Sample records for intravascular brachytherapy sources

  1. Application of Gafchromic registered film in the dosimetry of an intravascular brachytherapy source

    International Nuclear Information System (INIS)

    Song Haijun; Roa, D. Eduardo; Yue Ning; D'Errico, Francesco; Chen Zhe; Nath, Ravinder

    2006-01-01

    The methodology of brachytherapy source dosimetry with Gafchromic registered MD 55-2 film (ISP Technologies, Inc.) is examined with an emphasis on the nonlinearity of the optical density-dose relation within the dynamic dose range, the radial distance-dependent measurement uncertainty, and the format of data presentation. The specific source chosen for this study was a Checkmate trade mark sign (Cordis Corporation) intravascular brachytherapy system. The two-dimensional dose distribution around the source was characterized by a comprehensive analysis of measurement uncertainties. A comparative analysis of the dosimetric data from the vendor and from the scientific literature showed a substantial consistency of the information available for the Checkmate trade mark sign source. Our two-dimensional dosimetric data for the Checkmate trade mark sign source trains is presented in the form of measured along and away dose tables

  2. Dosimetry in intravascular brachytherapy

    International Nuclear Information System (INIS)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing 32 P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  3. Effectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code

    Directory of Open Access Journals (Sweden)

    Baghani HR

    2013-12-01

    Full Text Available Background and Objective: The most common intravascular brachytherapy sources include 32P, 188Re, 106Rh and 90Sr/90Y. In this research, skin absorbed dose for different covering materials in dealing with these sources were evaluated and the best covering material for skin protection and reduction of absorbed dose by radiation staff was recognized and recommended. Method: Four materials including polyethylene, cotton and two different kinds of plastic were proposed as skin covers and skin absorbed dose at different depths for each kind of the materials was calculated separately using the VARSKIN3 code. Results: The results suggested that for all sources, skin absorbed dose was minimized when using polyethylene. Considering this material as skin cover, maximum and minimum doses at skin surface were related to 90Sr/90Y and 106Rh, respectively. Conclusion: polyethylene was found the most effective cover in reducing skin dose and protecting the skin. Furthermore, proper agreement between the results of VARSKIN3 and other experimental measurements indicated that VRASKIN3 is a powerful tool for skin dose calculations when working with beta emitter sources. Therefore, it can be utilized in dealing with the issue of radiation protection.

  4. Dosimetric model for intravascular brachytherapy

    International Nuclear Information System (INIS)

    Flower, E.E.; Stroud, D.B.

    2000-01-01

    Full text: Intravascular brachytherapy has been shown to be a prophylaxis for restenosis. Adventitial macrophages, which are extremely radiosensitive, initiate neointima formation. A model of the dose levels of the treatment range is developed, assuming that the adventitia is the target tissue. If the adventitia receives a dose of less than 10 Gy, it is assumed the treatment will be ineffective. If the dose to any part of the wall is above 30 Gy, it is assumed that the treatment could be detrimental. Hence the treatment range is between 10 and 30 Gy, with 20 Gy being the optimum dosage to the adventitia. An algorithm using numerical integration of published dose kernels calculates the dose at any point surrounding a beta ( 32 P) line source of finite length. Dose profiles were obtained to demonstrate edge effects. For long lesions, the source is often stepped along the artery. Dose changes due to separation or overlapping of sources during source stepping procedures were also determined. Isodose curves were superimposed on intravascular ultrasound images to demonstrate dose levels. For an exposure time of 60 seconds with a 200mCi source, the optimum dose of 20 Gy occurs at a distance 1.94mm from the centre of the source. The upper limit of the treatment dose range (30 Gy) occurs at 1.59mm. The lower limit of the treatment dose range (10 Gy) occurs at 2.7mm. Significant perturbations to the treatment dose range can be caused by non-centering of the source, edge effects and separation or overlapping of sources in stepping procedures. Despite these concerns, many successful procedures have been reported and this implies that the model is over simplified and requires modifications. Copyright (2000) Australasian College of Physical Scientists and Engineers in Medicine

  5. Dosimetric calculus in intravascular brachytherapy; Calculos dosimetricos em braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia Pumilla Botelho; Stabin, Michael Gregory [Pernambuco Univ., Recife, PE (Brazil). Dept. de Energia Nuclear

    2000-07-01

    Among the cardiovascular diseases, the most common is acute myocardial infarction, which occurs because of the occlusion of one or more coronary arteries. Balloon angioplasty has been a popular treatment which is less invasive than surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment). Known as Intravascular Brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis. In order to study the radiation dosimetry in the patient and radiological protection for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, 0.30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several radionuclides. Two stent sources employing {sup 32}P are also simulated. Advantages and disadvantages of the radionuclides and source geometries are discussed and the dosimetry developed here will aid in the realization of the benefits obtained in patients. (author)

  6. Monte Carlo dose characterization of a new 90Sr/90Y source with balloon for intravascular brachytherapy

    International Nuclear Information System (INIS)

    Wang Ruqing; Li, X. Allen; Lobdell, John

    2003-01-01

    Beta emitting source wires or seeds have been adopted in clinical practice of intravascular brachytherapy for coronary vessels. Due to the limitation of penetration depth, this type of source is normally not applicable to treat vessels with large diameter, e.g., peripheral vessel. In the effort to extend application of its beta source for peripheral vessels, Novoste has recently developed a new catheter-based system, the Corona trade mark sign 90 Sr/ 90 Y system. It is a source train of 6 cm length and is jacketed by a balloon. The existence of the balloon increases the penetration of the beta particles and maintains the source within a location away from the vessel wall. Using the EGSnrc Monte Carlo system, we have calculated the two-dimensional (2-D) dose rate distribution of the Corona trade mark sign system in water for a balloon diameter of 5 mm. The dose rates on the transverse axis obtained in this study are in good agreement with calibration results of the National Institute of Standards and Technology for the same system for balloon diameters of 5 and 8 mm. Features of the 2-D dose field were studied in detail. The dose parameters based on AAPM TG-60 protocol were derived. For a balloon diameter of 5 mm, the dose rate at the reference point (defined as r 0 =4.5 mm, 2 mm from the balloon surface) is found to be 0.010 28 Gy min -1 mCi -1 . A new formalism for a better characterization of this long source is presented. Calculations were also performed for other balloon diameters. The dosimetry for this source is compared with a 192 Ir source, commonly used for peripheral arteries. In conclusion, we have performed a detailed dosimetric characterization for a new beta source for peripheral vessels. Our study shows that, from dosimetric point of view, the Corona trade mark sign system can be used for the treatment of an artery with a large diameter, e.g., peripheral vessel

  7. Dosimetry in intravascular brachytherapy; Calculos dosimetricos em braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing {sup 32} P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  8. Preparation and evaluation of various 32P sources for intravascular brachytherapy

    International Nuclear Information System (INIS)

    Petelenz, B.U.; Bilski, P.; Ochab, E.; Rajchel, B.; Styczen, J.; Walichiewicz, P.; Wodniecki, J.; Wilczek, K.

    2001-01-01

    A relatively high per cent of restenoses, being a long-term complication of percutaneous transluminal coronary angioplasty (PTCA), can be significantly reduced by short-range ionizing radiation applied locally, immediately after PTCA. In search for dosimetrically favourable and easy to handle radiation sources for this purpose, we tried a pure β - emitter 32 P (t 1/2 =14.3 days). Ways of preparation of 32 P sources were the following: (1) Neutron activation of 31 P layers implanted into metallic surfaces by ionic methods; (2) Conversion coating of metallic surfaces in aqueous solutions containing 32 PO 4 3- ions; (3) Direct application of Na 2 H 32 PO 4 solutions in the angioplasty balloon. It was shown that: (1) 32 P sources obtained by 31 P ion implantation followed by neutron activation can be useful, but only if activation of the support material by thermal neutrons is negligible; (2) Phosphate layers on stainless steel surface exhibit rather poor adhesion. Similar layers on titanium require further studies; (3) Liquid 32 P sources ensure very good radial dose distribution but only utmost care in filling the balloon can give a reliable activity-dose dependence. Dosimetry of liquid sources, performed in a PMMA phantom by thermoluminescence method showed that 32 P sources of radioactive concentration of 200 MBq/cm 3 can deposit therapeutic dose during about 12 min of exposition. TL detectors manufactured for this purpose in our laboratory show very good spatial resolution and can be recommended for similar studies. (author)

  9. Model of distribution of dose for intravascular brachytherapy; Modelo de distribucion de dosis para braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Pirchio, Rosana; Signoretta, Catalina [Comision Nacional de Energia Atomica (CNEA), Buenos Aires (Argentina). Dosimetria de Radioaciones Ionizantes; Martin, Gabriela; Rivera, Elena; Bergoc, Rosa [Univeridad de Buenos Aires (Argentina). Facultad de Farmacia y Bioquimica. Lab. de Radioisotopos; Guzman, Luis [Instituto Cardiovascular de Buenos Aires (Argentina)

    2001-07-01

    In this work we present the radiation dose distributions for a theoretical model with Monte Carlo simulation, which was based on an experimental model developed for the study of the prevention of restenosis post-angioplasty employing intravascular brachytherapy. In the experimental model, the atherosclerotic plaques were induced in femoral arteries of male New Zealand rabbits through surgical intervention and later administration of cholesterol enriched diet. For the intravascular irradiation we employed a {sup 32} P source contained within the balloon used for the angioplasty. The radiation dose distributions were calculated using the Monte Carlo code MCNP4B according to a segment of a simulated artery. We studied the radiation dose distribution in the axial and radial directions for different thickness of the atherosclerotic plaques. The results will be correlated with the biologic effects observed by means of histological analysis of the irradiated arteries. (author)

  10. Design and implementation of an intravascular brachytherapy installation in cardiology

    International Nuclear Information System (INIS)

    Prieto, C.; Vano, E.; Fernandez, J.M.; Sabate, M.; Galvan, Y.C.

    2001-01-01

    Intravascular Brachytherapy (IVB) is a very promising technique for reducing restenosis rates. However, neither the exact absolute dose needed nor the optimal spatial and temporal distribution of dose inside the vessel wall for a successful treatment, nor the physical dosimetry of the various radioactive sources and devices for dose delivery, are well known. In this paper, an overview will be given of the design strategy, the dosimetric and radiation protection-related problems that we have met during the implementation of this technique at San Carlos hospital, adopted or foreseen solutions, and future research fields that we intend to carry out in order to reduce uncertainties and to achieve a deeper knowledge of the parameters that have an influence on the treatment. (author)

  11. Brachytherapy optimal planning with application to intravascular radiation therapy

    DEFF Research Database (Denmark)

    Sadegh, Payman; Mourtada, Firas A.; Taylor, Russell H.

    1999-01-01

    . Dose rate calculations are based on the sosimetry formulation of the American Association of Physicists in Medicine, Task Group 43. We apply the technique to optimal planning for intravascular brachytherapy of intimal hyperplasia using ultrasound data and 192Ir seeds. The planning includes...... determination of an optimal dwell-time sequence for a train of seeds that deliver ratiation while stepping through the vessel lesion. The results illustrate the advantage of this strategy over the common approach of delivering radiation by positioning a single train of seeds along the whole lesion....

  12. Monte Carol-Based Dosimetry of Beta-Emitters for Intravascular Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Choi, C.K.

    2002-06-25

    Monte Carlo simulations for radiation dosimetry and the experimental verifications of the simulations have been developed for the treatment geometry of intravascular brachytherapy, a form of radionuclide therapy for occluded coronary disease (restenosis). Monte Carlo code, MCNP4C, has been used to calculate the radiation dose from the encapsulated array of B-emitting seeds (Sr/Y-source train). Solid water phantoms have been fabricated to measure the dose on the radiochromic films that were exposed to the beta source train for both linear and curved coronary vessel geometries. While the dose difference for the 5-degree curved vessel at the prescription point of f+2.0 mm is within the 10% guideline set by the AAPM, however, the difference increased dramatically to 16.85% for the 10-degree case which requires additional adjustment for the acceptable dosimetry planning. The experimental dose measurements agree well with the simulation results

  13. Development of sup 1 sup 9 sup 2 Ir radiation sources for intravascular irradiation

    CERN Document Server

    Kogure, H; Iwamoto, S; Iwata, K; Kawauchi, Y; Nagata, Y; Sorita, T; Suzuki, K

    2003-01-01

    Intravascular brachytherapy is a novel therapy for preventing the restenosis of coronary artery by use of low-dose irradiation. JAERI and Kyoto University have been developing sup 1 sup 9 sup 2 Ir radiation sources by the cooperative research project entitled as 'The research on safety and effectiveness of the intravascular brachytherapy for preventing restenosis of the coronary artery disease' since 1998. The radiation source was introduced into the stenosis through a catheter (a guide-tube to insert directly into vascular) to irradiate the diseased part. Ten sup 1 sup 9 sup 2 Ir seed sources (phi 0.4 mm x 2.5 mm) were positioned between nylon spacers (phi 0.3 mm x 1.0 mm) in a flexible covering tube and the tube was plugged with a core-wire; the tube was shrunk to fix the inside materials and the size is 0.46 mm in diameter and 3 m in length. The physically optimal design was determined to insert the radiation source easily into vascular and to get the dose uniformity in the diseased part. The production me...

  14. 10 CFR 35.406 - Brachytherapy sources accountability.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Brachytherapy sources accountability. 35.406 Section 35....406 Brachytherapy sources accountability. (a) A licensee shall maintain accountability at all times... area. (c) A licensee shall maintain a record of the brachytherapy source accountability in accordance...

  15. 10 CFR 35.2406 - Records of brachytherapy source accountability.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of brachytherapy source accountability. 35.2406... Records of brachytherapy source accountability. (a) A licensee shall maintain a record of brachytherapy source accountability required by § 35.406 for 3 years. (b) For temporary implants, the record must...

  16. Procedures for calibration of brachytherapy sources

    International Nuclear Information System (INIS)

    Alfonso Laguardia, R.; Alonso Samper, J.L.; Morales Lopez, J.L.; Saez Nunez, D.G.

    1997-01-01

    Brachytherapy source strength verification is a responsibility of the user of these source, in fact of the Medical Physicists in charge of this issue in a Radiotherapy Service. The calibration procedures in the users conditions are shown. Specifics methods for source strength determination are recommended, both for High Dose Rate (HDR) sources with Remote Afterloading equipment and for Low Dose Rate sources. The The results of the calibration of HDR Remote After loaders are indicated

  17. Iridium-192 sources production for brachytherapy use

    International Nuclear Information System (INIS)

    Rostelato, Maria Elisa Chuery Martins

    1997-01-01

    The incidence of cancer increases every year in Brazil and turns out to be one of the most important causes of mortality. Some of the patients are treated with brachytherapy, a form of lesion treatment which is based on the insertion of sources into tumors, in this particular case, activated iridium wires. During this process, the ionizing radiation efficiently destroys the malignant cells. These iridium wires have a nucleus made out of an iridium-platinum alloy 20-30/70-80 of 0,1 mm in diameter either coated by platinum or encased in a platinum tube. The technique consists in irradiating the wire in the reactor neutron flux in order to produce iridium-192. The linear activity goes from 1 mCi/cm to 4 mCi/cm and the basic characteristic, which is required, is the homogeneity of the activation along the wire. It should not present a dispersion exceeding 5% on a wire measuring 50 cm in length, 0.5 mm or 0.3 mm in diameter. Several experiments were carried out in order to define the activation parameters. Wires from different origins were analyzed. It was concluded that United States of America and France wires were found to be perfectly adequate for brachytherapy purposes and have therefore been sent to specialized hospitals and successfully applied to cancer patients. Considering that the major purpose of this work is to make this product more accessible in Brazil, at a cost reflecting the Brazilian reality, the IPEN is promoting the preparation of iridium-192 sources to be used in brachytherapy, on a national level. (author)

  18. The needs for brachytherapy source calibrations in the United States

    International Nuclear Information System (INIS)

    Coursey, B.M.; Goodman, L.J.; Hoppes, D.D.; Loevinger, R.; McLaughlin, W.L.; Soares, C.G.; Weaver, J.T.

    1992-01-01

    Brachytherapy sources of beta and gamma radiation ('brachy' is from the Greek, meaning 'near') have a long history of use in interstitial, intracavitary, intraluminal, and ocular radiation therapy. In the past the US national standards for these sources were often specified in activity or milligram radium equivalent. With the introduction of new radionuclide sources to replace radium, source strength calibrations are now expressed as air kerma rate at a meter. In this paper, we review the NIST standards for brachytherapy sources, list some of the common radionuclides and source encapsulations in use in the US radiology community, and describe the latest NIST work, in collaboration with several US medical institutions, on a method of two- and three-dimensional dose mapping of brachytherapy sources using radiochromic films. (orig.)

  19. International Standardization of the Clinical Dosimetry of Beta Radiation Brachytherapy Sources: Progress of an ISO Standard

    Science.gov (United States)

    Soares, Christopher

    2006-03-01

    In 2004 a new work item proposal (NWIP) was accepted by the International Organization for Standardization (ISO) Technical Committee 85 (TC85 -- Nuclear Energy), Subcommittee 2 (Radiation Protection) for the development of a standard for the clinical dosimetry of beta radiation sources used for brachytherapy. To develop this standard, a new Working Group (WG 22 - Ionizing Radiation Dosimetry and Protocols in Medical Applications) was formed. The standard is based on the work of an ad-hoc working group initiated by the Dosimetry task group of the Deutsches Insitiut für Normung (DIN). Initially the work was geared mainly towards the needs of intravascular brachytherapy, but with the decline of this application, more focus has been placed on the challenges of accurate dosimetry for the concave eye plaques used to treat ocular melanoma. Guidance is given for dosimetry formalisms, reference data to be used, calibrations, measurement methods, modeling, uncertainty determinations, treatment planning and reporting, and clinical quality control. The document is currently undergoing review by the ISO member bodies for acceptance as a Committee Draft (CD) with publication of the final standard expected by 2007. There are opportunities for other ISO standards for medical dosimetry within the framework of WG22.

  20. Primary calibration of coiled 103Pd brachytherapy sources

    International Nuclear Information System (INIS)

    Paxton, Adam B.; Culberson, Wesley S.; DeWerd, Larry A.; Micka, John A.

    2008-01-01

    Coiled 103 Pd brachytherapy sources have been developed by RadioMed Corporation for use as low-dose-rate (LDR) interstitial implants. The coiled sources are provided in integer lengths from 1 to 6 cm and address many common issues seen with traditional LDR brachytherapy sources. The current standard for determining the air-kerma strength (S K ) of low-energy LDR brachytherapy sources is the National Institute of Standards and Technology's Wide-Angle Free-Air Chamber (NIST WAFAC). Due to geometric limitations, however, the NIST WAFAC is unable to determine the S K of sources longer than 1 cm. This project utilized the University of Wisconsin's Variable-Aperture Free-Air Chamber (UW VAFAC) to determine the S K of the longer coiled sources. The UW VAFAC has shown agreement in S K values of 1 cm length coils to within 1% of those determined with the NIST WAFAC, but the UW VAFAC does not share the same geometric limitations as the NIST WAFAC. A new source holder was constructed to hold the coiled sources in place during measurements with the UW VAFAC. Correction factors for the increased length of the sources have been determined and applied to the measurements. Using the new source holder and corrections, the S K of 3 and 6 cm coiled sources has been determined. Corrected UW VAFAC data and ionization current measurements from well chambers have been used to determine calibration coefficients for use in the measurement of 3 and 6 cm coiled sources in well chambers. Thus, the UW VAFAC has provided the first transferable, primary measurement of low-energy LDR brachytherapy sources with lengths greater than 1 cm

  1. Study of two different radioactive sources for prostate brachytherapy treatment

    International Nuclear Information System (INIS)

    Pereira Neves, Lucio; Perini, Ana Paula; Souza Santos, William de; Caldas, Linda V.E.; Belinato, Walmir

    2015-01-01

    In this study we evaluated two radioactive sources for brachytherapy treatments. Our main goal was to quantify the absorbed doses on organs and tissues of an adult male patient, submitted to a brachytherapy treatment with two radioactive sources. We evaluated a 192 Ir and a 125 I radioactive sources. The 192 Ir radioactive source is a cylinder with 0.09 cm in diameter and 0.415 cm long. The 125 I radioactive source is also a cylinder, with 0.08 cm in diameter and 0.45 cm long. To evaluate the absorbed dose distribution on the prostate, and other organs and tissues of an adult man, a male virtual anthropomorphic phantom MASH, coupled in the radiation transport code MCNPX 2.7.0, was employed.We simulated 75, 90 and 102 radioactive sources of 125 I and one of 192 Ir, inside the prostate, as normally used in these treatments, and each treatment was simulated separately. As this phantom was developed in a supine position, the displacement of the internal organs of the chest, compression of the lungs and reduction of the sagittal diameter were all taken into account. For the 192 Ir, the higher doses values were obtained for the prostate and surrounding organs, as the colon, gonads and bladder. Considering the 125 I sources, with photons with lower energies, the doses to organs that are far from the prostate were lower. All values for the dose rates are in agreement with those recommended for brachytherapy treatments. Besides that, the new seeds evaluated in this work present usefulness as a new tool in prostate brachytherapy treatments, and the methodology employed in this work may be applied for other radiation sources, or treatments. (authors)

  2. Study of two different radioactive sources for prostate brachytherapy treatment

    Energy Technology Data Exchange (ETDEWEB)

    Pereira Neves, Lucio; Perini, Ana Paula [Instituto de Fisica, Universidade Federal de Uberlandia, Caixa Postal 593, 38400-902, Uberlandia, MG (Brazil); Souza Santos, William de; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, IPENCNEN/SP, Av. Prof. Lineu Prestes, 2242, Cidade Universitaria, 05508-000 Sao Paulo, SP (Brazil); Belinato, Walmir [Departamento de Ensino, Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia, Campus Vitoria da Conquista, Zabele, Av. Amazonas 3150, 45030-220 Vitoria da Conquista, BA (Brazil)

    2015-07-01

    In this study we evaluated two radioactive sources for brachytherapy treatments. Our main goal was to quantify the absorbed doses on organs and tissues of an adult male patient, submitted to a brachytherapy treatment with two radioactive sources. We evaluated a {sup 192}Ir and a {sup 125}I radioactive sources. The {sup 192}Ir radioactive source is a cylinder with 0.09 cm in diameter and 0.415 cm long. The {sup 125}I radioactive source is also a cylinder, with 0.08 cm in diameter and 0.45 cm long. To evaluate the absorbed dose distribution on the prostate, and other organs and tissues of an adult man, a male virtual anthropomorphic phantom MASH, coupled in the radiation transport code MCNPX 2.7.0, was employed.We simulated 75, 90 and 102 radioactive sources of {sup 125}I and one of {sup 192}Ir, inside the prostate, as normally used in these treatments, and each treatment was simulated separately. As this phantom was developed in a supine position, the displacement of the internal organs of the chest, compression of the lungs and reduction of the sagittal diameter were all taken into account. For the {sup 192}Ir, the higher doses values were obtained for the prostate and surrounding organs, as the colon, gonads and bladder. Considering the {sup 125}I sources, with photons with lower energies, the doses to organs that are far from the prostate were lower. All values for the dose rates are in agreement with those recommended for brachytherapy treatments. Besides that, the new seeds evaluated in this work present usefulness as a new tool in prostate brachytherapy treatments, and the methodology employed in this work may be applied for other radiation sources, or treatments. (authors)

  3. Determining profile of dose distribution for PD-103 brachytherapy source

    International Nuclear Information System (INIS)

    Berkay, Camgoz; Mehmet, N. Kumru; Gultekin, Yegin

    2006-01-01

    Full text: Brachytherapy is a particular radiotherapy for cancer treatments. By destructing cancerous cells using radiation, the treatment proceeded. When alive tissues are subject it is hazardous to study experimental. For brachytherapy sources generally are studied as theoretical using computer simulation. General concept of the treatment is to locate the radioactive source into cancerous area of related tissue. In computer studies Monte Carlo mathematical method that is in principle based on random number generations, is used. Palladium radioisotope is LDR (Low radiation Dose Rate) source. Main radioactive material was coated with titanium cylinder with 3mm length, 0.25 mm radius. There are two parts of Pd-103 in the titanium cylinder. It is impossible to investigate differential effects come from two part as experimental. Because the source dimensions are small compared with measurement distances. So there is only simulation method. In dosimetric studies it is aimed to determine absorbed dose distribution in tissue as radial and angular. In nuclear physics it is obligation to use computer based methods for researchers. Radiation studies have hazards for scientist and people interacted with radiation. When hazard exceed over recommended limits or physical conditions are not suitable (long work time, non economical experiments, inadequate sensitivity of materials etc.) it is unavoidable to simulate works and experiments before practices of scientific methods in life. In medical area, usage of radiation is required computational work for cancer treatments. Some computational studies are routine in clinics and other studies have scientific development purposes. In brachytherapy studies there are significant differences between experimental measurements and theoretical (computer based) output data. Errors of data taken from experimental studies are larger than simulation values errors. In design of a new brachytherapy source it is important to consider detailed

  4. Evaluation of (101)Rh as a brachytherapy source.

    Science.gov (United States)

    Pakravan, Delaram; Ghorbani, Mahdi; Meigooni, Ali Soleimani

    2015-04-01

    Recently a number of hypothetical sources have been proposed and evaluated for use in brachytherapy. In the present study, a hypothetical (101)Rh source with mean photon energy of 121.5 keV and half-life of 3.3 years, has been evaluated as an alternative to the existing high-dose-rate (HDR) sources. Dosimetric characteristics of this source model have been determined following the recommendation of the Task Group 43 (TG-43) of the American Association of the Physicist in Medicine (AAPM), and the results are compared with the published data for (57)Co source and Flexisource (192)Ir sources with similar geometries. MCNPX Monte Carlo code was used for simulation of the (101)Rh hypothetical HDR source design. Geometric design of this hypothetical source was considered to be similar to that of Flexisource (192)Ir source. Task group No. 43 dosimetric parameters, including air kerma strength per mCi, dose rate constant, radial dose function, and two dimensional (2D) anisotropy functions were calculated for the (101)Rh source through simulations. Air kerma strength per activity and dose rate constant for the hypothetical (101)Rh source were 1.09 ± 0.01 U/mCi and 1.18 ± 0.08 cGy/(h.U), respectively. At distances beyond 1.0 cm in phantom, radial dose function for the hypothetical (101)Rh source is higher than that of (192)Ir. It has also similar 2D anisotropy functions to the Flexisource (192)Ir source. (101)Rh is proposed as an alternative to the existing HDR sources for use in brachytherapy. This source provides medium energy photons, relatively long half-life, higher dose rate constant and radial dose function, and similar 2D anisotropy function to the Flexisource (192)Ir HDR source design. The longer half-life of the source reduces the frequency of the source exchange for the clinical environment.

  5. Evaluation of hypothetical (153)Gd source for use in brachytherapy.

    Science.gov (United States)

    Ghorbani, Mahdi; Behmadi, Marziyeh

    2016-01-01

    The purpose of this work is to evaluate the dosimetric parameters of a hypothetical (153)Gd source for use in brachytherapy and comparison of the dosimetric parameters with those of (192)Ir and (125)I sources. Dose rate constant, the radial dose function and the two dimensional (2D) anisotropy function data for the hypothetical (153)Gd source were obtained by simulation of the source using MCNPX code and then were compared with the corresponding data reported by Enger et al. A comprehensive comparison between this hypothetical source and a (192)Ir source with similar geometry and a (125)I source was performed as well. Excellent agreement was shown between the results of the two studies. Dose rate constant values for the hypothetical (153)Gd, (192)Ir, (125)I sources are 1.173 cGyh(-1) U(-1), 1.044 cGyh(-1) U(-1), 0.925 cGyh(-1) U(-1), respectively. Radial dose function for the hypothetical (153)Gd source has an increasing trend, while (192)Ir has more uniform and (125)I has more rapidly falling off radial dose functions. 2D anisotropy functions for these three sources indicate that, except at 0.5 cm distance, (192)Ir and (125)I have more isotropic trends as compared to the (153)Gd source. A more uniform radial dose function, and 2D anisotropy functions with more isotropy, a much higher specific activity are advantages of (192)Ir source over (153)Gd. However, a longer half-life of (153)Gd source compared to the other two sources, and lower energy of the source with respect to (192)Ir are advantages of using (153)Gd in brachytherapy versus (192)Ir source.

  6. Cs-137 brachytherapy sources calibration with well chamber

    International Nuclear Information System (INIS)

    Brunetto, M.; Sansogne, R.; Arbiser, S.; Duran, M.P.

    2004-01-01

    This work describes the procedures and actions developed for the identification and reference air kerma rate (S k ) verification of Cs-137 sources used in gynecological brachytherapy practices. Following the IAEA TECDOC 1151 recommendations, the first stage consisted in designing the documentation required for the inventory and shipping registry of sources, along with the digital spreadsheets for calculating the decay and S k of the sources at the moment of implantation. As a second stage, the S k of sources was measured, following the low dose rate sources protocol advise, with a Standard Imaging HDR 1000 Plus well chamber calibrated at the University of Wisconsin SSDL. The documentation generated through this procedure allows identify each source clearly and uni-vocally. No significant differences were found between the S k values obtained from the well chamber calibration procedure and those reported by the manufacturer in the corresponding certificates. The highest percent difference found was 2.3%. (author) [es

  7. Three-dimensional tomosynthetic image restoration for brachytherapy source localization

    International Nuclear Information System (INIS)

    Persons, Timothy M.

    2001-01-01

    Tomosynthetic image reconstruction allows for the production of a virtually infinite number of slices from a finite number of projection views of a subject. If the reconstructed image volume is viewed in toto, and the three-dimensional (3D) impulse response is accurately known, then it is possible to solve the inverse problem (deconvolution) using canonical image restoration methods (such as Wiener filtering or solution by conjugate gradient least squares iteration) by extension to three dimensions in either the spatial or the frequency domains. This dissertation presents modified direct and iterative restoration methods for solving the inverse tomosynthetic imaging problem in 3D. The significant blur artifact that is common to tomosynthetic reconstructions is deconvolved by solving for the entire 3D image at once. The 3D impulse response is computed analytically using a fiducial reference schema as realized in a robust, self-calibrating solution to generalized tomosynthesis. 3D modulation transfer function analysis is used to characterize the tomosynthetic resolution of the 3D reconstructions. The relevant clinical application of these methods is 3D imaging for brachytherapy source localization. Conventional localization schemes for brachytherapy implants using orthogonal or stereoscopic projection radiographs suffer from scaling distortions and poor visibility of implanted seeds, resulting in compromised source tracking (reported errors: 2-4 mm) and dosimetric inaccuracy. 3D image reconstruction (using a well-chosen projection sampling scheme) and restoration of a prostate brachytherapy phantom is used for testing. The approaches presented in this work localize source centroids with submillimeter error in two Cartesian dimensions and just over one millimeter error in the third

  8. Monte Carlo Simulations Validation Study: Vascular Brachytherapy Beta Sources

    International Nuclear Information System (INIS)

    Orion, I.; Koren, K.

    2004-01-01

    During the last decade many versions of angioplasty irradiation treatments have been proposed. The purpose of this unique brachytherapy is to administer a sufficient radiation dose into the vein walls in order to prevent restonosis, a clinical sequel to balloon angioplasty. The most suitable sources for this vascular brachytherapy are the β - emitters such as Re-188, P-32, and Sr-90/Y-90, with a maximum energy range of up to 2.1 MeV [1,2,3]. The radioactive catheters configurations offered for these treatments can be a simple wire [4], a fluid filled balloon or a coated stent. Each source is differently positioned inside the blood vessel, and the emitted electrons ranges therefore vary. Many types of sources and configurations were studied either experimentally or with the use of the Monte Carlo calculation technique, while most of the Monte Carlo simulations were carried out using EGS4 [5] or MCNP [6]. In this study we compared the beta-source absorbed-dose versus radial-distance of two treatment configurations using MCNP and EGS4 simulations. This comparison was aimed to discover the differences between the MCNP and the EGS4 simulation code systems in intermediate energies electron transport

  9. Calibration of brachytherapy sources. Guidelines on standardized procedures for the calibration of brachytherapy sources at Secondary Standard Dosimetry Laboratories (SSDLs) and hospitals

    International Nuclear Information System (INIS)

    1999-04-01

    Today, irradiation by brachytherapy is considered an essential part of the treatment for almost all the sites of cancer. With the improved localization techniques and treatment planning systems, it is now possible to have precise and reproducible dose delivery. However, the desired clinical results can only be achieved with a good clinical and dosimetric practice, i.e. with the implementation of a comprehensive quality assurance (QA) programme which includes detailed quality control procedures. As summarized in the present report, accidents in brachytherapy treatments have been caused due to the lack of traceable calibration of the sources, due to the incorrect use of quantities and units, or errors made in the dose calculation procedure. The International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources has established a requirement on the calibration of sources used for medical exposure. For sources used in brachytherapy treatments, a calibration traceable to a standards dosimetry laboratory is required. The present report deals with the calibration of brachytherapy sources and related quality control (QC) measurements, QC of ionization chambers and safety aspects related to the calibration procedures. It does not include safety aspects related to the clinical use of brachytherapy sources, which have been addressed in a recent IAEA publication, IAEA-TECDOC-1040, 'Design and Implementation of a Radiotherapy Programme: Clinical, Medical Physics, Radiation Protection and Safety Aspects'. The procedures recommended in this report yield traceability to internationally accepted standards. It must be realized, however, that a comprehensive QA programme for brachytherapy cannot rest on source calibration alone, but must ensure QC of all the equipment and techniques that are used for the dose delivery to the patient. The present publication incorporates the reports of several consultants meetings in the field of

  10. Evaluation of 101Rh as a brachytherapy source

    Science.gov (United States)

    Ghorbani, Mahdi; Meigooni, Ali Soleimani

    2015-01-01

    Purpose Recently a number of hypothetical sources have been proposed and evaluated for use in brachytherapy. In the present study, a hypothetical 101Rh source with mean photon energy of 121.5 keV and half-life of 3.3 years, has been evaluated as an alternative to the existing high-dose-rate (HDR) sources. Dosimetric characteristics of this source model have been determined following the recommendation of the Task Group 43 (TG-43) of the American Association of the Physicist in Medicine (AAPM), and the results are compared with the published data for 57Co source and Flexisource 192Ir sources with similar geometries. Material and methods MCNPX Monte Carlo code was used for simulation of the 101Rh hypothetical HDR source design. Geometric design of this hypothetical source was considered to be similar to that of Flexisource 192Ir source. Task group No. 43 dosimetric parameters, including air kerma strength per mCi, dose rate constant, radial dose function, and two dimensional (2D) anisotropy functions were calculated for the 101Rh source through simulations. Results Air kerma strength per activity and dose rate constant for the hypothetical 101Rh source were 1.09 ± 0.01 U/mCi and 1.18 ± 0.08 cGy/(h.U), respectively. At distances beyond 1.0 cm in phantom, radial dose function for the hypothetical 101Rh source is higher than that of 192Ir. It has also similar 2D anisotropy functions to the Flexisource 192Ir source. Conclusions 101Rh is proposed as an alternative to the existing HDR sources for use in brachytherapy. This source provides medium energy photons, relatively long half-life, higher dose rate constant and radial dose function, and similar 2D anisotropy function to the Flexisource 192Ir HDR source design. The longer half-life of the source reduces the frequency of the source exchange for the clinical environment. PMID:26034499

  11. Modeling a Hypothetical 170Tm Source for Brachytherapy Applications

    International Nuclear Information System (INIS)

    Enger, Shirin A.; D'Amours, Michel; Beaulieu, Luc

    2011-01-01

    Purpose: To perform absorbed dose calculations based on Monte Carlo simulations for a hypothetical 170 Tm source and to investigate the influence of encapsulating material on the energy spectrum of the emitted electrons and photons. Methods: GEANT4 Monte Carlo code version 9.2 patch 2 was used to simulate the decay process of 170 Tm and to calculate the absorbed dose distribution using the GEANT4 Penelope physics models. A hypothetical 170 Tm source based on the Flexisource brachytherapy design with the active core set as a pure thulium cylinder (length 3.5 mm and diameter 0.6 mm) and different cylindrical source encapsulations (length 5 mm and thickness 0.125 mm) constructed of titanium, stainless-steel, gold, or platinum were simulated. The radial dose function for the line source approximation was calculated following the TG-43U1 formalism for the stainless-steel encapsulation. Results: For the titanium and stainless-steel encapsulation, 94% of the total bremsstrahlung is produced inside the core, 4.8 and 5.5% in titanium and stainless-steel capsules, respectively, and less than 1% in water. For the gold capsule, 85% is produced inside the core, 14.2% inside the gold capsule, and a negligible amount ( 170 Tm source is primarily a bremsstrahlung source, with the majority of bremsstrahlung photons being generated in the source core and experiencing little attenuation in the source encapsulation. Electrons are efficiently absorbed by the gold and platinum encapsulations. However, for the stainless-steel capsule (or other lower Z encapsulations) electrons will escape. The dose from these electrons is dominant over the photon dose in the first few millimeter but is not taken into account by current standard treatment planning systems. The total energy spectrum of photons emerging from the source depends on the encapsulation composition and results in mean photon energies well above 100 keV. This is higher than the main gamma-ray energy peak at 84 keV. Based on our

  12. Brachytherapy with 125-Iodine sources: transport and radiation protection

    International Nuclear Information System (INIS)

    Souza, Carla D.; Zeituni, Carlos A.; Moura, Joao A.; Moura, Eduardo S.; Nagatomi, Helio R.; Feher, Anselmo; Hilario, Katia F.; Rostelato, Maria Elisa C.M.

    2009-01-01

    The estimates for the year 2009 show that 466,730 new cancer cases will occur in Brazil. Prostate cancer is the second most incident type. Brachytherapy, a type of radiotherapy, with Iodine-125 sources are an important form of treatment for this kind of cancer. The Instituto de Pesquisas Energeticas e Nucleares (IPEN) created a project to develop a national prototype of these sources and is implementing a facility for local production. The seeds manufacture in Brazil will allow to diminish the treatment cost and make it possible for a larger number of patients. While the laboratory is not ready, the IPEN import and it distributes seeds. This work aim is to present and evaluate the transport procedures and the radiological protection applied to imported sources in order to assist the procedures for the new laboratory implementation. Before sending to hospitals, the seeds are packed by a radioprotector supervisor, in accordance with CNEN NE 5.01 standard 'Radioactive Material Transport'. Despite Iodine-125 presents low energy photons, around 29 keV, local and personal dosimeters are used during the transport process, as described in CNEN NN 3.01 standard 'Radiological Protection Basic Guideline'. All the results show no contamination and very low exposure, proving the method to be valid. The transport procedure used is correct, according to the regulations. As an result of this work, a new dosimeter should be installed and evaluate in future study. (author)

  13. Quality assurance of Vari-source high dose rate (HDR) brachytherapy- remote after loader and cost effectiveness of Vari-source HDR- brachytherapy: NORI, Islamabad experience

    International Nuclear Information System (INIS)

    Ahmad, N.; Mahmood, H.; Jafri, S.R.A.

    2004-01-01

    A quality control of Vari-Source high dose rate (HDR) remote after loading brachytherapy machine was carried out and the cost effectiveness of HDR brachytherapy machine was also evaluated considering the cost of ten Iridium-192 wire sources at Nuclear Medicine, Oncology and Radiotherapy Institute (NORI), Islamabad, Pakistan. A total number of 253 intracavitary insertions were done in 98 patients from October 1996 to May 2001. The results of the quality control tests performed during 1996 to 2001 were within the acceptable limits. The cost effectiveness of Vari-Source HDR brachytherapy machine was also evaluated. The average cost per patient was calculated as US$ 491. Small number of patients was treated as the machine was used for gynecologic malignancies only. The objective was to assess the quality control status of HDR brachytherapy machine on patient treatment day, source exchange day and periodic day (monthly basis). It was found that the cost per patient can be minimized if other type of cancer patients are also treated on Vari-Source HDR machine. (author)

  14. Prototypes of phosphorus-32 sealed sources for use in Brachytherapy

    International Nuclear Information System (INIS)

    Anaya Garro, Olgger; Vela Mora, Mariano; Revilla Silva, Angel Revilla

    2005-01-01

    It has developed prototypes of phosphorus-32 sealed sources for use in Brachytherapy. This one was made in two stages, at the first one, we designed and constructed the container (capsule), the filling system and the sealed system; at the second one, we made the irradiation of the capsules containing the 'target'. The prototypes was made of aluminum in cylindrical geometry. During the irradiation test was made using two different dimensions: one of 1 mm outer diameter and 1 cm length and another one of 0.8 mm outer diameter and 5 mm length. They were radiated in the core of the RP-10 research reactor, at 7.93 x10 13 n/cm 2 .s thermal neutron flux during 27 operation cycles. Activities of 144.53 MBq (3.91 mCi) and 107.67 MBq (2.91 mCi) was obtained for each case. This activities are adequate to restenosis and for some tumors treatment. We can observed that the capsules irradiated passed visual inspection in its physical integrity (leakage and geometry). It has been demonstrated, that the beta radiation for his minor power of penetration and its high interaction, causes major local damage to the malignant tissue, minimizing the damage of the healthy surrounding tissues. It has been advisable to use for the treatment of illnesses of the circulatory system and some tumors. At the present, the source of strontium-90 are the most beta ray source used, but of this one are obtained as fission product of uranium target, where valuable radioactive waste is generated, whereas if we were using phosphorus-32 that we propose, radioactive waste would not be generated since it would take place directly as sealed source, for reaction (n, β). (author)

  15. Guidelines for the calibration of low energy photon sources at beta-ray brachytherapy sources

    International Nuclear Information System (INIS)

    2000-01-01

    With the development of improved methods of implanting brachytherapy sources in a precise manner for treating prostate cancer and other disease processes, there has been a tremendous growth in the use of low energy photon sources, such as 125 I and 103 Pd brachytherapy seeds. Low energy photon sources have the advantage of easier shielding and also lowering the dose to normal tissue. However, the dose distributions around these sources are affected by the details in construction of the source and its encapsulation more than other sources used for brachytherapy treatments, such as 192 Ir. With increasing number of new low energy photon sources on the market, care should be taken with regard to its traceability to primary standards. It cannot be assumed that a calibration factor for an ionization chamber that is valid for one type of low energy photon source, automatically is valid for another source even if both would use the same isotope. Moreover, the method used to calculate the dose must also take into account the structure of the source and the encapsulation. The dose calculation algorithm that is valid for one type of low energy source may not be valid for another source even if in both cases the same radionuclide is used. Simple ''point source'' approximations, i.e. where the source is modeled as a point, should be avoided, as such methods do not account for any details in the source construction. In this document, the dose calculation formalism adopted for low energy photon sources is that recommended by the American Association of Physicists in Medicine (AAPM) as outlined by Task Group-43 (TG-43). This method accounts for the source and capsule geometry. The AAPM recommends brachytherapy photon sources to be specified in terms of 'Air Kerma Strength' that is also used in the formalism mentioned above. On the other hand, the International Commission on Radiation Units and Measurements (ICRU) recommends that the specification be done in terms of Reference Air

  16. Production of 125I seed sources for brachytherapy uses

    International Nuclear Information System (INIS)

    Benites, M.; Miranda, J.; Condor, R.; Cavero, L.; Martinez, R.

    2006-01-01

    The production of radioactive sources of 125 I, used mainly for the brachytherapy of prostate and ocular cancer, is a work that is being carried out in the plant of production of radioisotopes (PPR) of the Nuclear Center Racso of the IPEN. The employed methodology is based on the 125 I physical-chemistry adsorption at silver wires coated with palladium. In the realization of the tests, it has been considered the procedure used by India and Iran participants of this CRP. In the execution of this work, the 131 I radioisotope is been used simulating the 125 I, because in the PPR-IPEN we produce the 131 I. In total 50 samples were used, they were divided in ten groups. In first place with nine working groups, the optimum conditions for work for the coating of the silver wires with palladium were obtained, these being the following: simple method, employing PdCl 2 0.1 m, pH of 5.5 to 6.5 and a temperature of 100 deg. C. Later on, a series of tests were carried out to determine the appropriate parameters for the adsorption of 131 I in the previously treated wires, these being the following: carrier concentration of Ki 0.03 m, time of adsorption of 6 hours, and temperature of 70 deg. C. Finally, the percentage of 131 I adsorption was obtained in the silver wires tried previously with palladium chloride solution of 98.24%. The control of leachability was made, having very good results. To confirm these previously mentioned parameters, a test was made with ten pieces of silver wires, corresponding to the group 10, giving the confirmation as a result of these. Also, samples of the titanium tube have been sent for test with microplasma welding to a French company: air welding liquidates export. With these results obtained, subsequently the production of these radioactive sources will be carried out employing 125 I as a radioisotope. (author)

  17. Comparison of the hypothetical (57)Co brachytherapy source with the (192)Ir source.

    Science.gov (United States)

    Toossi, Mohammad Taghi Bahreyni; Ghorbani, Mahdi; Rostami, Atefeh; Khosroabadi, Mohsen; Khademi, Sara; Knaup, Courtney

    2016-01-01

    The (57)Co radioisotope has recently been proposed as a hypothetical brachytherapy source due to its high specific activity, appropriate half-life (272 days) and medium energy photons (114.17 keV on average). In this study, Task Group No. 43 dosimetric parameters were calculated and reported for a hypothetical (57)Co source. A hypothetical (57)Co source was simulated in MCNPX, consisting of an active cylinder with 3.5 mm length and 0.6 mm radius encapsulated in a stainless steel capsule. Three photon energies were utilized (136 keV [10.68%], 122 keV [85.60%], 14 keV [9.16%]) for the (57)Co source. Air kerma strength, dose rate constant, radial dose function, anisotropy function, and isodose curves for the source were calculated and compared to the corresponding data for a (192)Ir source. The results are presented as tables and figures. Air kerma strength per 1 mCi activity for the (57)Co source was 0.46 cGyh(-1) cm 2 mCi(-1). The dose rate constant for the (57)Co source was determined to be 1.215 cGyh(-1)U(-1). The radial dose function for the (57)Co source has an increasing trend due to multiple scattering of low energy photons. The anisotropy function for the (57)Co source at various distances from the source is more isotropic than the (192)Ir source. The (57)Co source has advantages over (192)Ir due to its lower energy photons, longer half-life, higher dose rate constant and more isotropic anisotropic function. However, the (192)Ir source has a higher initial air kerma strength and more uniform radial dose function. These properties make (57)Co a suitable source for use in brachytherapy applications.

  18. In vivo dosimetry thermoluminescence dosimeters during brachytherapy with a 370 GBq {sup 192}Ir source

    Energy Technology Data Exchange (ETDEWEB)

    Cuepers, S.; Piessens, M.; Verbeke, L.; Roelstraete, A. [Onze-Lieve-Vrouw Hospitaal, Aalst (Belgium). Dept. of Radiotherapy and Oncology

    1995-12-01

    When using LiF thermoluminescence dosimeters in brachytherapy, we have to take into account the properties of a high dose rate {sup 192}Ir source (energy spectrum ranging form 9 to 885 keV, steep dose gradient in the vicinity of the source) and these of the dosimeters themselves (supralinearity, reproducibility, size). All these characteristics combine into a set of correction factors which have been determined during in phantom measurements. These results have then been used to measure the dose delivered to organs at risk (e.g. rectum, bladder, etc.) during high dose rate brachytherapy with a 370 GBq {sup 192}Ir source for patients with gynaecological tumors.

  19. In vivo dosimetry thermoluminescence dosimeters during brachytherapy with a 370 GBq 192Ir source

    International Nuclear Information System (INIS)

    Cuepers, S.; Piessens, M.; Verbeke, L.; Roelstraete, A.

    1995-01-01

    When using LiF thermoluminescence dosimeters in brachytherapy, we have to take into account the properties of a high dose rate 192 Ir source (energy spectrum ranging form 9 to 885 keV, steep dose gradient in the vicinity of the source) and these of the dosimeters themselves (supralinearity, reproducibility, size). All these characteristics combine into a set of correction factors which have been determined during in phantom measurements. These results have then been used to measure the dose delivered to organs at risk (e.g. rectum, bladder, etc.) during high dose rate brachytherapy with a 370 GBq 192 Ir source for patients with gynaecological tumors

  20. Water equivalency evaluation of PRESAGE® dosimeters for dosimetry of Cs-137 and Ir-192 brachytherapy sources

    Science.gov (United States)

    Gorjiara, Tina; Hill, Robin; Kuncic, Zdenka; Baldock, Clive

    2010-11-01

    A major challenge in brachytherapy dosimetry is the measurement of steep dose gradients. This can be achieved with a high spatial resolution three dimensional (3D) dosimeter. PRESAGE® is a polyurethane based dosimeter which is suitable for 3D dosimetry. Since an ideal dosimeter is radiologically water equivalent, we have investigated the relative dose response of three different PRESAGE® formulations, two with a lower chloride and bromide content than original one, for Cs-137 and Ir-192 brachytherapy sources. Doses were calculated using the EGSnrc Monte Carlo package. Our results indicate that PRESAGE® dosimeters are suitable for relative dose measurement of Cs-137 and Ir-192 brachytherapy sources and the lower halogen content PRESAGE® dosimeters are more water equivalent than the original formulation.

  1. High dose-rate brachytherapy source position quality assurance using radiochromic film

    International Nuclear Information System (INIS)

    Evans, M.D.C.; Devic, S.; Podgorsak, E.B.

    2007-01-01

    Traditionally, radiographic film has been used to verify high-dose-rate brachytherapy source position accuracy by co-registering autoradiographic and diagnostic images of the associated applicator. Filmless PACS-based clinics that do not have access to radiographic film and wet developers may have trouble performing this quality assurance test in a simple and practical manner. We describe an alternative method for quality assurance using radiochromic-type film. In addition to being easy and practical to use, radiochromic film has some advantages in comparison with traditional radiographic film when used for HDR brachytherapy quality assurance

  2. Clinical Practice and Quality Assurance Challenges in Modern Brachytherapy Sources and Dosimetry

    International Nuclear Information System (INIS)

    Butler, Wayne M.; Merrick, Gregory S.

    2008-01-01

    Modern brachytherapy has led to effective treatments through the establishment of broadly applicable dosimetric thresholds for maximizing survival with minimal morbidity. Proper implementation of recent dosimetric consensus statements and quality assurance procedures is necessary to maintain the established level of safety and efficacy. This review classifies issues as either 'systematic' or 'stochastic' in terms of their impact on large groups or individual patients, respectively. Systematic changes affecting large numbers of patients occur infrequently and include changes in source dosimetric parameters, prescribing practice, dose calculation formalism, and improvements in calculation algorithms. The physicist must be aware of how incipient changes accord with previous experience. Stochastic issues involve procedures that are applied to each patient individually. Although ample guidance for quality assurance of brachytherapy sources exists, some ambiguities remain. The latest American Association of Physicists in Medicine guidance clarifies what is meant by independent assay, changes source sampling recommendations, particularly for sources in sterile strands and sterile preassembled needles, and modifies action level thresholds. The changing environment of brachytherapy has not changed the fact that the prime responsibility for quality assurance in brachytherapy lies with the institutional medical physicist

  3. GEC/ESTRO-EAU recommendations on temporary brachytherapy using stepping sources for localised prostate cancer

    NARCIS (Netherlands)

    Kovács, György; Pötter, Richard; Loch, Tillmann; Hammer, Josef; Kolkman-Deurloo, Inger-Karine; de La Rosette, Jean J. M. C. H.; Bertermann, Hagen

    2005-01-01

    Background and purpose: The aim of this paper is to present the GEC/ESTRO-EAU recommendations for template and transrectal ultrasound (TRUS) guided transperineal temporary interstitial prostate brachytherapy using a high dose rate iridium-192 stepping source and a remote afterloading technique.

  4. Evaluation of TG-43 recommended 2D-anisotropy function for elongated brachytherapy sources

    International Nuclear Information System (INIS)

    Awan, Shahid B.; Meigooni, Ali S.; Mokhberiosgouei, Ramin; Hussain, Manzoor

    2006-01-01

    The original and updated protocols recommended by Task Group 43 from the American Association of Physicists in Medicine (i.e., TG-43 and TG-43U1, respectively), have been introduced to unify brachytherapy source dosimetry around the world. Both of these protocols are based on experiences with sources less than 1.0 cm in length. TG-43U1 recommends that for 103 Pd sources, 2D anisotropy function F(r,θ), should be tabulated at a minimum for radial distances of 0.5, 1.0, 2.0, 3.0, and 5.0 cm. Anisotropy functions defined in these protocols are only valid when the point of calculation does not fall on the active length of the source. However, for elongated brachytherapy sources (active length >1 cm), some of the calculation points with r 103 Pd source at radial distances of 2.5, 3.0, and 4.0 cm were 2.95, 1.74, and 1.19, respectively, with differences up to about a factor of 3. Therefore, the validity of the linear interpolation technique for an elongated brachytherapy source with such a large variation in F(r,θ) needs to be investigated. In this project, application of the TG-43U1 formalism for dose calculation around an elongated RadioCoil trade mark sign 103 Pd brachytherapy source has been investigated. In addition, the linear interpolation techniques as described in TG-43U1 for seed type sources have been evaluated for a 5.0 cm long RadioCoil trade mark sign 103 Pd brachytherapy source. Application of a polynomial fit to F(r,θ) has also been investigated as an alternate approach to the linear interpolation technique. The results of these investigations indicate that the TG-43U1 formalism can be extended for elongated brachytherapy sources, if the two-dimensional (2D) anisotropy function is tabulated at a minimum for radial distances of 0.2, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0 cm, L/2, and L/2±0.2 cm. Moreover, with the addition of recommended radial distances for 2D anisotropy functions, the linear interpolation technique more closely replicates

  5. Determination of the tissue inhomogeneity correction in high dose rate Brachytherapy for Iridium-192 source

    Directory of Open Access Journals (Sweden)

    Barlanka Ravikumar

    2012-01-01

    Full Text Available In Brachytherapy treatment planning, the effects of tissue heterogeneities are commonly neglected due to lack of accurate, general and fast three-dimensional (3D dose-computational algorithms. In performing dose calculations, it is assumed that the tumor and surrounding tissues constitute a uniform, homogeneous medium equivalent to water. In the recent past, three-dimensional computed tomography (3D-CT based treatment planning for Brachytherapy applications has been popularly adopted. However, most of the current commercially available planning systems do not provide the heterogeneity corrections for Brachytherapy dosimetry. In the present study, we have measured and quantified the impact of inhomogeneity caused by different tissues with a 0.015 cc ion chamber. Measurements were carried out in wax phantom which was employed to measure the heterogeneity. Iridium-192 (192 Ir source from high dose rate (HDR Brachytherapy machine was used as the radiation source. The reduction of dose due to tissue inhomogeneity was measured as the ratio of dose measured with different types of inhomogeneity (bone, spleen, liver, muscle and lung to dose measured with homogeneous medium for different distances. It was observed that different tissues attenuate differently, with bone tissue showing maximum attenuation value and lung tissue resulting minimum value and rest of the tissues giving values lying in between those of bone and lung. It was also found that inhomogeneity at short distance is considerably more than that at larger distances.

  6. Reference air kerma rate calibration system for high dose rate Ir-192 brachytherapy sources in Taiwan

    Science.gov (United States)

    Chu, Wei-Han; Yuan, Ming-Chen; Lee, Jeng-Hung; Lin, Yi-Chun

    2017-11-01

    Ir-192 sources are widely used in brachytherapy and the number of treatments is around seven thousand for the use of the high dose rate (HDR) Ir-192 brachytherapy source per year in Taiwan. Due to its physical half-life of 73.8 days, the source should be replaced four times per year to maintain the HDR treatment mode (DDEP, 2005; Coursey et al., 1992). When doing this work, it must perform the source dose trace to assure the dose accuracy. To establish the primary measurement standard of reference air kerma rate(RAKR) for the HDR Ir-192 brachytherapy sources in Taiwan, the Institute of Nuclear Energy Research (INER) fabricated a dual spherical graphite-walled cavity ionization chambers system to directly measure the RAKR of the Ir-192 brachytherapy source. In this system, the ion-charge was accumulated by the two ionization chambers and after correction for the ion recombination, temperature, atmosphere pressure, room scattering, graphite-wall attenuation, air attenuation, source decay, stem effect, and so on. The RAKR of the Ir-192 source was obtained in the ambient conditions of 22 °C and one atmosphere. The measurement uncertainty of the system was around 0.92% in 96% confidence level (k=2.0). To verify the accuracy of the result, the source calibration comparison has been made at the National Radiation Standard Laboratory (NRSL) of INER and Physikalisch-Technische Bundesanstalt (PTB, Germany) in 2015. The ratio of the measurement results between INER and PTB, INER/PTB, was 0.998±0.027 (k=2) which showed good consistency and the performance of the system was verified.

  7. Tracking brachytherapy sources using emission imaging with one flat panel detector

    International Nuclear Information System (INIS)

    Song Haijun; Bowsher, James; Das, Shiva; Yin Fangfang

    2009-01-01

    This work proposes to use the radiation from brachytherapy sources to track their dwell positions in three-dimensional (3D) space. The prototype device uses a single flat panel detector and a BB tray. The BBs are arranged in a defined pattern. The shadow of the BBs on the flat panel is analyzed to derive the 3D coordinates of the illumination source, i.e., the dwell position of the brachytherapy source. A kilovoltage x-ray source located 3.3 m away was used to align the center BB with the center pixel on the flat panel detector. For a test plan of 11 dwell positions, with an Ir-192 high dose rate unit, one projection was taken for each dwell point, and locations of the BB shadows were manually identified on the projection images. The 3D coordinates for the 11 dwell positions were reconstructed based on two BBs. The distances between dwell points were compared with the expected values. The average difference was 0.07 cm with a standard deviation of 0.15 cm. With automated BB shadow recognition in the future, this technique possesses the potential of tracking the 3D trajectory and the dwell times of a brachytherapy source in real time, enabling real time source position verification.

  8. Dosimetry experience of 192IR sources used In HDR brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Daci, Lulzime; Myrku, Rodina Cela

    2013-01-01

    Purpose/Objective: The 192IR Sources are the most commonly used in radiotherapy treatments HDR worldwide. According to international recommendations on quality assurance in HDR brachytherapy, an acceptance test based on the determination of the source strength of any new source shall be carried out before first application to verify the manufacturer’s calibration data. The present paper gives the experimental determination of the source strength for our brachytherapy sources used until now in brachytherapy treatments. Materials/Methods: At Mother Teresa University Hospital we have a cost-effective gynecological brachytherapy unit from Eckert & Ziegler BEBIG named GyneSource® that is a five channel HDR after loader equipped with an 192IR source. The software used is HDR plus™ 2.5 that delivers an optimized treatment plan and makes the process especially fast and we use intracavitary BEBIG applicators. From April 2009 up to December 2012, we have imported nine HDR 192IR Sources. The exchange of the source and acceptance test is done by the physicist of the clinic once the source is imported. The measurements are done with a Well-type ionization chamber HDR1000 Plus and the electrometer used is MAX4000. Only seven sources are compared as we miss the dosimetry data of the first source, and the forth source was not measured and not used because the machine was not working in that time. Results/Conclusions: Eight sources were accepted for clinically use as the measurement were within the tolerance. The source number four with e deviation of -1.92% has been double checked compared with a free in-air measurement with farmer type chamber that gave a deviation to source certificate of 4% that is still inside the tolerance to accept a source for clinical use. The deviations of measured Air Kerma rate to the value of the sources certificates of all our used 192IR sources are less than 2%, which are within the tolerance. The checked value of updated source strength in

  9. Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source

    International Nuclear Information System (INIS)

    Sarabiasl, Akbar; Ayoobian, Navid; Jabbari, Iraj; Poorbaygi, Hossein; Javanshir, Mohammad Reza

    2016-01-01

    High-dose-rate (HDR) brachytherapy is a common method for cancer treatment in clinical brachytherapy. Because of the different source designs, there is a need for specific dosimetry data set for each HDR model. The purpose of this study is to obtain detailed dose rate distributions in water phantom for a first prototype HDR 192 Ir brachytherapy source model, IRAsource, and compare with the other published works. In this study, Monte Carlo N-particle (MCNP version 4C) code was used to simulate the dose rate distributions around the HDR source. A full set of dosimetry parameters reported by the American Association of Physicists in Medicine Task Group No. 43U1 was evaluated. Also, the absorbed dose rate distributions in water, were obtained in an along-away look-up table. The dose rate constant, Λ, of the IRAsource was evaluated to be equal to 1.112 ± 0.005 cGy h −1 U −1 . The results of dosimetry parameters are presented in tabulated and graphical formats and compared with those reported from other commercially available HDR 192 Ir sources, which are in good agreement. This justifies the use of specific data sets for this new source. The results obtained in this study can be used as input data in the conventional treatment planning systems.

  10. The need for international standardization in clinical beta dosimetry for brachytherapy

    International Nuclear Information System (INIS)

    Quast, U.; Boehm, J.; Kaulich, T.W.

    2002-01-01

    Beta radiation has found increasing interest in radiotherapy. Besides the curative treatment of small and medium-sized intraocular tumors by means of ophthalmic beta radiation plaques, intravascular brachytherapy has proven to successfully overcome the severe problem of restenosis after interventional treatment of arterial stenosis in coronaries and peripheral vessels in many clinical trials with a large number of patients. Prior to initiating procedures applying beta radiation in radiotherapy, however, there is a common need to specify methods for the determination and specification of the absorbed dose to water or tissue and their spatial distributions. The IAEA-TECDOC-1274 Calibration of photon and beta ray sources used in brachytherapy (2002) is a help for photon brachytherapy calibration. But, for beta seed and line sources, IAEA recommends well type ionization chambers as working standards which are far from measuring absorbed dose to water of the radiation clinically used. Although the application of such working standards seems to be more precise, large errors can occur when the medical physicist has to convert the calibration data to absorbed dose to water of the beta radiation emitted. The user must believe that the source is equally activated and that the manufacturer did not change the design and construction of the source encapsulation. With the DGMP Report 16 (2001) Guidelines for medical physical aspects of intravascular brachytherapy a very detailed code of practice is given, especially for the calibration and clinical dosimetry of intravascular beta radiation sources. As there is a global need for standardization in clinical dosimetry for intravascular brachytherapy utilizing beta radiation, the DIN-NAR, the German committee on standardization in radiology, task group dosimetry, has initiated an international adhoc working group for a new ISO work item proposal on the standardization of procedures in clinical dosimetry to guarantee reliable

  11. Source position verification and dosimetry in HDR brachytherapy using an EPID

    International Nuclear Information System (INIS)

    Smith, R. L.; Taylor, M. L.; McDermott, L. N.; Franich, R. D.; Haworth, A.; Millar, J. L.

    2013-01-01

    Purpose: Accurate treatment delivery in high dose rate (HDR) brachytherapy requires correct source dwell positions and dwell times to be administered relative to each other and to the surrounding anatomy. Treatment delivery inaccuracies predominantly occur for two reasons: (i) anatomical movement or (ii) as a result of human errors that are usually related to incorrect implementation of the planned treatment. Electronic portal imaging devices (EPIDs) were originally developed for patient position verification in external beam radiotherapy and their application has been extended to provide dosimetric information. The authors have characterized the response of an EPID for use with an 192 Ir brachytherapy source to demonstrate its use as a verification device, providing both source position and dosimetric information.Methods: Characterization of the EPID response using an 192 Ir brachytherapy source included investigations of reproducibility, linearity with dose rate, photon energy dependence, and charge build-up effects associated with exposure time and image acquisition time. Source position resolution in three dimensions was determined. To illustrate treatment verification, a simple treatment plan was delivered to a phantom and the measured EPID dose distribution compared with the planned dose.Results: The mean absolute source position error in the plane parallel to the EPID, for dwells measured at 50, 100, and 150 mm source to detector distances (SDD), was determined to be 0.26 mm. The resolution of the z coordinate (perpendicular distance from detector plane) is SDD dependent with 95% confidence intervals of ±0.1, ±0.5, and ±2.0 mm at SDDs of 50, 100, and 150 mm, respectively. The response of the EPID is highly linear to dose rate. The EPID exhibits an over-response to low energy incident photons and this nonlinearity is incorporated into the dose calibration procedure. A distance (spectral) dependent dose rate calibration procedure has been developed. The

  12. Non-uniform dwell times in line source high dose rate brachytherapy: physical and radiobiological considerations

    International Nuclear Information System (INIS)

    Jones, B.; Tan, L.T.; Freestone, G.; Bleasdale, C.; Myint, S.; Littler, J.

    1994-01-01

    The ability to vary source dwell times in high dose rate (HDR) brachytherapy allows for the use of non-uniform dwell times along a line source. This may have advantages in the radical treatment of tumours depending on individual tumour geometry. This study investigates the potential improvements in local tumour control relative to adjacent normal tissue isoeffects when intratumour source dwell times are increased along the central portion of a line source (technique A) in radiotherapy schedules which include a relatively small component of HDR brachytherapy. Such a technique is predicted to increase the local control for tumours of diameters ranging between 2 cm and 4 cm by up to 11% compared with a technique in which there are uniform dwell times along the line source (technique B). There is no difference in the local control rates for the two techniques when used to treat smaller tumours. Normal tissue doses are also modified by the technique used. Technique A produces higher normal tissue doses at points perpendicular to the centre of the line source and lower dose at points nearer the ends of the line source if the prescription point is not in the central plane of the line source. Alternatively, if the dose is prescribed at a point in the central plane of the line source, the dose at all the normal tissue points are lower when technique A is used. (author)

  13. Development of an open source software module for enhanced visualization during MR-guided interstitial gynecologic brachytherapy.

    Science.gov (United States)

    Chen, Xiaojun; Egger, Jan

    2014-01-01

    In 2010, gynecologic malignancies were the 4th leading cause of death in U.S. women and for patients with extensive primary or recurrent disease, treatment with interstitial brachytherapy may be an option. However, brachytherapy requires precise insertion of hollow catheters with introducers into the tumor in order to eradicate the cancer. In this study, a software solution to assist interstitial gynecologic brachytherapy has been investigated and the software has been realized as an own module under (3D) Slicer, which is a free open source software platform for (translational) biomedical research. The developed research module allows on-time processing of intra-operative magnetic resonance imaging (iMRI) data over a direct DICOM connection to a MR scanner. Afterwards follows a multi-stage registration of CAD models of the medical brachytherapy devices (template, obturator) to the patient's MR images, enabling the virtual placement of interstitial needles to assist the physician during the intervention.

  14. Study and methodologies for fixing epoxy resin in radioactive sources used for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Bruna T.; Rostelato, Maria E.C.M.; Souza, Carla D.; Tozetti, Cíntia A.; Zeituni, Carlos A.; Nogueira, Beatriz R.; Silva, José T.; Júnior, Dib K.; Fernandes, Vagner; Souza, Raquel V.; Abreu, Rodrigo T., E-mail: bteigarodrigues@gmail.com, E-mail: elisaros@ipen.br, E-mail: carladdsouza@yahoo.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Universidade de São Paulo (USP), SP (Brazil)

    2017-07-01

    The World Health Organization (WHO) estimates that the number of new cancer cases worldwide will reach 15 million by 2020. The disease is already the second leading cause of death worldwide, being behind only cardiovascular disease. It is unquestionable that it is a public health problem, especially among developing countries. Prostate cancer is the most common among men, approximately 28.6%. The choice of type of treatment for prostate cancer should consider several factors such as: tumor size and extent, apparent aggressiveness (pathological characteristics), age, health. Among the methods applied, brachytherapy has been used in the initial and intermediate stages of the disease. Brachytherapy is a safe and effective treatment for localized prostate cancer. Brachytherapy is a form of radiotherapy in which radioactive seeds are placed in contact with or within the organ being treated. This technique allows a large dose of radiation to be released only on the target tumor that protects healthy surrounding tissues. Sources may have different shapes and sizes, but the one used for prostate cancer is usually 4.5 mm in length and 0.8 mm in diameter. About 80 to 120 seeds can be used per patient. Iodine-125 is the radioisotope most used in brachytherapy of the prostate, it emits 35,49keV X-rays in 100% of the decays, with average energy of 29 keV. The treatment of prostate cancer with permanent implantation of iodine-125 seeds has grown dramatically in the world in recent years. Most patients can return to normal life within three days with little or no pain. (author)

  15. Study and methodologies for fixing epoxy resin in radioactive sources used for brachytherapy

    International Nuclear Information System (INIS)

    Rodrigues, Bruna T.; Rostelato, Maria E.C.M.; Souza, Carla D.; Tozetti, Cíntia A.; Zeituni, Carlos A.; Nogueira, Beatriz R.; Silva, José T.; Júnior, Dib K.; Fernandes, Vagner; Souza, Raquel V.; Abreu, Rodrigo T.

    2017-01-01

    The World Health Organization (WHO) estimates that the number of new cancer cases worldwide will reach 15 million by 2020. The disease is already the second leading cause of death worldwide, being behind only cardiovascular disease. It is unquestionable that it is a public health problem, especially among developing countries. Prostate cancer is the most common among men, approximately 28.6%. The choice of type of treatment for prostate cancer should consider several factors such as: tumor size and extent, apparent aggressiveness (pathological characteristics), age, health. Among the methods applied, brachytherapy has been used in the initial and intermediate stages of the disease. Brachytherapy is a safe and effective treatment for localized prostate cancer. Brachytherapy is a form of radiotherapy in which radioactive seeds are placed in contact with or within the organ being treated. This technique allows a large dose of radiation to be released only on the target tumor that protects healthy surrounding tissues. Sources may have different shapes and sizes, but the one used for prostate cancer is usually 4.5 mm in length and 0.8 mm in diameter. About 80 to 120 seeds can be used per patient. Iodine-125 is the radioisotope most used in brachytherapy of the prostate, it emits 35,49keV X-rays in 100% of the decays, with average energy of 29 keV. The treatment of prostate cancer with permanent implantation of iodine-125 seeds has grown dramatically in the world in recent years. Most patients can return to normal life within three days with little or no pain. (author)

  16. Divergence of Cs-137 sources fluence used in brachytherapy

    International Nuclear Information System (INIS)

    Vianello, E.A.; Almeida, C.E. de

    1998-01-01

    In this work the experimental determination of correction factor for fluence divergence (kln) of linear Cs-137 sources CDCS J4, with Farmer ionization chamber model 2571 in a central and perpendicular plan to source axis, for distances range from 1 to 7 cm., has been presented. The experimental results were compared to calculating by Kondo and Randolph (1960) isotropic theory and Bielajew (1990) anisotropic theory. (Author)

  17. Independent assessment of source position for gynecological applicator in high-dose-rate brachytherapy.

    Science.gov (United States)

    Okamoto, Hiroyuki; Nakamura, Satoshi; Nishioka, Shie; Iijima, Kotaro; Wakita, Akihisa; Abe, Yukinao; Tohyama, Naoki; Kawamura, Shinji; Minemura, Toshiyuki; Itami, Jun

    2017-10-01

    The aim of this study is to describe a phantom designed for independent examination of a source position in brachytherapy that is suitable for inclusion in an external auditing program. We developed a phantom that has a special design and a simple mechanism, capable of firmly fixing a radiochromic film and tandem-ovoid applicators to assess discrepancies in source positions between the measurements and treatment planning system (TPS). Three tests were conducted: 1) reproducibility of the source positions ( n = 5); 2) source movements inside the applicator tube; 3) changing source position by changing curvature of the transfer tubes. In addition, as a trial study, the phantom was mailed to 12 institutions, and 23 trial data sets were examined. The source displacement ΔX and ΔY (reference = TPS) were expressed according to the coordinates, in which the positive direction on the X-axis corresponds to the external side of the applicator perpendicular to source transfer direction Y-axis. Test 1: The 1σ fell within 1 mm irrespective of the dwell positions. Test 2: ΔX were greater around the tip of the applicator owing to the source cable. Test 3: All of the source position changes fell within 1 mm. For postal audit, the mean and 1.96σ in ΔX were 0.8 and 0.8 mm, respectively. Almost all data were located within a positive region along the X-axis due to the source cable. The mean and 1.96σ in ΔY were 0.3 and 1.6 mm, respectively. The variance in ΔY was greater than that in ΔX, and large uncertainties exist in the determination of the first dwell position. The 95% confidence limit was 2.1 mm. In HDR brachytherapy, an effectiveness of independent source position assessment could be demonstrated. The 95% confidence limit was 2.1 mm for a tandem-ovoids applicator.

  18. Assessment of the risks associated with Iodine-125 handling production sources for brachytherapy

    International Nuclear Information System (INIS)

    Souza, Daiane C.B.; Rostelato, Maria Elisa C.; Vicente, Roberto; Zeituni, Carlos A.; Tiezzi, Rodrigo; Costa, Osvaldo L.; Souza, Carla D.; Peleias Junior, Fernando S.; Rodrigues, Bruna T.; Souza, Anderson S.; Batista, Talita Q.; Melo, Emerson R.; Camargo, Anderson R.; Karam Junior, Dib

    2015-01-01

    In Brazil, prostate cancer is the second most frequent disease, with an estimated 68,800 new cases in 2013. This type of cancer can be treated with brachytherapy, which uses sealed sources of Iodine-125 implanted permanently in the prostate. These sources are currently imported at a high cost, making public treatment in large scale impractical. To reduce costs and to meet domestic demand, the laboratory for production of brachytherapy sources at the Nuclear and Energy Research Institute (IPEN) is currently nationalizing the production of this radioisotope. Iodine is quite volatile making the handling of its radioactive isotopes potentially dangerous. The aim of this paper is to evaluate the risks to which workers are exposed during the production and handling of the sources. The research method consisted initially of a literature review on the toxicity of iodine, intake limits, related physical risks, handling of accidents, generation of radioactive wastes, etc. The results allowed for establishing safety and radioprotection policies in order to ensure efficient and safe production in all stages and the implementation of good laboratory practices. (author)

  19. A simplified analytical dose calculation algorithm accounting for tissue heterogeneity for low-energy brachytherapy sources

    Science.gov (United States)

    Mashouf, Shahram; Lechtman, Eli; Beaulieu, Luc; Verhaegen, Frank; Keller, Brian M.; Ravi, Ananth; Pignol, Jean-Philippe

    2013-09-01

    The American Association of Physicists in Medicine Task Group No. 43 (AAPM TG-43) formalism is the standard for seeds brachytherapy dose calculation. But for breast seed implants, Monte Carlo simulations reveal large errors due to tissue heterogeneity. Since TG-43 includes several factors to account for source geometry, anisotropy and strength, we propose an additional correction factor, called the inhomogeneity correction factor (ICF), accounting for tissue heterogeneity for Pd-103 brachytherapy. This correction factor is calculated as a function of the media linear attenuation coefficient and mass energy absorption coefficient, and it is independent of the source internal structure. Ultimately the dose in heterogeneous media can be calculated as a product of dose in water as calculated by TG-43 protocol times the ICF. To validate the ICF methodology, dose absorbed in spherical phantoms with large tissue heterogeneities was compared using the TG-43 formalism corrected for heterogeneity versus Monte Carlo simulations. The agreement between Monte Carlo simulations and the ICF method remained within 5% in soft tissues up to several centimeters from a Pd-103 source. Compared to Monte Carlo, the ICF methods can easily be integrated into a clinical treatment planning system and it does not require the detailed internal structure of the source or the photon phase-space.

  20. Determination of factors through Monte Carlo method for Fricke dosimetry from 192Ir sources for brachytherapy

    International Nuclear Information System (INIS)

    David, Mariano Gazineu; Salata, Camila; Almeida, Carlos Eduardo

    2014-01-01

    The Laboratorio de Ciencias Radiologicas develops a methodology for the determination of the absorbed dose to water by Fricke chemical dosimetry method for brachytherapy sources of 192 Ir high dose rate and have compared their results with the laboratory of the National Research Council Canada. This paper describes the determination of the correction factors by Monte Carlo method, with the Penelope code. Values for all factors are presented, with a maximum difference of 0.22% for their determination by an alternative way. (author)

  1. WE-DE-201-08: Multi-Source Rotating Shield Brachytherapy Apparatus for Prostate Cancer

    International Nuclear Information System (INIS)

    Dadkhah, H; Wu, X; Kim, Y; Flynn, R

    2016-01-01

    Purpose: To introduce a novel multi-source rotating shield brachytherapy (RSBT) apparatus for the precise simultaneous angular and linear positioning of all partially-shielded 153Gd radiation sources in interstitial needles for treating prostate cancer. The mechanism is designed to lower the detrimental dose to healthy tissues, the urethra in particular, relative to conventional high-dose-rate brachytherapy (HDR-BT) techniques. Methods: Following needle implantation, the delivery system is docked to the patient template. Each needle is coupled to a multi-source afterloader catheter by a connector passing through a shaft. The shafts are rotated by translating a moving template between two stationary templates. Shaft walls as well as moving template holes are threaded such that the resistive friction produced between the two parts exerts enough force on the shafts to bring about the rotation. Rotation of the shaft is then transmitted to the shielded source via several keys. Thus, shaft angular position is fully correlated with the position of the moving template. The catheter angles are simultaneously incremented throughout treatment as needed, and only a single 360° rotation of all catheters is needed for a full treatment. For each rotation angle, source depth in each needle is controlled by a multi-source afterloader, which is proposed as an array of belt-driven linear actuators, each of which drives a source wire. Results: Optimized treatment plans based on Monte Carlo dose calculations demonstrated RSBT with the proposed apparatus reduced urethral D 1cc below that of conventional HDR-BT by 35% for urethral dose gradient volume within 3 mm of the urethra surface. Treatment time to deliver 20 Gy with multi-source RSBT apparatus using nineteen 62.4 GBq 153 Gd sources is 117 min. Conclusions: The proposed RSBT delivery apparatus in conjunction with multiple nitinol catheter-mounted platinum-shielded 153 Gd sources enables a mechanically feasible urethra

  2. MR-based source localization for MR-guided HDR brachytherapy.

    Science.gov (United States)

    Beld, E; Moerland, M A; Zijlstra, F; Viergever, M A; Lagendijk, J J W; Seevinck, P R

    2018-04-05

    For the purpose of MR-guided high-dose-rate (HDR) brachytherapy, a method for real-time localization of an HDR brachytherapy source was developed, which requires high spatial and temporal resolutions. MR-based localization of an HDR source serves two main aims. First, it enables real-time treatment verification by determination of the HDR source positions during treatment. Second, when using a dummy source, MR-based source localization provides an automatic detection of the source dwell positions after catheter insertion, allowing elimination of the catheter reconstruction procedure. Localization of the HDR source was conducted by simulation of the MR artifacts, followed by a phase correlation localization algorithm applied to the MR images and the simulated images, to determine the position of the HDR source in the MR images. To increase the temporal resolution of the MR acquisition, the spatial resolution was decreased, and a subpixel localization operation was introduced. Furthermore, parallel imaging (sensitivity encoding) was applied to further decrease the MR scan time. The localization method was validated by a comparison with CT, and the accuracy and precision were investigated. The results demonstrated that the described method could be used to determine the HDR source position with a high accuracy (0.4-0.6 mm) and a high precision (⩽0.1 mm), at high temporal resolutions (0.15-1.2 s per slice). This would enable real-time treatment verification as well as an automatic detection of the source dwell positions.

  3. MR-based source localization for MR-guided HDR brachytherapy

    Science.gov (United States)

    Beld, E.; Moerland, M. A.; Zijlstra, F.; Viergever, M. A.; Lagendijk, J. J. W.; Seevinck, P. R.

    2018-04-01

    For the purpose of MR-guided high-dose-rate (HDR) brachytherapy, a method for real-time localization of an HDR brachytherapy source was developed, which requires high spatial and temporal resolutions. MR-based localization of an HDR source serves two main aims. First, it enables real-time treatment verification by determination of the HDR source positions during treatment. Second, when using a dummy source, MR-based source localization provides an automatic detection of the source dwell positions after catheter insertion, allowing elimination of the catheter reconstruction procedure. Localization of the HDR source was conducted by simulation of the MR artifacts, followed by a phase correlation localization algorithm applied to the MR images and the simulated images, to determine the position of the HDR source in the MR images. To increase the temporal resolution of the MR acquisition, the spatial resolution was decreased, and a subpixel localization operation was introduced. Furthermore, parallel imaging (sensitivity encoding) was applied to further decrease the MR scan time. The localization method was validated by a comparison with CT, and the accuracy and precision were investigated. The results demonstrated that the described method could be used to determine the HDR source position with a high accuracy (0.4–0.6 mm) and a high precision (⩽0.1 mm), at high temporal resolutions (0.15–1.2 s per slice). This would enable real-time treatment verification as well as an automatic detection of the source dwell positions.

  4. Calculated neutron air kerma strength conversion factors for a generically encapsulated Cf-252 brachytherapy source

    CERN Document Server

    Rivard, M J; D'Errico, F; Tsai, J S; Ulin, K; Engler, M J

    2002-01-01

    The sup 2 sup 5 sup 2 Cf neutron air kerma strength conversion factor (S sub K sub N /m sub C sub f) is a parameter needed to convert the radionuclide mass (mu g) provided by Oak Ridge National Laboratory into neutron air kerma strength required by modern clinical brachytherapy dosimetry formalisms indicated by Task Group No. 43 of the American Association of Physicists in Medicine (AAPM). The impact of currently used or proposed encapsulating materials for sup 2 sup 5 sup 2 Cf brachytherapy sources (Pt/Ir-10%, 316L stainless steel, nitinol, and Zircaloy-2) on S sub K sub N /m sub C sub f was calculated and results were fit to linear equations. Only for substantial encapsulation thicknesses, did S sub K sub N /m sub C sub f decrease, while the impact of source encapsulation composition is increasingly negligible as Z increases. These findings are explained on the basis of the non-relativistic kinematics governing the majority of sup 2 sup 5 sup 2 Cf neutron interactions. Neutron kerma and energy spectra resul...

  5. Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons.

    Science.gov (United States)

    Ballester, Facundo; Granero, Domingo; Pérez-Calatayud, José; Melhus, Christopher S; Rivard, Mark J

    2009-09-01

    The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides (60Co, 137CS, 192Ir, and 169Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source beta-, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the 192Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Electronic equilibrium within 1% is reached for 60Co, 137CS, 192Ir, and 169Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for 60Co and 192Ir, respectively. Electron emissions become important (i.e., > 0.5%) within 3.3 mm of 60Co and 1.7 mm of 192Ir sources, yet are negligible over all distances for 137Cs and 169Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

  6. Comparison between methods for fixing radioactive iodine in silver substrate for manufacturing brachytherapy sources

    International Nuclear Information System (INIS)

    Souza, Carla Daruich

    2012-01-01

    Among the different ways to treat prostate cancer, brachytherapy with iodine- 125 seeds is an option that provides good results and fewer side effects. In the present study several deposition methods of radioactive iodine in a silver substrate were compared in order to choose the most suitable alternative for the routine production to be implemented at IPEN's laboratory. The methodology used was chosen based on the available infrastructure and experience of the researchers present. Therefore, the 131 I was used for testing (same chemical behavior as 131 I). Four methods were selected: Method 1 (test based on electrodeposition method developed by D.Kubiatowicz) presented 65.16% efficiency; Method 2 (chemical reaction based on the method developed by D. Kubiatowicz - HCl) with the result of 70.80% efficiency; method 3 (chemical reaction based on the method developed by Dr. Maria Elisa Rostelato) with 55.80% efficiency; Method 4 (IQ-IPEN) resulted in 99% efficiency. Since this method has more radioactive material fixation (which represents virtually the entire cost of the seed), the final price is the cheapest. This method is the suggested one to be implemented in the IPEN's laboratory for brachytherapy sources production. Besides, the method is the fasted one. (author)

  7. Experimental derivation of the fluence non-uniformity correction for air kerma near brachytherapy linear sources

    International Nuclear Information System (INIS)

    Vianello, E. A.; Almeida, C. E. de

    2008-01-01

    In brachytherapy, one of the elements to take into account for measurements free in air is the non-uniformity of the photon fluence due to the beam divergence that causes a steep dose gradient near the source. The correction factors for this phenomenon have been usually evaluated by two available theories by Kondo and Randolph [Radiat. Res. 13, 37-60 (1960)] and Bielajew [Phys. Med. Biol. 35, 517-538 (1990)], both conceived for point sources. This work presents the experimental validation of the Monte Carlo calculations made by Rodriguez and deAlmeida [Phys. Med. Biol. 49, 1705-1709 (2004)] for the non-uniformity correction specifically for a Cs-137 linear source measured using a Farmer type ionization chamber. The experimental values agree very well with the Monte Carlo calculations and differ from the results predicted by both theoretical models widely used. This result confirms that for linear sources there are some important differences at short distances from the source and emphasizes that those theories should not be used for linear sources. The data provided in this study confirm the limitations of the mentioned theories when linear sources are used. Considering the difficulties and uncertainties associated with the experimental measurements, it is recommended to use the Monte Carlo data to assess the non-uniformity factors for linear sources in situations that require this knowledge

  8. Investigations into the Optimization of Multi-Source Strength Brachytherapy Treatment Procedures

    CERN Document Server

    Henderson, D L; Yoo, S

    2002-01-01

    The goal of this project is to investigate the use of multi-strength and multi-specie radioactive sources in permanent prostate implant brachytherapy. In order to fulfill the requirement for an optimal dose distribution, the prescribed dose should be delivered to the target in a nearly uniform dose distribution while simultaneously sparing sensitive structures. The treatment plan should use a small number of needles and sources while satisfying the treatment requirements. The hypothesis for the use of multi-strength and/or multi-specie sources is that a better treatment plan using fewer sources and needles could be obtained than by treatment plans using single-strength sources could reduce the overall number of sources used for treatment. We employ a recently developed greedy algorithm based on the adjoint concept as the optimization search engine. The algorithm utilizes and ''adjoint ratio'', which provides a means of ranking source positions, as the pseudo-objective function. It ha s been shown that the gre...

  9. Calibration of photon and beta ray sources used in brachytherapy. Guidelines on standardized procedures at Secondary Standards Dosimetry Laboratories

    International Nuclear Information System (INIS)

    2004-03-01

    It has generally been recognized that international harmonization in radiotherapy dosimetry is essential. Consequently, the IAEA has given much effort to this, for example by publishing a number of reports in the Technical Reports Series (TRS) for external beam dosimetry, most notably TRS-277 and more recently TRS-398. Both of these reports describe in detail the steps to be taken for absorbed dose determination in water and they are often referred to as 'dosimetry protocols'. Similar to TRS-277, it is expected that TRS-398 will be adopted or used as a model by a large number of countries as their national protocol. In 1996, the IAEA established a calibration service for low dose rate (LDR) 137 Cs brachytherapy sources, which is the most widely used source for treatment of gynecological cancer. To further enhance harmonization in brachytherapy dosimetry, the IAEA published in 1999 IAEA-TECDOC-1079 entitled 'Calibration of Brachytherapy Sources. Guidelines on Standardized Procedures for the Calibration of Brachytherapy Sources at Secondary Standard Dosimetry Laboratories (SSDLs) and Hospitals'. The report was well received and was distributed in a large number of copies to the members of the IAEA/WHO network of SSDLs and to medical physicists working with brachytherapy. The present report is an update of the aforementioned TECDOC. Whereas TECDOC-1079 described methods for calibrating brachytherapy sources with photon energies at or above those of 192 Ir, the current report has a wider scope in that it deals with standardization of calibration of all the most commonly used brachytherapy sources, including both photon and beta emitting sources. The latter sources have been in use for a few decades already, but their calibration methods have been unclear. Methods are also described for calibrating sources used in the rapidly growing field of cardiovascular angioplasty. In this application, irradiation of the vessel wall is done in an attempt to prevent restenosis after

  10. RADIOLOGICAL CRITERIA FOR PATIENT RELEASE FROM CLINIC AFTER RADIONUCLIDE THERAPY OF BRACHYTHERAPY WITH SEALED SOURCE IMPLANTATION

    Directory of Open Access Journals (Sweden)

    M. I. M.I. Balonov

    2009-01-01

    Full Text Available Dose criteria for limitation of exposure incurred by persons helping the patients or living with patients discharged from hospitals following radionuclide therapy or brachytherapy with implanted sealed radionuclide sources have been proposed for national Russian regulation. By means of a conservative dosimetry model, the values of operational radiological criteria for patient discharge from hospital are substantiated, i.e. whole body activity for radionuclides 125I,131I,153Sm and 188Re as well as dose rate near patient body. Observance of suggested criteria included in the new Russian Standards for Radiation Safety (RSS-99/2009 will ensure radiation safety of people in near environment (family, close friends et ah.

  11. Performance assessment of the BEBIG MultiSource® high dose rate brachytherapy treatment unit

    Science.gov (United States)

    Palmer, Antony; Mzenda, Bongile

    2009-12-01

    A comprehensive system characterisation was performed of the Eckert & Ziegler BEBIG GmbH MultiSource® High Dose Rate (HDR) brachytherapy treatment unit with an 192Ir source. The unit is relatively new to the UK market, with the first installation in the country having been made in the summer of 2009. A detailed commissioning programme was devised and is reported including checks of the fundamental parameters of source positioning, dwell timing, transit doses and absolute dosimetry of the source. Well chamber measurements, autoradiography and video camera analysis techniques were all employed. The absolute dosimetry was verified by the National Physical Laboratory, UK, and compared to a measurement based on a calibration from PTB, Germany, and the supplied source certificate, as well as an independent assessment by a visiting UK centre. The use of the 'Krieger' dosimetry phantom has also been evaluated. Users of the BEBIG HDR system should take care to avoid any significant bend in the transfer tube, as this will lead to positioning errors of the source, of up to 1.0 mm for slight bends, 2.0 mm for moderate bends and 5.0 mm for extreme curvature (depending on applicators and transfer tube used) for the situations reported in this study. The reason for these errors and the potential clinical impact are discussed. Users should also note the methodology employed by the system for correction of transit doses, and that no correction is made for the initial and final transit doses. The results of this investigation found that the uncorrected transit doses lead to small errors in the delivered dose at the first dwell position, of up to 2.5 cGy at 2 cm (5.6 cGy at 1 cm) from a 10 Ci source, but the transit dose correction for other dwells was accurate within 0.2 cGy. The unit has been mechanically reliable, and source positioning accuracy and dwell timing have been reproducible, with overall performance similar to other existing HDR equipment. The unit is capable of high

  12. Comparison between methods for fixing radioactive iodine in silver substrate for manufacturing brachytherapy sources

    International Nuclear Information System (INIS)

    Peleias Junior, Fernando S.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.

    2013-01-01

    Cancer is a term used generically to represent a group of more than 100 illnesses, including malignant tumors from different locations. According to World Health Organization (WHO), is a leading cause of death worldwide, accounted for 7.6 million deaths. Prostate cancer is the sixth most common type in the world, representing about 10% of all cases of cancer and its treatment may be by surgery, radiotherapy or even vigilant observation. A method of radiotherapy which has been extensively used in the early and intermediate stages of the illness is brachytherapy, where radioactive seeds are placed inside or next to the area requiring treatment, which reduces the probability of unnecessary damage to surrounding healthy tissues. Currently, the radioactive isotope Iodine-125, adsorbed on silver substrate, is one of the most used in prostate brachytherapy. The present study compares several deposition methods of radioactive Iodine on silver substrate, in order to choose the most suitable one to be implemented at the laboratory of radioactive sources production of IPEN. The methodology used was chosen based on the available infrastructure and experience of the researchers of the institute. Therefore, Iodine-131 was used for testing (same chemical behavior of Iodine -125). Three methods were selected: method 1 (test based on electrodeposition method, developed by David Kubiatowicz) which presented efficiency of 65.16% ; method 2 (chemical reaction based on the method developed by David Kubiatowicz -HCl) which presented efficiency of 70.80%; method 3 (chemical reaction based on the method developed by Dr. Maria Elisa Rostelato) which presented efficiency of 55.80% . Based on the results, the second method is the suggested one to be implemented at the laboratory of radioactive sources production of IPEN. (author)

  13. Monte Carlo modeling of 60 Co HDR brachytherapy source in water and in different solid water phantom materials

    Directory of Open Access Journals (Sweden)

    Sahoo S

    2010-01-01

    Full Text Available The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source-detector distance. A solid phantom can be precisely machined and hence source-detector distances can be accurately determined. In the present study, four different solid phantom materials such as polymethylmethacrylate (PMMA, polystyrene, Solid Water, and RW1 are modeled using the Monte Carlo methods to investigate the influence of phantom material on dose rate distributions of the new model of BEBIG 60 Co brachytherapy source. The calculated dose rate constant is 1.086 ± 0.06% cGy h−1 U−1 for water, PMMA, polystyrene, Solid Water, and RW1. The investigation suggests that the phantom materials RW1 and Solid Water represent water-equivalent up to 20 cm from the source. PMMA and polystyrene are water-equivalent up to 10 cm and 15 cm from the source, respectively, as the differences in the dose data obtained in these phantom materials are not significantly different from the corresponding data obtained in liquid water phantom. At a radial distance of 20 cm from the source, polystyrene overestimates the dose by 3% and PMMA underestimates it by about 8% when compared to the corresponding data obtained in water phantom.

  14. A Comparison of the Dosimetric Parameters of Cs-137 Brachytherapy Source in Different Tissues with Water Using Monte Carlo Simulation

    Directory of Open Access Journals (Sweden)

    Sedigheh Sina

    2012-03-01

    Full Text Available Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM, this method has been known as the most common dose calculation method in brachytherapy treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the water phantom is different from that of different tissues. The purpose of this study is to investigate the effects of the phantom materials on the TG-43 dosimetery parameters of the Cs-137 brachytherapy source using MCNP4C Monte Carlo code. Materials and Methods In this research, the Cs-137 (Model Selectron brachytherapy source was simulated in different phantoms (bone, soft tissue, muscle, fat, and the inhomogeneous phantoms of water/bone of volume 27000 cm3 using MCNP4C Monte Carlo code. *F8 tally was used to obtain the dose in a fine cubical lattice. Then the TG-43 dosimetry parameters of the brachytherapy source were obtained in water phantom and compared with those of different phantoms. Results The percentage difference between the radial dose function g(r of bone and the g(r of water phantom, at a distance of 10 cm from the source center is 20%, while such differences are 1.7%, 1.6% and 1.1% for soft tissue, muscle, and fat, respectively. The largest difference of the dose rate constant of phantoms with those of water is 4.52% for the bone phantom, while the differences for soft tissue, muscle, and fat are 1.18%, 1.27%, and 0.18%, respectively. The 2D anisotropy function of the Cs-137 source for different tissues is identical to that of water. Conclusion The results of the simulations have shown that dose calculation in water phantom would introduce errors in the dose calculation around brachytherapy sources. Therefore, it is suggested that the correction factors of different tissues be applied after dose calculation in water phantoms, in order to

  15. Methodology study for fixation of radioactive iodine in polymeric substrate for brachytherapy sources

    International Nuclear Information System (INIS)

    Rodrigues, Bruna T.; Rostelato, Maria Elisa C.M.; Souza, Carla D.; Tiezzi, Rodrigo; Souza, Daiane B. de; Benega, Marcos A.G.; Souza, Anderson S. de; Peleias Junior, Fernando S.; Zeituni, Calos A.; Fernandes, Vagner; Melo, Emerson Ronaldo de; Camargo, Anderson Rogerio de

    2015-01-01

    Cancer is now the second leading cause of death by disease in several countries, including Brazil. Prostate cancer is the most common among men. Brachytherapy is a modality of radiotherapy in which radioactive seeds are placed inside or in contact with the organ to be treated. The most widely used radioisotope in prostate brachytherapy is Iodine-125 which is presented fixated on a silver substrate that is subsequently placed inside a titanium capsule. A large dose of radiation is released only in the targeted tumor protecting healthy surrounding tissues. The technique requires the application of 80 - 120 seeds per patient. The implants of seeds have low impact and non-surgical procedures. Most patients can return to normal life within three days with little or no pain. This work proposes an alternative to the seeds that have already been developed, in order to reduce the cost by obtaining a better efficiency on fixing the radioactive iodine onto the epoxy resin. Methods have been developed to perform the fixation of Iodine-125 onto polymeric substrates. The parameters analyzed were the immersion time, type of static or dynamic reaction, concentration of the adsorption solution, the specific activity of the radioactive source, the need for carrier and chemical form of the radioactive Iodine. These experiments defined the most effective method to fixate the Iodine onto the polymeric material (epoxy resin), the Iodine activity in the polymeric substrate, the activity of the distribution of variation in a plot of polymeric cores and the efficiency of the epoxy resin to seal the seed. (author)

  16. Methodology study for fixation of radioactive iodine in polymeric substrate for brachytherapy sources

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Bruna T.; Rostelato, Maria Elisa C.M.; Souza, Carla D.; Tiezzi, Rodrigo; Souza, Daiane B. de; Benega, Marcos A.G.; Souza, Anderson S. de; Peleias Junior, Fernando S.; Zeituni, Calos A.; Fernandes, Vagner; Melo, Emerson Ronaldo de; Camargo, Anderson Rogerio de, E-mail: bteigarodrigues@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Cancer is now the second leading cause of death by disease in several countries, including Brazil. Prostate cancer is the most common among men. Brachytherapy is a modality of radiotherapy in which radioactive seeds are placed inside or in contact with the organ to be treated. The most widely used radioisotope in prostate brachytherapy is Iodine-125 which is presented fixated on a silver substrate that is subsequently placed inside a titanium capsule. A large dose of radiation is released only in the targeted tumor protecting healthy surrounding tissues. The technique requires the application of 80 - 120 seeds per patient. The implants of seeds have low impact and non-surgical procedures. Most patients can return to normal life within three days with little or no pain. This work proposes an alternative to the seeds that have already been developed, in order to reduce the cost by obtaining a better efficiency on fixing the radioactive iodine onto the epoxy resin. Methods have been developed to perform the fixation of Iodine-125 onto polymeric substrates. The parameters analyzed were the immersion time, type of static or dynamic reaction, concentration of the adsorption solution, the specific activity of the radioactive source, the need for carrier and chemical form of the radioactive Iodine. These experiments defined the most effective method to fixate the Iodine onto the polymeric material (epoxy resin), the Iodine activity in the polymeric substrate, the activity of the distribution of variation in a plot of polymeric cores and the efficiency of the epoxy resin to seal the seed. (author)

  17. Influence of radioactive sources discretization in the Monte Carlo computational simulations of brachytherapy procedures: a case study on the procedures for treatment of prostate cancer

    International Nuclear Information System (INIS)

    Barbosa, Antonio Konrado de Santana; Vieira, Jose Wilson; Costa, Kleber Souza Silva; Lima, Fernando Roberto de Andrade

    2011-01-01

    Radiotherapy computational simulation procedures using Monte Carlo (MC) methods have shown to be increasingly important to the improvement of cancer fighting strategies. One of the biases in this practice is the discretization of the radioactive source in brachytherapy simulations, which often do not match with a real situation. This study had the aim to identify and to measure the influence of radioactive sources discretization in brachytherapy MC simulations when compared to those that do not present discretization, using prostate brachytherapy with Iodine-125 radionuclide as model. Simulations were carried out with 108 events with both types of sources to compare them using EGSnrc code associated to MASH phantom in orthostatic and supine positions with some anatomic adaptations. Significant alterations were found, especially regarding bladder, rectum and the prostate itself. It can be concluded that there is a need to discretized sources in brachytherapy simulations to ensure its representativeness. (author)

  18. Preparation and determination of kerma for Iridium 192 sources of low dose rate for brachytherapy

    International Nuclear Information System (INIS)

    Tendilla, J.I.; Tovar M, V.; Mitsoura, E.; Aguilar H, F.; Alanis M, J.

    2000-01-01

    The practice of Brachytherapy with Iridium-192 sources of low dose rate (0.4 - 0.8 Gy/h) is a technique used in the treatment of diverse illnesses. in this work the preparation, quality control and calibration are presented in terms of kerma in air of Iridium-192 using as target these recycled Iridium-Platinum wires. The targets were obtained as decayed sources of different radio therapeutical centers in the country and they were characterized by Scanning electron microscopy in order to determine their chemical composition. Subsequently it was developed an experimental design to establish the effect of neutron flux, geometrical array and irradiation time over the activity and percentage of the sources homogeneity. The homogeneity was determined by auto radiography and by Gamma spectroscopy. Once the optimal irradiation conditions were established, it is determined the apparent activity and kerma in air using a well type ionization chamber with traceability to a primary laboratory. Iridium-192 sources were obtained with an average homogeneity 96 %, apparent activity 282.129 ± 0.531 M Bq and kerma in air 0.03200 ± 0.00006 m Gy m/h A. (Author)

  19. Dosimetric study of a brachytherapy treatment of esophagus with Brazilian 192Ir sources using an anthropomorphic phantom

    Science.gov (United States)

    Neves, Lucio P.; Santos, William S.; Gorski, Ronan; Perini, Ana P.; Maia, Ana F.; Caldas, Linda V. E.; Orengo, Gilberto

    2014-11-01

    Several radioisotopes are produced at Instituto de Pesquisas Energéticas e Nucleares for the use in medical treatments, including the activation of 192Ir sources. These sources are suitable for brachytherapy treatments, due to their low or high activity, depending on the concentration of 192Ir, easiness to manufacture, small size, stable daughter products and the possibility of re-utilization. They may be used for the treatment of prostate, cervix, head and neck, skin, breast, gallbladder, uterus, vagina, lung, rectum, and eye cancer treatment. In this work, the use of some 192Ir sources was studied for the treatment of esophagus cancer, especially the dose determination of important structures, such as those on the mediastinum. This was carried out utilizing a FASH anthropomorphic phantom and the MCNP5 Monte Carlo code to transport the radiation through matter. It was possible to observe that the doses at lungs, breast, esophagus, thyroid and heart were the highest, which was expected due to their proximity to the source. Therefore, the data are useful to assess the representative dose specific to brachytherapy treatments on the esophagus for radiation protection purposes. The use of brachytherapy sources was studied for the treatment of esophagus cancer. FASH anthropomorphic phantom and MCNP5 Monte Carlo code were employed. The doses at lungs, breast, esophagus, thyroid and heart were the highest. The data is useful to assess the representative doses of treatments on the esophagus.

  20. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V.

    1998-01-01

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  1. Importance of the neutrons kerma coefficient in the planning of Brachytherapy treatments with Cf-252 sources

    International Nuclear Information System (INIS)

    Paredes G, L.; Balcazar G, M.; Azorin N, J.; Francois L, J.L.

    2006-01-01

    The Cf-252 is a fast neutrons emitting radioisotope by spontaneous fission that can be used as sealed source in medicine applications, industry and research. Commercially its offer sources of different sizes, compact and with a fast neutrons emission of the order of 10 6 n/s-μg and an energy spectra that presents respectively maxim and average energy in 2.1 MeV and 0.7 MeV. In medicine new applications are being developed for the treatment of patient with hypoxic and voluminous tumors, where the therapy with photons has not given positive results, as well as for the protocols of therapy treatment by boron neutron capture, where very small sources of Cf-252 will be used with the interstitial brachytherapy technique of high and low dose rate. In this work an analysis of how the small differences that exist in the elementary composition of 4 wicked tumors, 4 ICRU healthy tissues and 3 substitute materials of ICRU tissue used in dosimetry are presented, its generate changes in the neutrons kerma coefficient in function of the energy and consequently in the absorbed dose in the interval of 11 eV to 29 MeV. These differences can produce maximum variations of the neutron kerma coefficients ratio for E n > 1 keV of the one: 15% tumor/ICRU guest healthy tissue, 12% ICRU tumor/muscle, 12% ICRU healthy tissues ICRU/ICRU muscle, 22% substitutes tissue/tumor and 22% ICRU substitutes tissue/muscle. Also, it was found that the average value of the neutrons kerma coefficient for the 4 wicked tumors is from 6% to 7% smaller that the average value for the soft tissue in the interval energy of interest for therapy with fast neutrons with E n > 1 MeV. These results have a special importance during the planning process of brachytherapy treatments with sources of 252 Cf, to optimize and to individualize the patients treatments. (Author)

  2. Theoretical and experimental determination of dosimetric characteristics for ADVANTAGETM Pd-103 brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Dini, Sharifeh A.; Awan, Shahid B.; Dou, Kai; Koona, Rafiq A.

    2006-01-01

    ADVANTAGE TM Pd-103 brachytherapy source has been recently introduced by IsoAid TM for prostate permanent implants. Dosimetric characteristics (Dose rate constant, radial dose function, 2D-, and 1D-anisotropy functions) of this source model have been determined using both theoretical and experimental methods, following the updated TG-43U1 protocol. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with the 1999 Standards. Measurements were performed in Solid Water TM using LiF TLD chips and the theoretical calculations were performed in Solid Water TM and liquid water phantom materials using PTRAN Monte Carlo code. The results of the Monte Carlo simulation have shown a dose rate constant of 0.69 cGy h -1 U -1 in liquid water and 0.67 cGy h -1 U -1 in Solid Water TM medium. The measured dose rate constant in Solid Water TM was found to be 0.68±8% cGy h -1 U -1 , which is in a good agreement (within ±5%) to the Monte Carlo simulated data. The 2D- and 1D-anisotropy functions of the ADVANTAGE TM Pd-103 source were calculated for radial distances ranging from 0.5 to 5.0 cm. Radial dose function was determined for radial distances ranging from 0.2 to 8.0 cm using line source approximation. All these calculations are based on L eff equal to 3.61 cm, calculated following TG-43U1 recommendations. The tabulated data for 2D-anisotropy function, 1D-anisotropy function, dose rate constant and radial dose function have been produced for clinical application of this source model

  3. Source strength verification and quality assurance of preloaded brachytherapy needles using a CMOS flat panel detector.

    Science.gov (United States)

    Golshan, Maryam; Spadinger, Ingrid; Chng, Nick

    2016-06-01

    Current methods of low dose rate brachytherapy source strength verification for sources preloaded into needles consist of either assaying a small number of seeds from a separate sample belonging to the same lot used to load the needles or performing batch assays of a subset of the preloaded seed trains. Both of these methods are cumbersome and have the limitations inherent to sampling. The purpose of this work was to investigate an alternative approach that uses an image-based, autoradiographic system capable of the rapid and complete assay of all sources without compromising sterility. The system consists of a flat panel image detector, an autoclavable needle holder, and software to analyze the detected signals. The needle holder was designed to maintain a fixed vertical spacing between the needles and the image detector, and to collimate the emissions from each seed. It also provides a sterile barrier between the needles and the imager. The image detector has a sufficiently large image capture area to allow several needles to be analyzed simultaneously.Several tests were performed to assess the accuracy and reproducibility of source strengths obtained using this system. Three different seed models (Oncura 6711 and 9011 (125)I seeds, and IsoAid Advantage (103)Pd seeds) were used in the evaluations. Seeds were loaded into trains with at least 1 cm spacing. Using our system, it was possible to obtain linear calibration curves with coverage factor k = 1 prediction intervals of less than ±2% near the centre of their range for the three source models. The uncertainty budget calculated from a combination of type A and type B estimates of potential sources of error was somewhat larger, yielding (k = 1) combined uncertainties for individual seed readings of 6.2% for (125)I 6711 seeds, 4.7% for (125)I 9011 seeds, and 11.0% for Advantage (103)Pd seeds. This study showed that a flat panel detector dosimetry system is a viable option for source strength verification in

  4. Determination of task group 43 dosimetric parameters for CSM40 137Cs source for use in brachytherapy.

    Science.gov (United States)

    Firoozabadi, Mohammad Mehdi; Jimabadi, Elaheh; Ghorbani, Mahdi; Behmadi, Marziyeh

    2018-03-01

    The CSM40 137 Cs source model is currently being used in clinical brachytherapy. According to the recommendations of task group No. 43 (TG-43) of the American Association of Physicists in Medicine, dosimetry parameters of brachytherapy sources should be determined by two independent investigators before their clinical use. The aim of this study was to determine the TG-43 dosimetry parameters for a medium-dose-rate CSM40 137 Cs source. The determined dosimetric parameters included the air kerma strength, dose rate constant, radial dose function, and anisotropy function. To determine the source's dosimetric parameters, the CSM40 source was stimulated by the Monte Carlo N-Particle MCNP code. The TG-43 parameters were compared with the data of Vijande et al. on this source. The results showed that the dosimetry parameters for this source had good agreement with the results of Vijande et al. The dosimetric parameters of the CSM40 source can be used in treatment-planning systems incorporating this source model. The data can also be used for the quality assurance of treatment-planning systems.

  5. Investigations into the Optimization of Multi-Source Strength Brachytherapy Treatment Procedures

    International Nuclear Information System (INIS)

    Henderson, D. L.; Yoo, S.; Thomadsen, B.R.

    2002-01-01

    The goal of this project is to investigate the use of multi-strength and multi-specie radioactive sources in permanent prostate implant brachytherapy. In order to fulfill the requirement for an optimal dose distribution, the prescribed dose should be delivered to the target in a nearly uniform dose distribution while simultaneously sparing sensitive structures. The treatment plan should use a small number of needles and sources while satisfying the treatment requirements. The hypothesis for the use of multi-strength and/or multi-specie sources is that a better treatment plan using fewer sources and needles could be obtained than by treatment plans using single-strength sources could reduce the overall number of sources used for treatment. We employ a recently developed greedy algorithm based on the adjoint concept as the optimization search engine. The algorithm utilizes and ''adjoint ratio'', which provides a means of ranking source positions, as the pseudo-objective function. It ha s been shown that the greedy algorithm can solve the optimization problem efficiently and arrives at a clinically acceptable solution in less than 10 seconds. Our study was inclusive, that is there was no combination of sources that clearly stood out from the others and could therefore be considered the preferred set of sources for treatment planning. Source strengths of 0.2 mCi (low), 0.4 mCi (medium), and 0.6 mCi (high) of 125 I in four different combinations were used for the multi-strength source study. The combination of high- and medium-strength sources achieved a more uniform target dose distribution due to few source implants whereas the combination of low-and medium-strength sources achieved better sparing of sensitive tissues including that of the single-strength 0.4 mCi base case. 125 I at 0.4 mCi and 192 Ir at 0.12 mCi and 0.25 mCi source strengths were used for the multi-specie source study. This study also proved inconclusive , Treatment plans using a combination of two 0

  6. Investigations into the Optimization of Multi-Source Strength Brachytherapy Treatment Procedures

    Energy Technology Data Exchange (ETDEWEB)

    D. L. Henderson; S. Yoo; B.R. Thomadsen

    2002-09-30

    The goal of this project is to investigate the use of multi-strength and multi-specie radioactive sources in permanent prostate implant brachytherapy. In order to fulfill the requirement for an optimal dose distribution, the prescribed dose should be delivered to the target in a nearly uniform dose distribution while simultaneously sparing sensitive structures. The treatment plan should use a small number of needles and sources while satisfying the treatment requirements. The hypothesis for the use of multi-strength and/or multi-specie sources is that a better treatment plan using fewer sources and needles could be obtained than by treatment plans using single-strength sources could reduce the overall number of sources used for treatment. We employ a recently developed greedy algorithm based on the adjoint concept as the optimization search engine. The algorithm utilizes and ''adjoint ratio'', which provides a means of ranking source positions, as the pseudo-objective function. It ha s been shown that the greedy algorithm can solve the optimization problem efficiently and arrives at a clinically acceptable solution in less than 10 seconds. Our study was inclusive, that is there was no combination of sources that clearly stood out from the others and could therefore be considered the preferred set of sources for treatment planning. Source strengths of 0.2 mCi (low), 0.4 mCi (medium), and 0.6 mCi (high) of {sup 125}I in four different combinations were used for the multi-strength source study. The combination of high- and medium-strength sources achieved a more uniform target dose distribution due to few source implants whereas the combination of low-and medium-strength sources achieved better sparing of sensitive tissues including that of the single-strength 0.4 mCi base case. {sup 125}I at 0.4 mCi and {sup 192}Ir at 0.12 mCi and 0.25 mCi source strengths were used for the multi-specie source study. This study also proved inconclusive , Treatment

  7. Dosimetric characteristics of the Best registered double-wall 103Pd brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, A.S.; Bharucha, Z.; Yoe-Sein, M.; Sowards, Keith

    2001-01-01

    103 Pd and 125 I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, a double-wall 103 Pd source has been introduced, which has a design different from that of sources presently on the market. Dosimetric characteristics (dose rate constant, radial dose function, and anisotropy function) of this source were experimentally and theoretically determined following the AAPM Task Group 43 recommendations and were related to the October 10, 2000 revision of the NIST 1999 S K Standard for 103 Pd. Measurements were performed in a Solid Water trade mark sign phantom using LiF thermoluminescent dosimeters. For these measurements, slabs of Solid Water trade mark sign phantom material were machined to accommodate the source and LiF TLD chips of dimensions (3.1x3.1x0.8 mm 3 ) and (1.0x1.0x1.0 mm 3 ). The TLD chips were surrounded by at least 10 cm of Solid Water trade mark sign phantom material to provide full scattering conditions. The Monte Carlo simulations were performed in Solid Water trade mark sign and liquid water using the PTRAN code. The results of this investigation show an excellent agreement (within 5%) between the measured (0.67±8% cGy h -1 U -1 ) and calculated (to be 0.65±3% cGy h -1 U -1 ) dose rate constant in Solid Water trade mark sign . The Monte Carlo calculated dose rate constant of the Best registered 103 Pd in water was found to be 0.67±0.02 cGy h -1 U -1 . The radial dose function, g(r), of the new 103 Pd source was measured at distances ranging from 0.5 and 7 cm using LiF TLD in Solid Water trade mark sign phantom material. Moreover, the radial dose function of the new source was calculated in liquid water and Solid Water trade mark sign at distances ranging from 0.1 to 7 cm using the PTRAN Monte Carlo Code. The anisotropy function, F(r,θ), of the new 103 Pd source was also measured in Solid Water trade mark sign and calculated in both Solid Water trade mark sign and water phantom material

  8. An open-source genetic algorithm for determining optimal seed distributions for low-dose-rate prostate brachytherapy.

    Science.gov (United States)

    McGeachy, P; Madamesila, J; Beauchamp, A; Khan, R

    2015-01-01

    An open source optimizer that generates seed distributions for low-dose-rate prostate brachytherapy was designed, tested, and validated. The optimizer was a simple genetic algorithm (SGA) that, given a set of prostate and urethra contours, determines the optimal seed distribution in terms of coverage of the prostate with the prescribed dose while avoiding hotspots within the urethra. The algorithm was validated in a retrospective study on 45 previously contoured low-dose-rate prostate brachytherapy patients. Dosimetric indices were evaluated to ensure solutions adhered to clinical standards. The SGA performance was further benchmarked by comparing solutions obtained from a commercial optimizer (inverse planning simulated annealing [IPSA]) with the same cohort of 45 patients. Clinically acceptable target coverage by the prescribed dose (V100) was obtained for both SGA and IPSA, with a mean ± standard deviation of 98 ± 2% and 99.5 ± 0.5%, respectively. For the prostate D90, SGA and IPSA yielded 177 ± 8 Gy and 186 ± 7 Gy, respectively, which were both clinically acceptable. Both algorithms yielded reasonable dose to the rectum, with V100 < 0.3 cc. A reduction in dose to the urethra was seen using SGA. SGA solutions showed a slight prostate volume dependence, with smaller prostates (<25 cc) yielding less desirable, although still clinically viable, dosimetric outcomes. SGA plans used, on average, fewer needles than IPSA (21 vs. 24, respectively), which may lead to a reduction in urinary toxicity and edema that alters post-implant dosimetry. An open source SGA was validated that provides a research tool for the brachytherapy community. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  9. A phantom for verification of dwell position and time of a high dose rate brachytherapy source

    International Nuclear Information System (INIS)

    Madebo, M.; Kron, T.; Pillainayagam, J.; Franich, R.

    2012-01-01

    Accuracy of dwell position and reproducibility of dwell time are critical in high dose rate (HDR) brachytherapy. A phantom was designed to verify dwell position and dwell time reproducibility for an Ir-192 HDR stepping source using Computed Radiography (CR). The central part of the phantom, incorporating thin alternating strips of lead and acrylic, was used to measure dwell positions. The outer part of the phantom features recesses containing different absorber materials (lead, aluminium, acrylic and polystyrene foam), and was used for determining reproducibility of dwell times. Dwell position errors of <1 mm were easily detectable using the phantom. The effect of bending a transfer tube was studied with this phantom and no change of clinical significance was observed when varying the curvature of the transfer tube in typical clinical scenarios. Changes of dwell time as low as 0.1 s, the minimum dwell time of the treatment unit, could be detected by choosing dwell times over the four materials that produce identical exposure at the CR detector.

  10. The wall correction factor for a spherical ionization chamber used in brachytherapy source calibration

    Science.gov (United States)

    Piermattei, A.; Azario, L.; Fidanzio, A.; Viola, P.; Dell'Omo, C.; Iadanza, L.; Fusco, V.; Lagares, J. I.; Capote, R.

    2003-12-01

    The effect of wall chamber attenuation and scattering is one of the most important corrections that must be determined when the linear interpolation method between two calibration factors of an ionization chamber is used. For spherical ionization chambers the corresponding correction factors Aw have to be determined by a non-linear trend of the response as a function of the wall thickness. The Monte Carlo and experimental data here reported show that the Aw factors obtained for an Exradin A4 chamber, used in the brachytherapy source calibration, in terms of reference air kerma rate, are up to 1.2% greater than the values obtained by the linear extrapolation method for the studied beam qualities. Using the Aw factors derived from Monte Carlo calculations, the accuracy of the calibration factor NK,Ir for the Exradin A4, obtained by the interpolation between two calibration factors, improves about 0.6%. The discrepancy between the new calculated factor and that obtained using the complete calibration curve of the ion-chamber and the 192Ir spectrum is only 0.1%.

  11. Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE.

    Science.gov (United States)

    Almansa, Julio F; Guerrero, Rafael; Torres, Javier; Lallena, Antonio M

    60 Co sources have been commercialized as an alternative to 192 Ir sources for high-dose-rate (HDR) brachytherapy. One of them is the Flexisource Co-60 HDR source manufactured by Elekta. The only available dosimetric characterization of this source is that of Vijande et al. [J Contemp Brachytherapy 2012; 4:34-44], whose results were not included in the AAPM/ESTRO consensus document. In that work, the dosimetric quantities were calculated as averages of the results obtained with the Geant4 and PENELOPE Monte Carlo (MC) codes, though for other sources, significant differences have been quoted between the values obtained with these two codes. The aim of this work is to perform the dosimetric characterization of the Flexisource Co-60 HDR source using PENELOPE. The MC simulation code PENELOPE (v. 2014) has been used. Following the recommendations of the AAPM/ESTRO report, the radial dose function, the anisotropy function, the air-kerma strength, the dose rate constant, and the absorbed dose rate in water have been calculated. The results we have obtained exceed those of Vijande et al. In particular, the absorbed dose rate constant is ∼0.85% larger. A similar difference is also found in the other dosimetric quantities. The effect of the electrons emitted in the decay of 60 Co, usually neglected in this kind of simulations, is significant up to the distances of 0.25 cm from the source. The systematic and significant differences we have found between PENELOPE results and the average values found by Vijande et al. point out that the dosimetric characterizations carried out with the various MC codes should be provided independently. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  12. Automation system for quality control in manufacture of iodine-125 sealed sources used in brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Somessari, Samir L.; Feher, Anselmo; Sprenger, Francisco E.; Rostellato, Maria E.C.M.; Moura, Joao A.; Costa, Osvaldo L.; Calvo, Wilson A.P., E-mail: somessar@ipen.b, E-mail: afeher@ipen.b, E-mail: sprenger@ipen.b, E-mail: elisaros@ipen.b, E-mail: olcosta@ipen.b, E-mail: wapcalvo@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The objective of this work is to develop an automation system for Quality Control in the production of Iodine-125 sealed sources, after undergoing the process of laser beam welding. These sources, also known as Iodine-125 seeds are used, successfully, in the treatment of cancer by brachytherapy, with low-dose rates. Each small seed is composed of a welded titanium capsule with 0.8 mm diameter and 4.5 mm in length, containing Iodine-125 adsorbed on an internal silver wire. The seeds are implanted in the human prostate to irradiate the tumor and treat the cancerous cells. The technology to automate the quality control system in the manufacture of Iodine-125 seeds consists in developing and associate mechanical parts, electronic components and pneumatic circuits to control machines and processes. The automation technology for Iodine-125 seed production developed in this work employs programmable logic controller, step motors, drivers of control, electrical-electronic interfaces, photoelectric sensors, interfaces of communication and software development. Industrial automation plays an important role in the production of Iodine-125 seeds, with higher productivity and high standard of quality, facilitating the implementation and operation of processes with good manufacturing practices. Nowadays, the Radiation Technology Center at IPEN-CNEN/SP imports and distributes 36,000 Iodine-125 seeds per year for clinics and hospitals in the whole country. However, the Brazilian potential market is of 8,000 Iodine-125 seeds per month. Therefore, the local production of these radioactive seeds has become a priority for the Institute, aiming to reduce the price and increase the supply to the population in Brazil. (author)

  13. Automation system for quality control in manufacture of iodine-125 sealed sources used in brachytherapy

    International Nuclear Information System (INIS)

    Somessari, Samir L.; Feher, Anselmo; Sprenger, Francisco E.; Rostellato, Maria E.C.M.; Moura, Joao A.; Costa, Osvaldo L.; Calvo, Wilson A.P.

    2011-01-01

    The objective of this work is to develop an automation system for Quality Control in the production of Iodine-125 sealed sources, after undergoing the process of laser beam welding. These sources, also known as Iodine-125 seeds are used, successfully, in the treatment of cancer by brachytherapy, with low-dose rates. Each small seed is composed of a welded titanium capsule with 0.8 mm diameter and 4.5 mm in length, containing Iodine-125 adsorbed on an internal silver wire. The seeds are implanted in the human prostate to irradiate the tumor and treat the cancerous cells. The technology to automate the quality control system in the manufacture of Iodine-125 seeds consists in developing and associate mechanical parts, electronic components and pneumatic circuits to control machines and processes. The automation technology for Iodine-125 seed production developed in this work employs programmable logic controller, step motors, drivers of control, electrical-electronic interfaces, photoelectric sensors, interfaces of communication and software development. Industrial automation plays an important role in the production of Iodine-125 seeds, with higher productivity and high standard of quality, facilitating the implementation and operation of processes with good manufacturing practices. Nowadays, the Radiation Technology Center at IPEN-CNEN/SP imports and distributes 36,000 Iodine-125 seeds per year for clinics and hospitals in the whole country. However, the Brazilian potential market is of 8,000 Iodine-125 seeds per month. Therefore, the local production of these radioactive seeds has become a priority for the Institute, aiming to reduce the price and increase the supply to the population in Brazil. (author)

  14. Experimental determination of the TG-43 dosimetric characteristics of EchoSeedTM model 6733 125I brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, A.S.; Dini, Sharifeh A.; Sowards, Keith; Hayes, Joshua L.; Al-Otoom, Awni

    2002-01-01

    Recently an improved design of a 125 I brachytherapy source has been introduced for interstitial seed implants, particularly for prostate seed implants. This design improves the in situ ultrasound visualization of the source compared to the conventional seed. In this project, the TG-43 recommended dosimetric characteristics of the new brachytherapy source have been experimentally determined in Solid Water trade mark sign phantom material. The measured dosimetric characteristics of the new source have been compared with data reported in the literature for other source designs. The measured dose rate constant, Λ, in Solid Water was multiplied by 1.05 to extract the dose rate constant in water. The dose rate constant of the new source in water was found to be 0.99±8% cGy h -1 U -1 . The radial dose function was measured at distances between 0.5 and 10 cm using LiF TLDs in Solid Water trade mark sign phantom. The anisotropy function, F(r,θ), was measured at distances of 2, 3, 5, and 7 cm

  15. Study of dose distributions in voxel phantoms for brachytherapy sources using the GEANT4 Monte Carlo toolkit

    International Nuclear Information System (INIS)

    Martins, Maximiano C.; Santos, Denison S.; Queiroz Filho, Pedro P. de; Begalli, Marcia

    2009-01-01

    This work studies the effects of corrections in the calculation of dose distribution for brachytherapy sources when they are inserted in a male human voxel phantom. The sources studied here are the Best Industries 125 I 2301 model for low dose rate and the Amersham Buchler G0814 model 192 Ir seed for high dose rate, in the simulation of prostate treatments. The presence of organs around the interest point scatters radiation in a different form than a water cube, the situation that is usually configured in these calculations. The insertion of the sources in an anthropomorphic phantom brings results closer to the real situation. The chosen phantom was the head and torso voxel phantom created by Zubal. The Geant4 Monte Carlo toolkit was used to simulate the radiation transportation along the source shielding and the human organs of the voxel phantom. After inserting the source in the phantom, the energy deposition in each voxel is computed, allowing the construction of isodose curves. The source insertion in the anthropomorphic phantom aims also at a further knowledge about the brachytherapy treatment planning and additional information such as the target volume dose and in neighbor organs, data that will be useful for medical staff working with this technique. (author)

  16. Robustness to source displacement in dual air kerma strength planning for focal low-dose-rate brachytherapy of prostate cancer.

    Science.gov (United States)

    Mahdavi, S Sara; Spadinger, Ingrid T; Chng, Nicholas T; Morris, W James

    2016-01-01

    To describe the use of dual source strength implants for focal low-dose-rate brachytherapy. An interneedle dual source strength planning strategy is described for focal low-dose-rate brachytherapy of the prostate. The implanted treatment plans were designed using peripheral (except near the rectum) needles loaded with high strength (0.9 U) sources and central needles loaded with low strength (0.4 U) sources ("interneedle" dual strength planning). This approach has been applied for focally treating 3 patients. In this article, we compare the characteristics and robustness to source motion of interneedle dual strength planning with four alternative planning strategies (single strength high, low, and intermediate, and intraneedle dual strength) on 50 simulated cases. Interneedle dual source strength planning results in greater robustness to source motion and overall lower seed and needle density compared to the standard low source strength planning currently used in our centre. This planning approach is also significantly superior to single strength high, single strength intermediate and intraneedle dual strength planning strategies in terms of high dose to the urethral avoidance structure. The use of interneedle dual source strength treatment plans for focal low-dose-rate brachytherapy is possibly the practical solution for limiting the density of sources required to deliver the prescribed dose while limiting proximity of high strength sources to organs at risk. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  17. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co

    International Nuclear Information System (INIS)

    Reed, J. L.; Micka, J. A.; Culberson, W. S.; DeWerd, L. A.; Rasmussen, B. E.; Davis, S. D.

    2014-01-01

    Purpose: To determine the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters (TLD-100) for 125 I and 103 Pd brachytherapy sources relative to 60 Co. Methods: LiF:Mg,Ti TLDs were irradiated with low-energy brachytherapy sources and with a 60 Co teletherapy source. The brachytherapy sources measured were the Best 2301 125 I seed, the OncoSeed 6711 125 I seed, and the Best 2335 103 Pd seed. The TLD light output per measured air-kerma strength was determined for the brachytherapy source irradiations, and the TLD light output per air kerma was determined for the 60 Co irradiations. Monte Carlo (MC) simulations were used to calculate the dose-to-TLD rate per air-kerma strength for the brachytherapy source irradiations and the dose to TLD per air kerma for the 60 Co irradiations. The measured and MC-calculated results for all irradiations were used to determine the TLD intrinsic energy dependence for 125 I and 103 Pd relative to 60 Co. Results: The relative TLD intrinsic energy dependences (relative to 60 Co) and associated uncertainties (k = 1) were determined to be 0.883 ± 1.3%, 0.870 ± 1.4%, and 0.871 ± 1.5% for the Best 2301 seed, OncoSeed 6711 seed, and Best 2335 seed, respectively. Conclusions: The intrinsic energy dependence of TLD-100 is dependent on photon energy, exhibiting changes of 13%–15% for 125 I and 103 Pd sources relative to 60 Co. TLD measurements of absolute dose around 125 I and 103 Pd brachytherapy sources should explicitly account for the relative TLD intrinsic energy dependence in order to improve dosimetric accuracy

  18. 10 CFR 35.490 - Training for use of manual brachytherapy sources.

    Science.gov (United States)

    2010-01-01

    ... Section 35.490 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Manual Brachytherapy... been recognized by the Commission or an Agreement State, and who meets the requirements in paragraph (b... competence in radiation safety, radionuclide handling, treatment planning, quality assurance, and clinical...

  19. Monte Carlo aided design of an improved well-type ionization chamber for low energy brachytherapy sources.

    Science.gov (United States)

    Bohm, Tim D; Micka, John A; DeWerd, Larry A

    2007-04-01

    The determination of the air kerma strength of a brachytherapy seed is necessary for effective treatment planning. Well-type ionization chambers are used on site at therapy clinics to determine the air kerma strength of seeds. In this work, an improved well-type ionization chamber for low energy, low dose rate brachytherapy sources is designed using Monte Carlo transport calculations to aid in the design process. The design improvements are the elimination of the air density induced over-response effect seen in other air-communicating chambers for low energy photon sources, and a larger signal strength (response or current) for 103Pd and 125I based seeds. A prototype well chamber based on the Monte Carlo aided design but using graphite coated acrylic walls rather than the design basis air equivalent plastic (C-552) walls was constructed and experimentally evaluated. The prototype chamber produced an 85% stronger signal when measuring a commonly used 103Pd seed and a 26% stronger signal when measuring a commonly used 125I seed when compared to another commonly used well chamber. The normalized PTP corrected chamber response is, at most, 1.3% and 2.4% over unity for air densities/pressures corresponding to an elevation of 3048 m (10000 feet) above sea level for the commonly used 103Pd and 125I based seeds respectively. Comparing calculated and measured chamber responses for common 103Pd and 125I based brachytherapy seeds show agreement within 0.6% and 0.2%, respectively. We conclude that Monte Carlo transport calculations accurately model the response of this new well chamber and in general can be used to predict the response of well chambers. The prototype chamber built in this work responds as predicted by the Monte Carlo calculations.

  20. Energy spectrum based calculation of the half and the tenth value layers for brachytherapy sources using a semiempirical parametrized mass attenuation coefficient formulism

    International Nuclear Information System (INIS)

    Yue, Ning J.

    2008-01-01

    As different types of radionuclides (e.g., 131 Cs source) are introduced for clinical use in brachytherapy, the question is raised regarding whether a relatively simple method exists for the derivation of values of the half value layer (HVL) or the tenth value layer (TVL). For the radionuclide that has been clinically used for years, such as 125 I and 103 Pd, the sources have been manufactured and marketed by several vendors with different designs and structures. Because of the nature of emission of low energy photons for these radionuclides, energy spectra of the sources are very dependent on their individual designs. Though values of the HVL or the TVL in certain commonly used shielding materials are relatively small for these low energy photon emitting sources, the question remains how the variations in energy spectra affect the HVL (or TVL) values and whether these values can be calculated with a relatively simple method. A more fundamental question is whether a method can be established to derive the HVL (TVL) values for any brachytherapy sources and for different materials in a relatively straightforward fashion. This study was undertaken to answer these questions. Based on energy spectra, a well established semiempirical mass attenuation coefficient computing scheme was utilized to derive the HVL (TVL) values of different materials for different types of brachytherapy sources. The method presented in this study may be useful to estimate HVL (TVL) values of different materials for brachytherapy sources of different designs and containing different radionuclides

  1. Separation of fission produced 106Ru from simulated high level nuclear wastes for production of brachytherapy sources

    International Nuclear Information System (INIS)

    Blicharska, Magdalena; Bartoś, Barbara; Krajewski, Seweryn; Bilewicz, Aleksander

    2014-01-01

    Brachytherapy is the common method for treating various tumors, and currently 106 Ru and 125 I applicators are the most frequently used. Considering that 106 Ru is a β emitter with maximum energy of 3.54 MeV, it is best indicated in the treatment of small melanomas, with up to 20 mm tissue range. 106 Ru is commercially obtained from neutron irradiated high enrichment 235 U target in process of production 99 Mo. At present, there are only a handful of ageing reactors worldwide capable of producing the 99 Mo, therefore alternative strategies for production of this key medical isotope are explored. In our work, we propose to use liquid high-level radioactive waste as a source of high activity of 106 Ru. Simple calculations indicate that 1 dm 3 of HLLW solution after 4 years of cooling contains about 500 GBq of 106 Ru. This amount of activity is enough for production of about few thousands of brachytherapy sources. Present communication reports results of our process development studies on the recovery of ruthenium radioisotopes from simulated solution of high level radioactive waste using oxidation-extraction method

  2. A fibre optic scintillator dosemeter for absorbed dose measurements of low-energy X-ray-emitting brachytherapy sources

    International Nuclear Information System (INIS)

    Sliski, A.; Soares, C.; Mitch, M. G.

    2006-01-01

    A newly developed dosemeter using a 0.5 mm diameter x 0.5 mm thick cylindrical plastic scintillator coupled to the end of a fibre optic cable is capable of measuring the absorbed dose rate in water around low-activity, low-energy X-ray emitters typically used in prostate brachytherapy. Recent tests of this dosemeter showed that it is possible to measure the dose rate as a function of distance in water from 2 to 30 mm of a 103 Pd source of air-kerma strength 3.4 U (1 U = 1 μGy m 2 h -1 ), or 97 MBq (2.6 mCi) apparent activity, with good signal-to-noise ratio. The signal-to-noise ratio is only dependent on the integration time and background subtraction. The detector volume is enclosed in optically opaque, nearly water-equivalent materials so that there is no polar response other than that due to the shape of the scintillator volume chosen, in this case cylindrical. The absorbed dose rate very close to commercial brachytherapy sources can be mapped in an automated water phantom, providing a 3-D dose distribution with sub-millimeter spatial resolution. The sensitive volume of the detector is 0.5 mm from the end of the optically opaque waterproof housing, enabling measurements at very close distances to sources. The sensitive detector electronics allow the measurement of very low dose rates, as exist at centimeter distances from these sources. The detector is also applicable to mapping dose distributions from more complex source geometries such as eye applicators for treating macular degeneration. (authors)

  3. Comparison of192Ir,169Yb, and60Co high-dose rate brachytherapy sources for skin cancer treatment.

    Science.gov (United States)

    Safigholi, Habib; Meigooni, Ali S; Song, William Y

    2017-09-01

    To evaluate the possibility of utilizing the high-dose rate (HDR) 169 Yb and 60 Co sources, in addition to 192 Ir, for the treatment of skin malignancies with conical applicators. Monte Carlo (MC) simulations were used to benchmark the dosimetric parameters of single 169 Yb (4140), 60 Co (Co0.A86), and 192 Ir (mHDR-V2) brachytherapy sources in a water phantom and compared their results against published data. A standard conical tungsten alloy Leipzig-style applicator (Stand.Appl) was used for determination of the dose distributions at various depths with a single dwell position of the HDR sources. The HDR sources were modeled with its long axis parallel to the treatment plane within the opening section of the applicator. The source-to-surface distance (SSD) was 1.6 cm, which included a 0.1 cm thick removable plastic end-cap used for clinical applications. The prescription depth was considered to be 0.3 cm in a water phantom following the definitions in the literature for this treatment technique. Dose distributions generated with the Stand.Appl and the 169 Yb and 60 Co sources have been compared with those of the 192 Ir source, for the same geometry. Then, applicator wall thickness for the 60 Co source was increased (doubled) in MC simulations in order to minimize the leakage dose and penumbra to levels that were comparable to that from the 192 Ir source. For each source-applicator combination, the optimized plastic end-cap dimensions were determined in order to avoid over-dosage to the skin surface. The normalized dose profiles at the prescription depth for the 169 Yb-Stand.Appl and the 60 Co-double-wall applicator were found to be similar to that of the 192 Ir-Stand.Appl, with differences Ir-, 169 Yb- and 60 Co-Stand.Appl were found to be comparable to the values with the 60 Co-double-walled applicator, with differences Ir-, 169 Yb-Stand.Appl, and 60 Co-double-wall applicators respectively. The leakage dose around the Stand.Appl for distance > 2 cm from the

  4. The non-uniformity correction factor for the cylindrical ionization chambers in dosimetry of an HDR 192Ir brachytherapy source

    Directory of Open Access Journals (Sweden)

    Majumdar Bishnu

    2006-01-01

    Full Text Available The aim of this study is to derive the non-uniformity correction factor for the two therapy ionization chambers for the dose measurement near the brachytherapy source. The two ionization chambers of 0.6 cc and 0.1 cc volume were used. The measurement in air was performed for distances between 0.8 cm and 20 cm from the source in specially designed measurement jig. The non-uniformity correction factors were derived from the measured values. The experimentally derived factors were compared with the theoretically calculated non-uniformity correction factors and a close agreement was found between these two studies. The experimentally derived non-uniformity correction factor supports the anisotropic theory.

  5. Effect of inhomogeneities and source position on dose distribution of nucletron high dose rate Ir-192 brachytherapy source by Monte Carlo simulation

    Directory of Open Access Journals (Sweden)

    Chandola R

    2010-01-01

    Full Text Available Background: The presence of least dense dry air and highly dense cortical bone in the path of radiation and the position of source, near or far from the surface of patient, affects the exact dose delivery like in breast brachytherapy. Aim: This study aims to find out the dose difference in the presence of inhomogenieties like cortical bone and dry air as well as to find out difference of dose due to position of source in water phantom of high dose rate (HDR 192 Ir nucletron microselectron v2 (mHDRv2 brachytherapy source using Monte Carlo (MC simulation EGSnrc code, so that the results could be used in Treatment Planning System (TPS for more precise brachytherapy treatment. Settings and Design: The settings and design are done using different software of the computer. Methods and Materials: For this study, the said source, water phantom of volume 30 x 30 x 30 cm 3 , inhomogeneities each of volume 1 x 2 x 2 cm 3 with their position, water of water phantom and position of source are modeled using three-dimensional MC EGSnrc code. Statistical Analysis Used: Mean and probability are used for results and discussion. Results : The % relative dose difference is calculated here as 5.5 to 6.5% higher and 4.5 to 5% lower in the presence of air and cortical bone respectively at transverse axis of the source, which may be due to difference of linear attenuation coefficients of the inhomogeneities. However, when the source was positioned at 1 cm distance from the surface of water phantom, the near points between 1 to 2 cm and 3 to 8 cm. from the source, at its transverse axis, were 2 to 3.5% and 4 to 16% underdose to the dose when the source was positioned at mid-point of water phantom. This may be due to lack of back scatter material when the source was positioned very near to the surface of said water phantom and overlap of the additional cause of missing scatter component with the primary dose for near points from the source. These results were found in

  6. Radioactive waste evacuation of the sources of a low dose rate brachytherapy unit

    International Nuclear Information System (INIS)

    Serrada, A.; Huerga, C.; Santa Olalla, I.; Vicedo, A.; Corredoira, E.; Plaza, R.; Vidal, J.; Tellez, M.

    2006-01-01

    Introduction The second class Radioactive Installation start -up authorization makes responsible for its security to the installation exploiter and supervisor. The specifications established in the authorization, which are mandatory, point out several actions, some of these actions are the hermeticity tests of radioactive sources an radiologic controls of environment dosimetry. It is necessary to optimize the time spent in each activity, managing them as reasonably as possible. An important matter to take into account is to keep and control only those radioactive or radiological equipment which, even if are in work, have an appropriate performance for the patient treatment Material And Method a Paz hospital has an intracavity brachytherapy (L.D.R.), Curietron model. The Radioprotection Department proposed to remove from service the unit due to its age, this was carried out by the Commission of Guarantee and Quality Control. There were different solutions taken into account to decommission the unit, finally the option chosen as the most convenient for the installation was to manage directly the withdrawal of the radioactive material which consisted of seven Cs-137 probes model CsM1 and total nominal certificated activity of 7770 MBq ( 210 mCi ) dated in May 2005. It also has to be considered as a radioactive waste the inner storage elements of the Curietron and the transport and storage curie stock, built with depleted uranium. To accomplish this aim an evacuation container was designed consisting of an alloy of low-melting point (M.C.P.96), which fulfills the transport conditions imposed by E.N.R.E.S.A. ( Empresa Nacional de Residuos Radiactivos, S.A). A theoretical calculation was performed to estimate the thickness of the shield which adequate to the rate of dose in contact demanded. Accuracy of these calculations has been verified using T.L. dosimetry. Results The radiation levels during the extraction intervention of the radioactive probes and its transfer to

  7. Radioactive waste evacuation of the sources of a low dose rate brachytherapy unit

    Energy Technology Data Exchange (ETDEWEB)

    Serrada, A.; Huerga, C.; Santa Olalla, I.; Vicedo, A.; Corredoira, E.; Plaza, R.; Vidal, J.; Tellez, M. [La Paz Hospital, Madrid (Spain)

    2006-07-01

    Introduction The second class Radioactive Installation start -up authorization makes responsible for its security to the installation exploiter and supervisor. The specifications established in the authorization, which are mandatory, point out several actions, some of these actions are the hermeticity tests of radioactive sources an radiologic controls of environment dosimetry. It is necessary to optimize the time spent in each activity, managing them as reasonably as possible. An important matter to take into account is to keep and control only those radioactive or radiological equipment which, even if are in work, have an appropriate performance for the patient treatment Material And Method a Paz hospital has an intracavity brachytherapy (L.D.R.), Curietron model. The Radioprotection Department proposed to remove from service the unit due to its age, this was carried out by the Commission of Guarantee and Quality Control. There were different solutions taken into account to decommission the unit, finally the option chosen as the most convenient for the installation was to manage directly the withdrawal of the radioactive material which consisted of seven Cs-137 probes model CsM1 and total nominal certificated activity of 7770 MBq ( 210 mCi ) dated in May 2005. It also has to be considered as a radioactive waste the inner storage elements of the Curietron and the transport and storage curie stock, built with depleted uranium. To accomplish this aim an evacuation container was designed consisting of an alloy of low-melting point (M.C.P.96), which fulfills the transport conditions imposed by E.N.R.E.S.A. ( Empresa Nacional de Residuos Radiactivos, S.A). A theoretical calculation was performed to estimate the thickness of the shield which adequate to the rate of dose in contact demanded. Accuracy of these calculations has been verified using T.L. dosimetry. Results The radiation levels during the extraction intervention of the radioactive probes and its transfer to

  8. Photon spectrometry for the determination of the dose-rate constant of low-energy photon-emitting brachytherapy sources

    International Nuclear Information System (INIS)

    Chen, Zhe Jay; Nath, Ravinder

    2007-01-01

    Accurate determination of dose-rate constant (Λ) for interstitial brachytherapy sources emitting low-energy photons (<50 keV) has remained a challenge in radiation dosimetry because of the lack of a suitable absolute dosimeter for accurate measurement of the dose rates near these sources. Indeed, a consensus value of Λ taken as the arithmetic mean of the dose-rate constants determined by different research groups and dosimetry techniques has to be used at present for each source model in order to minimize the uncertainties associated with individual determinations of Λ. Because the dosimetric properties of a source are fundamentally determined by the characteristics of the photons emitted by the source, a new technique based on photon spectrometry was developed in this work for the determination of dose-rate constant. The photon spectrometry technique utilized a high-resolution gamma-ray spectrometer to measure source-specific photon characteristics emitted by the low-energy sources and determine their dose-rate constants based on the measured photon-energy spectra and known dose-deposition properties of mono-energetic photons in water. This technique eliminates many of the difficulties arising from detector size, the energy dependence of detector sensitivity, and the use of non-water-equivalent solid phantoms in absolute dose rate measurements. It also circumvents the uncertainties that might be associated with the source modeling in Monte Carlo simulation techniques. It was shown that the estimated overall uncertainty of the photon spectrometry technique was less than 4%, which is significantly smaller than the reported 8-10% uncertainty associated with the current thermo-luminescent dosimetry technique. In addition, the photon spectrometry technique was found to be stable and quick in Λ determination after initial setup and calibration. A dose-rate constant can be determined in less than two hours for each source. These features make it ideal to determine

  9. HDR and PDR192Ir source activity control procedures, as the part of the quality assurance system at Brachytherapy Department of Greater Poland Cancer Centre.

    Science.gov (United States)

    Zwierzchowski, Grzegorz; Błasiak, Barbara; Stefaniak, Patrycja; Bielęda, Grzegorz

    2009-10-01

    One of the main causes of treatment failures in brachytherapy is incorrect source strength specification in planning system or treatment delivery console. Source strength control is the only scheme to avoid such mistakes. The main aim of this work was to present results of three years of HDR and PDR sources activity control. Study was based on data from 14 192 Ir HDR and PDR sources exchanges. Sources were checked three times: at the exchange day and after one and two months. Measurements were performed twice with thimble chamber (PMMA phantom), and well chamber. The source strength were measured as air - kerma and recalculated to activity. Source activities measured using well chamber and thimble chamber, as well as activities provided by planning system, were presented for PDR and HDR, respectively. Differences between results obtained using each chamber and activities from planning system were presented graphically. The calculated and measured activities differed less than 5%. Wilcoxon test was performed as well, no statistically significant differences were observed among HDR or PDR activities. Checking of source parameters is one of the most important parts of quality control system in brachytherapy facilities. Well chamber and thimble chamber based dosimetry systems are fast and reliable tools for 192 Ir source parameters checking in working brachytherapy department conditions.

  10. Mechanical Design of the Radio-Isotope Source Driver Module for an Initial Prototype of Medium Dose Rate Brachytherapy

    International Nuclear Information System (INIS)

    Ari Satmoko; Tri Harjanto; Hendra Prasetia

    2012-01-01

    High dose rate brachytherapy equipment for therapy against cervical cancer is developed by empowering local products. An Iridium-192 with 5 Curies of energy is used. The source is wrapped in a capsule and combined with a wire diameter of 1 mm and length 1800 mm. The therapy is carried out by inserting the radiation source into the patient's body through an applicator. The system for loading-unloading the isotope source is divided into three modules: the source driver module, the source container modules, and channel distributor module. In this paper, the discussion is focused on engineering activities of the first module that serves to drive forward and backward position of the Iridium-192 isotope sources. The activity begins with the development of preliminary design sketches that produces drawings of mechanical components required. Furthermore, the calculations are carried out in order to establish the main component specifications. From this stage, a stepper motor type M66-A50K-G10 as a mechanical driver is chosen. The next stage is developing the detailed design and producing detailed drawings for all components. The fabrication of each component refers to the detailed design drawings. All components are assembled completely into the source driver module. Test also shows that the module works manually well. By rotating the manual handle in both directions, the tip of the wire moves alternately in forward and backward directions. (author)

  11. Calibration of photon and beta ray sources used in brachytherapy. Guidelines on standardized procedures at Secondary Standards Dosimetry Laboratories (SSDLs) and hospitals

    International Nuclear Information System (INIS)

    2002-03-01

    It has generally been recognized that international harmonization in radiotherapy dosimetry is essential. Consequently, the IAEA has given much effort to this, for example by publishing a number of reports in the Technical Reports Series (TRS) for external beam dosimetry, most notably TRS-277 and more recently TRS-398. Both of these reports describe in detail the steps to be taken for absorbed dose determination in water and they are often referred to as 'dosimetry protocols'. Similar to TRS-277, it is expected that TRS-398 will be adopted or used as a model by a large number of countries as their national protocol. In 1996, the IAEA established a calibration service for low dose rate (LDR) 137 Cs brachytherapy sources, which is the most widely used source for treatment of gynecological cancer. To further enhance harmonization in brachytherapy dosimetry, the IAEA published in 1999 IAEA-TECDOC-1079 entitled 'Calibration of Brachytherapy Sources. Guidelines on Standardized Procedures for the Calibration of Brachytherapy Sources at Secondary Standard Dosimetry Laboratories (SSDLs) and Hospitals'. The report was well received and was distributed in a large number of copies to the members of the IAEA/WHO network of SSDLs and to medical physicists working with brachytherapy. The present report is an update of the aforementioned TECDOC. Whereas TECDOC-1079 described methods for calibrating brachytherapy sources with photon energies at or above those of 192 Ir, the current report has a wider scope in that it deals with standardization of calibration of all the most commonly used brachytherapy sources, including both photon and beta emitting sources. The latter sources have been in use for a few decades already, but their calibration methods have been unclear. Methods are also described for calibrating sources used in the rapidly growing field of cardiovascular angioplasty. In this application, irradiation of the vessel wall is done in an attempt to prevent restenosis after

  12. Evaluation of Wall Correction Factor of INER's Air-Kerma Primary Standard Chamber and Dose Variation by Source Displacement for HDR 192Ir Brachytherapy

    Directory of Open Access Journals (Sweden)

    J. H. Lee

    2013-01-01

    Full Text Available The aim of the present study was to estimate the wall effect of the self-made spherical graphite-walled cavity chamber with the Monte Carlo method for establishing the air-kerma primary standard of high-dose-rate (HDR 192Ir brachytherapy sources at the Institute of Nuclear Energy Research (INER, Taiwan. The Monte Carlo method established in this paper was also employed to respectively simulate wall correction factors of the 192Ir air-kerma standard chambers used at the National Institute of Standards and Technology (NIST, USA and the National Physical Laboratory (NPL, UK for comparisons and verification. The chamber wall correction calculation results will be incorporated into INER's HDR 192Ir primary standard in the future. For the brachytherapy treatment in the esophagus or in the bronchi, the position of the isotope may have displacement in the cavity. Thus the delivered dose would differ from the prescribed dose in the treatment plan. We also tried assessing dose distribution due to the position displacement of HDR 192Ir brachytherapy source in a phantom with a central cavity by the Monte Carlo method. The calculated results could offer a clinical reference for the brachytherapy within the human organs with cavity.

  13. Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques.

    Science.gov (United States)

    Palmer, Antony; Bradley, David; Nisbet, Andrew

    2012-06-01

    This study provides a review of recent publications on the physics-aspects of dosimetric accuracy in high dose rate (HDR) brachytherapy. The discussion of accuracy is primarily concerned with uncertainties, but methods to improve dose conformation to the prescribed intended dose distribution are also noted. The main aim of the paper is to review current practical techniques and methods employed for HDR brachytherapy dosimetry. This includes work on the determination of dose rate fields around brachytherapy sources, the capability of treatment planning systems, the performance of treatment units and methods to verify dose delivery. This work highlights the determinants of accuracy in HDR dosimetry and treatment delivery and presents a selection of papers, focusing on articles from the last five years, to reflect active areas of research and development. Apart from Monte Carlo modelling of source dosimetry, there is no clear consensus on the optimum techniques to be used to assure dosimetric accuracy through all the processes involved in HDR brachytherapy treatment. With the exception of the ESTRO mailed dosimetry service, there is little dosimetric audit activity reported in the literature, when compared with external beam radiotherapy verification.

  14. Proposal for radioactive liquid waste management in a brachytherapy sealed sources development laboratory

    International Nuclear Information System (INIS)

    Souza, C.D.; Peleias Jr, F.S.; Rostelato, M.E.C.M.; Zeituni, C.A.; Benega, M.A.G.; Tiezzi, R.; Mattos, F.R.; Rodrigues, B.T.; Oliveira, T.B.; Feher, A.; Moura, J.A.; Costa, O.L.

    2014-01-01

    The radioactive waste management is addressed in several regulations. Literature survey indicates limited guidance on liquid waste management in Brachytherapy I-125 seeds production. Laboratories for those seeds are under implementation not only in Brazil but in several countries such as Poland, South Korea, Iran, China, and others. This paper may be used as reference to these other groups. For the correct implementation, a plan for radiological protection that has the management of radioactive waste fully specified is necessary. The proposal is that the waste will be deposited in a 20 L and 60 L containers which will take 2 years to fill. For glove box 1, the final activity of this container is 1.91 x 10 10 Bq (3.19 years to safe release in the environment). For glove box 3, the final activity of this container is 1.28 x 10 10 Bq (2.85 years to safe release in the environment). (authors)

  15. Monte Carlo simulations and radiation dosimetry measurements of 142Pr capillary tube-based radioactive implant (CTRI). A new structure for brachytherapy sources

    International Nuclear Information System (INIS)

    Bakht, M.K.; Haddadi, A.; Sadeghi, M.; Ahmadi, S.J.; Sadjadi, S.S.; Tenreiro, C.

    2013-01-01

    Previously, a promising β - -emitting praseodymium-142 glass seed was proposed for brachytherapy of prostate cancer. In accordance with the previous study, a 142 Pr capillary tube-based radioactive implant (CTRI) was suggested as a source with a new structure to enhance application of β - -emitting radioisotopes such as 142 Pr in brachytherapy. Praseodymium oxide powder was encapsulated in a glass capillary tube. Then, a thin and flexible fluorinated ethylene propylene Teflon layer sealed the capillary tube. The source was activated in the Tehran Research Reactor by the 141 Pr(n, γ) 142 Pr reaction. Measurements of the dosimetric parameters were performed using GafChromic radiochromic film. In addition, the dose rate distribution of 142 Pr CTRI was calculated by modeling 142 Pr source in a water phantom using Monte Carlo N-Particle Transport (MCNP5) Code. The active source was unreactive and did not leak in water. In comparison with the earlier proposed 142 Pr seed, the suggested source showed similar desirable dosimetric characteristics. Moreover, the 142 Pr CTRI production procedure may be technically and economically more feasible. The mass of praseodymium in CTRI structure could be greater than that of the 142 Pr glass seed; therefore, the required irradiation time and the neutron flux could be reduced. A 142 Pr CTRI was proposed for brachytherapy of prostate cancer. The dosimetric calculations by the experimental measurements and Monte Carlo simulation were performed to fulfill the requirements according to the American Association of Physicists in Medicine recommendations before the clinical use of new brachytherapy sources. The characteristics of the suggested source were compared with those of the previously proposed 142 Pr glass seed. (author)

  16. Study of dosimetric parameters for iodine-125 brachytherapy sources development from IPEN-CNEN/SP using Monte Carlo method

    International Nuclear Information System (INIS)

    Oliveira, Tiago Batista de

    2016-01-01

    Expectations of the World Health Organization for the year 2030 are that the number of cancer deaths is approximately 13.2 million, reflecting the high proportion of this disease in global health issue. With respect to prostate cancer, according to the National Cancer Institute, the number of cases diagnosed worldwide in 2012 was approximately 1.1 million, while in Brazil the data demonstrated the incidence of 68,000 new cases. The treatment of cancer can be performed with surgery (prostatectomy) or radiation therapy. Among radiotherapy, we can highlight the brachytherapy technique, which consists in the introduction of small radioactive sources (seeds) within the prostate, which is delivered a high dose value in the treatment volume and low dose in the surrounding tissues. In Brazil, the medical profession estimates a demand of approximately 8000 seeds / month, and the unit cost of each seed at least US $ 26.00. The AAPM protocol TG-43 recommend the dose-rate constant, radial dose function and anisotropy function for dosimetric analysis LDR brachytherapy seeds. In this work, Monte Carlo simulations were performed in order to assess the dosimetric parameters of the OncoSeed-6711, manufactured by Oncura-GEHealthcare, and a seed developed by Radiation Technology Center, using the MCNP5 code. A 6711 seed, an IPEN seed and the 30 x 30 x 30cm 3 phantom filled with water were modeled to simulate the dose distribution. The 6711 seed parameters were compared with literature, and the results presented relative error less than 0.1% for Λ. In comparison with the 6711 seed, the IPEN model seed dosimetric parameters were similar, account the statistical uncertainty. (author)

  17. Characterization and storage of liquid wastes containing 125Iodine in the laboratory for production of brachytherapy sources - IPEN

    International Nuclear Information System (INIS)

    Carvalho, Vitória S.; Souza, Daiane C.B. de; Barbosa, Nayane K.O.; Rodrigues, Bruna T.; Nogueira, Beatriz R.; Costa, Osvaldo L. da; Zeituni, Carlos A.; Vicente, Roberto; Rostelato, Maria E.C.M.

    2017-01-01

    Radioactive sources of Iodine-125 for medical applications have been developed at the Institute for Energy and Nuclear Research (IPEN) to meet the growing demand for medical applications such as brachytherapy. A dedicated laboratory is already being implemented at IPEN. Part of the processes involved in the production of sealed sources generate radioactive wastes that despite the short half-life (<100 days) have radioactive activity above the levels of exemption established by the Brazilian National Nuclear Energy Commission. Therefore, these wastes should receive appropriate treatment and storage until they reach the levels of release into the environment. This work aims to determine the volumes of the liquid wastes generated during the production stages of the sources, as well as to propose a temporary storage system for such wastes. The applied methodology consisted in determining the volumes of wastes generated in each production cell according to the manufacturing steps. After that, activities and activity concentrations were calculated for each container used for temporary storage inside the production laboratory. The total volume stored for one year in the temporary storage, as well as the rate of entry and exit of the liquid wastes were calculated according to the source production demand and the decay time of the radionuclide, respectively. The main results showed that the time required to reach sanitary sewage disposal values is within the period of operation of the facility. The total volume generated is also within the facility's temporary storage capacity

  18. A study on the dose distributions in various materials from an Ir-192 HDR brachytherapy source.

    Directory of Open Access Journals (Sweden)

    Shih-Ming Hsu

    Full Text Available Dose distributions of (192Ir HDR brachytherapy in phantoms simulating water, bone, lung tissue, water-lung and bone-lung interfaces using the Monte Carlo codes EGS4, FLUKA and MCNP4C are reported. Experiments were designed to gather point dose measurements to verify the Monte Carlo results using Gafchromic film, radiophotoluminescent glass dosimeter, solid water, bone, and lung phantom. The results for radial dose functions and anisotropy functions in solid water phantom were consistent with previously reported data (Williamson and Li. The radial dose functions in bone were affected more by depth than those in water. Dose differences between homogeneous solid water phantoms and solid water-lung interfaces ranged from 0.6% to 14.4%. The range between homogeneous bone phantoms and bone-lung interfaces was 4.1% to 15.7%. These results support the understanding in dose distribution differences in water, bone, lung, and their interfaces. Our conclusion is that clinical parameters did not provide dose calculation accuracy for different materials, thus suggesting that dose calculation of HDR treatment planning systems should take into account material density to improve overall treatment quality.

  19. Stem effect of a Ce3+ doped SiO2 optical dosimeter irradiated with a 192Ir HDR brachytherapy source

    International Nuclear Information System (INIS)

    Carrara, Mauro; Tenconi, Chiara; Guilizzoni, Roberta; Borroni, Marta; Cavatorta, Claudia; Cerrotta, Annamaria; Fallai, Carlo; Gambarini, Grazia; Vedda, Anna; Pignoli, Emanuele

    2014-01-01

    Fiber-optic-coupled scintillation dosimeters are characterized by their small active volume if compared to other existing systems. However, they potentially show a greater stem effect, especially in external beam radiotherapy where the Cerenkov effect is not negligible. In brachytherapy, due to the lower energies and the shorter high dose range of the employed sources, the impact of the stem effect to the detector accuracy might be low. In this work, the stem effect of a Ce 3+ doped SiO 2 scintillation detector coupled to a SiO 2 optical fiber was studied for high dose rate brachytherapy applications. Measurements were performed in a water phantom at changing source-detector mutual positions. The same irradiations were performed with a passive optical fiber, which doesn't have the dosimeter at its end. The relative contribution of the passive fiber with respect to the uncorrected readings of the detector in each one of the investigated source dwell positions was evaluated. Furthermore, the dosimeter was calibrated both neglecting and correcting its response for the passive fiber readings. The obtained absolute dose measurements were then compared to the dose calculations resulting from the treatment planning system. Dosimeter uncertainties with and without taking into account the passive fiber readings were generally below 2.8% and 4.3%, respectively. However, a particular exception results when the source is positioned near to the optical fiber, where the detector underestimates the dose (−8%) or at source-detector longitudinal distances higher than 3 cm. The obtained results show that the proposed dosimeter might be adopted in high dose rate prostate brachytherapy with satisfactory accuracy, without the need for any stem effect correction. However, accuracy further improves by subtraction of the noise signal produced by the passive optical fiber. - Highlights: • A scintillation detector with 0.9 mm diameter was developed for in vivo dosimetry in

  20. Quantification of iodine in porous hydroxyapatite matrices for application as radioactive sources in brachytherapy

    Directory of Open Access Journals (Sweden)

    Kássio André Lacerda

    2007-07-01

    Full Text Available In this study, non-radioactive iodine was incorporated in two types of biodegradable hydroxyapatite-based porous matrices (HA and HACL through impregnation process from sodium iodine aqueous solutions with varying concentrations (0.5 and 1.0 mol/L . The results revealed that both systems presented a high capacity of incorporating iodine into their matrices. The quantity of incorporated iodine was measured through Neutron Activation Analysis (NAA. The porous ceramic matrices based on hydroxyapatite demonstrated a great potential for uses in low dose rate (LDR brachytherapy.Materiais cerâmicos porosos à base de compostos de fosfatos de cálcio (CFC vêm sendo estudados e desenvolvidos para várias aplicações biomédicas tais como implantes, sistemas para liberação de drogas e fontes radioativas para braquiterapia. Dois tipos de matrizes porosas biodegradáveis de hidroxiapatita (HA e HACL foram avaliadas em termos da capacidade de incorporação de iodo em suas estruturas. Resultados revelaram que as matrizes porosas a base de hidroxiapatita apresentaram alta capacidade de incorporar iodo em sua estrutura. A quantidade de iodo foi mensurada através da técnica de Análise por Ativação Nêutronica (AAN. As matrizes cerâmicas porosas à base de hidroxiapatita demostraram ter grande potencial para aplicação em braquiterapia de baixa taxa de dose (LDR - Low Dose Rate.

  1. Evaluation of the response of polymeric gel modified MAGIC-f using a clinical brachytherapy source and Monte Carlo simulation with package PENELOPE

    International Nuclear Information System (INIS)

    Quevedo, Ana Luiza; Nicolucci, Patricia; Borges, Leandro F.

    2016-01-01

    In this work a comparison of experimental and simulated relative doses of a clinical brachytherapy source was performed. A 5 x 5 x 7 cm 3 phantom with a modified MAGIC-f gel was irradiated using a clinical 192 Ir source and read using Magnetic Resonance Imaging. The Monte Carlo simulation package PENELOPE was used to simulate the dose distributions of the same radiation source. The dose distributions were obtained in two planes perpendicular to the source: one passing through the source's center and the other at 0.5 cm away from the source's center. The higher differences found between experimental and computational distributions were 12.5% at a point 0.62 cm from the source for the central plane and 8.6% at 1.3 cm from the source to the plane 0.5 cm away from the source's center. Considering the high dose gradient of these dose distributions, the results obtained show that the modified MAGIC-f gel is promising for brachytherapy dosimetry. (author)

  2. A 3D computer graphics approach to brachytherapy planning.

    Science.gov (United States)

    Weichert, Frank; Wawro, Martin; Wilke, Carsten

    2004-06-01

    Intravascular brachytherapy (IVB) can significantly reduce the risk of restenosis after interventional treatment of stenotic arteries, if planned and applied correctly. In order to facilitate computer-based IVB planning, a three-dimensional reconstruction of the stenotic artery based on intravascular ultrasound (IVUS) sequences is desirable. For this purpose, the frames of the IVUS sequence are properly aligned in space, possible gaps inbetween the IVUS frames are filled by interpolation with radial basis functions known from scattered data interpolation. The alignment procedure uses additional information which is obtained from biplane X-ray angiography performed simultaneously during the capturing of the IVUS sequence. After IVUS images and biplane angiography data are acquired from the patient, the vessel-wall borders and the IVUS catheter are detected by an active contour algorithm. Next, the twist (relative orientation) between adjacent IVUS frames is determined by a sequential triangulation method. The absolute orientation of each frame is established by a stochastic analysis based on anatomical landmarks. Finally, the reconstructed 3D vessel model is visualized by methods of combined volume and polygon rendering. The reconstruction is then used for the computation of the radiation-distribution within the tissue, emitted from a beta-radiation source. All these steps are performed during the percutaneous intervention.

  3. SU-E-T-232: Custom High-Dose-Rate Brachytherapy Surface Mold Applicators: The Importance Source to Skin Distance

    International Nuclear Information System (INIS)

    Park, S; Demanes, J; Kamrava, M

    2015-01-01

    Purpose: Surface mold applicators can be customized to fit irregular skin surfaces that are difficult to treat with other radiation therapy techniques. Optimal design of customized HDR skin brachytherapy is not well-established. We evaluated the impact of applicator thickness (source to skin distance) on target dosimetry. Methods: 27 patients had 34 treated sites: scalp 4, face 13, extremity 13, and torso 4. Custom applicators were constructed from 5–15 mm thick thermoplastic bolus molded over the skin lesion. A planar array of plastic brachytherapy catheters spaced 5–10 mm apart was affixed to the bolus. CT simulation was used to contour the target volume and to determine the prescription depth. Inverse planning simulated annealing followed by graphical optimization was used to plan and deliver 40–56 Gy in 8–16 fractions. Target coverage parameters (D90, Dmean, and V100) and dose uniformity (V110–200, D0.1cc, D1cc, and D2cc) were studied according to target depth (<5mm vs. ≥5mm) and applicator thickness (5–10mm vs. ≥10mm). Results: The average prescription depth was 4.2±1.5mm. The average bolus thickness was 9.2±2.4mm. The median CTV volume was 10.0 cc (0.2–212.4 cc). Similar target coverage was achieved with prescription depths of <5mm and ≥5mm (Dmean = 113.8% vs. 112.4% and D90 = 100.2% vs. 98.3%). The <5mm prescription depth plans were more uniform (D0.1cc = 131.8% vs. 151.8%). Bolus thickness <10mm vs. ≥10mm plans also had similar target coverage (Dmean = 118.2% vs. 110.7% and D90 = 100.1% vs. 99.0%). Applicators ≥10mm thick, however, provide more uniform target dosimetry (D0.1cc = 146.9% vs. 139.5%). Conclusion: Prescription depth is based upon the thickness of the lesion and upon the clinical needs of the patient. Applicators ≥10mm thick provide more dose uniformity than 5–10mm thick applicators. Applicator thickness is an important variable that should be considered during treatment planning to achieve optimal dose uniformity

  4. Study and methodology development for quality control in the production process of iodine-125 radioactive sealed sources applied to brachytherapy

    International Nuclear Information System (INIS)

    Moura, Joao Augusto

    2009-01-01

    Today cancer is the second cause of death by disease in several countries, including Brazil. Excluding skin cancer, prostate cancer is the most incident in the population. Prostate tumor can be treated by several ways, including brachytherapy, which consists in introducing sealed radioactive sources (Iodine - 125 seeds) inside the tumor. The target region of treatment receives a high radiation dose, but healthy neighbor tissues receive a significantly reduced radiation dose. The seed is made of a welding sealed titanium capsule, 0.8 mm external diameter and 4.5 mm length, enclosing a 0.5 mm diameter silver wire with Iodine-125 adsorbed. After welded, the seeds have to be submitted to a leak test to prevent any radioactive material release. The aims of this work were: (a) the study of the different leakage test methods applied to radioactive seeds and recommended by the ISO 997820, (b) the choice of the appropriate method and (c) the flowchart determination of the process to be used during the seeds production. The essays exceeded the standards with the use of ultra-sound during immersion and the corresponding benefits to leakage detection. Best results were obtained with the immersion in distilled water at 20 degree C for 24 hours and distilled water at 70 degree C for 30 minutes. These methods will be used during seed production. The process flowchart has all the phases of the leakage tests according to the sequence determined in the experiments. (author)

  5. Intravascular pulmonary metastases

    International Nuclear Information System (INIS)

    Shepard, J.A.O.; Moore, E.H.; Templeton, P.A.; McLoud, T.C.

    1988-01-01

    The diagnosis of intravascular metastatic tumor emboli to the lungs is rarely made. The authors present a characteristic radiographic finding of intravascular lung metastases that they observed in four patients with diagnoses or right atrial myoxoma, invasive renal cell carcinoma, invasive pelvic osteosarcoma, and recurrent pelvic chondrosarcoma. Substantiation of intravascular pulmonary metastases was achieved by means of autopsy, pulmonary artery biopsy, and surgical documentation of tumor invasion of the inferior vena cava or pelvic veins. In all four cases, chest computed tomography (CT) demonstrated branching, beaded opacities extending from the hila into the periphery of the lung in the distribution of pulmonary arteries. In one case, similar findings were observed in magnetic resonance (MR) images of the chest. Follow-up studies in three cases showed progressive enlargement and varicosity of the abnormal pulmonary artery consistent with proliferation of intravascular tumor. In the case of metastatic osteosarcoma, intraluminal ossification was also observed at CT. In three of four cases, pulmonary infarction was demonstrated in the distribution of the abnormal pulmonary arteries seen at CT as small, peripheral, wedge-shaped opacities. The demonstration of progressively dilated and beaded pulmonary arteries in patients with extrathoracic malignancies is suggestive of intravascular lung metastases, particularly when accompanied by peripheral infarction

  6. SU-E-T-284: Revisiting Reference Dosimetry for the Model S700 Axxent 50 KV{sub p} Electronic Brachytherapy Source

    Energy Technology Data Exchange (ETDEWEB)

    Hiatt, JR [Rhode Island Hospital, Providence, RI (United States); Rivard, MJ [Tufts University School of Medicine, Boston, MA (United States)

    2014-06-01

    Purpose: The model S700 Axxent electronic brachytherapy source by Xoft was characterized in 2006 by Rivard et al. The source design was modified in 2006 to include a plastic centering insert at the source tip to more accurately position the anode. The objectives of the current study were to establish an accurate Monte Carlo source model for simulation purposes, to dosimetrically characterize the new source and obtain its TG-43 brachytherapy dosimetry parameters, and to determine dose differences between the source with and without the centering insert. Methods: Design information from dissected sources and vendor-supplied CAD drawings were used to devise the source model for radiation transport simulations of dose distributions in a water phantom. Collision kerma was estimated as a function of radial distance, r, and polar angle, θ, for determination of reference TG-43 dosimetry parameters. Simulations were run for 10{sup 10} histories, resulting in statistical uncertainties on the transverse plane of 0.03% at r=1 cm and 0.08% at r=10 cm. Results: The dose rate distribution the transverse plane did not change beyond 2% between the 2006 model and the current study. While differences exceeding 15% were observed near the source distal tip, these diminished to within 2% for r>1.5 cm. Differences exceeding a factor of two were observed near θ=150° and in contact with the source, but diminished to within 20% at r=10 cm. Conclusions: Changes in source design influenced the overall dose rate and distribution by more than 2% over a third of the available solid angle external from the source. For clinical applications using balloons or applicators with tissue located within 5 cm from the source, dose differences exceeding 2% were observed only for θ>110°. This study carefully examined the current source geometry and presents a modern reference TG-43 dosimetry dataset for the model S700 source.

  7. Radiological protection on interstitial brachytherapy and dose determination and exposure rate of an Ir-192 source through the MCNP-4B

    International Nuclear Information System (INIS)

    Morales L, M.E.

    2006-01-01

    The present work was carried out in the Neurological Sciences Institute having as objective to determine the dose and the rate of exhibition of the sources of Iridium 192, Iodine 125 and Palladium 103; which are used to carry out implant in the Interstitial Brachytherapy according to the TG43. For it we carry out a theoretical calculation, its are defined in the enter file: the geometry, materials of the problem and the radiation source, etc; in the MCNP-4B Monte Carlo code, considering a punctual source and for the dose determination we simulate thermoluminescent dosemeters (TLD): at 5 cm, 50 cm, 100 cm and 200 cm of the source. Our purpose is to analyze the radioprotection measures that should take into account in this Institute in which are carried out brain biopsies using a Micro mar stereotactic mark, and in a near future with the collaboration of a doctor and a cuban physique seeks to be carried out the Interstitial Brachytherapy technique with sources of Ir-192 for patient with tumors like glioblastoma, astrocytoma, etc. (Author)

  8. 103Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design

    International Nuclear Information System (INIS)

    Rivard, Mark J.; Reed, Joshua L.; DeWerd, Larry A.

    2014-01-01

    Purpose: A new type of 103 Pd source (CivaString and CivaThin by CivaTech Oncology, Inc.) is examined. The source contains 103 Pd and Au radio-opaque marker(s), all contained within low-Z eff organic polymers that permit source flexibility. The CivaString source is available in lengths L of 10, 20, 30, 40, 50, and 60 mm, and referred to in the current study as CS10–CS60, respectively. A thinner design, CivaThin, has sources designated as CT10–CT60, respectively. The CivaString and CivaThin sources are 0.85 and 0.60 mm in diameter, respectively. The source design is novel and offers an opportunity to examine its interesting dosimetric properties in comparison to conventional 103 Pd seeds. Methods: The MCNP5 radiation transport code was used to estimate air-kerma rate and dose rate distributions with polar and cylindrical coordinate systems. Doses in water and prostate tissue phantoms were compared to determine differences between the TG-43 formalism and realistic clinical circumstances. The influence of Ti encapsulation and 2.7 keV photons was examined. The accuracy of superposition of dose distributions from shorter sources to create longer source dose distributions was also assessed. Results: The normalized air-kerma rate was not highly dependent onL or the polar angle θ, with results being nearly identical between the CivaString and CivaThin sources for common L. The air-kerma strength was also weakly dependent on L. The uncertainty analysis established a standard uncertainty of 1.3% for the dose-rate constant Λ, where the largest contributors were μ en /ρ and μ/ρ. The Λ values decreased with increasing L, which was largely explained by differences in solid angle. The radial dose function did not substantially vary among the CivaString and CivaThin sources for r ≥ 1 cm. However, behavior for r 103 Pd wells and Au markers, respectively. Dose distributions of both source types had minimal anisotropy in comparison to conventional 103 Pd seeds

  9. [Intravascular endothelioma (author's transl)].

    Science.gov (United States)

    Vanĕk, J

    1978-01-01

    A 76-year-old woman developed a slowly growing lesion over the right index and the adjacent part of the metacarpus. A cell proliferation filling up the skin veins was classified as intravascular endothelioma. This rather rare oncological entity with a good prognosis should be differentiated from peculiar pattern occasionally seen in organisation of thrombi as well as malignant endothelial tumours.

  10. Harmonic Intravascular Ultrasound

    NARCIS (Netherlands)

    M.E. Frijlink (Martijn)

    2006-01-01

    textabstractMedical ultrasound is a popular imaging modality in cardiology. Harmonic Imaging is a technique that has been shown to increase the image quality of diagnostic ultrasound at frequencies below 10 MHz. However, Intravascular Ultrasound, which is a technique to acoustically investigate

  11. Monte Carlo simulation of 252Cf brachytherapy sources and adherence to AAPM TG-43 dosimetry protocol

    International Nuclear Information System (INIS)

    Paredes, L.; Balcazar, M.; Azorin, J.; Francois, J.L.

    2007-01-01

    Full text: The AAPM TG-43 dosimetry protocol was used for the calculation of the neutron absorbed dose rate from 252 Cf sources in some media for medical applications; a) Tissue substitute materials: water, A-150 plastic and b) Normal tissue: muscle (skeletal), brain. Monte Carlo MNCPX code was employed to characterize the neutron dosimetry in the vicinity of three 252 Cf sources, using the Maxwell fission neutron energy spectrum. The neutron air kerma rate is obtained with the +F6 heating tally to estimate the total energy deposition per mass unit of all particles in a spherical geometry of 200 cm in radius. Each set of evaluations required transport of 10 8 particle histories to achieve relative standard uncertainties 252 Cf sources, AT, Vari Source and μSelectron were simulated using the Monte Carlo MCNPX code in spherical geometry for the following factors: a) conversion coefficient of neutron air kerma strength, b) neutron dose rate constant, c) neutron radial dose function, d) geometry factor, e) anisotropy function and f) neutron absorbed dose rate. The simulations consider that neutrons were emitted isotropically and uniformly from a cylindrical active element of Pd:Cf 2 O 3 ceramic-metal matrix. The reference neutron dose rate in water at 1 cm and 90 degrees from the source long axis, using the Maxwell fission spectrum have been determined for the models AT, Vari Source and μSelectron: 1.8606±0.0003 c Gy h -1 μg -1 , 2.012±0.0003 c Gy h -1 μg -1 and 2.147±0.0003 c Gy h -1 μg -1 , respectively. (Author)

  12. Intravascular (catheter) MR imaging

    International Nuclear Information System (INIS)

    Cohen, A.M.; Hurst, G.C.; Katz, D.E.; Dverk, J.L.; Wiesen, E.J.; Czerski, L.W.; Malaya, R.; Bellon, E.M.

    1989-01-01

    Intravascular MR probes allow excellent spatial resolution and have the potential to detect arterial wall microstructure. Ultrasonic intravascular probes suggest that detailed morphologic information can assist clinical decision making. Catheter MR probes of 2--7 mm outside diameter (OD) were built of copper wire, Teflon, and parts from standard commercial catheters. The probes were connected to the surface coil receiver input of our Picker VISTA 2055HP 1.5-T imaging system. The extant (linear) body coil was used for transmit. Phantoms were constructed of coaxial glass MR tubes, filled with doped water. Watanabe rabbit aorta and human autopsy iliac artery specimens were examined within 4 hours of excision or stored by freezing. In vivo iliac arteries in dogs under general anesthesia were imaged, with percutaneous placement of the probe. Results are presented

  13. Assessment of a source position checking tool for the quality assurance of transfer tubes used in HDR 192Ir brachytherapy treatments.

    Science.gov (United States)

    Awunor, O A

    2018-01-15

    The determination of source positions before treatment is an essential part of the quality assurance (QA) associated with high dose rate brachytherapy treatments. The purpose of this study was to design and commission a tool to allow the quantification of source positions across multiple transfer tube types. A bespoke flexi-adapter jig, three transfer tube adapters, and a film piercing pointer were designed and built for source position QA across three transfer tube types-the standard, 6 French, and gynae transfer tubes. The jig was calibrated against a manufacturer source position check tool, and intratube and intertube source position variations investigated across a total of 40 transfer tubes, using strips of Gafchromic film irradiated at multiple positions 20 mm apart with a microSelectron V3 afterloader (Elekta, Holland). The performance of the jig in localizing the nominal dwell positions relative to the manufacturer check tool was assessed. Associated expanded uncertainties were quantified in line with the International Organization for Standardization Guidelines. The mean expanded uncertainty associated with the use of the jig was 0.4 ± 0.0 mm (k = 1). The performance of the jig was 0.3 ± 0.0 mm, while the intratube and intertube source positional variations were observed to be within ±1.0 mm across most transfer tubes. A bespoke flexi-adapter jig capable of allowing source position measurements to be carried out on various transfer tube types has been designed. Measurement results highlight the need for routine QA of all transfer tubes in clinical use. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  14. Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty

    International Nuclear Information System (INIS)

    Dijk, Eduard van; Kolkman-Deurloo, Inger-Karine K.; Damen, Patricia M. G.

    2004-01-01

    Different methods exist to determine the air kerma calibration factor of an ionization chamber for the spectrum of a 192 Ir high-dose-rate (HDR) or pulsed-dose-rate (PDR) source. An analysis of two methods to obtain such a calibration factor was performed: (i) the method recommended by [Goetsch et al., Med. Phys. 18, 462-467 (1991)] and (ii) the method employed by the Dutch national standards institute NMi [Petersen et al., Report S-EI-94.01 (NMi, Delft, The Netherlands, 1994)]. This analysis showed a systematic difference on the order of 1% in the determination of the strength of 192 Ir HDR and PDR sources depending on the method used for determining the air kerma calibration factor. The definitive significance of the difference between these methods can only be addressed after performing an accurate analysis of the associated uncertainties. For an NE 2561 (or equivalent) ionization chamber and an in-air jig, a typical uncertainty budget of 0.94% was found with the NMi method. The largest contribution in the type-B uncertainty is the uncertainty in the air kerma calibration factor for isotope i, N k i , as determined by the primary or secondary standards laboratories. This uncertainty is dominated by the uncertainties in the physical constants for the average mass-energy absorption coefficient ratio and the stopping power ratios. This means that it is not foreseeable that the standards laboratories can decrease the uncertainty in the air kerma calibration factors for ionization chambers in the short term. When the results of the determination of the 192 Ir reference air kerma rates in, e.g., different institutes are compared, the uncertainties in the physical constants are the same. To compare the applied techniques, the ratio of the results can be judged by leaving out the uncertainties due to these physical constants. In that case an uncertainty budget of 0.40% (coverage factor=2) should be taken into account. Due to the differences in approach between the

  15. Intravascular "mulberry-like" bodies

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Klebe, J G; Henriques, U V

    1988-01-01

    Intravascular "mulberry-like" bodies in a stillborn female infant with moderate maceration are reported. The histogenesis of these structures is discussed based on light-microscopic, immunohistochemical and ultrastructural findings. No demonstrable causal relation between the intravascular lesion...... and fetal death was found, the cause of death being attributed to intrauterine asphyxia. It is concluded, that intravascular "mulberry-bodies" most likely represent artifacts due to red blood cell autolysis....

  16. Definition study of the project Dosimetry Brachytherapy

    International Nuclear Information System (INIS)

    Bultman, J.

    1989-05-01

    The purpose of the research project Dosimetry Brachytherapy is the standardization of calibration methods and quality control procedures used for Brachytherapy sources. Proposals to develop measurement standards and methods for calibrating these sources are presented. Brachytherapy sources will be calibrated in terms of reference airkerma rate or in terms of absorbed dose in water. Therefore, in this project, special attention will be given to the in-phantom measurement method described by Meertens and the use of re-entrant ionisation chambers as transfer standards. In this report, a workplan and time schedule is included. (author). 19 refs.; 1 fig

  17. Direction modulated brachytherapy (DMBT) for treatment of cervical cancer: A planning study with192Ir,60Co, and169Yb HDR sources.

    Science.gov (United States)

    Safigholi, Habib; Han, Dae Yup; Mashouf, Shahram; Soliman, Abraam; Meigooni, Ali S; Owrangi, Amir; Song, William Y

    2017-12-01

    To evaluate plan quality of a novel MRI-compatible direction modulated brachytherapy (DMBT) tandem applicator using 192 Ir, 60 Co, and 169 Yb HDR brachytherapy sources, for various cervical cancer high-risk clinical target volumes (CTV HR ). The novel DMBT tandem applicator has six peripheral grooves of 1.3-mm diameter along a 5.4-mm thick nonmagnetic tungsten alloy rod. Monte Carlo (MC) simulations were used to benchmark the dosimetric parameters of the 192 Ir, 60 Co, and 169 Yb HDR sources in a water phantom against the literature data. 45 clinical cases that were treated using conventional tandem-and-ring applicators with 192 Ir source ( 192 Ir-T&R) were selected consecutively from intErnational MRI-guided BRAchytherapy in CErvical cancer (EMBRACE) trial. Then, for each clinical case, 3D dose distribution of each source inside the DMBT and conventional applicators were calculated and imported onto an in-house developed inverse planning optimization code to generate optimal plans. All plans generated by the DMBT tandem-and-ring (DMBT T&R) from all three sources were compared to the respective 192 Ir-T&R plans. For consistency, all plans were normalized to the same CTV HR D90 achieved in clinical plans. The D 2 cm3 for organs at risk (OAR) such as bladder, rectum, and sigmoid, and D90, D98, D10, V100, and V200 for CTV HR were calculated. In general, plan quality significantly improved when a conventional tandem (Con.T) is replaced with the DMBT tandem. The target coverage metrics were similar across 192 Ir-T&R and DMBT T&R plans with all three sources (P > 0.093). 60 Co-DMBT T&R generated greater hot spots and less dose homogeneity in the target volumes compared with the 192 Ir- and 169 Yb-DMBT T&R plans. Mean OAR doses in the DMBT T&R plans were significantly smaller (P Ir-T&R plans. Mean bladder D 2 cm3 was reduced by 4.07%, 4.15%, and 5.13%, for the 192 Ir-, 60 Co-, and 169 Yb-DMBT T&R plans respectively. Mean rectum (sigmoid) D 2 cm3 was reduced by 3

  18. Interstitial prostate brachytherapy. LDR-PDR-HDR

    International Nuclear Information System (INIS)

    Kovacs, Gyoergy; Hoskin, Peter

    2013-01-01

    The first comprehensive overview of interstitial brachytherapy for the management of local or locally advanced prostate cancer. Written by an interdisciplinary team who have been responsible for the successful GEC-ESTRO/EAU Teaching Course. Discusses in detail patient selection, the results of different methods, the role of imaging, and medical physics issues. Prostate brachytherapy has been the subject of heated debate among surgeons and the proponents of the various brachytherapy methods. This very first interdisciplinary book on the subject provides a comprehensive overview of innovations in low dose rate (LDR), high dose rate (HDR), and pulsed dose rate (PDR) interstitial brachytherapy for the management of local or locally advanced prostate cancer. In addition to detailed chapters on patient selection and the use of imaging in diagnostics, treatment guidance, and implantation control, background chapters are included on related medical physics issues such as treatment planning and quality assurance. The results obtained with the different treatment options and the difficult task of salvage treatment are fully discussed. All chapters have been written by internationally recognized experts in their fields who for more than a decade have formed the teaching staff responsible for the successful GEC-ESTRO/EAU Prostate Brachytherapy Teaching Course. This book will be invaluable in informing residents and others of the scientific background and potential of modern prostate brachytherapy. It will also prove a useful source of up-to-date information for those who specialize in prostate brachytherapy or intend to start an interstitial brachytherapy service.

  19. Study and development of methodology for radioactive iodine fixation in polymeric substrate for manufacturing sources used in brachytherapy

    International Nuclear Information System (INIS)

    Rodrigues, Bruna T.; Souza, Carla D.; Benega, Marcos A.G. and others

    2014-01-01

    According global estimates of Globocan 2012 project of the International Agency for Research of Cancer, of the World Health Organization, there were 14,1 million new cases of cancer and a total of 8,2 million deaths from cancer. Also show that in 2030, the overall load will be 21,4 million new cases and 13,2 million cancer deaths. One of the prostate cancer therapy is brachytherapy, used in early and middle stages of the disease. It is made with the introduction of seeds with radioactive material within the tumor or in nearby regions, affecting the minimum surrounding tissues. The aim of this work is the study and developing the deposition of radioactive iodine on the polymeric substrate method, and an analysis relating the efficiency of the method to implementation in the laboratory of brachytherapy from IPEN. Iodine-125 is adsorbed on an epoxy resin solution. The objective of this study is to offer a new proposal for seeds. The results will give the data for the radiation protection and the procedures for radioactive waste management

  20. Brachytherapy optimal planning with application to intravascular radiation therapy

    DEFF Research Database (Denmark)

    Sadegh, Payman; Mourtada, Firas A.; Taylor, Russell H.

    1999-01-01

    determination of an optimal dwell-time sequence for a train of seeds that deliver ratiation while stepping through the vessel lesion. The results illustrate the advantage of this strategy over the common approach of delivering radiation by positioning a single train of seeds along the whole lesion....

  1. Dosimetric characterization of low dose rate Iridium 192 wires used in interstitial brachytherapy, produced by Brachytherapy Sources Laboratory the CTRS/IPEN/CNEN-SP, Brazil

    International Nuclear Information System (INIS)

    Silva, Marco Antonio da

    2003-01-01

    In this work they were some dosimetric parameters established by the dosimetry protocol AAPM TG-43 for the thread of 192 Ir with the purpose of complementing the dosimetric specifications of an original source produced at the country. For so much quantities such as the constant of dose rate, A , function of radial dose, g(r), and anisotropy function, F(r,θ), they were experimentally determined and the geometry function, G(r,θ), it was calculated. Measurements with TLD of LiF, with dimensions of 1 mm X 1 mm X 1 mm, was made in a phantom made of 5 plates of solid water RW3 material with dimensions of 300 mm X 300 mm X 10 mm, where it was obtained values of dose rate for some radial distances of the source, between 10 and 100 mm, to for an angle of 90 deg, for g(r), and also for other angles between 0 deg and 180 deg for F(r,θ). Threads of 192 Ir were studied in the lengths of 10 mm, 20 mm, 30 mm, 50 mm and 100 mm. The stored energy on the thermoluminescent dosimeters was integrated by means of a TLD reader Harshaw 2000 meantime into a cycle of thermal treatment to which the thermoluminescent dosimeters was submitted being, 400 C in an interval of time of 1 hour proceeded immediately for more 2 hours to 105 C, after this treatment the thermoluminescent dosimeters was irradiated; even so, before the reading the detectors was still warm to 105 deg C for 10 minutes. The constant of dose rate for the threads of 192 Ir of 10 mm, 20 mm, 30 mm, 50 mm and 100 mm are (1,076 =- 3,7%); (0,931 =- 3,7%); (0,714 =- 3,7%); (0,589 =-3,7%) and (0,271 =- 3,7%) cGyh -1 U -1 , respectively (1U = unit of kerma intensity in the air = 1mGy m 2 h -1 = 1cGy cm 2 h -1 ). The results obtained for g(r) and F(r,θ) have uncertainties of (=- 4,5%) and they are compared with values obtained by Monte Carlo simulation and also for other values presented in the literature. (author)

  2. Technical Note: Monte Carlo calculations of the AAPM TG-43 brachytherapy dosimetry parameters for a new titanium-encapsulated Yb-169 source.

    Science.gov (United States)

    Reynoso, Francisco J; Munro Iii, John J; Cho, Sang Hyun

    2017-07-01

    Due to a number of distinct advantages resulting from the relatively low energy gamma ray spectrum of Yb-169, various designs of Yb-169 sources have been developed over the years for brachytherapy applications. Lately, Yb-169 has also been suggested as an effective and practical radioisotope option for a novel radiation treatment approach often known as gold nanoparticle-aided radiation therapy (GNRT). In a recently published study, the current investigators used the Monte Carlo N-Particle Version 5 (MCNP5) code to design a novel titanium-encapsulated Yb-169 source optimized for GNRT applications. In this study, the original MC source model was modified to accurately match the specifications of the manufactured Yb-169 source. The modified MC model was then used to obtain a complete set of the AAPM TG-43 parameters for the new titanium-encapsulated Yb-169 source. The MC-calculated dose rate constant for this titanium-encapsulated Yb-169 source was 1.19 ± 0.03 cGy·h-1·U-1, indicating no significant change from the values reported for stainless steel-encapsulated Yb-169 sources. The source anisotropy and radial dose function for the new source were also found similar to those reported for the stainless steel-encapsulated Yb-169 sources. The current results suggest that the use of titanium, instead of stainless steel, to encapsulate the Yb-169 core would not lead to any major change in the dosimetric characteristics of the Yb-169 source. The results also show that the titanium encapsulation of the Yb-169 source could be accomplished while meeting the design goals as described in the current investigators' published MC optimization study for GNRT applications. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  3. SU-E-T-758: To Determine the Source Dwell Positions of HDR Brachytherapy Using 2D 729 Ion Chamber Array

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Syam [Malabar Cancer Centre, Kannur, Kerala (India); Sitha [University of Calicut, Calicut, Kerala (India)

    2015-06-15

    Purpose: Determination of source dwell positions of HDR brachytherapy using 2D 729 ion chamber array Methods: Nucletron microselectron HDR and PTW 2D array were used for the study. Different dwell positions were assigned in the HDR machine. Rigid interstitial needles and vaginal applicator were positioned on the 2D array. The 2D array was exposed for this programmed dwell positions. The positional accuracy of the source was analyzed after the irradiation of the 2D array. This was repeated for different dwell positions. Different test plans were transferred from the Oncentra planning system and irradiated with the same applicator position on the 2D array. The results were analyzed using the in house developed excel program. Results: Assigned dwell positions versus corresponding detector response were analyzed. The results show very good agreement with the film measurements. No significant variation found between the planned and measured dwell positions. Average dose response with 2D array between the planned and nearby dwell positions was found to be 0.0804 Gy for vaginal cylinder applicator and 0.1234 Gy for interstitial rigid needles. Standard deviation between the doses for all the measured dwell positions for interstitial rigid needle for 1 cm spaced positions were found to be 0.33 and 0.37 for 2cm spaced dwell positions. For intracavitory vaginal applicator this was found to be 0.21 for 1 cm spaced dwell positions and 0.06 for 2cm spaced dwell positions. Intracavitory test plans reproduced on the 2D array with the same applicator positions shows the ideal dose distribution with the TPS planned. Conclusion: 2D array is a good tool for determining the dwell position of HDR brachytherapy. With the in-house developed program in excel it is easy and accurate. The traditional way with film analysis can be replaced by this method, as the films will be more costly.

  4. SU-E-T-758: To Determine the Source Dwell Positions of HDR Brachytherapy Using 2D 729 Ion Chamber Array

    International Nuclear Information System (INIS)

    Kumar, Syam; Sitha

    2015-01-01

    Purpose: Determination of source dwell positions of HDR brachytherapy using 2D 729 ion chamber array Methods: Nucletron microselectron HDR and PTW 2D array were used for the study. Different dwell positions were assigned in the HDR machine. Rigid interstitial needles and vaginal applicator were positioned on the 2D array. The 2D array was exposed for this programmed dwell positions. The positional accuracy of the source was analyzed after the irradiation of the 2D array. This was repeated for different dwell positions. Different test plans were transferred from the Oncentra planning system and irradiated with the same applicator position on the 2D array. The results were analyzed using the in house developed excel program. Results: Assigned dwell positions versus corresponding detector response were analyzed. The results show very good agreement with the film measurements. No significant variation found between the planned and measured dwell positions. Average dose response with 2D array between the planned and nearby dwell positions was found to be 0.0804 Gy for vaginal cylinder applicator and 0.1234 Gy for interstitial rigid needles. Standard deviation between the doses for all the measured dwell positions for interstitial rigid needle for 1 cm spaced positions were found to be 0.33 and 0.37 for 2cm spaced dwell positions. For intracavitory vaginal applicator this was found to be 0.21 for 1 cm spaced dwell positions and 0.06 for 2cm spaced dwell positions. Intracavitory test plans reproduced on the 2D array with the same applicator positions shows the ideal dose distribution with the TPS planned. Conclusion: 2D array is a good tool for determining the dwell position of HDR brachytherapy. With the in-house developed program in excel it is easy and accurate. The traditional way with film analysis can be replaced by this method, as the films will be more costly

  5. SU-F-BRA-09: New Efficient Method for Xoft Axxent Electronic Brachytherapy Source Calibration by Pre-Characterizing Surface Applicators

    Energy Technology Data Exchange (ETDEWEB)

    Pai, S [iCAD Inc., Los Gatos, CA (United States)

    2015-06-15

    Purpose: The objective is to improve the efficiency and efficacy of Xoft™ Axxent™ electronic brachytherapy (EBT) calibration of the source & surface applicator using AAPM TG-61 formalism. Methods: Current method of Xoft EBT source calibration involves determination of absolute dose rate of the source in each of the four conical surface applicators using in-air chamber measurements & TG61 formalism. We propose a simplified TG-61 calibration methodology involving initial characterization of surface cone applicators. This is accomplished by calibrating dose rates for all 4 surface applicator sets (for 10 sources) which establishes the “applicator output ratios” with respect to the selected reference applicator (20 mm applicator). After the initial time, Xoft™ Axxent™ source TG61 Calibration is carried out only in the reference applicator. Using the established applicator output ratios, dose rates for other applicators will be calculated. Results: 200 sources & 8 surface applicator sets were calibrated cumulatively using a Standard Imaging A20 ion-chamber in accordance with manufacturer-recommended protocols. Dose rates of 10, 20, 35 & 50mm applicators were normalized to the reference (20mm) applicator. The data in Figure 1 indicates that the normalized dose rate variation for each applicator for all 200 sources is better than ±3%. The average output ratios are 1.11, 1.02 and 0.49 for the 10 mm,35 mm and 50 mm applicators, respectively, which are in good agreement with the manufacturer’s published output ratios of 1.13, 1.02 and 0.49. Conclusion: Our measurements successfully demonstrate the accuracy of a new calibration method using a single surface applicator for Xoft EBT sources and deriving the dose rates of other applicators. The accuracy of the calibration is improved as this method minimizes the source position variation inside the applicator during individual source calibrations. The new method significantly reduces the calibration time to less

  6. SU-E-T-102: Determination of Dose Distributions and Water-Equivalence of MAGIC-F Polymer Gel for 60Co and 192Ir Brachytherapy Sources

    Energy Technology Data Exchange (ETDEWEB)

    Quevedo, A; Nicolucci, P [University of Sao Paulo, Ribeirao Preto, SP (Brazil)

    2014-06-01

    Purpose: Analyse the water-equivalence of MAGIC-f polymer gel for {sup 60}Co and {sup 192}Ir clinical brachytherapy sources, through dose distributions simulated with PENELOPE Monte Carlo code. Methods: The real geometry of {sup 60} (BEBIG, modelo Co0.A86) and {sup 192}192Ir (Varian, model GammaMed Plus) clinical brachytherapy sources were modelled on PENELOPE Monte Carlo simulation code. The most probable emission lines of photons were used for both sources: 17 emission lines for {sup 192}Ir and 12 lines for {sup 60}. The dose distributions were obtained in a cubic water or gel homogeneous phantom (30 × 30 × 30 cm{sup 3}), with the source positioned in the middle of the phantom. In all cases the number of simulation showers remained constant at 10{sup 9} particles. A specific material for gel was constructed in PENELOPE using weight fraction components of MAGIC-f: wH = 0,1062, wC = 0,0751, wN = 0,0139, wO = 0,8021, wS = 2,58×10{sup −6} e wCu = 5,08 × 10{sup −6}. The voxel size in the dose distributions was 0.6 mm. Dose distribution maps on the longitudinal and radial direction through the centre of the source were used to analyse the water-equivalence of MAGIC-f. Results: For the {sup 60} source, the maximum diferences in relative doses obtained in the gel and water were 0,65% and 1,90%, for radial and longitudinal direction, respectively. For {sup 192}Ir, the maximum difereces in relative doses were 0,30% and 1,05%, for radial and longitudinal direction, respectively. The materials equivalence can also be verified through the effective atomic number and density of each material: Zef-MAGIC-f = 7,07 e .MAGIC-f = 1,060 g/cm{sup 3} and Zef-water = 7,22. Conclusion: The results showed that MAGIC-f is water equivalent, consequently being suitable to simulate soft tissue, for Cobalt and Iridium energies. Hence, gel can be used as a dosimeter in clinical applications. Further investigation to its use in a clinical protocol is needed.

  7. Disseminated intravascular coagulation in sepsis

    NARCIS (Netherlands)

    Zeerleder, Sacha; Hack, C. Erik; Wuillemin, Walter A.

    2005-01-01

    Disseminated intravascular coagulation is a frequent complication of sepsis. Coagulation activation, inhibition of fibrinolysis, and consumption of coagulation inhibitors lead to a procoagulant state resulting in inadequate fibrin removal and fibrin deposition in the microvasculature. As a

  8. Influence of radioactive sources discretization in the Monte Carlo computational simulations of brachytherapy procedures: a case study on the procedures for treatment of prostate cancer; Influencia da discretizacao das fontes radioativas nas simulacoes computacionais Monte Carlo de procedimentos de braquiterapia: um estudo de caso sobre os procedimentos para tratamento do cancer de prostata

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Antonio Konrado de Santana; Vieira, Jose Wilson [Instituto Federal de Educacao, Ciencia e Tecnologia (IFPE), Recife, PE (Brazil); Costa, Kleber Souza Silva [Faculdade Integrada de Pernambuco (FACIPE), Recife, PE (Brazil); Lima, Fernando Roberto de Andrade, E-mail: falima@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2011-07-01

    Radiotherapy computational simulation procedures using Monte Carlo (MC) methods have shown to be increasingly important to the improvement of cancer fighting strategies. One of the biases in this practice is the discretization of the radioactive source in brachytherapy simulations, which often do not match with a real situation. This study had the aim to identify and to measure the influence of radioactive sources discretization in brachytherapy MC simulations when compared to those that do not present discretization, using prostate brachytherapy with Iodine-125 radionuclide as model. Simulations were carried out with 108 events with both types of sources to compare them using EGSnrc code associated to MASH phantom in orthostatic and supine positions with some anatomic adaptations. Significant alterations were found, especially regarding bladder, rectum and the prostate itself. It can be concluded that there is a need to discretized sources in brachytherapy simulations to ensure its representativeness. (author)

  9. Dosimetric comparison between the microSelectron HDR 192Ir v2 source and the BEBIG 60Co source for HDR brachytherapy using the EGSnrc Monte Carlo transport code

    International Nuclear Information System (INIS)

    Anwarul Islam, M.; Akramuzzaman, M.M.; Zakaria, G.A.

    2012-01-01

    Manufacturing of miniaturized high activity 192 Ir sources have been made a market preference in modern brachytherapy. The smaller dimensions of the sources are flexible for smaller diameter of the applicators and it is also suitable for interstitial implants. Presently, miniaturized 60 Co HDR sources have been made available with identical dimensions to those of 192 Ir sources. 60 Co sources have an advantage of longer half life while comparing with 192 Ir source. High dose rate brachytherapy sources with longer half life are logically pragmatic solution for developing country in economic point of view. This study is aimed to compare the TG-43U1 dosimetric parameters for new BEBIG 60 Co HDR and new microSelectron 192 Ir HDR sources. Dosimetric parameters are calculated using EGSnrc-based Monte Carlo simulation code accordance with the AAPM TG-43 formalism for microSelectron HDR 192 Ir v2 and new BEBIG 60 Co HDR sources. Air-kerma strength per unit source activity, calculated in dry air are 9.698x10 -8 ± 0.55% U Bq -1 and 3.039x10 -7 ± 0.41% U Bq -1 for the above mentioned two sources, respectively. The calculated dose rate constants per unit air-kerma strength in water medium are 1.116±0.12% cGy h -1 U -1 and 1.097±0.12% cGy h -1 U -1 , respectively, for the two sources. The values of radial dose function for distances up to 1 cm and more than 22 cm for BEBIG 60 Co HDR source are higher than that of other source. The anisotropic values are sharply increased to the longitudinal sides of the BEBIG 60 Co source and the rise is comparatively sharper than that of the other source. Tissue dependence of the absorbed dose has been investigated with vacuum phantom for breast, compact bone, blood, lung, thyroid, soft tissue, testis, and muscle. No significant variation is noted at 5 cm of radial distance in this regard while comparing the two sources except for lung tissues. The true dose rates are calculated with considering photon as well as electron transport using

  10. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters; Proposta de um sistema postal para a calibracao de fontes de {sup 192} Ir, utilizadas em braquiterapia de alta taxa de dose, com dosimetros termoluminescentes de LiF: Mn: Ti

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V. [Instituto de Radioprotecao e Dosimetria. CNEN Caixa Postal 37750, 22780-160, Rio de Janeiro (Brazil)

    1998-12-31

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  11. Radiation safety and gynaecological brachytherapy

    International Nuclear Information System (INIS)

    Crawford, L.

    1985-01-01

    In 1983, the Radiation Control Section of the South Australian Health Commission conducted an investigation into radiation safety practices in gynaecological brachytherapy. Part of the investigation included a study of the transportation of radioactive sources between hospitals. Several deficiences in radiation safety were found in the way these sources were being transported. New transport regulations came into force in South Australia in July 1984 and since then there have been many changes in the transportation procedure

  12. Synthesis and characterization of hydroxyapatite porous matrixes for application as radiation sources in brachytherapy; Sintese e caracterizacao de matrizes porosas de hidroxiapatita para aplicacao como fontes radioativas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, Kassio Andre; Lameiras, Fernando Soares; Silva, Viviane Viana [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)]. E-mail: kassiolacerda@yahoo.com.br

    2006-04-15

    Porous ceramic materials based on calcium phosphate compounds (CPC) have been studied aiming at different biomedical applications such as implants, drug delivery systems and radioactive sources for brachytherapy. Two kinds of hydroxyapatite (HAp) powders and their ceramic bodies were characterized by a combination of different techniques (X-rays diffraction and fluorescence, infrared spectrophotometry, BET method, thermal analysis, and scanning electron microscopy) to evaluate their physico-chemical and microstructural characteristics in terms of chemical composition, segregated phases, microstructure, porosity, and chemical and thermal stability. The results revealed that these systems presented potential for use as porous biodegradable radioactive sources able to be loaded with a wide range of radionuclides for cancer treatment by the brachytherapy technique. (author)

  13. Verification and source-position error analysis of film reconstruction techniques used in the brachytherapy planning systems.

    Science.gov (United States)

    Chang, Liyun; Ho, Sheng-Yow; Chui, Chen-Shou; Du, Yi-Chun; Chen, Tainsong

    2009-09-01

    A method was presented that employs standard linac QA tools to verify the accuracy of film reconstruction algorithms used in the brachytherapy planning system. Verification of reconstruction techniques is important as suggested in the ESTRO booklet 8: "The institution should verify the full process of any reconstruction technique employed clinically." Error modeling was also performed to analyze seed-position errors. The "isocentric beam checker" device was used in this work. It has a two-dimensional array of steel balls embedded on its surface. The checker was placed on the simulator couch with its center ball coincident with the simulator isocenter, and one axis of its cross marks parallel to the axis of gantry rotation. The gantry of the simulator was rotated to make the checker behave like a three-dimensional array of balls. Three algorithms used in the ABACUS treatment planning system: orthogonal film, 2-films-with-variable-angle, and 3-films-with-variable-angle were tested. After exposing and digitizing the films, the position of each steel ball on the checker was reconstructed and compared to its true position, which can be accurately calculated. The results showed that the error is dependent on the object-isocenter distance, but not the magnification of the object. The averaged errors were less than 1 mm within the tolerance level defined by Roué et al. ["The EQUAL-ESTRO audit on geometric reconstruction techniques in brachytherapy," Radiother. Oncol. 78, 78-83 (2006)]. However, according to the error modeling, the theoretical error would be greater than 2 mm if the objects were located more than 20 cm away from the isocenter with a 0.5 degrees reading error of the gantry and collimator angles. Thus, in addition to carefully performing the QA of the gantry and collimator angle indicators, it is suggested that the patient, together with the applicators or seeds inside, should be placed close to the isocenter as much as possible. This method could be used to

  14. A generic high-dose rate {sup 192}Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

    Energy Technology Data Exchange (ETDEWEB)

    Ballester, Facundo, E-mail: Facundo.Ballester@uv.es [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Carlsson Tedgren, Åsa [Department of Medical and Health Sciences (IMH), Radiation Physics, Faculty of Health Sciences, Linköping University, Linköping SE-581 85, Sweden and Department of Medical Physics, Karolinska University Hospital, Stockholm SE-171 76 (Sweden); Granero, Domingo [Department of Radiation Physics, ERESA, Hospital General Universitario, Valencia E-46014 (Spain); Haworth, Annette [Department of Physical Sciences, Peter MacCallum Cancer Centre and Royal Melbourne Institute of Technology, Melbourne, Victoria 3000 (Australia); Mourtada, Firas [Department of Radiation Oncology, Helen F. Graham Cancer Center, Christiana Care Health System, Newark, Delaware 19713 (United States); Fonseca, Gabriel Paiva [Instituto de Pesquisas Energéticas e Nucleares – IPEN-CNEN/SP, São Paulo 05508-000, Brazil and Department of Radiation Oncology (MAASTRO), GROW, School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Zourari, Kyveli; Papagiannis, Panagiotis [Medical Physics Laboratory, Medical School, University of Athens, 75 MikrasAsias, Athens 115 27 (Greece); Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Siebert, Frank-André [Clinic of Radiotherapy, University Hospital of Schleswig-Holstein, Campus Kiel, Kiel 24105 (Germany); Sloboda, Ron S. [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada); and others

    2015-06-15

    Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) {sup 192}Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR {sup 192}Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic {sup 192}Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra{sup ®} Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS{sup TM}]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201){sup 3} voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR {sup 192}Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by

  15. Comprehensive brachytherapy physical and clinical aspects

    CERN Document Server

    Baltas, Dimos; Meigooni, Ali S; Hoskin, Peter J

    2013-01-01

    Modern brachytherapy is one of the most important oncological treatment modalities requiring an integrated approach that utilizes new technologies, advanced clinical imaging facilities, and a thorough understanding of the radiobiological effects on different tissues, the principles of physics, dosimetry techniques and protocols, and clinical expertise. A complete overview of the field, Comprehensive Brachytherapy: Physical and Clinical Aspects is a landmark publication, presenting a detailed account of the underlying physics, design, and implementation of the techniques, along with practical guidance for practitioners. Bridging the gap between research and application, this single source brings together the technological basis, radiation dosimetry, quality assurance, and fundamentals of brachytherapy. In addition, it presents discussion of the most recent clinical practice in brachytherapy including prostate, gynecology, breast, and other clinical treatment sites. Along with exploring new clinical protocols, ...

  16. In vivo dosimetry HDR brachytherapy prostate with source CO-60: Results of measures in a point urethra; Dosimetria in vivo en braquiterapia HDR de prostate con fuente de CO-60: Resultados de medidas en un punto de uretra

    Energy Technology Data Exchange (ETDEWEB)

    Latorre, D.; Fernandez, J.; Rivero, G.; Crelgo, D.; Gonzalez, J. M.; Sanchez, P.; Villace, A.; Sanchez, E.; Arroyo, M. A.; Garcia, E.; Trabanco, E.

    2015-07-01

    In this study we present and analyze the results of the in vivo dosimetry made a point of urethra with a group of 30 patients treated with brachytherapy prostate high rate with Co-60 source. Taking into account the uncertainties, the results and integration, globally evaluate this system DIV. This DIV system, due to its ease of calibration and use, and provides a relatively simple integration way to avoid serious errors in administering treatment. (Author)

  17. SU-F-T-32: Evaluation of the Performance of a Multiple-Array-Diode Detector for Quality Assurance Tests in High-Dose-Rate Brachytherapy with Ir-192 Source

    Energy Technology Data Exchange (ETDEWEB)

    Harpool, K; De La Fuente Herman, T; Ahmad, S; Ali, I [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2016-06-15

    Purpose: To evaluate the performance of a two-dimensional (2D) array-diode- detector for geometric and dosimetric quality assurance (QA) tests of high-dose-rate (HDR) brachytherapy with an Ir-192-source. Methods: A phantom setup was designed that encapsulated a two-dimensional (2D) array-diode-detector (MapCheck2) and a catheter for the HDR brachytherapy Ir-192 source. This setup was used to perform both geometric and dosimetric quality assurance for the HDR-Ir192 source. The geometric tests included: (a) measurement of the position of the source and (b) spacing between different dwell positions. The dosimteric tests include: (a) linearity of output with time, (b) end effect and (c) relative dose verification. The 2D-dose distribution measured with MapCheck2 was used to perform the previous tests. The results of MapCheck2 were compared with the corresponding quality assurance testes performed with Gafchromic-film and well-ionization-chamber. Results: The position of the source and the spacing between different dwell-positions were reproducible within 1 mm accuracy by measuring the position of maximal dose using MapCheck2 in contrast to the film which showed a blurred image of the dwell positions due to limited film sensitivity to irradiation. The linearity of the dose with dwell times measured from MapCheck2 was superior to the linearity measured with ionization chamber due to higher signal-to-noise ratio of the diode readings. MapCheck2 provided more accurate measurement of the end effect with uncertainty < 1.5% in comparison with the ionization chamber uncertainty of 3%. Although MapCheck2 did not provide absolute calibration dosimeter for the activity of the source, it provided accurate tool for relative dose verification in HDR-brachytherapy. Conclusion: The 2D-array-diode-detector provides a practical, compact and accurate tool to perform quality assurance for HDR-brachytherapy with an Ir-192 source. The diodes in MapCheck2 have high radiation sensitivity and

  18. Direct reconstruction and associated uncertainties of 192Ir source dwell positions in ring applicators using gafchromic film in the treatment planning of HDR brachytherapy cervix patients

    Science.gov (United States)

    Awunor, O. A.; Dixon, B.; Walker, C.

    2013-05-01

    This paper details a practical method for the direct reconstruction of high dose rate 192Ir source dwell positions in ring applicators using gafchromic film in the treatment planning of brachytherapy cervix patients. It also details the uncertainties associated with such a process. Eight Nucletron interstitial ring applicators—Ø26 mm (×4), Ø30 mm (×3) and Ø34 mm (×1), and one 60 mm intrauterine tube were used in this study. RTQA2 and XRQA2 gafchromic films were irradiated at pre-programmed dwell positions with three successive 192Ir sources and used to derive the coordinates of the source dwell positions. The source was observed to deviate significantly from its expected position by up to 6.1 mm in all ring sizes. Significant inter applicator differences of up to 2.6 mm were observed between a subset of ring applicators. Also, the measured data were observed to differ significantly from commercially available source path models provided by Nucletron with differences of up to 3.7 mm across all ring applicator sizes. The total expanded uncertainty (k = 2) averaged over all measured dwell positions in the rings was observed to be 1.1 ± 0.1 mm (Ø26 mm and Ø30 mm rings) and 1.0 ± 0.3 mm (Ø34 mm ring) respectively, and when transferred to the treatment planning system, equated to maximum %dose changes of 1.9%, 13.2% and 1.5% at regions representative of the parametrium, lateral fornix and organs at risk respectively.

  19. Direct reconstruction and associated uncertainties of 192Ir source dwell positions in ring applicators using gafchromic film in the treatment planning of HDR brachytherapy cervix patients

    International Nuclear Information System (INIS)

    Awunor, O A; Dixon, B; Walker, C

    2013-01-01

    This paper details a practical method for the direct reconstruction of high dose rate 192 Ir source dwell positions in ring applicators using gafchromic film in the treatment planning of brachytherapy cervix patients. It also details the uncertainties associated with such a process. Eight Nucletron interstitial ring applicators—Ø26 mm (×4), Ø30 mm (×3) and Ø34 mm (×1), and one 60 mm intrauterine tube were used in this study. RTQA2 and XRQA2 gafchromic films were irradiated at pre-programmed dwell positions with three successive 192 Ir sources and used to derive the coordinates of the source dwell positions. The source was observed to deviate significantly from its expected position by up to 6.1 mm in all ring sizes. Significant inter applicator differences of up to 2.6 mm were observed between a subset of ring applicators. Also, the measured data were observed to differ significantly from commercially available source path models provided by Nucletron with differences of up to 3.7 mm across all ring applicator sizes. The total expanded uncertainty (k = 2) averaged over all measured dwell positions in the rings was observed to be 1.1 ± 0.1 mm (Ø26 mm and Ø30 mm rings) and 1.0 ± 0.3 mm (Ø34 mm ring) respectively, and when transferred to the treatment planning system, equated to maximum %dose changes of 1.9%, 13.2% and 1.5% at regions representative of the parametrium, lateral fornix and organs at risk respectively. (paper)

  20. Characteristics of miniature electronic brachytherapy x-ray sources based on TG-43U1 formalism using Monte Carlo simulation techniques

    International Nuclear Information System (INIS)

    Safigholi, Habib; Faghihi, Reza; Jashni, Somaye Karimi; Meigooni, Ali S.

    2012-01-01

    Purpose: The goal of this study is to determine a method for Monte Carlo (MC) characterization of the miniature electronic brachytherapy x-ray sources (MEBXS) and to set dosimetric parameters according to TG-43U1 formalism. TG-43U1 parameters were used to get optimal designs of MEBXS. Parameters that affect the dose distribution such as anode shapes, target thickness, target angles, and electron beam source characteristics were evaluated. Optimized MEBXS designs were obtained and used to determine radial dose functions and 2D anisotropy functions in the electron energy range of 25-80 keV. Methods: Tungsten anode material was considered in two different geometries, hemispherical and conical-hemisphere. These configurations were analyzed by the 4C MC code with several different optimization techniques. The first optimization compared target thickness layers versus electron energy. These optimized thicknesses were compared with published results by Ihsan et al.[Nucl. Instrum. Methods Phys. Res. B 264, 371-377 (2007)]. The second optimization evaluated electron source characteristics by changing the cathode shapes and electron energies. Electron sources studied included; (1) point sources, (2) uniform cylinders, and (3) nonuniform cylindrical shell geometries. The third optimization was used to assess the apex angle of the conical-hemisphere target. The goal of these optimizations was to produce 2D-dose anisotropy functions closer to unity. An overall optimized MEBXS was developed from this analysis. The results obtained from this model were compared to known characteristics of HDR 125 I, LDR 103 Pd, and Xoft Axxent electronic brachytherapy source (XAEBS) [Med. Phys. 33, 4020-4032 (2006)]. Results: The optimized anode thicknesses as a function of electron energy is fitted by the linear equation Y (μm) = 0.0459X (keV)-0.7342. The optimized electron source geometry is obtained for a disk-shaped parallel beam (uniform cylinder) with 0.9 mm radius. The TG-43 distribution

  1. Applying gold nanoparticles as tumor-vascular disrupting agents during brachytherapy: estimation of endothelial dose enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Ngwa, Wilfred; Makrigiorgos, G Mike; Berbeco, Ross I, E-mail: mmakrigiorgos@lroc.harvard.ed [Department of Radiation Oncology, Division of Medical Physics and Biophysics, Brigham and Women' s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA 02115 (United States)

    2010-11-07

    Tumor vascular disrupting agents (VDAs) represent a promising approach to the treatment of cancer, in view of the tumor vasculature's pivotal role in tumor survival, growth and metastasis. VDAs targeting the tumor's dysmorphic endothelial cells can cause selective and rapid occlusion of the tumor vasculature, leading to tumor cell death from ischemia and extensive hemorrhagic necrosis. In this study, the potential for applying gold nanoparticles (AuNPs) as VDAs, during brachytherapy, is examined. Analytic calculations based on the electron energy loss formula of Cole were carried out to estimate the endothelial dose enhancement caused by radiation-induced photo/Auger electrons originating from AuNPs targeting the tumor endothelium. The endothelial dose enhancement factor (EDEF), representing the ratio of the dose to the endothelium with and without gold nanoparticles was calculated for different AuNP local concentrations, and endothelial cell thicknesses. Four brachytherapy sources were investigated, I-125, Pd-103, Yb-169, as well as 50 kVp x-rays. The results reveal that, even at relatively low intra-vascular AuNP concentrations, ablative dose enhancement to tumor endothelial cells due to photo/Auger electrons from the AuNPs can be achieved. Pd-103 registered the highest EDEF values of 7.4-271.5 for local AuNP concentrations ranging from 7 to 350 mg g{sup -1}, respectively. Over the same concentration range, I-125, 50 kVp and Yb-169 yielded values of 6.4-219.9, 6.3-214.5 and 4.0-99.7, respectively. Calculations of the EDEF as a function of endothelial cell thickness showed that lower energy sources like Pd-103 reach the maximum EDEF at smaller thicknesses. The results also reveal that the highest contribution to the EDEF comes from Auger electrons, apparently due to their shorter range. Overall, the data suggest that ablative dose enhancement to tumor endothelial cells can be achieved by applying tumor vasculature-targeted AuNPs as adjuvants to

  2. Characterization of TLD-100 in powders for dosimetric quality control of 192 Ir sources used in brachytherapy of high dose rate

    International Nuclear Information System (INIS)

    Loaiza C, S.P.

    2007-01-01

    The Secondary Standard Dosimetric at the National Institute of Nuclear Research (ININ) calibrated a lot of powdered TLD-100 (LiF:Mg,Ti) in terms of absorbed dose to water D w for the energy of: 60 Co, 137C s, X rays of 250 and 50 kVp. Later on, it is carried out an interpolation of the calibration for the energy of the 192 Ir. This calibration is part of a dosimetric quality control program, to solve the problems of traceability for the measurements carried out by the users of 192 Ir sources employed in the treatments of High Dose Rate Brachytherapy (HDR) at the Mexican Republic. The calibrations of the radiation beams are made with the following protocols: IAEA TRS-398 for the 60 Co for D w , using a secondary standard ionization chamber PTW N30013 calibrated in D w by the National Research Council (NRC, Canada). AAPM TG-43 for D w in terms of the strength kerma Sk, calibrating this last one quantity for the 137 Cs radioactive source, with a well chamber HDR 1000 PLUS traceable to the University of Wisconsin (US). AAPM TG-61 for X ray of 250 and 50 kVp for D w start to Ka using field standard a Farmer chamber PTW 30001 traceable to K for the Central Laboratory of Electric Industries (CLEI, France). The calibration curves (CC) they built for the response of the powder TLD: R TLD vs D w : For the energy of 60 Co, 137 Cs, X rays of 250 and 50 kVp. Fitting them with the least square method weighed by means of a polynomial of second grade that corrects the supra linearity of the response. iii. Each one of the curves was validated with a test by lack of fitting and for the Anderson Darling normality test, using the software MINITAB in both cases. iv. The sensibility factor (F s ) for each energy corresponds to the slope of the CC, v. The F s for the two 192 Ir sources used are interpolated: one for a Micro Selectron source and the other one a Vari Source source. Finally, a couple of capsules were sent to two hospitals that have the HDR Brachytherapy with sources of 192

  3. Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: Source dosimetry, treatment planning, equipment performance and in vivo verification techniques

    OpenAIRE

    Palmer, A; Bradley, D; Nisbet, A

    2012-01-01

    This study provides a review of recent publications on the physics-aspects of dosimetric accuracy in high dose rate (HDR) brachytherapy. The discussion of accuracy is primarily concerned with uncertainties, but methods to improve dose conformation to the prescribed intended dose distribution are also noted. The main aim of the paper is to review current practical techniques and methods employed for HDR brachytherapy dosimetry. This includes work on the determination of dose rate fields around...

  4. Prototypes of phosphorus-32 sealed sources for use in Brachytherapy; Prototipo de fuente radiactiva de fosforo para uso medico en braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Anaya Garro, Olgger; Vela Mora, Mariano; Revilla Silva, Angel Revilla [Instituto Peruano de Energia Nuclear (IPEN), Lima (Peru)]. E-mail: oanaya@ipen.gob.pe; mvela@ipen.gob.pe; arevilla@ipen.gob.pe

    2005-07-01

    It has developed prototypes of phosphorus-32 sealed sources for use in Brachytherapy. This one was made in two stages, at the first one, we designed and constructed the container (capsule), the filling system and the sealed system; at the second one, we made the irradiation of the capsules containing the 'target'. The prototypes was made of aluminum in cylindrical geometry. During the irradiation test was made using two different dimensions: one of 1 mm outer diameter and 1 cm length and another one of 0.8 mm outer diameter and 5 mm length. They were radiated in the core of the RP-10 research reactor, at 7.93 x10{sup 13} n/cm{sup 2}.s thermal neutron flux during 27 operation cycles. Activities of 144.53 MBq (3.91 mCi) and 107.67 MBq (2.91 mCi) was obtained for each case. This activities are adequate to restenosis and for some tumors treatment. We can observed that the capsules irradiated passed visual inspection in its physical integrity (leakage and geometry). It has been demonstrated, that the beta radiation for his minor power of penetration and its high interaction, causes major local damage to the malignant tissue, minimizing the damage of the healthy surrounding tissues. It has been advisable to use for the treatment of illnesses of the circulatory system and some tumors. At the present, the source of strontium-90 are the most beta ray source used, but of this one are obtained as fission product of uranium target, where valuable radioactive waste is generated, whereas if we were using phosphorus-32 that we propose, radioactive waste would not be generated since it would take place directly as sealed source, for reaction (n, {beta}). (author)

  5. Physical aspects of radioisotope brachytherapy

    International Nuclear Information System (INIS)

    1967-01-01

    The present report represents an attempt to provide, within a necessarily limited compass, an authoritative guide to all important physical aspects of the use of sealed gamma sources in radiotherapy. Within the report, reference is made wherever necessary to the more extensive but scattered literature on this subject. While this report attempts to cover all the physical aspects of radioisotope 'brachytherapy' it does not, of course, deal exhaustively with any one part of the subject. 384 refs, 3 figs, 6 tabs

  6. Intravascular blood coagulation after irradiation

    International Nuclear Information System (INIS)

    Sushkevich, G.N.

    1981-01-01

    The problems of activation of intravascular blood coagulation (JVBC) at different stages after irradiation, are considered. JVBC peculiarities (disseminated intravascular syndrome (DIV) or thrombo hemorrhagic syndrome) are investigated. Literature on alterations which take place in the organism under effect of ionizing irradiation is analyzed. This analysis proves the characteristic features of thrombinogenesis activation and development of DIV syndrome not only in the early post-radiation period, but in the middle of radiation disease, as well. It is also shown that ionizing radiation activizes the hemocoagulation process and causes IVBC in the case of both local and general irradiation [ru

  7. Comparison of organ doses for patients undergoing balloon brachytherapy of the breast with HDR {sup 192}Ir or electronic sources using Monte Carlo simulations in a heterogeneous human phantom

    Energy Technology Data Exchange (ETDEWEB)

    Mille, Matthew M.; Xu, X. George; Rivard, Mark J. [Nuclear Engineering and Engineering Physics Program, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States); Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States)

    2010-02-15

    Purpose: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers. The radiation can be delivered using a conventional high-dose rate (HDR) {sup 192}Ir gamma-emitting source or a novel electronic brachytherapy (eBx) source which uses lower energy x rays that do not penetrate as far within the patient. A previous study [A. Dickler, M. C. Kirk, N. Seif, K. Griem, K. Dowlatshahi, D. Francescatti, and R. A. Abrams, ''A dosimetric comparison of MammoSite high-dose-rate brachytherapy and Xoft Axxent electronic brachytherapy,'' Brachytherapy 6, 164-168 (2007)] showed that the target dose is similar for HDR {sup 192}Ir and eBx. This study compares these sources based on the dose received by healthy organs and tissues away from the treatment site. Methods: A virtual patient with left breast cancer was represented by a whole-body, tissue-heterogeneous female voxel phantom. Monte Carlo methods were used to calculate the dose to healthy organs in a virtual patient undergoing balloon brachytherapy of the left breast with HDR {sup 192}Ir or eBx sources. The dose-volume histograms for a few organs which received large doses were also calculated. Additional simulations were performed with all tissues in the phantom defined as water to study the effect of tissue inhomogeneities. Results: For both HDR {sup 192}Ir and eBx, the largest mean organ doses were received by the ribs, thymus gland, left lung, heart, and sternum which were close to the brachytherapy source in the left breast. eBx yielded mean healthy organ doses that were more than a factor of {approx}1.4 smaller than for HDR {sup 192}Ir for all organs considered, except for the three closest ribs. Excluding these ribs, the average and median dose-reduction factors were {approx}28 and {approx}11, respectively. The volume distribution of doses in nearby soft tissue organs that were outside the PTV were also

  8. Prostate cancer brachytherapy

    International Nuclear Information System (INIS)

    Abreu, Carlos Eduardo Vita; Silva, Joao L. F.; Srougi, Miguel; Nesrallah, Adriano

    1999-01-01

    The transperineal brachytherapy with 125 I/Pd 103 seed implantation guided by transurethral ultrasound must be presented as therapeutical option of low urinary morbidity in patients with localized prostate cancer. The combined clinical staging - including Gleason and initial PSA - must be encouraged, for definition of a group of low risk and indication of exclusive brachytherapy. Random prospective studies are necessary in order to define the best role of brachytherapy, surgery and external beam radiation therapy

  9. SU-G-201-06: Directional Low-Dose Rate Brachytherapy: Determination of the TG-43 Dose-Rate Constant Analog for a New Pd-103 Source

    Energy Technology Data Exchange (ETDEWEB)

    Aima, M; Culberson, W; Hammer, C; Micka, J; DeWerd, L [Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI (United States)

    2016-06-15

    Purpose: The aim of this work is to determine the TG-43 dose-rate constant analog for a new directional low-dose rate brachytherapy source based on experimental methods and comparison to Monte Carlo simulations. The CivaSheet™ is a new commercially available planar source array comprised of a variable number of discrete directional source elements called “CivaDots”. Given the directional nature and non-conventional design of the source, modifications to the AAPM TG-43 protocol for dosimetry are required. As a result, various parameters of the TG-43 dosimetric formalism have to be adapted to accommodate this source. This work focuses on the dose-rate constant analog determination for a CivaDot. Methods: Dose to water measurements of the CivaDot were performed in a polymethyl methacrylate phantom (20×20×12 cm{sup 3}) using thermoluminescent dosimeters (TLDs) and Gafchromic EBT3 film. The source was placed in the center of the phantom, and nine TLD micro-cubes were irradiated along its central axis at a distance of 1 cm. For the film measurements, the TLDs were substituted by a (3×3) cm{sup 2} EBT3 film. Primary air-kerma strength measurements of the source were performed using a variable-aperture free-air chamber. Finally, the source was modeled using the Monte Carlo N-Particle Transport Code 6. Results: Dose-rate constant analog observed for a total of eight CivaDots using TLDs and five CivaDots using EBT3 film was within ±7.0% and ±2.9% of the Monte Carlo predicted value respectively. The average difference observed was −4.8% and −0.1% with a standard deviation of 1.7% and 2.1% for the TLD and the film measurements respectively, which are both within the comparison uncertainty. Conclusion: A preliminary investigation to determine the doserate constant analog for a CivaDot was conducted successfully with good agreement between experimental and Monte Carlo based methods. This work will aid in the eventual realization of a clinically-viable dosimetric

  10. Intravascular Stenting in Microvascular Anastomoses

    DEFF Research Database (Denmark)

    Assersen, Kristine; Sørensen, Jens

    2015-01-01

    Background The effect of intravascular stenting (IVaS) on microvascular anastomoses has given adverse results. For experienced microsurgeons the benefit of IVaS is doubtful. We have investigated the potential benefit of the IVaS technique for two groups of inexperienced microsurgeons with differe...

  11. Intravascular bronchio-alveolar tumor

    International Nuclear Information System (INIS)

    Mata, J.M.; Caceres, J.; Prat, J.; Lopez, J.I.; Velilla, O.

    1991-01-01

    In 1975 Dail and Liebow described the clinical and pathological characteristics of a pulmonary tumor which they dominated intravascular bronchio-alveolar tumor (IVBAT). Our aim is to acquaint radiologists with the existence of this tumor by describing the radiologic findings in 2 patients with IVBAT, 1 with hepatic involvement ant the other with pulmonary osteoarthropathy. (author). 7 refs.; 2 figs

  12. Intravascular imaging with a storage phosphor detector

    Science.gov (United States)

    Shikhaliev, Polad M.; Petrek, Peter; Matthews, Kenneth L., II; Fritz, Shannon G.; Bujenovic, L. Steven; Xu, Tong

    2010-05-01

    The aim of this study is to develop and test an intravascular positron imaging system based on a storage phosphor detector for imaging and detecting vulnerable plaques of human coronary arteries. The radiotracer F18-FDG accumulates in vulnerable plaques with inflammation of the overlying cap. The vulnerable plaques can, therefore, be imaged by recording positrons emitted from F18-FDG with a detector inserted into the artery. A prototype intravascular detector was constructed based on storage phosphor. The detector uses a flexible storage phosphor tube with 55 mm length, 2 mm diameter and 0.28 mm wall thickness. The intravascular detector is guided into the vessel using x-ray fluoroscopy and the accumulated x-ray signal must be erased prior to positron imaging. For this purpose, a light diffuser, 0.9 mm in diameter and 55 mm in length, was inserted into the detector tube. The light diffuser was connected to a laser source through a 2 m long optical fiber. The diffuser redirected the 0.38 W laser light to the inner surface of the phosphor detector to erase it. A heart phantom with 300 cm3 volume and three coronary arteries with 3.2 mm diameter and with several plaques was constructed. FDG solution with 0.5 µCi cm-3 activity concentration was filled in the heart and coronary arteries. The detector was inserted in a coronary artery and the signal from the plaques and surrounding background activity was recorded for 2 min. Then the phosphor detector was extracted and read out using a storage phosphor reader. The light diffuser erased the signal resulting from fluoroscopic exposure to level below that encountered during positron imaging. Vulnerable plaques with area activities higher than 1.2 nCi mm-2 were visualized by the detector. This activity is a factor of 10-20 lower than that expected in human vulnerable plaques. The detector was able to image the internal surface of the coronary vessels with 50 mm length and 360° circumference. Spatial resolution was 0

  13. Poster - Thur Eve - 06: Comparison of an open source genetic algorithm to the commercially used IPSA for generation of seed distributions in LDR prostate brachytherapy.

    Science.gov (United States)

    McGeachy, P; Khan, R

    2012-07-01

    In early stage prostate cancer, low dose rate (LDR) prostate brachytherapy is a favorable treatment modality, where small radioactive seeds are permanently implanted throughout the prostate. Treatment centres currently rely on a commercial optimization algorithm, IPSA, to generate seed distributions for treatment plans. However, commercial software does not allow the user access to the source code, thus reducing the flexibility for treatment planning and impeding any implementation of new and, perhaps, improved clinical techniques. An open source genetic algorithm (GA) has been encoded in MATLAB to generate seed distributions for a simplified prostate and urethra model. To assess the quality of the seed distributions created by the GA, both the GA and IPSA were used to generate seed distributions for two clinically relevant scenarios and the quality of the GA distributions relative to IPSA distributions and clinically accepted standards for seed distributions was investigated. The first clinically relevant scenario involved generating seed distributions for three different prostate volumes (19.2 cc, 32.4 cc, and 54.7 cc). The second scenario involved generating distributions for three separate seed activities (0.397 mCi, 0.455 mCi, and 0.5 mCi). Both GA and IPSA met the clinically accepted criteria for the two scenarios, where distributions produced by the GA were comparable to IPSA in terms of full coverage of the prostate by the prescribed dose, and minimized dose to the urethra, which passed straight through the prostate. Further, the GA offered improved reduction of high dose regions (i.e hot spots) within the planned target volume. © 2012 American Association of Physicists in Medicine.

  14. SU-G-IeP4-14: Prostate Brachytherapy Activity Measurement and Source Localization by Using a Dual Photon Emission Computed Tomography System: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Lin, C; Lin, H; Chuang, K; Chiang, C [National Tsing Hua University, Hsinchu, Taiwan (China); Tsai, Y [National Taiwan University Hospital, Taipei City, Taiwan (China)

    2016-06-15

    Purpose: To monitor the activity distribution and needle position during and after implantation in operating rooms. Methods: Simulation studies were conducted to assess the feasibility of measurement activity distribution and seed localization using the DuPECT system. The system consists of a LaBr3-based probe and planar detection heads, a collimation system, and a coincidence circuit. The two heads can be manipulated independently. Simplified Yb-169 brachytherapy seeds were used. A water-filled cylindrical phantom with a 40-mm diameter and 40-mm length was used to model a simplified prostate of the Asian man. Two simplified seeds were placed at a radial distance of 10 mm and tangential distance of 10 mm from the center of the phantom. The probe head was arranged perpendicular to the planar head. Results of various imaging durations were analyzed and the accuracy of the seed localization was assessed by calculating the centroid of the seed. Results: The reconstructed images indicate that the DuPECT can measure the activity distribution and locate the seeds dwelt in different positions intraoperatively. The calculated centroid on average turned out to be accurate within the pixel size of 0.5 mm. The two sources were identified when the duration is longer than 15 s. The sensitivity measured in water was merely 0.07 cps/MBq. Conclusion: Preliminary results show that the measurement of the activity distribution and seed localization are feasible using the DuPECT system intraoperatively. It indicates the DuPECT system has potential to be an approach for dose-distribution-validation. The efficacy of acvtivity distribution measurement and source localization using the DuPECT system will evaluated in more realistic phantom studies (e.g., various attenuation materials and greater number of seeds) in the future investigation.

  15. Dosimetry of indigenously developed 192Ir high-dose rate brachytherapy source: An EGSnrc Monte Carlo study

    Directory of Open Access Journals (Sweden)

    Sridhar Sahoo

    2016-01-01

    Full Text Available Clinical application using high-dose rate (HDR 192Ir sources in remote afterloading technique is a well-established treatment method. In this direction, Board of Radiation and Isotope Technology (BRIT and Bhabha Atomic Research Centre, India, jointly indigenously developed a remote afterloading machine and 192Ir HDR source. The two-dimensional (2D dose distribution and dosimetric parameters of the BRIT 192Ir HDR source are generated using EGSnrc Monte Carlo code system in a 40 cm dia × 40 cm height cylindrical water phantom. The values of air-kerma strength and dose rate constant for BRIT 192Ir HDR source are 9.894 × 10−8 ± 0.06% UBq−1 and 1.112 ± 0.11% cGyh−1U−1, respectively. The values of radial dose function (gL(r of this source compare well with the corresponding values of BEBIG, Flexisource, and GammaMed 12i source models. This is because of identical active lengths of the sources (3.5 mm and the comparable phantom dimensions. A comparison of gL(r values of BRIT source with microSelectron-v1 show differences about 2% at r = 6 cm and up to 13% at r = 12 cm, which is due to differences in phantom dimensions involved in the calculations. The anisotropy function of BRIT 192Ir HDR source is comparable with the corresponding values of microSelectron-v1 (classic HDR source.

  16. Resolving the brachytherapy challenges with government funded hospital.

    Science.gov (United States)

    Nikam, D S; Jagtap, A S; Vinothraj, R

    2016-01-01

    The objective of this study is to rationalize the feasibility and cost-effectiveness of high dose rate (HDR) cobalt 60 (Co-60) source versus 192-Iridium (192-Ir) source brachytherapy in government funded hospitals and treatment interruption gap because of exchange of sources. A retrospective study of gynecological cancer patients, treated by radiotherapy with curative intent between April 2005 and September 2012 was conducted. We analyzed the total number of patients treated for external beam radiotherapy (EBRT) and brachytherapy (Intracavitary brachytherapy or cylindrical vaginal source). The dates for 192-Ir sources installation and the last date and first date of brachytherapy procedure before and after source installation respectively were also analyzed and calculated the gap in days for brachytherapy interruptions. The study was analyzed the records of 2005 to September 2012 year where eight 192-Ir sources were installed. The mean gap between treatment interruptions was 123.12 days (range 1-647 days). The Institutional incidence of gynecological cancer where radiotherapy was treatment modality (except ovary) is 34.9 percent. Around 52.25 percent of patients who received EBRT at this institute were referred to outside hospital for brachytherapy because of unavailability of Iridium source. The cost for 5 year duration for single cobalt source is approximately 20-22 lakhs while for 15 Iridium sources is approximately 52-53 lakhs. The combined HDR Co-60 brachytherapy and EBRT provide a useful modality in the treatment of gynecological cancer where radiotherapy is indicated, the treatment interruption because of source exchange is longer and can be minimized by using cobalt source as it is cost-effective and has 5 year working life. Thus, Co-60 source for brachytherapy is a feasible option for government funded hospitals in developing countries.

  17. Calculation of integrated biological response in brachytherapy

    International Nuclear Information System (INIS)

    Dale, Roger G.; Coles, Ian P.; Deehan, Charles; O'Donoghue, Joseph A.

    1997-01-01

    Purpose: To present analytical methods for calculating or estimating the integrated biological response in brachytherapy applications, and which allow for the presence of dose gradients. Methods and Materials: The approach uses linear-quadratic (LQ) formulations to identify an equivalent biologically effective dose (BED eq ) which, if applied to a specified tissue volume, would produce the same biological effect as that achieved by a given brachytherapy application. For simple geometrical cases, BED multiplying factors have been derived which allow the equivalent BED for tumors to be estimated from a single BED value calculated at a dose reference point. For more complex brachytherapy applications a voxel-by-voxel determination of the equivalent BED will be more accurate. Equations are derived which when incorporated into brachytherapy software would facilitate such a process. Results: At both high and low dose rates, the BEDs calculated at the dose reference point are shown to be lower than the true values by an amount which depends primarily on the magnitude of the prescribed dose; the BED multiplying factors are higher for smaller prescribed doses. The multiplying factors are less dependent on the assumed radiobiological parameters. In most clinical applications involving multiple sources, particularly those in multiplanar arrays, the multiplying factors are likely to be smaller than those derived here for single sources. The overall suggestion is that the radiobiological consequences of dose gradients in well-designed brachytherapy treatments, although important, may be less significant than is sometimes supposed. The modeling exercise also demonstrates that the integrated biological effect associated with fractionated high-dose-rate (FHDR) brachytherapy will usually be different from that for an 'equivalent' continuous low-dose-rate (CLDR) regime. For practical FHDR regimes involving relatively small numbers of fractions, the integrated biological effect to

  18. Advancements in brachytherapy

    DEFF Research Database (Denmark)

    Tanderup, Kari; Ménard, Cynthia; Polgar, Csaba

    2017-01-01

    Brachytherapy is a radiotherapy modality associated with a highly focal dose distribution. Brachytherapy treats the cancer tissue from the inside, and the radiation does not travel through healthy tissue to reach the target as with external beam radiotherapy techniques. The nature of brachytherap...

  19. Definitive Brachytherapy for Kaposi's Sarcoma

    International Nuclear Information System (INIS)

    Williams, A.; Ezzell, G.; Zalupski, M.; Fontanesi, J.

    1996-01-01

    Purpose: To assess the efficacy and possible complications in patients diagnosed with Kaposi's sarcoma and treated with definitive brachytherapy. Methods and Materials: Between January, 1995 and December, 1995, four patients with Kaposi's sarcoma (KS) were treated with brachytherapy. Three patients, all with positive HIV status were treated using Iridium 192 (Ir-192) sources via a high-dose rate remote afterloader. One patient with endemic KS was treated using the application of catheters loaded with Californium 252. Eight sites were treated and included scalp, feet, nose, penis, hand, neck, and back. Dose rate for Ir-192 was 330cGy/fx to a total dose of 990cGy. The Californium was delivered as 100nGy/b.i.d. to a total dose of 900nGy. Follow-up as ranged from 2-6 months. Results: All four patients remain alive. Seven of eight sites have had complete clinical response and each patient has reported durable pain relief that has not subsided through last follow-up of 1/96. Two of eight sites, both treated with surface mold technique with Californium 252 developed moist desquamation. The remaining six sites did not demonstrate significant toxicity. Conclusion: Brachytherapy can offer Kaposi's sarcoma patients results that are equivalent to external beam radiation therapy, with minimal complications, a shorter treatment time and potential cost effectiveness

  20. Divergence of Cs-137 sources fluence used in brachytherapy; Divergencia da fluencia de fontes de Cs-137 usadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Vianello, E.A.; Almeida, C.E. de [Laboratorio de Ciencias Radiologicas- LCR-DBB (UERJ). R. Sao Francisco Xavier, 524- Pav. HLC, sala 136 terreo- CEP 20.550- 013. Rio de Janeiro (Brazil)

    1998-12-31

    In this work the experimental determination of correction factor for fluence divergence (kln) of linear Cs-137 sources CDCS J4, with Farmer ionization chamber model 2571 in a central and perpendicular plan to source axis, for distances range from 1 to 7 cm., has been presented. The experimental results were compared to calculating by Kondo and Randolph (1960) isotropic theory and Bielajew (1990) anisotropic theory. (Author)

  1. [Which modality for prostate brachytherapy?].

    Science.gov (United States)

    Bossi, A

    2010-10-01

    Brachytherapy techniques by permanent implant of radioactive sources or by temporary high-dose-rate (HDR) fractions are nowadays extensively used for the treatment of prostatic carcinoma. Long-term results (at 20 years) concerning large amount of patients have been published by major centers confirming both in terms of efficacy and toxicities that permanent implant of radioactive iodine-125 seeds yields at least the same good results of surgery and of external beam irradiation when proposed to patients affected by low-risk disease. For intermediate to high-risk tumors, HDR temporary implants are proposed as a boost for dose escalation. For both techniques, several topics still need to be clarified dealing with a recent enlargement of indications (HDR alone for low-risk, iodine-125 seeds boost for intermediate-high-risk cancers), or with technical aspects (loose seeds versus linked ones, number of fractions and dose for HDR protocols), while dosimetric issues have only recently been addressed by cooperatives groups. Last but not least, there is a real need to address and clearly characterize the correct definition of biochemical disease control both for iodine permanent implant and for HDR implant. New challenges are facing the prostate-brachytherapy community in the near future: local relapse after external beam radiotherapy are currently managed by several salvage treatments (prostatectomy, cryo, high intensity focused ultrasounds [HIFU]) but the role of reirradiation by brachytherapy is also actively investigated. Focal therapy has gained considerable interest in the last 5 years aiming at treating only the area of cancer foci inside the prostate and preserving nearby healthy tissues. Encouraging results have been obtained with the so-called "minimally invasive" approaches and both permanent seed implantation and HDR brachytherapy techniques may be worthwhile testing in this setting because of their capability of exactly sculpting the dose inside the prostatic

  2. Dynamic rotating-shield brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yunlong [Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center, Iowa City, Iowa 52242 (United States); Flynn, Ryan T.; Kim, Yusung [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States); Yang, Wenjun [Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, Wisconsin 53705 (United States); Wu, Xiaodong [Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center, Iowa City, Iowa 52242 and Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States)

    2013-12-15

    Purpose: To present dynamic rotating shield brachytherapy (D-RSBT), a novel form of high-dose-rate brachytherapy (HDR-BT) with electronic brachytherapy source, where the radiation shield is capable of changing emission angles during the radiation delivery process.Methods: A D-RSBT system uses two layers of independently rotating tungsten alloy shields, each with a 180° azimuthal emission angle. The D-RSBT planning is separated into two stages: anchor plan optimization and optimal sequencing. In the anchor plan optimization, anchor plans are generated by maximizing the D{sub 90} for the high-risk clinical-tumor-volume (HR-CTV) assuming a fixed azimuthal emission angle of 11.25°. In the optimal sequencing, treatment plans that most closely approximate the anchor plans under the delivery-time constraint will be efficiently computed. Treatment plans for five cervical cancer patients were generated for D-RSBT, single-shield RSBT (S-RSBT), and {sup 192}Ir-based intracavitary brachytherapy with supplementary interstitial brachytherapy (IS + ICBT) assuming five treatment fractions. External beam radiotherapy doses of 45 Gy in 25 fractions of 1.8 Gy each were accounted for. The high-risk clinical target volume (HR-CTV) doses were escalated such that the D{sub 2cc} of the rectum, sigmoid colon, or bladder reached its tolerance equivalent dose in 2 Gy fractions (EQD2 with α/β= 3 Gy) of 75 Gy, 75 Gy, or 90 Gy, respectively.Results: For the patients considered, IS + ICBT had an average total dwell time of 5.7 minutes/fraction (min/fx) assuming a 10 Ci{sup 192}Ir source, and the average HR-CTV D{sub 90} was 78.9 Gy. In order to match the HR-CTV D{sub 90} of IS + ICBT, D-RSBT required an average of 10.1 min/fx more delivery time, and S-RSBT required 6.7 min/fx more. If an additional 20 min/fx of delivery time is allowed beyond that of the IS + ICBT case, D-RSBT and S-RSBT increased the HR-CTV D{sub 90} above IS + ICBT by an average of 16.3 Gy and 9.1 Gy, respectively

  3. Determination of factors through Monte Carlo method for Fricke dosimetry from {sup 192}Ir sources for brachytherapy; Determinacao por Monte Carlo de fatores para dosimetria Fricke de fontes de {sup 192}Ir para braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    David, Mariano Gazineu; Salata, Camila; Almeida, Carlos Eduardo, E-mail: marianogd08@gmail.com [Universidade do Estado do Rio de Janeiro (UERJ/LCR), Rio de Janeiro (Brazil). Lab. de Ciencias Radiologicas

    2014-07-01

    The Laboratorio de Ciencias Radiologicas develops a methodology for the determination of the absorbed dose to water by Fricke chemical dosimetry method for brachytherapy sources of {sup 192}Ir high dose rate and have compared their results with the laboratory of the National Research Council Canada. This paper describes the determination of the correction factors by Monte Carlo method, with the Penelope code. Values for all factors are presented, with a maximum difference of 0.22% for their determination by an alternative way. (author)

  4. Brachytherapy in lip cancer.

    Science.gov (United States)

    Rovirosa-Casino, Angeles; Planas-Toledano, Isabel; Ferre-Jorge, Jorge; Oliva-Díez, José María; Conill-Llobet, Carlos; Arenas-Prat, Meritxell

    2006-05-01

    Lip cancer is one of the most prevalent skin tumours of the head and neck. The characteristics of the tumour relate to their exophyitic growth in an area of easy visual acces which allows their diagnosis in early stages. As a result, there is a better prognosis with the present treatments. In early stages the treatment can be performed by surgery or by brachytherapy, and the results are similar on local control; nevertheless brachytherapy offers the best functional and esthetic results. We are reporting on a review of the literature in relation to indications, techniques and results of brachytherapy for lip cancer.

  5. An assessment of the radiological impact of brachytherapy application in Metro Manila hospitals

    International Nuclear Information System (INIS)

    Palattao, M.V.B.; Venida, L.L.; Loterina, R.A.; Espiritu, R.T.

    1996-01-01

    One of the most important uses of radioactive sources in medicine is the application of brachytherapy technology. Brachytherapy is a method of radiation therapy where an encapsulated radioactive source delivers gamma or beta radiation into a tumor site. The paper describes different categories of brachytherapy applications involving manual insertion or afterloading and remote afterloading techniques. A list of five hospitals in Metro Manila practicing different techniques of brachytherapy are enumerated. Because of the widespread uses of radioactive sources in brachytherapy technology in medicine, inadequate control in its use had led to a number of incidents resulting to unnecessary exposure of radiation workers, patients and general public. This study was initiated to determine the radilogical hazards involved in brachytherapy applications. It presents contingency scenarios and their projected radiological consequences. (author). 7 refs., 2 tabs

  6. Radiation protection in brachytherapy

    International Nuclear Information System (INIS)

    Benitez, Manuel

    1996-02-01

    It covers technical procedures in medical applications for cancer treatment. Radiation protection principles in brachytherapy. Medical uses in therapy for Sr-90, Cs-137, Co-60, Ra-226, Ir-192, Au-198, Bi-214, Pb-214. (The author)

  7. The American College of Radiology and the American Brachytherapy Society practice parameter for the performance of radionuclide-based high-dose-rate brachytherapy.

    Science.gov (United States)

    Erickson, Beth A; Bittner, Nathan H J; Chadha, Manjeet; Mourtada, Firas; Demanes, D Jeffrey

    Brachytherapy is a radiation therapy method in which radionuclide sources are used to deliver a radiation dose at a distance of up to a few centimeters by surface, intracavitary, intraluminal, or interstitial application. This practice parameter refers only to the use of radionuclides for brachytherapy. Brachytherapy alone or combined with external beam therapy plays an important role in the management and treatment of patients with cancer. High-dose-rate (HDR) brachytherapy uses radionuclides such as iridium-192 at dose rates of 20 cGy per minute (12 Gy per hour) or more to a designated target point or volume. High-dose-rate (HDR) brachytherapy is indicated for treating malignant or benign tumors where the treatment volume or targeted points are defined and accessible. Copyright © 2016 American Brachytherapy Society and American College of Radiology. Published by Elsevier Inc. All rights reserved.

  8. The dosimetry of brachytherapy-induced erectile dysfunction

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.

    2003-01-01

    There is emerging evidence that brachytherapy-induced erectile dysfunction (ED) is technique-related and may be minimized by careful attention to source placement. Herein, we review the relationship between radiation doses to the prostate gland/surrounding structures and the development of brachytherapy-induced ED. The permanent prostate brachytherapy literature was reviewed using MEDLINE searches to ensure completeness. Although the site-specific structure associated with brachytherapy-induced ED remains unknown, there is an increasing body of data implicating the proximal penis. With day 0 CT-based dosimetry, the dose to 50% (D 50 ) and 25% (D 25 ) of the bulb of the penis should be maintained below 40% and 60% mPD, respectively, while the crura D 50 should be maintained below 28% mPD to maximize post-brachytherapy potency. To date, there is no data to suggest that either radiation doses to the neurovascular bundles or choice of isotope is associated with brachytherapy-induced ED, while conflicting data has been reported regarding radiation dose to the prostate and the use of supplemental external beam radiation therapy. Although the etiology of brachytherapy-induced ED is likely multifactorial, the available data supports the proximal penis as an important site-specific structure. Refinements in implant technique, including preplanning and intraoperative seed placement, will result in lower radiation doses to the proximal penis with potential improvement in potency preservation

  9. Comparison between methods for fixing radioactive iodine in silver substrate for manufacturing brachytherapy sources; Comparacao entre metodos de fixacao do iodo radioativo em substrato de prata para confeccao de fontes utilizadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Carla Daruich

    2012-07-01

    Among the different ways to treat prostate cancer, brachytherapy with iodine- 125 seeds is an option that provides good results and fewer side effects. In the present study several deposition methods of radioactive iodine in a silver substrate were compared in order to choose the most suitable alternative for the routine production to be implemented at IPEN's laboratory. The methodology used was chosen based on the available infrastructure and experience of the researchers present. Therefore, the {sup 131}I was used for testing (same chemical behavior as {sup 131}I). Four methods were selected: Method 1 (test based on electrodeposition method developed by D.Kubiatowicz) presented 65.16% efficiency; Method 2 (chemical reaction based on the method developed by D. Kubiatowicz - HCl) with the result of 70.80% efficiency; method 3 (chemical reaction based on the method developed by Dr. Maria Elisa Rostelato) with 55.80% efficiency; Method 4 (IQ-IPEN) resulted in 99% efficiency. Since this method has more radioactive material fixation (which represents virtually the entire cost of the seed), the final price is the cheapest. This method is the suggested one to be implemented in the IPEN's laboratory for brachytherapy sources production. Besides, the method is the fasted one. (author)

  10. Determination of the chemical yield on the Fricke dosimetry for {sup 192}Ir sources used in brachytherapy; Determinacao do rendimento quimico na dosimetria Fricke para fontes de {sup 192}Ir usadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    David, M.G.; Albuquerque, M.A.G.; Almeida, C.E. de, E-mail: marianogd08@gmail.com [Universidade do Estado do Rio de Janeiro (LCR/UERJ), Rio de Janeiro, RJ (Brazil). Lab. de Ciencias Radiologicas; Salata, C. [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Rosado, P.H. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    With the aim of developing a primary standard for the absorbed dose to water, for the {sup 192}Ir sources used in high dose rate brachytherapy, this work focuses on the determination of the chemical yield, G(Fe{sup +3}), using Fricke dosimetry, for the energy of those sources . The G(Fe{sup +3}) were determined the for three qualities of x-ray beams (150, 250 and 300 kV ) and for {sup 60}Co energy. The G(Fe{sup +3}) value for the average energy of {sup 192}Ir was obtained by linear fit, the found value was 1,555 ± 0,015 μmol/J. (author)

  11. Dosimetry in high dose rate endoluminal brachytherapy

    International Nuclear Information System (INIS)

    Uno, Takashi; Kotaka, Kikuo; Itami, Jun

    1994-01-01

    In endoluminal brachytherapy for the tracheobronchial tree, esophagus, and bile duct, a reference point for dose calculation has been often settled at 1 cm outside from the middle of source travel path. In the current study, a change in the ratio of the reference point dose on the convex to concave side (Dq/Dp) was calculated, provided the source travel path bends as is the case in most endoluminal brachytherapies. Point source was presumed to move stepwise at 1 cm interval from 4 to 13 locations. Retention time at each location was calculated by personal computer so as to deliver equal dose at 1 cm from the linear travel path. With the retention time remaining constant, the change of Dq/Dp was assessed by bending the source travel path. Results indicated that the length of the source travel path and radius of its curve influenced the pattern of change in Dq/Dp. Therefore, it was concluded that the difference in reference dose on the convex and concave side of the curved path is not negligible under certain conditions in endoluminal brachytherapy. In order to maintain the ratio more than 0.9, relatively greater radius was required when the source travel path was decreased. (author)

  12. Verification and analysis of the positioning of a source of brachytherapy high dose within an applicator gynecological interstitial fletcher Utrecht TC/RM; Verificacion y analysis del posicionamiento de una fuente de braquiterapia de alta tasa de dosis dentro de un aplicador ginecologico fletcher intersticial UTRECHT TC/RM

    Energy Technology Data Exchange (ETDEWEB)

    Panedo Cobos, J. M.; Garcia castejon, M. A.; Huertas Martinez, C.; Gomez-Tejedor Alonso, S.; Rincon Perez, M.; Luna Tirado, J.; Perez Casas, A. M.

    2013-07-01

    Applicators are guides that circulate and are located within the patient brachytherapy sources. Applicators can suffer mechanical deformations due to processes of sterilization or shock, which may result in that the source do not place within these very precise and coincides with the planned. In these cases the planned treatment deviate actually managed. The object of this study is to verify that the position of the source into the dispenser coincides with the planned position, with a procedure that is described. (Author)

  13. CNS Intravascular Lymphoma: A Case Report

    Directory of Open Access Journals (Sweden)

    Amer Awad

    2011-01-01

    Full Text Available Intravascular lymphoma is a rare but well-described entity. The clinical manifestations are heterogeneous. We report a case of a 59-year-old woman who presented initially with syncope followed by subacute cognitive decline that progressed to minimally conscious state. Shortly after the transfer to our tertiary center the patient died. Brain autopsy disclosed the diagnosis of B-cell intravascular lymphoma. We speculate that syncope could be the first manifestation of central nervous system intravascular lymphoma and should be considered in the differential diagnosis of unexplained syncope. In addition, we stress the importance of early brain biopsy in unexplained white matter disease.

  14. BRIT manual after loading brachytherapy kit for intracavitary: initial experience

    International Nuclear Information System (INIS)

    Aggarwal, Lalit M.; Mandal, Abhijit; Asthana, Anupam K.; Shahi, Uday P.; Pradhan, Satyajit

    2007-01-01

    Brachytherapy continues to serve as an important and rapidly evolving tool in the management of cancer. Technological developments in the last two decades have dramatic impact on the safe practice of brachytherapy. A wide range of brachytherapy sources and equipment are available for new therapeutic possibilities. However, decision making with regard to new brachytherapy facilities are need based and depend on the patient load, socioeconomic status of the patients, and funds available with the institution. Remote afterloading equipments are fast replacing the Manual After Loading (MAL) systems. However, keeping in view the large number of patients, who can not afford expensive treatment, the utility of manual after loading system which is inexpensive, cannot be ignored

  15. A preliminary analysis of health-related quality of life in the first year after permanent source interstitial brachytherapy (PIB) for clinically localized prostate cancer

    International Nuclear Information System (INIS)

    Lee, W. Robert; McQuellon, Richard P.; Harris-Henderson, Kesha; Case, L. Doug; McCullough, David L.

    2000-01-01

    Purpose: To prospectively assess the health-related quality of life (HRQOL) and changes in HRQOL during the first year after permanent source interstitial brachytherapy (PIB). Methods and Materials: Thirty-one men treated with PIB between September 1997 and March 1998 completed a quality of life (functional assessment of cancer therapy-prostate: FACT-P) and a urinary symptom questionnaire (international prostate symptom score: IPSS) prior to treatment (T0), 1 month (T1), 3 months (T3), 6 months (T6), and 12 months (T12) following PIB. All participants were treated with 125 I alone. Repeated measures analyses of variance (ANOVA) were conducted on all quality of life and urinary outcome measures for all 31 patients at all time points. Results: The median age of the study population was 66 (range 51-80). All men had clinical T1c-T2b prostate cancer. The Gleason score was ≤ 6 in 27/31 (87%). Median pretreatment PSA was 7.8 ng/ml (range 1.1-20.6). The mean score (and standard deviation) at T0, T1, T3, T6, and T12 for the FACT-P questionnaire are as follows: 140.5 (13.5), 132.7 (15.3), 137.2 (17.4), 140.1 (16.0), and 142.4 (15.3). For the global test across time, statistically significant differences were observed for the cumulative scores of FACT-P (p < 0.0012). The decrease in HRQOL was most marked 1 month following PIB. Examination of the subscales within the FACT-P instrument demonstrated statistically significant changes over time for the following: physical well-being (PWB), functional well-being (FWB), and prostate cancer (PCS). By 3 months, all HRQOL measures had returned to near baseline. The mean score (and standard deviation) at T0, T1, T3, T6, and T12 for the IPSS questionnaire are as follows: 8.3 (5.5), 18.4 (8.0), 15.7 (7.4), 13.7 (7.4), and 10.2 (5.7). For the global test across time, statistically significant differences were observed for the IPSS scores (p < 0.0001). The maximum increase in IPSS occurred 1 month following PIB. Conclusion: The results

  16. Potential brachytherapy nuclides of future

    International Nuclear Information System (INIS)

    Shanta, A.; Iyer, P.S.

    1993-01-01

    In the past there were relatively few radionuclides available for brachytherapy. But the situation is rapidly changing with the development of many new sources with properties that may be advantageous in certain clinical situations. In the choice of an acceptable, rather than an ideal radionuclide, it is important to consider the physical dose distribution, radiobiological effectiveness, ease of radiation protection, logistics and cost. Taking into account these factors, a number of radionuclides have been tried and more are being considered for specific type of applications. Presently, 137 Cs is the most commonly used radionuclide for intracavitary therapy and 192 Ir for interstitial therapy. 125 I has more or less replaced 198 Au for permanent implants. Clinical studies are being carried out to assess the feasibility of replacing 137 Cs with 241 Am for intracavitary applications and 125 I with 103 Pd and/or 169 Yb for interstitial permanent implants. Other radionuclides being considered are 75 Fe and 145 Sm. Neutron induced brachytherapy is a new technique being tried to ensure complete radiation safety. (author). 1 tab

  17. Intravascular lipoma of the renal vein

    Directory of Open Access Journals (Sweden)

    Z Doyle

    2015-06-01

    Full Text Available Lipomas are benign neoplasms composed of adipocytes encased in a fibrous capsule. Intravascular lipomas are rare and almost always incidental findings. In the published literature, the majority are described within the inferior vena cava (IVC and less frequently reported in the superior vena cava, brachiocephalic vein, subclavian vein, internal jugular vein, external iliac vein and common femoral vein. We present the case of a 59-year-old male who presented with a symptomatic ureteral calculus and was found to have an intravascular lipoma of the right renal vein with extension into the IVC. To our knowledge, this is the first ever report of an intravascular lipoma in the renal vein. We discuss the imaging characteristics of intravascular lipomas and the differential diagnosis that should be considered.

  18. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    OpenAIRE

    Kensuke Tashiro, MD; Shuji Yamashita, MD; Mitsunaga Narushima, MD; Isao Koshima, MD; Shimpei Miyamoto, MD

    2017-01-01

    Background:. Although supermicrosurgical anastomosis is a widely known reconstructive microsurgical technique, it is difficult to perform. To expand the clinical use of supermicrosurgery, we used hemi-intravascular stenting (hemi-IVaS), which is performed by inserting an intravascular stent into one side of the vessel. We conducted lymphaticovenular anastomosis, free perforator flap transfer, and fingertip replantation with supermicrosurgical anastomosis using hemi-IVaS technique and examined...

  19. Calibration of a {sup 19} {sup 2}Ir source for high dose brachytherapy using various techniques; Calibracion de una fuente de {sup 192} Ir para braquiterapia de alta tasa de dosis mediante diversas tecnicas

    Energy Technology Data Exchange (ETDEWEB)

    Montilla Prieto, Tedicel C., E-mail: tcdicel@gmaiLcam [Instituto de Oncologia Dr. Miguel Perez Carreno, Barbula (Venezuela, Bolivarian Republic of). Departamento de Fisica y Dosimetria; Padron Rivero, Alvaro D., E-mail: alvarodpadronr@yahoo.com.ve [Universidad de Carabobo, Barbula (Venezuela, Bolivarian Republic of). Facultad de Ciencias de la Salud. Departamento de Ciencias Fisiologicas

    2013-10-01

    In this research we studied three experimental procedures for calibration of a source of {sup 192}Ir to high dose rate for clinical brachytherapy use, and thus were compared and analysis of the advantages and disadvantages of each. For this study we quantified the value of the current kerma rate reference in air by three procedures: source calibration using a well chamber, with an cylindrical ionization chamber in air, and a cylindrical ionization chamber on a phantom, and this magnitude was compared with the value provided by the manufacturer of the source and thereby obtaining the deviation corresponding . Thus, it was found that the deviation corresponding to the source calibration making use of a well chamber, remained within tolerance, while the cylindrical ionization chamber in air and on phantom exceeded the standards established in some documents. However, although both the measurement in air and in the phantom are the procedures for the final calibration source, these can be used to verify that the delivered dose are in tolerance.

  20. MO-B-BRC-01: Introduction [Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Prisciandaro, J. [University of Michigan (United States)

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  1. Imaging method for monitoring delivery of high dose rate brachytherapy

    Science.gov (United States)

    Weisenberger, Andrew G; Majewski, Stanislaw

    2012-10-23

    A method for in-situ monitoring both the balloon/cavity and the radioactive source in brachytherapy treatment utilizing using at least one pair of miniature gamma cameras to acquire separate images of: 1) the radioactive source as it is moved in the tumor volume during brachytherapy; and 2) a relatively low intensity radiation source produced by either an injected radiopharmaceutical rendering cancerous tissue visible or from a radioactive solution filling a balloon surgically implanted into the cavity formed by the surgical resection of a tumor.

  2. Evaluation of the response of modified MAGIC-f polymeric gel using a clinical brachytherapy source and Monte Carlo simulation with package PENELOPE; Avaliacao da resposta do gel polimerico MAGIC-f modificado utilizando uma fonte clinica de braquiterapia e simulacao Monte Carlo com o pacote PENELOPE

    Energy Technology Data Exchange (ETDEWEB)

    Quevedo, Ana Luiza; Nicolucci, Patricia, E-mail: anaquevedo@usp.br [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Dept. de Fisica; Borges, Leandro F. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Setor de Radioterapia

    2016-07-01

    A comparison of experimental and simulated relative doses of a clinical brachytherapy source was performed. A 5 x 5 x 7 cm{sup 3} phantom with a modified MAGIC-f gel was irradiated using a clinical {sup 192}Ir source, Varian, model GammaMed Plus. The phantom was irradiated with 7,5 Gy, commonly used in gynecological treatments. The dose distributions readings were performed 24h after irradiation using Magnetic Resonance Imaging, weighted in T2, with repetition time of 6000 ms, echo-time of 15 ms, 16 echos and 0.40 mm pixel size. The same brachytherapy source was modeled in the Monte Carlo package PENELOPE to obtain dose distributions. The energy cutoff for electrons, photons and positrons was 100 keV, the primary particles condensation parameters remained the same at 0.3. The dose distributions were obtained in two planes perpendicular to the source: one passing through the source’s center and the other at 0.5 cm away from the source’s center in direction of the top of encapsulation. A comparison of the experimental results using the polymeric gel to the computational results showed maximum differences of 12.5%, at 0.62 cm from the source for the central plane, and 6.4% at 0.5 cm from the source for the superior plane. Considering the high dose gradient of these clinical brachytherapy sources, the results obtained in these work show that MAGIC-f gel with modified formulation, is promising for dosimetry in brachytherapy. (author)

  3. Coagulación intravascular diseminada = Disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Arango Barrientos, Marcos

    2010-12-01

    Full Text Available La coagulación intravascular diseminada (CID es una entidad clínica frecuente que se presenta como fenómeno secundario a diversas enfermedades entre las cuales se destacan las infecciones graves, las neoplasias y las catástrofes obstétricas. Se caracteriza por una activación difusa y simultánea de los sistemas endógenos de la coagulación y la fibrinólisis. El depósito de pequeños trombos en la circulación conduce finalmente a disfunción orgánica múltiple y en algunos casos a la muerte. Las manifestaciones clínicas pueden incluir fenómenos trombóticos y hemorrágicos. Se ha propuesto un puntaje de fácil aplicación para simplificar el diagnóstico de la entidad. El tratamiento incluye el control específico de la causa subyacente que favorece la aparición de la CID, el soporte con hemoderivados en pacientes con manifestaciones de sangrado y la anticoagulación terapéutica en pacientes con trombosis mayores. El desarrollo de CID es un factor pronóstico adverso que aumenta significativamente la tasa de mortalidad. En este artículo de revisión se incluyen los siguientes aspectos de la CID: historia, epidemiología, clasificación, entidades asociadas, fisiopatología, clínica, diagnóstico, tratamiento y pronóstico.

  4. Preparation and determination of kerma for Iridium 192 sources of low dose rate for brachytherapy; Preparacion y determinacion del kerma de fuentes de iridio-192 de baja tasa de dosis para braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Tendilla, J.I.; Tovar M, V.; Mitsoura, E.; Aguilar H, F.; Alanis M, J. [Instituto Nacional de Investigaciones Nucleares, C.P. 52045-1, Salazar, Esrado de Mexico, D.F. (Mexico)

    2000-07-01

    The practice of Brachytherapy with Iridium-192 sources of low dose rate (0.4 - 0.8 Gy/h) is a technique used in the treatment of diverse illnesses. in this work the preparation, quality control and calibration are presented in terms of kerma in air of Iridium-192 using as target these recycled Iridium-Platinum wires. The targets were obtained as decayed sources of different radio therapeutical centers in the country and they were characterized by Scanning electron microscopy in order to determine their chemical composition. Subsequently it was developed an experimental design to establish the effect of neutron flux, geometrical array and irradiation time over the activity and percentage of the sources homogeneity. The homogeneity was determined by auto radiography and by Gamma spectroscopy. Once the optimal irradiation conditions were established, it is determined the apparent activity and kerma in air using a well type ionization chamber with traceability to a primary laboratory. Iridium-192 sources were obtained with an average homogeneity 96 %, apparent activity 282.129 {+-} 0.531 M Bq and kerma in air 0.03200 {+-} 0.00006 m Gy m/h A. (Author)

  5. Histamine release and endothelial leakage from an intravascular contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Raininko, R.

    1981-04-01

    The endothelial injury produced by meglumine iodamide was studied in the rat aorta. A mixture of blood and contrast medium was more toxic to the endothelium than the pure contrast agent. This difference disappeared after premedication with antihistamine, which did not affect the injury produced by the pure contrast agent. Meglumine iodamide appears to cause a release of histamine from blood but not from the aortic endothelium nor from surrounding tissues in amounts demonstrable by this method. Leucocytes are a source of histamine after intravascular contrast medium administration.

  6. SU-D-19A-05: The Dosimetric Impact of Using Xoft Axxent® Electronic Brachytherapy Source TG-43 Dosimetry Parameters for Treatment with the Xoft 30 Mm Diameter Vaginal Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Simiele, S; Micka, J; Culberson, W; DeWerd, L [University of WI-Madison/ADCL, Madison, WI (United States)

    2014-06-01

    Purpose: A full TG-43 dosimetric characterization has not been performed for the Xoft Axxent ® electronic brachytherapy source (Xoft, a subsidiary of iCAD, San Jose, CA) within the Xoft 30 mm diameter vaginal applicator. Currently, dose calculations are performed using the bare-source TG-43 parameters and do not account for the presence of the applicator. This work focuses on determining the difference between the bare-source and sourcein- applicator TG-43 parameters. Both the radial dose function (RDF) and polar anisotropy function (PAF) were computationally determined for the source-in-applicator and bare-source models to determine the impact of using the bare-source dosimetry data. Methods: MCNP5 was used to model the source and the Xoft 30 mm diameter vaginal applicator. All simulations were performed using 0.84p and 0.03e cross section libraries. All models were developed based on specifications provided by Xoft. The applicator is made of a proprietary polymer material and simulations were performed using the most conservative chemical composition. An F6 collision-kerma tally was used to determine the RDF and PAF values in water at various dwell positions. The RDF values were normalized to 2.0 cm from the source to accommodate the applicator radius. Source-in-applicator results were compared with bare-source results from this work as well as published baresource results. Results: For a 0 mm source pullback distance, the updated bare-source model and source-in-applicator RDF values differ by 2% at 3 cm and 4% at 5 cm. The largest PAF disagreements were observed at the distal end of the source and applicator with up to 17% disagreement at 2 cm and 8% at 8 cm. The bare-source model had RDF values within 2.6% of the published TG-43 data and PAF results within 7.2% at 2 cm. Conclusion: Results indicate that notable differences exist between the bare-source and source-in-applicator TG-43 simulated parameters. Xoft Inc. provided partial funding for this work.

  7. SU-D-19A-05: The Dosimetric Impact of Using Xoft Axxent® Electronic Brachytherapy Source TG-43 Dosimetry Parameters for Treatment with the Xoft 30 Mm Diameter Vaginal Applicator

    International Nuclear Information System (INIS)

    Simiele, S; Micka, J; Culberson, W; DeWerd, L

    2014-01-01

    Purpose: A full TG-43 dosimetric characterization has not been performed for the Xoft Axxent ® electronic brachytherapy source (Xoft, a subsidiary of iCAD, San Jose, CA) within the Xoft 30 mm diameter vaginal applicator. Currently, dose calculations are performed using the bare-source TG-43 parameters and do not account for the presence of the applicator. This work focuses on determining the difference between the bare-source and sourcein- applicator TG-43 parameters. Both the radial dose function (RDF) and polar anisotropy function (PAF) were computationally determined for the source-in-applicator and bare-source models to determine the impact of using the bare-source dosimetry data. Methods: MCNP5 was used to model the source and the Xoft 30 mm diameter vaginal applicator. All simulations were performed using 0.84p and 0.03e cross section libraries. All models were developed based on specifications provided by Xoft. The applicator is made of a proprietary polymer material and simulations were performed using the most conservative chemical composition. An F6 collision-kerma tally was used to determine the RDF and PAF values in water at various dwell positions. The RDF values were normalized to 2.0 cm from the source to accommodate the applicator radius. Source-in-applicator results were compared with bare-source results from this work as well as published baresource results. Results: For a 0 mm source pullback distance, the updated bare-source model and source-in-applicator RDF values differ by 2% at 3 cm and 4% at 5 cm. The largest PAF disagreements were observed at the distal end of the source and applicator with up to 17% disagreement at 2 cm and 8% at 8 cm. The bare-source model had RDF values within 2.6% of the published TG-43 data and PAF results within 7.2% at 2 cm. Conclusion: Results indicate that notable differences exist between the bare-source and source-in-applicator TG-43 simulated parameters. Xoft Inc. provided partial funding for this work

  8. The evolution of brachytherapy treatment planning

    International Nuclear Information System (INIS)

    Rivard, Mark J.; Venselaar, Jack L. M.; Beaulieu, Luc

    2009-01-01

    Brachytherapy is a mature treatment modality that has benefited from technological advances. Treatment planning has advanced from simple lookup tables to complex, computer-based dose-calculation algorithms. The current approach is based on the AAPM TG-43 formalism with recent advances in acquiring single-source dose distributions. However, this formalism has clinically relevant limitations for calculating patient dose. Dose-calculation algorithms are being developed based on Monte Carlo methods, collapsed cone, and solving the linear Boltzmann transport equation. In addition to improved dose-calculation tools, planning systems and brachytherapy treatment planning will account for material heterogeneities, scatter conditions, radiobiology, and image guidance. The AAPM, ESTRO, and other professional societies are working to coordinate clinical integration of these advancements. This Vision 20/20 article provides insight into these endeavors.

  9. Transit dose calculation in high dose rate brachytherapy (HDR ...

    African Journals Online (AJOL)

    Transit doses around a high dose rate 192Ir brachytherapy source were calculated using Sievert Integral at positions where the moving source was located exactly between two adjacent dwell positions. The correspond-ing transit dose rates were obtained by using energy absorption coefficients. Discrete step sizes of 0.25 ...

  10. Importance of the neutrons kerma coefficient in the planning of Brachytherapy treatments with Cf-252 sources; Importancia del coeficiente de kerma de neutrones en la planeacion de tratamientos de Braquiterapia con fuentes de Cf-252

    Energy Technology Data Exchange (ETDEWEB)

    Paredes G, L.; Balcazar G, M. [ININ, 52045 Ocoyocac, Estado de Mexico (Mexico); Azorin N, J. [Universidad Autonoma Metropolitana, 09000 Mexico D.F. (Mexico); Francois L, J.L. [UNAM, 04500 Mexico D.F. (Mexico)]. e-mail: lpg@nuclear.inin.mx

    2006-07-01

    The Cf-252 is a fast neutrons emitting radioisotope by spontaneous fission that can be used as sealed source in medicine applications, industry and research. Commercially its offer sources of different sizes, compact and with a fast neutrons emission of the order of 10{sup 6} n/s-{mu}g and an energy spectra that presents respectively maxim and average energy in 2.1 MeV and 0.7 MeV. In medicine new applications are being developed for the treatment of patient with hypoxic and voluminous tumors, where the therapy with photons has not given positive results, as well as for the protocols of therapy treatment by boron neutron capture, where very small sources of Cf-252 will be used with the interstitial brachytherapy technique of high and low dose rate. In this work an analysis of how the small differences that exist in the elementary composition of 4 wicked tumors, 4 ICRU healthy tissues and 3 substitute materials of ICRU tissue used in dosimetry are presented, its generate changes in the neutrons kerma coefficient in function of the energy and consequently in the absorbed dose in the interval of 11 eV to 29 MeV. These differences can produce maximum variations of the neutron kerma coefficients ratio for E{sub n} > 1 keV of the one: 15% tumor/ICRU guest healthy tissue, 12% ICRU tumor/muscle, 12% ICRU healthy tissues ICRU/ICRU muscle, 22% substitutes tissue/tumor and 22% ICRU substitutes tissue/muscle. Also, it was found that the average value of the neutrons kerma coefficient for the 4 wicked tumors is from 6% to 7% smaller that the average value for the soft tissue in the interval energy of interest for therapy with fast neutrons with E{sub n} > 1 MeV. These results have a special importance during the planning process of brachytherapy treatments with sources of {sup 252}Cf, to optimize and to individualize the patients treatments. (Author)

  11. Acute vasculitis after endovascular brachytherapy

    International Nuclear Information System (INIS)

    Fajardo L-G, Luis F.; Prionas, Stavros D.; Kaluza, Grzegorz L.; Raizner, Albert E.

    2002-01-01

    Purpose: Angioplasty effectively relieves coronary artery stenosis but is often followed by restenosis. Endovascular radiation (β or γ) at the time of angioplasty prevents restenosis in a large proportion of vessels in swine (short term) and humans (short and long term). Little information is available about the effects of this radiation exposure beyond the wall of the coronary arteries. Methods and Materials: Samples were obtained from 76 minipigs in the course of several experiments designed to evaluate endovascular brachytherapy: 76 of 114 coronary arteries and 6 of 12 iliac arteries were exposed to endovascular radiation from 32 P sources (35 Gy at 0.5 mm from the intima). Two-thirds of the vessels had angioplasty or stenting. The vessels were systematically examined either at 28 days or at 6 months after radiation. Results: We found an unexpected lesion: acute necrotizing vasculitis in arterioles located ≤2.05 mm from the target artery. It was characterized by fibrinoid necrosis of the wall, often associated with lymphocytic exudates or thrombosis. Based on the review of perpendicular sections of tissue samples, the arterioles had received between 6 and 40 Gy. This arteriolar vasculitis occurred at 28 days in samples from 51% of irradiated coronary arteries and 100% of irradiated iliac arteries. By 6 months, the incidence of acute vasculitis decreased to 24% around the coronary arteries. However, at that time, healing vasculitis was evident, often with luminal narrowing, in 46% of samples. Vasculitis was not seen in any of 44 samples from unirradiated vessels (0%) and had no relation to angioplasty, stenting, or their sequelae. This radiation-associated vasculitis in the swine resembles the localized lymphocytic vasculitis that we have reported in tissues of humans exposed to external radiation. On the other hand, it is quite different from the various types of systemic vasculitis that occur in nonirradiated humans. Conclusion: Endoarterial brachytherapy

  12. Glass microspheres for brachytherapy

    International Nuclear Information System (INIS)

    Prado, Miguel O.; Prastalo, Simon; Blaumann, Herman; Longhino, Juan M.; Repetto Llamazares, A.H.V.

    2007-01-01

    We developed the capacity to produce glass microspheres containing in their structure one or more radioactive isotopes useful for brachytherapy. We studied the various facts related with their production: (Rare earth) alumino silicate glass making, glass characterization, microspheres production, nuclear activation through (n,γ) nuclear reactions, mechanical characterization before and after irradiation. Corrosion tests in simulated human plasma and mechanical properties characterization were done before and after irradiation. (author) [es

  13. Brachytherapy for cancer

    International Nuclear Information System (INIS)

    Nishio, Masamichi; Sakurai, Tomoyasu; Kagami, Yoshikazu; Narimatsu, Naoto

    1987-01-01

    Brachytherapy is one of most effective methods of radiotherapy for cancer, and therefore, low-dose-rate brachytherapy is widely used for carcinoma of the uterus and carcinoma of the tongue. Between 1974 and 1983, 76 primary thoracic esophageal squamous cell carcinomas were treated with external irradiation combined with additional intracavitary radium therapy at the National Sapporo Hospital. The esophageal primary control rate was 34 % and the 5-year survival rate was 24.1 %. We believe that external irradiation therapy followed by additional intracavitary radium irradiation produces good results. Also, from 1982, 30 patients with small residual or unresectable tumors received interstitial irradiation using an after-loading technique and iridium-192 seeds. Eighteen of these 30 patients treated with iridium-192 were recurrent cases, and 20 had outer tubes intra-operatively inserted into the tumor following iridium-192 irradiation. Ten of these patients had brain tumor, nine had cancer of the head and neck, and each of the remaining fifteen had the following malignancies : lung cancer, breast cancer, pancreatic cancer, bile duct cancer, uterus cancer, skin cancer and soft tissue sarcoma. Overall 4-year survival was 17.1 % in among the patients treated with Ir-192. Favorable preliminary results from these patients and those of various clinical trials on the extension of indications for brachytherapy were also reported. (author)

  14. Avaliação da biodegradação de matrizes porosas à base de hidroxiapatita para aplicação como fontes radioativas em braquiterapia Evaluation of the biodegradation of porous hydroxyapatite matrices for application as radioactive sources in brachytherapy

    Directory of Open Access Journals (Sweden)

    Kássio André Lacerda

    2009-01-01

    Full Text Available Porous ceramic materials based on calcium phosphate compounds (CPC have been studied aiming at different biomedical applications such as implants, drug delivery systems and radioactive sources for brachytherapy. Two kinds of hydroxyapatite (HAp powders and their ceramic bodies were characterized by a combination of different techniques (XRF, BET method, SEM, ICP/AES and neutron activation analysis - NAA to evaluate their physico-chemical and microstructural characteristics in terms of chemical composition, segregated phases, microstructure, porosity, chemical and thermal stability, biodegradation and incorporation of substances in their structures. The results revealed that these systems presented potential for use as porous biodegradable radioactive sources able to be loaded with a wide range of radionuclides for cancer treatment by the brachytherapy technique.

  15. Teaching drawn from brachytherapy accidents

    International Nuclear Information System (INIS)

    Pinillos, L.

    2009-01-01

    The first incidents concern the transport of the sources, bad packaging or bad sealing of the sources. The incidents occurring during the use are the most frequent. They come from mechanical problems or human errors as the unit of computer command or the transfer cable of the source. A power failure affected the safety program, causing a calculation error after the input of incorrect data. The most of reported errors occurred during fractionated treatments, so the errors can be compensated by adjusting the doses at the following session. The worst case was the death of a woman where the source stayed inside the body after the treatment. Radiation monitoring in the treatment room should avoid this kind of accident. The brachytherapy represents 500 000 acts by year, any error can be serious. The accident reports concern all the chain of procedure, among them a death whom first cause was a human error. A team respecting the procedures of quality assurance is indispensable to the accident prevention; the accidents report is important because it allows a sharing of lessons drawn from the past errors to prevent from occurring. (N.C.)

  16. Fluorescent Method for Observing Intravascular Bonghan Duct

    Directory of Open Access Journals (Sweden)

    Byung-Cheon Lee

    2005-12-01

    Full Text Available Observation of intra-vascular threadlike structures in the blood vessels of rats is reported with the images by differential interference contrast microscope, and fluorescence inverted microscope of the acridine-orange stained samples. The confocal microscope image and the hematoxylin-eosin staining revealed the distinctive pattern of nuclei distribution that clearly discerned the threadlike structure from fibrin, capillary, small venule, arteriole, or lymph vessel. Physiological function of the intra-vascular thread in connection with acupuncture is discussed. Especially, this threadlike duct can be a circulation path for herb-liquid flow, which may provide the scientific mechanism for therapeutic effect of herbal acupuncture.

  17. Sealed source and device design safety testing: Technical report on the findings of task 4 -- Investigation of failed Nitinol brachytherapy wire. Volume 2

    International Nuclear Information System (INIS)

    Benac, D.J.; Burghard, H.C.

    1996-03-01

    This report covers an investigation of the nature and cause of failure in Nitinol brachytherapy sourcewires. The investigation was initiated after two clinical incidents in which sourcewires failed during or immediately after a treatment. The investigation determined that the two clinical Nitinol sourcewires failed in a brittle manner, which is atypical for Nitinol. There were no material anomalies or subcritical flaws to explain the brittle failures. The bend tests also demonstrated that neither moist environment, radiation, nor low-temperature structural transformation was a likely root cause of the failures. However, degradation of the PTFE was consistently evident, and those sourcewires shipped or stored with PTFE sleeves consistently failed in laboratory bend tests. On the basis of the results of this study, it was concluded that the root cause of the in-service failures of the sourcewires was environmentally induced embrittlement due to the breakdown of the PTFE protective sleeves in the presence of the high-radiation field and subsequent reaction or interaction of the breakdown products with the Nitinol alloy

  18. Neutrophils Cause an Intravascular Traffic Jam.

    Science.gov (United States)

    Minns, Martin S; Pearlman, Eric

    2018-01-10

    Neutrophil swarming is defined by large numbers of cells simultaneously and rapidly migrating to a site of injury or infection. In this issue of Cell Host & Microbe, Lee et al. (2018) demonstrate that intravascular swarming of neutrophils occurs in response to Candida albicans infection and causes vascular occlusion and pathological sequelae. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    Directory of Open Access Journals (Sweden)

    Kensuke Tashiro, MD

    2017-11-01

    Conclusions:. Hemi-IVaS could be a useful alternative to conventional intravascular stenting techniques and is also effective for supermicrosurgical perforator-to-perforator anastomosis. Further studies are needed to improve the success rate and to explore its other possible utilizations in supermicrosurgery.

  20. Intravascular volume after aneurysmal subarachnoid hemorrhage

    NARCIS (Netherlands)

    Hoff, R.G.

    2009-01-01

    Intravascular volume after aneurysmal subarachnoid hemorrhage A subarachnoid hemorrhage (SAH) from a ruptured cerebral aneurysm is a devastating disorder with an often poor prognosis. The occurrence of delayed cerebral ischemia (DCI) is one of the most important factors determining outcome in

  1. Disseminated Intravascular Coagulation Following Induction of ...

    African Journals Online (AJOL)

    Background: Disseminated Intravascular coagulopathy (DIC) has been reported following use of Misoprostol which is an old drug with new indications in Obstetrics and. Gynecology. Its effectiveness, low cost, stability in tropical conditions and ease of administration as well as side effects like gastrointestinal effect, uterine ...

  2. Postal auditing methodology used to find out the performance of high rate brachytherapy equipment

    International Nuclear Information System (INIS)

    Morales, J.A.; Campa, R.

    1998-01-01

    This work describes results from a methodology implemented at the Secondary Laboratory for Dosimetric Calibration at CPHR used to check the brachytherapy performance at high doses rate using Cesium 137 or cobalt 60 sources

  3. Evaluation of the response of polymeric gel modified MAGIC-f using a clinical brachytherapy source and Monte Carlo simulation with package PENELOPE; Avaliacao da resposta do gel polimerico MAGIC-f modificado utilizando uma fonte clinica de braquiterapia e simulacao Monte Carlo com o pacote PENELOPE

    Energy Technology Data Exchange (ETDEWEB)

    Quevedo, Ana Luiza; Nicolucci, Patricia [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia Ciencias e Letras. Dept. de Fisica; Borges, Leandro F. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas. Setor de Radioterapia

    2016-07-01

    In this work a comparison of experimental and simulated relative doses of a clinical brachytherapy source was performed. A 5 x 5 x 7 cm{sup 3} phantom with a modified MAGIC-f gel was irradiated using a clinical {sup 192}Ir source and read using Magnetic Resonance Imaging. The Monte Carlo simulation package PENELOPE was used to simulate the dose distributions of the same radiation source. The dose distributions were obtained in two planes perpendicular to the source: one passing through the source's center and the other at 0.5 cm away from the source's center. The higher differences found between experimental and computational distributions were 12.5% at a point 0.62 cm from the source for the central plane and 8.6% at 1.3 cm from the source to the plane 0.5 cm away from the source's center. Considering the high dose gradient of these dose distributions, the results obtained show that the modified MAGIC-f gel is promising for brachytherapy dosimetry. (author)

  4. Validation of GPUMCD for low-energy brachytherapy seed dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Hissoiny, Sami; Ozell, Benoit; Despres, Philippe; Carrier, Jean-Francois [Ecole polytechnique de Montreal, Departement de genie informatique et genie logiciel, 2500 chemin de Polytechnique, Montreal, QC, H3T 1J4 (Canada); Departement de radio-oncologie, Centre hospitalier universitaire de Quebec (CHUQ), 11 Cote du Palais, Quebec, QC, G1R 2J6 (Canada); Departement de physique, Universite de Montreal, Montreal, QC (Canada) and Departement de radio-oncologie and Centre de recherche du CHUM, Centre hospitalier de l' Universite de Montreal (CHUM), Montreal, QC, H2L 4M1 (Canada)

    2011-07-15

    Purpose: To validate GPUMCD, a new package for fast Monte Carlo dose calculations based on the GPU (graphics processing unit), as a tool for low-energy single seed brachytherapy dosimetry for specific seed models. As the currently accepted method of dose calculation in low-energy brachytherapy computations relies on severe approximations, a Monte Carlo based approach would result in more accurate dose calculations, taking in to consideration the patient anatomy as well as interseed attenuation. The first step is to evaluate the capability of GPUMCD to reproduce low-energy, single source, brachytherapy calculations which could ultimately result in fast and accurate, Monte Carlo based, brachytherapy dose calculations for routine planning. Methods: A mixed geometry engine was integrated to GPUMCD capable of handling parametric as well as voxelized geometries. In order to evaluate GPUMCD for brachytherapy calculations, several dosimetry parameters were computed and compared to values found in the literature. These parameters, defined by the AAPM Task-Group No. 43, are the radial dose function, the 2D anisotropy function, and the dose rate constant. These three parameters were computed for two different brachytherapy sources: the Amersham OncoSeed 6711 and the Imagyn IsoStar IS-12501. Results: GPUMCD was shown to yield dosimetric parameters similar to those found in the literature. It reproduces radial dose functions to within 1.25% for both sources in the 0.5< r <10 cm range. The 2D anisotropy function was found to be within 3% at r = 5 cm and within 4% at r = 1 cm. The dose rate constants obtained were within the range of other values reported in the literature.Conclusion: GPUMCD was shown to be able to reproduce various TG-43 parameters for two different low-energy brachytherapy sources found in the literature. The next step is to test GPUMCD as a fast clinical Monte Carlo brachytherapy dose calculations with multiple seeds and patient geometry, potentially providing

  5. Development of brachytherapy medium doserate

    International Nuclear Information System (INIS)

    Atang Susila; Ari Satmoko; Ahmad Rifai; Kristiyanti

    2010-01-01

    Brachytherapy has proven to be an effective treatment for different types of cancers and it become a common treatment modality in most radiotherapy clinics. PRPN has had experience in development of Low Dose Rate Brachytherapy for cervix cancer treatment. However the treatment process using LDR device needs 5 hours in time that the patient feel uncomfort. Therefore PRPN develops Medium Dose Rate Brachytherapy with radiation activity not more than 5 Currie. The project is divided into two stages. Purchasing of TPS software and TDS design are held in 2010, and the construction will be in 2011. (author)

  6. Dose determination in breast tumor in brachytherapy using Iridium-192

    International Nuclear Information System (INIS)

    Okuno, S.F.

    1984-01-01

    Thermoluminescent dosimetry studies in vivo and in vitro aiming to determing radiation dose in the breast tumor, in brachytherapy using Iridium-192 was done. The correlation between radiation doses in tumor and external surface of the breast was investigated for correcting the time interval of radiation source implantation. (author) [pt

  7. Pulsed dose rate brachytherapy – is it the right way?

    Directory of Open Access Journals (Sweden)

    Janusz Skowronek

    2010-10-01

    Full Text Available Pulsed dose rate (PDR-BT treatment is a brachytherapy modality that combines physical advantages of high-doserate (HDR-BT technology (isodose optimization, radiation safety with the radiobiological advantages of low-dose-rate (LDR-BT brachytherapy. Pulsed brachytherapy consists of using stronger radiation source than for LDR-BT and producing series of short exposures of 10 to 30 minutes in every hour to approximately the same total dose in the sameoverall time as with the LDR-BT. Modern afterloading equipment offers certain advantages over interstitial or intracavitaryinsertion of separate needles, tubes, seeds or wires. Isodose volumes in tissues can be created flexibly by a combinationof careful placement of the catheter and the adjustment of the dwell times of the computerized stepping source.Automatic removal of the radiation sources into a shielded safe eliminates radiation exposures to staff and visitors.Radiation exposure is also eliminated to the staff who formerly loaded and unloaded multiplicity of radioactive sources into the catheters, ovoids, tubes etc. This review based on summarized clinical investigations, analyses the feasibility and the background to introduce this brachytherapy technique and chosen clinical applications of PDR-BT.

  8. Biology of dose rate in brachytherapy

    International Nuclear Information System (INIS)

    Brenner, David J.

    1995-01-01

    Purpose: This course is designed for practitioners and beginners in brachytherapy. The aim is to review biological principles underlying brachytherapy, to understand why current treatment regimes are the way they are, and to discuss what the future may hold in store. Brachytherapy has a long history. It was suggested as long ago as 1903 by Alexander Graham Bell, and the optimal application of this technique has been a subject of debate ever since. 'Brachy' means 'short', and the essential features of conventional brachytherapy are: positioning of the source a short distance from, or in, the tumor, allowing good dose distributions; short overall treatment times, to counter tumor repopulation; low dose rate, enabling a good therapeutic advantage between tumor control and damage to late-responding tissue. The advantages of good dose distributions speak for themselves; in some situations, as we shall see, computer-based dose optimization can be used to improve them still further. The advantages of short overall times stem from the fact that accelerated repopulation of the tumor typically begins a few weeks after the start of a radiation treatment. If all the radiation can be crammed in before that time, the risks of tumor repopulation can be considerably reduced. In fact even external-beam radiotherapy is moving in this direction, with the use of highly accelerated protocols. The advantages of low dose rate stem from the differential response to fractionation of early- and late-responding tissues. Essentially, lowering the dose rate spares late-responding tissue more than it does early-responding tissue such as tumors. We shall also discuss some recent innovations in the context of the general principles that have been outlined. For example, High dose rate brachytherapy, particularly for the uterine cervix: Does it work? If so, when and why? Use of Ir-192 sources, with a half life of 70 days: Should corrections be made for changing biological effectiveness as the dose

  9. Multihelix rotating shield brachytherapy for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Dadkhah, Hossein [Department of Biomedical Engineering, University of Iowa, 1402 Seamans Center for the Engineering Arts and Sciences, Iowa City, Iowa 52242 (United States); Kim, Yusung; Flynn, Ryan T., E-mail: ryan-flynn@uiowa.edu [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States); Wu, Xiaodong [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 and Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center for the Engineering Arts and Sciences, Iowa City, Iowa 52242 (United States)

    2015-11-15

    Purpose: To present a novel brachytherapy technique, called multihelix rotating shield brachytherapy (H-RSBT), for the precise angular and linear positioning of a partial shield in a curved applicator. H-RSBT mechanically enables the dose delivery using only linear translational motion of the radiation source/shield combination. The previously proposed approach of serial rotating shield brachytherapy (S-RSBT), in which the partial shield is rotated to several angular positions at each source dwell position [W. Yang et al., “Rotating-shield brachytherapy for cervical cancer,” Phys. Med. Biol. 58, 3931–3941 (2013)], is mechanically challenging to implement in a curved applicator, and H-RSBT is proposed as a feasible solution. Methods: A Henschke-type applicator, designed for an electronic brachytherapy source (Xoft Axxent™) and a 0.5 mm thick tungsten partial shield with 180° or 45° azimuthal emission angles and 116° asymmetric zenith angle, is proposed. The interior wall of the applicator contains six evenly spaced helical keyways that rigidly define the emission direction of the partial radiation shield as a function of depth in the applicator. The shield contains three uniformly distributed protruding keys on its exterior wall and is attached to the source such that it rotates freely, thus longitudinal translational motion of the source is transferred to rotational motion of the shield. S-RSBT and H-RSBT treatment plans with 180° and 45° azimuthal emission angles were generated for five cervical cancer patients with a diverse range of high-risk target volume (HR-CTV) shapes and applicator positions. For each patient, the total number of emission angles was held nearly constant for S-RSBT and H-RSBT by using dwell positions separated by 5 and 1.7 mm, respectively, and emission directions separated by 22.5° and 60°, respectively. Treatment delivery time and tumor coverage (D{sub 90} of HR-CTV) were the two metrics used as the basis for evaluation and

  10. Mapping intravascular ultrasound controversies in interventional cardiology practice.

    Directory of Open Access Journals (Sweden)

    David Maresca

    Full Text Available Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound innovation has been relatively limited. Intravascular ultrasound remains a niche technology; its clinical practice did not vastly expand, except in Japan, where intravascular ultrasound is an appraised tool for guiding percutaneous coronary interventions. In this qualitative research study, we follow scholarship on the sociology of innovation in exploring both the current adoption practices and perspectives on the future of intravascular ultrasound. We conducted a survey of biomedical experts with experience in the technology, the practice, and the commercialization of intravascular ultrasound. The collected information enabled us to map intravascular ultrasound controversies as well as to outline the dynamics of the international network of experts that generates intravascular ultrasound innovations and uses intravascular ultrasound technologies. While the technology is praised for its capacity to measure coronary atherosclerotic plaque morphology and is steadily used in clinical research, the lack of demonstrated benefits of intravascular ultrasound guided coronary interventions emerges as the strongest factor that prevents its expansion. Furthermore, most of the controversies identified were external to intravascular ultrasound technology itself, meaning that decision making at the industrial, financial and regulatory levels are likely to determine the future of intravascular ultrasound. In light of opinions from the responding experts', a wider adoption of intravascular ultrasound as a stand-alone imaging modality seems rather uncertain, but the appeal for this technology may be renewed by improving image quality and through combination with

  11. Use of Monte Carlo Methods in brachytherapy; Uso del metodo de Monte Carlo en braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Granero Cabanero, D.

    2015-07-01

    The Monte Carlo method has become a fundamental tool for brachytherapy dosimetry mainly because no difficulties associated with experimental dosimetry. In brachytherapy the main handicap of experimental dosimetry is the high dose gradient near the present sources making small uncertainties in the positioning of the detectors lead to large uncertainties in the dose. This presentation will review mainly the procedure for calculating dose distributions around a fountain using the Monte Carlo method showing the difficulties inherent in these calculations. In addition we will briefly review other applications of the method of Monte Carlo in brachytherapy dosimetry, as its use in advanced calculation algorithms, calculating barriers or obtaining dose applicators around. (Author)

  12. Verification of the calculation program for brachytherapy planning system of high dose rate (PLATO)

    International Nuclear Information System (INIS)

    Almansa, J.; Alaman, C.; Perez-Alija, J.; Herrero, C.; Real, R. del; Ososrio, J. L.

    2011-01-01

    In our treatments are performed brachytherapy high dose rate since 2007. The procedures performed include gynecological intracavitary treatment and interstitial. The treatments are performed with a source of Ir-192 activity between 5 and 10 Ci such that small variations in treatment times can cause damage to the patient. In addition the Royal Decree 1566/1998 on Quality Criteria in radiotherapy establishes the need to verify the monitor units or treatment time in radiotherapy and brachytherapy. All this justifies the existence of a redundant system for brachytherapy dose calculation that can reveal any abnormality is present.

  13. Brachytherapy in childhood rhabdomyosarcoma treatment

    International Nuclear Information System (INIS)

    Novaes, Paulo Eduardo Ribeiro dos Santos

    1995-01-01

    A retrospective study of 21 children with rhabdomyosarcoma treated by brachytherapy to the primary site of the tumor at the Radiotherapy Department of the A.C.Camargo Hospital between january/1980 to june/1993 was undertaken. The main objectives were to comprove the utility of brachytherapy in childhood rhabdomyosarcoma, to evaluate the local control and survival, in association with chemotherapy, to analyze the late effects of the treatment and to determinate the preferential technique to each clinical situation. All patients received brachytherapy to the tumor site. The radioactive isotopes employed were Gold 198 , Cesium 137 and Iridium 192 . The brachytherapy techniques depended on the tumor site, period of treatment, availability of the radioactive material and stage of the disease. Patients treated exclusively by brachytherapy received 40 Gy to 60 Gy. When brachytherapy was associated with external radiotherapy the dose ranged from 20 Gy to 40 Gy. Local control was achieved in 18 of 20 patients (90%). The global survival and local control survival rates were 61.9% (13/21 patients) and 72,2% (13/18 patients) respectively. (author)

  14. Intravascular photoacoustic imaging of human coronary atherosclerosis

    Science.gov (United States)

    Jansen, Krista; van der Steen, Antonius F. W.; Springeling, Geert; van Beusekom, Heleen M. M.; Oosterhuis, J. Wolter; van Soest, Gijs

    2011-03-01

    We demonstrate intravascular photoacoustic imaging of human coronary atherosclerotic plaque. We specifically imaged lipid content, a key factor in vulnerable plaques that may lead to myocardial infarction. An integrated intravascular photoacoustics (IVPA) and ultrasound (IVUS) catheter with an outer diameter of 1.25 mm was developed. The catheter comprises an angle-polished optical fiber adjacent to a 30 MHz single-element transducer. The ultrasonic transducer was optically isolated to eliminate artifacts in the PA image. We performed measurements on a cylindrical vessel phantom and isolated point targets to demonstrate its imaging performance. Axial and lateral point spread function widths were 110 μm and 550 μm, respectively, for PA and 89 μm and 420 μm for US. We imaged two fresh human coronary arteries, showing different stages of disease, ex vivo. Specific photoacoustic imaging of lipid content, is achieved by spectroscopic imaging at different wavelengths between 1180 and 1230 nm.

  15. Local anesthesia for prostate brachytherapy

    International Nuclear Information System (INIS)

    Wallner, Kent; Simpson, Colleen; Roof, James; Arthurs, Sandy; Korssjoen, Tammy; Sutlief, Steven

    1999-01-01

    Purpose: To demonstrate the technique and feasibility of prostate brachytherapy performed with local anesthesia only. Methods and Materials: A 5 by 5 cm patch of perineal skin and subcutaneous tissue is anesthetized by local infiltration of 10 cc of 1% lidocaine with epinephrine, using a 25-gauge 5/8-inch needle. Immediately following injection into the subcutaneous tissues, the deeper tissues, including the pelvic floor and prostate apex, are anesthetized by injecting 15 cc lidocaine solution with approximately 8 passes of a 20-gauge 1.0-inch needle. Following subcutaneous and peri-apical lidocaine injections, the patient is brought to the simulator suite and placed in leg stirrups. The transrectal ultrasound (TRUS) probe is positioned to reproduce the planning images and a 3.5- or 6.0-inch, 22-gauge spinal needle is inserted into the peripheral planned needle tracks, monitored by TRUS. When the tips of the needles reach the prostatic base, about 1 cc of lidocaine solution is injected in the intraprostatic track, as the needle is slowly withdrawn, for a total volume of 15 cc. The implants are done with a Mick Applicator, inserting and loading groups of two to four needles, so that a maximum of only about four needles are in the patient at any one time. During the implant procedure, an additional 1 cc of lidocaine solution is injected into one or more needle tracks if the patient experiences substantial discomfort. The total dose of lidocaine is generally limited to 500 mg (50 ml of 1% solution). Results: To date, we have implanted approximately 50 patients in our simulator suite, using local anesthesia. Patients' heart rate and diastolic blood pressure usually showed moderate changes, consistent with some discomfort. The time from first subcutaneous injection and completion of the source insertion ranged from 35 to 90 minutes. Serum lidocaine levels were below or at the low range of therapeutic. There has been only one instance of acute urinary retention in the

  16. INTRAVASCULAR ENDOTHELIOMA (ENDOTHELIOMA IN SITU, SYSTEMIC ENDOTHELIOMATOSIS).

    Science.gov (United States)

    HABER, H; HARRIS-JONES, J N; WELLS, A L

    1964-11-01

    A woman aged 48 years was found to be suffering from intravascular endothelioma. The initial clinical presentation was the presence of red, painless swellings in the skin of the lower limbs. The other clinical features, and the histological changes in skin biopsies, are described and compared with those in the two previously reported patients. It is suggested that the condition is analogous to the pre-invasive carcinomatous states.

  17. Developing a Verification and Training Phantom for Gynecological Brachytherapy System

    Directory of Open Access Journals (Sweden)

    Mahbobeh Nazarnejad

    2012-03-01

    Full Text Available Introduction Dosimetric accuracy is a major issue in the quality assurance (QA program for treatment planning systems (TPS. An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT of gynecological (Gyn cancer it is usual to insert a combination of tandem and ovoid applicators with a complicated geometry which makes their dosimetry verification difficult and important. Therefore, evaluation and verification of dose distribution is necessary for accurate dose delivery to the patients. Materials and Methods The solid phantom was made from Perspex slabs as a tool for intracavitary brachytherapy dosimetric QA. Film dosimetry (EDR2 was done for a combination of ovoid and tandem applicators introduced by Flexitron brachytherapy system. Treatment planning was also done with Flexiplan 3D-TPS to irradiate films sandwiched between phantom slabs. Isodose curves obtained from treatment planning system and the films were compared with each other in 2D and 3D manners. Results The brachytherapy solid phantom was constructed with slabs. It was possible to insert tandems and ovoids loaded with radioactive source of Ir-192 subsequently. Relative error was 3-8.6% and average relative error was 5.08% in comparison with the films and TPS isodose curves. Conclusion Our results showed that the difference between TPS and the measurements is well within the acceptable boundaries and below the action level according to AAPM TG.45. Our findings showed that this phantom after minor corrections can be used as a method of choice for inter-comparison analysis of TPS and to fill the existing gap for accurate QA program in intracavitary brachytherapy. The constructed phantom also showed that it can be a valuable tool for verification of accurate dose delivery to the patients as well as training for brachytherapy residents and physics students.

  18. Radiotherapy and brachytherapy

    International Nuclear Information System (INIS)

    2007-02-01

    This presentation first defines the radiotherapy and brachytherapy techniques, indicates the used ionizing radiations (electromagnetic and particles), describes the mechanisms and processes of action of ionizing radiations: they can be physical by photon-matter interactions (Compton effect and photoelectric effect) or due to electron-matter interactions (excitation, ionization), physical-chemical by direct or indirect action (DNA damage), cellular (mitotic or apoptotic death), tissue (sane and tumorous tissues and differential effect). It discusses the biological efficiency of these treatments which depends on different parameters: intrinsic radio-sensitivity, time (session fractioning and organisation in time), oxygen, radiation quality, cellular cycle, dose rate, temperature. It presents the different types of radiotherapy: external radiotherapy (general sequence, delineation, dosimetry, protection of critical organs, treatment session, quality control, monitoring consultation) and briefly presents some specific techniques (total body irradiation, total cutaneous electron therapy, pre-operation radiotherapy, radio-surgery, hadron-therapy). It proposes an overview of the main indications for this treatment: brain tumours, upper aero digestive tract tumours, bronchial tumours, oesophagus, stomach and pancreas tumours, breast tumours, cervix cancer, rectum tumour, and so on, and indicates the possible associated treatments. The next part addresses brachytherapy. It presents the principles and comments the differences with radiotherapy. It indicates the used radio-elements (Caesium 137, Iridium 192, Iodine 125), describes the implementation techniques (plastic tubes, use of iodine 125, intracavitary and endo-luminal radiation therapy). It proposes an overview of the different treated tumours (skin, breast, prostates, bronchial, oesophagus, ENT) and indicates possible early and late secondary effects for different organs

  19. Radiological protection on interstitial brachytherapy and dose determination and exposure rate of an Ir-192 source through the MCNP-4B; Proteccion radiologica en braquiterapia intersticial y determinacion de la dosis y tasa de exposicion de una fuente de Ir-192 mediante el MCNP-4B

    Energy Technology Data Exchange (ETDEWEB)

    Morales L, M.E. [INEN, Av. Angamos Este 2520- Surquillo, Lima (Peru)

    2006-07-01

    The present work was carried out in the Neurological Sciences Institute having as objective to determine the dose and the rate of exhibition of the sources of Iridium 192, Iodine 125 and Palladium 103; which are used to carry out implant in the Interstitial Brachytherapy according to the TG43. For it we carry out a theoretical calculation, its are defined in the enter file: the geometry, materials of the problem and the radiation source, etc; in the MCNP-4B Monte Carlo code, considering a punctual source and for the dose determination we simulate thermoluminescent dosemeters (TLD): at 5 cm, 50 cm, 100 cm and 200 cm of the source. Our purpose is to analyze the radioprotection measures that should take into account in this Institute in which are carried out brain biopsies using a Micro mar stereotactic mark, and in a near future with the collaboration of a doctor and a cuban physique seeks to be carried out the Interstitial Brachytherapy technique with sources of Ir-192 for patient with tumors like glioblastoma, astrocytoma, etc. (Author)

  20. The hazy dawn of brachytherapy

    International Nuclear Information System (INIS)

    Dutreix, J.; Tubiana, M.; Pierquin, B.

    1998-01-01

    The discovery of radium by Pierre and Marie Curie in December 1898 opened a new era in science and within a few years provided medicine with a new means of tumor treatment. Their personal contribution to the start and early development of clinical applications should not be overlooked. The Curies did not limit their support to providing radium sources to medical pioneers but took a deep interest in the horizons of radiumtherapy. Pierre was one of the first to search for and demonstrate a biological effect of radium radiation. He investigated the radioactivity of the waters of hydrotherapeutic resorts. Marie took care of the measurement of the medical sources personally, convinced that the result of the treatment depends on the precise knowledge of the amount of radium applied. Her perseverance resulted in the establishment of the Institut du Radium (1909) in which, besides the physico-chemical laboratory, a biological department was set up. The latter became the Fondation Curie (1920), a leading medical center of treatment and training, with an integrated team of physicists, radiobiologists and clinicians led by Regaud. One hundred years after the discovery of radium, patients benefit today from the extensive clinical experience that has been collected over the years and from sophisticated developments in application techniques, dosimetry and quality assurance; the professional risk has been precisely assessed and the improvements in material and procedure have enabled the medical personnel to work in hazard-free conditions. This outcome results from the continuous progress that the pioneers gave impulse to. This paper intends to recall their efforts and achievements, as well as the difficulties and the problems they encountered during the first 2 decades when the sturdy foundations of brachytherapy were built. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  1. Erectile function after prostate brachytherapy

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Wallner, Kent E.; Galbreath, Robert W.; Anderson, Richard L.; Kurko, Brian S.; Lief, Jonathan H.; Allen, Zachariah A.

    2005-01-01

    Purpose: To evaluate erectile function after permanent prostate brachytherapy using a validated patient-administered questionnaire and to determine the effect of multiple clinical, treatment, and dosimetric parameters on penile erectile function. Methods and materials: A total of 226 patients with preimplant erectile function determined by the International Index of Erectile Function (IIEF) questionnaire underwent permanent prostate brachytherapy in two prospective randomized trials between February 2001 and January 2003 for clinical Stage T1c-T2c (2002 American Joint Committee on Cancer) prostate cancer. Of the 226 patients, 132 were potent before treatment and, of those, 128 (97%) completed and returned the IIEF questionnaire after brachytherapy. The median follow-up was 29.1 months. Potency was defined as an IIEF score of ≥13. The clinical, treatment, and dosimetric parameters evaluated included patient age; preimplant IIEF score; clinical T stage; pretreatment prostate-specific antigen level; Gleason score; elapsed time after implantation; preimplant nocturnal erections; body mass index; presence of hypertension or diabetes mellitus; tobacco consumption; the volume of the prostate gland receiving 100%, 150%, and 200% of the prescribed dose (V 100/150/200 ); the dose delivered to 90% of the prostate gland (D 90 ); androgen deprivation therapy; supplemental external beam radiotherapy (EBRT); isotope; prostate volume; planning volume; and radiation dose to the proximal penis. Results: The 3-year actuarial rate of potency preservation was 50.5%. For patients who maintained adequate posttreatment erectile function, the preimplant IIEF score was 29, and in patients with brachytherapy-related ED, the preimplant IIEF score was 25. The median time to the onset of ED was 5.4 months. After brachytherapy, the median IIEF score was 20 in potent patients and 3 in impotent patients. On univariate analysis, the preimplant IIEF score, patient age, presence of nocturnal

  2. Hypothesis: Disseminated Intravascular Inflammation as the Inflammatory Counterpart to Disseminated Intravascular Coagulation

    Science.gov (United States)

    Bull, Brian S.; Bull, Maureen H.

    1994-08-01

    We have identified a leukocyte activation syndrome that is occasionally associated with the transfusion of intraoperatively recovered erythrocytes. This syndrome appears to result from intravascular damage caused by leukocytes activated during the erythrocyte salvage process. We hypothesize that this syndrome is part of a larger disease grouping: disseminated intravascular inflammation (DII). DII is the analog of the coagulation disorder disseminated intravascular coagulation. In disseminated intravascular coagulation, the organ damage results from uncontrolled activation of the clotting pathway; in DII the damage is caused by leukocytes that have become activated by direct contact with bacteria or in rare instances-such as erythrocyte salvage-in the absence of bacteria and bacterial products. Recent studies of the hazards associated with intraoperative blood salvage indicate that activation of leukocytes can be achieved by exposure to activated platelets alone. If such activated leukocytes are reinfused along with the washed erythrocytes, widespread organ damage may result. The lung is the organ most severely affected by activated leukocytes. Adult respiratory distress syndrome is one outcome. It is likely that DII is a presently unrecognized pathophysiological process that complicates a variety of primary disease states and increases their lethality.

  3. Experiences with alanine dosimetry in afterloading brachytherapy

    International Nuclear Information System (INIS)

    Eberhardt, H.-J.; Gohs, U.

    1996-01-01

    At the present, the most commonly used dosimetry for radiotherapy applications are ionisation chambers and thermoluminescent dosimeters (TLD). However, there are some undesirable characteristics of these dosimetry systems, such as large detection volume (ionisation chamber) as well as fading of the radiation induced signal with time and destructive readout (TLG). The present study is an investigation into the use of the alanine/ESR dosimetry in fractionated afterloading brachytherapy during the whole radiotherapy course. There are some qualities which make alanine dosimetry attractive. These are the linear energy response, low fading under standard conditions, and the nondestructive readout. Thus the alanine dosimetry makes possible cumulative dose measurements during the radiotherapy course and an archival storage. By ionizing radiation (gamma, e, n, p, charged particles) free radicals (unpaired electrons) are produced in the amino acid alanine. The continuous wave electron spin resonance (ESR) spectroscopy is used to determine the number of free radicals, which is proportional to the absorbed dose and the alanine content of the dosimeter. The ESR measurements were made at room temperature using a Bruker EPR analyzer EMS-104. The dosimeters used in the test are alanine pellets (23.72 mg weight, 4.9 mm diameter, 1 mm height) as well as flexible alanine film dosimeters (thickness about 500 μm). The dosimeters consist of a blend of L-alpha-alanine and a binder. The alanine content of the pellets and the film dosimeters is about 88 % and 50 % by weight, respectively. The dosimeters for the calculation of the dose-effect-relationship were irradiated at the Physical-Technical Bundesanstalt in Braunschweig by a standard 60Co source. The maximum deviation from the calculated linear function is about 0.12 Gy in the dose range up to 80 Gy. The goal of medical applications was the superficial dose measurement in afterloading brachytherapy during the radiotherapy course in

  4. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    Science.gov (United States)

    Yamashita, Shuji; Narushima, Mitsunaga; Koshima, Isao; Miyamoto, Shimpei

    2017-01-01

    Background: Although supermicrosurgical anastomosis is a widely known reconstructive microsurgical technique, it is difficult to perform. To expand the clinical use of supermicrosurgery, we used hemi-intravascular stenting (hemi-IVaS), which is performed by inserting an intravascular stent into one side of the vessel. We conducted lymphaticovenular anastomosis, free perforator flap transfer, and fingertip replantation with supermicrosurgical anastomosis using hemi-IVaS technique and examined its usefulness. Methods: Between January 2013 and February 2015, 11 anastomoses in 11 cases of lymphaticovenular anastomosis for lymphedema patients, 14 anastomoses in 7 cases of free perforator flap transfer with supermicrosurgical perforator-to-perforator anastomosis, and 9 anastomoses in 5 cases of fingertip replantation were performed using hemi-IVaS. Time required for anastomosis and complications were examined. Flap survival rate was also examined in free perforator flap transfer cases and fingertip replantation cases. Results: In all cases, anastomoses were performed without complications such as inadvertent catching of the back wall of the vessel during the procedure or the need for reanastomoses. The average time required to complete the anastomosis was 16.4 ± 3.20 minutes using the hemi IVaS technique. All flaps survived in the supermicrosurgical perforator-to-perforator anastomosis as well as fingertip replantation cases. Conclusions: Hemi-IVaS could be a useful alternative to conventional intravascular stenting techniques and is also effective for supermicrosurgical perforator-to-perforator anastomosis. Further studies are needed to improve the success rate and to explore its other possible utilizations in supermicrosurgery. PMID:29263952

  5. Air density dependence of the response of the PTW SourceCheck 4pi ionization chamber for 125I brachytherapy seeds.

    Science.gov (United States)

    Torres Del Río, J; Tornero-López, A M; Guirado, D; Pérez-Calatayud, J; Lallena, A M

    2017-06-01

    To analyze the air density dependence of the response of the new SourceCheck 4pi ionization chamber, manufactured by PTW. The air density dependence of three different SourceCheck 4pi chambers was studied by measuring 125 I sources. Measurements were taken by varying the pressure from 746.6 to 986.6hPa in a pressure chamber. Three different HDR 1000 Plus ionization chambers were also analyzed under similar conditions. A linear and a potential-like function of the air density were fitted to experimental data and their achievement in describing them was analyzed. SourceCheck 4pi chamber response showed a residual dependence on the air density once the standard pressure and temperature factor was applied. The chamber response was overestimated when the air density was below that under normal atmospheric conditions. A similar dependence was found for the HDR 1000 Plus chambers analyzed. A linear function of the air density permitted a very good description of this residual dependence, better than with a potential function. No significant variability between the different specimens of the same chamber model studied was found. The effect of overestimation observed in the chamber responses once they are corrected for the standard pressure and temperature may represent a non-negligible ∼4% overestimation in high altitude cities as ours (700m AMSL). This overestimation behaves linearly with the air density in all cases analyzed. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  6. Intravascular haemolysis: a potential missed diagnosis.

    Science.gov (United States)

    Sinclair, David; Briston, Philip; Rutland, Emma

    2002-01-01

    Raised serum bilirubin is a common finding as part of a routine "liver function test" profile. This case describes a patient with a raised serum bilirubin that was eventually found to be caused by intravascular haemolysis. The tests that confirmed the cause were instigated by clinical biochemistry staff but not before the patient had undergone unnecessary invasive procedures and had the diagnosis delayed by some time. The case is a reminder to biochemistry and haematology laboratories and clinical staff to investigate the possibility of haemolysis as well as hepatitis and Gilbert's disease as a cause of an isolated raised bilirubin.

  7. Mapping Intravascular Ultrasound Controversies in Interventional Cardiology Practice

    NARCIS (Netherlands)

    Maresca, D.; Adams, S.; Maresca, B.; Van der Steen, A.F.W.

    2014-01-01

    Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound

  8. Mapping intravascular ultrasound controversies in interventional cardiology practice

    NARCIS (Netherlands)

    Maresca, David; Adams, Samantha; Maresca, Bruno; van der Steen, Antonius F W

    2014-01-01

    Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound

  9. Evaluation of resins for use in brachytherapy

    International Nuclear Information System (INIS)

    Carvalho, Luiz Claudio F.M. Garcia; Ferraz, Wilmar Barbosa; Chrcanovic, Bruno Ramos; Santos, Ana Maria M.

    2011-01-01

    Brachytherapy is an advanced cancer treatment where radioactive seeds or sources are placed near or directly into the tumor thus reducing the radiation exposure in the surrounding healthy tissues. Prostate cancer can be treated with interstitial brachytherapy in initial stage of the disease in which tiny radioactive seeds with cylindrical geometry are used. Several kinds of seeds have been developed in order to obtain a better dose distribution around them and with a lower cost manufacturing. These seeds consist of an encapsulation, a radionuclide carrier, and X-ray marker. Among the materials that have potential for innovation in the construction of seeds, biocompatible resins appear as an important option. In this paper, we present some characterization results with Fourier transform infrared spectroscopic (FTIR) and ultraviolet-visible spectroscopy (UV-vis) performed on two types of resins in which curing temperatures for each one were varied as also the results of coatings with these resins under titanium substrates. Interactions of these resins in contact with the simulated body fluid were evaluated by atomic force microscopy, scanning electron microscopy, and energy dispersive X-ray spectroscopy. (author)

  10. Evaluation of resins for use in brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Luiz Claudio F.M. Garcia; Ferraz, Wilmar Barbosa; Chrcanovic, Bruno Ramos; Santos, Ana Maria M., E-mail: ferrazw@cdtn.b, E-mail: amms@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Brachytherapy is an advanced cancer treatment where radioactive seeds or sources are placed near or directly into the tumor thus reducing the radiation exposure in the surrounding healthy tissues. Prostate cancer can be treated with interstitial brachytherapy in initial stage of the disease in which tiny radioactive seeds with cylindrical geometry are used. Several kinds of seeds have been developed in order to obtain a better dose distribution around them and with a lower cost manufacturing. These seeds consist of an encapsulation, a radionuclide carrier, and X-ray marker. Among the materials that have potential for innovation in the construction of seeds, biocompatible resins appear as an important option. In this paper, we present some characterization results with Fourier transform infrared spectroscopic (FTIR) and ultraviolet-visible spectroscopy (UV-vis) performed on two types of resins in which curing temperatures for each one were varied as also the results of coatings with these resins under titanium substrates. Interactions of these resins in contact with the simulated body fluid were evaluated by atomic force microscopy, scanning electron microscopy, and energy dispersive X-ray spectroscopy. (author)

  11. Perioperative neutron brachytherapy with californium-252.

    Science.gov (United States)

    Vtyurin, B M; Medvedev, V S; Ivanov, V N; Anikin, V A; Ivanova, L F

    1992-01-01

    Between 1973 and 1988, 495 patients were treated with Cf-252 neutron brachytherapy. Cf-252 neutron therapy sources developed in the USSR has been used in the trial. A numerical reconstruction method for localization of Cf-252 cell coordinates by projections on orthogonal radiographs has been designed and used for treatment planning. Eight (1.6%) patients with recurrent and persistent head and neck tumors and ages from 32 to 48 years (mean age 43 years) were treated with Cf-252 perioperative neutron brachytherapy. There were three patients with oral cavity, one with oropharynx, three with parotid gland cancers, and one with a skin tumor. The dose rate ranged fro 3.2 cGy/h to 11.1 cG/h, the minimal peripheral dose ranged from 3 Gy to 8 Gy. Initial local control was achieved in all patients. Local recurrence developed in two cases. Three patients died in first year after therapy. Three patients died during the second year. Two patients are long term cures, one patient more than nine years and one eight years, that is 25% of the treated patients.

  12. Effects of Hypoxia on Erythrocyte Membrane Properties—Implications for Intravascular Hemolysis and Purinergic Control of Blood Flow

    Directory of Open Access Journals (Sweden)

    Ryszard Grygorczyk

    2017-12-01

    Full Text Available Intravascular hemolysis occurs in hereditary, acquired, and iatrogenic hemolytic conditions but it could be also a normal physiological process contributing to intercellular signaling. New evidence suggests that intravascular hemolysis and the associated release of adenosine triphosphate (ATP may be an important mechanism for in vivo local purinergic signaling and blood flow regulation during exercise and hypoxia. However, the mechanisms that modulate hypoxia-induced RBC membrane fragility remain unclear. Here, we provide an overview of the role of RBC ATP release in the regulation of vascular tone and prevailing assumptions on the putative release mechanisms. We show importance of intravascular hemolysis as a source of ATP for local purinergic regulation of blood flow and discuss processes that regulate membrane propensity to rupture under stress and hypoxia.

  13. Role of informed consent for intravascular contrast media

    International Nuclear Information System (INIS)

    Hopper, K.D.; Tyler, H.N. Jr.

    1988-01-01

    To evaluate the usefulness of different degrees of informed consent for intravascular contrast media, the authors divided 100 patients into four groups: (1) informed consent with no information on intravascular contrast media, (2) simple written informed consent that detailed common risks, (3) detailed written informed consent that detailed all known risks, and (4) MD informed consent, during which a radiologist discussed all known risks of intravascular contrast media. Physician counseling time for group 4 averaged 11.4 minutes. On a postprocedure test about the common complications and risk factors of intravascular contrast media, the average scores were: group 1, 38.4%; group 2, 68.2%; group 3, 63.2%; and group 4, 69.8%. There was no statistical difference between groups 2-4 on the postprocedure test. If informed consent is to be used prior to intravascular contrast media administration, a simple written consent detailing the common risks and risk factors appears to be the best method

  14. Recommendations of the EVA GEC ESTRO Working Group: prescribing, recording, and reporting in endovascular brachytherapy. Quality assurance, equipment, personnel and education

    International Nuclear Information System (INIS)

    Poetter, Richard; Limbergen, Erik van; Dries, Wim; Popowski, Youri; Coen, Veronique; Fellner, Claudia; Georg, Dietmar; Kirisits, Christian; Levendag, Peter; Marijnissen, Hans; Marsiglia, Hugo; Mazeron, Jean-Jaques; Pokrajac, Boris; Scalliet, Pierre; Tamburini, Vittorio

    2001-01-01

    Endovascular brachytherapy is a new, rapidly growing field of interest in radiotherapy for the prevention of neointimal hyperplasia after angioplasty in both coronary and peripheral arteries. Many physics aspects of these treatments have already been addressed in the report of the American Association of Physicists in Medicine task group on 'Intravascular brachytherapy', but up to now there are no generally accepted recommendations for recording and reporting radiation doses and volumes. The terminology to be used by all individuals involved in such treatments (radiation oncologists, physicists, and interventionalists) is not clearly defined. The Endovascular Groupe Europeen de Curietherapie/European Society for Therapeutic Radiology and Oncology Working Group in this document presents recommendations for a common language for general use in endovascular brachytherapy. This proposal addresses general terms and concepts for target and dose specification as well as detailed recommendations for dose prescription, recording and reporting in endovascular brachytherapy for both peripheral and coronary arteries. Additionally, quality assurance and radiation safety aspects are briefly addressed, as are aspects related to equipment, personnel, and training and education related to endovascular brachytherapy

  15. Discrimination of intravascular lumen and dissections in single intravascular ultrasound images using subtraction, conventional averaging and saline flush

    NARCIS (Netherlands)

    G. Pasterkamp (Gerard); M.S. van der Heiden (M.); M.J. Post (Mark); C. Borst (Cornelius); E.J. Gussenhoven (Elma); H. Pieterman; H. van Urk (Hero); N. Bom (Klaas)

    1995-01-01

    textabstractWith current 30-MHz intravascular ultrasound systems, flowing blood may cause considerable backscatter which in real-time images is characterized by dynamic speckle. However, in a single intravascular ultrasound image (still-frame) the discrimination between arterial lumen and wall may

  16. Cervical cancer. Application of MR imaging in brachytherapy

    International Nuclear Information System (INIS)

    Ebe, Kazuyu; Matsunaga, Naofumi

    1996-01-01

    For the purpose of application of MRI in arrangement of brachytherapy of cervical cancer, a method was proposed to see the radiation doses in surrounding tissues by superimposing the dose distribution pattern of the radiation source on the MR image. The applicator for the source was filled with water to get its T2-weighted image and was inserted in the patients. The MRI apparatus was Siemens Magnetom Vision (1.5T) with phased array coil. T2-weighted sagittal and coronary images were taken by turbospin echo and HASTE methods. The section thickness was 5 mm. The dose distribution pattern was superimposed on the frontal and lateral images by Siemens Mevaplan to see the doses in surrounding tissues. In 4 patients, it was possible to estimate the radiation dose in the posterior wall of bladder, anterior wall of rectum and urinary duct. The method is promising for arranging brachytherapy of cervical cancer. (K.H.)

  17. Ultrasonography-guided cobalt-60 brachytherapy for malignant glioma

    International Nuclear Information System (INIS)

    Sakai, Noboru; Takenaka, Katsunobu; Ueda, Tatsuya

    1989-01-01

    Brachytherapy with cobalt-60 source is reported. In this method it is characterized that the source is inserted interstitially with remote control system by after-loading method via outer catheter (using tandem tube), which was established in the center of residual tumor, using ultrasonography guide with trepanation, or intraoperatively put within the dead space after tumor resection. Six cases of deep-seated and recurrent malignant glioma, were treated with this method. A total dose of 20 to 45 Gy (10 to 15 Gy/day for 2 to 3 days) was delivered to the target. Additionally conventional external irradiation was followed. The effect of cobalt-60 brachytherapy on such tumors were favorable especially for well-circumscribed glioma less than 3 cm on CT scan. (author)

  18. Dosimetry Studies of a Special Applicator for Post Hysterectomy Brachytherapy

    International Nuclear Information System (INIS)

    Schwob, N.; Shani, G.; Orion, I.

    2004-01-01

    The treatment of uterine cancer can include surgery, external beam radiotherapy and brachytherapy. The brachytherapy of the vagina stump is usually performed by inserting a radioactive source into a one channel cylindrical applicator. The resulting isodoses map from such treatment contains elliptical lines, while the target region is quite flat. A new eight-channel applicator has been developed at Hadassah University Hospital in order to obtain a flatter isodoses map (Figure 1). An 192 Ir source is loaded from the Nucletron microSelectron PDR afterloading system, step by step, at pre-selected dwell points in every channel, with pre-calculated irradiation dwell time. The particular irradiation program for every patient, the dose distribution and the isodoses were calculated using a treatment planning system (TPS) and the plan had been optimized [1]. In routine work, this is the only practical way to find the dose distribution obtained during the treatment

  19. Brachytherapy dosimeter with silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Moutinho, L.M., E-mail: moutinho@ua.pt [i3N, Physics Department, University of Aveiro (Portugal); Castro, I.F.C. [i3N, Physics Department, University of Aveiro (Portugal); Peralta, L. [Faculdade de Ciências da Universidade de Lisboa (Portugal); Laboratório de Instrumentação e Física Experimental de Partículas (LIP), Lisboa (Portugal); Abreu, M.C. [Laboratório de Instrumentação e Física Experimental de Partículas (LIP), Lisboa (Portugal); Veloso, J.F.C.A. [i3N, Physics Department, University of Aveiro (Portugal)

    2015-07-01

    In-vivo and in-situ measurement of the radiation dose administered during brachytherapy faces several technical challenges, requiring a very compact, tissue-equivalent, linear and highly sensitive dosimeter, particularly in low-dose rate brachytherapy procedures, which use radioactive seeds with low energy and low dose deposition rate. In this work we present a scintillating optical fiber dosimeter composed of a flexible sensitive probe and a dedicated electronic readout system based on silicon photomultiplier photodetection, capable of operating both in pulse and current modes. The performance of the scintillating fiber optic dosimeter was evaluated in low energy regimes, using an X-ray tube operating at voltages of 40–50 kV and currents below 1 mA, to assess minimum dose response of the scintillating fiber. The dosimeter shows a linear response with dose and is capable of detecting mGy dose variations like an ionization chamber. Besides fulfilling all the requirements for a dosimeter in brachytherapy, the high sensitivity of this device makes it a suitable candidate for application in low-dose rate brachytherapy. According to Peralta and Rego [1], the BCF-10 and BCF-60 scintillating optical fibers used in dosimetry exhibit high variations in their sensitivity for photon beams in the 25–100 kVp energy range. Energy linearity for energies below 50 keV needs to be further investigated, using monochromatic X-ray photons.

  20. Brachytherapy of choroidal melanomas

    International Nuclear Information System (INIS)

    Brady, L.W.; Hernandez, J.C.

    1992-01-01

    In a compilation of nine reported series consisting of 2,024 enucleations, the five- and ten-year survivals following surgery were 63% and 43%, respectively. The 25-year survival has been reported to be 40%. In 1974 at Wills Eye Hospital and Hahnemann University, the cobalt-60 plaques technique was introduced. During the following years, other radioactive isotopes were introduced including irridium-192, iodine-125, ruthenium-106/rhodium-106 and more recently palladium-103. At the present time, iodine-125 is the most widely used radionuclide. Until now, 302 patients treated with plaque brachytherapy showed an actuarial survival of 77% and 67.8% at five and eight years, respectively. There was no significant survival difference when compared with a similar group of patients undergoing enucleation. Other retrospective studies show similar excellent results. In spite of these convincing results, the decision making process in management melanoma remains unsettled primarily due to the absence of prospective randomized trials. Because of this, the Collaborative Ocular Melanoma Study was initiated. From the standpoint of toxicity, the data are available on ocular radiation toxicity. In an analysis of 77 patients from the Wills Eye Hospital with pretreatment visual acuities of 20/25 or better, it was noted that 90% of patients who had received less than 500 Gy to the fovea retained visual acuity of 20/200 or better while only 52% of patients receiving more than 5,000 Gy to the fovea had vision of 20/200 or better. A serious late effect of radioactivity plaque treatment is scleral necrosis which may require repair or enucleation even in the absence of tumor progression. Enucleation may be necessary in approximately 10% of patients. We conclude that malignant melanoma of the uvea can be safely treated with radioactive plaques. (orig./MG) [de

  1. Manual on brachytherapy. Incorporating: Applications guide, procedures guide, basics guide

    International Nuclear Information System (INIS)

    1996-01-01

    This publication is part of practical radiation safety manual series for different fields of application aimed primarily at persons handling radiation sources on a daily routine basis, which could at same time be used by the competent authorities, supporting their efforts in the radiation protection training of workers or medical assistance personnel or helping on-site management to set up local radiation protection rules. It is dedicated to brachytherapy: its application and procedures guides

  2. Demonstration of brachytherapy boost dose-response relationships in glioblastoma multiforme

    International Nuclear Information System (INIS)

    Sneed, Penny K.; Lamborn, Kathleen R.; Larson, David A.; Prados, Michael D.; Malec, Mary K.; McDermott, Michael W.; Weaver, Keith A.; Phillips, Theodore L.; Wara, William M.; Gutin, Philip H.

    1996-01-01

    Purpose: To evaluate brachytherapy dose-response relationships in adults with glioblastoma undergoing temporary 125 I implant boost after external beam radiotherapy. Methods and Materials: Since June 1987, orthogonal radiographs using a fiducial marker box have been used to verify brain implant source positions and generate dose-volume histograms at the University of California, San Francisco. For adults who underwent brachytherapy boost for glioblastoma from June 1987 through December 1992, tumor volumes were reoutlined to ensure consistency and dose-volume histograms were recalculated. Univariate and multivariate analyses of various patient and treatment parameters were performed evaluating for influence of dose on freedom from local failure (FFLF) and actuarial survival. Results: Of 102 implant boosts, 5 were excluded because computer plans were unavailable. For the remaining 97 patients, analyses with adjustment for known prognostic factors (age, KPS, extent of initial surgical resection) and prognostic factors identified on univariate testing (adjuvant chemotherapy) showed that higher minimum brachytherapy tumor dose was strongly associated with improved FFLF (p = 0.001). A quadratic relationship was found between total biological effective dose and survival, with a trend toward optimal survival probability at 47 Gy minimum brachytherapy tumor dose (corresponding to about 65 Gy to 95% of the tumor volume); survival decreased with lower or higher doses. Two patients expired and one requires hospice care because of brain necrosis after brachytherapy doses > 63 Gy to 95% of the tumor volume with 60 Gy to > 18 cm 3 of normal brain. Conclusion: Although higher minimum brachytherapy tumor dose was strongly associated with better local control, a brachytherapy boost dose > 50-60 Gy may result in life-threatening necrosis. We recommend careful conformation of the prescription isodose line to the contrast enhancing tumor volume, delivery of a minimum brachytherapy

  3. Inverse planning in brachytherapy from radium to high rate 192 iridium afterloading

    International Nuclear Information System (INIS)

    Lahanas, M.; Mould, R.F.; Baltas, D.; Karauzakis, K.; Giannouli, S.; Baltas, D.

    2004-01-01

    We consider the inverse planning problem in brachytherapy, i.e. the problem to determine an optimal number of catheters, number of sources for low-dose rate brachytherapy (LDR) and the optimal dwell times for high-dose rate brachytherapy (HDR) necessary to obtain an optimal as possible dose distribution. Starting from the 1930s, inverse planning for LDR brachytherapy used geometrically derived rules to determine the optimal placement of sources in order to achieve a uniform dose distribution of a specific level in planes, spheres and cylinders. Rules and nomograms were derived which still are widely used. With the rapid development of 3D imaging technologies and the rapidly increasing computer power we have now entered the new era of computer-based inverse planning in brachytherapy. The inverse planning is now an optimisation process adapted to the individual geometry of the patient. New inverse planning optimisation algorithms are anatomy-based that consider the real anatomy of the tumour and the organs at risk (OAR). Computer-based inverse planning considers various effects such as stability of solutions for seed misplacements which cannot ever be solved analytically without gross simplifications. In the last few years multiobjective (MO) inverse planning algorithms have been developed which recognise the MO optimisation problem which is inherent in inverse planning in brachytherapy. Previous methods used a trial and error method to obtain a satisfactory solution. MO optimisation replaces this trial and error process by presenting a representative set of dose distributions that can be obtained. With MO optimisation it is possible to obtain information that can be used to obtain the optimum number of catheters, their position and the optimum distribution of dwell times for HDR brachytherapy. For LDR brachytherapy also the stability of solutions due to seed migration can also be improved. A spectrum of alternative solutions is available and the treatment planner

  4. Intravascular catheter-related bloodstream infection.

    Science.gov (United States)

    Shah, Harshal; Bosch, Wendelyn; Thompson, Kristine M; Hellinger, Walter C

    2013-07-01

    Intravascular catheters required for the care of many hospitalized patients can give rise to bloodstream infection, a complication of care that has occurred most frequently in intensive care unit (ICU) settings. Elucidation of the pathogenesis of catheter-related bloodstream infections (CRBSIs) has guided development of effective diagnostic, management, and prevention strategies. When CRBSIs occur in the ICU, physicians must be prepared to recognize and treat them. Prevention of these infections requires careful attention to optimal catheter selection, insertion and maintenance, and to removal of catheters when they are no longer needed. This review provides a succinct summary of the epidemiology, pathogenesis, and microbiology of CRBSIs and a review of current guidance for the diagnosis, management, and prevention of these infections.

  5. Death following intravascular administration of contrast media

    International Nuclear Information System (INIS)

    Shehadi, W.H.

    1985-01-01

    Adverse reactions to intravascularly administered contrast media preceding death and the autopsy findings in 44 patients are presented. There is a wide scatter of the age distribution of fatal reactions. The highest incidence is in the 50-70 year age group. Similar observations were obtained from the 405 deaths due to contrast media reported to the Food and Drug Administration of the United States. In the same age group the number of reactions is highest, likewise the autopsy findings. The predominant autopsy findings are pulmonary edema, congestion and hemorrhage; arteriosclerosis, both general and coronary. In the younger age group the autopsy findings are limited mostly to the respiratory tract. Fatal reactions to contrast media occur often without warning and most deaths occur within 15 min to 6 hours. Reactions to contrast media occur without relation to sex or age. (orig.)

  6. Quinine-Induced Disseminated Intravascular Coagulation

    Directory of Open Access Journals (Sweden)

    Firas Abed

    2016-01-01

    Full Text Available Every drug comes with some side effect. It is the benefit/risk ratio that determines the medical use of the drug. Quinine, a known antimalarial drug, has been used for nocturnal leg cramps since the 1930s; it is associated with severe life-threatening hematological and cardiovascular side effects. Disseminated intravascular coagulation (DIC, albeit rare, is a known coagulopathy associated with Quinine. It is imperative to inquire about the Quinine intake in medication history in patients with coagulopathy, as most patients still consider it a harmless home remedy for nocturnal leg cramps. In this report, we present a case of coagulopathy in a middle-aged woman, who gave a history of taking Quinine for nocturnal leg cramps, as her home remedy. Early identification of the offending agent led to the diagnosis, prompt discontinuation of the medication, and complete recovery and prevented the future possibility of recurrence.

  7. Chronic Disseminated Intravascular Coagulation: A Case Report

    Directory of Open Access Journals (Sweden)

    Md Abul Kalam Azad

    2009-11-01

    Full Text Available In health there is a balance between the coagulation and anti-coagulation systems, but in disseminated intravascular coagulation (DIC the coagulation mechanism is activated inappropriately and in a diffuse way. This may lead to thrombosis, but more often haemorrhage occurs when the clotting factors are exhausted. DIC may present as acute, subacute, and rarely chronic form. Here we present a case of chronic DIC following pelvic inflammatory disease (PID as a consequence of repeated menstruation regulation (MR. We treated her with fresh frozen plasma, fresh blood, doxycycline with significant clinical improvement.DOI: 10.3329/bsmmuj.v1i1.3696 BSMMU J 2008; 1(1: 33-34

  8. Ventricular metastasis resulting in disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Davis Ian D

    2005-05-01

    Full Text Available Abstract Background Disseminated Intravascular Coagulation (DIC complicates up to 7% of malignancies, the commonest solid organ association being adenocarcinoma. Transitional Cell Carcinoma (TCC has rarely been associated with DIC. Case presentation A 74-year-old woman with TCC bladder and DIC was found to have a cardiac lesion suspicious for metastatic disease. The DIC improved with infusion of plasma and administration of Vitamin K, however the cardiac lesion was deemed inoperable and chemotherapy inappropriate; given the patients functional status. We postulate that direct activation of the coagulation cascade by the intraventricular metastasis probably triggered the coagulopathy in this patient. Conclusion Cardiac metastases should be considered in cancer patients with otherwise unexplained DIC. This may influence treatment choices.

  9. Human error in remote Afterloading Brachytherapy

    International Nuclear Information System (INIS)

    Quinn, M.L.; Callan, J.; Schoenfeld, I.; Serig, D.

    1994-01-01

    Remote Afterloading Brachytherapy (RAB) is a medical process used in the treatment of cancer. RAB uses a computer-controlled device to remotely insert and remove radioactive sources close to a target (or tumor) in the body. Some RAB problems affecting the radiation dose to the patient have been reported and attributed to human error. To determine the root cause of human error in the RAB system, a human factors team visited 23 RAB treatment sites in the US. The team observed RAB treatment planning and delivery, interviewed RAB personnel, and performed walk-throughs, during which staff demonstrated the procedures and practices used in performing RAB tasks. Factors leading to human error in the RAB system were identified. The impact of those factors on the performance of RAB was then evaluated and prioritized in terms of safety significance. Finally, the project identified and evaluated alternative approaches for resolving the safety significant problems related to human error

  10. High-dose-rate brachytherapy for uterine cervical cancer: the results of different fractionation regimen

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Won Sup; Kim, Tae Hyun; Yang, Dae Sik; Choi, Myung Sun; Kim, Chul Yong [College of Medicine, Korea University, Seoul (Korea, Republic of)

    2002-09-15

    Although high-dose-rate (HDR) brachytherapy regimens have been practiced with a variety of modalities and various degrees of success, few studies on the subject have been conducted. The purpose of this study was to compare the results of local control and late complication rate according to different HDR brachytherapy fractionation regimens in uterine cervical cancer patients. From November 1992 to March 1998, 224 patients with uterine cervical cancer were treated with external beam irradiation and HDR brachytherapy. In external pelvic radiation therapy, the radiation dose was 45 {approx} 54 Gy (median dose 54 Gy) with daily fraction size 1.8 Gy, five times per week. In HDR brachytherapy, 122 patients (Group A) were treated with three times weekly with 3 Gy to line-A (isodose line of 2 cm radius from source) and 102 patients (Group B) underwent the HDR brachytherapy twice weekly with 4 or 4.5 Gy to line-A after external beam irradiation. Iridium-192 was used as the source of HDR brachytherapy. Late complication was assessed from grade 1 to 5 using the RTOG morbidity grading system. The local control rate (LCR) at 5 years was 80% in group A and 84% in group B ({rho} = 0.4523). In the patients treated with radiation therapy alone, LCR at 5 years was 60.9% in group A and 76.9% in group B ({rho} = 0.2557). In post-operative radiation therapy patients, LCR at 5 years was 92.6% in group A and 91.6% in group B ({rho} 0.8867). The incidence of late complication was 18% (22 patients) and 29.4% (30 patients), of bladder complication was 9.8% (12 patients) and 14.7% (15 patients), and of rectal complication was 9.8% (12 patients) and 21.6% (22 patients), in group A and B, respectively. Lower fraction sized HDR brachytherapy was associated with decrease in late complication ({rho} =0.0405) (rectal complication, {rho} = 0.0147; bladder complication, {rho} =0.115). The same result was observed in postoperative radiation therapy patients ({rho} = 0.0860) and radiation only

  11. Paddle-based rotating-shield brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yunlong; Xu, Weiyu [Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center, Iowa City, Iowa 52242 (United States); Flynn, Ryan T.; Kim, Yusung; Bhatia, Sudershan K.; Buatti, John M. [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States); Dadkhah, Hossein [Department of Biomedical Engineering, University of Iowa, 1402 Seamans Center, Iowa City, Iowa 52242 (United States); Wu, Xiaodong, E-mail: xiaodong-wu@uiowa.edu [Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center, Iowa City, Iowa 52242 and Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States)

    2015-10-15

    Purpose: The authors present a novel paddle-based rotating-shield brachytherapy (P-RSBT) method, whose radiation-attenuating shields are formed with a multileaf collimator (MLC), consisting of retractable paddles, to achieve intensity modulation in high-dose-rate brachytherapy. Methods: Five cervical cancer patients using an intrauterine tandem applicator were considered to assess the potential benefit of the P-RSBT method. The P-RSBT source used was a 50 kV electronic brachytherapy source (Xoft Axxent™). The paddles can be retracted independently to form multiple emission windows around the source for radiation delivery. The MLC was assumed to be rotatable. P-RSBT treatment plans were generated using the asymmetric dose–volume optimization with smoothness control method [Liu et al., Med. Phys. 41(11), 111709 (11pp.) (2014)] with a delivery time constraint, different paddle sizes, and different rotation strides. The number of treatment fractions (fx) was assumed to be five. As brachytherapy is delivered as a boost for cervical cancer, the dose distribution for each case includes the dose from external beam radiotherapy as well, which is 45 Gy in 25 fx. The high-risk clinical target volume (HR-CTV) doses were escalated until the minimum dose to the hottest 2 cm{sup 3} (D{sub 2cm{sup 3}}) of either the rectum, sigmoid colon, or bladder reached their tolerance doses of 75, 75, and 90 Gy{sub 3}, respectively, expressed as equivalent doses in 2 Gy fractions (EQD2 with α/β = 3 Gy). Results: P-RSBT outperformed the two other RSBT delivery techniques, single-shield RSBT (S-RSBT) and dynamic-shield RSBT (D-RSBT), with a properly selected paddle size. If the paddle size was angled at 60°, the average D{sub 90} increases for the delivery plans by P-RSBT on the five cases, compared to S-RSBT, were 2.2, 8.3, 12.6, 11.9, and 9.1 Gy{sub 10}, respectively, with delivery times of 10, 15, 20, 25, and 30 min/fx. The increases in HR-CTV D{sub 90}, compared to D-RSBT, were 16

  12. Dose calculation and isodose curves determination in brachytherapy

    International Nuclear Information System (INIS)

    Maranhao, Frederico B.; Lima, Fernando R.A.; Khoury, Helen J.

    2000-01-01

    Brachytherapy is a form of cancer treatment in which small radioactive sources are placed inside of, or close to small tumors, in order to cause tissue necrosis and, consequently, to interrupt the tumor growth process. A very important aspect to the planning of this therapy is the calculation of dose distributions in the tumor and nearby tissues, to avoid the unnecessary irradiation of healthy tissue. The objective of this work is to develop a computer program that will permit treatment planning for brachytherapy at low dose rates, minimizing the possible errors introduced when such calculations are done manually. Results obtained showed good agreement with those from programs such as BRA, which is widely used in medical practice. (author)

  13. [Basic principles and results of brachytherapy in gynecological oncology].

    Science.gov (United States)

    Kanaev, S V; Turkevich, V G; Baranov, S B; Savel'eva, V V

    2014-01-01

    The fundamental basics of contact radiation therapy (brachytherapy) for gynecological cancer are presented. During brachytherapy the principles of conformal radiotherapy should be implemented, the aim of which is to sum the maximum possible dose of radiation to the tumor and decrease the dose load in adjacent organs and tissues, which allows reducing the frequency of radiation damage at treatment of primary tumors. It is really feasible only on modern technological level, thanks to precision topometry preparation, optimal computer dosimetrical and radiobiological planning of each session and radiotherapy in general. Successful local and long-term results of the contact radiation therapy for cancer of cervix and endometrium are due to optimal anatomical and topometrical ratio of the tumor localization, radioactive sources, and also physical and radiobiological laws of distribution and effects of ionizing radiation, the dose load accounting rules.

  14. Radiation Protection in Brachytherapy. Report of the SEFM Task Group on Brachytherapy; Proteccion radiologica en Braquiterapia. Informe del grupo de trabajo de Braquiterapia de la SEFM

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Calatayud, J.; Corredoira Silva, E.; Crispin Contreras, V.; Eudaldo Puell, T.; Frutos Baraja, J. de; Pino Sorroche, F.; Pujades Claumarchirant, M. C.; Richart Sancho, J.

    2015-07-01

    This document presents the report of the Brachytherapy Task Group of the Spanish Society of Medical Physics. It is dedicated to the radiation protection aspects involved in brachytherapy. The aim of this work is to include the more relevant aspects related to radiation protection issues that appear in clinical practice, and for the current equipment in Spain. Basically this report focuses on the typical contents associated with high dose rate brachytherapy with {sup 1}92Ir and {sup 6}0Co sources, and permanent seed implants with {sup 1}25I, {sup 1}03Pd and {sup 1}31Cs, which are the most current and widespread modalities. Ophthalmic brachytherapy (COMS with {sup 1}25I, {sup 1}06Ru, {sup 9}0Sr) is also included due to its availability in a significant number of spanish hospitals. The purpose of this report is to assist to the medical physicist community in establishing a radiation protection program for brachytherapy procedures, trying to solve some ambiguities in the application of legal requirements and recommendations in clinical practice. (Author)

  15. 78 FR 41125 - Interim Enforcement Policy for Permanent Implant Brachytherapy Medical Event Reporting

    Science.gov (United States)

    2013-07-09

    ... delivered dose to prescribed dose can be done with doses expressed as total source strength and exposure... for manual brachytherapy in Sec. 35.2, Definitions, permits the doses to be expressed as total source... performed in terms of absorbed dose to determine whether a medical event has occurred. Section 35.3045(a)(1...

  16. Education and Propagation of Intravascular Surgery in Okinawa

    Science.gov (United States)

    Harakuni, T.; Hyodo, A.; Shingaki, T.; Kugai, M.; Kinjyo, T.; Kinjyo, T.; Tsuchida, H.; Sugimoto, K.; Yoshii, Y.

    2004-01-01

    Summary Okinawa is an island located on the southwest edge of the Japanese Islands in which about 1,300,000 people live, and is an area where self-conclusion type medical treatment is desired. In this area, intravascular surgery was only performed for several cases per year until 1998. From May 1999, intravascular surgery started being performed in earnest, and 140 or more cases of intravascular surgery per year were performed in 2002. In the meantime, various measures for the propagation and development of intravascular surgery that we undertook led to the increase in the number of cases. As a result, the choice of medical treatment has increased by propagating these medical treatments, and it seems that this has contributed to the welfare of the people of Okinawa. PMID:20587285

  17. Preparation of a program for the independent verification of the brachytherapy planning systems calculations

    International Nuclear Information System (INIS)

    V Carmona, V.; Perez-Calatayud, J.; Lliso, F.; Richart Sancho, J.; Ballester, F.; Pujades-Claumarchirant, M.C.; Munoz, M.

    2010-01-01

    In this work a program is presented that independently checks for each patient the treatment planning system calculations in low dose rate, high dose rate and pulsed dose rate brachytherapy. The treatment planning system output text files are automatically loaded in this program in order to get the source coordinates, the desired calculation point coordinates and the dwell times when it is the case. The source strength and the reference dates are introduced by the user. The program allows implementing the recommendations about independent verification of the clinical brachytherapy dosimetry in a simple and accurate way, in few minutes. (Author).

  18. Afterloading: The Technique That Rescued Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Aronowitz, Jesse N., E-mail: jesse.aronowitz@umassmemorial.org

    2015-07-01

    Although brachytherapy had been established as a highly effective modality for the treatment of cancer, its application was threatened by mid-20th century due to appreciation of the radiation hazard to health care workers. This review examines how the introduction of afterloading eliminated exposure and ushered in a brachytherapy renaissance.

  19. Intravascular Large B-Cell Lymphoma

    Directory of Open Access Journals (Sweden)

    Maria S. Khan MD, FACP

    2014-03-01

    Full Text Available Case Presentation . A 69-year-old Hispanic male, with a past history of diabetes and coronary disease, was admitted for fever, diarrhea, and confusion of 4 weeks duration. Physical examination showed a disoriented patient with multiple ecchymoses, possible ascites, and bilateral scrotal swelling. Hemoglobin was 6.7, prothrombin time (PT 21.4 seconds with international normalized ratio 2.1, partial thromboplastin time (PTT 55.6 seconds, fibrin split 10 µg/L, and lactate dehydrogenase (LDH 1231 IU/L. Except for a positive DNA test for Epstein–Barr virus (EBV infection, extensive diagnostic workup for infections, malignancy, or a neurological cause was negative. Mixing studies revealed a nonspecific inhibitor of PT and PTT but Factor VIII levels were normal. The patient was empirically treated with antibiotics but developed hypotension and died on day 27 of admission. At autopsy, patient was found to have intravascular diffuse large B-cell lymphoma involving skin, testes, lung, and muscles. The malignant cells were positive for CD20, CD791, Mum-1, and Pax-5 and negative for CD3, CD5, CD10, CD30, and Bcl-6. The malignant cells were 100% positive for Ki-67. Discussion . Intravascular large cell B-cell lymphoma (IVLBCL is rare form of diffuse large B-cell lymphoma and tends to proliferate within small blood vessels, particularly capillaries and postcapillary venules. The cause of its affinity for vascular bed remains unknown. In many reports, IVLBCL was associated with HIV, HHV8, and EBV infections. The fact that our case showed evidence of EBV infection lends support to the association of this diagnosis to viral illness. The available literature on this subject is scant, and in many cases, the diagnosis was made only at autopsy. The typical presentation of this disorder is with B symptoms, progressive neurologic deficits, and skin findings. Bone marrow, spleen, and liver are involved in a minority of patients. Nearly all patients have elevated LDH

  20. [Intravascular lymphomatosis. A report of three cases].

    Science.gov (United States)

    Menéndez Calderón, M J; Seguí Riesco, M E; Argüelles, M; Nuño Mateo, J

    2005-01-01

    Intravascular lymphomatosis (IVL) is a rare malignancy characterized by a proliferation of atypical lymphoid cells occluding small blood vessels (venules, capillaries and small arteries). The symptoms are caused by embolisms due to massive proliferation. Nervous system and skin are the most common sites of involvement but all organs may be involved, although it is typified by the absence of malignant cells in lymphoid tissues. We describe three cases of IVL: first patient was a 57 years old man with rapidly progressive dementia and neurological involvements and second case of a 69 years old man hospitalised with predominant symptoms in the lung (cough, dyspnea and fever), and a woman presenting as fever of unknown origin (FUO) with systemic inflammatory response syndrome. In all cases that we reported have been diagnosed post-mortem because of rapid progression of a multisystem disease and the absence of pathognomonic clinical manifestations. Diagnosis can be made using biopsy of one of the involved organs. In conclusion, we propose that IVL should be included in the differential diagnosis of acute confusional state, dementia or other unexplained neurological manifestations, fever of unknown origin, vasculitis, occult neoplasia or infections with signs of a systemic disease and marked elevation of serum lactate dehydrogenase (LDH).

  1. Disseminated intravascular coagulation in solid tumors

    International Nuclear Information System (INIS)

    Terzieff, V.; Alonso, I.; Vázquez, A.

    2004-01-01

    It is estimated that 20-25% of cases of disseminated intravascular coagulation (DIC) relate to an underlying neoplasia primarily hematologic. It is estimated that about 5% of patients with solid tumors have CID clinic, although the incidence of subclinical alterations is much higher. The CID is not limited to the activation of the coagulation cascade, which leads to bleeding micro thrombosis and consumption of coagulation factors. Solid tumors are frequently associated adenocarcinomas producers mucin (especially gastric), usually in the context of a disseminated disease. The mucin may act as a promoter of the cascade, but probably it is a multi-event. High levels of TNF to produced by the tumor mass and chemotherapy-induced cell lysis have Also linked. Although the bleeding is usually oriented diagnosis, the most frequent cause of death is thrombosis. There are no specific tests for diagnosis. Elevated levels of D-dimer and products oriented fibrinogen degradation diagnosis. No reduction fibrinogen and almost always, one thrombocytopenia consumption. Treatment is complex and there is no consensus on many points. To recover the lost factors for consumption, it is recommended to use fresh frozen plasma and / or washed red blood cells. the heparin anticoagulation low dose is indicated since the disease causal can not be controlled quickly, but should not be initiated if there thrombocytopenia 50.000.El under profuse bleeding can require the use of tranexamic acid or EACA. Acute DIC, the case of our patient, is rare and very serious

  2. Monte Carlo Dose Calculation of 90 Sr/ 90 Y Source in Water Phantom

    Directory of Open Access Journals (Sweden)

    Ali Asghar Mowlavi

    2008-06-01

    Full Text Available Introduction:  90 Sr/ 90 Y source  has  been  used  for  the  intravascular  brachytherapy  to  prevent  coronary  restenosis in the patients who have undergone angioplasty. The aim of this research is to determine the  dose distribution of  90 Sr/ 90 Y source in a water phantom.  Materials  and  Methods:  In  the  present  work,  MCNP  code  has  been  applied  to  calculate  the  dose  distribution around a 3 cm length of  90 Sr/ 90 Y source in a 30×30×30 cm 3 water phantom. Also, the exact  geometry  of  the  source  has  been  used  in  this  simulation.  Tally  *F8:e  which  is  suitable  for  beta  ray  dosimetry has been evaluated with less than %5 relative error in a sphere having 0.2 mm radius.  Results:  The  isodose  curve  for  10,  20,  40,  and  90%  depth  dose  (PDD  were  derived  based  on  the  calculated dose curves along the parallel and perpendicular axis to the source.  Discussion  and  Conclusion:  The  results  obtained  in  this  work  are  in  a  good  agreement  with  the  experimental  result  published  by  Buckley  et  al.  and  the  International  Atomic  Energy  Agency  (IAEA  report  in  a  water  phantom.    Therefore,  the  result  of  this  research  can  be  used  in  the  intravascular  brachytherapy.

  3. Matlab Tools: An Alternative to Planning Systems in Brachytherapy Treatments

    International Nuclear Information System (INIS)

    Herrera, Higmar; Rodriguez, Mercedes; Rodriguez, Miguel

    2006-01-01

    This work proposes the use of the Matlab environment to obtain the treatment dose based on the reported data by Krishnaswamy and Liu et al. The comparison with reported measurements is showed for the Amersham source model. For the 3M source model, measurements with TLDs and a Monte Carlo simulation are compared to the data obtained by Matlab. The difference for the Amersham model is well under the 15% recommended by the IAEA and for the 3M model, although the difference is greater, the results are consistent. The good agreement to the reported data allows the Matlab calculations to be used in daily brachytherapy treatments

  4. Automatic analysis of intrinsic positional verification films brachytherapy using MATLAB

    International Nuclear Information System (INIS)

    Quiros Higueras, J. D.; Marco Blancas, N. de; Ruiz Rodriguez, J. C.

    2011-01-01

    One of the essential tests in quality control of brachytherapy equipment is verification auto load intrinsic positional radioactive source. A classic method for evaluation is the use of x-ray film and measuring the distance between the marks left by autoradiography of the source with respect to a reference. In our center has developed an automated method of measurement by the radiochromic film scanning and implementation of a macro developed in Matlab, in order to optimize time and reduce uncertainty in the measurement. The purpose of this paper is to describe the method developed, assess their uncertainty and quantify their advantages over the manual method. (Author)

  5. Interstitial rotating shield brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Adams, Quentin E.; Xu, Jinghzu; Breitbach, Elizabeth K.; Li, Xing; Rockey, William R.; Kim, Yusung; Wu, Xiaodong; Flynn, Ryan T.; Enger, Shirin A.

    2014-01-01

    Purpose: To present a novel needle, catheter, and radiation source system for interstitial rotating shield brachytherapy (I-RSBT) of the prostate. I-RSBT is a promising technique for reducing urethra, rectum, and bladder dose relative to conventional interstitial high-dose-rate brachytherapy (HDR-BT). Methods: A wire-mounted 62 GBq 153 Gd source is proposed with an encapsulated diameter of 0.59 mm, active diameter of 0.44 mm, and active length of 10 mm. A concept model I-RSBT needle/catheter pair was constructed using concentric 50 and 75 μm thick nickel-titanium alloy (nitinol) tubes. The needle is 16-gauge (1.651 mm) in outer diameter and the catheter contains a 535 μm thick platinum shield. I-RSBT and conventional HDR-BT treatment plans for a prostate cancer patient were generated based on Monte Carlo dose calculations. In order to minimize urethral dose, urethral dose gradient volumes within 0–5 mm of the urethra surface were allowed to receive doses less than the prescribed dose of 100%. Results: The platinum shield reduced the dose rate on the shielded side of the source at 1 cm off-axis to 6.4% of the dose rate on the unshielded side. For the case considered, for the same minimum dose to the hottest 98% of the clinical target volume (D 98% ), I-RSBT reduced urethral D 0.1cc below that of conventional HDR-BT by 29%, 33%, 38%, and 44% for urethral dose gradient volumes within 0, 1, 3, and 5 mm of the urethra surface, respectively. Percentages are expressed relative to the prescription dose of 100%. For the case considered, for the same urethral dose gradient volumes, rectum D 1cc was reduced by 7%, 6%, 6%, and 6%, respectively, and bladder D 1cc was reduced by 4%, 5%, 5%, and 6%, respectively. Treatment time to deliver 20 Gy with I-RSBT was 154 min with ten 62 GBq 153 Gd sources. Conclusions: For the case considered, the proposed 153 Gd-based I-RSBT system has the potential to lower the urethral dose relative to HDR-BT by 29%–44% if the clinician allows

  6. Rotational multispectral fluorescence lifetime imaging and intravascular ultrasound: bimodal system for intravascular applications

    Science.gov (United States)

    Ma, Dinglong; Bec, Julien; Yankelevich, Diego R.; Gorpas, Dimitris; Fatakdawala, Hussain; Marcu, Laura

    2014-06-01

    We report the development and validation of a hybrid intravascular diagnostic system combining multispectral fluorescence lifetime imaging (FLIm) and intravascular ultrasound (IVUS) for cardiovascular imaging applications. A prototype FLIm system based on fluorescence pulse sampling technique providing information on artery biochemical composition was integrated with a commercial IVUS system providing information on artery morphology. A customized 3-Fr bimodal catheter combining a rotational side-view fiberoptic and a 40-MHz IVUS transducer was constructed for sequential helical scanning (rotation and pullback) of tubular structures. Validation of this bimodal approach was conducted in pig heart coronary arteries. Spatial resolution, fluorescence detection efficiency, pulse broadening effect, and lifetime measurement variability of the FLIm system were systematically evaluated. Current results show that this system is capable of temporarily resolving the fluorescence emission simultaneously in multiple spectral channels in a single pullback sequence. Accurate measurements of fluorescence decay characteristics from arterial segments can be obtained rapidly (e.g., 20 mm in 5 s), and accurate co-registration of fluorescence and ultrasound features can be achieved. The current finding demonstrates the compatibility of FLIm instrumentation with in vivo clinical investigations and its potential to complement conventional IVUS during catheterization procedures.

  7. Study and development of methodology for radioactive iodine fixation in polymeric substrate for manufacturing sources used in brachytherapy; Estudo e desenvolvimento de metodologia para fixacao de iodo radioativo em substrato polimerico para confeccao de fontes utilizadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Bruna T.; Souza, Carla D.; Benega, Marcos A.G. and others, E-mail: bteigarodrigues@gmail.com, E-mail: carladdsouza@yahoo.com.br, E-mail: marcosagbenega@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes

    2014-07-01

    According global estimates of Globocan 2012 project of the International Agency for Research of Cancer, of the World Health Organization, there were 14,1 million new cases of cancer and a total of 8,2 million deaths from cancer. Also show that in 2030, the overall load will be 21,4 million new cases and 13,2 million cancer deaths. One of the prostate cancer therapy is brachytherapy, used in early and middle stages of the disease. It is made with the introduction of seeds with radioactive material within the tumor or in nearby regions, affecting the minimum surrounding tissues. The aim of this work is the study and developing the deposition of radioactive iodine on the polymeric substrate method, and an analysis relating the efficiency of the method to implementation in the laboratory of brachytherapy from IPEN. Iodine-125 is adsorbed on an epoxy resin solution. The objective of this study is to offer a new proposal for seeds. The results will give the data for the radiation protection and the procedures for radioactive waste management.

  8. American Brachytherapy Society recommendations for reporting morbidity after prostate brachytherapy

    International Nuclear Information System (INIS)

    Nag, Subir; Ellis, Rodney J.; Merrick, Gregory S.; Bahnson, Robert; Wallner, Kent; Stock, Richard

    2002-01-01

    Purpose: To standardize the reporting of brachytherapy-related prostate morbidity to guide ongoing clinical practice and future investigations. Methods: Members of the American Brachytherapy Society (ABS) with expertise in prostate brachytherapy performed a literature review and, guided by their clinical experience, formulated specific recommendations for reporting on morbidity related to prostate brachytherapy. Results: The ABS recommends using validated, patient-administered health-related quality-of-life instruments for the determination of baseline and follow-up data regarding bowel, urinary, and sexual function. Both actuarial and crude incidences should be reported, along with the temporal resolution of specific complications, and correlated with the doses to the normal tissues. The International Prostate Symptom Score is recommended to assess urinary morbidity, and any dysuria, gross hematuria, urinary retention, incontinence, or medication use should be quantified. Likewise, the ''Sexual Health Inventory for Men,'' which includes the specific erectile questions of the International Index of Erectile Function, is the preferred instrument for reporting sexual function, and the loss of sexual desire, incidence of hematospermia, painful orgasm (orgasmalgia), altered orgasm intensity, decreased ejaculatory volume, use of erectile aids, and use of hormones for androgen deprivation should be quantified. The ABS recommends adoption of the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer acute and late radiation morbidity scoring scheme for reporting rectal morbidity and noting the incidence of rectal steroid, laser, or antidiarrheal use. Conclusion: It is important to focus on health-related quality-of-life issues in the treatment of prostate cancer, because the control rates are very similar between appropriate treatment modalities. The ABS recommends using the International Prostate Symptom Score, International Index of

  9. Radiological protection of patients in brachytherapy

    International Nuclear Information System (INIS)

    Sacc, Ricardo; Herrero, Flavia

    2008-01-01

    Full text: The prefix 'brachy' means short-range, so brachytherapy is the administration of radiation therapy using small radioactive sources in the form of needles, tubes, wires or seeds, which are placed within the tumor -interstitial form- or very near of it, superficially or in an endo-cavity form. This technique, which was limited by the size of the primary tumor, has the advantage, that the radiation, can be adjusted to the size and shape of the tumor volume and the radioisotope used, - short range -, is selected with the criteria of getting the dose in the organs at risk, as low as possible, making what it is known as conformal radiotherapy. Radioactive sources may be permanent or temporary implants. The application of radioactive material, can be manually or automatically. In the first case, a major breakthrough from the radioprotection point of view, was the use of afterloading devices, methodology highly recommended to reduce the radiation exposure to staff. With the development of technology, remotely controlled afterloading devices were introduced, which in addition to complying with the above requirement, allow the source to move in different positions along catheters housed in one or more channels, making therapeutic brachytherapy treatments in tumor volumes possible, that due to its length, decades ago would have been an unthinkable deal. In all cases, sources, which may vary from the 3 mm in length, 125 Iodine or 198 Gold seeds, to extensive wires of 192 Iridium, are encapsulated for two main purposes: preventing leakage of radioactive material and absorption of unwanted radiation, alpha and beta, produced by the radioactive decay. Consequently, it should be highly unlikely that the radioactive material, could be lost or located in the patient, in a different place of the one that was planned. However, history shows us the opposite. Its is known the kind of deterministic effect that radiation is going to produce in the tumor, where the severity of

  10. MO-D-BRD-01: Clinical Implementation of An Electronic Brachytherapy Program for the Skin

    International Nuclear Information System (INIS)

    Ouhib, Z.

    2015-01-01

    Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic

  11. Monte Carlo dose calculations for high-dose-rate brachytherapy using GPU-accelerated processing.

    Science.gov (United States)

    Tian, Z; Zhang, M; Hrycushko, B; Albuquerque, K; Jiang, S B; Jia, X

    2016-01-01

    Current clinical brachytherapy dose calculations are typically based on the Association of American Physicists in Medicine Task Group report 43 (TG-43) guidelines, which approximate patient geometry as an infinitely large water phantom. This ignores patient and applicator geometries and heterogeneities, causing dosimetric errors. Although Monte Carlo (MC) dose calculation is commonly recognized as the most accurate method, its associated long computational time is a major bottleneck for routine clinical applications. This article presents our recent developments of a fast MC dose calculation package for high-dose-rate (HDR) brachytherapy, gBMC, built on a graphics processing unit (GPU) platform. gBMC-simulated photon transport in voxelized geometry with physics in (192)Ir HDR brachytherapy energy range considered. A phase-space file was used as a source model. GPU-based parallel computation was used to simultaneously transport multiple photons, one on a GPU thread. We validated gBMC by comparing the dose calculation results in water with that computed TG-43. We also studied heterogeneous phantom cases and a patient case and compared gBMC results with Acuros BV results. Radial dose function in water calculated by gBMC showed GPU-based MC dose calculation package, gBMC, for HDR brachytherapy make it attractive for clinical applications. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  12. Three-dimensional brachytherapy optimization techniques in the treatment of patients with cervix cancer

    International Nuclear Information System (INIS)

    Haie-Meder, C.; Mazeron, R.; Verezesan, O.; Monnier, L.; Vieillot, S.; Dumas, I.; Lhomme, C.; Morice, P.; Barillot, I.

    2009-01-01

    Traditionally, prescription and treatment planning in intracavitary brachytherapy for cervix cancer have used either reference points (mainly points A and B) or reference isodoses (60 Gy according to ICRU recommendations) to report doses to the target volume. Doses to critical organs were reported at bladder and rectum ICRU points. This practice has been supported by a long-standing clinical experience that has yielded an acceptable therapeutic ratio. The recent development of imaging has contributed to the improvement in target and organs at risk knowledge. In 2005 and 2006, the European group of brachytherapy -European Society for therapeutic radiology and oncology (GEC-E.S.T.R.O.) recommendations publications on 3-D based image brachytherapy have defined the different volumes of interest. These recommendations have been validated with intercomparison delineation studies. With the concomitant development of remote after-loading projectors, provided with miniaturized sources, it is now possible to plan radiation doses by adjusting dwell positions and relative dwell time values. These procedures allow better coverage of the targets while sparing O.A.R.. The recent literature data evidence a significant improvement in local control with no increase in complications. Further studies are needed to better define the dose recommended in both tumour and organs at risk. This is one of the goals of the European study on MRI-guided brachytherapy in locally advanced cervical cancer (E.M.B.R.A.C.E.) protocol (meaning of acronym: an international study on MRI-guided brachytherapy in locally advanced cervical cancer). (authors)

  13. Intraoperative planning and evaluation of permanent prostate brachytherapy: report of the American Brachytherapy Society.

    Science.gov (United States)

    Nag, S; Ciezki, J P; Cormack, R; Doggett, S; DeWyngaert, K; Edmundson, G K; Stock, R G; Stone, N N; Yu, Y; Zelefsky, M J

    2001-12-01

    methods of enhancing seed identification, in imaging techniques, and in the development of better source delivery systems. Additionally, ITP should be correlated with outcome studies, using dosimetric, toxicity, and efficacy endpoints. ITP addresses many of the limitations of current permanent prostate brachytherapy and has some advantages over the preplanned technique. Further technologic advancement will be needed to achieve dynamic real-time calculation of dose distribution from implanted sources, with constant updating to allow modification of subsequent seed placement and consistent, ideal dose distribution within the target volume.

  14. What is the future of brachytherapy?

    International Nuclear Information System (INIS)

    Gerbaulet, A.P.

    1999-01-01

    This review first questions the future of brachytherapy, then briefly provides a retrospective account of its development. Before any decision is made to use brachytherapy, certain preliminary considerations must be examined thoroughly. Following this cautionary introduction, an assessment of the developments in this field over the past ten years is made via the results obtained from various surveys carried out in France. These results provide information regarding the principal indications for brachytherapy, and a breakdown of the data for the different treatment centres. This examination then leads to speculation regarding the future, and how these indications for brachytherapy and associated techniques could develop for the main tumour sites. The last part of this article covers the essential factors involved in the future of brachytherapy, i.e., clinical, radiobiological, imaging, quality control, radio-physical and technological considerations. These factors are closely related and often overlap. They are also included in the context of a more general discussion on brachytherapy compared to other therapeutic methods, and on the need to adopt a common language, without which no meaningful comparison of the results or quality of treatment is possible; the necessity for specific teaching of this subject is also advocated. In conclusion, the ethical and socio-economic problems encountered in medicine are discussed in the context of brachytherapy. (author)

  15. Fulminant intravascular lymphomatosis mimicking acute haemorrhagic leukoencephalopathy.

    Science.gov (United States)

    Marino, D; Sicurelli, F; Cerase, A; Tripodi, S; Cintorino, M; Lazzi, S; Federico, A

    2012-09-15

    Intravascular lymphomatosis (IVL) is a rare non-Hodgkin's lymphoma, usually of B cell lineage, characterized by massive angiotropic growth. The clinical presentation of IVL may include changes in mental status, non-localizing neurological deficits, seizures, fever of unknown origin and skin changes. Because of its rarity and the absence of specific diagnostic procedures except for cerebral biopsy, diagnosis is often postmortem. Brain MRI usually shows non-specific abnormalities. The purpose of this case report is to increase the knowledge of clinical and neuroimaging features of IVL by describing the findings observed in a 71-year-old patient. A 71-year-old male was admitted for right hemiparesis, acute cognitive impairment and febricula. A bone marrow biopsy resulted normal. He then developed a rapid progressive impairment of his mental status and left hemisoma motor seizures. Brain CT and MRI were interpreted as consistent with acute haemorrhagic leukoencephalopathy (AHLE), including multiple areas of restricted diffusion without gadolinium enhancement and a small focal area of gadolinium enhancement in the left temporal lobe white matter. The patient died within a few days and the autopsy led to the diagnosis of IVL. IVL may present with a variety of clinical signs and symptoms, including stroke and hemiparesis. IVL may mimic AHLE at brain MRI. However, the evidence of multiple areas of restricted diffusion without gadolinium enhancement and of a small area of gadolinium enhancement could have led to the correct diagnosis. IVL should be added to the differential diagnosis of AHLE at brain MRI. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Brachytherapy in cutaneous periocular tumors

    International Nuclear Information System (INIS)

    Petriz, L.; Sole, J.M.; Cinos, C.; Gutierrez, Bayard L.; Gutierrez, Miguelez C.; Rodriguez, D.

    1996-01-01

    INTRODUCTION: Cutaneous tumors are treated surgically or with radiotherapy. Similar local control and disease-free survival are been reported using the two arms mentioned. In cutaneous periocular tumors, surgery represents an anatomical and irreversible deformity in contrast from radiation therapy that preserves anatomical sites MATERIAL AND METHODS: From June 1993 to December 1995, 6 patients with cutaneous periocular tumors (1 dermatofibrosarcoma protuberans, 1 squamous carcinoma and 4 basal cell carcinoma) have been treated with radical brachytherapy in CSUB. This tumors were located in epicantus (3 cases), superior eyelid (1 case) and free bord of inferior eyelid (2 cases). The technique used consists in interstitial application of plastic tubs and manual loading with iridium-192. Two wires were used in eyelid lesions (3 cases) and 3 wires when lesion was located in epicantus (except one patient who needed 11). Four patients received brachytherapy for primary tumors and two patients for local relapse after surgical management who previously had been treated with electron beam (42 Gy and 60 Gy with lent protection). Doses were especified to 85% isodoses (Paris system) except one case (isodose 70%) and they were 60 Gy (one patient) and 65 Gy (five patients). Lineal activity ranged from 5.21 to 7.99 cGy/h (medium 6.3 cGy/h) and duration treatment were between 30.77 h and 77.66 h. Only one patient used an ocular lent protector at time of brachytherapy. Follow-up was 2, 2, 6, 9, 10 and 27 months. RESULTS: During the treatment, all patients presented local hematoma and conjuntivitis that resolved with topical treatment. Acromy and telangiectassia have been seen in only one patient who received electron beam therapy previously. Lost of eyelashes were seen in two patients treated for parpebral lesions. None cataractas and lacrimal obstruction are reported. Five patients are live and well whitout disease and one patient died from intercurrent disease with local

  17. Characteristics of the radiochromic film Gafchromictm EBT3 model for use in brachytherapy

    International Nuclear Information System (INIS)

    Luvizotto, Jessica

    2015-01-01

    Brachytherapy is a radiotherapy treatment modality using radioactive sealed sources within walking distance of the tumor, reducing the risk of applying an unwanted dose to adjacent healthy tissues. For brachytherapy is reliable, it is necessary to establish a dosimetric practices program aimed at determining the optimal dose of radiation for this radiotherapy practice. This paper presents the application of two methodologies for the dosimetry using radiochromic films. Experimental measurements were performed with EBT3 films in phantoms consisting of homogeneous and heterogeneous material (lung, bone and soft tissue) built especially for dose measurements in brachytherapy. The processing and analysis of the resulting images of the experimental procedure were performed with ImageJ software and MATLAB. The results were evaluated from comparisons dose of experimental measurements and simulations obtained by the Monte Carlo method. (author)

  18. Guidelines for comprehensive quality assurance in brachytherapy

    International Nuclear Information System (INIS)

    Goldson, A.L.; Nibhanupudy, J.R.

    1984-01-01

    Brachytherapy treatment techniques can provide significant improvement in local control and overall survival, but only when quality assurance can be guaranteed. To establish brachytherapy quality assurance, basic requirements for three predetermined subdivisions of clinical institutions will be forwarded. These are: (1) centers having minimum requirements to provide brachytherapy, (2) intermediate centers such as regional or community hospitals, and (3) optimal centers such as university hospital and cancer centers. This presentation will highlight personnel needs, equipment requirements, academic activities, clinical experience with these systems and proposed quality assurance guidelines

  19. The Clinical Atlas of Intravascular Optical Coherence Tomography for iPad

    DEFF Research Database (Denmark)

    Radu, Maria D

    2012-01-01

    The first comprehensive educational tool devoted exclusively to intravascular OCT is now available from PCR publishing.......The first comprehensive educational tool devoted exclusively to intravascular OCT is now available from PCR publishing....

  20. Low molecular weight heparin attenuates multiple organ failure in a murine model of disseminated intravascular coagulation

    NARCIS (Netherlands)

    Slofstra, Sjoukje H.; van 't Veer, Cornelis; Buurman, Wim A.; Reitsma, Pieter H.; ten Cate, Hugo; Spek, C. Arnold

    2005-01-01

    OBJECTIVE: Bacterial sepsis causes widespread vascular inflammation that frequently leads to disseminated intravascular coagulation (DIC). Although intravascular coagulation contributes to organ failure, it is often debated whether anticoagulant therapy produces any beneficial effects in patients

  1. Construction of a anthropomorphic phantom for dose measurement in hands in brachytherapy procedures

    International Nuclear Information System (INIS)

    Papp, Cinthia M.

    2013-01-01

    The main objective of this work was to show the differences between the dose value measured by dosimeter endpoint and the values measured in different points inside the hand during brachytherapy procedures. For this, the procedures involved in the handling of sources were analyzed and the simulated using an anthropomorphic phantom hand

  2. Verification of dosimetry planning in brachytherapy in format Dicom and EUD calculation of Risk in bodies

    International Nuclear Information System (INIS)

    Garcia Hernandez, M. J.; Sendon del Rio, J. R.; Ayala Lazaro, R.; Jimenez Rojas, M. R.; Gomez Cores, S.; Polo Cezon, R.; Lopez Bote, M. A.

    2013-01-01

    This work Describes a program that automates the verification of the schedules in brachytherapy (configuration and dosimetric treatment parameters) for sources of Ir-192 (mHDR v2) and Co-60 (Co0.A86) from the plan exported in DICOM format data. (Author)

  3. Intravascular Ultrasound and its Use in Vascular Interventional Radiology

    International Nuclear Information System (INIS)

    Klepanec, A.; Vulev, I.; Vozar, M.; Balazs, T.; Madaric, J.; Holoman, M.

    2009-01-01

    Intravascular ultrasound has become in invasive vascular radiology in the last decade the important part of diagnostic and also therapeutic procedures in management of vascular diseases. The basic possibilities for the use of IVUS include diagnostic procedures in vascular pathology assessment and therapeutic indications in the field of peripheral vascular interventions (PVI). Unlike other image modalities (CT, MRI, ultrasound) IVUS enables gather unique image in r eal time r ight from the vessel lumen, what helps to add important information regarding vessel wall, plate morphology, thrombi and cross-sectional vessel area. After initial use of intravascular ultrasound in coronary circulation, using IVUS is nowadays widely extended especially in aortic diseases, carotid and renal arteries and arteries of the lower extremities. This review article summarizes possibilities of intravascular ultrasound utilization in diagnostic process and therapy from peripheral vascular diseases up to thoracoabdominal aorta diseases and our experience with this new diagnostic modality. (author)

  4. Emergency treatment by intravascular embolization in traumatic carotid cavernous fistula

    International Nuclear Information System (INIS)

    Tang Jun; Sun Zengtao; Liu Zuoqin; Liu Yanjun; Li Fengxin

    2006-01-01

    Objective: To discuss the method of intervenfional intravascular treatment in traumatic carotid cavernous fistula (TCCF) and the significance of clinical application in emergency. Methods: In 297 eases of TCCF, 36 cases were treated by interventional intravascular embolization by detachable balloon, embolization orificium or occlusion in one side of carotid artery. In the 36 cases, serious epistaxis occurred in 22 eases, cortical vein inflow in 9 cases, intracranial hemorrhage in 3 cases, aggravation of eyesight in 3 cases, and limb dysfunction in 2 cases. Results: Fistula was successfully embolized and internal carotid artery remained patent in 19 cases. Complete embolization of orificium or internal carotid artery was achieved in 17 eases. The serious epistaxias in 22 cases and intracranial hemorrhage in 3 cases stopped. Eyesight recovered in 2 eases and improved in 1 case. Limb dysfunction improved evidently in 2 cases. Conclusion: Intravascular embolization treatment is the first therapeutic choice for TCCF, especially in emergency. It is necessary, safe and effective. (authors)

  5. Monte Carlo dosimetry of the most commonly used {sup 1}92Ir high dose rate brachytherapy sources; Dosimetria Monte Carlo de las fuentes de {sup 1}92Ir de uso mas comun en braquiterapia de alta tasa de dosis

    Energy Technology Data Exchange (ETDEWEB)

    Almansa Lopez, J. F.; Torres Donaire, J.; Guerrero Alcalde, R.

    2011-07-01

    The {sup 1}92Ir sources are the most commonly used in high dose rate brachytherapy treatments. The aim of this paper is to provide the characteristic functions established by AAPM Task Group 43 (TG-43) using PENELOPE 2008.1 simulation code for the most widespread {sup 1}92Ir sources in Spain: the Gammamed Plus and Varisource 2000 sources distributed by Varian Medical Systems and the MicroSelectron source distributed by Nucletron BV. Also the new model, mHDR-v2r, has been characterized for MicroSelectron source, including some changes from the previous design, mHDR-v2. The radial dose function, anisotropy function, air-kerma strength, dose rate constant and absorbed dose rate in water tables are in good agreement with available data from other calculations. The obtained values for the dose rate constant have been 1.111 {+-} 0.002 cGy/hU for the Gammamed Plus source, 1.111{+-}0.002 cGy/hU for the MicroSelectron mHDR-v2 source, 1.112 {+-} 0,002 cGy/hU for the MicroSelectron mHDR-v2r source and 1.096 {+-} 0.002 cGy/hU for the Varisource 2000 source. Complete dosimetric results are available in http://bqseeds.sarh.es In this work, results have been obtained for the studied sources with the same calculation conditions and simulations that meet current recommendations. (Author) 28 refs.

  6. Auger Electron Therapy And Brachytherapy Tumor Treatment

    International Nuclear Information System (INIS)

    Laster, B.H.; Shani, G.

    2002-01-01

    Auger Electron Therapy (AET) is a binary approach for improving cancer radiotherapy. It involves the selective targeting of an atom to tumor cells using physiological pathway. The atom is then irradiated by a specific radiation that produces secondary radiation called Auger electrons. One of the problems associated with the clinical application of AET, is that the energy of the photons required for stimulating photoelectric absorption in most of the available high Z target atoms, is too low to achieve penetration through normal surrounding tissues to the depth of the tumor, when an external source is used. The solution is therefore the use of a brachytherapy technique. There are two other problems associated with the use of radiation as a cancer treatment. The first is the limitation on radiation dose to the normal tissue within the treatment volume. The second problem is the limitation imposed by the miniscule size of the critical target of the cell, namely the DNA (0.25% of the cell mass). The solution to the first problem can be achieved by using the brachytherapy technique. The second problem can be resolved by placing the radiation source in close position to the DNA. AET, as we apply it, provides the two solutions to the two problems. When a photon is absorbed by an electron in the K or L shell of an high Z atom, the electron is ejected from the atom, creating a vacancy in the shell. This vacancy is immediately filled with an electron from an upper shell. The energy difference between the two shells is sometimes emitted as an x-ray, however, frequently the energy is transferred to an outer shell electron that is emitted as an Auger electron. These electrons are emitted at energies of up to ∼30 keV and therefore have a very short range in the cell. They will deposit all their energy within 20-30 nm from the point of emission. i.e. all the energy is deposited in the DNA. In our work indium is used as the high Z atom

  7. SU-F-T-50: Evaluation of Monte Carlo Simulations Performance for Pediatric Brachytherapy Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Chatzipapas, C; Kagadis, G [University Patras, Rion, Ahaia (Greece); Papadimitroulas, P [BET Solutions, Athens, Attiki (Greece); Loudos, G [Technological Educational Institute of Athens, Egaleo, Attiki (Greece); Papanikolaou, N [University of Texas HSC SA, San Antonio, TX (United States)

    2016-06-15

    Purpose: Pediatric tumors are generally treated with multi-modal procedures. Brachytherapy can be used with pediatric tumors, especially given that in this patient population low toxicity on normal tissues is critical as is the suppression of the probability for late malignancies. Our goal is to validate the GATE toolkit on realistic brachytherapy applications, and evaluate brachytherapy plans on pediatrics for accurate dosimetry on sensitive and critical organs of interest. Methods: The GATE Monte Carlo (MC) toolkit was used. Two High Dose Rate (HDR) 192Ir brachytherapy sources were simulated (Nucletron mHDR-v1 and Varian VS2000), and fully validated using the AAPM and ESTRO protocols. A realistic brachytherapy plan was also simulated using the XCAT anthropomorphic computational model .The simulated data were compared to the clinical dose points. Finally, a 14 years old girl with vaginal rhabdomyosarcoma was modelled based on clinical procedures for the calculation of the absorbed dose per organ. Results: The MC simulations resulted in accurate dosimetry in terms of dose rate constant (Λ), radial dose gL(r) and anisotropy function F(r,θ) for both sources.The simulations were executed using ∼1010 number of primaries resulting in statistical uncertainties lower than 2%.The differences between the theoretical values and the simulated ones ranged from 0.01% up to 3.3%, with the largest discrepancy (6%) being observed in the dose rate constant calculation.The simulated DVH using an adult female XCAT model was also compared to a clinical one resulting in differences smaller than 5%. Finally, a realistic pediatric brachytherapy simulation was performed to evaluate the absorbed dose per organ and to calculate DVH with respect to heterogeneities of the human anatomy. Conclusion: GATE is a reliable tool for brachytherapy simulations both for source modeling and for dosimetry in anthropomorphic voxelized models. Our project aims to evaluate a variety of pediatric

  8. Remote afterloading for intracavitary and interstitial brachytherapy with californium-252

    Science.gov (United States)

    Tačev, Tačo; Grigorov, Grigor; Papírek, Tomáš; Kolařík, Vladimír.

    2004-01-01

    The authors present their design concept of remote afterloading for 252Cf brachytherapy with respect to characteristic peculiarities of 252Cf and the current worldwide development of remote afterloading devices. The afterloading device has been designed as a stationary radiator comprising three mutually interconnected units: (1) a control and drive unit, consisting of a control computer and a motor-driven Bowden system carrying the 252Cf source; (2) a source housed in a watertight, concrete vessel, which is stored in a strong room situated well beneath the patient's bed and (3) an afterloading application module installed in the irradiation room. As 252Cf is a nuclide with low specific activity, it was necessary to produce two independent devices for high dose rate intracavitary treatment and for low dose rate intestinal treatment. The sources may be moved arbitrarily during the treatment with a position accuracy of 0.5-1.0 mm within a distance of 520 cm from the source storage position in the strong room to the application position. The technical concept of the present automatic afterloading device for neutron brachytherapy represents one possible option of a range of conceivable design variants, which, while minimizing the technical and economic requirements, provides operating personnel with optimum protection and work safety, thus extending the applicability of high-LET radiation-based treatment methods in clinical practice.

  9. Extremely refractory Kawasaki disease with disseminated intravascular coagulation.

    Science.gov (United States)

    Koh, Young Kwon; Lee, Jae Hee; Park, Yeong Bong

    2017-07-01

    Disseminated intravascular coagulation is a rare complication of Kawasaki disease and appears in Kawasaki disease patients. We report a case of refractory Kawasaki disease complicated with disseminated intravascular coagulation and giant coronary aneurysm. A 5-month-old boy presented with Kawasaki disease with coagulopathy. Although the coagulopathy improved after fresh-frozen plasma and antithrombin-III administration, the fever persisted despite two rounds of intravenous immunoglobulin, along with intravenous methylprednisolone pulse therapy and infliximab administration. Despite all efforts to treatment, the patient had giant coronary aneurysms and died suddenly.

  10. 21 CFR 880.5970 - Percutaneous, implanted, long-term intravascular catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Percutaneous, implanted, long-term intravascular... and Personal Use Therapeutic Devices § 880.5970 Percutaneous, implanted, long-term intravascular catheter. (a) Identification. A percutaneous, implanted, long-term intravascular catheter is a device that...

  11. 21 CFR 880.5965 - Subcutaneous, implanted, intravascular infusion port and catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Subcutaneous, implanted, intravascular infusion... Hospital and Personal Use Therapeutic Devices § 880.5965 Subcutaneous, implanted, intravascular infusion port and catheter. (a) Identification. A subcutaneous, implanted, intravascular infusion port and...

  12. Characterization and storage of liquid wastes containing {sup 125}Iodine in the laboratory for production of brachytherapy sources - IPEN; Caracterização e armazenamento de rejeitos líquidos contendo Iodo-125 no Laboratório de Produção de fontes para braquiterapia - IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Vitória S.; Souza, Daiane C.B. de; Barbosa, Nayane K.O.; Rodrigues, Bruna T.; Nogueira, Beatriz R.; Costa, Osvaldo L. da; Zeituni, Carlos A.; Vicente, Roberto; Rostelato, Maria E.C.M., E-mail: vitoria.carvalho@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    Radioactive sources of Iodine-125 for medical applications have been developed at the Institute for Energy and Nuclear Research (IPEN) to meet the growing demand for medical applications such as brachytherapy. A dedicated laboratory is already being implemented at IPEN. Part of the processes involved in the production of sealed sources generate radioactive wastes that despite the short half-life (<100 days) have radioactive activity above the levels of exemption established by the Brazilian National Nuclear Energy Commission. Therefore, these wastes should receive appropriate treatment and storage until they reach the levels of release into the environment. This work aims to determine the volumes of the liquid wastes generated during the production stages of the sources, as well as to propose a temporary storage system for such wastes. The applied methodology consisted in determining the volumes of wastes generated in each production cell according to the manufacturing steps. After that, activities and activity concentrations were calculated for each container used for temporary storage inside the production laboratory. The total volume stored for one year in the temporary storage, as well as the rate of entry and exit of the liquid wastes were calculated according to the source production demand and the decay time of the radionuclide, respectively. The main results showed that the time required to reach sanitary sewage disposal values is within the period of operation of the facility. The total volume generated is also within the facility's temporary storage capacity.

  13. Concomitant chemoradiotherapy with high dose rate brachytherapy ...

    African Journals Online (AJOL)

    Concomitant chemoradiotherapy with high dose rate brachytherapy as a definitive treatment modality for locally advanced cervical cancer. T Refaat, A Elsaid, N Lotfy, K Kiel, W Small Jr, P Nickers, E Lartigau ...

  14. Radioactive Sources in Medicine: Impact of Additional Security Measures

    International Nuclear Information System (INIS)

    Classic, K. L.; Vetter, R. J.; Nelson, K. L.

    2004-01-01

    For many years, medical centers and hospitals have utilized appropriate security measures to prevent theft or unauthorized use of radioactive materials. Recent anxiety about orphan sources and terrorism has heightened concern about diversion of radioactive sources for purposes of constructing a radiological dispersion device. Some medical centers and hospitals may have responded by conducting threat assessments and incorporating additional measures into their security plans, but uniform recommendations or regulations have not been promulgated by regulatory agencies. The International Atomic Energy Agency drafted interim guidance for the purpose of assisting member states in deciding what security measures should be taken for various radioactive sources. The recommendations are aimed at regulators, but suppliers and users also may find the recommendations to be helpful. The purpose of this paper is to describe threat assessments and additional security actions that were taken by one large and one medium-sized medical center and the impact these measures had on operations. Both medical centers possess blood bank irradiators, low-dose-rate therapy sources, and Mo-99/Tc-99m generators that are common to many health care organizations. Other medical devices that were evaluated include high-dose-rate after loaders, intravascular brachytherapy sources, a Co-60 stereotactic surgery unit, and self-shielded irradiators used in biomedical research. This paper will discuss the impact additional security has had on practices that utilize these sources, cost of various security alternatives, and the importance of a security culture in assuring the integrity of security measures without negatively impacting beneficial use of these sources. (Author) 10 refs

  15. Evaluation of performance and quality control of high dose rate Ir-192 remote afterloading brachytherapy equipment

    International Nuclear Information System (INIS)

    Ahmed, M. A. M.

    2005-09-01

    Brachytherapy is the use of encapsulated radioactive sources to deliver a radiation dose at a short distance over a short time for treatment of malignant tumors. In Sudan, mainly in Radiation and Isotopes Center Khartoum (RICK) brachytherapy was introduced in 1989 using manual afterloading low dose rate 137 Cs for treatment of carcinoma of the cervix, but for safety reasons now it replace by high dose rate 192 Ir afterloading system (HDR) with remotely controlled device to deliver controlled radiation dose for treatment of carcinoma of cervix, esophagus and nasopharynx. This study was carried out in high dose rate 192 Ir afterloading brachytherapy equipment (Gamma Med 12i unit) located at RICK to evaluate the performance and to perform comprehensive quality control of the treatment unit with respect to three poles: safety systems, physical parameters and calibration of Ir-192 source through some quality control checks, so as to ensure that the equipment meets the safety standard. The study shows that all the safety systems which include the mechanical checks are work properly, the average of the dose rate measured at different positions from the treatment unit which represent the leakage radiation by using RDS-120 universal survey meter is less than 10μSv/h. The physical parameters which include the check of a source position accuracy by using x-OMAT ready pack film and catheter guide tube is I mm. The source strength that was obtained from the calibration procedures following the IAEA-TECDOC 1274 protocol by using HDR 1000 plus well type ionization chamber is different from the value of International Standard Laboratory by 1.5%. It was found that the brachytherapy equipment and the source used in brachytherapy meets the users requirements except some necessary requirements, so some recommendations was putted include these requirements.(Author)

  16. Long duration mild temperature hyperthermia and brachytherapy.

    Science.gov (United States)

    Armour, E P; Raaphorst, G P

    2004-03-01

    Combining long duration mild temperature hyperthermia (LDMH) and low dose-rate (LDR) brachytherapy to enhance therapeutic killing of cancer cells was proposed many years ago. The cellular and tumour research that supports this hypothesis is presented in this review. Research describing LDMH interaction with pulsed brachytherapy and high dose-rate brachytherapy using clinically relevant parameters are compared with LDMH/LDR brachytherapy. The mechanism by which LDMH sensitizes LDR has been established as the inhibition of sublethal damage repair. The molecular mechanisms have been shown to involve DNA repair enzymes, but the exact nature of these processes is still under investigation. The relative differences between LDMH interactions with human and rodent cells are presented to help in the understanding of possible roles of LDMH in clinical application. The role of LDMH in modifying tumour blood flow and its possible role in LDR sensitization of tumours is also presented. The positive aspects of LDMH-brachytherapy for clinical application are sixfold; (1) the thermal goals (temperature, time and volume) are achievable with currently available technology, (2) the hyperthermia by itself has no detectable toxic effects, (3) thermotolerance appears to play a minor if any role in radiation sensitization, (4) TER of around 2 can be expected, (5) hypoxic fraction may be decreased due to blood flow modification and (6) simultaneous chemotherapy may also be sensitized. Combined LDMH and brachytherapy is a cancer therapy that has established biological rationale and sufficient technical and clinical advancements to be appropriately applied. This modality is ripe for clinical testing.

  17. Dose optimisation in single plane interstitial brachytherapy.

    Science.gov (United States)

    Tanderup, Kari; Hellebust, Taran Paulsen; Honoré, Henriette Benedicte; Nielsen, Søren Kynde; Olsen, Dag Rune; Grau, Cai; Lindegaard, Jacob Christian

    2006-10-01

    Brachytherapy dose distributions can be optimised by modulation of source dwell times. In this study dose optimisation in single planar interstitial implants was evaluated in order to quantify the potential benefit in patients. In 14 patients, treated for recurrent rectal and cervical cancer, flexible catheters were sutured intra-operatively to the tumour bed in areas with compromised surgical margin. Both non-optimised, geometrically and graphically optimised CT -based dose plans were made. The overdose index (OI), homogeneity index (HI), conformal index (COIN), minimum target dose, and high dose volumes were evaluated. The dependence of OI, HI, and COIN on target volume and implant regularity was evaluated. In addition, 12 theoretical implant configurations were analyzed. Geometrical and graphical optimisation improved the dose plans significantly with graphical optimisation being superior. Graphically optimised dose plans showed a significant decrease of 18%+/-9% in high dose volume (pusability of these parameters for comparison of dose plans between patients. Dwell time optimisation significantly improved the dose distribution regarding homogeneity, conformity, minimum target dose, and size of high dose volumes. Graphical optimisation is fast, reproducible and superior to geometric optimisation.

  18. Dose optimisation in single plane interstitial brachytherapy

    DEFF Research Database (Denmark)

    Tanderup, Kari; Hellebust, Taran Paulsen; Honoré, Henriette Benedicte

    2006-01-01

    BACKGROUND AND PURPOSE: Brachytherapy dose distributions can be optimised       by modulation of source dwell times. In this study dose optimisation in       single planar interstitial implants was evaluated in order to quantify the       potential benefit in patients. MATERIAL AND METHODS: In 14...... patients,       treated for recurrent rectal and cervical cancer, flexible catheters were       sutured intra-operatively to the tumour bed in areas with compromised       surgical margin. Both non-optimised, geometrically and graphically       optimised CT -based dose plans were made. The overdose index...... (OI),       homogeneity index (HI), conformal index (COIN), minimum target dose, and       high dose volumes were evaluated. The dependence of OI, HI, and COIN on       target volume and implant regularity was evaluated. In addition, 12       theoretical implant configurations were analyzed. RESULTS...

  19. Mechanical scanning in intravascular ultrasound imaging: Artifacts and driving mechanisms

    NARCIS (Netherlands)

    H. ten Hoff (H.); E.J. Gussenhoven (Elma); C.M. Korbijn (Carin); F. Mastik (Frits); C.T. Lancée (Charles); N. Bom (Klaas)

    1995-01-01

    textabstractObjective: Currently, intravascular ultrasound (US) imaging catheters are developed and produced to provide a complementary diagnostic method in the treatment of blood vessel obstructive disease. Typical catheter dimensions are a diameter of 1–2.5 mm and a length of 1–1.5 m. A real-time

  20. An Axial Array for Volumetric Intravascular Ultrasound Imaging

    NARCIS (Netherlands)

    Alles, E.J.

    2012-01-01

    Intravascular ultrasound (IVUS) is a medical imaging modality aimed at imaging blood vessel walls from within the vessel. Current commercial IVUS catheters are designed to yield two-dimensional cross-sectional images perpendicular to the vessel wall. By pulling the catheter back through the artery

  1. 21 CFR 880.5440 - Intravascular administration set.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intravascular administration set. 880.5440 Section 880.5440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use...

  2. Intravascular catheter related infections in children admitted on the ...

    African Journals Online (AJOL)

    peripheral venous intravascular catheters uncoated with no antibiotic or antiseptic, was done. Social demographic characteristics, anthropometry, clinical examination including the catheter site were determined at enrollment. The children had their blood, catheter tip and hub samples taken off for culture and sensitivity as ...

  3. Disseminated intravascular coagulation in malaria: A case report ...

    African Journals Online (AJOL)

    Disseminated intravascular coagulation (DIC) is seen in <5% of patients with severe Plasmodium falciparum malaria and is more common in cerebral malaria. Here, we report the diagnosis and management of a case of severe P. falciparum malaria with DIC. Keywords: Cerebral malaria, cytokine storm, DIC, heparin ...

  4. Disseminated intravascular coagulation in meningococcal sepsis. Case 7

    NARCIS (Netherlands)

    Zeerleder, S.; Zürcher Zenklusen, R.; Hack, C. E.; Wuillemin, W. A.

    2003-01-01

    We report on a man (age: 49 years), who died from severe meningococcal sepsis with disseminated intravascular coagulation (DIC), multiple organ dysfunction syndrome and extended skin necrosis. We discuss in detail the pathophysiology of the activation of coagulation and fibrinolysis during sepsis.

  5. Intravascular catheter sepsis | Mer | South African Medical Journal

    African Journals Online (AJOL)

    Intravascular devices are an integral component of modern-day medical practice. They are used to administer intravenous fluids, medications, blood products and parenteral nutrition. In addition, they serve as a valuable monitor of the haemodynamic status of critically ill patients.

  6. Deterministic calculations of radiation doses from brachytherapy seeds

    International Nuclear Information System (INIS)

    Reis, Sergio Carneiro dos; Vasconcelos, Vanderley de; Santos, Ana Maria Matildes dos

    2009-01-01

    Brachytherapy is used for treating certain types of cancer by inserting radioactive sources into tumours. CDTN/CNEN is developing brachytherapy seeds to be used mainly in prostate cancer treatment. Dose calculations play a very significant role in the characterization of the developed seeds. The current state-of-the-art of computation dosimetry relies on Monte Carlo methods using, for instance, MCNP codes. However, deterministic calculations have some advantages, as, for example, short computer time to find solutions. This paper presents a software developed to calculate doses in a two-dimensional space surrounding the seed, using a deterministic algorithm. The analysed seeds consist of capsules similar to IMC6711 (OncoSeed), that are commercially available. The exposure rates and absorbed doses are computed using the Sievert integral and the Meisberger third order polynomial, respectively. The software also allows the isodose visualization at the surface plan. The user can choose between four different radionuclides ( 192 Ir, 198 Au, 137 Cs and 60 Co). He also have to enter as input data: the exposure rate constant; the source activity; the active length of the source; the number of segments in which the source will be divided; the total source length; the source diameter; and the actual and effective source thickness. The computed results were benchmarked against results from literature and developed software will be used to support the characterization process of the source that is being developed at CDTN. The software was implemented using Borland Delphi in Windows environment and is an alternative to Monte Carlo based codes. (author)

  7. Navigation system for interstitial brachytherapy

    International Nuclear Information System (INIS)

    Strassmann, G.; Kolotas, C.; Heyd, R.

    2000-01-01

    The purpose of the stud was to develop a computed tomography (CT) based electromagnetic navigation system for interstitial brachytherapy. This is especially designed for situations when needles have to be positioned adjacent to or within critical anatomical structures. In such instances interactive 3D visualisation of the needle positions is essential. The material consisted of a Polhemus electromagnetic 3D digitizer, a Pentium 200 MHz laptop and a voice recognition for continuous speech. In addition, we developed an external reference system constructed of Perspex which could be positioned above the tumour region and attached to the patient using a non-invasive fixation method. A specially designed needle holder and patient bed were also developed. Measurements were made on a series of phantoms in order to study the efficacy and accuracy of the navigation system. The mean navigation accuracy of positioning the 20.0 cm length metallic needles within the phantoms was in the range 2.0-4.1 mm with a maximum of 5.4 mm. This is an improvement on the accuracy of a CT-guided technique which was in the range 6.1-11.3 mm with a maximum of 19.4 mm. The mean reconstruction accuracy of the implant geometry was 3.2 mm within a non-ferromagnetic environment. We found that although the needles were metallic this did not have a significant influence. We also found for our experimental setups that the CT table and operation table non-ferromagnetic parts had no significant influence on the navigation accuracy. This navigation system will be a very useful clinical tool for interstitial brachytherapy applications, particularly when critical structures have to be avoided. It also should provide a significant improvement on our existing technique

  8. A Monte Carlo dosimetry study using Henschke applicator for cervical brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Pei-Chieh [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 101 Sec. 2, Kung Fu Road, Hsinchu 30013, Taiwan (China); Department of Radiation Oncology, Cathay General Hospital, 280 Renai Rd. Sec.4, Taipei 106, Taiwan (China); Chao, Tsi-Chian [Department of Medical Imaging and Radiological Science, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan (China); Lee, Chung-Chi [Department of Medical Imaging and Radiological Science, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan (China); Department of Radiation Oncology, Chang Gung Memorial Hospital, 5 Fu-Hsin Street, Kwei-Shan, Tao-Yuan 333, Taiwan (China); Wu, Ching-Jung [Department of Radiation Oncology, Cathay General Hospital, 280 Renai Rd. Sec.4, Taipei 106, Taiwan (China); Tung, Chuan-Jong, E-mail: cjtung@mail.cgu.edu.t [Department of Medical Imaging and Radiological Science, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan (China)

    2010-07-21

    In recent years the Henschke applicator has been widely used for gynecologic patients treated by brachytherapy in Taiwan. However, the commercial brachytherapy planning system did not properly evaluate the dose perturbation caused by the Henschke applicator. Since the European Society for Therapeutic Radiology and Oncology advised that the effect of source shielding should be incorporated into the brachytherapy planning system, it required calculation and comparison of the dose distribution around the applicator. This study used the Monte Carlo MCNP code to simulate the dose distribution in a water phantom that contained the Henschke applicator with one tandem and two ovoids. Three dwell positions of a high dose rate {sup 192}Ir source were simulated by including and excluding the applicator. The mesh tally option of the MCNP was applied to facilitate the calculation of a large number of tallies in the phantom. The voxel size effect and the charge particle equilibrium were studied by comparing the results calculated with different tally options. The calculated results showed that the brachytherapy planning system overestimated the rectal dose and that the shielding material in the applicator contributed more than 40% to the rectal dose.

  9. A Monte Carlo dosimetry study using Henschke applicator for cervical brachytherapy

    International Nuclear Information System (INIS)

    Yu, Pei-Chieh; Chao, Tsi-Chian; Lee, Chung-Chi; Wu, Ching-Jung; Tung, Chuan-Jong

    2010-01-01

    In recent years the Henschke applicator has been widely used for gynecologic patients treated by brachytherapy in Taiwan. However, the commercial brachytherapy planning system did not properly evaluate the dose perturbation caused by the Henschke applicator. Since the European Society for Therapeutic Radiology and Oncology advised that the effect of source shielding should be incorporated into the brachytherapy planning system, it required calculation and comparison of the dose distribution around the applicator. This study used the Monte Carlo MCNP code to simulate the dose distribution in a water phantom that contained the Henschke applicator with one tandem and two ovoids. Three dwell positions of a high dose rate 192 Ir source were simulated by including and excluding the applicator. The mesh tally option of the MCNP was applied to facilitate the calculation of a large number of tallies in the phantom. The voxel size effect and the charge particle equilibrium were studied by comparing the results calculated with different tally options. The calculated results showed that the brachytherapy planning system overestimated the rectal dose and that the shielding material in the applicator contributed more than 40% to the rectal dose.

  10. Remote afterloading for neutron brachytherapy using californium-252.

    Science.gov (United States)

    Tacev, Taco; Grigorov, Grigor; Papírek, Tomás; Kolarík, Vladimír

    2003-02-01

    Despite a pronounced technical process attained in radiotherapy of malignant neoplasms, no remarkable improvement in the treatment results has been achieved. The reason for this stagnation is the interaction between tumor cell and photon radiation. Tumor resistance against photon bombardment can be broken down by applying high linear energy transfer (LET) radiation-based treatment. The discovery of californium-252 ((252)Cf) nuclide, a source of gamma neutron radiation, established a precondition for using neutrons in tumor brachytherapy. The design of a remote afterloading device using (252)Cf sources remains an unsolved problem. The afterloading device has been designed as a stationary radiator which is composed of three mutually interconnected units: 1. the control and drive unit consisting of a control computer and a motor-driven bowden system carrying the (252)Cf source; 2. the source which is housed in a watertight concrete vessel-storage strong room, situated in the ground at a depth of 25 cm beneath the patient's bed; 3. the afterloading application module installed in the irradiation room. Remote afterloading allows simple, inexpensive and highly efficient radiation protection and work safety for the operating personnel. The sources may be moved arbitrarily during treatment with a position accuracy of 0.5-1.0 mm within a distance of 520 cm from the source storage position in the strong room to the application position. Both afterloading systems' unused indexer outputs are protected electronically and mechanically against any unintentional movement of the source outside the application tubes. The technologic concept of the present automatic afterloading device for neutron brachytherapy represents a possible option from the range of conceivable design variants, which - while minimizing technologic and economic requirements - provides the operating personnel with optimum protection and work safety, thus extending the applicability of high LET radiation

  11. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1996-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume --Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) --Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  12. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1997-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume -- Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) -- Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  13. Brachytherapy dose measurements in heterogeneous tissues

    Energy Technology Data Exchange (ETDEWEB)

    Paiva F, G.; Luvizotto, J.; Salles C, T.; Guimaraes A, P. C.; Dalledone S, P. de T.; Yoriyaz, H. [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Rubo, R., E-mail: gabrielpaivafonseca@gmail.com [Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, 05403-900 Sao Paulo (Brazil)

    2014-08-15

    Recently, Beau lieu et al. published an article providing guidance for Model-Based Dose Calculation Algorithms (MBDCAs), where tissue heterogeneity considerations are addressed. It is well-known that T G-43 formalism which considers only water medium is limited and significant dose differences have been found comparing both methodologies. The aim of the present work is to experimentally quantify dose values in heterogeneous medium using different dose measurement methods and techniques and compare them with those obtained with Monte Carlo simulations. Experiments have been performed using a Nucletron micro Selectron-Hdr Ir-192 brachytherapy source and a heterogeneous phantom composed by PMMA and different tissue equivalent cylinders like bone, lungs and muscle. Several dose measurements were obtained using tissue equivalent materials with height 1.8 cm and 4.3 cm positioned between the radiation source and the detectors. Radiochromic films, TLDs and MOSFET S have been used for the dose measurements. Film dosimetry has been performed using two methodologies: a) linearization for dose-response curve based on calibration curves to create a functional form that linearize s the dose response and b) 177 multichannel analysis dosimetry where the multiple color channels are analyzed allowing to address not only disturbances in the measurements caused by thickness variation in the film layer, but also, separate other external influences in the film response. All experiments have been simulated using the MCNP5 Monte Carlo radiation transport code. Comparison of experimental results are in good agreement with calculated dose values with differences less than 6% for almost all cases. (Author)

  14. Brachytherapy

    Science.gov (United States)

    ... treatment calculations. The radiation therapists are specially trained technologists who may assist in delivery of the treatments. ... a computer-controlled remote afterloading machine. X-rays , ultrasound , CT , or MRI scans may be used to ...

  15. ACPSEM brachytherapy working group recommendations for quality assurance in brachytherapy

    International Nuclear Information System (INIS)

    Dempsey, Claire; Smith, Ryan; Nyathi, Thulani; Ceylan, Abdurrahman; Howard, Lisa; Patel, Virendra; Dam, Ras; Haworth, Annette

    2013-01-01

    The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop recommendation papers for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intended to provide guidance for safe work practices and a suitable level of quality control without detailed work instructions. It is the responsibility of the medical physicist to ensure that locally available equipment and procedures are sufficiently sensitive to establish compliance to these recommendations. The recommendations are endorsed by the ROSG, have been subject to independent expert reviews and have also been approved by the ACPSEM Council. For the Australian audience, these recommendations should be read in conjunction with the Tripartite Radiation Oncology Practice Standards. This publication presents the recommendations of the ACPSEM Brachytherapy Working Group (BTWG) and has been developed in alignment with other international associations. However, these recommendations should be read in conjunction with relevant national, state or territory legislation and local requirements, which take precedence over the ACPSEM recommendation papers. It is hoped that the users of this and other ACPSEM recommendation papers will contribute to the development of future versions through the Radiation Oncology Specialty Group of the ACPSEM.

  16. Calculating of Dose Distribution in Tongue Brachytherapy by Different Radioisotopes using Monte Carlo Simulation and Comparing by Experimental Data

    Directory of Open Access Journals (Sweden)

    Banafsheh Zeinali Rafsanjani

    2011-06-01

    Full Text Available Introduction: Among different kinds of oral cavity cancers, the frequency of tongue cancer occurrence is more significant. Brachytherapy is the most common method to cure tongue cancers. Long sources are used in different techniques of tongue brachytherapy. The objective of this study is to asses the dose distribution around long sources, comparing different radioisotopes as brachytherapy sources, measuring the homogeneity of delivered dose to treatment volume and also comparing mandible dose and dose of tongue in the regions near the mandible with and without using shield. Material and Method: The Monte Carlo code MCNP4C was used for simulation. The accuracy of simulation was verified by comparing the results with experimental data. The sources like Ir-192, Cs-137, Ra-226, Au-198, In-111 and Ba-131 were simulated and the position of sources was determined by Paris system. Results: The percentage of mandible dose reduction with use of 2 mm Pb shield for the sources mentioned above were: 35.4%, 20.1%, 86.6%, 32.24%, 75.6%, and 36.8%. The tongue dose near the mandible with use of shied did not change significantly. The dose homogeneity from the most to least was obtained from these sources: Cs-137, Au-198, Ir-192, Ba-131, In-111 and Ra-226. Discussion and Conclusion: Ir-192 and Cs-137 were the best sources for tongue brachytherapy treatment but In-111 and Ra-226 were not suitable choices for tongue brachytherapy. The sources like Au-198 and Ba-131 had rather the same performance as Ir-192

  17. Characterization of TLD-100 in powders for dosimetric quality control of {sup 192} Ir sources used in brachytherapy of high dose rate; Caracterizacion de TLD-100 en polvo para control de calidad dosimetrico de fuentes de Ir{sup 192} usadas en braquiterapia de alta tasa de dosis

    Energy Technology Data Exchange (ETDEWEB)

    Loaiza C, S.P

    2007-07-01

    The Secondary Standard Dosimetric at the National Institute of Nuclear Research (ININ) calibrated a lot of powdered TLD-100 (LiF:Mg,Ti) in terms of absorbed dose to water D{sub w} for the energy of: {sup 60}Co, {sup 137C}s, X rays of 250 and 50 kVp. Later on, it is carried out an interpolation of the calibration for the energy of the {sup 192}Ir. This calibration is part of a dosimetric quality control program, to solve the problems of traceability for the measurements carried out by the users of {sup 192}Ir sources employed in the treatments of High Dose Rate Brachytherapy (HDR) at the Mexican Republic. The calibrations of the radiation beams are made with the following protocols: IAEA TRS-398 for the {sup 60}Co for D{sub w}, using a secondary standard ionization chamber PTW N30013 calibrated in D{sub w} by the National Research Council (NRC, Canada). AAPM TG-43 for D{sub w} in terms of the strength kerma Sk, calibrating this last one quantity for the {sup 137}Cs radioactive source, with a well chamber HDR 1000 PLUS traceable to the University of Wisconsin (US). AAPM TG-61 for X ray of 250 and 50 kVp for D{sub w} start to Ka using field standard a Farmer chamber PTW 30001 traceable to K for the Central Laboratory of Electric Industries (CLEI, France). The calibration curves (CC) they built for the response of the powder TLD: R{sub TLD} vs D{sub w}: For the energy of {sup 60}Co, {sup 137}Cs, X rays of 250 and 50 kVp. Fitting them with the least square method weighed by means of a polynomial of second grade that corrects the supra linearity of the response. iii. Each one of the curves was validated with a test by lack of fitting and for the Anderson Darling normality test, using the software MINITAB in both cases. iv. The sensibility factor (F{sub s}) for each energy corresponds to the slope of the CC, v. The F{sub s} for the two {sup 192}Ir sources used are interpolated: one for a Micro Selectron source and the other one a Vari Source source. Finally, a couple of

  18. Dosimetric analysis of rib interference of the CTV during interstitial brachytherapy of lung tumors.

    Science.gov (United States)

    Yang, Bo; Sun, Xiaoyang; Pang, Haowen; Shi, Xiangxiang; Tang, Tao; Zhang, Guangpeng; Chen, Renjin; Zhang, Jing; Wu, Hong; Lin, Sheng; Wen, Qinglian; Han, Yunwei; Wu, Jingbo

    2017-12-01

    In interstitial brachytherapy for lung tumors, the placement and alignment of the source needles are influenced by the ribs, which can affect the dose distribution. This study evaluated the change in dose to the target by comparing the dose between the actual interstitial brachytherapy plan (AIBP, what is deliverable due to anatomic constraints), and the virtual interstitial brachytherapy plan (VIBP, pretreatment-modified dose distribution). AIBPs and VIBPs were designed for 20 lung tumors. The VIBP was designed with uniform spacing between needles, regardless of the presence of ribs. The prescription dose was 30 Gy. The percentage of normal ipsilateral lung volume that received a dose ≥ 5 Gy (V 5 ), conformity index (COIN), incremental dose percentage (IDP) to the target, and the dose covering 95% (D 95 ) of the clinical target volume (CTV) were calculated. The V 5 of the VIBPs was significantly smaller than that of the AIBPs ( p 0.05). The regular geometric alignment of needles is important for increasing the target dose and limiting the normal lung dose in interstitial brachytherapy for thoracic tumors. Thus, we recommend that radiation oncologists attempt to achieve the regular alignment of needles during implantation.

  19. Dosimetric analysis of rib interference of the CTV during interstitial brachytherapy of lung tumors

    Directory of Open Access Journals (Sweden)

    Bo Yang

    2017-12-01

    Full Text Available Purpose : In interstitial brachytherapy for lung tumors, the placement and alignment of the source needles are influenced by the ribs, which can affect the dose distribution. This study evaluated the change in dose to the target by comparing the dose between the actual interstitial brachytherapy plan (AIBP, what is deliverable due to anatomic constraints, and the virtual interstitial brachytherapy plan (VIBP, pretreatment-modified dose distribution. Material and methods : AIBPs and VIBPs were designed for 20 lung tumors. The VIBP was designed with uniform spacing between needles, regardless of the presence of ribs. The prescription dose was 30 Gy. The percentage of normal ipsilateral lung volume that received a dose ≥ 5 Gy (V 5 , conformity index (COIN, incremental dose percentage (IDP to the target, and the dose covering 95% (D 95 of the clinical target volume (CTV were calculated. Results : The V 5 of the VIBPs was significantly smaller than that of the AIBPs (p 0.05. Conclusions : The regular geometric alignment of needles is important for increasing the target dose and limiting the normal lung dose in interstitial brachytherapy for thoracic tumors. Thus, we recommend that radiation oncologists attempt to achieve the regular alignment of needles during implantation.

  20. Study and parameters survey for iodine-125 source dosimetry to be applied in brachytherapy; Estudo e levantamentos de parametros para dosimetria de fontes de iodo-125 aplicadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo Santana de

    2011-07-01

    The use of brachytherapy technique with iodine-125 seeds to prostate cancer treatment has been used for decades with good clinical outcomes. To aim the Brazilian population necessities, IPEN-CNEN/SP developed the iodine-125 seed prototype with national technology. The objectives of this work are the development and the study of dosimetric procedures associates with the experimental acquisition of the useful parameters for the iodine-125 dosimetric characterization and to evaluate if the developed procedures, in this work, have the basic conditions to determinate the dosimetric analysis, that are fundamental for clinical procedures. The dosimeters selected for the analysis are the TLD-100 (LiF:Mg,Ti), initially these dosimeters were submitted for two selection steps to choose the dosimeters more reproducible for the dosimetric analysis. The two steps were the selection by the mass of the dosimeters and the reproducibility after four irradiation series in a Cobalt-60 irradiator (CTR-IPEN). Afterwards these steps, the dosimeters were irradiated in linear accelerator with 6 MV energy (Service of Radiotherapy - Hospital Israelita Albert Einstein) to yield the individual calibration factors to each dosimeter. After, the dosimeters were used to the irradiations with iodine-125 seed, 6711 model, (GE-Healthcare). The irradiations and others analysis with iodine-125 seeds yield the useful values for the determination of the parameters suggested by the AAPM (American Association of Physicists in Medicine): constant of dose rate, geometry function, dose radial function and anisotropy function. The results showed good agreement with the values published by the literature, for the same iodine- 125 model, this fact confirms that the realized parameters will be able to be used for the IPEN-CNEN iodine-125 seeds dosimetry and quality control. (author)

  1. Functional intravascular volume deficit in patients before surgery

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, M; Jørgensen, C C; Secher, N H

    2010-01-01

    limited data on the volume required to establish a maximal SV before the start of surgery. Therefore, we estimated the occurrence and size of the potential functional intravascular volume deficit in surgical patients. METHODS: Patients scheduled for mastectomy (n=20), open radical prostatectomy (n=20......BACKGROUND: Stroke volume (SV) maximization with a colloid infusion, referred to as individualized goal-directed therapy, improves outcome in high-risk surgery. The fraction of patients who need intravascular volume to establish a maximal SV has, however, not been evaluated, and there are only...... deficit. RESULTS: Forty-two (70%) of the patients needed volume to establish a maximal SV. For the patients needing volume, the required amount was median 200 ml (range 200-600 ml), with no significant difference between the three groups of patients. The required volume was >or=400 ml in nine patients (15...

  2. Newer techniques for intravascular and intraoperative neurointerventional procedures

    International Nuclear Information System (INIS)

    Higashida, R.T.; Halbach, V.V.; Hieshima, G.B.; Yang, P.

    1987-01-01

    A videotape demonstrating newer techniques used in intravascular and intraoperative embolization procedures will be presented. The authors discuss the use of some of the newer embolic agents, real-time digital subtraction angiography, roadmapping techniques, and the use of microcatheters and steerable micro guide wires, which has greatly facilitated neurovascullar embolization procedures and enhanced patient safety. A number of actual intraoperative and intravascular cases will be shown demonstrating treatment of vascular malformations of the brain and spinal cord, carotid cavernous sinus fistulas, aneurysms and dural arteriovenous malformations. The indications for treatment, patient selection, technical preparation and newer methodologies and approaches to complex vascular lesions of the brain and spinal cord are discussed in detail

  3. Intravascular photoacoustic tomography for characterization of atherosclerotic lipid and inflammation

    Science.gov (United States)

    Zhang, Jian; Qin, Huan; Shi, Yujiao; Yang, Sihua; Xing, Da

    2014-09-01

    Photoacoustic imaging is a fast growing imaging technology depending on its high optical resolution of optics while taking the advantage of the high penetration depth of ultrasound. In this paper, we demonstrate the new progress in the photoacoustic imaging. Atherosclerosis is characterized by a progressive build-up of lipid in the arterial wall, which is known as plaque. Histological studies demonstrate that the primary cause of acute cardiovascular events is the rupture of atherosclerotic plaques. Lipid and inflammation within the plaque are related to influence the propensity of plaques to disrupt. Photoacoustic intravascular tomography (IVPAT) holds a great advantage in providing comprehensive morphological and functional information of plaques. Lipid relative concentration maps of atherosclerotic aorta were obtained and compared with histology. Furthermore, by selectively targeting the intravascular inflammatory cytokines, IVPAT is also capable of mapping the inflamed area and determining the degree of inflammation.

  4. Acute renal failure related to oxaliplatin-induced intravascular hemolysis.

    Science.gov (United States)

    Ulusakarya, Ayhan; Misra, Srimanta; Haydar, Mazen; Habert, Hélène; Castagne, Vincent; Gumus, Yusuf; Delmas-Marsalet, Béatrice; Machover, David

    2010-12-01

    Oxaliplatin is an effective chemotherapeutic agent frequently used in the treatment of colorectal carcinoma. Rare cases of renal failure and hemolytic reactions have been reported as separate side effects of oxaliplatin. Here we present a clinical picture of immune-related intravascular hemolysis and acute tubular necrosis in a patient receiving this drug. This case suggests a mechanistic explanation of renal failure in patients treated with oxaliplatin.

  5. Front-end IC design for intravascular ultrasound imaging

    OpenAIRE

    Yamaner, Yalçın Feysel; Yamaner, Yalcin Feysel; Cenkeramaddi, Linga Reddy; Bozkurt, Ayhan

    2008-01-01

    Capacitive micromachined ultrasonic transducers(cMUT) technology is a new trend for intravascular ultrasound (IVUS) imaging. Large bandwidth, high sensitivity and compatibility to CMOS processes makes the cMUT a better choice compared to the conventional piezoelectric transducer. To exploit the merits of cMUT technology, an accurately designed front end circuit is required. The circuit functions as an output pulse driver for the generation of the acoustic signal and buffers the return echo. F...

  6. Design of low noise transimpedance amplifier for intravascular ultrasound

    KAUST Repository

    Reda, Dina

    2009-11-01

    In this paper, we study transimpedance amplifiers for capacitive sensing applications with a focus on Intravascular Ultra Sound (IVUS). We employ RF noise cancellation technique on capacitive feedback based transimpedance amplifiers. This technique eliminates the input-referred noise of TIAs completely and enhances the dynamic range of front-end electronics. Simulation results verify the proposed technique used in two different TIA topologies employing shunt-shunt feedback. ©2009 IEEE.

  7. Renal denervation by intravascular ultrasound: Preliminary in vivo study

    Science.gov (United States)

    Sinelnikov, Yegor; McClain, Steve; Zou, Yong; Smith, David; Warnking, Reinhard

    2012-10-01

    Ultrasound denervation has recently become a subject of intense research in connection with the treatment of complex medical conditions including neurological conditions, development of pain management, reproduction of skin sensation, neuropathic pain and spasticity. The objective of this study is to investigate the use of intravascular ultrasound to produce nerve damage in renal sympathetic nerves without significant injury to the renal artery. This technique may potentially be used to treat various medical conditions, such as hypertension. The study was approved by the Institutional Animal Care and Use Committee. Ultrasound was applied to renal nerves of the swine model for histopathological evaluation. Therapeutic ultrasound energy was delivered circumferentially by an intravascular catheter maneuvered into the renal arteries. Fluoroscopic imaging was conducted pre-and post-ultrasound treatment. Animals were recovered and euthanized up to 30 hours post procedure, followed by necropsy and tissue sample collection. Histopathological examination showed evidence of extensive damage to renal nerves, characterized by nuclear pyknosis, hyalinization of stroma and multifocal hemorrhages, with little or no damage to renal arteries. This study demonstrates the feasibility of intravascular ultrasound as a minimally invasive renal denervation technique. Further studies are necessary to evaluate the long-term safety and efficacy of this technique and its related clinical significance.

  8. Asian-variant intravascular lymphoma in the African race

    Directory of Open Access Journals (Sweden)

    Holly Geyer

    2012-03-01

    Full Text Available Intravascular large B-cell lymphoma (IVLBCL is an exceptionally rare form of non- Hodgkin lymphoma (NHL distinguished by the preferential growth of neoplastic cells within blood vessel lumen. Challenging to detect and deemed disseminated at diagnosis, this condition is characterized by a highly aggressive, inconspicuous course with a high mortality rate. We describe the case of a 48 year-old African-American female presenting with a two month history of low-grade fevers and malaise. Laboratory data was notable for anemia, thrombocytopenia, elevated liver function tests, and hematuria. An extensive workup for infectious, rheumatologic and malignant causes was negative. Her symptoms progressed and within two weeks, she was admitted for disseminated intravascular coagulation (DIC. Her course was complicated by diffuse pulmonary hemorrhage and ultimately, care was withdrawn. Autopsy identified widespread CD-20 positive intravascular large B-cell lymphoma with significant hepatosplenic involvement, characteristic of the Asian variant IVLBCL. This case uniquely highlights development of the Asian variant IVLBVL in a previously undescribed race. Identified by its intraluminal vascular growth pattern, IVLBCL generally spares lymphatic channels. Diagnosis and differentiation of this condition from other hematological malignancies via skin, visceral and bone marrow biopsy is imperative as anthracycline-containing chemotherapies may significantly improve clinical outcomes. This article outlines the common presentation, natural course, and treatment options of IVLBCL, along with the histopathology, immunohistochemistry, and chromosomal aberrations common to this condition.

  9. Disseminated intravascular coagulation and massive obstetric hemorrhage. Management dilemma.

    Science.gov (United States)

    Al-Nuaim, Lulu A; Mustafa, Mohamed S; Abdel Gader, Abdel Galil M

    2002-06-01

    The objective of this retrospective study is to reflect on our experience on an optimal management for major postpartum hemorrhage, which would prevent the occurrence and complications of disseminated intravascular coagulation and minimize maternal mortality and morbidity. Ten cases out of the 30,000 of total deliveries of severe obstetric hemorrhage associated with disseminated intravascular coagulation were studied. This study was carried out over a 7 year period, October 1988 through to September 1995, at the Obstetric Unit, King Khalid University Teaching Hospital, Riyadh, Kingdom of Saudi Arabia. All of the 10 women received packed red blood cells, 8 had fresh frozen plasma, and 6 received platelet transfusion. The 10 cases developed disseminated intravascular coagulation following medical and surgical management, all women needed hysterectomy, 4 subtotal, 6 total, and 5 women had relaparotomy and pelvic packing. Two had bladder injuries. There was no maternal death. An early resort to hysterectomy when conservative measures fail, will minimize maternal morbidity and mortality. In case of continuous bleeding after hysterectomy, pelvic packing proved to be effective.

  10. Extramedullary Hematopoiesis in Uterine Leiomyoma Associated with Numerous Intravascular Thrombi

    Directory of Open Access Journals (Sweden)

    Xiaoyan Cui

    2014-01-01

    Full Text Available We report a case of extramedullary hematopoiesis (EMH in uterine leiomyoma and associated numerous intravascular thrombi. A 29-year-old nulliparous female presented with heavy vaginal bleeding and a hematocrit of 22%. No bone marrow biopsy has been performed. She had a history of uterine leiomyomata and menorrhagia for a year. A transvaginal ultrasound confirmed the presence of a uterine leiomyoma. The patient was treated conservatively with oral contraceptive pills due to desire for fertility. However, she continued to have heavy vaginal bleeding and developed bilateral upper extremity deep vein thrombosis and multiple superficial vein thromboses after two months. An exploratory laparotomy with uterine myomectomy was performed. Gross examination of the specimen revealed a single nodular mass measuring 10.0×9.5×7.5 cm with a white-tan swirling cut surface. Microscopic examination revealed benign smooth muscle consistent with leiomyoma and numerous intravascular thrombi both with areas of EMH. Immunohistochemical stains confirmed the presence of all three benign lineages of hematopoietic cells. Occurrence of EMH in uterine leiomyoma and intravascular thrombi is very rare. It may be related to systemic hematopoietic stimulation due to severe chronic anemia and local presence of hematopoietic growth factors and/or cytokines.

  11. American brachytherapy society (ABS) consensus guidelines for brachytherapy of esophageal cancer

    International Nuclear Information System (INIS)

    Gaspar, Laurie E.; Nag, Subir; Herskovic, Arnold; Mantravadi, Rao; Speiser, Burton

    1997-01-01

    Introduction: There is wide variation in the indications, treatment regimens, and dosimetry for brachytherapy in the treatment of cancer of the esophagus. No guidelines for optimal therapy currently exist. Methods and Materials: Utilizing published reports and clinical experience, representatives of the Clinical Research Committee of the American Brachytherapy Society (ABS) formulated guidelines for brachytherapy in esophageal cancer. Results: Recommendations were made for brachytherapy in the definitive and palliative treatment of esophageal cancer. (A) Definitive treatment: Good candidates for brachytherapy include patients with unifocal thoracic adeno- or squamous cancers ≤ 10 cm in length, with no evidence of intra-abdominal or metastatic disease. Contraindications include tracheal or bronchial involvement, cervical esophagus location, or stenosis that cannot be bypassed. The esophageal brachytherapy applicator should have an external diameter of 6-10 mm. If 5FU-based chemotherapy and 45-50-Gy external beam are used, recommended brachytherapy is either: (i) HDR 10 Gy in two weekly fractions of 5 Gy each; or (ii) LDR 20 Gy in a single course at 0.4-1 Gy/hr. All doses are specified 1 cm from the midsource or middwell position. Brachytherapy should follow external beam radiation therapy and should not be given concurrently with chemotherapy. (B) Palliative treatment: Patients with adeno- or squamous cancers of the thoracic esophagus with distant metastases or unresectable local disease progression/recurrence after definitive radiation treatment should be considered for brachytherapy with palliative intent. After limited dose (30 Gy) EBRT, the recommended brachytherapy is either: (i) HDR 10-14 Gy in one or two fractions; or (ii) LDR 20-25 Gy in a single course at 0.4-1 Gy/hr. The need for external beam radiation in newly diagnosed patients with a life expectancy of less than 3 months is controversial. In these cases, HDR of 15-20 Gy in two to four fractions or

  12. Automation of brachytherapy planning based on RADPLAN system

    International Nuclear Information System (INIS)

    Costa, Helder Rodrigues da; Campos, Tarcisio P.R.

    2000-01-01

    RADPLAN is a software to automate the clinical planning of doses in brachytherapy managing the radionuclide source position and time. It intends to be a important tools to assist cancer treatment in the radiotherapy services. It evaluates the tridimensional isodoses for a set of radioactive sources implanted on tissue or placed inside a body cavity. RADPLAN allows visualization of virtual frames in which isodose curves overlap medical images produced in computerized tomography), X-ray and nuclear magnetic resonance equipment. In this work, the software function is explained and a hypothetic case of medical information management is presented, specifically illustrations of isodoses curves obtained for a spatial distribution of Ir 192 wires implanted in a breast. (author)

  13. The present state of brachytherapy practice in the Czech Republic

    International Nuclear Information System (INIS)

    Zackova, H.; Drabkova, A.

    1995-01-01

    In spite of the fact that radiotherapy departments in the Czech republic have been following the general European and world trends in brachytherapy techniques and that they are installing the new remote AFL systems, the reserves of radium sources are still considerably high and not all professionals carry out their applications of radioactive sources by (at least) manual AFL. In near future the attention should be paid to the diminution of the unnecessary radium reserves at that radiotherapy departments where the small number of applications is executed or where the new remote AFL systems are used. For professionals practically thorough radiation protection is assured when new remote AFL systems are used. But in this case an attention should be paid to the radiation safety of the patient because of the potential exposures when high dose rate systems would failed. The likelihood of this unwanted cases can only be decreased when Quality Assurance programs is introduced into practice

  14. Radianttrademark Liquid Radioisotope Intravascular Radiation Therapy System

    International Nuclear Information System (INIS)

    Eigler, N.; Whiting, J.; Chernomorsky, A.; Jackson, J.; Knapp, F.F. Jr.; Litvack, F.

    1998-01-01

    RADIANTtrademark is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid β-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid β-source is Rhenium-188 in the form of sodium perrhenate (NaReO 4 ), Rhenium-188 is primarily a β-emitter with a physical half-life of 17.0 hours. The maximum energy of the β-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified Championtrademark over-the-wire, and TNTtrademark rapid exchange stent delivery balloons. These balloons have thickened polyethylene walls to augment puncture resistance; dual radio-opaque markers and specially configured connectors

  15. SU-E-T-447: Electronic Brachytherapy (EBT) Treatment of Cervical Cancer - First Clinical Experience

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, D; Johnson, M; Thompson, J; Ahmad, S [University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma (United States); Chan, L; Hausen, H [Xoft Inc., San Jose, CA (United States)

    2014-06-01

    Purpose: To study the first trial patient in which an electronic brachytherapy (EBT) x-ray source is utilized for treatment of cervical cancer. Methods: During patient treatment, a miniaturized x-ray source was used in combination with a customized titanium tandem and ovoid applicator set. The semi-specialized source was modeled with formalisms outlined by AAMP Task Group 43. Multiple models were used to compensate for variable attenuation conditions as a function of source positions. Varian Brachyvision treatment planning software was utilized on CT data sets for dose calculations prior to treatment delivery. The dose was prescribed to “point A” as defined by American Brachytherapy society. Additional treatments plans were created from those clinically utilized in patient care and were recalculated for an existing Ir-192 source model. Dose volume histograms (DVH) and point dose calculations were compared between the modalities for the clinical condition present in patients treated with EBT. Results: Clinical treatment times, though longer than those typically experienced by Ir-192 users, were manageable. Instantaneous dose rates at personal positions within the treatment vault were lower than those measured during intra operative radiation therapy and breast EBT treatments. Due to lower average photon energy in EBT, dose gradients within the treatment plans were as expected steeper than those observed in Ir-192 based brachytherapy. DVH comparisons between Ir-192 and EBT treatments showed an expected decrease in the integral dose to normal tissues of interest for EBT. In comparing plans created for EBT delivery with those calculated for Ir-192, average dose values for EBT were more than 4%, 11%, and 9% lower at predefined bladder, rectum and “point B” positions, respectively. Conclusion: For the first time, we have demonstrated that the utilizing electronic brachytherapy system for tandem and ovoid based treatment of cancer of the cervix is feasible, and

  16. Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

    Directory of Open Access Journals (Sweden)

    Seyed Mohsen Hosseini Daghigh

    2012-03-01

    Full Text Available Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phantom was built in order to be inserted by various sizes of esophageal applicators. EDR2 films were placed at 33 mm from Ir-192 source and irradiated with 1.5 Gy after planning using treatment planning system for all applicators. Results The results of film dosimetry in reference point for 6, 8, 10, and 20 mm applicators were 1.54, 1.53, 1.48, and 1.50 Gy, respectively. The difference between practical and treatment planning system results was 0.023 Gy (

  17. Quality control in pulsed dose rate brachytherapy; Controle de qualite en curietherapie de debit de dose pulse

    Energy Technology Data Exchange (ETDEWEB)

    Metayer, Y.; Brunaud, C.; Peiffert, D. [Centre Alexis-Vautrin, Unite de Radiophysique, 54 - Vandoeuvre-les-Nancy (France); Meyer, P. [Centre Paul-Strauss, 67 - Strasbourg (France)

    2009-07-15

    A prospective multicenter study (P.D.R.) was leaded on pulsed dose rate brachytherapy over 2 years (2005/2006) in 20 French centres, as part of a programme entitled (Support for the innovative and expensive techniques) S.t.i.c.-P.D.R. and supported by the French ministry of health. Eight hundred and fifty patients were treated for cervix carcinoma with 2D classic or 3D innovative brachytherapy (425 in each arm). The main objectives of this study were to assess the cost of P.D.R. brachytherapy with dose optimization compared to traditional treatments, and to evaluate the complications and local control. A joint programme of quality control was established by the physicists of the different centres, concerning the software treatment planning, the source replacement, the projector and the technical parameters of the course of patient treatment. This technical note lists these controls, and their frequency. (authors)

  18. Custom-made micro applicators for high-dose-rate brachytherapy treatment of chronic psoriasis

    Directory of Open Access Journals (Sweden)

    Ivan M. Buzurovic

    2017-06-01

    Full Text Available Purpose: In this study, we present the treatment of the psoriatic nail beds of patients refractory to standard therapies using high-dose-rate (HDR brachytherapy. The custom-made micro applicators (CMMA were designed and constructed for radiation dose delivery to small curvy targets with complicated topology. The role of the HDR brachytherapy treatment was to stimulate the T cells for an increased immune response. Material and methods: The patient diagnosed with psoriatic nail beds refractory to standard therapies received monthly subunguinal injections that caused significant pain and discomfort in both hands. The clinical target was defined as the length from the fingertip to the distal interphalangeal joint. For the accurate and reproducible setup in the multi-fractional treatment delivery, the CMMAs were designed. Five needles were embedded into the dense plastic mesh and covered with 5 mm bolus material for each micro applicator. Five CMMAs were designed, resulting in the usage of 25 catheters in total. Results: The prescription dose was planned to the depth of the anterior surface of the distal phalanx, allowing for the sparing of the surrounding tissue. The total number of the active dwell positions was 145 with step size of 5 mm. The total treatment time was 115 seconds with a 7.36 Ci activity of the 192Ir source. The treatment resulted in good pain control. The patient did not require further injections to the nail bed. After this initial treatment, additional two patients with similar symptoms received HDR brachytherapy. The treatment outcome was favorable in all cases. Conclusions : The first HDR brachytherapy treatment of psoriasis of the nail bed is presented. The initial experience revealed that brachytherapy treatment was well-tolerated and resulted in adequate control of the disease. A larger cohort of patients will be required for additional conclusions related to the long-term clinical benefits.

  19. Interstitial high dose rate brachytherapy for cancer of the oral tongue

    International Nuclear Information System (INIS)

    Nishimura, Tetsuo; Nozue, Masashi; Suzuki, Kazunori; Imai, Michiko; Iijima, Mitsuharu; Kaneko, Masao

    1997-01-01

    Between October 1992 and March 1996, 34 patients with cancer of the tongue without nodal metastases underwent fractionated interstitial brachytherapy with a high dose rate (HDR) iridium remote afterloader. The types of treatment consisted of brachytherapy (BT) alone: 8 cases, BT after surgery: 3 cases, BT after systemic chemotherapy: 3 cases, BT after arterial infusion (AI): 14 cases, BT after external beam radiotherapy (ERT): 5 cases, and BT after AI+ERT: 1 case. Applicators were implanted under general anesthesia. Reference dose was estimated at point 5 mm from source. Brachytherapy was carried out in 10 fractions twice a day for 5 days. Patients received 60 Gy with BT alone, 45-55 Gy after ERT, and 50-55 Gy after chemotherapy. Local failure was found in 5 cases with T2 lesions. Recurrence occurred in 5 out of 27 cases with tumor thickness of 10 mm or less. On the other hand, there were no recurrences in 7 cases with tumor thickness of more than 10 mm. Among various types of treatment, BT following systemic chemotherapy or AI exhibited better results (local failure: 1/17) than other modalities. Lymph node metastases appeared in 11 cases. Cause specific survival was 91% at 2 years in all cases. Ulcerations of the tongue were noted in 7 in 26 evaluable cases. Although ulceration occurred in 6/13 cases treated until March 1994, the incidence decreased to 1/13 afterwards. Careful implantation and dose prescription contributed to the decrease in ulceration. Ulcerative lesions healed with conservative care within 6 months in all cases. Bone exposure occurred in 2 cases that received 60 Gy following AI for advanced diseases. HDR fractionated brachytherapy may be a workable alternative to LDR therapy for cancer of the tongue. Brachytherapy following chemotherapy can be applied to more advanced cases of the disease. (K.H.)

  20. EM-navigated catheter placement for gynecologic brachytherapy: an accuracy study

    Science.gov (United States)

    Mehrtash, Alireza; Damato, Antonio; Pernelle, Guillaume; Barber, Lauren; Farhat, Nabgha; Viswanathan, Akila; Cormack, Robert; Kapur, Tina

    2014-03-01

    Gynecologic malignancies, including cervical, endometrial, ovarian, vaginal and vulvar cancers, cause significant mortality in women worldwide. The standard care for many primary and recurrent gynecologic cancers consists of chemoradiation followed by brachytherapy. In high dose rate (HDR) brachytherapy, intracavitary applicators and /or interstitial needles are placed directly inside the cancerous tissue so as to provide catheters to deliver high doses of radiation. Although technology for the navigation of catheters and needles is well developed for procedures such as prostate biopsy, brain biopsy, and cardiac ablation, it is notably lacking for gynecologic HDR brachytherapy. Using a benchtop study that closely mimics the clinical interstitial gynecologic brachytherapy procedure, we developed a method for evaluating the accuracy of image-guided catheter placement. Future bedside translation of this technology offers the potential benefit of maximizing tumor coverage during catheter placement while avoiding damage to the adjacent organs, for example bladder, rectum and bowel. In the study, two independent experiments were performed on a phantom model to evaluate the targeting accuracy of an electromagnetic (EM) tracking system. The procedure was carried out using a laptop computer (2.1GHz Intel Core i7 computer, 8GB RAM, Windows 7 64-bit), an EM Aurora tracking system with a 1.3mm diameter 6 DOF sensor, and 6F (2 mm) brachytherapy catheters inserted through a Syed-Neblett applicator. The 3D Slicer and PLUS open source software were used to develop the system. The mean of the targeting error was less than 2.9mm, which is comparable to the targeting errors in commercial clinical navigation systems.

  1. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  2. Palladium-103 brachytherapy for prostate carcinoma

    International Nuclear Information System (INIS)

    Blasko, John C.; Grimm, Peter D.; Sylvester, John E.; Badiozamani, Kas Ray; Hoak, David; Cavanagh, William

    2000-01-01

    Purpose: A report of biochemical outcomes for patients treated with palladium-103 (Pd-103) brachytherapy over a fixed time interval. Methods and Materials: Two hundred thirty patients with clinical stage T1-T2 prostate cancer were treated with Pd-103 brachytherapy and followed with prostate-specific antigen (PSA) determinations. Kaplan-Meier estimates of biochemical failure on the basis of two consecutive elevations of PSA were utilized. Multivariate risk groups were constructed. Aggregate PSA response by time interval was assessed. Results: The overall biochemical control rate achieved at 9 years was 83.5%. Failures were local 3.0%; distant 6.1%; PSA progression only 4.3%. Significant risk factors contributing to failure were serum PSA greater than 10 ng/ml and Gleason sum of 7 or greater. Five-year biochemical control for those exhibiting neither risk factor was 94%; one risk factor, 82%; both risk factors, 65%. When all 1354 PSA determinations obtained for this cohort were considered, the patients with a proportion of PSAs ≤ 0.5 ng/ml continued to increase until at least 48 months post-therapy. These data conformed to a median PSA half-life of 96.2 days. Conclusions: Prostate brachytherapy with Pd-103 achieves a high rate of biochemical and clinical control in patients with clinically organ-confined disease. PSA response following brachytherapy with low-dose-rate isotopes is protracted

  3. Dosimetric study for characterization of a postal system of quality control in brachytherapy

    International Nuclear Information System (INIS)

    Alves, Victor Gabriel Leandro; Queiroz Filho, Pedro Pacheco de; Santos, Denison de Souza; Begalli, Marcia

    2009-01-01

    This work presents a dosimetric study of a postal system, to be developed for measurements of brachytherapy. It was projected a PMMA phantom with orifices for insertion of the high dose 192 Ir source and the T L dosemeters. The system was characterized with using of Monte Carlo simulations, using the dosimetric magnitudes defined at the T G-43 of AAPM, as function of radial dose g(f)

  4. Prostate brachytherapy in Ghana: our initial experience

    Directory of Open Access Journals (Sweden)

    James Edward Mensah

    2016-10-01

    Full Text Available Purpose: This study presents the experience of a brachytherapy team in Ghana with a focus on technology transfer and outcome. The team was initially proctored by experienced physicians from Europe and South Africa. Material and methods : A total of 90 consecutive patients underwent either brachytherapy alone or brachytherapy in combination with external beam radiotherapy for prostate carcinoma between July 2008 and February 2014 at Korle Bu Teaching Hospital, Accra, Ghana. Patients were classified as low-risk, intermediate, and high-risk according to the National Comprehensive Cancer Network (NCCN criteria. All low-risk and some intermediate risk group patients were treated with seed implantation alone. Some intermediate and all high-risk group patients received brachytherapy combined with external beam radiotherapy. Results: The median patient age was 64.0 years (range 46-78 years. The median follow-up was 58 months (range 18-74 months. Twelve patients experienced biochemical failure including one patient who had evidence of metastatic disease and died of prostate cancer. Freedom from biochemical failure rates for low, intermediate, and high-risk cases were 95.4%, 90.9%, and 70.8%, respectively. Clinical parameters predictive of biochemical outcome included: clinical stage, Gleason score, and risk group. Pre-treatment prostate specific antigen (PSA was not a statistically significant predictor of biochemical failure. Sixty-nine patients (76.6% experienced grade 1 urinary symptoms in the form of frequency, urgency, and poor stream. These symptoms were mostly self-limiting. Four patients needed catheterization for urinary retention (grade 2. One patient developed a recto urethral fistula (grade 3 following banding for hemorrhoids. Conclusions : Our results compare favorably with those reported by other institutions with more extensive experience. We believe therefore that, interstitial permanent brachytherapy can be safely and effectively

  5. Automated intraoperative calibration for prostate cancer brachytherapy

    International Nuclear Information System (INIS)

    Kuiran Chen, Thomas; Heffter, Tamas; Lasso, Andras; Pinter, Csaba; Abolmaesumi, Purang; Burdette, E. Clif; Fichtinger, Gabor

    2011-01-01

    Purpose: Prostate cancer brachytherapy relies on an accurate spatial registration between the implant needles and the TRUS image, called ''calibration''. The authors propose a new device and a fast, automatic method to calibrate the brachytherapy system in the operating room, with instant error feedback. Methods: A device was CAD-designed and precision-engineered, which mechanically couples a calibration phantom with an exact replica of the standard brachytherapy template. From real-time TRUS images acquired from the calibration device and processed by the calibration system, the coordinate transformation between the brachytherapy template and the TRUS images was computed automatically. The system instantly generated a report of the target reconstruction accuracy based on the current calibration outcome. Results: Four types of validation tests were conducted. First, 50 independent, real-time calibration trials yielded an average of 0.57 ± 0.13 mm line reconstruction error (LRE) relative to ground truth. Second, the averaged LRE was 0.37 ± 0.25 mm relative to ground truth in tests with six different commercial TRUS scanners operating at similar imaging settings. Furthermore, testing with five different commercial stepper systems yielded an average of 0.29 ± 0.16 mm LRE relative to ground truth. Finally, the system achieved an average of 0.56 ± 0.27 mm target registration error (TRE) relative to ground truth in needle insertion tests through the template in a water tank. Conclusions: The proposed automatic, intraoperative calibration system for prostate cancer brachytherapy has achieved high accuracy, precision, and robustness.

  6. Optimum plastic scintillator and optical fiber combination for brachytherapy dosimetry

    International Nuclear Information System (INIS)

    Arnfield, Mark R.; Gaballa, Hani E.; Zwicker, Robert D.; Islam, Quazi; Schmidt-Ullrich, Rupert

    1995-01-01

    Purpose/Objective: There have been several recent reports using plastic scintillators to measure dose in photon and electron beams. External beam measurements agreed well with standard ion chamber dosimetry. This was implemented by using two identical, parallel optical fibers with a small piece of plastic scintillator attached to one. We have constructed a similar device for application to brachytherapy. Brachytherapy dosimetry is a more difficult problem than external beam because of high dose gradients and widely ranging photon energies. Based on detailed spectral measurements, we have designed a dosimeter specifically to meet the unique, stringent needs of brachytherapy. Materials and Methods: The work consisted of two stages. In the first stage, we measured the optical spectra emitted by commercial plastic scintillators and silica core optical fibers in the presence of a 10 Curie iridium 192 HDR source. In the second stage, the spectral information was used to select an optimum combination of scintillator and fiber which were incorporated in the dosimeter. Equipment for the spectral measurements included a 0.1 meter monochromator with a sensitive photomultiplier (PMT) with flat response across the visible. The resolution of spectral scans was 4 nm. The dosimeter was constructed with a 1mm x 3mm piece of plastic scintillator bonded with optical cement to a 0.6 mm diameter silica core optical fiber. A second, identical optical fiber running alongside the first, with no scintillator attached, was used for background subtraction. Two PMTs with high sensitivity in the visible were used at the fiber distal ends. There was a space for an optical filter between the fiber and the PMTs, whose purpose is described below. The PMTs were connected to a differential pair whose output was transferred to a current source for measurement by a standard electrometer. Results: The scintillation spectra of six different types of silica core optical fibers in the presence of the

  7. Image Guided Cervical Brachytherapy: 2014 Survey of the American Brachytherapy Society.

    Science.gov (United States)

    Grover, Surbhi; Harkenrider, Matthew M; Cho, Linda P; Erickson, Beth; Small, Christina; Small, William; Viswanathan, Akila N

    2016-03-01

    To provide an update of the 2007 American brachytherapy survey on image-based brachytherapy, which showed that in the setting of treatment planning for gynecologic brachytherapy, although computed tomography (CT) was often used for treatment planning, most brachytherapists used point A for dose specification. A 45-question electronic survey on cervical cancer brachytherapy practice patterns was sent to all American Brachytherapy Society members and additional radiation oncologists and physicists based in the United States between January and September 2014. Responses from the 2007 survey and the present survey were compared using the χ(2) test. There were 370 respondents. Of those, only respondents, not in training, who treat more than 1 cervical cancer patient per year and practice in the United States, were included in the analysis (219). For dose specification to the target (cervix and tumor), 95% always use CT, and 34% always use MRI. However, 46% use point A only for dose specification to the target. There was a lot of variation in parameters used for dose evaluation of target volume and normal tissues. Compared with the 2007 survey, use of MRI has increased from 2% to 34% (Pimage-based brachytherapy has increased in the United States since the 2007 survey, there is room for further growth, particularly with the use of MRI. This increase may be in part due to educational initiatives. However, there is still significant heterogeneity in brachytherapy practice in the United States, and future efforts should be geared toward standardizing treatment. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Image Guided Cervical Brachytherapy: 2014 Survey of the American Brachytherapy Society

    Energy Technology Data Exchange (ETDEWEB)

    Grover, Surbhi, E-mail: Surbhi.grover@uphs.upenn.edu [Department of Radiation Oncology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Harkenrider, Matthew M. [Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Chicago, Illinois (United States); Cho, Linda P. [Department of Radiation Oncology, Brigham & Women' s Hospital/Dana-Farber Cancer Institute, Boston, Massachusetts (United States); Erickson, Beth [Department Radiation Oncology, Froedtert Hospital and Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Small, Christina [Department of Public Health Sciences, Stritch School of Medicine, Loyola University Chicago, Chicago, Illinois (United States); Small, William [Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Chicago, Illinois (United States); Viswanathan, Akila N. [Department of Radiation Oncology, Brigham & Women' s Hospital/Dana-Farber Cancer Institute, Boston, Massachusetts (United States)

    2016-03-01

    Purpose: To provide an update of the 2007 American brachytherapy survey on image-based brachytherapy, which showed that in the setting of treatment planning for gynecologic brachytherapy, although computed tomography (CT) was often used for treatment planning, most brachytherapists used point A for dose specification. Methods and Materials: A 45-question electronic survey on cervical cancer brachytherapy practice patterns was sent to all American Brachytherapy Society members and additional radiation oncologists and physicists based in the United States between January and September 2014. Responses from the 2007 survey and the present survey were compared using the χ{sup 2} test. Results: There were 370 respondents. Of those, only respondents, not in training, who treat more than 1 cervical cancer patient per year and practice in the United States, were included in the analysis (219). For dose specification to the target (cervix and tumor), 95% always use CT, and 34% always use MRI. However, 46% use point A only for dose specification to the target. There was a lot of variation in parameters used for dose evaluation of target volume and normal tissues. Compared with the 2007 survey, use of MRI has increased from 2% to 34% (P<.0001) for dose specification to the target. Use of volume-based dose delineation to the target has increased from 14% to 52% (P<.0001). Conclusion: Although use of image-based brachytherapy has increased in the United States since the 2007 survey, there is room for further growth, particularly with the use of MRI. This increase may be in part due to educational initiatives. However, there is still significant heterogeneity in brachytherapy practice in the United States, and future efforts should be geared toward standardizing treatment.

  9. Verification of the calculation program for brachytherapy planning system of high dose rate (PLATO); Programa de verificacion del calculo para un sistema de planificacion de braquiterapia de alta tasa de dosis (PLATO)

    Energy Technology Data Exchange (ETDEWEB)

    Almansa, J.; Alaman, C.; Perez-Alija, J.; Herrero, C.; Real, R. del; Ososrio, J. L.

    2011-07-01

    In our treatments are performed brachytherapy high dose rate since 2007. The procedures performed include gynecological intracavitary treatment and interstitial. The treatments are performed with a source of Ir-192 activity between 5 and 10 Ci such that small variations in treatment times can cause damage to the patient. In addition the Royal Decree 1566/1998 on Quality Criteria in radiotherapy establishes the need to verify the monitor units or treatment time in radiotherapy and brachytherapy. All this justifies the existence of a redundant system for brachytherapy dose calculation that can reveal any abnormality is present.

  10. Phantom's construction for dose measurement in brachytherapy

    International Nuclear Information System (INIS)

    Tri Harjanto; Hidayat Joko Puspito; Joko Triyanto

    2009-01-01

    In nuclear medicine, dose rate validation is the key for a successful process in therapy and diagnose of any deases. Therefore, the brachytherapy equipment being designed and constructed is to be validated its dose rate received by the radiated object. A phantom for such validation purpose is designed and constructed as a correct as if on site geometrical position of sources. The design of phantom consists of seven layers of flexi glass plates: 10 mm thick, 105 mm wide, and 280 mm length. All the plates are to be holed according to the size of the applicator to be used. Every surface of the flexi glass layers is grooved 1 mm wide, 1 mm depth, and 10 mm distance between the groove. The applicator inside the phantom is positioned at a certain reference for measurement. Every TLD installed has a fix position toward the reference coordinate and has an index number. By this system of phantom, the isodose system can be plotted. (author)

  11. Computerized planning and dosimetry for brachytherapy in carcinomas cervix

    International Nuclear Information System (INIS)

    Kizilbash, N.A.; Jabeen, K.; Hussain, R.

    1996-01-01

    A project on the use of computerize planning and dosimetry for brachytherapy in carcinoma of cervix was started at NORI (Nuclear Medicine, Oncology and Radiotherapy Institute, Islamabad) in september 1990. A total number of 182 patients were included in the study over a period of three years. The treatment of all these patients was done by external radiation as well as the intracavitary therapy. Planning and dosimetry was done according to ICRU 38 recommendations. 70 patients were planned with two computers TP-II (Dr. J. Cunningham's software) and PC based system (Dr. Kallinger's software, BTI system). From the results of the two computers TP-II and PC, it can be seen that the difference in a absorbed dose for all recommended points in not going to harm the patient. The dose to the bladder and the rectum in our studies is quite low because of the low activity in the ovoid sources. (author)

  12. Cost effective method of manual afterloading 192Ir brachytherapy

    International Nuclear Information System (INIS)

    Mohan, R.; Ravishankar, B.; Muralkrishna, B.V.

    2001-01-01

    Full text: In radiotherapy, brachytherapy mode of treatment has equal importance like the external beam radiotherapy. In our hospital we have manual afterloading 137 Cs kit supplied by BRIT for intracavitary treatment of carcinoma cervix and vaginal cases. In July 1999, we also started afterloading 192 Ir brachytherapy. For a hospital like ours, where funds are minimal, it is impossible to procure remote afterloading brachytherapy unit, which is very costly. So we have developed the cost-effective 192 Ir manual brachytherapy and so far we have done 60 cases which include intraluminal and interstitial cases

  13. BrachyTPS -Interactive point kernel code package for brachytherapy treatment planning of gynaecological cancers

    International Nuclear Information System (INIS)

    Thilagam, L.; Subbaiah, K.V.

    2008-01-01

    Brachytherapy treatment planning systems (TPS) are always recommended to account for the effect of tissue, applicator and shielding material heterogeneities exist in Intracavitary brachytherapy (ICBT) applicators. Most of the commercially available brachytherapy TPS softwares estimate the absorbed dose at a point, only taking care of the contributions of individual sources and the source distribution, neglecting the dose perturbations arising from the applicator design and construction. So the doses estimated by them are not much accurate under realistic clinical conditions. In this regard, interactive point kernel rode (BrachyTPS) has been developed to perform independent dose calculations by taking into account the effect of these heterogeneities, using two regions build up factors, proposed by Kalos. As primary input data, the code takes patients' planning data including the source specifications, dwell positions, dwell times and it computes the doses at reference points by dose point kernel formalisms, with multi-layer shield build-up factors accounting for the contributions from scattered radiation. In addition to performing dose distribution calculations, this code package is capable of displaying an isodose distribution curve into the patient anatomy images. The primary aim of this study is to validate the developed point kernel code integrated with treatment planning systems against the other tools which are available in the market. In the present work, three brachytherapy applicators commonly used in the treatment of uterine cervical carcinoma, Board of Radiation Isotope and Technology (BRIT) made low dose rate (LDR) applicator, Fletcher Green type LDR applicator and Fletcher Williamson high dose rate (HDR) applicator were studied to test the accuracy of the software

  14. Retinal and choroidal intravascular spectral-domain optical coherence tomography

    DEFF Research Database (Denmark)

    Willerslev, Anne; Li, Xiao Qiang; Cordtz, Peter

    2014-01-01

    on longitudinal scans and a figure-of-eight configuration on cross-sectional scans. Intravascular reflectivity decreased with increasingly oblique angles of observation and was absent when blood flow was parallel to the line of sight. The high blood flow in the choroidal vessels in healthy subjects and the low......-OCT profile of the blood column in retinal vessels with normal blood flow. Both structure and total reflectivity faded when blood flow was lower or higher than normal or at oblique angles to the line of sight. In conclusion, SD-OCT scans of the vessels in the posterior pole of the eye may assist the clinical...

  15. Why Have So Many Intravascular Glucose Monitoring Devices Failed?

    Science.gov (United States)

    Smith, John L; Rice, Mark J

    2015-07-01

    Secondary to the inherent limitations of both point-of-care and central laboratory glucose technologies, continuous glucose measurement has recently enjoyed a high level of investment. Because of the perceived advantages by some of measuring in the intravascular space compared to the subcutaneous tissue, a number of technologies have been developed. In this review, we evaluate nine systems that have shown promise, although only one of these has been cleared for sale in the United States. The detection methodology, regulatory status, technical issues, and company circumstance surrounding each technology are examined. © 2015 Diabetes Technology Society.

  16. Recurring extracranial internal carotid artery vasospasm detected by intravascular ultrasound.

    Science.gov (United States)

    Dembo, Tomohisa; Tanahashi, Norio

    2012-01-01

    A 24-year-old woman presented with headache and left-sided focal signs following multiple episodes of right monocular visual impairment. Magnetic resonance angiography revealed a decreased vascular image intensity due to a suspicious stenosis in the right internal carotid artery (ICA). The stenosis was not demonstrated on duplex sonography as it was beyond the field of view of the investigation. Intravascular ultrasound (IVUS) revealed that the outer vessel diameter was significantly reduced during stenosis, supporting the presence of vasospasm. Idiopathic recurrent extracranial ICA vasospasm was diagnosed. Recurrent vasospasms of extracranial ICA may be a distinct entity that can cause ischemic stroke.

  17. Assessing mechanical properties with intravascular or endoscopic optical coherence tomography

    Science.gov (United States)

    Lamouche, G.; Azarnoush, H.; Vergnole, S.; Pazos, V.; Bisaillon, C.-E.; Debergue, P.; Boulet, B.; Diraddo, R.

    2011-03-01

    We explore the potential of intravascular or endoscopic optical coherence tomography (OCT) to extract relevant mechanical properties of a tissue deformed by an inflating balloon. Tubular OCT phantoms with different mechanical properties are fabricated. The phantoms are deformed by an inflating balloon, and the deformation is monitored with OCT. A quantitative description of the phantom deformation is obtained by segmenting the OCT images. Two strategies to extract the mechanical properties from this quantitative data are presented: by comparing to a finite-element simulation and by performing a mechanical analysis.

  18. CT use for nasopharingeal molds realization in endocavitary brachytherapy

    International Nuclear Information System (INIS)

    Lopez, J. Torrecilla; Crispin, V.; Chust, M.; Guinot, J.; Arribas, L.; Mengual, J.; Carrasco, P.; Miragall, E.; Hernandez, A.; Guardino, C.; Carrascosa, M.; Cardenal, R.; Casana, M.; Prats, C.

    1996-01-01

    Purpose: We present the following procedure for the making of individual molds with dental silicone for endocavitary brachytherapy of nasopharingeal cancer aided by CT scan. Procedure: Head immobilization during the realization of nasopharynx CT. Planification of treatment using these CT images, to determine the optimum position of radioactive sources. Printing on paper CT images with the nasopharynx contoured walls and the radioactive sources position. Realization of the mold in plastiline with the aid of the cuts of printer paper cut out with the nasopharynx form. Obtaining of the negative of the mold of plastiline by means of the use of alginate. Placement of two number 20 rectal rigid catheters with metal malleable bars inside them, in order to give them an adequate form in relation to the previous carried out planning. Filling in of alginato negative, where rectal catheters were placed, with Provil MCD Bayer Dental, a silicone based material for precision impression. We recommend to crossing the catheters' end with a number 2 silk thread to secure the catheter. An end of the silk thread is left outside the mold in order to help the extraction at the end of application. We advise to carry out a neuroleptic anaesthesia for its insertion, for the purpose of achieving a soft palate suitable relaxation. It makes the insertion easier. Repeat CT with the mold and phantoms in position to know a definitive dose distribution calculation. Conclusion: This method avoids the necessity of general anaesthesia in the realization of individual molds of nasopharyx for endocavitary brachytherapy and it improves the implant dosimetry

  19. CT-guided brachytherapy. A novel percutaneous technique for interstitial ablation of liver malignancies; CT-gesteuerte Brachytherapie. Eine neue perkutane Technik zur interstitiellen Ablation von Lebermetastasen

    Energy Technology Data Exchange (ETDEWEB)

    Ricke, J.; Wust, P.; Stohlmann, A.; Beck, A.; Cho, C.H.; Pech, M.; Wieners, G.; Spors, B.; Werk, M.; Rosner, C.; Haenninen, E.L.; Felix, R. [Klinik fuer Strahlenheilkunde, Charite Virchow-Klinikum, Humboldt-Univ. zu Berlin (Germany)

    2004-05-01

    Purpose: to assess safety and efficacy of CT-guided brachytherapy of liver malignancies. Patients and methods: 21 patients with 21 liver malignancies (19 metastases, two primary liver tumors) were treated with interstitial CT-guided brachytherapy applying a {sup 192}Ir source. In all patients, the use of image-guided thermal tumor ablation such as by radiofrequency or laser-induced thermotherapy (LITT) was impeded either by tumor size {>=} 5 cm in seven, adjacent portal or hepatic vein in ten, or adjacent bile duct bifurcation in four patients. Dosimetry was performed using three-dimensional CT data sets acquired after CT-guided positioning of the brachytherapy catheters. Results: the mean tumor diameter was 4.6 cm (2.5-11 cm). The mean minimal tumor dose inside the tumor margin amounted to 17 Gy (12-20 Gy). The proportion of the liver parenchyma exposed to > 5 gy was 18% (5-39%) of total liver parenchyma minus tumor volume. Nausea and vomiting were observed in six patients after brachytherapy (28%). One patient demonstrated obstructive jaundice due to tumor edema after irradiation of a metastasis adjacent to the bile duct bifurcation. We commonly encountered asymptomatic increases of liver enzymes. Local control rates after 6 and 12 months were 87% and 70%, respectively. Conclusion: CT-guided brachytherapy is safe and effective. This technique displays broader indications compared to image-guided thermal ablation by radiofrequency or LITT with respect to tumor size or localization. (orig.) [German] Ziel: Analyse der Sicherheit und Effektivitaet CT-gesteuerter Brachytherapie zur Ablation von Lebermalignomen. Patienten und Methodik: 21 Patienten mit 21 Lebermalignomen (19 Metastasen, zwei primaere Lebermalignome) wurden mit perkutaner, CT-gesteuerter interstitieller Brachytherapie mit {sup 192}Ir behandelt. Alle Patienten wiesen Umstaende auf, die eine bildgefuehrte thermische Ablation mit Radiofrequenz oder laserinduzierter Thermotherapie (LITT) einschraenkten

  20. Neutron therapy coupling brachytherapy and boron neutron capture therapy (BNCT) techniques

    International Nuclear Information System (INIS)

    Chaves, Iara Ferreira.

    1994-12-01

    In the present dissertation, neutron radiation techniques applied into organs of the human body are investigated as oncologic radiation therapy. The proposal treatment consists on connecting two distinct techniques: Boron Neutron Capture Therapy (BNCT) and irradiation by discrete sources of neutrons, through the brachytherapy conception. Biological and radio-dosimetrical aspects of the two techniques are considered. Nuclear aspects are discussed, presenting the nuclear reactions occurred in tumoral region, and describing the forms of evaluating the dose curves. Methods for estimating radiation transmission are reviewed through the solution of the neutron transport equation, Monte Carlo methodology, and simplified analytical calculation based on diffusion equation and numerical integration. The last is computational developed and presented as a quickly way to neutron transport evaluation in homogeneous medium. The computational evaluation of the doses for distinct hypothetical situations is presented, applying the coupled techniques BNTC and brachytherapy as an possible oncologic treatment. (author). 78 refs., 61 figs., 21 tabs

  1. The Preliminary Prototype of Medium Dose Rate Brachytherapy Equipment

    International Nuclear Information System (INIS)

    A- Satmoko; T- Harjanto; IM- Putra; Kristiyanti

    2013-01-01

    A preliminary prototype of a brachytherapy equipment has been constructed. The work started by developing conceptual design, followed by basic design and detailed design. In the conceptual design, design requirements are stated. In the basic design, technical specifications for main components are determined. In detailed design, general drawings are discussed. The prototype consists of three main systems: a mechanical system, an instrumentation system, and a safety system. The mechanical system assures the movement mechanism of the isotope source position beginning from the standby position until the applicators. It consists of three main modules: a position handling module, a container module, and a channel distribution module. The position handling module serves to move the isotope source position. As shielding, the second module is to store the source when the equipment is in standby position. The prototype provides 12 output channels. The channel selection is performed by the third module. The instrumentation system controls the movement of source position by handling motor operations. It consists of several modules. A micro controller module serves as a control center whose task includes both controlling motors and communicating with computer. A motor module serves to handle motors. 10 sensors, including their signal conditionings, are introduced to read the environment conditions of the equipment. LED's are used to display these conditions. In order to facilitate the operators’ duty, communication via RS232 is provided. The brachytherapy equipment can therefore be operated by using computer. Interface software is developed using C# language. To complete both mechanical and instrumentation systems performance, a safety system is developed to make sure that the safety for operator and patients from receiving excessive radiation. An interlock system is introduced to guard against abnormal conditions. In the worst case, a manual intervention by the operator is

  2. The Preliminary Prototype of Medium Dose Rate Brachytherapy Equipment

    Directory of Open Access Journals (Sweden)

    A. Satmoko

    2013-08-01

    Full Text Available A preliminary prototype of a brachytherapy equipment has been constructed. The work started by developing conceptual design, followed by basic design and detailed design. In the conceptual design, design requirements are stated. In the basic design, technical specifications for main components are determined. In detailed design, general drawings are discussed. The prototype consists of three main systems: a mechanical system, an instrumentation system, and a safety system. The mechanical system assures the movement mechanism of the isotope source position beginning from the standby position until the applicators. It consists of three main modules: a position handling module, a container module, and a channel distribution module. The position handling module serves to move the isotope source position. As shielding, the second module is to store the source when the equipment is in standby position. The prototype provides 12 output channels. The channel selection is performed by the third module. The instrumentation system controls the movement of source position by handling motor operations. It consists of several modules. A microcontroller module serves as a control center whose task includes both controlling motors and communicating with computer. A motor module serves to handle motors. 10 sensors, including their signal conditionings, are introduced to read the environment conditions of the equipment. LEDs are used to display these conditions. In order to facilitate the operators’ duty, communication via RS232 is provided. The brachytherapy equipment can therefore be operated by using computer. Interface software is developed using C# language. To complete both mechanical and instrumentation systems performance, a safety system is developed to make sure that the safety for operator and patients from receiving excessive radiation. An interlock system is introduced to guard against abnormal conditions. In the worst case, a manual intervention

  3. EVALUATION OF BRACHYTHERAPY FACILITY SHIELDING STATUS IN KOREA OBTAINED FROM RADIATION SAFETY REPORTS

    Directory of Open Access Journals (Sweden)

    MI HYUN KEUM

    2013-10-01

    Full Text Available Thirty-eight radiation safety reports for brachytherapy equipment were evaluated to determine the current status of brachytherapy units in Korea and to assess how radiation oncology departments in Korea complete radiation safety reports. The following data was collected: radiation safety report publication year, brachytherapy unit manufacturer, type and activity of the source that was used, affiliation of the drafter, exposure rate constant, the treatment time used to calculate workload and the HVL values used to calculate shielding design goal values. A significant number of the reports (47.4% included the personal information of the drafter. The treatment time estimates varied widely from 12 to 2,400 min/week. There was acceptable variation in the exposure rate constant values (ranging between 0.469 and 0.592 (R-m2/Ci·hr, as well as in the HVLs of concrete, steel and lead for Iridium-192 sources that were used to calculate shielding design goal values. There is a need for standard guidelines for completing radiation safety reports that realistically reflect the current clinical situation of radiation oncology departments in Korea. The present study may be useful for formulating these guidelines.

  4. Intravascular stenting (IVaS) method for fingertip replantation.

    Science.gov (United States)

    Narushima, Mitsunaga; Mihara, Makoto; Koshima, Isao; Gonda, Koichi; Takuya, Iida; Kato, Harunosuke; Nakanishi, Kenji; Yamamoto, Yusuke; Araki, Jun; Abe, Hiroaki; Mundinger, Gerhard S; Kikuchi, Kazuki; Uehara, Eri

    2009-01-01

    Remarkable progress has been made in microsurgery. However, fingertip replantation following amputation has not gained much popularity because of its technical difficulty. We have developed the intravascular stenting (IVaS) method, in which a nylon monofilament is placed inside the vessel lumen to act as a temporary stent, facilitating anastomosis completion. This report describes 7 fingertip replantations using the IVaS method. Intravascular stent size varied from 4-0 to 6-0 (0.199-0.07 mm diameter). There were no cases in which the back wall of a vessel became inadvertently caught in the anastomosis. The overall survival rate for distal digital replants was 85% (6/7 replants). It is very difficult to evenly anastomose vessels of differing diameter, especially on a supermicrosurgical scale. In this respect, the IVaS method plays a role in stably anchoring the 2 vessel ends, allowing for the even spacing of suture knots, even in vessels of different caliber. Because of its ease of use and exactitude, many surgeons may be able to use the IVaS method to reliably complete small anastomoses in fingertip replantations.

  5. High speed intravascular photoacoustic imaging of atherosclerotic arteries (Conference Presentation)

    Science.gov (United States)

    Piao, Zhonglie; Ma, Teng; Qu, Yueqiao; Li, Jiawen; Yu, Mingyue; He, Youmin; Shung, K. Kirk; Zhou, Qifa; Kim, Chang-Seok; Chen, Zhongping

    2016-02-01

    Cardiovascular disease is the leading cause of death in the industrialized nations. Accurate quantification of both the morphology and composition of lipid-rich vulnerable atherosclerotic plaque are essential for early detection and optimal treatment in clinics. In previous works, intravascular photoacoustic (IVPA) imaging for detection of lipid-rich plaque within coronary artery walls has been demonstrated in ex vivo, but the imaging speed is still limited. In order to increase the imaging speed, a high repetition rate laser is needed. In this work, we present a high speed integrated IVPA/US imaging system with a 500 Hz optical parametric oscillator laser at 1725 nm. A miniature catheter with 1.0 mm outer diameter was designed with a 200 μm multimode fiber and an ultrasound transducer with 45 MHz center frequency. The fiber was polished at 38 degree and enclosed in a glass capillary for total internal reflection. An optical/electrical rotary junction and pull-back mechanism was applied for rotating and linearly scanning the catheter to obtain three-dimensional imaging. Atherosclerotic rabbit abdominal aorta was imaged as two frame/second at 1725 nm. Furthermore, by wide tuning range of the laser wavelength from 1680 nm to 1770 nm, spectroscopic photoacoustic analysis of lipid-mimicking phantom and an human atherosclerotic artery was performed ex vivo. The results demonstrated that the developed IVPA/US imaging system is capable for high speed intravascular imaging for plaque detection.

  6. Late adverse reactions to intravascular iodinated contrast media

    International Nuclear Information System (INIS)

    Webb, Judith A.W.; Stacul, Fulvio; Thomsen, Henrik S.; Morcos, Sameh K.

    2003-01-01

    Late adverse reactions to intravascular iodinated contrast media are defined as reactions occurring 1 h to 1 week after contrast medium injection. They have received increasing interest over the past decade, but their prevalence remains uncertain and their pathophysiology is not fully understood. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and to issue guidelines. An extensive literature search was carried out and summarized in a report. Based on the available information, simple guidelines have been drawn up. The report and guidelines were discussed at the 8th European Symposium on Urogenital Radiology in Genoa. Late adverse reactions after intravascular iodinated contrast medium include symptoms such as nausea, vomiting, headache, itching, skin rash, musculoskeletal pain, and fever. A significant proportion of these reactions is unrelated to the contrast medium; however, allergy-like skin reactions are well-documented side effects of contrast media with an incidence of approximately 2%. Late reactions appear to be commoner after non-ionic dimers. The majority of late skin reactions after contrast medium exposure are probably T-cell-mediated allergic reactions. Patients at increased risk of late skin reactions are those with a history of previous contrast medium reaction and those on interleukin-2 treatment. Most skin reactions are self-limiting and resolve within a week. Management is symptomatic and similar to the management of other drug-induced skin reactions. (orig.)

  7. An Implantable Intravascular Pressure Sensor for a Ventricular Assist Device

    Directory of Open Access Journals (Sweden)

    Luigi Brancato

    2016-08-01

    Full Text Available The aim of this study is to investigate the intravascular application of a micro-electro-mechanical system (MEMS pressure sensor to directly measure the hemodynamic characteristics of a ventricular assist device (VAD. A bio- and hemo-compatible packaging strategy is implemented, based on a ceramic thick film process. A commercial sub-millimeter piezoresistive sensor is attached to an alumina substrate, and a double coating of polydimethylsiloxane (PDMS and parylene-C is applied. The final size of the packaged device is 2.6 mm by 3.6 mm by 1.8 mm. A prototype electronic circuit for conditioning and read-out of the pressure signal is developed, satisfying the VAD-specific requirements of low power consumption (less than 14.5 mW in continuous mode and small form factor. The packaged sensor has been submitted to extensive in vitro tests. The device displayed a temperature-independent sensitivity (12 μ V/V/mmHg and good in vitro stability when exposed to the continuous flow of saline solution (less than 0.05 mmHg/day drift after 50 h. During in vivo validation, the transducer has been successfully used to record the arterial pressure waveform of a female sheep. A small, intravascular sensor to continuously register the blood pressure at the inflow and the outflow of a VAD is developed and successfully validated in vivo.

  8. CT-Based Brachytherapy Treatment Planning using Monte Carlo Simulation Aided by an Interface Software

    Directory of Open Access Journals (Sweden)

    Vahid Moslemi

    2011-03-01

    Full Text Available Introduction: In brachytherapy, radioactive sources are placed close to the tumor, therefore, small changes in their positions can cause large changes in the dose distribution. This emphasizes the need for computerized treatment planning. The usual method for treatment planning of cervix brachytherapy uses conventional radiographs in the Manchester system. Nowadays, because of their advantages in locating the source positions and the surrounding tissues, CT and MRI images are replacing conventional radiographs. In this study, we used CT images in Monte Carlo based dose calculation for brachytherapy treatment planning, using an interface software to create the geometry file required in the MCNP code. The aim of using the interface software is to facilitate and speed up the geometry set-up for simulations based on the patient’s anatomy. This paper examines the feasibility of this method in cervix brachytherapy and assesses its accuracy and speed. Material and Methods: For dosimetric measurements regarding the treatment plan, a pelvic phantom was made from polyethylene in which the treatment applicators could be placed. For simulations using CT images, the phantom was scanned at 120 kVp. Using an interface software written in MATLAB, the CT images were converted into MCNP input file and the simulation was then performed. Results: Using the interface software, preparation time for the simulations of the applicator and surrounding structures was approximately 3 minutes; the corresponding time needed in the conventional MCNP geometry entry being approximately 1 hour. The discrepancy in the simulated and measured doses to point A was 1.7% of the prescribed dose.  The corresponding dose differences between the two methods in rectum and bladder were 3.0% and 3.7% of the prescribed dose, respectively. Comparing the results of simulation using the interface software with those of simulation using the standard MCNP geometry entry showed a less than 1

  9. A review of the clinical experience in pulsed dose rate brachytherapy

    NARCIS (Netherlands)

    Balgobind, Brian V.; Koedooder, Kees; Ordoñez Zúñiga, Diego; Dávila Fajardo, Raquel; Rasch, Coen R. N.; Pieters, Bradley R.

    2015-01-01

    Pulsed dose rate (PDR) brachytherapy is a treatment modality that combines physical advantages of high dose rate (HDR) brachytherapy with the radiobiological advantages of low dose rate brachytherapy. The aim of this review was to describe the effective clinical use of PDR brachytherapy worldwide in

  10. Sexual function after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Galbreath, R.W.; Merrick, G.S.; Butler, W.M.; Stipetich, R.L.; Abel, L.J.; Lief, J.H.

    2001-01-01

    Purpose: To determine the incidence of potency preservation following permanent prostate brachytherapy and to evaluate the effect of multiple clinical and treatment parameters on penile erectile function. Materials and Methods: 425 patients underwent permanent prostate brachytherapy from April 1995 to October 1999. 209 patients who were potent prior to brachytherapy and currently not receiving hormonal manipulation were mailed an International Index of Erectile Function (IIEF) questionnaire with a pre-addressed stamped envelope. 180 patients completed and returned the questionnaire. Median patient follow-up was 39 months (range 18-74 months). Pre-implant erectile function was assigned using a three-tiered scoring system (2 = erections always or nearly always sufficient for vaginal penetration; 1 = erections sufficient for vaginal penetration but considered suboptimal; 0 = the inability to obtain erections and/or erections inadequate for vaginal penetration). Post-implant potency was defined as an IIEF score >11. Clinical parameters evaluated for sexual function included patient age, clinical T stage, elapsed time since implantation, hypertension, diabetes mellitus, and tobacco consumption. Evaluated treatment parameters included the utilization of neoadjuvant hormonal manipulation and the choice of isotope. The efficacy of sildenafil citrate in brachytherapy induced erectile dysfunction (ED) was also evaluated. Results: A pre-treatment erectile function score of 2 and 1 were assigned to 126 and 54 patients respectively. With 6 year follow up, 39% of patients maintained potency following prostate brachytherapy with a plateau on the curve. Post-implant preservation of potency (IIEF>11) correlated with pre-implant erectile function (50% versus 14% for pre-implant scores of 2 and 1 respectively, p≤0.0001), patient age (56%, 38%, and 23% for patients <60 years of age, 60-69 years of age, and ≥70 years of age respectively, p=0.012) and a history of diabetes mellitus

  11. Development of a brachytherapy audit checklist tool.

    Science.gov (United States)

    Prisciandaro, Joann; Hadley, Scott; Jolly, Shruti; Lee, Choonik; Roberson, Peter; Roberts, Donald; Ritter, Timothy

    2015-01-01

    To develop a brachytherapy audit checklist that could be used to prepare for Nuclear Regulatory Commission or agreement state inspections, to aid in readiness for a practice accreditation visit, or to be used as an annual internal audit tool. Six board-certified medical physicists and one radiation oncologist conducted a thorough review of brachytherapy-related literature and practice guidelines published by professional organizations and federal regulations. The team members worked at two facilities that are part of a large, academic health care center. Checklist items were given a score based on their judged importance. Four clinical sites performed an audit of their program using the checklist. The sites were asked to score each item based on a defined severity scale for their noncompliance, and final audit scores were tallied by summing the products of importance score and severity score for each item. The final audit checklist, which is available online, contains 83 items. The audit scores from the beta sites ranged from 17 to 71 (out of 690) and identified a total of 7-16 noncompliance items. The total time to conduct the audit ranged from 1.5 to 5 hours. A comprehensive audit checklist was developed which can be implemented by any facility that wishes to perform a program audit in support of their own brachytherapy program. The checklist is designed to allow users to identify areas of noncompliance and to prioritize how these items are addressed to minimize deviations from nationally-recognized standards. Copyright © 2015 American Brachytherapy Society. All rights reserved.

  12. Current status of high dose rate brachytherapy in cervical cancer in Korea and optimal treatment schedule

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Seung Jae [College of Medicine, Sungkyunkwan Univ., Seoul (Korea, Republic of)

    1998-12-01

    Brachytherapy is an essential part of radiotherapy for uterine cervical cancer. The low dose rate (LDR) regimen has been the major technique of intracavitary therapy for cervical cancer. However, there has been an expansion in the last 20 years of high dose rate (HDR) machines using Ir-192 sources. Since 1979, HDR brachytherapy has been used for the treatment of uterine cervical cancer in Korea. The number of institutions employing HDR has been increasing, while the number of low dose rate system has been constant. In 1995, there was a total 27 HDR brachytherapy units installed and 1258 cases of patients with cervical cancer were treated with HDR. Most common regimens of HDR brachytherapy are total dose of 30-39 Gy at point A with 10-13 fractions in three fractions per week, 24-32 Gy with 6-8 fractions in two fractions per week, and 30-35 Gy with 6-7 fractions in two fractions per week. The average fractionation regimen of HDR brachytherapy is about 8 fractions of 4. 1 Gy each to point A. In Korea, treatment results for HDR brachytherapy are comparable with the LDR series and appears to be a safe and effective alternative to LDR therapy for the treatment of cervical carcinoma. Studies from the major centers report the five-year survival rate of cervical cancer as, 78-86% for Stage I, 68-85% for stage II, and 38-56% for Stage III. World-wide questionnaire study and Japanese questionnaire survey of multiple institutions showed no survival difference in any stages and dose-rate effect ratio (HDR/LDR) was calculated to be 0.54 to 0.58. However, the optimum treatment doses and fractionation schemes appropriate to generate clinical results comparable to conventional LDR schemes have yet to be standardized. In conclusion, HDR intracavitary radiotherapy is increasingly practiced in Korea and an effective treatment modality for cervical cancer. To determine the optimum radiotherapy dose and fractionation schedule, a nation-wide prospective study is necessary in Korea. In

  13. Three dimensional implementation of anisotropy corrected fast fourier transform dose calculation around brachytherapy seeds

    International Nuclear Information System (INIS)

    Kyeremeh, P.O.

    2011-01-01

    Current-available brachytherapy dose computation algorithms ignore heterogeneities such as tissue-air interfaces, shielded gynaecological colpostats, and tissue-composition variations in source implants despite dose computation errors as large as 40%. A convolution kernel, which takes into consideration anisotropy of the dose distribution around a brachytherapy source, and to compute dose in the presence of tissue and applicator heterogeneities, has been established. Resulting from the convolution kernel are functions with polynomial and exponential terms. the solution to the convolution integral was represented by the Fast Fourier transform. The Fast Fourier transform has shown enough potency in accounting for errors due to these heterogeneities and the versatility of this Fast Fourier transform is evident from its capability of switching in between fields. Thus successful procedures in external beam could be adopted in brachytherapy to a yield similar effect. A dose deposition kernel was developed for a 64x64x64 matrix size with wrap around ordering and convoluted with the distribution of the sources in 3D. With MatLab's inverse Fast Fourier transform, dose rate distribution for a given array of interstitial sources, typical of brachytherapy was calculated. The shape of the dose rate distribution peaks appeared comparable with the output expected from computerized treatment planning systems for brachytherapy. Subsequently, the study confirmed the speed and accuracy of dose computation using the FFT convolution as well juxtaposed. Although, dose rate peaks from both the FFT convolution and the TPS(TG43) did not compare quantitatively, which was mainly due to the TPS(TG43) initiation computations from the origin (0,0,0) unlike the FFT convolution which uses sampling points; N=1,2,3..., there is a strong basis for establishing parity since the dose rate peaks compared qualitatively. With both modes compared, the discrepancies in the dose rates ranged between 3.6% to

  14. MO-A-BRC-00: TG167: Clinical Recommendations for Innovative Brachytherapy Devices and Applicators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used to evaluate innovative radiotherapy devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining equivalence of the innovative device to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of an innovative brachytherapy device or application is a critical part in which physicists are actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative products or applications and includes evaluation of 1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, 2) risks and benefits from regulatory and safety perspectives, and 3) resource assessment and preparedness. Further, calibration methods should be traceable to a primary standards dosimetry laboratory such as NIST in the U.S. or to other primary standards dosimetry laboratory located elsewhere. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the ADCLs is encouraged before a source is introduced into widespread routine clinical use. The AAPM and GEC-ESTRO have developed guidelines for the safe and consistent application of brachytherapy using innovative brachytherapy devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of

  15. MO-A-BRC-00: TG167: Clinical Recommendations for Innovative Brachytherapy Devices and Applicators

    International Nuclear Information System (INIS)

    2016-01-01

    Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used to evaluate innovative radiotherapy devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining equivalence of the innovative device to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of an innovative brachytherapy device or application is a critical part in which physicists are actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative products or applications and includes evaluation of 1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, 2) risks and benefits from regulatory and safety perspectives, and 3) resource assessment and preparedness. Further, calibration methods should be traceable to a primary standards dosimetry laboratory such as NIST in the U.S. or to other primary standards dosimetry laboratory located elsewhere. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the ADCLs is encouraged before a source is introduced into widespread routine clinical use. The AAPM and GEC-ESTRO have developed guidelines for the safe and consistent application of brachytherapy using innovative brachytherapy devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of

  16. Brachytherapy treatment with high dose rate

    International Nuclear Information System (INIS)

    Santana Rodriguez, Sergio Marcelino; Rodriguez Rodriguez, Lissi Lisbet; Ciscal Chiclana, Onelio Alberto

    2009-01-01

    Retrospectively analyze results and prognostic factors of cervical cancer patients treated with radio concomitant cisplatin-based chemotherapy, radiation therapy combined modality. Methods: From January 2003 to December 2007, 198 patients with invasive cervical cancer were treated at the Oncology Department of Hospital Robau Celestino Hernandez (brachytherapy performed at INOR). The most common age group was 31 to 40 years. The histology in squamous cell carcinoma accounted for 84.3% of cases. The treatment consisted of external pelvic irradiation and vaginal brachytherapy, high dose rate. Concomitant chemotherapy consisted of cisplatin 40 mg/m2 weekly with a maximum of 70 mg for 5 weeks. Results: 66.2% of patients completed 5 cycles of chemotherapy. The median overall survival was 39 months, overall survival, disease-free survival and survival free of locoregional recurrence at 5 years of 78%, 76% and 78.6% respectively .. We found that clinical stage, histological type (adenocarcinoma worst outcome) were statistically related to level of response. Conclusions: Treatment with external pelvic radiation, brachytherapy and concurrent weekly cisplatin in patients with stage IIIB cervical cancer is feasible in the Chilean public health system, well tolerated and results comparable to international literature. (Author)

  17. Radioactive seed immobilization techniques for interstitial brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yan, K.; Podder, T.; Buzurovic, I.; Hu, Y.; Dicker, A.; Valicenti, R.; Yu, Y. [Thomas Jefferson University, Department of Radiation Oncology, Philadelphia, PA (United States); Messing, E. [University of Rochester, Departments of Urology and Surgery, Rochester, NY (United States); Rubens, D. [University of Rochester, Departments of Imaging Science and Surgery, Rochester, NY (United States); Sarkar, N. [Vanderbilt University, Department of Mechanical Engineering, Nashville, TN (United States); Ng, W. [Nangyang Technical University, School of Mechanical and Aerospace Engineering, Singapore (Singapore)

    2008-06-15

    In prostate brachytherapy, seeds can detach from their deposited sites and move locally in the pelvis or migrate to distant sites including the pulmonary and cardiac regions. Undesirable consequences of seed migration include inadequate dose coverage of the prostate and tissue irradiation effects at the site of migration. Thus, it is clinically important to develop seed immobilization techniques. We first analyze the possible causes for seed movement, and propose three potential techniques for seed immobilization: (1) surgical glue, (2) laser coagulation and (3) diathermy coagulation. The feasibility of each method is explored. Experiments were carried out using fresh bovine livers to investigate the efficacy of seed immobilization using surgical glue. Results have shown that the surgical glue can effectively immobilize the seeds. Evaluation of the radiation dose distribution revealed that the non-immobilized seed movement would change the planned isodose distribution considerably; while by using surgical glue method to immobilize the seeds, the changes were negligible. Prostate brachytherapy seed immobilization is necessary and three alternative mechanisms are promising for addressing this issue. Experiments for exploring the efficacy of the other two proposed methods are ongoing. Devices compatible with the brachytherapy procedure will be designed in future. (orig.)

  18. Brachytherapy in treatment of vaginal cancer

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2016-01-01

    Full Text Available Characteristics of diagnosis and treatment of different types of primary vaginal cancer are highlighted, the role and place of brachytherapy as independent method or combined treatment modality for this pathology is shown in the review. Epidemiological data on incidence of vaginal cancer in Russia are represented, presumptive mechanisms for development of the disease, risk factors, histological types, features of the course, clinical presentation, diagnostic algorithm are described. Treatment methods for primary vaginal cancer according to world standards such as surgery, radiotherapy and systemic drug therapy are covered. Specifics of radiological methods of treatment (low-dose rate and high-dose rate brachytherapy, including the combination with external beam radiotherapy according to the stage of the disease, are shown in details. The results of several large foreign clinical trials for efficiency of different methods of radiotherapy are discussed. The combination of brachytherapy on primary tumor with external radiation therapy to the lymph nodes was confirmed to be the most effective modality. The conclusion on opportunities of different methods of radiotherapy in treatment of vaginal cancer was made.

  19. The use of nomograms in LDR-HDR prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Ma Carmen Pujades

    2011-09-01

    Full Text Available Purpose: The common use of nomograms in Low Dose Rate (LDR permanent prostate brachytherapy (BT allowsto estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for eachclinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adaptedto High Dose Rate (HDR. This work sets nomograms for LDR and HDR prostate-BT implants, which are applied tothree different institutions that use different implant techniques. Material and methods: Patients treated throughout 2010 till April 2011 were considered for this study. This examplewas chosen to be the representative of the latest implant techniques and to ensure consistency in the planning. A sufficientnumber of cases for both BT modalities, prescription dose and different work methodology (depending on theinstitution were taken into account. The specific nomograms were built using the correlation between the prostatevo lume and some characteristic parameters of each BT modality, such as the source Air Kerma Strength, numberof implanted seeds in LDR or total radiation time in HDR. Results: For each institution and BT modality, nomograms normalized to the prescribed dose were obtained andfitted to a linear function. The parameters of the adjustment show a good agreement between data and the fitting.It should be noted that for each institution these linear function parameters are different, indicating that each centreshould construct its own nomograms. Conclusions: Nomograms for LDR and HDR prostate brachytherapy are simple quality assurance tools, specific foreach institution. Nevertheless, their use should be complementary to the necessary independent verification.

  20. Two years results of electronic brachytherapy for basal cell carcinoma

    Directory of Open Access Journals (Sweden)

    Rosa Ballester-Sánchez

    2017-06-01

    Full Text Available Purpose: The use of radiation therapy (RT for non-melanoma skin cancer (NMSC has been changing throughout the last century. Over the last decades, the use of radiotherapy has surged with the development of new techniques, applicators, and devices. In recent years, electronic brachytherapy (eBT devices that use small x-ray sources have been introduced as alternative to radionuclide dependence. Nowadays, several devices have been incorporated, with a few series reported, and with a short follow-up, due to the recent introduction of these systems. The purpose of this work is to describe the clinical results of our series after two years follow-up with a specific eBT system. Material and methods: This is a prospective single-center, non-randomized pilot study, to assess clinical results of electronic brachytherapy in basal cell carcinoma using the Esteya® system. In 2014, 40 patients with 60 lesions were treated. Patient follow-up on a regular basis was performed for a period of two years. Results: Twenty-six patients with 44 lesions achieved two years follow-up. A complete response was documented in 95.5% of cases. Toxicity was mild (G1 or G2 in all cases, caused by erythema, erosion, or alopecia. Cosmesis was excellent in 88.6% of cases, and good in the rest. Change in pigmentation was the most frequent cosmetic alteration. Conclusions : This work is special, since the equipment’s treatment voltage was 69.5 kV, and this is the first prospective study with long term follow-up with Esteya®. These preliminary report show excellent results with less toxicity and excellent cosmesis. While surgery has been the treatment of choice, certain patients might benefit from eBT treatment. These are elderly patients with comorbidities or undergoing anticoagulant treatment as well as those who simply refuse surgery or might have other contraindications.

  1. Two years results of electronic brachytherapy for basal cell carcinoma.

    Science.gov (United States)

    Ballester-Sánchez, Rosa; Pons-Llanas, Olga; Candela-Juan, Cristian; de Unamuno-Bustos, Blanca; Celada-Alvarez, Francisco Javier; Tormo-Mico, Alejandro; Perez-Calatayud, Jose; Botella-Estrada, Rafael

    2017-06-01

    The use of radiation therapy (RT) for non-melanoma skin cancer (NMSC) has been changing throughout the last century. Over the last decades, the use of radiotherapy has surged with the development of new techniques, applicators, and devices. In recent years, electronic brachytherapy (eBT) devices that use small x-ray sources have been introduced as alternative to radionuclide dependence. Nowadays, several devices have been incorporated, with a few series reported, and with a short follow-up, due to the recent introduction of these systems. The purpose of this work is to describe the clinical results of our series after two years follow-up with a specific eBT system. This is a prospective single-center, non-randomized pilot study, to assess clinical results of electronic brachytherapy in basal cell carcinoma using the Esteya ® system. In 2014, 40 patients with 60 lesions were treated. Patient follow-up on a regular basis was performed for a period of two years. Twenty-six patients with 44 lesions achieved two years follow-up. A complete response was documented in 95.5% of cases. Toxicity was mild (G1 or G2) in all cases, caused by erythema, erosion, or alopecia. Cosmesis was excellent in 88.6% of cases, and good in the rest. Change in pigmentation was the most frequent cosmetic alteration. This work is special, since the equipment's treatment voltage was 69.5 kV, and this is the first prospective study with long term follow-up with Esteya ® . These preliminary report show excellent results with less toxicity and excellent cosmesis. While surgery has been the treatment of choice, certain patients might benefit from eBT treatment. These are elderly patients with comorbidities or undergoing anticoagulant treatment as well as those who simply refuse surgery or might have other contraindications.

  2. Determination of air kerma standard of high dose rate {sup 192}Ir brachytherapy source; Determinacao da taxa de kerma no ar de referencia para {sup 192}Ir de alta taxa de dose para braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Pires, E.J.; Alves, C.F.E.; Leite, S.P.; Magalhaes, L.A.G.; David, M.G.; Almeida, C.E. de, E-mail: cfealves@gmail.com [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Lab. de Ciencias Radiologicas; Di Prinzio, R. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    This paper presents the methodology developed by the Laboratorio de Ciencias Radiologicas and presently in use for determining of the air kerma standard of {sup 192}Ir high dose rate sources to calibrate well-type chambers. Uncertainty analysis involving the measurements procedure are presented. (author)

  3. Monte Carlo simulation with PENELOPE and parameters of the TG-43 for 125 select Seed source used in brachytherapy Nucletron; Simulacion Monte Carlo con PENELOPE y parametros del TG-43 para la fuente de {sup 1}25I selectSeed de Neutron usada en braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Juan-Senablre, X. J.; Porras, I.; Lallena, A. M.

    2011-07-01

    Simulating the power of Nucletron brachytherapy techniques select Seed Monte Carlo (MC) with the code-PENELOPE [1]. In particular, we seek the parameters in the formalism proposed by the AAPM in TG-43 report [2]. We propose new settings for accurate results.

  4. Brachytherapy in the treatment of cervical cancer: a review

    Directory of Open Access Journals (Sweden)

    Banerjee R

    2014-05-01

    Full Text Available Robyn Banerjee,1 Mitchell Kamrava21Department of Radiation Oncology, Tom Baker Cancer Centre, Calgary, Alberta, Canada; 2Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA, USAAbstract: Dramatic advances have been made in brachytherapy for cervical cancer. Radiation treatment planning has evolved from two-dimensional to three-dimensional, incorporating magnetic resonance imaging and/or computed tomography into the treatment paradigm. This allows for better delineation and coverage of the tumor, as well as improved avoidance of surrounding organs. Consequently, advanced brachytherapy can achieve very high rates of local control with a reduction in morbidity, compared with historic approaches. This review provides an overview of state-of-the-art gynecologic brachytherapy, with a focus on recent advances and their implications for women with cervical cancer.Keywords: cervical cancer, brachytherapy, image-guided brachytherapy

  5. Accelerated partial breast irradiation utilizing balloon brachytherapy techniques

    International Nuclear Information System (INIS)

    Strauss, Jonathan B.; Dickler, Adam

    2009-01-01

    To overcome the barriers to BCT, methods of PBI in the setting of breast conservation have been explored. The method of PBI with the longest published follow-up is multi-catheter interstitial brachytherapy. Balloon-based brachytherapy with the MammoSite brachytherapy applicator was designed to simplify the brachytherapy procedure for PBI, enhance the reproducibility of the dosimetry, and improve patient comfort. The rates of local recurrence following PBI with the MammoSite applicator have been low, but there are few published reports and follow-up has been relatively short. The cosmetic outcomes and toxicity of MammoSite PBI are comparable to those seen after multicatheter-based PBI. Additional methods of balloon brachytherapy, including Xoft and SenoRx Contura have been developed. Finally, long-term follow-up after PBI is important for the welfare of individual patients and in order to establish the efficacy, late toxicity and cosmetic outcomes of this technique.

  6. Penile brachytherapy: Results for 49 patients

    International Nuclear Information System (INIS)

    Crook, Juanita M.; Jezioranski, John; Grimard, Laval; Esche, Bernd; Pond, G.

    2005-01-01

    Purpose: To report results for 49 men with squamous cell carcinoma (SCC) of the penis treated with primary penile interstitial brachytherapy at one of two institutions: the Ottawa Regional Cancer Center, Ottawa, and the Princess Margaret Hospital, Toronto, Ontario, Canada. Methods and Materials: From September 1989 to September 2003, 49 men (mean age, 58 years; range, 22-93 years) had brachytherapy for penile SCC. Fifty-one percent of tumors were T1, 33% T2, and 8% T3; 4% were in situ and 4% Tx. Grade was well differentiated in 31%, moderate in 45%, and poor in 2%; grade was unspecified for 20%. One tumor was verrucous. All tumors in Toronto had pulsed dose rate (PDR) brachytherapy (n = 23), whereas those in Ottawa had either Iridium wire (n 22) or seeds (n = 4). Four patients had a single plane implant with a plastic tube technique, and all others had a volume implant with predrilled acrylic templates and two or three parallel planes of needles (median, six needles). Mean needle spacing was 13.5 mm (range, 10-18 mm), mean dose rate was 65 cGy/h (range, 33-160 cGy/h), and mean duration was 98.8 h (range, 36-188 h). Dose rates for PDR brachytherapy were 50-61.2 cGy/h, with no correction in total dose, which was 60 Gy in all cases. Results: Median follow-up was 33.4 months (range, 4-140 months). At 5 years, actuarial overall survival was 78.3% and cause-specific survival 90.0%. Four men died of penile cancer, and 6 died of other causes with no evidence of recurrence. The cumulative incidence rate for never having experienced any type of failure at 5 years was 64.4% and for local failure was 85.3%. All 5 patients with local failure were successfully salvaged by surgery; 2 other men required penectomy for necrosis. The soft tissue necrosis rate was 16% and the urethral stenosis rate 12%. Of 8 men with regional failure, 5 were salvaged by lymph node dissection with or without external radiation. All 4 men with distant failure died of disease. Of 49 men, 42 had an intact

  7. Compensation of spectral artifacts in dual-modality intravascular optical coherence tomography and near-infrared spectroscopy (Conference Presentation)

    Science.gov (United States)

    Fard, Ali M.; Gardecki, Joseph A.; Ughi, Giovanni J.; Hyun, Chulho; Tearney, Guillermo J.

    2016-02-01

    Intravascular optical coherence tomography (OCT) is a high-resolution catheter-based imaging method that provides three-dimensional microscopic images of coronary artery in vivo, facilitating coronary artery disease treatment decisions based on detailed morphology. Near-infrared spectroscopy (NIRS) has proven to be a powerful tool for identification of lipid-rich plaques inside the coronary walls. We have recently demonstrated a dual-modality intravascular imaging technology that integrates OCT and NIRS into one imaging catheter using a two-fiber arrangement and a custom-made dual-channel fiber rotary junction. It therefore enables simultaneous acquisition of microstructural and composition information at 100 frames/second for improved diagnosis of coronary lesions. The dual-modality OCT-NIRS system employs a single wavelength-swept light source for both OCT and NIRS modalities. It subsequently uses a high-speed photoreceiver to detect the NIRS spectrum in the time domain. Although use of one light source greatly simplifies the system configuration, such light source exhibits pulse-to-pulse wavelength and intensity variation due to mechanical scanning of the wavelength. This can be in particular problematic for NIRS modality and sacrifices the reliability of the acquired spectra. In order to address this challenge, here we developed a robust data acquisition and processing method that compensates for the spectral variations of the wavelength-swept light source. The proposed method extracts the properties of the light source, i.e., variation period and amplitude from a reference spectrum and subsequently calibrates the NIRS datasets. We have applied this method on datasets obtained from cadaver human coronary arteries using a polygon-scanning (1230-1350nm) OCT system, operating at 100,000 sweeps per second. The results suggest that our algorithm accurately and robustly compensates the spectral variations and visualizes the dual-modality OCT-NIRS images. These

  8. Erectile function after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Galbreath, Robert W.; Stipetich, Robin L.; Abel, Laurie J.; Lief, Jonathan H.

    2002-01-01

    Purpose: To determine the incidence of potency preservation after permanent prostate brachytherapy using a validated patient-administered questionnaire and to evaluate the effect of multiple clinical and treatment parameters on penile erectile function. Methods and Materials: Four hundred twenty-five patients underwent permanent prostate brachytherapy from April 1995 to October 1999. Two hundred nine patients who were potent before brachytherapy and who at the time of the survey were not receiving hormonal therapy were mailed the specific erectile questions of the International Index of Erectile Function (IIEF) questionnaire with a self-addressed stamped envelope. The questionnaire consisted of 5 questions, with a maximal score of 25. Of the 209 patients, 181 (87%) completed and returned the questionnaire. The mean and median follow-up was 40.4±14.9 and 40.6 months, respectively (range 19-75). Preimplant erectile function was assigned using a three-tiered scoring system (2 = erections always or nearly always sufficient for vaginal penetration; 1 = erections sufficient for vaginal penetration but considered suboptimal; 0 = the inability to obtain erections and/or erections inadequate for vaginal penetration). Postimplant potency was defined as an IIEF score ≥11. The clinical parameters evaluated for erectile function included patient age, preimplant potency, clinical T-stage, pretreatment prostate-specific antigen level, Gleason score, elapsed time after implantation, hypertension, diabetes mellitus, and tobacco consumption. Treatment parameters included radiation dose to the prostate gland, use of hormonal manipulation, use of supplemental external beam radiotherapy (EBRT), choice of isotope, prostate volume, and planning volume. The efficacy of sildenafil citrate in brachytherapy-induced erectile dysfunction (ED) was also evaluated. Results: Pretreatment erectile function scores of 2 and 1 were assigned to 125 and 56 patients, respectively. With a 6-year follow

  9. SU-E-T-564: Multi-Helix Rotating Shield Brachytherapy for Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Dadkhah, H; Wu, X [University of Iowa, Iowa City, IA (United States); Flynn, R; Kim, Y [University of Iowa Hospitals and Clinics, Iowa City, IA (United States)

    2015-06-15

    Purpose: To present a novel and practical brachytherapy technique, called multi-helix rotating shield brachytherapy (H-RSBT), for the precise positioning of a partial shield in a curved applicator. H-RSBT enables RSBT delivery using only translational motion of the radiation source/shield combination. H-RSBT overcomes the challenges associated with previously proposed RSBT approaches based on a serial (S-RSBT) step-and-shoot delivery technique, which required independent translational and rotational motion. Methods: A Fletcher-type applicator, compatible with the combination of a Xoft Axxent™ electronic brachytherapy source and a 0.5 mm thick tungsten shield, is proposed. The wall of the applicator contains six evenly-spaced helical keyways that rigidly define the emission direction of the shield as a function of depth. The shield contains three protruding keys and is attached to the source such that it rotates freely. S-RSBT and H-RSBT treatment plans with 180° and 45° azimuthal emission angles were generated for five cervical cancer patients representative of a wide range of high-risk clinical target volume (HR-CTV) shapes and applicator positions. The number of beamlets used in the treatment planning process was nearly constant for S-RSBT and H-RSBT by using dwell positions separated by 5 and 1.7 mm, respectively, and emission directions separated by 22.5° and 60°, respectively. For all the treatment plans the EQD2 of the HR-CTV was escalated until the EQD{sub 2cc} tolerance of either the bladder, rectum, or sigmoid colon was reached. Results: Treatment times for H-RSBT tended to be shorter than for S-RSBT, with changes of −38.47% to 1.12% with an average of −8.34%. The HR-CTV D{sub 90} changed by −8.81% to 2.08% with an average of −2.46%. Conclusion: H-RSBT is a mechanically feasible technique in the curved applicators needed for cervical cancer brachytherapy. S-RSBT and H-RSBT dose distributions were clinically equivalent for all patients

  10. Applicability of a prototype for determination of absorbed dose using brachytherapy equipment with Ir-192 sources; Aplicabilidade de um prototipo para determinacao da dose absorvida utilizando equipamentos de braquiterapia com fontes de IR-192

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Vivianne Lucia Bormann; Almeida, Mayara Gabriella Oliveira de; Vieira, Rafaela Etelvina de Amorim; Silva, Waldecy Ananias da; Nascimento, Rizia Keila, E-mail: vlsouza@cnen.gov.br, E-mail: mayaradqf@hotmail.com, E-mail: rodriguesss@hootmail.com, E-mail: waldecy@cnen.gov.br, E-mail: riziakeila@hotmail.com [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2014-07-01

    This work aims at the development and improvement of a device to perform the absolute dosimetry sources of Ir-192 using the Fricke solution contained in a flask. The Fricke solution used was prepared using amounts of ferrous ammonium sulfate, sodium chloride and sulfuric acid, diluted with water tri distilled pre-established in the literature. The spectrophotometer used was a UV-VIS spectrophotometer (Beckman DU-640 Counter) for measuring the optical density at wavelength 304 nm. The calculation for determining the radial dose takes into account the radial distance and the angle formed with the transverse axis of the source. As the results obtained can be seen that the states of Pernambuco, Ceara, Paraiba e Piaui are in accordance with the recommendations of international standards of the International Atomic Energy Agency (IAEA), which considers not acceptable a difference greater than 5% of prescribed dose and measured dose.

  11. Brachytherapy of stage II mobile tongue carcinoma. Prediction of local control and QOL

    Directory of Open Access Journals (Sweden)

    Watanabe Hiroshi

    2006-07-01

    Full Text Available Abstract Background There is no consensus as to the prognostic model for brachytherapy of tongue carcinoma. This study was designed to evaluate the prognostic factors for local control based on a large population under a unified treatment policy. Results Between 1970 and 1998, 433 patients with stage II tongue squamous cell carcinoma were treated by low-dose-rate brachytherapy. This series included 277 patients treated with a linear source with a minimum follow-up of 3 years. A spacer was introduced in 1987. The primary local control rates were 85.6%. Conclusion In the multivariate analysis, an invasive growth pattern was a significant factor for local recurrence. The disease-related survival was influenced by old age and an invasive growth pattern. A spacer lowered mandibular bone complications. The growth pattern was the most important factor for recurrence. Brachytherapy was associated with a high cure rate and the use of spacers brought about good quality of life (QOL.

  12. Inquiry and recommendations on the optimization methods in pulsed rate gynecology brachytherapy

    International Nuclear Information System (INIS)

    Metayer, Y.M.; Peiffer, D.P.; Malet, C.; Meyer, P.; Bellec, J.; Chemin, A.

    2006-01-01

    In the frame of the S.T.I.C. ( program of helper to expensive innovative techniques) called 'Use of the gynecology pulsed brachytherapy with optimization of the dose distribution and three dimensional dosimetry' an inquiry has been realised near 20 centers participating to the program. It bears on the practices, the modalities of imaging, the optimization methods and the quality control that is associated. The S.T.I.C. allows to the teams to concentrate their efforts on a modality in brachytherapy. The experience sharing between the centers allows to accelerate the passage to a three dimensional brachytherapy with optimization. The superiority of MRI for the volume description lead the teams to generalize its access, the difficulty of sources locating stays a brake to its generalisation, a synthesis on the methods used are ongoing. It is to notice the absence of use of dosimetry index and common rules of quality control for the dose distribution. The use of Kerma of the application should be generalised. (N.C.)

  13. Variability of Marker-Based Rectal Dose Evaluation in HDR Cervical Brachytherapy

    International Nuclear Information System (INIS)

    Wang Zhou; Jaggernauth, Wainwright; Malhotra, Harish K.; Podgorsak, Matthew B.

    2010-01-01

    In film-based intracavitary brachytherapy for cervical cancer, position of the rectal markers may not accurately represent the anterior rectal wall. This study was aimed at analyzing the variability of rectal dose estimation as a result of interfractional variation of marker placement. A cohort of five patients treated with multiple-fraction tandem and ovoid high-dose-rate (HDR) brachytherapy was studied. The cervical os point and the orientation of the applicators were matched among all fractional plans for each patient. Rectal points obtained from all fractions were then input into each clinical treated plan. New fractional rectal doses were obtained and a new cumulative rectal dose for each patient was calculated. The maximum interfractional variation of distances between rectal dose points and the closest source positions was 1.1 cm. The corresponding maximum variability of fractional rectal dose was 65.5%. The percentage difference in cumulative rectal dose estimation for each patient was 5.4%, 19.6%, 34.6%, 23.4%, and 13.9%, respectively. In conclusion, care should be taken when using rectal markers as reference points for estimating rectal dose in HDR cervical brachytherapy. The best estimate of true rectal dose for each fraction should be determined by the most anterior point among all fractions.

  14. Quality control of the breast cancer treatments on Hdr brachytherapy with TLD-100

    International Nuclear Information System (INIS)

    Torres H, F.; De la Espriella V, N.; Sanchez C, A.

    2014-01-01

    An anthropomorphic Phantom, a female trunk, was built with a natural bone structure and experimental material coated, glycerin and water-based material called JJT to build soft tissue equivalent to the muscle of human tissue, and a polymer (styrofoam) to build the lung as critical organ to simulate the treatment of breast cancer, with high dose rate brachytherapy (Hdr) and sources of Ir-192. The treatments were planned and calculated for the critical organ: Lung, and injury of 2 cm in diameter in breast with Micro Selectron Hdr system and the software Plato Brachytherapy V 14.1 of the Nucletron (Netherlands) which uses the standard protocol of radiotherapy for brachytherapy treatments. The dose experimentally measured with dosimeters TLD-100 LiF: Mg; Ti, which were previously calibrated, were placed in the same positions and bodies mentioned above, with less than 5% uncertainty. The reading dosimeters was carried out in a Harshaw TLD 4500. The results obtained for calculated treatments, using the standard simulator, and the experimental with TLD-100, show a high concordance, as they are on average a ± 1.1% making process becomes in a quality control of this type of treatments. (Author)

  15. Quality control of the breast cancer treatments on Hdr brachytherapy with TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Torres H, F. [Universidad de Cordoba, Materials and Applied Physics Group, 230002 Monteria, Cordoba (Colombia); De la Espriella V, N. [Universidad de Cordoba, Grupo Avanzado de Materiales y Sistemas Complejos, 230002 Monteria, Cordoba (Colombia); Sanchez C, A., E-mail: franciscotorreshoyos@yahoo.com [Universidad de Cordoba, Departamento de Enfermeria, 230002 Monteria, Cordoba (Colombia)

    2014-07-01

    An anthropomorphic Phantom, a female trunk, was built with a natural bone structure and experimental material coated, glycerin and water-based material called JJT to build soft tissue equivalent to the muscle of human tissue, and a polymer (styrofoam) to build the lung as critical organ to simulate the treatment of breast cancer, with high dose rate brachytherapy (Hdr) and sources of Ir-192. The treatments were planned and calculated for the critical organ: Lung, and injury of 2 cm in diameter in breast with Micro Selectron Hdr system and the software Plato Brachytherapy V 14.1 of the Nucletron (Netherlands) which uses the standard protocol of radiotherapy for brachytherapy treatments. The dose experimentally measured with dosimeters TLD-100 LiF: Mg; Ti, which were previously calibrated, were placed in the same positions and bodies mentioned above, with less than 5% uncertainty. The reading dosimeters was carried out in a Harshaw TLD 4500. The results obtained for calculated treatments, using the standard simulator, and the experimental with TLD-100, show a high concordance, as they are on average a ± 1.1% making process becomes in a quality control of this type of treatments. (Author)

  16. Radiation exposure to operating room staff during prostate brachytherapy using iodine-125 seeds

    International Nuclear Information System (INIS)

    Gagna, G.; Amabile, J.C.; Laroche, P.; Gauron, C.

    2011-01-01

    The French defense radiation protection service (SPRA) and the French national institute for research and safety (INRS) conducted a joint study to assess the radiation exposure to operating room staff during prostate brachytherapy using iodine-125 seeds at the Val-de-Grace military hospital. The purpose of the study was the assessment of the effective doses, the equivalent doses to the extremities and lens received by a novice team, the different ambient dose equivalent rates measurements and the delineation of areas. After six brachy-therapies, all the recorded doses with whole-body InLight R OSL and nanoDot R dosimeters remained below the detection limit for the whole staff. The dose rate measured at the end of implantation by an AT1123 R survey meter is about 170 μSv/h at the perineum of the patient. The controlled area limit is estimated to be about 20 cm from the patient perineum. From these results, the authors propose recommendations for the categorization of workers, the delineation of areas and the dose monitoring procedures. This study demonstrates that real-time ultrasound-guided trans-perineal prostate brachytherapy delivers low dose to the operators because of the radioactive source characteristics and the instrumentation providing an effective radiation protection for the surgical team. (authors)

  17. High dose rate brachytherapy using molds after chemoradiotherapy for oral cavity cancer

    International Nuclear Information System (INIS)

    Chatani, Masashi; Tsuboi, Kazuki; Yagi, Masayuki; Fujiwara, Kanta; Tachimoto, Rika; Yoshioka, Hideo

    2012-01-01

    The aim of this study was to investigate the role of the combined use of customized molds and a high dose rate (HDR) remote afterloading brachytherapy apparatus with a 192 Ir microsource in the treatment of superficial oral carcinomas after chemoradiotherapy. Nine patients with oral squamous cell carcinoma who were treated using this combined technique were analyzed retrospectively. The primary sites of the tumors were the mouth floor, gingiva, and soft palate. For each patient, a customized mold was fabricated in which 2-3 afterloading catheters were placed for the 192 Ir source. Three to eight fractions of 3 Gy, 5 mm below the mold surface, were given following external radiotherapy of 24-50 Gy/2 Gy combined with chemotherapy (peplomycin or taxotere). The total dose of HDR brachytherapy ranged from 9 to 24 Gy. The 2-year local control probability was 100% and the 2-year cause-specific survival rate was 100%. No serious complications (id est (i.e.), ulcer or bone exposure) have been observed thus far during the follow-up period of 29-120 months. HDR brachytherapy using the mold technique after chemoradiotherapy is a safe and excellent method for selected early and superficial oral cavity cancers. (author)

  18. American Society for Therapeutic Radiology and Oncology (ASTRO) Emerging Technology Committee report on electronic brachytherapy.

    Science.gov (United States)

    Park, Catherine C; Yom, Sue S; Podgorsak, Matthew B; Harris, Eleanor; Price, Robert A; Bevan, Alison; Pouliot, Jean; Konski, Andre A; Wallner, Paul E

    2010-03-15

    The development of novel technologies for the safe and effective delivery of radiation is critical to advancing the field of radiation oncology. The Emerging Technology Committee of the American Society for Therapeutic Radiology and Oncology appointed a Task Group within its Evaluation Subcommittee to evaluate new electronic brachytherapy methods that are being developed for, or are already in, clinical use. The Task Group evaluated two devices, the Axxent Electronic Brachytherapy System by Xoft, Inc. (Fremont, CA), and the Intrabeam Photon Radiosurgery Device by Carl Zeiss Surgical (Oberkochen, Germany). These devices are designed to deliver electronically generated radiation, and because of their relatively low energy output, they do not fall under existing regulatory scrutiny of radioactive sources that are used for conventional radioisotope brachytherapy. This report provides a descriptive overview of the technologies, current and future projected applications, comparison of competing technologies, potential impact, and potential safety issues. The full Emerging Technology Committee report is available on the American Society for Therapeutic Radiology and Oncology Web site. Copyright 2010. Published by Elsevier Inc.

  19. Dosimetric and clinical comparison between MammoSite and interstitial HDR brachytherapy in treatment of early stage breast cancer after conserving surgery

    International Nuclear Information System (INIS)

    Xiu Xia; Lin, R.; Chu, C.; Issa, C.; Tripuraneni, P.

    2007-01-01

    Objective: To comparatively study dosimetric evaluation, side effects in early and late stage, and cosmetic outcome between MammoSite and interstitial using high-dose-rate (HDR) brachytherapy accelerated partial breast irradiation (APBI) in early stage breast cancer patient after conserving surgery. Methods: From January 2004 to December 2004, 10 breast cancer cases were treated with HDR 192 Ir APBI after Lumpectomy surgery, 6 cases with interstitial brachytherapy, 4 cases with MammoSite. Sources were placed during the operation in all patients, distance from cavity to skin > 5-7 mm in interstitial brachytherapy group, one case is 6.5 mm, 3 cases > 10 mm in MammoSite group. Treatment Target area is 20 mm away from cavity in interstitial brachytherapy group with DHI 0.77, 10 mm away from Balloon margin in MammoSite with DHI 0.73. Results: Follow up 12-24 months while median follow-up was 18 months for the whole group (100%). During the treatment, grade III acute reactions were not seen in both group, grade I or II were seen including: erythema, edema, tenderness and infection. More late toxicity reaction including skin fibrosis, breast tenderness and fat necrosis were observed in interstitial brachytherapy group than that of MammoSite group. Cosmetic outcome evaluation were excellent in 12 months 100% (patient) and 83% (doctor) in interstitial brachytherapy, 100% in MammoSite group, respectively, none recurrence. Conclusions: Interstitial brachytherapy shows more uniformity in dose distribution as well as larger treatment volume, while MammoSite tends to be stable in repeatability and easy in use. Both groups show excellent cosmetic results, with same acute and late reactions. (authors)

  20. In vitro experiments on PDR brachytherapy; In-Vitro-Untersuchungen zur PDR-Brachytherapie

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, P.; Frank, C. [Klinik fuer Radioonkologie, St. Marien-Krankenhaus, Siegen (Germany); Weber, K.J. [Abt. fuer Strahlentherapie, Radiologische Klinik, Heidelberg Univ. (Germany)

    1998-07-01

    Simulating the clinical situation in PDR brachytherapy, fractionation experiments were carried out in the dose rate gradient of afterloading sources. Different dose levels were produced with the same number of fractions in the same overall incubation time. The fractionation schedules which were to be compared with a CLDR reference curve were: 40x0.47 Gy, 20x0.94 Gy, 10x1.88 Gy, 5x3.76 Gy, 2x9.4 Gy given in a period of 20 h and 1x18.8 Gy as a `single dose` exposition. As measured by flow cytometry, the influence of the dose rate in the pulse on cell survival and on cell cycle distribution under superfractionation was examined on V79 cells. V79 spheroids as a model for a slowly growing tumor, reacted according to the radiobiological calculations, as a CLDR equivalancy was achieved with increasing fractionation. Rapidly growing V79 monolayer cells showed an inverse fractionation effect. A superfractionated irradiation with pulses of 0.94 Gy/h respectively 0.47 Gy/0.5 h was significantly more effective than the CLDR irradiation. This inverse fractionation effect in log-phase V79 cells could be attributed to the accumulation of cycling cells in the radiosensitive G2/M phase (G2 block) during protected exposure which was drastically more pronounced for the pulsed scheme. HeLa cells were rather insensitive to changes of fractionation. Superfractionation as well as hypofractionation yielded CLDR equivalent survival curves. (orig./MG) [Deutsch] In Anlehnung an die klinischen Verhaeltnisse der PDR-Brachytherapie wurden Fraktionierungsexperimente im Dosis-Leistungs-Gradienten von Afterloading-Quellen durchgefuehrt. Unterschiedliche Strahlendosen wurden mit der jeweils gleichen Anzahl von Fraktionen und in der jeweils gleichen `Gesamtinkubationszeit` erzeugt. Folgende Fraktionierungen wurden mit einer CLDR-Referenzkurve verglichen: 40x0,47 Gy, 20x0,94 Gy, 10x1,88 Gy, 5x3,76 Gy, 2x9,4 Gy in jeweils 20 Stunden und einmal 18,8 Gy als `Single-dose-`Exposition. Zusaetzlich wurden

  1. MRI dosimetry using an echo-quotient technique for high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Ansbacher, W.

    1996-01-01

    MRI gel dosimetry is a relatively new technique that has many advantages over conventional methods, and is particularly suited to High Dose Rate (HDR) Brachytherapy. The dosimeter has high spatial resolution and a water-equivalent response over a wide range of photon energies. Because it is an integrating dosimeter, it allows for efficient mapping of the dynamically-produced distributions from an HDR source. As an example of this technique, the dose response, which is calibrated in terms of the change in spin-spin relaxation time, has been used to investigate the anisotropy of an HDR source. (author). 1 fig

  2. Does the entire uterus need to be treated in cancer of the cervix? Role of adaptive brachytherapy.

    Science.gov (United States)

    Anker, Christopher J; Cachoeira, Charles V; Boucher, Kenneth M; Rankin, Jim; Gaffney, David K

    2010-03-01

    To evaluate local control and toxicity by use of a method of adaptive cervical brachytherapy (ACB). From 1998 to 2008, we identified 65 cervical cancer patients with FIGO (International Federation of Gynecology and Obstetrics) Stage IB1-IVA disease who received definitive external beam radiation therapy and high-dose rate brachytherapy with tandem and ovoid applicators. As tumors regressed, 45 of 65 patients had the tandem source retracted from the uterine fundus at successive brachytherapy insertions, thus decreasing the number of (192)Ir dwell positions. Tests of trend and Fisher's exact test were used to identify the effect of ACB on disease control and toxicity. Kaplan-Meier analyses were performed to evaluate disease control and late complications. The median follow-up was 24.5 months. Of the patients, 92% received chemotherapy. The 3-year overall survival, 3-year disease-free survival, 3-year distant metastasis-free survival, and local control rates were 67%, 76%, 79%, and 97%, respectively. There was only 1 isolated local failure, and there were no local failures beyond 1 year. Distant failure was involved in 93% of recurrences. No significant trend was identified regarding the extent of retraction of the tandem source start position with either failure or toxicity. Acute and actuarial 3-year late Grade 3 toxicity or greater occurred in 24.6% and 17% of patients, respectively. ACB determined by clinical response yielded excellent local control rates. These data indicate that ACB may be useful in decreasing late toxicities from high-dose rate brachytherapy. With the advent of three-dimensional image-guided brachytherapy, additional methods to adapt treatment technique to changes in tumor volume warrant investigation. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  3. Accurate model-based segmentation of gynecologic brachytherapy catheter collections in MRI-images.

    Science.gov (United States)

    Mastmeyer, Andre; Pernelle, Guillaume; Ma, Ruibin; Barber, Lauren; Kapur, Tina

    2017-12-01

    The gynecological cancer mortality rate, including cervical, ovarian, vaginal and vulvar cancers, is more than 20,000 annually in the US alone. In many countries, including the US, external-beam radiotherapy followed by high dose rate brachytherapy is the standard-of-care. The superior ability of MR to visualize soft tissue has led to an increase in its usage in planning and delivering brachytherapy treatment. A technical challenge associated with the use of MRI imaging for brachytherapy, in contrast to that of CT imaging, is the visualization of catheters that are used to place radiation sources into cancerous tissue. We describe here a precise, accurate method for achieving catheter segmentation and visualization. The algorithm, with the assistance of manually provided tip locations, performs segmentation using image-features, and is guided by a catheter-specific, estimated mechanical model. A final quality control step removes outliers or conflicting catheter trajectories. The mean Hausdorff error on a 54 patient, 760 catheter reference database was 1.49  mm; 51 of the outliers deviated more than two catheter widths (3.4  mm) from the gold standard, corresponding to catheter identification accuracy of 93% in a Syed-Neblett template. In a multi-user simulation experiment for evaluating RMS precision by simulating varying manually-provided superior tip positions, 3σ maximum errors were 2.44  mm. The average segmentation time for a single catheter was 3 s on a standard PC. The segmentation time, accuracy and precision, are promising indicators of the value of this method for clinical translation of MR-guidance in gynecologic brachytherapy and other catheter-based interventional procedures. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Brachytherapy using holmium-166 liquid balloon system for in-stent restenosis: 6 months clinical and angiographic follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M. H.; Kim, S. K.; Cha, K. S.; Kim, Y. D.; Lee, H. S.; Kang, D. Y. [Donga University College of Medicine, Busan (Korea, Republic of)

    2002-07-01

    In western country, 3 systems of brachytherapy using commercial radioactive source has been established. However, brachytherapy using holmium-166 liquid balloon system (HLBS) for the patient with stent restenosis has not been studied enough. 30 patients (male 23, mean age 58.9 7.7) were enrolled. Target dose was 15 Gy at 1 mm distance from the intimal surface. Clinical diagnoses of the study patients included stable angina 10 and unstable angina 20 patients. Target lesion included LAD 19, LCx 5 and RCA 6 arteries. Pre-brachytherapy treatment included cutting balloon angioplasty in 25, rotational atherectomy in 5 patients. Fractionation and stepping was done in 6 patients each. Follow-up angiography was done in 19 patients. Of them, 4 cases developed angiographic restenosis (21%) including 3 cases of total occlusion. 6 month MACE (major adverse cardiac event) occurred in 5 patients including one sudden cardiac death in a patient with 80 year-old, triple-vessel diseased patient. Vascular brachytherapy using HLBS is a safe and effective treatment modality for in-stent restenosis showing acceptable angiographic and clinical result.

  5. Nanoparticles for intravascular applications: physicochemical characterization and cytotoxicity testing.

    Science.gov (United States)

    Matuszak, Jasmin; Baumgartner, Jens; Zaloga, Jan; Juenet, Maya; da Silva, Acarília Eduardo; Franke, Danielle; Almer, Gunter; Texier, Isabelle; Faivre, Damien; Metselaar, Josbert M; Navarro, Fabrice P; Chauvierre, Cédric; Prassl, Ruth; Dézsi, László; Urbanics, Rudolf; Alexiou, Christoph; Mangge, Harald; Szebeni, János; Letourneur, Didier; Cicha, Iwona

    2016-03-01

    We report the physicochemical analysis of nanosystems intended for cardiovascular applications and their toxicological characterization in static and dynamic cell culture conditions. Size, polydispersity and ζ-potential were determined in 10 nanoparticle systems including liposomes, lipid nanoparticles, polymeric and iron oxide nanoparticles. Nanoparticle effects on primary human endothelial cell viability were monitored using real-time cell analysis and live-cell microscopy in static conditions, and in a flow model of arterial bifurcations. The majority of tested nanosystems were well tolerated by endothelial cells up to the concentration of 100 μg/ml in static, and up to 400 μg/ml in dynamic conditions. Pilot experiments in a pig model showed that intravenous administration of liposomal nanoparticles did not evoke the hypersensitivity reaction. These findings are of importance for future clinical use of nanosystems intended for intravascular applications.

  6. Intravascular Myopericytoma in the Heel: Case Report and Literature Review

    Science.gov (United States)

    Valero, José; Salcini, José L.; Gordillo, Luis; Gallart, José; González, David; Deus, Javier; Lahoz, Manuel

    2015-01-01

    Abstract Intravascular myopericytoma (IVMP), regarded as a variant of myopericytoma, is a rare tumor. Very few cases have been described, none in the foot. The first case of IVMP located in the heel of the foot is described in this article. A literature review is reported of all cases of IVMP published in the English literature. A 48-year-old man possessed an IVMP on the heel of the right foot. The physical examination and histopathological and ultrasound studies are described. The literature review yielded 5 cases of IVMP, 2 of which were in the thigh and 1 each in the oral mucosa, the periorbital region, and the leg. The possibility that these lesions may be malignant suggests that the histopathological study of vascular tumors should include immunohistochemical tests. PMID:25789958

  7. Theoretical model of intravascular paramagnetic tracers effect on tissue relaxation

    DEFF Research Database (Denmark)

    Kjølby, Birgitte Fuglsang; Østergaard, Leif; Kiselev, Valerij G

    2006-01-01

    The concentration of MRI tracers cannot be measured directly by MRI and is commonly evaluated indirectly using their relaxation effect. This study develops a comprehensive theoretical model to describe the transverse relaxation in perfused tissue caused by intravascular tracers. The model takes...... into account a number of individual compartments. The signal dephasing is simulated in a semianalytical way by embedding Monte Carlo simulations in the framework of analytical theory. This approach yields a tool for fast, realistic simulation of the change in the transverse relaxation. The results indicate...... with bulk blood. The enhancement of relaxation in tissue is due to the contrast in magnetic susceptibility between blood vessels and parenchyma induced by the presence of paramagnetic tracer. Beyond the perfusion measurements, the results can be applied to quantitation of functional MRI and to vessel size...

  8. Evaluation of Disseminated Intravascular Coagulation in the Craniocerebral Traumas

    Directory of Open Access Journals (Sweden)

    Faruk Altinel

    2014-06-01

    Full Text Available Traumatic injury is one of the most important cause of disseminated intravascular coagulation (DIC. It occurs because of blood loss and hemodilution due to fluid resuscitation. The incidence of trauma associated DIC is mainly higher in the craniocerebral traumas. Even though craniocerebral trauma related DIC is well defined, the pathophysiology has been poorly characterized in the literature. Due to the fact that brain tissue is highly significant for procoagulant molecules, craniocerebral traumas are closely related to DIC. In the current study, 30 patients admitted to emergency room have been considered on the first and fifth day of admission to the hospital for the coagulation tests to evaluate DIC in both two groups. [Cukurova Med J 2014; 39(3.000: 488-495

  9. Scary gas: intravascular, intracranial, and intraspinal ectopic gas (part III).

    Science.gov (United States)

    Sandstrom, Claire K; Osman, Sherif F; Linnau, Ken F

    2017-08-01

    While ectopic gas can be a sign of dangerous disease requiring immediate medical or surgical intervention, it can also be an incidental and benign finding. Intravenous gas and spinal vacuum gas are common and almost always benign. Intravascular gas is most often related to instrumentation and, if intraarticular, can cause end-organ ischemia; however, treatment is usually supportive. Pneumocephalus arises from a communication with paranasal sinuses or mastoids more often than from meningeal infection and can usually be managed nonoperatively. In part 3 of this series, the different causes of ectopic gas in the vessels, skull, and spine are reviewed, as are the imaging features that can help to narrow the differential diagnosis.

  10. Mathematical Modeling of Intravascular Blood Coagulation under Wall Shear Stress

    Science.gov (United States)

    Rukhlenko, Oleksii S.; Dudchenko, Olga A.; Zlobina, Ksenia E.; Guria, Georgy Th.

    2015-01-01

    Increased shear stress such as observed at local stenosis may cause drastic changes in the permeability of the vessel wall to procoagulants and thus initiate intravascular blood coagulation. In this paper we suggest a mathematical model to investigate how shear stress-induced permeability influences the thrombogenic potential of atherosclerotic plaques. Numerical analysis of the model reveals the existence of two hydrodynamic thresholds for activation of blood coagulation in the system and unveils typical scenarios of thrombus formation. The dependence of blood coagulation development on the intensity of blood flow, as well as on geometrical parameters of atherosclerotic plaque is described. Relevant parametric diagrams are drawn. The results suggest a previously unrecognized role of relatively small plaques (resulting in less than 50% of the lumen area reduction) in atherothrombosis and have important implications for the existing stenting guidelines. PMID:26222505

  11. Robust intravascular optical coherence elastography by line correlations

    International Nuclear Information System (INIS)

    Soest, Gijs van; Mastik, Frits; Jong, Nico de; Steen, Anton F W van der

    2007-01-01

    We present a new method for intravascular optical coherence elastography, which is robust against motion artefacts. It employs the correlation between adjacent lines, instead of subsequent frames. Pressure to deform the tissue is applied synchronously with the line scan rate of the optical coherence tomography (OCT) instrument. The viability of the method is demonstrated with a simulation study. We find that the root mean square (rms) error of the displacement estimate is 0.55 μm, and the rms error of the strain is 0.6%. It is shown that high-strain spots in the vessel wall, such as observed at the sites of vulnerable atherosclerotic lesions, can be detected with the technique

  12. Sources

    International Nuclear Information System (INIS)

    Duffy, L.P.

    1991-01-01

    This paper discusses the sources of radiation in the narrow perspective of radioactivity and the even narrow perspective of those sources that concern environmental management and restoration activities at DOE facilities, as well as a few related sources. Sources of irritation, Sources of inflammatory jingoism, and Sources of information. First, the sources of irritation fall into three categories: No reliable scientific ombudsman to speak without bias and prejudice for the public good, Technical jargon with unclear definitions exists within the radioactive nomenclature, and Scientific community keeps a low-profile with regard to public information. The next area of personal concern are the sources of inflammation. This include such things as: Plutonium being described as the most dangerous substance known to man, The amount of plutonium required to make a bomb, Talk of transuranic waste containing plutonium and its health affects, TMI-2 and Chernobyl being described as Siamese twins, Inadequate information on low-level disposal sites and current regulatory requirements under 10 CFR 61, Enhanced engineered waste disposal not being presented to the public accurately. Numerous sources of disinformation regarding low level radiation high-level radiation, Elusive nature of the scientific community, The Federal and State Health Agencies resources to address comparative risk, and Regulatory agencies speaking out without the support of the scientific community

  13. The american brachytherapy society recommendations for permanent prostate brachytherapy postimplant dosimetric analysis

    International Nuclear Information System (INIS)

    Nag, Subir; Bice, William; Wyngaert, Keith de; Prestidge, Bradley; Stock, Richard; Yu Yan

    2000-01-01

    Purpose: The purpose of this report is to establish guidelines for postimplant dosimetric analysis of permanent prostate brachytherapy. Methods: Members of the American Brachytherapy Society (ABS) with expertise in prostate dosimetry evaluation performed a literature review and supplemented with their clinical experience formulated guidelines for performing and analyzing postimplant dosimetry of permanent prostate brachytherapy. Results: The ABS recommends that postimplant dosimetry should be performed on all patients undergoing permanent prostate brachytherapy for optimal patient care. At present, computed tomography (CT)-based dosimetry is recommended, based on availability cost and the ability to image the prostate as well as the seeds. Additional plane radiographs should be obtained to verify the seed count. Until the ideal postoperative interval for CT scanning has been determined, each center should perform dosimetric evaluation of prostate implants at a consistent postoperative interval. This interval should be reported. Isodose displays should be obtained at 50%, 80%, 90%, 100%, 150%, and 200% of the prescription dose and displayed on multiple cross-sectional images of the prostate. A dose-volume histogram (DVH) of the prostate should be performed and the D 90 (dose to 90% of the prostate gland) reported by all centers. Additionally, the D 80, D 100, the fractional V 80, V 90, V 100, V 150, and V 200, (i.e., the percentage of prostate volume receiving 80%, 90%, 100%, 150%, and 200% of the prescribed dose, respectively), the rectal, and urethral doses should be reported and ultimately correlated with clinical outcome in the research environment. On-line real-time dosimetry, the effects of dose heterogeneity, and the effects of tissue heterogeneity need further investigation. Conclusion: It is essential that postimplant dosimetry should be performed on all patients undergoing permanent prostate brachytherapy. Guidelines were established for the performance

  14. A survey of quality control practices for high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy in the United Kingdom

    Science.gov (United States)

    Bidmead, Margaret; Nisbet, Andrew

    2012-01-01

    Purpose A survey of quality control (QC) currently undertaken in UK radiotherapy centres for high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy has been conducted. The purpose was to benchmark current accepted practice of tests, frequencies and tolerances to assure acceptable HDR/PDR equipment performance. It is 20 years since a similar survey was conducted in the UK and the current review is timed to coincide with a revision of the IPEM Report 81 guidelines for quality control in radiotherapy. Material and methods All radiotherapy centres in the UK were invited by email to complete a comprehensive questionnaire on their current brachytherapy QC practice, including: equipment type, patient workload, source calibration method, level of image guidance for planning, prescribing practices, QC tests, method used, staff involved, test frequencies, and acceptable tolerance limits. Results Survey data was acquired between June and August 2012. Of the 64 centres invited, 47 (73%) responded, with 31 centres having brachytherapy equipment (3 PDR) and fully completing the survey, 13 reporting no HDR/PDR brachytherapy, and 3 intending to commence HDR brachytherapy in the near future. All centres had comprehensive QC schedules in place and there was general agreement on key test frequencies and tolerances. Greatest discord was whether source strength for treatment planning should be derived from measurement, as at 58% of centres, or from the certified value, at 42%. IPEM Report 81 continues to be the most frequently cited source of QC guidance, followed by ESTRO Booklet No. 8. Conclusions A comprehensive survey of QC practices for HDR/PDR brachytherapy in UK has been conducted. This is a useful reference to which centres may benchmark their own practice. However, individuals should take a risk-assessment based approach, employing full knowledge of local equipment, clinical procedures and available test equipment in order to determine individual QC needs. PMID:23378853

  15. Suitability of point kernel dose calculation techniques in brachytherapy treatment planning

    Directory of Open Access Journals (Sweden)

    Lakshminarayanan Thilagam

    2010-01-01

    Full Text Available Brachytherapy treatment planning system (TPS is necessary to estimate the dose to target volume and organ at risk (OAR. TPS is always recommended to account for the effect of tissue, applicator and shielding material heterogeneities exist in applicators. However, most brachytherapy TPS software packages estimate the absorbed dose at a point, taking care of only the contributions of individual sources and the source distribution, neglecting the dose perturbations arising from the applicator design and construction. There are some degrees of uncertainties in dose rate estimations under realistic clinical conditions. In this regard, an attempt is made to explore the suitability of point kernels for brachytherapy dose rate calculations and develop new interactive brachytherapy package, named as BrachyTPS, to suit the clinical conditions. BrachyTPS is an interactive point kernel code package developed to perform independent dose rate calculations by taking into account the effect of these heterogeneities, using two regions build up factors, proposed by Kalos. The primary aim of this study is to validate the developed point kernel code package integrated with treatment planning computational systems against the Monte Carlo (MC results. In the present work, three brachytherapy applicators commonly used in the treatment of uterine cervical carcinoma, namely (i Board of Radiation Isotope and Technology (BRIT low dose rate (LDR applicator and (ii Fletcher Green type LDR applicator (iii Fletcher Williamson high dose rate (HDR applicator, are studied to test the accuracy of the software. Dose rates computed using the developed code are compared with the relevant results of the MC simulations. Further, attempts are also made to study the dose rate distribution around the commercially available shielded vaginal applicator set (Nucletron. The percentage deviations of BrachyTPS computed dose rate values from the MC results are observed to be within plus/minus 5

  16. Caudal epidural anesthesia during intracavitary brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Isoyama-Shirakawa, Yuko; Abe, Madoka; Nakamura, Katsumasa

    2015-01-01

    It has been suggested that pain control during intracavitary brachytherapy for cervical cancer is insufficient in most hospitals in Japan. Our hospital began using caudal epidural anesthesia during high-dose-rate (HDR) intracavitary brachytherapy in 2011. The purpose of the present study was to retrospectively investigate the effects of caudal epidural anesthesia during HDR intracavitary brachytherapy for cervical cancer patients. Caudal epidural anesthesia for 34 cervical cancer patients was performed during HDR intracavitary brachytherapy between October 2011 and August 2013. We used the patients' self-reported Numeric Rating Scale (NRS) score at the first session of HDR intracavitary brachytherapy as a subjective evaluation of pain. We compared NRS scores of the patients with anesthesia with those of 30 patients who underwent HDR intracavitary brachytherapy without sacral epidural anesthesia at our hospital between May 2010 and August 2011. Caudal epidural anesthesia succeeded in 33 patients (97%), and the NRS score was recorded in 30 patients. The mean NRS score of the anesthesia group was 5.17 ± 2.97, significantly lower than that of the control group's 6.80 ± 2.59 (P = 0.035). The caudal epidural block resulted in no side-effects. Caudal epidural anesthesia is an effective and safe anesthesia option during HDR intracavitary brachytherapy for cervical cancer. (author)

  17. Disseminated intravascular coagulation or acute coagulopathy of trauma shock early after trauma? A prospective observational study

    DEFF Research Database (Denmark)

    Johansson, Per Ingemar; Sorensen, Anne Marie; Perner, Anders

    2011-01-01

    ABSTRACT: INTRODUCTION: It is debated whether the early trauma induced coagulopathy (TIC) in severely injured patients reflects disseminated intravascular coagulation (DIC) with a fibrinolytic phenotype, acute coagulopathy of trauma shock (ACoTS) or yet other entities. This study investigated...

  18. Effect of catecholamines and insulin on plasma volume and intravascular mass of albumin in man

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J; Larsen, S

    1989-01-01

    1. The effect of intravenous catecholamine infusions and of intravenous insulin on plasma volume and intravascular mass of albumin was investigated in healthy males. 2. Physiological doses of adrenaline (0.5 microgram/min and 3 microgram/min) increased peripheral venous packed cell volume....../min, packed cell volume increased, plasma volume decreased and intravascular mass of albumin decreased significantly. During noradrenaline infusion at 6 micrograms/min, packed cell volume increased and plasma volume decreased, but intravascular mass of albumin did not change. 4. Application...... of a hyperinsulinaemic, euglycaemic glucose clamp led to an increase in transcapillary escape rate of albumin and a decrease in intravascular mass of albumin. Packed cell volume remained constant, while plasma volume, measured by radiolabelled albumin, decreased. 5. We conclude that the previously reported changes...

  19. Use of Intravascular Ultrasound Imaging in Percutaneous Coronary Intervention to Treat Left Main Coronary Artery Disease.

    Science.gov (United States)

    De Maria, Giovanni Luigi; Banning, Adrian P

    2017-05-01

    Due to its potential prognostic implications and technical complexity, revascularisation of left main coronary artery (LMCA) disease requires careful consideration. Since publication of the results of the SYNTAX study, and more recently the EXCEL and NOBLE trials, there has been particular interest in percutaneous revascularisation of the LMCA. It is becoming clear that percutaneous revascularisation of LMCA disease requires appropriate lesion preparation and carefully optimised stenting in order to offer patients a treatment option as effective as coronary artery bypass grafting. For this reason intravascular imaging, and especially intravascular ultrasound, is becoming a key procedural step in LMCA percutaneous coronary intervention. In the current review paper we analyse the role of intravascular imaging with intravascular ultrasound in LMCA percutaneous coronary intervention, focusing on the main applications in this context from lesion assessment to stent sizing and optimisation.

  20. Accuracy of electrocardiographic-gated versus nongated volumetric intravascular ultrasound measurements of coronary arterial narrowing

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per

    2007-01-01

    Intravascular ultrasound (IVUS) allows precise measurements of plaque plus media (P+M) volume and neointimal hyperplasia after coronary artery stenting. Conventional IVUS volumetric analysis is performed mostly without electrocardiographically gated acquisition, and the IVUS images are selected...

  1. Use of Monte Carlo Methods for determination of isodose curves in brachytherapy

    International Nuclear Information System (INIS)

    Vieira, Jose Wilson

    2001-08-01

    Brachytherapy is a special form of cancer treatment in which the radioactive source is very close to or inside the tumor with the objective of causing the necrosis of the cancerous tissue. The intensity of cell response to the radiation varies according to the tissue type and degree of differentiation. Since the malign cells are less differentiated than the normal ones, they are more sensitive to the radiation. This is the basis for radiotherapy techniques. Institutes that work with the application of high dose rates use sophisticated computer programs to calculate the necessary dose to achieve the necrosis of the tumor and the same time, minimizing the irradiation of tissues and organs of the neighborhood. With knowledge the characteristics of the source and the tumor, it is possible to trace isodose curves with the necessary information for planning the brachytherapy in patients. The objective of this work is, using Monte Carlo techniques, to develop a computer program - the ISODOSE - which allows to determine isodose curves in turn of linear radioactive sources used in brachytherapy. The development of ISODOSE is important because the available commercial programs, in general, are very expensive and practically inaccessible to small clinics. The use of Monte Carlo techniques is viable because they avoid problems inherent to analytic solutions as, for instance , the integration of functions with singularities in its domain. The results of ISODOSE were compared with similar data found in the literature and also with those obtained at the institutes of radiotherapy of the 'Hospital do Cancer do Recife' and of the 'Hospital Portugues do Recife'. ISODOSE presented good performance, mainly, due to the Monte Carlo techniques, that allowed a quite detailed drawing of the isodose curves in turn of linear sources. (author)

  2. Interstitial brachytherapy for orbital soft tissue sarcoma: an innovative technique.

    Science.gov (United States)

    Laskar, Siddhartha; Pilar, Avinash; Khanna, Nehal; Ghadi, Yogesh

    2017-10-01

    To report an innovative technique of interstitial brachytherapy developed for treatment of orbital soft tissue tumors. A 4-month-old child diagnosed with rhabdomyosarcoma of orbit was treated with multiagent chemotherapy (CTh) and brachytherapy. Pre-planning computed tomography (CT) images were obtained and clinical target volume (CTV) was defined using the pre-treatment magnetic resonance imaging (MRI). Brachytherapy plan was generated for deciding optimal catheter placement. With the child under general anesthesia, catheter entry points were extrapolated and marked on the skin as determined from the pre-planning CT scan. Implantation of catheters was performed as per pre-determined catheter position and depths. Brachytherapy plan was generated and evaluated using dose volume histograms (DVH). A comparative external beam radiotherapy (EBRT) plan using RapidArc was also generated for the CTV with a 3 mm margin as the planning target volume (PTV). The mean CTV dose with brachytherapy was 158% compared to 101% with RapidArc. The CTV V 100 was 90% for brachytherapy vs. 95% for RapidArc. The mean dose to Lt Lens were 51% and 60%, respectively for brachytherapy and RapidArc, while the corresponding mean doses to the bony orbit were 39% and 68%, respectively. Follow-up MRI at 3 months showed complete response of the tumor. Interstitial brachytherapy for orbit using this innovative technique is a safe and effective modality of local treatment for appropriately selected orbital soft tissue tumors. Brachytherapy resulted in excellent disease control with significant reduction of dose to surrounding ocular structures compared to EBRT.

  3. sources

    Directory of Open Access Journals (Sweden)

    Shu-Yin Chiang

    2002-01-01

    Full Text Available In this paper, we study the simplified models of the ATM (Asynchronous Transfer Mode multiplexer network with Bernoulli random traffic sources. Based on the model, the performance measures are analyzed by the different output service schemes.

  4. A study of Brachytherapy for Intraocular Tumor

    International Nuclear Information System (INIS)

    Ji, Kwang Soo; Yoo, Dae Hyun; Lee, Sung Goo; Kim, Jae Hu; Ji, Young Hun

    1996-01-01

    The eye enucleation or external-beam radiation therapy that has been commonly used for the treatment of intraocular tumor have demerits of visual loss and in deficiency of effective tumor dose. Recently, brachytherapy using the plaques containing radioisotope-now treatment method that decrease the demerits of the above mentioned treatment methods and increase the treatment effect-is introduced and performed in the countries, Our purpose of this research is to design suitable shape of plaque for the ophthalmic brachytherapy, and to measure absorbed doses of Ir-192 ophthalmic plaque and thereby calculate the exact radiation dose of tumor and it's adjacent normal tissue. In order to brachytherapy for intraocular tumor, 1. to determine the eye model and selected suitable radioisotope 2. to design the suitable shape of plaque 3. to measure transmission factor and dose distribution for custom made plaques 4. to compare with the these data and results of computer dose calculation models. The result were as followed. 1. Eye model was determined as a 25 mm diameter sphere, Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15 mm, 17 mm and 20 mm in diameter, and 1.5 mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5 mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ±10% and distance deviations are within 0.4 mm Maximum error is -11.3% and 0.8 mm, respectively. As a result of it, we can treat the intraocular tumor more effectively by using custom made gold plaque and Ir-192

  5. Characteristics of the radiochromic film Gafchromictm EBT3 model for use in brachytherapy; Caracterizacao do filme radiocromico Gafchromictm modelo EBT3 para uso em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Luvizotto, Jessica

    2015-07-01

    Brachytherapy is a radiotherapy treatment modality using radioactive sealed sources within walking distance of the tumor, reducing the risk of applying an unwanted dose to adjacent healthy tissues. For brachytherapy is reliable, it is necessary to establish a dosimetric practices program aimed at determining the optimal dose of radiation for this radiotherapy practice. This paper presents the application of two methodologies for the dosimetry using radiochromic films. Experimental measurements were performed with EBT3 films in phantoms consisting of homogeneous and heterogeneous material (lung, bone and soft tissue) built especially for dose measurements in brachytherapy. The processing and analysis of the resulting images of the experimental procedure were performed with ImageJ software and MATLAB. The results were evaluated from comparisons dose of experimental measurements and simulations obtained by the Monte Carlo method. (author)

  6. Gallium SPECT detection of neoplastic intravascular obstruction of the superior vena cava

    International Nuclear Information System (INIS)

    Swayne, L.C.; Kaplan, I.L.

    1989-01-01

    A rare case of an intravascular neoplastic obstruction of the superior vena cava is discussed. The lesion was detected with gallium single photon emission computed tomography (SPECT) despite a normal appearance on a concurrent radiographic CT study. A computer-generated composite SPECT-CT image confirmed the intravascular localization of the radioisotope, and a subsequent CT-guided transthoracic needle biopsy revealed a poorly differentiated adenocarcinoma

  7. [Cardiovascular depression and intravascular hemolysis secondary to ethanol injection for arteriovenous malformation].

    Science.gov (United States)

    Cai, Mei-Hua; Su, Li-Xin; Qiu, Lin

    2016-08-01

    Ethanol is the only liquid embolization agent which can cure arteriovenous malformation. Complications of ethanol embolization are not rare including local tissue injury, intravascular hemolysis and cardiovascular depression even collapse, etc. This report presented a case of long time cardiovascular depression and intravascular hemolysis secondary to ethanol embolotherapy of right ear. In order to avoid the fatal complications that are associated with ethanol sclerotherapy, anesthesiologists should consider the use of continuously invasive hemodynamic monitoring while surgeons should carefully choose the dose of ethanol.

  8. A mechanical system design of the iridium-192 isotope wire in cervical cancer brachytherapy with medium dose rate

    International Nuclear Information System (INIS)

    Ari Satmoko; Sanda; Tri Harjanto; Atang Susila

    2010-01-01

    In 2010, brachytherapy engineering development activities have a purpose to establish a detailed design of the cervical cancer brachytherapy with medium dose rate. The brachytherapy will use an Iridium-92 source with the emitting radiation of 5 to 10 Curies. The source is wrapped in SS-316 capsule and carried by a SS-316 wire having diameter of about 1 mm dan length of 1800 mm. As part of this activity, the preliminary design of the mechanical drive systems for the isotope source has been developed. The technical specifications for the main components of the mechanical drive system have been successfully determined. This is started by studying the concept design, performing calculations, determining technical specifications, and finally defining the main components. From the evaluation, some components were decided: a stepper motor PK264A1-SG10, needle bearing NKI-10/20, spiral tube in SS316-1/8'' with 120 mm in diameter, rubber-based belts with a width of 20 mm, and aluminium drum with a diameter of 100 mm. Not all components could be identified in detail, especially for the components that do not exist in the marketplace and have to be created ourself Since the main components have been identified, the detailed design step of the mechanical drive systems for the isotope source can be performed. (author)

  9. The mechanical system design of the iridium-192 isotope wire in cervical cancer brachytherapy with medium dose rate

    International Nuclear Information System (INIS)

    Ari Satmoko; Sanda; Tri Harjanto; Atang Susila

    2010-01-01

    In 2010, brachytherapy engineering activities have a purpose to establish a detailed design of the cervical cancer brachytherapy with medium dose rate. The brachytherapy will use an Iridium-92 source with the emiting radiation of 5 to 10 Curies. The source is wrapped in SS-316 capsule and carried by a SS-316 wire having diameter of about 1 mm dan length of 1800 mm. As part of this activity, the preliminary design of the mechanical drive systems for the isotope source has been developed. The technical specifications for the main components of the mechanical drive system have been successfully determined. This is started by studying the concept design, performing calculations, determining technical specifications, and finally defining the main components. From the evaluation, some components were decided: a stepper motor PK264A1-SG10, needle bearing NKI-10/20, spiral tube in SS316-1/8'' with 120 mm in diameter, rubber-based belts with a width of 20 mm, and aluminium drum with a diameter of 100 mm. Not all components could be identified in detail, especially for the components that do not exist in the market place and have to be created ourself. Since the main components have been identified, the detailed design step of the mechanical drive systems for the isotope source can be performed. (author)

  10. AAPM and GEC-ESTRO guidelines for image-guided robotic brachytherapy: Report of Task Group 192

    Energy Technology Data Exchange (ETDEWEB)

    Podder, Tarun K., E-mail: tarun.podder@uhhospitals.org [Department of Radiation Oncology, University Hospitals, Case Western Reserve University, Cleveland, Ohio 44122 (United States); Beaulieu, Luc [Department of Radiation Oncology, Centre Hospitalier Univ de Quebec, Quebec G1R 2J6 (Canada); Caldwell, Barrett [Schools of Industrial Engineering and Aeronautics and Astronautics, Purdue University, West Lafayette, Indiana 47907 (United States); Cormack, Robert A. [Department of Radiation Oncology, Harvard Medical School, Boston, Massachusetts 02115 (United States); Crass, Jostin B. [Department of Radiation Oncology, Vanderbilt University, Nashville, Tennessee 37232 (United States); Dicker, Adam P.; Yu, Yan [Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania 19107 (United States); Fenster, Aaron [Department of Imaging Research, Robarts Research Institute, London, Ontario N6A 5K8 (Canada); Fichtinger, Gabor [School of Computer Science, Queen’s University, Kingston, Ontario K7L 3N6 (Canada); Meltsner, Michael A. [Philips Radiation Oncology Systems, Fitchburg, Wisconsin 53711 (United States); Moerland, Marinus A. [Department of Radiotherapy, University Medical Center Utrecht, Utrecht, 3508 GA (Netherlands); Nath, Ravinder [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut 06520 (United States); Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Salcudean, Tim [Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia V6T 1Z4 (Canada); Song, Danny Y. [Department of Radiation Oncology, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 (United States); Thomadsen, Bruce R. [Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53705 (United States)

    2014-10-15

    should mimic the real operating procedure as closely as possible. Additional recommendations on robotic brachytherapy systems include display of the operational state; capability of manual override; documented policies for independent check and data verification; intuitive interface displaying the implantation plan and visualization of needle positions and seed locations relative to the target anatomy; needle insertion in a sequential order; robot–clinician and robot–patient interactions robustness, reliability, and safety while delivering the correct dose at the correct site for the correct patient; avoidance of excessive force on radioactive sources; delivery confirmation of the required number or position of seeds; incorporation of a collision avoidance system; system cleaning, decontamination, and sterilization procedures. These recommendations are applicable to end users and manufacturers of robotic brachytherapy systems.

  11. Brachytherapy in the treatment of cervical cancer: a review.

    Science.gov (United States)

    Banerjee, Robyn; Kamrava, Mitchell

    2014-01-01

    Dramatic advances have been made in brachytherapy for cervical cancer. Radiation treatment planning has evolved from two-dimensional to three-dimensional, incorporating magnetic resonance imaging and/or computed tomography into the treatment paradigm. This allows for better delineation and coverage of the tumor, as well as improved avoidance of surrounding organs. Consequently, advanced brachytherapy can achieve very high rates of local control with a reduction in morbidity, compared with historic approaches. This review provides an overview of state-of-the-art gynecologic brachytherapy, with a focus on recent advances and their implications for women with cervical cancer.

  12. High dose rate brachytherapy for superficial cancer of the esophagus

    International Nuclear Information System (INIS)

    Maingon, Philippe; D'Hombres, Anne; Truc, Gilles; Barillot, Isabelle; Michiels, Christophe; Bedenne, Laurent; Horiot, Jean Claude

    2000-01-01

    Purpose: We analyzed our experience with external radiotherapy, combined modality treatment, or HDR brachytherapy alone to limited esophageal cancers. Methods and Materials: From 1991 to 1996, 25 patients with limited superficial esophagus carcinomas were treated by high dose rate brachytherapy. The mean age was 63 years (43-86 years). Five patients showed superficial local recurrence after external radiotherapy. Eleven patients without invasion of the basal membrane were staged as Tis. Fourteen patients with tumors involving the submucosa without spreading to the muscle were staged as T1. Treatment consisted of HDR brachytherapy alone in 13 patients, external radiotherapy and brachytherapy in 8 cases, and concomitant chemo- and radiotherapy in 4 cases. External beam radiation was administered to a total dose of 50 Gy using 2 Gy daily fractions in 5 weeks. In cases of HDR brachytherapy alone (13 patients), 6 applications were performed once a week. Results: The mean follow-up is 31 months (range 24-96 months). Twelve patients received 2 applications and 13 patients received 6 applications. Twelve patients experienced a failure (48%), 11/12 located in the esophagus, all of them in the treated volume. One patient presented an isolated distant metastasis. In the patients treated for superficial recurrence, 4/5 were locally controlled (80%) by brachytherapy alone. After brachytherapy alone, 8/13 patients were controlled (61%). The mean disease-free survival is 14 months (1-36 months). Overall survival is 76% at 1 year, 37% at 2 years, and 14% at 3 years. Overall survival for Tis patients is 24% vs. 20% for T1 (p 0.83). Overall survival for patients treated by HDR brachytherapy alone is 43%. One patient presented with a fistula with local failure after external radiotherapy and brachytherapy. Four stenosis were registered, two were diagnosed on barium swallowing without symptoms, and two required dilatations. Conclusion: High dose rate brachytherapy permits the treating

  13. Construction of a anthropomorphic phantom for dose measurement in hands in brachytherapy procedures; Construccion de un fantoma antropomorfico para mediciones de dosis en manos en procedimientos de braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Papp, Cinthia M., E-mail: cinthia_papp@yahoo.com.ar [Comision Nacional de Energia Atomica (IH/UNCUYO/CNEA), Mendoza (Argentina). Universidad Nacional de Cuyo. Instituto Balseiro; Ortiz, Arnulfo; Alvarez, Guillermo, E-mail: arnot@gmail.com, E-mail: galvarez@fuesmen.edu.ar [Fundacion Escuela de Medicina Nuclear (FUESMEN), Mendoza (Argentina)

    2013-11-01

    The main objective of this work was to show the differences between the dose value measured by dosimeter endpoint and the values measured in different points inside the hand during brachytherapy procedures. For this, the procedures involved in the handling of sources were analyzed and the simulated using an anthropomorphic phantom hand.

  14. Comparison BIPM.RI(I)-K8 of high dose-rate Ir-192 brachytherapy standards for reference air kerma rate of the VSL and the BIPM

    DEFF Research Database (Denmark)

    Alvarez, J.T.; De Pooter, J.A.; Andersen, Claus E.

    2014-01-01

    An indirect comparison of the standards for reference air kerma rate for 192Ir high dose rate brachytherapy sources of the Dutch Metrology Institute (VSL), The Netherlands, and of the Bureau International des Poids et Mesures (BIPM) was carried out at the VSL in November 2009. The comparison resu...

  15. Development of irradiation support devices for production of brachytherapy seeds

    Energy Technology Data Exchange (ETDEWEB)

    Mattos, Fabio R.; Rostelato, Maria Elisa C.M.; Zeituni, Carlos A.; Souza, Carla D.; Moura, Joao A.; Peleias Junior, Fernando S.; Karan Junior, Dib; Feher, Anselmo; Oliveira, Tiago B.; Benega, Marcos A.G., E-mail: tiagooliveira298@gmail.com, E-mail: mattos.fr@gmail.com, E-mail: elisaros@ipen.br, E-mail: czeituni@ipen.br, E-mail: carladdsouza@yahoo.com.br, E-mail: jamoura@ipen.br, E-mail: ernandopeleias@gmail.com, E-mail: s, E-mail: dib.karan@usp.br, E-mail: afeher@ipen.br, E-mail: marcosagbenega@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Ophthalmic tumors treatment with brachytherapy sources has been widely used as a primary or secondary therapy for non-malignant or malignant tumors, for example, choroid melanoma, and retinoblastoma. Ruthenium-106, Iodine-125, Palladium -103, Gold-198 and Iridium-192, are some radionuclides that can be applied for treatment of ocular tumors. These sources are in small sizes (a few millimeters) and different shapes (rods, wires, disks). To ensure high accuracy during treatment, they are positioned in eye applicators, specially designed to fit on the surface of tumor. The Nuclear and Energy Research Institute (IPEN/CNEN) in a partnership with Paulista Medicine School (UNIFESP) created a project that aims to develop a prototype of Iridium-192 seeds for treatment of eye cancer. This seed consists in a core of Ir -Pt alloy (20%-80%) with a length of 3 mm, to be activated in IPEN's IEA-R1 Reactor, and a titanium capsule sealing the core. It was imperative to develop a sustainer device for irradiation. This piece is used to avoid overlapping of one cores and, therefore, avoiding the 'shadow effect' that does not allow full activation of each core due to the high density. (author)

  16. Development of irradiation support devices for production of brachytherapy seeds

    International Nuclear Information System (INIS)

    Mattos, Fabio R.; Rostelato, Maria Elisa C.M.; Zeituni, Carlos A.; Souza, Carla D.; Moura, Joao A.; Peleias Junior, Fernando S.; Karan Junior, Dib; Feher, Anselmo; Oliveira, Tiago B.; Benega, Marcos A.G.

    2013-01-01

    Ophthalmic tumors treatment with brachytherapy sources has been widely used as a primary or secondary therapy for non-malignant or malignant tumors, for example, choroid melanoma, and retinoblastoma. Ruthenium-106, Iodine-125, Palladium -103, Gold-198 and Iridium-192, are some radionuclides that can be applied for treatment of ocular tumors. These sources are in small sizes (a few millimeters) and different shapes (rods, wires, disks). To ensure high accuracy during treatment, they are positioned in eye applicators, specially designed to fit on the surface of tumor. The Nuclear and Energy Research Institute (IPEN/CNEN) in a partnership with Paulista Medicine School (UNIFESP) created a project that aims to develop a prototype of Iridium-192 seeds for treatment of eye cancer. This seed consists in a core of Ir -Pt alloy (20%-80%) with a length of 3 mm, to be activated in IPEN's IEA-R1 Reactor, and a titanium capsule sealing the core. It was imperative to develop a sustainer device for irradiation. This piece is used to avoid overlapping of one cores and, therefore, avoiding the 'shadow effect' that does not allow full activation of each core due to the high density. (author)

  17. Water equivalent phantom materials for 192Ir brachytherapy

    Science.gov (United States)

    Schoenfeld, Andreas A.; Harder, Dietrich; Poppe, Björn; Chofor, Ndimofor

    2015-12-01

    Several solid phantom materials have been tested regarding their suitability as water substitutes for dosimetric measurements in brachytherapy with 192Ir as a typical high energy photon emitter. The radial variations of the spectral photon fluence, of the total, primary and scattered photon fluence and of the absorbed dose to water in the transversal plane of the tested cylindrical phantoms surrounding a centric and coaxially arranged Varian GammaMed afterloading 192Ir brachytherapy source were Monte-Carlo simulated in EGSnrc. The degree of water equivalence of a phantom material was evaluated by comparing the radial dose-to-water profile in the phantom material with that in water. The phantom size was varied over a large range since it influences the dose contribution by scattered photons with energies diminished by single and multiple Compton scattering. Phantom axis distances up to 10 cm were considered as clinically relevant. Scattered photons with energies reaching down into the 25 keV region dominate the photon fluence at source distances exceeding 3.5 cm. The tested phantom materials showed significant differences in the degree of water equivalence. In phantoms with radii up to 10 cm, RW1, RW3, Solid Water, HE Solid Water, Virtual Water, Plastic Water DT, and Plastic Water LR phantoms show excellent water equivalence with dose deviations from a water phantom not exceeding 0.8%, while Original Plastic Water (as of 2015), Plastic Water (1995), Blue Water, polyethylene, and polystyrene show deviations up to 2.6%. For larger phantom radii up to 30 cm, the deviations for RW1, RW3, Solid Water, HE Solid Water, Virtual Water, Plastic Water DT, and Plastic Water LR remain below 1.4%, while Original Plastic Water (as of 2015), Plastic Water (1995), Blue Water, polyethylene, and polystyrene produce deviations up to 8.1%. PMMA plays a separate role, with deviations up to 4.3% for radii not exceeding 10 cm, but below 1% for radii up to 30 cm. As suggested by

  18. Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data

    Energy Technology Data Exchange (ETDEWEB)

    Zourari, K.; Peppa, V.; Papagiannis, P., E-mail: ppapagi@phys.uoa.gr [Medical Physics Laboratory, Medical School, University of Athens, 75 Mikras Asias, 11527 Athens (Greece); Ballester, Facundo [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Siebert, Frank-André [Clinic of Radiotherapy, University Hospital of Schleswig-Holstein, Campus Kiel 24105 (Germany)

    2014-04-15

    Purpose: To provide a method for calculating the transmission of any broad photon beam with a known energy spectrum in the range of 20–1090 keV, through concrete and lead, based on the superposition of corresponding monoenergetic data obtained from Monte Carlo simulation. Methods: MCNP5 was used to calculate broad photon beam transmission data through varying thickness of lead and concrete, for monoenergetic point sources of energy in the range pertinent to brachytherapy (20–1090 keV, in 10 keV intervals). The three parameter empirical model introduced byArcher et al. [“Diagnostic x-ray shielding design based on an empirical model of photon attenuation,” Health Phys. 44, 507–517 (1983)] was used to describe the transmission curve for each of the 216 energy-material combinations. These three parameters, and hence the transmission curve, for any polyenergetic spectrum can then be obtained by superposition along the lines of Kharrati et al. [“Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities,” Med. Phys. 34, 1398–1404 (2007)]. A simple program, incorporating a graphical user interface, was developed to facilitate the superposition of monoenergetic data, the graphical and tabular display of broad photon beam transmission curves, and the calculation of material thickness required for a given transmission from these curves. Results: Polyenergetic broad photon beam transmission curves of this work, calculated from the superposition of monoenergetic data, are compared to corresponding results in the literature. A good agreement is observed with results in the literature obtained from Monte Carlo simulations for the photon spectra emitted from bare point sources of various radionuclides. Differences are observed with corresponding results in the literature for x-ray spectra at various tube potentials, mainly due to the different broad beam conditions or x-ray spectra assumed. Conclusions

  19. Measurement of radiation exposures to the radiotherapists in the brachytherapy

    International Nuclear Information System (INIS)

    Matsuoka, Yoshisuke; Tsujii, Hirohiko; Mizoe, Junetsu

    1986-01-01

    Radiation exposures to the radiotherapists during brachytherapy with Iridium and Cesium were measured. For which TLD and pocket chamber were used. The materials were 30 patients, 14 of whom were treated by Iridium, and other 16 patients were treated by Cesium, from November 1983 to June 1984. The procedures of brachytherapy were divided into three parts: preparation, insertion, and withdrawal. In the Iridium therapy, 7 patients were treated for lesions in bile duct and in the Cesium therapy 13 patients were treated for lesions in head and neck. In the Iridium therapy the mean radiation exposures to the chest were 12.3 mrem, 177 mrem to the fingers, 9.6 mrem to the abdomen, 13.6 mrem to the head. In the Cesium therapy the mean radiation exposures to the chest were 49.4 mrem. 292 mrem to the fingers, 18.3 mrem to the abdomen, 49.4 mrem to the head. Thus, radiation exposures in the Iridium therapy were lower than those in the Cesium therapy in each sites of measurement. This could be because, in the Iridium therapy, afterloading procedure were used and the energy of Iridium gammar-ray is lower then that of Cesium gammar-ray and protection boards could be more effective in the Iridium therapy, than in the Cesium therapy. We analized radiation exposures according to the amount of sources, which are divided into two groups, 10 - 39 Cs. Eq. mCi (3.7 x 10 - 1.4 x 10 Cs. Eq. Bq) and 40 - 80 Cs. Eq. mCi (1.5 x 10 - 3.0 x 10 Cs. Eq. Bq). In the source runging 40 - 80 Cs. Eq. mCi, radiation exposures to the fingers in the Iridium therapy were almost the same as those in the Cesium therapy. When head and neck were treated radiation exposures to the fingers in the Iridium therapy were higher than those in the Cesium therapy. Therefore more effort should be pain to reduce radiation exposures to the fingers in the iridium therapy, especialy in assembling procedure. (author)