WorldWideScience

Sample records for intravascular ultrasound trial

  1. Harmonic Intravascular Ultrasound

    NARCIS (Netherlands)

    M.E. Frijlink (Martijn)

    2006-01-01

    textabstractMedical ultrasound is a popular imaging modality in cardiology. Harmonic Imaging is a technique that has been shown to increase the image quality of diagnostic ultrasound at frequencies below 10 MHz. However, Intravascular Ultrasound, which is a technique to acoustically investigate

  2. Angioplasty Guided by Intravascular Ultrasound: Meta-Analysis of Randomized Clinical Trials

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, José Albuquerque Neto de, E-mail: jafneto@cardiol.br; Nogueira, Iara Antonia Lustosa [Universidade Federal do Maranhão, São Luiz, MA (Brazil); Figueiro, Mabel Fernandes; Buehler, Anna Maria; Berwanger, Otavio [Instituto de Ensino e Pesquisa do Hospital do Coração, São Paulo, SP (Brazil)

    2013-08-15

    The impact of intravascular ultrasound (IVUS) use on stenting has shown inconclusive results. Systematic review and meta-analysis of the impact of IVUS on stenting regarding the clinical and angiographic evolution. A search was performed in Medline/Pubmed, CENTRAL, Embase, Lilacs, Scopus and Web of Science databases. It included randomized clinical trials (RCTs) that evaluated the implantation of stents guided by IVUS, compared with those using angiography alone (ANGIO). The minimum follow-up duration was six months and the following outcomes were assessed: thrombosis, mortality, myocardial infarction, percutaneous and surgical revascularization, major adverse cardiovascular events (MACE) and restenosis. The binary outcomes were presented considering the number of events in each group; the estimates were generated by a random effects model, considering Mantel-Haenszel statistics as weighting agent and magnitude of effect for the relative risk (RR) with its respective 95% confidence interval (95%CI). Higgins I{sup 2} test was used to quantify the consistency between the results of each study. A total of 2,689 articles were evaluated, including 8 RCTs. There was a 27% reduction in angiographic restenosis (RR: 0.73, 95% CI: 0.54-0.97, I{sup 2} = 51%) and statistically significant reduction in the rates of percutaneous revascularization and overall (RR: 0.88; 95% CI: 0.51 to 1.53, I{sup 2} = 61%, RR: 0.73, 95% CI: 0.54 to 0.99, I{sup 2} = 55%), with no statistical difference in surgical revascularization (RR: 0.95, 95% CI: 0.52-1.74, I{sup 2} = 0%) in favor of IVUS vs. ANGIO. There were no differences regarding the other outcomes in the comparison between the two strategies. Angioplasty with stenting guided by IVUS decreases the rates of restenosis and revascularization, with no impact on MACE, acute myocardial infarction, mortality or thrombosis outcomes.

  3. Angioplasty Guided by Intravascular Ultrasound: Meta-Analysis of Randomized Clinical Trials

    International Nuclear Information System (INIS)

    Figueiredo, José Albuquerque Neto de; Nogueira, Iara Antonia Lustosa; Figueiro, Mabel Fernandes; Buehler, Anna Maria; Berwanger, Otavio

    2013-01-01

    The impact of intravascular ultrasound (IVUS) use on stenting has shown inconclusive results. Systematic review and meta-analysis of the impact of IVUS on stenting regarding the clinical and angiographic evolution. A search was performed in Medline/Pubmed, CENTRAL, Embase, Lilacs, Scopus and Web of Science databases. It included randomized clinical trials (RCTs) that evaluated the implantation of stents guided by IVUS, compared with those using angiography alone (ANGIO). The minimum follow-up duration was six months and the following outcomes were assessed: thrombosis, mortality, myocardial infarction, percutaneous and surgical revascularization, major adverse cardiovascular events (MACE) and restenosis. The binary outcomes were presented considering the number of events in each group; the estimates were generated by a random effects model, considering Mantel-Haenszel statistics as weighting agent and magnitude of effect for the relative risk (RR) with its respective 95% confidence interval (95%CI). Higgins I 2 test was used to quantify the consistency between the results of each study. A total of 2,689 articles were evaluated, including 8 RCTs. There was a 27% reduction in angiographic restenosis (RR: 0.73, 95% CI: 0.54-0.97, I 2 = 51%) and statistically significant reduction in the rates of percutaneous revascularization and overall (RR: 0.88; 95% CI: 0.51 to 1.53, I 2 = 61%, RR: 0.73, 95% CI: 0.54 to 0.99, I 2 = 55%), with no statistical difference in surgical revascularization (RR: 0.95, 95% CI: 0.52-1.74, I 2 = 0%) in favor of IVUS vs. ANGIO. There were no differences regarding the other outcomes in the comparison between the two strategies. Angioplasty with stenting guided by IVUS decreases the rates of restenosis and revascularization, with no impact on MACE, acute myocardial infarction, mortality or thrombosis outcomes

  4. Mapping intravascular ultrasound controversies in interventional cardiology practice.

    Directory of Open Access Journals (Sweden)

    David Maresca

    Full Text Available Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound innovation has been relatively limited. Intravascular ultrasound remains a niche technology; its clinical practice did not vastly expand, except in Japan, where intravascular ultrasound is an appraised tool for guiding percutaneous coronary interventions. In this qualitative research study, we follow scholarship on the sociology of innovation in exploring both the current adoption practices and perspectives on the future of intravascular ultrasound. We conducted a survey of biomedical experts with experience in the technology, the practice, and the commercialization of intravascular ultrasound. The collected information enabled us to map intravascular ultrasound controversies as well as to outline the dynamics of the international network of experts that generates intravascular ultrasound innovations and uses intravascular ultrasound technologies. While the technology is praised for its capacity to measure coronary atherosclerotic plaque morphology and is steadily used in clinical research, the lack of demonstrated benefits of intravascular ultrasound guided coronary interventions emerges as the strongest factor that prevents its expansion. Furthermore, most of the controversies identified were external to intravascular ultrasound technology itself, meaning that decision making at the industrial, financial and regulatory levels are likely to determine the future of intravascular ultrasound. In light of opinions from the responding experts', a wider adoption of intravascular ultrasound as a stand-alone imaging modality seems rather uncertain, but the appeal for this technology may be renewed by improving image quality and through combination with

  5. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon- expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial

    NARCIS (Netherlands)

    J.M.R. Ligthart (Jürgen); M-C. Morice (Marie-Claude); P.J. de Feyter (Pim); M. Degertekin (Muzaffer); K. Tanabe (Kengo); J.E. Sousa (Eduardo); A. Colombo (Antonio); G. Guagliumi (Giulio); W. Wijns (William); W.K. Lindeboom (Wietze); P.W.J.C. Serruys (Patrick); A.C. Abizaid (Alexandre)

    2002-01-01

    textabstractBACKGROUND: The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent compared with an uncoated stent. METHODS AND RESULTS: In the RAVEL trial, 238

  6. Comparison of intravascular ultrasound versus angiography-guided drug-eluting stent implantation: A meta-analysis of one randomised trial and ten observational studies involving 19,619 patients

    NARCIS (Netherlands)

    Y. Zhang (Yaojun); V. Farooq (Vasim); H.M. Garcia-Garcia (Hector); C.V. Bourantas (Christos); N.-L. Tian (Nai-Liang); S.-J. Dong (Sheng-Jie); M. Li (Minghui); S. Yang (Shengyun); P.W.J.C. Serruys (Patrick); S.-L. Chen (Shao-Liang)

    2012-01-01

    textabstractAims: The impact of intravascular ultrasound (IVUS) guided coronary drug-eluting stent (DES) implantation on clinical outcomes remains controversial. A meta-analysis of the currently available clinical trials investi-gating IVUS-guided DES implantation was undertaken. Methods and

  7. Mapping Intravascular Ultrasound Controversies in Interventional Cardiology Practice

    NARCIS (Netherlands)

    Maresca, D.; Adams, S.; Maresca, B.; Van der Steen, A.F.W.

    2014-01-01

    Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound

  8. Mapping intravascular ultrasound controversies in interventional cardiology practice

    NARCIS (Netherlands)

    Maresca, David; Adams, Samantha; Maresca, Bruno; van der Steen, Antonius F W

    2014-01-01

    Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound

  9. Intravascular ultrasound-guided drug-eluting stent implantation: An updated meta-analysis of randomized control trials and observational studies.

    Science.gov (United States)

    Steinvil, Arie; Zhang, Yao-Jun; Lee, Sang Yeub; Pang, Si; Waksman, Ron; Chen, Shao-Liang; Garcia-Garcia, Hector M

    2016-08-01

    The use of intravascular ultrasound (IVUS) guidance for drug-eluting stent (DES) optimization is limited by the number of adequately powered randomized control trials (RCTs). We performed an updated meta-analysis, including data from recently published RCTs and observational studies, by reviewing the literature in Medline and the Cochrane Library to identify studies that compared clinical outcomes between IVUS-guided and angiography-guided DES implantation from January 1995 to January 2016. This meta-analysis included 25 eligible studies, including 31,283 patients, of whom 3192 patients were enrolled in 7 RCTs. In an analysis of all 25 studies, the summary results for all the events analyzed were significantly in favor of IVUS-guided DES implantation [major adverse cardiac events (MACE, odds ratio [OR] 0.76, 95% confidence intervals [CI]: 0.70-0.82, PDES implantation was found only for MACE (OR 0.66, 95% CI: 0.52-0.84, P=0.001), TLR (OR 0.61, 95% CI: 0.43-0.87, P=0.006), and TVR (OR 0.61, 95% CI: 0.41-0.90, P=0.013). IVUS-guided percutaneous coronary intervention was associated with better overall clinical outcomes than angiography-guided DES implantation. However, in a solely RCT meta-analysis, this benefit was mainly driven by reduced rates of revascularizations. Copyright © 2016. Published by Elsevier Ireland Ltd.

  10. Use of Intravascular Ultrasound Imaging in Percutaneous Coronary Intervention to Treat Left Main Coronary Artery Disease.

    Science.gov (United States)

    De Maria, Giovanni Luigi; Banning, Adrian P

    2017-05-01

    Due to its potential prognostic implications and technical complexity, revascularisation of left main coronary artery (LMCA) disease requires careful consideration. Since publication of the results of the SYNTAX study, and more recently the EXCEL and NOBLE trials, there has been particular interest in percutaneous revascularisation of the LMCA. It is becoming clear that percutaneous revascularisation of LMCA disease requires appropriate lesion preparation and carefully optimised stenting in order to offer patients a treatment option as effective as coronary artery bypass grafting. For this reason intravascular imaging, and especially intravascular ultrasound, is becoming a key procedural step in LMCA percutaneous coronary intervention. In the current review paper we analyse the role of intravascular imaging with intravascular ultrasound in LMCA percutaneous coronary intervention, focusing on the main applications in this context from lesion assessment to stent sizing and optimisation.

  11. Intravascular ultrasound-guided vs angiography-guided drug-eluting stent implantation in complex coronary lesions: Meta-analysis of randomized trials.

    Science.gov (United States)

    Bavishi, Chirag; Sardar, Partha; Chatterjee, Saurav; Khan, Abdur Rahman; Shah, Arpit; Ather, Sameer; Lemos, Pedro A; Moreno, Pedro; Stone, Gregg W

    2017-03-01

    The relative outcomes of intravascular ultrasound (IVUS)-guided percutaneous coronary intervention (PCI) compared with angiography-guided PCI with drug-eluting stent (DES) in complex lesions have not been established. We sought to compare the efficacy and safety of IVUS-guided PCI with angiography-guided PCI in patients with complex coronary lesions treated with DES. Electronic databases were searched to identify all randomized trials comparing IVUS-guided vs angiography-guided DES implantation. We evaluated major adverse cardiac events (MACE), all-cause and cardiovascular death, myocardial infarction, target lesion revascularization (TLR), target vessel revascularization (TVR), and stent thrombosis outcomes at the longest reported follow-up. Random-effects modeling was used to calculate pooled relative risk (RR) and 95% CIs. Eight trials comprising 3,276 patients (1,635 IVUS-guided and 1,641 angiography-guided) enrolling only patients with complex lesions were included. Mean follow-up was 1.4±0.5years. Compared with angiography-guided PCI, patients undergoing IVUS-guided PCI had significantly lower MACE (RR 0.64, 95% CI 0.51-0.80, P=.0001), TLR (RR 0.62, 95% CI 0.45-0.86, P=.004), and TVR (RR 0.60, 95% CI 0.42-0.87, P=.007). There were no significant differences for stent thrombosis, cardiovascular death, or all-cause death. In meta-regression analysis, IVUS-guided PCI was of greatest benefit in reducing MACE in patients with acute coronary syndromes, diabetes, and long lesions. The present meta-analysis demonstrates a significant reduction in MACE, TVR, and TLR with IVUS-guided DES implantation in complex coronary lesions. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Intravascular Ultrasound and its Use in Vascular Interventional Radiology

    International Nuclear Information System (INIS)

    Klepanec, A.; Vulev, I.; Vozar, M.; Balazs, T.; Madaric, J.; Holoman, M.

    2009-01-01

    Intravascular ultrasound has become in invasive vascular radiology in the last decade the important part of diagnostic and also therapeutic procedures in management of vascular diseases. The basic possibilities for the use of IVUS include diagnostic procedures in vascular pathology assessment and therapeutic indications in the field of peripheral vascular interventions (PVI). Unlike other image modalities (CT, MRI, ultrasound) IVUS enables gather unique image in r eal time r ight from the vessel lumen, what helps to add important information regarding vessel wall, plate morphology, thrombi and cross-sectional vessel area. After initial use of intravascular ultrasound in coronary circulation, using IVUS is nowadays widely extended especially in aortic diseases, carotid and renal arteries and arteries of the lower extremities. This review article summarizes possibilities of intravascular ultrasound utilization in diagnostic process and therapy from peripheral vascular diseases up to thoracoabdominal aorta diseases and our experience with this new diagnostic modality. (author)

  13. Does intravascular ultrasound provide clinical benefits for percutaneous coronary intervention with bare-metal stent implantation? A meta-analysis of randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Lodi-Junqueira Lucas

    2012-09-01

    Full Text Available Abstract Background The role of intravascular ultrasound (IVUS in percutaneous coronary interventions (PCI is still controversial despite several previously published meta-analyses. A meta-analysis to evaluate the controversial role of IVUS-guided PCI with bare-metal stenting was performed and a previous published meta-analysis was re-evaluated in order to clarify the discrepancy between results of these studies. Methods A systematic review was performed by an electronic search of the PubMed, Embase and Web of Knowledge databases and by a manual search of reference lists for randomized controlled trials published until April 2011, with clinical outcomes and, at least, six months of clinical follow-up. A meta-analysis based on the intention to treat was performed with the selected studies. Results Five studies and 1,754 patients were included. There were no differences in death (OR = 1.86; 95% CI = 0.88-3.95; p = 0.10, non-fatal myocardial infarction (OR = 0.65; 95% CI = 0.27-1.58; p = 0.35 and major adverse cardiac events (OR = 0.74; 95% CI = 0.49-1.13; p = 0.16. An analysis of the previous published meta-analysis strongly suggested the presence of publication bias. Conclusions There is no evidence to recommend routine IVUS-guided PCI with bare-metal stent implantation. This may be explained by the paucity and heterogeneity of the studies published so far.

  14. Discrimination of intravascular lumen and dissections in single intravascular ultrasound images using subtraction, conventional averaging and saline flush

    NARCIS (Netherlands)

    G. Pasterkamp (Gerard); M.S. van der Heiden (M.); M.J. Post (Mark); C. Borst (Cornelius); E.J. Gussenhoven (Elma); H. Pieterman; H. van Urk (Hero); N. Bom (Klaas)

    1995-01-01

    textabstractWith current 30-MHz intravascular ultrasound systems, flowing blood may cause considerable backscatter which in real-time images is characterized by dynamic speckle. However, in a single intravascular ultrasound image (still-frame) the discrimination between arterial lumen and wall may

  15. Mechanical scanning in intravascular ultrasound imaging: Artifacts and driving mechanisms

    NARCIS (Netherlands)

    H. ten Hoff (H.); E.J. Gussenhoven (Elma); C.M. Korbijn (Carin); F. Mastik (Frits); C.T. Lancée (Charles); N. Bom (Klaas)

    1995-01-01

    textabstractObjective: Currently, intravascular ultrasound (US) imaging catheters are developed and produced to provide a complementary diagnostic method in the treatment of blood vessel obstructive disease. Typical catheter dimensions are a diameter of 1–2.5 mm and a length of 1–1.5 m. A real-time

  16. An Axial Array for Volumetric Intravascular Ultrasound Imaging

    NARCIS (Netherlands)

    Alles, E.J.

    2012-01-01

    Intravascular ultrasound (IVUS) is a medical imaging modality aimed at imaging blood vessel walls from within the vessel. Current commercial IVUS catheters are designed to yield two-dimensional cross-sectional images perpendicular to the vessel wall. By pulling the catheter back through the artery

  17. Serial intravascular ultrasound assessment of changes in coronary atherosclerotic plaque dimensions and composition: an update

    DEFF Research Database (Denmark)

    Hartmann, Marc; Huisman, Jennifer; Böse, Dirk

    2011-01-01

    This manuscript reviews the use of serial intravascular ultrasound (IVUS) examination of coronary atherosclerosis in recent observational studies and randomized trials that revealed the effects of cholesterol-lowering and lipid-modifying therapies and offered novel insight into plaque progression....... Finally, we report on the evaluation of true vessel remodelling in recent serial IVUS trials and discuss the future perspective of serial invasive imaging of coronary atherosclerosis....

  18. Renal denervation by intravascular ultrasound: Preliminary in vivo study

    Science.gov (United States)

    Sinelnikov, Yegor; McClain, Steve; Zou, Yong; Smith, David; Warnking, Reinhard

    2012-10-01

    Ultrasound denervation has recently become a subject of intense research in connection with the treatment of complex medical conditions including neurological conditions, development of pain management, reproduction of skin sensation, neuropathic pain and spasticity. The objective of this study is to investigate the use of intravascular ultrasound to produce nerve damage in renal sympathetic nerves without significant injury to the renal artery. This technique may potentially be used to treat various medical conditions, such as hypertension. The study was approved by the Institutional Animal Care and Use Committee. Ultrasound was applied to renal nerves of the swine model for histopathological evaluation. Therapeutic ultrasound energy was delivered circumferentially by an intravascular catheter maneuvered into the renal arteries. Fluoroscopic imaging was conducted pre-and post-ultrasound treatment. Animals were recovered and euthanized up to 30 hours post procedure, followed by necropsy and tissue sample collection. Histopathological examination showed evidence of extensive damage to renal nerves, characterized by nuclear pyknosis, hyalinization of stroma and multifocal hemorrhages, with little or no damage to renal arteries. This study demonstrates the feasibility of intravascular ultrasound as a minimally invasive renal denervation technique. Further studies are necessary to evaluate the long-term safety and efficacy of this technique and its related clinical significance.

  19. Front-end IC design for intravascular ultrasound imaging

    OpenAIRE

    Yamaner, Yalçın Feysel; Yamaner, Yalcin Feysel; Cenkeramaddi, Linga Reddy; Bozkurt, Ayhan

    2008-01-01

    Capacitive micromachined ultrasonic transducers(cMUT) technology is a new trend for intravascular ultrasound (IVUS) imaging. Large bandwidth, high sensitivity and compatibility to CMOS processes makes the cMUT a better choice compared to the conventional piezoelectric transducer. To exploit the merits of cMUT technology, an accurately designed front end circuit is required. The circuit functions as an output pulse driver for the generation of the acoustic signal and buffers the return echo. F...

  20. Rotational multispectral fluorescence lifetime imaging and intravascular ultrasound: bimodal system for intravascular applications

    Science.gov (United States)

    Ma, Dinglong; Bec, Julien; Yankelevich, Diego R.; Gorpas, Dimitris; Fatakdawala, Hussain; Marcu, Laura

    2014-06-01

    We report the development and validation of a hybrid intravascular diagnostic system combining multispectral fluorescence lifetime imaging (FLIm) and intravascular ultrasound (IVUS) for cardiovascular imaging applications. A prototype FLIm system based on fluorescence pulse sampling technique providing information on artery biochemical composition was integrated with a commercial IVUS system providing information on artery morphology. A customized 3-Fr bimodal catheter combining a rotational side-view fiberoptic and a 40-MHz IVUS transducer was constructed for sequential helical scanning (rotation and pullback) of tubular structures. Validation of this bimodal approach was conducted in pig heart coronary arteries. Spatial resolution, fluorescence detection efficiency, pulse broadening effect, and lifetime measurement variability of the FLIm system were systematically evaluated. Current results show that this system is capable of temporarily resolving the fluorescence emission simultaneously in multiple spectral channels in a single pullback sequence. Accurate measurements of fluorescence decay characteristics from arterial segments can be obtained rapidly (e.g., 20 mm in 5 s), and accurate co-registration of fluorescence and ultrasound features can be achieved. The current finding demonstrates the compatibility of FLIm instrumentation with in vivo clinical investigations and its potential to complement conventional IVUS during catheterization procedures.

  1. Recurring extracranial internal carotid artery vasospasm detected by intravascular ultrasound.

    Science.gov (United States)

    Dembo, Tomohisa; Tanahashi, Norio

    2012-01-01

    A 24-year-old woman presented with headache and left-sided focal signs following multiple episodes of right monocular visual impairment. Magnetic resonance angiography revealed a decreased vascular image intensity due to a suspicious stenosis in the right internal carotid artery (ICA). The stenosis was not demonstrated on duplex sonography as it was beyond the field of view of the investigation. Intravascular ultrasound (IVUS) revealed that the outer vessel diameter was significantly reduced during stenosis, supporting the presence of vasospasm. Idiopathic recurrent extracranial ICA vasospasm was diagnosed. Recurrent vasospasms of extracranial ICA may be a distinct entity that can cause ischemic stroke.

  2. Late lumen loss and intima hyperplasia after sirolimus-eluting and zotarolimus-eluting stent implantation in diabetic patients: the diabetes and drug-eluting stent (DiabeDES III) angiography and intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Thayssen, Per

    2011-01-01

    Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to neointimal hyperplasia (NIH). The aim of this study was to use quantitative coronary angiography (QCA) and volumetric intravascular ultrasound (IVUS) to evaluate the effects...

  3. Accuracy of electrocardiographic-gated versus nongated volumetric intravascular ultrasound measurements of coronary arterial narrowing

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per

    2007-01-01

    Intravascular ultrasound (IVUS) allows precise measurements of plaque plus media (P+M) volume and neointimal hyperplasia after coronary artery stenting. Conventional IVUS volumetric analysis is performed mostly without electrocardiographically gated acquisition, and the IVUS images are selected...

  4. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels

    2013-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...

  5. Neointimal hyperplasia after sirolimus-eluting and paclitaxel-eluting stent implantation in diabetic patients: the Randomized Diabetes and Drug-Eluting Stent (DiabeDES) Intravascular Ultrasound Trial

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Thayssen, Per

    2008-01-01

    AIMS: Patients with diabetes have increased risk of in-stent restenosis after coronary stent implantation owing to neointimal hyperplasia (NIH). The aim of the study was to evaluate the extent and distribution of NIH with intravascular ultrasound (IVUS) after coronary artery stenting with sirolimus......-eluting (Cypher) or paclitaxel-eluting (Taxus) stents in diabetic patients. METHODS AND RESULTS: One hundred and thirty diabetic patients were randomized to Cypher or Taxus stent implantation. IVUS was performed at 8 month follow-up. NIH volume was significantly reduced in the Cypher group when compared...

  6. Re-examining minimal luminal diameter relocation and quantitative coronary angiography - Intravascular ultrasound correlations in stented saphenous vein grafts: Methodological insights from the randomised RRISC trial

    NARCIS (Netherlands)

    O. Semeraro (Oscar); P. Agostoni (Pierfrancesco); S. Verheye (Stefan); G.J.J. van Langenhove (Glenn); P.A. van den Heuvel (Paul); C. Convens (Carl); F. van den Branden (Frank); N. Bruining (Nico); P. Vermeersch (Paul)

    2009-01-01

    textabstractAims: Angiographic parameters (such as late luminal loss) are common endpoints in drug-eluting stent trials, but their correlation with the neointimal process and their reliability in predicting restenosis are debated. Methods and results: Using quantitative coronary angiography (QCA)

  7. Regression and shift in composition of coronary atherosclerotic plaques by pioglitazone: insight from an intravascular ultrasound analysis.

    Science.gov (United States)

    Clementi, Fabrizio; Di Luozzo, Marco; Mango, Ruggiero; Luciani, Giulio; Trivisonno, Antonio; Pizzuto, Francesco; Martuscelli, Eugenio; Mehta, Jawahar L; Romeo, Francesco

    2009-03-01

    Plaque reduction with the use of pioglitazone and statin combination therapy has been observed in carotid plaque. We sought to investigate the effect of combination therapy with statins and pioglitazone on coronary plaque regression and composition with the use of intravascular ultrasound (IVUS) and intravascular ultrasound-virtual histology (IVUS-VH). We analysed 29 plaques in 25 diabetic patients with angiographic evidence of nonsignificant coronary lesions with IVUS-VH. Patients were treated with 80 mg of atorvastatin and 30 mg of pioglitazone daily for 6 months. After 6 months of therapy, IVUS-VH of each lesion was reacquired. Mean elastic external membrane volume was significantly reduced between baseline and follow-up (343.9 vs. 320.5 mm; P < 0.05) as was mean total atheroma volume (179.3 vs. 166.6 mm; P < 0.05). Change in total atheroma volume showed a 6.3% mean reduction. Areas of fibrous tissue, fibrolipidic tissue and calcium decreased over the 6 months of follow-up, although not significantly. On the other hand, the necrotic core increased from 9 to 14% (P < 0.05). Our data demonstrated that atorvastatin/pioglitazone association is able to induce significant regression of coronary atherosclerosis, acting on plaque composition. Our findings are preliminary results and will be confirmed in an ongoing randomized placebo-controlled multicenter trial (PIPER; Pioglitazone for Prevention of Restenosis in Diabetics with Complex Lesion; trial registration: clinical trials.gov. Identifier: NCT 00376870).

  8. Design of low noise transimpedance amplifier for intravascular ultrasound

    KAUST Repository

    Reda, Dina

    2009-11-01

    In this paper, we study transimpedance amplifiers for capacitive sensing applications with a focus on Intravascular Ultra Sound (IVUS). We employ RF noise cancellation technique on capacitive feedback based transimpedance amplifiers. This technique eliminates the input-referred noise of TIAs completely and enhances the dynamic range of front-end electronics. Simulation results verify the proposed technique used in two different TIA topologies employing shunt-shunt feedback. ©2009 IEEE.

  9. Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.

    Science.gov (United States)

    Mariani, José; Guedes, Cristiano; Soares, Paulo; Zalc, Silvio; Campos, Carlos M; Lopes, Augusto C; Spadaro, André G; Perin, Marco A; Filho, Antonio Esteves; Takimura, Celso K; Ribeiro, Expedito; Kalil-Filho, Roberto; Edelman, Elazer R; Serruys, Patrick W; Lemos, Pedro A

    2014-11-01

    The aim of this study was to evaluate the impact of intravascular ultrasound (IVUS) guidance on the final volume of contrast agent used in patients undergoing percutaneous coronary intervention (PCI). To date, few approaches have been described to reduce the final dose of contrast agent in PCIs. We hypothesized that IVUS might serve as an alternative imaging tool to angiography in many steps during PCI, thereby reducing the use of iodine contrast. A total of 83 patients were randomized to angiography-guided PCI or IVUS-guided PCI; both groups were treated according to a pre-defined meticulous procedural strategy. The primary endpoint was the total volume contrast agent used during PCI. Patients were followed clinically for an average of 4 months. The median total volume of contrast was 64.5 ml (interquartile range [IQR]: 42.8 to 97.0 ml; minimum, 19 ml; maximum, 170 ml) in the angiography-guided group versus 20.0 ml (IQR: 12.5 to 30.0 ml; minimum, 3 ml; maximum, 54 ml) in the IVUS-guided group (p MOZART]; NCT01947335). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Low variation and high reproducibility in plaque volume with intravascular ultrasound

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Pedersen, Knud Erik

    2004-01-01

    BACKGROUND: Intravascular ultrasound (IVUS) has several advantages compared to angiography when evaluating coronary atherosclerosis in the vessel wall. METHODS: The accuracy, reproducibility, and short-time spontaneous variation in volume of vessel, plaque and lumen were studied by electrocardiog......BACKGROUND: Intravascular ultrasound (IVUS) has several advantages compared to angiography when evaluating coronary atherosclerosis in the vessel wall. METHODS: The accuracy, reproducibility, and short-time spontaneous variation in volume of vessel, plaque and lumen were studied...... by electrocardiographic-gated three-dimensional (3D) IVUS in 20 male patients with ischaemic heart disease (IHD). RESULTS: The study lesions were angiographically insignificant, with a length of the analysed segment on 11.4+/-5.9 mm. At baseline the mean minimal lumen diameter was 2.41+/-0.59 mm, minimal lumen area 4......=0.804; pIVUS is a highly reproducible method when applied on coronary artery...

  11. Reliability of mechanical and phased-array designs for serial intravascular ultrasound examinations--animal and clinical studies in stented and non-stented coronary arteries.

    Science.gov (United States)

    Tardif, J C; Bertrand, O F; Mongrain, R; Lespérance, J; Grégoire, J; Paiement, P; Bonan, R

    2000-10-01

    Both mechanical and multi-element intravascular ultrasound designs have potential advantages and limitations that may impact on their value for clinical and research purposes. Determination of the reproducibility of measurements is critical before a given system can be used in studies such as regression of atherosclerosis trials. We performed serial intravascular ultrasound imaging with catheters using mechanical and phased-array designs in stented and non-stented coronary arteries in dogs and in patients. Both systems correlated well for areas (r > or = 0.90, p or = 0.84. p mechanical designs for measurements of area (mean difference in dogs and in patients: -0.24 and 0.96 mm2, p mechanical system (r > or = 0.96 for all measurements). The differences in absolute and relative variability between the mechanical and phased-array designs, both for reanalysis of same frames and serial pullbacks, were very small. Although multi-element and mechanical intravascular ultrasound designs are not strictly interchangeable, their similar reproducibility and the small differences in measurements demonstrate that both designs are acceptable alternatives for trials of regression of atherosclerosis. Determination of the variability for serial pullbacks of both designs was also important to assess the statistical power of such trials.

  12. Association of insulin resistance and coronary artery remodeling: an intravascular ultrasound study

    OpenAIRE

    Kim, Sang-Hoon; Moon, Jae-Youn; Lim, Yeong Min; Kim, Kyung Ho; Yang, Woo-In; Sung, Jung-Hoon; Yoo, Seung Min; Kim, In Jai; Lim, Sang-Wook; Cha, Dong-Hun; Cho, Seung-Yun

    2015-01-01

    Background There are few studies that investigated the correlation between insulin resistance (IR) and the coronary artery remodeling. The aim of the study is to investigate the association of IR measured by homeostasis model assessment of insulin resistance (HOMA-IR) and coronary artery remodeling evaluated by intravascular ultrasound (IVUS). Methods A total of 298 consecutive patients who received percutaneous coronary interventions under IVUS guidance were retrospectively enrolled. The val...

  13. Monolithic CMUT on CMOS Integration for Intravascular Ultrasound Applications

    Science.gov (United States)

    Zahorian, Jaime; Hochman, Michael; Xu, Toby; Satir, Sarp; Gurun, Gokce; Karaman, Mustafa; Degertekin, F. Levent

    2012-01-01

    One of the most important promises of capacitive micromachined ultrasonic transducer (CMUT) technology is integration with electronics. This approach is required to minimize the parasitic capacitances in the receive mode, especially in catheter based volumetric imaging arrays where the elements need to be small. Furthermore, optimization of the available silicon area and minimized number of connections occurs when the CMUTs are fabricated directly above the associated electronics. Here, we describe successful fabrication and performance evaluation of CMUT arrays for intravascular imaging on custom designed CMOS receiver electronics from a commercial IC foundry. The CMUT on CMOS process starts with surface isolation and mechanical planarization of the CMOS electronics to reduce topography. The rest of the CMUT fabrication is achieved by modifying a low temperature micromachining process through the addition of a single mask and developing a dry etching step to produce sloped sidewalls for simple and reliable CMUT to CMOS interconnection. This CMUT to CMOS interconnect method reduced the parasitic capacitance by a factor of 200 when compared with a standard wire bonding method. Characterization experiments indicate that the CMUT on CMOS elements are uniform in frequency response and are similar to CMUTs simultaneously fabricated on standard silicon wafers without electronics integration. Experiments on a 1.6 mm diameter dual-ring CMUT array with a 15 MHz center frequency show that both the CMUTs and the integrated CMOS electronics are fully functional. The SNR measurements indicate that the performance is adequate for imaging CTOs located 1 cm away from the CMUT array. PMID:23443701

  14. Monolithic CMUT-on-CMOS integration for intravascular ultrasound applications.

    Science.gov (United States)

    Zahorian, Jaime; Hochman, Michael; Xu, Toby; Satir, Sarp; Gurun, Gokce; Karaman, Mustafa; Degertekin, F Levent

    2011-12-01

    One of the most important promises of capacitive micromachined ultrasonic transducer (CMUT) technology is integration with electronics. This approach is required to minimize the parasitic capacitances in the receive mode, especially in catheter-based volumetric imaging arrays, for which the elements must be small. Furthermore, optimization of the available silicon area and minimized number of connections occurs when the CMUTs are fabricated directly above the associated electronics. Here, we describe successful fabrication and performance evaluation of CMUT arrays for intravascular imaging on custom-designed CMOS receiver electronics from a commercial IC foundry. The CMUT-on-CMOS process starts with surface isolation and mechanical planarization of the CMOS electronics to reduce topography. The rest of the CMUT fabrication is achieved by modifying a low-temperature micromachining process through the addition of a single mask and developing a dry etching step to produce sloped sidewalls for simple and reliable CMUT-to-CMOS interconnection. This CMUT-to-CMOS interconnect method reduced the parasitic capacitance by a factor of 200 when compared with a standard wire-bonding method. Characterization experiments indicate that the CMUT-on-CMOS elements are uniform in frequency response and are similar to CMUTs simultaneously fabricated on standard silicon wafers without electronics integration. Ex- periments on a 1.6-mm-diameter dual-ring CMUT array with a center frequency of 15 MHz show that both the CMUTs and the integrated CMOS electronics are fully functional. The SNR measurements indicate that the performance is adequate for imaging chronic total occlusions located 1 cm from the CMUT array.

  15. Intravascular ultrasound assessment of remodelling and reference segment plaque burden in type-2 diabetic patients

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Mintz, Gary S

    2007-01-01

    AIMS: Intravascular ultrasound (IVUS) assesses arterial remodelling by comparing the lesion external elastic membrane (EEM) with the reference segments; however, reference segments are rarely disease-free. The aim was to assess lesion and reference segment remodelling and plaque burden in patients...... with type-2 diabetes mellitus. METHODS AND RESULTS: We used pre-intervention IVUS to study 62 de novo lesions in 43 patients with type-2 diabetes mellitus. The lesion site was the image slice with the smallest lumen cross-sectional area (CSA). The proximal and distal reference segments were the most normal...... IVUS lumen and quantitative coronary angiographic artery...

  16. Successful Intravascular Ultrasound-Guided Transradial Coronary Intervention with a 4Fr Guiding Catheter.

    Science.gov (United States)

    Nakano, Yasuhiro; Sadamatsu, Kenji

    2016-01-01

    Minimizing the catheter size can reduce vascular access complications and contrast dye usage in coronary angiography. The small diameter of the 4Fr guiding catheter has limited the use of several angioplasty devices such as intravascular ultrasound (IVUS) in the past. However, the combination of a novel IVUS catheter and a 0.010 guidewire makes it possible to perform IVUS-guided percutaneous coronary intervention (PCI) with a 4Fr guiding catheter. We herein report the case of a 51-year-old man with silent myocardial ischemia who underwent IVUS-guided transradial PCI with a 4Fr guiding catheter.

  17. Offline fusion of co-registered intravascular ultrasound and frequency domain optical coherence tomography images for the analysis of human atherosclerotic plaques

    DEFF Research Database (Denmark)

    Räber, Lorenz; Heo, Jung Ho; Radu, Maria D

    2012-01-01

    To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images.......To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images....

  18. Intravascular ultrasound assessment of minimumlumen area and intimal hyperplasia in in-stent restenosis after drug-eluting or bare-metal stent implantation. The Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Vikman, Saila; Antonsen, Lisbeth

    2017-01-01

    Introduction: Drug-eluting stents (DES) reduce the risk of restenosis after percutaneous coronary intervention. The aim of the study was to evaluate, by intravascular ultrasound (IVUS), the minimum lumen area site in the stented segment and the distribution of intimal hyperplasia in patients...

  19. Multicenter assessment of the reproducibility of volumetric radiofrequency-based intravascular ultrasound measurements in coronary lesions that were consecutively stented

    DEFF Research Database (Denmark)

    Huisman, Jennifer; Egede, Rasmus; Rdzanek, Adam

    2012-01-01

    To assess in a multicenter design the between-center reproducibility of volumetric virtual histology intravascular ultrasound (VH-IVUS) measurements with a semi-automated, computer-assisted contour detection system in coronary lesions that were consecutively stented. To evaluate the reproducibility...

  20. Relationship between intravascular ultrasound parameters and fractional flow reserve in intermediate coronary artery stenosis of left anterior descending artery: intravascular ultrasound volumetric analysis.

    Science.gov (United States)

    Yang, Hyoung-Mo; Tahk, Seung-Jea; Lim, Hong-Seok; Yoon, Myeong-Ho; Choi, So-Yeon; Choi, Byoung-Joo; Jin, Xiong Jie; Hwang, Gyo-Seung; Park, Jin-Sun; Shin, Joon-Han

    2014-02-15

    The objective of this study was to assess the relationship between intravascular ultrasound (IVUS) parameters, including volumetric analysis, and fractional flow reserve (FFR). Although it is known that coronary atherosclerosis burden measured by IVUS volumetric analysis is related with clinical outcomes, its relationship with functional significance remains unknown. Both IVUS and FFR were performed in 206 cases of intermediate stenosis of the left anterior descending artery (LAD). Myocardial ischemia was assessed by FFR and maximal hyperemia was induced by continuous intracoronary adenosine infusion. FFR  0.80 were associated with larger plaque volume (181.8 ± 82.3 vs. 125.9 ± 77.9 mm3, P < 0.001) and PAV (58.9 ± 5.6 vs. 53.8 ± 7.9%, P < 0.001). IVUS parameters representing severity and extent of atheromatous plaque correlated with functional significance in LAD lesions with intermediate stenosis.

  1. Characterization of a saphenous vein graft aneurysm by intravascular ultrasound and computerized three-dimensional reconstruction.

    Science.gov (United States)

    Ennis, B M; Zientek, D M; Ruggie, N T; Billhardt, R A; Klein, L W

    1993-04-01

    Aneurysmal dilatations in saphenous vein grafts are rare complications of coronary artery bypass surgery that mostly represent thin-wall pseudoaneurysms at anastomotic sites. We describe a case of an enlarging distal saphenous vein graft aneurysm in which intravascular ultrasound (IVUS) and computerized three-dimensional reconstruction (3DR) of the IVUS images was performed to conclusively demonstrate true aneurysm morphology. Although both atherosclerotic and nonatherosclerotic mechanisms for vein graft aneurysm formation have been previously suggested, IVUS images and 3DR of the aneurysm in this case did not reveal any of the features typical for atherosclerotic lesions. Further, the IVUS images and 3DR suggest that progressive atherosclerosis is not the likely cause of aneurysm formation in this case. This application of IVUS and 3DR provides detailed information about saphenous vein graft aneurysm structure, clues to aneurysm formation, and suggests a natural history that may differ from that of pseudoaneurysms.

  2. Quantification of iliac artery stenoses: a methodological comparative study between intravascular ultrasound, arteriography and duplex scanning

    DEFF Research Database (Denmark)

    Vogt, K C; Rasmussen, John Bøje Grønvall; Skovgaard, Lene T

    1998-01-01

    Two morphological methods for quantifying the degree of stenoses in the iliac arteries, intravascular ultrasound (IVUS) and arteriography, were compared with duplex scanning, a method of evaluating the haemodynamic importance of the stenosis. A total of 38 patients, 20 women and 18 men, median age...... 66 y, admitted for either PTA (n=18) or femoro-femoral crossover bypass surgery (n=20), were examined by IVUS, single plane arteriography and duplex scanning. The predictive value, sensitivity, specificity and kappa value of IVUS were higher than the corresponding values for arteriography. Logistic...... regression analysis found that IVUS had a predictive value (p=0.0003) for diagnosing significant stenosis as defined by duplex scanning, but arteriography did not (p=0.1). However, this difference in usefulness as predictors did not reach significance. The agreement between arteriography and IVUS...

  3. The use of intravascular ultrasound for intraoperative assessment during semiclosed thromboendarterectomy

    DEFF Research Database (Denmark)

    Vogt, K C; Sillesen, H; Schroeder, T V

    1998-01-01

    To evaluate the application of intravascular ultrasound (IVUS) for intraoperative assessment of semiclosed thromboendarterectomy (TEA), IVUS images of the iliofemoral segment in 20 patients were obtained. The configuration and size of residual atherosclerotic material were evaluated. Stenoses...... was detected in the artery by IVUS. The material was removed in five cases. The part of the iliac artery proximal to the endarterectomized segment was visualized in 14 cases and showed minor stenoses in 10 cases. After follow-up at a median of 8 months (range 1-24), occlusion had occurred in one of 20 patients...... and restenosis (> 50%) had developed in two (10%). At this point, patency cannot be related to IVUS findings. We conclude that IVUS is a feasible method for intraoperative assessment of semiclosed TEA. The rate of early failures due to residual material might be reduced by this new application of IVUS....

  4. The role of Intravascular Ultrasound in the management of spontaneous coronary artery dissection

    Directory of Open Access Journals (Sweden)

    Karamitsos Theodoros D

    2008-05-01

    Full Text Available Abstract Primary or spontaneous coronary artery dissection (SCAD is an unusual but increasingly recognized cause of acute myocardial ischemia and sudden cardiac death. Typically, SCAD presents in younger patients without conventional risk factors for coronary artery disease. It occurs more commonly in women than in men, and frequently during pregnancy or the postpartum period. Its pathophysiology is poorly understood, and there is considerable controversy regarding the optimal management of patients with SCAD-related myocardial ischemia. Therapeutic approaches include conservative medical therapy, coronary artery bypass graft surgery and percutaneous coronary intervention (PCI. We present four cases of SCAD to illustrate specific aspects of the presentation and management of this condition, with particular reference to the importance of intravascular ultrasound (IVUS to aid diagnosis and guide subsequent PCI.

  5. Comparison of angiography and intravascular ultrasound before and after balloon angioplasty of the femoropopliteal artery

    International Nuclear Information System (INIS)

    Lankeren, Winnifred van; Gussenhoven, Elma J.; Pieterman, Herman; Sambeek, Marc R. H. M. van; Lugt, Aad van der

    1998-01-01

    Purpose: To compare angiographic and intravascular ultrasound (IVUS) data before and after balloon angioplasty (PTA) of the femoropopliteal artery.Methods: Qualitative and quantitative analyses were performed on corresponding angiographic and IVUS levels obtained from 135 patients.Results: IVUS detected more lesions, calcified lesions, and vascular damage than angiography. Sensitivity of angiography was good for the presence of a lesion (84%), moderate for eccentric lesions (53%) and for vascular damage (52%), and poor for calcified lesions (30%). The increase in angiographic diameter stenosis was associated with a decrease in lumen area and increase in percentage area stenosis on IVUS.Conclusions: Angiography is less sensitive than IVUS for detecting lesion eccentricity, calcified lesions, and vascular damage. Presence of a lesion and amount of plaque were underestimated angiographically. Only before PTA was good agreement found between angiographic diameter stenosis and lumen size on IVUS.

  6. Perspectives on Imaging the Left Main Coronary Artery Using Intravascular Ultrasound and Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Harry C Lowe

    2015-01-01

    Full Text Available Percutaneous Coronary Intervention (PCI for significant left main coronary artery (LMCA stenosis is increasingly being viewed as a viable alternative to Coronary Artery Bypass Grafting (CABG (1. This is leading to an expectation of increasing numbers of such procedures, with a consequent focus on both the ability to image both lesion severity, and assess more accurately the results of PCI. While there have been advances in physiologic assessment of left main severity using fractional flow reserve (FFR, imaging of the LMCA using Intravascular Ultrasound (IVUS and more recently Optical Coherence Tomography (OCT has the specific advantage of being able to provide detailed anatomical information both pre and post PCI, such that it is timely to review briefly the current status of these two imaging technologies in the context of LMCA intervention.

  7. The Imaging Modulography Technique Revisited for High-Definition Intravascular Ultrasound: Theoretical Framework.

    Science.gov (United States)

    Tacheau, Antoine; Le Floc'h, Simon; Finet, Gérard; Doyley, Marvin M; Pettigrew, Roderic I; Cloutier, Guy; Ohayon, Jacques

    2016-03-01

    Mechanical characterization of atherosclerotic lesions remains an essential step for the detection of vulnerable plaques (VPs). Recently, an intravascular ultrasound (IVUS) elasticity reconstruction method (iMOD) has been tested in vivo by our group. The major limitation of iMOD is the need to estimate the strain field in the entire VP despite attenuated depth penetration signals when using high-definition (HD) IVUS systems. Therefore, an extended iMOD approach (E-iMOD) was designed and applied to coronary lesions of patients imaged in vivo with IVUS. The E-iMOD method (i) quantified necrotic core areas with a mean absolute relative error of 3.5 ± 3.5% and (ii) identified Young's moduli of the necrotic cores and fibrous regions with mean values of 5.7 ± 0.8 kPa and 794.5 ± 22.0 kPa instead of 5 kPa and 800 kPa, respectively. This study demonstrates the potential of the improved HD-IVUS modulography technique E-iMOD to characterize coronary VPs. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. All rights reserved.

  8. Monitoring of allograft vasculopathy by intravascular ultrasound one month and one year after heart transplantation: A single center study.

    Science.gov (United States)

    Bedanova, Helena; Orban, Marek; Tretina, Martin; Fila, Petr; Horvath, Vladimir; Krejci, Jan; Nemec, Petr

    2016-03-01

    The aim of this trial was to use intravascular ultrasound (IVUS) to determine whether cardiac allograft vasculopathy (CAV) starts progressing during the first year after heart transplantation (HTx). We retrospectively analyzed 51 patients (11 women) who received heart transplants in our center between January 2010 and September 2013 and underwent coronary angiography as well as IVUS examination one month and one year after HTx. Patients with proven calcification and fibrotic plates in the IVUS examination one month after HTx constituted a group with defined donor-transmitted atherosclerosis (DTA). In patients without DTA, measurements of maximal intimal thickening (MIT) were made in two predetermined locations. Eight of the 51 patients had DTA, while 43 did not. These were divided based on maximal intimal thickness (MIT) into a group with MIT first year after HTx significantly more frequently in patients with DTA and MIT ≥ 0.5 mm. It is essential in these patients to implement an IVUS control examination one year after transplantation. The results can lead to a change in treatment strategy to prevent further progress of the disease.

  9. Resolution of spontaneous coronary artery dissection within 3 weeks detected by computed tomography angiography and intravascular ultrasound.

    Science.gov (United States)

    Tsutsui, Hiroshi; Chino, Chiharu; Komatsu, Miho; Sakai, Takahiro; Aizawa, Kazunori; Owa, Mafumi

    2017-01-01

    A 62-year-old woman was admitted with chest pain lasting about 3 h. Spontaneous coronary artery dissection (SCAD) was detected in the left anterior descending artery (LAD) by intravascular ultrasound (IVUS). Sixteen days after onset, follow-up computed tomography angiography was performed and revealed shrinkage of the false lumen of the SCAD. On hospital day 22, IVUS image confirmed that the SCAD in the LAD was completely healed. This case shows the possibility of rapid healing of SCAD.

  10. Angled-focused 45 MHz PMN-PT single element transducer for intravascular ultrasound imaging.

    Science.gov (United States)

    Yoon, Sangpil; Williams, Jay; Kang, Bong Jin; Yoon, Changhan; Cabrera-Munoz, Nestor; Jeong, Jong Seob; Lee, Sang Goo; Shung, K Kirk; Kim, Hyung Ham

    2015-06-01

    A transducer with an angled and focused aperture for intravascular ultrasound imaging has been developed. The acoustic stack for the angled-focused transducer was made of PMN-PT single crystal with one matching layer, one protective coating layer, and a highly damped backing layer. It was then press-focused to a desired focal length and inserted into a thin needle housing with an angled tip. A transducer with an angled and unfocused aperture was also made, following the same fabrication procedure, to compare the performance of the two transducers. The focused and unfocused transducers were tested to measure their center frequencies, bandwidths, and spatial resolutions. Lateral resolution of the angled-focused transducer (AFT) improved more than two times compared to that of the angled-unfocused transducer (AUT). A tissue-mimicking phantom in water and a rabbit aorta tissue sample in rabbit blood were scanned using AFT and AUT. Imaging with AFT offered improved contrast, over imaging with AUT, of the tissue-mimicking phantom and the rabbit aorta tissue sample by 23 dB and 8 dB, respectively. The results show that AFT has strong potential to provide morphological and pathological information of coronary arteries with high resolution and high contrast.

  11. Expansion in calcific lesions and overall clinical outcomes following bioresorbable scaffold implantation optimized with intravascular ultrasound.

    Science.gov (United States)

    Kawamoto, Hiroyoshi; Ruparelia, Neil; Latib, Azeem; Miyazaki, Tadashi; Sato, Katsumasa; Tanaka, Akihito; Naganuma, Toru; Sticchi, Alessandro; Chieffo, Alaide; Carlino, Mauro; Montorfano, Matteo; Colombo, Antonio

    2017-04-01

    This study aimed to investigate clinical outcomes following bioresorbable scaffold (BRS) optimized with intravascular ultrasound (IVUS), and furthermore expansion of BRS in calcific lesions. Although IVUS use has contributed to improved clinical outcomes with metallic stent implantation, it is unclear if this is also true with regards to BRS, especially in calcified lesions. Between May 2012 and April 2015, 291 lesions in 198 patients were treated with BRS with IVUS use. We evaluated overall clinical outcomes at 1-year and investigated the expansion and eccentricity index of BRS amongst quadrants categorized by calcium arc (CA) every 90-degrees. The rates of major adverse cardiac events were 5.4% (at 6 months) and 10.7% (at 12 months). TLR was observed in 3.1% at 6-month and 7.5% at 12-month follow up. Although there was a significant difference among quadrants regarding to eccentricity of calcium (0°≦CA BRS expansion index [minimal scaffold area (MSA) divided by BRS area expanded at a nominal pressure] was comparable between quadrants. The use of IVUS to optimize BRS implantation results in favorable clinical outcomes even for complex lesions. Although eccentric calcium distribution resulted in asymmetric expansion of BRS, the final MSA was comparable irrespective of calcium distribution. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Determinants of slow flow following stent implantation in intravascular ultrasound-guided primary percutaneous coronary intervention.

    Science.gov (United States)

    Watanabe, Yusuke; Sakakura, Kenichi; Taniguchi, Yousuke; Yamamoto, Kei; Wada, Hiroshi; Fujita, Hideo; Momomura, Shin-Ichi

    2018-03-01

    Slow flow is a serious complication in primary percutaneous coronary intervention (PCI) and is associated with poor clinical outcomes. Intravascular ultrasound (IVUS)-guided PCI may improve clinical outcomes after drug-eluting stent implantation. The purpose of this study was to seek the factors of slow flow following stent implantation, including factors related to IVUS-guided primary PCI. The study population consisted of 339 ST-elevation myocardial infarction patients, who underwent stent deployment with IVUS. During PCI, 56 patients (16.5%) had transient or permanent slow flow. Multivariate logistic regression analysis showed age (OR 1.04, 95% CI 1.01-1.07, P = 0.01), low attenuation plaque on IVUS (OR 3.38, 95% CI 1.70-6.72, P = 0.001), initial Thrombolysis In Myocardial Infarction (TIMI) flow grade 2 (vs. TIMI 0: OR 0.44, 95% CI 0.20-0.99, P = 0.046), and the ratio of stent diameter to vessel diameter (per 0.1 increase: OR 2.63, 95% CI 1.84-3.77, P flow. A ratio of stent diameter to vessel diameter of 0.71 had an 80.4% sensitivity and 56.9% specificity to predict slow flow. There was no significant difference in ischemic-driven target vessel revascularization between the modest stent expansion (ratio of stent diameter to vessel diameter flow following stent implantation in IVUS-guided primary PCI.

  13. Visualization of plaque distribution in a curved artery: three-dimensional intravascular ultrasound imaging.

    Science.gov (United States)

    Choi, Ahnryul; McPherson, David D; Kim, Hyunggun

    2017-12-01

    Intravascular ultrasound (IVUS) imaging provides an excellent tool for evaluation of the type, morphology, extent, and severity of an atheromatous plaque. 3 D IVUS imaging offers additive information pertaining to morphology of the arterial structures and volumetric plaque distributions. A new 3 D IVUS visualization technique was developed to provide 3 D structural information of a curved artery. A virtual 3 D curved arterial phantom consisting of varying cross-sectional shapes, wall thicknesses, and acoustic intensity information was utilized to validate the nonlinear interpolation technique to create intermediary 2 D IVUS images. IVUS imaging was performed for the iliofemoral arterial segment of an atherosclerotic Yucatan miniswine model. These in-vivo IVUS data were utilized for intermediary IVUS image generation and volumetric 3 D IVUS visualization. Smooth transitional changes of cross-sectional shape, wall thickness and grayscale intensity were found between the intermediary images and the original arterial phantom slices. The 3 D IVUS imaging of the unfolded curved iliofemoral artery provided realistic 3 D luminal surface images of the arteries with physiologic grayscale intensity information. This unique 3 D IVUS imaging technique may help with assessment of 3 D plaque distribution across the curved arterial structure, and improve 3 D visualization of atheromatous components.

  14. Towards a Reduced-Wire Interface for CMUT-Based Intravascular Ultrasound Imaging Systems.

    Science.gov (United States)

    Lim, Jaemyung; Tekes, Coskun; Degertekin, F Levent; Ghovanloo, Maysam

    2017-04-01

    Having intravascular ultrasound (IVUS) imaging capability on guide wires used in cardiovascular interventions may eliminate the need for separate IVUS catheters and expand the use of IVUS in a larger portion of the vasculature. High frequency capacitive micro machined ultrasonic transducer (CMUT) arrays should be integrated with interface electronics and placed on the guide wire for this purpose. Besides small size, this system-on-a-chip (SoC) front-end should connect to the back-end imaging system with a minimum number of wires to preserve the critical mechanical properties of the guide wire. We present a 40 MHz CMUT array interface SoC, which will eventually use only two wires for power delivery and transmits image data using a combination of analog-to-time conversion (ATC) and an impulse radio ultra-wideband (IR-UWB) wireless link. The proof-of-concept prototype ASIC consumes only 52.8 mW and occupies 4.07 [Formula: see text] in a 0.35- [Formula: see text] standard CMOS process. A rectifier and regulator power the rest of the SoC at 3.3 V from a 10 MHz power carrier that is supplied through a 2.4 m micro-coax cable with an overall efficiency of 49.1%. Echo signals from an 8-element CMUT array are amplified by a transimpedance amplifier (TIA) array and down-converted to baseband by quadrature sampling using a 40 MHz clock, derived from the power carrier. The ATC generates pulse-width-modulated (PWM) samples at 2 × 10 MS/s with 6 bit resolution, while the entire system achieved 5.1 ENOB. Preliminary images from the prototype system are presented, and alternative data transmission and possible future directions towards practical implementation are discussed.

  15. Correlation between dual-axis rotational coronary angiography and intravascular ultrasound in a coronary lesion assessment.

    Science.gov (United States)

    Jin, Zhi-Geng; Zhang, Zhuo-Qi; Jing, Li-Min; Wei, Yu-Jie; Zhang, Jiao; Luo, Jian-Ping; Yang, Sheng-Li; Ma, Dong-Xing; Liu, Ying; Han, Wei; Yang, Yong; Liu, Hui-Liang

    2017-02-01

    The purpose of this study was to evaluate the accuracy of dual-axis rotational coronary angiography (DARCA) for coronary lesion assessment by directly comparing with intravascular ultrasound (IVUS). From October 2014 to December 2015, 40 patients (58 lesions) who had undergone both DARCA and IVUS were included in the image analysis. The minimum lumen diameter (MLD), lesion length, reference vessel diameter (RVD) and percent diameter stenosis at the same lesion, were identified and assessed. Significant correlation with IVUS was found for DARCA in either lesion length (r = 0.90, P < 0.001) or RVD (r = 0.81, P < 0.001) comparison. DARCA had fair correlation with IVUS for both MLD (r = 0.65, P < 0.001) and diameter stenosis (r = 0.48, P < 0.001). From the Bland-Altman plots, there was a good agreement between DARCA and IVUS regarding MLD (mean difference: -0.23 mm, 95 % limits of agreement: -0.96 to 0.50 mm) and RVD (mean difference: -0.15 mm, 95 % limits of agreement: -0.85 to 0.55 mm), while lesser agreement was found on lesion length (mean difference: -3.39 mm, 95 % limits of agreement: -12.63 to 5.85 mm) and diameter stenosis (mean difference: 4.82 %, 95 % limits of agreement: -17.05 to 26.68 %). There is an adequate correlation and agreement between DARCA and IVUS in coronary lesion assessment.

  16. Abnormal pulmonary artery stiffness in pulmonary arterial hypertension: in vivo study with intravascular ultrasound.

    Directory of Open Access Journals (Sweden)

    Edmund M T Lau

    Full Text Available BACKGROUND: There is increasing recognition that pulmonary artery stiffness is an important determinant of right ventricular (RV afterload in pulmonary arterial hypertension (PAH. We used intravascular ultrasound (IVUS to evaluate the mechanical properties of the elastic pulmonary arteries (PA in subjects with PAH, and assessed the effects of PAH-specific therapy on indices of arterial stiffness. METHOD: Using IVUS and simultaneous right heart catheterisation, 20 pulmonary segments in 8 PAH subjects and 12 pulmonary segments in 8 controls were studied to determine their compliance, distensibility, elastic modulus and stiffness index β. PAH subjects underwent repeat IVUS examinations after 6-months of bosentan therapy. RESULTS: AT BASELINE, PAH SUBJECTS DEMONSTRATED GREATER STIFFNESS IN ALL MEASURED INDICES COMPARED TO CONTROLS: compliance (1.50±0.11×10(-2 mm(2/mmHg vs 4.49±0.43×10(-2 mm(2/mmHg, p<0.0001, distensibility (0.32±0.03%/mmHg vs 1.18±0.13%/mmHg, p<0.0001, elastic modulus (720±64 mmHg vs 198±19 mmHg, p<0.0001, and stiffness index β (15.0±1.4 vs 11.0±0.7, p = 0.046. Strong inverse exponential associations existed between mean pulmonary artery pressure and compliance (r(2 = 0.82, p<0.0001, and also between mean PAP and distensibility (r(2 = 0.79, p = 0.002. Bosentan therapy, for 6-months, was not associated with any significant changes in all indices of PA stiffness. CONCLUSION: Increased stiffness occurs in the proximal elastic PA in patients with PAH and contributes to the pathogenesis RV failure. Bosentan therapy may not be effective at improving PA stiffness.

  17. Multimodality Intracoronary Imaging With Near-Infrared Spectroscopy and Intravascular Ultrasound in Asymptomatic Individuals With High Calcium Scores.

    Science.gov (United States)

    Madder, Ryan D; VanOosterhout, Stacie; Klungle, David; Mulder, Abbey; Elmore, Matthew; Decker, Jeffrey M; Langholz, David; Boyden, Thomas F; Parker, Jessica; Muller, James E

    2017-10-01

    This study sought to determine the frequency of large lipid-rich plaques (LRP) in the coronary arteries of individuals with high coronary artery calcium scores (CACS) and to determine whether the CACS correlates with coronary lipid burden. Combined near-infrared spectroscopy and intravascular ultrasound was performed in 57 vessels in 20 asymptomatic individuals (90% on statins) with no prior history of coronary artery disease who had a screening CACS ≥300 Agatston units. Among 268 10-mm coronary segments, near-infrared spectroscopy images were analyzed for LRP, defined as a bright yellow block on the near-infrared spectroscopy block chemogram. Lipid burden was assessed as the lipid core burden index (LCBI), and large LRP were defined as a maximum LCBI in 4 mm ≥400. Vessel plaque volume was measured by quantitative intravascular ultrasound. Vessel-level CACS significantly correlated with plaque volume by intravascular ultrasound ( r =0.69; P infrared spectroscopy ( r =0.24; P =0.07). Despite a high CACS, no LRP was detected in 8 (40.0%) subjects. Large LRP having a maximum LCBI in 4 mm ≥400 were infrequent, found in only 5 (25.0%) of 20 subjects and in only 5 (1.9%) of 268 10-mm coronary segments analyzed. Among individuals with a CACS ≥300 Agatston units mostly on statins, CACS correlated with total plaque volume but not LCBI. This observation may have implications on coronary risk among individuals with a high CACS considering that it is coronary LRP, rather than calcification, that underlies the majority of acute coronary events. © 2017 American Heart Association, Inc.

  18. Optical Coherence Tomography Analysis of Attenuated Plaques Detected by Intravascular Ultrasound in Patients with Acute Coronary Syndromes

    Directory of Open Access Journals (Sweden)

    Takashi Kubo

    2011-01-01

    Full Text Available Background. Recent intravascular ultrasound (IVUS studies have demonstrated that hypoechoic plaque with deep ultrasound attenuation despite absence of bright calcium is common in acute coronary syndrome. Such “attenuated plaque” may be an IVUS characteristic of unstable lesion. Methods. We used optical coherence tomography (OCT in 104 patients with unstable angina to compare lesion characteristics between IVUS-detected attenuated plaque and nonattenuated plaque. Results. IVUS-detected attenuated plaque was observed in 41 (39% patients. OCT-detected lipidic plaque (88% versus 49%, <0.001, thin-cap fibroatheroma (48% versus 16%, <0.001, plaque rupture (44% versus 11%, <0.001, and intracoronary thrombus (54% versus 17%, <0.001 were more often seen in IVUS-detected attenuated plaques compared with nonattenuated plaques. Conclusions. IVUS-detected attenuated plaque has many characteristics of unstable coronary lesion. The presence of attended plaque might be an important marker of lesion instability.

  19. Intravascular Ultrasound Catheter Evaluation of the Left Ventricle in Mice: A Feasibility Study.

    Science.gov (United States)

    Gardin, Julius M.; Siri, Francis; Kitsis, Richard N.; Leinwand, Leslie

    1996-11-01

    With the advent of transgenic technology, it has become increasingly important to find a method for evaluating left ventricular (LV) anatomy and function in intact wild type, intervened, and transgenic mice. Mice are 1/10th the size of rats, and have body masses of 10-60 g, LV masses of 40-150 mg, LV wall thicknesses of 0.5-2 mm, and LV internal dimensions of 1-3 mm. Although the murine LV has been imaged by transthoracic (TTE) two-dimensional directed M-mode echocardiography, we explored the use of intravascular ultrasound (IVUS) catheters, with imaging from various positions, to see if better two-dimensional images of the LV could be obtained by IVUS than TTE. Eight normal mice were anesthetized using pentobarbital or avertin. The mice were studied using a commercially available IVUS system (Endosonics, Inc.). Two IVUS catheters (3.5 and 5.0 Fr) with 20-MHz multielement array transducers were used. Each catheter had a 4.0-mm imaging depth of field in all directions (360 degrees ) from the mid-point of the catheter core. Multiple imaging approaches were attempted: transesophageal (TEE); transjugular (TJ); transperitoneal (TP); and open chest, from both epicardial surface (Ep) and via direct LV puncture. TEE and TJ approaches afforded insufficient depth of field to image the entire LV in cross section. TP and Ep approaches resulted in poor images, related both to inadequate depth of field and to relatively small sector angles subtended by imaging elements. LVP (intracavitary imaging) was capable of satisfactorily imaging the LV epicardium, but was unable to image the endocardium, probably because the latter was within the 1.9-mm "ringdown" catheter artifact. All IVUS approach studies lacked sufficient temporal resolution (10 frames/sec) to reliably display systolic and diastolic frames necessary for evaluation of LV function. In contrast, as previously reported, transthoracic two-dimensionally directed M-mode echocardiograms have sufficient temporal and spatial

  20. Natural history of intravascular ultrasound-detected edge dissections from coronary stent deployment.

    Science.gov (United States)

    Sheris, S J; Canos, M R; Weissman, N J

    2000-01-01

    High-resolution intravascular ultrasound (IVUS) performed immediately after stent deployment often reveals dissection at the stent margin that may not be appreciated by angiography. However, the natural history of these edge dissections is unknown. These intimal disruptions at the stent margins have been previously reported to occur in 5% to 23% of stent implantations. The short-term prognosis of these lesions appears to be good; however, the longer-term effect on restenosis and/or vessel remodeling is not known. We therefore studied a cohort of patients with the use of IVUS immediately after stent implantation and at 6 months to assess the incidence and prognosis of coronary edge dissections. One hundred fifty patients undergoing Palmaz-Shatz stent implantation were imaged with IVUS with the use of a motorized pullback, and the incidence of edge dissections was determined and graded according to depth and circumferential extent. Arterial and lesional morphometric parameters were assessed by digital planimetry. Six-month IVUS images were aligned with the poststent IVUS to determine the natural history of these lesions. Sixteen (10.7%) of 150 had edge tears. All were angiographically silent. Most lesions (n = 9) were superficial intimal tears. Vessel, lumen, and plaque area were similar in the nondissection and dissection groups in both the proximal and distal reference segments. Plaque eccentricity was likewise similar in both groups. At 6 months, lesions (n = 12) healed without a change in plaque burden, undergoing a "tacking down" process. Vessel area (19. 1 +/- 6.4 vs 18.4 +/- 7.1 mm(2), P = not significant), lumen area (8. 2 +/- 4.1 vs 9.2 +/- 4.0 mm(2), P = not significant), and plaque area (10.0 +/- 3.3 vs 9.8 +/- 3.3 mm(2), P = not significant) were unchanged when compared with the lesion site taken at stent deployment. Edge dissections as detected by IVUS do not necessarily proscribe an adverse prognosis at 6 months. This finding may provide reassurance to

  1. Segmentation of arterial walls in intravascular ultrasound cross-sectional images using extremal region selection.

    Science.gov (United States)

    Faraji, Mehdi; Cheng, Irene; Naudin, Iris; Basu, Anup

    2018-03-01

    Intravascular Ultrasound (IVUS) is an intra-operative imaging modality that facilitates observing and appraising the vessel wall structure of the human coronary arteries. Segmentation of arterial wall boundaries from the IVUS images is not only crucial for quantitative analysis of the vessel walls and plaque characteristics, but is also necessary for generating 3D reconstructed models of the artery. The aim of this study is twofold. Firstly, we investigate the feasibility of using a recently proposed region detector, namely Extremal Region of Extremum Level (EREL) to delineate the luminal and media-adventitia borders in IVUS frames acquired by 20 MHz probes. Secondly, we propose a region selection strategy to label two ERELs as lumen and media based on the stability of their textural information. We extensively evaluated our selection strategy on the test set of a standard publicly available dataset containing 326 IVUS B-mode images. We showed that in the best case, the average Hausdorff Distances (HD) between the extracted ERELs and the actual lumen and media were 0.22  mm and 0.45 mm, respectively. The results of our experiments revealed that our selection strategy was able to segment the lumen with ⩽0.3 mm HD to the gold standard even though the images contained major artifacts such as bifurcations, shadows, and side branches. Moreover, when there was no artifact, our proposed method was able to delineate media-adventitia boundaries with 0.31 mm HD to the gold standard. Furthermore, our proposed segmentation method runs in time that is linear in the number of pixels in each frame. Based on the results of this work, by using a 20 MHz IVUS probe with controlled pullback, not only can we now analyze the internal structure of human arteries more accurately, but also segment each frame during the pullback procedure because of the low run time of our proposed segmentation method. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)

    Science.gov (United States)

    de Jaegere, P; Mudra, H; Figulla, H; Almagor, Y; Doucet, S; Penn, I; Colombo, A; Hamm, C; Bartorelli, A; Rothman, M; Nobuyoshi, M; Yamaguchi, T; Voudris, V; DiMario, C; Makovski, S; Hausmann, D; Rowe, S; Rabinovich, S; Sunamura, M; van Es, G A

    1998-08-01

    A study was set up to validate the safety and feasibility of intravascular ultrasound-guided stenting without subsequent anticoagulation, and its impact on the 6 months restenosis rate. The study was designed to be multicentred, prospective, and observational. One hundred and sixty-one patients with stable angina and a de novo coronary artery lesion were enrolled. In four patients, the implantation of a Palmaz-Schatz (with spiral bridge) stent had failed. One of these four patients died 3 days following bypass surgery. In two other patients, intravascular ultrasound assessment was not performed. One hundred and twenty-five of the remaining 155 patients (81%) were treated with aspirin (100 mg x day(-1)), because all three criteria for optimized stent expansion were met. Twenty-two of the remaining 38 patients (25%), in whom at least one criterion was not met were treated with aspirin and acenocoumarol (3 months, INR 2.5-3.5), while 16 patients only received aspirin. Stent thrombosis was documented in two patients (1.3%) for which repeat angioplasty was performed. During the hospital stay, there were no deaths or Q-wave myocardial infarctions. Five patients (3.2%) sustained a non-Q-wave myocardial infarction. During the follow-up period (198+/-38 days, complete for all patients, except one), one patient (0.6%) sustained a Q-wave myocardial infarction, one (0.6%) underwent bypass surgery, and repeat angioplasty was performed in nine patients (5.7%). In two of the nine patients, repeat angioplasty involved another lesion. Therefore, the target lesion revascularization rate during follow-up was 4.5% (seven patients). At quantitative coronary angiography, the minimal lumen diameter (mean+/-SD) increased from 1.12+/-0.34 mm before to 2.89+/-0.35 mm after stenting. Repeat angiography at 6 months was performed in 144 patients (92%). The minimal lumen diameter at follow-up was 2.12+/-0.67 mm. Restenosis (diameter stenosis of 50% or more) was documented in 12 patients or 8

  3. Reproducibility of intravascular ultrasound radiofrequency data analysis (virtual histology) with a 45-MHz rotational imaging catheter in ex vivo human coronary arteries

    NARCIS (Netherlands)

    T. Muramatsu (Takashi); H.M. Garcia-Garcia (Hector); S. Brugaletta (Salvatore); J.H. Heo (Jungho); Y. Onuma (Yoshinobu); R.J. Fedewa (Russell J.); A. Nair (Anuja); Y. Ozaki (Yukio); P.W.J.C. Serruys (Patrick)

    2015-01-01

    textabstractBackground: Despite the frequent use of spectral analysis of intravascular ultrasound radiofrequency data (VH® IVUS) in clinical studies, the assessment for reproducibility using this with high frequency IVUS remains unexplored. Purpose: The aim of this study was to examine the

  4. 3-D ultrasound imaging using a forward-looking CMUT ring array for intravascular/intracardiac applications.

    Science.gov (United States)

    Yeh, David T; Oralkan, Omer; Wygant, Ira O; O'Donnell, Matthew; Khuri-Yakub, Butrus T

    2006-06-01

    Forward-viewing ring arrays can enable new applications in intravascular and intracardiac ultrasound. This work presents compelling, full-synthetic, phased-array volumetric images from a forward-viewing capacitive micromachined ultrasonic transducer (CMUT) ring array wire bonded to a custom integrated circuit front end. The CMUT ring array has a diameter of 2 mm and 64 elements each 100 microm x 100 microm in size. In conventional mode, echo signals received from a plane reflector at 5 mm had 70% fractional bandwidth around a center frequency of 8.3 MHz. In collapse mode, 69% fractional bandwidth is measured around 19 MHz. Measured signal-to-noise ratio (SNR) of the echo averaged 16 times was 29 dB for conventional operation and 35 dB for collapse mode. B-scans were generated of a target consisting of steel wires 0.3 mm in diameter to determine resolution performance. The 6 dB axial and lateral resolutions for the B-scan of the wire target are 189 microm and 0.112 radians for 8 MHz, and 78 microm and 0.051 radians for 19 MHz. A reduced firing set suitable for real-time, intravascular applications was generated and shown to produce acceptable images. Rendered three-dimensional (3-D) images of a Palmaz-Schatz stent also are shown, demonstrating that the imaging quality is sufficient for practical applications.

  5. Cardiac allograft vasculopathy compared by intravascular ultrasound sonography: everolimus to mycophenolate mofetil--one single-center experience.

    Science.gov (United States)

    Chou, N-K; Jan, C-F; Chi, N-H; Lee, C-M; Wu, I-H; Huang, S-C; Chen, Y-S; Yu, H-Y; Tsao, C-I; Ko, W-J; Chu, S-H; Wang, S-S

    2012-05-01

    Cardiac allograft vasculopathy (CAV) remains one of the leading causes of late graft failure and death. Cyclosporine microemulsion Neoral (CsA) had been used in heart transplantation (HTx) recipients. Meanwhile, Everolimus (EVL; Certican, Norvatis Pharmaceuticals; Basel, Switzerland) or mycophenolate mofetil (MMF) have been combined with CsA for maintenance treatment. We compared atherosclerosis in HTx patients showing CAV by intravascular ultrasound (IVUS) in two groups: the CE who received CsA, EVL, and steroid versus the CM group, who received CsA, MMF, and steroid. We explored IVUS parameters such as plaque thickness (PT), lumen circumference (LC), media adventitial circumference, lumen diameter (LD), and media adventitial diameter to characterize the atherosclerosis among CE versus CM groups. In this study, both the CE and CM groups showed increased plaque thickening in the first year posttransplantation (P data. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Comparison of intravascular ultrasound and angiographic assessement of coronary reference segment size in patients with type 2 diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Mintz, Gary S

    2008-01-01

    During percutaneous coronary intervention, the reference segment is assessed angiographically. This report described the discrepancy between angiographic and intravascular ultrasound (IVUS) assessment of reference segment size in patients with type 2 diabetes mellitus. Preintervention IVUS was used...... was measured as plaque CSA/external elastic membrane (EEM) CSA. Using IVUS, the reference lumen diameter was 2.80 +/- 0.42 mm and the reference EEM diameter was 4.17 +/- 0.56 mm. The angiographic reference diameter was 2.63 +/- 0.36 mm. Mean difference between the IVUS EEM diameter and angiographic reference...... diameter was 1.56 +/- 0.55 mm. The mean difference between the IVUS reference lumen diameter and angiographic reference lumen diameter was 0.18 +/- 0.44 mm. Plaque burden in the reference segment correlated inversely with the difference between IVUS and quantitative coronary angiographic reference lumen...

  7. Intravascular ultrasound as a novel tool for the diagnosis and targeted treatment of functional popliteal artery entrapment syndrome

    Directory of Open Access Journals (Sweden)

    Anna E. Boniakowski, MD

    2017-06-01

    Full Text Available Functional popliteal artery entrapment syndrome can be difficult to diagnose, as the imaging modalities presently employed are designed to detect anatomic entrapment. We describe a novel imaging technique to aid in diagnosis in this cohort. A 22-year-old cyclist presented with exercise-limiting claudication. Magnetic resonance angiography with provocative maneuvers was nondiagnostic. Digital subtraction angiography revealed long-segment occlusion of the popliteal artery with plantar flexion; however, the specific site of compression remained unclear. Intravascular ultrasound allowed specific localization of compression and further confirmed the diagnosis. Thus, we report this as an adjunctive imaging modality to definitively diagnose functional popliteal artery entrapment syndrome and to assist in operative planning.

  8. Results of the ICTuS 2 Trial (Intravascular Cooling in the Treatment of Stroke 2).

    Science.gov (United States)

    Lyden, Patrick; Hemmen, Thomas; Grotta, James; Rapp, Karen; Ernstrom, Karin; Rzesiewicz, Teresa; Parker, Stephanie; Concha, Mauricio; Hussain, Syed; Agarwal, Sachin; Meyer, Brett; Jurf, Julie; Altafullah, Irfan; Raman, Rema

    2016-12-01

    Therapeutic hypothermia is a potent neuroprotectant approved for cerebral protection after neonatal hypoxia-ischemia and cardiac arrest. Therapeutic hypothermia for acute ischemic stroke is safe and feasible in pilot trials. We designed a study protocol to provide safer, faster therapeutic hypothermia in stroke patients. Safety procedures and 4°C saline infusions for faster cooling were added to the ICTuS trial (Intravascular Cooling in the Treatment of Stroke) protocol. A femoral venous intravascular cooling catheter after intravenous recombinant tissue-type plasminogen activator in eligible patients provided 24 hours cooling followed by a 12-hour rewarm. Serial safety assessments and imaging were performed. The primary end point was 3-month modified Rankin score 0,1. Of the intended 1600 subjects, 120 were enrolled before the study was stopped. Randomly, 63 were to receive hypothermia plus antishivering treatment and 57 normothermia. Compared with previous studies, cooling rates were improved with a cold saline bolus, without fluid overload. The intention-to-treat primary outcome of 90-day modified Rankin Score 0,1 occurred in 33% hypothermia and 38% normothermia subjects, odds ratio (95% confidence interval) of 0.81 (0.36-1.85). Serious adverse events occurred equally. Mortality was 15.9% hypothermia and 8.8% normothermia subjects, odds ratio (95% confidence interval) of 1.95 (0.56-7.79). Pneumonia occurred in 19% hypothermia versus 10.5% in normothermia subjects, odds ratio (95% confidence interval) of 1.99 (0.63-6.98). Intravascular therapeutic hypothermia was confirmed to be safe and feasible in recombinant tissue-type plasminogen activator-treated acute ischemic stroke patients. Protocol changes designed to reduce pneumonia risk appeared to fail, although the sample is small. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01123161. © 2016 American Heart Association, Inc.

  9. The clinical importance and prediction of steal following femoro-femoral cross-over bypass: study of the donor iliac artery by intravascular ultrasound, arteriography, duplex scanning and pressure measurements

    DEFF Research Database (Denmark)

    Vogt, K C; Rasmussen, J G; Schroeder, T V

    2000-01-01

    to evaluate the clinical significance of the steal phenomenon following femoro-femoral bypass, and whether the addition of intravascular ultrasound (IVUS) to the established examinations of the donor iliac artery can improve the prediction of patients who will develop steal.......to evaluate the clinical significance of the steal phenomenon following femoro-femoral bypass, and whether the addition of intravascular ultrasound (IVUS) to the established examinations of the donor iliac artery can improve the prediction of patients who will develop steal....

  10. Dynamic contrast enhanced ultrasound assessment of the vascular effects of novel therapeutics in early stage trials.

    Science.gov (United States)

    Leen, Edward; Averkiou, Michalakis; Arditi, Marcel; Burns, Peter; Bokor, Daniela; Gauthier, Thomas; Kono, Yuko; Lucidarme, Olivier

    2012-07-01

    Imaging is key in the accurate monitoring of response to cancer therapies targeting tumour vascularity to inhibit its growth and dissemination. Dynamic contrast enhanced ultrasound (DCE ultrasound) is a quantitative method with the advantage of being non-invasive, widely available, portable, cost effective, highly sensitive and reproducible using agents that are truly intravascular. Under the auspices of the initiative of the Experimental Cancer Medicine Centre Imaging Network, bringing together experts from the UK, Europe and North America for a 2-day workshop in May 2010, this consensus paper aims to provide guidance on the use of DCE ultrasound in the measurement of tumour vascular support in clinical trials. Key Points • DCE ultrasound can quantify and extract specific blood flow parameters, such as flow velocity, relative vascular volume and relative blood flow rate. • DCE ultrasound can be performed repeatedly and is therefore ideally suited for pharmacokinetic and pharmacodynamic studies evaluating vascular-targeted drugs. • DCE ultrasound provides a reproducible method of assessing the vascular effects of therapy in pre-clinical and early clinical trials, which is easily translatable into routine clinical practice.

  11. Clinical feasibility of 3D automated coronary atherosclerotic plaque quantification algorithm on coronary computed tomography angiography: Comparison with intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyung-Bok [Yonsei University Health System, Yonsei-Cedar Sinai Integrative Cardiovascular Imaging Research Center, Seoul (Korea, Republic of); Myongji Hospital, Division of Cardiology, Cardiovascular Center, Goyang (Korea, Republic of); Lee, Byoung Kwon [Yonsei University College of Medicine, Division of Cardiology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Shin, Sanghoon [Yonsei University Health System, Yonsei-Cedar Sinai Integrative Cardiovascular Imaging Research Center, Seoul (Korea, Republic of); National Health Insurance Corporation Ilsan Hospital, Division of Cardiology, Goyang (Korea, Republic of); Heo, Ran; Chang, Hyuk-Jae; Chung, Namsik [Yonsei University Health System, Yonsei-Cedar Sinai Integrative Cardiovascular Imaging Research Center, Seoul (Korea, Republic of); Yonsei University Health System, Division of Cardiology, Severance Cardiovascular Hospital, Seoul (Korea, Republic of); Arsanjani, Reza [Cedars-Sinai Medical Center, Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Los Angeles, CA (United States); Kitslaar, Pieter H. [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Medis medical Imaging Systems B.V., Leiden (Netherlands); Broersen, Alexander; Dijkstra, Jouke [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Ahn, Sung Gyun [Yonsei University Wonju Severance Christian Hospital, Division of Cardiology, Wonju (Korea, Republic of); Min, James K. [New York-Presbyterian Hospital, Institute for Cardiovascular Imaging, Weill-Cornell Medical College, New York, NY (United States); Hong, Myeong-Ki; Jang, Yangsoo [Yonsei University Health System, Division of Cardiology, Severance Cardiovascular Hospital, Seoul (Korea, Republic of)

    2015-10-15

    To evaluate the diagnostic performance of automated coronary atherosclerotic plaque quantification (QCT) by different users (expert/non-expert/automatic). One hundred fifty coronary artery segments from 142 patients who underwent coronary computed tomography angiography (CCTA) and intravascular ultrasound (IVUS) were analyzed. Minimal lumen area (MLA), maximal lumen area stenosis percentage (%AS), mean plaque burden percentage (%PB), and plaque volume were measured semi-automatically by expert, non-expert, and fully automatic QCT analyses, and then compared to IVUS. Between IVUS and expert QCT analysis, the correlation coefficients (r) for the MLA, %AS, %PB, and plaque volume were excellent: 0.89 (p < 0.001), 0.84 (p < 0.001), 0.91 (p < 0.001), and 0.94 (p < 0.001), respectively. There were no significant differences in the mean parameters (all p values >0.05) except %AS (p = 0.01). The automatic QCT analysis showed comparable performance to non-expert QCT analysis, showing correlation coefficients (r) of the MLA (0.80 vs. 0.82), %AS (0.82 vs. 0.80), %PB (0.84 vs. 0.73), and plaque volume (0.84 vs. 0.79) when they were compared to IVUS, respectively. Fully automatic QCT analysis showed clinical utility compared with IVUS, as well as a compelling performance when compared with semiautomatic analyses. (orig.)

  12. Accuracy of multidetector row computed tomography for the detection of transplant vasculopathy: comparison with invasive coronary angiography and intravascular ultrasound

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Carrascosa, J.; Perrone, S.; Deviggiano, A.; Lopez, E.M.; Lev, G.; Garcia, M.J.

    2009-01-01

    Objective: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for detection of luminal stenosis and cardiac allograft vasculopathy in comparison with coronary angiography (CA) and intravascular ultrasound (IVUS) respectively. Material and methods: Nineteen cardiac transplant patients scheduled for follow-up CA were included. MDCT coronary angiography was performed using a 16-row CT scanner within 7-14 days after CA and IVUS. Studies were analyzed by independent readers; two observers evaluated the CT datasets for the presence of coronary artery stenosis > 50% and allograft vasculopathy. Results: The sensitivity for detecting > 50% luminal stenosis was 80-88% and specificity, 98-99% and for detection of cardiac allograft vasculopathy, the sensitivity was 91-96% and specificity, 88-91%. Conclusion: In this preliminary series, our results indicate that MDCT coronary angiography was capable of detecting both significant coronary stenosis as well as diffuse intimal proliferation. This non-invasive procedure could be an alternative to CA and IVUS in the surveillance of heart transplant patients. (authors) [es

  13. Joint learning of ultrasonic backscattering statistical physics and signal confidence primal for characterizing atherosclerotic plaques using intravascular ultrasound.

    Science.gov (United States)

    Sheet, Debdoot; Karamalis, Athanasios; Eslami, Abouzar; Noël, Peter; Chatterjee, Jyotirmoy; Ray, Ajoy K; Laine, Andrew F; Carlier, Stephane G; Navab, Nassir; Katouzian, Amin

    2014-01-01

    Intravascular Ultrasound (IVUS) is a predominant imaging modality in interventional cardiology. It provides real-time cross-sectional images of arteries and assists clinicians to infer about atherosclerotic plaques composition. These plaques are heterogeneous in nature and constitute fibrous tissue, lipid deposits and calcifications. Each of these tissues backscatter ultrasonic pulses and are associated with a characteristic intensity in B-mode IVUS image. However, clinicians are challenged when colocated heterogeneous tissue backscatter mixed signals appearing as non-unique intensity patterns in B-mode IVUS image. Tissue characterization algorithms have been developed to assist clinicians to identify such heterogeneous tissues and assess plaque vulnerability. In this paper, we propose a novel technique coined as Stochastic Driven Histology (SDH) that is able to provide information about co-located heterogeneous tissues. It employs learning of tissue specific ultrasonic backscattering statistical physics and signal confidence primal from labeled data for predicting heterogeneous tissue composition in plaques. We employ a random forest for the purpose of learning such a primal using sparsely labeled and noisy samples. In clinical deployment, the posterior prediction of different lesions constituting the plaque is estimated. Folded cross-validation experiments have been performed with 53 plaques indicating high concurrence with traditional tissue histology. On the wider horizon, this framework enables learning of tissue-energy interaction statistical physics and can be leveraged for promising clinical applications requiring tissue characterization beyond the application demonstrated in this paper. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Angiographically borderline left main coronary artery lesions: correlation of transthoracic doppler echocardiography and intravascular ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Varga Albert

    2011-06-01

    Full Text Available Abstract Background the clinical decision making could be difficult in patients with borderline lesions (visually assessed stenosis severity of 30 to 50% of the left main coronary artery (LM. The aim of the study was to evaluate the relationship between transthoracic Doppler (TTDE peak diastolic flow velocity (PDV and intravascular ultrasound (IVUS measurements in the assessment of angiographically borderline LM lesions. Methods 27 patients (mean age 64 ± 8 years, 21 males with borderline LM stenosis referred for IVUS examination were included in the study. We performed standard IVUS with minimal lumen area (MLA and plaque burden (PB measurement and routine quantitative coronary angiography (QCA with diameter stenosis (%DS and area stenosis (%AS assessment in all. During TTDE, resting PDV was measured in the LM. Results interpretable Doppler signal could be obtained in 24 patients (88% feasibility; therefore these patients entered the final analysis. MLA was 7.1 ± 2.7 mm2. TTDE measured PDV correlated significantly with IVUS-derived MLA (r = -0.46, p 2 LM stenosis. Conclusion In angiographically borderline LM disease, resting PDV from transthoracic echocardiography is increased in presence of increased plaque burden by IVUS. TTDE evaluation might be a useful adjunct to other invasive and non-invasive methods in the assessment of borderline LM lesions. Further, large scale studies are needed to establish the exact cut-off value of PDV for routine clinical application.

  15. Diagnostic accuracy of integrated intravascular ultrasound and optical coherence tomography (IVUS-OCT) system for coronary plaque characterization

    Science.gov (United States)

    Li, Jiawen; Ma, Teng; Mohar, Dilbahar; Correa, Adrian; Minami, Hataka; Jing, Joseph; Zhou, Qifa; Patel, Pranav M.; Chen, Zhongping

    2014-03-01

    Intravascular ultrasound (IVUS) imaging and optical coherence tomography (OCT), two commonly used intracoronary imaging modalities, play important roles in plaque evaluation. The combined use of IVUS (to visualize the entire plaque volume) and OCT (to quantify the thickness of the plaque cap, if any) is hypothesized to increase plaque diagnostic accuracy. Our group has developed a fully-integrated dual-modality IVUS-OCT imaging system and 3.6F catheter for simultaneous IVUS-OCT imaging with a high resolution and deep penetration depth. However, the diagnostic accuracy of an integrated IVUS-OCT system has not been investigated. In this study, we imaged 175 coronary artery sites (241 regions of interest) from 20 cadavers using our previous reported integrated IVUS-OCT system. IVUS-OCT images were read by two skilled interventional cardiologists. Each region of interest was classified as either calcification, lipid pool or fibrosis. Comparing the diagnosis by cardiologists using IVUSOCT images with the diagnosis by the pathologist, we calculated the sensitivity and specificity for characterization of calcification, lipid pool or fibrosis with this integrated system. In vitro imaging of cadaver coronary specimens demonstrated the complementary nature of these two modalities for plaques classification. A higher accuracy was shown than using a single modality alone.

  16. Safety and efficacy of intravascular ultrasound-guided inferior vena cava filter in super obese bariatric patients.

    Science.gov (United States)

    Kardys, Clark M; Stoner, Michael C; Manwaring, Mark L; Barker, Michael; Macdonald, Kenneth G; Pender, John R; Chapman, William H

    2008-01-01

    The morbidly obese (body mass index >40 kg/m(2)) are at significant risk of postoperative venous thromboembolism (VTE). Pulmonary embolism is the leading cause of death after Roux-en-Y gastric bypass, approximating .5%. Because of the technical limitations with fluoroscopy and table weight limits, it has been our practice at our university-based bariatric center to offer intravascular ultrasound (IVUS)-guided inferior vena cava filter (IVCF) placement at Roux-en-Y gastric bypass to patients with a history of VTE, hypercoagulable state, or profound immobility. The hospital and outpatient records of all 594 patients who underwent Roux-en-Y gastric bypass from January 1, 2004 to October 31, 2006 were reviewed. The patients who had undergone concurrent IVUS-guided IVCF placement were selected. The co-morbidities, outcomes, and complications were recorded. Of the 594 patients, 31 (mean body mass index 71.2 +/- 2.96 kg/m(2)) had undergone concurrent IVUS-guided IVCF placement. The indications included a history of VTE (n = 5), a known hypercoagulable state (n = 2), and profound immobility (n = 25). The technical success rate was 96.8%. One filter was malpositioned in the iliac vein. No catheter site complications occurred. A ventilation/perfusion scan and computed tomography scan each detected pulmonary embolism in 2 surviving patients within 2 months postoperatively. Two patients died, 1 on postoperative day 8 and 1 on postoperative day 15 (6.4%). The mean follow-up time was 262.8 +/- 37.3 days. Autopsy excluded VTE or IVCF-related issues as the cause of death in both patients. These results suggest the efficacy of IVUS-guided IVCF placement in preventing mortality from pulmonary embolism in high-risk bariatric patients. IVUS-guided IVCF placement can be safely performed with an excellent success rate in high-risk patients who would not otherwise be candidates for intervention because of the technical limitations of fluoroscopy.

  17. A new method for real-time co-registration of 3D coronary angiography and intravascular ultrasound or optical coherence tomography

    International Nuclear Information System (INIS)

    Carlier, Stéphane; Didday, Rich; Slots, Tristan; Kayaert, Peter; Sonck, Jeroen; El-Mourad, Mike; Preumont, Nicolas; Schoors, Dany; Van Camp, Guy

    2014-01-01

    We present a new clinically practical method for online co-registration of 3D quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) or optical coherence tomography (OCT). The workflow is based on two modified commercially available software packages. Reconstruction steps are explained and compared to previously available methods. The feasibility for different clinical scenarios is illustrated. The co-registration appears accurate, robust and induced a minimal delay on the normal cath lab activities. This new method is based on the 3D angiographic reconstruction of the catheter path and does not require operator’s identification of landmarks to establish the image synchronization

  18. Intravascular ultrasound guidance improves clinical outcomes during implantation of both first- and second-generation drug-eluting stents: a meta-analysis.

    Science.gov (United States)

    Nerlekar, Nitesh; Cheshire, Caitlin J; Verma, Kunal P; Ihdayhid, Abdul-Rahman; McCormick, Liam M; Cameron, James D; Bennett, Martin R; Malaiapan, Yuvaraj; Meredith, Ian T; Brown, Adam J

    2017-01-20

    Our aim was to assess whether intravascular ultrasound (IVUS) improves clinical outcomes during implantation of first- and second-generation drug-eluting stents (DES). IVUS guidance is associated with improved clinical outcomes during DES implantation, but it is unknown whether this benefit is limited to either first- or second-generation devices. MEDLINE, EMBASE and PubMed were searched for studies comparing outcomes between IVUS- and angiography-guided PCI. Among 909 potentially relevant studies, 15 trials met the inclusion criteria. The primary endpoint was MACE, defined as death, myocardial infarction, target vessel/lesion revascularisation (TVR/TLR) or stent thrombosis (ST). Summary estimates were obtained using Peto modelling. In total, 9,313 patients from six randomised trials and nine observational studies were included. First-generation DES were implanted in 6,156 patients (3,064 IVUS-guided and 3,092 angiography-guided) and second-generation in 3,157 patients (1,528 IVUS-guided and 1,629 angiography-guided). IVUS guidance was associated with a significant reduction in MACE (odds ratio [OR] 0.73, 95% CI: 0.64-0.85, pDES (0.57, 95% CI: 0.43-0.77, pDES, IVUS guidance was associated with significantly lower rates of cardiac death (OR 0.33, 95% CI: 0.14-0.78, p=0.02), TVR (OR 0.47, 95% CI: 0.28-0.79, p=0.006), TLR (OR 0.61, 95% CI: 0.42-0.90, p=0.01) and ST (OR 0.31, 95% CI: 0.12-0.78, p=0.02). Cumulative meta-analysis highlighted progressive temporal benefit towards IVUS-guided PCI to reduce MACE (OR 0.60, 95% CI: 0.48-0.75, pDES platforms. These data support the use of IVUS guidance in contemporary revascularisation procedures using second-generation DES.

  19. Impact of statins on progression of atherosclerosis: rationale and design of SATURN (Study of Coronary Atheroma by InTravascular Ultrasound: effect of Rosuvastatin versus AtorvastatiN).

    Science.gov (United States)

    Nicholls, Stephen J; Borgman, Marilyn; Nissen, Steven E; Raichlen, Joel S; Ballantyne, Christie; Barter, Philip; Chapman, M John; Erbel, Raimund; Libby, Peter

    2011-06-01

    Previous imaging studies have demonstrated that the beneficial impact of high-dose statins on the progression of coronary atherosclerosis associates with their ability to lower levels of low-density lipoprotein cholesterol (LDL-C) and C-reactive protein (CRP) and to raise high-density lipoprotein cholesterol (HDL-C). The Study of Coronary Atheroma by InTravascular Ultrasound: Effect of Rosuvastatin versus AtorvastatiN (SATURN, NCT00620542) aims to compare the effects of high-dose atorvastatin and rosuvastatin on disease progression. A total of 1385 subjects with established coronary artery disease (CAD) on angiography were randomized to receive rosuvastatin 40 mg or atorvastatin 80 mg for 24 months. The primary efficacy parameter will be the nominal change in percent atheroma volume (PAV), determined by analysis of intravascular ultrasound (IVUS) images of matched coronary artery segments acquired at baseline and at 24-month follow-up. The effect of statin therapy on plasma lipids and inflammatory markers, and the incidence of clinical cardiovascular events will also be assessed. The study does not have the statistical power to directly compare the treatment groups with regard to clinical events. Serial IVUS has emerged as a sensitive imaging modality to assess the impact of treatments on arterial structure. In this study, IVUS will be used to determine whether high-dose statins have different effects on plaque progression.

  20. Results of the Intravascular Cooling in the Treatment of Acute Stroke 2 Trial (ICTuS-2)

    Science.gov (United States)

    Lyden, Patrick; Hemmen, Thomas; Grotta, James; Rapp, Karen; Ernstrom, Karin; Rzesiewicz, Teresa; Parker, Stephanie; Concha, Mauricio; Syed, Hussain; Agarwal, Sachin; Meyer, Brett; Jurf, Julie; Altafullah, Irfan; Raman, Rema

    2016-01-01

    Background and Purpose Therapeutic hypothermia (TH) is a potent neuroprotectant approved for cerebral protection after neonatal hypoxia-ischemia and cardiac arrest. TH for acute ischemic stroke is safe and feasible in pilot trials. We designed a study protocol to provide safer, faster TH in stroke patients. Methods Safety procedures and 4°C saline infusions for faster cooling were added to the Intravascular Cooling Treatment in Acute Stroke (ICTuS) trial protocol. A femoral venous intravascular cooling catheter following intravenous rt-PA in eligible patients provided 24 hours cooling followed by a 12 hour re-warm. Serial safety assessments and imaging were performed. The primary endpoint was 3-month modified Rankin score 0,1. Results Of the intended 1600 subjects, 120 were enrolled before the study was stopped. Randomly, 63 were to receive hypothermia (HY) plus anti-shivering treatment and 57 normothermia (NT). Compared to prior studies, cooling rates were improved with a cold saline bolus, without fluid overload. The intention-to-treat primary outcome of 90-day mRS 0,1 occurred in 33% HY and 38% NT subjects, OR (95% CL) of 0.81 (0.36, 1.85). Serious adverse events occurred equally. Mortality was 15.9% HY and 8.8% NT subjects, OR (95% CL) of 1.95 (0.56, 7.79). Pneumonia occurred in 19% HY vs. 10.5% in NT subjects, OR (95% CL) of 1.99 (0.63, 6.98). Conclusion Intravascular TH was confirmed to be safe and feasible in rt-PA treated acute ischemic stroke patients. Protocol changes designed to reduce pneumonia risk appeared to fail, although the sample is small. Clinical trial registration clinicaltrials.gov NCT 01123161. PMID:27834742

  1. PCA-based polling strategy in machine learning framework for coronary artery disease risk assessment in intravascular ultrasound: A link between carotid and coronary grayscale plaque morphology.

    Science.gov (United States)

    Araki, Tadashi; Ikeda, Nobutaka; Shukla, Devarshi; Jain, Pankaj K; Londhe, Narendra D; Shrivastava, Vimal K; Banchhor, Sumit K; Saba, Luca; Nicolaides, Andrew; Shafique, Shoaib; Laird, John R; Suri, Jasjit S

    2016-05-01

    Percutaneous coronary interventional procedures need advance planning prior to stenting or an endarterectomy. Cardiologists use intravascular ultrasound (IVUS) for screening, risk assessment and stratification of coronary artery disease (CAD). We hypothesize that plaque components are vulnerable to rupture due to plaque progression. Currently, there are no standard grayscale IVUS tools for risk assessment of plaque rupture. This paper presents a novel strategy for risk stratification based on plaque morphology embedded with principal component analysis (PCA) for plaque feature dimensionality reduction and dominant feature selection technique. The risk assessment utilizes 56 grayscale coronary features in a machine learning framework while linking information from carotid and coronary plaque burdens due to their common genetic makeup. This system consists of a machine learning paradigm which uses a support vector machine (SVM) combined with PCA for optimal and dominant coronary artery morphological feature extraction. Carotid artery proven intima-media thickness (cIMT) biomarker is adapted as a gold standard during the training phase of the machine learning system. For the performance evaluation, K-fold cross validation protocol is adapted with 20 trials per fold. For choosing the dominant features out of the 56 grayscale features, a polling strategy of PCA is adapted where the original value of the features is unaltered. Different protocols are designed for establishing the stability and reliability criteria of the coronary risk assessment system (cRAS). Using the PCA-based machine learning paradigm and cross-validation protocol, a classification accuracy of 98.43% (AUC 0.98) with K=10 folds using an SVM radial basis function (RBF) kernel was achieved. A reliability index of 97.32% and machine learning stability criteria of 5% were met for the cRAS. This is the first Computer aided design (CADx) system of its kind that is able to demonstrate the ability of coronary

  2. Severe thrombocytopenia induced by iodinated contrast after coronary angiography: The use of gadolinium contrast and intravascular ultrasound as an alternative to guide percutaneous coronary intervention.

    Science.gov (United States)

    Cubero-Gómez, José María; Guerrero Márquez, Francisco J; Diaz-de la-Llera, Luis; Fernández-Quero, Mónica; Guisado-Rasco, Agustín; Villa-Gil-Ortega, Manuel

    2017-01-01

    Acute contrast-induced thrombocytopenia is a rare event with the use of modern low osmolarity iodinated contrast media. The pathophysiological mechanism that causes platelet counts to drop has not been identified, but an immunological mechanism is suspected due to cytotoxicity after previous exposure to contrast. We report the case of a 47-year-old male patient with acute severe thrombocytopenia due to iodinated contrast media exposure. His platelet count after the procedure with the highest amount of contrast was zero, which is the lowest reported platelet count to date. Percutaneous coronary revascularization under both intravascular ultrasound and gadolinium contrast guidance was performed without complications. The most feared complication after the use of gadolinium is nephrogenic systemic fibrosis, especially in patients on hemodialysis. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Controlled antegrade intimal tracking with subintimal balloon inflation as a novel bailout technique for chronic total occlusion after failed intravascular ultrasound-guided parallel wire technique.

    Science.gov (United States)

    Imai, Yuta; Yajima, Junji; Hosaka, Fumitaka

    Failure to cross with a guidewire is the most common reason for failure of chronic total occlusion (CTO) percutaneous coronary intervention (PCI). In cases of CTO PCI with no interventional collaterals, an intravascular ultrasound (IVUS)-guided parallel wire technique is usually the last-resort procedure. Failure of this technique sometimes causes enlarged subintimal space, resulting in procedure failure. We present a successful second attempt at left anterior descending artery CTO PCI with no interventional collaterals. After IVUS-guided parallel wire technique failed with an enlarged subintimal space, successful antegrade wire crossing was achieved using controlled antegrade intimal tracking with balloon inflation in the subintimal space to deflect a second wire. This technique may be useful as a bailout strategy in otherwise-failed CTO PCI with an enlarged subintimal space. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Antiatherosclerotic effects of long-term maximally intensive statin therapy after acute coronary syndrome: insights from Study of Coronary Atheroma by Intravascular Ultrasound: Effect of Rosuvastatin Versus Atorvastatin.

    Science.gov (United States)

    Puri, Rishi; Nissen, Steven E; Shao, Mingyuan; Ballantyne, Christie M; Barter, Philip J; Chapman, M John; Erbel, Raimund; Libby, Peter; Raichlen, Joel S; Uno, Kiyoko; Kataoka, Yu; Nicholls, Stephen J

    2014-11-01

    Patients with acute coronary syndromes (ACS) display diffuse coronary atheroma instability and heightened risk of early and late recurrent coronary events. We compared the long-term antiatherosclerotic efficacy of high-intensity statins in patients with ACS when compared with stable disease. Study of Coronary Atheroma by Intravascular Ultrasound: Effect of Rosuvastatin Versus Atorvastatin (SATURN) used serial intravascular ultrasound measures of coronary atheroma volume in patients treated with rosuvastatin 40 mg or atorvastatin 80 mg for 24 months. The overall effect of high-intensity statins on the change in coronary percent atheroma volume and major adverse cardiovascular events (death/nonfatal myocardial infarction/coronary revascularization) were evaluated in this post hoc analysis. When compared with non-ACS patients (n=678), patients with ACS (n=361) were younger, actively smoking, and have had a previous myocardial infarction (all P<0.001). At baseline, patients with ACS exhibited lower high-density lipoprotein cholesterol (43.5±11 versus 45.8±11 mg/dL; P=0.002), a higher apolipoprotein B: apolipoprotein A-1 ratio (0.90±0.24 versus 0.83±0.24; P<0.001) and greater percent atheroma volume (37.3±8.5% versus 35.9±8.1%; P=0.01) when compared with non-ACS patients. Despite similar achieved levels of lipid and inflammatory markers after high-intensity statin therapy, patients with ACS demonstrated greater percent atheroma volume regression than non-ACS patients (-1.46±0.14 versus -0.89±0.13; P=0.003). After propensity-weighted multivariable adjustment, baseline percent atheroma volume (P<0.001) and an ACS clinical presentation (P=0.02) independently associated with plaque regression. The 24-month major adverse cardiovascular events-free survival was similar between patients with ACS and non-ACS (90.6 versus 92.9%; P=0.25). Long-term high-intensity statin therapy caused greater plaque regression and comparable major adverse cardiovascular events rates in

  5. Assessment of carotid plaque composition using fast-kV switching dual-energy CT with gemstone detector: comparison with extracorporeal and virtual histology-intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Shinohara, Yuki; Kuya, Keita; Ohta, Yasutoshi; Fujii, Shinya; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Yonago (Japan); Sakamoto, Makoto; Watanabe, Takashi [Tottori University, Division of Neurosurgery, Department of Neurological Sciences, Faculty of Medicine, Yonago (Japan); Kishimoto, Junichi; Iwata, Naoki [Tottori University Hospital, Division of Clinical Radiology, Yonago (Japan)

    2015-09-15

    The present study compares the applicability of CT carotid plaque imaging using effective Z maps using gemstone spectral imaging (GSI) with that of conventional extracorporeal carotid ultrasound (US) and virtual histology-intravascular ultrasound (VH-IVUS). We assessed stenosis in 31 carotid arteries of 30 patients. All patients underwent carotid CTA using GSI (Discovery CT750 HD, GE Healthcare). US and IVUS were examined with 25 and 8 vessels, respectively. We compared the effective Z values at noncalcified carotid plaque with the plaque components identified by US. We defined the plaque with low or low to iso intensity on US as vulnerable plaque and the plaque with iso, iso to high, and high intensity on US as stable plaque. We also performed visual assessment of color-coded effective Z maps in comparison with VH-IVUS and compared effective Z values with plaque components generated by VH-IVUS. The effective Z values at noncalcified carotid plaque were significantly lower for a group with vulnerable plaque, than with stable plaque on US (p < 0.05). Receiver operating curve analysis showed that AUC of effective Z values was 0.882 concerning the differentiation of these two groups on US. The interpretation of color-coded effective Z maps was essentially compatible with that of VH-IVUS for carotid plaque in all vessels. Effective Z values at noncalcified plaque showed significant negative correlation with the areas of fibro-fatty components generated by VH-IVUS (ρ = -0.874, p < 0.05). Effective Z maps generated by GSI can detect vulnerable carotid plaque materials. (orig.)

  6. Assessment of carotid plaque composition using fast-kV switching dual-energy CT with gemstone detector: comparison with extracorporeal and virtual histology-intravascular ultrasound

    International Nuclear Information System (INIS)

    Shinohara, Yuki; Kuya, Keita; Ohta, Yasutoshi; Fujii, Shinya; Ogawa, Toshihide; Sakamoto, Makoto; Watanabe, Takashi; Kishimoto, Junichi; Iwata, Naoki

    2015-01-01

    The present study compares the applicability of CT carotid plaque imaging using effective Z maps using gemstone spectral imaging (GSI) with that of conventional extracorporeal carotid ultrasound (US) and virtual histology-intravascular ultrasound (VH-IVUS). We assessed stenosis in 31 carotid arteries of 30 patients. All patients underwent carotid CTA using GSI (Discovery CT750 HD, GE Healthcare). US and IVUS were examined with 25 and 8 vessels, respectively. We compared the effective Z values at noncalcified carotid plaque with the plaque components identified by US. We defined the plaque with low or low to iso intensity on US as vulnerable plaque and the plaque with iso, iso to high, and high intensity on US as stable plaque. We also performed visual assessment of color-coded effective Z maps in comparison with VH-IVUS and compared effective Z values with plaque components generated by VH-IVUS. The effective Z values at noncalcified carotid plaque were significantly lower for a group with vulnerable plaque, than with stable plaque on US (p < 0.05). Receiver operating curve analysis showed that AUC of effective Z values was 0.882 concerning the differentiation of these two groups on US. The interpretation of color-coded effective Z maps was essentially compatible with that of VH-IVUS for carotid plaque in all vessels. Effective Z values at noncalcified plaque showed significant negative correlation with the areas of fibro-fatty components generated by VH-IVUS (ρ = -0.874, p < 0.05). Effective Z maps generated by GSI can detect vulnerable carotid plaque materials. (orig.)

  7. Acute myocardial infarction due to spontaneous, localized, acute dissection of the sinus of Valsalva detected by intravascular ultrasound and electrocardiogram-gated computed tomography.

    Science.gov (United States)

    Ichihashi, Taku; Ito, Tsuyoshi; Murai, Shunsuke; Ikehara, Noriyuki; Fujita, Hiroshi; Suda, Hisao; Ohte, Nobuyuki

    2016-09-01

    A 58-year-old man was referred to our hospital because of chest pain. The 12-lead electrocardiogram (ECG) revealed ST-segment elevation in II, III, and a Vf with advanced heart block. Transthoracic echocardiography demonstrated aortic root dilatation at the sinus of Valsalva, moderate aortic regurgitation, and decreased wall motion in the inferior part of the left ventricle. Non-ECG-gated enhanced computed tomography (CT) did not reveal an aortic dissection. The patient underwent emergent coronary angiography, which revealed a severely narrowed ostium of the right coronary artery (RCA). Percutaneous coronary intervention (PCI) was performed under intravascular ultrasound (IVUS) guidance. IVUS images demonstrated an intimal flap extending from the aortic wall to the proximal RCA, suggesting that a periaortic hematoma in the false lumen compressed the ostium of the RCA, leading to acute myocardial infarction. To recover hemodynamic stability, the RCA ostium was stented. Subsequent ECG-gated enhanced CT clearly depicted the entry point and extension of the dissection localized within the sinus of Valsalva. The dissection likely involved the left main coronary artery and an emergent Bentall procedure was performed. Intraoperative findings confirmed an intimal tear and extension of the dissection. Thus, ECG-gated CT can clearly depict the entry site and extension of a dissection occurring in the localized area that cannot be detected by conventional CT.

  8. Early characterization of atherosclerotic coronary plaques with multidetector computed tomography in patients with acute coronary syndrome. A comparative study with intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Iriart, Xavier; Dos-Santos, Pierre [Universite Bordeaux 2, Inserm U. 441 Atherosclerose, Bordeaux (France); Brunot, Sebastien [CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Unite de Soins Intensifs Cardiologiques, Pessac (France); Unite d' Imagerie Thoracique et Cardiovasculaire, Hopital Cardiologique, Pessac (France); Coste, Pierre; Leroux, Lionel [Universite Bordeaux 2, Inserm U. 441 Atherosclerose, Bordeaux (France); Unite de Soins Intensifs Cardiologiques, Pessac (France); Montaudon, Michel [Universite Bordeaux 2, Inserm U. 885 F 33076, Bordeaux (France); CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Labeque, Jean-Noel; Jais, Catherine [Unite de Soins Intensifs Cardiologiques, Pessac (France); Laurent, Francois [Universite Bordeaux 2, Inserm U. 885 F 33076, Bordeaux (France); CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Unite d' Imagerie Thoracique et Cardiovasculaire, Hopital Cardiologique, Pessac (France)

    2007-10-15

    We compared 16-slice computed tomography (CT) with intravascular ultrasound (IVUS) in their ability to identify the culprit lesion, and to assess plaque characterization and vascular remodelling in acute coronary syndrome (ACS). Twenty patients were prospectively studied. Coronary plaque identification and characterization were compared using 16-slice CT and 40-MHz catheter-based IVUS. Minimum lumen area (MLA), cross-sectional vessel area (CVA) and vessel remodelling were determined for each comparable lesion. One hundred and sixty-nine segments were compared and 84 plaques analysed. Sixteen-slice CT detected 95% of culprit lesions (19/20). No feature suggestive of plaque rupture was detected by 16-slice CT. Attenuation measurements within all lesions revealed different values for hypoechoic (38 {+-} 33 HU), hyperechoic (94 {+-} 44 HU), and calcified plaques (561 {+-} 216 HU), (P < 0.001). Agreement between 16-slice CT and IVUS on measuring MLA and CVA was evaluated using Bland-Altman analysis. Pearson and intra-class coefficient (ICC) were 0.81 and 0.70 for MLA, and 0.81 and 0.36 for CVA, for 16-slice CT and IVUS, respectively. Agreement between both techniques for vessel positive remodelling was moderate (kappa = 0.54, P < 0.001). Sixteen-slice CT has shown moderate accuracy in quantifying and characterizing coronary plaques compared with IVUS. Spatial resolution of 16-slice CT remains a major limitation, however, to accurately assess the complex lesions involved in ACS. (orig.)

  9. Comprehensive analysis of intravascular ultrasound and angiographic morphology of culprit lesions between ST-segment elevation myocardial infarction and non-ST-segment elevation acute coronary syndrome.

    Science.gov (United States)

    Takaoka, Naoko; Tsujita, Kenichi; Kaikita, Koichi; Hokimoto, Seiji; Mizobe, Michio; Nagano, Masahide; Horio, Eiji; Sato, Koji; Nakayama, Naoki; Yoshimura, Hiromi; Yamanaga, Kenshi; Komura, Naohiro; Kojima, Sunao; Tayama, Shinji; Nakamura, Sunao; Ogawa, Hisao

    2014-02-15

    Some plaques lead to ST-segment elevation myocardial infarction (STEMI), whereas others cause non-ST-segment elevation acute coronary syndrome (NSTEACS). We used angiography and intravascular ultrasound (IVUS) to investigate the difference of culprit lesion morphologies in ACS. Consecutive 158 ACS patients whose culprit lesions were imaged by preintervention IVUS were enrolled (STEMI=81; NSTEACS=77). IVUS and angiographic findings of the culprit lesions, and clinical characteristics were compared between the groups. There were no significant differences in patients' characteristics except for lower rate of statin use in patients with STEMI (20% vs 44%, p=0.001). Although angiographic complex culprit morphology (Ambrose classification) and thrombus were more common in STEMI than in NSTEACS (84% vs 62%, p=0.002; 51% vs 5%, pSYNTAX score was lower in STEMI (8.6 ± 5.4 vs 11.5 ± 7.1, p=0.01). In patients with STEMI, culprit echogenicity was more hypoechoic (64% vs 40%, p=0.01), and the incidence of plaque rupture, attenuation and "microcalcification" were significantly higher (56% vs 17%, pMorphological feature (outward vessel remodeling, plaque buildup and IVUS vulnerability of culprit lesions) might relate to clinical presentation in patients with ACS. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients.

    Science.gov (United States)

    Shin, Dong-Ho; Hong, Sung-Jin; Mintz, Gary S; Kim, Jung-Sun; Kim, Byeong-Keuk; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong-Ki

    2016-11-14

    The aim of this study was to evaluate the clinical usefulness of intravascular ultrasound (IVUS)-guided new-generation drug-eluting stent (DES) implantation using a meta-analysis of individual patient-level data from randomized trials. Published randomized trials that compare IVUS-guided versus angiography-guided new-generation DES implantation are scarce. Searches of the MEDLINE, Embase, and Cochrane databases were performed to find randomized trials that compared IVUS-guided versus angiography-guided new-generation DES implantation. A total of 2,345 patients from 3 randomized trials were identified, and all patients were treated for long lesions or chronic total occlusions. Individual patient-level data were obtained. The primary endpoint was a major adverse cardiac event, a composite of cardiac death, myocardial infarction, or stent thrombosis. An intention-to-treat analysis and per protocol analysis were performed. By 1 year post-procedure, major adverse cardiac events had occurred in 0.4% of the patients who underwent IVUS-guided DES implantation versus 1.2% of those who underwent angiography-guided DES implantation (hazard ratio [HR]: 0.36; 95% confidence interval [CI]: 0.13 to 0.99; p = 0.040). For the IVUS-guided group, favorable clinical outcomes were observed for myocardial infarction (0% vs. 0.4%; HR: 0.09; p = 0.026). In addition, the clinical benefit of IVUS guidance was stronger in the per protocol analysis (HR: 0.32; 95% CI: 0.12 to 0.89; p = 0.021). Compared with angiographic guidance, IVUS-guided new-generation DES implantation was associated with favorable outcomes in terms of major adverse cardiac events, the composite of cardiac death, myocardial infarction, or stent thrombosis. These findings must be interpreted only for complex lesions, because all identified patients had long lesions or chronic total occlusions. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Maintenance of normothermia during burn surgery with an intravascular temperature control system: a non-randomised controlled trial.

    Science.gov (United States)

    Prunet, Bertrand; Asencio, Yves; Lacroix, Guillaume; Bordes, Julien; Montcriol, Ambroise; D'Aranda, Erwan; Pradier, Jean-Philippe; Dantzer, Eric; Meaudre, Eric; Goutorbe, Philippe; Kaiser, Eric

    2012-05-01

    Hypothermia remains one of the major factors limiting surgery in extensively burned patients. We evaluated the effectiveness of an intravascular rewarming technique using CoolGard 3000™ system and Icy™ catheter to maintain normothermia during surgeries of severe burned patients and compared these findings to a historical control group. This was a controlled non-randomised trial conducted between March 2008 and August 2009. Patients with burns greater than or equal to 40% of the total body surface area were included. Before the first burn excision, the Icy™ catheter was placed in the inferior vena cava via the femoral vein. Warming was then initiated and maintained until the bladder temperature reached over 37.5°C. The bladder temperature was recorded every 30min during surgery and for the first hour post-operatively and compared to a historical control group. We enrolled 4 patients and 11 surgeries in the CoolGard™ group and compared them to 3 patients and 10 surgeries in the historical cohort. All intraoperative bladder temperatures from T=30 were statistically different in the two groups. In the CoolGard™ group, no patient became hypothermic and no surgery was aborted because the patient's temperature had rapidly fallen below the threshold temperature (35.5°C). No device-related complication was reported. The use of an intravenous warming catheter is a novel approach to maintain normothermia during surgery in burn victims and may be more effective than traditional methods. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. The use of intravascular ultrasound imaging to improve use of inferior vena cava filters in a high-risk bariatric population.

    Science.gov (United States)

    Kardys, Clark M; Stoner, Michael C; Manwaring, Mark L; Bogey, William M; Parker, Frank M; Powell, Steve

    2007-12-01

    Pulmonary embolism is the leading cause of death after gastric bypass procedures for obesity, approximating 0.5% to 4%. All bariatric patients, but especially the super-obese, which have a body mass index (BMI) >50 kg/m(2), are at significant risk for postoperative venous thromboembolism (VTE). Visualization and weight limitations of fluoroscopy tables exclude most bariatric and all super-obese patients from inferior vena cava (IVC) filter placement using fluoroscopy. Intravascular ultrasound (IVUS)-guided IVC filter placement is the only modality that allows these high-risk patients to have an IVC filter placed. Hospital and outpatient records of the 494 patients who underwent gastric bypass procedures from January 1, 2004, to May 31, 2006, were reviewed. All patients who had concurrent IVC filter placement with the use of IVUS guidance were selected. Comorbidities, outcomes, and complications were recorded. We identified 27 patients with mean BMI of 70 +/- 3 kg/m(2); of these, 25 were super-obese (BMI >50 kg/m(2)). Procedures included five laparoscopic and 22 open gastric bypass operations. All patients underwent concurrent IVC filter placement using IVUS guidance. In addition to super-obesity, indications for IVC filter placement included history of VTE (n = 4), known hypercoagulable state (n = 2), and profound immobility (n = 21). Mean follow up was 293 +/- 40 days. Technical success rate was 96.3%. There were no catheter site complications. In one surviving patient, a nonfatal pulmonary embolism was detected by computed tomography 2 months postoperatively. Two patients died, and autopsy excluded VTE as the cause of death in both. This study suggests efficacy of IVUS-guided IVC filter placement in preventing mortality from pulmonary embolism in high-risk bariatric patients, including the super-obese. IVUS-guided IVC filter placement can be safely performed with an excellent success rate in all bariatric patients, including the super-obese, who otherwise would

  13. Circulating Microparticles and Coronary Plaque Components Assessed by Virtual Histology Intravascular Ultrasound of the Target Lesion in Patients with Stable Angina.

    Directory of Open Access Journals (Sweden)

    Pil-Ki Min

    Full Text Available High levels of microparticles (MPs circulate in the blood of patients with atherosclerotic diseases where they can serve as potential biomarkers of vascular injury and cardiovascular outcome. We used virtual histology intravascular ultrasound (VH-IVUS to evaluate the relationship between the levels of circulating MPs and the coronary plaque composition in patients with stable angina. We included 35 patients with stable angina (22 men, age 64 ± 9 years and a de novo target lesion. Preintervention gray-scale and VH-IVUS analysis was performed across the target lesion. Volumetric analysis was performed over a 10-mm-long segment centered at the minimum luminal site. Blood samples were obtained from the femoral artery before coronary angioplasty. MPs were measured using a solid-phase capture assay from a commercial kit. We divided participants into either a low MPs group or high MPs group based on the median value of MPs. There was no significant difference in baseline characteristics between the groups. The plaque burden and remodeling index were similar between the groups. The presence of VH-IVUS-derived thin-cap fibroatheroma was not different between the groups. The percentage of the necrotic core (NC was significantly higher in the high MPs group than in the low MPs group, both in planar (17.0 ± 8.8% vs. 24.1 ± 6.9%, p = 0.012 and volumetric analyses (17.0 ± 4.8% vs. 22.1 ± 4.3%, p = 0.002. Circulating MPs were positively correlated with the percentage of the NC area at the minimal luminal site (r = 0.491, p = 0.003 and the percentage of the NC volume (r = 0.496, p = 0.002. Elevated levels of circulating MPs were associated with the amount of NC in the target lesion in those with stable angina, suggesting a potential role of circulating MPs as a biomarker for detecting unstable plaque in patients with stable angina.

  14. Ultrasound-guided cryoablation of breast fibroadenoma: a pilot trial.

    Science.gov (United States)

    Golatta, Michael; Harcos, Aba; Pavlista, David; Danes, Jan; Klein, Rafi; Simovich, Paola; Gruber, Ines; Hahn, Markus

    2015-06-01

    The aim of the study was to evaluate cryoablation (CA) under ultrasound guidance in the office setting with liquid nitrogen system for patients with fibroadenoma (FA). For this prospective multicenter trial, an office-based cryosurgical system was used to treat histological confirmed benign FA with a maximum dimension of 3 cm. Sixty CA procedures were performed under ultrasound guidance. A freeze-thaw-freeze treatment cycle was performed according to the size of the FA. During the CA procedure continuous ultrasound monitoring was performed, verifying engulfment of the FA. Patients attended four follow-up visits at 1 week, 3, 6 months and 1 year and underwent ultrasound, physical examination and photography. Data were collected and analyzed in 60 cases. 59 of 60 FA (98 %) were fully engulfed by the ice ball. No serious adverse events occurred related to the IceSense3 system. At the 1-year follow-up, the FAs were gone in 93% of the cases. Prior to CA procedure, 76% of the FAs were palpable. Afterwards in some cases (22%), a scar/cryo lesion was palpable. 28% of the patients reported pain, described as mild or moderate, compared to 2% after 1 year. Cosmetic results at 12 months follow-up were reported as good or excellent in 100% by physician and in 97% by patients. The cryodestruction of the FA using liquid nitrogen system proved functional and safe, while showing meaningful reduction in volume, palpability, pain and cosmetic satisfying outcomes.

  15. A new method to quantify coronary calcification by intravascular ultrasound - the different patterns of calcification of acute myocardial infarction, unstable angina pectoris and stable angina pectoris.

    Science.gov (United States)

    Wang, Xiaofei; Lu, Chengzhi; Chen, Xin; Zhao, Xiangdong; Xia, Dasheng

    2008-11-01

    Intravascular ultrasound (IVUS) enables the identification of calcification with more details and quantification of calcification, but there is not a proper method to quantify the calcification with IVUS. Previous IVUS studies used arc or length of calcium, respectively, to quantify calcification, but calcium is determined by a combination of arc and length. We devised a new method to quantify calcium as arc area (AA) in the present study, and AA is two-dimensional and irrelevant to vessel size. We selected 201 patients with stable angina pectoris (SAP), unstable angina pectoris (UAP), or acute myocardial infarction (AMI) who underwent IVUS imaging of a de novo native atherosclerotic lesion considered to be the culprit lesion before percutaneous coronary intervention between December 2001 and December 2007. The culprit lesion site for analysis was the 10 mm-long segment including the smallest lumen cross-sectional area. The arc of each calcium deposit in each image was measured with a protractor centered on the lumen and the length of each calcium deposit was calculated with the number of images containing the calcium deposit minus 1, then multiplying 0.5 mm (the images were 0.5 mm apart). Finally, the AA was calculated by arc (degree) multiplying length (mm). The average number of calcium deposits in the culprit lesions of patients with acute myocardial infarction (AMI) was significantly larger than patients with SAP or UAP, and the number of calcium deposits of patients with SAP or UAP was almost the same (mean +/- SD, AMI 2.21 +/- 1.98, SAP 1.15 +/- 1.01, UAP 1.20 +/- 1.15, AMI versus SAP or UAP; p < 0.0005). The average AA per calcium deposit was significantly different in culprit lesions of patients with SAP and UAP or AMI, the calcium deposits were bigger in SAP than in UAP or AMI, and there were no differences between UAP and AMI (mean +/- SD, SAP 788.6 +/- 767.0 degree x mm, UAP 136.6 +/- 189.3 degree x mm, AMI 148.4 +/- 217.1 degree x mm, SAP versus UAP or

  16. Absence of accelerated atherosclerotic disease progression after intracoronary infusion of bone marrow derived mononuclear cells in patients with acute myocardial infarction--angiographic and intravascular ultrasound--results from the TErapia Celular Aplicada al Miocardio Pilot study.

    Science.gov (United States)

    Arnold, Roman; Villa, Adolfo; Gutiérrez, Hipólito; Sánchez, Pedro L; Gimeno, Federico; Fernández, Maria E; Gutiérrez, Oliver; Mota, Pedro; Sánchez, Ana; García-Frade, Javier; Fernández-Avilés, Francisco; San Román, Jose A

    2010-06-01

    We tried to evaluate a putative negative effect on coronary atherosclerosis in patients receiving intracoronary infusion of unfractionated bone marrow mononuclear cells (BMMC) following an acute ST-elevation myocardial infarction. Peripheral blood mononuclear cells or enriched CD133(+) BMMC have been associated with accelerated atherosclerosis of the distal segment of the infarct related artery (IRA). Thirty-seven patients with ST-elevation myocardial infarction from the TECAM pilot study underwent intracoronary infusion of autologous BMMC 9 +/- 3.1 days after onset of symptoms. We compared angiographic changes from baseline to 9 months of follow-up in the distal non-stented segment of the IRA, as well as in the contralateral coronary artery, with a matched control group. A subgroup of 15 treated patients underwent additional IVUS within the distal segment of the IRA. No difference between stem cell and control group were found regarding changes in minimum lumen diameter (0.006 +/- 0.42 vs 0.06 +/- 0.41 mm, P = ns) and the percentage of stenosis (-2.68 +/- 12.33% vs -1.78 +/- 8.75%, P = ns) at follow-up. Likewise, no differences were seen regarding changes in the contralateral artery (minimum lumen diameter -0.004 +/- 0.54 mm vs -0.06 +/- 0.35 mm, P = ns). In the intravascular ultrasound substudy, no changes were demonstrated comparing baseline versus follow-up in maximum area stenosis and plaque volume. In this pilot study, analysis of a subgroup of patients found that intracoronary injection of unfractionated BMMC in patients with acute ST-elevation myocardial infarction was not associated with accelerated atherosclerosis progression at mid term. Prospective, randomised studies in large cohorts with long-term angiographic and intravascular ultrasound follow-up are necessary to determine the safety of this therapy. Copyright 2010 Mosby, Inc. All rights reserved.

  17. Comparison of change in coronary atherosclerosis in patients with stable versus unstable angina pectoris receiving statin therapy (from the Treatment With Statin on Atheroma Regression Evaluated by Intravascular Ultrasound With Virtual Histology [TRUTH] study).

    Science.gov (United States)

    Nozue, Tsuyoshi; Yamamoto, Shingo; Tohyama, Shinichi; Fukui, Kazuki; Umezawa, Shigeo; Onishi, Yuko; Kunishima, Tomoyuki; Sato, Akira; Nozato, Toshihiro; Miyake, Shogo; Takeyama, Youichi; Morino, Yoshihiro; Yamauchi, Takao; Muramatsu, Toshiya; Hibi, Kiyoshi; Terashima, Mitsuyasu; Michishita, Ichiro

    2013-04-01

    Although statin-induced regression in coronary atherosclerosis seems to be greater in patients with acute coronary syndrome than in those with stable coronary artery disease, no reports have examined this. The purpose of the present study was to compare the changes in coronary atherosclerosis in patients with stable versus unstable angina pectoris (AP). The effects of 8-month statin therapy on coronary atherosclerosis were evaluated using virtual histology intravascular ultrasound, and analyzable intravascular ultrasound data were obtained from 119 patients (83 patients with stable AP and 36 with unstable AP). A significant decrease in plaque volume was observed in patients with unstable AP (-2.2%, p = 0.02) but not in patients with stable AP. A significant increase in the necrotic-core component (0.30 mm(3)/mm, p = 0.009) was observed only in patients with unstable AP. Significant positive correlations were observed between the percentage of change in platelet-activating factor acetylhydrolase and the percentage of change in plaque volume (r = 0.346, p = 0.05) in patients with unstable AP. No significant correlations were observed in patients with stable AP. Multivariate regression analyses showed that a reduction in platelet-activating factor acetylhydrolase was associated with regression in coronary atherosclerosis, particularly of the fibrous component (β = 0.443, p = 0.003), in patients with unstable AP. In conclusion, regression of the coronary artery plaque volume was greater, although statin therapy did not halt the increases in plaque vulnerability, in patients with unstable AP compared to those with stable AP. A reduction in the serum platelet-activating factor acetylhydrolase level was associated with regression in coronary atherosclerosis, particularly the fibrous plaque volume, in patients with unstable AP. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Impact of kissing balloon inflation on the main vessel stent volume, area, and symmetry after side-branch dilation in patients with coronary bifurcation lesions: a serial volumetric intravascular ultrasound study.

    Science.gov (United States)

    Rahman, Shahid; Leesar, Tara; Cilingiroglu, Mehmet; Effat, Mohamed; Arif, Imran; Helmy, Tarek; Leesar, Massoud A

    2013-09-01

    Intravascular ultrasound (IVUS) was performed to investigate the impact of kissing balloon inflation (KBI) on the main vessel (MV) stent volume, area, and symmetry after side-branch (SB) dilation in patients with coronary bifurcation lesions (CBL). It remains controversial whether KBI would restore the MV stent area and symmetry loss after SB dilation. A total of 88 serial IVUS examinations of the MV were performed after MV angioplasty, MV stenting, SB dilation, and KBI in 22 patients with CBL. The MV stent was divided into proximal, bifurcation, and distal segments; the stent volume index (SVI), minimal stent area (MSA), stent symmetry index (SSI), and external elastic membrane (EEM) volume index were measured in 198 stent segments and compared after MV stenting, SB dilation, and KBI. In the bifurcation segment, SVI, MSA, and SSI were significantly smaller after SB dilation than after MV stenting and KBI (SVI was 6.10 ± 1.50 mm(3)/mm vs. 6.68 ± 1.60 mm(3)/mm and 6.57 ± 1.60 mm(3)/mm, respectively, p impact on the MV stent volume or symmetry. This is the first comprehensive volumetric IVUS analysis of CBL, to our knowledge, demonstrating that KBI restores the MV stent volume, area, and symmetry loss after SB dilation in the bifurcation segment, and induces asymmetric stent expansion in the proximal segment. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Serial intravascular ultrasound analysis of peri-stent remodeling and proximal and distal edge effects after sirolimus-eluting or paclitaxel-eluting stent implantation in patients with diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Mintz, Gary S

    2009-01-01

    Patients with diabetes have an increased risk of in-stent restenosis after coronary stent implantation. Serial intravascular ultrasound was used to study chronic arterial responses and edge effects after implantation of Cypher (Cordis, Johnson & Johnson, Miami Lakes, Florida) or Taxus (Boston......-up. The increase in peri-stent external elastic membrane (EEM) volume was more pronounced in the Taxus group (292.4 +/- 132.6 to 309.5 +/- 146.8 mm(3)) than in the Cypher group (274.4 +/- 137.2 to 275.4 +/- 140.1 mm(3); p = 0.005). Peri-stent plaque volume increased in the Taxus group (152.5 +/- 73.7 to 166.......1 +/- 85.1 mm(3)), but was unchanged in the Cypher group (153.5 +/- 75.5 to 151.5 +/- 75.8 mm(3); p = 0.002). In proximal and distal reference segments, mean lumen area decreased within the entire 5-mm edge segment (proximal and distal) because of plaque progression (distal, 5.5 +/- 3.6 to 5.8 +/- 3.7 mm(2...

  20. Characterization and morphology of atherosclerotic plaque of coronary arteries: utility of electron-beam tomography to detect non-calcified plaque: a comparison with conventional coronary angiography and intravascular ultrasound.

    Science.gov (United States)

    Funabashi, Nobusada; Misumi, Kazuo; Ohnishi, Hiroyuki; Asano, Miki; Komuro, Issei

    2007-01-31

    Electron-beam tomography (EBT) may provide useful information about characterization and morphology of atherosclerotic plaque of coronary arteries. Twenty-six subjects (20 male, 6 female) with suspected coronary heart disease had two routine (r) and one enhanced (e) EBT scans to detect non-calcified plaque (NCP) in the coronary arterial lumen, and were compared with conventional coronary angiograms (CAG) and intravascular ultrasound (IVUS). Three had the sites, which did not have high CT values suggesting calcification in rEBT, nor which was not enhanced by contrast material in eEBT. One had the site with positive CT values that were supposed to be the proliferation intima or organized thrombus and at the corresponding site mixed plaque was observed in the IVUS image. The other two had the site with negative CT values that were supposed to be fat tissue with significant stenosis in CAG. We also made the cross-sectional images of the vessel and the morphology of the NCP, which projected into the lumen, could be evaluated. We could detect the NCP, differentiate fat tissue from soft tissue and evaluate the morphology of the plaque in EBT.

  1. Ultrasound

    Science.gov (United States)

    Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two-dimensional image of the baby while inside the mother's ...

  2. Intravascular pulmonary metastases

    International Nuclear Information System (INIS)

    Shepard, J.A.O.; Moore, E.H.; Templeton, P.A.; McLoud, T.C.

    1988-01-01

    The diagnosis of intravascular metastatic tumor emboli to the lungs is rarely made. The authors present a characteristic radiographic finding of intravascular lung metastases that they observed in four patients with diagnoses or right atrial myoxoma, invasive renal cell carcinoma, invasive pelvic osteosarcoma, and recurrent pelvic chondrosarcoma. Substantiation of intravascular pulmonary metastases was achieved by means of autopsy, pulmonary artery biopsy, and surgical documentation of tumor invasion of the inferior vena cava or pelvic veins. In all four cases, chest computed tomography (CT) demonstrated branching, beaded opacities extending from the hila into the periphery of the lung in the distribution of pulmonary arteries. In one case, similar findings were observed in magnetic resonance (MR) images of the chest. Follow-up studies in three cases showed progressive enlargement and varicosity of the abnormal pulmonary artery consistent with proliferation of intravascular tumor. In the case of metastatic osteosarcoma, intraluminal ossification was also observed at CT. In three of four cases, pulmonary infarction was demonstrated in the distribution of the abnormal pulmonary arteries seen at CT as small, peripheral, wedge-shaped opacities. The demonstration of progressively dilated and beaded pulmonary arteries in patients with extrathoracic malignancies is suggestive of intravascular lung metastases, particularly when accompanied by peripheral infarction

  3. Intravascular photoacoustic imaging of human coronary atherosclerosis

    Science.gov (United States)

    Jansen, Krista; van der Steen, Antonius F. W.; Springeling, Geert; van Beusekom, Heleen M. M.; Oosterhuis, J. Wolter; van Soest, Gijs

    2011-03-01

    We demonstrate intravascular photoacoustic imaging of human coronary atherosclerotic plaque. We specifically imaged lipid content, a key factor in vulnerable plaques that may lead to myocardial infarction. An integrated intravascular photoacoustics (IVPA) and ultrasound (IVUS) catheter with an outer diameter of 1.25 mm was developed. The catheter comprises an angle-polished optical fiber adjacent to a 30 MHz single-element transducer. The ultrasonic transducer was optically isolated to eliminate artifacts in the PA image. We performed measurements on a cylindrical vessel phantom and isolated point targets to demonstrate its imaging performance. Axial and lateral point spread function widths were 110 μm and 550 μm, respectively, for PA and 89 μm and 420 μm for US. We imaged two fresh human coronary arteries, showing different stages of disease, ex vivo. Specific photoacoustic imaging of lipid content, is achieved by spectroscopic imaging at different wavelengths between 1180 and 1230 nm.

  4. Dosimetric model for intravascular brachytherapy

    International Nuclear Information System (INIS)

    Flower, E.E.; Stroud, D.B.

    2000-01-01

    Full text: Intravascular brachytherapy has been shown to be a prophylaxis for restenosis. Adventitial macrophages, which are extremely radiosensitive, initiate neointima formation. A model of the dose levels of the treatment range is developed, assuming that the adventitia is the target tissue. If the adventitia receives a dose of less than 10 Gy, it is assumed the treatment will be ineffective. If the dose to any part of the wall is above 30 Gy, it is assumed that the treatment could be detrimental. Hence the treatment range is between 10 and 30 Gy, with 20 Gy being the optimum dosage to the adventitia. An algorithm using numerical integration of published dose kernels calculates the dose at any point surrounding a beta ( 32 P) line source of finite length. Dose profiles were obtained to demonstrate edge effects. For long lesions, the source is often stepped along the artery. Dose changes due to separation or overlapping of sources during source stepping procedures were also determined. Isodose curves were superimposed on intravascular ultrasound images to demonstrate dose levels. For an exposure time of 60 seconds with a 200mCi source, the optimum dose of 20 Gy occurs at a distance 1.94mm from the centre of the source. The upper limit of the treatment dose range (30 Gy) occurs at 1.59mm. The lower limit of the treatment dose range (10 Gy) occurs at 2.7mm. Significant perturbations to the treatment dose range can be caused by non-centering of the source, edge effects and separation or overlapping of sources in stepping procedures. Despite these concerns, many successful procedures have been reported and this implies that the model is over simplified and requires modifications. Copyright (2000) Australasian College of Physical Scientists and Engineers in Medicine

  5. Ultrasound

    Science.gov (United States)

    ... chap 66. Cosgrove DO, Eckersley RJ, Harvey CJ, Lim A. Ultrasound. In: Adam A, Dixon AK, Gillard JH, Schaefer-Prokop CM, eds. ... by: Jason Levy, MD, Northside Radiology Associates, Atlanta, GA. Also ...

  6. [Intravascular endothelioma (author's transl)].

    Science.gov (United States)

    Vanĕk, J

    1978-01-01

    A 76-year-old woman developed a slowly growing lesion over the right index and the adjacent part of the metacarpus. A cell proliferation filling up the skin veins was classified as intravascular endothelioma. This rather rare oncological entity with a good prognosis should be differentiated from peculiar pattern occasionally seen in organisation of thrombi as well as malignant endothelial tumours.

  7. The effect of continuous ultrasound on chronic low back pain: protocol of a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Naghdi Soofia

    2011-03-01

    Full Text Available Abstract Background Chronic non-specific low-back pain (LBP is one of the most common and expensive musculoskeletal disorders in industrialized countries. Similar to other countries in the world, LBP is a common health and socioeconomic problem in Iran. One of the most widely used modalities in the field of physiotherapy for treating LBP is therapeutic ultrasound. Despite its common use, there is still inconclusive evidence to support its effectiveness in this group of patients. This randomised trial will evaluate the effectiveness of continuous ultrasound in addition to exercise therapy in patients with chronic LBP. Methods and design A total of 46 patients, between the ages 18 and 65 years old who have had LBP for more than three months will be recruited from university hospitals. Participants will be randomized to receive continuous ultrasound plus exercise therapy or placebo ultrasound plus exercise therapy. These groups will be treated for 10 sessions during a period of 4 weeks. Primary outcome measures will be functional disability and pain intensity. Lumbar flexion and extension range of motion, as well as changes in electromyography muscle fatigue indices, will be measured as secondary outcomes. All outcome measures will be measured at baseline, after completion of the treatment sessions, and after one month. Discussion The results of this trial will help to provide some evidence regarding the use of continuous ultrasound in chronic LBP patients. This should lead to a more evidence-based approach to clinical decision making regarding the use of ultrasound for LBP. Trial registration Netherlands Trial Register (NTR: NTR2251

  8. Intravascular (catheter) MR imaging

    International Nuclear Information System (INIS)

    Cohen, A.M.; Hurst, G.C.; Katz, D.E.; Dverk, J.L.; Wiesen, E.J.; Czerski, L.W.; Malaya, R.; Bellon, E.M.

    1989-01-01

    Intravascular MR probes allow excellent spatial resolution and have the potential to detect arterial wall microstructure. Ultrasonic intravascular probes suggest that detailed morphologic information can assist clinical decision making. Catheter MR probes of 2--7 mm outside diameter (OD) were built of copper wire, Teflon, and parts from standard commercial catheters. The probes were connected to the surface coil receiver input of our Picker VISTA 2055HP 1.5-T imaging system. The extant (linear) body coil was used for transmit. Phantoms were constructed of coaxial glass MR tubes, filled with doped water. Watanabe rabbit aorta and human autopsy iliac artery specimens were examined within 4 hours of excision or stored by freezing. In vivo iliac arteries in dogs under general anesthesia were imaged, with percutaneous placement of the probe. Results are presented

  9. Intravascular "mulberry-like" bodies

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Klebe, J G; Henriques, U V

    1988-01-01

    Intravascular "mulberry-like" bodies in a stillborn female infant with moderate maceration are reported. The histogenesis of these structures is discussed based on light-microscopic, immunohistochemical and ultrastructural findings. No demonstrable causal relation between the intravascular lesion...... and fetal death was found, the cause of death being attributed to intrauterine asphyxia. It is concluded, that intravascular "mulberry-bodies" most likely represent artifacts due to red blood cell autolysis....

  10. Intravascular ultrasound: validation and clinical application

    NARCIS (Netherlands)

    A. van der Lugt (Aad)

    1996-01-01

    textabstractAtherogenesis is a process with an insidious onset and course. Once clinical signs and symptoms have become manifest, the obstructive lesion is usually at an advanced stage. Arteriography is the standard method for evaluation of atherosclerotic disease and has been useful in

  11. Ultrasound therapy of subacromial bursitis. A double blind trial.

    Science.gov (United States)

    Downing, D S; Weinstein, A

    1986-02-01

    Ultrasound (US) is used widely to treat patients with supraspinatus tendinitis, subacromial bursitis, or adhesive capsulitis (SSA). No double blind studies of US in the treatment of SSA, however, have been conducted. This study was designed to determine whether the addition of US can further decrease pain and increase range of motion in those receiving the usual courses of ROM exercises and nonsteroidal anti-inflammatory drugs (NSAIDs) or ROM exercises in patients with SSA. Twenty patients with SSA were randomized to receive true or sham US three times a week for four weeks. All other aspects of treatment remained constant (ROM exercises and NSAIDs or ROM exercises). The physician, the physical therapist, and the patients were blinded throughout the study regarding the delivery of the true or sham US. Of the multiple variables analyzed (pain, ROM, and function), no significant difference was found between the sham or true US groups. Although the study group was small, the results suggest that US is of little or no benefit when combined with ROM exercises and NSAIDs or ROM exercises in the treatment of SSA.

  12. Pre-procedural Ultrasound for Infant Lumbar Puncture: A randomized clinical trial.

    Science.gov (United States)

    Kessler, David; Pahalyants, Vartan; Kriger, Joshua; Behr, Gerald; Dayan, Peter

    2018-04-12

    Our purpose was to determine the potential effect of pre-procedural ultrasound to increase lumbar puncture (LP) success compared with standard palpation method. Further, we assessed feasibility of and clinician satisfaction with a standardized ultrasound protocol. This prospective, two-arm, parallel group randomized trial was conducted in a single-center pediatric emergency department. We compared pre-procedural ultrasound vs. palpation method on success with infant LPs. Infants procedure duration. Clinician satisfaction and sonographer perceptions of ultrasound acceptability and impact were assessed. Eighty-one patients consented and 80 were analyzed (99%): 40 per group. No statistical difference was seen for the primary outcome (p >0.05) between intervention and control groups (difference 3%; 95% CI -19% to 24%). There were no statistical differences between intervention and controls groups for secondary outcomes including the rate of traumatic LPs, number of attempts, and the duration of LP procedure. Most sonographers (84%) strongly agreed or agreed that the US protocol technically easy to perform, well tolerated by the patient (94%), well accepted by the family (100%), and well accepted by the LP procedural clinicians (99%). In the US group, the majority of clinicians who performed the LPs (68.4%) noted that the pre-procedural US influenced their behavior, most commonly helping with overall visualization at the selected interspace (28.9%) or prompting a change in interspace (26.3% higher, 5.3% lower). Seventy seven percent agreed or strongly agreed that they would like to use the technique again for their next LP. The mean ultrasound duration was 4.6 minutes. Pre-procedural US by did not improve the rates of first attempt success when compared with palpation method. Our results suggest ultrasound is feasible and well accepted, with a perceptible impact on care. This article is protected by copyright. All rights reserved. This article is protected by copyright

  13. Disseminated intravascular coagulation in sepsis

    NARCIS (Netherlands)

    Zeerleder, Sacha; Hack, C. Erik; Wuillemin, Walter A.

    2005-01-01

    Disseminated intravascular coagulation is a frequent complication of sepsis. Coagulation activation, inhibition of fibrinolysis, and consumption of coagulation inhibitors lead to a procoagulant state resulting in inadequate fibrin removal and fibrin deposition in the microvasculature. As a

  14. Ultrasound thrombolysis in stent thrombosis.

    Science.gov (United States)

    Rassin, T; Desmet, W; Piessens, J; Rosenschein, U

    2000-11-01

    Recent refinement in stent implantation technique and peri-procedural pharmacological treatment has lowered the incidence of stent thrombosis significantly. Still, all stent thromboses are associated with major adverse events. In previous studies it has been suggested that intravascular ultrasound fibrinolysis is safe and effective. In this report, ultrasound successfully reperfused thrombotically occluded stents. These observations suggest that ultrasound may dissolve occlusive platelet-rich thrombus effectively and safely. Cathet. Cardiovasc. Intervent. 51:332-334, 2000. Copyright 2000 Wiley-Liss, Inc.

  15. Ultrasound guided injection of dexamethasone versus placebo for treatment of plantar fasciitis: protocol for a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Gilheany Mark F

    2010-07-01

    Full Text Available Abstract Background Plantar fasciitis is the most commonly reported cause of chronic pain beneath the heel. Management of this condition commonly involves the use of corticosteroid injection in cases where less invasive treatments have failed. However, despite widespread use, only two randomised trials have tested the effect of this treatment in comparison to placebo. These trials currently offer the best available evidence by which to guide clinical practice, though both were limited by methodological issues such as insufficient statistical power. Therefore, the aim of this randomised trial is to compare the effect of ultrasound-guided corticosteroid injection versus placebo for treatment of plantar fasciitis. Methods The trial will be conducted at the La Trobe University Podiatry Clinic and will recruit 80 community-dwelling participants. Diagnostic ultrasound will be used to diagnose plantar fasciitis and participants will be required to meet a range of selection criteria. Participants will be randomly allocated to one of two treatment arms: (i ultrasound-guided injection of the plantar fascia with 1 mL of 4 mg/mL dexamethasone sodium phosphate (experimental group, or (ii ultrasound-guided injection of the plantar fascia with 1 mL normal saline (control group. Blinding will be applied to participants and the investigator performing procedures, measuring outcomes and analysing data. Primary outcomes will be pain measured by the Foot Health Status Questionnaire and plantar fascia thickness measured by ultrasound at 4, 8 and 12 weeks. All data analyses will be conducted on an intention-to-treat basis. Conclusion This will be a randomised trial investigating the effect of dexamethasone injection on pre-specified treatment outcomes in people with plantar fasciitis. Within the parameters of this protocol, the trial findings will be used to make evidence-based recommendations regarding the use of corticosteroid injection for treatment of this

  16. The Use of the OMERACT Ultrasound Tenosynovitis Scoring System in Multicenter Clinical Trials.

    Science.gov (United States)

    Ammitzbøll-Danielsen, Mads; Østergaard, Mikkel; Naredo, Esperanza; Iagnocco, Annamaria; Möller, Ingrid; D'Agostino, Maria-Antonietta; Gandjbakhch, Frédérique; Terslev, Lene

    2018-02-01

    To test the sensitivity to change of the Outcome Measures in Rheumatology Clinical Trials (OMERACT) ultrasound (US) scoring system for tenosynovitis when applied in a multicenter design. RA patients with US-verified tenosynovitis were recruited when scheduled for treatment intensification. Tenosynovitis was assessed at baseline, and 3 and 6 months followup, using the semiquantitative OMERACT scoring system. Expressed in median (25th; 75th percentiles), the overall greyscale and Doppler score decreased significantly from baseline at 4 (2; 7) and 3 (2; 6), to 6 months at 2 (0; 3) and 0 (0; 1, p The OMERACT US scoring system for tenosynovitis showed high responsiveness, supporting its use for diagnosing and monitoring tenosynovitis in multicenter trials.

  17. Randomized Clinical Trial of Virtual Reality Simulation Training for Transvaginal Gynecologic Ultrasound Skills.

    Science.gov (United States)

    Chao, Coline; Chalouhi, Gihad E; Bouhanna, Philippe; Ville, Yves; Dommergues, Marc

    2015-09-01

    To compare the impact of virtual reality simulation training and theoretical teaching on the ability of inexperienced trainees to produce adequate virtual transvaginal ultrasound images. We conducted a randomized controlled trial with parallel groups. Participants included inexperienced residents starting a training program in Paris. The intervention consisted of 40 minutes of virtual reality simulation training using a haptic transvaginal simulator versus 40 minutes of conventional teaching including a conference with slides and videos and answers to the students' questions. The outcome was a 19-point image quality score calculated from a set of 4 images (sagittal and coronal views of the uterus and left and right ovaries) produced by trainees immediately after the intervention, using the same simulator on which a new virtual patient had been uploaded. Experts assessed the outcome on stored images, presented in a random order, 2 months after the trial was completed. They were blinded to group assignment. The hypothesis was an improved outcome in the intervention group. Randomization was 1 to 1. The mean score was significantly greater in the simulation group (n = 16; mean score, 12; SEM, 0.8) than the control group (n = 18; mean score, 9; SEM, 1.0; P= .0302). The quality of virtual vaginal images produced by inexperienced trainees was greater immediately after a single virtual reality simulation training session than after a single theoretical teaching session. © 2015 by the American Institute of Ultrasound in Medicine.

  18. Dosimetry in intravascular brachytherapy

    International Nuclear Information System (INIS)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing 32 P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  19. Intravascular photoacoustic tomography for characterization of atherosclerotic lipid and inflammation

    Science.gov (United States)

    Zhang, Jian; Qin, Huan; Shi, Yujiao; Yang, Sihua; Xing, Da

    2014-09-01

    Photoacoustic imaging is a fast growing imaging technology depending on its high optical resolution of optics while taking the advantage of the high penetration depth of ultrasound. In this paper, we demonstrate the new progress in the photoacoustic imaging. Atherosclerosis is characterized by a progressive build-up of lipid in the arterial wall, which is known as plaque. Histological studies demonstrate that the primary cause of acute cardiovascular events is the rupture of atherosclerotic plaques. Lipid and inflammation within the plaque are related to influence the propensity of plaques to disrupt. Photoacoustic intravascular tomography (IVPAT) holds a great advantage in providing comprehensive morphological and functional information of plaques. Lipid relative concentration maps of atherosclerotic aorta were obtained and compared with histology. Furthermore, by selectively targeting the intravascular inflammatory cytokines, IVPAT is also capable of mapping the inflamed area and determining the degree of inflammation.

  20. Arthroscopy or ultrasound in undergraduate anatomy education: a randomized cross-over controlled trial

    Science.gov (United States)

    2012-01-01

    Background The exponential growth of image-based diagnostic and minimally invasive interventions requires a detailed three-dimensional anatomical knowledge and increases the demand towards the undergraduate anatomical curriculum. This randomized controlled trial investigates whether musculoskeletal ultrasound (MSUS) or arthroscopic methods can increase the anatomical knowledge uptake. Methods Second-year medical students were randomly allocated to three groups. In addition to the compulsory dissection course, the ultrasound group (MSUS) was taught by eight, didactically and professionally trained, experienced student-teachers and the arthroscopy group (ASK) was taught by eight experienced physicians. The control group (CON) acquired the anatomical knowledge only via the dissection course. Exposure (MSUS and ASK) took place in two separate lessons (75 minutes each, shoulder and knee joint) and introduced standard scan planes using a 10-MHz ultrasound system as well as arthroscopy tutorials at a simulator combined with video tutorials. The theoretical anatomic learning outcomes were tested using a multiple-choice questionnaire (MCQ), and after cross-over an objective structured clinical examination (OSCE). Differences in student’s perceptions were evaluated using Likert scale-based items. Results The ASK-group (n = 70, age 23.4 (20–36) yrs.) performed moderately better in the anatomical MC exam in comparison to the MSUS-group (n = 84, age 24.2 (20–53) yrs.) and the CON-group (n = 88, 22.8 (20–33) yrs.; p = 0.019). After an additional arthroscopy teaching 1% of students failed the MC exam, in contrast to 10% in the MSUS- or CON-group, respectively. The benefit of the ASK module was limited to the shoulder area (p training is profitable and attractive to students with respect to complex joint anatomy. Simultaneous teaching of basic-skills in musculoskeletal ultrasound should be performed by medical experts, but seems to be inferior to the arthroscopic 2D-3D

  1. Intravascular blood coagulation after irradiation

    International Nuclear Information System (INIS)

    Sushkevich, G.N.

    1981-01-01

    The problems of activation of intravascular blood coagulation (JVBC) at different stages after irradiation, are considered. JVBC peculiarities (disseminated intravascular syndrome (DIV) or thrombo hemorrhagic syndrome) are investigated. Literature on alterations which take place in the organism under effect of ionizing irradiation is analyzed. This analysis proves the characteristic features of thrombinogenesis activation and development of DIV syndrome not only in the early post-radiation period, but in the middle of radiation disease, as well. It is also shown that ionizing radiation activizes the hemocoagulation process and causes IVBC in the case of both local and general irradiation [ru

  2. Effectiveness of advertising availability of prenatal ultrasound on uptake of antenatal care in rural Uganda: A cluster randomized trial.

    Science.gov (United States)

    Cherniak, William; Anguyo, Geoffrey; Meaney, Christopher; Yuan Kong, Ling; Malhame, Isabelle; Pace, Romina; Sodhi, Sumeet; Silverman, Michael

    2017-01-01

    In rural Uganda pregnant women often lack access to health services, do not attend antenatal care, and tend to utilize traditional healers/birth attendants. We hypothesized that receiving a message advertising that "you will be able to see your baby by ultrasound" would motivate rural Ugandan women who otherwise might use a traditional birth attendant to attend antenatal care, and that those women would subsequently be more satisfied with care. A cluster randomized trial was conducted across eight rural sub-counties in southwestern Uganda. Sub-counties were randomized to a control arm, with advertisement of antenatal care with no mention of portable obstetric ultrasound (four communities, n = 59), or an intervention arm, with advertisement of portable obstetric ultrasound. Advertisement of portable obstetric ultrasound was further divided into intervention A) word of mouth advertisement of portable obstetric ultrasound and antenatal care (one communitity, n = 16), B) radio advertisement of only antenatal care and word of mouth advertisement of antenatal care and portable obstetric ultrasound (one community, n = 7), or C) word of mouth + radio advertisement of both antenatal care and portable obstetric ultrasound (two communities, n = 75). The primary outcome was attendance to antenatal care. 159 women presented to antenatal care across eight sub-counties. The rate of attendance was 65.1 (per 1000 pregnant women, 95% CI 38.3-110.4) where portable obstetric ultrasound was advertised by radio and word of mouth, as compared to a rate of 11.1 (95% CI 6.1-20.1) in control communities (rate ratio 5.9, 95% CI 2.6-13.0, padvertising antenatal care and portable obstetric ultrasound by radio attendance was significantly improved. This study suggests that women can be motivated to attend antenatal care when offered the concrete incentive of seeing their baby.

  3. No effect of bipolar interferential electrotherapy and pulsed ultrasound for soft tissue shoulder disorders : a randomised controlled trial

    NARCIS (Netherlands)

    Van Der Heijden, G J; Leffers, P; Wolters, P J; Verheijden, J J; van Mameren, H; Houben, J P; Bouter, L M; Knipschild, P G

    OBJECTIVE: To assess the efficacy of bipolar interferential electrotherapy (ET) and pulsed ultrasound (US) as adjuvants to exercise therapy for soft tissue shoulder disorders (SD). METHODS: Randomised placebo controlled trial with a two by two factorial design plus an additional control group in 17

  4. Ultrasound-guided lumpectomy of nonpalpable breast cancer versus wire-guided resection: a randomized clinical trial.

    NARCIS (Netherlands)

    Rahusen, F.D.; Bremers, A.J.A.; Fabry, H.F.; Taets van Amerongen, A.H.; Boom, R.P.; Meijer, S.

    2002-01-01

    BACKGROUND: The wire-guided excision of nonpalpable breast cancer often results in tumor resections with inadequate margins. This prospective, randomized trial was undertaken to investigate whether intraoperative ultrasound (US) guidance enables a better margin clearance than the wire-guided

  5. Intravascular Stenting in Microvascular Anastomoses

    DEFF Research Database (Denmark)

    Assersen, Kristine; Sørensen, Jens

    2015-01-01

    Background The effect of intravascular stenting (IVaS) on microvascular anastomoses has given adverse results. For experienced microsurgeons the benefit of IVaS is doubtful. We have investigated the potential benefit of the IVaS technique for two groups of inexperienced microsurgeons with differe...

  6. Intravascular bronchio-alveolar tumor

    International Nuclear Information System (INIS)

    Mata, J.M.; Caceres, J.; Prat, J.; Lopez, J.I.; Velilla, O.

    1991-01-01

    In 1975 Dail and Liebow described the clinical and pathological characteristics of a pulmonary tumor which they dominated intravascular bronchio-alveolar tumor (IVBAT). Our aim is to acquaint radiologists with the existence of this tumor by describing the radiologic findings in 2 patients with IVBAT, 1 with hepatic involvement ant the other with pulmonary osteoarthropathy. (author). 7 refs.; 2 figs

  7. Brachytherapy optimal planning with application to intravascular radiation therapy

    DEFF Research Database (Denmark)

    Sadegh, Payman; Mourtada, Firas A.; Taylor, Russell H.

    1999-01-01

    . Dose rate calculations are based on the sosimetry formulation of the American Association of Physicists in Medicine, Task Group 43. We apply the technique to optimal planning for intravascular brachytherapy of intimal hyperplasia using ultrasound data and 192Ir seeds. The planning includes...... determination of an optimal dwell-time sequence for a train of seeds that deliver ratiation while stepping through the vessel lesion. The results illustrate the advantage of this strategy over the common approach of delivering radiation by positioning a single train of seeds along the whole lesion....

  8. Extramedullary Hematopoiesis in Uterine Leiomyoma Associated with Numerous Intravascular Thrombi

    Directory of Open Access Journals (Sweden)

    Xiaoyan Cui

    2014-01-01

    Full Text Available We report a case of extramedullary hematopoiesis (EMH in uterine leiomyoma and associated numerous intravascular thrombi. A 29-year-old nulliparous female presented with heavy vaginal bleeding and a hematocrit of 22%. No bone marrow biopsy has been performed. She had a history of uterine leiomyomata and menorrhagia for a year. A transvaginal ultrasound confirmed the presence of a uterine leiomyoma. The patient was treated conservatively with oral contraceptive pills due to desire for fertility. However, she continued to have heavy vaginal bleeding and developed bilateral upper extremity deep vein thrombosis and multiple superficial vein thromboses after two months. An exploratory laparotomy with uterine myomectomy was performed. Gross examination of the specimen revealed a single nodular mass measuring 10.0×9.5×7.5 cm with a white-tan swirling cut surface. Microscopic examination revealed benign smooth muscle consistent with leiomyoma and numerous intravascular thrombi both with areas of EMH. Immunohistochemical stains confirmed the presence of all three benign lineages of hematopoietic cells. Occurrence of EMH in uterine leiomyoma and intravascular thrombi is very rare. It may be related to systemic hematopoietic stimulation due to severe chronic anemia and local presence of hematopoietic growth factors and/or cytokines.

  9. Percutaneous ultrasound-guided vs. intraoperative rectus sheath block for pediatric umbilical hernia repair: A randomized clinical trial.

    Science.gov (United States)

    Litz, Cristen N; Farach, Sandra M; Fernandez, Allison M; Elliott, Richard; Dolan, Jenny; Patel, Nikhil; Zamora, Lillian; Colombani, Paul M; Walford, Nebbie E; Amankwah, Ernest K; Snyder, Christopher W; Danielson, Paul D; Chandler, Nicole M

    2017-06-01

    Regional anesthesia is commonly used in children. Our hypothesis was that percutaneous ultrasound-guided (PERC) rectus sheath blocks would result in lower postoperative pain scores compared to intraoperative (IO) rectus sheath blocks following umbilical hernia repair. A single-institution randomized blinded trial was conducted in pediatric patients undergoing elective umbilical hernia repair. The primary outcome was mean postoperative Wong-Baker pain score. Secondary outcomes included narcotic requirements and length of postoperative stay. Fifty-eight patients were included: 28 PERC and 30 IO. Operating room time was significantly longer in the PERC group (41 vs. 35min, pblocks resulted in similar mean postoperative pain scores. There were no differences in secondary outcomes such as time to first narcotic, narcotic requirements, and length of stay. The additional resources required to complete a percutaneous ultrasound-guided rectus sheath block may not be warranted. Randomized controlled trial. Level I. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Re-evaluation of low intensity pulsed ultrasound in treatment of tibial fractures (TRUST): randomized clinical trial

    OpenAIRE

    Busse, Jason W; Bhandari, Mohit; Einhorn, Thomas A; Schemitsch, Emil; Heckman, James D; Tornetta, Paul; Leung, Kwok-Sui; Heels-Ansdell, Diane; Makosso-Kallyth, Sun; Della Rocca, Gregory J; Jones, Clifford B; Guyatt, Gordon H

    2016-01-01

    Objective?To determine whether low intensity pulsed ultrasound (LIPUS), compared with sham treatment, accelerates functional recovery and radiographic healing in patients with operatively managed tibial fractures. Design?A concealed, randomized, blinded, sham controlled clinical trial with a parallel group design of 501 patients, enrolled between October 2008 and September 2012, and followed for one year. Setting?43 North American academic trauma centers. Participants?Skeletally mature men or...

  11. Longitudinal quality control methodology for the quantitative ultrasound Achilles+ in clinical trial settings.

    Science.gov (United States)

    Hans, D; Wacker, W; Genton, L; Paris, E; Le-Floch, C; Slosman, D

    2002-10-01

    Appropriate quality assurance (QA) and quality control (QC) procedures have been well developed and validated for dual X-ray absorptiometry (DXA), and are widely applied in multicenter clinical trials to monitor device stability used to check the treatment effects on bone mineral density. This is not yet the case for quantitative ultrasound (QUS) technology, for which no QC approaches have yet been fully tested. The first Achilles (GE-Lunar Corporation, Madison, WI, USA) has been on the market for 10 years (1991). The goal of this study was to develop the QC methodology for the QUS Achilles+ device using its past/current experience (log and maintenance files.) as well as by integrating the progress made over the last years in the ultrasound domain so as to better understand the influence of temperature on ultrasound parameters. Because of the lack of confidence in the external black rubber phantom used in daily QC with the Achilles+, to monitor the device stability, we selected several QC parameters known to be influenced by potential malfunctions as experienced by the maintenance department of GE-Lunar company as well as the physical approach. These are phantom temperature-adjusted speed of sound (PSOS-TC) and broadband ultrasound attenuation (PBUA-TC), water speed of sound error (WSE), water spectrum slope (WSS) and water gain (WG). We used four Achilles+ devices perfectly stable during their entire QC range, to calculate the optimum thresholds (based mostly on 95% confidence interval) for each of these parameters as well as the precision for the in vitro SOS and BUA. An additional not fully stable Achilles device has been used to run a QC procedure example. The precision expressed as the CV was 0.22% and 0.65% for the PSOS-TC and PBUA-TC, respectively. The alarm thresholds used for QC process are +/- 0.6%, +/- 1.9%, +/- 6.8 m/s, +/- 5.3% and +/- 7.3% for the PSOS-TC, PBUA-TC, WSE, WSS and WG, respectively. Applying a logical approach on the impact of each

  12. Effectiveness of advertising availability of prenatal ultrasound on uptake of antenatal care in rural Uganda: A cluster randomized trial.

    Directory of Open Access Journals (Sweden)

    William Cherniak

    Full Text Available In rural Uganda pregnant women often lack access to health services, do not attend antenatal care, and tend to utilize traditional healers/birth attendants. We hypothesized that receiving a message advertising that "you will be able to see your baby by ultrasound" would motivate rural Ugandan women who otherwise might use a traditional birth attendant to attend antenatal care, and that those women would subsequently be more satisfied with care. A cluster randomized trial was conducted across eight rural sub-counties in southwestern Uganda. Sub-counties were randomized to a control arm, with advertisement of antenatal care with no mention of portable obstetric ultrasound (four communities, n = 59, or an intervention arm, with advertisement of portable obstetric ultrasound. Advertisement of portable obstetric ultrasound was further divided into intervention A word of mouth advertisement of portable obstetric ultrasound and antenatal care (one communitity, n = 16, B radio advertisement of only antenatal care and word of mouth advertisement of antenatal care and portable obstetric ultrasound (one community, n = 7, or C word of mouth + radio advertisement of both antenatal care and portable obstetric ultrasound (two communities, n = 75. The primary outcome was attendance to antenatal care. 159 women presented to antenatal care across eight sub-counties. The rate of attendance was 65.1 (per 1000 pregnant women, 95% CI 38.3-110.4 where portable obstetric ultrasound was advertised by radio and word of mouth, as compared to a rate of 11.1 (95% CI 6.1-20.1 in control communities (rate ratio 5.9, 95% CI 2.6-13.0, p<0.0001. Attendance was also improved in women who had previously seen a traditional healer (13.0, 95% CI 5.4-31.2 compared to control (1.5, 95% CI 0.5-5.0, rate ratio 8.7, 95% CI 2.0-38.1, p = 0.004. By advertising antenatal care and portable obstetric ultrasound by radio attendance was significantly improved. This study suggests that women can

  13. Intravascular imaging comparison of two metallic limus-eluting stents abluminally coated with biodegradable polymers: IVUS and OCT results of the DESTINY trial.

    Science.gov (United States)

    Costa, J Ribamar; Chamié, Daniel; Abizaid, Alexandre A C; Ribeiro, Expedito; Meireles, George C; Prudente, Maurício; Campos, Carlos A; Castro, Juliana P; Costa, Ricardo; Lemos, Pedro A

    2017-02-01

    We sought to compare, by means of IVUS and OCT imaging, the performance of a novel sirolimus-eluting drug-eluting stent (DES) with biodegradable polymer (Inspiron™) to the Biomatrix™ DES. From the DESTINY trial, a total of 70 randomized patients (2:1) were enrolled in the IVUS substudy (Inspiron™, n = 46; Biomatrix™: n = 20) while 25 patients were evaluated with OCT (Inspiron™, n = 19; Biomatrix™: n = 06) at 9-month follow-up. The main endpoints were % of neointimal tissue obstruction (IVUS) and neointimal stut coverage (OCT) at 9 months. Patients treated with both DES had very little NIH formation at 9 months either by IVUS (% of NIH obstruction of 4.9 ± 4.1 % with Inspiron™ vs. 2.7 ± 2.9 % with Biomatrix™, p = 0.03) or by OCT (neointimal thickness of 144.2 ± 72.5 µm Inspiron™ vs. 115.0 ± 53.9 µm with Biomatrix™, p = 0.45). Regarding OCT strut-level assessment, again both devices showed excellent 9-month performance, with high rates of strut coverage (99.49 ± 1.01 % with Inspiron™ vs. 97.62 ± 2.21 % with Biomatrix™, p < 0.001) and very rare malapposition (0.29 ± 1.06 % with Inspiron™ vs. 0.53 ± 0.82 % with Biomatrix™, p = 0.44). Patients with any uncovered struts were more frequently identified in the Biomatrix™ group (9.78 ± 7.13 vs. 2.29 ± 3.91 %, p < 0.001). In the present study, midterm IVUS and OCT evaluations showed that both new generation DES with biodegradable polymer were effective in terms of suppressing excessive neointimal response, with very high rates of apposed and covered struts, suggesting a consistent and benign healing pattern.

  14. Ultrasound-guided sclerosis of neovessels in painful chronic patellar tendinopathy: a randomized controlled trial.

    Science.gov (United States)

    Hoksrud, Aasne; Ohberg, Lars; Alfredson, Håkan; Bahr, Roald

    2006-11-01

    Color Doppler ultrasound examination frequently reveals neovascularization in chronic painful Achilles and patellar tendinopathy. Sclerosing the area with vascular ingrowth using polidocanol has shown promising clinical results in patients with Achilles tendinopathy. To investigate sclerosing treatment using polidocanol on a group of elite athletes with patellar tendinopathy. Randomized controlled trial/cross-over study; Level of evidence, 1. The authors recruited 33 patients (42 tendons), mainly from the Norwegian elite divisions in basketball, team handball, and volleyball. Seventeen patients (23 knees) were randomized to the treatment group (polidocanol injections in the area of neovascularization) and 16 patients (20 knees) to the control group (similar injections with lidocaine/epinephrine). After 4 months of treatment, the control group was crossed over to active treatment. Pain and function were recorded using the Victorian Institute of Sport Assessment score before the start of treatment and 4, 8, and 12 months after the first injection. Victorian Institute of Sport Assessment scores between groups were compared using multivariate analysis of variance for repeated measures. The treatment group reported a significant improvement in Victorian Institute of Sport Assessment score from 51 to 62 after 4 months; there was no change for the control group (group by time interaction, P = .052). After 8 months, when the control group had also received active treatment with polidocanol, they had a greater improvement in Victorian Institute of Sport Assessment score (58-79) than did the treatment group (54-70; group by time interaction, P = .022; time effect, P patellar tendinopathy.

  15. The Maastricht Ultrasound Shoulder pain trial (MUST: Ultrasound imaging as a diagnostic triage tool to improve management of patients with non-chronic shoulder pain in primary care

    Directory of Open Access Journals (Sweden)

    Cals Jochen WL

    2011-07-01

    Full Text Available Abstract Background Subacromial disorders are considered to be one of the most common pathologies affecting the shoulder. Optimal therapy for shoulder pain (SP in primary care is yet unknown, since clinical history and physical examination do not provide decisive evidence as to the patho-anatomical origin of the symptoms. Optimal decision strategies can be furthered by applying ultrasound imaging (US, an accurate method in diagnosing SP, demonstrating a clear relationship between diagnosis and available therapies. Yet, the clinical cost-effectiveness of applying US in the management of SP in primary care has not been studied. The aim of this paper is to describe the design and methods of a trial assessing the cost-effectiveness of ultrasound imaging as a diagnostic triage tool to improve management of primary care patients with non-chronic shoulder pain. Methods/Design This randomised controlled trial (RCT will involve 226 adult patients with suspected subacromial disorders recruited by general practitioners. During a Qualification period of two weeks, patients receive care as usual as advised by the Dutch College of General Practitioners, and patients are referred for US. Patients with insufficient improvement qualify for the RCT. These patients are then randomly assigned to the intervention or the control group. The therapies used in both groups are the same (corticosteroid injections, referral to a physiotherapist or orthopedic surgeon except that therapies used in the intervention group will be tailored based on the US results. Ultrasound diagnosed disorders include tendinopathy, calcific tendinitis, partial and full thickness tears, and subacromial bursitis. The primary outcome is patient-perceived recovery at 52 weeks, using the Global Perceived Effect questionnaire. Secondary outcomes are disease specific and generic quality of life, cost-effectiveness, and the adherence to the initial applied treatment. Outcome measures will be assessed

  16. Ultrasound-Guided Percutaneous Dilational Tracheostomy: A Systematic Review of Randomized Controlled Trials and Meta-Analysis.

    Science.gov (United States)

    Gobatto, André L N; Besen, Bruno A M P; Cestari, Mino; Pelosi, Paolo; Malbouisson, Luiz M S

    2018-01-01

    Percutaneous dilational tracheostomy (PDT) is a common and increasingly used procedure in the intensive care unit (ICU). It is usually performed with bronchoscopy guidance. Ultrasound has emerged as a useful tool in order to assist PDT, potentially improving its success rate and reducing procedural-related complications. To investigate whether the ultrasound-guided PDT is equivalent or superior to the bronchoscopy-guided or anatomical landmarks-guided PDT with regard to procedural-related and clinical complications. A systematic review of randomized clinical trials was conducted comparing an ultrasound-guided PDT to the control groups (either a bronchoscopy-guided PDT or an anatomical landmark-guided PDT) in patients undergoing a PDT in the ICU. The primary outcome was the incidence of major procedural-related and clinical complication rates. The secondary outcome was the incidence of minor complication rates. Random-effect meta-analyzes were used to pool the results. Four studies fulfilled the inclusion criteria and they were analyzed. The studies included 588 participants. There were no differences in the major complication rates between the patients who were assigned to the ultrasound-guided PDT when compared to the control groups (pooled risk ratio [RR]: 0.48; 95% confidence interval [CI]: 0.13-1.71, I 2 = 0%). The minor complication rates were not different between the groups, but they had a high heterogeneity (pooled RR: 0.49; 95% CI 0.16-1.50; I 2 = 85%). The sensitivity analyzes that only included the randomized controlled trials that used a landmark-guided PDT as the control group showed lower rates of minor complications in the ultrasound-guided PDT group (pooled RR: 0.55; 95% CI: 0.31-0.98, I 2 = 0%). The ultrasound-guided PDT seems to be safe and it is comparable to the bronchoscopy-guided PDT regarding the major and minor procedural-related or clinical complications. It also seems to reduce the minor complications when compared to the anatomical

  17. CNS Intravascular Lymphoma: A Case Report

    Directory of Open Access Journals (Sweden)

    Amer Awad

    2011-01-01

    Full Text Available Intravascular lymphoma is a rare but well-described entity. The clinical manifestations are heterogeneous. We report a case of a 59-year-old woman who presented initially with syncope followed by subacute cognitive decline that progressed to minimally conscious state. Shortly after the transfer to our tertiary center the patient died. Brain autopsy disclosed the diagnosis of B-cell intravascular lymphoma. We speculate that syncope could be the first manifestation of central nervous system intravascular lymphoma and should be considered in the differential diagnosis of unexplained syncope. In addition, we stress the importance of early brain biopsy in unexplained white matter disease.

  18. High speed intravascular photoacoustic imaging of atherosclerotic arteries (Conference Presentation)

    Science.gov (United States)

    Piao, Zhonglie; Ma, Teng; Qu, Yueqiao; Li, Jiawen; Yu, Mingyue; He, Youmin; Shung, K. Kirk; Zhou, Qifa; Kim, Chang-Seok; Chen, Zhongping

    2016-02-01

    Cardiovascular disease is the leading cause of death in the industrialized nations. Accurate quantification of both the morphology and composition of lipid-rich vulnerable atherosclerotic plaque are essential for early detection and optimal treatment in clinics. In previous works, intravascular photoacoustic (IVPA) imaging for detection of lipid-rich plaque within coronary artery walls has been demonstrated in ex vivo, but the imaging speed is still limited. In order to increase the imaging speed, a high repetition rate laser is needed. In this work, we present a high speed integrated IVPA/US imaging system with a 500 Hz optical parametric oscillator laser at 1725 nm. A miniature catheter with 1.0 mm outer diameter was designed with a 200 μm multimode fiber and an ultrasound transducer with 45 MHz center frequency. The fiber was polished at 38 degree and enclosed in a glass capillary for total internal reflection. An optical/electrical rotary junction and pull-back mechanism was applied for rotating and linearly scanning the catheter to obtain three-dimensional imaging. Atherosclerotic rabbit abdominal aorta was imaged as two frame/second at 1725 nm. Furthermore, by wide tuning range of the laser wavelength from 1680 nm to 1770 nm, spectroscopic photoacoustic analysis of lipid-mimicking phantom and an human atherosclerotic artery was performed ex vivo. The results demonstrated that the developed IVPA/US imaging system is capable for high speed intravascular imaging for plaque detection.

  19. Ultrasound or near-infrared vascular imaging to guide peripheral intravenous catheterization in children: a pragmatic randomized controlled trial.

    Science.gov (United States)

    Curtis, Sarah J; Craig, William R; Logue, Erin; Vandermeer, Ben; Hanson, Amanda; Klassen, Terry

    2015-05-19

    Peripheral intravenous catheterization in children is challenging, and success rates vary greatly. We conducted a pragmatic randomized controlled trial to determine whether the use of ultrasound or near-infrared vascular imaging to guide catheterization would be more effective than the standard approach in achieving successful catheter placement on the first attempt. We enrolled a convenience sample of 418 children in a pediatric emergency department who required peripheral intravenous catheterization between June 2010 to August 2012. We stratified them by age (≤ 3 yr and > 3 yr) and randomly assigned them to undergo the procedure with the standard approach, or with the help of either ultrasound or near-infrared vascular imaging. The primary outcome was the proportion of patients who had successful placement of a catheter on the first attempt. The rate of successful first attempts did not differ significantly between either of the 2 intervention groups and the standard approach group (differences in proportions -3.9%, 95% confidence interval [CI] -14.2% to 6.5%, for ultrasound imaging; -8.7%, 95% CI -19.4% to 1.9%, for near-infrared imaging). Among children 3 years and younger, the difference in success rates relative to standard care was also not significant for ultrasound imaging (-9.6%, 95% CI -29.8% to 10.6%), but it was significantly worse for near-infrared imaging (-20.1%, 95% CI -40.1% to -0.2%). Among children older than 3 years, the differences in success rates relative to standard care were smaller but not significant (-2.3%, 95% CI -13.6% to 9.0%, for ultrasound imaging; -4.1%, 95% CI -15.7% to 7.5%, for near-infrared imaging). None of the pairwise comparisons were statistically significant in any of the outcomes. Neither technology improved first-attempt success rates of peripheral intravenous catheterization in children, even in the younger group. These findings do not support investment in these technologies for routine peripheral intravenous

  20. Axillary Ultrasound and Laser Combined With Postisometric Facilitation in Treatment of Shoulder Adhesive Capsulitis: A Randomized Clinical Trial.

    Science.gov (United States)

    Elhafez, Haytham M; Elhafez, Salam M

    2016-06-01

    The purpose of this study was to compare axillary ultrasound, laser, and postisometric facilitation technique with standard care in the management of shoulder adhesive capsulitis. This is a randomized clinical trial study. Fifty-nine participants with shoulder adhesive capsulitis were selected and randomly assigned for eligibility. Forty-five participants were assigned into 3 equal groups of 15, and 14 participants were excluded from the study. The participants were blinded to their group allocation. Standard care group (A) received traditional physical therapy treatment in the form of pulsed ultrasound, scanning laser, supervised exercise program, and home exercise program; group B received the same physical therapy program as group A, except that the ultrasound and scanning laser were applied to the axillary region of the painful shoulder; and group C received the same modified physical therapy program as group B plus postisometric facilitation technique to the painful shoulder. All dependent variables were measured by the second author, who was blinded to the participant's intervention group. The first author administered treatment to all 3 groups. All participants received 12 sessions (3 times/wk for 4 weeks). Pain level and shoulder range of motion (ROM; flexion, abduction, and external rotation) were recorded 3 times (pretreatment, immediately posttreatment, and 4 weeks of treatment). Mixed-design multivariate analysis of variance indicated significant pain reduction with significant ROM increase in all groups posttreatment and after 4 weeks. Post hoc analysis for within groups revealed that shoulder ROM and pain levels improved significantly posttreatment compared with pretreatment ROM in all groups, with the greatest improvement in group C. Between-group analysis revealed that pain-free shoulder flexion, abduction, external rotation, and pain level improved significantly in group C compared with groups A and B immediately after treatment and after 4 weeks

  1. Randomized trial of tourniquet vs blood pressure cuff for target vein dilation in ultrasound-guided peripheral intravenous access.

    Science.gov (United States)

    Nelson, Drew; Jeanmonod, Rebecca; Jeanmonod, Donald

    2014-07-01

    Ten percent of the time, peripheral intravenous access (PIV) is not obtained in 2 attempts in the emergency department. Typically, a tourniquet is used to dilate the target vein; but recent research showed that a blood pressure (BP) cuff improves dilation, which may translate to increased PIV success. We sought to determine if there is improved success in obtaining ultrasound-guided PIV using a BP cuff vs a tourniquet in "difficult stick" patients. This is a prospective, randomized, single-blinded trial. Adult patients requiring PIV with at least 2 prior failed attempts were enrolled. Patients were assigned to tourniquet or BP cuff for target vein dilation randomly. Nurses prepared the patient for PIV attempt by either placing a BP cuff inflated to 150 mm Hg or placing a tourniquet on the chosen extremity. The extremity was draped to blind the physician to assignment. Physicians then attempted ultrasound-guided PIV. Failures were defined as IVs requiring greater than 3 ultrasound-guided attempts or 30 minutes, or patient intolerance. If failure occurred, the physician was unblinded; and the patient could be crossed over and reattempted. Thirty-eight patients were enrolled. The success rate for the tourniquet group (n = 17) and BP cuff group (n = 21) was 82.4% and 47.6%, respectively (P = .04). There were no differences between groups for vessel depth, diameter, or procedure time. Six in the BP cuff group were crossed over and had successful PIV obtained with tourniquet. Tourniquet is superior to BP cuff for target vein dilation in ultrasound-guided PIV. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Intravascular lipoma of the renal vein

    Directory of Open Access Journals (Sweden)

    Z Doyle

    2015-06-01

    Full Text Available Lipomas are benign neoplasms composed of adipocytes encased in a fibrous capsule. Intravascular lipomas are rare and almost always incidental findings. In the published literature, the majority are described within the inferior vena cava (IVC and less frequently reported in the superior vena cava, brachiocephalic vein, subclavian vein, internal jugular vein, external iliac vein and common femoral vein. We present the case of a 59-year-old male who presented with a symptomatic ureteral calculus and was found to have an intravascular lipoma of the right renal vein with extension into the IVC. To our knowledge, this is the first ever report of an intravascular lipoma in the renal vein. We discuss the imaging characteristics of intravascular lipomas and the differential diagnosis that should be considered.

  3. Intravascular Myopericytoma in the Heel: Case Report and Literature Review

    Science.gov (United States)

    Valero, José; Salcini, José L.; Gordillo, Luis; Gallart, José; González, David; Deus, Javier; Lahoz, Manuel

    2015-01-01

    Abstract Intravascular myopericytoma (IVMP), regarded as a variant of myopericytoma, is a rare tumor. Very few cases have been described, none in the foot. The first case of IVMP located in the heel of the foot is described in this article. A literature review is reported of all cases of IVMP published in the English literature. A 48-year-old man possessed an IVMP on the heel of the right foot. The physical examination and histopathological and ultrasound studies are described. The literature review yielded 5 cases of IVMP, 2 of which were in the thigh and 1 each in the oral mucosa, the periorbital region, and the leg. The possibility that these lesions may be malignant suggests that the histopathological study of vascular tumors should include immunohistochemical tests. PMID:25789958

  4. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    OpenAIRE

    Kensuke Tashiro, MD; Shuji Yamashita, MD; Mitsunaga Narushima, MD; Isao Koshima, MD; Shimpei Miyamoto, MD

    2017-01-01

    Background:. Although supermicrosurgical anastomosis is a widely known reconstructive microsurgical technique, it is difficult to perform. To expand the clinical use of supermicrosurgery, we used hemi-intravascular stenting (hemi-IVaS), which is performed by inserting an intravascular stent into one side of the vessel. We conducted lymphaticovenular anastomosis, free perforator flap transfer, and fingertip replantation with supermicrosurgical anastomosis using hemi-IVaS technique and examined...

  5. Ultrasound-guided breast-sparing surgery to improve cosmetic outcomes and quality of life. A prospective multicentre randomised controlled clinical trial comparing ultrasound-guided surgery to traditional palpation-guided surgery (COBALT trial)

    Science.gov (United States)

    2011-01-01

    Background Breast-conserving surgery for breast cancer was developed as a method to preserve healthy breast tissue, thereby improving cosmetic outcomes. Thus far, the primary aim of breast-conserving surgery has been the achievement of tumour-free resection margins and prevention of local recurrence, whereas the cosmetic outcome has been considered less important. Large studies have reported poor cosmetic outcomes in 20-40% of patients after breast-conserving surgery, with the volume of the resected breast tissue being the major determinant. There is clear evidence for the efficacy of ultrasonography in the resection of nonpalpable tumours. Surgical resection of palpable breast cancer is performed with guidance by intra-operative palpation. These palpation-guided excisions often result in an unnecessarily wide resection of adjacent healthy breast tissue, while the rate of tumour-involved resection margins is still high. It is hypothesised that the use of intra-operative ultrasonography in the excision of palpable breast cancer will improve the ability to spare healthy breast tissue while maintaining or even improving the oncological margin status. The aim of this study is to compare ultrasound-guided surgery for palpable tumours with the standard palpation-guided surgery in terms of the extent of healthy breast tissue resection, the percentage of tumour-free margins, cosmetic outcomes and quality of life. Methods/design In this prospective multicentre randomised controlled clinical trial, 120 women who have been diagnosed with palpable early-stage (T1-2N0-1) primary invasive breast cancer and deemed suitable for breast-conserving surgery will be randomised between ultrasound-guided surgery and palpation-guided surgery. With this sample size, an expected 20% reduction of resected breast tissue and an 18% difference in tumour-free margins can be detected with a power of 80%. Secondary endpoints include cosmetic outcomes and quality of life. The rationale, study

  6. Dosimetric calculus in intravascular brachytherapy; Calculos dosimetricos em braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia Pumilla Botelho; Stabin, Michael Gregory [Pernambuco Univ., Recife, PE (Brazil). Dept. de Energia Nuclear

    2000-07-01

    Among the cardiovascular diseases, the most common is acute myocardial infarction, which occurs because of the occlusion of one or more coronary arteries. Balloon angioplasty has been a popular treatment which is less invasive than surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment). Known as Intravascular Brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis. In order to study the radiation dosimetry in the patient and radiological protection for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, 0.30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several radionuclides. Two stent sources employing {sup 32}P are also simulated. Advantages and disadvantages of the radionuclides and source geometries are discussed and the dosimetry developed here will aid in the realization of the benefits obtained in patients. (author)

  7. Sustained effect of simulation-based ultrasound training on clinical performance: a randomized trial

    Science.gov (United States)

    Tolsgaard, M G; Ringsted, C; Dreisler, E; Nørgaard, L N; Petersen, J H; Madsen, M E; Freiesleben, N L C; Sørensen, J L; Tabor, A

    2015-01-01

    Objective To study the effect of initial simulation-based transvaginal sonography (TVS) training compared with clinical training only, on the clinical performance of residents in obstetrics and gynecology (Ob-Gyn), assessed 2 months into their residency. Methods In a randomized study, new Ob-Gyn residents (n = 33) with no prior ultrasound experience were recruited from three teaching hospitals. Participants were allocated to either simulation-based training followed by clinical training (intervention group; n = 18) or clinical training only (control group; n = 15). The simulation-based training was performed using a virtual-reality TVS simulator until an expert performance level was attained, and was followed by training on a pelvic mannequin. After 2 months of clinical training, one TVS examination was recorded for assessment of each resident's clinical performance (n = 26). Two ultrasound experts blinded to group allocation rated the scans using the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale. Results During the 2 months of clinical training, participants in the intervention and control groups completed an average ± SD of 58 ± 41 and 63 ± 47 scans, respectively (P = 0.67). In the subsequent clinical performance test, the intervention group achieved higher OSAUS scores than did the control group (mean score, 59.1% vs 37.6%, respectively; P Simulation-based ultrasound training leads to substantial improvement in clinical performance that is sustained after 2 months of clinical training. © 2015 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology. PMID:25580809

  8. The analgesic efficacy of ultrasound-guided modified rectus sheath block compared with wound infiltration in reduction of postoperative morphine consumption in women undergoing open hysterectomy or myomectomy: A randomized controlled trial 14/09/2012 trial

    OpenAIRE

    Mukesh Kumar Shah; Sandeep S Kulkarni; Wendy Fun

    2012-01-01

    Introduction: As ultrasound allows more accurate placement of local anesthetic (LA), ultrasound-guided modified rectus sheath block (MRSB) was compared with wound infiltration (WI) in women having open hysterectomy or myomectomy for fibroids via a Pfannenstiel incision under general anesthesia. Materials and Methods: Forty-two American Society of Anesthesiologists Class ASA I,II and III patients were recruited into two groups in a randomized patient-blinded controlled trial excluding thos...

  9. Does the integration of personalized ultrasound change patient management in critical care medicine? Observational trials.

    Science.gov (United States)

    Breitkreutz, Raoul; Campo Delľ Orto, Marco; Hamm, Christian; Cuca, Colleen; Zechner, Peter M; Stenger, Tanja; Walcher, Felix; Seeger, Florian H

    2013-01-01

    Objective. To test the influence of personalized ultrasound (PersUS) on patient management in critical care. Design of the Study. Prospective, observational, and critical care setting. Four substudies compared PersUS and mobile ultrasound, work distribution, and diagnostic and procedural quality. Patients and Interventions. 640 patient ultrasound exams including 548 focused diagnostic exams and 92 interventional procedures. Main Outcome Measures. Number of studies, physician's judgement of feasibility, time of usage per patient, and referrals to echo lab. Results. Randomized availability of PersUS increased its application in ICU work shifts more than twofold from 33 to 68 exams mainly for detection and therapy of effusions. Diagnostic and procedural quality was rated as excellent/very good in PersUS-guided puncture in 95% of cases. Integrating PersUS within an initial physical examination of 48 randomized cases in an emergency department, PersUS extended the examination time by 100 seconds. Interestingly, PersUS integration into 53 randomized regular ward rounds of 1007 patients significantly reduced average contact time per patient by 103 seconds from 8.9 to 7.2 minutes. Moreover, it lowered the patient referral rate to an echo lab from 20% to 2% within the study population. Conclusions. We propose the development of novel ultrasound-based clinical pathways by integration of PersUS.

  10. Does the Integration of Personalized Ultrasound Change Patient Management in Critical Care Medicine? Observational Trials

    Directory of Open Access Journals (Sweden)

    Raoul Breitkreutz

    2013-01-01

    Full Text Available Objective. To test the influence of personalized ultrasound (PersUS on patient management in critical care. Design of the Study. Prospective, observational, and critical care setting. Four substudies compared PersUS and mobile ultrasound, work distribution, and diagnostic and procedural quality. Patients and Interventions. 640 patient ultrasound exams including 548 focused diagnostic exams and 92 interventional procedures. Main Outcome Measures. Number of studies, physician’s judgement of feasibility, time of usage per patient, and referrals to echo lab. Results. Randomized availability of PersUS increased its application in ICU work shifts more than twofold from 33 to 68 exams mainly for detection and therapy of effusions. Diagnostic and procedural quality was rated as excellent/very good in PersUS-guided puncture in 95% of cases. Integrating PersUS within an initial physical examination of 48 randomized cases in an emergency department, PersUS extended the examination time by 100 seconds. Interestingly, PersUS integration into 53 randomized regular ward rounds of 1007 patients significantly reduced average contact time per patient by 103 seconds from 8.9 to 7.2 minutes. Moreover, it lowered the patient referral rate to an echo lab from 20% to 2% within the study population. Conclusions. We propose the development of novel ultrasound-based clinical pathways by integration of PersUS.

  11. [Which learning methods are expected for ultrasound training? Blended learning on trial].

    Science.gov (United States)

    Röhrig, S; Hempel, D; Stenger, T; Armbruster, W; Seibel, A; Walcher, F; Breitkreutz, R

    2014-10-01

    Current teaching methods in graduate and postgraduate training often include frontal presentations. Especially in ultrasound education not only knowledge but also sensomotory and visual skills need to be taught. This requires new learning methods. This study examined which types of teaching methods are preferred by participants in ultrasound training courses before, during and after the course by analyzing a blended learning concept. It also investigated how much time trainees are willing to spend on such activities. A survey was conducted at the end of a certified ultrasound training course. Participants were asked to complete a questionnaire based on a visual analogue scale (VAS) in which three categories were defined: category (1) vote for acceptance with a two thirds majority (VAS 67-100%), category (2) simple acceptance (50-67%) and category (3) rejection (learning program with interactive elements, short presentations (less than 20 min), incorporating interaction with the audience, hands-on sessions in small groups, an alternation between presentations and hands-on-sessions, live demonstrations and quizzes. For post-course learning, interactive and media-assisted approaches were preferred, such as e-learning, films of the presentations and the possibility to stay in contact with instructors in order to discuss the results. Participants also voted for maintaining a logbook for documentation of results. The results of this study indicate the need for interactive learning concepts and blended learning activities. Directors of ultrasound courses may consider these aspects and are encouraged to develop sustainable learning pathways.

  12. Does the Integration of Personalized Ultrasound Change Patient Management in Critical Care Medicine? Observational Trials

    Science.gov (United States)

    Breitkreutz, Raoul; Campo delľ Orto, Marco; Hamm, Christian; Cuca, Colleen; Zechner, Peter M.; Stenger, Tanja; Walcher, Felix; Seeger, Florian H.

    2013-01-01

    Objective. To test the influence of personalized ultrasound (PersUS) on patient management in critical care. Design of the Study. Prospective, observational, and critical care setting. Four substudies compared PersUS and mobile ultrasound, work distribution, and diagnostic and procedural quality. Patients and Interventions. 640 patient ultrasound exams including 548 focused diagnostic exams and 92 interventional procedures. Main Outcome Measures. Number of studies, physician's judgement of feasibility, time of usage per patient, and referrals to echo lab. Results. Randomized availability of PersUS increased its application in ICU work shifts more than twofold from 33 to 68 exams mainly for detection and therapy of effusions. Diagnostic and procedural quality was rated as excellent/very good in PersUS-guided puncture in 95% of cases. Integrating PersUS within an initial physical examination of 48 randomized cases in an emergency department, PersUS extended the examination time by 100 seconds. Interestingly, PersUS integration into 53 randomized regular ward rounds of 1007 patients significantly reduced average contact time per patient by 103 seconds from 8.9 to 7.2 minutes. Moreover, it lowered the patient referral rate to an echo lab from 20% to 2% within the study population. Conclusions. We propose the development of novel ultrasound-based clinical pathways by integration of PersUS. PMID:24455272

  13. Coagulación intravascular diseminada = Disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Arango Barrientos, Marcos

    2010-12-01

    Full Text Available La coagulación intravascular diseminada (CID es una entidad clínica frecuente que se presenta como fenómeno secundario a diversas enfermedades entre las cuales se destacan las infecciones graves, las neoplasias y las catástrofes obstétricas. Se caracteriza por una activación difusa y simultánea de los sistemas endógenos de la coagulación y la fibrinólisis. El depósito de pequeños trombos en la circulación conduce finalmente a disfunción orgánica múltiple y en algunos casos a la muerte. Las manifestaciones clínicas pueden incluir fenómenos trombóticos y hemorrágicos. Se ha propuesto un puntaje de fácil aplicación para simplificar el diagnóstico de la entidad. El tratamiento incluye el control específico de la causa subyacente que favorece la aparición de la CID, el soporte con hemoderivados en pacientes con manifestaciones de sangrado y la anticoagulación terapéutica en pacientes con trombosis mayores. El desarrollo de CID es un factor pronóstico adverso que aumenta significativamente la tasa de mortalidad. En este artículo de revisión se incluyen los siguientes aspectos de la CID: historia, epidemiología, clasificación, entidades asociadas, fisiopatología, clínica, diagnóstico, tratamiento y pronóstico.

  14. Dosimetry in intravascular brachytherapy; Calculos dosimetricos em braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing {sup 32} P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  17. Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: An updated meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Bhattacharjee, Sulagna; Maitra, Souvik; Baidya, Dalim K

    2018-03-22

    Possible advantages and risks associated with ultrasound guided radial artery cannulation in-comparison to digital palpation guided method in adult patients are not fully known. We have compared ultrasound guided radial artery cannulation with digital palpation technique in this meta-analysis. Meta-analysis of randomized controlled trials. Trials conducted in operating room, emergency department, cardiac catheterization laboratory. PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were searched (from 1946 to 20th November 2017) to identify prospective randomized controlled trials in adult patients. Two-dimensional ultrasound guided radial artery catheterization versus digital palpation guided radial artery cannulation. Overall cannulation success rate, first attempt success rate, time to cannulation and mean number of attempts to successful cannulation. Odds ratio (OR) and standardized mean difference (SMD) or mean difference (MD) with 95% confidence interval (CI) were calculated for categorical and continuous variables respectively. Data of 1895 patients from 10 studies have been included in this meta- analysis. Overall cannulation success rate was similar between ultrasound guided technique and digital palpation [OR (95% CI) 2.01 (1.00, 4.06); p = 0.05]. Ultrasound guided radial artery cannulation is associated with higher first attempt success rate of radial artery cannulation in comparison to digital palpation [OR (95% CI) 2.76 (186, 4.10); p guided technique with palpation technique. Radial artery cannulation by ultrasound guidance may increase the first attempt success rate but not the overall cannulation success when compared to digital palpation technique. However, results of this meta-analysis should be interpreted with caution due presence of heterogeneity. Copyright © 2018. Published by Elsevier Inc.

  18. Ultrasound to stimulate early bone formation in a distraction gap : a double blind randomised clinical pilot trial in the edentulous mandible

    NARCIS (Netherlands)

    Schortinghuis, J; Bronckers, ALLJ; Stegenga, B; Raghoebar, GM; de Bont, LGM

    Objective: In a double blind randomised clinical pilot trial, it was investigated whether tow intensity pulsed ultrasound therapy stimulates early bone formation in a distraction gap created in a severely resorbed mandible. Design: Eight patients underwent a mandibular vertical distraction over an

  19. Prediction of outcome after femoropopliteal balloon angioplasty by intravascular ultrasound

    DEFF Research Database (Denmark)

    Vogt, K C; Just, S; Rasmussen, John Bøje Grønvall

    1997-01-01

    limbs) undergoing PTA of the superficial femoral or popliteal artery. The degree of stenosis, the diameter and area of the lumen and the morphological changes in the plaque were related to the short-term patency of the intervention, as evaluated by duplex scan and ankle branchial index. RESULTS: Fifteen...... arteries remained patent. Two occlusions and two stenoses developed during the first 3 months after the intervention and one occlusion occurred after 1 year. The following IVUS parameters were related to a favourable patency: presence of calcification; dissection or plaque rupture and residual stenosis...

  20. Intravascular ultrasound for iliac artery imaging. Clinical review

    DEFF Research Database (Denmark)

    Vogt, K G; Schroeder, T V

    2001-01-01

    IVUS is able to produce trans-sectional images of the iliac arteries at a high resolution. The three layered appearance of the arterial wall can be visualized. In the atherosclerotic diseased artery calcified plaques can be discerned from non-calcified plaques, and the distribution of the plaque......-eccentric or concentric-can be determined. IVUS seems to be superior to arteriography in quantifying the degree of stenosis, being able to relate the luminal area to the mediabounded area at the same site of the artery. The discrepancy between IVUS and arteriography is even greater when evaluating residualstenosis after...

  1. Effect of oral contraceptive with and without associated estriol on ultrasound measurements of breast fibroadenoma: randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Rodrigo Augusto Fernandes Estevão

    Full Text Available CONTEXT AND OBJECTIVE: Fibroadenomas are the most common benign tumors of the female breast. The aim of this study was to evaluate the proliferative activity of breast fibroadenoma as shown by ultrasound measurements, following administration of oral contraceptives with and without associated estriol. DESIGN AND SETTING: This was a randomized, double-blind, placebo-controlled clinical trial carried out in the Mastology Sector, Department of Gynecology, Universidade Federal de São Paulo. METHODS: We studied 33 women with fibroadenomas. Ten were placed in group 1 and took an oral contraceptive consisting of levonorgestrel and ethinyl estradiol together with placebo material in the same capsule, for four consecutive cycles with a seven-day interval between them. The other 23 patients constituted group 2 and took the oral contraceptive as above together with estriol in the same capsule, in the same way as done by the group 1 patients. We took ultrasound measurements of their tumors (in three dimensions before and after the intake of medication. At the end of the study, all the patients had their tumors removed by surgery. RESULTS: We observed decreased fibroadenoma width among the users of oral contraceptives with placebo, and this decrease was statistically significant. In the other group, we did not observe any changes (in width, length or height. CONCLUSION: The results confirm that estriol may block the protective effect of oral contraceptives on fibroadenomas, since we observed decreased fibroadenoma width among the group 1 patients but not the group 2 patients.

  2. No change in impedance upon intravascular injection of D5W.

    Science.gov (United States)

    Chin, James; Tsui, Ban C H

    2010-06-01

    Electrical impedance increases following test injections of non-conducting solutions around nerves; however, this increase should diminish rapidly with intravascular needle placement, wherein the systemic circulation will dissipate the solution. For this observational study, we hypothesized that the impedance increases significantly at the perineural space after an injection of 5% dextrose in water (D5W), but that it does not increase correspondingly at the intravascular location After Ethics Research Board approval, electrical impedance was measured by a nerve stimulator displaying resistance, Stimuplex HNS 12, before and during (30 sec) an injection of D5W 3 mL: 1) during intravenous cannula placement using an insulated stimulating needle sheathed in its plastic cannula, MultiSet NanoLine with 18G needle; and 2) during needle placement (Pajunk 22G insulated) for an ultrasound-guided supraclavicular block in patients undergoing hand surgery. The impedance changes at each location were analyzed and compared. Data were collected from 16 patients. Baseline impedance was lower intravascularly (mean 16.5 +/- standard deviation 7.2 kOmega) compared with perineurally (23.5 +/- 8.3 kOmega) (P = 0.037). Peak impedance after intravascular D5W injection was 20.1 +/- 6.8 kOmega, which was not a significant change (P = 0.15). In contrast, peak impedance after perineural D5W injection was 58.6 +/- 29.1 kOmega, an increase of 35.1 +/- 26.4 kOmega (155 +/- 117%), and then it reached a plateau of 36.7 +/- 19.6 kOmega. The increase in impedance was significantly greater at the perineural location (P < 0.0001). The absence of a significant increase in impedance upon injection of D5W prior to injection of local anesthetic may provide useful information to warn of intravascular injection.

  3. Fluorescent Method for Observing Intravascular Bonghan Duct

    Directory of Open Access Journals (Sweden)

    Byung-Cheon Lee

    2005-12-01

    Full Text Available Observation of intra-vascular threadlike structures in the blood vessels of rats is reported with the images by differential interference contrast microscope, and fluorescence inverted microscope of the acridine-orange stained samples. The confocal microscope image and the hematoxylin-eosin staining revealed the distinctive pattern of nuclei distribution that clearly discerned the threadlike structure from fibrin, capillary, small venule, arteriole, or lymph vessel. Physiological function of the intra-vascular thread in connection with acupuncture is discussed. Especially, this threadlike duct can be a circulation path for herb-liquid flow, which may provide the scientific mechanism for therapeutic effect of herbal acupuncture.

  4. First-trimester risk assessment based on ultrasound and cell-free DNA vs combined screening: a randomized controlled trial.

    Science.gov (United States)

    Kagan, K O; Sroka, F; Sonek, J; Abele, H; Lüthgens, K; Schmid, M; Wagner, P; Brucker, S; Wallwiener, D; Hoopmann, M

    2017-09-19

    This was a randomized controlled trial to compare risk assessment by first-trimester combined screening (FTCS) with an approach that combines a detailed ultrasound examination at 11-13 weeks' gestation and cell-free DNA (cfDNA) analysis. Pregnant women with a normal first-trimester ultrasound examination at 11-13 weeks' gestation (fetal nuchal translucency (NT) ≤ 3.5 mm and no fetal defects) were randomized into one of two groups. In the first group, risk of aneuploidy was assessed using FTCS based on the most recent UK Fetal Medicine Foundation algorithm. In the second group, risk assessment was based on ultrasound findings and cfDNA analysis. An additional tube of blood was collected for FTCS in case the cfDNA analysis was uninformative. Primary outcome was false-positive rate in screening for trisomy 21. A case was considered false positive if the karyotype was not trisomy 21 and if the risk for trisomy 21 was >1:100, irrespective of the method of risk calculation. Results were compared using 95% CIs using the Clopper-Pearson method. Between October 2015 and December 2016, 1518 women with singleton pregnancy underwent first-trimester screening. Thirty-one (2.0%) pregnancies were not eligible for randomization due to increased NT (> 3.5 mm) and/or fetal defect. After exclusion of women who declined randomization (n = 87) and cases of fetal death and loss to follow-up (n = 24), 688 pregnancies were randomized into the FTCS arm and 688 into the ultrasound + cfDNA analysis arm. There were no differences in maternal and gestational age, maternal weight and BMI, ethnicity, use of assisted reproduction and cigarette smoking between the two arms. In the ultrasound + cfDNA analysis arm, median risk for trisomy 21 was 1 in 10 000. None of the cases had a risk above 1: 100 (95% CI, 0.0-0.5%). In the FTCS arm, the median risk for trisomy 21 was 1 in 3787 and in 17 cases, the risk was higher than 1:100, which corresponds to 2.5% (95% CI, 1.5-3.9%) of

  5. Long-term safety and feasibility of three-vessel multimodality intravascular imaging in patients with ST-elevation myocardial infarction

    DEFF Research Database (Denmark)

    Taniwaki, Masanori; Radu, Maria D; Garcia-Garcia, Hector M

    2015-01-01

    We assessed the feasibility and the procedural and long-term safety of intracoronary (i.c) imaging for documentary purposes with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in patients with acute ST-elevation myocardial infarction (STEMI) undergoing primary PCI in the s...

  6. Ultrasound guided versus landmark guided corticosteroid injection in patients with rotator cuff syndrome: Randomised controlled trial.

    Science.gov (United States)

    Bhayana, Himanshu; Mishra, Puneet; Tandon, Anupama; Pankaj, Amite; Pandey, Rohit; Malhotra, Raskesh

    2018-03-01

    Impingement syndrome is the most common differential in a patient presenting to an orthopaedic OPD with shoulder pain. Impingement syndrome is often managed with subacromial corticosteroid injection, which can be instilled using either landmark guided (LMG) approach or with the assistance of ultrasound (US). This study was envisaged to enquire whether ultrasound assistance improves the accuracy, efficacy or safety profile of the injection. 60 patients of rotator cuff syndrome underwent diagnostic ultrasound. They were randomly assigned to receive subacromial injection of 2 ml (40 mg/ml) methylprenisolone and 2 ml of 1% lignocaine combination either by US assistance (n = 30) or using LMG assistance (n = 30). The patients were evaluated before injection and on follow up visits at day 5, week 3, week 6 and 3rd month by a single assessor. The assessor was blinded of the treatment group to which patient belonged. Clinical assessment included demographic and clinical data, accuracy of injection, VAS (0-100) for pain, Constant score with goniometer evaluation of range of motion, patient's self assessment proforma and post injection side effects if any. Initial demographic, clinical and US findings in the groups exhibited no significant differences. The accuracy of US guided injections (100%) was more when compared from LMG injection (93.3%). Both VAS and Constant score showed significant improvement following steroid injection up to 3 months of follow up. However the differences in the two groups were not significant suggesting comparable efficacy of the two approaches. (Mean VAS score decrease: 27.23 for US and 25.16 for LMG, p guided injections have a higher accuracy of drug placement in the subacromial bursa, there is no difference in terms of clinical outcomes or safety profile of either of the method. Hence US guided injections seems to be unjustified, when compared to equally efficacious and cost effective LMG steroid injection.

  7. Ultrasound-Guided Hyaluronic Acid Injections for Trigger Finger: A Double-Blinded, Randomized Controlled Trial.

    Science.gov (United States)

    Liu, Ding-Hao; Tsai, Mei-Wun; Lin, Shan-Hui; Chou, Chen-Liang; Chiu, Jan-Wei; Chiang, Chao-Ching; Kao, Chung-Lan

    2015-12-01

    To investigate the effects of ultrasound-guided injections of hyaluronic acid (HA) versus steroid for trigger fingers in adults. Prospective, double-blinded, randomized controlled study. Tertiary care center. Subjects with a diagnosis of trigger finger (N=36; 39 affected digits) received treatment and were evaluated. Subjects were randomly assigned to HA and steroid injection groups. Both study medications were injected separately via ultrasound guidance with 1 injection. The classification of trigger grading, pain, functional disability, and patient satisfaction were evaluated before the injection and 3 weeks and 3 months after the injection. At 3 months, 12 patients (66.7%) in the HA group and 17 patients (89.5%) in the steroid group exhibited no triggering of the affected fingers (P=.124). The treatment results at 3 weeks and 3 months showed similar changes in the Quinnell scale (P=.057 and .931, respectively). A statistically significant interaction effect between group and time was found for visual analog scale (VAS) and Michigan Hand Outcome Questionnaire (MHQ) evaluation (Pinjection (steroid 0.5±1.1 vs HA 2.7±2.4; Pinjection of HA demonstrated promising results for the treatment of trigger fingers. The optimal frequency, dosage, and molecular weight of HA injections for trigger fingers deserve further investigation for future clinical applications. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. Intravascular leiomyomatosis: an exceptional entity.

    Science.gov (United States)

    Brunel, I; Iacoponi, S; Hernandez, A; Diestro, M D; De Santiago, J; Zapardiel, I

    2016-01-01

    Intravenous leiomyomatosis (IVL) is a rare benign condition characterized by the proliferation of smooth muscle cells originating from either the uterine venous wall or a uterine myoma. This leiomyomatosis extends most frequently to pelvic vessels, but also occasionally into the inferior vena cava and right cardiac chambers. Preoperative diagnosis is difficult and it should be suspected in the presence of cardiac or pelvic masses in women who have undergone hysterectomy or myomectomy previously. The treatment is hysterectomy, normally associated with a bilateral oophorectomy and removing the mass or metastasis if any. The post-surgical follow-up should be performed at long-term and include exploration and imaging, either ultrasound or MRI. The association of antiestrogenic drugs can be useful for disease control, especially in cases where oophorectomy is not performed and the tumor cannot be removed completely.

  9. Pulsed magnetic field versus ultrasound in the treatment of postnatal carpal tunnel syndrome: A randomized controlled trial in the women of an Egyptian population

    Directory of Open Access Journals (Sweden)

    Dalia M. Kamel

    2017-01-01

    Full Text Available The aim of this study was to compare the effects of pulsed electromagnetic field versus pulsed ultrasound in treating patients with postnatal carpal tunnel syndrome. The study was a randomized, double-blinded trial. Forty postnatal female patients with idiopathic carpal tunnel syndrome were divided randomly into two equal groups. One group received pulsed electromagnetic field, with nerve and tendon gliding exercises for the wrist, three times per week for four weeks. The other group received pulsed ultrasound and the same wrist exercises. Pain level, sensory and motor distal latencies and conduction velocities of the median nerve, functional status scale and hand grip strength were assessed pre- and post-treatment. There was a significant decrease (P  0.05. In conclusion, while the symptoms were alleviated in both groups, pulsed electromagnetic field was more effective than pulsed ultrasound in treating postnatal carpal tunnel syndrome.

  10. Neutrophils Cause an Intravascular Traffic Jam.

    Science.gov (United States)

    Minns, Martin S; Pearlman, Eric

    2018-01-10

    Neutrophil swarming is defined by large numbers of cells simultaneously and rapidly migrating to a site of injury or infection. In this issue of Cell Host & Microbe, Lee et al. (2018) demonstrate that intravascular swarming of neutrophils occurs in response to Candida albicans infection and causes vascular occlusion and pathological sequelae. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    Directory of Open Access Journals (Sweden)

    Kensuke Tashiro, MD

    2017-11-01

    Conclusions:. Hemi-IVaS could be a useful alternative to conventional intravascular stenting techniques and is also effective for supermicrosurgical perforator-to-perforator anastomosis. Further studies are needed to improve the success rate and to explore its other possible utilizations in supermicrosurgery.

  12. Intravascular volume after aneurysmal subarachnoid hemorrhage

    NARCIS (Netherlands)

    Hoff, R.G.

    2009-01-01

    Intravascular volume after aneurysmal subarachnoid hemorrhage A subarachnoid hemorrhage (SAH) from a ruptured cerebral aneurysm is a devastating disorder with an often poor prognosis. The occurrence of delayed cerebral ischemia (DCI) is one of the most important factors determining outcome in

  13. Disseminated Intravascular Coagulation Following Induction of ...

    African Journals Online (AJOL)

    Background: Disseminated Intravascular coagulopathy (DIC) has been reported following use of Misoprostol which is an old drug with new indications in Obstetrics and. Gynecology. Its effectiveness, low cost, stability in tropical conditions and ease of administration as well as side effects like gastrointestinal effect, uterine ...

  14. Osteopathic manual treatment and ultrasound therapy for chronic low back pain: a randomized controlled trial.

    Science.gov (United States)

    Licciardone, John C; Minotti, Dennis E; Gatchel, Robert J; Kearns, Cathleen M; Singh, Karan P

    2013-01-01

    We studied the efficacy of osteopathic manual treatment (OMT) and ultrasound therapy (UST) for chronic low back pain. A randomized, double-blind, sham-controlled, 2 × 2 factorial design was used to study OMT and UST for short-term relief of nonspecific chronic low back pain. The 455 patients were randomized to OMT (n = 230) or sham OMT (n = 225) main effects groups, and to UST (n = 233) or sham UST (n = 222) main effects groups. Six treatment sessions were provided over 8 weeks. Intention-to-treat analysis was performed to measure moderate and substantial improvements in low back pain at week 12 (30% or greater and 50% or greater pain reductions from baseline, respectively). Five secondary outcomes, safety, and treatment adherence were also assessed. There was no statistical interaction between OMT and UST. Patients receiving OMT were more likely than patients receiving sham OMT to achieve moderate (response ratio [RR] = 1.38; 95% CI, 1.16-1.64; P low back pain at week 12. These improvements met the Cochrane Back Review Group criterion for a medium effect size. Back-specific functioning, general health, work disability specific to low back pain, safety outcomes, and treatment adherence did not differ between patients receiving OMT and sham OMT. Nevertheless, patients in the OMT group were more likely to be very satisfied with their back care throughout the study (P low back pain less frequently during the 12 weeks than did patients in the sham OMT group (use ratio = 0.66, 95% CI, 0.43-1.00; P = .048). Ultrasound therapy was not efficacious. The OMT regimen met or exceeded the Cochrane Back Review Group criterion for a medium effect size in relieving chronic low back pain. It was safe, parsimonious, and well accepted by patients.

  15. Randomized controlled trial comparing pudendal nerve block under ultrasound and fluoroscopic guidance.

    Science.gov (United States)

    Bellingham, Geoff A; Bhatia, Anuj; Chan, Chin-Wern; Peng, Philip W

    2012-01-01

    Although fluoroscopy is an established imaging modality for pudendal nerve block, ultrasound (US) technique allows physicians better visualization of anatomic structures. This study aimed to compare the effectiveness and safety between the US- and fluoroscopy-guided techniques. A randomized, single-blind, split-plot design was used to conduct the study. Twenty-three patients undergoing bilateral pudendal nerve blocks received US-guided injections to either the left or right side, whereas the contralateral side received a fluoroscopic-guided injection in randomized sequence. Injections consisted of 4 mL of 0.5% bupivacaine and 40 mg methylprednisone. The primary outcome was the success of the block in the distribution of the pudendal nerve along the perineum, rated as either absent, moderate, or strong. Secondary outcomes were the time to administer the blocks, quality of visualization of anatomic structures using US and fluoroscopy, distance of the final US-guided needle position from the ischial spine, and incidence of adverse effects. No differences in the degree of neural blockade were noted between US- or fluoroscopic-guided techniques for either temperature or pinprick blockade. Time to complete the procedure was significantly longer using US compared with fluoroscopy (219 [SD, 65] and 428 [SD, 151] secs, P < 0.0001). No significant differences were noted regarding the occurrence of adverse effects between the 2 techniques. Ultrasound-guided pudendal nerve blockade is as accurate as fluoroscopically guided injections when performed by an experienced clinician. However, the former took a longer time to perform.

  16. A Randomized Controlled Trial to Investigate the Effectiveness of the Prevention of Aspiration Pneumonia Using Recommendations for Swallowing Care Guided by Ultrasound Examination.

    Science.gov (United States)

    Miura, Yuka; Nakagami, Gojiro; Yabunaka, Koichi; Tohara, Haruka; Noguchi, Hiroshi; Mori, Taketoshi; Sanada, Hiromi

    2018-02-12

    Prevention for aspiration pneumonia requires assessment of aspiration and adequate swallowing care. This randomized controlled trial aimed to investigate the effectiveness of ultrasound examination and recommendations for swallowing care for the reduction of aspiration and pharyngeal post-swallow residue as compared with standard swallowing care. Twenty-three participants were randomized to the intervention group and 23 to the control group. The intervention consisted of four ultrasound examinations during mealtimes and recommendations for swallowing care every 2 weeks during an 8 week period. No recommendations concerning swallowing care based on ultrasound examinations were provided to the control group. The frequency of aspiration or residue was defined as x/y × 100% when aspiration or residue were detected x times from y times concerning the total ultrasound measurements. The proportion of the residents with reduced frequency of aspiration which was detected by ultrasonography at eight weeks were 4.3% in the intervention group and 0% in the control group. The median reduction in the frequency of aspiration and residue in the intervention group was 31%, and that in the control group was 11%. In conclusion, swallowing care guided by frequent ultrasound examinations during mealtimes had a trend of reducing the frequency of aspiration and residue during an 8-week period in individuals relative to standard swallowing care alone.

  17. Ultrasound-Guided Versus Landmark-Guided Local Corticosteroid Injection for Carpal Tunnel Syndrome: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

    Science.gov (United States)

    Babaei-Ghazani, Arash; Roomizadeh, Peyman; Forogh, Bijan; Moeini-Taba, Seyed-Mohammad; Abedini, Amin; Kadkhodaie, Mona; Jahanjoo, Fateme; Eftekharsadat, Bina

    2018-04-01

    To review the literature and assess the comparative effectiveness of ultrasound-guided versus landmark-guided local corticosteroid injections in patients with carpal tunnel syndrome (CTS). Cochrane Central Register of Controlled Trials, MEDLINE (PubMed), Embase (Ovid), and Web of Science (from inception to February 1, 2017). Randomized controlled trials (RCTs) comparing ultrasound-guided injection with landmark-guided injection in patients with CTS were included. Two authors independently screened abstracts and full texts. The outcomes of interest were Symptom Severity Scale (SSS) and Functional Status Scale (FSS) scores of the Boston Carpal Tunnel Questionnaire and 4 electrodiagnostic parameters, including compound muscle action potential (CMAP), sensory nerve action potential (SNAP), distal motor latency (DML), and distal sensory latency (DSL). Overall, 569 abstracts were retrieved and checked for eligibility; finally, 3 RCTs were included (181 injected hands). Pooled analysis showed that ultrasound-guided injection was more effective in SSS improvement (mean difference [MD], -.46; 95% confidence interval [CI], -.59 to -.32; P.99), DML (MD, .05; 95% CI, -.30 to .39; P=.80), or DSL (MD, .00; 95% CI, -.65 to .65; P>.99). This review suggested that ultrasound-guided injection was more effective than landmark-guided injection in symptom severity improvement in patients with CTS; however, no significant differences were observed in functional status or electrodiagnostic improvements between the 2 methods. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  19. FD-OCT and IVUS intravascular imaging modalities in peripheral vasculature.

    Science.gov (United States)

    Spiliopoulos, S; Kitrou, P; Katsanos, K; Karnabatidis, D

    2017-02-01

    Intra-Vascular Ultra-Sound (IVUS) and Frequency Domain-Optical Coherence Tomography (FD-OCT), in vivo, intra-vascular, imaging modalities, widely used in the field of coronary disease, have been recently implemented in peripheral endovascular procedures, for procedural assessment, plaque characterization and determination of predictors of treatment outcomes. Their unique characteristics have also been used in order to provide additional features and improve the performance of re-entry devices and atherotomes. Areas covered: Present review focuses on available literature regarding these two promising imaging technologies in the peripheral vasculature, highlighting the added value produced by their use in endovascular therapy, their limitations and their utilization in new endovascular devices. Authors also provide their future perspective and the possible benefits in understanding vascular behavior and lesion characterization in peripheral endovascular interventions. Expert commentary: By providing both quantitative but also qualitative data on vessel and lesion morphology, intravascular imaging modalities offer a valid solution for endovascular treatment evaluation and outcome presentation homogeneity.

  20. Optical fiber laser ultrasound transmitter with electrospun composite for minimally invasive medical imaging

    Science.gov (United States)

    Poduval, Radhika; Noimark, Sacha; Colchester, Richard; Macdonald, Tom; Parkin, Ivan; Desjardins, Adrien; Papakonstantinou, Ioannis

    2017-07-01

    We report an optical fiber ultrasound transmitter with electrospun MWCNT-polymer composite, generating high-amplitude broadband ultrasound. They produced pressures in the range of conventional intravascular imaging transducers, and can be incorporated into catheters/needles for keyhole surgery

  1. Ultrasound-Guided Percutaneous Electrolysis and Eccentric Exercises for Subacromial Pain Syndrome: A Randomized Clinical Trial

    Science.gov (United States)

    Arias-Buría, José L.; Truyols-Domínguez, Sebastián; Valero-Alcaide, Raquel; Salom-Moreno, Jaime; Atín-Arratibel, María A.; Fernández-de-las-Peñas, César

    2015-01-01

    Objective. To compare effects of ultrasound- (US-) guided percutaneous electrolysis combined with an eccentric exercise program of the rotator cuff muscles in subacromial pain syndrome. Methods. Thirty-six patients were randomized and assigned into US-guided percutaneous electrolysis (n = 17) group or exercise (n = 19) group. Patients were asked to perform an eccentric exercise program of the rotator cuff muscles twice every day for 4 weeks. Participants assigned to US-guided percutaneous electrolysis group also received the application of galvanic current through acupuncture needle on each session once a week (total 4 sessions). Shoulder pain (NPRS) and disability (DASH) were assessed at baseline, after 2 sessions, and 1 week after the last session. Results. The ANOVA revealed significant Group∗Time interactions for shoulder pain and disability (all, P electrolysis combined with the eccentric exercises experienced greater improvement than those receiving eccentric exercise alone. Conclusions. US-guided percutaneous electrolysis combined with eccentric exercises resulted in small better outcomes at short term compared to when only eccentric exercises were applied in subacromial pain syndrome. The effect was statistically and clinically significant for shoulder pain but below minimal clinical difference for function. Future studies should investigate the long-term effects and potential placebo effect of this intervention. PMID:26649058

  2. Ultrasound-Guided Percutaneous Electrolysis and Eccentric Exercises for Subacromial Pain Syndrome: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    José L. Arias-Buría

    2015-01-01

    Full Text Available Objective. To compare effects of ultrasound- (US- guided percutaneous electrolysis combined with an eccentric exercise program of the rotator cuff muscles in subacromial pain syndrome. Methods. Thirty-six patients were randomized and assigned into US-guided percutaneous electrolysis (n=17 group or exercise (n=19 group. Patients were asked to perform an eccentric exercise program of the rotator cuff muscles twice every day for 4 weeks. Participants assigned to US-guided percutaneous electrolysis group also received the application of galvanic current through acupuncture needle on each session once a week (total 4 sessions. Shoulder pain (NPRS and disability (DASH were assessed at baseline, after 2 sessions, and 1 week after the last session. Results. The ANOVA revealed significant Group∗Time interactions for shoulder pain and disability (all, P<0.01: individuals receiving US-guided percutaneous electrolysis combined with the eccentric exercises experienced greater improvement than those receiving eccentric exercise alone. Conclusions. US-guided percutaneous electrolysis combined with eccentric exercises resulted in small better outcomes at short term compared to when only eccentric exercises were applied in subacromial pain syndrome. The effect was statistically and clinically significant for shoulder pain but below minimal clinical difference for function. Future studies should investigate the long-term effects and potential placebo effect of this intervention.

  3. A Randomized, Double-Blind, Placebo-Controlled, Phase 2b Study to Evaluate the Safety and Efficacy of Recombinant Human Soluble Thrombomodulin, ART-123, in Patients With Sepsis and Suspected Disseminated Intravascular Coagulation

    NARCIS (Netherlands)

    Vincent, Jean-Louis; Ramesh, Mayakonda K.; Ernest, David; Larosa, Steven P.; Pachl, Jan; Aikawa, Naoki; Hoste, Eric; Levy, Howard; Hirman, Joe; Levi, Marcel; Daga, Mradul; Kutsogiannis, Demetrios J.; Crowther, Mark; Bernard, Gordon R.; Devriendt, Jacques; Puigserver, Joan Vidal; Blanzaco, Daniel U.; Esmon, Charles T.; Parrillo, Joseph E.; Guzzi, Louis; Henderson, Seton J.; Pothirat, Chaicharn; Mehta, Parthiv; Fareed, Jawed; Talwar, Deepak; Tsuruta, Kazuhisa; Gorelick, Kenneth J.; Osawa, Yutaka; Kaul, Inder

    2013-01-01

    Objectives: To determine the safety and efficacy of recombinant thrombomodulin (ART-123) in patients with suspected sepsis-associated disseminated intravascular coagulation. Design: Phase 2b, international, multicenter, double-blind, randomized, placebo-controlled, parallel group, screening trial.

  4. Cross-sectional evaluation of electrical impedance myography and quantitative ultrasound for the assessment of Duchenne muscular dystrophy in a clinical trial setting.

    Science.gov (United States)

    Rutkove, Seward B; Geisbush, Tom R; Mijailovic, Aleksandar; Shklyar, Irina; Pasternak, Amy; Visyak, Nicole; Wu, Jim S; Zaidman, Craig; Darras, Basil T

    2014-07-01

    Electrical impedance myography and quantitative ultrasound are two noninvasive, painless, and effort-independent approaches for assessing neuromuscular disease. Both techniques have potential to serve as useful biomarkers in clinical trials in Duchenne muscular dystrophy. However, their comparative sensitivity to disease status and how they relate to one another are unknown. We performed a cross-sectional analysis of electrical impedance myography and quantitative ultrasound in 24 healthy boys and 24 with Duchenne muscular dystrophy, aged 2 to 14 years with trained research assistants performing all measurements. Three upper and three lower extremity muscles were studied unilaterally in each child, and the data averaged for each individual. Both electrical impedance myography and quantitative ultrasound differentiated healthy boys from those with Duchenne muscular dystrophy (P Duchenne muscular dystrophy boys (rho = 0.45; P = 0.029), whereas electrical impedance myography did not (rho = -0.31; P = 0.14). However, electrical impedance myography phase correlated with age in healthy boys (rho = 0.51; P = 0.012), whereas quantitative ultrasound did not (rho = -0.021; P = 0.92). In Duchenne muscular dystrophy boys, electrical impedance myography phase correlated with the North Star Ambulatory Assessment (rho = 0.65; P = 0.022); quantitative ultrasound revealed a near-significant association (rho = -0.56; P = 0.060). The two technologies trended toward a moderate correlation with one another in the Duchenne muscular dystrophy cohort but not in the healthy group (rho = -0.40; P = 0.054 and rho = -0.32; P = 0.13, respectively). Electrical impedance myography and quantitative ultrasound are complementary modalities for the assessment of boys with Duchenne muscular dystrophy; further study and application of these two modalities alone or in combination in a longitudinal fashion are warranted. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Obstetrical Ultrasound

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Obstetric Ultrasound Obstetric ultrasound uses sound waves to produce pictures of ... What are the limitations of Obstetrical Ultrasound Imaging? Obstetric ultrasound cannot identify all fetal abnormalities. Consequently, when ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces ... of page What are some common uses of the procedure? A transrectal ultrasound of the prostate gland ...

  10. INTRAVASCULAR ENDOTHELIOMA (ENDOTHELIOMA IN SITU, SYSTEMIC ENDOTHELIOMATOSIS).

    Science.gov (United States)

    HABER, H; HARRIS-JONES, J N; WELLS, A L

    1964-11-01

    A woman aged 48 years was found to be suffering from intravascular endothelioma. The initial clinical presentation was the presence of red, painless swellings in the skin of the lower limbs. The other clinical features, and the histological changes in skin biopsies, are described and compared with those in the two previously reported patients. It is suggested that the condition is analogous to the pre-invasive carcinomatous states.

  11. Effects of kinesiotherapy, ultrasound and electrotherapy in management of bilateral knee osteoarthritis: prospective clinical trial

    Directory of Open Access Journals (Sweden)

    Mascarin Naryana

    2012-09-01

    Full Text Available Abstract Background Although recent advances in knee osteoarthritis (OA treatment and evaluation were achieved, to the best of our knowledge, few studies have evaluated the longitudinal effect of therapeutic modalities on the functional exercise capacity of patients with knee OA. The purpose was to investigate the effects of kinesiotherapy and electrotherapy on functional exercise capacity, evaluated using the six-minute walk test (6-MWT in patients with bilateral knee OA. Secondary measurements included range of motion (ROM, severity of knee pain (VAS, and a measure of perceived health and physical function, evaluated using the Western Ontario and McMaster Universities (WOMAC Osteoarthritis Index. Methods A total of 40 women with bilateral knee OA were assigned to three groups: kinesiotherapy (KIN, n = 16, transcutaneous electrical nerve stimulation (TENS, n = 12, or ultrasound (US, n = 10. The groups underwent 12 weeks of intervention twice per week. The participants were subjected to the 6-MWT, ROM, VAS and WOMAC index. These tests were performed before and after the intervention. The study was focused on outpatients and was carried out at Universidade Estadual de Campinas, Brazil. Results At follow-up, the KIN and US groups had significantly higher 6-MWT distances (19.8 ± 21.7 and 14.1 ± 22.5%, respectively compared with their respective pre-intervention values. All treatments were effective for reducing pain and improving the WOMAC index. Conclusions We demonstrated that the 6-MWT is a tool that can be used to evaluate improvements in the functional exercise capacity of patients submitted to a clinical intervention.

  12. Ultrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.

    Science.gov (United States)

    Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F

    2016-01-01

    Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. After approval by our research ethics committee and written informed consent, adults undergoing distal upper arm surgery were randomized to either group I, ultrasound-guided single-injection infraclavicular block, or group A, ultrasound-guided double-injection axillary block. In group I, 30 mL of 1.5% mepivacaine was injected posterior to the axillary artery. In group A, 25 mL of 1.5% mepivacaine was injected posteromedial to the axillary artery, after which 5 mL was injected around the musculocutaneous nerve. Primary outcome was the rate of complete sensory block at 30 minutes. Secondary outcomes were the onset of sensory and motor blocks, surgical success rates, performance times, and incidence of complications. All outcomes were assessed by a blinded investigator. The noninferiority of the double-injection ultrasound-guided axillary block was considered if the limits of the 90% confidence intervals (CIs) were within a 10% margin of the rate of complete sensory block of the infraclavicular block. At 30 minutes, the rate of complete sensory block was 79% in group A (90% CI, 71%-85%) compared with 91% in group I (90% CI, 85%-95%); the upper limit of CI of group A is thus included in the established noninferiority margin of 10%. The rate of complete sensory block was lower in group A (proportion

  13. Ultrasound for Drug and Gene Delivery to the Brain

    OpenAIRE

    Hynynen, Kullervo

    2008-01-01

    Noninvasive, transient, and local image-guided blood-brain barrier disruption (BBBD) has been demonstrated with focused ultrasound exposure in animal models. Most studies have combined low pressure amplitude and low time average acoustic power burst sonications with intra-vascular injection of pre-formed micro-bubbles to produce BBBD without damage to the neurons. The BBB has been shown to be healed within a few hours after the exposure. The combination of focused ultrasound beams with MR ima...

  14. The Maastricht Ultrasound Shoulder pain trial (MUST): Ultrasound imaging as a diagnostic triage tool to improve management of patients with non-chronic shoulder pain in primary care

    OpenAIRE

    Ottenheijm, Ramon PG; Joore, Manuela A; Walenkamp, Geert HIM; Weijers, René E; Winkens, Bjorn; Cals, Jochen WL; de Bie, Rob A; Dinant, Geert-Jan

    2011-01-01

    Abstract Background Subacromial disorders are considered to be one of the most common pathologies affecting the shoulder. Optimal therapy for shoulder pain (SP) in primary care is yet unknown, since clinical history and physical examination do not provide decisive evidence as to the patho-anatomical origin of the symptoms. Optimal decision strategies can be furthered by applying ultrasound imaging (US), an accurate method in diagnosing SP, demonstrating a clear relationship between diagnosis ...

  15. Membrane design of an all-optical ultrasound receiver

    NARCIS (Netherlands)

    Leinders, S.M.; Dongen, K.W.A. van; Jong, N. de; Verweij, M.D.; Westerveld, W.J.; Urbach, H.P.; Neer, P.L.M.J. van; Pozo Torres, J.M.

    2013-01-01

    Ultrasound sensors such as piezoelectric transducers and CMUTs are successfully used for medical imaging. However, especially wiring of individual elements is difficult in the fabrication of small piezoelectric arrays, used in, e.g. the field of intravascular imaging. As an alternative, we designed

  16. Intravascular versus surface cooling for targeted temperature management after out-of-hospital cardiac arrest

    DEFF Research Database (Denmark)

    Glover, Guy W; Thomas, Richard M; Vamvakas, George

    2016-01-01

    BACKGROUND: Targeted temperature management is recommended after out-of-hospital cardiac arrest and may be achieved using a variety of cooling devices. This study was conducted to explore the performance and outcomes for intravascular versus surface devices for targeted temperature management after...... out-of-hospital cardiac arrest. METHOD: A retrospective analysis of data from the Targeted Temperature Management trial. N = 934. A total of 240 patients (26%) managed with intravascular versus 694 (74%) with surface devices. Devices were assessed for speed and precision during the induction......, maintenance and rewarming phases in addition to adverse events. All-cause mortality, as well as a composite of poor neurological function or death, as evaluated by the Cerebral Performance Category and modified Rankin scale were analysed. RESULTS: For patients managed at 33 °C there was no difference between...

  17. Efficacy of ultrasound-guided transversus abdominis plane block in laparoscopic hysterectomy. Clinical trial.

    Science.gov (United States)

    Guardabassi, D S; Lupi, S; Agejas, R; Allub, J M; García-Fornari, G

    2017-05-01

    Transversus abdominis plane block is a regional anaesthesia technique that has proven to be effective for postoperative pain reduction in different abdominal surgical procedures. This study evaluated its efficacy on post laparoscopic hysterectomy pain intensity and analgesic consumption. Randomized controlled trial which included 40 patients scheduled for laparoscopic hysterectomy, enrolled in 2 groups: transversus abdominis plane block+systemic analgesia (Group 1; n=20), versus systemic analgesia (Group 2; n=20). Opioid consumption within the first 24 postoperative hours, pain intensity scores at 60min, 2, 8 and 24h after surgery, adverse events related to systemic analgesia and time to hospital discharge were evaluated and registered. We found no differences between both groups in opioid consumption (10mg vs. 7mg; P=.2) and pain scores (NVS) within the first 24 postoperative hours, at 60min (3 vs. 5; P=.65), 120min (0 vs. 2; P=.15), 8 and 24h (0 vs. 0; P>.50) for the last 2 points in time analysed. Adverse events related to medication and time to hospital discharge showed similar results. Adding a transversus abdominis plane block technique to opioid PCA does not seem to improve postoperative pain management in laparoscopic hysterectomy. Patient preparation time and costs could be incremented and complications (although rare) related to the technique could appear. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Hypothesis: Disseminated Intravascular Inflammation as the Inflammatory Counterpart to Disseminated Intravascular Coagulation

    Science.gov (United States)

    Bull, Brian S.; Bull, Maureen H.

    1994-08-01

    We have identified a leukocyte activation syndrome that is occasionally associated with the transfusion of intraoperatively recovered erythrocytes. This syndrome appears to result from intravascular damage caused by leukocytes activated during the erythrocyte salvage process. We hypothesize that this syndrome is part of a larger disease grouping: disseminated intravascular inflammation (DII). DII is the analog of the coagulation disorder disseminated intravascular coagulation. In disseminated intravascular coagulation, the organ damage results from uncontrolled activation of the clotting pathway; in DII the damage is caused by leukocytes that have become activated by direct contact with bacteria or in rare instances-such as erythrocyte salvage-in the absence of bacteria and bacterial products. Recent studies of the hazards associated with intraoperative blood salvage indicate that activation of leukocytes can be achieved by exposure to activated platelets alone. If such activated leukocytes are reinfused along with the washed erythrocytes, widespread organ damage may result. The lung is the organ most severely affected by activated leukocytes. Adult respiratory distress syndrome is one outcome. It is likely that DII is a presently unrecognized pathophysiological process that complicates a variety of primary disease states and increases their lethality.

  19. Effects of arthroscopy-guided suprascapular nerve block combined with ultrasound-guided interscalene brachial plexus block for arthroscopic rotator cuff repair: a randomized controlled trial.

    Science.gov (United States)

    Lee, Jae Jun; Hwang, Jung-Taek; Kim, Do-Young; Lee, Sang-Soo; Hwang, Sung Mi; Lee, Na Rea; Kwak, Byung-Chan

    2017-07-01

    The aim of this study was to compare the pain relieving effect of ultrasound-guided interscalene brachial plexus block (ISB) combined with arthroscopy-guided suprascapular nerve block (SSNB) with that of ultrasound-guided ISB alone within the first 48 h after arthroscopic rotator cuff repair. Forty-eight patients with rotator cuff tears who had undergone arthroscopic rotator cuff repair were enrolled. The 24 patients in group 1 received ultrasound-guided ISB and arthroscopy-guided SSNB; the remaining 24 patients in group 2 underwent ultrasound-guided ISB alone. Visual analogue scale pain score and patient satisfaction score were checked at 1, 3, 6, 12, 18, 24, and 48 h post-operatively. Group 1 had a lower visual analogue scale pain score at 3, 6, 12, 18, 24, and 48 h post-operatively (1.7  6.0, 6.2 > 4.3, 6.4 > 5.1, 6.9 > 5.9, 7.9 > 7.1). Six patients in group 1 developed rebound pain twice, and the others in group 1 developed it once. All of the patients in group 2 had one rebound phenomenon each (p = 0.010). The mean timing of rebound pain in group 1 was later than that in group 2 (15.5 > 9.3 h, p  4.0, p = 0.001). Arthroscopy-guided SSNB combined with ultrasound-guided ISB resulted in lower visual analogue scale pain scores at 3-24 and 48 h post-operatively, and higher patient satisfaction scores at 6-36 h post-operatively with the attenuated rebound pain compared to scores in patients who received ultrasound-guided ISB alone after arthroscopic rotator cuff repair. The combined blocks may relieve post-operative pain more effectively than the single block within 48 h after arthroscopic cuff repair. Randomized controlled trial, Level I. ClinicalTrials.gov Identifier: NCT02424630.

  20. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    Science.gov (United States)

    Yamashita, Shuji; Narushima, Mitsunaga; Koshima, Isao; Miyamoto, Shimpei

    2017-01-01

    Background: Although supermicrosurgical anastomosis is a widely known reconstructive microsurgical technique, it is difficult to perform. To expand the clinical use of supermicrosurgery, we used hemi-intravascular stenting (hemi-IVaS), which is performed by inserting an intravascular stent into one side of the vessel. We conducted lymphaticovenular anastomosis, free perforator flap transfer, and fingertip replantation with supermicrosurgical anastomosis using hemi-IVaS technique and examined its usefulness. Methods: Between January 2013 and February 2015, 11 anastomoses in 11 cases of lymphaticovenular anastomosis for lymphedema patients, 14 anastomoses in 7 cases of free perforator flap transfer with supermicrosurgical perforator-to-perforator anastomosis, and 9 anastomoses in 5 cases of fingertip replantation were performed using hemi-IVaS. Time required for anastomosis and complications were examined. Flap survival rate was also examined in free perforator flap transfer cases and fingertip replantation cases. Results: In all cases, anastomoses were performed without complications such as inadvertent catching of the back wall of the vessel during the procedure or the need for reanastomoses. The average time required to complete the anastomosis was 16.4 ± 3.20 minutes using the hemi IVaS technique. All flaps survived in the supermicrosurgical perforator-to-perforator anastomosis as well as fingertip replantation cases. Conclusions: Hemi-IVaS could be a useful alternative to conventional intravascular stenting techniques and is also effective for supermicrosurgical perforator-to-perforator anastomosis. Further studies are needed to improve the success rate and to explore its other possible utilizations in supermicrosurgery. PMID:29263952

  1. Intravascular haemolysis: a potential missed diagnosis.

    Science.gov (United States)

    Sinclair, David; Briston, Philip; Rutland, Emma

    2002-01-01

    Raised serum bilirubin is a common finding as part of a routine "liver function test" profile. This case describes a patient with a raised serum bilirubin that was eventually found to be caused by intravascular haemolysis. The tests that confirmed the cause were instigated by clinical biochemistry staff but not before the patient had undergone unnecessary invasive procedures and had the diagnosis delayed by some time. The case is a reminder to biochemistry and haematology laboratories and clinical staff to investigate the possibility of haemolysis as well as hepatitis and Gilbert's disease as a cause of an isolated raised bilirubin.

  2. Intravascular imaging with a storage phosphor detector

    Science.gov (United States)

    Shikhaliev, Polad M.; Petrek, Peter; Matthews, Kenneth L., II; Fritz, Shannon G.; Bujenovic, L. Steven; Xu, Tong

    2010-05-01

    The aim of this study is to develop and test an intravascular positron imaging system based on a storage phosphor detector for imaging and detecting vulnerable plaques of human coronary arteries. The radiotracer F18-FDG accumulates in vulnerable plaques with inflammation of the overlying cap. The vulnerable plaques can, therefore, be imaged by recording positrons emitted from F18-FDG with a detector inserted into the artery. A prototype intravascular detector was constructed based on storage phosphor. The detector uses a flexible storage phosphor tube with 55 mm length, 2 mm diameter and 0.28 mm wall thickness. The intravascular detector is guided into the vessel using x-ray fluoroscopy and the accumulated x-ray signal must be erased prior to positron imaging. For this purpose, a light diffuser, 0.9 mm in diameter and 55 mm in length, was inserted into the detector tube. The light diffuser was connected to a laser source through a 2 m long optical fiber. The diffuser redirected the 0.38 W laser light to the inner surface of the phosphor detector to erase it. A heart phantom with 300 cm3 volume and three coronary arteries with 3.2 mm diameter and with several plaques was constructed. FDG solution with 0.5 µCi cm-3 activity concentration was filled in the heart and coronary arteries. The detector was inserted in a coronary artery and the signal from the plaques and surrounding background activity was recorded for 2 min. Then the phosphor detector was extracted and read out using a storage phosphor reader. The light diffuser erased the signal resulting from fluoroscopic exposure to level below that encountered during positron imaging. Vulnerable plaques with area activities higher than 1.2 nCi mm-2 were visualized by the detector. This activity is a factor of 10-20 lower than that expected in human vulnerable plaques. The detector was able to image the internal surface of the coronary vessels with 50 mm length and 360° circumference. Spatial resolution was 0

  3. Prehospital Ultrasound

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Full Text Available Ultrasound is a commonly used diagnostic tool in clinical conditions. With recent developments in technology, use of portable ultrasound devices has become feasible in prehospital settings. Many studies also proved the feasibility and accuracy of prehospital ultrasound. In this article, we focus on the use of prehospital ultrasound, with emphasis on trauma and chest ultrasound.

  4. Study Protocol. IDUS -- Instrumental delivery & ultrasound. A multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery

    LENUS (Irish Health Repository)

    Murphy, Deirdre J

    2012-09-13

    AbstractBackgroundInstrumental deliveries are commonly performed in the United Kingdom and Ireland, with rates of 12 – 17% in most centres. Knowing the exact position of the fetal head is a pre-requisite for safe instrumental delivery. Traditionally, diagnosis of the fetal head position is made on transvaginal digital examination by delineating the suture lines of the fetal skull and the fontanelles. However, the accuracy of transvaginal digital examination can be unreliable and varies between 20% and 75%. Failure to identify the correct fetal head position increases the likelihood of failed instrumental delivery with the additional morbidity of sequential use of instruments or second stage caesarean section. The use of ultrasound in determining the position of the fetal head has been explored but is not part of routine clinical practice.Methods\\/DesignA multi-centre randomised controlled trial is proposed. The study will take place in two large maternity units in Ireland with a combined annual birth rate of 13,500 deliveries. It will involve 450 nulliparous women undergoing instrumental delivery after 37 weeks gestation. The main outcome measure will be incorrect diagnosis of the fetal head position. A study involving 450 women will have 80% power to detect a 10% difference in the incidence of inaccurate diagnosis of the fetal head position with two-sided 5% alpha.DiscussionIt is both important and timely to evaluate the use of ultrasound to diagnose the fetal head position prior to instrumental delivery before routine use can be advocated. The overall aim is to reduce the incidence of incorrect diagnosis of the fetal head position prior to instrumental delivery and improve the safety of instrumental deliveries.Trial registrationCurrent Controlled Trials ISRCTN72230496

  5. Comparative study between ultrasound guided tap block and paravertebral block in upper abdominal surgeries. Randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Ruqaya M. Elsayed

    2017-01-01

    Conclusion: We concluded that ultrasound guided transversus abdominis plane block and thoracic paravertebral block were safe and effective anesthetic technique for upper abdominal surgery with longer and potent postoperative analgesia in thoracic paravertebral block than transversus abdominis block.

  6. Role of informed consent for intravascular contrast media

    International Nuclear Information System (INIS)

    Hopper, K.D.; Tyler, H.N. Jr.

    1988-01-01

    To evaluate the usefulness of different degrees of informed consent for intravascular contrast media, the authors divided 100 patients into four groups: (1) informed consent with no information on intravascular contrast media, (2) simple written informed consent that detailed common risks, (3) detailed written informed consent that detailed all known risks, and (4) MD informed consent, during which a radiologist discussed all known risks of intravascular contrast media. Physician counseling time for group 4 averaged 11.4 minutes. On a postprocedure test about the common complications and risk factors of intravascular contrast media, the average scores were: group 1, 38.4%; group 2, 68.2%; group 3, 63.2%; and group 4, 69.8%. There was no statistical difference between groups 2-4 on the postprocedure test. If informed consent is to be used prior to intravascular contrast media administration, a simple written consent detailing the common risks and risk factors appears to be the best method

  7. Comparison of utility of blood cultures from intravascular catheters and peripheral veins: a systematic review and decision analysis.

    Science.gov (United States)

    Falagas, Matthew E; Kazantzi, Maria S; Bliziotis, Ioannis A

    2008-01-01

    Blood cultures are sometimes obtained from intravascular catheters for convenience. However, there is controversy regarding this practice. The authors compared the diagnostic test characteristics of blood cultures obtained from intravascular catheters and peripheral veins. Relevant studies for inclusion in this review were identified through PubMed (January 1970-October 2005) and the Cochrane Central Register of Controlled Trials. Studies that reported clear definitions of true bacteraemia were included in the analysis. Two reviewers independently extracted the data. Six studies were included in the analysis, providing data for 2677 pairs of blood cultures obtained from an intravascular catheter and a peripheral venipuncture. A culture obtained from an intravascular catheter was found to be a diagnostic test for bacteraemia with better sensitivity (OR 1.85, 95 % CI 1.14-2.99, fixed effects model) and better negative predictive value (almost with statistical significance) (OR 1.55, 95 % CI 0.999-2.39, fixed effects model) but with less specificity (OR 0.33, 95 % CI 0.18-0.59, random effects model) and lower positive predictive value (OR 0.41, 95 % CI 0.23-0.76, random effects model) compared to a culture taken by peripheral venipuncture. In a group of 1000 patients, eight additional patients with true bacteraemia would be identified and 59 falsely diagnosed as having bacteraemia by a blood culture obtained from an intravascular catheter compared to results of the peripheral blood culture. Given the consequences of undertreating patients with bacteraemia, the authors believe that, based on the available evidence, at least one blood culture should be obtained from the intravascular catheter.

  8. Dutch randomized trial comparing standard catheter-directed thrombolysis versus Ultrasound-accElerated Thrombolysis for thromboembolic infrainguinal disease (DUET: design and rationale

    Directory of Open Access Journals (Sweden)

    Fioole Bram

    2011-01-01

    Full Text Available Abstract Background The use of thrombolytic therapy in the treatment of thrombosed infrainguinal native arteries and bypass grafts has increased over the years. Main limitation of this treatment modality, however, is the occurrence of bleeding complications. Low intensity ultrasound (US has been shown to accelerate enzymatic thrombolysis, thereby reducing therapy time. So far, no randomized trials have investigated the application of US-accelerated thrombolysis in the treatment of thrombosed infra-inguinal native arteries or bypass grafts. The DUET study (Dutch randomized trial comparing standard catheter-directed thrombolysis versus Ultrasound-accElerated Thrombolysis for thrombo-embolic infrainguinal disease is designed to assess whether US-accelerated thrombolysis will reduce therapy time significantly compared with standard catheter-directed thrombolysis. Methods/design Sixty adult patients with recently (between 1 and 7 weeks thrombosed infrainguinal native arteries or bypass grafts with acute limb ischemia class I or IIa, according to the Rutherford classification for acute ischemia, will be randomly allocated to either standard thrombolysis (group A or US-accelerated thrombolysis (group B. Patients will be recruited from 5 teaching hospitals in the Netherlands during a 2-year period. The primary endpoint is the duration of catheter-directed thrombolysis needed for uninterrupted flow in the thrombosed infrainguinal native artery or bypass graft, with outflow through at least 1 crural artery. Discussion The DUET study is a randomized controlled trial that will provide evidence of whether US-accelerated thrombolysis will significantly reduce therapy time in patients with recently thrombosed infrainguinal native arteries or bypass grafts, without an increase in complications. Trial registration Current Controlled Trials ISRCTN72676102

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound is most often performed to evaluate the: uterus cervix ovaries fallopian tubes bladder Pelvic ultrasound exams ... to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... special ultrasound technique that allows the physician to see and evaluate blood flow through arteries and veins ... development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . Ultrasound ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... What are the limitations of Pelvic Ultrasound Imaging? What is Pelvic Ultrasound Imaging? Ultrasound is safe and ... as the liver or kidneys. top of page What are some common uses of the procedure? In ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... What are the limitations of Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is ... in front of the rectum. top of page What are some common uses of the procedure? A ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a pelvic ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to ...

  18. Influence of ezetimibe in addition to high-dose atorvastatin therapy on plaque composition in patients with ST-segment elevation myocardial infarction assessed by serial Intravascular ultrasound with iMap: the OCTIVUS trial*

    DEFF Research Database (Denmark)

    Hougaard, Mikkel; Hansen, Henrik Steen; Thayssen, Per

    2017-01-01

    Background: The aim of this study was to examine the influence of ezetimibe in addition to atorvastatin on plaque composition in patients with first-time ST-segment Elevation Myocardial Infarction treated with primary percutaneous intervention. Methods: Eighty-seven patients were randomized ( 1: ...

  19. Randomized double-blind clinical trial comparing two anesthetic techniques for ultrasound-guided transvaginal follicular puncture.

    Science.gov (United States)

    Oliveira, Gilvandro Lins de; Serralheiro, Fernando Cesar; Fonseca, Fernando Luiz Affonso; Ribeiro, Onésimo Duarte; Adami, Fernando; Christofolini, Denise Maria; Bianco, Bianca; Barbosa, Caio Parente

    2016-01-01

    To compare the anesthetic techniques using propofol and fentanyl versus midazolam and remifentanil associated with a paracervical block with lidocaine in performing ultrasound-guided transvaginal oocyte aspiration. A randomized double-blind clinical trial (#RBR-8kqqxh) performed in 61 women submitted to assisted reproductive treatment. The patients were divided into two groups: anesthetic induction with 1mcg/kg of fentanyl associated with 1.5mg/kg of propofol (FP Group, n=32), in comparison with anesthetic induction using 0.075mg/kg of midazolam associated with 0.25mcg/kg/min of remifentanil, and paracervical block with 3mL of 2% lidocaine (MRPB Group, n=29). Main outcome measures: human reproduction outcomes, modified Aldrete-Kroulik index, hemodynamic parameters, and salivary cortisol. The results revealed a higher number of embryos formed in the FP Group (p50=2 versus 1; p=0.025), gestation rate two times higher in the FP Group (44.4% versus 22.2%; p=0.127), less time to reach AK=10 in the MRPB Group (p50=10 versus 2; panestesia com 1mcg/kg de fentanil associada com 1,5mg/kg de propofol (Grupo FP, n=32), em comparação com ao grupo submetido à indução da anestesia utilizando 0,075mg/kg de midazolam associada com 0,25mcg/kg/min de remifentanil, e bloqueio paracervical com 3mL de lidocaína a 2% (Grupo MRBP, n=29). Foram avaliados os resultados reprodutivos, índice modificado de Aldrete e Kroulik, parâmetros hemodinâmicos e cortisol salivar. Foi encontrado um número mais elevado de embriões formados no Grupo FP (p50=2 versus 1; p=0,025), taxa de gestação duas vezes mais elevada no Grupo FP (44,4% versus 22,2%; p=0,127), menos tempo para alcançar AK=10 no Grupo MRBP (p50=10 versus 2; panestesias (com fentanil e propofol, e com midazolam, remifentanil e bloqueio paracervical) ofereceram condições anestésicas satisfatórias na realização de procedimentos realizados em reprodução assistida, proporcionando conforto para o paciente e médico.

  20. No effect of bipolar interferential electrotherapy and pulsed ultrasound for soft tissue shoulder disorders: a randomised controlled trial

    Science.gov (United States)

    van der Heijden, G. J M G; Leffers, P.; Wolters, P.; Verheijden, J.; van Mameren, H.; Houben, J.; Bouter, L.; Knipschild, P.

    1999-01-01

    OBJECTIVE—To assess the efficacy of bipolar interferential electrotherapy (ET) and pulsed ultrasound (US) as adjuvants to exercise therapy for soft tissue shoulder disorders (SD).
METHODS—Randomised placebo controlled trial with a two by two factorial design plus an additional control group in 17 primary care physiotherapy practices in the south of the Netherlands. Patients with shoulder pain and/or restricted shoulder mobility, because of a soft tissue impairment without underlying specific or generalised condition, were enrolled if they had not recovered after six sessions of exercise therapy in two weeks. They were randomised to receive (1) active ET plus active US; (2) active ET plus dummy US; (3) dummy ET plus active US; (4) dummy ET plus dummy US; or (5) no adjuvants. Additionally, they received a maximum of 12 sessions of exercise therapy in six weeks. Measurements at baseline, 6 weeks and 3, 6, 9, and 12 months later were blinded for treatment. Outcome measures: recovery, functional status, chief complaint, pain, clinical status, and range of motion.
RESULTS—After written informed consent 180 patients were randomised: both the active treatments were given to 73 patients, both the dummy treatments to 72 patients, and 35 patients received no adjuvants. Prognosis of groups appeared similar at baseline. Blinding was successfully maintained. At six weeks seven patients (20%) without adjuvants reported very large improvement (including complete recovery), 17 (23%) and 16 (22%) with active and dummy ET, and 19 (26%) and 14 (19%) with active and dummy US. These proportions increased to about 40% at three months, but remained virtually stable thereafter. Up to 12 months follow up the 95% CI for differences between groups for all outcomes include zero.
CONCLUSION—Neither ET nor US prove to be effective as adjuvants to exercise therapy for soft tissue SD.

 PMID:10460185

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  2. Protection against high intravascular pressure in giraffe legs.

    Science.gov (United States)

    Petersen, Karin K; Hørlyck, Arne; Ostergaard, Kristine H; Andresen, Joergen; Broegger, Torbjoern; Skovgaard, Nini; Telinius, Niklas; Laher, Ismael; Bertelsen, Mads F; Grøndahl, Carsten; Smerup, Morten; Secher, Niels H; Brøndum, Emil; Hasenkam, John M; Wang, Tobias; Baandrup, Ulrik; Aalkjaer, Christian

    2013-11-01

    The high blood pressure in giraffe leg arteries renders giraffes vulnerable to edema. We investigated in 11 giraffes whether large and small arteries in the legs and the tight fascia protect leg capillaries. Ultrasound imaging of foreleg arteries in anesthetized giraffes and ex vivo examination revealed abrupt thickening of the arterial wall and a reduction of its internal diameter just below the elbow. At and distal to this narrowing, the artery constricted spontaneously and in response to norepinephrine and intravascular pressure recordings revealed a dynamic, viscous pressure drop along the artery. Histology of the isolated median artery confirmed dense sympathetic innervation at the narrowing. Structure and contractility of small arteries from muscular beds in the leg and neck were compared. The arteries from the legs demonstrated an increased media thickness-to-lumen diameter ratio, increased media volume, and increased numbers of smooth muscle cells per segment length and furthermore, they contracted more strongly than arteries from the neck (500 ± 49 vs. 318 ± 43 mmHg; n = 6 legs and neck, respectively). Finally, the transient increase in interstitial fluid pressure following injection of saline was 5.5 ± 1.7 times larger (n = 8) in the leg than in the neck. We conclude that 1) tissue compliance in the legs is low; 2) large arteries of the legs function as resistance arteries; and 3) structural adaptation of small muscle arteries allows them to develop an extraordinary tension. All three findings can contribute to protection of the capillaries in giraffe legs from a high arterial pressure.

  3. Model of distribution of dose for intravascular brachytherapy; Modelo de distribucion de dosis para braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Pirchio, Rosana; Signoretta, Catalina [Comision Nacional de Energia Atomica (CNEA), Buenos Aires (Argentina). Dosimetria de Radioaciones Ionizantes; Martin, Gabriela; Rivera, Elena; Bergoc, Rosa [Univeridad de Buenos Aires (Argentina). Facultad de Farmacia y Bioquimica. Lab. de Radioisotopos; Guzman, Luis [Instituto Cardiovascular de Buenos Aires (Argentina)

    2001-07-01

    In this work we present the radiation dose distributions for a theoretical model with Monte Carlo simulation, which was based on an experimental model developed for the study of the prevention of restenosis post-angioplasty employing intravascular brachytherapy. In the experimental model, the atherosclerotic plaques were induced in femoral arteries of male New Zealand rabbits through surgical intervention and later administration of cholesterol enriched diet. For the intravascular irradiation we employed a {sup 32} P source contained within the balloon used for the angioplasty. The radiation dose distributions were calculated using the Monte Carlo code MCNP4B according to a segment of a simulated artery. We studied the radiation dose distribution in the axial and radial directions for different thickness of the atherosclerotic plaques. The results will be correlated with the biologic effects observed by means of histological analysis of the irradiated arteries. (author)

  4. Intraoperative Ultrasound Guidance in Breast-Conserving Surgery Improves Cosmetic Outcomes and Patient Satisfaction: Results of a Multicenter Randomized Controlled Trial (COBALT).

    Science.gov (United States)

    Haloua, Max H; Volders, José H; Krekel, Nicole M A; Lopes Cardozo, Alexander M F; de Roos, Wifred K; de Widt-Levert, Louise M; van der Veen, Henk; Rijna, Herman; Bergers, Elisabeth; Jóźwiak, Katarzyna; Meijer, Sybren; van den Tol, Petrousjka

    2016-01-01

    Ultrasound-guided breast-conserving surgery (USS) results in a significant reduction in both margin involvement and excision volumes (COBALT trial). Objective. The aim of the present study was to determine whether USS also leads to improvements in cosmetic outcome and patient satisfaction when compared with standard palpation-guided surgery (PGS). A total of 134 patients with T1–T2 invasive breast cancer were included in the COBALT trial (NTR2579) and randomized to either USS (65 patients) or PGS (69 patients). Cosmetic outcomes were assessed by a three-member panel using computerized software Breast Cancer Conservative Treatment cosmetic results (BCCT.- core) and by patient self-evaluation, including patient satisfaction. Time points for follow-up were 3, 6, and 12 months after surgery. Overall cosmetic outcome and patient satisfaction were scored on a 4-point Likert scale (excellent, good, fair, or poor), and outcomes were analyzed using a multilevel, mixed effect, proportional odds model for ordinal responses. Ultrasound-guided breast-conserving surgery achieved better cosmetic outcomes, with 20 % excellence overall and only 6 % rated as poor, whereas 14 % of PGS outcomes were rated excellent and 13 % as poor. USS also had consistently lower odds for worse cosmetic outcomes (odds ratio 0.55, p = 0.067) than PGS. The chance of having a worse outcome was significantly increased by a larger lumpectomy volume (ptrend = 0.002); a volume [40 cc showed odds 2.78-fold higher for a worse outcome than a volume B40 cc. USS resulted in higher patient satisfaction compared with PGS. Ultrasound-guided breast-conserving surgery achieved better overall cosmetic outcomes and patient satisfaction than PGS. Lumpectomy volumes[40 cc resulted in significantly worse cosmetic outcomes.

  5. Intravascular ultrasonic-photoacoustic (IVUP) endoscope with 2.2-mm diameter catheter for medical imaging.

    Science.gov (United States)

    Bui, Nhat Quang; Hlaing, Kyu Kyu; Nguyen, Van Phuc; Nguyen, Trung Hau; Oh, Yun-Ok; Fan, Xiao Feng; Lee, Yong Wook; Nam, Seung Yun; Kang, Hyun Wook; Oh, Junghwan

    2015-10-01

    Intravascular ultrasound (IVUS) imaging is extremely important for detection and characterization of high-risk atherosclerotic plaques as well as gastrointestinal diseases. Recently, intravascular photoacoustic (IVPA) imaging has been used to differentiate the composition of biological tissues with high optical contrast and ultrasonic resolution. The combination of these imaging techniques could provide morphological information and molecular screening to characterize abnormal tissues, which would help physicians to ensure vital therapeutic value and prognostic significance for patients before commencing therapy. In this study, integration of a high-frequency IVUS imaging catheter (45MHz, single-element, unfocused, 0.7mm in diameter) with a multi-mode optical fiber (0.6mm in core diameter, 0.22 NA), an integrated intravascular ultrasonic-photoacoustic (IVUP) imaging catheter, was developed to provide spatial and functional information on light distribution in a turbid sample. Simultaneously, IVUS imaging was co-registered to IVPA imaging to construct 3D volumetric sample images. In a phantom study, a polyvinyl alcohol (PVA) tissue-mimicking arterial vessel phantom with indocyanine green (ICG) and methylene blue (MB) inclusion was used to demonstrate the feasibility of mapping the biological dyes, which are used in cardiovascular and cancer diagnostics. For the ex vivo study, an excised sample of pig intestine with ICG was utilized to target the biomarkers present in the gastrointestinal tumors or the atherosclerotic plaques with the proposed hybrid technique. The results indicated that IVUP endoscope with the 2.2-mm diameter catheter could be a useful tool for medical imaging. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Non-atherosclerotic spontaneous coronary artery dissection revascularized by intravascular ultrasonography-guided fenestration with cutting balloon angioplasty.

    Science.gov (United States)

    Ito, Tsuyoshi; Shintani, Yasuhiro; Ichihashi, Taku; Fujita, Hiroshi; Ohte, Nobuyuki

    2017-07-01

    A 46-year-old woman was referred to our hospital due to chest pain. Twelve-lead electrocardiogram revealed ST-segment elevation suggesting acute myocardial infarction. Emergent coronary angiography showed diffuse narrowing and occlusion in the middle to distal left anterior descending artery (LAD). To investigate the cause of occlusion, an intravascular ultrasound (IVUS) examination was performed and we diagnosed spontaneous coronary artery dissection (SCAD) as the cause of occlusion. After a cutting balloon was dilated at the distal LAD, coronary flow recovered. IVUS-guided angioplasty with cutting balloon could be a choice of treatment in SCAD patients who need revascularization.

  7. Intravascular catheter-related bloodstream infection.

    Science.gov (United States)

    Shah, Harshal; Bosch, Wendelyn; Thompson, Kristine M; Hellinger, Walter C

    2013-07-01

    Intravascular catheters required for the care of many hospitalized patients can give rise to bloodstream infection, a complication of care that has occurred most frequently in intensive care unit (ICU) settings. Elucidation of the pathogenesis of catheter-related bloodstream infections (CRBSIs) has guided development of effective diagnostic, management, and prevention strategies. When CRBSIs occur in the ICU, physicians must be prepared to recognize and treat them. Prevention of these infections requires careful attention to optimal catheter selection, insertion and maintenance, and to removal of catheters when they are no longer needed. This review provides a succinct summary of the epidemiology, pathogenesis, and microbiology of CRBSIs and a review of current guidance for the diagnosis, management, and prevention of these infections.

  8. Death following intravascular administration of contrast media

    International Nuclear Information System (INIS)

    Shehadi, W.H.

    1985-01-01

    Adverse reactions to intravascularly administered contrast media preceding death and the autopsy findings in 44 patients are presented. There is a wide scatter of the age distribution of fatal reactions. The highest incidence is in the 50-70 year age group. Similar observations were obtained from the 405 deaths due to contrast media reported to the Food and Drug Administration of the United States. In the same age group the number of reactions is highest, likewise the autopsy findings. The predominant autopsy findings are pulmonary edema, congestion and hemorrhage; arteriosclerosis, both general and coronary. In the younger age group the autopsy findings are limited mostly to the respiratory tract. Fatal reactions to contrast media occur often without warning and most deaths occur within 15 min to 6 hours. Reactions to contrast media occur without relation to sex or age. (orig.)

  9. Quinine-Induced Disseminated Intravascular Coagulation

    Directory of Open Access Journals (Sweden)

    Firas Abed

    2016-01-01

    Full Text Available Every drug comes with some side effect. It is the benefit/risk ratio that determines the medical use of the drug. Quinine, a known antimalarial drug, has been used for nocturnal leg cramps since the 1930s; it is associated with severe life-threatening hematological and cardiovascular side effects. Disseminated intravascular coagulation (DIC, albeit rare, is a known coagulopathy associated with Quinine. It is imperative to inquire about the Quinine intake in medication history in patients with coagulopathy, as most patients still consider it a harmless home remedy for nocturnal leg cramps. In this report, we present a case of coagulopathy in a middle-aged woman, who gave a history of taking Quinine for nocturnal leg cramps, as her home remedy. Early identification of the offending agent led to the diagnosis, prompt discontinuation of the medication, and complete recovery and prevented the future possibility of recurrence.

  10. Chronic Disseminated Intravascular Coagulation: A Case Report

    Directory of Open Access Journals (Sweden)

    Md Abul Kalam Azad

    2009-11-01

    Full Text Available In health there is a balance between the coagulation and anti-coagulation systems, but in disseminated intravascular coagulation (DIC the coagulation mechanism is activated inappropriately and in a diffuse way. This may lead to thrombosis, but more often haemorrhage occurs when the clotting factors are exhausted. DIC may present as acute, subacute, and rarely chronic form. Here we present a case of chronic DIC following pelvic inflammatory disease (PID as a consequence of repeated menstruation regulation (MR. We treated her with fresh frozen plasma, fresh blood, doxycycline with significant clinical improvement.DOI: 10.3329/bsmmuj.v1i1.3696 BSMMU J 2008; 1(1: 33-34

  11. Ventricular metastasis resulting in disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Davis Ian D

    2005-05-01

    Full Text Available Abstract Background Disseminated Intravascular Coagulation (DIC complicates up to 7% of malignancies, the commonest solid organ association being adenocarcinoma. Transitional Cell Carcinoma (TCC has rarely been associated with DIC. Case presentation A 74-year-old woman with TCC bladder and DIC was found to have a cardiac lesion suspicious for metastatic disease. The DIC improved with infusion of plasma and administration of Vitamin K, however the cardiac lesion was deemed inoperable and chemotherapy inappropriate; given the patients functional status. We postulate that direct activation of the coagulation cascade by the intraventricular metastasis probably triggered the coagulopathy in this patient. Conclusion Cardiac metastases should be considered in cancer patients with otherwise unexplained DIC. This may influence treatment choices.

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... women, a pelvic ultrasound exam can help identify: kidney stones bladder tumors other disorders of the urinary bladder ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  15. Review on ultrasound measurement of bladder or detrusor wall thickness in women: techniques, diagnostic utility, and use in clinical trials

    NARCIS (Netherlands)

    Oelke, Matthias; Khullar, Vik; Wijkstra, Hessel

    2013-01-01

    To provide a narrative review of literature evaluating ultrasound techniques for the measurement of bladder wall hypertrophy in women as an alternative to invasive urodynamic assessment for the diagnosis of lower urinary tract symptoms (LUTS). A literature review was performed using PubMed and all

  16. The suprasacral parallel shift vs lumbar plexus blockade with ultrasound guidance in healthy volunteers - a randomised controlled trial

    DEFF Research Database (Denmark)

    Bendtsen, T F; Pedersen, E M; Haroutounian, S

    2014-01-01

    Surgical anaesthesia with haemodynamic stability and opioid-free analgesia in fragile patients can theoretically be provided with lumbosacral plexus blockade. We compared a novel ultrasound-guided suprasacral technique for blockade of the lumbar plexus and the lumbosacral trunk with ultrasound-gu...... and zero with the lumbar plexus block (p techniques are effective for blockade of the terminal nerves of the lumbar plexus. The suprasacral parallel shift technique is 50% effective for blockade of the lumbosacral trunk.......Surgical anaesthesia with haemodynamic stability and opioid-free analgesia in fragile patients can theoretically be provided with lumbosacral plexus blockade. We compared a novel ultrasound-guided suprasacral technique for blockade of the lumbar plexus and the lumbosacral trunk with ultrasound......-guided blockade of the lumbar plexus. The objective was to investigate whether the suprasacral technique is equally effective for anaesthesia of the terminal lumbar plexus nerves compared with a lumbar plexus block, and more effective for anaesthesia of the lumbosacral trunk. Twenty volunteers were included...

  17. Education and Propagation of Intravascular Surgery in Okinawa

    Science.gov (United States)

    Harakuni, T.; Hyodo, A.; Shingaki, T.; Kugai, M.; Kinjyo, T.; Kinjyo, T.; Tsuchida, H.; Sugimoto, K.; Yoshii, Y.

    2004-01-01

    Summary Okinawa is an island located on the southwest edge of the Japanese Islands in which about 1,300,000 people live, and is an area where self-conclusion type medical treatment is desired. In this area, intravascular surgery was only performed for several cases per year until 1998. From May 1999, intravascular surgery started being performed in earnest, and 140 or more cases of intravascular surgery per year were performed in 2002. In the meantime, various measures for the propagation and development of intravascular surgery that we undertook led to the increase in the number of cases. As a result, the choice of medical treatment has increased by propagating these medical treatments, and it seems that this has contributed to the welfare of the people of Okinawa. PMID:20587285

  18. Intravascular photoacoustic detection of vulnerable plaque based on constituent selected imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Jian; Xing Da, E-mail: xingda@scnu.edu.cn [MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631 (China)

    2011-01-01

    Atherosclerosis, a disease of the large arteries, is the primary cause of heart disease and stroke. Over decades, atherosclerosis is characterized by thickening of the walls of the arteries, only advanced atherosclerotic disease could be observed. Photoacoustic imaging is a hybrid imaging technique that combines the advantages of high spatial resolution of ultrasound with contrast of optical absorption. In this paper, we present an intravascular photoacoustic (IVPA) imaging system to characterize vulnerable plaques by using the optical absorption contrast between different constituents. Epidemiological studies have revealed several important plaque constituents associated with early atherosclerosis, such as macrophage, cholesterol, lipid, calcification, and so on. We chose a section of lipid rich atherosclerosis artery and a section of normal artery as the phantom. Two IVPA images of them are given to show the difference between sick and normal. As a new method of detecting vulnerable plaque, IVPA constituents imaging will provide more details for diagnosis that offer an enticing prospect in early detecting of atherosclerosis.

  19. Prediction of postpercutaneous coronary intervention myocardial infarction: insights from intravascular imaging, coronary flow, and biomarker evaluation.

    Science.gov (United States)

    Hoole, Stephen P; Hernández-Sánchez, Jules; Brown, Adam J; Giblett, Joel P; Bennett, Martin R; West, Nick E J

    2018-05-01

    Percutaneous coronary intervention-induced myocardial infarction (PMI) has prognostic significance. Identifying patients at high risk for PMI is desirable as it may alter strategy and facilitate early preventative therapy. We therefore sought to establish whether preprocedural demographic, interventional (plaque characteristics and coronary microcirculatory function), and inflammatory, endothelial damage, and platelet-derived biomarker data could predict the risk of PMI. We performed target vessel pressure wire to assess fractional flow reserve, index of microcirculatory resistance (IMR) and coronary flow reserve, plaque characterization by virtual histology intravascular ultrasound, and assayed peripheral biomarkers before uncomplicated PCI in 88 patients. We then analyzed post-PCI cardiac troponin level to adjudicate PMI based on the third universal definition of myocardial infarction. Overall incidence of PMI was 27%. Women [10/15 (66%) vs. 14/73 (19%), PPMI. Preprocedural coronary flow reserve was lower in individuals with a subsequent PMI (1.8±1.2 vs. 2.1±1.3. P=0.03), and patients with higher pre-PCI IMR were more likely to sustain PMI [IMR>22: 10/23 (44%) vs. ≤22: 14/65 (22%), P=0.04], although neither was predictive after multivariate analysis. Plaque characterization by virtual histology intravascular ultrasound did not discriminate those at risk of PMI. However, peripheral venous interleukin (IL)-18 and IL-8 levels were independently negatively and positively associated with PMI, respectively. Women and those with low BMI, particularly when associated with high IL-8 and low IL-18 levels, appear to be at increased risk of PMI.

  20. Lung cancer diagnosis and staging with endobronchial ultrasound-guided transbronchial needle aspiration compared with conventional approaches: an open-label, pragmatic, randomised controlled trial.

    Science.gov (United States)

    Navani, Neal; Nankivell, Matthew; Lawrence, David R; Lock, Sara; Makker, Himender; Baldwin, David R; Stephens, Richard J; Parmar, Mahesh K; Spiro, Stephen G; Morris, Stephen; Janes, Sam M

    2015-04-01

    The diagnosis and staging of lung cancer is an important process that identifies treatment options and guides disease prognosis. We aimed to assess endobronchial ultrasound-guided transbronchial needle aspiration as an initial investigation technique for patients with suspected lung cancer. In this open-label, multicentre, pragmatic, randomised controlled trial, we recruited patients who had undergone a CT scan and had suspected stage I to IIIA lung cancer, from six UK centres and randomly assigned them to either endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) or conventional diagnosis and staging (CDS), for further investigation and staging. If a target node could not be accessed by EBUS-TBNA, then endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) was allowed as an alternative procedure. Randomisation was stratified according to the presence of mediastinal lymph nodes measuring 1 cm or more in the short axis and by recruiting centre. We used a telephone randomisation method with permuted blocks of four generated by a computer. Because of the nature of the intervention, masking of participants and consenting investigators was not possible. The primary endpoint was the time-to-treatment decision after completion of the diagnostic and staging investigations and analysis was by intention-to-diagnose. This trial is registered with ClinicalTrials.gov, number NCT00652769. Between June 10, 2008, and July 4, 2011, we randomly allocated 133 patients to treatment: 66 to EBUS-TBNA and 67 to CDS (one later withdrew consent). Two patients from the EBUS-TBNA group underwent EUS-FNA. The median time to treatment decision was shorter with EBUS-TBNA (14 days; 95% CI 14-15) than with CDS (29 days; 23-35) resulting in a hazard ratio of 1·98, (1·39-2·82, plung cancer, because it reduces the time to treatment decision compared with conventional diagnosis and staging techniques. UK Medical Research Council. Copyright © 2015 Navani et al. Open

  1. Imminent Cardiac Risk Assessment via Optical Intravascular Biochemical Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wetzel, D.; Wetzel, L; Wetzel, M; Lodder, R

    2009-01-01

    still the first line of defense. However, with the fidelity of 64-slice CT imaging, this technique has recently become an option when the patient presents with symptoms of reduced arterial flow. Single photon emission computerized tomography (SPECT) treadmill exercise testing is a standard non-invasive test for decreased perfusion of heart muscle, but is time consuming and not suited for emergent evaluation. Once the invasive clinical option of catherization is chosen, this provides the opportunity for intravascular ultrasound (IVUS) imaging. As the probe is pulled through the artery, the diameter at different parts is measurable, and monochrome contrast in the constricted area reveals the presence of tissue with a different ultrasonic response. Also, via an optical catheter with a fiber-optic conductor, the possibly of spectroscopic analysis of arterial walls is now a reality. In this case, the optical transducer is coupled to a near-infrared spectrometer. Revealing the arterial chemical health means that plaque vulnerability and imminent risk could be assessed by the physician. The classical emergency use of catherization involves a contrast agent and dynamic X-ray imaging to locate the constriction, determine its severity, and possibly perform angioplasty, and stent placement.

  2. Effects of placebo-controlled continuous and pulsed ultrasound treatments on carpal tunnel syndrome: a randomized trial

    Directory of Open Access Journals (Sweden)

    Onur Armagan

    2014-08-01

    Full Text Available OBJECTIVE: The aim of this placebo-controlled study was to evaluate the effects of pulsed and continuous ultrasound treatments combined with splint therapy on patients with mild and moderate idiopathic carpal tunnel syndrome. METHODS: The study included 46 carpal tunnel syndrome patients who were randomly divided into 3 groups. The first group (n = 15 received a 0 W/cm2 ultrasound treatment (placebo; the second group (n = 16 received a 1.0 W/cm2 continuous ultrasound treatment and the third group (n = 15 received a 1.0 W/cm2 1:4 pulsed ultrasound treatment 5 days a week for a total of 15 sessions. All patients also wore night splints during treatment period. Pre-treatment and post-treatment Visual Analogue Scale, Symptom Severity Scale and Functional Status Scale scores, median nerve motor conduction velocity and distal latency and sensory conduction velocities of the median nerve in the 2nd finger and palm were compared. Clinicaltrials.gov: NCT02054247. RESULTS: There were significant improvements in all groups in terms of the post-treatment Functional Status Scale score (p<0.05 for all groups, Symptom Severity Scale score (first group: p<0.05, second group: p<0.01, third group: p<0.001 and Visual Analogue Scale score (first and third groups: p<0.01, second group: p<0.001. Sensory conduction velocities improved in the second and third groups (p<0.01. Distal latency in the 2nd finger showed improvement only in the third group (p<0.01 and action potential latency in the palm improved only in the second group (p<0.05. CONCLUSION: The results of this study suggest that splinting therapy combined with placebo and pulsed or continuous ultrasound have similar effects on clinical improvement. Patients treated with continuous and pulsed ultrasound showed electrophysiological improvement; however, the results were not superior to those of the placebo.

  3. Ultrasound combined transcutaneous electrical nerve stimulation (UltraTENS) versus phonophoresis of piroxicam (PhP) in symptomatic knee osteoarthritis: A randomized double-blind, controlled trial.

    Science.gov (United States)

    Boonhong, Jariya; Suntornpiyapan, Phitsanu

    2018-02-02

    Ultrasound combined with transcutaneous electrical nerve stimulation (UltraTENS) and phonophoresis of piroxicam (PhP) are combined modality therapy that frequently used in musculoskeletal pain including knee osteoarthritis (OA). But it is lack of a good clinical trial to prove and compare their effects. To compare the effects of UltraTENS with PhP on mild to moderate degree of symptomatic knee OA. Sixty-one patients (55 women), mean age of 63.4 ± 8.1 y, 50-90 mm VAS of knee pain and Kellgren-Lawrence score of grade I-III were randomly allocated into UltraTENS and PhP (N = 31 and 30, respectively). The UltraTENS group received a combined ultrasound with TENS program and a non-drug gel, whereas the PhP group got an ultrasound program with piroxicam gel and sham TENS. All patients were treated for a total of 10 sessions, consisting of five times per week and 10 min per session. Before and after treatment, patients were evaluated knee pain by using the 100-mm VAS and functional performance by Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index. The UltraTENS and PhP groups experienced considerable improvement in both VAS and total WOMAC scores post-treatment (PPhP had better VAS of pain and WOMAC scores but no statistical significance. Results show that UltraTENS and PhP were effective for relieving pain and improve functionality knee OA without significant differences between their effects.

  4. Gamma probe and ultrasound guided fine needle aspiration cytology of the sentinel node (GULF) trial - overview of the literature, pilot and study protocol.

    Science.gov (United States)

    Oude Ophuis, Charlotte M C; Koppert, Lisa B; de Monyé, Cécile; van Deurzen, Carolien H M; Koljenović, Senada; van Akkooi, Alexander C J; Verhoef, Cornelis; Grünhagen, Dirk J

    2017-04-12

    Sentinel node (SN) biopsy (SNB) detects clinically occult metastases of breast cancer and melanoma in 20-30%. Wound infections, seroma and lymph edema occur in up to 10%. Targeted ultrasound (US) of the SN, (with fine needle aspiration cytology (FNAC) if appropriate) has been investigated as a minimally invasive alternative, but reported sensitivity rates are too low to replace SNB. Our hypothesis is that the use of a handheld gamma probe concomitant with US may improve sensitivity. Our aim is to provide an overview of the current literature on preoperative nodal staging of clinical N0 melanoma patients, report on a pilot, and present a study protocol for a minimally invasive alternative to the SNB: Gamma probe and Ultrasound guided Fine needle aspiration cytology of the sentinel node (GULF trial). The GULF trial is a multicenter open single arm observational trial. Newly diagnosed cT1b-4N0M0 cutaneous melanoma or cT1-3N0M0 breast cancer patients, aged >18 years, presenting for SNB are eligible. 120 patients will be included for preoperative targeted gamma probe guided US and FNAC of the SN. Afterwards all patients proceed to surgical SNB. Primary endpoint is the sensitivity of FNAC. Secondary endpoints include SN identification rate and the histopathological compatibility of Core Needle Biopsy and FNAC vs. SNB. Secondary endpoints were investigated in a pilot with 10 FNACs and marker placements, and 10 FNACs combined with Core Needle Biopsy. A pilot in 20 patients showed that SN identification rate was 90%, supporting the feasibility of this technique. There is broad experience with US (in combination with FNAC) prior to SNB, but sensitivity and specificity are too low to completely abandon SNB. Promising alternative techniques potentially will replace SNB in the future but more evidence is needed in the form of prospective studies. Accurate identification of the SN for US-FNAC has been proven feasible in our pilot. When adequate sensitivity can be reached, US

  5. Intravascular Large B-Cell Lymphoma

    Directory of Open Access Journals (Sweden)

    Maria S. Khan MD, FACP

    2014-03-01

    Full Text Available Case Presentation . A 69-year-old Hispanic male, with a past history of diabetes and coronary disease, was admitted for fever, diarrhea, and confusion of 4 weeks duration. Physical examination showed a disoriented patient with multiple ecchymoses, possible ascites, and bilateral scrotal swelling. Hemoglobin was 6.7, prothrombin time (PT 21.4 seconds with international normalized ratio 2.1, partial thromboplastin time (PTT 55.6 seconds, fibrin split 10 µg/L, and lactate dehydrogenase (LDH 1231 IU/L. Except for a positive DNA test for Epstein–Barr virus (EBV infection, extensive diagnostic workup for infections, malignancy, or a neurological cause was negative. Mixing studies revealed a nonspecific inhibitor of PT and PTT but Factor VIII levels were normal. The patient was empirically treated with antibiotics but developed hypotension and died on day 27 of admission. At autopsy, patient was found to have intravascular diffuse large B-cell lymphoma involving skin, testes, lung, and muscles. The malignant cells were positive for CD20, CD791, Mum-1, and Pax-5 and negative for CD3, CD5, CD10, CD30, and Bcl-6. The malignant cells were 100% positive for Ki-67. Discussion . Intravascular large cell B-cell lymphoma (IVLBCL is rare form of diffuse large B-cell lymphoma and tends to proliferate within small blood vessels, particularly capillaries and postcapillary venules. The cause of its affinity for vascular bed remains unknown. In many reports, IVLBCL was associated with HIV, HHV8, and EBV infections. The fact that our case showed evidence of EBV infection lends support to the association of this diagnosis to viral illness. The available literature on this subject is scant, and in many cases, the diagnosis was made only at autopsy. The typical presentation of this disorder is with B symptoms, progressive neurologic deficits, and skin findings. Bone marrow, spleen, and liver are involved in a minority of patients. Nearly all patients have elevated LDH

  6. Ultrasound-guided intermediate cervical plexus block and perivascular local anesthetic infiltration for carotid endarterectomy : A randomized controlled trial.

    Science.gov (United States)

    Seidel, R; Zukowski, K; Wree, A; Schulze, M

    2016-12-01

    Ultrasound-guided blocks of the cervical plexus are established anesthetic procedures for carotid endarterectomy. This randomized, double-blind, placebo-controlled study tested the hypothesis that an additional ultrasound-guided periarterial injection of local anesthetic leads to a lower frequency of periarterial supplementation by the surgeon. A total of 40 patients were randomly assigned to 1 of 2 groups. In both groups an ultrasound-guided intermediate cervical plexus block (20 ml of 0.75 % ropivacaine) at the level of the fourth cervical vertebra was performed. In a second step, the needle was inserted from posterolateral to anteromedial (in-plane technique) relative to the internal carotid artery and then, depending on the randomized group assignment, 5 ml of 0.75 % ropivacaine (group 2) or 5 ml of 0.9 % saline (group 1) was injected. The parameters investigated included the need for supplementation, patient comfort, the incidence of side effects and circulatory changes. The two groups did not significantly differ (p = 0.459) in terms of the need for intraoperative supplementation with 1 % prilocaine with a mean (range) in group 2 of 4.9 ml (0-20 ml), in group 1 of 3.7 ml (0-16 ml) and patient comfort (p = 0.144). In addition, a trend towards a higher complication rate was observed in group 2. For ultrasound-guided intermediate blocks of the cervical plexus, an additional periarterial infiltration showed no advantage. Abandoning this technique leads to a relevant simplification of the blocking technique and tends to reduce block-related side effects.

  7. Physical function of the upper limb after breast cancer surgery. Results from the SOUND (Sentinel node vs. Observation after axillary Ultra-souND) trial.

    Science.gov (United States)

    Gentilini, O; Botteri, E; Dadda, P; Sangalli, C; Boccardo, C; Peradze, N; Ghisini, R; Galimberti, V; Veronesi, P; Luini, A; Cassano, E; Viale, G; Veronesi, U

    2016-05-01

    The SOUND (Sentinel node vs. Observation after axillary Ultra-souND) trial is an ongoing prospective randomized study comparing sentinel node biopsy vs. no axillary surgical staging in patients with small breast cancer and negative pre-operative ultra-sound of the axilla. The first 180 recruited patients were administered the QuickDASH (Disability Arm and Shoulder) questionnaire at different time points (before surgery, 1 week, 6 months and 1 year after surgery) to evaluate the physical function of the ipsilateral upper limb, The QuickDASH score ranges from 0 (no disability) to 100 (complete disability). 176 patients were available for analysis (94 in SNB arm and 82 in observation arm). The two groups were comparable with respect to age, tumor characteristics and treatments. Pre-surgery score values were 3.0% and 2.7% in the SNB arm and observation arm, respectively (P = 0.730). One week after surgery, the score increased to 24.0% in the SNB arm and 10.6% in the observation arm (P disability in the early post-operative period compared to patients who did not. The avoidance of SNB might translate into a considerable reduction of physical and emotional distress. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Web-based accurate measurements of carotid lumen diameter and stenosis severity: An ultrasound-based clinical tool for stroke risk assessment during multicenter clinical trials.

    Science.gov (United States)

    Saba, Luca; Banchhor, Sumit K; Londhe, Narendra D; Araki, Tadashi; Laird, John R; Gupta, Ajay; Nicolaides, Andrew; Suri, Jasjit S

    2017-12-01

    This pilot study presents a completely automated, novel, smart, cloud-based, point-of-care system for (a) carotid lumen diameter (LD); (b) stenosis severity index (SSI) and (c) total lumen area (TLA) measurement using B-mode ultrasound. The proposed system was (i) validated against manual reading taken by the Neurologist and (ii) benchmarked against the commercially available system. One hundred patients (73 M/27 F, mean age: 68 ± 11 years), institutional review board approved, written informed consent, consisted of left/right common carotid artery (200 ultrasound scans) were acquired using a 7.5-MHz linear transducer. The measured mean LD for left and right carotids were (in mm): (i) for proposed system (6.49 ± 1.77, 6.66 ± 1.70); and (ii) for manual (6.29 ± 1.79, 6.45 ± 1.63), respectively and coefficient of correlation between cloud-based automated against manual were 0.98 (P cloud-based system was: 1.0. Four statistical tests such as: Two-tailed z-test, Mann-Whitney test, Kolmogorov-Smirnov (KS) and one-way ANOVA were performed to demonstrate consistency and reliability. The proposed system is reliable, accurate, fast, completely automated, anytime-anywhere solution for multi-center clinical trials and routine vascular screening. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. [Intravascular lymphomatosis. A report of three cases].

    Science.gov (United States)

    Menéndez Calderón, M J; Seguí Riesco, M E; Argüelles, M; Nuño Mateo, J

    2005-01-01

    Intravascular lymphomatosis (IVL) is a rare malignancy characterized by a proliferation of atypical lymphoid cells occluding small blood vessels (venules, capillaries and small arteries). The symptoms are caused by embolisms due to massive proliferation. Nervous system and skin are the most common sites of involvement but all organs may be involved, although it is typified by the absence of malignant cells in lymphoid tissues. We describe three cases of IVL: first patient was a 57 years old man with rapidly progressive dementia and neurological involvements and second case of a 69 years old man hospitalised with predominant symptoms in the lung (cough, dyspnea and fever), and a woman presenting as fever of unknown origin (FUO) with systemic inflammatory response syndrome. In all cases that we reported have been diagnosed post-mortem because of rapid progression of a multisystem disease and the absence of pathognomonic clinical manifestations. Diagnosis can be made using biopsy of one of the involved organs. In conclusion, we propose that IVL should be included in the differential diagnosis of acute confusional state, dementia or other unexplained neurological manifestations, fever of unknown origin, vasculitis, occult neoplasia or infections with signs of a systemic disease and marked elevation of serum lactate dehydrogenase (LDH).

  10. Disseminated intravascular coagulation in solid tumors

    International Nuclear Information System (INIS)

    Terzieff, V.; Alonso, I.; Vázquez, A.

    2004-01-01

    It is estimated that 20-25% of cases of disseminated intravascular coagulation (DIC) relate to an underlying neoplasia primarily hematologic. It is estimated that about 5% of patients with solid tumors have CID clinic, although the incidence of subclinical alterations is much higher. The CID is not limited to the activation of the coagulation cascade, which leads to bleeding micro thrombosis and consumption of coagulation factors. Solid tumors are frequently associated adenocarcinomas producers mucin (especially gastric), usually in the context of a disseminated disease. The mucin may act as a promoter of the cascade, but probably it is a multi-event. High levels of TNF to produced by the tumor mass and chemotherapy-induced cell lysis have Also linked. Although the bleeding is usually oriented diagnosis, the most frequent cause of death is thrombosis. There are no specific tests for diagnosis. Elevated levels of D-dimer and products oriented fibrinogen degradation diagnosis. No reduction fibrinogen and almost always, one thrombocytopenia consumption. Treatment is complex and there is no consensus on many points. To recover the lost factors for consumption, it is recommended to use fresh frozen plasma and / or washed red blood cells. the heparin anticoagulation low dose is indicated since the disease causal can not be controlled quickly, but should not be initiated if there thrombocytopenia 50.000.El under profuse bleeding can require the use of tranexamic acid or EACA. Acute DIC, the case of our patient, is rare and very serious

  11. Assessing the Risk of Ovarian Malignancy in Asymptomatic Women With Abnormal CA 125 and Transvaginal Ultrasound in the Prostate, Lung, Colorectal, and Ovarian Screening Trial

    Science.gov (United States)

    Partridge, Edward E.; Greenlee, Robert T.; Riley, Thomas L.; Commins, John; Ragard, Lawrence; Xu, Jian-Lun; Buys, Saundra S.; Prorok, Philip C.; Fouad, Mona N.

    2012-01-01

    Objective To estimate the risk of ovarian malignancy among asymptomatic women with abnormal transvaginal ultrasound or CA 125 and to provide guidance to physicians managing these women. Methods A cohort of women from the Prostate, Lung, Colorectal, and Ovarian Cancer Screening Trial with abnormal ovarian results at the initial (T0) and subsequent (T1+) screens were analyzed to estimate which findings were associated with high risk of ovarian cancer. Risks of cancer of greater than 10% were designated as high and risks of 3% or less as low. Results For the T0 screen, two high-risk categories were identified: CA 125 of 70 or more with negative transvaginal ultrasound (positive predictive value [PPV] 15.9%, CI 14.7%–17.7%); and positive for both CA 125 and transvaginal ultrasound (PPV 25.0%, CI 23.3%–27.3%). For T1+ screens, three high-risk categories were identified: negative transvaginal ultrasound with change in CA 125 greater than 45 or more (PPV 29.0%, CI 28.3%–30.3%); increase in size of cyst 6 cm or greater with negative CA 125 (PPV 13.3%, CI 10.5%–18.0%); and positive for both tests (PPV 42.9%, CI 40.0%–46.0%). High-risk criteria for T0 provide a sensitivity of 60%, specificity 96.2%, PPV 19.7%, and a negative predictive value (NPV) of 99.3%. T1+ criteria yielded a sensitivity of 85.3%, specificity 95.6%, PPV 29.6% and NPV 99.7%. Conclusions High risk categories for predicting risk of cancer in women with abnormal CA 125, TVU or both at initial and subsequent screens have been identified. The large number of women in this study, the four year complete follow-up, and very small number of invasive cancers in the low risk categories provides guidance for clinical decisions regarding need for surgery in these women. PMID:23262924

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ... bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the prostate gland because ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement ... blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... performed to evaluate the: uterus cervix ovaries fallopian tubes bladder Pelvic ultrasound exams are also used to ... tissues that do not show up well on x-ray images. Ultrasound is the preferred imaging modality for ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... as detailed as with the transrectal probe. An MRI of the pelvis may be obtained as an ... Enlargement of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: pelvic pain abnormal ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... your knees toward your chest. To obtain high-quality images, an ultrasound transducer – a plastic cylinder about ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the procedure? In women, a pelvic ultrasound is most often performed to evaluate the: uterus cervix ovaries ... page How is the procedure performed? Transabdominal: For most ultrasound exams, you will be positioned lying face- ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... right in front of the rectum. top of page What are some common uses of the procedure? A ... ultrasound to clean out the bowel. top of page What does the equipment look like? Ultrasound scanners consist ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... depth investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... with abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. In ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... kidneys. top of page What are some common uses of the procedure? In women, a pelvic ultrasound ... patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Ultrasound exams in which the transducer ... in the sperm or urine following the procedure. After an ultrasound examination, you should be able to ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... obtain high-quality images, an ultrasound transducer – a plastic cylinder about the size of a finger – is ... end of their bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's (Pediatric) Ultrasound - ... facilities database . This website does not provide cost information. The costs for specific medical imaging tests, treatments ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... records tiny changes in the sound's pitch and direction. These signature waves are instantly measured and displayed ... ultrasound, a special application of ultrasound, measures the direction and speed of blood cells as they move ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also help identify: ... fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ... pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... abnormal growth within the prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of ... show up well on x-ray images. Ultrasound causes no health problems and may be repeated as ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... help to distract the child and make the time pass quickly. The ultrasound exam room may have ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? In women, a pelvic ultrasound is most ... child's favorite channel. top of page What does the equipment look like? Ultrasound scanners consist of a ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... extract a sample of cells from organs for laboratory testing. Doppler ultrasound images can help the physician ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Transvaginal ultrasound is performed very much like a gynecologic exam and involves the insertion of the transducer ... with your feet in stirrups similar to a gynecologic exam. Transrectal: For a transrectal ultrasound, a protective ...

  5. Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

    Science.gov (United States)

    Waseda, Katsuhisa; Ako, Junya; Yamasaki, Masao; Koizumi, Tomomi; Sakurai, Ryota; Hongo, Yoichiro; Koo, Bon-Kwon; Ormiston, John; Worthley, Stephen G; Whitbourn, Robert J; Walters, Darren L; Meredith, Ian T; Fitzgerald, Peter J; Honda, Yasuhiro

    2011-06-01

    Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Data were obtained from the first-in man trial or first randomized trials of each stent, The Clinical RESpOnse EvaLUation of the MedTronic Endeavor CR ABT-578 Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions (RESOLUTE), Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions (ENDEAVOR II), and ZoMaxx I trials. Follow-up intravascular ultrasound analyses (8 to 9 months of follow-up) were possible in 353 patients (Resolute: 88, Endeavor: 98, ZoMaxx: 82, Driver: 85). Volume index (volume/stent length) was obtained for vessel, stent, lumen, peristent plaque, and neointima. Cross-sectional narrowing was defined as neointimal area divided by stent area (%). Neointima-free frame ratio was calculated as the number of frames without intravascular ultrasound-detectable neointima divided by the total number of frames within the stent. At baseline, vessel, lumen, and peristent plaque volume index were not significantly different among the 4 stent groups. At follow-up, percent neointimal obstruction was significantly lower in Resolute compared with Endeavor, ZoMaxx, and Driver (Resolute: 3.7±4.0, Endeavor: 17.5±10.1, ZoMaxx: 14.6±8.1, Driver: 29.4±17.2%; Ppolymer used in Resolute independently correlated with neointimal suppression among 3 zotarolimus-eluting stents. The different polymer formulations significantly affect the relative amount of neointima for zotarolimus-eluting stents. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00248079.

  6. Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents

    Czech Academy of Sciences Publication Activity Database

    Harabis, V.; Kolář, R.; Mézl, M.; Jiřík, Radovan

    2013-01-01

    Roč. 34, č. 2 (2013), s. 151-162 ISSN 0967-3334 R&D Projects: GA ČR GAP102/12/2380 Institutional support: RVO:68081731 Keywords : perfusion model * ultrasound * contrast agent * intravascular perfusion * tissue phantom Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 1.617, year: 2013

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Pelvic Ultrasound Imaging? Ultrasound waves are ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning may be able to give a ...

  10. Randomized pilot trial of gene expression profiling versus heart biopsy in the first year after heart transplant: early invasive monitoring attenuation through gene expression trial.

    Science.gov (United States)

    Kobashigawa, Jon; Patel, Jignesh; Azarbal, Babak; Kittleson, Michelle; Chang, David; Czer, Lawrence; Daun, Tiffany; Luu, Minh; Trento, Alfredo; Cheng, Richard; Esmailian, Fardad

    2015-05-01

    The endomyocardial biopsy (EMB) is considered the gold standard in rejection surveillance post cardiac transplant, but is invasive, with risk of complications. A previous trial suggested that the gene expression profiling (GEP) blood test was noninferior to EMB between 6 and 60 months post transplant. As most rejections occur in the first 6 months, we conducted a single-center randomized trial of GEP versus EMB starting at 55 days post transplant (when GEP is valid). Sixty heart transplant patients meeting inclusion criteria were randomized beginning at 55 days post transplant to either GEP or EMB arms. A positive GEP ≥30 between 2 and 6 months, or ≥34 after 6 months, prompted a follow-up biopsy. The primary end point included a composite of death/retransplant, rejection with hemodynamic compromise or graft dysfunction at 18 months post transplant. A coprimary end point included change in first-year maximal intimal thickness by intravascular ultrasound, a recognized surrogate for long-term outcome. Corticosteroid weaning was assessed in both the groups. The composite end point was similar between the GEP and EMB groups (10% versus 17%; log-rank P=0.44). The coprimary end point of first-year intravascular ultrasound change demonstrated no difference in mean maximal intimal thickness (0.35±0.36 versus 0.36±0.26 mm; P=0.944). Steroid weaning was successful in both the groups (91% versus 95%). In this pilot study, GEP starting at 55 days post transplant seems comparable with EMB for rejection surveillance in selected heart transplant patients and does not result in increased adverse outcomes. GEP also seems useful to guide corticosteroid weaning. Larger randomized trials are required to confirm these findings. URL: http://www.clinicaltrials.gov. Unique identifier: NCT014182482377. © 2015 American Heart Association, Inc.

  11. Fulminant intravascular lymphomatosis mimicking acute haemorrhagic leukoencephalopathy.

    Science.gov (United States)

    Marino, D; Sicurelli, F; Cerase, A; Tripodi, S; Cintorino, M; Lazzi, S; Federico, A

    2012-09-15

    Intravascular lymphomatosis (IVL) is a rare non-Hodgkin's lymphoma, usually of B cell lineage, characterized by massive angiotropic growth. The clinical presentation of IVL may include changes in mental status, non-localizing neurological deficits, seizures, fever of unknown origin and skin changes. Because of its rarity and the absence of specific diagnostic procedures except for cerebral biopsy, diagnosis is often postmortem. Brain MRI usually shows non-specific abnormalities. The purpose of this case report is to increase the knowledge of clinical and neuroimaging features of IVL by describing the findings observed in a 71-year-old patient. A 71-year-old male was admitted for right hemiparesis, acute cognitive impairment and febricula. A bone marrow biopsy resulted normal. He then developed a rapid progressive impairment of his mental status and left hemisoma motor seizures. Brain CT and MRI were interpreted as consistent with acute haemorrhagic leukoencephalopathy (AHLE), including multiple areas of restricted diffusion without gadolinium enhancement and a small focal area of gadolinium enhancement in the left temporal lobe white matter. The patient died within a few days and the autopsy led to the diagnosis of IVL. IVL may present with a variety of clinical signs and symptoms, including stroke and hemiparesis. IVL may mimic AHLE at brain MRI. However, the evidence of multiple areas of restricted diffusion without gadolinium enhancement and of a small area of gadolinium enhancement could have led to the correct diagnosis. IVL should be added to the differential diagnosis of AHLE at brain MRI. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Ultrasound-Guided Miniscalpel-Needle Release versus Dry Needling for Chronic Neck Pain: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Yongjun Zheng

    2014-01-01

    Full Text Available Objective. To compare ultrasound-guided miniscalpel-needle (UG-MSN release versus ultrasound-guided dry needling (UG-DN for chronic neck pain. Methods. A total of 169 patients with chronic neck pain were randomized to receive either UG-MSN release or UG-DN. Before treatment and at 3 and 6 months posttreatment, pain was measured using a 10-point visual analogue scale (VAS. Neck function was examined using the neck disability index. Health-related quality of life was examined using the physical component score (PCS and mental component score (MCS of the SF-36 health status scale. Results. Patients in the UG-MSN release had greater improvement on the VAS (by 2 points at 3 months and 0.9 points at 6 months versus in the UG-DN arm; (both P<0.0001. Patients receiving UG-MSN release also showed significantly lower scores on the adjusted neck disability index, as well as significantly lower PCS. No severe complications were observed. Conclusion. UG-MSN release was superior to UG-DN in reducing pain intensity and neck disability in patients with chronic neck pain and was not associated with severe complications. The procedural aspects in the two arms were identical; however, we did not verify the blinding success. As such, the results need to be interpreted with caution.

  13. Analgesic Efficacy of Intrarectal Instillation of Lidocaine Gel prior to Transrectal Ultrasound Guided Prostate Biopsy: A Prospective Randomized Trial

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Tae Jin; Kim, Seung Hyup; Cho, Jeong Yeon [Seoul National University Hospital, Seoul (Korea, Republic of); Lee, Hak Jong; Lee, Sang Eun; Byun, Seok Soo [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Seong, Chang Kyu [Seoul National University Borame Hospital, Seoul (Korea, Republic of)

    2006-06-15

    To assess the analgesic efficacy of intrarectal lidocaine gel instillation prior to periprostatic nerve block during transrectal, ultrasound-guided prostate biopsies. Between March 2004 and October 2004, 203 consecutive patients for prostate biopsies were randomized into two groups. In 90 patients of group A, 10ml of 2% lidocaine gel was instilled intrarectally 10 minutes prior to periprostatic neurovascular bundle block, while 113 patients of group B received only periprostatic neurovascular bundle block without lidocaine gel instillation. Pain was assessed with the visual analogue pain scale, during periprostatic neurovascular bundle block (VAS 1), during the biopsy procedures (VAS 2) and 20 minutes after the procedure (VAS 3). The difference in VAS scores between patients in the two groups was evaluated with the unpaired t-test, with p < 0.05 considered significant. Patients in group A experienced statistically less pain during transrectal ultrasound guided prostate biopsy (VAS 2, 2.994 versus 3.903, p < 0.01). However, no significant difference in VAS values could be demonstrated during periprostatic neurovascular bundle block (VAS 1, 4.761 versus 5.133, p > 0.05) or at after 20 minutes after the procedure (VAS 3, 0.9778 versus 1.257, p > 0.05). Intrarectal instillation of lidocaine gel leads to significant additional analgesic efficacy during the biopsy procedure. It is a simple, safe and rapid technique that should be considered in all patients undergoing TRUS guided prostate biopsy

  14. The Clinical Atlas of Intravascular Optical Coherence Tomography for iPad

    DEFF Research Database (Denmark)

    Radu, Maria D

    2012-01-01

    The first comprehensive educational tool devoted exclusively to intravascular OCT is now available from PCR publishing.......The first comprehensive educational tool devoted exclusively to intravascular OCT is now available from PCR publishing....

  15. Low molecular weight heparin attenuates multiple organ failure in a murine model of disseminated intravascular coagulation

    NARCIS (Netherlands)

    Slofstra, Sjoukje H.; van 't Veer, Cornelis; Buurman, Wim A.; Reitsma, Pieter H.; ten Cate, Hugo; Spek, C. Arnold

    2005-01-01

    OBJECTIVE: Bacterial sepsis causes widespread vascular inflammation that frequently leads to disseminated intravascular coagulation (DIC). Although intravascular coagulation contributes to organ failure, it is often debated whether anticoagulant therapy produces any beneficial effects in patients

  16. Emergency treatment by intravascular embolization in traumatic carotid cavernous fistula

    International Nuclear Information System (INIS)

    Tang Jun; Sun Zengtao; Liu Zuoqin; Liu Yanjun; Li Fengxin

    2006-01-01

    Objective: To discuss the method of intervenfional intravascular treatment in traumatic carotid cavernous fistula (TCCF) and the significance of clinical application in emergency. Methods: In 297 eases of TCCF, 36 cases were treated by interventional intravascular embolization by detachable balloon, embolization orificium or occlusion in one side of carotid artery. In the 36 cases, serious epistaxis occurred in 22 eases, cortical vein inflow in 9 cases, intracranial hemorrhage in 3 cases, aggravation of eyesight in 3 cases, and limb dysfunction in 2 cases. Results: Fistula was successfully embolized and internal carotid artery remained patent in 19 cases. Complete embolization of orificium or internal carotid artery was achieved in 17 eases. The serious epistaxias in 22 cases and intracranial hemorrhage in 3 cases stopped. Eyesight recovered in 2 eases and improved in 1 case. Limb dysfunction improved evidently in 2 cases. Conclusion: Intravascular embolization treatment is the first therapeutic choice for TCCF, especially in emergency. It is necessary, safe and effective. (authors)

  17. Social media to supplement point-of-care ultrasound courses: the "sandwich e-learning" approach. A randomized trial.

    Science.gov (United States)

    Hempel, Dorothea; Haunhorst, Stephanie; Sinnathurai, Sivajini; Seibel, Armin; Recker, Florian; Heringer, Frank; Michels, Guido; Breitkreutz, Raoul

    2016-12-01

    Point-of-care ultrasound (POC-US) is gaining importance in almost all specialties. E-learning has been used to teach theoretical knowledge and pattern recognition. As social media are universally available, they can be utilized for educational purposes. We wanted to evaluate the utility of the sandwich e-learning approach defined as a pre-course e-learning and a post-course learning activity using Facebook after a one-day point-of-care ultrasound (POC-US) course and its effect on the retention of knowledge. A total of 62 medial students were recruited for this study and randomly assigned to one of four groups. All groups received an identical hands-on training and performed several tests during the study period. The hands-on training was performed in groups of five students per instructor with the students scanning each other. Group 1 had access to pre-course e-learning, but not to post-course e-learning. Instead of a pre-course e-learning, group 2 listened to presentations at the day of the course (classroom teaching) and had access to the post-course learning activity using Facebook. Group 3 had access to both pre- and post-course e-learning (sandwich e-learning) activities, while group 4 listened classroom presentations only (classroom teaching only). Therefore only groups 2 and 3 had access to post-course learning via Facebook by joining a secured group. Posts containing ultrasound pictures and videos were published to this group. The students were asked to "like" the posts to monitor attendance. Knowledge retention was assessed 6 weeks after the course. After 6 weeks, group 3 achieved comparable results when compared to group 2 (82.2 % + -8.2 vs. 84.3 + -8.02) (p = 0.3). Students who participated in the post-course activity were more satisfied with the overall course than students without post-course learning (5.5 vs. 5.3 on a range from 1 to 6). In this study, the sandwich e-learning approach led to equal rates of knowledge retention compared to

  18. Improved healing response in delayed unions of the tibia with low-intensity pulsed ultrasound: results of a randomized sham-controlled trial

    Directory of Open Access Journals (Sweden)

    Aigner Julia

    2010-10-01

    Full Text Available Abstract Background We compared the healing response of tibial delayed unions between subjects treated with low-intensity pulsed ultrasound (LIPUS (n = 51 and subjects treated with a sham device (n = 50. Fracture age was ≥ 4 months in all cases. Study personnel and participants were blinded to random treatment assignment throughout the study. Methods This multi-center randomized sham-controlled trial was undertaken at six hospitals in Germany. Adult patients who had sustained a tibial shaft fracture that subsequently showed inadequate progress toward healing (i.e., delayed union were enrolled and randomized to receive either LIPUS (Exogen 2000/2000+, Smith & Nephew GmbH, Schenefeld, Germany or an identical nonoperative sham device. The daily treatment duration was 20 minutes, for a period of 16 weeks. Subjects randomly assigned to active treatment had the ultrasound pressure wave signal set at the following parameters: 1.5 MHz frequency, 1 kHz repetition rate, 200 μs pulse duration, 30 mW/cm2 spatial intensity. Progress toward healing was estimated from changes in bone mineral density (BMD and gap area as determined from computed tomography scans. Intention-to-treat analysis was conducted using a multiple imputation methodology. Results Based on log-transformed data, mean improvement in BMD was 1.34 (90% confidence interval (CI 1.14 to 1.57 times greater for LIPUS-treated subjects compared to sham (p = 0.002. A mean reduction in bone gap area also favored LIPUS treatment (p = 0.014. Conclusions These findings demonstrate significantly greater progress toward bone healing after LIPUS treatment compared to no LIPUS treatment in subjects with established delayed unions of the tibia.

  19. Extremely refractory Kawasaki disease with disseminated intravascular coagulation.

    Science.gov (United States)

    Koh, Young Kwon; Lee, Jae Hee; Park, Yeong Bong

    2017-07-01

    Disseminated intravascular coagulation is a rare complication of Kawasaki disease and appears in Kawasaki disease patients. We report a case of refractory Kawasaki disease complicated with disseminated intravascular coagulation and giant coronary aneurysm. A 5-month-old boy presented with Kawasaki disease with coagulopathy. Although the coagulopathy improved after fresh-frozen plasma and antithrombin-III administration, the fever persisted despite two rounds of intravenous immunoglobulin, along with intravenous methylprednisolone pulse therapy and infliximab administration. Despite all efforts to treatment, the patient had giant coronary aneurysms and died suddenly.

  20. Minimum Effective Concentration of Bupivacaine in Ultrasound-Guided Femoral Nerve Block after Arthroscopic Knee Meniscectomy: A Randomized, Double-Blind, Controlled Trial.

    Science.gov (United States)

    Moura, Ed Carlos Rey; de Oliveira Honda, Claudio A; Bringel, Roberto Cesar Teixeira; Leal, Plinio da Cunha; Filho, Gasper de Jesus Lopes; Sakata, Rioko Kinmiko

    2016-01-01

    Adequate analgesia is important for early hospital discharge after meniscectomy. A femoral nerve block may reduce the need for systemic analgesics, with fewer side effects; however, motor block can occur. Ultrasound-guided femoral nerve block may reduce the required local anesthetic concentration, preventing motor block. The primary objective of this study was to determine the lowest effective analgesic concentration of bupivacaine in 50% (EC50) and in 90% (EC90) of patients for a successful ultrasound-guided femoral nerve block in arthroscopic knee meniscectomy. This was a prospective, randomized, double-blind, controlled trial. This study was conducted at Hospital São Domingos. A total of 52 patients undergoing arthroscopic knee meniscectomy were submitted to ultrasound-guided femoral nerve block using 22 mL bupivacaine. The bupivacaine concentration given to a study patient was determined by the response of the previous patient (a biased-coin design up-down sequential method). If the previous patient had a negative response, the bupivacaine concentration was increased by 0.05% for the next case. If the previous patient had a positive response, the next patient was randomized to receive the same bupivacaine concentration (with a probability of 0.89) or to have a decrease by 0.05% (with a probability of 0.11). A successful block was defined by a numerical pain intensity scale score block was considered failed. General anesthesia was induced with 30 µg/kg alfentanil and 2 mg/kg propofol, followed by propofol maintanance, plus remifentanil if needed. Postoperative analgesia supplementation was performed with dipyrone; ketoprofen and tramadol were given if needed. The following parameters were evaluated: numerical pain intensity score, duration of analgesia, supplementary analgesic dose in 24 hours, and need for intraoperative remifentanil. The EC50 was 0.160 (95% CI: 0.150 - 0.189), and EC90 was 0.271 (95% CI: 0.196 - 0.300). There was no difference in numerical

  1. 21 CFR 880.5970 - Percutaneous, implanted, long-term intravascular catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Percutaneous, implanted, long-term intravascular... and Personal Use Therapeutic Devices § 880.5970 Percutaneous, implanted, long-term intravascular catheter. (a) Identification. A percutaneous, implanted, long-term intravascular catheter is a device that...

  2. 21 CFR 880.5965 - Subcutaneous, implanted, intravascular infusion port and catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Subcutaneous, implanted, intravascular infusion... Hospital and Personal Use Therapeutic Devices § 880.5965 Subcutaneous, implanted, intravascular infusion port and catheter. (a) Identification. A subcutaneous, implanted, intravascular infusion port and...

  3. Midpregnancy Doppler ultrasound of the uterine artery in metformin- versus placebo-treated PCOS women: a randomized trial.

    Science.gov (United States)

    Stridsklev, Solhild; Carlsen, Sven M; Salvesen, Øyvind; Clemens, Ilka; Vanky, Eszter

    2014-03-01

    Metformin is used to reduce pregnancy complications in women with polycystic ovary syndrome (PCOS), although it is not approved for this indication and solid evidence is lacking. Midpregnancy Doppler ultrasound is one of the best methods for prediction of adverse pregnancy outcome. The objectives of the study were to investigate the following: 1) whether metformin treatment influenced the midpregnancy pulsatility index (PI) of the uterine artery; 2) whether metabolic or endocrine factors affect the PI of the uterine artery of PCOS women; and 3) whether PI predicted adverse pregnancy outcome in PCOS woman. This is a substudy of a randomized, placebo-controlled, double-blind, multicenter study conducted at 11 secondary care centers. We randomly assigned 273 pregnancies to receive metformin or placebo, from the first trimester of pregnancy to delivery. In the present substudy, 231 pregnancies are included, ie, those who completed the ultrasound examinations. Midpregnancy PI in the uterine artery related to metformin use, androgen levels, an oral glucose tolerance test, and insulin levels was measured. We found no difference in the PI between the metformin and placebo groups. In multivariate analyses, fasting serum glucose of the first and second trimester correlated positively to the midpregnancy PI. Only in univariate analyses a weak correlation between androstenedione and PI was seen. Metformin treatment did not affect uterine artery blood flow, measured by PI. High fasting blood glucose correlated inversely to uterine artery blood flow. The midpregnancy PI correlated positively to preeclampsia, hypertension, and gestational diabetes mellitus in PCOS pregnancies. Androgen levels correlated only to PI in univariate analyses.

  4. Remote just-in-time telementored trauma ultrasound: a double-factorial randomized controlled trial examining fluid detection and remote knobology control through an ultrasound graphic user interface display.

    Science.gov (United States)

    Kirkpatrick, Andrew W; McKee, Ian; McKee, Jessica L; Ma, Irene; McBeth, Paul B; Roberts, Derek J; Wurster, Charles L; Parfitt, Robbie; Ball, Chad G; Oberg, Scott; Sevcik, William; Hamilton, Douglas R

    2016-05-01

    Remote-telementored ultrasound involves novice examiners being remotely guided by experts using informatic-technologies. However, requiring a novice to perform ultrasound is a cognitively demanding task exacerbated by unfamiliarity with ultrasound-machine controls. We incorporated a randomized evaluation of using remote control of the ultrasound functionality (knobology) within a study in which the images generated by distant naive examiners were viewed on an ultrasound graphic user interface (GUI) display viewed on laptop computers by mentors in different cities. Fire-fighters in Edmonton (101) were remotely mentored from Calgary (n = 65), Nanaimo (n = 19), and Memphis (n = 17) to examine an ultrasound phantom randomized to contain free fluid or not. Remote mentors (2 surgeons, 1 internist, and 1 ED physician) were randomly assigned to use GUI knobology control during mentoring (GUIK+/GUIK-). Remote-telementored ultrasound was feasible in all cases. Overall accuracy for fluid detection was 97% (confidence interval = 91 to 99%) with 3 false negatives (FNs). Positive/negative likelihood ratios were infinity/0.0625. One FN occurred with the GUIK+ and 2 without (GUIK-). There were no statistical test performance differences in either group (GUIK+ and GUIK-). Ultrasound-naive 1st responders can be remotely mentored with high accuracy, although providing basic remote control of the knobology did not affect outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. The effects of serial intravascular transfusions in ascitic/hydropic RhD-alloimmunized fetuses.

    Science.gov (United States)

    Craparo, F J; Bonati, F; Gementi, P; Nicolini, U

    2005-02-01

    To evaluate the effects of serial intravascular transfusions on RhD-alloimmunized fetuses with ascites/hydrops at the time of the first transfusion by measuring multiple hematological/biochemical blood variables. Thirty-one singleton pregnancies were referred for management of RhD alloimmunization. Seven fetuses had hydrops on presentation and were transfused immediately. The remainder underwent weekly ultrasound examinations, and fetal blood sampling and transfusion were performed on development of ascites. In the 104 samples collected overall from the 31 fetuses, glucose, uric acid, urea, creatinine, total protein, total and direct bilirubin, aspartate aminotransferase (AST), alanine aminotransferase (ALT), gamma-glutamyltransferase, alkaline phosphatase, lactic dehydrogenase, amylase, pseudocholinesterase (PCHE), creatine kinase, triglycerides and cholesterol were measured and compared with a reference range for non-anemic fetuses. The median gestational age at first transfusion was 26 (range, 18-34) weeks. There were three fetal losses after the first transfusion, two of which were due to procedure-related complications; one further loss occurred. At the first transfusion fetal hematocrit, pO2, total protein, PCHE, creatinine and urea concentrations were significantly decreased compared to reference data, while total and direct bilirubin, AST, ALT, amylase, triglyceride and uric acid concentrations were increased. In all surviving fetuses ascites/hydrops had disappeared by the second transfusion. Fetal pO2, total protein, AST, ALT and PCHE concentrations had normalized by the third transfusion. Correction of fetal anemia did not affect the other variables. RhD-alloimmunized fetuses with ascites/hydrops at the time of the first transfusion had a survival rate of 87%. Alterations of several biochemical fetal blood indices are present at the first sampling/transfusion, but most variables normalize with intravascular transfusions. Copyright 2005 ISUOG.

  6. Safety and Efficacy of Focused Ultrasound Thalamotomy for Patients With Medication-Refractory, Tremor-Dominant Parkinson Disease: A Randomized Clinical Trial.

    Science.gov (United States)

    Bond, Aaron E; Shah, Binit B; Huss, Diane S; Dallapiazza, Robert F; Warren, Amy; Harrison, Madaline B; Sperling, Scott A; Wang, Xin-Qun; Gwinn, Ryder; Witt, Jennie; Ro, Susie; Elias, W Jeffrey

    2017-12-01

    Clinical trials have confirmed the efficacy of focused ultrasound (FUS) thalamotomy in essential tremor, but its effectiveness and safety for managing tremor-dominant Parkinson disease (TDPD) is unknown. To assess safety and efficacy at 12-month follow-up, accounting for placebo response, of unilateral FUS thalamotomy for patients with TDPD. Of the 326 patients identified from an in-house database, 53 patients consented to be screened. Twenty-six were ineligible, and 27 were randomized (2:1) to FUS thalamotomy or a sham procedure at 2 centers from October18, 2012, to January 8, 2015. The most common reasons for disqualification were withdrawal (8 persons [31%]), and not being medication refractory (8 persons [31%]). Data were analyzed using intention-to-treat analysis, and assessments were double-blinded through the primary outcome. Twenty patients were randomized to unilateral FUS thalamotomy, and 7 to sham procedure. The sham group was offered open-label treatment after unblinding. The predefined primary outcomes were safety and difference in improvement between groups at 3 months in the on-medication treated hand tremor subscore from the Clinical Rating Scale for Tremor (CRST). Secondary outcomes included descriptive results of Unified Parkinson's Disease Rating Scale (UPDRS) scores and quality of life measures. Of the 27 patients, 26 (96%) were male and the median age was 67.8 years (interquartile range [IQR], 62.1-73.8 years). On-medication median tremor scores improved 62% (IQR, 22%-79%) from a baseline of 17 points (IQR, 10.5-27.5) following FUS thalamotomy and 22% (IQR, -11% to 29%) from a baseline of 23 points (IQR, 14.0-27.0) after sham procedures; the between-group difference was significant (Wilcoxon P = .04). On-medication median UPDRS motor scores improved 8 points (IQR, 0.5-11.0) from a baseline of 23 points (IQR, 15.5-34.0) following FUS thalamotomy and 1 point (IQR, -5.0 to 9.0) from a baseline of 25 points (IQR, 15.0-33.0) after sham

  7. Combined short- and long-axis ultrasound-guided central venous catheterization is superior to conventional techniques: A cross-over randomized controlled manikin trial.

    Directory of Open Access Journals (Sweden)

    Jun Takeshita

    Full Text Available Visualizing the needle tip using the short-axis (SA ultrasound-guided central venous catheterization approach can be challenging. It has been suggested to start the process with the SA approach and then switch to the long-axis (LA; however, to our knowledge, this combination has not been evaluated. We compared the combined short- and long-axis (SLA approach with the SA approach in a manikin study.We performed a prospective randomized controlled cross-over study in an urban emergency department and intensive care unit. Resident physicians in post-graduate years 1-2 performed a simulated ultrasound-guided internal jugular vein puncture using the SA and SLA approaches on manikins. Twenty resident physicians were randomly assigned to two equal groups: (1 one group performed punctures using the SA approach followed by SLA; and (2 the other performed the same procedures in the opposite order. We compared the success rate and procedure duration for the two approaches. Procedural success was defined as insertion of the guide-wire into the vein while visualizing the needle tip at the time of anterior wall puncture, without penetrating the posterior wall.Six resident physicians (30% performed both approaches successfully, while 12 (60% performed the SLA approach, but not the SA, successfully. Those who performed the SA approach successfully also succeeded with the SLA approach. Two resident physicians (10% failed to perform both approaches. The SLA approach had a significantly higher success rate than the SA approach (P < 0.001. The median (interquartile range procedure duration was 59.5 [46.0-88.5] seconds and 45.0 [37.5-84.0] seconds for the SLA and SA approaches, respectively. The difference of the duration between the two procedures was 15.5 [0-28.5] seconds. There was no significant difference in duration between the two approaches (P = 0.12.Using the SLA approach significantly improved the success rate of internal jugular vein puncture performed by

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  9. 21 CFR 880.5440 - Intravascular administration set.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intravascular administration set. 880.5440 Section 880.5440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use...

  10. Intravascular catheter related infections in children admitted on the ...

    African Journals Online (AJOL)

    peripheral venous intravascular catheters uncoated with no antibiotic or antiseptic, was done. Social demographic characteristics, anthropometry, clinical examination including the catheter site were determined at enrollment. The children had their blood, catheter tip and hub samples taken off for culture and sensitivity as ...

  11. Disseminated intravascular coagulation in malaria: A case report ...

    African Journals Online (AJOL)

    Disseminated intravascular coagulation (DIC) is seen in <5% of patients with severe Plasmodium falciparum malaria and is more common in cerebral malaria. Here, we report the diagnosis and management of a case of severe P. falciparum malaria with DIC. Keywords: Cerebral malaria, cytokine storm, DIC, heparin ...

  12. Disseminated intravascular coagulation in meningococcal sepsis. Case 7

    NARCIS (Netherlands)

    Zeerleder, S.; Zürcher Zenklusen, R.; Hack, C. E.; Wuillemin, W. A.

    2003-01-01

    We report on a man (age: 49 years), who died from severe meningococcal sepsis with disseminated intravascular coagulation (DIC), multiple organ dysfunction syndrome and extended skin necrosis. We discuss in detail the pathophysiology of the activation of coagulation and fibrinolysis during sepsis.

  13. Intravascular catheter sepsis | Mer | South African Medical Journal

    African Journals Online (AJOL)

    Intravascular devices are an integral component of modern-day medical practice. They are used to administer intravenous fluids, medications, blood products and parenteral nutrition. In addition, they serve as a valuable monitor of the haemodynamic status of critically ill patients.

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce ... the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and ...

  16. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery

    Directory of Open Access Journals (Sweden)

    Vera ePaefgen

    2015-09-01

    Full Text Available Ultrasound is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents. There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular contrast agents enable functional analyses, e.g. to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles’ shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by ultrasound pulses to locally release the entrapped agent. Recent studies show that ultrasound contrast agents are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of ultrasound contrast agents and introduces the current clinical applications of contrast-enhanced ultrasound. Additionally, an overview of the recent developments in ultrasound probe design for functional and molecular diagnosis as well as for drug delivery is given.

  17. Hepatic applications of endoscopic ultrasound

    DEFF Research Database (Denmark)

    Srinivasan, Indu; Tang, Shou-Jiang; Vilmann, Andreas S

    2015-01-01

    The diagnosis and staging of various gastrointestinal malignancies have been made possible with the use of endoscopic ultrasound, which is a relatively safe procedure. The field of endoscopic ultrasound is fast expanding due to advancements in therapeutic endoscopic ultrasound. Though various...... studies have established its role in gastrointestinal malignancies and pancreatic conditions, its potential in the field of hepatic lesions still remains vastly untapped. In this paper the authors attempt to review important and landmark trials, case series and case studies involving hepatic applications...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Prostate Ultrasound Imaging? Men who have ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to ...

  3. Ultrasound -- Vascular

    Science.gov (United States)

    ... waves from passing into your body. The sonographer (ultrasound technologist) or radiologist then places the transducer on the ... is specialized and is best performed by a technologist and physician with experience in vascular ultrasound imaging. top of page Additional Information and Resources ...

  4. Cardiopulmonary ultrasound for critically ill adults improves diagnostic accuracy in a resource-limited setting: the AFRICA trial.

    Science.gov (United States)

    Becker, Torben K; Tafoya, Chelsea A; Osei-Ampofo, Maxwell; Tafoya, Matthew J; Kessler, Ross A; Theyyunni, Nikhil; Yakubu, Hussein A; Opuni, Daniel; Clauw, Daniel J; Cranford, James A; Oppong, Chris K; Oteng, Rockefeller A

    2017-12-01

    To assess the effects of a cardiopulmonary ultrasound (CPUS) examination on diagnostic accuracy for critically ill patients in a resource-limited setting. Approximately half of the emergency medicine resident physicians at the Komfo Anokye Teaching Hospital (KATH) in Kumasi, Ghana, were trained in a CPUS protocol. Adult patients triaged to the resuscitation area of the emergency department (ED) were enrolled if they exhibited signs or symptoms of shock or respiratory distress. Patients were assigned to the intervention group if their treating physician had completed the CPUS training. The physician's initial diagnostic impression was recorded immediately after the history and physical examination in the control group, and after an added CPUS examination in the intervention group. This was compared to a standardised final diagnosis derived from post hoc chart review of the patient's care at 24 h by two blinded, independent reviewers using a clearly defined and systematic process. Secondary outcomes were 24-h mortality and use of IV fluids, diuretics, vasopressors and bronchodilators. Of 890 patients presenting during the study period, 502 were assessed for eligibility, and 180 patients were enrolled. Diagnostic accuracy was higher for patients who received the CPUS examination (71.9% vs. 57.1%, Δ 14.8% [CI 0.5%, 28.4%]). This effect was particularly pronounced for patients with a 'cardiac' diagnosis, such as cardiogenic shock, congestive heart failure or acute valvular disease (94.7% vs. 40.0%, Δ 54.7% [CI 8.9%, 86.4%]). Secondary outcomes were not different between groups. In an urban ED in Ghana, a CPUS examination improved the accuracy of the treating physician's initial diagnostic impression. There were no differences in 24-h mortality and a number of patient care interventions. © 2017 John Wiley & Sons Ltd.

  5. Ultrasound imaging

    International Nuclear Information System (INIS)

    Grant, E.G.; Doherty, F.J.

    1986-01-01

    Diagnostic ultrasound was used as early as 1950 in attempts to detect malignant tumors within the human breast and brain. In the years following, however, little attention was paid to this method of imaging by the radiologic community. Extensive work with this technique was not begun until the 1960s, when bistable ultrasound enabled sonographers to display organ outlines for the first time. Prior to the development of bistable ultrasound, sonographic images were limited to A-mode displays, which were merely a series of amplitude spikes on a graph. Over the past 20 or so years, major advances in ultrasound technology have gradually taken us from the simple graphic A-mode display, through bistable organ outlines, to gray-scale images with excellent parenchymal detail, and finally to real-time ultrasound

  6. Therapeutic ultrasound for pressure ulcers.

    Science.gov (United States)

    Baba-Akbari Sari, A; Flemming, K; Cullum, N A; Wollina, U

    2006-07-19

    Pressure ulcers have been recorded as occurring in 5 to 32% of patients admitted to a UK District General Hospital (the precise rate depends on case-mix) and 4 to 7% in the community. They represent a major burden of sickness and reduced quality of life for patients and their carers, and are costly to health service providers. Pressure ulcers are treated by using wound dressings, relieving pressure on the wound, by treating concurrent conditions which may delay healing, and by the use of physical therapies such as electrical stimulation, laser therapy and ultrasound. To assess the effect of therapeutic ultrasound on the healing of pressure ulcers. We searched the Cochrane Wounds Group Specialised Register and the Cochrane Central Register of Controlled Trials in May 2006. In addition we hand searched journals, conference proceedings, bibliographies and reference lists of articles. Randomised controlled trials (RCTs) comparing therapeutic ultrasound with sham ultrasound or standard treatment. Two authors independently checked the result of the search to identify relevant RCTs. Details of eligible studies were extracted and summarised using a data extraction sheet. Attempts were made to obtain missing information by contacting authors. Data extraction was checked by a second author. Meta-analysis was used to combine the results of trials where the interventions and outcome measures were sufficiently similar. Three trials involving 146 people were included. Two RCTs compared ultrasound therapy with sham ultrasound and the third compared a combination of ultrasound and ultraviolet light with laser and with standard treatment. Neither of the two RCTs comparing ultrasound with sham found a significant difference in healing rates. The trials were pooled, in the absence of significant heterogeneity. There was no evidence of benefit associated with the use of ultrasound in the treatment of pressure ulcers. In the three-arm comparison there was no statistically significant

  7. Cranial Ultrasound/Head Ultrasound

    Science.gov (United States)

    ... waves from passing into the body. The sonographer (ultrasound technologist) or radiologist then gently presses the transducer against ... performed on an infant, a nurse or radiologic technologist may assist with keeping the ... procedure? Ultrasound examinations are painless and easily tolerated by most ...

  8. The Prevalence of Japanese Outpatients with Hypertension Who Meet the Definition of Treatment Resistant Hypertension and Are Eligible for Enrolment in Clinical Trials of Endovascular Ultrasound Renal Denervation.

    Science.gov (United States)

    Okamura, Keisuke; Shirai, Kazuyuki; Okuda, Tetsu; Urata, Hidenori

    2018-01-01

    Objective A clinical trial (REQUIRE) was started to investigate the use of an ultrasound renal denervation system in the treatment of resistant hypertension (RHT). We analyzed the prevalence of patients who were eligible for inclusion in this cross-sectional study at the time of screening. Methods Nine-hundred ninety-nine consecutive hypertension (HT) patients who were treated in our hospital as outpatients were classified into the following categories: patients treated with at least 3 types of antihypertensive drugs including diuretic agents who were eligible for enrolment in SYMPLICITY HTN-Japan (SH-J) with an office systolic blood pressure (SBP) of ≥160 mmHg, who were ≤80 years of age, and an estimated glomerular filtration rate (eGFR) of ≥45 mL/min/1.73 m 2 (RHT-S); and patients who were treated similar medications and who were eligible for enrolment in REQUIRE, with an SBP of ≥150 mmHg, ≤75 years of age, and an eGFR of ≥40 mL/min/1.73 m 2 (RHT-R). We investigated the proportion of patients in each category. We also investigated HT patients (1,423 cases) who were enrolled in the Chikushi Anti-Hypertension Trial (CHAT), a research network that includes general practitioners. Results Eleven patients (1.1%) with RHT-S and 18 patients (1.8%) with RHT-R were identified. After the exclusion of patients with secondary HT and a diastolic blood pressure (DBP) of <90 mmHg (applied in REQUIRE), 5 patients (0.5%) with RHT-S and 4 patients (0.4%) with RHT-R remained. In the analysis of the CHAT study, only 2 (0.1%) patients with RHT-R remained. Conclusion The number of eligible patients in the REQUIRE trial was decreased, largely due to the strict age restriction and the new DBP limitation. The prevalence of eligible patients in REQUIRE was estimated to be approximately 0.5 to 0.8 times that in SH-J. Since patient enrollment will be difficult, drastic measures may be required to recruit eligible patients.

  9. Changes in ultrasound-assessed carotid intima-media thickness and plaque with a Mediterranean diet: a substudy of the PREDIMED trial.

    Science.gov (United States)

    Sala-Vila, Aleix; Romero-Mamani, Edwin-Saúl; Gilabert, Rosa; Núñez, Isabel; de la Torre, Rafael; Corella, Dolores; Ruiz-Gutiérrez, Valentina; López-Sabater, María-Carmen; Pintó, Xavier; Rekondo, Javier; Martínez-González, Miguel-Ángel; Estruch, Ramon; Ros, Emilio

    2014-02-01

    The Prevención con Dieta Mediterránea (PREDIMED) trial showed that a Mediterranean diet (MedDiet) supplemented with either extra virgin olive oil or 30 g/d of mixed nuts reduced incident cardiovascular events compared with a control (low fat) diet. The mechanisms of cardiovascular protection afforded by MedDiets remain to be uncovered. We assessed the effect of both supplemented MedDiets on internal carotid intima-media thickness (ICA-IMT) and plaque height, the ultrasound features that best predict future cardiovascular events, in subjects at high cardiovascular risk. In a PREDIMED subcohort (n=175), plaque height and carotid IMT of 3 prespecified segments (ICA, bifurcation, and common) were sonographically assessed at baseline and after intervention for a mean of 2.4 years. We evaluated 164 subjects with complete data. In a multivariate model, mean ICA-IMT progressed in the control diet group (mean [95% confidence interval], 0.052 mm [-0.014 to 0.118 mm]), whereas it regressed in the MedDiet+nuts group (-0.084 mm [-0.158 to -0.010 mm]; P=0.024 versus control). Similar results were observed for maximum ICA-IMT (control, 0.188 mm [0.077 to 0.299 mm]; MedDiet+nuts, -0.030 mm [-0.153 to 0.093 mm]; P=0.034) and maximum plaque height (control, 0.106 mm [0.001 to 0.210 mm]; MedDiet+nuts, -0.091 mm [-0.206 to 0.023 mm]; P=0.047). There were no changes in ICA-IMT or plaque after the MedDiet+extra virgin olive oil. Compared with a control diet, consumption of a MedDiet supplemented with nuts is associated with delayed progression of ICA-IMT and plaque. The results contribute mechanistic evidence for the reduction of cardiovascular events observed in the PREDIMED trial. http://www.controlled-trials.com. Unique identifier: ISRCTN35739639.

  10. Trauma Ultrasound.

    Science.gov (United States)

    Wongwaisayawan, Sirote; Suwannanon, Ruedeekorn; Prachanukool, Thidathit; Sricharoen, Pungkava; Saksobhavivat, Nitima; Kaewlai, Rathachai

    2015-10-01

    Ultrasound plays a pivotal role in the evaluation of acute trauma patients through the use of multi-site scanning encompassing abdominal, cardiothoracic, vascular and skeletal scans. In a high-speed polytrauma setting, because exsanguinations are the primary cause of trauma morbidity and mortality, ultrasound is used for quick and accurate detection of hemorrhages in the pericardial, pleural, and peritoneal cavities during the primary Advanced Trauma Life Support (ATLS) survey. Volume status can be assessed non-invasively with ultrasound of the inferior vena cava (IVC), which is a useful tool in the initial phase and follow-up evaluations. Pneumothorax can also be quickly detected with ultrasound. During the secondary survey and in patients sustaining low-speed or localized trauma, ultrasound can be used to help detect abdominal organ injuries. This is particularly helpful in patients in whom hemoperitoneum is not identified on an initial scan because findings of organ injuries will expedite the next test, often computed tomography (CT). Moreover, ultrasound can assist in detection of fractures easily obscured on radiography, such as rib and sternal fractures. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. Functional intravascular volume deficit in patients before surgery

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, M; Jørgensen, C C; Secher, N H

    2010-01-01

    limited data on the volume required to establish a maximal SV before the start of surgery. Therefore, we estimated the occurrence and size of the potential functional intravascular volume deficit in surgical patients. METHODS: Patients scheduled for mastectomy (n=20), open radical prostatectomy (n=20......BACKGROUND: Stroke volume (SV) maximization with a colloid infusion, referred to as individualized goal-directed therapy, improves outcome in high-risk surgery. The fraction of patients who need intravascular volume to establish a maximal SV has, however, not been evaluated, and there are only...... deficit. RESULTS: Forty-two (70%) of the patients needed volume to establish a maximal SV. For the patients needing volume, the required amount was median 200 ml (range 200-600 ml), with no significant difference between the three groups of patients. The required volume was >or=400 ml in nine patients (15...

  12. Newer techniques for intravascular and intraoperative neurointerventional procedures

    International Nuclear Information System (INIS)

    Higashida, R.T.; Halbach, V.V.; Hieshima, G.B.; Yang, P.

    1987-01-01

    A videotape demonstrating newer techniques used in intravascular and intraoperative embolization procedures will be presented. The authors discuss the use of some of the newer embolic agents, real-time digital subtraction angiography, roadmapping techniques, and the use of microcatheters and steerable micro guide wires, which has greatly facilitated neurovascullar embolization procedures and enhanced patient safety. A number of actual intraoperative and intravascular cases will be shown demonstrating treatment of vascular malformations of the brain and spinal cord, carotid cavernous sinus fistulas, aneurysms and dural arteriovenous malformations. The indications for treatment, patient selection, technical preparation and newer methodologies and approaches to complex vascular lesions of the brain and spinal cord are discussed in detail

  13. Cintilografia do miocárdio com tecnécio 99m-MIBI e administração de adenosina em portadores de doença arterial coronária: correlação dos resultados com a angiografia coronária e o ultra-som intracoronário Adenosine myocardial perfusion SPECT with Tc-99m-MIBI in patients with obstructive coronary artery disease: correlation between quantitative coronary angiography and intravascular ultrasound measurements

    Directory of Open Access Journals (Sweden)

    Luiz Eduardo Mastrocolla

    2006-01-01

    Full Text Available OBJETIVO: Estabelecer a correlação da cintilografia de perfusão do miocárdio (CPM com Tecnécio 99m-MIBI (MIBI e injeção de adenosina, empregando a angiografia coronária quantitativa (ACQ e o ultra-som intracoronário (UIC como comparação. MÉTODOS: Estudo de 70 pacientes com doença arterial coronária (DAC, encaminhados à CPM com MIBI e adenosina. As manifestações clínicas, do eletrocardiograma (ECG e os resultados das imagens foram correlacionadas às variáveis da análise visual e quantitativa da angiografia, bem como ao UIC. RESULTADOS: A média de idades foi de 60,6 anos, com 39 pacientes do sexo masculino. A angiografia coronária evidenciou estenose do diâmetro da luz (E% de 49,94% em 105 artérias, com reavaliação à ACQ em 83 artérias (79% e média de 44,20%, pOBJECTIVE: To correlate myocardial perfusion scintigraphy (MPS with Tc-99m-MIBI and adenosine infusion using quantitative coronary angiography (QCA and intravascular ultrasound (IVUS. METHODS: Seventy patients with coronary artery disease (CAD referred for myocardial perfusion scintigraphy (MPS with MIBI and adenosine were studied. Clinical, electrocardiographic (ECG, and scintigraphic findings were correlated with variables of visual and quantitative angiographic analysis, as well as to those of IVUS. RESULTS: The mean age of patients was 60.6 years, and 39 were male. Coronary angiography showed percentage of diameter stenosis (% DS of 49.94% in 105 arteries, 83 of which were re-evaluated by QCA (79%, mean of 44.20%, p<0.05. ST-segment depression during adenosine infusion was associated with higher degrees of % DS (55.0% vs. 47.8%, p<0.05. Scintigraphic ischemia was correlated with greater cross-sectional area of lumen obstruction by IVUS (% CSA. Clinical, ECG, and IVUS findings were considered together and expressed as global ischemic versus non-ischemic responses. Ischemia was associated with lower values of minimal lumen diameter (MLD and minimal lumen area

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... whether the object is solid or filled with fluid). In medicine, ultrasound is used to detect changes ... As the sound waves bounce off internal organs, fluids and tissues, the sensitive receiver in the transducer ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... whether the object is solid or filled with fluid). In medicine, ultrasound is used to detect changes ... As the sound waves bounce off internal organs, fluids and tissues, the sensitive receiver in the transducer ...

  16. Transvaginal ultrasound

    Science.gov (United States)

    ... bleeding and menstrual problems Certain types of infertility Ectopic pregnancy Pelvic pain Transvaginal ultrasound is also used during ... any medical emergency or for the diagnosis or treatment of any medical condition. A licensed physician should be consulted for ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... legs, neck and/or brain (in infants and children) or within various body organs such as the ... tumors other disorders of the urinary bladder In children, pelvic ultrasound can help evaluate: pelvic masses pelvic ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient consultation. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's ( ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... consist of a console containing a computer and electronics, a video display screen and a transducer that ... the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... a nodule found during a rectal exam, detect abnormalities, and determine whether the gland is enlarged. Ultrasound ... follow-up exam is done because a potential abnormality needs further evaluation with additional views or a ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test ... that allows the physician to see and evaluate blood flow through arteries and veins in the abdomen, ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... called color Doppler ultrasonography, is a special ultrasound technique that allows the physician to see and evaluate ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement ... by a computer, which in turn creates a real-time picture on the monitor. One or more ...

  5. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... uses sound waves to produce pictures of a man’s prostate gland and to help diagnose symptoms such ... also called transrectal ultrasound, provides images of a man's prostate gland and surrounding tissue. The exam typically ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Images related to Ultrasound - Prostate Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Images related to Ultrasound - Pelvis Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... quickly. The ultrasound exam room may have a television. Feel free to ask for your child's favorite ... display screen that looks like a computer or television monitor. The image is created based on the ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... tip of the transducer is smaller than the standard speculum used when performing a Pap test . A ... both sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... performed to detect: uterine anomalies uterine scars endometrial polyps fibroids cancer, especially in patients with abnormal uterine ... tumors other disorders of the urinary bladder In children, pelvic ultrasound can help evaluate: pelvic masses pelvic ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... be turned to either side to improve the quality of the images. After you are positioned on ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... than 20 minutes. top of page What will I experience during and after the procedure? Ultrasound exams in which the transducer is inserted into an opening of the body may produce minimal discomfort. If no biopsy is ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... called the Doppler effect). A computer collects and processes the sounds and creates graphs or color pictures ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a more in-depth investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of ... are sometimes the best way to see if treatment is working or if a finding is stable ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... such as the liver or kidneys. top of page What are some common uses of the procedure? In ... ask for your child's favorite channel. top of page What does the equipment look like? Ultrasound scanners consist ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... in the body. The principles are similar to sonar used by boats and submarines. The ultrasound image ... based on the same principles involved in the sonar used by bats, ships and fishermen. When a ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in the body. The principles are similar to sonar used by boats and submarines. The ultrasound image ... based on the same principles involved in the sonar used by bats, ships and fishermen. When a ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... prior to the exam. Bringing books, small toys, music or games can help to distract the child ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exam room may have a television. Feel free to ask for your child's favorite channel. top ... of North America, Inc. (RSNA). To help ensure current and accurate information, we do not permit copying ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown ... I prepare? You should wear comfortable, loose-fitting clothing for your ultrasound exam. You may need to ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown. ... I prepare? You should wear comfortable, loose-fitting clothing for your ultrasound exam. You may need to ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... radiation. This procedure requires little to no special preparation. Leave jewelry at home and wear loose, comfortable ... biopsy is planned. An enema may be taken two to four hours before the ultrasound to clean ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound Imaging? Men who have had the tail end of their bowel (rectum) removed during prior surgery ... or suggestion into the following text box: Comment: E-mail: Area code: Phone no: Thank you! Please ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... These exams are frequently used to evaluate the reproductive and urinary systems. Ultrasound is safe, noninvasive and ... identify and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... rectum. top of page What are some common uses of the procedure? A transrectal ultrasound of the ... the scanner by a cord. Some exams may use different transducers (with different capabilities) during a single ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the returning echoes from the tissues in the body. The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible on a video display screen ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the returning echoes from the tissues in the body. The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible on a video display screen ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries in planes that ... a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams, you will be positioned lying face-up on an examination table that can be tilted ... you at the conclusion of your examination. Follow-up examinations may be necessary. Your doctor will explain ...

  16. Thyroid ultrasound

    Science.gov (United States)

    ... Thyroid physiology and diagnostic evaluation of patients with thyroid disorders. In: Melmed S, Polonsky KS, Larsen PR, Kronenberg HM, eds. Williams Textbook of Endocrinology . 13th ed. Philadelphia, PA: Elsevier; 2016:chap 11. ... Thyroid Tests Read more Ultrasound ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... to investigate a nodule found during a rectal exam, detect abnormalities, and determine whether the gland is ... a man's prostate gland and surrounding tissue. The exam typically requires insertion of an ultrasound probe into ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... nodule felt by a physician during a routine physical exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... physician during a routine physical exam or prostate cancer screening exam. an elevated blood test result. difficulty ... vessels or to detect abnormal masses, such as tumors. In an ultrasound examination, a transducer both sends ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... rectum. top of page What are some common uses of the procedure? A transrectal ultrasound of the ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the rectal wall is relatively insensitive to the pain in the region of the prostate. A biopsy ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... fluid). In medicine, ultrasound is used to detect changes in appearance, size or contour of organs, tissues, ... the sensitive receiver in the transducer records tiny changes in the sound's pitch and direction. These signature ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... fluid). In medicine, ultrasound is used to detect changes in appearance, size or contour of organs, tissues, ... the sensitive receiver in the transducer records tiny changes in the sound's pitch and direction. These signature ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... arteries and veins in the abdomen, arms, legs, neck and/or brain (in infants and children) or ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... in x-rays ), thus there is no radiation exposure to the patient. Because ultrasound images are captured ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is sometimes seen in infections top of page How should I prepare? You should wear comfortable, loose- ... sheath and lubricated before insertion. top of page How does the procedure work? Ultrasound imaging is based ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gland for later laboratory testing. top of page How should I prepare? You should wear comfortable, loose- ... and lubricated with a gel. top of page How does the procedure work? Ultrasound imaging is based ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view ... detect: uterine anomalies uterine scars endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to the child prior to the exam. Bringing books, small toys, music or games can help to ... the ultrasound signal to return from the area within the patient that is being examined to the ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... prior to the exam. Bringing books, small toys, music or games can help to distract the child ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... systems. Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. You may be asked to drink water prior to the examination to fill your bladder. ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the prostate is enlarged, also known as benign prostatic hyperplasia (BPH) , with measurements acquired as needed for any ... size with caption Related Articles and Media Benign Prostatic Hyperplasia (BPH) (Enlargement of the Prostate) Prostate Cancer Ultrasound- ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. For ... make secure contact with the body and eliminate air pockets between the transducer and the skin that ...

  3. Breast ultrasound

    Science.gov (United States)

    ... such as: Cysts, which are, fluid-filled sacs Fibroadenomas , which are, noncancerous solid growths Lipomas, which are, noncancerous fatty lumps that can occur anywhere in the body, including the breasts Breast cancers can also be seen with ultrasound. ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... abnormal area in the prostate gland for later laboratory testing. top of page How should I prepare? ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... frequently used to evaluate the reproductive and urinary systems. Ultrasound is safe, noninvasive and does not use ... and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  10. Acute renal failure related to oxaliplatin-induced intravascular hemolysis.

    Science.gov (United States)

    Ulusakarya, Ayhan; Misra, Srimanta; Haydar, Mazen; Habert, Hélène; Castagne, Vincent; Gumus, Yusuf; Delmas-Marsalet, Béatrice; Machover, David

    2010-12-01

    Oxaliplatin is an effective chemotherapeutic agent frequently used in the treatment of colorectal carcinoma. Rare cases of renal failure and hemolytic reactions have been reported as separate side effects of oxaliplatin. Here we present a clinical picture of immune-related intravascular hemolysis and acute tubular necrosis in a patient receiving this drug. This case suggests a mechanistic explanation of renal failure in patients treated with oxaliplatin.

  11. Renal artery stenting with noninvasive duplex ultrasound follow-up: 3-year results from the RENAISSANCE renal stent trial.

    Science.gov (United States)

    Rocha-Singh, Krishna; Jaff, Michael R; Lynne Kelley, E

    2008-11-15

    The multicenter, single-arm RENAISSANCE trial evaluated outcomes in patients with progressive atherosclerotic renal artery stenosis (ARAS) treated with the Express Renal Premounted Stent System (Boston Scientific, Natick, MA). Renal artery stenting may prevent the morbidity and mortality of surgical revascularization and high restenosis rates of percutaneous renal angioplasty (PTRA). Renal artery duplex ultrasonography (DUS) offers an alternative to traditional invasive poststenting angiographic surveillance, though concordance with angiography for in-stent restenosis has yet to be validated independently. RENAISSANCE enrolled 100 patients (117 lesions) with de novo or restenotic ostial atherosclerotic lesions or=4.0 and or=70%. The primary endpoint, 9-month binary restenosis, was compared to an objective performance criterion (OPC) of 40% for published PTRA results. Follow-up was conducted through 3 years. Technical and procedural success was both 99%. Follow-up angiography, triggered clinically or by ultrasonography, revealed 21.3% binary restenosis at 9 months, which was superior to the OPC (P RENAISSANCE demonstrates that renal artery stenting is superior to the prespecified OPC at 9 months, and also shows that DUS can accurately identify in-stent restenosis. (c) 2008 Wiley-Liss, Inc.

  12. The effect of continuous ultrasound on chronic non-specific low back pain: a single blind placebo-controlled randomized trial

    Science.gov (United States)

    2012-01-01

    Background Non-specific chronic low back pain (NSCLBP) is one of the most common musculoskeletal disorders around the world including Iran. One of the most widely used modalities in the field of physiotherapy is therapeutic ultrasound (US). Despite its common use, there is still inconclusive evidence to support its effectiveness in patients with NSCLBP. The objective of this study was to evaluate the effect of continuous US compared with placebo US additional to exercise therapy for patients with NSCLBP. Methods In this single blind placebo controlled study, 50 patients with NSCLBP were randomized into two treatment groups: 1) continuous US (1 MHz &1.5 W/cm2) plus exercise 2) placebo US plus exercise. Patients received treatments for 4 weeks, 10 treatment sessions, 3 times per week, every other day. Treatment effects were assessed in terms of primary outcome measures: 1) functional disability, measured by Functional Rating Index, and 2) global pain, measured by a visual analog scale. Secondary outcome measures were lumbar flexion and extension range of motion (ROM), endurance time and rate of decline in median frequency of electromyography spectrum during a Biering Sorensen test. All outcome variables were measured before, after treatment, and after one-month follow-up. An intention to treat analysis was performed. Main effects of Time and Group as well as their interaction effect on outcome measures were investigated using repeated measure ANOVA. Results Analysis showed that both groups had improved regarding function (FRI) and global pain (VAS) (P .05). Improvement in function and lumbar ROM as well as endurance time were significantly greater in the group receiving continuous US (P exercise program significantly improved function, lumbar ROM and endurance time. Further studies including a third group of only exercise and no US can establish the possible effects of placebo US. Trial registration NTR2251 PMID:23031570

  13. Analgesic efficacy of ultrasound guided transversus abdominis plane block versus local anesthetic infiltration in adult patients undergoing single incision laparoscopic cholecystectomy: A randomized controlled trial.

    Science.gov (United States)

    Bava, Ejas P; Ramachandran, Rashmi; Rewari, Vimi; Chandralekha; Bansal, Virinder Kumar; Trikha, Anjan

    2016-01-01

    Transversus abdominis plane (TAP) block has been used to provide intra- and post-operative analgesia with single incision laparoscopic (SIL) bariatric and gynecological surgery with mixed results. Its efficacy in providing analgesia for SIL cholecystectomy (SILC) via the same approach remains unexplored. The primary objective of our study was to compare the efficacy of bilateral TAP block with local anesthetic infiltration for perioperative analgesia in patients undergoing SILC. This was a prospective, randomized, controlled, double-blinded trial performed in a tertiary care hospital. Forty-two patients undergoing SILC were randomized to receive either ultrasound-guided (USG) bilateral mid-axillary TAP blocks with 0.375% ropivacaine or local anesthetic infiltration of the port site. The primary outcome measure was the requirement of morphine in the first 24 h postoperatively. The data were analyzed using t -test, Mann-Whitney test or Chi-square test. The 24 h morphine requirement (mean ± standard deviation) was 34.57 ± 14.64 mg in TAP group and 32.76 ± 14.34 mg in local infiltration group ( P = 0.688). The number of patients requiring intraoperative supplemental fentanyl in TAP group was 8 and in local infiltration group was 16 ( P = 0.028). The visual analog scale scores at rest and on coughing were significantly higher in the local infiltration group in the immediate postoperative period ( P = 0.034 and P = 0.007, respectively). USG bilateral TAP blocks were not effective in decreasing 24 h morphine requirement as compared to local anesthetic infiltration in patients undergoing SILC although it provided some analgesic benefit intraoperatively and in the initial 4 h postoperatively. Hence, the benefits of TAP blocks are not worth the effort and time spent for administering them for this surgery.

  14. Asian-variant intravascular lymphoma in the African race

    Directory of Open Access Journals (Sweden)

    Holly Geyer

    2012-03-01

    Full Text Available Intravascular large B-cell lymphoma (IVLBCL is an exceptionally rare form of non- Hodgkin lymphoma (NHL distinguished by the preferential growth of neoplastic cells within blood vessel lumen. Challenging to detect and deemed disseminated at diagnosis, this condition is characterized by a highly aggressive, inconspicuous course with a high mortality rate. We describe the case of a 48 year-old African-American female presenting with a two month history of low-grade fevers and malaise. Laboratory data was notable for anemia, thrombocytopenia, elevated liver function tests, and hematuria. An extensive workup for infectious, rheumatologic and malignant causes was negative. Her symptoms progressed and within two weeks, she was admitted for disseminated intravascular coagulation (DIC. Her course was complicated by diffuse pulmonary hemorrhage and ultimately, care was withdrawn. Autopsy identified widespread CD-20 positive intravascular large B-cell lymphoma with significant hepatosplenic involvement, characteristic of the Asian variant IVLBCL. This case uniquely highlights development of the Asian variant IVLBVL in a previously undescribed race. Identified by its intraluminal vascular growth pattern, IVLBCL generally spares lymphatic channels. Diagnosis and differentiation of this condition from other hematological malignancies via skin, visceral and bone marrow biopsy is imperative as anthracycline-containing chemotherapies may significantly improve clinical outcomes. This article outlines the common presentation, natural course, and treatment options of IVLBCL, along with the histopathology, immunohistochemistry, and chromosomal aberrations common to this condition.

  15. Disseminated intravascular coagulation and massive obstetric hemorrhage. Management dilemma.

    Science.gov (United States)

    Al-Nuaim, Lulu A; Mustafa, Mohamed S; Abdel Gader, Abdel Galil M

    2002-06-01

    The objective of this retrospective study is to reflect on our experience on an optimal management for major postpartum hemorrhage, which would prevent the occurrence and complications of disseminated intravascular coagulation and minimize maternal mortality and morbidity. Ten cases out of the 30,000 of total deliveries of severe obstetric hemorrhage associated with disseminated intravascular coagulation were studied. This study was carried out over a 7 year period, October 1988 through to September 1995, at the Obstetric Unit, King Khalid University Teaching Hospital, Riyadh, Kingdom of Saudi Arabia. All of the 10 women received packed red blood cells, 8 had fresh frozen plasma, and 6 received platelet transfusion. The 10 cases developed disseminated intravascular coagulation following medical and surgical management, all women needed hysterectomy, 4 subtotal, 6 total, and 5 women had relaparotomy and pelvic packing. Two had bladder injuries. There was no maternal death. An early resort to hysterectomy when conservative measures fail, will minimize maternal morbidity and mortality. In case of continuous bleeding after hysterectomy, pelvic packing proved to be effective.

  16. Multicenter Analysis of Immune Biomarkers and Heart Transplant Outcomes: Results of the Clinical Trials in Organ Transplantation-05 Study.

    Science.gov (United States)

    Starling, R C; Stehlik, J; Baran, D A; Armstrong, B; Stone, J R; Ikle, D; Morrison, Y; Bridges, N D; Putheti, P; Strom, T B; Bhasin, M; Guleria, I; Chandraker, A; Sayegh, M; Daly, K P; Briscoe, D M; Heeger, P S

    2016-01-01

    Identification of biomarkers that assess posttransplant risk is needed to improve long-term outcomes following heart transplantation. The Clinical Trials in Organ Transplantation (CTOT)-05 protocol was an observational, multicenter, cohort study of 200 heart transplant recipients followed for the first posttransplant year. The primary endpoint was a composite of death, graft loss/retransplantation, biopsy-proven acute rejection (BPAR), and cardiac allograft vasculopathy (CAV) as defined by intravascular ultrasound (IVUS). We serially measured anti-HLA- and auto-antibodies, angiogenic proteins, peripheral blood allo-reactivity, and peripheral blood gene expression patterns. We correlated assay results and clinical characteristics with the composite endpoint and its components. The composite endpoint was associated with older donor allografts (p heart transplantation. © Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.

  17. Optimal timing for intravascular administration set replacement.

    Science.gov (United States)

    Ullman, Amanda J; Cooke, Marie L; Gillies, Donna; Marsh, Nicole M; Daud, Azlina; McGrail, Matthew R; O'Riordan, Elizabeth; Rickard, Claire M

    2013-09-15

    The tubing (administration set) attached to both venous and arterial catheters may contribute to bacteraemia and other infections. The rate of infection may be increased or decreased by routine replacement of administration sets. This review was originally published in 2005 and was updated in 2012. The objective of this review was to identify any relationship between the frequency with which administration sets are replaced and rates of microbial colonization, infection and death. We searched The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 6), MEDLINE (1950 to June 2012), CINAHL (1982 to June 2012), EMBASE (1980 to June 2012), reference lists of identified trials and bibliographies of published reviews. The original search was performed in February 2004. We also contacted researchers in the field. We applied no language restriction. We included all randomized or controlled clinical trials on the frequency of venous or arterial catheter administration set replacement in hospitalized participants. Two review authors assessed all potentially relevant studies. We resolved disagreements between the two review authors by discussion with a third review author. We collected data for seven outcomes: catheter-related infection; infusate-related infection; infusate microbial colonization; catheter microbial colonization; all-cause bloodstream infection; mortality; and cost. We pooled results from studies that compared different frequencies of administration set replacement, for instance, we pooled studies that compared replacement ≥ every 96 hours versus every 72 hours with studies that compared replacement ≥ every 48 hours versus every 24 hours. We identified 26 studies for this updated review, 10 of which we excluded; six did not fulfil the inclusion criteria and four did not report usable data. We extracted data from the remaining 18 references (16 studies) with 5001 participants: study designs included neonate and adult

  18. Dry weight assessment by combined ultrasound and bioimpedance monitoring in low cardiovascular risk hemodialysis patients: a randomized controlled trial.

    Science.gov (United States)

    Siriopol, Dimitrie; Onofriescu, Mihai; Voroneanu, Luminita; Apetrii, Mugurel; Nistor, Ionut; Hogas, Simona; Kanbay, Mehmet; Sascau, Radu; Scripcariu, Dragos; Covic, Adrian

    2017-01-01

    Fluid overload is associated with adverse outcomes in hemodialysis (HD) patients. The precise assessment of hydration status in HD patients remains a major challenge for nephrologists. Our study aimed to explore whether combining two bedside methods, lung ultrasonography (LUS) and bioimpedance, may provide complementary information to guide treatment in specific HD patients. In total, 250 HD patients from two dialysis units were included in this randomized clinical trial. Patients were randomized 1:1 to have a dry weight assessment based on clinical (control) or LUS with bioimpedance in case of clinical hypovolemia (active)-guided protocol. The primary outcome was to assess the difference between the two groups on a composite of all-cause mortality and first cardiovascular event (CVE)-including death, stroke, and myocardial infarction. During a mean follow-up period was 21.3 ± 5.6 months, there were 54 (21.6%) composite events in the entire population. There was a nonsignificant 9% increase in the risk of this outcome in the active arm (HR = 1.09, 95% CI 0.64-1.86, p = 0.75). Similarly, there were no differences between the two groups when analyzing separately the all-cause mortality and CVE outcomes. However, patients in the active arm had a 19% lower relative risk of pre-dialytic dyspnea (rate ratio-0.81, 95% CI 0.68-0.96), but a 26% higher relative risk of intradialytic cramps (rate ratio-1.26, 95% CI 1.16-1.37). This study shows that a LUS-bioimpedance-guided dry weight adjustment protocol, as compared to clinical evaluation, does not reduce all-cause mortality and/or CVE in HD patients. A fluid management protocol based on bioimpedance with LUS on indication might be a better strategy.

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... What are the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and ... be heard with every heartbeat. top of page What are some common uses of the procedure? Ultrasound ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements ...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart ... Articles and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview ...

  3. Penetration of an artificial arterial thromboembolism in a live animal using an intravascular therapeutic microrobot system.

    Science.gov (United States)

    Jeong, Semi; Choi, Hyunchul; Go, Gwangjun; Lee, Cheong; Lim, Kyung Seob; Sim, Doo Sun; Jeong, Myung Ho; Ko, Seong Young; Park, Jong-Oh; Park, Sukho

    2016-04-01

    The biomedical applications of wireless robots are an active area of study. In addition to moving to a target lesion, wireless locomotive robots can deliver a therapeutic drug for a specific disease. Thus, they hold great potential as therapeutic devices in blood vessel diseases, such as thrombi and occlusions, and in other diseases, such as cancer and inflammation. During a percutaneous coronary intervention (PCI), surgeons wear a heavy shielding cloth. However, they cannot escape severe radiation exposure owing to unstable shielding. They may also suffer from joint pains because of the weight of the shielding cloth. In addition, the catheters in PCIs are controlled by the surgeon's hand. Thus, they lack steering ability. A new intravascular therapeutic system is needed to address these problems in conventional PCIs. We developed an intravascular therapeutic microrobot system (ITMS) using an electromagnetic actuation (EMA) system with bi-plane X-ray devices that can remotely control a robot in blood vessels. Using this proposed ITMS, we demonstrated the locomotion of the robot in abdominal and iliac arteries of a live pig by the master-slave method. After producing an arterial thromboembolism in a live pig in a partial iliac artery, the robot moved to the target lesion and penetrated by specific motions (twisting and hammering) of the robot using the proposed ITMS. The results reveal that the proposed ITMS can realize stable locomotion (alignment and propulsion) of a robot in abdominal and iliac arteries of a live pig. This can be considered the first preclinical trial of the treatment of an artificial arterial thromboembolism by penetration of a blood clot. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Therapeutic ultrasound

    International Nuclear Information System (INIS)

    Crum, Lawrence A

    2004-01-01

    The use of ultrasound in medicine is now quite commonplace, especially with the recent introduction of small, portable and relatively inexpensive, hand-held diagnostic imaging devices. Moreover, ultrasound has expanded beyond the imaging realm, with methods and applications extending to novel therapeutic and surgical uses. These applications broadly include: tissue ablation, acoustocautery, lipoplasty, site-specific and ultrasound mediated drug activity, extracorporeal lithotripsy, and the enhancement of natural physiological functions such as wound healing and tissue regeneration. A particularly attractive aspect of this technology is that diagnostic and therapeutic systems can be combined to produce totally non-invasive, imageguided therapy. This general lecture will review a number of these exciting new applications of ultrasound and address some of the basic scientific questions and future challenges in developing these methods and technologies for general use in our society. We shall particularly emphasize the use of High Intensity Focused Ultrasound (HIFU) in the treatment of benign and malignant tumors as well as the introduction of acoustic hemostasis, especially in organs which are difficult to treat using conventional medical and surgical techniques. (amum lecture)

  5. Efficacy of triamcinolone acetate and methylprednisolone acetonide for intrabursal injection after ultrasound-guided percutaneous treatment in painful shoulder calcific tendonitis: a randomized controlled trial.

    Science.gov (United States)

    Battaglia, Milva; Guaraldi, Federica; Gori, Davide; Castiello, Emanuela; Arvat, Emanuela; Sudanese, Alessandra

    2017-08-01

    Background Ultrasound-guided percutaneous irrigation of calcific tendinopathy (US-PICT) with intrabursal steroid injection is an elective treatment for painful rotator cuff calcific tendinopathy. Purpose To compare the efficacy of post-US-PICT intrabursal 40 mg injection of triamcinolone acetonide (TA) versus methylprednisolone acetate (MA). Material and Methods Forty patients (22 women; mean age 48.7 ± 7.2 years) with painful shoulder calcific tendinopathy, treated with TA or MA injected intrabursally after US-PICT, were included in this randomized controlled trial. At baseline and after 1, 7, 15, 30, 45, and 180 days, patients underwent US and clinical examination, using Constant (CS) and VAS (VS) scores. Complications and analgesic use were also recorded. Results Compared to baseline, at the 45-day follow-up, TA and MA group showed a similar improvement (Δ) in CS (42 ± 10 versus 36 ± 9 points) and VS (-4.4 ± 1.3 versus -3.6 ± 1.3 points). At the 180-day follow-up, the improvement was higher in TA versus MA (ΔCS: 53 ± 7 versus 44 ± 7 points; ΔVS: -4.9 ± 1.1 versus -3.9 ± 1 points). Multivariate analysis showed a mean CS higher ( P = 0.02) in TA versus MA group, while VS was similar. TA had a 5 × higher ( P = 0.007) chance of reaching complete remission (CS = 100 points) than MA group. A progressive decrease in analgesic use, concomitant to a significant and similar reduction of bursitis and calcifications, was observed in both groups. No major complications occurred. Conclusion Two-needle US-PICT with intrabursal steroid injection is safe and effective. The chance of reaching better scores and, even more important for a clinical perspective, of functional recovery, is higher in patients treated with TA than MA.

  6. Teaching aseptic technique for central venous access under ultrasound guidance: a randomized trial comparing didactic training alone to didactic plus simulation-based training.

    Science.gov (United States)

    Latif, Rana K; Bautista, Alexander F; Memon, Saima B; Smith, Elizabeth A; Wang, Chenxi; Wadhwa, Anupama; Carter, Mary B; Akca, Ozan

    2012-03-01

    Our goal was to determine whether simulation combined with didactic training improves sterile technique during ultrasound (US)-guided central venous catheter (CVC) insertion compared with didactic training alone among novices. We hypothesized that novices who receive combined didactic and simulation-based training would perform similarly to experienced residents in aseptic technique, knowledge, and perception of comfort during US-guided CVC insertion on a simulator. Seventy-two subjects were enrolled in a randomized, controlled trial of an educational intervention. Fifty-four novices were randomized into either the didactic group or the simulation combined with didactic group. Both groups received didactic training but the simulation combined with didactic group also received simulation-based CVC insertion training. Both groups were tested by demonstrating US-guided CVC insertion on a simulator. Aseptic technique was scored on 8 steps as "yes/no" and also using a 7-point Likert scale with 7 being "excellent technique" by a rater blinded to subject randomization. After initial testing, the didactic group was offered simulation-based training and retesting. Both groups also took a pre- and posttraining test of knowledge and rated their comfort with US and CVC insertion pre- and posttraining on a 5-point Likert scale. Subsequently, 18 experienced residents also took the test of knowledge, rated their comfort level, and were scored while performing aseptic US-guided CVC insertion using a simulator. The simulation combined with didactic group achieved a 167% (95% confidence interval [CI] 133%-167%) incremental increase in yes/no scores and 115% (CI 112%-127%) incremental increase in Likert scale ratings on aseptic technique compared with novices in the didactic group. Compared with experienced residents, simulation combined with didactic trained novices achieved an increase in aseptic scores with a 33.3% (CI 16.7%-50%) increase in yes/no ratings and a 20% (CI 13

  7. Quantification of iliac artery stenoses: a methodological comparative study between intravascular ultrasound, arteriography and duplex scanning

    DEFF Research Database (Denmark)

    Vogt, K C; Rasmussen, John Bøje Grønvall; Skovgaard, Lene T

    1998-01-01

    66 y, admitted for either PTA (n=18) or femoro-femoral crossover bypass surgery (n=20), were examined by IVUS, single plane arteriography and duplex scanning. The predictive value, sensitivity, specificity and kappa value of IVUS were higher than the corresponding values for arteriography. Logistic...... regression analysis found that IVUS had a predictive value (p=0.0003) for diagnosing significant stenosis as defined by duplex scanning, but arteriography did not (p=0.1). However, this difference in usefulness as predictors did not reach significance. The agreement between arteriography and IVUS...... was relatively good. The conclusion is that IVUS seems to be superior to single-plane arteriography in predicting hemodynamically significant stenoses as defined by duplex scanning....

  8. Finite element modeling and intravascular ultrasound elastography of vulnerable plaques: parameter variation.

    NARCIS (Netherlands)

    Baldewsing, R.A.; Korte, C.L. de; Schaar, J.A.; Mastik, F.; Steen, A.F.W. van der

    2004-01-01

    BACKGROUND AND GOAL: More than 60% of all myocardial infarction is caused by rupture of a vulnerable plaque. A vulnerable plaque can be described as a large, soft lipid pool covered by a thin fibrous cap. Plaque material composition, geometry, and inflammation caused by infiltration of macrophages

  9. Intravascular ultrasound-guided stenting of left main stem dissection after medtronic corevalve implantation

    NARCIS (Netherlands)

    N.M. van Mieghem (Nicolas); P.P.T. de Jaegere (Peter)

    2013-01-01

    textabstractTranscatheter aortic valve implantation (TAVI) implies the introduction, positioning, and deployment of a stented bioprosthesis in the (calcified) native aortic valve. We report an at first glance uneventful TAVI with the Medtronic Corevalve System, which was followed by transient

  10. Histamine release and endothelial leakage from an intravascular contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Raininko, R.

    1981-04-01

    The endothelial injury produced by meglumine iodamide was studied in the rat aorta. A mixture of blood and contrast medium was more toxic to the endothelium than the pure contrast agent. This difference disappeared after premedication with antihistamine, which did not affect the injury produced by the pure contrast agent. Meglumine iodamide appears to cause a release of histamine from blood but not from the aortic endothelium nor from surrounding tissues in amounts demonstrable by this method. Leucocytes are a source of histamine after intravascular contrast medium administration.

  11. Retinal and choroidal intravascular spectral-domain optical coherence tomography

    DEFF Research Database (Denmark)

    Willerslev, Anne; Li, Xiao Qiang; Cordtz, Peter

    2014-01-01

    on longitudinal scans and a figure-of-eight configuration on cross-sectional scans. Intravascular reflectivity decreased with increasingly oblique angles of observation and was absent when blood flow was parallel to the line of sight. The high blood flow in the choroidal vessels in healthy subjects and the low......-OCT profile of the blood column in retinal vessels with normal blood flow. Both structure and total reflectivity faded when blood flow was lower or higher than normal or at oblique angles to the line of sight. In conclusion, SD-OCT scans of the vessels in the posterior pole of the eye may assist the clinical...

  12. Why Have So Many Intravascular Glucose Monitoring Devices Failed?

    Science.gov (United States)

    Smith, John L; Rice, Mark J

    2015-07-01

    Secondary to the inherent limitations of both point-of-care and central laboratory glucose technologies, continuous glucose measurement has recently enjoyed a high level of investment. Because of the perceived advantages by some of measuring in the intravascular space compared to the subcutaneous tissue, a number of technologies have been developed. In this review, we evaluate nine systems that have shown promise, although only one of these has been cleared for sale in the United States. The detection methodology, regulatory status, technical issues, and company circumstance surrounding each technology are examined. © 2015 Diabetes Technology Society.

  13. Assessing mechanical properties with intravascular or endoscopic optical coherence tomography

    Science.gov (United States)

    Lamouche, G.; Azarnoush, H.; Vergnole, S.; Pazos, V.; Bisaillon, C.-E.; Debergue, P.; Boulet, B.; Diraddo, R.

    2011-03-01

    We explore the potential of intravascular or endoscopic optical coherence tomography (OCT) to extract relevant mechanical properties of a tissue deformed by an inflating balloon. Tubular OCT phantoms with different mechanical properties are fabricated. The phantoms are deformed by an inflating balloon, and the deformation is monitored with OCT. A quantitative description of the phantom deformation is obtained by segmenting the OCT images. Two strategies to extract the mechanical properties from this quantitative data are presented: by comparing to a finite-element simulation and by performing a mechanical analysis.

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... end of their bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... special preparation. You may be asked to drink water prior to the examination to fill your bladder. Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown. What is Pelvic Ultrasound Imaging? What are some common uses of the procedure? How should I prepare? What ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... pitch) and time it takes for the ultrasound signal to return from the area within the patient that is being examined to the transducer (the device placed on the patient's skin to send and receive the returning sound waves), as well as the type of body ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... pitch) and time it takes for the ultrasound signal to return from the area within the patient that is being examined to the transducer (the device placed on the patient's skin to send and receive the returning sound waves), as well as the type of body ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... do not use ionizing radiation (as used in x-rays ), thus there is no radiation exposure to the ... tissues that do not show up well on x-ray images. Ultrasound is the preferred imaging modality for ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... do not use ionizing radiation (as used in x-rays ), thus there is no radiation exposure to the ... tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the pelvis uses sound waves to produce pictures of the structures and organs in the lower abdomen and pelvis. There are three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... BPH) , with measurements acquired as needed for any treatment planning. detect an abnormal growth within the prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of the prostate gland is typically used to help diagnose symptoms such as: a nodule felt by a physician ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the equipment look like? How does the procedure work? How is the procedure performed? What will I experience during and after the procedure? Who interprets the results and how do I get them? What are the benefits vs. risks? What are the limitations of Pelvic Ultrasound Imaging? ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the equipment look like? How does the procedure work? How is the procedure performed? What will I experience during and after the procedure? Who interprets the results and how do I get them? What are the benefits vs. risks? What are the limitations of Prostate Ultrasound Imaging? ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then listens for the returning echoes from ... ultrasound , there are no known harmful effects on humans. top ... waves as they pass deeper into the body and need to be returned to the transducer ...

  7. Hip Ultrasound

    Science.gov (United States)

    ... prior to the exam. Bringing books, small toys, music or games can help to distract the child and make the time ... back or side. Almost all of the ultrasound studies of infants and ... studied. The gel will help the transducer make secure contact with the body ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... No Please type your comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: Thank you! Please help us improve RadiologyInfo.org by taking our brief survey: Survey Do ... Benign Prostatic Hyperplasia (BPH) (Enlargement of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... 20 minutes. top of page What will I experience during and after the procedure? Ultrasound exams in ... areas. Outside links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo. ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... symptoms such as difficulty urinating or an elevated blood test result. It’s also used to investigate a nodule ... exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in which needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images can help the physician to see and evaluate: blockages to blood flow (such as clots) narrowing of vessels tumors ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide procedures such as needle biopsies , in which a needle is used to sample cells (tissue) from an abnormal area in the ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... time. Follow-up examinations are sometimes the best way to see if treatment is working or if a finding is stable or changed over time. top of page What are the benefits vs. ... not show up well on x-ray images. Ultrasound causes no health problems and may ...

  14. Carotid Ultrasound

    Science.gov (United States)

    ... trials from ClinicalTrials.gov . Visit Children and Clinical Studies to hear experts, parents, and children talk about their experiences with clinical research. More Information Related Health Topics Atherosclerosis Carotid Artery Disease Carotid Endarterectomy High Blood Pressure ...

  15. OSPACS: Ultrasound image management system

    Directory of Open Access Journals (Sweden)

    Bessant Conrad

    2008-06-01

    Full Text Available Abstract Background Ultrasound scanning uses the medical imaging format, DICOM, for electronically storing the images and data associated with a particular scan. Large health care facilities typically use a picture archiving and communication system (PACS for storing and retrieving such images. However, these systems are usually not suitable for managing large collections of anonymized ultrasound images gathered during a clinical screening trial. Results We have developed a system enabling the accurate archiving and management of ultrasound images gathered during a clinical screening trial. It is based upon a Windows application utilizing an open-source DICOM image viewer and a relational database. The system automates the bulk import of DICOM files from removable media by cross-validating the patient information against an external database, anonymizing the data as well as the image, and then storing the contents of the file as a field in a database record. These image records may then be retrieved from the database and presented in a tree-view control so that the user can select particular images for display in a DICOM viewer or export them to external media. Conclusion This system provides error-free automation of ultrasound image archiving and management, suitable for use in a clinical trial. An open-source project has been established to promote continued development of the system.

  16. Intravascular stenting (IVaS) method for fingertip replantation.

    Science.gov (United States)

    Narushima, Mitsunaga; Mihara, Makoto; Koshima, Isao; Gonda, Koichi; Takuya, Iida; Kato, Harunosuke; Nakanishi, Kenji; Yamamoto, Yusuke; Araki, Jun; Abe, Hiroaki; Mundinger, Gerhard S; Kikuchi, Kazuki; Uehara, Eri

    2009-01-01

    Remarkable progress has been made in microsurgery. However, fingertip replantation following amputation has not gained much popularity because of its technical difficulty. We have developed the intravascular stenting (IVaS) method, in which a nylon monofilament is placed inside the vessel lumen to act as a temporary stent, facilitating anastomosis completion. This report describes 7 fingertip replantations using the IVaS method. Intravascular stent size varied from 4-0 to 6-0 (0.199-0.07 mm diameter). There were no cases in which the back wall of a vessel became inadvertently caught in the anastomosis. The overall survival rate for distal digital replants was 85% (6/7 replants). It is very difficult to evenly anastomose vessels of differing diameter, especially on a supermicrosurgical scale. In this respect, the IVaS method plays a role in stably anchoring the 2 vessel ends, allowing for the even spacing of suture knots, even in vessels of different caliber. Because of its ease of use and exactitude, many surgeons may be able to use the IVaS method to reliably complete small anastomoses in fingertip replantations.

  17. Late adverse reactions to intravascular iodinated contrast media

    International Nuclear Information System (INIS)

    Webb, Judith A.W.; Stacul, Fulvio; Thomsen, Henrik S.; Morcos, Sameh K.

    2003-01-01

    Late adverse reactions to intravascular iodinated contrast media are defined as reactions occurring 1 h to 1 week after contrast medium injection. They have received increasing interest over the past decade, but their prevalence remains uncertain and their pathophysiology is not fully understood. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and to issue guidelines. An extensive literature search was carried out and summarized in a report. Based on the available information, simple guidelines have been drawn up. The report and guidelines were discussed at the 8th European Symposium on Urogenital Radiology in Genoa. Late adverse reactions after intravascular iodinated contrast medium include symptoms such as nausea, vomiting, headache, itching, skin rash, musculoskeletal pain, and fever. A significant proportion of these reactions is unrelated to the contrast medium; however, allergy-like skin reactions are well-documented side effects of contrast media with an incidence of approximately 2%. Late reactions appear to be commoner after non-ionic dimers. The majority of late skin reactions after contrast medium exposure are probably T-cell-mediated allergic reactions. Patients at increased risk of late skin reactions are those with a history of previous contrast medium reaction and those on interleukin-2 treatment. Most skin reactions are self-limiting and resolve within a week. Management is symptomatic and similar to the management of other drug-induced skin reactions. (orig.)

  18. An Implantable Intravascular Pressure Sensor for a Ventricular Assist Device

    Directory of Open Access Journals (Sweden)

    Luigi Brancato

    2016-08-01

    Full Text Available The aim of this study is to investigate the intravascular application of a micro-electro-mechanical system (MEMS pressure sensor to directly measure the hemodynamic characteristics of a ventricular assist device (VAD. A bio- and hemo-compatible packaging strategy is implemented, based on a ceramic thick film process. A commercial sub-millimeter piezoresistive sensor is attached to an alumina substrate, and a double coating of polydimethylsiloxane (PDMS and parylene-C is applied. The final size of the packaged device is 2.6 mm by 3.6 mm by 1.8 mm. A prototype electronic circuit for conditioning and read-out of the pressure signal is developed, satisfying the VAD-specific requirements of low power consumption (less than 14.5 mW in continuous mode and small form factor. The packaged sensor has been submitted to extensive in vitro tests. The device displayed a temperature-independent sensitivity (12 μ V/V/mmHg and good in vitro stability when exposed to the continuous flow of saline solution (less than 0.05 mmHg/day drift after 50 h. During in vivo validation, the transducer has been successfully used to record the arterial pressure waveform of a female sheep. A small, intravascular sensor to continuously register the blood pressure at the inflow and the outflow of a VAD is developed and successfully validated in vivo.

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... The teddy bear denotes child-specific content. Related Articles and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos related to General Ultrasound Sponsored by ...

  20. Gamma probe and ultrasound guided fine needle aspiration cytology of the sentinel node (GULF) trial : Overview of the literature, pilot and study protocol

    NARCIS (Netherlands)

    C.M.C. Oude Ophuis (Charlotte); L.B. Koppert (Lisa); C. Monyé (Cécile); C.H.M. van Deurzen (Carolien); S. Koljenović (Senada); A.C.J. van Akkooi (Alexander); Verhoef, C.K. (Cornelis Kees); D.J. Grunhagen (Dirk Jan)

    2017-01-01

    markdownabstractBackground: Sentinel node (SN) biopsy (SNB) detects clinically occult metastases of breast cancer and melanoma in 20-30%. Wound infections, seroma and lymph edema occur in up to 10%. Targeted ultrasound (US) of the SN, (with fine needle aspiration cytology (FNAC) if appropriate) has

  1. Ultrasound versus fluoroscopy-guided caudal epidural steroid injection for the treatment of chronic low back pain with radiculopathy: A randomised, controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Arindam Kumar Hazra

    2016-01-01

    Full Text Available Background and Aims: Caudal epidural steroid administration is an effective treatment for chronic low back pain (LBP. Fluoroscopy guidance is the gold standard for pain procedures. Ultrasound guidance is recently being used in pain clinic procedures. We compared the fluoroscopy guidance and ultrasound guidance for caudal epidural steroid injection with respect to the time needed for correct placement of the needle and clinical effectiveness in patients with chronic LBP. Methods: Fifty patients with chronic LBP with radiculopathy, not responding to conventional medical management, were randomly allocated to receive injection depot methyl prednisolone (40 mg through caudal route either using ultrasound guidance (Group U, n = 25 or fluoroscopy guidance (Group F, n = 25. Pre-procedural visual analogue scale (VAS score and Oswestry Disability Index (ODI were noted. During the procedure, the time needed for correct placement of needle was observed. Adverse events, if any, were also noted. All patients were followed up for next 2 months to evaluate Visual Analogue Scale (VAS score and ODI at the 2nd week and again at the end of 1st and 2nd month. Results: The needle-placement time was less using ultrasound guidance as compared to fluoroscopy guidance (119 ± 7.66 vs. 222.28 ± 29.65 s, respectively,P< 0.001. Significant reduction in VAS score and ODI (clinical improvement was noted in the follow-up time points and comparable between the groups at all time points. Conclusion: Ultrasound guidance can be a safe alternative tool for achieving faster needle placement in caudal epidural space. Clinical effectiveness (reduction of VAS and ODI scores remains comparable between both the techniques.

  2. High definition ultrasound imaging for battlefield medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Kwok, K.S.; Morimoto, A.K.; Kozlowski, D.M.; Krumm, J.C.; Dickey, F.M. [Sandia National Labs., Albuquerque, NM (United States); Rogers, B; Walsh, N. [Texas Univ. Health Science Center, San Antonio, TX (United States)

    1996-06-23

    A team has developed an improved resolution ultrasound system for low cost diagnostics. This paper describes the development of an ultrasound based imaging system capable of generating 3D images showing surface and subsurface tissue and bone structures. We include results of a comparative study between images obtained from X-Ray Computed Tomography (CT) and ultrasound. We found that the quality of ultrasound images compares favorably with those from CT. Volumetric and surface data extracted from these images were within 7% of the range between ultrasound and CT scans. We also include images of porcine abdominal scans from two different sets of animal trials.

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ...

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page How is the procedure performed? For most ultrasound exams, you will be positioned lying face- ... Ultrasound examinations are painless and easily tolerated by most patients. Ultrasound exams in which the transducer is ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study may be part ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... at home and wear loose, comfortable clothing. You may be asked to wear a gown. What is ... into 3-D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ultrasound , ...

  9. Venous Ultrasound (Extremities)

    Science.gov (United States)

    ... waves from passing into your body. The sonographer (ultrasound technologist) or radiologist then places the transducer on the skin in various locations, sweeping over the area of interest or angling the ... ultrasound images are reviewed. This ultrasound examination is usually ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... be returned to the transducer for analysis. Ultrasound has difficulty penetrating bone and, therefore, can only see ...

  11. Ultrasound guided supraclavicular block.

    LENUS (Irish Health Repository)

    Hanumanthaiah, Deepak

    2013-09-01

    Ultrasound guided regional anaesthesia is becoming increasingly popular. The supraclavicular block has been transformed by ultrasound guidance into a potentially safe superficial block. We reviewed the techniques of performing supraclavicular block with special focus on ultrasound guidance.

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the body. Advancements in ultrasound technology include three-dimensional (3- ...

  14. Study protocol. IDUS - Instrumental delivery & ultrasound: a multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery.

    LENUS (Irish Health Repository)

    Murphy, Deirdre J

    2012-01-01

    Instrumental deliveries are commonly performed in the United Kingdom and Ireland, with rates of 12 - 17% in most centres. Knowing the exact position of the fetal head is a pre-requisite for safe instrumental delivery. Traditionally, diagnosis of the fetal head position is made on transvaginal digital examination by delineating the suture lines of the fetal skull and the fontanelles. However, the accuracy of transvaginal digital examination can be unreliable and varies between 20% and 75%. Failure to identify the correct fetal head position increases the likelihood of failed instrumental delivery with the additional morbidity of sequential use of instruments or second stage caesarean section. The use of ultrasound in determining the position of the fetal head has been explored but is not part of routine clinical practice.

  15. Enhancing ablation effects of a microbubble-enhancing contrast agent ("SonoVue") in the treatment of uterine fibroids with high-intensity focused ultrasound: a randomized controlled trial.

    Science.gov (United States)

    Jiang, Nan; Xie, Bin; Zhang, Xin; He, Min; Li, Kequan; Bai, Jin; Wang, Zhibiao; He, Jia; Zhang, Lian

    2014-10-01

    To evaluate the role of the ultrasound contrast agent SonoVue in enhancing the ablation effects of ultrasound-guided high-intensity focused ultrasound (HIFU) on uterine fibroids. Eighty patients with solitary uterine fibroids at a single center were randomly assigned to a control or SonoVue group. Of these, 40 were treated using HIFU alone; 40 who were pretreated with SonoVue received a bolus before the HIFU procedure. All patients underwent magnetic resonance imaging (MRI) scan before and after HIFU treatment. The post-HIFU MRI showed the nonperfused volume (NPV) in all of the treated uterine fibroids; the mean fractional ablation (NPV ratio) was 90.4 ± 8.3 % (range 66.4-100 %) in the SonoVue group and 82.8 ± 13.3 % (range 53.4-100 %) in the control group. The frequency of massive gray-scale changes that occurred during HIFU was greater in the group that received SonoVue than the group that did not. The average sonication time to reach massive gray-scale changes was significantly shorter in the group receiving SonoVue than the group without SonoVue. The acoustic energy for treating 1 mm(3) of uterine fibroid was less in the SonoVue group than the control group. No any major complication occurred in this study. Based on the results of this randomized controlled trial, SonoVue could be safely used to enhance the effects of HIFU treatment for uterine fibroids.

  16. Comparison of diagnostic yield and safety profile of radial endobronchial ultrasound-guided bronchoscopic lung biopsy with computed tomography-guided percutaneous needle biopsy in evaluation of peripheral pulmonary lesions: A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Ayush Gupta

    2018-01-01

    Full Text Available Background: Peripheral pulmonary lesions (PPLs pose a diagnostic challenge, and the optimal investigation in many such cases remains unclear. Computed tomography (CT-guided percutaneous needle biopsy (CT-PNB has been the modality of choice for such lesions with a high diagnostic accuracy but with high rates of pneumothorax. Endobronchial ultrasound (EBUS with a radial probe is an alternate diagnostic modality with increased diagnostic yield of bronchoscopy in the evaluation of PPL. We conducted a randomized controlled trial comparing the diagnostic accuracy and complication rates of radial EBUS with CT-guided lung biopsy for the evaluation of PPL. Methods: Fifty patients with PPL surrounded by lung parenchyma on all sides were randomly assigned to either radial EBUS or CT-PNB group (25 each. Results: Both groups had similar clinicoradiologic characteristics. The diagnostic accuracy of radial EBUS was comparable to CT-PNB with no statistically significant difference (72 vs. 84%; P = 0.306. However, the yield was significantly lower in right upper lobe lesions (20% vs. 83.3%; P = 0.03. CT-PNB group had significantly higher pneumothorax rates than radial EBUS (20% vs. 0%; P = 0.03. The lesions that were more than 2 cm, those with ultrasound feature of continuous hyperechoic margin around the lesion (P = 0.007, and the position of the ultrasound probe within the lesion (P < 0.001 were associated with a higher diagnostic yield with radial EBUS. Conclusion: Our findings suggest that radial EBUS is a safer investigation than CT-PNB with a comparable diagnostic accuracy for PPL not abutting the chest wall (CTRI/2017/02/007762.

  17. Nanoparticles for intravascular applications: physicochemical characterization and cytotoxicity testing.

    Science.gov (United States)

    Matuszak, Jasmin; Baumgartner, Jens; Zaloga, Jan; Juenet, Maya; da Silva, Acarília Eduardo; Franke, Danielle; Almer, Gunter; Texier, Isabelle; Faivre, Damien; Metselaar, Josbert M; Navarro, Fabrice P; Chauvierre, Cédric; Prassl, Ruth; Dézsi, László; Urbanics, Rudolf; Alexiou, Christoph; Mangge, Harald; Szebeni, János; Letourneur, Didier; Cicha, Iwona

    2016-03-01

    We report the physicochemical analysis of nanosystems intended for cardiovascular applications and their toxicological characterization in static and dynamic cell culture conditions. Size, polydispersity and ζ-potential were determined in 10 nanoparticle systems including liposomes, lipid nanoparticles, polymeric and iron oxide nanoparticles. Nanoparticle effects on primary human endothelial cell viability were monitored using real-time cell analysis and live-cell microscopy in static conditions, and in a flow model of arterial bifurcations. The majority of tested nanosystems were well tolerated by endothelial cells up to the concentration of 100 μg/ml in static, and up to 400 μg/ml in dynamic conditions. Pilot experiments in a pig model showed that intravenous administration of liposomal nanoparticles did not evoke the hypersensitivity reaction. These findings are of importance for future clinical use of nanosystems intended for intravascular applications.

  18. Design and implementation of an intravascular brachytherapy installation in cardiology

    International Nuclear Information System (INIS)

    Prieto, C.; Vano, E.; Fernandez, J.M.; Sabate, M.; Galvan, Y.C.

    2001-01-01

    Intravascular Brachytherapy (IVB) is a very promising technique for reducing restenosis rates. However, neither the exact absolute dose needed nor the optimal spatial and temporal distribution of dose inside the vessel wall for a successful treatment, nor the physical dosimetry of the various radioactive sources and devices for dose delivery, are well known. In this paper, an overview will be given of the design strategy, the dosimetric and radiation protection-related problems that we have met during the implementation of this technique at San Carlos hospital, adopted or foreseen solutions, and future research fields that we intend to carry out in order to reduce uncertainties and to achieve a deeper knowledge of the parameters that have an influence on the treatment. (author)

  19. Theoretical model of intravascular paramagnetic tracers effect on tissue relaxation

    DEFF Research Database (Denmark)

    Kjølby, Birgitte Fuglsang; Østergaard, Leif; Kiselev, Valerij G

    2006-01-01

    The concentration of MRI tracers cannot be measured directly by MRI and is commonly evaluated indirectly using their relaxation effect. This study develops a comprehensive theoretical model to describe the transverse relaxation in perfused tissue caused by intravascular tracers. The model takes...... into account a number of individual compartments. The signal dephasing is simulated in a semianalytical way by embedding Monte Carlo simulations in the framework of analytical theory. This approach yields a tool for fast, realistic simulation of the change in the transverse relaxation. The results indicate...... with bulk blood. The enhancement of relaxation in tissue is due to the contrast in magnetic susceptibility between blood vessels and parenchyma induced by the presence of paramagnetic tracer. Beyond the perfusion measurements, the results can be applied to quantitation of functional MRI and to vessel size...

  20. Evaluation of Disseminated Intravascular Coagulation in the Craniocerebral Traumas

    Directory of Open Access Journals (Sweden)

    Faruk Altinel

    2014-06-01

    Full Text Available Traumatic injury is one of the most important cause of disseminated intravascular coagulation (DIC. It occurs because of blood loss and hemodilution due to fluid resuscitation. The incidence of trauma associated DIC is mainly higher in the craniocerebral traumas. Even though craniocerebral trauma related DIC is well defined, the pathophysiology has been poorly characterized in the literature. Due to the fact that brain tissue is highly significant for procoagulant molecules, craniocerebral traumas are closely related to DIC. In the current study, 30 patients admitted to emergency room have been considered on the first and fifth day of admission to the hospital for the coagulation tests to evaluate DIC in both two groups. [Cukurova Med J 2014; 39(3.000: 488-495

  1. Scary gas: intravascular, intracranial, and intraspinal ectopic gas (part III).

    Science.gov (United States)

    Sandstrom, Claire K; Osman, Sherif F; Linnau, Ken F

    2017-08-01

    While ectopic gas can be a sign of dangerous disease requiring immediate medical or surgical intervention, it can also be an incidental and benign finding. Intravenous gas and spinal vacuum gas are common and almost always benign. Intravascular gas is most often related to instrumentation and, if intraarticular, can cause end-organ ischemia; however, treatment is usually supportive. Pneumocephalus arises from a communication with paranasal sinuses or mastoids more often than from meningeal infection and can usually be managed nonoperatively. In part 3 of this series, the different causes of ectopic gas in the vessels, skull, and spine are reviewed, as are the imaging features that can help to narrow the differential diagnosis.

  2. Mathematical Modeling of Intravascular Blood Coagulation under Wall Shear Stress

    Science.gov (United States)

    Rukhlenko, Oleksii S.; Dudchenko, Olga A.; Zlobina, Ksenia E.; Guria, Georgy Th.

    2015-01-01

    Increased shear stress such as observed at local stenosis may cause drastic changes in the permeability of the vessel wall to procoagulants and thus initiate intravascular blood coagulation. In this paper we suggest a mathematical model to investigate how shear stress-induced permeability influences the thrombogenic potential of atherosclerotic plaques. Numerical analysis of the model reveals the existence of two hydrodynamic thresholds for activation of blood coagulation in the system and unveils typical scenarios of thrombus formation. The dependence of blood coagulation development on the intensity of blood flow, as well as on geometrical parameters of atherosclerotic plaque is described. Relevant parametric diagrams are drawn. The results suggest a previously unrecognized role of relatively small plaques (resulting in less than 50% of the lumen area reduction) in atherothrombosis and have important implications for the existing stenting guidelines. PMID:26222505

  3. Robust intravascular optical coherence elastography by line correlations

    International Nuclear Information System (INIS)

    Soest, Gijs van; Mastik, Frits; Jong, Nico de; Steen, Anton F W van der

    2007-01-01

    We present a new method for intravascular optical coherence elastography, which is robust against motion artefacts. It employs the correlation between adjacent lines, instead of subsequent frames. Pressure to deform the tissue is applied synchronously with the line scan rate of the optical coherence tomography (OCT) instrument. The viability of the method is demonstrated with a simulation study. We find that the root mean square (rms) error of the displacement estimate is 0.55 μm, and the rms error of the strain is 0.6%. It is shown that high-strain spots in the vessel wall, such as observed at the sites of vulnerable atherosclerotic lesions, can be detected with the technique

  4. Vascular ultrasound.

    Science.gov (United States)

    Pilcher, D B; Ricci, M A

    1998-04-01

    Surgeon-interpreted diagnostic ultrasound has become the preferred screening test and often the definitive test for the diagnosis of arterial stenosis, aneurysm, and venous thrombosis. As a modality for surveillance, its noninvasive quality makes it particularly appealing as the test of choice to screen patients for abdominal aortic aneurysms or to perform follow-up examinations on those patients with a carotid endartectomy or in situ bypass grafts. The increasing reliance on intraoperative duplex imaging of vascular procedures demands that the surgeon learn the skills to perform the studies without a technologist or radiologist to interpret the examination.

  5. Therapeutic ultrasound treatment for excessive skin on the upper arms due to extensive weight loss after bariatric surgery: A single blind, randomised, controlled trial.

    Science.gov (United States)

    Bjerså, Kristofer; Biörserud, Christina; Fagevik Olsén, Monika

    2015-01-01

    Excessive skin is a side-effect of massive weight loss. The only evidence-based treatment for excessive skin is plastic surgery. Non-invasive treatments, therefore, need to be evaluated. The aim of this study was to investigate effects of therapeutic ultrasound treatment on excess skin on the upper arms after bariatric surgery. Fourteen patients were randomised to receive five treatments, each lasting for 30 minutes with active ultrasound treatment by CellsonicTM (Cellsonic Ltd) on one arm. The other arm served as control. The effect was evaluated objectively by measuring arm volume, circumference, and ptosis, and subjectively by a questionnaire where the patients assessed the effect of the treatment and amount and/or discomfort of the excess skin. No statistical differences were observed in the objectively measured variables. Some patients reported perceived effects and a majority reported positive experiences of the treatment. No side-effects were reported. This study could not find any objectively measured effect of ultrasound treatment on excessive skin after bariatric surgery. However, participants experienced relief of symptoms associated with excess skin, such as pain, looseness, and decreased skin burst, which indicates that ultrasonic treatment of patients with excessive skin should be further investigated.

  6. The effects of low-intensity pulsed ultrasound and pulsed electromagnetic fields bone growth stimulation in acute fractures: a systematic review and meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Hannemann, P F W; Mommers, E H H; Schots, J P M; Brink, P R G; Poeze, M

    2014-08-01

    The aim of this systematic review and meta-analysis was to evaluate the best currently available evidence from randomized controlled trials comparing pulsed electromagnetic fields (PEMF) or low-intensity pulsed ultrasound (LIPUS) bone growth stimulation with placebo for acute fractures. We performed a systematic literature search of the medical literature from 1980 to 2013 for randomized clinical trials concerning acute fractures in adults treated with PEMF or LIPUS. Two reviewers independently determined the strength of the included studies by assessing the risk of bias according to the criteria in the Cochrane Handbook for Systematic Reviews of Interventions. Seven hundred and thirty-seven patients from 13 trials were included. Pooled results from 13 trials reporting proportion of nonunion showed no significant difference between PEMF or LIPUS and control. With regard to time to radiological union, we found heterogeneous results that significantly favoured PEMF or LIPUS bone growth stimulation only in non-operatively treated fractures or fractures of the upper limb. Furthermore, we found significant results that suggest that the use of PEMF or LIPUS in acute diaphyseal fractures may accelerate the time to clinical union. Current evidence from randomized trials is insufficient to conclude a benefit of PEMF or LIPUS bone growth stimulation in reducing the incidence of nonunions when used for treatment in acute fractures. However, our systematic review and meta-analysis suggest that PEMF or LIPUS can be beneficial in the treatment of acute fractures regarding time to radiological and clinical union. PEMF and LIPUS significantly shorten time to radiological union for acute fractures undergoing non-operative treatment and acute fractures of the upper limb. Furthermore, PEMF or LIPUS bone growth stimulation accelerates the time to clinical union for acute diaphyseal fractures.

  7. Long-Term Results of a Phase II Trial of Ultrasound-Guided Radioactive Implantation of the Prostate for Definitive Management of Localized Adenocarcinoma of the Prostate (RTOG 98-05)

    International Nuclear Information System (INIS)

    Lawton, Colleen A.; Hunt, Daniel; Lee, W. Robert; Gomella, Leonard; Grignon, David; Gillin, Michael; Morton, Gerard; Pisansky, Thomas M.; Sandler, Howard

    2011-01-01

    Purpose: To evaluate the long-term effectiveness of transrectal ultrasound-guided permanent radioactive I 125 implantation of the prostate for organ confined adenocarcinoma of the prostate compared with historical data of prostatectomy and external beam radiotherapy within a cooperative group setting. Methods and Materials: Patients accrued to this study had histologically confirmed, locally confined adenocarcinoma of the prostate clinical stage T1b, T1c, or T2a; no nodal or metastatic disease; prostate-specific antigen level of ≤10 ng/ml; and a Gleason score of ≤6. All patients underwent transrectal ultrasound-guided radioactive I 125 seed implantation into the prostate. The prescribed dose was 145 Gy to the prostate planning target volume. Results: A total of 101 patients from 27 institutions were accrued to this protocol; by design, no single institution accrued more than 8 patients. There were 94 eligible patients. The median follow up was 8.1 years (range, 0.1-9.2 years). After 8 years, 8 patients had protocol-defined biochemical (prostate-specific antigen) failure (cumulative incidence, 8.0%); 5 patients had local failure (cumulative incidence, 5.5%); and 1 patient had distant failure (cumulative incidence, 1.1%; this patient also had biochemical failure and died of causes not related to prostate cancer). The 8-year overall survival rate was 88%. At last follow-up, no patient had died of prostate cancer or related toxicities. Three patients had maximum late toxicities of Grade 3, all of which were genitourinary. No Grade 4 or 5 toxicities were observed. Conclusions: The long-term results of this clinical trial have demonstrated that this kind of trial can be successfully completed through the RTOG and that results in terms of biochemical failure and toxicity compare very favorably with other brachytherapy published series as well as surgical and external beam radiotherapy series. In addition, the prospective, multicenter design highlights the probable

  8. Disseminated intravascular coagulation or acute coagulopathy of trauma shock early after trauma? A prospective observational study

    DEFF Research Database (Denmark)

    Johansson, Per Ingemar; Sorensen, Anne Marie; Perner, Anders

    2011-01-01

    ABSTRACT: INTRODUCTION: It is debated whether the early trauma induced coagulopathy (TIC) in severely injured patients reflects disseminated intravascular coagulation (DIC) with a fibrinolytic phenotype, acute coagulopathy of trauma shock (ACoTS) or yet other entities. This study investigated...

  9. Effect of catecholamines and insulin on plasma volume and intravascular mass of albumin in man

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J; Larsen, S

    1989-01-01

    1. The effect of intravenous catecholamine infusions and of intravenous insulin on plasma volume and intravascular mass of albumin was investigated in healthy males. 2. Physiological doses of adrenaline (0.5 microgram/min and 3 microgram/min) increased peripheral venous packed cell volume....../min, packed cell volume increased, plasma volume decreased and intravascular mass of albumin decreased significantly. During noradrenaline infusion at 6 micrograms/min, packed cell volume increased and plasma volume decreased, but intravascular mass of albumin did not change. 4. Application...... of a hyperinsulinaemic, euglycaemic glucose clamp led to an increase in transcapillary escape rate of albumin and a decrease in intravascular mass of albumin. Packed cell volume remained constant, while plasma volume, measured by radiolabelled albumin, decreased. 5. We conclude that the previously reported changes...

  10. Pilot randomized trial of therapeutic hypothermia with serial cranial ultrasound and 18-22 month follow-up for neonatal encephalopathy in a low resource hospital setting in uganda: study protocol

    Directory of Open Access Journals (Sweden)

    Costello Anthony

    2011-06-01

    Full Text Available Abstract Background There is now convincing evidence that in industrialized countries therapeutic hypothermia for perinatal asphyxial encephalopathy increases survival with normal neurological function. However, the greatest burden of perinatal asphyxia falls in low and mid-resource settings where it is unclear whether therapeutic hypothermia is safe and effective. Aims Under the UCL Uganda Women's Health Initiative, a pilot randomized controlled trial in infants with perinatal asphyxia was set up in the special care baby unit in Mulago Hospital, a large public hospital with ~20,000 births in Kampala, Uganda to determine: (i The feasibility of achieving consent, neurological assessment, randomization and whole body cooling to a core temperature 33-34°C using water bottles (ii The temperature profile of encephalopathic infants with standard care (iii The pattern, severity and evolution of brain tissue injury as seen on cranial ultrasound and relation with outcome (iv The feasibility of neurodevelopmental follow-up at 18-22 months of age Methods/Design Ethical approval was obtained from Makerere University and Mulago Hospital. All infants were in-born. Parental consent for entry into the trial was obtained. Thirty-six infants were randomized either to standard care plus cooling (target rectal temperature of 33-34°C for 72 hrs, started within 3 h of birth or standard care alone. All other aspects of management were the same. Cooling was performed using water bottles filled with tepid tap water (25°C. Rectal, axillary, ambient and surface water bottle temperatures were monitored continuously for the first 80 h. Encephalopathy scoring was performed on days 1-4, a structured, scorable neurological examination and head circumference were performed on days 7 and 17. Cranial ultrasound was performed on days 1, 3 and 7 and scored. Griffiths developmental quotient, head circumference, neurological examination and assessment of gross motor function were

  11. Gallium SPECT detection of neoplastic intravascular obstruction of the superior vena cava

    International Nuclear Information System (INIS)

    Swayne, L.C.; Kaplan, I.L.

    1989-01-01

    A rare case of an intravascular neoplastic obstruction of the superior vena cava is discussed. The lesion was detected with gallium single photon emission computed tomography (SPECT) despite a normal appearance on a concurrent radiographic CT study. A computer-generated composite SPECT-CT image confirmed the intravascular localization of the radioisotope, and a subsequent CT-guided transthoracic needle biopsy revealed a poorly differentiated adenocarcinoma

  12. [Cardiovascular depression and intravascular hemolysis secondary to ethanol injection for arteriovenous malformation].

    Science.gov (United States)

    Cai, Mei-Hua; Su, Li-Xin; Qiu, Lin

    2016-08-01

    Ethanol is the only liquid embolization agent which can cure arteriovenous malformation. Complications of ethanol embolization are not rare including local tissue injury, intravascular hemolysis and cardiovascular depression even collapse, etc. This report presented a case of long time cardiovascular depression and intravascular hemolysis secondary to ethanol embolotherapy of right ear. In order to avoid the fatal complications that are associated with ethanol sclerotherapy, anesthesiologists should consider the use of continuously invasive hemodynamic monitoring while surgeons should carefully choose the dose of ethanol.

  13. Ultrasound in Space Medicine

    Science.gov (United States)

    Dulchavsky, Scott A.; Sargsyan, A.E.

    2009-01-01

    This slide presentation reviews the use of ultrasound as a diagnostic tool in microgravity environments. The goals of research in ultrasound usage in space environments are: (1) Determine accuracy of ultrasound in novel clinical conditions. (2) Determine optimal training methodologies, (3) Determine microgravity associated changes and (4) Develop intuitive ultrasound catalog to enhance autonomous medical care. Also uses of Ultrasound technology in terrestrial applications are reviewed.

  14. Protection against high intravascular pressure in giraffe legs

    DEFF Research Database (Denmark)

    Petersen, Karin K; Hørlyck, Arne; Østergaard, Kristine Hovkjær

    2013-01-01

    The high blood pressure in giraffe leg arteries renders giraffes vulnerable to edema. We investigated in 11 giraffes whether large and small arteries in the legs and the tight fascia protect leg capillaries. Ultrasound imaging of foreleg arteries in anesthetized giraffes and ex vivo examination...

  15. MRI phenotypes of localized intravascular coagulopathy in venous malformations

    International Nuclear Information System (INIS)

    Koo, Kevin S.H.; Dowd, Christopher F.; Hess, Christopher P.; Mathes, Erin F.; Frieden, Ilona J.; Rosbe, Kristina W.; Hoffman, William Y.

    2015-01-01

    The incidence of localized intravascular coagulopathy (LIC) in venous malformations varies with lesion size and location, as well as the presence of palpable phleboliths. The development of LIC can cause pain and hemorrhage and can progress to disseminated intravascular coagulopathy (DIC) and thromboembolic disease resulting in death in some cases. Early recognition of LIC can relieve symptoms and prevent progression to life-threatening complications. The aim of this work was to identify MRI features of venous malformation associated with LIC. We hypothesized that venous malformations with larger capacitance, slower flow and less physiological compression (greater stasis) were more likely to be associated with LIC. In this HIPAA-compliant and IRB-approved study, we retrospectively reviewed clinical records and MRI for consecutive patients undergoing evaluation of venous malformations at our multidisciplinary Birthmarks and Vascular Anomalies Center between 2003 and 2013. Inclusion required consensus diagnosis of venous malformation and availability of laboratory data and MRI; patients on anticoagulation or those previously undergoing surgical or endovascular treatment were excluded. LIC was diagnosed when D-dimer exceeded 1,000 ng/mL and/or fibrinogen was less than 200 mg/dL. Two board-certified radiologists assessed the following MRI features for each lesion: morphology (spongiform vs. phlebectatic), presence of phleboliths, size, location (truncal vs. extremity), and tissue type(s) involved (subcutis, muscle, bone and viscera). Univariate logistic regression analyses were used to test associations between LIC and MRI findings, and stepwise regression was applied to assess the significance of the individual imaging predictors. Seventy patients, 37 with LIC, met inclusion criteria during the 10-year study period (age: 14.5 +/- 13.6 years [mean +/- standard deviation]; 30 male, 40 female). Both elevated D-dimer and low fibrinogen were associated with the presence of

  16. MRI phenotypes of localized intravascular coagulopathy in venous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Kevin S.H. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Dowd, Christopher F.; Hess, Christopher P. [University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Mathes, Erin F.; Frieden, Ilona J. [University of California, San Francisco, Department of Dermatology, San Francisco, CA (United States); Rosbe, Kristina W. [University of California, San Francisco, Department of Otolaryngology, San Francisco, CA (United States); Hoffman, William Y. [University of California, San Francisco, Department of Surgery, San Francisco, CA (United States)

    2015-10-15

    The incidence of localized intravascular coagulopathy (LIC) in venous malformations varies with lesion size and location, as well as the presence of palpable phleboliths. The development of LIC can cause pain and hemorrhage and can progress to disseminated intravascular coagulopathy (DIC) and thromboembolic disease resulting in death in some cases. Early recognition of LIC can relieve symptoms and prevent progression to life-threatening complications. The aim of this work was to identify MRI features of venous malformation associated with LIC. We hypothesized that venous malformations with larger capacitance, slower flow and less physiological compression (greater stasis) were more likely to be associated with LIC. In this HIPAA-compliant and IRB-approved study, we retrospectively reviewed clinical records and MRI for consecutive patients undergoing evaluation of venous malformations at our multidisciplinary Birthmarks and Vascular Anomalies Center between 2003 and 2013. Inclusion required consensus diagnosis of venous malformation and availability of laboratory data and MRI; patients on anticoagulation or those previously undergoing surgical or endovascular treatment were excluded. LIC was diagnosed when D-dimer exceeded 1,000 ng/mL and/or fibrinogen was less than 200 mg/dL. Two board-certified radiologists assessed the following MRI features for each lesion: morphology (spongiform vs. phlebectatic), presence of phleboliths, size, location (truncal vs. extremity), and tissue type(s) involved (subcutis, muscle, bone and viscera). Univariate logistic regression analyses were used to test associations between LIC and MRI findings, and stepwise regression was applied to assess the significance of the individual imaging predictors. Seventy patients, 37 with LIC, met inclusion criteria during the 10-year study period (age: 14.5 +/- 13.6 years [mean +/- standard deviation]; 30 male, 40 female). Both elevated D-dimer and low fibrinogen were associated with the presence of

  17. A Randomized Controlled Trial of Comparing Ultrasound-Guided Transversus Abdominis Plane Block with Local Anesthetic Infiltration in Peritoneal Dialysis Catheter Implantation.

    Science.gov (United States)

    Li, Qi; Tang, Xiaohong; Tao, Tian; Zhang, Wenjuan; Qin, Wei; Zhang, Jie; Li, Zi

    2017-11-22

    The ultrasound-guided transversus abdominis plane (TAP) block has been demonstrated as a useful analgesia technique in lower-abdomen surgeries. We hypothesized that it could be the principal anesthesia technique for end-stage renal disease (ESRD) patients undergoing peritoneal dialysis (PD) catheter (PDC) implantation using the open dissection method. This was a single-center, prospective, randomized, and double-blinded study. All eligible patients were randomized into 2 groups: the TAP block group (n = 20) and the local anesthetic infiltration (LAI) group (n = 20). Compared with the LAI group, the TAP block group revealed a remarkably lower visual analogue score, lower switching rate into general anesthesia, higher satisfaction rate, and less rescuing analgesic consumption during operation (p < 0.05). Both PD- and anesthesia-related complications were rare in the 4-week follow-up. The ultrasound-guided TAP block had better analgesic effect than LAI and can be used as a principal anesthesia technique for PDC implantation in ESRD patients without previous abdominal surgery. © 2017 S. Karger AG, Basel.

  18. Ultrasound-guided continuous femoral nerve block vs continuous fascia iliaca compartment block for hip replacement in the elderly: A randomized controlled clinical trial (CONSORT).

    Science.gov (United States)

    Yu, Bin; He, Miao; Cai, Guang-Yu; Zou, Tian-Xiao; Zhang, Na

    2016-10-01

    Continuous femoral nerve block and fascia iliaca compartment block are 2 traditional anesthesia methods in orthopedic surgeries, but it is controversial which method is better. The objective of this study was to compare the practicality, efficacy, and complications of the 2 modalities in hip replacement surgery in the elderly and to assess the utility of a novel cannula-over-needle set. In this prospective, randomized controlled clinical investigation, 60 elderly patients undergoing hip replacement were randomly assigned to receive either continuous femoral nerve block or continuous fascia iliaca compartment block. After ultrasound-guided nerve block, all patients received general anesthesia for surgery and postoperative analgesia through an indwelling cannula. Single-factor analysis of variance was used to compare the outcome variables between the 2 groups. There was a significant difference between the 2 groups in the mean visual analog scale scores (at rest) at 6 hours after surgery: 1.0 ± 1.3 in the femoral nerve block group vs 0.5 ± 0.8 in the fascia iliaca compartment block group (P fascia iliaca compartment block group had better analgesia on the lateral aspect of the thigh. There were no other significant differences between the groups. Both ultrasound-guided continuous femoral nerve block and fascia iliaca compartment block with the novel cannula-over-needle provide effective anesthesia and postoperative analgesia for elderly hip replacement patients.

  19. Effective low dosage of mepivacaine in ultrasound-guided axillary nerve block: a double-blinded, randomized clinical trial of efficacy in patients undergoing distal upper extremity surgery.

    Science.gov (United States)

    Perov, Samuel; Patel, Pranav; Kumar, Sanjeev; McKelvey, George M; Chidiac, Elie; Motlani, Faisal

    2014-05-01

    To evaluate two low-dose volumes (20 mL or 30 mL) of 1.5% mepivacaine solution used for ultrasound-guided axillary blockade for outpatients undergoing distal upper limb surgery. Prospective, double-blinded randomized study. Outpatient surgical setting of a university-affiliated hospital. 64 adult, ASA physical status 1, 2, and 3 patients, aged 28-46 years, scheduled for upper limb surgery. Patients were randomized to two groups to receive either 20 mL of 1.5% mepivacaine solution (n=31) or 30 mL of 1.5% mepivacaine solution (n=33) for ultrasound-guided axillary plexus blockade. Block duration, proportion of surgical and functional successful blocks, onset of sensory and motor blockade measured from 0 to 30 minutes following final needle extraction, total amount of preoperative sedative (midazolam), and intraoperative propofol administered were recorded. Following axillary plexus blockade, neither patient group showed any statistically significant difference in the percentage of functionally successful blockade (30 mL, 100%: 20 mL, 97%; P = 0.48), surgically successful blockade (30 mL, 100%; 20 mL, 94%; P = 0.23), cumulative sensory or motor blockade surgical time, block performance time, preoperative midazolam use, or intraoperative propofol use. Low volumes (30 mL or 20 mL) of 1.5% mepivacaine provides satisfactory anesthesia for ambulatory distal upper limb surgery with no significant difference in clinical outcomes. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Effectiveness of ultrasound treatment applied with exercise therapy on patients with ankylosing spondylitis: a double-blind, randomized, placebo-controlled trial.

    Science.gov (United States)

    Şilte Karamanlioğlu, Duygu; Aktas, Ilknur; Ozkan, Feyza Unlu; Kaysin, Meryem; Girgin, Nuray

    2016-05-01

    The aim of our study was to evaluate effectiveness of ultrasound treatment applied with exercise therapy in patients with ankylosing spondylitis. Fifty-two patients, who were diagnosed according to modified New York criteria, were aged 25-60, and have spine pain, were randomly assigned to two groups. Ultrasound (US) and exercise therapy were applied to treatment group (27); placebo US treatment and exercise therapy were applied to control group (25). Patients were evaluated before treatment, at the end of treatment, and 4 weeks after the treatment. Daily and night pain, morning stiffness, patient global assessment (PGA), doctor global assessment (DGA), Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), Bath Ankylosing Spondylitis Functional Index (BASFI), Bath Ankylosing Spondylitis Metrology Index (BASMI), Ankylosing Spondylitis Quality of Life (ASQoL) questionnaire, Ankylosing Spondylitis Disease Activity Score (ASDAS) erythrocyte sedimentation rate (ESR), and ASDAS C-reactive protein (CRP) were used as clinical parameters. In US group, all parameters showed significant improvements at 2 and 6 weeks, in comparison with the baseline. In placebo US group, significant improvement was obtained for all parameters (except tragus-to-wall distance and modified Schober test at 2 weeks and lumbar side flexion and modified Schober test at 6 weeks). Comparison of the groups showed significantly superior results of US group for parameters of BASMI (p treatment increases the effect of exercise in patients with ankylosing spondylitis.