WorldWideScience

Sample records for intravascular contrast agent

  1. Incompatibility of water soluble contrast media and intravascular pharmacologic agents: experimental study

    International Nuclear Information System (INIS)

    Lee, Ho Kyu; Kim, Seung Hyup; Kim, Sung Jin; Lee, Young Suk; Kim, Chu Wan; Han, Man Chung

    1991-01-01

    With the development of low osmolar and nonionic contrast media in clinical practice, radiologists have enjoyed increased clinical application along with other advantages such as improvement of patient comfort and safety. Recently, radiologists have introduced many intravascular pharmacologic agents to improve diagnostic quality and patient safety. Shortly after the introduction of these agents, however, it was observed that a precipitate results when a certain pharmacologic agent is mixed with a low osmolar contrast media. These observations have prompted testing of several other drugs used for incompatibility with contrast media. To verify these reports and to investigate other medications not previously tested, the authors analyzed mixtures of contrast agents and medications in vitro and observed them for visible precipitates after operating the high-speed centrifuge. The results were as fallows: The contrast media that produced incompatibilities with some pharmacologic agents were ioxaglate, diatrizote, and iothalamate in the order of frequency. The contrast media that produced no precipitate were iopromide and ioxithalamate. The pharmacologic agents that produced precipitate with some contrast media were Papaverine, Benadryl, Protamine, Cimetidine, Regitin, and Gentamicin. Therefore, we recommend that caution should be taken to recognize incompatibilities and avoid them when intravascular pharmacologic agents of any kind may be incompatible

  2. Clinical application of intravascular administration of non-ionic, low osmolar contrast agent, Ioversol (Optiray 320) and its side effects comparison with Meglumine Iothalamate (Conray 60)

    International Nuclear Information System (INIS)

    Hong, Hyun Sook; Kim, Dae Ho; Lee, Hae Kyung; Chung, Moo Chan; Choi, Deuk Lin; Kwon, Kuy Hyang; Kim, Ki Jung

    1990-01-01

    Ioversol, the non-ionic, low osmolar contrast agent has been well characterized chemically and in terms of basic toxicity testing. Ioversol has a fomula similar to that of other nonionic agent. We review the results of intravascular use of this contrast agent, compared ionic contrast media(Meglumine Iothalamate (Conray 60)). Each study was assessed for imaging quality,and patients were monitored vital signs, changes of hematology and blood chemistry and urinalysis before and after contrast administration and were observed for occurrence of side effects. A small number of side effects were reported but no clinically significant sequelae in Ioversol group and much less vital sign changes compared with Conray group. There were no significant changes in vital signs related to the use of Ioversol, and no significant alterations in the renal function parameter or other blood chemistry and hematology measurement were encountered in both contrast media. In most cases, the image qualities were good. In conclusion, Ioversol is safe, well tolerated and efficious for use in intravascular contrast agent, and less vital sign changes and side effect than ionic Meglumine Iothalamte, and Ioversol is likely to provide a useful and acceptable alternative to other low osmolar and nonionic contrast agents

  3. Development of a conjugated gadolinium and cisplatin-gelatin possessing properties as an intravascular contrast agent for MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sonoda, Akinaga [Department of Radiology, Shiga University of Medical Science, Setatsukinowa-cho, Otsu, Shiga 520-2192 (Japan)], E-mail: akinagasonoda@yahoo.co.jp; Nitta, Norihisa [Department of Radiology, Shiga University of Medical Science, Setatsukinowa-cho, Otsu, Shiga 520-2192 (Japan)], E-mail: r34nitta@yahoo.co.jp; Ohta, Shinichi [Department of Radiology, Shiga University of Medical Science, Setatsukinowa-cho, Otsu, Shiga 520-2192 (Japan)], E-mail: junryuhei@belle.shiga-med.ac.jp; Seko, Ayumi [Department of Radiology, Shiga University of Medical Science, Setatsukinowa-cho, Otsu, Shiga 520-2192 (Japan)], E-mail: sekoayumi@yahoo.co.jp; Jo, Jun-ichiro [Department of Biomaterials, Institute for Frontier Medical Sciences, Kyoto University, 53 Kawara-cho Shogoin, Sakyo-ku, Kyoto 606-8501 (Japan)], E-mail: jo@frontier.kyoto-u.ac.jp; Morikawa, Shigehiro [Biomedical MR Science Research Center, Shiga University of Medical Science, Setatsukinowa-cho, Otsu, Shiga 520-2192 (Japan)], E-mail: morikawa@belle.shiga-med.ac.jp; Tabata, Yasuhiko [Department of Biomaterials, Institute for Frontier Medical Sciences, Kyoto University, 53 Kawara-cho Shogoin, Sakyo-ku, Kyoto 606-8501 (Japan)], E-mail: yasuhiko@frontier.kyoto-u.ac.jp; Takahashi, Masashi [Department of Radiology, Shiga University of Medical Science, Setatsukinowa-cho, Otsu, Shiga 520-2192 (Japan)], E-mail: masashi@belle.shiga-med.ac.jp; Murata, Kiyoshi [Department of Radiology, Shiga University of Medical Science, Setatsukinowa-cho, Otsu, Shiga 520-2192 (Japan)], E-mail: murata@belle.shiga-med.ac.jp

    2009-09-15

    Purpose: The purpose of this study is to create a Gd-DTPA-Gel-Cis compound, which made from gadolinum (Gd), diethylenetriaminepentaacetic acid (DTPA)-dianhydride, cis-diamminedichloroplatinum (Cis) and bovine gelatin (Gel), that makes it possible to visualize Cis as intravascular agent under magnetic resonance imaging (MRI). Materials and methods: The amount of DTPA, Gd, and Cis were titrated to determine the new compound's conjugation ratio with gelatin. Considering these functions, Gd-DTPA-Gel-Cis was synthesized, and its stability in bovine serum was evaluated. In addition, the signal intensity of the diluted sample was measured under 1.5 Tesla MRI. Results: The synthesized 10 mg/ml of Gd-DTPA-Gel-Cis contained 42.84 {mu}g/ml of Gd and 1.53 {mu}g/ml of platinum. Gd-DTPA-Gel-Cis (100 mg/10 ml) enclosed into the cellulose dialysis tubing was placed in 90 ml of bovine serum and shaken reciprocally at 72 stroke/min at 37 deg. C. Partial release of free Pt was shown at 6 and 24 h, but no release of Gd occurred for a 24-h period. And high stability of Gd conjugated to DTPA-Gel-Cis. This result suggests possible anti-tumor effectiveness and high stability of Gd conjugated to DTPA-Gel-Cis. The diluted sample presented high signal intensity under 1.5 Tesla MRI. Conclusion: Gd-DTPA-Gel-Cis has been developed successfully and we have proven its stability and contrast ability in MRI.

  4. Histamine release and endothelial leakage from an intravascular contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Raininko, R.

    1981-04-01

    The endothelial injury produced by meglumine iodamide was studied in the rat aorta. A mixture of blood and contrast medium was more toxic to the endothelium than the pure contrast agent. This difference disappeared after premedication with antihistamine, which did not affect the injury produced by the pure contrast agent. Meglumine iodamide appears to cause a release of histamine from blood but not from the aortic endothelium nor from surrounding tissues in amounts demonstrable by this method. Leucocytes are a source of histamine after intravascular contrast medium administration.

  5. Death following intravascular administration of contrast media

    International Nuclear Information System (INIS)

    Shehadi, W.H.

    1985-01-01

    Adverse reactions to intravascularly administered contrast media preceding death and the autopsy findings in 44 patients are presented. There is a wide scatter of the age distribution of fatal reactions. The highest incidence is in the 50-70 year age group. Similar observations were obtained from the 405 deaths due to contrast media reported to the Food and Drug Administration of the United States. In the same age group the number of reactions is highest, likewise the autopsy findings. The predominant autopsy findings are pulmonary edema, congestion and hemorrhage; arteriosclerosis, both general and coronary. In the younger age group the autopsy findings are limited mostly to the respiratory tract. Fatal reactions to contrast media occur often without warning and most deaths occur within 15 min to 6 hours. Reactions to contrast media occur without relation to sex or age. (orig.)

  6. Role of informed consent for intravascular contrast media

    International Nuclear Information System (INIS)

    Hopper, K.D.; Tyler, H.N. Jr.

    1988-01-01

    To evaluate the usefulness of different degrees of informed consent for intravascular contrast media, the authors divided 100 patients into four groups: (1) informed consent with no information on intravascular contrast media, (2) simple written informed consent that detailed common risks, (3) detailed written informed consent that detailed all known risks, and (4) MD informed consent, during which a radiologist discussed all known risks of intravascular contrast media. Physician counseling time for group 4 averaged 11.4 minutes. On a postprocedure test about the common complications and risk factors of intravascular contrast media, the average scores were: group 1, 38.4%; group 2, 68.2%; group 3, 63.2%; and group 4, 69.8%. There was no statistical difference between groups 2-4 on the postprocedure test. If informed consent is to be used prior to intravascular contrast media administration, a simple written consent detailing the common risks and risk factors appears to be the best method

  7. Adverse reactions to intravascularly administered contrast media

    International Nuclear Information System (INIS)

    Olin, T.

    1986-01-01

    A hypothesis is formulated about the mechanisms causing adverse reactions to contrast media. Contrast media act in two ways. They stimulate the mast cells to release histamine and leukotrienes, and they inhibit the enzymes which otherwise degrade leukotrienes. Thus individuals, especially those with a history of allergy, are easily exposed to undue amounts of leukotrienes and these are responsible for the adverse reactions. (orig.)

  8. Late adverse reactions to intravascular iodinated contrast media

    International Nuclear Information System (INIS)

    Webb, Judith A.W.; Stacul, Fulvio; Thomsen, Henrik S.; Morcos, Sameh K.

    2003-01-01

    Late adverse reactions to intravascular iodinated contrast media are defined as reactions occurring 1 h to 1 week after contrast medium injection. They have received increasing interest over the past decade, but their prevalence remains uncertain and their pathophysiology is not fully understood. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and to issue guidelines. An extensive literature search was carried out and summarized in a report. Based on the available information, simple guidelines have been drawn up. The report and guidelines were discussed at the 8th European Symposium on Urogenital Radiology in Genoa. Late adverse reactions after intravascular iodinated contrast medium include symptoms such as nausea, vomiting, headache, itching, skin rash, musculoskeletal pain, and fever. A significant proportion of these reactions is unrelated to the contrast medium; however, allergy-like skin reactions are well-documented side effects of contrast media with an incidence of approximately 2%. Late reactions appear to be commoner after non-ionic dimers. The majority of late skin reactions after contrast medium exposure are probably T-cell-mediated allergic reactions. Patients at increased risk of late skin reactions are those with a history of previous contrast medium reaction and those on interleukin-2 treatment. Most skin reactions are self-limiting and resolve within a week. Management is symptomatic and similar to the management of other drug-induced skin reactions. (orig.)

  9. New MR contrast agent

    International Nuclear Information System (INIS)

    Grossman, C.D.; Subramanian, G.; Schneider, R.; Szeverenyi, N.E.; Rosenbaum, A.M.; Gagne, G.; Tillapaugh-Fay, G.; Berlin, R.; Ritter-Hrncirik, C.; Yu, S.

    1990-01-01

    This paper evaluates an MR contrast agent-meglumine tris-(2,6-dicarboxypyridine) gadolinium (III) or gadolinium dipicolinate (Gd-DPC)-produced in-house. Rats were anesthetized with pentobarbital. For renal imaging, bowel motion artifact was minimized with glucagon (0.014 mg/kg, intravenous (IV)). Enhanced images were generated on a 2-T chemical shift imaging system with a 31-cm horizontal bore magnet after IV injection of Gd-DPC (100 μM/kg). Coronal sections of the kidneys and sagittal sections of the brain, 2 mm thick, were made. Six to eight excitations and 128 or 356 phase-encoding steps were used for each image. Control animals were injected with equivalent doses of gadopentetate dimeglumine

  10. Tissue-specific MR contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Weinmann, Hanns-Joachim E-mail: hannsjoachim.weinmann@schering.de; Ebert, Wolfgang; Misselwitz, Bernd; Schmitt-Willich, Heribert

    2003-04-01

    The purpose of this review is to outline recent trends in contrast agent development for magnetic resonance imaging. Up to now, small molecular weight gadolinium chelates are the workhorse in contrast enhanced MRI. These first generation MR contrast agents distribute into the intravascular and interstitial space, thus allowing the evaluation of physiological parameters, such as the status or existence of the blood-brain-barrier or the renal function. Shortly after the first clinical use of paramagnetic metallochelates in 1983, compounds were suggested for liver imaging and enhancing a cardiac infarct. Meanwhile, liver specific contrast agents based on gadolinium, manganese or iron become reality. Dedicated blood pool agents will be available within the next years. These gadolinium or iron agents will be beneficial for longer lasting MRA procedures, such as cardiac imaging. Contrast enhanced lymphography after interstitial or intravenous injection will be another major step forward in diagnostic imaging. Metastatic involvement will be seen either after the injection of ultrasmall superparamagnetic iron oxides or dedicated gadolinium chelates. The accumulation of both compound classes is triggered by an uptake into macrophages. It is likely that similar agents will augment MRI of atheriosclerotic plaques, a systemic inflammatory disease of the arterial wall. Thrombus-specific agents based on small gadolinium labeled peptides are on the horizon. It is very obvious that the future of cardiovascular MRI will benefit from the development of new paramagnetic and superparamagnetic substances. The expectations for new tumor-, pathology- or receptor-specific agents are high. However, is not likely that such a compound will be available for daily routine MRI within the next decade.

  11. Neuroimaging: do we really need new contrast agents for MRI?

    International Nuclear Information System (INIS)

    Roberts, T.P.L.; Chuang, N.; Roberts, H.C.

    2000-01-01

    The use of exogenous contrast media in magnetic resonance imaging of the brain has brought dramatic improvement in the sensitivity of detection and delineation of pathological structures, such as primary and metastatic brain tumors, inflammation and ischemia. Disruption of the blood brain barrier leads to accumulation of the intravenously injected contrast material in the extravascular space, leading to signal enhancement. Magnetic resonance angiography benefits from T 1 -shortening effects of contrast agent, improving small vessel depiction and providing vascular visualization even in situations of slow flow. High speed dynamic MRI after bolus injection of contrast media allows tracer kinetic modeling of cerebral perfusion. Progressive enhancement over serial post-contrast imaging allows modeling of vascular permeability and thus quantitative estimation of the severity of blood brain barrier disruption. With such an array of capabilities and ever improving technical abilities, it seems that the role of contrast agents in MR neuroimaging is established and the development of new agents may be superfluous. However, new agents are being developed with prolonged intravascular residence times, and with in-vivo binding of ever-increasing specificity. Intravascular, or blood pool, agents are likely to benefit magnetic resonance angiography of the carotid and cerebral vessels; future agents may allow the visualization of therapeutic drug delivery, the monitoring of, for example, gene expression, and the imaging evaluation of treatment efficacy. So while there is a substantial body of work that can be performed with currently available contrast agents, especially in conjunction with optimized image acquisition strategies, post processing, and mathematical analysis, there are still unrealized opportunities for novel contrast agent introduction, particularly those exploiting biological specificity. This article reviews the current use of contrast media in magnetic resonance

  12. Nuclear magnetic resonance contrast agents

    Science.gov (United States)

    Smith, P.H.; Brainard, J.R.; Jarvinen, G.D.; Ryan, R.R.

    1997-12-30

    A family of contrast agents for use in magnetic resonance imaging and a method of enhancing the contrast of magnetic resonance images of an object by incorporating a contrast agent of this invention into the object prior to forming the images or during formation of the images. A contrast agent of this invention is a paramagnetic lanthanide hexaazamacrocyclic molecule, where a basic example has the formula LnC{sub 16}H{sub 14}N{sub 6}. Important applications of the invention are in medical diagnosis, treatment, and research, where images of portions of a human body are formed by means of magnetic resonance techniques. 10 figs.

  13. Late adverse reactions to intravascular iodine based contrast media

    DEFF Research Database (Denmark)

    Bellin, Marie-France; Stacul, Fulvio; Webb, Judith A W

    2011-01-01

    DEFINITION: Late adverse reactions (LAR) to contrast media (CM) are defined as reactions occurring 1 h to 1 week after exposure. NEED FOR REVIEW: In view of more prospective studies of LAR and new data about their pathophysiology, the Contrast Medium Safety Committee (CMSC) of the European Societ...

  14. Late adverse reactions to intravascular iodine based contrast media

    DEFF Research Database (Denmark)

    Bellin, Marie-France; Stacul, Fulvio; Webb, Judith A W

    2011-01-01

    DEFINITION: Late adverse reactions (LAR) to contrast media (CM) are defined as reactions occurring 1 h to 1 week after exposure. NEED FOR REVIEW: In view of more prospective studies of LAR and new data about their pathophysiology, the Contrast Medium Safety Committee (CMSC) of the European Society...... or delayed reading intradermal). The main risk factors for LAR are a previous reaction to contrast medium, a history of allergy, and interleukin-2 treatment. Most skin reactions are mild or moderate and self-limiting. MANAGEMENT: Management is symptomatic and similar to the management of other drug...

  15. Late adverse reactions to intravascular iodine based contrast media

    DEFF Research Database (Denmark)

    Bellin, Marie-France; Stacul, Fulvio; Webb, Judith A W

    2011-01-01

    DEFINITION: Late adverse reactions (LAR) to contrast media (CM) are defined as reactions occurring 1 h to 1 week after exposure. NEED FOR REVIEW: In view of more prospective studies of LAR and new data about their pathophysiology, the Contrast Medium Safety Committee (CMSC) of the European Society...... of Urogenital Radiology (ESUR) reviewed the literature on LAR and updated their guidelines. CLINICAL FEATURES AND PATHOLOGY: LAR after CM include symptoms such as nausea, vomiting, headache, itching, skin rash, musculoskeletal pain, and fever. Skin reactions are well-documented LAR to CM with an incidence...... of approximately 2%-4% after nonionic monomers. LAR are commoner by a factor of three to four after nonionic dimers. The commonest skin reactions are maculopapular rashes, erythema and skin swelling. These reactions are T cell-mediated immune reactions, and the diagnosis may be confirmed using skin tests (patch...

  16. Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents

    Czech Academy of Sciences Publication Activity Database

    Harabis, V.; Kolář, R.; Mézl, M.; Jiřík, Radovan

    2013-01-01

    Roč. 34, č. 2 (2013), s. 151-162 ISSN 0967-3334 R&D Projects: GA ČR GAP102/12/2380 Institutional support: RVO:68081731 Keywords : perfusion model * ultrasound * contrast agent * intravascular perfusion * tissue phantom Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 1.617, year: 2013

  17. The cerebral intravascular enhancement sign is not specific: a contrast-enhanced MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Bakshi, R.; Kinkel, W.R.; Bates, V.E.; Mechtler, L.L.; Kinkel, P.R. [Lucy Dent Imaging Center, University at Buffalo, NY (United States)

    1999-02-01

    The intravascular enhancement (IVE) sign, also known as the ``arterial enhancement sign``, is an abnormal finding in the brain on contrast-enhanced MRI studies. IVE has been described in arterial cerebrovascular disorders, most commonly in acute or subacute arterial ischemic infarcts. However, the specificity of this sign has not been established. We describe four patients with disorders other than arterial strokes in whom gadolinium-enhanced high-field (1.5 T) MRI suggested IVE. The conditions were herpes simplex viral encephalitis, idiopathic cerebellitis, pneumococcal meningitis, and superior sagittal sinus thrombosis with venous infarction. IVE in these cases may be due to multiple factors, including arterial, venous, perivascular, and leptomeningeal or sulcal contrast medium accumulation. Our observations suggest that arterial ischemia, previously described as the cardinal cause of IVE, probably does not explain all instances, and urge caution in interpreting this sign as a specific MRI manifestation of acute arterial infarction or ischemia. (orig.) With 4 figs., 1 tab., 44 refs.

  18. The study of cardiovascular changes by intravascular injection of contrast media

    International Nuclear Information System (INIS)

    Kim, Yang Sook; Park, Chang Yoon

    1986-01-01

    This investigation was aimed to study the effect of contrast media on the cardiovascular system. So in this study, pithed rats were used whether alteration in cardiovascular system by contrast media were controlled centrally. Furthermore, several hypertonic solutions were also used to clarify the effect of contrast media. The results are as follows: 1. Intravenous injection of contrast media in rats (2.5 ml/kg) caused hypotension and bradycardia. The effects were neither blocked by pretreatment of atropine nor pyribenzamine+atropine. 2. NaCI 4.7%, dextrose 24.8%, urea 9.0% and glycerol 10.1% (v/v) which were equiosmolar with contrast media, caused hypotension, but did not affect the heart rate. 3. In pithed rats, intravenous injection of Angiografin increased blood pressure in a dose-dependant manner, and caused decrease in heart rate compared with those of control rats. 4. In pithed rats, bradycardia by intravascular injection with Angiografin was partially blocked by atropine. 5. Metrizamide of which iodine content was adjusted to 280 mg/ml caused increased in blood pressure when was injected intravenously in pithed rats with little effect on heart rate. 6. When perfused with contrast media in rat hindlimb at 15 ml/min./kg speed both perfusion pressure and flow effluent increased, simultaneously. These results suggest that hypotension might be caused by the central effect due to hyperosmolarity of contrast media and bradycardia caused by both parasympathetic stimulation and direct inhibitory action on the cardiac conductive system.

  19. Ultrasound contrast agents: An overview

    International Nuclear Information System (INIS)

    Cosgrove, David

    2006-01-01

    With the introduction of microbubble contrast agents, diagnostic ultrasound has entered a new era that allows the dynamic detection of tissue flow of both the macro and microvasculature. Underpinning this development is the fact that gases are compressible, and thus the microbubbles expand and contract in the alternating pressure waves of the ultrasound beam, while tissue is almost incompressible. Special software using multiple pulse sequences separates these signals from those of tissue and displays them as an overlay or on a split screen. This can be done at low acoustic pressures (MI < 0.3) so that the microbubbles are not destroyed and scanning can continue in real time. The clinical roles of contrast enhanced ultrasound scanning are expanding rapidly. They are established in echocardiography to improve endocardial border detection and are being developed for myocardial perfusion. In radiology, the most important application is the liver, especially for focal disease. The approach parallels that of dynamic CT or MRI but ultrasound has the advantages of high spatial and temporal resolution. Thus, small lesions that can be indeterminate on CT can often be studied with ultrasound, and situations where the flow is very rapid (e.g., focal nodular hyperplasia where the first few seconds of arterial perfusion may be critical to making the diagnosis) are readily studied. Microbubbles linger in the extensive sinusoidal space of normal liver for several minutes whereas they wash out rapidly from metastases, which have a low vascular volume and thus appear as filling defects. The method has been shown to be as sensitive as three-phase CT. Microbubbles have clinical uses in many other applications where knowledge of the microcirculation is important (the macrocirculation can usually be assessed adequately using conventional Doppler though there are a few important situations where the signal boost given by microbubbles is useful, e.g., transcranial Doppler for evaluating

  20. Ultrasound contrast agents: an overview.

    Science.gov (United States)

    Cosgrove, David

    2006-12-01

    With the introduction of microbubble contrast agents, diagnostic ultrasound has entered a new era that allows the dynamic detection of tissue flow of both the macro and microvasculature. Underpinning this development is the fact that gases are compressible, and thus the microbubbles expand and contract in the alternating pressure waves of the ultrasound beam, while tissue is almost incompressible. Special software using multiple pulse sequences separates these signals from those of tissue and displays them as an overlay or on a split screen. This can be done at low acoustic pressures (MI<0.3) so that the microbubbles are not destroyed and scanning can continue in real time. The clinical roles of contrast enhanced ultrasound scanning are expanding rapidly. They are established in echocardiography to improve endocardial border detection and are being developed for myocardial perfusion. In radiology, the most important application is the liver, especially for focal disease. The approach parallels that of dynamic CT or MRI but ultrasound has the advantages of high spatial and temporal resolution. Thus, small lesions that can be indeterminate on CT can often be studied with ultrasound, and situations where the flow is very rapid (e.g., focal nodular hyperplasia where the first few seconds of arterial perfusion may be critical to making the diagnosis) are readily studied. Microbubbles linger in the extensive sinusoidal space of normal liver for several minutes whereas they wash out rapidly from metastases, which have a low vascular volume and thus appear as filling defects. The method has been shown to be as sensitive as three-phase CT. Microbubbles have clinical uses in many other applications where knowledge of the microcirculation is important (the macrocirculation can usually be assessed adequately using conventional Doppler though there are a few important situations where the signal boost given by microbubbles is useful, e.g., transcranial Doppler for evaluating

  1. Intravascular enhancement with identical iodine delivery rate using different iodine contrast media in a circulation phantom.

    Science.gov (United States)

    Mihl, Casper; Wildberger, Joachim E; Jurencak, Tomas; Yanniello, Michael J; Nijssen, Estelle C; Kalafut, John F; Nalbantov, Georgi; Mühlenbruch, Georg; Behrendt, Florian F; Das, Marco

    2013-11-01

    Both iodine delivery rate (IDR) and iodine concentration are decisive factors for vascular enhancement in computed tomographic angiography. It is unclear, however, whether the use of high-iodine concentration contrast media is beneficial to lower iodine concentrations when IDR is kept identical. This study evaluates the effect of using different iodine concentrations on intravascular attenuation in a circulation phantom while maintaining a constant IDR. A circulation phantom with a low-pressure venous compartment and a high-pressure arterial compartment simulating physiological circulation parameters was used (heart rate, 60 beats per minute; stroke volume, 60 mL; blood pressure, 120/80 mm Hg). Maintaining a constant IDR (2.0 g/s) and a constant total iodine load (20 g), prewarmed (37°C) contrast media with differing iodine concentrations (240-400 mg/mL) were injected into the phantom using a double-headed power injector. Serial computed tomographic scans at the level of the ascending aorta (AA), the descending aorta (DA), and the left main coronary artery (LM) were obtained. Total amount of contrast volume (milliliters), iodine delivery (grams of iodine), peak flow rate (milliliter per second), and intravascular pressure (pounds per square inch) were monitored using a dedicated data acquisition program. Attenuation values in the AA, the DA, and the LM were constantly measured (Hounsfield unit [HU]). In addition, time-enhancement curves, aortic peak enhancement, and time to peak were determined. All contrast injection protocols resulted in similar attenuation values: the AA (516 [11] to 531 [37] HU), the DA (514 [17] to 531 [32] HU), and the LM (490 [10] to 507 [17] HU). No significant differences were found between the AA, the DA, and the LM for either peak enhancement (all P > 0.05) or mean time to peak (AA, 19.4 [0.58] to 20.1 [1.05] seconds; DA, 21.1 [1.0] to 21.4 [1.15] seconds; LM, 19.8 [0.58] to 20.1 [1.05] seconds). This phantom study demonstrates that

  2. BODIPY derivatives as molecular photoacoustic contrast agents

    Science.gov (United States)

    Laoui, Samir; Bag, Seema; Dantiste, Olivier; Frenette, Mathieu; Hatamimoslehabadi, Maryam; Bellinger-Buckley, Stephanie; Tseng, Jen-Chieh; Rochford, Jonathan; Yelleswarapu, Chandra

    2014-03-01

    Photoacoustic imaging (PAI) is emerging as a key in vivo imaging technique. Endogenous contrast agents alone are insufficient to obtain high contrast images necessitating a need for synthetic exogenous contrast agents. In recent years a great deal of research has been devoted to the development of nanoparticle based contrast agents with little effort on molecular systems. Here we report on the design and evaluation of BODIPY inspired molecular photoacoustic contrast agents (MPACs). Through chemical modification of the established BODIPY fluorophore, increasing its vibrational freedom and appending with non-emissive functionalities, it is demonstrated that the S0-S1 absorbed excitation energy is redirected towards a nonradiative excited-state decay pathway. Optical and photoacoustic characterization of the modified BODIPY MPACs demonstrates a stronger photoacoustic signal compared to the corresponding fluorescent BODIPY probes.

  3. Contrast Agent in Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Vu-Quang, Hieu

    2015-01-01

    Nanoparticles have been employed as contrast agent in magnetic resonance imaging (MRI) in order to improve sensitivity and accuracy in diagnosis. In addition, these contrast agents are potentially combined with other therapeutic compounds or near infrared bio-imaging (NIR) fluorophores to obtain...... theranostic or dual imaging purposes, respectively. There were two main types of MRI contrast agent that were synthesized during this PhD project including fluorine containing nanoparticles and magnetic nanoparticles. In regard of fluorine containing nanoparticles, there were two types contrast agent...... that were synthesized in project I and II. In project I, Poly (lactic-co-glycolic acid)-block-poly (ethylene glycol)-Folate Pefluorooctyl Bromide/Indocyanine green/ Doxorubicin (PLGA-PEG-Folate PFOB/ICG/Dox) has been formulated for the dual imaging NIR and 19F MRI as well as in the combination of Dox...

  4. Contrast agent choice for intravenous coronary angiography

    International Nuclear Information System (INIS)

    Zeman, H.D.; Siddons, D.P.

    1989-01-01

    The screening of the general population for coronary artery disease would be practical if a method existed for visualizing the extent of occlusion after an intravenous injection of contrast agent. Measurements performed with monochromatic synchrotron radiation x-rays and an iodine containing contrast agent at the Stanford Synchrotron Radiation Laboratory have shown that such an intravenous angiography procedure would be possible with an adequately intense monochromatic x-ray source. Because of the size and cost of synchrotron radiation facilities it would be desirable to make the most efficient use of the intensity available, while reducing as much as possible the radiation dose experienced by the patient. By choosing contrast agents containing elements with a higher atomic number than iodine, it is possible to both improve the image quality and reduce the patient radiation dose, while using the same synchrotron source. By using Si monochromator crystals with a small mosaic spread, it is possible to increase the x-ray flux available for imaging by over an order of magnitude, without any changes in the storage ring or wiggler magnet. The most critical imaging task for intravenous coronary angiography utilizing synchrotron radiation x-rays is visualizing a coronary artery through the left ventricle or aorta which also contains a contrast agent. Calculations have been made of the signal to noise ratio expected for this imaging task for various contrast agents with atomic numbers between that of iodine and bismuth

  5. Process for preparation of MR contrast agents

    DEFF Research Database (Denmark)

    2002-01-01

    The present invention provides a process for the preparation of an MR contrast agent, said process comprising: i) obtaining a solution in a solvent of a hydrogenatable, unsaturated substrate compound and a catalyst for the hydrogenation of said substrate compound; ii) introducing said solution...... in droplet form into a chamber containing hydrogen gas (H2) enriched in para-hydrogen (p-1H2) and/or ortho-deuterium (o-2H2) whereby to hydrogenate said substrate to form a hydrogenated imaging agent; iii) optionally subjecting said hydrogenated imaging agent to a magnetic field having a field strength below...

  6. CEST and PARACEST MR contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Hancu, Ileana; Dixon, W. Thomas (GE Global Research Center, Niskayuna, NY (United States)); Woods, Mark; Sherry, A. Dean (Univ. of Texas at Dallas, Dallas, TX (United States)); Vinogradov, Elena; Lenkinski, Robert E. (Beth Israel Deaconess Medical Center, Boston, MA (United States)), e-mail: rlenkins@bidmc.harvard.edu

    2010-10-15

    In this review we describe the status of development for a new class of magnetic resonance (MR) contrast agents, based on chemical exchange saturation transfer (CEST). The mathematics and physics relevant to the description of the CEST effect in MR are presented in an appendix published in the online version only. We discuss the issues arising when translating in vitro results obtained with CEST agents to using these MR agents in in vivo model studies and in humans. Examples are given on how these agents are imaged in vivo. We summarize the status of development of these CEST agents, and speculate about the next steps that may be taken towards the demonstration of CEST MR imaging in clinical applications

  7. Severe thrombocytopenia induced by iodinated contrast after coronary angiography: The use of gadolinium contrast and intravascular ultrasound as an alternative to guide percutaneous coronary intervention.

    Science.gov (United States)

    Cubero-Gómez, José María; Guerrero Márquez, Francisco J; Diaz-de la-Llera, Luis; Fernández-Quero, Mónica; Guisado-Rasco, Agustín; Villa-Gil-Ortega, Manuel

    2017-01-01

    Acute contrast-induced thrombocytopenia is a rare event with the use of modern low osmolarity iodinated contrast media. The pathophysiological mechanism that causes platelet counts to drop has not been identified, but an immunological mechanism is suspected due to cytotoxicity after previous exposure to contrast. We report the case of a 47-year-old male patient with acute severe thrombocytopenia due to iodinated contrast media exposure. His platelet count after the procedure with the highest amount of contrast was zero, which is the lowest reported platelet count to date. Percutaneous coronary revascularization under both intravascular ultrasound and gadolinium contrast guidance was performed without complications. The most feared complication after the use of gadolinium is nephrogenic systemic fibrosis, especially in patients on hemodialysis. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Relaxivity of liposomal paramagnetic MRI contrast agents

    NARCIS (Netherlands)

    Strijkers, G. J.; Mulder, W. J. M.; van Heeswijk, R. B.; Frederik, P. M.; Bomans, P.; Magusin, P. C. M. M.; Nicolay, K.

    2005-01-01

    Paramagnetic liposomes, spherical particles formed by a lipid bilayer, are able to accommodate a high payload of Gd-containing lipid and therefore can serve as a highly potent magnetic resonance imaging contrast agent. In this paper the relaxation properties of paramagnetic liposomes were studied as

  9. Contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Karadjian, V.

    1987-01-01

    The origine of nuclear magnetic resonance signal is reminded and different ways for contrast enhancement in magnetic resonance imaging are presented, especially, modifications of tissus relaxation times. Investigations have focused on development of agents incorporating either paramagnetic ions or stable free radicals. Pharmacological and toxicological aspects are developed. The diagnostic potential of these substances is illustrated by the example of gadolinium complexes [fr

  10. 20 years of ultrasound contrast agent modeling

    NARCIS (Netherlands)

    Faez, T.; Emmer, M.; Kooiman, K.; Versluis, Michel; van der Steen, A.F.W.; de Jong, N.

    2013-01-01

    The merits of ultrasound contrast agents (UCAs) were already known in the 1960s. It was, however, not until the 1990s that UCAs were clinically approved and marketed. In these years, it was realized that the UCAs are not just efficient ultrasound scatterers, but that their main constituent, the

  11. Nonspherical oscilllations of ultrasound contrast agent microbubbles

    NARCIS (Netherlands)

    Dollet, B.; van der Meer, S.M.; Garbin, V.; Garbin, Valeria; de Jong, N.; Lohse, Detlef; Versluis, Michel

    2008-01-01

    The occurrence of nonspherical oscillations (or surface modes) of coated microbubbles, used as ultrasound contrast agents in medical imaging, is investigated using ultra–high-speed optical imaging. Optical tweezers designed to micromanipulate single bubbles in 3-D are used to trap the bubbles far

  12. Ultrasonic characterization of ultrasound contrast agents

    NARCIS (Netherlands)

    N. de Jong (Nico); M. Emmer (Marcia); A. van Wamel (Annemieke); M. Versluis (Michel)

    2009-01-01

    textabstractThe main constituent of an ultrasound contrast agent (UCA) is gas-filled microbubbles. An average UCA contains billions per ml. These microbubbles are excellent ultrasound scatterers due to their high compressibility. In an ultrasound field they act as resonant systems, resulting in

  13. Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.

    Science.gov (United States)

    Mariani, José; Guedes, Cristiano; Soares, Paulo; Zalc, Silvio; Campos, Carlos M; Lopes, Augusto C; Spadaro, André G; Perin, Marco A; Filho, Antonio Esteves; Takimura, Celso K; Ribeiro, Expedito; Kalil-Filho, Roberto; Edelman, Elazer R; Serruys, Patrick W; Lemos, Pedro A

    2014-11-01

    The aim of this study was to evaluate the impact of intravascular ultrasound (IVUS) guidance on the final volume of contrast agent used in patients undergoing percutaneous coronary intervention (PCI). To date, few approaches have been described to reduce the final dose of contrast agent in PCIs. We hypothesized that IVUS might serve as an alternative imaging tool to angiography in many steps during PCI, thereby reducing the use of iodine contrast. A total of 83 patients were randomized to angiography-guided PCI or IVUS-guided PCI; both groups were treated according to a pre-defined meticulous procedural strategy. The primary endpoint was the total volume contrast agent used during PCI. Patients were followed clinically for an average of 4 months. The median total volume of contrast was 64.5 ml (interquartile range [IQR]: 42.8 to 97.0 ml; minimum, 19 ml; maximum, 170 ml) in the angiography-guided group versus 20.0 ml (IQR: 12.5 to 30.0 ml; minimum, 3 ml; maximum, 54 ml) in the IVUS-guided group (p MOZART]; NCT01947335). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Cardiac image segmentation for contrast agent videodensitometry.

    Science.gov (United States)

    Mischi, Massimo; Kalker, Antonius A C M; Korsten, Hendrikus H M

    2005-02-01

    Indicator dilution techniques are widely used in the intensive care unit and operating room for cardiac parameter measurements. However, the invasiveness of current techniques represents a limitation for their clinical use. The development of stable ultrasound contrast agents allows new applications of the indicator dilution method. Ultrasound contrast agent dilutions permit an echographic noninvasive measurement of cardiac output, ejection fraction, and blood volumes. The indicator dilution curves are measured by videodensitometry of specific regions of interest and processed for the cardiac parameter assessment. Therefore, the major indicator dilution imaging issue is the detection of proper contrast videodensitometry regions that maximize the signal-to-noise ratio of the measured indicator dilution curves. This paper presents an automatic contour detection algorithm for indicator dilution videodensitometry. The algorithm consists of a radial filter combined with an outlier correction. It maximizes the region of interest by excluding cardiac structures that act as interference to the videodensitometric analysis. It is fast, projection independent, and allows the simultaneous detection of multiple contours in real time. The system is compared to manual contour definition on both echographic and magnetic resonance images.

  15. Oral contrast agents in abdominal MR imaging

    International Nuclear Information System (INIS)

    Heuck, A.F.; Schhidbauer, E.; Allgayer, B.

    1991-01-01

    This paper compares Gd-DTPA, FE 2+ SO 4 , and Fe 2 Cl 3 -EDTA solutions as oral contrast agents in abdominal/pelvic MR imaging. MR imaging was performed at 1.5 T in 62 patients with tumors or inflammatory disorders of the abdomen and pelvis and in 28 normal volunteers. After precontrast imaging, an oral contrast medium was administered. Thirty subjects received 700-1,200 mL of a Gd-DTPA solution (1.0 mM; 15 g of mannitol per liter), 30 ingested the same amount of 5.0 mM Fe 2+ SO 4 , and 30 received Fe 2 Cl 3 -EDTA solution. The postcontrast study included T1- and T2-weighted spin-echo sequences and T1- and T2*-weighted gradient-echo sequences. Bowel peristalsis was reduced with intravenous application of Buscopan. Gd-DTPA, Fe 2+ SO 4 solution, and Fe 2 Cl 3 -EDTA solution provided homogeneous hyperintense signal intensity and high contrast of stomach and duodenum in all sequences, with significantly improved delineation of pathologic structures and abdominal organs in 78% of cases. Best contrast was achieved in T1-weighted sequences

  16. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery

    Directory of Open Access Journals (Sweden)

    Vera ePaefgen

    2015-09-01

    Full Text Available Ultrasound is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents. There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular contrast agents enable functional analyses, e.g. to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles’ shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by ultrasound pulses to locally release the entrapped agent. Recent studies show that ultrasound contrast agents are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of ultrasound contrast agents and introduces the current clinical applications of contrast-enhanced ultrasound. Additionally, an overview of the recent developments in ultrasound probe design for functional and molecular diagnosis as well as for drug delivery is given.

  17. Perfluorooctyl bromide emulsion contrast agent for tumors

    International Nuclear Information System (INIS)

    Tsuda, Yoshio; Ueda, Yasuo; Tanaka, Mikio; Yamanouchi, Kouichi; Yokoyama, Kazumasa

    1985-01-01

    Perfluorooctyl bromide (PFOB), a biologically inert radiodense compound, was evaluated as a potential contrast agent for tumors. When 25 w/v% PFOB emulsion was administered intravenously in rats with AH 130 tumor, the tumor became radiopaque using conventional X-rays. Rabbits were implanted into liver with VX 2 carcinoma and were given 10 ml/kg PFOB emulsion intravenously. Computed tomographic scanning of the rabbits showed the dense enhancement of the rim of the tumor. The PFOB contents in the tumor, the tumor-rim and the normal liver tissues were determined by gas chromatography. The differences of PFOB contents in three different locations showed the density of the tumor rim was due to the accumulation of PFOB in the periphery of the tumor. Optical and electron microscopy revealed lots of vaculoes of PFOB particles in macrophages around the tumor. Thus, PFOB emulsion may be useful in detection of tumors. (author)

  18. MRI contrast agents from molecules to particles

    CERN Document Server

    Laurent, Sophie; Stanicki, Dimitri; Boutry, Sébastien; Lipani, Estelle; Belaid, Sarah; Muller, Robert N; Vander Elst, Luce

    2017-01-01

    This book describes the multiple aspects of (i) preparation of the magnetic core, (ii) the stabilization with different coatings, (iii) the physico-chemical characterization and (iv) the vectorization to obtain specific nanosystems. Several bio-applications are also presented in this book. In the early days of Magnetic Resonance Imaging (MRI), paramagnetic ions were proposed as contrast agents to enhance the diagnostic quality of MR images. Since then, academic and industrial efforts have been devoted to the development of new and more efficient molecular, supramolecular and nanoparticular systems. Old concepts and theories, like paramagnetic relaxation, were revisited and exploited, leading to new scientific tracks. With their high relaxivity payload, the superparamagnetic nanoparticles are very appealing in the context of molecular imaging but challenges are still numerous: absence of toxicity, specificity, ability to cross the biological barriers, etc. .

  19. Synthesis of Laboratory Ultrasound Contrast Agents

    Directory of Open Access Journals (Sweden)

    Jaemin Oh

    2013-10-01

    Full Text Available Ultrasound Contrast Agents (UCAs were developed to maximize reflection contrast so that organs can be seen clearly in ultrasound imaging. UCAs increase the signal to noise ratio (SNR by linear and non-linear mechanisms and thus help more accurately visualize the internal organs and blood vessels. However, the UCAs on the market are not only expensive, but are also not optimized for use in various therapeutic research applications such as ultrasound-aided drug delivery. The UCAs fabricated in this study utilize conventional lipid and albumin for shell formation and perfluorobutane as the internal gas. The shape and density of the UCA bubbles were verified by optical microscopy and Cryo SEM, and compared to those of the commercially available UCAs, Definity® and Sonovue®. The size distribution and characteristics of the reflected signal were also analyzed using a particle size analyzer and ultrasound imaging equipment. Our experiments indicate that UCAs composed of spherical microbubbles, the majority of which were smaller than 1 um, were successfully synthesized. Microbubbles 10 um or larger were also identified when different shell characteristics and filters were used. These laboratory UCAs can be used for research in both diagnoses and therapies.

  20. Dendrimer-based Macromolecular MRI Contrast Agents: Characteristics and Application

    Directory of Open Access Journals (Sweden)

    Hisataka Kobayashi

    2003-01-01

    Full Text Available Numerous macromolecular MRI contrast agents prepared employing relatively simple chemistry may be readily available that can provide sufficient enhancement for multiple applications. These agents operate using a ~100-fold lower concentration of gadolinium ions in comparison to the necessary concentration of iodine employed in CT imaging. Herein, we describe some of the general potential directions of macromolecular MRI contrast agents using our recently reported families of dendrimer-based agents as examples. Changes in molecular size altered the route of excretion. Smaller-sized contrast agents less than 60 kDa molecular weight were excreted through the kidney resulting in these agents being potentially suitable as functional renal contrast agents. Hydrophilic and larger-sized contrast agents were found better suited for use as blood pool contrast agents. Hydrophobic variants formed with polypropylenimine diaminobutane dendrimer cores created liver contrast agents. Larger hydrophilic agents are useful for lymphatic imaging. Finally, contrast agents conjugated with either monoclonal antibodies or with avidin are able to function as tumor-specific contrast agents, which also might be employed as therapeutic drugs for either gadolinium neutron capture therapy or in conjunction with radioimmunotherapy.

  1. Magnetic resonance angiography with blood-pool contrast agents: future applications

    International Nuclear Information System (INIS)

    Fink, C.; Goyen, M.; Lotz, J.

    2007-01-01

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  2. Gadolinium-based contrast agents in pediatric magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gale, Eric M.; Caravan, Peter [Massachusetts General Hospital, Harvard Medical School, Department of Radiology, The Martinos Center for Biomedical Imaging, Boston, MA (United States); Rao, Anil G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); McDonald, Robert J. [College of Medicine, Mayo Clinic, Department of Radiology, Rochester, MN (United States); Winfeld, Matthew [University of Pennsylvania Perelman School of Medicine, Philadelphia, PA (United States); Fleck, Robert J. [Cincinnati Children' s Hospital Medical Center, Department of Pediatric Radiology, Cincinnati, OH (United States); Gee, Michael S. [MassGeneral Hospital for Children, Harvard Medical School, Division of Pediatric Imaging, Department of Radiology, Boston, MA (United States)

    2017-05-15

    Gadolinium-based contrast agents can increase the accuracy and expediency of an MRI examination. However the benefits of a contrast-enhanced scan must be carefully weighed against the well-documented risks associated with administration of exogenous contrast media. The purpose of this review is to discuss commercially available gadolinium-based contrast agents (GBCAs) in the context of pediatric radiology. We discuss the chemistry, regulatory status, safety and clinical applications, with particular emphasis on imaging of the blood vessels, heart, hepatobiliary tree and central nervous system. We also discuss non-GBCA MRI contrast agents that are less frequently used or not commercially available. (orig.)

  3. Gadolinium-based contrast agents in pediatric magnetic resonance imaging

    International Nuclear Information System (INIS)

    Gale, Eric M.; Caravan, Peter; Rao, Anil G.; McDonald, Robert J.; Winfeld, Matthew; Fleck, Robert J.; Gee, Michael S.

    2017-01-01

    Gadolinium-based contrast agents can increase the accuracy and expediency of an MRI examination. However the benefits of a contrast-enhanced scan must be carefully weighed against the well-documented risks associated with administration of exogenous contrast media. The purpose of this review is to discuss commercially available gadolinium-based contrast agents (GBCAs) in the context of pediatric radiology. We discuss the chemistry, regulatory status, safety and clinical applications, with particular emphasis on imaging of the blood vessels, heart, hepatobiliary tree and central nervous system. We also discuss non-GBCA MRI contrast agents that are less frequently used or not commercially available. (orig.)

  4. Nanoparticle Contrast Agents for Computed Tomography: A Focus on Micelles

    Science.gov (United States)

    Cormode, David P.; Naha, Pratap C.; Fayad, Zahi A.

    2014-01-01

    Computed tomography (CT) is an X-ray based whole body imaging technique that is widely used in medicine. Clinically approved contrast agents for CT are iodinated small molecules or barium suspensions. Over the past seven years there has been a great increase in the development of nanoparticles as CT contrast agents. Nanoparticles have several advantages over small molecule CT contrast agents, such as long blood-pool residence times, and the potential for cell tracking and targeted imaging applications. Furthermore, there is a need for novel CT contrast agents, due to the growing population of renally impaired patients and patients hypersensitive to iodinated contrast. Micelles and lipoproteins, a micelle-related class of nanoparticle, have notably been adapted as CT contrast agents. In this review we discuss the principles of CT image formation and the generation of CT contrast. We discuss the progress in developing non-targeted, targeted and cell tracking nanoparticle CT contrast agents. We feature agents based on micelles and used in conjunction with spectral CT. The large contrast agent doses needed will necessitate careful toxicology studies prior to clinical translation. However, the field has seen tremendous advances in the past decade and we expect many more advances to come in the next decade. PMID:24470293

  5. Magnetic Resonance Imaging Contrast Agents: A Review of Literature

    Directory of Open Access Journals (Sweden)

    Zahra Sahraei

    2015-10-01

    Full Text Available  Magnetic Resonance Imaging (MRI contrast agents most commonly agents used in diagnosing different diseases. Several agents have been ever introduced with different peculiar characteristics. They vary in potency, adverse reaction and other specification, so it is important to select the proper agent in different situations. We conducted a systematic literature search in MEDLINE/PUBMED, Web of Science (ISI, Scopus,Google Scholar by using keywords "gadolinium" and "MRI contrast Medias", "Gadofosvest", "Gadobenate" and "Gadoxetate". The most frequent contrast media agents made based on gadolinium (Gd. These are divided into two categories based on the structure of their chelating parts, linear agents and macrocyclic agents. All characteristics of contrast media factors, including efficiency, kinetic properties, stability, side effects and the rate of resolution are directly related to the structure of chelating part of that formulation.In vitro data has shown that the macrocyclic compounds are the most stable Gd-CA as they do not bind to serum proteins, they all possess similar and relatively low relaxivity and the prevalence of Nephrogenic Systemic Fibrosis (NSF has decreased by increasing the use of macrocyclic agents in recent years. No cases of NSF have been recorded after the administration of any of the high-relaxivity protein interacting agents, the vascular imaging agent gadofosveset trisodium (Ablavar, the hepatic imaging agent gadoxetate meglumine (Eovist, and the multipurpose agent gadobenate dimeglumine (MultiHance. In pregnancy and lactating women, stable macrocyclic agent is recommended.

  6. Inadvertent intrathecal use of ionic contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Leede, H. van der; Jorens, P.G. [Department of Intensive Care Medicine, University Hospital of Antwerp, Wilrijkstraat 10, 2650 Edegem (Belgium); Parizel, P. [Department of Radiology, University Hospital of Antwerp, Wilrijkstraat 10, 2650 Edegem (Belgium); Cras, P. [Department of Neurology, University Hospital of Antwerp, Wilrijkstraat 10, 2650 Edegem (Belgium)

    2002-07-01

    Intrathecal administration of ionic contrast media may cause severe and fatal neurotoxic reactions due to their hyperosmolarity and ionic nature. They are therefore strictly contraindicated for all radiologic applications involving the central nervous system (e.g., myelography). We present a case in which ioxitalamate was accidentally injected intrathecally. The patient recovered completely due to a combination of the different therapeutic options reported in the literature, including early mechanical ventilation and neuromuscular paralysis, aggressive control of seizures, elevation of head and trunk to prevent cephalad migration of contrast, steroids, cerebrospinal fluid drainage and lavage and prophylactic antibiotics. (orig.)

  7. Inadvertent intrathecal use of ionic contrast agent

    International Nuclear Information System (INIS)

    Leede, H. van der; Jorens, P.G.; Parizel, P.; Cras, P.

    2002-01-01

    Intrathecal administration of ionic contrast media may cause severe and fatal neurotoxic reactions due to their hyperosmolarity and ionic nature. They are therefore strictly contraindicated for all radiologic applications involving the central nervous system (e.g., myelography). We present a case in which ioxitalamate was accidentally injected intrathecally. The patient recovered completely due to a combination of the different therapeutic options reported in the literature, including early mechanical ventilation and neuromuscular paralysis, aggressive control of seizures, elevation of head and trunk to prevent cephalad migration of contrast, steroids, cerebrospinal fluid drainage and lavage and prophylactic antibiotics. (orig.)

  8. Electric and magnetic properties of contrast agents for thermoacoustic imaging

    Science.gov (United States)

    Ogunlade, Olumide; Beard, Paul

    2014-03-01

    The endogenous contrast in thermoacoustic imaging is due to the water and ionic content in tissue. This results in poor tissue speci city between high water content tissues. As a result, exogenous contrast agents have been employed to improve tissue speci city and also increase the SNR. An investigation into the sources of contrast produced by several exogenous contrast agents is described. These include three gadolinium based MRI contrast agents, iron oxide particles, single wall carbon nanotubes, saline and sucrose solutions. Both the dielectric and magnetic properties of contrast agents at 3GHz have been measured using microwave resonant cavities. The DC conductivity of the contrast agents were also measured. It is shown that the measured increase in dielectric contrast, relative to water, is due to dipole rotational loss of polar non electrolytes, ionic loss of electrolytes or a combination of both. It is shown that for the same dielectric contrast, electrolytes make better thermoacoustic contrast agents than non-electrolytes, for thermoacoustic imaging.

  9. The optimal use of contrast agents at high field MRI

    International Nuclear Information System (INIS)

    Trattnig, Siegfried; Pinker, Kathia; Ba-Ssalamah, Ahmed; Noebauer-Huhmann, Iris-Melanie

    2006-01-01

    The intravenous administration of a standard dose of conventional gadolinium-based contrast agents produces higher contrast between the tumor and normal brain at 3.0 Tesla (T) than at 1.5 T, which allows reducing the dose to half of the standard one to produce similar contrast at 3.0 T compared to 1.5 T. The assessment of cumulative triple-dose 3.0 T images obtained the best results in the detection of brain metastases compared to other sequences. The contrast agent dose for dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging at 3.0 T can be reduced to 0.1 mmol compared to 0.2 mmol at 1.5 T due to the increased susceptibility effects at higher magnetic field strengths. Contrast agent application makes susceptibility-weighted imaging (SWI) at 3.0 T clinically attractive, with an increase in spatial resolution within the same scan time. Whereas a double dose of conventional gadolinium-based contrast agents was optimal in SWI with respect to sensitivity and image quality, a standard dose of gadobenate dimeglumine, which has a two-fold higher T1-relaxivity in blood, produced the same effect. For MR-arthrography, optimized concentrations of gadolinium-based contrast agents are similar at 3.0 and 1.5 T. In summary, high field MRI requires the optimization of the contrast agent dose in different clinical applications. (orig.)

  10. Contrast agents and renal cell apoptosis.

    Science.gov (United States)

    Romano, Giulia; Briguori, Carlo; Quintavalle, Cristina; Zanca, Ciro; Rivera, Natalia V; Colombo, Antonio; Condorelli, Gerolama

    2008-10-01

    Contrast media (CM) induce a direct toxic effect on renal tubular cells. This toxic effect may have a role in the pathophysiology of contrast nephropathy. We evaluated (i) the cytotoxicity of CM [both low-osmolality (LOCM) and iso-osmolality (IOCM)], of iodine alone, and of an hyperosmolar solution (mannitol 8%) on human embryonic kidney (HEK 293), porcine proximal renal tubular (LLC-PK1), and canine Madin-Darby distal tubular renal (MDCK) cells; and (ii) the effectiveness of various antioxidant compounds [n-acetylcysteine (NAC), ascorbic acid and sodium bicarbonate] in preventing CM cytotoxicity. The cytotoxicity of CM was assessed at different time points, with different methods: cell viability, DNA laddering, flow cytometry, and caspase activation. Both LOCM and IOCM produced a concentration- and time-dependent increase in cell death as assessed by the different methods. On the contrary, iodine alone and hyperosmolar solution did not induce any significant cytotoxic effect. There was not any significant difference in the cytotoxic effect between LOCM and IOCM. Furthermore, both LOCM and IOCM caused a marked increase in caspase-3 and -9 activities and poly(ADP-ribose) fragmentation, while no effect on caspase-8/-10 was observed, thus indicating that the CM activated apoptosis mainly through the intrinsic pathway. Both CM induced an increase in protein expression levels of pro-apoptotic members of the Bcl2 family (Bim and Bad). NAC and ascorbic acid but not sodium bicarbonate had a dose-dependent protective effect on renal cells after 3 h incubation with high dose (200 mg iodine/mL) of both LOCM and IOCM. Both LOCM and IOCM induce a dose-dependent renal cell apoptosis. NAC and ascorbic acid but not sodium bicarbonate prevent this contrast-induced apoptosis.

  11. Contrast Agent in Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Vu-Quang, Hieu

    2015-01-01

    cancer cells for cancer diagnosis in MRI. F127-Folate coated SPION were stable in various types of suspension medium for over six months. They could specifically target folate receptor of cancer cells in vitro and in vivo thus enhancing the contrast in MRI T2/T2* weighted images. These are preliminary...... for chemotherapy. The nanoparticles were 150 nm in size with spherical shape, which contained PFOB in the inner core and Dox and ICG in the polymeric shell. More importantly, they could target folate receptor expressing cancer cells, which provide positive in vitro and in vivo NIR and 19F MRI results. In project...

  12. Fundamental studies of oral contrast agents for MR. Comparison of manganese agent and iron agent

    International Nuclear Information System (INIS)

    Fujita, Osamu; Hiraishi, Kumiko; Suginobu, Yoshito; Takeuchi, Masayasu; Narabayashi, Isamu

    1996-01-01

    We investigated and compared signal intensity and the effect of imaging the upper abdomen with blueberry juice (B.J.), a Mn agent utilizing the properties of paramagnetic metals, and FerriSeltz (F.S.), an iron agent. Since the relaxation effect was much stronger with B.J. than with F.S., the signal intensity required of a peroral contrast agent was able to be obtained at a much lower concentration of B.J. In imaging the upper abdomen, B.J. had a positive effect on imaging in T1-weighted images, and a negative effect in T2-weighted images. F.S. had a positive imaging effect in both, and because it showed extremely high signals in T2-weighted images, motion artifact arose. (author)

  13. A brief account of nanoparticle contrast agents for photoacoustic imaging.

    Science.gov (United States)

    Pan, Dipanjan; Kim, Benjamin; Wang, Lihong V; Lanza, Gregory M

    2013-01-01

    Photoacoustic imaging (PAI) is a hybrid, nonionizing modality offering excellent spatial resolution, deep penetration, and high soft tissue contrast. In PAI, signal is generated based on the absorption of laser-generated optical energy by endogenous tissues or exogenous contrast agents leading to acoustic emissions detected by an ultrasound transducer. Research in this area over the years has shown that PAI has the ability to provide both physiological and molecular imaging, which can be viewed alone or used in a hybrid modality fashion to extend the anatomic and hemodynamic sensitivities of clinical ultrasound. PAI may be performed using inherent contrast afforded by light absorbing molecules such as hemoglobin, myoglobin, and melanin or exogenous small molecule contrast agent such as near infrared dyes and porphyrins. However, this review summarizes the potential of exogenous nanoparticle-based agents for PAI applications including contrast based on gold particles, carbon nanotubes, and encapsulated copper compounds. Copyright © 2013 Wiley Periodicals, Inc.

  14. The clinical use of contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bydder, G.M.

    1987-01-01

    Interest in the use of external agents to increase tissue contrasts has come from many sources dating back to the earliest work in NMR, to animal studies and to the widespread use of contrast agents in conventional radiological practice. The first clinical magnetic resonance images were published in 1980 and in the following year a brief account of the use of the paramagnetic agents in human volunteers was established. It was apparent relatively early in the development of magnetic resonance imaging (MRI) that a high level of soft tissue contrast was available de novo and the need for externally administered agents might therefore be small. This observation was tempered by the fact that separation of tumour from oedema was frequently better with contrast enhanced CT X-ray than with unenhanced MRI and that of a contrast agent might therefore be needed for MRI. At the end of 1983 the first parenteral agent gadoliminum diethylene triamine pentaacetic acid (Gd-DTPA) was used in volunteers and clinical studies began in 1984. At the present time only molecular O/sub 2/, oral iron compounds and Gd-DTPA are in clinical use although there are a number of other agents which have been used in animals and some of these may become available for clinical use in the foreseeable future

  15. Modified natural nanoparticles as contrast agents for medical imaging

    NARCIS (Netherlands)

    Cormode, David P.; Jarzyna, Peter A.; Mulder, Willem J. M.; Fayad, Zahi A.

    2010-01-01

    The development of novel and effective contrast agents is one of the drivers of the ongoing improvement in medical imaging. Many of the new agents reported are nanoparticle-based. There are a variety of natural nanoparticles known, e.g. lipoproteins, viruses or ferritin. Natural nanoparticles have

  16. Cationic Contrast Agent Diffusion Differs Between Cartilage and Meniscus.

    Science.gov (United States)

    Honkanen, Juuso T J; Turunen, Mikael J; Freedman, Jonathan D; Saarakkala, Simo; Grinstaff, Mark W; Ylärinne, Janne H; Jurvelin, Jukka S; Töyräs, Juha

    2016-10-01

    Contrast enhanced computed tomography (CECT) is a non-destructive imaging technique used for the assessment of composition and structure of articular cartilage and meniscus. Due to structural and compositional differences between these tissues, diffusion and distribution of contrast agents may differ in cartilage and meniscus. The aim of this study is to determine the diffusion kinematics of a novel iodine based cationic contrast agent (CA(2+)) in cartilage and meniscus. Cylindrical cartilage and meniscus samples (d = 6 mm, h ≈ 2 mm) were harvested from healthy bovine knee joints (n = 10), immersed in isotonic cationic contrast agent (20 mgI/mL), and imaged using a micro-CT scanner at 26 time points up to 48 h. Subsequently, normalized X-ray attenuation and contrast agent diffusion flux, as well as water, collagen and proteoglycan (PG) contents in the tissues were determined. The contrast agent distributions within cartilage and meniscus were different. In addition, the normalized attenuation and diffusion flux were higher (p meniscus. These tissue specific variations can affect the interpretation of CECT images and should be considered when cartilage and meniscus are assessed simultaneously.

  17. Contrast agents for photoacoustic and thermoacoustic imaging: a review.

    Science.gov (United States)

    Wu, Dan; Huang, Lin; Jiang, Max S; Jiang, Huabei

    2014-12-18

    Photoacoustic imaging (PAI) and thermoacoustic imaging (TAI) are two emerging biomedical imaging techniques that both utilize ultrasonic signals as an information carrier. Unique advantages of PAI and TAI are their abilities to provide high resolution functional information such as hemoglobin and blood oxygenation and tissue dielectric properties relevant to physiology and pathology. These two methods, however, may have a limited detection depth and lack of endogenous contrast. An exogenous contrast agent is often needed to effectively resolve these problems. Such agents are able to greatly enhance the imaging contrast and potentially break through the imaging depth limit. Furthermore, a receptor-targeted contrast agent could trace the molecular and cellular biological processes in tissues. Thus, photoacoustic and thermoacoustic molecular imaging can be outstanding tools for early diagnosis, precise lesion localization, and molecular typing of various diseases. The agents also could be used for therapy in conjugation with drugs or in photothermal therapy, where it functions as an enhancer for the integration of diagnosis and therapy. In this article, we present a detailed review about various exogenous contrast agents for photoacoustic and thermoacoustic molecular imaging. In addition, challenges and future directions of photoacoustic and thermoacoustic molecular imaging in the field of translational medicine are also discussed.

  18. Contrast Agents for Photoacoustic and Thermoacoustic Imaging: A Review

    Directory of Open Access Journals (Sweden)

    Dan Wu

    2014-12-01

    Full Text Available Photoacoustic imaging (PAI and thermoacoustic imaging (TAI are two emerging biomedical imaging techniques that both utilize ultrasonic signals as an information carrier. Unique advantages of PAI and TAI are their abilities to provide high resolution functional information such as hemoglobin and blood oxygenation and tissue dielectric properties relevant to physiology and pathology. These two methods, however, may have a limited detection depth and lack of endogenous contrast. An exogenous contrast agent is often needed to effectively resolve these problems. Such agents are able to greatly enhance the imaging contrast and potentially break through the imaging depth limit. Furthermore, a receptor-targeted contrast agent could trace the molecular and cellular biological processes in tissues. Thus, photoacoustic and thermoacoustic molecular imaging can be outstanding tools for early diagnosis, precise lesion localization, and molecular typing of various diseases. The agents also could be used for therapy in conjugation with drugs or in photothermal therapy, where it functions as an enhancer for the integration of diagnosis and therapy. In this article, we present a detailed review about various exogenous contrast agents for photoacoustic and thermoacoustic molecular imaging. In addition, challenges and future directions of photoacoustic and thermoacoustic molecular imaging in the field of translational medicine are also discussed.

  19. WE-C-218-01: Ultrasound Contrast Agents.

    Science.gov (United States)

    Streeter, J E; Dayton, P A

    2012-06-01

    Medical ultrasound has long been used in clinical applications both as a primary modality and as a supplement to other diagnostic procedures. The basis for ultrasound imaging is the transmission of high frequency (megaHertz) sound waves that propagate through tissue. These sound waves backscatter from the interfaces between tissue components with different acoustic properties and are detected by the imaging system, allowing the creation of images based on tissue characteristics and spatial location. Thus, traditional ultrasound has focused primarily on the imaging of anatomical structures and analysis of blood flow in large vessels. Unfortunately, blood is a weak scatterer, which can make vascular diagnostic applications (example: echocardiography) challenging especially with larger patients. Contrast agents help to improve on this shortcoming by enhancing the visualization of blood flow, thus improving the quality of diagnostics. The use of contrast agents for ultrasound was first reported in 1968 when Gramiak and Shah discovered that there was an increased backscatter of ultrasound caused by injected microbubbles. This is because the mismatch in acoustic impedance (a function of an object's density and compressibility) between the microbubble gas core and blood (or tissue) is several orders of magnitude, which results in substantially higher scattering from a bubble than an equivalent volume of tissue or blood. Additionally, microbubbles oscillate in response to an ultrasound field, and respond non-linearly to acoustic pulses even at low energies, unlike tissue. The non-linear property of microbubbles in an ultrasound field allows for the use of various pulsing and signal processing strategies to detect the backscattered signal from contrast agents and segment it from tissue, thus providing a high contrast-to- noise ratio. Due to these unique acoustic properties, a clinical ultrasound system can detect even single microbubble contrast agents, providing exquisite

  20. Feasibility of concurrent dual contrast enhancement using CEST contrast agents and superparamagnetic iron oxide particles.

    NARCIS (Netherlands)

    Gilad, A.A.; Laarhoven, H.W.M. van; McMahon, M.T.; Walczak, P.; Heerschap, A.; Neeman, M.; Zijl, P.C. van; Bulte, J.W.

    2009-01-01

    A major challenge for cellular and molecular MRI is to study interactions between two different cell populations or biological processes. We studied the possibility to simultaneously image contrast agents based on two different MRI contrast mechanisms: chemical exchange saturation transfer (CEST)

  1. Contrast enhancement by lipid-based MRI contrast agents in mouse atherosclerotic plaques; a longitudinal study

    NARCIS (Netherlands)

    den Adel, Brigit; van der Graaf, Linda M.; Que, Ivo; Strijkers, Gustav J.; Löwik, Clemens W.; Poelmann, Robert E.; van der Weerd, Louise

    2013-01-01

    The use of contrast-enhanced MRI to enable in vivo specific characterization of atherosclerotic plaques is increasing. In this study the intrinsic ability of two differently sized gadolinium-based contrast agents to enhance atherosclerotic plaques in ApoE(-/-) mice was evaluated with MRI. We

  2. Feasibility of concurrent dual contrast enhancement using CEST contrast agents and superparamagnetic iron oxide particles

    NARCIS (Netherlands)

    Gilad, Assaf A.; van Laarhoven, Hanneke W. M.; McMahon, Michael T.; Walczak, Piotr; Heerschap, Arend; Neeman, Michal; van Zijl, Peter C. M.; Bulte, Jeff W. M.

    2009-01-01

    A major challenge for cellular and molecular MRI is to study interactions between two different cell populations or biological processes. We studied the possibility to simultaneously image contrast agents based on two different MRI contrast mechanisms: chemical exchange saturation transfer (CEST)

  3. Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

    International Nuclear Information System (INIS)

    Ogunlade, Olumide; Beard, Paul

    2015-01-01

    Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substance to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type

  4. Evaluation of potential gastrointestinal contrast agents for echoplanar MR imaging

    International Nuclear Information System (INIS)

    Reimer, P.; Schmitt, F.; Ladebeck, R.; Graessner, J.; Schaffer, B.

    1993-01-01

    The purpose of this study was to investigate approved aqueous gastrointestinal contrast agents for use in abdominal EPI. Conventional and echoplanar MR imaging experiments were performed with 1.0 Tesla whole body systems. Phantom measurements of Gastrografin, barium sulfate suspension, oral gadopentetate dimeglumine, water, and saline were performed. Signal intensity (SI) of aqueous oral barium sulfate and iodine based CT contrast agents was lower on conventional spin-echo (SE), Flash, and Turbo-Flush images than on EP images. The contrast agents exhibited higher SI on T2-weighted SE PE images and TI-time dependence on inversion recovery EP-images. The barium sulfate suspension was administered in volunteers to obtain information about bowel lumen enhancement and susceptibility artifacts. Oral administration of the aqueous barium sulfate suspension increased bowel lumen signal and reduced susceptibility artifacts. (orig.)

  5. Influence of radiographic contrast agents on quantitative coronary angiography

    International Nuclear Information System (INIS)

    Jost, Stefan; Hausmann, Dirk; Lippolt, Peter; Gerhardt, Uwe; Lichtlen, Paul R.

    1997-01-01

    Purpose. Quantitative angiographic studies on the vasomotility of epicardial coronary arteries are gaining increasing relevance. We investigated whether radiographic contrast agents might influence coronary vasomotor tone and thereby the results of such studies. Methods. Coronary angiograms were taken in 12 patients with coronary artery disease at intervals of 5, 3, 2, and 1 min with the low-osmolar, nonionic contrast agent iopamidol 300, and were repeated at identical intervals with the high-osmolar, ionic agent diatrizoate 76%. Results. Quantitative cine film analysis demonstrated no significant diameter changes in angiographically normal and stenotic coronary arteries with iopamidol. With diatrizoate, however, normal segments were dilated 2%±2% (p<0.01) after 2 min and 10%±3% after the 1 min interval (p<0.001). Stenoses showed no uniform responses to diatrizoate. Conclusion. Low-osmolar, nonionic contrast agents should be preferred for quantitative angiographic studies on epicardial coronary vasomotility. When using ionic contrast agents, injection intervals of at least 3 min are required

  6. Gd-HOPO Based High Relaxivity MRI Contrast Agents

    Energy Technology Data Exchange (ETDEWEB)

    Datta, Ankona; Raymond, Kenneth

    2008-11-06

    Tris-bidentate HOPO-based ligands developed in our laboratory were designed to complement the coordination preferences of Gd{sup 3+}, especially its oxophilicity. The HOPO ligands provide a hexadentate coordination environment for Gd{sup 3+} in which all he donor atoms are oxygen. Because Gd{sup 3+} favors eight or nine coordination, this design provides two to three open sites for inner-sphere water molecules. These water molecules rapidly exchange with bulk solution, hence affecting the relaxation rates of bulk water olecules. The parameters affecting the efficiency of these contrast agents have been tuned to improve contrast while still maintaining a high thermodynamic stability for Gd{sup 3+} binding. The Gd- HOPO-based contrast agents surpass current commercially available agents ecause of a higher number of inner-sphere water molecules, rapid exchange of inner-sphere water molecules via an associative mechanism, and a long electronic relaxation time. The contrast enhancement provided by these agents is at least twice that of commercial contrast gents, which are based on polyaminocarboxylate ligands.

  7. A brief account of nanoparticle contrast agents for photoacoustic imaging

    OpenAIRE

    Pan, Dipanjan; Kim, Benjamin; Wang, Lihong V.; Lanza, Gregory M.

    2013-01-01

    Photoacoustic imaging (PAI) is a hybrid, nonionizing modality offering excellent spatial resolution, deep penetration, and high soft tissue contrast. In PAI, signal is generated based on the absorption of laser-generated optical energy by endogenous tissues or exogenous contrast agents leading to acoustic emissions detected by an ultrasound transducer. Research in this area over the years has shown that PAI has the ability to provide both physiological and molecular imaging, which can be view...

  8. Safety of ultrasound contrast agents in stress echocardiography.

    Science.gov (United States)

    Gabriel, Ruvin S; Smyth, Yvonne M; Menon, Venu; Klein, Allan L; Grimm, Richard A; Thomas, James D; Sabik, Ellen Mayer

    2008-11-01

    Definity and Optison are perflutren-based ultrasound contrast agents used in echocardiography. United States Food and Drug Administration warnings regarding serious cardiopulmonary reactions and death after Definity administration highlighted the limited safety data in patients who undergo contrast stress echocardiography. From 1998 and 2007, 2,022 patients underwent dobutamine stress echocardiography and 2,764 underwent exercise stress echocardiography with contrast at the Cleveland Clinic. The echocardiographic database, patient records, and the Social Security Death Index were reviewed for the timing and cause of death, severe adverse events, arrhythmias, and symptoms. Complication rates for contrast dobutamine stress echocardiography and exercise stress echocardiography were compared with those in a control group of 5,012 patients matched for test year and type who did not receive contrast. Ninety-five percent of studies were performed in outpatients. There were no differences in the rates of severe adverse events (0.19% vs 0.17%, p = 0.7), death within 24 hours (0% vs 0.04%, p = 0.1), cardiac arrest (0.04% vs 0.04%, p = 0.96), and sustained ventricular tachycardia (0.2% vs 0.1%, p = 0.32) between patients receiving and not receiving intravenous contrast, respectively. In conclusion, severe adverse reactions to intravenous contrast agents during stress echocardiography are uncommon. Contrast use does not add to the baseline risk for severe adverse events in patients who undergo stress echocardiography.

  9. Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration.

    Science.gov (United States)

    Park, Donghee; Song, Gillsoo; Jo, Yongjun; Won, Jongho; Son, Taeyoon; Cha, Ohrum; Kim, Jinho; Jung, Byungjo; Park, Hyunjin; Kim, Chul-Woo; Seo, Jongbum

    2016-01-01

    Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa) causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with microbubbles depends on the

  10. Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration.

    Directory of Open Access Journals (Sweden)

    Donghee Park

    Full Text Available Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with

  11. Biological in situ characterization of polymeric microbubble contrast agents

    NARCIS (Netherlands)

    Wan, Sha; Egri, Gabriella; Oddo, Letizia; Cerroni, Barbara; Dähne, Lars; Paradossi, Gaio; Salvati, Anna; Lynch, Iseult; Dawson, Kenneth A; Monopoli, Marco P

    Polymeric microbubbles (MBs) are gas filled particles composed of a thin stabilized polymer shell that have been recently developed as valid contrast agents for the combined use of ultrasonography (US), magnetic resonance imaging (MRI) and single photon emission computer tomography (SPECT) imaging.

  12. Effervescent agents in the double contrast examination of the stomach

    International Nuclear Information System (INIS)

    Virkkunen, P.; Kreula, J.

    1981-01-01

    The buffer capacities of the BaSO 4 contrast media are poor. Yet the pH changes caused by effervescent agents or gastric contents are insignificant for mucosal adsorption. The increase of the viscosity and decrease of the density impair the results of the examination. (Auth.)

  13. Bubble sorting in pinched microchannels for ultrasound contrast agent enrichment

    NARCIS (Netherlands)

    Kok, Maarten; Segers, T.J.; Versluis, Michel

    2015-01-01

    Ultrasound contrast agent (UCA) suspensions contain encapsulated microbubbles with a wide size distribution, with radii between 1 and 10 μm. Medical transducers generally operate at a narrow frequency bandwidth, severely limiting the fraction of bubbles that resonates to the driving ultrasound.

  14. Acoustic bubble sorting for ultrasound contrast agent enrichment

    NARCIS (Netherlands)

    Segers, T.J.; Versluis, Michel

    2014-01-01

    An ultrasound contrast agent (UCA) suspension contains encapsulated microbubbles with a wide size distribution, with radii ranging from 1 to 10 μm. Medical transducers typically operate at a single frequency, therefore only a small selection of bubbles will resonate to the driving ultrasound pulse.

  15. Macromolecular and dendrimer-based magnetic resonance contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Bumb, Ambika; Brechbiel, Martin W. (Radiation Oncology Branch, National Cancer Inst., National Inst. of Health, Bethesda, MD (United States)), e-mail: pchoyke@mail.nih.gov; Choyke, Peter (Molecular Imaging Program, National Cancer Inst., National Inst. of Health, Bethesda, MD (United States))

    2010-09-15

    Magnetic resonance imaging (MRI) is a powerful imaging modality that can provide an assessment of function or molecular expression in tandem with anatomic detail. Over the last 20-25 years, a number of gadolinium-based MR contrast agents have been developed to enhance signal by altering proton relaxation properties. This review explores a range of these agents from small molecule chelates, such as Gd-DTPA and Gd-DOTA, to macromolecular structures composed of albumin, polylysine, polysaccharides (dextran, inulin, starch), poly(ethylene glycol), copolymers of cystamine and cystine with GD-DTPA, and various dendritic structures based on polyamidoamine and polylysine (Gadomers). The synthesis, structure, biodistribution, and targeting of dendrimer-based MR contrast agents are also discussed

  16. Ultrasound imaging beyond the vasculature with new generation contrast agents.

    Science.gov (United States)

    Perera, Reshani H; Hernandez, Christopher; Zhou, Haoyan; Kota, Pavan; Burke, Alan; Exner, Agata A

    2015-01-01

    Current commercially available ultrasound contrast agents are gas-filled, lipid- or protein-stabilized microbubbles larger than 1 µm in diameter. Because the signal generated by these agents is highly dependent on their size, small yet highly echogenic particles have been historically difficult to produce. This has limited the molecular imaging applications of ultrasound to the blood pool. In the area of cancer imaging, microbubble applications have been constrained to imaging molecular signatures of tumor vasculature and drug delivery enabled by ultrasound-modulated bubble destruction. Recently, with the rise of sophisticated advancements in nanomedicine, ultrasound contrast agents, which are an order of magnitude smaller (100-500 nm) than their currently utilized counterparts, have been undergoing rapid development. These agents are poised to greatly expand the capabilities of ultrasound in the field of targeted cancer detection and therapy by taking advantage of the enhanced permeability and retention phenomenon of many tumors and can extravasate beyond the leaky tumor vasculature. Agent extravasation facilitates highly sensitive detection of cell surface or microenvironment biomarkers, which could advance early cancer detection. Likewise, when combined with appropriate therapeutic agents and ultrasound-mediated deployment on demand, directly at the tumor site, these nanoparticles have been shown to contribute to improved therapeutic outcomes. Ultrasound's safety profile, broad accessibility and relatively low cost make it an ideal modality for the changing face of healthcare today. Aided by the multifaceted nano-sized contrast agents and targeted theranostic moieties described herein, ultrasound can considerably broaden its reach in future applications focused on the diagnosis and staging of cancer. © 2015 Wiley Periodicals, Inc.

  17. Advanced Contrast Agents for Multimodal Biomedical Imaging Based on Nanotechnology.

    Science.gov (United States)

    Calle, Daniel; Ballesteros, Paloma; Cerdán, Sebastián

    2018-01-01

    Clinical imaging modalities have reached a prominent role in medical diagnosis and patient management in the last decades. Different image methodologies as Positron Emission Tomography, Single Photon Emission Tomography, X-Rays, or Magnetic Resonance Imaging are in continuous evolution to satisfy the increasing demands of current medical diagnosis. Progress in these methodologies has been favored by the parallel development of increasingly more powerful contrast agents. These are molecules that enhance the intrinsic contrast of the images in the tissues where they accumulate, revealing noninvasively the presence of characteristic molecular targets or differential physiopathological microenvironments. The contrast agent field is currently moving to improve the performance of these molecules by incorporating the advantages that modern nanotechnology offers. These include, mainly, the possibilities to combine imaging and therapeutic capabilities over the same theranostic platform or improve the targeting efficiency in vivo by molecular engineering of the nanostructures. In this review, we provide an introduction to multimodal imaging methods in biomedicine, the sub-nanometric imaging agents previously used and the development of advanced multimodal and theranostic imaging agents based in nanotechnology. We conclude providing some illustrative examples from our own laboratories, including recent progress in theranostic formulations of magnetoliposomes containing ω-3 poly-unsaturated fatty acids to treat inflammatory diseases, or the use of stealth liposomes engineered with a pH-sensitive nanovalve to release their cargo specifically in the acidic extracellular pH microenvironment of tumors.

  18. Ferrimagnetic ferritin cage nanoparticles used as MRI contrast agent

    Science.gov (United States)

    Cai, Y.; Cao, C.; Zhang, T.; Xu, H.; Pan, Y.

    2017-12-01

    The nano-sized ferrimagnetic ferritin cage nanoparticles are ideal materials for understanding of superparamagnetism, biomimetic synthesis of ultrafine magnetic particles and their application in biomedicine. Ferrimagnetic M-HFn nanoparticles with size of magnetite cores in a mean size ranges from 2.7 nm to 5.3 nm were synthesized through loading different amount of iron into recombinant human H chain ferritin (HFn) shells. Both the saturation magnetization (Ms) and blocking temperature (Tb) were increased with the size of ferrimagnetic cores. In essence, magnetic resonance imaging (MRI) analysis showed that the synthesized M-HFn nanoparticles (5.3 nm magnetite core) has extremely high transverse relaxivity (r2) values up to 320.9 mM-1S-1, which indicate that M-HFn nanoparticles are promising negative contrast agent in early detection of tumors. In addition, the longitudinal relaxivity (r1) (10.4 mM-1S-1) and r2/r1 ratio ( 2.2) of M-HFn nanoparticles ( 2.7 nm magnetite core in diameter) will make it a considerable potential as a positive contrast agent in MRI. This means the M-HFn nanoparticles can be used as dual functional MR contrast agent. Acute toxicity study of M-HFn in rats showed that a dosage of 20 mg Fe/kg makes no abnormalities by serum biochemical and hematological analysis as well as histopathological examination. Compared with a similar commercial contrast agent, combidex (with a clinical dosage of 2.7 mg Fe/kg), it indicates that M-HFn nanoparticle is of a relative safe ferrimagnetic nanoparticle when used in vivo.

  19. Towards MRI T2 contrast agents of increased efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Branca, Marlène [CNRS, LCC (Laboratoire de Chimie de Coordination), 205, route de Narbonne, F-31077 Toulouse (France); Université de Toulouse, UPS, INPT, LCC, F-31077 Toulouse (France); Marciello, Marzia, E-mail: marziamarciello@icmm.csic.es [Instituto de Ciencia de Materiales de Madrid (ICMM-CSIC), Sor Juana Inés de la Cruz, 3, Cantoblanco, 28049 Madrid (Spain); Ciuculescu-Pradines, Diana [CNRS, LCC (Laboratoire de Chimie de Coordination), 205, route de Narbonne, F-31077 Toulouse (France); Université de Toulouse, UPS, INPT, LCC, F-31077 Toulouse (France); Respaud, Marc [LPCNO, INSA, 135 Avenue de Rangueil, 31077 Toulouse Cedex 4 (France); Morales, Maria del Puerto [Instituto de Ciencia de Materiales de Madrid (ICMM-CSIC), Sor Juana Inés de la Cruz, 3, Cantoblanco, 28049 Madrid (Spain); Serra, Raphael; Casanove, Marie-José [CNRS, CEMES (Centre d' Elaboration des Matériaux et d' Etudes Structurales) (France); Amiens, Catherine, E-mail: catherine.amiens@lcc-toulouse.fr [CNRS, LCC (Laboratoire de Chimie de Coordination), 205, route de Narbonne, F-31077 Toulouse (France); Université de Toulouse, UPS, INPT, LCC, F-31077 Toulouse (France)

    2015-03-01

    Magnetic nanoparticles can be efficient contrast agents for T2 weighted magnetic resonance imaging (MRI) after tuning of some key parameters such as size, surface state, colloidal stability and magnetization, thus motivating the development of new synthetic pathways. In this paper we report the effects of surface coating on the efficiency of two different types of iron based nanoparticles (NPs) as MRI contrast agents. Starting from well-defined hydrophobic iron oxide nanospheres and iron nanocubes of 13 nm size, we have used three methods to increase their hydrophilicity and transfer them into water: surface ligand modification, ligand exchange or encapsulation. The NPs obtained have been characterized by dynamic light scattering and transmission electron microscopy, and the relaxivities of their stable colloidal solutions in water have been determined. Among all samples prepared, iron nanocubes coated by silica display the highest relaxivity (r{sub 2}) value: 628 s{sup −1} mM{sup −1}. - Highlights: • Surface coating effect on the efficiency of iron based nanoparticles (NPs) as MRI contrast agents. • Synthesis of 2 different types of hydrophobic iron based NPs: iron oxide nanospheres and iron nanocubes (13 nm). • Development of three different procedures to stabilize iron based NPs in water. • Iron nanocubes coated by silica displayed the highest r{sub 2} value (628 s{sup −1} mM{sup −1})

  20. Biocompatible astaxanthin as novel contrast agent for biomedical imaging.

    Science.gov (United States)

    Nguyen, Van Phuc; Park, Suhyun; Oh, Junghwan; Wook Kang, Hyun

    2017-08-01

    Photoacoustic imaging (PAI) is a hybrid imaging modality with high resolution and sensitivity that can be beneficial for cancer staging. Due to insufficient endogenous photoacoustic (PA) contrast, the development of exogenous agents is critical in targeting cancerous tumors. The current study demonstrates the feasibility of marine-oriented material, astaxanthin, as a biocompatible PA contrast agent. Both silicon tubing phantoms and ex vivo bladder tissues are tested at various concentrations (up to 5 mg/ml) of astaxanthin to quantitatively explore variations in PA responses. A Q-switched Nd : YAG laser (λ = 532 nm) in conjunction with a 5 MHz ultrasound transducer is employed to generate and acquire PA signals from the samples. The phantom results presented that the PA signal amplitudes increase linearly with the astaxanthin concentrations (threshold detection = 0.31 mg/ml). The tissue injected with astaxanthin yields up to 16-fold higher PA signals, compared with that with saline. Due to distribution of the injected astaxanthin, PAI can image the margin of astaxanthin boles as well as quantify their volume in 3D reconstruction. Further investigations on selective tumor targeting are required to validate astaxanthin as a potential biocompatible contrast agent for PAI-assisted bladder cancer detection. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Tumor Vessel Compression Hinders Perfusion of Ultrasonographic Contrast Agents1

    Science.gov (United States)

    Galiè, Mirco; D'Onofrio, Mirko; Montani, Maura; Amici, Augusto; Calderan, Laura; Marzola, Pasquina; Benati, Donatella; Merigo, Flavia; Marchini, Cristina; Sbarbati, Andrea

    2005-01-01

    Abstract Contrast-enhanced ultrasound (CEUS) is an advanced approach to in vivo assessment of tumor vascularity and is being increasingly adopted in clinical oncology. It is based on 1- to 10 µm-sized gas microbubbles, which can cross the capillary beds of the lungs and are effective echo enhancers. It is known that high cell density, high transendothelial fluid exchange, and poorly functioning lymphatic circulation all provoke solid stress, which compresses vessels and drastically reduces tumor blood flow. Given their size, we supposed that the perfusion of microbubbles is affected by anatomic features of tumor vessels more than are contrast agents traditionally used in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Here, we compared dynamic information obtained from CEUS and DCE-MRI on two experimental tumor models exhibiting notable differences in vessel anatomy. We found that tumors with small, flattened vessels show a much higher resistance to microbubble perfusion than to MRI contrast agents, and appear scarcely vascularized at CEUS examination, despite vessel volume adequate for normal function. Thus, whereas CEUS alone could induce incorrect diagnosis when tumors have small or collapsed vessels, integrated analysis using CEUS and DCE-MRI allows in vivo identification of tumors with a vascular profile frequently associated with malignant phenotypes. PMID:15967105

  2. MR-angiography: the role of contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Goyen, Mathias; Ruehm, Stefan G.; Debatin, Joerg F. E-mail: debatin@uni-essen.de

    2000-06-01

    Contrast-enhanced 3D MR angiography (MRA) permits comprehensive assessment of the supraaortic arteries as well as the arterial system in the chest, abdomen and lower extremities. 3D MRA combines intravenous injection of a non-nephrotoxic, paramagnetic, extracellular contrast agent that increases the signal intensity of blood by shortening its T1 value with the acquisition of a fast 3D data set. High contrast between the vascular lumen and surrounding tissues, inherent three-dimensionality and the ability to collect image data in the chest and abdomen under apnea conditions all contribute to excellent image quality. This review provides clinical applications of 3D MRA in the chest, abdomen and lower extremities based upon the available literature and several clinical examples.

  3. Biocompatible Nanocomplexes for Molecular Targeted MRI Contrast Agent

    Directory of Open Access Journals (Sweden)

    Yu Dexin

    2009-01-01

    Full Text Available Abstract Accurate diagnosis in early stage is vital for the treatment of Hepatocellular carcinoma. The aim of this study was to investigate the potential of poly lactic acid–polyethylene glycol/gadolinium–diethylenetriamine-pentaacetic acid (PLA–PEG/Gd–DTPA nanocomplexes using as biocompatible molecular magnetic resonance imaging (MRI contrast agent. The PLA–PEG/Gd–DTPA nanocomplexes were obtained using self-assembly nanotechnology by incubation of PLA–PEG nanoparticles and the commercial contrast agent, Gd–DTPA. The physicochemical properties of nanocomplexes were measured by atomic force microscopy and photon correlation spectroscopy. The T1-weighted MR images of the nanocomplexes were obtained in a 3.0 T clinical MR imager. The stability study was carried out in human plasma and the distribution in vivo was investigated in rats. The mean size of the PLA–PEG/Gd–DTPA nanocomplexes was 187.9 ± 2.30 nm, and the polydispersity index was 0.108, and the zeta potential was −12.36 ± 3.58 mV. The results of MRI test confirmed that the PLA–PEG/Gd–DTPA nanocomplexes possessed the ability of MRI, and the direct correlation between the MRI imaging intensities and the nano-complex concentrations was observed (r = 0.987. The signal intensity was still stable within 2 h after incubation of the nanocomplexes in human plasma. The nanocomplexes gave much better image contrast effects and longer stagnation time than that of commercial contrast agent in rat liver. A dose of 0.04 mmol of gadolinium per kilogram of body weight was sufficient to increase the MRI imaging intensities in rat livers by five-fold compared with the commercial Gd–DTPA. PLA–PEG/Gd–DTPA nanocomplexes could be prepared easily with small particle sizes. The nanocomplexes had high plasma stability, better image contrast effect, and liver targeting property. These results indicated that the PLA–PEG/Gd–DTPA nanocomplexes might be potential as molecular

  4. Multifunctional photosensitizer-based contrast agents for photoacoustic imaging.

    Science.gov (United States)

    Ho, Chris Jun Hui; Balasundaram, Ghayathri; Driessen, Wouter; McLaren, Ross; Wong, Chi Lok; Dinish, U S; Attia, Amalina Binte Ebrahim; Ntziachristos, Vasilis; Olivo, Malini

    2014-06-18

    Photoacoustic imaging is a novel hybrid imaging modality combining the high spatial resolution of optical imaging with the high penetration depth of ultrasound imaging. Here, for the first time, we evaluate the efficacy of various photosensitizers that are widely used as photodynamic therapeutic (PDT) agents as photoacoustic contrast agents. Photoacoustic imaging of photosensitizers exhibits advantages over fluorescence imaging, which is prone to photobleaching and autofluorescence interference. In this work, we examined the photoacoustic activity of 5 photosensitizers: zinc phthalocyanine, protoporphyrin IX, 2,4-bis [4-(N,N-dibenzylamino)-2,6-dihydroxyphenyl] squaraine, chlorin e6 and methylene blue in phantoms, among which zinc phthalocyanine showed the highest photoacoustic activity. Subsequently, we evaluated its tumor localization efficiency and biodistribution at multiple time points in a murine model using photoacoustic imaging. We observed that the probe localized at the tumor within 10 minutes post injection, reaching peak accumulation around 1 hour and was cleared within 24 hours, thus, demonstrating the potential of photosensitizers as photoacoustic imaging contrast agents in vivo. This means that the known advantages of photosensitizers such as preferential tumor uptake and PDT efficacy can be combined with photoacoustic imaging capabilities to achieve longitudinal monitoring of cancer progression and therapy in vivo.

  5. Multifunctional Photosensitizer-Based Contrast Agents for Photoacoustic Imaging

    Science.gov (United States)

    Ho, Chris Jun Hui; Balasundaram, Ghayathri; Driessen, Wouter; McLaren, Ross; Wong, Chi Lok; Dinish, U. S.; Attia, Amalina Binte Ebrahim; Ntziachristos, Vasilis; Olivo, Malini

    2014-06-01

    Photoacoustic imaging is a novel hybrid imaging modality combining the high spatial resolution of optical imaging with the high penetration depth of ultrasound imaging. Here, for the first time, we evaluate the efficacy of various photosensitizers that are widely used as photodynamic therapeutic (PDT) agents as photoacoustic contrast agents. Photoacoustic imaging of photosensitizers exhibits advantages over fluorescence imaging, which is prone to photobleaching and autofluorescence interference. In this work, we examined the photoacoustic activity of 5 photosensitizers: zinc phthalocyanine, protoporphyrin IX, 2,4-bis [4-(N,N-dibenzylamino)-2,6-dihydroxyphenyl] squaraine, chlorin e6 and methylene blue in phantoms, among which zinc phthalocyanine showed the highest photoacoustic activity. Subsequently, we evaluated its tumor localization efficiency and biodistribution at multiple time points in a murine model using photoacoustic imaging. We observed that the probe localized at the tumor within 10 minutes post injection, reaching peak accumulation around 1 hour and was cleared within 24 hours, thus, demonstrating the potential of photosensitizers as photoacoustic imaging contrast agents in vivo. This means that the known advantages of photosensitizers such as preferential tumor uptake and PDT efficacy can be combined with photoacoustic imaging capabilities to achieve longitudinal monitoring of cancer progression and therapy in vivo.

  6. Sonophore labeled RGD: a targeted contrast agent for optoacoustic imaging.

    Science.gov (United States)

    Haedicke, Katja; Brand, Christian; Omar, Murad; Ntziachristos, Vasilis; Reiner, Thomas; Grimm, Jan

    2017-06-01

    Optoacoustic imaging is a rapidly expanding field for the diagnosis, characterization, and treatment evaluation of cancer. However, the availability of tumor specific exogenous contrast agents is still limited. Here, we report on a small targeted contrast agent for optoacoustic imaging using a black hole quencher ® (BHQ) dye. The sonophore BHQ-1 exhibited strong, concentration-dependent, optoacoustic signals in phantoms, demonstrating its ideal suitability for optoacoustic imaging. After labeling BHQ-1 with cyclic RGD-peptide, BHQ-1-cRGD specifically bound to α v β 3 -integrin expressing glioblastoma cell spheroids in vitro . The excellent optoacoustic properties of BHQ-1-cRGD could furthermore be proven in vivo . Together with this emerging imaging modality, our sonophore labeled small peptide probe offers new possibilities for non-invasive detection of molecular structures with high resolution in vivo and furthers the specificity of optoacoustic imaging. Ultimately, the discovery of tailor-made sonophores might offer new avenues for various molecular optoacoustic imaging applications, similar to what we see with fluorescence imaging.

  7. Repositioning Clofazimine as a Macrophage-Targeting Photoacoustic Contrast Agent.

    Science.gov (United States)

    Keswani, Rahul K; Tian, Chao; Peryea, Tyler; Girish, Gandikota; Wang, Xueding; Rosania, Gus R

    2016-03-22

    Photoacoustic Tomography (PAT) is a deep-tissue imaging modality, with potential clinical applications in the diagnosis of arthritis, cancer and other disease conditions. Here, we identified Clofazimine (CFZ), a red-pigmented dye and anti-inflammatory FDA-approved drug, as a macrophage-targeting photoacoustic (PA) imaging agent. Spectroscopic experiments revealed that CFZ and its various protonated forms yielded optimal PAT signals at wavelengths -450 to 540 nm. CFZ's macrophage-targeting chemical and structural forms were detected with PA microscopy at a high contrast-to-noise ratio (CNR > 22 dB) as well as with macroscopic imaging using synthetic gelatin phantoms. In vivo, natural and synthetic CFZ formulations also demonstrated significant anti-inflammatory activity. Finally, the injection of CFZ was monitored via a real-time ultrasound-photoacoustic (US-PA) dual imaging system in a live animal and clinically relevant human hand model. These results demonstrate an anti-inflammatory drug repurposing strategy, while identifying a new PA contrast agent with potential applications in the diagnosis and treatment of arthritis.

  8. Modified Gadonanotubes as a promising novel MRI contrasting agent.

    Science.gov (United States)

    Jahanbakhsh, Rouzbeh; Atyabi, Fatemeh; Shanehsazzadeh, Saeed; Sobhani, Zahra; Adeli, Mohsen; Dinarvand, Rassoul

    2013-07-01

    Carbon nanotubes (CNTs) are emerging drug and imaging carrier systems which show significant versatility. One of the extraordinary characteristics of CNTs as Magnetic Resonance Imaging (MRI) contrasting agent is the extremely large proton relaxivities when loaded with gadolinium ion (Gdn3+) clusters. In this study equated Gdn3+ clusters were loaded in the sidewall defects of oxidized multiwalled (MW) CNTs. The amount of loaded gadolinium ion into the MWCNTs was quantified by inductively coupled plasma (ICP) method. To improve water solubility and biocompatibility of the system, the complexes were functionalized using diamine-terminated oligomeric poly (ethylene glycol) via a thermal reaction method. Gdn3+ loaded PEGylated oxidized CNTs (Gdn3+@CNTs-PEG) is freely soluble in water and stable in phosphate buffer saline having particle size of about 200 nm. Transmission electron microscopy (TEM) images clearly showed formation of PEGylated CNTs. MRI analysis showed that the prepared solution represents 10% more signal intensity even in half concentration of Gd3+ in comparison with commerciality available contrasting agent Magnevist®. In addition hydrophilic layer of PEG at the surface of CNTs could prepare stealth nanoparticles to escape RES. It was shown that Gdn3+@CNTs-PEG was capable to accumulate in tumors through enhanced permeability and retention effect. Moreover this system has a potential for early detection of diseases or tumors at the initial stages.

  9. Modified Gadonanotubes as a Promising Novel MRI Contrasting Agent

    Directory of Open Access Journals (Sweden)

    Rouzbeh Jahanbakhsh

    2013-07-01

    Full Text Available Background and purpose of the study:Carbon nanotubes (CNTs are emerging drug and imaging carrier systems which show significant versatility. One of the extraordinary characteristics of CNTs as Magnetic Resonance Imaging (MRI contrasting agent is the extremely large proton relaxivities when loaded with gadolinium ion (Gdn3+ clusters.Methods:In this study equated Gdn3+ clusters were loaded in the sidewall defects of oxidized multiwalled (MW CNTs. The amount of loaded gadolinium ion into the MWCNTs was quantified by inductively coupled plasma (ICP method. To improve water solubility and biocompatibility of the system, the complexes were functionalized using diamine-terminated oligomeric poly (ethylene glycol via a thermal reaction method.Results:Gdn3+ loaded PEGylated oxidized CNTs (Gdn3+@CNTs-PEG is freely soluble in water and stable in phosphate buffer saline having particle size of about 200 nm. Transmission electron microscopy (TEM images clearly showed formation of PEGylated CNTs. MRI analysis showed that the prepared solution represents 10% more signal intensity even in half concentration of Gd3+ in comparison with commerciality available contrasting agent Magnevist®. In addition hydrophilic layer of PEG at the surface of CNTs could prepare stealth nanoparticles to escape RES.Conclusion:It was shown that Gdn3+@CNTs-PEG was capable to accumulate in tumors through enhanced permeability and retention effect. Moreover this system has a potential for early detection of diseases or tumors at the initial stages.

  10. Micro-radiography of biological samples with medical contrast agents

    Science.gov (United States)

    Dammer, J.; Weyda, F.; Benes, J.; Sopko, V.; Gelbic, I.

    2013-12-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system.

  11. Sonophore labeled RGD: a targeted contrast agent for optoacoustic imaging

    Directory of Open Access Journals (Sweden)

    Katja Haedicke

    2017-06-01

    Full Text Available Optoacoustic imaging is a rapidly expanding field for the diagnosis, characterization, and treatment evaluation of cancer. However, the availability of tumor specific exogenous contrast agents is still limited. Here, we report on a small targeted contrast agent for optoacoustic imaging using a black hole quencher® (BHQ dye. The sonophore BHQ-1 exhibited strong, concentration-dependent, optoacoustic signals in phantoms, demonstrating its ideal suitability for optoacoustic imaging. After labeling BHQ-1 with cyclic RGD-peptide, BHQ-1-cRGD specifically bound to αvβ3-integrin expressing glioblastoma cell spheroids in vitro. The excellent optoacoustic properties of BHQ-1-cRGD could furthermore be proven in vivo. Together with this emerging imaging modality, our sonophore labeled small peptide probe offers new possibilities for non-invasive detection of molecular structures with high resolution in vivo and furthers the specificity of optoacoustic imaging. Ultimately, the discovery of tailor-made sonophores might offer new avenues for various molecular optoacoustic imaging applications, similar to what we see with fluorescence imaging.

  12. Viscosity of iodinated contrast agents during renal excretion

    Energy Technology Data Exchange (ETDEWEB)

    Jost, Gregor, E-mail: Gregor.Jost@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Lengsfeld, Philipp, E-mail: Philipp.Lengsfeld@bayer.com [Global Medical Affairs Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Lenhard, Diana C., E-mail: Diana.Lenhard@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Pietsch, Hubertus, E-mail: Hubertus.Pietsch@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Huetter, Joachim, E-mail: Joachim.Huetter@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Sieber, Martin A., E-mail: Martin.Sieber@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany)

    2011-11-15

    Objective: Modern iodinated non-ionic contrast agents (CAs) can be classified based on their molecular structure into monomeric and dimeric CAs and have at comparable iodine concentrations a different viscosity and osmolality. During their renal excretion, CAs are concentrated in the renal tubuli which might enhance the viscosity difference between monomeric and dimeric CAs. The viscosity of a CA might have an underestimated importance for renal safety, as suggested by recent publications. In this study, we investigated the viscosities of CAs at the concentrations expected to be present in renal tubules. This concentration process was simulated in vitro using dialysis. Furthermore, we investigated urine viscosity and urine flow in rodents after administration of several non-ionic monomeric and dimeric CAs. Materials and methods: To estimate the viscosity of the CAs in vivo, we performed an in vitro dialysis of monomeric and dimeric CAs at various physiological osmolalities of the renal tubulus (290, 400, 500, 700 and 1000 mOsm/kg H{sub 2}O). Following the dialysis, the iodine concentrations and the viscosities of the CAs were determined. Furthermore, to investigate the concentration process in vivo, we measured the urine viscosity and the urine flow in Han Wister rats after the administration of Iopromide, Iohexol, Ioversol, Iomeprol, Iodixanol, and Iosimenol at comparable iodine concentrations. As a control, saline was injected at the same volume. Results: In vitro dialysis of the dimeric CA increased the iodine concentration and strongly increased the viscosity at all tested osmolalities. In contrast, for the monomeric agents an increase in concentration and viscosity was observed only at 700 as well 1000 mOsm/kg H{sub 2}O but to a lesser extent. In summary, dialysis strongly enhanced the viscosity differences between the non-ionic monomeric and dimeric CAs. The administration of dimeric CAs leads to a strong increase in urine viscosity; this was not observed for

  13. Quinone-fused porphyrins as contrast agents for photoacoustic imaging

    KAUST Repository

    Banala, Srinivas

    2017-06-27

    Photoacoustic (PA) imaging is an emerging non-invasive diagnostic modality with many potential clinical applications in oncology, rheumatology and the cardiovascular field. For this purpose, there is a high demand for exogenous contrast agents with high absorption coefficients in the optical window for tissue imaging, i.e. the near infrared (NIR) range between 680 and 950 nm. We herein report the photoacoustic properties of quinone-fused porphyrins inserted with different transition metals as new highly promising candidates. These dyes exhibit intense NIR absorption, a lack of fluorescence emission, and PA sensitivity in concentrations below 3 nmol mL. In this context, the highest PA signal was obtained with a Zn(ii) inserted dye. Furthermore, this dye was stable in blood serum and free thiol solution and exhibited negligible cell toxicity. Additionally, the Zn(ii) probe could be detected with an up to 3.2 fold higher PA intensity compared to the clinically most commonly used PA agent, ICG. Thus, further exploration of the \\'quinone-fusing\\' approach to other chromophores may be an efficient way to generate highly potent PA agents that do not fluoresce and shift their absorption into the NIR range.

  14. Cellulose nanoparticles: photoacoustic contrast agents that biodegrade to simple sugars

    Science.gov (United States)

    Jokerst, Jesse V.; Bohndiek, Sarah E.; Gambhir, Sanjiv S.

    2014-03-01

    In photoacoustic imaging, nanoparticle contrast agents offer strong signal intensity and long-term stability, but are limited by poor biodistribution and clearance profiles. Conversely, small molecules offer renal clearance, but relatively low photoacoustic signal. Here we describe a cellulose-based nanoparticle with photoacoustic signal superior to gold nanorods, but that undergoes enzymatic cleavage into constituent glucose molecules for renal clearance. Cellulose nanoparticles (CNPs) were synthesized through acidic cleavage of cellulose linters and purified with centrifugation. TEM indicated that the nanoparticles were 132 +/- 46 nm; the polydispersity index was 0.138. Ex vivo characterization showed a photoacoustic limit of detection of 0.02 mg/mL CNPs, and the photoacoustic signal of CNPs was 1.5- to 3.0-fold higher than gold nanorods (also at 700 nm resonance) on a particle-to-particle basis. Cell toxicity assays suggested that overnight doses below 0.31 mg/mL CNPs produced no significant (p>0.05) impact on cell metabolism. Intravenous doses up to 0.24 mg were tolerated well in nude mice. Subcutaneous and orthotopic tumor xenografts of the OV2008 ovarian cancer cell line were then created in nude mice. Data was collected with a Nexus128 scanner from Endra LifeSciences. Spectral data used a LAZR system from Visualsonics both at 700 nm excitation. We injected CNPs (0.024 mg, 0.048 mg, and 0.80 mg) via tail vein and showed that the tumor photoacoustic signal reached maximum increase between 10 and 20 minutes. All injected concentrations were statistically (p0.96 suggesting quantitative signal. CNP biodegradation was demonstrated ex vivo with a glucose assay. CNPs in the presence of cellulase were reduced to free glucose in under than four hours. The glucose concentration before addition of cellulase was not detectable, but increased to 92.1 μg/mL in four hours. CNPs in the absence of cellulase did not produce glucose. Small fragments of nanoparticle in the

  15. Fluorine cardiovascular magnetic resonance angiography in vivo at 1.5 T with perfluorocarbon nanoparticle contrast agents.

    Science.gov (United States)

    Neubauer, Anne M; Caruthers, Shelton D; Hockett, Franklin D; Cyrus, Tillman; Robertson, J David; Allen, J Stacy; Williams, Todd D; Fuhrhop, Ralph W; Lanza, Gregory M; Wickline, Samuel A

    2007-01-01

    While the current gold standard for coronary imaging is X-ray angiography, evidence is accumulating that it may not be the most sensitive technique for detecting unstable plaque. Other imaging modalities, such as cardiovascular magnetic resonance (CMR), can be used for plaque characterization, but suffer from long scan and reconstruction times for determining regions of stenosis. We have developed an intravascular fluorinated contrast agent that can be used for angiography with cardiovascular magnetic resosnace at clinical field strengths (1.5 T). This liquid perfluorocarbon nanoparticle contains a high concentration of fluorine atoms that can be used to generate contrast on 19F MR images without any competing background signal from surrounding tissues. By using a perfluorocarbon with 20 equivalent fluorine molecules, custom-built RF coils, a modified clinical scanner, and an efficient steady-state free procession sequence, we demonstrate the use of this agent for angiography of small vessels in vitro, ex vivo, and in vivo. The surprisingly high signal generated with very short scan times and low doses of perfluorocarbon indicates that this technique may be useful in clinical settings when coupled with advanced imaging strategies.

  16. A model for ultrasound contrast agent in a phantom vessel

    KAUST Repository

    Qamar, Adnan

    2014-02-01

    A theoretical framework to model the dynamics of Ultrasound Contrast Agent (UCA) inside a phantom vessel is presented. The model is derived from the reduced Navier-Stokes equation and is coupled with the evolving flow field solution inside the vessel by a similarity transformation approach. The results are computed, and compared with experiments available in literature, for the initial UCA radius of Ro=1.5 μm and 2 μm for the vessel diameter of D=12 μm and 200 μm with the acoustic parameters as utilized in the experiments. When compared to other models, better agreement on smaller vessel diameter is obtained with the proposed coupled model. The model also predicts, quite accurately, bubble fragmentation in terms of acoustic and geometric parameters. © 2014 IEEE.

  17. Tracers and contrast agents in cardiovascular imaging: present and future

    International Nuclear Information System (INIS)

    Marmion, M.; Deutsch, E.

    1996-01-01

    This brief article addresses the current status and future potential of nuclear medicine, X-ray computed tomography (CT), ultrasound (US), and magnetic resonance (MR) imaging in the diagnosis of cardiovascular diseases. The currently perceived advantages and disadvantages, as well as the possible future roles, of each of the modalities with regard to the evaluation of coronary artery disease are delineated. The certain advent of Mr and US myocardial contrast agents, combined with the inexorable pressures of health care reform, will alter the future usage patterns of all four modalities. Future debates about which modality should be used in which clinical situation will be based not on 'anatomy vs function', nor on the issues of cost effectiveness and patient outcomes

  18. Magnetic susceptibility imaging with a nonionic contrast agent

    International Nuclear Information System (INIS)

    Cacheris, W.; Rocklage, S.M.; Quay, S.; Dow, W.; Love, D.; Worah, D.; Lim, K.

    1988-01-01

    The magnetic susceptibility mechanism for MR imaging contrast enhancement has the advantage of providing useful information, such as cerebral blood flow, without crossing the blood-brain barrier. In this paper the authors report the use of a highly effective, relatively nontoxic chelate as a magnetic susceptibility agent. Dy-DTPA-bis(methylamide) (Dy-DTPA-BMA) has an extremely low acute toxicity (LD-50, intravenous, mice ∼ 40 mmol/kg). Doses of 1 mmol/kg and 2 mmol/kg Dy-DTPA-BMA lowered the initial signal intensity 63% to 57%, respectively. The utility of this technique in detecting areas of reduced blood flow within the brain was demonstrated by imaging a rabbit with a cerebral perfusion deficit

  19. Gadolinium chloride as a contrast agent for imaging wood composite components by magnetic resonance

    Science.gov (United States)

    Thomas L. Eberhardt; Chi-Leung So; Andrea Protti; Po-Wah So

    2009-01-01

    Although paramagnetic contrast agents have an established track record in medical uses of magnetic resonance imaging (MRI), only recently has a contrast agent been used for enhancing MRI images of solid wood specimens. Expanding on this concept, wood veneers were treated with a gadolinium-based contrast agent and used in a model system comprising three-ply plywood...

  20. Utility of a prototype liposomal contrast agent for x-ray imaging of breast cancer: a proof of concept using micro-CT in small animals

    Science.gov (United States)

    Badea, C. T.; Samei, E.; Ghaghada, K.; Saunders, R.; Yuan, H.; Qi, Y.; Hedlund, L. W.; Mukundan, S.

    2008-03-01

    Imaging tumor angiogenesis in small animals is extremely challenging due to the size of the tumor vessels. Consequently, both dedicated small animal imaging systems and specialized intravascular contrast agents are required. The goal of this study was to investigate the use of a liposomal contrast agent for high-resolution micro-CT imaging of breast tumors in small animals. A liposomal blood pool agent encapsulating iodine with a concentration of 65.5 mg/ml was used with a Duke Center for In Vivo Microscopy (CIVM) prototype micro-computed tomography (micro-CT) system to image the R3230AC mammary carcinoma implanted in rats. The animals were injected with equivalent volume doses (0.02 ml/kg) of contrast agent. Micro-CT with the liposomal blood pool contrast agent ensured a signal difference between the blood and the muscle higher than 450 HU allowing the visualization of the tumors 3D vascular architecture in exquisite detail at 100-micron resolution. The micro-CT data correlated well with the histological examination of tumor tissue. We also studied the ability to detect vascular enhancement with limited angle based reconstruction, i.e. tomosynthesis. Tumor volumes and their regional vascular percentage were estimated. This imaging approach could be used to better understand tumor angiogenesis and be the basis for evaluating anti-angiogenic therapies.

  1. Apparition of iodinated contrast agents in twin neonatal gastrointestinal tracts after maternal contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Kato, Hiroki; Kanematsu, Masayuki; Kato, Zenichiro; Kondo, Naomi; Orii, Kenji E.; Morimoto, Masahiro

    2011-01-01

    We describe a case of the appearance of iodinated contrast agents in the same locations of twins' neonatal gastrointestinal tracts 1 day after maternal contrast-enhanced computed tomography (CT). The CT examination had been performed on the expectant mother for suspected deep venous thrombosis on the day previous to the twin delivery. At 23 h after the CT examination and after cesarean section, iodinated contrast agents appeared in the same place in the twins' neonatal gastrointestinal tracts, mainly in the ascending colon, on plain abdominal radiographs. Radiologists, obstetricians, and pediatricians should understand the mechanism of appearance of iodinated contrast agents in fetal gastrointestinal tracts when the expectant mother had been given iodinated contrast agents intravenously shortly before delivery. (author)

  2. Erythrocytes as Carriers for Drugs and Contrast Agents

    Directory of Open Access Journals (Sweden)

    Mauro Magnani

    2014-01-01

    of new biomimetic constructs that now permits the use of these nanomaterials in vivo avoiding their rapid sequestration and their accumulation in unwanted districts (PCT WO 2008/003524 A3. Similarly, the encapsulation of infrared fluorescent agents into RBC gives opportunity to the measurement of vasomotion in the human retinal vasculature suggesting a possible correlation with retinal edema. In summary, the newly developed RBC-based drug delivery system is an innovative technology platform that could be used in a wide range of applications opening to unlimited new therapeutic approaches. Furthermore, the same system has been adapted to deliver contrasting agents within the body enabling the improvement of current fluorangiographic procedures and the imaging by Magnetic Resonance (MRI and Magnetic Particle (MPI. EryDel S.p.A. has recently completed trials to bring EryDex treatment to the market and to implement the clinical applications of the RBC technology.

  3. Ultrasound imaging and contrast agents: a safe alternative to MRI?

    NARCIS (Netherlands)

    Wink, Margot H.; Wijkstra, Hessel; de La Rosette, Jean J. M. C. H.; Grimbergen, Cornelis A.

    2006-01-01

    Microbubble contrast media are used to enhance ultrasound images. Because ultrasound is a real-time investigation, contrast-enhanced ultrasound offers possibilities for perfusion imaging. This review is conducted to evaluate the safety of contrast-enhanced ultrasound and its possible role in medical

  4. The use of new contrast media agents in radiology

    International Nuclear Information System (INIS)

    Zerbe, M.

    1992-01-01

    The purpose of the document is to present the importance of different categories of contrast media in radiography. Ionic and non-ionic contrast media are presented. Pharmacology and pathophysiology of Iodine contrast media with their effects on special organs of the body like the heart, vessels, lungs and nervous systems are explained. Paramagnetic contrast media used in NMR imaging are presented too. Emphasis is made on contrast media based on Gadolinium like Gd-DTPA, Gd-CL3, Gd-EDTA. Actions of Gd-DTPA applied to images in urography are pointed out

  5. Contrast enhancement by differently sized paramagnetic MRI contrast agents in mice with two phenotypes of atherosclerotic plaque

    NARCIS (Netherlands)

    van Bochove, Glenda S.; Paulis, Leonie E. M.; Segers, Dolf; Mulder, Willem J. M.; Krams, Rob; Nicolay, Klaas; Strijkers, Gustav J.

    2011-01-01

    Interest in the use of contrast-enhanced MRI to enable in vivo specific characterization of atherosclerotic plaques is increasing. In this study the intrinsic ability of three differently sized gadolinium-based contrast agents to permeate different mouse plaque phenotypes was evaluated with MRI. A

  6. Ultrasonic microbubble contrast agents and the transplant kidney

    Energy Technology Data Exchange (ETDEWEB)

    Kay, D.H., E-mail: davidhkay@doctors.org.u [Department of Radiology, Western Infirmary, Glasgow (United Kingdom); Mazonakis, M.; Geddes, C. [Department of Renal Medicine, Western Infirmary, Glasgow (United Kingdom); Baxter, G. [Department of Radiology, Western Infirmary, Glasgow (United Kingdom)

    2009-11-15

    Aim: To evaluate the potential application of microbubble agents in the immediate post-transplant period, by studying contrast uptake and washout, and to correlate these values with clinical indices, and thus, assess the potential prognostic value of this technique. Materials and methods: The study group comprised 20 consecutive renal transplant patients within 7 days of transplantation. Sonovue was administered as an intravenous bolus with continuous imaging of the transplant kidney at low mechanical index (MI) for 1 min post-injection. These data were analysed off-line by two observers, and time intensity curves (TIC) for the upper, mid, and lower poles constructed. Within each pole, a region of interest (5 mm square) was placed over the cortex, medullary pyramid, and interlobar artery, resulting in a total of nine TIC for each patient. TIC parameters included the arrival time (AT), time to peak (TTP), peak intensity (Max), gradient of the slope (M), and the area under curve (AUC). Results: For both observers there was good agreement for all values measured from the cortex and medulla, but poor interobserver correlation for the vascular values. In addition, there was only agreement for these values in the upper and mid-pole of the transplant with poor agreement for the lower pole values. The mid-pole of the transplant kidney was chosen as the point of measurement for subsequent studies. Mid-pole values were correlated with clinical data and outcome over the 3-month post-transplant period. Renal microbubble perfusion correlated with the transplant estimated glomerular filtration rate (eGFR) at 3 months post-transplantation (p = 0.016). Discussion: In conclusion, this is the first study to confirm reproducibility of the Sonovue TIC data in transplant patients and to quantify regional variation and perfusion. The statistically significant estimates of transplant perfusion may be of future benefit to transplant recipients and potentially utilized as a prognostic tool

  7. Ultrasonic microbubble contrast agents and the transplant kidney

    International Nuclear Information System (INIS)

    Kay, D.H.; Mazonakis, M.; Geddes, C.; Baxter, G.

    2009-01-01

    Aim: To evaluate the potential application of microbubble agents in the immediate post-transplant period, by studying contrast uptake and washout, and to correlate these values with clinical indices, and thus, assess the potential prognostic value of this technique. Materials and methods: The study group comprised 20 consecutive renal transplant patients within 7 days of transplantation. Sonovue was administered as an intravenous bolus with continuous imaging of the transplant kidney at low mechanical index (MI) for 1 min post-injection. These data were analysed off-line by two observers, and time intensity curves (TIC) for the upper, mid, and lower poles constructed. Within each pole, a region of interest (5 mm square) was placed over the cortex, medullary pyramid, and interlobar artery, resulting in a total of nine TIC for each patient. TIC parameters included the arrival time (AT), time to peak (TTP), peak intensity (Max), gradient of the slope (M), and the area under curve (AUC). Results: For both observers there was good agreement for all values measured from the cortex and medulla, but poor interobserver correlation for the vascular values. In addition, there was only agreement for these values in the upper and mid-pole of the transplant with poor agreement for the lower pole values. The mid-pole of the transplant kidney was chosen as the point of measurement for subsequent studies. Mid-pole values were correlated with clinical data and outcome over the 3-month post-transplant period. Renal microbubble perfusion correlated with the transplant estimated glomerular filtration rate (eGFR) at 3 months post-transplantation (p = 0.016). Discussion: In conclusion, this is the first study to confirm reproducibility of the Sonovue TIC data in transplant patients and to quantify regional variation and perfusion. The statistically significant estimates of transplant perfusion may be of future benefit to transplant recipients and potentially utilized as a prognostic tool

  8. Dual-energy micro-CT functional imaging of primary lung cancer in mice using gold and iodine nanoparticle contrast agents: a validation study.

    Science.gov (United States)

    Ashton, Jeffrey R; Clark, Darin P; Moding, Everett J; Ghaghada, Ketan; Kirsch, David G; West, Jennifer L; Badea, Cristian T

    2014-01-01

    To provide additional functional information for tumor characterization, we investigated the use of dual-energy computed tomography for imaging murine lung tumors. Tumor blood volume and vascular permeability were quantified using gold and iodine nanoparticles. This approach was compared with a single contrast agent/single-energy CT method. Ex vivo validation studies were performed to demonstrate the accuracy of in vivo contrast agent quantification by CT. Primary lung tumors were generated in LSL-Kras(G12D); p53(FL/FL) mice. Gold nanoparticles were injected, followed by iodine nanoparticles two days later. The gold accumulated in tumors, while the iodine provided intravascular contrast. Three dual-energy CT scans were performed-two for the single contrast agent method and one for the dual contrast agent method. Gold and iodine concentrations in each scan were calculated using a dual-energy decomposition. For each method, the tumor fractional blood volume was calculated based on iodine concentration, and tumor vascular permeability was estimated based on accumulated gold concentration. For validation, the CT-derived measurements were compared with histology and inductively-coupled plasma optical emission spectroscopy measurements of gold concentrations in tissues. Dual-energy CT enabled in vivo separation of gold and iodine contrast agents and showed uptake of gold nanoparticles in the spleen, liver, and tumors. The tumor fractional blood volume measurements determined from the two imaging methods were in agreement, and a high correlation (R(2) = 0.81) was found between measured fractional blood volume and histology-derived microvascular density. Vascular permeability measurements obtained from the two imaging methods agreed well with ex vivo measurements. Dual-energy CT using two types of nanoparticles is equivalent to the single nanoparticle method, but allows for measurement of fractional blood volume and permeability with a single scan. As confirmed by ex

  9. Intravenous carbon dioxide as an echocardiographic contrast agent

    NARCIS (Netherlands)

    R.S. Meltzer (Richard); P.W.J.C. Serruys (Patrick); P.G. Hugenholtz (Paul); J.R.T.C. Roelandt (Jos)

    1981-01-01

    textabstractIntravenous carbon dioxide (CO2) was employed to cause echocardiographic contrast in 40 patients. One to 3 cc of medically pure CO2 were agitated with 5 to 8 cc of 5% dextrose in water and rapidly injected into an upper extremity vein. Contrast was obtained in all patients. In 33

  10. Comparison of differently viscous iodinated and bariumcontaining contrast agents in the detection of pharyngeal perforation

    International Nuclear Information System (INIS)

    Keberle, M.; Wittenberg, G.; Trusen, A.; Hahn, D.; Baumgartner, W.

    2001-01-01

    Purpose: In contrast to esophageal perforations, the more radiopaque barium-suspensions are not as important as iodinated aqueous contrast agents for the detection of pharyngeal perforations. This study was performed to find out whether the highly different viscosities (of iodinated and barium-containing contrast agents with comparable radiopacities) are a reason for this. Methods: Viscosity, subjective difference in contrast, and CT-density of an iodinated aqueous (Telebrix) and a 50 wt/vol% barium-containing contrast agent (Micropaque) were determined. Moreover, to exclude postoperative perforation, 104 patients were prospectively examined by pharyngography using both contrast media. Pharyngographies of patients with perforation were later compared by two independent readers. All patients with perforation were followed up clinically to exclude complications due to barium administration. Results: In-vitro comparison showed comparable radiopacity but the 50 wt/vol% barium-suspension was much more viscous that the iodinated contrast agent. During pharyngography, totally, 14 perforations were clearly delineated with the iodinated aqueous contrast agent. However, two of them were not detected with the barium-suspension. All the other perforations presented equally. Conclusions: Given a sufficient radiopacity, a low viscosity appears to be essential for a contrast agent to detect especially pharyngeal perforations. Thus, we recommend the sole use of an iodinated contrast agent (at suspicion of aspiration as isoosmolar variant) for this purpose. (orig.) [de

  11. Engineering of Nanoscale Contrast Agents for Optical Coherence Tomography.

    Science.gov (United States)

    Gordon, Andrew Y; Jayagopal, Ashwath

    2014-01-30

    Optical coherence tomography has emerged as valuable imaging modalityin ophthalmology and other fields by enabling high-resolution three-dimensional imaging of tissue. In this paper, we review recent progress in the field of contrast-enhanced optical coherence tomography (OCT). We discuss exogenous and endogenous sources of OCT contrast, focusing on their use with standard OCT systems as well as emerging OCT-based imaging modalities. We include advances in the processing of OCT data that generate improved tissue contrast, including spectroscopic OCT (SOCT), as well as work utilizing secondary light sources and/or detection mechanisms to create and detect enhanced contrast, including photothermal OCT (PTOCT) and photoacoustic OCT (PAOCT). Finally, we conclude with a discussion of the translational potential of these developments as well as barriers to their clinical use.

  12. Engineering of Nanoscale Contrast Agents for Optical Coherence Tomography

    OpenAIRE

    Gordon, Andrew Y; Jayagopal, Ashwath

    2014-01-01

    Optical coherence tomography has emerged as valuable imaging modalityin ophthalmology and other fields by enabling high-resolution three-dimensional imaging of tissue. In this paper, we review recent progress in the field of contrast-enhanced optical coherence tomography (OCT). We discuss exogenous and endogenous sources of OCT contrast, focusing on their use with standard OCT systems as well as emerging OCT-based imaging modalities. We include advances in the processing of OCT data that gene...

  13. Prevention of radiographic-contrast-agent-induced reductions in renal function by acetylcysteine

    DEFF Research Database (Denmark)

    Tepel, Martin; van der Giet, M; Schwarzfeld, C

    2000-01-01

    Radiographic contrast agents can cause a reduction in renal function that may be due to reactive oxygen species. Whether the reduction can be prevented by the administration of antioxidants is unknown.......Radiographic contrast agents can cause a reduction in renal function that may be due to reactive oxygen species. Whether the reduction can be prevented by the administration of antioxidants is unknown....

  14. An experimental study on tissue reaction of various contrast agents on endometrium, tuber mucosa, and peritoneum

    International Nuclear Information System (INIS)

    Kim, Jae Seung; Kim, Seung Hyup; Park, In Ae; Park, Jae Hyung; Yoon, Dae Young; Yeon, Kyung Mo

    1994-01-01

    To compare the tissue reactions of various water-soluble and oil-based contrast agents on the endometrium, salpingeal mumosa, and peritoneum. Thirty-three rabbits were used for evaluating the histologic reactions of uterine endometrium, salpinx, and peritoneum. Hysterosalpingography(HSG) was underwent in these rabbits by used Lipiodol, Hexabrix, Rayvist. Ultravist-300, Ultravist-370, and normal saline. Pathologic results were obtained in each of the six groups from the uterine endometrium, salpingeal mucosa, and peritoneum without knowledge of the contrast agent used and time interval from HSG. Mild inflammations were observed in the endometrium, salpingeal mucosa, and peritoneum during the first week of HSG in all rabbits in which water-soluble contrast agents were used. Although there was no significant difference in the degree of inflammation among the groups using various contrast agents, the group with oil-based contrast agent(Lipiodol) showed delayed absorption of contrast agent in the peritoneum, frequent intravasation, fat granuloma, peritoneal adhesion, or uterine infarction. Our results suggest that water-soluble contrast agents can be used safely for HSG, but the use of oil-based contrast agent is questional in safety and should be avoid in patients with tubal obstruction, salpingitis, or endometritis

  15. X-ray spatial frequency heterodyne imaging of protein-based nanobubble contrast agents.

    Science.gov (United States)

    Rand, Danielle; Uchida, Masaki; Douglas, Trevor; Rose-Petruck, Christoph

    2014-09-22

    Spatial Frequency Heterodyne Imaging (SFHI) is a novel x-ray scatter imaging technique that utilizes nanoparticle contrast agents. The enhanced sensitivity of this new technique relative to traditional absorption-based x-ray radiography makes it promising for applications in biomedical and materials imaging. Although previous studies on SFHI have utilized only metal nanoparticle contrast agents, we show that nanomaterials with a much lower electron density are also suitable. We prepared protein-based "nanobubble" contrast agents that are comprised of protein cage architectures filled with gas. Results show that these nanobubbles provide contrast in SFHI comparable to that of gold nanoparticles of similar size.

  16. Optimization of dose and technique for magnetic resonance studies with an oral contrast agent

    International Nuclear Information System (INIS)

    Broglia, L.; Tortora, A.; Maccioni, F.; Arpesani, R.; Marcelli, G.; Ascarelli, A.; Rossi, P.

    1999-01-01

    The aim of the study was to optimize the dose, scan delay and sequences for use in magnetic resonance (MR) studies with an oral contrast agent (FerriSeltz, Bracco Spa, Milan, Italy) to obtain positive or negative contrast enhancement in the bowel lumen. Ferric ammonium citrate, being positive or negative contrast agent according to its dilution, permits to tailor the dose to optimize bowel lumen opacification [it

  17. Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

    Science.gov (United States)

    Yeh, Benjamin M; FitzGerald, Paul F; Edic, Peter M; Lambert, Jack W; Colborn, Robert E; Marino, Michael E; Evans, Paul M; Roberts, Jeannette C; Wang, Zhen J; Wong, Margaret J; Bonitatibus, Peter J

    2017-04-01

    The introduction of spectral CT imaging in the form of fast clinical dual-energy CT enabled contrast material to be differentiated from other radiodense materials, improved lesion detection in contrast-enhanced scans, and changed the way that existing iodine and barium contrast materials are used in clinical practice. More profoundly, spectral CT can differentiate between individual contrast materials that have different reporter elements such that high-resolution CT imaging of multiple contrast agents can be obtained in a single pass of the CT scanner. These spectral CT capabilities would be even more impactful with the development of contrast materials designed to complement the existing clinical iodine- and barium-based agents. New biocompatible high-atomic number contrast materials with different biodistribution and X-ray attenuation properties than existing agents will expand the diagnostic power of spectral CT imaging without penalties in radiation dose or scan time. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Magnetic field perturbation in proton MR imaging - A study of a contrast agent and of distortions due to metallic implants

    International Nuclear Information System (INIS)

    Olsson, M.

    1992-01-01

    Perturbations of the static magnetic field in proton MR imaging (NMR imaging, MRI, MRT) result in image distortion and/or signal loss. An investigation of a superparamagnetic contrast agent for MR imaging has been performed. Magnetite particles were embedded in biodegradable starch spheres with a diameter of one micrometer. Animal experiments showed that the agent was quickly accumulated in the reticulo-endothelial system (RES), causing a decrease in signal intensity in this region. Diffusion within the locally generated magnetic field perturbation is responsible for signal loss in spin-echo images. Furthermore, the magnetic properties of various aneurysm clips were investigated to determine which clips could be used safely in a clinical MR investigation. MR artifacts caused by the metallic clips were studied using a geometric phantom. Non-ferromagnetic clips were concluded to be safe for examinations with medium field (0.3 tesla) MR imaging systems. A comparison study between MR and CT was performed on patients harbouring intracranial, nonferromagnetic aneurysm clips. The artifacts close to the clips were equally serve for MR and CT, but at some distance, the MR images were much less affected than the CT images. Finally, a computer program capable of simulating any realistic MR imaging situation has been developed. Raw data matrices are obtained by solving the Bloch equations. Corrections for intravascular spin behaviour have been implemented together with efficient algorithms. A quantitative investigation of signal displacement and signal loss, caused by small metallic implants, has been performed by computer simulation. An exact expression for the magnetic field outside a homogeneous ellipsoid in an external magnetic field has been derived. Distortions in MR images, caused by perturbing ellipsoids of different shapes and orientations, were studied. (30 refs.) (au)

  19. Intravenous ultrasound contrast agents versus other imaging methods in pediatric patients with neoplastic diseases - a comparison.

    Science.gov (United States)

    Piskunowicz, Maciej; Kosiak, Wojciech; Batko, Tomasz; Adamkiewicz-Drożyńska, Elżbieta; Szarmach, Arkadiusz

    2013-12-01

    The lack of registration of ultrasound contrast agents for use in patients below the age of 18 is a significant limitation of their usage. Despite this, examinations with the use of contrast agents are conducted in numerous centers, mainly as part of the diagnostic process of vesicoureteral reflux. Examinations after an intravenous administration of contrast agents are conducted rarely. The reason for this is not only the lack of registration, but also the lack of studies on their safety profile in paediatric patients or no guidelines concerning the dosage. It seems that imaging with the use of such agents could help solve certain clinical problems when other diagnostic methods fail. The paper presents selected cases of pediatric patients treated in oncological departments, in whom the examination with the use of ultrasound contrast agents had a considerable influence on the diagnostic and therapeutic process.

  20. Nanodiamond-Manganese dual mode MRI contrast agents for enhanced liver tumor detection.

    Science.gov (United States)

    Hou, Weixin; Toh, Tan Boon; Abdullah, Lissa Nurrul; Yvonne, Tay Wei Zheng; Lee, Kuan J; Guenther, Ilonka; Chow, Edward Kai-Hua

    2017-04-01

    Contrast agent-enhanced magnetic resonance (MR) imaging is critical for the diagnosis and monitoring of a number of diseases, including cancer. Certain clinical applications, including the detection of liver tumors, rely on both T1 and T2-weighted images even though contrast agent-enhanced MR imaging is not always reliable. Thus, there is a need for improved dual mode contrast agents with enhanced sensitivity. We report the development of a nanodiamond-manganese dual mode contrast agent that enhanced both T1 and T2-weighted MR imaging. Conjugation of manganese to nanodiamonds resulted in improved longitudinal and transverse relaxivity efficacy over unmodified MnCl 2 as well as clinical contrast agents. Following intravenous administration, nanodiamond-manganese complexes outperformed current clinical contrast agents in an orthotopic liver cancer mouse model while also reducing blood serum concentration of toxic free Mn 2+ ions. Thus, nanodiamond-manganese complexes may serve as more effective dual mode MRI contrast agent, particularly in cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Joyce T. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Robinson, Joshua D. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Deng, Jie [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Rigsby, Cynthia K. [Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States)

    2016-12-15

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  2. Synthesis of ultrasound contrast agents: characteristics and size distribution analysis (secondary publication)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hak Jong [Program in Nano Science and Technology, Dept. of Transdisciplinary Studies, Seoul National University Graduate School of Convergence Science and Technology, Seoul (Korea, Republic of); Yoon, Tae Jong [Dept. of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); Yoon, Young Il [Dept. of Applied Bioscience, CHA University, Pocheon (Korea, Republic of)

    2017-10-15

    The purpose of this study was to establish a method for ultrasound (US) contrast agent synthesis and to evaluate the characteristics of the synthesized US contrast agent. A US contrast agent, composed of liposome and sulfur hexafluoride (SF6), was synthesized by dissolving 21 μmol 1,2-dihexadecanoyl-sn-glycero-3-phosphocholine (DPPC, C40H80NO8P), 9 μmol cholesterol, and 1.9 μmol of dihexadecylphosphate (DCP, [CH3(CH2)15O]2P(O)OH) in chloroform. After evaporation in a warm water bath and drying for 12-24 hours, the contrast agent was synthesized using the sonication process by the addition of a buffer and SF6 gas. The size distribution of the bubbles was analyzed using dynamic light scattering measurement methods. The degradation curve was evaluated by assessing the change in the number of contrast agent bubbles using light microscopy immediately, 12, 24, 36, 48, 60, 72, and 84 hours after synthesis. The echogenicity of the synthesized microbubbles was compared with commercially available microbubbles (SonoVue, Bracco). contrast agent was synthesized successfully using an evaporation-drying-sonication method. Most bubbles had a mean diameter of 154.2 nm and showed marked degradation 24 hours after synthesis. Although no statistically significant differences were observed between SonoVue and the synthesized contrast agent, a difference in echogenicity was observed between the synthesized contrast agent and saline (P<0.01). We successfully synthesized a US contrast agent using an evaporation-dryingsonication method. These results may help future research in the fields of anticancer drug delivery, gene delivery, targeted molecular imaging, and targeted therapy.

  3. Synthesis of ultrasound contrast agents: characteristics and size distribution analysis (secondary publication

    Directory of Open Access Journals (Sweden)

    Hak Jong Lee

    2017-10-01

    Full Text Available Purpose The purpose of this study was to establish a method for ultrasound (US contrast agent synthesis and to evaluate the characteristics of the synthesized US contrast agent. Methods A US contrast agent, composed of liposome and sulfur hexafluoride (SF6, was synthesized by dissolving 21 μmol 1,2-dihexadecanoyl-sn-glycero-3-phosphocholine (DPPC, C40H80NO8P, 9 μmol cholesterol, and 1.9 μmol of dihexadecylphosphate (DCP, [CH3(CH215O]2P(OOH in chloroform. After evaporation in a warm water bath and drying for 12-24 hours, the contrast agent was synthesized using the sonication process by the addition of a buffer and SF6 gas. The size distribution of the bubbles was analyzed using dynamic light scattering measurement methods. The degradation curve was evaluated by assessing the change in the number of contrast agent bubbles using light microscopy immediately, 12, 24, 36, 48, 60, 72, and 84 hours after synthesis. The echogenicity of the synthesized microbubbles was compared with commercially available microbubbles (SonoVue, Bracco. Results contrast agent was synthesized successfully using an evaporation-drying-sonication method. Most bubbles had a mean diameter of 154.2 nm and showed marked degradation 24 hours after synthesis. Although no statistically significant differences were observed between SonoVue and the synthesized contrast agent, a difference in echogenicity was observed between the synthesized contrast agent and saline (P<0.01. Conclusion We successfully synthesized a US contrast agent using an evaporation-dryingsonication method. These results may help future research in the fields of anticancer drug delivery, gene delivery, targeted molecular imaging, and targeted therapy.

  4. Motion corrected photoacoustic difference imaging of fluorescent contrast agents

    Science.gov (United States)

    Märk, Julia; Wagener, Asja; Pönick, Sarah; Grötzinger, Carsten; Zhang, Edward; Laufer, Jan

    2016-03-01

    In fluorophores, such as exogenous dyes and genetically expressed proteins, the excited state lifetime can be modulated using pump-probe excitation at wavelengths corresponding to the absorption and fluorescence spectra. Simultaneous pump-probe pulses induce stimulated emission (SE) which, in turn, modulates the thermalized energy, and hence the photoacoustic (PA) signal amplitude. For time-delayed pulses, by contrast, SE is suppressed. Since this is not observed in endogenous chromophores, the location of the fluorophore can be determined by subtracting images acquired using simultaneous and time-delayed pump-probe excitation. This simple experimental approach exploits a fluorophorespecific contrast mechanism, and has the potential to enable deep-tissue molecular imaging at fluences below the MPE. In this study, some of the challenges to its in vivo implementation are addressed. First, the PA signal amplitude generated in fluorophores in vivo is often much smaller than that in blood. Second, tissue motion can give rise to artifacts that correspond to endogenous chromophores in the difference image. This would not allow the unambiguous detection of fluorophores. A method to suppress motion artifacts based on fast switching between simultaneous and time-delayed pump-probe excitation was developed. This enables the acquisition of PA signals using the two excitation modes with minimal time delay (20 ms), thus minimizing the effects of tissue motion. The feasibility of this method is demonstrated by visualizing a fluorophore (Atto680) in tissue phantoms, which were moved during the image acquisition to mimic tissue motion.

  5. Moxifloxacin: Clinically compatible contrast agent for multiphoton imaging

    Science.gov (United States)

    Wang, Taejun; Jang, Won Hyuk; Lee, Seunghun; Yoon, Calvin J.; Lee, Jun Ho; Kim, Bumju; Hwang, Sekyu; Hong, Chun-Pyo; Yoon, Yeoreum; Lee, Gilgu; Le, Viet-Hoan; Bok, Seoyeon; Ahn, G.-One; Lee, Jaewook; Gho, Yong Song; Chung, Euiheon; Kim, Sungjee; Jang, Myoung Ho; Myung, Seung-Jae; Kim, Myoung Joon; So, Peter T. C.; Kim, Ki Hean

    2016-06-01

    Multiphoton microscopy (MPM) is a nonlinear fluorescence microscopic technique widely used for cellular imaging of thick tissues and live animals in biological studies. However, MPM application to human tissues is limited by weak endogenous fluorescence in tissue and cytotoxicity of exogenous probes. Herein, we describe the applications of moxifloxacin, an FDA-approved antibiotic, as a cell-labeling agent for MPM. Moxifloxacin has bright intrinsic multiphoton fluorescence, good tissue penetration and high intracellular concentration. MPM with moxifloxacin was demonstrated in various cell lines, and animal tissues of cornea, skin, small intestine and bladder. Clinical application is promising since imaging based on moxifloxacin labeling could be 10 times faster than imaging based on endogenous fluorescence.

  6. Magnetic nanoparticles as contrast agents for molecular imaging in medicine

    Science.gov (United States)

    O'Donnell, Matthew

    2018-05-01

    For over twenty years, superparamagnetic nanoparticles have been developed for a number of medical applications ranging from bioseparations, magnetic drug targeting, hyperthermia and imaging. Recent studies have shown that they can be functionalized for in vivo biological targeting, potentially enabling nanoagents for molecular imaging and site-localized drug delivery. Here we review several imaging technologies developed using functionalized superparamagnetic iron oxide nanoparticles (SPIONs) as targeted molecular agents. Several imaging modalities have exploited the large induced magnetic moment of SPIONs to create local mechanical force. Magnetic force microscopy can probe nanoparticle uptake in single cells. For in vivo applications, magnetomotive modulation of primary images in ultrasound (US), photoacoustics (PA), and optical coherence tomography (OCT) can help identify very small concentrations of nanoagents while simultaneously suppressing intrinsic background signals from tissue.

  7. Contrasting actions of pressor agents in severe autonomic failure

    Science.gov (United States)

    Jordan, J.; Shannon, J. R.; Biaggioni, I.; Norman, R.; Black, B. K.; Robertson, D.

    1998-01-01

    BACKGROUND: Orthostatic hypotension is the most disabling symptom of autonomic failure. The choice of a pressor agent is largely empiric, and it would be of great value to define predictors of a response. PATIENTS AND METHODS: In 35 patients with severe orthostatic hypotension due to multiple system atrophy or pure autonomic failure, we determined the effect on seated systolic blood pressure (SBP) of placebo, phenylpropanolamine (12.5 mg and 25 mg), yohimbine (5.4 mg), indomethacin (50 mg), ibuprofen (600 mg), caffeine (250 mg), and methylphenidate (5 mg). In a subgroup of patients, we compared the pressor effect of midodrine (5 mg) with the effect of phenylpropanolamine (12.5 mg). RESULTS: There were no significant differences in the pressor responses between patients with multiple system atrophy or pure autonomic failure. When compared with placebo, the pressor response was significant for phenylpropanolamine, yohimbine, and indomethacin. In a subgroup of patients, we confirmed that this pressor effect of phenylpropanolamine, yohimbine, and indomethacin corresponded to a significant increase in standing SBP. The pressor responses to ibuprofen, caffeine, and methylphenidate were not significantly different from placebo. Phenylpropanolamine and midodrine elicited similar pressor responses. There were no significant associations between drug response and autonomic function testing, postprandial hypotension, or plasma catecholamine levels. CONCLUSIONS: We conclude that significant increases in systolic blood pressure can be obtained in patients with orthostatic hypotension due to primary autonomic failure with phenylpropanolamine in low doses or yohimbine or indomethacin in moderate doses. The response to a pressor agent cannot be predicted by autonomic function testing or plasma catecholamines. Therefore, empiric testing with a sequence of medications, based on the risk of side effects in the individual patient and the probability of a response, is a useful approach.

  8. Gadolinium-porphyrins: new potential magnetic resonance imaging contrast agents for melanoma detection

    OpenAIRE

    Daryoush Shahbazi-Gahrouei

    2006-01-01

    BACKGROUND: Two new porphyrin-based magnetic resonance imaging (MRI) contrast agents, Gd-hematoporphyrin (Gd-H) and Gd-tetra-carboranylmethoxyphenyl-porphyrin (Gd-TCP) were synthesized and tested in nude mice with human melanoma (MM-138) xenografts as new melanoma contrast agents. METHODS: Subcutaneous xenografts of human melanoma cells (MM-138) were studied in 30 (five groups of six) nude mice. The effect of different contrast agents (Gd-TCP, Gd-H, GdCl3 and Gd-DTPA) on proton relaxatio...

  9. Comparison of transducers with different frequencies in breast contrast-enhanced ultrasound (CEUS) using SonoVue as contrast agent.

    Science.gov (United States)

    Wang, Yong-Mei; Fan, Wei; Zhang, Kai; Zhang, Li; Tan, Zhen; Ma, Rong

    2016-07-01

    To explore the effectiveness of different transducers in breast contrast-enhanced ultrasound (CEUS) using SonoVue(®) (Bracco, Plan-Les-Ouates, Switzerland) as the contrast agent. Breast CEUS was performed in 51 patients with 51 breast lesions using a low-frequency transducer (probe C5-1) and a high-frequency transducer (probe L12-5) separately. All image processes were reviewed for the presence of local blood perfusion defects and surrounding vessels. McNemar's test was conducted to compare the detection effectiveness between these two transducers. Pathological results revealed 38 malignant and 13 benign lesions. The two transducers showed no difference in detecting benign lesions. Among malignant lesions, CEUS conducted by probe C5-1 (frequency range from 1 to 5 MHz) presented 23 (60.5%) lesions with local blood perfusion defects and 26 (68.4%) lesions with surrounding vessels. Meanwhile, probe L12-5 (frequency range from 5 to 12 MHz) showed only 12 (31.6%) lesions with local blood perfusion defects and 12 (31.6%) lesions with surrounding vessel. Probe C5-1 was more sensitive than probe L12-5 in detecting malignant CEUS characteristics (p-value SonoVue as the contrast agent. A new contrast agent with a higher resonance frequency, specially designed for high-frequency transducers, may be helpful in improving the clinical value of breast CEUS. The first study comparing different frequency transducers in breast CEUS of the same patient lesions. We brought out the requirement for CEUS contrast agents which are more suitable for high-frequency examinations.

  10. Transthoracic contrast echocardiography using vitamin B6 and sodium bicarbonate as contrast agents for the diagnosis of patent foramen ovale.

    Science.gov (United States)

    He, Jiang-Chun; Zheng, Jian-Yong; Li, Xin; Yang, Ye; Zhang, Bo-Yang; Chen, Yu; Li, Xian-Feng; Liu, Ying-Ming; Cao, Yi; Zhao, Li; Li, Tian-Chang

    2017-08-01

    To evaluate the utility of transthoracic contrast echocardiography (cTTE) using vitamin B6 and sodium bicarbonate as contrast agents for diagnosing right-to-left shunt (RLS) caused by patent foramen ovale (PFO) compared to that of transesophageal echocardiography (TEE). We investigated 125 patients admitted to our neurology department with unexplained cerebral infarction and migraine. All patients underwent cTTE using vitamin B6 and sodium bicarbonate as contrast agents, after which they underwent transthoracic echocardiography. The Doppler signal was recorded during the Valsalva maneuver, and TEE examinations were performed. The feasibility, diagnostic sensitivity, and safety of cTTE and TEE for PFO recognition were compared. Evidence of PFO was found in 49 (39.20%) patients with cTTE, more than were detected with TEE (39, 31.20%) (χ 2 =5.0625, P=0.0244). cTTE had a sensitivity of 92.31% and a specificity of 84.88% for diagnosing PFO, showing high concordance with TEE for PFO recognition (κ=0.72). Further, results of a semi-quantitative evaluation of PFO-RLS by cTTE were better than those with TEE (Z=-2.011, P=0.044). No significant adverse reaction was discovered during cTTE examination. cTTE using vitamin B6 and sodium bicarbonate as contrast agents has relatively good sensitivity and specificity for diagnosing RLS caused by PFO when compared with those for TEE. Using vitamin B6 and sodium bicarbonate as contrast agents to perform cTTE is recommended for detecting and diagnosing the PFO due to its simplicity, non-invasive character, low cost, and high feasibility.

  11. Research on a new oral contrast agent for abdominal MRI using free manganese ion

    International Nuclear Information System (INIS)

    Hasegawa, Hideo; Fujita, Osamu; Hiraishi, Kumiko; Narabayashi, Isamu; Komba, Toshinori; Hamamura, Yoshinori.

    1996-01-01

    Manganese chloride (Mn: 3 mg/100 g) aqueous solution with hydragenated oligosaccharide and xanthan gum (T 1 : 0.1 sec, T 2 : 0.03 sec at 0.5T) functions in gut as a positive contrast agent on MR T 1 -weighted images and a low signal component on MR T 2 -weighted images. The manganese in the solution functions as a contrast agent under free manganese ion (Mn 2+ ). Further, the solution has special characteristics in terms of MRI signal intensity and relaxation time that are equal to those of blueberry juice, which performs as an effective contrast agent on T 1 -and T 2 -weighted images, and functions as a contrast agent in vitro and in vivo. (author)

  12. Magnetic resonance contrast media sensing in vivo molecular imaging agents: an overview.

    Science.gov (United States)

    Amanlou, Massoud; Siadat, Seyed Davar; Norouzian, Dariush; Ebrahimi, Seyed Esmaeil Sadat; Aghasadeghi, Mohammad Reza; Ghorbani, Masoud; Alavidjeh, Mohammad Shafiee; Inanlou, Davoud Nouri; Arabzadeh, Ali Jabbari; Ardestani, Mehdi Shafiee

    2011-01-01

    Metabolic imaging is commonly performed by nuclear medicine facilities such as PET or SPECT, etc. The production and biomedical applications of bio-molecular sensing in vivo MRI metabolic contrast agents has recently become of great universal research interest, which follows its great success as a potential cost effective, less radioactive, nuclear medicine alternative. Temperature, redox potential, enzyme activity, free radial/metal ion responsive and/or pH sensitive molecular metabolic MR contrast agents are among the famous instances exemplified, which basically promote MR image contrast enhancement ability to distinguish molecular metabolic/gene expression features. Overall, these MRI contrast agents provide a framework to achieve a greater degree of accuracy from MRI as a low cost, more available facility, non radioactive radiation producing and highly sensitive biomedical tool to propound as a new suggesting opponent for PET nuclear medicine imaging. In the present review, the design, development, examination and future of the above agents will be discussed in detail.

  13. The primary applications of Gd-DTPA as an oral negative gastrointestinal contrast agent for MRCP

    International Nuclear Information System (INIS)

    Chen Yanping; Zhang Xuelin; Cheng Guanxun; Chang Renmin; Zhang Yuzhong; Cang Peng; Xia Qiong

    2003-01-01

    Objective: Using oral Gd-DTPA as a negative contrast agent to null the bowel signal during MR cholangiopancreatography (MRCP) to improve the quality of MRCP. Methods: A phantom study was performed to select the optimal concentration of Gd-DTPA to be used as an oral negative contrast agent in MRCP. 15 patients suspected of biliary tract and pancreatic disease were performed with MRCP before and after using 250 ml oral contrast agents (1:5 diluted Gd-DTPA, 1.488 g/L). All MR images were acquired using a 1.5 T whole body MR scanner (Vision Plus, Siemens). MRCP was acquired using two-dimensional single slice fast spin-echo sequence and HASTE (half-fourier acquisition single-shot fast spin echo) sequence. Results: The phantom study showed that the dilution ratio 1:5 of Gd-DTPA oral contrast agent was best in decreasing the signal intensity both in T 2 WI (59.3%) and in HASTE sequence (82.45%). All the dilution ratio of Gd-DTPA oral contrast agent decreased the signal intensity up to 90% on single slice MRCP. In all the patients the high signal intensity from the stomach and intestinal fluid was completely suppressed. The depictions of common bile duct and pancreatic duct were markedly improved by the oral contrast agent (P<0.05). Conclusion: 1:5 diluted (1.488 g/L) oral MR contrast agent Gd-DTPA can be an effective and safe negative contrast agent in eliminating signal intensity of the gastrointestinal tract, thus improving the depiction of the biliary system in MRCP

  14. Molecular MR Imaging of CD44 in Breast Cancer with Hyaluronan-Based Contrast Agents

    Science.gov (United States)

    2009-09-01

    both Gd groups for MR imaging and cytotoxic moieties can be used as a unique biocompatible platform for theranostic applications in breast cancer ...TITLE: Molecular MR Imaging of CD44 in Breast Cancer with Hyaluronan-Based Contrast Agents PRINCIPAL INVESTIGATOR: Dmitri Artemov, Ph.D...AUG 2009 - 4. TITLE AND SUBTITLE Molecular MR Imaging of CD44 in Breast Cancer with Hyaluronan-Based Contrast Agents 5a. CONTRACT

  15. Ultrasound contrast agent and ultrasound vascular image enhancement system; Choonpa zoeizai oyobi zoei gazo system

    Energy Technology Data Exchange (ETDEWEB)

    Soetanto, K

    1998-09-15

    Ultrasonic diagnosing equipment is effective on the diagnosis of soft tissue inside the body, however, it has a week point in which the ultrasound wave was sheltered by air in hard tissues such as bone and lungs or air in the stomach and intestines. An ultrasound contrast agent was developed to remedy such a basic weak point of ultra wave and to enhance image contrast. As for this contrast agent, several types made of materials such as physiological saline, medicament, gas carbide, and a material containing bubbles have been studied. The most effective one to enhance image contrast among those materials was the ultrasound contrast agent using bubbles. In this paper, the outline of the micro-bubble ultrasound contrast agent was introduced. The week point of the bubble type contrast agent was a short lifetime of bubbles inside blood vessels and the limitation of size and scale. How to overcome the technical problems has become an urgent subject for the development of ultrasound diagnosis. 25 refs., 5 figs.

  16. Polymer Assembly Encapsulation of Lanthanide Nanoparticles as Contrast Agents for In Vivo Micro-CT.

    Science.gov (United States)

    Cruje, Charmainne; Dunmore-Buyze, Joy; MacDonald, Jarret P; Holdsworth, David W; Drangova, Maria; Gillies, Elizabeth R

    2018-03-12

    Despite recent technological advancements in microcomputed tomography (micro-CT) and contrast agent development, preclinical contrast agents are still predominantly iodine-based. Higher contrast can be achieved when using elements with higher atomic numbers, such as lanthanides; lanthanides also have X-ray attenuation properties that are ideal for spectral CT. However, the formulation of lanthanide-based contrast agents at the high concentrations required for vascular imaging presents a significant challenge. In this work, we developed an erbium-based contrast agent that meets micro-CT imaging requirements, which include colloidal stability upon redispersion at high concentrations, evasion of rapid renal clearance, and circulation times of tens of minutes in small animals. Through systematic studies with poly(ethylene glycol) (PEG)-poly(propylene glycol), PEG-polycaprolactone, and PEG-poly(l-lactide) (PLA) block copolymers, the amphiphilic block copolymer PEG 114 -PLA 53 was identified to be ideal for encapsulating oleate-coated lanthanide-based nanoparticles for in vivo intravenous administration. We were able to synthesize a contrast agent containing 100 mg/mL of erbium that could be redispersed into colloidally stable particles in saline after lyophilization. Contrast enhancement of over 250 HU was achieved in the blood pool for up to an hour, thereby meeting the requirements of live animal micro-CT.

  17. Optimized detection and characterization of liver metastases. The role of current MRI contrast agents; Optimierte Detektion und Charakterisierung von Lebermetastasen. Leistungsvermoegen aktueller MRT-Kontrastmittel

    Energy Technology Data Exchange (ETDEWEB)

    Weinrich, J.M.; Well, L.; Bannas, P. [Universitaetsklinikum Hamburg-Eppendorf, Zentrum fuer Radiologie und Endoskopie, Klinik und Poliklinik fuer diagnostische und interventionelle Radiologie und Nuklearmedizin, Hamburg (Germany)

    2017-05-15

    Metastases are the most common malignant lesions of the liver. The presence of liver metastases is an important prognostic factor and is decisive for the further management, especially in patients with colorectal cancer. Detection and characterization of liver metastases as well as differentiation from benign lesions are of high importance and a daily challenge in clinical radiology. Contrast-enhanced magnetic resonance imaging (MRI) has the highest sensitivity in detecting liver metastases. The sensitivity of MRI has been further increased due to the development of liver-specific contrast agents. This article describes the role of extracellular and hepatobiliary contrast agents for the detection and characterization of liver metastases. Moreover, the current knowledge on safety, sequence optimization, transient severe dyspnea and the combination of hepatobiliary with intravascular contrast agents for liver imaging is discussed. (orig.) [German] Metastasen sind die haeufigsten malignen Leberlaesionen. Das Vorhandensein von Lebermetastasen ist entscheidend fuer die Prognose und weitere Therapieplanung von Tumorpatienten, insbesondere von Patienten mit kolorektalen Karzinomen. Die Detektion von Lebermetastasen sowie deren Unterscheidung von anderen Leberlaesionen sind daher von hoechster Bedeutung und stellen eine alltaegliche Herausforderung fuer den Radiologen dar. Die Bildgebung mit der hoechsten Sensitivitaet fuer die Detektion von Lebermetastasen stellt die dynamische kontrastmittelgestuetzte Magnetresonanztomographie (MRT) dar. Die bereits hohe Sensitivitaet der MRT wird durch den Einsatz leberspezifischer Kontrastmittel noch weiter gesteigert. Dieser Artikel beleuchtet die Rolle der aktuellen unspezifischen und leberspezifischen MRT-Kontrastmittel fuer die Detektion und Charakterisierung von Lebermetastasen. Weiterhin werden Erkenntnisse zur Sicherheit, Sequenzoptimierung, zu transienten Atemartefakten und zur Kombination von MRT-Kontrastmitteln fuer die

  18. Topical contrast agents to improve soft-tissue contrast in the upper airway using cone beam CT: a pilot study.

    Science.gov (United States)

    Alsufyani, N A; Noga, M L; Finlay, W H; Major, P W

    2013-01-01

    The purpose of this study is to explore the topical use of radiographic contrast agents to enhance soft-tissue contrast on cone beam CT (CBCT) images. Different barium sulphate concentrations were first tested using an airway phantom. Different methods of barium sulphate application (nasal drops, syringe, spray and sinus wash) were then tested on four volunteers, and nebulized iodine was tested in one volunteer. CBCT images were performed and then assessed subjectively by two examiners for contrast agent uniformity and lack of streak artefact. 25.0% barium sulphate presented adequate viscosity and radiodensity. Barium sulphate administered via nasal drops and sprays showed non-uniform collection at the nostrils, along the inferior and/or middle nasal meatuses and posterior nasal choana. The syringe and sinus wash showed similar results with larger volumes collecting in the naso-oropharynx. Nebulized iodine failed to distribute into the nasal cavity and scarcely collected at the nostrils. All methods of nasal application failed to adequately reach or uniformly coat the nasal cavity beyond the inferior nasal meatuses. The key factors to consider for optimum topical radiographic contrast in the nasal airway are particle size, flow velocity and radio-opacity.

  19. Superparamagnetic Bifunctional Bisphosphonates Nanoparticles: A Potential MRI Contrast Agent for Osteoporosis Therapy and Diagnostic

    Directory of Open Access Journals (Sweden)

    Y. Lalatonne

    2010-01-01

    Full Text Available A bone targeting nanosystem is reported here which combined magnetic contrast agent for Magnetic Resonance Imaging (MRI and a therapeutic agent (bisphosphonates into one drug delivery system. This new targeting nanoplatform consists of superparamagnetic γFe2O3 nanoparticles conjugated to 1,5-dihydroxy-1,5,5-tris-phosphono-pentyl-phosphonic acid (di-HMBPs molecules with a bisphosphonate function at the outer of the nanoparticle surface for bone targeting. The as-synthesized nanoparticles were evaluated as a specific MRI contrast agent by adsorption study onto hydroxyapatite and MRI measurment. The strong adsorption of the bisphosphonates nanoparticles to hydroxyapatite and their use as MRI T2∗ contrast agent were demonstrated. Cellular tests performed on human osteosarcoma cells (MG63 show that γFe2O3@di-HMBP hybrid nanomaterial has no citoxity effect in cell viability and may act as a diagnostic and therapeutic system.

  20. Non-toxic lead sulfide nanodots as efficient contrast agents for visualizing gastrointestinal tract.

    Science.gov (United States)

    Liu, Zhen; Ran, Xiang; Liu, Jianhua; Du, Yingda; Ren, Jinsong; Qu, Xiaogang

    2016-09-01

    Non-invasive imaging of gastrointestinal (GI) tract using novel but efficient contrast agents is of the most important issues in the diagnosis and prognosis of GI diseases. Here, for the first time, we reported the design and synthesis of biothiol-decorated lead sulfide nanodots, as well as their usages in functional dual-modality imaging of GI tract in vivo. Due to the presence of glutathione on the surface of the nanodots, these well-prepared contrast agents could decrease the unwanted ion leakage, withstand the harsh conditions in GI tract, and avoid the systemic absorption after oral administration. Compared with clinical barium meal and iodine-based contrast agents, these nanodots exhibited much more significant enhancement in contrast efficiency during both 2D X-ray imaging and 3D CT imaging. Different from some conventional invasive imaging modalities, such as gastroscope and enteroscope, non-invasive imaging strategy by using glutathione modified PbS nanodots as contrast agents could reduce the painfulness towards patients, facilitate the imaging procedure, and economize the manipulation period. Moreover, long-term toxicity and bio-distribution of these nanodots after oral administration were evaluated in detail, which indicated their overall safety. Based on our present study, these nanodots could act as admirable contrast agents to integrate X-ray imaging and CT imaging for the direct visualization of GI tract. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Erbium-Based Perfusion Contrast Agent for Small-Animal Microvessel Imaging

    Directory of Open Access Journals (Sweden)

    Justin J. Tse

    2017-01-01

    Full Text Available Micro-computed tomography (micro-CT facilitates the visualization and quantification of contrast-enhanced microvessels within intact tissue specimens, but conventional preclinical vascular contrast agents may be inadequate near dense tissue (such as bone. Typical lead-based contrast agents do not exhibit optimal X-ray absorption properties when used with X-ray tube potentials below 90 kilo-electron volts (keV. We have developed a high-atomic number lanthanide (erbium contrast agent, with a K-edge at 57.5 keV. This approach optimizes X-ray absorption in the output spectral band of conventional microfocal spot X-ray tubes. Erbium oxide nanoparticles (nominal diameter 4000 Hounsfield units, and perfusion of vessels < 10 μm in diameter was demonstrated in kidney glomeruli. The described new contrast agent facilitated the visualization and quantification of vessel density and microarchitecture, even adjacent to dense bone. Erbium’s K-edge makes this contrast agent ideally suited for both single- and dual-energy micro-CT, expanding potential preclinical research applications in models of musculoskeletal, oncological, cardiovascular, and neurovascular diseases.

  2. Optimal Contrast Agent Staining of Ligaments and Tendons for X-Ray Computed Tomography.

    Science.gov (United States)

    Balint, Richard; Lowe, Tristan; Shearer, Tom

    2016-01-01

    X-ray computed tomography has become an important tool for studying the microstructures of biological soft tissues, such as ligaments and tendons. Due to the low X-ray attenuation of such tissues, chemical contrast agents are often necessary to enhance contrast during scanning. In this article, the effects of using three different contrast agents--iodine potassium iodide solution, phosphotungstic acid and phosphomolybdic acid--are evaluated and compared. Porcine anterior cruciate ligaments, patellar tendons, medial collateral ligaments and lateral collateral ligaments were used as the basis of the study. Three samples of each of the four ligament/tendon types were each assigned a different contrast agent (giving a total of twelve samples), and the progression of that agent through the tissue was monitored by performing a scan every day for a total period of five days (giving a total of sixty scans). Since the samples were unstained on day one, they had been stained for a total of four days by the time of the final scans. The relative contrast enhancement and tissue deformation were measured. It was observed that the iodine potassium iodide solution penetrated the samples fastest and caused the least sample shrinkage on average (although significant deformation was observed by the time of the final scans), whereas the phosphomolybdic acid caused the greatest sample shrinkage. Equations describing the observed behaviour of the contrast agents, which can be used to predict optimal staining times for ligament and tendon X-ray computed tomography, are presented.

  3. Gadolinium-porphyrins: new potential magnetic resonance imaging contrast agents for melanoma detection

    Directory of Open Access Journals (Sweden)

    Daryoush Shahbazi-Gahrouei

    2006-11-01

    Full Text Available BACKGROUND: Two new porphyrin-based magnetic resonance imaging (MRI contrast agents, Gd-hematoporphyrin (Gd-H and Gd-tetra-carboranylmethoxyphenyl-porphyrin (Gd-TCP were synthesized and tested in nude mice with human melanoma (MM-138 xenografts as new melanoma contrast agents. METHODS: Subcutaneous xenografts of human melanoma cells (MM-138 were studied in 30 (five groups of six nude mice. The effect of different contrast agents (Gd-TCP, Gd-H, GdCl3 and Gd-DTPA on proton relaxation times was measured in tumors and other organs. T1 values, signal enhancement and the Gd concentration for different contrast agent solutions were also investigated. RESULTS: The porphyrin agents showed higher relaxivity compared to the clincal agent, Gd-DTPA. A significant 16% and 21% modification in T1 relaxation time of the water in human melanoma tumors grafted in the nude mice was revealed 24 hours after injection of Gd-TCP and Gd-H, respectively. The percentage of injected Gd localized to the tumor measured by inductively coupled plasma atomic emission spectrometry (ICP-AES was approximately 21% for Gd-TCP and 28% for Gd-H which were higher than that of Gd-DTPA (10%. CONCLUSIONS: The high concentration of Gd in the tumor is indicative of a selective retention of the compounds and indicates that Gd-TCP and Gd-H are promising MR imaging contrast agents for melanoma detection. Gd-porphyrins have considerable promise for further diagnostic applications in magnetic resonance imaging. KEY WORDS: MRI, porphyrin-based contrast agent, hematoporphyrin, melanoma.

  4. Element-specific spectral imaging of multiple contrast agents: a phantom study

    Science.gov (United States)

    Panta, R. K.; Bell, S. T.; Healy, J. L.; Aamir, R.; Bateman, C. J.; Moghiseh, M.; Butler, A. P. H.; Anderson, N. G.

    2018-02-01

    This work demonstrates the feasibility of simultaneous discrimination of multiple contrast agents based on their element-specific and energy-dependent X-ray attenuation properties using a pre-clinical photon-counting spectral CT. We used a photon-counting based pre-clinical spectral CT scanner with four energy thresholds to measure the X-ray attenuation properties of various concentrations of iodine (9, 18 and 36 mg/ml), gadolinium (2, 4 and 8 mg/ml) and gold (2, 4 and 8 mg/ml) based contrast agents, calcium chloride (140 and 280 mg/ml) and water. We evaluated the spectral imaging performances of different energy threshold schemes between 25 to 82 keV at 118 kVp, based on K-factor and signal-to-noise ratio and ranked them. K-factor was defined as the X-ray attenuation in the K-edge containing energy range divided by the X-ray attenuation in the preceding energy range, expressed as a percentage. We evaluated the effectiveness of the optimised energy selection to discriminate all three contrast agents in a phantom of 33 mm diameter. A photon-counting spectral CT using four energy thresholds of 27, 33, 49 and 81 keV at 118 kVp simultaneously discriminated three contrast agents based on iodine, gadolinium and gold at various concentrations using their K-edge and energy-dependent X-ray attenuation features in a single scan. A ranking method to evaluate spectral imaging performance enabled energy thresholds to be optimised to discriminate iodine, gadolinium and gold contrast agents in a single spectral CT scan. Simultaneous discrimination of multiple contrast agents in a single scan is likely to open up new possibilities of improving the accuracy of disease diagnosis by simultaneously imaging multiple bio-markers each labelled with a nano-contrast agent.

  5. EPR and DNP Properties of Certain Novel Single Electron Contrast Agents Intended for Oximetric Imaging

    DEFF Research Database (Denmark)

    Ardenkjær-Larsen, J. H.; Laursen, I; Leunbach, I.

    1998-01-01

    Parameters of relevance to oximetry with Overhauser magnetic resonance imaging (OMRI) have been measured for three single electron contrast agents of the triphenylmethyl type. The single electron contrast agents are stable and water soluble. Magnetic resonance properties of the agents have been...... examined with electron paramagnetic resonance (EPR), nuclear magnetic resonance (NMR), and dynamic nuclear polarization (DNP) at 9.5 mT in water, isotonic saline, plasma, and blood at 23 and 37°C. The relaxivities of the agents are about 0.2–0.4 mM−1s−1and the DNP enhancements extrapolate close...... than 1 μT in water at room temperature. The longitudinal electron spin relaxation rate is calculated from the DNP enhancement curves. The oxygen broadening in water is about 50 μT/mM O2at 37°C. These agents have good properties for oximetry with OMRI....

  6. Use of iohexol as a gastrointestinal contrast agent in three dogs, five cats, and one bird

    International Nuclear Information System (INIS)

    Williams, J.; Biller, D.S.; Myer, C.W.; Miyabayashi, T.; Leveille, R.

    1993-01-01

    Barium sulfate suspension is routinely used as contrast medium for upper gastrointestinal procedures. It has been contraindicated for use in cases of suspected perforation. In such instances, water-soluble iodides are recommended for use. Most of the water-soluble iodides available for use in veterinary medicine at this time are hyperosmolar. This results in in transit dilution of the contrast column. The dilution of the contrast agent within the intestines may prevent visualization of a perforation, especially if the perforation is in the distal portion of the small intestine. Iohexol a nonionic water-soluble iodide of low osmolality, is currently used in veterinary medicine for myelography. We have used it as the contrast agent for upper gastrointestinal studies in cases of suspected obstruction or perforation, with good results, and no adverse effects have been associated with its use. Opacity of the contrast column was adequate, and segmentation or flocculation of the column was not apparent

  7. Biochemical Stability Analysis of Nano Scaled Contrast Agents Used in Biomolecular Imaging Detection of Tumor Cells

    Science.gov (United States)

    Kim, Jennifer; Kyung, Richard

    Imaging contrast agents are materials used to improve the visibility of internal body structures in the imaging process. Many agents that are used for contrast enhancement are now studied empirically and computationally by researchers. Among various imaging techniques, magnetic resonance imaging (MRI) has become a major diagnostic tool in many clinical specialties due to its non-invasive characteristic and its safeness in regards to ionizing radiation exposure. Recently, researchers have prepared aqueous fullerene nanoparticles using electrochemical methods. In this paper, computational simulations of thermodynamic stabilities of nano scaled contrast agents that can be used in biomolecular imaging detection of tumor cells are presented using nanomaterials such as fluorescent functionalized fullerenes. In addition, the stability and safety of different types of contrast agents composed of metal oxide a, b, and c are tested in the imaging process. Through analysis of the computational simulations, the stabilities of the contrast agents, determined by optimized energies of the conformations, are presented. The resulting numerical data are compared. In addition, Density Functional Theory (DFT) is used in order to model the electron properties of the compound.

  8. Investigation of X-ray permeability of surgical gloves coated with different contrast agents

    Science.gov (United States)

    Kayan, Mustafa; Yaşar, Selçuk; Saygın, Mustafa; Yılmaz, Ömer; Aktaş, Aykut Recep; Kayan, Fatmanur; Türker, Yasin; Çetinkaya, Gürsel

    2016-01-01

    Objective: We aimed to investigate the effectiveness and radiation protection capability of latex gloves coated with various contrast agents as an alternative to lead gloves. Methods: The following six groups were created to evaluate the permeability of X-ray in this experimental study: lead gloves, two different non-ionic contrast media (iopromide 370/100 mg I/mL and iomeprol 400/100 mg I/mL), 10% povidone–iodine (PV–I), 240/240 g/mL barium sulphate and a mixture of equal amounts of all contrast agents. A radiation dose detector was placed in coated latex gloves for each one. The absorption values of radiation from latex gloves coated with various contrast agents were measured and compared with the absorption of radiation from lead gloves. This study was designed as an ‘experimental study’. Results: The mean absorption value of X-ray from lead gloves was 3.0±0.08 µG/s. The mean absorption values of X-ray from latex gloves coated with various contrast agents were 3.7±0.09 µG/s (iopromide 370/100 mg I/mL), 3.6±0.09 µG/s (iomeprol 400/100 mg I/mL), 3.7±0.04 µG/s (PV–I), 3.1±0.07 µG/s (barium sulphate) and 3.8±0.05 µG/s (mixture of all contrast agents). Latex gloves coated with barium sulphate provided the best radiation absorption compared with latex gloves coated with other radiodense contrast agents. Conclusion: Latex gloves coated with barium sulphate may provide protection equivalent to lead gloves. PMID:26680548

  9. Contrast agents provide a faster learning curve in dipyridamole stress echocardiography.

    Science.gov (United States)

    Zamorano, Jose; Sánchez, Violeta; Moreno, Raúl; Almería, Carlos; Rodrigo, Jose; Serra, Viviana; Azcona, Luis; Aubele, Adalia; Mataix, Luis; Sánchez-Harguindey, Luis

    2002-12-01

    Interobserver variability is an important limitation of the stress echocardiography and depends on the echocardiographer training. Our aim was to evaluate if the use of contrast agents during dipyridamole stress echocardiography would improve the agreement between an experienced and a non-experienced observer in stress echo and therefore if contrast would affect the learning period of dypyridamole stress echo. Two independent observers without knowledge of any patient data interpreted all stress studies. One observer was an experienced one and the other had experience in echocardiography but not in stress echo. Two observers analysed 87 non-selected and consecutive studies. Out of the 87 studies, 46 were performed without contrast administration, whereas i.v. contrast (2.5 g Levovist by two bolus at rest and at peak stress) was administered in 41. In all cases, second harmonic imaging and stress digitalisation pack was used. The agreement between observers showed a kappa index of 0.58 and 0.83 without and with contrast administration, respectively. The use of contrast agents provides a better agreement in the evaluation of stress echo between an experienced and a non-experienced observer in stress echo. Adding routinely contrast agents could probably reduce the number of exams required for the necessary learning curve in stress echocardiography.

  10. Gd-based macromolecules and nanoparticles as magnetic resonance contrast agents for molecular imaging.

    Science.gov (United States)

    Huang, Ching-Hui; Tsourkas, Andrew

    2013-01-01

    As we move towards an era of personalized medicine, molecular imaging contrast agents are likely to see an increasing presence in routine clinical practice. Magnetic resonance (MR) imaging has garnered particular interest as a platform for molecular imaging applications due its ability to monitor anatomical changes concomitant with physiologic and molecular changes. One promising new direction in the development of MR contrast agents involves the labeling and/or loading of nanoparticles with gadolinium (Gd). These nanoplatforms are capable of carrying large payloads of Gd, thus providing the requisite sensitivity to detect molecular signatures within disease pathologies. In this review, we discuss some of the progress that has recently been made in the development of Gd-based macromolecules and nanoparticles and outline some of the physical and chemical properties that will be important to incorporate into the next generation of contrast agents, including high Gd chelate stability, high "relaxivity per particle" and "relaxivity density", and biodegradability.

  11. Nanoemulsion contrast agents with sub-picomolar sensitivity for xenon NMR.

    Science.gov (United States)

    Stevens, Todd K; Ramirez, R Matthew; Pines, Alexander

    2013-07-03

    A new type of contrast agent for Xe NMR based on surfactant-stabilized perfluorocarbon-in-water nanoemulsions has been produced. The contrast agent uses dissolved hyperpolarized xenon gas as a nonperturbing reporting medium, as xenon freely exchanges between aqueous solution and the perfluorocarbon interior of the droplets, which are spectroscopically distinguishable and allow for chemical exchange saturation transfer (CEST) detection of the agent. Nanoemulsions with droplet diameters between 160 and 310 nm were produced and characterized using hyperpolarized (129)Xe combined with CEST detection. Saturation parameters were varied and data were modeled numerically to determine the xenon exchange dynamics of the system. Nanoemulsion droplets were detected at concentrations as low as 100 fM, corresponding to <1 μL of perfluorocarbon per liter of solution. The straightforward, inexpensive production of these agents will facilitate future development toward molecular imaging and chemical sensing applications.

  12. Polymeric micelles: Theranostic co-delivery system for poorly water-soluble drugs and contrast agents.

    Science.gov (United States)

    Upponi, Jaydev R; Jerajani, Kaushal; Nagesha, Dattatri K; Kulkarni, Praveen; Sridhar, Srinivas; Ferris, Craig; Torchilin, Vladimir P

    2018-03-31

    Interest in theranostic agents has continued to grow because of their promise for simultaneous cancer detection and therapy. A platform-based nanosized combination agent suitable for the enhanced diagnosis and treatment of cancer was prepared using polymeric polyethylene glycol-phosphatidylethanolamine-based micelles loaded with both, poorly soluble chemotherapeutic agent paclitaxel and hydrophobic superparamagnetic iron oxide nanoparticles (SPION), a Magnetic Resonance Imaging contrast agent. The co-loaded paclitaxel and SPION did not affect each other's functional properties in vitro. In vivo, the resulting paclitaxel-SPION-co-loaded PEG-PE micelles retained their Magnetic Resonance contrast properties and apoptotic activity in breast and melanoma tumor mouse models. Such theranostic systems are likely to play a significant role in the combined diagnosis and therapy that leads to a more personalized and effective form of treatment. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Nanoparticles in magnetic resonance imaging: from simple to dual contrast agents

    Directory of Open Access Journals (Sweden)

    Estelrich J

    2015-03-01

    Full Text Available Joan Estelrich,1,2 María Jesús Sánchez-Martín,1 Maria Antònia Busquets1,2 1Departament de Fisicoquímica, Facultat de Farmàcia, Universitat de Barcelona, Barcelona, Catalonia, Spain; 2Institut de Nanociència I Nanotecnologia (IN2UB, Barcelona, Catalonia, SpainAbstract: Magnetic resonance imaging (MRI has become one of the most widely used and powerful tools for noninvasive clinical diagnosis owing to its high degree of soft tissue contrast, spatial resolution, and depth of penetration. MRI signal intensity is related to the relaxation times (T1, spin–lattice relaxation and T2, spin–spin relaxation of in vivo water protons. To increase contrast, various inorganic nanoparticles and complexes (the so-called contrast agents are administered prior to the scanning. Shortening T1 and T2 increases the corresponding relaxation rates, 1/T1 and 1/T2, producing hyperintense and hypointense signals respectively in shorter times. Moreover, the signal-to-noise ratio can be improved with the acquisition of a large number of measurements. The contrast agents used are generally based on either iron oxide nanoparticles or ferrites, providing negative contrast in T2-weighted images; or complexes of lanthanide metals (mostly containing gadolinium ions, providing positive contrast in T1-weighted images. Recently, lanthanide complexes have been immobilized in nanostructured materials in order to develop a new class of contrast agents with functions including blood-pool and organ (or tumor targeting. Meanwhile, to overcome the limitations of individual imaging modalities, multimodal imaging techniques have been developed. An important challenge is to design all-in-one contrast agents that can be detected by multimodal techniques. Magnetoliposomes are efficient multimodal contrast agents. They can simultaneously bear both kinds of contrast and can, furthermore, incorporate targeting ligands and chains of polyethylene glycol to enhance the accumulation of

  14. MRI based on iron oxide nanoparticles contrast agents: effect of oxidation state and architecture

    Science.gov (United States)

    Javed, Yasir; Akhtar, Kanwal; Anwar, Hafeez; Jamil, Yasir

    2017-11-01

    Iron oxide nanoparticles (IONPs) extensively employed beyond regenerative medicines to imaging disciplines because of their great constituents for magneto-responsive nano-systems. The unique superparamagnetic behavior makes IONPs very suitable for hyperthermia and imaging applications. From the last decade, versatile functionalization with surface capabilities, efficient contrast properties and biocompatibilities make IONPs an essential imaging contrast agent for magnetic resonance imaging (MRI). IONPs have shown signals for both longitudinal relaxation and transverse relaxation; therefore, negative contrast as well as dual contrast can be used for imaging in MRI. In the current review, we have focused on different oxidation state of iron oxides, i.e., magnetite, maghemite and hematite for their T1 and T2 contrast enhancement properties. We have also discussed different factors (synthesis protocols, biocompatibility, toxicity, architecture, etc.) that can affect the contrast properties of the IONPs. [Figure not available: see fulltext.

  15. Death associated with bronchography. Question role of heating the contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    McAlister, W.H.

    1989-07-01

    A young woman died following bronchography. The bilateral bronchogram done under general anesthesia without fluoroscopic control was associated with extensive small airway filling or 'alveolarization' of the contrast medium. The oily Dionosil used had been heated in an autoclave. Experiments showed that the viscosity of oily Dionosil decreases with heating. The lowered viscosity could have contributed to the increased 'alveolarization' of the contrast agent and death of the patient. (orig.).

  16. Whole tissue AC susceptibility after superparamagnetic iron oxide contrast agent administration in a rat model

    International Nuclear Information System (INIS)

    Lazaro, Francisco Jose; Gutierrez, Lucia; Rosa Abadia, Ana; Soledad Romero, Maria; Lopez, Antonio; Jesus Munoz, Maria

    2007-01-01

    A magnetic AC susceptibility characterisation of rat tissues after intravenous administration of superparamagnetic iron oxide (Endorem ( R)), at the same dose as established for Magnetic Resonance Imaging (MRI) contrast enhancement in humans, has been carried out. The measurements reveal the presence of the contrast agent as well as that of physiological ferritin in liver and spleen while no traces have been magnetically detected in heart and kidney. This preliminary work opens suggestive possibilities for future biodistribution studies of any type of magnetic carriers

  17. Comparison of voiding cystourethrography and urosonography with second-generation contrast agents in simultaneous prospective study

    Directory of Open Access Journals (Sweden)

    Maciej Piskunowicz

    2016-12-01

    Full Text Available Background: The invasiveness and exposure to radiation in voiding cystourethrography led to the introduction of alternative methods of diagnosis of vesicoureteral reflux, including contrast enhanced voiding urosonography. While there is a limited number of studies comparing these methods using new generation ultrasound contrast agents, none of them compared both methods simultaneously. This study is aimed at assessing agreement between contrast enhanced voiding urosonography with second-generation ultrasound contrast agents and voiding cystourethrography. Methods: From April 2013 to May 2014, 83 children (37 female and 46 male, mean age 3.5 years, age range from 1 month to 17.5 years, underwent prospective simultaneous assessment by contrast enhanced voiding urosonography and voiding cystourethrography, with a total of 166 uretero-renal units evaluated. Results: The sensitivity of voiding cystourethrography and contrast enhanced voiding urosonography were comparable, amounting to 88%, however, neither reached 100% for the entire studied population. The negative predictive value of voiding urosonography and voiding cystourethrography was 97%, and there was no difference between both methods. Conclusion: Voiding cystourethrography and contrast enhanced voiding urosonography are comparable methods in diagnosis of vesicoureteral reflux, and can be performed alternatively. However, some limitations of contrast enhanced voiding urosonography must be remembered.

  18. Fluorescent Method for Observing Intravascular Bonghan Duct

    Directory of Open Access Journals (Sweden)

    Byung-Cheon Lee

    2005-12-01

    Full Text Available Observation of intra-vascular threadlike structures in the blood vessels of rats is reported with the images by differential interference contrast microscope, and fluorescence inverted microscope of the acridine-orange stained samples. The confocal microscope image and the hematoxylin-eosin staining revealed the distinctive pattern of nuclei distribution that clearly discerned the threadlike structure from fibrin, capillary, small venule, arteriole, or lymph vessel. Physiological function of the intra-vascular thread in connection with acupuncture is discussed. Especially, this threadlike duct can be a circulation path for herb-liquid flow, which may provide the scientific mechanism for therapeutic effect of herbal acupuncture.

  19. Iron oxide nanoparticles for use in contrast agents in magnetic resonance imaging; Nanoparticulas de oxido de ferro para uso como agentes de contraste em imagens por ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Elisa M.N. de; Rocha, Maximiliano S. da; Caimi, Priscila de A.; Basso, Nara R. de S.; Zanini, Mara L.; Papaleo, Ricardo M., E-mail: elisa.oliveira@acad.pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil)

    2015-07-01

    In this work were carried out synthesis of iron oxide nanoparticles coated with dextran, comparing the results of using different concentrations of dextran, iron salts, temperature and reaction time. The compounds were analyzed by DLS, XRD, TGA, TEM, FTIR, Zeta Potential and relaxivity. Nanoparticles with dispersion around 10-15 nm and average hydrodynamic diameters of 16-50 nm, with superparamagnetic behavior were obtained. The ratio of the relaxivities (r2/r1) in aqueous solutions was 5.30, close to value of the commercially available iron oxide contrast agents. (author)

  20. Characterization of novel molecular photoacoustic contrast agents for in vivo photoacoustic tomography

    Science.gov (United States)

    Laoui, Samir

    Photoacoustic tomography is a hybrid imaging modality that takes advantage of the high contrast of pure optical imaging and the high intrinsic resolution of ultrasound without the necessity of ionizing radiation. Photoacoustic imaging (PM) is neither purely optical nor purely acoustical in nature, but a combination of the two. It is fundamentally based on light excitation and ultrasonic detection. Photoacoustic imaging has been successful without the introduction of exogenous contrast agents; however, to image deeper regions of biological tissue, a contrast agent is necessary. Several types of photoacoustic contrast agents have been made available for diagnostic purposes; however, the majority of literature has focused on gold nanoparticle systems for which the surface-plasmon resonance effect is important. The only option currently available for molecular PM contrast agents is to choose an existing near infrared absorbing fluorescent probes with the hope that they may generate a substantial photoacoustic (PA) response. However, these dyes have been designed with an optimized fluorescence emission response and are not anticipated to generate an adequate photoacoustic response. This dissertation addresses this lack of precedence in the literature for understanding the mechanism of a photoacoustic signal generation from strongly absorbing dye molecules including BODIPY, cyanine and curcumin systems. This work represents preliminary efforts in bringing novel molecular photoacoustic contrast agents (MPACs) into the photoacoustic imaging arena. To this end, photoacoustic and optical Z-scan experiments, and quenching studies were employed to demonstrate correlation of photoacoustic emission enhancement with excited state absorption mechanisms. To investigate further the photoacoustic emission in a practical imaging setting, MPACs were imaged using a recently developed photoacoustic imaging tomography system which was constructed exclusively for the purpose of this study.

  1. Characterization of a Novel Hafnium-Based X-ray Contrast Agent.

    Science.gov (United States)

    Frenzel, Thomas; Bauser, Marcus; Berger, Markus; Hilger, Christoph Stephan; Hegele-Hartung, Christa; Jost, Gregor; Neis, Christian; Hegetschweiler, Kaspar; Riefke, Björn; Suelzle, Detlev; Pietsch, Hubertus

    2016-12-01

    Characterization of BAY-576, a new x-ray contrast agent which is not based on iodine, but rather on the heavy metal hafnium. Compared with iodine, hafnium provides better x-ray absorption in the energy range of computed tomography (CT) and allows images of comparable quality to be acquired at a significantly reduced radiation dose. A range of standard methods were used to explore the physicochemistry of BAY-576 as well as its tolerability in in vitro assays, its pharmacokinetics and toxicology in rats, and its performance in CT imaging in rabbits. BAY-576 is an extraordinarily stable chelate with a metal content of 42% (wt/wt) and with excellent water solubility. Formulations of 300 mg Hf/mL exhibited viscosity (3.3-3.6 mPa) and osmolality (860-985 mOsm/kg) in the range of nonionic x-ray agents. No relevant effects on erythrocytes, the coagulation, or complement system or on a panel of 87 potential biological targets were observed. The compound did not bind to plasma proteins of a number of species investigated. After intravenous injection in rats, it was excreted fast and mainly via the kidneys. Its pharmacokinetics was comparable to known extracellular contrast agents. A dose of 6000 mg Hf/kg, approximately 10 to 20 times the expected diagnostic dose, was well tolerated by rats with only moderate adverse effects. Computed tomography imaging in rabbits bearing a tumor in the liver demonstrated excellent image quality when compared with iopromide at the same contrast agent dose in angiography during the arterial phase. At 70% of the radiation dose, BAY-576 provided a contrast-to-noise ratio of the tumor, which was equivalent to iopromide at 100% radiation dose. The profile of BAY-576 indicates its potential as the first compound in a new class of noniodine x-ray contrast agents, which can contribute to the reduction of the radiation burden in contrast-enhanced CT imaging.

  2. Impact of contrast agent viscosity on coronary balloon deflation times: bench testing results.

    Science.gov (United States)

    Mogabgab, Owen; Patel, Vishal G; Michael, Tesfaldet T; Kotsia, Anna; Christopoulos, George; Banerjee, Subhash; Brilakis, Emmanouil S

    2014-04-01

    To assess the impact of viscosity on angioplasty balloon deflation times. Lower contrast viscosity could result in more rapid coronary balloon deflation times. We performed a bench comparison of coronary balloon deflation times using 2 contrast agents with different viscosity (ioxaglate and iodixanol), 3 contrast dilutions, and 2 inflation syringe filling volumes. Ten identical pairs of coronary angioplasty balloons were used to conduct each comparison after balloon inflation to 12 atmospheres. Simultaneous deflations were performed under cineangiography. The time to full contrast extraction and the area of contrast remaining after 5 seconds of deflation (quantified by opaque pixel count) were compared between groups. The mean time to full contrast extraction during balloon deflation was 8.3 ± 2.5 seconds for ioxaglate (lower viscosity) versus 10.1 ± 2.9 seconds for iodixanol (higher viscosity) (17.4% decrease, P = 0.005), with a 35.6% (P = 0.004) reduction in contrast area at 5 seconds. Compared to 1:1 ioxaglate-saline mixture, 1:2 and 1:3 ioxaglate/saline mixes resulted in 26.7% (P deflation time, respectively, but at the expense of decreased balloon opacity. Filling the inflation syringe with 5 versus 15 ml of contrast/saline solution was associated with 7.5% decrease in balloon deflation time (P = 0.005), but no difference in contrast area at 5 seconds (P = 0.749). Use of a lower viscosity contrast agent and higher contrast dilution significantly reduced coronary balloon deflation times, whereas use of lower syringe filling volume had a modest effect. Rapid coronary balloon deflation could improve the safety of interventional procedures. © 2014 Wiley Periodicals, Inc.

  3. Measuring SPIO and Gd contrast agent magnetization using 3 T MRI

    Science.gov (United States)

    Cantillon-Murphy, Pádraig; Wald, Lawrence L.; Zahn, Markus; Adalsteinsson, Elfar

    2011-01-01

    Traditional methods of measuring magnetization in magnetic fluid samples, such as vibrating sample magnetometry (VSM), are typically limited to maximum field strengths of about 1 T. This work demonstrates the ability of MRI to measure the magnetization associated with two commercial MRI contrast agents at 3 T by comparing analytical solutions to experimental imaging results for the field pattern associated with agents in cylindrical vials. The results of the VSM and fitted MRI data match closely. The method represents an improvement over VSM measurements since results are attainable at imaging field strengths. The agents investigated are Feridex, a superparamagnetic iron oxide suspension used primarily for liver imaging, and Magnevist, a paramagnetic, gadolinium-based compound used for tumors, inflammation and vascular lesions. MR imaging of the agents took place in sealed cylindrical vials in the presence of a surrounding volume of deionized water where the effects of the contrast agents had a measurable effect on the water's magnetization in the vicinity of the compartment of contrast agent. A pair of phase images were used to reconstruct a B0 fieldmap. The resultant B0 maps in the water region, corrected for shimming and container edge effects, were used to predict the agent's magnetization at 3 T. The results were compared with the results from VSM measurements up to 1.2 T and close correlation was observed. The technique should be of interest to those seeking quantification of the magnetization associated with magnetic suspensions beyond the traditional scope of VSM. The magnetization needs to be sufficiently strong (Ms≳50 Am2/kg Fe for Feridex and χm≳5 × 10−5 m3/kg Gd for Magnevist) for a measurable dipole field in the surrounding water. For this reason, the technique is mostly suitable for undiluted agents. PMID:19588450

  4. Ultrasound contrast agent imaging : Real-time imaging of the superharmonics

    NARCIS (Netherlands)

    Peruzzini, D.; Viti, J.; Tortoli, P.; Verweij, M.D.; De Jong, N.; Vos, H.J.

    2015-01-01

    Currently, in medical ultrasound contrast agent (UCA) imaging the second harmonic scattering of the microbubbles is regularly used. This scattering is in competition with the signal that is caused by nonlinear wave propagation in tissue. It was reported that UCA imaging based on the third or higher

  5. Calix[4]arenes as Molecular Platforms for Magnetic Resonance Imaging (MRI) Contrast Agents

    NARCIS (Netherlands)

    Schehle, Daniel T.; Schatz, Juergen; Laurent, Sophie; Elst, Luce Vander; Muller, Robert N.; Stuart, Marc C. A.; Peters, Joop A.

    2009-01-01

    An amphiphilic conjugate 1 of a calix[4]arene with four Gd-DOTA chelates (DOTA=1,4,7,10-tetra(carboxymethyl)-1,4,7,10-tetraazacyclododecane) was prepared and the properties relevant to its application as a magnetic resonance imaging (MRI) contrast agent were investigated by NMR, dynamic light

  6. Characterization of Definity™ Ultrasound Contrast Agent at Frequency Range of 5–15 MHz

    NARCIS (Netherlands)

    Faez, Telli; Goertz, David; de Jong, N.

    2011-01-01

    The status of vasa vasorum, which can be imaged using ultrasound contrast agents, is an indication for the progression of atherosclerosis. The preferred ultrasound frequency for this purpose is between 5 and 15 MHz. Therefore, it is essential to have knowledge about the acoustic properties of

  7. Contrast Agents for Micro-Computed Tomography of Microdamage in Bone

    National Research Council Canada - National Science Library

    Roeder, Ryan K

    2008-01-01

    ...) and contrast agents with higher x-ray attenuation than bone. The ability to detect the presence and to a limited extent the morphology of microdamage in cortical and trabecular bone using micro-CT was demonstrated using a barium sulfate (BaSO4) stain...

  8. Melanin-Based Contrast Agents for Biomedical Optoacoustic Imaging and Theranostic Applications.

    Science.gov (United States)

    Longo, Dario Livio; Stefania, Rachele; Aime, Silvio; Oraevsky, Alexander

    2017-08-07

    Optoacoustic imaging emerged in early 1990s as a new biomedical imaging technology that generates images by illuminating tissues with short laser pulses and detecting resulting ultrasound waves. This technique takes advantage of the spectroscopic approach to molecular imaging, and delivers high-resolution images in the depth of tissue. Resolution of the optoacoustic imaging is scalable, so that biomedical systems from cellular organelles to large organs can be visualized and, more importantly, characterized based on their optical absorption coefficient, which is proportional to the concentration of absorbing chromophores. Optoacoustic imaging was shown to be useful in both preclinical research using small animal models and in clinical applications. Applications in the field of molecular imaging offer abundant opportunities for the development of highly specific and effective contrast agents for quantitative optoacoustic imaging. Recent efforts are being made in the direction of nontoxic biodegradable contrast agents (such as nanoparticles made of melanin) that are potentially applicable in clinical optoacoustic imaging. In order to increase the efficiency and specificity of contrast agents and probes, they need to be made smart and capable of controlled accumulation in the target cells. This review was written in recognition of the potential breakthroughs in medical optoacoustic imaging that can be enabled by efficient and nontoxic melanin-based optoacoustic contrast agents.

  9. Part 1: MRI features of focal nodular hyperplasia with an emphasis on hepatobiliary contrast agents

    International Nuclear Information System (INIS)

    Sutherland, Tom; Seale, Melanie; Yap, Yap

    2014-01-01

    Focal nodular hyperplasia (FNH) is the second most common benign liver tumour and typically do not require any treatment. An accurate non-invasive diagnosis is therefore vital to avoid unnecessary intervention and to reassure patients. This article discusses the demographics and pathology of FNH and reviews the appearance of FNH at MRI using liver-specific contrast agents.

  10. Clusters of magnetic nanoparticles as contrast agents for MRI: effect of aggregation on transverse relaxivity

    Czech Academy of Sciences Publication Activity Database

    Dědourková, T.; Kaman, Ondřej; Veverka, Pavel; Koktan, Jakub; Veverka, Miroslav; Kuličková, Jarmila; Jirák, Zdeněk; Herynek, V.

    2015-01-01

    Roč. 51, č. 11 (2015), s. 5300804 ISSN 0018-9464 R&D Projects: GA ČR GA15-10088S; GA MPO FR-TI3/521 Institutional support: RVO:68378271 Keywords : contrast agents * magnetic resonance imaging * magnetic nanoparticles * manganites * transverse relaxivity Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.277, year: 2015

  11. Contrast Agents for Micro-Computed Tomography of Microdamage in Bone

    Science.gov (United States)

    2009-01-01

    bone using a barium sulfate contrast agent,” J. Mech. Behav. Biomed. Mater., 1 [1] 68- 75 (2008). Conference Proceedings and Abstracts R.D. Ross and...animals ?N Leng.pdf Ross.pdf Figure1.pdf * Denotes an experimenter who will be on-site at the APS Review Panel:Imaging/ Microbeam Known Safety Hazard ?N

  12. High-relaxivity gadolinium-modified high-density lipoproteins as magnetic resonance imaging contrast agents

    NARCIS (Netherlands)

    Briley-Saebo, Karen C.; Geninatti-Crich, Simonetta; Cormode, David P.; Barazza, Alessandra; Mulder, Willem J. M.; Chen, Wei; Giovenzana, Giovanni B.; Fisher, Edward A.; Aime, Silvio; Fayad, Zahi A.

    2009-01-01

    There is an ongoing desire to produce high-relaxivity, Gd-based magnetic resonance imaging (MRI) contrast agents. These may allow for lower doses to be used, which is especially important in view of the current safety concerns surrounding Gd in patients. Here we report the synthesis of a

  13. Assessment of DNA double-strand breaks induced by intravascular iodinated contrast media following in vitro irradiation and in vivo, during paediatric cardiac catheterization.

    Science.gov (United States)

    Gould, Richard; McFadden, Sonyia L; Horn, Simon; Prise, Kevin M; Doyle, Philip; Hughes, Ciara M

    2016-01-01

    Paediatric cardiac catheterizations may result in the administration of substantial amounts of iodinated contrast media and ionizing radiation. The aim of this work was to investigate the effect of iodinated contrast media in combination with in vitro and in vivo X-ray radiation on lymphocyte DNA. Six concentrations of iodine (15, 17.5, 30, 35, 45, and 52.5 mg of iodine per mL blood) represented volumes of iodinated contrast media used in the clinical setting. Blood obtained from healthy volunteers was mixed with iodinated contrast media and exposed to radiation doses commonly used in paediatric cardiac catheterizations (0 mGy, 70 mGy, 140 mGy, 250 mGy and 450 mGy). Control samples contained no iodine. For in vivo experimentation, pre and post blood samples were collected from children undergoing cardiac catheterization, receiving iodine concentrations of up to 51 mg of iodine per mL blood and radiation doses of up to 400 mGy. Fluorescence microscopy was performed to assess γH2AX-foci induction, which corresponded to the number of DNA double-strand breaks. The presence of iodine in vitro resulted in significant increases of DNA double-strand breaks beyond that induced by radiation for ≥ 17.5 mg/mL iodine to blood. The in vivo effects of contrast media on children undergoing cardiac catheterization resulted in a 19% increase in DNA double-strand breaks in children receiving an average concentration of 19 mg/mL iodine to blood. A larger investigation is required to provide further information of the potential benefit of lowering the amount of iodinated contrast media received during X-ray radiation investigations. Copyright © 2015 John Wiley & Sons, Ltd.

  14. Adverse events caused by MRI contrast agents: Implications for radiographers who inject

    International Nuclear Information System (INIS)

    Marshall, Gill; Kasap, Chris

    2012-01-01

    This article provides a comprehensive literature review regarding side effects both minor and major associated with contrast agent injection. This includes a discussion of nephrogenic systemic fibrosis (NSF), which remains highly topical. Radiographers now commonly are responsible for injection of contrast agent in patients, in keeping with their extended role. Therefore it is incumbent on them to understand the agents they inject, the contra-indications for injection and any potential associated risks, so that they can act and react accordingly in a timely manner. The need for this knowledge was made very evident after the recent death of a patient from anaphylactic shock when there was a delay in mounting the appropriate procedure. This paper represents a synthesis of relevant articles and reflects on the results, before drawing appropriate conclusions particularly those of special relevance to radiographers.

  15. In vivo photoacoustic tumor tomography using a quinoline-annulated porphyrin as NIR molecular contrast agent.

    Science.gov (United States)

    Luciano, Michael; Erfanzadeh, Mohsen; Zhou, Feifei; Zhu, Hua; Bornhütter, Tobias; Röder, Beate; Zhu, Quing; Brückner, Christian

    2017-01-25

    The synthesis and photophysical properties of a tetra-PEG-modified and freely water-soluble quinoline-annulated porphyrin are described. We previously demonstrated the ability of quinoline-annulated porphyrins to act as an in vitro NIR photoacoustic imaging (PAI) contrast agent. The solubility of the quinoline-annulated porphyrin derivative in serum now allowed the assessment of the efficacy of the PEGylated derivative as an in vivo NIR contrast agent for the PAI of an implanted tumor in a mouse model. A multi-fold contrast enhancement when compared to the benchmark dye ICG could be shown, a finding that could be traced to its photophysical properties (short triplet lifetimes, low fluorescence and singlet oxygen sensitization quantum yields). A NIR excitation wavelength of 790 nm could be used, fully taking advantage of the optical window of tissue. Rapid renal clearance of the dye was observed. Its straight-forward synthesis, optical properties with the possibility for further optical fine-tuning, nontoxicity, favorable elimination rates, and contrast enhancement make this a promising PAI contrast agent. The ability to conjugate the PAI chromophore with a fluorescent tag using a facile and general conjugation strategy was also demonstrated.

  16. Novel nano-sized MR contrast agent mediates strong tumor contrast enhancement in an oncogene-driven breast cancer model.

    Directory of Open Access Journals (Sweden)

    Per-Olof Eriksson

    Full Text Available The current study was carried out to test the potential of a new nanomaterial (Spago Pix as a macromolecular magnetic MR contrast agent for tumor detection and to verify the presence of nanomaterial in tumor tissue. Spago Pix, synthesized by Spago Nanomedical AB, is a nanomaterial with a globular shape, an average hydrodynamic diameter of 5 nm, and a relaxivity (r1 of approximately 30 (mM Mn-1 s-1 (60 MHz. The material consists of an organophosphosilane hydrogel with strongly chelated manganese (II ions and a covalently attached PEG surface layer. In vivo MRI of the MMTV-PyMT breast cancer model was performed on a 3 T clinical scanner. Tissues were thereafter analyzed for manganese and silicon content using inductively coupled plasma-atomic emission spectroscopy (ICP-AES. The presence of nanomaterial in tumor and muscle tissue was assessed using an anti-PEG monoclonal antibody. MR imaging of tumor-bearing mice (n = 7 showed a contrast enhancement factor of 1.8 (tumor versus muscle at 30 minutes post-administration. Contrast was retained and further increased 2-4 hours after administration. ICP-AES and immunohistochemistry confirmed selective accumulation of nanomaterial in tumor tissue. A blood pharmacokinetics analysis showed that the concentration of Spago Pix gradually decreased over the first hour, which was in good agreement with the time frame in which the accumulation in tumor occurred. In summary, we demonstrate that Spago Pix selectively enhances MR tumor contrast in a clinically relevant animal model. Based on the generally higher vascular leakiness in malignant compared to benign tissue lesions, Spago Pix has the potential to significantly improve cancer diagnosis and characterization by MRI.

  17. Diagnostic and therapeutic research on ultrasound microbubble/nanobubble contrast agents (Review).

    Science.gov (United States)

    Ma, Jing; Xu, Chang Song; Gao, Feng; Chen, Ming; Li, Fan; Du, Lian Fang

    2015-09-01

    The contrast enhanced imaging function of ultrasound contrast agents (UCAs) has been extensively investigated using physical acoustic signatures. It has a number of novel applications, including tissue‑specific molecular imaging and multi‑modal imaging. In addition there are numerous other therapeutic applications of UCAs, for example as vehicles for drug or gene delivery. These uses are discussed, as well as the acoustically‑induced biological effects, including ultrasound targeted microbubble destruction (UTMD). This review also explores the considerations for the safe use of UCA from an acoustic standpoint. The scope of the application of UCA has markedly expanded in recent years, and it is a rapidly growing field of medical research. The current article reviews recent advances in the diagnostic and therapeutic applications of ultrasound microbubble/nanobubble contrast agents.

  18. Intravascular pulmonary metastases

    International Nuclear Information System (INIS)

    Shepard, J.A.O.; Moore, E.H.; Templeton, P.A.; McLoud, T.C.

    1988-01-01

    The diagnosis of intravascular metastatic tumor emboli to the lungs is rarely made. The authors present a characteristic radiographic finding of intravascular lung metastases that they observed in four patients with diagnoses or right atrial myoxoma, invasive renal cell carcinoma, invasive pelvic osteosarcoma, and recurrent pelvic chondrosarcoma. Substantiation of intravascular pulmonary metastases was achieved by means of autopsy, pulmonary artery biopsy, and surgical documentation of tumor invasion of the inferior vena cava or pelvic veins. In all four cases, chest computed tomography (CT) demonstrated branching, beaded opacities extending from the hila into the periphery of the lung in the distribution of pulmonary arteries. In one case, similar findings were observed in magnetic resonance (MR) images of the chest. Follow-up studies in three cases showed progressive enlargement and varicosity of the abnormal pulmonary artery consistent with proliferation of intravascular tumor. In the case of metastatic osteosarcoma, intraluminal ossification was also observed at CT. In three of four cases, pulmonary infarction was demonstrated in the distribution of the abnormal pulmonary arteries seen at CT as small, peripheral, wedge-shaped opacities. The demonstration of progressively dilated and beaded pulmonary arteries in patients with extrathoracic malignancies is suggestive of intravascular lung metastases, particularly when accompanied by peripheral infarction

  19. An albumin-based gold nanocomposites as potential dual mode CT/MRI contrast agent

    Science.gov (United States)

    Zhao, Wenjing; Chen, Lina; Wang, Zhiming; Huang, Yuankui; Jia, Nengqin

    2018-02-01

    In pursuit of the biological detection applications, recent years have witnessed the prosperity of novel multi-modal nanoprobes. In this study, biocompatible bovine serum albumin (BSA)-coated gold nanoparticles (Au NPs) containing Gd (III) as the contrast agent for both X-ray CT and T1-weighted MR imaging is reported. Firstly, the Au NPs with BSA coating (Au@BSA) was prepared through a moderate one-pot reduction route in the presence of hydrazine hydrate as reducer. Sequentially, the BSA coating enables modification of diethylenetriaminepentaacetic acid (DTPA) as well as targeting reagent hyaluronic acid (HA), and further chelation of Gd (III) ions led to the formation of biomimetic nanoagent HA-targeted Gd-Au NPs (HA-targeted Au@BSA-Gd-DTPA). Several techniques were used to thoroughly characterize the formed HA-targeted Gd-Au NPs. As expected, the as-prepared nanoagent with mean diameter of 13.82 nm exhibits not only good colloid stablility and water dispersibility, but also satisfying low cytotoxicity and hemocompatibility in the tested concentration range. Additionally, for the CT phantoms, the obtained nanocomplex shows an improved contrast in CT scanning than that of Au@BSA as well as small molecule iodine-based CT contrast agents such as iopromide. Meanwhile, for the T1-weighted MRI images, there is a linear increase of contrast with concentration of Gd for the two cases of HA-targeted Gd-Au NPs and Magnevist. Strikingly, the nanoagent we explored displays a relatively higher r1 relaxivity than that of commercial MR contrast agents. Therefore, this newly constructed nanoagent could be used as contrast agents for synergistically enhanced X-ray CT and MR phantoms, holding promising potential for future biomedical applications.

  20. Microbubbles as a scattering contrast agent for grating-based x-ray dark-field imaging.

    Science.gov (United States)

    Velroyen, A; Bech, M; Malecki, A; Tapfer, A; Yaroshenko, A; Ingrisch, M; Cyran, C C; Auweter, S D; Nikolaou, K; Reiser, M; Pfeiffer, F

    2013-02-21

    In clinically established-absorption-based-biomedical x-ray imaging, contrast agents with high atomic numbers (e.g. iodine) are commonly used for contrast enhancement. The development of novel x-ray contrast modalities such as phase contrast and dark-field contrast opens up the possible use of alternative contrast media in x-ray imaging. We investigate using ultrasound contrast agents, which unlike iodine-based contrast agents can also be administered to patients with renal impairment and thyroid dysfunction, for application with a recently developed novel x-ray dark-field imaging modality. To produce contrast from these microbubble-based contrast agents, our method exploits ultra-small-angle coherent x-ray scattering. Such scattering dark-field x-ray images can be obtained with a grating-based x-ray imaging setup, together with refraction-based differential phase-contrast and the conventional attenuation contrast images. In this work we specifically show that ultrasound contrast agents based on microbubbles can be used to produce strongly enhanced dark-field contrast, with superior contrast-to-noise ratio compared to the attenuation signal. We also demonstrate that this method works well with an x-ray tube-based setup and that the relative contrast gain even increases when the pixel size is increased from tenths of microns to clinically compatible detector resolutions about up to a millimetre.

  1. Phenols as Diamagnetic T2-Exchange Magnetic Resonance Imaging Contrast Agents.

    Science.gov (United States)

    Zhang, Jia; Li, Yuguo; Slania, Stephanie; Yadav, Nirbhay N; Liu, Jing; Wang, Rongfu; Zhang, Jianhua; Pomper, Martin G; van Zijl, Peter C; Yang, Xing; Liu, Guanshu

    2018-01-26

    Although T 2 -exchange (T 2ex ) NMR phenomena have been known for decades, there has been a resurgence of interest to develop T 2ex MRI contrast agents. One indispensable advantage of T 2ex MR agents is the possibility of using non-toxic and/or bio-compatible diamagnetic compounds with intermediate exchangeable protons. Herein a library of phenol-based compounds is screened and their T 2ex contrast (exchange relaxivity, r 2ex ) at 9.4 T determined. The T 2ex contrast of phenol protons allows direct detection by MRI at a millimolar concentration level. The effect of chemical modification of the phenol on the T 2ex MRI contrast through modulation of exchange rate and chemical shift was also studied and provides a guideline for use of endogenous and exogenous phenols for T 2ex MRI contrast. As a proof-of-principle application, phenol T 2ex contrast can be used to detect enzyme activity in a tyrosinase-catalyzed catechol oxidation reaction. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Characterization of a murine xenograft model for contrast agent development in breast lesion malignancy assessment.

    Science.gov (United States)

    Yen, Tsung-Hsien; Lee, Gi-Da; Chai, Jyn-Wen; Liao, Jiunn-Wang; Lau, Jia-Yu; Hu, Li-Che; Liao, Kuo-Chih

    2016-05-17

    The aim of the study was to develop a nude mouse xenograft model implanted with both benign and malignant xenografts as the preliminary candidate screening tool for contrast agent development in lesion malignancy indication. A malignant xenograft (either MCF-7 cell/matrigel™ or MDA-MB 231 cell/matrigel) and a benign xenograft (culture medium/matrigel) with cleft and slit-like features of intracanaliculer fibroadenoma were implanted subcutaneously into flanks of individual nu/nu nude mouse with >90 % successful inoculation rate. Both malignant and benign xenografts with volume up to 4 cm(3) and (size up to 2 cm) after 5(th) week were characterized in vivo by sonogram (exhibiting endogenous morphological contrast features between benign and malignant xenografts), dynamic contrast enhanced multi-detector computed tomography (presenting non-targeting exogenous morphological and dynamic contrast features between benign and malignant xenografts), and then were harvested for histological and immunohistochemistry (revealing example of targeting/molecular contrast features, such as expression of cancer vascular markers of malignant xenografts). Malignant xenografts appeared morphologically taller than wide (axis parallel to skin) with angular/ill-defined margin under sonogram observations, revealed more evident rim enhancement, angular margin and washout pattern in the time-density curve from dynamic contrast enhance multi-detector computed tomography images, and had more visible cancer vascular markers (CD31 and VEGF) expression. With limited number of subjects (5-27 for each group of a specific imaging contrast feature), those imaging contrast features of the xenograft model had larger than 85 % sensitivity, specificity, accuracy, positive and negative prediction values in indicating xenograft malignancy except for results from color Doppler detections. The murine xenograft model might provide an earlier efficacy evaluation of new contrast agent candidate for lesion

  3. The use of innovative gadolinium-based contrast agent for MR-diagnosis of cancer in the experiment

    Science.gov (United States)

    Chernov, V.; Medvedeva, A.; Sinilkin, I.; Zelchan, R.; Grigorev, E.; Frolova, I.; Nam, I.

    2016-02-01

    The present study of the functional suitability and specific activity of the contrast agent gadolinium-based for magnetic resonance imaging demonstrated that the investigated contrast agent intensively accumulates in organs and anatomical structures of the experimental animals. In the model of tumor lesions in animals, study have shown that investigational contrast agent accumulates in the tumor tissue and retained there in for a long enough time.

  4. Gd-DTPA: a bowel contrast agent for magnetic resonance imaging of the abdomen

    International Nuclear Information System (INIS)

    Vlahos, L.; Gouliamos, A.; Clauss, W.; Kalovidouris, A.; Hadjiioannou, A.; Athanasopoulou, A.; Trakadas, S.; Papavasiliou, C.

    1992-01-01

    Forty patients with suspected pathology in the abdomen and pelvis have been investigated with MRI before and after administration of Gd-DTPA as an oral or rectal solution. The findings are analysed with respect to: (a) filling of the GI tract; (b) contrast in the region of interest, surrounding fat and vessels; (c) diagnostic yield in comparison to non-enhanced MRI and contrast CT. At a concentration of 1 mmol/l Gd-DTPA provided consistent positive contrast in the stomach and bowel in all cases. In 57.5% of cases we achieved complete filling of the GI tract. The opacification in the region of interest was good or satisfactory in 90% of cases. The diagnostic value of contrast MRI was better in 93% of cases than the non-enhanced MRI of the abdomen. In comparison with contrast CT, the contrast MRI was better or of the same value in 92% of cases. Despite the disadvantage of poor fat-to-bowel contrast (35% of cases were classified as poor), it is concluded that Gd-DTPA-enhanced MRI provides good delineation of organs adjacent to the bowel so this contrast agent has potential for a future role in abdominal MRI. (orig.)

  5. Thermal dependence of ultrasound contrast agents scattering efficiency for echographic imaging techniques

    Science.gov (United States)

    Biagioni, Angelo; Bettucci, Andrea; Passeri, Daniele; Alippi, Adriano

    2015-06-01

    Ultrasound contrast agents are used in echographic imaging techniques to enhance image contrast. In addition, they may represent an interesting solution to the problem of non-invasive temperature monitoring inside the human body, based on some thermal variations of their physical properties. Contrast agents, indeed, are inserted into blood circulation and they reach the most important organs inside the human body; consequently, any thermometric property that they may possess, could be exploited for realizing a non-invasive thermometer. They essentially are a suspension of microbubbles containing a gas enclosed in a phospholipid membrane; temperature variations induce structural modifications of the microbubble phospholipid shell, thus causing thermal dependence of contrast agent's elastic characteristics. In this paper, the acoustic scattering efficiency of a bulk suspension of of SonoVue® (Bracco SpA Milan, Italy) has been studied using a pulse-echo technique in the frequency range 1-17 MHz, as it depends upon temperatures between 25 and 65°C. Experimental data confirm that the ultrasonic attenuation coefficient of SonoVue® depends on temperature between 25 and 60°C. Chemical composition of the bubble shell seem to support the hypothesis that a phase transition in the microstructure of lipid-coated microbubbles could play a key role in explaining such effect.

  6. Gold nanoparticles as a contrast agent for in vivo tumor imaging with photoacoustic tomography

    International Nuclear Information System (INIS)

    Zhang, Q; Jiang, H; Iwakuma, N; Grobmyer, S R; Sharma, P; Moudgil, B M; Wu, C; McNeill, J

    2009-01-01

    Photoacoustic tomography (PAT) is a rapidly emerging non-invasive imaging technology that integrates the merits of high optical contrast with high ultrasound resolution. The ability to quantitatively and non-invasively image nanoparticles has important implications for the development of nanoparticles as in vivo cancer diagnostic and therapeutic agents. In this study, the ability of systemically administered poly(ethylene glycol)-coated (PEGylated) gold nanoparticles as a contrast agent for in vivo tumor imaging with PAT has been evaluated. We demonstrate that gold nanoparticles (20 and 50 nm) have high photoacoustic contrast as compared to mouse tissue ex vivo. Gold nanoparticles can be visualized in mice in vivo following subcutaneous administration using PAT. Following intravenous administration of PEGylated gold nanoparticles to tumor-bearing mice, accumulation of gold nanoparticles in tumors can be effectively imaged with PAT. With gold nanoparticles as a contrast agent, PAT has important potential applications in the image guided therapy of superficial tumors such as breast cancer, melanoma and Merkel cell carcinoma.

  7. Photoacoustic/ultrasound dual-modality contrast agent and its application to thermotherapy

    Science.gov (United States)

    Wang, Yu-Hsin; Liao, Ai-Ho; Chen, Jui-Hao; Chris Wang, Churng-Ren; Li, Pai-Chi

    2012-04-01

    This study investigates a photoacoustic/ultrasound dual-modality contrast agent, including extending its applications from image-contrast enhancement to combined diagnosis and therapy with site-specific targeting. The contrast agent comprises albumin-shelled microbubbles with encapsulated gold nanorods (AuMBs). The gas-filled microbubbles, whose diameters range from submicrometer to several micrometers, are not only echogenic but also can serve as drug-delivery vehicles. The gold nanorods are used to enhance the generation of both photoacoustic and photothermal signals. The optical absorption peak of the gold nanorods is tuned to 760 nm and is invariant after microbubble encapsulation. Dual-modality contrast enhancement is first described here, and the applications to cellular targeting and laser-induced thermotherapy in a phantom are demonstrated. Photoacoustic imaging can be used to monitor temperature increases during the treatment. The targeting capability of AuMBs was verified, and the temperature increased by 26°C for a laser power of 980 mW, demonstrating the potential of combined diagnosis and therapy with the dual-modality agent. Targeted photo- or acoustic-mediated delivery is also possible.

  8. Complications from the use of intravenous gadolinium-based contrast agents for magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Elias Junior, Jorge; Santos, Antonio Carlos dos; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Koenigkam-Santos, Marcel [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas. Centro de Ciencias das Imagens e Fisica Medica]. E-mail: jejunior@fmrp.usp.br

    2008-07-15

    Gadolinium-based contrast agents are much safer than the iodinated ones; however complications may occur and should be recognized for appropriate orientation and management. The total incidence of adverse reactions to contrast agents in magnetic resonance imaging ranges between 2% and 4%. Cases of severe acute reactions to gadolinium, such as laryngospasm and anaphylactic shock, are rare. Chronic complications secondary to the use of gadolinium also can occur and, recently an association between its use and a rare dermatologic disease occurring in patients with renal failure has been reported. Nephrogenic systemic fibrosis was the subject of an official health notification issued by the American Food and Drug Administration. This progressive disease is characterized by hardened skin with fibrotic nodules and plaques which may involve other parts of the body. Patients who have been affected by this disorder presented chronic renal failure, with metabolic acidosis and had been submitted to magnetic resonance angiography, probably involving exposure to large amounts of intravenous paramagnetic contrast. This review is aimed at presenting a succinct description of the gadolinium-based contrast agent types, possible secondary complications, their preventive measures and management. (author)

  9. Colloidal dispersions of maghemite nanoparticles produced by laser pyrolysis with application as NMR contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Veintemillas-Verdaguer, Sabino [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Morales, Maria del Puerto [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Bomati-Miguel, Oscar [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Bautista, Carmen [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Zhao, Xinqing [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Bonville, Pierre [CEA, CE Saclay, DSM/DRECAM/SPEC, 91191 Gif-Sur-Yvette (France); Alejo, Rigoberto Perez de [Universidad Complutense de Madrid, Unidad de RMN, Paseo Juan XXIII, 1, 28040 Madrid (Spain); Ruiz-Cabello, Jesus [Universidad Complutense de Madrid, Unidad de RMN, Paseo Juan XXIII, 1, 28040 Madrid (Spain); Santos, Martin [Hospital Universitario Puerta de Hierro, Servicio de Cirugia Experimental. C/San Martin de Porres 4, 28035 Madrid (Spain); Tendillo-Cortijo, Francisco J [Hospital Universitario Puerta de Hierro, Servicio de Cirugia Experimental. C/San Martin de Porres 4, 28035 Madrid (Spain); Ferreiros, Joaquin [Hospital Clinico de Madrid ' San Carlos' , Ciudad Universitaria, 28040 Madrid (Spain)

    2004-08-07

    Biocompatible magnetic dispersions have been prepared from {gamma}-Fe{sub 2}O{sub 3} nanoparticles (5 nm) synthesized by continuous laser pyrolysis of Fe(CO){sub 5} vapours. The feasibility of using these dispersions as magnetic resonance imaging (MRI) contrast agents has been analysed in terms of chemical structure, magnetic properties, {sup 1}H NMR relaxation times and biokinetics. The magnetic nanoparticles were dispersed in a strong alkaline solution in the presence of dextran, yielding stable colloids in a single step. The dispersions consist of particle-aggregates 25 nm in diameter measured using transmission electron microscope and a hydrodynamic diameter of 42 nm measured using photon correlation spectroscopy. The magnetic and relaxometric properties of the dispersions were of the same order of magnitude as those of commercial contrast agents produced using coprecipitation. However, these dispersions, when injected intravenously in rats at standard doses showed a mono-exponential blood clearance instead of a biexponential one, with a blood half-life of 7 {+-} 1 min. Furthermore, an important enhancement of the image contrast was observed after the injection, mainly located at the liver and the spleen of the rat. In conclusion, the laser pyrolysis technique seems to be a good alternative to the coprecipitation method for producing MRI contrast agents, with the advantage of being a continuous synthesis method that leads to very uniform particles capable of being dispersed and therefore transformed in a biocompatible magnetic liquid.

  10. MRI contrast agent for molecular imaging of the HER2/neu receptor using targeted magnetic nanoparticles

    Science.gov (United States)

    Rasaneh, Samira; Rajabi, Hossein; Babaei, Mohammad Hossein; Akhlaghpoor, Shahram

    2011-06-01

    In this study, Trastuzumab modified Magnetic Nanoparticles (TMNs) were prepared as a new contrast agent for detecting HER2 (Human epidermal growth factor receptor-2) expression tumors by magnetic resonance imaging (MRI). TMNs were prepared based on iron oxide nanoparticles core and Trastuzumab modified dextran coating. The TMNs core and hydrodynamic size were determined by transmission electron microscopy and dynamic light scattering. TMNs stability and cytotoxicity were investigated. The ability of TMNs for HER2 detection were evaluated in breast carcinoma cell lines (SKBr3 and MCF7 cells) and tumor-bearing mice by MRI and iron uptake determination. The particles core and hydrodynamic size were 9 ± 2.5 and 41 ± 15 nm (size range: 15-87 nm), respectively. The molar antibody/nanoparticle ratio was 3.1-3.5. TMNs were non-toxic to the cells below the 30 μg (Fe)/mL concentration and good stable up to 8 weeks in PBS buffer. TMNs could detect HER2 oncogenes in the cells surface with imagable contrast by MRI. The invivo study in mice bearing tumors indicated that TMNs possessed a good diagnostic ability as HER2 specific contrast agent by MRI. TMNs were demonstrated to be able to selectively accumulate in the tumor cells, with a proper signal enhancement in MRI T2 images. So, the complex may be considered for further investigations as an MRI contrast agent for detection of HER2 expression tumors in human.

  11. MRI contrast agent for molecular imaging of the HER2/neu receptor using targeted magnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Rasaneh, Samira; Rajabi, Hossein, E-mail: hrajabi@modares.ac.ir [Tarbiat Modares University, Department of Medical Physics (Iran, Islamic Republic of); Babaei, Mohammad Hossein [Nuclear Science and Technology Research Institute, Department of Radioisotope (Iran, Islamic Republic of); Akhlaghpoor, Shahram [Sina Hospital, Tehran Medical University, Noor Medical Imaging Center (Iran, Islamic Republic of)

    2011-06-15

    In this study, Trastuzumab modified Magnetic Nanoparticles (TMNs) were prepared as a new contrast agent for detecting HER2 (Human epidermal growth factor receptor-2) expression tumors by magnetic resonance imaging (MRI). TMNs were prepared based on iron oxide nanoparticles core and Trastuzumab modified dextran coating. The TMNs core and hydrodynamic size were determined by transmission electron microscopy and dynamic light scattering. TMNs stability and cytotoxicity were investigated. The ability of TMNs for HER2 detection were evaluated in breast carcinoma cell lines (SKBr3 and MCF7 cells) and tumor-bearing mice by MRI and iron uptake determination. The particles core and hydrodynamic size were 9 {+-} 2.5 and 41 {+-} 15 nm (size range: 15-87 nm), respectively. The molar antibody/nanoparticle ratio was 3.1-3.5. TMNs were non-toxic to the cells below the 30 {mu}g (Fe)/mL concentration and good stable up to 8 weeks in PBS buffer. TMNs could detect HER2 oncogenes in the cells surface with imagable contrast by MRI. The invivo study in mice bearing tumors indicated that TMNs possessed a good diagnostic ability as HER2 specific contrast agent by MRI. TMNs were demonstrated to be able to selectively accumulate in the tumor cells, with a proper signal enhancement in MRI T2 images. So, the complex may be considered for further investigations as an MRI contrast agent for detection of HER2 expression tumors in human.

  12. An experimental study on tissue reaction of various contrast agents on mediastinum

    International Nuclear Information System (INIS)

    Chung, Jin Wook; Kim, Hyung Jin; Kim, Seung Hyup; Park, Jae Hyung; Chang, Kee Hyun

    1989-01-01

    Till now, there is no consensus about appropriate contrast agents for use in clinical investigation in suspected perforation of the esophagus. Gastrografin, most widely used water soluble contrast agent, is less sensitive in detection of fistulous tract and can induce pulmonary edema, leading to death occasionally, if aspirated. Barium sulphate has been contraindicated without actual evaluation of its effect on mediastinum by experimental and clinical study. The purpose of this experimental study is to evaluate the type of tissue reaction and its severity in mediastinum and, as a result, to propose appropriate contrast agents in various clinical situations of suspected esophageal leakage. Barium sulphate, Hytrat, Gastrografin, Telebrix, Hexabrix, Amipaque, Niopam, and Ultravist were injected into mediastinum of 20 rats in each. The tissue reaction of injection sites were examined microscopically and graded according severity of inflammatory reaction with serial follow up from 1 day to 8 weeks after injection. The results are as follows, 1. Barium sulphate and Hytrast produced highly significant (p<0.01) tissue reaction compared to saline group and early inflammatory reaction was more severe in Hytrast. 2. Water soluble agents produced no significant reaction in mediastinum compared to saline control group and proved to be safe in the situation of leakage into mediastinum. 3. Injected barium caused no death during 8 week follow up in spite of large injected amount and histologically produced localized indolent granuloma after 4 weeks which is expected not to cause any delayed complications. In consideration of above results, superior physical characteristics of barium sulphate and drawbacks of Gastrografin, we concluded as follows. 1. For postoperative assessment of esophageal anastomosis, Barium sulphate is the contrast agent of choice

  13. Contrast media and glomerular filtration: dose dependence of clearance for three agents

    International Nuclear Information System (INIS)

    Baeck, S.E.K.; Krutzen, E.; Nilsson-Ehle, P.

    1988-01-01

    Determination of plasma clearance of contrast agents has been advocated as a means to assess glomerular filtration rate. To evaluate the feasibility of different agents for this purpose, we have compared, in healthy volunteers, the dose dependence of plasma clearance for three contrast media (iohexol, a nonionic agent, and iothalamate and metrizoate, which are ionic substances), with special emphasis on the lower dose range (2-20 mL corresponding to 0.9-12.9 g, depending on dose and agent). Iohexol and iothalamate were cleared at constant rates, irrespective of given dose, whereas metrizoate clearance increased significantly at lower doses. In general, the clearances or iothalamate and metrizoate were, respectively, moderately and markedly higher than that of iohexol. The clearance of different doses of metrizoate (2 mL versus a radiographic dose of 40 mL or more) was also compared with the clearance of [ 51 Cr]EDTA in two groups of patients with reduced renal function. When compared with [ 51 Cr]EDTA in patients with renal dysfunction, metrizoate was cleared significantly faster after a 2-mL dose, whereas clearances were identical when the metrizoate dose was 40 mL or more. These findings indicate that tubular secretion plays an active role in the elimination of metrizoate. The pharmacokinetic properties of iohexol, in combination with its low toxicity, make it a suitable agent for determination of glomerular filtration rate in clinical practice

  14. Long-term results with a nonionic contrast agent: Clinical experiences

    International Nuclear Information System (INIS)

    Hruby, W.; Urban, M.; Stellamor, K.

    1986-01-01

    From January 1982 until May 1986, 52,124 patients underwent radiologic examinations with water-soluble (ionic and nonionic) contrast media. In 1983, 2.2% of the contrast dye utilized was nonionic. In 1985 the proportion had increased to 53.3%. During the same period the rate of drug-related side effects decreased from 6.9% (1983) to 3.3% (1985). In contrast to the 1,952 drug-related side effects noted after use of ionic media, only six were noted after use of nonionic dye, for rates of 6.98% and 0.07%. The authors clinical experience with a nonionic contrast agent (iopamidol) confirms the excellent preclinical studies

  15. Iron-EHPG as an hepatobiliary MR contrast agent: initial imaging and biodistribution studies

    International Nuclear Information System (INIS)

    Lauffer, R.B.; Greif, W.L.; Stark, D.D.; Vincent, A.C.; Saini, S.; Wedeen, V.J.; Brady, T.J.

    1988-01-01

    A paramagnetic relaxation agent targeted to functioning hepatocytes of the liver and excreted into the bile would be useful in the enhancement of normal liver and biliary anatomy in MR imaging. We sought to demonstrate the feasibility of this approach using the prototype hepatobiliary MR contrast agent, iron(III) ethylenebis-(2-hydroxyphenylglycine) (Fe(EHPG) - ). The biodistribution, relaxation enhancement, and imaging characteristics of Fe(EHPG) - were compared to those of the non-specific iron chelate iron(III) diethylenetriaminepentaacetic acid (Fe(DTPA) 2- ), which has a comparable effect on water proton relaxation times. (author)

  16. Whole tissue AC susceptibility after superparamagnetic iron oxide contrast agent administration in a rat model

    Energy Technology Data Exchange (ETDEWEB)

    Lazaro, Francisco Jose [Departamento de Ciencia y Tecnologia de Materiales y Fluidos, Universidad de Zaragoza, 50018 Zaragoza (Spain) and Instituto de Nanociencia de Aragon, Universidad de Zaragoza, 50009 Zaragoza (Spain)]. E-mail: osoro@unizar.es; Gutierrez, Lucia [Departamento de Ciencia y Tecnologia de Materiales y Fluidos, Universidad de Zaragoza, 50018 Zaragoza (Spain); Rosa Abadia, Ana [Dept. Farmacologia y Fisiologia, Universidad de Zaragoza, 50013 Zaragoza (Spain); Soledad Romero, Maria [Dept. Medicina y Psiquiatria, Universidad de Zaragoza, 50009 Zaragoza (Spain); Lopez, Antonio [CNAM - Zaragoza, 50009 Zaragoza (Spain); Jesus Munoz, Maria [Dept. Farmacologia y Fisiologia, Universidad de Zaragoza, 50013 Zaragoza (Spain)

    2007-04-15

    A magnetic AC susceptibility characterisation of rat tissues after intravenous administration of superparamagnetic iron oxide (Endorem{sup (R)}), at the same dose as established for Magnetic Resonance Imaging (MRI) contrast enhancement in humans, has been carried out. The measurements reveal the presence of the contrast agent as well as that of physiological ferritin in liver and spleen while no traces have been magnetically detected in heart and kidney. This preliminary work opens suggestive possibilities for future biodistribution studies of any type of magnetic carriers.

  17. Magnetic resonance imaging with liver-specific contrast agent in primary amyloidosis and intrahepatic cholestasis

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, J.M.; Santoni-Rugiu, E.; Chabanova, E.; Logager, V.; Hansen, A.B.; Thomsen, H.S. [Depts. of Radiology and Pathology, Copenhagen Univ. Hospital, Herlev (Denmark)

    2007-02-15

    Magnetic resonance imaging (MRI) findings in hepatic amyloidosis are not well defined. Here, we report on a patient with renal failure caused by primary amyloidosis (AL type) who developed jaundice. Ultrasound and computed tomography were normal except for some ascites. MRI with oral manganese-containing contrast agent revealed several focal areas without contrast uptake in the hepatocytes and no bile secretion after 8 hours. No extrahepatic bile obstructions were found. Liver biopsy showed severe intraportal, vascular, and parenchymal amyloidosis causing severe cholestasis and atrophy of hepatocytes.

  18. Hafnium-Based Contrast Agents for X-ray Computed Tomography.

    Science.gov (United States)

    Berger, Markus; Bauser, Marcus; Frenzel, Thomas; Hilger, Christoph Stephan; Jost, Gregor; Lauria, Silvia; Morgenstern, Bernd; Neis, Christian; Pietsch, Hubertus; Sülzle, Detlev; Hegetschweiler, Kaspar

    2017-05-15

    Heavy-metal-based contrast agents (CAs) offer enhanced X-ray absorption for X-ray computed tomography (CT) compared to the currently used iodinated CAs. We report the discovery of new lanthanide and hafnium azainositol complexes and their optimization with respect to high water solubility and stability. Our efforts culminated in the synthesis of BAY-576, an uncharged hafnium complex with 3:2 stoichiometry and broken complex symmetry. The superior properties of this asymmetrically substituted hafnium CA were demonstrated by a CT angiography study in rabbits that revealed excellent signal contrast enhancement.

  19. Combined magnetic resonance imaging of deep venous thrombosis and pulmonary arteries after a single injection of a blood pool contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Hansch, Andreas; Neumann, Steffi; Baltzer, Pascal; Waginger, Matthias; Kaiser, Werner A.; Mentzel, Hans-Joachim [Friedrich-Schiller-University Jena, Institute of Diagnostic and Interventional Radiology, Jena (Germany); Betge, Stefan; Poehlmann, Gunther [Friedrich-Schiller-University Jena, Department of Internal Medicine I, Jena (Germany); Pfeil, Alexander; Wolf, Gunter [Friedrich-Schiller-University Jena, Department of Internal Medicine III, Jena (Germany); Boettcher, Joachim [SRH Klinikum Gera, Institute of Diagnostic and Interventional Radiology, Gera (Germany)

    2011-02-15

    Agreement rate between magnetic resonance imaging (MRI) and Doppler ultrasound (DUS) for the detection of deep vein thrombosis (DVT) in the lower extremities was attempted by using the intravascular MRI contrast agent gadofosveset trisodium. The potential of this method to detect pulmonary embolism (PE) was also evaluated. Forty-three consecutive inpatients with ultrasound-confirmed DVT but no clinical signs of PE were prospectively enrolled in this feasibility study. MRI was performed after a single injection of gadofosveset trisodium. The pulmonary arteries were imaged using a 3D Fast Low Angle Shot (FLASH) gradient recalled echo sequence. Additionally, pulmonary arteries, abdominal veins, pelvic and leg veins were imaged using a fat-suppressed 3D gradient echo Volume Interpolated Breath-hold Examination (VIBE FS). Gadofosveset trisodium-enhanced MRI detected more thrombi in the pelvic region, upper leg and lower leg than the initial DUS. In addition, PE was detected in 16 of the 43 DVT patients (37%). This study shows the feasibility of a combined protocol for the MRI diagnosis of DVT and PE using gadofosveset trisodium. This procedure is not only more sensitive in detecting DVT compared to standard DUS, but is also able to detect PE in asymptomatic patients. (orig.)

  20. Ferric iron with inositol hexaphosphate as a gastrointestinal MR contrast agent

    International Nuclear Information System (INIS)

    Unger, E.C.; Fritz, T.; Granstrom, P.; Palestrandt, D.; Rose, C.

    1991-01-01

    This paper reports on an inexpensive and safe gastrointestinal (GI) MR imaging contrast agent. Natural compounds known to inhibit iron absorption were prepared in phantoms with iron, and the relaxivity of these mixtures was tested via imaging at 21 MHz. Of these compounds, phytate most improved relaxivity of ferric iron. Ferric iron solutions in admixture with phytate was evaluated as a function of molar ratio of phytate to iron, pH and other additives (eg, cellulose and polyethylene glycol [PEG]). Imaging was performed on 10 volunteers who ingested a liter of the ferric/phytate agent. For comparison, 3 patients took ferric ammonium citrate without phytate. In 4 volunteers, serum iron levels were measured before and after ingestion of the ferric iron phytate contrast enhancement

  1. Small animal optoacoustic tomography system for molecular imaging of contrast agents

    Science.gov (United States)

    Su, Richard; Liopo, Anton; Ermilov, Sergey A.; Oraevsky, Alexander A.

    2016-03-01

    We developed a new and improved Laser Optoacoustic Imaging System, LOIS-3D for preclinical research applications in small animal models. The advancements include (i) a new stabilized imaging module with a more homogeneous illumination of the mouse yielding a better spatial resolution (exogenous or endogenous optoacoustic contrast agents. As examples, we present in vivo experiments using phantoms and mice with and without tumor injected with contrast agents with indocyanine green (ICG). LOIS-3D was capable of detecting ~1-2 pmole of the ICG, in tissues with relatively low blood content. With its high sensitivity and excellent spatial resolution LOIS-3D is an advanced alternative to fluorescence and bioluminescence based modalities for molecular imaging in live mice.

  2. Targeted nanodiamonds as phenotype-specific photoacoustic contrast agents for breast cancer.

    Science.gov (United States)

    Zhang, Ti; Cui, Huizhong; Fang, Chia-Yi; Cheng, Kun; Yang, Xinmai; Chang, Huan-Cheng; Forrest, M Laird

    2015-03-01

    The aim is to develop irradiated nanodiamonds (INDs) as a molecularly targeted contrast agent for high-resolution and phenotype-specific detection of breast cancer with photoacoustic (PA) imaging. The surface of acid treated radiation-damaged nanodiamonds was grafted with PEG to improve its stability and circulation time in blood, followed by conjugation to an anti-HER2 peptide with a final nanoparticle size of approximately 92 nm. Immunocompetent mice bearing orthotopic HER2-positive or negative tumors were administered INDs and PA imaged using an 820-nm near-infrared laser. PA images demonstrated that INDs accumulate in tumors and completely delineated the entire tumor within 10 h. HER2 targeting significantly enhanced imaging of HER2-positive tumors. Pathological examination demonstrated INDs are nontoxic. PA technology is adaptable to low-cost bedside medicine, and with new contrast agents described herein, PA can achieve high-resolution (sub-mm) and phenotype-specific monitoring of cancer growth.

  3. An analytical study of photoacoustic and thermoacoustic generation efficiency towards contrast agent and film design optimization

    Directory of Open Access Journals (Sweden)

    Fei Gao

    2017-09-01

    Full Text Available Photoacoustic (PA and thermoacoustic (TA effects have been explored in many applications, such as bio-imaging, laser-induced ultrasound generator, and sensitive electromagnetic (EM wave film sensor. In this paper, we propose a compact analytical PA/TA generation model to incorporate EM, thermal and mechanical parameters, etc. From the derived analytical model, both intuitive predictions and quantitative simulations are performed. It shows that beyond the EM absorption improvement, there are many other physical parameters that deserve careful consideration when designing contrast agents or film composites, followed by simulation study. Lastly, several sets of experimental results are presented to prove the feasibility of the proposed analytical model. Overall, the proposed compact model could work as a clear guidance and predication for improved PA/TA contrast agents and film generator/sensor designs in the domain area.

  4. Synthesis of functionalized magnetite nanoparticles to use as liver targeting MRI contrast agent

    Science.gov (United States)

    Yazdani, Farshad; Fattahi, Bahare; Azizi, Najmodin

    2016-05-01

    The aim of this research was the preparation of functionalized magnetite nanoparticles to use as a liver targeting contrast agent in magnetic resonance imaging (MRI). For this purpose, Fe3O4 nanoparticles were synthesized via the co-precipitation method. The synthesized nanoparticles were coated with silica via the Stober method and finally the coated nanoparticles were functionalized with mebrofenin. Formation of crystalline magnetite particles was confirmed by X-ray diffraction (XRD) analysis. The Fourier transform infrared spectroscopy (FTIR) and energy dispersive X-ray analyzer (EDX) of the final product showed that silica had been effectively bonded onto the surface of the magnetite nanoparticles and the coated nanoparticles functionalized with mebrofenin. The magnetic resonance imaging of the functional nanoparticles showed that the Fe3O4-SiO2-mebrofenin composite is an effective MRI contrast agent for liver targeting.

  5. Biocompatible Polyhydroxyethylaspartamide-based Micelles with Gadolinium for MRI Contrast Agents

    Directory of Open Access Journals (Sweden)

    Kim Hyo Jeong

    2010-01-01

    Full Text Available Abstract Biocompatible poly-[N-(2-hydroxyethyl-d,l-aspartamide]-methoxypoly(ethyleneglycol-hexadecylamine (PHEA-mPEG-C16 conjugated with 1,4,7,10-tetraazacyclododecan-1,4,7,10-tetraacetic acid-gadolinium (DOTA-Gd via ethylenediamine (ED was synthesized as a magnetic resonance imaging (MRI contrast agent. Amphiphilic PHEA-mPEG-C16-ED-DOTA-Gd forms micelle in aqueous solution. All the synthesized materials were characterized by proton nuclear magnetic resonance (1H NMR. Micelle size and shape were examined by dynamic light scattering (DLS and atomic force microscopy (AFM. Micelles with PHEA-mPEG-C16-ED-DOTA-Gd showed higher relaxivities than the commercially available gadolinium contrast agent. Moreover, the signal intensity of a rabbit liver was effectively increased after intravenous injection of PHEA-mPEG-C16-ED-DOTA-Gd.

  6. Magnetic nano-particles, contrast agent for NMR imaging; Nanoparticules magnetiques, agents de contraste pour l'imagerie par resonance magnetique

    Energy Technology Data Exchange (ETDEWEB)

    Gazeau, F.; Wilhelm, C.; Bacri, J.C. [Universite Paris 6 / associe a Paris 7, Lab. Milieux Desordonnes et Heterogenes (LMDH), 75 - Paris (France); Clement, O. [Hopital Necker-Enfants-Malades, Lab. Recherche en Imagerie, 75 - Paris (France)

    2004-08-01

    The purpose of contrast media in NMR (nuclear magnetic resonance) imaging is to disturb the magnetization of surrounding protons by generating a local magnetic field. There are 2 types of contrast agents: paramagnetic molecular complexes and ferromagnetic nano-particles. Paramagnetic molecular complexes contain paramagnetic ions such as Gd{sup 3+}, Fe{sup 3+} or Mn{sup 2+}. Ferromagnetic nano-particles are monocrystals of iron oxide whose diameters have a magnitude of about ten nanometers, each particle acts as a little magnet of 10{sup 4} Bohr magnetons. These nano-particles have to be put in colloidal suspension in a bio-compatible solvent in order to be injected into the body. The effect of nano-particles on surrounding protons is far more important than that of paramagnetic complexes because their magnetic moment is increased by a factor 1000. Paramagnetic complexes (like gadolinium chelate) do not aggregate to plasma proteins and as a consequence they go easily through capillary blood vessels, and scatter quickly in the aqueous extra-cellular compartments, they are eliminated through kidneys in a matter of hours. Magnetic nano-particles have a different kinetics inside the body that depends strongly on their sizes and the nature of their surface. Clinical uses of magnetic nano-particles involve pathology in which liver, spleen, or bone marrow are concerned, or lymphography or the visualization of the piling-up of macrophages in any inflammatory zones. (A.C.)

  7. Performance characteristics of magnetic resonance imaging without contrast agents or sedation in pediatric appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Didier, Ryne A.; Hopkins, Katharine L.; Coakley, Fergus V.; Foster, Bryan R. [Oregon Health and Science University, Department of Diagnostic Radiology, Portland, OR (United States); Krishnaswami, Sanjay [Oregon Health and Science University, Department of Surgery, Portland, OR (United States); Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States); Spiro, David M. [Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States)

    2017-09-15

    Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (P<0.01), with sensitivities of 91% and 97% and specificities of 60% and 50%. For examinations in which the appendix was not identified by one or both reviewers (23/98), the clinical outcome was negative. Rapid MRI without contrast agents or sedation is accurate for diagnosis of pediatric appendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall

  8. Chitosan-coated nickel-ferrite nanoparticles as contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ahmad, Tanveer; Bae, Hongsub; Iqbal, Yousaf; Rhee, Ilsu; Hong, Sungwook; Chang, Yongmin; Lee, Jaejun; Sohn, Derac

    2015-01-01

    We report evidence for the possible application of chitosan-coated nickel-ferrite (NiFe 2 O 4 ) nanoparticles as both T 1 and T 2 contrast agents in magnetic resonance imaging (MRI). The coating of nickel-ferrite nanoparticles with chitosan was performed simultaneously with the synthesis of the nickel-ferrite nanoparticles by a chemical co-precipitation method. The coated nanoparticles were cylindrical in shape with an average length of 17 nm and an average width of 4.4 nm. The bonding of chitosan onto the ferrite nanoparticles was confirmed by Fourier transform infrared spectroscopy. The T 1 and T 2 relaxivities were 0.858±0.04 and 1.71±0.03 mM −1 s −1 , respectively. In animal experimentation, both a 25% signal enhancement in the T 1 -weighted mage and a 71% signal loss in the T 2 -weighted image were observed. This demonstrated that chitosan-coated nickel-ferrite nanoparticles are suitable as both T 1 and T 2 contrast agents in MRI. We note that the applicability of our nanoparticles as both T 1 and T 2 contrast agents is due to their cylindrical shape, which gives rise to both inner and outer sphere processes of nanoparticles. - Highlights: • Chitosan-coated nickel-ferrite (Ni-Fe 2 O 4 ) nanoparticles were synthesized in an aqueous system by chemical co-precipitation. • The characterization of bare and chitosan-coated nanoparticles were performed using various analytical tools, such as TEM, FTIR, XRD, and VMS. • We evaluated the coated particles as potential T 1 and T 2 contrast agents for MRI by measuring T 1 and T 2 relaxation times as a function of iron concentration. • Both T 1 and T 2 effects were also observed in animal experimentation

  9. Performance characteristics of magnetic resonance imaging without contrast agents or sedation in pediatric appendicitis

    International Nuclear Information System (INIS)

    Didier, Ryne A.; Hopkins, Katharine L.; Coakley, Fergus V.; Foster, Bryan R.; Krishnaswami, Sanjay; Spiro, David M.

    2017-01-01

    Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (P<0.01), with sensitivities of 91% and 97% and specificities of 60% and 50%. For examinations in which the appendix was not identified by one or both reviewers (23/98), the clinical outcome was negative. Rapid MRI without contrast agents or sedation is accurate for diagnosis of pediatric appendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall

  10. Gadopentetate di-meglumine as contrast agent for arteriography and interventional radiologic procedures: preliminary application

    International Nuclear Information System (INIS)

    Wang Zhongpu; Wang Maoqiang; Sun Yongguang; Liu Xiaojun

    2002-01-01

    Objective: To investigate the feasibility of gadopentetate di-meglumine as contrast agent for arteriography and interventional procedures. Methods: Nine patients received gadopentetate di-meglumine as contrast agent during interventional procedures. Gadopentetate di-meglumine wa used in 2 patients with contraindications to iodinated contrast media. In addition to the standard injection sequences with iodinated contrast media, arteriograms were obtained after administration of gadopentetate di-meglumine in seven patients. Diagnostic arteriography were performed in thoracic aorta, common carotid artery, bronchial artery, intercostal artery, hepatic artery, iliac artery and uterine artery. The doses of gadopentetate di-meglumine used in this series were ≤0.3 mmol/kg. Vital signs and arterial oxygen saturation were monitored during the procedures. The blood and urine routine examinations, the hepatic and renal functions tests were done after the procedure. Results: There were no significant differences between the gadopentetate di-meglumine and the iodinated contrast media examinations for illustrating the main trunk of these arteries. Angiograms obtained with the iodinated contrast media appeared to be better than that of with gadopentetate di-meglumine for visualizing the distal branches of these arteries and the tumor stain. The interventional procedure was completed successfully in the two patients using gadopentetate di-meglumine alone. No patient suffered from complication related to the use of gadopentetate di-meglumine, and also no worsened renal function was shown after the procedure. Conclusions: Diagnostic arteriograms can be achieved safely and successfully by using gadopentetate di-meglumine, especially in patients with allergy to iodinate contrast media and chronic renal insufficiency

  11. [Intravascular endothelioma (author's transl)].

    Science.gov (United States)

    Vanĕk, J

    1978-01-01

    A 76-year-old woman developed a slowly growing lesion over the right index and the adjacent part of the metacarpus. A cell proliferation filling up the skin veins was classified as intravascular endothelioma. This rather rare oncological entity with a good prognosis should be differentiated from peculiar pattern occasionally seen in organisation of thrombi as well as malignant endothelial tumours.

  12. Harmonic Intravascular Ultrasound

    NARCIS (Netherlands)

    M.E. Frijlink (Martijn)

    2006-01-01

    textabstractMedical ultrasound is a popular imaging modality in cardiology. Harmonic Imaging is a technique that has been shown to increase the image quality of diagnostic ultrasound at frequencies below 10 MHz. However, Intravascular Ultrasound, which is a technique to acoustically investigate

  13. Computed tomography enterography: a comparison of different neutral oral contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Department of Imaging Diagnosis, Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); Braga, Fernanda Angeli; Resende, Marcelo Cardoso; Bretas, Elisa Almeida Sathler; Nunes, Thiago Franchi; Rosas, George de Queiroz; Tiferes, Dario Arie [Abdominal Imaging Section, Department of Imaging Diagnosis - Universidade Federal de Sao Paulo (Unifesp), Sao Paulo, SP (Brazil)

    2012-05-15

    Objective: The purpose of this study was to assess the performance of neutral oral contrast agents, comparing intestinal distension, distinction of intestinal wall, acceptance and side effects. Materials and Methods: Prospective, randomized, and double-blinded study involving 30 patients who underwent computed tomography of abdomen and pelvis with administration of neutral oral contrast agents, divided into three groups according the contrast agent type: milk, water, and polyethylene glycol. The images were consensually analyzed by two observers, considering the degree of bowel distension and intestinal wall distinction. The patients responded to a questionnaire regarding the taste of the ingested solution and on their side effects. Kruskal-Wallis and chi-square tests were employed for statistical analysis. Results: Among 40 studied intestinal segments, appropriate bowel distension (intestinal loop diameter > 2 cm) was observed in 14 segments (35%) in the milk group, 10 segments (25%) in the water group and 23 segments (57%) in the polyethylene glycol group (p = 0.01). Preparation with polyethylene glycol resulted in the best bowel distension, but it presented the worst taste and highest incidence of diarrhea as reported by patients. Conclusion: Bowel preparation with oral polyethylene glycol results in higher degree of bowel distension than with water or milk, but presents worst acceptance related to its taste and frequency of diarrhea as a side effect. (author)

  14. Hyperintense acute reperfusion marker is associated with higher contrast agent dosage in acute ischaemic stroke

    International Nuclear Information System (INIS)

    Ostwaldt, Ann-Christin; Schaefer, Tabea; Villringer, Kersten; Fiebach, Jochen B.; Rozanski, Michal; Ebinger, Martin; Jungehuelsing, Gerhard J.

    2015-01-01

    The hyperintense acute reperfusion marker (HARM) on fluid-attenuated inversion recovery (FLAIR) images is associated with blood-brain barrier (BBB) permeability changes. The aim of this study was to examine the influence of contrast agent dosage on HARM incidence in acute ischaemic stroke patients. We prospectively included 529 acute ischaemic stroke patients (204 females, median age 71 years). Patients underwent a first stroke-MRI within 24 hours from symptom onset and had a follow-up on day 2. The contrast agent Gadobutrol was administered to the patients for perfusion imaging or MR angiography. The total dosage was calculated as ml/kg body weight and ranged between 0.04 and 0.31 mmol/kg on the first examination. The incidence of HARM was evaluated on day 2 FLAIR images. HARM was detected in 97 patients (18.3 %). HARM incidence increased significantly with increasing dosages of Gadobutrol. Also, HARM positive patients were significantly older. HARM was not an independent predictor of worse clinical outcome, and we did not find an association with increase risk of haemorrhagic transformation. A higher dosage of Gadobutrol in acute stroke patients on initial MRI is associated with increased HARM incidence on follow-up. MRI studies on BBB should therefore standardize contrast agent dosages. (orig.)

  15. Dynamic Interactions between Contrast Agent Microbubbles: High Speed Camera Observations and Simulation Results

    Science.gov (United States)

    Stride, Eleanor; Chetty, Kevin; Eckersley, Robert

    2007-05-01

    The efficacy of coated microbubbles as contrast agents for ultrasound imaging has been well established over the past two decades. More recently, their use as carriers for targeted drug delivery has also become an active area of research. However, the behaviour of microbubbles in an ultrasound field is by no means fully understood. For example, the dynamic interactions between microbubbles have frequently been neglected when considering contrast agent suspensions. In this investigation, high speed camera observations of a commercial contrast agent (SonoVue®) were made under controlled and calibrated acoustic exposure conditions (single 4 cycle (FWHM) Gaussian pulse with 0.5 MHz centre frequency and peak negative pressure <100 kPa). These were compared with numerical simulations of both single and pairs of coated microbubbles corresponding to the experiments. Both the theoretical and experimental results indicate that the dynamic behaviour of a microbubble may be substantially affected by the presence of neighbouring bubbles under certain conditions. This, in turn, may affect the microbubble's acoustic response and its destruction threshold, which has potentially significant implications for both diagnostic and therapeutic applications.

  16. The fabrication of novel nanobubble ultrasound contrast agent for potential tumor imaging

    Energy Technology Data Exchange (ETDEWEB)

    Xing Zhanwen; Ke Hengte; Yue Xiuli; Dai Zhifei [Nanobiotechnology Division, State Key Laboratory of Urban Water Resources and Environment, School of Sciences, Harbin Institute of Technology, Harbin 150080 (China); Wang Jinrui; Zhao Bo [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China); Liu Jibin, E-mail: zhifei.dai@hit.edu.cn, E-mail: ji-bin.liu@jefferson.edu [Ultrasound Research and Education Institute, Thomas Jefferson University, Philadelphia, PA 19107 (United States)

    2010-04-09

    Novel biocompatible nanobubbles were fabricated by ultrasonication of a mixture of Span 60 and polyoxyethylene 40 stearate (PEG40S) followed by differential centrifugation to isolate the relevant subpopulation from the parent suspensions. Particle sizing analysis and optical microscopy inspection indicated that the freshly generated micro/nanobubble suspension was polydisperse and the size distribution was bimodal with large amounts of nanobubbles. To develop a nano-sized contrast agent that is small enough to leak through tumor pores, a fractionation to extract smaller bubbles by variation in the time of centrifugation at 20g (relative centrifuge field, RCF) was suggested. The results showed that the population of nanobubbles with a precisely controlled mean diameter could be sorted from the initial polydisperse suspensions to meet the specified requirements. The isolated bubbles were stable over two weeks under the protection of perfluoropropane gas. The acoustic behavior of the nano-sized contrast agent was evaluated using power Doppler imaging in a normal rabbit model. An excellent power Doppler enhancement was found in vivo renal imaging after intravenous injection of the obtained nanobubbles. Given the broad spectrum of potential clinical applications, the nano-sized contrast agent may provide a versatile adjunct for ultrasonic imaging enhancement and/or treatment of tumors.

  17. Computed tomography enterography: a comparison of different neutral oral contrast agents

    International Nuclear Information System (INIS)

    D'Ippolito, Giuseppe; Braga, Fernanda Angeli; Resende, Marcelo Cardoso; Bretas, Elisa Almeida Sathler; Nunes, Thiago Franchi; Rosas, George de Queiroz; Tiferes, Dario Arie

    2012-01-01

    Objective: The purpose of this study was to assess the performance of neutral oral contrast agents, comparing intestinal distension, distinction of intestinal wall, acceptance and side effects. Materials and Methods: Prospective, randomized, and double-blinded study involving 30 patients who underwent computed tomography of abdomen and pelvis with administration of neutral oral contrast agents, divided into three groups according the contrast agent type: milk, water, and polyethylene glycol. The images were consensually analyzed by two observers, considering the degree of bowel distension and intestinal wall distinction. The patients responded to a questionnaire regarding the taste of the ingested solution and on their side effects. Kruskal-Wallis and chi-square tests were employed for statistical analysis. Results: Among 40 studied intestinal segments, appropriate bowel distension (intestinal loop diameter > 2 cm) was observed in 14 segments (35%) in the milk group, 10 segments (25%) in the water group and 23 segments (57%) in the polyethylene glycol group (p = 0.01). Preparation with polyethylene glycol resulted in the best bowel distension, but it presented the worst taste and highest incidence of diarrhea as reported by patients. Conclusion: Bowel preparation with oral polyethylene glycol results in higher degree of bowel distension than with water or milk, but presents worst acceptance related to its taste and frequency of diarrhea as a side effect. (author)

  18. Hyperintense acute reperfusion marker is associated with higher contrast agent dosage in acute ischaemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Ostwaldt, Ann-Christin; Schaefer, Tabea; Villringer, Kersten; Fiebach, Jochen B. [Charite Universitaetsmedizin Berlin, Academic Neuroradiology, Center for Stroke Research Berlin (CSB), Berlin (Germany); Rozanski, Michal; Ebinger, Martin [Charite Universitaetsmedizin Berlin, Academic Neuroradiology, Center for Stroke Research Berlin (CSB), Berlin (Germany); Charite Universitaetsmedizin, Department of Neurology, Berlin (Germany); Jungehuelsing, Gerhard J. [Stiftung des Buergerlichen Rechts, Juedisches Krankenhaus Berlin, Berlin (Germany)

    2015-11-15

    The hyperintense acute reperfusion marker (HARM) on fluid-attenuated inversion recovery (FLAIR) images is associated with blood-brain barrier (BBB) permeability changes. The aim of this study was to examine the influence of contrast agent dosage on HARM incidence in acute ischaemic stroke patients. We prospectively included 529 acute ischaemic stroke patients (204 females, median age 71 years). Patients underwent a first stroke-MRI within 24 hours from symptom onset and had a follow-up on day 2. The contrast agent Gadobutrol was administered to the patients for perfusion imaging or MR angiography. The total dosage was calculated as ml/kg body weight and ranged between 0.04 and 0.31 mmol/kg on the first examination. The incidence of HARM was evaluated on day 2 FLAIR images. HARM was detected in 97 patients (18.3 %). HARM incidence increased significantly with increasing dosages of Gadobutrol. Also, HARM positive patients were significantly older. HARM was not an independent predictor of worse clinical outcome, and we did not find an association with increase risk of haemorrhagic transformation. A higher dosage of Gadobutrol in acute stroke patients on initial MRI is associated with increased HARM incidence on follow-up. MRI studies on BBB should therefore standardize contrast agent dosages. (orig.)

  19. ESGAR consensus statement on liver MR imaging and clinical use of liver-specific contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Neri, E.; Boraschi, P.; Bartolozzi, C. [University of Pisa, Department of Diagnostic and Interventional Radiology, Pisa (Italy); Bali, M.A.; Matos, C. [Hopital Erasme, MRI Clinics, Department of Radiology, Bruxelles (Belgium); Ba-Ssalamah, A. [The General Hospital of the Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Brancatelli, G. [University of Palermo, Department of Radiology, Palermo (Italy); Alves, F.C. [University Hospital of Coimbra, Medical Imaging Department and Faculty of Medicine, Coimbra (Portugal); Grazioli, L. [Spedali Civili di Brescia, Department of Radiology, Brescia (Italy); Helmberger, T. [Academic Teaching Hospital of the Technical University, Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Klinikum Bogenhausen, Munich (Germany); Lee, J.M. [Seoul National University College of Medicine, Division of Abdominal Imaging, Department of Radiology, Seoul (Korea, Republic of); Manfredi, R. [University of Verona, Department of Radiology, Verona (Italy); Marti-Bonmati, L. [Hospital Universitario y Politecnico La Fe, Area Clinica de Imagen Medica, Valencia (Spain); Merkle, E.M. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin, Basel (Switzerland); Op De Beeck, B. [Antwerp University Hospital, Department of Radiology, Edegem (Belgium); Schima, W. [KH Goettlicher Heiland, Krankenhaus der Barmherzigen Schwestern and Sankt Josef-Krankenhaus, Department of Diagnostic and Interventional Radiology, Vienna (Austria); Skehan, S. [St Vincent' s University Hospital, Department of Radiology, Dublin (Ireland); Vilgrain, V. [Assistance Publique-Hopitaux de Paris, APHP, Hopital Beaujon, Radiology Department, Clichy, Paris (France); Zech, C. [Universitaetsspital Basel, Abteilungsleiter Interventionelle Radiologie, Klinik fuer Radiologie und Nuklearmedizin, Basel (Switzerland)

    2016-04-15

    To develop a consensus and provide updated recommendations on liver MR imaging and the clinical use of liver-specific contrast agents. The European Society of Gastrointestinal and Abdominal Radiology (ESGAR) formed a multinational European panel of experts, selected on the basis of a literature review and their leadership in the field of liver MR imaging. A modified Delphi process was adopted to draft a list of statements. Descriptive and Cronbach's statistics were used to rate levels of agreement and internal reliability of the consensus. Three Delphi rounds were conducted and 76 statements composed on MR technique (n = 17), clinical application of liver-specific contrast agents in benign, focal liver lesions (n = 7), malignant liver lesions in non-cirrhotic (n = 9) and in cirrhotic patients (n = 18), diffuse and vascular liver diseases (n = 12), and bile ducts (n = 13). The overall mean score of agreement was 4.84 (SD ±0.17). Full consensus was reached in 22 % of all statements in all working groups, with no full consensus reached on diffuse and vascular diseases. The consensus provided updated recommendations on the methodology, and clinical indications, of MRI with liver specific contrast agents in the study of liver diseases. (orig.)

  20. Synthesis and characterization of superparamagnetic iron oxide nanoparticles as calcium-responsive MRI contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Pengfei [State Key Laboratory Breeding Base of Nonferrous Metals and Specific Materials Processing, School of Materials Science and Engineering, Guilin University of Technology, Jian Gan Road 12, Guilin 541004 (China); Shen, Zhiwei [Second Affiliated Hospital of Shantou University Medical College, Dong Xia North Road, Shantou 515041,China (China); Zhang, Baolin, E-mail: baolinzhang@ymail.com [State Key Laboratory Breeding Base of Nonferrous Metals and Specific Materials Processing, School of Materials Science and Engineering, Guilin University of Technology, Jian Gan Road 12, Guilin 541004 (China); Wang, Jun [State Key Laboratory Breeding Base of Nonferrous Metals and Specific Materials Processing, School of Materials Science and Engineering, Guilin University of Technology, Jian Gan Road 12, Guilin 541004 (China); Wu, Renhua, E-mail: rhwu@stu.edu.cn [Second Affiliated Hospital of Shantou University Medical College, Dong Xia North Road, Shantou 515041,China (China)

    2016-12-15

    Highlights: • SPIONs were conjugated with EGTA by EDC/sulfo-NHS method. • The presence of Ca{sup 2+} induced the aggregation of EGTA-SPIONs. • The aggregation of EGTA-SPIONs increased the T2 relaxation time. • EGTA-SPIONs can be used for the calcium imaging with MRI. - Abstract: Superparamagnetic iron oxide nanoparticles (SPIONs) as T2 contrast agents have great potential to sense calcium ion (Ca{sup 2+}) using magnetic resonance imaging (MRI). Here we prepared calcium-responsive SPIONs for MRI, formed by combining poly(ethylene glycol) (PEG) and polyethylenimine (PEI) coated iron oxide nanoparticle (PEI/PEG-SPIONs) contrast agents with the straightforward calcium-sensing compound EGTA (ethylene glycol tetraacetic acid). EGTA was conjugated onto PEI/PEG-SPIONs using EDC/sulfo-NHS method. EGTA-SPIONs were characterized using TEM, XPS, DSL, TGA and SQUIID. DSL results show that the SPIONs aggregate in the presence of Ca{sup 2+}. MRI analyses indicate that the water proton T2 relaxation rates in HEPES suspensions of the EGTA-SPIONs significantly increase with the calcium concentration because the SPIONs aggregate in the presence of Ca{sup 2+}. The T2 values decreased 25% when Ca{sup 2+} concentration decreased from 1.2 to 0.8 mM. The aggregation of EGTA-SPIONs could be reversed by EDTA. EGTA-SPIONs have potential as smart contrast agents for Ca{sup 2+}-sensitive MRI.

  1. Synthesis of functionalized magnetite nanoparticles to use as liver targeting MRI contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Yazdani, Farshad, E-mail: fyazdani@ccerci.ac.ir; Fattahi, Bahare; Azizi, Najmodin

    2016-05-15

    The aim of this research was the preparation of functionalized magnetite nanoparticles to use as a liver targeting contrast agent in magnetic resonance imaging (MRI). For this purpose, Fe{sub 3}O{sub 4} nanoparticles were synthesized via the co-precipitation method. The synthesized nanoparticles were coated with silica via the Stober method and finally the coated nanoparticles were functionalized with mebrofenin. Formation of crystalline magnetite particles was confirmed by X-ray diffraction (XRD) analysis. The Fourier transform infrared spectroscopy (FTIR) and energy dispersive X-ray analyzer (EDX) of the final product showed that silica had been effectively bonded onto the surface of the magnetite nanoparticles and the coated nanoparticles functionalized with mebrofenin. The magnetic resonance imaging of the functional nanoparticles showed that the Fe{sub 3}O{sub 4}–SiO{sub 2}-mebrofenin composite is an effective MRI contrast agent for liver targeting. - Highlights: • Superparamagnetic magnetite nanoparticles have been synthesized by simple and economical method. • Preperation of functional MNPs as a MRI contrast agent for liver targeting. • Gaining a good r{sub 2} relaxivity of the coated functional nanoparticles.

  2. Longitudinal study of iodine in toenails following IV administration of an iodine-containing contrast agent

    International Nuclear Information System (INIS)

    Spate, V.L.; Morris, J.S.; Nichols, T.A.; Baskett, C.K.; Mason, M.M.; Horsman, T.L.; McDougall, I.R.

    1998-01-01

    The literature on the relationship between diet and thyroid cancer (TC) risk and the higher incidence of TC among Asian immigrants to the US compared to second and third generation subgroups has prompted epidemiologists to hypothesize that increased levels of iodine consumption may be associated with TC risk, particularly among persons with a history of clinical or subclinical thyroid dysfunction. At the University of Missouri Research Reactor (MURR), we have applied epiboron neutron activation analysis to investigate human nails as a dietary monitor for iodine. Preliminary studies have indicated a positive correlation between dietary iodine intake and the concentration of iodine in toenails. However, these studies are confounded by high iodine levels (up to 30 ppm) in approximately 5% of the nails studied. We hypothesize that, in the subjects we have studied, the high iodine levels may be due to iodine-containing medications, in particular contrast-agents containing iopamidol. This paper will report on longitudinal studies using contrast agent subjects who where followed-up for almost two years compared to a longitudinal control and a population mean. Based on this study, we suggest that iodine-containing contrast agents contaminate nail samples via non-specific binding in the short term followed by incorporation in the nail as a result of absorption. (author)

  3. SU-F-T-664: The Efficacy of Gold Nanoparticles as Contrast Agents in Mice

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Y; Zhang, Y; Sajo, E [University of Massachusetts Lowell, Lowell, MA (United States); Yasmin-Karim, S; Karve, A [Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA (United States); Ngwa, W [University of Massachusetts Lowell, Lowell, MA (United States); Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: Micro-Computed Tomography (micro-CT) has been widely used as a non-invasive, high-resolution imaging modality in preclinical research. However, tumors cannot be well distinguished, since their density are similar to those of surrounding tissues, and the tumors’ natural contrast is very low. The benefits of using Gold Nanoparticles (AuNPs) as a promising high atomic weight contrast agent have been published in recent years. The aim of this study is to investigate the efficacy of AuNPs as contrast agents using different energy x-rays. Methods: The left flank of an immune-compromised athymic nude mouse was implanted with subcutaneous xenograft model of human lung cancer line, A549 cells (from ATCC). After 14 days, this mouse was imaged with dual energy cone-beam micro-CT. The selected energies were 45 kVp and 65 kVp. 10µg AuNPs (200 µg/ml concentration) approximately 12 nm in size were injected subcutaneously into the tumor. The mouse was imaged 0, 3 and 24 hours post-injection. During scanning, this mouse was anesthetized. All projection raw data have been optimized and then images were reconstructed with the FDK Algorithm. Results: Based on images, at 0 hour, AuNPs provided obvious contrast no matter which energy selected, 45 kVp or 65 kVp; and using 45 kVp X-ray, AuNps showed greater contrast. After 3 hours or evenand longer, AuNPs distributed throughout the whole body of mouse, and they were not shown clearly shown in the images. Conclusion: In this study, we investigated the efficacy of AuNPs as image contrast agents at different energies with dual-energy micro-CT, using 200µg/mL of AuNPs. Sufficiently high concentrations of AuNPs are needed to be able to track intratumoral distribution. Images showed good contrast immediately following the administration of the agent but results were poor after 3 hours.

  4. Polypyrrole coated phase-change contrast agents for sono-photoacoustic imaging (Conference Presentation)

    Science.gov (United States)

    Li, David S.; Yoon, Soon Joon; Matula, Thomas J.; O'Donnell, Matthew; Pozzo, Lilo D.

    2017-03-01

    A new light and sound sensitive nanoemulsion contrast agent is presented. The agents feature a low boiling point liquid perfluorocarbon core and a broad light spectrum absorbing polypyrrole (PPy) polymer shell. The PPy coated nanoemulsions can reversibly convert from liquid to gas phase upon cavitation of the liquid perfluorocarbon core. Cavitation can be initiated using a sufficiently high intensity acoustic pulse or from heat generation due to light absorption from a laser pulse. The emulsions can be made between 150 and 350 nm in diameter and PPy has a broad optical absorption covering both the visible spectrum and extending into the near-infrared spectrum (peak absorption 1053 nm). The size, structure, and optical absorption properties of the PPy coated nanoemulsions were characterized and compared to PPy nanoparticles (no liquid core) using dynamic light scattering, ultraviolet-visible spectrophotometry, transmission electron microscopy, and small angle X-ray scattering. The cavitation threshold and signal intensity were measured as a function of both acoustic pressure and laser fluence. Overlapping simultaneous transmission of an acoustic and laser pulse can significantly reduce the activation energy of the contrast agents to levels lower than optical or acoustic activation alone. We also demonstrate that simultaneous light and sound cavitation of the agents can be used in a new sono-photoacoustic imaging method, which enables greater sensitivity than traditional photoacoustic imaging.

  5. Intravenous, contrast-enhanced MR colonography using air as endoluminal contrast agent: Impact on colorectal polyp detection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2010-12-03

    PURPOSE: To compare diagnostic accuracy and patient tolerance of MR colonography with intravenous contrast and luminal air (MRC) to conventional colonoscopy (CC). MATERIALS AND METHODS: IRB approval and written informed consent were obtained. Forty-six patients, both screening and symptomatic, underwent MRC followed by CC. The MRC technique employed 3D T1W spoiled gradient echo sequences performed after the administration of gadopenetate dimeglumine, with parallel imaging. The diagnostic accuracy and tolerance of patients for MRC was compared to CC. RESULTS: Twenty-four polyps were detected in eighteen patients with CC (5 polyps ≥10mm, 4 polyps 6-9mm, 15 polyps ≤5mm). MRC was 66.7% (12\\/18) sensitive and 96.4% (27\\/28) specific for polyp detection on a per-patient basis. When analyzed by polyp size, sensitivity and specificity of MRC was 100% (5\\/5) and 100% (19\\/19), respectively, for lesions greater than 10mm, 100% (4\\/4) and 100% (20\\/20) for lesions 6-9mm, and sensitivity of 20% (3\\/15) lesions less than 5mm. The sensitivity and specificity of MRC for detecting significant lesions (>6mm) was 100% (9\\/9) and 100% (15\\/15), respectively. Regarding tolerance of the exams, there were no significant differences between MRC and CC. Thirty-five percent (n=16) of patients preferred MRC as a future screening test compared to 33% (n=15) for CC. CONCLUSION: MRC using air as an intraluminal contrast agent is a feasible and well-tolerated technique for detecting colonic polyps ≥6mm in size. Further studies are warranted.

  6. Intravenous, contrast-enhanced MR colonography using air as endoluminal contrast agent: Impact on colorectal polyp detection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2012-02-01

    PURPOSE: To compare diagnostic accuracy and patient tolerance of MR colonography with intravenous contrast and luminal air (MRC) to conventional colonoscopy (CC). MATERIALS AND METHODS: IRB approval and written informed consent were obtained. Forty-six patients, both screening and symptomatic, underwent MRC followed by CC. The MRC technique employed 3D T1W spoiled gradient echo sequences performed after the administration of gadopenetate dimeglumine, with parallel imaging. The diagnostic accuracy and tolerance of patients for MRC was compared to CC. RESULTS: Twenty-four polyps were detected in eighteen patients with CC (5 polyps >\\/=10mm, 4 polyps 6-9mm, 15 polyps <\\/=5mm). MRC was 66.7% (12\\/18) sensitive and 96.4% (27\\/28) specific for polyp detection on a per-patient basis. When analyzed by polyp size, sensitivity and specificity of MRC was 100% (5\\/5) and 100% (19\\/19), respectively, for lesions greater than 10mm, 100% (4\\/4) and 100% (20\\/20) for lesions 6-9mm, and sensitivity of 20% (3\\/15) lesions less than 5mm. The sensitivity and specificity of MRC for detecting significant lesions (>6mm) was 100% (9\\/9) and 100% (15\\/15), respectively. Regarding tolerance of the exams, there were no significant differences between MRC and CC. Thirty-five percent (n=16) of patients preferred MRC as a future screening test compared to 33% (n=15) for CC. CONCLUSION: MRC using air as an intraluminal contrast agent is a feasible and well-tolerated technique for detecting colonic polyps >\\/=6mm in size. Further studies are warranted.

  7. Intravenous, contrast-enhanced MR colonography using air as endoluminal contrast agent: Impact on colorectal polyp detection

    International Nuclear Information System (INIS)

    Keeling, Aoife N.; Morrin, Martina M.; McKenzie, Charles; Farrell, Richard J.; Sheth, Sunil G.; Ngo, Long; Bloch, B. Nicolas; Pedrosa, Ivan; Rofsky, Neil M.

    2012-01-01

    Purpose: To compare diagnostic accuracy and patient tolerance of MR colonography with intravenous contrast and luminal air (MRC) to conventional colonoscopy (CC). Materials and methods: IRB approval and written informed consent were obtained. Forty-six patients, both screening and symptomatic, underwent MRC followed by CC. The MRC technique employed 3D T1W spoiled gradient echo sequences performed after the administration of gadopenetate dimeglumine, with parallel imaging. The diagnostic accuracy and tolerance of patients for MRC was compared to CC. Results: Twenty-four polyps were detected in eighteen patients with CC (5 polyps ≥10 mm, 4 polyps 6–9 mm, 15 polyps ≤5 mm). MRC was 66.7% (12/18) sensitive and 96.4% (27/28) specific for polyp detection on a per-patient basis. When analyzed by polyp size, sensitivity and specificity of MRC was 100% (5/5) and 100% (19/19), respectively, for lesions greater than 10 mm, 100% (4/4) and 100% (20/20) for lesions 6–9 mm, and sensitivity of 20% (3/15) lesions less than 5 mm. The sensitivity and specificity of MRC for detecting significant lesions (>6 mm) was 100% (9/9) and 100% (15/15), respectively. Regarding tolerance of the exams, there were no significant differences between MRC and CC. Thirty-five percent (n = 16) of patients preferred MRC as a future screening test compared to 33% (n = 15) for CC. Conclusion: MRC using air as an intraluminal contrast agent is a feasible and well-tolerated technique for detecting colonic polyps ≥6 mm in size. Further studies are warranted.

  8. Evaluation of date syrup as an oral negative contrast agent for MRCP.

    Science.gov (United States)

    Govindarajan, Arunkumar; Lakshmanan, Prakash Manikka; Sarawagi, Radha; Prabhakaran, Velu

    2014-11-01

    The purpose of this study was to compare the in vitro effects of date syrup with those of other contrast agents by qualitative and quantitative analysis and in vivo evaluation of the use of date syrup to improve the quality of MRCP images. Phantoms containing date syrup, ferumoxsil, pineapple juice, and water were imaged by 1.5-T MRI with T2-weighted and MRCP sequences, and signal-to-noise ratios were calculated. Biochemical analysis of date syrup was performed to find the nature of iron in it, and the iron content was quantified by energy-dispersive x-ray spectroscopy. Sixty patients underwent MRCP before and 30 minutes after ingestion of 100 mL of date syrup. Unenhanced and contrast-enhanced images were scored for gastrointestinal tract signal suppression and visualization of various pancreaticobiliary structures. In vitro evaluation showed that images obtained with date syrup had a signal-to-noise ratio comparable to that of images obtained with ferumoxsil in T2-weighted and MRCP sequences. The iron concentration in date syrup was 2.6 mg/dL, and it was in ferric form. Images obtained after oral contrast administration had statistically significant improvement in gastrointestinal tract signal suppression (p syrup can be used as a negative oral contrast agent for gastrointestinal tract signal suppression during MRCP and for improving visualization of various pancreaticobiliary structures.

  9. Barium sulfate suspension as a negative oral contrast agent for MR imaging

    International Nuclear Information System (INIS)

    Li, K.C.P.; Tart, R.P.; Fitzsimmons, J.R.; Storm, B.; Mao, J.

    1989-01-01

    Proton spectroscopy with linewidth measurements and MR imaging were performed on various commercially available barium sulfate suspensions as well as inorganic sulfates and barium salts. Approximately 500 mL of 20%, 40%, 60%, and 70% wt/wt single-contrast oral barium sulfate suspensions were administered to four normal volunteers, and MR imaging was performed with both a 1.5-T and a 0.15-T MR imager. As much as 80% of the small bowel and the entire colon were well visualized with the 60% or 70% wt/wt single-contrast barium sulfate suspensions. The authors conclude that barium sulfate suspensions are useful as oral MR contrast agents

  10. Design of a modular protein-based MRI contrast agent for targeted application.

    Directory of Open Access Journals (Sweden)

    Daniel Grum

    Full Text Available Magnetic resonance imaging (MRI offers a non-radioactive alternative for the non-invasive detection of tumours. Low molecular weight MRI contrast agents currently in clinical use suffer either from a lack of specificity for tumour tissue or from low relaxivity and thus low contrast amplification. In this study, we present the newly designed two domain fusion protein Zarvin, which is able to bind to therapeutic IgG antibodies suitable for targeting, while facilitating contrast enhancement through high affinity binding sites for Gd(3+. We show that the Zarvin fold is stable under serum conditions, specifically targets a cancer cell-line when bound to the Cetuximab IgG, and allows for imaging with high relaxivity, a property that would be advantageous for the detection of small tumours and metastases at 1.5 or 3 T.

  11. Effects of microchannel confinement on acoustic vaporisation of ultrasound phase change contrast agents

    Science.gov (United States)

    Lin, Shengtao; Zhang, Ge; Hau Leow, Chee; Tang, Meng-Xing

    2017-09-01

    The sub-micron phase change contrast agent (PCCA) composed of a perfluorocarbon liquid core can be activated into gaseous state and form stable echogenic microbubbles for contrast-enhanced ultrasound imaging. It has shown great promise in imaging microvasculature, tumour microenvironment, and cancer cells. Although PCCAs have been extensively studied for different diagnostic and therapeutic applications, the effect of biologically geometrical confinement on the acoustic vaporisation of PCCAs is still not clear. We have investigated the difference in PCCA-produced ultrasound contrast enhancement after acoustic activation with and without a microvessel confinement on a microchannel phantom. The experimental results indicated more than one-order of magnitude less acoustic vaporisation in a microchannel than that in a free environment taking into account the attenuation effect of the vessel on the microbubble scattering. This may provide an improved understanding in the applications of PCCAs in vivo.

  12. Harmonic US imaging of vesicoureteric reflux in children: usefulness of a second generation US contrast agent.

    Science.gov (United States)

    Ascenti, Giorgio; Zimbaro, Giovanni; Mazziotti, Silvio; Chimenz, Roberto; Fede, Carmelo; Visalli, Carmela; Scribano, Emanuele

    2004-06-01

    Contrast-enhanced voiding urosonography (VUS) is largely accepted both for the diagnosis and follow-up of vesicoureteric reflux (VUR) in children. To evaluate the usefulness of contrast-enhanced second-harmonic VUS in the diagnosis and grading of VUR, using a second-generation contrast agent. Eighty consecutive children were prospectively studied with contrast-enhanced second-harmonic VUS. All children received a second-generation contrast medium, constituted by phospholipid-stabilized microbubbles of sulphur-hexafluoride (SonoVue, Bracco, Milan, Italy). US monitoring of the bladder, of the retrovesical space and of the kidneys was performed using, alternatively, both tissue-harmonic and contrast-harmonic modes. In those young boys where VUR was depicted at VUS, examination was completed with transperineal, sagittal urethral exploration during micturition. VUR was graded in five steps and diagnoses were compared with voiding cystourethrography (VCUG). VUR was diagnosed in 52 reno-ureteral units with VUS. In 49 of these reno-ureteral units, VCUG confirmed the presence of VUR. In comparison to VUS, sensitivity and negative predictive value of VCUG were inferior. The grade of VUR detected at VUS was higher than that detected at VCUG in three units. In no case was the grade of VUR detected at VCUG higher than the one detected at VUS. The differences between VUS and VCUG in grading VUR were statistically significant (p=0.02). Imaging of the normal posterior urethra was skilfully demonstrated with US in 15 young boys with VUR. No statistically significant differences were found between tissue-harmonic and contrast-harmonic mode (p=0.102). Contrast-enhanced second-harmonic VUS is a sensitive and easy technique for the evaluation of VUR. A second-generation US contrast medium such as SonoVue, if available, should be the first choice as the dose required for one examination is much lower and consequently significant reduction of contrast agent cost is possible. Copyright

  13. Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study.

    Science.gov (United States)

    Kingston, Mitchell J; Perriman, Diana M; Neeman, Teresa; Smith, Paul N; Webb, Alexandra L

    2016-07-01

    Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four sets of cannulae of known diameter, were injected with one of three different contrast agents (barium sulfate and resin, barium sulfate and gelatin, and lead oxide combined with milk powder). All were then scanned using micro-computed tomography (CT) angiography and 3-D reconstructions generated. The number of branching generations of the rat lower limb vessels were counted and compared between the contrast agents using ANOVA. The diameter of the contrast-filled cannulae, were measured and used to calculate the accuracy of the measurements by comparing the bias and variance of the estimates. Intra- and inter-observer reliability were calculated using intra-class correlation coefficients. There was no significant difference (mean difference [MD] 0.05; MD 95% confidence interval [CI] -0.83 to 0.93) between the number of branching generations for barium sulfate-resin and lead oxide-milk powder. Barium sulfate-resin demonstrated less bias and less variance of the estimates (MD 0.03; standard deviation [SD] 1.96 mm) compared to lead oxide-milk powder (MD 0.11; SD 1.96 mm) for measurements of contrast-filled cannulae scanned at high resolution. Barium sulfate-resin proved to be more accurate than lead oxide-milk powder for high resolution micro-CT scans and is preferred due to its non-toxicity. This technique could be applied to any embalmed specimen model. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Evaluation of chirp reversal power modulation sequence for contrast agent imaging

    Science.gov (United States)

    Novell, A.; Sennoga, CA; Escoffre, JM; Chaline, J.; Bouakaz, A.

    2014-09-01

    Over the last decade, significant research effort has been focused on the use of chirp for contrast agent imaging because chirps are known to significantly increase imaging contrast-to-noise ratio (CNR). New imaging schemes, such as chirp reversal (CR), have been developed to improve contrast detection by increasing non-linear microbubble responses. In this study we evaluated the contrast enhancement efficiency of various chirped imaging sequences in combination with well-established imaging schemes such as power modulation (PM) and pulse inversion (PI). The imaging schemes tested were implemented on a fully programmable open scanner and evaluated by ultrasonically scanning (excitation frequency of 2.5 MHz amplitude of 350 kPa) a tissue-mimicking flow phantom comprising a 4 mm diameter tube through which aqueous dispersions (dilution fraction of 1/2000) of the commercial ultrasound contrast agent, SonoVue® were continuously circulated. The recovery of non-linear microbubble responses after chirp compression requires the development and the optimization of a specific filter. A compression filter was therefore designed and used to compress and extract several non-linear components from the received microbubble responses. The results showed that using chirps increased the image CNR by approximately 10 dB, as compared to conventional Gaussian apodized sine burst excitation but degraded the axial resolution by a factor of 1.4, at -3 dB. We demonstrated that the highest CNR and contrast-to-noise ratio (CTR) were achievable when CR was combined with PM as compared to other imaging schemes such as PI.

  15. Risk Stratification of iodine-induced thyrotoxicosis before contrast agent application

    International Nuclear Information System (INIS)

    Fricke, E.

    2004-01-01

    Today, examinations using iodine containing contrast media are rather frequent. Even though in modern contrast agents the content of free iodine is low, in vivo deiodination results in a non physiologic high iodine load of the thyroid gland. Whilst in normal thyroid tissue iodine metabolism and hormone production are self-regulating in spite of the variable iodine load, those mechanisms are disturbed in autonomous thyroid tissue. Clinical studies displayed low risk of iodine induced thyrotoxicosis after application of contrast agent. Nonetheless the clinician has to assess the risk of thyrotoxicosis for each individual patient and he has to decide how to cope with this risk. Thyroid scintigraphy using Tc-99m-pertechnetate with quantitative measurement of the thyroidal uptake (TcTU) has been shown to be a useful tool in this question, especially when performed under suppression of the non-autonomous tissue (TcTUs). In particular patients with pre-existing suppression of the TSH secretion should be selected for this investigation. Also at risk are elderly persons and those with diffuse or nodular goitres. In spite of the high frequency of contrast agent applications, data on scintigraphy for risk evaluation of thyrotoxicosis and on efficacy of prophylactic medication are scarce. Based on own results and on a review of literature, the risk of thyrotoxicosis seems to be negligible in patients with a TcTUs of less than 1% even in case of preexistent latent hyperthyroidism. If a suppressed TSH level is known and TcTUs is higher than 1%, prophylactic medication should be given. There is evidence for a combination therapy inhibiting both iodine uptake and metabolism, i.e. with perchlorate and thiamazole, being more efficient than monotherapy, particularly in patients with high risk of thyrotoxicosis. (orig.)

  16. Enhanced conjugation stability and blood circulation time of macromolecular gadolinium-DTPA contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Jenjob, Ratchapol [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of); Kun, Na [Department of Biotechnology, The Catholic University of Korea, 43 Jibong-ro, Wonmi-gu, Bucheon-si, Gyeonggi-do 420-743 (Korea, Republic of); Ghee, Jung Yeon [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Shen, Zheyu; Wu, Xiaoxia [Division of Functional Materials and Nano-Devices, Ningbo Institute of Materials Technology & Engineering (NIMTE), Chinese Academy of Sciences, 519 Zhuangshi Street, Zhenhai District, Ningbo, Zhejiang 315201 (China); Cho, Steve K., E-mail: scho@gist.ac.kr [Division of Liberal Arts and Science, GIST College, Gwangju Institute of Science and Technology, Gwangju 500-712 (Korea, Republic of); Lee, Don Haeng [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Department of Internal Medicine, School of Medicine, Inha University Hospital, Incheon 420-751 (Korea, Republic of); Yang, Su-Geun, E-mail: Sugeun.Yang@Inha.ac.kr [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of)

    2016-04-01

    In this study, we prepared macromolecular MR T1 contrast agent: pullulan-conjugated Gd diethylene triamine pentaacetate (Gd-DTPA-Pullulan) and estimated residual free Gd{sup 3+}, chelation stability in competition with metal ions, plasma and tissue pharmacokinetics, and abdominal MR contrast on rats. Residual free Gd{sup 3+} in Gd-DTPA-Pullulan was measured using colorimetric spectroscopy. The transmetalation of Gd{sup 3+} incubated with Ca{sup 2+} was performed by using a dialysis membrane (MWCO 100–500 Da) and investigated by ICP-OES. The plasma concentration profiles of Gd-DTPA-Pullulan were estimated after intravenous injection at a dose 0.1 mmol/kg of Gd. The coronal-plane abdominal images of normal rats were observed by MR imaging. The content of free Gd{sup 3+}, the toxic residual form, was less than 0.01%. Chelation stability of Gd-DTPA-Pullulan was estimated, and only 0.2% and 0.00045% of Gd{sup 3+} were released from Gd-DTPA-Pullulan after 2 h incubation with Ca{sup 2+} and Fe{sup 2+}, respectively. Gd-DTPA-Pullulan displayed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h), much longer than 0.11 h and 0.79 h of Gd-EOB-DTPA. Abdominal MR imaging showed Gd-DTPA-Pullulan maintained initial MR contrast for 30 min. The extended plasma half-life of Gd-DTPA-Pullulan probably allows the prolonged MR acquisition time in clinic with enhanced MR contrast. - Highlights: • Macromolecule (pullulan) conjugated Gd contrast agent (Gd-DTPA-Pullulan) showed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h) in comparison with Gd-EOB-DTPA • Gd-DTPA-pullulan T1 contrast agent exhibited strong chelation stability against Gd. • The extended blood circulation attributed the enhanced and prolonged MR contrast on abdominal region of rats. • The extended blood circulation may provide prolonged MR acquisition time window in clinics.

  17. Delivery of Optical Contrast Agents using Triton-X100, Part 1: Reversible permeabilization of live cells for intracellular labeling

    OpenAIRE

    van de Ven, Anne L; Adler-Storthz, Karen; Richards-Kortum, Rebecca

    2009-01-01

    Effective delivery of optical contrast agents into live cells remains a significant challenge. We sought to determine whether Triton-X100, a detergent commonly used for membrane isolation and protein purification, could be used to effectively and reversibly permeabilize live cells for delivery of targeted optical contrast agents. Although Triton-X100 is widely recognized as a good cell permeabilization agent, no systematic study has evaluated the efficiency, reproducibility, and reversibility...

  18. Tracking T-cells in vivo with a new nano-sized MRI contrast agent.

    Science.gov (United States)

    Liu, Li; Ye, Qing; Wu, Yijen; Hsieh, Wen-Yuan; Chen, Chih-Lung; Shen, Hsin-Hsin; Wang, Shian-Jy; Zhang, Haosen; Hitchens, T Kevin; Ho, Chien

    2012-11-01

    Non-invasive in vivo tracking of T-cells by magnetic resonance imaging (MRI) can lead to a better understanding of many pathophysiological situations, including AIDS, cancer, diabetes, graft rejection. However, an efficient MRI contrast agent and a reliable technique to track non-phagocytic T-cells are needed. We report a novel superparamagnetic nano-sized iron-oxide particle, IOPC-NH2 series particles, coated with polyethylene glycol (PEG), with high transverse relaxivity (250 s(-1) mM(-1)), thus useful for MRI studies. IOPC-NH2 particles are the first reported magnetic particles that can label rat and human T-cells with over 90% efficiency, without using transfection agents, HIV-1 transactivator peptide, or electroporation. IOPC-NH2 particles do not cause any measurable effects on T-cell properties. Infiltration of IOPC-NH2-labeled T-cells can be detected in a rat model of heart-lung transplantation by in vivo MRI. IOPC-NH2 is potentially valuable contrast agents for labeling a variety of cells for basic and clinical cellular MRI studies, e.g., cellular therapy. In this study, a novel PEG coated superparamagnetic nano-sized iron-oxide particle was investigated as a T-cell labeling agent for MRI studies. The reported particles can label T-cells with over 90% efficiency, without using transfection agents, HIV-1 transactivator peptide, or electroporation, therefore may enable more convenient preclinical call labeling studies. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Liposomes loaded with hydrophilic magnetite nanoparticles: Preparation and application as contrast agents for magnetic resonance imaging.

    Science.gov (United States)

    German, S V; Navolokin, N A; Kuznetsova, N R; Zuev, V V; Inozemtseva, O A; Anis'kov, A A; Volkova, E K; Bucharskaya, A B; Maslyakova, G N; Fakhrullin, R F; Terentyuk, G S; Vodovozova, E L; Gorin, D A

    2015-11-01

    Magnetic fluid-loaded liposomes (MFLs) were fabricated using magnetite nanoparticles (MNPs) and natural phospholipids via the thin film hydration method followed by extrusion. The size distribution and composition of MFLs were studied using dynamic light scattering and spectrophotometry. The effective ranges of magnetite concentration in MNPs hydrosol and MFLs for contrasting at both T2 and T1 relaxation were determined. On T2 weighted images, the MFLs effectively increased the contrast if compared with MNPs hydrosol, while on T1 weighted images, MNPs hydrosol contrasting was more efficient than that of MFLs. In vivo magnetic resonance imaging (MRI) contrasting properties of MFLs and their effects on tumor and normal tissues morphology, were investigated in rats with transplanted renal cell carcinoma upon intratumoral administration of MFLs. No significant morphological changes in rat internal organs upon intratumoral injection of MFLs were detected, suggesting that the liposomes are relatively safe and can be used as the potential contrasting agents for MRI. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Facile Synthesis of Gd-Functionalized Gold Nanoclusters as Potential MRI/CT Contrast Agents

    Directory of Open Access Journals (Sweden)

    Wenjun Le

    2016-04-01

    Full Text Available Multi-modal imaging plays a key role in the earlier detection of disease. In this work, a facile bioinspired method was developed to synthesize Gd-functionalized gold nanoclusters (Gd-Au NCs. The Gd-Au NCs exhibit a uniform size, with an average size of 5.6 nm in dynamic light scattering (DLS, which is a bit bigger than gold clusters (3.74 nm, DLS, while the fluorescent properties of Gd-Au NCs are almost the same as that of Au NCs. Moreover, the Gd-Au NCs exhibit a high longitudinal relaxivity value (r1 of 22.111 s−1 per mM of Gd in phosphate-buffered saline (PBS, which is six times higher than that of commercial Magnevist (A complex of gadolinium with a chelating agent, diethylenetriamine penta-acetic acid, Gd-DTPA, r1 = 3.56 mM−1·s−1. Besides, as evaluated by nano single photon emission computed tomography (SPECT and computed tomography (CT the Gd-Au NCs have a potential application as CT contrast agents because of the Au element. Finally, the Gd-Au NCs show little cytotoxicity, even when the Au concentration is up to 250 μM. Thus, the Gd-Au NCs can act as multi-modal imaging contrast agents.

  1. Ferric ammonium citrate as a positive bowel contrast agent for MR imaging of the upper abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Kivelitz, D.; Taupitz, M.; Hamm, B. [Universitaetsklinikum Charite, Berlin (Germany). Inst. fuer Radiologie; Gehl, H.B. [Medizinische Univ. Luebeck (Germany). Inst. fuer Radiologie; Heuck, A. [Muenchen Univ. (Germany). Radiologische Klinik; Krahe, T. [Koeln Univ. (Germany). Inst. fuer Radiologische Diagnostik; Lodemann, K.P. [Bracco-Byk Gulden GmbH, Konstanz (Germany)

    1999-07-01

    Purpose: To evaluate the safety and diagnostic efficacy of two different doses of ferric ammonium citrate as a paramagnetic oral contrast agent for MR imaging of the upper abdomen. Material and methods: Ninety-nine adult patients referred for MR imaging for a known or suspected upper abdominal pathology were included in this randomized multicenter double-blind clinical trial. Imaging was performed with spin-echo (T1- and T2-weighted) and gradient-echo (T1-weighted) techniques before and after administration of either 1200 mg or 2400 mg of ferric ammonium citrate dissolved in 600 ml of water. Safety analysis included monitoring of vital signs, assessment of adverse events, and laboratory testing. Efficacy with regard to organ distension, contrast distribution, bowel enhancement and delineation of adjacent structures was graded qualitatively. Results: No serious adverse events were reported for either of the two concentrations. A total of 31 minor side effects were noted, of which significantly more occurred in the higher dose group (p<0.01). The diagnostic confidence in defining or excluding disease was graded as better after contrast administration for 48% of all images. Marked or moderate enhancement of the upper gastrointestinal tract was achieved at both doses in 69.5% of cases with no evident difference between the two doses. The higher dose tended to show better results in terms of the contrast assessment parameters. Conclusion: Ferric ammonium citrate is a safe and effective oral contrast agent for MR imaging of the upper abdomen at two different dose levels. The higher dose showed a tendency toward better imaging results while the lower dose caused significantly fewer side effects. Therefore, the 1200 mg dose can be recommended in view of the risk-to-benefit ratio. (orig.)

  2. Inorganic nanocrystals as contrast agents in MRI:synthesis, coating and introducing multifunctionality

    Science.gov (United States)

    Sanchez-Gaytan, Brenda L.; Mieszawska, Aneta J.; Fayad, Zahi A.

    2013-01-01

    Inorganic nanocrystals have myriad applications in medicine, which includes their use as drug or gene delivery complexes, therapeutic hyperthermia agents, in diagnostic systems and as contrast agents in a wide range of medical imaging techniques. For MRI, nanocrystals can produce contrast themselves, of which iron oxides have been most extensively explored, or be given a coating that generates MR contrast, for example gold nanoparticles coated with gadolinium chelates. These MR-active nanocrystals can be used in imaging of the vasculature, liver and other organs, as well as molecular imaging, cell tracking and theranostics. Due to these exciting applications, synthesizing and rendering these nanocrystals water-soluble and biocompatible is therefore highly desirable. We will discuss aqueous phase and organic phase methods for synthesizing inorganic nanocrystals such as gold, iron oxides and quantum dots. The pros and cons of the various methods will be highlighted. We explore various methods for making nanocrystals biocompatible, i.e. directly synthesizing nanocrystals coated with biocompatible coatings, ligand substitution, amphiphile coating and embedding in carrier matrices that can be made biocompatible. Various examples will be highlighted and their applications explained. These examples signify that synthesizing biocompatible nanocrystals with controlled properties has been achieved by numerous research groups and can be applied for a wide range of applications. Therefore we expect to see reports of preclinical applications of ever more complex MRI-active nanoparticles and their wider exploitation, as well as in novel clinical settings. PMID:23303729

  3. Silicon nanoparticles as contrast agents in the methods of optical biomedical diagnostics

    Science.gov (United States)

    Zabotnov, S. V.; Kashaev, F. V.; Shuleiko, D. V.; Gongalsky, M. B.; Golovan, L. A.; Kashkarov, P. K.; Loginova, D. A.; Agrba, P. D.; Sergeeva, E. A.; Kirillin, M. Yu

    2017-07-01

    The efficiency of light scattering by nanoparticles formed using the method of picosecond laser ablation of silicon in water and by nanoparticles of mechanically grinded mesoporous silicon is compared. The ensembles of particles of both types possess the scattering coefficients sufficient to use them as contrast agents in optical coherence tomography (OCT), particularly in the range of wavelengths 700-1000 nm, where the absorption of both silicon and most biological and mimicking tissues is small. According to the Mie theory the main contribution to the scattering in this case is made by the particles having a relatively large size (150-300 nm). In the experiments on visualising the agar phantom surface by means of OCT, the contrast of the medium boundary, provided by nanoparticles amounted to 14 dB and 30 dB for the ablated particles and the porous silicon powder, respectively. The numerical simulation of OCT images of skin in the presence of nanoparticles, confirmed the efficiency of using them as a contrast agent.

  4. Saline as the sole contrast agent for successful MRI-guided epidural injections.

    Science.gov (United States)

    Deli, Martin; Fritz, Jan; Mateiescu, Serban; Busch, Martin; Carrino, John A; Becker, Jan; Garmer, Marietta; Grönemeyer, Dietrich

    2013-06-01

    To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. 105 MRI-guided epidural injections (12 of 105 with gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 ± 9 min in the gadolinium-enhanced saline solution group and 22 ± 8 min in the saline solution group (p = 0.75). Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.

  5. Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections

    Energy Technology Data Exchange (ETDEWEB)

    Deli, Martin, E-mail: martin.deli@web.de [University of Witten/Herdecke, Department of Radiology and Microtherapy, Groenemeyer Institute for Microtherapy (GIMT) (Germany); Fritz, Jan, E-mail: jfritz9@jhmi.edu [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science (United States); Mateiescu, Serban, E-mail: mateiescu@microtherapy.de; Busch, Martin, E-mail: busch@microtherapy.de [University of Witten/Herdecke, Department of Radiology and Microtherapy, Groenemeyer Institute for Microtherapy (GIMT) (Germany); Carrino, John A., E-mail: jcarrin2@jhmi.edu [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science (United States); Becker, Jan, E-mail: j.becker@microtherapy.de; Garmer, Marietta, E-mail: garmer@microtherapy.de; Groenemeyer, Dietrich, E-mail: dg@microtherapy.de [University of Witten/Herdecke, Department of Radiology and Microtherapy, Groenemeyer Institute for Microtherapy (GIMT) (Germany)

    2013-06-15

    Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 with gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 {+-} 9 min in the gadolinium-enhanced saline solution group and 22 {+-} 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.

  6. Development of New Contrast Agents for Imaging Function and Metabolism by Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Alexandra Carvalho

    2017-07-01

    Full Text Available Liposomes are interesting nanosystems with a wide range of medical application. One particular application is their ability to enhance contrast in magnetic resonance images; when properly loaded with magnetic/superparamagnetic nanoparticles, this means to act as contrast agents. The design of liposomes loaded with magnetic particles, magnetoliposomes, presents a large number of possibilities depending on the application from image function to metabolism. More interesting is its double function application as theranostics (diagnostics and therapy. The synthesis, characterization, and possible medical applications of two types of magnetoliposomes are reviewed. Their performance will be compared, in particular, their efficiency as contrast agents for magnetic resonance imaging, measured by their relaxivities r 1 and r 2 relating to their particular composition. One of the magnetoliposomes had 1,2-diacyl-sn-glycero-3-phosphocholine (soy as the main phospholipid component, with and without cholesterol, varying its phospholipid to cholesterol molar ratios. The other formulation is a long-circulating liposome composed of 1,2-diacyl-sn-glycero-3-phosphocholine (egg, cholesterol, and 1,2-distearoyl-sn-glycerol-3-phosphoethanolamine- N -[methoxy(polyethylene glycol-2000]. Both nanosystems were loaded with superparamagnetic iron oxide nanoparticles with different sizes and coatings.

  7. Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections

    International Nuclear Information System (INIS)

    Deli, Martin; Fritz, Jan; Mateiescu, Serban; Busch, Martin; Carrino, John A.; Becker, Jan; Garmer, Marietta; Grönemeyer, Dietrich

    2013-01-01

    Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 with gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 ± 9 min in the gadolinium-enhanced saline solution group and 22 ± 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.

  8. Hydrazo-CEST: Hydrazone-dependent Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast Agents.

    Science.gov (United States)

    Dang, Trina; Suchy, Mojmir; Truong, Yen; Oakden, Wendy; Lam, Wilfred; Lazurko, Caitlin; Facey, Glenn; Stanisz, Greg; Shuhendler, Adam

    2018-04-12

    The rapid formation of hydrazones under physiological conditions was exploited for the detection of aldehydes through chemical exchange saturation transfer magnetic resonance imaging (CEST-MRI). A metal-free, diamagnetic contrast agent derived from N-amino anthranilic acid was introduced, which selectively 'turned-on' upon hydrazone formation through an effect termed Hydrazo-CEST. While the hydrazine form of the probe produced no CEST-MRI signal enhancement, the formation of the aryl hydrazone resulted in >20% intensity decrease in the bulk water signal through the CEST effect, as measured by 300 MHz 1H NMR, 3T and 7T MRI. Both the electronic contributions of the N-amino anthranilate and the aldehyde binding partner were shown to directly impact the exchange rate of the proton on the ring-proximal nitrogen, and thus the imaging signal. Additionally, the presence of the carboxylic acid moiety ortho to the hydrazine was necessary not only for contrast production, but also for rapid hydrazone formation and prolonged hydrazone product stability under physiological conditions. This work provided the first example of an MRI-based contrast agent capable of a 'turn on' response upon reaction with bioactive aldehydes, and outlined both the structural and electronic requirements to expand on Hydrazo-CEST, a novel, hydrazone-dependent subtype of diamagnetic CEST-MRI. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Large abnormal peak on capillary zone electrophoresis due to contrast agent.

    Science.gov (United States)

    Wheeler, Rachel D; Zhang, Liqun; Sheldon, Joanna

    2017-01-01

    Background Some iodinated radio-contrast media absorb ultraviolet light and can therefore be detected by capillary zone electrophoresis. If seen, these peaks are typically small with 'quantifications' of below 5 g/L. Here, we describe the detection of a large peak on capillary zone electrophoresis that was due to the radio-contrast agent, Omnipaque™. Methods Serum from a patient was analysed by capillary zone electrophoresis, and the IgG, IgA, IgM and total protein concentrations were measured. The serum sample was further analysed by gel electrophoresis and immunofixation. Results Capillary zone electrophoresis results for the serum sample showed a large peak with a concentration high enough to warrant urgent investigation. However, careful interpretation alongside the serum immunoglobulin concentrations and total protein concentration showed that the abnormal peak was a pseudoparaprotein rather than a monoclonal immunoglobulin. This was confirmed by analysis with gel electrophoresis and also serum immunofixation. The patient had had a CT angiogram with the radio-contrast agent Omnipaque™; addition of Omnipaque™ to a normal serum sample gave a peak with comparable mobility to the pseudoparaprotein in the patient's serum. Conclusions Pseudoparaproteins can appear as a large band on capillary zone electrophoresis. This case highlights the importance of a laboratory process that detects significant electrophoretic abnormalities promptly and interprets them in the context of the immunoglobulin concentrations. This should avoid incorrect reporting of pseudoparaproteins which could result in the patient having unnecessary investigations.

  10. Copper sulfide nanodisk as photoacoustic contrast agent for ovarian tumor detection

    Science.gov (United States)

    Wang, Junxin; Hsu, Su-Wen; Tao, Andrea R.; Jokerst, Jesse V.

    2017-03-01

    Ultrasound is broadly used in the clinics yet is limited in early cancer detection because of its poor contrast between healthy and diseased tissues. Photoacoustic imaging can improve this limitation and has been extensively studied in pre-clinical models. Contrast agents can help improve the accuracy of diagnosis. We recently reported a novel copper sulfide (CuS) nanodisk with strong directionally-localized surface plasmon resonance in the near infrared region. This plasmonic resonance of nanodisks is tunable by changing the size and aspect ratio of CuS nanodisk. Here, we demonstrate this CuS nanodisk is a strong photoacoustic contrast agent. We prepared CuS nanodisks via a solvent-based synthesis followed by surface modification of poly(ethylene glycol) methyl ether thiol for in vivo applications. These CuS nanodisks can be detected at a concentration as low as 26 pM at 920 nm. Their nanosize and strong photoacoustic response make this novel CuS nanodisk a strong candidate for photoacoustic cancer imaging.

  11. Intravascular (catheter) MR imaging

    International Nuclear Information System (INIS)

    Cohen, A.M.; Hurst, G.C.; Katz, D.E.; Dverk, J.L.; Wiesen, E.J.; Czerski, L.W.; Malaya, R.; Bellon, E.M.

    1989-01-01

    Intravascular MR probes allow excellent spatial resolution and have the potential to detect arterial wall microstructure. Ultrasonic intravascular probes suggest that detailed morphologic information can assist clinical decision making. Catheter MR probes of 2--7 mm outside diameter (OD) were built of copper wire, Teflon, and parts from standard commercial catheters. The probes were connected to the surface coil receiver input of our Picker VISTA 2055HP 1.5-T imaging system. The extant (linear) body coil was used for transmit. Phantoms were constructed of coaxial glass MR tubes, filled with doped water. Watanabe rabbit aorta and human autopsy iliac artery specimens were examined within 4 hours of excision or stored by freezing. In vivo iliac arteries in dogs under general anesthesia were imaged, with percutaneous placement of the probe. Results are presented

  12. CONTRAST

    DEFF Research Database (Denmark)

    Kristensen, Thomas Krogsgaard

    2007-01-01

    Dette er en afrapportering fra den årlige CONTRAST workshop, der i 2007 blev afholdt i Yaoundé, Cameroon.......Dette er en afrapportering fra den årlige CONTRAST workshop, der i 2007 blev afholdt i Yaoundé, Cameroon....

  13. Synchrotron radiation therapy of malignant brain gliomas loaded with an iodinated contrast agent

    International Nuclear Information System (INIS)

    Adam, J.-F.; Elleaume, H.; Joubert, A.; Biston, M.-C.; Charvet, A.-M.; Balosso, J.; Le Bas, J.-F.; Esteve, F.

    2003-01-01

    In conventional radiotherapy, treatment of brain tumors remains a delicate challenge, because the damages to the surrounding normal brain tissue limit the amount of radiation that can be delivered. One strategy to overcome this limitation is to infuse an iodinated contrast agent to the patient during the irradiation, which accumulates in the tumor, through the broken blood brain barrier; and to irradiate with kilovoltage X-rays, in tomographic mode, the tumor being located at the center of rotation and the beam size adjusted to the tumor dimensions. The dose enhancement results from the photoelectric effect on the iodine and from the irradiation geometry. Synchrotron beams, providing high intensity, tunable monochromatic X-rays, are ideal for this treatment. The purpose of this study is to demonstrate in vivo the efficiency of this novel synchrotron radiotherapy modality. Intracranial implantations of 10 5 F98 glioma cells were performed on 17 Fisher 344 rats. 6 rats were untreated controls, 5 received radiotherapy alone (10 Gy in the tumor, single fraction, tomographic irradiation) and 6 the same treatment under a continuous infusion of iodinated contrast agent (2.7 ± 1.05 mg/ml mean tumoral iodine concentration). The beam energy was set at 50 keV. Mean survival times (mean ± SD) were 12.3 ± 0.8, 15.4 ± 2.7 and 18.2 ± 1.3 days, untreated controls, irradiated without iodine, irradiated with iodine, respectively. The median survival times were 12.5, 15 and 18 days respectively, which corresponds to increase life spans of 20% and 44% for the rats irradiated without or with iodine respectively. The rats, which receive contrast agent before therapy survived significantly longer than the ones, which received radiotherapy alone (p=0.04). These preliminary results are encouraging and deserve further investigations. Synchrotron radiation could be a powerful tool for brain tumor radiation therapy

  14. In vivo comparison of tantalum, tungsten, and bismuth enteric contrast agents to complement intravenous iodine for double-contrast dual-energy CT of the bowel.

    Science.gov (United States)

    Rathnayake, Samira; Mongan, John; Torres, Andrew S; Colborn, Robert; Gao, Dong-Wei; Yeh, Benjamin M; Fu, Yanjun

    2016-07-01

    To assess the ability of dual-energy CT (DECT) to separate intravenous contrast of bowel wall from intraluminal contrast, we scanned 16 rabbits on a clinical DECT scanner: n = 3 using only iodinated intravenous contrast, and n = 13 double-contrast enhanced scans using iodinated intravenous contrast and experimental enteric non-iodinated contrast agents in the bowel lumen (five bismuth, four tungsten, and four tantalum based). Representative image pairs from conventional CT images and DECT iodine density maps of small bowel (116 pairs from 232 images) were viewed by four abdominal imaging attending radiologists to independently score each comparison pair on a visual analog scale (-100 to +100%) for (1) preference in small bowel wall visualization and (2) preference in completeness of intraluminal enteric contrast subtraction. Median small bowel wall visualization was scored 39 and 42 percentage points (95% CI 30-44% and 36-45%, both p bismuth contrast. Median completeness of intraluminal enteric contrast subtraction in double-contrast DECT iodine density maps was scored 28 and 29 percentage points (95% CI 15-31% and 28-33%, both p bismuth contrast. Results suggest that in vivo double-contrast DECT with iodinated intravenous and either tantalum- or tungsten-based enteric contrast provides better visualization of small bowel than conventional CT. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Impact of acoustic pressure on ambient pressure estimation using ultrasound contrast agent

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup; Jensen, Jørgen Arendt

    2010-01-01

    Local blood pressure measurements provide important information on the state of health of organs in the body and can be used to diagnose diseases in the heart, lungs, and kidneys. This paper presents an approach for investigating the ambient pressure sensitivity of a contrast agent using diagnostic...... ultrasound. The experimental setup resembles a realistic clinical setup utilizing a single array transducer for transmit and receive. The ambient pressure sensitivity of SonoVue (Bracco, Milano, Italy) was measured twice using two different acoustic driving pressures, which were selected based...

  16. Contrast agent free detection of bowel perforation using chlorophyll derivatives from food plants

    Science.gov (United States)

    Han, Jung Hyun; Jo, Young Goun; Kim, Jung Chul; Lee, Jee-Bum; Kim, Yong-Chul; Kang, Hoonsoo; Hwang, In-Wook

    2016-01-01

    Chlorophylls occur abundantly in food plants and show bright emission bands at long-wavelength regions (∼675 and ∼720 nm) compared to the autofluorescence of animal organs and peritoneal fluids. The use of these emissions as biomarkers for monitoring bowel perforation with a modality that does not involve synthetic contrast agents seems promising. To validate this, we measured the fluorescence spectra of rat organs, human peritoneal and intestinal fluids, and human intestinal fluids diluted with physiological saline. The developed technique showed a high detection sensitivity (∼50 ppm) under irrigation for abdominal surgery, highlighting the potential of this tool in the surgical setting.

  17. Relaxivity of blood pool contrast agent depends on the host tissue as suggested by semianalytical simulations

    DEFF Research Database (Denmark)

    Jensen, Birgitte Fuglsang; Østergaard, Leif; Kiselev, Valerij G

    Concentration of MRI contrast agents (CA) is commonly determined indirectly using their relaxation effect. In quantitative perfusion studies, the change in the relaxation following a bolus passage is converted into concentrations assuming identical relaxivities for tissue and blood. Simulations...... presented in this study demonstrate that the relaxivity of blood pool CA depends significantly on both the host tissue and the pulse sequence, in agreement with previous experiments. In particular, the relaxation effect of Gd-based CA in brain tissues is several-fold larger than in bulk blood. The results...

  18. Chitosan-coated nickel-ferrite nanoparticles as contrast agents in magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Tanveer [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Department of Physics, Abdul Wali Khan University, Mardan (Pakistan); Bae, Hongsub; Iqbal, Yousaf [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Rhee, Ilsu, E-mail: ilrhee@knu.ac.kr [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Hong, Sungwook [Division of Science Education, Daegu University, Gyeongsan 712-714 (Korea, Republic of); Chang, Yongmin; Lee, Jaejun [Department of Diagnostic Radiology, College of Medicine, Kyungpook National University and Hospital, Daegu 700-721 (Korea, Republic of); Sohn, Derac [Department of Physics, Hannam University, Daejon (Korea, Republic of)

    2015-05-01

    We report evidence for the possible application of chitosan-coated nickel-ferrite (NiFe{sub 2}O{sub 4}) nanoparticles as both T{sub 1} and T{sub 2} contrast agents in magnetic resonance imaging (MRI). The coating of nickel-ferrite nanoparticles with chitosan was performed simultaneously with the synthesis of the nickel-ferrite nanoparticles by a chemical co-precipitation method. The coated nanoparticles were cylindrical in shape with an average length of 17 nm and an average width of 4.4 nm. The bonding of chitosan onto the ferrite nanoparticles was confirmed by Fourier transform infrared spectroscopy. The T{sub 1} and T{sub 2} relaxivities were 0.858±0.04 and 1.71±0.03 mM{sup −1} s{sup −1}, respectively. In animal experimentation, both a 25% signal enhancement in the T{sub 1}-weighted mage and a 71% signal loss in the T{sub 2}-weighted image were observed. This demonstrated that chitosan-coated nickel-ferrite nanoparticles are suitable as both T{sub 1} and T{sub 2} contrast agents in MRI. We note that the applicability of our nanoparticles as both T{sub 1} and T{sub 2} contrast agents is due to their cylindrical shape, which gives rise to both inner and outer sphere processes of nanoparticles. - Highlights: • Chitosan-coated nickel-ferrite (Ni-Fe{sub 2}O{sub 4}) nanoparticles were synthesized in an aqueous system by chemical co-precipitation. • The characterization of bare and chitosan-coated nanoparticles were performed using various analytical tools, such as TEM, FTIR, XRD, and VMS. • We evaluated the coated particles as potential T{sub 1} and T{sub 2} contrast agents for MRI by measuring T{sub 1} and T{sub 2} relaxation times as a function of iron concentration. • Both T{sub 1} and T{sub 2} effects were also observed in animal experimentation.

  19. Gaucher disease in the liver on hepatocyte specific contrast agent enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ayyala, Rama S. [Morgan Stanley Children' s Hospital, Department of Radiology, Columbia University Medical Center, New York, NY (United States); Teot, Lisa A. [Boston Children' s Hospital, Department of Pathology, Harvard Medical School, Boston, MA (United States); Perez Rossello, Jeanette M. [Boston Children' s Hospital, Department of Radiology, Harvard Medical School, Boston, MA (United States)

    2017-04-15

    Gaucher disease is a hereditary lipid storage disorder that affects the enzyme beta glucocerebrosidase, causing accumulation of glucocerebroside in macrophages of the reticuloendothelial system. Accumulation can occur in the liver and spleen, manifesting as hepatosplenomegaly, as well as within the bone marrow. Hepatic involvement is usually diffuse but can occasionally manifest as focal liver lesions. We present a case of a 2-year-old boy with Gaucher disease and an infiltrating liver lesion detected on imaging, which was pathologically shown to be focal changes related to the disease. Imaging characteristics of this lesion using hepatocyte specific contrast agent enhanced MRI, which have not been previously discussed in the literature, are described. (orig.)

  20. Gaucher disease in the liver on hepatocyte specific contrast agent enhanced MR imaging

    International Nuclear Information System (INIS)

    Ayyala, Rama S.; Teot, Lisa A.; Perez Rossello, Jeanette M.

    2017-01-01

    Gaucher disease is a hereditary lipid storage disorder that affects the enzyme beta glucocerebrosidase, causing accumulation of glucocerebroside in macrophages of the reticuloendothelial system. Accumulation can occur in the liver and spleen, manifesting as hepatosplenomegaly, as well as within the bone marrow. Hepatic involvement is usually diffuse but can occasionally manifest as focal liver lesions. We present a case of a 2-year-old boy with Gaucher disease and an infiltrating liver lesion detected on imaging, which was pathologically shown to be focal changes related to the disease. Imaging characteristics of this lesion using hepatocyte specific contrast agent enhanced MRI, which have not been previously discussed in the literature, are described. (orig.)

  1. Responsive magnetic resonance imaging contrast agents as chemical sensors for metals in biology and medicine.

    Science.gov (United States)

    Que, Emily L; Chang, Christopher J

    2010-01-01

    This tutorial review highlights progress in the development of responsive magnetic resonance imaging (MRI) contrast agents for detecting and sensing biologically relevant metal ions. Molecular imaging with bioactivatable MRI indicators offers a potentially powerful methodology for studying the physiology and pathology of metals by capturing dynamic three-dimensional images of living systems for research and clinical applications. This emerging area at the interface of inorganic chemistry and the life sciences offers a broad palette of opportunities for researchers with interests ranging from coordination chemistry and spectroscopy to supramolecular chemistry and molecular recognition to metals in biology and medicine.

  2. Iron oxide nanoparticles for use in contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Oliveira, Elisa M.N. de; Rocha, Maximiliano S. da; Caimi, Priscila de A.; Basso, Nara R. de S.; Zanini, Mara L.; Papaleo, Ricardo M.

    2015-01-01

    In this work were carried out synthesis of iron oxide nanoparticles coated with dextran, comparing the results of using different concentrations of dextran, iron salts, temperature and reaction time. The compounds were analyzed by DLS, XRD, TGA, TEM, FTIR, Zeta Potential and relaxivity. Nanoparticles with dispersion around 10-15 nm and average hydrodynamic diameters of 16-50 nm, with superparamagnetic behavior were obtained. The ratio of the relaxivities (r2/r1) in aqueous solutions was 5.30, close to value of the commercially available iron oxide contrast agents. (author)

  3. Magnetosomes used as biogenic MRI contrast agent for molecular imaging of glioblastoma model

    International Nuclear Information System (INIS)

    Boucher, Marianne

    2016-01-01

    This work takes place in the context of molecular imaging, which aims at tailoring medical treatments and therapies to the individual context by revealing molecular or cellular phenomenon of medical interest in the less invasive manner. In particular, it can be achieved with MRI molecular imaging using engineered iron-oxide contrast agent.This PhD thesis focuses on the study of a new class of iron-oxide contrast agent for high field MRI. Indeed, magnetosomes are natural iron-oxide vesicles produced by magneto-tactic bacteria. These bacteria synthesized such magnetic vesicles and ordered them like a nano-compass in order to facilitate their navigation in sediments. This explains why magnetosomes are awarded with tremendous magnetic properties: around 50 nm, mono-crystalline, single magnetic domain and high saturation magnetization. Furthermore, a wide variety of bacterial strains exist in nature and size and shape of magnetosomes are highly stable within strain and can be very different between strains. Finally, magnetosomes are naturally coated with a bi-lipidic membrane whose content is genetically determined. Lately, researchers have unravelled magnetosomes membrane protein contents, opening the way to create functionalized magnetosomes thanks to fusion of the gene coding for a protein of interest with the gene coding for an abundant protein at magnetosomes membrane.A new alternative path using living organisms to tackle the production of engineered high efficiency molecular imaging probes have been investigated with magneto-tactic bacteria in this PhD. The production and engineering of magnetosomes have been carried out by our partner, the Laboratoire de Bio-energetique Cellulaire (LBC, CEA Cadarache), and will be presented and discussed. We then characterized magnetosomes as contrast agent for high field MRI. We showed they present very promising contrasting properties in vitro, and assessed this observation in vivo by establishing they can be used as efficient

  4. Contrast-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Vogl, T.J.; Hoffmann, Y.; Muehler, A.; Felix, R.

    1994-01-01

    Magnetic resonance angiography (MRA) protocols are based on standard sequence protocols like time of flight MRA, which evaluates inflowing spins. This technique is limited by a variety of artifacts like the saturation artifact via turbulent blood flow. Contrast media diminish these artifacts like extracellular agents and blood-pool contrast media. The clinical value of the contrast-enhanced MRA for cerebral pathologies is based on the use of the paramagnetic contrast agent Gd-DTPA. For extracerebral diseases this technique is restricted because of the simultaneous visualization of both arterial and venous vascular territorities. Occult venous sinus thrombosis or AV malformations are clinical essential indications for the use of C-MRA. Experimental data prove the excellent contrast abilities of blood-pool agents like Gd-DTPA-polylysin or Gd-DTPA-albumin, which demonstrate long intravascular persistence and retarded excretion. (orig.) [de

  5. Ultrasound molecular imaging of ovarian cancer with CA-125 targeted nanobubble contrast agents.

    Science.gov (United States)

    Gao, Yong; Hernandez, Christopher; Yuan, Hai-Xia; Lilly, Jacob; Kota, Pavan; Zhou, Haoyan; Wu, Hanping; Exner, Agata A

    2017-10-01

    Ultrasound is frequently utilized in diagnosis of gynecologic malignancies such as ovarian cancer. Because epithelial ovarian cancer (EOC) is often characterized by overexpression of cancer antigen 125 (CA-125), ultrasound contrast agents able to target this molecular signature could be a promising complementary strategy. In this work, we demonstrate application of CA-125-targeted echogenic lipid and surfactant-stabilized nanobubbles imaged with standard clinical contrast harmonic ultrasound for imaging of CA-125 positive OVCAR-3 tumors in mice. Surface functionalization of the nanobubbles with a CA-125 antibody achieved rapid significantly (P CA-125 negative SKOV-3 tumors. Targeted nanobubbles also exhibited increased tumor retention and prolonged echogenicity compared to untargeted nanobubbles. Data suggest that ultrasound molecular imaging using CA-125 antibody-conjugated nanobubbles may contribute to improved diagnosis of EOC. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Intravascular "mulberry-like" bodies

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Klebe, J G; Henriques, U V

    1988-01-01

    Intravascular "mulberry-like" bodies in a stillborn female infant with moderate maceration are reported. The histogenesis of these structures is discussed based on light-microscopic, immunohistochemical and ultrastructural findings. No demonstrable causal relation between the intravascular lesion...... and fetal death was found, the cause of death being attributed to intrauterine asphyxia. It is concluded, that intravascular "mulberry-bodies" most likely represent artifacts due to red blood cell autolysis....

  7. Contrast agent based on nano-emulsion for targeted biomedical imaging

    International Nuclear Information System (INIS)

    Attia, Mohamed

    2016-01-01

    X-ray imaging agents are essential in combination with X-ray computed tomography to improve contrast enhancement aiming at providing complete visualization of blood vessels and giving structural and functional information on lesions allowing the detection of a tumor. As well as it is fundamental tool to discriminate between healthy cells and pathogens. We successfully limit the problems presented in commercial X-ray contrast agents like poor contrasting in Fenestra VC associated with short blood circulation time and to avoid rapid renal elimination from the body as found in Xenetix (Iobitriol). We developed nontoxic and blood pool iodine-containing nano-emulsion contrast agents serving in preclinical X-ray μ-CT imaging such as, a- Tocopherol (vitamin E), Cholecalciferol (vitamin D3), Castor oil, Capmul MCMC8 oil and oleic acid. Those formulated nano emulsions were prepared by low energy spontaneous emulsification technic with slight modification for each platform. They showed new specific features rendering them promising agents in in vivo experiments as improving the balance between the efficacy and the toxicity of targeted therapeutic interventions. We investigate the effect of size and the chemical composition of the nanoparticles on their biodistribution, pharmacokinetics and toxicity. They demonstrated that the chemical structures of the droplet's cores have significant role in targeting for example vitamin E was mainly accumulated in liver and castor oil formulation was passively accumulated in spleen explaining the proof-of-concept of EPR effect. On the other hand, two different platform sizes of Cholecalciferol molecule revealing that no real impact on the pharmacokinetics and biodistribution but presented remarkable effect on the toxicity. Of particular interest is studying the effect of the surface charge of nanoparticles on their biodistribution, this is why oleic acid nano-emulsion was selected to proceed this study by presence of amphiphilic

  8. Transdermal drug delivery aided by an ultrasound contrast agent: an in vitro experimental study.

    Science.gov (United States)

    Park, Donghee; Yoon, Jinhee; Park, Jingam; Jung, Byungjo; Park, Hyunjin; Seo, Jongbum

    2010-02-11

    Sonophoresis temporarily increases skin permeability such that medicine can be delivered transdermally. Cavitation is believed to be the predominant mechanism in sonophoresis. In this study, an ultrasound contrast agent (UCA) strategy was adopted instead of low frequency ultrasound to assure that cavitation occurred, and the efficacy of sonophoresis with UCA was quantitatively analyzed by optical measurements. The target drug used in this study was 0.1 % Definity(R) in 70% glycerol, which was delivered into porcine skin samples. Glycerol was used because it is an optical clearing agent, and the efficiency of glycerol delivery could be analyzed with optical measurements. The applied acoustic pressure was approximately 600 kPa at 1 MHz ultrasound with a 10% duty cycle for 60 minutes. Experimental results indicated that the measured relative contrast (RC) after sonophoresis with UCA was approximately 80% higher than RC after sonophoresis without UCA. In addition, the variance of RC was also reduced by more than 50% with the addition of a UCA. The use of a UCA appeared to increase cavitation, demonstrating that the use of a UCA can be effective in transdermal drug delivery (TDD).

  9. A novel technology: microfluidic devices for microbubble ultrasound contrast agent generation.

    Science.gov (United States)

    Lin, Hangyu; Chen, Junfang; Chen, Chuanpin

    2016-09-01

    Microbubbles are used as ultrasound contrast agents, which enhance ultrasound imaging techniques. In addition, microbubbles currently show promise in disease therapeutics. Microfluidic devices have increased the ability to produce microbubbles with precise size, and high monodispersity compared to microbubbles created using traditional methods. This paper will review several variations in microfluidic device structures used to produce microbubbles as ultrasound contrast agents. Microfluidic device structures include T-junction, and axisymmetric and asymmetric flow-focusing. These devices have made it possible to produce microbubbles that can enter the vascular space; these microbubbles must be less than 10 μm in diameter and have high monodispersity. For different demands of microbubbles production rate, asymmetric flow-focusing devices were divided into individual and integrated devices. In addition, asymmetric flow-focusing devices can produce double layer and multilayer microbubbles loaded with drug or biological components. Details on the mechanisms of both bubble formation and device structures are provided. Finally, microfluidically produced microbubble acoustic responses, microbubble stability, and microbubble use in ultrasound imaging are discussed.

  10. Vascular imaging with contrast agent in hard and soft tissues using microcomputed-tomography.

    Science.gov (United States)

    Blery, P; Pilet, P; Bossche, A Vanden-; Thery, A; Guicheux, J; Amouriq, Y; Espitalier, F; Mathieu, N; Weiss, P

    2016-04-01

    Vascularization is essential for many tissues and is a main requisite for various tissue-engineering strategies. Different techniques are used for highlighting vasculature, in vivo and ex vivo, in 2-D or 3-D including histological staining, immunohistochemistry, radiography, angiography, microscopy, computed tomography (CT) or micro-CT, both stand-alone and synchrotron system. Vascularization can be studied with or without a contrast agent. This paper presents the results obtained with the latest Skyscan micro-CT (Skyscan 1272, Bruker, Belgium) following barium sulphate injection replacing the bloodstream in comparison with results obtained with a Skyscan In Vivo 1076. Different hard and soft tissues were perfused with contrast agent and were harvested. Samples were analysed using both forms of micro-CT, and improved results were shown using this new micro-CT. This study highlights the vasculature using micro-CT methods. The results obtained with the Skyscan 1272 are clearly defined compared to results obtained with Skyscan 1076. In particular, this instrument highlights the high number of small vessels, which were not seen before at lower resolution. This new micro-CT opens broader possibilities in detection and characterization of the 3-D vascular tree to assess vascular tissue engineering strategies. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  11. Characterization of colloidal manganese hydroxylapatite: A potential magnetic resonance contrast agent

    Science.gov (United States)

    Dorshow, Richard B.; Kofi Adzamli, I.; Nosco, Dennis L.; Joslin, Frederick L.

    1996-03-01

    Particulate contrast agents for blood pool imaging need to be constructed with the appropriate particle size distribution (PSD), and need to be resistant to opsonization. Hence, the PSD of an aqueous colloidal suspension of polyethylene glycol (PEG)-stabilized manganese hydroxylapatite (potentially useful as a magnetic resonance contrast agent for blood pool imaging) has been investigated as a function of PEG concentration and molecular weight. At low PEG concentrations, dynamic light scattering (DLS) and sedimentation field flow fractionation measurements yield a broad PSD, with the largest particle diameters near 100nm. Flow field flow fractionation (FlFFF) measurements, however, yield a distinct population near 10nm, which is not readily detectable by the other two techniques. As the PEG concentration is increased, the PSD shifts toward the lower size population. At the highest PEG concentration employed, only particles of diameter 10nm remain, verified by both FlFFF and DLS. Thus, the search for an optimum PSD for blood pool imaging is facilitated by choice of PEG molecular weight and concentration, and by employing complementary use of light scattering and field flow fractionation techniques.

  12. High Relaxivity Gadolinium Hydroxypyridonate-Viral Capsid Conjugates: Nano-sized MRI Contrast Agents

    Energy Technology Data Exchange (ETDEWEB)

    Meux, Susan C.; Datta, Ankona; Hooker, Jacob M.; Botta, Mauro; Francis, Matthew B.; Aime, Silvio; Raymond, Kenneth N.

    2007-08-29

    High relaxivity macromolecular contrast agents based on the conjugation of gadolinium chelates to the interior and exterior surfaces of MS2 viral capsids are assessed. The proton nuclear magnetic relaxation dispersion (NMRD) profiles of the conjugates show up to a five-fold increase in relaxivity, leading to a peak relaxivity (per Gd{sup 3+} ion) of 41.6 mM{sup -1}s{sup -1} at 30 MHz for the internally modified capsids. Modification of the exterior was achieved through conjugation to flexible lysines, while internal modification was accomplished by conjugation to relatively rigid tyrosines. Higher relaxivities were obtained for the internally modified capsids, showing that (1) there is facile diffusion of water to the interior of capsids and (2) the rigidity of the linker attaching the complex to the macromolecule is important for obtaining high relaxivity enhancements. The viral capsid conjugated gadolinium hydroxypyridonate complexes appear to possess two inner-sphere water molecules (q = 2) and the NMRD fittings highlight the differences in the local motion for the internal ({tau}{sub RI} = 440 ps) and external ({tau}{sub RI} = 310 ps) conjugates. These results indicate that there are significant advantages of using the internal surface of the capsids for contrast agent attachment, leaving the exterior surface available for the installation of tissue targeting groups.

  13. A biomimetic Au@BSA-DTA nanocomposites-based contrast agent for computed tomography imaging.

    Science.gov (United States)

    Zhao, Wenjing; Wang, Zhiming; Chen, Lina; Huang, Chusen; Huang, Yuankui; Jia, Nengqin

    2017-09-01

    Early detection of cancer is increasingly important for being considered to increase the survival rate in the treatment process. The past decades years have witnessed the great progress in the biological detection application of gold nanoparticles. Herein, we reported a facile one-pot synthesis process to obtain gold nanoparticles (Au@BSA) with bovine serum albumin (BSA) as a biotemplate following with conjugation of diatrizoic acid (DTA) for a potential X-ray computed tomography (CT) imaging contrast agent (Au@BSA-DTA). The as-prepared biomimetic material was characterized systematically by several techniques. It was shown that the prepared biomaterial is colloid stable under the tested range of pH and temperature. The cell cytotoxicity assay, hemolytic assay and cell morphology observation showed that Au@BSA-DTA has good biocompatibility and hemocompatibility at a concentration of Au even up to 80μg/mL. Besides, the biomimetic material Au@BSA-DTA with double radiodense elements of Au and iodine displayed much stronger CT imaging effect compared with the traditional small molecule contrast agents, which paves the potential clinical application in cancer early diagnosis. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Fe3O4-based PLGA nanoparticles as MR contrast agents for the detection of thrombosis.

    Science.gov (United States)

    Liu, Jia; Xu, Jie; Zhou, Jun; Zhang, Yu; Guo, Dajing; Wang, Zhigang

    2017-01-01

    Thrombotic disease is a great threat to human health, and early detection is particularly important. Magnetic resonance (MR) molecular imaging provides noninvasive imaging with the potential for early disease diagnosis. In this study, we developed Fe 3 O 4 -based poly(lactic- co -glycolic acid) (PLGA) nanoparticles (NPs) surface-modified with a cyclic Arg-Gly-Asp (cRGD) peptide as an MR contrast agent for the detection of thrombosis. The physical and chemical characteristics, biological toxicity, ability to target thrombi, and biodistribution of the NPs were studied. The Fe 3 O 4 -PLGA-cRGD NPs were constructed successfully, and hematologic and pathologic assays indicated no in vivo toxicity of the NPs. In a rat model of FeCl 3 -induced abdominal aorta thrombosis, the NPs readily and selectively accumulated on the surface of the thrombosis and under vascular endothelial cells ex vivo and in vivo. In the in vivo experiment, the biodistribution of the NPs suggested that the NPs might be internalized by the macrophages of the reticuloendothelial system in the liver and the spleen. The T2 signal decreased at the mural thrombus 10 min after injection and then gradually increased until 50 min. These results suggest that the NPs are suitable for in vivo molecular imaging of thrombosis under high shear stress conditions and represent a very promising MR contrast agent for sensitive and specific detection of thrombosis.

  15. Measurement of volumetric flow rates with ultrasonic contrast agents using a depletion method

    Science.gov (United States)

    Ketterling, Jeffrey A.; Deng, Cheri X.; Lizzi, Frederic L.; Silverman, Ronald H.; Coleman, D. Jackson

    2002-05-01

    A high-intensity focused transducer was used to deplete a small, well-defined volume of contrast agent flow in a small diameter tube. The depleted volume was probed both confocally and downstream with a 7.5-MHz focused diagnostic transducer. The depletion volume was found from theoretical calculations of the acoustic beam profile. Volume flow rates were then calculated by measuring the time required for the depleted volume to pass the diagnostic transducer. Additionally, a beam with known sidelobe spacing can give information about the flow velocity if the high-intensity transducer exposure is short and the sidelobes form spatially separated subdepletion regions. A 4.7-MHz ``strip electrode'' high-intensity transducer with 0.5-mm sidelobe spacing was used to study the flow velocity in dialysis tubing with a 3.1-mm outer diameter. Flow of known volume velocity was generated with a syringe pump. Both Optison and Albunex contrast agents were used. Experimental flow velocities were in excellent agreement with the known flow measurement.

  16. Effect on renal function of an iso-osmolar contrast agent in patients with monoclonal gammopathies

    International Nuclear Information System (INIS)

    Preda, Lorenzo; Agazzi, Alberto; Martinelli, Giovanni; Raimondi, Sara; Lanfranchi, Carla Federica; Passerini, Rita; Calvetta, Albania; Bellomi, Massimo

    2011-01-01

    To assess the safety of the non-ionic iso-osmolar contrast agent iodixanol on renal function in patients with monoclonal gammopathies undergoing CT. We explored the effect of iodixanol on renal function in 30 patients with monoclonal gammopathies and 20 oncological patients with a normal electrophoretic profile (control group). The parameters used to estimate renal function were: serum creatinine, eGFR (determined 24 h before and 48 h after the administration of iodixanol), and urinary excretion of Neutrophil Gelatinase-Associated Lipocalin (NGAL) determined 2 h and 24 h after. Serum creatinine was also determined 1 month after the administration of iodixanol. No significant increase in serum creatinine values were observed in the monoclonal gammopathies group and in 19/20 patients in the control group. Only 1 patient in the control group developed a transient contrast agent-induced nephropathy. We found no statistically significant difference between the two groups regarding the percentage variation from baseline values of serum creatinine, creatinine clearance, NGAL 2 h after, and eGFR. Whereas NGAL at 24 h showed a statistically significant increase in patients with Monoclonal gammopathies. The use of iodixanol appears to be safe in patients with monoclonal gammopathies and an eGFR ≥ 60 ml/min/1.73 mq. (orig.)

  17. Effect on renal function of an iso-osmolar contrast agent in patients with monoclonal gammopathies

    Energy Technology Data Exchange (ETDEWEB)

    Preda, Lorenzo [Division of Radiology, European Institute of Oncology, IRCCS, Milan (Italy); Agazzi, Alberto; Martinelli, Giovanni [Division of Haematology, European Institute of Oncology, IRCCS, Milan (Italy); Raimondi, Sara [Division of Epidemiology and Biostatistics, European Institute of Oncology, IRCCS, Milan (Italy); University of Milan, Department of Occupational Medicin ' ' Clinica del Lavoro Luigi Devoto' ' Section of Medical Statistics and Biometry ' ' GA Maccacaro' ' , Milan (Italy); Lanfranchi, Carla Federica [University of Milan, IRCCS, School of Medicine, Milan (Italy); Passerini, Rita [Unit of Laboratory Medicine, European Institute of Oncology, IRCCS, Milan (Italy); Calvetta, Albania [Nephrology and Dialysis Unit, Istituto Clinico Humanitas, IRCCS, Rozzano, Milan (Italy); Bellomi, Massimo [Division of Radiology, European Institute of Oncology, IRCCS, Milan (Italy); University of Milan, IRCCS, School of Medicine, Milan (Italy)

    2011-01-15

    To assess the safety of the non-ionic iso-osmolar contrast agent iodixanol on renal function in patients with monoclonal gammopathies undergoing CT. We explored the effect of iodixanol on renal function in 30 patients with monoclonal gammopathies and 20 oncological patients with a normal electrophoretic profile (control group). The parameters used to estimate renal function were: serum creatinine, eGFR (determined 24 h before and 48 h after the administration of iodixanol), and urinary excretion of Neutrophil Gelatinase-Associated Lipocalin (NGAL) determined 2 h and 24 h after. Serum creatinine was also determined 1 month after the administration of iodixanol. No significant increase in serum creatinine values were observed in the monoclonal gammopathies group and in 19/20 patients in the control group. Only 1 patient in the control group developed a transient contrast agent-induced nephropathy. We found no statistically significant difference between the two groups regarding the percentage variation from baseline values of serum creatinine, creatinine clearance, NGAL 2 h after, and eGFR. Whereas NGAL at 24 h showed a statistically significant increase in patients with Monoclonal gammopathies. The use of iodixanol appears to be safe in patients with monoclonal gammopathies and an eGFR {>=} 60 ml/min/1.73 mq. (orig.)

  18. Targeted Nanodiamonds as Phenotype Specific Photoacoustic Contrast Agents for Breast Cancer

    Science.gov (United States)

    Zhang, Ti; Cui, Huizhong; Fang, Chia-Yi; Cheng, Kun; Yang, Xinmai; Chang, Huan-Cheng; Forrest, M. Laird

    2015-01-01

    Aim The aim is to develop irradiated nanodiamonds (INDs) as a molecularly-targeted contrast agent for high resolution and phenotype-specific detection of breast cancer with photoacoustic (PA) imaging. Materials & Methods The surface of acid treated radiation-damaged nanodiamonds was grafted with polyethylene glycol (PEG) to improve its stability and circulation time in blood, followed by conjugation to an anti-Human epidermal growth factor receptor-2 (HER2) peptide (KCCYSL) with a final nanoparticle size of ca. 92 nm. Immunocompetent mice bearing orthotopic HER2 positive or negative tumors were administered INDs and PA imaged using an 820-nm near infrared laser. Results PA images demonstrated that INDs accumulate in tumors and completely delineated the entire tumor within 10 hours. HER2 targeting significantly enhanced imaging of HER2-positive tumors. Pathological examination demonstrated INDs are non-toxic. Conclusions PA technology is adaptable to low-cost bedside medicine, and with new contrast agents described herein, PA can achieve high resolution (sub-mm) and phenotype specific monitoring of cancer growth. PMID:25723091

  19. X-ray Scatter Imaging of Hepatocellular Carcinoma in a Mouse Model Using Nanoparticle Contrast Agents

    Science.gov (United States)

    Rand, Danielle; Derdak, Zoltan; Carlson, Rolf; Wands, Jack R.; Rose-Petruck, Christoph

    2015-01-01

    Hepatocellular carcinoma (HCC) is one of the most common malignant tumors worldwide and is almost uniformly fatal. Current methods of detection include ultrasound examination and imaging by CT scan or MRI; however, these techniques are problematic in terms of sensitivity and specificity, and the detection of early tumors (x-ray imaging technique called Spatial Frequency Heterodyne Imaging (SFHI) for the early detection of HCC. SFHI uses x-rays scattered by an object to form an image and is more sensitive than conventional absorption-based x-radiography. We show that tissues labeled in vivo with gold nanoparticle contrast agents can be detected using SFHI. We also demonstrate that directed targeting and SFHI of HCC tumors in a mouse model is possible through the use of HCC-specific antibodies. The enhanced sensitivity of SFHI relative to currently available techniques enables the x-ray imaging of tumors that are just a few millimeters in diameter and substantially reduces the amount of nanoparticle contrast agent required for intravenous injection relative to absorption-based x-ray imaging. PMID:26511147

  20. Experimental investigations of nonlinearities and destruction mechanisms of an experimental phospholipid-based ultrasound contrast agent.

    Science.gov (United States)

    Casciaro, Sergio; Palmizio Errico, Rosa; Errico, Rosa Palmizio; Conversano, Francesco; Demitri, Christian; Distante, Alessandro

    2007-02-01

    We sought to characterize the acoustical behavior of the experimental ultrasound contrast agent BR14 by determining the acoustic pressure threshold above which nonlinear oscillation becomes significant and investigating microbubble destruction mechanisms. We used a custom-designed in vitro setup to conduct broadband attenuation measurements at 3.5 MHz varying acoustic pressure (range, 50-190 kPa). We also performed granulometric analyses on contrast agent solutions to accurately measure microbubble size distribution and to evaluate insonification effects. Attenuation did not depend on acoustic pressure less than 100 kPa, indicating this pressure as the threshold for the appearance of microbubble nonlinear behavior. At the lowest excitation amplitude, attenuation increased during insonification, while, at higher excitation levels, the attenuation decreased over time, indicating microbubble destruction. The destruction rate changed with pressure amplitude suggesting different destruction mechanisms, as it was confirmed by granulometric analysis. Microbubbles showed a linear behavior until 100 kPa, whereas beyond this value significant nonlinearities occurred. Observed destruction phenomena seem to be mainly due to gas diffusion and bubble fragmentation mechanisms.

  1. Gadolinium-based magnetic resonance contrast agents at 7 Tesla: in vitro T1 relaxivities in human blood plasma.

    Science.gov (United States)

    Noebauer-Huhmann, Iris M; Szomolanyi, Pavol; Juras, Vladimír; Kraff, Oliver; Ladd, Mark E; Trattnig, Siegfried

    2010-09-01

    PURPOSE/INTRODUCTION: The aim of this study was to determine the T1 relaxivities (r1) of 8 gadolinium (Gd)-based MR contrast agents in human blood plasma at 7 Tesla, compared with 3 Tesla. Eight commercially available Gd-based MR contrast agents were diluted in human blood plasma to concentrations of 0, 0.25, 0.5, 1, and 2 mmol/L. In vitro measurements were performed at 37 degrees C, on a 7 Tesla and on a 3 Tesla whole-body magnetic resonance imaging scanner. For the determination of T1 relaxation times, Inversion Recovery Sequences with inversion times from 0 to 3500 ms were used. The relaxivities were calculated. The r1 relaxivities of all agents, diluted in human blood plasma at body temperature, were lower at 7 Tesla than at 3 Tesla. The values at 3 Tesla were comparable to those published earlier. Notably, in some agents, a minor negative correlation of r1 with a concentration of up to 2 mmol/L could be observed. This was most pronounced in the agents with the highest protein-binding capacity. At 7 Tesla, the in vitro r1 relaxivities of Gd-based contrast agents in human blood plasma are lower than those at 3 Tesla. This work may serve as a basis for the application of Gd-based MR contrast agents at 7 Tesla. Further studies are required to optimize the contrast agent dose in vivo.

  2. Evaluation of microbubbles as contrast agents for ultrasonography and magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Ling Li

    Full Text Available BACKGROUND: Microbubbles (MBs can serve as an ultrasound contrast agent, and has the potential for magnetic resonance imaging (MRI. Due to the relatively low effect of MBs on MRI, it is necessary to develop new MBs that are more suitable for MRI. In this study, we evaluate the properties of SonoVue® and custom-made Fe(3O(4-nanoparticle-embedded microbubbles (Fe(3O(4-MBs in terms of contrast agents for ultrsonography (US and MRI. METHODOLOGY/PRINCIPAL FINDINGS: A total of 20 HepG2 subcutaneous-tumor-bearing nude mice were randomly assigned to 2 groups (i.e., n = 10 mice each group, one for US test and the other for MRI test. Within each group, two tests were performed for each mouse. The contrast agent for the first test is SonoVue®, and the second is Fe(3O(4-MBs. US was performed using a Technos(MPX US system (Esaote, Italy with a contrast-tuned imaging (CnTI™ mode. MRI was performed using a 7.0T Micro-MRI (PharmaScan, Bruker Biospin GmbH, Germany with an EPI-T(2* sequence. The data of signal-to-noise ratio (SNR from the region-of-interest of each US and MR image was calculated by ImageJ (National Institute of Health, USA. In group 1, enhancement of SonoVue® was significantly higher than Fe(3O(4-MBs on US (P0.05. The SNR analysis of the enhancement process reveals a strong negative correlation in both cases (i.e., SonoVue® r = -0.733, Fe(3O(4-MBs r = -0.903, with P<0.05. CONCLUSIONS: It might be important to change the Fe(3O(4-MBs' shell structure and/or the imagining strategy of US to improve the imaging quality of Fe(3O(4-MBs on US. As an intriguing prospect that can be detected by US and MRI, MBs are worthy of further study.

  3. In vitro evaluation of alternative oral contrast agents for MRI of the gastrointestinal tract

    International Nuclear Information System (INIS)

    Babos, Magor; Schwarcz, Attila; Randhawa, Manjit Singh; Marton, Balazs; Kardos, Lilla; Palko, Andras

    2008-01-01

    Purpose: In vitro evaluation of different materials as potential alternative oral contrast agents for small bowel MRI. Materials and methods: The T1 and T2 relaxation times of rose hip syrup, black currant extract, cocoa, iron-deferoxamine solution and a commonly used oral contrast material (1 mM Gd-DTPA) were determined in vitro at different concentrations on a 1.0 T clinical MR scanner. T1 values were obtained with an inversion prepared spoiled gradient echo sequence. T2 values were obtained using multiple echo sequences. Finally the materials were visualized on T1-, T2- and T2*-weighted MR images. Results: The relaxation times of the undiluted rose hip syrup (T1 = 110 ± 5 ms, T2 = 86 ± 3 ms), black currant extract (T1 = 55 ± 3 ms, T2 = 39 ± 2 ms) and 5 mM iron-deferoxamine solution (T1 = 104 ± 4 ms, T2 = 87 ± 2 ms) were much shorter than for a 1 mM Gd-DTPA solution (T1 = 180 ± 8 ms, T2 = 168 ± 5 ms). Dilution of black currant extract to 30% or a 3 mM iron-deferoxamine solution conducted to T1 relaxation times which are quite comparable to a 1 mM Gd-DTPA solution. Despite its much lower metal content an aqueous cocoa suspension (100 g/L) produced T2 relaxation times (T1 = 360 ± 21 ms, T2 = 81 ± 3 ms) more or less in the same range like the 5 mM iron-deferoxamine solution. Imaging of our in vitro model using clinical sequences allowed to anticipate the T1-, T2- and T2*-depiction of all used substances. Cocoa differed from all other materials with its low to moderate signal intensity on T1- and T2-weighted sequences. While all substances presented a linear 1/T1 and 1/T2 relationship towards concentration, rose hip syrup broke ranks with a disproportionately high increase of relaxation at higher concentrations. Conclusions: Rose hip syrup, black currant extract and iron-deferoxamine solution due to their positive T1 enhancement characteristics and drinkability appear to be valuable oral contrast agents for T1-weighted small bowel MRI. Cocoa with its

  4. Ultrasonic-assisted synthesis of magnetite based MRI contrast agent using cysteine as the biocapping coating

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadi, Reza [Department of Materials Science and Engineering, Sharif University of Technology, P.O. Box 11155-9466, Tehran (Iran, Islamic Republic of); Malek, Mahrooz [Medical Image Centre, Imam Khomeini Hospital, Tehran Medical University, Tehran (Iran, Islamic Republic of); Hosseini, Hamid Reza Madaah [Department of Materials Science and Engineering, Sharif University of Technology, P.O. Box 11155-9466, Tehran (Iran, Islamic Republic of); Shokrgozar, Mohammad Ali [National Cell Bank of Iran, Pasteur Institute of Iran, Tehran (Iran, Islamic Republic of); Oghabian, Mohammad Ali [Research Centre for Sciences and Technology in Medicine, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Masoudi, Afshin [Department of Materials Science and Engineering, Sharif University of Technology, P.O. Box 11155-9466, Tehran (Iran, Islamic Republic of); Gu Ning; Zhang Yu [Jiangsu Key Laboratory of Biomaterials and Devices, Nanjing (China)

    2011-12-15

    Highlights: Black-Right-Pointing-Pointer We used cysteine as surfactant to synthesize stable magnetite-based ferrofluids. Black-Right-Pointing-Pointer pH increase from 11 to 12 led to particle size decrease from 19.58 to 10.02 nm. Black-Right-Pointing-Pointer Cytotoxicity assay showed that synthesized particles were biocompatible. Black-Right-Pointing-Pointer MRI results showed that magnetite particles were accumulated in lymph nodes. - Abstract: Magnetite nanoparticles (mean particle size ranging from 10 to 20 nm) were prepared by a biomolecule-assisted solution-phase approach under ultrasonic irradiation. Cysteine was used as the capping agent in the solution. The results show that cysteine could be an efficient biocapping agent in producing Fe{sub 3}O{sub 4} nanoparticles. The crystal structure and magnetic properties of the nanoparticles were characterized by XRD and VSM techniques, respectively. FT-IR was used to investigate the presence of cysteine on the nanoparticles surface. The influence of pH value of the solution on the size distribution and hydrodynamic size of nanoparticles were studied by TEM and DLS methods, respectively. The MTT assay performed by incubation of L929 cells, showed the good biocompability of synthesized ferrofluids. In vitro T1 and T2 relaxivity measurements along with in vivo studies, which were conducted on rats, demonstrate that synthesized nanoparticles are applicable as the contrast agents, especially for imaging of the lymphatic system.

  5. Ultrasonic-assisted synthesis of magnetite based MRI contrast agent using cysteine as the biocapping coating

    International Nuclear Information System (INIS)

    Ahmadi, Reza; Malek, Mahrooz; Hosseini, Hamid Reza Madaah; Shokrgozar, Mohammad Ali; Oghabian, Mohammad Ali; Masoudi, Afshin; Gu Ning; Zhang Yu

    2011-01-01

    Highlights: ► We used cysteine as surfactant to synthesize stable magnetite-based ferrofluids. ► pH increase from 11 to 12 led to particle size decrease from 19.58 to 10.02 nm. ► Cytotoxicity assay showed that synthesized particles were biocompatible. ► MRI results showed that magnetite particles were accumulated in lymph nodes. - Abstract: Magnetite nanoparticles (mean particle size ranging from 10 to 20 nm) were prepared by a biomolecule-assisted solution-phase approach under ultrasonic irradiation. Cysteine was used as the capping agent in the solution. The results show that cysteine could be an efficient biocapping agent in producing Fe 3 O 4 nanoparticles. The crystal structure and magnetic properties of the nanoparticles were characterized by XRD and VSM techniques, respectively. FT-IR was used to investigate the presence of cysteine on the nanoparticles surface. The influence of pH value of the solution on the size distribution and hydrodynamic size of nanoparticles were studied by TEM and DLS methods, respectively. The MTT assay performed by incubation of L929 cells, showed the good biocompability of synthesized ferrofluids. In vitro T1 and T2 relaxivity measurements along with in vivo studies, which were conducted on rats, demonstrate that synthesized nanoparticles are applicable as the contrast agents, especially for imaging of the lymphatic system.

  6. Development of nanostars as a biocompatible tumor contrast agent: toward in vivo SERS imaging

    Directory of Open Access Journals (Sweden)

    D’Hollander A

    2016-08-01

    Full Text Available Antoine D’Hollander,1–3 Evelien Mathieu,1,4 Hilde Jans,1 Greetje Vande Velde,2,3 Tim Stakenborg,1 Pol Van Dorpe,1,4 Uwe Himmelreich,2,3 Liesbet Lagae1,4 1Department of Life Science Technology, Imec, 2Department of Imaging and Pathology, Faculty of Medicine, Biomedical MRI Unit, 3Faculty of Medicine, Molecular Small Animal Imaging Center (MoSAIC, 4Department of Physics, Faculty of Sciences, Laboratory of Solid State Physics and Magnetism, KU Leuven, Leuven, Belgium Abstract: The need for sensitive imaging techniques to detect tumor cells is an important issue in cancer diagnosis and therapy. Surface-enhanced Raman scattering (SERS, realized by chemisorption of compounds suitable for Raman spectroscopy onto gold nanoparticles, is a new method for detecting a tumor. As a proof of concept, we studied the use of biocompatible gold nanostars as sensitive SERS contrast agents targeting an ovarian cancer cell line (SKOV3. Due to a high intracellular uptake of gold nanostars after 6 hours of exposure, they could be detected and located with SERS. Using these nanostars for passive targeting after systemic injection in a xenograft mouse model, a detectable signal was measured in the tumor and liver in vivo. These signals were confirmed by ex vivo SERS measurements and darkfield microscopy. In this study, we established SERS nanostars as a highly sensitive contrast agent for tumor detection, which opens the potential for their use as a theranostic agent against cancer. Keywords: SERS, gold nanostars, cancer imaging, Raman active

  7. Chemistry of paramagnetic and diamagnetic contrast agents for Magnetic Resonance Imaging and Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Mayoral, Elena [Laboratorio de Sintesis Organica e Imagen Molecular por Resonancia Magnetica, Facultad de Ciencias, UNED, Paseo Senda del Rey 9, E-28040 Madrid (Spain); Departamento de Quimica Inorganica y Quimica Tecnica, Facultad de Ciencias, UNED, Paseo Senda del Rey 9, E-28040 Madrid (Spain); Negri, Viviana; Soler-Padros, Jordi [Laboratorio de Sintesis Organica e Imagen Molecular por Resonancia Magnetica, Facultad de Ciencias, UNED, Paseo Senda del Rey 9, E-28040 Madrid (Spain); Cerdan, Sebastian [Laboratorio de Imagen Espectroscopica por Resonancia Magnetica (LIERM), Instituto de Investigaciones Biomedicas ' Alberto Sols' , CSIC/UAM, c/Arturo Duperier 4, E-28029 Madrid (Spain); Ballesteros, Paloma [Laboratorio de Sintesis Organica e Imagen Molecular por Resonancia Magnetica, Facultad de Ciencias, UNED, Paseo Senda del Rey 9, E-28040 Madrid (Spain)], E-mail: pballesteros@ccia.uned.es

    2008-09-15

    We provide a brief overview of the chemistry and most relevant properties of paramagnetic and diamagnetic contrast agents (CAs) for Magnetic Resonance Imaging and Magnetic Resonance Spectroscopic Imaging. Paramagnetic CAs for MRI consist mainly of Gd(III) complexes from linear or macrocyclic polyaminopolycarboxylates. These agents reduce, the relaxation times T{sub 1} and T{sub 2} of the water protons in a concentration dependent manner, increasing selectively MRI contrast in those regions in which they accumulate. In most instances they provide anatomical information on the localization of lesions and in some specific cases they may allow to estimate some physiological properties of tissues including mainly vascular performance. Because of its ability to discriminate easily between normal and diseased tissue, extracellular pH (pH{sub e}) has been added recently, to the battery of variables amenable to MRI investigation. A variety of Gd(III) containing macrocycles sensitive to pH, endogenous or exogenous polypeptides or even liposomes have been investigated for this purpose, using the pH dependence of their relaxivity or magnetization transfer rate constant (chemical exchange saturation transfer, CEST). Many environmental circumstances in addition to pH affect, however, relaxivity or magnetization transfer rate constants of these agents, making the results of pH measurements by MRI difficult to interpret. To overcome these limitations, our laboratory synthesized and developed a novel series of diamagnetic CAs for Magnetic Resonance Spectroscopic Imaging, a new family of monomeric and dimeric imidazolic derivatives able to provide unambiguous measurements of pH{sub e}, independent of water relaxivity, diffusion or exchange.

  8. Effects of iodinated contrast agent, xylocaine and gadolinium concentration on the signal emitted in magnetic resonance arthrography: a samples study

    Directory of Open Access Journals (Sweden)

    Yvana Lopes Pinheiro da Silva

    2015-04-01

    Full Text Available Objective: To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality. Materials and Methods: Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration. Results: As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions. Conclusion: Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography.

  9. Carbon dioxide as a venous contrast agent: Applications in interventional radiology=20

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Seong Tae; Lee, Jae Mun; Kim, Choon Yul; Shinn, Kyung Sub [The Catholic Univ. College of Medicine, Seoul (Korea, Republic of); Pfammatter, Thomas; Cho, Kyung Jae [Univ. of Michigan Hospitals, Ann Arbor (United States)

    1997-09-01

    To evaluate the safety and usefulness of carbon dioxide(CO{sub 2}) as a venous contrast agent for upper-arm placement of peripherally inserted central venous catheter (PICC), vena caval filter placement, and for visualization of the portal vein in transjugular intrahepatic portosystemic shunt(TIPS). About 20-30ml of CO{sub 2} was used as an alternative to iodinated contrast material for digital subtraction angiography (DSA) and fluoroscopy to guide upper-arm placement of PICC in 46 patients, for inferior venacavogram before filter placement in five, and for visualization of the portal vein during TIPS in two. Vital signs, peripheral arterial oxygen saturation, and renal function were checked during and after delivery of CO{sub 2}. All CO{sub 2} DSA for PICC placement clearly delineated patency or stenosis of the central veins. In 41 of 46 patients (89 %), PICC placement with CO{sub 2} guidance was successful. The mean number of venipunctures for PICC placement was 1.9, and the mean volume of CO{sub 2} injected for venipuncture was 35ml. In five patients, Titanium Greenfield filters were successfully implanted into the inferior vena cava following CO{sub 2} vena cavography. In two patients in whom hepatopetal portal flow was seen on indirect portography, the portal vein was visualized by CO{sub 2}-wedged hepatic venography. Injection of CO{sub 2} into the splenic vein following TIPS placement revealed shunt patency. Vital signs and oxygen saturation did not change, and there was no evidence of renal toxicity following CO{sub 2}injection. CO{sub 2} is a safe and useful alternative contrast agent for upper-arm placement of PICC, pre-filter placement cavography, and wedged hepatic venography and portography for TIPS.

  10. Carbon dioxide as a venous contrast agent: Applications in interventional radiology=20

    International Nuclear Information System (INIS)

    Hahn, Seong Tae; Lee, Jae Mun; Kim, Choon Yul; Shinn, Kyung Sub; Pfammatter, Thomas; Cho, Kyung Jae

    1997-01-01

    To evaluate the safety and usefulness of carbon dioxide(CO 2 ) as a venous contrast agent for upper-arm placement of peripherally inserted central venous catheter (PICC), vena caval filter placement, and for visualization of the portal vein in transjugular intrahepatic portosystemic shunt(TIPS). About 20-30ml of CO 2 was used as an alternative to iodinated contrast material for digital subtraction angiography (DSA) and fluoroscopy to guide upper-arm placement of PICC in 46 patients, for inferior venacavogram before filter placement in five, and for visualization of the portal vein during TIPS in two. Vital signs, peripheral arterial oxygen saturation, and renal function were checked during and after delivery of CO 2 . All CO 2 DSA for PICC placement clearly delineated patency or stenosis of the central veins. In 41 of 46 patients (89 %), PICC placement with CO 2 guidance was successful. The mean number of venipunctures for PICC placement was 1.9, and the mean volume of CO 2 injected for venipuncture was 35ml. In five patients, Titanium Greenfield filters were successfully implanted into the inferior vena cava following CO 2 vena cavography. In two patients in whom hepatopetal portal flow was seen on indirect portography, the portal vein was visualized by CO 2 -wedged hepatic venography. Injection of CO 2 into the splenic vein following TIPS placement revealed shunt patency. Vital signs and oxygen saturation did not change, and there was no evidence of renal toxicity following CO 2 injection. CO 2 is a safe and useful alternative contrast agent for upper-arm placement of PICC, pre-filter placement cavography, and wedged hepatic venography and portography for TIPS

  11. Tyrosinase-catalyzed melanin as a contrast agent for photoacoustic tomography

    Science.gov (United States)

    Krumholz, Arie; Chavez, Sarah; Yao, Junjie; Fleming, Timothy; Gillanders, William E.; Wang, Lihong V.

    2011-03-01

    It is difficult to distinguish between tumor cells and surrounding cells without staining as is done in histology. We developed tyrosinase-catalyzed melanin as a reporter gene for photoacoustic tomography. Tyrosinase is the primary enzyme responsible for the production of melanin and alone is sufficient to produce melanin in non-melanogenic cells. Two cell lines were created: a stably transfected HeLa line and a transiently transfected 293 line. A phantom experiment was performed with the 293 transfected cells 48 hours post transfection and the results compared with oxygenated whole blood, B16 melanoma and 293 control cells. An in vivo experiment was performed using the transfected HeLa cells xenografted into a nude mouse ear, and then imaged. The results show strong contrast for tyrosinase-catalyzed melanin in both the 293 cells in the tube phantom as well as the in vivo result showing melanin in a nude mouse ear. Transfection increased expression in 293 cells 159 fold and image contrast compared to blood by as much as 50 fold. Due to the strong signal obtained at longer wavelengths and the decrease of blood signal at the same wavelengths, tyrosinase catalyzed melanin is a good candidate as a molecular imaging contrast agent for photoacoustic tomography.

  12. Recent advances in ytterbium-based contrast agents for in vivo X-ray computed tomography imaging: promises and prospects.

    Science.gov (United States)

    Liu, Yanlan; Liu, Jianhua; Ai, Kelong; Yuan, Qinghai; Lu, Lehui

    2014-01-01

    X-ray computed tomography (CT) imaging is one of the most widely used diagnostic imaging techniques in the clinic, and has raised significant interest in recent years both in research and practice owing to its many advantages such as deep penetration depth, high resolution and facile image processing. Developing heavy metal-based CT contrast agents, especially heavy metal-containing nanoparticulate CT contrast agents, has become a key focus in research fields to address issues of clinical iodinated agents involving short circulation time, low contrast efficiency and potential renal toxicity. In this review, we summarize the development of ytterbium (Yb)-based CT contrast agents and highlight the design and applications of Yb-based nanoparticulate CT contrast agents. Yb has high atomic number and higher abundance in the earth's crust relative to Au, Ta and Bi, which have received much attention as a CT contrast agents. In particular, in contrast to these metal elements, as well as I, Yb has K-edge energy that is located just within the higher-intensity region of X-ray spectra, which can induce significant enhancement in the contrast efficiency. When encapsulated in nanoparticles, Yb can remain in the circulation for a long time. This long in vivo circulation time, combined with the proper K-edge energy and a large absorption cross-section of Yb in the near-infrared region, makes Yb-based nanoparticles particularly promising in angiography, 'multicolor' spectral CT imaging, and multimodal imaging. Finally, we also discuss the prospects and the challenges in the development of Yb-based CT contrast agents. Copyright © 2014 John Wiley & Sons, Ltd.

  13. Biofilm imaging in porous media by laboratory X-Ray tomography: Combining a non-destructive contrast agent with propagation-based phase-contrast imaging tools.

    Science.gov (United States)

    Carrel, Maxence; Beltran, Mario A; Morales, Verónica L; Derlon, Nicolas; Morgenroth, Eberhard; Kaufmann, Rolf; Holzner, Markus

    2017-01-01

    X-ray tomography is a powerful tool giving access to the morphology of biofilms, in 3D porous media, at the mesoscale. Due to the high water content of biofilms, the attenuation coefficient of biofilms and water are very close, hindering the distinction between biofilms and water without the use of contrast agents. Until now, the use of contrast agents such as barium sulfate, silver-coated micro-particles or 1-chloronaphtalene added to the liquid phase allowed imaging the biofilm 3D morphology. However, these contrast agents are not passive and potentially interact with the biofilm when injected into the sample. Here, we use a natural inorganic compound, namely iron sulfate, as a contrast agent progressively bounded in dilute or colloidal form into the EPS matrix during biofilm growth. By combining a very long source-to-detector distance on a X-ray laboratory source with a Lorentzian filter implemented prior to tomographic reconstruction, we substantially increase the contrast between the biofilm and the surrounding liquid, which allows revealing the 3D biofilm morphology. A comparison of this new method with the method proposed by Davit et al (Davit et al., 2011), which uses barium sulfate as a contrast agent to mark the liquid phase was performed. Quantitative evaluations between the methods revealed substantial differences for the volumetric fractions obtained from both methods. Namely, contrast agent-biofilm interactions (e.g. biofilm detachment) occurring during barium sulfate injection caused a reduction of the biofilm volumetric fraction of more than 50% and displacement of biofilm patches elsewhere in the column. Two key advantages of the newly proposed method are that passive addition of iron sulfate maintains the integrity of the biofilm prior to imaging, and that the biofilm itself is marked by the contrast agent, rather than the liquid phase as in other available methods. The iron sulfate method presented can be applied to understand biofilm development

  14. Biofilm imaging in porous media by laboratory X-Ray tomography: Combining a non-destructive contrast agent with propagation-based phase-contrast imaging tools.

    Directory of Open Access Journals (Sweden)

    Maxence Carrel

    Full Text Available X-ray tomography is a powerful tool giving access to the morphology of biofilms, in 3D porous media, at the mesoscale. Due to the high water content of biofilms, the attenuation coefficient of biofilms and water are very close, hindering the distinction between biofilms and water without the use of contrast agents. Until now, the use of contrast agents such as barium sulfate, silver-coated micro-particles or 1-chloronaphtalene added to the liquid phase allowed imaging the biofilm 3D morphology. However, these contrast agents are not passive and potentially interact with the biofilm when injected into the sample. Here, we use a natural inorganic compound, namely iron sulfate, as a contrast agent progressively bounded in dilute or colloidal form into the EPS matrix during biofilm growth. By combining a very long source-to-detector distance on a X-ray laboratory source with a Lorentzian filter implemented prior to tomographic reconstruction, we substantially increase the contrast between the biofilm and the surrounding liquid, which allows revealing the 3D biofilm morphology. A comparison of this new method with the method proposed by Davit et al (Davit et al., 2011, which uses barium sulfate as a contrast agent to mark the liquid phase was performed. Quantitative evaluations between the methods revealed substantial differences for the volumetric fractions obtained from both methods. Namely, contrast agent-biofilm interactions (e.g. biofilm detachment occurring during barium sulfate injection caused a reduction of the biofilm volumetric fraction of more than 50% and displacement of biofilm patches elsewhere in the column. Two key advantages of the newly proposed method are that passive addition of iron sulfate maintains the integrity of the biofilm prior to imaging, and that the biofilm itself is marked by the contrast agent, rather than the liquid phase as in other available methods. The iron sulfate method presented can be applied to understand

  15. Dynamic contrast-enhanced MRI using a macromolecular MR contrast agent (P792): Evaluation of antivascular drug effect in a rabbit VX2 liver tumor model

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Sun [Dept. of Radiology, Konkuk University School of Medicine, Seoul (Korea, Republic of); Han, Joon Koo; Lee, Jeong Min; Woo, Sung Min; Choi, Byung Ihn [Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Young Il [Dept. of Radiology, Sheikh Khalifa Specialty Hospital, Ras Al Khaimah (United Arab Emirates); Choi, Jin Young [Dept. of Radiology, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-10-15

    To evaluate the utility of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using macromolecular contrast agent (P792) for assessment of vascular disrupting drug effect in rabbit VX2 liver tumor models. This study was approved by our Institutional Animal Care and Use Committee. DCE-MRI was performed with 3-T scanner in 13 VX2 liver tumor-bearing rabbits, before, 4 hours after, and 24 hours after administration of vascular disrupting agent (VDA), using gadomelitol (P792, n = 7) or low molecular weight contrast agent (gadoterate meglumine [Gd-DOTA], n = 6). P792 was injected at a of dose 0.05 mmol/kg, while that of Gd-DOTA was 0.2 mmol/kg. DCE-MRI parameters including volume transfer coefficient (Ktrans) and initial area under the gadolinium concentration-time curve until 60 seconds (iAUC) of tumors were compared between the 2 groups at each time point. DCE-MRI parameters were correlated with tumor histopathology. Reproducibility in measurement of DCE-MRI parameters and image quality of source MR were compared between groups. P792 group showed a more prominent decrease in Ktrans and iAUC at 4 hours and 24 hours, as compared to the Gd-DOTA group. Changes in DCE-MRI parameters showed a weak correlation with histologic parameters (necrotic fraction and microvessel density) in both groups. Reproducibility of DCE-MRI parameters and overall image quality was not significantly better in the P792 group, as compared to the Gd-DOTA group. Dynamic contrast-enhanced magnetic resonance imaging using a macromolecular contrast agent shows changes of hepatic perfusion more clearly after administration of the VDA. Gadolinium was required at smaller doses than a low molecular contrast agent.

  16. Cranial nerve contrast using nerve-specific fluorophores improved by paired-agent imaging with indocyanine green as a control agent

    Science.gov (United States)

    Torres, Veronica C.; Vuong, Victoria D.; Wilson, Todd; Wewel, Joshua; Byrne, Richard W.; Tichauer, Kenneth M.

    2017-09-01

    Nerve preservation during surgery is critical because damage can result in significant morbidity. This remains a challenge especially for skull base surgeries where cranial nerves (CNs) are involved because visualization and access are particularly poor in that location. We present a paired-agent imaging method to enhance identification of CNs using nerve-specific fluorophores. Two myelin-targeting imaging agents were evaluated, Oxazine 4 and Rhodamine 800, and coadministered with a control agent, indocyanine green, either intravenously or topically in rats. Fluorescence imaging was performed on excised brains ex vivo, and nerve contrast was evaluated via paired-agent ratiometric data analysis. Although contrast was improved among all experimental groups using paired-agent imaging compared to conventional, solely targeted imaging, Oxazine 4 applied directly exhibited the greatest enhancement, with a minimum 3 times improvement in CNs delineation. This work highlights the importance of accounting for nonspecific signal of targeted agents, and demonstrates that paired-agent imaging is one method capable of doing so. Although staining, rinsing, and imaging protocols need to be optimized, these findings serve as a demonstration for the potential use of paired-agent imaging to improve contrast of CNs, and consequently, surgical outcome.

  17. Ultrasound contrast agent imaging: Real-time imaging of the superharmonics

    Energy Technology Data Exchange (ETDEWEB)

    Peruzzini, D.; Viti, J. [MSD lab, Department of Information Engineering, Univ of Florence, Via S.Marta, 3, 50139 Firenze (Italy); Erasmus MC, ’s-Gravendijkwal 230, Faculty Building, Ee 2302, 3015 CE Rotterdam (Netherlands); Tortoli, P. [MSD lab, Department of Information Engineering, Univ of Florence, Via S.Marta, 3, 50139 Firenze (Italy); Verweij, M. D. [Acoustical Wavefield Imaging, ImPhys, Delft Univ Technology, van der Waalsweg 8, 2628 CH Delft (Netherlands); Jong, N. de; Vos, H. J., E-mail: h.vos@erasmusmc.nl [Erasmus MC, ’s-Gravendijkwal 230, Faculty Building, Ee 2302, 3015 CE Rotterdam (Netherlands); Acoustical Wavefield Imaging, ImPhys, Delft Univ Technology, van der Waalsweg 8, 2628 CH Delft (Netherlands)

    2015-10-28

    Currently, in medical ultrasound contrast agent (UCA) imaging the second harmonic scattering of the microbubbles is regularly used. This scattering is in competition with the signal that is caused by nonlinear wave propagation in tissue. It was reported that UCA imaging based on the third or higher harmonics, i.e. “superharmonic” imaging, shows better contrast. However, the superharmonic scattering has a lower signal level compared to e.g. second harmonic signals. This study investigates the contrast-to-tissue ratio (CTR) and signal to noise ratio (SNR) of superharmonic UCA scattering in a tissue/vessel mimicking phantom using a real-time clinical scanner. Numerical simulations were performed to estimate the level of harmonics generated by the microbubbles. Data were acquired with a custom built dual-frequency cardiac phased array probe. Fundamental real-time images were produced while beam formed radiofrequency (RF) data was stored for further offline processing. The phantom consisted of a cavity filled with UCA surrounded by tissue mimicking material. The acoustic pressure in the cavity of the phantom was 110 kPa (MI = 0.11) ensuring non-destructivity of UCA. After processing of the acquired data from the phantom, the UCA-filled cavity could be clearly observed in the images, while tissue signals were suppressed at or below the noise floor. The measured CTR values were 36 dB, >38 dB, and >32 dB, for the second, third, and fourth harmonic respectively, which were in agreement with those reported earlier for preliminary contrast superharmonic imaging. The single frame SNR values (in which ‘signal’ denotes the signal level from the UCA area) were 23 dB, 18 dB, and 11 dB, respectively. This indicates that noise, and not the tissue signal, is the limiting factor for the UCA detection when using the superharmonics in nondestructive mode.

  18. Characteristics and Echogenicity of Clinical Ultrasound Contrast Agents: An In Vitro and In Vivo Comparison Study.

    Science.gov (United States)

    Hyvelin, Jean-Marc; Gaud, Emmanuel; Costa, Maria; Helbert, Alexandre; Bussat, Philippe; Bettinger, Thierry; Frinking, Peter

    2017-05-01

    To compare physicochemical characteristics and in vitro and in vivo contrast-enhanced ultrasound imaging performance of 3 commercially available ultrasound contrast agents: SonoVue (Bracco Imaging SpA, Colleretto Giacosa, Italy; also marketed as Lumason in the USA), Definity (Lantheus Medical Imaging, North Billerica, MA) and Optison (GE Healthcare AS, Oslo, Norway). Physicochemical characteristics were measured with a Multisizer Coulter Counter (Beckman Coulter, Fullerton, CA). Two ultrasound systems (Aplio 500; Toshiba Medical Systems Corp, Tochigi-ken, Japan; and Logiq E9; GE Healthcare, Little Chalfont, England) were used with different transducers. Contrast enhancement was measured in vitro by dose-ranging measurements using a custom-built beaker setup; in vivo imaging performances were compared in pigs (heart and liver) and rabbits (liver). Quantitative analyses were performed with VueBox quantification software (Bracco Suisse SA, Plan-les-Ouates, Switzerland). Measured physicochemical characteristics were in agreement with those provided by the manufacturers. In vitro data demonstrated that the performance of SonoVue was similar to or better than that of Definity but superior to Optison (normalized scattered power 2- to 10-fold higher with SonoVue). Similar results were obtained in vivo, although the duration of enhancement in the pig heart was longer for SonoVue compared to Definity, and quantitative analysis revealed higher enhancement for SonoVue (1.5-fold increase). For liver imaging, SonoVue and Definity showed similar contrast enhancement and duration of enhancement, but compared to Optison, both peak enhancement and duration of enhancement were superior for SonoVue (up to 2-fold increase). Imaging performance of SonoVue was similar to or slightly better than that of Definity, but it was superior to Optison for the conditions used in this study. © 2017 by the American Institute of Ultrasound in Medicine.

  19. The Sonochemical and Biological Effects of Three Clinically-Used Contrast Agents

    Science.gov (United States)

    Mariame A. Hassan,; Loreto B. Feril, Jr.,; Nobuki Kudo,; Katsuro Tachibana,; Takashi Kondo,; Peter Riesz,

    2010-07-01

    The encapsulation of gas bubbles has resulted in improved stability and added a binding capacity to shells for ultrasound-guided targeted delivery. However, this has also changed the physical and acoustical properties of the final formulation. In this study, we have evaluated three clinically-used contrast agents of different compositions, namely, Levovist, Sonazoid, and SonoVue, with respect to their sonochemical and biological effects at different concentrations. The results showed that both shell elasticity and reactivity played a role in modulating both effects influencing the extent of ultrasound-induced free-radical formation. Microbubbles with elastic shells were found to be more capable of inducing delayed symptoms of cell killing, whereas the combined use of chemically reactive robust shells and high-density gases, such as perfluorocarbons, could exert a protective effect on cells. These conclusions offer new perspectives on how microbubbles interact with biological systems and might be useful in tailoring novel microbubbles in the future.

  20. Fluorine-19 Mri Contrast Agents for Cell Tracking and Lung Imaging

    Directory of Open Access Journals (Sweden)

    Matthew S. Fox

    2015-01-01

    Full Text Available Fluorine-19 ( 19 F-based contrast agents for magnetic resonance imaging stand to revolutionize imaging-based research and clinical trials in several fields of medical intervention. First, their use in characterizing in vivo cell behavior may help bring cellular therapy closer to clinical acceptance. Second, their use in lung imaging provides novel noninvasive interrogation of the ventilated airspaces without the need for complicated, hard-to-distribute hardware. This article reviews the current state of 19 F-based cell tracking and lung imaging using magnetic resonance imaging and describes the link between the methods across these fields and how they may mutually benefit from solutions to mutual problems encountered when imaging 19 F-containing compounds, as well as hardware and software advancements.

  1. Increased antibiotic release and equivalent biomechanics of a spacer cement without hard radio contrast agents.

    Science.gov (United States)

    Bitsch, R G; Kretzer, J P; Vogt, S; Büchner, H; Thomsen, M N; Lehner, B

    2015-10-01

    We compared a novel calcium carbonate spacer cement (Copal® spacem) to well-established bone cements. Electron microscopic structure and elution properties of the antibiotics ofloxacin, vancomycin, clindamycin, and gentamicin were examined. A knee wear simulator model for articulating cement spacers was established. Mechanical tests for bending strength, flexural modulus, and compressive and fatigue strength were performed. The electron microscopic analysis showed a microporous structure of the spacer cement, and this promoted a significantly higher and longer antibiotic elution. All spacer cement specimens released the antibiotics for a period of up to 50days with the exception of the vancomycin loading. The spacer cement showed significantly less wear scars and fulfilled the ISO 5833 requirements. The newly developed spacer cement is a hydrophilic antibiotic carrier with an increased release. Cement without hard radio contrast agents can improve tribological behaviour of spacers, and this may reduce reactive wear particles and abrasive bone defects. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. In vivo photothermal optical coherence tomography of endogenous and exogenous contrast agents in the eye.

    Science.gov (United States)

    Lapierre-Landry, Maryse; Gordon, Andrew Y; Penn, John S; Skala, Melissa C

    2017-08-23

    Optical coherence tomography (OCT) has become a standard-of-care in retinal imaging. OCT allows non-invasive imaging of the tissue structure but lacks specificity to contrast agents that could be used for in vivo molecular imaging. Photothermal OCT (PT-OCT) is a functional OCT-based technique that has been developed to detect absorbers in a sample. We demonstrate in vivo PT-OCT in the eye for the first time on both endogenous (melanin) and exogenous (gold nanorods) absorbers. Pigmented mice and albino mice (n = 6 eyes) were used to isolate the photothermal signal from the melanin in the retina. Pigmented mice with laser-induced choroidal neovascularization lesions (n = 7 eyes) were also imaged after a systemic injection of gold nanorods to observe their passive accumulation in the retina. This experiment demonstrates the feasibility of PT-OCT to image the distribution of both endogenous and exogenous absorbers in the mouse retina.

  3. Voiding Urosonography with Second-Generation Ultrasound Contrast Agent for Diagnosis of Vesicoureteric Reflux: First Local Pilot Study

    Directory of Open Access Journals (Sweden)

    Dafina Kuzmanovska

    2017-04-01

    CONCLUSIONS: Contrast-enhanced voiding urosonography using intravesical second generation ultrasound contrast agent could be recommend  as a valid alternative diagnostic modality for detecting vesicoureteral reflux and evaluation of the distal urinary tract in children, based on its radiation-free, highly efficacious, reliable, and safe characteristics.

  4. Collagen based magnetic nanobiocomposite as MRI contrast agent and for targeted delivery in cancer therapy.

    Science.gov (United States)

    Mandal, A; Sekar, S; Kanagavel, M; Chandrasekaran, N; Mukherjee, A; Sastry, T P

    2013-10-01

    In this study, an attempt has been made with the advent of technology to prepare a multifunctional nanobiocomposite (NBC) for targeted drug delivery in cancer therapy. Collagen (C) was fabricated as nanofibers with multifunctional moieties viz. CFeAb*D by incorporating iron oxide nanoparticles (Fe), coupling with fluorescein isothiocyanate (FITC) labeled antibody (Ab*) and loading an anticancer gemcitabine drug (D). This NBC was characterized by conventional methods and evaluated for its biological activities. The UV-vis and FTIR spectroscopic studies revealed the fluorescein to protein ratio and revealed the presence of iron oxide nanoparticles and their interaction with the collagen molecules, respectively. While SDS-PAGE showed the proteinaceous nature of collagen, VSM and TEM studies revealed magnetic saturation as 54.97emu/g and a magnetic nanoparticle with a diameter in the range of 10-30nm and the dimension of nanofiber ranging from 97 to 270nm. A MRI scan has shown a super paramagnetic effect, which reveals that the prepared NBC can be used as a MRI contrast agent. The MTT assay has shown biocompatibility and an apoptotic effect while phase contrast microscopy exhibited receptor mediated uptake of endocytosis. The novelty in the prepared NBC lies in the collagen nanofibers, which have a higher penetrating property without causing much cell damage, biocompatibility and multifunctional properties and is able to carry multifunctional agents. The study has demonstrated the possible use of CFeAb*D as a multifunctional NBC for biomedical applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Sub-second proton imaging of 13C hyperpolarized contrast agents in water.

    Science.gov (United States)

    Truong, Milton L; Coffey, Aaron M; Shchepin, Roman V; Waddell, Kevin W; Chekmenev, Eduard Y

    2014-01-01

    Indirect proton detection of (13)C hyperpolarized contrast agents potentially enables greater sensitivity. Presented here is a study of sub-second projection imaging of hyperpolarized (13)C contrast agent addressing the obstacle posed by water suppression for indirect detection in vivo. Sodium acetate phantoms were used to develop and test water suppression and sub-second imaging with frequency-selective RF pulses using spectroscopic and imaging indirect proton detection. A 9.8 mm aqueous solution of (13)C PHIP hyperpolarized 2-hydroxyethyl-(13)C-propionate-d2,3,3 (HEP),  ~25% was used for demonstration of indirect proton sub-second imaging detection. Balanced 2D FSSFP (fast steady-state free precession) allowed the recording of proton images with a field of view of 64 × 64 mm(2) and spatial resolution 2 × 2 mm(2) with total acquisition time of less than 0.2 s. In thermally polarized sodium 1-(13)C-acetate, (13) C to (1)H polarization transfer efficiency of 45.1% of the theoretically predicted values was observed in imaging detection corresponding to an 11-fold overall sensitivity improvement compared with direct (13)C FSSFP imaging. (13)C to (1)H polarization transfer efficiency of 27% was observed in imaging detection, corresponding to a 3.25-fold sensitivity improvement compared with direct (13)C FSSFP imaging with hyperpolarized HEP. The range of potential applications and limitations of this sub-second and ultra-sensitive imaging approach are discussed. Copyright © 2014 John Wiley & Sons, Ltd.

  6. Synthesis and characterization of polyethylenimine-based iron oxide composites as novel contrast agents for MRI.

    Science.gov (United States)

    Masotti, A; Pitta, A; Ortaggi, G; Corti, M; Innocenti, C; Lascialfari, A; Marinone, M; Marzola, P; Daducci, A; Sbarbati, A; Micotti, E; Orsini, F; Poletti, G; Sangregorio, C

    2009-04-01

    Use of polyethylenimines (PEIs) of different molecular weight and selected carboxylated-PEI derivatives (PEI-COOH) in the synthesis and stabilization of iron oxide nanoparticles, to obtain possible multifunctional contrast agents. Oxidation of Fe(II) at slightly elevated pH and temperature resulted in the formation of highly soluble and stable nanocomposites of iron oxides and polymer. Composites were characterized and studied by atomic force microscopy (AFM), transmission electron microscopy (TEM), X-ray diffractometry, AC and DC magnetometry, NMR relaxometry and magnetic resonance imaging (MRI). From AFM the dimensions of the aggregates were found to be in the ~150-250 nm size region; the mean diameter of the magnetic core of the compounds named PEI-25, PEI-500 and PEI-COOH60 resulted d approximately 20 +/- 5 nm for PEI-25, d approximately 9.5 +/- 1.0 nm for PEI-500 and d approximately 6.8 +/- 1.0 nm for PEI-COOH60. In PEI-COOH60 TEM and X-ray diffractometry revealed small assemblies of mineral magnetic cores with clear indications that the main constituents are maghemite and/or magnetite as confirmed by AC and DC SQUID magnetometry. For PEI-COOH60, the study of NMR-dispersion profiles revealed r (1) and r (2) relaxivities comparable to superparamagnetic iron-oxide commercial compounds in the whole investigated frequency range 7 < or = nu < or = 212 MHz. PEI-25 was studied as possible MRI contrast agent (CA) to map the cerebral blood volume (CBV) and cerebral blood flow (CBF) in an animal model obtaining promising results. The reported compounds may be further functionalized to afford novel multifunctional systems for biomedical applications.

  7. Quantitative functional lung imaging with synchrotron radiation using inhaled xenon as contrast agent.

    Science.gov (United States)

    Bayat, S; Le Duc, G; Porra, L; Berruyer, G; Nemoz, C; Monfraix, S; Fiedler, S; Thomlinson, W; Suortti, P; Standertskjöld-Nordenstam, C G; Sovijärvi, A R

    2001-12-01

    Small airways play a key role in the distribution of ventilation and in the matching of ventilation to perfusion. The purpose of this study was to introduce an imaging method that allows measurement of regional lung ventilation and evaluation of the function of airways with a small diameter. The experiments were performed at the Medical Beamline of the European Synchrotron Radiation Facility. Monochromatic synchrotron radiation beams were used to obtain quantitative respiration-gated images of lungs and airways in two anaesthetized and mechanically ventilated rabbits using inhaled stable xenon (Xe) gas as a contrast agent. Two simultaneous images were acquired at two different energies, above and below the K-edge of Xe. Logarithmic subtraction of the two images yields absolute Xe concentrations. This technique is known as K-edge subtraction (KES) radiography. Two-dimensional planar and CT images were obtained showing spatial distribution of Xe concentrations within the airspaces, as well as the dynamics of filling with Xe. Bronchi down to 1 mm in diameter were visible both in the subtraction radiographs and in tomographic images. Absolute concentrations of Xe gas were calculated within the tube carrying the inhaled gas mixture, small and large bronchi, and lung tissue. Local time constants of ventilation with Xe were obtained by following the evolution of gas concentration in sequential computed tomography images. The results of this first animal study indicate that KES imaging of lungs with Xe gas as a contrast agent has great potential in studies of the distribution of ventilation within the lungs and of airway function, including airways with a small diameter.

  8. Theranostic liposomes as a bimodal carrier for magnetic resonance imaging contrast agent and photosensitizer.

    Science.gov (United States)

    Skupin-Mrugalska, Paulina; Sobotta, Lukasz; Warowicka, Alicja; Wereszczynska, Beata; Zalewski, Tomasz; Gierlich, Piotr; Jarek, Marcin; Nowaczyk, Grzegorz; Kempka, Marek; Gapinski, Jacek; Jurga, Stefan; Mielcarek, Jadwiga

    2018-03-01

    The present study is focused on the development of liposomes bearing gadolinium chelate (GdLip) providing two functionalities for magnetic resonance imaging (MRI) and photodynamic therapy of cancer. A lipid derivative of gadolinium(III) diethylenetriamine pentaacetic acid salt (GdDTPA1) was inserted in the liposomal membrane and served as MRI contrast agent whereas a zinc phthalocyanine (ZnPc) was used as a model photosensitizer. In addition to conventional liposomes, pegylated lipids were used for the preparation of "stealth" liposomes. The characterization of different GdLip formulations involved evaluation of the liposomes size by nanoparticle tracking analysis, thermal phase behavior by differential scanning calorimetry and ZnPc-mediated singlet oxygen production. Furthermore, relaxivity measurements were performed as well as cytotoxicity and photodynamic activity against cancerous and normal cell lines was studied. Size and thermal behavior were only slightly influenced by GdLip composition, however it distinctly affected singlet oxygen production of ZnPc-loaded GdLip. The quantum yields of singlet oxygen generation by zinc phthalocyanine incorporated in GdLip containing cationic or/and pegylated lipids were smaller than those obtained for non-pegylated carriers with l-α-phosphatidylglycerol. In general, all formulations of GdLip, irrespectively of composition, were characterized by relaxivities higher than those of commercially used contrast agents (e.g. Magnevist®). NMR study has shown that the incorporation of ZnPc into the formulations of GdLip increases the relaxation parameters r 1 and r 2 , compared to the values for the non-loaded vesicles. GdDTPA1 did not influence the photodynamic activity of ZnPc against HeLa cells. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Physicochemical characterization of a novel graphene-based magnetic resonance imaging contrast agent

    Directory of Open Access Journals (Sweden)

    Kanakia S

    2013-08-01

    Full Text Available Shruti Kanakia,1 Jimmy D Toussaint,1 Sayan Mullick Chowdhury,1 Gaurav Lalwanim,1 Tanuf Tembulkar,1 Terry Button,1,2 Kenneth R Shroyer,3 William Moore,2 Balaji Sitharaman11Department of Biomedical Engineering, 2Department of Radiology, 3Department of Pathology, Stony Brook University, Stony Brook, NY, USAAbstract: We report the synthesis and characterization of a novel carbon nanostructure-based magnetic resonance imaging contrast agent (MRI CA; graphene nanoplatelets intercalated with manganese (Mn2+ ions, functionalized with dextran (GNP-Dex; and the in vitro assessment of its essential preclinical physicochemical properties: osmolality, viscosity, partition coefficient, protein binding, thermostability, histamine release, and relaxivity. The results indicate that, at concentrations between 0.1 and 100.0 mg/mL, the GNP-Dex formulations are hydrophilic, highly soluble, and stable in deionized water, as well as iso-osmolar (upon addition of mannitol and iso-viscous to blood. At potential steady-state equilibrium concentrations in blood (0.1–10.0 mg/mL, the thermostability, protein-binding, and histamine-release studies indicate that the GNP-Dex formulations are thermally stable (with no Mn2+ ion dissociation, do not allow non-specific protein adsorption, and elicit negligible allergic response. The r1 relaxivity of GNP-Dex was 92 mM-1s-1 (per-Mn2+ ion, 22 MHz proton Larmor frequency; ~20- to 30-fold greater than that of clinical gadolinium (Gd3+- and Mn2+-based MRI CAs. The results open avenues for preclinical in vivo safety and efficacy studies with GNP-Dex toward its development as a clinical MRI CA.Keywords: manganese, dextran, preclinical, physicochemical properties, relaxivity, graphene, magnetic resonance imaging, contrast agent

  10. Oral gadopentetate dimeglumine administration as a negative gastrointestinal contrast agent to improve image quality of MR cholangiopancreatography

    International Nuclear Information System (INIS)

    Chen Yi; Xu Yikai; Zhao Yuhui; Wang Guisheng

    2008-01-01

    Objective: To choose optimal concentration and volume of Gd-DTPA solution as a oral gastrointestinal negative contrast agent for MRCP. To evaluate the role of Gd-DTPA solution in improving image quality of MRCP. Methods: In vitro experiment: Gd-DTPA solution was made with different concentrations. T 1 WI, T 2 WI, two-dimensional single slice fast spin echo sequence and three-dimensional half-fourier acquisition single-shot fast spin echo sequence were performed to measure the signal intensity of these contrast agents respectively, so Gd-DTPA solution with the optimal concentration can be decided as oral negative gastrointestinal contrast agent on MRCP. Clinical study: The Gd-DTPA solution with optimal concentration and volume was regarded as an oral negative gastrointestinal contrast agent of MRCP. Twenty- four' patients were performed with MRCP before and after (5-10 minutes and 10-15 minutes) administration of oral negative gastrointestinal contrast agent and image quality was analyzed. Statistical analysis was performed using analysis of variance with SPSS 10.0. Results: When the concentration of Gd-DTPA solution was ≤0.01 mol/L, the contrast agent was hyperintense on T 1 WI. On T 2 WI, when the concentration was ≥0.015 mol/L, it was as hypointense as basic ground; On 2D FSE MRCP images, controls were hyperintense and the contrast agent with concentration ranging from 0.0025 mol/L to 0.03 mol/L was hypointense. On 3D HEAST MRCP image, controls were hyperintense and when the concentration of Gd-DTPA was ≥0.01 mol, the contrast agent was hypointense. The Gd-DTPA solution with the concentration of 0.01 mol/L and the volume of 100 ml was chosen as MRCP oral negative gastrointestinal contrast agent. On MRCP images after oral administration of the contrast agent, in 10-15 minutes, the average grade scores within 24 patients of the intrahepatic bile duct, the common hepatic bile duct, the gall bladder, the common bile duct and pancreatic duct (the average grade

  11. Use of contrast-enhanced ultrasonography with a perflubutane-based contrast agent performed one day after transarterial chemoembolization for the early assessment of residual viable hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Takizawa, Kenichi; Numata, Kazushi; Morimoto, Manabu; Kondo, Masaaki; Nozaki, Akito; Moriya, Satoshi; Ishii, Tomohiro; Oshima, Takashi; Fukuda, Hiroyuki; Okada, Masahiro; Takebayashi, Shigeo; Maeda, Shin; Tanaka, Katsuaki

    2013-01-01

    Objective: We evaluated the efficacy of contrast-enhanced ultrasonography (US), compared with contrast-enhanced computed tomography (CT), for early assessments after transarterial chemoembolization (TACE) for the treatment of hypervascular hepatocellular carcinoma (HCC) lesions. Subjects and methods: Thirty-two patients with 59 HCC lesions who were scheduled to receive TACE were enrolled in this prospective study. TACE was performed by injecting a mixture of iodized oil and miriplatin hydrate, followed by a gelatin sponge. Digital subtraction angiography (DSA) and/or contrast-enhanced CT were performed 2–6 months after TACE and were used as the reference standard for residual HCC; the detection rates for residual viable HCC using contrast-enhanced US with a perflubutane-based contrast agent and a high mechanical index (MI) mode performed one day after TACE were also compared with those obtained using contrast-enhanced CT performed one month after TACE. The comparisons were made using the McNemar test. Results: Forty-seven (79.7%) of the 59 HCC lesions were diagnosed as having residual viability based on DSA and contrast-enhanced CT findings obtained 2–6 months after TACE. Eight (17.0%) of the 47 HCC lesions that were diagnosed as having residual viability using one-day contrast-enhanced US were not detected using one-month contrast-enhanced CT because of artifacts produced by the high attenuation of the iodized oil. The detection rate for residual HCC lesions using one-day contrast-enhanced US (95.7%, 45/47) was significantly higher than that using one-month contrast-enhanced CT (78.7%, 37/47) (P < 0.05). Conclusion: Contrast-enhanced US performed one day after TACE is more sensitive than contrast-enhanced CT performed one month after TACE for detecting residual viable HCC

  12. A Feasibility Study for Microwave Breast Cancer Detection Using Contrast-Agent-Loaded Bacterial Microbots

    Directory of Open Access Journals (Sweden)

    Yifan Chen

    2013-01-01

    Full Text Available We propose a new approach to microwave breast tumor sensing and diagnosis based on the use of biocompatible flagellated magnetotactic bacteria (MTB adapted to operate in human microvasculature. It has been verified experimentally by Martel et al. that externally generated magnetic gradients could be applied to guide the MTB along preplanned routes inside the human body, and a nanoload could be attached to these bacterial microbots. Motivated by these useful properties, we suggest loading a nanoscale microwave contrast agent such as carbon nanotubes (CNTs or ferroelectric nanoparticles (FNPs onto the MTB in order to modify the dielectric properties of tissues near the agent-loaded bacteria. Subsequently, we propose a novel differential microwave imaging (DMI technique to track simultaneously multiple swarms of MTB microbots injected into the breast. We also present innovative strategies to detect and localize a breast tissue malignancy and estimate its size via this DMI-trackable bacterial microrobotic system. Finally, we use an anatomically realistic numerical breast phantom as a platform to demonstrate the feasibility of this tumor diagnostic method.

  13. Voiding urosonography with ultrasound contrast agents for the diagnosis of vesicoureteric reflux in children

    Science.gov (United States)

    2007-01-01

    Voiding urosonography (VUS) encompasses examination of the urinary tract with intravesical administration of US contrast agent (UCA) for diagnosis of vesicoureteric reflux (VUR). The real breakthrough for US examination of VUR came with the availability of stabilized UCAs in the mid-1990s. This article presents a comprehensive review of various procedural aspects of VUS. Different US modalities are available for detecting the echogenic microbubbles: fundamental mode, colour Doppler US, harmonic imaging and dedicated contrast imaging with multiple display options. The reflux is graded (1 to 5) in a similar manner to the system used in voiding cystourethrography (VCUG). The most commonly used UCA for VUS, Levovist, is galactose-based and contains air-filled microbubbles. The recommended concentration is 300 mg/ml at a dose of 5–10%, or less than 5%, of the bladder filling volume when using fundamental or harmonic imaging modes, respectively. There are preliminary reports of VUS using a second-generation UCA, SonoVue. Here the UCA volume is less than 1% of the bladder filling volume. There is no specific contraindication to intravesical administration of UCA. The safety profile of intravesical Levovist is very high with no reports of side effects over a decade of use in VUS. PMID:17618429

  14. In situ gold nanoparticles formation: contrast agent for dental optical coherence tomography.

    Science.gov (United States)

    Braz, Ana K S; de Araujo, Renato E; Ohulchanskyy, Tymish Y; Shukla, Shoba; Bergey, Earl J; Gomes, Anderson S L; Prasad, Paras N

    2012-06-01

    In this work we demonstrate the potential use of gold nanoparticles as contrast agents for the optical coherence tomography (OCT) imaging technique in dentistry. Here, a new in situ photothermal reduction procedure was developed, producing spherical gold nanoparticles inside dentinal layers and tubules. Gold ions were dispersed in the primer of commercially available dental bonding systems. After the application and permeation in dentin by the modified adhesive systems, the dental bonding materials were photopolymerized concurrently with the formation of gold nanoparticles. The gold nanoparticles were visualized by scanning electron microscopy (SEM). The SEM images show the presence of gold nanospheres in the hybrid layer and dentinal tubules. The diameter of the gold nanoparticles was determined to be in the range of 40 to 120 nm. Optical coherence tomography images were obtained in two- and three-dimensions. The distribution of nanoparticles was analyzed and the extended depth of nanosphere production was determined. The results show that the OCT technique, using in situ formed gold nanoparticles as contrast enhancers, can be used to visualize dentin structures in a non-invasive and non-destructive way.

  15. Thrombin-Activatable Microbubbles as Potential Ultrasound Contrast Agents for the Detection of Acute Thrombosis.

    Science.gov (United States)

    Lux, Jacques; Vezeridis, Alexander M; Hoyt, Kenneth; Adams, Stephen R; Armstrong, Amanda M; Sirsi, Shashank R; Mattrey, Robert F

    2017-11-01

    Acute deep vein thrombosis (DVT) is the formation of a blood clot in the deep veins of the body that can lead to fatal pulmonary embolism. Acute DVT is difficult to distinguish from chronic DVT by ultrasound (US), the imaging modality of choice, and is therefore treated aggressively with anticoagulants, which can lead to internal bleeding. Here we demonstrate that conjugating perfluorobutane-filled (PFB-filled) microbubbles (MBs) with thrombin-sensitive activatable cell-penetrating peptides (ACPPs) could lead to the development of contrast agents that detect acute thrombosis with US imaging. Successful conjugation of ACPP to PFB-filled MBs was confirmed by fluorescence microscopy and flow cytometry. Fluorescein-labeled ACPP was used to evaluate the efficiency of thrombin-triggered cleavage by measuring the mean fluorescence intensity of ACPP-labeled MBs (ACPP-MBs) before and after incubation at 37 °C with thrombin. Lastly, control MBs and ACPP-MBs were infused through a tube containing a clot, and US contrast enhancement was measured with or without the presence of a thrombin inhibitor after washing the clot with saline. With thrombin activity, 91.7 ± 14.2% of the signal was retained after ACPP-MB infusion and washing, whereas only 16.7 ± 4% of the signal was retained when infusing ACPP-MBs in the presence of hirudin, a potent thrombin inhibitor.

  16. A Novel Polyacrylamide Magnetic Nanoparticle Contrast Agent for Molecular Imaging using MRI

    Directory of Open Access Journals (Sweden)

    Bradford A. Moffat

    2003-10-01

    Full Text Available A novel Polyacrylamide superparamagnetic iron oxide nanoparticle platform is described which has been synthetically prepared such that multiple crystals of iron oxide are encapsulated within a single Polyacrylamide matrix (PolyAcrylamide Magnetic [PAM] nanoparticles. This formulation provides for an extremely large T2 and T2* relaxivity of between 620 and 1140 sec−1 mM−1. Administration of PAM nanoparticles into rats bearing orthotopic 9L gliomas allowed quantitative pharmacokinetic analysis of the uptake of nanoparticles in the vasculature, brain, and glioma. Addition of polyethylene glycol of varying sizes (0.6, 2, and 10 kDa to the surface of the PAM nanoparticles resulted in an increase in plasma half-life and affected tumor uptake and retention of the nanoparticles as quantified by changes in tissue contrast using MRI. The flexible formulation of these nanoparticles suggests that future modifications could be accomplished allowing for their use as a targeted molecular imaging contrast agent and/or therapeutic platform for multiple indications.

  17. Hydrogel based tissue mimicking phantom for in-vitro ultrasound contrast agents studies.

    Science.gov (United States)

    Demitri, Christian; Sannino, Alessandro; Conversano, Francesco; Casciaro, Sergio; Distante, Alessandro; Maffezzoli, Alfonso

    2008-11-01

    Ultrasound medical imaging (UMI) is the most widely used image analysis technique, and often requires advanced in-vitro set up to perform morphological and functional investigations. These studies are based on contrast properties both related to tissue structure and injectable contrast agents (CA). In this work, we present a three-dimensional structure composed of two different hydrogels reassembly the microvascular network of a human tissue. This phantom was particularly suitable for the echocontrastographic measurements in human microvascular system. This phantom has been characterized to present the acoustic properties of an animal liver, that is, acoustic impedance (Z) and attenuation coefficient (AC), in UMI signal analysis in particular; the two different hydrogels have been selected to simulate the target organ and the acoustic properties of the vascular system. The two hydrogels were prepared starting from cellulose derivatives to simulating the target organ parenchyma and using a PEG-diacrylate to reproduce the vascular system. Moreover, harmonic analysis was performed on the hydrogel mimicking the liver parenchyma hydrogel to evaluate the ultrasound (US) distortion during echographic measurement. The phantom was employed in the characterization of an experimental US CA. Perfect agreement was found when comparing the hydrogel acoustical properties materials with the corresponding living reference tissues (i.e., vascular and parenchimal tissue).

  18. Applying tattoo dye as a third-harmonic generation contrast agent for in vivo optical virtual biopsy of human skin

    Science.gov (United States)

    Tsai, Ming-Rung; Lin, Chen-Yu; Liao, Yi-Hua; Sun, Chi-Kuang

    2013-02-01

    Third-harmonic generation (THG) microscopy has been reported to provide intrinsic contrast in elastic fibers, cytoplasmic membrane, nucleus, actin filaments, lipid bodies, hemoglobin, and melanin in human skin. For advanced molecular imaging, exogenous contrast agents are developed for a higher structural or molecular specificity. We demonstrate the potential of the commonly adopted tattoo dye as a THG contrast agent for in vivo optical biopsy of human skin. Spectroscopy and microscopy experiments were performed on cultured cells with tattoo dyes, in tattooed mouse skin, and in tattooed human skin to demonstrate the THG enhancement effect. Compared with other absorbing dyes or nanoparticles used as exogenous THG contrast agents, tattoo dyes are widely adopted in human skin so that future clinical biocompatibility evaluation is relatively achievable. Combined with the demonstrated THG enhancement effect, tattoo dyes show their promise for future clinical imaging applications.

  19. Quantitative Molecular Imaging with a Single Gd-Based Contrast Agent Reveals Specific Tumor Binding and Retention in Vivo.

    Science.gov (United States)

    Johansen, Mette L; Gao, Ying; Hutnick, Melanie A; Craig, Sonya E L; Pokorski, Jonathan K; Flask, Chris A; Brady-Kalnay, Susann M

    2017-06-06

    Magnetic resonance imaging (MRI) has become an indispensable tool in the diagnosis and treatment of many diseases, especially cancer. However, the poor sensitivity of MRI relative to other imaging modalities, such as PET, has hindered the development and clinical use of molecular MRI contrast agents that could provide vital diagnostic information by specifically locating a molecular target altered in the disease process. This work describes the specific and sustained in vivo binding and retention of a protein tyrosine phosphatase mu (PTPμ)-targeted, molecular magnetic resonance (MR) contrast agent with a single gadolinium (Gd) chelate using a quantitative MRI T 1 mapping technique in glioma xenografts. Quantitative T 1 mapping is an imaging method used to measure the longitudinal relaxation time, the T 1 relaxation time, of protons in a magnetic field after excitation by a radiofrequency pulse. T 1 relaxation times can in turn be used to calculate the concentration of a gadolinium-containing contrast agent in a region of interest, thereby allowing the retention or clearance of an agent to be quantified. In this context, retention is a measure of molecular contrast agent binding. Using conventional peptide chemistry, a PTPμ-targeted peptide was linked to a chelator that had been conjugated to a lysine residue. Following complexation with Gd, this PTPμ-targeted molecular contrast agent containing a single Gd ion showed significant tumor enhancement and a sustained increase in Gd concentration in both heterotopic and orthotopic tumors using dynamic quantitative MRI. This single Gd-containing PTPμ agent was more effective than our previous version with three Gd ions. Differences between nonspecific and specific agents, due to specific tumor binding, can be determined within the first 30 min after agent administration by examining clearance rates. This more facile chemistry, when combined with quantitative MR techniques, allows for widespread adoption by academic

  20. Arterial double-contrast dual-energy MDCT: in-vivo rabbit atherosclerosis with iodinated nanoparticles and gadolinium agents

    Science.gov (United States)

    Carmi, Raz; Kafri, Galit; Altman, Ami; Goshen, Liran; Planer, David; Sosna, Jacob

    2010-03-01

    An in-vivo feasibility study of potentially improved atherosclerosis CT imaging is presented. By administration of two different contrast agents to rabbits with induced atherosclerotic plaques we aim at identifying both soft plaque and vessel lumen simultaneously. Initial injection of iodinated nanoparticle (INP) contrast agent (N1177 - Nanoscan Imaging), two to four hours before scan, leads to its later accumulation in macrophage-rich soft plaque, while a second gadolinium contrast agent (Magnevist) injected immediately prior to the scan blends with the aortic blood. The distinction between the two agents in a single scan is achieved with a double-layer dual-energy MDCT (Philips Healthcare) following material separation analysis using the reconstructed images of the different x-ray spectra. A single contrast agent injection scan, where only INP was injected two hours prior to the scan, was compared to a double-contrast scan taken four hours after INP injection and immediately after gadolinium injection. On the single contrast agent scan we observed along the aorta walls, localized iodine accumulation which can point on INP uptake by atherosclerotic plaque. In the double-contrast scan the gadolinium contributes a clearer depiction of the vessel lumen in addition to the lasting INP presence. The material separation shows a good correlation to the pathologies inferred from the conventional CT images of the two different scans while performing only a single scan prevents miss-registration problems and reduces radiation dose. These results suggest that a double-contrast dual-energy CT may be used for advanced clinical diagnostic applications.

  1. Interaction of a high-order Bessel beam with a submerged spherical ultrasound contrast agent shell - Scattering theory.

    Science.gov (United States)

    Mitri, F G

    2010-03-01

    Acoustic scattering properties of ultrasound contrast agents are useful in extending existing or developing new techniques for biomedical imaging applications. A useful first step in this direction is to investigate the acoustic scattering of a new class of acoustic beams, known as helicoidal high-order Bessel beams, to improve the understanding of their scattering characteristics by an ultrasound contrast agent, which at present is very limited. The transverse acoustic scattering of a commercially available albuminoidal ultrasound contrast agent shell filled with air or a denser gas such as perfluoropropane and placed in a helicoidal Bessel beam of any order is examined numerically. The shell is assumed to possess an outer radius a=3.5 microns and a thickness of approximately 105 nm. Moduli of the total and resonance transverse acoustic scattering form functions are numerically evaluated in the bandwidth 0scattering of a helicoidal Bessel beam of order m1 so that the dynamics of contrast agents would be significantly altered. The main finding of the present theory is the suppression or enhancement for a particular resonance that may be used to advantage in imaging with ultrasound contrast agents for clinical applications. 2009 Elsevier B.V. All rights reserved.

  2. Assessing the efficacy of nano- and micro-sized magnetic particles as contrast agents for MRI cell tracking.

    Directory of Open Access Journals (Sweden)

    Arthur Taylor

    Full Text Available Iron-oxide based contrast agents play an important role in magnetic resonance imaging (MRI of labelled cells in vivo. Currently, a wide range of such contrast agents is available with sizes varying from several nanometers up to a few micrometers and consisting of single or multiple magnetic cores. Here, we evaluate the effectiveness of these different particles for labelling and imaging stem cells, using a mouse mesenchymal stem cell line to investigate intracellular uptake, retention and processing of nano- and microsized contrast agents. The effect of intracellular confinement on transverse relaxivity was measured by MRI at 7 T and in compliance with the principles of the '3Rs', the suitability of the contrast agents for MR-based cell tracking in vivo was tested using a chick embryo model. We show that for all particles tested, relaxivity was markedly reduced following cellular internalisation, indicating that contrast agent relaxivity in colloidal suspension does not accurately predict performance in MR-based cell tracking studies. Using a bimodal imaging approach comprising fluorescence and MRI, we demonstrate that labelled MSC remain viable following in vivo transplantation and can be tracked effectively using MRI. Importantly, our data suggest that larger particles might confer advantages for longer-term imaging.

  3. MR angiography of collateral arteries in a hind limb ischemia model: comparison between blood pool agent Gadomer and small contrast agent Gd-DTPA.

    Directory of Open Access Journals (Sweden)

    Karolien Jaspers

    Full Text Available The objective of this study was to compare the blood pool agent Gadomer with a small contrast agent for the visualization of ultra-small, collateral arteries (diameter0.10. Inter-observer variation was 24% and 18% for Gadomer and Gd-DTPA, respectively. In conclusion, blood pool agent Gadomer improved vessel conspicuity compared to Gd-DTPA. Steady-state MRA can be considered as an excellent non-invasive alternative to intra-arterial XRA for the visualization of ultra-small collateral arteries.

  4. Incorporation of paramagnetic, fluorescent and PET/SPECT contrast agents into liposomes for multimodal imaging

    Science.gov (United States)

    Mitchell, Nick; Kalber, Tammy L.; Cooper, Margaret S.; Sunassee, Kavitha; Chalker, Samantha L.; Shaw, Karen P.; Ordidge, Katherine L.; Badar, Adam; Janes, Samuel M.; Blower, Philip J.; Lythgoe, Mark F.; Hailes, Helen C.; Tabor, Alethea B.

    2013-01-01

    A series of metal-chelating lipid conjugates has been designed and synthesized. Each member of the series bears a 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) macrocycle attached to the lipid head group, using short n-ethylene glycol (n-EG) spacers of varying length. Liposomes incorporating these lipids, chelated to Gd3+, 64Cu2+, or 111In3+, and also incorporating fluorescent lipids, have been prepared, and their application in optical, magnetic resonance (MR) and single-photon emission tomography (SPECT) imaging of cellular uptake and distribution investigated in vitro and in vivo. We have shown that these multimodal liposomes can be used as functional MR contrast agents as well as radionuclide tracers for SPECT, and that they can be optimized for each application. When shielded liposomes were formulated incorporating 50% of a lipid with a short n-EG spacer, to give nanoparticles with a shallow but even coverage of n-EG, they showed good cellular internalization in a range of tumour cells, compared to the limited cellular uptake of conventional shielded liposomes formulated with 7% 1,2-distearoyl-sn-glycero-3-phosphoethanolamine-N-[carboxy(polyethyleneglycol)2000] (DSPE-PEG2000). Moreover, by matching the depth of n-EG coverage to the length of the n-EG spacers of the DOTA lipids, we have shown that similar distributions and blood half lives to DSPE-PEG2000-stabilized liposomes can be achieved. The ability to tune the imaging properties and distribution of these liposomes allows for the future development of a flexible tri-modal imaging agent. PMID:23131536

  5. Nerve-Highlighting Fluorescent Contrast Agents for Image-Guided Surgery

    Directory of Open Access Journals (Sweden)

    Summer L. Gibbs-Strauss

    2011-03-01

    Full Text Available Nerve damage is the major morbidity of many surgeries, resulting in chronic pain, loss of function, or both. The sparing of nerves during surgical procedures is a vexing problem because surrounding tissue often obscures them. To date, systemically administered nerve-highlighting contrast agents that can be used for nerve-sparing image-guided surgery have not been reported. In the current study, physicochemical and optical properties of 4,4‘-[(2-methoxy-1,4-phenylenedi-(1E-2,1-ethenediyl]bis-benzenamine (BMB and a newly synthesized, red-shifted derivative 4-[(1E-2-[4-[(1E-2-[4-aminophenyl]ethenyl]-3-methoxyphenyl]ethenyl]-benzonitrile (GE3082 were characterized in vitro and in vivo. Both agents crossed the blood-nerve barrier and blood-brain barrier and rendered myelinated nerves fluorescent after a single systemic injection. Although both BMB and GE3082 also exhibited significant uptake in white adipose tissue, GE3082 underwent a hypsochromic shift in adipose tissue that provided a means to eliminate the unwanted signal using hyperspectral deconvolution. Dose and kinetic studies were performed in mice to determine the optimal dose and drug-imaging interval. The results were confirmed in rat and pig, with the latter used to demonstrate, for the first time, simultaneous fluorescence imaging of blood vessels and nerves during surgery using the FLARE™ (Fluorescence-Assisted Resection and Exploration imaging system. These results lay the foundation for the development of ideal nerve-highlighting fluorophores for image-guided surgery.

  6. Cerenkov-specific contrast agents for detection of pH in vivo.

    Science.gov (United States)

    Czupryna, Julie; Kachur, Alexander V; Blankemeyer, Eric; Popov, Anatoliy V; Arroyo, Alejandro D; Karp, Joel S; Delikatny, Edward J

    2015-03-01

    We report the design, testing, and in vivo application of pH-sensitive contrast agents designed specifically for Cerenkov imaging. Radioisotopes used for PET emit photons via Cerenkov radiation. The multispectral emission of Cerenkov radiation allows for selective bandwidth quenching, in which a band of photons is quenched by absorption by a functional dye. Under acidic conditions, (18)F-labeled derivatives emit the full spectrum of Cerenkov light. Under basic conditions, the dyes change color and a wavelength-dependent quenching of Cerenkov emission is observed. Mono- and di-(18)F-labeled derivatives of phenolsulfonphthalein (phenol red) and meta-cresolsulfonphthalein (cresol purple) were synthesized by electrophilic fluorination. Cerenkov emission was measured at different wavelengths as a function of pH in vitro. Intramolecular response was measured in fluorinated probes and intermolecular quenching by mixing phenolphthalein with (18)F-FDG. Monofluorocresol purple (MFCP) was tested in mice treated with acetazolamide to cause urinary alkalinization, and Cerenkov images were compared with PET images. Fluorinated pH indicators were produced with radiochemical yields of 4%-11% at greater than 90% purity. Selective Cerenkov quenching was observed intramolecularly with difluorophenol red or monofluorocresol purple and intermolecularly in phenolphthalein (18)F-FDG mixtures. The probes were selectively quenched in the bandwidth closest to the indicator's absorption maximum (λmax) at pHs above the indicator pKa (the negative logarithm of the acid dissociation constant). Addition of acid or base to the probes resulted in reversible switching from unquenched to quenched emission. In vivo, the bladders of acetazolamide-treated mice exhibited a wavelength-dependent quenching in Cerenkov emission, with the greatest reduction occurring near the λmax. Ratiometric imaging at 2 wavelengths showed significant decreases in Cerenkov emission at basic pH and allowed the estimation

  7. Cerenkov specific contrast agents for detection of pH in vivo

    Science.gov (United States)

    Czupryna, Julie; Kachur, Alexander V.; Blankemeyer, Eric; Popov, Anatoliy V.; Karp, Joel S.; Delikatny, E. James

    2015-01-01

    We report the design, testing and in vivo application of pH sensitive contrast agents designed specifically for Cerenkov imaging. Radioisotopes used for positron emission tomography (PET) emit photons via Cerenkov radiation. The multispectral emission of Cerenkov radiation allows for selective bandwidth quenching, where a band of photons are quenched by absorption by a functional dye. Under acidic conditions, 18F-labeled derivatives emit the full spectrum of Cerenkov light. Under basic conditions, the dyes change color and a wavelength-dependent quenching of Cerenkov emission is observed. METHODS Mono and di-18F-labeled derivatives of phenolsulfonphthalein (phenol red) and meta-cresolsulfonphthalein (cresol purple) were synthesized by electrophilic fluorination. Cerenkov emission was measured at different wavelengths as a function of pH in vitro. Intramolecular response was measured in fluorinated probes; intermolecular quenching by mixing phenolphthalein with 18F FDG. Monofluorocresol purple (MFCP) was tested in mice treated with acetazolamide to cause urinary alkalinization and Cerenkov images compared to PET images. RESULTS Fluorinated pH indicators were produced with radiochemical yields of 4-11% at >90% purity. Selective Cerenkov quenching was observed intramolecularly with difluorophenol red or MFCP, and intermolecularly in phenolphthalein 18F-FDG mixtures. The probes were selectively quenched in the bandwidth closest to the indicator’s absorption maximum (λmax) at pHs above the indicator pKa. Addition of acid or base to the probes resulted in reversible switching from unquenched to quenched emission. In vivo, the bladders of acetazolamide-treated mice exhibited a wavelength-dependent quenching in Cerenkov emission, with the greatest reduction occurring near the λmax. Ratiometric imaging at two wavelengths showed significant decreases in Cerenkov emission at basic pH and allowed the estimation of absolute pH in vivo. CONCLUSIONS We have created contrast

  8. Disseminated intravascular coagulation in sepsis

    NARCIS (Netherlands)

    Zeerleder, Sacha; Hack, C. Erik; Wuillemin, Walter A.

    2005-01-01

    Disseminated intravascular coagulation is a frequent complication of sepsis. Coagulation activation, inhibition of fibrinolysis, and consumption of coagulation inhibitors lead to a procoagulant state resulting in inadequate fibrin removal and fibrin deposition in the microvasculature. As a

  9. Estrogen receptor targeted contrast agents for molecular magnetic resonance imaging of breast cancer hormonal status

    Directory of Open Access Journals (Sweden)

    Adi ePais

    2016-04-01

    Full Text Available The estrogen receptor α (ER is over expressed in most breast cancers and its level serves as a major prognostic factor. It is important to develop quantitative molecular imaging methods that specifically detect ER in vivo and assess its function throughout the entire primary breast cancer, as well as in metastatic breast cancer lesions. This study presents the biochemical and molecular features, as well as the magnetic resonance imaging effects of two novel ER- targeted contrast agents (CAs based on pyridine-tetra-acetate-Gd(III chelate conjugated to 17β-estradiol (EPTA-Gd or to tamoxifen (TPTA-Gd. The experiments were conducted in solution, in human breast cancer cells and in severe combined immunodeficient mice implanted with transfected ER-positive and ER-negative MDA-MB-231 human breast cancer xenografts. Binding studies with ER in solution and in human breast cancer cells indicated affinities in the micromolar range of both CAs. Biochemical and molecular studies in breast cancer cell cultures showed that both CAs exhibit estrogen like agonistic activity, enhancing cell proliferation, as well as up-regulating cMyc oncogene and down-regulating ER expression levels. The MRI longitudinal relaxivity was significantly augmented by EPTA-Gd in ER-positive cells as compared to ER-negative cells. Dynamic contrast enhanced studies with EPTA-Gd in vivo indicated specific augmentation of the MRI water signal in the ER-positive versus ER-negative xenografts, confirming EPTA-Gd specific interaction with ER. In contrast, TPTA-Gd did not show increased enhancement in ER-positive tumors and did not appear to interact in vivo with the tumors’ ER. However, TPTA-Gd was found to interact strongly with muscle tissue, enhancing muscle signal intensity in a mechanism independent of the presence of ER. The specificity of EPTA-Gd interaction with ER in vivo was further verified by acute and chronic competition with tamoxifen. The chronic tamoxifen treatment also

  10. In vivo dentate nucleus MRI relaxometry correlates with previous administration of Gadolinium-based contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Tedeschi, Enrico; Canna, Antonietta; Cocozza, Sirio; Russo, Carmela; Angelini, Valentina; Brunetti, Arturo [University ' ' Federico II' ' , Neuroradiology, Department of Advanced Biomedical Sciences, Naples (Italy); Palma, Giuseppe; Quarantelli, Mario [National Research Council, Institute of Biostructure and Bioimaging, Naples (Italy); Borrelli, Pasquale; Salvatore, Marco [IRCCS SDN, Naples (Italy); Lanzillo, Roberta; Postiglione, Emanuela; Morra, Vincenzo Brescia [University ' ' Federico II' ' , Department of Neurosciences, Reproductive and Odontostomatological Sciences, Naples (Italy)

    2016-12-15

    To evaluate changes in T1 and T2* relaxometry of dentate nuclei (DN) with respect to the number of previous administrations of Gadolinium-based contrast agents (GBCA). In 74 relapsing-remitting multiple sclerosis (RR-MS) patients with variable disease duration (9.8±6.8 years) and severity (Expanded Disability Status Scale scores:3.1±0.9), the DN R1 (1/T1) and R2* (1/T2*) relaxation rates were measured using two unenhanced 3D Dual-Echo spoiled Gradient-Echo sequences with different flip angles. Correlations of the number of previous GBCA administrations with DN R1 and R2* relaxation rates were tested, including gender and age effect, in a multivariate regression analysis. The DN R1 (normalized by brainstem) significantly correlated with the number of GBCA administrations (p<0.001), maintaining the same significance even when including MS-related factors. Instead, the DN R2* values correlated only with age (p=0.003), and not with GBCA administrations (p=0.67). In a subgroup of 35 patients for whom the administered GBCA subtype was known, the effect of GBCA on DN R1 appeared mainly related to linear GBCA. In RR-MS patients, the number of previous GBCA administrations correlates with R1 relaxation rates of DN, while R2* values remain unaffected, suggesting that T1-shortening in these patients is related to the amount of Gadolinium given. (orig.)

  11. ABC protein transport of MRI contrast agents in canalicular rat liver plasma vesicles and yeast vacuoles

    International Nuclear Information System (INIS)

    Pascolo, Lorella; Petrovic, Sinisa; Cupelli, Felicia; Bruschi, Carlo V.; Anelli, Pier Lucio; Lorusso, Vito; Visigalli, Massimo; Uggeri, Fulvio; Tiribelli, Claudio

    2001-01-01

    The mechanism of excretion into bile of hepatospecific magnetic resonance imaging (MRI) contrast media employed labeled Gd-reagents EOB.DTPA, BOPTA, B 20790 (iopanoate-linked), and B 21690 (glycocholate-linked) for measurement in rat liver canalicular plasma membrane vesicles and yeast vacuoles. The presence of ATP gave threefold greater transport of B 20790 and B 21690 than of EOB.DTPA and BOPTA. In yeast vacuoles the ATP stimulatory effect was eightfold with B 20790 and fivefold greater for B 21690, whereas in YCF1- or YLLO115w-deleted yeast cells the transport was significantly reduced and absent from double mutants, YCF1 and YLLO15w. The transport was similar in wild-type and deletant cells for B 21690; taurocholate gave 85% inhibition. These data suggest that bilary secretion of structurally related MRI agents depend on molecular structure. The findings are suggestive as of possible value for clinical diagnosis of inherited hyperbilirubinemias and other liver disorders

  12. Streaming flow from ultrasound contrast agents by acoustic waves in a blood vessel model.

    Science.gov (United States)

    Cho, Eunjin; Chung, Sang Kug; Rhee, Kyehan

    2015-09-01

    To elucidate the effects of streaming flow on ultrasound contrast agent (UCA)-assisted drug delivery, streaming velocity fields from sonicated UCA microbubbles were measured using particle image velocimetry (PIV) in a blood vessel model. At the beginning of ultrasound sonication, the UCA bubbles formed clusters and translated in the direction of the ultrasound field. Bubble cluster formation and translation were faster with 2.25MHz sonication, a frequency close to the resonance frequency of the UCA. Translation of bubble clusters induced streaming jet flow that impinged on the vessel wall, forming symmetric vortices. The maximum streaming velocity was about 60mm/s at 2.25MHz and decreased to 15mm/s at 1.0MHz for the same acoustic pressure amplitude. The effect of the ultrasound frequency on wall shear stress was more noticeable. Maximum wall shear stress decreased from 0.84 to 0.1Pa as the ultrasound frequency decreased from 2.25 to 1.0MHz. The maximum spatial gradient of the wall shear stress also decreased from 1.0 to 0.1Pa/mm. This study showed that streaming flow was induced by bubble cluster formation and translation and was stronger upon sonication by an acoustic wave with a frequency near the UCA resonance frequency. Therefore, the secondary radiant force, which is much stronger at the resonance frequency, should play an important role in UCA-assisted drug delivery. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Synthesis and evaluation of novel polysaccharide-Gd-DTPA compounds as contrast agent for MRI

    Science.gov (United States)

    Sun, Guoying; Feng, Jianghua; Jing, Fengying; Pei, Fengkui; Liu, Maili

    2003-09-01

    Macromolecular conjugates of two kinds of natural polysaccharides, that from Panax quinquefolium linn (PQPS) and Ganoderma applanatum pat (GAPS), with gadolinium-diethylenetriaminepenta-acetic acid (Gd-DTPA) have been synthesized and characterized by means of FTIR, elementary analysis and ICP-AES. Their stability was investigated by competition study with Ca 2+, EDTA (ethylenediaminetetraacetic acid) and DTPA. Polysaccharide-bound complexes exhibit T1 relaxivities of 1.5-1.7 times that of Gd-DTPA in D 2O at 25°C and 9.4 T. MR imaging of Sprague-Dawley (SD) rats showed remarkable enhancement in rat liver and kidney after i.v. injection of these two complexes: liver parenchyma 60.9±5.6%, 57.8±7.4% at 65-85 min; kidney 144.9±14.5%, 199.9±25.4% at 10-30 min for PQPS-Gd-DTPA, GAPS-Gd-DTPA at gadolinium dose of 0.083 and 0.082 mmol/kg, respectively. Our preliminary in vivo and in vitro study indicates that the two kinds of polysaccharide-bound complexes are potential tissue-specific contrast agents for MRI.

  14. Angiographic CT with intravenous contrast agent application for monitoring of intracranial flow diverting stents

    International Nuclear Information System (INIS)

    Saake, Marc; Struffert, Tobias; Goelitz, Philipp; Ott, Sabine; Doerfler, Arnd; Seifert, Frank; Ganslandt, Oliver

    2012-01-01

    Intracranial flow diverting devices are increasingly used to treat cerebral aneurysms. A reliable, non-invasive follow-up modality would be desirable. Our aim was to compare intra-arterial digital subtraction angiography (ia DSA) to angiographic computed tomography with intravenous contrast agent application (iv ACT) in the visualisation of flow diverting devices and aneurysm lumina. Follow-up monitoring by iv ACT (n = 36) and ia DSA (n = 25) in 14 patients treated with flow diverting devices for intracranial aneurysms was evaluated retrospectively. Images were evaluated by two neuroradiologists in anonymous consensus reading regarding the device deployment, wall apposition, neck coverage of the aneurysm, opacification of the vessel and device lumen, as well as the degree of aneurysm occlusion. Corresponding ia DSA and iv ACT images were scored identically in all patients regarding the stent deployment, wall apposition and neck coverage, as well as the degree of aneurysm occlusion and patency status of the device and parent artery. Opacification of the parent vessel lumen and perfused parts of the aneurysm was considered slightly inferior for iv ACT in comparison with ia DSA (seven of 36 cases), without impact on diagnosis. We demonstrated the feasibility and diagnostic value of iv ACT in follow-up imaging of intracranial flow diverting devices. Due to its high spatial resolution and non-invasive character, this novel technique might become a valuable imaging modality in these patients. (orig.)

  15. Gd (III) chelates adsorbed on TiO2 nanoparticles - promising MRI contrast agent

    International Nuclear Information System (INIS)

    Rehor, Ivan; Lukes, Ivan; Peters, Joop A.; Jirak, Daniel

    2009-01-01

    Full text: The project deals with a new contrast agent (CA) for magnetic resonance imaging (MRI). The CA consists of two main parts - diamagnetic core (TiO 2 nanoparticle) and Gd (III) chelates grafted on its surface. The presence of the nanoparticle core is responsible for significant increase of r1 millimolar relaxivity (which corresponds to the efficiency of the CA) due to the slowing down the rotation of the complex in solution. It also affects the biodistribution characteristics of the CA - the ability to penetrate through cell membranes is well known for nanoparticles, making them useful for cell labeling. The structure of the chelate is derived from DOTA ligand, whose Gd (III) complexes are commercially used as MRI CA in human medicine. The connection of the complex to the surface is realized via penylphosphonate, which is attached to the pendant arm of the ligand. Strong interaction of the phosphonate with the TiO 2 surface results in the full surface coverage. The complexation and MRI properties of Gd chelate were studied and exhibit analogy to the complexes of DOTA, The millimolar relaxivity (r1) of the Gd (III) complex significantly increases upon adsorption on the TiO 2 nanoparticles. PVA was added to the colloidal solutions of CA to stabilize them under biological conditions and such stabilized CA was utilized for MRI visualization of rat pancreatic islets (P1). The labeled islets were detected on MR images as hyperintense area and therefore our CA seems to be promising material for cellular MRI

  16. Engineering erythrocytes for the modulation of drugs' and contrasting agents' pharmacokinetics and biodistribution.

    Science.gov (United States)

    Rossi, Luigia; Pierigè, Francesca; Antonelli, Antonella; Bigini, Noemi; Gabucci, Claudia; Peiretti, Enrico; Magnani, Mauro

    2016-11-15

    Pharmacokinetics, biodistribution, and biological activity are key parameters that determine the success or failure of therapeutics. Many developments intended to improve their in vivo performance, aim at modulating concentration, biodistribution, and targeting to tissues, cells or subcellular compartments. Erythrocyte-based drug delivery systems are especially efficient in maintaining active drugs in circulation, in releasing them for several weeks or in targeting drugs to selected cells. Erythrocytes can also be easily processed to entrap the desired pharmaceutical ingredients before re-infusion into the same or matched donors. These carriers are totally biocompatible, have a large capacity and could accommodate traditional chemical entities (glucocorticoids, immunossuppresants, etc.), biologics (proteins) and/or contrasting agents (dyes, nanoparticles). Carrier erythrocytes have been evaluated in thousands of infusions in humans proving treatment safety and efficacy, hence gaining interest in the management of complex pathologies (particularly in chronic treatments and when side-effects become serious issues) and in new diagnostic approaches. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Acoustic interrogation and optical visualization of ultrasound contrast agents within microcapsules.

    Science.gov (United States)

    Santhiranayagam, P; Thirumalai, S; Memom, F; Shan, Y; Lee, S J; Mobed-Miremadi, M; Keralapura, M

    2012-01-01

    The effectiveness of localized drug delivery as a treatment for breast cancer requires sufficiently high therapeutic dose, as well as an ability to image the drug for proper spatial targeting. To balance treatment potential and imaging capabilities, we have begun to design a novel drug reservoir using microcapsules that are large in size (> 30 µm) but functionalized with microbubbles or ultrasound contrast agents (UCAs). We term these carriers as 'Acoustically Sensitive Microcapsules' (ASMs). In previous work, we have demonstrated preparation of ASM carriers and their structural changes under therapeutic ultrasound by imaging static changes. In this paper, we describe a combined optical-acoustic setup coupled with a microfluidic device to trap these carriers for imaging and sonication. Using the setup, continuous wave ultrasound (180 kPa, 2.25 MHz, 3 s) produced an average displacement of 3.5 µm in UCAs near the ASM boundary, and exhibited displacement as high as 90 µm near the center of the microcapsule. Longer exposure time and higher acoustic pressure increased UCA displacement within an ASM. These two parameters can be carefully optimized in the future to cause these UCAs to travel to the membrane boundary to help in the drug elution process.

  18. Magnetic and relaxometric properties of polyethylenimine-coated superparamagnetic MRI contrast agents

    International Nuclear Information System (INIS)

    Corti, M.; Lascialfari, A.; Marinone, M.; Masotti, A.; Micotti, E.; Orsini, F.; Ortaggi, G.; Poletti, G.; Innocenti, C.; Sangregorio, C.

    2008-01-01

    Novel systems to be employed as superparamagnetic contrast agents (CA) for magnetic resonance imaging (MRI) have been synthesized. These compounds are composed of an iron oxide magnetic core coated by polyethylenimine (PEI) or carboxylated polyethylenimine (PEI-COOH). The aim of the present work was to prepare and study new nanostructured systems (with better or at least comparable relaxivities, R 1 and R 2 , with respect to the commercial ones) with controlled, almost monodisperse average dimensions and shape, as candidates for molecular targeting. By means of atomic force microscopy (AFM) measurements we determined the average diameter, of the order of 200 nm, and the shape of the particles. The superparamagnetic behavior was assessed by SQUID measurements. From X-ray data the estimated average diameters of the magnetic cores were found to be ∼5.8 nm for PEI-COOH60 and ∼20 nm for the compound named PEI25. By NMR-dispersion (NMRD), we found that PEI-COOH60 presents R 1 and R 2 relaxivities slightly lower than Endorem. The experimental results suggest that these novel compounds can be used as MRI CA

  19. A temporal study of ultrasound contrast agent-induced changes in capillary density.

    Science.gov (United States)

    Johnson, Chenara A; Sarwate, Sandhya; Miller, Rita J; O'Brien, William D

    2010-09-01

    The ability of ultrasound (US) and ultrasound contrast agents (UCAs) to induce angiogenesis has been explored as a means of restoring blood flow to ischemic muscle. Because UCAs demonstrate an increasing percentage of collapse cavitation with increasing US pressure (Pr), this study sought to explore the effects of a US Pr that produces 100% collapse cavitation, determine the capillary density changes, and determine the time point of angiogenic rebound in a normal animal model. Using a 1-MHz focused transducer and a peak rarefactional US Pr of 3.8 MPa, rat gracilis muscles were exposed to US, and bioeffects were assessed. Capillary density, as a measure of angiogenesis, was examined. As an additional measure, inflammatory cells were quantified via a color threshold analysis to detect the presence of CD31 and CD34 as a percentage of the total section on stained slides. Six groups (0, 3, 6, 13, 20, and 27 days postexposure [DPE]; n = 3 each) and 5 cage controls were used to characterize the angiogenic response. Ultrasound-UCA treatment caused the capillary density to decrease acutely (0 DPE) by 70% and inflammatory cells to increase by up to 250%. The angiogenic rebound was observed at 3 DPE but did not return to control levels by 27 DPE, suggesting an incomplete healing response. Capillary destruction and inflammation played an important role in the angiogenic response induced by US-UCA. Exposure that causes 100% collapse cavitation causes capillary destruction from which normal rats are unable to recover and suggests a nontherapeutic effect.

  20. Polyol synthesis, functionalisation, and biocompatibility studies of superparamagnetic iron oxide nanoparticles as potential MRI contrast agents.

    Science.gov (United States)

    Hachani, Roxanne; Lowdell, Mark; Birchall, Martin; Hervault, Aziliz; Mertz, Damien; Begin-Colin, Sylvie; Thanh, Nguyen Thi Kim

    2016-02-14

    Iron oxide nanoparticles (IONPs) of low polydispersity were obtained through a simple polyol synthesis in high pressure and high temperature conditions. The control of the size and morphology of the nanoparticles was studied by varying the solvent used, the amount of iron precursor and the reaction time. Compared with conventional synthesis methods such as thermal decomposition or co-precipitation, this process yields nanoparticles with a narrow particle size distribution in a simple, reproducible and cost effective manner without the need for an inert atmosphere. For example, IONPs with a diameter of ca. 8 nm could be made in a reproducible manner and with good crystallinity as evidenced by X-ray diffraction analysis and high saturation magnetization value (84.5 emu g(-1)). The surface of the IONPs could be tailored post synthesis with two different ligands which provided functionality and stability in water and phosphate buffer saline (PBS). Their potential as a magnetic resonance imaging (MRI) contrast agent was confirmed as they exhibited high r1 and r2 relaxivities of 7.95 mM(-1) s(-1) and 185.58 mM(-1) s(-1) respectively at 1.4 T. Biocompatibility and viability of IONPs in primary human mesenchymal stem cells (hMSCs) was studied and confirmed.

  1. Preparation and Characterization of Ion-Irradiated Nanodiamonds as Photoacoustic Contrast Agents.

    Science.gov (United States)

    Fang, Chia-Yi; Chang, Cheng-Chun; Mou, Chung-Yuan; Chang, Huan-Cheng

    2015-02-01

    Highly radiation-damaged or irradiated nanodiamonds (INDs) are a new type of nanomaterial developed recently as a potential photoacoustic (PA) contrast agent for deep-tissue imaging. This work characterized in detail the photophysical properties of these materials prepared by ion irradiation of natural diamond powders using various spectroscopic methods. For 40-nm NDs irradiated with 40-keV He+ at a dose of 3 x 10(15) ions/cm2, an average molar extinction coefficient of 4.2 M-1 cm-1 per carbon atom was measured at 1064 nm. Compared with gold nanorods of similar dimensions (10 nm x 67 nm), the INDs have a substantially smaller (by > 4 orders of magnitude) molar extinction coefficient per particle. However, the deficit is readily compensated by the much higher thermal stability, stronger hydrophilic interaction with water, and a lower nanobubble formation threshold (~30 mJ/cm2) of the sp3-carbon-based nanomaterial. No sign of photodamage was detected after high-energy (>100 mJ/cm2) illumination of the INDs for hours. Cell viability assays at the IND concentration of up to 100 µg/mL showed that the nanomaterial is non-cytotoxic and potentially useful for long-term PA bioimaging applications.

  2. Self-Assembled Polyelectrolyte Nanoparticles as Fluorophore-Free Contrast Agents for Multicolor Optical Imaging

    Directory of Open Access Journals (Sweden)

    Da Hye Shin

    2015-03-01

    Full Text Available In this work, we describe the fabrication of self-assembled polyelectrolyte nanoparticles that provide a multicolor optical imaging modality. Poly(γ-glutamic acid(γ-PGA formed self-assembled nanoparticles through electrostatic interactions with two different cationic polymers: poly(L-lysine(PLL and chitosan. The self-assembled γ-PGA/PLL and γ-PGA/chitosan nanoparticles were crosslinked by glutaraldehyde. Crosslinking of the ionic self-assembled nanoparticles with glutaraldehyde not only stabilized the nanoparticles but also generated a strong autofluorescence signal. Fluorescent Schiff base bonds (C=N and double bonds (C=C were generated simultaneously by crosslinking of the amine moiety of the cationic polyelectrolytes with monomeric glutaraldehyde or with polymeric glutaraldehyde. The unique optical properties of the nanoparticles that resulted from the crosslinking by glutaraldehyde were analyzed using UV/Vis and fluorescence spectroscopy. We observed that the fluorescence intensity of the nanoparticles could be regulated by adjusting the crosslinker concentration and the reaction time. The nanoparticles also exhibited high performance in the labeling and monitoring of therapeutic immune cells (macrophages and dendritic cells. These self-assembled nanoparticles are expected to be a promising multicolor optical imaging contrast agent for the labeling, detection, and monitoring of cells.

  3. Evaluation of MR lymphography with positive lymphotropic contrast agent in diagnosing lymph node lesions

    International Nuclear Information System (INIS)

    Zhou Zhengyang; Yu Haiping; Chen Junkun; Zhu Bin

    2010-01-01

    Objective: To evaluate the interstital MR lymphography using positive lymphotropic contrast agent for differentiation of metastatic lymph nodes from inflammatory lymph nodes hyperplasm. Methods: Eighteen New Zealand white rabbits weighted at 2. 0-2. 5 kg were used. Inflammatory hyperplastic popliteal lymph node model was established in 9 rabbits by injection of complete freund adjuvant into the interdigitial skin of the dorsal aspect of one hind leg, and tumor-bearing popliteal lymph node model was established in another 9 rabbits by injection of VX2 tumor cell suspension. The popliteal lymph nodes of another hind leg of all 18 rabbits were assigned to the normal contral group. In each group, every rabbit underwent MR lymphography examination before and after the inoculation. Volumes of 0.2 ml of Gd [ DTPA-bis ( 2-aminoethoxy ) ethane ] polymeric contrast agent ( Gd-poly-DTPA-EOEA ) injection were injected subcutaneously into the dorsal feet of both hind legs of two groups of rabbits. T 1 -weighted 3D gradient-echo images were obtained, and source images were used to reconstruct images of MIP before and after the administration of agent. The maximum short-axis diameter (MSAD) of each popliteal lymph node was measured on the enhanced 3D MIP images, and the signal-to-noise ratio (SNR) measurement was performed in the largest popliteal node of each rabbit at each time point in delayed scan. Independent- samples t test was used to compare the sizes of popliteal nodes in MSADs between inflammatorily hyperplastic and tumor-bearing nodes after the inoculation, and the values of SNRs of popliteal nodes at each time point between inflammatorily hyperplastic, tumor-bearing and normal popliteal lymph nodes. Imaging results of the popliteal nodes were analyzed and correlated with pathological findings. Results: All of the rabbits were successfully inoculated except of the 2 rabbits in tumor-bearing nodal group. The size in MSAD of 13 inflammatorily hyperplastic and 11 tumor

  4. Gadolinium Contrast Agent is of Limited Value for Magnetic Resonance Imaging Assessment of Synovial Hypertrophy in Hemophiliacs

    Energy Technology Data Exchange (ETDEWEB)

    Lundin, B.; Berntorp, E.; Pettersson, H.; Wirestam, R.; Jonsson, K.; Staahlberg, F.; Ljung, R. [Dept. of Radiology, Univ Hospital of Lund, Lund (Sweden)

    2007-07-15

    Purpose: To examine the influence of different doses of gadolinium contrast agent on synovial enhancement, to compare magnetic resonance imaging (MRI) findings of synovial hypertrophy and radiographic joint changes in hemophiliacs, and to investigate the value of gadolinium in MRI assessment of synovial hypertrophy in hemophiliacs using dynamic MRI and MRI scoring. Material and Methods: Twenty-one hemophiliacs on prophylactic factor treatment without recent bleeds were subjected to radiography and gadolinium contrast-enhanced dynamic and static MRI of the knee using a standard dose of 0.1 mmol/kg b.w. gadoteridol. In 17 of the patients, the MRI procedure was repeated after a triple dose of gadoteridol. Results: MRI findings of synovial hypertrophy were significantly correlated with Pettersson radiographic scores. In 19 of the 21 MRI investigated joints, administration of contrast agent did not alter the result of the evaluation of synovial hypertrophy. Conclusion: The optimal time interval for volume assessment of synovial hypertrophy after injection of gadolinium contrast agent is dose dependent. Hemophiliacs without recent bleeds have minor to abundant synovial hypertrophy in joints with pronounced radiographic changes. Dynamic MRI is not useful for evaluating hemophilic arthropathy, and gadolinium contrast agent is not routinely indicated for MRI scoring of joints in hemophiliacs.

  5. Brain tumours at 7T MRI compared to 3T - contrast effect after half and full standard contrast agent dose: initial results

    International Nuclear Information System (INIS)

    Noebauer-Huhmann, Iris-Melanie; Weber, M.; Szomolanyi, P.; Juras, V.; Kronnerwetter, C.; Widhalm, G.; Nemec, S.; Prayer, D.; Ladd, M.E.; Trattnig, S.

    2015-01-01

    To compare the contrast agent effect of a full dose and half the dose of gadobenate dimeglumine in brain tumours at 7 Tesla (7T) MR versus 3 Tesla (3T). Ten patients with primary brain tumours or metastases were examined. Signal intensities were assessed in the lesion and normal brain. Tumour-to-brain contrast and lesion enhancement were calculated. Additionally, two independent readers subjectively graded the image quality and artefacts. The enhanced mean tumour-to-brain contrast and lesion enhancement were significantly higher at 7T than at 3T for both half the dose (91.8 ± 45.8 vs. 43.9 ± 25.3 [p = 0.010], 128.1 ± 53.7 vs. 75.5 ± 32.4 [p = 0.004]) and the full dose (129.2 ± 50.9 vs. 66.6 ± 33.1 [p = 0.002], 165.4 ± 54.2 vs. 102.6 ± 45.4 [p = 0.004]). Differences between dosages at each field strength were also significant. Lesion enhancement was higher with half the dose at 7T than with the full dose at 3T (p =.037), while the tumour-to-brain contrast was not significantly different. Subjectively, contrast enhancement, visibility, and lesion delineation were better at 7T and with the full dose. All parameters were rated as good, at the least. Half the routine contrast agent dose at 7T provided higher lesion enhancement than the full dose at 3T which indicates the possibility of dose reduction at 7T. (orig.)

  6. Is the transport of a gadolinium-based contrast agent decreased in a degenerated or aged disc? A post contrast MRI study.

    Directory of Open Access Journals (Sweden)

    Marta Tibiletti

    Full Text Available A post contrast magnetic resonance imaging study has been performed in a wide population of low back pain patients to investigate which radiological and phenotypic characteristics influence the penetration of the contrast agent in lumbar discs in vivo. 37 patients affected by different pathologies (disc herniation, spondylolisthesis, foraminal stenosis, central canal stenosis were enrolled in the study. The selected population included 26 male and 11 female subjects, with a mean age of 42.4 ± 9.3 years (range 18-60. Magnetic resonance images of the lumbar spine were obtained with a 1.5 T scanner (Avanto, Siemens, Erlangen, Germany with a phased-array back coil. A paramagnetic non-ionic contrast agent was injected with a dose of 0.4 ml/kg. T1-weighted magnetic resonance images were subsequently acquired at 5 time points, 5 and 10 minutes, 2, 4 and 6 hours after injection. Endplates presented clear enhancement already 5 minutes after injection, and showed an increase in the next 2 hours followed by a decrease. At 5 and 10 minutes, virtually no contrast medium was present inside the intervertebral disc; afterwards, enhancement significantly increased. Highly degenerated discs showed higher enhancement in comparison with low and medium degenerated discs. Discs classified as Pfirrmann 5 showed a statistically significant higher enhancement than Pfirrmann 1, 2 and 3 at all time points but the first one, possibly due to vascularization. Disc height collapse and Modic changes significantly increased enhancement. Presence of endplate defects did not show any significant influence on post contrast enhancement, but the lack of a clear classification of endplate defects as seen on magnetic resonance scans may be shadowing some effects. In conclusion, disc height, high level of degeneration and presence of Modic changes are factors which increase post contrast enhancement in the intervertebral disc. The effect of age could not be demonstrated.

  7. Doppler ultrasound findings in healthy wrists and finger joints before and after use of two different contrast agents

    Science.gov (United States)

    Terslev, L; Torp-Pedersen, S; Bang, N; Koenig, M; Nielsen, M; Bliddal, H

    2005-01-01

    Objective: To examine the effect of contrast agents on Doppler ultrasound findings in the synovial membrane in the wrist and fingers of healthy volunteers. Material and methods: Eleven healthy subjects were included in the study (5 women and 6 men, mean age 38 years, range (20–60)). They had no clinical signs of inflammatory or degenerative joint diseases. A total of 66 joints were examined—6 joints for each subject: wrist and metacarpophalangeal (MCP) joints 1–5—before contrast injection and after Levovist and SonoVue injection with a 30 minute interval. Results: Colour Doppler activity was detected in 10/55 (18%) MCP joints before contrast injection and in 29/55 (53%) and 28/55 (51%) joints after Levovist (pSonoVue injection (p = 0.0001), respectively. A significant increase in Doppler activity in the radial (pSonoVue injections. With spectral Doppler no difference was found in the resistive index (RI) in the vessels measured before as compared with those only detected after contrast injection. Conclusion: The number of joints with colour Doppler activity in healthy volunteers was increased by the use of contrast agents. No changes in RI were detected. The value of contrast agents remains to be demonstrated in inflammatory diagnostics. PMID:15897304

  8. [Differential patterns of contrast enhancement in different focal liver lesions after injection of the microbubble US contrast agent SonoVue].

    Science.gov (United States)

    Quaia, Emilio; Degobbis, Francesca; Tona, Giuseppe; Mosconi, Elisa; Bertolotto, Michele; Pozzi Mucelli, Roberto

    2004-03-01

    To identify differential contrast enhancement patterns in different focal hepatic lesions after injection of the microbubble contrast agent SonoVue using high or low acoustic power imaging. Forty-seven focal hepatic lesions (1-8 cm) were detected in 45 patients at unenhanced gray-scale ultrasound (US) and evaluated by color Doppler (CD) US with spectral analysis of tumoral vessels. Lesions were subsequently evaluated by US contrast specific modes after IV bolus administration of 2,4-4,8 ml of SonoVue, by intermittent high acoustic power (18 patients) or by continous low acoustic power imaging (27 patients), during arterial, portal and late phase. Subjective evaluation of lesions appearance before and after SonoVue injection was performed. For final diagnosis multiphasic helical CT (21 patients) and/or fine needle US guided biopsy (24 patients) were considered as the reference procedures. Final diagnoses comprised 22 hepatocellular carcinomas (HCCs; 1,5-6 cm), 2 macroregenerative nodules (RNNs; 1-2 cm), 10 metastasis (2-3,5 cm), 10 hemangiomas (2-6 cm) and 3 focal nodular hyperplasias (FNHs; 1-3 cm). On CD evaluation HCCs revealed peripheral basket shaped (12/22) or intranodular (10/22) arterial pattern while, after SonoVue injection HCCs revealed diffuse contrast enhancement during arterial phase with contrast washout during portal and late phase. Metastases did not reveal flow signals on CD or contrast enhancement after SonoVue injection, except for 2 metastases which revealed peripheral and central vessels on CD and a diffuse contrast enhancement during arterial phase, appearing hypoechoic to the adjacent liver during portal and late phase. RNNs revealed dotted contrast-enhancement during portal and late phase with isoechoic appearance to the adjacent liver. Hemangiomas revealed some peripheral venous flows on CD and a peripheral nodular contrast enhancement during arterial phase with a centripetal fill-in during portal and late phase. FNHs revealed low

  9. Peritoneal and pleural fluids may appear hyperintense on hepatobiliary phase using hepatobiliary MR contrast agents.

    Science.gov (United States)

    Ciolina, Maria; Di Martino, Michele; Bruno, Onorina; Pommier, Romain; Vilgrain, Valérie; Ronot, Maxime

    2018-01-26

    To describe the effect of hepatobiliary-specific MR imaging contrast agent (HBCA) administration on the signal intensity of peritoneal and pleural fluid effusions on T1-weighted MR images. From October 2015 to May 2016 139 patients (mean 60±10 years old, 69 % males) with peritoneal or pleural effusions without biliary leakage who underwent HBCA-MRI (Gd-BOPTA or Gd-EOB-DTPA) at 1.5T and 3T were included from two centres. The fluid signal intensity was classified as hypo/iso/hyperintense before/after HBCA administration. The relative signal enhancement (RE) was calculated. On hepatobiliary phase (HBP), peritoneal fluids appeared hyper/isointense in 88-100 % and pleural effusions in 100 % of the patients following Gd-BOPTA administration. All fluids remained hypointense following Gd-EOB-DTPA. The signal intensity of fluids increased with both HBCA but RE was significantly higher following Gd-BOPTA (p=0.002 to fluids). The signal intensity of pleural and peritoneal fluids progressively increases following HBCA administration in the absence of biliary leakage. Due to its later hepatobiliary phase, this is more pronounced after Gd-BOPTA injection, leading to fluid hyperintensity that is not observed after Gd-EOB-DTPA injection. • Fluids appear hyper/isointense on HBP in most patients after Gd-BOPTA injection. • Fluids remain hypointense on HBP after Gd-EOB-DTPA injection. • RE of fluids increases with time after liver-specific Gd injection. • RE of fluids is higher in patients with chronic liver disease.

  10. Sonophoresis using ultrasound contrast agents for transdermal drug delivery: an in vivo experimental study.

    Science.gov (United States)

    Park, Donghee; Ryu, Heungil; Kim, Han Sung; Kim, Young-Sun; Choi, Kyu-Sil; Park, Hyunjin; Seo, Jongbum

    2012-04-01

    Sonophoresis temporally increases skin permeability such that various medications can be delivered noninvasively. Previous sonophoresis studies have suggested that cavitation plays an important role in enhancing transdermal drug delivery (TDD). In this study, the feasibility of controlled cavitation using ultrasound contrast agents (UCAs) at high frequency was explored through in vivo experiments in a rat model. Two commercially available UCAs, SonoVue® and Definity®, were used at 2.47 MHz and 1.12 MHz, respectively. Fluorescein isothiocyanate (FITC)-dextran with 0.1% UCA was used as the drug to be delivered through the skin. Ultrasound with a 10 ms pulse and a 1% duty cycle at 1 MPa acoustic pressure for 30 min was applied in all sonication sessions. The efficacy of sonophoresis with UCAs was quantitatively analyzed using an optical imaging system that was used to count photons emitted from fluorescein. The results showed that the proposed sonophoresis method significantly improved drug penetration compared with the traditional sonophoresis method with 4 kD, 20 kD and 150 kD FITC-dextrans at 1.12 MHz, and with 4 kD and 20 kD FITC-dextrans at 2.47 MHz. Sonophoresis for TDD was performed more effectively with the aid of UCAs. Sonophoresis with UCAs has excellent potential for broad applications in drug delivery for diseases requiring the chronic administration of medications such as diabetes. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. Micro-computed tomography of fatigue microdamage in cortical bone using a barium sulfate contrast agent.

    Science.gov (United States)

    Leng, Huijie; Wang, Xiang; Ross, Ryan D; Niebur, Glen L; Roeder, Ryan K

    2008-01-01

    Accumulation of microdamage during fatigue can lead to increased fracture susceptibility in bone. Current techniques for imaging microdamage in bone are inherently destructive and two-dimensional. Therefore, the objective of this study was to image the accumulation of fatigue microdamage in cortical bone using micro-computed tomography (micro-CT) with a barium sulfate (BaSO(4)) contrast agent. Two symmetric notches were machined on the tensile surface of bovine cortical bone beams in order to generate damage ahead of the stress concentrations during four-point bending fatigue. Specimens were loaded to a specified number of cycles or until one notch fractured, such that the other notch exhibited the accumulation of microdamage prior to fracture. Microdamage ahead of the notch was stained in vitro by precipitation of BaSO(4) and imaged using micro-CT. Reconstructed images showed a distinct region of bright voxels around the notch tip or along propagating cracks due to the presence of BaSO(4), which was verified by backscattered electron imaging and energy dispersive spectroscopy. The shape of the stained region ahead of the notch tip was consistent with principal strain contours calculated by finite element analysis. The relative volume of the stained region was correlated with the number of loading cycles by non-linear regression using a power-law. This study demonstrates new methods for the non-destructive and three-dimensional detection of fatigue microdamage accumulation in cortical bone in vitro, which may be useful to gain further understanding into the role of microdamage in bone fragility.

  12. Adverse allergic reactions to linear ionic gadolinium-based contrast agents: experience with 194, 400 injections.

    Science.gov (United States)

    Aran, S; Shaqdan, K W; Abujudeh, H H

    2015-05-01

    To report the authors' experience with the administration of four gadolinium-based contrast agents (GBCA; gadopentetate dimeglumine, gadofosveset trisodium, gadoxetate disodium and gadobenate dimeglumine) in a large study population at a single, large academic medical centre. The institutional review board approved this retrospective study in which data in the electronic incident reporting system were searched. A total of 194, 400 intravenous administrations of linear ionic GBCAs were assessed for the incidence of adverse reactions and risk factors from 1 January 2007 to 14 January 2014. The severity of reactions (mild, moderate, and severe), patient type (outpatients, inpatients, and emergency), examination type, and treatment options were also investigated. In total, 204/194400 (0.1%) patients (mean age 45.7 ± 14.9) showed adverse reactions, consisting of 6/746 (0.80%), 10/3200 (0.31%), 14/6236 (0.22%) and 174/184218 (0.09%), for gadofosveset trisodium, gadoxetate disodium, gadobenate dimeglumine, and gadopentetate dimeglumine, respectively. An overall significant difference was found between different GBCAs regarding the total number of reactions (p reaction was higher in females (F: 146/113187, 0.13%/M: 58/81213, 0.07%; p reactions was higher in outpatient (180/158885, 0.11%), emergency (10/10413, 0.10%), and inpatients (14/25102, 0.05%), respectively (p reactions (0.17 versus 0.16 versus 0.15). The overall rate of adverse reaction to GBCAs was 0.1%. The rates of reactions were highest in gadofosveset trisodium with (0.80%), followed by gadoxetate disodium (0.31%), gadobenate dimeglumine (0.22%) and gadopentetate dimeglumine (0.09%). Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Non-invasive estimation of blood pressure using ultrasound contrast agents

    Science.gov (United States)

    Andersen, Klaus Scheldrup; Jensen, Jørgen Arendt

    2010-01-01

    Local blood pressure measurements provide important information on the state of health of organs in the body and can be used to diagnose diseases in the heart, lungs, and kidneys. This paper presents an experimental setup for investigating the ambient pressure sensitivity of a contrast agent using diagnostic ultrasound. The setup resembles a realistic clinical setup utilizing a single array transducer for transmit and receive. The ambient pressure sensitivity of SonoVue (Bracco, Milano, Italy) was measured twice using two different acoustic driving pressures, which were selected based on a preliminary experiment. To compensate for variations in bubble response and to make the estimates more robust, the relation between the energy of the subharmonic and the fundamental component was chosen as a measure over the subharmonic peak amplitude. The preliminary study revealed the growth stage of the subharmonic component to occur at acoustic driving pressures between 300 and 500 kPa. Based on this, the pressure sensitivity was investigated using a driving pressure of 485 and 500 kPa. At 485 kPa, a linear pressure sensitivity of 0.42 dB/kPa was found having a linear correlation coefficient of 0.94. The second measurement series at 485 kPa showed a sensitivity of 0.41 dB/kPa with a correlation coefficient of 0.89. Based on the measurements at 500 kPa, this acoustic driving pressure was concluded to be too high causing the bubbles to be destroyed. The pressure sensitivity for these two measurement series were 0.42 and 0.25 dB/kPa with linear correlation coefficients of 0.98 and 0.93, respectively.

  14. Gold nanorods as a contrast agent for Doppler optical coherence tomography.

    Directory of Open Access Journals (Sweden)

    Bo Wang

    Full Text Available To investigate gold nanorods (GNRs as a contrast agent to enhance Doppler optical coherence tomography (OCT imaging of the intrascleral aqueous humor outflow.A serial dilution of GNRs was scanned with a spectral-domain OCT device (Bioptigen, Durham, NC to visualize Doppler signal. Doppler measurements using GNRs were validated using a controlled flow system. To demonstrate an application of GNR enhanced Doppler, porcine eyes were perfused at constant pressure with mock aqueous alone or 1.0×10(12 GNR/mL mixed with mock aqueous. Twelve Doppler and volumetric SD-OCT scans were obtained from the limbus in a radial fashion incremented by 30°, forming a circular scan pattern. Volumetric flow was computed by integrating flow inside non-connected vessels throughout all 12 scans around the limbus.At the GNR concentration of 0.7×10(12 GNRs/mL, Doppler signal was present through the entire depth of the testing tube without substantial attenuation. A well-defined laminar flow profile was observed for Doppler images of GNRs flowing through the glass capillary tube. The Doppler OCT measured flow profile was not statistically different from the expected flow profile based upon an autoregressive moving average model, with an error of -0.025 to 0.037 mm/s (p = 0.6435. Cross-sectional slices demonstrated the ability to view anterior chamber outflow ex-vivo using GNR-enhanced Doppler OCT. Doppler volumetric flow measurements were comparable to flow recorded by the perfusion system.GNRs created a measureable Doppler signal within otherwise silent flow fields in OCT Doppler scans. Practical application of this technique was confirmed in a constant pressure ex-vivo aqueous humor outflow model in porcine eyes.

  15. Nephrogenic systemic fibrosis associated with gadolinium based contrast agents: A summary of the medical literature reporting

    International Nuclear Information System (INIS)

    Broome, Dale R.

    2008-01-01

    Nephrogenic systemic fibrosis (NSF) is a systemic fibrosing disorder that principally affects the skin, but can involve virtually any tissue in the human body and result in significant disability and even death. Since 2006 numerous retrospective case reports and case series have reported a very strong association of this disease with exposure to gadolinium-based contrast agents (Gd-CA) for MR imaging in the setting of severe or end-stage renal disease. The purpose of this report is to summarize the medical literature reporting of biopsy-proven NSF cases in which the authors specifically investigated patient exposure to Gd-CA. A Pub Med MEDLINE search was performed using the key words-nephrogenic systemic fibrosis and nephrogenic fibrosing dermopathy. All case reports and case series of NSF were reviewed to determine if patients had a preceding exposure to Gd-CA and which specific Gd-CA was involved. If the original reports did not clarify the specific Gd-CA, I reviewed follow-up letters to the editors or contacted the authors to clarify which specific Gd-CA were linked to the NSF cases. If several reports originated from the same institution, clarification was also obtained to avoid redundant reporting. As of February 1, 2008 there have been 190 biopsy-proven cases of NSF published in the peer-reviewed literature with the following associations: 157 gadodiamide (Omniscan, GE Healthcare), 8 gadopentetate (Magnevist, Bayer Healthcare), 3 gadoversetamide (OptiMARK, Covidien), and 18 unspecified Gd-CA, and 4 confounded cases with more than one Gd-CA. Five cases of NSF were unassociated with Gd-CA

  16. Improved detection and biopsy of solid liver lesions using pulse-inversion ultrasound scanning and contrast agent infusion

    DEFF Research Database (Denmark)

    Skjoldbye, B.; Pedersen, Morten Høgholm; Struckmann, J.

    2002-01-01

    The purpose of this study was to assess the ability of pulse-inversion ultrasound (US) scanning (PIUS), combined with an IV contrast agent, to detect malignant liver lesions and its impact on patient management (resectability). Additionally, to determine the feasibility of US-guided biopsy of new...

  17. [Effect of Water Intake on Allergy-like Events Associated with Non-ionic Iodine Contrast Agents].

    Science.gov (United States)

    Motoi, Reiko; Yano, Ikuko; Ozaki, Junko; Hokoyama, Kanae; Yamamoto, Takashi; Fukatsu, Sachio; Ishizuka, Ryoko; Matsumura, Yumi; Taniguchi, Masahiro; Higashimura, Kyoji; Matsubara, Kazuo

    2015-01-01

    The use of iodine contrast agents occasionally causes serious allergic symptoms including anaphylaxis. At Kyoto University Hospital to prevent nephropathy we began recommending water intake before and after administration of iodine contrast agents in September 2012. In the present study we investigated the effect of water intake on the incidence of allergy-like events after the use of non-ionic iodine contrast agents. We extracted the occurrence of allergy-like events from the incident report system in our hospital from January 2011 to September 2014, and classified these events into the following 3 grades: 1+ (follow-up); 2+ (medication treatment); and 3+ (hospitalization). The allergy-like incidence rate was calculated for subsequent evaluation according to season and water intake. Allergy-like events significantly decreased from 0.49% before the recommendation of water intake to 0.26% at 1 year and 0.20% at 2 years after implementing the recommendation. The incidence of allergy-like events was significantly higher in summer than in winter before water intake was recommended. After implementing the recommendation, the value for summer significantly decreased to an incidence similar to that of winter. Respiratory and gastrointestinal allergy-like symptoms were dramatically decreased after implementing the recommendation. Water intake may be useful for preventing allergy-like events associated with non-ionic iodine contrast agents, especially during the summer.

  18. Positive-contrast cellular MRI of embryonic stem cells for tissue regeneration using a highly efficient T1MRI contrast agent.

    Science.gov (United States)

    Loai, Sadi; Haedicke, Inga; Mirzaei, Zahra; Simmons, Craig A; Zhang, Xiao-An; Cheng, Hai Ling

    2016-12-01

    To investigate the feasibility of high-sensitivity cellular MRI of embryonic stem (ES) cells using a novel cell permeable and cell retentive T 1 contrast agent. Mouse ES cells were labeled with a novel manganese porphyrin contrast agent, MnAMP, at 0.1 mM over 2 to 24 h and retained in contrast-free medium for up to 24 h postlabeling. MRI was performed on a 3 Tesla clinical scanner; T 1 and T 2 relaxation times were measured. Quantification of manganese content was performed using atomic absorption spectroscopy. Viability and proliferation assays were done for the longest labeling interval. Differentiation capacity was assessed using the hanging drop method to direct differentiation toward cardiomyocytes. MnAMP-labeled ES cells exhibited over a fourfold decrease in T 1 compared with unlabeled cells, and maintained up to a threefold decrease 24 h postlabeling. Viability and proliferation were not affected. Most importantly, labeled ES cells differentiated into functional cardiomyocytes that exhibited normal contractility patterns. MnAMP-based cellular MRI is a very high sensitivity T 1 approach for cellular imaging. It has the potential for noninvasive in vivo monitoring of stem cell therapy in cardiac regeneration and other tissue engineering and regenerative medicine applications. J. Magn. Reson. Imaging 2016;44:1456-1463. © 2016 International Society for Magnetic Resonance in Medicine.

  19. Evaluation of pharmacokinetic models for perfusion imaging with dynamic contrast-enhanced magnetic resonance imaging in porcine skeletal muscle using low-molecular-weight contrast agents.

    Science.gov (United States)

    Hindel, Stefan; Papanastasiou, Giorgos; Wust, Peter; Maaß, Marc; Söhner, Anika; Lüdemann, Lutz

    2018-06-01

    Pharmacokinetic models for perfusion quantification with a low-molecular-weight contrast agent (LMCA) in skeletal muscle using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) were evaluated. Tissue perfusion was measured in seven regions of interest (ROIs) placed in the total hind leg supplied by the femoral artery in seven female pigs. DCE-MRI was performed using a 3D gradient echo sequence with k-space sharing. The sequence was acquired twice, first after LMCA and then after blood pool contrast agent injection. Blood flow was augmented by continuous infusion of the vasodilator adenosine into the femoral artery, resulting in up to four times increased blood flow. The results obtained with several LMCA models were compared with those of a two-compartment blood pool model (2CBPM) consisting of a capillary and an arteriolar compartment. Measurements performed with a Doppler flow probe placed at the femoral artery served as ground truth. The two-compartment exchange model extended by an arteriolar compartment (E2CXM) showed the highest fit quality of all LMCA models and the most significant correlation with the Doppler measurements, r = 0.78 (P Reson Med 79:3154-3162, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  20. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang [The First Affiliated Hospital of Zhengzhou University, Department of Radiology, Zhengzhou, Henan Province (China)

    2017-01-15

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80) each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. (orig.)

  1. Evaluation of bias voltage modulation sequence for nonlinear contrast agent imaging using a capacitive micromachined ultrasonic transducer array

    Science.gov (United States)

    Novell, Anthony; Legros, Mathieu; Grégoire, Jean-Marc; Dayton, Paul A.; Bouakaz, Ayache

    2014-09-01

    Many clinical diagnoses have now been improved thanks to the development of new techniques dedicated to contrast agent nonlinear imaging. Over the past few years, Capacitive Micromachined Ultrasonic Transducers (cMUTs) have emerged as a promising alternative to traditional piezoelectric transducers. One notable advantage of cMUTs is their wide frequency bandwidth. However, their use in nonlinear imaging approaches such as those used to detect contrast agents have been challenging due their intrinsic nonlinear character. We propose a new contrast imaging sequence, called bias voltage modulation (BVM), specifically developed for cMUTs to suppress their inherent nonlinear behavior. Theoretical and experimental results show that a complete cancellation of the nonlinear signal from the source can be reached when the BVM sequence is implemented. In-vitro validation of the sequence is performed using a cMUT probe connected to an open scanner and a flow phantom setup containing SonoVue microbubbles. Compared to the standard amplitude modulation imaging mode, a 6 dB increase of contrast-to-tissue ratio was achieved when the BVM sequence is applied. These results reveal that the problem of cMUT nonlinearity can be addressed, thus expanding the potential of this new transducer technology for nonlinear contrast agent detection and imaging.

  2. Evaluation of bias voltage modulation sequence for nonlinear contrast agent imaging using a capacitive micromachined ultrasonic transducer array

    International Nuclear Information System (INIS)

    Novell, Anthony; Grégoire, Jean-Marc; Bouakaz, Ayache; Legros, Mathieu; Dayton, Paul A

    2014-01-01

    Many clinical diagnoses have now been improved thanks to the development of new techniques dedicated to contrast agent nonlinear imaging. Over the past few years, Capacitive Micromachined Ultrasonic Transducers (cMUTs) have emerged as a promising alternative to traditional piezoelectric transducers. One notable advantage of cMUTs is their wide frequency bandwidth. However, their use in nonlinear imaging approaches such as those used to detect contrast agents have been challenging due their intrinsic nonlinear character. We propose a new contrast imaging sequence, called bias voltage modulation (BVM), specifically developed for cMUTs to suppress their inherent nonlinear behavior. Theoretical and experimental results show that a complete cancellation of the nonlinear signal from the source can be reached when the BVM sequence is implemented. In-vitro validation of the sequence is performed using a cMUT probe connected to an open scanner and a flow phantom setup containing SonoVue microbubbles. Compared to the standard amplitude modulation imaging mode, a 6 dB increase of contrast-to-tissue ratio was achieved when the BVM sequence is applied. These results reveal that the problem of cMUT nonlinearity can be addressed, thus expanding the potential of this new transducer technology for nonlinear contrast agent detection and imaging. (paper)

  3. Examining The Effect of Iodized Contrast Agent of Coronary Heart Angiography in People Without Thyroid Gland Disorders

    Directory of Open Access Journals (Sweden)

    Marzieh Moradirizi

    2016-10-01

    Full Text Available Background: Iodine has a significant effect on thyroid function. A dose of 200 ml of contrast agent contains 35 mg/ml equivalent of 7000 Mg of free iodine and 45 times of the recommended daily dose. This high dose can cause a sudden loss of iodine adjustment, thyroid hormone synthesis, and impair the function of the thyroid gland. Methods: This study is a cross-sectional study (descriptive - analytical conducted in census method on 70 patients including 40 men and 30 women referring to Hajar medical education hospital for coronary angiography. Thyroid function tests were given before and after receiving the contrast agent angiography and the changes were finally analyzed. Results: In this study, after receiving iodinated contrast agent, 8 out of 70 cases studied significantly suffered subclinical hypothyroidism and no one suffered overt hypothyroidism or hypothyroidism. In terms of distribution based on age, there was no significant difference between different age groups in the intensity of hypothyroidism. In terms of gender distribution, from among 70 cases studied, 40 were men, of whom three suffered subclinical hypothyroidism. Thirty of the subjects were women, of whom five persons suffered subclinical hypothyroidism. Conclusion: The results show that angiography contrast agent can have effects on the thyroid function of the people with euthyroid, so that out of the 70 patients studied, all of whom were euthyroid, eight patients suffered subclinical hypothyroidism. (p=0.018. Moreover, the age and sex of the participants had no effects on thyroid disorder after receiving angiography contrast agent (P=0.5.

  4. Synthesis of highly stable and biocompatible gold nanoparticles for use as a new X-ray contrast agent.

    Science.gov (United States)

    Iranpour, Pooya; Ajamian, Maral; Safavi, Afsaneh; Iranpoor, Nasser; Abbaspour, Abdolkarim; Javanmardi, Sanaz

    2018-04-18

    This work reports a novel reduction procedure for the synthesis of Gum Arabic (GA) capped-gold nanoparticles (AuNPs) in glucosammonium formate as a new ionic liquid. The GA coated AuNPs show good stability in physiological media. The synthesized AuNPs were characterized by UV-Vis spectroscopy, transmission electron microscopy, dynamic light scattering and X-ray diffraction analysis. These stable AuNPs are introduced as a new contrast agent for X-ray Computed Tomography (X-ray CT). These nanoparticles have higher contrasting properties than the commercial contrast agent, Visipaque. The precursors used (Gum Arabic and glucose based-ionic liquid) for synthesis of AuNPs are biocompatible and non-toxic.

  5. The dynamic of FUS-induced BBB Opening in Mouse Brain assessed by contrast enhanced MRI

    Science.gov (United States)

    Jenne, Jürgen W.; Krafft, Axel J.; Maier, Florian; Krause, Marie N.; Kleber, Susanne; Huber, Peter E.; Martin-Villalba, Ana; Bock, Michael

    2010-03-01

    Focused ultrasound (FUS) in combination with the administration of gas-filled microbubbles, can induce a localized and reversible opening of the blood brain barrier (BBB). Contrast enhanced magnetic resonance imaging (MRI) has been demonstrated as a precise tool to monitor such a local BBB disruption. However, the opening/closing mechanisms of the BBB with FUS are still largely unknown. In this ongoing project, we study the BBB opening dynamics in mouse brain comparing an interstitial and an intravascular MR contrast agent (CA). FUS in mouse brain was performed with an MRI compatible treatment setup (1.7 MHz fix-focus US transducer, f' = 68 mm, NA = 0.44; focus: 8.1 mm length; O/ = 1.1 mm) in a 1.5 T whole body MRI system. For BBB opening, forty 10 ms-long FUS-pulses were applied at a repetition rate of 1 Hz at 1 MPa. The i.v. administration of the micro bubbles (50 μl SonoVue®) was started simultaneously with FUS exposure. To analyze the BBB opening process, short-term and long-term MRI signal dynamics of the interstitial MR contrast agent Magnevist® and the intravascular CA Vasovist® (Bayer-Schering) were studied. To assess short-term signal dynamics, T1-weighted inversion recovery turbo FLASH images (1s) were repeatedly acquired. Repeated 3D FLASH acquisitions (90 s) were used to assess long-term MRI signal dynamics. The short-term MRI signal enhancements showed comparable time constants for both types of MR contrast agents: 1.1 s (interstitial) vs. 0.8 s (intravascular). This time constant may serve as a time constant of the BBB opening process with the given FUS exposure parameters. For the long-term signal dynamics the intravascular CA (62±10 min) showed a fife times greater time constant as the interstitial contrast agent (12±10 min). This might be explained by the high molecular weight (˜60 kDa) of the intravascular Vasovist due to its reversible binding to blood serum albumin resulting in a prolonged half-life in the blood stream compared to the

  6. Nanoparticle Contrast Agents for Enhanced Microwave Imaging and Thermal Treatment of Breast Cancer

    Science.gov (United States)

    2010-10-01

    Sahakian, J. H. Booske, and S. C. Hagness, “Toward carbon-nanotube-based theranostic agents for microwave detection and treatment of breast cancer ... theranostic agents for microwave detection and treatment of breast cancer : Enhanced dielectric and heating response of tissue-mimicking materials...NO. 8, AUGUST 2010 1831 Toward Carbon-Nanotube-Based Theranostic Agents for Microwave Detection and Treatment of Breast Cancer : Enhanced Dielectric

  7. Dosimetry in intravascular brachytherapy

    International Nuclear Information System (INIS)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing 32 P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  8. Immediate Allergic Reactions to Gadolinium-based Contrast Agents: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Behzadi, Ashkan Heshmatzadeh; Zhao, Yize; Farooq, Zerwa; Prince, Martin R

    2018-02-01

    Purpose To perform a systematic review and meta-analysis to determine if there are differences in rates of immediate allergic events between classes of gadolinium-based contrast agents (GBCAs). Materials and Methods PubMed and Google Scholar databases were searched for studies in which rates of immediate adverse events to GBCAs were reported. The American College of Radiology classification system was used to characterize allergic-like events as mild, moderate, or severe, and the total number of administrations of each GBCA was recorded. Where necessary, authors of studies were contacted to clarify data and eliminate physiologic reactions. Relative risks of GBCA types were estimated by using the Mantel-Haenszel type method. Results Nine studies in which immediate reactions to GBCA were recorded from a total of 716 978 administrations of GBCA met the criteria for inclusion and exclusion. The overall and severe rates of GBCA allergic-like adverse events were 9.2 and 0.52 per 10 000 administrations, respectively: 81% (539 of 662) were mild, 13% (86 of 662) were moderate, and 6% (37 of 662) were severe reactions. The nonionic linear chelate gadodiamide had the lowest rate of reactions, at 1.5 (95% confidence interval [CI]: 0.74, 2.4) per 10 000 administrations, which was significantly less than that of linear ionic GBCAs at 8.3 (95% CI: 7.5, 9.2) per 10 000 administrations (relative risk, 0.19 [95% CI: 0.099, 0.36]; P < .00001) and less than that for nonionic macrocyclic GBCAs at 16 (95% CI: 14, 19) per 10 000 administrations (relative risk, 0.12 [95% CI: 0.05, 0.31]; P < .001). GBCAs known to be associated with protein binding had a higher rate of reactions, at 17 (95% CI: 15, 20) per 10 000 administrations compared with the same chelate classification without protein binding, at 5.2 (95% CI: 4.5, 6.0) per 10 000 administrations (relative risk, 3.1 [95% CI: 2.4, 3.8]; P < .0001). Conclusion These data show the lowest rate of immediate allergic adverse events with use

  9. Effect of contrast agent administration on consequences of dosimetry and biology in radiotherapy planning

    Energy Technology Data Exchange (ETDEWEB)

    Lo, Ching-Jung [Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, 259 Wen-Hua 1st Road, Kwei-Shan, Tao-Yuan 333 Taiwan (China); Department of Radiation Oncology, Chang Gung Memorial Hospital, Kwei-Shan, Tao-Yuan 333 Taiwan (China); Yang, Pei-Ying [Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, 259 Wen-Hua 1st Road, Kwei-Shan, Tao-Yuan 333 Taiwan (China); Chao, Tsi-Chian, E-mail: chaot@mail.cgu.edu.tw [Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, 259 Wen-Hua 1st Road, Kwei-Shan, Tao-Yuan 333 Taiwan (China); Tu, Shu-Ju, E-mail: sjtu@mail.cgu.edu.tw [Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, 259 Wen-Hua 1st Road, Kwei-Shan, Tao-Yuan 333 Taiwan (China)

    2015-06-01

    In the treatment planning of radiation therapy, patients may be administrated with contrast media in CT scanning to assist physicians for accurate delineation of the target or organs. However, contrast media are not used in patients during the treatment delivery. In particular, contrast media contain materials with high atomic numbers and dosimetric variations may occur between scenarios where contrast media are present in treatment planning and absent in treatment delivery. In this study we evaluate the effect of contrast media on the dosimetry and biological consequence. An analytical phantom based on AAPM TG 119 and five sets of CT images from clinical patients are included. Different techniques of treatment planning are considered, including 1-field AP, 2-field AP+PA, 4-field box, 7-field IMRT, and RapidArc. RapidArc is a recent technique of volumetric modulated arc therapy and is used in our study of contrast media in clinical scenarios. The effect of RapidArc on dosimetry and biological consequence for administration of contrast media in radiotherapy is not discussed previously in literature. It is shown that dose difference is reduced as the number of external beams is increased, suggesting RapidArc may be favored to be used in the treatment planning enhanced by contrast media. Linear trend lines are fitted for assessment of percent dose differences in the planning target volume versus concentrations of contrast media between plans where contrast media are present and absent, respectively.

  10. Successful transfemoral aortic Edwards(®) SAPIEN(®) bioprosthesis implantation without using iodinated contrast media in a woman with severe allergy to contrast agent.

    Science.gov (United States)

    Leroux, Lionel; Dijos, Marina; Dos Santos, Pierre

    2013-12-01

    Severe anaphylactoid reaction after the use of iodinated contrast media are rare but can contraindicate the use of contrast agent. It was the case of a 53-year-old woman suffering from symptomatic severe aortic stenosis, recused for cardiac surgery because of deleterious effects of chest-wall irradiation, with porcelain aorta. We decided to implant a 23-mm Edwards(®) SAPIEN(®) transcatheter aortic valve via a femoral route without using any contrast media. The implantation was successful after surgical approach of the femoral artery, transesophageal echocardiography guiding, and localization of native leaflets and coronary trunk with catheters. Immediate and one month post-interventional follow-up was favorable and echocardiography showed a good functioning of the aortic bioprosthesis. Although conventional angiography is the best way to visualize the good positioning of the valve before deployment, our case suggests that, in special situations, transfemoral implantation of an Edwards(®) SAPIEN(®) aortic bioprosthesis is feasible without any contrast injection. Copyright © 2012 Wiley Periodicals, Inc.

  11. In Vivo 3T Magnetic Resonance Imaging Using a Biologically Specific Contrast Agent for Prostate Cancer: A Nude Mouse Model

    Directory of Open Access Journals (Sweden)

    Christopher Brian Abraham

    2017-01-01

    Full Text Available We characterized in vivo a functional superparamagnetic iron-oxide magnetic resonance contrast agent that shortens the T2 relaxation time in magnetic resonance imaging (MRI of prostate cancer xenografts. The agent was developed by conjugating Molday ION™ carboxyl-6 (MIC6, with a deimmunized mouse monoclonal antibody (muJ591 targeting prostate-specific membrane antigen (PSMA. This functional contrast agent could be used as a noninvasive method to detect prostate cancer cells that are PSMA positive and more readily differentiate them from surrounding tissues for treatment. The functional contrast agent was injected intravenously into mice and its effect was compared to both MIC6 (without conjugated antibody and phosphate-buffered saline (PBS injection controls. MR imaging was performed on a clinical 3T MRI scanner using a multiecho spin echo (MESE sequence to obtain T2 relaxation time values. Inductively coupled plasma atomic emission spectroscopy was used to confirm an increase in elemental iron in injected mice tumours relative to controls. Histological examination of H&E stained tissues showed normal morphology of the tissues collected.

  12. Development and optimization of a doxorubicin loaded poly(lactic acid) contrast agent for ultrasound directed drug delivery.

    Science.gov (United States)

    Eisenbrey, J R; Burstein, O Mualem; Kambhampati, R; Forsberg, F; Liu, J-B; Wheatley, M A

    2010-04-02

    An echogenic, intravenous drug delivery platform is proposed in which an encapsulated chemotherapeutic can travel to a desired location and drug delivery can be triggered using external, focused ultrasound at the area of interest. Three methods of loading poly(lactic acid) (PLA) shelled ultrasound contrast agents (UCA) with doxorubicin are presented. Effects on encapsulation efficiency, in vitro enhancement, stability, particle size, morphology and release during UCA rupture are compared by loading method and drug concentration. An agent containing doxorubicin within the shell was selected as an ideal candidate for future hepatocellular carcinoma studies. The agent achieved a maximal drug load of 6.2 mg Dox/g PLA with an encapsulation efficiency of 20.5%, showed a smooth surface morphology and tight size distribution (poly dispersity index=0.309) with a peak size of 1865 nm. Acoustically, the agent provided 19 dB of enhancement in vitro at a dosage of 10 microg/ml, with a half life of over 15 min. In vivo, the agent provided ultrasound enhancement of 13.4+/-1.6 dB within the ascending aorta of New Zealand rabbits at a dose of 0.15 ml/kg. While the drug-incorporated agent is thought to be well suited for future drug delivery experiments, this study has shown that agent properties can be tailored for specific applications based on choice of drug loading method. Copyright 2009 Elsevier B.V. All rights reserved.

  13. High-resolution motion compensated MRA in patients with congenital heart disease using extracellular contrast agent at 3 Tesla

    Directory of Open Access Journals (Sweden)

    Dabir Darius

    2012-10-01

    Full Text Available Abstract Background Using first-pass MRA (FP-MRA spatial resolution is limited by breath-hold duration. In addition, image quality may be hampered by respiratory and cardiac motion artefacts. In order to overcome these limitations an ECG- and navigator-gated high-resolution-MRA sequence (HR-MRA with slow infusion of extracellular contrast agent was implemented at 3 Tesla for the assessment of congenital heart disease and compared to standard first-pass-MRA (FP-MRA. Methods 34 patients (median age: 13 years with congenital heart disease (CHD were prospectively examined on a 3 Tesla system. The CMR-protocol comprised functional imaging, FP- and HR-MRA, and viability imaging. After the acquisition of the FP-MRA sequence using a single dose of extracellular contrast agent the motion compensated HR-MRA sequence with isotropic resolution was acquired while injecting the second single dose, utilizing the timeframe before viability imaging. Qualitative scores for image quality (two independent reviewers as well as quantitative measurements of vessel sharpness and relative contrast were compared using the Wilcoxon signed-rank test. Quantitative measurements of vessel diameters were compared using the Bland-Altman test. Results The mean image quality score revealed significantly better image quality of the HR-MRA sequence compared to the FP-MRA sequence in all vessels of interest (ascending aorta (AA, left pulmonary artery (LPA, left superior pulmonary vein (LSPV, coronary sinus (CS, and coronary ostia (CO; all p  Conclusions An ECG- and navigator-gated HR-MRA-protocol with infusion of extracellular contrast agent at 3 Tesla is feasible. HR-MRA delivers significantly better image quality and vessel sharpness compared to FP-MRA. It may be integrated into a standard CMR-protocol for patients with CHD without the need for additional contrast agent injection and without any additional examination time.

  14. Development of Gd(III) porphyrin-conjugated chitosan nanoparticles as contrast agents for magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jahanbin, Tania [Université Paul Sabatier, Toulouse III, INSERM U825, CHU Purpan, 31059 Toulouse Cedex 9 (France); Sauriat-Dorizon, Hélène [Institut de Chimie Moléculaire et des Matériaux d' Orsay, UMR CNRS 8182, ECBB, Université Paris-Sud, 91405 Orsay (France); Spearman, Peter [Faculty of Science, Engineering and Computing, University of Kingston, Penrhyn Road Kingston upon Thames Surrey KT1 2EE, London (United Kingdom); Benderbous, Soraya, E-mail: soraya.benderbous@univ-tlse3.fr [Université Paul Sabatier, Toulouse III, INSERM U825, CHU Purpan, 31059 Toulouse Cedex 9 (France); Korri-Youssoufi, Hafsa, E-mail: hafsa.korri-youssoufi@u-psud.fr [Institut de Chimie Moléculaire et des Matériaux d' Orsay, UMR CNRS 8182, ECBB, Université Paris-Sud, 91405 Orsay (France)

    2015-07-01

    A novel magnetic resonance imaging (MRI) contrast agent based on gadolinium meso-tetrakis(4-pyridyl)porphyrin [Gd(TPyP)] conjugated with chitosan nanoparticles has been developed. The chitosan nanoparticles were synthesized following an ionic gelation method and the conditions optimized to generate small nanoparticles (CNs) with a narrow size distribution of 35–65 nm. The gadolinium meso-tetrakis(4-pyridyl)porphyrin [Gd(TPyP)] was loaded into chitosan nanoparticles by passive adsorption. The interaction of chitosan with Gd(TPyP) has been examined by UV–visible, Fourier transform infrared spectroscopies (FT-IR) and inductively coupled plasma mass spectrometry (ICP-MS), which indicate the successful association of Gd(TPyP) without any structural distortion throughout the chitosan nanoparticles. The potential of Gd(TPyP)-CNs as MRI contrast agent has been investigated by magnetic resonance imaging (MRI) in-vitro. Relaxivities of Gd(TPyP)-CNs obtained from T{sub 1}-weighted images, increased with Gd concentration and attained an optimum r{sub 1} of 38.35 mM{sup −1} s{sup −1}, which is 12-fold higher compared to commercial Gd-DOTA (~ 4 mM{sup −1} s{sup −1} at 3T). The combination of such strong MRI contrast with the known properties of porphyrins in photodynamic therapy and biocompatibility of chitosan, presents a new perspective in using these compounds in cancer theranostics. - Highlights: • Synthesis of chitosan nanoparticles with small size • Study of loading properties with gadolinium porphyrins • In vitro properties of the conjugated complex as contrast agent for MRI imaging • Comparison of MRI properties with commercial contrast agent Gd-DOTA.

  15. Pretest Score for Predicting Microbubble Contrast Agent Use in Stress Echocardiography: A Method to Increase Efficiency in the Echo Laboratory

    Directory of Open Access Journals (Sweden)

    Mathieu Bernier

    2009-01-01

    contrast. Logistic regression models were used to evaluate the association between individual characteristics and contrast use. An 11-point score was derived from the significant characteristics. Results. Variables associated with microbubble use were age, sex, smoking, presence of multiple risk factors, bodymass index (BMI, referral for dobutamine stress echocardiography, history of coronary artery disease, and abnormal baseline electrocardiogram. All variables except BMI were given a score of 1 if present and 0 if absent; BMI was given a score of 0 to 4 according to its value. An increased score was directly proportional to increased likelihood of contrast use. The score cutoff value to optimize sensitivity and specificity was 5. Conclusions. A pretest score can be computed from information available before imaging. It may facilitate contrast agent use through early identification of patients who are likely to benefit from improved endocardial border definition.

  16. Intravascular blood coagulation after irradiation

    International Nuclear Information System (INIS)

    Sushkevich, G.N.

    1981-01-01

    The problems of activation of intravascular blood coagulation (JVBC) at different stages after irradiation, are considered. JVBC peculiarities (disseminated intravascular syndrome (DIV) or thrombo hemorrhagic syndrome) are investigated. Literature on alterations which take place in the organism under effect of ionizing irradiation is analyzed. This analysis proves the characteristic features of thrombinogenesis activation and development of DIV syndrome not only in the early post-radiation period, but in the middle of radiation disease, as well. It is also shown that ionizing radiation activizes the hemocoagulation process and causes IVBC in the case of both local and general irradiation [ru

  17. Activation of platelets by low-osmolar contrast media: differential effects of ionic and nonionic agents

    NARCIS (Netherlands)

    Hardeman, M. R.; Konijnenberg, A.; Sturk, A.; Reekers, J. A.

    1994-01-01

    To determine the effects of an ionic low-osmolar contrast medium (ioxaglate) and two nonionic low-osmolar contrast media (iohexol and iopamidol) on human platelet activation in vitro. Flow cytometry analysis subsequent to reaction with fluorescence-labeled monoclonal antibodies was used to detect

  18. Bioadhesive agents in addition to oral contrast media - evaluation in an animal model

    International Nuclear Information System (INIS)

    Conrad, R.; Schneider, G.; Textor, J.; Schild, H.H.; Fimmers, R.

    1998-01-01

    Purpose: To evaluate the additional effect of bioadhesives in combination with iotrolan and barium as oral contrast media in an animal model. Method: The bioadhesives Noveon, CMC, Tylose and Carbopol 934 were added to iotrolan and barium. The solutions were administered to rabbits by a feeding tube. The animals were investigated by computed tomography (CT) and radiography after 0,5, 4, 12, 24 and in part after 48 hours. Mucosal coating and contrast filling of the bowel were evaluated. Results: Addition of bioadhesives to oral contrast media effected long-term contrast in the small intestine and colon, but no improvement in continuous filling and coating of the gastrointestinal tract was detected. Mucosal coating was seen only in short regions of the caecum and small intestine. In CT the best results for coating were observed with tylose and CMC, in radiography additionally with carbopol and noveon. All contrast medium solutions were well tolerated. Conclusion: The evaluated contrast medium solutions with bioadhesives have shown long-term contrast but no improvement in coating in comparison to conventional oral contrast media. (orig.) [de

  19. Voiding Urosonography with Second-Generation Ultrasound Contrast Agent for Diagnosis of Vesicoureteric Reflux: First Local Pilot Study.

    Science.gov (United States)

    Kuzmanovska, Dafina; Risteski, Aleksandar; Kambovska, Margarita; Trpcevski, Tase; Sahpazova, Emilija; Petrovski, Mile

    2017-04-15

    Vesicoureteric reflux (VUR) is an important association of paediatric urinary tract infection (UTI) found in 30-50% of all children presenting with first UTI. Contrast-enhanced voiding ultrasonography (ceVUS) has become an important radiation-free method for VUR detection in children. Its sensitivity in detecting VUR has greatly improved due to the development of the contrast-specific ultrasound techniques and the introduction of the second-generation ultrasound contrast agent, superseding the diagnostic accuracy of standard radiological procedures. This article aimed to summarise the current literature and discuss the first local pilot study performed in our institution on detection of vesicoureteric reflux by contrast-enhanced voiding ultrasonography with second- generation agent (SonoVue, Bracco, Italy). Retrospective review of the first 31 ceVUS (24 girls, 7 boys) was presented. Age range was 2 months to 18 years (mean = 6.4 ± 4.9). All examinations were well tolerated without any adverse incident. VUR was shown in 20 (64.5%) children in 32/62 (51.6) nephroureteral units (NUUs). In 18 NUUs, VUR was grade II/V, in 11 Grade III/V and in 3 grade IV/V, respectively. Urethra was shown in 19/31 children and in all boys, without pathological finding. In two girls spinning top urethra has been detected. Subsequent urodynamic studies revealed functional bladder problem in both. Contrast-enhanced voiding urosonography using intravesical second generation ultrasound contrast agent could be recommend as a valid alternative diagnostic modality for detecting vesicoureteral reflux and evaluation of the distal urinary tract in children, based on its radiation-free, highly efficacious, reliable, and safe characteristics.

  20. Optimization of multi-pulse sequences for nonlinear contrast agent imaging using a cMUT array

    Science.gov (United States)

    Novell, Anthony; Arena, Christopher B.; Kasoji, Sandeep; Dayton, Paul A.

    2015-04-01

    Capacitive micromachined ultrasonic transducer (cMUT) technology provides advantages such as wide frequency bandwidth, which can be exploited for contrast agent imaging. Nevertheless, the efficiency of traditional multi-pulse imaging schemes, such as pulse inversion (PI), remains limited because of the intrinsic nonlinear character of cMUTs. Recently, a new contrast imaging sequence, called bias voltage modulation sequence (BVM), has been specifically developed for cMUTs to suppress their unwanted nonlinear behavior. In this study, we propose to optimize contrast agent detection by combining the BVM sequence with PI and/or chirp reversal (CR). An aqueous dispersion of lipid encapsulated microbubbles was exposed to several combinations of multi-pulse imaging sequences. Approaches were evaluated in vitro using 9 inter-connected elements of a cMUT linear array (excitation frequency of 4 MHz peak negative pressure of 100 kPa). For sequences using chirp excitations, a specific compression filter was designed to compress and extract several nonlinear components from the received microbubble responses. A satisfactory cancellation of the nonlinear signal from the source is achieved when BVM is combined with PI and CR. In comparison with PI and CR imaging modes alone, using sequences incorporating BVM increases the contrast-to-tissue ratio by 10.0 dB and 4.6 dB, respectively. Furthermore, the combination of BVM with CR and PI results in a significant increase of the contrast-to-noise ratio (+29 dB). This enhancement is attributed to the use of chirps as excitation signals and the improved preservation of several nonlinear components contained within the contrast agent response.

  1. Optimization of multi-pulse sequences for nonlinear contrast agent imaging using a cMUT array

    International Nuclear Information System (INIS)

    Novell, Anthony; Arena, Christopher B; Kasoji, Sandeep; Dayton, Paul A

    2015-01-01

    Capacitive micromachined ultrasonic transducer (cMUT) technology provides advantages such as wide frequency bandwidth, which can be exploited for contrast agent imaging. Nevertheless, the efficiency of traditional multi-pulse imaging schemes, such as pulse inversion (PI), remains limited because of the intrinsic nonlinear character of cMUTs. Recently, a new contrast imaging sequence, called bias voltage modulation sequence (BVM), has been specifically developed for cMUTs to suppress their unwanted nonlinear behavior. In this study, we propose to optimize contrast agent detection by combining the BVM sequence with PI and/or chirp reversal (CR). An aqueous dispersion of lipid encapsulated microbubbles was exposed to several combinations of multi-pulse imaging sequences. Approaches were evaluated in vitro using 9 inter-connected elements of a cMUT linear array (excitation frequency of 4 MHz; peak negative pressure of 100 kPa). For sequences using chirp excitations, a specific compression filter was designed to compress and extract several nonlinear components from the received microbubble responses. A satisfactory cancellation of the nonlinear signal from the source is achieved when BVM is combined with PI and CR. In comparison with PI and CR imaging modes alone, using sequences incorporating BVM increases the contrast-to-tissue ratio by 10.0 dB and 4.6 dB, respectively. Furthermore, the combination of BVM with CR and PI results in a significant increase of the contrast-to-noise ratio (+29 dB). This enhancement is attributed to the use of chirps as excitation signals and the improved preservation of several nonlinear components contained within the contrast agent response. (paper)

  2. In Vitro Acoustic Characterization of Three Phospholipid Ultrasound Contrast Agents from 12 to 43 MHz

    Science.gov (United States)

    Sun, Chao; Sboros, Vassilis; Butler, Mairead B.; Moran, Carmel M.

    2014-01-01

    The acoustic properties of two clinical (Definity, Lantheus Medical Imaging, North Billerica, MA, USA; SonoVue, Bracco S.P.A., Milan, Italy) and one pre-clinical (MicroMarker, untargeted, Bracco, Geneva, Switzerland; VisualSonics, Toronto, ON, Canada) ultrasound contrast agent were characterized using a broadband substitution technique over the ultrasound frequency range 12–43 MHz at 20 ± 1°C. At the same number concentration, the acoustic attenuation and contrast-to-tissue ratio of the three native ultrasound contrast agents are comparable at frequencies below 30 MHz, though their size distributions and encapsulated gases and shells differ. At frequencies above 30 MHz, native MicroMarker has higher attenuation values and contrast-to-tissue ratios than native Definity and SonoVue. Decantation was found to be an effective method to alter the size distribution and concentration of native clinical microbubble populations, enabling further contrast enhancement for specific pre-clinical applications. PMID:24361219

  3. Synthesis, structural characterization and in vitro testing of dysprosium containing silica particles as potential MRI contrast enhancing agents

    Energy Technology Data Exchange (ETDEWEB)

    Chiriac, L.B.; Trandafir, D.L. [Faculty of Physics & National Magnetic Resonance Center, Babeş-Bolyai University, Cluj-Napoca, RO-400084 (Romania); Interdisciplinary Research Institute on Bio-Nano-Sciences & Faculty of Physics, Babeş-Bolyai University, Cluj-Napoca, RO-400084 (Romania); Turcu, R.V.F. [Faculty of Physics & National Magnetic Resonance Center, Babeş-Bolyai University, Cluj-Napoca, RO-400084 (Romania); Todea, M. [Interdisciplinary Research Institute on Bio-Nano-Sciences & Faculty of Physics, Babeş-Bolyai University, Cluj-Napoca, RO-400084 (Romania); Simon, S., E-mail: simons@phys.ubbcluj.ro [Faculty of Physics & National Magnetic Resonance Center, Babeş-Bolyai University, Cluj-Napoca, RO-400084 (Romania); Interdisciplinary Research Institute on Bio-Nano-Sciences & Faculty of Physics, Babeş-Bolyai University, Cluj-Napoca, RO-400084 (Romania)

    2016-11-01

    Highlights: • Dysprosium containing silica microparticles obtained by freeze and spray drying. • Higher structural units interconnection achieved in freeze vs. spray dried samples. • Dy occurance on the outermost layer of the microparticles evidenced by XPS. • Enhanced MRI contrast observed for freeze dried samples with 5% mol Dy{sub 2}O{sub 3}. - Abstract: The work is focused on synthesis and structural characterization of novel dysprosium-doped silica particles which could be considered as MRI contrast agents. Sol-gel derived silica rich particles obtained via freeze-drying and spray-drying processing methods were structurally characterized by XRD, {sup 29}Si MAS-NMR and XPS methods. The occurrence of dysprosium on the outermost layer of dysprosium containing silica particles was investigated by XPS analysis. The MRI contrast agent characteristics have been tested using RARE-T{sub 1} and RARE-T{sub 2} protocols. The contrast of MRI images delivered by the investigated samples was correlated with their local structure. Dysprosium disposal on microparticles with surface structure characterised by decreased connectivity of the silicate network units favours dark T{sub 2}-weighted MRI contrast properties.

  4. Blunt abdominal trauma: does the use of a second-generation sonographic contrast agent help to detect solid organ injuries?

    Science.gov (United States)

    Poletti, Pierre-Alexandre; Platon, Alexandra; Becker, Christoph D; Mentha, Gilles; Vermeulen, Bernard; Buhler, Léo H; Terrier, François

    2004-11-01

    The objective of our study was to prospectively evaluate whether a second-generation sonography contrast agent (SonoVue) can improve the conspicuity of solid organ injuries (liver; spleen; or kidney, including adrenal glands) in patients with blunt abdominal trauma. Two hundred ten consecutive hemodynamically stable trauma patients underwent both abdominal sonography and CT at admission. The presence of solid organ injuries and the quality of sonography examinations were recorded. Patients with false-negative sonography findings for solid organ injuries in comparison with CT results underwent control sonography. If a solid organ injury was still undetectable, contrast-enhanced sonography was performed. Findings of admission, control, and contrast-enhanced sonograms were compared with CT results for their ability to depict solid organ injuries. Contrast-enhanced sonography was also performed in patients in whom a vascular injury (pseudoaneurysm) was shown on admission or control CT. CT findings were positive for 88 solid organ injuries in 71 (34%) of the 210 patients. Admission, control, and contrast-enhanced sonograms had a detection rate for solid organ injury of 40% (35/88), 57% (50/88), and 80% (70/88), respectively. The improvement in the detection rate between control and contrast-enhanced sonography was statistically significant (p = 0.001). After exclusion of low-quality examinations, contrast-enhanced sonography still missed 18% of solid organ injuries. Five vascular liver (n = 1) and spleen (n = 4) injuries (pseudoaneurysms) were detected on CT; all were visible on contrast-enhanced sonography. Contrast-enhanced sonography misses a large percentage of solid organ injuries and cannot be recommended to replace CT in the triage of hemodynamically stable trauma patients. However, contrast-enhanced sonography could play a role in the detection of pseudoaneurysms.

  5. Potential dependent superiority of gold nanoparticles in comparison to iodinated contrast agents

    International Nuclear Information System (INIS)

    Jackson, Price A.; Rahman, Wan Nordiana W. Abd.; Wong, Christopher J.; Ackerly, Trevor; Geso, Moshi

    2010-01-01

    Purpose: To identify the benefits in image contrast enhancement using gold nanoparticles (AuNPs) compared to conventional iodinated contrast media. Materials and methods: Gold nanoparticles and iodinated contrast media were evaluated for contrast enhancement at various X-ray tube potentials in an imaging phantom. Iopromide and AuNP suspension were equalized according to molar concentration of radiopaque element (0.5077 Mol/L). Contrast-to-noise ratio is used to quantify contrast enhancement. Both projectional radiographic (40-80 kVp) and computed tomography (CT) (80-140kVp) imaging modalities were examined. Results and conclusions: Findings indicate 89% improvement in CNR at low energies near the mammographic range (40 kVp). However, as expected no significant difference in enhancement was observed at potentials commonly used for angiography (around 80 kVp) probably due to the k-edge influence for iodine. At the highest energies typically available in computed tomography, significant improvement in contrast enhancement using gold nanoparticles is obtained, 114% greater CNR than that produced by iodine at 140 kVp. Experimental findings for 70-120 kVp spectra correlate well with the theoretical calculations based on linear attenuation coefficients. Superior attenuation of gold nanoparticles at low and high kVp potentials support their further (pre)clinical evaluation.

  6. Noninvasive Ambient Pressure Estimation using Ultrasound Contrast Agents -- Invoking Subharmonics for Cardiac and Hepatic Applications

    Science.gov (United States)

    Dave, Jaydev K.

    Ultrasound contrast agents (UCAs) are encapsulated microbubbles that provide a source for acoustic impedance mismatch with the blood, due to difference in compressibility between the gas contained within these microbubbles and the blood. When insonified by an ultrasound beam, these UCAs act as nonlinear scatterers and enhance the echoes of the incident pulse, resulting in scattering of the incident ultrasound beam and emission of fundamental (f0), subharmonic (f0/2), harmonic (n*f0; n ∈ N) and ultraharmonic (((2n-1)/2)*f0; n ∈ N & n > 1) components in the echo response. A promising approach to monitor in vivo pressures revolves around the fact that the ultrasound transmit and receive parameters can be selected to induce an ambient pressure amplitude dependent subharmonic signal. This subharmonic signal may be used to estimate ambient pressure amplitude; such technique of estimating ambient pressure amplitude is referred to as subharmonic aided pressure estimation or SHAPE. This project develops and evaluates the feasibility of SHAPE to noninvasively monitor cardiac and hepatic pressures (using commercially available ultrasound scanners and UCAs) because invasive catheter based pressure measurements are used currently for these applications. Invasive catheter based pressure measurements pose risk of introducing infection while the catheter is guided towards the region of interest in the body through a percutaneous incision, pose risk of death due to structural or mechanical failure of the catheter (which has also triggered product recalls by the USA Food and Drug Administration) and may potentially modulate the pressures that are being measured. Also, catheterization procedures require fluoroscopic guidance to advance the catheter to the site of pressure measurements and such catheterization procedures are not performed in all clinical centers. Thus, a noninvasive technique to obtain ambient pressure values without the catheterization process is clinically

  7. Adverse allergic reactions to linear ionic gadolinium-based contrast agents: experience with 194, 400 injections

    International Nuclear Information System (INIS)

    Aran, S.; Shaqdan, K.W.; Abujudeh, H.H.

    2015-01-01

    Aim: To report the authors' experience with the administration of four gadolinium-based contrast agents (GBCA; gadopentetate dimeglumine, gadofosveset trisodium, gadoxetate disodium and gadobenate dimeglumine) in a large study population at a single, large academic medical centre. Materials and methods: The institutional review board approved this retrospective study in which data in the electronic incident reporting system were searched. A total of 194, 400 intravenous administrations of linear ionic GBCAs were assessed for the incidence of adverse reactions and risk factors from 1 January 2007 to 14 January 2014. The severity of reactions (mild, moderate, and severe), patient type (outpatients, inpatients, and emergency), examination type, and treatment options were also investigated. Results: In total, 204/194400 (0.1%) patients (mean age 45.7 ± 14.9) showed adverse reactions, consisting of 6/746 (0.80%), 10/3200 (0.31%), 14/6236 (0.22%) and 174/184218 (0.09%), for gadofosveset trisodium, gadoxetate disodium, gadobenate dimeglumine, and gadopentetate dimeglumine, respectively. An overall significant difference was found between different GBCAs regarding the total number of reactions (p < 0.0001). When comparing the GBCAs together, significant differences were found between gadofosveset trisodium versus gadopentetate dimeglumine (p < 0.0001), gadofosveset trisodium versus gadobenate dimeglumine (p = 0.0051), gadoxetate disodium versus gadopentetate dimeglumine (p < 0.0001) and gadopentetate dimeglumine versus gadobenate dimeglumine (p = 0.0013). Rate of reaction was higher in females (F: 146/113187, 0.13%/M: 58/81213, 0.07%; p < 0.0001). Rate of reactions was higher in outpatient (180/158885, 0.11%), emergency (10/10413, 0.10%), and inpatients (14/25102, 0.05%), respectively (p < 0.0001). Most of the patients had mild symptoms 171/204 (83.8%). Abdomen–pelvis, liver, and thoracic examinations had highest rates of reactions (0.17 versus 0

  8. Improved tumor-targeting MRI contrast agents: Gd(DOTA) conjugates of a cycloalkane-based RGD peptide

    International Nuclear Information System (INIS)

    Park, Ji-Ae; Lee, Yong Jin; Ko, In Ok; Kim, Tae-Jeong; Chang, Yongmin; Lim, Sang Moo; Kim, Kyeong Min; Kim, Jung Young

    2014-01-01

    Highlights: • Development of improved tumor-targeting MRI contrast agents. • To increase the targeting ability of RGD, we developed cycloalkane-based RGD peptides. • Gd(DOTA) conjugates of cycloalkane-based RGD peptide show improved tumor signal enhancement in vivo MR images. - Abstract: Two new MRI contrast agents, Gd-DOTA-c(RGD-ACP-K) (1) and Gd-DOTA-c(RGD-ACH-K) (2), which were designed by incorporating aminocyclopentane (ACP)- or aminocyclohexane (ACH)-carboxylic acid into Gd-DOTA (gadolinium-tetraazacyclo dodecanetetraacetic acid) and cyclic RGDK peptides, were synthesized and evaluated for tumor-targeting ability in vitro and in vivo. Binding affinity studies showed that both 1 and 2 exhibited higher affinity for integrin receptors than cyclic RGDyK peptides, which were used as a reference. These complexes showed high relaxivity and good stability in human serum and have the potential to improve target-specific signal enhancement in vivo MR images

  9. Improved tumor-targeting MRI contrast agents: Gd(DOTA) conjugates of a cycloalkane-based RGD peptide

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji-Ae, E-mail: jpark@kirams.re.kr [Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Lee, Yong Jin; Ko, In Ok [Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Kim, Tae-Jeong; Chang, Yongmin [Institute of Biomedical Engineering, Kyungpook National University, Daegu (Korea, Republic of); Lim, Sang Moo [Department of Nuclear Medicine, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Kim, Kyeong Min [Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Kim, Jung Young, E-mail: jykim@kirams.re.kr [Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2014-12-12

    Highlights: • Development of improved tumor-targeting MRI contrast agents. • To increase the targeting ability of RGD, we developed cycloalkane-based RGD peptides. • Gd(DOTA) conjugates of cycloalkane-based RGD peptide show improved tumor signal enhancement in vivo MR images. - Abstract: Two new MRI contrast agents, Gd-DOTA-c(RGD-ACP-K) (1) and Gd-DOTA-c(RGD-ACH-K) (2), which were designed by incorporating aminocyclopentane (ACP)- or aminocyclohexane (ACH)-carboxylic acid into Gd-DOTA (gadolinium-tetraazacyclo dodecanetetraacetic acid) and cyclic RGDK peptides, were synthesized and evaluated for tumor-targeting ability in vitro and in vivo. Binding affinity studies showed that both 1 and 2 exhibited higher affinity for integrin receptors than cyclic RGDyK peptides, which were used as a reference. These complexes showed high relaxivity and good stability in human serum and have the potential to improve target-specific signal enhancement in vivo MR images.

  10. ParaCEST Agents Encapsulated in Reverse Nano-Assembled Capsules (RACs: How Slow Molecular Tumbling Can Quench CEST Contrast

    Directory of Open Access Journals (Sweden)

    Annah Farashishiko

    2018-04-01

    Full Text Available Although paraCEST is a method with immense scope for generating image contrast in MRI, it suffers from the serious drawback of high detection limits. For a typical discrete paraCEST agent the detection limit is roughly an order of magnitude higher than that of a clinically used relaxation agent. One solution to this problem may be the incorporation of a large payload of paraCEST agents into a single macromolecular agent. Here we report a new synthetic method for accomplishing this goal: incorporating a large payload of the paraCEST agent DyDOTAM3+ into a Reverse Assembled nano-Capsule. An aggregate can be generated between this chelate and polyacrylic acid (PAA after the addition of ethylene diamine. Subsequent addition of polyallylamine hydrochloride (PAH followed by silica nanoparticles generated a robust encapsulating shell and afforded capsule with a mean hydrodynamic diameter of 650 ± 250 nm. Unfortunately this encapsulation did not have the effect of amplifying the CEST effect per agent, but quenched the CEST altogether. The quenching effect of encapsulation could be attributed to the effect of slowing molecular tumbling, which is inevitable when the chelate is incorporated into a nano-scale material. This increases the transverse relaxation rate of chelate protons and a theoretical examination using Solomon Bloembergen Morgan theory and the Bloch equations shows that the increase in the transverse relaxation rate constant for the amide protons, in even modestly sized nano-materials, is sufficient to significantly quench CEST.

  11. Retrospective analysis of patients for development of nephrogenic systemic fibrosis following conventional angiography using gadolinium-based contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Hoppe, Hanno; Spagnuolo, Sara; Froehlich, Johannes M.; Thoeny, Harriet C. [University Hospital Bern, Institute of Diagnostic, Interventional, and Pediatric Radiology, Inselspital, Bern (Switzerland); Nievergelt, Helga [University Hospital Bern, Clinic of Dermatology, Bern (Switzerland); Dinkel, Hans-Peter [Hospital Landshut, Institute of Diagnostic and Interventional Radiology, Landshut (Germany); Gretener, Silvia [University Hospital of Bern, Division of Vascular Medicine, Swiss Cardiovascular Center, Bern (Switzerland)

    2010-03-15

    The purpose was to retrospectively review the data of 27 patients with renal insufficiency who underwent conventional angiography with gadolinium-based contrast agents (GDBCA) as alternative contrast agents and assess the occurrence of nephrogenic systemic fibrosis (NSF) together with associated potential risk factors. This HIPAA-compliant study had institutional review board approval, and informed consent was waived. Statistical analysis was performed for all available laboratory and clinical data, including dermatology reports. Type and amount of the GDBCA used were recorded for angiography and additional MRI studies, if applicable. Serum creatinine levels (SCr) pre- and post-angiography were recorded, and estimated glomerular filtration rates (eGFR) were calculated. Ten female and 17 male patients who underwent angiography with GDBCA were included. The mean amount of GDBCA administered was 44 {+-} 15.5 ml (range 15-60 ml) or 0.24 + 0.12 mmol/kg (range 0.1-0.53 mmol/kg). At the time of angiography all patients had renal insufficiency (eGFR <60 ml/min/1.73 m{sup 2}). Mean eGFR pre-angiography was 26 ml/min/1.73 m{sup 2} and 33 ml/min/1.73 m{sup 2} post-angiography. The mean follow-up period covers 28 months, range 1-84 months. Additional MRI studies with GDBCA administration were performed in 15 patients. One patient with typical skin lesions had developed biopsy-confirmed NSF. Conventional arterial angiography with GDBCA may play a role in the development of NSF in patients with renal insufficiency. Alternative contrast agents, such as CO{sub 2} angiography or rather the use of low doses of iodinated contrast agents, should be considered in these patients. (orig.)

  12. Searching for an alternative oral contrast agent for GI tract MR imaging; in vitro phase, initial report

    International Nuclear Information System (INIS)

    Okla, W.; Szeszkowski, W.; Cieszanowski, A.; Golebiowski, M.

    2002-01-01

    MR has been recently considered to be suitable method for detection GI tract pathologies. A few substances (some of a natural origin) seem to act as an efficient oral MR contrast agents. The aim of this study is to find an alternative substance, which can be administrated orally to patients in order to enhance signal intensity (SI). The ideal agent should have a biphase pattern (high SI in T1 and low in T2), and should be nontoxic and cost effective. Phantom experiments were conducted with 1.5 T MR scanner. T1W and T2W sequences were used for initial estimation. Number of different agents such as: water, Gd-DTPA, barium sulfate, green tea, blueberry juice, cranberry juice, blackcurrant juice, and some more were evaluated. Signal intensity was measured by using elliptical region of interest (ROI). MR imaging in one patient with stomach cancer was also performed. In T1W-FFE sequence cranberry juice reached satisfactorily high signal (SI=1760.14). In T2W-TSE sequence this substance reduced signal intensity (SI=23.10) almost to background level. Blueberry juice appear to be the next substance capable to generate high signal (SI=1558.31) in T1W sequence (T1-TSE). MR examination of a patient with stomach adenocarcinoma (using blueberry juice as an oral contrast agent) satisfactorily depicted and delineated tumor mass on both: T1W and T2W images. Cranberry juice and blueberry juice seemed to act effectively as oral contrast agents for gastrointestinal MR imaging. Thus they need further exploration and trials. (author)

  13. Therapeutic response assessment of percutaneous radiofrequency ablation for hepatocellular carcinoma: Utility of contrast-enhanced agent detection imaging

    International Nuclear Information System (INIS)

    Kim, Chan Kyo; Choi, Dongil; Lim, Hyo K.; Kim, Seung Hoon; Lee, Won Jae; Kim, Min Ju; Lee, Ji Yeon; Jeon, Yong Hwan; Lee, Jongmee; Lee, Soon Jin; Lim, Jae Hoon

    2005-01-01

    Purpose: To assess the utility of contrast-enhanced agent detection imaging (ADI) in the assessment of the therapeutic response to percutaneous radiofrequency (RF) ablation in patients with hepatocellular carcinoma (HCC). Materials and methods: Ninety patients with a total of 97 nodular HCCs (mean, 2.1 ± 1.3 cm; range, 1.0-5.0 cm) treated with percutaneous RF ablation under the ultrasound guidance were evaluated with contrast-enhanced ADI after receiving an intravenous bolus injection of a microbubble contrast agent (SH U 508A). We obtained serial contrast-enhanced ADI images during the time period from 15 to 90 s after the initiation of the bolus contrast injection. All of the patients underwent a follow-up four-phase helical CT at 1 month after RF ablation, which was then repeated at 2-4 month intervals during a period of at least 12 months. The results of the contrast-enhanced ADI were compared with those of the follow-up CT in terms of the presence or absence of residual unablated tumor and local tumor progression in the treated lesions. Results: On contrast-enhanced ADI, technical success was obtained in 94 (97%) of the 97 HCCs, while residual unablated tumors were found in three HCCs (3%). Two of the three tumors that were suspicious (was not proven) for incomplete ablation were subjected to additional RF ablation. The remaining one enhancing lesion that was suspicious of a residual tumor on contrast-enhanced ADI was revealed to be reactive hyperemia at the 1-month follow-up CT. Therefore; the diagnostic concordance between the contrast-enhanced ADI and 1-month follow-up CT was 99%. Of the 94 ablated HCCs without residual tumors on both the contrast-enhanced ADI and 1-month follow-up CT after the initial RF ablation, five (5%) had CT findings of local tumor progression at a subsequent follow-up CT. Conclusion: Despite its limitations in predicting local tumor progression in the treated tumors, contrast-enhanced ADI is potentially useful for evaluating the

  14. Intravascular Stenting in Microvascular Anastomoses

    DEFF Research Database (Denmark)

    Assersen, Kristine; Sørensen, Jens

    2015-01-01

    Background The effect of intravascular stenting (IVaS) on microvascular anastomoses has given adverse results. For experienced microsurgeons the benefit of IVaS is doubtful. We have investigated the potential benefit of the IVaS technique for two groups of inexperienced microsurgeons with differe...

  15. Intravascular bronchio-alveolar tumor

    International Nuclear Information System (INIS)

    Mata, J.M.; Caceres, J.; Prat, J.; Lopez, J.I.; Velilla, O.

    1991-01-01

    In 1975 Dail and Liebow described the clinical and pathological characteristics of a pulmonary tumor which they dominated intravascular bronchio-alveolar tumor (IVBAT). Our aim is to acquaint radiologists with the existence of this tumor by describing the radiologic findings in 2 patients with IVBAT, 1 with hepatic involvement ant the other with pulmonary osteoarthropathy. (author). 7 refs.; 2 figs

  16. Design, synthesis, and evaluation of VEGFR-targeted macromolecular MRI contrast agent based on biotin-avidin-specific binding.

    Science.gov (United States)

    Liu, Yongjun; Wu, Xiaoyun; Sun, Xiaohe; Wang, Dan; Zhong, Ying; Jiang, Dandan; Wang, Tianqi; Yu, Dexin; Zhang, Na

    2017-01-01

    Developing magnetic resonance imaging (MRI) contrast agents with high relaxivity and specificity was essential to increase MRI diagnostic sensitivity and accuracy. In this study, the MRI contrast agent, vascular endothelial growth factor receptor (VEGFR)-targeted poly (l-lysine) (PLL)-diethylene triamine pentacetate acid (DTPA)-gadolinium (Gd) (VEGFR-targeted PLL-DTPA-Gd, VPDG), was designed and prepared to enhance the MRI diagnosis capacity of tumor. Biotin-PLL-DTPA-Gd was synthesized first, then, VEGFR antibody was linked to biotin-PLL-DTPA-Gd using biotin-avidin reaction. In vitro cytotoxicity study results showed that VPDG had low toxicity to MCF-7 cells and HepG2 cells at experimental concentrations. In cell uptake experiments, VPDG could significantly increase the internalization rates (61.75%±5.22%) in VEGFR-positive HepG2 cells compared to PLL-DTPA-Gd (PDG) (25.16%±4.71%, P <0.05). In MRI studies in vitro, significantly higher T1 relaxivity (14.184 mM -1 s -1 ) was observed compared to Magnevist ® (4.9 mM -1 s -1 ; P <0.01). Furthermore, in vivo MRI study results showed that VPDG could significantly enhance the tumor signal intensity and prolong the diagnostic time (from <1 h to 2.5 h). These results indicated that macromolecular VPDG was a promising MRI contrast agent and held great potential for molecular diagnosis of tumor.

  17. Curcumin Targeted, Polymalic Acid-Based MRI Contrast Agent for the Detection of Aβ Plaques in Alzheimer's Disease.

    Science.gov (United States)

    Patil, Rameshwar; Gangalum, Pallavi R; Wagner, Shawn; Portilla-Arias, Jose; Ding, Hui; Rekechenetskiy, Arthur; Konda, Bindu; Inoue, Satoshi; Black, Keith L; Ljubimova, Julia Y; Holler, Eggehard

    2015-09-01

    Currently, there is no gadolinium-based contrast agent available for conventional magnetic resonance imaging (MRI) detection of amyloidal beta (Aβ) plaques in Alzheimer's disease (AD). Its timely finding would be vital for patient survival and quality of life. Curcumin (CUR), a common Indian spice effectively binds to Aβ plaques which is a hallmark of AD. To address this binding, we have designed a novel nanoimaging agent (NIA) based on nature-derived poly(β-l-malic acid) (PMLA) containing covalently attached gadolinium-DOTA(Gd-DOTA) and nature-derived CUR. The all-in-one agent recognizes and selectively binds to Aβ plaques and is detected by MRI. It efficiently detected Aβ plaques in human and mouse samples by an ex vivo staining. The method can be useful in clinic for safe and noninvasive diagnosis of AD. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. [Cardiovascular depression and intravascular hemolysis secondary to ethanol injection for arteriovenous malformation].

    Science.gov (United States)

    Cai, Mei-Hua; Su, Li-Xin; Qiu, Lin

    2016-08-01

    Ethanol is the only liquid embolization agent which can cure arteriovenous malformation. Complications of ethanol embolization are not rare including local tissue injury, intravascular hemolysis and cardiovascular depression even collapse, etc. This report presented a case of long time cardiovascular depression and intravascular hemolysis secondary to ethanol embolotherapy of right ear. In order to avoid the fatal complications that are associated with ethanol sclerotherapy, anesthesiologists should consider the use of continuously invasive hemodynamic monitoring while surgeons should carefully choose the dose of ethanol.

  19. DCE-MRI using small-molecular and albumin-binding contrast agents in experimental carcinomas with different stromal content

    Energy Technology Data Exchange (ETDEWEB)

    Farace, Paolo; Merigo, Flavia; Fiorini, Silvia; Nicolato, Elena; Tambalo, Stefano; Daducci, Alessandro [Department of Morphological-Biomedical Sciences, Section of Anatomy and Histology, University of Verona, Verona (Italy); Degrassi, Anna [Nerviano Medical Sciences Institute, Milan (Italy); Sbarbati, Andrea [Department of Morphological-Biomedical Sciences, Section of Anatomy and Histology, University of Verona, Verona (Italy); Rubello, Domenico, E-mail: domenico.rubello@libero.it [Department of Radiology, Nuclear Medicine, Medical Physics, Services of Radiology and Nuclear Medicine, ' S. Maria della Misericordia' Hospital, Viale Tre Martiri 140, 45100 Rovigo (Italy); Marzola, Pasquina [Department of Morphological-Biomedical Sciences, Section of Anatomy and Histology, University of Verona, Verona (Italy)

    2011-04-15

    Objectives: To compare DCE-MRI experiments performed using a standard small-molecular (Gd-DTPA) and an albumin-binding (MS-325) contrast agent in two carcinoma models with different stromal content. Materials and methods: DU-145 or BXPC-3 cancer cells were subcutaneously injected into nude mice. DCE-MRI was performed by a bolus injection of Gd-DTPA or MS-325 about 2 weeks after inoculation. For quantitative analysis a volume of interest was manually drawn over each tumor. To address the heterogeneous enhancement, each tumor volume was then divided into the 20% most-enhancing and the remaining 80% least-enhancing fractions. Mean tumor enhancement was calculated over these selected tumor volumes and compared between tumor groups and contrast agents. Maps of differential enhancement, peak enhancement and time-to-peak were used for visual evaluation. CD31 and VEGF immunohistochemistry were performed in excised tumors. Results: In the 80% least-enhancing volume, at late time points of the dynamic scan, the mean enhancement elicited by MS-325 was higher in BXPC-3 than in DU-145 tumors. In the 20% most-enhancing volume, using either contrast agents, significant difference between the two tumors types were observed only early, while at later time points of the dynamic scan the difference were obscured by the faster washout observed in the BXPC-3 tumors. Enhancement maps confirmed that BXPC-3 tumors were characterized by marked washout rate using either contrast agent, particularly in the higher enhancing peripheral rim. With MS-325 this washout pattern appeared to be specific to the BXPC-3 carcinomas, since it was not observed in the DU-145 tumors. Finally, in both tumor types, MS-325 produced significantly higher enhancement than Gd-DTPA in the late phase of the dynamic scan. Ex vivo analysis confirmed the marked presence of aberrant infiltrative stroma in BXPC-3 tumors, in which tumor vessels were embedded. In all tumors the central portion was less viable and less

  20. Functionalized multimodal ZnO@Gd2O3 nanosystems to use as perspective contrast agent for MRI

    Science.gov (United States)

    Babayevska, Nataliya; Florczak, Patryk; Woźniak-Budych, Marta; Jarek, Marcin; Nowaczyk, Grzegorz; Zalewski, Tomasz; Jurga, Stefan

    2017-05-01

    The main aim of this research was the synthesis of the multimodal hybrid ZnO@Gd2O3 nanostructures as prospective contrast agent for Magnetic Resonance Imaging (MRI) for bio-medical applications. The nanoparticles surface was functionalized by organosilicon compounds (OSC) then, by folic acid (FA) as targeting agent and doxorubicin (Dox) as chemotherapeutic agent. Doxorubicin and folic acid were attached to the nanoparticles surface by amino groups as well as due to attractive physical interactions. The morphology and crystallography of the nanostructures were studied by HRTEM and SAXS techniques. After ZnO nanoparticles surface modification by Gd3+ and annealing at 900 °C, ZnO@Gd2O3 nanostructures are polydispersed with size 30-100 nm. NMR (Nuclear Magnetic Resonance) studies of ZnO@Gd2O3 were performed on fractionated particles with size up to 50 nm. Fourier transform infrared spectroscopy (FTIR), UV-vis spectroscopy, zeta-potential measurements and energy dispersive X-ray analysis (EDX) showed that functional groups have been effectively bonded onto the nanoparticles surface. The high adsorption capacity of folic acid (up to 20%) and doxorubicin (up to 40%) on nanoparticles was reached upon 15 min of adsorption process in a temperature-dependent manner. The nuclear magnetic resonance (NMR) relaxation measurements confirmed that the obtained ZnO@Gd2O3 nanostructures could be good contrast agents, useful for magnetic resonance imaging.

  1. A Functional Iron Oxide Nanoparticles Modified with PLA-PEG-DG as Tumor-Targeted MRI Contrast Agent.

    Science.gov (United States)

    Xiong, Fei; Hu, Ke; Yu, Haoli; Zhou, Lijun; Song, Lina; Zhang, Yu; Shan, Xiuhong; Liu, Jianping; Gu, Ning

    2017-08-01

    Tumor targeting could greatly promote the performance of magnetic nanomaterials as MRI (Magnetic Resonance Imaging) agent for tumor diagnosis. Herein, we reported a novel magnetic nanoparticle modified with PLA (poly lactic acid)-PEG (polyethylene glycol)-DG (D-glucosamine) as Tumor-targeted MRI Contrast Agent. In this work, we took use of the D-glucose passive targeting on tumor cells, combining it on PLA-PEG through amide reaction, and then wrapped the PLA-PEG-DG up to the Fe 3 O 4 @OA NPs. The stability and anti phagocytosis of Fe 3 O 4 @OA@PLA-PEG-DG was tested in vitro; the MRI efficiency and toxicity was also detected in vivo. These functional magnetic nanoparticles demonstrated good biocompatibility and stability both in vitro and in vivo. Cell experiments showed that Fe 3 O 4 @OA@PLA-PEG-DG nanoparticles exist good anti phagocytosis and high targetability. In vivo MRI images showed that the contrast effect of Fe 3 O 4 @OA@PLA-PEG-DG nanoparticles prevailed over the commercial non tumor-targeting magnetic nanomaterials MRI agent at a relatively low dose. The DG can validly enhance the tumor-targetting effect of Fe 3 O 4 @OA@PLA-PEG nanoparticle. Maybe MRI agents with DG can hold promise as tumor-targetting development in the future.

  2. Multicenter analysis of tolerance and clinical safety of the extracellular MR contrast agent gadobenate dimeglumine (MultiHance registered)

    International Nuclear Information System (INIS)

    Herborn, Christoph U.; Jaeger-Booth, I.; Goyen, M.; Lodemann, K.P.; Spinazzi, A.

    2009-01-01

    Purpose: Retrospective analysis of the occurrence of adverse events and the diagnostic efficacy of a paramagnetic contrast agent with weak intermittent protein binding and high relaxivity. Materials end methods: Postmarketing surveillance studies for gadobenate dimeglumine (MultiHance, BRACCO Altana Pharma, Constance) were conducted in Germany between 1998 and 2006 and then retrospectively analyzed. Demographic data, relevant comorbidities, and allergies were recorded. The safety and tolerability of MultiHance were logged on a standardized data sheet. Results: A total of 38568 patients were included in the study. 829 patients (2.1%) had a known intolerance against contrast media. The examined regions included the central nervous system, the liver, and the vascular bed. The injection rate with automated injectors (n = 10456) varied between 1.0 und 3.0 ml/sec in 86.5% of patients. Adverse events totaled 1.2%. 11 patients (0.03%) experienced serious adverse events. The most frequent findings were nausea, vomiting and a feeling of warmth. Conclusion: MultiHance is a safe and very well tolerated contrast agent for magnetic resonance imaging (MRI) with a profile and frequency of adverse events similar to other extracellular MR contrast materials. (orig.)

  3. Ultrasonic Analysis of Peptide- and Antibody-Targeted Microbubble Contrast Agents for Molecular Imaging of αvβ3-Expressing Cells

    Directory of Open Access Journals (Sweden)

    Paul A. Dayton

    2004-04-01

    Full Text Available The goal of targeted ultrasound contrast agents is to significantly and selectively enhance the detection of a targeted vascular site. In this manuscript, three distinct contrast agents targeted to the αvβ3 integrin are examined. The αvβ3 integrin has been shown to be highly expressed on metastatic tumors and endothelial cells during neovascularization, and its expression has been shown to correlate with tumor grade. Specific adhesion of these contrast agents to αvβ3-expressing cell monolayers is demonstrated in vitro, and compared with that of nontargeted agents. Acoustic studies illustrate a backscatter amplitude increase from monolayers exposed to the targeted contrast agents of up to 13-fold (22 dB relative to enhancement due to control bubbles. A linear dependence between the echo amplitude and bubble concentration was observed for bound agents. The decorrelation of the echo from adherent targeted agents is observed over successive pulses as a function of acoustic pressure and bubble density. Frequency–domain analysis demonstrates that adherent targeted bubbles exhibit high-amplitude narrowband echo components, in contrast to the primarily wideband response from free microbubbles. Results suggest that adherent targeted contrast agents are differentiable from free-floating microbubbles, that targeted contrast agents provide higher sensitivity in the detection of angiogenesis, and that conventional ultrasound imaging techniques such as signal subtraction or decorrelation detection can be used to detect integrin-expressing vasculature with sufficient signal-to-noise.

  4. Improved evaluation of antivascular cancer therapy using constrained tracer-kinetic modeling for multi-agent dynamic contrast-enhanced MRI

    NARCIS (Netherlands)

    Hectors, Stefanie; Jacobs, Igor; Lok, Jasper; Peters, Johannes; Bussink, Johan; Hoeben, Freek J. M.; Keizer, Henk; Janssen, Henk M.; Nicolay, Klaas; Schabel, Matthias; Strijkers, Gustav

    2018-01-01

    Dynamic contrast-enhanced MRI (DCE-MRI) is a promising technique for assessing the response of tumor vasculature to anti-vascular therapies. Multi-agent DCE-MRI employs a combination of low and high molecular weight contrast agents, which potentially improves the accuracy of estimation of tumor

  5. Quinine-Induced Disseminated Intravascular Coagulation

    Directory of Open Access Journals (Sweden)

    Firas Abed

    2016-01-01

    Full Text Available Every drug comes with some side effect. It is the benefit/risk ratio that determines the medical use of the drug. Quinine, a known antimalarial drug, has been used for nocturnal leg cramps since the 1930s; it is associated with severe life-threatening hematological and cardiovascular side effects. Disseminated intravascular coagulation (DIC, albeit rare, is a known coagulopathy associated with Quinine. It is imperative to inquire about the Quinine intake in medication history in patients with coagulopathy, as most patients still consider it a harmless home remedy for nocturnal leg cramps. In this report, we present a case of coagulopathy in a middle-aged woman, who gave a history of taking Quinine for nocturnal leg cramps, as her home remedy. Early identification of the offending agent led to the diagnosis, prompt discontinuation of the medication, and complete recovery and prevented the future possibility of recurrence.

  6. Scientific and industrial challenges of developing nanoparticle-based theranostics and multiple-modality contrast agents for clinical application

    Science.gov (United States)

    Wáng, Yì Xiáng J.; Idée, Jean-Marc; Corot, Claire

    2015-10-01

    Designing of theranostics and dual or multi-modality contrast agents are currently two of the hottest topics in biotechnology and biomaterials science. However, for single entity theranostics, a right ratio of their diagnostic component and their therapeutic component may not always be realized in a composite suitable for clinical application. For dual/multiple modality molecular imaging agents, after in vivo administration, there is an optimal time window for imaging, when an agent is imaged by one modality, the pharmacokinetics of this agent may not allow imaging by another modality. Due to reticuloendothelial system clearance, efficient in vivo delivery of nanoparticles to the lesion site is sometimes difficult. The toxicity of these entities also remains poorly understood. While the medical need of theranostics is admitted, the business model remains to be established. There is an urgent need for a global and internationally harmonized re-evaluation of the approval and marketing processes of theranostics. However, a reasonable expectation exists that, in the near future, the current obstacles will be removed, thus allowing the wide use of these very promising agents.

  7. Adverse reactions after the use of sulphur hexafluoride (SonoVue) echo contrast agent.

    Science.gov (United States)

    Geleijnse, Marcel L; Nemes, Attila; Vletter, Wim B; Michels, Michelle; Soliman, Osama I I; Caliskan, Kadir; Galema, Tjebbe W; ten Cate, Folkert J

    2009-01-01

    The aim of the present study was to analyse the adverse effects of SonoVue echo contrast in a consecutive series of 352 cardiac patients during a 4-year period. During 352 consecutive cardiac SonoVue studies, seven patients (2.0%) experienced adverse effects. Four patients (1.1%) had mild allergic reactions causing skin erythema and mild sinus tachycardia, and three patients (0.9%) experienced a severe allergic reaction resulting in (nonfatal) shock. The reported incidence of adverse effects of SonoVue echo contrast in this consecutive series of cardiac patients seems markedly higher than those reported in a company postmarketing analysis.

  8. Acute renal failure related to oxaliplatin-induced intravascular hemolysis.

    Science.gov (United States)

    Ulusakarya, Ayhan; Misra, Srimanta; Haydar, Mazen; Habert, Hélène; Castagne, Vincent; Gumus, Yusuf; Delmas-Marsalet, Béatrice; Machover, David

    2010-12-01

    Oxaliplatin is an effective chemotherapeutic agent frequently used in the treatment of colorectal carcinoma. Rare cases of renal failure and hemolytic reactions have been reported as separate side effects of oxaliplatin. Here we present a clinical picture of immune-related intravascular hemolysis and acute tubular necrosis in a patient receiving this drug. This case suggests a mechanistic explanation of renal failure in patients treated with oxaliplatin.

  9. Improved double emulsion technology for fabricating autofluorescent microcapsules as novel ultrasonic/fluorescent dual-modality contrast agents.

    Science.gov (United States)

    Gong, An; Ma, Xuehua; Xiang, Lingchao; Ren, Wenzhi; Shen, Zheyu; Wu, Aiguo

    2014-04-01

    The aim of this study is to explore an improved double emulsion technology with in situ reaction of lysine (Lys) and glutaraldehyde (GA) for fabricating autofluorescent Lys-poly(lactic-co-glycolic acid)-GA (Lys-PLGA-GA) microcapsules as novel ultrasonic/fluorescent dual-modality contrast agents. Scanning electron microscope (SEM) and static light scattering (SLS) results show that 80% of the Lys-PLGA-GA microcapsules are larger than 1.0 μm and 90% of them are smaller than 8.9 μm. SEM and laser confocal scanning microscope (LCSM) data demonstrate that the structure of our Lys-PLGA-GA microcapsules is hollow. Compared with the FT-IR spectrum of PLGA microcapsules, a new peak at 1,644 cm(-1) in that of Lys-PLGA-GA microcapsules confirms the formed Schiff base in Lys-PLGA-GA microcapsules. LCSM images and fluorescence spectra show that our Lys-PLGA-GA microcapsules exhibit bright and stable autofluorescence without conjugation to any fluorescent agent, which can be ascribed to the n-π transitions of the CN bonds in the formed Schiff base. Our autofluorescent Lys-PLGA-GA microcapsules might have more wide applications than traditional fluorescent dyes because their excitation and emission spectra are both broad. The fluorescence intensity can also be tuned by the feeding amount of Lys and GA. The MTT assays reveal that the autofluorescent microcapsules are biocompatible. The results of fluorescent imaging in cells and in vitro ultrasonic imaging demonstrate the feasibility of our autofluorescent Lys-PLGA-GA microcapsules as ultrasonic/fluorescent dual-modality contrast agents. This novel ultrasonic/fluorescent dual-modality contrast agent might have potential for a variety of biological and medical applications. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Imaging in Vivo Extracellular pH with a Single Paramagnetic Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast Agent

    Directory of Open Access Journals (Sweden)

    Guanshu Liu

    2012-01-01

    Full Text Available The measurement of extracellular pH (pHe has potential utility for cancer diagnoses and for assessing the therapeutic effects of pH-dependent therapies. A single magnetic resonance imaging (MRI contrast agent that is detected through paramagnetic chemical exchange saturation transfer (PARACEST was designed to measure tumor pHe throughout the range of physiologic pH and with magnetic resonance saturation powers that are not harmful to a mouse model of cancer. The chemical characterization and modeling of the contrast agent Yb3+-1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid, 10-o-aminoanilide (Yb-DO3A-oAA suggested that the aryl amine of the agent forms an intramolecular hydrogen bond with a proximal carboxylate ligand, which was essential for generating a practical chemical exchange saturation transfer (CEST effect from an amine. A ratio of CEST effects from the aryl amine and amide was linearly correlated with pH throughout the physiologic pH range. The pH calibration was used to produce a parametric pH map of a subcutaneous flank tumor on a mouse model of MCF-7 mammary carcinoma. Although refinements in the in vivo CEST MRI methodology may improve the accuracy of pHe measurements, this study demonstrated that the PARACEST contrast agent can be used to generate parametric pH maps of in vivo tumors with saturation power levels that are not harmful to a mouse model of cancer.

  11. High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted MR Images: Comparison between Gadobutrol and Linear Gadolinium-Based Contrast Agents.

    Science.gov (United States)

    Moser, F G; Watterson, C T; Weiss, S; Austin, M; Mirocha, J; Prasad, R; Wang, J

    2018-02-01

    In view of the recent observations that gadolinium deposits in brain tissue after intravenous injection, our aim of this study was to compare signal changes in the globus pallidus and dentate nucleus on unenhanced T1-weighted MR images in patients receiving serial doses of gadobutrol, a macrocyclic gadolinium-based contrast agent, with those seen in patients receiving linear gadolinium-based contrast agents. This was a retrospective analysis of on-site patients with brain tumors. Fifty-nine patients received only gadobutrol, and 60 patients received only linear gadolinium-based contrast agents. Linear gadolinium-based contrast agents included gadoversetamide, gadobenate dimeglumine, and gadodiamide. T1 signal intensity in the globus pallidus, dentate nucleus, and pons was measured on the precontrast portions of patients' first and seventh brain MRIs. Ratios of signal intensity comparing the globus pallidus with the pons (globus pallidus/pons) and dentate nucleus with the pons (dentate nucleus/pons) were calculated. Changes in the above signal intensity ratios were compared within the gadobutrol and linear agent groups, as well as between groups. The dentate nucleus/pons signal ratio increased in the linear gadolinium-based contrast agent group ( t = 4.215, P linear gadolinium-based contrast agent group ( t = 2.931, P linear gadolinium-based contrast agents. © 2018 by American Journal of Neuroradiology.

  12. Targeted delivery of cancer-specific multimodal contrast agents for intraoperative detection of tumor boundaries and therapeutic margins

    Science.gov (United States)

    Xu, Ronald X.; Xu, Jeff S.; Huang, Jiwei; Tweedle, Michael F.; Schmidt, Carl; Povoski, Stephen P.; Martin, Edward W.

    2010-02-01

    Background: Accurate assessment of tumor boundaries and intraoperative detection of therapeutic margins are important oncologic principles for minimal recurrence rates and improved long-term outcomes. However, many existing cancer imaging tools are based on preoperative image acquisition and do not provide real-time intraoperative information that supports critical decision-making in the operating room. Method: Poly lactic-co-glycolic acid (PLGA) microbubbles (MBs) and nanobubbles (NBs) were synthesized by a modified double emulsion method. The MB and NB surfaces were conjugated with CC49 antibody to target TAG-72 antigen, a human glycoprotein complex expressed in many epithelial-derived cancers. Multiple imaging agents were encapsulated in MBs and NBs for multimodal imaging. Both one-step and multi-step cancer targeting strategies were explored. Active MBs/NBs were also fabricated for therapeutic margin assessment in cancer ablation therapies. Results: The multimodal contrast agents and the cancer-targeting strategies were tested on tissue simulating phantoms, LS174 colon cancer cell cultures, and cancer xenograft nude mice. Concurrent multimodal imaging was demonstrated using fluorescence and ultrasound imaging modalities. Technical feasibility of using active MBs and portable imaging tools such as ultrasound for intraoperative therapeutic margin assessment was demonstrated in a biological tissue model. Conclusion: The cancer-specific multimodal contrast agents described in this paper have the potential for intraoperative detection of tumor boundaries and therapeutic margins.

  13. Gd(III) complexes with tripodal pyridine carboxylate ligands: application to optimized contrast agents for NMR Imaging; Complexes de Gd(III) avec des ligands tripodes pyridinocarboxylate: vers des agents de contraste optimises pour l'IRM

    Energy Technology Data Exchange (ETDEWEB)

    Nonat, A.; Gateau, Ch.; Mallanti, M.; Fries, P. [CEA Grenoble, Dept. de Recherche Fondamentale sur la Matiere Condensee (DRFMC/SCIB/LAI) Lab. de Reconnaissance Ionique, 38 (France)

    2005-07-01

    In order to better understand the influence of the pyridine carboxylate units on the stability and the electronic relaxation time, and with the aim to obtain gadolinium complexes leading to next generation contrast agents having very high relaxivity, the octadente analogous of the tpatcn which has a water molecule bound in the first coordination sphere has been studied. Here is presented the synthesis, the structural studies, the thermodynamic and relaxometric properties of the Ln(III) complexes of this new tripodal compound 1-carboxy-methyl-4,7-bis[(6-carboxy-pyridin-2-yl)methyl] - 1,4,7-tri-aza-cyclo-nonane. (O.M.)

  14. Application of parametric ultrasound contrast agent perfusion studies for differentiation of hyperplastic adrenal nodules from adenomas-Initial study.

    Science.gov (United States)

    Slapa, Rafal Z; Kasperlik-Zaluska, Anna A; Migda, Bartosz; Otto, Maciej; Jakubowski, Wiesław S

    2015-08-01

    To evaluate the possibilities of differentiation of non-malignant adrenal masses with the application of the new technique for the evaluation of enhancement after administration of an ultrasound contrast agent: parametric imaging. 34 non-malignant adrenal masses in 29 patients were evaluated in a dynamic examination after the administration of ultrasound contrast agent with parametric imaging. Patterns on parametric imaging of arrival time were evaluated. The final diagnosis was based on CT, MRI, biochemical studies, follow up and/or histopathology examination. The study included: 12 adenomas, 10 hyperplastic nodules, 7 myelolipomas, 3 pheochromocytomas, hemangioma with hemorrhage and cyst. The pattern of peripheral laminar inflow of Sonovue on parametric images of arrival time of was 100% sensitive for hyperplastic nodules and 83% specific in regard to adenomas. Parametric contrast enhanced ultrasound may accurately differentiate hyperplastic adrenal nodules from adenomas and could be complementary to CT or MRI. Incorporation of perfusion studies to CT or MRI could possibly enable one-shop complete characterization of adrenal masses. This could deliver additional information in diagnostics of patients with Conn Syndrome and warrants further studies in this cohort of patients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Application of parametric ultrasound contrast agent perfusion studies for differentiation of hyperplastic adrenal nodules from adenomas—Initial study

    Energy Technology Data Exchange (ETDEWEB)

    Slapa, Rafal Z., E-mail: rz.slapa@gmail.com [Diagnostic Imaging Department, Medical University of Warsaw, Second Faculty of Medicine with English and Physiotherapy Divisions, Warsaw (Poland); Kasperlik–Zaluska, Anna A. [Endocrinology Department, Center for Postgraduate Medical Education, Bielanski Hospital, Warsaw (Poland); Migda, Bartosz [Diagnostic Imaging Department, Medical University of Warsaw, Second Faculty of Medicine with English and Physiotherapy Divisions, Warsaw (Poland); Otto, Maciej [Department of General, Vascular and Transplant Surgery, Medical University of Warsaw, First Faculty of Medicine, Warsaw (Poland); Jakubowski, Wiesław S. [Diagnostic Imaging Department, Medical University of Warsaw, Second Faculty of Medicine with English and Physiotherapy Divisions, Warsaw (Poland)

    2015-08-15

    Highlights: • Adrenal masses may differ on parametric perfusion ultrasound. • Hyperplastic nodules present distinctive patterns on CEUS in regard to adenomas. • Adrenal lesions perfusion should be further investigated with different modalities. - Abstract: Objectives: To evaluate the possibilities of differentiation of non-malignant adrenal masses with the application of the new technique for the evaluation of enhancement after administration of an ultrasound contrast agent: parametric imaging. Patients and Methods: 34 non-malignant adrenal masses in 29 patients were evaluated in a dynamic examination after the administration of ultrasound contrast agent with parametric imaging. Patterns on parametric imaging of arrival time were evaluated. The final diagnosis was based on CT, MRI, biochemical studies, follow up and/or histopathology examination. Results: The study included: 12 adenomas, 10 hyperplastic nodules, 7 myelolipomas, 3 pheochromocytomas, hemangioma with hemorrhage and cyst. The pattern of peripheral laminar inflow of Sonovue on parametric images of arrival time of was 100% sensitive for hyperplastic nodules and 83% specific in regard to adenomas. Conclusions: Parametric contrast enhanced ultrasound may accurately differentiate hyperplastic adrenal nodules from adenomas and could be complementary to CT or MRI. Incorporation of perfusion studies to CT or MRI could possibly enable one-shop complete characterization of adrenal masses. This could deliver additional information in diagnostics of patients with Conn Syndrome and warrants further studies in this cohort of patients.

  16. Application of parametric ultrasound contrast agent perfusion studies for differentiation of hyperplastic adrenal nodules from adenomas—Initial study

    International Nuclear Information System (INIS)

    Slapa, Rafal Z.; Kasperlik–Zaluska, Anna A.; Migda, Bartosz; Otto, Maciej; Jakubowski, Wiesław S.

    2015-01-01

    Highlights: • Adrenal masses may differ on parametric perfusion ultrasound. • Hyperplastic nodules present distinctive patterns on CEUS in regard to adenomas. • Adrenal lesions perfusion should be further investigated with different modalities. - Abstract: Objectives: To evaluate the possibilities of differentiation of non-malignant adrenal masses with the application of the new technique for the evaluation of enhancement after administration of an ultrasound contrast agent: parametric imaging. Patients and Methods: 34 non-malignant adrenal masses in 29 patients were evaluated in a dynamic examination after the administration of ultrasound contrast agent with parametric imaging. Patterns on parametric imaging of arrival time were evaluated. The final diagnosis was based on CT, MRI, biochemical studies, follow up and/or histopathology examination. Results: The study included: 12 adenomas, 10 hyperplastic nodules, 7 myelolipomas, 3 pheochromocytomas, hemangioma with hemorrhage and cyst. The pattern of peripheral laminar inflow of Sonovue on parametric images of arrival time of was 100% sensitive for hyperplastic nodules and 83% specific in regard to adenomas. Conclusions: Parametric contrast enhanced ultrasound may accurately differentiate hyperplastic adrenal nodules from adenomas and could be complementary to CT or MRI. Incorporation of perfusion studies to CT or MRI could possibly enable one-shop complete characterization of adrenal masses. This could deliver additional information in diagnostics of patients with Conn Syndrome and warrants further studies in this cohort of patients

  17. Indirect caudal lymphography using a new water-soluble contrast agent - animal experimental studies in pigs

    International Nuclear Information System (INIS)

    Apitzsch, D.E.; Kroll, H.U.; Zuehlke, H.V.

    1981-01-01

    Animal experiments on caudal lymphography in pigs are presented, using a new water-soluble contrast medium which is renally excreted. Indirect cutaneous administration renders possible the radiological visualization of the entire lymphatic drainage system of the lower limb, the retro-peritoneal space and the thoracic duct. Visualization of the lymphatic system is rapid, homogeneous and can be repeated as often as desired. The quality of the lymphogram is as good as that obtained by the current methods in common use. (orig.)

  18. Laser-produced Au nanoparticles as X-ray contrast agents for diagnostic imaging

    Czech Academy of Sciences Publication Activity Database

    Torrisi, L.; Restuccia, N.; Cuzzocrea, S.; Paterniti, I.; Ielo, I.; Pergolizzi, S.; Cutroneo, Mariapompea; Kováčik, L.

    2017-01-01

    Roč. 50, č. 1 (2017), s. 51-60 ISSN 0017-1557 R&D Projects: GA MŠk LM2015056; GA ČR(CZ) GBP108/12/G108 Institutional support: RVO:61389005 Keywords : Au nanoparticles * Laser * X-ray diagnostics * medical imaging * contrast medium Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Inorganic and nuclear chemistry Impact factor: 1.638, year: 2016

  19. Avascular necrosis (AVN) of the proximal fragment in scaphoid nonunion: Is intravenous contrast agent necessary in MRI?

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, R., E-mail: schmitt.radiologie@herzchirurgie.de [Department of Diagnostic and Interventional Radiology, Cardiovascular Center, Bad Neustadt an der Saale (Germany); Christopoulos, G.; Wagner, M. [Department of Diagnostic and Interventional Radiology, Cardiovascular Center, Bad Neustadt an der Saale (Germany); Krimmer, H. [Department of Hand Surgery, Cardiovascular Center, Bad Neustadt an der Saale (Germany); Fodor, S. [Department of Diagnostic and Interventional Radiology, Cardiovascular Center, Bad Neustadt an der Saale (Germany); Schoonhoven, J. van; Prommersberger, K.J. [Department of Hand Surgery, Cardiovascular Center, Bad Neustadt an der Saale (Germany)

    2011-02-15

    Purpose: The purpose of this prospective study is to assess the diagnostic value of intravenously applied contrast agent for diagnosing osteonecrosis of the proximal fragment in scaphoid nonunion, and to compare the imaging results with intraoperative findings. Materials and methods: In 88 patients (7 women, 81 men) suffering from symptomatic scaphoid nonunion, preoperative MRI was performed (coronal PD-w FSE fs, sagittal-oblique T1-w SE nonenhanced and T1-w SE fs contrast-enhanced, sagittal T2*-w GRE). MRI interpretation was based on the intensity of contrast enhancement: 0 = none, 1 = focal, 2 = diffuse. Intraoperatively, the osseous viability was scored by means of bleeding points on the osteotomy site of the proximal scaphoid fragment: 0 = absent, 1 = moderate, 2 = good. Results: Intraoperatively, 17 necrotic, 29 compromised, and 42 normal proximal fragments were found. In nonenhanced MRI, bone viability was judged necrotic in 1 patient, compromised in 20 patients, and unaffected in 67 patients. Contrast-enhanced MRI revealed 14 necrotic, 21 compromised, and 53 normal proximal fragments. Judging surgical findings as the standard of reference, statistical analysis for nonenhanced MRI was: sensitivity 6.3%, specificity 100%, positive PV 100%, negative PV 82.6%, and accuracy 82.9%; statistics for contrast-enhanced MRI was: sensitivity 76.5%, specificity 98.6%, positive PV 92.9%, negative PV 94.6%, and accuracy 94.3%. Sensitivity for detecting avascular proximal fragments was significantly better (p < 0.001) in contrast-enhanced MRI in comparison to nonenhanced MRI. Conclusion: Viability of the proximal fragment in scaphoid nonunion can be significantly better assessed with the use of contrast-enhanced MRI as compared to nonenhanced MRI. Bone marrow edema is an inferior indicator of osteonecrosis. Application of intravenous gadolinium is recommended for imaging scaphoid nonunion.

  20. Avascular necrosis (AVN) of the proximal fragment in scaphoid nonunion: Is intravenous contrast agent necessary in MRI?

    International Nuclear Information System (INIS)

    Schmitt, R.; Christopoulos, G.; Wagner, M.; Krimmer, H.; Fodor, S.; Schoonhoven, J. van; Prommersberger, K.J.

    2011-01-01

    Purpose: The purpose of this prospective study is to assess the diagnostic value of intravenously applied contrast agent for diagnosing osteonecrosis of the proximal fragment in scaphoid nonunion, and to compare the imaging results with intraoperative findings. Materials and methods: In 88 patients (7 women, 81 men) suffering from symptomatic scaphoid nonunion, preoperative MRI was performed (coronal PD-w FSE fs, sagittal-oblique T1-w SE nonenhanced and T1-w SE fs contrast-enhanced, sagittal T2*-w GRE). MRI interpretation was based on the intensity of contrast enhancement: 0 = none, 1 = focal, 2 = diffuse. Intraoperatively, the osseous viability was scored by means of bleeding points on the osteotomy site of the proximal scaphoid fragment: 0 = absent, 1 = moderate, 2 = good. Results: Intraoperatively, 17 necrotic, 29 compromised, and 42 normal proximal fragments were found. In nonenhanced MRI, bone viability was judged necrotic in 1 patient, compromised in 20 patients, and unaffected in 67 patients. Contrast-enhanced MRI revealed 14 necrotic, 21 compromised, and 53 normal proximal fragments. Judging surgical findings as the standard of reference, statistical analysis for nonenhanced MRI was: sensitivity 6.3%, specificity 100%, positive PV 100%, negative PV 82.6%, and accuracy 82.9%; statistics for contrast-enhanced MRI was: sensitivity 76.5%, specificity 98.6%, positive PV 92.9%, negative PV 94.6%, and accuracy 94.3%. Sensitivity for detecting avascular proximal fragments was significantly better (p < 0.001) in contrast-enhanced MRI in comparison to nonenhanced MRI. Conclusion: Viability of the proximal fragment in scaphoid nonunion can be significantly better assessed with the use of contrast-enhanced MRI as compared to nonenhanced MRI. Bone marrow edema is an inferior indicator of osteonecrosis. Application of intravenous gadolinium is recommended for imaging scaphoid nonunion.

  1. Informed consent for the administration of an intravenous contrast agent: importance and determinants of patient refusal

    International Nuclear Information System (INIS)

    Martel, J.; Garcia-Diaz, J. D.

    1999-01-01

    We proposed to determine the proportion of patients who refuse to undergo intravenous contrast administration and the factors that influence their refusal. Our series consisted of 442 patients who were supposed to undergo imaging studies involving the intravenous injection of an iodine contrast. In a personal interview, the patients were issued a questionnaire specifically designed for this study. The following parameters were recorded: sex, age, inpatient or outpatient status, medical history available, person who informed them about the procedure, person signing the informed consent (patient or other) , highest academic degree, attitude toward receiving the information and degree of concern after reading and signing the consent form. In our series 8.6% of the patients (95% confidence interval: 6-11.2) refused to sign the informed consent form. In addition, there were a number of patients who delayed the procedure or hindered the daily work schedule by some other means. When the relationship between each of the variables studied and refusal to sign the consent form was assessed, significant associations were observed between the latter and the academic level of the patient, his or her degree of concern and having received the information from a trained person. There was also a nearly significant trend toward the association between refusal and the patient's background. Relatively few patients refuse to sign the informed consent to receive intravenous contrast administration but this negative decision interferes with the health care practice. It is possible to identify certain correctable factors that influence the patient in this respect. (Author) 13 refs

  2. Non-degradable contrast agent with selective phagocytosis for cellular and hepatic magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Fei-Yan [Nanchang University, College of Chemistry (China); Gu, Zhe-Jia [Nanchang University, Institute for Advanced Study (China); Zhao, Dawen [UT Southwestern Medical Center, Department of Radiology (United States); Tang, Qun, E-mail: tangqun@ncu.edu.cn [Nanchang University, Institute for Advanced Study (China)

    2015-09-15

    Degradation is the long-existing toxic issue of metal-containing inorganic medicine. In this paper, we fully investigated the degradation of dextran-coated KMnF{sub 3} nanocube in the in vitro and in vivo surroundings. Different from the general decomposing and ion releasing events, this special agent is resistant to acidic environment, as well as ion exchange. Non-degradability was proved by simulated and real cellular experiments. Moreover, it can be engulfed in the macrophage cells and kept stable in the lysosome. Due to its stability and highly selective phagocytosis, implanted liver cancer can be clearly visualized after administration.

  3. Ex Vivo Perfusion-Simulation Measurements of Microbubbles as a Scattering Contrast Agent for Grating-Based X-Ray Dark-Field Imaging.

    Directory of Open Access Journals (Sweden)

    Astrid Velroyen

    Full Text Available The investigation of dedicated contrast agents for x-ray dark-field imaging, which exploits small-angle scattering at microstructures for contrast generation, is of strong interest in analogy to the common clinical use of high-atomic number contrast media in conventional attenuation-based imaging, since dark-field imaging has proven to provide complementary information. Therefore, agents consisting of gas bubbles, as used in ultrasound imaging for example, are of particular interest. In this work, we investigate an experimental contrast agent based on microbubbles consisting of a polyvinyl-alcohol shell with an iron oxide coating, which was originally developed for multimodal imaging and drug delivery. Its performance as a possible contrast medium for small-animal angiography was examined using a mouse carcass to realistically consider attenuating and scattering background signal. Subtraction images of dark field, phase contrast and attenuation were acquired for a concentration series of 100%, 10% and 1.3% to mimic different stages of dilution in the contrast agent in the blood vessel system. The images were compared to the gold-standard iodine-based contrast agent Solutrast, showing a good contrast improvement by microbubbles in dark-field imaging. This study proves the feasibility of microbubble-based dark-field contrast-enhancement in presence of scattering and attenuating mouse body structures like bone and fur. Therefore, it suggests a strong potential of the use of polymer-based microbubbles for small-animal dark-field angiography.

  4. Soil aggregation and aggregating agents as affected by long term contrasting management of an Anthrosol

    Science.gov (United States)

    Zhang, Shulan; Wang, Renjie; Yang, Xueyun; Sun, Benhua; Li, Qinghui

    2016-12-01

    Soil aggregation was studied in a 21-year experiment conducted on an Anthrosol. The soil management regimes consisted of cropland abandonment, bare fallow without vegetation and cropping system. The cropping system was combined with the following nutrient management treatments: control (CONTROL, no nutrient input); nitrogen, phosphorus and potassium (NPK); straw plus NPK (SNPK); and manure (M) plus NPK (MNPK). Compared with the CONTROL treatment, the abandonment treatment significantly increased the formation of large soil macroaggregates (>2 mm) and consequently improved the stability of aggregates in the surface soil layer due to enhancement of hyphal length and of soil organic matter content. However, in response to long-term bare fallow treatment aggregate stability was low, as were the levels of aggregating agents. Long term fertilization significantly redistributed macroaggregates; this could be mainly ascribed to soil organic matter contributing to the formation of 0.5-2 mm classes of aggregates and a decrease in the formation of the >2 mm class of aggregates, especially in the MNPK treatment. Overall, hyphae represented a major aggregating agent in both of the systems tested, while soil organic compounds played significantly different roles in stabilizing aggregates in Anthrosol when the cropping system and the soil management regimes were compared.

  5. Direct synthesis of magnetite nanoparticles from iron(II) carboxymethylcellulose and their performance as NMR contrast agents

    Science.gov (United States)

    da Silva, Delmarcio Gomes; Hiroshi Toma, Sergio; de Melo, Fernando Menegatti; Carvalho, Larissa Vieira C.; Magalhães, Alvicler; Sabadini, Edvaldo; dos Santos, Antônio Domingues; Araki, Koiti; Toma, e. Henrique E.

    2016-01-01

    Iron(II) carboxymethylcellulose (CMC) has been successfully employed in the synthesis of hydrophylic magnetite nanoparticles stabilized with a biopolymer coating, aiming applications in NMR imaging. The new method encompasses a convenient one-step synthetic procedure, allowing a good size control and yielding particles of about 10 nm (core size). In addition to the biocompatibility, the nanoparticles have promoted a drastic reduction in the transverse relaxation time (T2) of the water protons. The relaxivity rates have been investigated as a function of the nanoparticles concentration, showing a better performance in relation to the common NMR contrast agents available in the market.

  6. Enhancing contrast agents and radiotracers performance through hyaluronic acid-coating in neuroradiology and nuclear medicine.

    Science.gov (United States)

    Ganau, Mario; Syrmos, Nikolaos Ch; D'Arco, Felice; Ganau, Laura; Chibbaro, Salvatore; Prisco, Lara; Ligarotti, Gianfranco K I; Ambu, Rossano; Soddu, Andrea

    2017-01-01

    The use of hyaluronic acid nanoshells has been proposed to encapsulate prodrugs and exploit the mechanisms of interactions between living cells, like endocytes or cancer cells and hyaluronic acid, which is a natural component of the extracellular matrix. In this review we describe the potential and the limits of this promising research trend and discuss the theoretical advantages of such an engineering approach. Is it a possible scalability to increase the efficacy and biodegradability of molecules like contrast media and radiotracers especially for neuroradiology and nuclear medicine studies.

  7. Upper airway obstruction in infants and children: evaluation by tracheobronchography with a non-ionic contrast agent

    International Nuclear Information System (INIS)

    Lee Tain; Lee, S.K.

    1997-01-01

    The clinical benefits of tracheobronchograms using nonionic contrast medium were evaluated prospectively in ten infants and children with suspected airway obstruction who could not be weaned from endotracheal intubation and were in incubators. All patients were examined usedated. The contrast agent was injected via the intubation tube, pumped with an Ambu-bag (Manual Resuscitator, Formosa-CJ Health Business Corporation, Taiwan), and then a chest radiograph was obtained immediately in both anteroposterior and lateral views using portable equipment. Imaging results were correct in eight of ten cases as judged from bronchoscopic, surgical, and clinical data. No complications occurred during or after these examinations. This method provides an easy, safe, and helpful technique for diagnosis of the airway in nonsedated infants and children whose condition is critical. (orig.)

  8. Direct synthesis of magnetite nanoparticles from iron(II) carboxymethylcellulose and their performance as NMR contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Gomes da Silva, Delmarcio; Hiroshi Toma, Sergio; Menegatti de Melo, Fernando [Instituto de Química, Universidade de São Paulo, São Paulo, SP (Brazil); Carvalho, Larissa Vieira C.; Magalhães, Alvicler; Sabadini, Edvaldo [Instituto de Química, Universidade Estadual de Campinas – UNICAMP, Campinas, SP (Brazil); Domingues dos Santos, Antônio [Instituto de Física, Universidade de São Paulo, São Paulo, SP (Brazil); Araki, Koiti [Instituto de Química, Universidade de São Paulo, São Paulo, SP (Brazil); Toma, Henrique E., E-mail: henetoma@iq.usp.br [Instituto de Química, Universidade de São Paulo, São Paulo, SP (Brazil)

    2016-01-01

    Iron(II) carboxymethylcellulose (CMC) has been successfully employed in the synthesis of hydrophylic magnetite nanoparticles stabilized with a biopolymer coating, aiming applications in NMR imaging. The new method encompasses a convenient one-step synthetic procedure, allowing a good size control and yielding particles of about 10 nm (core size). In addition to the biocompatibility, the nanoparticles have promoted a drastic reduction in the transverse relaxation time (T{sub 2}) of the water protons. The relaxivity rates have been investigated as a function of the nanoparticles concentration, showing a better performance in relation to the common NMR contrast agents available in the market. - Highlights: • Stable, hydrophylic magnetic nanoparticles have been obtained. • Direct use of iron(II) carboxymethylcellulose improves the synthesis. • The magnetic nanoparticles exhibit high spin–spin relaxivity. • The particles promote dark contrast by decreasing the T{sub 2} relaxation time.

  9. MDCT appearance of the appendix: how does the low-density barium sulfate oral contrast agent affect it?

    Science.gov (United States)

    Yaghmai, Vahid; Aghaei-Lasboo, Anahita; Brandwein, Warren M; Tochetto, Sandra; Mafi, John N; Miller, Frank H; Nikolaidis, Paul

    2011-01-01

    We compared the effect of low-density barium sulfate neutral oral contrast agent on the diameter of normal appendix and its luminal content versus that of water on multidetector-row CT. CT scans of 24 patients who had been imaged on two separate occasions for the evaluation of pancreatic pathology, once with water and subsequently with low-density barium sulfate as the neutral oral contrast agent were evaluated (total of 48 scans). Studies were randomized and reviewed in consensus on a workstation in the stack mode by two radiologists blinded to the type of oral contrast. The appendix was measured at baseline and 10 days later to obtain an average diameter. Results of the water and low-density barium sulfate groups were compared using paired t test. Contents of the appendiceal lumen were also noted (gas, fluid, mixed, and collapsed appendix). The average diameter of the appendix for scans obtained with water and low-density barium sulfate was 4.09 ± 0.87 mm (median, 4.22 mm; range, 2.50-5.65 mm) and 4.13 ± 0.93 mm (median, 4 mm, range, 2.2-5.65 mm), respectively. This difference was not statistically significant (P = 0.69). There was no statistically significant difference in the appendiceal content when water or low-density barium sulfate were used as oral contrast (χ (2) = 4.25, P = 0.89). Low-density barium sulfate does not affect appendiceal content or diameter and, therefore, should not adversely affect evaluation of the appendix on multidetector row CT.

  10. 1,3,5-Trialkyl-2,4,6-triiodobenzenes: novel X-ray contrast agents for gastrointestinal imaging.

    Science.gov (United States)

    Estep, K G; Josef, K A; Bacon, E R; Illig, C R; Toner, J L; Mishra, D; Blazak, W F; Miller, D M; Johnson, D K; Allen, J M; Spencer, A; Wilson, S A

    2000-05-18

    Examination of the gastrointestinal (GI) tract has been performed for decades using barium sulfate. Although this agent has many recognized limitations including extreme radiopacity, poor intrinsic affinity for the GI mucosa, and very high density, no alternative contrast agents have emerged which produce comparable or better contrast visualization. In fact, the various techniques of the GI radiologic examination (i.e., single contrast, double contrast, biphasic) were developed to compensate for its limitations. Each of these techniques requires complex patient manipulation to achieve adequate mucosal coating or compression to overcome the marked radiopacity of barium sulfate in order to obtain a diagnostically useful examination. A series of novel radiopaque oils, the 1,3, 5-trialkyl-2,4,6-triiodobenzenes, was designed to improve the efficacy, stability, and safety of barium formulations. These substances were prepared in two steps from 1,3,5-trichlorobenzene. Compound 17 (1,3,5-tri-n-hexyl-2,4,6-triiodobenzene), formulated as an oil-in-water emulsion, was found to be well-tolerated in rodents (mice, hamsters, rats) following acute oral and/or intraperitoneal administrations at 4 times the anticipated human clinical dose. No metabolism of 17 was detected in rat, hamster, dog, monkey, or human hepatic microsomes, suggesting the lack of oral toxicity was a consequence of poor absorption. In imaging experiments in dogs, emulsions of 17 have demonstrated excellent mucosal coating and improved radiodensity relative to barium sulfate suspensions. On the basis of the preliminary imaging and toxicity data, compound 17 was selected as a potential development candidate.

  11. Estimation of single-kidney glomerular filtration rate without exogenous contrast agent.

    Science.gov (United States)

    He, Xiang; Aghayev, Ayaz; Gumus, Serter; Ty Bae, K

    2014-01-01

    Measurement of single-kidney filtration fraction and glomerular filtration rate (GFR) without exogenous contrast is clinically important to assess renal function and pathophysiology, especially for patients with comprised renal function. The objective of this study is to develop a novel MR-based tool for noninvasive quantification of renal function using conventional MR arterial spin labeling water as endogenous tracer. The regional differentiation of the arterial spin labeling water between the glomerular capsular space and the renal parenchyma was characterized and measured according to their MR relaxation properties (T1ρ or T2 ), and applied to the estimation of filtration fraction and single-kidney GFR. The proposed approach was tested to quantify GFR in healthy volunteers at baseline and after a protein-loading challenge. Biexponential decay of the cortical arterial spin labeling water MR signal was observed. The major component decays the same as parenchyma water; the minor component decays much slower as expected from glomerular ultra-filtrates. The mean single-kidney GFR was estimated to be 49 ± 9 mL/min at baseline and increased by 28% after a protein-loading challenge. We developed an arterial spin labeling-based MR imaging method that allows us to estimate renal filtration fraction and singe-kidney GFR without use of exogenous contrast. Copyright © 2013 Wiley Periodicals, Inc.

  12. Developments Toward Diagnostic Breast Cancer Imaging Using Near-Infrared Optical Measurements and Fluorescent Contrast Agents1

    Directory of Open Access Journals (Sweden)

    Daniel J. Hawrysz

    2000-09-01

    Full Text Available The use of near-infrared (NIR light to interrogate deep tissues has enormous potential for molecular-based imaging when coupled with NIR excitable dyes. More than a decade has now passed since the initial proposals for NIR optical tomography for breast cancer screening using time-dependent measurements of light propagation in the breast. Much accomplishment in the development of optical mammography has been demonstrated, most recently in the application of time-domain, frequency-domain, and continuous-wave measurements that depend on endogenous contrast owing to angiogenesis and increased hemoglobin absorbance for contrast. Although exciting and promising, the necessity of angiogenesis-mediated absorption contrast for diagnostic optical mammography minimizes the potential for using NIR techniques to assess sentinel lymph node staging, metastatic spread, and multifocality of breast disease, among other applications. In this review, we summarize the progress made in the development of optical mammography, and focus on the emerging work underway in the use of diagnostic contrast agents for the molecular-based, diagnostic imaging of breast.

  13. Contrast-enhanced computerized tomography combined with a targeted nanoparticle contrast agent for screening for early-phase non-small cell lung cancer.

    Science.gov (United States)

    Yuan, Ninglu; Zhang, Xiaohe; Cao, Yonghui; Jiang, Xiaojie; Zhao, Si; Feng, Yingying; Fan, Yimeng; Lu, Zhitao; Gao, Hongmei

    2017-11-01

    Non-small cell lung cancer (NSCLC) is a major cause of morbidity and mortality, and patients with NSCLC are frequently diagnosed at an advanced stage. This is primarily due to a lack of advanced and sensitive protocols for the detection of early stage NSCLC. Therefore, methods for the accurate diagnosis of early stage NSCLC are urgently required to improve survival rates. The present study investigated the use of contrast-enhanced computerized tomography (CECT) combined with a targeted nanoparticle contrast agent (TNCA) to diagnose early-stage NSCLC in a mice xenograft model. The TNCA used was lenvatinib, a multi-target tyrosine kinase inhibitor that inhibits vascular endothelial growth factor receptor 1-3, fibroblast growth factor receptor 1-4, platelet-derived growth factor receptor β, proto-oncogene tyrosine-protein kinase receptor Ret and mast/stem cell growth factor receptor Kit. Xenograft NSCLC mice were established and used to analyze the efficacy of CECT-TNCA compared with CT scanning alone. The TNCA was inhaled with the use of an atomizer. The results demonstrated that CECT-TNCA improved the sensitivity of the diagnosis of early stage NSCLC. In addition, imaging using the TNCA enabled the visualization of nodules in the lung in mice with early stage NSCLC. In addition, lung nodule signal enhancement was increased in CECT-TNCA compared with CT, suggesting a high accurate accumulation of the TNCA in tumor nodules. Mice diagnosed with early stage NSCLC exhibited a higher eradication rate of NSCLC after treatment with cisplatin compared with mice with advanced stage NSCLC. These data indicate that the sensitivity and accuracy of CT imaging for the diagnosis of early stage NSCLC was improved through combination with the liposome-encapsulated TNCA.

  14. Preparation of biopolymer-coated magnetite nanoparticles for magnetic resonance image contrast agent.

    Science.gov (United States)

    Cho, J H; Ko, S G; Ahn, Y K; Song, K C; Choi, E J

    2009-02-01

    The magnetite nanoparticles were synthesized using the sonochemical method with oleic acid as surfactant. The average size of the magnetite particles can be controlled by the ratio R = [H2O]/[surfactant] in the range of 2 to 9 nm. The size of the magnetite nanoparticles prepared by this method shows the narrow distribution. To prepare biopolymer(beta-glucan)-coated magnetite nanoparticles, beta-glucan solution was added to the magnetic colloid suspensions under the ultrasonication at room temperature. The beta-glucan coated magnetite colloidal suspensions of various concentrations did not agglomerate for 15 days, indicating their good stability. The beta-glucan-coated magnetite colloidal suspensions exhibited the enhancement of MRI contrasts in vitro.

  15. Line-scanning confocal microscopy for high-resolution imaging of upconverting rare-earth-based contrast agents

    Science.gov (United States)

    Higgins, Laura M.; Zevon, Margot; Ganapathy, Vidya; Sheng, Yang; Tan, Mei Chee; Riman, Richard E.; Roth, Charles M.; Moghe, Prabhas V.; Pierce, Mark C.

    2015-01-01

    Abstract. Rare-earth (RE) doped nanocomposites emit visible luminescence when illuminated with continuous wave near-infrared light, making them appealing candidates for use as contrast agents in biomedical imaging. However, the emission lifetime of these materials is much longer than the pixel dwell times used in scanning intravital microscopy. To overcome this limitation, we have developed a line-scanning confocal microscope for high-resolution, optically sectioned imaging of samples labeled with RE-based nanomaterials. Instrument performance is quantified using calibrated test objects. NaYF4:Er,Yb nanocomposites are imaged in vitro, and in ex vivo tissue specimens, with direct comparison to point-scanning confocal microscopy. We demonstrate that the extended pixel dwell time of line-scanning confocal microscopy enables subcellular-level imaging of these nanomaterials while maintaining optical sectioning. The line-scanning approach thus enables microscopic imaging of this emerging class of contrast agents for preclinical studies, with the potential to be adapted for real-time in vivo imaging in the clinic. PMID:26603495

  16. Biodegradable human serum albumin nanoparticles as contrast agents for the detection of hepatocellular carcinoma by magnetic resonance imaging.

    Science.gov (United States)

    Watcharin, Waralee; Schmithals, Christian; Pleli, Thomas; Köberle, Verena; Korkusuz, Hüdayi; Huebner, Frank; Zeuzem, Stefan; Korf, Hans W; Vogl, Thomas J; Rittmeyer, Claudia; Terfort, Andreas; Piiper, Albrecht; Gelperina, Svetlana; Kreuter, Jörg

    2014-05-01

    Tumor visualization by magnetic resonance imaging (MRI) and nanoparticle-based contrast agents may improve the imaging of solid tumors such as hepatocellular carcinoma (HCC). In particular, human serum albumin (HSA) nanoparticles appear to be a suitable carrier due to their safety and feasibility of functionalization. In the present study HSA nanoparticles were conjugated with gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) using carbodiimide chemistry. The nanoparticles had a uniform spherical shape and a diameter of 235±19nm. For better optical visualization in vitro and in vivo, the HSA-Gd nanoparticles were additionally labeled with rhodamine 123. As shown by confocal microscopy and flow cytometry analysis, the fluorescent nanoparticles were readily taken up by Huh-7 hepatocellular carcinoma cells. After 24h incubation in blood serum, less than 5% of the Gd(III) was released from the particles, which suggests that this nanoparticulate system may be stable in vivo and, therefore, may serve as potentially safe T1 MRI contrast agent for MRI of hepatocellular carcinoma. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Transformation of the Ionic X-Ray Contrast Agent Diatrizoate and Related Triiodinated Benzoates by Trametes versicolor

    Science.gov (United States)

    Rode, Ulrike; Müller, Rudolf

    1998-01-01

    Iodinated X-ray contrast agents are considered to be nondegradable by microorganisms. The decomposition of the ionic X-ray contrast agents Diatrizoate (3,5-di(acetamido)-2,4,6-triiodobenzoic acid) and Iodipamide (3,3′-adipoyl-diimino-di(2,4,6-triiodobenzoic acid) and related triiodinated benzoates (Acetrizoate [3-acetylamino-2,4,6-triiodobenzoic acid] and Aminotrizoate [3-amino-2,4,6-triiodobenzoic acid]) by Trametes versicolor has been investigated. The fungus was able to transform all tested triiodinated benzoates cometabolically. During transformation of these compounds, iodide was released, but deiodination was not complete. T. versicolor liberated traces of 14CO2 from uniformly ring-14C-labeled Diatrizoate (3,5-di(acetamido)-2,4,6-triiodobenzoate). Various extracellular metabolites were detected during transformation of the different substances. In the transformation of Diatrizoate, the three main metabolites were identified as 3,5-di(acetamido)-2,6-diiodobenzoic acid, 3,5-di(acetamido)-2,4-diiodobenzoic acid, and 3,5-di(acetamido)-2-iodobenzoic acid, suggesting reductive deiodinations in steps as initial transformation steps. PMID:9687487

  18. Synthesis and characterization of PVP-functionalized superparamagnetic Fe3O4 nanoparticles as an MRI contrast agent

    Directory of Open Access Journals (Sweden)

    2010-06-01

    Full Text Available The magnetite (Fe3O4 nanoparticles (MNPs coated with poly(N-vinyl pyrrolidone (PVP via covalent bonds were prepared as T2 contrast agent for magnetic resonance imaging (MRI. The surface of MNPs was first coated with 3-(trimethoxysilyl propyl methacrylate (silan A by a silanization reaction to introduce reactive vinyl groups onto the surface, then poly(N-vinyl pyrrolidone was grafted onto the surface of modified-MNPs via surface-initiated radical polymerization. The obtained nanoparticles were characterized by FT-IR (Fourier transform infrared spectroscopy, XRD (X-ray diffraction, TEM (transmission electron microscopy, VSM (vibrating sample magnetometer, and TGA (thermogravimetric analysis. The MNPs had an average size of 14 nm and exhibited superparamagnetism and high saturation magnetization at room temperature. T2-weighted MRI images of PVP-grafted MNPs showed that the magnetic resonance signal is enhanced significantly with increasing nanoparticle concentration in water. The r1 and r2 values per millimole Fe, and r2/r1 value of the PVP-grafted MNPs were calculated to be 2.6 , 72.1, and 28.1(mmol/l–1•s–1, respectively. These results indicate that the PVP-grafted MNPs have great potential for application in MRI as a T2 contrast agent.

  19. Antibiofouling polymer-coated superparamagnetic iron oxide nanoparticles as potential magnetic resonance contrast agents for in vivo cancer imaging.

    Science.gov (United States)

    Lee, Haerim; Lee, Eunhye; Kim, Do Kyung; Jang, Nam Kyu; Jeong, Yong Yeon; Jon, Sangyong

    2006-06-07

    We report the fabrication and characterization of antifouling polymer-coated magnetic nanoparticles as nanoprobes for magnetic resonance (MR) contrast agents. Magnetite superparamagnetic iron oxide nanoparticles (SPION) were coated with the protein- or cell-resistant polymer, poly(TMSMA-r-PEGMA), to generate stable, protein-resistant MR probes. Coated magnetic nanoparticles synthesized using two different preparation methods (in situ and stepwise, respectively) were both well dispersed in PBS buffer at a variety of pH conditions (pH 1-10). In addition, dynamic light scattering data revealed that their sizes were not altered even after 24 h of incubation in 10% serum containing cell culture medium, indicative of a lack of protein adsorption on their surfaces. When the antibiofouling polymer-coated SPION were incubated with macrophage cells, uptake was significantly lower in comparison to that of the popular contrast agent, Feridex I.V., suggesting that the polymer-coated SPION can be long-circulated in plasma by escaping from uptake by the reticular endothelial system (RES) such as macrophages. Indeed, when the coated SPION were administered to tumor xenograft mice by intravenous injection, the tumor could be detected in T2-weighted MR images within 1 h as a result of the accumulation of the nanomagnets within the tumor site. Although the poly(TMSMA-r-PEGMA)-coated SPION do not have any targeting ligands on their surface, they are potentially useful for cancer diagnosis in vivo.

  20. Gadolinium based contrast agents in current practice: Risks of accumulation and toxicity in patients with normal renal function

    Directory of Open Access Journals (Sweden)

    Anju Ranga

    2017-01-01

    Full Text Available Despite being decked as the most prized compounds in the nugget box of contrast agents for clinical radiologists, and carrying an indisputable tag of safety of the US Food and Drug Administration for close to three decades, all may not be seemingly well with the family of gadolinium compounds. If the first signs of violations of primum non nocere in relation to gadolinium-based contrast agents (GBCAs appeared in the millennium year with the first published report of skin fibrosis in patients with compromised renal function, the causal relationship between the development of nephrogenic systemic fibrosis (NSF and GBCAs, first proposed by two European groups in 2006, further precluded their use in renocompromised patients. The toxicity, pharmacokinetics, and pharmacodynamics of GBCAs, however, has come under hawk-eyed scrutiny with recent reports that gadolinium tends to deposit cumulatively in the brain of patients with normal hepatobiliary function and intact blood–brain barrier. While the jury on the long-term hazard significance of this critical scientific finding is still out, the use of GBCAs must be guided by due clinical diligence, avoidance of repeated doses, and preferring GBCAs with the best safety profiles.

  1. Newer techniques for intravascular and intraoperative neurointerventional procedures

    International Nuclear Information System (INIS)

    Higashida, R.T.; Halbach, V.V.; Hieshima, G.B.; Yang, P.

    1987-01-01

    A videotape demonstrating newer techniques used in intravascular and intraoperative embolization procedures will be presented. The authors discuss the use of some of the newer embolic agents, real-time digital subtraction angiography, roadmapping techniques, and the use of microcatheters and steerable micro guide wires, which has greatly facilitated neurovascullar embolization procedures and enhanced patient safety. A number of actual intraoperative and intravascular cases will be shown demonstrating treatment of vascular malformations of the brain and spinal cord, carotid cavernous sinus fistulas, aneurysms and dural arteriovenous malformations. The indications for treatment, patient selection, technical preparation and newer methodologies and approaches to complex vascular lesions of the brain and spinal cord are discussed in detail

  2. In vivo 3D PIXE-micron-CT imaging of Drosophila melanogaster using a contrast agent

    Science.gov (United States)

    Matsuyama, Shigeo; Hamada, Naoki; Ishii, Keizo; Nozawa, Yuichiro; Ohkura, Satoru; Terakawa, Atsuki; Hatori, Yoshinobu; Fujiki, Kota; Fujiwara, Mitsuhiro; Toyama, Sho

    2015-04-01

    In this study, we developed a three-dimensional (3D) computed tomography (CT) in vivo imaging system for imaging small insects with micrometer resolution. The 3D CT imaging system, referred to as 3D PIXE-micron-CT (PIXEμCT), uses characteristic X-rays produced by ion microbeam bombardment of a metal target. PIXEμCT was used to observe the body organs and internal structure of a living Drosophila melanogaster. Although the organs of the thorax were clearly imaged, the digestive organs in the abdominal cavity could not be clearly discerned initially, with the exception of the rectum and the Malpighian tubule. To enhance the abdominal images, a barium sulfate powder radiocontrast agent was added. For the first time, 3D images of the ventriculus of a living D. melanogaster were obtained. Our results showed that PIXEμCT can provide in vivo 3D-CT images that reflect correctly the structure of individual living organs, which is expected to be very useful in biological research.

  3. Multifunctional polyelectrolyte microcapsules as a contrast agent for photoacoustic imaging in blood.

    Science.gov (United States)

    Yashchenok, Alexey M; Jose, Jithin; Trochet, Philippe; Sukhorukov, Gleb B; Gorin, Dmitry A

    2016-08-01

    The polyelectrolyte microcapsules that can be accurate either visualized in biological media or in tissue would enhance their further in vivo application both as a carrier of active payloads and as a specific sensor. The immobilization of active species, for instance fluorescent dyes, quantum dots, metal nanoparticles, in polymeric shell enables visualization of capsules by optical imaging techniques in aqueous solution. However, for visualization of capsules in complex media an instrument with high contrast modality requires. Herein, we show for the first time photoacoustic imaging (PAI) of multifunctional microcapsules in water and in blood. The microcapsules exhibit greater photoacoustic intensity compare to microparticles with the same composition of polymeric shell presumably their higher thermal expansion. Photoacoustic intensity form microcapsules dispersed in blood displays an enhancement (2-fold) of signal compare to blood. Photoacoustic imaging of microcapsules might contribute to non-invasive carrier visualization and further their in vivo distribution. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents

    International Nuclear Information System (INIS)

    Harabis, Vratislav; Kolar, Radim; Mezl, Martin; Jirik, Radovan

    2013-01-01

    Dynamic contrast-enhanced ultrasound (DCE-US) imaging is a promising diagnostic method, which enables the evaluation of tissue perfusion via different parameters. The mean transit time and time-to-peak parameters are the main time parameters and their values depend on the model used for the approximation of the noisy perfusion curves. In this paper, we described a new comparison of different perfusion models using a tissue mimicking phantom. The following models were compared: log-normal, lagged, Erlang, Gamma and the local density random walk model. We discovered that the mean-square error is not the best criterion for model evaluation. More important is the comparison between the estimated time perfusion parameters and the physical parameters of the developed tissue mimicking phantom. Based on the statistical analysis, we can suggest that for the DCE-US perfusion analysis more models should be used, excluding the log-normal model, which gives the highest error of mean transit time value. (paper)

  5. Radio-contrast agent-induced hyperthyroidism: case report and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Iakovou, Ioannis, E-mail: iiakovou@auth.gr, E-mail: iiakovou@icloud.com [Nuclear Medicine Department, Papageorgiou Hospital, Thessaloniki (Greece); Zapandiotis, Apostolos; Mpalaris, Vassileios; Goulis, Dimitrios G. [Medical School, Aristotle University of Thessaloniki (Greece)

    2016-11-01

    A 66 year-old woman with a history of a euthyroid multinodular goiter underwent a head and neck computed tomography (CT) scan (total iodine load of 35 g) in order to evaluate the extent of retrosternal expansion. Less than 24 h after the iodine-based contrast media (ICM) administration, she presented with symptoms and laboratory findings typical of thyrotoxicosis. She was treated successfully with antithyroid medications. This is the shortest time reported in the literature and it is of clinical importance, as it may have an impact to the recommendations given by the attending physician. Given the fact that a large number of ICM examinations are performed in everyday practice, physicians should be aware of this possible thyroid-specific effect. Prophylactic drugs could be considered in high-risk populations, such as administration of perchlorate and a thionamide class drug to elderly patients with suppressed TSH and/or palpable goiter, started the day before and continued for two weeks after ICM administration. (author)

  6. Heat as a contrast agent to enhance thermal imaging of blood vessels

    Science.gov (United States)

    Case, Jason R.; Trammell, Susan R.; Young, Madison A.; Israel, Uriah; Crown, Michael X.

    2013-03-01

    In this study we test the feasibility of using low-cost LEDs to selectivity heat blood for enhanced thermal imaging of vascular structures. Applications of this new imaging technique include mapping blood vessels during surgeries such as tumor removal and vascular repair. In addition, this technique could potentially be used to determine the location of increased vascular density, and thus breast cancer tumors. Porcine blood, skeletal muscle, skin and fat were illuminated with LEDs that emit at 405 nm and 530 nm (near the blood absorption peaks) and the increase in temperature as a function of time was recorded using a thermal camera. In the studies with the 530 nm LED, blood heated more than other tissue types and the heating rate for the blood was significantly faster than other tissues. Illumination of blood with the 530 nm LED at low powers (tissue irradiance tissue. Illumination with the 405 nm LED produced large temperature changes (up to 15°C) at low LED powers (tissue irradiance muscle tissue was dependent on the skeletal muscle type, but most samples showed heating comparable to or larger than blood. This LED was not effective at selectively heating blood relative to the other tissue types. The results of the preliminary studies suggest that the best contrast can be achieved with pulsed 530 nm LED illumination and an image analysis method that highlights rapid changes in temperature.

  7. Radio-contrast agent-induced hyperthyroidism: case report and review of the literature

    International Nuclear Information System (INIS)

    Iakovou, Ioannis; Zapandiotis, Apostolos; Mpalaris, Vassileios; Goulis, Dimitrios G.

    2016-01-01

    A 66 year-old woman with a history of a euthyroid multinodular goiter underwent a head and neck computed tomography (CT) scan (total iodine load of 35 g) in order to evaluate the extent of retrosternal expansion. Less than 24 h after the iodine-based contrast media (ICM) administration, she presented with symptoms and laboratory findings typical of thyrotoxicosis. She was treated successfully with antithyroid medications. This is the shortest time reported in the literature and it is of clinical importance, as it may have an impact to the recommendations given by the attending physician. Given the fact that a large number of ICM examinations are performed in everyday practice, physicians should be aware of this possible thyroid-specific effect. Prophylactic drugs could be considered in high-risk populations, such as administration of perchlorate and a thionamide class drug to elderly patients with suppressed TSH and/or palpable goiter, started the day before and continued for two weeks after ICM administration. (author)

  8. Surfactant-controlled morphology and magnetic property of manganese ferrite nanocrystal contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Hu He; Tian Zhiqing; Liang Jie; Yang Hong; Dai Antao; An Lu; Wu Huixia; Yang Shiping, E-mail: shipingy@shnu.edu.cn [Department of Chemistry, Shanghai Normal University, No.100 Guilin Road, Shanghai 200234 (China)

    2011-02-25

    MnFe{sub 2}O{sub 4} nanocrystals (NCs) coated with three different surfactants (oleic acid, oleylamine or 1,2-hexadecanediol) and their mixtures, with sizes in range 6-12 nm, were synthesized by high-temperature decomposition of organometallic precursors. The effects of morphology and surface chemistry of MnFe{sub 2}O{sub 4} NCs on the magnetic properties were systematically investigated by comparing their saturation magnetization values and their capability to improve the negative contrast for magnetic resonance imaging (MRI) after converting the hydrophobic NCs to hydrophilic ones by a ligand exchange protocol. An important finding is that the magnetization values and proton relaxivity rates of MnFe{sub 2}O{sub 4} NCs are strongly dependent on the size and surface state of the particles that covalently bonded with different hydrophobic ligands before ligand exchange. In particular, monodisperse cubic MnFe{sub 2}O{sub 4} NCs could be obtained when oleylamine and 1,2-hexadecanediol were used as mixed stabilizers, and showed excellent morphology and magnetic properties. Furthermore, the low cytotoxicity and good cell uptake MR imaging of the dopamine capped MnFe{sub 2}O{sub 4} NCs make them promising candidates for use as bio-imaging probes.

  9. A Novel Foam Contrast Agent Suitable for Fluoroscopic Interventional Procedure: Comparative Study of Physical Properties and Experimental Intervention in Animal Model

    Directory of Open Access Journals (Sweden)

    Jin Ho Hwang

    2015-01-01

    Full Text Available In fluoroscopic contrast study for interventional procedure, liquid contrast agent may be diluted in body fluid, losing its contrast effect. We developed a novel contrast agent of “foam state” to maintain contrast effect for enough time and performed a comparative study of physical properties and its usefulness in experimental intervention in animal model. The mean size of microbubble of foam contrast was 13.8±3.6 µm. The viscosity was 201.0±0.624 cP (centipoise and the specific gravity was 0.616. The foam decayed slowly and it had 97.5 minutes of half-life. In terms of the sustainability in a slow flow environment, foam contrast washed out much more slowly than a conventional contrast. In experimental colonic stent placement, foam contrast revealed significantly better results than conventional contrast in procedure time, total amount of contrast usage, and the number of injections (p<0.05. Our foam contrast has high viscosity and low specific gravity and maintains foam state for a sufficient time. Foam contrast with these properties was useful in experimental intervention in animal model. We anticipate that foam contrast may be applied to various kinds of interventional procedures.

  10. Observation of contrast agent response to chirp insonation with a simultaneous optical-acoustical system.

    Science.gov (United States)

    Sun, Yang; Zhao, Shukui; Dayton, Paul A; Ferrara, Katherine W

    2006-06-01

    Rayleigh-Plesset analysis, ultra-high speed photography, and single bubble acoustical recordings previously were applied independently to characterize the radial oscillation and resulting echoes from a microbubble in response to an ultrasonic pulse. In addition, high-speed photography has shown that microbubbles are destroyed over a single pulse or pulse train by diffusion and fragmentation. In order to develop a single model to characterize microbubble echoes based on oscillatory and destructive characteristics, an optical-acoustical system was developed to simultaneously record the optical image and backscattered echo from each microbubble. Combined observation provides the opportunity to compare predictions for oscillation and echoes with experimental results and identify discrepancies due to diffusion or fragmentation. Optimization of agents and insonating pulse parameters may be facilitated with this system. The mean correlation of the predicted and experimental radius-time curves and echoes exceeds 0.7 for the parameters studied here. An important application of this new system is to record and analyze microbubble response to a long pulse in which diffusion is shown to occur over the pulse duration. The microbubble response to an increasing or decreasing chirp is evaluated using this new tool. For chirp insonation beginning with the lower center frequency, low-frequency modulation of the oscillation envelope was obvious. However, low-frequency modulation was not observed in the radial oscillation produced by decreasing chirp insonation. Comparison of the echoes from similar sized microbubbles following increasing and decreasing chirp insonation demonstrated that the echoes were not time-reversed replicas. Using a transmission pressure of 620 kPa, the -6 dB echo length was 0.9 and 1.1 micros for increasing and decreasing chirp insonation, respectively (P = 0.02). The mean power in the low-frequency portion of the echoes was 8 (mV)2 and 13 (mV)2 for increasing

  11. Superparamagnetic maghemite nanoparticles from solid-state synthesis – Their functionalization towards peroral MRI contrast agent and magnetic carrier for trypsin immobilization

    Czech Academy of Sciences Publication Activity Database

    Kluchová, K.; Zbořil, R.; Tuček, J.; Pečová, M.; Zajoncová, L.; Šafařík, Ivo; Mašláň, M.; Marková, I.; Jančík, D.; Šebela, M.; Bartoňková, H.; Bellesi, V.; Novák, P.; Petridis, D.

    2009-01-01

    Roč. 30, - (2009), s. 2855-2863 ISSN 0142-9612 Institutional research plan: CEZ:AV0Z60870520 Keywords : maghemite * contrast agent * composites Subject RIV: CE - Biochemistry Impact factor: 7.365, year: 2009

  12. Whole-body MR angiography with body coil acquisition at 3 T in patients with peripheral arterial disease using the contrast agent gadofosveset trisodium

    DEFF Research Database (Denmark)

    Nielsen, Yousef W; Eiberg, Jonas P; Løgager, Vibeke B

    2009-01-01

    Whole-body magnetic resonance angiography (WB-MRA) at 3 T with body coil acquisition has not previously been investigated. In this study, WB-MRA was performed in this manner using the blood pool contrast agent gadofosveset trisodium....

  13. Beispiel einer kontrastiven Grammatik: Der unbestimmte Agens im Deutschen und im Italienischen (An Example of Contrastive Grammar: The Indefinite Agent in German and Italian).

    Science.gov (United States)

    Schwarze, Christoph

    1977-01-01

    Discusses, using German and Italian as an example, sentences containing the indefinite agent (German "man") and reflexive and passive constructions, showing contrasts between equivalent structures in the two languages. (IFS/WGA)

  14. Magnetomotive imaging of iron oxide nanoparticles as cellular contrast agents for optical coherence tomography

    Science.gov (United States)

    Cimalla, Peter; Werner, Theresa; Gaertner, Maria; Mueller, Claudia; Walther, Julia; Wittig, Dierk; Ader, Marius; Karl, Mike; Koch, Edmund

    2013-06-01

    Recent studies in animal models provided proof-of-principle evidence for cell transplantation as a potential future therapeutic approach for retinal pathologies in humans such as Retinitis pigmentosa or age-related macular degeneration. In this case, donor cells are injected into the eye in order to protect or replace degenerating photoreceptors or retinal pigment epithelium. However, currently there is no three-dimensional imaging technique available that allows tracking of cell migration and integration into the host tissue under in vivo conditions. Therefore, we investigate about magnetomotive optical coherence tomography (OCT) of substances labeled with iron oxide nanoparticles as a potential method for noninvasive, three-dimensional cell tracking in the retina. We use a self-developed spectral domain OCT system for high-resolution imaging in the 800 nm-wavelength region. A suitable AC magnetic field for magnetomotive imaging was generated using two different setups, which consist of an electrically driven solenoid in combination with a permanent magnet, and a mechanically driven all-permanent magnet configuration. In the sample region the maximum magnetic flux density was 100 mT for both setups, with a field gradient of 9 T/m and 13 T/m for the solenoid and the allpermanent magnet setup, respectively. Magnetomotive OCT imaging was performed in elastic tissue phantoms and single cells labeled with iron oxide nanoparticles. Particle-induced sub-resolution movement of the elastic samples and the single cells could successfully be detected and visualized by means of phase-resolved Doppler OCT analysis. Therefore, this method is a potential technique to enhance image contrast of specific cells in OCT.

  15. Clinical application of ferric-pyrophosphate soluble as a contrast agent for MRI of obstructive jaundice

    Energy Technology Data Exchange (ETDEWEB)

    Yokota, Hajime; Matoba, Munetaka; Takarada, Akira; Tonami, Hisao; Okimura, Teturou; Yamamoto, Itaru; Yamaguchi, Kenzo (Kanazawa Medical Univ., Ishikawa (Japan))

    1992-10-01

    Indication of magnetic resonance imaging (MRI) for the biliary tract system is of limited value in view of motion artifacts and others. In an effort to visualize lesions causing obstructive jaundice, approximately 20 ml of ferric-pyrophosphate (0.5[approx]30 mmol/L) was used as contrast medium in MRI examination. The subjects were 16 patients, who underwent transhepatic cholangeal drainage (PTCD) for obstructive jaundice attributable to pancreas head (n=6), cancer of the biliary tract (n=6), metastatic lymphadenopathy (n=3), and choledocholithiasis (n=one). Signal intensity associated with various diluted solutions of ferric-pyrophosphate was determined on T[sub 1]-weighted images. The clearest and highest intensity images were obtained on T[sub 1]-weighted images enhanced with 1.0 mmol/L of ferric-pyrophosphate soluble. Injection of ferric pyrophosphate into the iliary tract through PTCD-tube allowed clear visualization of the intraheptic bile duct on MRI. The dilatated biliary tract was clearly detected in all 16 patients. Stone responsible for causing obstruction was also shown as a signal void area in the common bile duct at the end of dilatation. For cancer of the pancreatic head, tumor invasion to both the common bile duct and the end of the stenotic site was visualized simultaneously. For cancer of the common duct, tumor was visualized as low signal intensity at the end of the common bile duct. None of the side effects were encountered. MRI with ferric-pyrophosphate was considered more helpful in the detection of not only obstructive lesions in the biliary tract but also tumor invasion into the surrounding tissue. (N.K.).

  16. DNA transfer and cell killing in epidermoid cells by diagnostic ultrasound activation of contrast agent gas bodies in vitro.

    Science.gov (United States)

    Miller, Douglas L; Dou, Chunyan; Song, Jianming

    2003-04-01

    DNA transfer by sonoporation and cell killing in monolayer cells were examined by contrast-aided low-power diagnostic ultrasound (US). Culture chambers with epidermoid cell monolayers were scanned at about 1 mm/s with a 1.5-MHz scan head aimed upward at the chamber in a 37 degrees C water bath. For DNA transfer tests, plasmids coding for green fluorescent protein (GFP) were added to the medium, and GFP expression was assessed by flow cytometry after 2 days. In separate tests, cell killing was determined immediately after treatment. GFP-positive cell counts were 0.4% (0.7% SD) for shams and 3.7% (1.2% SD) of cells for exposure at 2.3 MPa with 2% Optison contrast agent. The fraction of dead cells was 3.4% (1.7% SD) in shams and 28.6% (6.3% SD) in exposed chambers. Both effects increased for increasing Optison concentration and increasing peak rarefactional pressure amplitude. Contrast-aided diagnostic US has a potential therapeutic application for gene transfer, but a trade-off appears to exist with cell killing.

  17. Godobenate dimeglumine as an intrabiliary contrast agent: comparison with mangafodipir trisodium with respect to non-dilated biliary tree depiction

    International Nuclear Information System (INIS)

    Lim, Joon Seok; Kim, Myeong Jin; Jung, Yong Yun; Kim, Ki Whang

    2005-01-01

    To compare the efficacy of Mangafodipir trisodium (Mn-DPDP)-enhanced MR cholangiogrphy (MRC) and Gadobenate dimeglumine (Gd-BOPTA)-enhanced MRC in visualizing a non-dilated biliary system. Eighty-eight healthy liver donor candidates underwent contrast-enhanced T1-weighted MRC. Mn-DPDP and Gd-BOPTA was used in 36 and 52 patients, respectively. Two radiologists reviewed the MR images and rated the visualization of the common duct, the right and left hepatic ducts, and the second-order branches using a 4-point scale. The contrast-to-noise ratio (CNR) of the common duct to the liver in the two groups was also compared. Mn-DPDP MRC and Gd-BOPTA MRC both showed similar visualization grades in the common duct (ρ = .380, Mann-Whitney U test). In the case of the proximal bile ducts, the median visualization grade was significantly higher with Gd-BOPTA MRC than with Mn-DPDP MRC (right hepatic duct: ρ = 0.016, left hepatic duct: ρ = 0.014, right secondary order branches: ρ = 0.006, left secondary order branches, ρ = 0.003). The common duct-to-liver CNR of the Gd-BOPTA MRC group was significantly higher (38.90 ± 24.50) than that of the Mn-DPDP MRC group (24.14 ± 17.98) (ρ = .003, Student's t test). Gd-BOPTA, as a biliary contrast agent, is a potential substitute for Mn-DPDP

  18. The effective use of acai juice, blueberry juice and pineapple juice as negative contrast agents for magnetic resonance cholangiopancreatography in children

    International Nuclear Information System (INIS)

    Bittman, Mark E.; Callahan, Michael J.

    2014-01-01

    Magnetic resonance cholangiopancreatography (MRCP) is commonly performed in the evaluation of known or suspected pancreaticobiliary disease in children. The administration of a negative oral contrast agent can improve the quality of the examination without significant additional cost. We describe our experience with certain brands of acai juice, blueberry juice and pineapple juice as negative oral contrast agents in children. We believe these fruit juices are safe, palatable and may improve MRCP image quality. (orig.)

  19. Conjugation Magnetic PAEEP-PLLA Nanoparticles with Lactoferrin as a Specific Targeting MRI Contrast Agent for Detection of Brain Glioma in Rats

    OpenAIRE