WorldWideScience

Sample records for intravenous contrast agent

  1. Contrast agent choice for intravenous coronary angiography

    International Nuclear Information System (INIS)

    Zeman, H.D.; Siddons, D.P.

    1989-01-01

    The screening of the general population for coronary artery disease would be practical if a method existed for visualizing the extent of occlusion after an intravenous injection of contrast agent. Measurements performed with monochromatic synchrotron radiation x-rays and an iodine containing contrast agent at the Stanford Synchrotron Radiation Laboratory have shown that such an intravenous angiography procedure would be possible with an adequately intense monochromatic x-ray source. Because of the size and cost of synchrotron radiation facilities it would be desirable to make the most efficient use of the intensity available, while reducing as much as possible the radiation dose experienced by the patient. By choosing contrast agents containing elements with a higher atomic number than iodine, it is possible to both improve the image quality and reduce the patient radiation dose, while using the same synchrotron source. By using Si monochromator crystals with a small mosaic spread, it is possible to increase the x-ray flux available for imaging by over an order of magnitude, without any changes in the storage ring or wiggler magnet. The most critical imaging task for intravenous coronary angiography utilizing synchrotron radiation x-rays is visualizing a coronary artery through the left ventricle or aorta which also contains a contrast agent. Calculations have been made of the signal to noise ratio expected for this imaging task for various contrast agents with atomic numbers between that of iodine and bismuth

  2. Contrast agent choice for intravenous coronary angiography

    International Nuclear Information System (INIS)

    Zeman, H.D.; Siddons, D.P.

    1990-01-01

    The screening of the general population for coronary artery disease would be practical if a method existed for visualizing the extent of occlusion after an intravenous injection of contrast agent. Measurements performed with monochromatic synchrotron radiation X-rays and an iodine-containing contrast agent at the Stanford Synchrotron Radiation Laboratory have shown that such an intravenous angiography procedure would be possible with an adequately intense monochromatic X-ray source. Because of the size and cost of synchrotron radiation facilities it would be desirable to make the most efficient use of the intensity available, while reducing as much as possible the radiation dose experienced by the patient. By choosing contrast agents containing elements with a higher atomic number than iodine, it is possible to both improve the image quality and reduce the patient radiation dose, while using the same synchrotron radiation source. By using Si monochromator crystals with a small mosaic spread, it is possible to increase the X-ray flux available for imaging by over an order of magnitude, without any changes in the storage ring or wiggler magnet. The most critical imaging task for intravenous coronary angiography utilizing synchrotron radiation X-rays is visualizing a coronary artery through the left ventricle or aorta which also contain contrast agent. Calculations have been made of the signal to noise ratio expected for this imaging task for various contrast agents with atomic numbers between that of iodine and bismuth. The X-ray energy spectrum of the X-17 superconduction wiggler beam line at the National Synchrotron Light Source at Brookhaven National Laboratory has been used for these calculations. Both perfect Si crystals and Si crystals with a small mosaic spread are considered as monochromators. Contrast agents containing Gd or Yb seem to have about the optimal calculated signal to noise ratio. (orig./HSI)

  3. Contrast-enhanced voiding urosonography phantom study: intravenous iodinated and gadolinium-based contrast agents may cause false-negative results in assessment of vesicoureteral reflux in children

    International Nuclear Information System (INIS)

    Veldhoen, Simon; Sauer, Alexander; Gassenmaier, Tobias; Petritsch, Bernhard; Herz, Stefan; Blanke, Philipp; Bley, Thorsten A.; Wirth, Clemens; Derlin, Thorsten

    2015-01-01

    Contrast-enhanced voiding urosonography (ce-VUS) is commonly requested simultaneously to other diagnostic imaging necessitating intravenous contrast agents. To date there is limited knowldedge about intravesical interactions between different types of contrast agents. To assess the effect of excreted intravenous iodinated and gadolinium-based contrast agents on the intravesical distribution of ultrasound contrast within contrast-enhanced voiding urosonography. Iodinated (iomeprol, iopamidol) and gadolinium-based (gadoterate meglumine) contrast agents were diluted to bladder concentration and injected into balloons filled with saline solution. CT scans were performed to assess the contrast distribution in these phantoms. Regions of interest were placed at the top and bottom side of each balloon and Hounsfield units (HU) were measured. Three other balloons were filled with saline solution and contrast media likewise. The ultrasound contrast agent sulphur hexafluoride was added and its distribution was assessed using sonography. MDCT scans showed a separation of two liquid layers in all bladder phantoms with the contrast layers located at the bottom and the saline solution at the top. Significant differences of the HU measurements at the top and bottom side were observed (P < 0.001-0.007). Following injection of ultrasound contrast agent, US showed its distribution exclusively among the saline solution. False-negative results of contrast-enhanced voiding urosonography may occur if it is performed shortly after imaging procedures requiring intravenous contrast. (orig.)

  4. Intravenous carbon dioxide as an echocardiographic contrast agent

    NARCIS (Netherlands)

    R.S. Meltzer (Richard); P.W.J.C. Serruys (Patrick); P.G. Hugenholtz (Paul); J.R.T.C. Roelandt (Jos)

    1981-01-01

    textabstractIntravenous carbon dioxide (CO2) was employed to cause echocardiographic contrast in 40 patients. One to 3 cc of medically pure CO2 were agitated with 5 to 8 cc of 5% dextrose in water and rapidly injected into an upper extremity vein. Contrast was obtained in all patients. In 33

  5. Complications from the use of intravenous gadolinium-based contrast agents for magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Elias Junior, Jorge; Santos, Antonio Carlos dos; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Koenigkam-Santos, Marcel [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas. Centro de Ciencias das Imagens e Fisica Medica]. E-mail: jejunior@fmrp.usp.br

    2008-07-15

    Gadolinium-based contrast agents are much safer than the iodinated ones; however complications may occur and should be recognized for appropriate orientation and management. The total incidence of adverse reactions to contrast agents in magnetic resonance imaging ranges between 2% and 4%. Cases of severe acute reactions to gadolinium, such as laryngospasm and anaphylactic shock, are rare. Chronic complications secondary to the use of gadolinium also can occur and, recently an association between its use and a rare dermatologic disease occurring in patients with renal failure has been reported. Nephrogenic systemic fibrosis was the subject of an official health notification issued by the American Food and Drug Administration. This progressive disease is characterized by hardened skin with fibrotic nodules and plaques which may involve other parts of the body. Patients who have been affected by this disorder presented chronic renal failure, with metabolic acidosis and had been submitted to magnetic resonance angiography, probably involving exposure to large amounts of intravenous paramagnetic contrast. This review is aimed at presenting a succinct description of the gadolinium-based contrast agent types, possible secondary complications, their preventive measures and management. (author)

  6. Choice of intravenous contrast material for CT

    International Nuclear Information System (INIS)

    Cohen, M.D.; Herman, E.; Herron, D.; White, S.T.; Smith, J.A.; Cory, D.A.

    1989-01-01

    For CT, minor side effects (e.g., nausea, vomiting, pain) following intravenous administration of contrast medium may degrade image quality by causing patient motion or by delaying scanning. The objective of this study was to see if nonionic contrast agents offer advantages in reducing the incidence of such side effects. One hundred five pediatric patients randomly received iohexol (Omnipaque), Iopamidol (Isovue), or diatrizoate sodium (Hypaque). Contrast medium was given in doses of 2 mL/kg body weight (300 mg of iodine per milliliter). The results are presented in the paper

  7. Contrast-enhanced peripheral MRA. Technique and contrast agents

    International Nuclear Information System (INIS)

    Nielsen, Yousef W.; Thomsen, Henrik S.

    2012-01-01

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  8. [Complications due to contrast agent administration: what has been confirmed in prevention?].

    Science.gov (United States)

    Schönenberger, E; Mühler, M; Dewey, M

    2010-12-01

    Computed tomography (CT) and magnetic resonance imaging (MRI) have been evaluated by internists to be the most important medical innovations. Often, intravenous contrast agent administration is required for answering the clinical questions to CT and MRI. In this review we present an overview of the most common and most important aspects that need to be considered prior to intravenous contrast agent administration. We discuss aspects of renal impairment (contrast-induced nephropathy, nephrogenic systemic fibrosis), allergy-like reactions, hyperthyroidism, and pregnancy and breast-feeding.

  9. The behavior after intravenous injection in mice of multiwalled carbon nanotube / Fe3O4 hybrid MRI contrast agents.

    Science.gov (United States)

    Wu, Huixia; Liu, Gang; Zhuang, Yeming; Wu, Dongmei; Zhang, Haoqiang; Yang, Hong; Hu, He; Yang, Shiping

    2011-07-01

    Fe(3)O(4) nanoparticles were in situ loaded on the surface of multiwalled carbon nanotubes (MWCNTs) by a solvothermal method using diethylene glycol and diethanolamine as solvents and complexing agents. The as-prepared MWCNT/Fe(3)O(4) hybrids exhibited excellent hydrophilicity, superparamagnetic property at room temperature, and a high T(2) relaxivity of 175.5 mM(-1) s(-1) in aqueous solutions. In vitro experiments revealed that MWCNT/Fe(3)O(4) had an excellent magnetic resonance imaging (MRI) enhancement effect on cancer cells, and importantly, they displayed low cytotoxicity and neglectable hemolytic activity. After intravenous administration, the T(2)-weighted MRI signal in the liver and spleen of mice decreased significantly, suggesting the potential application of the hybrids as MRI contrast agents. The organ biodistribution studies, histological analyses and elimination investigations showed that the hybrids were uptaken by the liver, lung and spleen after intravenous injection, and could be excreted from the liver and kidney. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Avascular necrosis (AVN) of the proximal fragment in scaphoid nonunion: Is intravenous contrast agent necessary in MRI?

    International Nuclear Information System (INIS)

    Schmitt, R.; Christopoulos, G.; Wagner, M.; Krimmer, H.; Fodor, S.; Schoonhoven, J. van; Prommersberger, K.J.

    2011-01-01

    Purpose: The purpose of this prospective study is to assess the diagnostic value of intravenously applied contrast agent for diagnosing osteonecrosis of the proximal fragment in scaphoid nonunion, and to compare the imaging results with intraoperative findings. Materials and methods: In 88 patients (7 women, 81 men) suffering from symptomatic scaphoid nonunion, preoperative MRI was performed (coronal PD-w FSE fs, sagittal-oblique T1-w SE nonenhanced and T1-w SE fs contrast-enhanced, sagittal T2*-w GRE). MRI interpretation was based on the intensity of contrast enhancement: 0 = none, 1 = focal, 2 = diffuse. Intraoperatively, the osseous viability was scored by means of bleeding points on the osteotomy site of the proximal scaphoid fragment: 0 = absent, 1 = moderate, 2 = good. Results: Intraoperatively, 17 necrotic, 29 compromised, and 42 normal proximal fragments were found. In nonenhanced MRI, bone viability was judged necrotic in 1 patient, compromised in 20 patients, and unaffected in 67 patients. Contrast-enhanced MRI revealed 14 necrotic, 21 compromised, and 53 normal proximal fragments. Judging surgical findings as the standard of reference, statistical analysis for nonenhanced MRI was: sensitivity 6.3%, specificity 100%, positive PV 100%, negative PV 82.6%, and accuracy 82.9%; statistics for contrast-enhanced MRI was: sensitivity 76.5%, specificity 98.6%, positive PV 92.9%, negative PV 94.6%, and accuracy 94.3%. Sensitivity for detecting avascular proximal fragments was significantly better (p < 0.001) in contrast-enhanced MRI in comparison to nonenhanced MRI. Conclusion: Viability of the proximal fragment in scaphoid nonunion can be significantly better assessed with the use of contrast-enhanced MRI as compared to nonenhanced MRI. Bone marrow edema is an inferior indicator of osteonecrosis. Application of intravenous gadolinium is recommended for imaging scaphoid nonunion.

  11. Avascular necrosis (AVN) of the proximal fragment in scaphoid nonunion: Is intravenous contrast agent necessary in MRI?

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, R., E-mail: schmitt.radiologie@herzchirurgie.de [Department of Diagnostic and Interventional Radiology, Cardiovascular Center, Bad Neustadt an der Saale (Germany); Christopoulos, G.; Wagner, M. [Department of Diagnostic and Interventional Radiology, Cardiovascular Center, Bad Neustadt an der Saale (Germany); Krimmer, H. [Department of Hand Surgery, Cardiovascular Center, Bad Neustadt an der Saale (Germany); Fodor, S. [Department of Diagnostic and Interventional Radiology, Cardiovascular Center, Bad Neustadt an der Saale (Germany); Schoonhoven, J. van; Prommersberger, K.J. [Department of Hand Surgery, Cardiovascular Center, Bad Neustadt an der Saale (Germany)

    2011-02-15

    Purpose: The purpose of this prospective study is to assess the diagnostic value of intravenously applied contrast agent for diagnosing osteonecrosis of the proximal fragment in scaphoid nonunion, and to compare the imaging results with intraoperative findings. Materials and methods: In 88 patients (7 women, 81 men) suffering from symptomatic scaphoid nonunion, preoperative MRI was performed (coronal PD-w FSE fs, sagittal-oblique T1-w SE nonenhanced and T1-w SE fs contrast-enhanced, sagittal T2*-w GRE). MRI interpretation was based on the intensity of contrast enhancement: 0 = none, 1 = focal, 2 = diffuse. Intraoperatively, the osseous viability was scored by means of bleeding points on the osteotomy site of the proximal scaphoid fragment: 0 = absent, 1 = moderate, 2 = good. Results: Intraoperatively, 17 necrotic, 29 compromised, and 42 normal proximal fragments were found. In nonenhanced MRI, bone viability was judged necrotic in 1 patient, compromised in 20 patients, and unaffected in 67 patients. Contrast-enhanced MRI revealed 14 necrotic, 21 compromised, and 53 normal proximal fragments. Judging surgical findings as the standard of reference, statistical analysis for nonenhanced MRI was: sensitivity 6.3%, specificity 100%, positive PV 100%, negative PV 82.6%, and accuracy 82.9%; statistics for contrast-enhanced MRI was: sensitivity 76.5%, specificity 98.6%, positive PV 92.9%, negative PV 94.6%, and accuracy 94.3%. Sensitivity for detecting avascular proximal fragments was significantly better (p < 0.001) in contrast-enhanced MRI in comparison to nonenhanced MRI. Conclusion: Viability of the proximal fragment in scaphoid nonunion can be significantly better assessed with the use of contrast-enhanced MRI as compared to nonenhanced MRI. Bone marrow edema is an inferior indicator of osteonecrosis. Application of intravenous gadolinium is recommended for imaging scaphoid nonunion.

  12. Avascular necrosis (AVN) of the proximal fragment in scaphoid nonunion: is intravenous contrast agent necessary in MRI?

    Science.gov (United States)

    Schmitt, R; Christopoulos, G; Wagner, M; Krimmer, H; Fodor, S; van Schoonhoven, J; Prommersberger, K J

    2011-02-01

    The purpose of this prospective study is to assess the diagnostic value of intravenously applied contrast agent for diagnosing osteonecrosis of the proximal fragment in scaphoid nonunion, and to compare the imaging results with intraoperative findings. In 88 patients (7 women, 81 men) suffering from symptomatic scaphoid nonunion, preoperative MRI was performed (coronal PD-w FSE fs, sagittal-oblique T1-w SE nonenhanced and T1-w SE fs contrast-enhanced, sagittal T2*-w GRE). MRI interpretation was based on the intensity of contrast enhancement: 0 = none, 1 = focal, 2 = diffuse. Intraoperatively, the osseous viability was scored by means of bleeding points on the osteotomy site of the proximal scaphoid fragment: 0=absent, 1 = moderate, 2 = good. Intraoperatively, 17 necrotic, 29 compromised, and 42 normal proximal fragments were found. In nonenhanced MRI, bone viability was judged necrotic in 1 patient, compromised in 20 patients, and unaffected in 67 patients. Contrast-enhanced MRI revealed 14 necrotic, 21 compromised, and 53 normal proximal fragments. Judging surgical findings as the standard of reference, statistical analysis for nonenhanced MRI was: sensitivity 6.3%, specificity 100%, positive PV 100%, negative PV 82.6%, and accuracy 82.9%; statistics for contrast-enhanced MRI was: sensitivity 76.5%, specificity 98.6%, positive PV 92.9%, negative PV 94.6%, and accuracy 94.3%. Sensitivity for detecting avascular proximal fragments was significantly better (p<0.001) in contrast-enhanced MRI in comparison to nonenhanced MRI. Viability of the proximal fragment in scaphoid nonunion can be significantly better assessed with the use of contrast-enhanced MRI as compared to nonenhanced MRI. Bone marrow edema is an inferior indicator of osteonecrosis. Application of intravenous gadolinium is recommended for imaging scaphoid nonunion. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  13. Apparition of iodinated contrast agents in twin neonatal gastrointestinal tracts after maternal contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Kato, Hiroki; Kanematsu, Masayuki; Kato, Zenichiro; Kondo, Naomi; Orii, Kenji E.; Morimoto, Masahiro

    2011-01-01

    We describe a case of the appearance of iodinated contrast agents in the same locations of twins' neonatal gastrointestinal tracts 1 day after maternal contrast-enhanced computed tomography (CT). The CT examination had been performed on the expectant mother for suspected deep venous thrombosis on the day previous to the twin delivery. At 23 h after the CT examination and after cesarean section, iodinated contrast agents appeared in the same place in the twins' neonatal gastrointestinal tracts, mainly in the ascending colon, on plain abdominal radiographs. Radiologists, obstetricians, and pediatricians should understand the mechanism of appearance of iodinated contrast agents in fetal gastrointestinal tracts when the expectant mother had been given iodinated contrast agents intravenously shortly before delivery. (author)

  14. Safety of ultrasound contrast agents in stress echocardiography.

    Science.gov (United States)

    Gabriel, Ruvin S; Smyth, Yvonne M; Menon, Venu; Klein, Allan L; Grimm, Richard A; Thomas, James D; Sabik, Ellen Mayer

    2008-11-01

    Definity and Optison are perflutren-based ultrasound contrast agents used in echocardiography. United States Food and Drug Administration warnings regarding serious cardiopulmonary reactions and death after Definity administration highlighted the limited safety data in patients who undergo contrast stress echocardiography. From 1998 and 2007, 2,022 patients underwent dobutamine stress echocardiography and 2,764 underwent exercise stress echocardiography with contrast at the Cleveland Clinic. The echocardiographic database, patient records, and the Social Security Death Index were reviewed for the timing and cause of death, severe adverse events, arrhythmias, and symptoms. Complication rates for contrast dobutamine stress echocardiography and exercise stress echocardiography were compared with those in a control group of 5,012 patients matched for test year and type who did not receive contrast. Ninety-five percent of studies were performed in outpatients. There were no differences in the rates of severe adverse events (0.19% vs 0.17%, p = 0.7), death within 24 hours (0% vs 0.04%, p = 0.1), cardiac arrest (0.04% vs 0.04%, p = 0.96), and sustained ventricular tachycardia (0.2% vs 0.1%, p = 0.32) between patients receiving and not receiving intravenous contrast, respectively. In conclusion, severe adverse reactions to intravenous contrast agents during stress echocardiography are uncommon. Contrast use does not add to the baseline risk for severe adverse events in patients who undergo stress echocardiography.

  15. Intravenous, contrast-enhanced MR colonography using air as endoluminal contrast agent: Impact on colorectal polyp detection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2012-02-01

    PURPOSE: To compare diagnostic accuracy and patient tolerance of MR colonography with intravenous contrast and luminal air (MRC) to conventional colonoscopy (CC). MATERIALS AND METHODS: IRB approval and written informed consent were obtained. Forty-six patients, both screening and symptomatic, underwent MRC followed by CC. The MRC technique employed 3D T1W spoiled gradient echo sequences performed after the administration of gadopenetate dimeglumine, with parallel imaging. The diagnostic accuracy and tolerance of patients for MRC was compared to CC. RESULTS: Twenty-four polyps were detected in eighteen patients with CC (5 polyps >\\/=10mm, 4 polyps 6-9mm, 15 polyps <\\/=5mm). MRC was 66.7% (12\\/18) sensitive and 96.4% (27\\/28) specific for polyp detection on a per-patient basis. When analyzed by polyp size, sensitivity and specificity of MRC was 100% (5\\/5) and 100% (19\\/19), respectively, for lesions greater than 10mm, 100% (4\\/4) and 100% (20\\/20) for lesions 6-9mm, and sensitivity of 20% (3\\/15) lesions less than 5mm. The sensitivity and specificity of MRC for detecting significant lesions (>6mm) was 100% (9\\/9) and 100% (15\\/15), respectively. Regarding tolerance of the exams, there were no significant differences between MRC and CC. Thirty-five percent (n=16) of patients preferred MRC as a future screening test compared to 33% (n=15) for CC. CONCLUSION: MRC using air as an intraluminal contrast agent is a feasible and well-tolerated technique for detecting colonic polyps >\\/=6mm in size. Further studies are warranted.

  16. Intravenous, contrast-enhanced MR colonography using air as endoluminal contrast agent: Impact on colorectal polyp detection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2010-12-03

    PURPOSE: To compare diagnostic accuracy and patient tolerance of MR colonography with intravenous contrast and luminal air (MRC) to conventional colonoscopy (CC). MATERIALS AND METHODS: IRB approval and written informed consent were obtained. Forty-six patients, both screening and symptomatic, underwent MRC followed by CC. The MRC technique employed 3D T1W spoiled gradient echo sequences performed after the administration of gadopenetate dimeglumine, with parallel imaging. The diagnostic accuracy and tolerance of patients for MRC was compared to CC. RESULTS: Twenty-four polyps were detected in eighteen patients with CC (5 polyps ≥10mm, 4 polyps 6-9mm, 15 polyps ≤5mm). MRC was 66.7% (12\\/18) sensitive and 96.4% (27\\/28) specific for polyp detection on a per-patient basis. When analyzed by polyp size, sensitivity and specificity of MRC was 100% (5\\/5) and 100% (19\\/19), respectively, for lesions greater than 10mm, 100% (4\\/4) and 100% (20\\/20) for lesions 6-9mm, and sensitivity of 20% (3\\/15) lesions less than 5mm. The sensitivity and specificity of MRC for detecting significant lesions (>6mm) was 100% (9\\/9) and 100% (15\\/15), respectively. Regarding tolerance of the exams, there were no significant differences between MRC and CC. Thirty-five percent (n=16) of patients preferred MRC as a future screening test compared to 33% (n=15) for CC. CONCLUSION: MRC using air as an intraluminal contrast agent is a feasible and well-tolerated technique for detecting colonic polyps ≥6mm in size. Further studies are warranted.

  17. Contrast amplification of the liver parenchyma in the computer tomogram by using intravenous and peroral biliary contrast media

    International Nuclear Information System (INIS)

    Justich, E.; Sager, W.D.; Dietrich, G.; Fotter, R.; Nedden, D. zur; Innsbruck Univ.

    1980-01-01

    If intravenous, biliary contrast media are used, a slight albeit specific enhancement of contrast of the liver parenchyma occurs with the applied dosage, which can be utilised in individual cases, for example for identifying isodense lesions. Contrast amplification by the peroral cholegraphic agent under examination, is insufficient for use in computer tomography of the liver. The use of biliary contrast media usually enables very good visualisation of the extrahepatic bile ducts. Attention is drawn to the possibility of pharmakokinetic studies by means of computer tomography. (orig.) [de

  18. Rare earth contrast agents in hepatic computed tomography

    International Nuclear Information System (INIS)

    Seltzer, S.E.

    1981-01-01

    Materials with atomic numbers ranging from the upper 50's to the lower 70's proved to have the highest computed tomography (CT) numbers when scanned at 120 kVp. Therefore, to produce particulate contrast agents possessing maximum radiopacity, suspensions of cerium oxide, gadolinium, and dysprosium oxides as well as silver iodide colloid were prepared. All 4 agents were selectively concentrated in the reticulo-endothelial system. The agents produced greater and longer opacification of the normal liver and larger liver-to-tumor differences in rabbits with hepatic tumors than did equivalent amounts of standard intravenous iodinated agents. Lesions as small as 5 mm were visible with CT. These materials have favorable characteristics as hepatic contrast agents, but their toxicity (LD 50 in mice = 5.4 g/kg for Ce) and long-term retention may limit clinical use. (Auth.)

  19. Nanodiamond-Manganese dual mode MRI contrast agents for enhanced liver tumor detection.

    Science.gov (United States)

    Hou, Weixin; Toh, Tan Boon; Abdullah, Lissa Nurrul; Yvonne, Tay Wei Zheng; Lee, Kuan J; Guenther, Ilonka; Chow, Edward Kai-Hua

    2017-04-01

    Contrast agent-enhanced magnetic resonance (MR) imaging is critical for the diagnosis and monitoring of a number of diseases, including cancer. Certain clinical applications, including the detection of liver tumors, rely on both T1 and T2-weighted images even though contrast agent-enhanced MR imaging is not always reliable. Thus, there is a need for improved dual mode contrast agents with enhanced sensitivity. We report the development of a nanodiamond-manganese dual mode contrast agent that enhanced both T1 and T2-weighted MR imaging. Conjugation of manganese to nanodiamonds resulted in improved longitudinal and transverse relaxivity efficacy over unmodified MnCl 2 as well as clinical contrast agents. Following intravenous administration, nanodiamond-manganese complexes outperformed current clinical contrast agents in an orthotopic liver cancer mouse model while also reducing blood serum concentration of toxic free Mn 2+ ions. Thus, nanodiamond-manganese complexes may serve as more effective dual mode MRI contrast agent, particularly in cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Fatal anaphylactic reaction to intravenous gadobutrol, a gadolinium-based MRI contrast agent

    Directory of Open Access Journals (Sweden)

    Sabine Franckenberg, MD

    2018-02-01

    Full Text Available We present the rare case of a fatal anaphylactic reaction to gadobutrol, a magnetic resonance imaging contrast agent, in a 42-year-old man. The patient underwent elective magnetic resonance imaging for diagnostic clarification of a suspicious finding in the abdomen. The patient had undergone contrast-enhanced computed tomography previously without the occurrence of any adverse effects. Adverse drug reactions in gadobutrol have a very low prevalence of 0.32%-3.5%, with serious adverse drug reactions in <0.1%. There are only a few cases of fatal anaphylactoid reactions to gadolinium-based contrast agents in general. However, if an anaphylactoid reaction occurs, it can present itself with a fulminant course within minutes.

  1. Quantitative evaluation of contrast-enhanced ultrasound after intravenous administration of a microbubble contrast agent for differentiation of benign and malignant thyroid nodules: assessment of diagnostic accuracy.

    Science.gov (United States)

    Nemec, Ursula; Nemec, Stefan F; Novotny, Clemens; Weber, Michael; Czerny, Christian; Krestan, Christian R

    2012-06-01

    To investigate the diagnostic accuracy, through quantitative analysis, of contrast-enhanced ultrasound (CEUS), using a microbubble contrast agent, in the differentiation of thyroid nodules. This prospective study enrolled 46 patients with solitary, scintigraphically non-functional thyroid nodules. These patients were scheduled for surgery and underwent preoperative CEUS with pulse-inversion harmonic imaging after intravenous microbubble contrast medium administration. Using histology as a standard of reference, time-intensity curves of benign and malignant nodules were compared by means of peak enhancement and wash-out enhancement relative to the baseline intensity using a mixed model ANOVA. ROC analysis was performed to assess the diagnostic accuracy in the differentiation of benign and malignant nodules on CEUS. The complete CEUS data of 42 patients (31/42 [73.8%] benign and 11/42 [26.2%] malignant nodules) revealed a significant difference (P benign and malignant nodules. Furthermore, based on ROC analysis, CEUS demonstrated sensitivity of 76.9%, specificity of 84.8% and accuracy of 82.6%. Quantitative analysis of CEUS using a microbubble contrast agent allows the differentiation of benign and malignant thyroid nodules and may potentially serve, in addition to grey-scale and Doppler ultrasound, as an adjunctive tool in the assessment of patients with thyroid nodules. • Contrast-enhanced ultrasound (CEUS) helps differentiate between benign and malignant thyroid nodules. • Quantitative CEUS analysis yields sensitivity of 76.9% and specificity of 84.8%. • CEUS may be a potentially useful adjunct in assessing thyroid nodules.

  2. Connexin 43-targeted T1 contrast agent for MRI diagnosis of glioma.

    Science.gov (United States)

    Abakumova, Tatiana; Abakumov, Maxim; Shein, Sergey; Chelushkin, Pavel; Bychkov, Dmitry; Mukhin, Vladimir; Yusubalieva, Gaukhar; Grinenko, Nadezhda; Kabanov, Alexander; Nukolova, Natalia; Chekhonin, Vladimir

    2016-01-01

    Glioblastoma multiforme is the most aggressive form of brain tumor. Early and accurate diagnosis of glioma and its borders is an important step for its successful treatment. One of the promising targets for selective visualization of glioma and its margins is connexin 43 (Cx43), which is highly expressed in reactive astrocytes and migrating glioma cells. The purpose of this study was to synthesize a Gd-based contrast agent conjugated with specific antibodies to Cx43 for efficient visualization of glioma C6 in vivo. We have prepared stable nontoxic conjugates of monoclonal antibody to Cx43 and polylysine-DTPA ligands complexed with Gd(III), which are characterized by higher T1 relaxivity (6.5 mM(-1) s(-1) at 7 T) than the commercial agent Magnevist® (3.4 mM(-1) s(-1)). Cellular uptake of Cx43-specific T1 contrast agent in glioma C6 cells was more than four times higher than the nonspecific IgG-contrast agent, as detected by flow cytometry and confocal analysis. MRI experiments showed that the obtained agents could markedly enhance visualization of glioma C6 in vivo after their intravenous administration. Significant accumulation of Cx43-targeted contrast agents in glioma and the peritumoral zone led not only to enhanced contrast but also to improved detection of the tumor periphery. Fluorescence imaging confirmed notable accumulation of Cx43-specific conjugates in the peritumoral zone compared with nonspecific IgG conjugates at 24 h after intravenous injection. All these features of Cx43-targeted contrast agents might be useful for more precise diagnosis of glioma and its borders by MRI. Copyright © 2015 John Wiley & Sons, Ltd.

  3. The optimal use of contrast agents at high field MRI

    International Nuclear Information System (INIS)

    Trattnig, Siegfried; Pinker, Kathia; Ba-Ssalamah, Ahmed; Noebauer-Huhmann, Iris-Melanie

    2006-01-01

    The intravenous administration of a standard dose of conventional gadolinium-based contrast agents produces higher contrast between the tumor and normal brain at 3.0 Tesla (T) than at 1.5 T, which allows reducing the dose to half of the standard one to produce similar contrast at 3.0 T compared to 1.5 T. The assessment of cumulative triple-dose 3.0 T images obtained the best results in the detection of brain metastases compared to other sequences. The contrast agent dose for dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging at 3.0 T can be reduced to 0.1 mmol compared to 0.2 mmol at 1.5 T due to the increased susceptibility effects at higher magnetic field strengths. Contrast agent application makes susceptibility-weighted imaging (SWI) at 3.0 T clinically attractive, with an increase in spatial resolution within the same scan time. Whereas a double dose of conventional gadolinium-based contrast agents was optimal in SWI with respect to sensitivity and image quality, a standard dose of gadobenate dimeglumine, which has a two-fold higher T1-relaxivity in blood, produced the same effect. For MR-arthrography, optimized concentrations of gadolinium-based contrast agents are similar at 3.0 and 1.5 T. In summary, high field MRI requires the optimization of the contrast agent dose in different clinical applications. (orig.)

  4. New MR contrast agent

    International Nuclear Information System (INIS)

    Grossman, C.D.; Subramanian, G.; Schneider, R.; Szeverenyi, N.E.; Rosenbaum, A.M.; Gagne, G.; Tillapaugh-Fay, G.; Berlin, R.; Ritter-Hrncirik, C.; Yu, S.

    1990-01-01

    This paper evaluates an MR contrast agent-meglumine tris-(2,6-dicarboxypyridine) gadolinium (III) or gadolinium dipicolinate (Gd-DPC)-produced in-house. Rats were anesthetized with pentobarbital. For renal imaging, bowel motion artifact was minimized with glucagon (0.014 mg/kg, intravenous (IV)). Enhanced images were generated on a 2-T chemical shift imaging system with a 31-cm horizontal bore magnet after IV injection of Gd-DPC (100 μM/kg). Coronal sections of the kidneys and sagittal sections of the brain, 2 mm thick, were made. Six to eight excitations and 128 or 356 phase-encoding steps were used for each image. Control animals were injected with equivalent doses of gadopentetate dimeglumine

  5. PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients

    DEFF Research Database (Denmark)

    Berthelsen, A K; Holm, S; Loft, A

    2005-01-01

    PURPOSE: If the CT scan of a combined PET/CT study is performed as a full diagnostic quality CT scan including intravenous (IV) contrast agent, the quality of the joint PET/CT procedure is improved and a separate diagnostic CT scan can be avoided. CT with IV contrast can be used for PET attenuation...... correction, but this may result in a bias in the attenuation factors. The clinical significance of this bias has not been established. Our aim was to perform a prospective clinical study where each patient had CT performed with and without IV contrast agent to establish whether PET/CT with IV contrast can...... scans without, and then with contrast agent, followed by an 18F-fluorodeoxyglucose whole-body PET scan. The CT examinations were performed with identical parameters on a GE Discovery LS scanner. The PET data were reconstructed with attenuation correction based on the two CT data sets. A global...

  6. Neuroimaging: do we really need new contrast agents for MRI?

    International Nuclear Information System (INIS)

    Roberts, T.P.L.; Chuang, N.; Roberts, H.C.

    2000-01-01

    The use of exogenous contrast media in magnetic resonance imaging of the brain has brought dramatic improvement in the sensitivity of detection and delineation of pathological structures, such as primary and metastatic brain tumors, inflammation and ischemia. Disruption of the blood brain barrier leads to accumulation of the intravenously injected contrast material in the extravascular space, leading to signal enhancement. Magnetic resonance angiography benefits from T 1 -shortening effects of contrast agent, improving small vessel depiction and providing vascular visualization even in situations of slow flow. High speed dynamic MRI after bolus injection of contrast media allows tracer kinetic modeling of cerebral perfusion. Progressive enhancement over serial post-contrast imaging allows modeling of vascular permeability and thus quantitative estimation of the severity of blood brain barrier disruption. With such an array of capabilities and ever improving technical abilities, it seems that the role of contrast agents in MR neuroimaging is established and the development of new agents may be superfluous. However, new agents are being developed with prolonged intravascular residence times, and with in-vivo binding of ever-increasing specificity. Intravascular, or blood pool, agents are likely to benefit magnetic resonance angiography of the carotid and cerebral vessels; future agents may allow the visualization of therapeutic drug delivery, the monitoring of, for example, gene expression, and the imaging evaluation of treatment efficacy. So while there is a substantial body of work that can be performed with currently available contrast agents, especially in conjunction with optimized image acquisition strategies, post processing, and mathematical analysis, there are still unrealized opportunities for novel contrast agent introduction, particularly those exploiting biological specificity. This article reviews the current use of contrast media in magnetic resonance

  7. Informed consent for the administration of an intravenous contrast agent: importance and determinants of patient refusal

    International Nuclear Information System (INIS)

    Martel, J.; Garcia-Diaz, J. D.

    1999-01-01

    We proposed to determine the proportion of patients who refuse to undergo intravenous contrast administration and the factors that influence their refusal. Our series consisted of 442 patients who were supposed to undergo imaging studies involving the intravenous injection of an iodine contrast. In a personal interview, the patients were issued a questionnaire specifically designed for this study. The following parameters were recorded: sex, age, inpatient or outpatient status, medical history available, person who informed them about the procedure, person signing the informed consent (patient or other) , highest academic degree, attitude toward receiving the information and degree of concern after reading and signing the consent form. In our series 8.6% of the patients (95% confidence interval: 6-11.2) refused to sign the informed consent form. In addition, there were a number of patients who delayed the procedure or hindered the daily work schedule by some other means. When the relationship between each of the variables studied and refusal to sign the consent form was assessed, significant associations were observed between the latter and the academic level of the patient, his or her degree of concern and having received the information from a trained person. There was also a nearly significant trend toward the association between refusal and the patient's background. Relatively few patients refuse to sign the informed consent to receive intravenous contrast administration but this negative decision interferes with the health care practice. It is possible to identify certain correctable factors that influence the patient in this respect. (Author) 13 refs

  8. Intravenous contrast-enhanced sonography in children and adolescents – a single center experience

    Directory of Open Access Journals (Sweden)

    Martin Stenzel

    2013-06-01

    Full Text Available Compared to adult patients, ultrasonography in children and adolescents is much more common, due to lack of ionizing radiation, and its wide availability. With the introduction of contrast-media for use in ultrasonography, one major drawback of the method could be overcome. In Europe, SonoVue® is the only widely available agent, which due to improved stability makes it possible to image normal and diseased tissue perfusion and vascularization with high accuracy. Inability to hold the breath and voluntary body movement of the patient is less of an obstacle compared to color Doppler techniques and makes the method very attractive for use in children, which, depending on age, may not be very cooperative. Use of intravenous contrast-medium in minors is currently very limited for several reasons: availability, lack of recommendation in national and international guidelines, and lack of official licensing. The article will touch medical indications, technique, safety considerations, and perspective of intravenous use of contrast-media in children and adolescents, including data from a 6-year period in 37 patients. Purpose: The purpose of the study was to collect data on ultrasonographic examinations, expanded by intravenous administration of the contrast agent SonoVue® in children and adolescents. Besides assessing diagnostic yield, data on adverse medication effects was collected. Materials and methods: The study includes contrast-enhanced ultrasound examinations in 37 children at a single institution. Indications for the examinations were tumor lesions, infections, traumatic organ injuries, and parenchymal organ ischemia. Parents of the patients and adolescent patients were informed about the off-label use of the contrast agent. Thirty-nine examinations were performed, the average age of the patient was 11.1 years (range 1 7/ 12 to 17 11/ 12 years. Results: All of the examinations yielded additional diagnostic value, always expanding results

  9. Angiographic CT with intravenous contrast agent application for monitoring of intracranial flow diverting stents

    International Nuclear Information System (INIS)

    Saake, Marc; Struffert, Tobias; Goelitz, Philipp; Ott, Sabine; Doerfler, Arnd; Seifert, Frank; Ganslandt, Oliver

    2012-01-01

    Intracranial flow diverting devices are increasingly used to treat cerebral aneurysms. A reliable, non-invasive follow-up modality would be desirable. Our aim was to compare intra-arterial digital subtraction angiography (ia DSA) to angiographic computed tomography with intravenous contrast agent application (iv ACT) in the visualisation of flow diverting devices and aneurysm lumina. Follow-up monitoring by iv ACT (n = 36) and ia DSA (n = 25) in 14 patients treated with flow diverting devices for intracranial aneurysms was evaluated retrospectively. Images were evaluated by two neuroradiologists in anonymous consensus reading regarding the device deployment, wall apposition, neck coverage of the aneurysm, opacification of the vessel and device lumen, as well as the degree of aneurysm occlusion. Corresponding ia DSA and iv ACT images were scored identically in all patients regarding the stent deployment, wall apposition and neck coverage, as well as the degree of aneurysm occlusion and patency status of the device and parent artery. Opacification of the parent vessel lumen and perfused parts of the aneurysm was considered slightly inferior for iv ACT in comparison with ia DSA (seven of 36 cases), without impact on diagnosis. We demonstrated the feasibility and diagnostic value of iv ACT in follow-up imaging of intracranial flow diverting devices. Due to its high spatial resolution and non-invasive character, this novel technique might become a valuable imaging modality in these patients. (orig.)

  10. Intravenous Contrast Medium Administration for Computed Tomography Scan in Emergency: A Possible Cause of Contrast-Induced Nephropathy

    International Nuclear Information System (INIS)

    Sonhaye, Lantam; Kolou, Bérésa; Tchaou, Mazamaesso; Amadou, Abdoulatif; Assih, Kouméabalo; N'Timon, Bidamin; Adambounou, Kokou; Agoda-Koussema, Lama; Adjenou, Komlavi; N'Dakena, Koffi

    2015-01-01

    The goal of this study was to assess risk for CIN after CT Scan during an emergency and to identify risk factors for the patient. Prospective review of all patients admitted to the emergency room (ER) of the Teaching Hospital of Lomé (Togo) during a 2-year period. CIN was defined as an increase in serum creatinine by 0.5 mg/dL from admission after undergoing CT Scan with intravenous contrast. A total of 620 patients underwent a CT Scan in the emergency room using intravenous contrast and 672 patients took the CT Scan without intravenous contrast. Out of the patients who received intravenous contrast for CT Scan, three percent of them developed CIN during their admission. Moreover, upon discharge no patient had continued renal impairment. No patient required dialysis during their admission. The multivariate analysis of all patients who had serial creatinine levels (including those who did not receive any contrast load) shows no increased risk for acute kidney injury associated intravenous contrast (odds ratio = 0.619, p value = 0.886); only diabetes remains independent risk factor of acute kidney injury (odds ratio = 6.26, p value = 0.031)

  11. An intravenously injectable emulsified iodinated oil contrast agent for liver CT. Experimental study of lipiodol emulsion emulsified by lecithin (LEL38) in rabbits

    International Nuclear Information System (INIS)

    Kamei, Tsuyoshi

    1994-01-01

    LEL38 (lipiodol emulsion emulsified by lecithin 38 mgI/ml, mean diameter 200 nm) is a new intravenously injectable oil contrast agent for liver CT. The aim of this report was to evaluate its ability to enhance contrast in the liver of 46 rabbits with regard to the correlation of density with time at an injected dose of 76 mgI/kg (before to 120 minutes after), the correlation of density with dose (0-760 mgI/kg) and the detectability of liver mass. The time-density correlation of LEL38 in the liver, that is, peak density, was achieved after 30 minutes, and it was elevated to 20.9 H. U. Thereafter, it decreased slowly. In the blood vessels, it reached a sharp peak after immediately being elevated to 14. 7 H. U. Thereafter detectability decreased quickly. The maximum difference in density between liver and blood vessels was 34 H. U. after 60 minutes. The dose-density correlation in the liver and blood vessels was linear. Tumors were detected as clear areas of low density. The minimal detectability was about 3 mm. LEL38 may be an effective contrast agent for screening CT studies of liver disease. (author)

  12. Non-immunogenic dextran-coated superparamagnetic iron oxide nanoparticles: a biocompatible, size-tunable contrast agent for magnetic resonance imaging.

    Science.gov (United States)

    Unterweger, Harald; Janko, Christina; Schwarz, Marc; Dézsi, László; Urbanics, Rudolf; Matuszak, Jasmin; Őrfi, Erik; Fülöp, Tamás; Bäuerle, Tobias; Szebeni, János; Journé, Clément; Boccaccini, Aldo R; Alexiou, Christoph; Lyer, Stefan; Cicha, Iwona

    2017-01-01

    Iron oxide-based contrast agents have been in clinical use for magnetic resonance imaging (MRI) of lymph nodes, liver, intestines, and the cardiovascular system. Superparamagnetic iron oxide nanoparticles (SPIONs) have high potential as a contrast agent for MRI, but no intravenous iron oxide-containing agents are currently approved for clinical imaging. The aim of our work was to analyze the hemocompatibility and immuno-safety of a new type of dextran-coated SPIONs (SPIONdex) and to characterize these nanoparticles with ultra-high-field MRI. Key parameters related to nanoparticle hemocompatibility and immuno-safety were investigated in vitro and ex vivo. To address concerns associated with hypersensitivity reactions to injectable nanoparticulate agents, we analyzed complement activation-related pseudoallergy (CARPA) upon intravenous administration of SPIONdex in a pig model. Furthermore, the size-tunability of SPIONdex and the effects of size reduction on their biocompatibility were investigated. In vitro, SPIONdex did not induce hemolysis, complement or platelet activation, plasma coagulation, or leukocyte procoagulant activity, and had no relevant effect on endothelial cell viability or endothelial-monocytic cell interactions. Furthermore, SPIONdex did not induce CARPA even upon intravenous administration of 5 mg Fe/kg in pigs. Upon SPIONdex administration in mice, decreased liver signal intensity was observed after 15 minutes and was still detectable 24 h later. In addition, by changing synthesis parameters, a reduction in particle size contrast agent.

  13. Characteristics of gadolinium-DTPA complex: a potential NMR contrast agent

    International Nuclear Information System (INIS)

    Weinmann, H.J.; Brasch, R.C.; Press, W.R.; Wesbey, G.E.

    1984-01-01

    Chelation of the rare-earth element gadolinium (Gd) with diethylenetriaminepentaacetic acid (DTPA) results in a strongly paramagnetic, stable complex that is well tolerated in animals. The strongly paramagnetic gadolinium complex reduces hydrogen-proton relaxation times even in low concentrations (less than 0.01 mmol/L). The pharmacokinetic behavior of intravenously delivered Gd-DTPA is similar to the well known iodinated contrast agents used in urography and angiography; excretion is predominately through the kidneys with greater than 90% recovery in 24 hr. The intravenous LD 50 of the meglumine salt of Gd-DTPA is 10 mmol/kg for the rat; in vivo there is no evidence of dissociation of the gadolinium ion from the DTPA ligand. The combination of strong proton relaxation, in-vivo stability, rapid urinary excretion, and high tolerance favors the further development and the potential clinical application of gadolinium-DTPA as a contrast enhancer in magnetic resonance imaging

  14. Cranial nerve contrast using nerve-specific fluorophores improved by paired-agent imaging with indocyanine green as a control agent

    Science.gov (United States)

    Torres, Veronica C.; Vuong, Victoria D.; Wilson, Todd; Wewel, Joshua; Byrne, Richard W.; Tichauer, Kenneth M.

    2017-09-01

    Nerve preservation during surgery is critical because damage can result in significant morbidity. This remains a challenge especially for skull base surgeries where cranial nerves (CNs) are involved because visualization and access are particularly poor in that location. We present a paired-agent imaging method to enhance identification of CNs using nerve-specific fluorophores. Two myelin-targeting imaging agents were evaluated, Oxazine 4 and Rhodamine 800, and coadministered with a control agent, indocyanine green, either intravenously or topically in rats. Fluorescence imaging was performed on excised brains ex vivo, and nerve contrast was evaluated via paired-agent ratiometric data analysis. Although contrast was improved among all experimental groups using paired-agent imaging compared to conventional, solely targeted imaging, Oxazine 4 applied directly exhibited the greatest enhancement, with a minimum 3 times improvement in CNs delineation. This work highlights the importance of accounting for nonspecific signal of targeted agents, and demonstrates that paired-agent imaging is one method capable of doing so. Although staining, rinsing, and imaging protocols need to be optimized, these findings serve as a demonstration for the potential use of paired-agent imaging to improve contrast of CNs, and consequently, surgical outcome.

  15. Influence of intravenous contrast agent on dose calculations of intensity modulated radiation therapy plans for head and neck cancer

    International Nuclear Information System (INIS)

    Choi, Youngmin; Kim, Jeung-Kee; Lee, Hyung-Sik; Hur, Won-Joo; Hong, Young-Seoub; Park, Sungkwang; Ahn, Kijung; Cho, Heunglae

    2006-01-01

    Background and purpose: To evaluate the effect of an intravenous contrast agent (CA) on dose calculations and its clinical significance in intensity modulated radiation therapy (IMRT) plans for head and neck cancer. Materials and methods: Fifteen patients with head and neck cancer and involved neck nodes were enrolled. Each patient took two sets of computerized tomography (CT) in the same position before and after intravenous CA injections. Target volumes and organs at risk (OAR) were contoured on the enhanced CT, and then an IMRT plan of nine equiangular beams with a 6 MV X-ray was created. After the fusion of non-enhanced and enhanced CTs, the contours and the IMRT plan created from the enhanced CT were copied and placed to the non-enhanced CT. Doses were calculated again from the non-enhanced CT by the same IMRT plan. The radiation doses calculated from the two sets of CTs were compared with regard to planning target volumes (PTV) and the three OARs, both parotid glands and the spinal cord, by Wilcoxon's signed rank test. Results: The doses (maximum, mean, and the dose of 95% of PTV received (D 95% )) of PTV70 and PTV59.4 calculated from the enhanced CTs were lower than those from the non-enhanced CTs (p < 0.05), but the dose differences were less than 1% compared to the doses calculated from the enhanced CTs. The doses of PTV50.4, parotid glands, and spinal cord were not significantly different between the non-enhanced and enhanced CTs. Conclusions: The difference between the doses calculated from the CTs with and without CA enhancement was tolerably small, therefore using intravenous CA could be recommended for the planning CT of head and neck IMRT

  16. Synchrotron-based intravenous cerebral angiography in a small animal model

    International Nuclear Information System (INIS)

    Kelly, Michael E; Schueltke, Elisabeth; Fiedler, Stephan; Nemoz, Christian; Guzman, Raphael; Corde, Stephanie; Esteve, Francois; LeDuc, Geraldine; Juurlink, Bernhard H J; Meguro, Kotoo

    2007-01-01

    K-edge digital subtraction angiography (KEDSA), a recently developed synchrotron-based technique, utilizes monochromatic radiation and allows acquisition of high-quality angiography images after intravenous administration of contrast agent. We tested KEDSA for its suitability for intravenous cerebral angiography in an animal model. Adult male New Zealand rabbits were subjected to either angiography with conventional x-ray equipment or synchrotron-based intravenous KEDSA, using an iodine-based contrast agent. Angiography with conventional x-ray equipment after intra-arterial administration of contrast agent demonstrated the major intracranial vessels but no smaller branches. KEDSA was able to visualize the major intracranial vessels as well as smaller branches in both radiography mode (planar images) and tomography mode. Visualization was achieved with as little as 0.5 ml kg -1 of iodinated contrast material. We were able to obtain excellent visualization of the cerebral vasculature in an animal model using intravenous injection of contrast material, using synchrotron-based KEDSA

  17. Studies on polyaspartamide gadolinium complexes as potential magnetic resonance imaging contrast agents

    International Nuclear Information System (INIS)

    Yan Guoping; Liu Maili; Li Liyun

    2005-01-01

    Purpose: A series of polyaspartamide gadolinium complexes containing pyridoxamine groups were studied as the potential magnetic resonance imaging (MRI) contrast agents for liver enhancement. Methods: These polyaspartamide gadolinium complexes were prepared and evaluated by relaxivity, acute toxicity studies and magnetic resonance imaging of the liver in rats. Results: These polyaspartamide gadolinium complexes have higher relaxation effectiveness than that of the clinically used gadolinium diethylenetriaminepentaacetic acid and possess the low intravenous acute toxicities to Institute for Cancer Research (ICR) mice. Magnetic resonance imaging of the liver in rats indicated that they greatly enhance the contrast of magnetic resonance images and provide prolonged intravascular duration in the liver. Conclusion: These results indicated that the polyaspartamide gadolinium complexes containing pyridoxamine groups could be considered as the appropriate MRI contrast agents for liver enhancement

  18. Utility decay rates of T1-weighted magnetic resonance imaging contrast based on redox-sensitive paramagnetic nitroxyl contrast agents

    International Nuclear Information System (INIS)

    Matsumoto, Ken-ichiro

    2009-01-01

    The availability and applicability of the combination of paramagnetic nitroxyl contrast agent and T 1 -weighted gradient echo (GE)-based dynamic magnetic resonance imaging (MRI) measurement for redox imaging are described. The time courses of T 1 -weighted GE MRI signal intensities according to first-order paramagnetic loss of a nitroxyl contrast agent were simulated for several experimental conditions. The apparent decay rate calculated based on decreasing T 1 -weighted MRI contrast (k MRI ) can show an approximate value of the original decay rate (k true ) discretionarily given for simulation with suitable experimental parameters. The difference between k MRI and k true can be sufficiently small under T 1 -weighted spoiled gradient echo (SPGR) scan conditions (repetition time=75 ms, echo time=3 ms, and flip angle=45deg), with a conventional redox-sensitive nitroxyl contrast agent, such as 4-hydroxy-2,2,6,6,-tetramethylpiperidine-N-oxyl (TEMPOL) and/or 3-carbamoyl-2,2,5,5-tetramethylpyrrolidine-N-oxyl (carbamoyl-PROXYL), and with intravenous (i.v.) doses of below 1.5 γmol/g body weight (b.w.) for mice. The results of this simulation suggest that the k MRI of nitroxyl contrast agents can be the primary index of redox status under biological conditions. (author)

  19. Biocompatible Polyhydroxyethylaspartamide-based Micelles with Gadolinium for MRI Contrast Agents

    Directory of Open Access Journals (Sweden)

    Kim Hyo Jeong

    2010-01-01

    Full Text Available Abstract Biocompatible poly-[N-(2-hydroxyethyl-d,l-aspartamide]-methoxypoly(ethyleneglycol-hexadecylamine (PHEA-mPEG-C16 conjugated with 1,4,7,10-tetraazacyclododecan-1,4,7,10-tetraacetic acid-gadolinium (DOTA-Gd via ethylenediamine (ED was synthesized as a magnetic resonance imaging (MRI contrast agent. Amphiphilic PHEA-mPEG-C16-ED-DOTA-Gd forms micelle in aqueous solution. All the synthesized materials were characterized by proton nuclear magnetic resonance (1H NMR. Micelle size and shape were examined by dynamic light scattering (DLS and atomic force microscopy (AFM. Micelles with PHEA-mPEG-C16-ED-DOTA-Gd showed higher relaxivities than the commercially available gadolinium contrast agent. Moreover, the signal intensity of a rabbit liver was effectively increased after intravenous injection of PHEA-mPEG-C16-ED-DOTA-Gd.

  20. Polymer Assembly Encapsulation of Lanthanide Nanoparticles as Contrast Agents for In Vivo Micro-CT.

    Science.gov (United States)

    Cruje, Charmainne; Dunmore-Buyze, Joy; MacDonald, Jarret P; Holdsworth, David W; Drangova, Maria; Gillies, Elizabeth R

    2018-03-12

    Despite recent technological advancements in microcomputed tomography (micro-CT) and contrast agent development, preclinical contrast agents are still predominantly iodine-based. Higher contrast can be achieved when using elements with higher atomic numbers, such as lanthanides; lanthanides also have X-ray attenuation properties that are ideal for spectral CT. However, the formulation of lanthanide-based contrast agents at the high concentrations required for vascular imaging presents a significant challenge. In this work, we developed an erbium-based contrast agent that meets micro-CT imaging requirements, which include colloidal stability upon redispersion at high concentrations, evasion of rapid renal clearance, and circulation times of tens of minutes in small animals. Through systematic studies with poly(ethylene glycol) (PEG)-poly(propylene glycol), PEG-polycaprolactone, and PEG-poly(l-lactide) (PLA) block copolymers, the amphiphilic block copolymer PEG 114 -PLA 53 was identified to be ideal for encapsulating oleate-coated lanthanide-based nanoparticles for in vivo intravenous administration. We were able to synthesize a contrast agent containing 100 mg/mL of erbium that could be redispersed into colloidally stable particles in saline after lyophilization. Contrast enhancement of over 250 HU was achieved in the blood pool for up to an hour, thereby meeting the requirements of live animal micro-CT.

  1. Cellular internalization and morphological analysis after intravenous injection of a highly hydrophilic octahedral rhenium cluster complex - a new promising X-ray contrast agent.

    Science.gov (United States)

    Krasilnikova, Anna A; Solovieva, Anastasiya O; Trifonova, Kristina E; Brylev, Konstantin A; Ivanov, Anton A; Kim, Sung-Jin; Shestopalov, Michael A; Fufaeva, Maria S; Shestopalov, Alexander M; Mironov, Yuri V; Poveshchenko, Alexander F; Shestopalova, Lidia V

    2016-11-01

    The octahedral cluster compound Na 2 H 8 [{Re 6 Se 8 }(P(C 2 H 4 CONH 2 )(C 2 H 4 COO) 2 ) 6 ] has been shown to be highly radio dense, thus becoming a promising X-ray contrast agent. It was also shown that this compound had low cytotoxic effect in vitro, low acute toxicity in vivo and was eliminated rapidly from the body through the urinary tract. The present contribution describes a more detailed cellular internalization assay and morphological analysis after intravenous injection of this hexarhenium cluster compound at different doses. The median lethal dose (LD 50 ) of intravenously administrated compound was calculated (4.67 ± 0.69 g/kg). Results of the study clearly indicated that the cluster complex H n [{Re 6 Se 8 }(P(C 2 H 4 CONH 2 )(C 2 H 4 COO) 2 ) 6 ] n-10 was not internalized into cells in vitro and induced only moderate morphological alterations of kidneys at high doses without any changes in morphology of liver, spleen, duodenum, or heart of mice. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Intravenous digital subtraction angiography contrast media time-concentration curves

    International Nuclear Information System (INIS)

    Burbank, F.H.; Brody, W.R.

    1985-01-01

    At any specified radiation dose and system signal-to-noise ratio, temporal (masked-mode) intravenous digital subtraction angiography (IV-DSA) image quality is dependent upon the shape of the arterial time-concentration curve produced by the intravenous injection of iodinated contrast media. If contrast media appears in the arterial circulation as a compact bolus and reaches a high peak, images containing low or no iodine (the mask image or images) and high iodine concentration (the enhanced image or images) can be obtained close together in time, maximizing contrast media enhancement and minimizing the potential for spatial movement (misregistration). However, if the contrast media bolus is broad, rising slowly to a low concentration peak, sufficient time may pass for movement to occur and the opacification difference between the mask image and the enhanced image may be too small to visualize vessels of interest. Consequently, knowledge of the rules which govern the formation of time-concentration curves is central to IV-DSA

  3. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children

    Energy Technology Data Exchange (ETDEWEB)

    Ayyala, Rama S.; Lee, Edward Y. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Zurakowski, David [Boston Children' s Hospital and Harvard Medical School, Departments of Anesthesiology and Surgery, Boston, MA (United States)

    2015-11-15

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  4. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children

    International Nuclear Information System (INIS)

    Ayyala, Rama S.; Lee, Edward Y.; Zurakowski, David

    2015-01-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  5. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children.

    Science.gov (United States)

    Ayyala, Rama S; Zurakowski, David; Lee, Edward Y

    2015-11-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  6. The Royal Australian College of Radiologists (RACR) survey of reactions to intravenous ionic and non-ionic contrast media

    International Nuclear Information System (INIS)

    Palmer, J.F.

    1989-01-01

    The Royal Australian College of Radiologists (RACR) expressed concern as to medico-legal implications of the continued use of conventional ionic contrast media in view of the availability of the new low-osmolar media. The new agents had demonstrated significant advantages and it was anticipated that their use would be associated with a lower incidence of undesirable reactions and deaths. However, these new media are significantly more expensive than conventional ionic media and complete changes to these agents has considerable implications for health budgets. Since it was the view of the RACR that there was insufficient information available of the incidence of reactions in clinical use to justify a complete change, a prospective survey of reations to intravenous contrast media injections was initiated. Particpants were issued a simple form, which required for each patient a record of the presence or absence of risk factors, wether ionic or non-ionic contrast media were used, and of the severity of eventual reactions. The results of about 170.000 patients were reported. The survey demonstrated the relative safety of non-ionic media for intravenous use. Despite the relative high cost of these media the continued use of conventional ionic media will become increasingly difficult to justify. (H.W.). 9 refs.; 4 tabs

  7. Comparison of the image quality of intravenous urograms using low-osmolar contrast media

    International Nuclear Information System (INIS)

    Kaye, B.; Howard, J.; Foord, K.D.; Cumberland, D.C.

    1988-01-01

    Almost equivalent, intravenous iodine doses of the three new low-osmolar contrast media, ioxaglate (Hexabrix), iopamidol (Niopam) and iohexol (Omnipaque) have been compared for image quality on the intravenous urogram. Generally good radiographic images were obtained. Iohexol gave better results for the nephrogram and pelvicalyceal distension compared with the other contrast media, but only the nephrogram results were statistically significant. Pyelographic density and ureteric distension and density were similar with all three contrast media. In patients where low-osmolality contrast media need to be used for intravenous urography, we suggest that iohexol gives the best radiographic images. Other factors, such as cost and the relative incidence of side-effects of the low-osmolar contrast media also need to be taken into consideration. (author)

  8. Feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in lung cancer treatment planning

    International Nuclear Information System (INIS)

    Xiao Jianghong; Zhang Hong; Gong Youling; Fu Yuchuan; Tang Bin; Wang Shichao; Jiang Qingfeng; Li Ping

    2010-01-01

    Background and purpose: To investigate the feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in 3-dimensional conformal radiotherapy (3D-CRT), stereotactic body radiation therapy (SBRT) and intensity-modulated radiotherapy (IMRT) treatment planning for lung cancers, respectively. Materials and methods: Twelve patients with bulky lung tumors and 14 patients with small lung tumors were retrospectively analyzed. Each patient took two sets of CT in the same position with active breathing control (ABC) technique before and after intravenous contrast agent (CA) injections. Bulky tumors were planned with 3D-CRT, while SBRT plans were generated for patients with small tumors based on CT scans with intravenous CA. In addition, IMRT plans were generated for patients with bulky tumors to continue on a planning study. All plans were copied and replaced on the scans without intravenous CA. The radiation doses calculated from the two sets of CTs were compared with regard to planning volumes (PTV), the organ at-risk (OAR) and the lungs using Wilcoxon's signed rank test. Results: In comparisons for 3D-CRT plans, CT scans with intravenous CA reduced the mean dose and the maximum dose of PTV with significant differences (p 95 ) for targets, respectively (p < 0.05). There was no statistical significance for lung parameters between two sets of scans in SBRT plans and IMRT plans. Conclusions: The enhanced CT scans can be used for both target delineation and treatment planning in 3D-CRT. The dose difference caused by intravenous CA is small. But for SBRT and IMRT, the minimum irradiation dose in targets may be estimated to be increased up to 2.71% while the maximum dose may be estimated to be decreased up to 1.36%. However, the difference in dose distribution in most cases were found to be clinical tolerable.

  9. Contrast-enhanced voiding urosonography: in vitro evaluation of a second-generation ultrasound contrast agent for in vivo optimization.

    Science.gov (United States)

    Back, Susan J; Edgar, J Christopher; Canning, Douglas A; Darge, Kassa

    2015-09-01

    Pediatric contrast-enhanced ultrasound (CEUS) is primarily performed outside the United States where a track record for safety in intravenous and intravesical applications has been established. Contrast-enhanced voiding urosonography (ceVUS) has also been shown to have a much higher rate of vesicoureteral reflux detection compared to voiding cystourethrography. US contrast agents available in the United States differ from those abroad. Optison® (GE Healthcare, Princeton, NJ) is such an US contrast agent. While Optison® has similar characteristics to other second-generation agents, it has never been used for ceVUS. In vitro optimization of dose and imaging parameters as well as assessment of contrast visualization when delivered in conditions similar to ceVUS are necessary starting points prior to in vivo applications. To optimize the intravesical use of Optison® in vitro for ceVUS before its use in pediatric studies. The experimental design simulated intravesical use. Using 9- and 12-MHz linear transducers, we scanned 20-mL syringes varying mechanical index, US contrast agent concentration (0.25%, 0.5%, 1.0%), solvent (saline, urine, radiographic contrast agent) and time out of refrigeration. We evaluated mechanical index settings and contrast duration, optimized the contrast dose, measured the effect of urine and radiographic contrast agent, and the impact of length of time of contrast outside of the refrigerator on US contrast appearance. We scanned 50-ml saline bags to assess the appearance and duration of US contrast with different delivery systems (injection vs. infusion). Consistent contrast visualization was achieved at a mechanical index of 0.06-0.17 and 0.11-0.48 for the L9 and L12 MHz transducers (P contrast visualization of the microbubbles with a higher transducer frequency. The lowest mechanical index for earliest visible microbubble destruction was 0.21 for the 9 MHz and 0.39 for the 12 MHz (P contrast agent volume to bladder filling was the

  10. Diagnostic utility of intravenous contrast for MR imaging in pediatric appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Lyons, Gray R.; Renjen, Pooja; Kovanlikaya, Arzu [New York-Presbyterian Hospital/Weill Cornell Medicine, Department of Radiology, New York, NY (United States); Askin, Gulce; Giambrone, Ashley E. [New York-Presbyterian Hospital/Weill Cornell Medicine, Department of Biostatistics and Epidemiology, New York, NY (United States); Beneck, Debra [New York-Presbyterian Hospital/Weill Cornell Medicine, Department of Pathology, New York, NY (United States)

    2017-04-15

    Magnetic resonance imaging (MRI) is increasingly employed as a diagnostic modality for suspected appendicitis in children. However, there is uncertainty as to which MRI sequences are sufficient for safe, timely and accurate diagnosis. Several recent studies have described different MRI protocols, including exams both with and without the use of intravenous contrast. We hypothesized that intravenous contrast may be useful in some patients but could be safely omitted in others. All MRI examinations (n=112) performed at our institution for evaluating appendicitis in children were retrospectively reevaluated. Exams were reread by pediatric radiologists under three conditions: With postcontrast images, Without postcontrast images, and Without/With - selective use of postcontrast sequences only when needed for diagnostic certainty. Samples were scored as positive, negative or equivocal for appendicitis. Findings were compared to pathological or clinical follow-up in the medical record. Without the use of intravenous contrast yielded more equivocal results (12.4%) compared to With contrast (3.4%). By selectively using postcontrast sequences, the Without/With group yielded fewer equivocal results (1.1%) compared to Without while also reducing contrast use 79.8% compared to the With contrast group. No significant differences in conditional sensitivity or conditional specificity were detected among the three groups. MRI diagnosis of acute appendicitis can be performed without contrast for most patients; injection of contrast can be reserved for only those patients with equivocal non-contrast imaging. (orig.)

  11. Contrast agents for MRI

    International Nuclear Information System (INIS)

    Bonnemain, B.

    1994-01-01

    Contrast agents MRI (Magnetic Resonance Imaging) have been developed to improve the diagnostic information obtained by this technic. They mainly interact on T1 and T2 parameters and increase consequently normal to abnormal tissues contrast. The paramagnetic agents which mainly act on longitudinal relaxation rate (T1) are gadolinium complexes for which stability is the main parameter to avoid any release of free gadolinium. The superparamagnetic agents that decrease signal intensity by an effect on transversal relaxation rate (T2) are developed for liver, digestive and lymph node imaging. Many area of research are now opened for optimal use of present and future contrast agents in MRI. (author). 28 refs., 4 tabs

  12. Magnetic susceptibility imaging with a nonionic contrast agent

    International Nuclear Information System (INIS)

    Cacheris, W.; Rocklage, S.M.; Quay, S.; Dow, W.; Love, D.; Worah, D.; Lim, K.

    1988-01-01

    The magnetic susceptibility mechanism for MR imaging contrast enhancement has the advantage of providing useful information, such as cerebral blood flow, without crossing the blood-brain barrier. In this paper the authors report the use of a highly effective, relatively nontoxic chelate as a magnetic susceptibility agent. Dy-DTPA-bis(methylamide) (Dy-DTPA-BMA) has an extremely low acute toxicity (LD-50, intravenous, mice ∼ 40 mmol/kg). Doses of 1 mmol/kg and 2 mmol/kg Dy-DTPA-BMA lowered the initial signal intensity 63% to 57%, respectively. The utility of this technique in detecting areas of reduced blood flow within the brain was demonstrated by imaging a rabbit with a cerebral perfusion deficit

  13. Training requirements for the administration of intravenous contrast ...

    African Journals Online (AJOL)

    Background. The administration of intravenous contrast media (IVCM) is one of the key areas currently under investigation for inclusion in the South African (SA) radiographers' scope of practice. However, for the radiographers to legally administer IVCM, training guidelines must first be identified, developed and accredited ...

  14. In vitro and in vivo evaluation of poly(L-lactide-co glycolide)( PLGA) micro bubbles as a contrast agent

    International Nuclear Information System (INIS)

    Cui, W.; Bei, J.; Wang, S.; Zhao, Y.; Zhi, G.

    2005-01-01

    To achieve reliable and reproducible myocardial opacification after intravenous administration of echocardiographic contrast agents, this study was performed to fabricate a kind of poly(L-lactide-co-glycolide) (PLGA) micro bubbles-based contrast agent with a modified double emulsion method which incorporates and later sublimes po rogen, leaving voids capable of being filled with gas in their places. The morphology and size distribution of the micro bubbles were investigated. The porous inner structure formed in the micro bubble contrast agents were further proved by con focal laser scanning microscope (CLSM). All the results satisfied the requirements of ideal contrast agents. Acoustic measurement set-up detected the excellent scatter ability of the PLGA (70/30) micro bubbles. It demonstrated this kind of polymer-shell contrast agents could achieve efficient left ventricular opacification and the improved delineation of left ventricular endocardial borders. Especially the safe and successful myocardial opacification in close-chest dogs were observed

  15. Transient angioedema of small bowel secondary to intravenous iodinated contrast medium

    Directory of Open Access Journals (Sweden)

    Kirankumar N Kulkarni

    2014-01-01

    Full Text Available We report the clinical details and imaging findings of a case of transient angioedema of the small bowel following intravenous administration of non-ionic iodinated contrast material in a 17 year old female with no predisposing risk factors. Findings included long segment, symmetric, circumferential, low-density, bowel wall thickening involving the duodenum, jejunum, and most of the ileum on computed tomography scan obtained at 7 min following intravenous contrast material injection. This entity is self-limiting with a favourable clinical outcome and requires no specific treatment but only aggressive clinical monitoring.

  16. Are intravenous injections of contrast media really less nephrotoxic than intra-arterial injections?

    Energy Technology Data Exchange (ETDEWEB)

    Nyman, Ulf [University of Lund, Department of Diagnostic Radiology, Trelleborg (Sweden); Almen, Torsten [Skaane University Hospital, Department of Clinical Sciences/Medical Radiology, University of Lund, Malmoe (Sweden); Jacobsson, Bo [University of Gothenburg and the Sahlgrenska Academy, Department of Diagnostic Radiology, The Queen Silvia Children' s Hospital, Goeteborg (Sweden); Aspelin, Peter [Karolinska Institute and University Hospital, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Stockholm (Sweden)

    2012-06-15

    We oppose the opinion that the intra-arterial administration of iodine-based contrast media (CM) appears to pose a greater risk of contrast medium-induced nephropathy (CIN) than intravenous administration since (1) in intra-arterial coronary procedures and most other intra-arterial angiographic examinations, CM injections are also intravenous relative to the kidneys, (2) there is a lack of comparative trials studying the risk of CIN between intra-arterial and intravenous procedures with matched risk factors and CM doses, (3) a bias selection of patients with fewer risk factors may explain the seemingly lower rate of CIN after CT in comparison with coronary interventions, (4) the rate of CIN following intra-arterial coronary procedures may also be exaggerated owing to other causes of acute kidney failure, such as haemodynamic instability and microembolisation, (5) roughly the same gram-iodine/GFR ratio ({approx}1:1) as a limit of relatively safe CM doses has preliminarily been found for both intravenous CT and intra-arterial coronary procedures and (6) the substantially higher injected intravenous CM dose rate during CT relative to an intra-arterial coronary procedure might actually pose a higher risk of CIN following CT. Key Points circle Most intra-arterial injections of contrast media are intravenous relative to the kidneys. circle No evidence that intravenous CM injections should be less nephrotoxic than intra-arterial. circle Considerably higher dose rates of CM are used for CT relative to intra-arterial procedures. circle Higher dose rates may pose higher nephrotoxic risk for intravenous based CT studies. (orig.)

  17. Intravenous contrast enhanced computed tomography colonoscopy in children with suspected colonic polyps

    International Nuclear Information System (INIS)

    Bhatia, Anmol; Saxena, Akshay K.; Kalra, Naveen; Sodhi, Kushaljit S.; Thapa, Babu R.; Rao, Katragadda L.N.; Khandelwal, Niranjan

    2013-01-01

    Objective: The purpose of this study was to evaluate the diagnostic performance of intravenous contrast enhanced computed tomographic colonoscopy (IVCTC) in the diagnosis of clinically suspected colorectal polyps in children, using conventional colonoscopy (CC) as the gold standard. Methods: This was a prospective study conducted between July 2008 and June 2010. 30 pediatric patients with history of rectal bleeding and clinically suspected to have colorectal polyps were enrolled. All of the patients underwent IVCTC followed by CC. 30 IVCTC and 31 CC were performed in 30 patients. The findings of IVCTC were compared with those of CC. Statistical analysis was performed to obtain diagnostic performance values of IVCTC on per polyp (sensitivity and positive predictive value) and per patient (sensitivity, specificity, positive predictive value and negative predictive value) basis. Results: By IVCTC, 63 polyps were detected in 28 patients of which 53 polyps were eligible for inclusion in the statistical analysis. 60 polyps were detected by CC in 28 patients of which 50 polyps were eligible for inclusion in the statistical analysis. The per polyp sensitivity and positive predictive values were 94% and 88.6% respectively. The per patient sensitivity, specificity, positive predictive value, and negative predictive values were 96.4, 50, 96.4, and 50% respectively. Twenty polyps, in 10 patients, were visualized only after intravenous contrast administration of which 5 polyps, in 5 patients, were likely to have been missed in the absence of the intravenous contrast injection as these polyps were submerged in fluid. Four patients would have had a false negative CTC examination if the intravenous contrast had not been injected; while in another patient, the number of polyps would have been underestimated. Conclusion: CTC is capable of serving as a safe and efficient non-invasive tool for evaluating children with clinically suspected colorectal polyps. Administration of

  18. Whole tissue AC susceptibility after superparamagnetic iron oxide contrast agent administration in a rat model

    International Nuclear Information System (INIS)

    Lazaro, Francisco Jose; Gutierrez, Lucia; Rosa Abadia, Ana; Soledad Romero, Maria; Lopez, Antonio; Jesus Munoz, Maria

    2007-01-01

    A magnetic AC susceptibility characterisation of rat tissues after intravenous administration of superparamagnetic iron oxide (Endorem ( R)), at the same dose as established for Magnetic Resonance Imaging (MRI) contrast enhancement in humans, has been carried out. The measurements reveal the presence of the contrast agent as well as that of physiological ferritin in liver and spleen while no traces have been magnetically detected in heart and kidney. This preliminary work opens suggestive possibilities for future biodistribution studies of any type of magnetic carriers

  19. A tomographic approach to intravenous coronary arteriography

    International Nuclear Information System (INIS)

    Ritman, E.L.; Bove, A.A.

    1986-01-01

    Coronary artery anatomy can be visualized using high speed, volume scanning X-ray CT. A single scan during a bolus injection of contrast medium provides image data for display of all angles of view of the opacified coronary arterial tree. Due to the tomographic nature of volume image data the superposition of contrast filled cardiac chambers, such as would occur in the levophase of an intravenous injection of contrast agent, can be eliminated. Data are presented which support these statements. The Dynamic Spatial Reconstructor (DSR) was used to scan a life-like radiologic phantom of an adult human thorax in which the left atrial and ventricular chambers and the major epicardial coronary arteries were opacified so as to simulate the levophase of an intravenous injection of contrast agent. A catheter filled with diluted contrast agent and with regions of luminal narrowing (i.e. 'stenoses') was advanced along a tract equivalent to a right ventricular catheterization. Ease of visualization of the catheter 'stenoses' and the accuracy with which they can be measured are presented. (Auth.)

  20. Intravenous contrast injection significantly affects bone mineral density measured on CT

    NARCIS (Netherlands)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J. J.; Mohamed Hoesein, Firdaus A A; de Jong, Pim A.

    OBJECTIVE: The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. METHODS: One hundred and fifty-two patients (99 without and

  1. The fabrication of novel nanobubble ultrasound contrast agent for potential tumor imaging

    Energy Technology Data Exchange (ETDEWEB)

    Xing Zhanwen; Ke Hengte; Yue Xiuli; Dai Zhifei [Nanobiotechnology Division, State Key Laboratory of Urban Water Resources and Environment, School of Sciences, Harbin Institute of Technology, Harbin 150080 (China); Wang Jinrui; Zhao Bo [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China); Liu Jibin, E-mail: zhifei.dai@hit.edu.cn, E-mail: ji-bin.liu@jefferson.edu [Ultrasound Research and Education Institute, Thomas Jefferson University, Philadelphia, PA 19107 (United States)

    2010-04-09

    Novel biocompatible nanobubbles were fabricated by ultrasonication of a mixture of Span 60 and polyoxyethylene 40 stearate (PEG40S) followed by differential centrifugation to isolate the relevant subpopulation from the parent suspensions. Particle sizing analysis and optical microscopy inspection indicated that the freshly generated micro/nanobubble suspension was polydisperse and the size distribution was bimodal with large amounts of nanobubbles. To develop a nano-sized contrast agent that is small enough to leak through tumor pores, a fractionation to extract smaller bubbles by variation in the time of centrifugation at 20g (relative centrifuge field, RCF) was suggested. The results showed that the population of nanobubbles with a precisely controlled mean diameter could be sorted from the initial polydisperse suspensions to meet the specified requirements. The isolated bubbles were stable over two weeks under the protection of perfluoropropane gas. The acoustic behavior of the nano-sized contrast agent was evaluated using power Doppler imaging in a normal rabbit model. An excellent power Doppler enhancement was found in vivo renal imaging after intravenous injection of the obtained nanobubbles. Given the broad spectrum of potential clinical applications, the nano-sized contrast agent may provide a versatile adjunct for ultrasonic imaging enhancement and/or treatment of tumors.

  2. The fabrication of novel nanobubble ultrasound contrast agent for potential tumor imaging

    International Nuclear Information System (INIS)

    Xing Zhanwen; Ke Hengte; Yue Xiuli; Dai Zhifei; Wang Jinrui; Zhao Bo; Liu Jibin

    2010-01-01

    Novel biocompatible nanobubbles were fabricated by ultrasonication of a mixture of Span 60 and polyoxyethylene 40 stearate (PEG40S) followed by differential centrifugation to isolate the relevant subpopulation from the parent suspensions. Particle sizing analysis and optical microscopy inspection indicated that the freshly generated micro/nanobubble suspension was polydisperse and the size distribution was bimodal with large amounts of nanobubbles. To develop a nano-sized contrast agent that is small enough to leak through tumor pores, a fractionation to extract smaller bubbles by variation in the time of centrifugation at 20g (relative centrifuge field, RCF) was suggested. The results showed that the population of nanobubbles with a precisely controlled mean diameter could be sorted from the initial polydisperse suspensions to meet the specified requirements. The isolated bubbles were stable over two weeks under the protection of perfluoropropane gas. The acoustic behavior of the nano-sized contrast agent was evaluated using power Doppler imaging in a normal rabbit model. An excellent power Doppler enhancement was found in vivo renal imaging after intravenous injection of the obtained nanobubbles. Given the broad spectrum of potential clinical applications, the nano-sized contrast agent may provide a versatile adjunct for ultrasonic imaging enhancement and/or treatment of tumors.

  3. The fabrication of novel nanobubble ultrasound contrast agent for potential tumor imaging

    Science.gov (United States)

    Xing, Zhanwen; Wang, Jinrui; Ke, Hengte; Zhao, Bo; Yue, Xiuli; Dai, Zhifei; Liu, Jibin

    2010-04-01

    Novel biocompatible nanobubbles were fabricated by ultrasonication of a mixture of Span 60 and polyoxyethylene 40 stearate (PEG40S) followed by differential centrifugation to isolate the relevant subpopulation from the parent suspensions. Particle sizing analysis and optical microscopy inspection indicated that the freshly generated micro/nanobubble suspension was polydisperse and the size distribution was bimodal with large amounts of nanobubbles. To develop a nano-sized contrast agent that is small enough to leak through tumor pores, a fractionation to extract smaller bubbles by variation in the time of centrifugation at 20g (relative centrifuge field, RCF) was suggested. The results showed that the population of nanobubbles with a precisely controlled mean diameter could be sorted from the initial polydisperse suspensions to meet the specified requirements. The isolated bubbles were stable over two weeks under the protection of perfluoropropane gas. The acoustic behavior of the nano-sized contrast agent was evaluated using power Doppler imaging in a normal rabbit model. An excellent power Doppler enhancement was found in vivo renal imaging after intravenous injection of the obtained nanobubbles. Given the broad spectrum of potential clinical applications, the nano-sized contrast agent may provide a versatile adjunct for ultrasonic imaging enhancement and/or treatment of tumors.

  4. Correlation between image quality of CT scan and amount of intravenous contrast media

    International Nuclear Information System (INIS)

    Yoon, Dae Young; Choi, Dae Seob; Kim, Seung Hyup; Han, Joon Koo; Choi, Byung Ihn; Im, Jung Gi; Han, Moon Hee; Chang, Kee Hyun; Kim, Jong Hyo; Han, Man Chung

    1993-01-01

    A blind, comparative clinical study was performed prospectively to examine the correlation between image quality of CT scan in terms of contrast enhancement effect and amount of intravenous contrast media. A total of 357 patients were randomized into two groups. Ionic high-osmolality contrast media (68% meglumine ioglicate) was administered intravenously as 100 ml bolus in one group and as 50 ml bolus in the other group. Statistically significant differences of image quality were found in CT scans of the brain, head and neck, chest and abdomen (p 0.05). We suggest that amount of contrast media may be reduced in pelvis CT without significant degradation of image quality

  5. PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients

    International Nuclear Information System (INIS)

    Berthelsen, A.K.; Holm, S.; Loft, A.; Klausen, T.L.; Andersen, F.; Hoejgaard, L.

    2005-01-01

    If the CT scan of a combined PET/CT study is performed as a full diagnostic quality CT scan including intravenous (IV) contrast agent, the quality of the joint PET/CT procedure is improved and a separate diagnostic CT scan can be avoided. CT with IV contrast can be used for PET attenuation correction, but this may result in a bias in the attenuation factors. The clinical significance of this bias has not been established. Our aim was to perform a prospective clinical study where each patient had CT performed with and without IV contrast agent to establish whether PET/CT with IV contrast can be used for PET attenuation without reducing the clinical value of the PET scan. A uniform phantom study was used to document that the PET acquisition itself is not significantly influenced by the presence of IV contrast medium. Then, 19 patients referred to PET/CT with IV contrast underwent CT scans without, and then with contrast agent, followed by an 18 F-fluorodeoxyglucose whole-body PET scan. The CT examinations were performed with identical parameters on a GE Discovery LS scanner. The PET data were reconstructed with attenuation correction based on the two CT data sets. A global comparison of standard uptake value (SUV) was performed, and SUVs in tumour, in non-tumour tissue and in the subclavian vein were calculated. Clinical evaluation of the number and location of lesions on all PET/CT scans was performed twice, blinded and in a different random order, by two independent nuclear medicine specialists. In all patients, the measured global SUV of PET images based on CT with IV contrast agent was higher than the global activity using non-contrast correction. The overall increase in the mean SUV (for two different conversion tables tested) was 4.5±2.3% and 1.6±0.5%, respectively. In 11/19 patients, focal uptake was identified corresponding to malignant tumours. Eight out of 11 tumours showed an increased SUV max (2.9±3.1%) on the PET images reconstructed using IV contrast

  6. Is the routine use of intravenous contrast justified in the workup of ...

    African Journals Online (AJOL)

    The indications for the administration of intravenous contrast media to adult patients presenting with firsttime seizures and a normal pre-contrast study are not clear. A retrospective audit of such patients was done and compared with the post-contrast study. In our study sample of 205 patients all the post-contrast scans were ...

  7. Contrast agents for tumor diagnosis in magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Goto, Rensuke; Doi, Hisayoshi; Okada, Shoji [University of Shizuoka (Japan). School of Pharmaceutical Science; Yano, Masayuki; Katano, Susumu; Nakajima, Nobuaki

    1992-01-01

    In order to develop contrast agents for tumor diagnosis in magnetic resonance imaging (MRI), we investigated the effects of several gadolinium complexes on T{sub 1} relaxation time of proton in some tissues of Ehrlich solid tumor-bearing mice. L-Aspartic acid, L-glutamic acid, DL-homocysteine, L-glutamyl-glutamic acid, glutathione, sperimidine and ethylenediaminetetrakis (methylenephosphate) (EDTMP) were used as ligands for Gd{sup 3+}. Since each Gd-complex could not be purified except Gd-EDTMP, the mixture of GdCl{sub 3} and a ligand was administered intravenously. Among the compounds tested, the mixture of aspartic acid, glutathione or spermidine with GdCl{sub 3} showed almost the same or above reduction of T{sub 1} relaxation times in the tumor tissue compared with Gd-diethylenetriamine pentaacetic acid (Gd-DTPA) which is used clinically. Furthermore, the contrast-enhancing effect of the three mixtures in the tumor was observed by in vivo T{sub 1}-weighted magnetic resonance imaging. The in vivo tissue distribution using radioactive {sup 153}Gd{sup 3+} showed that these mixtures mentioned above were also taken up more highly in the tumor than {sup 153}GdCl{sub 3} itself and {sup 153}Gd-DTPA, suggesting the formation of Gd-complexes. However, the overall tissue distribution of the mixtures was similar to that of {sup 153}GdCl{sub 3} because the Gd-complexes were not purified. Gd-EDTMP exhibited the almost same effects with Gd-DTPA as a contrast agent. (author).

  8. Contrast Agent in Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Vu-Quang, Hieu

    2015-01-01

    Nanoparticles have been employed as contrast agent in magnetic resonance imaging (MRI) in order to improve sensitivity and accuracy in diagnosis. In addition, these contrast agents are potentially combined with other therapeutic compounds or near infrared bio-imaging (NIR) fluorophores to obtain...... theranostic or dual imaging purposes, respectively. There were two main types of MRI contrast agent that were synthesized during this PhD project including fluorine containing nanoparticles and magnetic nanoparticles. In regard of fluorine containing nanoparticles, there were two types contrast agent...... cancer cells for cancer diagnosis in MRI. F127-Folate coated SPION were stable in various types of suspension medium for over six months. They could specifically target folate receptor of cancer cells in vitro and in vivo thus enhancing the contrast in MRI T2/T2* weighted images. These are preliminary...

  9. Evaluation of clot formation in blood-contrast agent mixture: experimental study on ionic/nonionic contrast agents and plastic/ glass syringes

    International Nuclear Information System (INIS)

    Shim, Hyung Jin; Lee, Jong Beum; Lee, Yong Chul; Lee, Kwan Seh; Kim, Kun Sang

    1991-01-01

    Recent introduction of low-osmolar nonionic contrast agents has allowed the performance of angiography with certain advantages such as reduced pain, reduced osmotic load and other potential advantages, over high osmolar ionic contrast agents. But the potential thrombogenic risk of nonionic contrast agent has been debate because of their weak anticoagulation effect. Several reports have recently documented the formation of thrombi in catheters and syringes containing nonionic contrast agent, and thromboembolic episodes have been noted during angiographic procedures. We have also been experienced blood clotting within blood mixed contrast agent syringe during angiography. Thus, we have studied with blood mixed ionic (Diatrizoate, Ioglicate) agents and nonionic (Iopamidol, Iopromide) agents, that used usually in our hospital, and saline in plastic and glass syringes. Each syringes were checked the clot formation on 10,30,60,90 minutes. Total 340 samples were obtained from 8 adults before angiography. Our data showed that nonionic contrast agents had significantly lesser anticoagulation effect than ionic contrast agents (ρ < 0.0001) on Chi-square test), both in plastic and glass syringes. And formation of clotting in glass syringes were significantly greater than that in plastic syringes (ρ < 0.0001). Thus meticulous technique is required to prevent thrombosis during angiographic procedure using nonionic contrast agents

  10. Interactions of ionic and nonionic contrast agents with thrombolytic agents

    International Nuclear Information System (INIS)

    Fareed, J.; Moncada, R.; Scanlon, P.; Hoppensteadt, D.; Huan, X.; Walenga, J.M.

    1987-01-01

    Both the ionic and nonionic intravascular contrast media have been used before and after the administration of thrombolytic agents to evaluate clot lysis during angioplasty and the treatment of myocardial infarction. In experimental animal models, the authors found that the clot lytic efficacy of streptokinase, streptokinase-plasminogen complex, and tissue plasminogen activator (t-PA) is markedly augmented if these agents are administered within 1 hour after the angiographic producers. Furthermore, contrast agents injected after the administration of t-Pa exhibit a synergistic action. In stimulated models administration of one ionic contrast medium (Angiovist, Berlex, Wayne, NJ) and two nonionic contrast agents (Isovue-370, Squibb Diagnostics, New Brunswick, NJ; Omnipaque-350, Winthrop, NY) 15 minutes before the administration of t-PA resulted in marked enhancement of the lytic activity. Although the mechanism of this interaction is unknown at this time, it should be taken into consideration in the treatment of patients with myocardial infarction, in whom contrast agents are continually used to evaluate the therapeutic lysis. Furthermore, this interaction may be partly related to the therapeutic efficacy and/or hemorrhagic actions observed

  11. MR tomography of focal liver lesions using the superparamagnetic contrast agent AMI-25 at 1.5 tesla

    International Nuclear Information System (INIS)

    Duda, S.H.; Laniado, M.; Kopp, A.F.; Groenewaeller, E.; Aicher, K.P.; Pavone, P.; Jehle, E.; Claussen, C.D.

    1994-01-01

    Superparamagnetic iron oxide particles (AMI-25) were evaluated as a liver contrast agent in high-field MR imaging (1.5 T). 16 patients with up to 5 presumed focal liver lesions (liver metastases n=8, HCC n=5, Klatskin tumours n=2, FNH n=1) received 15 μmol Fe/kg BW intravenously and were examined via standard T 1 - and T 2 -weighted spin-echo sequences. Quantitative image analysis showed a post-contrast increase of the contrast-to-noise ratio (C/N) from 1.6 to 7.4 on SE 2,500/15 images (p [de

  12. The significance of the allergy history in the use of intravenous X-ray contrast media

    International Nuclear Information System (INIS)

    Schmidt, M.; Kroczek, U.

    1986-01-01

    A restrospective study correlating allergy histories and reactions to X-ray contrast media was performed with a study group containing 519 patients receiving intravenous and infusion cholangiograms and 827 patients receiving intravenous and infusion pyelograms. Reactions against X-ray contrast media were observed significantly more frequently among patients with a positive allergy history independent of the suspected allergy (p [de

  13. The usefulness of US with contrast agent on breast tumors

    International Nuclear Information System (INIS)

    Jung, Hye An; Jung, Jung Im; Kim, Hak Hee; Son, Sang Bum; Byun, Jae Young; Lee, Jae Mun; Hahn, Sung Tae; Kim, Choon Yul

    2000-01-01

    To evaluate the usefulness of US with contrast agent breast tumors. Fifteen breast tumors in fourteen patients underwent color Doppler US before and after intravenous injection of a microbubble contrast agent (Levovist, Schering AG, Berlin, Germany). Benign lesions were 8 and malignant lesions were 7 among these. Real-time power Doppler ultrasonographic images were recorded on a videotape and representative images were color-printed. Tumor vascularity was analyzed on real-time images in regard to its presence or absence, and changes in diameter and number of vessels, presence or absence of blush around the vessels. Two observers reached a consensus. Results of malignant tumors were compared with those of benign tumors. Color Doppler signal intensity increased in 12 of 15 cases (80%). Number of vessel increased in 9 of 15 cases (60%) and diameter of vessel increased in 12 of 15 cases (80%). Vascular blush around the enhanced vessel was present in 5 of 15 patients (53%). Color Doppler signal increased in 5 of 8 benign lesions (63%) and 7 of 7 malignant lesions (100%). Number of vessel increased in 4 of 8 benign lesion (50%) and 5 of 7 malignant lesions (71%). Diameter of vessel increased in 5 of 8 benign lesions (63%) and 7 of 7 malignant lesions (100%). Blush around the enhanced vessel was present in one of 8 benign lesions (13%) and 4 of 7 malignant lesions (57%). The time to peak enhancement was shorter in malignant cases (mean=45 sec) than benign cases (mean=82 sec). US with contrast agent on breast tumors is effective to detect blood flow within the mass and may be helpful to differentiate malignant from benign lesions.

  14. Life-Threatening Thrombocytopenia Following Intravenous Contrast Media Infusion.

    Science.gov (United States)

    Park, Mihwa; Kim, Minjeong; Park, Jisun; Cho, Jinhyun

    2018-01-01

    Radiocontrast media-induced acute severe thrombocytopenia is a very rare complication and potentially life-threatening. Here, we report the case of a 63-year-old male patient with severe acute thrombocytopenia following first exposure to intravenous non-ionic contrast media without immediate allergic reactions. His platelet count dropped from 107000/μL to 2000/μL after six hours of radiocontrast infusion. After administration of corticosteroid and transfusion of platelet concentrates, the platelet count returned gradually to normal within 5 days. To the best of our knowledge, non-ionic contrast media-induced isolated acute severe thrombocytopenia following no signs or symptoms of immediate allergic reaction has never been described. © Copyright: Yonsei University College of Medicine 2018.

  15. Influence of hyperosmotic agent (glycerol) in contrast enhancement

    International Nuclear Information System (INIS)

    Moriyama, Takashi; Suzuki, Shigeharu; Nakaoka, Tsutomu

    1981-01-01

    For getting a better contrast enhancement (CE) of computed tomography (CT) in brain tumors, we tried to increase the extravascular iodine concentration. A vailing ourselves of the period of returning water following intravenously administered glycerol, a drip injection of the contrast medium gave a better CE effect than the usual CE. In two benign gliomas, CE with glycerol was much better than CE without glycerol, and in two malignant gliomas and two metastatic tumors, CE with glycerol was better, but not so much better as with the benign tumors. In general, the CE effect in primary brain tumors showed a decreasing pattern, whereas in metastatic brain tumors the best time was 60 minutes after the injection of the contrast material (increasing and decreasing pattern), suggesting an increase in the extravascular iodine and a severe failure of the blood brain barrier. Two cystic malignant gliomas allowed the intravenously injected contrast medium to enter the cysts. It appears that the contrast medium passes through and/or is secreted from the wall of the cyst. (author)

  16. CT angiography. Abdominal CT using intravenous aortography for contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Nagai, J; Nakauma, Y; Egawa, J; Kawamura, M [Teikyo Univ., Tokyo (Japan). Faculty of Medicine

    1980-04-01

    To obtain imaging effects close to those of abdominal aortography and investigate a technique with little invasion to patients, intravenous aortography was applied to contrast enhancement (CE) in abdominal CT, and its usefulness was discussed. Intravenous aortography could clearly visualize lesions with rich neovascularity such as hepatocellular carcinoma and renal cell carcinoma. Differing from a drip infusion method, this method has complexities in its technique that contrast medium is injected at once, blood circulation time which is represented by the time between the injection and the time when the patients feel bitterness (10 - 12 seconds) must be measured before CE, and scanning begins 2 seconds before the patients feel bitterness. However, the invasion to patients due to this method is slight, and the capacity of this method to visualize neovascularity is superior to CE by a drip infusion method. Therefore, qualitative diagnosis by CT will be improved by using this method together with a drip infusion method.

  17. Effect of intravenous contrast agent volume on colorectal cancer vascular parameters as measured by perfusion computed tomography

    International Nuclear Information System (INIS)

    Goh, V.; Bartram, C.; Halligan, S.

    2009-01-01

    Aim: To determine the effect of two different contrast agent volumes on quantitative and semi-quantitative vascular parameters as measured by perfusion computed tomography (CT) in colorectal cancer. Materials and methods: Following ethical approval and informed consent, eight prospectively recruited patients with proven colorectal adenocarcinoma underwent two separate perfusion CT studies on the same day after (a) 100 ml and (b) 50 ml of a 340 mg/ml iodinated contrast medium, respectively. Quantitative (blood volume, blood flow, permeability surface area product) and semi-quantitative (peak enhancement, time to peak enhancement) tumour vascular parameters were determined using commercial software based on distributed parameter analysis and compared using t-testing. Results: Tumour blood volume, blood flow, and permeability surface area product were not substantially different following the injection of 100 ml and 50 ml contrast medium: 6.12 versus 6.23 ml/100 g tissue; 73.4 versus 71.3 ml/min/100 g tissue; 15.6 versus 15.3 ml/min/100 g tissue for 100 and 50 ml, respectively; p > 0.05. Tumour peak enhancement and time to peak were significantly greater following the injection of 100 ml versus 50 ml contrast medium: 41.2 versus 28.5 HU; 16.1 versus 11.8 s for 100 ml and 50 ml, respectively; p = 0.002; p = 0.0003. Conclusion: Quantitative parameters do not appear to change substantially with a higher contrast agent volume suggesting a combined diagnostic staging-perfusion CT study following a single injection is feasible for colorectal cancer

  18. Contrast-enhanced peripheral MRA

    DEFF Research Database (Denmark)

    Nielsen, Yousef W; Thomsen, Henrik S

    2012-01-01

    MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic......-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged...... intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal...

  19. Iodinated contrast media and contrast-induced nephropathy: is there a preferred cost-effective agent?

    Science.gov (United States)

    Sharma, Samin K

    2008-05-01

    Over 20 years have passed since the introduction of the tri-iodinated low-osmolar nonionic contrast agents such as iopamidol, iohexol, ioversol and iopromide. During this time, most cardiology practices have switched to these nonionic agents to avoid the nuisance side effects and cardiac adverse events associated with the older ionic contrast agents. Although the improved tolerability of the nonionic agents is generally attributed to their decreased osmolality (approximately half that of the older ionic contrast agents), in fact, these contrast agents also differ from the older agents in their ionicity, viscosity and direct chemotoxicity. The impact of these properties on safety, together with cost differences, should be considered when selecting a contrast agent.

  20. Dendrimer-based Macromolecular MRI Contrast Agents: Characteristics and Application

    Directory of Open Access Journals (Sweden)

    Hisataka Kobayashi

    2003-01-01

    Full Text Available Numerous macromolecular MRI contrast agents prepared employing relatively simple chemistry may be readily available that can provide sufficient enhancement for multiple applications. These agents operate using a ~100-fold lower concentration of gadolinium ions in comparison to the necessary concentration of iodine employed in CT imaging. Herein, we describe some of the general potential directions of macromolecular MRI contrast agents using our recently reported families of dendrimer-based agents as examples. Changes in molecular size altered the route of excretion. Smaller-sized contrast agents less than 60 kDa molecular weight were excreted through the kidney resulting in these agents being potentially suitable as functional renal contrast agents. Hydrophilic and larger-sized contrast agents were found better suited for use as blood pool contrast agents. Hydrophobic variants formed with polypropylenimine diaminobutane dendrimer cores created liver contrast agents. Larger hydrophilic agents are useful for lymphatic imaging. Finally, contrast agents conjugated with either monoclonal antibodies or with avidin are able to function as tumor-specific contrast agents, which also might be employed as therapeutic drugs for either gadolinium neutron capture therapy or in conjunction with radioimmunotherapy.

  1. Non-radiological contrast agents (MRI)

    International Nuclear Information System (INIS)

    Bonnemain, B.; Lautrou, J.; Meyer, D.; Doucet, D.

    1987-01-01

    Over the past few years, extensive research has been carried out in an attempt to develop contrast agents that could help improve both the performance (acquisition times) and the diagnostic efficacy of Magnetic Resonance Imaging (MRI) techniques. On the basis of physicochemical and pharmacological criteria discussed in this presentation, a few efficacious, well-tolerated compounds could be developed. Two of them, the gadolinium complexes Gd-DOTA and Gd-DTPA, are currently being tried in man. This first generation of contrast agents, which are aspecific markers of the intravascular space, has been shown to have good diagnostic potential in conventional MRI procedures. The diagnostic contribution of these contrast agents will probably be a most essential factor in new MRI techniques using low field strengh or fast imaging sequences [fr

  2. Advice on the management of reactions to intravenous contrast media

    International Nuclear Information System (INIS)

    1996-01-01

    The College has previously issued guidelines for the management of adverse reactions to intravenous ionic and non-ionic contrast media. The following updated guidelines are applicable to both children and adults. The reported adverse reaction rate to conventional ionic contrast media is about 5%, the vast majority of reactions being of a minor nature, and to the newer non-ionic contrast media, approximately 1%. The rare serious reaction, with an estimated incidence of 0.05% with ionic contrast media and substantially less with non-ionic media, must be treated quickly and appropriately. Identification and symptomatic characterisation of the reaction are the key first steps and should be followed by ad hoc management based on general principles. (author)

  3. Microbubbles as contrast agent for in-line x-ray phase-contrast imaging

    International Nuclear Information System (INIS)

    Xi Yan; Zhao Jun; Tang Rongbiao; Wang Yujie

    2011-01-01

    In the present study, we investigated the potential of gas-filled microbubbles as contrast agents for in-line x-ray phase-contrast imaging (PCI) in biomedical applications. When imaging parameters are optimized, the microbubbles function as microlenses that focus the incoming x-rays to form bright spots, which can significantly enhance the image contrast. Since microbubbles have been shown to be safe contrast agents in clinical ultrasonography, this contrast-enhancement procedure for PCI may have promising utility in biomedical applications, especially when the dose of radiation is a serious concern. In this study, we performed both numerical simulations and ex vivo experiments to investigate the formation of the contrast and the effectiveness of microbubbles as contrast agents in PCI.

  4. Method and apparatus to characterize ultrasonically reflective contrast agents

    Science.gov (United States)

    Pretlow, Robert A., III (Inventor)

    1993-01-01

    A method and apparatus for characterizing the time and frequency response of an ultrasonically reflective contrast agent is disclosed. An ultrasonically reflective contrast agent is injected, under constant pressure, into a fluid flowing through a pump flow circuit. The fluid and the ultrasonically reflective contrast agent are uniformly mixed in a mixing chamber, and the uniform mixture is passed through a contrast agent chamber. The contrast agent chamber is acoustically and axially interposed between an ultrasonic transducer chamber and an acoustic isolation chamber. A pulse of ultrasonic energy is transmitted into the contrast agent chamber from the ultrasonic transducer chamber. An echo waveform is received from the ultrasonically reflective contrast agent, and it is analyzed to determine the time and frequency response of the ultrasonically reflective contrast agent.

  5. Intravenous vs. left ventricular injection of ionic contrast material: hemodynamic implications for digital subtraction angiography

    International Nuclear Information System (INIS)

    Mancini, G.B.; Ostrander, D.R.; Slutsky, R.A.; Shabetai, R.; Higgins, C.B.

    1983-01-01

    Because of the increased use of intravenous injection of contrast material for the evaluation of cardiac structure and function by digital subtraction techniques, a study was done to assess the hemodynamic effects of contrast material when used in this fashion in man. In 10 patients, with each serving as his own control, the effects of intravenous and intraventricular injections of sodium meglumine diatrizoate (Renografin 76) in the same dose were compared. There was no difference between these two methods with respect to changes in pulmonary wedge pressures, systemic pressures, and pulmonary vascular resistance. The elevation of mean pulmonary artery and right atrial pressure was greater after the intraventricular injection (p <0.05). The elevated cardiac output and systemic vascular resistance returned to control values somewhat more quickly after the intravenous injection (p<0.001 and p<0.05, respectively); and the increase in cardiac output was greater after the intravenous injection at 1 min (p<0.05), but less than after the intraventricular injection at 2 min (p<0.05). Despite the detection of these statistically significant differences, the magnitude and timing of these differences are too small to justify the notion that imaging by intravenous injections of standard ionic contrast media provides any substantial hemodynamic benefits or decreased risk to the patient

  6. Trends and developments in MRI contrast agent research

    International Nuclear Information System (INIS)

    Cavagna, F.M.; Dapra, M.; Castelli, P.M.; Maggioni, F.; Kirchin, M.A.

    1997-01-01

    The currently prevailing trends in industrial contrast agent research for MRI are discussed. Specific mention is made of contrast agents for liver imaging using both static and delayed procedures, of the potential for blood pool agents and the form such agents may take, and of the ultimate challenge for contrast agent R and D: tissue-targeting in a wider sense to both normal and pathologic tissues. (orig.)

  7. Hepatobiliary contrast agents for contrast-enhanced MRI of the liver: properties, clinical development and applications

    International Nuclear Information System (INIS)

    Reimer, Peter; Schneider, Guenter; Schima, Wolfgang

    2004-01-01

    Hepatobiliary contrast agents with uptake into hepatocytes followed by variable biliary excretion represent a unique class of cell-specific MR contrast agents. Two hepatobiliary contrast agents, mangafodipir trisodium and gadobenate dimeglumine, are already clinically approved. A third hepatobiliary contrast agent, Gd-EOB-DTPA, is under consideration. The purpose of this review is to provide an overview on the properties, clinical development and application of these three hepatobiliary contrast agents. Bolus injectable paramagnetic hepatobiliary contrast agents combine established features of extracellular agents with the advantages of hepatocyte specificity. The detection and characterisation of focal liver disease appears to be improved compared to unenhanced MRI, MRI with unspecific contrast agents and contrast-enhanced CT. To decrease the total time spent by a patient in the MR scanner, it is advisable to administer the agent immediately after acquisition of unenhanced T1-w MRI. After infusion or bolus injection (with dynamic FS-T1-w 2D or 3D GRE) of the contrast agent, moderately and heavily T2w images are acquired. Post-contrast T1-w MRI is started upon completion of T2-w MRI for mangafodipir trisodium and Gd-EOB-DTPA as early as 20 min following injection, while gadobenate dimeglumine scans are obtained >60 min following injection. Post-contrast acquisition techniques with near isotropic 3D pulse sequences with fat saturation parallel the technical progress made by MSCT combined with an unparalleled improvement in tumour-liver contrast. The individual decision that hepatobiliary contrast agent one uses is partly based on personal preferences. No comparative studies have been conducted comparing the advantages or disadvantages of all three agents directly against each other. (orig.)

  8. Synchrotron-based intra-venous K-edge digital subtraction angiography in a pig model: A feasibility study

    International Nuclear Information System (INIS)

    Schueltke, Elisabeth; Fiedler, Stefan; Nemoz, Christian; Ogieglo, Lissa; Kelly, Michael E.; Crawford, Paul; Esteve, Francois; Brochard, Thierry; Renier, Michel; Requardt, Herwig; Le Duc, Geraldine; Juurlink, Bernhard; Meguro, Kotoo

    2010-01-01

    Background: K-edge digital subtraction angiography (KEDSA) combined with the tunability of synchrotron beam yields an imaging technique that is highly sensitive to low concentrations of contrast agents. Thus, contrast agent can be administered intravenously, obviating the need for insertion of a guided catheter to deliver a bolus of contrast agent close to the target tissue. With the high-resolution detectors used at synchrotron facilities, images can be acquired at high spatial resolution. Thus, the KEDSA appears particularly suited for studies of neurovascular pathology in animal models, where the vascular diameters are significantly smaller than in human patients. Materials and methods: This feasibility study was designed to test the suitability of KEDSA after intravenous injection of iodine-based contrast agent for use in a pig model. Four adult male pigs were used for our experiments. Neurovascular angiographic images were acquired using KEDSA with a solid state Germanium (Ge) detector at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. Results: After intravenous injection of 0.9 ml/kg iodinated contrast agent (Xenetix), the peak iodine concentrations in the internal carotid and middle cerebral arteries reached 35 mg/ml. KEDSA images in radiography mode allowed the visualization of intracranial arteries of less than 1.5 mm diameter.

  9. Synchrotron-based intra-venous K-edge digital subtraction angiography in a pig model: a feasibility study.

    Science.gov (United States)

    Schültke, Elisabeth; Fiedler, Stefan; Nemoz, Christian; Ogieglo, Lissa; Kelly, Michael E; Crawford, Paul; Esteve, Francois; Brochard, Thierry; Renier, Michel; Requardt, Herwig; Le Duc, Geraldine; Juurlink, Bernhard; Meguro, Kotoo

    2010-03-01

    K-edge digital subtraction angiography (KEDSA) combined with the tunability of synchrotron beam yields an imaging technique that is highly sensitive to low concentrations of contrast agents. Thus, contrast agent can be administered intravenously, obviating the need for insertion of a guided catheter to deliver a bolus of contrast agent close to the target tissue. With the high-resolution detectors used at synchrotron facilities, images can be acquired at high spatial resolution. Thus, the KEDSA appears particularly suited for studies of neurovascular pathology in animal models, where the vascular diameters are significantly smaller than in human patients. This feasibility study was designed to test the suitability of KEDSA after intravenous injection of iodine-based contrast agent for use in a pig model. Four adult male pigs were used for our experiments. Neurovascular angiographic images were acquired using KEDSA with a solid state Germanium (Ge) detector at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. After intravenous injection of 0.9 ml/kg iodinated contrast agent (Xenetix), the peak iodine concentrations in the internal carotid and middle cerebral arteries reached 35 mg/ml. KEDSA images in radiography mode allowed the visualization of intracranial arteries of less than 1.5mm diameter. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  10. Synchrotron-based intra-venous K-edge digital subtraction angiography in a pig model: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Schueltke, Elisabeth [Departments of Surgery, University of Saskatchewan, Saskatoon, SK (Canada); Anatomy and Cell Biology, University of Saskatchewan, Saskatoon, SK (Canada); Department of Neurological Sciences, Walton Medical Centre, University of Liverpool, Liverpool L97 LJ (United Kingdom)], E-mail: e.schultke@usask.ca; Fiedler, Stefan [European Molecular Biology Laboratory (EMBL), Nottkestrasse 85, 22603 Hamburg (Germany); Nemoz, Christian [European Synchrotron Radiation Facility (ESRF), 6 rue Horowitz, 38043 Grenoble (France); Ogieglo, Lissa [Departments of Surgery, University of Saskatchewan, Saskatoon, SK (Canada); Kelly, Michael E. [Departments of Surgery, University of Saskatchewan, Saskatoon, SK (Canada); Department of Neurosurgery, Section of Cerebrovascular and Endovascular Neurosurgery, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH (United States); Crawford, Paul [Royal Veterinary College, Hawkshead Lane, North Mymms, Hatfield, Herfordshire AL9 7TA (United Kingdom); Esteve, Francois [INSERM U836-ESRF, 6 rue Horowitz, 38043 Grenoble (France); Brochard, Thierry; Renier, Michel; Requardt, Herwig; Le Duc, Geraldine [European Synchrotron Radiation Facility (ESRF), 6 rue Horowitz, 38043 Grenoble (France); Juurlink, Bernhard [Anatomy and Cell Biology, University of Saskatchewan, Saskatoon, SK (Canada); Meguro, Kotoo [Departments of Surgery, University of Saskatchewan, Saskatoon, SK (Canada)

    2010-03-15

    Background: K-edge digital subtraction angiography (KEDSA) combined with the tunability of synchrotron beam yields an imaging technique that is highly sensitive to low concentrations of contrast agents. Thus, contrast agent can be administered intravenously, obviating the need for insertion of a guided catheter to deliver a bolus of contrast agent close to the target tissue. With the high-resolution detectors used at synchrotron facilities, images can be acquired at high spatial resolution. Thus, the KEDSA appears particularly suited for studies of neurovascular pathology in animal models, where the vascular diameters are significantly smaller than in human patients. Materials and methods: This feasibility study was designed to test the suitability of KEDSA after intravenous injection of iodine-based contrast agent for use in a pig model. Four adult male pigs were used for our experiments. Neurovascular angiographic images were acquired using KEDSA with a solid state Germanium (Ge) detector at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. Results: After intravenous injection of 0.9 ml/kg iodinated contrast agent (Xenetix), the peak iodine concentrations in the internal carotid and middle cerebral arteries reached 35 mg/ml. KEDSA images in radiography mode allowed the visualization of intracranial arteries of less than 1.5 mm diameter.

  11. Gadolinium labeled pharmaceuticals as potential MRI contrast agents for liver and biliary tract

    International Nuclear Information System (INIS)

    Najafi, A.; Amparo, E.G.; Johnson, R.F. Jr.

    1987-01-01

    Three gadolinium-labeled compounds, potential nuclear magnetic resonance (NMR) imaging contrast agents for liver and biliary tract, were studied: 1) Gd-DISIDA, 2) Gd-DTPA-Liposomes, and 3) Gd-DTPA dihexadecylamide (Gd-diamide). In each case, ''Carrier Added'' Gd-153 with specific activity of about 5uCi/mg was used. Each labeled compound was evaluated in experimental animals. Gd-DISIDA proved unsatisfactory because of in vivo instability. Gd-DTPA-Liposomes demonstrated strong toxic effects probably due to pulmonary embolism when large amounts of this compound was administered intravenously. Gd-diamide showed good uptake in the hepatocytes with subsequent excretion into the biliary tract. Several rabbits were imaged in a 0.6T NMR imaging system before and after injection of Gd-diamide. Pulse sequences were chosen that would yield T1-weighted images and permit calculation of T1 relaxation times. This compound produced significant shortening of the T1 relaxation times of the liver and observable increase in intensity on the T1-weighted images. Gd-diamide shows promise as potential NMR contrast agent for liver and biliary tract imaging. (author)

  12. Cell tracking with gadophrin-2: a bifunctional contrast agent for MR imaging, optical imaging, and fluorescence microscopy

    International Nuclear Information System (INIS)

    Daldrup-Link, Heike E.; Rudelius, Martina; Piontek, Guido; Schlegel, Juergen; Metz, Stephan; Settles, Marcus; Rummeny, Ernst J.; Pichler, Bernd; Heinzmann, Ulrich; Oostendorp, Robert A.J.

    2004-01-01

    The purpose of this study was to assess the feasibility of use of gadophrin-2 to trace intravenously injected human hematopoietic cells in athymic mice, employing magnetic resonance (MR) imaging, optical imaging (OI), and fluorescence microscopy. Mononuclear peripheral blood cells from GCSF-primed patients were labeled with gadophrin-2 (Schering AG, Berlin, Germany), a paramagnetic and fluorescent metalloporphyrin, using established transfection techniques with cationic liposomes. The labeled cells were evaluated in vitro with electron microscopy and inductively coupled plasma atomic emission spectrometry. Then, 1 x 10 6 -3 x 10 8 labeled cells were injected into 14 nude Balb/c mice and the in vivo cell distribution was evaluated with MR imaging and OI before and 4, 24, and 48 h after intravenous injection (p.i.). Five additional mice served as controls: three mice were untreated controls and two mice were investigated after injection of unlabeled cells. The contrast agent effect was determined quantitatively for MR imaging by calculating signal-to-noise-ratio (SNR) data. After completion of in vivo imaging studies, fluorescence microscopy of excised organs was performed. Intracellular cytoplasmatic uptake of gadophrin-2 was confirmed by electron microscopy. Spectrometry determined an uptake of 31.56 nmol Gd per 10 6 cells. After intravenous injection, the distribution of gadophrin-2 labeled cells in nude mice could be visualized by MR, OI, and fluorescence microscopy. At 4 h p.i., the transplanted cells mainly distributed to lung, liver, and spleen, and 24 h p.i. they also distributed to the bone marrow. Fluorescence microscopy confirmed the distribution of gadophrin-2 labeled cells to these target organs. Gadophrin-2 is suited as a bifunctional contrast agent for MR imaging, OI, and fluorescence microscopy and may be used to combine the advantages of each individual imaging modality for in vivo tracking of intravenously injected hematopoietic cells. (orig.)

  13. Computer-assisted quantitative assessment of power Doppler US: effects of microbubble contrast agent in the differentiation of breast tumors

    International Nuclear Information System (INIS)

    Kettenbach, Joachim; Helbich, Thomas H.; Huber, Sabine; Zuna, Ivan; Dock, Wolfgang

    2005-01-01

    Rationale and objectives: To objectively quantify the effects of a microbubble contrast agent to differentiate breast tumors with power doppler ultrasound and to compare these results with color doppler ultrasound (CD US). Methods: In 47 patients a microbubble contrast agent was injected intravenously. Computer-assisted quantitative assessment of the color pixel density was performed to evaluate the increase in Doppler signals. Results were compared to previously published results of a color Doppler ultrasound study. Results: Peak color pixel density at contrast-enhanced power Doppler ultrasound was higher for carcinomas than for benign tumors (P < 0.03). Time to peak enhancement was shorter in carcinomas than in benign tumors (P < 0.01). For both parameters, diagnostic accuracy of power Doppler ultrasound was 69 and 78%, and for color Doppler ultrasound 62 and 76%, respectively. Conclusions: Quantitative assessment of contrast-enhanced power Doppler ultrasound showed significant differences in malignant and benign breast tumors. Diagnostic accuracy of contrast-enhanced power Doppler ultrasound was higher compared to color Doppler ultrasound

  14. Contrast induced nephropathy in patients undergoing intravenous (IV) contrast enhanced computed tomography (CECT) and the relationship with risk factors: a meta-analysis

    NARCIS (Netherlands)

    Moos, Shira I.; van Vemde, David N. H.; Stoker, Jaap; Bipat, Shandra

    2013-01-01

    To summarize the incidence of contrast-induced nephropathy (CIN) and associations between CIN incidence and risk factors in patients undergoing intravenous contrast-enhanced computed tomography (CECT) with low- or iso-osmolar iodinated contrast medium. This review is performed in accordance with the

  15. Magnetic resonance imaging contrast agents: Overview and perspectives

    International Nuclear Information System (INIS)

    Yan Guoping; Robinson, Leslie; Hogg, Peter

    2007-01-01

    Magnetic resonance imaging (MRI) is a non-invasive clinical imaging modality, which has become widely used in the diagnosis and/or staging of human diseases around the world. Some MRI examinations include the use of contrast agents. The categorizations of currently available contrast agents have been described according to their effect on the image, magnetic behavior and biodistribution in the body, respectively. In this field, superparamagnetic iron oxide particles and soluble paramagnetic metal chelates are two main classes of contrast agents for MRI. This review outlines the research and development of MRI contrast agents. In future, the ideal MRI contrast agent will be focused on the neutral tissue- or organ-targeting materials with high relaxivity and specificity, low toxicity and side effects, suitable long intravascular duration and excretion time, high contrast enhancement with low dose in vivo, and with minimal cost

  16. Use of contrast agents for liver MRI

    International Nuclear Information System (INIS)

    Ward, Janice

    2007-01-01

    Contrast-enhanced MRI is recognised as one of the most accurate imaging methods for investigating diseases of the liver. Uniquely several different types of contrast agents are available for liver MRI. They can be divided into non-specific extracellular fluid space (ECF), hepatocyte specific and reticulo-endothelial system (RES) specific agents. They are used to improve the detection of focal liver lesions by increasing normal-abnormal tissue contrast and to assist in lesion characterisation by demonstrating tissue perfusion and cellular function. ECF-gadolinium (Gd) chelates have been widely used in abdominal MRI for many years. They provide valuable information regarding the vascularisation and perfusion characteristics of lesions and assist in lesion detection, particularly of hypervascular lesions. The hepatocyte and RES-specific agents further improve lesion detection, provide important functional information and allow the distinction between hepatocellular and non-hepatocellular tumours. This article describes the different MR contrast agents and discusses their current status for diagnosing focal liver lesions. The importance of optimised technique and appropriate selection of contrast agent is emphasised

  17. Correlating intravenous radiographic contrast media reactions with the allergic profile

    International Nuclear Information System (INIS)

    Chua-Lim, A.; Enright, T.; Duda, E.; Lim, D.T.

    1987-01-01

    To determine the relevance of allergy as a predisposing factor in reactions to radiographic contrast media, the authors investigated the incidence of allergy among 100 randomly selected patients undergoing intravenous excretory urography and CT. The study population consisted of 50 reactors and 50 nonreactos to radiographic contrast media. All 100 subjects completed an allergy history, percutaneous allergy tests, and an in vitro specific IgE assay to common allergens. Thirty-four of 50 reactors had a positive allergy history, in contrast to 15 of 50 nonreactors (P < .001). Twenty-seven reactors had positive skin tests, in contrast to 12 of 50 nonreactors (P < .005). In vitro IgE assay results are pending. The results indicate that patients with positive histories or positive skin tests or both are at an increased risk for reactions to radiographic contrast media

  18. Effect of microbubble contrast agent during high intensity focused ultrasound ablation on rabbit liver in vivo

    International Nuclear Information System (INIS)

    Chung, Dong Jin; Cho, Se Hyun; Lee, Jae Mun; Hahn, Seong-Tae

    2012-01-01

    Objective: To evaluate the effect of a microbubble contrast agent (SonoVue) during HIFU ablation of a rabbit liver. Materials and methods: HIFU ablations (intensity of 400 W/cm 2 for 4 s, six times, with a 5 s interval between exposures) were performed upon 16 in vivo rabbit livers before and after intravenous injection of a microbubble contrast agent (0.8 ml). A Wilcoxon signed rank test was used to compare mean ablation volume and time required to tissue ablation on real-time US. Shape of ablation and pattern of coagulative necrosis were analyzed by Fisher's exact test. Results: The volume of coagulative necrosis was significantly larger in the combination microbubble and HIFU group than in the HIFU alone group (P < 0.05). Also, time to reach ablation was shorter in the combination microbubble and HIFU group than in the HIFU alone group (P < 0.05). When analyzing the shape of tissue ablation, a pyramidal shape was more prevalently in the HIFU alone group compared to the combination microbubble and HIFU group (P < 0.05). Following an analysis of the pattern of coagulative necrosis, non-cavitary necrosis was found in ten and cavitary necrosis in six of the samples in the combination microbubble and HIFU group. Conversely, non-cavitary necrosis occurred in all 16 samples in the HIFU alone group (P < 0.05). Conclusion: HIFU of in vivo rabbit livers with a microbubble contrast agent produced larger zones of ablation and more cavitary tissue necrosis than without the use of a microbubble contrast agent. Microbubble contrast agents may be useful in tissue ablation by enhancing the treatment effect of HIFU.

  19. Fundamental study of DSA images using gadolinium contrast agent

    International Nuclear Information System (INIS)

    Nagashima, Hiroyuki; Shiraishi, Akihisa; Igarashi, Hitoshi; Sakamoto, Hajime; Sano, Yoshitomo

    2002-01-01

    Most contrast agents used in digital subtraction angiography (DSA) are non-ionic iodinated contrast agents, which can cause severe side effects in patients with contraindications for iodine or allergic reactions to iodine. Therefore, DSA examinations using carbon dioxide gas or examinations done by magnetic resonance imaging (MRI) and ultrasound (US) were carried out in these patients. However, none of these examinations provided mages as clear as those of DSA with an iodinated contrast agent. We experienced DSA examination using a gadolinium contrast agent in a patient contraindicated for iodine. The patient had undergone MRI examination with a gadolinium contrast agent previously without side effects. The characteristics of gadolinium and the iodinated contrast agent were compared, and the DSA images obtained clinically using these media were also evaluated. The signal-to-noise (SN) ratio of the gadolinium contrast agent was the highest at tube voltages of 70 to 80 kilovolts and improved slightly when the image intensifier (I.I.) entrance dose was greater than 300 μR (77.4 nC/kg). The dilution ratios of five iodinated contrast agents showed the same S/N value as the undiluted gadolinium contrast agent. Clinically, the images obtained showed a slight decrease in contrast but provided the data necessary to make a diagnosis and made it possible to obtain interventional radiology (IVR) without any side effects. DSA examinations using a gadolinium contrast agent have some benefit with low risk and are thought to be useful for patients contraindicated for iodine. (author)

  20. Intravenous contrast injection significantly affects bone mineral density measured on CT

    Energy Technology Data Exchange (ETDEWEB)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J.J.; Hoesein, Firdaus A.A.M.; Jong, Pim A. de [University Medical Center Utrecht, Department of Radiology and Internal Medicine-Geriatrics, Postbus 85500, Postbox: E.03.511, GA, Utrecht (Netherlands)

    2014-09-05

    The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. One hundred and fifty-two patients (99 without and 53 with malignant neoplasm) who underwent both unenhanced and two contrast-enhanced (arterial and portal venous phase) abdominal CT examinations in a single session between June 2011 and July 2013 were included. BMD was evaluated on the three examinations as CT-attenuation values in Hounsfield Units (HU) in the first lumbar vertebra (L1). CT-attenuation values were significantly higher in both contrast-enhanced phases, compared to the unenhanced phase (p < 0.01). In patients without malignancies, mean ± standard deviation (SD) HU-values increased from 128.8 ± 48.6 HU for the unenhanced phase to 142.3 ± 47.2 HU for the arterial phase and 147.0 ± 47.4 HU for the portal phase (p < 0.01). In patients with malignancies, HU-values increased from 112.1 ± 38.1 HU to 126.2 ± 38.4 HU and 130.1 ± 37.3 HU (p < 0.02), respectively. With different thresholds to define osteoporosis, measurements in the arterial and portal phase resulted in 7-25 % false negatives. Our study showed that intravenous contrast injection substantially affects BMD-assessment on CT and taking this into account may improve routine assessment of low BMD in nonquantitative CT. (orig.)

  1. Intravenous contrast injection significantly affects bone mineral density measured on CT

    International Nuclear Information System (INIS)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J.J.; Hoesein, Firdaus A.A.M.; Jong, Pim A. de

    2015-01-01

    The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. One hundred and fifty-two patients (99 without and 53 with malignant neoplasm) who underwent both unenhanced and two contrast-enhanced (arterial and portal venous phase) abdominal CT examinations in a single session between June 2011 and July 2013 were included. BMD was evaluated on the three examinations as CT-attenuation values in Hounsfield Units (HU) in the first lumbar vertebra (L1). CT-attenuation values were significantly higher in both contrast-enhanced phases, compared to the unenhanced phase (p < 0.01). In patients without malignancies, mean ± standard deviation (SD) HU-values increased from 128.8 ± 48.6 HU for the unenhanced phase to 142.3 ± 47.2 HU for the arterial phase and 147.0 ± 47.4 HU for the portal phase (p < 0.01). In patients with malignancies, HU-values increased from 112.1 ± 38.1 HU to 126.2 ± 38.4 HU and 130.1 ± 37.3 HU (p < 0.02), respectively. With different thresholds to define osteoporosis, measurements in the arterial and portal phase resulted in 7-25 % false negatives. Our study showed that intravenous contrast injection substantially affects BMD-assessment on CT and taking this into account may improve routine assessment of low BMD in nonquantitative CT. (orig.)

  2. Basic MR relaxation mechanisms and contrast agent design.

    Science.gov (United States)

    De León-Rodríguez, Luis M; Martins, André F; Pinho, Marco C; Rofsky, Neil M; Sherry, A Dean

    2015-09-01

    The diagnostic capabilities of magnetic resonance imaging (MRI) have undergone continuous and substantial evolution by virtue of hardware and software innovations and the development and implementation of exogenous contrast media. Thirty years since the first MRI contrast agent was approved for clinical use, a reliance on MR contrast media persists, largely to improve image quality with higher contrast resolution and to provide additional functional characterization of normal and abnormal tissues. Further development of MR contrast media is an important component in the quest for continued augmentation of diagnostic capabilities. In this review we detail the many important considerations when pursuing the design and use of MR contrast media. We offer a perspective on the importance of chemical stability, particularly kinetic stability, and how this influences one's thinking about the safety of metal-ligand-based contrast agents. We discuss the mechanisms involved in MR relaxation in the context of probe design strategies. A brief description of currently available contrast agents is accompanied by an in-depth discussion that highlights promising MRI contrast agents in the development of future clinical and research applications. Our intention is to give a diverse audience an improved understanding of the factors involved in developing new types of safe and highly efficient MR contrast agents and, at the same time, provide an appreciation of the insights into physiology and disease that newer types of responsive agents can provide. © 2015 Wiley Periodicals, Inc.

  3. Non-immunogenic dextran-coated superparamagnetic iron oxide nanoparticles: a biocompatible, size-tunable contrast agent for magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Unterweger H

    2017-07-01

    Full Text Available Harald Unterweger,1,* Christina Janko,1,* Marc Schwarz,2 László Dézsi,3 Rudolf Urbanics,4 Jasmin Matuszak,1 Erik Őrfi,3 Tamás Fülöp,3 Tobias Bäuerle,2 János Szebeni,3,4 Clément Journé,5 Aldo R Boccaccini,6 Christoph Alexiou,1 Stefan Lyer,1 Iwona Cicha1 1Cardiovascular Nanomedicine Unit, Section of Experimental Oncology und Nanomedicine (SEON, Else Kröner-Fresenius-Stiftung-Professorship, ENT Department, University Hospital Erlangen, Friedrich-Alexander-Universitaet Erlangen-Nuernberg, 2Preclinical Imaging Platform Erlangen (PIPE, Institute of Radiology, University Hospital Erlangen, Erlangen, Germany; 3Nanomedicine Research and Education Center, Semmelweis University, 4SeroScience Ltd., Budapest, Hungary; 5Inserm U1148, Fédération de Recherche en Imagerie Multimodalités (FRIM, X Bichat Hospital, Paris Diderot University, Paris, France; 6Institute of Biomaterials, Department of Materials Science and Engineering, University Erlangen-Nuremberg, Erlangen, Germany *These authors contributed equally to this work Abstract: Iron oxide-based contrast agents have been in clinical use for magnetic resonance imaging (MRI of lymph nodes, liver, intestines, and the cardiovascular system. Superparamagnetic iron oxide nanoparticles (SPIONs have high potential as a contrast agent for MRI, but no intravenous iron oxide-containing agents are currently approved for clinical imaging. The aim of our work was to analyze the hemocompatibility and immuno-safety of a new type of dextran-coated SPIONs (SPIONdex and to characterize these nanoparticles with ultra-high-field MRI. Key parameters related to nanoparticle hemocompatibility and immuno-safety were investigated in vitro and ex vivo. To address concerns associated with hypersensitivity reactions to injectable nanoparticulate agents, we analyzed complement activation-related pseudoallergy (CARPA upon intravenous administration of SPIONdex in a pig model. Furthermore, the size-tunability of SPIONdex and

  4. The interaction of MRI contrast agents with phospholipids

    International Nuclear Information System (INIS)

    Jendrasiak, Gordon L.; Smith, Ralph L.; Ribeiro, Anthony A.

    2000-01-01

    The molecular interactions of three clinically used MRI contrast agents with lipid vesicles, consisting of egg phosphatidylcholine (EPC), have been studied using high-field NMR techniques. At a molar ratio of one contrast agent molecule to five phospholipid molecules, a significant increase in the proton resonance line width occurred for certain lipid head group moieties. A large decrease in the T 1 relaxation times for the head group moieties was also observed. These two effects occurred regardless of the ionic status and the chelate structure of the three contrast agents. The structure of the contrast agents did, however, affect the magnitude of the two NMR parameter changes. These NMR effects also differed in magnitude amongst the various head group entities. The NMR effects were greatest for the head group moieties at or near the vesicle-water interface. The results are discussed in terms of the structure of the phospholipid-water interface. Since the use of contrast agents has become routine in clinical MRI, our results are of importance in terms of the interaction of the agents with physiological surfaces, many of which contain phospholipids. The understanding of such interactions should be of value not only for improved diagnostics, but also in the development of new contrast agents. (author)

  5. Contrast agent enhanced pQCT of articular cartilage

    Energy Technology Data Exchange (ETDEWEB)

    Kallioniemi, A S [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Jurvelin, J S [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Nieminen, M T [Department of Diagnostic Radiology, POB 50, 90029 OYS, Oulu University Hospital, Oulu (Finland); Lammi, M J [Department of Anatomy, Institute of Biomedicine, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Toeyraes, J [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland)

    2007-02-21

    The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T{sub 1,Gd} and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally

  6. Contrast agent enhanced pQCT of articular cartilage

    Science.gov (United States)

    Kallioniemi, A. S.; Jurvelin, J. S.; Nieminen, M. T.; Lammi, M. J.; Töyräs, J.

    2007-02-01

    The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T1,Gd and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n = 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r = -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally

  7. Contrast agent enhanced pQCT of articular cartilage

    International Nuclear Information System (INIS)

    Kallioniemi, A S; Jurvelin, J S; Nieminen, M T; Lammi, M J; Toeyraes, J

    2007-01-01

    The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T 1,Gd and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally degraded

  8. Contrast agent incompatibility with intravascular medications

    International Nuclear Information System (INIS)

    Irving, H.D.; Burbridge, B.E.

    1988-01-01

    In vitro and in vivo precipitation of iodinated contrast agents with commonly used medications have been reported. The intent of this in vitro study is to verify these reports and investigate other medications not previously tested. Contrast agents and medications were analyzed with a light spectrometer and observed for visible precipitates for up to 120 minutes. Previously reported incompatibilities were verified, and several new incompatibilities were discovered

  9. Informed consent for the administration of an intravenous contrast agent: importance and determinants of patient refusal; Consentimiento informado para la administracion de contraste intravenoso. Importancia y factores determinantes del rechazo por los pacientes

    Energy Technology Data Exchange (ETDEWEB)

    Martel, J. [Fundacion Hospital Alcorcon. Madrid (Spain); Garcia-Diaz, J. D. [Hospital Universitario Principe de Asturias. Alcala de Henares. Madrid (Spain)

    1999-07-01

    We proposed to determine the proportion of patients who refuse to undergo intravenous contrast administration and the factors that influence their refusal. Our series consisted of 442 patients who were supposed to undergo imaging studies involving the intravenous injection of an iodine contrast. In a personal interview, the patients were issued a questionnaire specifically designed for this study. The following parameters were recorded: sex, age, inpatient or outpatient status, medical history available, person who informed them about the procedure, person signing the informed consent (patient or other) , highest academic degree, attitude toward receiving the information and degree of concern after reading and signing the consent form. In our series 8.6% of the patients (95% confidence interval: 6-11.2) refused to sign the informed consent form. In addition, there were a number of patients who delayed the procedure or hindered the daily work schedule by some other means. When the relationship between each of the variables studied and refusal to sign the consent form was assessed, significant associations were observed between the latter and the academic level of the patient, his or her degree of concern and having received the information from a trained person. There was also a nearly significant trend toward the association between refusal and the patient's background. Relatively few patients refuse to sign the informed consent to receive intravenous contrast administration but this negative decision interferes with the health care practice. It is possible to identify certain correctable factors that influence the patient in this respect. (Author) 13 refs.

  10. Multiwalled carbon nanotube hybrids as MRI contrast agents

    Directory of Open Access Journals (Sweden)

    Nikodem Kuźnik

    2016-07-01

    Full Text Available Magnetic resonance imaging (MRI is one of the most commonly used tomography techniques in medical diagnosis due to the non-invasive character, the high spatial resolution and the possibility of soft tissue imaging. Contrast agents, such as gadolinium complexes and superparamagnetic iron oxides, are administered to spotlight certain organs and their pathologies. Many new models have been proposed that reduce side effects and required doses of these already clinically approved contrast agents. These new candidates often possess additional functionalities, e.g., the possibility of bioactivation upon action of particular stimuli, thus serving as smart molecular probes, or the coupling with therapeutic agents and therefore combining both a diagnostic and therapeutic role. Nanomaterials have been found to be an excellent scaffold for contrast agents, among which carbon nanotubes offer vast possibilities. The morphology of multiwalled carbon nanotubes (MWCNTs, their magnetic and electronic properties, the possibility of different functionalization and the potential to penetrate cell membranes result in a unique and very attractive candidate for a new MRI contrast agent. In this review we describe the different issues connected with MWCNT hybrids designed for MRI contrast agents, i.e., their synthesis and magnetic and dispersion properties, as well as both in vitro and in vivo behavior, which is important for diagnostic purposes. An introduction to MRI contrast agent theory is elaborated here in order to point to the specific expectations regarding nanomaterials. Finally, we propose a promising, general model of MWCNTs as MRI contrast agent candidates based on the studies presented here and supported by appropriate theories.

  11. High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted MR Images: Comparison between Gadobutrol and Linear Gadolinium-Based Contrast Agents.

    Science.gov (United States)

    Moser, F G; Watterson, C T; Weiss, S; Austin, M; Mirocha, J; Prasad, R; Wang, J

    2018-02-01

    In view of the recent observations that gadolinium deposits in brain tissue after intravenous injection, our aim of this study was to compare signal changes in the globus pallidus and dentate nucleus on unenhanced T1-weighted MR images in patients receiving serial doses of gadobutrol, a macrocyclic gadolinium-based contrast agent, with those seen in patients receiving linear gadolinium-based contrast agents. This was a retrospective analysis of on-site patients with brain tumors. Fifty-nine patients received only gadobutrol, and 60 patients received only linear gadolinium-based contrast agents. Linear gadolinium-based contrast agents included gadoversetamide, gadobenate dimeglumine, and gadodiamide. T1 signal intensity in the globus pallidus, dentate nucleus, and pons was measured on the precontrast portions of patients' first and seventh brain MRIs. Ratios of signal intensity comparing the globus pallidus with the pons (globus pallidus/pons) and dentate nucleus with the pons (dentate nucleus/pons) were calculated. Changes in the above signal intensity ratios were compared within the gadobutrol and linear agent groups, as well as between groups. The dentate nucleus/pons signal ratio increased in the linear gadolinium-based contrast agent group ( t = 4.215, P linear gadolinium-based contrast agent group ( t = 2.931, P linear gadolinium-based contrast agents. © 2018 by American Journal of Neuroradiology.

  12. Magnetic resonance imaging of osteosarcoma using a bis(alendronate)-based bone-targeted contrast agent.

    Science.gov (United States)

    Ge, Pingju; Sheng, Fugeng; Jin, Yiguang; Tong, Li; Du, Lina; Zhang, Lei; Tian, Ning; Li, Gongjie

    2016-12-01

    Magnetic resonance (MR) is currently used for diagnosis of osteosarcoma but not well even though contrast agents are administered. Here, we report a novel bone-targeted MR imaging contrast agent, Gd 2 -diethylenetriaminepentaacetate-bis(alendronate) (Gd 2 -DTPA-BA) for the diagnosis of osteosarcoma. It is the conjugate of a bone cell-seeking molecule (i.e., alendronate) and an MR imaging contrast agent (i.e., Gd-DTPA). Its physicochemical parameters were measured, including pK a , complex constant, and T 1 relaxivity. Its bone cell-seeking ability was evaluated by measuring its adsorption on hydroxyapatite. Hemolysis was investigated. MR imaging and biodistribution of Gd 2 -DTPA-BA and Gd-DTPA were studied on healthy and osteosarcoma-bearing nude mice. Gd 2 -DTPA-BA showed high adsorption on hydroxyapatite, the high MR relaxivity (r 1 ) of 7.613mM -1 s -1 (2.6 folds of Gd-DTPA), and no hemolysis. The MR contrast effect of Gd 2 -DTPA-BA was much higher than that of Gd-DTPA after intravenous injection to the mice. More importantly, the MR imaging of osteosarcoma was significantly improved by Gd 2 -DTPA-BA. The signal intensity of Gd 2 -DTPA-BA reached 120.3% at 50min, equal to three folds of Gd-DTPA. The bone targeting index (bone/blood) of Gd 2 -DTPA-BA in the osteosarcoma-bearing mice was very high to 130 at 180min. Furthermore, the contrast enhancement could also be found in the lung due to metastasis of osteosarcoma. Gd 2 -DTPA-BA plays a promising role in the diagnoses of osteosacomas, including the primary bone tumors and metastases. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. Contrast agents for cardiac angiography: effects of a nonionic agent vs. a standard ionic agent

    International Nuclear Information System (INIS)

    Bettmann, M.A.; Bourdillon, P.D.; Barry, W.H.; Brush, K.A.; Levin, D.C.

    1984-01-01

    The effects on cardiac hemodynamics and of a standard contrast agent, sodium methylglucamine diatrizoate [Renografin 76] were compared with the effects of a new nonionic agent (iohexol) in a double-blind study in 51 patietns undergoing coronary angiography and left ventriculography. No significant alteration in measured blood parameters occurred with either contrast agent. Hemodynamic changes occurred with both, but were significantly greater with the standard renografin than with the low-osmolality, nonionic iohexol. After left ventriculography, heart rate increased and peripheral arterial pressure fell with both agents, but less with iohexol. It is concluded that iohexol causes less alteration in cardiac function than does the agent currently most widely used. Nonionic contrast material is likely to improve the safety of coronary angiography, particularly in those patients at greatest risk

  14. Colloidal dispersions of maghemite nanoparticles produced by laser pyrolysis with application as NMR contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Veintemillas-Verdaguer, Sabino [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Morales, Maria del Puerto [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Bomati-Miguel, Oscar [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Bautista, Carmen [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Zhao, Xinqing [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Bonville, Pierre [CEA, CE Saclay, DSM/DRECAM/SPEC, 91191 Gif-Sur-Yvette (France); Alejo, Rigoberto Perez de [Universidad Complutense de Madrid, Unidad de RMN, Paseo Juan XXIII, 1, 28040 Madrid (Spain); Ruiz-Cabello, Jesus [Universidad Complutense de Madrid, Unidad de RMN, Paseo Juan XXIII, 1, 28040 Madrid (Spain); Santos, Martin [Hospital Universitario Puerta de Hierro, Servicio de Cirugia Experimental. C/San Martin de Porres 4, 28035 Madrid (Spain); Tendillo-Cortijo, Francisco J [Hospital Universitario Puerta de Hierro, Servicio de Cirugia Experimental. C/San Martin de Porres 4, 28035 Madrid (Spain); Ferreiros, Joaquin [Hospital Clinico de Madrid ' San Carlos' , Ciudad Universitaria, 28040 Madrid (Spain)

    2004-08-07

    Biocompatible magnetic dispersions have been prepared from {gamma}-Fe{sub 2}O{sub 3} nanoparticles (5 nm) synthesized by continuous laser pyrolysis of Fe(CO){sub 5} vapours. The feasibility of using these dispersions as magnetic resonance imaging (MRI) contrast agents has been analysed in terms of chemical structure, magnetic properties, {sup 1}H NMR relaxation times and biokinetics. The magnetic nanoparticles were dispersed in a strong alkaline solution in the presence of dextran, yielding stable colloids in a single step. The dispersions consist of particle-aggregates 25 nm in diameter measured using transmission electron microscope and a hydrodynamic diameter of 42 nm measured using photon correlation spectroscopy. The magnetic and relaxometric properties of the dispersions were of the same order of magnitude as those of commercial contrast agents produced using coprecipitation. However, these dispersions, when injected intravenously in rats at standard doses showed a mono-exponential blood clearance instead of a biexponential one, with a blood half-life of 7 {+-} 1 min. Furthermore, an important enhancement of the image contrast was observed after the injection, mainly located at the liver and the spleen of the rat. In conclusion, the laser pyrolysis technique seems to be a good alternative to the coprecipitation method for producing MRI contrast agents, with the advantage of being a continuous synthesis method that leads to very uniform particles capable of being dispersed and therefore transformed in a biocompatible magnetic liquid.

  15. Enhanced conjugation stability and blood circulation time of macromolecular gadolinium-DTPA contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Jenjob, Ratchapol [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of); Kun, Na [Department of Biotechnology, The Catholic University of Korea, 43 Jibong-ro, Wonmi-gu, Bucheon-si, Gyeonggi-do 420-743 (Korea, Republic of); Ghee, Jung Yeon [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Shen, Zheyu; Wu, Xiaoxia [Division of Functional Materials and Nano-Devices, Ningbo Institute of Materials Technology & Engineering (NIMTE), Chinese Academy of Sciences, 519 Zhuangshi Street, Zhenhai District, Ningbo, Zhejiang 315201 (China); Cho, Steve K., E-mail: scho@gist.ac.kr [Division of Liberal Arts and Science, GIST College, Gwangju Institute of Science and Technology, Gwangju 500-712 (Korea, Republic of); Lee, Don Haeng [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Department of Internal Medicine, School of Medicine, Inha University Hospital, Incheon 420-751 (Korea, Republic of); Yang, Su-Geun, E-mail: Sugeun.Yang@Inha.ac.kr [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of)

    2016-04-01

    In this study, we prepared macromolecular MR T1 contrast agent: pullulan-conjugated Gd diethylene triamine pentaacetate (Gd-DTPA-Pullulan) and estimated residual free Gd{sup 3+}, chelation stability in competition with metal ions, plasma and tissue pharmacokinetics, and abdominal MR contrast on rats. Residual free Gd{sup 3+} in Gd-DTPA-Pullulan was measured using colorimetric spectroscopy. The transmetalation of Gd{sup 3+} incubated with Ca{sup 2+} was performed by using a dialysis membrane (MWCO 100–500 Da) and investigated by ICP-OES. The plasma concentration profiles of Gd-DTPA-Pullulan were estimated after intravenous injection at a dose 0.1 mmol/kg of Gd. The coronal-plane abdominal images of normal rats were observed by MR imaging. The content of free Gd{sup 3+}, the toxic residual form, was less than 0.01%. Chelation stability of Gd-DTPA-Pullulan was estimated, and only 0.2% and 0.00045% of Gd{sup 3+} were released from Gd-DTPA-Pullulan after 2 h incubation with Ca{sup 2+} and Fe{sup 2+}, respectively. Gd-DTPA-Pullulan displayed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h), much longer than 0.11 h and 0.79 h of Gd-EOB-DTPA. Abdominal MR imaging showed Gd-DTPA-Pullulan maintained initial MR contrast for 30 min. The extended plasma half-life of Gd-DTPA-Pullulan probably allows the prolonged MR acquisition time in clinic with enhanced MR contrast. - Highlights: • Macromolecule (pullulan) conjugated Gd contrast agent (Gd-DTPA-Pullulan) showed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h) in comparison with Gd-EOB-DTPA • Gd-DTPA-pullulan T1 contrast agent exhibited strong chelation stability against Gd. • The extended blood circulation attributed the enhanced and prolonged MR contrast on abdominal region of rats. • The extended blood circulation may provide prolonged MR acquisition time window in clinics.

  16. Low incidence of nephropathy in surgical ICU patients receiving intravenous contrast : a retrospective analysis

    NARCIS (Netherlands)

    Haveman, Jan Willem; Gansevoort, Ron T.; Bongaerts, Alfons H. H.; Nijsten, Maarten W. N.

    Objective: Various studies have documented a markedly high incidence of contrast-induced nephropathy (CIN). Most of these studies were conducted in patients not in the ICU. In ICU patients intravenous contrast may be withheld for fear of CIN. We investigated the incidence of CIN in ICU patients.

  17. Polymeric nanoparticles as OCT contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Al Rawashdeh, Wa' el [RWTH Aachen University, Experimental Molecular Imaging (Germany); Kray, Stefan [RWTH Aachen University, Institute for Semiconductor Electronics (Germany); Pich, Andrij; Pargen, Sascha; Balaceanu, Andreea [RWTH Aachen University, Interactive Material Research (DWI) (Germany); Lenz, Markus; Spoeler, Felix [RWTH Aachen University, Institute for Semiconductor Electronics (Germany); Kiessling, Fabian, E-mail: fkiessling@ukaachen.de; Lederle, Wiltrud [RWTH Aachen University, Experimental Molecular Imaging (Germany)

    2012-12-15

    In this study, the optical properties of two nano-sized polymer colloids in optical coherence tomography (OCT) were compared in vitro with respect to their potential use as contrast agents. We used two types of particles: compact hydrophobic spherical polystyrene (PS) particles and soft water-swollen nanogel (NG) particles both with grafted hydrophilic shell, both prepared at two different sizes (PS at 300 and 150 nm, NG at 300 and 200 nm). The OCT backscattering signals of the particles in a vessel-mimicking highly scattering agar/TiO{sub 2} phantom were compared on either number of particles or weight percent. Larger particles and higher concentrations produced higher OCT contrast. At each concentration tested, a markedly higher contrast was achieved by PS particles than NG particles. PS particles generated a markedly higher OCT contrast than the phantom at concentrations of at least 1 Multiplication-Sign 10{sup 10} or 0.1 % for PS 300 nm and at least 3 Multiplication-Sign 10{sup 11} particles/mL or 0.4 % for PS 150 nm. The contrast generated by NG 300 nm was above the phantom contrast at concentrations of at least 3 Multiplication-Sign 10{sup 11} particles/mL or 1 %, whereas NG 200 nm only at 4 %. At any given weight percent, the differences in OCT contrast between differently sized particles were much less evident than in the comparison based on particle number. PS 300 nm generated also a good contrast ex vivo on chicken muscle tissue. These results strongly suggest that PS spheres have strong potential as intravascular OCT contrast agent, while NG particles need further contrast enhancer for being used as OCT contrast agent.

  18. Contrast enhanced cartilage imaging: Comparison of ionic and non-ionic contrast agents

    International Nuclear Information System (INIS)

    Wiener, Edzard; Woertler, Klaus; Weirich, Gregor; Rummeny, Ernst J.; Settles, Marcus

    2007-01-01

    Our objective was to compare relaxation effects, dynamics and spatial distributions of ionic and non-ionic contrast agents in articular cartilage at concentrations typically used for direct MR arthrography at 1.5 T. Dynamic MR-studies over 11 h were performed in 15 bovine patella specimens. For each of the contrast agents gadopentetate dimeglumine, gadobenate dimeglumine, gadoteridol and mangafodipir trinatrium three patellae were placed in 2.5 mmol/L contrast solution. Simultaneous measurements of T 1 and T 2 were performed every 30 min using a high-spatial-resolution 'MIX'-sequence. T 1 , T 2 and ΔR 1 , ΔR 2 profile plots across cartilage thickness were calculated to demonstrate the spatial and temporal distributions. The charge is one of the main factors which controls the amount of the contrast media diffusing into intact cartilage, but independent of the charge, the spatial distribution across cartilage thickness remains highly inhomogeneous even after 11 h of diffusion. The absolute ΔR 2 -effect in cartilage is at least as large as the ΔR 1 -effect for all contrast agents. Maximum changes were 5-12 s -1 for ΔR 1 and 8-15 s -1 for ΔR 2 . This study indicates that for morphologically intact cartilage only the amount of contrast agents within cartilage is determined by the charge but not the spatial distribution across cartilage thickness. In addition, ΔR 2 can be considered for quantification of contrast agent concentrations, since it is of the same magnitude and less time consuming to measure than ΔR 1

  19. Ultrashort Echo Time Magnetic Resonance Imaging of the Lung Using a High-Relaxivity T1 Blood-Pool Contrast Agent

    Directory of Open Access Journals (Sweden)

    Joris Tchouala Nofiele

    2014-10-01

    Full Text Available The lung remains one of the most challenging organs to image using magnetic resonance imaging (MRI due to intrinsic rapid signal decay. However, unlike conventional modalities such as computed tomography, MRI does not involve radiation and can provide functional and morphologic information on a regional basis. Here we demonstrate proof of concept for a new MRI approach to achieve substantial gains in a signal to noise ratio (SNR in the lung parenchyma: contrast-enhanced ultrashort echo time (UTE imaging following intravenous injection of a high-relaxivity blood-pool manganese porphyrin T1 contrast agent. The new contrast agent increased relative enhancement of the lung parenchyma by over 10-fold compared to gadolinium diethylene triamine pentaacetic acid (Gd-DTPA, and the use of UTE boosted the SNR by a factor of 4 over conventional T1-weighted gradient echo acquisitions. The new agent also maintains steady enhancement over at least 60 minutes, thus providing a long time window for obtaining high-resolution, high-quality images and the ability to measure a number of physiologic parameters.

  20. Field strength and dose dependence of contrast enhancement by gadolinium-based MR contrast agents

    International Nuclear Information System (INIS)

    Rinck, P.A.; Muller, R.N.

    1999-01-01

    The relaxivities r 1 and r 2 of magnetic resonance contrast agents and the T 1 relaxation time values of tissues are strongly field dependent. We present quantitative data and simulations of different gadolinium-based extracellular fluid contrast agents and the modulation of their contrast enhancement by the magnetic field to be able to answer the following questions: How are the dose and field dependences of their contrast enhancement? Is there an interrelationship between dose and field dependence? Should one increase or decrease doses at specific fields? Nuclear magnetic relaxation dispersion data were acquired for the following contrast agents: gadopentetate dimeglumine, gadoterate meglumine, gadodiamide injection, and gadoteridol injection, as well as for several normal and pathological human tissue samples. The magnetic field range stretched from 0.0002 to 4.7 T, including the entire clinical imaging range. The data acquired were then fitted with the appropriate theoretical models. The combination of the diamagnetic relaxation rates (R 1 = 1/T 1 and R 2 = 1/T 2 ) of tissues with the respective paramagnetic contributions of the contrast agents allowed the prediction of image contrast at any magnetic field. The results revealed a nearly identical field and dose-dependent increase of contrast enhancement induced by these contrast agents within a certain dose range. The target tissue concentration (TTC) was an important though nonlinear factor for enhancement. The currently recommended dose of 0.1 mmol/kg body weight seems to be a compromise close to the lower limits of diagnostically sufficient contrast enhancement for clinical imaging at all field strengths. At low field contrast enhancement might be insufficient. Adjustment of dose or concentration, or a new class of contrast agents with optimized relaxivity, would be a valuable contribution to a better diagnostic yield of contrast enhancement at all fields. (orig.)

  1. Intravenous contrast-enhanced cone beam computed tomography (IVCBCT of intrahepatic tumors and vessels

    Directory of Open Access Journals (Sweden)

    Cynthia L. Eccles, BSc

    2016-01-01

    Conclusions: Intravenous-CBCT may enhance the visibility of hepatic vessels and tumor in CBCT scans obtained during breath hold. Optimization of IV contrast timing and reduction of artifacts to improve tumor visualization warrant further investigation.

  2. Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

    International Nuclear Information System (INIS)

    Ogunlade, Olumide; Beard, Paul

    2015-01-01

    Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substance to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type

  3. Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

    Energy Technology Data Exchange (ETDEWEB)

    Ogunlade, Olumide, E-mail: o.ogunlade@ucl.ac.uk; Beard, Paul [Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT (United Kingdom)

    2015-01-15

    Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substance to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type

  4. Superparamagnetic nanoparticle-inclusion microbubbles for ultrasound contrast agents

    International Nuclear Information System (INIS)

    Yang Fang; Li Yixin; Chen Zhongping; Gu Ning; Li Ling; Wu Junru

    2008-01-01

    We have developed a new type of ultrasound (US) contrast agent, consisting of a gas core, a layer of superparamagnetic iron oxide Fe 3 O 4 nanoparticles (SPIO) and an oil in water outermost layer. The newly developed US contrast agent microbubbles have a mean diameter of 760 nm with a polydisperity index (PI) of 0.699. Our in vitro and in vivo experiments have shown that they have the following advantages compared to gas-encapsulated microbbubbles without SPIO inclusion: (1) they provide better contrast for US images; (2) the SPIO-inclusion microbubbles generate a higher backscattering signal; the mean grey scale is 97.9, which is 38.6 higher than that of microbubbles without SPIO; and (3) since SPIO can also serve as a contrast agent of magnetic resonance images (MRI) in vitro, they can be potentially used as contrast agents for double-modality (MRI and US) clinical studies.

  5. The value of paramagnetic contrast agent gadolinium-DTPA in the diagnosis of pituitary adenomas

    International Nuclear Information System (INIS)

    Nakamura, T.; Schoerner, W.; Bittner, R.C.; Felix, R.

    1988-01-01

    The purpose of this study was to assess the role of MR imaging and the paramagnetic contrast agent Gadolinium-DYPA(Gd-DTPA) in the diagnosis of pituitary macroadenomas. 44 macroadenomas were examined with MRI before and after intravenous application of Gd-DTPA. Gd-DTPA produced excellent enhancement of solid adenoma. The best contrast between adenoma and surrounding structures could be gained on post-Gd T1-weighted images. Post-Gd images were equivalent to pre-Gd images in the evaluation of supra- and infrasellar extensions of macroadenomas. Post-Gd images had advantages in the evaluation of cavernous sinus invasion by adenoma. The difference in degree of contrast enhancement between adenoma and cavernous sinus facilitated the exact evaluation of lateral extension by adenoma in 18 cases. Almost equal degree of enhancement of both structures impaired tumor-sinus contrast in 2 cases. In the other 24 cases the tumor filled the cavernous sinus completely. It is our opinion that Gd-DTPA can be used on a widerspread basis because of its excellent capability to highlight and delineate pituitary adenomas. (orig.)

  6. Dual Contrast - Magnetic Resonance Fingerprinting (DC-MRF): A Platform for Simultaneous Quantification of Multiple MRI Contrast Agents.

    Science.gov (United States)

    Anderson, Christian E; Donnola, Shannon B; Jiang, Yun; Batesole, Joshua; Darrah, Rebecca; Drumm, Mitchell L; Brady-Kalnay, Susann M; Steinmetz, Nicole F; Yu, Xin; Griswold, Mark A; Flask, Chris A

    2017-08-16

    Injectable Magnetic Resonance Imaging (MRI) contrast agents have been widely used to provide critical assessments of disease for both clinical and basic science imaging research studies. The scope of available MRI contrast agents has expanded over the years with the emergence of molecular imaging contrast agents specifically targeted to biological markers. Unfortunately, synergistic application of more than a single molecular contrast agent has been limited by MRI's ability to only dynamically measure a single agent at a time. In this study, a new Dual Contrast - Magnetic Resonance Fingerprinting (DC - MRF) methodology is described that can detect and independently quantify the local concentration of multiple MRI contrast agents following simultaneous administration. This "multi-color" MRI methodology provides the opportunity to monitor multiple molecular species simultaneously and provides a practical, quantitative imaging framework for the eventual clinical translation of molecular imaging contrast agents.

  7. Nanoparticle Contrast Agents for Computed Tomography: A Focus on Micelles

    Science.gov (United States)

    Cormode, David P.; Naha, Pratap C.; Fayad, Zahi A.

    2014-01-01

    Computed tomography (CT) is an X-ray based whole body imaging technique that is widely used in medicine. Clinically approved contrast agents for CT are iodinated small molecules or barium suspensions. Over the past seven years there has been a great increase in the development of nanoparticles as CT contrast agents. Nanoparticles have several advantages over small molecule CT contrast agents, such as long blood-pool residence times, and the potential for cell tracking and targeted imaging applications. Furthermore, there is a need for novel CT contrast agents, due to the growing population of renally impaired patients and patients hypersensitive to iodinated contrast. Micelles and lipoproteins, a micelle-related class of nanoparticle, have notably been adapted as CT contrast agents. In this review we discuss the principles of CT image formation and the generation of CT contrast. We discuss the progress in developing non-targeted, targeted and cell tracking nanoparticle CT contrast agents. We feature agents based on micelles and used in conjunction with spectral CT. The large contrast agent doses needed will necessitate careful toxicology studies prior to clinical translation. However, the field has seen tremendous advances in the past decade and we expect many more advances to come in the next decade. PMID:24470293

  8. Intravenous contrast medium application in elderly patients - evaluation of Iopentol (Imagopaque trademark 300)

    International Nuclear Information System (INIS)

    Rathsmann, P.; Jacobs, G.F.; Mueller, R.D.

    2004-01-01

    Purpose: We examined the subjective compatibility of elderly patients who received the intravenous contrast medium Iopentol (Imagopaque trademark 300). In addition, objective data were acquired to show possible interactions between contrast media and organ systems in old patients. Methods and materials: A CT scan with intravenous application of contrast media was performed on 132 patients ranging in age from 75 to 96 years. The patients were questioned about their individual sensations. In addition, blood pressure, creatinine and CT-densitometry were acquired as objective date. Results: The patients' individual sensations and clinical data show a very low rate of complications. Mild allergic reactions were noticed in two patients. No severe anaphylactic reactions were encountered. Statistically significant changes in blood pressure before and after administration of the contrast medium were not observed. The serum creatinine concentration was unchanged after application of contrast media. For CT-densitometry, the patients were divided into two groups, one group with patients 75-84 years and the other group with patients 85-96 years of age. CT-densitometry showed no age-related differences. The protocol of contrast administration resulted in excellent opacification of the examined regions, only the liver did not enhance in some cases before the opacification of the portal vein. Conclusion: It is shown that old age alone is no reason to withhold contrast media containing iodine when performing CT. For the evaluation of the liver, however, the peculiarities of old age have to be taken into account and the interval between injection of the contrast medium and beginning of the spiral-CT has to be extended. (orig.)

  9. Evaluation of oral abdominal contrast agent containing ferric ammonium citrate

    International Nuclear Information System (INIS)

    Shiga, Toshiko; Kawamura, Yasutaka; Iwasaki, Toshiko

    1991-01-01

    We evaluated the effectiveness of oral MRI contrast agent containing ferric ammonium citrate. Twenty patients were arbitrarily divided into 2 groups according to the given dose of 100 and 200 mg Fe of oral MRI contrast agent. MRI was performed before and immediately after ingesting 300 ml solution of oral MRI contrast agent using a 1.5 T superconducting system (GE: Signa). Each dose of 100 and 200 mg Fe of oral MRI contrast agent produced sufficient enhancement of gastrointestinal tract, enough to make clear the pancreatic contour and porta hepatis. There was no significant change in blood and urine analysis observed after taking oral MRI contrast agent. The use of ferric ammonium citrate as an oral MRI contrast agent seems to add valuable information in performing upper abdominal MRI imaging. (author)

  10. A Complete Resolution of Sialadenitis Induced by Iodine Containing Contrast with Intravenous Dexamethasone Infusion

    Directory of Open Access Journals (Sweden)

    Homam Alkaied

    2012-01-01

    Full Text Available Salivary gland enlargement following the administration of iodine is an extremely rare event, and the pathophysiology of iodine-induced sialadenitis is not yet fully known. The onset of symptoms can start within a few minutes to five days after contrast administration. The course of iodine-induced sialadenitis is extremely benign, and rapid resolution of symptoms is expected without treatment. We report the case of a 59-year-old white female who noted mildly painful swelling involving the right side of her face within five days of receiving intravenous iodine-containing contrast. A diagnosis of iodine-related sialadenitis was made. She was given 20 mg of decadron intravenously, with prompt resolution of the swelling within a few hours.

  11. Contrast material-enhanced CT of the abdomen

    International Nuclear Information System (INIS)

    Fishman, E.K.; Kuhlman, J.E.; Garrity, M.; Paris, D.A.

    1988-01-01

    A randomized double-blind comparison of a nonionic contrast agent (Omnipaque) and an ionic contrast agent (Hypaque) was performed to determine any difference between the two agents in the quality and performance of computed body tomography (CT). A total of 40 patient studies were performed on a state-of-the-art CT scanner with similar scanning techniques. The contrast agent was administered intravenously as a rapid infusion in all cases. The image quality of the abdominal CT scans was good to excellent in all cases. There was no difference between the ionic and nonionic agents in terms of study quality. The 20 patients who received nonionic contrast agents had no major or minor reactions. Five of the 20 patients receiving the ionic contrast agent had a total of ten adverse reactions, including nausea and vomiting, nasal congestion, sneezing, and urticaria. The authors conclude that nonionic contrast agents provide high-quality CT scans equal to those provided by ionic agents and also result in fewer reactions and less discomfort

  12. Safety of MR liver specific contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Bellin, Marie-France [Hopital Paul Brousse, Universite Paris 11, Villejuif Cedex (France); Webb, Judith A.W. [St. Bartholomew' s Hospital, Department of Diagnostic Imaging, London (United Kingdom); Molen, Aart J. van der [Leiden University Medical Centre, Department of Radiology, Leiden (Netherlands); Thomsen, Henrik S. [Copenhagen University Hospital at Herlev, Department of Diagnostic Radiology 54E2, Herlev (Denmark); Morcos, Sameh K. [Northern General Hospital, Sheffield Teaching Hospitals NHS Trust, Department of Diagnostic Imaging, Sheffield (United Kingdom)

    2005-08-01

    Over the past few years a number of magnetic resonance (MR) liver specific contrast agents have been introduced. In this report the safety issues of these agents are addressed. A literature search was carried out. Based on the available information, simple guidelines on the safety issue of liver specific contrast agents have been produced by the Contrast Media Safety Committee of the European Society of Urogenital Radiology. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela. Liver specific contrast agents appear in general to be safe and well tolerated. However, the incidence of adverse reactions with iron oxides and the intravenous manganese based agent seems to be slightly higher than with gadolinium based agents. However, no safety information from comparative clinical trials has been published. Guidelines on the safety aspects are presented. (orig.)

  13. Safety of MR liver specific contrast media

    International Nuclear Information System (INIS)

    Bellin, Marie-France; Webb, Judith A.W.; Molen, Aart J. van der; Thomsen, Henrik S.; Morcos, Sameh K.

    2005-01-01

    Over the past few years a number of magnetic resonance (MR) liver specific contrast agents have been introduced. In this report the safety issues of these agents are addressed. A literature search was carried out. Based on the available information, simple guidelines on the safety issue of liver specific contrast agents have been produced by the Contrast Media Safety Committee of the European Society of Urogenital Radiology. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela. Liver specific contrast agents appear in general to be safe and well tolerated. However, the incidence of adverse reactions with iron oxides and the intravenous manganese based agent seems to be slightly higher than with gadolinium based agents. However, no safety information from comparative clinical trials has been published. Guidelines on the safety aspects are presented. (orig.)

  14. Contrast-enhanced harmonic endoscopic ultrasound

    DEFF Research Database (Denmark)

    Săftoiu, A; Dietrich, C F; Vilmann, P

    2012-01-01

    Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, and improving staging and guidance of therapeutic procedures. Although...... initially used as Doppler signal enhancers, second-generation microbubble contrast agents are now used with specific contrast harmonic imaging techniques, which benefit from the highly nonlinear behavior of the microbubbles. Contrast-specific modes based on multi-pulse technology are used to perform...... contrast-enhanced harmonic EUS based on a very low mechanical index (0.08 - 0.12). Quantification techniques based on dynamic contrast-enhanced ultrasound have been recommended for perfusion imaging and monitoring of anti-angiogenic treatment, mainly based on time-intensity curve analysis. Most...

  15. Gadolinium-based contrast agents in pediatric magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gale, Eric M.; Caravan, Peter [Massachusetts General Hospital, Harvard Medical School, Department of Radiology, The Martinos Center for Biomedical Imaging, Boston, MA (United States); Rao, Anil G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); McDonald, Robert J. [College of Medicine, Mayo Clinic, Department of Radiology, Rochester, MN (United States); Winfeld, Matthew [University of Pennsylvania Perelman School of Medicine, Philadelphia, PA (United States); Fleck, Robert J. [Cincinnati Children' s Hospital Medical Center, Department of Pediatric Radiology, Cincinnati, OH (United States); Gee, Michael S. [MassGeneral Hospital for Children, Harvard Medical School, Division of Pediatric Imaging, Department of Radiology, Boston, MA (United States)

    2017-05-15

    Gadolinium-based contrast agents can increase the accuracy and expediency of an MRI examination. However the benefits of a contrast-enhanced scan must be carefully weighed against the well-documented risks associated with administration of exogenous contrast media. The purpose of this review is to discuss commercially available gadolinium-based contrast agents (GBCAs) in the context of pediatric radiology. We discuss the chemistry, regulatory status, safety and clinical applications, with particular emphasis on imaging of the blood vessels, heart, hepatobiliary tree and central nervous system. We also discuss non-GBCA MRI contrast agents that are less frequently used or not commercially available. (orig.)

  16. High-field, high-resolution, susceptibility-weighted magnetic resonance imaging: improved image quality by addition of contrast agent and higher field strength in patients with brain tumors

    International Nuclear Information System (INIS)

    Pinker, K.; Noebauer-Huhmann, I.M.; Szomolanyi, P.; Weber, M.; Grabner, G.; Trattnig, S.; Stavrou, I.; Knosp, E.; Hoeftberger, R.; Stadlbauer, A.

    2008-01-01

    To demonstrate intratumoral susceptibility effects in malignant brain tumors and to assess visualization of susceptibility effects before and after administration of the paramagnetic contrast agent MultiHance (gadobenate dimeglumine; Bracco Imaging), an agent known to have high relaxivity, with respect to susceptibility effects, image quality, and reduction of scan time. Included in the study were 19 patients with malignant brain tumors who underwent high-resolution, susceptibility-weighted (SW) MR imaging at 3 T before and after administration of contrast agent. In all patients, Multihance was administered intravenously as a bolus (0.1 mmol/kg body weight). MR images were individually evaluated by two radiologists with previous experience in the evaluation of pre- and postcontrast 3-T SW MR images with respect to susceptibility effects, image quality, and reduction of scan time. In the 19 patients 21 tumors were diagnosed, of which 18 demonstrated intralesional susceptibility effects both in pre- and postcontrast SW images, and 19 demonstrated contrast enhancement in both SW images and T1-weighted spin-echo MR images. Conspicuity of susceptibility effects and image quality were improved in postcontrast images compared with precontrast images and the scan time was also reduced due to decreased TE values from 9 min (precontrast) to 7 min (postcontrast). The intravenous administration of MultiHance, an agent with high relaxivity, allowed a reduction of scan time from 9 min to 7 min while preserving excellent susceptibility effects and image quality in SW images obtained at 3 T. Contrast enhancement and intralesional susceptibility effects can be assessed in one sequence. (orig.)

  17. Gd-HOPO Based High Relaxivity MRI Contrast Agents

    Energy Technology Data Exchange (ETDEWEB)

    Datta, Ankona; Raymond, Kenneth

    2008-11-06

    Tris-bidentate HOPO-based ligands developed in our laboratory were designed to complement the coordination preferences of Gd{sup 3+}, especially its oxophilicity. The HOPO ligands provide a hexadentate coordination environment for Gd{sup 3+} in which all he donor atoms are oxygen. Because Gd{sup 3+} favors eight or nine coordination, this design provides two to three open sites for inner-sphere water molecules. These water molecules rapidly exchange with bulk solution, hence affecting the relaxation rates of bulk water olecules. The parameters affecting the efficiency of these contrast agents have been tuned to improve contrast while still maintaining a high thermodynamic stability for Gd{sup 3+} binding. The Gd- HOPO-based contrast agents surpass current commercially available agents ecause of a higher number of inner-sphere water molecules, rapid exchange of inner-sphere water molecules via an associative mechanism, and a long electronic relaxation time. The contrast enhancement provided by these agents is at least twice that of commercial contrast gents, which are based on polyaminocarboxylate ligands.

  18. Gd-DTPA L-cystine bisamide copolymers as novel biodegradable macromolecular contrast agents for MR blood pool imaging.

    Science.gov (United States)

    Kaneshiro, Todd L; Ke, Tianyi; Jeong, Eun-Kee; Parker, Dennis L; Lu, Zheng-Rong

    2006-06-01

    The purpose of this study was to synthesize biodegradable Gd-DTPA L-cystine bisamide copolymers (GCAC) as safe and effective, macromolecular contrast agents for magnetic resonance imaging (MRI) and to evaluate their biodegradability and efficacy in MR blood pool imaging in an animal model. Three new biodegradable GCAC with different substituents at the cystine bisamide [R = H (GCAC), CH2CH2CH3 (Gd-DTPA L-cystine bispropyl amide copolymers, GCPC), and CH(CH3)2 (Gd-DTPA cystine bisisopropyl copolymers, GCIC)] were prepared by the condensation copolymerization of diethylenetriamine pentaacetic acid (DTPA) dianhydride with cystine bisamide or bisalkyl amides, followed by complexation with gadolinium triacetate. The degradability of the agents was studied in vitro by incubation in 15 microM cysteine and in vivo with Sprague-Dawley rats. The kinetics of in vivo contrast enhancement was investigated in Sprague-Dawley rats on a Siemens Trio 3 T scanner. The apparent molecular weight of the polydisulfide Gd(III) chelates ranged from 22 to 25 kDa. The longitudinal (T1) relaxivities of GCAC, GCPC, and GCIC were 4.37, 5.28, and 5.56 mM(-1) s(-1) at 3 T, respectively. The polymeric ligands and polymeric Gd(III) chelates readily degraded into smaller molecules in incubation with 15 microM cysteine via disulfide-thiol exchange reactions. The in vitro degradation rates of both the polymeric ligands and macromolecular Gd(III) chelates decreased as the steric effect around the disulfide bonds increased. The agents readily degraded in vivo, and the catabolic degradation products were detected in rat urine samples collected after intravenous injection. The agents showed strong contrast enhancement in the blood pool, major organs, and tissues at a dose of 0.1 mmol Gd/kg. The difference of their in vitro degradability did not significantly alter the kinetics of in vivo contrast enhancement of the agents. These novel GCAC are promising contrast agents for cardiovascular and tumor MRI

  19. Magnetic Resonance Imaging Contrast Agents: A Review of Literature

    Directory of Open Access Journals (Sweden)

    Zahra Sahraei

    2015-10-01

    Full Text Available  Magnetic Resonance Imaging (MRI contrast agents most commonly agents used in diagnosing different diseases. Several agents have been ever introduced with different peculiar characteristics. They vary in potency, adverse reaction and other specification, so it is important to select the proper agent in different situations. We conducted a systematic literature search in MEDLINE/PUBMED, Web of Science (ISI, Scopus,Google Scholar by using keywords "gadolinium" and "MRI contrast Medias", "Gadofosvest", "Gadobenate" and "Gadoxetate". The most frequent contrast media agents made based on gadolinium (Gd. These are divided into two categories based on the structure of their chelating parts, linear agents and macrocyclic agents. All characteristics of contrast media factors, including efficiency, kinetic properties, stability, side effects and the rate of resolution are directly related to the structure of chelating part of that formulation.In vitro data has shown that the macrocyclic compounds are the most stable Gd-CA as they do not bind to serum proteins, they all possess similar and relatively low relaxivity and the prevalence of Nephrogenic Systemic Fibrosis (NSF has decreased by increasing the use of macrocyclic agents in recent years. No cases of NSF have been recorded after the administration of any of the high-relaxivity protein interacting agents, the vascular imaging agent gadofosveset trisodium (Ablavar, the hepatic imaging agent gadoxetate meglumine (Eovist, and the multipurpose agent gadobenate dimeglumine (MultiHance. In pregnancy and lactating women, stable macrocyclic agent is recommended.

  20. Effects of contrast agents on the fallopian tube in a rabbit model

    International Nuclear Information System (INIS)

    Moore, D.E.

    1989-01-01

    Selection of the optimal contrast agent for hysterosalpingography was the focus of this study. The authors have evaluated the effect of different iodinated contrast agents on the fallopian tube of a rabbit. Ethiodol (oil-soluble contrast agent), methylglucamine iothalomate (water-soluble ionic agent) 30% and 60%, and Ioxilan (water-soluble monionic contrast agent) were compared. The agents were introduced by fallopian tube catheterization. Findings suggested that nonionic water-soluble contrast agents were the least detrimental to the fallopian tube and surrounding tissue. Iothalomate 60% resulted in mild inflammatory changes. Oil-soluble contrast agents caused granulomatous reaction and fibrinous adhesions

  1. Cellulose nanoparticles: photoacoustic contrast agents that biodegrade to simple sugars

    Science.gov (United States)

    Jokerst, Jesse V.; Bohndiek, Sarah E.; Gambhir, Sanjiv S.

    2014-03-01

    In photoacoustic imaging, nanoparticle contrast agents offer strong signal intensity and long-term stability, but are limited by poor biodistribution and clearance profiles. Conversely, small molecules offer renal clearance, but relatively low photoacoustic signal. Here we describe a cellulose-based nanoparticle with photoacoustic signal superior to gold nanorods, but that undergoes enzymatic cleavage into constituent glucose molecules for renal clearance. Cellulose nanoparticles (CNPs) were synthesized through acidic cleavage of cellulose linters and purified with centrifugation. TEM indicated that the nanoparticles were 132 +/- 46 nm; the polydispersity index was 0.138. Ex vivo characterization showed a photoacoustic limit of detection of 0.02 mg/mL CNPs, and the photoacoustic signal of CNPs was 1.5- to 3.0-fold higher than gold nanorods (also at 700 nm resonance) on a particle-to-particle basis. Cell toxicity assays suggested that overnight doses below 0.31 mg/mL CNPs produced no significant (p>0.05) impact on cell metabolism. Intravenous doses up to 0.24 mg were tolerated well in nude mice. Subcutaneous and orthotopic tumor xenografts of the OV2008 ovarian cancer cell line were then created in nude mice. Data was collected with a Nexus128 scanner from Endra LifeSciences. Spectral data used a LAZR system from Visualsonics both at 700 nm excitation. We injected CNPs (0.024 mg, 0.048 mg, and 0.80 mg) via tail vein and showed that the tumor photoacoustic signal reached maximum increase between 10 and 20 minutes. All injected concentrations were statistically (p0.96 suggesting quantitative signal. CNP biodegradation was demonstrated ex vivo with a glucose assay. CNPs in the presence of cellulase were reduced to free glucose in under than four hours. The glucose concentration before addition of cellulase was not detectable, but increased to 92.1 μg/mL in four hours. CNPs in the absence of cellulase did not produce glucose. Small fragments of nanoparticle in the

  2. Ultrasmall cationic superparamagnetic iron oxide nanoparticles as nontoxic and efficient MRI contrast agent and magnetic-targeting tool

    Science.gov (United States)

    Uchiyama, Mayara Klimuk; Toma, Sergio Hiroshi; Rodrigues, Stephen Fernandes; Shimada, Ana Lucia Borges; Loiola, Rodrigo Azevedo; Cervantes Rodríguez, Hernán Joel; Oliveira, Pedro Vitoriano; Luz, Maciel Santos; Rabbani, Said Rahnamaye; Toma, Henrique Eisi; Poliselli Farsky, Sandra Helena; Araki, Koiti

    2015-01-01

    Fully dispersible, cationic ultrasmall (7 nm diameter) superparamagnetic iron oxide nanoparticles, exhibiting high relaxivity (178 mM−1s−1 in 0.47 T) and no acute or subchronic toxicity in Wistar rats, were studied and their suitability as contrast agents for magnetic resonance imaging and material for development of new diagnostic and treatment tools demonstrated. After intravenous injection (10 mg/kg body weight), they circulated throughout the vascular system causing no microhemorrhage or thrombus, neither inflammatory processes at the mesentery vascular bed and hepatic sinusoids (leukocyte rolling, adhesion, or migration as evaluated by intravital microscopy), but having been spontaneously concentrated in the liver, spleen, and kidneys, they caused strong negative contrast. The nanoparticles are cleared from kidneys and bladder in few days, whereas the complete elimination from liver and spleen occurred only after 4 weeks. Ex vivo studies demonstrated that cationic ultrasmall superparamagnetic iron oxide nanoparticles caused no effects on hepatic and renal enzymes dosage as well as on leukocyte count. In addition, they were readily concentrated in rat thigh by a magnet showing its potential as magnetically targeted carriers of therapeutic and diagnostic agents. Summarizing, cationic ultrasmall superparamagnetic iron oxide nanoparticles are nontoxic and efficient magnetic resonance imaging contrast agents useful as platform for the development of new materials for application in theranostics. PMID:26251595

  3. The possible role of intravenous lipid emulsion in the treatment of chemical warfare agent poisoning

    Directory of Open Access Journals (Sweden)

    Arik Eisenkraft

    Full Text Available Organophosphates (OPs are cholinesterase inhibitors that lead to a characteristic toxidrome of hypersecretion, miosis, dyspnea, respiratory insufficiency, convulsions and, without proper and early antidotal treatment, death. Most of these compounds are highly lipophilic. Sulfur mustard is a toxic lipophilic alkylating agent, exerting its damage through alkylation of cellular macromolecules (e.g., DNA, proteins and intense activation of pro-inflammatory pathways. Currently approved antidotes against OPs include the peripheral anticholinergic drug atropine and an oxime that reactivates the inhibited cholinesterase. Benzodiazepines are used to stop organophosphate-induced seizures. Despite these approved drugs, efforts have been made to introduce other medical countermeasures in order to attenuate both the short-term and long-term clinical effects following exposure. Currently, there is no antidote against sulfur mustard poisoning. Intravenous lipid emulsions are used as a source of calories in parenteral nutrition. In recent years, efficacy of lipid emulsions has been shown in the treatment of poisoning by fat-soluble compounds in animal models as well as clinically in humans. In this review we discuss the usefulness of intravenous lipid emulsions as an adjunct to the in-hospital treatment of chemical warfare agent poisoning. Keywords: Intravenous lipid emulsion, Organophosphates, Sulfur mustard, Antidotes, Poisoning, Chemical Warfare agents

  4. Orotracheal administration of contrast agents: a new protocol for brain tumor targeting.

    Science.gov (United States)

    Bianchi, Andrea; Moncelet, Damien; Lux, François; Plissonneau, Marie; Rizzitelli, Silvia; Ribot, Emeline Julie; Tassali, Nawal; Bouchaud, Véronique; Tillement, Olivier; Voisin, Pierre; Crémillieux, Yannick

    2015-06-01

    The development of new non-invasive diagnostic and therapeutic approaches is of paramount importance in order to improve the outcome of patients with glioblastoma (GBM). In this work we investigated a completely non-invasive pre-clinical protocol to effectively target and detect brain tumors through the orotracheal route, using ultra-small nanoparticles (USRPs) and MRI. A mouse model of GBM was developed. In vivo MRI acquisitions were performed before and after intravenous or orotracheal administration of the nanoparticles to identify and segment the tumor. The accumulation of the nanoparticles in neoplastic lesions was assessed ex vivo through fluorescence microscopy. Before the administration of contrast agents, MR images allowed the identification of the presence of abnormal brain tissue in 73% of animals. After orotracheal or intravenous administration of USRPs, in all the mice an excellent co-localization of the position of the tumor with MRI and histology was observed. The elimination time of the USRPs from the tumor after the orotracheal administration was approximately 70% longer compared with intravenous injection. MRI and USRPs were shown to be powerful imaging tools able to detect, quantify and longitudinally monitor the development of GBMs. The absence of ionizing radiation and high resolution of MRI, along with the complete non-invasiveness and good reproducibility of the proposed protocol, make this technique potentially translatable to humans. To our knowledge, this is the first time that the advantages of a needle-free orotracheal administration route have been demonstrated for the investigation of the pathomorphological changes due to GBMs. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Saving radiation dose and contrast media in intravenous digital subtraction angiography by use of bolus chasing

    International Nuclear Information System (INIS)

    Rueckforth, J.; Schuermann, K.; Vorwerk, D.; Guenther, R.W.

    1998-01-01

    Purpose: This study evaluates the dose area product, the amount of contrast media and the examination quality of the bolus chasing technique compared to the single-step technique in intravenous digital subtraction angiography. Material and Methods: 15 examinations each with bolus chasing and single-step technique were compared. The dose area product and the volume of contrast media were recorded. The examination quality was scored by two examiners. Results: With bolus chasing the volume of the administered contrast media could be decreased on average by 114 ml (43%). The difference between the dose area product of bolus chasing (722 dGy/cm 2 ) and single-step technique (1910 dGy/cm 2 ) was significant. No significant difference in examination quality was found. Conclusions: The intravenous bolus chasing technique is a practicable method. Compared to the single-step technique it allows a remarkable dose reduction and a low consumption of contrast media without restriction of examination quality. (orig.) [de

  6. Influence of radiographic contrast agents on quantitative coronary angiography

    International Nuclear Information System (INIS)

    Jost, Stefan; Hausmann, Dirk; Lippolt, Peter; Gerhardt, Uwe; Lichtlen, Paul R.

    1997-01-01

    Purpose. Quantitative angiographic studies on the vasomotility of epicardial coronary arteries are gaining increasing relevance. We investigated whether radiographic contrast agents might influence coronary vasomotor tone and thereby the results of such studies. Methods. Coronary angiograms were taken in 12 patients with coronary artery disease at intervals of 5, 3, 2, and 1 min with the low-osmolar, nonionic contrast agent iopamidol 300, and were repeated at identical intervals with the high-osmolar, ionic agent diatrizoate 76%. Results. Quantitative cine film analysis demonstrated no significant diameter changes in angiographically normal and stenotic coronary arteries with iopamidol. With diatrizoate, however, normal segments were dilated 2%±2% (p<0.01) after 2 min and 10%±3% after the 1 min interval (p<0.001). Stenoses showed no uniform responses to diatrizoate. Conclusion. Low-osmolar, nonionic contrast agents should be preferred for quantitative angiographic studies on epicardial coronary vasomotility. When using ionic contrast agents, injection intervals of at least 3 min are required

  7. Cationic Contrast Agent Diffusion Differs Between Cartilage and Meniscus.

    Science.gov (United States)

    Honkanen, Juuso T J; Turunen, Mikael J; Freedman, Jonathan D; Saarakkala, Simo; Grinstaff, Mark W; Ylärinne, Janne H; Jurvelin, Jukka S; Töyräs, Juha

    2016-10-01

    Contrast enhanced computed tomography (CECT) is a non-destructive imaging technique used for the assessment of composition and structure of articular cartilage and meniscus. Due to structural and compositional differences between these tissues, diffusion and distribution of contrast agents may differ in cartilage and meniscus. The aim of this study is to determine the diffusion kinematics of a novel iodine based cationic contrast agent (CA(2+)) in cartilage and meniscus. Cylindrical cartilage and meniscus samples (d = 6 mm, h ≈ 2 mm) were harvested from healthy bovine knee joints (n = 10), immersed in isotonic cationic contrast agent (20 mgI/mL), and imaged using a micro-CT scanner at 26 time points up to 48 h. Subsequently, normalized X-ray attenuation and contrast agent diffusion flux, as well as water, collagen and proteoglycan (PG) contents in the tissues were determined. The contrast agent distributions within cartilage and meniscus were different. In addition, the normalized attenuation and diffusion flux were higher (p < 0.05) in cartilage. Based on these results, diffusion kinematics vary between cartilage and meniscus. These tissue specific variations can affect the interpretation of CECT images and should be considered when cartilage and meniscus are assessed simultaneously.

  8. Contrasts agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bonnet, P.A.; Fernandez, J.P.; Milhavet, J.C.; Chapat, J.P.; Almes, C.; Bruel, J.M.; Rouanet, J.P.; Lamarque, J.L.

    1984-01-01

    Changing different parameters involved in imaging procedures, paramagnetic substances provide contrast enhancement in MRI. Contrast agents presently studied in animals and clinical trials, are either salts or complexes of mineral ions either nitroxide stable free radicals. Their development should extend the possibilities of tissular characterization and fonctional or metabolic evaluation of the MRI [fr

  9. Renal Safety of Iodinated Contrast Media Depending on Their Osmolarity – Current Outlooks

    International Nuclear Information System (INIS)

    Mruk, Bartosz

    2016-01-01

    Iodinated contrast media (ICM) are commonly administered pharmaceutical agents. Most often they are used intravenously and intraarterially. Although iodinated contrast agents are relatively safe and widely used, adverse events occur and questions remain about their use, safety, and interactions. The most important adverse effects of contrast media include hypersensitivity reactions, thyroid dysfunction, and contrast-induced nephropathy. Radiologists must be aware of the risk factors for reactions to contrast media. Nonionic iodinated contrast agents can be divided into monomeric, low-osmolar, and dimeric, iso-osmolar classes. The osmotic characteristics of contrast media have been a significant focus in many investigations of contrast-induced nephropathy

  10. Low-Molecular-Weight Iron Chelates May Be an Alternative to Gadolinium-based Contrast Agents for T1-weighted Contrast-enhanced MR Imaging.

    Science.gov (United States)

    Boehm-Sturm, Philipp; Haeckel, Akvile; Hauptmann, Ralf; Mueller, Susanne; Kuhl, Christiane K; Schellenberger, Eyk A

    2018-02-01

    Purpose To synthesize two low-molecular-weight iron chelates and compare their T1 contrast effects with those of a commercial gadolinium-based contrast agent for their applicability in dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging. Materials and Methods The animal experiments were approved by the local ethics committee. Two previously described iron (Fe) chelates of pentetic acid (Fe-DTPA) and of trans-cyclohexane diamine tetraacetic acid (Fe-tCDTA) were synthesized with stability constants several orders of magnitude higher than those of gadolinium-based contrast agents. The T1 contrast effects of the two chelates were compared with those of gadopentetate dimeglumine in blood serum phantoms at 1.5 T, 3 T, and 7 T. For in vivo studies, a human breast cancer cell line (MDA-231) was implanted in five mice per group. The dynamic contrast effects of the chelates were compared by performing DCE MR imaging with intravenous application of Fe-DTPA or Fe-tCDTA on day 1 and DCE MR imaging in the same tumors with gadopentetate dimeglumine on day 2. Quantitative DCE maps were generated with software and were compared by means of a one-tailed Pearson correlation test. Results Relaxivities in serum (0.94 T at room temperature) of Fe-tCDTA (r1 = 2.2 mmol -1 · sec -1 , r2 = 2.5 mmol -1 · sec -1 ) and Fe-DTPA (r1 = 0.9 mmol -1 · sec -1 , r2 = 0.9 mmol -1 · sec -1 ) were approximately twofold and fivefold lower, respectively, compared with those of gadopentetate dimeglumine (r1 = 4.1 mmol -1 · sec -1 , r2 = 4.8 mmol -1 · sec -1 ). Used at moderately higher concentrations, however, iron chelates generated similar contrast effects at T1-weighted MR imaging in vitro in serum, in vivo in blood, and for DCE MR imaging of breast cancer xenografts. The volume transfer constant values for Fe-DTPA and Fe-tCDTA in the same tumors correlated well with those observed for gadopentetate dimeglumine (Fe-tCDTA Pearson R, 0.99; P = .0003; Fe-DTPA Pearson R, 0.97; P

  11. The use of contrast agents in cardiac MRI

    International Nuclear Information System (INIS)

    Maurer, A.H.; Osbakken, M.

    1988-01-01

    Inherent NMR phenomena such as T/sub 1/ and T/sub 2/, and proton density can be used to provide tissue contrast on MR images. However, there are times when this contrast is not sufficient or does not provide tissue characterization data sufficient for use in definition of a pathophysiological insult. In this later case, paramagnetic agents might be of use in enhancement of relaxation time differences in one tissue or one portion of a tissue compared to another. Although several agents have been evaluated in this regard, most have been found inadequate because of their tissue toxicity. At present, gadolinium diethylenetriamine pentaacetric acid (Gd-DTPA) (which is an agent used in nuclear medicine studies) appears to be a good agent to use to distinguish normal from ischemic tissue. This agent has been used by a number of investigators to evaluate myocardial ischemia and provides images with better sensitivity and specificity for ischemia than imaging techniques using natural tissue contrast based on T/sub 1/ and T/sub 2/ differences

  12. Correlation of contrast agent kinetics between iodinated contrast-enhanced spectral tomosynthesis and gadolinium-enhanced MRI of breast lesions

    International Nuclear Information System (INIS)

    Froeling, Vera; Diekmann, Felix; Renz, Diane M.; Fallenberg, Eva M.; Steffen, Ingo G.; Diekmann, Susanne; Schmitzberger, Florian F.; Lawaczeck, Ruediger

    2013-01-01

    Assessment of contrast agent kinetics in contrast-enhanced MRI (CE-MRI) with gadolinium-containing contrast agents offers the opportunity to predict breast lesion malignancy. The goal of our study was to determine if similar patterns exist for spectral contrast-enhanced digital breast tomosynthesis (CE-DBT) using an iodinated contrast agent. The protocol of our prospective study was approved by the relevant institutional review board and the German Federal Office for Radiation Protection. All patients provided written informed consent. We included 21 women with a mean age of 62.4 years. All underwent ultrasound-guided biopsy of a suspect breast lesion, spectral CE-DBT and CE-MRI. For every breast lesion, contrast agent kinetics was assessed by signal intensity-time curves for spectral CE-DBT and CE-MRI. Statistical comparison used Cohen's kappa and Spearman's rho test. Spearman's rho of 0.49 showed significant (P = 0.036) correlation regarding the contrast agent kinetics in signal intensity-time curves for spectral CE-DBT and CE-MRI. Cohen's kappa indicated moderate agreement (kappa = 0.438). There is a statistically significant correlation between contrast agent kinetics in the signal intensity-time curves for spectral CE-DBT and CE-MRI. Observing intralesional contrast agent kinetics in spectral CE-DBT may aid evaluation of malignant breast lesions. (orig.)

  13. New strategies to prolong the in vivo life span of iron-based contrast agents for MRI.

    Directory of Open Access Journals (Sweden)

    Antonella Antonelli

    Full Text Available Superparamagnetic iron oxide (SPIO and ultra small superparamagnetic iron oxide (USPIO nanoparticles have been developed as magnetic resonance imaging (MRI contrast agents. Iron oxide nanoparticles, that become superparamagnetic if the core particle diameter is ~ 30 nm or less, present R1 and R2 relaxivities which are much higher than those of conventional paramagnetic gadolinium chelates. Generally, these magnetic particles are coated with biocompatible polymers that prevent the agglomeration of the colloidal suspension and improve their blood distribution profile. In spite of their potential as MRI blood contrast agents, the biomedical application of iron oxide nanoparticles is still limited because of their intravascular half-life of only few hours; such nanoparticles are rapidly cleared from the bloodstream by macrophages of the reticulo-endothelial system (RES. To increase the life span of these MRI contrast agents in the bloodstream we proposed the encapsulation of SPIO nanoparticles in red blood cells (RBCs through the transient opening of cell membrane pores. We have recently reported results obtained by applying our loading procedure to several SPIO nanoparticles with different chemical physical characteristics such as size and coating agent. In the current investigation we showed that the life span of iron-based contrast agents in the mice bloodstream was prolonged to 12 days after the intravenous injection of murine SPIO-loaded RBCs. Furthermore, we developed an animal model that implicates the pretreatment of animals with clodronate to induce a transient suppression of tissue macrophages, followed by the injection of human SPIO-loaded RBCs which make it possible to encapsulate nanoparticle concentrations (5.3-16.7 mM Fe higher than murine SPIO-loaded RBCs (1.4-3.55 mM Fe. The data showed that, when human RBCs are used as more capable SPIO nanoparticle containers combined with a depletion of tissue macrophages, Fe concentration in

  14. CEST and PARACEST MR contrast agents

    International Nuclear Information System (INIS)

    Hancu, Ileana; Dixon, W. Thomas; Woods, Mark; Sherry, A. Dean; Vinogradov, Elena; Lenkinski, Robert E.

    2010-01-01

    In this review we describe the status of development for a new class of magnetic resonance (MR) contrast agents, based on chemical exchange saturation transfer (CEST). The mathematics and physics relevant to the description of the CEST effect in MR are presented in an appendix published in the online version only. We discuss the issues arising when translating in vitro results obtained with CEST agents to using these MR agents in in vivo model studies and in humans. Examples are given on how these agents are imaged in vivo. We summarize the status of development of these CEST agents, and speculate about the next steps that may be taken towards the demonstration of CEST MR imaging in clinical applications

  15. Ultrasound Contrast Agent Microbubble Dynamics

    NARCIS (Netherlands)

    Overvelde, M.L.J.; Vos, Henk; de Jong, N.; Versluis, Michel; Paradossi, Gaio; Pellegretti, Paolo; Trucco, Andrea

    2010-01-01

    Ultrasound contrast agents are traditionally used in ultrasound-assisted organ perfusion imaging. Recently the use of coated microbubbles has been proposed for molecular imaging applications where the bubbles are covered with a layer of targeting ligands to bind specifically to their target cells.

  16. Extracellular gadolinium-based contrast media: An overview

    International Nuclear Information System (INIS)

    Bellin, Marie-France; Van Der Molen, Aart J.

    2008-01-01

    Increasing use is made of extracellular MRI contrast agents that alter the image contrast following intravenous administration; they predominantly shorten the T1 relaxation time of tissues. The degree and location of these changes provide substantial diagnostic information. However gadolinium-based contrast agents (Gd-CA) are not inert drugs. They may cause acute non-renal adverse reactions (e.g. anaphylactoid reactions), acute renal adverse reactions (e.g. contrast induced nephropathy), delayed adverse reactions (nephrogenic systemic fibrosis) and problems at the site of injection (e.g. local necrosis). This review describes the current status of Gd-CA, their mechanism of action, chemical structure, pharmacokinetics, dosage, elimination, nephrotoxicity and adverse events

  17. Extracellular gadolinium-based contrast media: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Bellin, Marie-France [University Paris-Sud 11, Department of Radiology, University Hospital Paul-Brousse, AP-HP, 12, Avenue Paul Vaillant-Couturier, 94804 Villejuif Cedex (France)], E-mail: marie-france.bellin@pbr.aphp.fr; Van Der Molen, Aart J. [University Paris-Sud 11, Department of Radiology, University Hospital Paul-Brousse, AP-HP, 12, Avenue Paul Vaillant-Couturier, 94804 Villejuif Cedex (France)

    2008-05-15

    Increasing use is made of extracellular MRI contrast agents that alter the image contrast following intravenous administration; they predominantly shorten the T1 relaxation time of tissues. The degree and location of these changes provide substantial diagnostic information. However gadolinium-based contrast agents (Gd-CA) are not inert drugs. They may cause acute non-renal adverse reactions (e.g. anaphylactoid reactions), acute renal adverse reactions (e.g. contrast induced nephropathy), delayed adverse reactions (nephrogenic systemic fibrosis) and problems at the site of injection (e.g. local necrosis). This review describes the current status of Gd-CA, their mechanism of action, chemical structure, pharmacokinetics, dosage, elimination, nephrotoxicity and adverse events.

  18. Quality of roentgenological visualization and tolerance of various intravenous cholegraphic contrast media

    International Nuclear Information System (INIS)

    Tischendorf, P.

    1980-01-01

    The recently introduced intravenous cholegraphic contrast media produce a greater diagnostic yield in radiological routine thanks to improved roentgenological contrasting. Whereas the percentage share of roentgenologically clearly assessable cases is about 75% when using Biligrafin, this percentage is much higher with the more recent contrast media, especially Biliscopin, namely, up to 88%. These new contrast media are also superior in respect of tolerance, since they produce fewer side effects. While side effects must be expected in about 28% of the cases when injecting Biligrafin, the side effect quota is about 10% only with Biliscopin or Endomirabil. If the contrast medium is infused instead of injected, the quota of side effect drops to 2.3% with Biliscopin or 3.9% with Endomirabil. Slight and medium side effects have definitely decreased with the more recent contrast media. The slower and more continually the contrast medium is administered, the fewer are the side effects observed; this becomes particularly noticeable in the case of long-term infusions. However, the likelihood of severe incidents caused by the contrast medium remains unchanged at about 1% of the examined patients, even with the more recently introduced contrast media. (orig.) [de

  19. Erbium-Based Perfusion Contrast Agent for Small-Animal Microvessel Imaging

    Directory of Open Access Journals (Sweden)

    Justin J. Tse

    2017-01-01

    Full Text Available Micro-computed tomography (micro-CT facilitates the visualization and quantification of contrast-enhanced microvessels within intact tissue specimens, but conventional preclinical vascular contrast agents may be inadequate near dense tissue (such as bone. Typical lead-based contrast agents do not exhibit optimal X-ray absorption properties when used with X-ray tube potentials below 90 kilo-electron volts (keV. We have developed a high-atomic number lanthanide (erbium contrast agent, with a K-edge at 57.5 keV. This approach optimizes X-ray absorption in the output spectral band of conventional microfocal spot X-ray tubes. Erbium oxide nanoparticles (nominal diameter 4000 Hounsfield units, and perfusion of vessels < 10 μm in diameter was demonstrated in kidney glomeruli. The described new contrast agent facilitated the visualization and quantification of vessel density and microarchitecture, even adjacent to dense bone. Erbium’s K-edge makes this contrast agent ideally suited for both single- and dual-energy micro-CT, expanding potential preclinical research applications in models of musculoskeletal, oncological, cardiovascular, and neurovascular diseases.

  20. Characterization of nanoparticle-based contrast agents for molecular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Shan, Liang; Chopra, Arvind; Leung, Kam; Eckelman, William C.; Menkens, Anne E.

    2012-01-01

    The development of molecular imaging agents is currently undergoing a dramatic expansion. As of October 2011, ∼4,800 newly developed agents have been synthesized and characterized in vitro and in animal models of human disease. Despite this rapid progress, the transfer of these agents to clinical practice is rather slow. To address this issue, the National Institutes of Health launched the Molecular Imaging and Contrast Agents Database (MICAD) in 2005 to provide freely accessible online information regarding molecular imaging probes and contrast agents for the imaging community. While compiling information regarding imaging agents published in peer-reviewed journals, the MICAD editors have observed that some important information regarding the characterization of a contrast agent is not consistently reported. This makes it difficult for investigators to evaluate and meta-analyze data generated from different studies of imaging agents, especially for the agents based on nanoparticles. This article is intended to serve as a guideline for new investigators for the characterization of preclinical studies performed with nanoparticle-based MRI contrast agents. The common characterization parameters are summarized into seven categories: contrast agent designation, physicochemical properties, magnetic properties, in vitro studies, animal studies, MRI studies, and toxicity. Although no single set of parameters is suitable to define the properties of the various types of contrast agents, it is essential to ensure that these agents meet certain quality control parameters at the preclinical stage, so that they can be used without delay for clinical studies.

  1. The effect of timing of intravenous muscle relaxant on the quality of double-contrast barium enema

    International Nuclear Information System (INIS)

    Elson, E.M.; Elson, E.M.; Campbell, D.M.; Halligan, S.; Shaikh, I.; Davitt, S.; Bartram, C.I.

    2000-01-01

    AIM: To determine whether the timing of buscopan administration during double-contrast barium enema examination (DCBE) affects diagnostic quality. MATERIALS AND METHODS: In a prospective setting, 100 consecutive adult out-patients referred for DCBE received 20 mg buscopan (hyoscine-N-butylbromide) intravenously, either before infusion of barium suspension (Group A) or after barium infusion and gas insufflation (Group B). A subjective assessment of ease of contrast medium infusion was made at the time of examination and the films subsequently analysed by two radiologists unaware of the mode of relaxant administration, who noted the quality of mucosal coating and made subjective and objective measurements of segmental distension. RESULTS: There was no significant difference in screening times, infusion difficulty or colonic contrast medium coating between the two groups. Subjective assessment of distension of the caecum, ascending colon, transverse colon and rectum were not significantly different. Patients receiving intravenous relaxant after barium and gas infusion had less subjective descending (P = 0.05) and sigmoid (P = 0.04) colon distension, but there was no significant difference with respect to maximal bowel diameter in any of the segments measured. CONCLUSION: The timing of intravenous administration during DCBE is likely to have no significant effect on the diagnostic quality of the study. Elson, E.M. (2000)

  2. The effects of water soluble contrast agents on the respiratory tract

    International Nuclear Information System (INIS)

    Lovett, I.; Donchey, S.; Doust, B.; Branson, J.; Munro, V.

    1989-01-01

    The water soluble contrast agents Gastrografin R (Sodium diatrizoate and meglumine diatrizoate, Schering, Berlin), Iopamiro 300 R (Iopamidol, Schering, Berlin), and Dionosil Aqueous R (propyliodone BP, Glaxo, England) were instilled into the tracheobronchial tree of rats in doses of either 0.1 ml and 0.25 ml. Rats being used as controls, underwent sham operations with the instillation of air instead of contrast agent. In all, 85 rats were used. All rats that had not already died from the effects of contrast agent were sacrificed 30 minutes after instillation. The relative effects of the contrast agents were measured by comparing: survival time; radiographic effects of the contrast agents on the lungs; and pathological changes as estimated by post mortem lung section and microscopy. The least toxic agent was the one with the lowest osmotic activity, namely Aqueous Dionosil. It is therefore recommended that Aqueous Dionosil be used in preference to Gastrografin or Iopamidol for studies of the oesophagus whenever there is a danger of aspiration of contrast agent into the tracheobronchial tree. 11 refs., 3 figs., 5 tabs

  3. Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration.

    Directory of Open Access Journals (Sweden)

    Donghee Park

    Full Text Available Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with

  4. Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration.

    Science.gov (United States)

    Park, Donghee; Song, Gillsoo; Jo, Yongjun; Won, Jongho; Son, Taeyoon; Cha, Ohrum; Kim, Jinho; Jung, Byungjo; Park, Hyunjin; Kim, Chul-Woo; Seo, Jongbum

    2016-01-01

    Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa) causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with microbubbles depends on the

  5. X-ray Scatter Imaging of Hepatocellular Carcinoma in a Mouse Model Using Nanoparticle Contrast Agents

    Science.gov (United States)

    Rand, Danielle; Derdak, Zoltan; Carlson, Rolf; Wands, Jack R.; Rose-Petruck, Christoph

    2015-10-01

    Hepatocellular carcinoma (HCC) is one of the most common malignant tumors worldwide and is almost uniformly fatal. Current methods of detection include ultrasound examination and imaging by CT scan or MRI; however, these techniques are problematic in terms of sensitivity and specificity, and the detection of early tumors (<1 cm diameter) has proven elusive. Better, more specific, and more sensitive detection methods are therefore urgently needed. Here we discuss the application of a newly developed x-ray imaging technique called Spatial Frequency Heterodyne Imaging (SFHI) for the early detection of HCC. SFHI uses x-rays scattered by an object to form an image and is more sensitive than conventional absorption-based x-radiography. We show that tissues labeled in vivo with gold nanoparticle contrast agents can be detected using SFHI. We also demonstrate that directed targeting and SFHI of HCC tumors in a mouse model is possible through the use of HCC-specific antibodies. The enhanced sensitivity of SFHI relative to currently available techniques enables the x-ray imaging of tumors that are just a few millimeters in diameter and substantially reduces the amount of nanoparticle contrast agent required for intravenous injection relative to absorption-based x-ray imaging.

  6. Modeling of ultrasound propagation through contrast agents

    NARCIS (Netherlands)

    Grootens, J.J.F.A.H.; Mischi, M.; Böhmer, M.; Korsten, H.; Aarts, R.M.; Vander Sloten, Jos; Verdonck, Pascal; Nyssen, Marc

    2008-01-01

    In the past years many advances have been made in the detection of ultrasound contrast agents (UCA) by exploiting their nonlinear behavior. However, little attention has been paid to the nonlinear distortion of ultrasound (US) waves propagating through contrast media. The aim of this study is to

  7. Spectral triangulation molecular contrast optical coherence tomography with indocyanine green as the contrast agent

    OpenAIRE

    Yang, Changhuei; McGuckin, Laura E. L.; Simon, John D.; Choma, Michael A.; Applegate, Brian E.; Izatt, Joseph A.

    2004-01-01

    We report a new molecular contrast optical coherence tomography (MCOCT) implementation that profiles the contrast agent distribution in a sample by measuring the agent's spectral differential absorption. The method, spectra triangulation MCOCT, can effectively suppress contributions from spectrally dependent scatterings from the sample without a priori knowledge of the scattering properties. We demonstrate molecular imaging with this new MCOCT modality by mapping the distribution of indocyani...

  8. [Utilization of polymeric micelle magnetic resonance imaging (MRI) contrast agent for theranostic system].

    Science.gov (United States)

    Shiraishi, Kouichi

    2013-01-01

    We applied a polymeric micelle carrier system for the targeting of a magnetic resonance imaging (MRI) contrast agent. Prepared polymeric micelle MRI contrast agent exhibited a long circulation characteristic in blood, and considerable amount of the contrast agent was found to accumulate in colon 26 solid tumor by the EPR effect. The signal intensities of tumor area showed 2-folds increase in T1-weighted images at 24 h after i.v. injection. To observe enhancement of the EPR effect by Cderiv pretreatment on tumor targeting, we used the contrast agent for the evaluation by means of MRI. Cderiv pretreatment significantly enhanced tumor accumulation of the contrast agent. Interestingly, very high signal intensity in tumor region was found at 24 h after the contrast agent injection in Cderiv pretreated mice. The contrast agent visualized a microenvironmental change in tumor. These results indicate that the contrast agent exhibits potential use for tumor diagnostic agent. To combine with a polymeric micelle carrier system for therapeutic agent, the usage of the combination makes a new concept of "theranostic" for a better cancer treatment.

  9. Targeting cancer chemotherapeutic agents by use of lipiodol contrast medium

    International Nuclear Information System (INIS)

    Konno, T.

    1990-01-01

    Arterially administered Lipiodol Ultrafluid contrast medium selectively remained in various malignant solid tumors because of the difference in time required for the removal of Lipiodol contrast medium from normal capillaries and tumor neovasculature. Although blood flow was maintained in the tumor, even immediately after injection Lipiodol contrast medium remained in the neovasculature of the tumor. To target anti-cancer agents to tumors by using Lipiodol contrast medium as a carrier, the characteristics of the agents were examined. Anti-cancer agents had to be soluble in Lipiodol, be stable in it, and separate gradually from it so that the anti-cancer agents would selectively remain in the tumor. These conditions were found to be necessary on the basis of the measurement of radioactivity in VX2 tumors implanted in the liver of 16 rabbits that received arterial injections of 14C-labeled doxorubicin. Antitumor activities and side effects of arterial injections of two types of anti-cancer agents were compared in 76 rabbits with VX2 tumors. Oily anti-cancer agents that had characteristics essential for targeting were compared with simple mixtures of anti-cancer agents with Lipiodol contrast medium that did not have these essential characteristics. Groups of rabbits that received oily anti-cancer agents responded significantly better than groups that received simple mixtures, and side effects were observed more frequently in the groups that received the simple mixtures. These results suggest that targeting of the anti-cancer agent to the tumor is important for treatment of solid malignant tumors

  10. The clinical use of contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bydder, G.M.

    1987-01-01

    Interest in the use of external agents to increase tissue contrasts has come from many sources dating back to the earliest work in NMR, to animal studies and to the widespread use of contrast agents in conventional radiological practice. The first clinical magnetic resonance images were published in 1980 and in the following year a brief account of the use of the paramagnetic agents in human volunteers was established. It was apparent relatively early in the development of magnetic resonance imaging (MRI) that a high level of soft tissue contrast was available de novo and the need for externally administered agents might therefore be small. This observation was tempered by the fact that separation of tumour from oedema was frequently better with contrast enhanced CT X-ray than with unenhanced MRI and that of a contrast agent might therefore be needed for MRI. At the end of 1983 the first parenteral agent gadoliminum diethylene triamine pentaacetic acid (Gd-DTPA) was used in volunteers and clinical studies began in 1984. At the present time only molecular O/sub 2/, oral iron compounds and Gd-DTPA are in clinical use although there are a number of other agents which have been used in animals and some of these may become available for clinical use in the foreseeable future

  11. Excess of Radiation Burden for Young Testicular Cancer Patients using Automatic Exposure Control and Contrast Agent on Whole-body Computed Tomography Imaging.

    Science.gov (United States)

    Niiniviita, Hannele; Kulmala, Jarmo; Pölönen, Tuukka; Määttänen, Heli; Järvinen, Hannu; Salminen, Eeva

    2017-06-01

    The aim of the study was to assess patient dose from whole-body computed tomography (CT) in association with patient size, automatic exposure control (AEC) and intravenous (IV) contrast agent. Sixty-five testicular cancer patients (mean age 28 years) underwent altogether 279 whole-body CT scans from April 2000 to April 2011. The mean number of repeated examinations was 4.3. The GE LightSpeed 16 equipped with AEC and the Siemens Plus 4 CT scanners were used for imaging. Whole-body scans were performed with (216) and without (63) IV contrast. The ImPACT software was used to determine the effective and organ doses. Patient doses were independent (p < 0.41) of patient size when the Plus 4 device (mean 7.4 mSv, SD 1.7 mSv) was used, but with the LightSpeed 16 AEC device, the dose (mean 14 mSv, SD 4.6 mSv) increased significantly (p < 0.001) with waist cirfumference. Imaging with the IV contrast agent caused significantly higher (13% Plus 4, 35% LightSpeed 16) exposure than non-contrast imaging (p < 0.001). Great caution on the use of IV contrast agent and careful set-up of the AEC modulation parameters is recommended to avoid excessive radiation exposure on the whole-body CT imaging of young patients.

  12. MRI contrast agent concentration and tumor interstitial fluid pressure.

    Science.gov (United States)

    Liu, L J; Schlesinger, M

    2016-10-07

    The present work describes the relationship between tumor interstitial fluid pressure (TIFP) and the concentration of contrast agent for dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). We predict the spatial distribution of TIFP based on that of contrast agent concentration. We also discuss the cases for estimating tumor interstitial volume fraction (void fraction or porosity of porous medium), ve, and contrast volume transfer constant, K(trans), by measuring the ratio of contrast agent concentration in tissue to that in plasma. A linear fluid velocity distribution may reflect a quadratic function of TIFP distribution and lead to a practical method for TIFP estimation. To calculate TIFP, the parameters or variables should preferably be measured along the direction of the linear fluid velocity (this is in the same direction as the gray value distribution of the image, which is also linear). This method may simplify the calculation for estimating TIFP. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  13. Computed Tomography Imaging of Solid Tumors Using a Liposomal-Iodine Contrast Agent in Companion Dogs with Naturally Occurring Cancer.

    Science.gov (United States)

    Ghaghada, Ketan B; Sato, Amy F; Starosolski, Zbigniew A; Berg, John; Vail, David M

    2016-01-01

    Companion dogs with naturally occurring cancer serve as an important large animal model in translational research because they share strong similarities with human cancers. In this study, we investigated a long circulating liposomal-iodine contrast agent (Liposomal-I) for computed tomography (CT) imaging of solid tumors in companion dogs with naturally occurring cancer. The institutional animal ethics committees approved the study and written informed consent was obtained from all owners. Thirteen dogs (mean age 10.1 years) with a variety of masses including primary and metastatic liver tumors, sarcomas, mammary carcinoma and lung tumors, were enrolled in the study. CT imaging was performed pre-contrast and at 15 minutes and 24 hours after intravenous administration of Liposomal-I (275 mg/kg iodine dose). Conventional contrast-enhanced CT imaging was performed in a subset of dogs, 90 minutes prior to administration of Liposomal-I. Histologic or cytologic diagnosis was obtained for each dog prior to admission into the study. Liposomal-I resulted in significant (p contrast agent was demonstrated. Liposomal-I enabled visualization of primary and metastatic liver tumors. Sub-cm sized liver lesions grossly appeared as hypo-enhanced compared to the surrounding normal parenchyma with improved lesion conspicuity in the post-24 hour scan. Large liver tumors (> 1 cm) demonstrated a heterogeneous pattern of intra-tumoral signal with visibly higher signal enhancement at the post-24 hour time point. Extra-hepatic, extra-splenic tumors, including histiocytic sarcoma, anaplastic sarcoma, mammary carcinoma and lung tumors, were visualized with a heterogeneous enhancement pattern in the post-24 hour scan. The long circulating liposomal-iodine contrast agent enabled prolonged visualization of small and large tumors in companion dogs with naturally occurring cancer. The study warrants future work to assess the sensitivity and specificity of the Liposomal-I agent in various types of

  14. Severe reactions to iodinated contrast agents: is anaphylaxis responsible?

    International Nuclear Information System (INIS)

    Dewachter, P.; Mouton-Faivre, C.

    2001-01-01

    The etiology of severe reactions following injection of iodinated contrast agent is the subject of controversy. No consensus has been established regarding the management of patients at risk, risk factors and pre-medication because in most cases published no diagnostic exploration has been carried out on patients who have experienced a severe reaction. Diagnosis of drug anaphylaxis is based on clinical history, proof of mediator release and drug specific IgE antibodies (when the technique is available) or cutaneous tests (when direct technique is not available). This approach has been adopted for etiologic diagnosis of 5 clinical cases of severe anaphylactoid reactions (including one death) following the injection of ionic and non ionic contrast agents. Clinical symptoms, biology and cutaneous tests are consistent with anaphylaxis. Any patient who has had a severe anaphylactoid reaction following injection of a contrast agent should undergo an allergology assessment to confirm the diagnosis and identify the culprit contrast agent. Indeed, no pre-medication has proved efficient for the prevention of subsequent allergic reactions. (author)

  15. Magnetosomes used as biogenic MRI contrast agent for molecular imaging of glioblastoma model

    International Nuclear Information System (INIS)

    Boucher, Marianne

    2016-01-01

    This work takes place in the context of molecular imaging, which aims at tailoring medical treatments and therapies to the individual context by revealing molecular or cellular phenomenon of medical interest in the less invasive manner. In particular, it can be achieved with MRI molecular imaging using engineered iron-oxide contrast agent.This PhD thesis focuses on the study of a new class of iron-oxide contrast agent for high field MRI. Indeed, magnetosomes are natural iron-oxide vesicles produced by magneto-tactic bacteria. These bacteria synthesized such magnetic vesicles and ordered them like a nano-compass in order to facilitate their navigation in sediments. This explains why magnetosomes are awarded with tremendous magnetic properties: around 50 nm, mono-crystalline, single magnetic domain and high saturation magnetization. Furthermore, a wide variety of bacterial strains exist in nature and size and shape of magnetosomes are highly stable within strain and can be very different between strains. Finally, magnetosomes are naturally coated with a bi-lipidic membrane whose content is genetically determined. Lately, researchers have unravelled magnetosomes membrane protein contents, opening the way to create functionalized magnetosomes thanks to fusion of the gene coding for a protein of interest with the gene coding for an abundant protein at magnetosomes membrane.A new alternative path using living organisms to tackle the production of engineered high efficiency molecular imaging probes have been investigated with magneto-tactic bacteria in this PhD. The production and engineering of magnetosomes have been carried out by our partner, the Laboratoire de Bio-energetique Cellulaire (LBC, CEA Cadarache), and will be presented and discussed. We then characterized magnetosomes as contrast agent for high field MRI. We showed they present very promising contrasting properties in vitro, and assessed this observation in vivo by establishing they can be used as efficient

  16. The use of contrast media for quality assurance in treatment planning

    International Nuclear Information System (INIS)

    Schultze, J.; Eilf, K.; Zimmermann, J.; Kimmig, B.

    1995-01-01

    In 1303 simulations between 1.1.1993 and 30.9.1993 105 times intravenous contrast media were applied, supplied by oral or endolymphatic contrast agents. It was studied if the previously intended plan had to be altered due to contrast media application. In 17 out of 105 cases (16.2%) the target volume or the preplanned technique had to be altered after contrast media application. Main reason was the existence of anatomical variations especially in kidney and small bowel detected by use of contrast agents. So standard indications for contrast media applications were defined. (orig.) [de

  17. Novel MR imaging contrast agents for cancer detection

    Directory of Open Access Journals (Sweden)

    Daryoush Shahbazi-Gahrouei

    2009-05-01

    Full Text Available

    • BACKGROUND: Novel potential MR imaging contrast agents Gd-tetra-carboranylmethoxyphenyl-porphyrin (Gd-TCP, Gd-hematoporphyrin (Gd-H, Gd-DTPA-9.2.27 against melanoma, Gd-DTPA-WM53 against leukemia and Gd-DTPAC595 against breast cancer cells were synthesized and applied to mice with different human cancer cells (melanoma MM-138, leukemia HL-60, breast MCF-7. The relaxivity, the biodistribution, T1 relaxation times, and signal enhancement of the contrast agents are presented and the results are compared.
    • METHODS: After preparation of contrast agents, the animal studies were performed. The cells (2×106 cells were injected subcutaneously in the both flanks of mice. Two to three weeks after tumor plantation, when the tumor diameter was 2-4 mm, mice were injected with the different contrast agents. The animals were sacrificed at 24 hr post IP injection followed by removal of critical organs. The T1 relaxation times and signal intensities of samples were measured using 11.4 T magnetic field and Gd concentration were measured using UV-spectrophotometer.
    • RESULTS: For Gd-H, the percent of Gd localized to the tumors measured by UV-spect was 28, 23 and 21 in leukemia, melanoma and breast cells, respectively. For Gd-TCP this amount was 21%, 18% and 15%, respectively. For Gd-DTPA-9.2.27, Gd-DTPA-WM53 and Gd-DTPA-C595 approximately 35%, 32% and 27% of gadolinium localized to their specific tumor, respectively.
    • CONCLUSION: The specific studied conjugates showed good tumor uptake in the relevant cell lines and low levels of Gd in the liver, kidney and spleen. The studied agents have considerable promise for further diagnosis applications of MR imaging.
    • KEYWORDS: Magnetic Resonance, Imaging, Monoclonal Antibody, Contrast Agents, Gadolinium, Early Detection of Cancer.

  18. Efficacy of pamiray as a nonionic intravenous contrast material; experimental study suing normal rabbits

    International Nuclear Information System (INIS)

    Lee, Joon Woo; Kim, Tae Kyoung; Kim, Seung Hyup; Kim, Hyun Beom; Kim, Se Hyung; Hwang, Sung Il; Yeon, Kyung Mo

    2000-01-01

    To evaluate the efficacy of Pamiray as an intravenous nonionic contrast material by comparing it with an established nonionic contrast material (Iopamiro). Forty adult New Zealand white rabbits weighing about 3.0 kg were used in this study. Aortography and urography (scout, 5, 15 and 30 minutes delay after injection) were performed in ten rabbits with Pamiray (370 mgI/mL) and in other ten rabbits with Iopamiro (370 mgI/mL). All twenty rabbits underwent abdominal triple-phase spiral CT before and 5 and 30 seconds after injection of the contrast material. The degree of contrast enhancement seen on aortograms and intravenous urograms was determined using a three-point scale by two radiologists, who reached a consensus. CT attenuation expressed in Hounsfield units (HU) was measured using the regions of interest (ROIs) facility in the liver, bilateral kidneys, aorta, portal vein, and inferior vena cave. The Mann-Whitney U test was used in image evaluation for intergroup comparisons. There was no significant difference between the two groups in the degree of contrast enhancement seen on aortograms. In urography, however, Iopamiro was superior to Pamiray in demonstrating calyces of the right kidney on 15-minute delay images and Pamiray was superior to Iopamiro in demonstrating the right ureter and the renal pelvis on five minute-delay images and the left ureter on 30 minutes delay (p less than 0.05). Peak enhancement of the aorta during the first phase of abdominal CT was higher in the group in which Pamiray was used. When normal rabbits were used for aortography, abdominal CT, and urography, Pamiray provided more effective contrast enhancement than a previously used nonionic contrast material, namely Iopamiro. There were, however, slight differences in the enhancement features of renal calyces and ureters seen on 5- and 15-minute urograms. (author)

  19. Cyanine 5.5 conjugated nanobubbles as a tumor selective contrast agent for dual ultrasound-fluorescence imaging in a mouse model.

    Directory of Open Access Journals (Sweden)

    Liyi Mai

    Full Text Available Nanobubbles and microbubbles are non-invasive ultrasound imaging contrast agents that may potentially enhance diagnosis of tumors. However, to date, both nanobubbles and microbubbles display poor in vivo tumor-selectivity over non-targeted organs such as liver. We report here cyanine 5.5 conjugated nanobubbles (cy5.5-nanobubbles of a biocompatible chitosan-vitamin C lipid system as a dual ultrasound-fluorescence contrast agent that achieved tumor-selective imaging in a mouse tumor model. Cy5.5-nanobubble suspension contained single bubble spheres and clusters of bubble spheres with the size ranging between 400-800 nm. In the in vivo mouse study, enhancement of ultrasound signals at tumor site was found to persist over 2 h while tumor-selective fluorescence emission was persistently observed over 24 h with intravenous injection of cy5.5-nanobubbles. In vitro cell study indicated that cy5.5-flurescence dye was able to accumulate in cancer cells due to the unique conjugated nanobubble structure. Further in vivo fluorescence study suggested that cy5.5-nanobubbles were mainly located at tumor site and in the bladder of mice. Subsequent analysis confirmed that accumulation of high fluorescence was present at the intact subcutaneous tumor site and in isolated tumor tissue but not in liver tissue post intravenous injection of cy5.5-nanobubbles. All these results led to the conclusion that cy5.5-nanobubbles with unique crosslinked chitosan-vitamin C lipid system have achieved tumor-selective imaging in vivo.

  20. Critical Questions Regarding Gadolinium Deposition in the Brain and Body After Injections of the Gadolinium-Based Contrast Agents, Safety, and Clinical Recommendations in Consideration of the EMA's Pharmacovigilance and Risk Assessment Committee Recommendation for Suspension of the Marketing Authorizations for 4 Linear Agents.

    Science.gov (United States)

    Runge, Val M

    2017-06-01

    For magnetic resonance, the established class of intravenous contrast media is the gadolinium-based contrast agents. In the 3 decades since initial approval, these have proven in general to be very safe for human administration. However, in 2006, a devastating late adverse reaction to administration of the less stable gadolinium-based contrast agents was identified, nephrogenic systemic fibrosis. The result of actions taken by the European Medicines Agency and the US Food and Drug Administration, stratifying the agents by risk and contraindicating specific agents in severe renal dysfunction, has led to no new cases being identified in North America or Europe. Subsequently, in 2014, long-term deposition in the brain of gadolinium was first shown, after administration of 2 nonionic linear chelates, gadodiamide, and gadopentetate dimeglumine. This has led to an intense focus on the question of in vivo distribution, possible dechelation, and subsequent deposition of gadolinium, together with substantial clarification of the phenomenon as well as stratification of the agents on this basis. This review focuses on 8 critical questions regarding gadolinium deposition in the brain and body, with the answers and discussion therein important for future regulatory decisions and clinical practice. It is now clear that dechelation of gadolinium occurs in vivo with the linear agents and is responsible for this phenomenon, with key experts in the field recommending, except where there is no suitable alternative, a shift in clinical practice from the linear to macrocyclic agents. In addition, on March 10, 2017, the Pharmacovigilance and Risk Assessment Committee of the European Medicines Agency recommended suspension of the marketing authorization for 4 linear gadolinium contrast agents-specifically Omniscan, Optimark, Magnevist, and MultiHance (gadodiamide, gadoversetamide, gadopentetate dimeglumine, and gadobenate dimeglumine)-for intravenous injection. Cited in the report was

  1. MRI and CT contrast media extravasation

    Science.gov (United States)

    Heshmatzadeh Behzadi, Ashkan; Farooq, Zerwa; Newhouse, Jeffery H.; Prince, Martin R.

    2018-01-01

    Abstract Background: This systematic review combines data from multiple papers on contrast media extravasation to identify factors contributing to increased extravasation risk. Methods: Data were extracted from 17 papers reporting 2191 extravasations in 1,104,872 patients (0.2%) undergoing computed tomography (CT) or magnetic resonance imaging (MRI). Results: Extravasation rates were 0.045% for gadolinium-based contrast agents (GBCA) and nearly 6-fold higher, 0.26% for iodinated contrast agents. Factors associated with increased contrast media extravasations included: older age, female gender, using an existing intravenous (IV) instead of placing a new IV in radiology, in-patient status, use of automated power injection, high injection rates, catheter location, and failing to warm up the more viscous contrast media to body temperature. Conclusion: Contrast media extravasation is infrequent but nearly 6 times less frequent with GBCA for MRI compared with iodinated contrast used in CT. PMID:29489663

  2. Macromolecular and dendrimer-based magnetic resonance contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Bumb, Ambika; Brechbiel, Martin W. (Radiation Oncology Branch, National Cancer Inst., National Inst. of Health, Bethesda, MD (United States)), e-mail: pchoyke@mail.nih.gov; Choyke, Peter (Molecular Imaging Program, National Cancer Inst., National Inst. of Health, Bethesda, MD (United States))

    2010-09-15

    Magnetic resonance imaging (MRI) is a powerful imaging modality that can provide an assessment of function or molecular expression in tandem with anatomic detail. Over the last 20-25 years, a number of gadolinium-based MR contrast agents have been developed to enhance signal by altering proton relaxation properties. This review explores a range of these agents from small molecule chelates, such as Gd-DTPA and Gd-DOTA, to macromolecular structures composed of albumin, polylysine, polysaccharides (dextran, inulin, starch), poly(ethylene glycol), copolymers of cystamine and cystine with GD-DTPA, and various dendritic structures based on polyamidoamine and polylysine (Gadomers). The synthesis, structure, biodistribution, and targeting of dendrimer-based MR contrast agents are also discussed

  3. In vivo Photoacoustic Imaging of Prostate Cancer Using Targeted Contrast Agent

    Science.gov (United States)

    2016-11-01

    AD______________ AWARD NUMBER: W81XWH-14-1-0242 TITLE: In Vivo Photoacoustic Imaging of Prostate Cancer Using Targeted Contrast Agent PRINCIPAL...TITLE AND SUBTITLE In vivo Photoacoustic Imaging of Prostate Cancer Using T argeted Contrast Agent 5a. CONTRACT NUMBER W81XWH-14-1-0242 5b. GRANT...diagnose prostate cancer based on the near-infrared optical absorption of either endogenous tissue constituents or exogenous contrast agents . Although

  4. Should nonionic radiographic contrast media be given to all patients?

    International Nuclear Information System (INIS)

    Parfrey, P.S.; Cramer, B.C.; McManamon, P.J.

    1988-01-01

    In the 1970s about one patient of every 40,000 who underwent intravenous urography died. It has been suggested that lives can be saved by using only nonionic or low-osmolarity contrast agents. The authors suggest a multicentre double-blind randomized controlled trial of nonionic versus ionic contrast media

  5. Synthesis of ultrasound contrast agents: characteristics and size distribution analysis (secondary publication)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hak Jong [Program in Nano Science and Technology, Dept. of Transdisciplinary Studies, Seoul National University Graduate School of Convergence Science and Technology, Seoul (Korea, Republic of); Yoon, Tae Jong [Dept. of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); Yoon, Young Il [Dept. of Applied Bioscience, CHA University, Pocheon (Korea, Republic of)

    2017-10-15

    The purpose of this study was to establish a method for ultrasound (US) contrast agent synthesis and to evaluate the characteristics of the synthesized US contrast agent. A US contrast agent, composed of liposome and sulfur hexafluoride (SF6), was synthesized by dissolving 21 μmol 1,2-dihexadecanoyl-sn-glycero-3-phosphocholine (DPPC, C40H80NO8P), 9 μmol cholesterol, and 1.9 μmol of dihexadecylphosphate (DCP, [CH3(CH2)15O]2P(O)OH) in chloroform. After evaporation in a warm water bath and drying for 12-24 hours, the contrast agent was synthesized using the sonication process by the addition of a buffer and SF6 gas. The size distribution of the bubbles was analyzed using dynamic light scattering measurement methods. The degradation curve was evaluated by assessing the change in the number of contrast agent bubbles using light microscopy immediately, 12, 24, 36, 48, 60, 72, and 84 hours after synthesis. The echogenicity of the synthesized microbubbles was compared with commercially available microbubbles (SonoVue, Bracco). contrast agent was synthesized successfully using an evaporation-drying-sonication method. Most bubbles had a mean diameter of 154.2 nm and showed marked degradation 24 hours after synthesis. Although no statistically significant differences were observed between SonoVue and the synthesized contrast agent, a difference in echogenicity was observed between the synthesized contrast agent and saline (P<0.01). We successfully synthesized a US contrast agent using an evaporation-dryingsonication method. These results may help future research in the fields of anticancer drug delivery, gene delivery, targeted molecular imaging, and targeted therapy.

  6. Synthesis of ultrasound contrast agents: characteristics and size distribution analysis (secondary publication)

    International Nuclear Information System (INIS)

    Lee, Hak Jong; Yoon, Tae Jong; Yoon, Young Il

    2017-01-01

    The purpose of this study was to establish a method for ultrasound (US) contrast agent synthesis and to evaluate the characteristics of the synthesized US contrast agent. A US contrast agent, composed of liposome and sulfur hexafluoride (SF6), was synthesized by dissolving 21 μmol 1,2-dihexadecanoyl-sn-glycero-3-phosphocholine (DPPC, C40H80NO8P), 9 μmol cholesterol, and 1.9 μmol of dihexadecylphosphate (DCP, [CH3(CH2)15O]2P(O)OH) in chloroform. After evaporation in a warm water bath and drying for 12-24 hours, the contrast agent was synthesized using the sonication process by the addition of a buffer and SF6 gas. The size distribution of the bubbles was analyzed using dynamic light scattering measurement methods. The degradation curve was evaluated by assessing the change in the number of contrast agent bubbles using light microscopy immediately, 12, 24, 36, 48, 60, 72, and 84 hours after synthesis. The echogenicity of the synthesized microbubbles was compared with commercially available microbubbles (SonoVue, Bracco). contrast agent was synthesized successfully using an evaporation-drying-sonication method. Most bubbles had a mean diameter of 154.2 nm and showed marked degradation 24 hours after synthesis. Although no statistically significant differences were observed between SonoVue and the synthesized contrast agent, a difference in echogenicity was observed between the synthesized contrast agent and saline (P<0.01). We successfully synthesized a US contrast agent using an evaporation-dryingsonication method. These results may help future research in the fields of anticancer drug delivery, gene delivery, targeted molecular imaging, and targeted therapy

  7. Use of carbon dioxide as an intravascular contrast agent: A review of current literature

    OpenAIRE

    Ali, Fahad; Mangi, Muhammad Asif; Rehman, Hiba; Kaluski, Edo

    2017-01-01

    Use of X-ray contrast allows us to differentiate between two or more adjacent structures on radiographic studies. The X-ray contrast agent can be the one with increase X-ray absorption, like iodine and a barium X-ray contrast agent or the one with decrease X-ray absorption like air and carbon dioxide contrast agent. Each contrast agent possesses different risks and benefits in various ways. Carbon dioxide as an intravascular contrast agent can be used as an alternative intravascular contrast ...

  8. Gadolinium heteropoly complex K 17[Gd(P 2W 17O 61) 2] as a potential MRI contrast agent

    Science.gov (United States)

    Sun, Guoying; Feng, Jianghua; Wu, Huifeng; Pei, Fengkui; Fang, Ke; Lei, Hao

    2004-10-01

    Gadolinium heteropoly complex K17[Gd(P2W17O61)2] has been evaluated by in vitro and in vivo experiments as a potential contrast agent for magnetic resonance imaging (MRI). The thermal analysis and conductivity study indicate that this complex has good thermal stability and wide pH stability range. The T1 relaxivity is 7.59 mM-1 s-1 in aqueous solution and 7.97 mM-1 s-1 in 0.725 mmol l-1 bovine serum albumin (BSA) solution at 25 °C and 9.39 T, respectively. MR imaging of three male Sprague-Dawley rats showed remarkable enhancement in rat liver after intravenous injection, which persisted longer than with Gd-DTPA. The signal intensity increased by 57.1±16.9% during the whole imaging period at 0.082 mmol kg-1dose. Our preliminary in vitro and in vivo studies indicate that K17[Gd(P2W17O61)2] is a potential liver-specific MRI contrast agent.

  9. Iron Oxide as an MRI Contrast Agent for Cell Tracking

    Science.gov (United States)

    Korchinski, Daniel J.; Taha, May; Yang, Runze; Nathoo, Nabeela; Dunn, Jeff F.

    2015-01-01

    Iron oxide contrast agents have been combined with magnetic resonance imaging for cell tracking. In this review, we discuss coating properties and provide an overview of ex vivo and in vivo labeling of different cell types, including stem cells, red blood cells, and monocytes/macrophages. Furthermore, we provide examples of applications of cell tracking with iron contrast agents in stroke, multiple sclerosis, cancer, arteriovenous malformations, and aortic and cerebral aneurysms. Attempts at quantifying iron oxide concentrations and other vascular properties are examined. We advise on designing studies using iron contrast agents including methods for validation. PMID:26483609

  10. Application of gold nanoparticles as contrast agents in confocal laser scanning microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lemelle, A; Veksler, B; Piletsky, S A; Meglinski, I [Cranfield Health, Cranfield University, Cranfield, MK43 0AL (United Kingdom); Kozhevnikov, I S; Akchurin, G G, E-mail: a.lemelle.s06@cranfield.ac.uk [Physics Faculty, Saratov State University, Saratov 410012 (Russian Federation)

    2009-01-15

    Confocal laser scanning microscopy (CLSM) is a modern high-resolution optical technique providing detailed image of tissue structure with high (down to microns) spatial resolution. Aiming at a concurrent improvement of imaging depth and image quality the CLSM requires the use of contrast agents. Commonly employed fluorescent contrast agents, such as fluorescent dyes and proteins, suffer from toxicity, photo-bleaching and overlapping with the tissues autofluorescence. Gold nanoparticles are potentially highly attractive to be applied as a contrast agent since they are not subject to photo-bleaching and can target biochemical cells markers associated with the specific diseases. In current report we consider the applicability of gold nano-spheres as a contrast agent to enhance quality of CLSM images of skin tissues in vitro versus the application of optical clearing agent, such as glycerol. The enhancement of CLSM image contrast was observed with an application of gold nano-spheres diffused within the skin tissues. We show that optical clearing agents such as a glycerol provide better CLSM image contrast than gold nano-spheres.

  11. Application of gold nanoparticles as contrast agents in confocal laser scanning microscopy

    International Nuclear Information System (INIS)

    Lemelle, A; Veksler, B; Piletsky, S A; Meglinski, I; Kozhevnikov, I S; Akchurin, G G

    2009-01-01

    Confocal laser scanning microscopy (CLSM) is a modern high-resolution optical technique providing detailed image of tissue structure with high (down to microns) spatial resolution. Aiming at a concurrent improvement of imaging depth and image quality the CLSM requires the use of contrast agents. Commonly employed fluorescent contrast agents, such as fluorescent dyes and proteins, suffer from toxicity, photo-bleaching and overlapping with the tissues autofluorescence. Gold nanoparticles are potentially highly attractive to be applied as a contrast agent since they are not subject to photo-bleaching and can target biochemical cells markers associated with the specific diseases. In current report we consider the applicability of gold nano-spheres as a contrast agent to enhance quality of CLSM images of skin tissues in vitro versus the application of optical clearing agent, such as glycerol. The enhancement of CLSM image contrast was observed with an application of gold nano-spheres diffused within the skin tissues. We show that optical clearing agents such as a glycerol provide better CLSM image contrast than gold nano-spheres

  12. Application of gold nanoparticles as contrast agents in confocal laser scanning microscopy

    Science.gov (United States)

    Lemelle, A.; Veksler, B.; Kozhevnikov, I. S.; Akchurin, G. G.; Piletsky, S. A.; Meglinski, I.

    2009-01-01

    Confocal laser scanning microscopy (CLSM) is a modern high-resolution optical technique providing detailed image of tissue structure with high (down to microns) spatial resolution. Aiming at a concurrent improvement of imaging depth and image quality the CLSM requires the use of contrast agents. Commonly employed fluorescent contrast agents, such as fluorescent dyes and proteins, suffer from toxicity, photo-bleaching and overlapping with the tissues autofluorescence. Gold nanoparticles are potentially highly attractive to be applied as a contrast agent since they are not subject to photo-bleaching and can target biochemical cells markers associated with the specific diseases. In current report we consider the applicability of gold nano-spheres as a contrast agent to enhance quality of CLSM images of skin tissues in vitro versus the application of optical clearing agent, such as glycerol. The enhancement of CLSM image contrast was observed with an application of gold nano-spheres diffused within the skin tissues. We show that optical clearing agents such as a glycerol provide better CLSM image contrast than gold nano-spheres.

  13. Polydisulfide Manganese(II) Complexes as Non-Gadolinium Biodegradable Macromolecular MRI Contrast Agents

    Science.gov (United States)

    Ye, Zhen; Jeong, Eun-Kee; Wu, Xueming; Tan, Mingqian; Yin, Shouyu; Lu, Zheng-Rong

    2011-01-01

    Purpose To develop safe and effective manganese(II) based biodegradable macromolecular MRI contrast agents. Materials and Methods In this study, we synthesized and characterized two polydisulfide manganese(II) complexes, Mn-DTPA cystamine copolymers and Mn-EDTA cystamine copolymers, as new biodegradable macromolecular MRI contrast agents. The contrast enhancement of the two manganese based contrast agents were evaluated in mice bearing MDA-MB-231 human breast carcinoma xenografts, in comparison with MnCl2. Results The T1 and T2 relaxivities were 4.74 and 10.38 mM−1s−1 per manganese at 3T for Mn-DTPA cystamine copolymers (Mn=30.50 kDa) and 6.41 and 9.72 mM−1s−1 for Mn-EDTA cystamine copolymers (Mn= 61.80 kDa). Both polydisulfide Mn(II) complexes showed significant liver, myocardium and tumor enhancement. Conclusion The manganese based polydisulfide contrast agents have a potential to be developed as alternative non-gadolinium contrast agents for MR cancer and myocardium imaging. PMID:22031457

  14. Therapeutic response assessment of percutaneous radiofrequency ablation for hepatocellular carcinoma: Utility of contrast-enhanced agent detection imaging

    International Nuclear Information System (INIS)

    Kim, Chan Kyo; Choi, Dongil; Lim, Hyo K.; Kim, Seung Hoon; Lee, Won Jae; Kim, Min Ju; Lee, Ji Yeon; Jeon, Yong Hwan; Lee, Jongmee; Lee, Soon Jin; Lim, Jae Hoon

    2005-01-01

    Purpose: To assess the utility of contrast-enhanced agent detection imaging (ADI) in the assessment of the therapeutic response to percutaneous radiofrequency (RF) ablation in patients with hepatocellular carcinoma (HCC). Materials and methods: Ninety patients with a total of 97 nodular HCCs (mean, 2.1 ± 1.3 cm; range, 1.0-5.0 cm) treated with percutaneous RF ablation under the ultrasound guidance were evaluated with contrast-enhanced ADI after receiving an intravenous bolus injection of a microbubble contrast agent (SH U 508A). We obtained serial contrast-enhanced ADI images during the time period from 15 to 90 s after the initiation of the bolus contrast injection. All of the patients underwent a follow-up four-phase helical CT at 1 month after RF ablation, which was then repeated at 2-4 month intervals during a period of at least 12 months. The results of the contrast-enhanced ADI were compared with those of the follow-up CT in terms of the presence or absence of residual unablated tumor and local tumor progression in the treated lesions. Results: On contrast-enhanced ADI, technical success was obtained in 94 (97%) of the 97 HCCs, while residual unablated tumors were found in three HCCs (3%). Two of the three tumors that were suspicious (was not proven) for incomplete ablation were subjected to additional RF ablation. The remaining one enhancing lesion that was suspicious of a residual tumor on contrast-enhanced ADI was revealed to be reactive hyperemia at the 1-month follow-up CT. Therefore; the diagnostic concordance between the contrast-enhanced ADI and 1-month follow-up CT was 99%. Of the 94 ablated HCCs without residual tumors on both the contrast-enhanced ADI and 1-month follow-up CT after the initial RF ablation, five (5%) had CT findings of local tumor progression at a subsequent follow-up CT. Conclusion: Despite its limitations in predicting local tumor progression in the treated tumors, contrast-enhanced ADI is potentially useful for evaluating the

  15. Iron oxide contrast media improve MR-imaging of the portal venous system -an experimental study

    International Nuclear Information System (INIS)

    Boeck, J.C.; Knollmann, F.D.; Teltenkoetter, S.; Wlodarcyk, W.; Muehler, A.; Felix, R.

    1997-01-01

    Purpose: The aim was to demonstrate that intravenous superparamagnetic iron oxide contrast agents improve the delineation of the portal venous system. Material and methods: The portal venous system of 8 minipigs was demonstrated by a FLASH 2-D MRA-sequence. Scans were acquired before and after intravenous administration of 10 and 20 μmol/kg of a superparamagnetic iron oxide contrast agent (SHU 555 A). Signal intensities were measured in the portal vein and hepatic parenchym and contrast-to-noise ratios were calculated. Results: Following a cumulative dose of 10 μmol iron oxide, hepatic parenchymal signal intensity decreased to 67±6%, following 20 μmol to 29±4%, and following 40 μmol to 13±2% of control (p [de

  16. Investigation of contrast agent dosage for perfusion-weighted MRI

    International Nuclear Information System (INIS)

    Erb, G.; Benner, T.; Heiland, S.; Reith, W.; Sartor, K.; Forsting, M.

    1997-01-01

    Purpose: In this study we investigated, whether increasing the dosage of a paramagnetic contrast agent results in a stronger signal decrease in T 2 *-weighted perfusion sequences and therefore more meaningful parameter maps. Material and methods: In a prospective study bolus injection of gadolinium-DTPA was performed at dosages of 0.1, 0.2, and 0.3 mmol/kg body weight (BW) in 10 patients each. Before, during and after bolus injection 40 T 2 *-weighted images of a reference brain slice were acquired within 65.6 seconds on a 1.0 T clinical scanner and perfusion parameters were calculated. Results: Due to the limited signal decrease during bolus passage and the resulting low signal-difference-to-noise ratio (ΔS/N) no reliable differentiation of gray and white matter was possible at a contrast agent dosage of 0.1 mmol/kg BW. Only at higher dosages, both, signal decrease and ΔS/N were strong enough to allow differentiation of gray and white matter and to yield reliable parameter maps. Conclusion: For meaningful MR perfusion imaging at 1.0 T and with the given sequence a contrast agent dosage of at least 0.2 mmol/kg BW is necessary, if a 0.5-molar contrast agent is used. (orig.) [de

  17. Value of intravenous injection of contrast media for computerized tomography of the thorax

    International Nuclear Information System (INIS)

    Beyer-Enke, S.A.; Goerich, J.; Mueller, M.; Kaick, G. van; Tuengerthal, S.

    1988-01-01

    107 patients with thoracal or mediastinal growths underwent computerized tomography of the thorax both in normal condition and after receiving intravenous applications of non-ionic X-ray contrast media. The additional information obtained by use of contrast media was established in relation to the histological findings. The method led to enhanced demarcation of the tumor of the mediastinum or hilus in 40% of the patients. Tumor perfusion was helpful in 20% of the cases for differential diagnosis. Vessel infiltrations or abnormal conditions were found in about 30% of patients. 24% of the tests yielded no additional information. Analysing CT as compared to the histological examination of lymph nodes proved CT under normal conditions to be a sensitive method in 29% of cases if the hilus was the site of the tumor; contrast media raised this sensitivity to 43%. In the mediastinal area, sensitivity was 44% without and 56% with contrast media. (orig.) [de

  18. Anaphylactoid reactions after iodinated contrast media

    International Nuclear Information System (INIS)

    Strejcek, J.; Sehr, A.

    1987-01-01

    A survey is presented of data published in the literature on the incidence of undesirable and especially anaphylactoid reactions to intravenously administered iodinated contrast media used in radiodiagnosis, this with regard to age, sex, allergy in the patient's history, previously administered contrast media, possible previous reaction. A detailed description is presented of the assumed mechanisms of these reactions. There does not exist any reliable premedication. It is always indispensable to consider the indications of the examination using iodinated contrast agents and the possibilities of immediate and qualified resuscitation. (author). 2 tabs., 36 refs

  19. Highly biocompatible TiO2:Gd3+ nano-contrast agent with enhanced longitudinal relaxivity for targeted cancer imaging

    Science.gov (United States)

    Chandran, Parwathy; Sasidharan, Abhilash; Ashokan, Anusha; Menon, Deepthy; Nair, Shantikumar; Koyakutty, Manzoor

    2011-10-01

    We report the development of a novel magnetic nano-contrast agent (nano-CA) based on Gd3+ doped amorphous TiO2 of size ~25 nm, exhibiting enhanced longitudinal relaxivity (r1) and magnetic resonance (MR) contrasting together with excellent biocompatibility. Quantitative T1 mapping of phantom samples using a 1.5 T clinical MR imaging system revealed that the amorphous phase of doped titania has the highest r1 relaxivity which is ~2.5 fold higher than the commercially used CA Magnevist™. The crystalline (anatase) samples formed by air annealing at 250 °C and 500 °C showed significant reduction in r1 values and MR contrast, which is attributed to the loss of proton-exchange contribution from the adsorbed water and atomic re-arrangement of Gd3+ ions in the crystalline host lattice. Nanotoxicity studies including cell viability, plasma membrane integrity, reactive oxygen stress and expression of pro-inflammatory cytokines, performed on human primary endothelial cells (HUVEC), human blood derived peripheral blood mononuclear cells (PBMC) and nasopharyngeal epidermoid carcinoma (KB) cell line showed excellent biocompatibility up to relatively higher doses of 200 μg ml-1. The potential of this nano-CA to cause hemolysis, platelet aggregation and plasma coagulation were studied using human peripheral blood samples and found no adverse effects, illustrating the possibility of the safe intravenous administration of these agents for human applications. Furthermore, the ability of these agents to specifically detect cancer cells by targeting molecular receptors on the cell membrane was demonstrated on folate receptor (FR) positive oral carcinoma (KB) cells, where the folic acid conjugated nano-CA showed receptor specific accumulation on cell membrane while leaving the normal fibroblast cells (L929) unstained. This study reveals that the Gd3+ doped amorphous TiO2 nanoparticles having enhanced magnetic resonance contrast and high biocompatibility is a promising candidate for

  20. Ultrasound contrast-agent improves imaging of lower limb occlusive disease

    DEFF Research Database (Denmark)

    Eiberg, J P; Hansen, M A; Jensen, F

    2003-01-01

    to evaluate if ultrasound contrast-agent infusion could improve duplex-ultrasound imaging of peripheral arterial disease (PAD) and increase the agreement with digital subtraction arteriography (DSA).......to evaluate if ultrasound contrast-agent infusion could improve duplex-ultrasound imaging of peripheral arterial disease (PAD) and increase the agreement with digital subtraction arteriography (DSA)....

  1. Intravenous Versus Subcutaneous Anti-TNF-Alpha Agents for Crohn's Disease: A Comparison of Effectiveness and Safety.

    Science.gov (United States)

    Liu, Jinan; Sylwestrzak, Gosia; Ruggieri, Alexander P; DeVries, Andrea

    2015-07-01

    In recent years, there have been a number of pharmacological innovations for Crohn's disease (CD), a difficult-to-treat condition, including new treatment philosophies (e.g., top-down therapy) and new therapeutic options in terms of the agent and the route of administration. Three anti-tumor necrosis factor (anti-TNF-alpha) agents are available for use among CD patients in the United States: infliximab, an intravenous agent, and adalimumab and certolizumab pegol, 2 newer subcutaneous products. Infliximab is considered the "gold standard" because it has the longest clinical experience, and adalimumab and certolizumab pegol have each gained significant market share. To examine differences in effectiveness and safety between currently available intravenous and subcutaneous anti-TNF-alpha agents used to treat patients with CD. Data for this retrospective, administrative claims analysis were obtained from pharmacy and medical claims from major U.S. health plans geographically dispersed across 14 states during 2007-2011. Patients had at least 1 ICD-9-CM diagnosis for CD, 6 months pre-index eligibility, and initiated anti-TNF-alpha therapy on the index date. Patients in each cohort were propensity score matched on pre-index demographics, clinical characteristics, and baseline health care use. During the post-index period, age-sex adjusted incidence rate ratios (IRRs) of CD-related symptoms, infections, cancers, and hepatic-related conditions were compared using Cox (PH) models. The matched cohorts included 515 patients in each group, with an average age of 39 years. Median follow-up was 17.5 months in the intravenous cohort and 17.7 months in the subcutaneous cohort. In terms of effectiveness outcomes, age-sex adjusted IRRs for the subcutaneous group, with the intravenous cohort as a reference, were as follows: 0.61 (95% CI = 0.32-1.18, P = 0.14) for anal fissures; 0.97 (95% CI = 0.72-1.30, P = 0.85) for abscess; 1.08 (95% CI = 0.79-1.04, P = 0

  2. Biocompatible Nanocomplexes for Molecular Targeted MRI Contrast Agent

    Science.gov (United States)

    Chen, Zhijin; Yu, Dexin; Wang, Shaojie; Zhang, Na; Ma, Chunhong; Lu, Zaijun

    2009-07-01

    Accurate diagnosis in early stage is vital for the treatment of Hepatocellular carcinoma. The aim of this study was to investigate the potential of poly lactic acid-polyethylene glycol/gadolinium-diethylenetriamine-pentaacetic acid (PLA-PEG/Gd-DTPA) nanocomplexes using as biocompatible molecular magnetic resonance imaging (MRI) contrast agent. The PLA-PEG/Gd-DTPA nanocomplexes were obtained using self-assembly nanotechnology by incubation of PLA-PEG nanoparticles and the commercial contrast agent, Gd-DTPA. The physicochemical properties of nanocomplexes were measured by atomic force microscopy and photon correlation spectroscopy. The T1-weighted MR images of the nanocomplexes were obtained in a 3.0 T clinical MR imager. The stability study was carried out in human plasma and the distribution in vivo was investigated in rats. The mean size of the PLA-PEG/Gd-DTPA nanocomplexes was 187.9 ± 2.30 nm, and the polydispersity index was 0.108, and the zeta potential was -12.36 ± 3.58 mV. The results of MRI test confirmed that the PLA-PEG/Gd-DTPA nanocomplexes possessed the ability of MRI, and the direct correlation between the MRI imaging intensities and the nano-complex concentrations was observed ( r = 0.987). The signal intensity was still stable within 2 h after incubation of the nanocomplexes in human plasma. The nanocomplexes gave much better image contrast effects and longer stagnation time than that of commercial contrast agent in rat liver. A dose of 0.04 mmol of gadolinium per kilogram of body weight was sufficient to increase the MRI imaging intensities in rat livers by five-fold compared with the commercial Gd-DTPA. PLA-PEG/Gd-DTPA nanocomplexes could be prepared easily with small particle sizes. The nanocomplexes had high plasma stability, better image contrast effect, and liver targeting property. These results indicated that the PLA-PEG/Gd-DTPA nanocomplexes might be potential as molecular targeted imaging contrast agent.

  3. Biocompatible Nanocomplexes for Molecular Targeted MRI Contrast Agent

    Directory of Open Access Journals (Sweden)

    Yu Dexin

    2009-01-01

    Full Text Available Abstract Accurate diagnosis in early stage is vital for the treatment of Hepatocellular carcinoma. The aim of this study was to investigate the potential of poly lactic acid–polyethylene glycol/gadolinium–diethylenetriamine-pentaacetic acid (PLA–PEG/Gd–DTPA nanocomplexes using as biocompatible molecular magnetic resonance imaging (MRI contrast agent. The PLA–PEG/Gd–DTPA nanocomplexes were obtained using self-assembly nanotechnology by incubation of PLA–PEG nanoparticles and the commercial contrast agent, Gd–DTPA. The physicochemical properties of nanocomplexes were measured by atomic force microscopy and photon correlation spectroscopy. The T1-weighted MR images of the nanocomplexes were obtained in a 3.0 T clinical MR imager. The stability study was carried out in human plasma and the distribution in vivo was investigated in rats. The mean size of the PLA–PEG/Gd–DTPA nanocomplexes was 187.9 ± 2.30 nm, and the polydispersity index was 0.108, and the zeta potential was −12.36 ± 3.58 mV. The results of MRI test confirmed that the PLA–PEG/Gd–DTPA nanocomplexes possessed the ability of MRI, and the direct correlation between the MRI imaging intensities and the nano-complex concentrations was observed (r = 0.987. The signal intensity was still stable within 2 h after incubation of the nanocomplexes in human plasma. The nanocomplexes gave much better image contrast effects and longer stagnation time than that of commercial contrast agent in rat liver. A dose of 0.04 mmol of gadolinium per kilogram of body weight was sufficient to increase the MRI imaging intensities in rat livers by five-fold compared with the commercial Gd–DTPA. PLA–PEG/Gd–DTPA nanocomplexes could be prepared easily with small particle sizes. The nanocomplexes had high plasma stability, better image contrast effect, and liver targeting property. These results indicated that the PLA–PEG/Gd–DTPA nanocomplexes might be potential as molecular

  4. Element-specific spectral imaging of multiple contrast agents: a phantom study

    Science.gov (United States)

    Panta, R. K.; Bell, S. T.; Healy, J. L.; Aamir, R.; Bateman, C. J.; Moghiseh, M.; Butler, A. P. H.; Anderson, N. G.

    2018-02-01

    This work demonstrates the feasibility of simultaneous discrimination of multiple contrast agents based on their element-specific and energy-dependent X-ray attenuation properties using a pre-clinical photon-counting spectral CT. We used a photon-counting based pre-clinical spectral CT scanner with four energy thresholds to measure the X-ray attenuation properties of various concentrations of iodine (9, 18 and 36 mg/ml), gadolinium (2, 4 and 8 mg/ml) and gold (2, 4 and 8 mg/ml) based contrast agents, calcium chloride (140 and 280 mg/ml) and water. We evaluated the spectral imaging performances of different energy threshold schemes between 25 to 82 keV at 118 kVp, based on K-factor and signal-to-noise ratio and ranked them. K-factor was defined as the X-ray attenuation in the K-edge containing energy range divided by the X-ray attenuation in the preceding energy range, expressed as a percentage. We evaluated the effectiveness of the optimised energy selection to discriminate all three contrast agents in a phantom of 33 mm diameter. A photon-counting spectral CT using four energy thresholds of 27, 33, 49 and 81 keV at 118 kVp simultaneously discriminated three contrast agents based on iodine, gadolinium and gold at various concentrations using their K-edge and energy-dependent X-ray attenuation features in a single scan. A ranking method to evaluate spectral imaging performance enabled energy thresholds to be optimised to discriminate iodine, gadolinium and gold contrast agents in a single spectral CT scan. Simultaneous discrimination of multiple contrast agents in a single scan is likely to open up new possibilities of improving the accuracy of disease diagnosis by simultaneously imaging multiple bio-markers each labelled with a nano-contrast agent.

  5. Ultrasound-induced Gas Release from Contrast Agent Microbubbles

    NARCIS (Netherlands)

    Postema, M.A.B.; Postema, Michiel; Bouakaz, Ayache; Versluis, Michel; de Jong, N.

    2005-01-01

    We investigated gas release from two hard-shelled ultrasound contrast agents by subjecting them to high-mechanical index (MI) ultrasound and simultaneously capturing high-speed photographs. At an insonifying frequency of 1.7 MHz, a larger percentage of contrast bubbles is seen to crack than at 0.5

  6. Analytical interference by contrast agents in biochemical assays

    DEFF Research Database (Denmark)

    Otnes, Sigrid; Fogh-Andersen, Niels; Rømsing, Janne

    2017-01-01

    Objective. To provide a clinically relevant overview of the analytical interference by contrast agents (CA) in laboratory blood test measurements. Materials and Methods. The effects of five CAs, gadobutrol, gadoterate meglumine, gadoxetate disodium, iodixanol, and iomeprol, were studied on the 29...... most frequently performed biochemical assays. One-day-old plasma, serum, and whole blood were spiked with doses of each agent such that the gadolinium agents and the iodine agents reached concentrations of 0.5mMand 12mg iodine/mL, respectively. Subsequently, 12 assays were reexamined using 1/2 and 1...

  7. Process for preparation of MR contrast agents

    DEFF Research Database (Denmark)

    2002-01-01

    The present invention provides a process for the preparation of an MR contrast agent, said process comprising: i) obtaining a solution in a solvent of a hydrogenatable, unsaturated substrate compound and a catalyst for the hydrogenation of said substrate compound; ii) introducing said solution...... in droplet form into a chamber containing hydrogen gas (H2) enriched in para-hydrogen (p-1H2) and/or ortho-deuterium (o-2H2) whereby to hydrogenate said substrate to form a hydrogenated imaging agent; iii) optionally subjecting said hydrogenated imaging agent to a magnetic field having a field strength below...... earth's ambient field strength; iv) optionally dissolving said imaging agent in an aqueous medium; v) optionally separating said catalyst from the solution of said imaging agent in said aqueous medium; vi) optionally separating said solvent from the solution of said imaging agent in said aqueous medium...

  8. A biomarker-responsive T2ex MRI contrast agent.

    Science.gov (United States)

    Daryaei, Iman; Randtke, Edward A; Pagel, Mark D

    2017-04-01

    This study investigated a fundamentally new type of responsive MRI contrast agent for molecular imaging that alters T 2 exchange (T 2ex ) properties after interacting with a molecular biomarker. The contrast agent Tm-DO3A-oAA was treated with nitric oxide (NO) and O 2 . The R 1 and R 2 relaxation rates of the reactant and product were measured with respect to concentration, temperature, and pH. Chemical exchange saturation transfer (CEST) spectra of the reactant and product were acquired using a 7 Tesla (T) MRI scanner and analyzed to estimate the chemical exchange rates and r 2ex relaxivities. The reaction of Tm-DO3A-oAA with NO and O 2 caused a 6.4-fold increase in the r 2 relaxivity of the agent, whereas r 1 relaxivity remained unchanged, which demonstrated that Tm-DO3A-oAA is a responsive T 2ex agent. The effects of pH and temperature on the r 2 relaxivities of the reactant and product supported the conclusion that the product's benzimidazole ligand caused the agent to have a fast chemical exchange rate relative to the slow exchange rate of the reactant's ortho-aminoanilide ligand. T 2ex MRI contrast agents are a new type of responsive agent that have good detection sensitivity and specificity for detecting a biomarker, which can serve as a new tool for molecular imaging. Magn Reson Med 77:1665-1670, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  9. Enhanced conjugation stability and blood circulation time of macromolecular gadolinium-DTPA contrast agent.

    Science.gov (United States)

    Jenjob, Ratchapol; Kun, Na; Ghee, Jung Yeon; Shen, Zheyu; Wu, Xiaoxia; Cho, Steve K; Lee, Don Haeng; Yang, Su-Geun

    2016-04-01

    In this study, we prepared macromolecular MR T1 contrast agent: pullulan-conjugated Gd diethylene triamine pentaacetate (Gd-DTPA-Pullulan) and estimated residual free Gd(3+), chelation stability in competition with metal ions, plasma and tissue pharmacokinetics, and abdominal MR contrast on rats. Residual free Gd(3+) in Gd-DTPA-Pullulan was measured using colorimetric spectroscopy. The transmetalation of Gd(3+) incubated with Ca(2+) was performed by using a dialysis membrane (MWCO 100-500 Da) and investigated by ICP-OES. The plasma concentration profiles of Gd-DTPA-Pullulan were estimated after intravenous injection at a dose 0.1 mmol/kg of Gd. The coronal-plane abdominal images of normal rats were observed by MR imaging. The content of free Gd(3+), the toxic residual form, was less than 0.01%. Chelation stability of Gd-DTPA-Pullulan was estimated, and only 0.2% and 0.00045% of Gd(3+) were released from Gd-DTPA-Pullulan after 2h incubation with Ca(2+) and Fe(2+), respectively. Gd-DTPA-Pullulan displayed the extended plasma half-life (t1/2,α=0.43 h, t1/2,β=2.32 h), much longer than 0.11h and 0.79 h of Gd-EOB-DTPA. Abdominal MR imaging showed Gd-DTPA-Pullulan maintained initial MR contrast for 30 min. The extended plasma half-life of Gd-DTPA-Pullulan probably allows the prolonged MR acquisition time in clinic with enhanced MR contrast. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. State and development of new clinical contrast agents for MR diagnosis of liver diseases

    International Nuclear Information System (INIS)

    Rummeny, E.J.; Peters, P.E.

    1992-01-01

    MR contrast agents are developed for pharmaceutical manipulation of tissue signal intensities. Today it is widely recognized that MR contrast agents will play an increasingly important role in MR imaging of the liver. Contrast-enhanced MR-imaging allows to obtain simultaneously dynamic physiologic information and high anatomci detail. Up to now three major classes of MR contrast agents are available for clinical MR-imaging of the liver. These include paramagnetic perfusion agents, hepatobiliary agents, and superparamagnetic RES-specific iron oxide particles. A fourth class of contrast agents now in use for animal experiments includes ultrasmall superparamagnetic particles which can be targeted to extrareticuloendothelial structures such as asialoglycoprotein receptors of hepatocytes. In this article, we review recent advances in the development of MR contrast media and the clinical of contrast-enhanced MR imaging of the liver. (orig.) [de

  11. Perfusion imaging with magnetic-susceptibility contrast media

    International Nuclear Information System (INIS)

    Rosen, B.R.; Belliveau, J.W.; Betteridge, D.; Cohen, M.S.; Weisskoff, R.M.; Vevea, J.M.; Rzedzian, R.P.; Brady, T.J.

    1989-01-01

    In animal models, transient signal los on T2-weighted images has been well documented following intravenous injection of high-magnetic-susceptibility contrast agents that are compartmentalized within the brain intravascular space. These signal changes have been correlated with physiologic parameters, such as blood flow and volume. The advent of whole-body single-shot imaging capability, coupled with the approval of paramagnetic contrasts agents for human use, has enabled the authors to demonstrate susceptibility contrast in the human brain, allowing for generation of functional images. With use of a 1.5-T imaging system gradient-echo images (TE = 60 msec) were acquired in 75 msec. Sequential single-sections images were sampled every 1 second following bolus administration of 0.1 mmol/kg of Gd-DTPA

  12. The advantage of high relaxivity contrast agents in brain perfusion

    International Nuclear Information System (INIS)

    Cotton, F.; Hermier, M.

    2006-01-01

    Accurate MRI characterization of brain lesions is critical for planning therapeutic strategy, assessing prognosis and monitoring response to therapy. Conventional MRI with gadolinium-based contrast agents is useful for the evaluation of brain lesions, but this approach primarily depicts areas of disruption of the blood-brain barrier (BBB) rather than tissue perfusion. Advanced MR imaging techniques such as dynamic contrast agent-enhanced perfusion MRI provide physiological information that complements the anatomic data available from conventional MRI. We evaluated brain perfusion imaging with gadobenate dimeglumine (Gd-BOPTA, MultiHance; Bracco Imaging, Milan, Italy). The contrast-enhanced perfusion technique was performed on a Philips Intera 1.5-T MR system. The technique used to obtain perfusion images was dynamic susceptibility contrast-enhanced MRI, which is highly sensitive to T2* changes. Combined with PRESTO perfusion imaging, SENSE is applied to double the temporal resolution, thereby improving the signal intensity curve fit and, accordingly, the accuracy of the derived parametric images. MultiHance is the first gadolinium MR contrast agent with significantly higher T1 and T2 relaxivities than conventional MR contrast agents. The higher T1 relaxivity, and therefore better contrast-enhanced T1-weighted imaging, leads to significantly improved detection of BBB breakdown and hence improved brain tumor conspicuity and delineation. The higher T2 relaxivity allows high-quality T2*-weighted perfusion MRI and the derivation of good quality relative cerebral blood volume (rCBV) maps. We determined the value of MultiHance for enhanced T2*-weighted perfusion imaging of histologically proven (by surgery or stereotaxic biopsy) intraaxial brain tumors (n=80), multiple sclerosis lesions (n=10), abscesses (n=4), neurolupus (n=15) and stroke (n=16). All the procedures carried out were safe and no adverse events occurred. The acquired perfusion images were of good quality in

  13. Nanoparticles in magnetic resonance imaging: from simple to dual contrast agents

    Directory of Open Access Journals (Sweden)

    Estelrich J

    2015-03-01

    Full Text Available Joan Estelrich,1,2 María Jesús Sánchez-Martín,1 Maria Antònia Busquets1,2 1Departament de Fisicoquímica, Facultat de Farmàcia, Universitat de Barcelona, Barcelona, Catalonia, Spain; 2Institut de Nanociència I Nanotecnologia (IN2UB, Barcelona, Catalonia, SpainAbstract: Magnetic resonance imaging (MRI has become one of the most widely used and powerful tools for noninvasive clinical diagnosis owing to its high degree of soft tissue contrast, spatial resolution, and depth of penetration. MRI signal intensity is related to the relaxation times (T1, spin–lattice relaxation and T2, spin–spin relaxation of in vivo water protons. To increase contrast, various inorganic nanoparticles and complexes (the so-called contrast agents are administered prior to the scanning. Shortening T1 and T2 increases the corresponding relaxation rates, 1/T1 and 1/T2, producing hyperintense and hypointense signals respectively in shorter times. Moreover, the signal-to-noise ratio can be improved with the acquisition of a large number of measurements. The contrast agents used are generally based on either iron oxide nanoparticles or ferrites, providing negative contrast in T2-weighted images; or complexes of lanthanide metals (mostly containing gadolinium ions, providing positive contrast in T1-weighted images. Recently, lanthanide complexes have been immobilized in nanostructured materials in order to develop a new class of contrast agents with functions including blood-pool and organ (or tumor targeting. Meanwhile, to overcome the limitations of individual imaging modalities, multimodal imaging techniques have been developed. An important challenge is to design all-in-one contrast agents that can be detected by multimodal techniques. Magnetoliposomes are efficient multimodal contrast agents. They can simultaneously bear both kinds of contrast and can, furthermore, incorporate targeting ligands and chains of polyethylene glycol to enhance the accumulation of

  14. Computed tomography intravenous cholangiography

    International Nuclear Information System (INIS)

    Nascimento, S.; Murray, W.; Wilson, P.

    1997-01-01

    Indications for direct visualization of the bile ducts include bile duct dilatation demonstrated by ultrasound or computed tomography (CT) scanning, where the cause of the bile duct dilatation is uncertain or where the anatomy of bile duct obstruction needs further clarification. Another indication is right upper quadrant pain, particularly in a post-cholecystectomy patient, where choledocholithiasis is suspected. A possible new indication is pre-operative evaluation prior to laparoscopic cholecystectomy. The bile ducts are usually studied by endoscopic retrograde cholangiopancreatography (ERCP), or, less commonly, trans-hepatic cholangiography. The old technique of intravenous cholangiography has fallen into disrepute because of inconsistent bile-duct opacification. The advent of spiral CT scanning has renewed interest in intravenous cholangiography. The CT technique is very sensitive to the contrast agent in the bile ducts, and angiographic and three-dimensional reconstructions of the biliary tree can readily be obtained using the CT intravenous cholangiogram technique (CT IVC). Seven patients have been studied using this CT IVC technique, between February 1995 and June 1996, and are the subject of the present report. Eight further studies have since been performed. The results suggest that CT IVC could replace ERCP as the primary means of direct cholangiography, where pancreatic duct visualization is not required. (authors)

  15. Gadolinium-porphyrins: new potential magnetic resonance imaging contrast agents for melanoma detection

    Directory of Open Access Journals (Sweden)

    Daryoush Shahbazi-Gahrouei

    2006-11-01

    Full Text Available BACKGROUND: Two new porphyrin-based magnetic resonance imaging (MRI contrast agents, Gd-hematoporphyrin (Gd-H and Gd-tetra-carboranylmethoxyphenyl-porphyrin (Gd-TCP were synthesized and tested in nude mice with human melanoma (MM-138 xenografts as new melanoma contrast agents. METHODS: Subcutaneous xenografts of human melanoma cells (MM-138 were studied in 30 (five groups of six nude mice. The effect of different contrast agents (Gd-TCP, Gd-H, GdCl3 and Gd-DTPA on proton relaxation times was measured in tumors and other organs. T1 values, signal enhancement and the Gd concentration for different contrast agent solutions were also investigated. RESULTS: The porphyrin agents showed higher relaxivity compared to the clincal agent, Gd-DTPA. A significant 16% and 21% modification in T1 relaxation time of the water in human melanoma tumors grafted in the nude mice was revealed 24 hours after injection of Gd-TCP and Gd-H, respectively. The percentage of injected Gd localized to the tumor measured by inductively coupled plasma atomic emission spectrometry (ICP-AES was approximately 21% for Gd-TCP and 28% for Gd-H which were higher than that of Gd-DTPA (10%. CONCLUSIONS: The high concentration of Gd in the tumor is indicative of a selective retention of the compounds and indicates that Gd-TCP and Gd-H are promising MR imaging contrast agents for melanoma detection. Gd-porphyrins have considerable promise for further diagnostic applications in magnetic resonance imaging. KEY WORDS: MRI, porphyrin-based contrast agent, hematoporphyrin, melanoma.

  16. 10% low density corn-oil emulsion oral contrast agent for abdominal computed tomography

    International Nuclear Information System (INIS)

    Choi, Sun Kyou; Chon, Dong Kwon; Han, Young Min; Kim, Chong Soo; Sohn, Myung Hee; Song, Ho Young; Choi, Ki Chul

    1990-01-01

    CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% COE is superior to that receiving oral contrast agent. 3. The discrimination between pancreatic head from duodenal C-loop is better in patients receiving 10% COE than in patients receiving conventional oral contrast agent. 4. In patients receiving 10% COE, differentiation of cystic masses from intestinal loops is sometimes difficult. The results of this study indicate that 10% COE may be useful oral contrast agent for optimal visualization of gastric mucosa and pancreatico-duodenal discrimination on abdominal CT

  17. Development of organic MRI contrast agents

    International Nuclear Information System (INIS)

    Hayashi, Hiroyuki; Sato, Yuichiro; Karasawa, Satoru; Koga, Noboru

    2008-01-01

    Described are trends of the development in the title since those agents with target properties are awaited for specific organ and regional MRI. The contrast agents alter the relaxation time of water proton to yield the enhanced contrast between organs and tissues with different water volumes. Nowadays Gd-complexes and nano-particle of superparamagnetic iron oxide (Fe(III)) are widely used for enhancing in clinic. Among organic compounds with paramagnetic spin, those possessing nitroxide radical like TEMPO- and PROXYL-radicals have been subject to development by their derivatization. High spin molecules conceivably affect the relaxivity, which, however, is found smaller per spin of synthesized triplet complexes than doublet ones. This has lead to basic approach for molecules restricting water movement due to their hydrogen bond like DNA as a model, for introducing many radicals in high molecular weight compounds, and their polymer, as one of which authors have developed a derivative of hyperbranched polymer (HPS)-TEMPO having the similar relaxivity to gadolinium-diethylenetiamine pentaacetid acid (Gd-DTPA) (R.T.)

  18. MRI and CT contrast media extravasation: A systematic review.

    Science.gov (United States)

    Heshmatzadeh Behzadi, Ashkan; Farooq, Zerwa; Newhouse, Jeffery H; Prince, Martin R

    2018-03-01

    This systematic review combines data from multiple papers on contrast media extravasation to identify factors contributing to increased extravasation risk. Data were extracted from 17 papers reporting 2191 extravasations in 1,104,872 patients (0.2%) undergoing computed tomography (CT) or magnetic resonance imaging (MRI). Extravasation rates were 0.045% for gadolinium-based contrast agents (GBCA) and nearly 6-fold higher, 0.26% for iodinated contrast agents. Factors associated with increased contrast media extravasations included: older age, female gender, using an existing intravenous (IV) instead of placing a new IV in radiology, in-patient status, use of automated power injection, high injection rates, catheter location, and failing to warm up the more viscous contrast media to body temperature. Contrast media extravasation is infrequent but nearly 6 times less frequent with GBCA for MRI compared with iodinated contrast used in CT.

  19. Evaluation of potential gastrointestinal contrast agents for echoplanar MR imaging

    International Nuclear Information System (INIS)

    Reimer, P.; Schmitt, F.; Ladebeck, R.; Graessner, J.; Schaffer, B.

    1993-01-01

    The purpose of this study was to investigate approved aqueous gastrointestinal contrast agents for use in abdominal EPI. Conventional and echoplanar MR imaging experiments were performed with 1.0 Tesla whole body systems. Phantom measurements of Gastrografin, barium sulfate suspension, oral gadopentetate dimeglumine, water, and saline were performed. Signal intensity (SI) of aqueous oral barium sulfate and iodine based CT contrast agents was lower on conventional spin-echo (SE), Flash, and Turbo-Flush images than on EP images. The contrast agents exhibited higher SI on T2-weighted SE PE images and TI-time dependence on inversion recovery EP-images. The barium sulfate suspension was administered in volunteers to obtain information about bowel lumen enhancement and susceptibility artifacts. Oral administration of the aqueous barium sulfate suspension increased bowel lumen signal and reduced susceptibility artifacts. (orig.)

  20. Contrast enhanced MRA: do contrast agents with a higher T1 relaxitivity improve the visualization of carotid artery stenoses?

    International Nuclear Information System (INIS)

    Friese, S.; Krapf, H.; Skalej, M.; Kueker, W.; Fetter, M.; Vonthein, R.

    2001-01-01

    CE-MRA is a powerful tool for the non-invasive evaluation of carotid artery occlusive disease. However, due to certain drawbacks, it has not completely replaced DSA. The purpose of this study was to evaluate if Gd-BOPTA, a contrast agent with high T 1 relaxivity, can increase the diagnostic accuracy of CE-MRA. Material and Methods: The CE-MRA examinations of 54 consecutive patients were evaluated by two experienced radiologists, independently. The examinations of 27 patients were contrasted either with 20 ml Gd-BOPTA or with 20 ml Gd-DTPA. The reviewers were blinded to the contrast agent chosen and to the ultrasound results. They rated the overall image quality and the degree of the ICA stenoses. Results: For the estimation of the degree of the ICA stenoses there was a high interrater validity. In comparison to the ultrasound findings, 6 of 50 high-degree stenoses were underestimated as moderate stenoses. In one of seven sonographically occluded vessels, MRA revealed residual patency in the vessel lumen. It was not possible to identify the contrast agent that was taken for a study. Subjective estimation of the image quality (arterial contrast of the ICA, contrast of the other vessels, and general impression) did not significantly change with the contrast agent employed. Conclusion: The diagnostic accuracy of CE-MRA for the evaluation of internal carotid artery stenoses is not improved by Gd-BOPTA if identical volumina of contrast media are applied. The potential of this contrast agent can be the reduction of the amount of contrast without loss of diagnostic information. Further studies are necessary. (orig.) [de

  1. Novel Gd nanoparticles enhance vascular contrast for high-resolution magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Tot Bui

    2010-09-01

    Full Text Available Gadolinium (Gd, with its 7 unpaired electrons in 4f orbitals that provide a very large magnetic moment, is proven to be among the best agents for contrast enhanced MRI. Unfortunately, the most potent MR contrast agent based on Gd requires relatively high doses of Gd. The Gd-chelated to diethylene-triamine-penta-acetic acid (DTPA, or other derivatives (at 0.1 mmole/kg recommended dose, distribute broadly into tissues and clear through the kidney. These contrast agents carry the risk of Nephrogenic Systemic Fibrosis (NSF, particularly in kidney impaired subjects. Thus, Gd contrast agents that produce higher resolution images using a much lower Gd dose could address both imaging sensitivity and Gd safety.To determine whether a biocompatible lipid nanoparticle with surface bound Gd can improve MRI contrast sensitivity, we constructed Gd-lipid nanoparticles (Gd-LNP containing lipid bound DTPA and Gd. The Gd-LNP were intravenously administered to rats and MR images collected. We found that Gd in Gd-LNP produced a greater than 33-fold higher longitudinal (T(1 relaxivity, r(1, constant than the current FDA approved Gd-chelated contrast agents. Intravenous administration of these Gd-LNP at only 3% of the recommended clinical Gd dose produced MRI signal-to-noise ratios of greater than 300 in all vasculatures. Unlike current Gd contrast agents, these Gd-LNP stably retained Gd in normal vasculature, and are eliminated predominately through the biliary, instead of the renal system. Gd-LNP did not appear to accumulate in the liver or kidney, and was eliminated completely within 24 hrs.The novel Gd-nanoparticles provide high quality contrast enhanced vascular MRI at 97% reduced dose of Gd and do not rely on renal clearance. This new agent is likely to be suitable for patients exhibiting varying degrees of renal impairment. The simple and adaptive nanoparticle design could accommodate ligand or receptor coating for drug delivery optimization and in vivo drug

  2. Cardiac image segmentation for contrast agent videodensitometry

    NARCIS (Netherlands)

    Mischi, M.; Kalker, A.A.C.M.; Korsten, H.H.M.

    2005-01-01

    Indicator dilution techniques are widely used in the intensive care unit and operating room for cardiac parameter measurements. However, the invasiveness of current techniques represents a limitation for their clinical use. The development of stable ultrasound contrast agents allows new applications

  3. Advanced detection strategies for ultrasound contrast agents

    NARCIS (Netherlands)

    J.M.G. Borsboom (Jerome)

    2005-01-01

    markdownabstract__Abstract__ Ultrasound contrast agent was discovered serendipitously by Gramiak and Shah in I968 when they injected indocyanine green dye into the heart and observed increased echogenicity of the blood containing the dye. Small cavitation bubbles that were formed upon

  4. The histopathologic reaction of rabbit lungs after intrabronchial application of contrast agents

    International Nuclear Information System (INIS)

    Lim, Hyo Soon; Kim, Jae Kyu; Shen, Yu Lan; Oh, Jeong Won; Chang, Nam Kyu; Shin, Sang Soo; Park, Jin Gyoon; Kang, Heoung Keun

    2006-01-01

    The aim of this study was to determine a safe gastrointestinal contrast agent that could be used in various clinical situations where there is a risk of aspiration using a rabbit model. 30 healthy white rabbits were used. The rabbits were divided into 5 groups containing six animals each, one control group (anesthesia only) and 4 groups receiving various contrast agents [Solotop (Barium sulphate suspension), Gastrografin (sodium and meglumine amidotrizoate), and Telebrix (Meglumine ioxitalamate), Visipaque (Iodixanol)]. The contrast agents were injected selectively into a main bronchus via a catheter inserted under fluoroscopy guidance. The rabbits were sacrificed either 1 day or 7 days after injecting the contrast agents, and the tissue reaction of the bronchi and lungs were examined both macro-and microscopically. The level of alveolar septal thickening, peribronchiolar lymphocytic infiltration, pulmonary congestion and edema, inflammatory exudate in the alveoli or bronchiolar lumina, microabscess formation, necrosis, pigmentation of materials injected, and fibropurulent pleurisy were evaluated and graded according to the severity as follows: no change, mild, moderate, marked in degree. The common microscopic findings were alveolar septal thickening and peribronchiolar lymphocytic infiltration. Pulmonary congestion and edema, inflammatory exudate in the alveoli of bronchiolar lumina were observed in 21 out of 24 rabbits receiving the contrast agents. Pigmentation of the materials injected was observed only in the group receiving Solotop. An inflammatory exudate in the alveoli and bronchiolar/bronchial lumina, microabscess formation, and necrosis were noted in most groups, but was more frequent and severe in the group receiving Gastrografin. The histopathological reactions of the rabbit lungs after the intrabronchial application of a contrast agent showed variable degrees of inflammatory reaction. Gastrografin produced most severe and extensive reaction, Solotop

  5. Safe Use of Contrast Media: What the Radiologist Needs to Know.

    Science.gov (United States)

    Beckett, Katrina R; Moriarity, Andrew K; Langer, Jessica M

    2015-10-01

    Iodinated and gadolinium-based contrast media are used on a daily basis in most radiology practices. These agents often are essential to providing accurate diagnoses, and are nearly always safe and effective when administered correctly. However, reactions to contrast media do occur and can be life threatening. Therefore, it is critical for faculty and staff to know how reactions to contrast agents manifest and how to treat them promptly. The decline in renal function seen occasionally after intravenous administration of iodinated contrast agents is poorly understood and likely multifactorial, and its association with the contrast medium may be overemphasized. However, it is important that radiologists be aware of current understanding and strategies to decrease the incidence of renal dysfunction. Nephrogenic systemic fibrosis, a skin disease, is an adverse reaction related to use of some gadolinium-based contrast agents in patients with chronic renal failure. The types of gadolinium most often associated with this condition and the indications for withholding gadolinium are important and are discussed in this article. The use of enteric contrast agents and contrast agents during pregnancy and nursing are reviewed briefly. Current knowledge for safe use of contrast media and key concepts that all radiologists should know are summarized in this review. © RSNA, 2015.

  6. Retrospective analysis of non-laboratory-based adverse drug reactions induced by intravenous radiocontrast agents in a Joint Commission International-accredited academic medical center hospital in China

    Directory of Open Access Journals (Sweden)

    Chen QL

    2017-04-01

    Full Text Available Qin-lan Chen,1 Xiao-ying Zhao,2 Xiao-mi Wang,1 Na Lv,2 Ling-ling Zhu,3 Hui-min Xu,4 Quan Zhou4 1Radiology Nursing Unit, Division of Nursing, 2Department of Quality Management, 3Geriatric VIP Care Ward, Division of Nursing, 4Department of Pharmacy, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, People’s Republic of China Abstract: The authors retrospectively analyzed the pattern and characteristics of non-laboratory-based adverse drug reactions (ADRs induced by intravenous radiocontrast agents in a large-scale hospital in China during 2014–2015. There were 314 ADR cases among 118,208 patients receiving enhanced CT or MRI examinations. The frequency of moderate/severe ADRs defined by Chinese Society of Radiology (ie, severe vomiting, systematic urticaria, facial swelling, dyspnea, vasovagal reaction, laryngeal edema, seizure, trembling, convulsions, unconsciousness, shock, death, and other unexpected adverse reactions was rare (0.0431%, whereas the mild ADRs were uncommon (0.2225% and accounted for 83.76% of ADRs. Frequency of ADRs induced by iodinated contrast agents was related with examination site, sex, and type of patient settings (P<0.01 and was higher compared with gadolinium contrast agents (0.3676% vs 0.0504%, P<0.01. From 2014 to 2015, frequencies of total and moderate/severe ADRs induced by iodinated contrast agents decreased significantly (0.4410% vs 0.2947%, P<0.01; 0.0960% vs 0.0282%, P<0.01, respectively. Frequency of ADRs differed among different iodinated contrast and gadolinium contrast (P<0.05 agents. Iopromide’s ADR frequency in 2014 was significantly higher compared with iopamidol, ioversol, or iohexol (P<0.01. Frequency of moderate/severe ADRs induced by iodixanol was 4.1–5.4 times that of iohexol, iopromide, or iopamidol. Rash was the predominant ADR subtype (84.39% and occurred more frequently with iodixanol compared with iohexol, iopamidol, or ioversol (P<0

  7. Design and Optimization of Gadolinium Based Contrast Agents for Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Pereira, G.A.; Geraldes, C.F.G.C.; University of Coimbra

    2007-01-01

    The role of Gd 3+ chelates as contrast agents in Magnetic Resonance Imaging is discussed. The theory describing the different contributions to paramagnetic relaxation relevant to the understanding of the molecular parameters determining the relativity of those Gd 3+ chelates, is presented. The experimental techniques used to obtain those parameters are also described. Then, the various approaches taken to optimize those parameters, leading to maximum relativity (efficiency) of the contrast agents, are also illustrated with relevant examples taken from the literature. The various types of Gd 3+ -based agents, besides non-specific and hepatobiliary agents, are also discussed, namely blood pool, targeting, responsive and paramagnetic chemical shift saturation transfer (PARACEST) agents. Finally, a perspective is presented of some of the challenges lying ahead in the optimization of MRI contrast agents to be useful in Molecular Imaging. (author)

  8. Dual-contrast agent photon-counting computed tomography of the heart: initial experience.

    Science.gov (United States)

    Symons, Rolf; Cork, Tyler E; Lakshmanan, Manu N; Evers, Robert; Davies-Venn, Cynthia; Rice, Kelly A; Thomas, Marvin L; Liu, Chia-Ying; Kappler, Steffen; Ulzheimer, Stefan; Sandfort, Veit; Bluemke, David A; Pourmorteza, Amir

    2017-08-01

    To determine the feasibility of dual-contrast agent imaging of the heart using photon-counting detector (PCD) computed tomography (CT) to simultaneously assess both first-pass and late enhancement of the myocardium. An occlusion-reperfusion canine model of myocardial infarction was used. Gadolinium-based contrast was injected 10 min prior to PCD CT. Iodinated contrast was infused immediately prior to PCD CT, thus capturing late gadolinium enhancement as well as first-pass iodine enhancement. Gadolinium and iodine maps were calculated using a linear material decomposition technique and compared to single-energy (conventional) images. PCD images were compared to in vivo and ex vivo magnetic resonance imaging (MRI) and histology. For infarct versus remote myocardium, contrast-to-noise ratio (CNR) was maximal on late enhancement gadolinium maps (CNR 9.0 ± 0.8, 6.6 ± 0.7, and 0.4 ± 0.4, p contrast agent cardiac imaging is feasible with photon-counting detector CT. These initial proof-of-concept results may provide incentives to develop new k-edge contrast agents, to investigate possible interactions between multiple simultaneously administered contrast agents, and to ultimately bring them to clinical practice.

  9. Ultrasmall cationic superparamagnetic iron oxide nanoparticles as nontoxic and efficient MRI contrast agent and magnetic-targeting tool

    Directory of Open Access Journals (Sweden)

    Uchiyama MK

    2015-07-01

    Full Text Available Mayara Klimuk Uchiyama,1 Sergio Hiroshi Toma,1 Stephen Fernandes de Paula Rodrigues,2 Ana Lucia Borges Shimada,2 Rodrigo Azevedo Loiola,2 Hernán Joel Cervantes Rodríguez,3 Pedro Vitoriano Oliveira,4 Maciel Santos Luz,4 Said Rahnamaye Rabbani,3 Henrique Eisi Toma,1 Sandra Helena Poliselli Farsky,2 Koiti Araki11Laboratory of Supramolecular Chemistry and Nanotechnology, Department of Fundamental Chemistry, Institute of Chemistry, 2Laboratory of Experimental Toxicology, Department of Clinical and Toxicological Analysis, Faculty of Pharmaceutical Sciences, 3Magnetic Resonance Laboratory, Department of General Physics, Institute of Physics, 4Analysis and Research Group in Spectrometry, Department of Fundamental Chemistry, Institute of Chemistry, University of Sao Paulo, Sao Paulo, SP, BrazilAbstract: Fully dispersible, cationic ultrasmall (7 nm diameter superparamagnetic iron oxide nanoparticles, exhibiting high relaxivity (178 mM-1s-1 in 0.47 T and no acute or subchronic toxicity in Wistar rats, were studied and their suitability as contrast agents for magnetic resonance imaging and material for development of new diagnostic and treatment tools demonstrated. After intravenous injection (10 mg/kg body weight, they circulated throughout the vascular system causing no microhemorrhage or thrombus, neither inflammatory processes at the mesentery vascular bed and hepatic sinusoids (leukocyte rolling, adhesion, or migration as evaluated by intravital microscopy, but having been spontaneously concentrated in the liver, spleen, and kidneys, they caused strong negative contrast. The nanoparticles are cleared from kidneys and bladder in few days, whereas the complete elimination from liver and spleen occurred only after 4 weeks. Ex vivo studies demonstrated that cationic ultrasmall superparamagnetic iron oxide nanoparticles caused no effects on hepatic and renal enzymes dosage as well as on leukocyte count. In addition, they were readily concentrated in rat

  10. Modified natural nanoparticles as contrast agents for medical imaging

    NARCIS (Netherlands)

    Cormode, David P.; Jarzyna, Peter A.; Mulder, Willem J. M.; Fayad, Zahi A.

    2010-01-01

    The development of novel and effective contrast agents is one of the drivers of the ongoing improvement in medical imaging. Many of the new agents reported are nanoparticle-based. There are a variety of natural nanoparticles known, e.g. lipoproteins, viruses or ferritin. Natural nanoparticles have

  11. [Development of Biliary Contrast Agents Remote Pushing Device].

    Science.gov (United States)

    Zhu, Haoyang; Dong, Dinghui; Luo, Yu; Ren, Fenggang; Zhang, Jing; Tan, Wenjun; Shi, Aihua; Hu, Liangshuo; Wu, Rongqian; Lyu, Yi

    2018-01-30

    A biliary contrast agents pushing device, including a syringe pushing system and a remote controller is introduced. The syringe pushing system comprises an injector card slot, a support platform and an injection bolus fader. A 20 mL syringe can be fitted on the syringe pushing system and kept with the ground about 30 degree. This system can perform air bubble pumping back and contrast agents bolus injection as well as speed adjustment. Remote controller is an infrared remote control which can start and stop the syringe pushing system. With this device, the remote controlled cholangiography technology can be achieved, which can not only protect doctors from X-ray radiation but also improve the traditional T-tube cholangiography and the contrast effect, reduce postoperative complications in patients as well. The application of this device will improve the current diagnosis and treatment system, the device will benefit the majority of doctors and patients.

  12. The effect of intravenous contrast on SUV value in 18F-FDG PET/CT using diagnostic high energy CT

    International Nuclear Information System (INIS)

    Jeong, Young Jin; Kang, Do Young

    2006-01-01

    According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT - 120 kVp, 130 mAs) scan. Than contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET emission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in all patients. Also pathologic lesions were investigated. There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p < 0.001). The maxSUV was 1.1 ± 0.5 in PET images with CECT-corrected attenuation and 1.0 ± 0.5 in PET images with NCCT-corrected attenuation. The limit of agreement was 0.1 ± 0.3 in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 and segment 8 of the liver and spleen (p <0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p < 0.001). The maxSUV was 4.7 ± 2.0 in PET images with CECT-corrected attenuation and 4.4 ± 2.0 in PET images with NCCT- corrected attenuation. The limit of agreement was 0.4 ± 0.8 in Bland-Altman analysis. Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of

  13. Contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Karadjian, V.

    1987-01-01

    The origine of nuclear magnetic resonance signal is reminded and different ways for contrast enhancement in magnetic resonance imaging are presented, especially, modifications of tissus relaxation times. Investigations have focused on development of agents incorporating either paramagnetic ions or stable free radicals. Pharmacological and toxicological aspects are developed. The diagnostic potential of these substances is illustrated by the example of gadolinium complexes [fr

  14. Contrast enhancement by lipid-based MRI contrast agents in mouse atherosclerotic plaques; a longitudinal study

    NARCIS (Netherlands)

    den Adel, Brigit; van der Graaf, Linda M.; Que, Ivo; Strijkers, Gustav J.; Löwik, Clemens W.; Poelmann, Robert E.; van der Weerd, Louise

    2013-01-01

    The use of contrast-enhanced MRI to enable in vivo specific characterization of atherosclerotic plaques is increasing. In this study the intrinsic ability of two differently sized gadolinium-based contrast agents to enhance atherosclerotic plaques in ApoE(-/-) mice was evaluated with MRI. We

  15. Nonspherical oscilllations of ultrasound contrast agent microbubbles

    NARCIS (Netherlands)

    Dollet, B.; van der Meer, S.M.; Garbin, V.; Garbin, Valeria; de Jong, N.; Lohse, Detlef; Versluis, Michel

    2008-01-01

    The occurrence of nonspherical oscillations (or surface modes) of coated microbubbles, used as ultrasound contrast agents in medical imaging, is investigated using ultra–high-speed optical imaging. Optical tweezers designed to micromanipulate single bubbles in 3-D are used to trap the bubbles far

  16. Contrast-enhanced CT with a High-Affinity Cationic Contrast Agent for Imaging ex Vivo Bovine, Intact ex Vivo Rabbit, and in Vivo Rabbit Cartilage

    OpenAIRE

    Stewart, Rachel C.; Bansal, Prashant N.; Entezari, Vahid; Lusic, Hrvoje; Nazarian, Rosalynn M.; Snyder, Brian D.; Grinstaff, Mark W.

    2013-01-01

    The high affinity of a cationic iodinated contrast agent for cartilage provides better tissue visualization, easier segmentation, higher contrast-to-noise ratios, and longer usable imaging windows and requires a lower dose of injected contrast agent compared with an anionic contrast agent.

  17. Ferrimagnetic ferritin cage nanoparticles used as MRI contrast agent

    Science.gov (United States)

    Cai, Y.; Cao, C.; Zhang, T.; Xu, H.; Pan, Y.

    2017-12-01

    The nano-sized ferrimagnetic ferritin cage nanoparticles are ideal materials for understanding of superparamagnetism, biomimetic synthesis of ultrafine magnetic particles and their application in biomedicine. Ferrimagnetic M-HFn nanoparticles with size of magnetite cores in a mean size ranges from 2.7 nm to 5.3 nm were synthesized through loading different amount of iron into recombinant human H chain ferritin (HFn) shells. Both the saturation magnetization (Ms) and blocking temperature (Tb) were increased with the size of ferrimagnetic cores. In essence, magnetic resonance imaging (MRI) analysis showed that the synthesized M-HFn nanoparticles (5.3 nm magnetite core) has extremely high transverse relaxivity (r2) values up to 320.9 mM-1S-1, which indicate that M-HFn nanoparticles are promising negative contrast agent in early detection of tumors. In addition, the longitudinal relaxivity (r1) (10.4 mM-1S-1) and r2/r1 ratio ( 2.2) of M-HFn nanoparticles ( 2.7 nm magnetite core in diameter) will make it a considerable potential as a positive contrast agent in MRI. This means the M-HFn nanoparticles can be used as dual functional MR contrast agent. Acute toxicity study of M-HFn in rats showed that a dosage of 20 mg Fe/kg makes no abnormalities by serum biochemical and hematological analysis as well as histopathological examination. Compared with a similar commercial contrast agent, combidex (with a clinical dosage of 2.7 mg Fe/kg), it indicates that M-HFn nanoparticle is of a relative safe ferrimagnetic nanoparticle when used in vivo.

  18. Chondromalacia of the knee: evaluation with a fat-suppression three-dimensional SPGR imaging after intravenous contrast injection.

    Science.gov (United States)

    Suh, J S; Cho, J H; Shin, K H; Kim, S J

    1996-01-01

    Twenty-one MRI studies with a fat-suppression three-dimensional spoiled gradient-recalled echo in a steady state (3D SPGR) pulse sequence after intravenous contrast injection were evaluated to assess the accuracy in depicting chondromalacia of the knee. On the basis of MR images, chondromalacia and its grade were determined in each of five articular cartilage regions (total, 105 regions) and then the results were compared to arthroscopic findings. The sensitivity, specificity, and accuracy of MRI were 70%, 99%, and 93%, respectively. MR images depicted 7 of 11 lesions of arthroscopic grade 1 or 2 chondromalacia, and seven of nine lesions of arthroscopic grade 3 or 4 chondromalacia. The cartilage abnormalities in all cases appeared as focal lesions with high signal intensity. Intravenous contrast-injection, fat-suppression 3D SPGR imaging showed high specificity in excluding cartilage abnormalities and may be considered as an alternative to intra-articular MR arthrography when chondromalacia is suspected.

  19. Synthetic Ni3S2/Ni hybrid architectures as potential contrast agents in MRI

    International Nuclear Information System (INIS)

    Ma, J; Chen, K

    2016-01-01

    Traditional magnetic resonance imaging (MRI) contrast agents mainly include superparamagnetic (SPM) iron oxide nanoparticle as T 2 contrast agent for liver and paramagnetic Gd (III)-chelate as T 1 contrast agent for all organs. In this work, weak ferromagnetic kale-like and SPM cabbage-like Ni 3 S 2 @Ni hybrid architectures were synthesized and evaluated as potential T 1 MRI contrast agents. Their relatively small r 2 /r 1 ratios of 2.59 and 2.38, and high r 1 values of 11.27 and 4.89 mmol −1 L s −1 (for the kale-like and cabbage-like Ni 3 S 2 @Ni, respectively) will shed some light on the development of new-type MRI contrast agents. (paper)

  20. Effect of Intravenous Administration of Contrast Media on Serum Creatinine Levels in Neonates.

    Science.gov (United States)

    Bedoya, Maria A; White, Ammie M; Edgar, J Christopher; Pradhan, Madhura; Raab, Elisabeth L; Meyer, James S

    2017-08-01

    Purpose To assess the effect of intravenous contrast media on renal function in neonates. Materials and Methods Institutional review board approval was obtained with waiver of consent. Electronic health records from January 2011 to April 2013 were reviewed retrospectively. Measures of renal function were obtained in inpatient neonates who underwent magnetic resonance (MR) imaging or computed tomography (CT) and for whom serum creatinine (Cr) levels were obtained within 72 hours before imaging and at least one time after imaging (>1 day after administration of contrast material). A total of 140 neonates who received contrast material (59 who underwent CT with iohexol or iodixanol and 81 who underwent MR imaging with gadopentetate dimeglumine) were identified. These neonates were frequency matched according to sex, gestational and postnatal age, and preimaging serum Cr levels with neonates who underwent unenhanced MR imaging or CT. Cr levels and glomerular filtration rates (GFRs) were grouped according to when they were obtained (before imaging, 1-2 days after imaging, 3-5 days after imaging, 6-9 days after imaging, 10-45 days after imaging, and more than 45 days after imaging). Serum Cr levels and GFRs for each time period were compared between groups by using hierarchic regressions or χ 2 or Fisher exact tests and with repeated-measures analysis of variance to compare groups on the rate of change in serum Cr levels and GFRs from before to after imaging. Results Cr levels decreased and GFRs increased in both groups from before to after imaging (CT group, P ≤ .01; MR imaging group, P ≤ .01). The neonates who underwent contrast material-enhanced imaging and the neonates who underwent unenhanced imaging showed similar serum Cr levels at all examined time periods. Groups also did not differ in the proportion of neonates with serum Cr levels higher than the reference range (>0.4 mg/dL) at any time point (iodine- [P > .12] or gadolinium-based [P > .13] contrast

  1. Double agents and secret agents: the emerging fields of exogenous chemical exchange saturation transfer and T2-exchange magnetic resonance imaging contrast agents for molecular imaging.

    Science.gov (United States)

    Daryaei, Iman; Pagel, Mark D

    2015-01-01

    Two relatively new types of exogenous magnetic resonance imaging contrast agents may provide greater impact for molecular imaging by providing greater specificity for detecting molecular imaging biomarkers. Exogenous chemical exchange saturation transfer (CEST) agents rely on the selective saturation of the magnetization of a proton on an agent, followed by chemical exchange of a proton from the agent to water. The selective detection of a biomarker-responsive CEST signal and an unresponsive CEST signal, followed by the ratiometric comparison of these signals, can improve biomarker specificity. We refer to this improvement as a "double-agent" approach to molecular imaging. Exogenous T 2 -exchange agents also rely on chemical exchange of protons between the agent and water, especially with an intermediate rate that lies between the slow exchange rates of CEST agents and the fast exchange rates of traditional T 1 and T 2 agents. Because of this intermediate exchange rate, these agents have been relatively unknown and have acted as "secret agents" in the contrast agent research field. This review exposes these secret agents and describes the merits of double agents through examples of exogenous agents that detect enzyme activity, nucleic acids and gene expression, metabolites, ions, redox state, temperature, and pH. Future directions are also provided for improving both types of contrast agents for improved molecular imaging and clinical translation. Therefore, this review provides an overview of two new types of exogenous contrast agents that are becoming useful tools within the armamentarium of molecular imaging.

  2. Intravenous administration of iodinated, non-ionic, low or isoosmolar contrast media: safety aspects; Intravenoese Anwendung von jodiertem, nichtionischem, nieder- bis isoosmolarem Kontrastmittel: Sicherheitsaspekte

    Energy Technology Data Exchange (ETDEWEB)

    Metz-Schimmerl, S.; Metz, V.; Schima, W.; Herold, C. [Universitaetsklinik fuer Radiodiagnostik und Ludwig Boltzmann-Institut fuer Klinische und Experimentelle Radiologie, Wien (Austria); Domanovits, H. [Universitaetsklinik fuer Notfallmedizin Wien, Wien (Austria)

    2002-01-01

    It iss the purpose of this review to provide information about the safe use of intravenously administered, iodinated, non-ionic, low or isoosmolar contrast media for radiological examinations, how to avoid adverse events, and how to react professionally in case of an anaphylactic reaction. Methods of prophylaxis and therapy for anaphylactic and chemotoxic effects of contrast media administration as well as absolute and relative contraindications are discussed. Medico-legal considerations of contrast agent administration, informed consent of patients, and methods of risk management for undesired contrast media reactions are considered in this article. Establishment of administration standards for contrast media is of tremendous importance to standardize radiological procedures. This basic radiological documentation is part of the institutional and individual legal safety management. (orig.) [German] Ziel dieses Artikels ist es, Kenntnisse zur sicheren Anwendung von intravenoes applizierten, jodierten, nichtionischen, nieder- bis isoosmolaren Roentgen-Kontrastmitteln zu vermitteln, um bei deren Verwendung unerwuenschte Wirkungen zu vermeiden oder im Falle eines anaphylaktischen Kontrastmittelzwischenfalls rasch und effektiv zu handeln. Neben Methoden der Verhuetung und Behandlung anaphylaktischer und chemotoxischer Wirkungen der Kontrastmittelgabe werden Einschraenkungen der Anwendung bei unterschiedlichen klinischen Bildern eroertert. Rechtliche Ueberlegungen zur Kontrastmittelanwendung, das Aufklaerungsgespraech und Praeventivmassnahmen zum Risiko-Management unerwuenschter Kontrastmittelwirkungen sind beruecksichtigt. Die Festlegung von Anwendungstandards fuer Kontrastmittel dient der Normierung medizinischen Vorgehens. Eine solche radiologische Basisdokumentation ist teil der institutionellen und individuellen rechtlichen Absicherung. (orig.)

  3. Red blood cell labeling with technetium-99m. Effect of radiopaque contrast agents

    International Nuclear Information System (INIS)

    Finkel, J.; Chervu, L.R.; Bernstein, R.G.; Srivastava, S.C.

    1988-01-01

    Radiographic contrast agents have been reported in the literature to interfere significantly with red blood cell (RBC) labeling in vivo by Tc-99m. Moreover, in the presence of contrast agents, red cells have been known to undergo significant morphologic changes. These observations led to the current RBC labeling study in patients (N = 25) undergoing procedures with the administration of contrast media. Before and after contrast administration, blood samples were drawn from each patient into vacutainer tubes containing heparin and RBC labeling was performed using 1-ml aliquots of these samples following the Brookhaven National Laboratory protocol. The differences in average percentage labeling yield with and without contrast media were not significant. In vivo labeling in hypertensive rats with administration of contrast media up to 600 mg likewise consistently gave high labeling yields at all concentrations. Purported alterations in cell labeling attributed to contrast agents are not reflected in these studies, and other pathophysiologic factors need to be identified to substantiate the previous reports. In vitro study offers a potentially useful and simple method to delineate effects of various agents on cell labeling

  4. Iron Oxide as an Mri Contrast Agent for Cell Tracking: Supplementary Issue

    Directory of Open Access Journals (Sweden)

    Daniel J. Korchinski

    2015-01-01

    Full Text Available Iron oxide contrast agents have been combined with magnetic resonance imaging for cell tracking. In this review, we discuss coating properties and provide an overview of ex vivo and in vivo labeling of different cell types, including stem cells, red blood cells, and monocytes/macrophages. Furthermore, we provide examples of applications of cell tracking with iron contrast agents in stroke, multiple sclerosis, cancer, arteriovenous malformations, and aortic and cerebral aneurysms. Attempts at quantifying iron oxide concentrations and other vascular properties are examined. We advise on designing studies using iron contrast agents including methods for validation.

  5. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery

    Directory of Open Access Journals (Sweden)

    Vera ePaefgen

    2015-09-01

    Full Text Available Ultrasound is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents. There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular contrast agents enable functional analyses, e.g. to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles’ shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by ultrasound pulses to locally release the entrapped agent. Recent studies show that ultrasound contrast agents are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of ultrasound contrast agents and introduces the current clinical applications of contrast-enhanced ultrasound. Additionally, an overview of the recent developments in ultrasound probe design for functional and molecular diagnosis as well as for drug delivery is given.

  6. Contrast agents provide a faster learning curve in dipyridamole stress echocardiography.

    Science.gov (United States)

    Zamorano, Jose; Sánchez, Violeta; Moreno, Raúl; Almería, Carlos; Rodrigo, Jose; Serra, Viviana; Azcona, Luis; Aubele, Adalia; Mataix, Luis; Sánchez-Harguindey, Luis

    2002-12-01

    Interobserver variability is an important limitation of the stress echocardiography and depends on the echocardiographer training. Our aim was to evaluate if the use of contrast agents during dipyridamole stress echocardiography would improve the agreement between an experienced and a non-experienced observer in stress echo and therefore if contrast would affect the learning period of dypyridamole stress echo. Two independent observers without knowledge of any patient data interpreted all stress studies. One observer was an experienced one and the other had experience in echocardiography but not in stress echo. Two observers analysed 87 non-selected and consecutive studies. Out of the 87 studies, 46 were performed without contrast administration, whereas i.v. contrast (2.5 g Levovist by two bolus at rest and at peak stress) was administered in 41. In all cases, second harmonic imaging and stress digitalisation pack was used. The agreement between observers showed a kappa index of 0.58 and 0.83 without and with contrast administration, respectively. The use of contrast agents provides a better agreement in the evaluation of stress echo between an experienced and a non-experienced observer in stress echo. Adding routinely contrast agents could probably reduce the number of exams required for the necessary learning curve in stress echocardiography.

  7. Gadolinium chloride as a contrast agent for imaging wood composite components by magnetic resonance

    Science.gov (United States)

    Thomas L. Eberhardt; Chi-Leung So; Andrea Protti; Po-Wah So

    2009-01-01

    Although paramagnetic contrast agents have an established track record in medical uses of magnetic resonance imaging (MRI), only recently has a contrast agent been used for enhancing MRI images of solid wood specimens. Expanding on this concept, wood veneers were treated with a gadolinium-based contrast agent and used in a model system comprising three-ply plywood...

  8. Immediate adverse reactions to intravenous iodinated contrast media in computed tomography Reacciones adversas inmediatas al contraste yodado intravenoso en tomografía computarizada Reações adversas imediatas ao contraste iodado intravenoso em tomografia computadorizada

    Directory of Open Access Journals (Sweden)

    Beatriz Cavalcanti Juchem

    2007-02-01

    Full Text Available This exploratory-descriptive, non-experimental quantitative research aimed to learn about immediate adverse reactions to intravenous iodinated contrast media in hospitalized patients submitted to computed tomography at a teaching hospital in the South of Brazil. During the study period, all adverse reactions showed mild intensity, at a frequency of 12.5% with ionic iodinated contrast media, and 1% with non-ionic contrast agent. The extravasation of contrast occurred in 2.2% of the injections in a peripheral vein without complications in any of the cases. The results are within the limits cited in international literature and suggest that tomography service professionals should know their own rates of adverse reactions to iodinated contrast agent, as well as the conditions in which they occur, in order to obtain evidence to evaluate the respective care delivery processes.Investigación cuantitativa del tipo exploratorio-descriptivo, de carácter no experimental. El objetivo consistía en conocer las reacciones adversas inmediatas al contraste yodado intravenoso en pacientes internados, sometidos a tomografía computarizada en un hospital escuela del sur de Brasil. Durante el período del estudio, todas las reacciones adversas tuvieron intensidad leve y una frecuencia del 12,5% con la utilización del contraste yodado iónico, y 1% con contraste no iónico. La extravasación del contraste ocurrió en un 2,2% de las inyecciones en vena periférica, no ocasionando complicaciones en ninguno de los casos. Los índices evidenciados en el presente estudio se mantuvieron dentro de los límites que constan en la revisión de literatura y, entre las recomendaciones, se sugiere que los servicios de tomografía conozcan los propios índices de reacciones adversas al contraste yodado y las condiciones en que ocurren, con la finalidad de obtener evidencias para evaluación de los respectivos procesos asistenciales.Pesquisa quantitativa, explorat

  9. Submicron polycaprolactone particles as a carrier for imaging contrast agent for in vitro applications.

    Science.gov (United States)

    Iqbal, Muhammad; Robin, Sophie; Humbert, Philippe; Viennet, Céline; Agusti, Geraldine; Fessi, Hatem; Elaissari, Abdelhamid

    2015-12-01

    Fluorescent materials have recently attracted considerable attention due to their unique properties and high performance as imaging agent in biomedical fields. Different imaging agents have been encapsulated in order to restrict its delivery to a specific area. In this study, a fluorescent contrast agent was encapsulated for in vitro application by polycaprolactone (PCL) polymer. The encapsulation was performed using modified double emulsion solvent evaporation technique with sonication. Fluorescent nanoparticles (20 nm) were incorporated in the inner aqueous phase of double emulsion. A number of samples were fabricated using different concentrations of fluorescent contrast agent. The contrast agent-containing submicron particle was characterized by a zetasizer for average particle size, SEM and TEM for morphology observations and fluorescence spectrophotometer for encapsulation efficiency. Moreover, contrast agent distribution in the PCL matrix was determined by confocal microscopy. The incorporation of contrast agent in different concentrations did not affect the physicochemical properties of PCL particles and the average size of encapsulated particles was found to be in the submicron range. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Synthesis and evaluation of nanoglobule-cystamine-(Gd-DO3A, a biodegradable nanosized magnetic resonance contrast agent for dynamic contrast-enhanced magnetic resonance urography

    Directory of Open Access Journals (Sweden)

    Rongzuo Xu

    2010-09-01

    Full Text Available Rongzuo Xu1, Todd Lyle Kaneshiro1, Eun-Kee Jeong2, Dennis L Parker2, Zheng-Rong Lu31Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, Salt Lake City, UT, USA; 2Department of Radiology, University of Utah, Salt Lake City, UT, USA; 3Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USAAbstract: Dynamic contrast-enhanced magnetic resonance imaging has been recently shown to be effective for diagnostic urography. High-resolution urographic images can be acquired with T1 contrast agents for the kidney and urinary tract with minimal noise in the abdomen. Currently, clinical contrast agents are low molecular weight agents and can rapidly extravasate from blood circulation, leading to slow contrast agent elimination through kidney and consequently providing limited contrast enhancement in urinary tract. In this study, a new biodegradable macromolecular contrast agent, nanoglobule-G4-cystamine-(Gd-DO3A, was prepared by conjugating Gd-DO3A chelates on the surface of a generation 4 nanoglobule, poly-l-lysine octa(3-aminopropylsilsesquioxane dendrimer, via a disulfide spacer, where the carrier had a precisely defined nanosize that is far smaller than the renal filtration threshold. The in vivo contrast enhancement and dynamic imaging of the urinary tract of the agent was evaluated in nude mice using a low molecular weight agent Gd(DTPA-BMA as a control. The agent eliminated rapidly from blood circulation and accumulated more abundantly in urinary tract than Gd(DTPA-BMA. The fast elimination kinetics is ideal for functional evaluation of the kidneys. The morphology of the kidneys and urinary tract was better visualized by the biodegradable nanoglobular contrast agent than Gd(DTPA-BMA. The agent also resulted in low liver contrast enhancement, indicating low nonspecific tissue deposition. These features render the G4 nanoglobule-cystamine-(Gd-DO3A conjugate a promising contrast agent for magnetic

  11. Contrast induced nephropathy in patients undergoing intravenous (IV) contrast enhanced computed tomography (CECT) and the relationship with risk factors: a meta-analysis.

    Science.gov (United States)

    Moos, Shira I; van Vemde, David N H; Stoker, Jaap; Bipat, Shandra

    2013-09-01

    To summarize the incidence of contrast-induced nephropathy (CIN) and associations between CIN incidence and risk factors in patients undergoing intravenous contrast-enhanced computed tomography (CECT) with low- or iso-osmolar iodinated contrast medium. This review is performed in accordance with the preferred reporting items in systematic reviews and meta-analysis (PRISMA) guidelines. We searched the MEDLINE, EMBASE and Cochrane databases from 2002 till November 2012. Two reviewers included papers and extracted data. The pooled data were analysed by either fixed or random-effects approach depending on heterogeneity defined as the I(2) index. 42 articles with 18,790 patients (mean age 61.5 years (range: 38-83 years)) were included. The mean baseline eGFR was 59.8 mL/min and ranged from 4 to 256 mL/min. Of all patients 45.0% had an estimated glomerular filtration rate (eGFR)65 years and use of non-steroidal anti-inflammatory drugs (NSAID's) with odds ratios of 1.73 (95%CI: 1.06-2.82), 1.87 (95%CI: 1.55-2.26), 1.79 (95%CI: 1.03-3.11), 1.95 (95%CI: 1.02-3.70) and 2.32 (95%CI: 1.04-5.19), respectively while hypertension, anaemia and CFH were not associated (p=0.13, p=0.38, p=0.40). The mean incidence of CIN after intravenous iodinated CECT was low and associated with renal insufficiency, diabetes, presence of malignancy, old age and NSAID's use. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. Photoacoustic imaging at 1064nm wavelength with exogenous contrast agents

    Science.gov (United States)

    Upputuri, Paul Kumar; Jiang, Yuyan; Pu, Kanyi; Pramanik, Manojit

    2018-02-01

    Photoacoustic (PA) imaging is a promising imaging modality for both preclinical research and clinical practices. Laser wavelengths in the first near infrared window (NIR-I, 650-950 nm) have been widely used for photoacoustic imaging. As compared with NIR-I window, scattering of photons by biological tissues is largely reduced in the second NIR (NIR-II) window, leading to enhanced imaging fidelity. However, the lack of biocompatible NIR-II absorbing exogenous agents prevented the use of this window for in vivo imaging. In recent years, few studies have been reported on photoacoustic imaging in NIR-II window using exogenous contrast agents. In this work, we discuss the recent work on PA imaging using 1064 nm wavelength, the fundamental of Nd:YAG laser, as an excitation wavelength. The PA imaging at 1064 nm is advantageous because of the low and homogeneous signal from tissue background, enabling high contrast in PA imaging when NIR-II absorbing contrast agents are employed.

  13. Low osmolar (non-ionic) contrast media versus high osmolar (ionic) contrast media in intravenous urography and enhanced computerized tomography: a cost-effectiveness analysis.

    Science.gov (United States)

    Wangsuphachart, S

    1991-12-01

    The cost-effectiveness of three alternative policies for the use of intravenous contrast media for urography and enhanced computerized tomography (CT) are analyzed. Alternative #1 is to use high osmolar contrast media (HOCM) in all patients, the historical policy. Alternative #2 is to replace it with low osmolar contrast media (LOCM) in all patients. Alternative #3 is to use LOCM only in the high risk patients. Data on the 6,242 patients who underwent intravenous urography and enhanced CT at the Department of Radiology, Chulalongkorn Hospital in 1989 were used. Both societal and hospital viewpoints were analyzed. The incremental cost-effectiveness (ICE) between #2 and #1 was 26,739 Baht (US$1,070) per healthy day saved (HDS), while the ICE between #3 and #1 was 12,057 Baht (US$482) per HDS. For fatal cases only, ICE between #2 and #1 was 35,111 Baht (US$1,404) per HDS, while the ICE between #3 and #1 was 18,266 Baht (US$731) per HDS. The incremental cost (IC) per patient was 2,341 Baht (US$94) and 681 Baht (US$27) respectively. For the hospital viewpoint the ICE between #2 and #1 was 13,744 (US$550) and between #3 and #1 was 6,127 Baht (US$245) per HDS. The IC per patient was 1,203 Baht (US$48) and 346 Baht (US$14), respectively. From the sensitivity analysis, #3 should be used if the LOCM price is reduced more than 75% (equal to 626 Baht or less) and more than 80% of the patients are able to pay for the contrast media.

  14. Comparison of differently viscous iodinated and bariumcontaining contrast agents in the detection of pharyngeal perforation

    International Nuclear Information System (INIS)

    Keberle, M.; Wittenberg, G.; Trusen, A.; Hahn, D.; Baumgartner, W.

    2001-01-01

    Purpose: In contrast to esophageal perforations, the more radiopaque barium-suspensions are not as important as iodinated aqueous contrast agents for the detection of pharyngeal perforations. This study was performed to find out whether the highly different viscosities (of iodinated and barium-containing contrast agents with comparable radiopacities) are a reason for this. Methods: Viscosity, subjective difference in contrast, and CT-density of an iodinated aqueous (Telebrix) and a 50 wt/vol% barium-containing contrast agent (Micropaque) were determined. Moreover, to exclude postoperative perforation, 104 patients were prospectively examined by pharyngography using both contrast media. Pharyngographies of patients with perforation were later compared by two independent readers. All patients with perforation were followed up clinically to exclude complications due to barium administration. Results: In-vitro comparison showed comparable radiopacity but the 50 wt/vol% barium-suspension was much more viscous that the iodinated contrast agent. During pharyngography, totally, 14 perforations were clearly delineated with the iodinated aqueous contrast agent. However, two of them were not detected with the barium-suspension. All the other perforations presented equally. Conclusions: Given a sufficient radiopacity, a low viscosity appears to be essential for a contrast agent to detect especially pharyngeal perforations. Thus, we recommend the sole use of an iodinated contrast agent (at suspicion of aspiration as isoosmolar variant) for this purpose. (orig.) [de

  15. Intravenous contrast media application using cone-beam computed tomography in a rabbit model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Sung; Kim, Bok Yeol; Choi, Hwa Young [Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University, Seoul (Korea, Republic of); and others

    2015-03-15

    This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.

  16. Intravenous contrast media application using cone-beam computed tomography in a rabbit model

    International Nuclear Information System (INIS)

    Kim, Min Sung; Kim, Bok Yeol; Choi, Hwa Young

    2015-01-01

    This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.

  17. Fundamental studies of oral contrast agents for MR. Comparison of manganese agent and iron agent

    International Nuclear Information System (INIS)

    Fujita, Osamu; Hiraishi, Kumiko; Suginobu, Yoshito; Takeuchi, Masayasu; Narabayashi, Isamu

    1996-01-01

    We investigated and compared signal intensity and the effect of imaging the upper abdomen with blueberry juice (B.J.), a Mn agent utilizing the properties of paramagnetic metals, and FerriSeltz (F.S.), an iron agent. Since the relaxation effect was much stronger with B.J. than with F.S., the signal intensity required of a peroral contrast agent was able to be obtained at a much lower concentration of B.J. In imaging the upper abdomen, B.J. had a positive effect on imaging in T1-weighted images, and a negative effect in T2-weighted images. F.S. had a positive imaging effect in both, and because it showed extremely high signals in T2-weighted images, motion artifact arose. (author)

  18. The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography

    International Nuclear Information System (INIS)

    Schueltke, E.; Fiedler, S.; Kelly, M.; Griebel, R.; Juurlink, B.; LeDuc, G.; Esteve, F.; Le Bas, J.-F.; Renier, M.; Nemoz, C.; Meguro, K.

    2005-01-01

    Background: Catheterization of small-caliber blood vessels in the central nervous system can be extremely challenging. Alternatively, intravenous (i.v.) administration of contrast agent is minimally invasive and therefore carries a much lower risk for the patient. With conventional X-ray equipment, volumes of contrast agent that could be safely administered to the patient do not allow acquisition of high-quality images after i.v. injection, because the contrast bolus is extremely diluted by passage through the heart. However, synchrotron-based digital K-edge subtraction angiography does allow acquisition of high-quality images after i.v. administration of relatively small doses of contrast agent. Materials and methods: Eight adult male New Zealand rabbits were used for our experiments. Animals were submitted to both angiography with conventional X-ray equipment and synchrotron-based digital subtraction angiography. Results: With conventional X-ray equipment, no contrast was seen in either cerebral or spinal blood vessels after i.v. injection of iodinated contrast agent. However, using K-edge digital subtraction angiography, as little as 1 ml iodinated contrast agent, when administered as i.v. bolus, yielded images of small-caliber blood vessels in the central nervous system (both brain and spinal cord). Conclusions: If it would be possible to image blood vessels of the same diameter in the central nervous system of human patients, the synchrotron-based technique could yield high-quality images at a significantly lower risk for the patient than conventional X-ray imaging. Images could be acquired where catheterization of feeding blood vessels has proven impossible

  19. A functionalized superparamagnetic iron oxide colloid as a receptor directed MR contrast agent

    International Nuclear Information System (INIS)

    Josephson, L.; Groman, E.V.; Menz, E.; Lewis, J.M.; Bengele, H.

    1990-01-01

    We have synthesized a surface functionalized superparamagnetic iron oxide colloid whose clearance from the vascular compartment was inhibited by asialofetuin but not fetuin. Unlike other particulate or colloidal magnetic resonance (MR) contrast agents, the agent of the current communication is not withdrawn from the vascular compartment by cells of the macrophage-monocyte phagocytic system, as indicated by its selective increase in hepatic relaxation rates. Because of this we refer to this colloid as a hepatic selective (HS) MR contrast agent. At 20 mumol Fe/kg the HS MR agent darkened MR images of liver. The HS MR agent exhibited no acute toxicity when injected into rats at 1800 mumol Fe/kg. Based on these observations, surface functionalized superparamagnetic iron oxide colloids may be the basis of MR contrast agents internalized by receptor mediated endocytosis generally, and by the asialoglycoprotein receptor in particular

  20. Extravasation of radiographic contrast material and compartment syndrome in the hand: a case report

    Directory of Open Access Journals (Sweden)

    Torrededia Laura

    2011-02-01

    Full Text Available Abstract Radiocontrast agents are a type of medical contrast material used to improve the visibility of internal bodily structures in X-ray based imaging techniques such as computed tomography (CT or radiography. Radiocontrast agents are typically iodine or barium compounds. Extravasation of contrast is a possible complication of imaging studies performed with contrasts. Most extravasations cause minimal swelling or erythema, however, skin necrosis, ulceration and compartment syndrome may occur with extravasation of large volumes of contrast. A case report is presented in which significant extravasation of contrast was caused while injecting the contrast intravenously into the back of the hand of a 50 year old patient during computed tomography. The patient was undergoing chemotherapy. The patient developed a compartment syndrome and a fasciotomy was required. Treatment options are outlined and emphasis is made on prevention of this iatrogenic complication. Some of the preventive measures to avoid these complications include use of non-ionic contrast (low osmolarity, careful choice of the site of intravenous administration, and close monitoring of the patient during injection of contrast to minimize or prevent extravasation injuries. Clear information to patients and prompt recognition of the complication can allow for other non-surgical treatment options than the one required in this case.

  1. Comparison of positive and negative enteral contrast agents for MR imaging of the abdomen

    International Nuclear Information System (INIS)

    Kaminsky, S.; Langer, M.

    1994-01-01

    Following oral administration of a buffered gadopentetate-dimeglumine solution (Magnevist enteral R , 1 mmol/l, 6-17 ml/kg) T 1 -, proton-density- and T 2 -weighted spin-echo images of abdominal and retroperitoneal lesions were acquired (0.5 T). Gadopentetate is a signal-enhancing, positive MR contrast agent, intraluminar air served as a model of a signal-free, negative agent. In 21 patients contrast/noise ratios of gadopentetate and air versus lesions and fat were compared quantitatively (t-test). In T 1 - and T 2 -weighted images contrast/noise ratios of gadopentetate versus lesions were significantly higher than those of air. In proton-density images there was no significant difference. In T 1 - and proton-density images contrast/noise ratios of air versus abdominal fat were significantly higher than those of gadopentetate, in T 2 -weighted images gadopentetate had a significantly higher contrast/noise ratio than air. Signal-enhancing positive contrast agents seem advantageous over signal-free negative enteral MR contrast agents. (orig.) [de

  2. An experimental study on tissue reaction of various contrast agents on endometrium, tuber mucosa, and peritoneum

    International Nuclear Information System (INIS)

    Kim, Jae Seung; Kim, Seung Hyup; Park, In Ae; Park, Jae Hyung; Yoon, Dae Young; Yeon, Kyung Mo

    1994-01-01

    To compare the tissue reactions of various water-soluble and oil-based contrast agents on the endometrium, salpingeal mumosa, and peritoneum. Thirty-three rabbits were used for evaluating the histologic reactions of uterine endometrium, salpinx, and peritoneum. Hysterosalpingography(HSG) was underwent in these rabbits by used Lipiodol, Hexabrix, Rayvist. Ultravist-300, Ultravist-370, and normal saline. Pathologic results were obtained in each of the six groups from the uterine endometrium, salpingeal mucosa, and peritoneum without knowledge of the contrast agent used and time interval from HSG. Mild inflammations were observed in the endometrium, salpingeal mucosa, and peritoneum during the first week of HSG in all rabbits in which water-soluble contrast agents were used. Although there was no significant difference in the degree of inflammation among the groups using various contrast agents, the group with oil-based contrast agent(Lipiodol) showed delayed absorption of contrast agent in the peritoneum, frequent intravasation, fat granuloma, peritoneal adhesion, or uterine infarction. Our results suggest that water-soluble contrast agents can be used safely for HSG, but the use of oil-based contrast agent is questional in safety and should be avoid in patients with tubal obstruction, salpingitis, or endometritis

  3. Novel contrast agent for liver and spleen

    International Nuclear Information System (INIS)

    Seltzer, S.E.; Blau, M.; Adams, D.F.; Janoff, A.; Minchey, S.

    1991-01-01

    This paper determines whether the biodistribution and imaging characteristics of a liposome-encapsulated contrast agent, iotrolan-carrying interdigitation fusion (IF) vesicles, were acceptable for a liver-spleen CT contrast agent. IF vesicles with iotrolan in their aqueous phase were prepared by fusing small unilamellar liposomes into larger vesicles. The iodine-to-lipid ratio was 4.7. Biodistribution was measured with I-125 iotrolan-labeled IF vesicles in rats. CT imaging (Somatom Plus, Siemens Medical Systems) was performed in dogs. At the lowest dose (10 mg of iodine and 2.1 mg of lipid per kilogram) 72% of the ID was in the liver, 5% in spleen, and 1% in lungs at 1 hour. At the highest dose, (1,000 mg of iodine and 212 mg of lipid per kilogram), liver values were 68% ID, while spleen rose to 18%, lung 5%. Liver and spleen values stayed at peak for 24 hours then fell; the half-life was 6 days. In dogs, liver and spleen enhancement at 1 hour averaged 652 and 256 HU above baseline per gram of iodine per kilogram, respectively

  4. Case with high cervical intramedullary hemangioblastoma associated with arteriovenous fistula. CT with simultaneous intravenous and intrathecal injection of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takao; Shoji, Shin-ichi; Yanagisawa, Nobuo; Tada, Tsuyoshi; Kobayashi, Naoki

    1988-02-01

    A 34-year-old woman complained of right hemiparesis and pain in the right hand. Routine X-ray of the cervical portion failed to reveal abnormal findings. CT with intravenous contrast medium showed a large high-density mass in the spinal canal at the level of C2. Right vertebral angiography showed a hypervascular mass. With simultaneous intravenous and intrathecal injections of contrast medium, the tumor was shown as a moderately high-density area and the parenchyma of cord as a thin low-density area surrounding the tumor stain on CT. These CT appearances led to the final diagnosis of high cervical intramedullary hemangioblastoma associated with arteriovenous fistulae. Pathological findings are typical of hemangioblastoma. The usefulness of CT in detecting the localization of hypervascular spinal cord lesions is stressed. (Namekawa, K.).

  5. Investigation of X-ray permeability of surgical gloves coated with different contrast agents

    Science.gov (United States)

    Kayan, Mustafa; Yaşar, Selçuk; Saygın, Mustafa; Yılmaz, Ömer; Aktaş, Aykut Recep; Kayan, Fatmanur; Türker, Yasin; Çetinkaya, Gürsel

    2016-01-01

    Objective: We aimed to investigate the effectiveness and radiation protection capability of latex gloves coated with various contrast agents as an alternative to lead gloves. Methods: The following six groups were created to evaluate the permeability of X-ray in this experimental study: lead gloves, two different non-ionic contrast media (iopromide 370/100 mg I/mL and iomeprol 400/100 mg I/mL), 10% povidone–iodine (PV–I), 240/240 g/mL barium sulphate and a mixture of equal amounts of all contrast agents. A radiation dose detector was placed in coated latex gloves for each one. The absorption values of radiation from latex gloves coated with various contrast agents were measured and compared with the absorption of radiation from lead gloves. This study was designed as an ‘experimental study’. Results: The mean absorption value of X-ray from lead gloves was 3.0±0.08 µG/s. The mean absorption values of X-ray from latex gloves coated with various contrast agents were 3.7±0.09 µG/s (iopromide 370/100 mg I/mL), 3.6±0.09 µG/s (iomeprol 400/100 mg I/mL), 3.7±0.04 µG/s (PV–I), 3.1±0.07 µG/s (barium sulphate) and 3.8±0.05 µG/s (mixture of all contrast agents). Latex gloves coated with barium sulphate provided the best radiation absorption compared with latex gloves coated with other radiodense contrast agents. Conclusion: Latex gloves coated with barium sulphate may provide protection equivalent to lead gloves. PMID:26680548

  6. Photoacoustic/ultrasound dual-modality contrast agent and its application to thermotherapy.

    Science.gov (United States)

    Wang, Yu-Hsin; Liao, Ai-Ho; Chen, Jui-Hao; Wang, Churng-Ren Chris; Li, Pai-Chi

    2012-04-01

    This study investigates a photoacoustic/ultrasound dual-modality contrast agent, including extending its applications from image-contrast enhancement to combined diagnosis and therapy with site-specific targeting. The contrast agent comprises albumin-shelled microbubbles with encapsulated gold nanorods (AuMBs). The gas-filled microbubbles, whose diameters range from submicrometer to several micrometers, are not only echogenic but also can serve as drug-delivery vehicles. The gold nanorods are used to enhance the generation of both photoacoustic and photothermal signals. The optical absorption peak of the gold nanorods is tuned to 760 nm and is invariant after microbubble encapsulation. Dual-modality contrast enhancement is first described here, and the applications to cellular targeting and laser-induced thermotherapy in a phantom are demonstrated. Photoacoustic imaging can be used to monitor temperature increases during the treatment. The targeting capability of AuMBs was verified, and the temperature increased by 26°C for a laser power of 980 mW, demonstrating the potential of combined diagnosis and therapy with the dual-modality agent. Targeted photo- or acoustic-mediated delivery is also possible.

  7. Non-toxic lead sulfide nanodots as efficient contrast agents for visualizing gastrointestinal tract.

    Science.gov (United States)

    Liu, Zhen; Ran, Xiang; Liu, Jianhua; Du, Yingda; Ren, Jinsong; Qu, Xiaogang

    2016-09-01

    Non-invasive imaging of gastrointestinal (GI) tract using novel but efficient contrast agents is of the most important issues in the diagnosis and prognosis of GI diseases. Here, for the first time, we reported the design and synthesis of biothiol-decorated lead sulfide nanodots, as well as their usages in functional dual-modality imaging of GI tract in vivo. Due to the presence of glutathione on the surface of the nanodots, these well-prepared contrast agents could decrease the unwanted ion leakage, withstand the harsh conditions in GI tract, and avoid the systemic absorption after oral administration. Compared with clinical barium meal and iodine-based contrast agents, these nanodots exhibited much more significant enhancement in contrast efficiency during both 2D X-ray imaging and 3D CT imaging. Different from some conventional invasive imaging modalities, such as gastroscope and enteroscope, non-invasive imaging strategy by using glutathione modified PbS nanodots as contrast agents could reduce the painfulness towards patients, facilitate the imaging procedure, and economize the manipulation period. Moreover, long-term toxicity and bio-distribution of these nanodots after oral administration were evaluated in detail, which indicated their overall safety. Based on our present study, these nanodots could act as admirable contrast agents to integrate X-ray imaging and CT imaging for the direct visualization of GI tract. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Kinetics of intravenous radiographic contrast medium injections as used on CT: simulation with time delay differential equations in a basic human cardiovascular multicompartment model.

    Science.gov (United States)

    Violon, D

    2012-12-01

    To develop a multicompartment model of only essential human body components that predicts the contrast medium concentration vs time curve in a chosen compartment after an intravenous injection. Also to show that the model can be used to time adequately contrast-enhanced CT series. A system of linked time delay instead of ordinary differential equations described the model and was solved with a Matlab program (Matlab v. 6.5; The Mathworks, Inc., Natick, MA). All the injection and physiological parameters were modified to cope with normal or pathological situations. In vivo time-concentration curves from the literature were recalculated to validate the model. The recalculated contrast medium time-concentration curves and parameters are given. The results of the statistical analysis of the study findings are expressed as the median prediction error and the median absolute prediction error values for both the time delay and ordinary differential equation systems; these are situated well below the generally accepted maximum 20% limit. The presented program correctly predicts the time-concentration curve of an intravenous contrast medium injection and, consequently, allows an individually tailored approach of CT examinations with optimised use of the injected contrast medium volume, as long as time delay instead of ordinary differential equations are used. The presented program offers good preliminary knowledge of the time-contrast medium concentration curve after any intravenous injection, allowing adequate timing of a CT examination, required by the short scan time of present-day scanners. The injected volume of contrast medium can be tailored to the individual patient with no more contrast medium than is strictly needed.

  9. Smart Contrast Agents for Magnetic Resonance Imaging.

    Science.gov (United States)

    Bonnet, Célia S; Tóth, Éva

    2016-01-01

    By visualizing bioactive molecules or biological parameters in vivo, molecular imaging is searching for information at the molecular level in living organisms. In addition to contributing to earlier and more personalized diagnosis in medicine, it also helps understand and rationalize the molecular factors underlying physiological and pathological processes. In magnetic resonance imaging (MRI), complexes of paramagnetic metal ions, mostly lanthanides, are commonly used to enhance the intrinsic image contrast. They rely either on the relaxation effect of these metal chelates (T(1) agents), or on the phenomenon of paramagnetic chemical exchange saturation transfer (PARACEST agents). In both cases, responsive molecular magnetic resonance imaging probes can be designed to report on various biomarkers of biological interest. In this context, we review recent work in the literature and from our group on responsive T(1) and PARACEST MRI agents for the detection of biogenic metal ions (such as calcium or zinc), enzymatic activities, or neurotransmitter release. These examples illustrate the general strategies that can be applied to create molecular imaging agents with an MRI detectable response to biologically relevant parameters.

  10. Synthesis and characterization of a smart contrast agent sensitive to calcium.

    Science.gov (United States)

    Dhingra, Kirti; Maier, Martin E; Beyerlein, Michael; Angelovski, Goran; Logothetis, Nikos K

    2008-08-07

    A novel first-generation Ca2+ sensitive contrast agent, Gd-DOPTRA has been synthesized and characterized. The agent shows approximately 100% relaxivity enhancement upon addition of Ca2+. The agent is selective and sensitive to Ca2+ also in the presence of Mg2+ and Zn2+. The relaxivity studies carried out in physiological fluids prove the prospects of the agent for in vivo measurements.

  11. The primary applications of Gd-DTPA as an oral negative gastrointestinal contrast agent for MRCP

    International Nuclear Information System (INIS)

    Chen Yanping; Zhang Xuelin; Cheng Guanxun; Chang Renmin; Zhang Yuzhong; Cang Peng; Xia Qiong

    2003-01-01

    Objective: Using oral Gd-DTPA as a negative contrast agent to null the bowel signal during MR cholangiopancreatography (MRCP) to improve the quality of MRCP. Methods: A phantom study was performed to select the optimal concentration of Gd-DTPA to be used as an oral negative contrast agent in MRCP. 15 patients suspected of biliary tract and pancreatic disease were performed with MRCP before and after using 250 ml oral contrast agents (1:5 diluted Gd-DTPA, 1.488 g/L). All MR images were acquired using a 1.5 T whole body MR scanner (Vision Plus, Siemens). MRCP was acquired using two-dimensional single slice fast spin-echo sequence and HASTE (half-fourier acquisition single-shot fast spin echo) sequence. Results: The phantom study showed that the dilution ratio 1:5 of Gd-DTPA oral contrast agent was best in decreasing the signal intensity both in T 2 WI (59.3%) and in HASTE sequence (82.45%). All the dilution ratio of Gd-DTPA oral contrast agent decreased the signal intensity up to 90% on single slice MRCP. In all the patients the high signal intensity from the stomach and intestinal fluid was completely suppressed. The depictions of common bile duct and pancreatic duct were markedly improved by the oral contrast agent (P<0.05). Conclusion: 1:5 diluted (1.488 g/L) oral MR contrast agent Gd-DTPA can be an effective and safe negative contrast agent in eliminating signal intensity of the gastrointestinal tract, thus improving the depiction of the biliary system in MRCP

  12. Research on a new oral contrast agent for abdominal MRI using free manganese ion

    International Nuclear Information System (INIS)

    Hasegawa, Hideo; Fujita, Osamu; Hiraishi, Kumiko; Narabayashi, Isamu; Komba, Toshinori; Hamamura, Yoshinori.

    1996-01-01

    Manganese chloride (Mn: 3 mg/100 g) aqueous solution with hydragenated oligosaccharide and xanthan gum (T 1 : 0.1 sec, T 2 : 0.03 sec at 0.5T) functions in gut as a positive contrast agent on MR T 1 -weighted images and a low signal component on MR T 2 -weighted images. The manganese in the solution functions as a contrast agent under free manganese ion (Mn 2+ ). Further, the solution has special characteristics in terms of MRI signal intensity and relaxation time that are equal to those of blueberry juice, which performs as an effective contrast agent on T 1 -and T 2 -weighted images, and functions as a contrast agent in vitro and in vivo. (author)

  13. Quantitative Differences Between the First and Second Injection of Contrast Agent in Contrast-Enhanced Ultrasonography of Feline Kidneys and Spleen.

    Science.gov (United States)

    Stock, Emmelie; Vanderperren, Katrien; Haers, Hendrik; Duchateau, Luc; Hesta, Myriam; Saunders, Jimmy H

    2017-02-01

    Contrast-enhanced ultrasound is a valuable and safe technique for the evaluation of organ perfusion. Repeated injections of ultrasound contrast agent are often administered during the same imaging session. However, it remains unclear if quantitative differences are present between the consecutive microbubble injections. Therefore, the first and second injection of contrast agent for the left renal cortex, renal medulla and the splenic parenchyma in healthy cats were compared. A lower peak intensity and area under the curve were observed for the first injection of contrast agent in the feline kidney, both for the renal cortex and medulla, and spleen. Moreover, for the renal cortex, the time-intensity curve was steeper after the second injection. Findings from the present study demonstrate that a second injection of contrast agent provides stronger enhancement. The exact mechanism behind our findings remains unclear; however, saturation of the lung macrophages is believed to play an important role. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  14. Prevention of radiographic-contrast-agent-induced reductions in renal function by acetylcysteine

    DEFF Research Database (Denmark)

    Tepel, Martin; van der Giet, M; Schwarzfeld, C

    2000-01-01

    Radiographic contrast agents can cause a reduction in renal function that may be due to reactive oxygen species. Whether the reduction can be prevented by the administration of antioxidants is unknown.......Radiographic contrast agents can cause a reduction in renal function that may be due to reactive oxygen species. Whether the reduction can be prevented by the administration of antioxidants is unknown....

  15. Acoustic bubble sorting for ultrasound contrast agent enrichment

    NARCIS (Netherlands)

    Segers, T.J.; Versluis, Michel

    2014-01-01

    An ultrasound contrast agent (UCA) suspension contains encapsulated microbubbles with a wide size distribution, with radii ranging from 1 to 10 μm. Medical transducers typically operate at a single frequency, therefore only a small selection of bubbles will resonate to the driving ultrasound pulse.

  16. Ultrasonographic detection of focal liver lesions: increased sensitivity and specificity with microbubble contrast agents

    International Nuclear Information System (INIS)

    Hohmann, J.; Albrecht, T.; Hoffmann, C.W.; Wolf, K.-J.

    2003-01-01

    Ultrasonography (US) is the first choice for screening patients with suspected liver lesions. However, due to a lack of contrast agents, US used to be less sensitive and specific compared with computed tomography (CT) and magnet resonance imaging (MRI). The advent of microbubble contrast agents increased both sensitivity and specificity dramatically. Rapid developments of the contrast agents as well as of special imaging techniques were made in recent years. Today numerous different US imaging methods exist which based either on Doppler or on harmonic imaging. They are using the particular behaviour of microbubbles in a sound field which varies depending on the energy of insonation (low/high mechanical index, MI) as well as on the properties of the agent themselves. Apart from just blood pool enhancement some agents have a hepatosplenic specific late phase. US imaging during this late phase using relatively high MI in phase inversion mode (harmonic imaging) or stimulated acoustic emission (SAE; Doppler method) markedly improves the detection of focal liver lesions and is also very helpful for lesion characterisation. With regards to detection, contrast enhanced US performs similarly to CT as shown by recent studies. Early results of studies using low MI imaging and the newer perfluor agents are also showing promising results for lesion detection. Low MI imaging with these agents has the advantage of real time imaging and is particularly helpful for characterisation of focal lesions based on their dynamic contrast behaviour. Apart from the techniques which based on the morphology of liver lesions there were some attempts for the detection of occult metastases or micrometastases by means of liver blood flow changes. Also in this field the use of US contrast agents appears to have advantages over formerly used non contrast-enhanced methods although no conclusive results are available yet

  17. Impact of Impaired Renal Function on Gadolinium Retention After Administration of Gadolinium-Based Contrast Agents in a Mouse Model.

    Science.gov (United States)

    Kartamihardja, A Adhipatria P; Nakajima, Takahito; Kameo, Satomi; Koyama, Hiroshi; Tsushima, Yoshito

    2016-10-01

    The aim of this study was to investigate the impact of impaired renal function on gadolinium (Gd) retention in various organs after Gd-based contrast agent injection. After local animal care and review committee approval, 23 normal mice and 26 with renal failure were divided into 4 treatment groups (Gd-DTPA-BMA, 5 mmol/kg; Gd-DOTA, 5 mmol/kg; GdCl3, 0.02 mmol/kg; and saline, 250 μL). Each agent was intravenously administered on weekdays for 4 weeks. Samples were collected on days 3 (short-term) and 45 (long-term) after the last injection. Gadolinium concentrations were quantified by inductively coupled plasma-mass spectrometry. Three mice with renal failure and 2 normal mice in the GdCl3 group and 1 mouse with renal failure in the Gd-DTPA-BMA group died. In the Gd-DTPA-BMA group, impaired renal function increased short-term Gd retention in the liver, bone, spleen, skin, and kidney (P DTPA-BMA showed higher Gd retention than Gd-DOTA. Although Gd retention in the Gd-DOTA group was generally low, impaired renal function increased only long-term hepatic Gd retention. Hepatic and splenic Gd retentions were significantly higher than other organs' Gd retention in the GdCl3 group (P DTPA-BMA administration, long-term Gd retention for Gd-based contrast agents was almost unaffected by renal function, suggesting that the chemical structures of retained Gd may not be consistent and some Gd is slowly eliminated after initially being retained.

  18. Magnetic resonance angiography with blood-pool contrast agents: future applications

    International Nuclear Information System (INIS)

    Fink, C.; Goyen, M.; Lotz, J.

    2007-01-01

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  19. Magnetic resonance angiography with blood-pool contrast agents: future applications

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C. [Univ. Hospitals, Grosshadern, Munich (Germany); Goyen, M. [Univ. Medical Center, Hamburg-Eppendorf, Hamburg (Germany); Lotz, J. [Hannover Medical School, Hannover (Germany)

    2007-03-15

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  20. Gd-DTPA as a paramagnetic contrast agent in MR imaging of focal liver lesions

    International Nuclear Information System (INIS)

    Hamm, B.; Roemer, T.; Wolf, K.J.; Felix, R.; Weinmann, H.J.

    1986-01-01

    Gd-DTPA enhances signal intensity in healthy liver and in intrahepatic tumors. However, after contrast agent administration, tumor enhances significantly more than liver parenchyma (2α≤ 0.05). Doubling the dose of Gd-DTPA from 0.1 to 0.2 mmol/kg of body weight increases the enhancement of intrahepatic tumors (2α≤ 0.05) and optimizes the contrast between tumor and liver in T1-weighted spin-echo sequences. However, the contrast between tumor and liver on inversion-recovery and T2-weighted images obtained before contrast agent administration is much greater than the difference on T1-weighted images obtained after contrast agent administration (2α≤ 0.05). In fast images the contrast between liver and tumor can be markedly improved by administering Gd-DTPA

  1. Contrast enhancement by differently sized paramagnetic MRI contrast agents in mice with two phenotypes of atherosclerotic plaque

    NARCIS (Netherlands)

    van Bochove, Glenda S.; Paulis, Leonie E. M.; Segers, Dolf; Mulder, Willem J. M.; Krams, Rob; Nicolay, Klaas; Strijkers, Gustav J.

    2011-01-01

    Interest in the use of contrast-enhanced MRI to enable in vivo specific characterization of atherosclerotic plaques is increasing. In this study the intrinsic ability of three differently sized gadolinium-based contrast agents to permeate different mouse plaque phenotypes was evaluated with MRI. A

  2. Towards MRI T2 contrast agents of increased efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Branca, Marlène [CNRS, LCC (Laboratoire de Chimie de Coordination), 205, route de Narbonne, F-31077 Toulouse (France); Université de Toulouse, UPS, INPT, LCC, F-31077 Toulouse (France); Marciello, Marzia, E-mail: marziamarciello@icmm.csic.es [Instituto de Ciencia de Materiales de Madrid (ICMM-CSIC), Sor Juana Inés de la Cruz, 3, Cantoblanco, 28049 Madrid (Spain); Ciuculescu-Pradines, Diana [CNRS, LCC (Laboratoire de Chimie de Coordination), 205, route de Narbonne, F-31077 Toulouse (France); Université de Toulouse, UPS, INPT, LCC, F-31077 Toulouse (France); Respaud, Marc [LPCNO, INSA, 135 Avenue de Rangueil, 31077 Toulouse Cedex 4 (France); Morales, Maria del Puerto [Instituto de Ciencia de Materiales de Madrid (ICMM-CSIC), Sor Juana Inés de la Cruz, 3, Cantoblanco, 28049 Madrid (Spain); Serra, Raphael; Casanove, Marie-José [CNRS, CEMES (Centre d' Elaboration des Matériaux et d' Etudes Structurales) (France); Amiens, Catherine, E-mail: catherine.amiens@lcc-toulouse.fr [CNRS, LCC (Laboratoire de Chimie de Coordination), 205, route de Narbonne, F-31077 Toulouse (France); Université de Toulouse, UPS, INPT, LCC, F-31077 Toulouse (France)

    2015-03-01

    Magnetic nanoparticles can be efficient contrast agents for T2 weighted magnetic resonance imaging (MRI) after tuning of some key parameters such as size, surface state, colloidal stability and magnetization, thus motivating the development of new synthetic pathways. In this paper we report the effects of surface coating on the efficiency of two different types of iron based nanoparticles (NPs) as MRI contrast agents. Starting from well-defined hydrophobic iron oxide nanospheres and iron nanocubes of 13 nm size, we have used three methods to increase their hydrophilicity and transfer them into water: surface ligand modification, ligand exchange or encapsulation. The NPs obtained have been characterized by dynamic light scattering and transmission electron microscopy, and the relaxivities of their stable colloidal solutions in water have been determined. Among all samples prepared, iron nanocubes coated by silica display the highest relaxivity (r{sub 2}) value: 628 s{sup −1} mM{sup −1}. - Highlights: • Surface coating effect on the efficiency of iron based nanoparticles (NPs) as MRI contrast agents. • Synthesis of 2 different types of hydrophobic iron based NPs: iron oxide nanospheres and iron nanocubes (13 nm). • Development of three different procedures to stabilize iron based NPs in water. • Iron nanocubes coated by silica displayed the highest r{sub 2} value (628 s{sup −1} mM{sup −1})

  3. Optimal Contrast Agent Staining of Ligaments and Tendons for X-Ray Computed Tomography.

    Science.gov (United States)

    Balint, Richard; Lowe, Tristan; Shearer, Tom

    2016-01-01

    X-ray computed tomography has become an important tool for studying the microstructures of biological soft tissues, such as ligaments and tendons. Due to the low X-ray attenuation of such tissues, chemical contrast agents are often necessary to enhance contrast during scanning. In this article, the effects of using three different contrast agents--iodine potassium iodide solution, phosphotungstic acid and phosphomolybdic acid--are evaluated and compared. Porcine anterior cruciate ligaments, patellar tendons, medial collateral ligaments and lateral collateral ligaments were used as the basis of the study. Three samples of each of the four ligament/tendon types were each assigned a different contrast agent (giving a total of twelve samples), and the progression of that agent through the tissue was monitored by performing a scan every day for a total period of five days (giving a total of sixty scans). Since the samples were unstained on day one, they had been stained for a total of four days by the time of the final scans. The relative contrast enhancement and tissue deformation were measured. It was observed that the iodine potassium iodide solution penetrated the samples fastest and caused the least sample shrinkage on average (although significant deformation was observed by the time of the final scans), whereas the phosphomolybdic acid caused the greatest sample shrinkage. Equations describing the observed behaviour of the contrast agents, which can be used to predict optimal staining times for ligament and tendon X-ray computed tomography, are presented.

  4. Novel route synthesis of porous and solid gold nanoparticles for investigating their comparative performance as contrast agent in computed tomography scan and effect on liver and kidney function.

    Science.gov (United States)

    Aziz, Farooq; Ihsan, Ayesha; Nazir, Aalia; Ahmad, Ishaq; Bajwa, Sadia Zafar; Rehman, Asma; Diallo, Abdoulaye; Khan, Waheed S

    2017-01-01

    Gold nanoparticles (GNPs) with dimension in the range of 1-100 nm have a prominent role in a number of biomedical applications like imaging, drug delivery, and cancer therapy owing to their unique optical features and biocompatibility. In this work, we report a novel technique for the synthesis of two types of GNPs namely porous gold nanoparticles (PGNPs) and solid gold nanoparticles (SGNPs). PGNPs of size 35 nm were fabricated by reduction of gold (III) solution with lecithin followed by addition of L-ascorbic acid and tri-sodium citrate, whereas SGNPs with a dimension of 28 nm were prepared by reflux method using lecithin as a single reducing agent. Comparative studies using PGNPs (λ max 560 nm) and SGNPs (λ max 548 nm) were conducted for evaluating their use as a contrast agent. These studies reveled that in direct computed tomography scan, PGNPs exhibited brighter contrast (45 HU) than SGNPs (26 HU). To investigate the effect of PGNPs and SGNPs on the liver and kidney profile, male rabbits were intravenously injected with an equal dose of 1 mg/kg weight of PGNPs and SGNPs. The effect on biochemical parameters was evaluated 72 hours after intravenous (IV) injection including liver function profile, renal (kidney) function biomarker, random blood glucose value, and cholesterol level. During one comparison of contrast in CT scan, PGNPs showed significantly enhanced contrast in whole-rabbit and organ CT scan as compared to SGNPs 6 hours after injection. Our findings suggested that the novel PGNPs enhance CT scan image with higher efficacy as compared to SGNPs. The results showed that IV administration of synthesized PGNPs increases the levels of aspartate aminotransferase (AST), alkaline phosphate (ALP), serum creatinine, and blood glucose, whereas that of SGNPs increases the levels of AST, ALP, and blood glucose.

  5. A targeted nanoglobular contrast agent from host-guest self-assembly for MR cancer molecular imaging.

    Science.gov (United States)

    Zhou, Zhuxian; Han, Zhen; Lu, Zheng-Rong

    2016-04-01

    The clinical application of nanoparticular Gd(III) based contrast agents for tumor molecular MRI has been hindered by safety concerns associated with prolonged tissue retention, although they can produce strong tumor enhancement. In this study, a targeted well-defined cyclodextrin-based nanoglobular contrast agent was developed through self-assembly driven by host-guest interactions for safe and effective cancer molecular MRI. Multiple β-cyclodextrins attached POSS (polyhedral oligomeric silsesquioxane) nanoglobule was used as host molecule. Adamantane-modified macrocyclic Gd(III) contrast agent, cRGD (cyclic RGDfK peptide) targeting ligand and fluorescent probe was used as guest molecules. The targeted host-guest nanoglobular contrast agent cRGD-POSS-βCD-(DOTA-Gd) specifically bond to αvβ3 integrin in malignant 4T1 breast tumor and provided greater contrast enhancement than the corresponding non-targeted agent. The agent also provided significant fluorescence signal in tumor tissue. The histological analysis of the tumor tissue confirmed its specific and effective targeting to αvβ3 integrin. The targeted imaging agent has a potential for specific cancer molecular MR and fluorescent imaging. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Quinone-fused porphyrins as contrast agents for photoacoustic imaging

    KAUST Repository

    Banala, Srinivas; Fokong, Stanley; Brand, Christian; Andreou, Chrysafis; Krä utler, Bernhard; Rueping, Magnus; Kiessling, Fabian

    2017-01-01

    Photoacoustic (PA) imaging is an emerging non-invasive diagnostic modality with many potential clinical applications in oncology, rheumatology and the cardiovascular field. For this purpose, there is a high demand for exogenous contrast agents

  7. Immediate hypersensitivity to iodinated contrast media: diagnostic accuracy of skin tests and intravenous provocation test with low dose.

    Science.gov (United States)

    Sesé, L; Gaouar, H; Autegarden, J-E; Alari, A; Amsler, E; Vial-Dupuy, A; Pecquet, C; Francès, C; Soria, A

    2016-03-01

    The diagnosis of HSR to iodinated contrast media (ICM) is challenging based on clinical history and skin tests. This study evaluates the negative predictive value (NPV) of skin tests and intravenous provocation test (IPT) with low-dose ICM in patients with suspected immediate hypersensitivity reaction (HSR) to ICM. Thirty-seven patients with suspected immediate hypersensitivity reaction to ICM were included retrospectively. Skin tests and a single-blind placebo-controlled intravenous provocation test (IPT) with low-dose iodinated contrast media (ICM) were performed. Skin tests with ICM were positive in five cases (one skin prick test and five intradermal test). Thirty-six patients were challenged successfully by IPT, and only one patient had a positive challenge result, with a grade I reaction by the Ring and Messmer classification. Ten of 23 patients followed up by telephone were re-exposed to a negative tested ICM during radiologic examination; two experienced a grade I immediate reaction. For immediate hypersensitivity reaction to ICM, the NPV for skin tests and IPT with low dose was 80% (95% CI 44-97%). © 2016 John Wiley & Sons Ltd.

  8. The feasibility of a targeted ultrasound contrast agent carrying genes and cell-penetrating peptides to hypoxic HUVEC

    International Nuclear Information System (INIS)

    Tian Ju; Wang Zhigang; Ren Jianli; Zhang Qingfeng; Liu Li

    2012-01-01

    Objective: To prepare an anti-P-selectin targeted ultrasound contrast agent carrying genes and cell-penetrating peptides (CPP) and to investigate its feasibility of delivery to hypoxic human umbilical vein endothelial cells (HUVEC). Methods: Anti-P-selectin targeted ultrasound contrast agent carrying a green fluorescent protein gene (pEGFP-N1) and CPP was prepared by mechanical vibration and carbodiimide techniques. The appearance, distribution, concentration and diameter of the ultrasound contrast agent were measured. The gene and CPP distribution on the agent was investigated using confocal laser scanning microscopy (CLSM). The efficiency of the ultrasound contrast agent to carry the gene and CPP was investigated by fluorospectrophotometry. HUVEC were cultured in vitro and hypoxic HUVEC were prepared using hydrogen peroxide (H 2 O 2 ). Hypoxic HUVEC were randomly assigned targeted ultrasound contrast agents and non-targeted ultrasound contrast agents for transfection. The transfection effect of green fluorescent protein in the two groups was observed using fluorescence microscopy and flow cytometry. T-test and linear correlation analysis were used for statistical analysis. Results: The average diameter of anti-P-selectin targeted ultrasound contrast agents carrying gene and CPP was (2.15 ±0.36) μm and the concentration was (1.58 ± 0.23) × 10 7 /ml.The results of CLSM showed that gene and CPP were distributed on the shell of the agent. The gene encapsulation efficiency was 28% (y=0.932x-0.09, r=0.993, P<0.05), and the CPP encapsulation efficiency was 25% (y=5.875x-0.81, r=0.987, P<0.05). EGFP expression was observed using fluorescence microscopy in targeted ultrasound contrast agents and non-targeted ultrasound contrast agents. The average transfection efficiencies of targeted ultrasound contrast agents and non-targeted ultrasound contrast agents were (18.74 ± 0.47) % and (15.34 ± 0.22) % after 24 h (t=10.923, P<0.001). Conclusions: The in vitro studies

  9. Measuring SPIO and Gd contrast agent magnetization using 3 T MRI

    Science.gov (United States)

    Cantillon-Murphy, Pádraig; Wald, Lawrence L.; Zahn, Markus; Adalsteinsson, Elfar

    2011-01-01

    Traditional methods of measuring magnetization in magnetic fluid samples, such as vibrating sample magnetometry (VSM), are typically limited to maximum field strengths of about 1 T. This work demonstrates the ability of MRI to measure the magnetization associated with two commercial MRI contrast agents at 3 T by comparing analytical solutions to experimental imaging results for the field pattern associated with agents in cylindrical vials. The results of the VSM and fitted MRI data match closely. The method represents an improvement over VSM measurements since results are attainable at imaging field strengths. The agents investigated are Feridex, a superparamagnetic iron oxide suspension used primarily for liver imaging, and Magnevist, a paramagnetic, gadolinium-based compound used for tumors, inflammation and vascular lesions. MR imaging of the agents took place in sealed cylindrical vials in the presence of a surrounding volume of deionized water where the effects of the contrast agents had a measurable effect on the water's magnetization in the vicinity of the compartment of contrast agent. A pair of phase images were used to reconstruct a B0 fieldmap. The resultant B0 maps in the water region, corrected for shimming and container edge effects, were used to predict the agent's magnetization at 3 T. The results were compared with the results from VSM measurements up to 1.2 T and close correlation was observed. The technique should be of interest to those seeking quantification of the magnetization associated with magnetic suspensions beyond the traditional scope of VSM. The magnetization needs to be sufficiently strong (Ms≳50 Am2/kg Fe for Feridex and χm≳5 × 10−5 m3/kg Gd for Magnevist) for a measurable dipole field in the surrounding water. For this reason, the technique is mostly suitable for undiluted agents. PMID:19588450

  10. Tumor Vessel Compression Hinders Perfusion of Ultrasonographic Contrast Agents

    Directory of Open Access Journals (Sweden)

    Mirco Galiè

    2005-05-01

    Full Text Available Contrast-enhanced ultrasound (CEUS is an advanced approach to in vivo assessment of tumor vascularity and is being increasingly adopted in clinical oncology. It is based on 1- to 10 μm-sized gas microbubbles, which can cross the capillary beds of the lungs and are effective echo enhancers. It is known that high cell density, high transendothelial fluid exchange, and poorly functioning lymphatic circulation all provoke solid stress, which compresses vessels and drastically reduces tumor blood flow. Given their size, we supposed that the perfusion of microbubbles is affected by anatomic features of tumor vessels more than are contrast agents traditionally used in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI. Here, we compared dynamic information obtained from CEUS and DCE-MRI on two experimental tumor models exhibiting notable differences in vessel anatomy. We found that tumors with small, flattened vessels show a much higher resistance to microbubble perfusion than to MRI contrast agents, and appear scarcely vascularized at CEUS examination, despite vessel volume adequate for normal function. Thus, whereas CEUS alone could induce incorrect diagnosis when tumors have small or collapsed vessels, integrated analysis using CEUS and DCE-MRI allows in vivo identification of tumors with a vascular profile frequently associated with malignant phenotypes.

  11. Advanced Contrast Agents for Multimodal Biomedical Imaging Based on Nanotechnology.

    Science.gov (United States)

    Calle, Daniel; Ballesteros, Paloma; Cerdán, Sebastián

    2018-01-01

    Clinical imaging modalities have reached a prominent role in medical diagnosis and patient management in the last decades. Different image methodologies as Positron Emission Tomography, Single Photon Emission Tomography, X-Rays, or Magnetic Resonance Imaging are in continuous evolution to satisfy the increasing demands of current medical diagnosis. Progress in these methodologies has been favored by the parallel development of increasingly more powerful contrast agents. These are molecules that enhance the intrinsic contrast of the images in the tissues where they accumulate, revealing noninvasively the presence of characteristic molecular targets or differential physiopathological microenvironments. The contrast agent field is currently moving to improve the performance of these molecules by incorporating the advantages that modern nanotechnology offers. These include, mainly, the possibilities to combine imaging and therapeutic capabilities over the same theranostic platform or improve the targeting efficiency in vivo by molecular engineering of the nanostructures. In this review, we provide an introduction to multimodal imaging methods in biomedicine, the sub-nanometric imaging agents previously used and the development of advanced multimodal and theranostic imaging agents based in nanotechnology. We conclude providing some illustrative examples from our own laboratories, including recent progress in theranostic formulations of magnetoliposomes containing ω-3 poly-unsaturated fatty acids to treat inflammatory diseases, or the use of stealth liposomes engineered with a pH-sensitive nanovalve to release their cargo specifically in the acidic extracellular pH microenvironment of tumors.

  12. Assessment of MRI Contrast Agent Kinetics via Retro-Orbital Injection in Mice: Comparison with Tail Vein Injection.

    Science.gov (United States)

    Wang, Fang; Nojima, Masanori; Inoue, Yusuke; Ohtomo, Kuni; Kiryu, Shigeru

    2015-01-01

    It is not known whether administration of contrast agent via retro-orbital injection or the tail vein route affects the efficiency of dynamic contrast-enhanced magnetic resonance imaging (MRI). Therefore, we compared the effects of retro-orbital and tail vein injection on the kinetics of the contrast agent used for MRI in mice. The same group of nine healthy female mice received contrast agent via either route. An extracellular contrast agent was infused via the tail vein and retro-orbital vein, in random order. Dynamic contrast-enhanced MRI was performed before and after administering the contrast agent. The contrast effects in the liver, kidney, lung, and myocardium were assessed. The average total times of venous puncture and mounting of the injection system were about 10 and 4 min for the tail vein and retro-orbital route, respectively. For all organs assessed, the maximum contrast ratio occurred 30 s after administration and the time course of the contrast ratio was similar with either routes. For each organ, the contrast ratios correlated strongly; the contrast ratios were similar. The retro-orbital and tail vein routes afforded similar results in terms of the kinetics of the contrast agent. The retro-orbital route can be used as a simple efficient alternative to tail vein injection for dynamic contrast-enhanced MRI of mice.

  13. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Joyce T. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Robinson, Joshua D. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Deng, Jie [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Rigsby, Cynthia K. [Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States)

    2016-12-15

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  14. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Johnson, Joyce T.; Robinson, Joshua D.; Deng, Jie; Rigsby, Cynthia K.

    2016-01-01

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  15. Noninvasive visualization of in vivo release and intratumoral distribution of surrogate MR contrast agent using the dual MR contrast technique.

    Science.gov (United States)

    Onuki, Yoshinori; Jacobs, Igor; Artemov, Dmitri; Kato, Yoshinori

    2010-09-01

    A direct evaluation of the in vivo release profile of drugs from carriers is a clinical demand in drug delivery systems, because drug release characterized in vitro correlates poorly with in vivo release. The purpose of this study is to demonstrate the in vivo applicability of the dual MR contrast technique as a useful tool for noninvasive monitoring of the stability and the release profile of drug carriers, by visualizing in vivo release of the encapsulated surrogate MR contrast agent from carriers and its subsequent intratumoral distribution profile. The important aspect of this technique is that it incorporates both positive and negative contrast agents within a single carrier. GdDTPA, superparamagnetic iron oxide nanoparticles, and 5-fluorouracil were encapsulated in nano- and microspheres composed of poly(D,L-lactide-co-glycolide), which was used as a model carrier. In vivo studies were performed with orthotopic xenograft of human breast cancer. The MR-based technique demonstrated here has enabled visualization of the delivery of carriers, and release and intratumoral distribution of the encapsulated positive contrast agent. This study demonstrated proof-of-principle results for the noninvasive monitoring of in vivo release and distribution profiles of MR contrast agents, and thus, this technique will make a great contribution to the field. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  16. Colorectal liver metastases: contrast agent diffusion coefficient for quantification of contrast enhancement heterogeneity at MR imaging.

    Science.gov (United States)

    Jia, Guang; O'Dell, Craig; Heverhagen, Johannes T; Yang, Xiangyu; Liang, Jiachao; Jacko, Richard V; Sammet, Steffen; Pellas, Theodore; Cole, Patricia; Knopp, Michael V

    2008-09-01

    To describe and determine the reproducibility of a simplified model to quantitatively measure heterogeneous intralesion contrast agent diffusion in colorectal liver metastases. This HIPAA-compliant retrospective study received institutional review board approval, and written informed consent was obtained from 14 patients (mean age, 61 years +/- 9 [standard deviation]; range, 41-78 years), including 10 men (mean age, 65 years +/- 8; range, 47-78 years) and four women (mean age, 54 years +/- 9; range, 41-59 years), with colorectal liver metastases. Magnetic resonance (MR) imaging was performed twice (first baseline MR image [B(1)] and second baseline MR image [B(2)]) in a single target lesion prior to therapy. Dynamic contrast material-enhanced MR imaging was performed by using a saturation-recovery fast gradient-echo sequence. A simplified contrast agent diffusion model was proposed, and a contrast agent diffusion coefficient (CDC) was calculated. The reproducibility of the CDC measurement was evaluated by using the Bland-Altman plot and a linear regression model. The mean CDC was 0.22 mm(2)/sec (range, 0.01-0.73 mm(2)/sec) on B(1) and 0.24 mm(2)/sec (range, 0.01-0.71 mm(2)/sec) on B(2), with an intraclass correlation coefficient of 0.91 (P < .0001). Bland-Altman plot showed good agreement, with a mean difference in measurement pairs of 0.017 mm(2)/sec +/- 0.096. The slope from the linear regression model was 0.89 (95% confidence interval: 0.63, 1.15) and the intercept was 0.01 (95% confidence interval: -0.08, 0.09). The CDC enables a quantitative description of contrast enhancement heterogeneity in lesions. Given the high reproducibility of the CDC metric, CDC appears promising for further qualification as an imaging biomarker of change measurement in response assessment. http://radiology.rsnajnls.org/cgi/content/full/248/3/901/DC1. RSNA, 2008

  17. Elemental imaging of MRI contrast agents: benchmarking of LA-ICP-MS to MRI

    Energy Technology Data Exchange (ETDEWEB)

    Pugh, J.A.T. [University of Sheffield, Centre for Analytical Sciences, Sheffield (United Kingdom); University of Sheffield, Department of Chemical and Biological Engineering, Sheffield (United Kingdom); Cox, A.G.; McLeod, C.W. [University of Sheffield, Centre for Analytical Sciences, Sheffield (United Kingdom); Bunch, J. [University of Birmingham, School of Chemistry, Birmingham (United Kingdom); Writer, M.J.; Hart, S.L. [UCL Institute of Child Health, Wolfson Centre for Gene Therapy of Childhood Disease, London (United Kingdom); Bienemann, A.; White, E. [University of Bristol, School of Clinical Sciences, Southmead Hospital, Bristol (United Kingdom); Bell, J. [Hammersmith Hospital, Metabolic and Molecular Imaging Group, MRC Clinical Sciences Centre, Imperial College London, London (United Kingdom)

    2012-06-15

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been used to map the spatial distribution of magnetic resonance imaging (MRI) contrast agents (Gd-based) in histological sections in order to explore synergies with in vivo MRI. Images from respective techniques are presented for two separate studies namely (1) convection enhanced delivery of a Gd nanocomplex (developmental therapeutic) into rat brain and (2) convection enhanced delivery, with co-infusion of Magnevist (commercial Gd contrast agent) and Carboplatin (chemotherapy drug), into pig brain. The LA technique was shown to be a powerful compliment to MRI not only in offering improved sensitivity, spatial resolution and signal quantitation but also in giving added value regarding the fate of administered agents (Gd and Pt agents). Furthermore simultaneous measurement of Fe enabled assignment of an anomalous contrast enhancement region in rat brain to haemorrhage at the infusion site. (orig.)

  18. Changes in Renal Function in Elderly Patients Following Intravenous Iodinated Contrast Administration: A Retrospective Study

    International Nuclear Information System (INIS)

    Alsafi, A.; Alsafi, Z.; Lakhani, A.; Strickland, N.H.

    2014-01-01

    Contrast-induced nephropathy (CIN) is a recognised complication of intravascular administration of iodinated contrast media (ICM). Previous studies suggest a higher incidence in the elderly, but no large study has assessed this to date. We set out to assess changes in creatinine in elderly inpatients following computed tomography (CT) examination and compare those who received intravenous contrast to those who did not. Methods. Using the Radiology Information System in two teaching hospitals, inpatients over the age of seventy who had a CT examination and a baseline creatinine were identified and their follow-up creatinine levels were analysed. Elderly inpatients who underwent a non contrast CT over the same period were used as controls. Results. 677 elderly inpatients who received ICM were compared with 487 controls. 9.2% of patients who received ICM developed acute kidney injury (AKI) compared to 3.5% of inpatient controls (Ρ<0.0001). Patients with higher baseline eGFR had a higher incidence of post-CT AKI. Conclusions. The incidence of post-CT AKI is higher in patients who received IV ICM compared to those who did not; the difference may be partly attributable to contrast-induced nephropathy. This suggests that the incidence of CIN in the elderly may not be as high as previously thought.

  19. Forearm Compartment Syndrome of a Newborn Associated with Extravasation of Contrast Agent

    Directory of Open Access Journals (Sweden)

    Egemen Altan

    2013-01-01

    Full Text Available Extravasation of contrast agents is a possible complication of imaging studies. Although extravasations typically cause minimal swelling or erythema, they can lead to compartment syndrome when the volume of extravasation is high. In this article, we will present an exceptional case where an insignificant amount of contrast agent extravasation led to a forearm compartment syndrome in a newborn, who was treated with an extended fasciotomy. We would like to emphasize the preventive techniques and treatment options of this iatrogenic complication in newborns. Close followup of the patient by the nurses, awareness of the parents and the personnel in the radiology department are the most important preventive measures in this extremity-threatening complication. Forearm compartment syndrome due to contrast agent extravasation may progress more rapidly in newborns even with smaller amounts of extravasation and prompt recognition of the pathology and immediate intervention are unevitable.

  20. Hexabrix (ioxaglate), a new low osmolality contrast agent for lumbar epidural double-catheter venography

    International Nuclear Information System (INIS)

    Meijenhorst, G.C.H.; Bruin, J.N.T. de

    1980-01-01

    Hexabrix (ioxaglate), a new low osmolality contrast agent, has been compared with Telebrix (ioxitalamate) in a series of 50 lumbar epidural venograms. The intensity of the pain and heat sensation experienced by the patient was significantly lower following the injection of Hexabrix. For this reason Hexabrix may be considered the contrast medium of choice for epidural venography. In 15 additional cases Hexabrix was compared with Amipaque (metrizamide) in the same iodine concentration (320 mg/ml). In these patients hardly any difference in pain and heat sensation was observed after the injection of both contrast agents. Frequently only a slight feeling of warmth was noticed. A minimal sensation of pain was occasionally observed to the same degree with both contrast agents. (orig.)

  1. Extracellular gadolinium contrast agents: Differences in stability

    International Nuclear Information System (INIS)

    Morcos, S.K.

    2008-01-01

    Extracellular gadolinium contrast agents (Gd-CA) are either linear or macrocyclic chelates available as ionic or non-ionic preparations. The molecular structure whether cyclic or linear and ionicity determines the stability of Gd-CA. Linear chelates are flexible open chains which do not offer a strong binding to Gd 3+ . In contrast, the macrocyclic chelates offer a strong binding to Gd 3+ by the virtue of being preorganized rigid rings of almost optimal size to cage the gadolinium atom. Non-ionic preparations are also less stable in comparison to the ionic ones as the binding between Gd 3+ with the negatively charged carboxyl groups is stronger in comparison to that with amides or alcohol in the non-ionic preparations. According to stability constants and kinetic measurements, the most stable Gd-CM is the ionic-macrocyclic chelate Gd-DOTA and the least stable agents are the non-ionic linear chelates gadodiamide and gadoversetamide. In vivo data confirmed the low stability of non-ionic linear chelates but no significant difference was observed amongst the macrocyclic agents whether ionic (Gd-DOTA) or non-ionic such as Gd-HP-DO3A and Gd-BT-DO3A. The stability of Gd-CA seems to be an important factor in the pathogenesis of the serious complication of nephrogenic systemic fibrosis. Gd-CA of low stability are likely to undergo transmetallation and release free Gd ions that deposit in tissue and attract circulating fibrocytes to initiate the process of fibrosis. No cases of NSF have been observed so far after the exclusive use of the stable macrocyclic Gd-CA

  2. Clinical application of a triombrin in urology, a new Soviet radiographic contrast agent

    International Nuclear Information System (INIS)

    Perel'man, V.M.

    1980-01-01

    A water-soluble radiographic contrast agent triombrin which is a methylglucosamine sodium salt mixture of diatrizoate was studied. The analysis is based on the observation of 175 patients subjected to 186 tests, mainly excretory urography with the double dose of the contrast agent. The correlation between the quality of the picture obtained and the individual features of the patients has been established. Assessment of urograms obtained with the use of hypaque, urografin, verografin, urotrast and triombrin has revealed results similar to those with triombrin. Allergic reactions and complications have been noted in 23 (14%) of 164 patients after excretory and infusion urography. Satisfactory contrast and a good tolerance of the agent allowed recommending triombrin for wide use in medical practice

  3. Preclinical Studies of a Kidney Safe Iodinated Contrast Agent.

    Science.gov (United States)

    Rowe, Elizabeth S; Rowe, Vernon D; Biswas, Sangita; Mosher, Gerold; Insisienmay, Lovella; Ozias, Marlies K; Gralinski, Michael R; Hunter, John; Barnett, James S

    2016-09-01

    Contrast-induced acute kidney injury (CI-AKI) is a serious complication of the use of iodinated contrast agents. This problem is particularly acute in interventional neurology and interventional cardiology, probably due to the intra-arterial route of injection, high contrast volumes, and preexisting risk factors of these patients. In an attempt to develop a contrast agent that is less damaging to the kidneys, we have studied the effects of adding a small amount of the substituted cyclodextrin, sulfobutyl-ether-β-cyclodextrin (SBECD), to iohexol in rodent models of renal toxicity. Renally compromised mice and rats were injected with iohexol and iohexol-SBECD via the tail vein. The renal pathology, creatinine clearance, and survival benefits of iohexol-SBECD were studied. The safety of direct intra-arterial injection of the iohexol-SBECD formulation was studied in a dog heart model system. Mechanism of action studies in cell culture model using a human kidney cell line was performed using flow cytometry. Nephrotoxicity was significantly reduced using iohexol-SBECD compared to iohexol alone, at mole ratios of iohexol:SBECD of 1:0.025. SBECD increased survival from 50% to 88% in a rat survival study. In the dog heart model, iohexol-SBECD was safe. Cell culture studies suggest that SBECD interferes with the early stages of contrast-induced apoptosis in a human renal cell line. We have shown that the addition of a small amount of SBECD (one molecule of SBECD per 40 iohexol molecules) significantly protects rodent kidneys from CI-AKI. Further development of this new formulation of iodinated contrast is warranted. © 2016 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  4. Biofilm imaging in porous media by laboratory X-Ray tomography: Combining a non-destructive contrast agent with propagation-based phase-contrast imaging tools.

    Science.gov (United States)

    Carrel, Maxence; Beltran, Mario A; Morales, Verónica L; Derlon, Nicolas; Morgenroth, Eberhard; Kaufmann, Rolf; Holzner, Markus

    2017-01-01

    X-ray tomography is a powerful tool giving access to the morphology of biofilms, in 3D porous media, at the mesoscale. Due to the high water content of biofilms, the attenuation coefficient of biofilms and water are very close, hindering the distinction between biofilms and water without the use of contrast agents. Until now, the use of contrast agents such as barium sulfate, silver-coated micro-particles or 1-chloronaphtalene added to the liquid phase allowed imaging the biofilm 3D morphology. However, these contrast agents are not passive and potentially interact with the biofilm when injected into the sample. Here, we use a natural inorganic compound, namely iron sulfate, as a contrast agent progressively bounded in dilute or colloidal form into the EPS matrix during biofilm growth. By combining a very long source-to-detector distance on a X-ray laboratory source with a Lorentzian filter implemented prior to tomographic reconstruction, we substantially increase the contrast between the biofilm and the surrounding liquid, which allows revealing the 3D biofilm morphology. A comparison of this new method with the method proposed by Davit et al (Davit et al., 2011), which uses barium sulfate as a contrast agent to mark the liquid phase was performed. Quantitative evaluations between the methods revealed substantial differences for the volumetric fractions obtained from both methods. Namely, contrast agent-biofilm interactions (e.g. biofilm detachment) occurring during barium sulfate injection caused a reduction of the biofilm volumetric fraction of more than 50% and displacement of biofilm patches elsewhere in the column. Two key advantages of the newly proposed method are that passive addition of iron sulfate maintains the integrity of the biofilm prior to imaging, and that the biofilm itself is marked by the contrast agent, rather than the liquid phase as in other available methods. The iron sulfate method presented can be applied to understand biofilm development

  5. Contrast-enhanced MRI of the lung

    International Nuclear Information System (INIS)

    Kauczor, Hans-Ulrich; Kreitner, Karl-Friedrich

    2000-01-01

    The lung has long been neglected by MR imaging. This is due to unique intrinsic difficulties: (1) signal loss due to cardiac pulsation and respiration; (2) susceptibility artifacts caused by multiple air-tissue interfaces; (3) low proton density. There are many MR strategies to overcome these problems. They consist of breath-hold imaging, respiratory and cardiac gating procedures, use of short repetition and echo times, increase of the relaxivity of existing spins by administration of intravenous contrast agents, and enrichment of spin density by hyperpolarized noble gases or oxygen. Improvements in scanner performance and frequent use of contrast media have increased the interest in MR imaging and MR angiography of the lung. They can be used on a routine basis for the following indications: characterization of pulmonary nodules, staging of bronchogenic carcinoma, in particular assessment of chest wall invasion; evaluation of inflammatory activity in interstitial lung disease; acute pulmonary embolism, chronic thromboembolic pulmonary hypertension, vascular involvement in malignant disease; vascular abnormalities. Future perspectives include perfusion imaging using extracellular or intravascular (blood pool) contrast agents and ventilation imaging using inhalation of hyperpolarized noble gases, of paramagnetic oxygen or of aerosolized contrast agents. These techniques represent new approaches to functional lung imaging. The combination of visualization of morphology and functional assessment of ventilation and perfusion is unequalled by any other technique

  6. Biological in situ characterization of polymeric microbubble contrast agents

    NARCIS (Netherlands)

    Wan, Sha; Egri, Gabriella; Oddo, Letizia; Cerroni, Barbara; Dähne, Lars; Paradossi, Gaio; Salvati, Anna; Lynch, Iseult; Dawson, Kenneth A; Monopoli, Marco P

    Polymeric microbubbles (MBs) are gas filled particles composed of a thin stabilized polymer shell that have been recently developed as valid contrast agents for the combined use of ultrasonography (US), magnetic resonance imaging (MRI) and single photon emission computer tomography (SPECT) imaging.

  7. Counterbalancing the use of ultrasound contrast agents by a cavitation-regulated system.

    Science.gov (United States)

    Desjouy, C; Fouqueray, M; Lo, C W; Muleki Seya, P; Lee, J L; Bera, J C; Chen, W S; Inserra, C

    2015-09-01

    The stochastic behavior of cavitation can lead to major problems of initiation and maintenance of cavitation during sonication, responsible of poor reproducibility of US-induced bioeffects in the context of sonoporation for instance. To overcome these disadvantages, the injection of ultrasound contrast agents as cavitation nuclei ensures fast initiation and lower acoustic intensities required for cavitation activity. More recently, regulated-cavitation devices based on the real-time modulation of the applied acoustic intensity have shown their potential to maintain a stable cavitation state during an ultrasonic shot, in continuous or pulsed wave conditions. In this paper is investigated the interest, in terms of cavitation activity, of using such regulated-cavitation device or injecting ultrasound contrast agents in the sonicated medium. When using fixed applied acoustic intensity, results showed that introducing ultrasound contrast agents increases reproducibility of cavitation activity (coefficient of variation 62% and 22% without and with UCA, respectively). Moreover, the use of the regulated-cavitation device ensures a given cavitation activity (coefficient of variation less 0.4% in presence of UCAs or not). This highlights the interest of controlling cavitation over time to free cavitation-based application from the use of UCAs. Interestingly, during a one minute sonication, while ultrasound contrast agents progressively disappear, the regulated-cavitation device counterbalance their destruction to sustain a stable inertial cavitation activity. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. The use of innovative gadolinium-based contrast agent for MR-diagnosis of cancer in the experiment

    International Nuclear Information System (INIS)

    Chernov, V; Medvedeva, A; Sinilkin, I; Zelchan, R; Grigorev, E; Frolova, I; Nam, I

    2016-01-01

    The present study of the functional suitability and specific activity of the contrast agent gadolinium-based for magnetic resonance imaging demonstrated that the investigated contrast agent intensively accumulates in organs and anatomical structures of the experimental animals. In the model of tumor lesions in animals, study have shown that investigational contrast agent accumulates in the tumor tissue and retained there in for a long enough time. (paper)

  9. Multiphase CT scanning and different intravenous contrast media concentrations in combined F-18-FDG PET/CT: Effect on quantitative and clinical assessment

    Energy Technology Data Exchange (ETDEWEB)

    Rebiere, Marilou, E-mail: Marilou.Rebiere@rwth-aachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Verburg, Frederik A., E-mail: fverburg@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Nuclear Medicine, Maastricht University Medical Center, P. Debeylaan 25, 6202 AZ Maastricht (Netherlands); Palmowski, Moritz, E-mail: mpalmowski@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Radiology, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Experimental Molecular Imaging, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Krohn, Thomas, E-mail: tkrohn@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Pietsch, Hubertus, E-mail: hubertus.pietsch@bayer.com [Contrast Media Research, Bayer Pharma AG, Muellerstr. 178, 13353 Berlin (Germany); Kuhl, Christiane K., E-mail: ckuhl@ukaachen.de [Department of Radiology, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Mottaghy, Felix M., E-mail: fmottaghy@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Nuclear Medicine, Maastricht University Medical Center, P. Debeylaan 25, 6202 AZ Maastricht (Netherlands); Behrendt, Florian F., E-mail: fbehrendt@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany)

    2012-08-15

    Purpose: To evaluate the influence of multiphase CT scanning and different intravenous contrast media on contrast enhancement, attenuation correction and image quality in combined PET/CT. Material and methods: 140 patients were prospectively enrolled for F-18-FDG-PET/CT including a low-dose unenhanced, arterial and venous contrast enhanced CT. The first (second) 70 patients, received contrast medium with 370 (300) mg iodine/ml. The iodine delivery rate (1.3 mg/s) and total iodine load (44.4 g) were identical for both groups. Contrast enhancement and maximum and mean standardized FDG uptake values (SUVmax and SUVmean) were determined for the un-enhanced, arterial and venous PET/CT at multiple anatomic sites and PET reconstructions were visually evaluated. Results: Arterial contrast enhancement was significantly higher for the 300 mg/ml contrast medium compared to 370 mg I/ml at all anatomic sites. Venous enhancement was not different between the two contrast media. SUVmean and SUVmax were significantly higher for the contrast enhanced compared to the non-enhanced PET/CT at all anatomic sites (all P < 0.001). Tracer uptake was significantly higher in the arterial than in the venous PET/CT in the arteries using both contrast media (all P < 0.001). No differences in tracer uptake were found between the contrast media (all P > 0.05). Visual assessment revealed no relevant differences between the different PET reconstructions. Conclusions: There is no relevant qualitative influence on the PET scan from the use of different intravenous contrast media in its various phases in combined multiphase PET/CT. For quantitative analysis of tracer uptake it is required to use an identical PET/CT protocol.

  10. Biocompatible KMnF3 nanoparticular contrast agent with proper plasma retention time for in vivo magnetic resonance imaging.

    Science.gov (United States)

    Liu, Zhi-jun; Song, Xiao-xia; Xu, Xian-zhu; Tang, Qun

    2014-04-18

    Nanoparticular MRI contrast agents are rapidly becoming suitable for use in clinical diagnosis. An ideal nanoparticular contrast agent should be endowed with high relaxivity, biocompatibility, proper plasma retention time, and tissue-specific or tumor-targeting imaging. Herein we introduce PEGylated KMnF3 nanoparticles as a new type of T1 contrast agent. Studies showed that the nanoparticular contrast agent revealed high bio-stability with bovine serum albumin in PBS buffer solution, and presented excellent biocompatibility (low cytotoxicity, undetectable hemolysis and hemagglutination). Meanwhile the new contrast agent possessed proper plasma retention time (circulation half-life t1/2 is approximately 2 h) in the body of the administrated mice. It can be delivered into brain vessels and maintained there for hours, and is mostly cleared from the body within 48 h, as demonstrated by time-resolved MRI and Mn-biodistribution analysis. Those distinguishing features make it suitable to obtain contrast-enhanced brain magnetic resonance angiography. Moreover, through the process of passive targeting delivery, the T1 contrast agent clearly illuminates a brain tumor (glioma) with high contrast image and defined shape. This study demonstrates that PEGylated KMnF3 nanoparticles represent a promising biocompatible vascular contrast agent for magnetic resonance angiography and can potentially be further developed into an active targeted tumor MRI contrast agent.

  11. The impact of injector-based contrast agent administration in time-resolved MRA.

    Science.gov (United States)

    Budjan, Johannes; Attenberger, Ulrike I; Schoenberg, Stefan O; Pietsch, Hubertus; Jost, Gregor

    2018-05-01

    Time-resolved contrast-enhanced MR angiography (4D-MRA), which allows the simultaneous visualization of the vasculature and blood-flow dynamics, is widely used in clinical routine. In this study, the impact of two different contrast agent injection methods on 4D-MRA was examined in a controlled, standardized setting in an animal model. Six anesthetized Goettingen minipigs underwent two identical 4D-MRA examinations at 1.5 T in a single session. The contrast agent (0.1 mmol/kg body weight gadobutrol, followed by 20 ml saline) was injected using either manual injection or an automated injection system. A quantitative comparison of vascular signal enhancement and quantitative renal perfusion analyses were performed. Analysis of signal enhancement revealed higher peak enhancements and shorter time to peak intervals for the automated injection. Significantly different bolus shapes were found: automated injection resulted in a compact first-pass bolus shape clearly separated from the recirculation while manual injection resulted in a disrupted first-pass bolus with two peaks. In the quantitative perfusion analyses, statistically significant differences in plasma flow values were found between the injection methods. The results of both qualitative and quantitative 4D-MRA depend on the contrast agent injection method, with automated injection providing more defined bolus shapes and more standardized examination protocols. • Automated and manual contrast agent injection result in different bolus shapes in 4D-MRA. • Manual injection results in an undefined and interrupted bolus with two peaks. • Automated injection provides more defined bolus shapes. • Automated injection can lead to more standardized examination protocols.

  12. Contrast Agent-Enhanced Computed Tomography of Articular Cartilage: Association with Tissue Composition and Properties

    International Nuclear Information System (INIS)

    Silvast, T. S.; Jurvelin, J.S.; Aula, A.S.; Lammi, M.J.; Toeyraes, J.

    2009-01-01

    Background: Contrast agent-enhanced computed tomography may enable the noninvasive quantification of glycosaminoglycan (GAG) content of articular cartilage. It has been reported that penetration of the negatively charged contrast agent ioxaglate (Hexabrix) increases significantly after enzymatic degradation of GAGs. However, it is not known whether spontaneous degradation of articular cartilage can be quantitatively detected with this technique. Purpose: To investigate the diagnostic potential of contrast agent-enhanced cartilage tomography (CECT) in quantification of GAG concentration in normal and spontaneously degenerated articular cartilage by means of clinical peripheral quantitative computed tomography (pQCT). Material and Methods: In this in vitro study, normal and spontaneously degenerated adult bovine cartilage (n=32) was used. Bovine patellar cartilage samples were immersed in 21 mM contrast agent (Hexabrix) solution for 24 hours at room temperature. After immersion, the samples were scanned with a clinical pQCT instrument. From pQCT images, the contrast agent concentration in superficial as well as in full-thickness cartilage was calculated. Histological and functional integrity of the samples was quantified with histochemical and mechanical reference measurements extracted from our earlier study. Results: Full diffusion of contrast agent into the deep cartilage was found to take over 8 hours. As compared to normal cartilage, a significant increase (11%, P 0.5, P<0.01). Further, pQCT could be used to measure the thickness of patellar cartilage. Conclusion: The present results suggest that CECT can be used to diagnose proteoglycan depletion in spontaneously degenerated articular cartilage with a clinical pQCT scanner. Possibly, the in vivo use of clinical pQCT for CECT arthrography of human joints is feasible

  13. The influence of upper limb position on the effect of a contrast agent in chest CT enhancement

    International Nuclear Information System (INIS)

    Feng, Shi-Ting; Wang, Meng; Gao, Zhenhua; Tan, Guosheng; Cai, Huasong; Hu, Xiaoshu; Yang, Jianyong; Li, Zi-Ping

    2013-01-01

    Purpose: To compare the influence of two different upper limb positions on contrast agent effects in chest CT enhancement. Materials and methods: In 142 patients undergoing contrast-enhanced CT chest scanning, an indwelling venous catheter was placed in the right hand and iodinated contrast agent was injected through a high-pressure single syringe pump. The patients were divided into three age groups (<40 years; 40–60 years; and >60 years) and randomly assigned to one of two upper limb position groups: (1) supine position, both upper limbs extended and raised above head in the same horizontal plane as the body; and (2) supine position, both upper limbs raised and crossed on the forehead, with the right arm on top. Differences in mean CT values on the two sides of the thoracic inlet along the right subclavian vein were used to evaluate the effects of the contrast agent. Results: Although contrast agent effects were not significantly different among the three age groups with either limb position, there was a significant difference between patients adopting the second limb positions (Chi-square value was 5.936, P < 0.05). An excellent or good contrast agent effect was observed in 63.08% of patients assuming the first limb position, as compared with 81.69% assuming the second position. Conclusion: For contrast-enhanced CT chest scans, use of the second limb position can reduce retention of the contrast agent in the right axillary vein and the right subclavian vein outside the thorax, increase contrast agent utilization, and decrease artifacts caused by high-density, local retention of the contrast agent

  14. Early detection of osteoarthritis in rabbits using MRI with a double-contrast agent.

    Science.gov (United States)

    Onishi, Okihiro; Ikoma, Kazuya; Kido, Masamitsu; Kabuto, Yukichi; Ueshima, Keiichiro; Matsuda, Ken-Ichi; Tanaka, Masaki; Kubo, Toshikazu

    2018-03-13

    Articular cartilage degeneration has been evaluated by magnetic resonance imaging (MRI). However, this method has several problems, including its time-consuming nature and the requirement of a high magnetic field or specialized hardware. The purpose of this study was to sequentially assess early degenerative changes in rabbit knee articular cartilage using MRI with a new double-contrast agent. We induced osteoarthritis (OA) in the right knee of rabbits by anterior cruciate ligament transection and partial medial meniscectomy. Proton density-weighted images and T 2 -calculated images were obtained before and after contrast agent injection into the knee. The signal intensity ratio (SIR) values on the proton density-weighted images were calculated by dividing the signal intensity of the articular cartilage by that of joint fluid. Six rabbits were examined using MRI at 2 (designated 2-w OA) and 4 weeks (4-w OA) after the operation. Histological examination was performed 4 weeks after the operation. One rabbit was histologically examined 2 weeks after the operation. The control consisted of six rabbits that were not subjected to the operation. The SIR values, T 2 values and the thicknesses of the cartilage of the 2-w OA, 4-w OA and the control before and after contrast agent injection were analyzed. The Mankin score and OARSI (Osteoarthritis Research Society International) score were used for the histological evaluation. Significant differences in the SIR and T 2 values of the medial and lateral condyles of the femur were found between the control and the 4-w OA only after contrast agent injection. No significant differences were found in the SIR and T 2 values before contrast agent injection between the control, the 2-w OA and 4-w OA. The thickness of the articular cartilage revealed no significant differences. In the histological assessment, the Mankin score and OARSI score sequentially increased from the control to the 4-w OA. We evaluated the SIR and T 2 values

  15. Adverse reactions to iotroxate at intravenous cholangiography

    International Nuclear Information System (INIS)

    Nilsson, U.

    1987-01-01

    The number and type of adverse reactions to meglumine iotroxate at intravenous infusion cholangiography, performed one day prior to elective cholecystectomy, were recorded in a prospective investigation of 196 asymptomatic, anicteric patients. One hundred ml (50 mg I/ml) of contrast medium was infused over a period of 30 minutes. Only 2 minor (1%) and no severe or fatal reactions were noted. A review of the literature on the use of iotroxate in 2492 patients, including those in the present investigation, revealed a complication rate of 3.5% (3.0% minor, 0.3% moderate and 0.2% severe reactions) at infusion of iotroxate (5.0-8.0 g I) over a period of 30 to 120 minutes. This compared favourably with the 5% complication rate (4% minor, 0.5% moderate and 0.5% severe reactions) at infusion of iodoxamate and the 9% complication rate (5% minor, 1% moderate and 3% severe reactions) at infusion of ioglycamide. Irrespective of the contrast agent used, the frequency of adverse reactions at infusion was found to be 3 times lower than when equal amounts (5.0-5.6 g I) of the same medium were injected. It is concluded that, at present, infusion of iotroxate in an amount which approximates to the transportation maximum of the liver is the least toxic way of performing intravenous cholangiography with an optimum filling of the bile ducts. (orig.)

  16. Contrast induced nephropathy in patients undergoing intravenous (IV) contrast enhanced computed tomography (CECT) and the relationship with risk factors: A meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Moos, Shira I., E-mail: s.i.moos@amc.uva.nl; Vemde, David N.H. van; Stoker, Jaap; Bipat, Shandra

    2013-09-15

    Purpose: To summarize the incidence of contrast-induced nephropathy (CIN) and associations between CIN incidence and risk factors in patients undergoing intravenous contrast-enhanced computed tomography (CECT) with low- or iso-osmolar iodinated contrast medium. Methods: This review is performed in accordance with the preferred reporting items in systematic reviews and meta-analysis (PRISMA) guidelines. We searched the MEDLINE, EMBASE and Cochrane databases from 2002 till November 2012. Two reviewers included papers and extracted data. The pooled data were analysed by either fixed or random-effects approach depending on heterogeneity defined as the I{sup 2} index. Results: 42 articles with 18,790 patients (mean age 61.5 years (range: 38–83 years)) were included. The mean baseline eGFR was 59.8 mL/min and ranged from 4 to 256 mL/min. Of all patients 45.0% had an estimated glomerular filtration rate (eGFR) < 60 mL/min, 55.2% had hypertension; 20.2% had diabetes mellitus (DM) and 6.5% had congestive heart failure (CHF). The overall pooled CIN incidence, defined as a SCr increase of ≥25% or ≥0.5 mg/dL, was 4.96% (95%CI: 3.79–6.47). Data analysis showed associations between CIN and the presence of renal insufficiency, DM, malignancy, age > 65 years and use of non-steroidal anti-inflammatory drugs (NSAID's) with odds ratios of 1.73 (95%CI: 1.06–2.82), 1.87 (95%CI: 1.55–2.26), 1.79 (95%CI: 1.03–3.11), 1.95 (95%CI: 1.02–3.70) and 2.32 (95%CI: 1.04–5.19), respectively while hypertension, anaemia and CFH were not associated (p = 0.13, p = 0.38, p = 0.40). Conclusion: The mean incidence of CIN after intravenous iodinated CECT was low and associated with renal insufficiency, diabetes, presence of malignancy, old age and NSAID's use.

  17. High spatial resolution and high contrast visualization of brain arteries and veins. Impact of blood pool contrast agent and water-selective excitation imaging at 3T

    International Nuclear Information System (INIS)

    Spuentrup, E.; Jacobs, J.E.; Kleimann, J.F.

    2010-01-01

    Purpose: To investigate a blood pool contrast agent and water-selective excitation imaging at 3 T for high spatial and high contrast imaging of brain vessels including the veins. Methods and Results: 48 clinical patients (47 ± 18 years old) were included. Based on clinical findings, twenty-four patients received a single dose of standard extracellular Gadoterate-meglumine (Dotarem registered ) and 24 received the blood pool contrast agent Gadofosveset (Vasovist registered ). After finishing routine MR protocols, all patients were investigated with two high spatial resolution (0.15 mm 3 voxel size) gradient echo sequences in random order in the equilibrium phase (steady-state) as approved by the review board: A standard RF-spoiled gradient-echo sequence (HR-SS, TR/TE 5.1 / 2.3 msec, FA 30 ) and a fat-suppressed gradient-echo sequence with water-selective excitation (HR-FS, 1331 binominal-pulse, TR/TE 8.8 / 3.8 msec, FA 30 ). The images were subjectively assessed (image quality with vessel contrast, artifacts, depiction of lesions) by two investigators and contrast-to-noise ratios (CNR) were compared using the Student's t-test. The image quality and CNR in the HR-FS were significantly superior compared to the HR-SS for both contrast agents (p < 0.05). The CNR was also improved when using the blood pool agent but only to a minor extent while the subjective image quality was similar for both contrast agents. Conclusion: The utilized sequence with water-selective excitation improved image quality and CNR properties in high spatial resolution imaging of brain arteries and veins. The used blood pool contrast agent improved the CNR only to a minor extent over the extracellular contrast agent. (orig.)

  18. An experimental study on tissue reaction of various contrast agents on mediastinum

    International Nuclear Information System (INIS)

    Chung, Jin Wook; Kim, Hyung Jin; Kim, Seung Hyup; Park, Jae Hyung; Chang, Kee Hyun

    1989-01-01

    Till now, there is no consensus about appropriate contrast agents for use in clinical investigation in suspected perforation of the esophagus. Gastrografin, most widely used water soluble contrast agent, is less sensitive in detection of fistulous tract and can induce pulmonary edema, leading to death occasionally, if aspirated. Barium sulphate has been contraindicated without actual evaluation of its effect on mediastinum by experimental and clinical study. The purpose of this experimental study is to evaluate the type of tissue reaction and its severity in mediastinum and, as a result, to propose appropriate contrast agents in various clinical situations of suspected esophageal leakage. Barium sulphate, Hytrat, Gastrografin, Telebrix, Hexabrix, Amipaque, Niopam, and Ultravist were injected into mediastinum of 20 rats in each. The tissue reaction of injection sites were examined microscopically and graded according severity of inflammatory reaction with serial follow up from 1 day to 8 weeks after injection. The results are as follows, 1. Barium sulphate and Hytrast produced highly significant (p<0.01) tissue reaction compared to saline group and early inflammatory reaction was more severe in Hytrast. 2. Water soluble agents produced no significant reaction in mediastinum compared to saline control group and proved to be safe in the situation of leakage into mediastinum. 3. Injected barium caused no death during 8 week follow up in spite of large injected amount and histologically produced localized indolent granuloma after 4 weeks which is expected not to cause any delayed complications. In consideration of above results, superior physical characteristics of barium sulphate and drawbacks of Gastrografin, we concluded as follows. 1. For postoperative assessment of esophageal anastomosis, Barium sulphate is the contrast agent of choice

  19. Micro-radiography of biological samples with medical contrast agents

    International Nuclear Information System (INIS)

    Dammer, J.; Weyda, F.; Benes, J.; Sopko, V.; Gelbic, I.

    2013-01-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system

  20. Micro-radiography of biological samples with medical contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J., E-mail: jiri.dammer@lf1.cuni.cz [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Weyda, F. [Faculty of Science, University of South Bohemia, Branisovska 31, 370 05 Ceske Budejovice (Czech Republic); Benes, J. [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Sopko, V. [Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Gelbic, I. [Biology Centre, AS CR, Institute of Entomology, Department of Biochemistry and Physiology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic)

    2013-12-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system.

  1. Spectral Imaging Technology-Based Evaluation of Radiation Treatment Planning to Remove Contrast Agent Artifacts.

    Science.gov (United States)

    Yi-Qun, Xu; Wei, Liu; Xin-Ye, Ni

    2016-10-01

    This study employs dual-source computed tomography single-spectrum imaging to evaluate the effects of contrast agent artifact removal and the computational accuracy of radiotherapy treatment planning improvement. The phantom, including the contrast agent, was used in all experiments. The amounts of iodine in the contrast agent were 30, 15, 7.5, and 0.75 g/100 mL. Two images with different energy values were scanned and captured using dual-source computed tomography (80 and 140 kV). To obtain a fused image, 2 groups of images were processed using single-energy spectrum imaging technology. The Pinnacle planning system was used to measure the computed tomography values of the contrast agent and the surrounding phantom tissue. The difference between radiotherapy treatment planning based on 80 kV, 140 kV, and energy spectrum image was analyzed. For the image with high iodine concentration, the quality of the energy spectrum-fused image was the highest, followed by that of the 140-kV image. That of the 80-kV image was the worst. The difference in the radiotherapy treatment results among the 3 models was significant. When the concentration of iodine was 30 g/100 mL and the distance from the contrast agent at the dose measurement point was 1 cm, the deviation values (P) were 5.95% and 2.20% when image treatment planning was based on 80 and 140 kV, respectively. When the concentration of iodine was 15 g/100 mL, deviation values (P) were -2.64% and -1.69%. Dual-source computed tomography single-energy spectral imaging technology can remove contrast agent artifacts to improve the calculated dose accuracy in radiotherapy treatment planning. © The Author(s) 2015.

  2. Novel route synthesis of porous and solid gold nanoparticles for investigating their comparative performance as contrast agent in computed tomography scan and effect on liver and kidney function

    Directory of Open Access Journals (Sweden)

    Aziz F

    2017-02-01

    Full Text Available Farooq Aziz,1,2 Ayesha Ihsan,1 Aalia Nazir,2 Ishaq Ahmad,3 Sadia Zafar Bajwa,1 Asma Rehman,1 Abdoulaye Diallo,4 Waheed S Khan1 1Nanobiotechnology Group, National Institute for Biotechnology and Genetic Engineering (NIBGE, Faisalabad, 2Department of Physics, Islamia University of Bahawalpur, Bahawalpur, 3National Center for Physics, Quaid-I-Azam University, Islamabad, Pakistan; 4Laboratory of Photonics and Nano-Fabrication, Faculty of Science and Technology, Cheikh Anta Diop University of Dakar (UCAD, Dakar-Fann Dakar, Senegal Abstract: Gold nanoparticles (GNPs with dimension in the range of 1–100 nm have a prominent role in a number of biomedical applications like imaging, drug delivery, and cancer therapy owing to their unique optical features and biocompatibility. In this work, we report a novel technique for the synthesis of two types of GNPs namely porous gold nanoparticles (PGNPs and solid gold nanoparticles (SGNPs. PGNPs of size 35 nm were fabricated by reduction of gold (III solution with lecithin followed by addition of L-ascorbic acid and tri-sodium citrate, whereas SGNPs with a dimension of 28 nm were prepared by reflux method using lecithin as a single reducing agent. Comparative studies using PGNPs (λmax 560 nm and SGNPs (λmax 548 nm were conducted for evaluating their use as a contrast agent. These studies reveled that in direct computed tomography scan, PGNPs exhibited brighter contrast (45 HU than SGNPs (26 HU. To investigate the effect of PGNPs and SGNPs on the liver and kidney profile, male rabbits were intravenously injected with an equal dose of 1 mg/kg weight of PGNPs and SGNPs. The effect on biochemical parameters was evaluated 72 hours after intravenous (IV injection including liver function profile, renal (kidney function biomarker, random blood glucose value, and cholesterol level. During one comparison of contrast in CT scan, PGNPs showed significantly enhanced contrast in whole-rabbit and organ CT scan as

  3. Transthoracic contrast echocardiography using vitamin B6 and sodium bicarbonate as contrast agents for the diagnosis of patent foramen ovale.

    Science.gov (United States)

    He, Jiang-Chun; Zheng, Jian-Yong; Li, Xin; Yang, Ye; Zhang, Bo-Yang; Chen, Yu; Li, Xian-Feng; Liu, Ying-Ming; Cao, Yi; Zhao, Li; Li, Tian-Chang

    2017-08-01

    To evaluate the utility of transthoracic contrast echocardiography (cTTE) using vitamin B6 and sodium bicarbonate as contrast agents for diagnosing right-to-left shunt (RLS) caused by patent foramen ovale (PFO) compared to that of transesophageal echocardiography (TEE). We investigated 125 patients admitted to our neurology department with unexplained cerebral infarction and migraine. All patients underwent cTTE using vitamin B6 and sodium bicarbonate as contrast agents, after which they underwent transthoracic echocardiography. The Doppler signal was recorded during the Valsalva maneuver, and TEE examinations were performed. The feasibility, diagnostic sensitivity, and safety of cTTE and TEE for PFO recognition were compared. Evidence of PFO was found in 49 (39.20%) patients with cTTE, more than were detected with TEE (39, 31.20%) (χ 2 =5.0625, P=0.0244). cTTE had a sensitivity of 92.31% and a specificity of 84.88% for diagnosing PFO, showing high concordance with TEE for PFO recognition (κ=0.72). Further, results of a semi-quantitative evaluation of PFO-RLS by cTTE were better than those with TEE (Z=-2.011, P=0.044). No significant adverse reaction was discovered during cTTE examination. cTTE using vitamin B6 and sodium bicarbonate as contrast agents has relatively good sensitivity and specificity for diagnosing RLS caused by PFO when compared with those for TEE. Using vitamin B6 and sodium bicarbonate as contrast agents to perform cTTE is recommended for detecting and diagnosing the PFO due to its simplicity, non-invasive character, low cost, and high feasibility.

  4. Toxicity evaluation of Gd2O3@SiO2 nanoparticles prepared by laser ablation in liquid as MRI contrast agents in vivo

    Directory of Open Access Journals (Sweden)

    Tian XM

    2014-08-01

    Full Text Available Xiumei Tian,1,* Fanwen Yang,1,* Chuan Yang,2 Ye Peng,1 Dihu Chen,3 Jixiang Zhu,1 Fupo He,1 Li Li,2 Xiaoming Chen11Department of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong Province, People’s Republic of China; 2State Key Laboratory of Oncology in South China, Imaging Diagnosis and Interventional Center, Sun Yat-sen University Cancer Center, Guangzhou, Guangdong Province, People’s Republic of China; 3State Key Laboratory of Optoelectronic Materials and Technologies, School of Physics and Engineering, Sun Yat-Sen University, Guangzhou, Guangdong Province, People’s Republic of China*These authors contributed equally to this workAbstract: Poor toxicity characterization is one obstacle to the clinical deployment of Gd2O3@SiO2 core-shell nanoparticles (Gd-NPs for use as magnetic resonance (MR imaging contrast agents. To date, there is no systematic toxicity data available for Gd-NPs prepared by laser ablation in liquid. In this article, we systematically studied the Gd-NPs’ cytotoxicity, apoptosis in vitro, immunotoxicity, blood circulation half-life, biodistribution and excretion in vivo, as well as pharmacodynamics. The results show the toxicity, and in vivo MR data show that these NPs are a good contrast agent for preclinical applications. No significant differences were found in cell viability, apoptosis, and immunotoxicity between our Gd-NPs and Gd in a DTPA (diethylenetriaminepentaacetic acid chelator. Biodistribution data reveal a greater accumulation of the Gd-NPs in the liver, spleen, lung, and tumor than in the kidney, heart, and brain. Approximately 50% of the Gd is excreted via the hepatobiliary system within 4 weeks. Furthermore, dynamic contrast-enhanced T1-weighted MR images of xenografted murine tumors were obtained after intravenous administration of the Gd-NPs. Collectively, the single step preparation of Gd-NPs by laser ablation in liquid produces particles with satisfactory cytotoxicity

  5. Study on the effects of six intravenous anesthetic agents on regional ventricular function in dogs (thiopental, etomidate, propofol, fentanyl, sufentanil, alfentanil)

    NARCIS (Netherlands)

    de Hert, S. G.

    1991-01-01

    This study evaluates the effects of 30 min increasing doses infusions of six intravenous anesthetic agents (thiopental, etomidate, propofol, fentanyl, sufentanil and alfentanil) on regional ventricular function in a normal and an acute ischemic heart segment in dogs. Part 1 discusses the methodology

  6. Intravenous coronary angiography utilizing K-emission and bremsstrahlung X-rays produced by electron bombardment

    International Nuclear Information System (INIS)

    1992-01-01

    The screening of the general population for coronary artery disease would be practical if a method existed for visualizing the extent of occlusion after an intravenous injection of contrast agent. Measurements performed with synchrotron radiation at SSRL and NSLS have shown that such an intravenous angiography procedure would be possible with an intense source of monochromatic X-rays. Because of the high cost of an electron synchrotron, theoretical analysis and experiments using inanimate phantoms has been undertaken to demonstrate the feasibility of using the spectrum produced by two appropriately chosen anode materials when bombarded with electrons in the 100--500 keV energy range for angiography. By using the X-rays emitted at 120 degree to the incident electron direction, about 20--30% of the X-ray intensity would be due to K-emission lines. Calculations using the TIGERP Monte Carlo Code, have shown that high quality angiograms of human coronary arteries should be possible with a contrast agent containing ytterbium, if an electron beam pulses of 16 kJ were used for each anode target. The experimental program supported in part by the DOE has consisted of these theoretical calculations and experiments at the Dynamitron Electron Accelerator Facility at BNL

  7. Oral gadopentetate dimeglumine administration as a negative gastrointestinal contrast agent to improve image quality of MR cholangiopancreatography

    International Nuclear Information System (INIS)

    Chen Yi; Xu Yikai; Zhao Yuhui; Wang Guisheng

    2008-01-01

    Objective: To choose optimal concentration and volume of Gd-DTPA solution as a oral gastrointestinal negative contrast agent for MRCP. To evaluate the role of Gd-DTPA solution in improving image quality of MRCP. Methods: In vitro experiment: Gd-DTPA solution was made with different concentrations. T 1 WI, T 2 WI, two-dimensional single slice fast spin echo sequence and three-dimensional half-fourier acquisition single-shot fast spin echo sequence were performed to measure the signal intensity of these contrast agents respectively, so Gd-DTPA solution with the optimal concentration can be decided as oral negative gastrointestinal contrast agent on MRCP. Clinical study: The Gd-DTPA solution with optimal concentration and volume was regarded as an oral negative gastrointestinal contrast agent of MRCP. Twenty- four' patients were performed with MRCP before and after (5-10 minutes and 10-15 minutes) administration of oral negative gastrointestinal contrast agent and image quality was analyzed. Statistical analysis was performed using analysis of variance with SPSS 10.0. Results: When the concentration of Gd-DTPA solution was ≤0.01 mol/L, the contrast agent was hyperintense on T 1 WI. On T 2 WI, when the concentration was ≥0.015 mol/L, it was as hypointense as basic ground; On 2D FSE MRCP images, controls were hyperintense and the contrast agent with concentration ranging from 0.0025 mol/L to 0.03 mol/L was hypointense. On 3D HEAST MRCP image, controls were hyperintense and when the concentration of Gd-DTPA was ≥0.01 mol, the contrast agent was hypointense. The Gd-DTPA solution with the concentration of 0.01 mol/L and the volume of 100 ml was chosen as MRCP oral negative gastrointestinal contrast agent. On MRCP images after oral administration of the contrast agent, in 10-15 minutes, the average grade scores within 24 patients of the intrahepatic bile duct, the common hepatic bile duct, the gall bladder, the common bile duct and pancreatic duct (the average grade

  8. Development of microbubble contrast agents for high frequency ultrasound microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Se Jung; Kim, Eun A; Park, Sung Hoon; Lee, Hye Jin; Jun, Hong Young; Byun, Seung Jae; Yoon, Kwon Ha [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2007-05-15

    To develop optimal microbubble contrast agents (MBCAs) for performing ultrasound microscopy when examining small animals. We prepared three types of MBCAs. First, a mixture of three parts of 40% dextran and one part of 5% human serum albumin were sonicated with perfluorocarbon (PFC) (MB{sub 1}-D40A5P). Second, three parts of 40% dextran and one part of 1% human serum albumin were sonicated with PFC (MB{sub 2}-D40A1P). Third, all parts of 1% bovine serum albumin were sonicated with PFC (MB{sub 3}-A1P). We measured the microbubbles' sizes and concentrations with using image analysis software. The acoustic properties of the microbubbles were assessed both in vitro and in vivo. The majority of the MB{sub 1}-D40A5Ps had a diameter of 2-5 {mu} m, the mean diameter of the MB{sub 2}-D40A1Ps was 2.5 {mu} m, and the mean diameter of the MB{sub 3}-A1Ps was less than 2.0 {mu} m. Among the microbubbles, the MB{sub 1}-D40A5Ps and MB{sub 2}-D40A1Ps showed increased echogenicity in the abdominal vessels, but the duration of their contrast effect was less than 30 sec. On the contrary, the MB3-A1Ps exhibited strong enhancement in the vessels and their duration was greater than 120 sec. A microbubble contrast agent consisting of all parts of 1% serum albumin sonicated with PFC is an effective contrast agent for ultrasound microscopy.

  9. Self-Assembled Nanomicelles as MRI Blood-Pool Contrast Agent.

    Science.gov (United States)

    Babič, Andrej; Vorobiev, Vassily; Xayaphoummine, Céline; Lapicorey, Gaëlle; Chauvin, Anne-Sophie; Helm, Lothar; Allémann, Eric

    2018-01-26

    Gadolinium-loaded nanomicelles show promise as future magnetic resonance imaging (MRI) contrast agents (CAs). Their increased size and high gadolinium (Gd) loading gives them an edge in proton relaxivity over smaller molecular Gd-complexes. Their size and stealth properties are fundamental for their long blood residence time, opening the possibility for use as blood-pool contrast agents. Using l-tyrosine as a three-functional scaffold we synthesized a nanostructure building block 8. The double C18 aliphatic chain on one side, Gd-1,4,7,10-tetraazacyclododecane-1-4-7-triacetic acid (Gd-DO3A) with access to bulk water in the center and 2 kDa PEG on the hydrophilic side gave the amphiphilic properties required for the core-shell nanomicellar architecture. The self-assembly into Gd-loaded monodispersed 10-20 nm nanomicelles occurred spontaneously in water. These nanomicelles (Tyr-MRI) display very high relaxivity at 29 mm -1  s -1 at low field strength and low cytotoxicity. Good contrast enhancement of the blood vessels and the heart together with prolonged circulation time in vivo, makes Tyr-MRI an excellent candidate for a new supramolecular blood-pool MRI CA. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Hafnium-Based Contrast Agents for X-ray Computed Tomography.

    Science.gov (United States)

    Berger, Markus; Bauser, Marcus; Frenzel, Thomas; Hilger, Christoph Stephan; Jost, Gregor; Lauria, Silvia; Morgenstern, Bernd; Neis, Christian; Pietsch, Hubertus; Sülzle, Detlev; Hegetschweiler, Kaspar

    2017-05-15

    Heavy-metal-based contrast agents (CAs) offer enhanced X-ray absorption for X-ray computed tomography (CT) compared to the currently used iodinated CAs. We report the discovery of new lanthanide and hafnium azainositol complexes and their optimization with respect to high water solubility and stability. Our efforts culminated in the synthesis of BAY-576, an uncharged hafnium complex with 3:2 stoichiometry and broken complex symmetry. The superior properties of this asymmetrically substituted hafnium CA were demonstrated by a CT angiography study in rabbits that revealed excellent signal contrast enhancement.

  11. A theranostic dental pulp capping agent with improved MRI and CT contrast and biological properties.

    Science.gov (United States)

    Mastrogiacomo, S; Güvener, N; Dou, W; Alghamdi, H S; Camargo, W A; Cremers, J G O; Borm, P J A; Heerschap, A; Oosterwijk, E; Jansen, J A; Walboomers, X F

    2017-10-15

    Different materials have been used for vital dental pulp treatment. Preferably a pulp capping agent should show appropriate biological performance, excellent handling properties, and a good imaging contrast. These features can be delivered into a single material through the combination of therapeutic and diagnostic agents (i.e. theranostic). Calcium phosphate based composites (CPCs) are potentially ideal candidate for pulp treatment, although poor imaging contrast and poor dentino-inductive properties are limiting their clinical use. In this study, a theranostic dental pulp capping agent was developed. First, imaging properties of the CPC were improved by using a core-shell structured dual contrast agent (csDCA) consisting of superparamagnetic iron oxide (SPIO) and colloidal gold, as MRI and CT contrast agent respectively. Second, biological properties were implemented by using a dentinogenic factor (i.e. bone morphogenetic protein 2, BMP-2). The obtained CPC/csDCA/BMP-2 composite was tested in vivo, as direct pulp capping agent, in a male Habsi goat incisor model. Our outcomes showed no relevant alteration of the handling and mechanical properties (e.g. setting time, injectability, and compressive strength) by the incorporation of csDCA particles. In vivo results proved MRI contrast enhancement up to 7weeks. Incisors treated with BMP-2 showed improved tertiary dentin deposition as well as faster cement degradation as measured by µCT assessment. In conclusion, the presented theranostic agent matches the imaging and regenerative requirements for pulp capping applications. In this study, we combined diagnostic and therapeutic agents in order to developed a theranostic pulp capping agent with enhanced MRI and CT contrast and improved dentin regeneration ability. In our study we cover all the steps from material preparation, mechanical and in vitro characterization, to in vivo study in a goat dental model. To the best of our knowledge, this is the first time that a

  12. High-Relaxivity MRI Contrast Agents: Where Coordination Chemistry Meets Medical Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Werner, Eric J.; Datta, Ankona; Jocher, Christoph J.; Raymond, Kenneth N.

    2008-01-15

    The desire to improve and expand the scope of clinical magnetic resonance imaging (MRI) has prompted the search for contrast agents of higher efficiency. The development of better agents requires consideration of the fundamental coordination chemistry of the gadolinium(III) ion and the parameters that affect its efficacy as a proton relaxation agent. In optimizing each parameter, other practical issues such as solubility and in vivo toxicity must also be addressed, making the attainment of safe, high-relaxivity agents a challenging goal. Here we present recent advances in the field, with an emphasis on the hydroxypyridinone family of Gd{sup III} chelates.

  13. Arterial double-contrast dual-energy MDCT: in-vivo rabbit atherosclerosis with iodinated nanoparticles and gadolinium agents

    Science.gov (United States)

    Carmi, Raz; Kafri, Galit; Altman, Ami; Goshen, Liran; Planer, David; Sosna, Jacob

    2010-03-01

    An in-vivo feasibility study of potentially improved atherosclerosis CT imaging is presented. By administration of two different contrast agents to rabbits with induced atherosclerotic plaques we aim at identifying both soft plaque and vessel lumen simultaneously. Initial injection of iodinated nanoparticle (INP) contrast agent (N1177 - Nanoscan Imaging), two to four hours before scan, leads to its later accumulation in macrophage-rich soft plaque, while a second gadolinium contrast agent (Magnevist) injected immediately prior to the scan blends with the aortic blood. The distinction between the two agents in a single scan is achieved with a double-layer dual-energy MDCT (Philips Healthcare) following material separation analysis using the reconstructed images of the different x-ray spectra. A single contrast agent injection scan, where only INP was injected two hours prior to the scan, was compared to a double-contrast scan taken four hours after INP injection and immediately after gadolinium injection. On the single contrast agent scan we observed along the aorta walls, localized iodine accumulation which can point on INP uptake by atherosclerotic plaque. In the double-contrast scan the gadolinium contributes a clearer depiction of the vessel lumen in addition to the lasting INP presence. The material separation shows a good correlation to the pathologies inferred from the conventional CT images of the two different scans while performing only a single scan prevents miss-registration problems and reduces radiation dose. These results suggest that a double-contrast dual-energy CT may be used for advanced clinical diagnostic applications.

  14. Tumor Vessel Compression Hinders Perfusion of Ultrasonographic Contrast Agents1

    Science.gov (United States)

    Galiè, Mirco; D'Onofrio, Mirko; Montani, Maura; Amici, Augusto; Calderan, Laura; Marzola, Pasquina; Benati, Donatella; Merigo, Flavia; Marchini, Cristina; Sbarbati, Andrea

    2005-01-01

    Abstract Contrast-enhanced ultrasound (CEUS) is an advanced approach to in vivo assessment of tumor vascularity and is being increasingly adopted in clinical oncology. It is based on 1- to 10 µm-sized gas microbubbles, which can cross the capillary beds of the lungs and are effective echo enhancers. It is known that high cell density, high transendothelial fluid exchange, and poorly functioning lymphatic circulation all provoke solid stress, which compresses vessels and drastically reduces tumor blood flow. Given their size, we supposed that the perfusion of microbubbles is affected by anatomic features of tumor vessels more than are contrast agents traditionally used in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Here, we compared dynamic information obtained from CEUS and DCE-MRI on two experimental tumor models exhibiting notable differences in vessel anatomy. We found that tumors with small, flattened vessels show a much higher resistance to microbubble perfusion than to MRI contrast agents, and appear scarcely vascularized at CEUS examination, despite vessel volume adequate for normal function. Thus, whereas CEUS alone could induce incorrect diagnosis when tumors have small or collapsed vessels, integrated analysis using CEUS and DCE-MRI allows in vivo identification of tumors with a vascular profile frequently associated with malignant phenotypes. PMID:15967105

  15. Ultrasound contrast agents: An overview

    International Nuclear Information System (INIS)

    Cosgrove, David

    2006-01-01

    With the introduction of microbubble contrast agents, diagnostic ultrasound has entered a new era that allows the dynamic detection of tissue flow of both the macro and microvasculature. Underpinning this development is the fact that gases are compressible, and thus the microbubbles expand and contract in the alternating pressure waves of the ultrasound beam, while tissue is almost incompressible. Special software using multiple pulse sequences separates these signals from those of tissue and displays them as an overlay or on a split screen. This can be done at low acoustic pressures (MI < 0.3) so that the microbubbles are not destroyed and scanning can continue in real time. The clinical roles of contrast enhanced ultrasound scanning are expanding rapidly. They are established in echocardiography to improve endocardial border detection and are being developed for myocardial perfusion. In radiology, the most important application is the liver, especially for focal disease. The approach parallels that of dynamic CT or MRI but ultrasound has the advantages of high spatial and temporal resolution. Thus, small lesions that can be indeterminate on CT can often be studied with ultrasound, and situations where the flow is very rapid (e.g., focal nodular hyperplasia where the first few seconds of arterial perfusion may be critical to making the diagnosis) are readily studied. Microbubbles linger in the extensive sinusoidal space of normal liver for several minutes whereas they wash out rapidly from metastases, which have a low vascular volume and thus appear as filling defects. The method has been shown to be as sensitive as three-phase CT. Microbubbles have clinical uses in many other applications where knowledge of the microcirculation is important (the macrocirculation can usually be assessed adequately using conventional Doppler though there are a few important situations where the signal boost given by microbubbles is useful, e.g., transcranial Doppler for evaluating

  16. Biochemical Stability Analysis of Nano Scaled Contrast Agents Used in Biomolecular Imaging Detection of Tumor Cells

    Science.gov (United States)

    Kim, Jennifer; Kyung, Richard

    Imaging contrast agents are materials used to improve the visibility of internal body structures in the imaging process. Many agents that are used for contrast enhancement are now studied empirically and computationally by researchers. Among various imaging techniques, magnetic resonance imaging (MRI) has become a major diagnostic tool in many clinical specialties due to its non-invasive characteristic and its safeness in regards to ionizing radiation exposure. Recently, researchers have prepared aqueous fullerene nanoparticles using electrochemical methods. In this paper, computational simulations of thermodynamic stabilities of nano scaled contrast agents that can be used in biomolecular imaging detection of tumor cells are presented using nanomaterials such as fluorescent functionalized fullerenes. In addition, the stability and safety of different types of contrast agents composed of metal oxide a, b, and c are tested in the imaging process. Through analysis of the computational simulations, the stabilities of the contrast agents, determined by optimized energies of the conformations, are presented. The resulting numerical data are compared. In addition, Density Functional Theory (DFT) is used in order to model the electron properties of the compound.

  17. Contrasting effects of cord injury on intravenous and oral pharmacokinetics of diclofenac: a drug with intermediate hepatic extraction.

    Science.gov (United States)

    Cruz-Antonio, L; Arauz, J; Franco-Bourland, R E; Guízar-Sahagún, G; Castañeda-Hernández, G

    2012-08-01

    Laboratory investigation in rats submitted to experimental spinal cord injury (SCI). To determine the effect of acute SCI on the pharmacokinetics of diclofenac, a marker drug of intermediate hepatic extraction, administered by the intravenous and the oral routes. Female Wistar rats were submitted to complete section of the spinal cord at the T8 level. SCI and sham-injured rats received 3.2 mg kg(-1) of diclofenac sodium either intravenously or orally, diclofenac concentration was measured in whole blood samples and pharmacokinetic parameters were estimated. Diclofenac was not selected as test drug because of its therapeutic properties, but because to its biopharmaceutical properties, that is, intermediate hepatic extraction. Diclofenac bioavailability after intravenous administration was increased in injured rats compared with controls due to a reduced clearance. In contrast, oral diclofenac bioavailability was diminished in SCI animals due to a reduction in drug absorption, which overrides the effect on clearance. Acute SCI induces significant pharmacokinetic changes for diclofenac, a marker drug with intermediate hepatic extraction. SCI-induced pharmacokinetic changes are not only determined by injury characteristics, but also by the route of administration and the biopharmaceutical properties of the studied drug.

  18. Superparamagnetic Bifunctional Bisphosphonates Nanoparticles: A Potential MRI Contrast Agent for Osteoporosis Therapy and Diagnostic

    Directory of Open Access Journals (Sweden)

    Y. Lalatonne

    2010-01-01

    Full Text Available A bone targeting nanosystem is reported here which combined magnetic contrast agent for Magnetic Resonance Imaging (MRI and a therapeutic agent (bisphosphonates into one drug delivery system. This new targeting nanoplatform consists of superparamagnetic γFe2O3 nanoparticles conjugated to 1,5-dihydroxy-1,5,5-tris-phosphono-pentyl-phosphonic acid (di-HMBPs molecules with a bisphosphonate function at the outer of the nanoparticle surface for bone targeting. The as-synthesized nanoparticles were evaluated as a specific MRI contrast agent by adsorption study onto hydroxyapatite and MRI measurment. The strong adsorption of the bisphosphonates nanoparticles to hydroxyapatite and their use as MRI T2∗ contrast agent were demonstrated. Cellular tests performed on human osteosarcoma cells (MG63 show that γFe2O3@di-HMBP hybrid nanomaterial has no citoxity effect in cell viability and may act as a diagnostic and therapeutic system.

  19. Tissue-specific MR contrast agents. Impact on imaging diagnosis and future prospects

    International Nuclear Information System (INIS)

    Yoshimitsu, Kengo; Nakayama, Tomohiro; Kakihara, Daisuke; Irie, Hiroyuki; Tajima, Tsuyoshi; Asayama, Yoshiki; Hirakawa, Masakazu; Ishigami, Kousei; Honda, Hiroshi

    2005-01-01

    Superparamagnetic iron oxide (SPIO) is the only tissue-specific MR agent currently available in Japan. It is quickly taken up by Kupffer cells at the first pass (either arterial or portal) and becomes clustered in the lysosome, providing characteristic T2 * and T2 shortening effects that suppresses the signal of normal or non-tumorous liver tissue. SPIO has dramatically changed the diagnostic algorithm of liver metastasis in clinical practice, now serving as the gold standard instead of CT during arterial portography (CTAP). Its role in the diagnosis of hepatocellular carcinoma (HCC), however, is somewhat complicated, owing to its heterogeneous uptake by the background cirrhotic liver, as well as by some of the HCCs themselves. It has been shown to be useful in the diagnosis of pseudolesions (arterioportal shunts) and some benign hepatocellular lesions (focal nodular hyperplasia or adenoma) by their complete or partial uptake of SPIO, in contrast to an absence of uptake by true liver lesions. It has also been suggested that the histological grade of HCC affects the degree of SPIO uptake. Thus, SPIO serves as a complementary tool to the primary modalities of vascular survey, namely, dynamic CT/MR and CT during hepatic arteriography (CTHA)/CTAP, in the diagnosis of HCC. Gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) is a novel hepatobiliary contrast agent that is not yet available but is supposed to be approved by the Ministry of Health, Labour, and Welfare of Japan in the near future. It is taken up by hepatocytes and excreted into the bile, providing a T1-shortening effect that enhances the normal or non-tumorous liver tissue. It has also been shown to have the effect of positive enhancement of hypervascular liver tumors on the arterial phase, just like the usual extracellular contrast agent (gadopentetate dimeglumine: Gd-DTPA). Thus, Gd-EOB-DTPA was once thought to be an ideal contrast agent for liver tumors, providing information on both

  20. A naturally occurring contrast agent for OCT imaging of smokers' lung

    International Nuclear Information System (INIS)

    Yang Ying; Bagnaninchi, Pierre O; Whiteman, Suzanne C; Pittius, Daniel Gey van; Haj, Alicia J El; Spiteri, Monica A; Wang, Ruikang K

    2005-01-01

    Optical coherence tomography (OCT) offers great potential for clinical applications in terms of its cost, safety and real-time imaging capability. Improvement of its resolution for revealing sub-layers or sub-cellular components within a tissue will further widen its application. In this study we report that carbon pigment, which is frequently present in the lungs of smokers, could be used as a contrast agent to improve the OCT imaging of lung tissue. Carbon produced an intense bright OCT image at a relatively deep location. The parallel histopathological section analysis confirmed the presence of carbon pigment in such tissues. The underlying mechanism of the OCT image formation has been discussed based on a model system in which carbon particles were dispersed in agar gel. Calculations and in-depth intensity profiles of OCT revealed that higher refractive index particles with a size close to or smaller than the wavelength would greatly increase backscattering and generate a sharp contrast, while a particle size several times larger than the wavelength would absorb or obstruct the light path. The naturally occurring contrast agent could provide a diagnostic biomarker of lung tissue in smokers. Furthermore, carbon under such circumstances, can be used as an effective exogenous contrast agent, with which specific components or tissues exhibiting early tumour formation can be optically labelled to delineate the location and boundary, providing potential for early cancer detection and its treatment

  1. In vivo X-Ray Computed Tomographic Imaging of Soft Tissue with Native, Intravenous, or Oral Contrast

    Directory of Open Access Journals (Sweden)

    W. Matthew Leevy

    2013-05-01

    Full Text Available X-ray Computed Tomography (CT is one of the most commonly utilized anatomical imaging modalities for both research and clinical purposes. CT combines high-resolution, three-dimensional data with relatively fast acquisition to provide a solid platform for non-invasive human or specimen imaging. The primary limitation of CT is its inability to distinguish many soft tissues based on native contrast. While bone has high contrast within a CT image due to its material density from calcium phosphate, soft tissue is less dense and many are homogenous in density. This presents a challenge in distinguishing one type of soft tissue from another. A couple exceptions include the lungs as well as fat, both of which have unique densities owing to the presence of air or bulk hydrocarbons, respectively. In order to facilitate X-ray CT imaging of other structures, a range of contrast agents have been developed to selectively identify and visualize the anatomical properties of individual tissues. Most agents incorporate atoms like iodine, gold, or barium because of their ability to absorb X-rays, and thus impart contrast to a given organ system. Here we review the strategies available to visualize lung, fat, brain, kidney, liver, spleen, vasculature, gastrointestinal tract, and liver tissues of living mice using either innate contrast, or commercial injectable or ingestible agents with selective perfusion. Further, we demonstrate how each of these approaches will facilitate the non-invasive, longitudinal, in vivo imaging of pre-clinical disease models at each anatomical site.

  2. In vivo X-Ray Computed Tomographic Imaging of Soft Tissue with Native, Intravenous, or Oral Contrast

    Science.gov (United States)

    Wathen, Connor A.; Foje, Nathan; van Avermaete, Tony; Miramontes, Bernadette; Chapaman, Sarah E.; Sasser, Todd A.; Kannan, Raghuraman; Gerstler, Steven; Leevy, W. Matthew

    2013-01-01

    X-ray Computed Tomography (CT) is one of the most commonly utilized anatomical imaging modalities for both research and clinical purposes. CT combines high-resolution, three-dimensional data with relatively fast acquisition to provide a solid platform for non-invasive human or specimen imaging. The primary limitation of CT is its inability to distinguish many soft tissues based on native contrast. While bone has high contrast within a CT image due to its material density from calcium phosphate, soft tissue is less dense and many are homogenous in density. This presents a challenge in distinguishing one type of soft tissue from another. A couple exceptions include the lungs as well as fat, both of which have unique densities owing to the presence of air or bulk hydrocarbons, respectively. In order to facilitate X-ray CT imaging of other structures, a range of contrast agents have been developed to selectively identify and visualize the anatomical properties of individual tissues. Most agents incorporate atoms like iodine, gold, or barium because of their ability to absorb X-rays, and thus impart contrast to a given organ system. Here we review the strategies available to visualize lung, fat, brain, kidney, liver, spleen, vasculature, gastrointestinal tract, and liver tissues of living mice using either innate contrast, or commercial injectable or ingestible agents with selective perfusion. Further, we demonstrate how each of these approaches will facilitate the non-invasive, longitudinal, in vivo imaging of pre-clinical disease models at each anatomical site. PMID:23711461

  3. Ultrasound contrast agents: an overview.

    Science.gov (United States)

    Cosgrove, David

    2006-12-01

    With the introduction of microbubble contrast agents, diagnostic ultrasound has entered a new era that allows the dynamic detection of tissue flow of both the macro and microvasculature. Underpinning this development is the fact that gases are compressible, and thus the microbubbles expand and contract in the alternating pressure waves of the ultrasound beam, while tissue is almost incompressible. Special software using multiple pulse sequences separates these signals from those of tissue and displays them as an overlay or on a split screen. This can be done at low acoustic pressures (MIdeveloped for myocardial perfusion. In radiology, the most important application is the liver, especially for focal disease. The approach parallels that of dynamic CT or MRI but ultrasound has the advantages of high spatial and temporal resolution. Thus, small lesions that can be indeterminate on CT can often be studied with ultrasound, and situations where the flow is very rapid (e.g., focal nodular hyperplasia where the first few seconds of arterial perfusion may be critical to making the diagnosis) are readily studied. Microbubbles linger in the extensive sinusoidal space of normal liver for several minutes whereas they wash out rapidly from metastases, which have a low vascular volume and thus appear as filling defects. The method has been shown to be as sensitive as three-phase CT. Microbubbles have clinical uses in many other applications where knowledge of the microcirculation is important (the macrocirculation can usually be assessed adequately using conventional Doppler though there are a few important situations where the signal boost given by microbubbles is useful, e.g., transcranial Doppler for evaluating vasospasm after subarachnoid haemorrhage). An important situation where demonstrating tissue devitalisation is important is in interstitial ablation of focal liver lesions: using microbubble contrast agents at the end of a procedure allows immediate evaluation of the

  4. Magnetic iron oxide for contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Fahlvik, A.K.

    1991-05-01

    The main objective of this experimental work has been to study the biological fate and the contrast enhancing potential of a model preparation of magnetic iron oxide (MSM) after intravenous injection to rodents. This was achieved by: Studying in vitro contrast efficacy of various magnetic iron oxide preparations by relaxation analysis. Studying in vivo contrast efficacy of MSM by relaxation analysis and NMR imaging. Studying the biodistribution and bioelimination of MSM in independent experiments using relaxation analysis, radioactivity studies and histological techniques. Studying interactions of MSM with target cells and target organelles using ex vivo techniques. Based on the presented experimental study, the MSM model preparation of magnetic iron oxide seems to fulfill basic requirements of NMR contrast agents: efficient proton relaxation, specific in vivo distribution, and biological tolerance. 177 refs., 5 figs., 2 tabs

  5. Influence of contrast agent dose and ultrasound exposure on cardiomyocyte injury induced by myocardial contrast echocardiography in rats.

    Science.gov (United States)

    Miller, Douglas L; Li, Peng; Dou, Chunyan; Gordon, David; Edwards, Chris A; Armstrong, William F

    2005-10-01

    To detect specific cardiomyocyte injury induced by myocardial contrast material-enhanced echocardiography (ie, myocardial contrast echocardiography) in rats and to ascertain the influences of contrast material dose and ultrasound exposure on this injury. All animal procedures were approved by the university committee for the use and care of animals. Myocardial contrast echocardiography with 1:4 electrocardiographic (ECG) triggering was performed at 1.5 MHz in 61 anesthetized rats. Evans blue (EB) dye was injected as the vital stain for cardiomyocyte injury. At the start of myocardial contrast echocardiography, which lasted 10 minutes, perflutren lipid microsphere-based contrast material was infused through the tail vein for 5 minutes. Premature heartbeats were counted from the ECG record. The numbers of EB-stained cells counted on sections of heart specimens obtained 24 hours after myocardial contrast echocardiography and then either fresh frozen or embedded in paraffin were determined by using fluorescence microscopy. Results were compared statistically by using t tests and Mann-Whitney rank sum tests. EB-stained cells were concentrated in the anterior region of the myocardium. In the paraffin-embedded specimens, EB-stained cells were often accompanied by but largely separate from areas of inflammatory cell infiltration. At end-systolic triggering with a 50 microL/kg dose of microsphere contrast material, the EB-stained cell count increased with increasing peak rarefactional pressure amplitude, with significantly increased cell counts at 1.6 MPa (P .1). EB-stained cell counts increased with increasing contrast material dose, from 10 to 50 microL/kg, at 2.0 MPa. Cardiomyocyte injury was induced by the interaction of ultrasound pulses with contrast agent microbubbles during myocardial contrast echocardiography in rats, and the numbers of injured cells increased with increasing contrast agent dose and ultrasound exposure. RSNA, 2005

  6. Thermal dependence of ultrasound contrast agents scattering efficiency for echographic imaging techniques

    Science.gov (United States)

    Biagioni, Angelo; Bettucci, Andrea; Passeri, Daniele; Alippi, Adriano

    2015-06-01

    Ultrasound contrast agents are used in echographic imaging techniques to enhance image contrast. In addition, they may represent an interesting solution to the problem of non-invasive temperature monitoring inside the human body, based on some thermal variations of their physical properties. Contrast agents, indeed, are inserted into blood circulation and they reach the most important organs inside the human body; consequently, any thermometric property that they may possess, could be exploited for realizing a non-invasive thermometer. They essentially are a suspension of microbubbles containing a gas enclosed in a phospholipid membrane; temperature variations induce structural modifications of the microbubble phospholipid shell, thus causing thermal dependence of contrast agent's elastic characteristics. In this paper, the acoustic scattering efficiency of a bulk suspension of of SonoVue® (Bracco SpA Milan, Italy) has been studied using a pulse-echo technique in the frequency range 1-17 MHz, as it depends upon temperatures between 25 and 65°C. Experimental data confirm that the ultrasonic attenuation coefficient of SonoVue® depends on temperature between 25 and 60°C. Chemical composition of the bubble shell seem to support the hypothesis that a phase transition in the microstructure of lipid-coated microbubbles could play a key role in explaining such effect.

  7. Effect of corticosteroids on phlebitis induced by intravenous infusion of antineoplastic agents in rabbits.

    Science.gov (United States)

    Kohno, Emiko; Murase, Saori; Matsuyama, Kenji; Okamura, Noboru

    2009-08-06

    Phlebitis caused by intravenous infusion of antineoplastic agents is one of the critical problems when anticancer therapy is prolonged. We have already reported that both rapid infusion and dilution of the injection solution were effective methods for reducing phlebitis caused by vinorelbine (VNR) in rabbits. The aim of this study was to explore other practical methods for preventing phlebitis caused by VNR and doxorubicin (DXR) in a rabbit model. VNR is often used with cisplatin, and dexamethasone (DEX) has been co-administered for prevention of cisplatin-induced nausea. DXR is used with prednisolone (PSL) in the CHOP regimen for the treatment of non-Hodgkin's lymphoma. Therefore, the present study investigated the prevention of phlebitis due to VNR with DEX and that due to DXR with PSL. VNR and DXR were diluted with normal saline to prepare test solutions at concentrations of 0.6 mg/mL and 1.4 mg/mL, respectively. Each test solution was infused into the auricular veins of rabbits. Two days after VNR infusion and three days after DXR infusion, the veins were evaluated histopathologically. The effect of DEX on VNR-induced phlebitis was evaluated by infusion of DEX before or after VNR. The effect of PSL on DXR-induced phlebitis was similarly evaluated by co-infusion of PSL. The histopathological features of phlebitis caused by the antineoplastic agents differed between VNR and DXR: VNR did not cause the loss of venous endothelial cells, but caused inflammatory cell infiltration, edema, and epidermal degeneration. In contrast, DXR caused the loss of venous endothelial cells and chrondrocyte necrosis. Pre-treatment and post-treatment with DEX significantly decreased VNR-induced phlebitis compared with the control group and pre-treatment was particularly effective. Co-infusion of PSL also significantly decreased phlebitis caused by DXR, but its effect was less marked. The present findings suggested that pre-treatment with DEX may be a useful method for preventing

  8. An albumin-based gold nanocomposites as potential dual mode CT/MRI contrast agent

    Science.gov (United States)

    Zhao, Wenjing; Chen, Lina; Wang, Zhiming; Huang, Yuankui; Jia, Nengqin

    2018-02-01

    In pursuit of the biological detection applications, recent years have witnessed the prosperity of novel multi-modal nanoprobes. In this study, biocompatible bovine serum albumin (BSA)-coated gold nanoparticles (Au NPs) containing Gd (III) as the contrast agent for both X-ray CT and T1-weighted MR imaging is reported. Firstly, the Au NPs with BSA coating (Au@BSA) was prepared through a moderate one-pot reduction route in the presence of hydrazine hydrate as reducer. Sequentially, the BSA coating enables modification of diethylenetriaminepentaacetic acid (DTPA) as well as targeting reagent hyaluronic acid (HA), and further chelation of Gd (III) ions led to the formation of biomimetic nanoagent HA-targeted Gd-Au NPs (HA-targeted Au@BSA-Gd-DTPA). Several techniques were used to thoroughly characterize the formed HA-targeted Gd-Au NPs. As expected, the as-prepared nanoagent with mean diameter of 13.82 nm exhibits not only good colloid stablility and water dispersibility, but also satisfying low cytotoxicity and hemocompatibility in the tested concentration range. Additionally, for the CT phantoms, the obtained nanocomplex shows an improved contrast in CT scanning than that of Au@BSA as well as small molecule iodine-based CT contrast agents such as iopromide. Meanwhile, for the T1-weighted MRI images, there is a linear increase of contrast with concentration of Gd for the two cases of HA-targeted Gd-Au NPs and Magnevist. Strikingly, the nanoagent we explored displays a relatively higher r1 relaxivity than that of commercial MR contrast agents. Therefore, this newly constructed nanoagent could be used as contrast agents for synergistically enhanced X-ray CT and MR phantoms, holding promising potential for future biomedical applications.

  9. A model for ultrasound contrast agent in a phantom vessel

    KAUST Repository

    Qamar, Adnan; Samtaney, Ravi

    2014-01-01

    A theoretical framework to model the dynamics of Ultrasound Contrast Agent (UCA) inside a phantom vessel is presented. The model is derived from the reduced Navier-Stokes equation and is coupled with the evolving flow field solution inside

  10. Diffusion properties of conventional and calcium-sensitive MRI contrast agents in the rat cerebral cortex.

    Science.gov (United States)

    Hagberg, Gisela E; Mamedov, Ilgar; Power, Anthony; Beyerlein, Michael; Merkle, Hellmut; Kiselev, Valerij G; Dhingra, Kirti; Kubìček, Vojtĕch; Angelovski, Goran; Logothetis, Nikos K

    2014-01-01

    Calcium-sensitive MRI contrast agents can only yield quantitative results if the agent concentration in the tissue is known. The agent concentration could be determined by diffusion modeling, if relevant parameters were available. We have established an MRI-based method capable of determining diffusion properties of conventional and calcium-sensitive agents. Simulations and experiments demonstrate that the method is applicable both for conventional contrast agents with a fixed relaxivity value and for calcium-sensitive contrast agents. The full pharmacokinetic time-course of gadolinium concentration estimates was observed by MRI before, during and after intracerebral administration of the agent, and the effective diffusion coefficient D* was determined by voxel-wise fitting of the solution to the diffusion equation. The method yielded whole brain coverage with a high spatial and temporal sampling. The use of two types of MRI sequences for sampling of the diffusion time courses was investigated: Look-Locker-based quantitative T(1) mapping, and T(1) -weighted MRI. The observation times of the proposed MRI method is long (up to 20 h) and consequently the diffusion distances covered are also long (2-4 mm). Despite this difference, the D* values in vivo were in agreement with previous findings using optical measurement techniques, based on observation times of a few minutes. The effective diffusion coefficient determined for the calcium-sensitive contrast agents may be used to determine local tissue concentrations and to design infusion protocols that maintain the agent concentration at a steady state, thereby enabling quantitative sensing of the local calcium concentration. Copyright © 2014 John Wiley & Sons, Ltd.

  11. Ultrasonic microbubble contrast agents and the transplant kidney

    Energy Technology Data Exchange (ETDEWEB)

    Kay, D.H., E-mail: davidhkay@doctors.org.u [Department of Radiology, Western Infirmary, Glasgow (United Kingdom); Mazonakis, M.; Geddes, C. [Department of Renal Medicine, Western Infirmary, Glasgow (United Kingdom); Baxter, G. [Department of Radiology, Western Infirmary, Glasgow (United Kingdom)

    2009-11-15

    Aim: To evaluate the potential application of microbubble agents in the immediate post-transplant period, by studying contrast uptake and washout, and to correlate these values with clinical indices, and thus, assess the potential prognostic value of this technique. Materials and methods: The study group comprised 20 consecutive renal transplant patients within 7 days of transplantation. Sonovue was administered as an intravenous bolus with continuous imaging of the transplant kidney at low mechanical index (MI) for 1 min post-injection. These data were analysed off-line by two observers, and time intensity curves (TIC) for the upper, mid, and lower poles constructed. Within each pole, a region of interest (5 mm square) was placed over the cortex, medullary pyramid, and interlobar artery, resulting in a total of nine TIC for each patient. TIC parameters included the arrival time (AT), time to peak (TTP), peak intensity (Max), gradient of the slope (M), and the area under curve (AUC). Results: For both observers there was good agreement for all values measured from the cortex and medulla, but poor interobserver correlation for the vascular values. In addition, there was only agreement for these values in the upper and mid-pole of the transplant with poor agreement for the lower pole values. The mid-pole of the transplant kidney was chosen as the point of measurement for subsequent studies. Mid-pole values were correlated with clinical data and outcome over the 3-month post-transplant period. Renal microbubble perfusion correlated with the transplant estimated glomerular filtration rate (eGFR) at 3 months post-transplantation (p = 0.016). Discussion: In conclusion, this is the first study to confirm reproducibility of the Sonovue TIC data in transplant patients and to quantify regional variation and perfusion. The statistically significant estimates of transplant perfusion may be of future benefit to transplant recipients and potentially utilized as a prognostic tool

  12. Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment.

    Science.gov (United States)

    Pjontek, Rastislav; Önenköprülü, Belgin; Scholz, Bernhard; Kyriakou, Yiannis; Schubert, Gerrit A; Nikoubashman, Omid; Othman, Ahmed; Wiesmann, Martin; Brockmann, Marc A

    2016-08-01

    Flat panel detector CT angiography with intravenous contrast agent injection (IV CTA) allows high-resolution imaging of cerebrovascular structures. Artifacts caused by metallic implants like platinum coils or clips lead to degradation of image quality and are a significant problem. To evaluate the influence of a prototype metal artifact reduction (MAR) algorithm on image quality in patients with intracranial metallic implants. Flat panel detector CT after intravenous application of 80 mL contrast agent was performed with an angiography system (Artis zee; Siemens, Forchheim, Germany) using a 20 s rotation protocol (200° rotation angle, 20 s acquisition time, 496 projections). The data before and after MAR of 26 patients with a total of 34 implants (coils, clips, stents) were independently evaluated by two blinded neuroradiologists. MAR improved the assessability of the brain parenchyma and small vessels (diameter metallic implants and at a distance of 6 cm (p<0.001 each, Wilcoxon test). Furthermore, MAR significantly improved the assessability of parent vessel patency and potential aneurysm remnants (p<0.005 each, McNemar test). MAR, however, did not improve assessability of stented vessels. When an intravenous contrast protocol is used, MAR significantly ameliorates the assessability of brain parenchyma, vessels, and treated aneurysms in patients with intracranial coils or clips. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Quantitation of MRI sensitivity to quasi-monodisperse microbubble contrast agents for spatially resolved manometry.

    Science.gov (United States)

    Bencsik, Martin; Al-Rwaili, Amgad; Morris, Robert; Fairhurst, David J; Mundell, Victoria; Cave, Gareth; McKendry, Jonathan; Evans, Stephen

    2013-11-01

    The direct in-vivo measurement of fluid pressure cannot be achieved with MRI unless it is done with the contribution of a contrast agent. No such contrast agents are currently available commercially, whilst those demonstrated previously only produced qualitative results due to their broad size distribution. Our aim is to quantitate then model the MR sensitivity to the presence of quasi-monodisperse microbubble populations. Lipid stabilised microbubble populations with mean radius 1.2 ± 0.8 μm have been produced by mechanical agitation. Contrast agents with increasing volume fraction of bubbles up to 4% were formed and the contribution the bubbles bring to the relaxation rate was quantitated. A periodic pressure change was also continuously applied to the same contrast agent, until MR signal changes were only due to bubble radius change and not due to a change in bubble density. The MR data compared favourably with the prediction of an improved numerical simulation. An excellent MR sensitivity of 23 % bar(-1) has been demonstrated. This work opens up the possibility of generating microbubble preparations tailored to specific applications with optimised MR sensitivity, in particular MRI based in-vivo manometry. Copyright © 2012 Wiley Periodicals, Inc.

  14. Risk Stratification of iodine-induced thyrotoxicosis before contrast agent application

    International Nuclear Information System (INIS)

    Fricke, E.

    2004-01-01

    Today, examinations using iodine containing contrast media are rather frequent. Even though in modern contrast agents the content of free iodine is low, in vivo deiodination results in a non physiologic high iodine load of the thyroid gland. Whilst in normal thyroid tissue iodine metabolism and hormone production are self-regulating in spite of the variable iodine load, those mechanisms are disturbed in autonomous thyroid tissue. Clinical studies displayed low risk of iodine induced thyrotoxicosis after application of contrast agent. Nonetheless the clinician has to assess the risk of thyrotoxicosis for each individual patient and he has to decide how to cope with this risk. Thyroid scintigraphy using Tc-99m-pertechnetate with quantitative measurement of the thyroidal uptake (TcTU) has been shown to be a useful tool in this question, especially when performed under suppression of the non-autonomous tissue (TcTUs). In particular patients with pre-existing suppression of the TSH secretion should be selected for this investigation. Also at risk are elderly persons and those with diffuse or nodular goitres. In spite of the high frequency of contrast agent applications, data on scintigraphy for risk evaluation of thyrotoxicosis and on efficacy of prophylactic medication are scarce. Based on own results and on a review of literature, the risk of thyrotoxicosis seems to be negligible in patients with a TcTUs of less than 1% even in case of preexistent latent hyperthyroidism. If a suppressed TSH level is known and TcTUs is higher than 1%, prophylactic medication should be given. There is evidence for a combination therapy inhibiting both iodine uptake and metabolism, i.e. with perchlorate and thiamazole, being more efficient than monotherapy, particularly in patients with high risk of thyrotoxicosis. (orig.)

  15. Enhancement of 67Ga tumor-to-blood ratios by chelating agent

    International Nuclear Information System (INIS)

    Saji, Hideo; Yokoyama, Akira; Hata, Naotaka; Misaki, Atsushi; Tanaka, Hisashi.

    1980-01-01

    Chelating agent, such as, CaEDTA, CaDTPA, D-penicillamine, DMSA, desferoxamine, NTA, cysteine ethyl ester, BAL, α-MPG, phthalein complexone, were tested as a possible contrast enhancing agent for tumor imaging with 67 Ga-citrate. The intravenous administration of a chelating agent to Ehrlich's tumor bearing mice, one hour after the injection of 67 Ga-citrate, accelerated the blood clearance with only a very slight change of activity in the target, increasing the tumor-to-blood ratio, and consequently achieving a better visualization. Among the tested chelating agents, D-penicillamine showed the highest target-to-nontarget ratio at a shorter time: a good tumor-to-blood ratio, performed after 24 hr with non-treated animals, was achieved in only 1-3 hr with post-treated animals. Thus, D-penicillamine hold a considerable promise as a contrast enhancing agent for future clinical use. (author)

  16. The evidence-based evaluation of the safety of contrast media in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Li Jixia; Huang Baosheng

    2009-01-01

    Contrast-induced nephropathy (CIN) has now been the third most common cause of acquired renal failure. Diabetes mellitus (DM), the type of contrast agent used and the intra-arterial route of administration are three important risk factors inducing CIN. The incidence rate of CIN is very high in patients with DM or renal insufficiency after iodinated contrast was administered. Unfortunately, it has not yet attracted physicians'and radiologists'sufficient attention. This paper aims to make an evidence-based evaluation of the safety and rephrotoxicity of various contrast agents when they are used in patients with DM. Usually, intravenous administration of contrast media will not cause permanent damage to the kidney in highrisk patients. Low-osmolarity contrast media is relatively safe for patients with DM only, while it takes much risk of CIN when low-osmolarity contrast media is used in patients with diabetic nephropathy or in patients of DM accompanied with renal insufficiency, for such patients, the iso-osmolarity contrast media, iodixanol, can be used. (authors)

  17. An MR Contrast Agent for Intra-Prostatic Imaging of Prostatic Cancer

    National Research Council Canada - National Science Library

    Josephson, Lee

    2004-01-01

    The goal of the current research is the development of a magnetic nanoparticle based MR contrast agent that binds the gastrin releasing peptide receptor, a molecular marker associated with neoplasia...

  18. Contrast Agents for Micro-Computed Tomography of Microdamage in Bone

    National Research Council Canada - National Science Library

    Roeder, Ryan K

    2008-01-01

    ...) and contrast agents with higher x-ray attenuation than bone. The ability to detect the presence and to a limited extent the morphology of microdamage in cortical and trabecular bone using micro-CT was demonstrated using a barium sulfate (BaSO4) stain...

  19. Intravenous digital subtraction angiography of the lower limbs combined with field movement (2-field DSA)

    International Nuclear Information System (INIS)

    Fritschy, P.; Terrier, F.

    1988-01-01

    We evaluated a bolus-chase technique designed to reduce the volume of contrast material and to shorten examination time during intravenous digital subtraction angiography (IV-DSA) of the lower limbs. With this technique, after a single injection of contrast material, two contiguous fields can be sequentially imaged (two-field DAS) using a step translated X-ray tube. 67 patients with peripheral vascular disease were studied. All examinations provided diagnostic information, so that in no instance additional intra-arterial injections were required. With the two-field DSA only 3.49 injections were needed in the average for five fields examined in each patient, resulting in a 30% reduction of contrast agent used. (orig.) [de

  20. Imaging efficiency of an X-ray contrast agent-incorporated polymeric microparticle.

    Science.gov (United States)

    Ahn, Sungsook; Jung, Sung Yong; Lee, Jin Pyung; Lee, Sang Joon

    2011-01-01

    Biocompatible polymeric encapsulants have been widely used as a delivery vehicle for a variety of drugs and imaging agents. In this study, X-ray contrast agent (iopamidol) is encapsulated into a polymeric microparticle (polyvinyl alcohol) as a particulate flow tracer in synchrotron X-ray imaging system. The physical properties of the designed microparticles are investigated and correlated with enhancement in the imaging efficiency by experimental observation and theoretical interpretation. The X-ray absorption ability of the designed microparticle is assessed by Beer-Lambert-Bouguer law. Particle size, either in dried state or in solvent, primarily dominates the X-ray absorption ability under the given condition, thus affecting imaging efficiency of the designed X-ray contrast flow tracers. Copyright © 2011 John Wiley & Sons, Ltd.

  1. Evaluation of contrast media for bronchography

    International Nuclear Information System (INIS)

    Thompson, I.M.; Whittlesey, G.C.; Slovis, T.L.; Chang, C.H.; Cullen, M.L.; Philippart, A.I.; Stockmann, P.S.; Adkins, E.S.; Klein, M.D.

    1997-01-01

    Background. Bronchography is occasionally needed for the evaluation and management of some congenital pulmonary anomalies as well as some acquired diseases, usually of the tracheo- bronchial tree. There is currently no effective, approved contrast agent for this imaging tech- nique. Objective. We evaluated five agents (barium sulfate, iohexol, propyliodone oily, propyliodone aqueous, and perflubron) in terms of image quality, histologic changes, and effects on hemodynamics, blood gases, and standard laboratory tests in New Zealand White rabbits. Materials and methods. Animals were anesthetized and intubated. Each contrast agent (0.25 ml/kg) was administered intratracheally. Three animals in each group had intravenous lines placed for blood sampling and blood pressure monitoring and were sacrificed at 1 h. An additional three animals for each agent were sacrificed at 24 h and 1 week after imaging. Blood samples were taken immediately before contrast instillation and at 1 h postbronchography. Fluoroscopic images were recorded on standard VHS video tape and evaluated in blind fashion. Segments of lung tissue and bronchi were obtained for histologic examination. Results. Necrosis and/or inflammatory infiltrates were noted in 78 % of the bronchograms performed with propyliodone aqueous, 67 % with propyliodone oily, 55 % with perflubron, and 33 % with iohexol 120, 240 and 350. No histologic damage was observed with barium. The propyliodones gave the best-quality imaging results and the most histologic changes. Iohexol, in any concentration, gave the least acceptable images and a moderate number of histologic changes. Barium sulfate demonstrated acceptable images with virtually no histologic changes. Conclusion. From the histologic and imaging results, barium is the best available contrast material for bronchography. (orig.). With 6 figs., 4 tabs

  2. Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

    Science.gov (United States)

    Yeh, Benjamin M; FitzGerald, Paul F; Edic, Peter M; Lambert, Jack W; Colborn, Robert E; Marino, Michael E; Evans, Paul M; Roberts, Jeannette C; Wang, Zhen J; Wong, Margaret J; Bonitatibus, Peter J

    2017-04-01

    The introduction of spectral CT imaging in the form of fast clinical dual-energy CT enabled contrast material to be differentiated from other radiodense materials, improved lesion detection in contrast-enhanced scans, and changed the way that existing iodine and barium contrast materials are used in clinical practice. More profoundly, spectral CT can differentiate between individual contrast materials that have different reporter elements such that high-resolution CT imaging of multiple contrast agents can be obtained in a single pass of the CT scanner. These spectral CT capabilities would be even more impactful with the development of contrast materials designed to complement the existing clinical iodine- and barium-based agents. New biocompatible high-atomic number contrast materials with different biodistribution and X-ray attenuation properties than existing agents will expand the diagnostic power of spectral CT imaging without penalties in radiation dose or scan time. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Clinical experience with intravenous radiosensitizers in unresectable sarcomas

    International Nuclear Information System (INIS)

    Kinsella, T.J.; Glatstein, E.

    1987-01-01

    Traditionally, adult bone and soft tissue sarcomas have been considered to be ''radioresistant.'' Because of this philosophy, patients who present with locally advanced, unresectable sarcomas often are treated in a palliative fashion, usually with low-dose radiotherapy. Over the last 6 years, 29 patients with unresectable primary or metastatic sarcomas were treated using a combination of intravenous chemical radiosensitizers and high-dose irradiation. Twenty-two of 29 patients achieved clinical local control, with six patients having a complete clinical response. The time to tumor response is often several months or longer, which is in contrast to other tumor histologies (carcinomas, lymphomas), where tumor response usually occurs over several weeks. Several large tumors have shown only a minimal tumor response, yet were found to be sterilized in posttreatment biopsy or autopsy examination. Of 15 patients with primary sarcomas without metastases, 11 patients (73%) remain free of local tumor progression from 12 to 83 months. Adult high-grade sarcomas can be controlled with high-dose radiotherapy and intravenous radiosensitizers, although the precise role of these agents is unclear

  4. Adverse events caused by MRI contrast agents: Implications for radiographers who inject

    International Nuclear Information System (INIS)

    Marshall, Gill; Kasap, Chris

    2012-01-01

    This article provides a comprehensive literature review regarding side effects both minor and major associated with contrast agent injection. This includes a discussion of nephrogenic systemic fibrosis (NSF), which remains highly topical. Radiographers now commonly are responsible for injection of contrast agent in patients, in keeping with their extended role. Therefore it is incumbent on them to understand the agents they inject, the contra-indications for injection and any potential associated risks, so that they can act and react accordingly in a timely manner. The need for this knowledge was made very evident after the recent death of a patient from anaphylactic shock when there was a delay in mounting the appropriate procedure. This paper represents a synthesis of relevant articles and reflects on the results, before drawing appropriate conclusions particularly those of special relevance to radiographers.

  5. Pre-clinical evaluation of a nanoparticle-based blood-pool contrast agent for MR imaging of the placenta.

    Science.gov (United States)

    Ghaghada, Ketan B; Starosolski, Zbigniew A; Bhayana, Saakshi; Stupin, Igor; Patel, Chandreshkumar V; Bhavane, Rohan C; Gao, Haijun; Bednov, Andrey; Yallampalli, Chandrasekhar; Belfort, Michael; George, Verghese; Annapragada, Ananth V

    2017-09-01

    Non-invasive 3D imaging that enables clear visualization of placental margins is of interest in the accurate diagnosis of placental pathologies. This study investigated if contrast-enhanced MRI performed using a liposomal gadolinium blood-pool contrast agent (liposomal-Gd) enables clear visualization of the placental margins and the placental-myometrial interface (retroplacental space). Non-contrast MRI and contrast-enhanced MRI using a clinically approved conventional contrast agent were used as comparators. Studies were performed in pregnant rats under an approved protocol. MRI was performed at 1T using a permanent magnet small animal scanner. Pre-contrast and post-liposomal-Gd contrast images were acquired using T1-weighted and T2-weighted sequences. Dynamic Contrast enhanced MRI (DCE-MRI) was performed using gadoterate meglumine (Gd-DOTA, Dotarem ® ). Visualization of the retroplacental clear space, a marker of normal placentation, was judged by a trained radiologist. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated for both single and averaged acquisitions. Images were reviewed by a radiologist and scored for the visualization of placental features. Contrast-enhanced CT (CE-CT) imaging using a liposomal CT agent was performed for confirmation of the MR findings. Transplacental transport of liposomal-Gd was evaluated by post-mortem elemental analysis of tissues. Ex-vivo studies in perfused human placentae from normal, GDM, and IUGR pregnancies evaluated the transport of liposomal agent across the human placental barrier. Post-contrast T1w images acquired with liposomal-Gd demonstrated significantly higher SNR (p = 0.0002) in the placenta compared to pre-contrast images (28.0 ± 4.7 vs. 6.9 ± 1.8). No significant differences (p = 0.39) were noted between SNR in pre-contrast and post-contrast liposomal-Gd images of the amniotic fluid, indicating absence of transplacental passage of the agent. The placental margins were

  6. An MR Contrast Agent for Intra-Prostatic Imaging of Prostatic Cancer

    National Research Council Canada - National Science Library

    Josephson, Lee

    2005-01-01

    An MR contrast agent targeted to the GRP receptor will be a novel pharmaceutical capable of non-invasively, and at high spatial resolution, characterizing healthy and patholological regions within the prostate...

  7. Contrast agent based on nano-emulsion for targeted biomedical imaging

    International Nuclear Information System (INIS)

    Attia, Mohamed

    2016-01-01

    X-ray imaging agents are essential in combination with X-ray computed tomography to improve contrast enhancement aiming at providing complete visualization of blood vessels and giving structural and functional information on lesions allowing the detection of a tumor. As well as it is fundamental tool to discriminate between healthy cells and pathogens. We successfully limit the problems presented in commercial X-ray contrast agents like poor contrasting in Fenestra VC associated with short blood circulation time and to avoid rapid renal elimination from the body as found in Xenetix (Iobitriol). We developed nontoxic and blood pool iodine-containing nano-emulsion contrast agents serving in preclinical X-ray μ-CT imaging such as, a- Tocopherol (vitamin E), Cholecalciferol (vitamin D3), Castor oil, Capmul MCMC8 oil and oleic acid. Those formulated nano emulsions were prepared by low energy spontaneous emulsification technic with slight modification for each platform. They showed new specific features rendering them promising agents in in vivo experiments as improving the balance between the efficacy and the toxicity of targeted therapeutic interventions. We investigate the effect of size and the chemical composition of the nanoparticles on their biodistribution, pharmacokinetics and toxicity. They demonstrated that the chemical structures of the droplet's cores have significant role in targeting for example vitamin E was mainly accumulated in liver and castor oil formulation was passively accumulated in spleen explaining the proof-of-concept of EPR effect. On the other hand, two different platform sizes of Cholecalciferol molecule revealing that no real impact on the pharmacokinetics and biodistribution but presented remarkable effect on the toxicity. Of particular interest is studying the effect of the surface charge of nanoparticles on their biodistribution, this is why oleic acid nano-emulsion was selected to proceed this study by presence of amphiphilic polymer

  8. Synthesis of Laboratory Ultrasound Contrast Agents

    Directory of Open Access Journals (Sweden)

    Jaemin Oh

    2013-10-01

    Full Text Available Ultrasound Contrast Agents (UCAs were developed to maximize reflection contrast so that organs can be seen clearly in ultrasound imaging. UCAs increase the signal to noise ratio (SNR by linear and non-linear mechanisms and thus help more accurately visualize the internal organs and blood vessels. However, the UCAs on the market are not only expensive, but are also not optimized for use in various therapeutic research applications such as ultrasound-aided drug delivery. The UCAs fabricated in this study utilize conventional lipid and albumin for shell formation and perfluorobutane as the internal gas. The shape and density of the UCA bubbles were verified by optical microscopy and Cryo SEM, and compared to those of the commercially available UCAs, Definity® and Sonovue®. The size distribution and characteristics of the reflected signal were also analyzed using a particle size analyzer and ultrasound imaging equipment. Our experiments indicate that UCAs composed of spherical microbubbles, the majority of which were smaller than 1 um, were successfully synthesized. Microbubbles 10 um or larger were also identified when different shell characteristics and filters were used. These laboratory UCAs can be used for research in both diagnoses and therapies.

  9. Safety assessment of nanoparamagnetic contrast agents with different coatings for molecular MRI

    Science.gov (United States)

    Azizian, Gholamreza; Riyahi-Alam, Nader; Haghgoo, Soheila; Saffari, Mojtaba; Zohdiaghdam, Reza; Gorji, Ensieh

    2013-04-01

    Despite the wide application of gadolinium as a contrast agent for magnetic resonance imaging (MRI), there is a serious lack of information on its toxicity. Gadolinium and gadolinium oxide (Gd-oxide) are used as contrast agents for magnetic resonance imaging (MRI). There are methods for reducing toxicity of these materials, such as core nanoparticles coating or conjugating. Therefore, for toxicity evaluation, we compared the viability of commercial contrast agents in MRI (Gd-DTPA) and three nanoparticles with the same core Gd2O3 and small particulate gadolinium oxide or SPGO (DTPA. The MTT and LDH assay results showed that Gd2O3-DEG nanoparticles were more toxic than Gd-DTPA and other nanoparticles. Also, SPGO-mPEG-silane2000 was more biocompatible than other nanoparticles. The obtained results did not show any significant increase in cytotoxicity of the nanoparticles and Gd-DTPA, neither dose-dependent nor time-dependent. Therefore, DEG and PEG, due to their considerable properties and irregular sizes (different molecular weights), were selected as the useful surface covering materials of nanomagnetic particles that could reveal noticeable relaxivity and biocompatibility characteristics.

  10. Computed tomography enterography: a comparison of different neutral oral contrast agents

    International Nuclear Information System (INIS)

    D'Ippolito, Giuseppe; Braga, Fernanda Angeli; Resende, Marcelo Cardoso; Bretas, Elisa Almeida Sathler; Nunes, Thiago Franchi; Rosas, George de Queiroz; Tiferes, Dario Arie

    2012-01-01

    Objective: The purpose of this study was to assess the performance of neutral oral contrast agents, comparing intestinal distension, distinction of intestinal wall, acceptance and side effects. Materials and Methods: Prospective, randomized, and double-blinded study involving 30 patients who underwent computed tomography of abdomen and pelvis with administration of neutral oral contrast agents, divided into three groups according the contrast agent type: milk, water, and polyethylene glycol. The images were consensually analyzed by two observers, considering the degree of bowel distension and intestinal wall distinction. The patients responded to a questionnaire regarding the taste of the ingested solution and on their side effects. Kruskal-Wallis and chi-square tests were employed for statistical analysis. Results: Among 40 studied intestinal segments, appropriate bowel distension (intestinal loop diameter > 2 cm) was observed in 14 segments (35%) in the milk group, 10 segments (25%) in the water group and 23 segments (57%) in the polyethylene glycol group (p = 0.01). Preparation with polyethylene glycol resulted in the best bowel distension, but it presented the worst taste and highest incidence of diarrhea as reported by patients. Conclusion: Bowel preparation with oral polyethylene glycol results in higher degree of bowel distension than with water or milk, but presents worst acceptance related to its taste and frequency of diarrhea as a side effect. (author)

  11. Computed tomography enterography: a comparison of different neutral oral contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Department of Imaging Diagnosis, Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); Braga, Fernanda Angeli; Resende, Marcelo Cardoso; Bretas, Elisa Almeida Sathler; Nunes, Thiago Franchi; Rosas, George de Queiroz; Tiferes, Dario Arie [Abdominal Imaging Section, Department of Imaging Diagnosis - Universidade Federal de Sao Paulo (Unifesp), Sao Paulo, SP (Brazil)

    2012-05-15

    Objective: The purpose of this study was to assess the performance of neutral oral contrast agents, comparing intestinal distension, distinction of intestinal wall, acceptance and side effects. Materials and Methods: Prospective, randomized, and double-blinded study involving 30 patients who underwent computed tomography of abdomen and pelvis with administration of neutral oral contrast agents, divided into three groups according the contrast agent type: milk, water, and polyethylene glycol. The images were consensually analyzed by two observers, considering the degree of bowel distension and intestinal wall distinction. The patients responded to a questionnaire regarding the taste of the ingested solution and on their side effects. Kruskal-Wallis and chi-square tests were employed for statistical analysis. Results: Among 40 studied intestinal segments, appropriate bowel distension (intestinal loop diameter > 2 cm) was observed in 14 segments (35%) in the milk group, 10 segments (25%) in the water group and 23 segments (57%) in the polyethylene glycol group (p = 0.01). Preparation with polyethylene glycol resulted in the best bowel distension, but it presented the worst taste and highest incidence of diarrhea as reported by patients. Conclusion: Bowel preparation with oral polyethylene glycol results in higher degree of bowel distension than with water or milk, but presents worst acceptance related to its taste and frequency of diarrhea as a side effect. (author)

  12. Optical-based molecular imaging: contrast agents and potential medical applications

    International Nuclear Information System (INIS)

    Bremer, Christoph; Ntziachristos, Vasilis; Weissleder, Ralph

    2003-01-01

    Laser- and sensitive charge-coupled device technology together with advanced mathematical modelling of photon propagation in tissue has prompted the development of novel optical imaging technologies. Fast surface-weighted imaging modalities, such as fluorescence reflectance imaging (FRI) and 3D quantitative fluorescence-mediated tomography have now become available [1, 2]. These technical advances are paralleled by a rapid development of a whole range of new optical contrasting strategies, which are designed to generate molecular contrast within a living organism. The combination of both, technical advances of light detection and the refinement of optical contrast media, finally yields a new spectrum of tools for in vivo molecular diagnostics. Whereas the technical aspects of optical imaging are covered in more detail in a previous review article in ''European Radiology'' [3], this article focuses on new developments in optical contrasting strategies and design of optical contrast agents for in vivo diagnostics. (orig.)

  13. Viscosity of iodinated contrast agents during renal excretion

    International Nuclear Information System (INIS)

    Jost, Gregor; Lengsfeld, Philipp; Lenhard, Diana C.; Pietsch, Hubertus; Huetter, Joachim; Sieber, Martin A.

    2011-01-01

    Objective: Modern iodinated non-ionic contrast agents (CAs) can be classified based on their molecular structure into monomeric and dimeric CAs and have at comparable iodine concentrations a different viscosity and osmolality. During their renal excretion, CAs are concentrated in the renal tubuli which might enhance the viscosity difference between monomeric and dimeric CAs. The viscosity of a CA might have an underestimated importance for renal safety, as suggested by recent publications. In this study, we investigated the viscosities of CAs at the concentrations expected to be present in renal tubules. This concentration process was simulated in vitro using dialysis. Furthermore, we investigated urine viscosity and urine flow in rodents after administration of several non-ionic monomeric and dimeric CAs. Materials and methods: To estimate the viscosity of the CAs in vivo, we performed an in vitro dialysis of monomeric and dimeric CAs at various physiological osmolalities of the renal tubulus (290, 400, 500, 700 and 1000 mOsm/kg H 2 O). Following the dialysis, the iodine concentrations and the viscosities of the CAs were determined. Furthermore, to investigate the concentration process in vivo, we measured the urine viscosity and the urine flow in Han Wister rats after the administration of Iopromide, Iohexol, Ioversol, Iomeprol, Iodixanol, and Iosimenol at comparable iodine concentrations. As a control, saline was injected at the same volume. Results: In vitro dialysis of the dimeric CA increased the iodine concentration and strongly increased the viscosity at all tested osmolalities. In contrast, for the monomeric agents an increase in concentration and viscosity was observed only at 700 as well 1000 mOsm/kg H 2 O but to a lesser extent. In summary, dialysis strongly enhanced the viscosity differences between the non-ionic monomeric and dimeric CAs. The administration of dimeric CAs leads to a strong increase in urine viscosity; this was not observed for the

  14. Viscosity of iodinated contrast agents during renal excretion

    Energy Technology Data Exchange (ETDEWEB)

    Jost, Gregor, E-mail: Gregor.Jost@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Lengsfeld, Philipp, E-mail: Philipp.Lengsfeld@bayer.com [Global Medical Affairs Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Lenhard, Diana C., E-mail: Diana.Lenhard@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Pietsch, Hubertus, E-mail: Hubertus.Pietsch@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Huetter, Joachim, E-mail: Joachim.Huetter@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Sieber, Martin A., E-mail: Martin.Sieber@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany)

    2011-11-15

    Objective: Modern iodinated non-ionic contrast agents (CAs) can be classified based on their molecular structure into monomeric and dimeric CAs and have at comparable iodine concentrations a different viscosity and osmolality. During their renal excretion, CAs are concentrated in the renal tubuli which might enhance the viscosity difference between monomeric and dimeric CAs. The viscosity of a CA might have an underestimated importance for renal safety, as suggested by recent publications. In this study, we investigated the viscosities of CAs at the concentrations expected to be present in renal tubules. This concentration process was simulated in vitro using dialysis. Furthermore, we investigated urine viscosity and urine flow in rodents after administration of several non-ionic monomeric and dimeric CAs. Materials and methods: To estimate the viscosity of the CAs in vivo, we performed an in vitro dialysis of monomeric and dimeric CAs at various physiological osmolalities of the renal tubulus (290, 400, 500, 700 and 1000 mOsm/kg H{sub 2}O). Following the dialysis, the iodine concentrations and the viscosities of the CAs were determined. Furthermore, to investigate the concentration process in vivo, we measured the urine viscosity and the urine flow in Han Wister rats after the administration of Iopromide, Iohexol, Ioversol, Iomeprol, Iodixanol, and Iosimenol at comparable iodine concentrations. As a control, saline was injected at the same volume. Results: In vitro dialysis of the dimeric CA increased the iodine concentration and strongly increased the viscosity at all tested osmolalities. In contrast, for the monomeric agents an increase in concentration and viscosity was observed only at 700 as well 1000 mOsm/kg H{sub 2}O but to a lesser extent. In summary, dialysis strongly enhanced the viscosity differences between the non-ionic monomeric and dimeric CAs. The administration of dimeric CAs leads to a strong increase in urine viscosity; this was not observed for

  15. Effervescent agents in the double contrast examination of the stomach

    International Nuclear Information System (INIS)

    Virkkunen, P.; Kreula, J.

    1981-01-01

    The buffer capacities of the BaSO 4 contrast media are poor. Yet the pH changes caused by effervescent agents or gastric contents are insignificant for mucosal adsorption. The increase of the viscosity and decrease of the density impair the results of the examination. (Auth.)

  16. Non-invasive estimation of blood pressure using ultrasound contrast agents

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup; Jensen, Jørgen Arendt

    2009-01-01

    Local blood pressure measurements provide important information on the state of health of organs in the body and can be used to diagnose diseases in the heart, lungs, and kidneys. This paper presents an experimental setup for investigating the ambient pressure sensitivity of a contrast agent using...

  17. Acoustic bubble sorting for ultrasound contrast agent enrichment.

    Science.gov (United States)

    Segers, Tim; Versluis, Michel

    2014-05-21

    An ultrasound contrast agent (UCA) suspension contains encapsulated microbubbles with a wide size distribution, with radii ranging from 1 to 10 μm. Medical transducers typically operate at a single frequency, therefore only a small selection of bubbles will resonate to the driving ultrasound pulse. Thus, the sensitivity can be improved by narrowing down the size distribution. Here, we present a simple lab-on-a-chip method to sort the population of microbubbles on-chip using a traveling ultrasound wave. First, we explore the physical parameter space of acoustic bubble sorting using well-defined bubble sizes formed in a flow-focusing device, then we demonstrate successful acoustic sorting of a commercial UCA. This novel sorting strategy may lead to an overall improvement of the sensitivity of contrast ultrasound by more than 10 dB.

  18. A Proposed Computed Tomography Contrast Agent Using Carboxybetaine Zwitterionic Tantalum Oxide Nanoparticles: Imaging, Biological, and Physicochemical Performance.

    Science.gov (United States)

    FitzGerald, Paul F; Butts, Matthew D; Roberts, Jeannette C; Colborn, Robert E; Torres, Andrew S; Lee, Brian D; Yeh, Benjamin M; Bonitatibus, Peter J

    2016-12-01

    The aim of this study was to produce and evaluate a proposed computed tomography (CT) contrast agent based on carboxybetaine zwitterionic (CZ)-coated soluble tantalum oxide (TaO) nanoparticles (NPs). We chose tantalum to provide superior imaging performance compared with current iodine-based clinical CT contrast agents. We developed the CZ coating to provide biological and physical performance similar to that of current iodinated contrast agents. In addition, the aim of this study was to evaluate the imaging, biological, and physicochemical performance of this proposed contrast agent compared with clinically used iodinated agents. We evaluated CT imaging performance of our CZ-TaO NPs compared with that of an iodinated agent in live rats, imaged centrally located within a tissue-equivalent plastic phantom that simulated a large patient. To evaluate vascular contrast enhancement, we scanned the rats' great vessels at high temporal resolution during and after contrast agent injection. We performed several in vivo CZ-TaO NP studies in healthy rats to evaluate tolerability. These studies included injecting the agent at the anticipated clinical dose (ACD) and at 3 times and 6 times the ACD, followed by longitudinal hematology to assess impact to blood cells and organ function (from 4 hours to 1 week). Kidney histological analysis was performed 48 hours after injection at 3 times the ACD. We measured the elimination half-life of CZ-TaO NPs from blood, and we monitored acute kidney injury biomarkers with a kidney injury assay using urine collected from 4 hours to 1 week. We measured tantalum retention in individual organs and in the whole carcass 48 hours after injection at ACD. Carboxybetaine zwitterionic TaO NPs were synthesized and analyzed in detail. We used multidimensional nuclear magnetic resonance to determine surface functionality of the NPs. We measured NP size and solution properties (osmolality and viscosity) of the agent over a range of tantalum concentrations

  19. Safety of contrast media. Focus on contrast-induced nephropathy (CIN)

    International Nuclear Information System (INIS)

    Kuwatsuru, Ryohei

    2011-01-01

    Despite advances in imaging diagnosis, contrast media still play an important role in diagnosing the existence of the disease, demonstrating the extent of disease, and determining the perfusion of the disease, which is important to make a differential diagnosis. However, the administration of contrast media may cause contrast-induced nephropathy (CIN), especially in patients with renal impairment. It is estimated that 20-30% of patients with renal impairment who received contrast media develop CIN. Though the precise cause of CIN currently remains unknown, almost all injected contrast media are excreted through the kidney and the effects of contrast media on the kidney are easily understood. As CIN is the most common cause of death due to complications after receiving contrast media, prevention of CIN is important. There are several known risk factors for CIN. Patients with renal impairment, diabetes mellitus, and dehydration are at high risk for CIN. Furthermore, a high osmolar contrast media, excessive amount of contrast media, and ionic contrast media are also risk factors for CIN. CIN can be prevented in several ways. Certain drugs seem to be useful to prevent CIN, while others are harmful. Hydration is useful to prevent CIN, although there is no widely acceptable hydration method to prevent CIN. Both sodium bicarbonate and N-acetylcysteine are promising candidates for prevention of CIN. There are few reports to study CIN after intravenous administration, although reports of CIN after percutaneous cardiac intervention (PCI) and angiography are well recognized. In clinical situations, intravenous administration of contrast media is common. Therefore, a study of CIN after intravenous administration of contrast media should be performed. (author)

  20. Synthesis Of Gd-dtpa-folat For Magnetic Resonance Imaging Contrast Agent And Characterization By Using 153gd-dtpa-folate Radioactive

    OpenAIRE

    G., Adang H; S., Yono; Maskur

    2012-01-01

    Contrast agent was used to clarify the image of the organ that is difficult to distinguish by MRI (Magnetic Resonance Imaging) techniques, particularly in soft tissues of the central nervous system, liver, digestive system, lymphatic system, breast, cardiovascular and pulmonary systems. One of the commonly used contrast agents in hospitals is Gadolinium-DieThylenetriamine Pentaacetic Acid (Gd-DTPA). Gd-DTPA is non specific contrast agent, therefore it has led to develop a contrast agent that ...

  1. Chitosan-coated nickel-ferrite nanoparticles as contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ahmad, Tanveer; Bae, Hongsub; Iqbal, Yousaf; Rhee, Ilsu; Hong, Sungwook; Chang, Yongmin; Lee, Jaejun; Sohn, Derac

    2015-01-01

    We report evidence for the possible application of chitosan-coated nickel-ferrite (NiFe 2 O 4 ) nanoparticles as both T 1 and T 2 contrast agents in magnetic resonance imaging (MRI). The coating of nickel-ferrite nanoparticles with chitosan was performed simultaneously with the synthesis of the nickel-ferrite nanoparticles by a chemical co-precipitation method. The coated nanoparticles were cylindrical in shape with an average length of 17 nm and an average width of 4.4 nm. The bonding of chitosan onto the ferrite nanoparticles was confirmed by Fourier transform infrared spectroscopy. The T 1 and T 2 relaxivities were 0.858±0.04 and 1.71±0.03 mM −1 s −1 , respectively. In animal experimentation, both a 25% signal enhancement in the T 1 -weighted mage and a 71% signal loss in the T 2 -weighted image were observed. This demonstrated that chitosan-coated nickel-ferrite nanoparticles are suitable as both T 1 and T 2 contrast agents in MRI. We note that the applicability of our nanoparticles as both T 1 and T 2 contrast agents is due to their cylindrical shape, which gives rise to both inner and outer sphere processes of nanoparticles. - Highlights: • Chitosan-coated nickel-ferrite (Ni-Fe 2 O 4 ) nanoparticles were synthesized in an aqueous system by chemical co-precipitation. • The characterization of bare and chitosan-coated nanoparticles were performed using various analytical tools, such as TEM, FTIR, XRD, and VMS. • We evaluated the coated particles as potential T 1 and T 2 contrast agents for MRI by measuring T 1 and T 2 relaxation times as a function of iron concentration. • Both T 1 and T 2 effects were also observed in animal experimentation

  2. Renal perfusion image using harmonic ultrasound with microbble contrast agent: preliminary study

    International Nuclear Information System (INIS)

    Kim, Jung Hoon; Choi, Jae Ho; Han, Dong Chul; Lee, Hi Bahl; Choi, Deuk Lin; Eun, Hyo Won; Lee, Hun Jae

    2003-01-01

    To compare, in terms of their feasibility and normal range, 99m Tc-DTPA renal perfusion imaging and renal perfusion imaging using harmonic ultrasound (US) with a microbubble contrast agent for the evaluation of renal perfusion after renal transplantation. During a six-month period, thirty patients who had received a renal transplant underwent both 99m Tc-DTPA renal perfusion imaging and renal perfusion imaging using harmonic US with a microbubble contrast agent. Sonographic renal perfusion images were obtained before and after a bolus injection of the microbubble contrast agent Levovist TM (SH U 5084; Schering AG, Berlin, Germany) every 3 seconds for 3 minutes. Sonographic renal perfusion images were converted into a renal perfusion curve by a computer program and T peak of the curve thus obtained was compared with that of the 99m Tc-DTPA curve. Average T peak of the 99m Tc-DTPA renal perfusion curve was 16.2 seconds in the normal group and 39.6 seconds in the delayed perfusion group, while average T peak of the sonographic renal perfusion curve was 23.7 seconds and 46.2 seconds, respectively. T peak of the sonographic renal perfusion curve showed a good correlation with that of the 99m Tc-DTPA curve (correlation coefficient=0.8209; p=0.0001). The cut-off value of T peak of the sonographic renal perfusion curve was 35 seconds (sensitivity=90%, specificity=95%). In patients who have received a renal transplant, the findings of renal perfusion imaging using harmonic US with a microbubble contrast agent show close correlation with those of 99m Tc-DTPA renal perfusion imaging. The optimal cut-off value of T peak of the sonographic renal perfusion curve was 35 seconds

  3. Evaluation of chirp reversal power modulation sequence for contrast agent imaging

    International Nuclear Information System (INIS)

    Novell, A; Sennoga, CA; Escoffre, JM; Chaline, J; Bouakaz, A

    2014-01-01

    Over the last decade, significant research effort has been focused on the use of chirp for contrast agent imaging because chirps are known to significantly increase imaging contrast-to-noise ratio (CNR). New imaging schemes, such as chirp reversal (CR), have been developed to improve contrast detection by increasing non-linear microbubble responses. In this study we evaluated the contrast enhancement efficiency of various chirped imaging sequences in combination with well-established imaging schemes such as power modulation (PM) and pulse inversion (PI). The imaging schemes tested were implemented on a fully programmable open scanner and evaluated by ultrasonically scanning (excitation frequency of 2.5 MHz; amplitude of 350 kPa) a tissue-mimicking flow phantom comprising a 4 mm diameter tube through which aqueous dispersions (dilution fraction of 1/2000) of the commercial ultrasound contrast agent, SonoVue ® were continuously circulated. The recovery of non-linear microbubble responses after chirp compression requires the development and the optimization of a specific filter. A compression filter was therefore designed and used to compress and extract several non-linear components from the received microbubble responses. The results showed that using chirps increased the image CNR by approximately 10 dB, as compared to conventional Gaussian apodized sine burst excitation but degraded the axial resolution by a factor of 1.4, at −3 dB. We demonstrated that the highest CNR and contrast-to-noise ratio (CTR) were achievable when CR was combined with PM as compared to other imaging schemes such as PI. (paper)

  4. Synthesis of functionalized magnetite nanoparticles to use as liver targeting MRI contrast agent

    International Nuclear Information System (INIS)

    Yazdani, Farshad; Fattahi, Bahare; Azizi, Najmodin

    2016-01-01

    The aim of this research was the preparation of functionalized magnetite nanoparticles to use as a liver targeting contrast agent in magnetic resonance imaging (MRI). For this purpose, Fe_3O_4 nanoparticles were synthesized via the co-precipitation method. The synthesized nanoparticles were coated with silica via the Stober method and finally the coated nanoparticles were functionalized with mebrofenin. Formation of crystalline magnetite particles was confirmed by X-ray diffraction (XRD) analysis. The Fourier transform infrared spectroscopy (FTIR) and energy dispersive X-ray analyzer (EDX) of the final product showed that silica had been effectively bonded onto the surface of the magnetite nanoparticles and the coated nanoparticles functionalized with mebrofenin. The magnetic resonance imaging of the functional nanoparticles showed that the Fe_3O_4–SiO_2-mebrofenin composite is an effective MRI contrast agent for liver targeting. - Highlights: • Superparamagnetic magnetite nanoparticles have been synthesized by simple and economical method. • Preperation of functional MNPs as a MRI contrast agent for liver targeting. • Gaining a good r_2 relaxivity of the coated functional nanoparticles.

  5. PEGylated chitosan grafted with polyamidoaminedendron as tumor-targeted magnetic resonance imaging contrast agent

    International Nuclear Information System (INIS)

    Guangyue Zu; Xiaoyan Tong; Yi Cao; Ye Kuang; Yajie Zhang; Min Liu; Renjun Pei

    2017-01-01

    Macromolecular contrast agents labeled with targeting ligands are now receiving growing interest in tumor-targeted magnetic resonance imaging. In this study, a macromolecular contrast agent based on PEGylated chitosan was synthesized and characterized, and its application as an MRI contrast agent was then demonstrated both in vitro and in vivo. First, the chitosan backbone was partially grafted with poly(ethylene glycol), which was used to improve the in vivo stability, followed by modifying with azide groups. Second, alkynyl-terminated PAMAM dendron modified with gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) was synthesized and conjugated onto the chitosan backbone through click chemistry. Finally, the obtained mCA was further functionalized with folic acid to improve the target specificity. The obtained FA labeled mCA exhibited higher relaxivity (9.53 mM"-"1.s"-"1) relative to Gd-DTPA (4.25 mM"-"1.s"-"1) and showed negligible toxicity as determined by the WST assay. In vivo MRI results suggested that a relatively high signal enhancement was observed in the tumor region, which made it a promising candidate for tumor-targeted MRI CA. (authors)

  6. Fabrication and evaluation of tumor-targeted positive MRI contrast agent based on ultrasmall MnO nanoparticles.

    Science.gov (United States)

    Huang, Haitao; Yue, Tao; Xu, Ke; Golzarian, Jafar; Yu, Jiahui; Huang, Jin

    2015-07-01

    Gd(III) chelate is currently used as positive magnetic resonance imaging (MRI) contrast agent in clinical diagnosis, but generally induces the risk of nephrogenic systemic fibrosis (NSF) due to the dissociated Gd(3+) from Gd(III) chelates. To develop a novel positive MRI contrast agent with low toxicity and high sensitivity, ultrasmall MnO nanoparticles were PEGylated via catechol-Mn chelation and conjugated with cRGD as active targeting function to tumor. Particularly, the MnO nanoparticles with a size of ca. 5nm were modified by α,β-poly(aspartic acid)-based graft polymer containing PEG and DOPA moieties and, meanwhile, conjugated with cRGD to produce the contrast agent with a size of ca. 100nm and a longitudinal relaxivity (r1) of 10.2mM(-1)S(-1). Such nanoscaled contrast agent integrated passive- and active-targeting function to tumor, and its efficient accumulation behavior in tumor was verified by in vivo distribution study. At the same time, the PEG moiety played a role of hydrophilic coating to improve the biocompatibility and stability under storing and physiological conditions, and especially might guarantee enough circulation time in blood. Moreover, in vivo MRI revealed a good and long-term effect of enhancing MRI signal for as-fabricated contrast agent while cell viability assay proved its acceptable cytotoxicity for MRI application. On the whole, the as-fabricated PEGylated and cRGD-functionalized contrast agent based on ultrasmall MnO nanoparticles showed a great potential to the T1-weighted MRI diagnosis of tumor. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  7. Diethylenetriaminepentaacetic acid-gadolinium (DTPA-Gd)-conjugated polysuccinimide derivatives as magnetic resonance imaging contrast agents.

    Science.gov (United States)

    Lee, Ha Young; Jee, Hye Won; Seo, Sung Mi; Kwak, Byung Kook; Khang, Gilson; Cho, Sun Hang

    2006-01-01

    Biocompatible polysuccinimide (PSI) derivatives conjugated with diethylenetriaminepentaacetic acid gadolinium (DTPA-Gd) were prepared as magnetic resonance imaging (MRI) contrast agents. In this study, we synthesized PSI derivatives incorporating methoxy-poly(ethylene glycol) (mPEG) as hydrophilic ligand, hexadecylamine as hydrophobic ligand, and DTPA-Gd as contrast agent. PSI was synthesized by the polycondensation polymerization of aspartic acid. All the synthesized materials were characterized by proton nuclear magnetic resonance (1H NMR). Critical micellization concentrations were determined using fluorescent probes (pyrene). Micelle size and shape were measured by electro-photometer light scattering (ELS) and atomic force microscopy (AFM). The formed micelle size ranged from 100 to 300 nm. The T1-weighted MR images of the phantom prepared with PSI-mPEG-C16-(DTPA-Gd) were obtained in a 3.0 T clinical MR imager, and the conjugates showed a great potential as MRI contrast agents.

  8. Adherence of radiopharmaceuticals and labeled cells to intravenous tubing

    International Nuclear Information System (INIS)

    Segall, G.M.; Gurevich, N.; McDougall, I.R.

    1986-01-01

    A survey of 67 nuclear medicine departments revealed no agreement on which radiolabeled agents could be injected through intravenous lines (IVs) and which required direct venipuncture. Labeled cells and several common radiopharmaceuticals were tested for adherence to intravenous tubing. Residual activity remaining in the tubing after an adequate flush was less than 1% of the injected dose in each case. Administration of radiolabeled agents through existing IVs is an acceptable alternative to direct venipuncture in many cases

  9. Beat frequency ultrasonic microsphere contrast agent detection system

    Science.gov (United States)

    Pretlow, III, Robert A. (Inventor); Yost, William T. (Inventor); Cantrell, Jr., John H. (Inventor)

    1997-01-01

    A system for and method of detecting and measuring concentrations of an ultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two impinging signals with non-identical frequencies are combined by mixing. These beat frequencies can be used for a variety of applications such as detecting the presence of and measuring the flow rates of biological fluids and industrial liquids, including determining the concentration level of microspheres in the myocardium.

  10. Semiconducting polymer dot as a highly effective contrast agent for photoacoustic imaging

    Science.gov (United States)

    Yuan, Zhen; Zhang, Jian

    2018-02-01

    In this study, we developed a novel PIID-DTBT based semiconducting polymer dots (Pdots) that have broad and strong optical absorption in the visible-light region (500 nm - 700 nm). Gold nanoparticles (GNPs) and gold nanorods (GNRs) that have been verified as an excellent photoacoustic contrast agent were compared with Pdots based on photoacoustic imaging method. Both ex vivo and in vivo experiment demonstrated Pdots have a better photoacoustic conversion efficiency at 532 nm than GNPs and similar photoacoustic performance with GNRs at 700 nm at the same mass concentration. Our work demonstrates the great potential of Pdots as a highly effective contrast agent for precise localization of lesions relative to the blood vessels based on photoacoustic tomography imaging.

  11. The effects of X-ray energy and an iodine-based contrast agent on chromosome aberrations

    International Nuclear Information System (INIS)

    Matsubara, Sho; Kubota, Nobuo; Katoh, Tsuguhisa; Yoshino, Norio; Sasaki, Takehito; Sasaki, Masao S.

    1994-01-01

    A study was undertaken to evaluate the effect of combining irradiation with X rays of various energies and an iodine-based contrast agent on the induction of chromosome aberrations in the peripheral lymphocytes of blood samples taken from healthy young donors. Although no enhancement of the effect of radiation was induced when blood samples with the iodine-based contrast agent were given 35 kV X irradiation, an 80 kV X-ray exposure induced an enhanced level of chromosome aberrations, and a 250 kV X irradiation, an enhancement of the frequencies of chromosome aberrations was seen in blood samples with the iodine-based contrast agent, especially when a Lucite phantom was employed in studies to increase the scattered rays. It was thus shown by microdosimetric analysis that X irradiation combined with an iodine-based contrast agent causes an enhancement of the absorbed radiation dose, which is dependent on the X-ray energies employed. This phenomenon may have clinical use in the radiotherapeutic management of tumors, although further extensive studies of tumor vascularity must be pursued before this can be applied clinically. 21 refs., 8 figs., 3 tabs

  12. Interaction of a high-order Bessel beam with a submerged spherical ultrasound contrast agent shell - Scattering theory.

    Science.gov (United States)

    Mitri, F G

    2010-03-01

    Acoustic scattering properties of ultrasound contrast agents are useful in extending existing or developing new techniques for biomedical imaging applications. A useful first step in this direction is to investigate the acoustic scattering of a new class of acoustic beams, known as helicoidal high-order Bessel beams, to improve the understanding of their scattering characteristics by an ultrasound contrast agent, which at present is very limited. The transverse acoustic scattering of a commercially available albuminoidal ultrasound contrast agent shell filled with air or a denser gas such as perfluoropropane and placed in a helicoidal Bessel beam of any order is examined numerically. The shell is assumed to possess an outer radius a=3.5 microns and a thickness of approximately 105 nm. Moduli of the total and resonance transverse acoustic scattering form functions are numerically evaluated in the bandwidth 0scattering of a helicoidal Bessel beam of order m1 so that the dynamics of contrast agents would be significantly altered. The main finding of the present theory is the suppression or enhancement for a particular resonance that may be used to advantage in imaging with ultrasound contrast agents for clinical applications. 2009 Elsevier B.V. All rights reserved.

  13. A respiration-metabolism chamber system and a GC-MS method developed for studying exhalation of perfluorobutane in rats after intravenous injection of the ultrasound contrast agent Sonazoid.

    Science.gov (United States)

    Uran, Steinar; Landmark, Kristin; Normann, Per Trygve; Hals, Petter-Arnt; Toft, Kim Gunnar; Skotland, Tore

    2005-09-15

    Sonazoid is a new contrast agent for ultrasound imaging comprising an aqueous suspension of lipid-stabilised perfluorobutane (PFB) gas microbubbles. A respiration-metabolism chamber system was developed to collect exhaled air following intravenous administration of Sonazoid to rats. Analysis of PFB in the exhaled rat air was performed using a modified version of an earlier published method for blood samples, i.e. an automatic headspace gas chromatographic mass spectrometric (GC-MS) method using electron impact ionisation. The calibration standards were PFB diluted in air (2.5-1800 pg/ml). Perfluoropentane (PFP) was used as an internal standard and the MS detector was set to single ion monitoring of the base fragment ions of PFB (m/z 69 and 119) and PFP (m/z 69). The calibration curve, made by plotting the peak area ratios of PFB (m/z 69) to PFP (m/z 69) against the theoretical concentration of PFB, was fitted to a linear equation with weighting 1/y2 and found to be reproducible. The lower limit of quantification (LLOQ) was 2.5 pg PFB/ml. The between-day variation of the method was below 2.6% relative standard deviation (R.S.D.) and the within-day variation of the method was below 6.4% R.S.D. The accuracy of the method was evaluated and showed a relative error less than 5.2%. PFB was found to be stable for 14 days when stored in Tedlar sample bags at room temperature. An even lower detection limit may be obtained by using the more time-consuming process of solid-phase micro extraction; thus, by concentrating PFB on carboxen-PDMS fibres an LLOQ of 0.5 pg PFB/ml was obtained. When five rats were given an i.v. bolus injection of Sonazoid at a dose of 8 microl microbubbles/kg a mean recovery of 96% (range, 81-110%) was found during 24 h; more than 50% was exhaled during the first 30 min after injection.

  14. MRI contrast agent for targeting glioma: interleukin-13 labeled liposome encapsulating gadolinium-DTPA.

    Science.gov (United States)

    Liu, Xiaoli; Madhankumar, Achuthamangalam B; Miller, Patti A; Duck, Kari A; Hafenstein, Susan; Rizk, Elias; Slagle-Webb, Becky; Sheehan, Jonas M; Connor, James R; Yang, Qing X

    2016-05-01

    Detection of glioma with MRI contrast agent is limited to cases in which the blood-brain barrier (BBB) is compromised as contrast agents cannot cross the BBB. Thus, an early-stage infiltrating tumor is not detectable. Interleukin-13 receptor alpha 2 (IL-13Rα2), which has been shown to be overexpressed in glioma, can be used as a target moiety. We hypothesized that liposomes conjugated with IL-13 and encapsulating MRI contrast agent are capable of passing through an intact BBB and producing MRI contrast with greater sensitivity. The targeted MRI contrast agent was created by encapsulating Magnevist (Gd-DTPA) into liposomes conjugated with IL-13 and characterized by particle size distribution, cytotoxicity, and MRI relaxivity. MR image intensity was evaluated in the brain in normal mice post injection of Gd-DTPA and IL-13-liposome-Gd-DTPA one day apart. The specificity for glioma detection by IL-13-liposome-Gd-DTPA was demonstrated in an intracranial glioma mouse model and validated histologically. The average size of IL-13-liposome-Gd-DTPA was 137 ± 43 nm with relaxivity of 4.0 ± 0.4 L/mmole-s at 7 Tesla. No significant cytotoxicity was observed with MTS assay and serum chemistry in mice. The MRI signal intensity was enhanced up to 15% post injection of IL-13-liposome-Gd-DTPA in normal brain tissue following a similar time course as that for the pituitary gland outside of the BBB. MRI enhanced by IL-13-liposome-Gd-DTPA detected small tumor masses in addition to those seen with Magnevist-enhanced MRI. IL-13-liposome-Gd-DTPA is able to pass through the uncompromised BBB and detect an early stage glioma that cannot be seen with conventional contrast-enhanced MRI. © The Author(s) 2015. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Topical contrast agents to improve soft-tissue contrast in the upper airway using cone beam CT: a pilot study.

    Science.gov (United States)

    Alsufyani, N A; Noga, M L; Finlay, W H; Major, P W

    2013-01-01

    The purpose of this study is to explore the topical use of radiographic contrast agents to enhance soft-tissue contrast on cone beam CT (CBCT) images. Different barium sulphate concentrations were first tested using an airway phantom. Different methods of barium sulphate application (nasal drops, syringe, spray and sinus wash) were then tested on four volunteers, and nebulized iodine was tested in one volunteer. CBCT images were performed and then assessed subjectively by two examiners for contrast agent uniformity and lack of streak artefact. 25.0% barium sulphate presented adequate viscosity and radiodensity. Barium sulphate administered via nasal drops and sprays showed non-uniform collection at the nostrils, along the inferior and/or middle nasal meatuses and posterior nasal choana. The syringe and sinus wash showed similar results with larger volumes collecting in the naso-oropharynx. Nebulized iodine failed to distribute into the nasal cavity and scarcely collected at the nostrils. All methods of nasal application failed to adequately reach or uniformly coat the nasal cavity beyond the inferior nasal meatuses. The key factors to consider for optimum topical radiographic contrast in the nasal airway are particle size, flow velocity and radio-opacity.

  16. Preclinical investigation to compare different gadolinium-based contrast agents regarding their propensity to release gadolinium in vivo and to trigger nephrogenic systemic fibrosis-like lesions

    International Nuclear Information System (INIS)

    Sieber, Martin A.; Frenzel, Thomas; Golfier, Sven; Weinmann, Hanns-Joachim; Pietsch, Hubertus; Lengsfeld, Philipp; Schmitt-Willich, Heribert; Siegmund, Fred; Walter, Jakob

    2008-01-01

    Recent reports suggest that nephrogenic systemic fibrosis (NSF) is associated with the administration of gadolinium (Gd)-based contrast agents (GBCAs) and in particular with the stability of the Gd-complex. The aim of this investigation was to compare GBCAs and their potential to trigger NSF. Forty-two healthy male rats received repeated intravenous injections of six different GBCAs at high doses to simulate the exposure seen in patients with severe renal dysfunction. Histopathological and immunohistochemical analysis of the skin was performed, and the concentrations of Gd, zinc and copper were measured in several tissues by inductive coupled plasma atomic emission spectroscopy. Macroscopic and histological skin changes similar to those seen in NSF patients were only observed in rats receiving Omniscan. In addition, very high concentrations of Gd were observed in the animals treated with Omniscan, and, to a lesser extent, in animals treated with OptiMARK. Significantly lower levels of Gd were found after the treatment with ionic linear agents and even less after the treatment with macrocyclic agents. The data in this investigation strongly suggest that the stability of the Gd-complex is a key factor for the development of NSF-like symptoms in this experimental setting. (orig.)

  17. Preclinical investigation to compare different gadolinium-based contrast agents regarding their propensity to release gadolinium in vivo and to trigger nephrogenic systemic fibrosis-like lesions

    Energy Technology Data Exchange (ETDEWEB)

    Sieber, Martin A.; Frenzel, Thomas; Golfier, Sven; Weinmann, Hanns-Joachim; Pietsch, Hubertus [Bayer Schering Pharma AG, TRG Diagnostic Imaging, Berlin (Germany); Lengsfeld, Philipp [Bayer Schering Pharma AG, GMA DG Diagnostic Imaging, Berlin (Germany); Schmitt-Willich, Heribert [Bayer Schering Pharma AG, GDD Diagnostic Imaging, Berlin (Germany); Siegmund, Fred; Walter, Jakob [Bayer Schering Pharma AG, Nonclinical Drug Safety, Berlin (Germany)

    2008-10-15

    Recent reports suggest that nephrogenic systemic fibrosis (NSF) is associated with the administration of gadolinium (Gd)-based contrast agents (GBCAs) and in particular with the stability of the Gd-complex. The aim of this investigation was to compare GBCAs and their potential to trigger NSF. Forty-two healthy male rats received repeated intravenous injections of six different GBCAs at high doses to simulate the exposure seen in patients with severe renal dysfunction. Histopathological and immunohistochemical analysis of the skin was performed, and the concentrations of Gd, zinc and copper were measured in several tissues by inductive coupled plasma atomic emission spectroscopy. Macroscopic and histological skin changes similar to those seen in NSF patients were only observed in rats receiving Omniscan. In addition, very high concentrations of Gd were observed in the animals treated with Omniscan, and, to a lesser extent, in animals treated with OptiMARK. Significantly lower levels of Gd were found after the treatment with ionic linear agents and even less after the treatment with macrocyclic agents. The data in this investigation strongly suggest that the stability of the Gd-complex is a key factor for the development of NSF-like symptoms in this experimental setting. (orig.)

  18. High frequency nonlinear scattering from a micrometer to submicrometer sized lipid encapsulated contrast agent

    NARCIS (Netherlands)

    Goertz, David E.; Frijlink, Martijn E.; de Jong, N.; van der Steen, A.F.W.

    2006-01-01

    An experimental lipid encapsulated contrast agent comprised substantially of micrometer to submicrometer diameter bubbles was evaluated for its capacity to produce nonlinear scattering in response to high transmit frequencies. Agent characterization experiments were conducted at transmit frequencies

  19. Contrast-enhanced MR imaging monitoring of acute tumor response to chemotherapy

    International Nuclear Information System (INIS)

    Ranney, D.F.; Cohen, J.M.; Antich, P.P.; Endman, W.A.; Kulkarni, P.; Weinreb, J.C.; Giovanella, B.

    1987-01-01

    Treatment responses of human malignant melanomas were monitored at millimeter resolution in athymic mice by injecting a new polymeric contrast agent, Gd-DTPA-dextran (0.1 mmol Gd/kg, intravenously). Proton MR imaging (0.35 T, spin-echo, repetition time = 0.5 second, echo time = 50 msec) was performed 30 hours after administering diphtheria toxin. Pre-contrast medium images revealed only homogeneous intermediate-intensity tumor masses. Post-contrast medium images of untreated (viable) tumors demonstrated 32% enhancement throughout the entire mass. Post-contrast medium images of toxin-treated tumors revealed marked enhancement (65%) of the histologically viable outer rims, lesser enhancement (38%) of heavily damaged subregions, and no enhancement of dead tumor. These acute, contrast medium-enhanced MR images accurately identified tumor subregions that survived for longer than one week

  20. Contrast-enhanced harmonic ultrasound imaging in ablation therapy for primary hepatocellular carcinoma.

    Science.gov (United States)

    Minami, Yasunori; Kudo, Masatoshi

    2009-12-31

    The success rate of percutaneous radiofrequency (RF) ablation for hepatocellular carcinoma (HCC) depends on correct targeting via an imaging technique. However, RF electrode insertion is not completely accurate for residual HCC nodules because B-mode ultrasound (US), color Doppler, and power Doppler US findings cannot adequately differentiate between treated and viable residual tumor tissue. Electrode insertion is also difficult when we must identify the true HCC nodule among many large regenerated nodules in cirrhotic liver. Two breakthroughs in the field of US technology, harmonic imaging and the development of second-generation contrast agents, have recently been described and have demonstrated the potential to dramatically broaden the scope of US diagnosis of hepatic lesions. Contrast-enhanced harmonic US imaging with an intravenous contrast agent can evaluate small hypervascular HCC even when B-mode US cannot adequately characterize tumor. Therefore, contrast-enhanced harmonic US can facilitate RF ablation electrode placement in hypervascular HCC, which is poorly depicted by B-mode US. The use of contrast-enhanced harmonic US in ablation therapy for liver cancer is an efficient approach.

  1. Contrast agents and cardiac MR imaging of myocardial ischemia: from bench to bedside

    International Nuclear Information System (INIS)

    Croisille, Pierre; Revel, Didier; Saeed, Maythem

    2006-01-01

    This review paper presents, in the first part, the different classes of contrast media that are already used or are in development for cardiac magnetic resonance imaging. A classification of the different types of contrast media is proposed based on the distribution of the compounds in the body, their type of relaxivity and their potential affinity to particular molecules. In the second part, the different uses of the extracellular type of T1-enhancing contrast agent for myocardial imaging is covered from the detection of stable coronary artery disease to the detection and characterization of chronic infarction. A particular emphasis is placed on the clinical use of gadolinium-chelates, which are the universally used type of MRI contrast agent in the clinical routine. Both approaches, first-pass magnetic resonance imaging (FP-MRI) as well as delayed-enhanced magnetic resonance imaging (DE-MRI), are covered in the different situations of acute and chronic myocardial infarction. (orig.)

  2. Impact of gadolinium-based contrast agent in the assessment of Crohn's disease activity: Is contrast agent injection necessary?

    Science.gov (United States)

    Quaia, Emilio; Sozzi, Michele; Gennari, Antonio Giulio; Pontello, Michele; Angileri, Roberta; Cova, Maria Assunta

    2016-03-01

    To determine whether magnetic resonance enterography (MRE) performed without intravenous contrast injection is diagnostically noninferior to conventional contrast-enhanced MRE (CE-MRE) in patients with Crohn's disease (CD). This was an Institutional Review Board (IRB)-approved retrospective study. Ninety-six patients (52 male and 44 female; 47.18 years ± 13.6) with a diagnosis of CD underwent MRE at 1.5T including T2 -weighted single-shot turbo-spin-echo, T2 -weighted spectral fat presaturation with inversion recovery (SPAIR), T1 -weighted balanced fast-field-echo MR sequences, and CE-MRE consisting in T1 -weighted breath-hold THRIVE 3D MRI sequences after administration of gadobenate dimeglumine (0.2 mL/kg of body weight). Unenhanced MRE, CE-MRE, and unenhanced MRE plus CE-MRE were reviewed in separate sessions with blinding by two readers in consensus, and subsequently by two other readers independently considering a subgroup of 20 patients. Crohn's Disease Endoscopic Index of Severity (CDEIS) and/or histologic analysis of the surgical specimen were considered as reference standards for the assessment of inflammatory activity. Patients revealed prevalently active (n = 55 patients) or quiescent CD (n = 41 patients). The agreement between unenhanced MRE vs. CE-MRE in interpreting active bowel inflammation was 96% (123/128 bowel segments; one-sided 95% confidence interval [CI], >94.4%). Unenhanced MRE vs. CE-MRE vs. unenhanced MRE plus CE-MRE revealed a diagnostic accuracy of 93% [90/96] vs. 92% [88/96] vs. 97% [93/96] (P > 0.05) in the diagnosis of active CD. Interreader agreement was very good for all variables (κ value = 0.8-0.9) except for the measurement of the length of disease (κ value = 0.45). Unenhanced MRE was noninferior to CE-MRE in diagnosing active inflammation in patients with CD. © 2015 Wiley Periodicals, Inc.

  3. Do intravenous N-acetylcysteine and sodium bicarbonate prevent high osmolal contrast-induced acute kidney injury? A randomized controlled trial.

    Directory of Open Access Journals (Sweden)

    Antonio Jose Inda-Filho

    Full Text Available N-acetylcysteine (NAC or sodium bicarbonate (NaHCO3, singly or combined, inconsistently prevent patients exposed to radiographic contrast media from developing contrast-induced acute kidney injury (CI-AKI.We asked whether intravenous isotonic saline and either NaHCO3 in 5% dextrose or else a high dose of NAC in 5% dextrose prevent CI-AKI in outpatients exposed to high-osmolal iodinated contrast medium more than does saline alone.This completed prospective, parallel, superiority, open-label, controlled, computer-randomized, single-center, Brazilian trial (NCT01612013 hydrated 500 adult outpatients (214 at high risk of developing CI-AKI exposed to ioxitalamate during elective coronary angiography and ventriculography. From 1 hour before through 6 hours after exposure, 126 patients (group 1 received a high dose of NAC and saline, 125 (group 2 received NaHCO3 and saline, 124 (group 3 received both treatments, and 125 (group 4 received only saline.Groups were similar with respect to age, gender, weight, pre-existing renal dysfunction, hypertension, medication, and baseline serum creatinine and serum cystatin C, but diabetes mellitus was significantly less prevalent in group 1. CI-AKI incidence 72 hours after exposure to contrast medium was 51.4% (257/500, measured as serum creatinine > (baseline+0.3 mg/dL and/or serum cystatin C > (1.1 · baseline, and 7.6% (38/500, measured as both serum creatinine and serum cystatin C > (baseline+0.3 mg/dL or > (1.25 · baseline. CI-AKI incidence measured less sensitively was similar among groups. Measured more sensitively, incidence in group 1 was significantly (p<0.05 lower than in groups 2 and 3 but not group 4; adjustment for confounding by infused volume equalized incidence in groups 1 and 3.We found no evidence that intravenous isotonic saline and either NaHCO3 or else a high dose of NAC prevent CI-AKI in outpatients exposed to high osmolal iodinated contrast medium more than does saline alone

  4. Microbubble embedded with upconversion nanoparticles as a bimodal contrast agent for fluorescence and ultrasound imaging

    International Nuclear Information System (INIS)

    Jin, Birui; Lin, Min; You, Minli; Xu, Feng; Lu, Tianjian; Zong, Yujin; Wan, Mingxi; Duan, Zhenfeng

    2015-01-01

    Bimodal imaging offers additional imaging signal thus finds wide spread application in clinical diagnostic imaging. Fluorescence/ultrasound bimodal imaging contrast agent using fluorescent dyes or quantum dots for fluorescence signal has emerged as a promising method, which however requires visible light or UV irradiation resulting in photobleaching, photoblinking, auto-fluorescence and limited tissue penetration depth. To surmount these problems, we developed a novel bimodal contrast agent using layer-by-layer assembly of upconversion nanoparticles onto the surface of microbubbles. The resulting microbubbles with average size of 2 μm provide enhanced ultrasound echo for ultrasound imaging and upconversion emission upon near infrared irradiation for fluorescence imaging. The developed bimodal contrast agent holds great potential to be applied in ultrasound target technique for targeted diseases diagnostics and therapy. (paper)

  5. Silicon nanoparticles as contrast agents in the methods of optical biomedical diagnostics

    Science.gov (United States)

    Zabotnov, S. V.; Kashaev, F. V.; Shuleiko, D. V.; Gongalsky, M. B.; Golovan, L. A.; Kashkarov, P. K.; Loginova, D. A.; Agrba, P. D.; Sergeeva, E. A.; Kirillin, M. Yu

    2017-07-01

    The efficiency of light scattering by nanoparticles formed using the method of picosecond laser ablation of silicon in water and by nanoparticles of mechanically grinded mesoporous silicon is compared. The ensembles of particles of both types possess the scattering coefficients sufficient to use them as contrast agents in optical coherence tomography (OCT), particularly in the range of wavelengths 700-1000 nm, where the absorption of both silicon and most biological and mimicking tissues is small. According to the Mie theory the main contribution to the scattering in this case is made by the particles having a relatively large size (150-300 nm). In the experiments on visualising the agar phantom surface by means of OCT, the contrast of the medium boundary, provided by nanoparticles amounted to 14 dB and 30 dB for the ablated particles and the porous silicon powder, respectively. The numerical simulation of OCT images of skin in the presence of nanoparticles, confirmed the efficiency of using them as a contrast agent.

  6. T(2) relaxation time of hyaline cartilage in presence of different gadolinium-based contrast agents.

    Science.gov (United States)

    Wiener, Edzard; Settles, Marcus; Diederichs, Gerd

    2010-01-01

    The transverse relaxation time, T(2), of native cartilage is used to quantify cartilage degradation. T(2) is frequently measured after contrast administration, assuming that the impact of gadolinium-based contrast agents on cartilage T(2) is negligible. To verify this assumption the depth-dependent variation of T(2) in the presence of gadopentetate dimeglumine, gadobenate dimeglumine and gadoteridol was investigated. Furthermore, the r(2)/r(1) relaxivity ratios were quantified in different cartilage layers to demonstrate differences between T(2) and T(1) relaxation effects. Transverse high-spatial-resolution T(1)- and T(2)-maps were simultaneously acquired on a 1.5 T MR scanner before and after contrast administration in nine bovine patellae using a turbo-mixed sequence. The r(2)/r(1) ratios were calculated for each contrast agent in cartilage. Profiles of T(1), T(2) and r(2)/r(1) across cartilage thickness were generated in the absence and presence of contrast agent. The mean values in different cartilage layers were compared for global variance using the Kruskal-Wallis test and pairwise using the Mann-Whitney U-test. T(2) of unenhanced cartilage was 98 +/- 5 ms at 1 mm and 65 +/- 4 ms at 3 mm depth. Eleven hours after contrast administration significant differences (p cartilage thickness were close to 1.0 (range 0.9-1.3). At 1.5 T, T(2) decreased significantly in the presence of contrast agents, more pronounced in superficial than in deep cartilage. The change in T(2) relaxation rate was similar to the change in T(1). Cartilage T(2) measurements after contrast administration will lead to systematic errors in the quantification of cartilage degradation. 2010 John Wiley & Sons, Ltd.

  7. Dynamic contrast-enhanced magnetic resonance imaging of articular and extraarticular synovial structures of the hands in patients with psoriatic arthritis

    DEFF Research Database (Denmark)

    Cimmino, Marco Amedeo; Barbieri, Francesca; Boesen, Mikael

    2012-01-01

    Dynamic, contrast-enhanced magnetic resonance imaging (DCE-MRI), the quantification of enhancement within the synovial membrane and bone by extracting curves using fast T1-weighted sequences during intravenous administration of contrast agent, evaluates synovitis and bone marrow edema in psoriati...... arthritis (PsA). In this pilot study, we looked at possible differences between joint synovitis and tenosynovitis in PsA as compared with rheumatoid arthritis (RA)....

  8. Metal-oxo containing polymer nanobeads as potential contrast agents for magnetic resonance imaging

    Science.gov (United States)

    Pablico, Michele Huelar

    Magnetic resonance imaging (MRI) has greatly revolutionized the way diseases are detected and treated, as it is a non-invasive imaging modality solely based on the interaction of radiowaves and hydrogen nuclei in the presence of an external magnetic field. It is widely used today for the diagnosis of diseases as it offers an efficient method of mapping structure and function of soft tissues in the body. Most MRI examinations utilize paramagnetic materials known as contrast agents, which enhance the MR signal by decreasing the longitudinal (T1) and transverse (T2) relaxation times of the surrounding water protons in biological systems. This results into increased signal intensity differences thereby allowing better interpretation and analysis of pathological tissues. Contrast agents function by lowering the T1 or lowering the T2, resulting into bright and dark contrasts, respectively. The most common MRI contrast agents that are in clinical use today are gadolinium chelates and superparamagnetic iron oxide nanoparticles, both of which have their own advantages in terms of contrast enhancement properties. In the past few years, however, there has been interest in utilizing metal-containing clusters for MRI contrast enhancement as these materials bridge the gap between the constrained structure and magnetic properties of the gadolinium chelates with the superparamagnetic behavior of the iron oxide nanoparticles. Recently, metallic clusters containing Mn and Fe metal centers have received increased attention mainly because of their potential for high spin states and benign nature. In the quest to further develop novel imaging agents, this research has focused on investigating the use of metal-oxo clusters as potential contrast agents for MRI. The primary goal of this project is to identify clusters that meet the following criteria: high paramagnetic susceptibility, water-soluble, stable, cheap, contain environmentally benign metals, and easily derivatized. This work is

  9. Quantitative evaluation of contrast agent uptake in standard fat-suppressed dynamic contrast-enhanced MRI examinations of the breast.

    Science.gov (United States)

    Kousi, Evanthia; Smith, Joely; Ledger, Araminta E; Scurr, Erica; Allen, Steven; Wilson, Robin M; O'Flynn, Elizabeth; Pope, Romney J E; Leach, Martin O; Schmidt, Maria A

    2018-01-01

    To propose a method to quantify T 1 and contrast agent uptake in breast dynamic contrast-enhanced (DCE) examinations undertaken with standard clinical fat-suppressed MRI sequences and to demonstrate the proposed approach by comparing the enhancement characteristics of lobular and ductal carcinomas. A standard fat-suppressed DCE of the breast was performed at 1.5 T (Siemens Aera), followed by the acquisition of a proton density (PD)-weighted sequence, also fat suppressed. Both sequences were characterized with test objects (T 1 ranging from 30 ms to 2,400 ms) and calibration curves were obtained to enable T 1 calculation. The reproducibility and accuracy of the calibration curves were also investigated. Healthy volunteers and patients were scanned with Ethics Committee approval. The effect of B 0 field inhomogeneity was assessed in test objects and healthy volunteers. The T 1 of breast tumors was calculated at different time points (pre-, peak-, and post-contrast agent administration) for 20 patients, pre-treatment (10 lobular and 10 ductal carcinomas) and the two cancer types were compared (Wilcoxon rank-sum test). The calibration curves proved to be highly reproducible (coefficient of variation under 10%). T 1 measurements were affected by B 0 field inhomogeneity, but frequency shifts below 50 Hz introduced only 3% change to fat-suppressed T 1 measurements of breast parenchyma in volunteers. The values of T 1 measured pre-, peak-, and post-contrast agent administration demonstrated that the dynamic range of the DCE sequence was correct, that is, image intensity is approximately directly proportional to 1/T 1 for that range. Significant differences were identified in the width of the distributions of the post-contrast T 1 values between lobular and ductal carcinomas (P contrast T 1 values, potentially related to their infiltrative growth pattern. This work has demonstrated the feasibility of fat-suppressed T 1 measurements as a tool for clinical studies. The

  10. MRI observation of the light-induced release of a contrast agent from photo-controllable polymer micelles

    International Nuclear Information System (INIS)

    Lepage, Martin; Jiang Jinqiang; Babin, Jerome; Qi, Bo; Tremblay, Luc; Zhao Yue

    2007-01-01

    The encapsulation of molecules into nanocarriers is studied for its potential in delivering a high dose of anticancer drugs to a tumor, while minimizing side effects. Most systems either release their content in a non-specific manner or under specific environmental conditions such as temperature or pH. We have synthesized a novel class of photo-controllable polymer micelles that can stably encapsulate a hydrophilic compound and subsequently release it upon absorption of UV light. Here, we describe an in vitro magnetic resonance imaging assay that can evaluate the state of incorporation of a small Gd-based contrast agent. Our results indicate that the contrast agent alone can diffuse through a filter, but that the same agent incorporated into micelles cannot. After exposure to UV light, the micelles released the contrast agent, which could then diffuse through the filter. (note)

  11. Near infrared spectral polarization imaging of prostate cancer tissues using Cybesin: a receptor-targeted contrast agent

    Science.gov (United States)

    Pu, Yang; Wang, W. B.; Tang, G. C.; Liang, Kexian; Achilefu, S.; Alfano, R. R.

    2013-03-01

    Cybesin, a smart contrast agent to target cancer cells, was investigated using a near infrared (NIR) spectral polarization imaging technique for prostate cancer detection. The approach relies on applying a contrast agent that can target cancer cells. Cybesin, as a small ICG-derivative dye-peptide, emit fluorescence between 750 nm and 900 nm, which is in the "tissue optical window". Cybesin was reported targeting the over-expressed bombesin receptors in cancer cells in animal model and the human prostate cancers over-expressing bombesin receptors. The NIR spectral polarization imaging study reported here demonstrated that Cybesin can be used as a smart optical biomarker and as a prostate cancer receptor targeted contrast agent.

  12. Nephrogenic systemic fibrosis after application of gadolinium-based contrast agents - a status paper

    International Nuclear Information System (INIS)

    Heinrich, M.; Uder, M.

    2007-01-01

    Recently the association of a rare disease named ''nephrogenic systemic fibrosis'' (NSF) with the administration of gadolinium-containing contrast media, especially gadodiamide (Omniscan, GE-Healthcare), was described. NSF is a scleroderma-like disease characterised by widespread tissue fibrosis. Until now, NSF cases were observed only in patients with kidney disease. Almost all patients were suffering from chronic renal insufficiency, 90 % of them required renal replacement therapy. The true incidence of the disease is unknown. First retrospective analyses of selected collectives of patients with end-stage renal disease showed 2 - 5 % cases of NSF after administration of Gadolinium-containing contrast agents with an odds ratio of 20 - 50 in comparison to non-exposed controls. NSF is a serious adverse reaction, which may result in severe disabilities and even death. Therefore all radiologists applying gadolinium-based contrast agents should be informed about this disease and the recent recommendations for its prevention. On the basis of the published data, Omniscan should not be used in patients with severe renal impairment (GFR 2 ) and those who have had or are undergoing liver transplantation. In neonates and infants up to 1 year of age, Omniscan should only be used after careful consideration. Also the other gadolinium-based contrast agents should be used in high-risk patients only after careful consideration using the lowest dose possible

  13. In vivo photoacoustic tumor tomography using a quinoline-annulated porphyrin as NIR molecular contrast agent.

    Science.gov (United States)

    Luciano, Michael; Erfanzadeh, Mohsen; Zhou, Feifei; Zhu, Hua; Bornhütter, Tobias; Röder, Beate; Zhu, Quing; Brückner, Christian

    2017-01-25

    The synthesis and photophysical properties of a tetra-PEG-modified and freely water-soluble quinoline-annulated porphyrin are described. We previously demonstrated the ability of quinoline-annulated porphyrins to act as an in vitro NIR photoacoustic imaging (PAI) contrast agent. The solubility of the quinoline-annulated porphyrin derivative in serum now allowed the assessment of the efficacy of the PEGylated derivative as an in vivo NIR contrast agent for the PAI of an implanted tumor in a mouse model. A multi-fold contrast enhancement when compared to the benchmark dye ICG could be shown, a finding that could be traced to its photophysical properties (short triplet lifetimes, low fluorescence and singlet oxygen sensitization quantum yields). A NIR excitation wavelength of 790 nm could be used, fully taking advantage of the optical window of tissue. Rapid renal clearance of the dye was observed. Its straight-forward synthesis, optical properties with the possibility for further optical fine-tuning, nontoxicity, favorable elimination rates, and contrast enhancement make this a promising PAI contrast agent. The ability to conjugate the PAI chromophore with a fluorescent tag using a facile and general conjugation strategy was also demonstrated.

  14. EPR and DNP Properties of Certain Novel Single Electron Contrast Agents Intended for Oximetric Imaging

    DEFF Research Database (Denmark)

    Ardenkjær-Larsen, J. H.; Laursen, I; Leunbach, I.

    1998-01-01

    Parameters of relevance to oximetry with Overhauser magnetic resonance imaging (OMRI) have been measured for three single electron contrast agents of the triphenylmethyl type. The single electron contrast agents are stable and water soluble. Magnetic resonance properties of the agents have been...... examined with electron paramagnetic resonance (EPR), nuclear magnetic resonance (NMR), and dynamic nuclear polarization (DNP) at 9.5 mT in water, isotonic saline, plasma, and blood at 23 and 37°C. The relaxivities of the agents are about 0.2–0.4 mM−1s−1and the DNP enhancements extrapolate close...... to the dipolar limit. The agents have a single, narrow EPR line, which is analyzed as a Voigt function. The linewidth is measured as a function of the agent concentration and the oxygen concentration. The concentration broadenings are about 1–3 μT/mM and the Lorentzian linewidths at infinite dilution are less...

  15. Ultrasonic Analysis of Peptide- and Antibody-Targeted Microbubble Contrast Agents for Molecular Imaging of αvβ3-Expressing Cells

    Directory of Open Access Journals (Sweden)

    Paul A. Dayton

    2004-04-01

    Full Text Available The goal of targeted ultrasound contrast agents is to significantly and selectively enhance the detection of a targeted vascular site. In this manuscript, three distinct contrast agents targeted to the αvβ3 integrin are examined. The αvβ3 integrin has been shown to be highly expressed on metastatic tumors and endothelial cells during neovascularization, and its expression has been shown to correlate with tumor grade. Specific adhesion of these contrast agents to αvβ3-expressing cell monolayers is demonstrated in vitro, and compared with that of nontargeted agents. Acoustic studies illustrate a backscatter amplitude increase from monolayers exposed to the targeted contrast agents of up to 13-fold (22 dB relative to enhancement due to control bubbles. A linear dependence between the echo amplitude and bubble concentration was observed for bound agents. The decorrelation of the echo from adherent targeted agents is observed over successive pulses as a function of acoustic pressure and bubble density. Frequency–domain analysis demonstrates that adherent targeted bubbles exhibit high-amplitude narrowband echo components, in contrast to the primarily wideband response from free microbubbles. Results suggest that adherent targeted contrast agents are differentiable from free-floating microbubbles, that targeted contrast agents provide higher sensitivity in the detection of angiogenesis, and that conventional ultrasound imaging techniques such as signal subtraction or decorrelation detection can be used to detect integrin-expressing vasculature with sufficient signal-to-noise.

  16. Assessing the efficacy of nano- and micro-sized magnetic particles as contrast agents for MRI cell tracking.

    Directory of Open Access Journals (Sweden)

    Arthur Taylor

    Full Text Available Iron-oxide based contrast agents play an important role in magnetic resonance imaging (MRI of labelled cells in vivo. Currently, a wide range of such contrast agents is available with sizes varying from several nanometers up to a few micrometers and consisting of single or multiple magnetic cores. Here, we evaluate the effectiveness of these different particles for labelling and imaging stem cells, using a mouse mesenchymal stem cell line to investigate intracellular uptake, retention and processing of nano- and microsized contrast agents. The effect of intracellular confinement on transverse relaxivity was measured by MRI at 7 T and in compliance with the principles of the '3Rs', the suitability of the contrast agents for MR-based cell tracking in vivo was tested using a chick embryo model. We show that for all particles tested, relaxivity was markedly reduced following cellular internalisation, indicating that contrast agent relaxivity in colloidal suspension does not accurately predict performance in MR-based cell tracking studies. Using a bimodal imaging approach comprising fluorescence and MRI, we demonstrate that labelled MSC remain viable following in vivo transplantation and can be tracked effectively using MRI. Importantly, our data suggest that larger particles might confer advantages for longer-term imaging.

  17. Effects of gadolinium-based MRI contrast agents on liver tissue.

    Science.gov (United States)

    Mercantepe, Tolga; Tümkaya, Levent; Çeliker, Fatma Beyazal; Topal Suzan, Zehra; Çinar, Seda; Akyildiz, Kerimali; Mercantepe, Filiz; Yilmaz, Adnan

    2018-04-01

    MRI with contrast is often used clinically. However, recent studies have reported a high accumulation of gadolinium-based contrast agents (GBCAs) in kidney, liver, and spleen tissues in several mouse models. To compare the effects on liver tissue of gadolinium-based MRI contrast agents in the light of biochemical and histopathological evaluation. Institutional Review Board (IRB)-approved controlled longitudinal study. In all, 32 male Sprague-Dawley rats were divided into a healthy control group subjected to no procedure (Group 1), a sham group (Group 2), a gadodiamide group (Group 3), and a gadoteric acid group (Group 4). Not applicable. Liver tissues removed at the end of the fifth week and evaluated pathologically (scored Knodell's histological activity index [HAI] method by two histopathologists) immunohistochemical (caspase-3 and biochemical tests (AST, ALT, TAS, TOS, and OSI method by Erel et al) were obtained. Differences between groups were analyzed using the nonparametric Kruskal-Wallis test followed by the Tamhane test, and one-way analysis of variance (ANOVA) followed by Turkey's HSD test. An increase was observed in histological activity scores in sections from rats administered gadodiamide and gadoteric acid, and in caspase-3, AST and ALT values (P total antioxidant and antioxidant capacity. 1 Technical Efficacy: Stage 4 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  18. SU-F-T-664: The Efficacy of Gold Nanoparticles as Contrast Agents in Mice

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Y; Zhang, Y; Sajo, E [University of Massachusetts Lowell, Lowell, MA (United States); Yasmin-Karim, S; Karve, A [Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA (United States); Ngwa, W [University of Massachusetts Lowell, Lowell, MA (United States); Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: Micro-Computed Tomography (micro-CT) has been widely used as a non-invasive, high-resolution imaging modality in preclinical research. However, tumors cannot be well distinguished, since their density are similar to those of surrounding tissues, and the tumors’ natural contrast is very low. The benefits of using Gold Nanoparticles (AuNPs) as a promising high atomic weight contrast agent have been published in recent years. The aim of this study is to investigate the efficacy of AuNPs as contrast agents using different energy x-rays. Methods: The left flank of an immune-compromised athymic nude mouse was implanted with subcutaneous xenograft model of human lung cancer line, A549 cells (from ATCC). After 14 days, this mouse was imaged with dual energy cone-beam micro-CT. The selected energies were 45 kVp and 65 kVp. 10µg AuNPs (200 µg/ml concentration) approximately 12 nm in size were injected subcutaneously into the tumor. The mouse was imaged 0, 3 and 24 hours post-injection. During scanning, this mouse was anesthetized. All projection raw data have been optimized and then images were reconstructed with the FDK Algorithm. Results: Based on images, at 0 hour, AuNPs provided obvious contrast no matter which energy selected, 45 kVp or 65 kVp; and using 45 kVp X-ray, AuNps showed greater contrast. After 3 hours or evenand longer, AuNPs distributed throughout the whole body of mouse, and they were not shown clearly shown in the images. Conclusion: In this study, we investigated the efficacy of AuNPs as image contrast agents at different energies with dual-energy micro-CT, using 200µg/mL of AuNPs. Sufficiently high concentrations of AuNPs are needed to be able to track intratumoral distribution. Images showed good contrast immediately following the administration of the agent but results were poor after 3 hours.

  19. Gadolinium-based magnetic resonance contrast agents at 7 Tesla: in vitro T1 relaxivities in human blood plasma.

    Science.gov (United States)

    Noebauer-Huhmann, Iris M; Szomolanyi, Pavol; Juras, Vladimír; Kraff, Oliver; Ladd, Mark E; Trattnig, Siegfried

    2010-09-01

    PURPOSE/INTRODUCTION: The aim of this study was to determine the T1 relaxivities (r1) of 8 gadolinium (Gd)-based MR contrast agents in human blood plasma at 7 Tesla, compared with 3 Tesla. Eight commercially available Gd-based MR contrast agents were diluted in human blood plasma to concentrations of 0, 0.25, 0.5, 1, and 2 mmol/L. In vitro measurements were performed at 37 degrees C, on a 7 Tesla and on a 3 Tesla whole-body magnetic resonance imaging scanner. For the determination of T1 relaxation times, Inversion Recovery Sequences with inversion times from 0 to 3500 ms were used. The relaxivities were calculated. The r1 relaxivities of all agents, diluted in human blood plasma at body temperature, were lower at 7 Tesla than at 3 Tesla. The values at 3 Tesla were comparable to those published earlier. Notably, in some agents, a minor negative correlation of r1 with a concentration of up to 2 mmol/L could be observed. This was most pronounced in the agents with the highest protein-binding capacity. At 7 Tesla, the in vitro r1 relaxivities of Gd-based contrast agents in human blood plasma are lower than those at 3 Tesla. This work may serve as a basis for the application of Gd-based MR contrast agents at 7 Tesla. Further studies are required to optimize the contrast agent dose in vivo.

  20. Dual-energy CT-cholangiography in potential donors for living-related liver transplantation: Improved biliary visualization by intravenous morphine co-medication

    International Nuclear Information System (INIS)

    Sommer, C.M.; Schwarzwaelder, C.B.; Stiller, W.; Schindera, S.T.; Heye, T.; Stampfl, U.; Bellemann, N.; Holzschuh, M.; Schmidt, J.; Weitz, J.; Grenacher, L.; Kauczor, H.U.; Radeleff, B.A.

    2012-01-01

    Purpose: To prospectively evaluate whether intravenous morphine co-medication improves bile duct visualization of dual-energy CT-cholangiography. Materials and methods: Forty potential donors for living-related liver transplantation underwent CT-cholangiography with infusion of a hepatobiliary contrast agent over 40 min. Twenty minutes after the beginning of the contrast agent infusion, either normal saline (n = 20 patients; control group [CG]) or morphine sulfate (n = 20 patients; morphine group [MG]) was injected. Forty-five minutes after initiation of the contrast agent, a dual-energy CT acquisition of the liver was performed. Applying dual-energy post-processing, pure iodine images were generated. Primary study goals were determination of bile duct diameters and visualization scores (on a scale of 0 to 3: 0—not visualized; 3—excellent visualization). Results: Bile duct visualization scores for second-order and third-order branch ducts were significantly higher in the MG compared to the CG (2.9 ± 0.1 versus 2.6 ± 0.2 [P < 0.001] and 2.7 ± 0.3 versus 2.1 ± 0.6 [P < 0.01], respectively). Bile duct diameters for the common duct and main ducts were significantly higher in the MG compared to the CG (5.9 ± 1.3 mm versus 4.9 ± 1.3 mm [P < 0.05] and 3.7 ± 1.3 mm versus 2.6 ± 0.5 mm [P < 0.01], respectively). Conclusion: Intravenous morphine co-medication significantly improved biliary visualization on dual-energy CT-cholangiography in potential donors for living-related liver transplantation

  1. Dual-energy CT-cholangiography in potential donors for living-related liver transplantation: Improved biliary visualization by intravenous morphine co-medication

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, C.M., E-mail: christof.sommer@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg (Germany); Schwarzwaelder, C.B.; Stiller, W. [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg (Germany); Schindera, S.T. [Department of Diagnostic, Interventional, and Pediatric Radiology, University Hospital and University of Berne, Berne (Switzerland); Heye, T.; Stampfl, U.; Bellemann, N.; Holzschuh, M. [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg (Germany); Schmidt, J.; Weitz, J. [Department of General, Abdominal and Transplantation Surgery, University Hospital Heidelberg, Heidelberg (Germany); Grenacher, L.; Kauczor, H.U.; Radeleff, B.A. [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg (Germany)

    2012-09-15

    Purpose: To prospectively evaluate whether intravenous morphine co-medication improves bile duct visualization of dual-energy CT-cholangiography. Materials and methods: Forty potential donors for living-related liver transplantation underwent CT-cholangiography with infusion of a hepatobiliary contrast agent over 40 min. Twenty minutes after the beginning of the contrast agent infusion, either normal saline (n = 20 patients; control group [CG]) or morphine sulfate (n = 20 patients; morphine group [MG]) was injected. Forty-five minutes after initiation of the contrast agent, a dual-energy CT acquisition of the liver was performed. Applying dual-energy post-processing, pure iodine images were generated. Primary study goals were determination of bile duct diameters and visualization scores (on a scale of 0 to 3: 0—not visualized; 3—excellent visualization). Results: Bile duct visualization scores for second-order and third-order branch ducts were significantly higher in the MG compared to the CG (2.9 ± 0.1 versus 2.6 ± 0.2 [P < 0.001] and 2.7 ± 0.3 versus 2.1 ± 0.6 [P < 0.01], respectively). Bile duct diameters for the common duct and main ducts were significantly higher in the MG compared to the CG (5.9 ± 1.3 mm versus 4.9 ± 1.3 mm [P < 0.05] and 3.7 ± 1.3 mm versus 2.6 ± 0.5 mm [P < 0.01], respectively). Conclusion: Intravenous morphine co-medication significantly improved biliary visualization on dual-energy CT-cholangiography in potential donors for living-related liver transplantation.

  2. Three-dimensional contrast-enhanced MRI using an intravascular contrast agent for detection of traumatic intra-abdominal hemorrhage and abdominal parenchymal injuries: an experimental study

    International Nuclear Information System (INIS)

    Weishaupt, D.; Ruehm, S.G.; Patak, M.A.; Schmidt, M.; Debatin, J.F.; Hetzer, F.H.

    2000-01-01

    The aim of this study was to compare the performance of 3D MRI in conjunction with an intravascular contrast agent to spiral contrast-enhanced CT, regarding the detection of abdominal parenchymal injuries as well as peritoneal hemorrhage in an animal model. Liver and kidney injuries were created surgically in six female pigs under general anesthesia. All pigs underwent contrast-enhanced spiral CT and 3D MR imaging following administration of an intravascular contrast agent (NC100150 Injection). Two readers rated their confidence independently on MR and CT data sets using a five-point scale for the presence of organ injury and hemoperitoneum. Autopsy findings served as standard of reference. Sensitivity and specificity for MR in detecting hepatic and renal injuries as well as hemoperitoneum was 100 %. Computed tomography was less accurate with sensitivity and specificity values of 90 and 94 %, respectively. Receiver operating characteristics (ROC) analysis revealed a higher confidence when interpretation was based on MR images. In an animal model 3D MR imaging in conjunction with an intravascular contrast agent proved highly accurate in detecting and localizing parenchymal injuries to the upper abdomen as well as in detecting intraperitoneal blood collections. (orig.)

  3. Ultrasonically induced dynamics of a contrast agent microbubble between two parallel elastic walls

    International Nuclear Information System (INIS)

    Doinikov, Alexander A; Bouakaz, Ayache

    2013-01-01

    This work presents the derivation of a Rayleigh–Plesset-like equation that describes the radial oscillation of a contrast agent microbubble between two elastic walls, assuming that the bubble is attached to one of them. The obtained equation is then used in numerical simulations in order to establish how the presence of the second wall affects the resonance properties and the scattered echo of the contrast microbubble. The effect of encapsulation on the dynamics of the microbubble is simulated by the Marmottant shell model which is commonly used for the modeling of the dynamics of lipid-shelled contrast agents. Two cases are examined. In the first, the mechanical properties of the walls are set to correspond to OptiCell chambers which are widely used in experiments on microbubble contrast agents. In the second, the properties of the walls correspond to walls of blood vessels. It is shown that the presence of the second wall increases the resonance frequency of the contrast microbubble and decreases the amplitudes of the radial oscillation and the scattered echo of the microbubble as compared to the case that the second wall is absent. It is also shown that the presence of the second wall can change noticeably the intensity of the second harmonic in the spectrum of the scattered pressure. It is demonstrated that, depending on the value of the driving frequency, the presence of the second wall can either increase or decrease the intensity of the second harmonic as compared to its intensity in the case that the second wall is absent. (paper)

  4. Highly stable polymer coated nano-clustered silver plates: a multimodal optical contrast agent for biomedical imaging

    International Nuclear Information System (INIS)

    Ray, Aniruddha; Mukundan, Ananya; Karamchand, Leshern; Kopelman, Raoul; Xie, Zhixing; Wang, Xueding

    2014-01-01

    Here, we present a new optical contrast agent based on silver nanoplate clusters embedded inside of a polymer nano matrix. Unlike nanosphere clusters, which have been well studied, nanoplate clusters have unique properties due to the different possible orientations of interaction between the individual plates, resulting in a significant broadening of the absorption spectra. These nanoclusters were immobilized inside of a polymer cladding so as to maintain their stability and optical properties under in vivo conditions. The polymer-coated silver nanoplate clusters show a lower toxicity compared to the uncoated nanoparticles. At high nanoparticle concentrations, cell death occurs mostly due to apoptosis. These nanoparticles were used for targeted fluorescence imaging in a rat glioma cell line by incorporating a fluorescent dye into the matrix, followed by conjugation of a tumor targeting an F3 peptide. We further used these nanoparticles as photoacoustic contrast agents in vivo to enhance the contrast of the vasculature structures in a rat ear model. We observed a contrast enhancement of over 90% following the nanoparticle injection. It is also shown that these NPs can serve as efficient contrast agents, with specific targeting abilities for broadband multimodal imaging that are usable for diagnostic applications and that extend into use as therapeutic agents as well. (paper)

  5. Non-invasive ambient pressure estimation using non-linear ultrasound contrast agents

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup

    Many attempts to find a non-invasive procedure to measure the blood pressure locally in the body have been made. This dissertation focuses on the approaches which utilize highly compressible ultrasound contrast agents as ambient pressure sensors. The literature within the topic has been reviewed...

  6. Modified Gadonanotubes as a Promising Novel MRI Contrasting Agent

    OpenAIRE

    Rouzbeh Jahanbakhsh; Fatemeh Atyabi; Saeed Shanehsazzadeh; Zahra Sobhani; Mohsen Adeli; Rassoul Dinarvand

    2013-01-01

    Background and purpose of the study Carbon nanotubes (CNTs) are emerging drug and imaging carrier systems which show significant versatility. One of the extraordinary characteristics of CNTs as Magnetic Resonance Imaging (MRI) contrasting agent is the extremely large proton relaxivities when loaded with gadolinium ion (Gdn 3+) clusters. Methods In this study equated Gdn 3+ clusters were loaded in the sidewall defects of oxidized multiwalled (MW) CNTs. The amount of loaded gadolinium ion into ...

  7. Chitosan-coated nickel-ferrite nanoparticles as contrast agents in magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Tanveer [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Department of Physics, Abdul Wali Khan University, Mardan (Pakistan); Bae, Hongsub; Iqbal, Yousaf [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Rhee, Ilsu, E-mail: ilrhee@knu.ac.kr [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Hong, Sungwook [Division of Science Education, Daegu University, Gyeongsan 712-714 (Korea, Republic of); Chang, Yongmin; Lee, Jaejun [Department of Diagnostic Radiology, College of Medicine, Kyungpook National University and Hospital, Daegu 700-721 (Korea, Republic of); Sohn, Derac [Department of Physics, Hannam University, Daejon (Korea, Republic of)

    2015-05-01

    We report evidence for the possible application of chitosan-coated nickel-ferrite (NiFe{sub 2}O{sub 4}) nanoparticles as both T{sub 1} and T{sub 2} contrast agents in magnetic resonance imaging (MRI). The coating of nickel-ferrite nanoparticles with chitosan was performed simultaneously with the synthesis of the nickel-ferrite nanoparticles by a chemical co-precipitation method. The coated nanoparticles were cylindrical in shape with an average length of 17 nm and an average width of 4.4 nm. The bonding of chitosan onto the ferrite nanoparticles was confirmed by Fourier transform infrared spectroscopy. The T{sub 1} and T{sub 2} relaxivities were 0.858±0.04 and 1.71±0.03 mM{sup −1} s{sup −1}, respectively. In animal experimentation, both a 25% signal enhancement in the T{sub 1}-weighted mage and a 71% signal loss in the T{sub 2}-weighted image were observed. This demonstrated that chitosan-coated nickel-ferrite nanoparticles are suitable as both T{sub 1} and T{sub 2} contrast agents in MRI. We note that the applicability of our nanoparticles as both T{sub 1} and T{sub 2} contrast agents is due to their cylindrical shape, which gives rise to both inner and outer sphere processes of nanoparticles. - Highlights: • Chitosan-coated nickel-ferrite (Ni-Fe{sub 2}O{sub 4}) nanoparticles were synthesized in an aqueous system by chemical co-precipitation. • The characterization of bare and chitosan-coated nanoparticles were performed using various analytical tools, such as TEM, FTIR, XRD, and VMS. • We evaluated the coated particles as potential T{sub 1} and T{sub 2} contrast agents for MRI by measuring T{sub 1} and T{sub 2} relaxation times as a function of iron concentration. • Both T{sub 1} and T{sub 2} effects were also observed in animal experimentation.

  8. MR of the small bowel with a biphasic oral contrast agent (polyethylene glycol): technical aspects and findings in patients affected by Crohn's disease.

    Science.gov (United States)

    Laghi, Andrea; Paolantonio, Pasquale; Iafrate, Franco; Borrelli, Osvaldo; Dito, Lucia; Tomei, Ernesto; Cucchiara, Salvatore; Passariello, Roberto

    2003-01-01

    To report our experience using MR of the small bowel with polyethylene glycol (PEG) solution as an oral contrast agent in a population of adults and children with known Crohn's disease. 40 patients (29 males; 11 females), 15 adults (age range 24-52 years) and 25 children (age range 5-17 years), with known Crohn's disease, underwent MR of the small bowel using a supeconductive 1.5 T magnet, and polyethylene glycol solution as an oral contrast agent. The fixed amount of contrast agent was 750-1000 ml for adults and 10 ml/kg of body weight for children. The Crohn's Disease Activity Index (CDAI) was available in all patients. Our study protocol included the acquisition of T2-weighted half-Fourier single-shot turbo spin-echo (HASTE) sequences and true fast imaging in the steady-state precession (true-FISP) sequences, followed by the acquisition of "spoiled" 2D gradient echo T1-weighted sequences with fat suppression (FLASH, fast low-angle shot) or alternatively "spoiled" 3D (VIBE, volume interpolated breath-hold examination), acquired 70 seconds after intravenous administration of gadopentetate dimeglumine (Gd-DTPA) (0,1 mmol/kg). A specific MR score was created and calculated for each patient and was compared by means of the Spearman rank with CDAI. In all patients no significant side effects were observed and the MR examination was well tolerated even by paediatric patients. In all cases MR showed a small bowel wall thickening (> 4 mm) in the terminal ileum, with lumen stenosis in 26 patients. In 3 cases pathological segments proximal to the terminal ileum were observed and in another 3 cases caecal involvement was visible. The MR examination was able to show abnormalities of perivisceral fat tissue in 15 patients, mesenteric lymphadenopathy in 1 patient and abdominal abscess in 1 case. The Spearman rank showed a statistically significant correlation between CDAI and the MR score (r = 0.91, P = 0,0001). MR using PEG as an oral contrast agent could be considered a test

  9. Imaging of the Achilles tendon in spondyloarthritis: a comparison of ultrasound and conventional, short and ultrashort echo time MRI with and without intravenous contrast

    International Nuclear Information System (INIS)

    Hodgson, R.J.; Emery, P.; Grainger, A.J.; O'Connor, P.J.; Evans, R.; Coates, L.; Marzo-Ortega, H.; Helliwell, P.; McGonagle, D.; Robson, M.D.

    2011-01-01

    To compare conventional MRI, ultrashort echo time MRI and ultrasound for assessing the extent of tendon abnormalities in spondyloarthritis. 25 patients with spondyloarthritis and Achilles symptoms were studied with MRI and ultrasound. MR images of the Achilles tendon were acquired using T1-weighted spin echo, gradient echo and ultrashort echo time (UTE) sequences with echo times (TE) between 0.07 and 16 ms, before and after intravenous contrast medium. Greyscale and power Doppler ultrasound were also performed. The craniocaudal extent of imaging abnormalities measured by a consultant musculoskeletal radiologist was compared between the different techniques. Abnormalities were most extensive on spoiled gradient echo images with TE=2 ms. Contrast enhancement after intravenous gadolinium was greatest on the UTE images (TE=0.07 ms). Fewer abnormalities were demonstrated using unenhanced UTE. Abnormalities were more extensive on MRI than ultrasound. Contrast enhancement was more extensive than power Doppler signal. 3D spoiled gradient echo images with an echo time of 2 ms demonstrate more extensive tendon abnormalities than the other techniques in spondyloarthritis. Abnormalities of vascularity are best demonstrated on enhanced ultrashort echo time images. (orig.)

  10. EXCI-CEST: Exploiting pharmaceutical excipients as MRI-CEST contrast agents for tumor imaging.

    Science.gov (United States)

    Longo, Dario Livio; Moustaghfir, Fatima Zzahra; Zerbo, Alexandre; Consolino, Lorena; Anemone, Annasofia; Bracesco, Martina; Aime, Silvio

    2017-06-15

    Chemical Exchange Saturation Transfer (CEST) approach is a novel tool within magnetic resonance imaging (MRI) that allows visualization of molecules possessing exchangeable protons with water. Many molecules, employed as excipients for the formulation of finished drug products, are endowed with hydroxyl, amine or amide protons, thus can be exploitable as MRI-CEST contrast agents. Their high safety profiles allow them to be injected at very high doses. Here we investigated the MRI-CEST properties of several excipients (ascorbic acid, sucrose, N-acetyl-d-glucosamine, meglumine and 2-pyrrolidone) and tested them as tumor-detecting agents in two different murine tumor models (breast and melanoma cancers). All the investigated molecules showed remarkable CEST contrast upon i.v. administration in the range 1-3ppm according to the type of mobile proton groups. A marked increase of CEST contrast was observed in tumor regions up to 30min post injection. The combination of marked tumor contrast enhancement and lack of toxicity make these molecules potential candidates for the diagnosis of tumors within the MRI-CEST approach. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Nonlinear Dynamics of a Bubble Contrast Agent Oscillating near an Elastic Wall

    Science.gov (United States)

    Garashchuk, Ivan R.; Sinelshchikov, Dmitry I.; Kudryashov, Nikolay A.

    2018-05-01

    Contrast agent microbubbles, which are encapsulated gas bubbles, are widely used to enhance ultrasound imaging. There are also several new promising applications of the contrast agents such as targeted drug delivery and noninvasive therapy. Here we study three models of the microbubble dynamics: a nonencapsulated bubble oscillating close to an elastic wall, a simple coated bubble and a coated bubble near an elastic wall.We demonstrate that complex dynamics can occur in these models. We are particularly interested in the multistability phenomenon of bubble dynamics. We show that coexisting attractors appear in all of these models, but for higher acoustic pressures for the models of an encapsulated bubble.We demonstrate how several tools can be used to localize the coexisting attractors. We provide some considerations why the multistability can be undesirable for applications.

  12. Myocardial Contrast Agents – Safety Considerations and Clinical Efficacy in Stress Echocardiography

    Directory of Open Access Journals (Sweden)

    Maier Anca

    2016-11-01

    Full Text Available Transthoracic echocardiographic examination is known to be a safe, non-invasive and reproducible method, used in every day clinical practice to obtain important information about cardiac structure and function. Unfortunately, a significant proportion of studies have highlighted the considerable technically difficultly in producing diagnostic images due to a poor acoustic window and more than 33% of patients undergoing stress echocardiography have suboptimal echocardiographic images. All these limitations have led to the use of contrast agents to improve the quality of standard ultrasound examination to provide a better delineation of left ventricle endocardial borders or to obtain information that cannot be achieved by using standard echocardiography, such as assessing myocardial microcirculation and therefore perfusion. This paper sought to review the clinical efficacy and safety of ultrasound contrast agents focusing on stress echocardiography.

  13. Dynamic contrast-enhanced MRI using a macromolecular MR contrast agent (P792): Evaluation of antivascular drug effect in a rabbit VX2 liver tumor model

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Sun [Dept. of Radiology, Konkuk University School of Medicine, Seoul (Korea, Republic of); Han, Joon Koo; Lee, Jeong Min; Woo, Sung Min; Choi, Byung Ihn [Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Young Il [Dept. of Radiology, Sheikh Khalifa Specialty Hospital, Ras Al Khaimah (United Arab Emirates); Choi, Jin Young [Dept. of Radiology, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-10-15

    To evaluate the utility of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using macromolecular contrast agent (P792) for assessment of vascular disrupting drug effect in rabbit VX2 liver tumor models. This study was approved by our Institutional Animal Care and Use Committee. DCE-MRI was performed with 3-T scanner in 13 VX2 liver tumor-bearing rabbits, before, 4 hours after, and 24 hours after administration of vascular disrupting agent (VDA), using gadomelitol (P792, n = 7) or low molecular weight contrast agent (gadoterate meglumine [Gd-DOTA], n = 6). P792 was injected at a of dose 0.05 mmol/kg, while that of Gd-DOTA was 0.2 mmol/kg. DCE-MRI parameters including volume transfer coefficient (Ktrans) and initial area under the gadolinium concentration-time curve until 60 seconds (iAUC) of tumors were compared between the 2 groups at each time point. DCE-MRI parameters were correlated with tumor histopathology. Reproducibility in measurement of DCE-MRI parameters and image quality of source MR were compared between groups. P792 group showed a more prominent decrease in Ktrans and iAUC at 4 hours and 24 hours, as compared to the Gd-DOTA group. Changes in DCE-MRI parameters showed a weak correlation with histologic parameters (necrotic fraction and microvessel density) in both groups. Reproducibility of DCE-MRI parameters and overall image quality was not significantly better in the P792 group, as compared to the Gd-DOTA group. Dynamic contrast-enhanced magnetic resonance imaging using a macromolecular contrast agent shows changes of hepatic perfusion more clearly after administration of the VDA. Gadolinium was required at smaller doses than a low molecular contrast agent.

  14. Dynamic contrast-enhanced MRI using a macromolecular MR contrast agent (P792): Evaluation of antivascular drug effect in a rabbit VX2 liver tumor model

    International Nuclear Information System (INIS)

    Park, Hee Sun; Han, Joon Koo; Lee, Jeong Min; Woo, Sung Min; Choi, Byung Ihn; Kim, Young Il; Choi, Jin Young

    2015-01-01

    To evaluate the utility of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using macromolecular contrast agent (P792) for assessment of vascular disrupting drug effect in rabbit VX2 liver tumor models. This study was approved by our Institutional Animal Care and Use Committee. DCE-MRI was performed with 3-T scanner in 13 VX2 liver tumor-bearing rabbits, before, 4 hours after, and 24 hours after administration of vascular disrupting agent (VDA), using gadomelitol (P792, n = 7) or low molecular weight contrast agent (gadoterate meglumine [Gd-DOTA], n = 6). P792 was injected at a of dose 0.05 mmol/kg, while that of Gd-DOTA was 0.2 mmol/kg. DCE-MRI parameters including volume transfer coefficient (Ktrans) and initial area under the gadolinium concentration-time curve until 60 seconds (iAUC) of tumors were compared between the 2 groups at each time point. DCE-MRI parameters were correlated with tumor histopathology. Reproducibility in measurement of DCE-MRI parameters and image quality of source MR were compared between groups. P792 group showed a more prominent decrease in Ktrans and iAUC at 4 hours and 24 hours, as compared to the Gd-DOTA group. Changes in DCE-MRI parameters showed a weak correlation with histologic parameters (necrotic fraction and microvessel density) in both groups. Reproducibility of DCE-MRI parameters and overall image quality was not significantly better in the P792 group, as compared to the Gd-DOTA group. Dynamic contrast-enhanced magnetic resonance imaging using a macromolecular contrast agent shows changes of hepatic perfusion more clearly after administration of the VDA. Gadolinium was required at smaller doses than a low molecular contrast agent

  15. Contrast media and glomerular filtration: dose dependence of clearance for three agents

    International Nuclear Information System (INIS)

    Baeck, S.E.K.; Krutzen, E.; Nilsson-Ehle, P.

    1988-01-01

    Determination of plasma clearance of contrast agents has been advocated as a means to assess glomerular filtration rate. To evaluate the feasibility of different agents for this purpose, we have compared, in healthy volunteers, the dose dependence of plasma clearance for three contrast media (iohexol, a nonionic agent, and iothalamate and metrizoate, which are ionic substances), with special emphasis on the lower dose range (2-20 mL corresponding to 0.9-12.9 g, depending on dose and agent). Iohexol and iothalamate were cleared at constant rates, irrespective of given dose, whereas metrizoate clearance increased significantly at lower doses. In general, the clearances or iothalamate and metrizoate were, respectively, moderately and markedly higher than that of iohexol. The clearance of different doses of metrizoate (2 mL versus a radiographic dose of 40 mL or more) was also compared with the clearance of [ 51 Cr]EDTA in two groups of patients with reduced renal function. When compared with [ 51 Cr]EDTA in patients with renal dysfunction, metrizoate was cleared significantly faster after a 2-mL dose, whereas clearances were identical when the metrizoate dose was 40 mL or more. These findings indicate that tubular secretion plays an active role in the elimination of metrizoate. The pharmacokinetic properties of iohexol, in combination with its low toxicity, make it a suitable agent for determination of glomerular filtration rate in clinical practice

  16. Targeted nanodiamonds as phenotype-specific photoacoustic contrast agents for breast cancer.

    Science.gov (United States)

    Zhang, Ti; Cui, Huizhong; Fang, Chia-Yi; Cheng, Kun; Yang, Xinmai; Chang, Huan-Cheng; Forrest, M Laird

    2015-03-01

    The aim is to develop irradiated nanodiamonds (INDs) as a molecularly targeted contrast agent for high-resolution and phenotype-specific detection of breast cancer with photoacoustic (PA) imaging. The surface of acid treated radiation-damaged nanodiamonds was grafted with PEG to improve its stability and circulation time in blood, followed by conjugation to an anti-HER2 peptide with a final nanoparticle size of approximately 92 nm. Immunocompetent mice bearing orthotopic HER2-positive or negative tumors were administered INDs and PA imaged using an 820-nm near-infrared laser. PA images demonstrated that INDs accumulate in tumors and completely delineated the entire tumor within 10 h. HER2 targeting significantly enhanced imaging of HER2-positive tumors. Pathological examination demonstrated INDs are nontoxic. PA technology is adaptable to low-cost bedside medicine, and with new contrast agents described herein, PA can achieve high-resolution (sub-mm) and phenotype-specific monitoring of cancer growth.

  17. Effects of iodinated contrast agent, xylocaine and gadolinium concentration on the signal emitted in magnetic resonance arthrography: a samples study

    Directory of Open Access Journals (Sweden)

    Yvana Lopes Pinheiro da Silva

    2015-04-01

    Full Text Available Objective: To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality. Materials and Methods: Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration. Results: As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions. Conclusion: Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography.

  18. Follow Up for Emergency Department Patients After Intravenous Contrast and Risk of Nephropathy

    Directory of Open Access Journals (Sweden)

    Getaw Worku Hassen

    2014-05-01

    Full Text Available Introduction: Contrast-induced nephropathy (CIN, defined as an increase in serum creatinine (SCr greater than 25% or ≥0.5 mg/dL within 3 days of intravenous (IV contrast administration in the absence of an alternative cause, is the third most common cause of new acute renal failure in hospitalized patients. It is known to increase in-hospital mortality up to 27%. The purpose of this study was to investigate the rate of outpatient follow up and the occurrence of CIN in patients who presented to the emergency department (ED and were discharged home after computed tomography (CT of the abdomen and pelvis (AP with IV contrast. Methods: We conducted a single center retrospective review of charts for patients who required CT of AP with IV contrast and who were discharged home. Patients’ clinical data included the presence of diabetes mellitus, hypertension, chronic kidney disease (CKD and congestive heart failure (CHF. Results: Five hundred and thirty six patients underwent CT of AP with IV contrast in 2011 and were discharged home. Diabetes mellitus was documented in 96 patients (18%. Hypertension was present in 141 patients (26.3%, and 82 patients (15.3% were on angiotensin-converting-enzyme inhibitors (ACEI. Five patients (0.9% had documented CHF and all of them were taking furosemide. Seventy patients (13% had a baseline SCr >1.2 mg/dL. One hundred fifty patients (28% followed up in one of the clinics or the ED within one week after discharge, but only 40 patients (7.5% had laboratory workup. Out of 40 patients who followed up within 1 week after discharge, 9 patients (22.5% developed CIN. One hundred ninety patients (35.4% followed up in one of the clinics or the ED after 7 days and within 1 month after discharge, but only 71 patients (13.2% had laboratory workup completed. Out of 71 patients who followed up within 1 month, 11 patients (15% developed CIN. The overall incidence of CIN was 15.3% (17 out of 111 patients. Conclusion: There was a

  19. Preventive effect of pretreatment with intravenous nicorandil on contrast-induced nephropathy in patients with renal dysfunction undergoing coronary angiography (PRINCIPLE Study).

    Science.gov (United States)

    Ko, Young-Guk; Lee, Byoung-Kwon; Kang, Woong Chol; Moon, Jae-Youn; Cho, Yun Hyeong; Choi, Seong Hun; Hong, Myeong-Ki; Jang, Yangsoo; Kim, Jong-Youn; Min, Pil-Ki; Kwon, Hyuck-Moon

    2013-07-01

    To investigate the effect of pretreatment with intravenous nicorandil on the incidence of contrast-induced nephropathy (CIN) in patients with renal dysfunction undergoing coronary angiography. This randomized controlled multicenter study enrolled a total of 166 patients (nicorandil n=81; control n=85) with an estimated glomerular filtration rate 0.5 mg/dL increase or >25% rise in serum creatinine (SCr) concentration within 48 hours of contrast exposure compared to baseline. The final analysis included 149 patients (nicorandil n=73; control n=76). The baseline characteristics and the total volume of the used contrast (Iodixanol, 125.6±69.1 mL vs. 126.9±74.6 mL, p=0.916) were similar between the two groups. The incidence of CIN also did not differ between the nicorandil and control groups (6.8% vs. 6.6%, p=0.794). There was no difference between the two groups in the relative change in SCr from baseline to peak level within 48 hours after coronary angiography (-1.58±24.07% vs. 0.96±17.49%, p=0.464), although the nicorandil group showed less absolute change in SCr than the control group (-0.01±0.43 mg/mL vs. 0.02±0.31 mg/mL, p=0.005). Prophylactic intravenous infusion of nicorandil did not decrease the incidence of CIN in patients with renal dysfunction undergoing coronary angiography.

  20. Characterization of D-maltose as a T2 -exchange contrast agent for dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Goldenberg, Joshua M; Pagel, Mark D; Cárdenas-Rodríguez, Julio

    2018-09-01

    We sought to investigate the potential of D-maltose, D-sorbitol, and D-mannitol as T 2 exchange magnetic resonance imaging (MRI) contrast agents. We also sought to compare the in vivo pharmacokinetics of D-maltose with D-glucose with dynamic contrast enhancement (DCE) MRI. T 1 and T 2 relaxation time constants of the saccharides were measured using eight pH values and nine concentrations. The effect of echo spacing in a multiecho acquisition sequence used for the T 2 measurement was evaluated for all samples. Finally, performances of D-maltose and D-glucose during T 2 -weighted DCE-MRI were compared in vivo. Estimated T 2 relaxivities (r 2 ) of D-glucose and D-maltose were highly and nonlinearly dependent on pH and echo spacing, reaching their maximum at pH = 7.0 (∼0.08 mM -1 s -1 ). The r 2 values of D-sorbitol and D-mannitol were estimated to be ∼0.02 mM -1 s -1 and were invariant to pH and echo spacing for pH ≤7.0. The change in T 2 in tumor and muscle tissues remained constant after administration of D-maltose, whereas the change in T 2 decreased in tumor and muscle after administration of D-glucose. Therefore, D-maltose has a longer time window for T 2 -weighted DCE-MRI in tumors. We have demonstrated that D-maltose can be used as a T 2 exchange MRI contrast agent. The larger, sustained T 2 -weighted contrast from D-maltose relative to D-glucose has practical advantages for tumor diagnoses during T 2 -weighted DCE-MRI. Magn Reson Med 80:1158-1164, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  1. Dynamic magnetic resonance angiography of the arteries of the hand. A comparison between an extracellular and an intravascular contrast agent

    International Nuclear Information System (INIS)

    Reisinger, Clemens; Gluecker, Thomas; Jacob, Augustinus Ludwig; Bongartz, Georg; Bilecen, Deniz

    2009-01-01

    The purpose of this study was to compare the image quality of the intravascular contrast agent gadofosveset with the extracellular contrast agent gadoterate meglumine in time-resolved three-dimensional magnetic resonance (MR) angiography of the human arteries of the hand. The value of cuff compression technique for suppression of venous enhancement for both contrast agents was also investigated. Three-dimensional MR angiograms of both hands of 11 healthy volunteers were acquired for each contrast agent at 1.5-T, while subsystolic cuff compression was applied at one side. Quantitative and qualitative evaluation were performed and analyzed with Student's t-test. Visualization of vessels was superior in the images acquired with gadofosveset, especially in the late phases. Quantitative and qualitative evaluation showed significantly higher values for gadofosveset. The cuff compression at the lower arm proved to be an effective method to enhance arterial vessels. In conclusion the blood pool agent gadofosveset is superior for the dynamic imaging of the vessels of the hand when compared with the extracellular contrast agent gadoterate meglumine. To fully utilize the advantages of intravascular contrast agents, venous overlay has to be delayed or reduced, which can be achieved effectively by subsystolic lower arm cuff compression. (orig.)

  2. Clinical use of intravenous gadolinium-DTPA in magnetic resonance imaging of the central nervous system

    International Nuclear Information System (INIS)

    Bydder, G.M.; Niendorf, H.P.; Young, I.R.

    1987-01-01

    Following extensive pharmacological and animal studies clinical trials with intravenous gadolinium-DTPA (Gd-DTPA) were begun at the end of 1983. During 1984 one group in Berlin and another in London conducted clinical trials. During 1985 Gd-DTPA was released more widely and now over 20 groups in Europe and four in the United States are involved in clinical evaluation programmes. Gd-DTPA is the first parenteral magnetic contrast agent available for clinical use and the results of these clinical trials have been followed with considerable interest. In general terms the clinical results with Gd-DTPA parallel those seen with iodinated contrast agents used in X-ray computed tomography (CT) but there are important differences, particularly in relation to the use of pulse sequences and effects due to increased concentration of Gd-DTPA. In this chapter the mode of action of Gd-DTPA is reviewed and the clinical results in the central nervous system are summarised

  3. Pediatric Patients Demonstrate Progressive T1-Weighted Hyperintensity in the Dentate Nucleus following Multiple Doses of Gadolinium-Based Contrast Agent.

    Science.gov (United States)

    Roberts, D R; Chatterjee, A R; Yazdani, M; Marebwa, B; Brown, T; Collins, H; Bolles, G; Jenrette, J M; Nietert, P J; Zhu, X

    2016-12-01

    While there have been recent reports of brain retention of gadolinium following gadolinium-based contrast agent administration in adults, a retrospective series of pediatric patients has not previously been reported, to our knowledge. We investigated the relationship between the number of prior gadolinium-based contrast agent doses and increasing T1 signal in the dentate nucleus on unenhanced T1-weighted MR imaging. We hypothesized that despite differences in pediatric physiology and the smaller gadolinium-based contrast agent doses that pediatric patients are typically administered based on weighted-adjusted dosing, the pediatric brain would also demonstrate dose-dependent increasing T1 signal in the dentate nucleus. We included children with multiple gadolinium-based contrast agent administrations at our institution. A blinded reader placed ROIs within the dentate nucleus and adjacent cerebellar white matter. To eliminate reader bias, we also performed automated ROI delineation of the dentate nucleus, cerebellar white matter, and pons. Dentate-to-cerebellar white matter and dentate-to pons ratios were compared with the number of gadolinium-based contrast agent administrations. During 20 years at our institution, 280 patients received at least 5 gadolinium-based contrast agent doses, with 1 patient receiving 38 doses. Sixteen patients met the inclusion/exclusion criteria for ROI analysis. Blinded reader dentate-to-cerebellar white matter ratios were significantly associated with gadolinium-based contrast agent doses (r s = 0.77, P = .001). The dentate-to-pons ratio and dentate-to-cerebellar white matter ratios based on automated ROI placement were also significantly correlated with gadolinium-based contrast agent doses (t = 4.98, P contrast agent doses is significantly correlated with progressive T1-weighted dentate hyperintensity. Definitive confirmation of gadolinium deposition requires tissue analysis. Any potential clinical sequelae of gadolinium retention in

  4. Effect of MR contrast agents on quantitative accuracy of PET in combined whole-body PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lois, Cristina [University of Santiago de Compostela, Department of Particle Physics, Santiago de Compostela (Spain); Health Research Institute of Santiago de Compostela (IDIS), Santiago de Compostela (Spain); Imaging Science Institute, Tuebingen (Germany); Bezrukov, Ilja [Eberhard Karls University, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens Foundation, Department of Preclinical Imaging and Radiopharmacy, Tuebingen (Germany); Max Plank Institute for Intelligent Systems, Department of Empirical Inference, Tuebingen (Germany); Schmidt, Holger [Eberhard Karls University, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens Foundation, Department of Preclinical Imaging and Radiopharmacy, Tuebingen (Germany); Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Schwenzer, Nina; Werner, Matthias K. [Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Kupferschlaeger, Juergen [Eberhard Karls University, Nuclear Medicine, Department of Radiology, Tuebingen (Germany); Beyer, Thomas [Imaging Science Institute, Tuebingen (Germany); cmi-experts GmbH, Zuerich (Switzerland)

    2012-11-15

    Clinical PET/MR acquisition protocols entail the use of MR contrast agents (MRCA) that could potentially affect PET quantification following MR-based attenuation correction (AC). We assessed the effect of oral and intravenous (IV) MRCA on PET quantification in PET/MR imaging. We employed two MRCA: Lumirem {sup registered} (oral) and Gadovist {sup registered} (IV). First, we determined their reference PET attenuation values using a PET transmission scan (ECAT-EXACT HR+, Siemens) and a CT scan (PET/CT Biograph 16 HI-REZ, Siemens). Second, we evaluated the attenuation of PET signals in the presence of MRCA. Phantoms were filled with clinically relevant concentrations of MRCA in a background of water and {sup 18}F-fluoride, and imaged using a PET/CT scanner (Biograph 16 HI-REZ, Siemens) and a PET/MR scanner (Biograph mMR, Siemens). Third, we investigated the effect of clinically relevant volumes of MRCA on MR-based AC using human pilot data: a patient study employing Gadovist {sup registered} (IV) and a volunteer study employing two different oral MRCA (Lumirem {sup registered} and pineapple juice). MR-based attenuation maps were calculated following Dixon-based fat-water segmentation and an external atlas-based and pattern recognition (AT and PR) algorithm. IV and oral MRCA in clinically relevant concentrations were found to have PET attenuation values similar to those of water. The phantom experiments showed that under clinical conditions IV and oral MRCA did not yield additional attenuation of PET emission signals. Patient scans showed that PET attenuation maps are not biased after the administration of IV MRCA but may be biased, however, after ingestion of iron oxide-based oral MRCA when segmentation-based AC algorithms are used. Alternative AC algorithms, such as AT and PR, or alternative oral contrast agents, such as pineapple juice, can yield unbiased attenuation maps. In clinical PET/MR scenarios MRCA are not expected to lead to markedly increased attenuation

  5. Impact of contrast agent viscosity on coronary balloon deflation times: bench testing results.

    Science.gov (United States)

    Mogabgab, Owen; Patel, Vishal G; Michael, Tesfaldet T; Kotsia, Anna; Christopoulos, George; Banerjee, Subhash; Brilakis, Emmanouil S

    2014-04-01

    To assess the impact of viscosity on angioplasty balloon deflation times. Lower contrast viscosity could result in more rapid coronary balloon deflation times. We performed a bench comparison of coronary balloon deflation times using 2 contrast agents with different viscosity (ioxaglate and iodixanol), 3 contrast dilutions, and 2 inflation syringe filling volumes. Ten identical pairs of coronary angioplasty balloons were used to conduct each comparison after balloon inflation to 12 atmospheres. Simultaneous deflations were performed under cineangiography. The time to full contrast extraction and the area of contrast remaining after 5 seconds of deflation (quantified by opaque pixel count) were compared between groups. The mean time to full contrast extraction during balloon deflation was 8.3 ± 2.5 seconds for ioxaglate (lower viscosity) versus 10.1 ± 2.9 seconds for iodixanol (higher viscosity) (17.4% decrease, P = 0.005), with a 35.6% (P = 0.004) reduction in contrast area at 5 seconds. Compared to 1:1 ioxaglate-saline mixture, 1:2 and 1:3 ioxaglate/saline mixes resulted in 26.7% (P deflation time, respectively, but at the expense of decreased balloon opacity. Filling the inflation syringe with 5 versus 15 ml of contrast/saline solution was associated with 7.5% decrease in balloon deflation time (P = 0.005), but no difference in contrast area at 5 seconds (P = 0.749). Use of a lower viscosity contrast agent and higher contrast dilution significantly reduced coronary balloon deflation times, whereas use of lower syringe filling volume had a modest effect. Rapid coronary balloon deflation could improve the safety of interventional procedures. © 2014 Wiley Periodicals, Inc.

  6. Intravenous contrast medium application in elderly patients - evaluation of Iopentol (Imagopaque trademark 300); Intravenoese Kontrastmittel-Applikation bei aelteren Patienten - Anwendungsbeobachtung von Iopentol (Imagopaque trademark 300)

    Energy Technology Data Exchange (ETDEWEB)

    Rathsmann, P.; Jacobs, G.F.; Mueller, R.D. [Zentrum fuer Klinische Radiologie, Kliniken Essen-Sued (Germany)

    2004-12-01

    Purpose: We examined the subjective compatibility of elderly patients who received the intravenous contrast medium Iopentol (Imagopaque trademark 300). In addition, objective data were acquired to show possible interactions between contrast media and organ systems in old patients. Methods and materials: A CT scan with intravenous application of contrast media was performed on 132 patients ranging in age from 75 to 96 years. The patients were questioned about their individual sensations. In addition, blood pressure, creatinine and CT-densitometry were acquired as objective date. Results: The patients' individual sensations and clinical data show a very low rate of complications. Mild allergic reactions were noticed in two patients. No severe anaphylactic reactions were encountered. Statistically significant changes in blood pressure before and after administration of the contrast medium were not observed. The serum creatinine concentration was unchanged after application of contrast media. For CT-densitometry, the patients were divided into two groups, one group with patients 75-84 years and the other group with patients 85-96 years of age. CT-densitometry showed no age-related differences. The protocol of contrast administration resulted in excellent opacification of the examined regions, only the liver did not enhance in some cases before the opacification of the portal vein. Conclusion: It is shown that old age alone is no reason to withhold contrast media containing iodine when performing CT. For the evaluation of the liver, however, the peculiarities of old age have to be taken into account and the interval between injection of the contrast medium and beginning of the spiral-CT has to be extended. (orig.)

  7. Persistent renal enhancement after intra-arterial versus intravenous iodixanol administration

    International Nuclear Information System (INIS)

    Chou, Shinn-Huey; Wang, Zhen J.; Kuo, Jonathan; Cabarrus, Miguel; Fu Yanjun; Aslam, Rizwan; Yee, Judy; Zimmet, Jeffrey M.; Shunk, Kendrick; Elicker, Brett; Yeh, Benjamin M.

    2011-01-01

    Purpose: To examine the clinical significance of persistent renal enhancement after iodixanol administration. Methods: We retrospectively studied 166 consecutive patients who underwent non-enhanced abdominopelvic CT within 7 days after receiving intra-arterial (n = 99) or intravenous (n = 67) iodixanol. Renal attenuation was measured for each non-enhanced CT scan. Persistent renal enhancement was defined as CT attenuation >55 Hounsfield units (HU). Contrast-induced nephropathy (CIN) was defined as a rise in serum creatinine >0.5 mg/dL within 5 days after contrast administration. Results: While the intensity and frequency of persistent renal enhancement was higher after intra-arterial (mean CT attenuation of 73.7 HU, seen in 54 of 99 patients, or 55%) than intravenous contrast material administration (51.8 HU, seen in 21 of 67, or 31%, p < 0.005), a multivariate regression model showed that the independent predictors of persistent renal enhancement were a shorter time interval until the subsequent non-enhanced CT (p < 0.001); higher contrast dose (p < 0.001); higher baseline serum creatinine (p < 0.01); and older age (p < 0.05). The route of contrast administration was not a predictor of persistent renal enhancement in this model. Contrast-induced nephropathy was noted in 9 patients who received intra-arterial (9%) versus 3 who received intravenous iodixanol (4%), and was more common in patients with persistent renal enhancement (p < 0.01). Conclusion: Persistent renal enhancement at follow-up non-contrast CT suggests a greater risk for contrast-induced nephropathy, but the increased frequency of striking renal enhancement in patients who received intra-arterial rather than intravenous contrast material also reflects the larger doses of contrast and shorter time to subsequent follow-up CT scanning for such patients.

  8. Gadolinium-conjugated PLA-PEG nanoparticles as liver targeted molecular MRI contrast agent.

    Science.gov (United States)

    Chen, Zhijin; Yu, Dexin; Liu, Chunxi; Yang, Xiaoyan; Zhang, Na; Ma, Chunhong; Song, Jibin; Lu, Zaijun

    2011-09-01

    A nanoparticle magnetic resonance imaging (MRI) contrast agent targeted to liver was developed by conjugation of gadolinium (Gd) chelate groups onto the biocompatible poly(l-lactide)-block-poly (ethylene glycol) (PLA-PEG) nanoparticles. PLA-PEG conjugated with diethylenetriaminopentaacetic acid (DTPA) was used to formulate PLA-PEG-DTPA nanoparticles by solvent diffusion method, and then Gd was loaded onto the nanoparticles by chelated with the unfolding DTPA on the surface of the PLA-PEG-DTPA nanoparticles. The mean size of the nanoparticles was 265.9 ± 6.7 nm. The relaxivity of the Gd-labeled nanoparticles was measured, and the distribution in vivo was evaluated in rats. Compared with conventional contrast agent (Magnevist), the Gd-labeled PLA-PEG nanoparticles showed significant enhancement both on liver targeting ability and imaging signal intensity. The T(1) and T(2) relaxivities per [Gd] of the Gd-labeled nanoparticles was 18.865 mM(-1) s(-1) and 24.863 mM(-1) s(-1) at 3 T, respectively. In addition, the signal intensity in vivo was stronger comparing with the Gd-DTPA and the T(1) weight time was lasting for 4.5 h. The liver targeting efficiency of the Gd-labeled PLA-PEG nanoparticles in rats was 14.57 comparing with Magnevist injection. Therefore, the Gd-labeled nanoparticles showed the potential as targeting molecular MRI contrast agent for further clinical utilization.

  9. Improved evaluation of antivascular cancer therapy using constrained tracer-kinetic modeling for multi-agent dynamic contrast-enhanced MRI

    NARCIS (Netherlands)

    Hectors, Stefanie; Jacobs, Igor; Lok, Jasper; Peters, Johannes; Bussink, Johan; Hoeben, Freek J. M.; Keizer, Henk; Janssen, Henk M.; Nicolay, Klaas; Schabel, Matthias; Strijkers, Gustav

    2018-01-01

    Dynamic contrast-enhanced MRI (DCE-MRI) is a promising technique for assessing the response of tumor vasculature to anti-vascular therapies. Multi-agent DCE-MRI employs a combination of low and high molecular weight contrast agents, which potentially improves the accuracy of estimation of tumor

  10. A novel MR contrast agent for angiography and perfusion: Hyperpolarized water

    DEFF Research Database (Denmark)

    Lipsø, Hans Kasper Wigh

    , hyperpolarized by dissolution Dynamic Nuclear Polarization (d-DNP), can be applied as an MRI contrast agent for angiography and perfusion. The first part of the project focuses on development of a protocol for production of large samples of hyperpolarized protons in D2O. The samples are polarized and dissolved...

  11. Gadolinium Contrast Agent is of Limited Value for Magnetic Resonance Imaging Assessment of Synovial Hypertrophy in Hemophiliacs

    Energy Technology Data Exchange (ETDEWEB)

    Lundin, B.; Berntorp, E.; Pettersson, H.; Wirestam, R.; Jonsson, K.; Staahlberg, F.; Ljung, R. [Dept. of Radiology, Univ Hospital of Lund, Lund (Sweden)

    2007-07-15

    Purpose: To examine the influence of different doses of gadolinium contrast agent on synovial enhancement, to compare magnetic resonance imaging (MRI) findings of synovial hypertrophy and radiographic joint changes in hemophiliacs, and to investigate the value of gadolinium in MRI assessment of synovial hypertrophy in hemophiliacs using dynamic MRI and MRI scoring. Material and Methods: Twenty-one hemophiliacs on prophylactic factor treatment without recent bleeds were subjected to radiography and gadolinium contrast-enhanced dynamic and static MRI of the knee using a standard dose of 0.1 mmol/kg b.w. gadoteridol. In 17 of the patients, the MRI procedure was repeated after a triple dose of gadoteridol. Results: MRI findings of synovial hypertrophy were significantly correlated with Pettersson radiographic scores. In 19 of the 21 MRI investigated joints, administration of contrast agent did not alter the result of the evaluation of synovial hypertrophy. Conclusion: The optimal time interval for volume assessment of synovial hypertrophy after injection of gadolinium contrast agent is dose dependent. Hemophiliacs without recent bleeds have minor to abundant synovial hypertrophy in joints with pronounced radiographic changes. Dynamic MRI is not useful for evaluating hemophilic arthropathy, and gadolinium contrast agent is not routinely indicated for MRI scoring of joints in hemophiliacs.

  12. Gadolinium Contrast Agent is of Limited Value for Magnetic Resonance Imaging Assessment of Synovial Hypertrophy in Hemophiliacs

    International Nuclear Information System (INIS)

    Lundin, B.; Berntorp, E.; Pettersson, H.; Wirestam, R.; Jonsson, K.; Staahlberg, F.; Ljung, R.

    2007-01-01

    Purpose: To examine the influence of different doses of gadolinium contrast agent on synovial enhancement, to compare magnetic resonance imaging (MRI) findings of synovial hypertrophy and radiographic joint changes in hemophiliacs, and to investigate the value of gadolinium in MRI assessment of synovial hypertrophy in hemophiliacs using dynamic MRI and MRI scoring. Material and Methods: Twenty-one hemophiliacs on prophylactic factor treatment without recent bleeds were subjected to radiography and gadolinium contrast-enhanced dynamic and static MRI of the knee using a standard dose of 0.1 mmol/kg b.w. gadoteridol. In 17 of the patients, the MRI procedure was repeated after a triple dose of gadoteridol. Results: MRI findings of synovial hypertrophy were significantly correlated with Pettersson radiographic scores. In 19 of the 21 MRI investigated joints, administration of contrast agent did not alter the result of the evaluation of synovial hypertrophy. Conclusion: The optimal time interval for volume assessment of synovial hypertrophy after injection of gadolinium contrast agent is dose dependent. Hemophiliacs without recent bleeds have minor to abundant synovial hypertrophy in joints with pronounced radiographic changes. Dynamic MRI is not useful for evaluating hemophilic arthropathy, and gadolinium contrast agent is not routinely indicated for MRI scoring of joints in hemophiliacs

  13. Quinone-fused porphyrins as contrast agents for photoacoustic imaging

    KAUST Repository

    Banala, Srinivas

    2017-06-27

    Photoacoustic (PA) imaging is an emerging non-invasive diagnostic modality with many potential clinical applications in oncology, rheumatology and the cardiovascular field. For this purpose, there is a high demand for exogenous contrast agents with high absorption coefficients in the optical window for tissue imaging, i.e. the near infrared (NIR) range between 680 and 950 nm. We herein report the photoacoustic properties of quinone-fused porphyrins inserted with different transition metals as new highly promising candidates. These dyes exhibit intense NIR absorption, a lack of fluorescence emission, and PA sensitivity in concentrations below 3 nmol mL. In this context, the highest PA signal was obtained with a Zn(ii) inserted dye. Furthermore, this dye was stable in blood serum and free thiol solution and exhibited negligible cell toxicity. Additionally, the Zn(ii) probe could be detected with an up to 3.2 fold higher PA intensity compared to the clinically most commonly used PA agent, ICG. Thus, further exploration of the \\'quinone-fusing\\' approach to other chromophores may be an efficient way to generate highly potent PA agents that do not fluoresce and shift their absorption into the NIR range.

  14. Development of Gd(III) porphyrin-conjugated chitosan nanoparticles as contrast agents for magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jahanbin, Tania [Université Paul Sabatier, Toulouse III, INSERM U825, CHU Purpan, 31059 Toulouse Cedex 9 (France); Sauriat-Dorizon, Hélène [Institut de Chimie Moléculaire et des Matériaux d' Orsay, UMR CNRS 8182, ECBB, Université Paris-Sud, 91405 Orsay (France); Spearman, Peter [Faculty of Science, Engineering and Computing, University of Kingston, Penrhyn Road Kingston upon Thames Surrey KT1 2EE, London (United Kingdom); Benderbous, Soraya, E-mail: soraya.benderbous@univ-tlse3.fr [Université Paul Sabatier, Toulouse III, INSERM U825, CHU Purpan, 31059 Toulouse Cedex 9 (France); Korri-Youssoufi, Hafsa, E-mail: hafsa.korri-youssoufi@u-psud.fr [Institut de Chimie Moléculaire et des Matériaux d' Orsay, UMR CNRS 8182, ECBB, Université Paris-Sud, 91405 Orsay (France)

    2015-07-01

    A novel magnetic resonance imaging (MRI) contrast agent based on gadolinium meso-tetrakis(4-pyridyl)porphyrin [Gd(TPyP)] conjugated with chitosan nanoparticles has been developed. The chitosan nanoparticles were synthesized following an ionic gelation method and the conditions optimized to generate small nanoparticles (CNs) with a narrow size distribution of 35–65 nm. The gadolinium meso-tetrakis(4-pyridyl)porphyrin [Gd(TPyP)] was loaded into chitosan nanoparticles by passive adsorption. The interaction of chitosan with Gd(TPyP) has been examined by UV–visible, Fourier transform infrared spectroscopies (FT-IR) and inductively coupled plasma mass spectrometry (ICP-MS), which indicate the successful association of Gd(TPyP) without any structural distortion throughout the chitosan nanoparticles. The potential of Gd(TPyP)-CNs as MRI contrast agent has been investigated by magnetic resonance imaging (MRI) in-vitro. Relaxivities of Gd(TPyP)-CNs obtained from T{sub 1}-weighted images, increased with Gd concentration and attained an optimum r{sub 1} of 38.35 mM{sup −1} s{sup −1}, which is 12-fold higher compared to commercial Gd-DOTA (~ 4 mM{sup −1} s{sup −1} at 3T). The combination of such strong MRI contrast with the known properties of porphyrins in photodynamic therapy and biocompatibility of chitosan, presents a new perspective in using these compounds in cancer theranostics. - Highlights: • Synthesis of chitosan nanoparticles with small size • Study of loading properties with gadolinium porphyrins • In vitro properties of the conjugated complex as contrast agent for MRI imaging • Comparison of MRI properties with commercial contrast agent Gd-DOTA.

  15. A novel nitroreductase-enhanced MRI contrast agent and its potential application in bacterial imaging

    Directory of Open Access Journals (Sweden)

    Yun Liu

    2018-05-01

    Full Text Available Nitroreductases (NTRs are known to be able to metabolize nitro-substituted compounds in the presence of reduced nicotinamide adenine dinucleotide (NADH as an electron donor. NTRs are present in a wide range of bacterial genera and, to a lesser extent, in eukaryotes hypoxic tumour cells and tumorous tissues, which makes it an appropriate biomarker for an imaging target to detect the hypoxic status of cancer cells and potential bacterial infections. To evaluate the specific activation level of NTR, great efforts have been devoted to the development of fluorescent probes to detect NTR activities using fluorogenic methods to probe its behaviour in a cellular context; however, NTR-responsive MRI contrast agents are still by far underexplored. In this study, para-nitrobenzyl substituted T1-weighted magnetic resonance imaging (MRI contrast agent Gd-DOTA-PNB (probe 1 has been designed and explored for the possible detection of NTR. Our experimental results show that probe 1 could serve as an MRI-enhanced contrast agent for monitoring NTR activity. The in vitro response and mechanism of the NTR catalysed reduction of probe 1 have been investigated through LC–MS and MRI. Para-nitrobenzyl substituted probe 1 was catalytically reduced by NTR to the intermediate para-aminobenzyl substituted probe which then underwent a rearrangement elimination reaction to Gd-DOTA, generating the enhanced T1-weighted MR imaging. Further, LC–MS and MRI studies of living Escherichia coli have confirmed the NTR activity detection ability of probe 1 at a cellular level. This method may potentially be used for the diagnosis of bacterial infections. KEY WORDS: Nitroreductase, MRI contrast agent, Smart imaging probes, Bacterial imaging, Bacterial infection

  16. Cost-Effectiveness of Intravenous Proton Pump Inhibitors in High-Risk Bleeders

    Directory of Open Access Journals (Sweden)

    Sander Veldhuyzen van Zanten

    2004-01-01

    Full Text Available There is unequivocal evidence that proton pump inhibitors (PPIs are currently the most effective acid suppressive agents available. Intravenous (IV formulations have been developed, although only IV pantoprazole is available in Canada. In patients presenting with serious upper gastrointestinal (GI bleeding due to duodenal or gastric ulcers, it has always been believed that IV administration of acid-lowering agents would improve clinical outcomes. The reason behind this thinking is twofold. First, there is in vitro evidence that formed clots are more stable at or near neutral pH (1. Second, by administering the agent intravenously, suppression of acid production is achieved much more quickly, thereby promoting more rapid healing of the ulcer and reducing the risk of persistent or recurrent bleeding. Interestingly and surprisingly, however, the data for intravenous H2-blockers have been disappointing (2. This failure to demonstrate clinical benefit has never been fully explained.

  17. Ex Vivo Perfusion-Simulation Measurements of Microbubbles as a Scattering Contrast Agent for Grating-Based X-Ray Dark-Field Imaging.

    Directory of Open Access Journals (Sweden)

    Astrid Velroyen

    Full Text Available The investigation of dedicated contrast agents for x-ray dark-field imaging, which exploits small-angle scattering at microstructures for contrast generation, is of strong interest in analogy to the common clinical use of high-atomic number contrast media in conventional attenuation-based imaging, since dark-field imaging has proven to provide complementary information. Therefore, agents consisting of gas bubbles, as used in ultrasound imaging for example, are of particular interest. In this work, we investigate an experimental contrast agent based on microbubbles consisting of a polyvinyl-alcohol shell with an iron oxide coating, which was originally developed for multimodal imaging and drug delivery. Its performance as a possible contrast medium for small-animal angiography was examined using a mouse carcass to realistically consider attenuating and scattering background signal. Subtraction images of dark field, phase contrast and attenuation were acquired for a concentration series of 100%, 10% and 1.3% to mimic different stages of dilution in the contrast agent in the blood vessel system. The images were compared to the gold-standard iodine-based contrast agent Solutrast, showing a good contrast improvement by microbubbles in dark-field imaging. This study proves the feasibility of microbubble-based dark-field contrast-enhancement in presence of scattering and attenuating mouse body structures like bone and fur. Therefore, it suggests a strong potential of the use of polymer-based microbubbles for small-animal dark-field angiography.

  18. Applications of contrast enhanced CT through external jugular access

    International Nuclear Information System (INIS)

    Xu Qiaolan; Zou Wenxing; Chen Meixia; Xie Hongbo

    2005-01-01

    Objective: A retrospective analysis and evaluation for the effects of contrast enhanced computed tomography through external jugular access. Methods: 1250 cases (male 692 and female 558) underwent CT contrast enhanced examination were retrospectively reviewed from May, 2002 to Oct, 2002. The patients aged from 12 to 86 years, averagely 49 years. Contrast agent (Ultravist) was given through an intravenous catheter placed in the cubital vein. Precise injection rates were ensured by a power injector (Medrad MCT310, USA). Excellent enhancement was achieved with this protocol in most of the patients, while external jugular access was established in 96 cases because it was unable to setup a cubital venous access. Results: Good enhancement were acquired when 96 cases of contrast agent injected through external jugular vein. And the external jugular access was setup successfully with a single puncture. Conclusion: It is a common occasion when patient undergoing contrast enhanced CT scan is in poor conditions: debility, cachexia, or with complication of chemotherapy or radiation therapy, which often results in invalidity of cabital venous access, and consequently, making bolus injection impossible. The external jugular vein is a large and central blood vessel, which is easy to setup an access. In our experience, an external jugular access should be recommended as a substitution if the cubital venous access is not available. (authors)

  19. Applications of contrast enhanced CT through external jugular access

    Energy Technology Data Exchange (ETDEWEB)

    Qiaolan, Xu; Wenxing, Zou; Meixia, Chen; Hongbo, Xie [The First Affiliated Hospital of Sun Yat-sen University, Guangzhou (China). Dept. of Radiology

    2005-09-15

    Objective: A retrospective analysis and evaluation for the effects of contrast enhanced computed tomography through external jugular access. Methods: 1250 cases (male 692 and female 558) underwent CT contrast enhanced examination were retrospectively reviewed from May, 2002 to Oct, 2002. The patients aged from 12 to 86 years, averagely 49 years. Contrast agent (Ultravist) was given through an intravenous catheter placed in the cubital vein. Precise injection rates were ensured by a power injector (Medrad MCT310, USA). Excellent enhancement was achieved with this protocol in most of the patients, while external jugular access was established in 96 cases because it was unable to setup a cubital venous access. Results: Good enhancement were acquired when 96 cases of contrast agent injected through external jugular vein. And the external jugular access was setup successfully with a single puncture. Conclusion: It is a common occasion when patient undergoing contrast enhanced CT scan is in poor conditions: debility, cachexia, or with complication of chemotherapy or radiation therapy, which often results in invalidity of cabital venous access, and consequently, making bolus injection impossible. The external jugular vein is a large and central blood vessel, which is easy to setup an access. In our experience, an external jugular access should be recommended as a substitution if the cubital venous access is not available. (authors)

  20. Evaluation of date syrup as an oral negative contrast agent for MRCP.

    Science.gov (United States)

    Govindarajan, Arunkumar; Lakshmanan, Prakash Manikka; Sarawagi, Radha; Prabhakaran, Velu

    2014-11-01

    The purpose of this study was to compare the in vitro effects of date syrup with those of other contrast agents by qualitative and quantitative analysis and in vivo evaluation of the use of date syrup to improve the quality of MRCP images. Phantoms containing date syrup, ferumoxsil, pineapple juice, and water were imaged by 1.5-T MRI with T2-weighted and MRCP sequences, and signal-to-noise ratios were calculated. Biochemical analysis of date syrup was performed to find the nature of iron in it, and the iron content was quantified by energy-dispersive x-ray spectroscopy. Sixty patients underwent MRCP before and 30 minutes after ingestion of 100 mL of date syrup. Unenhanced and contrast-enhanced images were scored for gastrointestinal tract signal suppression and visualization of various pancreaticobiliary structures. In vitro evaluation showed that images obtained with date syrup had a signal-to-noise ratio comparable to that of images obtained with ferumoxsil in T2-weighted and MRCP sequences. The iron concentration in date syrup was 2.6 mg/dL, and it was in ferric form. Images obtained after oral contrast administration had statistically significant improvement in gastrointestinal tract signal suppression (p Date syrup can be used as a negative oral contrast agent for gastrointestinal tract signal suppression during MRCP and for improving visualization of various pancreaticobiliary structures.

  1. Prostate-specific membrane antigen targeted protein contrast agents for molecular imaging of prostate cancer by MRI

    Science.gov (United States)

    Pu, Fan; Salarian, Mani; Xue, Shenghui; Qiao, Jingjuan; Feng, Jie; Tan, Shanshan; Patel, Anvi; Li, Xin; Mamouni, Kenza; Hekmatyar, Khan; Zou, Juan; Wu, Daqing; Yang, Jenny J.

    2016-06-01

    Prostate-specific membrane antigen (PSMA) is one of the most specific cell surface markers for prostate cancer diagnosis and targeted treatment. However, achieving molecular imaging using non-invasive MRI with high resolution has yet to be achieved due to the lack of contrast agents with significantly improved relaxivity for sensitivity, targeting capabilities and metal selectivity. We have previously reported our creation of a novel class of protein Gd3+ contrast agents, ProCA32, which displayed significantly improved relaxivity while exhibiting strong Gd3+ binding selectivity over physiological metal ions. In this study, we report our effort in further developing biomarker-targeted protein MRI contrast agents for molecular imaging of PSMA. Among three PSMA targeted contrast agents engineered with addition of different molecular recognition sequences, ProCA32.PSMA exhibits a binding affinity of 1.1 +/- 0.1 μM for PSMA while the metal binding affinity is maintained at 0.9 +/- 0.1 × 10-22 M. In addition, ProCA32.PSMA exhibits r1 of 27.6 mM-1 s-1 and r2 of 37.9 mM-1 s-1 per Gd (55.2 and 75.8 mM-1 s-1 per molecule r1 and r2, respectively) at 1.4 T. At 7 T, ProCA32.PSMA also has r2 of 94.0 mM-1 s-1 per Gd (188.0 mM-1 s-1 per molecule) and r1 of 18.6 mM-1 s-1 per Gd (37.2 mM-1 s-1 per molecule). This contrast capability enables the first MRI enhancement dependent on PSMA expression levels in tumor bearing mice using both T1 and T2-weighted MRI at 7 T. Further development of these PSMA-targeted contrast agents are expected to be used for the precision imaging of prostate cancer at an early stage and to monitor disease progression and staging, as well as determine the effect of therapeutic treatment by non-invasive evaluation of the PSMA level using MRI.Prostate-specific membrane antigen (PSMA) is one of the most specific cell surface markers for prostate cancer diagnosis and targeted treatment. However, achieving molecular imaging using non-invasive MRI with high

  2. Barium sulfate suspension as a negative oral contrast agent for MR imaging

    International Nuclear Information System (INIS)

    Li, K.C.P.; Tart, R.P.; Fitzsimmons, J.R.; Storm, B.; Mao, J.

    1989-01-01

    Proton spectroscopy with linewidth measurements and MR imaging were performed on various commercially available barium sulfate suspensions as well as inorganic sulfates and barium salts. Approximately 500 mL of 20%, 40%, 60%, and 70% wt/wt single-contrast oral barium sulfate suspensions were administered to four normal volunteers, and MR imaging was performed with both a 1.5-T and a 0.15-T MR imager. As much as 80% of the small bowel and the entire colon were well visualized with the 60% or 70% wt/wt single-contrast barium sulfate suspensions. The authors conclude that barium sulfate suspensions are useful as oral MR contrast agents

  3. Characterization of colloidal manganese hydroxylapatite: A potential magnetic resonance contrast agent

    Science.gov (United States)

    Dorshow, Richard B.; Kofi Adzamli, I.; Nosco, Dennis L.; Joslin, Frederick L.

    1996-03-01

    Particulate contrast agents for blood pool imaging need to be constructed with the appropriate particle size distribution (PSD), and need to be resistant to opsonization. Hence, the PSD of an aqueous colloidal suspension of polyethylene glycol (PEG)-stabilized manganese hydroxylapatite (potentially useful as a magnetic resonance contrast agent for blood pool imaging) has been investigated as a function of PEG concentration and molecular weight. At low PEG concentrations, dynamic light scattering (DLS) and sedimentation field flow fractionation measurements yield a broad PSD, with the largest particle diameters near 100nm. Flow field flow fractionation (FlFFF) measurements, however, yield a distinct population near 10nm, which is not readily detectable by the other two techniques. As the PEG concentration is increased, the PSD shifts toward the lower size population. At the highest PEG concentration employed, only particles of diameter 10nm remain, verified by both FlFFF and DLS. Thus, the search for an optimum PSD for blood pool imaging is facilitated by choice of PEG molecular weight and concentration, and by employing complementary use of light scattering and field flow fractionation techniques.

  4. A novel technology: microfluidic devices for microbubble ultrasound contrast agent generation.

    Science.gov (United States)

    Lin, Hangyu; Chen, Junfang; Chen, Chuanpin

    2016-09-01

    Microbubbles are used as ultrasound contrast agents, which enhance ultrasound imaging techniques. In addition, microbubbles currently show promise in disease therapeutics. Microfluidic devices have increased the ability to produce microbubbles with precise size, and high monodispersity compared to microbubbles created using traditional methods. This paper will review several variations in microfluidic device structures used to produce microbubbles as ultrasound contrast agents. Microfluidic device structures include T-junction, and axisymmetric and asymmetric flow-focusing. These devices have made it possible to produce microbubbles that can enter the vascular space; these microbubbles must be less than 10 μm in diameter and have high monodispersity. For different demands of microbubbles production rate, asymmetric flow-focusing devices were divided into individual and integrated devices. In addition, asymmetric flow-focusing devices can produce double layer and multilayer microbubbles loaded with drug or biological components. Details on the mechanisms of both bubble formation and device structures are provided. Finally, microfluidically produced microbubble acoustic responses, microbubble stability, and microbubble use in ultrasound imaging are discussed.

  5. Targeted Nanodiamonds as Phenotype Specific Photoacoustic Contrast Agents for Breast Cancer

    Science.gov (United States)

    Zhang, Ti; Cui, Huizhong; Fang, Chia-Yi; Cheng, Kun; Yang, Xinmai; Chang, Huan-Cheng; Forrest, M. Laird

    2015-01-01

    Aim The aim is to develop irradiated nanodiamonds (INDs) as a molecularly-targeted contrast agent for high resolution and phenotype-specific detection of breast cancer with photoacoustic (PA) imaging. Materials & Methods The surface of acid treated radiation-damaged nanodiamonds was grafted with polyethylene glycol (PEG) to improve its stability and circulation time in blood, followed by conjugation to an anti-Human epidermal growth factor receptor-2 (HER2) peptide (KCCYSL) with a final nanoparticle size of ca. 92 nm. Immunocompetent mice bearing orthotopic HER2 positive or negative tumors were administered INDs and PA imaged using an 820-nm near infrared laser. Results PA images demonstrated that INDs accumulate in tumors and completely delineated the entire tumor within 10 hours. HER2 targeting significantly enhanced imaging of HER2-positive tumors. Pathological examination demonstrated INDs are non-toxic. Conclusions PA technology is adaptable to low-cost bedside medicine, and with new contrast agents described herein, PA can achieve high resolution (sub-mm) and phenotype specific monitoring of cancer growth. PMID:25723091

  6. Fabrication and imaging study of ultrasound/fluorescence bi-modal contrast agent based on polymeric microbubbles

    International Nuclear Information System (INIS)

    Xing Zhanwen; Ke Hengte; Wang Jinrui; Zhao Bo; Qu Enze; Yue Xiuli; Dai Zhifei

    2013-01-01

    Objective: To fabricate an ultrasound/fluorescence bi-modal contrast agent by encapsulating fluorescent quantum dots into polymeric ultrasound contrast agent microbubbles. Methods: Polylactic acid (PLA, 500 mg), (1R)-(+)-camphor (50 mg) and CdSe/ZnS quantum dots (0.5 ml, 2.3 μmol/L)were dissolved or dispersed in dichloromethane (10 ml) to form in an organic phase. Ammonium carbonate solution and poly (vinyl alcohol) solution were employed as the internal and external water phase, respectively. The fluorescent microbubbles were generated using double emulsion solvent evaporation and lyophilization methods. The morphology and illumination were characterized by scanning electron microscopy (SEM) and fluorescence spectrophotometry. Synchronized contrast-enhanced ultrasound and fluorescence imaging was acquired by injecting fluorescent microbubbles into the silicone tube coupled to a self-made ultrasound/fluorescence imaging device. Ultrasound/fluorescence bi-modal in vivo imaging was acquired on the kidney of New Zealand rabbits and suckling mice. Results: The fluorescent microbubbles were hollow spheres with an averaged diameter of (1.62 ± 1.47) μm. More than 99% of these microbubbles were less than 8 μm in diameter, which met the size criteria for ultrasound contrast agents. The fluorescence emission peak of the microbubbles appeared at 632 nm, indicating that good luminescence properties of quantum dots were maintained. In vitro ultrasound/fluorescence imaging showed no echoic signal when the silicone tube was filled with saline, but there was a strong echo when filled with fluorescent microbubbles. The liquid column with fluorescent microbubbles emitted red luminescence under ultraviolet irradiation. The kidney of the rabbit was remarkably enhanced after the administration of fluorescent microbubbles. Bright fluorescence could be observed at the injection site of the suckling mice via subcutaneous injection. Conclusions: A bi-modal but single contrast agent

  7. Synchrotron-based DEI for bio-imaging and DEI-CT to image phantoms with contrast agents

    International Nuclear Information System (INIS)

    Rao, Donepudi V.; Swapna, Medasani; Cesareo, Roberto; Brunetti, Antonio; Akatsuka, Tako; Yuasa, Tetsuya; Zhong, Zhong; Takeda, Tohoru; Gigante, Giovanni E.

    2012-01-01

    The introduction of water, physiological, or iodine as contrast agents is shown to enhance minute image features in synchrotron-based X-ray diffraction radiographic and tomographic imaging. Anatomical features of rat kidney, such as papillary ducts, ureter, renal artery and renal vein are clearly distinguishable. Olfactory bulb, olfactory tact, and descending bundles of the rat brain are visible with improved contrast. - Highlights: ► Distinguishable anatomical structures features of rat kidney and rat brain are acquired with Sy-DEI in planar mode. ► Images of a small brain phantom and cylindrical phantom are acquired in tomography mode (Sy-DEI-CT) with contrast agents. ► Sy-DEI and Sy-DEI-CT techniques provide new source of information related to biological microanatomy.

  8. Diagnosis of Popliteal Venous Entrapment Syndrome by Magnetic Resonance Imaging Using Blood-Pool Contrast Agents

    International Nuclear Information System (INIS)

    Beitzke, Dietrich; Wolf, Florian; Juelg, Gregor; Lammer, Johannes; Loewe, Christian

    2011-01-01

    Popliteal vascular entrapment syndrome is caused by aberrations or hypertrophy of the gastrocnemius muscles, which compress the neurovascular structures of the popliteal fossa, leading to symptoms of vascular and degeneration as well as aneurysm formation. Imaging of popliteal vascular entrapment may be performed with ultrasound, magnetic resonance imaging (MRI), computed tomography angiography, and conventional angiography. The use of blood-pool contrast agents in MRI when popliteal vascular entrapment is suspected offers the possibility to perform vascular imaging with first-pass magnetic resonance angiographic, high-resolution, steady-state imaging and allows functional tests all within one examination with a single dose of contrast agent. We present imaging findings in a case of symptomatic popliteal vein entrapment diagnosed by the use of blood pool contrast-enhanced MRI.

  9. Carbon Nano-Allotrope/Magnetic Nanoparticle Hybrid Nanomaterials as T2 Contrast Agents for Magnetic Resonance Imaging Applications

    Directory of Open Access Journals (Sweden)

    Yunxiang Gao

    2018-02-01

    Full Text Available Magnetic resonance imaging (MRI is the most powerful tool for deep penetration and high-quality 3D imaging of tissues with anatomical details. However, the sensitivity of the MRI technique is not as good as that of the radioactive or optical imaging methods. Carbon-based nanomaterials have attracted significant attention in biomaterial research in recent decades due to their unique physical properties, versatile functionalization chemistry, as well as excellent biological compatibility. Researchers have employed various carbon nano-allotropes to develop hybrid MRI contrast agents for improved sensitivity. This review summarizes the new research progresses in carbon-based hybrid MRI contrast agents, especially those reported in the past five years. The review will only focus on T2-weighted MRI agents and will be categorized by the different carbon allotrope types and magnetic components. Considering the strong trend in recent bio-nanotechnology research towards multifunctional diagnosis and therapy, carbon-based MRI contrast agents integrated with other imaging modalities or therapeutic functions are also covered.

  10. Preclinical evaluation of Gd-DTPA and gadomelitol as contrast agents in DCE-MRI of cervical carcinoma interstitial fluid pressure

    Directory of Open Access Journals (Sweden)

    Hompland Tord

    2012-11-01

    Full Text Available Abstract Background High interstitial fluid pressure (IFP in the primary tumor is associated with poor disease-free survival in locally advanced cervical carcinoma. A noninvasive assay is needed to identify cervical cancer patients with highly elevated tumor IFP because these patients may benefit from particularly aggressive treatment. It has been suggested that dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI with gadolinium diethylene-triamine penta-acetic acid (Gd-DTPA as contrast agent may provide useful information on the IFP of cervical carcinomas. In this preclinical study, we investigated whether DCE-MRI with contrast agents with higher molecular weights (MW than Gd-DTPA would be superior to Gd-DTPA-based DCE-MRI. Methods CK-160 human cervical carcinoma xenografts were subjected to DCE-MRI with Gd-DTPA (MW of 0.55 kDa or gadomelitol (MW of 6.5 kDa as contrast agent before tumor IFP was measured invasively with a Millar SPC 320 catheter. The DCE-MRI was carried out at a spatial resolution of 0.23 × 0.23 × 2.0 mm3 and a time resolution of 14 s by using a 1.5-T whole-body scanner and a slotted tube resonator transceiver coil constructed for mice. Parametric images were derived from the DCE-MRI recordings by using the Tofts iso-directional transport model and the Patlak uni-directional transport model. Results When gadomelitol was used as contrast agent, significant positive correlations were found between the parameters of both pharmacokinetic models and tumor IFP. On the other hand, significant correlations between DCE-MRI-derived parameters and IFP could not be detected with Gd-DTPA as contrast agent. Conclusion Gadomelitol is a superior contrast agent to Gd-DTPA in DCE-MRI of the IFP of CK-160 cervical carcinoma xenografts. Clinical studies attempting to develop DCE-MRI-based assays of the IFP of cervical carcinomas should involve contrast agents with higher MW than Gd-DTPA.

  11. Preclinical evaluation of Gd-DTPA and gadomelitol as contrast agents in DCE-MRI of cervical carcinoma interstitial fluid pressure.

    Science.gov (United States)

    Hompland, Tord; Ellingsen, Christine; Rofstad, Einar K

    2012-11-22

    High interstitial fluid pressure (IFP) in the primary tumor is associated with poor disease-free survival in locally advanced cervical carcinoma. A noninvasive assay is needed to identify cervical cancer patients with highly elevated tumor IFP because these patients may benefit from particularly aggressive treatment. It has been suggested that dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) with gadolinium diethylene-triamine penta-acetic acid (Gd-DTPA) as contrast agent may provide useful information on the IFP of cervical carcinomas. In this preclinical study, we investigated whether DCE-MRI with contrast agents with higher molecular weights (MW) than Gd-DTPA would be superior to Gd-DTPA-based DCE-MRI. CK-160 human cervical carcinoma xenografts were subjected to DCE-MRI with Gd-DTPA (MW of 0.55 kDa) or gadomelitol (MW of 6.5 kDa) as contrast agent before tumor IFP was measured invasively with a Millar SPC 320 catheter. The DCE-MRI was carried out at a spatial resolution of 0.23 × 0.23 × 2.0 mm³ and a time resolution of 14 s by using a 1.5-T whole-body scanner and a slotted tube resonator transceiver coil constructed for mice. Parametric images were derived from the DCE-MRI recordings by using the Tofts iso-directional transport model and the Patlak uni-directional transport model. When gadomelitol was used as contrast agent, significant positive correlations were found between the parameters of both pharmacokinetic models and tumor IFP. On the other hand, significant correlations between DCE-MRI-derived parameters and IFP could not be detected with Gd-DTPA as contrast agent. Gadomelitol is a superior contrast agent to Gd-DTPA in DCE-MRI of the IFP of CK-160 cervical carcinoma xenografts. Clinical studies attempting to develop DCE-MRI-based assays of the IFP of cervical carcinomas should involve contrast agents with higher MW than Gd-DTPA.

  12. Preclinical evaluation of Gd-DTPA and gadomelitol as contrast agents in DCE-MRI of cervical carcinoma interstitial fluid pressure

    International Nuclear Information System (INIS)

    Hompland, Tord; Ellingsen, Christine; Rofstad, Einar K

    2012-01-01

    High interstitial fluid pressure (IFP) in the primary tumor is associated with poor disease-free survival in locally advanced cervical carcinoma. A noninvasive assay is needed to identify cervical cancer patients with highly elevated tumor IFP because these patients may benefit from particularly aggressive treatment. It has been suggested that dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) with gadolinium diethylene-triamine penta-acetic acid (Gd-DTPA) as contrast agent may provide useful information on the IFP of cervical carcinomas. In this preclinical study, we investigated whether DCE-MRI with contrast agents with higher molecular weights (MW) than Gd-DTPA would be superior to Gd-DTPA-based DCE-MRI. CK-160 human cervical carcinoma xenografts were subjected to DCE-MRI with Gd-DTPA (MW of 0.55 kDa) or gadomelitol (MW of 6.5 kDa) as contrast agent before tumor IFP was measured invasively with a Millar SPC 320 catheter. The DCE-MRI was carried out at a spatial resolution of 0.23 × 0.23 × 2.0 mm 3 and a time resolution of 14 s by using a 1.5-T whole-body scanner and a slotted tube resonator transceiver coil constructed for mice. Parametric images were derived from the DCE-MRI recordings by using the Tofts iso-directional transport model and the Patlak uni-directional transport model. When gadomelitol was used as contrast agent, significant positive correlations were found between the parameters of both pharmacokinetic models and tumor IFP. On the other hand, significant correlations between DCE-MRI-derived parameters and IFP could not be detected with Gd-DTPA as contrast agent. Gadomelitol is a superior contrast agent to Gd-DTPA in DCE-MRI of the IFP of CK-160 cervical carcinoma xenografts. Clinical studies attempting to develop DCE-MRI-based assays of the IFP of cervical carcinomas should involve contrast agents with higher MW than Gd-DTPA

  13. The use of contrast agent for imaging biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J; Sopko, V; Jakubek, J [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ 12800 Prague 2 (Czech Republic); Weyda, F, E-mail: jiri.dammer@utef.cvut.cz [Biological center of the Academy of Sciences of the Czech Republic, Institute of Entomology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic)

    2011-01-15

    The technique of X-ray transmission imaging has been available for over a century and is still among the fastest and easiest approaches to the studies of internal structure of biological samples. Recent advances in semiconductor technology have led to the development of new types of X-ray detectors with direct conversion of interacting X-ray photon to an electric signal. Semiconductor pixel detectors seem to be specially promising; compared to the film technique, they provide single-quantum and real-time digital information about the objects being studied. We describe the recently developed radiographic apparatus, equipped with Medipix2 semiconductor pixel detector. The detector is used as an imager that counts individual photons of ionizing radiation, emitted by an X-ray tube (micro- or nano-focus FeinFocus). Thanks to the wide dynamic range of the Medipix2 detector and its high spatial resolution better than 1{mu}m, the setup is particularly suitable for radiographic imaging of small biological samples, including in-vivo observations with contrast agent (Optiray). Along with the description of the apparatus we provide examples of the use iodine contrast agent as a tracer in various insects as model organisms. The motivation of our work is to develop our imaging techniques as non-destructive and non-invasive. Microradiographic imaging helps detect organisms living in a not visible environment, visualize the internal biological processes and also to resolve the details of their body (morphology). Tiny live insects are an ideal object for our studies.

  14. The diagnostic effectiveness of contrast media in the excretory urography in dogs

    International Nuclear Information System (INIS)

    Velesova, M.; Ledecky, V.

    2005-01-01

    A clinical study was conducted to investigate the use of four different positive contrast media, Omnipaque (Nycomed Imaging As.), Optiray (Maliincrodt Medical GmbH), Ultravist (Schering AG), and Urografin (Schering AG) in normograde excretory urography. Investigations were carried out on thirteen dogs. Each group of dogs was administered a different contrast medium. Radiographs were obtained immediately after the administration of contrast media and after a lapse of 5, 10 and 15 minutes. The effectiveness of the application was evaluated by assessing the radiographs of abdominal cavities in ventro-dorsal and latero-lateral positions. None of the dogs showed pronounced side effect after the application of contrast media. Ectopic ureter was diagnosed in three and a prostate cyst in one of the patients. Our results showed that Omnipaque and Ultravist were the contrast agents most suitable for the examination of the urinary apparatus by intravenous contrast excretory urography. Their advantage is that visualisation of the kidneys and ureters achieved by these media are sufficiently long and contrastive

  15. Highly stabilized gadolinium chelates functionalized on metal nanoparticles as magnetic resonance imaging contrast agent

    Science.gov (United States)

    Siddiqui, Talha S.

    Magnetic resonance imaging (MRI) is a non-invasive method for imaging and diagnosing tissue damage, organ function and the vascular system. Magnevist(TM) a complex of diethylenetriaminepentaacetic acid (DTPA) and Gd3+ is a clinically approved contrast agent for MRI. A derivative of DTPA was formed by the addition of two cysteine groups (DTPA-L-Cys) through amide linkage. The Gd complex of this ligand bonds with the silver surfaces through the cysteine thiols. GdDTPA-L-Cys was bound to ˜10nm diameter Ag nanoparticles for use as a multifunctional MRI contrast agent. The ligand and complex were characterized by 1H and 13C NMR, ESI-MS and IR spectroscopy. The silver construct was characterized by TEM, TGA and UV-Vis absorption spectra. The per metal complex r1 relaxivity of GdDTPA-L-Cys{Ag} greater than that of Magnavist(TM) with the same molarity for both compounds. The synthesis of a DTPA derivative is described that allows it to bind to silver or gold nanoparticles through a single thiol linkage (DTPASH). The resulting Gd complex, GdDTPASH, was bound to Ag nanoparticles to create a single monolayer on the surface. The construct was further stabilized in buffered solution with the addition of a thiolated PEG chain. The highly stabilized nanoparticle construct delivers a high payload of Gd compelex and is an effective T1 brightening agent. The production of this type of construct opens the way for engineered multimodal MRI contrast agents.

  16. Quantitative Molecular Imaging with a Single Gd-Based Contrast Agent Reveals Specific Tumor Binding and Retention in Vivo.

    Science.gov (United States)

    Johansen, Mette L; Gao, Ying; Hutnick, Melanie A; Craig, Sonya E L; Pokorski, Jonathan K; Flask, Chris A; Brady-Kalnay, Susann M

    2017-06-06

    Magnetic resonance imaging (MRI) has become an indispensable tool in the diagnosis and treatment of many diseases, especially cancer. However, the poor sensitivity of MRI relative to other imaging modalities, such as PET, has hindered the development and clinical use of molecular MRI contrast agents that could provide vital diagnostic information by specifically locating a molecular target altered in the disease process. This work describes the specific and sustained in vivo binding and retention of a protein tyrosine phosphatase mu (PTPμ)-targeted, molecular magnetic resonance (MR) contrast agent with a single gadolinium (Gd) chelate using a quantitative MRI T 1 mapping technique in glioma xenografts. Quantitative T 1 mapping is an imaging method used to measure the longitudinal relaxation time, the T 1 relaxation time, of protons in a magnetic field after excitation by a radiofrequency pulse. T 1 relaxation times can in turn be used to calculate the concentration of a gadolinium-containing contrast agent in a region of interest, thereby allowing the retention or clearance of an agent to be quantified. In this context, retention is a measure of molecular contrast agent binding. Using conventional peptide chemistry, a PTPμ-targeted peptide was linked to a chelator that had been conjugated to a lysine residue. Following complexation with Gd, this PTPμ-targeted molecular contrast agent containing a single Gd ion showed significant tumor enhancement and a sustained increase in Gd concentration in both heterotopic and orthotopic tumors using dynamic quantitative MRI. This single Gd-containing PTPμ agent was more effective than our previous version with three Gd ions. Differences between nonspecific and specific agents, due to specific tumor binding, can be determined within the first 30 min after agent administration by examining clearance rates. This more facile chemistry, when combined with quantitative MR techniques, allows for widespread adoption by academic

  17. Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study.

    Science.gov (United States)

    Kingston, Mitchell J; Perriman, Diana M; Neeman, Teresa; Smith, Paul N; Webb, Alexandra L

    2016-07-01

    Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four sets of cannulae of known diameter, were injected with one of three different contrast agents (barium sulfate and resin, barium sulfate and gelatin, and lead oxide combined with milk powder). All were then scanned using micro-computed tomography (CT) angiography and 3-D reconstructions generated. The number of branching generations of the rat lower limb vessels were counted and compared between the contrast agents using ANOVA. The diameter of the contrast-filled cannulae, were measured and used to calculate the accuracy of the measurements by comparing the bias and variance of the estimates. Intra- and inter-observer reliability were calculated using intra-class correlation coefficients. There was no significant difference (mean difference [MD] 0.05; MD 95% confidence interval [CI] -0.83 to 0.93) between the number of branching generations for barium sulfate-resin and lead oxide-milk powder. Barium sulfate-resin demonstrated less bias and less variance of the estimates (MD 0.03; standard deviation [SD] 1.96 mm) compared to lead oxide-milk powder (MD 0.11; SD 1.96 mm) for measurements of contrast-filled cannulae scanned at high resolution. Barium sulfate-resin proved to be more accurate than lead oxide-milk powder for high resolution micro-CT scans and is preferred due to its non-toxicity. This technique could be applied to any embalmed specimen model. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Impact of acoustic pressure on ambient pressure estimation using ultrasound contrast agent

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup; Jensen, Jørgen Arendt

    2010-01-01

    Local blood pressure measurements provide important information on the state of health of organs in the body and can be used to diagnose diseases in the heart, lungs, and kidneys. This paper presents an approach for investigating the ambient pressure sensitivity of a contrast agent using diagnostic...

  19. Effects of detomidine on equine oesophageal function as studied by contrast radiography

    International Nuclear Information System (INIS)

    Watson, T.D.G.; Sullivan, M.

    1991-01-01

    The effects of sedation with detomidine on oesophageal function were assessed by contrast radiography in 10 healthy adult thoroughbred horses. Barium swallows were monitored by means of image intensification, first without sedation and then after the intravenous administration of detomidine at doses of 10 and 20 micrograms/kg bodyweight. The transit time of contrast agent to the oesophageal hiatus was recorded and each swallow was scored for markers of oesophageal dysfunction. Analysis of the data indicated that there were highly significant dose dependent increases in the transit time, the retention of barium within the longitudinal mucosal folds, and retrograde peristalsis and pooling of contrast agent within the oesophagus at both the thoracic inlet and caudal to the base of the heart. The degree of gastrooesophageal reflux was not affected at either dosage. These changes in oesophageal function were similar to those recorded from cases of grass sickness and indicate that care should be taken in the interpretation of studies of swallowing in animals that have been given detomidine before a radiographic examination

  20. Delivery of Optical Contrast Agents using Triton-X100, Part 1: Reversible permeabilization of live cells for intracellular labeling

    OpenAIRE

    van de Ven, Anne L; Adler-Storthz, Karen; Richards-Kortum, Rebecca

    2009-01-01

    Effective delivery of optical contrast agents into live cells remains a significant challenge. We sought to determine whether Triton-X100, a detergent commonly used for membrane isolation and protein purification, could be used to effectively and reversibly permeabilize live cells for delivery of targeted optical contrast agents. Although Triton-X100 is widely recognized as a good cell permeabilization agent, no systematic study has evaluated the efficiency, reproducibility, and reversibility...

  1. Balancing stealth and echogenic properties in an ultrasound contrast agent with drug delivery potential.

    Science.gov (United States)

    Jablonowski, Lauren J; Alfego, David; Andorko, James I; Eisenbrey, John R; Teraphongphom, Nutte; Wheatley, Margaret A

    2016-10-01

    Contrast agents are currently being modified to combine diagnostic and therapeutic capabilities. For ultrasound (US) imaging with polymeric contrast agents, it is necessary to modify the shell to create "stealth" microbubbles but without these modifications sacrificing the agent's ability to interact with the focused US beam. We hypothesize that addition of the classic immune shielding molecule polyethylene glycol (PEG) to a polylactide (PLA) microbubble shell will affect the acoustic and physical properties of the resulting agents. In an effort to determine the best formulation to achieve a balance between stealth and acoustic activity, we compared two PEGylation techniques; addition of increasing amounts of PEG-PLA copolymer and employing incorporation of a PEG lipid (LipidPEG) into the shell. Loss of acoustic enhancement occurred in a dose-dependent manner for both types of PEGylated agents (loss of signal occurred at >5 wt% PEG-PLA and >1 wt% LipidPEG), while immune activation was also reduced in a dose-dependent manner for the PEG-PLA agents. This study shows that the balance between acoustic behavior and improved immune avoidance was scalable and successful to different degrees with both PEGylation methods, and was best achieved using for PEG-PLA at 5 wt% and for LipidPEG at 1 wt%. Studies are ongoing to evaluate the best method for the targeting and drug delivery capabilities of these agents for applications in cancer treatment. This study represents the basis for understanding the consequences of making modifications to the native polymeric shell. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Renal effects of the non-ionic contrast medium iopentol after intravenous injection in healthy volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Jakobsen, J.A.; Berg, K.J.; Waaler, A.; Andrew, E. (Rikshospitalet, Oslo (Norway). Dept. of Radiology Rikshospitalet, Oslo (Norway). Renal Section Nycomed A/S, Oslo (Norway). Dept. of Clinical Research and Development)

    1990-01-01

    Renal effects of the new non-ionic contrast medium iopentol in increasing doses were assessed and compared with the effects of physiologic saline. Twenty-four healthy male volunteers, allocated to three dose groups, were given iopentol intravenously in doses of 0.3, 0.6, and 1.2 g I/kg body weight, respectively. The highest dose group was also given physiologic saline separately as a control. The diuresis increased in all groups, most in the highest dose group, and with a concomitant fall of urine osmolality and increase in osmolar clearance. A slight decrease of serum osmolality, creatinine and urea occurred at 3 hours due to hemodilution. The glomerular filtration rate was unaffected by iopentol. The urinary excretion of albumin and {beta}{sub 2}-microglobulin was unchanged. However, urinary N-acetyl-{beta}-glucosaminidase and alkaline phosphatase increased significantly, most in the highest dose group. All changes were reversible. (orig.).

  3. Hysteretic Nonlinearity of Sub-harmonic Emission from Ultrasound Contrast Agent Microbubbles

    International Nuclear Information System (INIS)

    Qiu Yuan-Yuan; Zhang Dong; Zheng Hai-Rong

    2011-01-01

    Sub-harmonic contrast imaging promises to improve ultrasound imaging quality by taking advantage of increased contrast to tissue signal. The aim of this study is to examine the hysteretic nonlinearity of sub-harmonic component emitted from microbubbles. Two kinds of microbubble solutions, i.e. Sonovue® and a self-developed contrast agent, are utilized in the study. The hysteretic curves for increasing and decreasing acoustic pressure are theoretically predicted by the Marmottant model and confirmed by measurements. The results reveal that for both microbubble solutions, the development of the rising ramp undergoes three stages, i.e. occurrence, growth and saturation; while hysteresis effect appears in the descending ramp. Sonovue® microbubbles exhibit better sub-harmonic performance over the self-developed UCAs microbubbles due to the difference of elastic properties of the shell. (fundamental areas of phenomenology(including applications))

  4. Use of iohexol as a gastrointestinal contrast agent in three dogs, five cats, and one bird

    International Nuclear Information System (INIS)

    Williams, J.; Biller, D.S.; Myer, C.W.; Miyabayashi, T.; Leveille, R.

    1993-01-01

    Barium sulfate suspension is routinely used as contrast medium for upper gastrointestinal procedures. It has been contraindicated for use in cases of suspected perforation. In such instances, water-soluble iodides are recommended for use. Most of the water-soluble iodides available for use in veterinary medicine at this time are hyperosmolar. This results in in transit dilution of the contrast column. The dilution of the contrast agent within the intestines may prevent visualization of a perforation, especially if the perforation is in the distal portion of the small intestine. Iohexol a nonionic water-soluble iodide of low osmolality, is currently used in veterinary medicine for myelography. We have used it as the contrast agent for upper gastrointestinal studies in cases of suspected obstruction or perforation, with good results, and no adverse effects have been associated with its use. Opacity of the contrast column was adequate, and segmentation or flocculation of the column was not apparent

  5. MRI contrast agents from molecules to particles

    CERN Document Server

    Laurent, Sophie; Stanicki, Dimitri; Boutry, Sébastien; Lipani, Estelle; Belaid, Sarah; Muller, Robert N; Vander Elst, Luce

    2017-01-01

    This book describes the multiple aspects of (i) preparation of the magnetic core, (ii) the stabilization with different coatings, (iii) the physico-chemical characterization and (iv) the vectorization to obtain specific nanosystems. Several bio-applications are also presented in this book. In the early days of Magnetic Resonance Imaging (MRI), paramagnetic ions were proposed as contrast agents to enhance the diagnostic quality of MR images. Since then, academic and industrial efforts have been devoted to the development of new and more efficient molecular, supramolecular and nanoparticular systems. Old concepts and theories, like paramagnetic relaxation, were revisited and exploited, leading to new scientific tracks. With their high relaxivity payload, the superparamagnetic nanoparticles are very appealing in the context of molecular imaging but challenges are still numerous: absence of toxicity, specificity, ability to cross the biological barriers, etc. .

  6. Large abnormal peak on capillary zone electrophoresis due to contrast agent.

    Science.gov (United States)

    Wheeler, Rachel D; Zhang, Liqun; Sheldon, Joanna

    2017-01-01

    Background Some iodinated radio-contrast media absorb ultraviolet light and can therefore be detected by capillary zone electrophoresis. If seen, these peaks are typically small with 'quantifications' of below 5 g/L. Here, we describe the detection of a large peak on capillary zone electrophoresis that was due to the radio-contrast agent, Omnipaque™. Methods Serum from a patient was analysed by capillary zone electrophoresis, and the IgG, IgA, IgM and total protein concentrations were measured. The serum sample was further analysed by gel electrophoresis and immunofixation. Results Capillary zone electrophoresis results for the serum sample showed a large peak with a concentration high enough to warrant urgent investigation. However, careful interpretation alongside the serum immunoglobulin concentrations and total protein concentration showed that the abnormal peak was a pseudoparaprotein rather than a monoclonal immunoglobulin. This was confirmed by analysis with gel electrophoresis and also serum immunofixation. The patient had had a CT angiogram with the radio-contrast agent Omnipaque™; addition of Omnipaque™ to a normal serum sample gave a peak with comparable mobility to the pseudoparaprotein in the patient's serum. Conclusions Pseudoparaproteins can appear as a large band on capillary zone electrophoresis. This case highlights the importance of a laboratory process that detects significant electrophoretic abnormalities promptly and interprets them in the context of the immunoglobulin concentrations. This should avoid incorrect reporting of pseudoparaproteins which could result in the patient having unnecessary investigations.

  7. Improved detection and biopsy of solid liver lesions using pulse-inversion ultrasound scanning and contrast agent infusion

    DEFF Research Database (Denmark)

    Skjoldbye, B.; Pedersen, Morten Høgholm; Struckmann, J.

    2002-01-01

    The purpose of this study was to assess the ability of pulse-inversion ultrasound (US) scanning (PIUS), combined with an IV contrast agent, to detect malignant liver lesions and its impact on patient management (resectability). Additionally, to determine the feasibility of US-guided biopsy of new...... PIUS-findings at the same session. A total of 30 patients with known or clinically suspected cancer underwent conventional B-mode scanning and PIUS with IV-administered contrast agent. The number of liver metastases in the right and the left liver lobe, respectively, was recorded. All patients...... findings were performed in 17 of 18 patients. All biopsies of additional findings confirmed malignancy. PIUS with an IV contrast agent increased the ability to detect liver metastases compared to conventional US scanning. The technique had a high impact on patient management. The results showed that PIUS...

  8. Methylene blue microbubbles as a model dual-modality contrast agent for ultrasound and activatable photoacoustic imaging

    Science.gov (United States)

    Jeon, Mansik; Song, Wentao; Huynh, Elizabeth; Kim, Jungho; Kim, Jeesu; Helfield, Brandon L.; Leung, Ben Y. C.; Goertz, David E.; Zheng, Gang; Oh, Jungtaek; Lovell, Jonathan F.; Kim, Chulhong

    2014-01-01

    Ultrasound and photoacoustic imaging are highly complementary modalities since both use ultrasonic detection for operation. Increasingly, photoacoustic and ultrasound have been integrated in terms of hardware instrumentation. To generate a broadly accessible dual-modality contrast agent, we generated microbubbles (a standard ultrasound contrast agent) in a solution of methylene blue (a standard photoacoustic dye). This MB2 solution was formed effectively and was optimized as a dual-modality contrast solution. As microbubble concentration increased (with methylene blue concentration constant), photoacoustic signal was attenuated in the MB2 solution. When methylene blue concentration increased (with microbubble concentration held constant), no ultrasonic interference was observed. Using an MB2 solution that strongly attenuated all photoacoustic signal, high powered ultrasound could be used to burst the microbubbles and dramatically enhance photoacoustic contrast (>800-fold increase), providing a new method for spatiotemporal control of photoacoustic signal generation.

  9. Contrast-enhanced NMR imaging: animal studies using gadolinium-DTPA complex

    International Nuclear Information System (INIS)

    Brasch, R.C.; Weinmann, H.J.; Wesbey, G.E.

    1984-01-01

    Gadolinium (Gd)-DTPA complex was assessed as a nuclear magnetic resonance (NMR) contrast-enhancing agent by experimentally imaging normal and diseased animals. After intravenous injection, Gd-DTPA, a strongly paramagnetic complex by virtue of unpaired electrons, was rapidly excreted into the urine of rats, producing an easily observable contrast enhancement on NMR images in kidney parenchyma and urine. Sterile soft-tissue abscesses demonstrated an obvious rim pattern of enhancement. A focus of radiation-induced brain damage in a canine model was only faintly detectable on spin-echo NMR images before contrast administration; after 0.5 mmol/kg Gd-DTPA administration, the lesion intensity increased from 3867 to 5590. In comparison, the normal brain with an intact blood-brain barrier remained unchanged in NMR characterization. Gd-DTPA is a promising new NMR contrast enhancer for the clinical assessment of renal function, of inflammatory lesions, and of focal disruption of the blood-brain barrier

  10. Acoustically active lipospheres containing paclitaxel: a new therapeutic ultrasound contrast agent.

    Science.gov (United States)

    Unger, E C; McCreery, T P; Sweitzer, R H; Caldwell, V E; Wu, Y

    1998-12-01

    Paclitaxel-carrying lipospheres (MRX-552) were developed and evaluated as a new ultrasound contrast agent for chemotherapeutic drug delivery. Paclitaxel was suspended in soybean oil and added to an aqueous suspension of phospholipids in vials. The headspace of the vials was replaced with perfluorobutane gas; the vials were sealed, and they were agitated at 4200 rpm on a shaking device. The resulting lipospheres containing paclitaxel were studied for concentration, size, acute toxicity in mice, and acoustic activity and drug release with ultrasound. Lipospheres containing sudan black dye were produced to demonstrate the acoustically active liposphere (AAL)-ultrasound release concept. Acoustically active lipospheres containing paclitaxel had a mean particle count of approximately 1 x 10(9) particles per mL and a mean size of 2.9 microns. Acute toxicity studies in mice showed a 10-fold reduction in toxicity for paclitaxel in AALs compared with free paclitaxel. The AALs reflected ultrasound as a contrast agent. Increasing amounts of ultrasound energy selectively ruptured the AALs and released the paclitaxel. Acoustically active lipospheres represent a new class of acoustically active drug delivery vehicles. Future studies will assess efficacy of AALs for ultrasound-mediated drug delivery.

  11. SU-E-QI-21: Iodinated Contrast Agent Time Course In Human Brain Metastasis: A Study For Stereotactic Synchrotron Radiotherapy Clinical Trials

    Energy Technology Data Exchange (ETDEWEB)

    Obeid, L; Esteve, F; Adam, J [Grenoble Institut des Neurosciences, La Tronche, Isere (France); Tessier, A; Balosso, J [Centre Hospitalier Universitaire, La Tronche, Isere (France)

    2014-06-15

    Purpose: Synchrotron stereotactic radiotherapy (SSRT) is an innovative treatment combining the selective accumulation of heavy elements in tumors with stereotactic irradiations using monochromatic medium energy x-rays from a synchrotron source. Phase I/II clinical trials on brain metastasis are underway using venous infusion of iodinated contrast agents. The radiation dose enhancement depends on the amount of iodine in the tumor and its time course. In the present study, the reproducibility of iodine concentrations between the CT planning scan day (Day 0) and the treatment day (Day 10) was assessed in order to predict dose errors. Methods: For each of days 0 and 10, three patients received a biphasic intravenous injection of iodinated contrast agent (40 ml, 4 ml/s, followed by 160 ml, 0.5 ml/s) in order to ensure stable intra-tumoral amounts of iodine during the treatment. Two volumetric CT scans (before and after iodine injection) and a multi-slice dynamic CT of the brain were performed using conventional radiotherapy CT (Day 0) or quantitative synchrotron radiation CT (Day 10). A 3D rigid registration was processed between images. The absolute and relative differences of absolute iodine concentrations and their corresponding dose errors were evaluated in the GTV and PTV used for treatment planning. Results: The differences in iodine concentrations remained within the standard deviation limits. The 3D absolute differences followed a normal distribution centered at zero mg/ml with a variance (∼1 mg/ml) which is related to the image noise. Conclusion: The results suggest that dose errors depend only on the image noise. This study shows that stable amounts of iodine are achievable in brain metastasis for SSRT treatment in a 10 days interval.

  12. In vivo cleavage rate of a dextran-bound magnetic resonance imaging contrast agent: preparation and intravascular pharmacokinetic characteristics in the rabbit.

    Science.gov (United States)

    Hals, Petter Arnt; Sontum, Per Christian; Holtz, Eckart; Klaveness, Jo; Rongved, Pål

    2013-02-01

    Earlier described dextran-based contrast agents for magnetic resonance imaging (MRI) comprising the gadolinium chelate diethylenetriamine pentaacetic acid (GdDTPA, 1) have shown significantly shorter in vivo contrast duration in rat than what would be expected from the initial average molecular weight (Mw) of the dextran fraction (71.4 kD). To investigate this further, four dextran fractions with given initial average molecular weight (Mw) of 10.4, 41.0, 71.4 and 580 kD were used as starting material to prepare products 2-5 where one of the carboxylic acid functionalities in GdDTPA was used as a direct covalent ester linker to hydroxyl groups in dextrans. A fifth derivative (6) was an amide-ester bound β-alanine-DTPAGd conjugate with dextran having Mw 71.4 kD. The reference compound GdDTPA (1) and gadoliniumlabelled dextran derivatives 2-6 were injected intravenously in rabbits. Pharmacokinetic parameters showed that when GdDTPA is ester-bound directly to dextran hydroxyls, the cleavage rates of 2-5 were only moderately dependent on the molecular weights of the dextrans, having blood pool half-lives comparable to the low-molecular reference compound (t 1/2,β 0.3 - 0.5 hrs.). Presence of a β-alanine spacer in 6 prolonged the plasma half-life t 1/2,β to 6.9 hours, rendering a blood residence time suitable for blood pool slow release of GdDTPA. Biological cleavage regenerates the clinically acceptable carrier dextran and the β-alanine derivative of GdDTPA, pointing at a clinically acceptable product class for blood-pool contrast in MRI.

  13. Efficacy and Tolerability of Intravenous Levetiracetam in Children

    Directory of Open Access Journals (Sweden)

    Jose eAceves

    2013-08-01

    Full Text Available Intractable epilepsy in children poses a serious medical challenge. Acute repetitive seizures and status epilepticus leads to frequent emergency room visits and hospital admissions. Permanent neurological damage can occur if there is delay in treatment. It has been shown that these children continue to remain intractable even after acute seizure management with approved FDA agents. Intravenous levetiracetam, a second-generation anticonvulsant was approved by the FDA in 2006 in patients 16 years and older as an alternative when oral treatment is not an option. It has been shown that oral levetiracetam can be used in the treatment of status epilepticus and acute repetitive seizures. Data have been published showing that intravenous levetiracetam is safe and efficacious, and can be used in an acute inpatient setting. This current review will discuss the recent data about the safety and tolerability of intravenous levetiracetam in children and neonates, and emphasize the need for a larger prospective multicenter trial to prove the efficacy of this agent in acute seizure management.

  14. Relationship between cavitation and loss of echogenicity from ultrasound contrast agents

    OpenAIRE

    Radhakrishnan, Kirthi; Bader, Kenneth B; Haworth, Kevin J; Kopechek, Jonathan A; Raymond, Jason L; Huang, Shao-Ling; McPherson, David D; Holland, Christy K

    2013-01-01

    Ultrasound contrast agents (UCAs) have the potential to nucleate cavitation and promote both beneficial and deleterious bioeffects in vivo. Previous studies have elucidated the pulse-duration dependent pressure amplitude threshold for rapid loss of echogenicity due to UCA fragmentation. Previous studies have demonstrated that UCA fragmentation was concomitant with inertial cavitation. The purpose of this study was to evaluate the relationship between stable and inertial cavitation thresholds ...

  15. Contrast induced nephropathy

    DEFF Research Database (Denmark)

    Stacul, Fulvio; van der Molen, Aart J; Reimer, Peter

    2011-01-01

    PURPOSE: The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 1999 guidelines on contrast medium-induced nephropathy (CIN). AREAS COVERED: Topics reviewed include the definition of CIN, the choice of contrast medium, the prophylactic me....../min/1.73 m (2) is CIN risk threshold for intravenous contrast medium. • Hydration with either saline or sodium bicarbonate reduces CIN incidence. • Patients with eGFR = 60 ml/min/1.73 m (2) receiving contrast medium can continue metformin normally....

  16. Quantitative comparison of tumor vascularity of HCC after intravenous contrast Agent: Conventional versus harmonic power Doppler US

    International Nuclear Information System (INIS)

    Park, Seong Ho; Kim, Tae Kyoung; Lee, Kyoung Ho; Kim, Ah Young; Han, Joon Koo; Choi, Byung Ihn

    1999-01-01

    For the quantitative comparison of the degree of enhancement in nodular hepatocellular carcinoma (HCC) at conventional and harmonic Power Doppler (PD) ultrasound (US). The average of %PDA of ten nodules gradually increased until 60 seconds after contrast injection and then gradually decreased. The average %PDA on conventional and harmonic PD US at 60 seconds were 34.9% and 19.5%, respectively. The average %PDA were significantly higher on conventional PD US than those on harmonic PD US at all times except at 20 seconds. The ratio of average %pda on conventional PD US to those on harmonic PD US became gradually larger after 120 seconds. Although contrast-enhanced harmonic PD US can be an effective method in evaluating the tumor vascularity of HCC because of less PD artifacts, the duration of effective enhancement was shorter and degree of enhancement is less than that of conventional PD US.

  17. Effect of X-ray contrast agents on hemostasis and its role in the genesis of adverse reactions

    International Nuclear Information System (INIS)

    Sviridov, N.K.; Napolov, Yu.K.

    2001-01-01

    Based on available data, the effect of X-ray contrast agents (XCA) on homeostasis and its role in side reactions genesis are discussed. It is shown that the contrast agent type used can essentially affect the thrombocytes. Nonionic XCA are able to increase the thrombocytes degranulation in case of coronarography and percutaneous transluminal coronary angioplastics with release of procoagulants in vessel gap. This effect can to lead to acute thromboses and be the start of restenosis [ru

  18. Design, synthesis, and evaluation of VEGFR-targeted macromolecular MRI contrast agent based on biotin?avidin-specific binding

    OpenAIRE

    Liu, Yongjun; Wu, Xiaoyun; Sun, Xiaohe; Wang, Dan; Zhong, Ying; Jiang, Dandan; Wang, Tianqi; Yu, Dexin; Zhang, Na

    2017-01-01

    Yongjun Liu,1 Xiaoyun Wu,1 Xiaohe Sun,1 Dan Wang,1 Ying Zhong,1 Dandan Jiang,1 Tianqi Wang,1 Dexin Yu,2 Na Zhang1 1School of Pharmaceutical Science, Shandong University, 2Department of Radiology Medicine, Qilu Hospital, Jinan, People’s Republic of China Abstract: Developing magnetic resonance imaging (MRI) contrast agents with high relaxivity and specificity was essential to increase MRI diagnostic sensitivity and accuracy. In this study, the MRI contrast agent, vascular endotheli...

  19. Synthesis of highly stable and biocompatible gold nanoparticles for use as a new X-ray contrast agent.

    Science.gov (United States)

    Iranpour, Pooya; Ajamian, Maral; Safavi, Afsaneh; Iranpoor, Nasser; Abbaspour, Abdolkarim; Javanmardi, Sanaz

    2018-04-18

    This work reports a novel reduction procedure for the synthesis of Gum Arabic (GA) capped-gold nanoparticles (AuNPs) in glucosammonium formate as a new ionic liquid. The GA coated AuNPs show good stability in physiological media. The synthesized AuNPs were characterized by UV-Vis spectroscopy, transmission electron microscopy, dynamic light scattering and X-ray diffraction analysis. These stable AuNPs are introduced as a new contrast agent for X-ray Computed Tomography (X-ray CT). These nanoparticles have higher contrasting properties than the commercial contrast agent, Visipaque. The precursors used (Gum Arabic and glucose based-ionic liquid) for synthesis of AuNPs are biocompatible and non-toxic.

  20. Contrast Agents for Micro-Computed Tomography of Microdamage in Bone

    Science.gov (United States)

    2011-01-01

    However, cracks in the enamel were readily detected by micro-CT both with and without the use of a con- trast agent (Fig. 2(b)) due to the relatively low x...ray attenua- tion of the fluid space in the crack compared to the enamel . Therefore, the main limitation of the difficulty distinguishing BaSO4 from...Roeder, 2011). Moreover, cracks in whole human molars were also imaged by contrast-enhanced micro-CT (Appendix 5, Landrigan et al., 2010). KEY