WorldWideScience

Sample records for intravenous digital subtraction

  1. Exercise intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Yiannikas, J.

    1986-01-01

    Attempts to use exercise ventriculography have been made, not only to give diagnostic and perhaps even prognostic information in patients with coronary artery disease, but also in patients with valvular heart disease both before and after surgical intervention. Clearly an accurate method of assessing ventricular function under conditions of stress in various cardiac diseases would provide important information that would help in patient management. Exercise ventriculography using gated blood pool equilibrium technetium studies are widely used, but are limited by spatial resolution and by the foreshortening affects of visualizing the left ventricular chamber in the left anterior oblique view. First pass radionuclide studies have the added advantage of being able to visualize the ventricular chamber in the anterior or even the right anterior oblique view, but are even more limited by their spatial resolution problems. Several investigations have shown that digital subtraction angiography produces left ventricular images with a spatial resolution almost identical to that of conventional contrast ventriculography, but without the inherent problems of cardiac arrhythmias, which often limit the assessment of left ventricular function. Because of its ability to accurately delineate wall motion abnormalities, the technique may provide an adequate assessment of global and regional left ventricular function after exercise. Digital subtraction angiography may identify ischemic wall motion abnormalities produced by exercise in patients who already had significant permanent left ventricular damage from myocardial infarction

  2. Method and apparatus for performing digital intravenous subtraction angiography

    International Nuclear Information System (INIS)

    Stein, J.A.

    1986-01-01

    This invention relates to digital intravenous subtraction angiography (DISA), and more particularly concerns novel apparatus and techniques for providing high resolution angiograms with equipment that coacts with existing standard medical X-ray equipment. A typical medical X-ray generator provides low mA, continuous X-ray exposures illuminating a standard image intensifier producing an image scanned by a conventional television camera to produce a video signal. An analog-to-digital converter digitizes the signal, and adding means adds the digital frame signals together in real time to provide an intermediate digital signal representing the addition of 5 to 20 frames. Digital storage means store the intermediate image signals. Preferably there are two system memories with means for summing a subsequent intermediate image in the second memory while a previously-formed intermediate image is being transferred to disk storage

  3. Intravenous digital subtraction angiography in patients with cerebral ischaemia

    International Nuclear Information System (INIS)

    Mantoni, M.; Neergaard, K.

    1989-01-01

    Over a two-year period, 167 patients with symptoms of transient ischaemic attacks or suspected minor stroke underwent intravenous digital subtraction angiography (DSA) of the carotid arteries. There were no major complications. Ninety-six patients had abnormal angiograms, 60 normal studies, and in 11 patients (7%) the examination was not of diagnostic quality, mostly because of motion artifacts. In 86 patients no therapeutic consequences resulted from the DSA examination. Twenty-six patients were referred for vascular surgery, and 34 patients had either anticoagulation or aspirin therapy. In 10 patients a primary medical cause was found for their cerebral vascular symptoms. It is concluded that intravenous DSA of the carotid arteries in patients with transient ischaemic attack is a safe, diagnostically useful procedure, that can also be used on an outpatient basis. (orig.)

  4. Mycotic aneurysms in intravenous drug abusers: the utility of intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Shetty, P.C.; Krasicky, G.A.; Sharma, R.P.; Vemuri, B.R.; Burke, M.M.

    1985-01-01

    Two-hundred thirteen intravenous digital subtraction angiographic (DSA) examinations were performed on 195 intravenous drug abusers to rule out the possibility of a mycotic aneurysm in a groin, neck, or upper extremity infection. Twenty-three surgically proved cases of mycotic aneurysm were correctly identified with no false positive results. In addition, six cases of major venous occlusion were documented. The authors present the results of their experience and conclude that DSA is an effective and cost-efficient method of examining this high risk patient population

  5. Intravenous digital subtraction angiography investigation of reversible cerebral ischemia

    International Nuclear Information System (INIS)

    Pistolesi, G.F.; Maso, R.; Filosto, L.; Piovan, E.; Morgante, D.; Taddei, G.; Tonegutti, M.; Portuese, A.

    1986-01-01

    The brachio-cephalic, carotid, vertebral and intra-cranial vessels of 497 patients presenting reversible ischemic attacks (R.I.A) were evaluated with venous digital subtraction angiography (V.D.S.A.). Alterations of the vascular wall were observed in 289/497 (58.2%) patients, of whom 60% presented multiple locations (539 lesions): obstruction (12%), stenosis >50% (29%), stenosis 50%. The incidence of vascular lesions was higher (p [fr

  6. Videodensitometric ejection fraction from intravenous digital subtraction right ventriculograms: correlation with first pass radionuclide ejection fraction

    Energy Technology Data Exchange (ETDEWEB)

    Detrano, R.; MacIntyre, W.; Salcedo, E.E.; O' Donnell, J.; Underwood, D.A.; Simpfendorfer, C.; Go, R.T.; Butters, K.; Withrow, S.

    1985-06-01

    Thirty-one consecutive patients undergoing intravenous blurred mask digital subtraction right ventriculography were submitted to first pass radionuclide angiography. Second order mask resubtraction of end-diastolic and end-systolic right ventricular digital image frames was executed using preinjection end-diastolic and end-systolic frames to rid the digital subtraction images of mis-registration artifact. End-diastolic and end-systolic perimeters were drawn manually by two independent observers with a light pen. Ejection fractions calculated from the integrated videodensitometric counts within these perimeters correlated well with those derived from the first pass radionuclide right ventriculogram (r = 0.84) and the interobserver correlation was acceptable (r = 0.91). Interobserver differences occurred more frequently in patients with atrial fibrillation and in those whose tricuspid valve planes were difficult to discern on the digital subtraction right ventriculograms. These results suggest that videodensitometric analysis of digital subtraction right ventriculograms is an accurate method of determining right ventricular ejection fraction and may find wide clinical applicability.

  7. The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography

    International Nuclear Information System (INIS)

    Schueltke, E.; Fiedler, S.; Kelly, M.; Griebel, R.; Juurlink, B.; LeDuc, G.; Esteve, F.; Le Bas, J.-F.; Renier, M.; Nemoz, C.; Meguro, K.

    2005-01-01

    Background: Catheterization of small-caliber blood vessels in the central nervous system can be extremely challenging. Alternatively, intravenous (i.v.) administration of contrast agent is minimally invasive and therefore carries a much lower risk for the patient. With conventional X-ray equipment, volumes of contrast agent that could be safely administered to the patient do not allow acquisition of high-quality images after i.v. injection, because the contrast bolus is extremely diluted by passage through the heart. However, synchrotron-based digital K-edge subtraction angiography does allow acquisition of high-quality images after i.v. administration of relatively small doses of contrast agent. Materials and methods: Eight adult male New Zealand rabbits were used for our experiments. Animals were submitted to both angiography with conventional X-ray equipment and synchrotron-based digital subtraction angiography. Results: With conventional X-ray equipment, no contrast was seen in either cerebral or spinal blood vessels after i.v. injection of iodinated contrast agent. However, using K-edge digital subtraction angiography, as little as 1 ml iodinated contrast agent, when administered as i.v. bolus, yielded images of small-caliber blood vessels in the central nervous system (both brain and spinal cord). Conclusions: If it would be possible to image blood vessels of the same diameter in the central nervous system of human patients, the synchrotron-based technique could yield high-quality images at a significantly lower risk for the patient than conventional X-ray imaging. Images could be acquired where catheterization of feeding blood vessels has proven impossible

  8. The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Schueltke, E. [University of Saskatchewan, Saskatoon, SK (Canada) and Walton Medical Centre, University of Liverpool (United Kingdom)]. E-mail: els433@duke.usask.ca; Fiedler, S. [EMBL, Hamburg (Germany); Kelly, M. [University of Saskatchewan, Saskatoon, SK (Canada); Griebel, R. [University of Saskatchewan, Saskatoon, SK (Canada); Juurlink, B. [University of Saskatchewan, Saskatoon, SK (Canada); LeDuc, G. [ESRF, Grenoble (France); Esteve, F. [INSERM U647-ESRF, Grenoble (France); Le Bas, J.-F. [INSERM U647-ESRF, Grenoble (France); Renier, M. [ESRF, Grenoble (France); Nemoz, C. [ESRF, Grenoble (France); Meguro, K. [University of Saskatchewan, Saskatoon, SK (Canada)

    2005-08-11

    Background: Catheterization of small-caliber blood vessels in the central nervous system can be extremely challenging. Alternatively, intravenous (i.v.) administration of contrast agent is minimally invasive and therefore carries a much lower risk for the patient. With conventional X-ray equipment, volumes of contrast agent that could be safely administered to the patient do not allow acquisition of high-quality images after i.v. injection, because the contrast bolus is extremely diluted by passage through the heart. However, synchrotron-based digital K-edge subtraction angiography does allow acquisition of high-quality images after i.v. administration of relatively small doses of contrast agent. Materials and methods: Eight adult male New Zealand rabbits were used for our experiments. Animals were submitted to both angiography with conventional X-ray equipment and synchrotron-based digital subtraction angiography. Results: With conventional X-ray equipment, no contrast was seen in either cerebral or spinal blood vessels after i.v. injection of iodinated contrast agent. However, using K-edge digital subtraction angiography, as little as 1 ml iodinated contrast agent, when administered as i.v. bolus, yielded images of small-caliber blood vessels in the central nervous system (both brain and spinal cord). Conclusions: If it would be possible to image blood vessels of the same diameter in the central nervous system of human patients, the synchrotron-based technique could yield high-quality images at a significantly lower risk for the patient than conventional X-ray imaging. Images could be acquired where catheterization of feeding blood vessels has proven impossible.

  9. Evaluation of graft patency by intravenous digital subtraction angiography after vascular reconstruction

    International Nuclear Information System (INIS)

    Kuribayashi, Sachio; Ootaki, Makoto; Watabe, Tsuneya; Matsuyama, Seiya

    1985-01-01

    Intravenous digital subtraction angiography (IVDSA) was employed to evaluate graft patency after reconstructive vascular surgery in 45 cases with various vascular diseases. IVDSA offered equally valuable information about the patency of the graft, compared with conventional arteriography. In the peripheral vascular disease, IVDSA readily demonstrated patency or occlusion of the graft, even in the complex one, and the result of evaluation by IVDSA correlated well with that inferred by postoperative change in ankle pressure index measured by Doppler ultrasound technique. In the aortic disease, IVDSA was effective to rule out stenosis or leakage at the anastomotic site of the graft, and was also useful in the detection of the patency of the reconstructed inferior mesenteric artery after surgery for abdominal aortic aneurysm. The procedure in IVDSA is simple and safe, and it can be performed on an outpatient basis. IVDSA is a reliable and valuable approach in the evaluation of the graft patency after reconstructive vascular surgery. (author)

  10. Intravenous digital subtraction angiography of the lower limbs combined with field movement (2-field DSA)

    International Nuclear Information System (INIS)

    Fritschy, P.; Terrier, F.

    1988-01-01

    We evaluated a bolus-chase technique designed to reduce the volume of contrast material and to shorten examination time during intravenous digital subtraction angiography (IV-DSA) of the lower limbs. With this technique, after a single injection of contrast material, two contiguous fields can be sequentially imaged (two-field DAS) using a step translated X-ray tube. 67 patients with peripheral vascular disease were studied. All examinations provided diagnostic information, so that in no instance additional intra-arterial injections were required. With the two-field DSA only 3.49 injections were needed in the average for five fields examined in each patient, resulting in a 30% reduction of contrast agent used. (orig.) [de

  11. Experience with intravenous digital subtraction angiography following shunting in 4 cases of congenital heart diseases

    Energy Technology Data Exchange (ETDEWEB)

    Higashidate, Masafumi; Konno, Susumu; Sumitomo, Naokata; Ito, Sango; Kobayashi, Hiroshi

    1985-01-01

    Intravenous digital subtraction angiography (IV-DSA) was performed in two patients with Fallot's tetralogy who underwent Blalock-Taussing operation, a patient with coarctation of the aortic arch who underwent extra-anastomic bypass between the ascending aorta and the descending aorta, and a patient with stenosis of the tricuspid valve who underwent Fontan type operation (anastomosis between the right atrium and the pulmonary artery). The conventional cardiac angiography was also performed for the comparison with IV-DSA in all patients. IV-DSA revealed the thickness of the subclavian artery anastomosed by Blaloch-Taussing operation, but failed to determine the accurate thickness of the pulmonary artery required for PA-index for radical surgery in cases of Fallot's tetralogy. Bypass from the ascending aorta to the descending aorta was well visualized by IV-DSA because the heart did not overlap on the image. In cases of Fontan type operation, IV-DSA permitted the visualization of blood flow from the right atrium to the pulmonary artery and the shape of the pulmonary artery. It is concluded that IV-DSA is a less invasive, simple technique to evaluate patients' condition following shunting for congenital heart diseases, as compared to the conventional method. (Namekawa, K.).

  12. Experience with intravenous digital subtraction angiography following shunting in 4 cases of congenital heart diseases

    International Nuclear Information System (INIS)

    Higashidate, Masafumi; Konno, Susumu; Sumitomo, Naokata; Ito, Sango; Kobayashi, Hiroshi

    1985-01-01

    Intravenous digital subtraction angiography (IV-DSA) was performed in two patients with Fallot's tetralogy who underwent Blalock-Taussing operation, a patient with coarctation of the aortic arch who underwent extra-anastomic bypass between the ascending aorta and the descending aorta, and a patient with stenosis of the tricuspid valve who underwent Fontan type operation (anastomosis between the right atrium and the pulmonary artery). The conventional cardiac angiography was also performed for the comparison with IV-DSA in all patients. IV-DSA revealed the thickness of the subclavian artery anastomosed by Blaloch-Taussing operation, but failed to determine the accurate thickness of the pulmonary artery required for PA-index for radical surgery in cases of Fallot's tetralogy. Bypass from the ascending aorta to the descending aorta was well visualized by IV-DSA because the heart did not overlap on the image. In cases of Fontan type operation, IV-DSA permitted the visualization of blood flow from the right atrium to the pulmonary artery and the shape of the pulmonary artery. It is concluded that IV-DSA is a less invasive, simple technique to evaluate patients' condition following shunting for congenital heart diseases, as compared to the conventional method. (Namekawa, K.)

  13. Describable ability of blood vessels in head and neck by intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Minakuchi, Kazuo; Takada, Keiji; Nakamura, Kenji

    1989-01-01

    Ninety-four patients with various symptoms of the head and neck were studied by intravenous digital subtraction angiography (IV-DSA). Abnormal findings were obesrved in 12 patients; one with aneurysm in the left internal carotid artery, and 11 with obstruction in the right middle cerebral artery (2), the right internal carotid artery (one), the left subclavian artery (one), the right vertebral artery (6), and the left vertebral artery (one). Motion artifacts were observed in 2 patients. The vertebral arteries were bilaterally equal in size in 42%, and the left vertebral artery was bigger than the right one in 38%. The superior sagittal dural sinus was clearly imaged in 94%. The incidence of excellent images was higher in the right sided than the left sided vein -- 85% vs 50% for the transverse dural sinus, 84% vs 54% for the sigmoid dural sinus, and 88% vs 57% for the jugular vein. Sites of excellent images were all of the dural sinuses and veins (37 cases), confined to the right side (37), confined to the left side (8), and undefined (12). (N.K.)

  14. Digital subtraction angiography of the heart and lungs

    International Nuclear Information System (INIS)

    Moodie, D.S.; Yiannikas, J.

    1986-01-01

    This book contains 12 chapters. Some of the chapter titles are: Physical Principles of Cardiac Digital Subtraction Angiography, The Use of Intravenous Digital Subtraction Angiography in Evaluating Patients with Complex Congenital Heart Disease, Exercise Intravenous Digital Subtraction Angiograpny, Cardiomyopathic and Cardiac Neoplastic Disease, Digital Subtraction Angiography in the Catheterization Laboratory, and Cardiac Digital Subtraction Angiography - Future Directions

  15. Intraarterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Davis, P.C.

    1987-01-01

    Digital subtraction angiography (DSA) refers to a radiographic technique of amplifying low levels of contrast from intravascular iodine into an acceptable image of vascular anatomy. Initial enthusiasm suggested that DSA using intravenous injections (IV-DSA) would eliminate most conventional film-screen angiographic studies. It was soon apparent, however, that IV-DSA examinations were often compromised in those patients who most needed a less invasive study. Indeed, only a 70 to 85 percent accuracy rate was achieved with IV-DSA, primarily due to motion artifact, poor cardiac output, overlap of pertinent vessels, and inability to resolve smaller vessels

  16. Synchrotron-based intra-venous K-edge digital subtraction angiography in a pig model: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Schueltke, Elisabeth [Departments of Surgery, University of Saskatchewan, Saskatoon, SK (Canada); Anatomy and Cell Biology, University of Saskatchewan, Saskatoon, SK (Canada); Department of Neurological Sciences, Walton Medical Centre, University of Liverpool, Liverpool L97 LJ (United Kingdom)], E-mail: e.schultke@usask.ca; Fiedler, Stefan [European Molecular Biology Laboratory (EMBL), Nottkestrasse 85, 22603 Hamburg (Germany); Nemoz, Christian [European Synchrotron Radiation Facility (ESRF), 6 rue Horowitz, 38043 Grenoble (France); Ogieglo, Lissa [Departments of Surgery, University of Saskatchewan, Saskatoon, SK (Canada); Kelly, Michael E. [Departments of Surgery, University of Saskatchewan, Saskatoon, SK (Canada); Department of Neurosurgery, Section of Cerebrovascular and Endovascular Neurosurgery, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH (United States); Crawford, Paul [Royal Veterinary College, Hawkshead Lane, North Mymms, Hatfield, Herfordshire AL9 7TA (United Kingdom); Esteve, Francois [INSERM U836-ESRF, 6 rue Horowitz, 38043 Grenoble (France); Brochard, Thierry; Renier, Michel; Requardt, Herwig; Le Duc, Geraldine [European Synchrotron Radiation Facility (ESRF), 6 rue Horowitz, 38043 Grenoble (France); Juurlink, Bernhard [Anatomy and Cell Biology, University of Saskatchewan, Saskatoon, SK (Canada); Meguro, Kotoo [Departments of Surgery, University of Saskatchewan, Saskatoon, SK (Canada)

    2010-03-15

    Background: K-edge digital subtraction angiography (KEDSA) combined with the tunability of synchrotron beam yields an imaging technique that is highly sensitive to low concentrations of contrast agents. Thus, contrast agent can be administered intravenously, obviating the need for insertion of a guided catheter to deliver a bolus of contrast agent close to the target tissue. With the high-resolution detectors used at synchrotron facilities, images can be acquired at high spatial resolution. Thus, the KEDSA appears particularly suited for studies of neurovascular pathology in animal models, where the vascular diameters are significantly smaller than in human patients. Materials and methods: This feasibility study was designed to test the suitability of KEDSA after intravenous injection of iodine-based contrast agent for use in a pig model. Four adult male pigs were used for our experiments. Neurovascular angiographic images were acquired using KEDSA with a solid state Germanium (Ge) detector at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. Results: After intravenous injection of 0.9 ml/kg iodinated contrast agent (Xenetix), the peak iodine concentrations in the internal carotid and middle cerebral arteries reached 35 mg/ml. KEDSA images in radiography mode allowed the visualization of intracranial arteries of less than 1.5 mm diameter.

  17. Digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Lackner, K.; Janson, R.; Franken, T.; Harder, T.; Thurn, P.

    1983-01-01

    Digital subtraction angiography is an advanced subtraction technique and a new field in which i.v. injection of contrast media is required. Conventional techniques involving i.v. injection of contrast media have the following drawbacks: 1. High amounts of contrast media; 2. simultaneous injection into the brachial veins of both arms; 3. poor imaging of blood vessels in regions with strongly varying X-ray absorption characteristics of the background; 4. no possibility of contrast amplification. In conventional subtraction techniques, image processing takes place as a second step after the examination, so that results are not immediately available for interpretation. Digital subtraction angiography largely avoids these drawbacks. (orig./MG) [de

  18. Detection of unruptured familial intracranial aneurysms by intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Berg, H.W.M. ter; Regional Hospital Almelo; Overtoom, T.M.D.; Ludwig, J.W.; Bijlsma, J.B.; Tulleken, C.A.F.; Willemse, J.

    1987-01-01

    The authors discuss the detection of intracranial aneurysms (IA) by means of intravenous digital angiography (ivDSA) in (a)symptomatic first degree relatives of families in which more than two or more individuals have IA. ivDSA is an almost noninvasive and low-risk diagnostic procedure. Screening, by means of ivDSA, of two affected families is described. In family I which includes 7 members with proven IA, ivDSA has been carried out in 36 asymptomatic individuals: in one, a 6x15 mm aneurysm was found at the left posterior communicating artery (PCoA). In family II, including one member with a proven IA and another with a subarachnoidal hemorrhage, ivDSA has been carried out in 4 members: one aneurysm with a diameter of 6 mm was found at the left PCoA. Conventional cerebral angiography (CCA) confirmed both IA's. Neurosurgical treatment followed. The advantages and disadvantages of ivDSA vs. CCA as elective screening procedure in such cases are discussed. Screening of asymptomatic first degree relatives of cases with familial IA by means of ivDSA is strongly advocated. (orig.)

  19. Digital subtraction angiography in ischemic cerebrovascular accidents

    International Nuclear Information System (INIS)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P.

    1983-01-01

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery [fr

  20. Intra-Arterial MR Perfusion Imaging of Meningiomas: Comparison to Digital Subtraction Angiography and Intravenous MR Perfusion Imaging.

    Directory of Open Access Journals (Sweden)

    Mark A Lum

    Full Text Available To evaluate the ability of IA MR perfusion to characterize meningioma blood supply.Studies were performed in a suite comprised of an x-ray angiography unit and 1.5T MR scanner that permitted intraprocedural patient movement between the imaging modalities. Patients underwent intra-arterial (IA and intravenous (IV T2* dynamic susceptibility MR perfusion immediately prior to meningioma embolization. Regional tumor arterial supply was characterized by digital subtraction angiography and classified as external carotid artery (ECA dural, internal carotid artery (ICA dural, or pial. MR perfusion data regions of interest (ROIs were analyzed in regions with different vascular supply to extract peak height, full-width at half-maximum (FWHM, relative cerebral blood flow (rCBF, relative cerebral blood volume (rCBV, and mean transit time (MTT. Linear mixed modeling was used to identify perfusion curve parameter differences for each ROI for IA and IV MR imaging techniques. IA vs. IV perfusion parameters were also directly compared for each ROI using linear mixed modeling.18 ROIs were analyzed in 12 patients. Arterial supply was identified as ECA dural (n = 11, ICA dural (n = 4, or pial (n = 3. FWHM, rCBV, and rCBF showed statistically significant differences between ROIs for IA MR perfusion. Peak Height and FWHM showed statistically significant differences between ROIs for IV MR perfusion. RCBV and MTT were significantly lower for IA perfusion in the Dural ECA compared to IV perfusion. Relative CBF in IA MR was found to be significantly higher in the Dural ICA region and MTT significantly lower compared to IV perfusion.

  1. Digital subtraction angiography of the thoracic aorta

    International Nuclear Information System (INIS)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-01-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram

  2. Digital subtraction angiography of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-02-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram.

  3. Assessment of the left ventricular systolic and diastolic function by the left ventricular density curve derived from intravenous digital subtraction angiography in children

    Energy Technology Data Exchange (ETDEWEB)

    Horigome, Hitoshi; Satoh, Hideo; Isobe, Takeshi; Takita, Hitoshi (Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine)

    1991-05-01

    To evaluate the left ventricular (LV) systolic and diastolic function, fifty-four children with various heart diseases underwent intravenous digital subtraction angiography (IV-DSA). Global left ventricular density curve was obtained through densitometry of the DSA images. The curve was smoothed by a third-degree Fourier transformation and systolic and diastolic indexes were obtained. In the control group, consisting of Kawasaki disease without coronary lesion and mild pulmonary stenosis, the peak ejection rate (PER) and the peak filling rate in early diastole (PFR-E) correlated positively with the heart rate (HR) in a quadratic curve manner (PER: r= 0.93 p<0.01, PFR-E: r= 0.94 p<0.01). Time from end-diastolic to PER (T-PER) and time from end-systolic to PFR (T-PFR) were correlated negatively with HR (T-PER: r=-0.86 p<0.01, T-PFR: r=-0.91 p<0.01). However, T-PER/RR and T-PFR/RR values were rather constant (20.9+-3.2%, 17.0+-2.6%, respectively). We also found significant correlations of PER and PFR-E with left ventricular ejection fraction (LVEF). Patients with corrected tetralogy of Fallot and with cardiomyopaties showed not only abnormal systolic indexes but some depressed diastolic indexes. LV density curve also disclosed isolated diastolic dysfunction in a group of aortic stenosis and in two patients with coronary lesions. A correlation of LVEF derived from the density curve and conventional area-length method was high (r= 0.91 p<0.001). To evaluate the reproducibility, we were able to obtain the digital data twice with over one month interval on 24 patients. The intraobserver correlation was satisfactory. We applied the remasking method, resulting in improving the quality of digital images under spontaneous breathing. Our results indicated that IV-DSA was a less-invasive and clinically reliable method for assessment of LV function in children. (author).

  4. Assessment of the left ventricular systolic and diastolic function by the left ventricular density curve derived from intravenous digital subtraction angiography in children

    International Nuclear Information System (INIS)

    Horigome, Hitoshi; Satoh, Hideo; Isobe, Takeshi; Takita, Hitoshi

    1991-01-01

    To evaluate the left ventricular (LV) systolic and diastolic function, fifty-four children with various heart diseases underwent intravenous digital subtraction angiography (IV-DSA). Global left ventricular density curve was obtained through densitometry of the DSA images. The curve was smoothed by a third-degree Fourier transformation and systolic and diastolic indexes were obtained. In the control group, consisting of Kawasaki disease without coronary lesion and mild pulmonary stenosis, the peak ejection rate (PER) and the peak filling rate in early diastole (PFR-E) correlated positively with the heart rate (HR) in a quadratic curve manner [PER: r= 0.93 p<0.01, PFR-E: r= 0.94 p<0.01]. Time from end-diastolic to PER (T-PER) and time from end-systolic to PFR (T-PFR) were correlated negatively with HR [T-PER: r=-0.86 p<0.01, T-PFR: r=-0.91 p<0.01]. However, T-PER/RR and T-PFR/RR values were rather constant (20.9±3.2%, 17.0±2.6%, respectively). We also found significant correlations of PER and PFR-E with left ventricular ejection fraction (LVEF). Patients with corrected tetralogy of Fallot and with cardiomyopaties showed not only abnormal systolic indexes but some depressed diastolic indexes. LV density curve also disclosed isolated diastolic dysfunction in a group of aortic stenosis and in two patients with coronary lesions. A correlation of LVEF derived from the density curve and conventional area-length method was high [r= 0.91 p<0.001]. To evaluate the reproducibility, we were able to obtain the digital data twice with over one month interval on 24 patients. The intraobserver correlation was satisfactory. We applied the remasking method, resulting in improving the quality of digital images under spontaneous breathing. Our results indicated that IV-DSA was a less-invasive and clinically reliable method for assessment of LV function in children. (author)

  5. Physical principles of cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Buonocore, E.; Pavlicek, W.

    1986-01-01

    Advances in the applications of computers with standard radiologic equipment have resulted in the development of electronic, or so-called ''film-less'' imaging. This technique, discussed by the authors, has become of particular value in the visualization of the central vascular system and has become known as digital subtraction angiography (DSA). Commercial products have become increasingly available and are capable of converting T.V. signals, obtained by conventional fluorography, to a computed array of digital values. Addition, subtraction, and averaging of this data, result in images with adequate signal-to-noise ratios that achieve detection of low concentrations of contrast media not possible with conventional screen film techniques. Computer subtraction of unnecessary background information improves the conspicuity of the opacified vessels to permit detection of vascular structures containing a concentration of no more than 1-3 percent of contrast media. This improved visualization is possible even with intravenous peripheral injections or reduced amounts of contrast media given intraarterially. With either method of contrast media administration, DSDA has become an excellent means of anatomic demonstration of the heart and great vessels with decreased morbidity and at lower cost

  6. Digital subtraction angiography system evaluation with phantoms

    International Nuclear Information System (INIS)

    Wenstrup, R.S.; Sweeney, K.P.; Scholz, F.J.

    1985-01-01

    Advances in digital subtraction angiography imaging demonstrate the need for critical evaluation of the performance of digital subtraction equipment. The design of a phantom set for noninvasive assessment of the imaging quality of digital subtraction equipment is described; components include a remotely controlled transport system and individual patterns to evaluate the contrast and detail properties of the image intensifier, low-contrast sensitivity and resolution of the system, geometric distortion of image, linearity, mechanical and electronic stability of equipment, and effects of bone and bowel gas on iodine perception. The performance of an add-on digital radiographic system is presented, along with radiation exposure levels at the image intensifier for a range of radiographic techniques

  7. Digital subtraction angiography of carotid bifurcation

    International Nuclear Information System (INIS)

    Vries, A.R. de.

    1984-01-01

    This study demonstrates the reliability of digital subtraction angiography (DSA) by means of intra- and interobserver investigations as well as indicating the possibility of substituting catheterangiography by DSA in the diagnosis of carotid bifurcation. Whenever insufficient information is obtained from the combination of non-invasive investigation and DSA, a catheterangiogram will be necessary. (Auth.)

  8. Digital subtraction angiography: myths and reality

    International Nuclear Information System (INIS)

    Levin, D.C.

    1984-01-01

    Some of the claims made about digital subtraction angiography (DSA) when it was first developed have turned out to be greatly exaggerated, and some members of the radiologic community have become disillusioned with its capabilities. The author discusses some of the limitations of DSA, and concludes that the advantages of DSA outweigh its limitations

  9. Development of Shimadzu digital subtraction system

    International Nuclear Information System (INIS)

    Nishioka, Hiroyuki; Shibata, Koichi; Shimizu, Yasumitsu; Shibata, Kenji; Wani, Hidenobu

    1985-01-01

    Shimadzu has recently developed a digital subtraction system. It can perform intra-arterial digital subtraction angiography (DSA) using low concentration of contrast medium, or can visualize arteries with intravenuous injection. It can extremely reduce patient's pain in angiography. Image quality of DSA has been much improved by the development of high quality image amplifiers, improvement of signal-to-noise ratio of the x-ray television unit and the development of digital disk recorders. The peak-hold subtraction method that is now under clinical study presents images of blood vessels as the trace of the flow of contrast medium. The maximum-hold memory where the maximum value of the brightness in some period is stored for every picture element is subtracted from the minimum-hold memory where the minimum value is stored, and thus images of blood vessels can be obtained. Hardware of this method is rather simple and it is expected that the amount of contrast medium may be reduced or x-ray dose of the patient may be decreased. (author)

  10. Digital subtraction angiography in head and neck radiology

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, R.F.; Seeger, J.F.; Smith, R.L.; Horsley, W.W.; Miller, R.W.

    1984-07-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally.

  11. Digital subtraction angiography in head and neck radiology

    International Nuclear Information System (INIS)

    Carmody, R.F.; Seeger, J.F.; Smith, R.L.; Horsley, W.W.; Miller, R.W.

    1984-01-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally. (orig.)

  12. Digital Subtraction Fluoroscopic System With Tandem Video Processing Units

    Science.gov (United States)

    Gould, Robert G.; Lipton, Martin J.; Mengers, Paul; Dahlberg, Roger

    1981-07-01

    A real-time digital fluoroscopic system utilizing two video processing units (Quantex) in tandem to produce continuous subtraction images of peripheral and internal vessels following intravenous contrast media injection has been inves-tigated. The first processor subtracts a mask image consisting of an exponentially weighted moving average of N1 frames (N1 = 2k where k = 0.7) from each incoming video frame, divides by N1, and outputs the resulting difference image to the second processor. The second unit continuously averages N2 incoming frames (N2 = 2k) and outputs to a video monitor and analog disc recorder. The contrast of the subtracted images can be manipulated by changing gain or by a non-linear output transform. After initial equipment adjustments, a subtraction sequence can be produced without operator interaction with the processors. Alternatively, the operator can freeze the mask and/or the subtracted output image at any time during the sequence. Raw data is preserved on a wide band video tape recorder permitting retrospective viewing of an injection sequence with different processor settings. The advantage of the tandem arrangement is that it has great flexibility in varying the duration and the time of both the mask and injection images thereby minimizing problems of registration between them. In addition, image noise is reduced by compiling video frames rather than by using a large radiation dose for a single frame, which requires a wide dynamic range video camera riot commonly available in diagnostic x-ray equipment. High quality subtraction images of arteries have been obtained in 15 anesthetized dogs using relatively low exposure rates (10-12 μR/video frame) modest volumes of contrast medium (0.5-1 ml/kg), and low injection flow rates (6-10 ml/sec). The results/ achieved so far suggest that this system has direct clinical applications.

  13. Digital Subtraction Radiography - A Technique Revisited

    Directory of Open Access Journals (Sweden)

    Anshul Mehra

    2007-01-01

    Full Text Available Digital imaging has changed the scenario of medical and dental imaging as it has been able to address many limitations associated with traditional film based radiograph. However, subtle changes on the image are still difficult to appreciate by the human eye because the changes are buried in a background of normal anatomic structures, and are not clearly evident. Digital subtraction radiography is one of the image enhancing technique which addresses this problem and has found its use in various fields of dentistry in the recent past. However, there is lack of review in the literature regarding this widely used technique. The purpose of this article is to present an overview of this technique and its uses in various fields of dentistry.

  14. Digital Subtraction Angiography (DSA) "Road Map": An Angiographic Tool

    Science.gov (United States)

    Turski, P. A.; Stieghorst, M. F.; Strother, C. M.; Crummy, A. B.; Lieberman, R. P.; Mistretta, C. A.

    1982-12-01

    Continuous Digital subtraction combined with intraarterial injections of contrast medium permits the display of arterial structures during real time fluoroscopy. This DSA "road map" facilitates selective catheterization and has proved useful in interventional procedures.

  15. Digital contrast subtraction radiography for proximal caries diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Byung Cheol; Yoon, Suk Ja [Department of Dental Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2002-06-15

    To determine whether subtraction images utilizing contrast media can improve the diagnostic performance of proximal caries diagnosis compared to conventional periapical radiographic images. Thirty-six teeth with 57 proximal surfaces were radiographied using a size no.2 RVG-ui sensor (Trophy Radiology, Marne-la-Vallee, France). The teeth immersed in water-soluble contrast media and subtraction images were taken. Each tooth was then sectioned for histologic examination. The digital radiographic images and subtraction images were examined and interpreted by three dentists for proximal caries. The results of the proximal caries diagnosis were then verified with the results of the histologic examination. The proximal caries sensitivity using digital subtraction radiography was significantly higher than simply examining a single digital radiograph. The sensitivity of the proximal dentinal carious lesion when analyzed with the subtraction radiograph and the radiograph together was higher than with the subtraction radiograph or the radiograph alone. The use of subtraction radiography with contrast media may be useful for detecting proximal dentinal carious lesions.

  16. Digital contrast subtraction radiography for proximal caries diagnosis

    International Nuclear Information System (INIS)

    Kang, Byung Cheol; Yoon, Suk Ja

    2002-01-01

    To determine whether subtraction images utilizing contrast media can improve the diagnostic performance of proximal caries diagnosis compared to conventional periapical radiographic images. Thirty-six teeth with 57 proximal surfaces were radiographied using a size no.2 RVG-ui sensor (Trophy Radiology, Marne-la-Vallee, France). The teeth immersed in water-soluble contrast media and subtraction images were taken. Each tooth was then sectioned for histologic examination. The digital radiographic images and subtraction images were examined and interpreted by three dentists for proximal caries. The results of the proximal caries diagnosis were then verified with the results of the histologic examination. The proximal caries sensitivity using digital subtraction radiography was significantly higher than simply examining a single digital radiograph. The sensitivity of the proximal dentinal carious lesion when analyzed with the subtraction radiograph and the radiograph together was higher than with the subtraction radiograph or the radiograph alone. The use of subtraction radiography with contrast media may be useful for detecting proximal dentinal carious lesions.

  17. [A digital subtraction angiography system based on LUT algorithms].

    Science.gov (United States)

    Chen, Xiangan; Li, Kaiyang; Zhou, Li; Chen, Jiansheng

    2006-04-01

    Look-up table (LUT) algorithms have been widely used in digital signal processing, but the article on the application of LUT algorithms in digital subtraction angiography was rarely reported. In this article, the effect of different LUT algorithms on digital subtraction angiography images is introduced. The result reveals that different LUT algorithms can bring about different effects of image. Based on analysis and comparison, we deem it possible to acquire improved images of DSA by use of some LUT algorithms with image processing.

  18. Digital subtraction radiography in the study of the lacrimal system

    International Nuclear Information System (INIS)

    Falaschi, F.; Pieri, L.; Perri, G.; Signorini, G.; Genovese Ebert, F.

    1988-01-01

    The authors emphasize the usefulness of digital dacrycystography (DCG), as compared with various current technoques. Utilizing a radiographic unit equipped with a video-fluoroscopic system and interfaced to a digital video-processor, several digitalized images are acquired before, during and after the injection of contrast medium. Final images are obtained by subtraction of suitable pairs of source frames. Twenty-six patients affected by epiphora have been examined so far. In 21 cases digital subtraction DCG allowed an accurate visualization of the lacrimal system; in the other five patients the amount of information was acceptable. This methodology allows the assessment of both the normal anatomy of the lacrimal passages and their pathological patterns, such as obstructions, stenoses, fistulas, chronic dacrycystites, lacrimal stones. The examination is easy and quick to perform, with no discomfort for the patient. Digital subtraction DCG proves thus to be a very valuable technique thanks to its possible electronic elaboration - i.e. the subtraction and the magnification of images - to its better contrast resolution, and to the possibility it yields of dynamic studies under radioscopic control

  19. Digital subtraction angiography in the diagnosis of Fallot's tetralogy

    International Nuclear Information System (INIS)

    Ivanitskij, A.V.; Tereshkin, Ya.A.; Sobolev, A.V.; Stolyar, V.L.; Slyunyastikov, M.A.

    1995-01-01

    The authors analyze the efficacy of digital subtraction angiography (DSA) in the diagnosis of Fallot's tetralogy (FT); this method helps simplity and cut down their scope of investigations but does not deteriorate their informative value. DSA findings in 120 patients with TF are analyzed. 5 refs.; 6 figs

  20. Pulmonary ventilation in children digital subtraction study

    International Nuclear Information System (INIS)

    Schmit, P.; Faure, C.; Sardet, A.; Bacques, O.

    1985-01-01

    Digital technique such as used in digital angiography can be used to study areas which lucency varies with time. A TID technique (time interval difference) has been used to study the lucency variation of the lung in children. This method has been used in 130 children with a mean age of 2 years and 8 months. In 85 children, the TID was normal: 5 false negative studies were found in this group. In the other 47 cases, the anomaly of the TID was due to a perfusion or a ventilation anomaly or both. No false positive are found. In 13 patients, comparison between the TID findings and the perfusion and ventilation nuclear scan was possible. In 9 patients, the correlation was excellent, the TID giving more some informations about the pulmonary mixic [fr

  1. Digital subtraction angiography in the assessment of cardiovascular disease

    International Nuclear Information System (INIS)

    Harrington, D.P.; Boxt, L.M.

    1985-01-01

    Digital subtraction angiography (DSA) is a new radiographic method for evaluating the cardiovascular system. It represents another in a continuing series of computer-assisted diagnostic imaging modalities. The advantages of this technique are its relatively noninvasive nature combined with diagnostically acceptable angiographic images of a variety of cardiovascular structures. Major clinical applications of DSA include its use in imaging of localized regions of peripheral arterial disease and as a screening procedure in evaluating extracranial carotid and vertebral artery disease and renovascular hypertension. Cardiac applications of DSA include assessment of ventricular function, recognition and quantification of intracardiac shunts, visualization of coronary artery bypass grafts, and the study of complex congenital cardiac malformations. Digital subtraction angiography may also be used to evaluate intracranial aneurysms and vascular tumors

  2. Digital subtraction angiography in pediatric cerebrovascular occlusive disease

    International Nuclear Information System (INIS)

    Faerber, E.N.; Griska, L.A.B.; Swartz, J.D.; Capitanio, M.A.; Popky, G.L.

    1984-01-01

    While conventional angiography has been used to demonstrate cerebrovascular occlusive disease in the past, digital subtraction angiography (DSA) is capable of showing progressive vascular involvement with ease, simplicity, and extremely low morbidity, making it particularly well suited for children and outpatients either alone or coordinated with computed tomography. The authors discuss the usefulness and advantages of DSA as demonstrated in 7 infants and children with hemiplegia, 4 of whom had sickle-cell disease

  3. Introduction to the principles of Digital Subtraction Angiography (DSA)

    International Nuclear Information System (INIS)

    Kaplanis, P.

    1997-01-01

    Medical applications of advanced technology have rapidly become more sophisticated and more widespread. The field of diagnostic imaging is by no means an exception. There has been a number of breathtaking developments in the field of medical imaging in recent years. Today higher quality, greater clarity and more minute precision are considered not advantages but necessities. Hence new developments are concentrated in the data acquisition and image processing based on the microprocessor controlled modules interfaced with state of the art radiological imaging equipment. One such development is the subtraction of x-rays vis a computer for better visualization of blood vessels, cavities of the heart and of the coronary and pulmonary vascular system. This procedure is termed Digital Subtraction Angiography (DSA). (author)

  4. Assessment of simulated internal resorption cavities using digital and digital subtraction radiography: a comparative study.

    Science.gov (United States)

    Stephanopoulos, Georgios; Mikrogeorgis, Georgios; Lyroudia, Kleoniki

    2011-10-01

    To compare the diagnostic accuracy of digital radiography with that of digital subtraction radiography in the detection of simulated internal resorption cavities. Simulated internal resorption cavities of varying sizes were created using round burs in 18 single-rooted teeth with visible pulp chamber, which had been extracted from dentate dry mandibles and split into two halves in a mesio-distal direction. Resorption cavities were created in the buccal half of the root in the cervical, middle, and apical third. Digital radiographs were taken from three different horizontal view angles before and after the creation of the cavities. This process was followed by digital subtraction radiography to evaluate their detection. Seven experienced observers and all specialists in endodontics were asked to examine the digital and digital subtraction images for the presence of the cavities. The data were analyzed using SPSS 14. The overall sensitivity of digital subtraction radiography was superior to digital radiography and with statistically better results for all cavities regardless of their location (cervical, middle, apical third) (P < 0.05). The detection of the cavities was affected by the root third in which they were located. Cavities in the apical third were more easily detected compared with those in the middle or cervical third of the root. Small-sized lesions (0.5 mm, 0.6 mm) in the middle and apical third were more frequent and more easily detected using subtraction imaging. Digital subtraction radiography is superior to digital radiography for the detection and monitoring of the progress of internal root resorption. © 2011 John Wiley & Sons A/S.

  5. Evaluation and quality control of digital subtraction angiography systems

    International Nuclear Information System (INIS)

    Louisot, P.

    1986-04-01

    After reviewing the development of systems used in angiography, we rewind the medical interest and describe the steps of an angiographic examination. The following chapter is dedicated to the techniques used for the digitalization of video images. The components of the system involved in the image acquisition are thoroughly investigated in chapter 4. Then, we analyse the capabilities of the machines available in France in 1985. Chapter 6 is devoted to the criteria of quality in digital imaging. In order to assign qualitative values to the above criteria, we design a control procedure which is described in chapter 7. The procedure thus allows the estimate of the physical performances of angiographic digital subtraction systems [fr

  6. Evaluation of left ventricular function using digital subtraction ventriculography

    International Nuclear Information System (INIS)

    Yiannikas, J.; Detrano, R.

    1986-01-01

    Digital subtraction ventriculography following injections of contrast via peripheral veins provides excellent images to assess left ventricular function. The images are essentially identical to those following DCV, but allow more uniform mixing of contrast in the left ventricular chamber. Furthermore, few, if any, cardiac arrhythmias occur, hence obviating difficulties that arise from DCV. The spatial resolution of the method is such that regional wall motion assessment of ventricular function is more accurate than that of other noninvasive imaging methods. The use of video-densitometry allows accurate assessment of left ventricular function even when the left ventricular cavity is nonsymmetrically deformed and aneurysmal. In the setting of the cardiac catheterization laboratory, digital ventriculography may provide a safer means of assessing left ventricular function when critical coronary or myocardial disease is present and allows multiple assessments of ventricular function during the same study. Although excellent correlations with standard ventriculography have been noted by all workers, significant discrepancies still exist in individual patients, particularly in the calculations of end diastolic volumes. In the authors experience and in those of most workers, the largest discrepancies existed in patients in whom suboptimal studies are included for analysis. The most frequent reason for the occasional suboptimal study as with all digital subtraction work is the misregistration that results from motion

  7. [Design and development of the DSA digital subtraction workstation].

    Science.gov (United States)

    Peng, Wen-Xian; Peng, Tian-Zhou; Xia, Shun-Ren; Jin, Guang-Bo

    2008-05-01

    According to the patient examination criterion and the demands of all related departments, the DSA digital subtraction workstation has been successfully designed and is introduced in this paper by analyzing the characteristic of video source of DSA which was manufactured by GE Company and has no DICOM standard interface. The workstation includes images-capturing gateway and post-processing software. With the developed workstation, all images from this early DSA equipment are transformed into DICOM format and then are shared in different machines.

  8. Real-time digital x-ray subtraction imaging

    International Nuclear Information System (INIS)

    Mistretta, C.A.; Kruger, R.A.; Houk, T.L.

    1982-01-01

    A method of producing visible difference images derived from an x-ray image of an anatomical subject is described. X-rays are directed through the subject, and the image is converted into television fields comprising trains of analog video signals. The analog signals are converted into digital signals, which are then integrated over a predetermined time corresponding to several television fields. Difference video signals are produced by performing a subtraction between the ongoing video signals and the corresponding integrated signals, and are converted into visible television difference images representing changes in the x-ray image

  9. IMPROVED BACKGROUND SUBTRACTION FOR THE SLOAN DIGITAL SKY SURVEY IMAGES

    International Nuclear Information System (INIS)

    Blanton, Michael R.; Kazin, Eyal; Muna, Demitri; Weaver, Benjamin A.; Price-Whelan, Adrian

    2011-01-01

    We describe a procedure for background subtracting Sloan Digital Sky Survey (SDSS) imaging that improves the resulting detection and photometry of large galaxies on the sky. Within each SDSS drift scan run, we mask out detected sources and then fit a smooth function to the variation of the sky background. This procedure has been applied to all SDSS-III Data Release 8 images, and the results are available as part of that data set. We have tested the effect of our background subtraction on the photometry of large galaxies by inserting fake galaxies into the raw pixels, reanalyzing the data, and measuring them after background subtraction. Our technique results in no size-dependent bias in galaxy fluxes up to half-light radii r 50 ∼ 100 arcsec; in contrast, for galaxies of that size the standard SDSS photometric catalog underestimates fluxes by about 1.5 mag. Our results represent a substantial improvement over the standard SDSS catalog results and should form the basis of any analysis of nearby galaxies using the SDSS imaging data.

  10. Real-time digital X-ray subtraction imaging

    International Nuclear Information System (INIS)

    Mistretta, C.A.; Kruger, R.A.; Houk, T.L.

    1979-01-01

    A diagnostic anatomical X-ray apparatus comprising a converter and a television camera for converting an X-ray image of a subject into a series of television fields of video signals is described in detail. A digital memory system stores and integrates the video signals over a time interval corresponding to a plurality of successive television fields. The integrated video signals are recovered from storage and fed to a digital or analogue subtractor, the resulting output being displayed on a television monitor. Thus the display represents on-going changes in the anatomical X-ray image. In a modification, successive groups of fields are stored and integrated in three memories, cyclically, and subtractions are performed between successive pieces of integrated signals to provide a display of successive alterations in the X-ray image. For investigations of the heart, the integrating interval should be of the order of one cardiac cycle. (author)

  11. Digital subtraction angiography in 105 living renal transplant donors

    International Nuclear Information System (INIS)

    Suh, Ho Jong; Oh, Kyung Seung; Kim, So Sun; Huh, Jin Do; Kim, Ho Joon; Chun, Byung Hee; Joh, Young Duck

    1989-01-01

    In order to analyze the number and length of the renal arteries and to evaluate abnormalities of the renal parenchyma and vessel, digital subtraction angiogram images of 105 potential renal donors (45 men and 60 women aged 17-66 years) were studied retrospectively. For the entire series, 31 donors had multiple renal arteries on one side (15 on the left, 11 on the right) and 5 donors on the both sides. 89 donors were family related either parents or siblings of recipients. The estimation of the length of the renal artery was based on the mean height of the second lumbar vertebral body (L2). The right renal artery is significant longer than on the left and measured more than the height of L2 vertebral body in 84 cases on the right and 60 cases on the left. Twenty two donors underwent right nephrectomy due to presence of multiple renal arteries on the left (N=14), proximal bifurcation of left main renal artery (N=3), and young females in reproductive age (N=5). Unexpected abnormalities found with angiogram were seen in 7 cases and they include renal artery stenosis (N=2), renal cysts (N=4) and focal infarction (N=1). In cases of the renal cysts and focal infarction, there were no serious complications related to the abnormalities. It is conclude that intra-arterial digital subtraction angiography is safe and efficient method to image renal anatomy of the potential renal donors

  12. Combined nuclear and digital subtraction contrast arthrography in painful knee prosthesis

    Energy Technology Data Exchange (ETDEWEB)

    Namasivayam, J.; Forrester, A. (Royal Infirmary, Glasgow (United Kingdom). Dept. of Radiology); Poon, F.W.; Cuthbert, G.F.; McKillop, J.H. (Royal Infirmary, Glasgow (United Kingdom). Dept. of Nuclear Medicine); Bryan, A.S.

    1992-06-01

    The evaluation of a painful knee prosthesis remains a difficult problem for both orthopaedic surgeons and radiologists. We have compared digital subtraction arthrography with nuclear-arthrography in 7 patients with a painful knee prosthesis. Three patients showed a loose tibial component, demonstrated by both digital subtraction and nuclear arthrography. All 3 underwent revision of their prosthesis. One patient had an equivocal digital subtraction arthrogram and negative nuclear arthrogram, while both studies were negative in the 3 remaining patients. Nuclear arthrography is a simple procedure and can provide useful additional information when combined with digital subtraction arthrography. (orig.).

  13. Using a digital signal processor as a data stream controller for digital subtraction angiography

    International Nuclear Information System (INIS)

    Meng, J.D.; Katz, J.E.

    1991-10-01

    High speed, flexibility, and good arithmetic abilities make digital signal processors (DSP) a good choice as input/output controllers for real time applications. The DSP can be made to pre-process data in real time to reduce data volume, to open early windows on what is being acquired and to implement local servo loops. We present an example of a DSP as an input/output controller for a digital subtraction angiographic imaging system. The DSP pre-processes the raw data, reducing data volume by a factor of two, and is potentially capable of producing real-time subtracted images for immediate display

  14. Digital subtraction CT angiography for the detection of posterior inferior cerebellar artery aneurysms: comparison with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Guo Zhong; Luo, Song; Zhou, Chang Sheng; Zhang, Long Jiang; Lu, Guang Ming [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China)

    2017-09-15

    To evaluate the diagnostic accuracy of digital subtraction CT angiography (DS-CTA) in detecting posterior inferior cerebellar artery (PICA) aneurysms with digital subtraction angiography (DSA) as reference standard. A total of 115 patients, including 56 patients diagnosed with PICA aneurysms by CTA or DSA and 59 non-PICA-aneurysm patients were included in this retrospective study. All patients underwent DS-CTA and DSA. The site of PICA aneurysms and the pattern of haemorrhage were analysed. Sensitivity and specificity of DS-CTA without and with combining haemorrhage pattern in diagnosing PICA aneurysms were evaluated on a per patient and per aneurysm basis with DSA. Of 115 patients, 56 patients (48.7%) had 61 PICA aneurysms (size range, 1.1-13.5 mm; mean size, 4.9 ± 2.8 mm) on DSA. The sensitivity and specificity in depicting PICA aneurysms were 89.3% and 96.6% on a per patient basis and 90.2% and 93.4% on a per aneurysm basis, while the corresponding values were 94.6% and 96.6% on a per patient basis and 95.1% and 93.4% on a per aneurysm basis when combining with haemorrhage site. DS-CTA has a high sensitivity and specificity in detecting PICA aneurysms compared with DSA. It may be helpful for clinical diagnosis of PICA aneurysms to combine with haemorrhage sites. (orig.)

  15. Videodensitometric assessment of right and left ventricular functions by digital subtraction angiography

    International Nuclear Information System (INIS)

    Ikeda, Hisao; Yoshiga, Osamu; Shibao, Keigo

    1987-01-01

    Intravenous digital subtraction (DS) ventriculography was performed in a series of 50 patients with heart diseases to determine right and left ventricular volumes and systolic indices. Right ventricular volume and right ventricular ejection fraction obtained by DS ventriculography were well correlated with those by geometric methods. In 43 patients with left ventricular ejection fraction of 55 % or greater, end-diastolic volume, stroke volume, and ejection fraction in the right ventricle did not differ from those in the left ventricle ; however, both the 1/3 ejection fraction and the peak ejection rate of the right ventricle were significantly lower than those of the left ventricle, suggesting the different modes of left and right ventricular contraction. In the other seven patients with chronic left ventricular failure, right ventricular systolic function may be preserved, even when left ventricular function is severely impaired. Digital subtraction ventriculography has proved to be a simple, useful method in the quanlitative and quantitative assessments of the right and left ventricles. (Namekawa, K.)

  16. Real-time digital x-ray subtraction imaging

    International Nuclear Information System (INIS)

    Mistretta, C.A.

    1982-01-01

    The invention provides a method of producing visible difference images derived from an X-ray image of an anatomical subject, comprising the steps of directing X-rays through the anatomical subject for producing an image, converting the image into television fields comprising trains of on-going video signals, digitally storing and integrating the on-going video signals over a time interval corresponding to several successive television fields and thereby producing stored and integrated video signals, recovering the video signals from storage and producing integrated video signals, producing video difference signals by performing a subtraction between the integrated video signals and the on-going video signals outside the time interval, and converting the difference signals into visible television difference images representing on-going changes in the X-ray image

  17. Evaluation of the cardiovascular system by digital subtraction angiography in 246 patients

    Energy Technology Data Exchange (ETDEWEB)

    Higuma, Kikuhiko; Ohta, Takashi; Hiroto, Seiji

    1987-07-01

    Usefulness of intravenous digital subtraction angiography (DSA) was examined in 246 patients with cardiovascular disorders. This examination was done by centrally intravenous DSA (CIVDSA) in all patients to reduce the risks and discomforts by peripheral intravenous DSA. 1) CIVDSA could be done safely in patients aged 18 to 81 years. 2) The good diagnostic quality by CIVDSA was obtained in 81.3% of patients. These images were classified into 7 groups according to the cardiovascular system, that is, the jugular arteries, the upper extremity arteries, the thoracic aorta, the left ventricle, the abnominal aorta, the renal arteries, and the lower extremity arteries, whose rate of good diagnostic quality were 100%, 70%, 67.7%, 79.5%, 84.8%, 87%, and 71.4% respectively. 3) The poor diagnostic quality was obtained in 18.7%. 4) The severe complications were not found in any case during this examination. Our results indicate that DSA is the safe, simple and useful method to obtain the diagnostic quality image of the cardiovascular system, especially, of the occulsive arterial disease, the aortic aneurisma, the renovascular stenosis and the cardiac function of postmyocardial infarction, even in aged patients.

  18. Evaluation of the cardiovascular system by digital subtraction angiography in 246 patients

    International Nuclear Information System (INIS)

    Higuma, Kikuhiko; Ohta, Takashi; Hiroto, Seiji

    1987-01-01

    Usefulness of intravenous digital subtraction angiography (DSA) was examined in 246 patients with cardiovascular disorders. This examination was done by centrally intravenous DSA (CIVDSA) in all patients to reduce the risks and discomforts by peripheral intravenous DSA. 1) CIVDSA could be done safely in patients aged 18 to 81 years. 2) The good diagnostic quality by CIVDSA was obtained in 81.3 % of patients. These images were classified into 7 groups according to the cardiovascular system, that is, the jugular arteries, the upper extremity arteries, the thoracic aorta, the left ventricle, the abnominal aorta, the renal arteries, and the lower extremity arteries, whose rate of good diagnostic quality were 100 %, 70 %, 67.7 %, 79.5 %, 84.8 %, 87 %, and 71.4 % respectively. 3) The poor diagnostic quality was obtained in 18.7 %. 4) The severe complications were not found in any case during this examination. Our results indicate that DSA is the safe, simple and useful method to obtain the diagnostic quality image of the cardiovascular system, especially, of the occulsive arterial disease, the aortic aneurisma, the renovascular stenosis and the cardiac function of postmyocardial infarction, even in aged patients. (author)

  19. Assessment of blood supply to intracranial pathologies in children using MR digital subtraction angiography

    International Nuclear Information System (INIS)

    Chooi, Weng Kong; Coley, Stuart C.; Connolly, Dan J.A.; Griffiths, Paul D.

    2006-01-01

    MR digital subtraction angiography (MR-DSA) is a contrast-enhanced MR angiographic sequence that enables time-resolved evaluation of the cerebral circulation. We describe the feasibility and technical success of our attempts at MR-DSA for the assessment of intracranial pathology in children. We performed MR-DSA in 15 children (age range 5 days to 16 years) referred for MR imaging because of known or suspected intracranial pathology that required a dynamic assessment of the cerebral vasculature. MR-DSA consisted of a thick (6-10 mm) slice-selective RF-spoiled fast gradient-echo sequence (RF-FAST) acquired before and during passage of an intravenously administered bolus of Gd-DTPA. The images were subtracted and viewed as a cine loop. MR-DSA was performed successfully in all patients. High-flow lesions were shown in four patients; these included vein of Galen aneurysmal malformation, dural fistula, and two partially treated arteriovenous malformations (AVMs). Low-flow lesions were seen in three patients, all of which were tumours. Normal flow was confirmed in eight patients including two with successfully treated AVMs, and in three patients with cavernomas. Our early experience suggests that MR-DSA is a realistic, non-invasive alternative to catheter angiography in certain clinical settings. (orig.)

  20. A case of aortitis syndrome diagnosed by digital subtraction angiography

    International Nuclear Information System (INIS)

    Tamaki, Atsushi; Sakai, Masashi; Yano, Kimio

    1984-01-01

    A 45-year-old female was admitted to our hospital with complaints of anemia, hypertension, and a dull, throbbing pain in the right side of the neck. On physical examination, a pulsating tumor in the right side of the neck and a ''to-and-fro'' murmur at the right 2nd intercostal space were noted. Laboratory tests revealed ESR 90 mm/hour and CRP 5+. Digital subtraction angiography (DSA) showed an aneurysm distal to the narrowing of the right common carotid artery, in addition to winding and narrowing of the right vertebral and the left common carotid arteries. These findings are typical of Type I aortitis syndrome. Aortogram showed aortic regurgitation (AR). Furthermore, we found the presence of HLA Bw52 and a conspicuous increase of tromboxane B 2 . Treatment involving a combination of prednisolone, azathioprine and estriol was effective, resulting in marked improvement of the patient's general condition as well as laboratory test results. In cases of aortitis syndrome combined with an aneurysm of a large artery and AR, direct opacification of the aorta with a catheter is occasionally hazardous and is difficult to perform repeatedly. DSA is useful in such circumstances because it can be performed repeatedly with little risk and it offers an image as clear as these obtained by direct injection of contrast medium in the aorta. (author)

  1. Image noise reduction algorithm for digital subtraction angiography: clinical results.

    Science.gov (United States)

    Söderman, Michael; Holmin, Staffan; Andersson, Tommy; Palmgren, Charlotta; Babic, Draženko; Hoornaert, Bart

    2013-11-01

    To test the hypothesis that an image noise reduction algorithm designed for digital subtraction angiography (DSA) in interventional neuroradiology enables a reduction in the patient entrance dose by a factor of 4 while maintaining image quality. This clinical prospective study was approved by the local ethics committee, and all 20 adult patients provided informed consent. DSA was performed with the default reference DSA program, a quarter-dose DSA program with modified acquisition parameters (to reduce patient radiation dose exposure), and a real-time noise-reduction algorithm. Two consecutive biplane DSA data sets were acquired in each patient. The dose-area product (DAP) was calculated for each image and compared. A randomized, blinded, offline reading study was conducted to show noninferiority of the quarter-dose image sets. Overall, 40 samples per treatment group were necessary to acquire 80% power, which was calculated by using a one-sided α level of 2.5%. The mean DAP with the quarter-dose program was 25.3% ± 0.8 of that with the reference program. The median overall image quality scores with the reference program were 9, 13, and 12 for readers 1, 2, and 3, respectively. These scores increased slightly to 12, 15, and 12, respectively, with the quarter-dose program imaging chain. In DSA, a change in technique factors combined with a real-time noise-reduction algorithm will reduce the patient entrance dose by 75%, without a loss of image quality. RSNA, 2013

  2. Radiation doses to patients from digital subtraction angiography

    International Nuclear Information System (INIS)

    Goni, H.; Tsalafoutas, I. A.; Tzortzis, G.; Pappas, P.; Bouzas, N.; Loulakas, J.; Georgiou, A.; Georgiou, E.; Yakoumakis, E. N.

    2005-01-01

    This investigation determined patient doses during digital subtraction angiography (DSA). Fluoroscopy time, dose-area product (DAP) and entrance surface air kerma (ESAK) were analysed from 263 DSA examinations, classified into seven categories: (1) abdominal aorta, iliac, femoral, popliteal and leg arteries; (2) abdominal aorta and super-selective DSA of renal arteries; (3) combination of (1) and (2); (4) super-selective DSA of common carotid and vertebral arteries, intracranial branches in face and profile projections; (5) super-selective DSA of hepatic, splenic, superior and inferior mesenteric arteries; (6) combination of (1) and (4); and (7) celiac trunk and branches. Median DAP values were 67.7, 92.9, 76.6, 53.6, 105.7, 76.1 and 2.6 Gy cm 2 , respectively. With the exception of one examination, ESAK values were below 2 Gy: the limit for erythema. Compared with published data, DAP values were within the range reported for (1) and (4), slightly larger for (2) and (5), whereas no references were identified for the remaining three categories. (authors)

  3. Robotic digital subtraction angiography systems within the hybrid operating room.

    Science.gov (United States)

    Murayama, Yuichi; Irie, Koreaki; Saguchi, Takayuki; Ishibashi, Toshihiro; Ebara, Masaki; Nagashima, Hiroyasu; Isoshima, Akira; Arakawa, Hideki; Takao, Hiroyuki; Ohashi, Hiroki; Joki, Tatsuhiro; Kato, Masataka; Tani, Satoshi; Ikeuchi, Satoshi; Abe, Toshiaki

    2011-05-01

    Fully equipped high-end digital subtraction angiography (DSA) within the operating room (OR) environment has emerged as a new trend in the fields of neurosurgery and vascular surgery. To describe initial clinical experience with a robotic DSA system in the hybrid OR. A newly designed robotic DSA system (Artis zeego; Siemens AG, Forchheim, Germany) was installed in the hybrid OR. The system consists of a multiaxis robotic C arm and surgical OR table. In addition to conventional neuroendovascular procedures, the system was used as an intraoperative imaging tool for various neurosurgical procedures such as aneurysm clipping and spine instrumentation. Five hundred one neurosurgical procedures were successfully conducted in the hybrid OR with the robotic DSA. During surgical procedures such as aneurysm clipping and arteriovenous fistula treatment, intraoperative 2-/3-dimensional angiography and C-arm-based computed tomographic images (DynaCT) were easily performed without moving the OR table. Newly developed virtual navigation software (syngo iGuide; Siemens AG) can be used in frameless navigation and in access to deep-seated intracranial lesions or needle placement. This newly developed robotic DSA system provides safe and precise treatment in the fields of endovascular treatment and neurosurgery.

  4. Digital subtraction arthrography in preoperative evaluation of painful total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Ginai, A.Z. [Dept. of Radiology, Univ. Hospital Dijkzigt, Rotterdam (Netherlands); Biezen, F.C. van [Dept. of Orthopaedics, Univ. Hospital Dijkzigt and Erasmus Univ., Rotterdam (Netherlands); Kint, P.A.M. [Dept. of Radiology, Univ. Hospital Dijkzigt, Rotterdam (Netherlands); Oei, H.Y. [Dept. of Nuclear Medicine, Univ. Hospital Dijkzigt and Erasmus Univ., Rotterdam (Netherlands); Hop, W.C.J. [Dept. of Biostatistics, Univ. Hospital Dijkzigt and Erasmus Univ., Rotterdam (Netherlands)

    1996-05-01

    Digital subtraction arthrograms, scintigrams and plain radiographs of 70 consecutive patients who underwent revision hip arthroplasty were scored individually and in masked fashion for the presence or absence of features indicating loosening of femoral and/or acetabular components. The operative findings acted as the gold standard. Digital subtraction arthrography was best for predicting a loose acetabular component, while no significant additional predictive value was found for plain radiographs and scintigraphy. Digital subtraction arthrography was also the most important modality for predicting a loose femoral component, while the plain radiograph was of significant additional value and scintigraphy was of no additional value on multivariate analysis. (orig./MG)

  5. Digital subtraction arthrography in preoperative evaluation of painful total hip arthroplasty

    International Nuclear Information System (INIS)

    Ginai, A.Z.; Biezen, F.C. van; Kint, P.A.M.; Oei, H.Y.; Hop, W.C.J.

    1996-01-01

    Digital subtraction arthrograms, scintigrams and plain radiographs of 70 consecutive patients who underwent revision hip arthroplasty were scored individually and in masked fashion for the presence or absence of features indicating loosening of femoral and/or acetabular components. The operative findings acted as the gold standard. Digital subtraction arthrography was best for predicting a loose acetabular component, while no significant additional predictive value was found for plain radiographs and scintigraphy. Digital subtraction arthrography was also the most important modality for predicting a loose femoral component, while the plain radiograph was of significant additional value and scintigraphy was of no additional value on multivariate analysis. (orig./MG)

  6. Mental Computation or Standard Algorithm? Children's Strategy Choices on Multi-Digit Subtractions

    Science.gov (United States)

    Torbeyns, Joke; Verschaffel, Lieven

    2016-01-01

    This study analyzed children's use of mental computation strategies and the standard algorithm on multi-digit subtractions. Fifty-eight Flemish 4th graders of varying mathematical achievement level were individually offered subtractions that either stimulated the use of mental computation strategies or the standard algorithm in one choice and two…

  7. Digital subtraction radiographic evaluation of the standardize periapical intraoral radiographs

    International Nuclear Information System (INIS)

    Cho, Bong Hae; Nah, Kyung Soo

    1993-01-01

    The geometrically standardized intraoral radiographs using 5 occlusal registration material were taken serially from immediate, 1 day, 2, 4, 8, 12 and 16 weeks after making the bite blocks. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exaflex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  8. Proximal caries detection using digital subtraction radiography in the artificial caries activity model

    International Nuclear Information System (INIS)

    Park, Jong Hoon; Lee, Gi Ja; Choi, Sam Jin; Park, Young Ho; Kim, Kyung Soo; Jin, Hyun Seok; Hong, Kyung Won; Oh, Berm Seok; Park, Hun Kuk; Choi, Yong Suk; Hwang, Eui Hwan

    2009-01-01

    The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Digital radiographs of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size no.2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. In artificial caries activity model, the range of lesional depth was 572-1,374 μm and the range of lesional area was 36.95-138.52 mm 2 . The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  9. Proximal caries detection using digital subtraction radiography in the artificial caries activity model

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Hoon; Lee, Gi Ja; Choi, Sam Jin; Park, Young Ho; Kim, Kyung Soo; Jin, Hyun Seok; Hong, Kyung Won; Oh, Berm Seok; Park, Hun Kuk [Department of Biomedical Engineering, School of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Choi, Yong Suk; Hwang, Eui Hwan [Department of Oral and Maxillofacial Radiology, Institute of Oral Biology, School of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Digital radiographs of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size no.2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. In artificial caries activity model, the range of lesional depth was 572-1,374 {mu}m and the range of lesional area was 36.95-138.52 mm{sup 2}. The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  10. Imaging of the digital arteries: Digital subtraction angiography versus conventional angiography

    International Nuclear Information System (INIS)

    Menanteau, B.P.; Treutenaere, J.M.; Marcus, C.; Ladam, V.; Gausserand, F.

    1986-01-01

    The authors report their experience with the use of digital subtraction angiography (DSA) and conventional angiography of the hand. Of the 95 patients in the study group, 80 underwent conventional angiography and 15 underwent DSA. They analyzed the studies with regard to the type and amount of contrast agent used, the number of radiographs needed, and the diagnostic quality of the images. Conventional angiography often requires general anesthesia, magnification, and pharmaco-angiographic techniques to improve the image-based diagnosis. In comparison with conventional angiography, intraarterial DSA is characterized by improved contrast sensitivity and inferior spatial resolution. However, DSA provides images as acceptable as those of conventional angiography. Smaller catheters can be used, and the examination is performed under local anesthesia. The authors conclude that intraarterial DSA is now the technique of choice for examining patients with chronic ischemia of the hand

  11. Preliminary study of lateral cerebral angiography with reverse rotation in the digital image registration and subtraction

    International Nuclear Information System (INIS)

    Shen Zhenglin; Liu Dongyang; Shen Zhenghai; Li Shuping; Zhang Ziyan; Wu Yongjuan; Liu Peijun

    2012-01-01

    Objective: Investigate the value and feasibility of image registration with reverse rotation in lateral cerebral DSA. Methods: (1) Experimental study: the target images were subtracted directly, and subtracted again after reverse rotation. Software of registration and subtraction with reverse rotation edited by the author utilizing Visual Basic. The function of the automatic angle detection by the software were evaluated to see whether it detected the angle of line. The subtraction function of DSA by the software was evaluated. (2) Clinical retrospective study: the untreated mask and target images of 15 patients with motion along vertical axis during lateral cerebral DSA were uploaded to the software. The target images were processed with and without the software to get two sets of images. (3) Evaluation: four experienced radiologists read and compared the two sets of the images,and graded their findings. Results: (1) The automatic detection by the software suggested that the target images should be rotated counterclockwise 1.3°. The subtraction result of the software was satisfactory. (2) In the 15 sets of images, there were only three sets of images deemed optimal after traditional subtraction. After reverse rotation, artifacts were significantly reduced and the image sharper. There were ten cases with significant artifacts after traditional subtraction, and those images were sharper and showed more peripheral vessels after reverse rotation. The traditional subtraction images of two sets could not be interpreted,the reverse rotation registration images reached the diagnostic quality. (3) Subjective evaluation: there were more information and less noise and distortion in the registration images with reverse rotation than in the traditional subtraction. But the image resolution decreased slightly after reverse rotation registration. Conclusion: The registration of digital angiography with reverse rotation can improve the image quality in lateral cerebral DSA

  12. Role of digital tomosynthesis and dual energy subtraction digital radiography in detecting pulmonary nodules

    International Nuclear Information System (INIS)

    Kumar, Sarvana G.; Garg, Mandeep Kumar; Khandelwal, Niranjan; Gupta, Pankaj; Gupta, Dheeraj; Aggarwal, Ashutosh Nath; Bansal, Subash Chand

    2015-01-01

    Highlights: • Accuracy of digital tomosynthesis for nodule detection is substantially higher. • Improvement in diagnostic accuracy is most pronounced for nodules <10 mm. • There is five times increase in radiation dose compared to DR. - Abstract: Objective: Digital tomosynthesis (DT) and dual-energy subtraction digital radiography (DES-DR) are known to perform better than conventional radiography in the detection of pulmonary nodules. Yet the comparative diagnostic performances of DT, DES-DR and digital radiography (DR) is not known. The present study compares the diagnostic performances of DT, DES-DR and DR in detecting pulmonary nodules. Subjects and methods: The institutional Review Board approved the study and informed written consent was obtained. Fifty-five patients (30 with pulmonary nodules, 25 with non-nodular focal chest pathology) were included in the study. DT and DES-DR were performed within14 days of MDCT. Composite images acquired at high kVp as part of DES-DR were used as DR images. Images were analyzed for presence of nodules and calcification in nodules. Interpretations were assigned confidence levels from 1 to 5 according to Five-Point rating scale. Areas under the receiver operating characteristic curves were compared using Z test. Results: A total of 110 (88 non-calcified, 22 calcified) nodules were identified on MDCT. For detection of nodules, DR showed cumulative sensitivity and specificity of 25.45% and 67.97%, respectively. DT showed a cumulative sensitivity and specificity of 60.9% and 85.07%, respectively. The performance was significantly better than DR (p < 0.003). DES-DR showed sensitivity and specificity of 27.75% and 82.64%, not statistically different from those of DR (p—0.92). In detection of calcification, there was no statistically significant difference between DT, DES-DR and DR. Conclusions: DT performs significantly better than DES-DR and DR at the cost of moderate increase in radiation dose

  13. Application of digital subtraction angiography in disease of large cardiac vessel

    International Nuclear Information System (INIS)

    Arisawa, Jun; Sone, Shusuke; Morimoto, Shizuo; Ikezoe, Junpei; Higashibara, Tokuro; Hanayama, Masayuki

    1983-01-01

    Digital subtraction angiography (DSA) was performed in 31 cases of disease of large cardiac vessel. DSA was useful for the diagnosis of aortic aneurysm and malformation of large vessels, follow-up after A-C bypass operation and Blalock's shunt operation for tetralogy of Fallot and as an adjuvant modality in cardiac catheterization. (Chiba, N.)

  14. Application of digital subtraction angiography in disease of large cardiac vessel

    Energy Technology Data Exchange (ETDEWEB)

    Arisawa, Jun; Sone, Shusuke; Morimoto, Shizuo; Ikezoe, Junpei; Higashibara, Tokuro; Hanayama, Masayuki

    1983-06-01

    Digital subtraction angiography (DSA) was performed in 31 cases of disease of large cardiac vessel. DSA was useful for the diagnosis of aortic aneurysm and malformation of large vessels, follow-up after A-C bypass operation and Blalock's shunt operation for tetralogy of Fallot and as an adjuvant modality in cardiac catheterization.

  15. Digital subtraction angiography - a new approach to brain death determination in the newborn

    International Nuclear Information System (INIS)

    Albertini, A.; Schonfeld, S.; Hiatt, M.; Hegyi, T.

    1993-01-01

    The diagnosis of brain death in the newborn infants is elusive and often difficult. The lack of cerebral blood flow has become an identified criterion for loss of cerebral function. The diagnosis can be obtained by the technique of digital subtraction angiography, which is presented in two case reports demonstrating the utility of this technique. (orig.)

  16. Digital subtraction angiography and intraarterial contrast medium injection for coronary examinations

    Energy Technology Data Exchange (ETDEWEB)

    Tobio, R.; Kallmeyer, C.; Castello, J.

    1985-01-01

    Digital subtraction angiography (DSA) is an established method of vasography, most extensively used as i.v. DSA. Intraarterial injection, however, applying selective or non-selective contrast medium injection, seems to be at least as important a technique although it has not yet met with corresponding interest. The article explains advantages of the technique for angiographic examinations, in particular of coronary angiography.

  17. Digital image comparison by subtracting contextual transformations—percentile rank order differentiation

    Science.gov (United States)

    Wehde, M. E.

    1995-01-01

    The common method of digital image comparison by subtraction imposes various constraints on the image contents. Precise registration of images is required to assure proper evaluation of surface locations. The attribute being measured and the calibration and scaling of the sensor are also important to the validity and interpretability of the subtraction result. Influences of sensor gains and offsets complicate the subtraction process. The presence of any uniform systematic transformation component in one of two images to be compared distorts the subtraction results and requires analyst intervention to interpret or remove it. A new technique has been developed to overcome these constraints. Images to be compared are first transformed using the cumulative relative frequency as a transfer function. The transformed images represent the contextual relationship of each surface location with respect to all others within the image. The process of differentiating between the transformed images results in a percentile rank ordered difference. This process produces consistent terrain-change information even when the above requirements necessary for subtraction are relaxed. This technique may be valuable to an appropriately designed hierarchical terrain-monitoring methodology because it does not require human participation in the process.

  18. Evaluation of coronary blood flow using digital subtraction technique and cine coronary angiography

    International Nuclear Information System (INIS)

    Uwatoko, Masashi; Miyagi, Yutaka; Nomura, Masanori

    1988-01-01

    To evaluate coronary circulation in ischemic heart disease, digital image processing with cine coronary angiography was performed. Using time-density curves obtained from individual pixels, images showing the distribution of contrast density and transit time were obtained. To record angiograms, contrast medium was injected into the coronary artery in a steady manner during right atrial pacing. Frames in the end-diastolic phase immediately before the P wave were selected, and digitized into a 512 x 512 x 8 bit matrix using a system composed of a video camera, an analog-to-digital converter, and a computer. These digitized images were then stored in a disk memory. A mask image was prepared before the injection of contrast medium. Subtraction was performed using the mask image and a series of images following contrast injection. The subtracted images were of sufficient quality to permit clear observation of the individual coronary arterial branches. Time-density curves were then determined from these subtracted images. From these curves, time from the onset of contrast injection to its peak density (Tp), time from the peak density to the half peak density (T1/2) and the attenuation factor of the curves (τ) were derived. Their distributions were expressed as color images. Examples of normal control and a case of inferior infarction were demonstrated. Blood flow function images with good spatial resolution were thus obtained. This method is useful for evaluating coronary blood flow. (author)

  19. Intraarterial digital subtraction angiography in bronchogenic carcinoma treated with bronchial artery infusion

    International Nuclear Information System (INIS)

    Gao-Jun Teng; Xi-Lei Chai; Guang-Ru Gao; Cheng-Fong Chu; Xian-Guang Zhou; Zhu-Yi Zhang; Ru-Li Xiang

    1991-01-01

    Intra-arterial digital subtraction angiography (IADSA) has been used with advantage for control of the results of bronchial artery infusion of drugs for primarily unresectable bronchogenic carcinoma. The IADSA has been performed as road mapping prior to therapy. Drug treatment has been performed with 4 different regimes, depending on tumour type. Debulking and in some cases complete healing are the results, which are superior to other reported treatments. (author). 7 refs.; 4 figs.; 3 tabs

  20. Deep vein thrombosis of the upper extremity: intra- and interobserver study of digital subtraction venography

    Energy Technology Data Exchange (ETDEWEB)

    Baarslag, Henk J.; Delden, Otto M. van; Bakker, Ad J.; Reekers, Jim A. [Department of Radiology, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Beek, Edwin J.R. van [Department of Radiology, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Section of Academic Radiology, Floor C, Royal Hallamshire Hospital, Glossop Road, Sheffield S10 2JF (United Kingdom); Tijssen, Jan G.P. [Department of Cardiology, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands)

    2003-02-01

    Our objective was to assess the inter-observer and intra-observer agreement in the interpretation of digital subtraction venography (DSV) in patients with suspected deep vein thrombosis of the upper extremity (DVTUE). Prospectively, 62 consecutive DSV studies in 54 patients with clinically suspected DVTUE were included. Hard copies were presented without demographic data or original report. All venograms were read twice, at 3-month intervals, by an interventional vascular radiologist (observer 1) and an experienced general radiologist (observer 2). Consensus reading took place in the presence of a third experienced interventional radiologist. Inter-observer and intra-observer agreement were assessed using kappa statistics. Initial reading in 62 venograms showed an inter-observer agreement of 71% (kappa 0.48). The inter-observer agreement of the second reading was 83% (kappa 0.71). The agreement with the consensus report ranged from 76 to 94%. The intra-observer agreement for the first and second observer was 94% (kappa 0.89) and 76% (kappa 0.56), respectively (p<0.01). Digital subtraction venography has moderate to excellent intra- and inter-observer agreement, suggesting that digital subtraction venography is reliable for the diagnosis of DVTUE. (orig.)

  1. Digital subtraction radiography evaluation of longitudinal bone density changes around immediate loading implants: a pilot study.

    Science.gov (United States)

    Carneiro, L S; da Cunha, H A; Leles, C R; Mendonça, E F

    2012-03-01

    The aim of this study was to assess longitudinal quantitative changes in bone density around different implant loading protocols and implant surfaces measured by digital subtraction radiography (DSR). 12 patients received bilateral homologous standard and TiUnite® (Nobel Biocare, Kloten, Switzerland) single-tooth implants under 2 implant-loading protocols: immediate loading (8 patients, 16 implants, 12 maxillary) and conventional loading (4 patients, 8 implants, 4 maxillary). Standardized periapical radiographs were taken immediately after implant placement (baseline image) and at the 3-month, 6-month and 12-month follow ups. Radiographic images were digitized and submitted to digital subtraction using the DSR system® (Electro Medical System, Nyon, Switzerland), resulting in three subtracted images. Quantitative analysis of bone density was performed using Image Tool® software (University of Texas Health Science Centre, San Antonio, TX) to assess pixel value changes in five areas around the implants (crestal, subcrestal, medial third, apical-lateral and apical). Repeated-measures analysis of variance showed that grey levels were significantly influenced by follow-up time and implant-loading protocol. A linear increase in grey levels was found for immediate loading (IML) implants and a significant decrease in grey levels was observed in the 12-month follow up for conventional loading implants. No effect of implant surface treatment was observed. In conclusion, IML protocol induced mineral bone gain around single-tooth implants after the first year under function for cases with favourable bone conditions.

  2. Dissociated brain organization for two-digit addition and subtraction: an fMRI investigation.

    Science.gov (United States)

    Yi-Rong, Ni; Si-Yun, Shu; Zhou-Yi, Guo; Si-Run, Liu; Yun, Bao; Song-Hao, Liu; Chan, Wood Yee

    2011-11-25

    The present study compared the patterns of brain activation elicited by two-digit addition and subtraction problems. Thirty-two Chinese undergraduates of the same educational background and of similar age were asked to assess whether arithmetic operations were true or false during functional magnetic resonance imaging. Results showed that both complex addition and subtraction were supported by the broad neural system that involved regions within the inferior parietal lobule, the precuneus, and the inferior occipital gyrus, as well as some subcortical structures. Nevertheless, complex problems involving addition elicited more activation mainly in the bilateral medial frontal gyrus, whereas problems involving subtraction had more activation in the precentral gyrus and the thalamus in the right hemisphere, as well as the inferior parietal lobule in the left hemisphere. This pattern of dissociated activation suggests that partially separate neuronal networks might support these different operations. It also suggests that complex addition has a greater reliance on the fronto-parietal cortical circuit and subtraction on the parieto-subcortical circuit. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Image processing of images from peripheral-artery digital subtraction angiography (DSA) studies

    International Nuclear Information System (INIS)

    Wilson, D.L.; Tarbox, L.R.; Cist, D.B.; Faul, D.D.

    1988-01-01

    A system is being developed to test the possibility of doing peripheral, digital subtraction angiography (DSA) with a single contrast injection using a moving gantry system. Given repositioning errors that occur between the mask and contrast-containing images, factors affecting the success of subtractions following image registration have been investigated theoretically and experimentally. For a 1 mm gantry displacement, parallax and geometric image distortion (pin-cushion) both give subtraction errors following registration that are approximately 25% of the error resulting from no registration. Image processing techniques improve the subtractions. The geometric distortion effect is reduced using a piece-wise, 8 parameter unwarping method. Plots of image similarity measures versus pixel shift are well behaved and well fit by parabola, leading to the development of an iterative, automatic registration algorithm that uses parabolic prediction of the new minimum. The registration algorithm converges quickly (less than 1 second on a MicroVAX) and is relatively immune to the region of interest (ROI) selected

  4. Bone marrow edema pattern identification in patients with lytic bone lesions using digital subtraction angiography-like bone subtraction on large-area detector computed tomography.

    Science.gov (United States)

    Gondim Teixeira, Pedro Augusto; Hossu, Gabriela; Lecocq, Sophie; Razeto, Marco; Louis, Matthias; Blum, Alain

    2014-03-01

    The objective of this study was to evaluate the performance of digital subtraction angiography (DSA)-like bone subtraction with 2 different registration methods for the identification of bone marrow edema pattern (BMEP) in patients with lytic bone lesions, using magnetic resonance imaging as the criterion standard. Fifty-five patients with a lytic bone lesion were included in this prospective study with approval from the ethics committee. All patients underwent magnetic resonance imaging and low-dose computed tomographic (CT) perfusion after signing an informed consent. Two CT volumes were used for bone subtraction, which was performed with 2 different algorithms (rigid and nonrigid). Enhancement at the nonlytic bone marrow was considered as a sign of BMEP. Two readers evaluated the images blindly. The presence of BMEP on bone-subtracted CT images was evaluated subjectively and quantitatively. Image quality was assessed. Magnetic resonance imaging was used as the criterion standard. Using a rigid registration method, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CT with DSA-like bone subtraction BMEP was 77%, 100%, 100%, 68%, and 85%, respectively. The interobserver agreement was good (κ, 0.782). Image quality was better using a nonrigid registration. With this algorithm, artifacts interfered with image interpretation in only 5% of cases. However, there was a noticeable drop in sensitivity and negative predictive value when a nonrigid algorithm was used: 56% and 52%, respectively. The interobserver agreement was average with a nonrigid subtraction algorithm. Computed tomography with DSA-like bone subtraction is sensitive and highly specific for the identification of BMEP associated with lytic bone lesions. Rigid registering should be preferred, but nonrigid algorithms can be used as a second option when artifacts interfere with image interpretation.

  5. Reproducibility of and file format effect on digital subtraction radiography of simulated external root resorptions.

    Science.gov (United States)

    Gegler, A; Mahl, Cew; Fontanella, V

    2006-01-01

    To evaluate, in simulated external root resorptions (ERR), two factors that may affect results of digital subtraction radiography (DSR): (1) intraobserver and interobserver reproducibility and (2) effects of digital file formats (TIFF, BMP and JPEG) on the estimation of mineral loss. Eleven incisors were radiographed three times (NR, no resorption; SR, small--#1/4 round bur; and LR, large--#2 round bur) on standardized projections. The resulting images were reproduced and saved as TIFF, JPEG and BMP file formats. The pairs of TIFF images (NR x SR and NR x LR) were subtracted three times at 1 week intervals by three observers. One observer subtracted pairs of images (NR x SR and NR x LR) for all file formats. For each subtraction the resorption area was selected and mean pixel density values were calculated. Analysis of variance (ANOVA) (P = 0.05) showed no statistical differences for intraobserver and interobserver values. Mean pixel density values were: observer A, 121.60 +/- 2.56 (NR x SR) and 111.84 +/- 4.04 (NR x LR); observer B, 121.86 +/- 2.50 (NR x SR) and 110.92 +/- 3.36 (NR x LR); and observer C, 121.70 +/- 2.39 (NR x SR) and 111.10 +/- 2.67 (NR x LR). Also, no statistical differences were found between file formats for LR (TIFF, 110.88 +/- 2.79; JPEG, 111.35 +/- 3.35; BMP, 111.00 +/- 2.70) and for SR between TIFF (121.30 +/- 2.34) and JPEG (120.46 +/- 1.51) or BMP (121.67 +/- 2.18) file formats. Differences were found between the JPEG and BMP groups. DSR is reproducible in simulated ERR, and JPEG or BMP file formats do not affect results.

  6. Accuracy of digital subtraction radiography in combination with a contrast media in assessment of proximal caries depth

    Directory of Open Access Journals (Sweden)

    Farzad Esmaeili

    2008-07-01

    Full Text Available Background and aims. Radiography is used to diagnose the demineralization process and carious lesions; however, conventional radiography and direct digital images do not show these lesions when the amount of demineralization is less than 40%. Digital subtraction radiography has recently been used to improve the diagnostic quality of these lesions. The purpose of this study was to compare the caries depth estimated by digital subtraction radiography in combination with barium sulfate in diagnosing proximal dental caries with histopathologic evaluation. Materials and methods. In this study 30 molars and premolars (24 demineralized lesions with cavity, 8 without cavity were studied. Direct digital images were taken (kVp: 68, mA: 8; t: 0.12 for premolars and t: 0.16 for molars whereas the position of X-ray tube and CCD receptor and teeth was fixed. To prepare the second images 135 gr/L barium sulfate was used. The images obtained with the same exposure and geometry and then subtracted. The depth of the lesions in direct digital and subtracted images were assessed and compared with the depth measured in histopathologic assessments. Results. The mean depths (± SD of the lesions were 1.80 ± 0.77 mm in direct digital radiography, 2.32 ± 0.76 mm in subtracted images after barium sulfate treatment, and 2.51 ± 0.43 mm in histopathologic sections. The statistical difference between direct digital radiography and the other methods was significant (P < 0.05. However, the differences were not statistically significant between subtracted images and histopathologic sections. The average intra-class correlation coefficient was 0.7241 (CI: 95%. Conclusion. The present study has demonstrated that digital subtraction radiography images have the potential to measure the depth of proximal caries with no significant difference with histopathologic evaluation.

  7. Digital Subtraction Phonocardiography (DSP applied to the detection and characterization of heart murmurs

    Directory of Open Access Journals (Sweden)

    Ali Akbari Mohammad

    2011-12-01

    Full Text Available Abstract Background During the cardiac cycle, the heart normally produces repeatable physiological sounds. However, under pathologic conditions, such as with heart valve stenosis or a ventricular septal defect, blood flow turbulence leads to the production of additional sounds, called murmurs. Murmurs are random in nature, while the underlying heart sounds are not (being deterministic. Innovation We show that a new analytical technique, which we call Digital Subtraction Phonocardiography (DSP, can be used to separate the random murmur component of the phonocardiogram from the underlying deterministic heart sounds. Methods We digitally recorded the phonocardiogram from the anterior chest wall in 60 infants and adults using a high-speed USB interface and the program Gold Wave http://www.goldwave.com. The recordings included individuals with cardiac structural disease as well as recordings from normal individuals and from individuals with innocent heart murmurs. Digital Subtraction Analysis of the signal was performed using a custom computer program called Murmurgram. In essence, this program subtracts the recorded sound from two adjacent cardiac cycles to produce a difference signal, herein called a "murmurgram". Other software used included Spectrogram (Version 16, GoldWave (Version 5.55 as well as custom MATLAB code. Results Our preliminary data is presented as a series of eight cases. These cases show how advanced signal processing techniques can be used to separate heart sounds from murmurs. Note that these results are preliminary in that normal ranges for obtained test results have not yet been established. Conclusions Cardiac murmurs can be separated from underlying deterministic heart sounds using DSP. DSP has the potential to become a reliable and economical new diagnostic approach to screening for structural heart disease. However, DSP must be further evaluated in a large series of patients with well-characterized pathology to determine

  8. Assessment of maximal myocardial perfusion by ECG-triggered digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Pijls, N.H.J.; Uijen, G.J.H.; Werf, T. van der (Katholieke Univ. Nijmegen (Netherlands). Cardiology Dept.)

    1991-01-01

    Early studies about calculation of coronary blood flow by analysis of contrast agent passage on the coronary arteriogram were reported more than 2 decades ago by Rutishauser et al. and Smith et al. Thereafter is was shown that visualization of contrast passage through the myocardium could be enhanced by ECG-triggered digital subtraction imaging and it was suggested that myocardial flow could be calculated by studying the temporal changes in contrast intensity in a myocardial region of interest (ROI) as a function of time: the time density curve (TDC). (orig./GDG).

  9. Advantages and limitation of intra-arterial digital subtraction angiography (i.a. DSA)

    International Nuclear Information System (INIS)

    Beduhn, D.

    1986-01-01

    Among 3000 digital subtraction angiographies which have been performed in our institute, 850 patients have been examined intraarterially. The advantage of i.a. DSA is due to the excellent demonstration of vessels in survey angiograms by small amounts of contrast medium (10-20 ml in the aorta), without risk of selective catheterisation into the neck vessels, the saving of expensive film series, the short duration of vessel examinations and the small complication rate. i.a. DSA can be carried out on outpatients also, using the 4/5 F-catheter, which saves hospital charges. Impressive examples show the advantages of i.a. DSA. (orig.) [de

  10. Improved artifact rejection and isolation of compound action potentials by means of digital subtraction.

    Science.gov (United States)

    Kiss, I; Shizgal, P

    1989-12-01

    When recording compound action potentials (CAPs) elicited by stimulating near the recording site, it may prove difficult to distinguish the CAP from the shock artifact because of their overlap in time. This problem is compounded when a pair of stimulation pulses is delivered because the CAP elicited by the test pulse (T pulse) may be partially superimposed on the artifact and response elicited by the conditioning pulse (C pulse) as well as on the T pulse artifact. Methods based on digital subtraction were used to address these problems. A record was obtained with the C-T interval adjusted to be slightly less than the absolute refractory period so that the T pulse would fail to elicit a CAP. A record consisting of a C pulse artifact and response was subtracted from this record to yield a 'pure' shock artifact. In principle, subtracting this 'artifact-only' record from records obtained with single pulses removes the shock artifact and yields a 'pure' response. An extension of this method was used to isolate T pulse responses from the C pulse artifact, C pulse response, and T pulse artifact. These methods proved effective in improving the isolation of the CAPs of interest from other features of the raw records. Limitations of the techniques and their complementarity with other methods of artifact reduction are discussed.

  11. Role of digital tomosynthesis and dual energy subtraction digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Sharma, Madhurima; Sandhu, Manavjit Singh; Gorsi, Ujjwal; Gupta, Dheeraj; Khandelwal, Niranjan

    2015-01-01

    Highlights: • Digital tomosynthesis and dual energy subtraction digital radiography are modifications of digital radiography. • These modalities perform better than digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis. • Digital tomosynthesis has a sensitivity of 100% in detection of cavities. • Centrilobular nodules seen on CT in active pulmonary tuberculosis, were also demonstrated on digital tomosynthesis in our study. • Digital tomosynthesis can be used for diagnosis and follow up of patients in pulmonary tuberculosis, thereby reducing the number of CT examinations. - Abstract: Objective: To assess the role of digital tomosynthesis (DTS) and dual energy subtraction digital radiography (DES-DR) in detection of parenchymal lesions in active pulmonary tuberculosis (TB) and to compare them with digital radiography (DR). Materials and methods: This prospective study was approved by our institutional review committee. DTS and DES-DR were performed in 62 patients with active pulmonary TB within one week of multidetector computed tomography (MDCT) study. Findings of active pulmonary TB, that is consolidation, cavitation and nodules were noted on digital radiography (DR), DTS and DES-DR in all patients. Sensitivity, specificity, positive and negative predictive values of all 3 modalities was calculated with MDCT as reference standard. In addition presence of centrilobular nodules was also noted on DTS. Results: Our study comprised of 62 patients (33 males, 29 females with age range 18–82 years). Sensitivity and specificity of DTS for detection of nodules and cavitation was better than DR and DES-DR. Sensitivity and specificity of DTS for detection of consolidation was comparable to DR and DES-DR. DES-DR performed better than DR in detection of nodules and cavitation. DTS was also able to detect centrilobular nodules with sensitivity and specificity of 57.4% and 86.5% respectively. Conclusion: DTS and DES-DR perform better

  12. Role of digital tomosynthesis and dual energy subtraction digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Madhurima, E-mail: madhurimashrm88@gmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Sandhu, Manavjit Singh, E-mail: manavjitsandhu@yahoo.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Gorsi, Ujjwal, E-mail: ujjwalgorsi@gmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Gupta, Dheeraj, E-mail: dheeraj1910@gmail.com [Department of Pulmonary Medicine, PGIMER, Chandigarh 160012 (India); Khandelwal, Niranjan, E-mail: khandelwaln@hotmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India)

    2015-09-15

    Highlights: • Digital tomosynthesis and dual energy subtraction digital radiography are modifications of digital radiography. • These modalities perform better than digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis. • Digital tomosynthesis has a sensitivity of 100% in detection of cavities. • Centrilobular nodules seen on CT in active pulmonary tuberculosis, were also demonstrated on digital tomosynthesis in our study. • Digital tomosynthesis can be used for diagnosis and follow up of patients in pulmonary tuberculosis, thereby reducing the number of CT examinations. - Abstract: Objective: To assess the role of digital tomosynthesis (DTS) and dual energy subtraction digital radiography (DES-DR) in detection of parenchymal lesions in active pulmonary tuberculosis (TB) and to compare them with digital radiography (DR). Materials and methods: This prospective study was approved by our institutional review committee. DTS and DES-DR were performed in 62 patients with active pulmonary TB within one week of multidetector computed tomography (MDCT) study. Findings of active pulmonary TB, that is consolidation, cavitation and nodules were noted on digital radiography (DR), DTS and DES-DR in all patients. Sensitivity, specificity, positive and negative predictive values of all 3 modalities was calculated with MDCT as reference standard. In addition presence of centrilobular nodules was also noted on DTS. Results: Our study comprised of 62 patients (33 males, 29 females with age range 18–82 years). Sensitivity and specificity of DTS for detection of nodules and cavitation was better than DR and DES-DR. Sensitivity and specificity of DTS for detection of consolidation was comparable to DR and DES-DR. DES-DR performed better than DR in detection of nodules and cavitation. DTS was also able to detect centrilobular nodules with sensitivity and specificity of 57.4% and 86.5% respectively. Conclusion: DTS and DES-DR perform better

  13. Evaluation of Bone Change by Digital Subtraction Radiography After Implantation of Tooth ash-plaster Mixture

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Duk; Kim, Kwang Won; Cho, Young Gon; Kim, Dong Kie; Choi, Eui Hwan [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Chosun University and Oral Biology Research Center, Kwangju (Korea, Republic of)

    1999-08-15

    To assess the methods for the clinical evaluation of the longitudinal bone changes after implantation of tooth ash-plaster mixture into the defect area of human jaws. Tooth ash-plaster mixtures were implanted into the defects of 8 human jaws. 48 intraoral radiograms taken with copper step wedge as reference at soon, 1st, 2nd, 4th, and 6th week after implantation of mixture were used. X-ray taking was standardized by using Rinn XCP device customized directly to the individual dentition with resin bite block. The images inputted by Quick scanner were digitized and analyzed by NIH image program. Cu-equivalent values were measured at the implanted sites from the periodic digital images. Analysis was performed by the bidirectional subtraction with color enhancement and the surface plot of resliced contiguous image. The obtained results by the two methods were compared with Cu-equivalent value changes. The average determination coefficient of Cu-equivalent equations was 0.9988 and the coefficient of variation of measured Cu values ranged from 0.08-0.10. The coefficient of variation of Cu-equivalent values measured at the areas of the mixture and the bone by the conversion equation ranged from 0.06-0.09. The analyzed results by the bidirectional subtraction with color enhancement were coincident with the changes of Cu-equivalent values. The surface plot of the resliced contiguous image showed the three dimensional view of the longitudinal bone changes on one image and also coincident with Cu-equivalent value changes after implantation. The bidirectional subtraction with color enhancement and the surface plot of the resliced contiguous image was very effective and reasonable to analyze clinically and qualitatively the longitudinal bone change. These methods are expected to be applicable to the non-destructive test in other fields.

  14. Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography

    Directory of Open Access Journals (Sweden)

    Wilton Mitsunari Takeshita

    2013-01-01

    Full Text Available Background: To compare the diagnostic accuracy of three different imaging systems: Direct digital radiography system (DDR-CMOS, four types of filtered images, and a priori and a posteriori registration of digital subtraction radiography (DSR in the diagnosis of proximal defects. Materials and Methods: The teeth were arranged in pairs in 10 blocks of vinyl polysiloxane, and proximal defects were performed with drills of 0.25, 0.5, and 1 mm diameter. Kodak RVG 6100 sensor was used to capture the images. A posteriori DSR registrations were done with Regeemy 0.2.43 and subtraction with Image Tool 3.0. Filtered images were obtained with Kodak Dental Imaging 6.1 software. Images (n = 360 were evaluated by three raters, all experts in dental radiology. Results: Sensitivity and specificity of the area under the receiver operator characteristic (ROC curve (Az were higher for DSR images with all three drills (Az = 0.896, 0.979, and 1.000 for drills 0.25, 0.5, and 1 mm, respectively. The highest values were found for 1-mm drills and the lowest for 0.25-mm drills, with negative filter having the lowest values of all (Az = 0.631. Conclusion: The best method of diagnosis was by using a DSR. The negative filter obtained the worst results. Larger drills showed the highest sensitivity and specificity values of the area under the ROC curve.

  15. Large renal angiomyolipomas: digital subtraction angiographic grading and presentation with bleeding

    International Nuclear Information System (INIS)

    Rimon, U.; Duvdevani, M.; Garniek, A.; Golan, G.; Bensaid, P.; Ramon, J.; Morag, B.

    2006-01-01

    AIM: To investigate whether a grading system of renal AMLs based on digital subtraction angiography (DSA) and computerized tomography (CT), could help to select patients for embolization. MATERIALS AND METHODS: Thirty patients with 35 renal angiomyolipomas (size range 4-20cm, mean 9.9cm) underwent both digital subtraction angiography (DSA) and computed tomography (CT). Based on the DSA appearance the tumours were graded into three grades: grade I, minimal vascularity; grade II, moderate vascularity; grade III, marked vascularity. RESULTS: There were seven grade I (mean 9.3cm, range 4.5-20cm), 18 grade II (mean 8.9cm, range 5-18cm) and 10 grade III tumours (mean 12.1cm, range 4-20cm). Five grade I tumours did not cause symptoms (71%) and two caused flank pain and haematuria, respectively (14.3% each). Nine of the grade II tumours were asymptomatic (50%), seven caused bleeding (39%) and two caused flank pain (11%). Four grade III tumours were asymptomatic (40%), five caused bleeding (50%) and one pain (10%). CONCLUSIONS: According to our criteria, large angiomyolipomas with minimal vascularity are less likely to bleed, and do not need prophylactic treatment. This needs to be confirmed in larger studies

  16. The reduction of motion artifacts in digital subtraction angiography by geometrical image transformation

    International Nuclear Information System (INIS)

    Fitzpatrick, J.M.; Pickens, D.R.; Mandava, V.R.; Grefenstette, J.J.

    1988-01-01

    In the diagnosis of arteriosclerosis, radio-opaque dye is injected into the interior of the arteries to make them visible. Because of its increased contrast sensitivity, digital subtraction angiography has the potential for providing diagnostic images of arteries with reduced dye volumes. In the conventional technique, a mask image, acquired before the introduction of the dye, is subtracted from the contrast image, acquired after the dye is introduced, to produce a difference image in which only the dye in the arteries is visible. The usefulness of this technique has been severely limited by the image degradation caused by patient motion during image acquisition. This motion produces artifacts in the difference image that obscure the arteries. One technique for dealing with the problem is to reduce the degradation by means of image registration. The registration is carried out by means of a geometrical transformation of the mask image before subtraction so that it is in registration with the contrast image. This paper describes a technique for determining an optimal transformation. The authors employ a one-to-one elastic mapping and the Jacobian of that mapping to produce a geometrical image transformation. They choose a parameterized class of such mappings and use a heuristic search algorithm to optimize the parameters to minimize the severity of the motion artifacts. To increase the speed of the optimization process they use a statistical image comparison technique that provides a quick approximate evaluation of each image transformation. They present the experimental results of the application of their registration system to mask-contrast pairs, for images acquired from a specially designed phantom, and for clinical images

  17. Intraarterial digital subtraction angiography after plastic surgery by thin-needle puncture

    Energy Technology Data Exchange (ETDEWEB)

    Langer, M.; Fiegler, W.; Claussen, C.; Koehler, D.; Felix, R.; Hepp, W.

    1984-06-01

    Over the period of a year (1983), 44 intraarterial digital subtraction angiographies (DSA) via direct thin-needle puncture of a vascular bypass or following vascular graft were carried the rough. The only complication that occurred: paravasal injection, was clinically insignificant and could be avoided by a change in the puncture-technique. It was possible to carry through the investigation in out-patients. In all cases, diagnostically useful picture material for a possible surgical intervention was obtained. The pictures always were high-grade, independently of the patient's circulation time. Because this is a simple investigation and because of the small risk of complications, it has come to be regularly carried through as a routine in the authors' clinic. According to investigations carried through on the collective of patients of a vascular surgery department, occlusions or anastomotic aneurismus account for most of the angiological disorders.

  18. Intraarterial digital subtraction angiography after plastic surgery by thin-needle puncture

    International Nuclear Information System (INIS)

    Langer, M.; Fiegler, W.; Claussen, C.; Koehler, D.; Felix, R.; Hepp, W.

    1984-01-01

    Over the period of a year (1983), 44 intraarterial digital subtraction angiographies (DSA) via direct thin-needle puncture of a vascular bypass or following vascular graft were carried the rough. The only complication that occured: paravasal injection, was clinically insignificant and could be avoided by a change in the puncture-technique. It was possible to carry through the investigation in out-patients. In all cases, diagnostically useful picture material for a possible surgical intervention was obtained. The pictures always were high-grade, independently of the patient's circulation time. Because this is a simple investigation and because of the small risk of complications, it has come to be regularly carried through as a routine in the authors' clinic. According to investigations carried through on the collective of patients of a vascular surgery department, occlusions or anastomotic aneurismus account for most of the angiological disorders. (orig.) [de

  19. Digital subtraction angiography of lower limb arteries using and automatic table translation. Feasibility. Preliminary results

    International Nuclear Information System (INIS)

    Seka, R.; Amiel, M.; Boller, A.; Chapelon, C.; Clermont, A.; Revel, D.; Pinet, F.

    1988-01-01

    Digital subtraction angiography (DSA) as a method of evaluating lower limb arteries required examination of one limb at a time up to now. Moreover repeated injections of contrast material were necessary. This problem was mainly due to the relative small image intensifier field available and to the difficulty of repositionning the patient between mask and image acquisition. The preliminary results obtained with 24 patients studied on angiographic unit equipped with: a DSA system (DG 300-CGR) using 512x512 matrix size, an angiographic table (Angix M 200) allowing an automatic sequantial translation, a removable image intensifier using a 16 inch field below the table, are reported. Thus, all those characteristics allow DSA of lower limb arteries. Only one injection of contrast material (Ioxaglate: 80 ml at 8-10 ml/second) was used per procedure. This, usually, allows good quality examination of lower limb arteries [fr

  20. Idiopathic Thrombus in the Common Carotid Artery on Digital Subtraction Angiography

    Directory of Open Access Journals (Sweden)

    Anand Alurkar

    2012-01-01

    Full Text Available In the present study, we discuss the accuracy of digital subtraction angiography (DSA in diagnosis of thrombus in the common carotid artery and its role in the medical management of this disorder. Between 2006 and 2011, four patients (age group ranging from 26 to 48 years presented to our institution with symptoms of stroke. DSA in all these patients showed cigar-shaped filling defect in the common carotid artery. All the patients were managed successfully with anticoagulation treatment. Follow-up Duplex scan was done in all the patients. DSA is the gold standard to diagnose free floating thrombus in the common carotid artery. Medical management can be effective in these patients but a multidisciplinary team approach is needed for appropriate management.

  1. Evaluation of the superior vena cava system in children with digital subtraction angiography

    International Nuclear Information System (INIS)

    Pariente, D.; Lacombe, P.

    1986-01-01

    The authors report a new pediatric application of digital subtraction angiography (DSA) that is the evaluation of the superior vena cava system. 22 children have been explored. All of them had a history of previous central venous catheter placement for parenteral nutrition (13), hemodialysis (5), chemotherapy or antibiotic therapy (4). The aim of the examination was to obtain a venous mapping before a new catheter placement (14 cases) or to look for a venous thrombosis origin of superior vena cava syndrom or septicemia (8 cases). Except failure of two examinations because of absence of venous injection site, DSA showed thrombosis of one vein in 7 cases and of multiple veins in 11 cases. A pulmonary embolus was also discovered. The authors conclude that this non invasive method yields very valuable information on superior vena cava system [fr

  2. [Affine transformation-based automatic registration for peripheral digital subtraction angiography (DSA)].

    Science.gov (United States)

    Kong, Gang; Dai, Dao-Qing; Zou, Lu-Min

    2008-07-01

    In order to remove the artifacts of peripheral digital subtraction angiography (DSA), an affine transformation-based automatic image registration algorithm is introduced here. The whole process is described as follows: First, rectangle feature templates are constructed with their centers of the extracted Harris corners in the mask, and motion vectors of the central feature points are estimated using template matching technology with the similarity measure of maximum histogram energy. And then the optimal parameters of the affine transformation are calculated with the matrix singular value decomposition (SVD) method. Finally, bilinear intensity interpolation is taken to the mask according to the specific affine transformation. More than 30 peripheral DSA registrations are performed with the presented algorithm, and as the result, moving artifacts of the images are removed with sub-pixel precision, and the time consumption is less enough to satisfy the clinical requirements. Experimental results show the efficiency and robustness of the algorithm.

  3. Combined use of intraarterial digital subtraction angiography with conventional retrograde brachial vertebral angiography

    International Nuclear Information System (INIS)

    Yamaguchi, Tatsuo; Ogawa, Toshihide; Inugami, Atsushi; Kawata, Yasushi; Shishido, Fumio; Uemura, Kazuo

    1985-01-01

    For 102 patients who had the examination of conventional bilaterally retrograde brachial vertebral angiography (retrograde VAG), intraarterial digital subtraction angiography (DSA) was successively performed to investigate steno-occlusive lesions of proximal vertebral and subclavian arteries. All the patients had no complication due to the DSA procedure. In 50% of 72 ischemic stroke cases, positive findings were found either in the origin of the vertebral artery or in the subclavian artery. Stenosis of more than 50% of the lumen of the vertebral artery were found in 14% of the cases at the origin of the right one and also in 14% in the left one. Occlusion of the vertebral artery was found in 4% in the left side only. In 30 cases with non-ischemic brain diseases, positive findings were noted in 10%. Intraarterial DSA combined with retrograde VAG was thought to be useful, especially in the examination for ischemic stroke. (author)

  4. Digital subtraction angiography of inferior gluteal artery through the infusion catheter of chemotherapy for bladder cancer

    International Nuclear Information System (INIS)

    Ishikawa, Satoru; Noguchi, Ryosuke; Kanoh, Shori; Shimazui, Toru; Uchida, Katsunori; Nemoto, Ryosuke; Koiso, Kenkichi

    1987-01-01

    More than fifty patients of invasive bladder cancer had been treated by selective intra-arterial chemotherapy through the inferior or superior gluteal arteries. The distribution of infused drugs had been evaluated by RI-angiography through a thin arterial infusion catheter. This time we performed digital subtraction angiography (DSA) through an infusion catheter in order to know the precise distribution of infused materials in seven patients with locally advanced bladder cancer. Pharmaco-DSA with norepinephrine was also done in four patients. Satisfactory spatial and contrast resolution were gained in four patients and pharmaco-DSA showed better quality. In our experience DSA through intra-arterial infusion catheter was a useful procedure in the evaluation of distribution of infused drugs. (author)

  5. Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Kocasarac, Husniye Demirturk [Dept. of Comprehensive Dentistry, The University of Texas Health Science Center, San Antonio (United States); Celenk, Peruze [Dept. of Oral and Maxillofacial Radiology, Faculty of Dentistry, Ondokuz Mayis University, Samsun (Turkmenistan)

    2017-06-15

    Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (P<.05). DSR improved the accuracy of detection using panoramic images.

  6. Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

    Science.gov (United States)

    Celenk, Peruze

    2017-01-01

    Purpose Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Materials and Methods Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. Results The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. Conclusion The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (Ppanoramic images. PMID:28680846

  7. Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

    International Nuclear Information System (INIS)

    Kocasarac, Husniye Demirturk; Celenk, Peruze

    2017-01-01

    Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (P<.05). DSR improved the accuracy of detection using panoramic images

  8. Diagnosis of vertical root fractures in endodontically treated teeth utilising Digital Subtraction Radiography: A case series report.

    Science.gov (United States)

    Mikrogeorgis, Georgios; Eirinaki, Eleni; Kapralos, Vasileios; Koutroulis, Andreas; Lyroudia, Kleoniki; Pitas, Ioannis

    2017-12-11

    Vertical root fractures are commonly associated with root-filled teeth. Diagnosis is challenging because the clinical signs are not completely pathognomonic, and conventional periapical radiography is often unreliable. Digital subtraction radiography (DSR) is able to detect small radiographic changes between two successive radiographs by subtracting out consistent radiographic elements. Its use could possibly assist in the diagnostic procedure. Four cases are presented to demonstrate the potential use of DSR in the detection of vertical root fractures in endodontically treated teeth. After the digital subtractions had been carried out, a dark line in the body of the roots was distinguishable, raising the possibility of the presence of a vertical root fracture. The use of contrast enhancement and pseudocolouring techniques assisted with the diagnosis of vertical root fractures. DSR proved to be a useful diagnostic tool for the detection of vertical root fractures in these four clinical cases. © 2017 Australian Society of Endodontology Inc.

  9. Pilot study: digital subtraction radiography as a tool to assess alveolar bone changes in periodontitis patients under treatment with subantimicrobial doses of doxycycline

    NARCIS (Netherlands)

    Goren, A.D.; Dunn, S.M.; Wolff, M.; van der Stelt, P.F.; Colosi, D.C.; Golub, L.M.

    2008-01-01

    Background Subtle changes in marginal alveolar bone level can be demonstrated using digital subtraction of sequential radiographs. Objective We aimed to evaluate the practical application of geometrically corrected digital subtraction in a clinical study of alveolar bone response to a drug

  10. Evaluation of chronic periapical lesions by digital subtraction radiography by using Adobe Photoshop CS: a technical report.

    Science.gov (United States)

    Carvalho, Fabiola B; Gonçalves, Marcelo; Tanomaru-Filho, Mário

    2007-04-01

    The purpose of this study was to describe a new technique by using Adobe Photoshop CS (San Jose, CA) image-analysis software to evaluate the radiographic changes of chronic periapical lesions after root canal treatment by digital subtraction radiography. Thirteen upper anterior human teeth with pulp necrosis and radiographic image of chronic periapical lesion were endodontically treated and radiographed 0, 2, 4, and 6 months after root canal treatment by using a film holder. The radiographic films were automatically developed and digitized. The radiographic images taken 0, 2, 4, and 6 months after root canal therapy were submitted to digital subtraction in pairs (0 and 2 months, 2 and 4 months, and 4 and 6 months) choosing "image," "calculation," "subtract," and "new document" tools from Adobe Photoshop CS image-analysis software toolbar. The resulting images showed areas of periapical healing in all cases. According to this methodology, the healing or expansion of periapical lesions can be evaluated by means of digital subtraction radiography by using Adobe Photoshop CS software.

  11. A comparative study on the accuracy of digital subtraction radiography according to the acquisition methods of reconstructed images

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Young June; Jeon, In Seong; Heo, Min Suk; Park, Tae Won [College of Dentistry, Seoul National University, Seoul (Korea, Republic of); Lee, Sam Sun; Choi, Soon Chul [Department of Dentistry, Inje University Sanggyepaik Hospital, Seoul (Korea, Republic of); Kim, Jong Dae [Division of Information and Communication Engineering, Hallym University, Chuncheon (Korea, Republic of)

    2002-06-15

    To compare the accuracy of digital subtraction images acquired by two different methods different in positioning four reference points for geometrical standardization. A total of 36 digital radiographic images of 6 volunteers were taken at the areas of the incisor, premolar, and molar of both the maxilla and mandible using the Digora system. Each image was moved 4 mm vertically and horizontally. Four oral and maxillofacial radiologists performed digital subtraction radiography between the paired images before and after movement using Emago (Oral Diagnostic Systems, Amsterdam, The Netherlands) and Sunny (Biomedisys Co., Seoul, Korea). The standard deviation of the internal gray value in Region of Interest (ROI) was statistically analyzed between the two programs using the paired t-test. The standard deviation of pixel gray values from the digital subtraction images using the Sunny program were lower than that of the Emago program (p<0.05). All observers showed significant differences between each other when the Sunny program was used (p<0.05), but one observer showed a significantly higher score than other observers when they used Emago (p<0.05). The standard deviations of premolar area from both Sunny and Emago programs were significantly higher than those of anterior and molar regions (p<0.05). The subtracted images using the Sunny program were more accurate and sensitive than those taken using the Emago program.

  12. Digital subtraction radiography evaluation of the bone repair process of chronic apical periodontitis after root canal treatment.

    Science.gov (United States)

    Benfica e Silva, J; Leles, C R; Alencar, A H G; Nunes, C A B C M; Mendonça, E F

    2010-08-01

    To monitor radiographically the progress of bone repair within chronic periapical lesions after root canal treatment using digital subtraction radiography (DSR). Twelve patients with 17 single-rooted teeth with chronic apical periodontitis associated with an infected necrotic pulp were selected for root canal treatment. Periapical radiographs were taken before treatment (baseline) and immediately post-treatment, 45, 90, 135 and 180 days after treatment. The radiographic protocol included the use of individualized film holders with silicone bite blocks. The six radiographic images were digitized and submitted to digital subtraction using DSR software, resulting in five subtracted images (SI). Quantitative analysis of these SI was performed using Image Tool software to assess pixel value changes, considering a step-wedge as the gold standard and a cut-off value of 128 pixels. The aim was to identify any increase or decrease in mineral density in the region of the periapical lesion. A minor decrease in mineral density at the canal filling session and a significant progressive mineral gain in the following evaluations (P < 0.001) occurred. Pairwise comparison of pixel grey values revealed that only the 180-day follow-up differed significantly from the previous SI. Digital subtraction radiography is a useful method for evaluating the progress of bone repair after root canal treatment. Noticeable mineral gain was observed approximately 90 days after root canal filling and definite bone repair after 180 days.

  13. A digital subtraction radiography based tool for periodontal bone resorption analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schiabel, Homero; Rodrigues, Eveline B., E-mail: homero@sc.usp.br [University of Sao Paulo (EESC/USP), Sao Carlos, SP (Brazil). Dept. of Electrical Engineering; Rubira-Bullen, Izabel R.F. [University of Sao Paulo (USP), Bauru, SP (Brazil). Bauru Dentistry School

    2011-07-01

    The aim of this paper was to describe an aided diagnosis scheme for periodontal bone resorption so that the dentist can make an early diagnosis of the periodontal disease and establish the best treatment plan to increase the success of healing. Three ways of displaying the results are provided: qualitative, simple quantitative and colored-percentage quantitative views. A total of 72 pairs of in vitro radiographic images were used. The main procedure registers the images perspective projection aimed to align them in rotation and translation, and is followed by the application of a contrast correction technique. The results from the subtraction were evaluated firstly by the comparison between the actual and the digital sizes corresponding to the holes made by drills in phantoms. The mean error was 4.2%. The method was also applied to actual tooth radiographic images and could detect clearly the effect of treatment of periodontal diseases. It is dependent on the reproducibility of the process of radiographs acquisition and digitization, but the calculated mean error allows to conclude its better efficacy compared to usual procedures in this field. (author)

  14. A digital subtraction radiography based tool for periodontal bone resorption analysis

    International Nuclear Information System (INIS)

    Schiabel, Homero; Rodrigues, Eveline B.; Rubira-Bullen, Izabel R.F.

    2011-01-01

    The aim of this paper was to describe an aided diagnosis scheme for periodontal bone resorption so that the dentist can make an early diagnosis of the periodontal disease and establish the best treatment plan to increase the success of healing. Three ways of displaying the results are provided: qualitative, simple quantitative and colored-percentage quantitative views. A total of 72 pairs of in vitro radiographic images were used. The main procedure registers the images perspective projection aimed to align them in rotation and translation, and is followed by the application of a contrast correction technique. The results from the subtraction were evaluated firstly by the comparison between the actual and the digital sizes corresponding to the holes made by drills in phantoms. The mean error was 4.2%. The method was also applied to actual tooth radiographic images and could detect clearly the effect of treatment of periodontal diseases. It is dependent on the reproducibility of the process of radiographs acquisition and digitization, but the calculated mean error allows to conclude its better efficacy compared to usual procedures in this field. (author)

  15. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    International Nuclear Information System (INIS)

    Hanson, Eric H.; Roach, Cayce J.; Ringdahl, Erik N.; Wynn, Brad L.; DeChancie, Sean M.; Mann, Nathan D.; Diamond, Alan S.; Orrison, William W.

    2011-01-01

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  16. Computed tomography versus digital subtraction angiography for the diagnosis of obscure gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Wildgruber, Moritz; Wrede, Christian E.; Zorger, Niels; Müller-Wille, René; Hamer, Okka W.; Zeman, Florian; Stroszczynski, Christian; Heiss, Peter

    2017-01-01

    Purpose: The diagnostic yield of computed tomography angiography (CTA) compared to digital subtraction angiography (DSA) for major obscure gastrointestinal bleeding (OGIB) is not known. Aim of the study was to prospectively evaluate the diagnostic yield of CTA versus DSA for the diagnosis of major OGIB. Material and methods: The institutional review board approved the study and informed consent was obtained from each patient. Patients with major OGIB were prospectively enrolled to undergo both CTA and DSA. Two blinded radiologists each reviewed the CTA and DSA images retrospectively and independently. Contrast material extravasation into the gastrointestinal lumen was considered diagnostic for active bleeding. Primary end point of the study was the diagnostic yield, defined as the frequency a technique identified an active bleeding or a potential bleeding lesion. The diagnostic yield of CTA and DSA were compared by McNemar's test. Results: 24 consecutive patients (11 men; median age 64 years) were included. CTA and DSA identified an active bleeding or a potential bleeding lesion in 92% (22 of 24 patients; 95% CI 72%–99%) and 29% (7 of 24 patients; 95% CI 12%–49%) of patients, respectively (p < 0.001). CTA and DSA identified an active bleeding in 42% (10 of 24; 95% CI 22%–63%) and 21% (5 of 24; 95% CI 7%–42%) of patients, respectively (p = 0.06). Conclusion: Due to the lower invasiveness and higher diagnostic yield CTA should be favored over DSA for the diagnosis of major OGIB.

  17. Computed tomography versus digital subtraction angiography for the diagnosis of obscure gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Wildgruber, Moritz, E-mail: moritzwildgruber@ukmuenster.de [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Institut für klinische Radiologie, Universitätsklinikum Münster, D-48149 Münster (Germany); Wrede, Christian E. [Notfallzentrum, Helios Klinikum Berlin-Buch, D-13125 Berlin (Germany); Zorger, Niels [Institut für Radiologie, Neuroradiologie und Nuklearmedizin, Krankenhaus Barmherzige Brüder, D-93049 Regensburg (Germany); Müller-Wille, René; Hamer, Okka W. [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Zeman, Florian [Zentrum für Klinische Studien, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Stroszczynski, Christian; Heiss, Peter [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany)

    2017-03-15

    Purpose: The diagnostic yield of computed tomography angiography (CTA) compared to digital subtraction angiography (DSA) for major obscure gastrointestinal bleeding (OGIB) is not known. Aim of the study was to prospectively evaluate the diagnostic yield of CTA versus DSA for the diagnosis of major OGIB. Material and methods: The institutional review board approved the study and informed consent was obtained from each patient. Patients with major OGIB were prospectively enrolled to undergo both CTA and DSA. Two blinded radiologists each reviewed the CTA and DSA images retrospectively and independently. Contrast material extravasation into the gastrointestinal lumen was considered diagnostic for active bleeding. Primary end point of the study was the diagnostic yield, defined as the frequency a technique identified an active bleeding or a potential bleeding lesion. The diagnostic yield of CTA and DSA were compared by McNemar's test. Results: 24 consecutive patients (11 men; median age 64 years) were included. CTA and DSA identified an active bleeding or a potential bleeding lesion in 92% (22 of 24 patients; 95% CI 72%–99%) and 29% (7 of 24 patients; 95% CI 12%–49%) of patients, respectively (p < 0.001). CTA and DSA identified an active bleeding in 42% (10 of 24; 95% CI 22%–63%) and 21% (5 of 24; 95% CI 7%–42%) of patients, respectively (p = 0.06). Conclusion: Due to the lower invasiveness and higher diagnostic yield CTA should be favored over DSA for the diagnosis of major OGIB.

  18. Normal anatomy and variations in the confluence of sinuses using digital subtraction angiography.

    Science.gov (United States)

    Cheng, Yaqin; Li, William A; Fan, Xingjuan; Li, Xiaohua; Chen, Jian; Wu, Yan; Meng, Ran; Ji, Xunming

    2017-06-01

    The configuration of the confluence of sinuses differs not only between individuals, but also between the two brain hemispheres, making the anatomical classification of this region difficult. In this study, we evaluated the anatomy of the confluence of sinuses and ascertained the accuracy and usefulness of digital subtraction angiography (DSA) in the evaluation of cerebral veins. Bilateral carotid and vertebral artery angiographies were performed in 500 adult patients to evaluate the anatomy of the confluence of sinuses and contributory venous sinuses. We appraised the anatomy of the sinuses adjacent to the confluence, the lateralization of venous draining into the transverse sinuses (TSs), the communications between the TSs, and the presentation of the occipital sinus (OS). Based on the anatomical descriptions of Osborn's Brain (Diagnostic Cerebral Angiography, 2nd edition), we delineated 10 different configurations of the confluence of sinuses that showed connections among the superior sagittal sinus, the straight sinus, and the left and right TSs. Right side dominant transverse sinus accounted for 49% of the cases. Direct communication between the TSs accounted for 46.4% of the cases. Indirect communication accounted for 51.6% of the case, and absence of communication between the left and the right TS accounted for 2%. Lastly, the presence of OS was observed in 6% of the cases. DSA promises to be an effective technique for studying the anatomy and normal variations of the confluence of sinuses, providing useful information for the diagnosis of cerebral venous diseases, and ensuring safer surgical procedures.

  19. Analysis of the venous channel within the clivus using multidetector computed tomography digital subtraction venography.

    Science.gov (United States)

    Mizutani, Katsuhiro; Toda, Masahiro; Kurasawa, Jun; Akiyama, Takenori; Fujiwara, Hirokazu; Jinzaki, Masahiro; Yoshida, Kazunari

    2017-03-01

    Although neuroradiologists and skull base neurosurgeons are aware of the existence of veins within the clivus, such vessels have seldom been described in the literature. The aim of the present study is to elucidate the detailed venous structure of the clivus. Computed tomography digital subtraction venography (CT-DSV) images of 50 unruptured aneurysm cases were examined retrospectively. Eighteen emissary veins were identified in 14 (28.0%) cases. A half of the emissary veins connected the inferior petrosal sinus with the inferior petro-occipital vein (IPOV) in the middle clivus. The clival diploic vein (CDV) was identified in 14.0% of cases, 42.9% of which had the clivus of the presellar type. The CDV was connected to the posterior intercavernous sinus or the rostral end of the basilar plexus superiorly, and was connected to the IPOV, anterior condylar vein, marginal sinus, or the anterior condylar confluence. The CDV provides collateral channels between the cavernous sinus and the internal jugular vein and the inferior petrosal sinus and the IPOV. Understanding of the emissary veins in the clivus and the CDV is valuable for skull base surgery, especially for endonasal endoscopic skull base procedures.

  20. Remapping of digital subtraction angiography on a standard fluoroscopy system using 2D-3D registration

    Science.gov (United States)

    Alhrishy, Mazen G.; Varnavas, Andreas; Guyot, Alexis; Carrell, Tom; King, Andrew; Penney, Graeme

    2015-03-01

    Fluoroscopy-guided endovascular interventions are being performing for more and more complex cases with longer screening times. However, X-ray is much better at visualizing interventional devices and dense structures compared to vasculature. To visualise vasculature, angiography screening is essential but requires the use of iodinated contrast medium (ICM) which is nephrotoxic. Acute kidney injury is the main life-threatening complication of ICM. Digital subtraction angiography (DSA) is also often a major contributor to overall patient radiation dose (81% reported). Furthermore, a DSA image is only valid for the current interventional view and not the new view once the C-arm is moved. In this paper, we propose the use of 2D-3D image registration between intraoperative images and the preoperative CT volume to facilitate DSA remapping using a standard fluoroscopy system. This allows repeated ICM-free DSA and has the potential to enable a reduction in ICM usage and radiation dose. Experiments were carried out using 9 clinical datasets. In total, 41 DSA images were remapped. For each dataset, the maximum and averaged remapping accuracy error were calculated and presented. Numerical results showed an overall averaged error of 2.50 mm, with 7 patients scoring averaged errors < 3 mm and 2 patients < 6 mm.

  1. Comparative experimental study of dual energy subtraction and conventional digital radiography on chest

    International Nuclear Information System (INIS)

    Huang Rui; Feng Gansheng; Li Lin; Wei Qinghai

    2005-01-01

    Objective: To compare the efficiency of dual energy subtraction and conventional direct digital radiography in signal detecting ability. Methods: 200 plastic balls which were 4 mm in diameter were taken as signals and were placed on a 10 cm thick plastic board and the right upper thorax of a healthy volunteer. The signals were examined by DES and CDR separately and were estimated by 3 radiologists with 5-value-differentiation method. ROC curve analysis was made by ROC kit software. Results: when signals on plastic board were detected by CDR and DES, ROC curve analysis indicated that there was no significant difference (P=0.4851 > 0.05, two-tailed) between the area under the ROC curves of the two methods (Az=0.9931 for CDR and Az=0.9879 for DES). The difference was significant (P=0.0002 <0.01, two-tailed) between the area under the ROC curves of CDR and DES (Az=0.7276 for CDR and Az=0.8561 for DES), when the signals on the right upper thorax of a volunteer were detected by the two methods. Conclusion: DES surpasses CDR in detecting signals on thorax without superposition of ribs. There is good outlook in the application of DES in thorax examination. (authors)

  2. Patient radiation dose from computed tomography angiography and digital subtraction angiography of the brain

    Science.gov (United States)

    Netwong, Y.; Krisanachinda, A.

    2016-03-01

    The 64-row multidetector computed tomography angiography (64-MDCTA) provides vascular image quality of the brain similar to digital subtraction angiography (DSA), but the effective dose of CTA is lower than DSA studied in phantom. The purpose of this study is to evaluate the effective dose from 64-MDCTA and DSA. Effective dose (according to ICRP 103) from 64-MDCTA and DSA flat panel detector for cerebral vessels examination of the brain using standard protocols as recommended by the manufacturer was calculated for 30 cases of MDCTA (15 male and 15 female).The mean patient age was 49.5 (23-89) yrs. 30 cases of DSA (14 male and 16 female), the mean patient age was 46.8 (21-81) yrs. For CTA, the mean effective dose was 3.7 (2.82- 5.19) mSv. For DSA, the mean effective dose was 5.78 (3.3-10.06) mSv. The effective dose of CTA depends on the scanning protocol and scan length. Low tube current can reduce patient dose whereas the number of exposures and number of series in 3D rotational angiography (3D RA) resulted in increasing effective dose in DSA patients.

  3. Value of infusion-DSA (Digital Subtraction Angiography) in diagnosis of primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kwon, Jeong Mi; Kim, So Sun; Huh, Jin Do; Kim, Ho Joon; Chun, Byung Hee; Joh, Young Duk

    1991-01-01

    In order to evaluate diagnostic effectiveness of the infusion-study, the authors prospectively evaluated hepatic digital subtraction angiography of bolus and infusion studies in 71 patients with hepatocellular carcinoma. In contrast to Bolus-DSA, which involves a 2 second injection of 10cc of contrast medium, the Infusion-DSA uses a protracted (10sec) injection, a lower injection rate, and larger total dose of contrast medium (20cc). The information yield of arterial and capillary phases of Infusion-DSA was compared with that of Bolus-DSA and graded as 'improved(+)', 'equivalent( ± )', or 'poor(-)'. Also, the contribution of Infusion-DSA to the diagnosis was classified into one of five in a graded system. In 29 hepatocellular patients, the Infusion-DSA was helpful in detecting daughter nodules, fibrous capsule and arteriovenous shunt. Infusion-DSA is a useful complementary technique in the diagnosis of hepatocellular carcinoma and was also helpful in determining the selection of the therapeutic modality of hepatocellular carcinoma

  4. A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT

    Directory of Open Access Journals (Sweden)

    Cristian T. Badea

    2013-01-01

    Full Text Available CT and digital subtraction angiography (DSA are ubiquitous in the clinic. Their preclinical equivalents are valuable imaging methods for studying disease models and treatment. We have developed a dual source/detector X-ray imaging system that we have used for both micro-CT and DSA studies in rodents. The control of such a complex imaging system requires substantial software development for which we use the graphical language LabVIEW (National Instruments, Austin, TX, USA. This paper focuses on a LabVIEW platform that we have developed to enable anatomical and functional imaging with micro-CT and DSA. Our LabVIEW applications integrate and control all the elements of our system including a dual source/detector X-ray system, a mechanical ventilator, a physiological monitor, and a power microinjector for the vascular delivery of X-ray contrast agents. Various applications allow cardiac- and respiratory-gated acquisitions for both DSA and micro-CT studies. Our results illustrate the application of DSA for cardiopulmonary studies and vascular imaging of the liver and coronary arteries. We also show how DSA can be used for functional imaging of the kidney. Finally, the power of 4D micro-CT imaging using both prospective and retrospective gating is shown for cardiac imaging.

  5. Magnetization spoiling in radial FLASH contrast-enhanced MR digital subtraction angiography.

    Science.gov (United States)

    Vakil, Parmede; Ansari, Sameer A; Hurley, Michael C; Bhat, Himanshu; Batjer, H Hunt; Bendok, Bernard R; Eddleman, Christopher S; Carroll, Timothy J

    2012-07-01

    To increase the in-plane spatial resolution and image update rates of 2D magnetic resonance (MR) digital subtraction angiography (DSA) pulse sequences to 0.57 × 0.57 mm and 6 frames/sec, respectively, for intracranial vascular disease applications by developing a radial FLASH protocol and to characterize a new artifact, not previously described in the literature, which arises in the presence of such pulse sequences. The pulse sequence was optimized and artifacts were characterized using simulation and phantom studies. With Institutional Review Board (IRB) approval, the pulse sequence was used to acquire time-resolved images from healthy human volunteers and patients with x-ray DSA-confirmed intracranial vascular disease. Artifacts were shown to derive from inhomogeneous spoiling due to the nature of radial waveforms. Gradient spoiling strategies were proposed to eliminate the observed artifact by balancing gradient moments across TR intervals. The resulting radial 2D MR DSA sequence (2.6 sec temporal footprint, 6 frames/sec with sliding window factor 16, 0.57 × 0.57 mm in-plane) demonstrated small vessel detail and corroborated x-ray DSA findings in intracranial vascular imaging studies. Appropriate gradient spoiling in radial 2D MR DSA pulse sequences improves intracranial vascular depiction by eliminating circular banding artifacts. The proposed pulse sequence may provide a useful addition to clinically applied 2D MR DSA scans. Copyright © 2012 Wiley Periodicals, Inc.

  6. Predictive value of digital subtraction angiography in patients with tuberculous meningitis

    International Nuclear Information System (INIS)

    Rojas-Echeverri, L.A.; Soto-Hernandez, J.L.; Garza, S.; Martinez-Zubieta, R.; Miranda, L.I.; Garcia-Ramos, G.; Zenteno, M.

    1996-01-01

    Digital subtraction angiography (DSA) was performed in 24 adults with tuberculous meningitis (TBM) and results were correlated with 24 admission and 16 follow-up CT examinations. 19 MRI studies and clinical outcome at a mean follow-up of 44 weeks. DSA was abnormal in 11 patients. Abnormal DSA was associated with advenced clinical stages of the Medical Research Council classification, admission CT with hydrocephalus or gyral cortical enhancement. MRI disclosed brain infarcts not seen on initial CT in 8 cases. Of seven patients who died, 4 had abnormal and 3 normal DSA. Among patients who survived, those with normal DSA had a better functional outcome by Karnofsky scores. During follow-up infarcts were evident in 16 patients. Abnormal DSA in relation to brain infarcts had a sensitivity of 0.56, specificity 0.75, positive predictive value 0.82 and negative predictive value 0.46. A single arteriogram does not predict the outcome in patients with TBM and its value is limited in the assessment of vascular complications of TBM. Angiography in TBM is justified only in specific clinical trials to assess new therapeutic modalities against infarcts. (orig.)

  7. A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT.

    Science.gov (United States)

    Badea, Cristian T; Hedlund, Laurence W; Johnson, G Allan

    2013-01-01

    CT and digital subtraction angiography (DSA) are ubiquitous in the clinic. Their preclinical equivalents are valuable imaging methods for studying disease models and treatment. We have developed a dual source/detector X-ray imaging system that we have used for both micro-CT and DSA studies in rodents. The control of such a complex imaging system requires substantial software development for which we use the graphical language LabVIEW (National Instruments, Austin, TX, USA). This paper focuses on a LabVIEW platform that we have developed to enable anatomical and functional imaging with micro-CT and DSA. Our LabVIEW applications integrate and control all the elements of our system including a dual source/detector X-ray system, a mechanical ventilator, a physiological monitor, and a power microinjector for the vascular delivery of X-ray contrast agents. Various applications allow cardiac- and respiratory-gated acquisitions for both DSA and micro-CT studies. Our results illustrate the application of DSA for cardiopulmonary studies and vascular imaging of the liver and coronary arteries. We also show how DSA can be used for functional imaging of the kidney. Finally, the power of 4D micro-CT imaging using both prospective and retrospective gating is shown for cardiac imaging.

  8. DIAGNOSTIC ACCURACY OF MAGNETIC RESONANCE ANGIOGRAPHY FOR UNRUPTURED CEREBRAL ANEURYSMS IN CORRELATION WITH DIGITAL SUBTRACTION ANGIOGRAPHY

    Directory of Open Access Journals (Sweden)

    Aleksandra Aracki-Trenkić

    2015-09-01

    Full Text Available Intracranial aneurysm is a focal, abnormal dilation of an artery of the brain. Magnetic resonance angiography (MRA is a non-invasive technique for vascular imaging and is thus widely used for screening for intracranial vascular lesions. The aim of the study was to show the diagnostic accuracy of 3D Time-of-Flight (3D TOF MRA in the detection of unruptured cerebral aneurysms with the use of digital subtraction angiography (DSA as the gold standard. A total of 2.612 consecutive patients underwent 3DTOF MRA. It showed unruptured aneurysms in 94 (3.6% patients. They included 68 women and 26 men ranging in age from 29 to 76 years (mean, 52.5 years. Twenty-six of them, 20 women and 6 men, underwent DSA. The Mann-Whitney U test was used for the correlation of size. Fisher’s test was used for the correlation of location. The statistical level of significance was set at p0.05 of aneurysms between TOF MRA and DSA. MRA is an accurate and non-invasive method for diagnosis of unruptured intracranial aneurysms. The results of study show the compatibility of MRA findings, the location and the size of an aneurysm in comparison with the “gold standard” – cerebral DSA.

  9. Clinical application of cerebral circulation time measured by intra-arterial digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Yoshikazu; Shima, Takeshi; Nishida, Masahiro; Yamane, Kanji; Okita, Shinji; Yoshida, Akira; Naoe, Yasutaka; Shiga, Naoko (Chugoku Rosai Hospital, Hiroshima (Japan))

    1994-08-01

    Digital subtraction angiography (DSA) made it possible not only to visualize the intracranial fine vasculature but also measure the density of contrast medium at the arbitrary region of interest (ROI). In this study we applied this intra-arterial DSA (IA-DSA) to measure cerebral circulation time by obtaining time-density curve at the two ROI's at the C3-C4 portion and the Rolandic vein. Circulation time was defined by the time difference between the peak optical density time at the two sites. The control value of circulation time was 3.4 sec on the average, which correlated with the age of cases. In patients with occlusive cerebrovascular diseases such as carotid arterial occlusion or with mass lesions such as hematoma and brain tumor, circulation time was significantly delayed. On the contrary, circulation time in arteriovenous malformation was demonstrated to be very short. Additionally circulation time was investigated in subarachnoid hemorrhage due to ruptured aneurysm. Circulation time in patients with none, slight to moderate and severe vasospasm following subarachnoid hemorrhage were 3.6, 4.3 and 6.8 sec on the average, respectively. And ten patients presenting with low densitity area on CT scans showed significantly long circulation time, 7.0 sec on the average. From these studies cerebral circulation time by IA-DSA would be one of the useful methods to clarify cerebral hemodynamics. (author).

  10. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, Eric H. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); Amigenics, Inc, Las Vegas, NV (United States); Roach, Cayce J. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); University of Nevada Las Vegas, School of Life Sciences, Las Vegas, NV (United States); Ringdahl, Erik N. [University of Nevada Las Vegas, Department of Psychology, Las Vegas, NV (United States); Wynn, Brad L. [Family Medicine Spokane, Spokane, WA (United States); DeChancie, Sean M.; Mann, Nathan D. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); Diamond, Alan S. [CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); Orrison, William W. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); University of Nevada School of Medicine, Department of Medical Education, Reno, NV (United States)

    2011-05-15

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  11. Comparison of 3D magnetic resonance imaging and digital subtraction angiography for intracranial artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji Eun; Jung, Seung Chai; Kim, Ho Sung; Choi, Choong-Gon; Kim, Sang Joon; Lee, Deok Hee [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Lee, Sang Hun; Kwon, Sun U.; Kang, Dong-Wha; Kim, Jong S. [University of Ulsan College of Medicine, Department of Neurology, Ulsan (Korea, Republic of); Jeon, Ji Young [Gachon University, Department of Radiology, Gil Medical Center, Incheon (Korea, Republic of); Lee, Ji Ye [Soonchunhyang University Bucheon Hospital, Department of Radiology, Bucheon (Korea, Republic of); Kim, Seon-Ok [University of Ulsan College of Medicine, Department of Clinical Epidemiology and Biostatistics, Asan Medical Center, Seoul (Korea, Republic of)

    2017-11-15

    To compare three-dimensional high-resolution magnetic resonance imaging (3D HR-MRI) and digital subtraction angiography (DSA) for diagnosing and evaluating stenosis in the entire circle of Willis. The study included 516 intracranial arteries from 43 patients with intracranial artery stenosis (ICAS) who underwent both 3D HR-MRI and DSA within 1 month. Two readers independently diagnosed atherosclerosis, dissection, moyamoya disease and vasculitis, rated their diagnostic confidence for each vessel and measured the luminal diameters. Reference standard was made from clinico-radiologic diagnosis. Diagnostic accuracy, diagnostic confidence, the degree of stenosis and luminal diameter were assessed and compared between both modalities. For atherosclerosis, 3D HR-MRI showed better diagnostic accuracy (P =.03-.003), sensitivity (P =.006-.01) and positive predictive value (P ≤.001-.006) compared to DSA. Overall, the readers were more confident of their diagnosis of ICAS when using 3D HR-MRI (reader 1, P ≤.001-.007; reader 2, P ≤.001-.015). 3D HR-MRI showed similar degree of stenosis (P >.05) and higher luminal diameter (P <.05) compared to DSA. 3D HR-MRI might be useful to evaluate atherosclerosis, with better diagnostic confidence and comparable stenosis measurement compared to DSA in the entire circle of Willis. (orig.)

  12. In vivo optical imaging of amblyopia: Digital subtraction autofluorescence and split-spectrum amplitude-decorrelation angiography.

    Science.gov (United States)

    Guo, Lei; Tao, Jun; Xia, Fan; Yang, Zhi; Ma, Xiaoli; Hua, Rui

    2016-09-01

    Amblyopia is a visual impairment that is attributed to either abnormal binocular interactions or visual deprivation. The retina and choroids have been shown to be involved in the development of amblyopia. The purpose of this study was to investigate the retinal and choroidal microstructural abnormalities of amblyopia using digital subtraction autofluorescence and split-spectrum amplitude-decorrelation angiography (SSADA) approaches. This prospective study included 44 eyes of 22 patients with unilateral amblyopia. All patients who received indirect ophthalmoscopy, combined depth imaging spectral domain optical coherence tomography (OCT), SSADA-OCT, and macular blue light (BL-) and near-infrared (NIR-) autofluorescences underwent pupil dilation. The subfoveal choroidal thickness (SFCT) was measured. BL- and NIR-autofluorescences were determined for all patients and used to generate subtraction images with ImageJ software. The superficial, deep layers of the retina, and inner choroid layer were required for SSADA-OCT. For the normal eyes, a regularly increasing signal was observed in the central macula based on the subtraction images. In contrast, a decreased signal for the central patch or a reduced peak was detected in 16 of 22 amblyopic eyes (72.7%). The mean SFCT of the amblyopic eyes was greater than that of the fellow normal eyes (399.25 ± 4.944 µm vs. 280.58 ± 6.491 µm, respectively, P amblyopia using SSADA-OCT and digital subtraction images of autofluorescence. The mechanistic relationship of a thicker choroid and choroidal capillary atrophy with amblyopia remains to be described. The digital subtraction image confirmed the changes in the microstructure of the amblyopic retina as a supplementary approach to detect the progression of amblyopia. Lasers Surg. Med. 48:660-667, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  13. Regional myocardial coronary blood flow reserve in hypertrophic cardiomyopathy assessed by digital subtraction coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Terashima, Satoshi; Nakamura, Takashi; Furukawa, Keizo (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1992-01-01

    Using digital subtraction coronary angiography (DSA), we evaluated the regional myocardial coronary blood flow reserve (rMFR) in 18 patients with hypertrophic cardiomyopathy (HCM). There were 13 patients with asymmetrical septal hypertrophy (ASH), and 5 with asymmetrical apical hypertrophy (AAH). Eight subjects without apparent cardiac abnormality served as controls. Relations between the rMFR and regional wall thickness, as determined by echocardiography, were also investigated. Peak contrast density (Cm) and time to Cm (Tm) were measured from digital angiograms at the middle and distal ventricular septum (VS) and at the apical and left ventricular posterior wall (PW). The rMFR of each region of interest was expressed as the ratio of Cm/Tm at the baseline and at peak hyperemic response induced by intracoronary administration of papaverine. The rMFR was significantly lower at the VS and apex in HCM than in controls: middle VS, 1.9[+-]0.5 vs 3.9[+-]0.5, p<0.001; distal VS, 2.0[+-]0.5 vs 4.4[+-]0.9, p<0.001; and the apex, 2.0[+-]0.7 vs 4.5[+-]1.6, p<0.01. However, it did not differ at the PW; 2.6[+-]0.9 vs 3.0[+-]0.9 between the 3 groups. The middle VS and apex, where the wall was the thickest, had the lowest rMFR in ASH and AAH. Furthermore, at the VS and apex, a curvilinear relationship was observed between the rMFR and wall thickness (rMFR=-0.88 ln WT+2.39, r=-0.57, p<0.001). These results indicated that disproportionate hypertrophy contributes to impairment of the rMFR, and that the decreased rMFR may be one of the significant causes of reversible myocardial ischemia in patients with HCM. (author).

  14. The comparative study on diagnostic validity of cerebral aneurysm by computed tomography angiography versus digital subtraction angiography after subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Masih Saboori

    2011-01-01

    Full Text Available Background: In order to declare the preoperative diagnostic value of brain aneurysms, two radiological modalities, computed tomographic angiography and digital subtraction angiography were compared. Methods: In this descriptive analytic study, diagnostic value of computed tomographic angiography (CTA was com-pared with digital subtraction angiography (DSA. Sensitivity, specificity, positive and negative predictive values were calculated and compared between the two modalities. All data were analyzed with SPSS software, version 16. Results: Mean age of patients was 49.5 ± 9.13 years. 57.9 % of subjects were female. CTA showed 89% sensitivity and 100% specificity whereas DSA demonstrated 74% sensitivity and 100% specificity. Positive predictive value of both methods was 100%, but negative predictive value of CTA and DSA was 85% and 69%, respectively. Conclusions: Based on our data, CTA is a valuable diagnostic modality for detection of brain aneurysm and su-barachnoid hemorrhage.

  15. Comparative study of conducting iliac angioplasties with digital subtraction and conventional angiography. Incidence on true (consumable) costs

    International Nuclear Information System (INIS)

    Brenot, P.; Raynaud, A.; Pernes, J.M.; Parola, J.L.; Gaux, J.C.

    1986-01-01

    Differences in time and cost were evaluated between the performance of iliac angioplasty with conventional (AC) and digital subtraction (AN) angiography, after a total of 27 angioplasties (13 with AC and 14 with AN). Excluding amortization of material and personnel costs, findings confirmed a certain number of advantages for AN: gain in time of about 34%, decrease of about 14% in charges, and notably of 83% in expenditure on films and 50% on contrast media [fr

  16. Multi-section CT angiography compared with digital subtraction angiography in diagnosing major arterial hemorrhage in inflammatory pancreatic disease

    International Nuclear Information System (INIS)

    Hyare, Harpreet; Desigan, Sharmini; Nicholl, Helen; Guiney, Michael J.; Brookes, Jocelyn A.; Lees, William R.

    2006-01-01

    Purpose: Major arterial hemorrhage is an uncommon but serious complication of pancreatitis with high morbidity and mortality. Digital subtraction angiography (DSA) has long been the gold standard for the detection of a visceral artery pseudoaneurysm or for the site of active bleeding in patients with pancreatitis. Multi-section CT angiography is a minimally invasive technique which can provide high-resolution and high-contrast images of the arterial lumen and wall, with a much lower risk of complication and morbidity compared to DSA. The aim of this study was to determine the accuracy of multi-section CT angiography for the diagnosis of arterial complications of inflammatory pancreatitic disease. Materials and methods: A retrospective analysis of all patients undergoing visceral angiography for major bleeding as a complication of pancreatitis between 1998 and 2004 was performed. Twenty-nine studies in 25 patients (20 males, 5 females) with a mean age of 50.9 years (range 11-67 years) were identified where multi-section CT angiography was performed in the 24 h preceding the digital subtraction angiogram. Results: Digital subtraction angiography detected a pseudoaneurysm or contrast extravasation in 19 studies and no bleeding was demonstrated in 9 studies. CT angiography correctly identified the site and type of bleeding in 18 of the 19 positive studies. CT angiography detected extravasation of contrast in one study that was not demonstrated on digital subtraction angiography. The sensitivity and specificity for multi-section CT angiography for the detection of major arterial bleeding on a background of pancreatitis were 0.947 and 0.900, respectively. Conclusion: Multi-section CT angiography is a sensitive and accurate technique for the detection of major arterial hemorrhage in inflammatory pancreatic disease and should be considered as the first investigation in the management of these patients

  17. Classification-based summation of cerebral digital subtraction angiography series for image post-processing algorithms.

    Science.gov (United States)

    Schuldhaus, D; Spiegel, M; Redel, T; Polyanskaya, M; Struffert, T; Hornegger, J; Doerfler, A

    2011-03-21

    X-ray-based 2D digital subtraction angiography (DSA) plays a major role in the diagnosis, treatment planning and assessment of cerebrovascular disease, i.e. aneurysms, arteriovenous malformations and intracranial stenosis. DSA information is increasingly used for secondary image post-processing such as vessel segmentation, registration and comparison to hemodynamic calculation using computational fluid dynamics. Depending on the amount of injected contrast agent and the duration of injection, these DSA series may not exhibit one single DSA image showing the entire vessel tree. The interesting information for these algorithms, however, is usually depicted within a few images. If these images would be combined into one image the complexity of segmentation or registration methods using DSA series would drastically decrease. In this paper, we propose a novel method automatically splitting a DSA series into three parts, i.e. mask, arterial and parenchymal phase, to provide one final image showing all important vessels with less noise and moving artifacts. This final image covers all arterial phase images, either by image summation or by taking the minimum intensities. The phase classification is done by a two-step approach. The mask/arterial phase border is determined by a Perceptron-based method trained from a set of DSA series. The arterial/parenchymal phase border is specified by a threshold-based method. The evaluation of the proposed method is two-sided: (1) comparison between automatic and medical expert-based phase selection and (2) the quality of the final image is measured by gradient magnitudes inside the vessels and signal-to-noise (SNR) outside. Experimental results show a match between expert and automatic phase separation of 93%/50% and an average SNR increase of up to 182% compared to summing up the entire series.

  18. Comparison of CT angiography and digital subtraction angiography in the evaluation of intracranial aneurysmal neck

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Baik, Seung Kug; Shin, Mi Jeong; Choi, Han Yong

    2001-01-01

    To compare the usefulness of three-dimensional multislice CT angiography(CTA) and digital subtraction angiography (DSA) in the evaluation of intracranial aneurysmal neck. Nineteen patients with intracranial aneurysm (23 cases) underwent DSA and subsequent CTA. Using a multislice CT scanner and the SSD(shaded surface display) technique, clipping, cutting and the MPR technique, three-dimensional images were obtained. These were (a) external, (b) internal, from the direction of the parent artery, (c) internal, from the direction of the aneurysmal dome, and (d) an aneurysmal cutting image. The CTA findings were retrospectively compared with the DSA images. Twenty aneurysms were small and three were large. In eleven cases aneurysm neck was small, in nine it was wide, and in three it was relatively wide. For aneurysmal neck evaluation, CTA was superior to DSA in six of nine wide-neck aneurysms and all three large-sized wide-neck aneurysms. In small neck aneurysms 8 of 11 cases and in relatively wide neck all 3 cases showed similarly good images by both modalities. Of the 23 cases demonstrated by four different images, 14 cases showed the best image in internal image from parent artery direction and 6 cases showed similarly good image in both aneurysmal cutting image and internal image from parent artery direction. In the evaluation of wide neck aneurysms, 7 of 9 cases showed the best image at internal image from parent artery direction, compared with other three different images. In two cases of aneurysms, calcification was visible in the aneurysmal wall, so it was difficult to evaluate the aneurysmal neck. CTA was superior to DSA in the evaluating the intracranial aneurysmal neck. CTA maybe an additional available modality to evaluate the aneurysmal neck which is difficult to detect by the DSA. And the information of intracranial aneurysmal neck through CTA will be of value in surgical and endovascular treatment

  19. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    International Nuclear Information System (INIS)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan

    2009-01-01

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 μm 2 ). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0±5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO DSA =CO Fick . Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  20. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan [Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States)

    2009-11-15

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 {mu}m{sup 2}). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0{+-}5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO{sub DSA}=CO{sub Fick}. Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  1. Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: comparison with digital subtraction angiography.

    Science.gov (United States)

    Pozzi-Mucelli, Fabio; Bruni, Stefano; Doddi, Marco; Calgaro, Antonio; Braini, Massimiliano; Cova, Maria

    2007-10-01

    To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect.

  2. Comparisons of images simultaneously documented by digital subtraction coronary arteriography and cine coronary arteriography

    International Nuclear Information System (INIS)

    Kimura, Koji; Takamiya, Makoto; Yamamoto, Kazuo; Ohta, Mitsushige; Naito, Hiroaki

    1988-01-01

    Using an angiography apparatus capable of simultaneously processing digital subtraction angiograms and cine angiograms, the diagnostic capabilities of both methods for the coronary arteries (DSCAG and Cine-CAG) were compared. Twenty stenotic lesions of the coronary arteries of 11 patients were evaluated using both modalities. The severity of stenosis using DSCAG with a 512x512x8 bit matrix was semiautomatically measured on the cathode ray tube (CRT) based on enlarged images on the screen of a Vanguard cine projector which were of the same size as those of or 10 times larger than images of Cine-CAG. The negative and positive hard copies of DSCAG images were also compared with those of Cine-CAG. The correlation coefficients of the severity of stenosis by DSCAG and Cine-CAG were as follows: (1) the same size DSCAG images on CRT to Cine-CAG, 0.95, (2) 10 times enlarged DSCAG images on CRT to Cine-CAG, 0.96, and (3) the same size DSCAG images on negative and positive hard copies to Cine-CAG, 0.97. The semiautomatically measured values of 10 times enlarged DSCAG images on CRT and the manually measured values of the same size negative and positive DSCAG images in hard copy closely correlated with the values measured using Cine-CAG. When the liver was superimposed in the long-axis projection, the diagnostic capabilities of DSCAG and Cine-CAG were compared. The materials included 10 left coronary arteriograms and 11 right coronary arteriograms. Diagnostically, DSCAG was more useful than Cine-CAG in the long-axis projection. (author)

  3. Classification-based summation of cerebral digital subtraction angiography series for image post-processing algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Schuldhaus, D; Spiegel, M; Polyanskaya, M; Hornegger, J [Pattern Recognition Lab, University Erlangen-Nuremberg (Germany); Redel, T [Siemens AG Healthcare Sector, Forchheim (Germany); Struffert, T; Doerfler, A, E-mail: martin.spiegel@informatik.uni-erlangen.de [Department of Neuroradiology, University Erlangen-Nuremberg (Germany)

    2011-03-21

    X-ray-based 2D digital subtraction angiography (DSA) plays a major role in the diagnosis, treatment planning and assessment of cerebrovascular disease, i.e. aneurysms, arteriovenous malformations and intracranial stenosis. DSA information is increasingly used for secondary image post-processing such as vessel segmentation, registration and comparison to hemodynamic calculation using computational fluid dynamics. Depending on the amount of injected contrast agent and the duration of injection, these DSA series may not exhibit one single DSA image showing the entire vessel tree. The interesting information for these algorithms, however, is usually depicted within a few images. If these images would be combined into one image the complexity of segmentation or registration methods using DSA series would drastically decrease. In this paper, we propose a novel method automatically splitting a DSA series into three parts, i.e. mask, arterial and parenchymal phase, to provide one final image showing all important vessels with less noise and moving artifacts. This final image covers all arterial phase images, either by image summation or by taking the minimum intensities. The phase classification is done by a two-step approach. The mask/arterial phase border is determined by a Perceptron-based method trained from a set of DSA series. The arterial/parenchymal phase border is specified by a threshold-based method. The evaluation of the proposed method is two-sided: (1) comparison between automatic and medical expert-based phase selection and (2) the quality of the final image is measured by gradient magnitudes inside the vessels and signal-to-noise (SNR) outside. Experimental results show a match between expert and automatic phase separation of 93%/50% and an average SNR increase of up to 182% compared to summing up the entire series.

  4. A 2D driven 3D vessel segmentation algorithm for 3D digital subtraction angiography data

    Energy Technology Data Exchange (ETDEWEB)

    Spiegel, M; Hornegger, J [Pattern Recognition Lab, University Erlangen-Nuremberg, Erlangen (Germany); Redel, T [Siemens AG Healthcare Sector, Forchheim (Germany); Struffert, T; Doerfler, A, E-mail: martin.spiegel@informatik.uni-erlangen.de [Department of Neuroradiology, University Erlangen-Nuremberg, Erlangen (Germany)

    2011-10-07

    Cerebrovascular disease is among the leading causes of death in western industrial nations. 3D rotational angiography delivers indispensable information on vessel morphology and pathology. Physicians make use of this to analyze vessel geometry in detail, i.e. vessel diameters, location and size of aneurysms, to come up with a clinical decision. 3D segmentation is a crucial step in this pipeline. Although a lot of different methods are available nowadays, all of them lack a method to validate the results for the individual patient. Therefore, we propose a novel 2D digital subtraction angiography (DSA)-driven 3D vessel segmentation and validation framework. 2D DSA projections are clinically considered as gold standard when it comes to measurements of vessel diameter or the neck size of aneurysms. An ellipsoid vessel model is applied to deliver the initial 3D segmentation. To assess the accuracy of the 3D vessel segmentation, its forward projections are iteratively overlaid with the corresponding 2D DSA projections. Local vessel discrepancies are modeled by a global 2D/3D optimization function to adjust the 3D vessel segmentation toward the 2D vessel contours. Our framework has been evaluated on phantom data as well as on ten patient datasets. Three 2D DSA projections from varying viewing angles have been used for each dataset. The novel 2D driven 3D vessel segmentation approach shows superior results against state-of-the-art segmentations like region growing, i.e. an improvement of 7.2% points in precision and 5.8% points for the Dice coefficient. This method opens up future clinical applications requiring the greatest vessel accuracy, e.g. computational fluid dynamic modeling.

  5. Parametric color coding of digital subtraction angiography in the evaluation of carotid cavernous fistulas.

    Science.gov (United States)

    Gölitz, P; Struffert, T; Lücking, H; Rösch, J; Knossalla, F; Ganslandt, O; Deuerling-Zheng, Y; Doerfler, A

    2013-06-01

    Angiographic assessment of carotid cavernous fistulas (CCFs) can be complex. Our purpose was to examine whether the use of parametric color coding in the postprocessing of DSA series is advantageous in the evaluation of CCFs. We enrolled 16 patients with angiographically proven CCFs. Endovascular treatment was performed in 14 cases. For postprocessing of digital subtraction angiography (DSA) series, a newly implemented algorithm of parametric color coding was used, turning sequential images of two-dimensional (2D)-DSA series into a single color-coded image. Angiographic data of initial, interventional, and postinterventional 2D-DSA series were compared with color-coded images. Whether parametric color coding could facilitate evaluation of fistula architecture and provide a more precise estimation of fistula venous drainage patterns as well as whether flow analysis could reveal objective changes during and after treatment were investigated. In 56 % of the cases, parametric color coding was observed to facilitate visualization of fistula angioarchitecture. Estimation of fistula drainage flow patterns was considered to be improved in 31 % of the cases. For assessment of hemodynamic changes during and after treatment, parametric color coding was assumed to be helpful in 21 % of the cases, especially because revealing flow changes that were not visible on 2D-DSA series were now visible. Parametric color coding is a fast application tool that might provide additional support in the angiographic evaluation of CCFs. Visualization of complex fistula architecture could be facilitated, and flow analysis might improve assessment of venous drainage patterns, thereby increasing overall diagnostic confidence. During and after treatment, hemodynamic changes that were not visible on 2D-DSA series could now be depicted.

  6. A 2D driven 3D vessel segmentation algorithm for 3D digital subtraction angiography data

    International Nuclear Information System (INIS)

    Spiegel, M; Hornegger, J; Redel, T; Struffert, T; Doerfler, A

    2011-01-01

    Cerebrovascular disease is among the leading causes of death in western industrial nations. 3D rotational angiography delivers indispensable information on vessel morphology and pathology. Physicians make use of this to analyze vessel geometry in detail, i.e. vessel diameters, location and size of aneurysms, to come up with a clinical decision. 3D segmentation is a crucial step in this pipeline. Although a lot of different methods are available nowadays, all of them lack a method to validate the results for the individual patient. Therefore, we propose a novel 2D digital subtraction angiography (DSA)-driven 3D vessel segmentation and validation framework. 2D DSA projections are clinically considered as gold standard when it comes to measurements of vessel diameter or the neck size of aneurysms. An ellipsoid vessel model is applied to deliver the initial 3D segmentation. To assess the accuracy of the 3D vessel segmentation, its forward projections are iteratively overlaid with the corresponding 2D DSA projections. Local vessel discrepancies are modeled by a global 2D/3D optimization function to adjust the 3D vessel segmentation toward the 2D vessel contours. Our framework has been evaluated on phantom data as well as on ten patient datasets. Three 2D DSA projections from varying viewing angles have been used for each dataset. The novel 2D driven 3D vessel segmentation approach shows superior results against state-of-the-art segmentations like region growing, i.e. an improvement of 7.2% points in precision and 5.8% points for the Dice coefficient. This method opens up future clinical applications requiring the greatest vessel accuracy, e.g. computational fluid dynamic modeling.

  7. Decreasing radiation doses in digital subtraction angiographies consecutively performed by trainees

    International Nuclear Information System (INIS)

    Xu, G.; Zhao, W.; Zheng, L.; Fan, X.; Yin, Q.; Liu, X.

    2012-01-01

    Digital subtraction angiography (DSA) performed by trainees may be related to increased radiation exposure. This study was aimed to investigate and quantify this learning effect, with fluoroscopy time and dose-area product (DAP) as parameters. We collected procedure data of the first to the fortieth cerebral DSA consecutively performed by 13 trainees in a training centre. DAP, procedure time, fluoroscopy time, number of cine-frames of the first 20 DSA procedures performed by these trainees were compared with that of the second 20 procedures. There was no significant difference concerning the procedure time between the first and the second 20 procedures (56.3 ±29.5 vs 51.5±20.2 min, p = 0.113). Numbers of cine-frames were very similar between the first and the second 20 procedures (750.7 ±290.3 vs 744.5 ±188.7, p = 0.830). Fluoroscopy time of the first 20 procedures was significantly longer than that of the second 20 procedures (17.8 ±15.4 vs 12.6 ±9.0, p = 0.001). DAP of the first 20 procedures was significantly higher than that of the second 20 procedures (6.4 ±4.9 vs 3.8 ±1.8, p < 0.001). DAP was correlated significantly with the performer's experience (R = -0.288, p < 0.001). There exists a learning effect of radiation exposure during cerebral DSA procedures performed by trainees. The learning effect is significant during the first 20 procedures, and becomes insignificant after 20 procedures. Insufficient catheter skills in novice trainees may be one reason for this effect. (authors)

  8. Temporal Subtraction of Digital Breast Tomosynthesis Images for Improved Mass Detection

    National Research Council Canada - National Science Library

    Li, Christina M

    2007-01-01

    .... The purpose of this project is to determine the feasibility of using temporal subtraction on DBT phantom images to allow for easier and earlier detection of breast cancer than with either technique alone...

  9. Comparison of conventional panoramic radiography and panoramic digital subtraction radiography in detection of simulated lesions of mandibular condyle

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2008-12-01

    Full Text Available "n  "nBackground and Aim: Digital subtraction Radiography (DSR is a method of accurate assessing condylar head changes. several studies have been carried out in applying DSR in dentistry, however there is a few number of studies in efficacy of DSR method in assesment of condylar head changes, The aim of this study was to compare panoramic radiography and DSR detecting simulated lesions of the mandibular condyl. "nMaterials and Methods: this was a process reaserch study, in which two dry human skulls with no obvious temporomandibular joint pathology were used. Osteophytic lesions were simulated using three sizes of bone chips that were placed on the medial portion of anterior and superolateral aspects of the condyle. Osteolytic lesions were simulated making 1 and 2 mm holes using round burr in the central portion of anterior aspect and Lateral pole of the condyle. Panoramic radiographs were prepared with and without the lesions in place. These paired radiographs were digitized and digital- subtraction images of the original panoramic images were obtained. Eight observers evaluated 155 images of each modality for the presence or absence and the type of simulated lesions of the mandibular condyle. Sensitivity, specificity, reliability and measure of agreement were analyzed using kappa test and crossed tables and qualitative variables were assess by chi-square and fisher's Exact test. "nResults: Specificity of panoramic and DSR methods were 15.4% and 66.7% respectively. Sensitivity of panoramic and DSR methods were 61.1% and 80.6% for osteophytic lesions and 37.5% and 83.3% for Osteolytic lesions. The percentage of correct decisions made in DSR method was significantly more than conventional panoramic method (82.6% vs 41.9% (p<0.0001. "nConclusion: Based on the results of this study digital subtraction technique was significantly more accurate than the panoramic radiographs in detection of simulated lesions of the mandibular condyle.

  10. Automatic flow analysis of digital subtraction angiography using independent component analysis in patients with carotid stenosis.

    Directory of Open Access Journals (Sweden)

    Han-Jui Lee

    Full Text Available Current time-density curve analysis of digital subtraction angiography (DSA provides intravascular flow information but requires manual vasculature selection. We developed an angiographic marker that represents cerebral perfusion by using automatic independent component analysis.We retrospectively analyzed the data of 44 patients with unilateral carotid stenosis higher than 70% according to North American Symptomatic Carotid Endarterectomy Trial criteria. For all patients, magnetic resonance perfusion (MRP was performed one day before DSA. Fixed contrast injection protocols and DSA acquisition parameters were used before stenting. The cerebral circulation time (CCT was defined as the difference in the time to peak between the parietal vein and cavernous internal carotid artery in a lateral angiogram. Both anterior-posterior and lateral DSA views were processed using independent component analysis, and the capillary angiogram was extracted automatically. The full width at half maximum of the time-density curve in the capillary phase in the anterior-posterior and lateral DSA views was defined as the angiographic mean transient time (aMTT; i.e., aMTTAP and aMTTLat. The correlations between the degree of stenosis, CCT, aMTTAP and aMTTLat, and MRP parameters were evaluated.The degree of stenosis showed no correlation with CCT, aMTTAP, aMTTLat, or any MRP parameter. CCT showed a strong correlation with aMTTAP (r = 0.67 and aMTTLat (r = 0.72. Among the MRP parameters, CCT showed only a moderate correlation with MTT (r = 0.67 and Tmax (r = 0.40. aMTTAP showed a moderate correlation with Tmax (r = 0.42 and a strong correlation with MTT (r = 0.77. aMTTLat also showed similar correlations with Tmax (r = 0.59 and MTT (r = 0.73.Apart from vascular anatomy, aMTT estimates brain parenchyma hemodynamics from DSA and is concordant with MRP. This process is completely automatic and provides immediate measurement of quantitative peritherapeutic brain parenchyma

  11. Simultaneous optical digital half-subtraction and -addition using SOAs and a PPLN waveguide.

    Science.gov (United States)

    McGeehan, John E; Kumar, Saurabh; Willner, Alan E

    2007-04-30

    We demonstrate an optical half-subtracter and half-adder module that performs simultaneous bit-wise subtraction and addition of two 5 Gbit/s RZ data streams. We generate Borrow (/X*Y) and Difference/Sum (X plus sign in circleY, or XOR) outputs using cross-gain modulation (XGM) in two parallel SOAs. Taking advantage of the gain saturation inherent to SOAs, we generate two signals, /X*Y, and X*/Y, and combine them using a passive optical coupler to generate the XOR Difference/Sum output. We use difference-frequency-generation-based lambda-conversion in a PPLN waveguide to generate the Carry (X*Y) output. The PPLN waveguide allows bit-synchronous wavelength shifting, is wide-bandwidth, and offers no intrinsic chirp. Our module uses three active elements to perform simultaneous half-subtraction and addition, and carries a maximum power penalty of 1.0 dB.

  12. Digital subtraction radiographic analysis of the combination of bioabsorbable membrane and bovine morphogenetic protein pool in human periodontal infrabony defects

    Directory of Open Access Journals (Sweden)

    Maria do Carmo Machado Guimarães

    2010-08-01

    Full Text Available OBJECTIVES: This study assessed the bone density gain and its relationship with the periodontal clinical parameters in a case series of a regenerative therapy procedure. MATERIAL AND METHODS: Using a split-mouth study design, 10 pairs of infrabony defects from 15 patients were treated with a pool of bovine bone morphogenetic proteins associated with collagen membrane (test sites or collagen membrane only (control sites. The periodontal healing was clinically and radiographically monitored for six months. Standardized pre-surgical and 6-month postoperative radiographs were digitized for digital subtraction analysis, which showed relative bone density gain in both groups of 0.034 ± 0.423 and 0.105 ± 0.423 in the test and control group, respectively (p>0.05. RESULTS: As regards the area size of bone density change, the influence of the therapy was detected in 2.5 mm² in the test group and 2 mm² in the control group (p>0.05. Additionally, no correlation was observed between the favorable clinical results and the bone density gain measured by digital subtraction radiography (p>0.05. CONCLUSIONS: The findings of this study suggest that the clinical benefit of the regenerative therapy observed did not come with significant bone density gains. Long-term evaluation may lead to a different conclusions.

  13. [X-ray semiotics of sialolithiasis in functional digital subtraction sialography].

    Science.gov (United States)

    Iudin, L A; Kondrashin, S A; Afanas'ev, V V; Shchipskiĭ, A V

    1995-01-01

    Twenty-seven patients with sialolithiasis were examined using functional subtraction sialography developed by the authors. Differential diagnostic signs characterizing the degree of involvement of the salivary gland were defined. High efficacy of the method helps correctly plan the treatment strategy.

  14. Visualization of the renal venous system by renal arteriography with digital subtraction angiography

    International Nuclear Information System (INIS)

    Nagai, Jun

    1989-01-01

    The purpose of this study was to obtain vivid and precise images of intrarenal venous branching using DSA for renal arteriography. The type of system used was an ADAC DPS-4100C with 70-80 kVp, and 320 mA, 25-50 msec at 6 frames/sec. The duration was 10 sec and the matrix size was 512x512. In order to retain clear subtracted images of intrarenal venous branching with minimal noise the three frames were selected on the time-density curve of DSA: (Fig.3). 1) a frame on which renal arteries disappear (frame X), 2) the frame with highest renal venous density value as (frame Y), 3) the difference of the nephrogram density between X and Y frames in which only the density of the nephrogram decreases (frame Z). The mask image is the image subtracted by the equation of the weighted averaging method on X and Z frame and is subtracted from the image of Y frame in the final step. By this method, 40 kidneys in 36 patients were studied, and the intrarenal venous branches up to the interlobar vein was clearly demonstrated in 28 of these cases (70%). This method is useful to estimate the extent of intrarenal lesions and detect abnormal renal blood flow compared with conventional temporal subtraction method. (author)

  15. Comparison of Accuracy of Conventional Periapical Radiography and Direct Digital Subtractions Radiography with or without Image Enhancement in the Diagnosis of Density Changes

    Directory of Open Access Journals (Sweden)

    Tahmineh Razi

    2012-04-01

    Full Text Available Background and aims. In periapical radiographic technique, the changes will be visible only after considerable deposition or resorption while digital subtraction technique visualizes slight density changes. This study was aimed to compare visualization of density changes in conventional periapical radiographs and digital subtraction technique with or without image enhancement. Materials and methods. Three dry human mandibles with unspecified age and gender were selected. Conventional periapical and direct digital radiographs were taken from the anterior, and right and left posterior regions by step-wise placement of aluminum plates until the image of the plate was clearly visible. The radiographs taken with the direct digital technique were subtracted from the first radiograph using Photoshop software. Three observers evaluated the radiographs and the digital subtraction images with or without image enhancement. The density was recorded in each radiograph in which the image of the aluminum plate was completely visible. Results. In all mandibles, the differences in diagnosis of density changes between the conventional periapical radiographic technique and the direct digital subtraction radiographic technique with or without image enhancement were statistically significant irrespective of the region under study (p<0.001. There were no significant differences in the diagnosis of density changes in all the three mandibles in the left and right posterior regions between the two radiographic techniques. However, the differences in the anterior region were statistically significant (p<0.001. Conclusion. Direct digital subtraction radiographic technique with or without image enhancement is a more efficacious technique in exhibiting minor density changes compared to conventional periapical radiographic technique

  16. Pulmonary arteriography by digital subtraction angiographic method in cyanotic heart disease with pulmonary stenosis or pulmonary atresia

    International Nuclear Information System (INIS)

    Kobayashi, Junjiro; Hirose, Hajime; Nakano, Susumu

    1985-01-01

    Pulmonary arteriography was performed by digital subtraction angiographic (DSA) method in 10 patients with cyanotic heart disease associated with pulmonary stenosis or pulmonary atresia. Ten patients consisted of five patients with tetralogy of Fallot, three with single ventricle and pulmonary stenosis, and two with pseudotruncus arteriosus. Hepato-clavicular position was taken in four patients. Pulmonary artery and its main branches were opacified and recognized clearly, and their diameter could be measured accurately with a small amount of contrast medium. There was a good correlation between the diameter of pulmonary artery measured by DSA and that measured by conventional pulmonary arteriography. DSA is a useful method for evaluating the size and the stenosis of pulmonary artery especially in small cyanotic infants. (author)

  17. Influence of homeopathic treatment with comfrey on bone density around titanium implants: a digital subtraction radiography study in rats.

    Science.gov (United States)

    Sakakura, Celso Eduardo; Neto, Rubens Spin; Bellucci, Marina; Wenzel, Ann; Scaf, Gulnara; Marcantonio, Elcio

    2008-06-01

    The objective of this study was to evaluate the influence of homeopathic treatment with comfrey (Shymphytum officinalis 6CH) on radiographic bone density and area around titanium implants. Forty-eight rats were divided into two groups of 24 animals each: a control group (C) and a test group (SO). Each animal received one titanium micro-implant placed in the tibia. The animals in Group SO were subjected to 10 drops of comfrey 6CH per day mixed into their drinking water until the day of sacrifice. Eight animals of each group were sacrificed at 7, 14 and 28 days post-surgery, respectively. Standardized digital radiographs were obtained on the day of implant installation (baseline images) and on the day of sacrifice (final images). Digital subtraction of the two corresponding images was performed to evaluate changes in bone density and the area related to change around the implant between baseline and final images. Subtraction images demonstrated that a significant difference existed in mean shade of gray at 14 days post-surgery between Group SO (mean 175.3+/-14.4) and Group C (mean 146.2+/-5.2). Regarding the area in pixels corresponding to the bone gain in Group SO, the differences observed between the sacrifice periods and groups were only significant at 7 days sacrifice between Group SO (mean 171.2+/-21.9) and Group C (mean 64.5+/-60.4). Within the limits of this study, comfrey administration promotes an increase in radiographic bone density around titanium implants in the initial period of bone healing.

  18. Temporal Subtraction of Digital Breast Tomosynthesis Images for Improved Mass Detection

    National Research Council Canada - National Science Library

    Li, Christina M

    2007-01-01

    Digital breast tomosynthesis (DBT) strives to overcome the obstacles presented in conventional 2D mammography by taking multiple projections over a fixed angle and reconstructing volumetric data isolates overlying anatomy...

  19. Diagnostic yield and accuracy of CT angiography, MR angiography, and digital subtraction angiography for detection of macrovascular causes of intracerebral haemorrhage: Prospective, multicentre cohort study

    NARCIS (Netherlands)

    C.J.J. Van Asch (Charlotte J.J.); B.K. Velthuis (Birgitta K.); G.J.E. Rinkel (Gabriël J.E.); A. Algra (Ale); G.A.P. de Kort (G. A P); T.D. Witkamp (Theo); J.C.M. De Ridder (Johanna C.M.); K.M. Van Nieuwenhuizen (Koen M.); F.-E. De Leeuw (Frank-Erik); W.J. Schonewille (Wouter); P.L.M. de Kort (Paul); D.W.J. Dippel (Diederik); T.W.M. Raaymakers (Theodora W.M.); J. Hofmeijer; M.J.H. Wermer (Marieke); H. Kerkhoff (Henk); K. Jellema (Korné); I.M. Bronner (Irene M.); M.J.M. Remmers (Michel ); H.P. Bienfait (Henri); R.J.G.M. Witjes (Ron J.G.M.); J.P. Greving (Jacoba); C.J.M. Klijn (Catharina J.M.); H.F. de Leeuw (Frank); H.B. Boogaarts; E.J. van Dijk (Ewoud); W.J. Schonewille; W.M.J. Pellikaan; C. Puppels-De Waard; P.L.M. De Kort; J.P. Peluso; J. van Tuijl (Jordie); J. Hofmeijer; F.B.M. Joosten (Frank); D.W.J. Dippel (Diederik); L. Khajeh (Ladbon); T.W.M. Raaijmakers; M.J. Wermer; M.A.A. van Walderveen (Marianne); H. Kerkhoff; E. Zock; K. Jellema (Korné); G.J. Lycklama à Nijeholt (Geert); I.M. Bronner; M.J.M. Remmers; R.J.G.M. Witjes; H.P. Bienfait; K.E. Droogh-Greve; R. Donders (Rogier); V.I.H. Kwa; T.H.C.M.L. Schreuder (Tobien H. C. M. L.); C.L. Franke (Cees); J.S. Straver; C. Jansen; S.L.M. Bakker (Stef); C.C. Pleiter (C.); M.C. Visser; C.J.J. Van Asch; B.K. Velthuis (Birgitta); G.J.E. Rinkel (Gabriel); K.M. Van Nieuwenhuizen; C.J.M. Klijn (Catharina J.M.)

    2015-01-01

    textabstractStudy question What are the diagnostic yield and accuracy of early computed tomography (CT) angiography followed by magnetic resonance imaging/angiography (MRI/MRA) and digital subtraction angiography (DSA) in patients with non-traumatic intracerebral haemorrhage? Methods This

  20. Cost-Effectiveness of Magnetic Resonance Angiography Versus Intra-arterial Digital Subtraction Angiography to Follow-Up Patients With Coiled Intracranial Aneurysms

    NARCIS (Netherlands)

    Schaafsma, Joanna D.; Koffijberg, Hendrik; Buskens, Erik; Velthuis, Birgitta K.; van der Graaf, Yolanda; Rinkel, Gabriel J. E.

    Background and Purpose-To follow up patients with coiled intracranial aneurysms, magnetic resonance angiography (MRA) is a promising noninvasive alternative to current standard intra-arterial digital subtraction angiography (IA-DSA). MRA test results do not always concord with those of IA-DSA, and

  1. Cost-effectiveness of magnetic resonance angiography versus intra-arterial digital subtraction angiography to follow-up patients with coiled intracranial aneurysms

    NARCIS (Netherlands)

    Schaafsma, Joanna D.; Koffijberg, Hendrik; Buskens, Erik; Velthuis, Birgitta K.; van der Graaf, Yolanda; Rinkel, Gabriël J.E.

    Background and Purpose-: To follow up patients with coiled intracranial aneurysms, magnetic resonance angiography (MRA) is a promising noninvasive alternative to current standard intra-arterial digital subtraction angiography (IA-DSA). MRA test results do not always concord with those of IA-DSA, and

  2. Gadolinium-DTPA-enhanced and digitally subtracted magnetic resonance imaging of estrogen-induced pituitary lesions in rats: correlation with pituitary anatomy.

    Science.gov (United States)

    van Nesselrooij, J H; Szeverenyi, N M; Tillapaugh-Fay, G M; Hendriksen, F G

    1990-01-01

    Pituitary hypertrophy and tumors were induced in male Sprague Dawley rats using estradiol-17 beta. This tumor model generates a variety of pituitary lesions which are relevant to human pituitary disease. In order to characterize these lesions, gadolinium DTPA was injected intravenously into the tail vein of estrogen treated and control rats. High resolution T1-weighted MR images, pre- and postenhancement, were obtained at 8 different time points spanning 300 days following the subcutaneous implantation of the estrogen pellets. Images with 2-mm slice thickness were made with a 2 Telsa small-bore MR imaging system. Both normal and tumorous pituitaries were found to enhance with contrast agent, but contrast uptake was not uniform. Gd-DTPA distribution was sensitive to the different types of lesions generated in the course of this study. Digital subtraction of congruent images, pre- and postcontrast, provided difference images reflecting contrast concentration and allowed identification of subtle enhancement effects. Hypertrophic pituitaries displayed uptake of contrast, but the distribution of contrast agent was nonuniform and appeared mottled. A bright rim enhancement was often seen anterior to the pituitary gland, most likely arising from the oculomotor nerves and arachnoid. Histological slices in the same anatomical plane as the MR images were obtained on the animals allowing identification of individual lesions. Cystic areas within tumors were found to give strong contrast enhancement in less than five min postinjection. Solid and hemorrhagic areas of the pituitary tumor were hypo- to isointense relative to surrounding brain and did not take up contrast agent. Significant perfusion in these areas apparently does not occur.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. A feasibility study of projection-based energy weighting based on a photon-counting detector in contrast-enhanced digital subtraction mammography: a simulation study

    International Nuclear Information System (INIS)

    Choi, Sunghoon; Lee, Seungwan; Choi, Yuna; Kim, Heejoung

    2014-01-01

    Contrast media, such as iodine and gadolinium, are generally used in digital subtraction mammography to enhance the contrast between target and background materials. In digital subtraction mammography, where one image (with contrast medium) is subtracted from another (anatomical background) to facilitate visualization of the tumor structure, tumors can be more easily distinguished after the injection of a contrast medium. In order to have more an effective method to increase the contrast-to-noise ratio (CNR), we applied a projection-based energy-weighting method. The purpose of this study is to demonstrate the feasibility of using the projection-based energy-weighting method in digital subtraction mammography. Unlike some other previous studies, we applied the projection-based energy-weighting method to more practical mammography conditions by using the Monte Carlo method to simulate four different iodine solutions embedded in a breast phantom comprised of 50% adipose and 50% glandular tissues. We also considered an optimal tube voltage and anode/filter combination in digital iodine contrast media mammography in order to maximize the figure-of-merit (FOM). The simulated source energy was from 20 to 45 keV to prevent electronic noise and include the k-edge energy of iodine (33.2 keV). The results showed that the projection-based energy-weighting improved the CNR by factors of 1.05 - 1.86 compared to the conventionally integrated images. Consequently, the CNR of digital subtraction mammography images can be improved by using projection-based energy-weighting with photon-counting detectors.

  4. A feasibility study of projection-based energy weighting based on a photon-counting detector in contrast-enhanced digital subtraction mammography: a simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sunghoon; Lee, Seungwan; Choi, Yuna; Kim, Heejoung [Yonsei University, Wonju (Korea, Republic of)

    2014-06-15

    Contrast media, such as iodine and gadolinium, are generally used in digital subtraction mammography to enhance the contrast between target and background materials. In digital subtraction mammography, where one image (with contrast medium) is subtracted from another (anatomical background) to facilitate visualization of the tumor structure, tumors can be more easily distinguished after the injection of a contrast medium. In order to have more an effective method to increase the contrast-to-noise ratio (CNR), we applied a projection-based energy-weighting method. The purpose of this study is to demonstrate the feasibility of using the projection-based energy-weighting method in digital subtraction mammography. Unlike some other previous studies, we applied the projection-based energy-weighting method to more practical mammography conditions by using the Monte Carlo method to simulate four different iodine solutions embedded in a breast phantom comprised of 50% adipose and 50% glandular tissues. We also considered an optimal tube voltage and anode/filter combination in digital iodine contrast media mammography in order to maximize the figure-of-merit (FOM). The simulated source energy was from 20 to 45 keV to prevent electronic noise and include the k-edge energy of iodine (33.2 keV). The results showed that the projection-based energy-weighting improved the CNR by factors of 1.05 - 1.86 compared to the conventionally integrated images. Consequently, the CNR of digital subtraction mammography images can be improved by using projection-based energy-weighting with photon-counting detectors.

  5. A quantitative study of bone repair after endodontic therapy on digital subtraction radiography

    International Nuclear Information System (INIS)

    Kim, Jae Duk

    1997-01-01

    This study was performed to prepare the quantitative method of judging the sensitive prognosis of chronic apical periodontitis as early as possible. The subjects were 25 cases with periapical radiolucencies of which were treated with endodontic treatment. Serial radiographs were taken by standardized method longitudinally. The density slice function of digital radiographic system were employed for quantitative and longitudinal assessment of the radiolucent area and the condensing osteitis simultaneously. Obtained results were as follows: 1. The amount of bone repair after endodontic treatment could be detected quantitatively by the density slice function of digital radiographic system. 2. Within the 6-week period after root canal filling, the prognosis could be evaluated by assessment both radiolucent area and condensing osteitis on digital radiographic system. 3. The pattern of bone repair showed peripheral type in most cases from the 6th week after root canal filling. 4. In longitudinal change, bone repair showed two patterns; the succeeding reduction of radiolucent area showing the increase of condensing osteitis in size till 6th week and following by static state or reduction tendency and the reduction following the initial increase of both areas. 5. Cases with pulpitis by trauma showed initial increase of condensing osteitis at 2nd week, marked reduction of radiolucent area and condensing osteitis at 6th week, and approximately normal bone state at 8th week after root canal filling.

  6. A quantitative study of bone repair after endodontic therapy on digital subtraction radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Duk [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Chosun University, Kwangju (Korea, Republic of)

    1997-08-15

    This study was performed to prepare the quantitative method of judging the sensitive prognosis of chronic apical periodontitis as early as possible. The subjects were 25 cases with periapical radiolucencies of which were treated with endodontic treatment. Serial radiographs were taken by standardized method longitudinally. The density slice function of digital radiographic system were employed for quantitative and longitudinal assessment of the radiolucent area and the condensing osteitis simultaneously. Obtained results were as follows: 1. The amount of bone repair after endodontic treatment could be detected quantitatively by the density slice function of digital radiographic system. 2. Within the 6-week period after root canal filling, the prognosis could be evaluated by assessment both radiolucent area and condensing osteitis on digital radiographic system. 3. The pattern of bone repair showed peripheral type in most cases from the 6th week after root canal filling. 4. In longitudinal change, bone repair showed two patterns; the succeeding reduction of radiolucent area showing the increase of condensing osteitis in size till 6th week and following by static state or reduction tendency and the reduction following the initial increase of both areas. 5. Cases with pulpitis by trauma showed initial increase of condensing osteitis at 2nd week, marked reduction of radiolucent area and condensing osteitis at 6th week, and approximately normal bone state at 8th week after root canal filling.

  7. Comparison of spiral CT angiography vs digital subtraction angiography in the evaluation of living kidney donors

    Directory of Open Access Journals (Sweden)

    Santosh Kumar

    2002-01-01

    Full Text Available Recent reports suggest that spiral computed tomographic (CT angiography could replace conventional angiogra-phy and intravenous urography (IVU for the assessment of potential live kidney donors. The purpose of this study was to assess the accuracy of spiral CT in kidney donor workup. 10 consecutive renal donors had IVU, percutane-ous transfemoral selective renal angiography and spiral CT angiography between January and March 2001. The spiral CT and renal angiograms were assessed independ-ently by two radiologists. The number of renal arteries, pres-ence or absence of renal artery stenoses and associated parenchymal abnormalities were assessed. A total of 27 renal arteries were detected. Transverse scans viewed in a tine loop format with maximum intensity projection and shaded surface display detected all 27 vessels. All 27 ves-sels were detected by conventional catheter angiography. A simple renal cyst was noted in both spiral CT and con-ventional angiogram. Venous anatomy including a retroaortic renal vein was visualized in spiral CT angiogram but not visualized by conventional angiography. Spiral CT angiography performed as an outpatient procedure is less invasive, less expensive, and provides good images of the arterial and venous anatomy in addition to the visualiza-tion of the other abdominal viscera. A plain X-ray of the abdomen was taken 15 rains after injection of contrast to acquire an IVU like image. Spiral CT angiography has the potential to replace conventional catheter angiography and IVU in the assessment of renal donors.

  8. Radiological investigation of renovascular hypertension from IVU to digital subtraction angiography. A critical evaluation

    International Nuclear Information System (INIS)

    Amiel, M.; Froment, A.; Pinet, F.; Huguet, M.

    1986-01-01

    For the last 20 years, the value of radiology in renovascular hypertension (RVH) is well established from diagnostic and therapeutic points of view. However things are changing now due to a better appraisal of the incidence of RVH, new antihypertensive drugs, and new radiological procedures (digital angiography, percutaneous transluminal angioplasty). The approach now takes in account the mode of imaging for a better evaluation of the renal artery stenosis and costs of the proceedings as well. Finally a new strategy has been set up for RVH patients management [fr

  9. Intra-aneurysmal flow patterns: illustrative comparison among digital subtraction angiography, optical flow, and computational fluid dynamics.

    Science.gov (United States)

    Brina, O; Ouared, R; Bonnefous, O; van Nijnatten, F; Bouillot, P; Bijlenga, P; Schaller, K; Lovblad, K-O; Grünhagen, T; Ruijters, D; Pereira, V Mendes

    2014-12-01

    Digital subtraction angiography is the gold standard vascular imaging and it is used for all endovascular treatment of intracranial anerysms. Optical flow imaging has been described as a potential method to evaluate cerebral hemodynamics through DSA. In this study, we aimed to compare the flow patterns measured during angiography, by using an optical flow method, with those measured by using computational fluid dynamics in intracranial aneurysms. A consecutive series of 21 patients harboring unruptured saccular intracranial aneurysms who underwent diagnostic angiography before treatment was considered. High-frame-rate digital subtraction angiography was performed to obtain an intra-aneurysmal velocity field by following the cardiac-modulated contrast wave through the vascular structures by using optical flow principles. Additionally, computational fluid dynamics modeling was performed for every case by using patient-specific inlet-boundary conditions measured with the optical flow method from both DSA and 3D rotational angiography datasets. Three independent observers compared qualitatively both the inflow direction and the apparent recirculation in regular DSA, optical flow images, and computational fluid dynamics flow patterns for each patient; κ statistics were estimated. We included 21 patients. In 14 of these 21, the flow patterns were conclusive and matching between the optical flow images and computational fluid dynamics within the same projection view (κ = .91). However, in only 8 of these 14 patients the optical flow images were conclusive and matching regular DSA images (observer κ = 0.87). In 7 of the 21 patients, the flow patterns in the optical flow images were inconclusive, possibly due to improper projection angles. The DSA-based optical flow technique was considered qualitatively consistent with computational fluid dynamics outcomes in evaluating intra-aneurysmal inflow direction and apparent recirculation. Moreover, the optical flow technique

  10. Subtractive Leadership

    Science.gov (United States)

    Larwin, K. H.; Thomas, Eugene M.; Larwin, David A.

    2015-01-01

    This paper introduces a new term and concept to the leadership discourse: Subtractive Leadership. As an extension of the distributive leadership model, the notion of subtractive leadership refers to a leadership style that detracts from organizational culture and productivity. Subtractive leadership fails to embrace and balance the characteristics…

  11. Suppression of high-density artefacts in x-ray CT images using temporal digital subtraction with application to cryotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Baissalov, R.; Sandison, G.A.; Rewcastle, J.C. [Department of Medical Physics, Tom Baker Cancer Center, Calgary, Canada, T2N 4N2 2 Department of Physics and Astronomy, University of Calgary, Calgary T2N 2N4 (Canada); Donnelly, B.J. [Department of Surgery, Tom Baker Cancer Center, Calgary, Canada, T2N 4N2 4 Department of Surgery, Foothills Hospital, Calgary T2N 2T7 (Canada); Saliken, J.C. [Department of Surgery, Tom Baker Cancer Center, Calgary T2N 4N2 (Canada); Department of Diagnostic Imaging, Foothills Hospital, Calgary T2N 2T7 (Canada); McKinnon, J.G. [Department of Surgery, Foothills Hospital, Calgary T2N 2T7 (Canada); Muldrew, K. [Department of Surgery, Faculty of Medicine, University of Calgary, Calgary T2N 2T7 (Canada)

    2000-05-01

    Image guidance in cryotherapy is usually performed using ultrasound. Although not currently in routine clinical use, x-ray CT imaging is an alternative means of guidance that can display the full 3D structure of the iceball, including frozen and unfrozen regions. However, the quality of x-ray CT images is compromised by the presence of high-density streak artefacts. To suppress these artefacts we applied temporal digital subtraction (TDS). This TDS method has the added advantage of improving the grey-scale contrast between frozen and unfrozen tissue in the CT images. Two sets of CT images were taken of a phantom material, cryoprobes and a urethral warmer (UW) before and during the cryoprobe freeze cycle. The high-density artefacts persisted in both image sets. TDS was performed on these two image sets using the corresponding mask image of unfrozen material and the same geometrical configuration of the cryoprobes and the UW. The resultant difference image had a significantly reduced artefact content. Thus TDS can be used to significantly suppress or eliminate high-density CT streak artefacts without reducing the metallic content of the cryoprobes. In vivo study needs to be conducted to establish the utility of this TDS procedure for CT assisted prostate or liver cryotherapy. Applying TDS in x-ray CT guided cryotherapy will facilitate estimation of the number and location of all frozen and unfrozen regions, potentially making cryotherapy safer and less operator dependent. (author)

  12. Suppression of high-density artefacts in x-ray CT images using temporal digital subtraction with application to cryotherapy

    International Nuclear Information System (INIS)

    Baissalov, R.; Sandison, G.A.; Rewcastle, J.C.; Donnelly, B.J.; Saliken, J.C.; McKinnon, J.G.; Muldrew, K.

    2000-01-01

    Image guidance in cryotherapy is usually performed using ultrasound. Although not currently in routine clinical use, x-ray CT imaging is an alternative means of guidance that can display the full 3D structure of the iceball, including frozen and unfrozen regions. However, the quality of x-ray CT images is compromised by the presence of high-density streak artefacts. To suppress these artefacts we applied temporal digital subtraction (TDS). This TDS method has the added advantage of improving the grey-scale contrast between frozen and unfrozen tissue in the CT images. Two sets of CT images were taken of a phantom material, cryoprobes and a urethral warmer (UW) before and during the cryoprobe freeze cycle. The high-density artefacts persisted in both image sets. TDS was performed on these two image sets using the corresponding mask image of unfrozen material and the same geometrical configuration of the cryoprobes and the UW. The resultant difference image had a significantly reduced artefact content. Thus TDS can be used to significantly suppress or eliminate high-density CT streak artefacts without reducing the metallic content of the cryoprobes. In vivo study needs to be conducted to establish the utility of this TDS procedure for CT assisted prostate or liver cryotherapy. Applying TDS in x-ray CT guided cryotherapy will facilitate estimation of the number and location of all frozen and unfrozen regions, potentially making cryotherapy safer and less operator dependent. (author)

  13. Nonlinear Geometric Warping of the Mask Image: A New Method for Reducing Misregistration Artifacts in Digital Subtraction Angiography

    International Nuclear Information System (INIS)

    Hayashi, Nobushige; Sakai, Toyohiko; Kitagawa, Manabu; Inagaki, Rika; Sadato, Norihiro; Ishii, Yasushi; Nishimoto, Yasuhiro; Tanaka, Masato; Fukushima, Tetsuya; Komuro, Hiroyuki; Ogura, Hisakazu; Kobayashi, Hidenori; Kubota, Toshihiko

    1998-01-01

    Purpose: Misregistration artifact is the major cause of image degradation in digital subtraction angiography (DSA). The purpose of this study was to evaluate the efficacy of a newly developed nonlinear geometric warping method to reduce misregistration artifact in DSA. Methods: The processing of the images was carried out on a workstation with a fully automatic computerized program. After making differential images with a lapracian filter, 49 regions of interest (ROIs) were set in the image to be processed. Each ROI of the live image scanned the corresponding ROI of the mask image searching for the best position to match itself. Each pixel of the mask image was shifted individually following the data calculated from the shifts of the ROIs. Five radiologists compared the images produced by the conventional parallel shift technique and those processed with this new method in 16 series of cerebral DSA. Results: In 14 of 16 series (88%), more radiologists judged the images processed with the new method to be better in quality. Small arteries near the skull base and veins of low density were clearly visualized in the images processed by the new method. Conclusion: This newly proposed method could be a simple and practical way to automatically reduce misregistration artifacts in DSA

  14. Variations and Anomalies of the circle of Willis in Korean: Cerebral digital subtraction angiogram studies in 200 case

    International Nuclear Information System (INIS)

    Lee, Ouk; Chung, Gyoo Sik; Kim, So Sun; Huh, Jin Do; Kim, Ho Joon; Joh, Young Duk

    1989-01-01

    In order to evaluate the variations of the circle of Willis in Korean population, digital subtraction angiograms in 200 cases were retrospectively analyzed. There was non-visualization of the anterior communicating artery and the posterior communicating artery in 41 cases and this was the most common type 4 vessel cerebral angiogram (20.5%). Unilateral or bilateral non-visualization of the posterior communicating artery was noted in 40 case (20%). The fetal origin of the posterior cerebral artery from the internal carotid artery was seen in 22 cases (11%). In 20 out of 22 cases, there were non-visualization of either the anterior communicating or posterior communicating artery. Visualization of the anterior communicating artery was noted in 102 cases (51%) and of the posterior communicating artery in 87 cases (43.5%). Hypoplasia of the anterior cerebral artery was noted in 24 cases (12%). Non- visualization of the anterior communicating artery or unilateral posterior communicating artery is noted in 16 cases (8%). Non- visualization of the anterior communicating artery was seen in 14 cases (7%). The most common type in appearance of the basilar artery variation was straight type (Type 1: 51%) and the bifurcation of the basilar artery was most commonly located above the posterior clinoid process of the dorsum sellae (58%) on vertebral angiogram

  15. A comparison between ultrasonography and mammography, computed tomography and digital subtraction angiography for the detection of breast cancers

    Energy Technology Data Exchange (ETDEWEB)

    Tohnosu, Noriyuki; Okuyama, Kazuaki; Koide, Yoshio (Chiba Univ. (Japan). School of Medicine) (and others)

    1993-08-01

    Ultrasound (US) was compared with mammography (MMG), computed tomography (CT), and digital subtraction angiography (DSA) in its effectiveness to detect breast cancer masses and metastatic axillary nodes. Forty-seven breast cancer patients who all underwent MMG, US, CT, and DSA preoperatively in our institution between 1986 and 1990 were studied. US was able to detect tumors in all cases regardless of tumor size, whereas DSA detected T1-size tumors and MMG detected T2-size tumors in 40% and 64.7% of cases, respectively, being specifically inferior to US. It was found that MMG was least likely to detect papillotubular carcinoma, although microcalcification alone without a tumor mass on MMG improved detectability from 46.2% to 76.9%, according to the histological type. CT was found to be most sensitive to axillary node metastases (81.8%), followed by US (72.7%), but DSA was significantly unfavorable (42.9%). Thus, we concluded that US was superior to MMG, CT, and DSA for detecting breast cancer masses, but that CT was more advantageous than US, while DSA was of little value for evaluating axillary nodal status. (author).

  16. Correlation Between Contrast Time-Density Time on Digital Subtraction Angiography and Flow: An in Vitro Study.

    Science.gov (United States)

    Brunozzi, Denise; Shakur, Sophia F; Ismail, Rahim; Linninger, Andreas; Hsu, Chih-Yang; Charbel, Fady T; Alaraj, Ali

    2018-02-01

    Digital subtraction angiography (DSA) provides an excellent anatomic characterization of cerebral vasculature, but hemodynamic assessment is often qualitative and subjective. Various clinical algorithms have been produced to semiquantify flow from the data obtained from DSA, but few have tested them against reliable flow values. An arched flow model was created and injected with contrast material. Seventeen injections were acquired in anterior-posterior and lateral DSA projections, and 4 injections were acquired in oblique projection. Image intensity change over the angiogram cycle of each DSA run was analyzed through a custom MATLAB code. Time-density plots obtained were divided into 3 components (time-density times, TDTs): TDT 10%-100% (time needed for contrast material to change image intensity from 10% to 100%), TDT 100%-10% (time needed for contrast material to change image intensity from 100% to 10%), and TDT 25%-25% (time needed for contrast material to change from 25% image intensity to 25%). Time-density index (TDI) was defined as model cross-sectional area to TDT ratio, and it was measured against different flow rates. TDI 10%-100% , TDI 100%-10% , and TDI 25%-25% all correlated significantly with flow (P flow. TDI on DSA correlates significantly with flow. Although in vitro studies might overlook conditions that occur in patients, this method appears to correlate with the flow and could offer a semiquantitative method to evaluate the cerebral blood flow. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Digital tomosynthesis—a new lease of life for the intravenous urogram?

    Science.gov (United States)

    Wells, I T P; Raju, V M; Rowberry, B K; Johns, S; Freeman, S J; Wells, I P

    2011-01-01

    Objectives Digital tomosynthesis is a new digital technique based on conventional X-ray tomography. It acquires multiple low-dose projections during a single sweep of the X-ray tube, which are reassembled to provide high-resolution slices at different depths. Suggested uses include visualisation of pulmonary nodules, mammography, angiography, dental imaging and delineation of fractures. This study aims to evaluate its potential role as part of an intravenous urogram (IVU) by assessing the diagnostic quality in imaging the kidneys in clinical practice. Methods 100 renal units from consecutive traditional IVU studies were retrospectively compared with 101 renal units imaged using digital tomosynthesis. These were scored for visualisation of the renal outline and collecting system, presence of a renal cyst or mass and overall diagnostic quality. Radiation doses were calculated. Results 46.5% of traditional IVUs were found to be of diagnostic quality. The IVUs with digital tomosynthesis were of diagnostic quality in 95.5%. This represents a highly statistically significant difference (pIVU, and significantly reduces radiation. It also offers considerable advantages in ease and speed of imaging. For these reasons, in any situation where IVU is still being used to assess the kidneys, digital tomosynthesis is likely to be of considerable benefit in improving diagnostic quality. PMID:21511750

  18. Digital tomosynthesis--a new lease of life for the intravenous urogram?

    Science.gov (United States)

    Wells, I T P; Raju, V M; Rowberry, B K; Johns, S; Freeman, S J; Wells, I P

    2011-05-01

    Digital tomosynthesis is a new digital technique based on conventional X-ray tomography. It acquires multiple low-dose projections during a single sweep of the X-ray tube, which are reassembled to provide high-resolution slices at different depths. Suggested uses include visualisation of pulmonary nodules, mammography, angiography, dental imaging and delineation of fractures. This study aims to evaluate its potential role as part of an intravenous urogram (IVU) by assessing the diagnostic quality in imaging the kidneys in clinical practice. 100 renal units from consecutive traditional IVU studies were retrospectively compared with 101 renal units imaged using digital tomosynthesis. These were scored for visualisation of the renal outline and collecting system, presence of a renal cyst or mass and overall diagnostic quality. Radiation doses were calculated. 46.5% of traditional IVUs were found to be of diagnostic quality. The IVUs with digital tomosynthesis were of diagnostic quality in 95.5%. This represents a highly statistically significant difference (pIVU, and significantly reduces radiation. It also offers considerable advantages in ease and speed of imaging. For these reasons, in any situation where IVU is still being used to assess the kidneys, digital tomosynthesis is likely to be of considerable benefit in improving diagnostic quality.

  19. Follow-up after embolization of ruptured intracranial aneurysms: a prospective comparison of two-dimensional digital subtraction angiography, three-dimensional digital subtraction angiography, and time-of-flight magnetic resonance angiography.

    Science.gov (United States)

    Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2012-11-01

    To prospectively compare of the diagnostic value of digital subtraction angiography (DSA) and time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. Seventy-two consecutive patients were examined 3 months after the embolization. The index tests included: two-dimensional DSA (2D-DSA), three-dimensional DSA (3D-DSA), and TOF-MRA. The reference test was a retrospective consensus between 2D-DSA images, 3D-DSA images, and source rotational DSA images. The evaluation included: detection of the residual flow, quantification of the flow, and validity of the decision regarding retreatment. Intraobserver agreement and interobserver agreement were determined. The sensitivity and specificity of residual flow detection ranged from 84.6 % (2D-DSA and TOF-MRA) to 92.3 % (3D-DSA) and from 91.3 % (TOF-MRA) to 97.8 % (3D-DSA), respectively. The accuracy of occlusion degree evaluation ranged from 0.78 (2D-DSA) to 0.92 (3D-DSA, Cohen's kappa). The 2D-DSA method presented lower performance in the decision on retreatment than 3D-DSA (P < 0.05, ROC analysis). The intraobserver agreement was very good for all techniques (κ = 0.80-0.97). The interobserver agreement was moderate for TOF-MRA and very good for 2D-DSA and 3D-DSA (κ = 0.72-0.94). Considering the invasiveness of DSA and the minor difference in the diagnostic performance between 3D-DSA and TOF-MRA, the latter method should be the first-line modality for follow-up after aneurysm embolization.

  20. Follow-up after embolization of ruptured intracranial aneurysms: A prospective comparison of two-dimensional digital subtraction angiography, three-dimensional digital subtraction angiography, and time-of-flight magnetic resonance angiography

    International Nuclear Information System (INIS)

    Serafin, Zbigniew; Strzesniewski, Piotr; Lasek, Wladyslaw; Beuth, Wojciech

    2012-01-01

    To prospectively compare of the diagnostic value of digital subtraction angiography (DSA) and time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. Seventy-two consecutive patients were examined 3 months after the embolization. The index tests included: two-dimensional DSA (2D-DSA), three-dimensional DSA (3D-DSA), and TOF-MRA. The reference test was a retrospective consensus between 2D-DSA images, 3D-DSA images, and source rotational DSA images. The evaluation included: detection of the residual flow, quantification of the flow, and validity of the decision regarding retreatment. Intraobserver agreement and interobserver agreement were determined. The sensitivity and specificity of residual flow detection ranged from 84.6 % (2D-DSA and TOF-MRA) to 92.3 % (3D-DSA) and from 91.3 % (TOF-MRA) to 97.8 % (3D-DSA), respectively. The accuracy of occlusion degree evaluation ranged from 0.78 (2D-DSA) to 0.92 (3D-DSA, Cohen's kappa). The 2D-DSA method presented lower performance in the decision on retreatment than 3D-DSA (P < 0.05, ROC analysis). The intraobserver agreement was very good for all techniques (κ = 0.80-0.97). The interobserver agreement was moderate for TOF-MRA and very good for 2D-DSA and 3D-DSA (κ = 0.72-0.94). Considering the invasiveness of DSA and the minor difference in the diagnostic performance between 3D-DSA and TOF-MRA, the latter method should be the first-line modality for follow-up after aneurysm embolization. (orig.)

  1. Follow-up after embolization of ruptured intracranial aneurysms: A prospective comparison of two-dimensional digital subtraction angiography, three-dimensional digital subtraction angiography, and time-of-flight magnetic resonance angiography

    Energy Technology Data Exchange (ETDEWEB)

    Serafin, Zbigniew; Strzesniewski, Piotr; Lasek, Wladyslaw [Nicolaus Copernicus University, Collegium Medicum, Department of Radiology and Diagnostic Imaging, Bydgoszcz (Poland); Beuth, Wojciech [Nicolaus Copernicus University, Collegium Medicum, Department of Neurosurgery and Neurotraumatology, Bydgoszcz (Poland)

    2012-11-15

    To prospectively compare of the diagnostic value of digital subtraction angiography (DSA) and time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. Seventy-two consecutive patients were examined 3 months after the embolization. The index tests included: two-dimensional DSA (2D-DSA), three-dimensional DSA (3D-DSA), and TOF-MRA. The reference test was a retrospective consensus between 2D-DSA images, 3D-DSA images, and source rotational DSA images. The evaluation included: detection of the residual flow, quantification of the flow, and validity of the decision regarding retreatment. Intraobserver agreement and interobserver agreement were determined. The sensitivity and specificity of residual flow detection ranged from 84.6 % (2D-DSA and TOF-MRA) to 92.3 % (3D-DSA) and from 91.3 % (TOF-MRA) to 97.8 % (3D-DSA), respectively. The accuracy of occlusion degree evaluation ranged from 0.78 (2D-DSA) to 0.92 (3D-DSA, Cohen's kappa). The 2D-DSA method presented lower performance in the decision on retreatment than 3D-DSA (P < 0.05, ROC analysis). The intraobserver agreement was very good for all techniques ({kappa} = 0.80-0.97). The interobserver agreement was moderate for TOF-MRA and very good for 2D-DSA and 3D-DSA ({kappa} = 0.72-0.94). Considering the invasiveness of DSA and the minor difference in the diagnostic performance between 3D-DSA and TOF-MRA, the latter method should be the first-line modality for follow-up after aneurysm embolization. (orig.)

  2. An automatic fuzzy-based multi-temporal brain digital subtraction angiography image fusion algorithm using curvelet transform and content selection strategy.

    Science.gov (United States)

    Momeni, Saba; Pourghassem, Hossein

    2014-08-01

    Recently image fusion has prominent role in medical image processing and is useful to diagnose and treat many diseases. Digital subtraction angiography is one of the most applicable imaging to diagnose brain vascular diseases and radiosurgery of brain. This paper proposes an automatic fuzzy-based multi-temporal fusion algorithm for 2-D digital subtraction angiography images. In this algorithm, for blood vessel map extraction, the valuable frames of brain angiography video are automatically determined to form the digital subtraction angiography images based on a novel definition of vessel dispersion generated by injected contrast material. Our proposed fusion scheme contains different fusion methods for high and low frequency contents based on the coefficient characteristic of wrapping second generation of curvelet transform and a novel content selection strategy. Our proposed content selection strategy is defined based on sample correlation of the curvelet transform coefficients. In our proposed fuzzy-based fusion scheme, the selection of curvelet coefficients are optimized by applying weighted averaging and maximum selection rules for the high frequency coefficients. For low frequency coefficients, the maximum selection rule based on local energy criterion is applied to better visual perception. Our proposed fusion algorithm is evaluated on a perfect brain angiography image dataset consisting of one hundred 2-D internal carotid rotational angiography videos. The obtained results demonstrate the effectiveness and efficiency of our proposed fusion algorithm in comparison with common and basic fusion algorithms.

  3. Clinical and radiological of acute ischemic stroke patients without angiographic occlusion on digital subtraction angiogram. A pooled analysis of case series

    International Nuclear Information System (INIS)

    Shah, Qaisar A.; Memon Zeeshan, Muhammad; Vazquez, Gabriela; Suri, M. Fareed K.; Hussein, Haitham M.; Qureshi, Adnan I.; Mohammad, Yousef M.

    2008-01-01

    Approximately 20-30% of the patients with acute ischemic stroke do not have any occlusion demonstrated on initial digital subtraction angiography (DSA). We sought to determine the risk and rates of cerebral infarction and favorable neurological outcome in this group of acute ischemic stroke patients. Patients were identified from a prospectively maintained stroke database and from literature search of MEDLINE, PubMed, and Cochrane databases. All patients had initial neurological assessment on National Institutes of Health Stroke Scale (NIHSS). Patients then underwent DSA after initial head computed tomography (CT) scans. Follow-up radiological assessment at 24-72 h was performed with CT and magnetic resonance imaging scans. Association of stroke risk factors with clinical and radiological outcomes was estimated. A total of 81 patients was analyzed (mean age 63 years; 28 were women). The median NIHSS score was 8 (range 2-25). None of the patients received either intravenous or intra-arterial thrombolytic. Cerebral infarction was detected in 62 (76%) of the 81 patients. Twenty-four to 48-h NIHSS was available for 51 patients only. Neurological improvement was observed in 22 (43%) of the 51 patients. Favorable outcome ascertained at 3-month follow-up was seen in 48 (59%) of the 81 patients. After adjusting for age, sex, and baseline NIHSS, male patients [odds ratio (OR) 4.5 (1.4-14.3), p value=0.01] and patients with age≥ =65 [OR 4.3 (1.2-16.2), p value=0.03] have a higher risk of cerebral infarcts on the follow-up imaging. Similarly, patients who presented with 10 NIHSS [OR 0.21 (0.08-0.61), p value=0.004]. Ischemic stroke patients without arterial occlusion on DSA have a higher risk of cerebral infarction and disability particularly in men, patients over 65 years of age and with NIHSS≥=10. The cause of infarction may have been arterial obstruction with spontaneous recanalization or small vessel occlusion not visible on DSA

  4. Extrahepatic Arteries Originating from Hepatic Arteries: Analysis Using CT During Hepatic Arteriography and Visualization on Digital Subtraction Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Ozaki, Kumi, E-mail: ozakik-rad@umin.org [Kanazawa University Graduate School of Medical Science, Department of Radiology (Japan); Kobayashi, Satoshi [Kanazawa University Graduate School of Medical Science, Department of Quantum Medicine Technology (Japan); Matsui, Osamu; Minami, Tetsuya; Koda, Wataru; Gabata, Toshifumi [Kanazawa University Graduate School of Medical Science, Department of Radiology (Japan)

    2017-06-15

    PurposeTo investigate the prevalence and site of origin of extrahepatic arteries originating from hepatic arteries on early phase CT during hepatic arteriography (CTHA) was accessed. Visualization of these elements on digital subtraction hepatic angiography (DSHA) was assessed using CTHA images as a gold standard.Materials and MethodsA total of 943 patients (mean age 66.9 ± 10.3 years; male/female, 619/324) underwent CTHA and DSHA. The prevalence and site of origin of extrahepatic arteries were accessed using CTHA and visualized using DSHA.ResultsIn 924 (98.0%) patients, a total of 1555 extrahepatic branches, representing eight types, were found to originate from hepatic arteries on CTHA. CTHA indicated the following extrahepatic branch prevalence rates: right gastric artery, 890 (94.4%); falciform artery, 386 (40.9%); accessory left gastric artery, 161 (17.1%); left inferior phrenic artery (IPA), 43 (4.6%); posterior superior pancreaticoduodenal artery, 33 (3.5%); dorsal pancreatic artery, 26 (2.8%); duodenal artery, 12 (1.3%); and right IPA, 4 (0.4%). In addition, 383 patients (40.6%) had at least one undetectable branch on DSHA. The sensitivity, specificity, and accuracy of visualization on DSHA were as follows: RGA, 80.0, 86.8, and 80.4%; falciform artery, 53.9, 97.7, and 80.0%; accessory LGA, 64.6, 98.6, and 92.3%; left IPA, 76.7, 99.8, and 98.7%; PSPDA, 100, 99.7, and 99.9%; dorsal pancreatic artery, 57.7, 100, and 98.8%; duodenal artery, 8.3, 99.9, and 98.7%; and right IPA, 0, 100, and 99.6%, respectively.ConclusionExtrahepatic arteries originating from hepatic arteries were frequently identified on CTHA images. These arteries were frequently overlooked on DSHA.

  5. CT Angiography of Peripheral Arterial Disease by 256-Slice Scanner: Accuracy, Advantages and Disadvantages Compared to Digital Subtraction Angiography.

    Science.gov (United States)

    Mishra, Atul; Jain, Narendra; Bhagwat, Anand

    2017-07-01

    Peripheral arterial occlusive disease (PAOD) may cause disabling claudication or critical limb ischemia. Multidetector computed tomography (CT) technology has evolved to the level of 256-slice CT scanners which has significantly improved the spatial and temporal resolution of the images. This has provided the capability of chasing the contrast bolus at a fast speed enabling angiographic imaging of long segments of the body. These images can be reconstructed in various planes and various modes for detailed analysis of the peripheral vascular diseases which helps in making treatment decision. The aim of this retrospective study was to compare the CT angiograms (CTAs) of all cases of PAOD done by 256-slice CT scanner at a tertiary care vascular center and comparing these images with the digital subtraction angiograms (DSAs) of these patients. The retrospective study included 53 patients who underwent both CTA and DSA at our center over a period of 3 years from March 2013 to March 2016. The CTA showed high sensitivity (93%) and specificity (92.7%) for overall assessment of degree of stenosis in a vascular segment in cases of aortic and lower limb occlusive disease. The assessment of lesions of infrapopliteal segment was comparatively inferior (sensitivity 91.6%, accuracy 73.3%, and positive predictive value 78.5%), more so in the presence of significant calcification. The advantages of CTA were its noninvasive nature, ability to image large area of body, almost no adverse effects to the patients, and better assessment of vessel wall disease. However, the CTA assessment of collaterals was inferior with a sensitivity of only 62.7% as compared to DSA. Overall, 256-slice CTA provides fast and accurate imaging of vascular tree which can restrict DSA only in few selected cases as a problem-solving tool where clinico-radiological mismatch is present.

  6. Utility of digital subtraction angiography-based collateral evaluation in medically treated acute symptomatic basilar artery stenosis.

    Science.gov (United States)

    Lee, W-J; Jung, K-H; Ryu, Y J; Kim, J-M; Lee, S-T; Chu, K; Kim, M; Lee, S K; Roh, J-K

    2017-09-01

    Although a stroke from atherosclerosis in the basilar artery (BA) often presents with mild initial stroke severity, it has heterogeneous clinical courses. We investigated the efficacy of digital subtraction angiography (DSA)-based collateral perfusion evaluation in association with long-term outcomes of medically treated symptomatic basilar artery stenosis. From a registry database of all consecutive patients with stroke, we included 98 medically treated patients (due to mild initial stroke severity) [National Institute of Health Stroke Scale (NIHSS) scores ≤ 4; symptomatic basilar artery stenosis, 70-99%] with available initial diagnostic DSA. Basilar collateral scoring was performed via the DSA, using a modified version of the American Society of Interventional and Therapeutic Neuroradiology/Society of Interventional Radiology grading system in both the superior cerebellar artery and anterior/posterior-inferior cerebellar artery territories (score 0-8). The outcomes were designated as the 90-day modified Rankin Scale (mRS90) score (poor, 3-6). Student's t-test, chi-square test and logistic regression analyses were used to identify factors associated with a poor outcome. The median initial NIHSS score was 2 [interquartile range (IQR), 0-3], median posterior circulation Alberta Stroke Program Early CT Score was 8 (IQR, 7-10), median collateral score was 7 (IQR, 7-8) and 20 (20.4%) had poor mRS90 scores. In multivariate analysis, poorer collateral scores (P = 0.003), higher NIHSS scores (P = 0.005) and lower posterior circulation Alberta Stroke Program Early CT Score (P = 0.017) were independently associated with a poor mRS90 score. The DSA-based collateral scoring of the BA large branches might predict long-term outcome in medically treated symptomatic basilar artery stenosis with mild initial severity. Evaluation of BA collateral perfusion status might be useful to determine appropriate treatment strategies. © 2017 EAN.

  7. Detection of unruptured intracranial aneurysms on noninvasive imaging. Is there still a role for digital subtraction angiography?

    Science.gov (United States)

    Rustemi, Oriela; Alaraj, Ali; Shakur, Sophia F; Orning, Jennifer L; Du, Xinjian; Aletich, Victor A; Amin-Hanjani, Sepideh; Charbel, Fady T

    2015-01-01

    To determine the utility of digital subtraction angiography (DSA) in patients with unruptured intracranial aneurysms (UIA) detected on noninvasive imaging, such as magnetic resonance angiography (MRA) and computed tomography angiography (CTA). The follow-up of patients with untreated UIAs involves serial imaging; however, this diagnosis may be based on false positive (FP) results. We examined the incidence of FPs in our institutional series. DSAs performed at our institution from January 2011 to June 2014 were retrospectively reviewed and patients referred with UIA detected on noninvasive imaging were selected. Clinical presentation as well as aneurysm location, size, and number reported on DSA and noninvasive imaging were assessed. Two hundred and eighty six patients (mean age 56.8 years, female 74.8%) with a total of 355 UIA were included. Thirty-one patients had a symptomatic presentation. Analysis per patient showed the pooled FP rate of noninvasive imaging was 15%. MRA FP was 13% (22/171) and CTA FP was 18% (22/120). FP increased significantly with aneurysm size < 3.5 mm on MRA (P < 0.001) and <4.0 mm on CTA (P = 0.01). Mean aneurysm size among symptomatic patients was significantly larger (P < 0.001) as compared to the incidental group (17.8 vs. 7.7 mm). No location was significantly susceptible to false detection of aneurysms. DSA detection of FP UIA diagnosed on noninvasive imaging is significantly higher for aneurysms <4.0 mm. Accurate diagnosis with DSA may eliminate the need for further follow-up and its associated negative psychological and economic effects. Within the limitations of this retrospective study, we conclude that DSA has a diagnostic role in small aneurysms detected on noninvasive imaging.

  8. Three-dimensional CT-angiography after cerebral aneurysm clipping. Comparison with intra-arterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Sakuma, Ikuo; Tomura, Noriaki; Takahashi, Satoshi; Omachi, Koichi; Otani, Takahiro; Watarai, Jiro; Kinouchi, Hiroyuki; Mizoi, Kazuo

    2004-01-01

    To assess the significance of three-dimensional CT-angiography (3D-CTA) in detecting remnant necks after cerebral aneurysm clipping, 3D-CTA was compared with intra-arterial digital subtraction angiography (IADSA). Fifty-nine patients (79 aneurysms) underwent both IADSA and 3D-CTA after cerebral aneurysm clipping. A single detector spiral scanner was used for 3D-CTA. Shaded surface display (SSD) and volume rendered (VR) images were produced from each data set. Two blinded observers independently evaluated the presence of remnant necks on SSD images, VR images and IADSA. Results jointly evaluated by three observers were applied as the gold standard to assess diagnostic accuracy of each image. Diagnostic performance of each image was evaluated using receiver operating characteristic (ROC) analysis. Mean sensitivity and specificity of SSD images for detecting remnant necks were 50.0% and 74.2%, respectively. VR images displayed a mean sensitivity and specificity of 63.3% and 82.8%, respectively. IADSA demonstrated a mean sensitivity and specificity of 93.3% and 92.2%, respectively. Under ROC analysis, IADSA displayed excellent diagnostic performance (mean Az [area under ROC curve]=0.97). While 3D-CTA demonstrated good diagnostic performance (0.68 and 0.76 for SSD and VR, respectively), it was significantly inferior to IADSA (P<.001). Mean Az for VR imaging was significantly superior to that for SSD imaging (P<.001). Following clipping surgery for cerebral aneurysms, 3D-CTA, and particularly VR imaging, is useful for postoperative evaluation. As a noninvasive alternative, 3D-CTA could be recommended for routine use. However, IADSA should still be performed when 3D-CTA yields uncertain results. (author)

  9. A comparison of subtracted images from dental subtraction programs

    International Nuclear Information System (INIS)

    Han, Won Jeong

    2002-01-01

    To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p<0.01). Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  10. A comparison of subtracted images from dental subtraction programs

    Energy Technology Data Exchange (ETDEWEB)

    Han, Won Jeong [School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2002-09-15

    To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p<0.01). Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  11. Comparison of C-arm Computed Tomography and Digital Subtraction Angiography in Patients with Chronic Thromboembolic Pulmonary Hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Jan B., E-mail: hinrichs.jan@mh-hannover.de; Marquardt, Steffen, E-mail: marquardt.steffen@mh-hannover.de; Falck, Christian von, E-mail: falck.christian.von@mh-hannover.de [Hannover Medical School, Department for Diagnostic and Interventional Radiology, German Center for Lung Research (DZL) (Germany); Hoeper, Marius M., E-mail: hoeper.marius@mh-hannover.de; Olsson, Karen M., E-mail: olsson.karen@mh-hannover.de [Hannover Medical School, Clinic for Pneumology, German Center for Lung Research (DZL) (Germany); Wacker, Frank K., E-mail: wacker.frank@mh-hannover.de; Meyer, Bernhard C., E-mail: meyer.bernhard@mh-hannover.de [Hannover Medical School, Department for Diagnostic and Interventional Radiology, German Center for Lung Research (DZL) (Germany)

    2016-01-15

    PurposeTo assess the feasibility and diagnostic performance of contrast-enhanced, C-arm computed tomography (CACT) of the pulmonary arteries compared to digital subtraction angiography (DSA) in patients suffering from chronic thromboembolic pulmonary hypertension (CTEPH).MaterialsFifty-two patients with CTEPH underwent ECG-gated DSA and contrast-enhanced CACT. Two readers (R1, R2) independently evaluated pulmonary artery segments and their sub-segmental branching using DSA and CACT for optimal image quality. Afterwards, the diagnostic findings, i.e., intraluminal filling defects, stenosis, and occlusion, were compared. Inter-modality and inter-observer agreement was calculated, and subsequently consensus reading was done and correlated to a reference standard representing the overall consensus of both modalities. Fisher’s exact test and Cohen’s Kappa were applied.ResultsA total of 1352 pulmonary segments were evaluated, of which 1255 (92.8 %) on DSA and 1256 (92.9 %) on CACT were rated to be fully diagnostic. The main causes of the non-diagnostic image quality were motion artifacts on CACT (R1:37, R2:78) and insufficient contrast enhancement on DSA (R1:59, R2:38). Inter-observer agreement was good for DSA (κ = 0.74) and CACT (κ = 0.75), while inter-modality agreement was moderate (R1: κ = 0.46, R2: κ = 0.47). Compared to the reference standard, the inter-modality agreement for CACT was excellent (κ = 0.96), whereas it was inferior for DSA (κ = 0.61) due to the higher number of abnormal consensus findings read as normal on DSA.ConclusionCACT of the pulmonary arteries is feasible and provides additional information to DSA. CACT has the potential to improve the diagnostic work-up of patients with CTEPH and may be particularly useful prior to surgical or interventional treatment.

  12. Carbon dioxide digital subtraction angiography using a new gas management system; Digitale Subtraktionsangiographie mit Kohlendioxid unter Verwendung eines neuen Gasdosiersystems

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz-Rode, T.; Alzen, G.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum der RWTH Aachen (Germany)

    1997-07-01

    Purpose: The clinical evaluation of digital subtraction angiography with carbon dioxide using a newly developed low-tech CO{sub 2}-dosage- and injection system. Method and patients: The hand-held system (CO{sub 2} angio set) consists of a dosage chamber in connection with a special stopcock to apportion the gas. By optimising injection volume and pressure steady gas flow characteristics are approximated. A safety design prevents unintentional gas injection volume and pressure steady gas flow characteristics are approximated. A safety design prevents unintentional gas injection. CO{sub 2} arteriographies were performed on 185 patients. Main indications were renal insufficiency and a history of adverse reactions to iodinated contrast media. In patients with femoral connula access, catheterless reflux angiography was performed. Results: The injection system provided complete and coherent visualisation of the abdominal aorta, visceral, pelvic, and lower limb arteries via catheter (71 cases) or via femoral cannula using reflux technique (114 cases). Stenoses, occlusions, and collaterals were assessable. Employing the gas reflux over the aortic bifurcation bilateral run-off studies up to the calf trifurcation were performed via unilateral femoral cannula. Use of a dedicated stacking software improved image quality of distal femoral, popliteal and calf arteries. Conclusion: The CO{sub 2} management system allows adequate imaging of the arteries below the diaphragm. Ease and safety of use and low costs are advantageous. (orig.) [Deutsch] Ziel: Die klinische Erprobung der digitalen Subtraktionsangiographie mit Kohlendioxid unter Verwendung eines neuentwickelten, einfachen Gasdosier- und Injektionssystems. Methode und Patienten: Eine Dosierkammer mit einstellbarem Volumen in Verbindung mit einem Spezial-Hahn (CO{sub 2}-Angio-Set) portioniert das Gas. Durch Optimierung von Injektionsvolumen und -druck wurde eine konstante Ausstroemcharakteristik angenaehert. Das System wurde

  13. New method of digital angiography

    International Nuclear Information System (INIS)

    Hashiya, Junichi; Korenaga, Takeo; Sakurai, Kenji; Sakai, Fumikazu; Kato, Hisatoyo; Takano, Masao.

    1982-01-01

    New experience of digital angiography using Fuji Intelligent Diagnostic X-ray System was reported. The system utilizes newly developed high sensitivity imaging plate in conjunction with computerized image processor instead of image intensifier-TV series, thus drastically improving image quality. Initial clinical trial was made in 46 cases including intravenous digital subtraction angiography and transcatheter digital arteriography. The advantages of this method were summerized as: 1. better resolution, 2. wider field size, 3. more sophisticated image manipulation program. (author)

  14. Subtract it! fun with subtraction

    CERN Document Server

    First, Rachel

    2016-01-01

    Make math fun with Subtract It! Fun photographs, colorful graphics, and simple text are used to teach young readers basic math concepts. From Word Problems to Number Lines this book will help kids develop the math skills they need. A simple activity at the end of the book encourages kids to put subtraction to use! Aligned to Common Core standards and correlated to state standards. Sandcastle is an imprint of Abdo Publishing, a division of ABDO.

  15. A comparison between magnetic resonance angiography at 3 teslas (time-of-flight and contrast-enhanced) and flat-panel digital subtraction angiography in the assessment of embolized brain aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Nakiri, Guilherme S.; Santos, Antonio C.; Abud, Thiago G.; Abud, Daniel G., E-mail: gsnakiri@yahoo.com.b [University of Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Medical School. Div. of Radiology; Aragon, Davi C. [University of Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Medical School. Div. of Statistics; Colli, Benedicto O. [University of Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Medical School. Div. of Neurosurgery

    2011-07-01

    Purpose: to compare the time-of-flight and contrast-enhanced- magnetic resonance angiography techniques in a 3 Tesla magnetic resonance unit with digital subtraction angiography with the latest flat-panel technology and 3D reconstruction in the evaluation of embolized cerebral aneurysms. Introduction: many embolized aneurysms are subject to a recurrence of intra-aneurysmal filling. Traditionally, imaging surveillance of coiled aneurysms has consisted of repeated digital subtraction angiography. However, this method has a small but significant risk of neurological complications, and many authors have advocated the use of noninvasive imaging methods for the surveillance of embolized aneurysms. Methods: forty-three aneurysms in 30 patients were studied consecutively between November 2009 and May 2010. Two interventional neuro radiologists rated the time-of-flight-magnetic resonance angiography, the contrast enhanced-magnetic resonance angiography, and finally the digital subtraction angiography, first independently and then in consensus. The status of aneurysm occlusion was assessed according to the Raymond scale, which indicates the level of recanalization according to degrees: Class 1: excluded aneurysm; Class 2: persistence of a residual neck; Class 3: persistence of a residual aneurysm. The agreement among the analyses was assessed by applying the Kappa statistic. Results: inter-observer agreement was excellent for both methods (K = 0.93; 95 % CI: 0.84-1). Inter-technical agreement was almost perfect between time-of-flight-magnetic resonance angiography and digital subtraction angiography (K = 0.98; 95 % CI: 0.93-1) and between time-of-flight-magnetic resonance angiography and contrast enhanced-magnetic resonance angiography (K = 0.98; 95% CI: 0.93-1). Disagreement occurred in only one case (2.3%), which was classified as Class I by time-of-flight-magnetic resonance angiography and Class II by digital subtraction angiography. The agreement between contrast

  16. A comparison between magnetic resonance angiography at 3 teslas (time-of-flight and contrast-enhanced and flat-panel digital subtraction angiography in the assessment of embolized brain aneurysms

    Directory of Open Access Journals (Sweden)

    Guilherme S. Nakiri

    2011-01-01

    Full Text Available PURPOSE: To compare the time-of-flight and contrast-enhanced- magnetic resonance angiography techniques in a 3 Tesla magnetic resonance unit with digital subtraction angiography with the latest flat-panel technology and 3D reconstruction in the evaluation of embolized cerebral aneurysms. INTRODUCTION: Many embolized aneurysms are subject to a recurrence of intra-aneurismal filling. Traditionally, imaging surveillance of coiled aneurysms has consisted of repeated digital subtraction angiography. However, this method has a small but significant risk of neurological complications, and many authors have advocated the use of noninvasive imaging methods for the surveillance of embolized aneurysms. METHODS: Forty-three aneurysms in 30 patients were studied consecutively between November 2009 and May 2010. Two interventional neuroradiologists rated the time-of-flight-magnetic resonance angiography, the contrast-enhanced-magnetic resonance angiography, and finally the digital subtraction angiography, first independently and then in consensus. The status of aneurysm occlusion was assessed according to the Raymond scale, which indicates the level of recanalization according to degrees: Class 1: excluded aneurysm; Class 2: persistence of a residual neck; Class 3: persistence of a residual aneurysm. The agreement among the analyses was assessed by applying the Kappa statistic. RESULTS: Inter-observer agreement was excellent for both methods (K = 0.93; 95 % CI: 0.84-1. Inter-technical agreement was almost perfect between time-of-flight-magnetic resonance angiography and digital subtraction angiography (K = 0.98; 95 % CI: 0.93-1 and between time-of-flight-magnetic resonance angiography and contrast-enhanced-magnetic resonance angiography (K = 0.98; 95% CI: 0.93-1. Disagreement occurred in only one case (2.3%, which was classified as Class I by time-of-flight-magnetic resonance angiography and Class II by digital subtraction angiography. The agreement between

  17. Utility of time-resolved three-dimensional magnetic resonance digital subtraction angiography without contrast material for assessment of intracranial dural arterio-venous fistula

    International Nuclear Information System (INIS)

    Hori, Masaaki; Aoki, Shigeki; Nakanishi, Atsushi; Shimoji, Keigo; Kamagata, Koji; Houshito, Haruyoshi; Kuwatsuru, Ryohei; Oishi, Hidenori; Arai, Hajime

    2011-01-01

    Background: Intracranial dural arteriovenous fistula (DAVF) is an arteriovenous shunting disease of the dura. Magnetic resonance angiography (MRA) is expected to be a safer alternative method in evaluation of DAVF, compared with invasive intra-arterial digital subtraction angiography (IADSA). Purpose: To evaluate the diagnostic use of time-spatial labeling inversion pulse (Time-SLIP) three-dimensional (3D) magnetic resonance digital subtraction angiography (MRDSA) without contrast material in six patients with DAVF. Material and Methods: Images for 3D time-of-flight MRA, which has been a valuable tool for the diagnosis of DAVF but provide little or less hemodynamic information, and Time-SLIP 3D MRDSA, were acquired for each patient. The presence, side, and grade of the disease were evaluated according to IADSA. Results: In all patients, the presence and side of the DAVF were correctly identified by both 3D time-of-flight MRA and Time-SLIP 3D MRDSA. Cortical reflux present in a patient with a grade 2b DAVF was not detected by Time-SLIP 3D MRDSA, when compared with IADSA findings. Conclusion: Time-SLIP 3D MRDSA provides hemodynamic information without contrast material and is a useful complementary tool for diagnosis of DAVF

  18. Quantitative analysis of errors in alveolar crest level caused by discrepant projection geometry in digital subtraction radiography: an in vivo study.

    Science.gov (United States)

    Huh, Kyung-Hoe; Lee, Sam-Sun; Jeon, In-Seong; Yi, Won-Jin; Heo, Min-Suk; Choi, Soon-Chul

    2005-12-01

    This study compared the difference between 3 intraoral radiographic techniques on digital subtraction radiography (DSR) in vivo that are commonly used in a clinical setting. We evaluated and statistically analyzed the errors in the DSR image in 6 regions with 3 radiographic techniques: paralleling technique with a bite block attached to XCP, paralleling technique using XCP, and bisecting-angle technique. The amount of error using the bisecting-angle technique was too large for DSR, compared to that of the paralleling technique with a bite block attached to XCP. In the mandibular anterior region, the paralleling technique using XCP was not different from paralleling technique with a bite block attached to XCP. The lowest degree of error was present in the anterior region whereas the highest was present in the molar region. Bisecting-angle technique should be avoided, and paralleling technique using XCP can be used in the mandibular anterior region for DSR.

  19. Tests of variable-band multilayers designed for investigating optimal signal-to-noise vs artifact signal ratios in Dual-Energy Digital Subtraction Angiography (DDSA) imaging systems

    International Nuclear Information System (INIS)

    Boyers, D.; Ho, A.; Li, Q.; Piestrup, M.; Rice, M.; Tatchyn, R.

    1993-08-01

    In recent work, various design techniques were applied to investigate the feasibility of controlling the bandwidth and bandshape profiles of tungsten/boron-carbon (W/B 4 C) and tungsten/silicon (W/Si) multilayers for optimizing their performance in synchrotron radiation based angiographical imaging systems at 33 keV. Varied parameters included alternative spacing geometries, material thickness ratios, and numbers of layer pairs. Planar optics with nominal design reflectivities of 30%--94% and bandwidths ranging from 0.6%--10% were designed at the Stanford Radiation Laboratory, fabricated by the Ovonic Synthetic Materials Company, and characterized on Beam Line 4-3 at the Stanford Synchrotron Radiation Laboratory, in this paper we report selected results of these tests and review the possible use of the multilayers for determining optimal signal to noise vs. artifact signal ratios in practical Dual-Energy Digital Subtraction Angiography systems

  20. Clinically useful dilution factors for iodine and gadolinium contrast material: an animal model of pediatric digital subtraction angiography using state-of-the-art flat-panel detectors.

    Science.gov (United States)

    Racadio, John M; Kashinkunti, Soumya R; Nachabe, Rami A; Racadio, Judy M; Johnson, Neil D; Kukreja, Kamlesh U; Patel, Manish N; Privitera, Mary Beth; Hales, Jasmine E; Abruzzo, Todd A

    2013-11-01

    Iodinated and gadolinium contrast agents pose some risk for certain pediatric patients, including allergic-like reactions, contrast-induced nephropathy (CIN) and nephrogenic systemic fibrosis (NSF). Digital flat-panel detectors enhance image quality during angiography and might allow use of more dilute contrast material to decrease risk of complications that might be dose-dependent, such as CIN and NSF. To assess the maximum dilution factors for iodine- and gadolinium-based contrast agents suitable for vascular imaging with fluoroscopy and digital subtraction angiography (DSA) on digital flat-panel detectors in an animal model. We performed selective catheterization of the abdominal aorta, renal artery and common carotid artery on a rabbit. In each vessel we performed fluoroscopy and DSA during contrast material injection using iodinated and gadolinium contrast material at 100%, 80%, 50%, 33% and 20% dilutions. An image quality score (0 to 3) was assigned by each of eight evaluators. Intracorrelation coefficient, paired t-test, one-way repeated analysis of variance, Spearman correlation and receiver operating characteristic curve analysis were applied to the data. Overall the image quality scores correlated linearly with dilution levels. For iodinated contrast material, the optimum cut-off level for DSA when a score of at least 2 is acceptable is above 33%; it is above 50% when a score of 3 is necessary. For gadolinium contrast material, the optimum cut-off for DSA images is above 50% when a score of at least 2 is acceptable and above 80% when a score of 3 is necessary. Knowledge of the relationship between image quality and contrast material dilution might allow a decrease in overall contrast load while maintaining appropriate image quality when using digital flat-panel detectors.

  1. Contexts for Column Addition and Subtraction

    Science.gov (United States)

    Lopez Fernandez, Jorge M.; Velazquez Estrella, Aileen

    2011-01-01

    In this article, the authors discuss their approach to column addition and subtraction algorithms. Adapting an original idea of Paul Cobb and Erna Yackel's from "A Contextual Investigation of Three-Digit Addition and Subtraction" related to packing and unpacking candy in a candy factory, the authors provided an analogous context by…

  2. Four-dimensional CT angiography (4D-CTA) in the evaluation of juvenile nasopharyngeal angiofibromas: comparison with digital subtraction angiography (DSA) and surgical findings.

    Science.gov (United States)

    Xiao, Zebin; Zheng, Yingyan; Li, Jian; Chen, Dehua; Liu, Fang; Cao, Dairong

    2017-12-01

    To explore the value of four-dimensional CT angiography (4D-CTA) in the preoperative evaluation of juvenile nasopharyngeal angiofibromas (JNAs) using 320-row volume CT. 4D-CTA and DSA data of 18 patients with histopathologically proven JNAs were retrospectively reviewed. The location, extent, feeding vessels and stage of JNAs were assessed by two radiologists independently and blindly. The agreements between both reviewers and between 4D-CTA and surgical findings for assessing the above indicators were analysed, respectively. The radiation dose and the number of feeding arteries between 4D-CTA and digital subtraction angiography (DSA) were also compared. 4D-CTA showed high diagnostic consistency with surgical pathology for JNAs with consistent rates of 96.2 and 100% in both reviewers, respectively. The effective dose of 4D-CTA was significantly less than that of DSA (p 0.05). 4D-CTA can provide a reliable preoperative diagnosis and assessment of JNAs, which is useful for determining the surgical strategy and management of this condition.

  3. Dual-energy CT head bone and hard plaque removal for quantification of calcified carotid stenosis: utility and comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Uotani, Kensuke; Watanabe, Yoshiyuki; Higashi, Masahiro; Nakazawa, Tetsuro; Kono, Atsushi K.; Hori, Yoshiro; Fukuda, Tetsuya; Kanzaki, Suzu; Yamada, Naoaki; Naito, Hiroaki; Itoh, Toshihide; Sugimura, Kazuro

    2009-01-01

    We evaluated quantification of calcified carotid stenosis by dual-energy (DE) CTA and dual-energy head bone and hard plaque removal (DE hard plaque removal) and compared the results to those of digital subtraction angiography (DSA). Eighteen vessels (13 patients) with densely calcified carotid stenosis were examined by dual-source CT in the dual-energy mode (tube voltages 140 kV and 80 kV). Head bone and hard plaques were removed from the dual-energy images by using commercial software. Carotid stenosis was quantified according to NASCET criteria on MIP images and DSA images at the same plane. Correlation between DE CTA and DSA was determined by cross tabulation. Accuracies for stenosis detection and grading were calculated. Stenosis could be evaluated in all vessels by DE CTA after applying DE hard plaque removal. In contrast, conventional CTA failed to show stenosis in 13 out of 18 vessels due to overlapping hard plaque. Good correlation between DE plaque removal images and DSA images was observed (r 2 =0.9504) for stenosis grading. Sensitivity and specificity to detect hemodynamically relevant (>70%) stenosis was 100% and 92%, respectively. Dual-energy head bone and hard plaque removal is a promising tool for the evaluation of densely calcified carotid stenosis. (orig.)

  4. Comparison of high-resolution contrast-enhanced 3D MRA with digital subtraction angiography in the evaluation of hepatic arterial anatomy

    International Nuclear Information System (INIS)

    Matoba, M.; Tonami, H.; Kuginuki, M.; Yokota, H.; Takashima, S.; Yamamoto, I.

    2003-01-01

    AIM: To evaluate the validity of high-resolution contrast-enhanced three-dimensional magnetic resonance angiography (MRA) in defining hepatic arterial anatomy and to compare this with digital subtraction angiography (DSA). MATERIALS AND METHODS: MRA and DSA were performed in 30 patients. MRA was performed with breath-hold, gadolinium-enhanced, three-dimensional, fast low-angle shot sequence with a 512 pixel matrix. MRA was compared with DSA in terms of image quality and depiction of hepatic arterial anatomy. The agreement in image quality between MRA and DSA was determined with the kappa statistic. RESULTS: With respect to image quality, there was excellent or good correlation between MRA and DSA for the common hepatic artery (κ=0.85), proper hepatic artery (κ=0.72), gastroduodenal artery (κ=0.70), left hepatic artery (κ=0.49), left gastric artery (κ=0.50), splenic artery (κ=0.84), and superior mesenteric artery (κ=0.88). Poor correlation was found for the right hepatic artery (κ=0.18) and right gastric artery (κ=0.38). With regard to hepatic arterial anatomy, MRA correlated correctly with DSA in 28 of the 29 cases, i.e. 97% of patients. CONCLUSION: MRA is a useful technique for the evaluation of the hepatic artery, and for the vast majority of patients, MRA can replace intra-arterial DSA

  5. Detection and characterization of intracranial aneurysms with 16-channel multidetector row CT angiography: a prospective comparison of volume-rendered images and digital subtraction angiography.

    Science.gov (United States)

    Yoon, D Y; Lim, K J; Choi, C S; Cho, B M; Oh, S M; Chang, S K

    2007-01-01

    The aim of our study was to compare multidetector row CT angiography (MDCTA) with digital subtraction angiography (DSA) in the detection and characterization of intracranial aneurysms. In our blinded prospective study, 85 patients with suspected intracranial aneurysm (47 women, 38 men; age range, 19-83 years) underwent both 16-channel MDCTA and DSA. The MDCT angiograms were interpreted for the presence, location, size, ratio of the neck to the dome (N/D ratio), and lobularity of the aneurysms and relationship of the aneurysm with the adjacent arterial branches, by using volume-rendering techniques. MDCTA and DSA images (reference standard) were interpreted by 2 independent readers, and the results were compared. A total of 93 aneurysms were detected at DSA in 71 patients, whereas no aneurysms were detected in 14 patients. Compared with DSA, the overall sensitivity, specificity, and accuracy of MDCTA on a per-aneurysm basis were 92.5%, 93.3%, and 92.6%, respectively, for both independent readers. For aneurysms of <3 mm, however, MDCTA had a sensitivity of 74.1% for reader 1 and 77.8% for reader 2. There was excellent agreement between readers in the detection of aneurysms (kappa = 0.822). In addition, MDCTA was also accurate in determining N/D ratio of aneurysms, aneurysm lobularity, and adjacent arterial branches. MDCTA is accurate in the detection and characterization of intracranial aneurysms and can be used as a reliable alternative imaging technique to DSA in selected cases.

  6. The value of magnetic resonance imaging for the detection of the bleeding source in non-traumatic intracerebral haemorrhages: a comparison with conventional digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lummel, Nina; Lutz, Juergen; Brueckmann, Hartmut; Linn, Jennifer [University of Munich, Department of Neuroradiology, Munich (Germany)

    2012-07-15

    Conventional digital subtraction angiography (DSA) is currently regarded as the gold standard in detecting underlying vascular pathologies in patients with intracerebral haemorrhages (ICH). However, the use of magnetic resonance imaging (MRI) in the diagnostic workup of ICHs has considerably increased in recent years. Our aim was to evaluate the diagnostic accuracy and yield of MRI for the detection of the underlying aetiology in ICH patients. Sixty-seven consecutive patients with an acute ICH who underwent MRI (including magnetic resonance angiography (MRA) and DSA during their diagnostic workup) were included in the study. Magnetic resonance images were retrospectively analysed by two independent neuroradiologists to determine the localisation and cause of the ICH. DSA was used as a reference standard. In seven patients (10.4%), a DSA-positive vascular aetiology was present (one aneurysm, four arteriovenous malformations, one dural arteriovenous fistula and one vasculitis). All of these cases were correctly diagnosed by both readers on MRI. In addition, MRI revealed the following probable bleeding causes in 39 of the 60 DSA-negative patients: cerebral amyloid angiopathy (17), cavernoma (9), arterial hypertension (8), haemorrhagic transformation of an ischaemic infarction (3) and malignant brain tumour with secondary ICH (2). Performing MRI with MRA proved to be an accurate diagnostic tool in detecting vascular malformations in patients with ICH. In addition, MRI provided valuable information regarding DSA-negative ICH causes, and thus had a high diagnostic yield in ICH patients. (orig.)

  7. Conventional digital subtraction x-ray angiography versus magnetic resonance angiography in the evaluation of carotid disease: patient satisfaction and preferences

    Energy Technology Data Exchange (ETDEWEB)

    U-King-Im, J.M. E-mail: jhg21@cam.ac.uk; Trivedi, R.; Cross, J.; Higgins, N.; Graves, M.; Kirkpatrick, P.; Antoun, N.; Gillard, J.H

    2004-04-01

    AIM: To compare conventional digital subtraction x-ray angiography (DSA) and contrast-enhanced magnetic resonance angiography (MRA) of the carotid arteries in terms of patient satisfaction and preferences. METHODS: One hundred and sixty-seven patients with symptomatic carotid artery disease, who underwent both DSA and MRA, were prospectively recruited in this study. Patients' perceptions of each method were assessed by the use of a questionnaire after each procedure. Main outcome measures were anxiety, pain, satisfaction rate and patient preferences. RESULTS: DSA generated more anxiety and pain during the procedure, but the severity of these ill-effects was mild. Satisfaction rates for each method were similar. More patients were, however, willing to have a repeat MRA compared with DSA (67 versus 41%). The majority of patients (62%) preferred MRA over DSA (31%). The shorter MRA imaging time was found to be a significant factor in patients' acceptance of the technique. The main reasons cited by patients for their dislike of a particular procedure was noise and claustrophobia for MRA and invasiveness, pain and post-procedural bed rest for DSA. CONCLUSIONS: MRA is the method that is preferred by the majority of patients, although the actual disutility of DSA may be small. Assuming equal diagnostic accuracy, our data supports replacement of DSA by MRA for routine carotid imaging.

  8. Gadobutrol-enhanced moving-table magnetic resonance angiography in patients with peripheral vascular disease: a prospective, multi-centre blinded comparison with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Hentsch, Annette [Schering AG, Berlin (Germany); Aschauer, Manuela A.; Ebner, Franz [Department of Magnetic Resonance, University of Graz, Graz (Austria); Balzer, Joern O.; Davis, Kirsten [Department of Diagnostic and Interventional Radiology, University of Frankfurt/Main, Frankfurt/Main (Germany); Brossmann, Joachim; Schaefer, Fritz K.W. [Department of Diagnostic Radiology, University of Kiel, Kiel (Germany); Busch, Hans P. [Krankenhaus der Barmherzigen Brueder, Trier (Germany); Douek, Philippe [Department of Diagnostic Radiology, University of Lyon (France); Engelshoven, Jos M.A. van; Leiner, Tim [Department of Radiology, Cardiovascular Research Institute, University of Maastricht, Maastricht (Netherlands); Gregor, Michaela; Reimer, Peter [Department of Radiology, Staedtisches Klinikum, Karlsruhe (Germany); Kersting, Christian [Department of Diagnostic Radiology, University of Muenster, Muenster (Germany); Knuesel, Patrick R. [Institute of Diagnostic Radiology, University Hospital Zurich, MRI Center, Zurich (Switzerland); Leen, Edward [Department of X-ray, Glasgow Royal Infirmary, Glasgow (United Kingdom); Loewe, Christian; Thurnher, Siegfried A. [Section of Angiography and Interventional Radiology, Department of Radiology' ' University of Vienna, Vienna (Austria); McPherson, Simon [Department of Radiology, University of Leeds, Leeds (United Kingdom); Taupitz, Matthias [Department of Radiology, Humboldt University of Berlin (Charite), Berlin (Germany); Tombach, Bernd; Wegener, Robin; Weishaupt, Dominik; Meaney, James F.M.

    2003-09-01

    The purpose of this study was to compare moving-table three-dimensional contrast-enhanced magnetic resonance angiography (CE MRA), using 1.0-mol gadobutrol, with intra-arterial digital subtraction angiography (i.a. DSA) for evaluation of pelvic and peripheral arteries in patients with peripheral arterial occlusive disease. A total of 203 patients were examined in a prospective, multi-centre study at 1.0/1.5 T. Ten vessel segments of one leg were evaluated on-site and by three independent blinded reviewers off-site. One hundred eighty-two patients were evaluable in blinded reading. For pelvis and thigh, there was statistically significant diagnostic agreement between CE MRA and i.a. DSA on-site (94%) and off-site (86-88%). Overall, for detection of clinically significant stenoses, 93% sensitivity and 90% specificity were achieved in on-site evaluation, with 71-76 and 87-93% off-site; for detection of occlusion, sensitivity and specificity on-site were 91 and 97%, with 75-82 and 94-98% off-site. Evaluation was more sensitive on-site than off-site for detection of stenoses and occlusion, whereas specificity was similar. The CE MRA with 1.0-mol gadobutrol gave results comparable to those of i.a. DSA for the larger arteries of pelvis and thigh. Results for calf arteries were compromised by spatial resolution and technical limitations. (orig.)

  9. TU-CD-207-03: Time Evolution of Texture Parameters of Subtracted Images Obtained by Contrast-Enhanced Digital Mammography (CEDM)

    Energy Technology Data Exchange (ETDEWEB)

    Mateos, M-J; Brandan, M-E [Instituto de Fisica, Universidad Nacional Autonom de Mexico, Mexico, Distrito Federal (Mexico); Gastelum, A; Marquez, J [Centro de Ciencias Aplicadas y Desarrollo Tecnologico Universidad Nacional Autonoma de Mexico, Mexico, Distrito Federal (Mexico)

    2015-06-15

    Purpose: To evaluate the time evolution of texture parameters, based on the gray level co-occurrence matrix (GLCM), in subtracted images of 17 patients (10 malignant and 7 benign) subjected to contrast-enhanced digital mammography (CEDM). The goal is to determine the sensitivity of texture to iodine uptake at the lesion, and its correlation (or lack of) with mean-pixel-value (MPV). Methods: Acquisition of clinical images followed a single-energy CEDM protocol using Rh/Rh/48 kV plus external 0.5 cm Al from a Senographe DS unit. Prior to the iodine-based contrast medium (CM) administration a mask image was acquired; four CM images were obtained 1, 2, 3, and 5 minutes after CM injection. Temporal series were obtained by logarithmic subtraction of registered CM minus mask images.Regions of interest (ROI) for the lesion were drawn by a radiologist and the texture was analyzed. GLCM was evaluated at a 3 pixel distance, 0° angle, and 64 gray-levels. Pixels identified as registration errors were excluded from the computation. 17 texture parameters were chosen, classified according to similarity into 7 groups, and analyzed. Results: In all cases the texture parameters within a group have similar dynamic behavior. Two texture groups (associated to cluster and sum mean) show a strong correlation with MPV; their average correlation coefficient (ACC) is r{sup 2}=0.90. Other two groups (contrast, homogeneity) remain constant with time, that is, a low-sensitivity to CM uptake. Three groups (regularity, lacunarity and diagonal moment) are sensitive to CM uptake but less correlated with MPV; their ACC is r{sup 2}=0.78. Conclusion: This analysis has shown that, at least groups associated to regularity, lacunarity and diagonal moment offer dynamical information additional to the mean pixel value due to the presence of CM at the lesion. The next step will be the analysis in terms of the lesion pathology. Authors thank PAPIIT-IN105813 for support. Consejo Nacional de Ciencia Y

  10. Quantitative Real-Time Fluoroscopy Analysis on Measurement of the Hepatic Arterial Flow During Transcatheter Arterial Chemoembolization of Hepatocellular Carcinoma: Comparison with Quantitative Digital Subtraction Angiography Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yi-Yang; Lee, Rheun-Chuan, E-mail: rclee@vghtpe.gov.tw; Guo, Wan-Yuo, E-mail: wyguo@vghtpe.gov.tw; Chu, Wei-Fa [Taipei Veterans General Hospital, Department of Radiology (China); Wu, Frank Chun-Hsien [Siemens Healthcare Ltd. (China); Gehrisch, Sonja [Siemens Healthcare GmbH (Germany)

    2016-11-15

    PurposeTo quantify the arterial flow change during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) using digital subtraction angiography, quantitative color-coding analysis (d-QCA), and real-time subtraction fluoroscopy QCA (f-QCA).Materials and MethodsThis prospective study enrolled 20 consecutive patients with HCC who had undergone TACE via a subsegmental approach between February 2014 and April 2015. The TACE endpoint was a sluggish antegrade tumor-feeding arterial flow. d-QCA and f-QCA were used for determining the relative maximal density time (rT{sub max}) of the selected arteries. The rT{sub max} of the selected arteries was analyzed in d-QCA and f-QCA before and after TACE, and its correlation in both analyses was evaluated.ResultsThe pre- and post-TACE rT{sub max} of the embolized segmental artery in d-QCA and f-QCA were 1.59 ± 0.81 and 2.97 ± 1.80 s (P < 0.001) and 1.44 ± 0.52 and 2.28 ± 1.02 s (P < 0.01), respectively. The rT{sub max} of the proximal hepatic artery did not significantly change during TACE in d-QCA and f-QCA. The Spearman correlation coefficients of the pre- and post-TACE rT{sub max} of the embolized segmental artery between d-QCA and f-QCA were 0.46 (P < 0.05) and 0.80 (P < 0.001). Radiation doses in one series of d-QCA and f-QCA were 140.7 ± 51.5 milligray (mGy) and 2.5 ± 0.7 mGy, respectively.Conclusionsf-QCA can quantify arterial flow changes with a higher temporal resolution and lower radiation dose. Flow quantification of the embolized segmental artery using f-QCA and d-QCA is highly correlated.

  11. Time-of-flight MR angiography at 3 T versus digital subtraction angiography in the imaging follow-up of 51 intracranial aneurysms treated with coils

    Energy Technology Data Exchange (ETDEWEB)

    Ferre, Jean-Christophe [Department of Neuroradiology, Hopital Pontchaillou, University Hospital Rennes, 2 rue Henri Le Guilloux, 35000 Rennes (France)], E-mail: jean-christophe.ferre@chu-rennes.fr; Carsin-Nicol, Beatrice [Department of Neuroradiology, Hopital Pontchaillou, University Hospital Rennes, 2 rue Henri Le Guilloux, 35000 Rennes (France); Morandi, Xavier [Department of Neurosurgery, Hopital Pontchaillou, University Hospital Rennes, 2 rue Henri Le Guilloux, 35000 Rennes (France); Carsin, Michel [Department of Neuroradiology, Hopital Pontchaillou, University Hospital Rennes, 2 rue Henri Le Guilloux, 35000 Rennes (France); Kersaint-Gilly, Axel de [Department of Neuroradiology, Hopital Laennec, University Hospital Nantes, Boulevard Jacques Monod, 44800 Saint-Herblain (France); Gauvrit, Jean-Yves [Department of Neuroradiology, Hopital Pontchaillou, University Hospital Rennes, 2 rue Henri Le Guilloux, 35000 Rennes (France); Desal, Hubert-Armand [Department of Neuroradiology, Hopital Laennec, University Hospital Nantes, Boulevard Jacques Monod, 44800 Saint-Herblain (France)

    2009-12-15

    Objective: To compare 3D time-of-flight MR angiography (TOF-MRA) at 3 Tesla (3 T) with digital subtraction angiography (DSA) for the evaluation of intracranial aneurysm occlusion after endovascular coiling. Methods: In a prospective study, 51 consecutive patients (25 females, 26 males; median age, 51 years) with 51 saccular aneurysms treated with endovascular coiling underwent simultaneous DSA and 3 T TOF-MRA at follow-up. DSA and TOF-MRA images were analyzed independently by two senior neuroradiologists. Findings were assigned to 1 of 3 categories in the Raymond classification: complete obliteration, residual neck or residual aneurysm. Agreement between observers and techniques was evaluated using {kappa} statistics. Results: DSA images were not interpretable for one patient. Interobserver agreement was determined as excellent for DSA ({kappa} = 0.86) and TOF-MRA ({kappa} = 0.80). After reaching a consensus, DSA follow-up showed 26 (51%) complete obliterations, 20 (39%) residual necks and 4 (8%) residual aneurysms. TOF-MRA showed 23 (45%) complete obliterations, 22 (43%) residual necks and 6 (12%) residual aneurysms. Comparison between TOF-MRA and DSA showed excellent agreement between the techniques ({kappa} = 0.86). In the four cases that were misclassified, TOF-MRA findings were assigned to a higher class than for DSA. Conclusion: TOF-MRA at 3 T is at least as efficient as DSA for the evaluation of intracranial aneurysm occlusion after endovascular treatment with detachable coils. We suggest that TOF-MRA at 3 T might be used as the primary method for imaging follow-up of coiled intracranial aneurysms.

  12. Value of Single-Dose Contrast-Enhanced Magnetic Resonance Angiography Versus Intraarterial Digital Subtraction Angiography in Therapy Indications in Abdominal and Iliac Arteries

    International Nuclear Information System (INIS)

    Schaefer, Philipp J.; Schaefer, Fritz K. W.; Mueller-Huelsbeck, Stefan; Both, Markus; Heller, Martin; Jahnke, Thomas

    2007-01-01

    The objective of the study was to prove the value of single-dose contrast-enhanced magnetic resonance angiography [three-dimensional (3D) ceMRA] in abdominal and iliac arteries versus the reference standard intra-arterial digital subtraction angiography (i.a.DSA) when indicating a therapy. Patients suspected of having abdominal or iliac artery stenosis were included in this study. A positive vote of the local Ethics Committee was given. After written informed consent was obtained, 37 patients were enrolled, of which 34 were available for image evaluation. Both 3D ceMRA and i.a. DSA were performed for each patient. The dosage for 3D ceMRA was 0.1 mmol/kg body weight in a 1.5-T scanner with a phased-array coil. The parameters of the 3D-FLASH sequence were as follows: TR/TE 4.6/1.8 ms, effective thickness 3.5 mm, matrix 512 x 200, flip angle 30 o , field of view 420 mm, TA 23 s, coronal scan orientation. Totally, 476 vessel segments were evaluated for stenosis degree by two radiologists in a consensus fashion in a blinded read. For each patient, a therapy was proposed, if clinically indicated. Sensitivity, specificity, positive and negative predictive values, and accuracy for stenoses ≥50% were 68%, 92%, 44%, 97%, and 90%, respectively. In 13/34 patients, a discrepancy was found concerning therapy decisions based on MRA findings versus therapy decisions based on the reference standard DSA. The results showed that the used MRA imaging technique of abdominal and iliac arteries is not competitive to i.a. DSA, with a high rate of misinterpretation of the MRAs resulting in incorrect therapies

  13. Quantitative perfusion computed tomography measurements of cerebral hemodynamics: Correlation with digital subtraction angiography identified primary and secondary cerebral collaterals in internal carotid artery occlusive disease

    International Nuclear Information System (INIS)

    Cheng Xiaoqing; Tian Jianming; Zuo Changjing; Liu Jia; Zhang Qi; Lu Guangming

    2012-01-01

    Background: The aim of the present study was to assess hemodynamic variations in symptomatic unilateral internal carotid artery occlusion (ICAO) patients with primary collateral flow via circle of Willis or secondary collateral flow via ophthalmic artery and/or leptomeningeal collaterals. Methods: Thirty-eight patients with a symptomatic unilateral ICAO were enrolled in the study. Based on digital subtraction angiography (DSA) findings, patients were classified into 2 groups: primary collateral (n = 14) and secondary collateral (n = 24) groups. Collateral flow hemodynamics were investigated with perfusion computed tomography (PCT) by measuring the cerebral blood flow (CBF), cerebral blood volume (CBV) and time to peak (TTP) in the hemispheres ipsilateral and contralateral to ICAO. Based on the measurements, the ipsilateral to contralateral ratio for each parameter was calculated and compared. Results: Irrespective of the collateral patterns, ipsilateral CBF was not significantly different from that of the contralateral hemisphere (P = 0.285); ipsilateral CBV and TTP was significantly increased compared with those of the contralateral hemisphere (P = 0.000 and P = 0.000 for CBV and TTP, respectively). Furthermore, patients with secondary collaterals had significantly larger ipsilateral-to-contralateral ratios for both CBV (rCBV, P = 0.0197) and TTP (rTTP, P = 0.000) than those of patients with only primary collaterals. These two groups showed no difference in ipsilateral-to-contralateral ratio for CBF (rCBF, P = 0.312). Conclusion: Patients with symptomatic unilateral ICAO in our study were in an autoregulatory vasodilatation status. Moreover, secondary collaterals in ICAO patients were correlated with ipsilateral CBV and delayed TTP that suggested severe hemodynamic impairment, presumably increasing the risk of ischemic events.

  14. Digital fluorography and computed tomography in a department of neuroradiology - a comparative study

    International Nuclear Information System (INIS)

    Fawcitt, R.A.; Freer, C.; Jarvis, H.; Occleshaw, J.V.; Isherwood, I.

    1984-01-01

    Digital Subtraction Angiography (DSA) has the ability to display the intracranial circulation following an intravenous or intra-arterial injection of contrast medium. A study was performed in 57 patients with neurological disorders undergoing DSA, either by Digital Intravenous Injection Angiography (DIVA) or Digital Intra-arterial Injection Angiography (DART) to assess the ability of DIVA to replace DART, the latter being carried out by digital fluorography or by conventional film screen methods, and also to establish the role of DSA in relation to Computed Tomography. (U.K.)

  15. TU-H-CAMPUS-IeP1-04: Combined Organ Dose for Digital Subtraction Angiography and Computed Tomography Using Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Sakabe, D; Ohno, T; Araki, F; Hashida, M; Funama, Y [Kumamota University, Kumamoto, Kumamoto (Japan)

    2016-06-15

    Purpose: The purpose of this study was to evaluate the combined organ dose of digital subtraction angiography (DSA) and computed tomography (CT) using a Monte Carlo (MC) simulation on the abdominal intervention. Methods: The organ doses for DSA and CT were obtained with MC simulation and actual measurements using fluorescent-glass dosimeters at 7 abdominal portions in an Alderson-Rando phantom. DSA was performed from three directions: posterior anterior (PA), right anterior oblique (RAO), and left anterior oblique (LAO). The organ dose with MC simulation was compared with actual radiation dose measurements. Calculations for the MC simulation were carried out with the GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. Finally, the combined organ dose for DSA and CT was calculated from the MC simulation using the X-ray conditions of a patient with a diagnosis of hepatocellular carcinoma. Results: For DSA from the PA direction, the organ doses for the actual measurements and MC simulation were 2.2 and 2.4 mGy/100 mAs at the liver, respectively, and 3.0 and 3.1 mGy/100 mAs at the spinal cord, while for CT, the organ doses were 15.2 and 15.1 mGy/100 mAs at the liver, and 14.6 and 13.5 mGy/100 mAs at the spinal cord. The maximum difference in organ dose between the actual measurements and the MC simulation was 11.0% of the spleen at PA, 8.2% of the spinal cord at RAO, and 6.1% of left kidney at LAO with DSA and 9.3% of the stomach with CT. The combined organ dose (4 DSAs and 6 CT scans) with the use of actual patient conditions was found to be 197.4 mGy for the liver and 205.1 mGy for the spinal cord. Conclusion: Our method makes it possible to accurately assess the organ dose to patients for abdominal intervention with combined DSA and CT.

  16. Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Juan; Sun, Gang; Yu, Bling Bing; Li, Min; Li, Guo Ying; Peng, Zhao Hui; Zhang, Xu Ping [Dept. of Medical Imaging, Jinan Military General Hospital, Jinan (China); Lu, Yang [Dept. of Radiology, University of Illinois College of Medicine, Illinois (United States)

    2012-11-15

    To explore the usefulness of 320-slice CT angiography (CTA) for evaluating the course of the anterior ethmoidal artery (AEA) and its relationship with adjacent structures by using three-dimensional (3D) spin digital subtraction angiography (DSA) as standard reference. From December 2008 to December 2010, 32 patients with cerebrovascular disease, who underwent both cranial 3D spin DSA and 320-slice CTA within a 30 day period from each other, were retrospectively reviewed. AEA course in ethmoid was analyzed in DSA and CTA. In addition, adjacent bony landmarks (bony notch in medial orbital wall, anterior ethmoidal canal, and anterior ethmoidal sulcus) were evaluated with CTA using the MPR technique oriented along the axial, coronal and oblique coronal planes in all patients. The dose length product (DLP) for CTA and the dose-area product (DAP) for 3D spin DSA were recorded. Effective dose (ED) was calculated. The entire course of the AEA was seen in all 32 cases (100%) with 3D spine DSA and in 29 of 32 cases (90.1%) with 320-slice CTA, with no significant difference (p = 0.24). In three cases where AEA was not visualized on 320-slice CTA, two were due to the dominant posterior ethmoidal artery, while the remaining case was due to diminutive AEA. On MPR images of 320-slice CT, a bony notch in the orbital medial walls was detected in all cases (100%, 64 of 64); anterior ethmoidal canal was seen in 28 of 64 cases (43.8%), and the anterior ethmoidal sulcus was seen in 63 of 64 cases (98.4%). The mean effective dose in CTA was 0.6 {+-} 0.25 mSv, which was significantly lower than for 3D spin DSA (1.3 {+-} 0.01 mSv) (p < 0.001). 320-slice CTA has a similar detection rate for AEA to that of 3D spin DSA; however, it is noninvasive, and may be preferentially used for the evaluation of AEA and its adjacent bony variations and pathologic changes in preoperative patients with paranasal sinus diseases.

  17. Impact of femoral artery puncture using digital subtraction angiography and road mapping on vascular and bleeding complications after transfemoral transcatheter aortic valve implantation.

    Science.gov (United States)

    El-Mawardy, Mohamed; Schwarz, Bettina; Landt, Martin; Sulimov, Dmitriy; Kebernik, Julia; Allali, Abdelhakim; Becker, Bjoern; Toelg, Ralph; Richardt, Gert; Abdel-Wahab, Mohamed

    2017-01-20

    The use of large-diameter sheaths carries the risk of significant vascular and bleeding complications after transfemoral transcatheter aortic valve implantation (TAVI). In this analysis, we sought to assess the impact of a modified femoral artery puncture technique using digital subtraction angiography (DSA) and road mapping during transfemoral TAVI on periprocedural vascular and bleeding events. This is a retrospective analysis of transfemoral TAVI patients included in a prospective institutional database. The modified femoral artery puncture technique using DSA-derived road mapping guidance was introduced in October 2012. Before the introduction of this technique, vascular puncture was acquired based on an integration of angiographic data, the bony iliofemoral landmarks and a radiopaque object. Consecutive patients who underwent TAVI with the road mapping technique (RM group, n=160) were compared with consecutive patients who underwent TAVI without road mapping (control group, n=160) prior to its introduction. A standardised strategy of periprocedural anticoagulation was adopted in both groups as well as the use of a single suture-based closure device. All endpoints were defined according to the VARC-2 criteria for event definition. The mean age in the RM group was 80±7.7 years compared to 81±5.9 years in the control group (p=0.19), and females were equally distributed between both groups (63.1% vs. 58.1%, p=0.36). The baseline logistic EuroSCORE was 20.7±14.4% vs. 24.9±15.2% in the RM and control group, respectively (p=0.01). Notably, sheath size was significantly larger in the RM compared to the control group due to the more frequent use of the 20 Fr sheath (23.8% vs. 1.8%, proad map group but did not reach statistical significance (8.1% vs. 13.8%, p=0.1). Other forms of vascular and bleeding complications as well as all-cause mortality were comparable in both groups. A modified femoral artery puncture technique using DSA and road mapping was associated

  18. Evaluation of arterial diseases by intravenous digital angiography (IVSDA) and risk factors in patients with cerebrovascular disease

    International Nuclear Information System (INIS)

    Fukui, Toshiya

    1989-01-01

    Intravenous digital angiography (IVSDA) has been performed in 1,031 consecutive patients during the previous 4 years. Complications of IVSDA, such as coughing, dermal reaction, nausea and vomiting, occurred in 77 patients (7.5%). Among them, 234 patients with a definite diagnosis of cerebrovascular disease were entered onto this study. On the basis of findings of IVSDA, the patients were largely classified into six groups: internal carotid artery (ICA) occlusion, ICA stenosis, middle cerebral artery (MCA) occlusion, MCA stenosis, marked arterial elongation, and normal findings. A group of the patients with ICA occlusion was characterized by having sudden onset with less complicated hypertension. In this group, etiological factors seemed to be embolism, intra-atheromatic hemorrhage, and dissecting aneurysm, as well as atherosclerosis. Major risk factors were hypertension, smoking, diabetes mellitus, and ischemic heart disease for lesions of the main trunk; and severe hypertension, high hematocrit levels and elevated platelet aggregability for lesions of perforating and small cortical arteries and arterioles. In the case of arterial elongation, platelet aggregability elicited by ADP was not suppressed by antiplatelet agents. These patients need to receive intensive treatment to prevent relapse of the disease. (Namekawa, K)

  19. Carbon dioxide (CO{sub 2}) digital subtraction angiography. Evaluation of a new delivery system; Angiografia con anidride carbonica. Nuovo sistema di iniezione

    Energy Technology Data Exchange (ETDEWEB)

    Nicolini, A.; Lovaria, A.; Meregaglia, D. [Ospedale Maggiore IRCCS Policlinico, Milan (Italy). Dipt. di Scienze Radiologiche; Palatresi, S. [Ospedale Maggiore IRCCS Policlinico, Milan (Italy). Ist. di Clinica Medica Generale e Terapia Medica

    2000-02-01

    Purpose of this work is to evaluate the usefulness of a new carbon dioxide (CO{sub 2}) intravascular injection system in digital subtraction angiography. March 1998 to May 1999, 39 patients were submitted to digital subtraction angiography with CO{sub 2} injection by a new delivery system, CO{sub 2}-Angio set, OptiMed, Ettingen, Germany. The patients were 29 men and 10 women, whose age ranged 32 to 76 (mean: 47), 18 of them with absolute or relative contraindications to iodinated contrast media and 6 with poor diagnostic findings at previous conventional angiography. CO{sub 2} was used for comparison with iodinated contrast agents in 4 patients. It was studied the following vascular districts: renal arteries in 9 patients, portal vein in 18, lower limb arteries in 7, upper limb veins in 4. In 1 patient CO{sub 2} angiography was carried out for the diagnosis and interventional treatment, by transcatheter embolization, of a postbioptic arteriovenous renal fistula. During the procedure, arterial blood pressure, EKG status and oxygen saturation were monitored, and subjective sensations recorded in all patients. CO{sub 2} angiography provided adequate visualization of vascular districts and of abnormal findings in 32 cased (82%), while its results were considered insufficient for correct and complete assessment in 7 cases (18%). CO{sub 2}-Angio set delivery system has proved to be a simple and safe tool, particularly suitable for use in patients at risk for allergic reactions to iodinated contrast agents and in those with renal function impairment. Also, the system can help carry out some interventional procedures such as arteriovenous fistula embolization and trans jugular portosystemic shunting. [Italian] Scopo di questo articolo e' verificare la validita' e l'efficacia di un nuovo sistema di iniezione angiografico per anidride carbonica. Da marzo 1998 a maggio 1999 sono stati sottoposti ad angiografia con anidride carbonica mediante sistema non

  20. Radionuclide identification using subtractive clustering method

    Energy Technology Data Exchange (ETDEWEB)

    Farias, Marcos Santana, E-mail: msantana@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Instrumentacao e Confiabilidade Humana; Nedjah, Nadia, E-mail: nadia@eng.uerj.br [Departamento de Engenharia Eletronica e Telecomunicacoes. Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil); Mourelle, Luiza de Macedo, E-mail: ldmm@eng.uerj.br [Departamento de Engenharia de Sistemas e Computacao. Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil)

    2011-07-01

    Radionuclide identification is crucial to planning protective measures in emergency situations. This paper presents the application of a method for a classification system of radioactive elements with a fast and efficient response. To achieve this goal is proposed the application of subtractive clustering algorithm. The proposed application can be implemented in reconfigurable hardware, a flexible medium to implement digital hardware circuits. (author)

  1. Radionuclide identification using subtractive clustering method

    International Nuclear Information System (INIS)

    Farias, Marcos Santana; Mourelle, Luiza de Macedo

    2011-01-01

    Radionuclide identification is crucial to planning protective measures in emergency situations. This paper presents the application of a method for a classification system of radioactive elements with a fast and efficient response. To achieve this goal is proposed the application of subtractive clustering algorithm. The proposed application can be implemented in reconfigurable hardware, a flexible medium to implement digital hardware circuits. (author)

  2. Added Value of Bone Subtraction in Dual-energy Digital Radiography in the Detection of Pneumothorax: Impact of Reader Expertise and Medical Specialty.

    Science.gov (United States)

    Urbaneja, Ayla; Dodin, Gauthier; Hossu, Gabriela; Bakour, Omar; Kechidi, Rachid; Gondim Teixeira, Pedro; Blum, Alain

    2018-01-01

    This study aimed to determine the value of dual-energy thoracic radiography in the diagnosis of pneumothorax considering the reader's experience. Forty patients with a suspected pneumothorax, imaged with dual-energy chest radiographs, were divided into two groups: those with pneumothorax as the final diagnosis (n = 19) and those without (n = 21). The images were analyzed by 36 readers (5 interns, 16 residents, 15 senior physicians) for the presence or absence of pneumothorax during three readout sessions at 2-week intervals: standard images alone (session 1), dual-energy images with bone subtraction alone (session 2), and a combination of the two (session 3). The number of correct responses increased 13.3% between sessions 1 and 2 (P expertise. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  3. Digital fluoroscopy: Technique and applications for evaluating left ventricular function

    International Nuclear Information System (INIS)

    Higgins, C.B.; Norris, S.L.; Gerber, K.H.; Ashburn, W.L.; Slutsky, R.A.

    1985-01-01

    Central cardiovascular dynamics can be studied without cardiac catheterization by digital processing of fluoroscopic images of the heart obtained after central intravenous injection of contrast media. While digital subtraction angiography has been used for studying peripheral vasculature for several years, it is only recently that this technique has been applied for assessing cardiac morphology and physiology. The conversion of fluoroscopic x-ray data into a digital form has an added advantage for the study of the central cardiovascular system since it not only permits contrast enhancement of the images but also facilitates quantitative and functional analysis of the x-ray data. The several applications described in this chapter suggest that digital subtraction cardiovascular angiography will prove to be a powerful tool for studying cardiovascular physiology in animals and for evaluating heart disease in patients

  4. Evaluation of the hemodynamic effects of intravenous administration of ionic and nonionic contrast materials: implications for deriving physiologic measurements from computed tomography and digital cardiovascular imaging

    International Nuclear Information System (INIS)

    Higgins, C.B.; Berber, K.H.; Mattrey, R.F.; Slutsky, R.A.

    1982-01-01

    The effects of intravenous injection of an ionic contrast material (Renografin-76 [meglumine sodium diatrizoate]) on left ventricular pressure, internal diameter, and wall thickness, and on coronary and femoral hemodynamics were compared with those of a hydrolytically stable nonionic contrast material (iohexol). Renografin-76 caused drastic biphasic changes in left ventricular pressure and dp/dt (rate of change of left ventricular pressure), and moderate changes in end systolic dimension. Iohexol caused little or no change in left ventricular pressure and dimensions. In addition, Renografin-76 caused marked arterial hypotension and large increases in coronary and femoral blood lows, while iohexol caused no significant change in arterial pressure and coronary blood flow, and a mild increase in femoral blood flow. Based on these findings, it is concluded that iohexol is preferable to standard ionic contrast material for deriving basal physiologic information from computed tomographic and digital vascular studies

  5. Entropy-Based Dark Frame Subtraction

    OpenAIRE

    Goesele, Michael; Heidrich, Wolfgang; Seidel, Hans-Peter

    2001-01-01

    Noise due to dark current is a serious limitation for taking long exposure time images with a CCD digital camera. Current solutions have serious drawbacks: interpolation of pixels with high dark current leads to smoothing effects or other artifacts -- especially if a large number of pixels are corrupted. Due to the exponential temperature dependence of the dark current, dark frame subtraction works best for temperature controlled high end CCD imaging systems. On the ...

  6. Technical innovation: Multidimensional computerized software enabled subtraction computed tomographic angiography.

    Science.gov (United States)

    Bhatia, Mona; Rosset, Antoine; Platon, Alexandra; Didier, Dominique; Becker, Christoph D; Poletti, Pierre-Alexandre

    2010-01-01

    Computed tomographic angiography (CTA) is a frequent noninvasive alternative to digital subtraction angiography. We previously reported the development of a new subtraction software to overcome limitations of adjacent bone and calcification in CT angiographic subtraction. Our aim was to further develop and improve this fast and automated computerized software, universally available for free use and compatible with most CT scanners, thus enabling better delineation of vascular structures, artifact reduction, and shorter reading times with potential clinical benefits. This computer-based free software will be available as an open source in the next release of OsiriX at the Web site http://www.osirix-viewer.com.

  7. Advanced techniques for digital angiography of the heart

    International Nuclear Information System (INIS)

    Hoehne, K.H.; Obermoeller, U.; Riemer, M.; Witte, G.

    1987-01-01

    Digital angiography is widely considered as being simply a method in which images taken at different times are subtracted from each other. This paper presents some techniques which are performed in the frequency domain after the application of the Fourier Transform. Nonselective bypass angiograms and intravenous ventriculograms are taken as examples to show that simple procedures utilizing these techniques exhibit the advantages of improved signal to noise ratio in the subtraction images, reduction of motion artefacts, easy application of phase-synchronous subtraction, integration and quantitative visualization of blood propagation. Furthermore it is shown that the storage of the angiographic image sequence as Fourier-coefficients leads to data compression and convenient data access in an image database. (Auth.)

  8. Magnetic resonance evaluation of renal artery stenosis in a swine model: performance of low-dose gadobutrol versus gadoterate meglumine in comparison with digital subtraction intra-arterial catheter angiography.

    Science.gov (United States)

    Morelli, John N; Runge, Val M; Ai, Fei; Zhang, Wei; Li, Xiaoming; Schmitt, Peter; McNeal, Gary; Miller, Matthew; Lennox, Mark; Wusten, Oliver; Schoenberg, Stefan O; Attenberger, Ulrike I

    2012-06-01

    The aim of this study was to compare low-dose imaging with gadobutrol and gadoterate meglumine (Gd-DOTA) for evaluation of renal artery stenosis with 3-T magnetic resonance angiography (MRA) in a swine model. A total of 12 experimental animals were evaluated using equivalently dosed gadobutrol and Gd-DOTA for time-resolved and static imaging. For time-resolved imaging, the time-resolved imaging with stochastic trajectories (TWIST) technique (temporal footprint, 4.4 seconds) was used; a dose of 1 mL of gadobutrol was injected at 2 mL/s and a dose of 2 mL of Gd-DOTA was injected at both 2 and 4 mL/s. For a separate static acquisition, doses were doubled. The static scans were used for stenosis gradation and the time-resolved scans for comparison of enhancement dynamics, signal-to-noise ratio (SNR), and qualitative assessments. The average magnitude of difference in the stenosis measurements with static gadobutrol scans relative to digital subtraction intra-arterial catheter angiography (mean [SD], 7.4% [5.6%]) was less than with both the 2 mL/s (10.6% [6.2%]) and 4 mL/s (11.5% [7.8%]) Gd-DOTA MRA protocols. On time-resolved scans, peak signal-to-noise ratio was greatest with the gadobutrol protocol (P < 0.05), and the gadobutrol TWIST scan was preferred to the TWIST Gd-DOTA scan in terms of image quality and stenosis visualization in every case for every reader. Low-dose gadobutrol (~0.05 mmoL/kg) contrast-enhanced MRA results in improved accuracy of renal artery stenosis assessments relative to equivalently dosed Gd-DOTA at 3 T.

  9. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

    International Nuclear Information System (INIS)

    Burgmans, M.C.; Too, C.W.; Kao, Y.H.; Goh, A.S.W.; Chow, P.K.H.; Tan, B.S.; Tay, K.H.; Lo, R.H.G.

    2012-01-01

    Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

  10. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

    Energy Technology Data Exchange (ETDEWEB)

    Burgmans, M.C., E-mail: mburgmans@hotmail.com [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Too, C.W., E-mail: too.chow.wei@singhealth.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Kao, Y.H., E-mail: yung.h.kao@gmail.com [Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Goh, A.S.W., E-mail: anthony.goh.s.w@sgh.com.sg [Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Chow, P.K.H., E-mail: gsupc@singnet.com.sg [Department of General Surgery, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Office of Clinical Sciences, Duke-NUS Graduate Medical School Singapore, 8 College Road, Singapore 169857 (Singapore); Department of Surgical Oncology, National Cancer Center Singapore, 11 Hospital Drive, Singapore 169610 (Singapore); Tan, B.S., E-mail: tan.bien.soo@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Tay, K.H., E-mail: tay.kiang.hiong@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Lo, R.H.G., E-mail: richard.lo.h.g@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore)

    2012-12-15

    Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

  11. [Comparative study of X-ray digital tomosynthesis imaging based on intravenous urography and unenhanced multidetector-row computerized tomography in urinary calculi].

    Science.gov (United States)

    Tuerdi, Batuer; Wang, Hui; Huo, Zhong; Abula, Gulipiyan; Mahemuti, Biekemulati; Abulizi, Maihemuti

    2014-04-22

    To evaluate the clinical application value of X-ray digital DTSynthesis (DTS) based on IVU (Intravenous Urography)in urinary calculi contrasted with unenhanced multidetector-row computerized tomography. 75 patients suspected of urinary calculi underwent IVU, DTS based on IVU and UMDCT. The diagnostic sensitivity, specificity, accuracy, positive predictive value and negative predictive of the three imaging ways were acquired according to operations, respectively. Chi-square test was used to evaluate the difference among the three ways. In 75 cases, 60 cases were proved to be urinary calculi. The diagnostic sensitivity, specificity, accuracy, positive predictive value and negative predictive of IVU, DTS based on IVU,UMDCT is 70.0%, 73.3%, 70.7%, 91.3%, 37.9%; 91.7%, 86.7%, 90.7%, 96.5%, 72.2%; 96.7%, 86.7%, 94.7%, 96.7%, 86.7%, respectively.No significant differences between DTS based on IVU and UMDCT were found in sensitivity, specificity, accuracy, positive predictive value and negative predictive. Both cases are better than IVU in diagnostic ability. There is no significant difference in diagnostic ability of urinary calculi between DTS and UMDCT. DTS can be used as a routine imaging technique in diagnosis and follow up of urinary calculi.

  12. Digital subtraction angiography for lower extremity phlebography

    International Nuclear Information System (INIS)

    Yokoyama, Kunihiko; Nakashima, Noriko; Takata, Yasunori; Hashimoto, Shozo.

    1989-01-01

    DSA was applied to the lower extremity phlebography on 21 cases (36 legs). The patient lay in the supine position and a tourniquet was placed around the ankle. Forty ml of contrast medium, diluted to 25% of the original concentration with normal saline, was injected into the dorsal vein of the foot. The anterior tibial vein, posterior tibial vein, peroneal vein and muscular vein of the calf were identified in 24(63.2%), 36(94.7%), 37(97.4%) and 7 legs (18.4%), respectively. The poor opacification of the anterior tibial vein was attributed partly to the compression effect of the tourniquet. The abnormal findings were deep vein thrombosis (5 legs), reflux from the deep to the superficial vein (14 legs) and irregularity of the vein wall (16 legs). The superficial varicose veins were not demonstrated in DSA phlebography. The examination was comfortable because the patient position was supine and the dilute contrast medium caused no burning sensation. We believe that DSA phelobography is a safe and useful method for diagnosing the deep venous system disorders. (author)

  13. Digital subtraction angiography for lower extremity phlebography

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Kunihiko; Nakashima, Noriko; Takata, Yasunori; Hashimoto, Shozo.

    1989-04-01

    DSA was applied to the lower extremity phlebography on 21 cases (36 legs). The patient lay in the supine position and a tourniquet was placed around the ankle. Forty ml of contrast medium, diluted to 25% of the original concentration with normal saline, was injected into the dorsal vein of the foot. The anterior tibial vein, posterior tibial vein, peroneal vein and muscular vein of the calf were identified in 24(63.2%), 36(94.7%), 37(97.4%) and 7 legs (18.4%), respectively. The poor opacification of the anterior tibial vein was attributed partly to the compression effect of the tourniquet. The abnormal findings were deep vein thrombosis (5 legs), reflux from the deep to the superficial vein (14 legs) and irregularity of the vein wall (16 legs). The superficial varicose veins were not demonstrated in DSA phlebography. The examination was comfortable because the patient position was supine and the dilute contrast medium caused no burning sensation. We believe that DSA phelobography is a safe and useful method for diagnosing the deep venous system disorders. (author).

  14. Subtraction and dynamic MR images of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Yoshitaka; Aoki, Manabu; Harada, Junta (Jikei Univ., Tokyo (Japan). School of Medicine)

    1993-04-01

    The purpose of this study was to evaluate the diagnostic effectiveness of subtraction and dynamic MR imaging in patients with breast masses. In 23 breast cancers and six fibroadenomas, spin echo T1 images were obtained at 0.2 Tesla before and every minute after intravenous injection of Gd-DTPA (0.1 or 0.2 mmol/kg). Subtraction images were obtained sequentially on the CRT monitor. All breast masses were enhanced after gadolinium and stood out as bright lesions on subtraction images. The tumor margin and its extension were more precisely evaluated on subtraction MR images than on conventional postcontrast MR images. Breast cancer showed a characteristic time-intensity curve with an early peak, in contrast to fibroadenoma, which showed a gradual increase in signal intensity. Subtraction MR imaging is a simple method for the evaluation of breast masses, and further, the time-intensity curve obtained by dynamic study is helpful in the differential diagnosis of lesions. (author).

  15. Subtraction and dynamic MR images of breast cancer

    International Nuclear Information System (INIS)

    Murakami, Yoshitaka; Aoki, Manabu; Harada, Junta

    1993-01-01

    The purpose of this study was to evaluate the diagnostic effectiveness of subtraction and dynamic MR imaging in patients with breast masses. In 23 breast cancers and six fibroadenomas, spin echo T1 images were obtained at 0.2 Tesla before and every minute after intravenous injection of Gd-DTPA (0.1 or 0.2 mmol/kg). Subtraction images were obtained sequentially on the CRT monitor. All breast masses were enhanced after gadolinium and stood out as bright lesions on subtraction images. The tumor margin and its extension were more precisely evaluated on subtraction MR images than on conventional postcontrast MR images. Breast cancer showed a characteristic time-intensity curve with an early peak, in contrast to fibroadenoma, which showed a gradual increase in signal intensity. Subtraction MR imaging is a simple method for the evaluation of breast masses, and further, the time-intensity curve obtained by dynamic study is helpful in the differential diagnosis of lesions. (author)

  16. The Use of Procedural Knowledge in Simple Addition and Subtraction Problems

    Science.gov (United States)

    Fayol, Michel; Thevenot, Catherine

    2012-01-01

    In a first experiment, adults were asked to solve one-digit additions, subtractions and multiplications. When the sign appeared 150 ms before the operands, addition and subtraction were solved faster than when the sign and the operands appeared simultaneously on screen. This priming effect was not observed for multiplication problems. A second…

  17. Background subtraction theory and practice

    CERN Document Server

    Elgammal, Ahmed

    2014-01-01

    Background subtraction is a widely used concept for detection of moving objects in videos. In the last two decades there has been a lot of development in designing algorithms for background subtraction, as well as wide use of these algorithms in various important applications, such as visual surveillance, sports video analysis, motion capture, etc. Various statistical approaches have been proposed to model scene backgrounds. The concept of background subtraction also has been extended to detect objects from videos captured from moving cameras. This book reviews the concept and practice of back

  18. Intravenous Leiomyomatosis

    African Journals Online (AJOL)

    Hemostasis was well achieved. The tumor weighed 6.7 kg. The postoperative course. Intravenous Leiomyomatosis. Narayanaswamy Mariyappa, Uday Kumar Manikyam1, Dinesh Krishnamurthy2, Preeti K,. Yamini Agarwal, Prakar U. Departments of Obstetrics and Gynaecology, 1Pathology and 2Anaesthesia, Sri Devaraj ...

  19. Developing a Model to Support Students in Solving Subtraction

    Directory of Open Access Journals (Sweden)

    Nila Mareta Murdiyani

    2013-01-01

    Full Text Available Subtraction has two meanings and each meaning leads to the different strategies. The meaning of “taking away something” suggests a direct subtraction, while the meaning of “determining the difference between two numbers” is more likely to be modeled as indirect addition. Many prior researches found that the second meaning and second strategy rarely appeared in the mathematical textbooks and teacher explanations, including in Indonesia. Therefore, this study was conducted to contribute to the development of a local instruction theory for subtraction by designing instructional activities that can facilitate first grade of primary school students to develop a model in solving two digit numbers subtraction. Consequently, design research was chosen as an appropriate approach for achieving the research aim and Realistic Mathematics Education (RME was used as a guide to design the lesson. This study involved 6 students in the pilot experiment, 31 students in the teaching experiment, and a first grade teacher of SDN 179 Palembang. The  result of this study shows that the beads string could bridge students from the contextual problems (taking ginger candies and making grains bracelets to the use of the empty number line. It also shows that the empty number line could promote students to  use different strategies (direct subtraction, indirect addition, and indirect subtraction in solving subtraction problems. Based on these findings, it is recommended to apply RME in the teaching learning process to make it more meaningful for students. Keywords: Subtraction, Design Research, Realistic Mathematics Education, The Beads String, The Empty Number Line DOI: http://dx.doi.org/10.22342/jme.4.1.567.95-112

  20. Synchrotron-based intravenous cerebral angiography in a small animal model

    International Nuclear Information System (INIS)

    Kelly, Michael E; Schueltke, Elisabeth; Fiedler, Stephan; Nemoz, Christian; Guzman, Raphael; Corde, Stephanie; Esteve, Francois; LeDuc, Geraldine; Juurlink, Bernhard H J; Meguro, Kotoo

    2007-01-01

    K-edge digital subtraction angiography (KEDSA), a recently developed synchrotron-based technique, utilizes monochromatic radiation and allows acquisition of high-quality angiography images after intravenous administration of contrast agent. We tested KEDSA for its suitability for intravenous cerebral angiography in an animal model. Adult male New Zealand rabbits were subjected to either angiography with conventional x-ray equipment or synchrotron-based intravenous KEDSA, using an iodine-based contrast agent. Angiography with conventional x-ray equipment after intra-arterial administration of contrast agent demonstrated the major intracranial vessels but no smaller branches. KEDSA was able to visualize the major intracranial vessels as well as smaller branches in both radiography mode (planar images) and tomography mode. Visualization was achieved with as little as 0.5 ml kg -1 of iodinated contrast material. We were able to obtain excellent visualization of the cerebral vasculature in an animal model using intravenous injection of contrast material, using synchrotron-based KEDSA

  1. Comparison between digital subtraction angiography and magnetic resonance angiography in investigation of nonlacunar ischemic stroke in young patients: preliminary results Comparação entre arteriografia digital e angioressonância na investigação de acidente vascular cerebral isquêmico não-lacunar em pacientes jovens: resultados preliminares

    Directory of Open Access Journals (Sweden)

    Adriana Bastos Conforto

    2006-06-01

    Full Text Available PURPOSE: We preliminarily investigated the relevance of performing digital subtraction angiography (DSA in addition to magnetic resonance angiography (MRA in definition of ischemic stroke etiology in young patients. METHOD: DSAs and MRAs from 17 young patients with nonlacunar ischemic stroke were blindly analyzed and their impact on stroke management was evaluated. RESULTS: Etiologies were the same considering results of either DSA or MRA in 12/17 cases. In 15/17 patients no changes would have been made in treatment, regardless of the modality of angiography considered. CONCLUSION: These preliminary results suggest that DSA may be redundant in two thirds of ischemic strokes in young patients. Further larger prospective studies are necessary to determine indications of DSA in this age group.PROPÓSITO DO ESTUDO: Investigar de forma preliminar a relevância da realização de angiografia digital (AD adicionalmente a angioressonância (AR na definição de etiologias de acidente vascular cerebral isquêmico (AVCI em pacientes jovens. MÉTODO: ADs e ARs de 17 pacientes jovens com AVCIs não-lacunares foram analisadas. Avaliamos o impacto destes exames no manejo clínico dos casos. RESULTADOS: Em 12/17 casos, as etiologias dos AVCIs de acordo com os resultados de AD ou de AR foram idênticas. Em 15/17 pacientes, nenhuma mudança de conduta terapêutica seria realizada, independentemente da modalidade de exame considerada. CONCLUSÃO: Estes resultados preliminares sugerem que os resultados da AD podem ser redundantes em relação à AR em até dois terços dos pacientes jovens com AVCI. Estudos prospectivos maiores são necessários para otimizar o estabelecimento de indicações de AD nesta faixa etária.

  2. Behavior Subtraction applied to radar

    NARCIS (Netherlands)

    Rossum, W.L. van; Caro Cuenca, M.

    2014-01-01

    An algorithm developed for optical images has been applied to radar data. The algorithm, Behavior Subtraction, is based on capturing the dynamics of a scene and detecting anomalous behavior. The radar application is the detection of small surface targets at sea. The sea surface yields the expected

  3. Color Addition and Subtraction Apps

    Science.gov (United States)

    Ruiz, Frances; Ruiz, Michael J.

    2015-01-01

    Color addition and subtraction apps in HTML5 have been developed for students as an online hands-on experience so that they can more easily master principles introduced through traditional classroom demonstrations. The evolution of the additive RGB color model is traced through the early IBM color adapters so that students can proceed step by step…

  4. Overview of clinical intravenous coronary angiography both in Japan and at ESRF

    International Nuclear Information System (INIS)

    Ohtsuka, S.; Hyodo, K.; Jin, W.; Takeda, T.; Maruhashi, A.; Yamaguchi, I.; Ando, M.

    2005-01-01

    The clinical program of intravenous coronary angiography (IVCAG) using synchrotron radiation is moving on at the ESRF and at the KEK. Since the X-ray optics and types of detectors are different depending on the needs of technology, the ESRF adopts dual-energy digital subtraction system and the KEK does single-energy two-dimensional dynamic imaging system. A contrast agent is injected intravenously and the image sequence is started. The former technique enhances the image contrast of the coronary arteries in spite of intravenous injection of a contrast agent; whereas, the latter technique produces excellent temporal resolution for imaging of moving objects such as the coronary arteries and the left ventricle. So, the obtained image, the radiation dose, the examination time, and other details are different between the two facilities. Both systems sufficiently visualize the right coronary artery disease, even after coronary angioplasty or coronary artery bypass grafting. Also, the two-dimensional dynamic IVCAG permits the visualization of the left coronary arteries. The coronary morphology obtained by the IVCAG, was almost completely coincident with the results of selective CAG. Accordingly, the IVCAG is clinically validated and useful for the screening and the follow-up of coronary artery disease. However, as some portions of the left circumflex coronary artery are overlapped by the left ventricle, more contrivance is required and its imaging should be improved in future

  5. A New Algorithm for the Subtraction Games

    OpenAIRE

    He, Guanglei; Qin, Zhihui

    2012-01-01

    Subtraction games is a class of combinatorial games. It was solved since the Sprague-Grundy Theory was put forward. This paper described a new algorithm for subtraction games. The new algorithm can find win or lost positions in subtraction games. In addition, it is much simpler than Sprague-Grundy Theory in one pile of the games.

  6. Contrast-enhanced digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Dromain, Clarisse [Department of Radiology, Institut Gustave-Roussy, 39, rue Camille Desmoulins, 94805 Villejuif Cedex (France)], E-mail: dromain@igr.fr; Balleyguier, Corinne; Adler, Ghazal [Department of Radiology, Institut Gustave-Roussy, 39, rue Camille Desmoulins, 94805 Villejuif Cedex (France); Garbay, Jean Remi [Department of Surgery, Institut Gustave-Roussy, 39, rue Camille Desmoulins, 94805 Villejuif Cedex (France); Delaloge, Suzette [Department of Medicine, Institut Gustave-Roussy, 39, rue Camille Desmoulins, 94805 Villejuif Cedex (France)

    2009-01-15

    CEDM is a recent development of digital mammography using the intra-venous injection of an iodinated contrast agent in conjunction with a mammography examination. Two techniques have been developed to perform CEDM examinations: the temporal subtraction technique with acquisition of high-energy images before and after contrast medium injection and the dual energy technique with acquisition of a pair of low and high-energy images only after contrast medium injection. The temporal subtraction technique offered the possibility to analyze the kinetic curve of enhancement of breast lesions, similarly to breast MRI. The dual energy technique do not provide information about the kinetic of tumor enhancement but allows the acquisition of multiples views of the same breast or bilateral examination and is less sensitive to patient motion than temporal CEDM. Initial clinical experience has shown the ability of CEDM to map the distribution of neovasculature induced by cancer using mammography. Moreover, previous studies have shown a superiority of MX + CEDM, either for the assessment of the probability of malignancy than for BIRADS assessment comparing to MX alone. The potential clinical applications are the clarification of mammographically equivocal lesions, the detection of occult lesions on standard mammography, particularly in dense breast, the determination of the extent of disease, the assessment of recurrent disease and the monitoring of the response to chemotherapy. CEDM should result in a simple way to enhance the detection and the characterization of breast lesions.

  7. Dual-energy subtraction radiography of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-06-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses.

  8. Temporal subtraction technique for detection of subtle anomalies on temporally sequential bone-subtracted chest radiographs by energy subtraction

    International Nuclear Information System (INIS)

    Sanada, Shigeru; Kobayashi, Takeshi; Yoshida, Megumi; Takashima, Tsutomu; Matsui, Takeshi

    2000-01-01

    We developed a temporal subtraction technique for the detection of subtle anomalies on temporally sequential bone-subtracted chest radiographs (soft tissue images) by energy subtraction. To recognize the temporal changes in a current soft tissue image in comparison with those in a previous soft tissue image, we attempted to enhance the changes by a difference image processing technique. The lung markings were enhanced by the first derivative filter. The image registration for the lung markings on both images by the sequential similarity detection algorithm (SSDA) method was then employed. The soft tissue image provided by the energy subtraction technique was excellent in its detection of subtle abnormalities in the lung, and this method was able to detect subtle abnormalities such as infiltrates and nodules missed in screening. It was suggested that this temporal subtraction technique improves accuracy when radiologists diagnose soft tissue chest images by x-ray energy subtraction. (author)

  9. 99mTc-RBC subtraction scintigraphy

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru

    1994-01-01

    Sequential abdominal scintigrams with 99m Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author)

  10. New Noise Subtraction Methods in Lattice QCD

    OpenAIRE

    Baral, Suman; Wilcox, Walter; Morgan, Ronald B.

    2016-01-01

    Noise subtraction techniques can help reduce the statistical uncertainty in the extraction of hard to detect signals. We describe new noise subtraction methods in Lattice QCD which apply to disconnected diagram evaluations. Some of the noise suppression techniques include polynomial quark matrix methods, eigenspectrum deflation methods, and combination methods. Our most promising technique combines polynomial and Hermitian deflation subtraction methods. The overall goal is to improve the effi...

  11. Statistically tuned Gaussian background subtraction technique for ...

    Indian Academy of Sciences (India)

    Keywords. Tuning factor; background segmentation; unmanned aerial vehicle; aerial surveillance; thresholding. Abstract. Background subtraction is one of the efficient techniques to segment the targets from non-informative background of a video. The traditional background subtraction technique suits for videos with static ...

  12. Addition and Subtraction, and Algorithms in General

    Science.gov (United States)

    Fielker, David

    2007-01-01

    The juxtaposition of articles by Ian Thompson and Ian Sugarman in "MT202" on addition and subtraction respectively engendered some bemused thoughts in this author, who for some years has been sheltered from controversy by retirement. In this article, Fielker shares some thoughts on addition and subtraction raised by Thompson and Sugarman in their…

  13. Subtraction radiography of interradicular bone lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kullendorf, B.; Groendahl, K.; Rohlin, M.; Nilsson, M. (Lund Univ., Malmoe (Sweden))

    1992-10-01

    Subtraction and conventional radiography were evaluated for their diagnostic potential to assess interradicular bone lesions in the mandibular premolar region. Both conventional radiographs and subtraction images were interpreted by 10 observers. The receiver-operating characteristic technique was used to compare the two techniques. The diagnostic validity was higher for the subtraction technique, both for lesions confined to cancellous bone and for lesions including the cortical bone, than for the conventional technique. For bone defects confined to cancellous bone the diagnostic accuracy was lower than those reported from periapical bone lesion irrespective of whether subtraction or conventional radiography was used. It is concluded that subtraction radiography improves the detectability of bone lesions, shallow ones in particular. Lesions in the interradicular bone are more difficult to detect than those in the periapical bone. 26 refs., 3 figs., 2 tabs.

  14. Subtraction radiography of interradicular bone lesions

    International Nuclear Information System (INIS)

    Kullendorf, B.; Groendahl, K.; Rohlin, M.; Nilsson, M.

    1992-01-01

    Subtraction and conventional radiography were evaluated for their diagnostic potential to assess interradicular bone lesions in the mandibular premolar region. Both conventional radiographs and subtraction images were interpreted by 10 observers. The receiver-operating characteristic technique was used to compare the two techniques. The diagnostic validity was higher for the subtraction technique, both for lesions confined to cancellous bone and for lesions including the cortical bone, than for the conventional technique. For bone defects confined to cancellous bone the diagnostic accuracy was lower than those reported from periapical bone lesion irrespective of whether subtraction or conventional radiography was used. It is concluded that subtraction radiography improves the detectability of bone lesions, shallow ones in particular. Lesions in the interradicular bone are more difficult to detect than those in the periapical bone. 26 refs., 3 figs., 2 tabs

  15. Compressive Sensing for Background Subtraction

    Science.gov (United States)

    2009-12-20

    i) reconstructing an image using only a single optical pho- todiode (infrared, hyperspectral, etc.) along with a digital micromirror device (DMD...NSF CCF-0431150, ONR N00014-07-1-0936,AFOSR FA9550-07-1-0301,AROW911NF-07-1-0502,AROMURI W311NF-07-1-0185, and the Texas Instruments Leadership

  16. Optimization of background subtraction for image enhancement

    Science.gov (United States)

    Venetsky, Larry; Boczar, Ross; Lee-Own, Robert

    2013-05-01

    Analysis of foreground objects in scenery via image processing often involves a background subtraction process. This process aims to improve blob (connected component) content in the image. Quality blob content is often needed for defining regions of interest for object recognition and tracking. Three techniques are examined which optimize the background to be subtracted - genetic algorithm, an analytic solution based on convex optimization, and a related application of the CVX solver toolbox. These techniques are applied to a set of images and the results are compared. Additionally, a possible implementation architecture that uses multiple optimization techniques with subsequent arbitration to produce the best background subtraction is considered.

  17. Subarachnoid hemorrhage: role of subtraction CT angiography in etiological diagnosis and pretreatment planning.

    Science.gov (United States)

    Li, K; Wei, X; Lv, F; Li, Q; Xie, P

    2014-12-01

    Subarachnoid hemorrhage (SAH) is a deleterious cerebrovascular disorder that requires prompt etiological diagnosis. We wished to evaluate the diagnostic performance of the latest generation 3D subtraction CT angiography (CTA) in etiological diagnosis and pretreatment planning of patients with suspected SAH. A total of 88 patients were included in our study and underwent both 3D subtraction CTA and digital subtraction angiography (DSA) examinations. The 3D subtraction CTA images were reviewed by two independent readers who were blinded to the results of DSA. Sensitivity, specificity, positive and negative predictive values of 3D subtraction CTA were calculated on a per-patient basis. The possibility for surgical treatment was also evaluated based on information provided by CTA alone. According to DSA results, 72 patients were diagnosed with ruptured intracranial aneurysms, 5 patients with arteriovenous malformations, and no lesion was detected in 11 patients. Sensitivity, specificity, positive predictive value and negative predictive values of CTA for etiological evaluation of SAH were all 100%. Correct pretreatment decision was made in 67 of 70 patients based on the CTA measurements alone. THE results of our study indicate that 3D subtraction CTA is an accurate, fast and non-invasive imaging modality that is equal to DSA in etiological evaluation and pretreatment planning of patients with suspected SAH. It may replace DSA as the first step imaging method in patients with suspected SAH, while DSA should still be reserved for case of uncertainty.

  18. Distinct representations of subtraction and multiplication in the neural systems for numerosity and language

    Science.gov (United States)

    Prado, Jérôme; Mutreja, Rachna; Zhang, Hongchuan; Mehta, Rucha; Desroches, Amy S.; Minas, Jennifer E.; Booth, James R.

    2010-01-01

    It has been proposed that recent cultural inventions such as symbolic arithmetic recycle evolutionary older neural mechanisms. A central assumption of this hypothesis is that the degree to which a pre-existing mechanism is recycled depends upon the degree of similarity between its initial function and the novel task. To test this assumption, we investigated whether the brain region involved in magnitude comparison in the intraparietal sulcus (IPS), localized by a numerosity comparison task, is recruited to a greater degree by arithmetic problems that involve number comparison (single-digit subtractions) than by problems that involve retrieving facts from memory (single-digit multiplications). Our results confirmed that subtractions are associated with greater activity in the IPS than multiplications, whereas multiplications elicit greater activity than subtractions in regions involved in verbal processing including the middle temporal gyrus and inferior frontal gyrus that were localized by a phonological processing task. Pattern analyses further indicated that the neural mechanisms more active for subtraction than multiplication in the IPS overlap with those involved in numerosity comparison, and that the strength of this overlap predicts inter-individual performance in the subtraction task. These findings provide novel evidence that elementary arithmetic relies on the co-option of evolutionary older neural circuits. PMID:21246667

  19. Intentional intravenous mercury injection

    African Journals Online (AJOL)

    In this case report, intravenous complications, treatment strategies and possible ... Mercury toxicity is commonly associated with vapour inhalation or oral ingestion, for which there exist definite treatment options. Intravenous mercury ... personality, anxiousness, irritability, insomnia, depression and drowsi- ness.[1] However ...

  20. Digital imaging in diagnostic radiology

    International Nuclear Information System (INIS)

    Newell, J.D. Jr.; Kelsey, C.A.

    1990-01-01

    This monograph on digital imaging provides a basic overview of this field at the present time. This paper covers clinical application, including subtraction angiography; chest radiology; genitourinary, gastrointestinal, and breast radiology; and teleradiology. The chest section also includes an explanation of multiple beam equalization radiography. The remaining chapters discuss some of the technical aspects of digital radiology. It includes the basic technology of digital radiography, image compression, and reconstruction information on the economics of digital radiography

  1. Digital subtraction angiography in patients with Marfan's syndrome

    International Nuclear Information System (INIS)

    Rauber, K.; Riemann, H.

    1987-01-01

    Marfan's syndrome is a rare inborn error of metabolism. Marfan patients are prone to aneurysms of the ascending aorta and run a high risk of rupture of the aortic arch. The diameter of the aneurysm is the most important predictor of the risk and therefore the leading point for surgical interventions. IV and IA-DSA according to our experiences are simple and effective methods in pre- and postoperative evaluation of patients with the syndrome. (orig.) [de

  2. Fourier transform profilometry by using digital dc subtraction

    Science.gov (United States)

    Wongjarern, J.; Widjaja, J.; Sangpech, W.; Thongdee, N.; Santisoonthornwat, P.; Traisak, O.; Chuamchaitrakool, P.; Meemon, P.

    2014-06-01

    A new method for eliminating unwanted background of Fourier transform profilometry (FTP) by using simple dc bias and background eliminations from the deformed grating images is proposed. The proposed method has an advantage over a conventional FTP in that the 3-D object profile can be accurately measured although original fundamental spectra are corrupted by a zeroth-order spectrum. Experimental verifications of the proposed method are presented.

  3. Degos' syndrome. Detection of intestinal lesion by digital subtraction angiography

    International Nuclear Information System (INIS)

    Bilbao, J.I.; Garcia Delgado, F.; Idoate, M.; Arejola, J.M.; Aquerreta, D.; Otero, M.

    1986-01-01

    Degos' syndrom consists in a generalized vasculitis with frequent affectation of the gut and the skin. The arteriographic findings in a patient with the diagnosis of Degos' syndroms and severe affectation of the gut are reported [fr

  4. Construction of Differential-Methylation Subtractive Library

    Directory of Open Access Journals (Sweden)

    Wei Hu

    2014-01-01

    Full Text Available Stress-induced ROS changes DNA methylation patterns. A protocol combining methylation-sensitive restriction endonuclease (MS-RE digestion with suppression subtractive hybridization (SSH to construct the differential-methylation subtractive library was developed for finding genes regulated by methylation mechanism under cold stress. The total efficiency of target fragment detection was 74.64%. DNA methylation analysis demonstrated the methylation status of target fragments changed after low temperature or DNA methyltransferase inhibitor treatment. Transcription level analysis indicated that demethylation of DNA promotes gene expression level. The results proved that our protocol was reliable and efficient to obtain gene fragments in differential-methylation status.

  5. Polygon Subtraction in 2 or 3 Dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, John E.

    2013-10-01

    When searching for computer code to perform the ubiquitous task of subtracting one polygon from another, it is difficult to find real examples and detailed explanations. This paper outlines the step-by-step process necessary to accomplish this basic task.

  6. Statistically tuned Gaussian background subtraction technique for ...

    Indian Academy of Sciences (India)

    The non-parametric background modelling approach proposed by Martin Hofmann et al (2012) involves modelling of foreground by the history of recently ... background subtraction system with mixture of Gaussians, deviation scaling factor and max– min background model for outdoor environment. Selection of detection ...

  7. Genetic sequences derived from suppression subtractive ...

    African Journals Online (AJOL)

    Leaf scald disease (LSD) is caused by the Gram-negative bacterium, Xanthomonas albilineans. Genomic DNA from X. albilineans and Xanthomonas hyacinthi were analyzed by suppression subtractive hybridization (SSH) using X. albilineans as the tester from which unique sequences were sought and X. hyacinthi as the ...

  8. Probabilistic Model-based Background Subtraction

    DEFF Research Database (Denmark)

    Krüger, Volker; Anderson, Jakob; Prehn, Thomas

    2005-01-01

    Usually, background subtraction is approached as a pixel-based process, and the output is (a possibly thresholded) image where each pixel reflects, independent from its neighboring pixels, the likelihood of itself belonging to a foreground object. What is neglected for better output is the correl...

  9. Genetic sequences derived from suppression subtractive ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-06-17

    Jun 17, 2008 ... Genomic DNA from X. albilineans and Xanthomonas hyacinthi were analyzed by suppression subtractive ... Clone X. albilineans 12 showed 92% homology to the acetate repressor proteins and clone. X. albilineans 18 .... stranded DNA will be enriched for tester-specific DNA, as DNA fragments that are not ...

  10. Angiographic CT with intravenous contrast agent application for monitoring of intracranial flow diverting stents

    International Nuclear Information System (INIS)

    Saake, Marc; Struffert, Tobias; Goelitz, Philipp; Ott, Sabine; Doerfler, Arnd; Seifert, Frank; Ganslandt, Oliver

    2012-01-01

    Intracranial flow diverting devices are increasingly used to treat cerebral aneurysms. A reliable, non-invasive follow-up modality would be desirable. Our aim was to compare intra-arterial digital subtraction angiography (ia DSA) to angiographic computed tomography with intravenous contrast agent application (iv ACT) in the visualisation of flow diverting devices and aneurysm lumina. Follow-up monitoring by iv ACT (n = 36) and ia DSA (n = 25) in 14 patients treated with flow diverting devices for intracranial aneurysms was evaluated retrospectively. Images were evaluated by two neuroradiologists in anonymous consensus reading regarding the device deployment, wall apposition, neck coverage of the aneurysm, opacification of the vessel and device lumen, as well as the degree of aneurysm occlusion. Corresponding ia DSA and iv ACT images were scored identically in all patients regarding the stent deployment, wall apposition and neck coverage, as well as the degree of aneurysm occlusion and patency status of the device and parent artery. Opacification of the parent vessel lumen and perfused parts of the aneurysm was considered slightly inferior for iv ACT in comparison with ia DSA (seven of 36 cases), without impact on diagnosis. We demonstrated the feasibility and diagnostic value of iv ACT in follow-up imaging of intracranial flow diverting devices. Due to its high spatial resolution and non-invasive character, this novel technique might become a valuable imaging modality in these patients. (orig.)

  11. Subtracting and Fitting Histograms using Profile Likelihood

    CERN Document Server

    D'Almeida, F M L

    2008-01-01

    It is known that many interesting signals expected at LHC are of unknown shape and strongly contaminated by background events. These signals will be dif cult to detect during the rst years of LHC operation due to the initial low luminosity. In this work, one presents a method of subtracting histograms based on the pro le likelihood function when the background is previously estimated by Monte Carlo events and one has low statistics. Estimators for the signal in each bin of the histogram difference are calculated so as limits for the signals with 68.3% of Con dence Level in a low statistics case when one has a exponential background and a Gaussian signal. The method can also be used to t histograms when the signal shape is known. Our results show a good performance and avoid the problem of negative values when subtracting histograms.

  12. Hardware Implementation of a Bilateral Subtraction Filter

    Science.gov (United States)

    Huertas, Andres; Watson, Robert; Villalpando, Carlos; Goldberg, Steven

    2009-01-01

    A bilateral subtraction filter has been implemented as a hardware module in the form of a field-programmable gate array (FPGA). In general, a bilateral subtraction filter is a key subsystem of a high-quality stereoscopic machine vision system that utilizes images that are large and/or dense. Bilateral subtraction filters have been implemented in software on general-purpose computers, but the processing speeds attainable in this way even on computers containing the fastest processors are insufficient for real-time applications. The present FPGA bilateral subtraction filter is intended to accelerate processing to real-time speed and to be a prototype of a link in a stereoscopic-machine- vision processing chain, now under development, that would process large and/or dense images in real time and would be implemented in an FPGA. In terms that are necessarily oversimplified for the sake of brevity, a bilateral subtraction filter is a smoothing, edge-preserving filter for suppressing low-frequency noise. The filter operation amounts to replacing the value for each pixel with a weighted average of the values of that pixel and the neighboring pixels in a predefined neighborhood or window (e.g., a 9 9 window). The filter weights depend partly on pixel values and partly on the window size. The present FPGA implementation of a bilateral subtraction filter utilizes a 9 9 window. This implementation was designed to take advantage of the ability to do many of the component computations in parallel pipelines to enable processing of image data at the rate at which they are generated. The filter can be considered to be divided into the following parts (see figure): a) An image pixel pipeline with a 9 9- pixel window generator, b) An array of processing elements; c) An adder tree; d) A smoothing-and-delaying unit; and e) A subtraction unit. After each 9 9 window is created, the affected pixel data are fed to the processing elements. Each processing element is fed the pixel value for

  13. Subleading power corrections for N -jettiness subtractions

    Science.gov (United States)

    Moult, Ian; Rothen, Lorena; Stewart, Iain W.; Tackmann, Frank J.; Zhu, Hua Xing

    2017-04-01

    The N -jettiness observable TN provides a way of describing the leading singular behavior of the N -jet cross section in the τ =TN/Q →0 limit, where Q is a hard interaction scale. We consider subleading-power corrections in the τ ≪1 expansion, and employ soft-collinear effective theory to obtain analytic results for the dominant αsτ ln τ and αs2τ ln3τ subleading terms for thrust in e+e- collisions and 0-jettiness for q q ¯-initiated Drell-Yan-like processes at hadron colliders. These results can be used to significantly improve the numerical accuracy and stability of the N -jettiness subtraction technique for performing fixed-order calculations at next-to-leading order and next-to-next-to-leading order. They reduce the size of missing power corrections in the subtractions by an order of magnitude. We also point out that the precise definition of N -jettiness has an important impact on the size of the power corrections and thus the numerical accuracy of the subtractions. The sometimes employed definition of N -jettiness in the hadronic center-of-mass frame suffers from power corrections that grow exponentially with rapidity, causing the power expansion to deteriorate away from central rapidity. This degradation does not occur for the original N -jettiness definition, which explicitly accounts for the boost of the Born process relative to the frame of the hadronic collision, and has a well-behaved power expansion throughout the entire phase space. Integrated over rapidity, using this N -jettiness definition in the subtractions yields another order of magnitude improvement compared to employing the hadronic-frame definition.

  14. Moving object detection using background subtraction

    CERN Document Server

    Shaikh, Soharab Hossain; Chaki, Nabendu

    2014-01-01

    This Springer Brief presents a comprehensive survey of the existing methodologies of background subtraction methods. It presents a framework for quantitative performance evaluation of different approaches and summarizes the public databases available for research purposes. This well-known methodology has applications in moving object detection from video captured with a stationery camera, separating foreground and background objects and object classification and recognition. The authors identify common challenges faced by researchers including gradual or sudden illumination change, dynamic bac

  15. Digital mammography: state of the art.

    Science.gov (United States)

    Gater, Laura

    2002-01-01

    After completing this update on digital mammography, readers will: Understand some limitations of film-screen mammography. Know the potential advantages and disadvantages of digital mammography. Compare and contrast some different digital mammography systems. Describe how digital images are captured, processed, displayed and stored. Know how digital mammography affects radiation dose, exposure time and contrast resolution. Understand how digital images are transmitted. Be familiar with new techniques that build on digital mammography, such as 3-D mammography, digital subtraction mammography and computer-aided detection.

  16. Pain management in emergency department: intravenous morphine vs. intravenous acetaminophen

    Directory of Open Access Journals (Sweden)

    Morteza Talebi Doluee

    2015-01-01

    Full Text Available Pain is the most common complaint in emergency department and there are several methods for its control. Among them, pharmaceutical methods are the most effective. Although intravenous morphine has been the most common choice for several years, it has some adverse effects. There are many researches about intravenous acetaminophen as an analgesic agent and it appears that it has good analgesic effects for various types of pain. We searched some electronic resources for clinical trials comparing analgesic effects of intravenous acetaminophen vs. intravenous morphine for acute pain treatment in emergency setting.In two clinical trials, the analgesic effect of intravenous acetaminophen has been compared with intravenous morphine for renal colic. The results revealed no significant difference between analgesic effects of two medications. Another clinical trial revealed that intravenous acetaminophen has acceptable analgesic effects on the post-cesarean section pain when combined with other analgesic medications. One study revealed that administration of intravenous acetaminophen compared to placebo before hysterectomy decreased consumption of morphine via patient-controlled analgesia pump and decreased the side effects. Similarly, another study revealed that the infusion of intravenous acetaminophen vs. placebo after orthopedic surgery decreased the consumption of morphine after the surgery. A clinical trial revealed intravenous acetaminophen provided a level of analgesia comparable to intravenous morphine in isolated limb trauma, while causing less side effects than morphine.It appears that intravenous acetaminophen has good analgesic effects for visceral, traumatic and postoperative pains compare with intravenous morphine.

  17. A comparative study of additive and subtractive manufacturing for dental restorations.

    Science.gov (United States)

    Bae, Eun-Jeong; Jeong, Il-Do; Kim, Woong-Chul; Kim, Ji-Hwan

    2017-08-01

    Digital systems have recently found widespread application in the fabrication of dental restorations. For the clinical assessment of dental restorations fabricated digitally, it is necessary to evaluate their accuracy. However, studies of the accuracy of inlay restorations fabricated with additive manufacturing are lacking. The purpose of this in vitro study was to evaluate and compare the accuracy of inlay restorations fabricated by using recently introduced additive manufacturing with the accuracy of subtractive methods. The inlay (distal occlusal cavity) shape was fabricated using 3-dimensional image (reference data) software. Specimens were fabricated using 4 different methods (each n=10, total N=40), including 2 additive manufacturing methods, stereolithography apparatus and selective laser sintering; and 2 subtractive methods, wax and zirconia milling. Fabricated specimens were scanned using a dental scanner and then compared by overlapping reference data. The results were statistically analyzed using a 1-way analysis of variance (α=.05). Additionally, the surface morphology of 1 randomly (the first of each specimen) selected specimen from each group was evaluated using a digital microscope. The results of the overlap analysis of the dental restorations indicated that the root mean square (RMS) deviation observed in the restorations fabricated using the additive manufacturing methods were significantly different from those fabricated using the subtractive methods (Padditive manufacturing methods (P=.466). Similarly, no significant differences were found between wax and zirconia, the subtractive methods (P=.986). The observed RMS values were 106 μm for stereolithography apparatus, 113 μm for selective laser sintering, 116 μm for wax, and 119 μm for zirconia. Microscopic evaluation of the surface revealed a fine linear gap between the layers of restorations fabricated using stereolithography apparatus and a grooved hole with inconsistent weak scratches

  18. Digital radiology and ultrasound

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.

    1991-01-01

    With the access to digital methods for handling and processing images in general, many medical imaging methods are becoming more effectively handled digitally. This applies in particular to basically digital techniques such as CT and MR but also now includes Nuclear Medicine (NM), Ultrasound (US) and a variety of radiological procedures such as Digital Subtraction Angiography (DSA) and Fluoroscopy (DF). The access to conventional projection images by stimulatable plates (CR) or by digitization of film makes all of radiology potentially accessible, and the management of such images by a network is the basic aim of Picture Archiving and Communication Systems (PACS). However, it is suggested that in order for such systems to be of greater value, that way in which such images are treated needs to change, that is, digital images can be used to derive additional clinical value by appropriate processing

  19. NNLO jet cross sections by subtraction

    International Nuclear Information System (INIS)

    Somogyi, G.; Bolzoni, P.; Trocsanyi, Z.

    2010-06-01

    We report on the computation of a class of integrals that appear when integrating the so-called iterated singly-unresolved approximate cross section of an earlier NNLO subtraction scheme over the factorised phase space of unresolved partons. The integrated approximate cross section itself can be written as the product of an insertion operator (in colour space) times the Born cross section. We give selected results for the insertion operator for processes with two and three hard partons in the final state. (orig.)

  20. Computed tomography intravenous cholangiography

    International Nuclear Information System (INIS)

    Nascimento, S.; Murray, W.; Wilson, P.

    1997-01-01

    Indications for direct visualization of the bile ducts include bile duct dilatation demonstrated by ultrasound or computed tomography (CT) scanning, where the cause of the bile duct dilatation is uncertain or where the anatomy of bile duct obstruction needs further clarification. Another indication is right upper quadrant pain, particularly in a post-cholecystectomy patient, where choledocholithiasis is suspected. A possible new indication is pre-operative evaluation prior to laparoscopic cholecystectomy. The bile ducts are usually studied by endoscopic retrograde cholangiopancreatography (ERCP), or, less commonly, trans-hepatic cholangiography. The old technique of intravenous cholangiography has fallen into disrepute because of inconsistent bile-duct opacification. The advent of spiral CT scanning has renewed interest in intravenous cholangiography. The CT technique is very sensitive to the contrast agent in the bile ducts, and angiographic and three-dimensional reconstructions of the biliary tree can readily be obtained using the CT intravenous cholangiogram technique (CT IVC). Seven patients have been studied using this CT IVC technique, between February 1995 and June 1996, and are the subject of the present report. Eight further studies have since been performed. The results suggest that CT IVC could replace ERCP as the primary means of direct cholangiography, where pancreatic duct visualization is not required. (authors)

  1. Computed tomography intravenous cholangiography

    Energy Technology Data Exchange (ETDEWEB)

    Nascimento, S.; Murray, W.; Wilson, P. [Pittwater Radiology, Dee Why, NSW, (Australia)

    1997-08-01

    Indications for direct visualization of the bile ducts include bile duct dilatation demonstrated by ultrasound or computed tomography (CT) scanning, where the cause of the bile duct dilatation is uncertain or where the anatomy of bile duct obstruction needs further clarification. Another indication is right upper quadrant pain, particularly in a post-cholecystectomy patient, where choledocholithiasis is suspected. A possible new indication is pre-operative evaluation prior to laparoscopic cholecystectomy. The bile ducts are usually studied by endoscopic retrograde cholangiopancreatography (ERCP), or, less commonly, trans-hepatic cholangiography. The old technique of intravenous cholangiography has fallen into disrepute because of inconsistent bile-duct opacification. The advent of spiral CT scanning has renewed interest in intravenous cholangiography. The CT technique is very sensitive to the contrast agent in the bile ducts, and angiographic and three-dimensional reconstructions of the biliary tree can readily be obtained using the CT intravenous cholangiogram technique (CT IVC). Seven patients have been studied using this CT IVC technique, between February 1995 and June 1996, and are the subject of the present report. Eight further studies have since been performed. The results suggest that CT IVC could replace ERCP as the primary means of direct cholangiography, where pancreatic duct visualization is not required. (authors). 11 refs., 6 figs.

  2. Confirmation of T1-Bright Vein of Galen Aneurysm Spontaneous Thrombosis by Subtraction Magnetic Resonance Venography: A Case Report

    International Nuclear Information System (INIS)

    Irfan, M.; Lohman, B.; McKinney, A.M.

    2009-01-01

    Spontaneous thrombosis of a vein of Galen aneurysmal malformation (VOGM) is rare. We describe a 2-month-old patient with a patent VOGM and hydrocephalus, also confirmed patent at 6 months, but with subsequent lack of filling on pre-embolization catheter digital subtraction angiography (DSA) at 9 months' age. Due to the presence of T1- and T2-bright signal, noncontrast T1-weighted images (T1WI), T2-weighted images (T2WI), two-dimensional (2D) time-of-flight (TOF) magnetic resonance venography (MRV), and postcontrast T1WI were ambiguous for patency. However, subtracting the pre- from the postcontrast MRV images confirmed closure compared to subtracted images at 6 months' age. The factors contributing to thrombosis were likely a combination of a disproportionately small straight sinus, ventriculostomy, and contrast medium from DSA

  3. Confirmation of T1-Bright Vein of Galen Aneurysm Spontaneous Thrombosis by Subtraction Magnetic Resonance Venography: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Irfan, M.; Lohman, B.; McKinney, A.M. (Dept. of Radiology/Neuroradiology, Univ. of Minnesota, Minneapolis, Minnesota (United States))

    2009-08-15

    Spontaneous thrombosis of a vein of Galen aneurysmal malformation (VOGM) is rare. We describe a 2-month-old patient with a patent VOGM and hydrocephalus, also confirmed patent at 6 months, but with subsequent lack of filling on pre-embolization catheter digital subtraction angiography (DSA) at 9 months' age. Due to the presence of T1- and T2-bright signal, noncontrast T1-weighted images (T1WI), T2-weighted images (T2WI), two-dimensional (2D) time-of-flight (TOF) magnetic resonance venography (MRV), and postcontrast T1WI were ambiguous for patency. However, subtracting the pre- from the postcontrast MRV images confirmed closure compared to subtracted images at 6 months' age. The factors contributing to thrombosis were likely a combination of a disproportionately small straight sinus, ventriculostomy, and contrast medium from DSA.

  4. Parallel decompositions of Mueller matrices and polarimetric subtraction

    Directory of Open Access Journals (Sweden)

    Gil J.J.

    2010-06-01

    Full Text Available From a general formulation of the physically realizable parallel decompositions of the Mueller matrix M of a given depolarizing system, a procedure for determining the set of pure Mueller matrices susceptible to be subtracted from M is presented. This procedure provides a way to check if a given pure Mueller matrix N can be subtracted from M or not. If this check is positive, the value of the relative cross section of the subtracted component is also determined.

  5. Spectral amplitude coding OCDMA using and subtraction technique.

    Science.gov (United States)

    Hasoon, Feras N; Aljunid, S A; Samad, M D A; Abdullah, Mohamad Khazani; Shaari, Sahbudin

    2008-03-20

    An optical decoding technique is proposed for a spectral-amplitude-coding-optical code division multiple access, namely, the AND subtraction technique. The theory is being elaborated and experimental results have been done by comparing a double-weight code against the existing code, Hadamard. We have proved that the and subtraction technique gives better bit error rate performance than the conventional complementary subtraction technique against the received power level.

  6. Intravenous lidocaine infusion.

    Science.gov (United States)

    Soto, G; Naranjo González, M; Calero, F

    2018-02-26

    Systemic lidocaine used in continuous infusion during the peri-operative period has analgesic, anti-hyperalgesic, as well as anti-inflammatory properties. This makes it capable of reducing the use of opioids and inhalational anaesthetics, and the early return of bowel function, and patient hospital stay. The aim of this narrative review was to highlight the pharmacology and indications for clinical application, along with new and interesting research areas. The clinical applications of peri-operative lidocaine infusion have been reviewed in several recent systematic reviews and meta-analyses in patients undergoing open and laparoscopic abdominal procedures, ambulatory procedures, and other types of surgery. Peri-operative lidocaine infusion may be a useful analgesic adjunct in enhanced recovery protocols. Potential benefits of intravenous lidocaine in chronic post-surgical pain, post-operative cognitive dysfunction, and cancer recurrence are under investigation. Due to its immunomodulation properties over surgical stress, current evidence suggests that intravenous lidocaine could be used in the context of multimodal analgesia. Copyright © 2018 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Basic school pupils' strategies in solving subtraction problems ...

    African Journals Online (AJOL)

    This article reports some of the strategies basic schools children apply in solving subtraction problems. The purpose of the study was to see whether the semantic structure of mathematical problems influences children's choice of strategy in solving a subtraction problem. Mathematics Connection Vol. 4 2004: 31-37 ...

  8. Model Checking Timed Automata with Priorities using DBM Subtraction

    DEFF Research Database (Denmark)

    David, Alexandre; Larsen, Kim Guldstrand; Pettersson, Paul

    2006-01-01

    In this paper we describe an extension of timed automata with priorities, and efficient algorithms to compute subtraction on DBMs (difference bounded matrices), needed in symbolic model-checking of timed automata with priorities. The subtraction is one of the few operations on DBMs that result in...... this number affects the performance of symbolic model-checking. The uses of the DBM subtraction operation extend beyond timed automata with priorities. It is also useful for allowing guards on transitions with urgent actions, deadlock checking, and timed games.......In this paper we describe an extension of timed automata with priorities, and efficient algorithms to compute subtraction on DBMs (difference bounded matrices), needed in symbolic model-checking of timed automata with priorities. The subtraction is one of the few operations on DBMs that result...

  9. The Relationship Between Problem Size and Fixation Patterns During Addition, Subtraction, Multiplication, and Division

    Directory of Open Access Journals (Sweden)

    Evan T. Curtis

    2016-08-01

    Full Text Available Eye-tracking methods have only rarely been used to examine the online cognitive processing that occurs during mental arithmetic on simple arithmetic problems, that is, addition and multiplication problems with single-digit operands (e.g., operands 2 through 9; 2 + 3, 6 x 8 and the inverse subtraction and division problems (e.g., 5 – 3; 48 ÷ 6. Participants (N = 109 solved arithmetic problems from one of the four operations while their eye movements were recorded. We found three unique fixation patterns. During addition and multiplication, participants allocated half of their fixations to the operator and one-quarter to each operand, independent of problem size. The pattern was similar on small subtraction and division problems. However, on large subtraction problems, fixations were distributed approximately evenly across the three stimulus components. On large division problems, over half of the fixations occurred on the left operand, with the rest distributed between the operation sign and the right operand. We discuss the relations between these eye tracking patterns and other research on the differences in processing across arithmetic operations.

  10. [Construction of subtractive cDNA libraries of the sporogony stage of Eimeria tenella by suppression subtractive hybridization].

    Science.gov (United States)

    Han, Hong-Yu; Lin, Jiao-Jiao; Zhao, Qi-Ping; Dong, Hui; Jiang, Lian-Lian; Wang, Xin; Han, Jing-Fang; Huang, Bing

    2007-11-01

    In order to clone and identify differentially expressed genes in the sporogony stage of Eimeria tenella, the cDNAs from unsporulated oocysts and sporulated oocysts of E. tenella were used as driver, respectively, the cDNAs from sporozoites of E. tenella was used tester, Two subtractive cDNA libraries of sporozoites were constructed by using the technique of suppression subtractive hybridization (SSH). the cDNAs from unsporulated oocysts was used driver, the cDNAs from sporulated ooceysts was used tester, one subtractive cDNA library of sporulated oocysts was constructed. PCR amplification revealed that the two subtractive cDNA libraries of sporozoites and one subtractive cDNA library of sporulated oocysts contained approximated 96%, 96% and 98% recombinant clones, respectively. Fifty positive clones were sequenced and analyzed in GenBank with Blast search from three subtractive cDNA libraries, respectively, thirteen unique sequences were found from the subtractive cDNA library of sporulated oocysts, eight ESTs shared significant identity with previously described. A total of forty unique sequences were obtained from the two subtractive cDNA libraries, nine ESTs shared significant identity with previously described, the other sequences represent novel genes of E. tenella with no significant homology to the proteins in Genbank. These results have provided the foundation for cloning new genes of E. tenella and further studying new approaches to control coccidiosis.

  11. Intravenous fluids: balancing solutions.

    Science.gov (United States)

    Hoorn, Ewout J

    2017-08-01

    The topic of intravenous (IV) fluids may be regarded as "reverse nephrology", because nephrologists usually treat to remove fluids rather than to infuse them. However, because nephrology is deeply rooted in fluid, electrolyte, and acid-base balance, IV fluids belong in the realm of our specialty. The field of IV fluid therapy is in motion due to the increasing use of balanced crystalloids, partly fueled by the advent of new solutions. This review aims to capture these recent developments by critically evaluating the current evidence base. It will review both indications and complications of IV fluid therapy, including the characteristics of the currently available solutions. It will also cover the use of IV fluids in specific settings such as kidney transplantation and pediatrics. Finally, this review will address the pathogenesis of saline-induced hyperchloremic acidosis, its potential effect on outcomes, and the question if this should lead to a definitive switch to balanced solutions.

  12. Intravenous versus oral etoposide

    DEFF Research Database (Denmark)

    Ali, Abir Salwa; Grönberg, Malin; Langer, Seppo W.

    2018-01-01

    High-grade gastroenteropancreatic neuroendocrine neoplasms (GEP-NENs, G3) are aggressive cancers of the digestive system with poor prognosis and survival. Platinum-based chemotherapy (cisplatin/carboplatin + etoposide) is considered the first-line palliative treatment. Etoposide is frequently...... administered intravenously; however, oral etoposide may be used as an alternative. Concerns for oral etoposide include decreased bioavailability, inter- and intra-patient variability and patient compliance. We aimed to evaluate possible differences in progression-free survival (PFS) and overall survival (OS......) in patients treated with oral etoposide compared to etoposide given as infusion. Patients (n = 236) from the Nordic NEC study were divided into three groups receiving etoposide as a long infusion (24 h, n = 170), short infusion (≤ 5 h, n = 33) or oral etoposide (n = 33) according to hospital tradition. PFS...

  13. Usefulness of multi-plane dynamic subtraction CT (MPDS-CT) for intracranial high density lesions

    International Nuclear Information System (INIS)

    Takagi, Ryo; Kumazaki, Tatsuo

    1996-01-01

    We present a new CT technique using the high speed CT scanner in detection and evaluation of temporal and spatial contrast enhancement of intracranial high density lesions. A multi-plane dynamic subtraction CT (MPDS-CT) was performed in 21 patients with intracranial high density lesions. These lesions consisted of 10 brain tumors, 7 intracerebral hemorrhages and 4 vascular malformations (2 untreated, 2 post-embolization). Baseline study was first performed, and 5 sequential planes of covering total high density lesions were selected. After obtaining the 5 sequential CT images as mask images, three series of multi-plane dynamic CT were performed for the same 5 planes with an intravenous bolus injection of contrast medium. MPDS-CT images were reconstructed by subtracting dynamic CT images from the mask ones. MPDS-CT were compared with conventional contrast-enhanced CT. MPDS-CT images showed the definite contrast enhancement of high density brain tumors and vascular malformations which were not clearly identified on conventional contrast-enhanced CT images because of calcified or hemorrhagic lesions and embolic materials, enabling us to eliminate enhanced abnormalities with non-enhanced areas such as unusual intracerebral hemorrhages. MPDS-CT will provide us further accurate and objective information and will be greatly helpful for interpreting pathophysiologic condition. (author)

  14. Quantitative analysis of alveolar bone change following implant placement using intraoral radiographic subtraction

    International Nuclear Information System (INIS)

    Kimura, Hiroyuki; Kanda, Shigenobu; Tanaka, Takemasa

    2002-01-01

    The purpose of this study was to develop a procedure for quantitative analysis using intraoral radiographs of alveolar bone after placement of dental implants and to consider the validity of the method. We evaluated the ten patients (2 males and 8 females, average age: 48.4 years-old), who were treated with dental implant operation in the site of mandibular molar region, since October of 1999 until September of 2000 in Kimura Dental Clinic (Kumamoto, Japan). We evaluated the intraoral radiographs taken pre- and post- operatively and at follow-up examination. To detect alveolar bone change on radiograph, we adopted the digital subtraction method. Although the radiographs were taken under an ordinary technique with cone indicator, we did not apply the standardized technique with fixing material customized for each patient. Therefore, we used geometric correction and density compensation before subtraction. We assessed the basic statistical values (mean, variance, kurtosis and skewness) of the region of interest (ROI) of the subtracted images. Also, we noted PPD (probing pocket depth) and BOP (bleeding on probing) at each site as indicators of clinical findings and all implanted sites were classified according to the PPD or BOP, i.e. PPD increased group ''PPD (+)'' and PPD stable group ''PPD (-)'', likewise BOP positive group ''BOP (+)'' and negative group ''BOP (-)''. We considered the statistical values of ROI in each group and compared these findings. Mean and variance values of PPD (+) were higher than those of PPD (-) and there was a significant difference in mean value (p=0.031). Similarly, mean and variance values of BOP (+) were statistically higher than those of BOP (-) (p=0.041 and p=0.0087, respectively). Concerning kurtosis and skewness, there was no difference between PPD (+) and PPD (-), or between BOP (+) and BOP (-). Using our method, the radiographs taken for follow-up examination could be assessed quantitatively. It is suggested that geometric

  15. Digital imaging primer

    CERN Document Server

    Parkin, Alan

    2016-01-01

    Digital Imaging targets everyyone with an interest in digital imaging, be they professional or private, who uses even quite modest equipment such as a PC, digital camera and scanner, a graphics editor such as Paint, and an inkjet printer. Uniquely, it is intended to fill the gap between highly technical texts for academics (with access to expensive equipment) and superficial introductions for amateurs. The four-part treatment spans theory, technology, programs and practice. Theory covers integer arithmetic, additive and subtractive color, greyscales, computational geometry, and a new presentation of discrete Fourier analysis; Technology considers bitmap file structures, scanners, digital cameras, graphic editors, and inkjet printers; Programs develops several processing tools for use in conjunction with a standard Paint graphics editor and supplementary processing tools; Practice discusses 1-bit, greyscale, 4-bit, 8-bit, and 24-bit images for the practice section. Relevant QBASIC code is supplied an accompa...

  16. Accessing the diffracted wavefield by coherent subtraction

    Science.gov (United States)

    Schwarz, Benjamin; Gajewski, Dirk

    2017-10-01

    Diffractions have unique properties which are still rarely exploited in common practice. Aside from containing subwavelength information on the scattering geometry or indicating small-scale structural complexity, they provide superior illumination compared to reflections. While diffraction occurs arguably on all scales and in most realistic media, the respective signatures typically have low amplitudes and are likely to be masked by more prominent wavefield components. It has been widely observed that automated stacking acts as a directional filter favouring the most coherent arrivals. In contrast to other works, which commonly aim at steering the summation operator towards fainter contributions, we utilize this directional selection to coherently approximate the most dominant arrivals and subtract them from the data. Supported by additional filter functions which can be derived from wave front attributes gained during the stacking procedure, this strategy allows for a fully data-driven recovery of faint diffractions and makes them accessible for further processing. A complex single-channel field data example recorded in the Aegean sea near Santorini illustrates that the diffracted background wavefield is surprisingly rich and despite the absence of a high channel count can still be detected and characterized, suggesting a variety of applications in industry and academia.

  17. Digital cineangiography using parallel transfer disk in neuroradiology

    International Nuclear Information System (INIS)

    Purdy, P.D.; Murray, R.C. Jr.

    1986-01-01

    Using parallel transfer disk technology, digitally subtracted images now can be acquired for immediate review at rates up to 30 frames per second. The authors have performed 5 studies on 50 patients using 30 frame per second digital acquisition. Imaged were eight carotid-cavernous fistulas, three aneurysms, 21 arteriovenous malformations, 11 cases of stroke or transient ischemic attack, and eight miscellaneous conditions. When compared with plain film acquisitions at two exposures per second, the digital study gave additional diagnostic information in 32 cases. The increased frame storage capacity and the availability of immediate subtraction with digital cineangiography represent a significant advance in the evaluation of flow dynamics in diagnostic and therapeutic neuranogiography

  18. Purification of photon subtraction from continuous squeezed light by filtering

    Science.gov (United States)

    Yoshikawa, Jun-ichi; Asavanant, Warit; Furusawa, Akira

    2017-11-01

    Photon subtraction from squeezed states is a powerful scheme to create good approximation of so-called Schrödinger cat states. However, conventional continuous-wave-based methods actually involve some impurity in squeezing of localized wave packets, even in the ideal case of no optical losses. Here, we theoretically discuss this impurity by introducing mode match of squeezing. Furthermore, here we propose a method to remove this impurity by filtering the photon-subtraction field. Our method in principle enables creation of pure photon-subtracted squeezed states, which was not possible with conventional methods.

  19. Dual-tracer background subtraction approach for fluorescent molecular tomography

    Science.gov (United States)

    Holt, Robert W.; El-Ghussein, Fadi; Davis, Scott C.; Samkoe, Kimberley S.; Gunn, Jason R.; Leblond, Frederic

    2013-01-01

    Abstract. Diffuse fluorescence tomography requires high contrast-to-background ratios to accurately reconstruct inclusions of interest. This is a problem when imaging the uptake of fluorescently labeled molecularly targeted tracers in tissue, which can result in high levels of heterogeneously distributed background uptake. We present a dual-tracer background subtraction approach, wherein signal from the uptake of an untargeted tracer is subtracted from targeted tracer signal prior to image reconstruction, resulting in maps of targeted tracer binding. The approach is demonstrated in simulations, a phantom study, and in a mouse glioma imaging study, demonstrating substantial improvement over conventional and homogenous background subtraction image reconstruction approaches. PMID:23292612

  20. Ultrasonography versus intravenous urography

    International Nuclear Information System (INIS)

    Aslaksen, A.

    1991-01-01

    The present study was performed to compare the clinical value of urography and ultrasonography in a non-selected group of patients referred for urography to a university hospital. The conslusions and clinical implications of the study are as follows: Intravenous urography remains the cornerstone imaging examination in the evaluation of ureteral calculi. Ultrasonography is a valuable adjunct in cases of non- visualization of the kidneys, in distal obstruction and known contrast media allergy. When women with recurrent urinary tract infection are referred for imaging of the urinary tract, ultrasonography should be used. Ultrasonography should replace urography for screening of non-acute hydronephrosis like in female genital cancer and benign prostate hyperplasia. There is good correlation between urography and ultrasonography in assessing the degree of hydronephrosis. However, more researh on the relationship between hydronephrosis and obstruction is necessary. Ultrasonography should be used as the only imaging method of the upper urinary tract in patients with microscopic hematuria. In patients less than 50 years with macroscopic hematuria, ultrasonography should be used as the only imaging of the upper urinary tract, and an examination of the urinary bladder should be included. In patients over 50 years, urography supplied with ultrasonography should be used, but more research is necessary on the subject of imaging method and age. 158 refs

  1. Digital fluorographic method and system

    International Nuclear Information System (INIS)

    Ledley, R.S.

    1985-01-01

    This invention relates to a digital fluorographic method and system, in particular a method and system which calls for the digitization and storage of first and second x-ray picture data derived before and after injection of a contrast medium into a subject. The digitized pictures are stored in separate memories in an associated system, and can be separately whole-picture processed to develop corresponding processed picture data. The resulting data are subtractively combined to produce data corresponding to a pictorial representation of differences between the x-ray picture before and after injection of the contrast medium

  2. Identification of differential genes by suppression subtractive hybridization: I. Preparation of subtracted cDNA or genomic DNA library.

    Science.gov (United States)

    Rebrikov, Denis V

    2008-07-01

    INTRODUCTIONSuppression subtractive hybridization (SSH) is one of the most powerful and popular methods for generating subtracted cDNA or genomic DNA libraries. This technique can be used to compare two mRNA populations and obtain cDNAs representing genes that are either overexpressed or exclusively expressed in one population as compared to another. It can also be used for comparison of genomic DNA populations. This protocol describes the preparation of a subtracted cDNA or genomic DNA library, and includes methods for cDNA synthesis, tester and driver DNA digestion, and adapter ligation.

  3. Digital fluoroscopy: a new development in medical imaging

    International Nuclear Information System (INIS)

    Maher, K.P.; Malone, J.F.; Dublin Inst. of Technology

    1986-01-01

    Medical fluoroscopy is briefly reviewed and video-image digitization is described. Image processing requirements and image processors available for digital fluoroscopy are discussed in detail. Specific reference is made to an application of digital fluoroscopy in the imaging of blood-vessels. This application involves an image substraction technique which is referred to as digital subtraction angiography (DSA). A number of DSA images of relevance to the discussion are included. (author)

  4. DSA in digital replantations

    International Nuclear Information System (INIS)

    Wang Liuhong; Chao Ming; Jiang Dingyao; Zhang Guangqiang; Wu Jianjun; Chen Xianyi; Li Bin; Sun Jihong

    2008-01-01

    Objective: To assess revascularization and vessel anastomosis in digital replantations with DSA. Methods: Twelve cases of digital replantations underwent digital subtract angiography during 2 to 4 days after fingers reattachment. The vessel anastomosis, hemodynamics, stenosis and discontinuation were investigated. The unobstructed and smooth anastomosis was suggested as early stage survival of the reattached fingers, the spasm and stenosis of the reattached vessels were considered as mild vascular crisis, and the discontinuation of hemodynamics were indicated as severe vascular crisis. Results: The total 27 vessels were clearly displayed on DSA. Of these vessels, 23 vessels were unobstructed and smooth, all digits were survived. Diagnosis coincidence of early stage survival was 100% (23/23). Two vessels were obstructed, which were testified having thrombus by operation research. The other 2 vessels were spasm, the digits were also survived ultimately by expectant treatment. All 4 abnormal vessel anatomosis were found by DSA. Conclusion: DSA is important modality in assessing revascularization and blood circulation for digital replantations, guiding in dealing with the vascular crisis, and in predicting early stage survival of the reattached digits. (authors)

  5. Ictal cerebral perfusion patterns in partial epilepsy: SPECT subtraction

    International Nuclear Information System (INIS)

    Lee, Hyang Woon; Hong, Seung Bong; Tae, Woo Suk; Kim, Sang Eun; Seo, Dae Won; Jeong, Seung Cheol; Yi, Ji Young; Hong, Seung Chyul

    2000-01-01

    To investigate the various ictal perfusion patterns and find the relationships between clinical factors and different perfusion patterns. Interictal and ictal SPECT and SPECT subtraction were performed in 61 patients with partial epilepsy. Both positive images showing ictal hyperperfusion and negative images revealing ictal hypoperfusion were obtained by SPECT subtraction. The ictal perfusion patterns of subtracted SPECT were classified into focal hyperperfusion, hyperperfusion-plus, combined hyperperfusion-hypoperfusion, and focal hypoperfusion only. The concordance rates with epileptic focus were 91.8% in combined analysis of ictal hyperperfusion and hypoperfusion images of subtracted SPECT, 85.2% in hyperperfusion images only of subtracted SPECT, and 68.9% in conventional ictal SPECT analysis. Ictal hypoperfusion occurred less frequently in temporal lobe epilepsy (TLE) than extratemporal lobe epilepsy. Mesial temporal hyperperfusion alone was seen only in mesial TLE while lateral temporal hyperperfusion alone was observed only in neocortical TLE. Hippocampal sclerosis had much lower incidence of ictal hypoperfusion than any other pathology. Some patients showed ictal hypoperfusion at epileptic focus with ictal hyperperfusion in the neighboring brain regions where ictal discharges propagated. Hypoperfusion as well as hyperperfusion in ictal SPECT should be considered for localizing epileptic focus. Although the mechanism of ictal hypoperfusion could be an intra-ictal early exhaustion of seizure focus or a steal phenomenon by the propagation of ictal discharges to adjacent brain areas, further study is needed to elucidate it.=20

  6. Intravenous pyogenic granuloma or intravenous lobular capillary hemangioma

    Energy Technology Data Exchange (ETDEWEB)

    Ghekiere, Olivier; Galant, Christine; Berg, Bruno Vande [Cliniques Universitaires St. Luc, Department of Radiology, Brussels (Belgium)

    2005-06-01

    Lobular capillary hemangioma is a vascular neoplasm that commonly occurs as a cutaneous tumor. When it involves the skin and mucosal surfaces, ulceration and suppuration may occur, hence the classic term of pyogenic granuloma. Intravenous pyogenic granuloma is a rare solitary form of lobular capillary hemangioma that usually occurs in the veins of the neck and upper extremities. We report the ultrasonographic and magnetic resonance imaging findings of a pyogenic intravenous granuloma localized in the right cephalic vein. The imaging and pathological findings and the differential diagnoses are discussed. (orig.)

  7. Orthostatic stability with intravenous levodopa

    Directory of Open Access Journals (Sweden)

    Shan H. Siddiqi

    2015-08-01

    Full Text Available Intravenous levodopa has been used in a multitude of research studies due to its more predictable pharmacokinetics compared to the oral form, which is used frequently as a treatment for Parkinson’s disease (PD. Levodopa is the precursor for dopamine, and intravenous dopamine would strongly affect vascular tone, but peripheral decarboxylase inhibitors are intended to block such effects. Pulse and blood pressure, with orthostatic changes, were recorded before and after intravenous levodopa or placebo—after oral carbidopa—in 13 adults with a chronic tic disorder and 16 tic-free adult control subjects. Levodopa caused no statistically or clinically significant changes in blood pressure or pulse. These data add to previous data that support the safety of i.v. levodopa when given with adequate peripheral inhibition of DOPA decarboxylase.

  8. Bi-Event Subtraction Technique at hadron colliders

    International Nuclear Information System (INIS)

    Dutta, Bhaskar; Kamon, Teruki; Kolev, Nikolay; Krislock, Abram

    2011-01-01

    We propose the Bi-Event Subtraction Technique (BEST) as a method of modeling and subtracting large portions of the combinatoric background during reconstruction of particle decay chains at hadron colliders. The combinatoric background arises when it is impossible to know experimentally which observed particles come from the decay chain of interest. The background shape can be modeled by combining observed particles from different collision events and be subtracted away, greatly reducing the overall background. This idea has been demonstrated in various experiments in the past. We generalize it by showing how to apply BEST multiple times in a row to fully reconstruct a cascade decay. We show the power of BEST with two simulated examples of its application towards reconstruction of the top quark and a supersymmetric decay chain at the Large Hadron Collider.

  9. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    International Nuclear Information System (INIS)

    Altaha, Mustafa A.; Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J.; Rick, Manuela; Schmitt, Peter; Wintersperger, Bernd J.

    2017-01-01

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm 2 ) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm 3 ) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  10. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Altaha, Mustafa A. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Rick, Manuela; Schmitt, Peter [Siemens Healthcare, Erlangen (Germany); Wintersperger, Bernd J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Toronto General Hospital, Department of Medical Imaging, Toronto, Ontario (Canada)

    2017-03-15

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm{sup 2}) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm{sup 3}) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  11. Use of signal subtraction methods in ESR dating of burned flint

    International Nuclear Information System (INIS)

    Porat, Naomi; Schwarcz, H.P.

    1991-01-01

    Geological samples of chert display some of the characteristics of electron spin resonance (ESR) signals of quartz. When chert is heated in a fireplace, most of these signals are annealed. The signals grow again in fire-heated chert buried in archaeological sites, as a result of internal and external radiation doses. The date of the heating event can be determined from the acquired dose (AD) and the dose rate. The E' and Al signals are best suited for dating. Although many cherts, when heated to a sufficient temperature, acquire a carbon radical (C) signal that largely obscures the E' signal, it can be subtracted from digitized spectra. The E' signal also appears to saturate at relatively low doses, restricting the time range of dating to between 200 and 600 ka, depending on the dose rates. The Al signal shows no saturation, but is also interfered with by organic signals, present in burnt and unburned flint. These can also be subtracted to reveal the ''pure'' Al signal. Applying the E' signal to date flint from Yabroud, we obtain an age between 100 and 125 ka, while both thermoluminescence (TL) dating of the flint and ESR dating of tooth enamel give 195 and 225 ka, respectively; the discrepancy may be due to an overestimate of the α-efficiency. At Nahr Ibrahim, the age (c. 80 ka) is consistent with archaeological estimates. (author)

  12. Subtraction radiography and computer assisted densitometric analyses of standardized radiographs

    International Nuclear Information System (INIS)

    Ortmann, L.F.; Dunford, R.; McHenry, K.; Hausmann, E.

    1985-01-01

    A standardized radiographic series of incrementally increasing alveolar crestal defects in skulls were subjected to analyses by subtraction radiography and computer assisted quantitative densitometric analysis. Subjects were able to detect change using subtraction radiography in alveolar bone defects with bone loss in the range of 1-5 percent as measured by 125 I absorptiometry. Quantitative densitometric analyses utilizing radiographic pairs adjusted for differences in contrast (gamma corrected) can be used to follow longitudinal changes at a particular alveolar bone site. Such measurements correlate with change observed by 125 I absorptiometry (r=0.82-0.94). (author)

  13. Usefulness of dynamic subtraction CT for intracranial high density lesions

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ryo; Hayashi, Hiromitsu; Ichikawa, Taro; Kumazaki, Tatsuo (Nippon Medical School, Tokyo (Japan))

    1994-04-01

    Dynamic subtraction CT (DSCT) using a high speed Rotate/Rotate CT Scanner (Toshiba Xforce) was performed on 10 patients with intracranial high density lesions such as brain tumors and vascular malformations. In comparison with conventional contrast enhanced CT, the technique of dynamic subtraction CT enabled us to evaluate more clearly the contrast enhancement of high density lesions and to separate more easily the lesions from hematoma and calcification, which are shown as avascular areas. The results suggest that DSCT is a valuable method for evaluating the contrast enhancement of intracranial high density lesions. (author).

  14. Multi-slice CT for visualization of acute pulmonary embolism: single breath-hold subtraction technique

    Energy Technology Data Exchange (ETDEWEB)

    Wildberger, J.E.; Mahnken, A.H.; Spuentrup, E.; Guenther, R.W. [Dept. of Diagnostic Radiology, Univ. of Technology, Aachen (Germany); Klotz, E.; Ditt, H. [Siemens Medical Solutions, Computed Tomography, Forchheim (Germany)

    2005-01-01

    Purpose: the purpose of our preliminary animal study was to evaluate the feasibility of a new subtraction technique for visualization of perfusion defects within the lung parenchyma in segmental and subsegmental pulmonary embolism (PE). Materials and methods: in three healthy pigs, PE were artificially induced by fresh human clot material. Within a single breath-hold, CT angiography (CTA) was performed on a 16-slice multi-slice CT scanner (SOMATOM Sensation 16; Siemens, Forchheim, Germany) before and after intravenous application of 80 mL of contrast-medium, followed by a saline chaser. Scan parameters were 120 kV and 100 mAs{sub eff.}, using a collimation of 16 x 1.5 mm and a table speed/rot. of 36 mm (pitch: 1.5; rotation time: 0.5 s). A new 3D subtraction technique was developed, which is based on automated segmentation, non-linear spatial filtering and non-rigid registration. Data were analysed using a color-encoded ''compound view'' of parenchymal enhancement and CTA information displayed in axial, coronal and sagittal orientation. Results: subtraction was technically feasible in all three data sets. The mean scan time for each series was 4.7 s, interscan delay was 14.7 s, respectively. Therefore, an average breath-hold of approximately 24 s was required for the overall scanning procedure. Downstream of occluded segmental and subsegmental arteries, perfusion defects were clearly assessable, showing lower or missing enhancement compared to normally perfused lung parenchyma. In all pigs, additional peripheral areas with triangular shaped perfusion defects were delineated, considered typical for PE. Conclusions: our initial results from the animal model studied slow that perfusion imaging of PE is feasible within a single breath-hold. It allows a comprehensive assessment of perfusion deficits as the direct proof of a pulmonary embolus, can be combined with an indirect visual quantification of the density changes in the adjacent lung tissue

  15. Intravenous urography and childhood trauma

    OpenAIRE

    Okorie, N. M.; MacKinnon, A. E.

    1982-01-01

    Results of intravenous urography (IVU) in 33 patients suspected of suffering from renal trauma were reviewed. It was concluded that when haematuria is only detected microscopically and clears within 24 hr then an IVU is not necessary, in the absence of other evidence of significant urinary tract injury.

  16. Real-time digital angiocardiography using a temporal high-pass filter

    International Nuclear Information System (INIS)

    Hardin, C.W.; Kruger, R.A.; Anderson, F.L.; Bray, B.F.; Nelson, J.A.

    1984-01-01

    A temporal high-pass filtration technique for digital subtraction angiocardiography was studied, using real-time digital studies performed simultaneously with routine cineangiocardiography (cine) for qualitative image comparison. The digital studies showed increased contrast and suppression of background anatomy and also enhanced detection of wall motion abnormalities when compared with cine. The digital images are comparable with, and in some cases better than, cine images. Clinical efficacy of this digital technique is currently being evaluated

  17. Intravenous volume tomographic pulmonary angiography imaging

    Science.gov (United States)

    Ning, Ruola; Strang, John G.; Chen, Biao; Conover, David L.; Yu, Rongfeng

    1999-05-01

    This study presents a new intravenous (IV) tomographic angiography imaging technique, called intravenous volume tomographic digital angiography (VTDA) for cross sectional pulmonary angiography. While the advantages of IV-VTDA over spiral CT in terms of volume scanning time and resolution have been validated and reported in our previous papers for head and neck vascular imaging, the superiority of IV-VTDA over spiral CT for cross sectional pulmonary angiography has not been explored yet. The purpose of this study is to demonstrate the advantage of isotropic resolution of IV-VTDA in the x, y and z directions through phantom and animal studies, and to explore its clinical application for detecting clots in pulmonary angiography. A prototype image intensifier-based VTDA imaging system has been designed and constructed by modifying a GE 8800 CT scanner. This system was used for a series of phantom and dog studies. A pulmonary vascular phantom was designed and constructed. The phantom was scanned using the prototype VTDA system for direct 3D reconstruction. Then the same phantom was scanned using a GE CT/i spiral CT scanner using the routine pulmonary CT angiography protocols. IV contrast injection and volume scanning protocols were developed during the dog studies. Both VTDA reconstructed images and spiral CT images of the specially designed phantom were analyzed and compared. The detectability of simulated vessels and clots was assessed as the function of iodine concentration levels, oriented angles, and diameters of the vessels and clots. A set of 3D VTDA reconstruction images of dog pulmonary arteries was obtained with different IV injection rates and isotropic resolution in the x, y and z directions. The results of clot detection studies in dog pulmonary arteries have also been shown. This study presents a new tomographic IV angiography imaging technique for cross sectional pulmonary angiography. The results of phantom and animal studies indicate that IV-VTDA is

  18. Addition and Subtraction by Students with Down Syndrome

    Science.gov (United States)

    Herrera, Aurelia Noda; Bruno, Alicia; Gonzalez, Carina; Moreno, Lorenzo; Sanabria, Hilda

    2011-01-01

    We present a research report on addition and subtraction conducted with Down syndrome students between the ages of 12 and 31. We interviewed a group of students with Down syndrome who executed algorithms and solved problems using specific materials and paper and pencil. The results show that students with Down syndrome progress through the same…

  19. Novel Ratio Subtraction and Isoabsorptive Point Methods for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate two innovative spectrophotometric methods used for the simultaneous determination of ambroxol hydrochloride and doxycycline in their binary mixture. Methods: Ratio subtraction and isoabsorptive point methods were used for the simultaneous determination of ambroxol hydrochloride ...

  20. Identifying quantumness via addition-then-subtraction operation

    OpenAIRE

    Lee, Su-Yong; Noh, Changsuk; Kaszlikowski, Dagomir

    2012-01-01

    We propose a measure of quantumness based on an addition-then-subtraction operation. We demonstrate how this measure can distinguish between classical and bosonic particles by investigating in detail multi-particle bosonic systems. Experimental schemes implementing this measure for bosons in all-optical and atom-cavity systems are provided. We also apply this measure to single-mode fermionic systems.

  1. "Abuelita" Epistemologies: Counteracting Subtractive Schools in American Education

    Science.gov (United States)

    Gonzales, Sandra M.

    2015-01-01

    This autoethnographic inquiry examines the intersection of elder epistemology and subtractive education, exploring how one "abuelita" countered her granddaughter's divestment of Mexican-ness. I demonstrate how the grandmother used "abuelita" epistemologies to navigate this tension and resist the assimilative pressures felt…

  2. Subtraction-noise projection in gravitational-wave detector networks

    Science.gov (United States)

    Harms, Jan; Mahrdt, Christoph; Otto, Markus; Prieß, Malte

    2008-06-01

    In this paper, we present a successful implementation of a subtraction-noise projection method into a simple, simulated data analysis pipeline of a gravitational-wave search. We investigate the problem to reveal a weak stochastic background signal which is covered by a strong foreground of compact-binary coalescences. The foreground, which is estimated by matched filters, has to be subtracted from the data. Even an optimal analysis of foreground signals will leave subtraction noise due to estimation errors of template parameters which may corrupt the measurement of the background signal. The subtraction noise can be removed by a noise projection. We apply our analysis pipeline to the proposed future-generation space-borne Big Bang Observer mission which seeks for a stochastic background of primordial gravitational waves in the frequency range ˜0.1Hz—1Hz covered by a foreground of black-hole and neutron-star binaries. Our analysis is based on a simulation code which provides a dynamical model of a time-delay interferometer network. It generates the data as time series and incorporates the analysis pipeline together with the noise projection. Our results confirm previous ad hoc predictions which say that the Big Bang Observer will be sensitive to backgrounds with fractional energy densities below Ω=10-16.

  3. Digital broadcasting

    International Nuclear Information System (INIS)

    Park, Ji Hyeong

    1999-06-01

    This book contains twelve chapters, which deals with digitization of broadcast signal such as digital open, digitization of video signal and sound signal digitization of broadcasting equipment like DTPP and digital VTR, digitization of equipment to transmit such as digital STL, digital FPU and digital SNG, digitization of transmit about digital TV transmit and radio transmit, digital broadcasting system on necessity and advantage, digital broadcasting system abroad and Korea, digital broadcasting of outline, advantage of digital TV, ripple effect of digital broadcasting and consideration of digital broadcasting, ground wave digital broadcasting of DVB-T in Europe DTV in U.S.A and ISDB-T in Japan, HDTV broadcasting, satellite broadcasting, digital TV broadcasting in Korea, digital radio broadcasting and new broadcasting service.

  4. A method for dynamic subtraction MR imaging of the liver

    Directory of Open Access Journals (Sweden)

    Setti Ernesto

    2006-06-01

    Full Text Available Abstract Background Subtraction of Dynamic Contrast-Enhanced 3D Magnetic Resonance (DCE-MR volumes can result in images that depict and accurately characterize a variety of liver lesions. However, the diagnostic utility of subtraction images depends on the extent of co-registration between non-enhanced and enhanced volumes. Movement of liver structures during acquisition must be corrected prior to subtraction. Currently available methods are computer intensive. We report a new method for the dynamic subtraction of MR liver images that does not require excessive computer time. Methods Nineteen consecutive patients (median age 45 years; range 37–67 were evaluated by VIBE T1-weighted sequences (TR 5.2 ms, TE 2.6 ms, flip angle 20°, slice thickness 1.5 mm acquired before and 45s after contrast injection. Acquisition parameters were optimized for best portal system enhancement. Pre and post-contrast liver volumes were realigned using our 3D registration method which combines: (a rigid 3D translation using maximization of normalized mutual information (NMI, and (b fast 2D non-rigid registration which employs a complex discrete wavelet transform algorithm to maximize pixel phase correlation and perform multiresolution analysis. Registration performance was assessed quantitatively by NMI. Results The new registration procedure was able to realign liver structures in all 19 patients. NMI increased by about 8% after rigid registration (native vs. rigid registration 0.073 ± 0.031 vs. 0.078 ± 0.031, n.s., paired t-test and by a further 23% (0.096 ± 0.035 vs. 0.078 ± 0.031, p t-test after non-rigid realignment. The overall average NMI increase was 31%. Conclusion This new method for realigning dynamic contrast-enhanced 3D MR volumes of liver leads to subtraction images that enhance diagnostic possibilities for liver lesions.

  5. Intravenous Antiepileptic Drugs in Russia

    Directory of Open Access Journals (Sweden)

    P. N. Vlasov

    2014-01-01

    Full Text Available Launching four intravenous antiepileptic drugs: valproate (Depakene and Convulex, lacosamide (Vimpat, and levetiracetam (Keppra – into the Russian market has significantly broadened the possibilities of rendering care to patients in seizure emergency situations. The chemi- cal structure, mechanisms of action, indications/contraindications, clinical effectiveness and tolerability, advantages/disadvantages, and adverse events of using these drugs in urgent and elective neurology are discussed. 

  6. Muscle power during intravenous sedation

    Directory of Open Access Journals (Sweden)

    Nobuyuki Matsuura

    2017-11-01

    Full Text Available Intravenous sedation is effective to reduce fear and anxiety in dental treatment. It also has been used for behavior modification technique in dental patients with special needs. Midazolam and propofol are commonly used for intravenous sedation. Although there have been many researches on the effects of midazolam and propofol on vital function and the recovery profile, little is known about muscle power. This review discusses the effects of intravenous sedation using midazolam and propofol on both grip strength and bite force. During light propofol sedation, grip strength increases slightly and bite force increases in a dose-dependent manner. Grip strength decreases while bite force increases during light midazolam sedation, and also during light sedation using a combination of midazolam and propofol. Flumazenil did not antagonise the increase in bite force by midazolam. These results may suggest following possibilities; (1 Activation of peripheral benzodiazepine receptors located within the temporomandibular joint region and masticatory muscles may be the cause of increasing bite force. (2 Propofol limited the long-latency exteroceptive suppression (ES2 period during jaw-opening reflex. Thus, control of masticatory muscle contraction, which is thought to have a negative feedback effect on excessive bite force, may be depressed by propofol.

  7. Number Words in Young Children's Conceptual and Procedural Knowledge of Addition, Subtraction and Inversion

    Science.gov (United States)

    Canobi, Katherine H.; Bethune, Narelle E.

    2008-01-01

    Three studies addressed children's arithmetic. First, 50 3- to 5-year-olds judged physical demonstrations of addition, subtraction and inversion, with and without number words. Second, 20 3- to 4-year-olds made equivalence judgments of additions and subtractions. Third, 60 4- to 6-year-olds solved addition, subtraction and inversion problems that…

  8. Multivariate spatial condition mapping using subtractive fuzzy cluster means.

    Science.gov (United States)

    Sabit, Hakilo; Al-Anbuky, Adnan

    2014-10-13

    Wireless sensor networks are usually deployed for monitoring given physical phenomena taking place in a specific space and over a specific duration of time. The spatio-temporal distribution of these phenomena often correlates to certain physical events. To appropriately characterise these events-phenomena relationships over a given space for a given time frame, we require continuous monitoring of the conditions. WSNs are perfectly suited for these tasks, due to their inherent robustness. This paper presents a subtractive fuzzy cluster means algorithm and its application in data stream mining for wireless sensor systems over a cloud-computing-like architecture, which we call sensor cloud data stream mining. Benchmarking on standard mining algorithms, the k-means and the FCM algorithms, we have demonstrated that the subtractive fuzzy cluster means model can perform high quality distributed data stream mining tasks comparable to centralised data stream mining.

  9. Subtraction imaging of the ECG gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Tanegashima, K.; Fukui, M.; Hyodo, H.

    1987-05-01

    The subtracting manipulation of contrast-enhanced gated cardiac CT (GCCT) images was experimentally studied with TCT 60A - 30 type (Toshiba) for clinical use, thereby reducing the amount of contrast medium (CM). Initially the optimum relationship between the concentration of CM and its injected velocity was determined using the model of resected canine hearts and in actual dogs. The emphasized good-subtracted images were obtained when the difference of CT values was approximately 40 H.U. between cardiac cavity and myocardium. Such condition was feasible in the use of 25 % Diatrizoic acid and its injected velocity of 0.02 ml/kg/sec. Finally the reduction of the amount of CM by 1/3 became possible in clinical settings. The method is applicable to multi-slice GCCT in various heart diseases.

  10. Momentum-subtraction renormalization techniques in curved space-time

    Energy Technology Data Exchange (ETDEWEB)

    Foda, O.

    1987-10-01

    Momentum-subtraction techniques, specifically BPHZ and Zimmermann's Normal Product algorithm, are introduced as useful tools in the study of quantum field theories in the presence of background fields. In a model of a self-interacting massive scalar field, conformally coupled to a general asymptotically-flat curved space-time with a trivial topology, momentum-subtractions are shown to respect invariance under general coordinate transformations. As an illustration, general expressions for the trace anomalies are derived, and checked by explicit evaluation of the purely gravitational contributions in the free field theory limit. Furthermore, the trace of the renormalized energy-momentum tensor is shown to vanish at the Gell-Mann Low eigenvalue as it should.

  11. Momentum-subtraction renormalization techniques in curved space-time

    International Nuclear Information System (INIS)

    Foda, O.

    1987-01-01

    Momentum-subtraction techniques, specifically BPHZ and Zimmermann's Normal Product algorithm, are introduced as useful tools in the study of quantum field theories in the presence of background fields. In a model of a self-interacting massive scalar field, conformally coupled to a general asymptotically-flat curved space-time with a trivial topology, momentum-subtractions are shown to respect invariance under general coordinate transformations. As an illustration, general expressions for the trace anomalies are derived, and checked by explicit evaluation of the purely gravitational contributions in the free field theory limit. Furthermore, the trace of the renormalized energy-momentum tensor is shown to vanish at the Gell-Mann Low eigenvalue as it should

  12. Multivariate Spatial Condition Mapping Using Subtractive Fuzzy Cluster Means

    Directory of Open Access Journals (Sweden)

    Hakilo Sabit

    2014-10-01

    Full Text Available Wireless sensor networks are usually deployed for monitoring given physical phenomena taking place in a specific space and over a specific duration of time. The spatio-temporal distribution of these phenomena often correlates to certain physical events. To appropriately characterise these events-phenomena relationships over a given space for a given time frame, we require continuous monitoring of the conditions. WSNs are perfectly suited for these tasks, due to their inherent robustness. This paper presents a subtractive fuzzy cluster means algorithm and its application in data stream mining for wireless sensor systems over a cloud-computing-like architecture, which we call sensor cloud data stream mining. Benchmarking on standard mining algorithms, the k-means and the FCM algorithms, we have demonstrated that the subtractive fuzzy cluster means model can perform high quality distributed data stream mining tasks comparable to centralised data stream mining.

  13. Multivariate Spatial Condition Mapping Using Subtractive Fuzzy Cluster Means

    Science.gov (United States)

    Sabit, Hakilo; Al-Anbuky, Adnan

    2014-01-01

    Wireless sensor networks are usually deployed for monitoring given physical phenomena taking place in a specific space and over a specific duration of time. The spatio-temporal distribution of these phenomena often correlates to certain physical events. To appropriately characterise these events-phenomena relationships over a given space for a given time frame, we require continuous monitoring of the conditions. WSNs are perfectly suited for these tasks, due to their inherent robustness. This paper presents a subtractive fuzzy cluster means algorithm and its application in data stream mining for wireless sensor systems over a cloud-computing-like architecture, which we call sensor cloud data stream mining. Benchmarking on standard mining algorithms, the k-means and the FCM algorithms, we have demonstrated that the subtractive fuzzy cluster means model can perform high quality distributed data stream mining tasks comparable to centralised data stream mining. PMID:25313495

  14. Noise Reduction using Frequency Sub-Band Adaptive Spectral Subtraction

    Science.gov (United States)

    Kozel, David

    2000-01-01

    A frequency sub-band based adaptive spectral subtraction algorithm is developed to remove noise from noise-corrupted speech signals. A single microphone is used to obtain both the noise-corrupted speech and the estimate of the statistics of the noise. The statistics of the noise are estimated during time frames that do not contain speech. These statistics are used to determine if future time frames contain speech. During speech time frames, the algorithm determines which frequency sub-bands contain useful speech information and which frequency sub-bands contain only noise. The frequency sub-bands, which contain only noise, are subtracted off at a larger proportion so the noise does not compete with the speech information. Simulation results are presented.

  15. Suppressive Subtraction Hybridization on Stimulated Primary Horse Macrophages

    Directory of Open Access Journals (Sweden)

    J. Matiašovic

    2006-01-01

    Full Text Available To study genes potentially involved in genetic resistance to infectious diseases in the horse, suppressive subtraction hybridization was used to identify genes expressed in primary horse macrophages after their stimulation with E. coli. Overnight culture of blood monocyte-derived macrophage cells was stimulated with E. coli K12 in ratio 40 E. coli cells to one macrophage cell. After 4 hours of incubation, non-phagocyted bacteria were washed away. Following next 20 hour incubation in MEM alpha containing 5 μg of gentamycin in 1 ml of media, mRNA was isolated and used in Clontech PCR-Select cDNA Subtraction Kit. Expression of several known horse genes, as well as some new ESTs (expressed sequence tags showing sequence similarity with immunity-related genes from other species was identified.

  16. Bone subtraction radiography in adult patients with cystic fibrosis.

    Science.gov (United States)

    Obmann, Verena C; Christe, Andreas; Ebner, Lukas; Szucs-Farkas, Zsolt; Ott, Sebastian R; Yarram, Sai; Stranzinger, Enno

    2017-08-01

    Background Bone subtraction radiography allows reading pulmonary changes of chest radiographs more accurately without superimposition of bones. Purpose To evaluate the value of bone subtraction chest radiography using dual energy (DE) bone subtracted lung images compared to conventional radiographs (CR) in adult patients with cystic fibrosis (CF). Material and Methods Forty-nine DE radiographs of 24 patients (16 men) with CF (mean age, 32 years; age range, 18-71 years) were included. Lung function tests were performed within 10 days of the radiographs. Two radiologists evaluated all CR, DE, and CR + DE radiographs using the modified Chrispin-Norman score (CNS) and a five-point score for the confidence. Findings were statistically evaluated by Friedman ANOVA and Wilcoxon matched-pairs test. Results There was significant difference of CNS between CR and DE ( P = 0.044) as well as CR and CR + DE ( P < 0.001). CNS of CR images showed moderate correlation with FEV1% (R = 0.287, P = 0.046) while DE and CR + DE correlated poorly with FEV1% (R = 0.023, P = 0.874 and R = 0.04, P = 0.785). A higher confidence was achieved with bone-subtracted radiographs compared to radiographs alone (median, CR 3.3, DE 3.9, CR + DE 4.1, for both P < 0.001). Conclusion DE radiographs are reliable for the evaluation of adult patients with CF in acute exacerbation. For yearly surveillance, CR and DE radiographs may play a limited role. However, in clinical routine, DE radiographs are useful for adult CF patients and may depict more accurately inflammatory changes than CR.

  17. N-jettiness Subtractions for NNLO QCD calculations

    Energy Technology Data Exchange (ETDEWEB)

    Gaunt, Jonathan R.; Stahlhofen, Maximilian; Tackmann, Frank J. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Theory Group; Walsh, Jonathan R. [California Univ., CA (United States). Lawrence Berkeley National Laboratory; California Univ., CA (United States). Berkeley Center for Theoretical Physics

    2015-05-15

    We present a subtraction method utilizing the N-jettiness observable, Τ{sub N}, to perform QCD calculations for arbitrary processes at next-to-next-to-leading order (NNLO). Our method employs soft-collinear effective theory (SCET) to determine the IR singular contributions of N-jet cross sections for Τ{sub N} → 0, and uses these to construct suitable Τ{sub N}-subtractions. The construction is systematic and economic, due to being based on a physical observable. The resulting NNLO calculation is fully differential and in a form directly suitable for combining with resummation and parton showers. We explain in detail the application to processes with an arbitrary number of massless partons at lepton and hadron colliders together with the required external inputs in the form of QCD amplitudes and lower-order calculations. We provide explicit expressions for the Τ{sub N}-subtractions at NLO and NNLO. The required ingredients are fully known at NLO, and at NNLO for processes with two external QCD partons. The remaining NNLO ingredient for three or more external partons can be obtained numerically with existing NNLO techniques. As an example, we employ our method to obtain the NNLO rapidity spectrum for Drell-Yan and gluon-fusion Higgs production. We discuss aspects of numerical accuracy and convergence and the practical implementation. We also discuss and comment on possible extensions, such as more-differential subtractions, necessary steps for going to N{sup 3}LO, and the treatment of massive quarks.

  18. N-jettiness subtractions for NNLO QCD calculations

    Energy Technology Data Exchange (ETDEWEB)

    Gaunt, Jonathan R.; Stahlhofen, Maximilian; Tackmann, Frank J. [Theory Group, Deutsches Elektronen-Synchrotron (DESY),Notkestraße 85, D-22607 Hamburg (Germany); Walsh, Jonathan R. [Lawrence Berkeley National Laboratory, University of California,Berkeley, CA 94720 (United States); Berkeley Center for Theoretical Physics, University of California,Berkeley, CA 94720 (United States)

    2015-09-10

    We present a subtraction method utilizing the N-jettiness observable, T{sub N}, to perform QCD calculations for arbitrary processes at next-to-next-to-leading order (NNLO). Our method employs soft-collinear effective theory (SCET) to determine the IR singular contributions of N-jet cross sections for T{sub N}→0, and uses these to construct suitable T{sub N}-subtractions. The construction is systematic and economic, due to being based on a physical observable. The resulting NNLO calculation is fully differential and in a form directly suitable for combining with resummation and parton showers. We explain in detail the application to processes with an arbitrary number of massless partons at lepton and hadron colliders together with the required external inputs in the form of QCD amplitudes and lower-order calculations. We provide explicit expressions for the T{sub N}-subtractions at NLO and NNLO. The required ingredients are fully known at NLO, and at NNLO for processes with two external QCD partons. The remaining NNLO ingredient for three or more external partons can be obtained numerically with existing NNLO techniques. As an example, we employ our results to obtain the NNLO rapidity spectrum for Drell-Yan and gluon-fusion Higgs production. We discuss aspects of numerical accuracy and convergence and the practical implementation. We also discuss and comment on possible extensions, such as more-differential subtractions, necessary steps for going to N{sup 3}LO, and the treatment of massive quarks.

  19. Temporal subtraction contrast-enhanced dedicated breast CT

    Science.gov (United States)

    Gazi, Peymon M.; Aminololama-Shakeri, Shadi; Yang, Kai; Boone, John M.

    2016-09-01

    The development of a framework of deformable image registration and segmentation for the purpose of temporal subtraction contrast-enhanced breast CT is described. An iterative histogram-based two-means clustering method was used for the segmentation. Dedicated breast CT images were segmented into background (air), adipose, fibroglandular and skin components. Fibroglandular tissue was classified as either normal or contrast-enhanced then divided into tiers for the purpose of categorizing degrees of contrast enhancement. A variant of the Demons deformable registration algorithm, intensity difference adaptive Demons (IDAD), was developed to correct for the large deformation forces that stemmed from contrast enhancement. In this application, the accuracy of the proposed method was evaluated in both mathematically-simulated and physically-acquired phantom images. Clinical usage and accuracy of the temporal subtraction framework was demonstrated using contrast-enhanced breast CT datasets from five patients. Registration performance was quantified using normalized cross correlation (NCC), symmetric uncertainty coefficient, normalized mutual information (NMI), mean square error (MSE) and target registration error (TRE). The proposed method outperformed conventional affine and other Demons variations in contrast enhanced breast CT image registration. In simulation studies, IDAD exhibited improvement in MSE (0-16%), NCC (0-6%), NMI (0-13%) and TRE (0-34%) compared to the conventional Demons approaches, depending on the size and intensity of the enhancing lesion. As lesion size and contrast enhancement levels increased, so did the improvement. The drop in the correlation between the pre- and post-contrast images for the largest enhancement levels in phantom studies is less than 1.2% (150 Hounsfield units). Registration error, measured by TRE, shows only submillimeter mismatches between the concordant anatomical target points in all patient studies. The algorithm was

  20. [Construction of a subtracted cDNA library of chronic intermittent hypoxia rabbit liver by suppression subtractive hybridization].

    Science.gov (United States)

    Wu, Yue-tao; Liu, Rui-hong; Yang, Yu; Luo, Ying-quan; Rong, Yao

    2007-12-01

    To construct a subtracted cDNA library of chronic intermittent hypoxia (CIH) rabbit liver by suppression subtractive hybridization (SSH). Twenty-four rabbits were divided into 4 groups: ordinary feeding group, full-fat food group, ordinary feeding in chronic intermittent hypoxia group, and full-fat food in chronic intermittent hypoxia group. The mRNAs were extracted from different rabbit livers and converted into double-strand cDNA. After digestion with restriction enzyme, the cDNA of hyperlipidemia-sensitive rabbit group was subdivided into 2 portions and each one was lighted with different adaptors. Two rounds of both hybridization and suppression PCR obtained the differentially expressed cDNA. The PCR products were inserted into T/A vector to set up the subtractive cDNA library. The clones were selected and amplified by PCR and identified. Based on the pathology of the abdominal aorta and liver, and the amplified library contained 500 positive bacteria clones, including 462 clones, which had inserts from 250 to 700 bp by PCR analysis. A novel rabbit gene, Cthrc1, involved in CHI had been cloned. The GenBank Accession Number is XM_418373. The molecular mechanism of CIH promoting atherogenesis formation is made clear.

  1. The Role of Bone Subtraction Computed Tomographic Angiography in Determining Intracranial Aneurysms in Non-Traumatic Subarachnoid Hemorrhage

    International Nuclear Information System (INIS)

    Kayhan, Aysegul; Koc, Osman; Keskin, Suat; Keskin, Fatih

    2014-01-01

    The presence of blood in the subarachnoid space is an acute pathology with a serious risk of death and complications. The most common etiology (approximately 80%) is intracranial aneurysm. The aim of this study was to assess the role of bone subtracted computed tomographic angiography (BSCTA), a novel and noninvasive method for determining and characterizing intracranial aneurysms. Sixty consecutive patients with clinically suspected non-traumatic subarachnoid hemorrhage (SAH) were considered to enter the study. The subtraction quality was inadequate in ten patients; thus, they were excluded, leaving 50 patients (84.4%) in the study. Bone subtracted and non-subtracted 3D images were obtained from the BSCTA raw data sets. All images obtained by digital subtraction angiography (DSA), BSCTA, and computed tomographic angiography (CTA) were evaluated for the presence or absence of an aneurysm and the location, minimal sac diameter, and neck size ratio of the aneurysm. DSA was considered as the gold standard during the evaluation of the data. Of the 50 patients who participated in this study, 11 had no aneurysms as determined by both CTA and DSA. Examination of the remaining 39 patients revealed the presence of 51 aneurysms. While 3D-CTA could not detect six aneurysms that were located in the base of the skull, 3D-BSCTA easily detected them. Moreover, five aneurysms were only partially detected by 3D-CTA. According to this data, the sensitivity of 3D-BSCTA and 3D-CTA was calculated as 98% and 86.3%, respectively; the specificity was calculated as 100% and 90.9%, respectively, per aneurysm; and the sensitivity of 100% for 3D-BSCTA and 98% for 3D-CTA was achieved by using combined images with multi-planar reconstruction (MPR) and maximum intensity projection (MIP). BSCTA detected and characterized the aneurysms as well as DSA, and BSCTA and DSA gave concordant results in detecting aneurysms. BSCTA is easily accessible, less time consuming, and most importantly, a non

  2. The Role of Bone Subtraction Computed Tomographic Angiography in Determining Intracranial Aneurysms in Non-Traumatic Subarachnoid Hemorrhage

    Science.gov (United States)

    Kayhan, Aysegul; Koc, Osman; Keskin, Suat; Keskin, Fatih

    2014-01-01

    Background: The presence of blood in the subarachnoid space is an acute pathology with a serious risk of death and complications. The most common etiology (approximately 80%) is intracranial aneurysm. Objectives: The aim of this study was to assess the role of bone subtracted computed tomographic angiography (BSCTA), a novel and noninvasive method for determining and characterizing intracranial aneurysms. Patients and Methods: Sixty consecutive patients with clinically suspected non-traumatic subarachnoid hemorrhage (SAH) were considered to enter the study. The subtraction quality was inadequate in ten patients; thus, they were excluded, leaving 50 patients (84.4%) in the study. Bone subtracted and non-subtracted 3D images were obtained from the BSCTA raw data sets. All images obtained by digital subtraction angiography (DSA), BSCTA, and computed tomographic angiography (CTA) were evaluated for the presence or absence of an aneurysm and the location, minimal sac diameter, and neck size ratio of the aneurysm. DSA was considered as the gold standard during the evaluation of the data. Results: Of the 50 patients who participated in this study, 11 had no aneurysms as determined by both CTA and DSA. Examination of the remaining 39 patients revealed the presence of 51 aneurysms. While 3D-CTA could not detect six aneurysms that were located in the base of the skull, 3D-BSCTA easily detected them. Moreover, five aneurysms were only partially detected by 3D-CTA. According to this data, the sensitivity of 3D-BSCTA and 3D-CTA was calculated as 98% and 86.3%, respectively; the specificity was calculated as 100% and 90.9%, respectively, per aneurysm; and the sensitivity of 100% for 3D-BSCTA and 98% for 3D-CTA was achieved by using combined images with multi-planar reconstruction (MPR) and maximum intensity projection (MIP). BSCTA detected and characterized the aneurysms as well as DSA, and BSCTA and DSA gave concordant results in detecting aneurysms. Conclusions: BSCTA is

  3. Chest imaging with dual-energy substraction digital tomosynthesis

    International Nuclear Information System (INIS)

    Sone, S.; Kasuga, T.; Sakai, F.; Hirano, H.; Kubo, K.; Morimoto, M.; Takemura, K.; Hosoba, M.

    1993-01-01

    Dual-energy subtraction digital tomosynthesis with pulsed X-ray and rapid kV switching was used to examine calcifications in pulmonary lesions. The digital tomosynthesis system used included a conventional fluororadiographic TV unit with linear tomographic capabilities, a high resolution videocamera, and an image processing unit. Low-voltage, high voltage, and soft tissue subtracted or bone subtracted tomograms of any desired layer height were reconstructed from the image data acquired during a single tomographic swing. Calcifications, as well as their characteristics and distribution in pulmonary lesions, were clearly shown. The images also permitted discrimination of calcifications from dense fibrotic lesions. This technique was effective in demonstrating calcifications together with a solitary mass or disseminated nodules. (orig.)

  4. Adding and subtracting vectors: The problem with the arrow representation

    Directory of Open Access Journals (Sweden)

    Andrew F. Heckler

    2015-01-01

    Full Text Available A small number of studies have investigated student understanding of vector addition and subtraction in generic or introductory physics contexts, but in almost all cases the questions posed were in the vector arrow representation. In a series of experiments involving over 1000 students and several semesters, we investigated student understanding of vector addition and subtraction in both the arrow and algebraic notation (using i[over ^], j[over ^], k[over ^] in generic mathematical and physics contexts. First, we replicated a number of previous findings of student difficulties in the arrow format and discovered several additional difficulties, including the finding that different relative arrow orientations can prompt different solution paths and different kinds of mistakes, which suggests that students need to practice with a variety of relative orientations. Most importantly, we found that average performance in the ijk format was typically excellent and often much better than performance in the arrow format in either the generic or physics contexts. Further, while we find that the arrow format tends to prompt students to a more physically intuitive solution path, we also find that, when prompted, student solutions in the ijk format also display significant physical insights into the problem. We also find a hierarchy in correct answering between the two formats, with correct answering in the ijk format being more fundamental than for the arrow format. Overall, the results suggest that many student difficulties with these simple vector problems lie with the arrow representation itself. For instruction, these results imply that introducing the ijk notation (or some equivalent with the arrow notation concurrently may be a very useful way to improve student performance as well as help students to learn physics concepts involving vector addition and subtraction.

  5. Addition and subtraction by students with Down syndrome

    Science.gov (United States)

    Noda Herrera, Aurelia; Bruno, Alicia; González, Carina; Moreno, Lorenzo; Sanabria, Hilda

    2011-01-01

    We present a research report on addition and subtraction conducted with Down syndrome students between the ages of 12 and 31. We interviewed a group of students with Down syndrome who executed algorithms and solved problems using specific materials and paper and pencil. The results show that students with Down syndrome progress through the same procedural levels as those without disabilities though they have difficulties in reaching the most abstract level (numerical facts). The use of fingers or concrete representations (balls) appears as a fundamental process among these students. As for errors, these vary widely depending on the students, and can be attributed mostly to an incomplete knowledge of the decimal number system.

  6. A subtractive approach to interior intrusion detection system design

    International Nuclear Information System (INIS)

    Sons, R.J.; Graham, R.H. Jr.

    1986-01-01

    This paper discusses the subtractive approach to interior intrusion detection system design which assumes that all sensors are viable candidates until they are subjected to the constraints imposed by a particular facility. The constraints are determined by a sequence of questions concerning parameters such as threat definition, facility description and operation, environment, assets to be protected, security system capabilities, and cost. As a result of the questioning, some sensors will be eliminated from the candidate list, and the ''best'' set of sensors for the facility will remain. This form of questioning could be incorporated into an expert system aiding future intrusion detection system designs

  7. Generation of Fuzzy Rules by Subtractive ‎ Clustering

    Directory of Open Access Journals (Sweden)

    Hussen Ateya Lafta

    2017-12-01

    Full Text Available This work depends on two stages. First one, "subtractive method", clustering algorithm, used for identifying the relationships between data points in order to build system, where the data point gathers with other points to make cluster of the same features. These groups will be used in the second part of the work to construct fuzzy IF…THEN rules, which controls how the system works. The number of rules and its parts depend on these clusters. While the Takagi-Sugeno Kang (TSK fuzzy inference modal was used. The scope of this work is applied to heart disease diagnosis.

  8. Multiple-energy X-ray subtraction imaging system

    International Nuclear Information System (INIS)

    Brody, WR.

    1982-01-01

    This invention relates to x-ray imaging systems, with particular reference to blood vessels. In a primary application the invention relates to obtaining isolated images of an administered contrast agent. The absorption of X-rays transmitted through a body is measured in a plurality of energy ranges and these measurements are processed to obtain image data with the soft tissue component eliminated. Such processed image data is obtained before and after the administration of a contrast agent, such as iodine, to the body. The two sets of processed image data are subtractively combined to obtain an isolated image of the contrast agent which is immune to motion of soft tissue. (author)

  9. Renal artery digital-substraction angiography. An outpatient investigation for renovascular hypertension

    International Nuclear Information System (INIS)

    Jackson, B.; Dugdale, L.

    1985-01-01

    The adequacy and convenience of the digital-substraction angiographic procedure by means of a Diasonics DF100 as an investigation in renovascular disease were assessed in 82 renal artery studies. The major advantage of digital subtraction angiography of the renal artery over conventional angiography is that it can be performed on an outpatient basis

  10. Digital X-ray Imaging in Dentistry

    International Nuclear Information System (INIS)

    Kim, Eun Kyung

    1999-01-01

    In dentistry, Radio Visio Graphy was introduced as a first electronic dental x-ray imaging modality in 1989. Thereafter, many types of direct digital radiographic systems have been produced in the last decade. They are based either on charge-coupled device (CCD) or on storage phosphor technology. In addition, new types of digital radiographic system using amorphous selenium, image intensifier etc. are under development. Advantages of digital radiographic system are elimination of chemical processing, reduction in radiation dose, image processing, computer storage, electronic transfer of images and so on. Image processing includes image enhancement, image reconstruction, digital subtraction, etc. Especially digital subtraction and reconstruction can be applied in many aspects of clinical practice and research. Electronic transfer of images enables filmless dental hospital and teleradiology/teledentistry system. Since the first image management and communications system (IMACS) for dentomaxillofacial radiology was reported in 1992, IMACS in dental hospital has been increasing. Meanwhile, researches about computer-assisted diagnosis, such as structural analysis of bone trabecular patterns of mandible, feature extraction, automated identification of normal landmarks on cephalometric radiograph and automated image analysis for caries or periodontitis, have been performed actively in the last decade. Further developments in digital radiographic imaging modalities, image transmission system, imaging processing and automated analysis software will change the traditional clinical dental practice in the 21st century.

  11. Digital X-ray Imaging in Dentistry

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Dankook University, Yongin (Korea, Republic of)

    1999-08-15

    In dentistry, Radio Visio Graphy was introduced as a first electronic dental x-ray imaging modality in 1989. Thereafter, many types of direct digital radiographic systems have been produced in the last decade. They are based either on charge-coupled device (CCD) or on storage phosphor technology. In addition, new types of digital radiographic system using amorphous selenium, image intensifier etc. are under development. Advantages of digital radiographic system are elimination of chemical processing, reduction in radiation dose, image processing, computer storage, electronic transfer of images and so on. Image processing includes image enhancement, image reconstruction, digital subtraction, etc. Especially digital subtraction and reconstruction can be applied in many aspects of clinical practice and research. Electronic transfer of images enables filmless dental hospital and teleradiology/teledentistry system. Since the first image management and communications system (IMACS) for dentomaxillofacial radiology was reported in 1992, IMACS in dental hospital has been increasing. Meanwhile, researches about computer-assisted diagnosis, such as structural analysis of bone trabecular patterns of mandible, feature extraction, automated identification of normal landmarks on cephalometric radiograph and automated image analysis for caries or periodontitis, have been performed actively in the last decade. Further developments in digital radiographic imaging modalities, image transmission system, imaging processing and automated analysis software will change the traditional clinical dental practice in the 21st century.

  12. Intravenous Therapy: Hazards, Complications and Their Prevention ...

    African Journals Online (AJOL)

    In this review article, the local and systemic complications of intravenous therapy are highlighted and their preventive measures are discussed. Intravenous therapy exposes the patient to numerous hazards and many of them are avoidable, if the health care provider understands the risks involved and acts appropriately and ...

  13. Intentional intravenous mercury injection | Yudelowitz | South African ...

    African Journals Online (AJOL)

    Intravenous mercury injection is rarely seen, with few documented cases. Treatment strategies are not clearly defined for such cases, although a few options do show benefit. This case report describes a 29-year-old man suffering from bipolar disorder, who presented following self-inflicted intravenous injection of mercury.

  14. Intravenous immunoglobulin prophylaxis in neonates on artificial ...

    African Journals Online (AJOL)

    The efficacy of the prophylactic use of intravenous immunoglobulin (Ig) was evaluated in a double-blind placebo-controlled trial of 21 pairs of ventilated neonates weighing more than 1 500 g, Each infant received 0.4 g/kglday of intravenous Ig or a similar volume of placebo daily for 5 days. Criteria used to assess the ...

  15. Subtractive fabrication of ferroelectric thin films with precisely controlled thickness

    Science.gov (United States)

    Ievlev, Anton V.; Chyasnavichyus, Marius; Leonard, Donovan N.; Agar, Joshua C.; Velarde, Gabriel A.; Martin, Lane W.; Kalinin, Sergei V.; Maksymovych, Petro; Ovchinnikova, Olga S.

    2018-04-01

    The ability to control thin-film growth has led to advances in our understanding of fundamental physics as well as to the emergence of novel technologies. However, common thin-film growth techniques introduce a number of limitations related to the concentration of defects on film interfaces and surfaces that limit the scope of systems that can be produced and studied experimentally. Here, we developed an ion-beam based subtractive fabrication process that enables creation and modification of thin films with pre-defined thicknesses. To accomplish this we transformed a multimodal imaging platform that combines time-of-flight secondary ion mass spectrometry with atomic force microscopy to a unique fabrication tool that allows for precise sputtering of the nanometer-thin layers of material. To demonstrate fabrication of thin-films with in situ feedback and control on film thickness and functionality we systematically studied thickness dependence of ferroelectric switching of lead-zirconate-titanate, within a single epitaxial film. Our results demonstrate that through a subtractive film fabrication process we can control the piezoelectric response as a function of film thickness as well as improve on the overall piezoelectric response versus an untreated film.

  16. Counting the mismatches - lung ventilation/perfusion subtraction index

    International Nuclear Information System (INIS)

    Anderson, T.C.; Evans, S.G.; Larcos, G.; Farlow, D.C.

    1998-01-01

    Full text: There is potential for interobserver variability in interpretation of ventilation/perfusion (V/Q) scans. Objective quantification of V/Q mismatch could be useful. Thus, the aim of this study is to determine the validity of image subtraction in a group of 27 patients (11 men, 8 women; mean age 59.4 years [range 21-81 years])investigated by V/Q scans for suspected pulmonary emboli. A standard 6 view V/Q scan was obtained with two cobalt markers used on the anterior and posterior surfaces for image alignment. Ventilation images were normalised to the perfusion using an area of normal ventilation and perfusion. With the use of automated, and if required, manual alignment, perfusion images were subtracted from ventilation, with a median filter applied. A summed index of mismatch for each lung scan was calculated from the difference. This index was then retrospectively compared to the result reported by one of four experienced physicians. Two patients with chronic obstructive airways disease were excluded from analysis. We conclude that high probability V/Q scans can be differentiated from low probability studies using this index; further prospective investigation in a larger cohort is warranted

  17. Background fog subtraction methods in Gafchromic® dosimetry

    International Nuclear Information System (INIS)

    Gueli, Anna M.; Cavalli, Nina; De Vincolis, Renato; Raffaele, Luigi

    2015-01-01

    We compared three different background fog subtraction methods in order to evaluate their influence on the dose calculation by Gafchromic ® films. The research has involved both scanner response uniformity and effects of each method in the Net Optical Density (NOD) determination and dose evaluation. The dosimetric system is set-up by a flatbed scanner EPSON Perfection Pro 750 and External Beam Therapy films (EBT3 model). Photon beams (6 MV), provided by a Siemens Oncor Impression Linear Accelerator, have been used for film irradiation, covering the 0.5–50 Gy range. A clinical proton beam, produced by a superconducting cyclotron, has been used to test the different techniques. Results allow us to define an easy and fast protocol for application, with the accuracy and the precision adequate to clinical practice needs. - Highlights: • Three background fog subtraction methods are studied. • An exponential law is used to test the influence of each method on calibration. • A protocol user friendly and very low time consuming was identified

  18. Robust baseline subtraction for ultrasonic full wavefield analysis

    Science.gov (United States)

    Alguri, K. Supreet; Michaels, Jennifer E.; Harley, Joel B.

    2017-02-01

    Full wavefield analysis is used to study and characterize the interaction between waves and structural damage. Yet, as wavefields are measured and as damage evolves in a structure, environmental and operational variations can significantly affect wave propagation. Several approaches, including time-stretching and optimal baseline selection methods, can reduce variations, but these methods are often limited to specific effects, are ineffective for large environmental variations, or require an impractical number of prior baseline measurements. This paper presents a robust methodology for subtracting wavefields and isolating wave-damage interactions. The method is based on dictionary learning. It is robust to multiple types of environmental and operational variations and requires only one initial baseline. We learn the dictionary, which describes wave propagation for a particular wavefield, based on multiple frequencies of a baseline wavefield. We then use the dictionary and sparse regression to create new baselines for measurements with different environmental and operational conditions. The new baseline is then subtracted from the new wavefield to isolate damage wavefield.

  19. [sup 99m]Tc-RBC subtraction scintigraphy; Assessmet of bleeding site and rate

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru (Toyama Medical and Pharmaceutical Univ. (Japan). Hospital)

    1994-03-01

    Sequential abdominal scintigrams with [sup 99m]Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author).

  20. Rescue localized intra-arterial thrombolysis for hyperacute MCA ischemic stroke patients after early non-responsive intravenous tissue plasminogen activator therapy

    International Nuclear Information System (INIS)

    Kim, Dong Joon; Kim, Dong Ik; Kim, Seo Hyun; Lee, Kyung Yeol; Heo, Ji Hoe; Han, Sang Won

    2005-01-01

    The outcome of patients who show no early response to intravenous (i.v.) tissue plasminogen activator (tPA) therapy is poor. The objective of this study was to evaluate the feasibility of rescue localized intra-arterial thrombolysis (LIT) therapy for acute ischemic stroke patients after an early non-responsive i.v. tPA therapy. Patients with proximal MCA occlusions who were treated by LIT (n=10) after failure of early response [no improvement or improvement of National Institute of Health Stroke Scale (NIHSS) scores of ≤3] to i.v. tPA therapy (0.9 mg/kg - 10% bolus and 90% i.v. infusion over 60 min) were selected. The recanalization rates, incidence of post-thrombolysis hemorrhage and clinical outcomes [baseline and discharge NIHSS scores, mortality, 3 months Barthel index (BI) and modified Rankin score (mRS)] were evaluated. Rescue LIT therapy was performed on ten MCA occlusion patients (male:female=3:7, mean age 71 years). The mean time between the initiation of i.v. tPA therapy and the initiation of intra-arterial urokinase (i.a. UK) was 117±25.0 min [time to i.v. tPA 137±32 min; time to digital subtraction angiography (DSA) 221±42 min; time to i.a. UK 260±46 min]. The baseline NIHSS scores showed significant improvement at discharge (median from 18 to 6). Symptomatic hemorrhage and, consequent, mortality were noted in 2/10 (20%) patients. Three months good outcome was noted in 4/10 (40%, mRS 0-2) and 3/10 (30%, BI ≥95). In conclusion, rescue LIT therapy can be considered as a treatment option for patients not showing early response to full dose i.v. tPA therapy. Larger scale studies for further validation of this protocol may be necessary. (orig.)

  1. Digital subtraction angiography in evaluation of vascular supply of head and neck paragangliomas

    International Nuclear Information System (INIS)

    Juszkat, R.; Szyfter, P.; Zarzecka, A.

    2008-01-01

    Paragangliomas (PGs) of the head and neck are relatively rare and represent 0.6% of all head and neck tumors and 0.03% of all tumors. There are four groups of head and neck PGs: carotid body tumors, vagal PGs, jugular PGs, and tympanic PGs. The resection of head and neck PGs carries an inherent risk of injury to cranial nerves and vascular structures which may lead to excessive bleeding. To plan the surgical strategy for PGs, detailed information about the vascular supply of the tumor is required. Between January 1998 and April 2007, 41 tumors of the head and neck were identified in 37 patients (20 females, 17 males, mean age: 38.4 years). Single tumors were observed in 33 patients, two head and neck PGs were identified in 3 patients, and 1 patient presented 3 PGs, one of which was located laterally to the aortic arch. There were 21 PGs located at the carotid bifurcation, 10 in the jugular foramen, 6 in the tympanic cavity, and 4 along the course of the vagus nerve. In all the cases of PGs located in the head and neck, the vascular supply came from branches of the external carotid artery. Vascular supply from the internal carotid and the vertebral arteries was not seen in any of the patients. The most common vascular supply in the cases of carotid body tumors and jugular PGs was the pharyngeal ascending artery. In the cases of vagal PGs it was the pharyngeal ascending artery and the posterior auricular artery and in the case of tympanic PGs the posterior auricular artery. DSA is an important tool in the diagnosis of head and neck PGs. The evaluation of its vascularization is essential in planning further treatment, both endovascular and surgical. (author)

  2. Differential analysis of contraction of the cardiac chambers by digital subtraction angiography

    International Nuclear Information System (INIS)

    Christ, F.; Nitsch, J.; Franken, T.; Manz, M.; Becher, H.; Bonn Univ.

    1986-01-01

    One hundred and thirty-six patients with various cardiac abnormalities that had been diagnosed by standard methods, were examined by I-V DSA; images of the left and right ventricles during a representative cardiac cycle were submitted to amplitude and phase analysis, using a Fourier transformation. Temporal differentiation of ventricular function was derived from the best available right anterior oblique projection; the amplitude of cardiac movement of abnormal areas in the myocardium were obtained from a grey scale or colour coding at a fixed point. Comparison with a control group of 35 individuals showed the following pathological findings: hypokinetic segments (33 cases) showed delay, dyskinesias (20 cases) showed complete separation of maximal phases, frequently with a double peak in the phase histogram; disturbances of cardiac rhythm (14 cases) showed atypical localisation of initiation of contraction: in Wolfe-Parkinson-White syndrome this is basal-anterior, in left bundle branch block and VVI stimulation it is apical inferior; in hypertrophic obstructive cardiomyopathy (eight cases) it is postero-basal inferior with high, narrow peaks on the phase histogram. Differential phase analysis on I-V DSA enables one to define cardiac contraction in a simple manner. (orig.) [de

  3. Vertebrocarotid collateral in extracranial carotid artery occlusions: digital subtraction angiography findings

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Kizilkilic, Osman; Tercan, Fahri; Tuerkoez, Riza; Yildirim, Tuelin

    2005-01-01

    The internal and external carotid arteries are usually considered occluded distal to a common carotid artery occlusion but some collateral vessels may provide blood keeping the internal and external carotid arteries patent distal to the occlusion. Most common communication in such a case is diversion of blood from muscular branches of the vertebral artery to occipital branch of the external carotid artery which in turn could maintain blood flow into the internal carotid artery, a condition called carotid steal. We encountered vertebrocarotid anastomoses maintaining the patency of carotid circulation in six patients. Patients were four females and two males, ages ranging from 40 to 67 (mean age: 56) years. Five of the patients had ischemic cerebral symptoms. The origin of the external carotid artery was occluded in two and the whole common carotid artery in the remaining four patients. Two patients had double steal, carotid and subclavian at the same time. There was also severe stenosis or occlusion of at least one other major extracranial cerebral artery in all the cases. This concomitant involvement of the second extracranial cerebral artery was thought to be the main reason for the development of vertebrocarotid collateral. In contrast to most of the previously published reports claiming the inadequacy of angiography when compared with colour Doppler ultrasonography, angiography finely depicted the distal patency of the carotid circulation and all the collaterals in detail in every case. Selective injection of the vertebral artery ipsilateral to the occlusion, is the key to demonstrate distal patency of the carotid circulation in cases of proximal carotid occlusion. Demonstration of patency of the distal circulation is very important because some of the patients might get benefit from a reconstructive surgery

  4. Temporal Subtraction of Digital Breast Tomosynthesis Images for Improved Mass Detection

    Science.gov (United States)

    2009-11-01

    isosurface function, which renders a polygon surface mesh in volumetric data. The surface model includes all of the intricate tissue connections within...Dobbins, III, "A rapid and automatic image registration algorithm with subpixel accuracy," IEEE Trans Med Imag 16, 308-316 (1997). Appendix 1. C...04 Nov 2009 to 152.16.179.18. Terms of Use: http://spiedl.org/terms Figure 2: Surface rendering of the skin is shown on the left and an

  5. Digital subtraction angiography in patients with Marfan's syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Rauber, K.; Riemann, H.

    1987-06-01

    Marfan's syndrome is a rare inborn error of metabolism. Marfan patients are prone to aneurysms of the ascending aorta and run a high risk of rupture of the aortic arch. The diameter of the aneurysm is the most important predictor of the risk and therefore the leading point for surgical interventions. IV and IA-DSA according to our experiences are simple and effective methods in pre- and postoperative evaluation of patients with the syndrome.

  6. The value of digital subtraction angiography in diagnosing small intestinal hemorrhage with unknown reasons

    International Nuclear Information System (INIS)

    Luo Guanghua; Xiao Wenlian; Tang Deqiu; Chan Hong

    2006-01-01

    Objective: To discuss the diagnostic value of DSA for unknown reason hemorrhage of small intestine. Methods: 25 patients with hemorrhage of small intestine were performed angiography with Seldinger's technique through superior mesenteric artery. Results: Eleven cases demonstrated direct signs of hemorrhage, 12 cases of indirect signs of hemorrhage and 5 with both of the signs. The positive rate of hemorrhage was 72% including 10 cases of tumor (6 leiomyomas, 2 leiomyosarcomas, 1 interstitial tumor, 1 small intestinal cancer), 4 cases of Meckel's diverticulum, 3 cases of vascular malformation and 1 case of inflammation. The coincidence rate of positive cases with pathology was 75% and the diagnostic accuracy of localization was 100%. Conclusions: DSA angiography is very helpful for determining the location and character of unknown reason hemorrhage of small intestine. (authors)

  7. Comparative evaluation of 64-slice CT angiography and digital subtraction angiography in assessing the cervicocranial vasculature

    Directory of Open Access Journals (Sweden)

    Randolf Klingebiel

    2008-08-01

    Full Text Available Randolf Klingebiel1, Max Kentenich3, Hans-Christian Bauknecht3, Florian Masuhr2, Eberhard Siebert1, Markus Busch2, Georg Bohner11Department of Neuroradiology, 2Department of Neurology, 3Department of Radiology, Charité Universitary Medicine Berlin, GermanyBackground: Noninvasive 64-slice computed tomography angiography (64-MSCTA closely approximates conventional catheter angiography (DSA in terms of detail resolution. Objective: Retrospective evaluation of cervicocranial (cc 64-MSCTA in comparison with DSA in patients with presumptive cc vascular disorders.Material and methods: Twenty-four 64-MSCTA studies (32 mm detector width, slice thickness 0.5 mm, 120 kv, 150 mAs, pitch 0.75 of patients with presumptive cc vascular pathology (13 men, 11 women, mean age 38.3 ± 11.3 yrs, range 19–54 yrs were assessed in comparison with DSA studies without abnormal findings in age-matched patients (11 men, 13 women, mean age 39.7 ± 11.9 yrs, range 18–54 yrs. Study readings were performed in a blinded manner by two neuroradiologists with respect to image quality and assessibility of various cc vascular segments by using a five-point scale. Radiation exposure was calculated for 64-MSCTA.Results: Each reader assessed 384/528 different vessel segments (64-MSCTA/DSA. Superior image quality was attributed to DSA with respect to the C1 ICA–C6 ICA, A3 ACA, and P3 PCA segments as well the AICA and SCA. 64-MSCTA was scored superior for C7 ICA and V4 VA segments. A significantly increased number of nonassessable V2- and V3 VA segments in DSA studies was noted. The effective dose for 64-MSCTA amounted to 2.2 mSv.Conclusions: 64-MSCTA provides near-equivalent diagnostic information of the cc vasculature as compared with DSA. According to our results, DSA should be considered primarily when peripheral vessels (A3/P3 or ICA segments close to the skull base (C2-5 are of interest, such as in primary angiitis or stenoocclusive ICA disease, respectively.Keywords: CT-angiography, CNS, angiography

  8. Conventional renal angiography versus renal digital subtraction angiography (DSA) in the study of renovascular hypertension

    International Nuclear Information System (INIS)

    Essinger, A.; Morsier, B. de; Narbel, M.; Raimondi, S.

    1988-01-01

    A cost-benefit analysis comparing conventional renal angiography, IV and IA DSA and spot film cameras has been made in order to quantify the advantages and disadvantages of these techniques in screening for renal artery stenosis. DSA is the best modality of imaging, using very little films, easy to archive, with a spatial resolution inferior to conventional angiography but partially compensated by contrast resolution. The surface dose per image using a 512/512 matrix is two thirds less than a conventional film, giving thus an acceptable dose as long as technical personnel is well trained and thus the number of exposures is kept low. Spot film camera, due to its excellent spatial resolution, its low radiation dose and its low price, can also be used as a screening procedure but requires an arterial injection. DSA has furthermore the advantage of quantifying renal artery stenosis making future percutaneous transluminal angioplasty easier

  9. Physician evaluation and acceptance of remote transmission of CT, digital subtraction angiography, and US annotated images

    International Nuclear Information System (INIS)

    Haskin, M.E.; Robbins, C.; Kohn, M.; Laffey, P.A.; Haskin, P.H.; Teplick, J.G.; Teplick, S.K.; Peyster, R.G.

    1986-01-01

    The authors have found annotated images an effective way of communicating the results of imaging studies to referring physicians. Of particular value is the collation of representative images from several modalities. Previously, hard copy of this collation was sent to the referring physician as an integrated imaging report. Recently they developed a computer-based station that transmits annotated images to remote personal computer (PC) terminals via a telephone modem which requires 30 seconds to send each image. This annotated image report can be quickly accessed by the referring physician at the remote PC terminal The prototype system, utility, diagnostic fidelity, and potential of this remote system are described

  10. The analysis of cerebro-vascular circulation time using digital subtraction angiography (DSA)

    Energy Technology Data Exchange (ETDEWEB)

    Han, D. G.; Kim, D. H.; Lee, H. K.; Kwon, K. H.; Kim, K. J. [Soonchunhyang University College of Medicine, Asan (Korea, Republic of)

    1986-10-15

    We analyzed the cerebral arterio-venous circulation time of 141 cases of cranial DSA in 136 patients, for the assessment of cerebral circulatory dynamics. IV-DSA was 111 cases, IA-DSA 30 cases. The results were as follows: 1. There was no significant difference in arterio-venous circulation time between IA-DSA and IV-DSA, if the disease pattern was not considered (P > 0.1). 2. Prolongation of arterio-venous circulation time was noted in the cases of cerebral (cerebellar) hemorrhage, subarachnoid hemorrhage, intracranial hematoma, brain abscess, acute stage of cerebra-vascular occlusive disease, acute stage of postoperative follow up, and acute stage of cerebral contusion (p > 0.05). 3. Compared the chronic stage of cerebra-vascular occlusive disease, postoperative follow up, and cerebral contusion with acute stage, significant decrement of arterio-venous circulation time was resulted (p > 0.05). 4. DSA was a useful modality for the assessment of circulatory dynamics, including measurement of arterio-venous circulation time.

  11. Application of MR digital subtraction angiography to the diagnosis of cerebral arteriovenous malformations

    International Nuclear Information System (INIS)

    Katase, Shichiro; Tsuchiya, Kazuhiro; Osawa, Ayako; Hachiya, Junichi

    2000-01-01

    We evaluated the utility of MR DSA using rapid thick-section T1-weighted imaging and bolus injections of gadolinium to diagnose cerebral arteriovenous malformations (AVMs). We reviewed MR DSA images obtained from 16 patients (9 men and 7 women; average age, 35.8 years). Anatomic depictions of each component of the AVMs were rated using a four-point grade scale and compared with conventional and/or MR angiograms. We were able to obtain serial images demonstrating passage of gadolinium through the AVM. The average scores for feeders, nidus, and drainers was 1.4, 2.2, and 1.8, respectively with the overall average of 2.1. The MR DSA technique that we have developed presently has limited value in depicting the anatomic details of cerebral AVMs. However, we believe that MR DSA is valuable and should be used in addition to conventional MR imaging and angiography in patients with cerebral AVM at the time of their initial diagnosis and during follow-up after therapy. (author)

  12. In vivo comparison of tantalum, tungsten, and bismuth enteric contrast agents to complement intravenous iodine for double-contrast dual-energy CT of the bowel.

    Science.gov (United States)

    Rathnayake, Samira; Mongan, John; Torres, Andrew S; Colborn, Robert; Gao, Dong-Wei; Yeh, Benjamin M; Fu, Yanjun

    2016-07-01

    To assess the ability of dual-energy CT (DECT) to separate intravenous contrast of bowel wall from intraluminal contrast, we scanned 16 rabbits on a clinical DECT scanner: n = 3 using only iodinated intravenous contrast, and n = 13 double-contrast enhanced scans using iodinated intravenous contrast and experimental enteric non-iodinated contrast agents in the bowel lumen (five bismuth, four tungsten, and four tantalum based). Representative image pairs from conventional CT images and DECT iodine density maps of small bowel (116 pairs from 232 images) were viewed by four abdominal imaging attending radiologists to independently score each comparison pair on a visual analog scale (-100 to +100%) for (1) preference in small bowel wall visualization and (2) preference in completeness of intraluminal enteric contrast subtraction. Median small bowel wall visualization was scored 39 and 42 percentage points (95% CI 30-44% and 36-45%, both p bismuth contrast. Median completeness of intraluminal enteric contrast subtraction in double-contrast DECT iodine density maps was scored 28 and 29 percentage points (95% CI 15-31% and 28-33%, both p bismuth contrast. Results suggest that in vivo double-contrast DECT with iodinated intravenous and either tantalum- or tungsten-based enteric contrast provides better visualization of small bowel than conventional CT. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Cadmium Subtraction Method for the Active Albedo Neutron Interrogation of Uranium

    Energy Technology Data Exchange (ETDEWEB)

    Worrall, Louise G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-02-01

    This report describes work performed under the Next Generation Safeguards Initiative (NGSI) Cadmium Subtraction Project. The project objective was to explore the difference between the traditional cadmium (Cd) ratio signature and a proposed alternative Cd subtraction (or Cd difference) approach. The thinking behind the project was that a Cd subtraction method would provide a more direct measure of multiplication than the existing Cd ratio method. At the same time, it would be relatively insensitive to changes in neutron detection efficiency when properly calibrated. This is the first published experimental comparison and evaluation of the Cd ratio and Cd subtraction methods.

  14. A posterior registration and subtraction of periapical radiographs for the evaluation of external apical root resorption after orthodontic treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kreich, Eliane Maria; Chibinski, Ana Claudia; Coelho, Ulisses; Wambier, Leticia Stadler; Zedebski, Rosaio De Arruda Moura [School of Dentistry, Ponta Grossa State University, Ponta Grossa, Parana (Brazil); De Moraes, Mari Eli Leonelli; De Moraes, Luiz Cesar [Dept. of Dental Radiology, School of Dentistry, State University of Sao Paulo, Sao Jose dos Campos, Sao Paulo (Brazil)

    2016-03-15

    This study employed a posteriori registration and subtraction of radiographic images to quantify the apical root resorption in maxillary permanent central incisors after orthodontic treatment, and assessed whether the external apical root resorption (EARR) was related to a range of parameters involved in the treatment. A sample of 79 patients (mean age, 13.5±2.2 years) with no history of trauma or endodontic treatment of the maxillary permanent central incisors was selected. Periapical radiographs taken before and after orthodontic treatment were digitized and imported to the Regeemy software. Based on an analysis of the posttreatment radiographs, the length of the incisors was measured using Image J software. The mean EARR was described in pixels and relative root resorption (%). The patient's age and gender, tooth extraction, use of elastics, and treatment duration were evaluated to identify possible correlations with EARR. The mean EARR observed was 15.44±12.1 pixels (5.1% resorption). No differences in the mean EARR were observed according to patient characteristics (gender, age) or treatment parameters (use of elastics, treatment duration). The only parameter that influenced the mean EARR of a patient was the need for tooth extraction. A posteriori registration and subtraction of periapical radiographs was a suitable method to quantify EARR after orthodontic treatment, and the need for tooth extraction increased the extent of root resorption after orthodontic treatment.

  15. A posterior registration and subtraction of periapical radiographs for the evaluation of external apical root resorption after orthodontic treatment

    International Nuclear Information System (INIS)

    Kreich, Eliane Maria; Chibinski, Ana Claudia; Coelho, Ulisses; Wambier, Leticia Stadler; Zedebski, Rosaio De Arruda Moura; De Moraes, Mari Eli Leonelli; De Moraes, Luiz Cesar

    2016-01-01

    This study employed a posteriori registration and subtraction of radiographic images to quantify the apical root resorption in maxillary permanent central incisors after orthodontic treatment, and assessed whether the external apical root resorption (EARR) was related to a range of parameters involved in the treatment. A sample of 79 patients (mean age, 13.5±2.2 years) with no history of trauma or endodontic treatment of the maxillary permanent central incisors was selected. Periapical radiographs taken before and after orthodontic treatment were digitized and imported to the Regeemy software. Based on an analysis of the posttreatment radiographs, the length of the incisors was measured using Image J software. The mean EARR was described in pixels and relative root resorption (%). The patient's age and gender, tooth extraction, use of elastics, and treatment duration were evaluated to identify possible correlations with EARR. The mean EARR observed was 15.44±12.1 pixels (5.1% resorption). No differences in the mean EARR were observed according to patient characteristics (gender, age) or treatment parameters (use of elastics, treatment duration). The only parameter that influenced the mean EARR of a patient was the need for tooth extraction. A posteriori registration and subtraction of periapical radiographs was a suitable method to quantify EARR after orthodontic treatment, and the need for tooth extraction increased the extent of root resorption after orthodontic treatment

  16. Intravenous adenosine SPECT thallium imaging

    International Nuclear Information System (INIS)

    Joyce, J.M.; Grossman, S.J.; Garrett, J.S.; Sharma, B.; Geller, M.; Sweeney, P.J.

    1991-01-01

    This paper determines the safety and efficacy of intravenous (IV) adenosine in females for the evaluation of coronary artery disease, since only limited data are available. Eighty consecutive studies of 78 female subjects (aged 43-83 years) using IV adenosine (0.14 mg/kg per minute) with T1-201 SPECT imaging were reviewed. Fifty-eight (73%) had mild symptoms; mild dyspnea (24%), flushing (23%), chest pain (23%), headache (11%), dizziness (11%), weakness (9%), nausea (8%), abdominal pain (8%), arm pain (6%), chest tightness (4%), neck tightness (4%), dry mouth (4%), and dropped P waves (4%). Four had moderate symptoms: dyspnea requiring Proventil or aminophylline (2%), significant hypotension (1%), and third-degree atrioventicular heart block (1%). Two had severe symptoms (ventricular tachycardia requiring cardioversion (1%) and severe dyspnea requiring epinephrine (1%). Twenty-two (28%) underwent cardiac catheterization that demonstrated coronary artery disease or postangioplasty results. The thallium SPECT images were 94% sensitive and 100% specific in detecting significant disease. The one false-negative result was in a subject who experienced no symptoms for ECG changes during adenosine infusion. Ischemic ECG changes were 35% sensitive and 100% specific. Chest pain was 53% sensitive and 60% specific

  17. The use of subtraction arthrography in total hip arthroplasties

    International Nuclear Information System (INIS)

    Barentsz, J.O.; Lemmens, J.M.; Slooff, T.J.J.H.; Katholieke Univ. Nijmegen

    1986-01-01

    The results of plain film radiogrpahy and subtraction arthrography in 24 patients prior to revision surgery for a loosened total hip arthroplasty (T.H.A.) were compared with operative findings. Loosening of both the acetabular and the femoral components was evaluated. In plain film radiography the overall accurcy for evidence of loosening in 22 acetabular and 23 femoral components was 58% The overall accuracy with arthrography was 93%. Three results were false-negatives; arthrography showing no evidence of loosening, while the arthroplasty was found to be loose on surgical evaluation. The results of this study are compared with findings reported in the literature. Arthrography was performed by a lateral puncture technique. There were no complications. The use of the puncture technique has not been described previously. The extent of contrast leakage into the interfaces is described and discussed. (orig.) [de

  18. Use of subtraction arthrography in total hip arthroplasties

    Energy Technology Data Exchange (ETDEWEB)

    Barentsz, J.O.; Lemmens, J.M.; Slooff, T.J.J.H.

    1986-04-01

    The results of plain film radiogrpahy and subtraction arthrography in 24 patients prior to revision surgery for a loosened total hip arthroplasty (T.H.A.) were compared with operative findings. Loosening of both the acetabular and the femoral components was evaluated. In plain film radiography the overall accurcy for evidence of loosening in 22 acetabular and 23 femoral components was 58% The overall accuracy with arthrography was 93%. Three results were false-negatives; arthrography showing no evidence of loosening, while the arthroplasty was found to be loose on surgical evaluation. The results of this study are compared with findings reported in the literature. Arthrography was performed by a lateral puncture technique. There were no complications. The use of the puncture technique has not been described previously. The extent of contrast leakage into the interfaces is described and discussed.

  19. An Improved Spectral Background Subtraction Method Based on Wavelet Energy.

    Science.gov (United States)

    Zhao, Fengkui; Wang, Jian; Wang, Aimin

    2016-12-01

    Most spectral background subtraction methods rely on the difference in frequency response of background compared with characteristic peaks. It is difficult to extract accurately the background components from the spectrum when characteristic peaks and background have overlaps in frequency domain. An improved background estimation algorithm based on iterative wavelet transform (IWT) is presented. The wavelet entropy principle is used to select the best wavelet basis. A criterion based on wavelet energy theory to determine the optimal iteration times is proposed. The case of energy dispersive X-ray spectroscopy is discussed for illustration. A simulated spectrum with a prior known background and an experimental spectrum are tested. The processing results of the simulated spectrum is compared with non-IWT and it demonstrates the superiority of the IWT. It has great significance to improve the accuracy for spectral analysis. © The Author(s) 2016.

  20. Background subtraction system for pulsed neutron logging of earth boreholes

    International Nuclear Information System (INIS)

    Hopkinson, E.C.

    1977-01-01

    A neutron generator in well logging instrument is pulsed 100 times having a time between pulses of 1400 microseconds. This is followed by an off period of four cycles wherein 2800 microseconds is allowed for capture radiation to decay to an insignificant level and the remaining 2800 microseconds is used to measure background radiation. This results in the neutron source being disabled four pulses after every hundred pulses of operation, or approximately a 4 percent loss of neutron output. A first detector gate is open from 400 to 680 microseconds and a second detector gate is open from 700 to 980 microseconds. During the 100 cycles, each of the gates is thus open for 280 microseconds times 100 for a total of 28,000 microseconds. By scaling the gate count rate by a factor of 10, the background is subtracted directly

  1. AutoDipole - Automated generation of dipole subtraction terms -

    Science.gov (United States)

    Hasegawa, K.; Moch, S.; Uwer, P.

    2010-10-01

    We present an automated generation of the subtraction terms for next-to-leading order QCD calculations in the Catani-Seymour dipole formalism. For a given scattering process with n external particles our Mathematica package generates all dipole terms, allowing for both massless and massive dipoles. The numerical evaluation of the subtraction terms proceeds with MadGraph, which provides Fortran code for the necessary scattering amplitudes. Checks of the numerical stability are discussed. Program summaryProgram title: AutoDipole Catalogue identifier: AEGO_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEGO_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 138 042 No. of bytes in distributed program, including test data, etc.: 1 117 665 Distribution format: tar.gz Programming language: Mathematica and Fortran Computer: Computers running Mathematica (version 7.0) Operating system: The package should work on every Linux system supported by Mathematica. Detailed tests have been performed on Scientific Linux as supported by DESY and CERN and on openSUSE and Debian. RAM: Depending on the complexity of the problem, recommended at least 128 MB RAM Classification: 11.5 External routines: MadGraph (including HELAS library) available under http://madgraph.hep.uiuc.edu/ or http://madgraph.phys.ucl.ac.be/ or http://madgraph.roma2.infn.it/. A copy of the tar file, MG_ME_SA_V4.4.30, is included in the AutoDipole distribution package. Nature of problem: Computation of next-to-leading order QCD corrections to scattering cross sections, regularization of real emission contributions. Solution method: Catani-Seymour subtraction method for massless and massive partons [1,2]; Numerical evaluation of subtracted matrix elements interfaced to MadGraph [3-5] (stand-alone version) using

  2. Thallium-technetium-subtraction scintigraphy in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Adalet, I.; Hawkins, T.; Clark, F.; Wilkinson, R.

    1994-01-01

    Between 1983 and 1992 thallium-technetium subtraction scintigraphy (TTS) was performed on 74 patients with clinical and biochemical evidence of hyperparathyroidism. Twenty-five of the 53 investigations since 1988 were conducted on patients with renal failure with a suspicion of secondary hyperparathyroidism. In a retrospective study we have evaluated radioisotope scintigraphy for patients with adenoma and for renal failure patients with possible parathyroid hyperplasia. Thirty of 74 patients underwent neck exploration. Scintigraphy detected 17 of 24 parathyroid adenomas (sensitivity 71%). In contrast, in six renal patients who came to operation, scintigraphy localised only 5 of 20 hyperplastic parathyroid glands (sensitivity 25%) and in one renal patient we localised a parathyroid adenoma. A review of the literature shows low detection rates for hyperplasia by TTS to be a common observation. Based on these findings a rational approach is offered for parathyroid localisation in renal patients prior to neck exploration. (orig.)

  3. Suppression Subtractive Hybridization (SSH) and its modifications in microbiological research.

    Science.gov (United States)

    Huang, Xiaowei; Li, Yunxia; Niu, Qiuhong; Zhang, Keqin

    2007-09-01

    Suppression subtractive hybridization (SSH) is an effective approach to identify the genes that vary in expression levels during different biological processes. It is often used in higher eukaryotes to study the molecular regulation in complex pathogenic progress, such as tumorigenesis and other chronic multigene-associated diseases. Because microbes have relatively smaller genomes compared with eukaryotes, aside from the analysis at the mRNA level, SSH as well as its modifications have been further employed to isolate specific chromosomal locus, study genomic diversity related with exceptional bacterial secondary metabolisms or genes with special microbial function. This review introduces the SSH and its associated methods and focus on their applications to detect specific functional genes or DNA markers in microorganisms.

  4. Double-nuclide subtraction scintiscanning of the pancreas

    International Nuclear Information System (INIS)

    Streithoff, E.C.

    1978-01-01

    The paper intends to find out if there is a correlation between clinical pancreas diagnoses and diagnoses by subtraction scintiscanning; furthermore, the findings of scintiscanning are compared with those of radiological and sonographic methods. In order to get a picture of the efficiency of the methods applied, not only their accuracy is determined but also their validity sum and validity product. The best results are achieved here with angiography, ERCP, and sonography. In the case of pancreatic scintiscanning, an optimal result well above the international standard is only obtained for sensitivity. On the basis of these results, the indications for an optimal and useful application of pancreatic scintiscanning are determined. (orig./AJ) [de

  5. [Digital cephalometrics

    NARCIS (Netherlands)

    Ongkosuwito, E.M.; Katsaros, C.; Bodegom, J.C.; Kuijpers-Jagtman, A.M.

    2004-01-01

    There are different methods to produce digital head films and all have advantages and disadvantages. With a digital head film and a computer programme for digital cephalometry an analysis can be performed easily. All existing computer programmes for digital cephalometry use reference values to

  6. Digital squares

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Kim, Chul E

    1988-01-01

    Digital squares are defined and their geometric properties characterized. A linear time algorithm is presented that considers a convex digital region and determines whether or not it is a digital square. The algorithm also determines the range of the values of the parameter set of its preimages. ....... The analysis involves transforming the boundary of a digital region into parameter space of slope and y-intercept......Digital squares are defined and their geometric properties characterized. A linear time algorithm is presented that considers a convex digital region and determines whether or not it is a digital square. The algorithm also determines the range of the values of the parameter set of its preimages...

  7. A comparative study of internal fixation and intermaxillary fixation on bone repair of mandibular fractures through radiographic subtraction.

    Science.gov (United States)

    Queiroz, Christiano Sampaio; Sarmento, Viviane Almeida; de Azevedo, Roberto Almeida; de Oliveira, Thaís Feitosa Leitão; Bastos, Luana Costa

    2014-07-01

    Conventional radiographic evaluation of fracture healing is not a reliable method, because it depends on the examinator's experience and the quality of the exam. Therefore, serial images differing in density, contrast and geometrical projection can lead to a misdiagnosis on the postoperative fracture healing. Even in good quality images, little changes in calcified tissues often can't be visualized, because of its little sensibility and because of the limited human sight. The use of more sensitive and objective methods could increase the accuracy of this evaluation. This study intended to compare, by digitalized panoramic radiography, the mandible fracture healing after two different types of treatment: open reduction with internal fixation (group 1) and closed reduction with intermaxillary fixation (group 2). It was taken three postoperative radiographs (within a week, a month and three months after treatment), which were digitalized (600 dpi, 8 bits) and adjusted in brightness and size in Photoshop software. Then these images were evaluated by digital subtraction in ImageTool software. The results revealed greater areas of new bone formation in the internal fixation group, in all the evaluated times. Thus, open reduction with internal fixation resulted in more rapid fracture healing than closed reduction with intermaxillary fixation. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. INFECTIVE ENDOCARDITIS IN INTRAVENOUS DRUGS ABUSED PATIENT

    Directory of Open Access Journals (Sweden)

    E. Y. Ponomareva

    2011-01-01

    Full Text Available Three-year observation of acute tricuspid infective endocarditis in intravenous drug abused patient: diagnosis, clinical features, visceral lesions, the possibility of cardiac surgery and conservative treatment, outcome.

  9. Intravenous immunoglobulin for chronic inflammatory demyelinating polyradiculoneuropathy

    NARCIS (Netherlands)

    Eftimov, Filip; Winer, John B.; Vermeulen, Marinus; de Haan, Rob; van Schaik, Ivo N.

    2013-01-01

    Chronic inflammatory demyelinating polyradiculoneuropathy (CIDP) causes progressive or relapsing weakness and numbness of the limbs, developing over at least two months. Uncontrolled studies suggest that intravenous immunoglobulin (IVIg) helps. This review was first published in 2002 and has since

  10. Intravenous immunoglobulin for chronic inflammatory demyelinating polyradiculoneuropathy

    NARCIS (Netherlands)

    Eftimov, Filip; Winer, John B.; Vermeulen, Marinus; de Haan, Rob; van Schaik, Ivo N.

    2009-01-01

    Background Chronic inflammatory demyelinating polyradiculoneuropathy (CIDP) causes progressive or relapsing weakness and numbness of the limbs, developing over at least two months. Uncontrolled studies suggest that intravenous immunoglobulin (IVIg) helps. Objectives To review systematically the

  11. Digital broadband linearization of optical links.

    Science.gov (United States)

    Lam, Daniel; Fard, Ali M; Buckley, Brandon; Jalali, Bahram

    2013-02-15

    We present a digital postprocessing linearization technique to efficiently suppress dynamic distortions added to a wideband signal in an analog optical link. Our technique achieves up to 35 dB suppression of intermodulation distortions over multiple octaves of signal bandwidth. In contrast to conventional linearization methods, it does not require excessive analog bandwidth for performing digital correction. This is made possible by regenerating undesired distortions from the captured output, and subtracting it from the distorted digitized signal. Moreover, we experimentally demonstrate a record spurious-free dynamic range of 120 dB·Hz(2/3) over a 6 GHz electrical signal bandwidth. While our digital broadband linearization technique advances state-of-the-art optical links, it can also be applied to other nonlinear dynamic systems.

  12. A subtraction scheme for computing QCD jet cross sections at NNLO. Integrating the iterated singly-unresolved subtraction terms

    Energy Technology Data Exchange (ETDEWEB)

    Bolzoni, Paolo [Hamburg Univ. (Germany). II. Inst. fuer Theoretische Physik; Somogyi, Gabor [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Trocsanyi, Zoltan [Debrecen Univ. (Hungary); Hungarian Academy of Sciences, Debrecen (Hungary). Inst. of Nuclear Research

    2010-11-15

    We perform the integration of all iterated singly-unresolved subtraction terms over the two-particle factorized phase space. We also sum over the unresolved parton flavours. The final result can be written as a convolution (in colour space) of the Born cross section and an insertion operator. We spell out the insertion operator in terms of 24 basic integrals that are defined explicitly. We compute the coefficients of the Laurent-expansion of these integrals in two different ways, with the method of Mellin-Barnes representations and sector decomposition. Finally, we present the Laurentexpansion of the full insertion operator for the specific examples of electron-positron annihilation into two and three jets. (orig.)

  13. Putting Essential Understanding of Addition and Subtraction into Practice: Pre-K-2

    Science.gov (United States)

    Caldwell, Janet H.; Kobett, Beth; Karp, Karen

    2014-01-01

    Do your students have the incorrect idea that addition "makes numbers bigger" and subtraction "makes numbers smaller"? Do they believe that subtraction is always "taking away"? What tasks can you offer--what questions can you ask--to determine what your students know or don't know--and move them forward in their…

  14. A Feature Subtraction Method for Image Based Kinship Verification under Uncontrolled Environments

    DEFF Research Database (Denmark)

    Duan, Xiaodong; Tan, Zheng-Hua

    2015-01-01

    the feature distance between face image pairs with kinship and maximize the distance between non-kinship pairs. Based on the subtracted feature, the verification is realized through a simple Gaussian based distance comparison method. Experiments on two public databases show that the feature subtraction method...

  15. Intravenous iron-containing products: EMA procrastination.

    Science.gov (United States)

    2014-07-01

    A European reassessment has led to identical changes in the summaries of product characteristics (SPCs) for all intravenous iron-containing products: the risk of serious adverse effects is now highlighted, underlining the fact that intravenous iron-containing products should only be used when the benefits clearly outweigh the harms. Unfortunately, iron dextran still remains on the market despite a higher risk of hypersensitivity reactions than with iron sucrose.

  16. Contrast medium extravasation in intravenous urography

    International Nuclear Information System (INIS)

    Tosch, U.; Becker-Gaab, C.; Hahn, D.

    1984-01-01

    Aetiology and diagnostic procedure of calyceal fornix rupture during intravenous urography are discussed. In the literature the fornix rupture is discribed as a spontaneous event - not so in the four cases presented. In two cases a sudden increase in intrapelvic pressure was due to an ureteric calculus, in the other cases an obstruction of the ureter was secondary to neoplasm. It is recommended to perform a CT as soon as a contrastmedium extravasation in intravenous urography is diagnosed. (orig.) [de

  17. Contrast medium extravasation in intravenous urography

    Energy Technology Data Exchange (ETDEWEB)

    Tosch, U.; Becker-Gaab, C.; Hahn, D.

    1984-09-01

    Aetiology and diagnostic procedure of calyceal fornix rupture during intravenous urography are discussed. In the literature the fornix rupture is discribed as a spontaneous event - not so in the four cases presented. In two cases a sudden increase in intrapelvic pressure was due to an ureteric calculus, in the other cases an obstruction of the ureter was secondary to neoplasm. It is recommended to perform a CT as soon as a contrast medium extravasation in intravenous urography is diagnosed.

  18. A posteriori registration and subtraction of panoramic compared with intraoral radiography.

    Science.gov (United States)

    Deserno, Thomas M; Rangarajan, Janaki Raman; Hoffmann, Jens; Brägger, Urs; Mericske-Stern, Regina; Enkling, Norbert

    2009-08-01

    To demonstrate the feasibility of panoramic image subtraction for implant assessment. Three titanium implants were inserted into a fresh pig mandible. One intraoral and 2 panoramic images were obtained at baseline and after each of 6 incremental (0.3, 0.6, 1.0, 1.5, 2.0, 2.5 mm) removals of bone. For each incremental removal of bone, the mandible was removed from and replaced in the holding device. Images representing incremental bone removals were registered by computer with the baseline images and subtracted. Assessment of the subtraction images was based on visual inspection and analysis of structured noise. Incremental bone removals were more visible in intraoral than in panoramic subtraction images; however, computer-based registration of panoramic images reduced the structured noise and enhanced the visibility of incremental removals. The feasibility of panoramic image subtraction for implant assessment was demonstrated.

  19. Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD/CAM systems.

    Science.gov (United States)

    Kim, Dong-Yeon; Kim, Eo-Bin; Kim, Hae-Young; Kim, Ji-Hwan; Kim, Woong-Chul

    2017-12-01

    To evaluate the fit of a three-unit metal framework of fixed dental prostheses made by subtractive and additive manufacturing. One master model of metal was fabricated. Twenty silicone impressions were made on the master die, working die of 10 poured with Type 4 stone, and working die of 10 made of scannable stone. Ten three-unit wax frameworks were fabricated by wax-up from Type IV working die. Stereolithography files of 10 three-unit frameworks were obtained using a model scanner and three-dimensional design software on a scannable working die. The three-unit wax framework was fabricated using subtractive manufacturing (SM) by applying the prepared stereolithography file, and the resin framework was fabricated by additive manufacturing (AM); both used metal alloy castings for metal frameworks. Marginal and internal gap were measured using silicone replica technique and digital microscope. Measurement data were analyzed by Kruskal-Wallis H test and Mann-Whitney U-test (α=.05). The lowest and highest gaps between premolar and molar margins were in the SM group and the AM group, respectively. There was a statistically significant difference in the marginal gap among the 3 groups ( P unit metal frameworks made by subtractive manufacturing are clinically applicable. However, additive manufacturing requires more research to be applied clinically.

  20. Digital Culture and Digital Library

    Directory of Open Access Journals (Sweden)

    Yalçın Yalçınkaya

    2016-12-01

    Full Text Available In this study; digital culture and digital library which have a vital connection with each other are examined together. The content of the research consists of the interaction of culture, information, digital culture, intellectual technologies, and digital library concepts. The study is an entry work to integrity of digital culture and digital library theories and aims to expand the symmetry. The purpose of the study is to emphasize the relation between the digital culture and digital library theories acting intersection of the subjects that are examined. Also the perspective of the study is based on examining the literature and analytical evaluation in both studies (digital culture and digital library. Within this context, the methodology of the study is essentially descriptive and has an attribute for the transmission and synthesis of distributed findings produced in the field of the research. According to the findings of the study results, digital culture is an inclusive term that describes the effects of intellectual technologies in the field of information and communication. Information becomes energy and the spectrum of the information is expanding in the vertical rise through the digital culture. In this context, the digital library appears as a new living space of a new environment. In essence, the digital library is information-oriented; has intellectual technology support and digital platform; is in a digital format; combines information resources and tools in relationship/communication/cooperation by connectedness, and also it is the dynamic face of the digital culture in time and space independence. Resolved with the study is that the digital libraries are active and effective in the formation of global knowing and/or mass wisdom in the process of digital culture.

  1. Intravenous fluids in acute decompensated heart failure.

    Science.gov (United States)

    Bikdeli, Behnood; Strait, Kelly M; Dharmarajan, Kumar; Li, Shu-Xia; Mody, Purav; Partovian, Chohreh; Coca, Steven G; Kim, Nancy; Horwitz, Leora I; Testani, Jeffrey M; Krumholz, Harlan M

    2015-02-01

    This study sought to determine the use of intravenous fluids in the early care of patients with acute decompensated heart failure (HF) who are treated with loop diuretics. Intravenous fluids are routinely provided to many hospitalized patients. We conducted a retrospective cohort study of patients admitted with HF to 346 hospitals from 2009 to 2010. We assessed the use of intravenous fluids during the first 2 days of hospitalization. We determined the frequency of adverse in-hospital outcomes. We assessed variation in the use of intravenous fluids across hospitals and patient groups. Among 131,430 hospitalizations for HF, 13,806 (11%) were in patients treated with intravenous fluids during the first 2 days. The median volume of administered fluid was 1,000 ml (interquartile range: 1,000 to 2,000 ml), and the most commonly used fluids were normal saline (80%) and half-normal saline (12%). Demographic characteristics and comorbidities were similar in hospitalizations in which patients did and did not receive fluids. Patients who were treated with intravenous fluids had higher rates of subsequent critical care admission (5.7% vs. 3.8%; p fluid treatment varied widely across hospitals (range: 0% to 71%; median: 12.5%). Many patients who are hospitalized with HF and receive diuretics also receive intravenous fluids during their early inpatient care, and the proportion varies among hospitals. Such practice is associated with worse outcomes and warrants further investigation. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Fuzzy subtractive clustering based prediction model for brand association analysis

    Directory of Open Access Journals (Sweden)

    Widodo Imam Djati

    2018-01-01

    Full Text Available The brand is one of the crucial elements that determine the success of a product. Consumers in determining the choice of a product will always consider product attributes (such as features, shape, and color, however consumers are also considering the brand. Brand will guide someone to associate a product with specific attributes and qualities. This study was designed to identify the product attributes and predict brand performance with those attributes. A survey was run to obtain the attributes affecting the brand. Subtractive Fuzzy Clustering was used to classify and predict product brand association based aspects of the product under investigation. The result indicates that the five attributes namely shape, ease, image, quality and price can be used to classify and predict the brand. Training step gives best FSC model with radii (ra = 0.1. It develops 70 clusters/rules with MSE (Training is 9.7093e-016. By using 14 data testing, the model can predict brand very well (close to the target with MSE is 0.6005 and its’ accuracy rate is 71%.

  3. Identification of formaldehyde-responsive genes by suppression subtractive hybridization

    International Nuclear Information System (INIS)

    Lee, Min-Ho; Kim, Young-Ae; Na, Tae-Young; Kim, Sung-Hye; Shin, Young Kee; Lee, Byung-Hoon; Shin, Ho-Sang; Lee, Mi-Ock

    2008-01-01

    Formaldehyde is frequently used in indoor household and occupational environments. Inhalation of formaldehyde invokes an inflammatory response, including a variety of allergic signs and symptoms. Therefore, formaldehyde has been considered as the most prevalent cause of sick building syndrome, which has become a major social problem, especially in developing urban areas. Further formaldehyde is classified as a genotoxicant in the respiratory tract of rats and humans. To better understand the molecular mechanisms involved in formaldehyde intoxication, we sought differentially regulated genes by formaldehyde exposure to Hs 680.Tr human trachea cells, using polymerase chain reaction (PCR)-based suppression subtractive hybridization. We identified 27 different formaldehyde-inducible genes, including those coding for the major histocompatibility complex, class IA, calcyclin, glutathione S-transferase pi, mouse double minute 2 (MDM2), platelet-derived growth factor receptor alpha, and which are known to be associated with cell proliferation and differentiation, immunity and inflammation, and detoxification. Induction of these genes by formaldehyde treatment was confirmed by reverse transcription PCR and western blot analysis. Further, the expression of calcyclin, glutathione S-transferase pi, PDGFRA and MDM2 were significantly induced in the tracheal epithelium of Sprague Dawley rats after formaldehyde inhalation. Our results suggest that the elevated levels of these genes may be associated with the formaldehyde-induced toxicity, and that they deserve evaluation as potential biomarkers for formaldehyde intoxication

  4. Behavioural evidence for sex differences in the overlap between subtraction and multiplication.

    Science.gov (United States)

    Pletzer, Belinda; Moeller, Korbinian; Scheuringer, Andrea; Domahs, Frank; Kerschbaum, Hubert H; Nuerk, Hans-Christoph

    2016-05-01

    The present study aims to identify factors that may influence the dissociability of number magnitude processing and arithmetic fact retrieval at the behavioural level. To that end, we assessed both subtraction and multiplication performance in a within-subject approach and evaluated the interdependence of unit-decade integration measures on the one hand as well as sex differences in the interdependence of performance measures on the other hand. We found that subtraction items requiring borrowing (e.g. 53-29 = 24, 3 3), thereby demonstrating a borrowing effect, which has been suggested as a measure of unit-decade integration in subtraction. Furthermore, we observed that multiplication items with decade-consistent distractors (e.g. 6 × 4 = 28 instead of 24) are more error prone that multiplication items with decade-inconsistent distractors (e.g. 6 × 4 = 30 instead of 24), thereby demonstrating a decade-consistency effect, which has been suggested as a measure of unit-decade integration in simple multiplication. However, the borrowing effect in subtraction was not correlated with the effect of decade consistency in simple multiplication in either men or women. This indicates that unit-decade integration arises from different systems in subtraction and multiplication. Nevertheless, men outperformed women not only in subtraction, but also in multiplication. Furthermore, subtraction and multiplication performance on correct solution probes were correlated in women, but unrelated in men. Thus, the view of differential systems for number magnitude processing and arithmetic fact retrieval may not be universal across sexes.

  5. Tomosynthesis and contrast-enhanced digital mammography: recent advances in digital mammography

    International Nuclear Information System (INIS)

    Diekmann, Felix; Bick, Ulrich

    2007-01-01

    Digital mammography is more and more replacing conventional mammography. Initial concerns about an inferior image quality of digital mammography have been largely overcome and recent studies even show digital mammography to be superior in women with dense breasts, while at the same time reducing radiation exposure. Nevertheless, an important limitation of digital mammography remains: namely, the fact that summation may obscure lesions in dense breast tissue. However, digital mammography offers the option of so-called advanced applications, and two of these, contrast-enhanced mammography and tomosynthesis, are promising candidates for improving the detection of breast lesions otherwise obscured by the summation of dense tissue. Two techniques of contrast-enhanced mammography are available: temporal subtraction of images acquired before and after contrast administration and the so-called dual-energy technique, which means that pairs of low/high-energy images acquired after contrast administration are subtracted. Tomosynthesis on the other hand provides three-dimensional information on the breast. The images are acquired with different angulations of the X-ray tube while the object or detector is static. Various reconstruction algorithms can then be applied to the set of typically nine to 28 source images to reconstruct 1-mm slices with a reduced risk of obscuring pathology. Combinations of both advanced applications have only been investigated in individual experimental studies; more advanced software algorithms and CAD systems are still in their infancy and have only undergone preliminary clinical evaluation. (orig.)

  6. Digital Tectonics

    DEFF Research Database (Denmark)

    Christiansen, Karl; Borup, Ruben; Søndergaard, Asbjørn

    2014-01-01

    Digital Tectonics treats the architectonical possibilities in digital generation of form and production. The publication is the first volume of a series, in which aspects of the strategic focus areas of the Aarhus School of Architecture will be disseminated.......Digital Tectonics treats the architectonical possibilities in digital generation of form and production. The publication is the first volume of a series, in which aspects of the strategic focus areas of the Aarhus School of Architecture will be disseminated....

  7. Digital skrivedidaktik

    DEFF Research Database (Denmark)

    Digital skrivedidaktik består af to dele. Første del præsenterer teori om skrivekompetence og digital skrivning. Digital skrivning er karakteriseret ved at tekster skrives på computer og med digitale værktøjer, hvilket ændrer skrivningens traditionelle praksis, produkt og processer. Hvad er digital...... om elevens skriveproces) og Blogskrivning (der styrker eleverne i at bruge blogs i undervisningen)....

  8. Ending up with Less: The Role of Working Memory in Solving Simple Subtraction Problems with Positive and Negative Answers

    Science.gov (United States)

    Robert, Nicole D.; LeFevre, Jo-Anne

    2013-01-01

    Does solving subtraction problems with negative answers (e.g., 5-14) require different cognitive processes than solving problems with positive answers (e.g., 14-5)? In a dual-task experiment, young adults (N=39) combined subtraction with two working memory tasks, verbal memory and visual-spatial memory. All of the subtraction problems required…

  9. What´s cheapest, intravenous iron sucrose- or intravenous iron carboxymaltose treatment in IBD patients?

    DEFF Research Database (Denmark)

    Bager, Palle; Dahlerup, Jens Frederik

      What´s cheapest, intravenous iron sucrose- or intravenous iron carboxymaltose treatment in IBD patients? It dependent on the economic evaluation perspective!   Aim: To evaluate the health care cost for intravenous iron sucrose (Venofer®, Vifor) and intravenous iron carboxymaltose (Ferinject......-cost per mg iron is for iron carboxymaltose approximately double the cost of iron sucrose.   Patients and Methods: Data related to 111 IBD-patients treated with intravenous iron at Aarhus University Hospital from August 2005 until October 2009 was used for the economic evaluation. Analysis included......, utensils and ½ hour spend by a nurse per visit; showed approximately 150€ extra cost per 1000 mg Fe++ administrated, if iron carboxymaltose was chosen. In contrast the CEA including both BIA-values and patient-related costs (transportation and lost income) showed iron carboxymaltose to be more cost...

  10. Digital book architecture on google platform: an exploratory study

    Directory of Open Access Journals (Sweden)

    Stella Moreira Dourado

    2012-08-01

    Full Text Available This paper analyses the architecture of the digital book using indicators applied to the evaluation of the printed book and indicators applied to evaluate the performance of digital artifacts. Publishers of digital books seem interested in preserving the characteristics of the printed book in the electronic environment, adopting standards that attempt to “soften” the transition to digital media. The comparative analysis of Google Books platform was conducted using a synoptic table containing the features likely to compare between the digital and the printed book. The authors have concluded that the digital books on Google Books platform add little value to the characteristics of the printed book, subtracting from them, at the same time, some of their distinguishing features, such as portability.

  11. DIGITAL FORGERY

    OpenAIRE

    Sarhan M. Musa1

    2017-01-01

    Forgery is the criminal act that provides misleading information about a product or service. It is the process of making, adapting, or imitating documents or objects with the intent to deceive. Digital forgery (or digital tampering) is the process of manipulating documents or images for the intent of financial, social or political gain. This paper provides a brief introduction to the digital forgery.

  12. Digital Citizenship

    Science.gov (United States)

    Isman, Aytekin; Canan Gungoren, Ozlem

    2014-01-01

    Era in which we live is known and referred as digital age.In this age technology is rapidly changed and developed. In light of these technological advances in 21st century, schools have the responsibility of training "digital citizen" as well as a good citizen. Digital citizens must have extensive skills, knowledge, Internet and …

  13. A Wireless FSCV Monitoring IC With Analog Background Subtraction and UWB Telemetry.

    Science.gov (United States)

    Dorta-Quiñones, Carlos I; Wang, Xiao Y; Dokania, Rajeev K; Gailey, Alycia; Lindau, Manfred; Apsel, Alyssa B

    2016-04-01

    A 30-μW wireless fast-scan cyclic voltammetry monitoring integrated circuit for ultra-wideband (UWB) transmission of dopamine release events in freely-behaving small animals is presented. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus standard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission for low data rates. The 1.5- mm(2) chip, which was fabricated in 65-nm CMOS technology, consists of a low-noise potentiostat frontend, a two-step analog-to-digital converter (ADC), and an impulse-radio UWB transmitter (TX). The duty-cycled frontend and ADC/UWB-TX blocks draw 4 μA and 15 μA from 3-V and 1.2-V supplies, respectively. The chip achieves an input-referred current noise of 92 pA(rms) and an input current range of ±430 nA at a conversion rate of 10 kHz. The packaged device operates from a 3-V coin-cell battery, measures 4.7 × 1.9 cm(2), weighs 4.3 g (including the battery and antenna), and can be carried by small animals. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 1 μM with a carbon-fiber microelectrode (CFM) using 300-V/s FSCV.

  14. A Wireless FSCV Monitoring IC with Analog Background Subtraction and UWB Telemetry

    Science.gov (United States)

    Dorta-Quiñones, Carlos I.; Wang, Xiao Y.; Dokania, Rajeev K.; Gailey, Alycia; Lindau, Manfred; Apsel, Alyssa B.

    2015-01-01

    A 30-μW wireless fast-scan cyclic voltammetry monitoring integrated circuit for ultra-wideband (UWB) transmission of dopamine release events in freely-behaving small animals is presented. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus standard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission for low data rates. The 1.5-mm2 chip, which was fabricated in 65-nm CMOS technology, consists of a low-noise potentiostat frontend, a two-step analog-to-digital converter (ADC), and an impulse-radio UWB transmitter (TX). The duty-cycled frontend and ADC/UWB-TX blocks draw 4 μA and 15 μA from 3-V and 1.2-V supplies, respectively. The chip achieves an input-referred current noise of 92 pArms and an input current range of ±430 nA at a conversion rate of 10 kHz. The packaged device operates from a 3-V coin-cell battery, measures 4.7 × 1.9 cm2, weighs 4.3 g (including the battery and antenna), and can be carried by small animals. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 1 μM with a carbon-fiber microelectrode (CFM) using 300-V/s FSCV. PMID:26057983

  15. Digital preservation

    CERN Document Server

    Deegan, Marilyn

    2013-01-01

    Digital preservation is an issue of huge importance to the library and information profession right now. With the widescale adoption of the internet and the rise of the world wide web, the world has been overwhelmed by digital information. Digital data is being produced on a massive scale by individuals and institutions: some of it is born, lives and dies only in digital form, and it is the potential death of this data, with its impact on the preservation of culture, that is the concern of this book. So how can information professionals try to remedy this? Digital preservation is a complex iss

  16. Optimized intravenous flat detector CT for non-invasive visualization of intracranial stents: first results

    International Nuclear Information System (INIS)

    Struffert, Tobias; Kloska, Stephan; Engelhorn, Tobias; Ott, Sabine; Doelken, Marc; Saake, Marc; Doerfler, Arnd; Deuerling-Zheng, Yu.; Koehrmann, Martin

    2011-01-01

    As stents for treating intracranial atherosclerotic stenosis may develop in-stent re-stenosis (ISR) in up to 30%, follow-up imaging is mandatory. Residual stenosis (RS) is not rare. We evaluated an optimised Flat Detector CT protocol with intravenous contrast material application (i.v. FD-CTA) for non-invasive follow-up. In 12 patients with intracranial stents, follow-up imaging was performed using i.v. FD-CTA. MPR, subtracted MIP and VRT reconstructions were used to correlate to intra-arterial angiography (DSA). Two neuroradiologists evaluated the images in anonymous consensus reading and calculated the ISR or RS. Correlation coefficients and a Wilcoxon test were used for statistical analysis. In 4 patients, no stenosis was detected. In 6 patients RS and in two cases ISR by intima hyperplasia perfectly visible on MPR reconstructions of i.v. FD-CTA were detected. Wilcoxon's test showed no significant differences between the methods (p > 0.05). We found a high correlation with coefficients of the pairs DSA/ FD-CT MIP r = 0.91, DSA/ FD-CT MPR r = 0.82 and FD-CT MIP/ FD-CT MPR r = 0.8. Intravenous FD-CTA could clearly visualise the stent and the lumen, allowing ISR or RS to be recognised. FD-CTA provides a non-invasive depiction of intracranial stents and might replace DSA for non-invasive follow-up imaging. (orig.)

  17. A phase I trial of intravenous catumaxomab

    DEFF Research Database (Denmark)

    Mau-Sørensen, Morten; Dittrich, Christian; Dienstmann, Rodrigo

    2015-01-01

    design in epithelial cancers with known EpCAM expression. The dose-limiting toxicity (DLT) period consisted of 4 weeks, with weekly intravenous administration of catumaxomab. Key DLTs were ≥grade 3 optimally treated non-hematological toxicity; ≥grade 3 infusion-related reactions refractory to supportive....... A reversible decrease in liver function test (prothrombin time) at the 7-µg dose level was considered a DLT. The first patient at 10 µg experienced a fatal hepatic failure related to catumaxomab that led to the termination of the study. CONCLUSIONS: The MTD of weekly intravenous catumaxomab was 7 µg. Major...

  18. Intravenous polyclonal human immunoglobulins in multiple sclerosis

    DEFF Research Database (Denmark)

    Sørensen, Per Soelberg

    2008-01-01

    Intravenous immunoglobulin (IVIG) is an established therapy for demyelinating diseases of the peripheral nervous system. IVIG exerts a number of effects that may be beneficial in multiple sclerosis (MS). Four double-blind IVIG trials have been performed in relapsing-remitting MS. A meta-analysis ......Intravenous immunoglobulin (IVIG) is an established therapy for demyelinating diseases of the peripheral nervous system. IVIG exerts a number of effects that may be beneficial in multiple sclerosis (MS). Four double-blind IVIG trials have been performed in relapsing-remitting MS. A meta...

  19. Managing digitally formatted diagnostic image data

    International Nuclear Information System (INIS)

    Templeton, A.W.; Dwyer, S.J.

    1985-01-01

    Diagnostic radiologists are very comfortable using analog radiographic film and interpreting its recorded images. To improve patient care, the radiologist has sought the finest quality radiographic film for use with the best radiographic imaging systems. The proper choice and use of x-ray tubes, generators, film-screen combinations, and contrast media has occupied the professional attention of the radiologist since the inception of radiology. Image quality can be significantly improved with digitally formatted diagnostic imaging systems by providing dynamic ranges in excess of those possible with analog x-ray films. In a CT scanner, the digital acquisition and reconstruction system can obtain a dynamic range (contrast resolution) of 10,000 to 1. Digital subtraction angiography systems achieve 10-bit dynamic ranges for each of the acquired television frames. Increases in the dynamic ranges of the various imaging modalities have been coupled with improved spatial resolution. A digitally formatted image is a two-dimensional, numerical array of discrete image elements. Each picture element is called a pixel. Each pixel has a discrete size. Figure 15.1 illustrates a digitally formatted image depicting the spatial resolution, array size, and quantization or numerical range of the pixel values. Currently, 512 x 512 image arrays are standard. Development of 1024 x 1024 digital arrays are underway. Significant improvements have also been achieved in the rates at which digital diagnostic imaging data can be acquired, manipulated, and archived

  20. A temporal subtraction method for thoracic CT images based on generalized gradient vector flow

    International Nuclear Information System (INIS)

    Miyake, Noriaki; Kim, H.; Maeda, Shinya; Itai, Yoshinori; Tan, J.K.; Ishikawa, Seiji; Katsuragawa, Shigehiko

    2010-01-01

    A temporal subtraction image, which is obtained by subtraction of a previous image from a current one, can be used for enhancing interval changes (such as formation of new lesions and changes in existing abnormalities) on medical images by removing most of the normal structures. If image registration is incorrect, not only the interval changes but also the normal structures would be appeared as some artifacts on the temporal subtraction image. In a temporal subtraction technique for 2-D X-ray image, the effectiveness is shown through a lot of clinical evaluation experiments, and practical use is advancing. Moreover, the MDCT (Multi-Detector row Computed Tomography) can easily introduced on medical field, the development of a temporal subtraction for thoracic CT Images is expected. In our study, a temporal subtraction technique for thoracic CT Images is developed. As the technique, the vector fields are described by use of GGVF (Generalized Gradient Vector Flow) from the previous and current CT images. Afterwards, VOI (Volume of Interest) are set up on the previous and current CT image pairs. The shift vectors are calculated by using nearest neighbor matching of the vector fields in these VOIs. The search kernel on previous CT image is set up from the obtained shift vector. The previous CT voxel which resemble standard the current voxel is detected by voxel value and vector of the GGVF in the kernel. And, the previous CT image is transformed to the same coordinate of standard voxel. Finally, temporal subtraction image is made by subtraction of a warping image from a current one. To verify the proposal method, the result of application to 7 cases and the effectiveness are described. (author)

  1. Subtraction of random coincidences in γ-ray spectroscopy: A new approach

    International Nuclear Information System (INIS)

    Pattabiraman, N.S.; Ghugre, S.S.; Basu, S.K.; Garg, U.; Ray, S.; Sinha, A.K.; Zhu, S.

    2006-01-01

    A new analytical method for estimation and subsequent subtraction of random coincidences has been developed. It utilizes the knowledge of the counts in the main diagonal of a background-subtracted symmetric data set for the estimation of the events originating from random coincidences. This procedure has been successfully applied to several data sets. It could be a valuable tool for low-fold data sets, especially for low-cross-section events

  2. Administration and monitoring of intravenous anesthetics

    NARCIS (Netherlands)

    Sahinovic, Marko M.; Absalom, Anthony R.; Struys, Michel M. R. F.

    2010-01-01

    Purpose of review The importance of accuracy in controlling the dose-response relation for intravenous anesthetics is directly related to the importance of optimizing the efficacy and quality of anesthesia while minimizing adverse drug effects. Therefore, it is important to measure and control all

  3. Intravenous immunoglobulin treatment for secondary recurrent miscarriage

    DEFF Research Database (Denmark)

    Christiansen, O B; Larsen, E C; Egerup, P

    2015-01-01

    OBJECTIVE: To determine whether infusions with intravenous immunoglobulin (IVIg) during early pregnancy increase live birth rate in women with secondary recurrent miscarriage compared with placebo. DESIGN: A single-centre, randomised, double-blind, placebo-controlled trial. SETTING: A tertiary...

  4. Intravenous iron supplementation in children on hemodialysis.

    NARCIS (Netherlands)

    Leijn, E.; Monnens, L.A.H.; Cornelissen, E.A.M.

    2004-01-01

    BACKGROUND: Children with end-stage renal disease (ESRD) on hemodialysis (HD) are often absolute or functional iron deficient. There is little experience in treating these children with intravenous (i.v.) iron-sucrose. In this prospective study, different i.v. iron-sucrose doses were tested in

  5. Intravenous and intramuscular magnesium sulphate regimens in ...

    African Journals Online (AJOL)

    1993-09-03

    Sep 3, 1993 ... parenterally, usually according to one of two popular regimens: the intramuscular (IM) regimen introduced by. Pritchard' and a continuous intravenous (IV) infusion described by Zuspan! Sibai et a/.3 have reported that lower serum magnesium values are achieved with Zuspan's regimen (maintenance dose ...

  6. Clinical Evaluation of Ciprofloxacin Intravenous Preparation ...

    African Journals Online (AJOL)

    The most common site of bacteria infection in humans is the urinary tract. For nosocomial infections it is the catheterized urinary tract. Compromised immune responses in hospitalized patients contribute to the difficulties encountered in treating their infections. In these patients, administration of intravenous antibiotic is ...

  7. A Comparison of Prophylactic Intravenous Glycopyrrolate and ...

    African Journals Online (AJOL)

    Ephedrine is gradually falling out of favour because of the associated tachyarrhythmia and foetal acidosis. This study compared the effect of preoperative administration of intravenous glycopyrrolate and ephedrine on spinal induced maternal hypotension. Patients and Methods: Fifty patients scheduled for elective C/S were ...

  8. Comparative Evaluation of Ultrasonography and Intravenous ...

    African Journals Online (AJOL)

    Background: Renal ultrasonography an easily available procedure was compared to intravenous urogram (IVU) to determine its suitability as an alternative to the latter, which is a relatively invasive test for demonstrating hydronephrosis/ or ureteric obstruction in cervical cancer staging. Study design: Thirty five histologically ...

  9. Intravenous voriconazole after toxic oral administration

    NARCIS (Netherlands)

    Alffenaar, J.W.C.; Van Assen, S.; De Monchy, J.G.R.; Uges, D.R.A.; Kosterink, J.G.W.; Van Der Werf, T.S.

    In a male patient with rhinocerebral invasive aspergillosis, prolonged high-dosage oral administration of voriconazole led to hepatotoxicity combined with a severe cutaneous reaction while intravenous administration in the same patient did not. High concentrations in the portal blood precipitate

  10. Intravenous paracetamol overdose in a paediatric patient

    NARCIS (Netherlands)

    Broeks, Ilse J.; Van Roon, Eric N.; Van Pinxteren-Nagler, Evelyn; De Vries, Tjalling W.

    2013-01-01

    BACKGROUND: Paracetamol is a widely used drug in children. In therapeutic doses, paracetamol has an excellent safety profile. Since the introduction of the intravenous form in 2004, only three reports of accidental overdose in children have been published. The low number probably is due to

  11. Intramuscular compared to intravenous midazolam for paediatric ...

    African Journals Online (AJOL)

    Background: Sedation in children remains a controversial issue in emergency departments (ED). Midazolam, as a benzodiazepine is widely used for procedural sedation among paediatrics. We compared the effectiveness and safety of two forms of midazolam prescription; intramuscular (IM) and intravenous (IV). Patients ...

  12. Intravenous platelet blockade with cangrelor during PCI

    NARCIS (Netherlands)

    Bhatt, Deepak L.; Lincoff, A. Michael; Gibson, C. Michael; Stone, Gregg W.; McNulty, Steven; Montalescot, Gilles; Kleiman, Neal S.; Goodman, Shaun G.; White, Harvey D.; Mahaffey, Kenneth W.; Pollack, Charles V.; Manoukian, Steven V.; Widimsky, Petr; Chew, Derek P.; Cura, Fernando; Manukov, Ivan; Tousek, Frantisek; Jafar, M. Zubair; Arneja, Jaspal; Skerjanec, Simona; Harrington, Robert A.; Bhatt, D. L.; Harrington, R. A.; Lincoff, A. M.; Pollack, C. V.; Gibson, C. M.; Stone, G. W.; Mahaffey, K. W.; Kleiman, N. S.; Montalescot, G.; White, H. D.; Goodman, S. G.; Greenbaum, A.; Simon, D.; Lee, D.; Feit, F.; Dauerman, H.; Gurbel, P.; Berger, P.; Makkar, R.; Becker, R. C.; Manoukian, S.; Jorgova, J.; Chew, D. P.; Storey, R.; Desmet, W.; Cura, F.; Herrmann, H.; Rizik, D.; DeServi, S.; Huber, K.; Jukema, W. J.; Knopf, W.; Steg, P. G.; Schunkert, H.; Widimsky, P.; Betriu, A.; Aylward, P.; Polonestsky, L.; Lima, V.; Kobulia, B.; Navickas, R.; Gasior, Z.; Vasilieva, E.; Bennett, J. M.; Kraiz, I.; Van de Werf, F.; Faxon, D.; Ohman, E. M.; Tijssen, J. G. P.; Verheugt, F.; Weaver, W. D.; Califf, R. M.; Mehta, C.; Hamm, C. W.; Pepine, C. J.; Ware, J.; Wilson, M.; Gorham, C.; Maran, A.; McNulty, S.; Fasteson, D.; Ryan, G.; Bradsher, J.; Connolly, P.; Mehta, R.; Leonardi, S.; Brennan, M.; Patel, M.; Petersen, J.; Bushnel, C.; Jolicoeur, M.; Chan, M.; Dowd, L.; Skinner, P.; Lawrence, G.; Jordon, M.; Dickerson, S.; Meyer, M.; Hartford, S.; Garcia Escudero, Alejandro; Poy, Carlos; Miceli, Miguel; Pocovi, Antonio; Londero, Hugo; Baccaro, Jorge; Polonetsky, Leonid; Karotkin, Aliaksey; Shubau, Leanid; Maffini, Eduardo; Machado, Bruno; Airton, José; Lima, Valter; Martinez Filho, Eulogio; Herdy, Arthur; Tumelero, Rogerio; Precoma, Dalton; Botelho, Roberto; Saad, Jamil; Jatene, Jose; Vilas-Boas, Fabio; Godinho, Antonio; Perin, Marco; Caramori, Paulo; Castro, Iran; Grigorov, Mladen; Milkov, Plamen; Jorgova, Julia; Georgiev, Svetoslav; Rifai, Nizar; Doganov, Alexander; Petrov, Ivo; Hui, William; Lazzam, Charles; Reeves, Francois; Tanguay, Jean-Francois; Richter, Marek; Klimsa, Zdenek; Padour, Michal; Mrozek, Jan; Branny, Marian; Coufal, Zdenek; Simek, Stanislav; Rozsival, Vladimir; Pleva, Leos; Stasek, Josef; Kala, Petr; Groch, Ladislav; Kocka, Viktor; Shaburishvili, Tamaz; Khintibidze, Irakli; Chapidze, Gulnara; Mamatsashvili, Merab; Mohanan, Padinhare; Jain, Rajesh; Parikh, Keyur; Patel, Tejas; Kumar, Sampath; Mehta, Ashwani; Banker, Darshan; Krishna, Lanka; Gadkari, Milind; Joshi, Hasit; Hiremath, Shirish; Grinius, Virgilijus; Norkiene, Sigute; Petrauskiene, Birute; Michels, Rolf; Tjon, Melvin; de Swart, Hans; de Winter, Robbert; White, Harvey; Devlin, Gerard; Abernethey, Malcolm; Osiev, Alexander; Linev, Kirill; Kalinina, Svetlana; Baum, Svetlana; Kosmachova, Elena; Shogenov, Zaur; Markov, Valentin; Boldueva, Svetlana; Barbarash, Olga; Kostenko, Victor; Vasilieva, Elena; Gruzdev, Aleksey; Lusov, Victor; Dovgalevsky, Pavel; Azarin, Oleg; Chernov, Sergey; Smolenskaya, Olga; Duda, Alexey; Fridrich, Viliam; Hranai, Marian; Studencan, Martin; Kurray, Peter; Bennett, John; Blomerus, Pieter; Disler, Laurence; Engelbrecht, Johannes; Klug, Eric; Routier, Robert; Venter, Tjaart; van der Merwe, Nico; Becker, Anthony; Cha, Kwang-Soo; Lee, Seung-Hwan; Han, Sang-Jin; Youn, Tae Jin; Hur, Seung-Ho; Seo, Hong Seog; Park, Hun-Sik; Rhim, Chong-Yun; Pyun, Wook-Bum; Choe, Hyunmin; Jeong, Myung-Ho; Park, Jong-Seon; Shin, Eak-Kyun; Hernández, Felipe; Figueras, Jaume; Hernández, Rosana; López-Minguez, José Ramón; González Juanatey, José Ramón; Palop, Ramón López; Galeote, Guillermo; Chamnarnphol, Noppadol; Buddhari, Wacin; Sansanayudh, Nakarin; Kuanprasert, Srun; Penny, William; Lui, Charles; Grimmett, Garfield; Srinivasan, Venkatraman; Ariani, Kevin; Khan, Waqor; Blankenship, James; Cannon, Louis; Eisenberg, Steven; McLaurin, Brent; Mahoney, Paul; Greenberg, Jerry; Breall, Jeffrey; Chandna, Harish; Hockstad, Eric; Tolerico, Paul; Kao, John; Shroff, Adhir; Nseir, Georges; Greenbaum, Adam; Cohn, Joel; Gogia, Harinder; Nahhas, Ahed; Istfan, Pierre; Orlow, Steve; Spriggs, Douglas; Sklar, Joel; Paulus, Richard; Cochran, David; Smith, Robert; Ferrier, L. Norman; Scott, J. Christopher; Xenopoulos, Nicholaos; Mulumudi, Mahesh; Hoback, James; Ginete, Wilson; Ballard, William; Stella, Joseph; Voeltz, Michele; Staniloae, Cezar; Eaton, Gregory; Griffin, John; Kumar, Krishna; Ebrahimi, Ramin; O'Shaughnessy, Charles; Lundstrom, Lundstrom; Temizer, Dogan; Tam, Kenneth; Suarez, Jose; Raval, Amish; Kaufman, Jay; Brilakis, Emmanouil; Stillabower, Michael; Quealy, Kathleen; Nunez, Boris; Pow, Thomas; Samuels, Bruce; Argenal, Agustin; Srinivas, Vankeepuram; Rosenthal, Andrew; Tummala, Pradyumna; Myers, Paul; LaMarche, Nelson; Chan, Michael; Bach, Richard; Simon, Daniel; Kettelkamp, Richard; Helmy, Tarek; Schaer, Gary; Kosinski, Edward; Buchbinder, Maurice; Sharma, Mukesh; Goodwin, Mark; Horwitz, Phillip; Mann, J. Tift; Holmes, David; Angiolillo, Dominick; Rao, Sunil; Azrin, Michael; Gammon, Roger; Mavromatis, Kreton; Ahmed, Abdel; Kent, Kenneth; Zughaib, Marcel; Westcott, R. Jeffrey; Jain, Ash; Gruberg, Luis; LeGalley, Thomas

    2009-01-01

    BACKGROUND: Intravenous cangrelor, a rapid-acting, reversible adenosine diphosphate (ADP) receptor antagonist, might reduce ischemic events during percutaneous coronary intervention (PCI). METHODS: In this double-blind, placebo-controlled study, we randomly assigned 5362 patients who had not been

  13. Effect of intravenous dexmedetomidine infusion on some ...

    African Journals Online (AJOL)

    Background: This study was designed to evaluate the effect of intravenous dexmedetomidine infusion in patients undergoing major abdominal surgery on stress response markers as plasma interleukin-6, cortisol and blood glucose level. It also assessed its effect on recovery profile and postoperative pain. Methods: Thirty ...

  14. Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes.

    Science.gov (United States)

    Heintzmann, Rainer; Sarafis, Vassilios; Munroe, Paul; Nailon, John; Hanley, Quentin S; Jovin, Thomas M

    2003-01-01

    Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in signal-to-noise ratio. The latter can be increased further with the technique of weighted averaging in Fourier-space. A comparison of 2D and 3D experimental data analysed with subtractive imaging, the equivalent Fourier-space processing of the confocal data only, and Fourier-space weighted averaging is presented.

  15. On the usefulness of portal monitor unit subtraction in radiation therapy

    International Nuclear Information System (INIS)

    Kuperman, Vadim Y; Lubich, Leslie M

    2003-01-01

    In order to avoid additional dose to patients caused by portal imaging with megavoltage x-rays, portal monitor units (MUs) are frequently subtracted from the actual treatment MUs. This study examines the usefulness of portal MU subtraction in radiation therapy. For 11 prostate cancer patients treated with 23 MV photons, dose to prostate due to portal filming with 6 MV photons was determined. In all 11 patients subtraction of portal MU values from the actual treatment MUs resulted in a small underdosing of the prostate with an average treatment error of -0.5%. Portal filming without MU subtraction would cause small overdosing of the prostate with an average treatment error of 1.2%. The results of this study indicate that the benefits of portal MU subtraction are in doubt if (a) the energy of treatment x-rays is much higher than that of the portal x-rays and/or (b) when radiotherapy is performed with physical wedges. Based on the obtained results, we argue against unconditional use of the portal MU subtraction method to eliminate the dose from portal imaging

  16. [Construction of suppression subtracted cDNA library of deltamethrin-resistant Aedes albopictus].

    Science.gov (United States)

    Wu, Jia-hong; Zhao, Tong-yan; Dong, Yan-de

    2006-08-01

    To construct the suppression subtracted cDNA library of deltamethrin-resistant Aedes albopictus. Total RNA was extracted from the deltamethrin-resistant (R-lab) and -sensitive (S-lab) isolates, mRNA was obtained after purification. Double stranded cDNAs were synthesized after reverse transcription. Two subtractions were performed by suppression subtractive hybridization with S-lab as tester and R-lab as driver or S-lab as driver and R-lab as tester. Enriched different expressed cDNA was cloned into pMD18-T vector to construct subtractive libraries. The subtracted cDNA libraries contained 580 and 477 positive clones respectively. The PCR results of 150 clones picked randomly from each library showed that the positive ratio of constructed cDNA libraries was 93%, with a length of cDNA fragments ranged from 150bp to 750bp. The suppression subtracted cDNA library of deltamethrin-resistant Ae. albopictus is constructed.

  17. [Construction of the subtracted cDNA libraries related to artemisinin-resistance of Plasmodium berghei].

    Science.gov (United States)

    Bei, Zhu-chun; Wang, Jing-yan

    2004-06-01

    To construct the subtracted cDNA libraries related to artemisinin-resistance of Plasmodium berghei using suppression subtractive hybridization PCR (SSH PCR). Total RNA was extracted from the artemisinin-sensitive (NS) and artemisinin-resistant (AR) strains of Plasmodium berghei K173. The cDNA synthesis followed the protocol of super SMART cDNA synthesis kit. Taking the NS as driver, AR as tester and reverse, two subtractions were performed by SSH PCR. Enriched different expressed cDNA was cloned into pMD18-T vector to construct subtractive libraries. The subtracted cDNA libraries of NS-AR and AR-NS contained 395 and 506 positive clones respectively. The PCR results of 108 clones picked randomly from each library showed 100 and 104 positive inserts contained in the plasmids respectively, and distributing in 250-2000 bp. The successful construction of the subtracted cDNA libraries related to artemisinin-resistance of P. berghei enable us to identify the different expressed genes involved in the resistance mechanism.

  18. Thallium-201 and technetium-99m pertechnetate subtraction scintigraphy in patients with hyperparathyroidism

    International Nuclear Information System (INIS)

    Kuwashima, Shigeko; Koizumi, Mitsuru; Goto, Masafumi; Nomura, Toshiharu; Fujioka, Mutsuhisa; Watari, Tsutomu

    1992-01-01

    A reliable technique for detecting and localizing abnormal parathyroid tissue has been a persistent problem. We evaluated thallium-technetium (Tl/Tc) subtraction scintigraphy in 16 patients with clinical biochemical evidence of hyperparathyroidism prior to other diagnostic methods and surgery. Seven patients had surgery and were confirmed to have parathyroid adenoma or hyperplasia. The other methods included ultrasonography (US) in 6 patients, computed tomography (CT) in 10 patients, magnetic resonance imaging (MRI) in 8 patients, and bone scintigraphy in 7 patients. In patients who had several imaging modalities, the detection rate was significantly better for Tl/Tc subtraction scan than for US, CT or MRI. Bote scintigraphy, though not so sensitive as Tl/Tc subtraction studies, was an important tool for evaluating metabolic bone disorder including hyperparathyroidism and renal osteodystrophy. Thus, Tl/Tc subtraction scan is more useful for diagnosis when hyperparathyroidism is suspected if both Tl/Tc subtraction scan and bone scan are performed. The detectability depended on the mass size, and detection of abnormal glands was greater for adenoma than for hyperplasia. The results suggest that Tl/Tc subtraction scan is a simple, non-invasive and useful tool for locating parathyroid abnormality even when compared with MRI. (author)

  19. KIDNEY DISEASE VISUALIZED ON DIGITAL PROCESSOR

    Directory of Open Access Journals (Sweden)

    Rade R. Babić

    2013-09-01

    Full Text Available Radiological methods of examination in diagnosis of pathological conditions and diseases of urinary system are numerous and various, reliable and dominant. They became indispensable and without competition, among other diagnostic methods, using the digital techniques. The aim of this paper was to present the radiological image of pathological conditions and diseases of urinary system diagnosed by intravenous urography using digital techniques and to show the diagnostic possibilities and importance of digital techniques in diagnostic radiology. The paper analyzes pathological conditions and diseases of the kidney in a series of 3100 intravenous urographies (IVU performed at the Radiology Center, Clinical Center Niš, during the period 2009-2012. Radiographic examination was performed on X-ray device with a TV chain Schimadzu. IVU was performed according to the standard protocol. Contrast media: Ultravist 370®. X-ray images were digitally processed in Agfa CR-30 digital processor. The results are shown illustratively, by urographic images - anomalies, calculosis, hydronephrosis, tumors and other pathological conditions and diseases of the urinary system. This paper presents numerous and various pathological conditions and diseases of the urinary system. Among the valuable radiological examination methods IVU has maintained a leading position. The usage of digital techniques made IVU faster, easy and efficient method of examination, while the obtained urograms are of satisfactory quality and adequate contrast visualization of the urinary system.

  20. Digital mammography

    International Nuclear Information System (INIS)

    Bick, Ulrich; Diekmann, Felix

    2010-01-01

    This state-of-the-art reference book provides in-depth coverage of all aspects of digital mammography, including detector technology, image processing, computer-aided diagnosis, soft-copy reading, digital workflow, and PACS. Specific advantages and disadvantages of digital mammography in comparison to screen-film mammography are thoroughly discussed. By including authors from both North America and Europe, the book is able to outline variations in the use, acceptance, and quality assurance of digital mammography between the different countries and screening programs. Advanced imaging techniques and future developments such as contrast mammography and digital breast tomosynthesis are also covered in detail. All of the chapters are written by internationally recognized experts and contain numerous high-quality illustrations. This book will be of great interest both to clinicians who already use or are transitioning to digital mammography and to basic scientists working in the field. (orig.)

  1. Pedicle subtraction osteotomy in elderly patients with degenerative sagittal imbalance.

    Science.gov (United States)

    Cho, Kyu-Jung; Kim, Ki-Tack; Kim, Whoan-Jeang; Lee, Sang-Hoon; Jung, Jae-Hoon; Kim, Young-Tae; Park, Hae-Bong

    2013-11-15

    Retrospective, radiographical analysis. To evaluate pedicle subtraction osteotomy (PSO) as a means of correcting severe degenerative sagittal imbalance in elderly patients. PSO in patients with degenerative sagittal imbalance is likely to cause more complications than in patients with iatrogenic flatback deformity. This study analyzed 34 patients who underwent fusion to the sacrum, with a minimum 2-year follow-up. Age of the patients were in the range from 58 to 73 with the mean at 65.5 years. PSO was performed at one segment in all cases, consisting of L3 (n = 26), L4 (n = 4), L2 (n = 3), and L1 (n = 1). The average number of levels fused was 8.15. Ten patients had structural interbody fusion at the lumbosacral junction. Applying PSO at one segment, the mean correction of the lordotic angle at the osteotomy site was 33.3°, of which the loss of correction (LOC) was 4.0° at the last visit. The correction of lumbar lordosis was 33.7° and the LOC was 8.5°. The sagittal C7 plumb was 215.9 mm before surgery, corrected to 35.1 mm after surgery, and changed to 95.9 mm by the last visit. The correction of the sagittal C7 plumb was 119.9 mm and the LOC was 60.9 mm. There was substantial LOC in lumbar lordosis and sagittal C7 plumb. In 10 patients with addition of posterior lumbar interbody fusion, the LOC of lumbar lordosis was 7.4°, which was less than 9° in those without it. PSO for the correction of degenerative sagittal imbalance in elderly patients resulted in correction of sagittal alignment with a significant LOC of lumbar lordosis and sagittal C7 plumb. The LOC of lumbar lordosis occurred at both the osteotomy and non-osteotomy site. The addition of anterior column support is helpful to maintain correction and reduce complications. N/A.

  2. Digital Signage

    OpenAIRE

    Fischer, Karl Peter

    2011-01-01

    Digital Signage for in-store advertising at gas stations/retail stores in Germany: A field study Digital Signage networks provide a novel means of advertising with the advantage of easily changeable and highly customizable animated content. Despite the potential and increasing use of these media empirical research is scarce. In a field study at 8 gas stations (with integrated convenience stores) we studied the effect of digital signage advertising on sales for different products and servi...

  3. Digital Forensics

    OpenAIRE

    Garfinkel, Simson L.

    2013-01-01

    A reprint from American Scientist the magazine of Sigma Xi, The Scientific Research Society Since the 1980s, computers have had increasing roles in all aspects of human life—including an involvement in criminal acts. This development has led to the rise of digital forensics, the uncovering and examination of evidence located on all things electronic with digital storage, including computers, cell phones, and networks. Digital forensics researchers and practitione...

  4. Computerized detection of mass lesions in digital mammograms

    International Nuclear Information System (INIS)

    Yin, F.F.; Giger, M.L.; Doi, K.; Metz, C.E.; Vyborny, C.J.; Schmidt, R.A.

    1989-01-01

    Early detection of breast cancer from the periodic screening of asymptomatic women could reduce breast cancer mortality by at least 40%. The authors are developing a computerized scheme for the detection of mass lesions in digital mammograms as an aid to radiologists in such high volume screening programs. Based on left-right architectural symmetry and gray-level histogram analysis, bilateral subtraction of left and right breast images is performed. False-positive detections included in bilateral-difference images are reduced with various images feature-extraction techniques. The database involves clinical film mammograms digitized by a TV camera and analyzed on a Micro-VAX workstation. Among five different bilateral subtraction techniques investigated, a nonlinear approach provided superior lesion enhancement. Feature-extraction techniques reduced substantially the remaining false-positives. Preliminary results, for 32 pairs of clinical mammograms, yielded a true-positive rate of approximately 95% with a false-positive rate of about 2 per image

  5. Cost-effectiveness of oral phenytoin, intravenous phenytoin, and intravenous fosphenytoin in the emergency department.

    Science.gov (United States)

    Rudis, Maria I; Touchette, Daniel R; Swadron, Stuart P; Chiu, Amy P; Orlinsky, Michael

    2004-03-01

    Oral phenytoin, intravenous phenytoin, and intravenous fosphenytoin are all commonly used for loading phenytoin in the emergency department (ED). The cost-effectiveness of each was compared for patients presenting with seizures and subtherapeutic phenytoin concentrations. A simple decision tree was developed to determine the treatment costs associated with each of 3 loading techniques. We determined effectiveness by comparing adverse event rates and by calculating the time to safe ED discharge. Time to safe ED discharge was defined as the time at which therapeutic concentrations of phenytoin (>or=10 mg/L) were achieved with an absence of any adverse events that precluded discharge. The comparative cost-effectiveness of alternatives to oral phenytoin was determined by combining net costs and number of adverse events, expressed as cost per adverse events avoided. Cost-effectiveness was also determined by comparing the net costs of each loading technique required to achieve the time to safe ED discharge, expressed as cost per hour of ED time saved. The outcomes and costs were primarily derived from a prospective, randomized controlled trial, augmented by time-motion studies and alternate-cost sources. Costs included the cost of drugs, supplies, and personnel. Analyses were also performed in scenarios incorporating labor costs and savings from using a lower-urgency area of the ED. The mean number of adverse events per patient for oral phenytoin, intravenous phenytoin, and intravenous fosphenytoin was 1.06, 1.93, and 2.13, respectively. Mean time to safe ED discharge in the 3 groups was 6.4 hours, 1.7 hours, and 1.3 hours. Cost per patient was 2.83 dollars, 21.16 dollars, and 175.19 dollars, respectively, and did not differ substantially in the Labor and Triage (lower-urgency area of ED) scenarios. When the measure of effectiveness was adverse events, oral phenytoin dominated intravenous phenytoin and intravenous fosphenytoin, with a lower cost and number of adverse

  6. Intravenous/oral ciprofloxacin therapy versus intravenous ceftazidime therapy for selected bacterial infections.

    Science.gov (United States)

    Gaut, P L; Carron, W C; Ching, W T; Meyer, R D

    1989-11-30

    The efficacy and toxicity of sequential intravenous and oral ciprofloxacin therapy was compared with intravenously administered ceftazidime in a prospective, randomized, controlled, non-blinded trial. Thirty-two patients (16 patients receiving ciprofloxacin and 16 patients receiving ceftazidime) with 38 infections caused by susceptible Pseudomonas aeruginosa, enteric gram-negative rods, Salmonella group B, Serratia marcescens, Pseudomonas cepacia, and Xanthomonas maltophilia at various sites were evaluable for determination of efficacy. Length of therapy varied from seven to 25 days. Concomitant antimicrobials included intravenously administered beta-lactams for gram-positive organisms, intravenous/oral metronidazole and clindamycin for anaerobes, and intravenous/local amphotericin B for Candida albicans. Intravenous administration of 200 mg ciprofloxacin every 12 hours to 11 patients produced peak serum levels between 1.15 and 3.12 micrograms/ml; trough levels ranged between 0.08 and 0.86 micrograms/ml. Overall response rates were similar for patients receiving ciprofloxacin and ceftazidime. Emergence of resistance was similar in both groups--one Enterobacter cloacae and two P. aeruginosa became resistant after ciprofloxacin therapy and two P. aeruginosa became resistant after ceftazidime therapy. The frequency of superinfection with a variety of organisms was also similar in both groups. Adverse events related to ciprofloxacin included transient pruritus at the infusion site and generalized rash leading to drug discontinuation (one patient each), and with ceftazidime adverse effects included pain at the site of infusion and the development of allergic interstitial nephritis (one patient each). Overall, intravenous/oral ciprofloxin therapy appears to be as safe and effective as intravenous ceftazidime therapy in the treatment of a variety of infections due to susceptible aerobic gram-negative organisms.

  7. Evaluation of the effects of intravenous anaesthesia using a ...

    African Journals Online (AJOL)

    medetomidine for total intravenous anaesthesia were evaluated in six sahel goats. The goats were administered a combination of ketamine (5mg/kg) and medetomidine (0.01mg/kg) intravenously. Baseline measurements of heart rate, respiratory ...

  8. X-ray images in the digital mode

    International Nuclear Information System (INIS)

    Buchmann, F.; Balter, S.

    1981-01-01

    In addition to computed tomography which presents actually the most important processing and transfer procedure of digital X-ray images, application of real time addition and substraction of X-ray images in a digital mode has found considerable interest. An estimation of the information contents of both digital and analog images is made in close relation to applications. As example of an image processing system on digital base a recently developed system for intravenous arteriography is described: the Philips-DVI. (orig.) [de

  9. Use of Iodine-based contrast media in digital full-field mammography - initial experience

    International Nuclear Information System (INIS)

    Diekmann, F.; Diekmann, S.; Taupitz, M.; Bick, U.; Winzer, K.-J.; Huettner, C.; Muller, S.; Jeunehomme, F.; Hamm, B.

    2003-01-01

    Aim: To investigate the use of iodine-based contrast media in digital full-field mammography. Methods: After performing initial phantom studies, seven patients underwent digital mammography (Senographe 2000D, GE Medical Systems, Milwaukee, USA) using a specially filtered beam before as well as 60, 120, and 180 seconds after injection of 80 ml of iodine contrast medium (Ultravist 370, Schering AG, Germany). The precontrast mammograms were then subtracted from the postcontrast mammograms and the resulting images compared with a contrast-enhanced dynamic MRI study, performed on all women. Results: Contrast medium accumulation within the tumors was visualized with a good quality in all cases. The conditions under which successful contrast-enhanced digital mammography can be performed were determined in phantom studies. Conclusions: Contrast-enhanced digital mammography has a potential for improving the visualization of breast tumors in mammography using special beam filtering, adjusted X-ray parameters, proper timing, and suitable subtraction software. (orig.) [de

  10. Potential Cost Savings of Contrast-Enhanced Digital Mammography.

    Science.gov (United States)

    Patel, Bhavika K; Gray, Richard J; Pockaj, Barbara A

    2017-06-01

    The purpose of this article is to discuss whether the sensitivity and specificity of contrast-enhanced digital mammography (CEDM) render it a viable diagnostic alternative to breast MRI. That CEDM couples low-energy images (comparable to the diagnostic quality of standard mammography) and subtracted contrast-enhanced mammograms make it a cost-effective modality and a realistic substitute for the more costly breast MRI.

  11. Optimal timing for intravenous administration set replacement.

    Science.gov (United States)

    Gillies, D; O'Riordan, L; Wallen, M; Morrison, A; Rankin, K; Nagy, S

    2005-10-19

    Administration of intravenous therapy is a common occurrence within the hospital setting. Routine replacement of administration sets has been advocated to reduce intravenous infusion contamination. If decreasing the frequency of changing intravenous administration sets does not increase infection rates, a change in practice could result in considerable cost savings. The objective of this review was to identify the optimal interval for the routine replacement of intravenous administration sets when infusate or parenteral nutrition (lipid and non-lipid) solutions are administered to people in hospital via central or peripheral venous catheters. We searched The Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, CINAHL, EMBASE: all from inception to February 2004; reference lists of identified trials, and bibliographies of published reviews. We also contacted researchers in the field. We did not have a language restriction. We included all randomized or quasi-randomized controlled trials addressing the frequency of replacing intravenous administration sets when parenteral nutrition (lipid and non-lipid containing solutions) or infusions (excluding blood) were administered to people in hospital via a central or peripheral catheter. Two authors assessed all potentially relevant studies. We resolved disagreements between the two authors by discussion with a third author. We collected data for the outcomes; infusate contamination; infusate-related bloodstream infection; catheter contamination; catheter-related bloodstream infection; all-cause bloodstream infection and all-cause mortality. We identified 23 references for review. We excluded eight of these studies; five because they did not fit the inclusion criteria and three because of inadequate data. We extracted data from the remaining 15 references (13 studies) with 4783 participants. We conclude that there is no evidence that changing intravenous administration sets more often than every 96 hours

  12. Running the number line: Rapid shifts of attention in single-digit arithmetic.

    Science.gov (United States)

    Mathieu, Romain; Gourjon, Audrey; Couderc, Auriane; Thevenot, Catherine; Prado, Jérôme

    2016-01-01

    It has been recently proposed that adults might solve single-digit addition and subtraction problems by rapidly moving through an ordered representation of numbers. In the present study, we tested whether these movements manifest themselves by on-line shifts of attention during arithmetic problem-solving. In two experiments, adult participants were presented with single-digit addition, subtraction and multiplication problems. Operands and operator were presented sequentially on the screen. Although both the first operand and the operator were presented at the center of the screen, the second operand was presented either to the left or to the right side of space. We found that addition problems were solved faster when the second operand appeared to the right than to the left side (Experiments 1 & 2). In contrast, subtraction problems were solved faster when the second operand appeared to the left than to the right side (Experiment 1). No operation-dependent spatial bias was observed in the same time window when the second operand was zero (Experiment 1), and no bias was observed when the operation was a multiplication (Experiment 2). Therefore, our results demonstrate that solving single-digit addition and subtraction, but not multiplication, is associated with horizontal shifts of attention. Our findings support the idea that mental movements to the left or right of a sequential representation of numbers are elicited during single-digit arithmetic. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Digital Audiobooks

    DEFF Research Database (Denmark)

    Have, Iben; Pedersen, Birgitte Stougaard

    Audiobooks are rapidly gaining popularity with widely accessible digital downloading and streaming services. The paper is framing how the digital audiobook expands and changes the target groups for book publications and how it as an everyday activity is creating new reading experiences, places...

  14. Digital mammography

    International Nuclear Information System (INIS)

    Cho, Nariya; Cha, Joo Hee; Moon, Woo Kyung

    2005-01-01

    Mammography is the best imaging modality for the detection of early breast cancer in asymptomatic women. However, 10-30% of cases are missed with current film-screen mammography. Digital mammography allows for the separate optimization of image acquisition and display. In addition to the obvious data storage, retrieval, and transmission advantages that digital mammography allows, additional advances such as computer-aided diagnosis, tomosynthesis and dual energy mammography are in development. This review will discuss the technology of digital mammography including detectors and displays, the results of clinical trials comparing film-screen and digital mammography, and the use of computer-aided detection. Digital mammography is a promising new technology for breast cancer detection in the Korean women

  15. Digital Humanities

    DEFF Research Database (Denmark)

    Brügger, Niels

    2016-01-01

    Digital humanities is an umbrella term for theories, methodologies, and practices related to humanities scholarship that use the digital computer as an integrated and essential part of its research and teaching activities. The computer can be used for establishing, finding, collecting, and preser......Digital humanities is an umbrella term for theories, methodologies, and practices related to humanities scholarship that use the digital computer as an integrated and essential part of its research and teaching activities. The computer can be used for establishing, finding, collecting......, and preserving material to study, as an object of study in its own right, as an analytical tool, or for collaborating, and for disseminating results. The term "digital humanities" was coined around 2001, and gained currency within academia in the following years. However, computers had been used within...

  16. Digital displacements

    DEFF Research Database (Denmark)

    Pors, Anja Svejgaard

    2014-01-01

    digital interface. However, the transformation of citizen services from traditional face-to-face interaction to digital self-service gives rise to new practices; some citizens need support to be able to manage self-service through digital tools. A mixture of support and teaching, named co...... digital reforms in Denmark and shows how citizen service is transformed from service to support. The frontline employee’s classical tasks such as casework are being displaced into educational and support-oriented tasks with less professional content. Thus an unintended effect of digitisation is blurred......In recent years digital reforms are being introduced in the municipal landscape of Denmark. The reforms address the interaction between citizen and local authority. The aim is, that by 2015 at least 80 per cent of all correspondence between citizens and public authority will be transmitted through...

  17. Sports Digitalization

    DEFF Research Database (Denmark)

    Xiao, Xiao; Hedman, Jonas; Tan, Felix Ter Chian

    2017-01-01

    evolution, as digital technologies are increasingly entrenched in a wide range of sporting activities and for applications beyond mere performance enhancement. Despite such trends, research on sports digitalization in the IS discipline is surprisingly still nascent. This paper aims at establishing......Ever since its first manifesto in Greece around 3000 years ago, sports as a field has accumulated a long history with strong traditions while at the same time, gone through tremendous changes toward professionalization and commercialization. The current waves of digitalization have intensified its...... a discourse on sports digitalization within the discipline. Toward this, we first provide an understanding of the institutional characteristics of the sports industry, establishing its theoretical importance and relevance in our discipline; second, we reveal the latest trends of digitalization in the sports...

  18. Real-Time Digital Video Recording System

    Science.gov (United States)

    Van Lysel, M. S.; Zarnstorff, W. C.; Lancaster, J. C.; Mistretta, C. A.; Dobbins, J. T.

    1981-11-01

    Image storage is a necessary consideration in a medical imaging system. Data generated by recently developed digital radiographic techniques may be stored on magnetic tape or disc in either analog or digital form. Video discs have desirable freeze frame and image sequencing properties allowing for flexible image manipulation and display. Whereas digital pre-processing has enabled excellent results to be obtained using analog storage, digital storage is ideal as far as bandwidth and noise properties are concerned. However, serial data rates of digital disc drives are limited to about 10 megabits per second, too slow for recording video information in real-time. Using a standard multi-platter magnetic disc drive we have constructed parallel read/write channels servicing sets of 9 or 10 surfaces simultaneously in order to achieve a data rate of 100 megabits per second. This permits storage of 815 512x512x9 bit images at 30 frames per second. Hardware configurations and applications of the real-time digital disc to subtraction angiography will be discussed.

  19. Intravenous immunoglobulin therapy for refractory recurrent pericarditis.

    Science.gov (United States)

    del Fresno, M Rosa; Peralta, Julio E; Granados, Miguel Ángel; Enríquez, Eugenia; Domínguez-Pinilla, Nerea; de Inocencio, Jaime

    2014-11-01

    Recurrent pericarditis is a troublesome complication of idiopathic acute pericarditis and occurs more frequently in pediatric patients after cardiac surgery (postpericardiotomy syndrome). Conventional treatment with nonsteroidal antiinflammatory drugs, corticosteroids, and colchicine is not always effective or may cause serious adverse effects. There is no consensus, however, on how to proceed in those patients whose disease is refractory to conventional therapy. In such cases, human intravenous immunoglobulin, immunosuppressive drugs, and biological agents have been used. In this report we describe 2 patients with refractory recurrent pericarditis after cardiac surgery who were successfully treated with 3 and 5 monthly high-dose (2 g/kg) intravenous immunoglobulin until resolution of the effusion. Our experience supports the effectiveness and safety of this therapy. Copyright © 2014 by the American Academy of Pediatrics.

  20. Retroperitoneal fibrosis with normal intravenous urogram.

    OpenAIRE

    Creagh, F. M.; Stone, T.; Stephenson, T. P.; Lazarus, J. H.

    1985-01-01

    A 58 year old male presented with a two week history of low back pain and malaise. The intravenous urogram (IVU) at presentation was normal but within three months he had developed renal failure with bilateral ureteric obstruction on repeat IVU. Primary retroperitoneal fibrosis was confirmed at operation. This case demonstrates that retroperitoneal fibrosis may progress rapidly to renal failure within a few months of the first symptoms. In addition, the IVU may be normal in the early stages o...

  1. Total intravenous anesthesia for major burn surgery

    OpenAIRE

    Cancio, Leopoldo C; Cuenca, Phillip B; Walker, Stephen C; Shepherd, John M

    2013-01-01

    Total intravenous anesthesia (TIVA) is frequently used for major operations requiring general anesthesia in critically ill burn patients. We reviewed our experience with this approach. Methods: During a 22-month period, 547 major burn surgeries were performed in this center’s operating room and were staffed by full-time burn anesthesiologists. The records of all 123 TIVA cases were reviewed; 112 records were complete and were included. For comparison, 75 cases were selected at random from a t...

  2. Contrast agent choice for intravenous coronary angiography

    International Nuclear Information System (INIS)

    Zeman, H.D.; Siddons, D.P.

    1989-01-01

    The screening of the general population for coronary artery disease would be practical if a method existed for visualizing the extent of occlusion after an intravenous injection of contrast agent. Measurements performed with monochromatic synchrotron radiation x-rays and an iodine containing contrast agent at the Stanford Synchrotron Radiation Laboratory have shown that such an intravenous angiography procedure would be possible with an adequately intense monochromatic x-ray source. Because of the size and cost of synchrotron radiation facilities it would be desirable to make the most efficient use of the intensity available, while reducing as much as possible the radiation dose experienced by the patient. By choosing contrast agents containing elements with a higher atomic number than iodine, it is possible to both improve the image quality and reduce the patient radiation dose, while using the same synchrotron source. By using Si monochromator crystals with a small mosaic spread, it is possible to increase the x-ray flux available for imaging by over an order of magnitude, without any changes in the storage ring or wiggler magnet. The most critical imaging task for intravenous coronary angiography utilizing synchrotron radiation x-rays is visualizing a coronary artery through the left ventricle or aorta which also contains a contrast agent. Calculations have been made of the signal to noise ratio expected for this imaging task for various contrast agents with atomic numbers between that of iodine and bismuth

  3. Intravenous Lipids for Preterm Infants: A Review

    Directory of Open Access Journals (Sweden)

    Ghassan S. A. Salama

    2015-01-01

    Full Text Available Extremely low birth weight infants (ELBW are born at a time when the fetus is undergoing rapid intrauterine brain and body growth. Continuation of this growth in the first several weeks postnatally during the time these infants are on ventilator support and receiving critical care is often a challenge. These infants are usually highly stressed and at risk for catabolism. Parenteral nutrition is needed in these infants because most cannot meet the majority of their nutritional needs using the enteral route. Despite adoption of a more aggressive approach with amino acid infusions, there still appears to be a reluctance to use early intravenous lipids. This is based on several dogmas that suggest that lipid infusions may be associated with the development or exacerbation of lung disease, displace bilirubin from albumin, exacerbate sepsis, and cause CNS injury and thrombocytopena. Several recent reviews have focused on intravenous nutrition for premature neonate, but very little exists that provides a comprehensive review of intravenous lipid for very low birth and other critically ill neonates. Here, we would like to provide a brief basic overview, of lipid biochemistry and metabolism of lipids, especially as they pertain to the preterm infant, discuss the origin of some of the current clinical practices, and provide a review of the literature, that can be used as a basis for revising clinical care, and provide some clarity in this controversial area, where clinical care is often based more on tradition and dogma than science.

  4. Subtraction-multiphase-CT unbeneficial for early detection of colorectal liver metastases

    International Nuclear Information System (INIS)

    Meijerink, Martijn R.; Waesberghe, Jan Hein T.M. van; Golding, Richard P.; Weide, Lineke van der; Tol, Petrousjka van den; Meijer, Sybren; Kuijk, Cornelis van

    2010-01-01

    Purpose: To assess the value of multiphase-subtraction-CT for early detection of colorectal-liver-metastases (CRLM). Methods and materials: In 50 patients suspected of CRLM a routine pre-operative 4-phase-CT-scan of the upper abdomen was obtained. All 12 possible image subtractions between two different phases were constructed applying 3D-image-registration to decrease distortion artefacts induced by differences in inspiration volume. Two experienced radiologists initially reviewed the conventional 4-phase-CT for malignant and/or benign appearing lesions and at least 1-month hereafter the same 4-phase-CT now including the subtracted images. The results were compared to histology reports or to a combination of surgical exploration and intraoperative ultrasound together with results from pre-operative PET and follow-up examinations. Results: Although an additional number of 31 malignant appearing lesions were detected on the subtraction images, none proved to represent a true CRLM. Interobserver agreement (κ) decreased from 0.627 (good) to 0.418 (fair). Conclusion: Adding linearly co-registered subtraction-CT images to a conventional 4-phase-CT protocol does not improve detection of CRLM.

  5. A computer-assisted method for 3D subtraction angiography based on spiral CT

    International Nuclear Information System (INIS)

    Englmeier, K.H.; Fink, U.; Haubner, M.; Becker, C.; Seemann, M.; Capeller, W.; Reiser, M.

    1996-01-01

    The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is applied to a pair of image volumes. After detection of the disparities, which manifest as bright spots, the real shift of the two subsignals can be calculated. Translation of the corresponding image volume pairs to their correct positions improves the subtraction process. In all cases the size of the aneurysm and the abdominal organs could be better segmented and visualized. Application of the cepstrum filter and subtraction of the image volumes before, and after contrast medium injection completely removes the bony structures in the image data and results in superior visualization results. (orig./MG) [de

  6. The Automatic Recognition of the Abnormal Sky-subtraction Spectra Based on Hadoop

    Science.gov (United States)

    An, An; Pan, Jingchang

    2017-10-01

    The skylines, superimposing on the target spectrum as a main noise, If the spectrum still contains a large number of high strength skylight residuals after sky-subtraction processing, it will not be conducive to the follow-up analysis of the target spectrum. At the same time, the LAMOST can observe a quantity of spectroscopic data in every night. We need an efficient platform to proceed the recognition of the larger numbers of abnormal sky-subtraction spectra quickly. Hadoop, as a distributed parallel data computing platform, can deal with large amounts of data effectively. In this paper, we conduct the continuum normalization firstly and then a simple and effective method will be presented to automatic recognize the abnormal sky-subtraction spectra based on Hadoop platform. Obtain through the experiment, the Hadoop platform can implement the recognition with more speed and efficiency, and the simple method can recognize the abnormal sky-subtraction spectra and find the abnormal skyline positions of different residual strength effectively, can be applied to the automatic detection of abnormal sky-subtraction of large number of spectra.

  7. Removal of arterial wall calcifications in CT angiography by local subtraction

    International Nuclear Information System (INIS)

    Straten, Marcel van; Venema, Henk W.; Streekstra, Geert J.; Reekers, Jim A.; Heeten, Gerard J. den; Grimbergen, Cornelis A.

    2003-01-01

    CT Angiography (CTA) is an established technique for the minimally invasive imaging of arteries. The technique of maximum intensity projection (MIP) is often used to get a comprehensive overview of the vascular anatomy. On a MIP, however, arterial wall calcifications may hinder the visualization of the arterial lumen. These calcifications are in direct contact with the contrast-enhanced blood, which makes removal difficult. We present a local subtraction method for the automatic removal of these calcifications. In our approach a second CT scan has to be made, prior to contrast injection. The calcifications in both scans are registered prior to subtraction to compensate for displacements in between the two scans. Local subtraction results are compared with results obtained by thresholding. The method was tested in a phantom and with data from four patients. The phantom represented an artery with different types of stenosis. Data were used from patients for which CTA of the renal arteries was performed. For two patients the electrocardiogram (ECG) was recorded during the CTA examination, making retrospective cardiac gated reconstructions possible. Both the phantom and the patient study showed that the local subtraction method is capable of removing calcifications and visualizing the residual lumen. In the patient study it appeared that some artifacts remained for higher pitch values. We conclude that the local subtraction method is less subjective and more accurate than thresholding. Best results are obtained by use of a small pitch, at the expense of the volume covered during a single breath hold

  8. L5 pedicle subtraction osteotomy for high-grade isthmic spondylolisthesis.

    Science.gov (United States)

    Radcliff, Kristen E; Jakoi, Andre M

    2015-04-01

    To the authors' knowledge, this is the first article to present a pedicle subtraction osteotomy in the lumbar spine to correct and stabilize a high-grade isthmic spondylolisthesis, which poses many challenges with regard to treatment options and outcomes. The optimal surgical treatment for high-grade spondylolisthesis is controversial, but the goals of treatment are to stabilize the affected spinal levels and to decompress the neural elements. A pedicle subtraction osteotomy is a reconstructive procedure that addresses fixed sagittal imbalance by increasing lumbar lordosis through posterior spinal column shortening. The authors report a 46-year-old patient with chronic, progressively worsening back and leg radiculopathy accompanied by sagittal plane malalignment and for which a pedicle subtraction osteotomy was performed. The procedure yielded stabilization of the patient's lumbar spondylolisthesis and sagittal plane alignment was restoration. At 3 months postoperatively, the patient's pain had fully resolved and her motor and neurologic examination exhibited no deficits. At 24 months postoperatively, she was still symptom-free and ambulating without assistance. This report is the first documented successful pedicle subtraction osteotomy in the treatment of high-grade spondylolisthesis. This report indicates that certain patient populations may be amenable to pedicle subtraction osteotomy as a treatment option for pathology involving high-grade isthmic spondylolisthesis. Copyright 2015, SLACK Incorporated.

  9. Speech enhancement using parametric spectral subtraction combined with generalized sidelobe canceller

    Science.gov (United States)

    Cho, Jaeyoun; Krishnamurthy, Ashok

    2003-10-01

    Speech enhancement is an important problem with applications in hearing aid design, speech recognition, speech coding, etc. Parametric spectral subtraction is a common method for speech enhancement when only a single channel of data is available. On the other hand, beamforming methods can be used when multiple channels of spatially separated data are available, such as from a microphone array. In previous work, we have shown that spectral subtraction combined with spatial averaging from multiple microphones leads to improvements in speech SNR and reduction of musical noise compared with either method used alone. In this talk, we extend the previous work to combine parametric spectral subtraction with adaptive beamforming, specifically the generalized sidelobe canceller. The proposed parametric spectral subtraction method determines the parameters adaptively so as to minimize speech distortion. In addition, it is shown that the major drawback of spectral subtraction, so-called musical noise, can be diminished by adaptive beamforming process. We show that the method leads to a reduction of musical noise and results in the enhanced speech having better quality and intelligibility.

  10. Digital radiography

    International Nuclear Information System (INIS)

    Coulomb, M.; Dal Soglio, S.; Pittet-Barbier, L.; Ranchoup, Y.; Thony, F.; Ferretti, G.; Robert, F.

    1992-01-01

    Digital projection radiography may replace conventional radiography some day, provided it can meet several requirements: equal or better diagnostic effectiveness of the screen-film systems; reasonable image cost; real improvement in the productivity of the Departments of Imaging. All digital radiographic systems include an X-ray source, an image acquisition and formatting sub-system, a display and manipulation sub-system, and archiving subsystem and a laser editing system, preferably shared by other sources of digital images. Three digitization processes are available: digitization of the radiographic film, digital fluorography and phospholuminescent detectors with memory. The advantages of digital fluoroscopy are appealing: real-time image acquisition, suppression of cassettes; but its disadvantages are far from negligible: it cannot be applied to bedside radiography, the field of examination is limited, and the wide-field spatial resolution is poor. Phospholuminescent detectors with memory have great advantages: they can be used for bedside radiographs and on all the common radiographic systems; spatial resolution is satisfactory; its current disadvantages are considerable. These two systems, have common properties making up the entire philosophy of digital radiology and specific features that must guide our choice according to the application. Digital fluorography is best applied in pediatric radiology. However, evaluation works have showed that it was applicable with sufficient quality to many indications of general radiology in which a fluoroscopic control and fast acquisition of the images are essential; the time gained on the examination may be considerable, as well as the savings on film. Detectors with memory are required for bedside radiographs, in osteoarticular and thoracic radiology, in all cases of traumatic emergency and in the resuscitation and intensive care departments

  11. Better imaging: the advantages of digital radiography.

    Science.gov (United States)

    van der Stelt, Paul F

    2008-06-01

    Digital radiography has been available in dentistry for more than 25 years, but it has not replaced conventional film-based radiography completely. This could be because of the costs involved in replacing conventional radiographic equipment with a digital imaging system, or because implementing new technology in the dental practice requires a bit of courage. When the practitioner is fully aware of the new possibilities offered by digital radiography, he or she can make a more informed decision about adopting it. This article offers information about digital radiography, not just as a replacement of conventional radiography, but also as a concept offering benefits beyond those of conventional radiography. Digital radiographs are composed of a set of numbers arranged as a grid of rows and columns. The dentist can perform mathematical operations on these numbers to create a new image in which certain characteristics are enhanced, thus making interpretation of the image easier. The dentist also can correct, to some extent, overexposed or underexposed images and can optimize contrast and brightness for specific diagnostic procedures, such as caries detection and bone level assessment. More advanced procedures are available as well, such as digital subtraction radiography and computer-aided recognition of image features. The author presents a selection of the advantages of digital radiography that are not achievable with conventional film-based radiography. Implementing digital radiography in the dental office requires additional training. However, once members of the dental team have gone through this initial phase, they have the benefits of several new diagnostic possibilities. With a digital system, information from radiographic images is collected more easily and in a more objective way, which will improve the performance of the diagnostic process.

  12. Digital radiography

    International Nuclear Information System (INIS)

    Zani, M.L.

    2002-01-01

    X-ray radiography is a very common technique used to check the homogeneity of a material or the inside of a mechanical part. Generally the radiation that goes through the material to check, produced an image on a sensitized film. This method requires time because the film needs to be developed, digital radiography has no longer this inconvenient. In digital radiography the film is replaced by digital data and can be processed as any computer file. This new technique is promising but its main inconvenient is that today its resolution is not so good as that of film radiography. (A.C.)

  13. Digital electronics

    CERN Document Server

    Morris, John

    2013-01-01

    An essential companion to John C Morris's 'Analogue Electronics', this clear and accessible text is designed for electronics students, teachers and enthusiasts who already have a basic understanding of electronics, and who wish to develop their knowledge of digital techniques and applications. Employing a discovery-based approach, the author covers fundamental theory before going on to develop an appreciation of logic networks, integrated circuit applications and analogue-digital conversion. A section on digital fault finding and useful ic data sheets completes th

  14. Digital Leadership

    DEFF Research Database (Denmark)

    Zupancic, Tadeja; Verbeke, Johan; Achten, Henri

    2016-01-01

    Leadership is an important quality in organisations. Leadership is needed to introduce change and innovation. In our opinion, in architectural and design practices, the role of leadership has not yet been sufficiently studied, especially when it comes to the role of digital tools and media....... With this paper we intend to initiate a discussion in the eCAADe community to reflect and develop ideas in order to develop digital leadership skills amongst the membership. This paper introduces some important aspects, which may be valuable to look into when developing digital leadership skills....

  15. Digital radiography

    International Nuclear Information System (INIS)

    Kusano, Shoichi

    1993-01-01

    Firstly, from an historic point of view, fundamental concepts on digital imaging were reviewed to provide a foundation for discussion of digital radiography. Secondly, this review summarized the results of ongoing research in computed radiography that replaces the conventional film-screen system with a photo-stimulable phosphor plate; and thirdly, image quality, radiation protection, and image processing techniques were discussed with emphasis on picture archiving and communication system environment as our final goal. Finally, future expansion of digital radiography was described based on the present utilization of computed tomography at the National Defense Medical College Hospital. (author) 60 refs

  16. Expressed sequence tags: normalization and subtraction of cDNA libraries expressed sequence tags\\ normalization and subtraction of cDNA libraries.

    Science.gov (United States)

    Soares, Marcelo Bento; de Fatima Bonaldo, Maria; Hackett, Jeremiah D; Bhattacharya, Debashish

    2009-01-01

    Expressed Sequence Tags (ESTs) provide a rapid and efficient approach for gene discovery and analysis of gene expression in eukaryotes. ESTs have also become particularly important with recent expanded efforts in complete genome sequencing of understudied, nonmodel eukaryotes such as protists and algae. For these projects, ESTs provide an invaluable source of data for gene identification and prediction of exon-intron boundaries. The generation of EST data, although straightforward in concept, requires nonetheless great care to ensure the highest efficiency and return for the investment in time and funds. To this end, key steps in the process include generation of a normalized cDNA library to facilitate a high gene discovery rate followed by serial subtraction of normalized libraries to maintain the discovery rate. Here we describe in detail, protocols for normalization and subtraction of cDNA libraries followed by an example using the toxic dinoflagellate Alexandrium tamarense.

  17. Continuous-variable measurement-device-independent quantum key distribution with photon subtraction

    Science.gov (United States)

    Ma, Hong-Xin; Huang, Peng; Bai, Dong-Yun; Wang, Shi-Yu; Bao, Wan-Su; Zeng, Gui-Hua

    2018-04-01

    It has been found that non-Gaussian operations can be applied to increase and distill entanglement between Gaussian entangled states. We show the successful use of the non-Gaussian operation, in particular, photon subtraction operation, on the continuous-variable measurement-device-independent quantum key distribution (CV-MDI-QKD) protocol. The proposed method can be implemented based on existing technologies. Security analysis shows that the photon subtraction operation can remarkably increase the maximal transmission distance of the CV-MDI-QKD protocol, which precisely make up for the shortcoming of the original CV-MDI-QKD protocol, and one-photon subtraction operation has the best performance. Moreover, the proposed protocol provides a feasible method for the experimental implementation of the CV-MDI-QKD protocol.

  18. Enrichment of an in vivo phage display repertoire by subtraction for easy identification of pathology biomarkers

    Directory of Open Access Journals (Sweden)

    karina Vargas Sanchez

    2015-03-01

    Conclusion. This physical subtraction discarded from a complex repertoire the non-specific selected ligands. STRATEGY 1 Three rounds of in vivo phage peptide selection in EAE female Lewis rats ("EAE repertoire" vs controls ("HEALTHY repertoire". 2 DNA subtraction of the most common sequences between «HEALTHY» and «EAE» phage repertoires to obtain a third EAE specific «SUBTRACTION » phage repertoire. 3 Massive sequencing of the three repertoires and bioinformatic analysis to identify the peptides sequences with high EAE specificity. 4 Biological tests of potential EAE specific phage clones with CNS tissues from EAE and Healthy control rats. 5 Biological tests of the EAE specific peptide and phage clones on the BBB in vitro model (hCMEC/D3 cells under inflammatory conditions (IL-1β stimulation. 6 Target separation and identification by cross-link between the selected phage clones and hMEC/D3 endothelial cells targets under IL-1β stimulation vs controls.

  19. Spectral Subtraction Approach for Interference Reduction of MIMO Channel Wireless Systems

    Directory of Open Access Journals (Sweden)

    Tomohiro Ono

    2005-08-01

    Full Text Available In this paper, a generalized spectral subtraction approach for reducing additive impulsive noise, narrowband signals, white Gaussian noise and DS-CDMA interferences in MIMO channel DS-CDMA wireless communication systems is investigated. The interference noise reduction or suppression is essential problem in wireless mobile communication systems to improve the quality of communication. The spectrum subtraction scheme is applied to the interference noise reduction problems for noisy MIMO channel systems. The interferences in space and time domain signals can effectively be suppressed by selecting threshold values, and the computational load with the FFT is not large. Further, the fading effects of channel are compensated by spectral modification with the spectral subtraction process. In the simulations, the effectiveness of the proposed methods for the MIMO channel DS-CDMA is shown to compare with the conventional MIMO channel DS-CDMA.

  20. Dynamic contrast-enhanced subtraction MR angiography in intracranial vascular abnormalities

    International Nuclear Information System (INIS)

    Takano, K.; Ono, H.; Utsunomiya, H.; Okazaki, M.; Tanaka, A.

    1999-01-01

    We present our clinical experience with dynamic contrast-enhanced MR angiography (MRA) with subtraction for assessing intracranial vascular abnormalities. Ten patients with various cerebrovascular disorders underwent dynamic contrast-enhanced MRA on a 1.0-T system. Thirty sections (2 mm) were acquired in 29-30 s. Maximum intensity projection images and subtracted source images were compared with those obtained by conventional angiography. In all cases, the presence or absence of abnormalities in the targeted vessels, as well as the morphology of the sagittal sinuses, was clearly visualized as in conventional angiography, without any obstructions such as hyperintense hematomas or thrombi, or intraluminal turbulence. Although the temporal and spatial resolutions with current hardware are insufficient, these preliminary results suggest that dynamic contrast-enhanced MRA with subtraction may be useful for assessing vascular lesions with hemorrhage or thrombus, and the dural sinuses. (orig.)

  1. [Screening of high taxol producing fungi by mutagenesis and construction of subtracted cDNA library by suppression subtracted hybridization for differentially expressed genes].

    Science.gov (United States)

    Zhao, Kai; Sun, Lixin; Wang, Xuan; Li, Xiuliang; Wang, Xin; Zhou, Dongpo

    2011-07-01

    To screen mutants with high yield of taxol, and construct cDNA subtractive library of obtained mutant and primary strain HD(1-3). The spores of taxol-producing fungus HD(1-3) were treated by diethyl sulphate (DES), ultraviolet radiation and diethyl sulphate (UV + DES). cDNA subtractive library of taxol producing fungi from the mRNA of obtained mutant with high yield of taxol tester and HD(1-3) driver was constructed by using suppression subtracted hybridization (SSH). The optimal conditions for mutagenesis of strain HD(1-3) were as follows: the spore suspension was treated with 8% DES for 15 min, followed by UV irradiation (30 w, 30 cm distance) for 45 sec under magnetic stirring, a mutant UD(14-1) which was able to produce taxol with high yield and could be stably passed on genetics was found. Its ability to produce taxol was improved from 232.73 +/- 4.61 microg/L (strain HD(1-3)) to 312.81 +/- 7.51 microg/L (strain UD(14-1)). The tilter of the constructed cDNA library was 1.2 x 10(7) cfu/mL, the recombinant rate reached to 75.3% and the length of the inserted fragments was mostly 300 bp-1.0 kb. A mutant UD(14-11) with high yield was obtained, and cDNA subtractive library of the mutant UD(14-11) and strain HD(1-3) was constructed. The study laid solid foundation for isolation of taxol biosynthesis related genes and construction of engineering strains with high yield of taxol by genetic techniques.

  2. Digital Snaps

    DEFF Research Database (Denmark)

    Sandbye, Mette; Larsen, Jonas

    Purikura Photography / Mette Sandbye -- ch. 7. 'Buying an Instrument Does Not Necessarily Make You a Musician': Studio Photography and the Digital Revolution / Sigrid Lien -- pt. III. NEW PUBLIC FORMS -- ch. 8 Paparazzi Photography, Seriality and the Digital Photo Archive / Anne Jerslev and Mette Mortensen......The New Face of Snapshot Photography / Jonas Larsen and Mette Sandbye -- pt. I. IMAGES ON WEB 2.0 AND THE CAMERA PHONE -- ch. 1. Overlooking, Rarely Looking and Not Looking / Martin Lister -- ch. 2. The (Im)mobile Life of Digital Photographs: The Case of Tourist Photography / Jonas Larsen -- ch. 3....... Distance as the New Punctum / Mikko Villi -- pt. II. FAMILY ALBUMS IN TRANSITION -- ch. 4. How Digital Technologies Do Family Snaps, Only Better / Gillian Rose -- ch. 5. Friendship Photography: Memory, Mobility and Social Networking / Joanne Garde-Hansen -- ch. 6. Play, Process and Materiality in Japanese...

  3. Digital Discretion

    DEFF Research Database (Denmark)

    Busch, Peter Andre; Zinner Henriksen, Helle

    2018-01-01

    discretion is suggested to reduce this footprint by influencing or replacing their discretionary practices using ICT. What is less researched is whether digital discretion can cause changes in public policy outcomes, and under what conditions such changes can occur. Using the concept of public service values......This study reviews 44 peer-reviewed articles on digital discretion published in the period from 1998 to January 2017. Street-level bureaucrats have traditionally had a wide ability to exercise discretion stirring debate since they can add their personal footprint on public policies. Digital......, we suggest that digital discretion can strengthen ethical and democratic values but weaken professional and relational values. Furthermore, we conclude that contextual factors such as considerations made by policy makers on the macro-level and the degree of professionalization of street...

  4. Digital fabrication

    CERN Document Server

    2012-01-01

    The Winter 2012 (vol. 14 no. 3) issue of the Nexus Network Journal features seven original papers dedicated to the theme “Digital Fabrication”. Digital fabrication is changing architecture in fundamental ways in every phase, from concept to artifact. Projects growing out of research in digital fabrication are dependent on software that is entirely surface-oriented in its underlying mathematics. Decisions made during design, prototyping, fabrication and assembly rely on codes, scripts, parameters, operating systems and software, creating the need for teams with multidisciplinary expertise and different skills, from IT to architecture, design, material engineering, and mathematics, among others The papers grew out of a Lisbon symposium hosted by the ISCTE-Instituto Universitario de Lisboa entitled “Digital Fabrication – A State of the Art”. The issue is completed with four other research papers which address different mathematical instruments applied to architecture, including geometric tracing system...

  5. Becoming digital

    DEFF Research Database (Denmark)

    Pors, Anja Svejgaard

    2015-01-01

    . Originality/value: The study contributes to ethnographic research in public administration by combining two separate subfields, e-government and street-level bureaucracy, to discern recent transformations in public service delivery. In the digital era, tasks, control and equality are distributed in ways......The purpose of this paper is to examine the impact of e-government reforms on street-level bureaucrats’ professionalism and relation to citizens, thus demonstrating how the bureaucratic encounter unfolds in the digital era. Design/methodology/approach: The paper is based on an ethnographic study....... An ethnographic account of how digital reforms are implemented in practice shows how street-level bureaucrat’s classic tasks such as specialized casework are being reconfigured into educational tasks that promote the idea of “becoming digital”. In the paper, the author argues that the work of “becoming digital...

  6. Digital Bangladesh

    OpenAIRE

    Masudul Alam Choudhury

    2013-01-01

    The present fever to launch an extensive digitalization program is sweeping the Bangladesh political, business, and elitist minds. In the face of an overarching outlook of sustainable development the Bangladesh digitalization program runs into some grave questions. The paper points out that ethics as a strongly endogenous force in development is indispensable to keep in view the simultaneity of attaining growth and social justice. These targets are variously manifested in different sectors an...

  7. Digital Leadership

    OpenAIRE

    Zupanzic, Tadeja; Verbeke, Johan; Achten, Henri; Herneoja, Aulikki

    2016-01-01

    Leadership is an important quality in organisations. Leadership is needed to introduce change and innovation. In our opinion, in architectural and design practices, the role of leadership has not yet been sufficiently studied, especially when it comes to the role of digital tools and media. With this paper, we intend to initiate a discussion in the eCAADe community to reflect and develop ideas in order to develop digital leadership skills amongst the membership. This paper introduces some imp...

  8. Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Wan; Lee, Byung Do [Wonkwang University College of Medicine, Iksan (Korea, Republic of)

    2003-03-15

    The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p>0.05). These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  9. Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries

    International Nuclear Information System (INIS)

    Lee, Wan; Lee, Byung Do

    2003-01-01

    The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p>0.05). These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  10. A single injection technique for subtraction of blood background in 131I-hippuran renograms

    International Nuclear Information System (INIS)

    Rutland, M.D.

    1979-01-01

    A method of subtracting blood background during probe-renography is presented which does not require a prior injection of RIHSA and which produces results approximately 11% higher than the RIHSA method. The new method treats the renogram up to two-and-a-half minutes as a combination of a fraction of the blood curve and a fraction of the integral of the blood curve. Analysis of the data, using either a computer or a programmed calculator, enables these two fractions to be calculated, hence producing the 'background subtraction factor' and the 'uptake constant'. (author)

  11. Higgs boson production in association with a jet using jettiness subtraction

    Directory of Open Access Journals (Sweden)

    Radja Boughezal

    2015-09-01

    Full Text Available We use the recently proposed jettiness-subtraction scheme to provide the complete calculation of Higgs boson production in association with a jet in hadronic collisions through next-to-next-to-leading order in perturbative QCD. This method exploits the observation that the N-jettiness event-shape variable completely describes the singularity structure of QCD when final-state colored particles are present. Our results are in agreement with a recent computation of the gg and qg partonic initial states based on sector-improved residue subtraction. We present phenomenological results for both fiducial cross sections and distributions at the LHC.

  12. Similarity renormalization group evolution of N N interactions within a subtractive renormalization scheme

    Directory of Open Access Journals (Sweden)

    Durães F.O.

    2010-04-01

    Full Text Available We apply the similarity renormalization group (SRG approach to evolve a nucleon-nucleon (N N interaction in leading-order (LO chiral effective field theory (ChEFT, renormalized within the framework of the subtracted kernel method (SKM. We derive a fixed-point interaction and show the renormalization group (RG invariance in the SKM approach. We also compare the evolution of N N potentials with the subtraction scale through a SKM RG equation in the form of a non-relativistic Callan-Symanzik (NRCS equation and the evolution with the similarity cutoff through the SRG transformation.

  13. Parathyroid localizlation by 201Tl-99mTc subtraction scintigraphy

    International Nuclear Information System (INIS)

    Rademaker, P.; Meijer, S.; Piers, D.A.

    1990-01-01

    Subtraction scintigraphy with 201 Tl and 99m Tc for parathyroid localization was performed preoperatively in 13 patients with chronic renal failure and secondary hyperparathyroidism. Twenty of the 37 examined pathological glands were predicted correctly (sensitivity 54%). In 3 patients with recurrent hyperparathyroidism after surgery all pathological glands found at second operation had been detected correctly by subtraction scintigraphy. We conclude that this localization method has a limited value when used prior to first neck exploration in secondary hyperparathyroidism. In persistent hyperparathyroidism after surgery it may play a useful role in localizing missed and ectopic glands. (author)

  14. Digital substraction angiography in aortic dissection

    International Nuclear Information System (INIS)

    Khadzhidekov, V.; Mircheva, M.; Genov, P.

    1993-01-01

    Regardless of the technical progress in new noninvasive methods, aortography is still regarded as a method providing the necessary information for cases of aortic dissection, especially those requiring emergency operative management. Twenty-four DS-aortographies of patients suspected for aortic dissection are reviewed. Intraarterial DSA is less hazardous owing to the reduced flow rate and quantity of contrast medium required. The relative share of inadequate images is rather high, and conventional cineaortography cannot be invariably replaced by the digital subtracted one. However, angiographic examination in cases suspected for aortic dissection may start with intraarterial digital substraction, and provided the latter proves inconclusive, conventional cineaortography may be resorted to. 6 refs., 3 figs. (orig.)

  15. Perceiving fingers in single-digit arithmetic problems

    Directory of Open Access Journals (Sweden)

    Ilaria eBerteletti

    2015-03-01

    Full Text Available In this study, we investigate in children the neural underpinnings of finger representation and finger movement involved in single-digit arithmetic problems. Evidence suggests that finger representation and finger-based strategies play an important role in learning and understanding arithmetic. Because different operations rely on different networks, we compared activation for subtraction and multiplication problems in independently localized finger somatosensory and motor areas and tested whether activation was related to skill. Brain activations from children between 8 and 13 years of age revealed that only subtraction problems significantly activated finger motor areas, suggesting reliance on finger-based strategies. In addition, larger subtraction problems yielded greater somatosensory activation than smaller problems, suggesting a greater reliance on finger representation for larger numerical values. Interestingly, better performance in subtraction problems was associated with lower activation in the finger somatosensory area. Our results support the importance of fine-grained finger representation in arithmetical skill and are the first neurological evidence for a functional role of the somatosensory finger area in proficient arithmetical problem solving, in particular for those problems requiring quantity manipulation. From an educational perspective, these results encourage investigating whether different finger-based strategies facilitate arithmetical understanding and encourage educational practices aiming at integrating finger representation and finger-based strategies as a tool for instilling stronger numerical sense.

  16. Digital circuit for the introduction and later removal of dither from an analog signal

    Science.gov (United States)

    Borgen, Gary S.

    1994-05-01

    An electronics circuit is presented for accurately digitizing an analog audio or like data signal into a digital equivalent signal by introducing dither into the analog signal and then subsequently removing the dither from the digitized signal prior to its conversion to an analog signal which is a substantial replica of the incoming analog audio or like data signal. The electronics circuit of the present invention is characterized by a first pseudo-random number generator which generates digital random noise signals or dither for addition to the digital equivalent signal and a second pseudo-random number generator which generates subtractive digital random noise signals for the subsequent removal of dither from the digital equivalent signal prior its conversion to the analog replica signal.

  17. Intravenous drugs infusion safety through smart pumps

    Directory of Open Access Journals (Sweden)

    C. Gómez-Baraza

    2014-07-01

    Full Text Available Objective: To analyze the role of smart infusion pumps in reducing errors related with the administration of intravenous medications. Method: Retrospective, observational study analyzing the implementation of a system with smart intravenous infusion pumps (Hospira MedNetTM and the role of the safety system for the detection of errors during the administration of drugs, sera, and blood. We included infusions administered at the day-care hospitals of hematology, oncology, rheumatology, and oncopediatrics. We analyzed adherence to the safety system, the number of programming errors detected, the commonly implicated drugs in these errors, and improvement actions. Results: During the study period, 120 smart pumps were implemented and data on 70,028 infusions were gathered. The rate of adherence to the safety program was 62.30% in hematology (6,887 infusions, 60,30% in oncology (28,127 infusions, 46,50% in rheumatology (1,950 infusions and 1.8% in oncopediatrics (139 infusions. 3,481 out of the established limits programming alerts were generated by the pumps: 2,716 of relative limit and 765 of absolute limit. En 807 infusions (2.17%, errors that could have had consequences for the patients could be prevented. These findings allowed implementing a series of strategies aimed at minimizing these errors in the future. Conclusions: The Hospira MedNetTM system detects deviations from the established protocols of intravenous infusion, preventing in this way potential adverse events for the patients. It also allows establishing correction measures and implementing the improvement strategies.

  18. Effect of intravenous lipid on human pancreatic secretion.

    Science.gov (United States)

    Edelman, K; Valenzuela, J E

    1983-11-01

    Parenteral alimentation, including intravenous fat, is sometimes used in the treatment of patients with pancreatitis, although the effect of intravenous fat on human pancreatic secretion has not been systematically studied. Intravenous fat, however, has been shown to stimulate pancreatic protein secretion in the dog. The purpose of these studies was to clarify the effect of intravenous fat on human pancreatic secretion. Pancreatic secretion was assessed by measurement of enzymes and bicarbonate in duodenal aspirate collected via a double-lumen tube from 6 healthy volunteers. Four studies were randomly conducted on different days. On day 1, graded concentrations of Intralipid (5%, 10%, and 20%) were given intravenously for 1 h each, while secretin (8.2 pmol . kg-1 . h-1) was given as a background. On day 2, the same doses of Intralipid were infused intravenously without secretin. On day 3, the same doses of Intralipid were perfused into the intestine, and, finally, on day 4, 20% Intralipid was given by intestinal infusion for 2 h while 10% Intralipid was infused intravenously during the second hour. Significant stimulation of enzyme secretion was observed only during the infusion of fat into the intestine, not after intravenous infusion at any concentration. Pancreatic enzyme secretion, stimulated by intraintestinal fat, was not significantly modified by simultaneous intravenous lipid infusion. We conclude that since intravenous fat does not stimulate pancreatic secretion, its use in conditions where pancreatic stimulation is undesirable appears safe.

  19. Computer processing techniques in digital radiography research

    International Nuclear Information System (INIS)

    Pickens, D.R.; Kugel, J.A.; Waddill, W.B.; Smith, G.D.; Martin, V.N.; Price, R.R.; James, A.E. Jr.

    1985-01-01

    In the Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, and the Center for Medical Imaging Research, Nashville, TN, there are several activities which are designed to increase the information available from film-screen acquisition as well as from direct digital acquisition of radiographic information. Two of the projects involve altering the display of images after acquisition, either to remove artifacts present as a result of the acquisition process or to change the manner in which the image is displayed to improve the perception of details in the image. These two projects use methods which can be applied to any type of digital image, but are being implemented with images digitized from conventional x-ray film. One of these research endeavors involves mathematical alteration of the image to correct for motion artifacts or registration errors between images that will be subtracted. Another applies well-known image processing methods to digital radiographic images to improve the image contrast and enhance subtle details in the image. A third project involves the use of dual energy imaging with a digital radiography system to reconstruct images which demonstrate either soft tissue details or the osseous structures. These projects are discussed in greater detail in the following sections of this communication

  20. Screening and identification of lung cancer metastasis-related genes by suppression subtractive hybridization.

    Science.gov (United States)

    Liu, Jiewei; Zhong, Xiaorong; Li, Juan; Liu, Baoxing; Guo, Shanxian; Chen, Jun; Tan, Qingwei; Wang, Qin; Ma, Wei; Wu, Zhihao; Wang, Haisu; Hou, Mei; Zhang, Hong-Tao; Zhou, Qinghua

    2012-08-01

      Lung cancer metastasis is a complicated process in which multiple stages and multiple genes are involved. There is an urgent need to use new molecular biology techniques to get more systematic information and have a general idea of the molecular events that take place in lung cancer metastasis. The object of this study was to construct the subtracted cDNA libraries of different metastatic potential lung cancer cell lines, NL9980 and L9981, which were established and screened from human lung large cell carcinoma cell line, WCQH-9801.   The forward and reverse subtracted cDNA libraries were constructed in the large cell lung cancer cell lines NL9980 and L9981 with the same heredity background but different metastatic potential, by suppression subtractive hybridization (SSH). The positive clones were preliminarily screened by blue-white colony and precisely identified by PCR. The forward and reverse subtracted libraries were screened and identified by dot blot so as to obtain the clones corresponding to gene segments with differential expression. DNA sequencing was performed to analyze the sequences of differential expression segments, which were then searched and compared using the Basic Local Alignment Search Tool from The National Center for Biotechnology Information NCBI BLAST tools. Quantitative real-time reverse transcription polymerase chain reaction (RT-PCR) and western blotting were performed to confirm the differential expressed genes both on RNA and protein levels.   The forward and reverse subtracted cDNA libraries of the different large cell lung cancer cell lines with metastatic potential were successfully constructed. With blue-white colony and dot blot, 307 positive clones in the forward subtracted library and 78 positive clones in the reverse subtracted library were obtained. Fifty-five clones were successfully sequenced in the forward subtracted library while 31 clones were successfully sequenced in the reverse subtracted library. One new