generation. Independent power producers (IPP) and cogenerators were the first ones in the United States who accepted AFBC for wide commercial use. Their role will be dominant in the markets of the 1990's also. Developers of AFBC systems are working on designs that reduce investment costs, decrease emissions and offer even higher reliability and availability in utility-scale applications while developers of PFBC/G work on designs that increase plant efficiencies, allow modular construction, decrease emissions further and reduce the cost of generating power. This paper presents technological background, commercial status, boiler performance, emissions and future developments for both AFBC and PFBC/G systems

  4. ELECTRICA: ELEctronic knowledge base for Clinical care, Teaching and Research In Child Abuse.

    Science.gov (United States)

    Offiah, Amaka; Hume, Jessica; Bamsey, Ian; Jenkinson, Howard; Lings, Brian

    2011-11-01

    Child abuse is a highly significant public health issue with 4-16% of children being physically abused. The diagnosis is sensitive and challenging, with many radiologists dissatisfied with current levels of training and support. The literature shows a lack of prospective scientific research in this complex field. An ELEctronic knowledge base for Clinical care, Teaching and Research In Child Abuse (ELECTRICA) should solve many current problems. ELECTRICA will be populated with clinical information, radiographs and radiographic findings in children younger than 3 years of age presenting with injury (accidental or suspected abuse), to form a unique resource. This web-based tool will unify the investigative protocol in suspected abuse and support training and allow multicentre national and international collaborative research and provide robust evidence to support the legal process.

  5. EDUCACIÓN, MAESTROS EN TIEMPOS RECIENTES. TRES INVESTIGACIONES

    OpenAIRE

    José G. Viloria Asención

    2010-01-01

    El conjunto de reflexiones que se presentan, responden a los esfuerzos realizados durante el desarrollo de tres Investigaciones sobre la Educación, la Pedagogía y sus prácticas, durante la última mitad del siglo XX e inicios del sigloXXI. Las Investigaciones se asumieron desde un enfoque fenomenológicointerpretativo, lo que permitió otorgar la palabra a los testigos presenciales e informantes de primera fuente sobre el asunto en estudio. Los métodos empleados fueron la Entrevista en Profundid...

  6. ORGANIZACIÓN DE UN INSTITUTO UNIVERSITARIO DE INVESTIGACIONES CONTABLES

    OpenAIRE

    Biondi, Mario; Universidad de Buenos Aires; Wainstein, Mario; Universidad de Buenos Aires

    2014-01-01

    Consideramos importante transcribir el presente artículo, publicado en la Revista Contabilidad y Auditoría -diciembre 2001- del Instituto de Investigaciones Contables •Prof. Juan Alberto Arévalo• de la Facultad de Ciencias Económicas de la Universidad de Buenos Aires, Argentina, que nos permite conocer los alcances que tiene un Instituto de Investigaciones Contables, como un estímulo para seguir este ejemplo de desarrollo y satisfacer nuestra inquietante posición de docentes universitarios de...

  7. Flue Gas Emissions from Fluidized Bed Combustion

    NARCIS (Netherlands)

    Bramer, E.A.; Valk, M.

    1995-01-01

    During the past decades fluidized bed coal combustion was developed as a technology for burning coal in an effective way meeting the standards for pollution control. During the earlier years of research on fluidized bed combustion, the potential for limiting the S02 emission by adding limestone to

  8. Fluidized bed silicon deposition from silane

    Science.gov (United States)

    Hsu, George (Inventor); Levin, Harry (Inventor); Hogle, Richard A. (Inventor); Praturi, Ananda (Inventor); Lutwack, Ralph (Inventor)

    1984-01-01

    A process and apparatus for thermally decomposing silicon containing gas for deposition on fluidized nucleating silicon seed particles is disclosed. Silicon seed particles are produced in a secondary fluidized reactor by thermal decomposition of a silicon containing gas. The thermally produced silicon seed particles are then introduced into a primary fluidized bed reactor to form a fludized bed. Silicon containing gas is introduced into the primary reactor where it is thermally decomposed and deposited on the fluidized silicon seed particles. Silicon seed particles having the desired amount of thermally decomposed silicon product thereon are removed from the primary fluidized reactor as ultra pure silicon product. An apparatus for carrying out this process is also disclosed.

  9. Continuous austempering fluidized bed furnace. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Srinivasan, M.N. [Lamar Univ., Beaumont, TX (United States). Dept. of Mechanical Engineering

    1997-09-23

    The intended objective of this project was to show the benefits of using a fluidized bed furnace for austenitizing and austempering of steel castings in a continuous manner. The division of responsibilities was as follows: (1) design of the fluidized bed furnace--Kemp Development Corporation; (2) fabrication of the fluidized bed furnace--Quality Electric Steel, Inc.; (3) procedure for austempering of steel castings, analysis of the results after austempering--Texas A and M University (Texas Engineering Experiment Station). The Department of Energy provided funding to Texas A and M University and Kemp Development Corporation. The responsibility of Quality Electric Steel was to fabricate the fluidized bed, make test castings and perform austempering of the steel castings in the fluidized bed, at their own expense. The project goals had to be reviewed several times due to financial constraints and technical difficulties encountered during the course of the project. The modifications made and the associated events are listed in chronological order.

  10. Electric grid in Spain: a private network of optical fiber with national coverage; Red electrica de Espana: una red privada de fibra optica con cobertura nacional

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, A.

    1995-12-31

    Red Electrica constructed a grid with optical fiber in 1989 for the grids of 400-220 Kv. In 1995 the length of the grid will be of 6.600 Km. This grid supplies the telecommunication advanced services and contributes in the efficiency and quality of different tasks of Red Electrica.

  11. Heat and mass transfer enforcement of vibrating fluidized bed

    Science.gov (United States)

    Chu, Zhide; Yang, Junhong; Li, Xuhui; Song, Yang

    1994-12-01

    This paper briefly introduces the development of vibrating fluidized bed at home and abroad, elaborates the vibration properties of vibrating fluidized bed, the fluidizing velocity and pressure drop of the bed layer. It also deduces the non-steady state drying dynamic equations of vibrating fluidized bed, analyzes main factors which influence the drying rate and inquires into drying rules of fixed bed and vibrating fluidized bed.

  12. Characterization of fluidization regime in circulating fluidized bed reactor with high solid particle concentration using computational fluid dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Chalermsinsuwan, Benjapon; Thummakul, Theeranan; Piumsomboon, Pornpote [Chulalongkorn University, Bangkok (Thailand); Gidaspow, Dimitri [Armour College of Engineering, Chicago (United States)

    2014-02-15

    The hydrodynamics inside a high solid particle concentration circulating fluidized bed reactor was investigated using computational fluid dynamics simulation. Compared to a low solid particle reactor, all the conventional fluidization regimes were observed. In addition, two unconventional fluidization regimes, circulating-turbulent and dense suspension bypassing regimes, were found with only primary gas injection. The circulating-turbulent fluidization regime showed uniformly dense solid particle distribution in all the system directions, while the dense suspension bypassing fluidization regime exhibited the flow of solid particles at only one side system wall. Then, comprehensive fluidization regime clarification and mapping were evaluated using in-depth system parameters. In the circulating-turbulent fluidization regime, the total granular temperature was low compared to the adjacent fluidization regimes. In the dense suspension bypassing fluidization regime, the highest total granular temperature was obtained. The circulating-turbulent and dense suspension bypassing fluidization regimes are suitable for sorption and transportation applications, respectively.

  13. Recent advances in fluidized bed drying

    Science.gov (United States)

    Haron, N. S.; Zakaria, J. H.; Mohideen Batcha, M. F.

    2017-09-01

    Fluidized bed drying are very well known to yield high heat and mass transfer and hence adopted to many industrial drying processes particularly agricultural products. In this paper, recent advances in fluidized bed drying were reviewed and focus is given to the drying related to the usage of Computational Fluid Dynamics (CFD). It can be seen that usage of modern computational tools such as CFD helps to optimize the fluidized bed dryer design and operation for lower energy consumption and thus better thermal efficiency. Among agricultural products that were reviewed in this paper were oil palm frond, wheat grains, olive pomace, coconut, pepper corn and millet.

  14. Fluidization calculation on nuclear fuel kernel coating

    International Nuclear Information System (INIS)

    Sukarsono; Wardaya; Indra-Suryawan

    1996-01-01

    The fluidization of nuclear fuel kernel coating was calculated. The bottom of the reactor was in the from of cone on top of the cone there was a cylinder, the diameter of the cylinder for fluidization was 2 cm and at the upper part of the cylinder was 3 cm. Fluidization took place in the cone and the first cylinder. The maximum and the minimum velocity of the gas of varied kernel diameter, the porosity and bed height of varied stream gas velocity were calculated. The calculation was done by basic program

  15. The photovoltaic generators and the electric network; Los generadores fotovoltaicos y la red electrica

    Energy Technology Data Exchange (ETDEWEB)

    Arteaga Novoa, Oscar E.; Agredano Diaz, Jaime; Huacuz Villamar, Jorge M. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    The photovoltaic generators are analyzed as an option for the electricity supply. An analysis is made of the option that these systems be utilized in sites where it is difficult to extend the power lines an in sites where the electric service already exists, such as residences, commercial buildings, network support power stations, central power stations, all this in order that the photovoltaic systems interact with the electric network for the generation of part of the energy consumed in these sites. In order that the photovoltaic systems can be interconnected with the electric network it is required: energy quality, protection and safety of the systems and persons and normativity for the interconnection. Some of the national programs of countries like Japan, United States of America and some organs of the Commission of the European Community are described. In conclusion, it is expected that the costs of this technology decrease so these systems can be widely utilized [Espanol] Se analizan los generadores fotovoltaicos como una alternativa para el suministro electrico. Se analiza la opcion de que estos sistemas se utilicen en lugares en donde es dificil extender la red electrica y en sitios en donde el servicio electrico ya existe, tales como: residencias, edificios comerciales, estaciones de apoyo a la red, estaciones centrales, esto con la finalidad de que el sistema fotovoltaico interactue con la red electrica a fin de generar parte de la energia que se consume en estos sitios. Para que los sistemas fotovoltaicos puedan estar interconectados con la red electrica se requiere: calidad de la energia, proteccion y seguridad de los sistemas y personas, y normatividad para la interconexion. Se describen algunos programas nacionales de paises como Japon, Estados Unidos y algunos organismos de la Comision de Comunidades Europeas. En conclusion, se espera que los costos de esta tecnologia disminuyan para que estos sistemas puedan ser ampliamante utilizados

  16. Standardization for electric energy saving; Normalizacion para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Reyes Diaz, Arturo [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE), Mexico, D. F. (Mexico)

    1993-12-31

    This work describes shortly the current legislation on the standardization; as well as the participation of the entities Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE) and Programa de Ahorro de Energia (PAESE) in the consulting committees, for the elaboration of the Mexican official standards focussed to electric power saving. [Espanol] El presente trabajo, describe brevemente la legislacion actual sobre la normalizacion; asi como la participacion de las entidades Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE) y Programa de ahorro de Energia (PAESE) en los comites consultivos, para la elaboracion de normas oficiales mexicanas enfocadas al ahorro de energia electrica.

  17. Violencia en el trabajo: investigaciones realizadas en Colombia

    Directory of Open Access Journals (Sweden)

    José Gabriel Carvajal Orozco

    2013-12-01

    Full Text Available El propósito de esta ponencia es mostrar los resultados de una exploración bibliográfica concerniente a las investigaciones llevadas a cabo en los últimos diez años, sobre el tema de la violencia en el lugar de trabajo. Se consultaron 16 artículos –5 empíricos, 11 teóricos–, publicados en revistas científicas colombianas, en universidades públicas y privadas, en instituciones gubernamentales y en bases de datos académicas. La ponencia está estructurada en tres partes: la primera presenta los aspectos metodológicos; la segunda expone los resultados de la exploración, donde se muestran las problemáticas que se han abordado en las investigaciones sobre violencia en el trabajo, y la tercera y última parte contiene las conclusiones acerca de los resultados obtenidos.

  18. Fluidization technologies: Aerodynamic principles and process engineering.

    Science.gov (United States)

    Dixit, Rahul; Puthli, Shivanand

    2009-11-01

    The concept of fluidization has been adapted to different unit processes of pharmaceutical product development. Till date a lot of improvements have been made in the engineering design to achieve superior process performance. This review is focused on the fundamental principles of aerodynamics and hydrodynamics associated with the fluidization technologies. Fluid-bed coating, fluidized bed granulation, rotor processing, hot melt granulation, electrostatic coating, supercritical fluid based fluidized bed technology are highlighted. Developments in the design of processing equipments have been explicitly elucidated. This article also discusses processing problems from the operator's perspective along with latest developments in the application of these principles. (c) 2009 Wiley-Liss, Inc. and the American Pharmacists Association

  19. Lipid encapsulated phenolic compounds by fluidization

    Science.gov (United States)

    Phenolic compounds exhibit antioxidant and antimicrobial activities with applications as functional food and feed additives. Ferulic acid, a phenolic compound present in grain crops and lignocellulose biomass, was encapsulated with saturated triglycerides using a laboratory fluidizer. Stability of t...

  20. Pulsed atmospheric fluidized bed combustion

    Energy Technology Data Exchange (ETDEWEB)

    1989-11-01

    In order to verify the technical feasibility of the MTCI Pulsed Atmospheric Fluidized Bed Combustor technology, a laboratory-scale system was designed, built and tested. Important aspects of the operational and performance parameters of the system were established experimentally. A considerable amount of the effort was invested in the initial task of constructing an AFBC that would represent a reasonable baseline against which the performance of the PAFBC could be compared. A summary comparison of the performance and emissions data from the MTCI 2 ft {times} 2 ft facility (AFBC and PAFBC modes) with those from conventional BFBC (taller freeboard and recycle operation) and circulating fluidized bed combustion (CFBC) units is given in Table ES-1. The comparison is for typical high-volatile bituminous coals and sorbents of average reactivity. The values indicated for BFBC and CFBC were based on published information. The AFBC unit that was designed to act as a baseline for the comparison was indeed representative of the larger units even at the smaller scale for which it was designed. The PAFBC mode exhibited superior performance in relation to the AFBC mode. The higher combustion efficiency translates into reduced coal consumption and lower system operating cost; the improvement in sulfur capture implies less sorbent requirement and waste generation and in turn lower operating cost; lower NO{sub x} and CO emissions mean ease of site permitting; and greater steam-generation rate translates into less heat exchange surface area and reduced capital cost. Also, the PAFBC performance generally surpasses those of conventional BFBC, is comparable to CFBC in combustion and NO{sub x} emissions, and is better than CFBC in sulfur capture and CO emissions even at the scaled-down size used for the experimental feasibility tests.

  1. Fluidized-bed reactors processes and operating conditions

    CERN Document Server

    Yates, John G

    2016-01-01

    The fluidized-bed reactor is the centerpiece of industrial fluidization processes. This book focuses on the design and operation of fluidized beds in many different industrial processes, emphasizing the rationale for choosing fluidized beds for each particular process. The book starts with a brief history of fluidization from its inception in the 1940’s. The authors present both the fluid dynamics of gas-solid fluidized beds and the extensive experimental studies of operating systems and they set them in the context of operating processes that use fluid-bed reactors. Chemical engineering students and postdocs as well as practicing engineers will find great interest in this book.

  2. Flow Pattern in a Fluidized Bed with a Non-fluidized Zone

    DEFF Research Database (Denmark)

    Lin, Weigang; Dam-Johansen, Kim; Van den Bleek, Cor. M.

    1997-01-01

    The flow pattern of a fluidized bed with non-fluidized zones is investigated both experimentally and theoretically. Experiments were carried out in such a way that air was introduced only through part of the distributor. The results show a significant amount of air flowing to the zone where no ai...

  3. Research and development of hydrogen and fuel cells technology at the IIE; Investigacion y desarrollo de tecnologia de hidrogeno y celdas de combustible en el IIE

    Energy Technology Data Exchange (ETDEWEB)

    Cano C, Ulises; Arriaga H, Gerardo; Romero C, T; Medrano V, M. Consolacion; Gonzalez, A. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2005-07-01

    In April, 2001, a fuel cells project was initiated at the Instituto de Investigaciones Electricas (IIE) as a part of the interest of this institution for such a technology. Towards end of that same year, a group dedicated to research and development (R and D) activities was implemented and efforts were initiated for the assembly of a laboratory with specialized infrastructure that would support these activities. Thus, in the last two years, the hydrogen and fuel cells group has taken under its responsibility the task of renewing and conditioning a space to receive specialized instrumentation and to initiate its operation, as well as to develop its own knowledge on the technology of fuel cells. The R and D work related to fuel cells was initiated from basic electrochemical studies of platinum electrodes on vitreous coal in acid solutions, to determine kinetic parameters and structural properties. Since the main components of PEM cells to a great extent define the cost of the technology, other additional efforts related to basic studies for the development of components as bipolar plates, are described by the same author in 2001. Other work on basic research is bound to the response of fuel monocells under different operation conditions, and that also will be reviewed in this article. [Spanish] En abril del 2001, se inicio un proyecto de celdas de combustible en el IIE como parte del interes de esta institucion por tal tecnologia. Hacia finales de ese mismo ano, se conformo un grupo dedicado a actividades de investigacion y desarrollo (I y D) y se iniciaron esfuerzos para el montaje de un laboratorio con infraestructura especializada que apoyara estas actividades. Asi, en los ultimos dos anos, el grupo de hidrogeno y celdas de combustible se ha dado a la tarea de renovar y acondicionar un espacio para recibir instrumentacion especializada e iniciar su operacion, asi como a desarrollar su propio conocimiento de tecnologia de celdas de combustible. Los trabajos de I y

  4. Fluidization of Group B particles with a rotating distributor

    OpenAIRE

    Sobrino Fernández, Celia; Almendros Ibáñez, José Antonio; Santana Santana, Domingo José; Vega Blázquez, Mercedes de

    2008-01-01

    A novel rotating distributor fluidized bed is presented. The distributor is a rotating perforated plate, with 1% open-area ratio. This work evaluates the performance of this new design, considering pressure drop, Δp, and quality of fluidization. Bed fluidization was easily achieved with the proposed device, improving the solid mixing and the quality of fluidization. In order to examine the effect of the rotational speed of the distributor plate on the hydrodynamic behavior of the bed...

  5. 3D As-Built a documentation of the substation electrical power 400 KV; Documentacion 3D As-Built de una subestacion electrica de 400 KV

    Energy Technology Data Exchange (ETDEWEB)

    Sarti Fernandez, F.

    2011-07-01

    It's getting parameters of time, yields and products obtained, in order to have an objective reference to the possible application of this technique to substations of Red Electrica Espanola (REE).

  6. Fluidization behavior in a circulating slugging fluidized bed reactor. Part I: Residence time and residence time distribution of polyethylene solids

    NARCIS (Netherlands)

    van Putten, I.C.; van Sint Annaland, M.; Weickert, G.

    2007-01-01

    Square nosed slugging fluidization behavior in a circulating fluidized bed riser using a polyethylene powder with a very wide particle size distribution was studied. In square nosed slugging fluidization the extent of mixing of particles of different size depends on the riser diameter, gas velocity,

  7. Fluidized bed selective pyrolysis of coal

    Science.gov (United States)

    Shang, J.Y.; Cha, C.Y.; Merriam, N.W.

    1992-12-15

    The present invention discloses a process for the pyrolysis of coal which comprises the effective utilization of two zonal inclined fluidized beds, where said zones can be selectively controlled as to temperature and heating rate. The first zonal inclined fluidized bed serves as a dryer for crushed coal and additionally is controlled to selectively pyrolyze said coal producing substantially carbon dioxide for recycle use. The second zonal inclined fluidized bed further pyrolyses the coal to gaseous, liquid and char products under controlled temperature and heating rate zones designed to economically integrate the product mix. The gas and liquid products are recovered from the gaseous effluent stream while the char which remains can be further treated or utilized in a subsequent process step. 9 figs.

  8. Analysis of circulating fluidized bed combustion technology

    Energy Technology Data Exchange (ETDEWEB)

    Furusawa, Takehiko; Shimizu, Tadaaki; Yang, Guilin

    1987-05-20

    Fluidized bed combustors are commercialized as a technology to combust solid fuels with higher efficiency and lower emission and have functions of both combustion and simultaneous desulfurization and NOx reduction with dense phase fluidized beds but it is not so easy to realize these problems. The technology of circulating fluidized bed coal combustion is expected to offer potential break-through of various problems. But the details are not reported so far. Quantitative analysis of present situations was conducted and future problems were shown with officially available informations. This analysis includes the circulating rate and loading of solids, heat recovery and heat transfer rate as a function of loading of solids, the design of cyclones related to high solid concentration within the combustor, sulfur retention with reduced Ca/S ratio and problems related to NOx reduction to be developed in future. (51 refs, 23 figs, 8 tabs)

  9. Investigaciones actuales del empleo de Allium sativum en medicina

    Directory of Open Access Journals (Sweden)

    Eslhey María Sánchez Dominguez

    2016-02-01

    Full Text Available Desde tiempos ancestrales el ajo Allium sativum ha sido utilizado por sus propiedades medicinales, ampliamente conocidas. Posee múltiples efectos beneficiosos; tales como: antimicrobiano, hipolipidémico, antitrombótico, actividad antitumoral, antihipertensivo, entre otras. Los compuestos sulfurados presentes en el mismo, principalmente alicina y ajoene, constituyen los principios activos responsables de las actividades biológicas referidas. Se realizó una revisión bibliográfica empleando los recursos disponibles en la red Infomed, específicamente Ebsco, PubMed, Hinari y SciELO, a través de los cuales se accedieron a las bases de datos: Medline, Academic Search Premier, Cochrane Database of Systematic Reviews y MedicLatina, para revisar el estado actual de las investigaciones del ajo en medicina. Existen evidencias científicas que avalan su uso, comprobando los efectos antes referidos. En los últimos años predominan artículos que se centran en el estudio de diferentes formulaciones del ajo: extracto añejo, extracto acuoso, aceite, ajo crudo. En algunas de las referencias consultadas se reconocen limitaciones metodológicas en estas investigaciones. Es consenso que las diferentes formulaciones elaboradas a partir el ajo deben utilizarse como tratamiento complementario.

  10. Gas filtration in binary fluidized beds

    Energy Technology Data Exchange (ETDEWEB)

    Rincon, J. (Univ. de Castilla-La Mancha, Ciudad Real (Spain)); Guardiola, J.; Romero, A. (Univ. de Alcala de Henares, Madrid (Spain))

    1992-12-01

    A systematic experimental study of aerosol filtration in a binary fluidized bed of dielectric material is carried out. Measurements of the collection efficiency when such parameters as gas velocity, bed height, collecting mixture, and column diameter are varied over a wide range have been made. Experimental evidence is given to show that charges generated naturally by triboelectrification of the bed dielectric particles can considerably increase the efficiency of such beds. Furthermore, it is demonstrated that a proper choice of the fluidized mixture can significantly improve the performance of such filters.

  11. First report of isolation and antibiotic susceptibility pattern of Raoultella electrica from table eggs in Jaipur, India

    Directory of Open Access Journals (Sweden)

    A.K. Jain

    2018-01-01

    Full Text Available Raoultella electrica, a Gram-negative, non-spore-forming, rod-shaped facultative anaerobe, was identified during a regular investigation of bacterial contamination in table eggs in the winter season. A total of 165 hen's eggs were collected in the winter season from 15 different areas of the city of Jaipur, India. Gram-negative Enterobacteriales were isolated on selective and differential media by the conventional plate method and were further identified by several biochemical tests and 16S rRNA gene sequencing. Commonly prescribed antibiotics for enteric infection were used for antibiotic susceptibility testing. For isolated microorganisms, different resistance patterns were found against the different antibiotics used (p < 0.01. The multiple antibiotic resistance index of bacterial isolates ranged from 0.10 to 0.60. R. electrica strain 1GB/NBRC 109676/KCTC 32430 was isolated for the first time from commercial chicken's eggs.

  12. Quality in research centers; Calidad en centros de investigacion

    Energy Technology Data Exchange (ETDEWEB)

    Colin Orozco, Leticia [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    2000-07-01

    In order to be able to survive and to have successful in the globalized market, all the organizations must make an effort in learning and understanding the language of the international trade, of the standards that govern it and the technical specifications that are handled for the quality assurance of products and services. In this paper the importance that the implementation of standards ISO-9000 in the research centers has, is presented. [Spanish] Para poder sobrevivir y tener exito en el mercado globalizado todas las organizaciones tienen que esforzarse en el aprendizaje y comprension del lenguaje del comercio internacional, de las normas que lo rigen y de las especificaciones tecnicas que se manejan para asegurar la calidad de los productos y servicios. En este articulo se presenta la importancia que tiene la implantacion de las normas ISO-9000 en los centros de investigacion.

  13. Modelling of Devolatilization in Fluidized Bed Combustion

    DEFF Research Database (Denmark)

    Stenseng, Mette; Lin, Weigang; Johnsson, Jan Erik

    1997-01-01

    A mathematical model is developed to describe the devolatilization process in a circulating fluidized bed combustor. The model is a combination of two submodels: single particle devolatilization and fluid dynamics. The single particle model includes the influence of both chemical kinetics and hea...

  14. Fluidized bed electrowinning of copper. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-07-01

    The objectives of the study were to: design and construct a 10,000- amp fluidized bed electrowinning cell for the recovery of copper from acidic sulfate solutions; demonstrate the technical feasibility of continuous particle recirculation from the electrowinning cell with the ultimate goal of continuous particle removal; and measure cell efficiency as a function of operating conditions.

  15. Fluidized-Bed Silane-Decomposition Reactor

    Science.gov (United States)

    Iya, Sridhar K.

    1991-01-01

    Fluidized-bed pyrolysis reactor produces high-purity polycrystalline silicon from silane or halosilane via efficient heterogeneous deposition of silicon on silicon seed particles. Formation of silicon dust via homogeneous decomposition of silane minimized, and deposition of silicon on wall of reactor effectively eliminated. Silicon used to construct solar cells and other semiconductor products.

  16. Bubble Swarm Rise Velocity in Fluidized Beds.

    Czech Academy of Sciences Publication Activity Database

    Punčochář, Miroslav; Růžička, Marek; Šimčík, Miroslav

    2016-01-01

    Roč. 152, OCT 2 (2016), s. 84-94 ISSN 0009-2509 R&D Projects: GA ČR(CZ) GA15-05534S Institutional support: RVO:67985858 Keywords : bubbling fluidized bed * gas-solid * bubble swarm velocity Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 2.895, year: 2016

  17. Fluidization Behavior of Oil-Contaminated Sand.

    Czech Academy of Sciences Publication Activity Database

    Hartman, Miloslav; Trnka, Otakar; Pohořelý, Michael

    2007-01-01

    Roč. 61, 2 (2007) , s. 93-97 ISSN 0366-6352 R&D Projects: GA AV ČR(CZ) IAA4072201 Institutional research plan: CEZ:AV0Z40720504 Keywords : fluidized bed * hydrodynamics * oil pollution Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 0.367, year: 2007

  18. Inter y transdisciplinariedad en investigaciones ambientales. Una sinopsis

    Directory of Open Access Journals (Sweden)

    Alberto Ramírez-González

    2016-07-01

    Full Text Available El presente artículo de revisión tiene como pretensión realizar un acercamiento al estado actual de conocimiento en torno a la conformación de grupos de investigación y el análisis de la problemática ambiental, bajo enfoques inter y transdisciplinares. Constituye, esencialmente, una investigación teórica soportada en artículos científicos, libros y documentos publicados por entidades y organizaciones reconocidas nacional o internacionalmente. El documento incluye diversos puntos de vista en torno a los marcos conceptuales, teóricos y metodológicos, y expone algunas problemáticas ambientales y sociales que se presume deben ser abordadas desde tales enfoques. Adicionalmente, presenta algunos de los intersticios que ligan lo ambiental con algunas ciencias y disciplinas. La revisión hace acopio de los principales avances y los retos más recurrentes en torno a la formación de profesionales que cumplan con las competencias más pertinentes y adecuadas para la implementación inter y transdisciplinar. Adicionalmente, enuncia algunos de los factores asociados con el éxito y el fracaso de los investigadores, los grupos de investigación y las investigaciones, que han pretendido tales enfoques. Finalmente, expone algunas recomendaciones que podrían potenciar el desempeño de los grupos que realizan investigaciones inter y transdisciplinares, las cuales han emergido, precisamente, del seguimiento a proyectos de esta naturaleza. CC BY-NC-SA Gestión y Ambiente (2016.

  19. Management and control of the electrical energy demand; Administracion y control de la demanda de la energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Johnson Controls [Comision Federal de Electricidad (Mexico)

    2005-07-01

    Administrative measures allow a reduction in the energy consumption, but not always in the electrical demand. Control measures allow a reduction in the billing of the electrical demand, but not always in the energy consumption. This is why it is explained in this document what management and control of the electrical demand is, as well as its control strategies, the control alternatives, the billing demand and at the same time graphical representations along with three practical cases on the management of demand in air compressors, air conditioning equipment and in corporative buildings are presented. [Spanish] La aplicacion de las medidas administrativas permite reducir el consumo de energia, pero no siempre la demanda electrica. La aplicacion de medidas de control permiten reducir la demanda electrica facturable, pero no siempre el consumo de energia. Es por eso que en este documento se explica que es la administracion y el control de la demanda electrica, sus estrategias de control, las alternativas de control, la demanda facturable, representaciones graficas y tres casos practicos sobre la administracion de demanda en compresores de aire, la administracion de demanda en aire acondicionado y la administracion de demanda en un edificio corporativo.

  20. Modeling biomass gasification in circulating fluidized beds

    Science.gov (United States)

    Miao, Qi

    In this thesis, the modeling of biomass gasification in circulating fluidized beds was studied. The hydrodynamics of a circulating fluidized bed operating on biomass particles were first investigated, both experimentally and numerically. Then a comprehensive mathematical model was presented to predict the overall performance of a 1.2 MWe biomass gasification and power generation plant. A sensitivity analysis was conducted to test its response to several gasifier operating conditions. The model was validated using the experimental results obtained from the plant and two other circulating fluidized bed biomass gasifiers (CFBBGs). Finally, an ASPEN PLUS simulation model of biomass gasification was presented based on minimization of the Gibbs free energy of the reaction system at chemical equilibrium. Hydrodynamics plays a crucial role in defining the performance of gas-solid circulating fluidized beds (CFBs). A 2-dimensional mathematical model was developed considering the hydrodynamic behavior of CFB gasifiers. In the modeling, the CFB riser was divided into two regions: a dense region at the bottom and a dilute region at the top of the riser. Kunii and Levenspiel (1991)'s model was adopted to express the vertical solids distribution with some other assumptions. Radial distributions of bed voidage were taken into account in the upper zone by using Zhang et al. (1991)'s correlation. For model validation purposes, a cold model CFB was employed, in which sawdust was transported with air as the fluidizing agent. A comprehensive mathematical model was developed to predict the overall performance of a 1.2 MWe biomass gasification and power generation demonstration plant in China. Hydrodynamics as well as chemical reaction kinetics were considered. The fluidized bed riser was divided into two distinct sections: (a) a dense region at the bottom of the bed where biomass undergoes mainly heterogeneous reactions and (b) a dilute region at the top where most of homogeneous

  1. 21 CFR 890.5160 - Air-fluidized bed.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Air-fluidized bed. 890.5160 Section 890.5160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5160 Air-fluidized bed. (a) Identification. An air-fluidized bed is a...

  2. Update on status of fluidized-bed combustion technology

    International Nuclear Information System (INIS)

    Stallings, J.; Boyd, T.; Brown, R.

    1992-01-01

    During the 1980s, fluidized-bed combustion technology has become the dominant technology for solid-fuel-fired power generation systems in the United States. Atmospheric fluidized beds as large as 160 MWe in capacity are now in operation, while pressurized systems reaching 80 MWe have started up in the last year. The commercial status, boiler performance, emissions, and future developments for both atmospheric and pressurized fluidized-bed combustion systems are discussed

  3. Fuzzy control for the operation of an electrical energy generation system based on standard fuel cells PEM; Control difuso para la operacion de un sistema de generacion de energia electrica basado en celdas de combustible tipo PEM

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez R, Miguel; Gutierrez A, Ruben [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Rodriguez P, Alejandro [Centro Nacional de Investigacion y Desarrollo Tecnologico (Cenidet), Cuernavaca, Morelos (Mexico)

    2005-07-01

    Fuel cells, as totally clean power plants, have many applications in the industry in general, in the transport system, in the electricity generation for domestic consumption and in the communication systems, among others. When developing new forms of generation with renewable energy sources, it must be considered that petroleum will stop in being an available power resource. The interest in the study of the fuel cells has been increased in the last years because it is considered a solution to the supply of distributed energy problem. Therefore, already exist research institutions that are developing work on this technology. A generation of electrical energy system based on fuel cells is a nonlinear system where the control of the variables of the process, such as the temperature of the system and the pressurization of the reactants, are an important aspect for its proper operation, since it influences in the water balance and therefore in the global efficiency of the system. [Spanish] Las celdas de combustible, como fuente de energia totalmente limpia, tienen muchas aplicaciones en la industria en general: en el sistema de transporte, en la generacion de electricidad para consumo domestico y en los sistemas de comunicacion, entre otros. Al desarrollar nuevas formas de generacion con fuentes de energia renovables, se debe considerar que el petroleo dejara de ser un recurso energetico disponible. El interes en el estudio de las celdas de combustible se ha incrementado en los ultimos anos debido a que se le considera una solucion al problema de abasto de energia distribuida. Por lo tanto, ya existen instituciones de investigacion que estan desarrollando trabajos sobre esta tecnologia. Un sistema de generacion de energia electrica basado en celdas de combustible es un sistema no lineal en donde el control de las variables del proceso, tales como la temperatura del sistema y la presurizacion de los reactantes, es un aspecto importante para su buen funcionamiento, ya que

  4. FUNDAMENTOS AXIOLÓGICOS EN LAS INVESTIGACIONES EDUCACIONALES

    Directory of Open Access Journals (Sweden)

    Mayra Acebo Rivera

    2016-04-01

    Full Text Available El trabajo se centra en la importancia que tiene el conocimiento de la axiología para los docentes e investigadores, del área de las Ciencias Pedagógicas. Se ofrecen fundamentos relacionados con la conceptualización de las categorías, educación en valores y formación de valores y la propuesta de su definición desde una concepción de identidad. Se presentan los resultados de la indagación de la problemática desde un proyecto de investigación de formación de valores en la Universidad de Las Tunas. El estudio realizado demuestra que en el centro de la preocupación de los investigadores del área educativa, se encuentra la formación de valores, no obstante se reconocen algunas insuficiencias en los fundamentos axiológicos que sustentan estas investigaciones que indican la necesidad de diseñar acciones para profundizar en la fundamentación de las tesis doctorales.

  5. Raoultella electrica sp. nov., isolated from anodic biofilms of a glucose-fed microbial fuel cell.

    Science.gov (United States)

    Kimura, Zen-ichiro; Chung, Kyung Mi; Itoh, Hiroaki; Hiraishi, Akira; Okabe, Satoshi

    2014-04-01

    A Gram-stain-negative, non-spore-forming, rod-shaped bacterium, designated strain 1GB(T), was isolated from anodic biofilms of a glucose-fed microbial fuel cell. Strain 1GB(T) was facultatively anaerobic and chemo-organotrophic, having both a respiratory and a fermentative type of metabolism, and utilized a wide variety of sugars as carbon and energy sources. Cells grown aerobically contained Q-8 as the major quinone, but excreted Q-9 and a small amount of Q-10 when cultured with an electrode serving as the sole electron acceptor. The G+C content of the genomic DNA of 1GB(T) was 54.5 mol%. Multilocus sequence typing (MLST) analysis showed that strain 1GB(T) represented a distinct lineage within the genus Raoultella (98.5-99.4 % 16S rRNA gene sequence similarity and 94.0-96.5 % sequence similarity based on the three concatenated housekeeping genes gyrA, rpoB and parC. Strain 1GB(T) exhibited DNA-DNA hybridization relatedness of 7-43 % with type strains of all established species of the genus Raoultella. On the basis of these phenotypic, phylogenetic and genotypic data, the name Raoultella electrica sp. nov. is proposed for strain 1GB(T). The type strain is 1GB(T) ( = NBRC 109676(T) = KCTC 32430(T)).

  6. Electric protections based in microprocessors in power plants; Protecciones electricas basadas en microprocesadores en centrales generadoras

    Energy Technology Data Exchange (ETDEWEB)

    Libreros, Domitilo; Castanon Jimenez, Jose Ismael [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    This article is centered around the substitution of the conventional electric protections of a power plant in connection type unit for protections based in microprocessors. A general model of conventional protection of a power plant is described and the number of analogic and digital signals that intervene in that model are quantified. A model is setup for power plant protection with microprocessors, analyzing each one of the modules that would form it. Finally, the algorithms to carry on such protection are presented. [Espanol] Este articulo se centra en torno a la sustitucion de las protecciones electricas convencionales de una central generadora en conexion tipo unidad por protecciones basadas en microprocesadores. Se describe el modelo general de proteccion convencional de una central generadora y se cuantifica el numero de senales analogicas y digitales que interviene en dicho modelo. Se propone un modelo para proteccion de centrales generadoras mediante microprocesadores, analizandose cada uno de los modulos que lo conformarian. Finalmente, se presentan los algoritmos para realizar dicha proteccion.

  7. Wind energy for electricity generation; Generacion electrica con energia del viento

    Energy Technology Data Exchange (ETDEWEB)

    Huacuz Villamar, Jorge M.; Borja Diaz, Marco Antonio R. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-09-01

    A description is made of electricity generation utilizing wind energy (Eoloelectric Generation). The case of Mexico is reviewed in respect to this technology, mentioning a small power plant of 1.5 Megawatts installed by the Comision Federal de Electricidad in the zone of La Ventosa in the State of Oaxaca. Mention is made of the possible causes why Mexico has not advanced in this type of power plants for power generation as in other countries like Germany, Spain and India. The advance in these countries is shown as well as the growth statistics of the wind power in the world. It is concluded that there is not in Mexico a strategy for wind energy utilization for electricity generation in spite of the potential benefits this technology offers [Espanol] Se describe el caso de la generacion electrica utilizando la energia del viento (Generacion Eoloelectrica). Se aborda el caso de Mexico respecto a esta tecnologia, mencionando una pequena central de 1.5 Megawatts (MW) instalada por la Comision Federal de Electricidad (CFE) en la zona de la Ventosa, Oaxaca. Se mencionan las posibles causas por las que en Mexico este tipo de centrales de generacion de energia no ha avanzado como en otros paises, por ejemplo: Alemania, Espana y la India. Se muestran los avances de estos paises, asi como una estadistica del crecimiento de la generacion eoloelectrica en el mundo. Se concluye en que no existe en Mexico una estrategia para la generacion eoloelectrica a pesar de los beneficios potenciales que ofrece esta tecnologia

  8. NUCLA Circulating Atmospheric Fluidized Bed Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    1992-02-01

    The objective of this DOE Cooperative Agreement is to conduct a cost-shared clean coal technology project to demonstrate the feasibility of circulating fluidized bed combustion technology and to evaluate economic, environmental, and operational benefits of CFB steam generators on a utility scale. At the conclusion of the Phase 2 program, testing related to satisfying these objectives was completed. Data analysis and reporting are scheduled for completion by October 1991. (VC)

  9. Circulating fluidized bed boilers design and operations

    CERN Document Server

    Basu, Prabir

    1991-01-01

    This book provides practicing engineers and students with insight into the design and operation of circulating fluidized bed (CFB) boilers. Through a combination of theoretical concepts and practical experience, this book gives the reader a basic understanding of the many aspects of this subject.Important environmental considerations, including solid waste disposal and predicted emissions, are addressed individually in separate chapters. This book places an emphasis on combustion, hydrodynamics, heat transfer, and material issues, and illustrates these concepts with numerous examples of pres

  10. Gas distributor for fluidized bed coal gasifier

    Science.gov (United States)

    Worley, Arthur C.; Zboray, James A.

    1980-01-01

    A gas distributor for distributing high temperature reaction gases to a fluidized bed of coal particles in a coal gasification process. The distributor includes a pipe with a refractory reinforced lining and a plurality of openings in the lining through which gas is fed into the bed. These feed openings have an expanding tapered shape in the downstream or exhaust direction which aids in reducing the velocity of the gas jets as they enter the bed.

  11. Reinforcement versus fluidization in cytoskeletal mechanoresponsiveness.

    Directory of Open Access Journals (Sweden)

    Ramaswamy Krishnan

    Full Text Available Every adherent eukaryotic cell exerts appreciable traction forces upon its substrate. Moreover, every resident cell within the heart, great vessels, bladder, gut or lung routinely experiences large periodic stretches. As an acute response to such stretches the cytoskeleton can stiffen, increase traction forces and reinforce, as reported by some, or can soften and fluidize, as reported more recently by our laboratory, but in any given circumstance it remains unknown which response might prevail or why. Using a novel nanotechnology, we show here that in loading conditions expected in most physiological circumstances the localized reinforcement response fails to scale up to the level of homogeneous cell stretch; fluidization trumps reinforcement. Whereas the reinforcement response is known to be mediated by upstream mechanosensing and downstream signaling, results presented here show the fluidization response to be altogether novel: it is a direct physical effect of mechanical force acting upon a structural lattice that is soft and fragile. Cytoskeletal softness and fragility, we argue, is consistent with early evolutionary adaptations of the eukaryotic cell to material properties of a soft inert microenvironment.

  12. Pressurized Fluidized Bed Combustion of Sewage Sludge

    Science.gov (United States)

    Suzuki, Yoshizo; Nojima, Tomoyuki; Kakuta, Akihiko; Moritomi, Hiroshi

    A conceptual design of an energy recovering system from sewage sludge was proposed. This system consists of a pressurized fluidized bed combustor, a gas turbine, and a heat exchanger for preheating of combustion air. Thermal efficiency was estimated roughly as 10-25%. In order to know the combustion characteristics of the sewage sludge under the elevated pressure condition, combustion tests of the dry and wet sewage sludge were carried out by using laboratory scale pressurized fluidized bed combustors. Combustibility of the sewage sludge was good enough and almost complete combustion was achieved in the combustion of the actual wet sludge. CO emission and NOx emission were marvelously low especially during the combustion of wet sewage sludge regardless of high volatile and nitrogen content of the sewage sludge. However, nitrous oxide (N2O) emission was very high. Hence, almost all nitrogen oxides were emitted as the form of N2O. From these combustion tests, we judged combustion of the sewage sludge with the pressurized fluidized bed combustor is suitable, and the conceptual design of the power generation system is available.

  13. Status of the fluidized bed unit

    International Nuclear Information System (INIS)

    Williams, P.M.; Wade, J.F.

    1994-01-01

    Rocky Flats has a serious mixed waste problem. No technology or company has a license and available facilities to remedy this dilemma. One solution under study is to use a catalytic fluidized bed unit to destroy the combustible portion of the mixed waste. The fluidized bed thermal treatment program at Rocky Flats is building on knowledge gained over twenty years of successful development activity. The FBU has numerous technical advantages over other thermal technologies to treat Rocky Flats' mixed waste, the largest being the lower temperature (700 degrees C versus 1000 degrees C) which reduces acid corrosion and mechanical failures and obviates the need for ceramic lining. Successful demonstrations have taken place on bench, pilot, and full-scale tests using radioactive mixed wastes. The program is approaching implementation and licensing of a production-scale fluidized bed system for the safe treatment of mixed waste. The measure for success on this project is the ability to work closely with the community to jointly solve problems and respond to concerns of mixed waste treatment at Rocky Flats

  14. Pulsed atmospheric fluidized-bed combustor development

    International Nuclear Information System (INIS)

    1992-05-01

    Pulsed atmospheric fluidized-bed combustion (PAFBC) is a unique and innovative coal-fueled technology that has the potential to meet these conditions and provide heat and/or process steam to small industrial, commercial, institutional and residential complexes. The potential of Pulse Atmospheric Fluidized Bed Combustion (PAFBC) technology has been amply demonstrated under the sponsorship of a previous DOE/METC contract (DE-AC21-88MC25069). The environmental performance of a coal-fired laboratory-scale system (1.5 million British Thermal Units per hour) (MMBtu/hr) significantly surpassed that of conventional bubbling and circulating fluidized-bed combustion units (see Table 1 for performance comparison). Prompted by these encouraging results in combustion, sulfur capture, emissions control, and enhanced heat transfer, Island Creek Coal Company (ICC) and Baltimore Thermal Energy Corporation expressed interest in the technology and offered to participate by providing host sites for field testing. EA's have been submitted independently for each of these field test sites. This submission addresses the preliminary testing of the PAFBC unit at Manufacturing and Technology Conversion International's (MTCI) Baltimore, MD facility

  15. Method for fluidizing and coating ultrafine particles, device for fluidizing and coating ultrafine particles

    Science.gov (United States)

    Li, Jie; Liu, Yung Y

    2015-01-20

    The invention provides a method for dispersing particles within a reaction field, the method comprising confining the particles to the reaction field using a standing wave. The invention also provides a system for coating particles, the system comprising a reaction zone; a means for producing fluidized particles within the reaction zone; a fluid to produce a standing wave within the reaction zone; and a means for introducing coating moieties to the reaction zone. The invention also provides a method for coating particles, the method comprising fluidizing the particles, subjecting the particles to a standing wave; and contacting the subjected particles with a coating moiety.

  16. Fluidized Bed Asbestos Sampler Design and Testing

    Energy Technology Data Exchange (ETDEWEB)

    Karen E. Wright; Barry H. O' Brien

    2007-12-01

    A large number of samples are required to characterize a site contaminated with asbestos from previous mine or other industrial operations. Current methods, such as EPA Region 10’s glovebox method, or the Berman Elutriator method are time consuming and costly primarily because the equipment is difficult to decontaminate between samples. EPA desires a shorter and less costly method for characterizing soil samples for asbestos. The objective of this was to design and test a qualitative asbestos sampler that operates as a fluidized bed. The proposed sampler employs a conical spouted bed to vigorously mix the soil and separate fine particulate including asbestos fibers on filters. The filters are then analyzed using transmission electron microscopy for presence of asbestos. During initial testing of a glass prototype using ASTM 20/30 sand and clay fines as asbestos surrogates, fine particulate adhered to the sides of the glass vessel and the tubing to the collection filter – presumably due to static charge on the fine particulate. This limited the fines recovery to ~5% of the amount added to the sand surrogate. A second prototype was constructed of stainless steel, which improved fines recovery to about 10%. Fines recovery was increased to 15% by either humidifying the inlet air or introducing a voltage probe in the air space above the sample. Since this was not a substantial improvement, testing using the steel prototype proceeded without using these techniques. Final testing of the second prototype using asbestos suggests that the fluidized bed is considerably more sensitive than the Berman elutriator method. Using a sand/tremolite mixture with 0.005% tremolite, the Berman elutriator did not segregate any asbestos structures while the fluidized bed segregated an average of 11.7. The fluidized bed was also able to segregate structures in samples containing asbestos at a 0.0001% concentration, while the Berman elutriator method did not detect any fibers at this

  17. RESISTENCIAS FEMENINAS: INVESTIGACIONES ENTRE EL CUERPO Y EL HABLA

    Directory of Open Access Journals (Sweden)

    Thais Oliveira Brandão

    2015-06-01

    Full Text Available Presentamos una propuesta de análisis de lo femenino dentro de algunos conceptos clave de la teoría feminista como son: el género, el sexo y la sexualidad, desde una postura implicada con investigaciones comprometidas, situadas y encarnadas. Analizaremos posibilidades de investigar los lenguajes orales y corporales de las mujeres con el fi n de encontrar la materialidad del cuerpo/habla en una relación sujeto/sujeto en investigación. Resaltamos que estas expresiones (orales y corporales son vividas como una forma de resistencia, de creación y que, por eso mismo, reclaman libertad. El cuerpo y el habla femeninos, interdependientes, se expresan con estrategias propias y constituyen un espacio común de liberación que también está disponible para ser investigado. AbstractAn approach on analyzing some key concepts of feminism theory, such as: gender, sex and sexuality which involves a committed thought with the compromised, embodied and located research we show in this paper. We will analyze the possibilities of looking for female oral and body languages in order to fi nd the materiality of the body/speech in relation with subject/subject in research. We emphasize that these expressions (oral and body languages are lived as a resistance and are constructed. That is why they demand freedom. The female’s body and speech are independent and are expressed with their own strategies and space of freedom which is able to be researched.

  18. Artificial Neural Network Modeling of an Inverse Fluidized Bed ...

    African Journals Online (AJOL)

    The application of neural networks to model a laboratory scale inverse fluidized bed reactor has been studied. A Radial Basis Function neural network has been successfully employed for the modeling of the inverse fluidized bed reactor. In the proposed model, the trained neural network represents the kinetics of biological ...

  19. Propylene polymerization in a circulating slugging fluidized bed reactor

    NARCIS (Netherlands)

    van Putten, I.C.

    2004-01-01

    The work presented in this thesis is concerned with research on the riser of a circulating fluidized bed system for olefin polymerization. In the riser section, fluidization takes place in the transporting slugging mode and polymer particles are produced in the riser in a non-isothermal way.

  20. Heat exchanger support apparatus in a fluidized bed

    Science.gov (United States)

    Lawton, Carl W.

    1982-01-01

    A heat exchanger is mounted in the upper portion of a fluidized combusting bed for the control of the temperature of the bed. A support, made up of tubes, is extended from the perforated plate of the fluidized bed up to the heat exchanger. The tubular support framework for the heat exchanger has liquid circulated therethrough to prevent deterioration of the support.

  1. Air Distributor Designs for Fluidized Bed Combustors: A Review

    Directory of Open Access Journals (Sweden)

    A. Shukrie

    2016-06-01

    Full Text Available Fluidized bed combustion (FBC has been recognized as one of the suitable technologies for converting a wide variety of biomass fuels into energy. One of the key factors affecting the successful operation of fluidized bed combustion is its distributor plate design. Therefore, the main purpose of this article is to provide a critical overview of the published studies that are relevant to the characteristics of different fluidized bed air distributor designs. The review of available works display that the type of distributor design significantly affects the operation of the fluidized bed i.e., performance characteristics, fluidization quality, air flow dynamics, solid pattern and mixing caused by the direction of air flow through the distributors. Overall it is observed that high pressure drop across the distributor is one of the major draw backs of the current distributor designs. However, fluidization was stable in a fluidized bed operated at a low perforation ratio distributor due to the pressure drop across the distributor, adequate to provide uniform gas distribution. The swirling motion produced by the inclined injection of gas promotes lateral dispersion and significantly improves fluidization quality. Lastly, the research gaps are highlighted for future improvement consideration on the development of efficient distributor designs.

  2. Hydrodynamic studies in designing of fluidized bed system

    International Nuclear Information System (INIS)

    Mohamad Puad Abu; Muhd Noor Muhd Yunus; Syed Nasaruddin Syed Idris

    2002-01-01

    Fluidized bed process have been used mostly in the petroleum and paper industries, and for processing nuclear wastes, spent cook liquor, wood chips, and sewage sludge disposal. Even at MINT some of the equipment available used this principal. Before we use or purchase this equipment, it is very grateful if we could understand how the system has been designed. The hydrodynamic fluidization studies is very important in designing of fluidized bed system especially in determining the minimum fluidizing velocity, terminal velocity, flexibility of operation, slugging condition, bubble size and velocity, and transport disengaging height. They can be determined either by calculation or experimentation. This paper will highlight the hydrodynamic study that need to be performed in designing of fluidized bed system so that its can be used appropriately. (Author)

  3. Electric power conservation while using pumping systems; Conservacion de Energia Electrica en Sistemas de Bombeo

    Energy Technology Data Exchange (ETDEWEB)

    Nambiar, P

    2007-01-15

    The pumping systems provide about 20 to 25 percent of energy which is necessary worldwide: it is fruitful to understand how to use electric power efficiently, to achieve the reduction regarding expenses a pumping system implies.It is essential to possess a better knowledge about the pumping system and its applications, in order to be able to use energy responsibly. If people do not how to operate this kind of systems properly, they will use inadequate equipment that will cause an energy waste. In addition it is important to know: alternative methods to meet variable demands, an adapted system to pump water requirements in order to ensure the pump work in its pumping point, and the life cycle system cost for the energy saving in the long term. [Spanish] En promedio del 20 al 25% de la energia necesaria en el mundo proviene de los sistemas de bombeo, por tal razon es importante saber como utilizar la energia electrica con eficiencia para asi lograr reducir los gastos que este tipo de sistemas implican. Para poder hacer un buen uso de la energia, es necesario que se tenga un conocimiento mayor del sistema de bombeo y aplicacion, ya que la ignorancia sobre esto exige el uso de aparatos que contribuyen al desperdicio de la energia; por otro lado tambien es esencial conocer metodos alternos para demandas variables, tener un sistema que se adapte a las necesidades de bombeo del agua para asegurarse de que cada bomba trabaje cerca de su punto de bombeo y finalmente conocer el costo del ciclo de vida del sistema para el ahorro de energia a largo plazo.

  4. Natural ionizing system to electrical protection and energy; Sistema ionizante natural de proteccion electrica y energias

    Energy Technology Data Exchange (ETDEWEB)

    Cabareda Fermin; Luis [Universidad de Los Andes (Venezuela)]. E-mail: lcabaredaf@gmail.com

    2013-03-15

    This is the new highest technology, 100% Venezuelan and unique in the world, technological innovation, world patent for maximum protection, security and zero risk (0) to all electrical and power generation systems: hydroelectric and thermoelectric power plants, wind, nuclear and solar power plants, etc; it's the only technology around the world that has the potential to disperse and propagate to land mass the enormous energies associated to the atmospheric discharges (lightning), which are in the order: 200,000 to 500,000 Amperes; 1,000 million Kilowatts and high-level transient voltage of 100 million Volts. This new high technology is the solution to the paradigm of Benjamin Franklin and it is the mechanism to end blackouts that produce so many damages and losses of billions of dollars to both generators and users of electrical service, throughout the world. [Spanish] Esta nueva mas alta tecnologia, 100% venezolana y unica en el mundo, innovacion tecnologica, patente mundial ofrece maxima proteccion, seguridad y riesgo cero (0) a todos los sistemas de generacion electrica: centrales hidroelectricas, termoelectricas, de viento, nucleares y solar, otros; es la unica tecnologia en el mundo que tiene el potencial para dispersar y propagar a la masa terrestre las enormes energias asociadas a las descargas atmosfericas (rayos) que estan en el orden de: 200.000 a 500.000 amperios, 1.000 millones de kilovatios y voltajes transitorios de alto nivel de 100 millones de voltios. Esta nueva alta tecnologia es la solucion al paradigma de Benjamin Franklin y es el mecanismo para eliminar apagones que producen danos y perdidas de billones de dolares para ambos: generados y usuarios del servicio electrico, alrededor del mundo.

  5. Archimedes' principle in fluidized granular systems.

    Science.gov (United States)

    Huerta, D A; Sosa, Victor; Vargas, M C; Ruiz-Suárez, J C

    2005-09-01

    We fluidize a granular bed in a rectangular container by injecting energy through the lateral walls with high-frequency sinusoidal horizontal vibrations. In this way, the bed is brought to a steady state with no convection. We measured buoyancy forces on light spheres immersed in the bed and found that they obey Archimedes' principle. The buoyancy forces decrease when we reduce the injected energy. By measuring ascension velocities as a function of gamma, we can evaluate the frictional drag of the bed; its exponential dependence agrees very well with previous findings. Rising times of the intruders ascending through the bed were also measured, they increase monotonically as we increase the density.

  6. Fluidized bed adsorption of cephalosporin C.

    Science.gov (United States)

    Hicketier, M; Buchholz, K

    2002-02-28

    Fluidized bed adsorption can substantially simplify the recovery of products from fermentation. There are, however, several critical parameters, which have a significant influence on the performance of such systems. This paper presents experimental results on the adsorption of an antibiotic, Cephalosporin C, on macroporous adsorbents of the polystyrene type and on an ion exchanger. Internals (static mixers) were used to control bed expansion and mixing, the range of flow rates could thus be extended significantly. An integrated mathematical model was developed comprising bed expansion, residence time distribution and mixing, adsorption kinetics and equilibria.

  7. Nucla circulating atmospheric fluidized bed demonstration project

    Energy Technology Data Exchange (ETDEWEB)

    1991-01-31

    During the fourth quarter of 1990, steady-state performance testing at the Nucla Circulating Fluidized Bed (CFB) resumed under sponsorship of the US Department of Energy. Co-sponsorship of the Demonstration Test Program by the Electric Power Research Institute (EPRI) was completed on June 15, 1990. From October through December, 1990, Colorado-Ute Electric Association (CUEA) completed a total of 23 steady-state performance tests, 4 dynamic tests, and set operating records during November and December as the result of improved unit operating reliability. Highlight events and achievements during this period of operation are presented.

  8. Electrostatic collection efficiency in binary fluidized beds

    Energy Technology Data Exchange (ETDEWEB)

    Romero, A.; Guardiola, J.; Rincon, J. (Univ. of Alcala de Henares, Madrid (Spain))

    1992-01-01

    Fluidized beds of binary mixtures have been used to clean air streams containing dust particles in the size range 4.4 to 14 {mu}m. All beds were composed of glass beads and plastic granules mixed at different proportions. The effect on the electrostatic collection efficiency of a number of variables, including type of collecting mixture, bed height, and gas velocity, was examined. To calculate the single collection efficiency from experimental results, an early model proposed by Clift et al. was used. The electrostatic collection efficiency was determined by subtracting the other individual mechanism efficiencies from the single particle collection efficiency.

  9. Pyrolysis reactor and fluidized bed combustion chamber

    Science.gov (United States)

    Green, Norman W.

    1981-01-06

    A solid carbonaceous material is pyrolyzed in a descending flow pyrolysis reactor in the presence of a particulate source of heat to yield a particulate carbon containing solid residue. The particulate source of heat is obtained by educting with a gaseous source of oxygen the particulate carbon containing solid residue from a fluidized bed into a first combustion zone coupled to a second combustion zone. A source of oxygen is introduced into the second combustion zone to oxidize carbon monoxide formed in the first combustion zone to heat the solid residue to the temperature of the particulate source of heat.

  10. Control voltage of the generator of auto-excited induction for applications on micro/mini generation o electric power; Control de voltaje del generador de induccion auto-excitado para aplicaciones de micro/mini generacion de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Torres Montalvo, Emmanuel

    2006-09-15

    literature, since in this one it is only mentioned that the dynamics of the voltage and frequency change, but it is not shown how. In base of the dynamic behavior of the GIAE a scheme of simple control is proposed to regulate the generator voltage with the minimum of necessary elements, which is translated into a reduced cost, greater reliability and in addition provides a satisfactory voltage regulation. The control strategy is simple but functional, which permits its implementation without major complications. Finally an analysis is realized of the harmonic distortion produced by the proposed control. [Spanish] Aunque solamente una parte de la potencia mini/micro hidraulica ha sido explorada en nuestro pais, este tipo de generacion de energia electrica puede ser considerada como una forma viable de generacion de electricidad, principalmente por lo que respecta a los aspectos ecologicos, economicos y sociales. El impacto que pueden tener estas plantas en las regiones en las que son instaladas es siempre positivo: reduccion de costo de la energia, derrama economica, y principalmente un bienestar social. La energia electrica es uno de los pilares para el desarrollo economico de un pais y proporciona una mejor calidad de vida. En la actualidad la investigacion y la tecnologia orientada a la operacion y control de las micro/mini plantas de generacion ha despertado el interes de muchos investigadores en diversos paises del mundo como China, la India, Canada, USA, por mencionar algunos. El generador de induccion juega un papel crucial en la utilizacion de estas tecnologias. El trabajo de Basset y Potter en 1935, es la piedra angular sobre la posibilidad de generar energia haciendo uso de la maquina de induccion y un banco de capacitores conectado a las terminales de la maquina. Esta configuracion se conoce como generador de induccion auto-excitado (GIAE). Se han realizado diversas investigaciones que tratan sobre el principio de funcionamiento y el comportamiento dinamico de un

  11. Fluidized bed combustion: mixing and pollutant limitation

    Energy Technology Data Exchange (ETDEWEB)

    Leckner, B. [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Energy Conversion

    1997-10-01

    Fluidized bed combustion (FBC) has been applied commercially during a few decades, and sufficient knowledge is gained to design boilers with sizes of up to several hundreds of megawatt thermal power (MW{sub th}). The knowledge of what goes on inside a large combustion chamber is still limited, however, and this impedes further optimization and efficient solution of problems that might occur. Despite this lack of knowledge the present survey deals with combustion chamber processes and discusses mixing and distribution of fuel and air in the combustion chamber and its importance for sulphur capture and reduction of emissions of nitrogen oxides. It is desirable to present the material in a general way and to cover the entire field of FBC. However, the scarce openly published information deals mostly with coal combustion in atmospheric circulating fluidized bed (CFB) combustors, and therefore this application will receive most attention, but reference is also made to pressurized combustion and to other fuels than coal. In this context the important work made in the LIEKKI project on the analysis of different fuels and on the influence of pressure should be especially pointed out. (orig.)

  12. Next generation fluidized bed granulator automation.

    Science.gov (United States)

    Rantanen, J; Känsäkoski, M; Suhonen, J; Tenhunen, J; Lehtonen, S; Rajalahti, T; Mannermaa, J P; Yliruusi, J

    2000-05-06

    A system for fluidized bed granulator automation with in-line multichannel near infrared (NIR) moisture measurement and a unique air flow rate measurement design was assembled, and the information gained was investigated. The multivariate process data collected was analyzed using principal component analysis (PCA). The test materials (theophylline and microcrystalline cellulose) were granulated and the calibration behavior of the multichannel NIR set-up was evaluated against full Fourier Transform (FT) NIR spectra. Accurate and reliable process air flow rate measurement proved critical in controlling the granulation process. The process data describing the state of the process was projected in two dimensions, and the information from various trend charts was outlined simultaneously. The absorbence of test material at correction wavelengths (NIR region) and the nature of material-water interactions affected the detected in-line NIR water signal. This resulted in different calibration models for the test materials. Development of process analytical methods together with new data visualization algorithms creates new tools for in-process control of the fluidized bed granulation.

  13. Fluidized bed gasification of select granular biomaterials.

    Science.gov (United States)

    Subramanian, P; Sampathrajan, A; Venkatachalam, P

    2011-01-01

    Biomaterials can be converted into solid, liquid and gaseous fuels through thermochemical or biochemical conversion processes. Thermochemical conversion of granular biomaterials is difficult because of its physical nature and one of the suitable processes is fluidized bed gasification. In this study, coir pith, rice husk and saw dust were selected and synthetic gas was generated using a fluidized bed gasifier. Gas compositions of product gas were analyzed and the percentage of carbon monoxide and carbon dioxide was in the range of 8.24-19.55 and 10.21-17.14, respectively. The effect of equivalence ratio (0.3, 0.4 and 0.5) and reaction time (at 10 min interval) on gas constituents was studied. The gas yield for coir pith, rice husk and sawdust were found to be in the range of 1.98-3.24, 1.79-2.81 and 2.18-3.70 Nm3 kg(-1), respectively. Models were developed to study the influence of biomaterial properties and operating conditions on molar concentration of gas constituents and energy output. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. Rocky Flats Plant fluidized-bed incinerator

    International Nuclear Information System (INIS)

    Meile, L.J.; Meyer, F.G.; Johnson, A.J.; Ziegler, D.L.

    1982-01-01

    Laboratory and pilot-scale testing of a fluidized-bed incineration process for radioactive wastes led to the installation of an 82-kg/hr demonstration unit at Rocky Flats Plant in 1978. Design philosophy and criteria were formulated to fulfill the needs and objectives of an improved radwaste-incineration system. Unique process concepts include low-temperature (550 0 C), flameless, fluidized-bed combustion and catalytic afterburning; in-situ neutralization of acid gases; and dry off-gas cleanup. Detailed descriptions of the process and equipment are presented along with a summary of the equipment and process performance during a 2-1/2 year operational-testing period. Equipment modifications made during the test period are described. Operating personnel requirements for solid-waste burning are shown to be greater than those required for liquid-waste incineration; differences are discussed. Process-utility and raw-materials consumption rates for full-capacity operation are presented and explained. Improvements in equipment and operating procedures are recommended for any future installations. Process flow diagrams, an area floor plan, a process-control-system schematic, and equipment sketches are included

  15. Parameters critical to the morphology of fluidization craters

    Science.gov (United States)

    Siegal, B. S.; Gold, D. P.

    1973-01-01

    In order to study further the role of fluidization on the moon, a laboratory investigation was undertaken on two particulate material size fractions to determine the effect of variables, such as, duration of gas streaming, gas pressure, and 'regolith' thickness on the morphology of fluidization craters. A 3.175-mm cylindrical vent was used to simulate a gas streaming conduit. Details of the fluidization chamber are discussed together with questions of experimental control, aspects of nomenclature, crater measurements, and the effect of variables.

  16. Ash behavior and de-fluidization in low temperature circulating fluidized bed biomass gasifier

    DEFF Research Database (Denmark)

    Narayan, Vikas

    at Risø and a 6 MW LTCFB gasifier owned by DONG ENERGY and placed in Kalundborg. In addition to the analysis of the inorganic elemental composition of the collected samples, SEM and TGA analysis of the samples were made to improve understanding on the behavior of the ash forming species within the system...... the bed particle diameters and the fraction of K entrained from the system. The model was also applied to study the de-fluidization behavior of alkali-rich samples in a large scale LTCFB gasifier. The model was used to predict the variations in de-fluidization time on a full scale LTCFB plant with respect...... ensures that high-alkali biomass fuels can be used without risks of bed de-fluidization. This thesis aims to understand the behavior of alkali metals and ash in the LTCFB system. The thesis work involved measurements made on bed material and product gas dust samples on a 100kW LTCFB gasifier placed...

  17. The Rheology of Acoustically Fluidized Sand

    Science.gov (United States)

    Conrad, J. W.; Melosh, J.

    2013-12-01

    The collapse of large craters and the formation of central peaks and peak rings is well modeled by numerical computer codes that incorporate the acoustic fluidization mechanism to temporarily allow the fluid-like flow of rock debris immediately after crater excavation. Furthermore, long runout landslides require a similar mechanism to explain their almost frictionless movement, which is probably also a consequence of their granular composition coupled with internal vibrations. Many different investigators have now confirmed the ability of vibrations to fluidize granular materials. Yet it still remains to fully describe the rheology of vibrated sand as a function of stress, frequency and amplitude of the vibrations in the sand itself. We constructed a rotational viscometer to quantitatively investigate the relation between the stress and strain rate in a horizontal bed of strongly vibrated sand. In addition to the macroscopic stain rate, the amplitude and frequency of the vibrations produced by a pair of pneumatic vibrators were also measured with the aid of miniaturized piezoelectric accelerometers (B&K 4393) whose output was recorded on a digital storage oscilloscope. The initial gathering of the experimental data was difficult due to granular memory, but by having the sand compacted vibrationally for 8 minutes before each run the scatter of data was reduced and we were able to obtain consistent results. Nevertheless, our major source of uncertainty was variations in strain rate from run to run. We find that vibrated sand flows like a highly non-Newtonian fluid, in which the shear strain rate is proportional to stress to a power much greater than one, where the precise power depends on the amplitude and frequency of the applied vibrations. Rapid flow occurs at stresses less than half of the static yield stress (that is, the yield stress when no vibration is applied) when strong vibrations are present. For a Newtonian fluid, such as water, the relation between

  18. Dust removal from waste gas arising from fluidized beds

    International Nuclear Information System (INIS)

    Soltys, L.

    1992-01-01

    Two types dust removal equipment mostly useful for dust removal from waste gas from fluidized beds, i.e. electrofilters and pulsatory bag filters were presented. Their features and functional properties were compared. (author). 7 refs, 4 figs

  19. Synchronized oscillations and acoustic fluidization in confined granular materials

    Science.gov (United States)

    Giacco, F.; de Arcangelis, L.; Ciamarra, M. Pica; Lippiello, E.

    2018-01-01

    According to the acoustic fluidization hypothesis, elastic waves at a characteristic frequency form inside seismic faults even in the absence of an external perturbation. These waves are able to generate a normal stress which contrasts the confining pressure and promotes failure. Here, we study the mechanisms responsible for this wave activation via numerical simulations of a granular fault model. We observe the particles belonging to the percolating backbone, which sustains the stress, to perform synchronized oscillations over ellipticlike trajectories in the fault plane. These oscillations occur at the characteristic frequency of acoustic fluidization. As the applied shear stress increases, these oscillations become perpendicular to the fault plane just before the system fails, opposing the confining pressure, consistently with the acoustic fluidization scenario. The same change of orientation can be induced by external perturbations at the acoustic fluidization frequency.

  20. Gasification of rice husk in a fluidized bed reactor

    Energy Technology Data Exchange (ETDEWEB)

    Mansaray, K.G.

    1998-12-31

    The development of two mathematical models which simulate the performance of a dual distributor fluidized bed gasifier was described. The gasification of rice husks in the gasifier using air as the sole gasifying agent was investigated. The four stages of the study were: (1) modification of the existing fluidized bed gasifier and data acquisition system, (2) preliminary experimentation to assess the suitability of rice husks for gasification to determine the feasible range of operating conditions for fluidized bed gasification of rice husks and to obtain data for proper design of thermochemical conversion systems, (3) development of mathematical models to predict the performance of the fluidized bed gasification system, and (4) experimentation to investigate the effects of various operating variables on the performance of the gasifier and provide data to evaluate the validity of the models.

  1. Synthesis of carbon nanotubes using fluidized bed technology

    CSIR Research Space (South Africa)

    Swartbooi, AM

    2008-11-01

    Full Text Available virgin plastics as well as a carbonaceous gas using fluidized bed technology. Current investigations are underway to test various factors involved with the CNT growth and production. An understanding of these factors and their interactions could provide...

  2. La violencia sexual asociada al conflicto y las implicaciones políticas de investigaciones recientes

    Directory of Open Access Journals (Sweden)

    Elisabeth Jean Wood

    2016-07-01

    Full Text Available La academia ha venido documentando un creciente número de modalidades de violencia sexual asociadas a los conflictos, sus causas y la gran variabilidad que existe en cuanto a su ejecución por parte de las organizaciones armadas. En este trabajo resumo los resultados de investigaciones recientes sobre dicha variabilidad, con énfasis en los hallazgos que contradicen o complican las creencias populares. Luego, presento varias interpretaciones sobre la afirmación de que esa violencia es parte de una continuidad entre tiempos de paz y de guerra. Después de analizar las investigaciones recientes sobre las dinámicas internas de las organizaciones armadas, sugiero que las violaciones sexuales a gran escala a menudo ocurren como una práctica, en vez de una estrategia. Por último, propongo algunos principios para guiar las políticas en vista de las investigaciones recientes

  3. Nucla circulating atmospheric fluidized bed demonstration project

    Energy Technology Data Exchange (ETDEWEB)

    Keith, Raymond E.

    1991-10-01

    Colorado-Ute Electric Association began a study to evaluate options for upgrading and extending the life of its Nucla power station in 1982. Located in southwestern Colorado near the town of Nucla, this station was commissioned in 1959 with a local bituminous coal as its design fuel for three identical stoker-fired units, each rated at 12.6 MW(e). Poor station efficiency, high fuel costs, and spiraling boiler maintenance costs forced the Nucla Station into low priority in the CUEA dispatch order as early as 1981. Among the options CUEA considered was to serve as a host utility to demonstrate Atmospheric Fluidized Bed Combustion (AFBC) technology. The anticipated environmental benefits and apparent attractive economics of a circulating AFBC led to Colorado-Ute's decision to proceed with the design and construction of a demonstration project in 1984 at the Nucla facility.

  4. Fluidized Bed Sputtering for Particle and Powder Metallization

    Science.gov (United States)

    2013-04-01

    Sathiyamoorthy provides a review of plasma technology used with fluidized bed techniques (13). Borer and von Rohr integrated a microwave plasma source...Plasma Spouted/Fluidized Bed for Materials Processing. Journal of Physics: Conference Series 2010, 208 (1), 012120. 14. Borer, B.; von Rohr , R...Technology 2005, 200, 377–381. 15. Morstein, M.; Karches, M.; Bayer, C.; Casanova, D.; von Rohr , P. R. Plasma CVD of Ultrathin TiO2 Films on Powders in a

  5. Fluidized-bed calciner with combustion nozzle and shroud

    International Nuclear Information System (INIS)

    Wielang, J.A.; Palmer, W.B.; Kerr, W.B.

    1977-01-01

    A nozzle employed as a burner within a fluidized bed is coaxially enclosed within a tubular shroud that extends beyond the nozzle length into the fluidized bed. The open-ended shroud portion beyond the nozzle end provides an antechamber for mixture and combustion of atomized fuel with an oxygen-containing gas. The arrangement provides improved combustion efficiency and excludes bed particles from the high-velocity, high-temperature portions of the flame to reduce particle attrition. 4 claims, 2 figures

  6. Chebyshev super spectral viscosity method for a fluidized bed model

    International Nuclear Information System (INIS)

    Sarra, Scott A.

    2003-01-01

    A Chebyshev super spectral viscosity method and operator splitting are used to solve a hyperbolic system of conservation laws with a source term modeling a fluidized bed. The fluidized bed displays a slugging behavior which corresponds to shocks in the solution. A modified Gegenbauer postprocessing procedure is used to obtain a solution which is free of oscillations caused by the Gibbs-Wilbraham phenomenon in the spectral viscosity solution. Conservation is maintained by working with unphysical negative particle concentrations

  7. Chebyshev super spectral viscosity method for a fluidized bed model

    CERN Document Server

    Sarra, S A

    2003-01-01

    A Chebyshev super spectral viscosity method and operator splitting are used to solve a hyperbolic system of conservation laws with a source term modeling a fluidized bed. The fluidized bed displays a slugging behavior which corresponds to shocks in the solution. A modified Gegenbauer postprocessing procedure is used to obtain a solution which is free of oscillations caused by the Gibbs-Wilbraham phenomenon in the spectral viscosity solution. Conservation is maintained by working with unphysical negative particle concentrations.

  8. Power quality. Analysis of the losses related to the tension and current distortion in the electric network; Calidad de la energia electrica. Analisis de las perdidas relacionadas con la distorsion de la tension y corriente de la red electrica

    Energy Technology Data Exchange (ETDEWEB)

    Rauch Sitar, Vladimir [Universidad Autonoma de Queretaro, Facultad de Ingenieria, Queretaro (Mexico)

    1994-12-31

    In recent times every day one speaks more about power quality and about the losses produced by the tension and current distortion. The distortion in the electric network and the consumption tend to keep on increasing, and each day there will be the need of applying more resources to handle it inside a reasonable range. In this article the situation of the power quality is analyzed in the most general case and also simplified for special cases. On base on the distortion coefficients of tension and current a matrix is created where the harmonics coefficients of tension as well as the current appear in an organized form an all of the elements of that matrix are analyzed. Some topological rules are created in order to give the simplest orientation in the complex situation. The article is useful to supervise the power quality in all of the typical cases and establish a base for a more detailed analysis. [Espanol] En los ultimos tiempos cada dia mas se esta hablando sobre la calidad de la energia electrica (Power Quality) y sobre las perdidas provocadas con este factor. La distorsion de la red electrica y del consumo tiene la tendencia de seguir aumentando y cada dia mas habra que dedicar mas recursos para manejarla dentro de un rango razonable. En el articulo presentado se analiza la situacion de la calidad de energia en caso mas general y tambien simplificada para los casos especiales. A base de coeficientes de distorsion, de tension y corriente se crea una Matriz donde figuran tanto los coeficientes de armonicas de tension como de corriente en una forma ordenada y se analizan todos los elementos de esta matriz. Se crean algunas reglas topologicas para dar la orientacion mas simple en la situacion compleja. El articulo sirve para dar supervision a la calidad de energia en todos los casos tipicos y establecer una base para el analisis mas detallado.

  9. Pulsed atmospheric fluidized bed combustion. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1989-11-01

    In order to verify the technical feasibility of the MTCI Pulsed Atmospheric Fluidized Bed Combustor technology, a laboratory-scale system was designed, built and tested. Important aspects of the operational and performance parameters of the system were established experimentally. A considerable amount of the effort was invested in the initial task of constructing an AFBC that would represent a reasonable baseline against which the performance of the PAFBC could be compared. A summary comparison of the performance and emissions data from the MTCI 2 ft {times} 2 ft facility (AFBC and PAFBC modes) with those from conventional BFBC (taller freeboard and recycle operation) and circulating fluidized bed combustion (CFBC) units is given in Table ES-1. The comparison is for typical high-volatile bituminous coals and sorbents of average reactivity. The values indicated for BFBC and CFBC were based on published information. The AFBC unit that was designed to act as a baseline for the comparison was indeed representative of the larger units even at the smaller scale for which it was designed. The PAFBC mode exhibited superior performance in relation to the AFBC mode. The higher combustion efficiency translates into reduced coal consumption and lower system operating cost; the improvement in sulfur capture implies less sorbent requirement and waste generation and in turn lower operating cost; lower NO{sub x} and CO emissions mean ease of site permitting; and greater steam-generation rate translates into less heat exchange surface area and reduced capital cost. Also, the PAFBC performance generally surpasses those of conventional BFBC, is comparable to CFBC in combustion and NO{sub x} emissions, and is better than CFBC in sulfur capture and CO emissions even at the scaled-down size used for the experimental feasibility tests.

  10. INVESTIGACIONES DE LAS REPRESENTACIONES SOCIALES DEL MEDIO AMBIENTE EN BRASIL Y MÉXICO

    Directory of Open Access Journals (Sweden)

    Raúl Calixto Flores

    2013-01-01

    Full Text Available En este artículo se describen algunas investigaciones sobre las representaciones sociales del medio ambiente en Brasil y en México, con el objetivo de observar las implicaciones de estos estudios para la educación ambiental; destaca el hecho de que sus resultados son coincidentes, a pesar de que sean distintas culturas y lenguajes, así como diferentes grupos de población y niveles educativos. La exploración de las investigaciones muestra la pertinencia del empleo de la teoría de las representaciones sociales, para identificar, comprender y explicar el pensamiento social en el campo de la educación ambiental. Los autores más citados en las investigaciones anteriormente referidas son Denise Jodelet, Serge Moscovici, Marcos Reigota y Jean Claude Abric. Durante esta breve revisión, se observa el predominio de las investigaciones realizadas con estudiantes, la mayoría utiliza una metodología cualitativa y un enfoque interpretativo. En las diversas investigaciones analizadas, sobre las representaciones del medio ambiente, se evidencia su importancia para comprender la práctica de la educación ambiental. Por ende, para la educación ambiental resulta fundamental comprender las formas en que se establecen las representaciones sociales, en la desconstrucción-construcción de los elementos que forman su pensamiento cotidiano. Considerando los resultados de las investigaciones revisadas, se puede afirmar que el medio ambiente es un objeto social complejo, cultural y contextualmente determinado.

  11. INVESTIGACIONES DE LAS REPRESENTACIONES SOCIALES DEL MEDIO AMBIENTE EN BRASIL Y MÉXICO

    OpenAIRE

    Raúl Calixto Flores

    2013-01-01

    Resumen: En este artículo se describen algunas investigaciones sobre las representaciones sociales del medio ambiente en Brasil y en México, con el objetivo de observar las implicaciones de estos estudios para la educación ambiental; destaca el hecho de que sus resultados son coincidentes, a pesar de que sean distintas culturas y lenguajes, así como diferentes grupos de población y niveles educativos. La exploración de las investigaciones muestra la pertinencia del empleo de la teoría de las ...

  12. Electric energy saving in the cellulose and paper industry; Ahorro de energia electrica en la industria de celulosa y papel

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-12-31

    This paper delineates the results of the demonstration project for electric energy saving, which is one of the twenty four projects in which the Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) sponsors the diagnosis as well as the applied measures and the measures currently in application. Also the potential opportunity areas and the measures applied and in course of application, as well as the required investments and their recuperation periods. [Espanol] En este trabajo se describen los resultados del proyecto de demostracion de ahorro de energia electrica que es uno de los veinticuatro proyectos, en los que el Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) financia tanto el diagnostico como la aplicacion de medidas. Se presentan tanto las areas de oportunidad, potenciales y medidas aplicadas y en aplicacion, asi como las inversiones requeridas y los periodos de recuperacion de las mismas.

  13. Price models of electrical energy, via stochastic processes; Modelos de precios de energia electrica, via procesos estocasticos

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Ramos, Hugo

    2008-12-15

    The electrical energy prices own very particular characteristics that make them different from the prices of any good which are immersed under the fluctuation of the laws of supply and demand. The present work proposes a revision and modification of the model for the prices of electrical energy based on stochastic processes, developed in 2002 by M.T. Barlow. Our model satisfactorily explains the dynamics of the prices, having as an example the case of the energy market of Alberta, CA. The proposed model is based on the power transformation of Yeo-Johnson in 2000, which does not have dominion restrictions. Also, it is assumed that the energy price depends on the demand, which is modeled as a process of Ornstein-Uhlenbeck. The proposed model was applied to real data, obtaining corresponding estimations of the interest parameters, as well as their validation. Also simulation results are shown to determine the empirical distribution of the estimators of maximum credibility of the parameters. [Spanish] Los precios de energia electrica poseen caracteristicas muy particulares que los hacen diferentes a los precios de cualquier bien que estan inmersos bajo la fluctuacion de las leyes de la oferta y la demanda. El presente trabajo propone una revision y modificacion del modelo para los precios de energia electrica basado en procesos estocasticos, desarrollado en 2002 por M. T. Barlow. Nuestro modelo explica satisfactoriamente la dinamica de los precios, teniendo como ejemplo el caso del mercado de energia de Alberta, Ca. El modelo propuesto esta basado en la transformacion potencia de Yeo-Johnson en 2000, la cual no tiene restricciones de dominio. Tambien, se asume que el precio de la energia depende de la demanda, la cual es modelada como un proceso de Ornstein-Uhlenbeck. El modelo propuesto se aplico a datos reales, obteniendo estimaciones correspondientes de los parametros de interes, asi como su validacion. Tambien se muestran resultados de simulacion para determinar la

  14. The electric energy in Mexico and the sustainable development; La energia electrica en Mexico y el desarrollo sustentable

    Energy Technology Data Exchange (ETDEWEB)

    Campos Aragon, Leticia [Instituto de Investigaciones Economicas, Universidad Nacional Autonoma de Mexico (UNAM), Mexico, D. F. (Mexico)

    1997-12-31

    This document explains the importance of the sustainable development in the electric energy, that is, that the technological advances in the electric sector do no hamper the future of the generations to come and generate potential problems such as: environmental pollution, unnecessary expenses in the realization of new technologies already executed. Mention is made of the relationship between nature and society, the ecological crisis, and the electric energy, seven points are given on how to control and treat waste waters, three points are given to handle and dispose of solid wastes, finally four points are given on the noise contamination control. It is concluded that the problem of reducing the environmental impact of the generation of electricity does not depend on the applied technology, since there are technological options for its solution, but on other more complex factors that deal with the generation of wealth, its distribution and the population growing [Espanol] En el presente documento se explica la importancia del desarrollo sustentable en la energia electrica, es decir que los avances tecnologicos en el sector energetico no entorpezcan el futuro de las generaciones venideras y generen posibles problemas como: contaminacion del medio ambiente, gastos innecesarios en la realizacion de las nuevas tecnologias realizadas. Se menciona la relacion entre la naturaleza y la sociedad, la crisis ecologica y la energia electrica, se dan siete puntos de como controlar y tratar aguas residuales, se proporcionan tres puntos para manejar y disponer de residuos solidos, por ultimo se dan cuatro puntos sobre el control de la contaminacion por ruido. Se concluye en que el problema de reducir el impacto ambiental por la generacion de electricidad no depende de la tecnologia empleada pues existen alternativas tecnologicas para su solucion, sino en otros aun mas complejos que tienen que ver con la generacion de la riqueza, su distribucion y el crecimiento de la poblacion

  15. Towards a distributed electric generation scheme with non-conventional energies; Hacia un esquema de generacion electrica distribuida con energias no convencionales

    Energy Technology Data Exchange (ETDEWEB)

    Huacuz Villamar, Jorge M. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    Several factors contributed to the existence of large electric systems as we know them today, such as: the increase of the electric demand by the advancement of the industrial development, the appearance of electric equipment, and household devices and by the advancement in the engineering systems, just to mention a few of them. With all this, the third part of the World population still does not have access to the electricity service. The efforts that the small electric enterprises perform to carry the service up to the site where it is required, every day time becomes more expensive and less effective. Exhausted by the weight of a huge economic debt, many electric utilities of the developing countries find each time more difficult to obtain financing to extend the power lines. This situation becomes still more serious with the present privatization scheme of the electric utilities. Although new technologies are being developed to counteract the negative effects caused by the large electricity generation power plants, the society seems to begin to show preferences for more benign to the environment options. The scheme of distributed generation can be given in to modalities: By means of isolated systems in remote sites, where there is not access to the conventional services; and with systems interconnected with the electric network where this is available [Espanol] Varios factores contribuyeron a la aparicion de los grandes sistemas electricos como los conocemos hoy en dia, tales como: el crecimiento de la demanda electrica por el avance del desarrollo industrial, la aparicion de equipos electricos y aparatos electrodomesticos y por avances en la ingenieria de los sistemas, por mencionar algunos. Con todo ello, la tercera parte de la poblacion mundial no tiene aun acceso al servicio electrico. Los esfuerzos que realizan las companias electricas para llevar el servicio hasta donde se requiere, resultan cada vez mas costosos y menos efectivos. Agobiadas por el peso

  16. Gas back-mixing studies in membrane assisted bubbling fluidized beds

    NARCIS (Netherlands)

    Deshmukh, S.A.R.K.; van Sint Annaland, M.; Kuipers, J.A.M.

    2007-01-01

    Fluidized beds employing fine powders are finding increased application in the chemical and petrochemical industry because of their excellent mass and heat transfer characteristics. However, in fluidized bed chemical reactors axial gas back mixing can strongly decrease the conversion and

  17. El aprendizaje significativo en las ciencias al participar en proyectos de investigacion cientifica

    Science.gov (United States)

    Mora Polanco, Miguelena

    La ciencia es el eje fundamental a traves del cual se desarrollan las habilidades necesarias para el pensar cientifico que va a la busqueda del conocimiento cientifico. La intencion de este estudio fue indagar en el tema de investigacion cientifica desde el punto de vista de los participantes en los siguientes aspectos relacionados con la experiencia de investigacion cientifica: a) conceptos, b) proceso, c) destrezas y d) disposicion. Tambien se analizaron: a) las perspectivas del metodo cientifico, b) la estrategia de ensenanza, c) la cultura cientifica y d) la exposicion del proyecto investigativo en la Feria Cientifica; como parte del aprendizaje significativo de la ciencias de los participantes. Esta investigacion cualitativa propuso como diseno el estudio de caso. Los aspectos relacionados a la experiencia de participar en proyecto de investigacion cientifica son el fenomeno o caso bajo estudio. En el estudio participaron cinco (5) estudiantes egresados de escuela publica o privada que cursaban hasta el tercer ano de estudios universitarios, conducentes a un bachillerato en educacion secundaria en ciencias o en ciencias naturales. Las tecnicas utilizadas para recopilar los datos fueron: analisis de documentos del DEPR, revision de artefactos y entrevistas profundas. Para el analisis de los datos de las entrevistas se utilizo el modelo de Wolcott (1994). Del analisis de documentos del DEPR se identificaron areas a mejorar en las guias de las cartas circulares con relacion a la investigacion escolar y la feria cientifica. El analisis de los artefactos proveyo evidencia de como los internados, simposios e investigaciones fomentan el que los estudiantes se superen en el aspecto cognitivo, se conviertan en creadores del conocimiento, al hacer suyo los conceptos para poder explicarlos al publico. De las entrevistas los participantes manifestaron que la experiencia de investigacion fue una de aprendizaje significativo que los marco para toda la vida y les expandio su

  18. Analysis methodology for economic technical feasibility studies in offshore electrical generation systems; Metodologia de analisis para estudios de factibilidad tecnica economica en sistemas de generacion electrica costa fuera

    Energy Technology Data Exchange (ETDEWEB)

    Fiscal Escalante, Raul [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2007-07-01

    An analysis methodology followed in the development of technique-economic feasibility studies of systems of electrical generation in offshore electrical installations is presented, including the obtaining of the curves of the turbine and generator performance, the technical considerations for the formulation of the operation scenes and the calculations of the economic evaluation of a real scenario. [Spanish] Se muestra una metodologia de analisis seguida en el desarrollo de estudios de factibilidad tecnica-economica de sistemas de generacion electrica en instalaciones electricas costa fuera, incluyendo la obtencion de las curvas de comportamiento de la turbina y el generador, las consideraciones tecnicas para la formulacion de los escenarios de operacion y los calculos de la evaluacion economica de un escenario real.

  19. The new financing techniques and the reorganization of the Mexican electric industry; Las nuevas tecnicas de financiamiento y la reorganizacion de la industria electrica mexicana

    Energy Technology Data Exchange (ETDEWEB)

    Islas Samperio, Jorge; Rodriguez Viqueira, Luis [Instituto de Ingenieria, Universidad Nacional Autonoma de Mexico (UNAM), D. F. (Mexico)

    1997-12-31

    The exhaustion of the financing model of the Mexican Electric Industry based on foreign credits, the State contribution and in a small part from auto-financing, has determined the search for new financing sources for the investment in this capital intensive sector. The main characteristic of the State new strategy to increase the investment capacity is to incite the private capital to make massive investments in the electric production segment. Nevertheless, there are different modalities to make the private capital participate in this sector`s segment. In this paper we make an analysis of the new financing techniques and their relationship with the regulations and the electric industry structure. Finally, the role of the conservation and the appropriate use of the energy is discussed as a mechanism for the modulation of the pressures coming from the financial sphere over the reorganization process of the National electric industry. [Espanol] El agotamiento del modelo de financiamiento de la industria electrica mexicana que tiene como base los creditos extranjeros, los aportes del estado y una pequena parte de autofinanciamiento, ha determinado la busqueda de nuevas fuentes de financiamiento de las inversiones de este sector intensivo en capital. La caracteristica principal de la nueva estrategia del estado para aumentar la capacidad de inversion es la de incitar al capital privado a realizar inversiones masivas en el segmento de la produccion electrica. Existen sin embargo diferentes modalidades para hacer participar al capital privado en este segmento del sector. En el presente trabajo hacemos un analisis de las nuevas tecnicas de financiamiento y sus relaciones con la reglamentacion y la estructura de la industria electrica. Por ultimo, se discute el papel del ahorro y uso eficiente como mecanismo para modular las presiones provenientes de la esfera financiera sobre el proceso de reorganizacion de la industria electrica nacional.

  20. Principles of a novel multistage circulating fluidized bed reactor for biomass gasification

    NARCIS (Netherlands)

    Kersten, Sascha R.A.; Prins, W.; van der Drift, Bram; van Swaaij, Willibrordus Petrus Maria

    2003-01-01

    In this paper a novel multistage circulating fluidized bed reactor has been introduced. The riser of this multistage circulating fluidized bed consists of several segments (seven in the base-case design) in series each built-up out of two opposite cones. Due to the specific shape, a fluidized bed

  1. An experimental study of the effect of collision properties on spout fluidized bed dynamics

    NARCIS (Netherlands)

    van Buijtenen, M.S.; Börner, Matthias; Deen, N.G.; Heinrich, Stefan; Antonyuk, Sergiy; Kuipers, J.A.M.

    2009-01-01

    In this paper we experimentally study the effect of collision properties of different particle systems on the bed dynamics of a spout fluidized bed. This is done in different flow regimes: the spout-fluidization regime (case A), the jet-in-fluidized-bed regime (case B) and the spouting-with-aeration

  2. Artificial neural network models for biomass gasification in fluidized bed gasifiers

    DEFF Research Database (Denmark)

    Puig Arnavat, Maria; Hernández, J. Alfredo; Bruno, Joan Carles

    2013-01-01

    Artificial neural networks (ANNs) have been applied for modeling biomass gasification process in fluidized bed reactors. Two architectures of ANNs models are presented; one for circulating fluidized bed gasifiers (CFB) and the other for bubbling fluidized bed gasifiers (BFB). Both models determin...

  3. Application of sedimentation model to uniform and segregated fluidized beds

    Energy Technology Data Exchange (ETDEWEB)

    Shippy, J.L. III; Watson, J.S.

    1990-10-24

    This paper incorporates concepts of unimodal and bimodal sedimentation to develop a model that accurately predicts bed expansion during particulate fluidization. During bed expansion a particle is considered to be fluidized not by the pure fluid, but by a slurry consisting of the pure fluid and other surrounding particles. The contributions of the other surrounding particles to the additional buoyant and drag forces are accounted for with the use of effective fluid or slurry properties, density and viscosity. As bed expansion proceeds, influences of the surrounding particles decrease; therefore, these effective properties are functions of the changing void fraction of the suspension. Furthermore, the expansion index, which empirically represents the degree to which viscous and inertial forces are present, is traditionally a function of a constant terminal Reynold's number. Because the effective fluid properties are considered to be changing as fluidization proceeds, the degree to which viscous and inertial forces also changes; therefore, the expansion index is written as a function of a local or intermediate Reynold's number. These concepts are further extended to bimodal fluidization in which small or light particles aid in the fluidization of the large or heavy particles. The results indicate that the proposed model more accurately predicts particulate bed expansion for a wider range of systems (gas -- liquid, low Reynold's number -- high Reynold's number) than other analytical or empirical models.

  4. Process analysis of fluidized bed granulation.

    Science.gov (United States)

    Rantanen, J; Jørgensen, A; Räsänen, E; Luukkonen, P; Airaksinen, S; Raiman, J; Hänninen, K; Antikainen, O; Yliruusi, J

    2001-10-17

    This study assesses the fluidized bed granulation process for the optimization of a model formulation using in-line near-infrared (NIR) spectroscopy for moisture determination. The granulation process was analyzed using an automated granulator and optimization of the verapamil hydrochloride formulation was performed using a mixture design. The NIR setup with a fixed wavelength detector was applied for moisture measurement. Information from other process measurements, temperature difference between process inlet air and granules (T(diff)), and water content of process air (AH), was also analyzed. The application of in-line NIR provided information related to the amount of water throughout the whole granulation process. This information combined with trend charts of T(diff) and AH enabled the analysis of the different process phases. By this means, we can obtain in-line documentation from all the steps of the processing. The choice of the excipient affected the nature of the solid-water interactions; this resulted in varying process times. NIR moisture measurement combined with temperature and humidity measurements provides a tool for the control of water during fluid bed granulation.

  5. COMPUTATIONAL MODELING OF CIRCULATING FLUIDIZED BED REACTORS

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Essam A

    2013-01-09

    Details of numerical simulations of two-phase gas-solid turbulent flow in the riser section of Circulating Fluidized Bed Reactor (CFBR) using Computational Fluid Dynamics (CFD) technique are reported. Two CFBR riser configurations are considered and modeled. Each of these two riser models consist of inlet, exit, connecting elbows and a main pipe. Both riser configurations are cylindrical and have the same diameter but differ in their inlet lengths and main pipe height to enable investigation of riser geometrical scaling effects. In addition, two types of solid particles are exploited in the solid phase of the two-phase gas-solid riser flow simulations to study the influence of solid loading ratio on flow patterns. The gaseous phase in the two-phase flow is represented by standard atmospheric air. The CFD-based FLUENT software is employed to obtain steady state and transient solutions for flow modulations in the riser. The physical dimensions, types and numbers of computation meshes, and solution methodology utilized in the present work are stated. Flow parameters, such as static and dynamic pressure, species velocity, and volume fractions are monitored and analyzed. The differences in the computational results between the two models, under steady and transient conditions, are compared, contrasted, and discussed.

  6. Fluidized bed combustion and gasification of corncobs

    Energy Technology Data Exchange (ETDEWEB)

    Butuk, N.; Morey, R.V.

    1987-01-01

    A 15.2 cm (6 in) diameter fluidized bed reactor was evaluated in combustion and gasification modes using hammer milled corncobs with average particle size of 0.2 cm (0.08 in). Combustion tests were run at 10 and 32% w.b. moisture contents and 710 degrees C and 815 degrees C bed temperatures. Heat output rates of 13.4 to 16.2 MJ/h were achieved. Gasification tests were run at 10 and 22% w.b. moisture contents and 710 degrees C bed temperature, and heat output rates of 84 to 133 MJ/h were achieved. Particulates in the exhaust gases were determined in both the combustion and gasification modes of operation. The measurements showed the inadequacy of the flame holder for flaring the gas in the gasification mode. A combustion model based on elemental balances and the first law of thermodynamics was developed and compared to experimental results. The model adequately predicted fuel-air ratios and exhaust gas mass fractions in the combustion mode.

  7. Radioisotope applications on fluidized catalytic cracking units

    International Nuclear Information System (INIS)

    Charlton, J.S.

    1997-01-01

    Radioisotopes are used to trace the flow of all the phases of Fluidized Catalytic Cracking process in oil refineries. The gaseous phases, steam, hydrocarbon vapour and air, are generally traced using a noble-gas isotope, 41 Ar, 79 Kr or 85 Kr. An appropriate tracer for the catalyst is produced by irradiating a catalyst sample in a nuclear reactor. The activation products, 140 La and 24 Na provide appropriate radioactive 'labels' for the catalyst, which is reinjected into the FCC. An advantage of this approach is that it facilitates the study of the behaviour of different particle size fractions. Radioisotopes as sealed sources of gamma radiation are used to measure catalyst density variations and density distributions in critical parts of the unit. An important trend in radioisotope applications is the increasing use of the information they produce as inputs to or as validation of, mathematical process models. In line with the increasing sophistication of the models, the technology is undergoing continuous refinement. Developments include the investigation of more efficient, more convenient tracers, the introduction of systems to facilitate more rapid and comprehensive data acquisition and software refinements for enhanced data analysis

  8. Understanding and predicting bed humidity in fluidized bed granulation.

    Science.gov (United States)

    Hu, Xinhui; Cunningham, John; Winstead, Denita

    2008-04-01

    Bed humidity is a critical parameter that needs to be controlled in a fluidized bed granulation to ensure reliability. To predict and control the bed humidity during the fluidized bed granulation process, a simple model based on the mass conservation of moisture was developed. The moisture mass balance model quantitatively simulates the effects of spray rate, binder solution concentration, airflow rate, inlet air temperature, and dew point on the bed humidity. The model was validated by a series of granulations performed in different scale granulators including Glatt GPCG-1, GPCG-15, and GPCG-60. Good agreement was observed between the theoretical prediction and the measured loss on drying (LOD). The model developed in the current work enables us to choose the appropriate parameters for the fluidized bed granulation and can be used as a valuable tool in process scaling-up. 2007 Wiley-Liss, Inc

  9. Experimental study of fluidized bed agglomeration of acerola powder

    Directory of Open Access Journals (Sweden)

    G. C. Dacanal

    2008-03-01

    Full Text Available The aim of this work was to study the main effects of acerola powder on fluidized bed agglomeration. A 2(4-1 fractional factoring design was used to evaluate the main operating conditions (fluidizing air temperature, fluidizing air velocity, atomizing air flow and height of nozzle in the bed. The mechanical and physicochemical product changes were determined by analysis of particle diameter, moisture content, wetting time and bed porosity. The particle enlargement by agglomeration occurred when the relative humidity in the bed increased and, thus, the moisture of the product increased. However, the excessive increase in relative humidity resulted in a decrease in yield, caused by caking and product incrustation. The consolidation of small granules resulted in an increase in the instant properties, decreasing the wetting time and increasing the solubility in a short period of agitation.

  10. Thermal denitrification of evaporators concentrates in reactor with fluidized bed

    International Nuclear Information System (INIS)

    Brugnot, C.

    1993-11-01

    As part of the treatments of liquid wastes coming from the Marcoule reprocessing plant, the study of a thermal denitrification process for evaporator concentrates has been chosen by the CEA/CEN Cadarache: the fluidized-bed calcination. This work presents the study of a calcination pilot-plant for wastes with a very high sodium nitrate content. After a reactional analysis carried out in a thermobalance on samples which are representative of the fluidized-bed compounds, the perfecting of many of the plant parameters - such as the solution injection system - was carried out on a scale-model at first. Then, it was verified on the pilot-plant, and some experiments have been carried out. A mathematical model for the particle growth inside the fluidized-bed is proposed. (author). 179 refs., 65 figs., 23 tabs

  11. Computational fluid dynamic modeling of fluidized-bed polymerization reactors

    Energy Technology Data Exchange (ETDEWEB)

    Rokkam, Ram [Iowa State Univ., Ames, IA (United States)

    2012-01-01

    Polyethylene is one of the most widely used plastics, and over 60 million tons are produced worldwide every year. Polyethylene is obtained by the catalytic polymerization of ethylene in gas and liquid phase reactors. The gas phase processes are more advantageous, and use fluidized-bed reactors for production of polyethylene. Since they operate so close to the melting point of the polymer, agglomeration is an operational concern in all slurry and gas polymerization processes. Electrostatics and hot spot formation are the main factors that contribute to agglomeration in gas-phase processes. Electrostatic charges in gas phase polymerization fluidized bed reactors are known to influence the bed hydrodynamics, particle elutriation, bubble size, bubble shape etc. Accumulation of electrostatic charges in the fluidized-bed can lead to operational issues. In this work a first-principles electrostatic model is developed and coupled with a multi-fluid computational fluid dynamic (CFD) model to understand the effect of electrostatics on the dynamics of a fluidized-bed. The multi-fluid CFD model for gas-particle flow is based on the kinetic theory of granular flows closures. The electrostatic model is developed based on a fixed, size-dependent charge for each type of particle (catalyst, polymer, polymer fines) phase. The combined CFD model is first verified using simple test cases, validated with experiments and applied to a pilot-scale polymerization fluidized-bed reactor. The CFD model reproduced qualitative trends in particle segregation and entrainment due to electrostatic charges observed in experiments. For the scale up of fluidized bed reactor, filtered models are developed and implemented on pilot scale reactor.

  12. Iron crystallization in a fluidized-bed Fenton process.

    Science.gov (United States)

    Boonrattanakij, Nonglak; Lu, Ming-Chun; Anotai, Jin

    2011-05-01

    The mechanisms of iron precipitation and crystallization in a fluidized-bed reactor were investigated. Within the typical Fenton's reagent dosage and pH range, ferric ions as a product from ferrous ion oxidation would be supersaturated and would subsequently precipitate out in the form of ferric hydroxide after the initiation of the Fenton reaction. These precipitates would simultaneously crystallize onto solid particles in a fluidized-bed Fenton reactor if the precipitation proceeded toward heterogeneous nucleation. The heterogeneous crystallization rate was controlled by the fluidized material type and the aging/ripening period of the crystallites. Iron crystallization onto the construction sand was faster than onto SiO(2), although the iron removal efficiencies at 180 min, which was principally controlled by iron hydroxide solubility, were comparable. To achieve a high iron removal rate, fluidized materials have to be present at the beginning of the Fenton reaction. Organic intermediates that can form ferro-complexes, particularly volatile fatty acids, can significantly increase ferric ion solubility, hence reducing the crystallization performance. Therefore, the fluidized-bed Fenton process will achieve exceptional performance with respect to both organic pollutant removal and iron removal if it is operated with the goal of complete mineralization. Crystallized iron on the fluidized media could slightly retard the successive crystallization rate; thus, it is necessary to continuously replace a portion of the iron-coated bed with fresh media to maintain iron removal performance. The iron-coated construction sand also had a catalytic property, though was less than those of commercial goethite. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Volatiles combustion in fluidized beds. Technical progress report, 4 March 1993--3 June 1993

    Energy Technology Data Exchange (ETDEWEB)

    Hesketh, R.P.

    1993-09-01

    The goal of this project is to investigate the conditions in which volatiles will burn within both the dense and freeboard regions of fluidized beds. Experiments using a fluidized bed operated at incipient fluidization will be performed to characterize the effect of particle surface area, initial fuel concentration, and particle type on the inhibition of volatiles within a fluidized bed. The work conducted during the period 4 March, 1993 through 3 June, 1993 is reported in this technical progress report. The work during this time period consists primarily of the startup and trouble shooting of the fluidized bed reactor and gas phase modeling of methane and propane.

  14. Refractory experience in circulating fluidized bed combustors, Task 7

    Energy Technology Data Exchange (ETDEWEB)

    Vincent, R.Q.

    1989-11-01

    This report describes the results of an investigation into the status of the design and selection of refractory materials for coal-fueled circulating fluidized-bed combustors. The survey concentrated on operating units in the United States manufactured by six different boiler vendors: Babcock and Wilcox, Combustion Engineering, Foster Wheeler, Keeler Dorr-Oliver, Pyropower, and Riley Stoker. Information was obtained from the boiler vendors, refractory suppliers and installers, and the owners/operators of over forty units. This work is in support of DOE's Clean Coal Technology program, which includes circulating fluidized-bed technology as one of the selected concepts being evaluated.

  15. Pressurized fluidized-bed combustion technology exchange workshop

    Energy Technology Data Exchange (ETDEWEB)

    ,

    1980-04-01

    The pressurized fluidized-bed combustion technology exchange workshop was held June 5 and 6, 1979, at The Meadowlands Hilton Hotel, Secaucus, New Jersey. Eleven papers have been entered individually into EDB and ERA. The papers include reviews of the US DOE and EPRI programs in this area and papers by Swedish, West German, British and American organizations. The British papers concern the joint program of the USA, UK and FRG at Leatherhead. The key factor in several papers is the use of fluidized bed combustors, gas turbines, and steam turbines in combined-cycle power plants. One paper examines several combined-cycle alternatives. (LTN)

  16. Atmospheric fluidized bed coal combustion research, development and application

    CERN Document Server

    Valk, M

    1994-01-01

    The use of fluidized bed coal combustion technology has been developed in the past decade in The Netherlands with a view to expanding the industrial use of coal as an energy supply. Various research groups from universities, institutes for applied science and from boiler industries participated and contributed to this research area. Comprehensive results of such recent experimentation and development work on atmospheric fluidized bed combustion of coal are covered in this volume. Each chapter, written by an expert, treats one specific subject and gives both the theoretical background as well a

  17. Transformations of calcium sulphates in solidified carbonated volatile fluidized ashes

    Directory of Open Access Journals (Sweden)

    Marian Jacek Łączny

    2017-01-01

    During the investigation it was assumed that calcium carbonate, being poorly water-soluble, would not react with the remaining components of the porous water of the volatile fluidized ash. Crystalline phases of calcium sulphates, anhydrite, gypsum and bassanite occurring in bound volatile fluidized ashes after carbonation demonstrate the possibility of crystallization in the presence of calcium carbonate. In particular, a change in the concentration of bassanite indicates that this phase, as a precursor to the crystallization of gypsum, may play a significant role in the process of binding carbonated volatile ashes.

  18. Boundary conditions for soft glassy flows: slippage and surface fluidization.

    Science.gov (United States)

    Mansard, Vincent; Bocquet, Lydéric; Colin, Annie

    2014-09-28

    We explore the question of surface boundary conditions for the flow of a dense emulsion. We make use of microlithographic tools to create surfaces with well controlled roughness patterns and measure using dynamic confocal microscopy both the slip velocity and the shear rate close to the wall, which we relate to the notion of surface fluidization. Both slippage and wall fluidization depend non-monotonously on the roughness. We interpret this behavior within a simple model in terms of the building of a stratified layer and the activation of plastic events by the surface roughness.

  19. Internal dust recirculation system for a fluidized bed heat exchanger

    Science.gov (United States)

    Gamble, Robert L.; Garcia-Mallol, Juan A.

    1981-01-01

    A fluidized bed heat exchanger in which air is passed through a bed of particulate material containing fuel disposed in a housing. A steam/water natural circulation system is provided in a heat exchange relation to the bed and includes a steam drum disposed adjacent the bed and a tube bank extending between the steam drum and a water drum. The tube bank is located in the path of the effluent gases exiting from the bed and a baffle system is provided to separate the solid particulate matter from the effluent gases. The particulate matter is collected and injected back into the fluidized bed.

  20. Multiphase Flow and Fluidization Continuum and Kinetic Theory Descriptions

    CERN Document Server

    Gidaspow, Dimitri

    1994-01-01

    Useful as a reference for engineers in industry and as an advanced level text for graduate engineering students, Multiphase Flow and Fluidization takes the reader beyond the theoretical to demonstrate how multiphase flow equations can be used to provide applied, practical, predictive solutions to industrial fluidization problems. Written to help advance progress in the emerging science of multiphase flow, this book begins with the development of the conservation laws and moves on through kinetic theory, clarifying many physical concepts (such as particulate viscosity and solids pressure) and i

  1. FLUIDIZED BED STEAM REFORMER MONOLITH FORMATION

    Energy Technology Data Exchange (ETDEWEB)

    Jantzen, C

    2006-12-22

    Fluidized Bed Steam Reforming (FBSR) is being considered as an alternative technology for the immobilization of a wide variety of aqueous high sodium containing radioactive wastes at various DOE facilities in the United States. The addition of clay, charcoal, and a catalyst as co-reactants converts aqueous Low Activity Wastes (LAW) to a granular or ''mineralized'' waste form while converting organic components to CO{sub 2} and steam, and nitrate/nitrite components, if any, to N{sub 2}. The waste form produced is a multiphase mineral assemblage of Na-Al-Si (NAS) feldspathoid minerals with cage-like structures that atomically bond radionuclides like Tc-99 and anions such as SO{sub 4}, I, F, and Cl. The granular product has been shown to be as durable as LAW glass. Shallow land burial requires that the mineralized waste form be able to sustain the weight of soil overburden and potential intrusion by future generations. The strength requirement necessitates binding the granular product into a monolith. FBSR mineral products were formulated into a variety of monoliths including various cements, Ceramicrete, and hydroceramics. All but one of the nine monoliths tested met the <2g/m{sup 2} durability specification for Na and Re (simulant for Tc-99) when tested using the Product Consistency Test (PCT; ASTM C1285). Of the nine monoliths tested the cements produced with 80-87 wt% FBSR product, the Ceramicrete, and the hydroceramic produced with 83.3 wt% FBSR product, met the compressive strength and durability requirements for an LAW waste form.

  2. Uso de la estadi?stica en trabajos de investigacio?n en la Universidad San Pedro

    OpenAIRE

    Lizarzaburu Montero, Lidia Marina

    2013-01-01

    La estadi?stica es una de las herramientas fundamentales de la investigacio?n cienti?fica. Su uso es ineludible en especial cuando se trabajan problemas de investigacio?n en los que se miden variables cuantitativas; y su importancia es mayor en los disen?os experimentales, en los cuales debe usarse para controlar la validez de los resultados del experimento. (Lizarzaburu et al., 2009) Su valor como herramienta de la investigacio?n radica en que permite conducir la experiencia de investigacio...

  3. Specification for the interconnection to a electric network of low tension of photovoltaic systems with 30 kW of capacity; Especificacion para la interconexion a la red electrica de baja tension de sistemas fotovoltaicos con capacidad hasta 30kW

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Gutierrez, Jose [Comision Federal de Electricidad, Mexico (Mexico)

    2007-06-15

    In this presentation, there are shown the details of the photovoltaic systems interconnected with the electric network (SFVI), carried out by the Mexico's Federal Electricity Commission (CFE) with the support of the Mexican Electric Research Institute (IIE). First of all, there are found the objectives of the photovoltaic system interconnected to the electric network (SFVI). Then, there are mentioned the places where such sort of systems could be installed; besides, it is shown a diagram explaining the process of such systems. At the same time, there are briefly explained the components that are necessaries for their properly operation. Some of the elements previously mentioned are: photovoltaic generator (GFV), inverter, interface, and logic circuits and the control. It is shown a diagram with the location of the electrical disconnect switches. Then, it is shortly explained the place where the SFVI should be connected and there are given some requisites that are important to fulfill in order to have everything updated. Finally, it is mentioned the methodology that should be followed in order to supervise that everything works in a properly way, this last issue is carried out by CFE. [Spanish] En esta presentacion se presentan los pormenores del sistema fotovoltaico interconectado a la red (SFVI), realizado por la Comision federal de Electricidad (CFE) con apoyo del Instituto de Investigaciones Electricas (IIE). En primer lugar, se encuentran los objetivos que tiene el uso de SFVI. Enseguida, se muestra un diagrama que explica el proceso que dichos sistemas realizan. Asimismo, se explican brevemente los elementos que, de uno u otro modo, son necesarios para el adecuado funcionamiento del SFV. Ademas, se muestra un diagrama con la ubicacion de los interruptores de desconexion. Luego, se explica escuetamente el lugar donde se debe de conectar el SFVI, ademas de algunas condiciones que se deben de cumplir para que no haya mayores contratiempos. Finalmente, se

  4. Modos de produccion cientifica: Culturas y metodologias de investigacion en la Universidad de Cadiz

    Science.gov (United States)

    Gonzalez Ramos, Ana M.

    2004-12-01

    Este trabajo de investigacion supone un modelo teorico de caracter aplicado, que proporciona la oportunidad de evaluar la produccion cientifica de los investigadores. Se encuadra dentro de la tradiccion de la estadistica aplicada y la sociologia del conocimiento. Atiende especialmente a dos conjuntos de temas de interes, por una parte, las caracteristicas principales que determinan el nivel y tipo de produccion academica producida por las unidades de investigacion y por los propios investigadores; por otra, la utilizacion que se hace de los metodos y tecnicas de investigacion puesto que de ello tambien depende el modo de produccion cientifica. Los puntos novedosos de esta tesis son: la medicion cuantitativa del objeto de estudio, la suma de los productos y las condiciones externas a la produccion del conocimiento mas otros elementos internos como las caracteristicas de los investigadores y la metodologia utilizada para desarrollar sus trabajos; y, finalmente, el uso de las nuevas tecnologias. El aprovechamiento de los recursos estadisticos y las fuentes de informacion secundarias se complementan con el diseno propio de una encuesta donde se implementa las caracteristicas descritas en un capitulo anterior sobre los metodos cientificos mas idoneos descritos en los principales manuales y articulos cientificos desde distintas disciplinas de conocimiento. Dicha encuesta ha sido desarrollada como un programa propio y en base a los mas innovadores usos de la tecnologia en la metodologia de encuestas.

  5. The Mexican electric industry under an opening triangle; La industria electrica mexicana bajo un triangulo de apertura

    Energy Technology Data Exchange (ETDEWEB)

    Suarez Guevara, Sergio [Instituto de Investigaciones Economicas, Universidad Nacional Autonoma de Mexico (UNAM), Mexico, D. F. (Mexico)

    1997-12-31

    This document analyzes the electric industry in Mexico in its opening phase, which must be qualified as a strategic activity within the present and future becoming of the Mexican economy. The Mexican electric sector was framed within the National Project born out in the country`s Politic Constitution; where the State economic intervention is driven and induced, with its exclusive duty in strategic activities through public enterprises created for that purpose and as a support of Mexico`s economic and social welfare. Within the opening it should be pointed out the participation of the North American Free Trade Agreement (NAFTA), the Energy Program, the Development Program and Restructure of the Energy Sector 1995-2000 [Espanol] En el presente documento se analiza la industria electrica en Mexico en su fase de apertura, la cual debe calificarse como una actividad estrategica dentro del devenir presente y futuro de la economia mexicana. El sector electrico mexicano se enmarco dentro del Proyecto Nacional que nace en la Constitucion Politica del pais; donde se impulsa e induce la intervencion economica del Estado, con su quehacer exclusivo en actividades estrategicas, por medio de empresas publicas creadas para tal fin y en apoyo del bienestar economico y social de Mexico. Dentro de la apertura hay que senalar la participacion que tiene el Tratado de Libre Comercio, el Programa de Energia y el Programa de Desarrollo y Reestructuracion del Sector Energia 1995-2000

  6. Application of unimodal optic fiber to communications among electric substations; Aplicacion de fibra optica unimodal a comunicaciones entre subestaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Pinon, Fernando; Hernandez Juarez, Taide [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1992-07-01

    The utilization of the unimodal fiber optics technology in the electric power systems, represents one of the best communication options because of its multiple advantages, that results in a better coordination of the technical and administrative activities, needed to carry the electric energy from its generation site to the most remote locations. In this document a study, in accordance with the available options for the design of communication systems via unimodal optic fiber, is presented. With this technology, ties of more than 100 kilometers without the need of repeating stations, can be made. [Espanol] La utilizacion de la tecnologia de fibra optica unimodal en los sistemas electricos de potencia representa una de las mejores alternativas de comunicacion por sus multiples ventajas que se traducen en una mejor coordinacion de las acitividades tecnicas y administrativas necesarias para llevar la energia electrica desde el lugar de generacion hasta los puntos mas distantes. En este documento se presenta un estudio de acuerdo a las opciones disponibles para el diseno de sistemas de comunicacion por fibra optica unimodal. Con esta tecnologia se pueden realizar enlaces mayores que 100 km sin necesidad de repetidores.

  7. On the entrainment of solid particles from a fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Sciazko, M. (Institute of Chemical Processing of Coal, Zabrze (Poland)); Bandrowski, J.; Raczek, J. (Politechnika Slaska, Gliwice (Poland). Inst. of Chemical Engineering and Apparatus Construction)

    1991-04-01

    This paper presents a generalized approach to the phenomenon of entrainment of solids from a fluidized bed. Starting with the discussion of the transport disengaging height (TDH) and of the elutriation of particles above the TDH, one arrives finally at the relationship between the elutriation rate constant, saturation carrying capacity and choking parameters of pneumatic transport. (orig.).

  8. Biofilm detachment mechanisms in a liquid-fluidized bed.

    Science.gov (United States)

    Chang, H T; Rittmann, B E; Amar, D; Heim, R; Ehlinger, O; Lesty, Y

    1991-08-20

    Bed fluidization offers the possibility of gaining the advantages of fixed-film biological processes without the disadvantage of pore clogging. However, the biofilm detachment rate, due to hydrodynamics and particle-to-particle attrition, is very poorly understood for fluidized-bed biofilm processes. In this work, a two-phase fluidized-bed biofilm was operated under a constant surface loading (0.09 mg total organic carbon/cm(2) day) and with a range of bed height (H), fluid velocities (U), and support-particle concentrations (C(p)). Direct measurements were made for the specific biofilm loss rate coefficient (b(s))and the total biofilm accumulation (X(f)L(f)). A hydrodynamic model allowed independent determination of the biofilm density (X(f)), biofilm thickness (L(f)), liquid shear stress (tau), and Reynolds number (Re). Multiple regression analysis of the results showed that increased particle-to-particle attrition, proportional to C(p) and increased turbulence, described by Re, caused the biofilms to be denser and thinner. The specific detachment rate coefficient (b(s)) increased as C(p) and Re increased. Almost all of the 6, values were larger than predicted by a previous model derived for smooth biofilms on a nonfluidized surface. Therefore, the turbulence and attrition of bed fluidization appear to be dominant detachment mechanisms.

  9. The heat transfer mechanisms in fluidized beds; Laemmoensiirtomekanismit leijukerroksessa

    Energy Technology Data Exchange (ETDEWEB)

    Fogelholm, C.J.; Blomster, A.M.; Kojola, H. [Helsinki Univ. of Technology, Otaniemi (Finland). Lab. of Energy Technology and Environmental Protection

    1997-10-01

    The goal of the research project is to improve the accuracy of the heat transfer correlation in circulating fluidized beds and to define how the heat transfer is distributed in radiation and convection in the different parts of the fluidized bed. This will be carried out by studying the behaviour and the heat transfer of the fluidized bed in the boundary layer near the wall. During the project the concentration and the velocity of the sand particles are measured. The particle concentration and the particle velocity are measured by an image analysis system. A video camera and a Super VHS recorder are used to capture live images from the bed. The images are digitized and stored on a PC. The measured particle concentration was at highest slightly over 20 % on the straight wall. As expected, the velocity of the fluidizing gas had the most important role on the particle concentration. The experimental studies of the particle velocity were started last autumn 1996. The velocities of the particles were measured by using a multiple exposure technique. Afterwards the images captured were analyzed by performing a Fourier transform analysis. So far the results have been encouraging and the analyzing work will be ended this spring. (orig.)

  10. substrate reduction kinetics and performance evaluation of fluidized

    African Journals Online (AJOL)

    eobe

    UASB reactor system before the treatment begins [6]. Open pit (aerobic) treatment system which is currently being employed at the brewery is characterized by high sludge generation with its attendant disposal problems. Slaughterhouse wastewater [7] and corn starch wastewater [8] have been treated using Fluidized-bed ...

  11. In silico modeling of in situ fluidized bed melt granulation.

    Science.gov (United States)

    Aleksić, Ivana; Duriš, Jelena; Ilić, Ilija; Ibrić, Svetlana; Parojčić, Jelena; Srčič, Stanko

    2014-05-15

    Fluidized bed melt granulation has recently been recognized as a promising technique with numerous advantages over conventional granulation techniques. The aim of this study was to evaluate the possibility of using response surface methodology and artificial neural networks for optimizing in situ fluidized bed melt granulation and to compare them with regard to modeling ability and predictability. The experiments were organized in line with the Box-Behnken design. The influence of binder content, binder particle size, and granulation time on granule properties was evaluated. In addition to the response surface analysis, a multilayer perceptron neural network was applied for data modeling. It was found that in situ fluidized bed melt granulation can be used for production of spherical granules with good flowability. Binder particle size had the most pronounced influence on granule size and shape, suggesting the importance of this parameter in achieving desired granule properties. It was found that binder content can be a critical factor for the width of granule size distribution and yield when immersion and layering is the dominant agglomeration mechanism. The results obtained indicate that both in silico techniques can be useful tools in defining the design space and optimization of in situ fluidized bed melt granulation. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Population balance modelling of fluidized bed melt granulation: an overview

    NARCIS (Netherlands)

    Tan, H.S.; Goldschmidt, M.J.V.; Boerefijn, R.; Hounslow, M.J.; Salman, A.; Kuipers, J.A.M.

    2005-01-01

    This paper presents an overview of the work undertaken by our group to identify and quantify the rates processes active in fluidized bed melt granulation (FBMG). The process involves the identification and development of physically representative models to mechanistically describe FBMG using both

  13. Study on biomass pyrolysis and gasification in a fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Su, X.; Wang, Z.; Cheng, C.; Tang, S.; Lu, Z.; Li, D. [Tsinghua University, Beijing (China). Thermal Engineering Department

    2000-08-01

    Experimental investigations of biomass pyrolysis and gasification were performed in a fluidized bed reactor with steam and nitrogen as fluid medium respectively. The size of the stainless steel reactor is 150mm ID and 1360mm in height. Five biomass samples including poplar sawdust, bagasse, cotton stem, eucalyptus globulus and pinus ratiata, have been tested on the facility at the temperatures ranging from 923K to 1073K. During each test run, biomass feedstock was fed into the reactor continuously for twelve minutes and without residue discharge, meanwhile seven gas samples were taken, five during the feeding process and two after the stop of feeding. The transient and accumulated gas yields were measured with a rotameter and a gas meter. The temperatures of the fluidized bed and freeboard were acquired by a system of thermocouples connected with a computer. The gas samples were analyzed on a gas chromatograph. On the basis of the experimental results, the variations of gas yield, gas composition, energy conversion efficiency and mass conversion efficiency with temperature are discussed for each biomass feedstock in both cases of steam and nitrogen fluidization. It has been revealed in this investigation that the presence of steam in the fluidized bed reactor stimulates tar cracking to form the gas species of C{sub 2}H{sub 4}and C{sub 2}H{sub 6}, etc. 8 ref., 15 figs., 6 tabs.

  14. Minimum slugging velocity in fluidized beds containing vertical rods

    Energy Technology Data Exchange (ETDEWEB)

    Coronella, C.J.; Lee, S.Y.; Seader, J.D. (University of Utah, Salt Lake City, UT (United States). Dept. of Chemical Engineering)

    1994-09-01

    A new method for determining the onset of slugging in fluidized beds is presented. Pressure-drop fluctuations, measured from below the distributor to the gas exit line, are transformed to the frequency domain by the power spectral desity function (PSDF). The dominant frequency of the PSDF corresponds to the eruption frequency of bubbles or slugs. A fluidized bed is in the slugging regime when this dominant frequency, f[sub d], remains constant with changing gas velocity. This method is an improvement over previous methods because of the simple nature of the apparatus required, and because it is possible to locate the pressure probes so that they do not interfere with the fluidization or undergo rapid wear from the constant particle movement. This method was used to determine the gas velocity corresponding to the transition from the bubbling to the slugging regime for a 10cm diameter bed of sand fluidized with air and containing three 1.9cm diameter vertical rods at 5.2cm centre-to-centre triangular spacing and extending the length of the bed, and to compare the results with those from the same bed without any internal rods. The presence of the vertical rods inhibited the onset of the slugging regime, and significantly extended the bubbling regime to higher gas velocities. 32 refs., 12 figs.

  15. The porosity in a fluidized bed heat transfer model

    NARCIS (Netherlands)

    Visser, G; Visser, G.; Valk, M.

    1993-01-01

    A mathematical model of heat transfer between a fluidized bed and an immersed surface and a model of gas flow and porosity, both recently published, were combined and further modified in the area of low velocities where the particle convective component of heat transfer is low or neglectable.

  16. Technological processes intensification in devices with magneto-fluidized bed

    Directory of Open Access Journals (Sweden)

    Egorov Ivan

    2017-01-01

    Full Text Available The paper shows the efficiency of application of magneto-fluidized bed formed of ferromagnetic materials in press-forms dosed filling and milling devices. For powders without natural fluidity, dosing device is situated between electromagnets creating constant magnetic field with horizontal induction lines and alternating gradient magnetic field with vertical induction lines and higher induction gradient in the lowest part of chamber with powder. This configuration allows development of uniform efflux speed of ferromagnetic powders from 2 mm diameter opening. For example, mass efflux speed of strontium ferrite powder with 1 μm average particle size in magneto-fluidized bed reached 181.1 mg/s and the dosing time of 2000 mg of this powder was 11.1 s. For practical usage of magneto-fluidized bed in the milling device, beater mill is situated between electromagnet poles in the way that induction lines of constant and alternating gradient magnetic fields were mutually perpendicular and parallel to the plane of rotating beaters. Milling of particulate strontium ferrite with 1558.5 μm average particle size during 120 minutes in magneto-fluidized bed allows increasing milling degree in 16.2 times by comparison with processing without electromagnetic effect.

  17. Physical Characteristics of Fluidized Beds via Pressure Fluctuation Analysis

    Czech Academy of Sciences Publication Activity Database

    Hartman, Miloslav; Trnka, Otakar

    2008-01-01

    Roč. 54, č. 7 (2008), s. 1761-1769 ISSN 0001-1541 R&D Projects: GA AV ČR IAA400720701 Institutional research plan: CEZ:AV0Z40720504 Keywords : gas-solid fluidization * pressure fluctuations * fluctuation characteristics Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.883, year: 2008

  18. Starch Wastewater Treatment in a Three Phase Fluidized Bed ...

    African Journals Online (AJOL)

    ... out in an inverse fluidized bed bioreactor using low density (870 kg/m3) polypropylene particles. Experiments were carried at different initial substrate concentration of 2250, 4475, 6730 and 8910mg COD/L and for various hydraulic retention time 40, 32, 24, 16 and 8h. Degradation of organic matter was studied at different ...

  19. Low temperature fluidized wood chip drying with monoterpene analysis

    Science.gov (United States)

    Bridget N. Bero; Alarick Reiboldt; Ward Davis; Natalie Bedard; Evan Russell

    2011-01-01

    This paper describes the drying of ponderosa pine wood chips at low (20°C and 50°C) temperatures using a bench-scale batch pulsed fluidizer to evaluate both volatile pine oils (monoterpenes) and moisture losses during drying.

  20. substrate reduction kinetics and performance evaluation of fluidized ...

    African Journals Online (AJOL)

    pilot scale anaerobic fluidized-bed reactor was operated for treating brewery wastewater at nine different hydraulic retention time (HRTs) of 2, 3, 4, 5, 6, 7, 8, 9, and 10hr. The COD reduction efficiencies increased from 9.8% to 74.1% with increasing HRT from 2 to 10hr.Similarly, the corresponding BOD5 reduction efficiencies ...

  1. Dissolved oxygen control in a coupled fluidized bed system

    International Nuclear Information System (INIS)

    Jones, R.M.; Melcer, H.

    1988-01-01

    The biological fluidized bed process is a modification of more conventional fixed film processes, such as the trickling filter, in which wastewater is passed upward through a bed of granular support medium, typically sand, at a sufficient velocity to expand or fluidize the medium. The granular medium provides a large surface area for the establishment of a biological film. The fluidized bed process was selected to investigate the treatment of coking plant wastewaters in view of the significant advantages offered in terms of reduced reactor volumes that result from the high biomass concentration maintained on the support medium. The technical feasibility of treating coal distillation condensates was evaluated during a 3-year study at Environment Canada's Wastewater Technology Centre (WTC). The feed to the pilot scale test system consisted of effluent from fixed and free leg ammonia stills at the by-product coke plant of Dofasco Inc. in Hamilton, Ontario. The pilot plant consisted of two fluidized bed reactors in series, coupled to provide carbon oxidation, nitrification and denitrification in the predenitrification operating mode. The anoxic denitrification reactor was 115 mm in diameter and the oxygenic nitrification reactor, 290 mm in diameter. The bed heights and reactor volumes were adjustable by relocation of the position of the sand/biomass wasting valve. The experimental objective of this research was to determine those operating conditions required to maintain stable nitrification and complete denitrification under both steady state and dynamic operating conditions. Details regarding operating, sampling and analytic procedures have been presented elsewhere. A specific operating problem existed relating to the control of the dissolved oxygen concentration in the oxygenic fluidized bed reactor, the solution of which forms the basis of the paper

  2. Ana?lisis te?cnico de un central solar para la produccio?n de energi?a ele?ctrica en el canto?n Santa Isabel de la provincia del Azuay

    OpenAIRE

    Macancela V, Washington; Regalado C., Edmundo; Campoverde A, Freddy; Quizhpi P., Flavio

    2013-01-01

    Al igual que el modelo energe?tico mundial, la matriz ele?ctrica del Ecuador depende en parte de un sistema basado en fuentes de energi?a fo?sil y una fraccio?n del sistema es energi?a renovable, la primera contribuye con la emanacio?n de gases de efecto invernadero. Hoy en di?a el desarrollo e implementacio?n de tecnologi?as de generacio?n ele?ctrica orientadas directamente al cuidado del medio ambiente, se ha tornado sumamente importante. Entre otras razones por la cual se investiga sobr...

  3. Experimental evaluation of the consumption of electrical energy of domestic refrigerators in Mexico; Evaluacion experimental del consumo de energia electrica de refrigeradores domesticos en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Arroyo Cabanas, Fernando Gabriel [Programa de Energia, Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico); Ambriz Garcia, Juan Jose; Paredes Rubio, Hernando Romero [Area de Ingenieria en Recursos Energeticos, Universidad Autonoma Metropolitana, Mexico, D.F. (Mexico)

    2004-06-15

    In this work the experimental methodology developed to carry out tests of the electrical energy of refrigerators consumption as norm NOM-015-ENER-2002 is described. The tests were made in the Laboratory of Controlled Environment of the Iztapalapa Unit of the Universidad Autonoma Metropolitana to a sample of old domestic refrigerators in operation. The results found show that the consumption of electrical energy of refrigerators of more than 10 years of age can be higher than 60% of what a modern refrigerator of high efficiency would consume, or 30% higher if the refrigerator was made between 1997 and 2002. With these results it is sustained, in a more complete way, the evaluation of the saving potential of the national electrical energy by the substitution of old domestic refrigerators by modern, as reported in a previous work. [Spanish] En este trabajo se describe la metodologia experimental desarrollada para efectuar pruebas del consumo de energia electrica a refrigeradores conforme la norma NOM-015-ENER-2002. Las pruebas se realizaron en el Laboratorio de Ambiente Controlado de la Unidad Iztapalapa de la Universidad Autonoma Metropolitana a una muestra de refrigeradores domesticos antiguos en operacion. Los resultados encontrados muestran que el consumo de energia electrica de refrigeradores de mas de 10 anos de antig�edad puede superior al 60% de lo que consumiria un refrigerador moderno de alta eficiencia, o superior en un 30% si el refrigerador fue fabricado entre 1997 y 2002. Con estos resultados se sustenta de manera mas completa la evaluacion del potencial de ahorro de energia electrica nacional por substitucion de refrigeradores domesticos antiguos por modernos reportado en un trabajo anterior.

  4. Demand curves of electric energy in domestic sector in two regions of Mexico; Curvas de demanda de energia electrica en sector domestico de dos regiones de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Maqueda Zamora, Martin Roberto; Sanchez Viveros, Luis Agustin [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2011-07-01

    In this work, is presented the analysis of residential consumption, regarding the temperature of two areas and types of electrical appliances. A shape characteristic of the load of the electrical energy is obtained for two geographical areas in Mexico. The consumption information was obtained from measurements in residential consumers and from the Mexican Utility. It is also shown the demand profile of the main residential appliances, obtained from smart metering equipment to separate the residential users' load profiles. It is shown the effect of the different variables analyzed on the electrical power consumption, mainly the type of equipment, the geographical localization, the weather (temperature, humidity and vegetation type). With the results attained, the definition of effective energy-saving programs and its effectiveness can be obtained. [Spanish] En este trabajo se presenta el analisis del consumo residencial considerando la temperatura de las dos areas y tipos de aparatos electricos. Se obtiene una forma caracteristica de la carga de energia electrica de dos areas geograficas de Mexico. La informacion sobre el consumo se obtuvo de mediciones en consumidores residenciales y de una empresa electrica mexicana. Tambien se muestra el perfil de demanda de los principales aparatos residenciales, derivado de equipos de medicion inteligentes para separar los perfiles de carga de usuarios residenciales. Se muestra el efecto de diferentes variables analizadas en el consumo de energia electrica, principalmente el tipo de equipo, la localizacion geografica, el clima (temperatura, humedad y tipo de vegetacion). Con los resultados alcanzados pueden definirse programas de ahorro de energia efectivos y lograr implantarlos.

  5. Efficient use of electric power in corporative 3M Mexico; Uso eficiente de la energia electrica en el corporativo 3M Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Perez, Alfredo; Quinones Bonilla, Antonio S. [3M Mexico, S.A. de C.V. (Mexico); Bustos Antunez, Jorge I.; Reyes Arce, Manuel [Hines Interests, S.A. de C.V. (Mexico)

    2003-07-01

    It is not enough to count on with the state of the art technology for the daily operation of a building, the challenge is to be able to make a clear analysis and with attainable goals for the optimization of rational use of the electrical energy in the operation of intelligent buildings without affecting the comfort and productivity for users as well as the functionality and profitability for the owner. This went our base to carry out control strategies that helped the efficient use of the electrical energy, obtaining important savings without neglecting the operative part, of services and human within the property. It is thus, that 3M Mexico wanting to reach these purposes, conducted actions to improve the efficiency of the equipment in the following items: electric network, general lighting, air conditioning system, ventilation and extraction, hydropneumatic system, and sumps operation. [Spanish] No basta contar con la tecnologia de punta para la operacion diaria de un edificio, el reto es ser capaces de realizar un analisis claro y con metas alcanzables para la optimizacion de uso racional de la energia electrica en las operaciones de edificios inteligentes sin afectar el confort y productividad para usuarios asi como la funcionalidad y rentabilidad para el propietario. Esta fue nuestra base para llevar a cabo estrategias de control que ayudaron al uso eficiente de la energia electrica, obteniendo ahorros importantes sin descuidar la parte operativa, de servicios y humana dentro de la propiedad. Es asi, que 3M Mexico queriendo alcanzar dichos propositos, realizo acciones para mejorar la eficiencia de los equipos en los siguientes rubros: red electrica, iluminacion general, sistema de aire acondicionado, ventilacion y extraccion, sistema hidroneumatico, y operacion de carcamos.

  6. Methodology for evaluating the grounding system in electrical substations; Metodologia para la evaluacion del sistema de puesta a tierra en subestaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Torrelles Rivas, L.F [Universidad Nacional Experimental Politecnica: Antonio Jose de Sucre (UNEXPO), Guayana, Bolivar (Venezuela)]. E-mail: torrellesluis@gmail.com; Alvarez, P. [Petroleos de Venezuela S.A (PDVSA), Maturin, Monagas (Venezuela)]. E-mail: alvarezph@pdvsa.com

    2013-03-15

    The present work proposes a methodology for evaluating grounding systems in electrical substations from medium and high voltage, in order to diagnose the state of the elements of the grounding system and the corresponding electrical variables. The assessment methodology developed includes a visual inspection phase to the elements of the substation. Then, by performing measurements and data analysis, the electrical continuity between the components of the substation and the mesh ground is verified, the soil resistivity and resistance of the mesh. Also included in the methodology the calculation of the step and touch voltage of the substation, based on the criteria of the International IEEE standards. We study the case of the 115 kV Pirital Substation belonging to PDVSA Oriente Transmission Network. [Spanish] En el presente trabajo se plantea una metodologia para la evaluacion de sistemas de puesta a tierra en subestaciones electricas de media y alta tension, con la finalidad de diagnosticar el estado de los elementos que conforman dicho sistema y las variables electricas correspondientes. La metodologia de evaluacion desarrollada incluye una fase de inspeccion visual de los elementos que conforman la subestacion. Luego, mediante la ejecucion de mediciones y analisis de datos, se verifica la continuidad electrica entre los componentes de la subestacion y la malla de puesta a tierra, la resistividad del suelo y resistencia de la malla. Se incluye tambien en la metodologia el calculo de las tensiones de paso y de toque de la subestacion, segun lo fundamentado en los criterios de los estandares Internacionales IEEE. Se estudia el caso de la Subestacion Pirital 115 kV perteneciente a la Red de Transmision de PDVSA Oriente.

  7. Interconnection of industrial centers with the electric network of the public service; Interconexion de centros industriales con la red electrica del servicio publico

    Energy Technology Data Exchange (ETDEWEB)

    Rosales Sedano, Inocente; Lopez Velazquez, Juan Jose; Garcia Paredes, Job; Robles Pimentel, Edgar [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico); Garcia Alvarez, David; Guzman Camacho, Benigno [Petroleos Mexicanos (Mexico)

    2000-07-01

    The large industrial centers that have continuous production processes and consume high amounts of electrical energy, generally have their own power generation. The petrochemical complexes, the paper and steel factories and the sugar mills are examples of this type of centers. On the other hand, the new regulation for the generation of electrical energy that allows to the electrical energy interchange between private companies and the public network, has originated the necessity of connecting systems that formerly operated isolated. Since the original design of the isolated electrical systems was to operate in an independent form, making the interconnection can generate technical problems that must be analyzed and solved. In this paper, some experiences related with the behavior of electrical equipment when connected to operate with the public network, are presented. [Spanish] Los grandes centros industriales que tienen procesos de produccion continua y consumen altas cantidades de energia electrica, generalmente cuentan con generacion propia. Los complejos petroquimicos, las fabricas de papel y acero y los ingenios azucareros son ejemplos de este tipo de centros. Por otro lado, la nueva reglamentacion de generacion de energia electrica que permite el intercambio de energia electrica entre las companias privadas y la red publica, ha originado la necesidad de conectar sistemas que antes operaban aislados. Debido a que el diseno original de los sistemas electricos aislados fue trabajar en forma independiente, el realizar la interconexion puede generar problemas tecnicos que tienen que analizarse y resolverse. En este articulo, se presentan algunas experiencias relacionadas con el comportamiento del equipo electrico al operar conectado con la red publica.

  8. The effects of agglomeration/defluidization on emission of heavy metals for various fluidized parameters in fluidized-bed incineration

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Chiou-Liang; Tsai, Ming-Chih; Chang, Chih-Hung [Department of Civil and Environmental Engineering, National University of Kaohsiung, Kaohsiung, 811 (China)

    2010-01-15

    The agglomeration/defluidization may be produced to generate the secondary pollutant during incineration. However, the effects of agglomeration/defluidization on heavy metal distribution have rarely been examined. Therefore, the effects of the agglomeration/defluidization process on heavy metal emission in flue gas are studied. The artificial waste is employed to simulate municipal waste and to form agglomerates, which contain alkali metals, earth alkali metals, a mixture of metals (Pb, Cr and Cd) and sawdust. The fluidized parameters (including gas velocity, sand particle size and static bed height) are varied to determine their influences on heavy metal emission. The results indicate that addition of Na increases the risk of agglomeration/defluidization, but the emission concentration of heavy metals decreases during agglomeration/defluidization. The heavy metals may react with Na to form the eutectics or are covered and adhered by the liquid-phase eutectics of Na to stay in sand particle and lead to a decrease in the emission of heavy metals. The system was operated at a low gas velocity that not only easily resulted in agglomeration/defluidization but also increased the emission concentration of heavy metals. Large particles (920 {mu}m), which have a poor fluidized quality, had the highest emission concentration. Small particles (645 {mu}m) were uniformly fluidized to enhance the fluidization quality and to decrease the emission concentration. Additionally, adding Ca did not decrease the heavy metal emission concentration, but maintained the fluidization during eutectic accumulation. The Ca prevented the sand bed from quickly achieving defluidization and prolonged the increased emission of heavy metals after defluidization. (author)

  9. The Spanish energetic mix; prevision and historic evolution of the electric production structure; El mix energetico espanol; evolucion historica y prevista de la estructura de produccion electrica

    Energy Technology Data Exchange (ETDEWEB)

    Revuelta, J.; Lopez Sanz, R.

    2010-07-01

    This article describes the past and forecasted evolution of the electric production of the Spanish system (excluding the Spanish isolated systems), according to the records of the System Operator, Red Electrica de Espana, and the studies of its Network Planning department. The behaviour of the demand is analysed, as well as the evolution of the generation mix. The article expose the main recent changes the sector has undergone and points out the main future challenge it will face regarding the forecasted evolution of the demand, the integration of renewable energy sources, and the energy objectives established at European and national level. (Author)

  10. Investigaciones de las representaciones sociales del medio ambiente en Brasil y México

    Directory of Open Access Journals (Sweden)

    Calixto Flores, Raúl

    2013-01-01

    Full Text Available Resumen: En este artículo se describen algunas investigaciones sobre las representaciones sociales del medio ambiente en Brasil y en México, con el objetivo de observar las implicaciones de estos estudios para la educación ambiental; destaca el hecho de que sus resultados son coincidentes, a pesar de que sean distintas culturas y lenguajes, así como diferentes grupos de población y niveles educativos. La exploración de las investigaciones muestra la pertinencia del empleo de la teoría de las representaciones sociales, para identificar, comprender y explicar el pensamiento social en el campo de la educación ambiental. Los autores más citados en las investigaciones anteriormente referidas son Denise Jodelet, Serge Moscovici, Marcos Reigota y Jean Claude Abric. Durante esta breve revisión, se observa el predominio de las investigaciones realizadas con estudiantes, la mayoría utiliza una metodología cualitativa y un enfoque interpretativo. En las diversas investigaciones analizadas, sobre las representaciones del medio ambiente, se evidencia su importancia para comprender la práctica de la educación ambiental. Por ende, para la educación ambiental resulta fundamental comprender las formas en que se establecen las representaciones sociales, en la desconstrucción-construcción de los elementos que forman su pensamiento cotidiano. Considerando los resultados de las investigaciones revisadas, se puede afirmar que el medio ambiente es un objeto social complejo, cultural y contextualmente determinado. Abstract: In this article we describe some researches on social representations of the environment in Brazil and Mexico, with the aim to observe the implications of the studies for the environmental education; highlights the fact that their results are coincident, although they are different cultures and languages, and different population groups and educational levels. The exploration of the research shows the relevance of using the theory

  11. ENSAYO: RELACIONES DE GÉNERO EN INVESTIGACIONES BASADAS EN EXPERIENCIAS DE HISTORIA ORAL

    Directory of Open Access Journals (Sweden)

    Olga Cabrera García

    2008-08-01

    Full Text Available Este ensayo se propone analizar algunas cuestiones acerca de la perspectiva multidisciplinar en la metodología de la historia oral. Las investigaciones de historia oral tienen algunas características que le dan su especificidad pero, el artículo se concentra sobre dos de ellas: la entrevista y la construcción del documento oral. Se presentan algunas experiencias de ambas etapas de la investigación aunque el énfasis recae sobre el segundo aspecto. Se estudia la vida cotidiana así como la memoria, vinculadas al tiempo, con el propósito de comprender la historia oral.

  12. ENSAYO: RELACIONES DE GÉNERO EN INVESTIGACIONES BASADAS EN EXPERIENCIAS DE HISTORIA ORAL

    OpenAIRE

    Olga Cabrera García

    2008-01-01

    Este ensayo se propone analizar algunas cuestiones acerca de la perspectiva multidisciplinar en la metodología de la historia oral. Las investigaciones de historia oral tienen algunas características que le dan su especificidad pero, el artículo se concentra sobre dos de ellas: la entrevista y la construcción del documento oral. Se presentan algunas experiencias de ambas etapas de la investigación aunque el énfasis recae sobre el segundo aspecto. Se estudia la vida cotidiana así como la memor...

  13. EL CRITERIO DE ESPECIALISTAS Y EL EXPERIMENTO EN LAS INVESTIGACIONES EDUCACIONALES

    Directory of Open Access Journals (Sweden)

    Roberto Valledor Estevill

    2010-03-01

    Full Text Available En este artículo se describen dos métodos a emplear en las investigaciones educacionales: el criterio de especialistas para la validación y perfeccionamiento de propuestas pedagógicas antes de su introducción en la práctica escolar, y el experimento como criterio de la verdad y validación definitiva de los resultados. Mediante ejemplos se explica cómo el investigador puede diseñar el empleo de estos métodos.

  14. Red Electrica de Espana S.A.. Instrument of regulation and liberalization of the Spanish electricity market (1944-2004)

    International Nuclear Information System (INIS)

    Garrues-Irurzun, Josean; Lopez-Garcia, Santiago

    2009-01-01

    To understand the regulation system of the Spanish electricity market it is first necessary to understand on the one hand the system of tariffs and prices, and on the other the organization of the market for high voltage distribution. This article is concerned with this second aspect and traces its history from 1944, this is because before that date it was not possible to speak of a truly national market, but rather only of regional monopolies. In the 1940s, with Franco's new political regime, and the development of the Spanish electricity sector, it became necessary to completely rethink business strategies in relation to competition and cooperation, as well as the regulatory function of the state. In the 1950s, the main feature of the sector was the system of business self-regulation permitted by the state. Throughout the remaining years of Franco's government state intervention was particularly focussed on the subject of tariffs, but with the onset of democracy the state was to involve itself in the transmission network as well. A debate began as to whether it should be run by a private or public operator. In this dispute were ranged, on the one hand, the economic policy concepts of the major parties (PSOE and PP), and against them the strategic interests of the companies. Although the high voltage transmission network was nationalized by the state in the mid-1980s, establishing a 'traditional' model of regulation, the 1990s saw the triumph of a market-based regulation, strongly influenced by the dominant ideas in the European Union, which has converted Red Electrica into a private company. Currently the TSO (Transmission System Operators) model has been extended to Portugal and has entered into competition-cooperation with the other models of the European electricity market. (author)

  15. Importance of the validation of saving technologies of electric power; Importancia de la validacion de tecnologias ahorradoras de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Valer Negrete, Adrian [Programa de Ahorro de Energia del Sector Electrico (PAESE), Comision Federal de Electricidad (Mexico)

    2003-07-01

    Within the Programs of Energy Saving it is fundamental the search and application of new technologies, with which this saving can be obtained, selected with base in their technical characteristics that allow to reduce to the consumptions and demands of power, without damaging the electric networks nor the transformers of the Comision Federal de Electricidad. It is important that the investments which are made count on attractive periods of capital recovery, in comparison with the useful life of the product, reason why the knowledge and price of the new technologies will be parameters to consider in an important manner, creating the need of conducting tests that verify the veracity of the information of the supplier, resulting in certain cases, the change of design of these technologies, so that thus they fulfill the engaged characteristics. This paper indicates the characteristics that the new saving technologies of electrical energy must fulfill and the tests and parameters to consider their evaluation. [Spanish] Dentro de los Programas de Ahorro de Energia es fundamental la busqueda y aplicacion de nuevas tecnologias, con las que se pueda obtener dicho ahorro, seleccionadas con base en sus caracteristicas tecnicas que permitan reducir los consumos y demandas de potencia, sin danar las redes ni transformadores de la Comision Federal de Electricidad. Es importante que las inversiones que se realicen cuenten con periodos de recuperacion de capital atractivos, comparados con la vida util del producto, por lo que el conocimiento y precio de las nuevas tecnologias seran parametros a considerar de manera importante, creandose la necesidad de realizar pruebas que verifiquen la veracidad de la informacion del proveedor, resultando en determinados casos, el cambio de diseno de dichas tecnologias, para que asi cumplan las caracteristicas prometidas. Este trabajo indica las caracteristicas que deben cumplir las nuevas tecnologias ahorradoras de energia electrica y las

  16. Design and simulation of a circulating fluidized bed to clean the products of biomass gasification

    Energy Technology Data Exchange (ETDEWEB)

    Uchoa Neto, Moises; Carvalho, Yuri de Araujo [Dept. de Engenharia Mecanica. Faculdade de Tecnologia. Universidade de Brasilia, DF (Brazil); Oliveira, Taygoara Felamingo de; Barcelos, Manuel [Faculdade do Gama. Universidade de Brasilia, Gama, DF (Brazil)], e-mail: taygoara@unb.br

    2010-07-01

    The main goal of this work is to design a workbench circulating fluidized bed to study the cracking of tar in gases from the processes of biomass gasification. For this, a design methodology based on analytical results and empirical correlations for fluidized beds was employed. In parallel, a numerical code of open source technology (MFIX) for the solution of the transport equations of the multiphase flow in the column of a fluidized bed was used to give support to the choice of the design elements. The whole project of the workbench fluidized bed was completely developed, whose operation parameters such as bed geometry, gas velocity, circulating ratio and void fraction characterize a fast fluidization process. A preliminary mesh convergence study was executed with the numerical tool, that was validated comparing with analytical results. Among the most important results, the code computed the predicted value for the minimum fluidization. (author)

  17. Sodium and steam leak simulation studies for fluidized bed steam generators

    International Nuclear Information System (INIS)

    Keeton, A.R.; Vaux, W.G.; Lee, P.K.; Witkowski, R.E.

    1976-01-01

    An experimental program is described which was conducted to study the effects of sodium or steam leaking into an operating fluidized bed of metal or ceramic particles at 680 to 800 0 K. This effort was part of the early development studies for a fluidized-bed steam generator concept using helium as the fluidizing gas. Test results indicated that steam and small sodium leaks had no effect on the quality of fluidization, heat transfer coefficient, temperature distribution, or fluidizing gas pressure drop across the bed. Large sodium leaks, however, immediately upset the operation of the fluidized bed. Both steam and sodium leaks were detected positively and rapidly at an early stage of a leak by instruments specifically selected to accomplish this

  18. Minimum and Full Fluidization Velocity for Alumina Used in the Aluminum Smelter

    Directory of Open Access Journals (Sweden)

    Paulo Douglas S. de Vasconcelos

    2011-11-01

    Full Text Available Fluidization is an engineering unit operation that occurs when a fluid (liquid or gas ascends through a bed of particles, and these particles get a velocity of minimum fluidization enough to stay in suspension, but without carrying them in the ascending flow. As from this moment the powder behaves as liquid at boiling point, hence the term “fluidization”. This operation is widely used in the aluminum smelter processes, for gas dry scrubbing (mass transfer and in a modern plant for continuous alumina pot feeding (particles’ momentum transfer. The understanding of the alumina fluoride rheology is of vital importance in the design of fluidized beds for gas treatment and fluidized pipelines for pot feeding. This paper shows the results of the experimental and theoretical values of the minimum and full fluidization velocities for the alumina fluoride used to project the state of the art round non‐metallic air‐fluidized conveyor of multiples outlets.

  19. Supervisory fussy control for an electric generating hybrid system; Control supervisorio difuso para un sistema hibrido de generacion electrica

    Energy Technology Data Exchange (ETDEWEB)

    Lagunas Mendoza, Javier

    2004-11-15

    the fuzzy supervisory controller were compared with a conventional controller. The results shows that the supervisory controller fulfills the three main objectives of the system operation: I) to reduce the fuel consumption of the back-up system, II) to reduce the depth of the discharge of the battery bank, and III) to keep fully charged the battery bank as much as possible in order to make a better use of the available free renewable energy sources. [Spanish] En este trabajo se presenta el desarrollo de un controlador supervisorio difuso para un sistema hibrido de generacion electrica (SHGE). En este trabajo se definio la configuracion y los elementos que componen el SHGE a utilizar, producto de la revision de configuraciones de sistemas hibridos propuestas actualmente. La configuracion del SHGE incluye: arreglos fotovoltaicos y aerogeneradores como fuentes de generacion renovable, una maquina de combustion interna como sistema de respaldo, un banco de baterias como medio de almacenamiento de energia, cargas electricas en corriente alterna y un inversor CD/CA para poder alimentarlas. Tambien a partir de la configuracion propuesta se buscaron y seleccionaron los modelos matematicos de los diferentes elementos del sistema. Se llevo a cabo la validacion de los modelos a traves de la comparacion de la salida contra datos reales obtenidos en un SHGE instalado en Pachuca. Con los modelos se llevo a cabo el desarrollo de un programa de simulacion para un SHGE en Matlab. Se determino la funcion principal del controlador supervisorio dentro del SHGE. La funcion es satisfacer el o los objetivos de operacion del sistema. La filosofia de operacion del controlador supervisorio se definio a partir de la configuracion electrica propuesta y de los objetivos de operacion del sistema. Por lo que respecta al desarrollo del controlador supervisorio, se llevo a cabo una revision de los controladores supervisorios actuales que utilizan alguna tecnica de control inteligente. A partir de

  20. Study of standard tablet formulation based on fluidized-bed granulation.

    Science.gov (United States)

    Sunada, H; Hasegawa, M; Makino, T; Sakamoto, H; Fujita, K; Tanino, T; Kokubo, H; Kawaguchi, T

    1998-03-01

    In this study, acetaminophen, ascorbic acid, and ethenzamide were selected as model drugs for tableting granules. Agitation and fluidized-bed granulation were carried out at three drug contents of 30, 50, and 70%. Compared with agitation granulation, granules made by fluidized-bed granulation showed superior compressibility with wide formulation allowance for drug type and amount. Fluidized-bed granulation resulted in less granule hardness and greater plastic deformability. The granules had considerable compactness and for tablets containing 70% ethenzamide, prolonged disintegration and dissolution times were noted. These are typical features of granules produced by fluidized-bed granulation.

  1. Application and Discussion of Dual Fluidized Bed Reactor in Biomass Energy Utilization

    Science.gov (United States)

    Guan, Haibin; Fan, Xiaoxu; Zhao, Baofeng; Yang, Liguo; Sun, Rongfeng

    2018-01-01

    As an important clean and renewable energy, biomass has a broad market prospect. The dual fluidized bed is widely used in biomass gasification technology, and has become an important way of biomass high-value utilization. This paper describes the basic principle of dual fluidized bed gasification, from the gas composition, tar content and thermal efficiency of the system point of view, analyzes and summarizes several typical dual fluidized bed biomass gasification technologies, points out the existence of gas mixing, the external heat source, catalyst development problems on gas. Finally, it is clear that the gasification of biomass in dual fluidized bed is of great industrial application and development prospect.

  2. Importance of fragmentation on the steady state combustion of wood char in a bubbling fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Pinho, Carlos [Universidade do Porto (CEFT/FEUP), Porto (Portugal). Faculdade de Engenharia. Centro de Estudos de Fenomenos de Transporte], E-mail: ctp@fe.up.pt

    2010-07-01

    A simple mathematical model for the analysis of the steady state behavior of a bubbling fluidized bed burner is presented, with the main intention of evaluating the importance of the primary fragmentation of fuel particles on the performance of this type of burners. This model has pedagogical advantages because of its simplicity and easiness of application to the analysis of realistic situations. The model is based upon the classical models used for the study of batch combustion processes in fluidized bed reactors. Experimental data from studies of fluidized bed combustion of portuguese vegetable chars are used to support the analysis of the performance of a 1 m diameter fluidized bed combustor. (author)

  3. Analysis of the pressure fluctuations in binary solids circulating fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Chen Yongguo [School of Mechanical and Power Engineering, Shanghai JiaoTong University, Dongchuan Road 800, Shanghai 200240 (China)]. E-mail: yongguo_chen@hotmail.com; Tian Ziping [School of Mechanical and Power Engineering, Shanghai JiaoTong University, Dongchuan Road 800, Shanghai 200240 (China); Miao Zhengqing [School of Mechanical and Power Engineering, Shanghai JiaoTong University, Dongchuan Road 800, Shanghai 200240 (China)

    2006-03-15

    Pressure fluctuations are often selected to analyze the dynamic changes in the fluidized bed. Many researchers in the field of fluidization have adopted many methods to analyze the pressure signals in fluidized beds, such as statistical analysis (in time domain), frequency analysis (in frequency domain) and non-linear analysis (such as chaotic method). There are many literatures concentrated on statistical analysis in the fluidization field since this method can display the distribution density of the pressure fluctuations. In this study, the pressure fluctuations on the bed wall at different bed heights in the cold two dimensional (2-D) circulating fluidized bed (200 x 30 x 1200 mm{sup 3}) were sampled. The colophony, millet and 20% millet plus 80% colophony were selected as bed materials. The pressure signals were analyzed by means of statistical methods. The correlation equations between the pressure signals and fluidization parameters were obtained under different operational conditions. Finally, comparisons between the single solid and binary solids 2-D circulating fluidized beds were investigated deeply. Two parameters, K {sub 1} (=0.54(u - u {sub mf}){sup 0.4} h {sup 0.8}/g {sup 0.2}) and K {sub 2} (={sigma} {sub b}/({rho} {sub s} g(1 - {epsilon} {sub mf}))), were selected to characterize the fluidization mechanism. It was found that the relationships between K {sub 2} and K {sub 1} among the single solid and binary solids circulating fluidized beds vary a great deal.

  4. Characterization of products from fluidized-bed combustion of coal.

    Science.gov (United States)

    Bednarik, V; Vondruska, M; Sild, M; Vondruskova, E

    2000-11-01

    The technology of fluidized-bed combustion (FBC) of coal generates byproducts that have a series of unique characteristics and potential uses in technological practice. In this study, the products of fluidized-bed combustion (FBC-P) of coal derived from Moravian heat stations, a.s. Zlin, Cinergy Global Resources, Czech Republic, were characterized. Particular attention was paid to determining the chemical composition of FBC-P, the content of polycyclic aromatic hydrocarbons (PAHs) and toxic metals in the water leachates of these FBC-P, the content of unburned carbon, the capability of FBC-P to solidify with water and form a solid matrix, and the method for discovering optimum mixing water content for FBC-P solidification. The results suggest that one of the qualitatively more important means of utilizing FBC-P could be their application during solidification/stabilization (S/S) of wastes, particularly wastewater treatment sludges.

  5. Pulverized coal vs. circulating fluidized bed: An economic comparison

    International Nuclear Information System (INIS)

    Johns, R.F.

    1991-01-01

    As the power industry looks to the 1990s for expanded steam generation capacity, boiler owners will continue on their long-standing assignment to evaluate and select the best, lowest cost alternative to meet their energy needs. For coal-fired plants, this evaluation process includes pulverized coal-fired boilers (PC) and circulating fluidized bed boilers (CFB). The cost difference between these products is site specific and depends on several variables, including: Boiler size, pressure, and temperature; Operating variables, such as the cost for fuel, auxiliary power, SO 2 reagent, and ash disposal; Capital cost; and Financial variables, such as evaluation period and interest rate. This paper provides a technical and economic comparison between a pulverized coal-fired boiler and circulating fluidized bed boiler

  6. Nitrogen Chemistry in Fluidized Bed Combustion of Coal

    DEFF Research Database (Denmark)

    Jensen, Anker Degn

    The present Ph.D thesis describes an experimental and theoretical investigation of the formation and destruction of nitrogen oxides (NOx and N2O) in fluidized bed combustion (FBC) of coal. A review of the current knowledge of nitrogen chemistry in FBC is presented. The review covers both laboratory...... for the emission of NOx from FBC has been developed as part of a JOULE project. The model is based on the two-phase theory of fluidization for the bed with a Kunii-Levenspiel type freeboard model and includes submodels for coal devolatilization, combustion of volatiles and char and a detailed model of NO formation...... and reduction by homogeneous and heterogeneous reactions. The data for the estimation of kinetics of the heterogeneous reactions were measured by one of the partners in the project for char and bed material sampled from a pressurized FBC pilot plant burning Kiveton Park coal. Experimental data from the pilot...

  7. Carbon Shale Combustion in the Fluidized Bed Reactor

    Directory of Open Access Journals (Sweden)

    Olek Małgorzata

    2014-06-01

    Full Text Available The purpose of this article is to present the possibilities of coal shale combustion in furnaces with bubbling fluidized bed. Coal shale can be autothermally combusted in the fluidized bed, despite the low calorie value and high ash content of fuel. Established concentrations of CO (500 ppm and VOC (30 mg/m3 have indicated a high conversion degree of combustible material during combustion process. Average concentrations of SO2 and NOx in the flue gas were higher than this received from the combustion of high quality hard coal, 600 ppm and 500 ppm, respectively. Optional reduction of SO2 and NOx emission may require the installation of flue gas desulphurization and de-NOx systems.

  8. Combustion of Jordanian oil shale using circulating fluidized bed

    International Nuclear Information System (INIS)

    Hamdan, M.; Al-Azzam, S.

    1998-11-01

    this study re[resents design and manufacturing of a lab-scale circulating fluidized bed (C.F.B) to burn low grade fuel such as Jordanian oil shale. Hydrodynamic properties of C.F.B. were studied like minimum fluidization velocity, circulation flux and carryover rate. a hot run was firstly conducted by the combustion of L.P.G. to start up the combustion process. It proceeds until reaching the minimum burning temperature of oil shale particles, at which time the LPG supply was gradually reduced and oil shale feeding started. soon after reaching a self sustainable condition of oil shale particles, the LPG supply was cut off. The main combustion variables were investigated such as air to fuel ratios, temperature profiles across the bed, exhaust gas analysis and combustion efficiency. a combustion intensity of 859 kg/hr.m 2 and combustion efficiency of 96% were achieved. (authors). 19 refs., 9 tab., 18 fig

  9. A computational fluid dynamic model for fluidized bed heat transfer

    International Nuclear Information System (INIS)

    Yusuf, R.; Melaaen, M.C.; Mathiesen, V.

    2005-01-01

    The objective of this work is to study heat transfer from a heated wall in a gas fluidized bed using the computational fluid dynamic (CFD) approach. An Eulerian-Eulerian simulation of a two dimensional bubbling bed at ambient conditions with a heated wall is carried out on the in-house code FLOTRACS-MP-3D. An empirical as well as a mechanistic model for solid phase thermal conductivity is tested. Effect of operating parameters like velocity and particle size are also investigated. The fluid dynamic model is able to predict the qualitative trends for the influence of operating parameters as well as high heat transfer coefficients observed in gas fluidized beds. (author)

  10. Combustion of refuse derived fuel in a fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Piao, Guilin; Aono, Shigeru; Mori, Shigekatsu; Deguchi, Seiichi; Fujima, Yukihisa [Nagoya Univ. (Japan); Kondoh, Motohiro; Yamaguchi, Masataka [Toyota Motor Corp. (Japan). Plant Engineering Dept.

    1998-12-31

    Power generation from Refuse Derived Fuel (RDF) is an attractive utilization technology of municipal solid waste. To explain the behavior of RDF-fired fluidized bed incinerator, the commercial size RDF was continuously burnt in a 30 x 30 cm bubbling type fluidized-bed combustor. It was found that 12 kg/h of RDF feed rate was too high feed for this test unit and the Co level was higher than 500 ppm. However, 10 kg/h of RDF was a proper feed rate and the Co level was kept under 150 ppm. Secondary air injection and changing air ratio from the pipe grid were effective for the complete combustion of RDE. It was also found that HCl concentration in flue gas was controlled by the calcium component contained in RDF and its level was decreased with decreasing the combustor temperature.

  11. Las investigaciones recientes sobre la migración laboral femenina internacional

    Directory of Open Access Journals (Sweden)

    María J. Rodríguez Shadow

    2008-01-01

    Full Text Available El objetivo de este artículo es analizar las investigaciones que se han llevado a cabo, desde diversas disciplinas, sobre la migración laboral femenina internacional. Los estudios que se examinan han sido elaborados desde diversos campos disciplinarios: la antropología, la historia y la sociología, empleando diversas metodologías: trabajo etnográfico, encuestas, entrevistas, historias de vida, censos, entre otros. Las regiones bajo estudio incluyen Asia, Europa, India, África y los Estados Unidos. La conclusión que se desprende de este conjunto de investigaciones es que la integración de la categoría analítica de género resulta indispensable, toda vez que las mujeres y sus desplazamientos laborales han sido omitidas de los estudios de migración internacional por suponerse, erróneamente, que las mujeres no migran. En la literatura analizada se discuten las motivaciones femeninas para migrar y la forma en la que impacta la migración en la transformación de las relaciones de género en las sociedades estudiadas.

  12. TRANSFORMACIONES EN LAS INVESTIGACIONES ANTROPOLÓGICAS sobre naturaleza, ecología y medio ambiente

    Directory of Open Access Journals (Sweden)

    ASTRID ULLOA

    2001-01-01

    Full Text Available EN LAS INVESTIGACIONES ANTROPOLÓGICAS HA HABIDO UN LARGO PROCESO DE TRANSformación e interacción de la noción moderna de la naturaleza con nociones híbridas de cuasi-objetos y cuasi-humanos, así como la transformación de las concepciones de la naturaleza de una entidad apolítica a construcciones sociales con implicaciones políticas. Para analizar estos procesos, este texto presenta una revisión teórica de los cambios que se han dado en las categorías e investigaciones antropológicas sobre naturaleza, ecología y medio ambiente. Se destacan dos tendencias: la primera, ligada al replanteamiento de la dicotomía naturaleza/cultura a la luz de los conocimientos locales. La segunda, relacionada con los aportes de la ecología política, enfatizando el papel de los diferentes actores dentro de los discursos ambientales. Finalmente, se contextualizan las perspectivas de investigación sobre naturaleza, ecología y medio ambiente en América latina y en Colombia.

  13. Research and service capabilities of the National Nuclear Forensic Research Laboratory; Capacidades de investigacion y servicio del Laboratorio Nacional de Investigacion en Forense Nuclear, Lanafonu

    Energy Technology Data Exchange (ETDEWEB)

    Romero G, E. T.; Hernandez M, H.; Flores C, J.; Paredes G, L. C., E-mail: elizabeth.romero@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2016-09-15

    According to the recommendations of the International Atomic Energy Agency, Mexico is taking steps to combat illicit trafficking in nuclear material. The creation of a National Nuclear Forensic Research Laboratory (Lanafonu, acronym in Spanish) has been assigned to the Instituto Nacional de Investigaciones Nucleares (ININ, Mexico) in 2014. The objectives of this Laboratory are: to combat illicit trafficking in nuclear materials, to optimize scientific processes and techniques used to analyze nuclear materials (orphans or radioactive sources), environmental and potential biological sources as a result of the handling, transport and final storage. At present, the Lanafonu facilities are focused on the optimization of emergency and routine protocols for measuring radioisotopes in environmental and biological samples using inductive coupling mass spectrometer with magnetic sector. The main activities are: i) optimization of the methods for measuring the isotopes of Pu by alpha-spectrometry, Icp-SFMS and AMS (accelerator mass spectrometry), ii) development or radiochemical methods for routine situations and nuclear emergencies, iii) participation in the scientific technical commission on nuclear forensic science, iv) participation in international intercomparison exercises to optimize and validate methods, and v) consolidation of Lanafonu in Mexico and the IAEA. (Author)

  14. Biological reduction of nitrate wastewater using fluidized-bed bioreactors

    International Nuclear Information System (INIS)

    Walker, J.F. Jr.; Hancher, C.W.; Patton, B.D.; Kowalchuk, M.

    1981-01-01

    There are a number of nitrate-containing wastewater sources, as concentrated as 30 wt % NO 3 - and as large as 2000 m 3 /d, in the nuclear fuel cycle as well as in many commercial processes such as fertilizer production, paper manufacturing, and metal finishing. These nitrate-containing wastewater sources can be successfully biologically denitrified to meet discharge standards in the range of 10 to 20 gN(NO 3 - )/m 3 by the use of a fluidized-bed bioreactor. The major strain of denitrification bacteria is Pseudomonas which was derived from garden soil. In the fluidized-bed bioreactor the bacteria are allowed to attach to 0.25 to 0.50-mm-diam coal particles, which are fluidized by the upward flow of influent wastewater. Maintaining the bacteria-to-coal weight ratio at approximately 1:10 results in a bioreactor bacteria loading of greater than 20,000 g/m 3 . A description is given of the results of two biodenitrification R and D pilot plant programs based on the use of fluidized bioreactors capable of operating at nitrate levels up to 7000 g/m 3 and achieving denitrification rates as high as 80 gN(NO 3 - )/d per liter of empty bioreactor volume. The first of these pilot plant programs consisted of two 0.2-m-diam bioreactors, each with a height of 6.3 m and a volume of 208 liters, operating in series. The second pilot plant was used to determine the diameter dependence of the reactors by using a 0.5-m-diam reactor with a height of 6.3 m and a volume of 1200 liters. These pilot plants operated for a period of six months and two months respectively, while using both a synthetic waste and the actual waste from a gaseous diffusion plant operated by Goodyear Atomic Corporation

  15. The grinding of uranium dioxide from fluidized beds

    International Nuclear Information System (INIS)

    Alonso Folgueras, J. A.

    1974-01-01

    This work deals with the UO 2 vibratory grinding, the UO 2 obtained from fluidized beds. In this study the grinding time has been correlated with surface area, stoichiometry, granulometry and grinded product contamination. The efficiency losses in the grinding of moisten UO 2 are outlined. Finally it is made a brief study of the granulate obtained from the grinded UO 2 as well as the green pellets resulting from it, taking into consideration the dispersion of its density and height. (Author)

  16. NUCLA Circulating Atmospheric Fluidized Bed Demonstration Project. 1990 Annual report

    Energy Technology Data Exchange (ETDEWEB)

    1992-02-01

    The objective of this DOE Cooperative Agreement is to conduct a cost-shared clean coal technology project to demonstrate the feasibility of circulating fluidized bed combustion technology and to evaluate economic, environmental, and operational benefits of CFB steam generators on a utility scale. At the conclusion of the Phase 2 program, testing related to satisfying these objectives was completed. Data analysis and reporting are scheduled for completion by October 1991. (VC)

  17. Fluidized bed reactor for working up carbon coated particles

    International Nuclear Information System (INIS)

    Marschollek, M.; Simon, W.; Walter, C.

    1981-01-01

    A fluidized bed reactor is described for working up carbon coated particles, particularly nuclear fuel particles or fertile material particles consisting essentially of a cylindrical portion connected to a conical portion. Gas supply pipes, gas distribution space and gas distribution heads are provided within the conical reactor lower portion, the gas distribution members being arranged in at least two superimposed planes and distributed symmetrically over the cross-section of the reactor

  18. Gasification of wood in a fluidized bed reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sousa, L.C. de; Marti, T.; Frankenhaeuser, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-06-01

    A first series of gasification experiments with our fluidized bed gasifier was performed using clean sawdust as fuel. The installation and the analytical systems were tested in a parametric study in which gasification temperature and equivalence ratio were varied. The data acquired will serve to establish the differences between the gasification of clean wood and the gasification of Altholz (scrapwood) and wood/plastics mixtures. (author) 1 fig., 3 tabs., 5 refs.

  19. Spectral methods applied to fluidized bed combustors. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Brown, R.C.; Christofides, N.J.; Junk, K.W.; Raines, T.S.; Thiede, T.D.

    1996-08-01

    The objective of this project was to develop methods for characterizing fuels and sorbents from time-series data obtained during transient operation of fluidized bed boilers. These methods aimed at determining time constants for devolatilization and char burnout using carbon dioxide (CO{sub 2}) profiles and from time constants for the calcination and sulfation processes using CO{sub 2} and sulfur dioxide (SO{sub 2}) profiles.

  20. Distributor effects near the bottom region of turbulent fluidized beds

    OpenAIRE

    Sobrino Fernández, Celia; Ellis, Noko; Vega Blázquez, Mercedes de

    2009-01-01

    The distributor plate effects on the hydrodynamic characteristics of turbulent fluidized beds are investigated by obtaining measurements of pressure and radial voidage profiles in a column diameter of 0.29 m with Group A particles using bubble bubble-cap or perforated plate distributors. Distributor pressure drop measurements between the two distributors are compared with the theoretical estimations while the influence of the mass inventory is studied. Comparison is established fo...

  1. On the solid stress in a fluidized bed

    International Nuclear Information System (INIS)

    Qassim, R.Y.; Souza, R. de.

    1980-09-01

    The existence of solid stress in an incipiently gas-fluidized bed is shown by experimental measurement. This stress is shown to have two components: an isotropic pressure and an extra stress which depends on the relative velocity between fluid and solid. Both the solid pressure and the solid extra stress component are found to be of the same order of magnitude as the fluid pressure. (Author) [pt

  2. Strategies to optimize the electric energy use in non-residential buildings; Estrategias para eficientizar el uso de la energia electrica en edificios no residenciales

    Energy Technology Data Exchange (ETDEWEB)

    Castro Flores, J.; Morillon Galvez, D. [Comision Nacional para el Ahorro de Energia, Mexico, D. F. (Mexico)

    1995-12-31

    This paper presents the problems identified in non-residential buildings, where the inadequate use of energy is mainly shown in three points: inadequate technology and maintenance, wrong use and wrong habits in the energy use. The consequences of this situation in the ecological, politic and social environment were analyzed. In base of the problems detected the following strategies are proposed: An adequate project and design, retrofit, maintenance and users awareness for the rational energy use. The economic evaluation performed for the implementation of these strategies shows a significant saving potential of the electric power, with measures of null and low investment. [Espanol] Se presenta la problematica identificada en edificios no residenciales; donde el uso inadecuado de la energia electrica se manifiesta principalmente en tres puntos: tecnologia y mantenimiento inadecuados, y mal uso y costumbres de la energia. Se analizo las consecuencias de esta situacion en el ambito ecologico, economico, politico y social. Con base a la problematica se proponen las siguientes estrategias: un adecuado proyecto y diseno, retrofit, mantenimiento y concientizacion del usuario para el uso racional de la energia. La evaluacion economica realizada para implantar estas estrategias muestra un significativo potencial de ahorro de energia electrica, con medidas de nula y baja inversion.

  3. Energy saving in buildings through the elimination of typical problems; Ahorro de energia electrica en edificios a traves de la eliminacion de problemas tipicos

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez Rivero, Alex G. [Genertek, S. A. de C. V., Mexico, D. F. (Mexico)

    1993-12-31

    The enormous electric energy consumption in buildings represents an important area of saving opportunities. The design of installations without advanced technical illumination criteria, the absence of standardization over energy efficiency, the lack of observation of the existing standards and guides, the continuous load growth in existing installations and the lack of appropriate maintenance, are some of the causes of the inefficient use of electric energy in buildings. Although the problems, and consequently the solutions, are exclusive for each unit, some of the former are frequently repeated. In this paper the problems found along more than 40 audits conducted in large buildings of different types in Mexico city are commented. [Espanol] El enorme consumo de energia electrica en edificios representa una importante area de oportunidad para ahorro. El diseno de instalaciones sin criterios luminotecnicos avanzados, la ausencia de normalizacion sobre eficiencia energetica, la falta de observancia de las normas y recomendaciones vigentes, el continuo crecimiento de carga en instalaciones existentes y la falta de mantenimiento adecuado son algunas de las causas del uso ineficiente de la energia electrica en inmuebles. Aunque los problemas y por tanto las soluciones son particulares para cada unidad, algunos de los primeros se repiten frecuentemente. En este trabajo se comentan los problemas encontrados a lo largo de mas de 40 auditorias realizadas a inmuebles grandes de diversos tipos en la ciudad de Mexico.

  4. Fluid-dynamic behavior of flaxseed fluidized and spouted bed

    Directory of Open Access Journals (Sweden)

    Elza Brandão Santana

    2017-09-01

    Full Text Available ABSTRACT: Processing of particles in a moving bed, such as a fluidized bed or a spouting bed, is commonly used in the operations of drying, coating, and granulation of particulate systems. This process has applications in the chemical, pharmaceutical and, presently, agronomical industries, especially for seed treatment/coating. This research aimed to analyze the fluid-dynamic behavior of fluidized and spouting beds with different air temperatures and loads of flaxseeds (Linum usitatissimum L., with estimates of the fluid-dynamic parameters correlated to each process. The parameters were compared with the values obtained from classical correlations in the literature, with indications of associated percentages of deviation. Influence of fluid dynamics on the physiological quality of seeds was assessed by germination tests and the germination speed index. An analysis of the results indicated that seed processing was adequate for processing in dynamically active beds; however, temperatures above 50ºC in both beds caused significant reductions in the physiological quality of the seeds. Processing in a fluidized bed presented a smaller reduction of the physiological properties of the flaxseed.

  5. Modelling of dynamics of combustion of biomass in fluidized beds

    Directory of Open Access Journals (Sweden)

    Saastamoinen Jaakko J.

    2004-01-01

    Full Text Available New process concepts in energy production and biofuel, which are much more reactive than coal, call for better controllability of the combustion in circulating fluidized bed boilers. Simplified analysis describing the dynamics of combustion in fluidized bed and circulating fluidized bed boilers is presented. Simple formulas for the estimation of the responses of the burning rate and fuel inventory to changes in fuel feeding are presented. Different changes in the fuel feed, such as an impulse, step change, linear increase and cyclic variation are considered. The dynamics of the burning with a change in the feed rate depends on the fuel reactivity and particle size. The response of a fuel mixture with a wide particle size distribution can be found by summing up the effect of different fuel components and size fractions. Methods to extract reaction parameters form dynamic tests in laboratory scale reactors are discussed. The residence time of fuel particles in the bed and the resulting char inventory in the bed decrease with increasing fuel reactivity and differences between coal and biomass is studied. The char inventory affects the stability of combustion. The effect of char inventory and oscillations in the fuel feed on the oscillation of the flue gas oxygen concentration is studied by model calculation. A trend found by earlier measurements is explained by the model.

  6. Collaborative research on fluidization employing computer-aided particle tracking

    International Nuclear Information System (INIS)

    Chen, M.M.

    1990-01-01

    The objective of this work is to obtain unique, fundamental information on fluidization dynamics over a wide range of flow regimes using a Transportable Computer-Aided Particle Tracking Apparatus (TCAPTA). The contractor will design and fabricate a transportable version of the Computer-Aided Particle Tracking Facility (CAPTF) he has previously developed. The contractor will install and operate the (TCAPTA) at the METC fluidization research facilities. Quantitative data on particle motion will be obtained and reduced. The data will be used to provide needed information for modeling of bed dynamics, and prediction of bed performance, including erosion. A radioactive tracer particle, identical in size shape and mass to the bed particles under study, is mixed in the bed. The radiation emitted by the tracer particle, monitored continuously by 16 scintillation detectors, allows its position to be determined as a function of time. Stochastic mixing processes intrinsic to fluidization further cause the particle to travel to all active regions of the bed, thus sampling the motion in these regions. After a long test run to insure that a sufficient sampling have been acquired, time-differentiation and other statistical processing will then yield the mean velocity distribution, the fluctuating velocity distribution, many types of auto- and cross correlations, as well as mean fluxes, including the mean momentum fluxes due to random motion, which represent the kinetic contributions to the mean stress tensor

  7. The heat transfer mechanisms in fluidized beds; Laemmoensiirtomekanismit leijukerroksessa

    Energy Technology Data Exchange (ETDEWEB)

    Fogelholm, C.J.; Blomster, A.M.; Kojola, H. [Helsinki Univ. of Technology, Espoo (Finland)

    1996-12-01

    The goal of the research project is to improve the accuracy of the heat transfer correlation in circulating fluidized beds and to define how the heat transfer is distributed in radiation and convection in the different parts of the fluidized bed. This will be carried out by studying the behaviour and heat transfer of the fluidized bed in the boundary layer near the wall. The total and radiative heat transfer as well as the particle concentration will be measured. Based on the data a correlation will be created. Two different measurement systems are used. The particle concentration is measured by a image-analysis system. A video camera and a Super VHS recorder are used to capture live images from the bed. The images are digitized and stored on a PC. The system has been used in previous research projects at our laboratory. In earlier projects all measurements have been carried out in cold environments. In this project the system will be modified for hot environments. The radiative heat transfer is measured by a radiative heat transfer probe connected to a PC via an A/D converter. The probe consists of a heat flow detector which is isolated from the bed by a sapphire window so that only the radiative part of the heat transfer is detected. The probe will be calibrated in a black body oven so that the effect of the conduction and the sapphire window can be separated. (author)

  8. Tar removal during the fluidized bed gasification of plastic waste.

    Science.gov (United States)

    Arena, Umberto; Zaccariello, Lucio; Mastellone, Maria Laura

    2009-02-01

    A recycled polyethylene was fed in a pilot plant bubbling fluidized bed gasifier, having an internal diameter of 0.381 m and a maximum feeding capacity of 90 kg/h. The experimental runs were carried out under various operating conditions: the bed temperature was kept at about 850 degrees C, the equivalence ratio varied between 0.2 and 0.35, the amount of bed material was between 131 and 215 kg, the fluidizing velocity was between 0.5 and 0.7 m/s, quartz sand and olivine were used as bed material, and air and steam were used as fluidizing reactants. The results confirm that the tar removal treatments applied inside the gasifier (primary methods) can eliminate or strongly reduce the need for a further downstream cleanup of the syngas. In particular, the utilization of a natural olivine as an in situ tar reduction agent remarkably improves the quality of the product gas, in terms of both high hydrogen volumetric fraction and larger syngas yield.

  9. Production of electric power with domestic wastes. Thermal valorization of wastes in circulating fluidized bed; Produccion de energia electrica a partir de basura domestica. Valorizacion termica de basura en lecho fluido circulante

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    Lurgi`s WIKONEX process (waste conversion process) achieves with high efficiency the recovery of the waste-borne energy due to: - the utilization of a fluid bed superheater to overheat the steam in the gasification system (operation with higher steam parameters). - the utilization of air for gasification and combustion at high temperature (minimization of self-consumption). - waste drying (minimization of the gas volume) After the grinding and drying, the waste will be gasified with the addition of air in the circulating fluid bed (CFB). The generated gas will be burnt in a combustion chamber at high temperatures, destroying the existing organic substances, including dioxins and furans. At the same time, the ashes carried with by the gas (as well as the bottom ashes from the gasifier and the fly ashes from the flue gas cleaning process) will be fused to obtain a vitrified granular, as good as non lixiviable which can be used as construction material. The superheated high pressure steam generated in the recovery boiler/fluid bed superheater will be sent to a turbine for the generation of electric energy. In the flue gas cleaning process will be produced gypsum and chlorhydric acid as subproducts, whilst at the end of the effluent treatment there will remain small amounts of heavy metal dusts and salts which have to be eliminated as special waste. The emissions through the stack are clearly lower than the limit value given by the seventeenth Federal Decree on Emission Control (17. Bundes-Immissions-Schutz-Verordnung). Lurgi`s WIKONEX process is very flexible regarding the types of waste to be used (residual household waste, assimilable waste, sewage sludges, other types of wastes).

  10. Electrical energy saving in motors and frequency variators; Ahorro de energia electrica en motores y variadores de frecuencia

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Neri, Roger [Comision Federal de Electricidad (CFE) (Mexico)

    2005-07-01

    The necessity of saving energy is urgent and undeniable. We must already begin with the rational use of energy. Which is obtaining the maximum benefit of the consumed energy and of the necessary facilities for its generation, transmission and use. Guaranteeing at the same time an operation free of interferences or interruptions for the users. The electricity in alternating current does not allow its storage, reason why it is necessary to generate and distribute it at the precise moment when it is required. This forces to determine the proportions of the generation facilities, to be able to feed the periods of maximum demand called {sup p}eaks{sup .} It is this very point where the problem of the inappropriate use of the electrical energy starts. The energy waste is self-evident during the periods of low demand because of the low efficiency of the sub-utilized facilities. Electrical motors of the induction type use approximately more than 60% of the energy in the industry. If we use high efficiency motors instead of standard motors, a better advantage of the energy demanded from Comision Federal de Electricidad (CFE) is obtained. [Spanish] Es impostergable e innegable la necesidad de ahorrar energia. Tenemos que empezar ya con el uso racional de la energia: Obtener el maximo beneficio de la energia consumida y de las instalaciones necesarias para su generacion, transmision y utilizacion. Garantizando a los usuarios un funcionamiento sin interferencias o interrupciones. La electricidad en corriente alterna no permite su almacenamiento, por lo que es necesario generarla y distribuirla en el momento preciso en que es requerida. Esto obliga a dimensionar las instalaciones de generacion, para poder alimentar los periodos de maxima demanda llamados pico. Desde esta parte inicia el problema de la mala utilizacion de la energia electrica. Ya que en los periodos de baja demanda, las instalaciones se encuentran subutilizadas y si su eficiencia es muy baja, el desperdicio de

  11. Las investigaciones de la Escuela de Ciencias de la Educación de la Universidad Nacional de Rosario

    OpenAIRE

    Bertramo, Brenda Caren; Mosso, Agustina Guadalupe; Pozzo, María Isabel Rita

    2017-01-01

    A partir de las investigaciones presentadas en el Foro 2012 de Investigaciones de la Escuela de Ciencias de la Educación de la UNR, se analizan las características de su producción académica en lo que refiere a: composición de los equipos, instituciones acreditadoras y duración total de modo de aportar a la sistematización y diagnóstico de esta importante faceta del quehacer de la Escuela. Fil: Bertramo, Brenda Caren. Universidad Nacional de Rosario. Facultad de Humanidades y Artes. Escuel...

  12. Selective catalytic reduction of nitrogen oxide with ammonia in a novel reactor called the floating gas-solid fluidized bed

    NARCIS (Netherlands)

    Kwant, G.J.; Kwant, G.J.; Prins, W.; van Swaaij, Willibrordus Petrus Maria

    1995-01-01

    The floating gas-solid fluidized bed (FGSFB) is a new type of gas-solid contacting device described earlier by Kwant et al. (Fluidization VII, Proc. 7th Engng Foud. Conf. on Fluidization, Brisbane, May, 1992). It is a tapered column provided with several coarse grids, in which catalyst particles are

  13. Discrete particle simulations of an electric-field enhanced fluidized bed

    NARCIS (Netherlands)

    Kleijn van Willigen, F.; Demirbas, B.; Deen, N.G.; Kuipers, J.A.M.; Ommen, J.R.

    2008-01-01

    Reducing the size of gas bubbles can significantly improve the performance of gas–solid fluidized reactors. However, such a control of bubbles is difficult to realize without measures that either use a lot of energy or deteriorate the fluidization behavior. In this paper, we present the results of

  14. Investigation of the particle flowpattern and segregation in tapered fluidized bed granulators

    NARCIS (Netherlands)

    Schaafsma, S. H.; Marx, T.; Hoffmann, A. C.

    The particle flowpattern and granule segregation in tapered fluidized beds have been studied using two techniques. The first technique is to fluidize beds of varying total mass and granule fractions, then defluidize them suddenly to "freeze" the composition, section the bed in layers, and determine

  15. Discrete element study of granulation in a spout-fluidized bed

    NARCIS (Netherlands)

    Link, J.M.; Godlieb, W.; Deen, N.G.; Kuipers, J.A.M.

    2007-01-01

    In this work a discrete element model (DEM) is presented for the description of the gas–liquid–solid flow in a spout-fluidized bed including all relevant phenomena for the study of granulation. The model is demonstrated for the case of a granulation process in a flat spout-fluidized bed, containing

  16. Discrete element modeling and fibre optical measurements for fluidized bed spray granulation

    NARCIS (Netherlands)

    Link, J.M.; Godlieb, W.; Deen, N.G.; Heinrich, S.; Tripp, P.; Peglow, M.; Kuipers, J.A.M.; Schönherr, M.; Mörl, L.

    2007-01-01

    Spout fluidized beds are frequently used for the production of granules or particles through granulation. The products find application in a large variety of applications, for example detergents, fertilizers, pharmaceuticals and food. Spout fluidized beds have a number of advantageous properties,

  17. Characterization of granular phase change materials for thermal energy storage applications in fluidized beds

    International Nuclear Information System (INIS)

    Izquierdo-Barrientos, M.A.; Sobrino, C.; Almendros-Ibáñez, J.A.; Barreneche, C.; Ellis, N.; Cabeza, L.F.

    2016-01-01

    Highlights: • Granular PCMs are tested in 3D and 2D fluidized beds. • Density, particle size and angle of repose were measured for different granular PCMs. • DSC measurements confirm that there is no loss of material after fluidization. - Abstract: This work investigates commercially available granular phase change materials (PCMs) with different transition temperatures for the use of thermal-energy storage systems in fluidized beds. The hydrodynamic characteristics of granular PCMs were tested in cylindrical-3D and planar-2D fluidized beds. The density, particle size distribution and angle of repose were measured for various PCM materials. Further attrition studies were conducted with changes in particle surface from abrasion, which were characterized using a Scanning Electron Microscope (SEM). The results indicate that some materials with smaller particle size and thinner supporting structure can lose the paraffin during the fluidization process, when paraffin is in a liquid state. As a consequence, the particles agglomerate, and the bed defluidizes. For all of the tested materials, only GR50 (with a transition temperature of 50 °C) properly fluidizes when the paraffin is in the liquid state and has shown to endure >75 h of continuous operation and 15 melting-solidification cycles in a fluidized bed. Additional differential scanning calorimetry (DSC) measurements of the cycled particles did not show a decrease in energy storage capacity of the granular PCM, which corroborates that there is no loss of material after >75 h of fluidization.

  18. Mathematical modeling of a fluidized bed rice husk gasifier: Part 2 - Model sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Mansaray, K.G.; Ghaly, A.E.; Al-Taweel, A.M.; Hamdullahpur, F.; Ugursal, V.I.

    2000-02-01

    The performance of two thermodynamic models (one-compartment and two-compartment models), developed for fluidized bed gasification of rice husk, was analyzed and compared in terms of their predictive capabilities of the product gas composition. The two-compartment model was the most adequate to simulate the fluidized bed gasification of rice husk, since the complex hydrodynamics present in the fluidized bed gasifier were taken into account. Therefore, the two-compartment model was tested under a wide range of parameters, including bed height, fluidization velocity, equivalence ratio, oxygen concentration in the fluidizing gas, and rice husk moisture content. The model sensitivity analysis showed that changes in bed height had a significant effect on the reactor temperatures, but only a small effect on the gas composition, higher heating value, and overall carbon conversion. The fluidization velocity, equivalence ratio, oxygen concentration in the fluidizing gas, and moisture content in rice husk had dramatic effects on the gasifier performance. However, the model was more sensitive to variations in the equivalence ratio and oxygen concentration in the fluidizing gas. (Author)

  19. Mathematical modeling of a fluidized bed rice husk gasifier: Part 2 -- Model sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Mansaray, K.G.; Ghaly, A.E.; Al-Taweel, A.M.; Hamdullahpur, F.; Ugursal, V.I.

    2000-03-01

    The performance of two thermodynamic models (one-compartment and two-compartment models), developed for fluidized bed gasification of rice husk, was analyzed and compared in terms of their predictive capabilities of the product gas composition. The two-compartment model was the most adequate to simulate the fluidized bed gasification of rice husk, since the complex hydrodynamics present in the fluidized bed gasifier were taken into account. Therefore, the two-compartment model was tested under a wide range of parameters, including bed height, fluidization velocity, equivalence ratio, oxygen concentration in the fluidizing gas, and rice husk moisture content. The model sensitivity analysis showed that changes in bed height had a significant effect on the reactor temperatures, but only a small effect on the gas composition, higher heating value, and overall carbon conversion. The fluidization velocity, equivalence ratio, oxygen concentration in the fluidizing gas, and moisture content in rice husk had dramatic effects on the gasifier performance. However, the model was more sensitive to variations in the equivalence ratio and oxygen concentration in the fluidizing gas.

  20. Biomass Gasification in Internal Circulating Fluidized Beds: a Thermodynamic Predictive Tool

    Czech Academy of Sciences Publication Activity Database

    Miccio, F.; Svoboda, Karel; Schosger, J.-P.; Baxter, D.

    2008-01-01

    Roč. 25, č. 4 (2008), s. 721-726 ISSN 0256-1115 Institutional research plan: CEZ:AV0Z40720504 Keywords : fluidized bed * gasification * fluidized bed Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 0.830, year: 2008

  1. Volatiles combustion in fluidized beds. Final technical report, 4 September 1992--4 June 1995

    Energy Technology Data Exchange (ETDEWEB)

    Pendergrass, R.A. II; Raffensperger, C.; Hesketh, R.P.

    1996-02-29

    The goal of this project is to investigate the conditions in which volatiles will burn within both the dense and freeboard regions of fluidized beds. Experiments using a fluidized bed operated at incipient fluidization are being conducted to characterize the effect of particle surface area, initial fuel concentration, and particle type on the inhibition of volatiles within a fluidized bed. A review of the work conducted under this grant is presented in this Final Technical Report. Both experimental and theoretical work have been conducted to examine the inhibition of the combustion by the fluidized bed material, sand. It has been shown that particulate phase at incipient fluidization inhibits the combustion of propane by free radical destruction at the surface of sand particles within the particulate phase. The implications of these findings is that at bed temperatures lower than the critical temperatures, gas combustion can only occur in the bubble phase or at the top surface of a bubbling fluidized bed. In modeling fluidized bed combustion this inhibition by the particulate phase should be included.

  2. The influence of transport phenomena on the fluidized bed combustion of a single carbon particle

    NARCIS (Netherlands)

    Prins, W.; van Swaaij, Willibrordus Petrus Maria

    1990-01-01

    The burning rate and temperature of the carbon particles are known to affect the efficiency of a fluidized bed combustor, and also the emission levels of undesired noxious components. The main results of an extensive study on the fluidized bed combustion behaviour of a single carbon particle [1] are

  3. The combustion of low calorific value fuels (oil shale) by using fluidized bed combustor

    International Nuclear Information System (INIS)

    Azzam, S.M.

    1993-01-01

    The present work reports an experimental data for combustion of oil-shale in a fluidized bed combustor. The experimental set up was designed for the combustion of low calorific value fuel such as oil-shale to facilitate the variation of many parameters over a wide operating range. A cold run was firstly conducted to study the fluidization parameters. Fluidization experiment were made with different sized quartiz particles. Minimum fluidization velocities and other fluidization characteristics were determined at room temperature. Secondary a hot run was started, first studying the combustion of 'LPG' in a fluidized bed as a starting process, then studying the combustion if oil-shale with different flow rates. The experimetal results are promising and give rise to hopes that this valuable deposit can be used as a fuel source and can be burned sucessfully in a fluidized bed combustor. This study had prooved that utilization of oil-shale a fuel source is no more a complicated technical problem, this opens the way for power generation using fluidized bed combustors. (author). 17 refs., 32 figs., 3 tabs

  4. Combining fluidized activated carbon with weak alternating electric fields for disinfection

    NARCIS (Netherlands)

    Racyte, J.; Sharabati, J.; Paulitsch-Fuchs, A.H.; Yntema, D.R.; Mayer, M.J.J.; Bruning, H.; Rijnaarts, H.H.M.

    2011-01-01

    This study presents fluidized bed electrodes as a new device for disinfection. In the fluidized bed electrodes system, granular activated carbon particles were suspended, and an alternating radio frequency electric field was applied over the suspended bed. Proof-of-principle studies with the

  5. Investigaciones paleontológicas en el Valle de Puebla durante el siglo xx

    Directory of Open Access Journals (Sweden)

    Jorge A. Herrera Flores

    2017-01-01

    Full Text Available Se ofrece una extensa revisión bibliográfica y hemerográfica de los trabajos paleontológicos realizados en el Valle de Puebla desde principios del siglo xx hasta la actualidad. Se hace especial énfasis en los estudios efectuados por el Proyecto Valsequillo y la Fundación Alemana para la Investigación Científica, dado que estos aportaron las mayores contribuciones al conocimiento de la paleontología del Valle de Puebla. Además, se proporcionan datos inéditos sobre las exploraciones que dieron origen a la colección paleontológica del extinto Museo de Historia Natural de Puebla y se comenta sobre el inicio de las investigaciones actuales y su perspectiva hacia el futuro.

  6. INVESTIGACIONES EUROPEAS DE DIRECCIÓN Y ECONOMÍA DE LA EMPRESA. INFORME EDITORIAL

    Directory of Open Access Journals (Sweden)

    Guisado Tato, M.

    2010-01-01

    Full Text Available En este informe se revisa el proceso editorial de Investigaciones Europeas de Dirección y Economía de la Empresa durante 2009 y se avanzan algunos datos del año 2010. En 2009 se recibieron 92 manuscritos procedentes fundamentalmente de España (95,7%. Consecuentemente, el idioma más utilizado fue el español, seguido del portugués y el inglés. En este año, el tiempo medio entre recepción y publicación ha sido relativamente bajo (296 días para lo que resulta habitual en la mayoría de publicaciones del área de economía de la empresa. La tasa de rechazo fue del 70,71%, publicándose un total de 34 artículos de investigación originales.

  7. Una experiencia de capacitacion-investigacion a docentes coordinadores de pronoei del callao

    Directory of Open Access Journals (Sweden)

    Carmen Coloma

    1992-06-01

    Full Text Available En 1983la Facultad de Educación de la Pontificia Universidad Católica del Perú conjuntamente con la Fundación de Investigaciones Educativas High Scope, inició un Proyecto de Capacitación a personal no profesional en servicio. Esta experiencia piloto que se realizó en 5 programas no escolarizados de Educación Inicial de sectores urbano marginales de Lima y Callao, permitió validar un modelo de capacitación que tiene principios y estrategias muy particulares y cuyos resultados están relacionados con el mejoramiento de la calidad de servicios educativos, el desempeño de animadoras y la participación de la comunidad, lo cual ha propiciado su extensión a otros sectores y niveles.

  8. ELEMENTOS METODOLOGICOS INICIALES EN UN PROCESO DE INVESTIGACION - EXTENSION. EL CASO DE CAÑO NEGRO

    Directory of Open Access Journals (Sweden)

    Ligia Martín José Francisco Miranda

    2012-11-01

    Full Text Available Aprovechando la realización de este seminario, hemos querido presentar ante los extensionistas de nuestra Facultad, unas primeras notas acerca del "Proyecto Piloto para la Gestión Productiva-Ambiental con los Pobladores de Caño Negro, Refugio de Vida Silvestre". El propósito de este trabajo inicial, es poner en discusión algunos de los elementos metodológicos que hemos ubicado, al momento de arrancar con un proyecto de investigación-extensión, que pretende recurrir a los procedimientos desarrollados y utilizados en los procesos de INVESTIGACION PARTICIPATIVA, INVESTIGACION ACCION. Además y haciendo eco de las intensiones de este seminario, se espera sirva de elemento para la reflexión conjunta de aspectos de esta naturaleza, que a la postre resultan ser problemas comunes o al menos semejantes, y que además, están en el tapete de la discusión y el análisis. Como la mayoría de ustedes saben, se trata del proyecto de extensión que las escuelas de Sociología, Ambientales, Planificación y Promoción Social y Geografía, iniciaron en marzo de este año en Caño Negro, distrito del cantón de Los Chiles, Alajuela, el cual describiremos con más detalle a continuación.

  9. Redes de contacto sociales: ?(spanishfactor clave para la labor de investigacion universitaria?

    Directory of Open Access Journals (Sweden)

    Hermosilla Yenia Melo

    2002-01-01

    Full Text Available Dentro del ámbito de la labor universitaria, el nexo permanente entre docencia, investigación y difusión, constituye un factor de vital importancia. Bajo este prisma, un elemento fundamental para la formación permanente del personal académico es su compromiso con la realización de investigaciones, que contribuyan a generar nuevos conocimientos y a ampliar sus perspectivas de desarrollo. Siguiendo esta línea de razonamiento, este artículo examina el medio ambiente de investigación universitaria, específicamente, el tema de la vinculación o red de contactos de 19 investigadores, pertenecientes a diferentes áreas del conocimiento, con la sociedad circundante y el mundo de la investigación. Las bases teóricas del estudio se relacionan con dos niveles de análisis. El primero de naturaleza sociológica, se centra en la relación ciencia-sociedad. El segundo, de naturaleza psicológica, aborda aspectos que se refieren a la relación individuo-conocimiento. La perspectiva cualitativa, a través de una aproximación fenomenográfica, describe la metodología empleada en este estudio. Por ello, las percepciones del grupo de académicos participantes, fueron conocidas a través de entrevistas en profundidad. Los resultados revelan características de las redes de contacto, motivaciones que originan estos vínculos, estrategias relacionadas con su forma de construcción y de utilización, efectos en la labor de investigación. El estudio concluye con reflexiones finales, entre las que se destacan posibles proyectos para futuras investigaciones sobre el tema abordado.

  10. Conversion of ammonium uranyl carbonate to UO2 in a fluidized bed

    International Nuclear Information System (INIS)

    Zhao Jun; Qiu Lufu; Zhong Xing; Xu Heqing

    1989-11-01

    The conversion of AUC (Ammonium Uranyl Carbonate) to UO 2 was studied in a fluidized bed of 60 mm inner diameter based on the thermodynamics and kinetics data of decomposition-reduction of AUC. The influence of the reaction temperature, composition of fluidization gas and fluidization velocity on conversion were investigated by using N 2 , Ar and circulation gas (mixing gas of H 2 and CO obtained from the exhaust gas of the decomposition of AUC by catalyst crack-conversion) as the fluidization gas. The throughput is up to the high levels (3.32 kg(wet)/h·L) by using circulation gas or mixing of circulation gas and Ar (< 21%) as the fluidization gas when the reaction temperature exceeds 570 deg C

  11. Factors affecting the amounts of emissions arising from fluidized bed combustion of solid fuels

    International Nuclear Information System (INIS)

    Horbaj, P.

    1996-01-01

    The factors affecting the amounts of nitrogen oxides (NO x ) and sulfur oxides (SO x , i.e. SO 2 + SO 3 ) formed during fluidized bed combustion of fossil fuels are analyzed using both theoretical concepts and experimental data. The factors treated include temperature, excess air, fuel parameters, pressure, degree of combustion gas recycling, combustion distribution along the combustion chamber height, and sulfur trapping processes for NO x , and the Ca/S ratio, fluidized layer height and fluidization rate, granulometry and absorbent type, fluidized layer temperature, and pressure during combustion for SO x . It is concluded that fluidized bed boilers are promising power generating facilities, mitigating the environmental burden arising from fossil fuel combustion. (P.A.). 12 figs., 9 refs

  12. PENGARUH MASSA JENIS PARTIKEL DAN KETINGGIAN PARTIKEL TERHADAP FENOMENA FLUIDISASI DALAM FLUIDIZED BED DENGAN MENGGUNAKAN CFD

    Directory of Open Access Journals (Sweden)

    Rosyida Permatasari

    2016-12-01

    Full Text Available Fenomena fluidisasi pada fluidized bed yaitu kecepatan minimum dan tekanan statis partikel merupakan hal fenomena yang penting dalam desain fluidized bed. Fenomena-fenomena tersebut dipengaruhi oleh banyak faktor dalam fluidized bed diantaranya massa jenis dan tinggi partikel di dalam fluidized bed. Penelitian ini menggunakan jenis partikel yang berbeda-beda dan rasio ketinggian partikel terhadap diameter fluidized bed (H/D dengan menggunakan Computational Fluid Dynamics. Partikel yang digunakan adalah partikel dengan jenis Geldart B yaitu glass beads (ρ=2600 kg/m3, ground walnut shell (ρ=1200 kg/m3 dan ground corncob (ρ=800 kg/m3, sedangkan rasio ketinggian partikel yang digunakan yaitu 0.5, 1, 1.5, 2, dan 2.5. Hasil penelitian menunjukkan bahwa massa jenis partikel berbanding lurus dengan kecepatan minimum fluidisasi dan ketinggian partikel tidak mempengaruhi kecepatan minimum fluidisasi.

  13. Magnetic losses and reactance change by the use of metallic conduit in electrical installations; Perdidas magneticas y cambio de reactancia por la tuberia metalica en instalaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Campero Littlewood, Eduardo; Castaneda D, Miguel; Castulo A, Roberto; Bratu Serban, Neagu [Universidad Autonoma Metropolitana-Azcapotzalco, Mexico, D. F. (Mexico)

    1996-12-31

    In this paper are presented the results obtained in the measurement of magnetic losses in metallic conduits in electric installations. The losses for parasitic currents and by hysteresis were obtained in different conditions of magnetic density, caused by the net current resulting from the sum of all the currents of all the conductors that travel along the conduit. These currents are named differential currents, and the conditions in which they appear in the electric installations are described. The magnetic induction phenomenon that occurs in metallic conduit is briefly described and the basic concepts that describe it. A theoretical-experimental methodology is offered to quantify the energy losses by parasitic currents and by the metal magnetization in these metallic conduits. At the same time, the impact of these differential currents impact in the reactance of the electric installation is quantified. The obtained results for twelve conduits of different diameters and different wall thickness are shown. A comparison analysis is made with the reported results in a previous article, where the losses were estimated by means of the temperature rise measurement of the metallic wall. [Espanol] En este articulo se presentan los resultados obtenidos en la medicion de perdidas magneticas en tuberias conduit (metalicas) en instalaciones electricas. Las perdidas por corrientes parasitas y por histeresis se obtuvieron para diferentes condiciones de densidad magnetica, provocada por la corriente neta resultante de la suma de las corrientes de todos los conductores que viajan por la tuberia. A estas corrientes se les designa corrientes diferenciales y se describen las condiciones en las que estas aparecen en las instalaciones electricas. Se explica brevemente el fenomeno de induccion magnetica que se presenta en las tuberias metalicas y los conceptos basicos que la describen. Se plantea una metodologia teorico-experiemental para cuantificar las perdidas de energia, por

  14. Planning the expansion of electrical transmission networks with evolutionary programming; Planeacion de la expansion de redes de transmision electrica con programacion evolucionaria

    Energy Technology Data Exchange (ETDEWEB)

    Ceciliano Meza, Jose Luis

    1997-12-31

    In this work it is presented for the first time in the literature the solution of the problem of the planning the expansion of an electrical transmission network (PERTE) with the use of the Evolutionary Programming. The evolutionary programming is a stochastic method of optimization with similar characteristics to the generic algorithms, but different. During the development of this work it is shown what each one of these two heuristic methods of optimization consist of. Additionally, the main characteristics of other two heuristic methods known in the literature are described (Tabu Searching and Simulated Annealing). These two methods together with the genetic algorithms and decomposition of Benders have also been used to solve the problem of planning PERTE. The operation of the proposed algorithm of evolutionary programming was tested in two networks of electrical transmission. The first case of test is a system which is known in the literature. The second case is a representative system of the electrical transmission network of Central America. The results obtained improve all the results shown when applying different heuristic methods of optimization (genetic algorithms, simulated annealing and Tabu searching) to solve the same problem. [Espanol] En este trabajo se presenta por primera vez en la literatura, la solucion del problema de la planeacion de expansion de una red de transmision electrica (PERTE) con el uso de la Programacion Evolucionaria. La programacion evolucionaria es un metodo estocastico de optimizacion con caracteristicas similares a los algoritmos geneticos, pero diferente. Durante el desarrollo de este trabajo se muestra en que consiste cada uno de estos dos metodos heuristicos de optimizacion. Ademas, se describen las caracteristicas principales de otros dos metodos heuristicos conocidos en la literatura (busqueda Tabu y Recorrido Simulado). Estos dos metodos juntos con los algoritmos geneticos y descomposicion de Benders tambien han sido

  15. Thermofluid effect on energy storage in fluidized bed reactor

    Science.gov (United States)

    Mahfoudi, Nadjiba; El Ganaoui, Mohammed; Moummi, Abdelhafid

    2016-05-01

    The development of innovative systems of heat storage is imperative to improve the efficiency of the existing systems used in the thermal solar energy applications. Several techniques were developed and realized in this context. The technology of the sand fluidized bed (sandTES) offers a promising alternative to the current state-of-the-art of the heat storage systems, such as fixed bed using a storage materials, as sand, ceramic, and stones, etc. Indeed, the use of the fluidization technique allows an effective heat transfer to the solid particles. With the sand, an important capacity of storage is obtained by an economic and ecological material [N. Mahfoudi, A. Moummi, M. El Ganaoui, Appl. Mech. Mater. 621, 214 (2014); N. Mahfoudi, A. Khachkouch, A. Moummi B. Benhaoua, M. El Ganaoui, Mech. Ind. 16, 411 (2015); N. Mahfoudi, A. Moummi, M. El Ganaoui, F. Mnasri, K.M. Aboudou, 3e Colloque internationale Francophone d"énergétique et mécanique, Comores, 2014, p. 91]. This paper presents a CFD simulation of the hydrodynamics and the thermal transient behavior of a fluidized bed reactor of sand, to determine the characteristics of storage. The simulation shows a symmetry breaking that occurs and gave way to chaotic transient generation of bubble formation after 3 s. Furthermore, the predicted average temperature of the solid phase (sand) increases gradually versus the time with a gain of 1 °C in an interval of 10 s. Contribution to the topical issue "Materials for Energy Harvesting, Conversion and Storage (ICOME 2015) - Elected submissions", edited by Jean-Michel Nunzi, Rachid Bennacer and Mohammed El Ganaoui

  16. Fluidized bed granulation of an ordered powder mixture.

    Science.gov (United States)

    Thiel, W J; Nguyen, L T

    1982-11-01

    The phenomenon of ordered unit segregation is of paramount importance in determining the homogeneity of an ordered mixture. This problem can be avoided by using a monodisperse carrier, but it is uneconomic. The fluidized bed granulation of a 0.1% ordered mixture has been studied as a method of reducing the effects of segregation. The ordered units were stable when fluidized and no significant loss of the microfine adsorbed material occurred during processing. The distribution of the minor component in the granules was significantly more uniform than in the original ordered mixtures. The demixing potential (formula: see text) (where p = proportion of cohesive minor component and w is the weight % of carrier material in a particular size range) was used to quantify the distribution of the minor component as a function of particle size. DP is a coefficient of variation and can be directly compared with the specification standard deviation sigma A. Batches of granules were compressed into 100 or 350 mg tablets, containing approximately 100 and 350 micrograms of model drug substance. The weight and content coefficients of variation (c.v.) were determined for 20 tablets. All batches had a weight c.v. less than or equal to 1.5% and a content c.v. less than or equal to 4.6%. Granulation of an ordered mixture greatly reduces the potential for segregation to decrease the mixture homogeneity. It also provides a solution to the problems which may be encountered when the mixing of small quantities of cohesive materials during conventional fluidized bed granulation is attempted.

  17. Retrieval of fluidizable radioactive wastes from storage facilities

    International Nuclear Information System (INIS)

    2006-08-01

    This report provides guidance for strategic planning and implementation of resuspension and retrieval of stored fluid or fluidizable radioactive wastes. The potential risks associated with preparation and realization of these processes are included in the report, and lessons learned from previous applications are highlighted. Technological procedures and equipment used in various countries for resuspension and remobilization of stored fluidizable radioactive wastes are described in the attached annexes as potential options. Waste retrieval is a maturing technology of major importance now that Member States are moving forward in the responsible management of wastes by removal to safe interim storage or disposal. Retrieval of fluidizable wastes is a four-phase operation: (1) access to the waste, (2) mobilize the waste, (3) remove the waste; and (4) transfer the waste.This report divides successful retrieval of radioactive waste into two areas. The first area applies the concept of the waste retrieval as being the final component of a systematic process of old waste management. It also encompasses characterization as it applies to waste retrieval and downstream processes, including acceptance of wastes for treatment, conditioning, storage or disposal. It should be in conformity with national policy, as well as complying with international safety standards and environmental agreements. The second area of the report focuses on implementation of waste retrieval in a wide range of scenarios and using a wide range of retrieval approaches, equipment and technologies. Technical processes are further explained as part of the experience gained in advanced countries on the subject. A set of detailed retrieval technology descriptions by country is included as Annexes to this report. Thirteen experts from seven Member States that previously implemented, or have planned for the near future, significant resuspension and remobilization operations were involved in the preparation of

  18. Materials support for EPRI Fluidized-Bed Combustion Program

    International Nuclear Information System (INIS)

    Sethi, V.K.; Wright, I.G.

    1993-05-01

    This research project was intended to provide technical support for materials aspects of EPRI's U.C. Fluidized Bed Combustor Program. The scope of this support included participation in the EPRI FBC materials oversight panel, inspection of fluidized beds during forced or planned outages, analysis of materials failures and of associated deposits, participation in technical meetings involving fluidized bed materials. Volume I describes the results of exposing for approximately 5,000 hours in the Georgetown AFBC a number of surface modifications that had been reported to have promise in combating in-bed evaporator tube wastage. Some measures were applied to sample lengths of carbon-steel tubing, and installed as part of the in-bed evaporator tube bundle at Georgetown. These tubes are inspected periodically while still installed in the unit, and were finally cut out and subjected to detailed measurements and metallographic evaluation. The exposure at regular intervals throughout the bed of plain carbon-steel tubes that were honed and surface-ground allowed a baseline measurement of the wastage potential of this bed, which was high. Qualitatively, all but one of the protective measures tested reduced wastage. The unprotected tubes showed that wastage occurred mainly on the underside of the tubes, with maximum wear at the tube bottom. The protective measures that were exposed were densely studded tubes, fins and flow separators, fins and studs on the underside of the tube, and longitudinal rods. These surface modifications were exposed in the chromized and unchromized conditions, together with plain carbon-steel tubes that had been chromized. The tubes with fins and flow separators exhibited continued wastage on the underside between the flow separators, which was attributed in part to the steep inclination of the tubes in the bed. The plain, chromized tubes, together with the armored, chromized tubes, exhibited virtually no wastage of the tube surface nor of the armor

  19. Evolution of the Radio-sterilized Tissues Bank of the Instituto Nacional de Investigaciones Nucleares; Evolucion del Banco de Tejidos Radioesterilizados del Instituto Nacional de Investigaciones Nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Martinez P, M. E.; Reyes F, M. L.; Luna Z, D., E-mail: esther.martinez@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2013-10-15

    The Radio-sterilized Tissues Bank (RTB) of the Instituto Nacional de Investigaciones Nucleares (ININ) was established in 1997, as national project supported by the IAEA, who provided equipment, training and expert missions. In July of 1999, the Secretaria de Salud (Mexico) granted the sanitary license to the RTB. The first radio-sterilized tissue was the amnion. Later on, the process of frozen and lyophilized pig skin was development. Both tissue types are used as biological dressings in patient with burns, ulcers or on injuries difficult to heal, the amnion is also used for the damage treatment in the ocular surface. In 2003, the ININ improved the facilities of the RTB and in August of that same year the certification of the Quality Administration System was obtained under the standard ISO 9001:2000, at the present time ISO 9001:2008. The support of the IAEA granted to Mexico was of 1997-2004 and 2009-2012, by means of regional and inter regional projects where was obtained equipment and training mainly, for personal of the ININ and other institutions. With the last project supported by the IAEA, two very important documents were generated for the tissues bank of Argentina, Brazil, Colombia, Costa Rica, Cuba, Ecuador, El Salvador, Mexico, Peru, Uruguay and Venezuela, strengthening the interaction among these countries. To offer more radio-sterilized tissues to the medical community, in June of 2007 the RTB signed and agreement with the Secretaria de Salud of the Mexico State by means of the Centro Estatal de Transplantes del Estado de Mexico, for the process of muscle-skeletal tissue, skin and amnion. At present, besides amnion and pig skin, in the RTB there is in existence powdered and chips bone; concluding the validation stage the human skin process is. As a social function of the ININ, the RTB has contributed to the health improvement of patients of more than 50 hospital institutions, mainly those that assist to patient of low resources in different cities of

  20. Study of reactivity of fluidized bed nuclear reactor

    International Nuclear Information System (INIS)

    Rammsy, J.E.M.

    1985-01-01

    The reactor physics calculations of a 19 module Fluidized Bed Nuclear Reactor using Leopard and Odog codes are performed. The behaviour of the reactor was studied by calculating the reactivity of the reactor as a function of the parameters governing the operational and accidental conditions of the reactor. The effects of temperature, pressure, and vapor generation in the core on the reactivity are calculated. Also the start up behaviour of the reactor is analyzed. For the purpose of the study of a prototype research reactor, the calculations on a one module reactor have been performed. (Author) [pt

  1. Tunguska, 1908: the gas pouch and soil fluidization hypothesis

    Science.gov (United States)

    Nistor, I.

    2012-01-01

    The Siberian taiga explosion of 30 June 1908 remains one of the great mysteries of the 20th century: millions of trees put down over an area of 2200 km2 without trace of a crater or meteorite fragments. Hundred years of failed searches have followed, resulting in as many flawed hypothesis which could not offer satisfactory explanations: meteorite, comet, UFO, etc. In the author's opinion, the cause is that the energy the explorers looked for was simply not there! The author's hypothesis is that a meteoroid encountered a gas pouch in the atmosphere, producing a devastating explosion, its effects being amplified by soil fluidization.

  2. Study on transient of fluidized bed nuclear reactor

    International Nuclear Information System (INIS)

    Streck, E.E.

    1988-01-01

    The point kinetic equations for a Fluidized-Bed Nuclear Reactor are solved by the method of Hansen. Due to the time varying nature of the reactor volume, the equations have a non-conventional formulation (moving boundary problem), but the method of solution preserves its asymptotic convergence and efficiency characteristics under this formulation. A one dimensional and linearized thermal hydraulics feedback model was coupled to the point kinetic equations in order to obtain a more realistic representation of the reactor power. The resulting equations are solved by the Euler explicit method. (author)

  3. Product removal and solids transport from fluidized-bed calciners

    International Nuclear Information System (INIS)

    Grimmett, E.S.; Munger, D.H.

    1978-09-01

    Methods of removing the solid product from pilot-plant and production fluidized-bed calciners, and transporting product to underground storage vaults are reported here. Testing of dense-phase solids transport systems in test loops during development of a 15-cm-diam. and 30-cm-diam. calciner are described. A lean-phase solid transport system is used with the Waste Calcining Facility. The results of some recent tests done in a lean-phase transport system connected to the 30-cm-diam. calciner are included in this report

  4. Gasification of sawdust in pressurised internally circulating fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Maartensson, R.; Lindblom, M. [Lund Univ. (Sweden). Dept. of Chemical Engineering

    1996-12-31

    A test plant for pressurised gasification of biofuels in a internally circulating fluidized bed has been built at the department of Chemical Engineering II at the University of Lund. The design performance is set to maximum 20 bar and 1 050 deg C at a thermal input of 100 kW or a maximum fuel input of 18 kg/in. The primary task is to study pressurised gasification of biofuels in relation to process requirements of the IGCC concept (integrated gasification combined cycle processes), which includes studies in different areas of hot gas clean-up in reducing atmosphere for gas turbine applications. (orig.)

  5. Classification of tungsten powder by fluidization method and its application

    International Nuclear Information System (INIS)

    Li Khan-Guan'.

    1989-01-01

    Search for accessible in practice, the technological method to increase the level of control of the granulometric composition of tungsten powder and to increase quality of products and to prepare new materials is carried out. It is shown that the method of fluidization is effective and accessible in practice for tungsten powder (and other refractory metals and compounds) classification, that increases the level of control of the granulometric composition of the powder and thus - its quality, and that improves control of properties of tungsten and other refractory metal products

  6. Determination of viscosity in recirculating fluidized bed using radioactive tracer

    International Nuclear Information System (INIS)

    Silva, G.G. da.

    1986-01-01

    The use of radioactive tracer for measuring viscosity is proposed. The methodology relates the terminal velocity of a radioactive sphere in interior of fluid with the viscosity, which can be a fluidized bed or total flow of solids. The arrangement is composed by two γ detectors placed externally and along the bed. Both detectors are coupled by amplifier to electronic clock. The drop time of sphere between two detectors is measured. The bed viscosity two detectors is measured. The bed viscosity is calculated from mathematical correlations of terminal velocity of the sphere. (M.C.K.)

  7. Single particle behaviour in circulating fluidized bed combustors

    DEFF Research Database (Denmark)

    Erik Weinell, Claus

    1994-01-01

    of fuel particles in a boiler. A cold pilot scale model of a circulating fluidized bed combustor was used. Here sand was recirculated by means of air. Pressure measurements along the riser determined suspension density. A radioactive tracking facility to determined the dynamic picture of the particle...... trajectories in the simulated boiler. In the splash zone, closest to the secondary air inlet an exponential decay in the solids suspension density with the riser height was observed. A transport zone was characterized by an exponential decay in the solids suspension but with a smaller decay constant...

  8. Self-organization and chaos in a fluidized bed

    International Nuclear Information System (INIS)

    Daw, C.S.; Finney, C.E.A.; Vasudevan, M.; van Goor, N.A.; Nguyen, K.; Bruns, D.D.; Kostelich, E.J.; Grebogi, C.; Ott, E.; Yorke, J.A.

    1995-01-01

    We present experimental evidence that a complex system of particles suspended by upward-moving gas can exhibit low-dimensional bulk behavior. Specifically, we describe large-scale collective particle motion referred to as slugging in an industrial device known as a fluidized bed. As gas flow increases from zero, the bulk motion evolves from a fixed point to periodic oscillations to oscillations intermittently punctuated by ''stutters,'' which become more frequent as the flow increases further. At the highest flow tested, the behavior becomes extremely complex (''turbulent'')

  9. Pre-germinated Parboiled Brown Rice Drying Using Fluidization Technique

    OpenAIRE

    Nattapol Poomsa-ad; Lamul Wiset

    2012-01-01

    Pre-germinated parboiled brown rice or Khao hang (in Thai) is paddy which undergoing the processes of soaking, steaming, drying and dehusking to obtain the edible form for consumption. The objectives of this research were to study the kinetic of pre-germinated parboiled brown rice drying using fluidization technique and to study the properties of pre-germinated parboiled brown rice after drying. The dryings were performed at the different temperatures of 110, 120 and 130 oC at the bed depth o...

  10. Coal gasification fluidized bed (Winkler gasification) under pressure

    International Nuclear Information System (INIS)

    Anwer, J.; Boegner, F.

    1976-01-01

    Due to the 'oil crisis', the gasification of lignite and coal for the production of fuel and synthetic gas has reached increased importance. The present state of the Winkler gasification which has successfully operated for a long time is described. After the basic design of a Winkler gasification plant, the various chemical engineering problems are shown: the design characteristics of a fluidized bed, the reaction kinetics, the dependance of the products on the gasification pressure, and the economics of the process. Finally, the development trend in the USA and the future possibility of heating by nuclear heat is dealt with. (orig.) [de

  11. System for the reliability analysis of the electric energy supply; Sistema para el analisis de confiabilidad del suministro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Perales, Favio; Martinez, Javier; Huesca, Francisco; Garcia, Norma; Nieva, Rolando [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    A computer tool, developed for the reliability evaluation of the electric energy supply, considering the faults in the generation and transmission systems, is presented. The application of the tool in planning the expansion and operation of the electric systems, the methodology of the solution employed and the various functions it accounts for, are described. At the end some illustrative examples of its applications by means of the studies with a model of representative characteristics of the interconnected national system. [Espanol] Se presenta una herramienta computacional desarrollada para evaluar la confiabilidad del suministro de energia electrica, considerando las fallas en los sistemas de generacion y transmision. Se describen las aplicaciones de la herramienta en la planeacion de la expansion y de la operacion de sistemas electricos, la metodologia de solucion empleada y las diversas funciones con que cuenta. Al final se presentan algunos ejemplos ilustrativos de sus aplicaciones mediante estudios con un modelo de caracteristicas representativas del sistema interconectado nacional.

  12. Electric energy saving and its impact in the mining industry; El ahorro de energia electrica y su impacto en la industria minera

    Energy Technology Data Exchange (ETDEWEB)

    Urteaga Dufour, Jose Antonio [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE), Mexico, D. F. (Mexico)

    1993-12-31

    In this paper are shown the most important results of the energy diagnosis performed in some representative industries of the mining industry, where opportunity areas were detected in electric energy saving, starting from those measures that do not require investment up to the ones that require medium investment, recoverable in less than two years terms as a maximum and with electric energy saving ranging from 10% to 25%. [Espanol] En este trabajo, se presentan los resultados mas importantes, obtenidos en el diagnostico energetico realizado en algunas empresas representativas de la rama de la mineria, en donde se detectaron areas de oportunidad de ahorro de energia electrica que van desde aquellas medidas que no requieren inversiones hasta las que requieren medianas inversiones, recuperables en menos de dos anos como maximo y con ahorros de energia que van desde un 10% hasta un 25%.

  13. A simple and efficient formula for saving electric energy in lighting systems; Una formula sencilla y eficaz para ahorrar energia electrica en sistemas de iluminacion

    Energy Technology Data Exchange (ETDEWEB)

    Figueroa Noriega, L. R. [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico, Mexico, D. F. (Mexico)

    1995-12-31

    In the Metropolitan Area of Mexico City, as well as in other regions with a similar climate, there are an important number of users of the electric energy service, whose main load consists of lighting, since systems such as environmental conditioning, refrigeration, pumping and others are either not necessary or lack of importance as electric energy consumers. These are classified in the range of small users that altogether represent a significant saving, but the precarious diffusion of the technological advances have not contemplated the need of carrying on corrective actions. Among these users are the offices, sites of entertainment and a range of commerces and services such as clothing stores, pharmacies, shoe stores, printing shops, dry cleaner`s, restaurants, barber shops, etc. The present paper pretends to provide a simple methodology easy to carry on, derived form a demonstrative project that FIDE (Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico) successfully carried out for the Club Deportivo Berinbau. [Espanol] En el area Metropolitana de la ciudad de Mexico, asi como en otras regiones con clima similar, existe un numero importante de usuarios del servicio de energia electrica cuya carga principal consiste en iluminacion, ya que sistemas como acondicionamiento ambiental, refrigeracion, bombeo y otros, o bien no son necesarios o carecen de la importancia en cuanto a consumo de energia electrica. Estos se catalogan dentro del rango de pequenos usuarios que en conjunto representan un potencial de ahorro significativo pero que, debido a la precaria difusion de los adelantos tecnologicos, no han contemplado la posibilidad de llevar a cabo acciones correctivas. Entre estos usuarios se encuentran oficinas, lugares de esparcimiento, planteles educativos y una gama de comercios y servicios como tiendas de ropa, farmacias, zapaterias, imprentas, tintorerias, restaurantes, peluquerias, etc. El presente trabajo pretende proporcionarles una

  14. A microwave technique for electrical conductivity measurements in semiconductors; Un procedimiento en frecuencia de microondas para la medicion de la conductividad electrica en semiconductores

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, A; Zehe, A [Benemerita Universidad Autonoma de Puebla, Puebla (Mexico); Starostenko, O [Universidad de las Americas, Puebla, (Mexico); Perez, L [Benemerita Universidad Autonoma de Puebla, Puebla (Mexico)

    2003-01-15

    In the present paper a theoretical approach is given together with the description of the experimental technique for electrical conductivity measurements of semiconductors in frequency range of 10 GHz, corresponding to a wavelength of {lambda}= 3 cm. It is shown, that the sample conductivity, measured without the need of electrical contacts, Is practically identical with results obtained by direct current methods. The potential use of the method for dielectric measurements in samples of general shape is included in the discussion. Given that the local electrical field is known only in bodies of ellipsoidal shape, one has to apply approximation methods for sample shapes of practical relevance (cylinders, cubes, disks). Finally, the measuring range and corresponding errors are explained on the base of measurements realized with silicon samples. [Spanish] En el presente trabajo se desarrolla la teoria junto con la descripcion del arreglo experimental para la medicion de la conductividad electrica en muestras semiconductoras, utilizando un campo de microondas de {lambda}= 3 cm, correspondiente a una frecuencia n de 10 GHz. Se demuestra que la conductividad electrica medida sin la necesidad de contactos electricos es practicamente identica con resultados obtenidos por el metodo comun utilizando corriente directa (d.c.). Se incorpora en la discusion ademas el potencial del metodo para el estudio de propiedades dielectricas en muestras de geometria general. Dado que solamente en cuerpos con geometria elipsoidal se conoce bien el campo electrico local, y con esto el momento bipolar inducido, para muestras de geometrias mas practicas (cilindros, cubos, discos) se acude a metodos de aproximacion. Finalmente, se discute el rango de mediciones y errores, y se presentan mediciones concretas, utilizando muestras de silicio.

  15. The distribution of the electric energy consumed in the World Trade Center building; La distribucion de la energia electrica consumida en el edificio World Trade Center

    Energy Technology Data Exchange (ETDEWEB)

    Gaona de la Fuente, Alvaro; Carrillo Borja, Angel [Luz y Fuerza del Centro, Mexico, D. F. (Mexico)

    1997-12-31

    This document describes the distribution of the electric energy in the World Trade Center building. Also called the Business International Capital, it is a modern international concept that integrates under the same roof services and supports required by the foreign commerce, with a great 50 stories high building, information network, a business center, a commercial center, an international center for exhibits and conventions and a luxury hotel. It is a modern building equipped with a numberless technological advancements an a total installed electrical load of 35000 kVA. The distribution structures utilized for high buildings are described, the structure that was decided to adopt in the World Trade Center, the requirement for the execution of the distribution electric work, the Luz y Fuerza installations in the buildings conglomerate, the operation and maintenance of the distribution network of this building and the basic needs for new installations of this type of buildings [Espanol] En el presente documento se describe la distribucion de la energia electrica del edificio World Trade Center de la ciudad de Mexico. Llamado tambien la capital internacional de los negocios es un moderno concepto internacional que integra bajo un mismo techo servicios y apoyos que se requieren para el comercio exterior contando con una gran torre de 50 pisos, red de informacion, un centro de negocios, un centro comercial, un centro internacional de exposiciones y convenciones y un hotel de lujo. Es un edificio moderno equipado con un sinnumero de adelantos tecnologicos y con una carga total instalada de 35000 kVA. Se describen las estructuras de distribucion utilizadas en edificios altos, la estructura que se decidio implantar en el World Trade Center, los requerimientos para la ejecucion de la obra electrica de distribucion, las instalaciones de Luz y Fuerza en el conjunto de dicho edificio, la operacion y mantenimiento de la red de distribucion de este edificio, y las necesidades

  16. The relationship of fluidized bed technology to the U.S. Clean Coal Technology demonstration program

    International Nuclear Information System (INIS)

    Weth, G.; Geffken, J.; Huber, D.A.

    1991-01-01

    Fluidized Bed Combustion projects (both AFBCs and PFBCs) have a prominent role in the US DOE Clean Coal Technology (CCT) Program. This program has the successful commercialization of these technologies as its primary objective and this is the basic criterion for government funding and participation in the development and demonstration of the technologies. Under the CCT program the US DOE is actively involved in the development and operation of three Fluidized Bed Technology projects, NUCLA, TIDD, and SPORN, and is in the negotiation stage on others, Dairyland, Nichols and Tallahassee. All of these projects, along with the operating information on fluidized beds in the industrial sector, will provide a basis for evaluating future utilization of Fluidized Bed Technology in the market place. Impacting upon further utilization will be the time-frame and the Clean Air Act Amendments of 1990. This paper presents the results of a study to ascertain the commercial readiness of Fluidized Bed Technology to meet the emissions and time-frame requirements of the Clean Air Act Amendments of 1990. Specifically addressed are: Commercialization criteria/factors which candidate and/or existing CCTs must achieve in order to gain market acceptance. The status of Fluidized Bed Technology in achieving these commercialization criteria for market acceptance (industrial and utility) consistent with the time frame of the Clean Air Act Amendments of 1990. Recommendations of commercialization criteria for future fluidized bed CCT demonstration projects

  17. Thermal stability in a newly designed columnar-conical fluidized bed for combustion of rice husk

    Energy Technology Data Exchange (ETDEWEB)

    Rozainee, M.; Salema, A.A.; Ngo, S.P.; Chye, G.B. [Malaysian Technological Univ., Johor Bahru (Malaysia). Dept. of Chemical Engineering

    2006-07-01

    The effects of fluidizing and liquid propane gas (LPG) flow rates on thermal stability of a fluidized bed were examined. The aim of the study was to hybridize a columnar and conical fluidized bed (CCFB) in order to encourage the combustion of low-calorific fuels such as rice husks. Experiments were conducted to examine the thermal stability of the CCFB. Premixed primary air and liquid propane gas (LPG) was fed into the bed in order to verify its thermal stability. Temperature profiles of the combustor and bed were measured. The impact of the fluidizing velocity and LPG flow rate on the temperature profile was examined in order to analyze the influence of the fluidizing velocity and LPG rate on combustion rates. Results of the study showed that the combustion of the CCFB was sustained at a fluidizing velocity of 1.5 U{sub mf} and at an LPG flow rate of 8 liters per minute. Results of the study showed that fluidizing velocity played an important role on the thermal stability of the bed. It was concluded that the thermal stability of the combustor is sufficient for the CCFB. 13 refs., 2 tabs., 5 figs.

  18. Chaotic behavior in a hydrodynamic model of a fluidized bed reactor

    International Nuclear Information System (INIS)

    Schouten, J.C.; van den Bleek, C.M.

    1991-01-01

    Recent preliminary experimental studies using time-series analysis have demonstrated that the multi-phase flow in fluidized bed reactors can be characterized as chaotic. In the present paper, it is therefore argued that the chaotic time-dependence of fluidization is a characteristic feature which should be included in scaling rules for fluidized bed reactors. For example, the similarity groups applied in dimensionless fluidized bed scaling should be improved by extending them with functions of the relevant numbers from chaos theory, such as the correlation and embedding dimension or the maximum Lyapunov exponent. This requires that the dependence of these numbers on fluidization parameters must be theoretically and experimentally investigated. The concept of chaos in fluidization also requires that the classical, empirically developed, hydrodynamic models that are applied in fluidized bed scaling are amended to include time-dependence, non-linearity as well as a sufficient level of complexity before they can predict any chaotic behavior. An example is given of chaotic behavior generated in the classical counter-current flow model according to Van Deemter by writing the upwards solids velocity as a harmonic oscillating function of time. A low-dimensional strange attractor is found, embedded in two-dimensional phase space, of which the correlation dimension depends on the solids exchange coefficient

  19. Mixing Behaviors of Wet Granular Materials in a Pulsating Fluidized Bed

    Science.gov (United States)

    Lim, Eldin Wee Chuan

    2017-11-01

    The Discrete Element Method combined with Computational Fluid Dynamics was coupled with a capillary liquid bridge force model for computational studies of mixing behaviors in a gas fluidized bed containing wet granular materials. There was a high tendency for wet particles to form large agglomerates within which relative motions between adjacent particles were hindered. This resulted in much lower mixing efficiencies compared with fluidization of dry particles. Capillary liquid bridge forces were on average stronger than both fluid drag forces and particle-particle collision forces. Particle exchange between agglomerates was necessary for mixing to occur during fluidization of wet granular materials but required strong capillary liquid bridge forces to be overcome. When pulsation of the inlet gas flow was applied, voidage waves comprising regions of high and low particle concentration formed within the fluidized bed. This allowed particles to cluster and disperse repeatedly, thus facilitating exchange of particles between agglomerates and promoting mixing of particles throughout the fluidized bed. This points towards the possibility of utilizing pulsed fluidization as an effective means of improving mixing efficiencies in fluidized bed systems containing wet granular materials.

  20. ‘Copiar y pegar’ en investigaciones en el pregrado: haciendo mal uso del Internet

    Directory of Open Access Journals (Sweden)

    Charles Huamaní

    2008-06-01

    Full Text Available Introducción: La ética en el proceso de investigación es un tema poco abordado durante el pregrado, por lo que debe ser analizada para prevenir infracciones que podrían afectar el desarrollo de todo investigador en formación. Objetivo: Determinar las características de copia en los trabajos de investigación realizados durante el pregrado, por estudiantes de Medicina Humana de segundo año. Diseño: Estudio observacional retrospectivo. Lugar: Facultad de Medicina, Universidad Nacional Mayor de San Marcos. Población: la sección de la ‘introducción’ de trabajos de investigación realizados el año 2004 en un curso curricular. Intervenciones: se revisó manualmente las oraciones de la ‘introducción’ de los trabajos, se describen el tipo de copia, el número de trabajos, autores, asesores, párrafos copiados, y el tipo de fuentes de información y de copia. Principales medidas de resultados: frecuencias y porcentajes de oraciones copiadas y tipo de copia. Resultados: Se revisó un total de 24 trabajos de investigación, con un promedio de 6 autores y 2 asesores por trabajo, 23 tenían alguna evidencia de copia electrónica, 8 sólo tenían copia literal; del total de oraciones evaluadas, el 64% corresponde a copia total de oraciones; sólo el 30% de las fuentes copiadas eran publicaciones científicas en línea, el resto son fuentes de acceso público no especializadas. Conclusiones: se describe una alta frecuencia de copia en investigaciones durante el pregrado provenientes de fuentes electrónicas, por lo que es necesario prevenir que se repita en futuras investigaciones al implementar sistemas de búsqueda sistemática de plagio.

  1. INCIDENCIA DE LA INVESTIGACION FORMATIVA EN LOS HORIZONTES EPISTEMOLÓGICOS DE LA CONTABILIDAD

    Directory of Open Access Journals (Sweden)

    Juan C Carriel

    2016-04-01

    Full Text Available El propósito de la investigacion es determinar el uso de la investigacion formativa en el horizonte epistemológico de la contabilidad y analizar los micro-currículos de la carrera de Contabilidad y Auditoria en la Universidad Estatal Península de Santa Elena. Por lo que se refiere a las construccion del conocimiento contable con la teoria del positivismo pragmático, la cual hace énfasis en la objetividad de la ciencias exactas, siendo la contabilidad una ciencia social que ha absorbido este paradigma a la ecuacion contable: Activo igual a Pasivo mas Patrimonio. Sin embargo, esta teoria positivismta no ha sido la mas efectiva, a causa de las diferentes crisis financieras de las empresas: más tarde aprece la teoría crítica, afirmando que el conocimiento debe de estar al servicio de la sociedad y no a un sistema empresarial. Asimismo la teoría interpretativista hermenéutica cuyo estudio se posiciona en el sujeto y métodos cualitativos que intentan comprender y no cuantificar; y la teoría de la complejidad, con énfasis en los actores y los contextos de interaccion y significacion. Por otra parte los horizontes epistemológicos en el eje de la didáctica y pedagogia son los relacionado con la teoría del enfoque de sistemas, el aprendizaje invisible, el pensamiento complejo, la pedagogia crítica y las teorías de neuroaprendizaje. Dichas teorías están en relacion con las orientaciones facilitadas porel Consejo de Educación Superior (CES y a su vez con los docentes y estudiantes, ademas interrelacionados con los contextos, los escenarios, los conocimientos y los saberes. En definitiva la realidad es una entidad compleja y pluridimensional, asi pues el proyecto pedagógico curricular de la carrera debe fundamentar teóricamente las actuales tendencias de la ciencia de la era digital del Siglo XXI con pertinencia en la sociedad ecuatoriana y sobre todo a la interrelacion teoria-práctica de la enseñanza en la formacion de los futuror

  2. Scaling up of the fluidized bed granulation process.

    Science.gov (United States)

    Rambali, B; Baert, L; Massart, D L

    2003-02-18

    The scaling up of a fluidized bed granulation process from small scale to production scale is often done empirically in the pharmaceutical industry. In this study, a more practical and systematic method was developed in order to achieve a similar granule size in the scaled up fluid bed. The scaling up is based on the relative droplet size, and the powder bed moisture content at the end of the spraying cycle. The present study describes the scaling up of the fluidized granulation process from small (5 kg scale) to medium (30 kg scale) and to production fluid bed scale (120 kg scale). The granulation process is scaled up with as target a geometric mean granule size of 400 microm. First, the effect of the relative droplet size on the granule size was investigated in the different fluid beds. The effect of the change in relative droplet size on the granule size was different for each fluid bed. Second, experimental design is applied on the small and the medium fluid scale, and regression models for the granule size are proposed in order to scale up the granulation process on the small to medium scale. The granulation process was also successful by scaling-up to the large fluid bed, considering only the relative droplet size.

  3. Co-combustion of waste materials using fluidized bed technology

    Energy Technology Data Exchange (ETDEWEB)

    M. Lopes; I. Gulyurtlu; P. Abelha; T. Crujeira; D. Boavida; I. Cabrita [INETI-DEECA, Lisbon (Portugal)

    2004-07-01

    There is growing interest in using renewable fuels in order to sustain the CO{sub 2} accumulation. Several waste materials can be used as coal substitutes as long as they contain significant combustible matter, as for example MSW and sewage sludge. Besides the outcome of the energetic valorization of such materials, combustion must be regarded as a pre-treatment process, contributing to the safe management of wastes. Landfilling is an expensive management option and requires a previous destruction of the organic matter present in residues, since its degradation generates greenhouse gases and produces acidic organic leachates. Fluidized bed combustion is a promising technology for the use of mixtures of coal and combustible wastes. This paper presents INETI's experience in the co-combustion of coal with this kind of residues performed in a pilot fluidized bed. Both the RDF (from MSW and sewage sludge) and sewage sludge combustion problems were addressed, relating the gaseous emissions, the behaviour of metals and the leachability of ashes and a comparison was made between co-combustion and mono-combustion in order to verify the influence of the utilization of coal. 9 refs., 1 fig., 3 tabs.

  4. Microwave fluidized-bed detoxification of hazardous waste

    Energy Technology Data Exchange (ETDEWEB)

    Varma, R.

    1991-11-01

    Our ongoing research and development (R D) work focuses on demonstrating the technical feasibility of total detoxification of C1HC'' hazardous waste by using microwave energy. In addition, we investigated the capability of nahacolite for in-bed scavenging of HC1 and found it to be very effective. So far, detoxification of halocarbon vapor and liquid waste forms has been achieved. Microwave energy heats and activates the particulates of silicon carbide (SiC) and promotes chemical interactions, facilitating total detoxification of chlorinated hydrocarbons (TCEs) in an air-stream over SiC-fluidized beds under mild (<600{degrees}) conditions. The SiC promotes surface-enhanced reactions and also is a heating transfer medium. These microwave-assisted processes appear to be extremely energy efficient. The Los Alamos National Laboratory (LANL) team can demonstrate the microwave fluidized bed (MFB) technology for total detoxification of halocarbon waste streams. The technology is applicable for treatment of hazardous waste at DOE sites. 5 refs., 5 figs.

  5. On fluidization of borosilicate glasses in intense radiation fields - 16055

    International Nuclear Information System (INIS)

    Ojovan, Michael; Moebus, Guenter; Tsai, Jim; Cook, Stuart; Yang, Guang

    2009-01-01

    The viscosity is rate-limiting for many processes in glassy materials such as homogenisation and crystallisation. Changes in the viscous flow behaviour in conditions of long-term irradiation are of particular interest for glassy materials used in nuclear installations as well as for nuclear waste immobilising glasses. We analyse the viscous flow behaviour of oxide amorphous materials in conditions of electron-irradiation using the congruent bond lattice model of oxide materials accounting for the flow-mediating role of broken bonds termed configurons. An explicit equation of viscosity was obtained which is in agreement with experimental data for non-irradiated glasses and shows for irradiated glasses, first, a significant decrease of viscosity, and, second, a stepwise reduction of the activation energy of flow. An equation for glass-transition temperature was derived which shows that irradiated glasses have lower glass transition temperatures. Intensive electron irradiation of glasses causes their fluidization due to non-thermal bond breaking and can occur below the glass transition temperature. Due to surface tension forces fluidization of glasses at enough high electron flux densities can result in modification of nano-size volumes and particles such as those experimentally observed under TEM electron beams. (authors)

  6. Cold-Flow Circulating Fluidized-Bed Identification

    Energy Technology Data Exchange (ETDEWEB)

    Parviz Famouri

    2005-07-01

    In a variety of industrial applications, the use of a circulating fluidized bed (CFB) provides various advantages, such as reducing environmental pollution and increasing process efficiency. The application of circulating fluidized bed technology contributes to the improvement of gas-solid contact, reduction of the cross-sectional area with the use of higher superficial velocities, the use of the solids circulation rate as an additional control variable, and superior radial mixing, Grace et al. [1]. In order to improve raw material usage and utility consumption, optimization and control of CFB is very important, and an accurate, real time model is required to describe and quantify the process. Currently there is no accepted way to construct a reliable model for such a complex CFB system using traditional methods, especially at the pilot or industrial scale. Three major obstacles in characterizing the system are: 1) chaotic nature of the system; 2) non-linearity of the system, and 3) number of immeasurable unknowns internal to the system,[2]. Advanced control theories and methods have the ability to characterize the system, and can overcome all three of these obstacles. These methods will be discussed in this report.

  7. Multiscale probability distribution of pressure fluctuations in fluidized beds

    International Nuclear Information System (INIS)

    Ghasemi, Fatemeh; Sahimi, Muhammad; Reza Rahimi Tabar, M; Peinke, Joachim

    2012-01-01

    Analysis of flow in fluidized beds, a common chemical reactor, is of much current interest due to its fundamental as well as industrial importance. Experimental data for the successive increments of the pressure fluctuations time series in a fluidized bed are analyzed by computing a multiscale probability density function (PDF) of the increments. The results demonstrate the evolution of the shape of the PDF from the short to long time scales. The deformation of the PDF across time scales may be modeled by the log-normal cascade model. The results are also in contrast to the previously proposed PDFs for the pressure fluctuations that include a Gaussian distribution and a PDF with a power-law tail. To understand better the properties of the pressure fluctuations, we also construct the shuffled and surrogate time series for the data and analyze them with the same method. It turns out that long-range correlations play an important role in the structure of the time series that represent the pressure fluctuation. (paper)

  8. Fluidized bed gasification of waste-derived fuels.

    Science.gov (United States)

    Arena, Umberto; Zaccariello, Lucio; Mastellone, Maria Laura

    2010-07-01

    Five alternative waste-derived fuels obtained from municipal solid waste and different post-consumer packaging were fed in a pilot-scale bubbling fluidized bed gasifier, having a maximum feeding capacity of 100 kg/h. The experimental runs utilized beds of natural olivine, quartz sand or dolomite, fluidized by air, and were carried out under various values of equivalence ratio. The process resulted technically feasible with all the materials tested. The olivine, a neo-silicate of Fe and Mg with an olive-green colour, has proven to be a good candidate to act as a bed catalyst for tar removal during gasification of polyolefin plastic wastes. Thanks to its catalytic activity it is possible to obtain very high fractions of hydrogen in the syngas (between 20% and 30%), even using air as the gasifying agent, i.e. in the most favourable economical conditions and with the simplest plant and reactor configuration. The catalytic activity of olivine was instead reduced or completely inhibited when waste-derived fuels from municipal solid wastes and aggregates of different post-consumer plastic packagings were fed. Anyhow, these materials have given acceptable performance, yielding a syngas of sufficient quality for energy applications after an adequate downstream cleaning. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  9. Enhanced Productivity of Chemical Processes Using Dense Fluidized Beds

    Energy Technology Data Exchange (ETDEWEB)

    Sibashis Banerjee; Alvin Chen; Rutton Patel; Dale Snider; Ken Williams; Timothy O' Hern; Paul Tortora

    2008-02-29

    The work detailed in this report addresses Enabling Technologies within Computational Technology by integrating a “breakthrough” particle-fluid computational technology into traditional Process Science and Engineering Technology. The work completed under this DOE project addresses five major development areas 1) gas chemistry in dense fluidized beds 2) thermal cracking of liquid film on solids producing gas products 3) liquid injection in a fluidized bed with particle-to-particle liquid film transport 4) solid-gas chemistry and 5) first level validation of models. Because of the nature of the research using tightly coupled solids and fluid phases with a Lagrangian description of the solids and continuum description of fluid, the work provides ground-breaking advances in reactor prediction capability. This capability has been tested against experimental data where available. The commercial product arising out of this work is called Barracuda and is suitable for a wide (dense-to-dilute) range of industrial scale gas-solid flows with and without reactions. Commercial applications include dense gas-solid beds, gasifiers, riser reactors and cyclones.

  10. Analysis of the pressure fluctuations in binary solids circulating fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yong-guo; Tian, Zi-ping; Miao, Zheng-qing [School of Mechanical and Power Engineering, Shanghai JiaoTong University, Dongchuan Road 800, Shanghai 200240 (China)

    2006-03-15

    Pressure fluctuations are often selected to analyze the dynamic changes in the fluidized bed. Many researchers in the field of fluidization have adopted many methods to analyze the pressure signals in fluidized beds, such as statistical analysis (in time domain), frequency analysis (in frequency domain) and non-linear analysis (such as chaotic method). There are many literatures concentrated on statistical analysis in the fluidization field since this method can display the distribution density of the pressure fluctuations. In this study, the pressure fluctuations on the bed wall at different bed heights in the cold two dimensional (2-D) circulating fluidized bed (200x30x1200mm{sup 3}) were sampled. The colophony, millet and 20% millet plus 80% colophony were selected as bed materials. The pressure signals were analyzed by means of statistical methods. The correlation equations between the pressure signals and fluidization parameters were obtained under different operational conditions. Finally, comparisons between the single solid and binary solids 2-D circulating fluidized beds were investigated deeply. Two parameters, K{sub 1} (=0.54(u-u{sub mf}){sup 0.4}h{sup 0.8}/g{sup 0.2}) and K{sub 2} (={sigma}{sub b}/(r{sub s}g(1-{epsilon}{sub mf}))), were selected to characterize the fluidization mechanism. It was found that the relationships between K{sub 2} and K{sub 1} among the single solid and binary solids circulating fluidized beds vary a great deal. (author)

  11. A process to produce effervescent tablets: fluidized bed dryer melt granulation.

    Science.gov (United States)

    Yanze, F M; Duru, C; Jacob, M

    2000-11-01

    The purpose of the present study was to apply melt granulation in a fluidized bed dryer (fluidized bed dryer melt granulation) to manufacture one-step effervescent granules composed of anhydrous citric acid and sodium bicarbonate to make tablets. This study permitted us to establish that such process parameters as concentrations of polyethylene glycol (PEG) 6000, residence times in the fluidized bed dryer, fineness of PEG6000, fineness of initial mixture effervescent systems, and efficiency of two lubricants markedly affect some granule and tablet characteristics. It is a dry process that is simple, rapid, effective, economical, reproducible, and particularly adapted to produce effervescent granules that are easily compressed into effervescent tablets.

  12. A comparison of granules produced by high-shear and fluidized-bed granulation methods.

    Science.gov (United States)

    Morin, Garett; Briens, Lauren

    2014-08-01

    Placebo granules were manufactured by both wet high-shear and fluidized-bed techniques. The granules were compared based on size, shape, surface morphology, and a variety of different flowability measurements. This comparison showed that granule formation and growth were different, with induction growth for high-shear granulation and steady growth for fluidized-bed granulation. Final granules from high-shear granulation were more spherical and dense compared with the irregular granules from fluidized-bed granulation. The high-shear granules demonstrated better overall flow properties.

  13. Fluidized bed spray granulation: analysis of heat and mass transfers and dynamic particle populations

    Directory of Open Access Journals (Sweden)

    S. Heinrich

    2005-06-01

    Full Text Available A model was developed taking into consideration the heat and mass transfer processes in liquid-sprayed fluidized beds. Such fluidized beds (FB are used for granulation, coating and agglomeration. Conclusions are drawn on the relevance of particle dispersion, spraying and drying to temperature and concentrations distributions. In extension, the model was coupled with a population balance model to describe the particle size distribution and the seeds formation for continuous external FBSG (fluidized bed spray granulation with non-classifying product discharge and a screening and milling unit in the seeds recycle. The effects of seeds formation on the stability of the process is discussed.

  14. Bioreactors with Light-Beads Fluidized Bed: The Voidage Function and its Expression

    Directory of Open Access Journals (Sweden)

    Iliev Vasil

    2014-12-01

    Full Text Available Light-beads fluidized bed bioreactors with gel particles are an attractive alternative for the implementation of a system with immobilized cells. They have a number of advantages: soft operating conditions, ability to work in an ideal mixing regime, intensification of heat- and mass transfer processes in the fermentation system. The expansion characteristics of the fluidized bed were investigated in the present work. The fluidized bed expansion was described using the voidage function. It was found that the voidage can be described by nonlinear regression relationships and the regression coefficients were a function of the particles parameters.

  15. Calidad de vida en la salud: algunas investigaciones en el ámbito hospitalario

    Directory of Open Access Journals (Sweden)

    Ma. Ángeles Pérez San Gregorio

    2005-01-01

    Full Text Available Exponemos los resultados más relevantes de dos investigaciones relacionadas con la Calidad de Vida en la Salud. En la primera de ellas, empleamos tres grupos con 32 sujetos cada uno: pacientes con Enfermedad Pulmonar Obstructiva Crónica (EPOC estabilizados, pacientes con EPOC descompensados (hospitalizados y enfermos con cáncer de pulmón (hospitalizados. Analizamos la influencia de la descompensación de la EPOC sobre la calidad de vida. En la segunda investigación, empleamos un grupo de 57 familiares de pacientes traumatizados graves que fueron evaluados en dos momentos diferentes: cuando el paciente se hallaba ingresado en la UCI y transcurridos cuatro años del alta de éste. Analizamos cómo afecta en los familiares (variables clínicas de personalidad, relaciones familiares y temor experimentado ante la muerte el tiempo transcurrido desde el ingreso del paciente en la UCI en función de su calidad de vida.

  16. CALIDAD DE VIDA EN LA SALUD: ALGUNAS INVESTIGACIONES EN EL ÁMBITO HOSPITALARIO

    Directory of Open Access Journals (Sweden)

    Antonio Galán Rodríguez

    2005-06-01

    Full Text Available Exponemos los resultados más relevantes de dos investigaciones relacionadas con la Calidad de Vida en la Salud. En la primera de ellas, empleamos tres grupos con 32 sujetos cada uno: pacientes con Enfermedad Pulmonar Obstructiva Crónica (EPOC estabilizados, pacientes con EPOC descompensados (hospitalizados y enfermos con cáncer de pulmón (hospitalizados. Analizamos la influencia de la descompensación de la EPOC sobre la calidad de vida. En la segunda investigación, empleamos un grupo de 57 familiares de pacientes traumatizados graves que fueron evaluados en dos momentos diferentes: cuando el paciente se hallaba ingresado en la UCI y transcurridos cuatro años del alta de éste. Analizamos cómo afecta en los familiares (variables clínicas de personalidad, relaciones familiares y temor experimentado ante la muerte el tiempo transcurrido desde el ingreso del paciente en la UCI en función de su calidad de vida.

  17. El foro romano de Iuliobriga (Cantabria: nuevas investigaciones arqueológicas

    Directory of Open Access Journals (Sweden)

    Cepeda Ocampo, Juan José

    2009-12-01

    Full Text Available This article offers a general interpretation of Iuliobriga’s forum, emphasizing its characteristics and peculiarities from the information obtained in the latest archaeological research. It focuses on the results of an excavation made in 2004 inside the church of Santa María in Retortillo. This archaeological dig has allowed us to broaden the view we had of the forum’s square, thanks to the discovery of a new functional space inside it. The archaeological research has also revealed information about the origin of the habitat in Iuliobriga and permits the forum to be dated with certainty in the Flavian period.Se ofrece una interpretación general del foro de Iuliobriga, destacando sus características y peculiaridades tras la información obtenida en las últimas investigaciones arqueológicas. En especial, se presentan los resultados de una excavación realizada en 2004 en el interior de la iglesia de Santa María de Retortillo, la cual ha permitido ampliar la visión que se tenía de la plaza porticada del foro, con el descubrimiento de un nuevo espacio funcional dentro de éste. La misma intervención arqueológica ha aportado datos sobre el origen del hábitat en Iuliobriga y sobre la datación flavia del conjunto monumental del foro.

  18. Optimización de la gerencia en investigaciones de postgrado

    Directory of Open Access Journals (Sweden)

    Elizabeth Valarino

    1996-01-01

    Full Text Available El estudio de los procesos de elaboración de investigaciones es una línea de estudio que se adelanta de manera conjunta en varias universidades, dado el bajo índice de graduados que se presenta en la mayoría de los Programas de Postgrado. Se presentan los resultados de un estudio que identifica y compara las variables principales que se asocian al éxito o riesgo en la productividad de proyectos de investigación, especialmente trabajos de grado y tesis. Se agrupan en 4 áreas principales: Supervisor del Proyecto, Investigador, Relación entre ambos y Sistemas de Apoyo Institucional. Un Cuestionario construido con base en sus dimensiones y categorías, es aplicado a los participantes principales de un programa de postgrado (estudiantes tesistas y profesores tutores y sus resultados comparativos se analizan de acuerdo a 4 escalas (logro, deseabilidad, discrepancia y consenso, los índices de criticidad y la Jerarquía crítica resultante. El modelo de análisis yel instrumento propuesto ha sido de utilidad en varias instituciones académicas para efectuar análisis de programas de postgrado y proponer los cambios necesarios. Se derivan recomendaciones para optimizar el proceso gerencial de elaboración de Proyectos de Investigación en los Postgrados.

  19. Introduction criteria and concepts on energy saving in the technical standards for electric installations; Introduccion de criterios y conceptos de ahorro de energia en las normas tecnicas para instalaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Rincon Nader, Jorge A. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1992-12-31

    The project Introduction Criteria and Concepts on Energy Saving in the Technical Standards for electric installations, is described, whose immediate objective is to recommend and in some cases regulate the use of energy saving equipment and devices and the adoption of attitudes and procedures that convey into saving, and the rational and efficient use of the electric energy. [Espanol] Se describe el proyecto Introduccion de Criterios y Conceptos de Ahorro de Energia en las Normas Tecnicas para instalaciones electricas, que tiene como objetivo inmediato recomendar, y en algunos casos reglamentar el uso de equipos y dispositivos ahorradores y la adopcion de actitudes y procedimientos que conduzcan a un ahorro y uso racional y eficiente de la energia electrica.

  20. Methodology for the electric energy distribution systems planning of small and rural zones of Comision Federal de Electricidad; Metodologia para la planeacion de sistemas de distribucion de energia electrica de zonas pequenas y rurales de Comision Federal de Electricidad

    Energy Technology Data Exchange (ETDEWEB)

    Ochoa Gomez, Miguel Armando

    2008-12-15

    institutional procedures, the standards, the commercial programs and the programs developed by the Management of Planning, used in the CFE to make the electric distribution systems planning. In the same way, in Chapter 4 a methodology for the optimization of the electrical grids in low tension is proposed, standing out some errors that are commonly committed in the design of these types of networks, doing recommendations to correct them with low cost investments. Because of the importance in the design of medium tension lines, in Chapter 3 the set of economic conductors for 23 kV was determined for urban and rural areas, system type A (3F-4H, 2F-3H, 1F-2H), by means of the Modified Method. With this information we will be able to select the conductor that offers the best economy in the time, in each extension of the network. In Chapter 5 the proposed methodology in the planning of the electrical system of distribution of the Zapotlan Zone was applied, as much in substations as in the high and medium tension network. In this chapter analyses of optimization of the network were performed, capacitor banks application, attention to the incremental demand, power losses, contingencies by fault and reliability of the provision. Finally the obtained conclusions of the investigation and the work carried out are presented; as well as the recommendations for future facilities. [Spanish] Las 13 Divisiones de Distribucion en las cuales la Comision Federal de Electricidad (CFE) tiene estructurada, administrativa y tecnicamente, la distribucion de la energia electrica en su territorio atendido, estan constituida a su vez por un total de 120 Zonas de Distribucion, clasificadas conforme al producto de su numero de clientes, por su volumen de ventas anuales, en media y baja tension, como zonas tipo I, II y III. Ejemplos de zonas tipo III son las Zona Guadalajara y la Zona Metropolitana Monterrey Norte, Oriente y Poniente (metropolis), la tipo II son zonas predominantemente urbanas como Queretaro

  1. Scale-up of an electrical capacitance tomography sensor for imaging pharmaceutical fluidized beds and validation by computational fluid dynamics

    Science.gov (United States)

    Wang, Haigang; Yang, Wuqiang

    2011-10-01

    The aim of this research is to apply electrical capacitance tomography (ECT) in pharmaceutical fluidized beds and scale up the application of ECT from a lab-scale fluidized bed to a production-scale fluidized bed. The objective is to optimize the design of the production-scale fluidized bed and to improve the operation efficiency of the fluidization processes. This is the first time that ECT has been scaled up to a production-scale fluidized bed of 1.0 m diameter and batch process capacity of 100 kg in a real industrial environment. With a large-scale fluidized bed in a real industrial environment, some key issues on the ECT sensor design must be addressed. To validate ECT measurement results, a two-phase flow model has been used to simulate the process in a lab-scale and pilot-scale fluidized bed. The key process parameters include solid concentration, average concentration profiles, the frequency spectrum of signal fluctuation obtained by the fast Fourier transfer (FFT) and multi-level wavelet decomposition in the time domain. The results show different hydrodynamic behaviour of fluidized beds of different scales. The time-averaged parameters from ECT and computational fluid dynamics are compared. Future work on the ECT sensor design for large-scale fluidized beds are given in the end of the paper.

  2. Combustion en lit fluidisé Fluidized-Bed Combustion

    Directory of Open Access Journals (Sweden)

    Chrysostome G.

    2006-11-01

    Full Text Available Après quelques rappels généraux sur la fluidisation où seront présentés en par-ticulier les avantages qu'elle offre en combustion, on exposera l'état actuel du développement des générateurs à lit fluidisé opérant avec les combustibles suivants : charbon, combustibles pétroliers, résidus divers ; il sera fait mention de la contribution de l'Institut Français du Pétrole (IFP dans les deux derniers domaines.On présentera ensuite les installations les plus récentes en traitement de minerais (grillage des sulfures, calcination de calcaires. En raison de son importance on examinera encore les possibilités de désulfuration au sein de lits fluidisés, de même que seront commentés les travaux de régénération des absorbants.On terminera enfin en mentionnant les développements des lits circulants ou rapides, considérés comme les réacteurs de la seconde génération. After a general review of fluidization including in particular the advantages it offers for combustion, this article describes the present state of the development of fluidized-bed gcnerators operating with the following fuels : cool, petroleum fuels, different residues. Mention is made of Institut Français du Pétrole (IFP contribution in the last two fields. Then the most recent ore-treating installations are described (roasting of sulfides, calcination of limestones. Because of its importance, the possibilities of desulfurizoticn inside fluidized beds is examined, and research on the regeneration of absorbants is commented on. The article ends by mentioning the development of circulating or fast beds which are considered as second generation reactors.

  3. A review of oxy-fuel combustion in fluidized bed reactors

    CSIR Research Space (South Africa)

    Mathekga, HI

    2016-06-01

    Full Text Available Presently, there is no detailed review that summarizes the current knowledge status on oxy-fuel combustion in fluidized bed combustors. This paper reviewed the existing literature in heat transfer, char combustion and pollutant emissions oxy...

  4. Fluidized bed pyrolysis of bitumen-impregnated sandstone at sub-atmospheric conditions

    Energy Technology Data Exchange (ETDEWEB)

    Fletcher, J.V.; Deo, M.D.; Hanson, F.V.

    1993-01-01

    A 15.2 cm diameter fluidized bed reactor was designed, built, and operated to study the pyrolysis of oil sands at pressures slightly less than atmospheric. Fluidizing gas flow through the reactor was caused by reducing the pressure above the bed with a gas pump operating in the vacuum mode. Pyrolysis energy was supplied by a propane burner, and the hot propane combustion gases were used for fluidization. The fluidized bed pyrolysis at reduced pressure using combustion gases allowed the reactor to be operated at significantly lower temperatures than previously reported. At 450[degree], over 80% of the bitumen fed was recovered as a liquid product, and the spent sand contained less than 1% coke. The liquid product recovery system, by design, yielded three liquid streams with distinctly different properties.

  5. Fluidized bed pyrolysis of bitumen-impregnated sandstone at sub-atmospheric conditions

    Energy Technology Data Exchange (ETDEWEB)

    Fletcher, J.V.; Deo, M.D.; Hanson, F.V.

    1993-03-01

    A 15.2 cm diameter fluidized bed reactor was designed, built, and operated to study the pyrolysis of oil sands at pressures slightly less than atmospheric. Fluidizing gas flow through the reactor was caused by reducing the pressure above the bed with a gas pump operating in the vacuum mode. Pyrolysis energy was supplied by a propane burner, and the hot propane combustion gases were used for fluidization. The fluidized bed pyrolysis at reduced pressure using combustion gases allowed the reactor to be operated at significantly lower temperatures than previously reported. At 450{degree}, over 80% of the bitumen fed was recovered as a liquid product, and the spent sand contained less than 1% coke. The liquid product recovery system, by design, yielded three liquid streams with distinctly different properties.

  6. Mathematical modeling of a fluidized bed rice husk gasifier: Part 3 -- Model verification

    Energy Technology Data Exchange (ETDEWEB)

    Mansaray, K.G.; Ghaly, A.E.; Al-Taweel, A.M.; Ugursal, V.I.; Hamdullahpur, F.

    2000-04-01

    The validity of the two-compartment model developed for fluidized bed gasification of biomass was tested using experimental data obtained from a dual-distributor-type fluidized bed gasifier. The fluidized bed was operated on rice husks at various bed heights (19.5, 25.5, and 31.5 cm), fluidization velocities (0.22, 0.28, and 0.33 m/s), and equivalence ratios (0.25, 0.30, and 0.35). The model gave reasonable predictions of the core, annulus, and exit temperatures as well as the mole fractions of the combustible gas components and product gas higher heating value, except for the overall carbon conversion, which was overestimated. This could be attributed to uncertainties in the sampling procedure.

  7. Mathematical modeling of a fluidized bed rice husk gasifier: Part 3 - Model verification

    Energy Technology Data Exchange (ETDEWEB)

    Mansaray, K.G.; Ghaly, A.E.; Al-Taweel, A.M.; Ugursal, V.I.; Hamdullahpur, F.

    2000-03-01

    The validity of the two-compartment model developed for fluidized bed gasification of biomass was tested using experimental data obtained from a dual-distributor-type fluidized bed gasifier. The fluidized bed was operated on rice husks at various bed heights (19.5, 25.5, and 31.5 cm), fluidization velocities (0.22, 0.28, and 0.33 m/s), and equivalence ratios (0.25, 0.30, and 0.35). The model gave reasonable predictions of the core, annulus, and exit temperatures as well as the mole fractions of the combustible gas components and product gas higher heating value, except for the overall carbon conversion, which was overestimated. This could be attributed to uncertainties in the sampling procedure. (Author)

  8. Operating experience and data on revolving type fluidized bed incineration plants

    International Nuclear Information System (INIS)

    Nakayama, J.

    1990-01-01

    In refuse incinerators operating by revolving fluidization (Revolving Type Fluidized Bed Incinerator) a broad range of wastes, from low caloric refuse of high moisture content to high caloric value material including a wide variety of plastics, can be incinerated at high efficiency because the unit is outstanding in terms of distribution of waste in the incinerator bed and uniformity of heat. In addition, its vigorous revolving fluidization action is very effective in pulverizing refuse, so even relatively strict emission standards can be met without fine pre-shredding. Residues are discharged in a clean, dry form free of putrescible material. Data on practical operation of the revolving fluidized bed incinerator are presented in this paper

  9. A grid-independent EMMS/bubbling drag model for bubbling and turbulent fluidization

    DEFF Research Database (Denmark)

    Luo, Hao; Lu, Bona; Zhang, Jingyuan

    2017-01-01

    The EMMS/bubbling drag model takes the effects of meso-scale structures (i.e. bubbles) into modeling of drag coefficient and thus improves coarse-grid simulation of bubbling and turbulent fluidized beds. However, its dependence on grid size has not been fully investigated. In this article, we adopt...... a periodic domain show the new drag model is less sensitive to grid size because of the additional dependence on local slip velocity. When applying the new drag model to simulations of realistic bubbling and turbulent fluidized beds, we find grid-independent results are easier to obtain for high......-velocity turbulent fluidized bed cases. The simulation results indicate that the extended EMMS/bubbling drag model is a potential method for coarse-grid simulations of large-scale fluidized beds....

  10. Numerical simulation of a full-loop circulating fluidized bed under different operating conditions

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yupeng [National Energy Technology Lab. (NETL), Morgantown, WV (United States); Musser, Jordan M. [National Energy Technology Lab. (NETL), Morgantown, WV (United States); Li, Tingwen [National Energy Technology Lab. (NETL), Morgantown, WV (United States); AECOM, Morgantown, WV (United States); Rogers, William A. [National Energy Technology Lab. (NETL), Morgantown, WV (United States)

    2017-10-17

    Both experimental and computational studies of the fluidization of high-density polyethylene (HDPE) particles in a small-scale full-loop circulating fluidized bed are conducted. Experimental measurements of pressure drop are taken at different locations along the bed. The solids circulation rate is measured with an advanced Particle Image Velocimetry (PIV) technique. The bed height of the quasi-static region in the standpipe is also measured. Comparative numerical simulations are performed with a Computational Fluid Dynamics solver utilizing a Discrete Element Method (CFD-DEM). This paper reports a detailed and direct comparison between CFD-DEM results and experimental data for realistic gas-solid fluidization in a full-loop circulating fluidized bed system. The comparison reveals good agreement with respect to system component pressure drop and inventory height in the standpipe. In addition, the effect of different drag laws applied within the CFD simulation is examined and compared with experimental results.

  11. Evaluation of the reliability of electric power transmission systems; Evaluacion de confiabilidad de sistemas de transmision de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Vega Ortiz, Miguel

    1989-07-01

    algorithm in a digital program, this was proved in a personal computer applying it to IEEE transmission systems evaluated with other methods, among them one of 140 buses and 199 transmission lines. The results as far as reliability indexes compared with the other methods were very satisfactory and promising as far as required CPU time and memory for larger systems. [Spanish] En esta tesis se ataca el problema de la Evaluacion de la Confiabilidad de los Sistemas de Transmision de Energia Electrica para fines de su planeacion integral. Una vez descrito el problema se presentan los indices que miden la confiabilidad de los sistemas electricos de potencia. Despues se describen los metodos para evaluar las redes de transmision, como el de Enumeracion de Contingencias, el Monte Carlo, el de Markov y los metodos para sistemas complejos como el de Cortes Minimos. Este ultimo se desarrolla ampliamente por las ventajas que presenta su aplicacion en la planeacion de redes grandes y complejas. El metodo de cortes minimos consta de dos grandes pasos: Determinar los cortes minimos para los puntos de carga y calcular los indices de confiabilidad en base a los cortes minimos. Los algoritmos convencionales para la determinacion de cortes minimos consideran un problema por cada punto de carga en forma independiente pasando por una determinacion de caminos minimos. En este tipo de algoritmos el tiempo de CPU y el espacio en memoria requeridos crecen exponencialmente para el caso de sistemas de transmision grandes, lo que representa una fuerte restriccion para su aplicacion. Para resolver este problema se establecio una metodologia en la que se modela el sistema por medio de un grafo y se determinan los cortes minimos con un algoritmo basado en la construccion de ciclos en el grafo dual. Con estos cortes se evalua la conexidad y capacidad de la red, obteniendose los indices de confiabilidad para cada bus y para el sistema. Estos indices se calculan con la representacion equivalente para

  12. Granulation of acetaminophen by a rotating fluidized-bed granulator.

    Science.gov (United States)

    Kawaguchi, T; Sunada, H; Yonezawa, Y; Danjo, K; Hasegawa, M; Makino, T; Sakamoto, H; Fujita, K; Tanino, T; Kokubo, H

    2000-01-01

    The purpose of this research was to evaluate the use of a rotating fluidized-bed granulator to produce acetaminophen granules with sufficient binding force between particles and good plasticity in tablets. Ethenzamide and ascorbic acid were used to compare the relationship between granulation and the sample wetness. It was revealed that a blade rotation rate of 300 rpm, inlet air flow rate of 42 m3/hr, and spraying pressure of 1.5 kg/cm3 produced tablets with the best properties. The granule and tablet properties of ethenzamide and ascorbic acid were compared to those of acetaminophen. These compounds showed different wetting behaviors with water and different compression behaviors. With an increase in medicament content, tablet hardness increased except for the ascorbic acid formulation. Capping and sticking were observed in acetaminophen and in ascorbic acid, respectively, and acetaminophen and ethenzamide showed prolonged disintegration time.

  13. Computational Fluid Dynamics Simulation of Fluidized Bed Polymerization Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Rong [Iowa State Univ., Ames, IA (United States)

    2006-01-01

    Fluidized beds (FB) reactors are widely used in the polymerization industry due to their superior heat- and mass-transfer characteristics. Nevertheless, problems associated with local overheating of polymer particles and excessive agglomeration leading to FB reactors defluidization still persist and limit the range of operating temperatures that can be safely achieved in plant-scale reactors. Many people have been worked on the modeling of FB polymerization reactors, and quite a few models are available in the open literature, such as the well-mixed model developed by McAuley, Talbot, and Harris (1994), the constant bubble size model (Choi and Ray, 1985) and the heterogeneous three phase model (Fernandes and Lona, 2002). Most these research works focus on the kinetic aspects, but from industrial viewpoint, the behavior of FB reactors should be modeled by considering the particle and fluid dynamics in the reactor. Computational fluid dynamics (CFD) is a powerful tool for understanding the effect of fluid dynamics on chemical reactor performance. For single-phase flows, CFD models for turbulent reacting flows are now well understood and routinely applied to investigate complex flows with detailed chemistry. For multiphase flows, the state-of-the-art in CFD models is changing rapidly and it is now possible to predict reasonably well the flow characteristics of gas-solid FB reactors with mono-dispersed, non-cohesive solids. This thesis is organized into seven chapters. In Chapter 2, an overview of fluidized bed polymerization reactors is given, and a simplified two-site kinetic mechanism are discussed. Some basic theories used in our work are given in detail in Chapter 3. First, the governing equations and other constitutive equations for the multi-fluid model are summarized, and the kinetic theory for describing the solid stress tensor is discussed. The detailed derivation of DQMOM for the population balance equation is given as the second section. In this section

  14. Nucla circulating atmospheric fluidized bed demonstration project. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1991-10-01

    Colorado-Ute Electric Association began a study to evaluate options for upgrading and extending the life of its Nucla power station in 1982. Located in southwestern Colorado near the town of Nucla, this station was commissioned in 1959 with a local bituminous coal as its design fuel for three identical stoker-fired units, each rated at 12.6 MW(e). Poor station efficiency, high fuel costs, and spiraling boiler maintenance costs forced the Nucla Station into low priority in the CUEA dispatch order as early as 1981. Among the options CUEA considered was to serve as a host utility to demonstrate Atmospheric Fluidized Bed Combustion (AFBC) technology. The anticipated environmental benefits and apparent attractive economics of a circulating AFBC led to Colorado-Ute`s decision to proceed with the design and construction of a demonstration project in 1984 at the Nucla facility.

  15. Anaerobic degradation of linear alkylbenzene sulfonate in fluidized bed reactor

    Directory of Open Access Journals (Sweden)

    L. L. Oliveira

    2010-12-01

    Full Text Available An anaerobic fluidized bed reactor was used to assess the degradation of the surfactant linear alkylbenzene sulfonate (LAS. The reactor was inoculated with sludge from an UASB reactor treating swine wastewater and was fed with a synthetic substrate supplemented with LAS. Sand was used as support material for biomass immobilization. The reactor was kept in a controlled temperature chamber (30±1 ºC and operated with a hydraulic retention time (HRT of 18 h. The LAS concentration was gradually increased from 8.2±1.3 to 45.8±5.4 mg.L-1. The COD removal was 91%, on average, when the influent COD was 645±49 mg.L-1. The results obtained by chromatographic analysis showed that the reactor removed 93% of the LAS after 270 days of operation.

  16. Application of fluidization to separate packaging waste plastics.

    Science.gov (United States)

    Carvalho, M Teresa; Ferreira, Célia; Portela, Antía; Santos, João Tiago

    2009-03-01

    The objective of the experimental work described in this paper is the study of the separation of PS (polystyrene) from PET (polyethylene terephthalate) and PVC (polyvinyl chloride) from drop-off points using a fluidized bed separator. This is a low-cost process commonly used in the hydro-classification of mineral ores. Firstly, experimental tests were carried out with artificial granulated samples with different grain sizes, types and sources of plastic ("separability tests"). The particle settling velocities were determined under different operating conditions. Then, based on the results, the laboratory tests continued with real mixtures of waste plastics ("separation tests") and the efficiency of the process was evaluated. From a PET-rich mixture, a concentrate of PS with a 75% grade in PS was produced while the underflow was quite clear from PS (grade less than 0.5% in PS).

  17. Bubbling fluidized bed boiler for Vanaja power plant

    Energy Technology Data Exchange (ETDEWEB)

    Sormunen, R.; Haermae, P.; Vessonen, K.; Ketomaeki, A. [ed.

    1998-07-01

    At the Vanaja Power Plant, on the outskirts of Haemeenlinna, there have been changes which reflect the central goals in IVO`s product development work. At Vanaja, efficiency is combined with environmental friendliness. In the early 1980s, the plant was modernized to produce district heat in addition to electricity. At that time, along with the new gas turbine at the plant, the main fuel, coal, while remaining the fuel for the old boilers, was replaced by natural gas. This year a new type of bubbling fluidized bed boiler enabling continuous use of peat and trial use of biofuels along with coal was introduced at the plant. In addition to the Nordic countries, this kind of technology is required in central eastern Europe, where modernization of ageing power plants is being planned to achieve the best possible solutions in respect of production and the environment. IVO develops a new repair technique for underwater sites

  18. Fluidized bed incineration of a slurry waste from caprolactam production

    Energy Technology Data Exchange (ETDEWEB)

    Cammarota, A.; D' Amore, M.; Donsi, G.; Massimilla, L.

    1980-08-01

    Caprolactam tails are a slurry waste produced in the SNIA process for the synthesis of caprolactam. They contain about 65% water, 25% ash and 10% combustible matter. The ashes are low melting, due to the presence of sodium compounds. The incineration of this waste is carried out at temperatures below 600/sup 0/C in beds of silica sand, using a laboratory scale apparatus with a 40 mm ID fluidization column. Variables investigated include sand particle size, slurry flow rate, bed temperature, bed height. The concentrations of CO/sub 2/ and CO are determined continuously in the flue gases. Bed solids are sampled periodically to determine the carbon content. Results of experiments show that the low temperature incineration on a bed of inert solids is a useful technique for the disposal of caprolactam tails. 8 refs.

  19. Technical evaluation: pressurized fluidized-bed combustion technology

    Energy Technology Data Exchange (ETDEWEB)

    Miller, S A; Vogel, G J; Gehl, S M; Hanway, Jr, J E; Henry, R F; Parker, K M; Smyk, E B; Swift, W M; Podolski, W F

    1982-04-01

    The technology of pressurized fluidized-bed combustion, particularly in its application to a coal-burning combined-cycle plant, is evaluated by examining the technical status of advanced-concept plant components - boiler system (combustor, air-handling and air-injection equipment, and heat exchangers); solids handling, injection, and ejection system; hot-gas cleanup equipment; instrumentation/control system; and the gas turbine - along with materials of plant construction. Environmental performance as well as energy efficiency are examined, and economic considerations are reviewed briefly. The evaluation concludes with a broad survey of the principal related research and development programs in the United States and other countries, a foreview of the most likely technological developments, and a summary of unresolved technical issues and problems.

  20. Development of second-generation pressurized fluidized bed combustion process

    Energy Technology Data Exchange (ETDEWEB)

    Wolowodiuk, W.; Robertson, A. [Foster Wheeler Development Corp., Livingston, NJ (United States); Bonk, D. [Dept. of Energy, Morgantown, WV (United States)

    1995-12-01

    Under the sponsorship of the United States Department of Energy, Foster Wheeler Development Corporation, and its team members, Westinghouse, Gilbert/Commonwealth, and the Institute of Gas Technology are developing second-generation pressurized fluidized bed combustion technology capable of achieving net plant efficiency in excess of 45 percent based on the higher heating value of the coal. A three-phase program entails design and costing of a 500 MWe power plant and identification of developments needed to commercialize this technology (Phase 1), testing of individual components (Phase 2), and finally testing these components in an integrated mode (Phase 3). This paper briefly describes the results of the first two phases as well as the progress on the third phase. Since other projects which use the same technology are in construction or in negotiation stages-namely, the Power System Development Facility and the Four Rivers Energy Modernization Projects-brief descriptions of these are also included.

  1. A numerical model of a fluidized bed biomass gasifier

    Energy Technology Data Exchange (ETDEWEB)

    Hongming Jiang; Morey, R.V. (Minnesota Univ., St. Paul, MN (United States). Dept. of Agricultural Engineering)

    1992-01-01

    A one-dimensional, steady state, numerical model was developed for a fluidized bed biomass gasifier. The gasifier model consists of a fuel pyrolysis model, an oxidation model, a gasification model and a freeboard model. Given the bed temperature, ambient air flow rate and humidity ratio, fuel moisture content and reactor parameters, the model predicts the fuel feed rate for steady state operation, composition of the producer gas and fuel energy conversion. The gasifier model was validated with experimental results. The effects of major mechanisms (fuel pyrolysis and the chemical and the physical rate processes) were assessed in a sensitivity study of the gasification model. A parametric study was also conducted for the gasifier model. It is concluded that the model can be used for gasifier performance analysis. (author)

  2. Acoustic monitoring of a fluidized bed coating process

    DEFF Research Database (Denmark)

    Naelapaa, Kaisa; Veski, Peep; Pedersen, Joan G.

    2007-01-01

      The aim of the study was to investigate the potential of acoustic monitoring of a production scale fluidized bed coating process. The correlation between sensor signals and the estimated amount of film applied and percentage release, respectively, were investigated in coating potassium chloride...... (KCl) crystals with ethylcellulose (EC). Vibrations were measured with two different types of accelerometers. Different positions for placing the accelerometers and two different product containers were included in the study. Top spray coating of KCl was chosen as a ‘worst case' scenario from a coating...... point perspective. The acoustic monitoring has the potential of summarising the commonly used means to monitor the coating process. The best partial least squares (PLS) regressions, obtained by the high frequency accelerometer, showed for the release a correlation coefficient of 0.92 and a root mean...

  3. Acoustic fluidization and the scale dependence of impact crater morphology

    Science.gov (United States)

    Melosh, H. J.; Gaffney, E. S.

    1983-01-01

    A phenomenological Bingham plastic model has previously been shown to provide an adequate description of the collapse of impact craters. This paper demonstrates that the Bingham parameters may be derived from a model in which acoustic energy generated during excavation fluidizes the rock debris surrounding the crater. Experimental support for the theoretical flow law is presented. Although the Bingham yield stress cannot be computed without detailed knowledge of the initial acoustic field, the Bingham viscosity is derived from a simple argument which shows that it increases as the 3/2 power of crater diameter, consistent with observation. Crater collapse may occur in material with internal dissipation Q as low as 100, comparable to laboratory observations of dissipation in granular materials. Crater collapse thus does not require that the acoustic field be regenerated during flow.

  4. La competencia sobre planificación de investigaciones en 4º de ESO: un estudio de caso

    Directory of Open Access Journals (Sweden)

    Iñigo RODRÍGUEZ ARTECHE

    2016-01-01

    Full Text Available En los últimos años, las metodologías de tipo “Inquiry-Based Science Education” (IBSE se vienen recomendando desde las instancias europeas para mejorar los niveles de competencia y las actitudes hacia la ciencia de los estudiantes. Así, el presente estudio pretende comprobar la eficacia de una metodología IBSE, la Metodología de Resolución de Problemas como Investigación (MRPI, para la enseñanza-aprendizaje de la competencia sobre planificación de investigaciones en 4º de ESO. Para ello, a partir de las resoluciones de problemas abiertos de los estudiantes, se analiza el progreso en el aprendizaje de las dimensiones competenciales relativas a la planificación de investigaciones y la influencia de la metodología propuesta en su adquisición. Los resultados indican un dominio de mayor a menor grado en la emisión de hipótesis, diseño de la experimentación, representación cualitativa, identificación de variables y reformulación del problema abierto, así como la influencia positiva de la MRPI en estas dimensiones competenciales sobre la planificación de investigaciones.

  5. Conceptual design of a fluidized bed nuclear reactor: Statics, dynamics and safety-related aspects

    OpenAIRE

    Agung, A.

    2007-01-01

    In this thesis a conceptual design of an innovative high temperature reactor based on the fluidization principle (FLUBER) is proposed. The reactor should satisfy the following requirements: (a) modular and low power, (b)) large shutdown margin, (c) able to produce power when the bed of particles expands and stop as soon as the coolant flow is lost, (d) stable from the reactivity point of view, (e) resistant to inherent fluctuations in the fluidization regime, and (f) able to remove post-shutd...

  6. Adaptation of the continuous cold trap system of fluidized-bed to the fluoride volatility process

    International Nuclear Information System (INIS)

    1976-02-01

    A continuous cold trap system consisting of fluidized condenser and stripper has been evaluated with a view to adapt it to the Fluoride Volatility Process in establishing the continuous purification process without radiation decomposition of PuF 6 . Its feasibility is shown by the test with UF 6 -air. Necessary conditions for the cold trap, and performance of the two inch-dia. fluidized bed cold trap system are presented, and also a model of mist formation in the condenser. (auth.)

  7. An Overview of Atmospheric Fluidized Bed Combustion Systems as Applied to Army Scale Central Heat Plants

    Science.gov (United States)

    1992-11-01

    or burned in a separate fluidizcd bed combustor called a carbon burnup cell. Fuel and Sorbent Feed. To achieve high combustion efficier.cy and maximum...AFBC tecnnology is relatively new, calculating the boiler efficiency of fluidized bed boilers is not as well defined as it is for conventional boilers...paragraphs will highlight some options to improve the combustion efficiency. A carbon burnup cell (CBC) uses a separate fluidized bed operated at a much

  8. A Comparison of Granules Produced by High-Shear and Fluidized-Bed Granulation Methods

    OpenAIRE

    Morin, Garett; Briens, Lauren

    2014-01-01

    Placebo granules were manufactured by both wet high-shear and fluidized-bed techniques. The granules were compared based on size, shape, surface morphology, and a variety of different flowability measurements. This comparison showed that granule formation and growth were different, with induction growth for high-shear granulation and steady growth for fluidized-bed granulation. Final granules from high-shear granulation were more spherical and dense compared with the irregular granules from f...

  9. Dehydration Behaviour of Borax Pentahydrate to Anhydrous Borax by Multi-Stage Heating in a Fluidized

    OpenAIRE

    ŞAHİN, Ömer

    2002-01-01

    In order to optimize the anhydrous borax process in a fluidized bed calcinator, it is absolutely necessary to study the dehydration behaviour of borax pentahydrate. It was found that the basic feature of the dehydration of borax pentahydrate to anhydrous borax is concerned with the conditions employed. The bulk density and sodium borate content of the end product were determined to be a function of number of stages of temperature of the dehydration period in the fluidized bed. It...

  10. Fluidized beds with interal screens. II. Study in a cylindrical reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jodra, L.G.; Aragon, J.M.; Corella, J.

    1979-10-01

    A fluidized bed reactor with several horizontal tube screens was studied. The number of tubes in a row, the number of rows, and the height to the bottom of the screen were varied. The conversion increase for the chemical reaction of butanol and ammonia was used as a criterion to develop several correlations between screen efficiency and the above variables. The application of the results for the design of fluidized beds with internal screens is also given.

  11. OPTIMIZATION OF DESIGN PARAMETERS OF A STIRLING GENERATOR FOR USE WITH A FLUIDIZED BED COMBUSTOR

    OpenAIRE

    Lombardi, Simone; Bizon, Katarzyna; Marra, Francesco; Continillo, Gaetano

    2012-01-01

    This work investigates the possibility to place the head of a Stirling engine, more specifically the elements of the hot side heat exchanger, in direct contact with the sand of a Fluidized Bed Combustor. This choice is primarily suggested by the heat exchange coefficients between the multiphase fluidized bed medium and the surface of the heat exchanger, much larger than those attained when the heat exchanger is located in the stream of hot flue gases. Moreover, the mechanical action exerted b...

  12. Review of the phenomenon of fluidization and its numerical modelling techniques

    Directory of Open Access Journals (Sweden)

    H Khawaja

    2016-10-01

    Full Text Available The paper introduces the phenomenon of fluidization as a process. Fluidization occurs when a fluid (liquid or gas is pushed upwards through a bed of granular material. This may make the granular material to behave like a liquid and, for example, keep a level meniscus on a tilted container, or make a lighter object float on top and a heavier object sink to the bottom. The behavior of the granular material, when fluidized, depends on the superficial gas velocity, particle size, particle density, and fluid properties resulting in various regimes of fluidization. These regimes are discussed in detail in the paper. This paper also discusses the application of fluidized beds from its early usage in the Winkler coal gasifier to more recent applications for manufacturing of carbon nano-tubes. In addition, Geldart grouping based on the range of particle sizes is discussed. The minimum fluidization condition is defined and it is demonstrated that it may be registered slightly different when particles are being fluidized or de-fluidized. The paper presents discussion on three numerical modelling techniques: the two fluid model, unresolved fluid-particle model and resolved fluid particle model. The two fluid model is often referred to Eulerian-Eulerian method of solution and assumes particles as well as fluid as continuum. The unresolved and resolved fluid-particle models are based on Eulerian-Lagrangian method of solution. The key difference between them is the whether to use a drag correlation or solve the boundary layer around the particles. The paper ends with the discussion on the applicability of these models.

  13. Sludge combustion in fluidized bed reactors at laboratory scale

    International Nuclear Information System (INIS)

    Chirone, R.; Cammarota, A.

    2001-01-01

    The combustion of a dried sewage sludge in laboratory scale fluidized bed has been studied in Naples by the Istituto di ricerche sulla combustione (Irc) in the framework of a National project named Thermal Process with Energy Recovery to be used in laboratory and pre-pilot scale apparatus. The attention has been focused on emissions of unreacted carbon as elutriated fines, on the emissions of pollutant gases and on the assessment of the inventory of fly- and bottom ashes. The combustion behaviour of sewage sludge has been compared with those of a market available Tyre Derived Fuel (TDF) and a biomass from Mediterranean area (Robinia Pseudoacacia) and with that of a South African bituminous coal. Stationary combustion tests were carried out at 850 0 C by feeding particles in the size range 0-1 mm into a bed of silica sand without any sorbent addition. The fluidized bed combustor has been operated, at a superficial gas velocity of 0.4 m/s and different excesses of air ranging between 14 and 98%. Relatively high combustion efficiency, larger than 98.9% has been obtained in experiments carried out with sewage sludge and excess of air larger than 20%. These values, are comparable with those obtained in previously experimental activity carried out under similar operative conditions with a South Africa Bituminous coal (97-98%). It is larger than those obtained by using a Tyre Derived Fuel (89-90%) and the Robinia Pseudoacacia Biomass (93-93%). The relative importance of carbon fines elutriation, CO emissions and volatile bypassing the bed in determining the loss of combustion efficiency has been evaluated for the different fuels tested [it

  14. Staged fluidized-bed coal combustor for boiler retrofit

    International Nuclear Information System (INIS)

    Rehmat, A.; Dorfman, L.; Shibayama, G.; Waibel, R.

    1991-01-01

    The Advanced Staged Fluidized-Bed Coal Combustion System (ASC) is a novel clean coal technology for either coal-fired repowering of existing boilers or for incremental power generation using combined-cycle gas turbines. This new technology combines staged combustion for gaseous emission control, in-situ sulfur capture, and an ash agglomeration/vitrification process for the agglomeration/vitrification of ash and spent sorbent, thus rendering solid waste environmentally benign. The market for ASC is expected to be for clean coal-fired repowering of generating units up to 250 MW, especially for units where space is limited. The expected tightening of the environmental requirements on leachable solids residue by-products could considerably increase the marketability for ASC. ASC consists of modular low-pressure vessels in which coal is partially combusted and gasified using stacked fluidized-bed processes to produce low-to-medium-Btu, high-temperature gas. This relatively clean fuel gas is used to repower/refuel existing pulverized-coal, natural gas, or oil-fired boilers using bottom firing and reburning techniques. The benefits of ASC coal-fired repowering include the ability to repower boilers without obtaining additional space while meeting the more stringent environmental requirements of the future. Low NO x , SO x , and particulate levels are expected while a nonleachable solid residue with trace metal encapsulation is produced. ASC also minimizes boiler modification and life-extension expenditures. Repowered efficiencies can be restored to the initial operating plant efficiency, and the existing boiler capacity can be increased by 10%. Preliminary cost estimates indicate that ASC will have up to a $250/kW capital cost advantage over existing coal-fired repowering options. 4 figs., 4 tabs

  15. Environmental remediation with products of fluidized bed combustion

    International Nuclear Information System (INIS)

    Kim, A.G.

    1999-01-01

    Commercialization of fluidized bed combustion (FBC) technology could be enhanced by increased utilization of FBC products (ash). In the US, coal combustion products (CCP) are not hazardous under RCRA and are regulated as residual waste by the states. The composition of CCP from fluidized beds is primarily determined by the inorganic constituents in coal, the sorbent reaction products and the unreacted sorbent. The combustion system and the inclusion of other fuels may also affect the chemical composition, physical properties and leaching behavior. The alkalinity of the FBC material, residual lime and pozzolanic properties are desirable characteristics for use in soil stabilization and mine reclamation. At reclaimed surface coal mines, placement of CCP is intended to reduce the amount of acid mine drainage (AMD) produced at such sites. Neutralization, inhibition of acid forming bacteria, encapsulation of the pyrite or water diversion are believed to be the mechanisms facilitated by the alkaline material. Comparison of water quality, before and after injection of a grout composed of FBC ash and water indicated small increases in pH and decreases in acidity at discharge points. The concentrations of calcium and magnesium in water samples generally increased compared to background levels. The average concentration of trace elements (arsenic, cobalt, copper, nickel and zinc) was slightly elevated in the injection areas, but in down dip and discharge water samples were comparable to background levels. Over a four year period, the average acidity in the injected area decreased by approximately 30%, a value similar to another site where a mixture of class F fly ash and cement was injected. Although coal mine remediation is a beneficial environmental use of FBC products, its effectiveness may be related to the amount of FBCB used and the method of emplacement

  16. Calidad de vida: panorámica de investigaciones clínicas

    Directory of Open Access Journals (Sweden)

    Geraldine V. Padilla

    2005-01-01

    Full Text Available Este informe proporciona una panorámica de investigaciones clínicas pertenecientes a los estudios de la calidad de vida relacionada con la salud (CDVRS incluyendo cuestiones sobre el significado de la calidad de vida en la atención sanitaria, campos y definiciones conceptuales, teorías, definiciones operacionales, la relevancia clínica de resultados estadísticos significativos, y la relación entre investigación clínica, práctica clínica, valoraciones de CDVRS y resultados de CDVRS. Se revisan campos no directamente pertenecientes a la CDVRS y definiciones generales así como los campos y definiciones de la CDVRS. Las teorías y modelos presentados distinguen entre predictores y resultados de calidad de vida. Se describen unas pocas medidas de calidad de vida útiles y bien conocidas, así como útiles depósitos de cuestionarios en páginas web. El concepto de diferencia mínima clínicamente importante proporciona una estrategia para determinar la significación clínica de la significación estadística y más allá de ella. Finalmente se ofrece un modelo basado en la relación cuidador-paciente para explicar la influencia de la investigación clínica en la conducta clínica y los resultados de CDVRS.

  17. CALIDAD DE VIDA: PANORÁMICA DE INVESTIGACIONES CLÍNICAS

    Directory of Open Access Journals (Sweden)

    Geraldine Padilla

    2005-06-01

    Full Text Available Este informe proporciona una panorámica de investigaciones clínicas pertenecientes a los estudios de la calidad de vida relacionada con la salud (CDVRS incluyendo cuestiones sobre el significado de la calidad de vida en la atención sanitaria, campos y definiciones conceptuales, teorías, definiciones operacionales, la relevancia clínica de resultados estadísticos significativos, y la relación entre investigación clínica, práctica clínica, valoraciones de CDVRS y resultados de CDVRS. Se revisan campos no directamente pertenecientes a la CDVRS y definiciones generales así como los campos y definiciones de la CDVRS. Las teorías y modelos presentados distinguen entre predictores y resultados de calidad de vida. Se describen unas pocas medidas de calidad de vida útiles y bien conocidas, así como útiles depósitos de cuestionarios en páginas web. El concepto de diferencia mínima clínicamente importante proporciona una estrategia para determinar la significación clínica de la significación estadística y más allá de ella. Finalmente se ofrece un modelo basado en la relación cuidador-paciente para explicar la influencia de la investigación clínica en la conducta clínica y los resultados de CDVRS.

  18. Temperature and pressure distributions in a 400 kW{sub t} fluidized bed straw gasifier

    Energy Technology Data Exchange (ETDEWEB)

    Erguedenler, A.; Ghaly, A.E.; Hamdullahpur, F. [Technical Univ. of Nova Scotia, Halifax (Canada)

    1993-12-31

    The temperature and pressure distribution characteristics of a 400 kW (thermal) dual-distributor type fluidized bed straw gasifier were investigated. The effects of the bed height, equivalence ratio (actual air-fuel ratio:stoichiometric air-fuel ratio) and fluidization velocity on the temperature and pressure variations in the gasifier were studied. Generally, the bed temperature reached the steady state condition within 15--20 minutes. The average temperature of the dense bed ranged from 649{degrees}C to 875{degrees}C depending on the levels of operating parameters used. The bed temperature increased linearly with increases in the equivalence ratio, higher bed temperatures were observed with lower bed height and no clear trend for the bed temperature with respect to variations in fluidization velocity was observed. The bed height, equivalence ratio and fluidization velocity affected the pressure drop in the fluidized bed gasifier. Increasing the fluidization velocity and/or decreasing the equivalence ratio resulted in higher pressure drops in the dense bed and the freeboard regions whereas increasing the bed height increased the pressure drop only in the dense bed.

  19. Fluidized bed coupled rotary reactor for nanoparticles coating via atomic layer deposition.

    Science.gov (United States)

    Duan, Chen-Long; Liu, Xiao; Shan, Bin; Chen, Rong

    2015-07-01

    A fluidized bed coupled rotary reactor has been designed for coating on nanoparticles (NPs) via atomic layer deposition. It consists of five major parts: reaction chamber, dosing and fluidizing section, pumping section, rotary manipulator components, as well as a double-layer cartridge for the storage of particles. In the deposition procedure, continuous fluidization of particles enlarges and homogenizes the void fraction in the particle bed, while rotation enhances the gas-solid interactions to stabilize fluidization. The particle cartridge presented here enables both the fluidization and rotation acting on the particle bed, demonstrated by the analysis of pressure drop. Moreover, enlarged interstitials and intense gas-solid contact under sufficient fluidizing velocity and proper rotation speed facilitate the precursor delivery throughout the particle bed and consequently provide a fast coating process. The cartridge can ensure precursors flowing through the particle bed exclusively to achieve high utilization without static exposure operation. By optimizing superficial gas velocities and rotation speeds, minimum pulse time for complete coating has been shortened in experiment, and in situ mass spectrometry showed the precursor usage can reach 90%. Inductively coupled plasma-optical emission spectroscopy results suggested a saturated growth of nanoscale Al2O3 films on spherical SiO2 NPs. Finally, the uniformity and composition of the shells were characterized by high angle annular dark field-transmission electron microscopy and energy dispersive X-ray spectroscopy.

  20. From continuum analytical description to discrete numerical modelling of localized fluidization in granular media

    Directory of Open Access Journals (Sweden)

    Puig i Montellà Eduard

    2017-01-01

    Full Text Available We present analytical and numerical results on localized fluidization within a granular layer subjected to a local injection of fluid. As the injection rate increases the three different regimes previously reported in the literature are recovered: homogeneous expansion of the bed, fluidized cavity in which fluidization starts developing above the injection area, and finally the chimney of fluidized grains when the fluidization zone reaches the free surface. The analytical approach is at the continuum scale, based on Darcy’s law and Therzaghi’s effective stress principle. It provides a good description of the phenomenon as long as the porosity of the granular assembly remains relatively homogeneous. The numerical approach is at the particle scale based on the coupled DEM-PFV method. It tackles the more heterogeneous situations which occur at larger injection rates. A direct link is evidenced between the occurrence of the different regimes of fluidization and the injection aperture. Finally, the merging of chimneys in case of two injection points is investigated.

  1. An experimental study of fluidization behavior using flow visualization and image processing

    International Nuclear Information System (INIS)

    Laan, Flavio T. van der; Sefidvash, Farhang; Cornelius, Vanderli

    2000-01-01

    A program of experimental study of fluidization of heavy spherical pellets with water using image processing technique has been started in the Nuclear Engineering Department of the Federal University of Rio Grande do Sul. Fluidization for application in nuclear reactors requires very detailed knowledge of its behavior as the reactivity is closely dependent on the porosity of the fluidized bed. A small modular nuclear reactor concept with suspended core is under study. A modified version of the reactor involves the choice of is to make conical the shape of the reactor core to produce a non-fluctuating bed and consequently guarantee the dynamic stability of the reactor. A 5 mm diameter steel ball are fluidized with water in a conical Plexiglass tube. A pump circulate the water in a loop feeding the room temperature water from the tank into the fluidization system and returning it back to the tank. A controllable valve controls the flow velocity. A high velocity digital CCD camera captures the images of the pellets moving in the fluidized tube. At different flow velocities, the individual pellets can be tracked by processing the sequential frames. A DVT digital tape record stores the images and by acquisition through interface board into a microcomputer. A special program process the data later on. Different algorithm of image treatment determines the velocity fields of the pellets. The behavior of the pellets under different flow velocity and porosity are carefully studied. (author)

  2. Lignite air-steam gasification in the fluidized bed of iron-containing slag catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, B.N.; Shchipko, M.L.; Golovin, Yu. [Inst. of Chemistry of Natural Organic Materials, Academgorodok, Krasnoyarsk (Russian Federation)

    1995-12-01

    The influence of fluidized bed of iron-containing slag particles on air-steam gasification of powdered Kansk-Achinsk lignite in entrained flow was studied in pilot installation with productivity about 60 kg per hour. Slag of Martin process and boiler slag were used as catalytic active materials until their complete mechanical attrition. Two following methods of catalytic gasification of lignite were compared: the partial gasification in stationary fluidized bed of slag particles with degree of fuel conversion 40-70% and complete gasification in circulating bed of slag particles. In the first case only the most reactive part of fuel is gasified with the simultaneously formation of porous carbon residue with good sorption ability. It was found the catalytic fluidized bed improves heat transfer from combustion to reduction zone of gas-generator and increases the rate of fuel conversion at the temperature range 900-1000{degrees}C. At these temperatures the degree of conversion is depended considerably on the duration time of fuel particles in the catalytic fluidized bed. The influence of catalytic fluidized bed height and velocity of reaction mixture on the temperature profiles in the gas-generator was studied. The optimal relationship was found between the fluidized bed height and velocity of flow which makes possible to produce the gas with higher calorific value at maximum degree of fuel conversion.

  3. Instability and the formation of bubbles and the plugs in fluidized beds

    Directory of Open Access Journals (Sweden)

    Piotr Schulz

    2004-01-01

    Full Text Available This is an review paper, particulary concentrate on results not many researches by reason that are explain in the text. We consider stability of disperse, two-phase flow (gas-solid particles or liquid-solid particles linear and non-linear. In particular we discuss the result of Anderson, Sundareson and Jackson (1995 [Anderson K., Sundareson S., Jackson R.: Instabilities and the formation of bubbles in fluidized beds. J. Fluid Mech. 303 (1995, 327-366] that for vertical dispersion flow one- and two-dimensional, they attack problem growing disturbances directly by numerical integration of equations of motion from given initial conditions (using computer Cray C-90. In principle, this would allow authors to explore all aspects of dynamical behaviour of fluidized beds. It is interesting mechanism of periodic plug describing by Anderson et al. and attest by other researchers. Second part of paper is more general, dedicate the problem of linear stability of uniformly fluidized state ("fluidized bed". We make the most important stages of calculations (after to Jackson (2000 [Jackson R.: The Dynamics of Fluidized Particles. Cambridge University Press 2000] and demonstrate that the majority (but not all of fluidized beds with parameters having technical importance is unstable, or stable in narrow interval of wave numbers \\(k\\.

  4. Effect of compaction history on the fluidization behavior of fine cohesive powders

    Science.gov (United States)

    Valverde, Jose Manuel; Castellanos, Antonio

    2006-05-01

    Fine particles agglomerate in the fluidized state due to the strength of interparticle attractive forces as compared to particle weight. Interparticle adhesion can be largely increased by consolidation stresses applied during powder handling. As a consequence, fragments of the consolidated powder may persist when the powder is fluidized, which gives rise to large agglomerates of strongly adhered particles in fluidization. This history-dependent effect can be minimized by coating the particles with surface additives such as silica nanoparticles. In this paper, we investigate the effect of high consolidation stresses σc previously applied to samples of silica-coated fine particles on their fluidization behavior. Our experimental measurements show that, even though homogeneous fluidization is still observed, the average agglomerate size and fractal dimension of the agglomerates increase as σc is increased. Bed expansion in the fluidized state is hindered by previously applied high consolidations, which we attribute to an increase of the largest stable size of mesoscopic fluid pockets. As a consequence, we observe that the initiation of macroscopic bubbling is delayed up to larger values of the fluid velocity.

  5. Weather impact on the electric energy consumption of domestic users; Impacto del clima en el consumo de energia electrica en los usuarios domesticos

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Niembro, Gaudencio; Fiscal Escalante, Raul [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    It is said that when an energy saving and efficient use of energy program is implemented it must be a business for three: the user, the society and the electric utility. In respect to the user, his decision making is quite simple: is it cheaper or more expensive for me?. Unfortunately in many cases we want a very short return time or the money needed for the initial investment is not available. For instance, and incandescent bulb is several times less expensive than a compact fluorescent lamp, but if we make the calculation on the life-time and on the power consumption reduction of the compact fluorescent lamp, we can conclude that this one is more economic. The benefit for the society can be seen under many different aspects, being the most important the natural resources conservation and the environment. From the stand point of the utility the heavier possible factors are the postponement of the investments and the system reliability. When some of the programs of the Demand Side Management (DSM) are applied, the utilities support or promote non financially profitable but improve their image before the user, on creating a consciousness in the saving and in the efficient use of energy: a short term investment is made and a long term revenue is obtained. For this reason for an optimum selection and implementation the saving and the efficient use of electric energy measures a detailed knowledge of the consumption way is required. In this paper the importance of monitoring the way the different type of users employ the energy in order to make up decisions on DSM programs in many different scenarios: cities, type of users, income level, etc. is shown. [Espanol] Se dice que cuando se implementa un programa de ahorro y uso eficiente de la energia electrica, debe ser negocio para tres: el usuario, la sociedad y la empresa electrica. En lo que respecta al usuario, su toma de decision es muy simple: me resulta mas barato o mas caro. Desafortunadamente en muchos de los casos

  6. Demonstration of a Full-Scale Fluidized Bed Bioreactor for the Treatment of Perchlorate at Low Concentrations in Groundwater

    Science.gov (United States)

    2009-01-01

    Fluidized Bed Reactor Iron Granulated Activated Carbon Gallons per minute Health & Safety Plan Hydraulic Residence Time Investigation-Derived Waste...FINAL REPORT Demonstration of a Full-Scale Fluidized Bed Bioreactor for the Treatment of Perchlorate at Low Concentrations in Groundwater...area code) 20-01-2009 Final Report March 2006-March 2008; January 2009 DEMONSTRATION OF A FULL-SCALE FLUIDIZED BED BIOREACTOR FOR THE TREATMENT OF

  7. The Biogas from bio-energy electrical power plant of Nuevo Leon; Central electrica de biogas de bioenergia de Nuevo Leon

    Energy Technology Data Exchange (ETDEWEB)

    Arvizu F, Jose L [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Saldana M, Jaime L [Sistemas de Energia Internacional S.A. de C.V. (Mexico)

    2005-07-01

    The biogas from bio-energy electrical power plant of Nuevo Leon represents, in all the national territory, the first experience on the advantage of biogas emitted by the sanitary landfills for the generation of electrical energy. Therefore, one of the specific objectives of this paper is the one of diffusion and reproduction of the same one in other cities of Mexico and Latin America. The project is framed within the world-wide policies on the control of emissions for the reduction of the greenhouse effect gases (GEG) and its impact in the global climatic change. The gas emitted by the trash sanitary landfills, commonly known as biogas, is a gas mixture derived from the decomposition of the organic matter of the municipal trash by microorganisms in anaerobic conditions. Biogas generated in the sanitary landfills has a methane content of 55% and a 35% of carbon dioxide. The balance 10% is made up of water steam, hydrogen, nitrogen, oxygen, hydrogen sulfur and other gases in minimum amounts. [Spanish] La Central Electrica de Biogas de Bioenergia de Nuevo Leon representa, en todo el territorio nacional, la primera experiencia sobre el aprovechamiento del biogas emitido por los rellenos sanitarios para la generacion de energia electrica. Por esta razon, uno de los objetivos especificos de este trabajo es la de difusion y reproduccion del mismo en otras ciudades de Mexico y Latinoamerica. El proyecto esta enmarcado dentro de las politicas mundiales sobre el control de emisiones para la reduccion de los gases de efecto invernadero (GEI) y su impacto en el cambio climatico global. El gas emitido por la basura dispuesta en los rellenos sanitarios, comunmente conocido como biogas, es una mezcla de gases derivado de la descompensacion de la materia organica de la basura municipal por microorganismos en condiciones anaerobias. El biogas generado en los rellenos sanitarios tiene un contenido de metano del 55% y un 35% de bioxido de carbono. El 10% restante se compone de vapor

  8. Development and implementation of a pilot network for continuous monitoring of electric energy; Desarrollo e implantacion de una red piloto de monitoreo continuo de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Cifuentes, A.; Cortes Eslava, A. [Facultad de Ingenieria, UNAM, Mexico, D. F. (Mexico)

    1997-12-31

    The ``Programa Universitario de Energia (PUE)`` (University Energy Program) of the Universidad Nacional Autonoma de Mexico (UNAM) through the project ``Ecologic Control of The University Campus`` has the objective of instrumenting policies for the rational use of the electric energy in the UNAM installations. The PUE has performed a series of activities aimed at the establishment of an integral program for the electric energy management in the UNAM. This program has to consider the measures for energy saving (MES) of general kind and to promote a series of specific measures to be adequated and implemented for each one of the departments. The success in establishing a series of MES compels to quantify its effects, to register and to analyze them to be in position of enhancing them, since it must be kept in mind that something that can not be measured can not be improved. For this purpose the PUE is developing a continuous monitoring pilot network of electric energy with local and remote access and an automated metering system. Two monitoring schemes are experimented, one commercial metering equipment and another one with own metering technology. In this paper the characteristics of the proposed monitoring schemes are described. [Espanol] El Programa Universitario de Energia (PUE) de la Universidad Nacional Autonoma de Mexico (UNAM), a traves del proyecto {sup C}ontrol Ecologico del Campus Universitario{sup ,} tiene como objetivo instrumentar politicas de uso racional de la energia en las instalaciones universitarias. El PUE ha realizado una serie de actividades encaminadas a establecer un programa integral de administracion de la energia electrica en la UNAM. El programa mencionado debe considerar medidas de ahorro de energia (MAE) de tipo general y promover una serie de medidas particulares, para ser adecuadas e implantadas por cada una de las dependencias. El exito en el establecimiento de una serie de MAE, obliga a cuantificar sus efectos, registrarse y

  9. Heat transfer characteristics in a pulsated fluidized bed in relation to bubble characteristics; Parusu ryudoso no dennetsu tokusei to kiho tokusei tono sokan

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, A.; Hasatani, M. [Nagoya Univ., Nagoya (Japan). Dept. of Energy Engineering and Science; Deguchi, S. [Nagoya Univ., Nagoya (Japan). Center for Integrated Research inn Science and Engineering; Matsuda, H. [Nagoya Univ., Nagoya (Japan). Research Center for Advanced Waste and Emission Management; Mujumdar, A.S. [McGill Univ., Quebec (Canada). Dept. of Chemical Engineering

    2000-11-10

    A pulsated fluidized bed is operated with two sequential duration designated as the on-period with injecting fluidization air, and the off-period without injecting fluidization air. The heat transfer coefficient between a vertically immersed heater and bed in a pulsated fluidized bed is measured under various pulse cycles and fluidized particles. The obtained results are compared with those in a normal fluidized bed with continuous fluidization air injection. The relation between heat transfer coefficient and bubble characteristics, evaluated by using a digital video camera, was investigated. For certain fluidized particles and operated pulse cycles, fluidization of particles and increment of heat transfer coefficient can be obtained under lower mean air velocity based on a pulse cycle duration than minimum fluidization air velocity of the normal fluidized bed. Under the pulse cycles where a static ed is formed in off-period duration, the improved heat transfer rate in contrast with the normal fluidized bed can be measured. This because of the large bubbles formation. As the heat transfer in the pulsated fluidized bed is obstructed with increasing time to keep a static bed due to the excess of-period duration it is indicated that there is an optimum off-period duration based on the heat transfer rate. (author)

  10. Sorption-enhanced steam methane reforming in fluidized bed reactors

    Energy Technology Data Exchange (ETDEWEB)

    Johnsen, Kim

    2006-10-15

    Hydrogen is considered to be an important potential energy carrier; however, its advantages are unlikely to be realized unless efficient means can be found to produce it without generation of CO{sub 2}. Sorption-enhanced steam methane reforming (SE-SMR) represent a novel, energy-efficient hydrogen production route with in situ CO{sub 2} capture, shifting the reforming and water gas shift reactions beyond their conventional thermodynamic limits. The use of fluidized bed reactors for SE-SMR has been investigated. Arctic dolomite, a calcium-based natural sorbent, was chosen as the primary CO{sub 2}-acceptor in this study due to high absorption capacity, relatively high reaction rate and low cost. An experimental investigation was conducted in a bubbling fluidized bed reactor of diameter 0.1 m, which was operated cyclically and batch wise, alternating between reforming/carbonation conditions and higher-temperature calcination conditions. Hydrogen concentrations of >98 mole% on a dry basis were reached at 600 C and 1 atm, for superficial gas velocities in the range of {approx}0.03-0.1 m/s. Multiple reforming-regeneration cycles showed that the hydrogen concentration remained at {approx}98 mole% after four cycles. The total production time was reduced with an increasing number of cycles due to loss of CO{sub 2}-uptake capacity of the dolomite, but the reaction rates of steam reforming and carbonation seemed to be unaffected for the conditions investigated. A modified shrinking core model was applied for deriving carbonation kinetics of Arctic dolomite, using experimental data from a novel thermo gravimetric reactor. An apparent activation energy of 32.6 kj/mole was found from parameter fitting, which is in good agreement with previous reported results. The derived rate expression was able to predict experimental conversion up to {approx}30% very well, whereas the prediction of higher conversion levels was poorer. However, the residence time of sorbent in a continuous

  11. Evolution of the Radio-sterilized Tissues Bank of the Instituto Nacional de Investigaciones Nucleares

    International Nuclear Information System (INIS)

    Martinez P, M. E.; Reyes F, M. L.; Luna Z, D.

    2013-10-01

    The Radio-sterilized Tissues Bank (RTB) of the Instituto Nacional de Investigaciones Nucleares (ININ) was established in 1997, as national project supported by the IAEA, who provided equipment, training and expert missions. In July of 1999, the Secretaria de Salud (Mexico) granted the sanitary license to the RTB. The first radio-sterilized tissue was the amnion. Later on, the process of frozen and lyophilized pig skin was development. Both tissue types are used as biological dressings in patient with burns, ulcers or on injuries difficult to heal, the amnion is also used for the damage treatment in the ocular surface. In 2003, the ININ improved the facilities of the RTB and in August of that same year the certification of the Quality Administration System was obtained under the standard ISO 9001:2000, at the present time ISO 9001:2008. The support of the IAEA granted to Mexico was of 1997-2004 and 2009-2012, by means of regional and inter regional projects where was obtained equipment and training mainly, for personal of the ININ and other institutions. With the last project supported by the IAEA, two very important documents were generated for the tissues bank of Argentina, Brazil, Colombia, Costa Rica, Cuba, Ecuador, El Salvador, Mexico, Peru, Uruguay and Venezuela, strengthening the interaction among these countries. To offer more radio-sterilized tissues to the medical community, in June of 2007 the RTB signed and agreement with the Secretaria de Salud of the Mexico State by means of the Centro Estatal de Transplantes del Estado de Mexico, for the process of muscle-skeletal tissue, skin and amnion. At present, besides amnion and pig skin, in the RTB there is in existence powdered and chips bone; concluding the validation stage the human skin process is. As a social function of the ININ, the RTB has contributed to the health improvement of patients of more than 50 hospital institutions, mainly those that assist to patient of low resources in different cities of

  12. Estimadores de consistencia interna en las investigaciones en salud: el uso del coeficiente alfa

    Directory of Open Access Journals (Sweden)

    Franciele Cascaes da Silva

    Full Text Available La producción académica ha aumentado en el área de la salud, exigiendo cada vez más calidad en las publicaciones de gran impacto. Una de las formas de considerar la calidad es por medio de procedimientos que aumentan la consistencia del análisis de los datos, como la confiabilidad, que dependiendo del tipo de datos, puede ser evaluada por diferentes coeficientes, en especial el coeficiente alfa. Basados en lo anterior, la presente revisión reúne sistemáticamente artículos científicos producidos en los últimos cinco años, que de manera metodológica hicieron uso psicométrico del coeficiente α como un estimador de consistencia interna y de confiabilidad en procesos de construcción, adaptación y validación de instrumentos. La identificación de los estudios fue realizada sistemáticamente en las bases de datos Biomed Central Journals, Google Scholar, Web of Science, Wiley Online Library, Medline via Pubmed, Scielo, Scopus, Journals@Ovid, BMJ y Springer por medio del Portal de Periódicos CAPES, utilizando criterios de inclusión y exclusión. El análisis de los datos fue realizado por medio de triangulación, análisis de contenido y análisis descriptivo. Se obtuvo que la mayoría de los estudios fueron realizados principalmente en Irán (f=3, España (f=2 y Brasil (f=2, estos estudios tuvieron como objetivo testar las propiedades psicométricas de instrumentos, siendo que ocho estudios utilizaron el coeficiente α para evaluar la confiabilidad y nueve para evaluar la consistencia interna. Todos los estudios fueron clasificados como investigaciones metodológicas al analizar sus objetivos. Adicionalmente, cuatro estudios también fueron clasificados como correlacionales y uno como descriptivo-correlacional. Se puede concluir que a pesar de que el coeficiente α es ampliamente utilizado como uno de los principales parámetros para la evaluación de consistencia interna de instrumentos de medición del tipo cuestionario en el

  13. Electrochemical generation of energy: from the portable electronic devices to industrial plants; Generacion electroquimica de energia electrica: de los dispositivos electronicos portatiles a las plantas industriales

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Varela, Javier [Centro de Investigacion y de Estudios Avanzados (CINVESTAV), Unidad Saltillo (Mexico)

    2006-10-15

    This article proposes the electrical energy generation via electrochemistry as substitute of petroleum and discusses on the development of low and high temperature fuel cells fed by diverse types of fuels: electrolyte fuel cells of polymeric membrane, PEM cells H{sub 2}/O{sub 2}, cell of direct alcohol consumption, PEM cells and bio-fuel cells, SOFC cells and bio-fuel cells. It presents its constitution, operation principles, and use plausibility, present situation in the market, advantages and disadvantages, as well as already made cell insertion projects. [Spanish] Este trabajo propone la generacion de energia electrica via electroquimica como sustituto del petroleo y discurre sobre el desarrollo de celdas de combustible de baja y alta temperatura alimentadas por diversos tipos de combustibles: celdas de combustible de electrolito de membrana polimerica, celda PEM H{sub 2}/O{sub 2}, celda de consumo directo de alcohol, celdas PEM y biocombustibles, celdas de combustible de oxido solido y biocombustibles. Expone su constitucion, principios de operacion, plausibilidad de uso, situacion actual en el mercado, ventajas y desventajas, asi como proyectos de insercion de celdas ya realizados.

  14. The satisfaction of developing a project of electrical energy saving; La satisfaccion de desarrollar un proyecto de ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Arreola Suarez, Alejandro [Hotel Club Marival, Nuevo Vallarta, Nayarit (Mexico)

    2002-09-01

    The projects for the energy saving in hotels represent a great opportunity to reduce the operation costs in the demand and consumption of electrical energy, since the existing facilities can take advantage of new technologies in illumination, air conditioning, refrigeration and heating. By their constitution, the hotels work the year around uninterruptedly and must provide all type of services to the guests and working personnel, which originates that they consume great amounts of energy in air conditioning, lightning, laundry, etc., since the prestige of the installation depends on it. [Spanish] Los proyectos para el ahorro de energia en hoteles representan una gran oportunidad para reducir costos de operacion en la demanda y consumo de energia electrica, ya que las instalaciones existentes pueden aprovechar nuevas tecnologias en iluminacion, aire acondicionado, refrigeracion y calefaccion. Por su constitucion, los hoteles trabajan ininterrumpidamente todo el ano y deben proporcionar toda clase de servicios a los huespedes y personal que labora, lo cual origina que consuman grandes cantidades de energia en aire acondicionado, iluminacion, lavanderia, etc., pues de ello depende el prestigio de la instalacion.

  15. Energy losses produced by differential currents in the metallic ducts of electric installations; Perdidas de energia producidas por corrientes diferenciales en la tuberia metalica de instalaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Campero L, Eduardo; Bratu S, Neagu; Marquez M, Luis; Caballero R, Rafael [Universidad Autonoma Metropolitana Unidad Azcapotzalco, Mexico, D. F. (Mexico)

    1994-12-31

    In this article it is explained what is known as differential currents and the conditions in which they appear in the electrical installations. A short outline is made on the magnetic induction phenomenon that appears in metallic conduits, due to the circulation of differential currents along the inside of the tube and that in turn produces energy losses in the form of heat, that is dissipated in the tube surrounding environment. The results of the measurements performed in the laboratory are shown in order to quantify the energy losses in the metallic conduit. It was found that for certain conditions these losses are significant. [Espanol] En este articulo se explica lo que se entiende por corrientes diferenciales y se describen las condiciones en las que estas aparecen en las instalaciones electricas. Se plantea brevemente el fenomeno de induccion magnetica que aparece en las tuberias metalicas, debido a la circulacion de corrientes diferenciales por el interior del tubo y que a su vez produce perdidas de energia en forma de calor, que se disipa en el ambiente que rodea al tubo. Se muestran los resultados de las mediciones que se llevaron a cabo en laboratorio para poder cuantificar las perdidas en tuberia metalica conduit. Se encontro que para ciertas condiciones estas perdidas son significativas.

  16. The electric power generation in Mexico and its environmental impacts: Past, present and future; La generacion electrica en Mexico y sus impactos ambientales: Pasado, presente y futuro

    Energy Technology Data Exchange (ETDEWEB)

    Quintanilla Martinez, Juan [Programa Universitario de Energia (PUE), Universidad Nacional Autonoma de Mexico (UNAM), Mexico, D. F. (Mexico)

    1997-12-31

    The purpose of this paper is to analyze the historical evolution, past and present of the installed capacity and of the electric power generation, as well as the fuel consumption and the associated green-house gases emission. Also, under the technique of economic scenarios and future towns (in short and mediate terms) the potential needs of installed capacity, generation, mix and fuel consumption and associated green gases emissions is analyzed. Later on a comment is made on the energy implications of the substitution of fuels policies and the environmental Standards. Finally, a series of comments is established on the possible technological directions for the sector, from the stand point of generation efficiency and its effects in the reduction of emissions [Espanol] El proposito del presente trabajo es analizar la evolucion historica, pasada y presente, de la capacidad instalada y de la generacion electrica, asi como el consumo de combustibles y las emisiones de gases de invernadero asociadas. Tambien se analiza bajo la tecnica de escenarios economicos y poblaciones a futuro (en el corto y mediano plazo) las posibles necesidades de capacidad instalada, generacion, mezcla y consumo de combustibles y emisiones de gases de invernadero asociadas. Posteriormente se comenta sobre las implicaciones energeticas de las politicas de sustitucion de combustibles y estandares ambientales. Por ultimo se establecen una serie de comentarios sobre las posibles direcciones tecnologicas para el sector, desde el punto de vista de la eficiencia de generacion y sus efectos en la reduccion de las emisiones

  17. Educational software tool for protection system engineers: distance relay; Herramienta educativa para la formacion de ingenieros en protecciones electricas: relevador de distancia

    Energy Technology Data Exchange (ETDEWEB)

    Trujillo-Guajardo, L.A.; Conde-Enriquez, A. [Universidad Autonoma de Nuevo Leon, Nuevo Leon (Mexico)]. E-mail: luistrujillo84@gmail.com; con_de@yahoo.com

    2012-04-15

    In this article, a graphical software tool is presented; this tool is based on the education of protection system engineers. The theoretical fundaments used for the design of operation characteristics of distance relays and their algorithms are presented. The software allows the evaluation and analysis of real time events or simulated ones of every stage of design of the distance relay. Some example cases are presented to illustrate the activities that could be done with the graphical software tool developed. [Spanish] En este articulo se presenta una herramienta computacional grafica para apoyar la formacion de ingenieros en protecciones electricas. Los fundamentos teoricos para el diseno de caracteristicas de operacion de relevadores de distancia, asi como las rutinas de programacion de un relevador de distancia son presentados. La herramienta desarrollada permite la evaluacion de las etapas de diseno de relevadores y el analisis de la operacion ante eventos reales o simulados. Se presentan algunos casos de ejemplo para ilustrar las actividades didacticas que son posibles de realizar con la herramienta presentada.

  18. Experimental investigation of thermal conductivity coefficient and heat exchange between fluidized bed and inclined exchange surface

    Directory of Open Access Journals (Sweden)

    B. Stojanovic

    2009-06-01

    Full Text Available The paper presents experimental research of thermal conductivity coefficients of the siliceous sand bed fluidized by air and an experimental investigation of the particle size influence on the heat transfer coefficient between fluidized bed and inclined exchange surfaces. The measurements were performed for the specific fluidization velocity and sand particle diameters d p=0.3, 0.5, 0.9 mm. The industrial use of fluidized beds has been increasing rapidly in the past 20 years owing to their useful characteristics. One of the outstanding characteristics of a fluidized bed is that it tends to maintain a uniform temperature even with nonuniform heat release. On the basis of experimental research, the influence of the process's operational parameters on the obtained values of the bed's thermal conductivity has been analyzed. The results show direct dependence of thermal conductivity on the intensity of mixing, the degree of fluidization, and the size of particles. In the axial direction, the coefficients that have been treated have values a whole order higher than in the radial direction. Comparison of experimental research results with experimental results of other authors shows good agreement and the same tendency of thermal conductivity change. It is well known in the literature that the value of the heat transfer coefficient is the highest in the horizontal and the smallest in the vertical position of the heat exchange surface. Variation of heat transfer, depending on inclination angle is not examined in detail. The difference between the values of the relative heat transfer coefficient between vertical and horizontal heater position for all particle sizes reduces by approximately 15% with the increase of fluidization rate.

  19. La competencia sobre planificación de investigaciones en 4º de ESO: un estudio de caso

    OpenAIRE

    Iñigo RODRÍGUEZ ARTECHE; Mª Mercedes MARTÍNEZ AZNAR; Mª Aránzazu GARITAGOITIA CID

    2016-01-01

    En los últimos años, las metodologías de tipo “Inquiry-Based Science Education” (IBSE) se vienen recomendando desde las instancias europeas para mejorar los niveles de competencia y las actitudes hacia la ciencia de los estudiantes. Así, el presente estudio pretende comprobar la eficacia de una metodología IBSE, la Metodología de Resolución de Problemas como Investigación (MRPI), para la enseñanza-aprendizaje de la competencia sobre planificación de investigaciones en 4º de ESO. Para ello, a ...

  20. La planificación de investigaciones y su evaluación en 4º de ESO

    OpenAIRE

    Martínez Aznar, Mª Mercedes; Rodríguez Arteche, Iñigo; Garitagoitia Cid, Mª Aránzazu

    2013-01-01

    En este trabajo se comprueba la eficacia de la resolución de situaciones problemáticas abiertas mediante la Metodología de Resolución de Problemas como Investigación (MRPI), de características Inquiry-Based Science Education, para el desarrollo de la competencia científica, en concreto de sus aspectos ligados a la planificación de investigaciones. A partir de las producciones de un grupo de escolares de 4º de ESO se analiza el progreso en los aprendizajes que permiten evaluar el grado de comp...

  1. Overview of some biomedical research projects in tropical medicine conducted at the Instituto Venezolano de Investigaciones Cientificas

    Directory of Open Access Journals (Sweden)

    Romano Egidio

    2000-01-01

    Full Text Available The Instituto Venezolano de Investigaciones Cientificas (IVIC is a government-funded multidisciplinary academic institution dedicated to research, development and technology in many areas of knowledge. Biomedical projects and publications comprise about 40% of the total at IVIC. In this article, we present an overview of some selected research and development projects conducted at IVIC which we believe contain new and important aspects related to malaria, ancylostomiasis, dengue fever, leishmaniasis and tuberculosis. Other projects considered of interest in the general area of tropical medicine are briefly described. This article was prepared as a small contribution to honor and commemorate the centenary of the Instituto Oswaldo Cruz.

  2. Investigaciones sobre la catepsina del jugo gástrico. Su papel en la digestión estomacal

    OpenAIRE

    Segovia García, Francisco

    1988-01-01

    Resume este trabajo la labor de varios años. Iniciado en el Laboratorio de Investigaciones Bioquímicas de la Cátedra del Profesor M. Díaz Rubio (Laboratorio que tuve el honor de dirigir), enfocó como primer objetivo, el conocimiento de la enzima para ulteriores trabajos de índole clínica. Estos primeros ensayos se hicieron sobre jugo gástrico humano, y no obstante haber llegado a algunas conclusiones, plasmadas en sendas comunicaciones...

  3. Impacto social de las investigaciones en el municipio de Rodas. Estudio de caso en la carrera de Procesos Agroindustriales

    Directory of Open Access Journals (Sweden)

    Gladys Elena Capote León

    2016-01-01

    Full Text Available RESUMEN El trabajo aborda el impacto social de las investigaciones científicas, realizadas por la carrera de Ingeniería en Procesos Agroindustriales, en el municipio de Rodas durante el período 2012-2013. Los resultados fundamentales que se obtienen se relacionan con un procedimiento conformado por tres etapas: diagnóstico, medición de impactos y evaluación de resultados. La primera etapa incluye una caracterización del municipio y clasifica las investigaciones por temáticas y organismos del territorio, de acuerdos al conjunto de instrumentos propuestos para ello. En la segunda, a través de variables (articulación de las investigaciones con la realidad, conocimiento e innovación de la puesta en práctica de los resultados e impacto de la gestión investigativa en el municipio y de un conjunto de indicadores para cada una de ellas, se mide el impacto social que las investigaciones realizadas tienen en el desarrollo del territorio. En la tercera etapa se realiza una evaluación de los resultados obtenidos de cada variable e indicadores. El procedimiento, validado por consenso de expertos, garantiza una valoración con respecto a la pertinencia, viabilidad y aplicabilidad de las mismas, lo que permite a los gobiernos locales trazar políticas científicas y de gestión en correspondencia con las necesidades y prioridades identificadas en el entorno local Social impact of research in the municipality of Rodas. Case study in the Agroindustrial Process career. ABSTRACT The paper addresses the social impact of scientific research, conducted by the Engineering Agroindustrial Processes in the municipality of Rhodes during the period 2012-2013. The main results obtained relate to a process consisting of three stages: diagnosis, impact measurement and evaluation of results. The first stage includes a description of the municipality and classified by subject and research bodies of the territory, of agreements to set it proposed instruments. In

  4. Investigation of Gas Solid Fluidized Bed Dynamics with Non-Spherical Particles

    Energy Technology Data Exchange (ETDEWEB)

    Choudhuri, Ahsan [Univ. of Texas, El Paso, TX (United States). Dept. of Mechanical Engineering

    2013-06-30

    One of the largest challenges for 21st century is to fulfill global energy demand while also reducing detrimental impacts of energy generation and use on the environment. Gasification is a promising technology to meet the requirement of reduced emissions without compromising performance. Coal gasification is not an incinerating process; rather than burning coal completely a partial combustion takes place in the presence of steam and limited amounts of oxygen. In this controlled environment, a chemical reaction takes place to produce a mixture of clean synthetic gas. Gas-solid fluidized bed is one such type of gasification technology. During gasification, the mixing behavior of solid (coal) and gas and their flow patterns can be very complicated to understand. Many attempts have taken place in laboratory scale to understand bed hydrodynamics with spherical particles though in actual applications with coal, the particles are non-spherical. This issue drove the documented attempt presented here to investigate fluidized bed behavior using different ranges of non-spherical particles, as well as spherical. For this investigation, various parameters are controlled that included particle size, bed height, bed diameter and particle shape. Particles ranged from 355 µm to 1180 µm, bed diameter varied from 2 cm to 7 cm, two fluidized beds with diameters of 3.4 cm and 12.4 cm, for the spherical and non-spherical shaped particles that were taken into consideration. Pressure drop was measured with increasing superficial gas velocity. The velocity required in order to start to fluidize the particle is called the minimum fluidization velocity, which is one of the most important parameters to design and optimize within a gas-solid fluidized bed. This minimum fluidization velocity was monitored during investigation while observing variables factors and their effect on this velocity. From our investigation, it has been found that minimum fluidization velocity is independent of bed

  5. Advanced Magnetic Materials Methods and Numerical Models for Fluidization in Microgravity and Hypogravity

    Science.gov (United States)

    Atwater, James; Wheeler, Richard, Jr.; Akse, James; Jovanovic, Goran; Reed, Brian

    2013-01-01

    To support long-duration manned missions in space such as a permanent lunar base, Mars transit, or Mars Surface Mission, improved methods for the treatment of solid wastes, particularly methods that recover valuable resources, are needed. The ability to operate under microgravity and hypogravity conditions is essential to meet this objective. The utilization of magnetic forces to manipulate granular magnetic media has provided the means to treat solid wastes under variable gravity conditions by filtration using a consolidated magnetic media bed followed by thermal processing of the solid wastes in a fluidized bed reactor. Non-uniform magnetic fields will produce a magnetic field gradient in a bed of magnetically susceptible media toward the distributor plate of a fluidized bed reactor. A correctly oriented magnetic field gradient will generate a downward direct force on magnetic media that can substitute for gravitational force in microgravity, or which may augment low levels of gravity, such as on the Moon or Mars. This approach is termed Gradient Magnetically Assisted Fluidization (G-MAFB), in which the magnitude of the force on the fluidized media depends upon the intensity of the magnetic field (H), the intensity of the field gradient (dH/dz), and the magnetic susceptibility of the media. Fluidized beds based on the G-MAFB process can operate in any gravitational environment by tuning the magnetic field appropriately. Magnetic materials and methods have been developed that enable G-MAFB operation under variable gravity conditions.

  6. [Thermal energy utilization analysis and energy conservation measures of fluidized bed dryer].

    Science.gov (United States)

    Xing, Liming; Zhao, Zhengsheng

    2012-07-01

    To propose measures for enhancing thermal energy utilization by analyzing drying process and operation principle of fluidized bed dryers,in order to guide optimization and upgrade of fluidized bed drying equipment. Through a systematic analysis on drying process and operation principle of fluidized beds,the energy conservation law was adopted to calculate thermal energy of dryers. The thermal energy of fluidized bed dryers is mainly used to make up for thermal consumption of water evaporation (Qw), hot air from outlet equipment (Qe), thermal consumption for heating and drying wet materials (Qm) and heat dissipation to surroundings through hot air pipelines and cyclone separators. Effective measures and major approaches to enhance thermal energy utilization of fluidized bed dryers were to reduce exhaust gas out by the loss of heat Qe, recycle dryer export air quantity of heat, preserve heat for dry towers, hot air pipes and cyclone separators, dehumidify clean air in inlets and reasonably control drying time and air temperature. Such technical parameters such air supply rate, air inlet temperature and humidity, material temperature and outlet temperature and humidity are set and controlled to effectively save energy during the drying process and reduce the production cost.

  7. Flow characteristics in a large jetting fluidized bed with two nozzles

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Q.; Liu, Z.; Zhang, J.

    2000-03-01

    Jetting fluidized beds are widely used in a number of industrial processes because of various advantages, such as high rates of heat and mass transfer and chemical reaction. These processes include catalytic and flame processes, combustion and gasification of coal, treatment of wastes, cleaning of dusty gases, coating, and granulation. The penetration depth for millet (1.64 mm) as fluidization particles (Geldart group D) was determined in a large jetting fluidized bed of 0.5 m inner diameter and 8 m height and with two nozzles is precorded by a video camera and analyzed frame by frame. Based on experimental data, an empirical correlation for the penetration depth is proposed. Experimental results indicate that the penetration depth increases with an increase in the jetting velocity. Under the same jet gas velocity, the penetration depth decreases as the nozzle distance decreases. Meanwhile, a simple correlation for jet coalescence height is found. A radial voidage profile in the jetting fluidized bed is investigated using a PC-4 fiber optic concentration probe, the effects of jet gas velocity, and the distance between two nozzles on the radial voidage distribution, and a radial profile with unequal jet gas velocity in a jetting fluidized bed is studied.

  8. Biological reduction of nitrates in wastewaters from nuclear processing using a fluidized-bed bioreactor

    International Nuclear Information System (INIS)

    Pitt, W.W.; Hancher, C.W.; Patton, B.D.

    1981-01-01

    There are a number of nitrate-containing wastewater sources, as concentrated as 30 wt.% NO 3 - and as large as 2000 m 3 /day, in the nuclear fuel cycle. The biological reduction of nitrate in wastewater to gaseous nitrogen, accompanied by the oxidation of a nutrient carbon source to gaseous carbon dioxide, is an ecologically sound and cost-effective method of treating wastewaters containing nitrates. These nitrate-containing wastewater sources can be successfully biologically denitrified to meet discharge standards in the range of 10 to 20 gN(NO 3 - )/m 3 by the use of a fluidized-bed bioreactor. The denitrification bacteria are a mixed culture derived from garden soil; the major strain is Pseudomonas. In the fluidized-bed bioreactor the bacteria are allowed to attach to 0.25- to 0.50-mm-diam coal fluidization particles, which are then fluidized by the upward flow of influent wastewater. Maintaining the bacteria-to-coal weight ratio at approximately 1:10 results in a bioreactor bacteria loading of greater than 20,000 g/m 3 . This paper describes the results of a biodenitrification R and D program based on the use of fluidized bioreactors capable of operating at nitrate levels up to 7000 g/m 3 and achieving denitrification rates as high as 80 g N(NO 3 - ) per day per liter of empty bioreactor volume. 4 figures, 7 tables

  9. Simulation of energetic- and exergetic performance of microwave-assisted fluidized bed drying of soybeans

    International Nuclear Information System (INIS)

    Ranjbaran, M.; Zare, D.

    2013-01-01

    The performance of microwave-assisted fluidized bed drying of soybeans was simulated (using a previously validated mathematical model) and analyzed based on the first- and second law of thermodynamics. The energy and exergy analysis were carried out for several drying conditions. The effects of inlet air temperature, microwave power density, bed thickness and inlet air velocity on the efficiencies and inefficiencies of drying process have been simulated and discussed. Generally, application of microwave energy during fluidized bed drying enhanced the exergy efficiency of drying process. However, the results showed that it was more efficient not to apply microwave energy at the first stage of fluidized bed drying process. The application of higher levels of drying air temperature led in higher exergy efficiencies. The values of mean relative deviations for the predictions of efficiencies and inefficiencies of drying process were less than 14%, compared with those calculated using experimental data. - Highlights: • Introducing a mathematical model to predict the efficiency of microwave-assisted fluidized bed dryers. • Energy and exergy analysis in microwave-assisted fluidized bed drying of grains. • Providing practical recommendations for efficient use of microwave power during drying

  10. Fast Pyrolysis of Agricultural Wastes in a Fluidized Bed Reactor

    Science.gov (United States)

    Wang, X. H.; Chen, H. P.; Yang, H. P.; Dai, X. M.; Zhang, S. H.

    Solid biomass can be converted into liquid fuel through fast pyrolysis, which is convenient to be stored and transported with potential to be used as a fossil oil substitute. In China, agricultural wastes are the main biomass materials, whose pyrolysis process has not been researched adequately compared to forestry wastes. As the representative agricultural wastes in China, peanut shell and maize stalk were involved in this paper and pine wood sawdust was considered for comparing the different pyrolysis behaviors of agricultural wastes and forestry wastes. Fast pyrolysis experiments were carried out in a bench-scale fluidized-bed reactor. The bio-oil yieldsof peanut shell and maize stalk were obviously lower than that ofpine sawdust. Compared with pine sawdust, the char yields of peanut shell and maize stalk were higher but the heating value of uncondensable gaswas lower. This means that the bio-oil cost will be higher for agricultural wastes if taking the conventional pyrolysis technique. And the characteristic and component analysis resultsof bio-oil revealed that the quality of bio-oil from agricultural wastes, especially maize stalk, was worse than that from pine wood. Therefore, it is important to take some methods to improve the quality of bio-oilfrom agricultural wastes, which should promote the exploitation of Chinese biomass resources through fast pyrolysis in afluidized bed reactor.

  11. Research into Biomass and Waste Gasification in Atmospheric Fluidized Bed

    Energy Technology Data Exchange (ETDEWEB)

    Skala, Zdenek; Ochrana, Ladislav; Lisy, Martin; Balas, Marek; Kohout, Premysl; Skoblja, Sergej

    2007-07-01

    Considerable attention is paid in the Czech Republic to renewable energy sources. The largest potential, out of them all, have biomass and waste. The aim therefore is to use them in CHP in smaller units (up to 5MWel). These are the subject of the research summarized in our article. The paper presents results of experimental research into gasification in a 100 kW AFB gasifier situated in Energy Institute, Faculty of Mechanical Engineering, Brno University of Technology, and fitted with gas cleaning equipment. Within the research, study was carried out into gas cleaning taking primary measures in the fluidized bed and using hot filter, metal-based catalytic filter, and wet scrubber. Descriptions and diagrams are given of the gasifier and new ways of cleaning. Results include: Impact of various fuels (farming and forest wastes and fast-growing woods and culm plants) on fuel gas quality. Individual kinds of biomass have very different thermal and physical properties; Efficiency of a variety of cleaning methods on content of dust and tars and comparison of these methods; and, Impact of gasifier process parameters on resultant gas quality. (auth)

  12. Operation of a fluidized-bed bioreactor for denitrification

    International Nuclear Information System (INIS)

    Hancher, C.W.; Taylor, P.A.; Napier, J.M.

    1978-01-01

    Two denitrification fluidized-bed bioreactors of the same length (i.e., 5 m) but with different inside diameters (i.e., 5 and 10 cm) have been operated on feed ranging in nitrate concentration from 200 to 2000 g/m 3 ; thus far, good agreement has been obtained. Two 10-cm-ID bioreactors operating in series have also been tested; the results are in accordance with predicted results based on the performance of a 5-cm-ID bioreactor. The overall denitrification rate in the dual 10-cm-ID bioreactor system was found to be 23 kg N(NO 3 - )/day-m 3 using feed with a nitrate concentration of 1800 g/m 3 . Data obtained in operating-temperature tests indicate that the maximum denitrification rate is achieved between 22 and 30 0 C. These data will form the basis of the design of our mobile pilot plant which consists of dual 20-cm-ID by 7.3-m-long bioreactors

  13. Attempts on cardoon gasification in two different circulating fluidized beds

    Directory of Open Access Journals (Sweden)

    Chr. Christodoulou

    2014-11-01

    Full Text Available Few tests have been carried out in order to evaluate the use of cardoon in gasification and combustion applications most of the researchers dealt with agglomeration problems. The aim of this work is to deal with the agglomeration problem and to present a solution for the utilization of this biofuel at a near industrial application scale. For this reason, two experiments were conducted, one in TU Delft and one in Centre for Research and Technology Hellas (CERTH, using fuel cardoon and 50% w/w cardoon blended with 50% w/w giant reed respectively. Both experimental campaigns were carried out in similar atmospheric circulating fluidized bed gasifiers. Apart from the feedstock, the other differences were the gasification medium and the bed material used in each trial. The oxidizing agent at TUD׳s run was O2/steam, whereas CERTH׳s tests used air. When experiments with the cardoon 50% w/w–giant reed 50% w/w blend were performed no agglomeration problems were presented. Consequently, gasification could be achieved in higher temperature than that of pure cardoon which led to the reduction of tar concentration.

  14. Sulfide oxidation in fluidized bed bioreactor using nylon support material.

    Science.gov (United States)

    Midha, Varsha; Jha, M K; Dey, Apurba

    2012-01-01

    A continuous fluidized bed bioreactor (FBBR) with nylon support particles was used to treat synthetic sulfide wastewater at different hydraulic retention time of 25, 50 and 75 min and upflow velocity of 14, 17 and 20 m/hr. The effects of upflow velocity, hydraulic retention time and reactor operation time on sulfide oxidation rate were studied using statistical model. Mixed culture obtained from the activated sludge, taken from tannery effluent treatment plant, was used as a source for microorganisms. The diameter and density of the nylon particles were 2-3 mm and 1140 kg/m3, respectively. Experiments were carried out in the reactor at a temperature of (30 +/- 2) degrees C, at a fixed bed height of 16 cm after the formation of biofilm on the surface of support particles. Biofilm thickness reached (42 +/- 3) microm after 15 days from reactor start-up. The sulfide oxidation, sulfate and sulfur formation is examined at all hydraulic retention times and upflow velocities. The results indicated that almost 90%-92% sulfide oxidation was achieved at all hydraulic retention times. Statistical model could explain 94% of the variability and analysis of variance showed that upflow velocity and hydraulic retention time slightly affected the sulfide oxidation rate. The highest sulfide oxidation of 92% with 70% sulfur was obtained at hydraulic retention time of 75 min and upflow velocity of 14 m/hr.

  15. Heavy metal characterization of circulating fluidized bed derived biomass ash.

    Science.gov (United States)

    Li, Lianming; Yu, Chunjiang; Bai, Jisong; Wang, Qinhui; Luo, Zhongyang

    2012-09-30

    Although the direct combustion of biomass for energy that applies circulating fluidized bed (CFB) technology is steadily expanding worldwide, only few studies have conducted an environmental assessment of biomass ash thus far. Therefore, this study aims to integrate information on the environmental effects of biomass ash. We investigated the concentration of heavy metal in biomass ash samples (bottom ash, cyclone ash, and filter ash) derived from a CFB boiler that combusted agricultural and forest residues at a biomass power plant (2×12 MW) in China. Ash samples were gathered for the digestion and leaching test. The heavy metal content in the solution and the leachate was studied via an inductively coupled plasma-mass spectrometer and a Malvern Mastersizer 2000 mercury analyzer. Measurements for the chemical composition, particle size distribution, and the surface morphology were carried out. Most of the metals in cyclone ash particles were enriched, whereas Ti and Hg were enriched in filter ash. Residence time contributed most to heavy metal enrichment. Under HJ/T 300 conditions, the heavy metals showed serious leaching characteristics. Under EN 12457-2 conditions, leaching behavior was hardly detected. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Modern fluidized bed combustion in Ostrava-Karvina cogeneration plants

    Energy Technology Data Exchange (ETDEWEB)

    Mazac, V. [Energoprojekt Praha, Ostrava (Czechoslovakia); Novacek, A. [Moravskoslezske teplamy, Ostrava (Czechoslovakia); Volny, J. [Templamy Karvina (Czechoslovakia)

    1995-12-01

    The contemporary situation of our environment claims the sensitive approach to solving effective conversion of energy. Limited supplies of noble fuels and their prices evoke the need to use new combustion technologies of accessible fuels in given region without negative ecological influences. Energoproject participates in the preparation of the two projects in Ostrava-Karvin{acute a} black coal field in Czech Republic. The most effective usage of fuel energy is the combined of electricity and heat. If this physical principle is supported by a pressurized fluidized bed combustion (PFBC) one obtains a high electricity/heat ratio integrated steam-gas cycle on the basis of solid fuel. Cogeneration plant Toebovice is the dominant source (600 MW{sub th}) of Ostrava district heating system (1100 MW{sub th}). The high utilization of the installed output and utilization of the clean, compact and efficient of the PFBC technology is the principal but not the single reason for the selection of the Toebovice power plant as the first cogeneration plant for installation of the PFBC in Czech Republic. The boiler will burn black coal from the neighboring coal basin.

  17. Combustion test of refuse derived fuel in fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Piao, Guilin; Aono, Shegeru; Yamazaki, Ryohei; Fujima, Yukihisa; Mori, Shigekatsu [Nagoya University, Aichi (Japan); Kondo, Motohiro; Yamaguchi, Masataka [Toyota Motor Corp., Aichi (Japan)

    1999-08-01

    Power generation from Refuse Derived Fuel (RFD) is a promising utilization technology for municipal municipal solid waste. To explain the combustion behaviors of RDF was fed continuously in to a 0.3 x 0.3 m x 2.73 m in height bubbling-type fluidized bed combustor and CO, NO{sub x}, SO{sub x} and HCl concentrations in the flue gas from the combustor were detected by a continuos measurement system. It is found that CO concentration in the flue gas is greatly increased by increasing the RFD feed rate, and CO concentration in the flue gas is greatly decreased by increasing the air ratio because the volatile matters rate is extremely great in combustion of RFD. It is also significantly affected by the secondary air injection and the air distribution ratio from the distributor. HCl concentration in the flue gas is effectively controlled by the calcium compound contained in RDF.HCl concentration is maintained to be less than 60 ppm when the bed temperature is 800 degree C, and the HCl removal ratio by the calcium component is higher than 70% even though under the higher bed temperature than 900 degree C. NO{sub x} concentration was among 50-150 ppm and SO{sub x} concentration is less than 0.5 ppm. (author)

  18. Development of a membrane-assisted fluidized bed reactor - 2 - Experimental demonstration and modeling for the partial oxidation of methanol

    NARCIS (Netherlands)

    Deshmukh, S.A.R.K.; Laverman, J.A.; van Sint Annaland, M.; Kuipers, J.A.M.

    2005-01-01

    A small laboratory-scale membrane-assisted fluidized bed reactor (MAFBR) was constructed in order to experimentally demonstrate the reactor concept for the partial oxidation of methanol to formaldehyde. Methanol conversion and product selectivities were measured at various overall fluidization

  19. Comparison of fibre optical measurements and discrete element simulations for the study of granulation in a spout fluidized bed

    NARCIS (Netherlands)

    Link, J.M.; Godlieb, W.; Tripp, P.; Deen, N.G.; Heinrich, S.; Kuipers, J.A.M.; Schönherr, M.; Peglow, M.

    2009-01-01

    Spout fluidized beds are frequently used for the production of granules or particles through granulation. The products find application in a large variety of applications, for example detergents, fertilizers, pharmaceuticals and food. Spout fluidized beds have a number of advantageous properties,

  20. Comparison of fibre optical measurements and discrete element simulations for the study of granulation in a spout fluidized bed

    NARCIS (Netherlands)

    Link, J.M.; Godlieb, W.; Tripp, P.; Deen, N.G.; Heinrich, S.; Peglow, M.; Kumar, J.; Kuipers, J.A.M.; Schönherr, M.; Mörl, L.

    2007-01-01

    Spout fluidized beds are frequently used for the production of granules or particles through granulation. The products find application in a large variety of applications, for example detergents, fertilizers, pharmaceuticals and food. Spout fluidized beds have a number of advantageous properties,

  1. Comparison of Fibre Optical Measurements and Discrete Element Simulations for the Study of Granulation in a Spout Fluidized Bed

    NARCIS (Netherlands)

    Link, J.M.; Godlieb, W.; Tripp, P.; Deen, N.G.; Heinrich, S.; Kuipers, J.A.M.; Schönherr, M.; Peglow, M.

    2007-01-01

    Spout fluidized beds are frequently used for the production of granules or particles through granulation. The products find application in a large variety of applications, for example detergents, fertilizers, pharmaceuticals and food. Spout fluidized beds have a number of advantageous properties,

  2. Use of Pressure Fluctuations to Determine Online the Regime of Gas-Solids Suspensions from Incipient Fluidization to Transport

    Czech Academy of Sciences Publication Activity Database

    Hartman, Miloslav; Trnka, Otakar; Svoboda, Karel

    2009-01-01

    Roč. 48, č. 14 (2009), s. 6830-6835 ISSN 0888-5885 R&D Projects: GA AV ČR IAA400720701 Institutional research plan: CEZ:AV0Z40720504 Keywords : fluidized beds * fluidization regimes * pressure fluctuations Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.758, year: 2009

  3. Role of microbial accumulation in biological sulphate reduction using lactate as electron donor in an inversed fluidized bed bioreactor

    NARCIS (Netherlands)

    Cassidy, J.; Frunzo, L.; Lubberding, H.J.; Villa-Gomez, D.K.; Esposito, G.; Keesman, K.J.; Lens, P.N.L.

    2017-01-01

    This study evaluated the impact of substrate accumulation (sulphate and polyhydroxybutyrate (PHB)) on bioprocess control of a sulfate reducing inversed fluidized bed bioreactor. To investigate the impact of substrate accumulation, step feed changes were induced to an inversed fluidized bed

  4. Energy saving by means of air conditioning equipment replacement and the household application of thermal insulation; Ahorro de energia electrica por reemplazo de equipos de aire acondicionado y aplicacion de aislamiento termico en viviendas

    Energy Technology Data Exchange (ETDEWEB)

    Peralta Solorio, Jose Luis [Fideicomiso para el Ahorro de la Energia (Mexico)

    2005-07-15

    An extension study of the Financing Program for Energy Saving looked for the evaluation of the electric energy saving potential obtained by the replacement of air conditioning equipment and the application of thermal insulation in 30 houses of two Mexican cities with warmth climate. In a joint effort with Comision Federal de Electricidad the consumption files of the users were analyzed and field measurements of electric demand and of refrigeration were made. As a following step the change of the refrigeration necessities derived from the application of thermal insulation were evaluated as well as the energy efficiency improvement obtained by the substitution of the air conditioning equipment and the favorable results obtained by the implementation of both measures - thermal insulation and change of air conditioning equipment in a joint form. This way, as a conclusion, the optimum sequence of application of these measures is revealed. [Spanish] Un estudio extension del Programa de Financiamiento para el Ahorro de Energia Electrica busco evaluar el potencial de ahorro de energia electrica alcanzado por el reemplazo de equipos de aire acondicionado y la aplicacion de aislamiento termico en 30 viviendas de dos ciudades mexicanas con clima calido. En un esfuerzo conjunto con la Comision Federal de Electricidad se analizaron los historiales de consumo de los usuarios y se efectuaron las mediciones de campo de demanda electrica y de refrigeracion. Como paso siguiente se valoro el cambio en las necesidades de refrigeracion derivado de la aplicacion de aislamiento termico al igual que la mejora en eficiencia energetica obtenida por la sustitucion de aire acondicionado y se identificaron los resultados favorecedores arrojados por la implementacion de ambas medidas -aislamiento termico y cambio de equipo de aire acondicionado- en forma conjunta. De esta manera, como conclusion, se devela la mas optima secuencia de aplicacion de estas medidas.

  5. LA INVESTIGACION COMO CONTENIDO, METODO, ENFOQUE Y CONTEXTO EN LA FORMACIÓN DE LOS PROFESIONALES EN LA UNIVERSIDAD CONTEMPORANEA.

    Directory of Open Access Journals (Sweden)

    Alina Martínez

    2016-04-01

    La universidad, tiene un papel fundamental en el proceso respectivo y potencia las competencias de sus educandos, y entre las funciones principales la creacion de cultura a partir de los procesos de investigacion que en ella se genera y, consecuentemente, participa de manera activa en la solucion de los problemas del entorno, lo que tambien constituye su encargo social; siendo este fundamental en el proceso y la prioridad en la formacion para la investigacion de los estudiantes y al desarrollo de habilidades formativas como parte de sus competencias profesionales, ademas de la autopreparacion y cpacitacion permanente del docente vínculo clave en los procesos de desarrollo. La capacidad laboral mediad a través de las competencias, que el educando recibe en su proceso de formacion, es la búsqueda de los elementos necesarios que constituyen habilidades, destrezas, comportamientos debidamente organizados a fin de lograr metas y objetivos concretos, estos deben ser medidos y cualificados con eficacia, dentro de los niveles de rendimiento exigidos en el trabajo; se logra con la adquisicion y desarrollo de conocimientos, expresados en el desempeño a través de la integracion del saber, el saber hacer y saber ser.

  6. The tissue bank at the Instituto Nacional de Investigaciones Nucleares: ISO 9001:2000 certification of its quality management system.

    Science.gov (United States)

    Martínez-Pardo, María Esther; Mariano-Magaña, David

    2007-01-01

    Tissue banking is a complex operation concerned with the organisation and coordination of all the steps, that is, from donor selection up to storage and distribution of the final products for therapeutic, diagnostic, instruction and research purposes. An appropriate quality framework should be established in order to cover all the specific methodology as well as the general aspects of quality management, such as research and development, design, instruction and training, specific documentation, traceability, corrective action, client satisfaction, and the like. Such a framework can be obtained by developing a quality management system (QMS) in accordance with a suitable international standard: ISO 9001:2000. This paper presents the implementation process of the tissue bank QMS at the Instituto Nacional de Investigaciones Nucleares in Mexico. The objective of the paper is to share the experience gained by the tissue bank personnel [radiosterilised tissue bank (BTR)] at the Instituto Nacional de Investigaciones Nucleares (ININ, National Institute of Nuclear Research), during implementation of the ISO 9001:2000 certification process. At present, the quality management system (QMS) of ININ also complies with the Mexican standard NMX-CC-9001:2000. The scope of this QMS is Research, Development and Processing of Biological Tissues Sterilised by Gamma Radiation, among others.

  7. Study of process parameters for reducing ammonium uranyl carbonate to uranium dioxide in fluidized bed furnace

    International Nuclear Information System (INIS)

    Leitao Junior, C.B.

    1992-01-01

    This work consists of studying the process parameters of AUC (ammonium uranyl carbonate) to U O 2 (uranium dioxide) reduction, with good physical and chemical characteristics, in fluidized bed. Initially, it was performed U O 2 cold fluidization experiments with an acrylic column. Afterward, it was done AUC to U O 2 reduction experiments, in which the process parameters influence in the granulometry, specific surface area, porosity and fluoride amount on the U O 2 powder produced were studied. As a last step, it was done compacting and sintering tests of U O 2 pellets in order to appreciate the U O 2 powder performance, obtained by fluidized bed, in the fuel pellets fabrication. (author)

  8. Bioavailability of sulfadiazine in rabbits using tablets prepared by direct compression and fluidized-bed granulation.

    Science.gov (United States)

    Ritschel, W A; Erni, W

    1977-10-01

    Experimental sulfadiazine tablets prepared by direct compression, using a commercially available direct compression tablet mass, were compared with experimental sulfadiazine tablets prepared by fluidized-bed granulation and commercially available sulfadiazine tablets USP. The values for friability and the time required to release 10 and 50% of the direct compression tablets were between those of the fluidized-bed tablets and the commercial product. With the commercial tablet as a standard, the extent of bioavailability was determined in rabbits; it was slightly higher for both the direct compression and fluidized-bed tablets. A statistically significant difference was found between the direct compression tablets and the standard with respect to the extent of bioavailability and the time of the peak.

  9. ESTABLISHMENT OF AN ENVIRONMENTAL CONTROL TECHNOLOGY LABORATORY WITH A CIRCULATING FLUIDIZED-BED COMBUSTION SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Wei-Ping Pan; Andy Wu; John T. Riley

    2004-10-30

    This report is to present the progress made on the project ''Establishment of an Environmental Control Technology Laboratory (ECTL) with a Circulating Fluidized-Bed Combustion (CFBC) System'' during the period July 1, 2004 through September 30, 2004. The following tasks have been completed. First, renovation of the new Combustion Laboratory and the construction of the Circulating Fluidized-Bed (CFB) Combustor Building have started. Second, the design if the component parts of the CFBC system have been reviewed and finalized so that the drawings may be released to the manufacturers during the next quarter. Third, the experiments for solid waste (chicken litter) incineration have been conducted using a Thermogravimetric Analyzer (TGA). This is in preparation for testing in the simulated fluidized-bed combustor. The experimental results from this study are presented in this report. Finally, the proposed work for the next quarter has been outlined in this report.

  10. Autocorrelation spectra of an air-fluidized granular system measured by NMR

    Science.gov (United States)

    Lasic, S.; Stepisnik, J.; Mohoric, A.; Sersa, I.; Planinsic, G.

    2006-09-01

    A novel insight into the dynamics of a fluidized granular system is given by a nuclear magnetic resonance method that yields the spin-echo attenuation proportional to the spectrum of the grain positional fluctuation. Measurements of the air-fluidized oil-filled spheres and mustard seeds at different degrees of fluidization and grain volume fractions provide the velocity autocorrelation that differs from the commonly anticipated exponential Enskog decay. An empiric formula, which corresponds to the model of grain caging at collisions with adjacent beads, fits well to the experimental data. Its parameters are the characteristic collision time, the free path between collisions and the cage-breaking rate or the diffusion-like constant, which decreases with increasing grain volume fraction. Mean-squared displacements calculated from the correlation spectrum clearly show transitions from ballistic, through sub-diffusion and into diffusion regimes of grain motion.

  11. Heat transfer and flow characteristics around a finned-tube bank heat exchanger in fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Honda, Ryosuke [Department of Mechanical Engineering, Kansai University, 3-3-35 Yamate-cho, Suita, Osaka 564-8680 (Japan); Umekawa, Hisashi [Department of Mechanical Engineering, Kansai University, 3-3-35 Yamate-cho, Suita, Osaka 564-8680 (Japan)], E-mail: umekawa@kansai-uac.jp; Ozawa, Mamoru [Department of Mechanical Engineering, Kansai University, 3-3-35 Yamate-cho, Suita, Osaka 564-8680 (Japan)

    2009-06-21

    Principal heat transfer mechanisms in a fluidized bed have been classified into three categories, i.e. solid convection, gas convection and radiation. Among these mechanisms, the solid convection is a dominant mechanism in the bubbling fluidized bed. This solid convection is substantially caused by the bubble movement, thus the visualization of the void fraction distribution becomes a very useful method to understand the characteristics of the fluidized-bed heat exchanger. In this study, the heat transfer coefficient and the void fraction around the heat transfer tube with annuler fin were measured. For the quantitative measurement of the void fraction, neutron radiography and image processing technique were employed. Owing to the existence of the annuler fin, the restriction of the particle movements was put. This restriction suppressed the disturbance caused by tubes, and the influence of the tube arrangement on the flow and heat transfer characteristics could be clearly expressed.

  12. Development of a pressurized fluidized-bed biomass gsifier to produce substitute fuels

    Science.gov (United States)

    Babu, S. P.; Onischak, M.; Kosowski, G.

    The Institute of Gas technology (IGT) is conducting a program to convert forest and crop residues to substitute fuel in a pressurized fluidized-bed biomass gasifier. The process is designed for operation at pressures up to 2.17 MPa (315 psia) and temperatures up to 1255 K (1800 F). Various goals for synthesis or fuel gas processes are being pursued to develop an efficient process. Some of these goals are to maximize the throughput, the amount, and the quality of the gas, while minimizing both the amount of the feedstock preparation needed and the formation of condensible compounds that require by-product disposal and process wastewater treatment. The process development results obtained from fluidization biomass devolatilization, and char gasification studies were used to design a 30/5-cm (12-inch) ID adiabatic fluidized-bed gasification process development unit (PDU), capable of handling up to 455 kg (1000 lb) of biomass per hour.

  13. Co-combustion of risk husk with coal in a fluidized bed

    International Nuclear Information System (INIS)

    Ghani, A.K.; Alias, A.B.; Savory, R.M.; Cliffe, K.R.

    2006-01-01

    Power generation from biomass is an attractive technology which utilizes agricultural residue waste. In order to explain the behavior of biomass-fired fluidized bed incinerator, biomass sources from agricultural residues (rice husk) was co-fired with coal in a 0.15 m diameter and 2.3 m high fluidized bed combustor. The combustion efficiency and CO emissions were studied and compared with those for pure coal combustion. Biomass waste with up to 70% mass fraction can be co-combusted in a fluidized bed combustor designed for coal combustion with a maximum drop of efficiency of 20% depending upon excess air levels. CO levels fluctuated between 200-700 ppm were observed when coal is added. It is evident from this research that efficient co-firing of rice husk with coal can be achieved with minimum modification of existing coal-fired boilers. (Author)

  14. Capacitor model to interpret the electric behavior of fluidized beds. Influence of apparatus geometry

    Energy Technology Data Exchange (ETDEWEB)

    Rojo, V.; Guardiola, J.; Vian, A.

    1986-01-01

    This work provides a model to know the degree of electrification in fluidized beds on the basis of voltage measurements between an electric probe and a metallic distributor. The model is based on the similarity of behavior between the probe-bed-distributor system and a capacitor. The influence of three variables related to apparatus geometry - height of probe, column diameter and height of bed - has been studied in an air fluidized bed of glass beads. The results show that the degree of bed electrification is not influenced by the column diameter; the effect of bed height depends on the quality of fluidization: with a bubbling bed the degree of electrification increases with bed height whereas the opposite effect is observed with a slugging bed. Additional fixed bed experiments make clear that the rate of charge dissipation grows for increasing values of bed height and column diameter, and for decreasing values of probe height.

  15. Heat transfer and flow characteristics around a finned-tube bank heat exchanger in fluidized bed

    International Nuclear Information System (INIS)

    Honda, Ryosuke; Umekawa, Hisashi; Ozawa, Mamoru

    2009-01-01

    Principal heat transfer mechanisms in a fluidized bed have been classified into three categories, i.e. solid convection, gas convection and radiation. Among these mechanisms, the solid convection is a dominant mechanism in the bubbling fluidized bed. This solid convection is substantially caused by the bubble movement, thus the visualization of the void fraction distribution becomes a very useful method to understand the characteristics of the fluidized-bed heat exchanger. In this study, the heat transfer coefficient and the void fraction around the heat transfer tube with annuler fin were measured. For the quantitative measurement of the void fraction, neutron radiography and image processing technique were employed. Owing to the existence of the annuler fin, the restriction of the particle movements was put. This restriction suppressed the disturbance caused by tubes, and the influence of the tube arrangement on the flow and heat transfer characteristics could be clearly expressed.

  16. Metal wastage design guidelines for bubbling fluidized-bed combustors. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Lyczkowski, R.W.; Podolski, W.F.; Bouillard, J.X.; Folga, S.M. [Argonne National Lab., IL (United States)

    1992-11-01

    These metal wastage design guidelines identify relationships between metal wastage and (1) design parameters (such as tube size, tube spacing and pitch, tube bundle and fluidized-bed height to distributor, and heat exchanger tube material properties) and (2) operating parameters (such as fluidizing velocity, particle size, particle hardness, and angularity). The guidelines are of both a quantitative and qualitative nature. Simplified mechanistic models are described, which account for the essential hydrodynamics and metal wastage processes occurring in bubbling fluidized beds. The empirical correlational approach complements the use of these models in the development of these design guidelines. Data used for model and guideline validation are summarized and referenced. Sample calculations and recommended design procedures are included. The influences of dependent variables on metal wastage, such as solids velocity, bubble size, and in-bed pressure fluctuations, are discussed.

  17. Defluidization in fluidized bed gasifiers using high-alkali content fuels

    DEFF Research Database (Denmark)

    Narayan, Vikas; Jensen, Peter Arendt; Henriksen, Ulrik Birk

    2016-01-01

    samples,agglomeration could be attributed to viscous silicate melts formed from reaction of inorganic alkalineand alkali earth species with silica from the bed particles. A mathematical model that addresses the defluidization behavior of alkali-rich samples was developed based on the experiments performed...... and calcium, which may form viscous melts that adhere on the surface of the colliding bed particles and bind them to form agglomerates. In this paper, studies were made to understand the behavior of inorganic elements (mainly K, Si and Ca) on agglomeration and de-fluidization of alkali rich bed...... in the bench-scale fluidized bed reactor as well as on results from literature. The model was then used topredict the de-fluidization behavior of alkali-rich bed material in a large-scale LTCFB gasifier....

  18. An alternative method for float-sink analysis of fine coal samples using water fluidization

    Energy Technology Data Exchange (ETDEWEB)

    A.M. Callen; S.J. Pratten; B.D. Belcher; N. Lambert; K.P. Galvin [University of Newcastle, Callaghan, NSW (Australia). School of Engineering

    2002-12-01

    The study reported is concerned with the development of a new method, based on water fluidization, for obtaining washability information for -4 +0.045 mm coal samples, with a view to providing a rapid, accurate, and safe alternative to the current laboratory method of float-sink testing. Previously, Galvin and Pratten have reported the technique of utilizing the density segregation effect of a narrow size range of particles in a fluidized bed to determine washability data. Here, the evaluation of the new method by determining the yield-ash data of a number of different Australian coals has demonstrated the robustness and accuracy of the water fluidization method. 7 refs., 9 figs., 1 app.

  19. Time series analysis of pressure fluctuation in gas-solid fluidized beds

    Directory of Open Access Journals (Sweden)

    C. Alberto S. Felipe

    2004-09-01

    Full Text Available The purpose of the present work was to study the differentiation of states of typical fluidization (single bubble, multiple bubble and slugging in a gas-solid fluidized bed, using spectral analysis of pressure fluctuation time series. The effects of the method of measuring (differential and absolute pressure fluctuations and the axial position of the probes in the fluidization column on the identification of each of the regimes studied were evaluated. Fast Fourier Transform (FFT was the mathematic tool used to analysing the data of pressure fluctuations, which expresses the behavior of a time series in the frequency domain. Results indicated that the plenum chamber was a place for reliable measurement and that care should be taken in measurement in the dense phase. The method allowed fluid dynamic regimes to be differentiated by their dominant frequency characteristics.

  20. Fluid dynamic study of a new type of solid-gas contactor: the fluidized/fixed or fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Corella, J.; Bilbao, R.

    1982-10-01

    A fluid dynamic study of a new type of solid-gas contactor has been realized. This contactor consists of a fluidized bed with a considerable enlargement of the cross section of its upper zone. This enlargement of section results in a reduction of the gas velocity in the upper zone, with a subsequent bubbling diminution. Experiments have been performed varying the scale of the contactor, its geometry, the relation between the cross sections of the upper and lower zones of the contactor, the solid height in the upper zone, and the density and size of the solid. The study has been centered on the contactor behavior with variation of the inlet gas velocity, on the bubble size distribution along the contactor, on the determination of the gas pressure drop in the whole contactor and in each zone of the bed, and on the calculation of the gas velocities modifying the state of the contactor (u /SUB r/, u /SUB c/, u /SUB mf/).

  1. The use of reflecting paints on building`s roofs for energy saving; Uso de pinturas reflejantes en los techos de las edificaciones para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Valera Negrete, Jose Adrian [Programa de Ahorro de Energia del Sector Electrico (PAESE), Comision Federal de Electricidad, Mexico, D. F. (Mexico); Sanchez Soto, Ramon [Facultad de Ingenieria, Departamento de Termoenergia de la UNAM, Mexico, D. F. (Mexico)

    1998-12-31

    This paper shows the effects of the use of reflecting paints in different colors on the buildings roofs and the results in energy saving obtained in a field test carried on in Monterrey, Nuevo Leon State of Mexico using aluminum paint. [Espanol] El presente trabajo muestra los efectos del uso de pinturas reflejantes de diferentes colores en los techos de edificaciones, y los resultados de ahorro de energia electrica obtenidos en una prueba de campo efectuada en Monterrey, Nuevo Leon, Mexico, utilizando pintura de aluminio.

  2. The presence of harmonics in electric installations and some of its consequences; La presencia de corrientes armonicas en instalaciones electricas y algunas de sus consecuencias

    Energy Technology Data Exchange (ETDEWEB)

    Bratu Serban, Neagu; Campero Littlewood, Eduardo [Universidad Autonoma Metropolitana Azcapotzalco, Mexico, D. F. (Mexico)

    1996-12-31

    This paper is a short introduction to how the sinusoidal voltage waves are generated. A revision is made on the way of representing a distorted wave and the way of quantifying its harmonics content (harmonics distortion). An overview is made of the non-lineal consuming elements that produce distortion of the current waves. A revision is made on the concept of a power factor in conditions of waves with harmonic distortion. The consequences of feeding with distorted waves the different devices such as motors (particularly for the distortion originated by the rectifiers and the velocity electronic controls), transformers and capacitors. Mention is made of some of the methods for not to produce or for reducing the harmonic effect in the electric networks. The purpose of this article is to review the consequences on energy consumption by the presence of harmonics. [Espanol] En este articulo se hace una breve introduccion de la forma en que se generan las ondas senoidales de voltaje. Se revisa la manera de representar una onda distorsionada y la manera de cuantificar su contenido de armonicas (distorsion armonica). Se repasan los elementos consumidores no lineales que producen la deformacion de las ondas de corriente. Se revisa el concepto de factor de potencia en condiciones de ondas con distorsion armonica. Se analizan las consecuencias de alimentar con ondas distorsionadas a diferentes equipos como motores (particularmente por la distorsion originada por los rectificadores y los controladores de velocidad electronicos), transformadores y capacitores. Se mencionan algunos metodos para no producir, o reducir el efecto armonico en las redes electricas. El proposito de este articulo es revisar las consecuencias sobre el consumo de energia por la presencia de armonicas.

  3. Online monitoring of accessories for underground electrical installations through acoustics emissions; Monitoreo en linea de accesorios de instalaciones electricas subterraneas mediante emisiones acusticas

    Energy Technology Data Exchange (ETDEWEB)

    Casals-Torrens, P. [Universidad Politecnica de Cataluna, Barcelona (Espana)]. E-mail: p.casals@upc.edu; Gonzalez-Parada, A. [Universidad de Guanajuato, Guanajuato (Mexico)]. E-mail: gonzaleza@salamanca.ugto.mx; Bosch-Tous, R. [Universidad Politecnica de Cataluna, Barcelona (Espana)

    2012-04-15

    The acoustic waves caused by Partial Discharges inside the dielectric materials, can be detected by acoustic emission (AE) sensors and analyzed in the time domain. The experimental results presented, show the online detection capability of these sensors in the environment near a cable accessory, such as a splice or terminal. The AE sensors are immune to electromagnetic interference and constitute a detection method non-intrusive and non-destructive, which ensures a galvanic decoupling with respect to electric networks, this technique of partial discharge detection can be applied as a test method for preventive or predictive maintenance (condition-based maintenance) to equipment or facilities of medium and high voltage in service and represents an alternative method to electrical detection systems, conventional or not, that continue to rely on the detection of current pulses. This paper presents characterization tests of the sensors AE through comparative tests of partial discharge on accessories for underground power cables. [Spanish] Las ondas acusticas provocadas por las descargas parciales en el interior de un dielectrico pueden ser detectadas por sensores de Emisiones Acusticas (EA) y analizadas en el dominio del tiempo. Los resultados experimentales que se presentan, evidencian la capacidad de deteccion en linea de estos sensores, en el entorno proximo a un accesorio de cable, empalme o terminal. Los sensores EA son inmunes a las interferencias electromagneticas, son un metodo de deteccion no destructivo y garantizan desacople galvanico respecto a la red electrica; esta tecnica de deteccion de descargas parciales puede ser aplicada como metodo de prueba para mantenimiento preventivo o predictivo (mantenimiento basado en la condicion), en equipos o instalaciones de media y alta tension en servicio, y representa una alternativa a los sistemas electricos de deteccion, convencionales o no, que continuan basandose en la deteccion del impulsos de corriente. En el

  4. Algorithms for the evaluation of the reliability of networks and substations; Algoritmos para evaluar la confiabilidad de redes y subestaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Vega Ortiz, Miguel [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    Two algorithms are presented, one for analyzing the reliability of networks and another one to analyzing the reliability of electrical substations. The algorithms model a network or a substation by means of a graph and determine all the exits, of up to third degree, which isolates the load points. The algorithm that is used for the network analysis, is the one of p-cuts and in the case of the substations it is the one of minimum ways, for later, from these minimum p-cuts and of the minimum ways, obtains the minimum cuts. These minimum cuts are evaluated with the approximate method and give as a result the system reliability and of each one of the components that have been modeled. At the end some examples and results obtained are shown. As case of study, the algorithm is applied to two substations arrangements and to a network of industrial distribution, but it is possible to be applied to transmission and distribution networks. [Spanish] Se presentan dos algoritmos, uno para analizar la confiabilidad de redes y otro para analizar la confiabilidad de subestaciones electricas. Los algoritmos modelan una red o una subestacion por medio de un grafo y determinan todas las salidas, de hasta tercer grado, que aislan los puntos de carga. El algoritmo que se utiliza para el analisis de redes, es el de p-cortes y en el caso de las subestaciones es el de caminos minimos, para despues, a partir de estos p-cortes minimos y de los caminos minimos, obtener los cortes minimos. Estos cortes minimos se evaluan con el metodo aproximado y dan como resultado la confiabilidad del sistema y de cada una de las componentes que se hayan modelado. Al final se muestran algunos ejemplos y resultados obtenidos. Como caso de estudio, el algoritmo se aplica a dos arreglos de subestaciones y a una red de distribucion industrial, pero se puede aplicar a redes de transmision y de distribucion.

  5. CFD-DEM and Experimental Study of Bubbling in a Fluidized Bed

    Directory of Open Access Journals (Sweden)

    Hassan A. Khawaja

    2015-12-01

    Full Text Available In this study, phenomenon of bubbling is investigated using CFD-DEM and experiments. A CFD-DEM simulation is setup to model the fluidized beds of different sizes. Geldart D particles of 1.2 mm diameter and 1000 Kg/m3 density are modelled. Study revealed different types of fluidization regimes as stated in the literature. An experimental setup is built to obtain the results for the comparison. Comparison revealed that results obtained from both methodologies; CFD-DEM and experiments are in reasonable agreement.

  6. Experimental studies on combustion of composite biomass pellets in fluidized bed.

    Science.gov (United States)

    Guo, Feihong; Zhong, Zhaoping

    2017-12-01

    This work presents studies on the combustion of Composite Biomass Pellets (CBP S ) in fluidized bed using bauxite particles as the bed material. Prior to the combustion experiment, cold-flow characterization and thermogravimetric analysis are performed to investigate the effect of air velocity and combustion mechanism of CBP S . The cold-state test shows that CBPs and bauxite particles fluidize well in the fluidized bed. However, because of the presence of large CBPs, optimization of the fluidization velocity is rather challenging. CBPs can gather at the bottom of the fluidized bed at lower gas velocities. On the contrary, when the velocity is too high, they accumulate in the upper section of the fluidized bed. The suitable fluidization velocity for the system in this study was found to be between 1.5-2.0m/s. At the same time, it is found that the critical fluidization velocity and the pressure fluctuation of the two-component system increase with the increase of CBPs mass concentration. The thermogravimetric experiment verifies that the combustion of CBPs is a first-order reaction, and it is divided into three stages: (i) dehydration, (ii) release and combustion of the volatile and (iii) the coke combustion. The combustion of CBPs is mainly based on the stage of volatile combustion, and its activation energy is greater than that of char combustion. During the combustion test, CBP S are burned at a 10kg/h feed rate, while the excess air is varied from 25% to 100%. Temperatures of the bed and flue gas concentrations (O 2 , CO, SO 2 and NO) are recorded. CBPs can be burnt stably, and the temperature of dense phase is maintained at 765-780°C. With the increase of the air velocity, the main combustion region has a tendency to move up. While the combustion is stable, O 2 and CO 2 concentrations are maintained at about 7%, and 12%, respectively. The concentration of SO 2 in the flue gas after the initial stage of combustion is nearly zero. Furthermore, NO concentration

  7. Refractory experience in circulating fluidized bed combustors, Task 7. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Vincent, R.Q.

    1989-11-01

    This report describes the results of an investigation into the status of the design and selection of refractory materials for coal-fueled circulating fluidized-bed combustors. The survey concentrated on operating units in the United States manufactured by six different boiler vendors: Babcock and Wilcox, Combustion Engineering, Foster Wheeler, Keeler Dorr-Oliver, Pyropower, and Riley Stoker. Information was obtained from the boiler vendors, refractory suppliers and installers, and the owners/operators of over forty units. This work is in support of DOE`s Clean Coal Technology program, which includes circulating fluidized-bed technology as one of the selected concepts being evaluated.

  8. Exploratory and basic fluidized-bed combustion studies. Quarterly report, January-March 1980

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, I.; Myles, K.M.; Swift, W.M.

    1980-12-01

    This work supports development studies for both atmospheric and pressurized fluidized-bed coal combustion. Laboratory and process development studies are aimed at providing needed information on limestone utilization, removal of particulates and alkali metal compounds from the flue gas, control of SO/sub 2/ and trace pollutants emissions, and other aspects of fluidized-bed combustion. This report presents information on: (1) the development of a limestone utilization predictive methodology, (2) studies of particle breakup and elutriation, (3) basic studies on limestone sulfation enhancement by hydration, (4) studies of the kinetics of the hydration process, and (5) an investigation of various hydration process concepts.

  9. Fluidized bed combustion of low-grade coal and wastes: Research and development

    Energy Technology Data Exchange (ETDEWEB)

    Borodulya, V.A.; Dikalenko, V.I.; Palchonok, G.I.; Vinogradov, L.M. [Academy of Sciences of Belarus, Minsk (Belarus). A.V. Luikov Heat and Mass Transfer Inst.; Dobkin, S.M.; Telegin, E.M. [Special Design Office, Brest (Belarus)

    1994-12-31

    Experimental studies were carried out to investigate devolatilization of fuel as single spherical particles of wood, hydrolytic lignin, leather sewage sludge and Belarussian brown coals in a fluidized bed of sand. It is found that the devolatilization process depends on moisture and ash contents in fuel and on the external heat and mass transfer rate. The char combustion occurs largely in the intermediate region. Kinetic parameters of the devolatilization and char combustion are obtained. A low-capacity fluidized bed boiler suitable for combustion of coal and different wastes is described.

  10. Model-free adaptive control of supercritical circulating fluidized-bed boilers

    Science.gov (United States)

    Cheng, George Shu-Xing; Mulkey, Steven L

    2014-12-16

    A novel 3-Input-3-Output (3.times.3) Fuel-Air Ratio Model-Free Adaptive (MFA) controller is introduced, which can effectively control key process variables including Bed Temperature, Excess O2, and Furnace Negative Pressure of combustion processes of advanced boilers. A novel 7-input-7-output (7.times.7) MFA control system is also described for controlling a combined 3-Input-3-Output (3.times.3) process of Boiler-Turbine-Generator (BTG) units and a 5.times.5 CFB combustion process of advanced boilers. Those boilers include Circulating Fluidized-Bed (CFB) Boilers and Once-Through Supercritical Circulating Fluidized-Bed (OTSC CFB) Boilers.

  11. Fluidization Characteristics of Medium-High-Consistency Pulp Fiber Suspensions with an Impeller

    Directory of Open Access Journals (Sweden)

    Ye Daoxing

    2016-01-01

    Full Text Available When the mass concentration exceeds 7%, pulp suspensions stop flowing and act like a solid. To investigate the fluidization characteristics of medium-high-consistency pulp suspensions and achieve pulp fluidization and pumping, experiments were carried out with waste tissue pulp and unbleached kraft pulp. The objectives of this paper were to study the rheology of medium-high-consistency pulp and to determine accurate parameters for the physical Herschel-Bulkley model. To validate this model, computational fluid dynamics (CFD results were compared to experimental data. The simulation values were very similar and were in agreement with experimental results.

  12. The characterization of fluidization behavior using a novel multichamber microscale fluid bed

    DEFF Research Database (Denmark)

    Räsänen, Eetu; Rantanen, Jukka; Mannermaa, Jukka-Pekka

    2004-01-01

    In the preformulation stage, there is a special need to determine the process behavior of materials with smaller amounts of samples. The purpose of this study was to assemble a novel automated multichamber microscale fluid bed module with a process air control unit for the characterization...... of fluidization behavior in variable conditions. The results were evaluated on the basis of two common computational methods, the minimum fluidization velocity, and the Geldart classification. The materials studied were different particle sizes of glass beads, microcrystalline cellulose, and silicified......, the utilization of the computational predictions was restricted. The presented setup is a novel approach for studying process behavior with only a few grams of materials....

  13. Agglomeration mechanism in biomass fluidized bed combustion – Reaction between potassium carbonate and silica sand

    DEFF Research Database (Denmark)

    Anicic, Bozidar; Lin, Weigang; Dam-Johansen, Kim

    2018-01-01

    Agglomeration is one of the operational problems in fluidized bed combustion of biomass, which is caused by interaction between bed materials (e.g. silica sand) and the biomass ash with a high content of potassium species. However, the contribution of different potassium species to agglomeration......CO3 and silica sand, forming a thin product layer. The layer acted as a reactive media further reacting with K2CO3 and silica sand. The results provide a basis for understanding of potassium induced agglomeration process in fluidized bed biomass combustion....

  14. Thermo-hydrodynamic design of fluidized bed combustors estimating metal wastage

    CERN Document Server

    Lyczkowski, Robert W; Bouillard, Jacques X; Folga, Stephen M

    2012-01-01

    Thermo-Hydrodynamic Design of Fluidized Bed Combustors: Estimating Metal Wastage is a unique volume that finds that the most sensitive parameters affecting metal wastage are superficial fluidizing velocity, particle diameter, and particle sphericity.  Gross consistencies between disparate data sources using different techniques were found when the erosion rates are compared on the same basis using the concept of renormalization.  The simplified mechanistic models and correlations, when validated, can be used to renormalize any experimental data so they can be compared on a consistent basis using a master equation.

  15. Conversion of solid carbonaceous fuels in a fluidized bed fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Lee, A.C.; Li, S.; Mitchell, R.E.; Guer, T.M. [Stanford University, Stanford, CA (United States). Dept. of Mechanical Engineering

    2008-07-01

    A fluidized bed direct carbon fuel cell was employed to achieve direct conversion of solid fuels into electricity. Power was generated from pulverized Lower Kittanning (bituminous) coal, synthetic carbon, and biomass in a single process step. Current-voltage characteristics exhibited typical fuel cell behavior. Fluidization in flowing CO{sub 2} overcomes the difficulty of attaining solid fuel-to-anode contact and generates CO in situ via the Boudouard reaction. A mechanistic reaction pathway is proposed for anodic oxidation of the solid fuel. Conversion was verified by gas analysis of oxidation products in the flue stream and by oxygen mass balance.

  16. Pluto: Fluidized Transport of Tholins by Heating of the Subsurface

    Science.gov (United States)

    Cruikshank, Dale P.; Spohrer, Steven; Grundy, William M.; Moore, Jeffrey M.; Umurhan, Orkan M.; White, Oliver L.; Beyer, Ross A.; Dalle Ore, Cristina M.; Stern, S. A.; Young, Leslie; hide

    2017-01-01

    New Horizons images of Pluto show evidence of the transport of the colored non-ice component across the surface, with substantial accumulations in some areas of low elevation. The non-ice component is presumed to be tholin produced in the atmosphere as a precipitating aerosol, in the surface ices by photolysis or radiolysis, or both. We model the surface layer of N2 ice with varying amounts of incorporated tholin particles to explore the heating within the ice that occurs by the solid-state greenhouse effect. We find that in plausible models of the contaminated N2 surface ice the triple point temperature (63.15K) is reached at a depth of approximately less than 1m. At that depth the confining pressure of the ice column is much less than the triple point pressure (12.52 kPa), so N2 should convert to the gas phase, exerting pressure on the overburden. When the gas pressure exceeds the strength of the confining ice, a breakout on the surface will occur, fluidizing fragments of ice and its contaminants that are then free to flow downhill, rafted on entrained gas, similar in some ways to the pyroclastic volcanic phenomenon known as nuée ardente. The digital elevation map of Pluto made from stereo images shows some surface regions that may have been stripped of the N2 layer, exposing H2O ice (presumed to be bedrock) below, with a corresponding accumulation of dark material that was that was the previously entrained particulate tholin. Accumulations of tholin are found associated with some of the fossae, and some cover preexisting topography to depths of up to a few hundred meters.

  17. Database implementation to fluidized cracking catalytic-FCC process

    International Nuclear Information System (INIS)

    Santana, Antonio Otavio de; Dantas, Carlos Costa; Santos, Valdemir A. dos

    2009-01-01

    A process of Fluidized Cracking Catalytic (FCC) was developed by our research group. A cold model FCC unit, in laboratory scale, was used for obtaining of the data relative to the following parameters: air flow, system pressure, riser inlet pressure, rise outlet pressure, pressure drop in the riser, motor speed of catalyst injection and density. The measured of the density is made by gamma ray transmission. For the fact of the process of FCC not to have a database until then, the present work supplied this deficiency with the implementation of a database in connection with the Matlab software. The data from the FCC unit (laboratory model) are obtained as spreadsheet of the MS-Excel software. These spreadsheets were treated before importing them as database tables. The application of the process of normalization of database and the analysis done with the MS-Access in these spreadsheets treated revealed the need of an only relation (table) for to represent the database. The Database Manager System (DBMS) chosen has been the MS-Access by to satisfy our flow of data. The next step was the creation of the database, being built the table of data, the action query, selection query and the macro for to import data from the unit FCC in study. Also an interface between the application 'Database Toolbox' (Matlab2008a) and the database was created. This was obtained through the drivers ODBC (Open Data Base Connectivity). This interface allows the manipulation of the database by the users operating in the Matlab. (author)

  18. Pressurized fluidized-bed hydroretorting of Eastern oil shales

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, M.J.; Mensinger, M.C.; Rue, D.M.; Lau, F.S. (Institute of Gas Technology, Chicago, IL (United States)); Schultz, C.W. (Alabama Univ., University, AL (United States)); Parekh, B.K. (Kentucky Univ., Lexington, KY (United States)); Misra, M. (Nevada Univ., Reno, NV (United States)); Bonner, W.P. (Tennessee Technological Univ., Cookeville, TN (United States))

    1992-11-01

    The Devonian oil shales of the Eastern United States are a significant domestic energy resource. The overall objective of the multi-year program, initiated in October 1987 by the US Department of Energy is to perform the research necessary to develop the Pressurized Fluidized-Bed Hydroretorting (PFH) process for producing oil from Eastern oil shales. The program also incorporates research on technologies in areas such as raw shale preparation, beneficiation, product separation, and waste disposal that have the potential of improving the economics and/or environmental acceptability of recovering oil from oil shales using the PFH process. The results of the original 3-year program, which was concluded in May 1991, have been summarized in a four-volume final report published by IGT. DOE subsequently approved a 1-year extension to the program to further develop the PFH process specifically for application to beneficiated shale as feedstock. Studies have shown that beneficiated shale is the preferred feedstock for pressurized hydroretorting. The program extension is divided into the following active tasks. Task 3. testing of process improvement concepts; Task 4. beneficiation research; Task 5. operation of PFH on beneficiated shale; Task 6. environmental data and mitigation analyses; Task 7. sample procurement, preparation, and characterization; and Task 8. project management and reporting. In order to accomplish all the program objectives, the Institute of Gas Technology (IGT), the prime contractor, worked with four other institutions: the University of Alabama/Mineral Resources Institute (MRI), the University of Kentucky Center for Applied Energy Research (UK-CAER), the University of Nevada (UN) at Reno, and Tennessee Technological University (TTU). This report presents the work performed during the program extension from June 1, 1991 through May 31, 1992.

  19. Investigation of flow mechanisms in conical models of fluidized beds and transfer of the results to high-temperature-coating beds. A study on the coating of nuclear fuel particles in fluidized beds

    International Nuclear Information System (INIS)

    Kalthoff, B.; Gyarmati, E.; Nickel, H.

    The different states of movement of the fluid-solid particle system as occurring in coating of nuclear particle fuel in conical fluidized beds determine the transfer of momentum, heat and mass in the fluidized bed. To know the flow characteristics, therefore, is essential for the understanding of the complex processes which take place during coating. As experimental studies in actual coaters initially were impossible due to the high temperature levels of up to 2000 0 C, information on characteristic behavior of the fluidized bed was obtained from geometrically similar model beds. Based on principles in the mechanics of similarity the fluid-solid particle system was selected. Hence, results obtained in model tests could be correlated to hot fluidized beds by means of a dimensionless characteristic number describing the fluid-solid system. A second combination of characteristic numbers allows the characterization of the three states of a fluidizing regime, i.e., spouting, bubbling, and slugging. For examining the model test results in hot beds, a measuring device was developed applicable to both cold model beds and actual fluidized bed coaters; pressure oscillations originating in the beds could be made visible by means of electronics and their frequency measured. Coating experiments with different batches and at different temperature levels rendered this frequency to decrease with increase in bed height. Thus the frequency is an important index for the momentary state of fluidization of the fluid-solid particle system. (U.S.)

  20. Historia del Instituto de Investigaciones Cardiológicas Alberto C. Taquini en su 60° aniversario History of Instituto de Investigaciones Cardiológicas Alberto C. Taquini in its 60th anniversary

    OpenAIRE

    José Milei; José María Trujillo

    2004-01-01

    El Instituto de Investigaciones Cardiológicas (ININCA) está unido a la figura de quien fuera, desde su fundación, director por más de 50 años: Alberto C. Taquini. Allí se desarrolló (y se desarrolla) investigación y docencia. Se estudiaron, desde el inicio, la hipertensión arterial, la hipoxia y las adaptaciones hemodinámicas, la fisiología del riñón y los electrolitos, la pared arterial, el metabolismo cardíaco, la farmacología del miocardio y el papel regulador del sistema nervioso central ...

  1. La autopercepción de eficacia en la escritura: una revisión de investigaciones

    Directory of Open Access Journals (Sweden)

    Antonio GARCÍA GUZMÁN

    2009-11-01

    Full Text Available RESUMEN: En este artículo se presenta una revisión de investigaciones sobre la percepción que tienen los sujetos de su eficacia en la escritura. En el análisis de investigaciones se incluyeron los siguientes tópicos: 1 métodos de investigación utilizados; 2 variables que inciden en la autopercepción de la eficacia en la escritura (edad, sexo, nivel instructivo y dificultades en el aprendizaje; 3 relación de la autopercepción de eficacia en la escritura con la motivación, las expectativas de resultados y las causas de atribución; 4 resultados más relevantes en la investigación; 5 aspectos no clarificados, que deberían abordarse en futuras investigaciones.ABSTRACT: This paper deals with a review of research on self-efficacy beliefs in writing. Different issues in this research review were analyzed: 1 methods that were applied in research; 2 variables related to self-efficacy in writing, such as age, gender, instructional level and learning disabilities; 3 the relationship of self-efficacy in writing with motivation, results expectancy and attribution beliefs; 4 relevant results obtained in research; 5 some issues, not yet explained, which must be approached in forthcoming research.RÉSUMÉ: Dans cet article, une revisión des recherches sur la perception que les eleves ont de leur réussite a l'écrit est présentée. Divers aspects on été analysés: 1 la méthodologie de la recherche; 2 les variables dont la perception de la réussite depende: age, genre, niveau d'instruction et difficultés d'apprentissage; 3 la relation entre la perception de la réussite et la motivation, l'expectative de résultats et les jugements d'attribution; 4 les résultats les plus remarquables ayant été obtenus dans la recherche; 5 les aspects non clarines devant étre abordes dans des recherches futures.

  2. El discurso cienti??fico en la investigacio??n educativa en Latinoame??rica: el caso de Me??xico

    OpenAIRE

    Castellanos Quintero, Sara Julia

    2011-01-01

    En este arti??culo se presenta el estado del arte del ana??lisis del discurso cienti??fico en la investigacio??n educativa en Me??xico, particularmente en el disen??o y desarrollo del curri??culo. La investigacio??n en el a??rea del curri??culo universitario comenzo?? en Me??xico en los an??os 80. El discurso estaba orientado hacia la bu??squeda de modelos y me??todos de ensen??anza y evaluacio??n, la implementacio??n del practicum y la correspondencia entre la formacio??n profesional y el em...

  3. CFD Analysis to Calculate the Optimal Air Velocity in Drying Green Tea Process Using Fluidized Bed Dryer

    Science.gov (United States)

    Yohana, Eflita; Nugraha, Afif Prasetya; Diana, Ade Eva; Mahawan, Ilham; Nugroho, Sri

    2018-02-01

    Tea processing is basically distinguished into three types which black tea, green tea, and oolong tea. Green tea is processed by heating and drying the leaves. Green tea factories in Indonesia are generally using the process of drying by panning the leaves. It is more recommended to use the fluidization process to speed up the drying process as the quality of the tea can be maintained. Bubbling fluidization is expected to occur in this research. It is a process of bubbles are formed in the fluidization. The effectiveness of the drying process in a fluidized bed dryer machine needs to be improved by using a CFD simulation method to proof that umf < u < ut, where the average velocity value is limited by the minimum and the maximum velocity of the calculation the experimental data. The minimum and the maximum velocity value of the fluidization is 0.96 m/s and 8.2 m/s. The result of the simulation obtained that the average velocity of the upper bed part is 1.81 m/s. From the results obtained, it can be concluded that the calculation and the simulation data is in accordance with the condition of bubbling fluidization in fluidized bed dryer.

  4. CFD Analysis to Calculate the Optimal Air Velocity in Drying Green Tea Process Using Fluidized Bed Dryer

    Directory of Open Access Journals (Sweden)

    Yohana Eflita

    2018-01-01

    Full Text Available Tea processing is basically distinguished into three types which black tea, green tea, and oolong tea. Green tea is processed by heating and drying the leaves. Green tea factories in Indonesia are generally using the process of drying by panning the leaves. It is more recommended to use the fluidization process to speed up the drying process as the quality of the tea can be maintained. Bubbling fluidization is expected to occur in this research. It is a process of bubbles are formed in the fluidization. The effectiveness of the drying process in a fluidized bed dryer machine needs to be improved by using a CFD simulation method to proof that umf < u < ut, where the average velocity value is limited by the minimum and the maximum velocity of the calculation the experimental data. The minimum and the maximum velocity value of the fluidization is 0.96 m/s and 8.2 m/s. The result of the simulation obtained that the average velocity of the upper bed part is 1.81 m/s. From the results obtained, it can be concluded that the calculation and the simulation data is in accordance with the condition of bubbling fluidization in fluidized bed dryer.

  5. Measuring the electric energy services for the World Trade Center in Mexico city; Medicion de los servicios de energia electrica del World Trade Center de la ciudad de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez Nunez, Humberto; Robledo Vera, Humberto [Luz y Fuerza del Centro, Mexico, D. F. (Mexico)

    1997-12-31

    In conforming the project of measuring the electric power for the World Trade Center of Mexico City, the use of top technology has been considered that in its field represents the application for the first time in our country the automatic reading of the electric energy meters. In this paper the network for the supply of electric power to the World Trade Center is described as well as the measuring systems of this building and mention is made of the characteristics of the system components and the advantages of remote reading. General data is provided on this collection of buildings, the connections in its tower and a feeding one line diagram of the tower itself [Espanol] En la conformacion del proyecto de medicion de la energia electrica para el edificio World Trade Center de la Ciudad de Mexico, se ha considerado el uso de tecnologia de punta que en su campo representa la aplicacion por primera vez en nuestro pais de la lectura automatica de medidores de energia electrica. En esta ponencia se describen la red de suministro al World Trade Center, los sistemas de medicion de este edificio y se mencionan las caracteristicas de los componentes del sistema y las ventajas de las lecturas remotas. Se proporciona datos generales sobre el conjunto de este edificio, las derivaciones en su torre y un diagrama unifilar de alimentacion de la torre del mismo

  6. The optimization of electric motors repair techniques as a mean for electric energy saving; La optimizacion de las tecnicas de reparacion de motores electricos como un medio para ahorrar energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Zagal Leon, Juan Ruben [Fideicomiso para el Ahorro de Energia Electrica (FIDE), Mexico, D. F. (Mexico)

    1998-12-31

    This paper presents, in a very concise, which are the techniques to optimize the electric motors repair made by the Fideicomiso para el Ahorro de Energia Electrica (FIDE), the loss of efficiency that might exist after repairing an electric motor, as well as the procedures to perform an optimum reparation of the electric motors. Furthermore, some recommendations are given for the selection of an adequate rewinding shop to guarantee that the motor does not suffer efficiency losses after its repair. [Espanol] Este trabajo presenta, de manera muy concreta, cuales son las tecnicas para optimizar las tecnicas de reparacion de motores electricos realizado por el Fideicomiso para el Ahorro de Energia Electrica (FIDE), el nivel de perdida de eficiencia que puede existir despues de reparar un motor electrico, asi como los procedimientos para realizar una optima reparacion en motores electricos. Asimismo, se proporcionan algunas recomendaciones para seleccionar un taller de reembobinado adecuado para garantizar que el motor no sufra perdidas de eficiencia despues de su reparacion.

  7. Formación de saberes políticos: aportes de investigaciones psicológicas

    OpenAIRE

    Lenzi, Alicia; D'Avirro, María Julieta; Pataro, María Alejandra; Areste, María Silvina

    2007-01-01

    Se examina la cuestión de los saberes políticos en niños, jóvenes y adultos, desde las contribuciones de investigaciones de la psicología del desarrollo y la psicología educacional, con ciertas referencias a la psicología social y política. Subyace a esta cuestión el polémico concepto de ciudadanía y concepciones divergentes acerca de la formación ciudadana y sus prácticas. La literatura especializada revela una creciente preocupación por la formación de los futuros ciudadanos ante la mundial...

  8. Análisis, diagnóstico y perspectivas de la investigacion psicoeducacional en el Perú

    Directory of Open Access Journals (Sweden)

    Carmen Lazarte Torriani

    1991-06-01

    Full Text Available El artículo sistematiza la investigación realizada por la Psicología Educacional Peruana. Se revisan tesis, algunas memorias, resúmenes e informes de investigación y de congresos, catálogos, diagnósticos educacionales, revisiones publicadas, artículos de revistas y algunos libros. Se describen las etapas de la investigación psicoeducacional y se caracterizan investigaciones de tesis, de publicaciones y de INIDE en base a una serie de criterios. Finalmente, se arriba a un diagnóstico de la investigación psicoeducacional en el Perú y se trazan sus perspectivas.

  9. Matrix solution of point kinetic equation in a fluidized bed nuclear reactor

    International Nuclear Information System (INIS)

    Vilhena, M.T. de; Claeyssen, J.R.

    1990-01-01

    The purpose of this work is to solve the point kinetic equation for a Fluidized Bed Nuclear Reactor by matrix series formulation, showing it is a simple and accurate method, observing this is a scale problem of Stiff type for small time. (author)

  10. Membrane assisted fluidized bed reactor: experimental demonstration for partial oxidation of methanol

    NARCIS (Netherlands)

    Deshmukh, S.A.R.K.

    2004-01-01

    In this thesis the reactor concept has been developed on the basis of an experimental study on the effect of fluidization conditions on the membrane permeation rate in a MAFBR, the extent of gas back mixing and the tube-to-bed heat transfer rates in the presence of membrane bundles with and without

  11. PET investigation of a fluidized particle : spatial and temporal resolution and short term motion

    NARCIS (Netherlands)

    Hoffmann, AC; Dechsiri, C; van de Wiel, F; Dehling, HG

    The motion of a single particle in a fluidized bed has been followed with high temporal and spatial resolution using an ECAT EXACT HR+ PET camera. An account is given of the analysis of the output from the camera, and the calculation of the particle position. The particle position was determined

  12. Conceptual design of a fluidized bed nuclear reactor : Statics, dynamics and safety-related aspects

    NARCIS (Netherlands)

    Agung, A.

    2007-01-01

    In this thesis a conceptual design of an innovative high temperature reactor based on the fluidization principle (FLUBER) is proposed. The reactor should satisfy the following requirements: (a) modular and low power, (b)) large shutdown margin, (c) able to produce power when the bed of particles

  13. Application of point kinetic model in the study of fluidized bed reactor dynamic

    International Nuclear Information System (INIS)

    Borges, Volnei; Vilhena, Marco Tullio de; Streck, Elaine E.

    1995-01-01

    In this work the dynamical behavior of the fluidized bed nuclear reactor is analysed. The main goal consist to study the effect of the acceleration term in the point kinetic equations. Numerical simulations are reported considering constant acceleration. (author). 7 refs, 4 figs

  14. A discrete particle simulation study on the influence of restitution coefficient on spout fluidized bed dynamics

    NARCIS (Netherlands)

    van Buijtenen, M.S.; Deen, N.G.; Heinrich, Stefan; Antonyuk, Sergiy; Kuipers, J.A.M.

    2009-01-01

    Spout fluidized beds find widespread application in the process industry in granulation processes, in which efficient contacting between large particles, droplets and gas is of paramount importance. However, detailed understanding of the complex behavior of these systems is lacking. In this paper,

  15. Improvement of the discrete element model for the study of granulation in a spout fluidized bed

    NARCIS (Netherlands)

    van Buijtenen, M.S.; Deen, N.G.; Heinrich, Stefan; Kuipers, J.A.M.; Antonyuk, Sergiy

    2007-01-01

    Spout fluidized beds find widespread application in the process industry in granulation processes, in which efficient contacting between large particles, droplets and gas is of paramount importance. However, detailed understanding of the complex behavior of these systems is lacking. In this paper we

  16. Monitoring granulation rate processes using three PAT tools in a pilot-scale fluidized bed.

    Science.gov (United States)

    Tok, Ai Tee; Goh, Xueping; Ng, Wai Kiong; Tan, Reginald B H

    2008-01-01

    The purpose of this research was to analyze and compare the responses of three Process Analytical Technology (PAT) techniques applied simultaneously to monitor a pilot-scale fluidized bed granulation process. Real-time measurements using focused beam reflectance measurement (Lasentec FBRM) and near-infra red spectroscopy (Bruker NIR) were taken by inserting in-line probes into the fluidized bed. Non-intrusive acoustic emission measurements (Physical Acoustic AE) were performed by attaching piezoelectric sensors on the external wall of the fluidized bed. Powder samples were collected at regular intervals during the granulation process and characterized offline using laser diffraction, scanning electron microscopy, stereo-optical microscopy and loss on drying method. PAT data comprising chord length distribution and chord count (from FBRM), absorption spectra (from NIR) and average signal levels and counts (from AE) were compared with the particle properties measured using offline samples. All three PAT techniques were able to detect the three granulation regimes or rate processes (wetting and nucleation, consolidation and growth, breakage) to varying degrees of sensitivity. Being dependent on optical signals, the sensitivities of the FBRM and NIR techniques were susceptible to fouling on probe windows. The AE technique was sensitive to background fluidizing air flows and external interferences. The sensitivity, strengths and weaknesses of the PAT techniques examined may facilitate the selection of suitable PAT tools for process development and scale-up studies.

  17. Building population balance model for fluidized bed melt granulation: lessons from kinetic theory of granular flow

    NARCIS (Netherlands)

    Tan, H.S.; Goldschmidt, M.J.V.; Boerefijn, R.; Hounslow, M.J.; Salman, A.; Kuipers, J.A.M.

    2004-01-01

    The purpose of this paper is to develop a theoretically sound basis for the equi-partition of kinetic energy (EKE) kernel recently developed by our group to describe the evolution of granule size distributions in fluidized bed granulation. The approach taken is to show first by distinct element

  18. Investigation on side-spray fluidized bed granulation with swirling airflow.

    Science.gov (United States)

    Wong, Poh Mun; Chan, Lai Wah; Heng, Paul Wan Sia

    2013-03-01

    Top-spray fluidized bed granulation with axial fluidization airflow from the bottom of the granulator is well-established in the pharmaceutical industry. The application of swirling airflow for fluidized bed granulation was more recently introduced. This study examined the effects of various process parameters on the granules produced by side-spray fluidized bed with swirling airflow using the central composite and Box-Behnken design of experiment. Influence of the amount of binder solution, spray rate, and distance between spray nozzle and powder bed were initially studied to establish operationally viable values for these parameters. This was followed by an in-depth investigation on the effects of inlet airflow rate, atomizing air pressure and distance between spray nozzle and powder bed on granule properties. It was found that the amount of binder solution had a positive correlation with granule size and percentage of lumps but a negative correlation with size distribution and Hausner ratio of the granules. Binder solution spray rate was also found to affect the granules size. High drug content uniformity was observed in all the batches of granules produced. Both inlet airflow rate and atomizing air pressure were found to correlate negatively with granule size and percentage of lumps but correlate positively with the size distribution of the granule produced. Percentage of fines was found to be significantly affected by inlet airflow rate. Distance between spray nozzle and powder bed generally affected the percentage of lumps.

  19. Investigation on Calcination Behaviors of Coal Gangue by Fluidized Calcination in Comparison with Static Calcination

    Directory of Open Access Journals (Sweden)

    Shuai Yuan

    2017-02-01

    Full Text Available In order to comprehensively utilize coal gangue, we present fluidized calcination as a new thermal technology for activating coal gangue and systematical study was conducted in comparison with static calcination. The calcined products obtained by different calcination methods under various temperatures were characterized by the means of X-ray diffraction (XRD, thermal gravimetry-differential scanning calorimeter (TG-DSC, Fourier transform-infrared spectroscopy (FT-IR and scanning electron microscope-energy dispersive spectrometer (SEM-EDS. Chemical and physical characteristics such as aluminium leaching rate, chemical oxygen demand and whiteness of calcined products were also investigated. The results show that aluminium leaching rate could reach to the maximal value 74.42% at 500 °C by fluidized calcination, while the maximal value of 66.33% could be reached at 600 °C by static calcination. Products by fluidized calcination obtained higher whiteness and lower chemical oxygen demand (COD under the same calcination temperature. The well-crystallized kaolinite transform to amorphous meta-kaolinite under 600 °C and mullite presence under 1000 °C according to phase transformation, chemical bond variation and microstructure evolution analysis. Fluidized calcination was more efficiently for combustion of carbon/organic matter and dehydroxylation of kaolinite, which might applied in coal gangue industry in future.

  20. Thermal gasification of village rice husk and sawdust in fluidized bed : gasifier operation and thermal efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Gangavati, P.B. [Basaveshwar Engineering College, Bagalkot (India); Mishra, I.M.; Prasad, B. [Indian Inst. of Technology, Roorkee (India). Dept. of Chemical Engineering

    2006-07-01

    An air gasification process for converting rice husks into a renewable fuel was presented. The gasification process was conducted on a fluidized bed gasifier unit comprised of a fluidized bed reactor; an air supply unit; biomass-feeding unit; a high efficiency cyclone; and an after-burner. The performance of the gasifier was evaluated under a range of different operating conditions, fluidization velocities, and equivalence ratios. The aim of the study was to understand the gasification characteristics of the rice husk and compare it with the kinetic behaviour of sawdust. Temperature profiles were analyzed, as well as gas composition and heating values, as well as carbon conversion and thermal efficiencies. The results of the gasification experiments indicated that thermal efficiencies decreased as the fluidization velocity increased. The gas yield increased and the higher heating values decreased with increases in the equivalence ratio (ER) at all the tested velocities. A maximum efficiency of approximately 57 per cent was obtained for the village rice husk, while efficiencies of 72.3 per cent were obtained for the sawdust. 7 ref., 2 figs.

  1. Air gasification of rice husk in a dual distributor type fluidized bed gasifier

    Energy Technology Data Exchange (ETDEWEB)

    Mansaray, K.G.; Ghaly, A.E. [Dalhousie University, Halifax, Nova Scotia (Canada). Biological Engineering Dept.; Al-Taweel, A.M. [Dalhousie University, Halifax, Nova Scotia (Canada). Chemical Engineering Dept.; Hamdullahpur, F.; Ugursal, V.I. [Dalhousie University, Halifax, Nova Scotia (Canada). Mechanical Engineering Dept.

    1999-10-01

    In this study, a dual distributor type fluidized bed gasifier was used for the air gasification of rice husk in view of producing fuel gas. The effects of varying fluidization velocity (0.22, 0.28 and 0.33 m s{sup -1}) and equivalence ratio (0.25, 0.30 and 0.35) on the gasifier performance were discussed. The steady state temperature varied between 665 and 830 degrees C. The fluidization velocity of 0.22 m s{sup -1} and equivalence ratio of 0.25 appeared to be the optimum conditions with respect to the quality of gas. The mole fractions of the combustible components reached their maximum values at these conditions with a typical gas composition of 4% H{sub 2}, 5% hydrocarbons (CH{sub 4}, C{sub 2}H{sub 2}, C{sub 2}H{sub 4} and C{sub 2}H{sub 6}), 15% CO{sub 2}, 20% CO and 57% N{sub 2}. The higher heating value of the gas obtained at these fluidization velocity and equivalence ratio (3.09 - 5.03 MJ Nm{sup -3}) compared very well with published data from air-blown biomass gasifiers of similar scale of operation. The gas yield and carbon conversion were in the range of 1.30 to 1.98 Nm{sup 3} kg{sup -1} and 55.0 to 81.0%, respectively.

  2. Fast pyrolysis of biomass in a fluidized bed reactor: in-situ filtering of the vapors

    NARCIS (Netherlands)

    Hoekstra, E.; Hogendoorn, Kees; Wang, X.; Westerhof, Roel Johannes Maria; Kersten, Sascha R.A.; van Swaaij, Willibrordus Petrus Maria; Groeneveld, M.J.

    2009-01-01

    A system to remove in situ char/ash from hot pyrolysis vapors has been developed and tested at the University of Twente. The system consists of a continuous fluidized bed reactor (0.7 kg/h) with immersed filters (wire mesh, pore size 5 μm) for extracting pyrolysis vapors. Integration of the filter

  3. Safe design and operation of fluidized-bed reactors: Choice between reactor models

    NARCIS (Netherlands)

    Westerink, E.J.; Westerterp, K.R.

    1990-01-01

    For three different catalytic fluidized bed reactor models, two models presented by Werther and a model presented by van Deemter, the region of safe and unique operation for a chosen reaction system was investigated. Three reaction systems were used: the oxidation of benzene to maleic anhydride, the

  4. [Analysis of novel style biological fluidized bed A/O combined process in dyeing wastewater treatment].

    Science.gov (United States)

    Wei, Chao-Hai; Huang, Hui-Jing; Ren, Yuan; Wu, Chao-Fei; Wu, Hai-Zhen; Lu, Bin

    2011-04-01

    A novel biological fluidized bed was designed and developed to deal with high-concentration refractory organic industrial wastewater. From 12 successful projects, three cases of dyeing wastewater treatment projects with the scale of 1200, 2000 and 13000 m3/d respectively were selected to analyze the principle of treating refractory organic wastewater with fluidized bed technology and discuss the superiority of self-developed biological fluidized bed from the aspects of technical and economic feasibility. In the three cases, when the hydraulic retention time (HRT) of biological system were 23, 34 and 21. 8 h, and the volume loading of influents (COD) were 1.75, 4.75 and 2.97 kg/(m3 x d), the corresponding COD removal were 97.3%, 98.1% and 95.8%. Furthermore the operating costs of projects were 0.91, 1.17 and 0.88 yuan per ton of water respectively. The index of effluent all met the 1st grade of Guangdong Province wastewater discharge standard. Results showed that the biological fluidized bed had characteristics of shorter retention time, greater oxygen utilization rate, faster conversion rate of organic pollutants and less sludge production, which made it overcome the shortcomings of traditional methods in printing and dyeing wastewater treatment. Considering the development of technology and the combination of ecological security and recycling resources, a low-carbon wastewater treatment process was proposed.

  5. Industrial Scale Synthesis of Carbon Nanotubes Via Fluidized Bed Chemical Vapor Deposition: A Senior Design Project

    Science.gov (United States)

    Smith, York R.; Fuchs, Alan; Meyyappan, M.

    2010-01-01

    Senior year chemical engineering students designed a process to produce 10 000 tonnes per annum of single wall carbon nanotubes (SWNT) and also conducted bench-top experiments to synthesize SWNTs via fluidized bed chemical vapor deposition techniques. This was an excellent pedagogical experience because it related to the type of real world design…

  6. Modelling of NOx emissions from pressurized fluidized bed combustion - A parameter study

    DEFF Research Database (Denmark)

    Jensen, Anker; Johnsson, Jan Erik

    1997-01-01

    Simulations with a mathematical model of a pressurized bubbling fluidized-bed combustor (PFBC) combined with a kinetic model for NO formation and reduction are reported. The kinetic model for NO formation and reduction considers NO and NH3 as the fixed nitrogen species, and includes homogeneous r...

  7. FLUIDIZED BED STEAM REFORMING FOR TREATMENT AND IMMOBILIZATION OF LOW-ACTIVITY WASTE

    Energy Technology Data Exchange (ETDEWEB)

    HEWITT WM

    2011-04-08

    This report is one of four reports written to provide background information regarding immobilization technologies remaining under consideration for supplemental immobilization of Hanford's low-activity waste. This paper provides the reader a general understanding of fluidized bed steam reforming and its possible application to treat and immobilize Hanford low-activity waste.

  8. Fluidized Bed Steam Reforming For Treatment And Immobilization Of Low-Activity Waste

    International Nuclear Information System (INIS)

    Hewitt, W.M.

    2011-01-01

    This report is one of four reports written to provide background information regarding immobilization technologies remaining under consideration for supplemental immobilization of Hanford's low-activity waste. This paper provides the reader a general understanding of fluidized bed steam reforming and its possible application to treat and immobilize Hanford low-activity waste.

  9. Application of image processing on struvite recovery from swine wastewater by using the fluidized bed.

    Science.gov (United States)

    Ye, Zhi-Long; Deng, Yujun; Ye, Xin; Lou, Yaoyin; Chen, Shaohua

    2018-01-01

    Fluidized granulation is one of the common methods used in wastewater treatment and resource recovery with harvesting millimeter-scale large particles. Presently, effective methods are lacking to measure the fluidized granules ranging from micro- to millimeter scales, with the consequence of ineffectively controlling and optimizing the granulation process. In this work, recovering struvite (MgNH 4 PO 4 ·6H 2 O) from swine wastewater by using a fluidized bed was taken as an example. Image processing was applied to analyze the properties of different types of struvite granules, including morphology, particle size distribution, number density and mass concentration. Four stages of the struvite crystal evolution were therefore defined: aggregation, aggregate compaction, cluster-agglomerating and coating growth. These stages could occur simultaneously or sequentially. Up-flow rates of 30-80 mm/s in the fluidized bed sustained 600-876 g/L granular solids. Results revealed that the coating-growth granules were formed with compact aggregates or cluster-agglomerating granules as the nuclei. The growth rates for the different types of particles, including population growth, mass increase and particle size enlargement, were determined. In final, a schematic illustration for struvite granulation process is also presented.

  10. A numerical study of fluidization behavior of Geldart A particles using a discrete particle model

    NARCIS (Netherlands)

    Ye, M.; van der Hoef, Martin Anton; Kuipers, J.A.M.

    2004-01-01

    This paper reports on a numerical study of fluidization behavior of Geldart A particles by use of a 2D soft-sphere discrete particle model (DPM). Some typical features, including the homogeneous expansion, gross particle circulation in the absence of bubbles, and fast bubbles, can be clearly

  11. Effects of fluidized gas desulfurization (FGD) gypsum on non-target freshwater and sediment dwelling organims

    Science.gov (United States)

    Fluidized gas desulfurization gypsum is a popular agricultural soil amendment used to increase calcium and sulfur contents, and reduce aluminum toxicity. Due to its surface application in conservation tillage systems and high solubility, the soluble components of gypsum may be transferred with agri...

  12. Study of a 30 MW bubbling fluidized bed combustor based on co ...

    Indian Academy of Sciences (India)

    Power generation based on biomass holds a considerable promise in Punjab, which has huge biomass resources from crop production system and agro industries. ... ever, there are some biomass residues concentrated at specific locations, where demand for energy also exists. Fluidized-bed combustion process seems to ...

  13. Behaviour of Inorganic Constituents of Municipal Sewage Sludge during Fluidized-Bed Combustion.

    Czech Academy of Sciences Publication Activity Database

    Hartman, Miloslav; Pohořelý, Michael; Trnka, Otakar

    2007-01-01

    Roč. 61, 3 (2007) , s. 181-185 ISSN 0366-6352 R&D Projects: GA AV ČR(CZ) IAA4072201 Institutional research plan: CEZ:AV0Z40720504 Keywords : sewage sludge * heavy metals * fluidized-bed combustion Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 0.367, year: 2007

  14. Development of pressurized internally circulating fluidized bed combustion technology; Kaatsu naibu junkan ryudosho boiler no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, I. [Center for Coal Utilization, Japan, Tokyo (Japan); Nagato, S.; Toyoda, S. [Ebara Corp., Tokyo (Japan)

    1996-09-01

    The paper introduced support research on element technology needed for the design of hot models of the pressurized internally circulating fluidized bed combustion boiler in fiscal 1995 and specifications for testing facilities of 4MWt hot models after finishing the basic plan. The support research was conduced as follows: (a) In the test for analysis of cold model fluidization, it was confirmed that each characteristic value of hot models is higher than the target value. Further, calculation parameters required for computer simulation were measured and data on the design of air diffusion nozzle for 1 chamber wind box were sampled. (b) In the CWP conveyance characteristic survey, it was confirmed that it is possible to produce CWP having favorable properties. It was also confirmed that favorable conveyability can be maintained even if the piping size was reduced down to 25A. (c) In the gas pressure reducing test, basic data required for the design of gas pressure reducing equipment were sampled. Specifications for the fluidized bed combustion boiler of hot models are as follows: evaporation amount: 3070kg/h, steam pressure: 1.77MPa, fuel supply amount: 600kg-coal/h, boiler body: cylinder shape water tube internally circulating fluidized bed combustion boiler. 4 refs., 4 figs.

  15. Combustion of Liquid Bio-Fuels in an Internal Circulating Fluidized Bed

    Czech Academy of Sciences Publication Activity Database

    Miccio, F.; Kalisz, S.; Baxter, D.; Svoboda, Karel

    2008-01-01

    Roč. 143, 1-3 (2008), s. 172-179 ISSN 1385-8947 Institutional research plan: CEZ:AV0Z40720504 Keywords : internal circulating fluidized bed * liquid fuel * combustion Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 2.813, year: 2008

  16. Transient Catalytic Activity of Calcined Dolomitic Limestone in a Fluidized Bed during Gasification of Woody Biomass.

    Czech Academy of Sciences Publication Activity Database

    Pohořelý, Michael; Jeremiáš, Michal; Skoblia, S.; Beňo, Z.; Šyc, Michal; Svoboda, Karel

    2016-01-01

    Roč. 30, č. 5 (2016), s. 4065-4071 ISSN 0887-0624 R&D Projects: GA ČR GC14-09692J Institutional support: RVO:67985858 Keywords : fluidized- bed gasification * woody biomass * limestone Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 3.091, year: 2016

  17. A Review of Eulerian Simulation of Geldart A Particles in Gas-Fluidized Beds

    NARCIS (Netherlands)

    Wang, J.

    2009-01-01

    Although great progress has been made in modeling the gas fluidization of Geldart B and D particles and dilute gas−solid flow by standard Eulerian approach, researchers have shown that, because of the limitation of computational resources and the formation of subgrid-scale (SGS) heterogeneous

  18. Fluidized bed electrodes with high carbon loading for water desalination by capacitive deionization

    NARCIS (Netherlands)

    Doornbusch, G.J.; Dykstra, J.E.; Biesheuvel, P.M.; Suss, M.E.

    2016-01-01

    The use of carbon flow electrodes has significantly impacted electrochemical energy storage and capacitive deionization (CDI), but device performance is limited as these electrodes cannot surpass ∼20 wt% carbon while maintaining flowability. We here introduce flowable fluidized bed electrodes

  19. The Role of Membrane Fluidization in the Gel-Assisted Formation of Giant Polymersomes.

    Directory of Open Access Journals (Sweden)

    Adrienne C Greene

    Full Text Available Polymersomes are being widely explored as synthetic analogs of lipid vesicles based on their enhanced stability and potential uses in a wide variety of applications in (e.g., drug delivery, cell analogs, etc.. Controlled formation of giant polymersomes for use in membrane studies and cell mimetic systems, however, is currently limited by low-yield production methodologies. Here, we describe for the first time, how the size distribution of giant poly(ethylene glycol-poly(butadiene (PEO-PBD polymersomes formed by gel-assisted rehydration may be controlled based on membrane fluidization. We first show that the average diameter and size distribution of PEO-PBD polymersomes may be readily increased by increasing the temperature of the rehydration solution. Further, we describe a correlative relationship between polymersome size and membrane fluidization through the addition of sucrose during rehydration, enabling the formation of PEO-PBD polymersomes with a range of diameters, including giant-sized vesicles (>100 μm. This correlative relationship suggests that sucrose may function as a small molecule fluidizer during rehydration, enhancing polymer diffusivity during formation and increasing polymersome size. Overall the ability to easily regulate the size of PEO-PBD polymersomes based on membrane fluidity, either through temperature or fluidizers, has broadly applicability in areas including targeted therapeutic delivery and synthetic biology.

  20. Development program on pressurized fluidized-bed combustion. Annual report, July 1, 1974--June 30, 1975

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, G.J.; Cunningham, P.; Fischer, J.

    1975-07-01

    The feasibility of using fluidized-bed combustors in power and steam plants is being evaluated. The concept involves burning fuels such as coal in a fluidized bed of either a naturally occurring, calcium-containing limestone or dolomite or in a synthetically prepared calcium-containing stone. The calcium oxide in the stone reacts with the sulfur released during combustion to form calcium sulfate, which remains in the bed, thus decreasing the level of SO/sub 2/ in the flue gas. Levels of NO/sub x/ in the flue gas are also low. The effect of operating variables and type of stone on the levels of SO/sub 2/ and NO/sub x/ is being determined. Behavior of trace elements during combustion has been preliminarily evaluated. The properties of a fluidized bed at minimum fluidization at different temperatures and pressures have been determined. The CaSO/sub 4/ produced in the combustion process is regenerated to CaO for reuse in the combustor by reductive decomposition at 1095/sup 0/C (2000/sup 0/F). The effects of operating variables on sulfur release during regeneration are being evaluated. Another regeneration process, solid-solid reaction of CaSO/sub 4/ with CaS, is also being investigated. Fundamental investigations of the kinetics of sulfation and regeneration reactions for the natural and synthetic stones are continuing. A model for the sulfation reaction is presented. The status of the new combustor andancillary regenerator equipment is discussed. (auth)

  1. High-Temperature Reaction in the Freeboard Region above a Bubbling Fluidized Bed

    Czech Academy of Sciences Publication Activity Database

    Hartman, Miloslav; Trnka, Otakar; Pohořelý, Michael; Svoboda, Karel

    2010-01-01

    Roč. 49, č. 6 (2010), s. 2672-2980 ISSN 0888-5885 R&D Projects: GA AV ČR IAA400720701 Institutional research plan: CEZ:AV0Z40720504 Keywords : fluidization * freeboard * performance Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 2.071, year: 2010

  2. Thermal Analysis of Fluidized Bed and Fixed Bed Latent Heat Thermal Storage System

    Science.gov (United States)

    Beemkumar, N.; Karthikeyan, A.; Shiva Keshava Reddy, Kota; Rajesh, Kona; Anderson, A.

    2017-05-01

    Thermal energy storage technology is essential because its stores available energy at low cost. Objective of the work is to store the thermal energy in a most efficient method. This work is deal with thermal analysis of fluidized bed and fixed bed latent heat thermal storage (LHTS) system with different encapsulation materials (aluminium, brass and copper). D-Mannitol has been used as phase change material (PCM). Encapsulation material which is in orbicular shape with 4 inch diameter and 2 mm thickness orbicular shaped product is used. Therminol-66 is used as a heat transfer fluid (HTF). Arrangement of encapsulation material is done in two ways namely fluidized bed and fixed bed thermal storage system. Comparison was made between the performance of fixed bed and fluidized bed with different encapsulation material. It is observed that from the economical point of view aluminium in fluidized bed LHTS System has highest efficiency than copper and brass. The thermal energy storage system can be analyzed with fixed bed by varying mass flow rate of oil paves a way to find effective heat energy transfer.

  3. Bed agglomeration in fluidized combustor fueled by wood and rice straw blends

    NARCIS (Netherlands)

    Thy, P.; Jenkins, B.M.; Williams, R.B.; Lesher, C.E.; Bakker, R.R.

    2010-01-01

    Petrographic techniques have been used to examine bed materials from fluidized bed combustion experiments that utilized wood and rice straw fuel blends. The experiments were conducted using a laboratory-scale combustor with mullite sand beds, firing temperatures of 840 to 1030 °C, and run durations

  4. El órgano de investigaciones criminalísticas en el contexto de las campañas securitarias

    Directory of Open Access Journals (Sweden)

    Keymer Guaicaipuro Ávila

    2014-03-01

    Full Text Available Normal 0 21 false false false ES X-NONE X-NONE ¿Las lógicas securitarias deben guiar las reformas legislativas que afectan al órgano de investigaciones criminalísticas? ¿Éstas deben afectar también la dirección que ejerce el Ministerio Público sobre la investigación penal? ¿El órgano de investigaciones debe ser considerado como una policía más? O, por el contrario, ¿tiene características propias que le diferencian de la institución policial? ¿La investigación penal debe ser entendida como parte del servicio de policía o como una fase del proceso penal? Del enfoque de las respuestas a estas interrogantes y de la precisión conceptual de los distintos términos empleados en estas áreas dependen importantes decisiones políticas, que pueden contribuir a la construcción del Estado Social de Derecho y de Justicia consagrado en la Constitución, o por el contrario, pueden coadyuvar también al fortalecimiento del Estado de Policía que subyace latente en todos los Estados de Derecho. En este trabajo se intentan hacer estas reflexiones desde el contexto venezolano, analizando críticamente la reciente legislación que ha introducido modificaciones en estas materias. 

  5. Experiment and modeling of low-concentration methane catalytic combustion in a fluidized bed reactor

    International Nuclear Information System (INIS)

    Yang, Zhongqing; Yang, Peng; Zhang, Li; Guo, Mingnv; Ran, Jingyu

    2016-01-01

    Highlights: • The catalytic combustion of 0.15~3 vol. % low concentration methane in a fluidized bed was studied. • A mathematical model was proposed on the basis of gas–solid flow theory. • A comparative analysis of the established model with plug flow, mixed flow and K-L models was carried out. • The axial methane profile along fluidized bed was predicted by using the mathematical model. • The bed temperature has greater impact on methane conversion than fluidized velocity. - Abstract: This study undertakes a theoretical analysis and an experimental investigation into the characteristics of low-concentration methane catalytic combustion in a bubbling fluidized bed reactor using 0.5 wt.% Pd/Al 2 O 3 as catalytic particles. A mathematical model is established based on gas–solid flow theory and is used to study the effects of bed temperature and fluidized velocity on methane catalytic combustion, and predict the dimensionless methane concentration axial profile in reactor. It is shown that methane conversion increases with bed temperature, but decreases with increasing fluidized velocity. These theoretical results are found to correlate well with the experimental measurement, with a deviation within 5%. A comparative analysis of the developed model with plug flow, mixed flow and K-L models is also carried out, and this further verifies that the established model better reflects the characteristics of low-concentration methane catalytic combustion in a bubbling fluidized bed. Using this reaction model, it was found that the difference in methane conversion between dense and freeboard zones gradually increases with bed temperature; the dense zone reaction levels off at 650 °C, thereby minimizing the difference between the dense and freeboard regions to around 15%. With an increase in bed temperature, the dimensionless methane concentration in the dense zone decreases exponentially, while in the splash zone, it varies from an exponential decay to a

  6. Combustion of gases released from peat or biomass in fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Raiko, R. [Tampere Univ. of Technology (Finland). Energy and Process Engineering

    1996-12-01

    Temperature and gas concentration experiments have been conducted to determine at what temperature carbon monoxide, methane and propane begin to react within the particulate phase of a bubbling fluidized bed. The fluidized bed reactor used in these experiments was a stainless-steel tube with an internal diameter of 50 mm surrounded by an electric heater. Two different natural quartz sands were used (d{sub p} =0.35 mm and 0.6 mm). The bed height used varied between 100 and 260 mm (in unfluidized state). A porous plate distributor, made of kaowool, was used to avoid jets appearing at the distributor. The bed was operated at incipient fluidization (u = 5.9-9 cm/s). The bed temperatures used ranged from 600 deg C to 850 deg C. It was found that carbon monoxide, methane and propane react inside a fluidized bed, but often other conditions than temperature have a considerable effect on the rate of the reaction. The critical temperature was found to be 650 deg C for propane and carbon monoxide and 700 deg C for methane. With under-stoichiometric mixture of carbon monoxide and air the heat release can be over 2.5 MW/m{sup 3} when bed temperature is 650 deg C. According to these experiments it is obvious that the reaction mechanism for carbon monoxide oxidation inside a fluidized bed differs greatly from that of gas phase only. The results of our more than 1300 test runs show clearly the varying effects of the different bed materials. Even with the same bed material totally different results can be obtained. In order to elucidate the possible changes of particle surface, microscopic and porosimetric studies was conducted with both fresh bed particles and used bed particles. Also the effect of commonly used ingredients, like limestone and dolomite, was tested. A global model for carbon monoxide oxidation inside a fluidized bed was introduced. The model was tested against measured data from the laboratory-scale fluidized bed test rig. (Abstract Truncated)

  7. Study of the fluidized bed chemical vapor deposition process on very dense powder for nuclear applications

    International Nuclear Information System (INIS)

    Vanni, Florence

    2015-01-01

    This thesis is part of the development of low-enriched nuclear fuel, for the Materials Test Reactors (MTRs), constituted of uranium-molybdenum particles mixed with an aluminum matrix. Under certain conditions under irradiations, the U(Mo) particles interact with the aluminum matrix, causing unacceptable swelling of the fuel plate. To inhibit this phenomenon, one solution consists in depositing on the surface of the U(Mo) particles, a thin silicon layer to create a barrier effect. This thesis has concerned the study of the fluidized bed chemical vapor deposition (CVD) process to deposit silicon from silane, on the U(Mo) powder, which has an exceptional density of 17,500 kg/m 3 . To achieve this goal, two axes were treated during the thesis: the study and the optimization of the fluidization of a so dense powder, and then those of the silicon deposition process. For the first axis, a series of tests was performed on a surrogate tungsten powder in different columns made of glass and made of steel with internal diameters ranging from 2 to 5 cm, at room temperature and at high temperature (650 C) close to that of the deposits. These experiments helped to identify wall effects phenomena within the fluidized bed, which can lead to heterogeneous deposits or particles agglomeration. Some dimensions of the fluidization columns and operating conditions allowing a satisfactory fluidization of the powder were identified, paving the way for the study of silicon deposition. Several campaigns of deposition experiments on the surrogate powder and then on the U(Mo) powder were carried out in the second axis of the study. The influence of the bed temperature, the inlet molar fraction of silane diluted in argon, and the total gas flow of fluidization, was examined for different diameters of reactor and for various masses of powder. Morphological and structural characterization analyses (SEM, XRD..) revealed a uniform silicon deposition on all the powder and around each particle

  8. Performances of continuous dryer with inert medium fluidized bed

    Directory of Open Access Journals (Sweden)

    Arsenijević Zorana Lj.

    2008-01-01

    Full Text Available A fluid bed dryer with inert particles represents a very attractive alternative to other drying technologies according to the main efficiency criteria, i.e. specific water evaporation rate, specific heat consumption and speci­fic air consumption. A high drying efficiency results from the large con­tact area and from the large temperature difference between the inlet and outlet air. A rapid mixing of the particles leads to nearly isothermal conditions throughout the bed. A fluid bed dryer with inert particles was used for drying of slurries. Experiments were performed in a cylindrical column 215 mm in diameter with glass spheres as inert particles. In this paper, results of drying experi­ments with slurries of Zineb fungicide, copper hydroxide, calcium carbo­nate and pure water used as the feed material are presented. In our fluidized bed we successfully dried a number of other materials such as: fungicides and pesticides (Ziram, Propineb, Mangozeb, copper oxy-chloride, copper oxy-sulphate, Bordeaux mixture, other inorganic compounds (calcium sulphate, cobalt carbonate, electrolytic copper, sodium chloride, and a complex compound (organo-bentonite. The effects of operating conditions on dryer throughput and product quality were investigated. Main performance criteria, i.e. specific water evaporation rate, specific heat consumption and specific air consumption, were quantified. Temperature profile along the bed was mapped, and nearly isothermal conditions were found due to thorough mixing of the particles. Analysis of drying and energy efficiencies as a function of inlet and outlet air temperature difference was performed for deeper insight in dryer behavior and for optimizing dryer design and operation from an energy point of view. A simple mathematical model based on an overall heat balance predicts the dryer performance quite well. The industrial prototype with fluid bed of 0.8 m in diameter and capacity 650 kg of evaporated moisture per

  9. Characterization of biofilm in 200W fluidized bed reactors

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Michelle H. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Saurey, Sabrina D. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Lee, Brady D. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Parker, Kent E. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Eisenhauer, Emalee E. R. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Cordova, Elsa A. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Golovich, Elizabeth C. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)

    2014-09-29

    Contaminated groundwater beneath the 200 West Area at the Hanford Site in Southeast Washington is currently being treated using a pump and treat system to remove organics, inorganics, radionuclides, and metals. A granular activated carbon-based fluidized bed reactor (FBR) has been added to remove nitrate, hexavalent chromium and carbon tetrachloride. Initial analytical results indicated the microorganisms effectively reduced many of the contaminants to less than cleanup levels. However shortly thereafter operational upsets of the FBR include carbon carry over, over production of microbial extracellular polymeric substance (biofilm) materials, and over production of hydrogen sulfide. As a result detailed investigations were undertaken to understand the functional diversity and activity of the microbial community present in the FBR over time. Molecular analyses including terminal restriction fragment length polymorphism analysis, quantitative polymerase chain reaction and fluorescent in situ hybridization analyses were performed on the microbial community extracted from the biofilm within the bed and from the inoculum, to determine functional dynamics of the FBR bed over time and following operational changes. Findings from these analyses indicated: 1) the microbial community within the bed was completely different than community used for inoculation, and was likely from the groundwater; 2) analyses early in the testing showed an FBR community dominated by a few Curvibacter and Flavobacterium species; 3) the final sample taken indicated that the microbial community in the FBR bed had become more diverse; and 4) qPCR analyses indicated that bacteria involved in nitrogen cycling, including denitrifiers and anaerobic ammonia oxidizing bacteria, were dominant in the bed. These results indicate that molecular tools can be powerful for determining functional diversity within FBR type reactors. Coupled with micronutrient, influent and effluent chemistry

  10. Evidence for Quaternary earthquakes from paleo-fluidization structures along the Pernambuco lineament (NE-Brazil).

    Science.gov (United States)

    Nestola, Yago; Balsamo, Fabrizio; Hilario Rego Bezerra, Francisco; Cézar Costa Nogueira, Fancisco; Storti, Fabrizio

    2014-05-01

    Plate tectonics theory postulate that seismicity is mostly restricted to the plate's boundaries. Nevertheless, intraplate earthquakes occur in stable continental areas such as the NE-Brazilian craton, where seismicity is clustered along fault systems reactivating major Neoproterozoic shear zones. Moreover, evidence for tectonic activity is recorded in the Cenozoic post-rift formations, widely outcropping along the coast of the NE-Brazilian passive margin. To investigate such unexpected seismic and tectonic activity we performed a structural field survey along the coastal segment of the Pernambuco shear zone, where the Miocene sandstone of the Barreiras Fm. and the overlying Quaternary post-Barreiras deposits extensively crop out. They are separated by a Tortonian lateritic paleosoil and are affected by mainly extensional faulting, associated with some strike-slip deformation, clustered in N-S, WNW-ESE, and NE-SW trends. In the proximity of the Pernambuco shear zone, in the hinterland of the Recife town, we found evidence for paleo-fluidization structures in post-Barreiras deposits, where mobilized materials include cm-dm-sized, heterogeneous angular clasts in a sandy-dominated matrix. The extent of the exposed fluidized bodies exceeds ~50 m in active quarry walls, the maximum thickness reaches ~3 m, and the depth of fluidization is estimated to be about 30 m. The top seal of fluidized material was provided by a ~80 cm thick clay layer. Such fluidizations are located few hundreds meters far from a major NE-SW-trending, sin-sedimentary extensional fault zone developed in Quaternary deposits, which is consistent with a left-lateral strike-slip sense of shear of the Pernambuco shear zone. Our results further improve the knowledge of paleo-seismic activity along the Pernambuco shear zone and, in particular, provide additional information for the seismic hazard assessment in the high-density populated area of the Recife town.

  11. A Coarse-Grained Two-Fluid Model for Gas-Solid Fluidized Beds

    Directory of Open Access Journals (Sweden)

    S. Schneiderbauer

    2014-03-01

    Full Text Available Due to increasing computer power the numerical simulation of fluidized and moving beds has become feasible. However, while kinetic theory based CFD (Computational Fluid Dynamics has become a valuable design tool for modeling pilot plant scale gassolid fluidized bed reactors, a fully resolved simulation of industrial scale reactor is still nearly unfeasible. It is, therefore, common to use sub-grid models to account for the effect of the small unresolved structures on large resolved scales when using coarse grids. It is generally agreed that the influence of these small scales on the drag force is a key parameter in the prediction of the hydrodynamics of fluidized beds. We present a sub-grid drag modification dealing with the influence of heterogeneous structures on the drag force. It is assumed that these structures appear as distinct clusters of particles within an interstitial dilute particle phase. The clusters and the dilute phase itself consist of homogeneously distributed particles enabling the application of a homogenous drag correlation to these structures. In contrast to the established sub-grid drag modification EMMS (Energy-Minimization Multi-Scale Method, the presented model distinguishes between resolved and unresolved clusters by computing the expectation value of the diameter of the unresolved clusters. This reveals a grid and slip velocity dependent drag modification, which recovers the homogenous drag law as the solids volume fraction approaches the maximum packing of frictional spheres. The presented model is validated on the one hand, in case of industrial scale bubbling and turbulent fluidized beds. On the other hand, the model is applied to the coarse grid simulation of a riser flow. The numerical results obtained on a coarse gird demonstrate that our model reveals fairly good agreement with experimental data of bed expansion and solids volume fraction distributions. Thus, the results proof that the presented drag

  12. A New Fluidized Bed Bioreactor Based on Diversion-Type Microcapsule Suspension for Bioartificial Liver Systems.

    Directory of Open Access Journals (Sweden)

    Juan Lu

    Full Text Available A fluidized bed bioreactor containing encapsulated hepatocytes may be a valuable alternative to a hollow fiber bioreactor for achieving the improved mass transfer and scale-up potential necessary for clinical use. However, a conventional fluidized bed bioreactor (FBB operating under high perfusion velocity is incapable of providing the desired performance due to the resulting damage to cell-containing microcapsules and large void volume. In this study, we developed a novel diversion-type microcapsule-suspension fluidized bed bioreactor (DMFBB. The void volume in the bioreactor and stability of alginate/chitosan microcapsules were investigated under different flow rates. Cell viability, synthesis and metabolism functions, and expression of metabolizing enzymes at transcriptional levels in an encapsulated hepatocyte line (C3A cells were determined. The void volume was significantly less in the novel bioreactor than in the conventional FBB. In addition, the microcapsules were less damaged in the DMFBB during the fluidization process as reflected by the results for microcapsule retention rates, swelling, and breakage. Encapsulated C3A cells exhibited greater viability and CYP1A2 and CYP3A4 activity in the DMFBB than in the FBB, although the increases in albumin and urea synthesis were less prominent. The transcription levels of several CYP450-related genes and an albumin-related gene were dramatically greater in cells in the DMFBB than in those in the FBB. Taken together, our results suggest that the DMFBB is a promising alternative for the design of a bioartificial liver system based on a fluidized bed bioreactor with encapsulated hepatocytes for treating patients with acute hepatic failure or other severe liver diseases.

  13. Hydrodynamic studies of the flow of fine particles through a fluidized dense bed of coarse solids

    Energy Technology Data Exchange (ETDEWEB)

    Talukdar, J.

    1993-12-31

    This study explains the hydrodynamics of a circulating fluidized bed (CFB) system, the Battelle Multi-Solids Fluidized Bed System (MSFB). It consists of a circulating fluidized bed of fine particles superimposed on a bubbling bed of coarse solids. One way to characterize such a system is to describe the mechanism of gas-solid flow through the bed. The gas flow in systems like these is through bubbles or slugs (regions of voids containing little or no solids). Bubbles are typically characterized by their size (length or diameter), their rise velocity, and their frequency. Another task of the initial phase of this study is to characterize an L-valve, a solids-recirculating device commonly used in an MSFB. Next, the mechanism of fine particle movement through a bubbling region of coarse fluidized solids is studied in considerable detail. Bubble characteristics are studied in a variety of systems of coarse particles with fines passing through at high velocity. Amongst numerous optical, electrical and other techniques available for the study of the passage of bubbles, the pressure fluctuation technique is the most robust. In this investigation, pressure probes are connected to pressure transducers which are in turn linked to an on-line data acquisition system supported on a microcomputer. A commercially available software package (Notebook) is used to sample pressure at specified points in the fluidized bed at extremely fast rates, of up to 200 Hz. This resulted in pressure-time traces which are analysed to give bubble length, bubble rise velocity, and bubble frequency. Another important objective of this study is to estimate the fine particle residence time in the dense bed section. A defluidization technique is utilized in experimentally measuring the solids holdup in the dense bed. A mathematical model is developed from first principles, based on a momentum balance on the fine particles.

  14. Hydrodynamic study of the turbulent fluidized beds; Etude hydrodynamique des lits fluidises turbulents

    Energy Technology Data Exchange (ETDEWEB)

    Taxil, I.

    1996-12-20

    Gas-solid turbulent fluidization has already been widely studied in the literature. However, its definition and specificities remain controversial and confused. Most of the studies focussed on the turbulent transition velocities are based on wall pressure drop fluctuations studies. In this work, we first characterize the turbulent regime with the classical study of pressure drop signals with standard deviation analysis, completed with a more specific frequency analysis and also by a stochastic analysis. Then, we evaluate bubble flow properties. Experimental results have been obtained in a 0.2 m I.D. fluidized bed expanding to 0.4 m I.D. in the freeboard in order to limit entrainment at high fluidization velocities. The so lid used was FCC catalyst. It was fluidized by air at ambient conditions. The superficial fluidization velocity ranged 0.2 to 2 m/s. Fast response transducers recorded pressure drop at the wall and bubble flow properties (bubble size, bubble velocity and bubble frequency) could be deduced from a light reflected signal at various bed locations with optical fibers. It has been shown the turbulent regime is delimited by two velocities: Uc (onset of turbulent regime) and Utr (onset of transport regime), which can be determined based on standard deviations, dominant frequencies and width of wave land of pressure signals. The stochastic analysis confirms that the signal enriches in frequencies in the turbulent regime. Bubble size and bubble velocity could be correlated to the main superficial gas velocity. The main change in bubble flow in the turbulent regime was shown to be the stagnation of the bubble frequency at its maximum value. It was also shown that the bubble flow properties in the turbulent regime imply a strong aeration of the emulsion phase. (authors) 76 refs.

  15. Ecological characteristics of the fluidized bed boilers burning low-rank lignite coal

    International Nuclear Information System (INIS)

    Fett, F.N.; Heinbockel, I.; Dersch, J.

    1996-01-01

    The performance simulation of fluidized bed coal plants with Bulgarian low-rank coal has been made. Fluidized bed models, developed in the Institute of Energy Technology, UGN - Siegen, based on one-dimensional compartment-in-series model have been used. The parameters of each data block can be optimized according to criteria chosen in advance. The 'quality of coal - pollution characteristics of the boilers' channel has been chosen as a channel of priority importance. The input information on coal quality characteristics reflects the regression connections between ash content and the other quality components. The wide range of ash value variations of the coal (26 - 44%) causes a lot of problems. Two different models - Atmospheric Bubbling Fluidized Bed Model (ABFB) and Atmospheric Circulated Fluidized Bed Model - have been applied. Some results of computer experiments with ABFB model are given presenting the influence of coal quality on temperature profile in the combustor and on ecological characteristics of the gases. The following interconnections are marked: 1) ash content increase (connected with a net calorific value diminution) leading to a decrease in the temperature along the height of the furnace; 2) dependence of SO 2 concentration on the ash value connected with the 'temperature - NO x ' relationship; 3) decrease in SO 2 concentration caused by the augmentation of Ca/S ratio and the increase in the ash content of the coal. It is concluded that the fluidized bed technology is reliable enough for the Bulgarian low rank lignite because of the low rate of the environmental pollutants. 4 figs., 3 refs

  16. End uses of electric energy in homes of a group of dwellings; Usos finales de la energia electrica en hogares de un conjunto habitacional

    Energy Technology Data Exchange (ETDEWEB)

    Campero Littlewood, E.; Romero Cortes, J.; Alarcon Maldonado, E.; Silva Oliver, J.; Ortiz Segura, J.; Vargas Rubio, J. [Departamento de Energia, Universidad Autonoma Metropolitana - Unidad Azcapotzalco, Mexico, D. F. (Mexico)

    1997-12-31

    ). El analisis de la informacion permite conocer la capacidad de consumo de energia electrica que tienen las viviendas de la muestra y a hacer inferencias de la capacidad de consumo de la unidad habitacional.

  17. Centro de Investigaciones Nucleares Aplicadas a la Agricultura (CINAGRI). Venezuela. Final report of the projects VEN/86/007 and VEN/5/009

    International Nuclear Information System (INIS)

    Gil, J.L.

    1992-01-01

    The summary of the technical activities carried out on the project ''Centro de Investigaciones Nucleares Aplicadas a la Agricultura'' (CINAGRI) is presented. The objectives of this project are to establish nuclear and biotechnology techniques, practices with a view to increasing agriculture and live-stock productivity, and to transfer this technology to farmers

  18. Near-infrared spectroscopy monitoring and control of the fluidized bed granulation and coating processes-A review.

    Science.gov (United States)

    Liu, Ronghua; Li, Lian; Yin, Wenping; Xu, Dongbo; Zang, Hengchang

    2017-09-15

    The fluidized bed granulation and pellets coating technologies are widely used in pharmaceutical industry, because the particles made in a fluidized bed have good flowability, compressibility, and the coating thickness of pellets are homogeneous. With the popularization of process analytical technology (PAT), real-time analysis for critical quality attributes (CQA) was getting more attention. Near-infrared (NIR) spectroscopy, as a PAT tool, could realize the real-time monitoring and control during the granulating and coating processes, which could optimize the manufacturing processes. This article reviewed the application of NIR spectroscopy in CQA (moisture content, particle size and tablet/pellet thickness) monitoring during fluidized bed granulation and coating processes. Through this review, we would like to provide references for realizing automated control and intelligent production in fluidized bed granulation and pellets coating of pharmaceutical industry. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. State of the art and the future fuel portfolio of fluidized bed combustion systems; Status und kuenftiges Brennstoffportfolio bei Wirbelschichtfeuerungen

    Energy Technology Data Exchange (ETDEWEB)

    Szentannai, Pal; Friebert, Arpad; Winter, Franz [Technische Univ. Wien (Austria). Inst. fuer Verfahrens-, Umwelttechnik und technische Biowissenschaften

    2008-07-01

    Coal, biomass and substitute fuels energetically can be used efficiently and with low pollution in fluidized bed plants. In comparison to biomass there are significant differences between the circulating and stationary fluidized bed technology. The stationary fluidised bed is fed predominantly with biomasses and residual substances. Coal usually is the basis fuel in the circulating fluidised bed. Biomass and residual substances frequently are course-fired. The state of the art is the employment of a broad fuel mixture in small and large fluidized-bed combustion systems. Future developments present an increased use of sewage sludge, fluidized bed combustion systems with wood as a basis fuel, utilization of household waste and the gas production.

  20. An experimental study of heat transfer to a horizontal tube in a large particle fluidized bed at elevated temperature

    Science.gov (United States)

    George, A. H.

    Experimental data for the time-average local heat transfer coefficient to a single horizontal tube in a large particle fluidized bed at elevated temperature, are presented. Refractory particles with surface mean diameter 2.14 mm and 3.23 mm were fluidized by combustion products of propane at bed temperatures of 810 K and 1053 K. The particle sizes are near the largest presently used in pilot plant fluidized bed coal combustors. The superficial gas velocity ranged from that required for minimum fluidization, or slightly packed, to the velocity where slugging first occurred, or the highest velocity air blower capacity would allow. Heat transfer results indicate that a stack of defluidized particles remain on top of the tube at low superficial gas velocities. A very low local heat transfer coefficient was obtained under these conditions. There was less than 10 percent difference in the maximum spatial average heat transfer coefficients for the two particle sizes considered.

  1. Development of thin PdeAg supported membranes for fluidized bed membrane reactors including WGS related gases

    OpenAIRE

    Fernandez, E Ekain; Helmi Siasi Farimani, A Arash; Coenen, KT Kai; Meléndez, J; Viviente, JL; Pacheco Tanaka, DA; Sint Annaland, van, M Martin; Gallucci, F Fausto

    2015-01-01

    This paper reports the preparation, characterization and stability tests of Pd-based thin membranes for fluidized bed membrane reactor applications. Various thin membranes have been prepared by simultaneous Pd-Ag electroless plating. A simple technique for sealing of the produced membranes is reported and discussed. The membranes have been characterized for single gas permeation, and afterwards used for permeation of mixtures of gases and under fluidization conditions. The membranes have show...

  2. Hybrid system of generating electricity, solar eolic diesel San Juanico, Baja California Sur, Mexico; Sistema hibrido de generacion electrica, eolico solar diesel San Juanico, Baja California Sur, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Huerta, Javier [Comision Federal de Electricidad, La Paz, Baja California Sur (Mexico); Johnston, Peter [Technology Development, Arizona (United States); Napikoski, Chester [Generation Engineering, Arizona (United States); Escutia, Ricardo [Comision Federal de Electricidad, Baja California Sur (Mexico)

    2000-07-01

    that is generated thru the selling of electric energy, guarantees the sustainable operation of the system. [Spanish] La Comision Federal de Electricidad (CFE), y la empresa electrica norteamericana Arizona Public Service (APS), firmaron un convenio de colaboracion para desarrollar un proyecto de generacion de energia electrica con la utilizacion de energias renovables. Las premisas que se acordaron fueron las siguientes: 1. Enfoque del proyecto hacia una comunidad rural. 2. El costo de la obra debera ser menor al de su interconexion con el sistema convencional. 3. Aceptacion por parte de la comunidad, y autoridades gubernamentales. 4. Sustentabilidad de la operacion del sistema. Se efectuaron diversos analisis tecnicos y economicos asi como la evaluacion del recurso solar y eolico, estudio de impacto ambiental, plan de negocios para obtener la aprobacion de los recursos economicos ante instancias como Niagara Mohawk (NIMO), y la USAID, mediante la supervision de los Laboratorios Nacionales de Sandia. Despues de efectuarse las mediciones anemometricas y de radiacion solar, en diversas comunidades, se considero a la comunidad de San Juanico como la mas viable; tambien los aspectos de logistica, sociales, tamano de la comunidad y como detonador para las actividades economicas como la pesca y el turismo. La APS llevo a cabo el proyecto ejecutivo de conformidad con las recomendaciones de la Comision Federal de Electricidad. El proyecto consistio basicamente en la instalacion de 10 aerogeneradores de 10 Kw. c/u, un arreglo solar de 17 Kw., un inversor de 70 Kw., un banco de baterias de 432 Kwh., mas un motogenerador diesel de emergencia de 80 Kw. Ademas de la obra civil y electromecanica. Fue necesario involucrar a la poblacion en el conocimiento y seguimiento del proyecto desde sus inicios, ya que consideramos que este factor seria indispensable para lograr el exito del mismo. Se instalaron lamparas ahorradoras de energia en viviendas y alumbrado publico para optimizar el

  3. FLUIDIZED BED STEAM REFORMER (FBSR) PRODUCT: MONOLITH FORMATION AND CHARACTERIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Jantzen, C

    2006-09-13

    The most important requirement for Hanford's low activity waste (LAW) form for shallow land disposal is the chemical durability of the product. A secondary, but still essential specification, is the compressive strength of the material with regards to the strength of the material under shallow land disposal conditions, e.g. the weight of soil overburden and potential intrusion by future generations, because the term ''near-surface disposal'' indicates disposal in the uppermost portion, or approximately the top 30 meters, of the earth's surface. The THOR{reg_sign} Treatment Technologies (TTT) mineral waste form for LAW is granular in nature because it is formed by Fluidized Bed Steam Reforming (FBSR). As a granular product it has been shown to be as durable as Hanford's LAW glass during testing with ASTM C-1285-02 known as the Product Consistency Test (PCT) and with the Single Pass Flow Through Test (SPFT). Hanford Envelope A and Envelope C simulants both performed well during PCT and SPFT testing and during subsequent performance assessment modeling. This is partially due to the high aluminosilicate content of the mineral product which provides a natural aluminosilicate buffering mechanism that inhibits leaching and is known to occur in naturally occurring aluminosilicate mineral analogs. In order for the TTT Na-Al-Si (NAS) granular mineral product to meet the compressive strength requirements (ASTM C39) for a Hanford waste form, the granular product needs to be made into a monolith or disposed of in High Integrity Containers (HIC's). Additionally, the Hanford intruder scenario for disposal in the Immobilized Low Activity Waste (ILAW) trench is mitigated as there is reduced intruder exposure when a waste form is in a monolithic form. During the preliminary testing of a monolith binder for TTT's FBSR mineral product, four parameters were monitored: (1) waste loading (not optimized for each waste form tested); (2) density

  4. The Influence of the Distributor Plate on the Bottom Zone of a Fluidized Bed Approaching the Transition from Bubbling to Turbulent Fluidization

    OpenAIRE

    Paiva, J. M.; Pinho, C.; Figueiredo, R.

    2004-01-01

    The dynamics of the bottom zone of a narrow fluidized bed, from bubbling to turbulent regimes, was studied in a cold model of 0.1 m i.d. and 1.3 m high. Tested distributor types were perforated perspex plates, with six different perforation grids, metallic mesh and porous ceramic, with pressures drops ranging from 0.05 to 350 kPa, corresponding to superficial air velocities from 0.1 to 2.3m s-1. Group B silica ballotini, within the range 0.355-0.425 mm, were used as bed material. The experime...

  5. Proceedings of the sixth international conference on fluidized bed combustion. Volume II. Technical sessions

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-08-01

    The Sixth International Conference on Fluidized Bed Combustion was held April 9-11, 1980, at the Atlanta Hilton, Atlanta, Georgia. It was sponsored by the US Department of Energy, the Electric Power Research Institute, the US Environmental Protection Agency, and the Tennessee Valley Authority. The papers covered recent developments in atmospheric and pressurized fluidized-bed combustion, especially the design, operation and control of pilot and demonstration plants. The cleanup of combustion products and the erosion, corrosion and fouling of gas turbines was emphasized also. Fifty-five papers from Volume 2 of the proceedings have been entered individually into EDB and ERA; five papers had been entered previously from other sources. (LTN)

  6. Modeling of cleaning of dust emission’ in fluidized bed building aspiration’ collector

    Directory of Open Access Journals (Sweden)

    Koshkarev Sergey A.

    2017-01-01

    Full Text Available This article describes one of the modern way to reduce dust emissions of pollutions exhausting into the atmosphere at expanded clay aggregates and other similar building materials manufactures applying filtering fluidized granular particulate material bed’ separator with low degree of dust leakage out from one. There is presented quasi-diffusion model featuring of process of cleaning of industrial emissions of dust in devices of tray type with the fluidized and weighted bed. There considered case of variable coefficient of longitudinal hashing intermixing within trough tray type separator in this article. It was made attempt to get meanings value of leakage’ degree dust out from separator. It was obtain in an implicit form. It was obtained and announced some results of the carried-out analysis are intended to get high efficiency of dust removal set up installations to clean emissions of aspiration scheme of the air environmental protection in production of bulk dispersed materials building construction industry.

  7. Exploring the significance of the fluidized flow regime for avalanche hazard mapping

    Science.gov (United States)

    Issler, Dieter; Gauer, Peter

    Observational and experimental evidence suggests that it is important to explicitly account for the fluidized flow regime in avalanche hazard mapping due to its high mobility, intermediate density and high velocity. We explore the differences from conventional runout modelling by implementing an extension of the Norem-Irgens-Schieldrop (NIS) rheology in a simple mass-point model. When the dispersive stresses and the excess pore pressure equal the overburden pressure, the flow height increases and the density diminishes until a new equilibrium is reached, determined by the different density dependencies of the two parameters of the dispersive stresses. Fluidization requires sufficiently steep terrain; when it occurs it leads to substantially higher velocities than compared to the dense-flow regime. The model parameters are strongly constrained by their physical meaning and vary little between widely different avalanches. However, in all test cases we obtained better agreement between simulated and observed runout distances and pressure effects than with conventional models.

  8. Using deepest regression method for optimization of fluidized bed granulation on semi-full scale.

    Science.gov (United States)

    Rambali, B; Van Aelst, S; Baert, L; Massart, D L

    2003-06-04

    This study applied the deepest regression method to estimate the granule size of unsuccessful fluidized bed granulation runs. This study uses data from a previous study [Int. J. Pharm. 220 (2001) 149] on optimization of fluidized granulation process, wherein 8 of the 30 runs did not succeeded due to overwetting of the powder bed. The "complete data" (the observed and the estimated granule size by the depth regression method) were used to develop two regression models for the granule size: an empirical model based on the process variables (inlet air temperature, inlet airflow rate, spray rate, and inlet air humidity) and a fundamental model based on the powder bed moisture content and the relative droplet size. The regression models based on the incomplete data from the previous study and the regression models of the "complete data" were comparable in the sense that the contour plots based on the respective models and the predicted granule size were comparable.

  9. Determination of fluidized bed granulation end point using near-infrared spectroscopy and phenomenological analysis.

    Science.gov (United States)

    Findlay, W Paul; Peck, Garnet R; Morris, Kenneth R

    2005-03-01

    Simultaneous real-time monitoring of particle size and moisture content by near-infrared spectroscopy through a window into the bed of a fluidized bed granulator is used to determine the granulation end point. The moisture content and particle size determined by the near-infrared monitor correlates well with off-line moisture content and particle size measurements. The measured particle size is modeled using a population balance approach, and the moisture content is shown to follow accepted models during drying. Given a known formulation, with predefined parameters for peak moisture content, final moisture content, and final granule size, the near-infrared monitoring system can be used to control a fluidized bed granulation by determining when binder addition should be stopped and when drying of the granules is complete. Copyright 2005 Wiley-Liss, Inc. and the American Pharmacists Association.

  10. Modeling Fluid Dynamics and Growth Kinetics in Fluidized Bed Spray Granulation

    Directory of Open Access Journals (Sweden)

    Zhen Li

    2010-12-01

    Full Text Available Fluidized bed spray granulation is used to produce spherical granules from suspensions, solutions and melts. Experimental investigations revealed that fluid dynamics in the granulator plays a crucial role, in particular in the jet. The jet causes the particle movement as well as drop propagation and deposition on the particles. In this work the “Two Fluid Model” (TFM is used to simulate the multiphase fluid dynamics in the fluidized bed. The results of simulations were validated by measuring the particle velocity using Laser Doppler Velocimetry (LDV. From the TFM-simulations with implemented growth mechanisms the growth kinetics is obtained and is used to describe the transient states of various granulation processes by solving the appropriate population balances.

  11. Generation of hydrogen rich gas through fluidized bed gasification of biomass.

    Science.gov (United States)

    Karmakar, M K; Datta, A B

    2011-01-01

    The objective of this study was to investigate the process of generating hydrogen rich syngas through thermo chemical fluidized bed gasification of biomass. The experiments were performed in a laboratory scale externally heated biomass gasifier. Rice husk had been taken as a representative biomass and, steam had been used as the fluidizing and gasifying media. A thermodynamic equilibrium model was used to predict the gasification process. The work included the parametric study of process parameters such as reactor temperature and steam biomass ratio which generally influence the percentage of hydrogen content in the product gas. Steam had been used here to generate nitrogen free product gas and also to increase the hydrogen concentration in syngas with a medium range heating value of around 12 MJ/Nm3. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. The effect of vibration on bed voidage behaviors in fluidized beds with large particles

    Directory of Open Access Journals (Sweden)

    H. Jin

    2007-09-01

    Full Text Available The effects of vibration parameters, operating conditions and material properties on bed voidage were investigated using an optical fiber probe approach in a vibrating fluidized bed with a diameter of 148 mm. Variables studied included frequency (0-282 s-1, amplitude (0 mm-1 mm, bed height (0.1 m-0.4 m as well as four kinds of particles (belonging to Geldart's B and D groups. The axial and radial voidage distribution with vibration is compared with that without vibration, which shows vibration can aid in the fluidization behaviors of particles. For a larger vibration amplitude, the vibration seriously affects bed voidage. The vibration energy can damp out for particle layers with increasing the bed height. According to analysis of experimental data, an empirical correlation for predicting bed voidage, giving good agreement with the experimental data and a deviation within ±15%, was proposed.

  13. Operating experience and development of fluidized-bed denitrators for UNH at Tokai Reprocessing Plant

    International Nuclear Information System (INIS)

    Sasaki, Minoru; Nakamichi, Hideya; Takeda, Seiichiro; Kubota, Kanya; Katoh, Shuji

    1983-01-01

    The fluidized bed denitrator for uranyl nitrate hexahydrate (UNH) at Tokai reprocessing plant has been operated since 1976. About 170 tons of spent fuel have been reprocessed, and the denitrator has encountered numerous operational problems during the period. This report deals with these technical problems and the associated countermeasures taken, including the dismantling and reconstruction of equipment and the improvement of operating method. The major problems encountered were as follows: (1) the crystallization of UNH on the UNH feeding line, (2) spray nozzle clogging and candle filter clogging, (3) particle growth, (4) plugging of the drawing-out line by nozzle caking, and (5) slugging in fluidized-bed denitration. The total quantity and quality of UO 3 products obtained so far at the plant are also briefly described together with some future R and D programs such as the improvement of UO 3 reactivity and the automation of denitrators. (Aoki, K.)

  14. Ash and heavy metals in fluidized bed-combustion; Tuhka ja raskasmetallit puuperaeisen jaetteen kerrosleijupoltossa

    Energy Technology Data Exchange (ETDEWEB)

    Kaessi, T.; Aittoniemi, P. [IVO International, Vantaa (Finland)

    1996-12-01

    Combustion ashes and submicron fly ash particles were characterized in two industrial boilers (bubbling vs. circulating fluidized bed) burning paper mill deinking sludge and bark or wood as support fuel. Bulk samples from fly ash, circulating ash and bottom ash were analyzed. Fine particles in fly ash were monitored and sampled for microscopic studies. The mass size distribution of fly ash was measured and the chemical composition according to particle size was analyzed. The results showed that ash consists of large and friable clusters formed by sintering of small mineral particles originating from paper fillers. Very few ash particles were fused and they were found only among the smallest particles. No agglomerates of fused particles were found. If the residence time in furnace is long enough sintering may proceed further and ash structure grows more dense. No indication of ash vaporization was detected. These results were similar for bubbling and circulating fluidized bed boilers. (author)

  15. Energy extraction from wine dregs by self-sustained burning with fluidized-bed combustor

    Energy Technology Data Exchange (ETDEWEB)

    Leu, J.H. [Yu-Da Inst. of Business Technology, Taiwan (China). Dept. of Marketing and Logistics Management; Chung, Y.N.; Pan, T.S.; Chen, C.S. [Dayeh Univ., Taiwan (China). Dept. of Electrical Engineering

    2005-07-01

    Wine dregs typically have moisture contents of between 70 and 80 per cent, and the disposal of wine dregs in Taiwan is both costly and time-consuming. This paper described a method of extracting energy from wine dregs through the use of a pre-drying technique with a fluidized bed technology. A bubble-type fluidized bed combustor was used to combust high moisture Chinese Kaoliang wine lees. The system consisted of an incinerator, a feeding system, a heat recovery system, and an air pollution control system. Results of the experimental study showed that 92.3 per cent combustion was achieved for the wine lees at temperatures of 860 degrees C. Sulfur oxide (SO{sub x}) emissions and nitrogen oxide (NO{sub x}) emissions were negligible. Carbon monoxide (CO) emissions were suppressed to 92 ppm by modulating operating temperatures, axial temperature distributions, and primary and excess air. 3 refs., 3 tabs., 7 figs.

  16. Recovery and separation of iron from iron ore using innovative fluidized magnetization roasting and magnetic separation

    Directory of Open Access Journals (Sweden)

    Yu J.

    2018-01-01

    Full Text Available In this investigation, a pilot-scale fluidized magnetization roasting reactor was introduced and used to enhance magnetic properties of iron ore. Consequently, the effects of roasting temperature, reducing gas CO flow rate, and fluidizing gas N2 flow rate on the magnetization roasting performance were studied. The results indicated that the hematite was almost completely converted into magnetite by a gas mixture of 4 Nm3/h CO and 1 Nm3/h N2 at roasting temperature of 540°C for about 30 s. Under optimized conditions, a high grade concentrate containing 66.84% iron with iron recovery of 91.16% was achieved. The XRD, VSM, and optical microscopy (OM analyses revealed that most of the hematite, except some coarse grains, was selectively converted to magnetite, and that the magnetic properties were greatly enhanced. Thus, their separation from non-magnetic gangue minerals was facilitated.

  17. Beckmann rearrangement of cyclohexanone oxime to {epsilon}-caprolactam using a fluidized bed reactor

    Energy Technology Data Exchange (ETDEWEB)

    Dahlhoff, G.; Hoelderich, W.F. [Technische Hochschule Aachen (Germany)

    1999-07-01

    The application of a fluidized bed reactor on the heterogeneously catalyzed Beckmann rearrangement of cyclohexanone oxime to {epsilon}-caprolactam is presented. For this purpose the classic industrial synthesis route is compared to the new route catalyzed by [B]-MFI zeolite which proved to be the most suitable. To prepare the use of the catalyst the thermodynamics were calculated showing that the residence time of the reactants are of great importance. A regeneration model was developed resulting in a mathematical equation for the regeneration time calculated to seven hours under oxidative conditions. A 40 day regeneration experiment demonstrated the excellent regeneration behaviour of the chosen catalyst showing no decrease in activity after 40 recycle treatments. Finally, the experiments in a constructed non circulating fluidized bed showed good yields and selectivities (99%/91%) completely comparable to the actual synthesis route but avoiding 4 t ammonia sulphate/t product. (orig.)

  18. Mechanistic modelling of fluidized bed drying processes of wet porous granules

    DEFF Research Database (Denmark)

    Mortier, Séverine Thérèse F.C.; De Beer, Thomas; Gernaey, Krist

    2011-01-01

    granules is given. This review provides a basis for future mechanistic model development for the drying process of wet granules in pharmaceutical processes. It is intended for a broad audience with a varying level of knowledge on pharmaceutical processes and mathematical modelling. Mathematical models...... particle, can be described using the continuum approach, the pore network modelling method and the shrinkage of the diameter of the wet core approach. As several granules dry at a drying rate dependent on the gas temperature, gas velocity, porosity, etc., the moisture content of a batch of granules......Fluidized bed dryers are frequently used in industrial applications and also in the pharmaceutical industry. The general incentives to develop mechanistic models for pharmaceutical processes are listed, and our vision on how this can particularly be done for fluidized bed drying processes of wet...

  19. A nonlinear model for the fluidization of marine mud by waves

    Energy Technology Data Exchange (ETDEWEB)

    Foda, M.A.; Hunt, J.R.; Chou, Hsien-Ter (Univ. of California, Berkeley (United States))

    1993-04-15

    The authors consider the problem of fluidization of mud deposits in shallow waters due to interactions with water waves. This is of increasing interest because of concerns that water pollutants, including heavy metals, pesticides, etc., are often found near surfaces of mud deposits. The authors look at the question of whether the cohesive properties of mud deposits exhibit nonlinear properties when they experience strains from water wave interactions. It is obvious that with large enough wave interactions the deposits become fluidized, and are not in that case truly nonlinear. In their modeling efforts they try to incorporate these ideas into a cohesive model where the magnitude of the water wave-sediment interaction has an influence on the type of response within the system.

  20. SPECIFIC FEATURES OF THE OXYFUEL COMBUSTION CONDITIONS IN A BUBBLING FLUIDIZED BED

    Directory of Open Access Journals (Sweden)

    Pavel Skopec

    2016-08-01

    Full Text Available Oxyfuel combustion is a promising approach for capturing CO2 from power plants. This technology produces a flue gas with a high concentration of CO2. Our paper presents a verification of the oxyfuel combustion conditions in a bubbling fluidized bed combustor. It presents a theoretical analysis of oxyfuel combustion and makes a comparison with combustion using air. It is important to establish a proper methodology for stoichiometric calculations and for computing the basic characteristic fluidization properties. The methodology presented here has been developed for general purposes, and can be applied to calculations for combustion with air and with oxygen-enriched air, and also for full oxyfuel conditions. With this methodology, we can include any water vapour condensation during recirculation of the flue gas when dry flue gas recirculation is used. The paper contains calculations for a lignite coal, which is taken as a reference fuel for future research and for the experiments.