WorldWideScience

Sample records for intraoral bilateral con

  1. Effect of an intraoral retrusion plate on maxillary arch dimensions in complete bilateral cleft lip and palate patients

    NARCIS (Netherlands)

    Oosterkamp, B.C.; van Oort, R.P.; Dijkstra, P.U.; Stellingsma, K.; Bierman, M.W.; de Bont, L.G.

    Objective: The aim of this study was to analyze maxillary arch dimensions in patients with complete bilateral cleft lip and palate treated with an intraoral retrusion plate prior to lip closure. Patients: The effects of the intraoral retrusion plate were evaluated on serially obtained maxillary

  2. Tratamiento conservador en pacientes con retinoblastoma bilateral

    Directory of Open Access Journals (Sweden)

    Juan C. Suárez

    2008-11-01

    Full Text Available OBJETIVO: comparar el tratamiento convencional del retinoblastoma bilateral, usado hasta hace algunos años, consistente en radioterapia o enucleación bilateral, con el tratamiento conservador actual que incluye termoterapia transpupilar (TTT o TTT/quimioterapia al menos en un ojo, en niños con diagnóstico de retinoblastoma bilateral. DISEÑO: estudio retrospectivo descriptivo. MUESTRA: 20 pacientes con diagnóstico de retinoblastoma bilateral que consultaron al Hospital Universitario San Vicente de Paúl, de Medellín, Colombia, entre 1997 y 2007. MÉTODO: se hizo enucleación del ojo con el tumor de mayor tamaño. En el otro ojo se hizo tratamiento con TTT, con el láser diodo (810 nm, spot amplio, solo o combinado con otras terapias. RESULTADOS: se dividió a los pacientes en dos grupos: 16 pacientes (32 ojos en el grupo 1 tratados conservadoramente y 4 pacientes (8 ojos en el grupo 2 con tratamiento convencional. El rango de edad fue de 1-72 meses en el grupo 1 y de 1-12 meses en el grupo 2. El tiempo de seguimiento fue de 7-67 meses para el grupo 1 y de 13-73 meses para el grupo 2. En el grupo 1 se hizo enucleación de 16 ojos (50%, radioterapia externa de uno (3,1%, quimioterapia más termoterapia de 5 (15,6% y quimioterapia más termoterapia más crioterapia de 10 (31,3%. En todos los pacientes se logró preservar al menos un ojo. En el grupo 2, se enuclearon 7 ojos (87,5% y se hizo radioterapia externa más enucleación en un paciente (12.5%. Además, todos los pacientes recibieron quimioterapia. CONCLUSIÓN: la terapia conservadora actual consistente en tratamiento local (termoterapia, crioterapia o braquiterapia y quimiorreducción permite preservar al menos un ojo y en algunos casos de los dos, muchas veces con buena agudeza visual, en niños con retinoblastoma bilateral; se evitan así la enucleación bilateral y la radioterapia externa usada en el tratamiento convencional con todos sus efectos secundarios. La enucleación contin

  3. Avance maxilar en pacientes fisurados labio palatinos con distractor intraoral

    Directory of Open Access Journals (Sweden)

    Adoración Martínez Plaza

    2015-07-01

    Conclusiones: La DO intraoral es una técnica alternativa exitosa para avance del maxilar en pacientes fisurados labio palatinos que necesiten un avance inferior a 10 mm. Produce mejoras en el perfil esquelético y blando. Los dispositivos internos no producen impacto psicológico. La contención más larga en el tiempo. La recidiva es difícil de definir y calcular.

  4. Surgical Resolution of Bilateral Hypertrophy of Masseter Muscle Through Intraoral Approach.

    Science.gov (United States)

    Trento, Guilherme Dos Santos; Benato, Leonardo Silva; Rebellato, Nelson Luis Barbosa; Klüppel, Leandro Eduardo

    2017-06-01

    Masseter muscle hypertrophy is an untypical anomaly with no definite cause and its diagnosis is easily completed through physical examination and imaging examinations. In some cases, patient may report signs and symptoms of well-localizated pain. However, it is generally asymptomatic and patient's chief complaint is about esthetic because of facial asymmetry. In this case, surgery is carefully indicated. The aim of this article is to report a case of a male patient with no painful and functional complaints but an important unease over his facial asymmetry. Patient underwent surgery involving bilateral resection of mandibular angles and unilateral resection of masseter muscle through intraoral approach. Surgical approaches and techniques rely heavily on surgeon. There are few reports in the literature about this anomaly, but those available present several techniques. The surgeon's dexterity and knowledge become extremely important, whereas this procedure is essentiallyesthetic.

  5. Pros and cons of immediately sequential bilateral cataract surgery (ISBCS).

    Science.gov (United States)

    Grzybowski, Andrzej; Wasinska-Borowiec, Weronika; Claoué, Charles

    2016-01-01

    Immediately sequential bilateral cataract surgery (ISBCS) is currently a "hot topic" in ophthalmology. There are well-documented advantages in terms of quicker visual rehabilitation and reduced costs. The risk of bilateral simultaneous endophthalmitis and bilateral blindness is now recognized to be minuscule with the advent of intracameral antibiotics and modern management of endophthalmitis. Refractive surprises are rare for normal eyes and with the use of optical biometry. Where a general anesthetic is indicated for cataract surgery, the risk of death from a second anesthetic is much higher than the risk of blindness. A widely recognized protocol from the International Society of Bilateral Cataract Surgeons needs to be adhered to if surgeons wish to start practicing ISBCS.

  6. Bilateral adrenalectomy for Cushing's syndrome: Pros and cons

    Directory of Open Access Journals (Sweden)

    O P Prajapati

    2015-01-01

    Full Text Available Aim: To assess the outcome of patients undergoing bilateral adrenalectomy for Cushing's syndrome (CS. Methods: All patients who underwent bilateral adrenalectomy for CS at the Department of Endocrine Surgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences hospital between 1991 and 2013 were included. Medical records were reviewed to obtain patient characteristics and follow-up data. Results: Twenty-seven patients were studied. Mean age was 28.74 ± 12.95 years (range 9–60, male:female ratio was 1.7:1. About half that is, 48.19% were of Cushing's disease (failed trans-sphenoidal surgery [TSS], 37.04% were of ectopic CS (ECS, and 14.81% were of CS due to bilateral adrenal pathology. Median follow-up period was 80.5 months. Before surgery, 74.1% patients had body mass index > which after surgery declined to <25 in 75% of them. Hypertension was present in 85.2% and after surgery resolved in 40%. Diabetes mellitus was present in 44.4% and after surgery resolved in 33% of them. Hirsutism and proximal muscle weakness were present in 55.6% and 70.4% patients, respectively, and after surgery improved markedly in all patients. Adrenal crisis developed in 36.3% and Nelson's syndrome in 41.7% patients during follow-up. Three patients died in perioperative period while three succumbed to the disease during follow-up. Two patients developed recurrence of endogenous cortisol production during the follow-up period. Conclusions: Bilateral adrenalectomy is a valid treatment option for palliating severe symptoms in Pituitary Cushing's with failed TSS and unlocalized ECS but the procedure is curative for CS due to bilateral adrenal disease. Overall morbidity and mortality is higher than other endocrine operations. Co-morbidities tend to be more severe and are a risk factor for mortality during the time patient survives.

  7. Celulitis orbitaria bilateral con endoftalmitis en una paciente con reciente diagnóstico de diabetes mellitus tipo 2

    OpenAIRE

    Farrell González, Lesley; Ezpeleta Rodríguez, Mayra M.; Sierra Garcia, Carlos; Mayer Rivera, Francisco

    2014-01-01

    Se presentó una mujer de 74 años al servicio de urgencias del HRAEBI, ISSSTE, el día 2 de septiembre de 2010 con datos de desequilibrio hidroelectrolítico, hipotensión y conjuntivitis bilateral. Sus signos vitales durante su estancia en urgencias fueron: tensión arterial, 80/40 mmHg; temperatura, 38.5 °C; frecuencia respiratoria, 22 rpm; frecuencia cardíaca 89 lpm Se interconsulta al servicio de Oftalmología quienes diagnosticaron celulitis orbitaria bilateral, con no percepción de luz en amb...

  8. Celulitis orbitaria bilateral con endoftalmitis en una paciente con reciente diagnóstico de diabetes mellitus tipo 2

    Directory of Open Access Journals (Sweden)

    Lesley Farrell González

    2014-07-01

    Full Text Available Se presentó una mujer de 74 años al servicio de urgencias del HRAEBI, ISSSTE, el día 2 de septiembre de 2010 con datos de desequilibrio hidroelectrolítico, hipotensión y conjuntivitis bilateral. Sus signos vitales durante su estancia en urgencias fueron: tensión arterial, 80/40 mmHg; temperatura, 38.5 °C; frecuencia respiratoria, 22 rpm; frecuencia cardíaca 89 lpm Se interconsulta al servicio de Oftalmología quienes diagnosticaron celulitis orbitaria bilateral, con no percepción de luz en ambos ojos e igualmente ausencia de reflejos pupilares. Se inició tratamiento con antibióticos intravenosos y se solicitó tomografía computarizada de órbitas y cerebro. Se internó para estabilizar su estado general; durante su estancia se diagnosticó diabetes mellitus y estado inmunosupresivo por datos de candidiasis oral y otros síntomas. La tomografía mostró celulitis orbitaria bilateral con formación de abscesos orbitarios, sin datos de proceso infeccioso a nivel bucal o de senos paranasales. La evolución de la celulitis fue tórpida a pesar de la terapia antibiótica cuádruple (cefotaxima, vancomicina, metronidazol y clindamicina; posteriormente imipenem, clindamicina y vancomicina con desarrollo de endoftalmitis bilateral por lo cual fue necesario eviscerar ambos ojos. Se tomó cultivo directo del vítreo y 3 días después se encontró como germen causal Klebsiella pneumoniae.

  9. Queratitis ulcerativa periférica bilateral en paciente con artritis reumatoide: tratamiento con infliximab

    Directory of Open Access Journals (Sweden)

    Vicente Aldasoro-Cáceres

    2017-01-01

    Discusión: La PUK es una enfermedad rara, pero a tener en cuenta en los pacientes con AR. En la mayoría de los casos, el tratamiento de fondo debe ser intensificado; en este sentido deben considerarse los tratamientos biológicos por su eficacia y efecto rápido de acción.

  10. Necrosis Avascular Bilateral de cadera en paciente con VIH y traumatismo de arma de fuego.

    Directory of Open Access Journals (Sweden)

    Belkis J Menoni Blanco

    2011-01-01

    Full Text Available La Necrosis Avascular de Cadera (NAV es un proceso patológico infrecuente, originado por faltade irrigación de la articulación coxofemoral que implica necrosis y degeneración de los huesos que la conforman, causando dolor e impotencia funcional. Es más frecuente en varones jóvenes, pudiendo ser unilateral o bilateral. La etiología puede ser idiopática o estar relacionada a causas sistémicas como infección por VIH y su tratamiento depende de la severidad. En este reporte, se presenta un caso masculino de 35 años, seropositivo con tratamiento antirretroviral y antecedente de herida por arma de fuego de presentación inusual en cadera, sin lesión ósea aparente; quien refiere dolor de cadera izquierda, de fuerte intensidad, punzante, irradiado a rodilla izquierda, que produce limitación funcional. Al examen físico se evidencia marcha de Trendelemburg, con signos de Thomas y Patrick positivos. La radiografía demuestra NAV tipo Ficat-Arlet IV y es corregida mediante artroplastia total de cadera izquierda. Palabras claves: Necrosis Avascular de Cabeza de Fémur, VIH, Herida por arma de fuego.

  11. Necrosis Avascular Bilateral de cadera en paciente con VIH y traumatismo de arma de fuego.

    Directory of Open Access Journals (Sweden)

    Belkis J. Menoni Blanco

    2009-01-01

    Full Text Available La Necrosis Avascular de Cadera (NAV es un proceso patológico infrecuente, originado por falta de irrigación de la articulación coxofemoral que implica necrosis y degeneración de los huesos que la conforman, causando dolor e impotencia funcional. Es más frecuente en varones jóvenes, pudiendo ser unilateral o bilateral. La etiología puede ser idiopática o estar relacionada a causas sistémicas como infección por VIH y su tratamiento depende de la severidad. En este reporte, se presenta un caso masculino de 35 años, seropositivo con tratamiento antirretroviral y antecedente de herida por arma de fuego de presentación inusual en cadera, sin lesión ósea aparente, quien refiere dolor de cadera izquierda, de fuerte intensidad, punzante, irradiado a rodilla izquierda, que produce limitación funcional. Al examen físico se evidencia marcha de Trendelemburg, con signos de Thomas y Patrick positivos. La radiografía demuestra NAV tipo Ficat-Arlet IV y es corregida mediante artroplastia total de cadera izquierda.

  12. Intraoral gothic arch tracing.

    Science.gov (United States)

    Rubel, Barry; Hill, Edward E

    2011-01-01

    In order to create optimum esthetics, function and phonetics in complete denture fabrication, it is necessary to record accurate maxillo-mandibular determinants of occlusion. This requires clinical skill to establish an accurate, verifiable and reproducible vertical dimension of occlusion (VDO) and centric relation (CR). Correct vertical relation depends upon a consideration of several factors, including muscle tone, inter-dental arch space and parallelism of the ridges. Any errors made while taking maxillo-mandibular jaw relation records will result in dentures that are uncomfortable and, possibly, unwearable. The application of a tracing mechanism such as the Gothic arch tracer (a central bearing device) is a demonstrable method of determining centric relation. Intraoral Gothic arch tracers provide the advantage of capturing VDO and CR in an easy-to-use technique for practitioners. Intraoral tracing (Gothic arch tracing) is a preferred method of obtaining consistent positions of the mandible in motion (retrusive, protrusive and lateral) at a comfortable VDO.

  13. Intraoral giant condyloma acuminatum

    Directory of Open Access Journals (Sweden)

    Gupta R

    2001-09-01

    Full Text Available A case of intraoral giant condyloma acuminatum is reported in a 50- year- old Indian. He did not respond to topical application of podophyllin 20% but responded partially to electric cauterisation. Surgical excision was done to get rid of the warty growh completely. Since there were no skin or genital lesions and no history of marital or extramarital sexual contact the lesion was probably acquired from environmental sources. Nonsexual transmission should be considered especially when the lesions are extragenital.

  14. Presentation of Apocrine Breast Carcinoma in a Woman with Bilateral Silicone Prosthesis; Presentacion de un carcinoma apocrino de mama en una mujer con protesis bilateral de silicona

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, J. A.; Salvador, R.; Salvador, M.; Barranco, C.

    2003-07-01

    We present a case of apocrine breast carcinoma in a 45 year-old woman with bilateral silicone breast prosthesis whose clinical manifestations and mammography were that of a palpable nodule-high glandular density, rounded and with imprecise borders devoid of any visible microcalcifications. A bibliographical revision confirmed the infrequent association of this type of tumor with the presence of silicone breast implants, precisely in which we consider its radiological interest to lie. (Author) 11 refs.

  15. Hernias inguinales bilaterales operadas con anestesia local mediante hernioplastia de Lichtenstein Bilateral inguinal hernias operated on with local anesthesia by Lichtenstein hernioplasty

    Directory of Open Access Journals (Sweden)

    Bárbaro Agustín Armas Pérez

    2009-03-01

    Full Text Available INTRODUCCIÓN. La hernioplastia inguinal bilateral libre de tensión de Lichtenstein es una posibilidad real de tratamiento en pacientes con hernia inguinal bilateral. Este método es en esencia menos costoso para el paciente, la institución y la economía en general, y permite una reincorporación rápida a la sociedad, por lo cual en el presente estudio se presentaron los resultados de este protocolo de tratamiento, con la finalidad de evaluar su efectividad. MÉTODOS. Se realizó un estudio descriptivo transversal con los primeros 38 pacientes operados con la técnica de Lichtenstein mediante anestesia local (técnica combinada de Braun y de Shleider. Los pacientes fueron operados de forma ambulatoria entre enero de 2001 y diciembre del 2007. Se dio el alta en la tarde, si la operación fue en la mañana; y al amanecer del día siguiente, si se operó en la tarde, con el objetivo de evitar la equimosis declive con la movilización precoz. RESULTADOS. Cuatro de los pacientes presentaban hernias recurrentes. El material protésico más empleado fue el polipropileno (86,9 %. Las complicaciones alcanzaron el 9,1 % (referidas no a los 38 pacientes, sino a las 76 hernioplastias; y después de un seguimiento que osciló entre 1 y 36 meses, se presentó un rechazo al material protésico (1,3 % y una recidiva (1,3 %. CONCLUSIONES. Se concluyó que este procedimiento es aplicable a las hernias bilaterales, ya que el estrés, los costos institucionales y las molestias del paciente se reducen, con lo cual demuestra su eficacia.INTRODUCTION. Lichtenstein's tension free bilateral inguinal hernioplasty is a real possibility for treating patients with bilateral inguinal hernia. This method is essentially less expensive for the patient, the institution and the economy in general, and it allows a fast reincorporation to society. Therefore, the results of this treatment protocol were included in the present study aimed at evaluating its effectiveness. METHODS

  16. Diseño y construcción de un expansor de paladar para niños con labio fisurado y paladar hendido de tipo bilateral

    Directory of Open Access Journals (Sweden)

    Jaime Echeverri A.

    2004-01-01

    Full Text Available este artículo presenta una posible solución a uno de los problemas de tipo congénito que con más frecuencia se presenta en la población Colombiana: el labio fisurado y/o paladar hendido de tipo bilateral. Se muestran los factores de diseño y selección del material para la construcción de un expansor de paladar diseñado de acuerdo a las condiciones de nuestra población.

  17. Accuracy of five intraoral scanners compared to indirect digitalization.

    Science.gov (United States)

    Güth, Jan-Frederik; Runkel, Cornelius; Beuer, Florian; Stimmelmayr, Michael; Edelhoff, Daniel; Keul, Christine

    2017-06-01

    Direct and indirect digitalization offer two options for computer-aided design (CAD)/ computer-aided manufacturing (CAM)-generated restorations. The aim of this study was to evaluate the accuracy of different intraoral scanners and compare them to the process of indirect digitalization. A titanium testing model was directly digitized 12 times with each intraoral scanner: (1) CS 3500 (CS), (2) Zfx Intrascan (ZFX), (3) CEREC AC Bluecam (BLU), (4) CEREC AC Omnicam (OC) and (5) True Definition (TD). As control, 12 polyether impressions were taken and the referring plaster casts were digitized indirectly with the D-810 laboratory scanner (CON). The accuracy (trueness/precision) of the datasets was evaluated by an analysing software (Geomagic Qualify 12.1) using a "best fit alignment" of the datasets with a highly accurate reference dataset of the testing model, received from industrial computed tomography. Direct digitalization using the TD showed the significant highest overall "trueness", followed by CS. Both performed better than CON. BLU, ZFX and OC showed higher differences from the reference dataset than CON. Regarding the overall "precision", the CS 3500 intraoral scanner and the True Definition showed the best performance. CON, BLU and OC resulted in significantly higher precision than ZFX did. Within the limitations of this in vitro study, the accuracy of the ascertained datasets was dependent on the scanning system. The direct digitalization was not superior to indirect digitalization for all tested systems. Regarding the accuracy, all tested intraoral scanning technologies seem to be able to reproduce a single quadrant within clinical acceptable accuracy. However, differences were detected between the tested systems.

  18. The Intraoral Ultrasonography in Dentistry | Caglayan | Nigerian ...

    African Journals Online (AJOL)

    Intraoral USG is also used in dentistry for examining the salivary glands and ducts, as well as the mouth floor, the buccal, labial, and palatal mucosa, the tongue, periodontal tissues, and periapical lesions. The main purpose of this review is to provide detailed information about intraoral USG applications in dentistry.

  19. The CT appearance of intraoral chewing gum

    International Nuclear Information System (INIS)

    Towbin, Alexander J.

    2008-01-01

    When imaged, intraoral chewing gum has the potential to be misdiagnosed. Chewing gum has a characteristic appearance on CT: it is ovoid in shape, hyperdense, and has small internal locules of air. Reports have described the appearance of gum on radiographs and abdominal CT images; however, no reports could be found detailing its appearance within the mouth. This report describes the appearance of intraoral chewing gum as well as the properties of the gum that lead to this appearance. Because of the potential for misdiagnosis, screening for intraoral foreign bodies should be considered prior to imaging. (orig.)

  20. The CT appearance of intraoral chewing gum

    Energy Technology Data Exchange (ETDEWEB)

    Towbin, Alexander J. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2008-12-15

    When imaged, intraoral chewing gum has the potential to be misdiagnosed. Chewing gum has a characteristic appearance on CT: it is ovoid in shape, hyperdense, and has small internal locules of air. Reports have described the appearance of gum on radiographs and abdominal CT images; however, no reports could be found detailing its appearance within the mouth. This report describes the appearance of intraoral chewing gum as well as the properties of the gum that lead to this appearance. Because of the potential for misdiagnosis, screening for intraoral foreign bodies should be considered prior to imaging. (orig.)

  1. Intraoral frostbite and Leidenfrost effect.

    Science.gov (United States)

    Divya, V C; Saravanakarthikeyan, B

    2018-04-21

    Current lifestyle trends encouraging the rise in use of liquid nitrogen in food and beverages may eventually increase the episodes of injuries reported as well. Here, we report the first case of intraoral frostbite as a result of direct injury to the tissues due to ingestion of liquid nitrogen. The mechanism of injury to the oral mucosa in the absence of any injury to the gastric mucosa is explained correlating it to the Leidenfrost phenomenon. Awareness and proper regulations for the use of liquid nitrogen are unavailable and must be created in order to avoid any potential mortality. The diagnostician must consider the possibility of a chemical agent such as liquid nitrogen, which is so widely being used in the food and beverage industry, as a possible aetiological factor of oral mucosal injury. © 2018 Australian Dental Association.

  2. Revisión sistemática del linfoma plasmablástico intraoral en paciente con virus de la inmunodeficiencia humana. A propósito de un caso

    Directory of Open Access Journals (Sweden)

    Estefanía Alvarez

    2018-04-01

    Full Text Available Resumen: Los linfomas son los tumores no epiteliales malignos más frecuente en la cavidad oral y región maxilofacial. El riesgo de los pacientes con VIH de presentar esta enfermedad es 200 veces mayor en comparación con la población general. El linfoma plasmablástico es una neoplasia agresiva poco frecuente. La clasificación del 2008 de la OMS lo define como una proliferación difusa de células grandes neoplásicas semejantes a inmunoblastos B con inmunofenotipo de células plasmáticas, con la mayoría de los casos asociados a pacientes con VIH. El propósito de este artículo es presentar una revisión sistemática de esta enfermedad junto a un caso clínico de difícil diagnóstico por su expresión clínica, en el que el estudio histopatológico fue determinante. Abstract: Lynphomas are the most common malignant non-epithelial tumours in the oral cavity and maxilofacial región. The risk of HIV patients presenting with this condition is 200 times more compared to the general population. Plasmablastic lymphoma is a rare aggresive neoplasm. The WHO 2008 classification defines it as a diffuse proliferation of large neoplastic cells, such as B immunoblasts with plasma inmunophenotype cells, with most cases being associated with HIV patients. The purpose of this article is to present a systematic review of this pathology together with a case of difficult diagnosis due to its clinical expression, and in which the histopathology study was decisive. Palabras clave: Linfoma plasmablástico, Virus de la inmunodeficiencia humana, Neoplasia, Keywords: Plasmablastic lynphoma, Human inmunodefiency virus, Neoplasm

  3. Intraoral scanning systems - a current overview.

    Science.gov (United States)

    Zimmermann, M; Mehl, A; Mörmann, W H; Reich, S

    2015-01-01

    There is no doubt today about the possibilities and potential of digital impression-taking with the aid of intraoral optical impression systems, and the past few years have seen a considerable increase in the range of optical intraoral scanners available on the market. On the strength of numerous innovations and a wider range of indications in orthodontics and implantology, intraoral scanning systems appear to be a highly promising development for the future. Digital impression-taking with intraoral scanners has already shown itself in some respects to be clearly superior to conventional impression- taking. Particularly worthy of mention is the versatile integration of digital impressions into diagnostic and treatment concepts to provide a customizable healthcare solution for the patient. It remains exciting to look forward to future developments that will allow us to observe digital impression-taking--as with other digital applications already established in everyday life--becoming firmly established in the routine of dentistry and dental technology. This article presents an overview of the benefits and limitations of digital impression-taking using intraoral scanning systems, and includes a summary of all the relevant intraoral scanners available on the market at present.

  4. Mutations in CFTR gene and clinical correlation in Argentine patients with congenital bilateral absence of the vas deferens Correlación de las características clínicas con mutaciones del gen CFTR en pacientes argentinos con ausencia bilateral congénita de vasos deferentes

    Directory of Open Access Journals (Sweden)

    Estrella M Levy

    2004-06-01

    Full Text Available Congenital bilateral absence of the vas deferens (CBAVD is a form of male infertility in which mutations in the cystic fibrosis transmembrane conductance regulator (CFTR gene have been identified. Here we identify different mutations of CFTR and the poly-T variant of intron 8 (IVS8 in Argentine patients and analyze sweat test values and clinical characteristic related to Cystic Fibrosis (CF. For counseling purposes the two most frequent mutations in Argentine CF population: DF508 and G542X were screened in wives. In all cases, it was possible to reduce the risk of CF/CBAVD descendants in these couples because none of the mutation were found in the 36 samples. Eight patients (23% showed abnormal chloride values (> 60 mmol/l. A second group of 6 patients (18% had borderline values of sweat chloride (40-59 mmol/l. We defined another group with 6 patients (18%, with normal sweat chloride levels (30-39 mmo/l and a fourth group of 14 (41% patients with sweat chloride below 30 mmol/l. DF508, the most frequent CF mutation in the Argentine population, was found on 15 of the 72 chromosomes (21%, R117H mutation was detected on 2 of 62 chromosomes (3%. Only one R347P allele was found on 28 chromosomes analyzed (2%. On a sample of 27 patients, IVS8 analysis showed a frequency of 6/56 chromosomes (11% of 5T allele. Even though these findings present an improvement in the detection of mutations related to clinical correlations in Argentine CBAVD population, the search for other common and uncommon mutations should be continued.La ausencia bilateral congénita de vasos deferentes (CBAVD es una forma de infertilidad masculina en la que se han identificado mutaciones en el gen de la conductancia transmembrana de la fibrosis quística (CFTR. Hemos estudiado en pacientes argentinos diferentes mutaciones en el CFTR y la variante poli T del intron 8 (IVS8 y analizado los valores de test del sudor y las características clínicas relacionadas a la Fibrosis Qu

  5. A comparison of the accuracy of intraoral scanners using an intraoral environment simulator.

    Science.gov (United States)

    Park, Hye-Nan; Lim, Young-Jun; Yi, Won-Jin; Han, Jung-Suk; Lee, Seung-Pyo

    2018-02-01

    The aim of this study was to design an intraoral environment simulator and to assess the accuracy of two intraoral scanners using the simulator. A box-shaped intraoral environment simulator was designed to simulate two specific intraoral environments. The cast was scanned 10 times by Identica Blue (MEDIT, Seoul, South Korea), TRIOS (3Shape, Copenhagen, Denmark), and CS3500 (Carestream Dental, Georgia, USA) scanners in the two simulated groups. The distances between the left and right canines (D3), first molars (D6), second molars (D7), and the left canine and left second molar (D37) were measured. The distance data were analyzed by the Kruskal-Wallis test. The differences in intraoral environments were not statistically significant ( P >.05). Between intraoral scanners, statistically significant differences ( P Kruskal-Wallis test with regard to D3 and D6. No difference due to the intraoral environment was revealed. The simulator will contribute to the higher accuracy of intraoral scanners in the future.

  6. Design of a technique for the radiotherapy treatment of patients of prostate with bilateral prosthetic hip; Diseno de una tecnica para el tratamiento radioterapico de pacientes de prostata con protesis bilateral de cadera

    Energy Technology Data Exchange (ETDEWEB)

    Camacho, C.; Perez-Alija, J.; Olivares, S.; Loscos, S.; Pedro, A.

    2013-07-01

    The design of the plan of treatment of patients who have to undergo radical radiotherapy of prostate and that incorporate some sort of hip prosthesis is usually complex. the case of a patient's prostatic bed with bilateral hip prosthesis to assess radical radiotherapy to the 70Gy in bed. The objective of this paper is to present the chosen technique designed for this treatment. (Author)

  7. Mandibular Movement Restoration in a Child with Bilateral Coronoid Hyperplasia: A Case Report

    Directory of Open Access Journals (Sweden)

    Danica Popovik Monevska

    2016-04-01

    CONCLUSIONS: The article presents a clinical and surgical case of bilateral coronoidectomy in a 3-year-old girl, with retrognathic mandible. The diagnosis of bilateral coronoid process hyperplasia was confirmed, and the surgical treatment was under general anesthesia, with nasotracheal intubation guided by a nasofiber endoscope, using an intraoral approach.

  8. Stationary intraoral tomosynthesis for dental imaging

    Science.gov (United States)

    Inscoe, Christina R.; Wu, Gongting; Soulioti, Danai E.; Platin, Enrique; Mol, Andre; Gaalaas, Laurence R.; Anderson, Michael R.; Tucker, Andrew W.; Boyce, Sarah; Shan, Jing; Gonzales, Brian; Lu, Jianping; Zhou, Otto

    2017-03-01

    Despite recent advances in dental radiography, the diagnostic accuracies for some of the most common dental diseases have not improved significantly, and in some cases remain low. Intraoral x-ray is the most commonly used x-ray diagnostic tool in dental clinics. It however suffers from the typical limitations of a 2D imaging modality including structure overlap. Cone-beam computed tomography (CBCT) uses high radiation dose and suffers from image artifacts and relatively low resolution. The purpose of this study is to investigate the feasibility of developing a stationary intraoral tomosynthesis (s-IOT) using spatially distributed carbon nanotube (CNT) x-ray array technology, and to evaluate its diagnostic accuracy compared to conventional 2D intraoral x-ray. A bench-top s-IOT device was constructed using a linear CNT based X-ray source array and a digital intraoral detector. Image reconstruction was performed using an iterative reconstruction algorithm. Studies were performed to optimize the imaging configuration. For evaluation of s-IOT's diagnostic accuracy, images of a dental quality assurance phantom, and extracted human tooth specimens were acquired. Results show s-IOT increases the diagnostic sensitivity for caries compared to intraoral x-ray at a comparable dose level.

  9. Efecto de 24 sesiones de entrenamiento de fuerza en un paciente con gonartrosis bilateral: a propósito de un caso

    Directory of Open Access Journals (Sweden)

    O. Abrahin

    2015-03-01

    Conclusión: Los resultados de este estudio indican que 24 sesiones de EF progresivo pueden ser eficaces en la mejora de índices antropométricos, la capacidad funcional y la fuerza muscular de un paciente anciano diagnosticado de GA bilateral.

  10. Evaluation of the Beam Quality of Intraoral X-ray Equipment using Intraoral Standard Films

    International Nuclear Information System (INIS)

    Lee, Sang Sub; Kwon, Hyok Rak; Sim, Woo Hyoun; Oh, Seung Hyoun; Lee, Ji Youn; Jeon, Kug Jin; Kim, Kee Deog; Park, Chang Seo

    2000-01-01

    This study was to evaluate the beam quality of intraoral X-ray equipment used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. The study was done using the intraoral X-ray equipment used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Most of the HVLs of intraoral X-ray equipment were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANPAS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X-ray equipment should be managed in the planned and organized fashion.

  11. Resultados a corto-medio plazo en revascularización miocárdica aislada con injerto de arteria mamaria interna bilateral en 497 pacientes

    Directory of Open Access Journals (Sweden)

    Carlos-Esteban Martín López

    2016-01-01

    Conclusiones: La cirugía de revascularización miocárdica con doble mamaria presenta unos excelentes resultados a corto y medio plazo independientemente de la edad. En pacientes con elevada comorbilidad, especialmente vasculopatía e insuficiencia renal, se debería individualizar la decisión del uso de doble mamaria.

  12. Reliability of intra-oral quantitative sensory testing (QST) in patients with atypical odontalgia and healthy controls - a multicentre study.

    Science.gov (United States)

    Baad-Hansen, L; Pigg, M; Yang, G; List, T; Svensson, P; Drangsholt, M

    2015-02-01

    The reliability of comprehensive intra-oral quantitative sensory testing (QST) protocol has not been examined systematically in patients with chronic oro-facial pain. The aim of the present multicentre study was to examine test-retest and interexaminer reliability of intra-oral QST measures in terms of absolute values and z-scores as well as within-session coefficients of variation (CV) values in patients with atypical odontalgia (AO) and healthy pain-free controls. Forty-five patients with AO and 68 healthy controls were subjected to bilateral intra-oral gingival QST and unilateral extratrigeminal QST (thenar) on three occasions (twice on 1 day by two different examiners and once approximately 1 week later by one of the examiners). Intra-class correlation coefficients and kappa values for interexaminer and test-retest reliability were computed. Most of the standardised intra-oral QST measures showed fair to excellent interexaminer (9-12 of 13 measures) and test-retest (7-11 of 13 measures) reliability. Furthermore, no robust differences in reliability measures or within-session variability (CV) were detected between patients with AO and the healthy reference group. These reliability results in chronic orofacial pain patients support earlier suggestions based on data from healthy subjects that intra-oral QST is sufficiently reliable for use as a part of a comprehensive evaluation of patients with somatosensory disturbances or neuropathic pain in the trigeminal region. © 2014 John Wiley & Sons Ltd.

  13. 21 CFR 872.4130 - Intraoral dental drill.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraoral dental drill. 872.4130 Section 872.4130...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4130 Intraoral dental drill. (a) Identification. An intraoral dental drill is a rotary device intended to be attached to a dental handpiece to drill holes in...

  14. 21 CFR 872.6890 - Intraoral dental wax.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraoral dental wax. 872.6890 Section 872.6890...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6890 Intraoral dental wax. (a) Identification. Intraoral dental wax is a device made of wax intended to construct patterns from which custom made metal...

  15. Reparación de hernias inguinoescrotales gigantes bilaterales con realización preoperatoria de neumoperitoneo Repair of bilateral giant inguinoscrotal hernias with preoperative pneumoperitoneum

    Directory of Open Access Journals (Sweden)

    Eugenio Vicario Benito del Valle

    2004-06-01

    Full Text Available Se describe el manejo preoperatorio y quirúrgico de un paciente con hernia inguinoescrotal gigante “con pérdida del derecho de asilo” mediante neumoperitoneo preoperatorio, con el fin de facilitar su reducción y evitar la tensión y la insuficiencia respiratoria que conllevaría. Para realizar el neumoperitoneo se utilizó el aparato de laparoscopia a través de un drenaje peritoneal colocado percutaneamente con ayuda del radiólogo intervencionistaThe preoperative and surgical management of a patient with giant inguinoscrotal hernia with “loss of the asylum right” by preoperative pneumoperitoneum in order to facilitate its reduction and prevent the tension and respiratory failure it would lead to, is described. The pneumoperitoneum was performed by using the laparoscopy apparatus through a peritoneal drainage percutaneously placed with the help of the interventionist radiologist

  16. Bilateral iatrogenic maxillary fractures after dental treatment in two aged horses

    OpenAIRE

    Widmer, A; Fürst, A; Bettschart-Wolfensberger, R; Makara, M; Geyer, H; Kummer, M

    2010-01-01

    This clinical report describes two horses with bilateral maxillary fractures following dental treatment. The fractures occurred during dental treatment by a veterinarian, and both had rostral, transverse, and complete bilateral maxillary fractures with instability and minimal displacement. The fractures were repaired using bilateral intraoral wiring with the patients under general anesthesia. The postoperative period was without complications and the fractures healed as expected. Maxillary fr...

  17. Bilateral pulmonary thromboembolism and Budd-Chiari syndrome in a patient with Crohn's disease on oral contraceptives Tromboembolismo de pulmón bilateral y síndrome de Budd-Chiari en paciente con enfermedad de Crohn y toma de anticonceptivos orales

    Directory of Open Access Journals (Sweden)

    M. Valdés Mas

    2009-09-01

    Full Text Available Budd-Chiari syndrome can be defined as an interruption or diminution of the normal blood flow out of the liver. Patients with Budd-Chiari syndrome present with varying degrees of symptomatology that can be divided into the following categories: fulminant, acute, subacute and chronic. The subacute form is the most common presentation. A majority of patients with Budd-Chiari syndrome have an underlying hypercoagulability state. We present the case of a young woman with Crohn's disease on oral contraceptives who developed bilateral pulmonary thromboembolism and Budd-Chiari syndrome.El síndrome de Budd-Chiari consiste en la interrupción o disminución de flujo de las venas suprahepáticas. Tiene una gran variabilidad clínica en cuanto a su forma de presentación siendo la más frecuente la forma subaguda. La gran mayoría de los pacientes responden a estados de hipercoagulabilidad. Presentamos el caso de una paciente joven con enfermedad de Crohn que estaba en tratamiento con anticonceptivos orales y desarrolló un cuadro clínico de tromboembolismo de pulmón bilateral y síndrome de Budd-Chiari.

  18. Intra-oral pressure-based voicing control of electrolaryngeal speech with intra-oral vibrator.

    Science.gov (United States)

    Takahashi, Hirokazu; Nakao, Masayuki; Kikuchi, Yataro; Kaga, Kimitaka

    2008-07-01

    In normal speech, coordinated activities of intrinsic laryngeal muscles suspend a glottal sound at utterance of voiceless consonants, automatically realizing a voicing control. In electrolaryngeal speech, however, the lack of voicing control is one of the causes of unclear voice, voiceless consonants tending to be misheard as the corresponding voiced consonants. In the present work, we developed an intra-oral vibrator with an intra-oral pressure sensor that detected utterance of voiceless phonemes during the intra-oral electrolaryngeal speech, and demonstrated that an intra-oral pressure-based voicing control could improve the intelligibility of the speech. The test voices were obtained from one electrolaryngeal speaker and one normal speaker. We first investigated on the speech analysis software how a voice onset time (VOT) and first formant (F1) transition of the test consonant-vowel syllables contributed to voiceless/voiced contrasts, and developed an adequate voicing control strategy. We then compared the intelligibility of consonant-vowel syllables among the intra-oral electrolaryngeal speech with and without online voicing control. The increase of intra-oral pressure, typically with a peak ranging from 10 to 50 gf/cm2, could reliably identify utterance of voiceless consonants. The speech analysis and intelligibility test then demonstrated that a short VOT caused the misidentification of the voiced consonants due to a clear F1 transition. Finally, taking these results together, the online voicing control, which suspended the prosthetic tone while the intra-oral pressure exceeded 2.5 gf/cm2 and during the 35 milliseconds that followed, proved efficient to improve the voiceless/voiced contrast.

  19. Cyanoacrylate for Intraoral Wound Closure: A Possibility?

    Directory of Open Access Journals (Sweden)

    Parimala Sagar

    2015-01-01

    Full Text Available Wound closure is a part of any surgical procedure and the objective of laceration repair or incision closure is to approximate the edges of a wound so that natural healing process may occur. Over the years new biomaterials have been discovered as an alternate to conventional suture materials. Cyanoacrylate bioadhesives are one among them. They carry the advantages of rapid application, patient comfort, resistance to infection, hemostatic properties, and no suture removal anxiety. Hence this study was undertaken to study the effect of long chain cyanoacrylate as an adhesive for intraoral wound closure and also to explore its hemostatic and antibacterial effects. Isoamyl-2-cyanoacrylate (AMCRYLATE was used as the adhesive in the study. In conclusion isoamyl cyanoacrylate can be used for intraoral wound closure, as an alternative to sutures for gluing the mucoperiosteum to bone, for example, after impaction removal, periapical surgeries, and cleft repair. Its hemostatic and antibacterial activity has to be further evaluated.

  20. Evaluation of occupational exposure in intraoral radiography

    International Nuclear Information System (INIS)

    Miguel, Cristiano; Barros, Frieda S.; Rocha, Anna S.P.S.; Godoi, Walmor C.; Tilly Junior, Joao G.

    2014-01-01

    The intraoral radiography is widely performed in the dental office due to low cost and agility. The doses in intraoral radiology are considered low, however it is known that doses below the threshold for deterministic radiation has the potential to induce stochastic effects. An intraoral radiography has a risk of inducing fatal cancer or serious in order of 1:10,000,000. Besides the patient, the dentist may also be being exposed to radiation during the work with the radiographics practices. The bibliographies demonstrates the lack of information on radiation protection of dentists, however, the occupational dose reduction was observed in radiology over the past 14 years. This work aims to evaluate the effective dose of radiation to which workers can be exposed dentists in dental offices to perform intraoral radiographs. In this context, a study was be conducted between June 2013 and May 2014 with 44 professionals in Curitiba city. For each dentist was given a personal dosimeter to be used for 30 days. During this period, the number of radiographies and the length of the cable triggers of the X-ray equipment was registered and, the dosimeter´s dose was read. It was observed that the cables triggers meet regulatory standards and allow dentists to get the mean minimum distance of two meters from the radiation source in 93% of cases. Through analysis of the doses, it was concluded that occupational exposures of these workers are within the recommended threshold by regulatory 453/1998 of the Ministry of Health from Brazil. (author)

  1. Complete-arch accuracy of intraoral scanners.

    Science.gov (United States)

    Treesh, Joshua C; Liacouras, Peter C; Taft, Robert M; Brooks, Daniel I; Raiciulescu, Sorana; Ellert, Daniel O; Grant, Gerald T; Ye, Ling

    2018-04-30

    Intraoral scanners have shown varied results in complete-arch applications. The purpose of this in vitro study was to evaluate the complete-arch accuracy of 4 intraoral scanners based on trueness and precision measurements compared with a known reference (trueness) and with each other (precision). Four intraoral scanners were evaluated: CEREC Bluecam, CEREC Omnicam, TRIOS Color, and Carestream CS 3500. A complete-arch reference cast was created and printed using a 3-dimensional dental cast printer with photopolymer resin. The reference cast was digitized using a laboratory-based white light 3-dimensional scanner. The printed reference cast was scanned 10 times with each intraoral scanner. The digital standard tessellation language (STL) files from each scanner were then registered to the reference file and compared with differences in trueness and precision using a 3-dimensional modeling software. Additionally, scanning time was recorded for each scan performed. The Wilcoxon signed rank, Kruskal-Wallis, and Dunn tests were used to detect differences for trueness, precision, and scanning time (α=.05). Carestream CS 3500 had the lowest overall trueness and precision compared with Bluecam and TRIOS Color. The fourth scanner, Omnicam, had intermediate trueness and precision. All of the scanners tended to underestimate the size of the reference file, with exception of the Carestream CS 3500, which was more variable. Based on visual inspection of the color rendering of signed differences, the greatest amount of error tended to be in the posterior aspects of the arch, with local errors exceeding 100 μm for all scans. The single capture scanner Carestream CS 3500 had the overall longest scan times and was significantly slower than the continuous capture scanners TRIOS Color and Omnicam. Significant differences in both trueness and precision were found among the scanners. Scan times of the continuous capture scanners were faster than the single capture scanners

  2. Embolismo graso en un niño con distrofia muscular de duchenne y fractura bilateral de fémur. una rara asociación.

    OpenAIRE

    Vergara Amador, Enrique; Galván Villamarín, Fernando; Piña Quintero, Marcela

    2011-01-01

    Las fracturas de fémur en pacientes que sufren de distrofiamuscular de Duchenne (DMD) son frecuentes, con unaincidencia entre 15-44 por ciento. El embolismo grasose presenta en fracturas de huesos largos generalmenteasociado a trauma de alta energía o a lesiones extensasde tejidos blandos. El diagnóstico de embolismo grasono es tan frecuente en niños posiblemente porque cursacon presentaciones subclínicas. No existen reportesde embolismo graso asociado a distrofia muscular deDuchenne. Informa...

  3. [Bilateral torticollis].

    Science.gov (United States)

    Kustos, T; Magdics, M

    1993-12-19

    Bilateral torticollis is a very rare form of a well known deformity i.e. muscular torticollis. This malformation might present a differential diagnostic problem both for orthopaedic surgeons and ophthalmologists, as well as, for neurologists. In agreement with the literature, the role of an injury during labour or defective embriogenesis is suggested to play a part.

  4. Bilateral agreements

    International Nuclear Information System (INIS)

    Anon.

    2004-01-01

    The bilateral agreements concern Brazil with United States relative to the co operation in nuclear energy, Germany with Russian Federation relative to the elimination and disposal of nuclear weapons; The multilateral agreements concerns the signature of the Protocols to amend the Paris and Brussels Conventions, the multilateral nuclear environmental programme in the Russian Federation, the status of Conventions in the field of nuclear energy. (N.C.)

  5. Intercomparación bilateral entre LATU y PTB de calibración en puntos fijos (ITS-90 del Zn al Hg de un SPRT con PTB como laboratorio piloto

    Directory of Open Access Journals (Sweden)

    Ofelia Robatto

    2011-05-01

    Full Text Available El Laboratorio Tecnológico del Uruguay, LATU, es el Instituto Metrológico Nacional del Uruguay, miembro fi rmante del Acuerdo de Reconocimiento Mutuo (MRA entre Laboratorios Nacionales de Metrología del Comité Internacional de Pesas y Medidas (CIPM. Las capacidades de medida y calibración (CMCs del LATU fueron reconocidas en junio de 2004 y se encuentran publicadas en la BIPM- Key Comparison Data Base (BIPM, 2009. El LATU estuvo acreditado desde 2001 hasta junio de 2007 por el Deutscher Kalibrier Dienst (Servicio de Acreditación Alemán en las magnitudes Masa, Balanzas y Temperatura (Laboratorio DKD, DKD-K-25601. Se decidió a partir de ese momento probar el cumplimiento con los criterios establecidos por el CIPM MRA y los requisitos de la Norma ISO/IEC 17025 en el marco de una auditoría in situ llevada a cabo en el LATU en enero de 2008. Como parte de ese proceso de revisión de pares, se realizó una Intercomparación Bilateral entre el PTB y el LATU en los puntos fi jos de la Escala Internacional de Temperatura (ITS-90, desde el punto triple de Hg hasta el punto de congelación del Zn, con el PTB como laboratorio piloto. En este artículo los resultados son presentados y discutidos de manera de sostener ladeclaración de mejores capacidades de medida y calibración (CMCs en sustitución de las ya declaradas.AbstractLaboratorio Tecnológico del Uruguay, LATU, is the National Metrology Institute of Uruguay, signatory of the CIPM Mutual Recognition Arrangement (CIPM MRA, has Calibration and Measurement Capabilities (CMCs in temperature that were fi rst published in the BIPM Key Comparison Data Base (BIPM, 2009 in June 2004. LATU was a DKD Laboratory accredited in Mass, Balances and Temperature from 2001 until June 2007 when it was decided to adopt the CIPM criteria for proving compliance with ISO/IEC 17025 through a Peer Review process. The LATU on site Peer Review was carried out in January 2008, as part of the process. During the

  6. Analgesia pós-operatória com bloqueio bilateral do nervo pudendo com bupivacaína S75:R25 a 0,25%: estudo piloto em hemorroidectomia sob regime ambulatorial Analgesia pos-operatoria con bloqueo bilateral del nervio pudendo con bupivacaína S75:R25 a 0,25%: estudio piloto en hemorroidectomia bajo régimen ambulatorial Bilateral pudendal nerves block for postoperative analgesia with 0.25% S75:R25 bupivacaine: pilot study on outpatient hemorrhoidectomy

    Directory of Open Access Journals (Sweden)

    Luiz Eduardo Imbelloni

    2005-12-01

    permitirão demonstrar se esta técnica deve ser a primeira opção para analgesia em hemorroidectomias. A permanência de anestesia perineal por 20,21 horas deverá induzir novos trabalhos com o bloqueio dos nervos pudendos orientado por estimulador para o ato cirúrgico.JUSTIFICATIVA Y OBJETIVOS: La hemorroidectomia puede ser realizada bajo varias técnicas anestésicas y en régimen ambulatorial. El dolor pos-operatorio es intenso y puede atrasar el retorno para el hogar. El objetivo de este estudio fue evaluar las ventajas y la realización del bloqueo bilateral de los nervios pudendos para analgesia pos-operatoria en hemorroidectomias. MÉTODO: El bloqueo bilateral de los nervios pudendos con bupivacaína S75:R25 a 0,25% fue realizado con estimulador de nervios en 35 pacientes sometidos a la hemorroidectomia bajo raquianestesia. Fueron evaluadas intensidad del dolor, duración de la analgesia, analgesia de demanda y eventuales complicaciones relacionadas a la técnica. Los datos fueron evaluados a las 6, 12, 18, 24 y 30 horas después del término de la intervención quirúrgica. RESULTADOS: En todos los pacientes, fue logrado éxito con la estimulación de ambos los nervios pudendos. En ningún momento de la evaluación ocurrió dolor intenso. Hasta 12 horas después del bloqueo, todos los pacientes presentaron anestesia en la región perineal; con 18 horas, 17 pacientes y 24 horas, 10 pacientes A analgesia pos-operatoria fue óptima en 18 pacientes; satisfactoria, en cinco pacientes; e insatisfactoria, en siete pacientes. La duración media de la analgesia fue de 23,77 horas. No ocurrieron alteraciones de la presión arterial, de la frecuencia cardiaca, ni fueron observados náuseas o vómitos. Todos los pacientes tuvieron micción espontánea. Ninguna complicación local o sistémica fue relacionada al anestésico local. Veintisiete pacientes clasificaron de excelente la técnica de analgesia y apenas tres pacientes del sexo masculino quedaron satisfechos

  7. Anestesia para salpingectomia parcial bilateral em paciente com miocardiopatia hipertrófica idiopática: relato de um caso e revisão da literatura Anestesia para salpingectomía parcial bilateral en paciente con miocardiopatía hipertrófica idiopática: relato de un caso y revisión del literatura Anesthesia for partial bilateral salpingectomy in a patient with idiopathic hypertrophic cardiomyopathy: case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Ana Sofia Del Castillo Sardi

    2010-02-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A miocardiopatia hipertrófica é uma doença cardíaca rara, com transmissão autossômica dominante e que se caracteriza pela hipertrofia do septo ventricular e pelas anormalidades da valva mitral. RELATO DO CASO: Paciente secundípara, de 25 anos, com diagnóstico de miocardiopatia hipertrófica há quatro anos e antecedente de asma leve intermitente controlada com inalações esporádicas de corticosteroides. Apresentava sopro holossistólico IV/VI plurifocal e importante escoliose, com os espaços intervertebrais palpáveis. Acusou palpitações esporádicas durante toda a gravidez e recebia medicação de 100 mg de atenolol por dia. Apresentava hemograma, creatinina e eletrólitos dentro dos limites normais, ecocardiograma com miocardiopatia hipertrófica de predomínio septal, com fração de ejeção sistólica de 0,76%. A paciente entrou em trabalho de parto de rápida evolução e nasceu criança viva, do sexo feminino, com APGAR 9/9 sem complicações maternas nem fetais. Foi realizada a programação para a realização de salpingectomia parcial bilateral. Em consulta, a paciente negou-se a receber anestesia para o procedimento. A técnica anestésica de eleição foi a regional combinada. O procedimento cirúrgico durou 20 minutos e as mudanças de pressão arterial junto com a frequência cardíaca foram 10% menores que as dos valores iniciais, sem complicações hemodinâmicas nem cirúrgicas imediatas. CONCLUSÕES: A mortalidade absoluta materna com miocardiopatia hipertrófica (MH é muito baixa e costuma aparecer em mulheres com fatores de alto risco. Não há evidências de que a anestesia regional aumente o risco em mulheres com MH quando é utilizada para o parto vaginal. Tanto a anestesia geral como a regional foram utilizadas com sucesso e sem complicações em cesarianas de parturientes com MH.JUSTIFICATIVA Y OBJETIVOS: La cardiomiopatía hipertrófica es enfermedad cardíaca rara, con transmisi

  8. Evaluation of occupational exposure in intraoral radiography; Avaliacao da dose ocupacional em radiografia intraoral

    Energy Technology Data Exchange (ETDEWEB)

    Miguel, Cristiano; Barros, Frieda S.; Rocha, Anna S.P.S.; Godoi, Walmor C., E-mail: miguel_cristianoch@yahoo.com.br, E-mail: saicla@utfpr.edu.br, E-mail: annarocha@yahoo.com, E-mail: walmor.godoi@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Tilly Junior, Joao G., E-mail: joao.tilly@derax.com.br [Universidade Federal do Parana (HC/UFPR), Curitiba, PR (Brazil). Hospital das Clinicas

    2014-07-01

    The intraoral radiography is widely performed in the dental office due to low cost and agility. The doses in intraoral radiology are considered low, however it is known that doses below the threshold for deterministic radiation has the potential to induce stochastic effects. An intraoral radiography has a risk of inducing fatal cancer or serious in order of 1:10,000,000. Besides the patient, the dentist may also be being exposed to radiation during the work with the radiographics practices. The bibliographies demonstrates the lack of information on radiation protection of dentists, however, the occupational dose reduction was observed in radiology over the past 14 years. This work aims to evaluate the effective dose of radiation to which workers can be exposed dentists in dental offices to perform intraoral radiographs. In this context, a study was be conducted between June 2013 and May 2014 with 44 professionals in Curitiba city. For each dentist was given a personal dosimeter to be used for 30 days. During this period, the number of radiographies and the length of the cable triggers of the X-ray equipment was registered and, the dosimeter´s dose was read. It was observed that the cables triggers meet regulatory standards and allow dentists to get the mean minimum distance of two meters from the radiation source in 93% of cases. Through analysis of the doses, it was concluded that occupational exposures of these workers are within the recommended threshold by regulatory 453/1998 of the Ministry of Health from Brazil. (author)

  9. Magnetic resonance imaging of intraoral hard and soft tissues using an intraoral coil and FLASH sequences

    Energy Technology Data Exchange (ETDEWEB)

    Fluegge, Tabea; Eisenbeiss, Anne-Kathrin; Schmelzeisen, Rainer; Nelson, Katja [University Medical Center Freiburg, Department of Oral and Maxillofacial Surgery, Freiburg (Germany); Hoevener, Jan-Bernd; Ludwig, Ute; Hennig, Juergen [University Medical Center Freiburg, Medical Physics, Department of Radiology, Freiburg (Germany); Spittau, Bjoern [Albert Ludwig University of Freiburg, Institute of Anatomy and Cell Biology, Freiburg (Germany)

    2016-12-15

    To ascertain the feasibility of MRI as a non-ionizing protocol for routine dentomaxillofacial diagnostic imaging. Wireless coils were used for MRI of intraoral hard and soft tissues. FLASH MRI was applied in vivo with a mandible voxel size of 250 x 250 x 500 μm{sup 3}, FOV of 64 x 64 x 28 mm{sup 3} and acquisition time of 3:57 min and with a maxilla voxel size of 350 μm{sup 3} and FOV of 34 cm{sup 3} in 6:40 min. Ex vivo imaging was performed in 4:38 min, with a resolution of 200 μm{sup 3} and FOV of 36.5 cm{sup 3}. Cone beam (CB) CT of the mandible and subjects were acquired. MRI was compared to CBCT and histological sections. Deviations were calculated with intraclass correlation coefficient (ICC) and coefficient of variation (c{sub v}). A high congruence between CBCT, MRI and specimens was demonstrated. Hard and soft tissues including dental pulp, periodontium, gingiva, cancellous bone and mandibular canal contents were adequately displayed with MRI. Imaging of select intraoral tissues was achieved using custom MRI protocols with an easily applicable intraoral coil in a clinically acceptable acquisition time. Comparison with CBCT and histological sections helped demonstrate dimensional accuracy of the MR images. The course of the mandibular canal was accurately displayed with CBCT and MRI. (orig.)

  10. Magnetic resonance imaging of intraoral hard and soft tissues using an intraoral coil and FLASH sequences

    International Nuclear Information System (INIS)

    Fluegge, Tabea; Eisenbeiss, Anne-Kathrin; Schmelzeisen, Rainer; Nelson, Katja; Hoevener, Jan-Bernd; Ludwig, Ute; Hennig, Juergen; Spittau, Bjoern

    2016-01-01

    To ascertain the feasibility of MRI as a non-ionizing protocol for routine dentomaxillofacial diagnostic imaging. Wireless coils were used for MRI of intraoral hard and soft tissues. FLASH MRI was applied in vivo with a mandible voxel size of 250 x 250 x 500 μm 3 , FOV of 64 x 64 x 28 mm 3 and acquisition time of 3:57 min and with a maxilla voxel size of 350 μm 3 and FOV of 34 cm 3 in 6:40 min. Ex vivo imaging was performed in 4:38 min, with a resolution of 200 μm 3 and FOV of 36.5 cm 3 . Cone beam (CB) CT of the mandible and subjects were acquired. MRI was compared to CBCT and histological sections. Deviations were calculated with intraclass correlation coefficient (ICC) and coefficient of variation (c v ). A high congruence between CBCT, MRI and specimens was demonstrated. Hard and soft tissues including dental pulp, periodontium, gingiva, cancellous bone and mandibular canal contents were adequately displayed with MRI. Imaging of select intraoral tissues was achieved using custom MRI protocols with an easily applicable intraoral coil in a clinically acceptable acquisition time. Comparison with CBCT and histological sections helped demonstrate dimensional accuracy of the MR images. The course of the mandibular canal was accurately displayed with CBCT and MRI. (orig.)

  11. Extraoral periapical radiography: an alternative approach to intraoral periapical radiography

    International Nuclear Information System (INIS)

    Kumar, Rahul; Khambete, Neha; Priya, Ekta

    2011-01-01

    It is difficult to take intraoral radiographs in some patients who are intolerable to place the film in their mouth. For these patients, Newman and Friedman recommended a new technique of extraoral film placement. Here we report various cases that diagnostic imaging was performed in patients using the extraoral periapical technique. This technique was used to obtain the radiographs for the patients with severe gag reflex, pediatric dental patients, and patients with restricted mouth opening. This technique can be recommended as an alternative to conventional intraoral periapical technique in cases where intraoral film placement is difficult to achieve.

  12. Guides for intraoral x-rays

    International Nuclear Information System (INIS)

    Ogunsunlade, O.A.

    1988-01-01

    An h-shaped exterior guide for use in combination with a SNAP-A-RAY film holder for accurately aligning a beam from an X-ray cone with an X-ray film during the process of taking intraoral periapical dental X-rays of the maxillary and mandibular teeth is described comprising: a first guide arm laterally and detachably connectable through a housing means; a traverse arm extending from the midpoint of the first guide arm and parallel to the X-ray film; and a second guide arm extending perpendicularly from an end of the traverse arm toward a plane of the X-ray film and in parallel relation up to an end point of the first guide arm

  13. Intraoral hydatid cyst: A rare case report

    Directory of Open Access Journals (Sweden)

    Ravi Kiran Alaparthi

    2015-01-01

    Full Text Available "Hydatid" is a Greek word which means "a drop of water." Hydatid cysts occur in hydatid disease or echinococcosis, which is one of the most geographically prevalent zoonosis. This zoonotic infection in humans is mainly caused by infection by the larval stage of the dog tapeworm Echinococcus granulosus. This tapeworm infestation is widespread in sheep, goats, cattle, and dogs. This chronic disease is present worldwide among herding populations who live in close proximity to dogs and herd animals. It is a serious and potentially fatal condition and symptoms may occur a long time after the early infection. The most frequently affected organs are liver, lungs, followed by bones and brain, and extremely unusual occurrence has been found in the oral cavity, which was noticed in the present case. So hereby, we reveal a very rare case of intraoral hydatid cyst in a 20-year-old female patient.

  14. Intraoral blue (Jadassohn-Tieche) nevus.

    Science.gov (United States)

    Hasse, C D; Zoutendam, G L; Gombas, O F

    1978-05-01

    Blue nevus of the oral mucosa is a distinctly uncommon clincial entity. Careful review of the literature yielded thirty-one previously reported cases. The present article reports the occurrence of a blue nevus of the hard palate in a 58-year-old man. It is of interest since it is the smallest (1 by 1 mm.) intraoral blue nevus to be reported. A clinicopathologic study of the previous thirty-one cases and of our case suggests that this lesion has no age or sex predilection. The most common site of occurrence was the hard palate. There appears to be no tendency toward recurrence. A brief review of the historical background, clinical features, theories of possible origin, and differential diagnosis is presented. Excisional biopsy of localized areas of oral pibmentation, together with histopathologic study, is indicated to rule out melanoma.

  15. Intraoral digital impressions to enhance implant esthetics.

    Science.gov (United States)

    Hinds, Kenneth F

    2014-09-01

    Providing an accurate soft-tissue transfer for anterior implants is not a new concept; however, it is currently an especially relevant one. There are numerous documented cases in which residual excess cement with cement-retained implant restorations was a contributing cause in periimplantitis. In 2012, Wadhwani et al reported the importance of placing the crown abutment margins supragingivally for ease of cement removal as a possible solution to address this important issue. Therefore, if placement of the crown abutment margin location is imperative, making an impression that reproduces the soft tissue is equally critical. In 1997, this author introduced the "custom impression coping" to achieve such an accurate transfer. Given the wide use of intraoral digital impressions in 2014, this discussion describes how to fabricate a "custom scan body" using that technology to replicate the transition zone in the virtual environment.

  16. Motivation and compliance with intraoral elastics.

    Science.gov (United States)

    Veeroo, Helen J; Cunningham, Susan J; Newton, Jonathon Timothy; Travess, Helen C

    2014-07-01

    Intraoral elastics are commonly used in orthodontics and require regular changing to be effective. Unfortunately, poor compliance with elastics is often encountered, especially in adolescents. Intention for an action and its implementation can be improved using "if-then" plans that spell out when, where, and how a set goal, such as elastic wear, can be put into action. Our aim was to determine the effect of if-then plans on compliance with elastics. To identify common barriers to compliance with recommendations concerning elastic wear, semistructured interviews were carried out with 14 adolescent orthodontic patients wearing intraoral elastics full time. Emerging themes were used to develop if-then plans to improve compliance with elastic wear. A prospective pilot study assessed the effectiveness of if-then planning aimed at overcoming the identified barriers on compliance with elastic wear. Twelve participants were randomized equally into study and control groups; the study group received information about if-then planning. The participants were asked to collect used elastics, and counts of these were used to assess compliance. A wide range of motivational and volitional factors were described by the interviewed participants, including the perceived benefits of elastics, cues to remember, pain, eating, social situations, sports, loss of elastics, and breakages. Compliance with elastic wear was highly variable among patients. The study group returned more used elastics, suggesting increased compliance, but the difference was not significant. The use of if-then plans might improve compliance with elastic wear when compared with routine clinical instructions. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  17. Bilateral agreements

    International Nuclear Information System (INIS)

    1998-01-01

    Ten bilateral agreements are presented. These are: 1) Co-operation agreement relating to the peaceful uses of nuclear energy between Argentina and EURATOM (1996); 2) Agreement on co-operation in the peaceful uses of nuclear energy between Argentina and Greece (1997); 3) Implementing arrangement for technical exchange and co-operation in the area of peaceful uses of nuclear energy between Argentina and the United States (1997); 4) Agreement concerning co-operation in nuclear science and technology between Australia and Indonesia (1997); 5) Implementation of the 1985 Agreement for co-operation concerning the peaceful uses of nuclear energy between the People's Republic of China and the United States (1998); 6) Protocol of co-operation between France and Lithuania (1997); 7) Agreement on co-operation in energy research, science and technology, and development between Germany and the United States (1998); 8) Agreement on early notification of a nuclear accident and exchange of information on nuclear facilities between Greece and Romania (1997); 9) Agreement on early notification of nuclear accidents and co-operation in the field of nuclear safety between Hungary and the Ukraine (1997); 10) Agreement in the field of radioactive waste management between Switzerland and the United States (1997). (K.A.)

  18. Surgical resection of a huge cemento-ossifying fibroma in skull base by intraoral approach.

    Science.gov (United States)

    Cheng, Xiao-Bing; Li, Yun-Peng; Lei, De-Lin; Li, Xiao-Dong; Tian, Lei

    2011-03-01

    Cemento-ossifying fibroma, also known as ossifying fibroma, usually occurs in the mandible and less commonly in the maxilla. The huge example in the skull base is even rare. We present a case of a huge cemento-ossifying fibroma arising below the skull base of a 30-year-old woman patient. Radiologic investigations showed a giant, lobulated, heterogeneous calcified hard tissue mass, which is well circumscribed and is a mixture of radiolucent and radiopaque, situated at the rear of the right maxilla to the middle skull base. The tumor expands into the right maxillary sinus and the orbital cavity, fusing with the right maxilla at the maxillary tuberosity and blocking the bilateral choanas, which caused marked proptosis and blurred vision. The tumor was resected successfully by intraoral approach, and pathologic examination confirmed the lesion to be a cemento-ossifying fibroma. This case demonstrates that cemento-ossifying fibroma in the maxilla, not like in the mandible, may appear more aggressive because the extensive growth is unimpeded by anatomic obstacles and that the intraoral approach can be used to excise the tumor in the skull base.

  19. Mondani intraoral welding: historical process and main practical applications.

    Science.gov (United States)

    Dal Carlo, L; Pasqualini, M E; Mondani, P M; Rossi, F; Moglioni, E; Shulman, M

    2017-01-01

    The intraoral welder was invented by Dr. Pierluigi Mondani during the early 70’s to weld titanium needle implants to a titanium bar in patient’s mouth and to load them immediately by means of resin prosthesis. The clinical use documented dates back to 1972. Over the years, many practical applications have been added to the initial one, which have expanded the use of this device. In this scientific work, main applications are described. The aim of the work was to trace the historical process of intra-oral welding according to Mondani and describe the main practical applications. Intra-oral welding is a process introduced by dr. Pier Luigi Mondani of Genova (Italy) which allows to firmly conjoin titanium implants of any shape by means of a titanium bar or also directly between them in the mouth during surgery. The immediate stabilization achieved by intraoral welding increases implants success rate, allows immediate loading even in situations of bone atrophy, saves implants that are running into failure, re-evaluates fractured implants, allows to stabilize submerged implants postponing prosthesis management, allows to achieve efficient rehabilitation protocols to deal with difficult cases. The 40-years’ experience with intra-oral welding described in this article, confirms the ease of use and efficiency in providing immediate stabilization of titanium implants of all types.

  20. Dose measurements in intraoral radiography using thermoluminescent dosimeters

    Science.gov (United States)

    Azorín, C.; Azorín, J.; Aguirre, F.; Rivera, T.

    2015-01-01

    The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations.

  1. Dose measurements in intraoral radiography using thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Azorín, C; Rivera, T; Azorín, J; Aguirre, F

    2015-01-01

    The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations

  2. Bilateral Complete and Incomplete Fusion of Incisors and its Management.

    Science.gov (United States)

    Da Costa, Godwin Clovis; Chalakkal, Paul; De Souza, Neil; Gavhane, Sanket

    2017-01-01

    This case report highlights the management of a case of bilateral complete and incomplete fusion of maxillary incisors in a 10-year-old child. A mock-up was done on the diagnostic cast. Pretreatment esthetic evaluation was done using bis-acryl composite temporaries which were transferred intraorally from the diagnostic cast using a putty index. An incisal overlap veneer preparation was done, following which, an IPS e-max veneer was cemented. A digital mock-up was carried out using the Adobe Photoshop and Corel Draw softwares to aid in laboratorial fabrication of the veneer.

  3. Bilateral complete and incomplete fusion of incisors and its management

    Directory of Open Access Journals (Sweden)

    Godwin Clovis Da Costa

    2017-01-01

    Full Text Available This case report highlights the management of a case of bilateral complete and incomplete fusion of maxillary incisors in a 10-year-old child. A mock-up was done on the diagnostic cast. Pretreatment esthetic evaluation was done using bis-acryl composite temporaries which were transferred intraorally from the diagnostic cast using a putty index. An incisal overlap veneer preparation was done, following which, an IPS e-max veneer was cemented. A digital mock-up was carried out using the Adobe Photoshop and Corel Draw softwares to aid in laboratorial fabrication of the veneer.

  4. Diagnostic reference levels in intraoral dental radiography in Korea

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Han, Won Jeong; Choi, Jin Woo; Jung, Yun Hoa; Yoon, Suk Ja; Lee, Jae Seo

    2012-01-01

    The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 mGycm2 (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 mGycm 2 (DAP). Doses at university dental hospitals were lower than those at dental clinics (p 2 (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

  5. Validation of 3D documentation of palatal soft tissue shape, color, and irregularity with intraoral scanning

    NARCIS (Netherlands)

    Deferm, Julie T.; Schreurs, Ruud; Baan, Frank; Bruggink, Robin; Merkx, Matthijs A. W.; Xi, Tong; Bergé, Stefaan J.; Maal, Thomas J. J.

    2017-01-01

    The purpose of this study was to assess the feasibility of 3D intraoral scanning for documentation of palatal soft tissue by evaluating the accuracy of shape, color, and curvature. Intraoral scans of ten participants' upper dentition and palate were acquired with the TRIOS® 3D intraoral scanner by

  6. Unusual presentation of firework injury causing intraoral burns

    Directory of Open Access Journals (Sweden)

    Patel Chintan

    2005-01-01

    Full Text Available Fireworks are commonly used in celebrate festive occasions. We present a case of an unusual presentation of intraoral firework injury, which is a very rare case. A fifteen year old boy kept four explosive papercaps wrapped in a small polythene bags in between his left molars and crushed them. This resulted in a contused lacerated wound over the left buccal mucosa. Patient was treated conservatively with maintenance of intraoral hygiene, antibiotics, proteolytic enzymes and analgesics. It took 18 days for complete healing of the wound.

  7. The repeatability of an intraoral dental colorimeter.

    Science.gov (United States)

    Tung, Francis F; Goldstein, Gary R; Jang, Sungkoo; Hittelman, Eugene

    2002-12-01

    Characterizing and reproducing color remain one of the most challenging aspects of dentistry. A relatively new intraoral colorimeter measures the color of natural teeth and metal-ceramic restorations and prints out a color recipe for the Vintage Halo Porcelain System. The reliability of the colorimeter is unknown. The purpose of this study was to evaluate the reliability of a contact dental colorimeter and to correlate the shade registered by the colorimeter with the shade selected by experienced clinicians. In part I of the study, 2 examiners (A and B) took 2 colorimeter measurements from the maxillary right central incisors of 11 subjects. The examiners were blinded to their own data and those of other investigators. The readings were repeated 3 weeks later with the same protocol. The Cronbach alpha reliability coefficient was used to analyze the collected data. In part II of the study, 2 experienced clinicians (examiners D and E) selected a shade from the classic Vita Lumin Vacuum shade guide for the maxillary right central incisors of the same 11 subjects. The clinicians were blinded to each other's selections and the colorimeter readings. It should be noted that the manufacturer of the colorimeter uses the terms shade, value, and hue to represent chroma, value, and hue, respectively, as defined in the Glossary of Prosthodontic Terms (J Prosthet Dent 1999;81:39-110). The reliability analysis results for each of the combined trials for shade, value, and hue were all >.94. The interexaminer reliability alpha values were >.9 for shade and value and.64 to.74 for hue. The interexaminer alpha represented the value range of each of 4 measurements. The intraexaminer reliability alpha values for shade, value, and hue were.99,.95, and.96 for examiner A and.99,.93, and.97 for examiner B, respectively. In part II of the study, the colorimeter agreed with itself 82% of the time, whereas clinicians agreed with each other on the selected shade 73% of the time. Selections made

  8. [Imaging analysis of temporomandibular joint anatomy changes after intraoral condylectomy combined with orthognathic surgery].

    Science.gov (United States)

    Luo, N J; Li, Z L; Yi, B; Liang, C; Wang, X; Wang, X X

    2016-06-01

    To quantitatively analyze the changes of facial symmetry and temporomandibular joint structure at different periods after intraoral condylectomy combined with orthognathic surgery, and to evaluate the long-term stability after the operation. Spiral CT data of 10 cases treated by intraoral condylectomy combined with orthognathic surgery were collected, and then reconstructed by ProPlan software. Mark points were drawn on the 3D-images reconstructed immediately after the operation, and 6 months and 12 months after the operation. The measurements parameters included condylar axis angle in three dimensions, condylar-glenoid relative position and condylar facial morphology related indicators. The results were statistically analyzed by the consistency test and the variance of repeated measurement data. The facial asymmetry of the patients was corrected after operation, the height of the affected mandibular ascending ramus(T1: [67.81±6.95]mm, T2: [64.49±6.24]mm, T3: [63.05±7.07]mm)as well as the degree of pogonion deviation decreased(T1: [2.79±4.93]mm, T2: [0.37±4.20]mm, T3: [0.33 ± 3.97]mm)(P0.05). The post-operative 3D changes of the position and shape of the resected and its contralateral condylar showed that the bilateral condylar axis angle in the horizontal plane gradually grew after operation(affected condyle: 71.95° ± 7.47°, 74.73°±8.44°, 76.56°±5.22°; control condyle: 72.60°±5.56°, 76.00°±5.30°, 77.19°±6.20° and had significant difference between all the post-operative periods)(P0.05). The intraoral condylectomy combined with orthognathic surgery can eliminate condylar lesions effectively and correct the facial asymmetry caused by condylar benign tumor and hyperplasia. The facial symmetry can be maintained well after the operation, and the post-operative condylar morphology changes tended to be stable six months after the operation.

  9. Intraoral approach: A newer technique for filler injection

    Directory of Open Access Journals (Sweden)

    Chytra V Anand

    2010-01-01

    Full Text Available Filler injections are the most common aesthetic procedures used for volume correction. Various techniques have been described in the use of fillers. This article reviews the available literature on a new technique using the intraoral approach for injection of fillers.

  10. Digital Intraoral Imaging Re-Exposure Rates of Dental Students.

    Science.gov (United States)

    Senior, Anthea; Winand, Curtis; Ganatra, Seema; Lai, Hollis; Alsulfyani, Noura; Pachêco-Pereira, Camila

    2018-01-01

    A guiding principle of radiation safety is ensuring that radiation dosage is as low as possible while yielding the necessary diagnostic information. Intraoral images taken with conventional dental film have a higher re-exposure rate when taken by dental students compared to experienced staff. The aim of this study was to examine the prevalence of and reasons for re-exposure of digital intraoral images taken by third- and fourth-year dental students in a dental school clinic. At one dental school in Canada, the total number of intraoral images taken by third- and fourth-year dental students, re-exposures, and error descriptions were extracted from patient clinical records for an eight-month period (September 2015 to April 2016). The data were categorized to distinguish between digital images taken with solid-state sensors or photostimulable phosphor plates (PSP). The results showed that 9,397 intraoral images were made, and 1,064 required re-exposure. The most common error requiring re-exposure for bitewing images was an error in placement of the receptor too far mesially or distally (29% for sensors and 18% for PSP). The most common error requiring re-exposure for periapical images was inadequate capture of the periapical area (37% for sensors and 6% for PSP). A retake rate of 11% was calculated, and the common technique errors causing image deficiencies were identified. Educational intervention can now be specifically designed to reduce the retake rate and radiation dose for future patients.

  11. Assessment of intraoral image artifacts related to photostimulable ...

    African Journals Online (AJOL)

    2015-04-21

    Apr 21, 2015 ... Materials and Methods: A total of 11,443 intraoral images, including 4291 periapical and 7152 bitewing ... that produce a latent image when exposed to radiation. ..... dropped on the floor or if a patient bites hard into their.

  12. Diurnal variation of intraoral pH and temperature.

    Science.gov (United States)

    Choi, Jung Eun; Lyons, Karl M; Kieser, Jules A; Waddell, Neil J

    2017-01-01

    The aim of this study was to measure continuously the intraoral pH and temperature of healthy individuals to investigate their diurnal variations. Seventeen participants (mean age, 31±9 years) wore a custom-made intraoral appliance fitted with a pH probe and thermocouple for two sets of 24 h, while carrying out normal daily activities including sleep. The continuous changes in intraoral pH and temperature were captured using a sensor placed on the palatal aspect of the upper central incisors. The collected data were categorised into different status (awake and sleep) and periods (morning, afternoon, evening and night). Both quantitative and qualitative analyses were conducted. The intraoral pH change was found to show a distinctive daily rhythm, showing a 12-h interval between maximum (7.73) and minimum (6.6) pH values. The maximum and minimum values were found to repeat after 24 h. The mean pH over 48 h (two sets of 24 h) was found to be 7.27 (±0.74). There was significant difference found in pH when subjects were awake and asleep and different periods during the day ( P pH. There was a significant difference found in temperature depending on the time of the day, except between morning and afternoon ( P =0.78). Our results showed that there is a distinctive daily, circadian-like pattern in intraoral pH variation over a 24-h period, which has been considered as one of the risk factors in sleep-related dental diseases.

  13. Intra-oral Sebaceous Gland Tumours in Two Dogs.

    Science.gov (United States)

    Go, D-M; Lee, S-H; Woo, S-H; Kim, D-Y

    2017-11-01

    A 12-year-old female miniature schnauzer and a 12-year-old neutered female cocker spaniel each had a grey-yellow nodular lesion arising from the gingiva. Microscopical examination showed that both nodules were composed of varied proportions of sebocytes and basal-type reserve cells with few ducts lined by stratified squamous epithelium. Based on the histopathological findings, the cases were diagnosed as sebaceous adenoma and sebaceous epithelioma, respectively. In man, the occurrence of sebaceous neoplasms in the oral cavity has been reported to some extent, but these lesions are very rare in animals. To the best of our knowledge, this is the first report of intra-oral sebaceous neoplasms in dogs. Intra-oral sebaceous epithelioma has never been reported in animals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Factors affecting intra-oral pH - a review.

    Science.gov (United States)

    Loke, C; Lee, J; Sander, S; Mei, L; Farella, M

    2016-10-01

    One of the greatest challenges to modern dentistry is the progressive destruction of tooth material due to chemical erosion. Dental erosion is the loss of dental hard tissue, without the action of bacteria, in which demineralisation of enamel and dentine results due to a decrease in intra-oral pH. The aim of this review was to appraise the scientific literature on the factors that can affect intra-oral pH. The review will examine (i) the protective role of human saliva, in terms of its mineral composition, flow rates and buffering systems and (ii) sources of in-mouth acids such as extrinsic acids, which are derived from the diet and environment, as well as intrinsic acids, which are related to disorders of the gastro-oesophageal tract. This review may assist clinicians to identify the risk factors for tooth wear and to recommend adequate preventive measures to patients. © 2016 John Wiley & Sons Ltd.

  15. Piezosurgical osteotomy for harvesting intraoral block bone graft

    Science.gov (United States)

    Lakshmiganthan, Mahalingam; Gokulanathan, Subramanium; Shanmugasundaram, Natarajan; Daniel, Rajkumar; Ramesh, Sadashiva B.

    2012-01-01

    The use of ultrasonic vibrations for the cutting of bone was first introduced two decades ago. Piezoelectric surgery is a minimally invasive technique that lessens the risk of damage to surrounding soft tissues and important structures such as nerves, vessels, and mucosa. It also reduces damage to osteocytes and permits good survival of bony cells during harvesting of bone. Grafting with intraoral bone blocks is a good way to reconstruct severe horizontal and vertical bone resorption in future implants sites. The piezosurgery system creates an effective osteotomy with minimal or no trauma to soft tissue in contrast to conventional surgical burs or saws and minimizes a patient's psychological stress and fear during osteotomy under local anesthesia. The purpose of this article is to describe the harvesting of intraoral bone blocks using the piezoelectric surgery device. PMID:23066242

  16. Piezosurgical osteotomy for harvesting intraoral block bone graft

    Directory of Open Access Journals (Sweden)

    Mahalingam Lakshmiganthan

    2012-01-01

    Full Text Available The use of ultrasonic vibrations for the cutting of bone was first introduced two decades ago. Piezoelectric surgery is a minimally invasive technique that lessens the risk of damage to surrounding soft tissues and important structures such as nerves, vessels, and mucosa. It also reduces damage to osteocytes and permits good survival of bony cells during harvesting of bone. Grafting with intraoral bone blocks is a good way to reconstruct severe horizontal and vertical bone resorption in future implants sites. The piezosurgery system creates an effective osteotomy with minimal or no trauma to soft tissue in contrast to conventional surgical burs or saws and minimizes a patient′s psychological stress and fear during osteotomy under local anesthesia. The purpose of this article is to describe the harvesting of intraoral bone blocks using the piezoelectric surgery device.

  17. Radiation exposure and dose evaluation in intraoral dental radiology

    International Nuclear Information System (INIS)

    Poppe, B.; Looe, H. K.; Pfaffenberger, A.; Eenboom, F.; Chofor, N.; Sering, M.; Ruehmann, A.; Poplawski, A.; Willborn, K.

    2007-01-01

    In this study, dose area product measurements have been performed to propose diagnostic reference levels (DRLs) in intraoral dental radiology. Measurements were carried out at 60 X-ray units for all types of intraoral examinations performed in clinical routine. The third quartile values calculated range from 26.2 to 87.0 mGy cm 2 . The results showed that there exists a large difference between the patient exposures among different dental facilities. It was also observed that dentists working with faster film type or higher tube voltage are not always associated with lower exposure. The study demonstrated the necessity to have the DRLs laid out as guidelines in dental radiology. (authors)

  18. Multiple intraoral neurofibromas: Case report and review of the literature

    Directory of Open Access Journals (Sweden)

    C Krithika

    2009-01-01

    Full Text Available Neurofibromatosis type I (NF I is an autosomal dominant disease transmitted with a high degree of penetrance. The disease is expressed in different forms. NF I accounts for almost 90% of the cases although nine types have been described to date. We report one such case of a 40-year-old male who presented with multiple nodules on the body and multiple intraoral soft tissue swellings. He was diagnosed to have NF I, having satisfied the diagnostic criteria for the same. This paper highlights the clinical features and diagnostic criteria of NF, the prevalence and the significance of intraoral neurofibromas and the need for the general practitioner to be aware of this condition.

  19. Full-Mouth Intraoral Radiographic Survey in Rabbits.

    Science.gov (United States)

    Regalado, Adriana; Legendre, Loïc

    2017-09-01

    Dental pathologies are highly prevalent in pet rabbit populations, making oral radiography an essential tool in the evaluation of lagomorph dentitions. The unique anatomy of the rabbit's mouth limits the examination of the conscious animal to the rostral portion of it's mouth. In addition, the oral examination of an aradicular hypsodont tooth is restricted to the short coronal fraction of its crown. Erstwhile images obtained by the extraoral technique were once considered the most practical and informative tool in rabbit dentistry; however, limited visualization of the key structures of individual teeth became the major drawback of this technique. As new imaging technologies are becoming widely available and affordable for veterinarians, intraoral radiography offers the ability to prevent, diagnose, and treat oral pathologies in lagomorphs. This article describes a step-by-step procedure to obtain a full-mouth radiographic survey in rabbits. For this technique, a standard dental X-ray generator and intraoral storage phosphor plates are used while applying the bisecting angle technique. Among the advantages of this technique are detailed visualization of internal and external dental structures, identification of early lesions, and detection of occult pathologies. Furthermore, intraoral images offer superior resolution and higher diagnostic quality with minimal radiation exposure, making this method safer for the veterinarian, staff members, and their patients.

  20. Intraoral Laser Welding (ILW in Implant Prosthetic Dentistry: Case Report

    Directory of Open Access Journals (Sweden)

    Carlo Fornaini

    2012-01-01

    Full Text Available The aim of this clinical study was to describe the possibility of using the Nd:YAG laser device utilized in the dental offices to weld metals intraorally. The authors, before applying this technique “in vivo” on human subjects, tested the “in vitro” metal welding efficacy of dental Nd:YAG device firstly by interferometry, SEM, and EDS and subsequently by thermal camera and thermocouples in order to record temperature changes during the welding process on bovine jaws. Four implants were inserted in the edentulous maxillary arch of a 67 years old male patient. Immediately after that, a bar previously made by the dental technician was intraorally welded to the abutments by Nd:YAG laser (Fidelis Plus III, Fotona, Slovenia with these parameters: 9.90 mJ, 1 Hz, 15 msec, 0.6 mm spot. Then the prosthesis was connected to the bar with four OT Caps. This clinical study, even if preliminary, suggests that laser welding technique may be intraorally used without side effects.

  1. Evaluation of radiation protection conditions in intraoral radiology

    Energy Technology Data Exchange (ETDEWEB)

    Miguel, Cristiano; Barros, Frieda Saicla; Rocha, Anna Silvia Penteado Setti da, E-mail: miguel_cristianoch@yahoo.com.br [Universidade Tecnologica Federal do Parana (PPGEB/UTFPR), Curitiba, PR (Brazil). Programa de Pos-graduacao em Engenharia Biomedica; Tilly Junior, Joao Gilberto [Universidade Federal do Parana (UNIR/UFPR), Curitiba, PR (Brazil). Hospital de Clinicas. Unidade de Imagem e Radioterapia; Almeida, Claudio Domingues de [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Dept. de Fisica Medica

    2016-04-15

    Introduction: The dental radiology represents about 20% of human exposure to radiation in radio diagnostic. Although the doses practiced in intraoral dentistry are considered low, they should not be ignored due to the volume of the performed procedures. This study presents the radiation protection conditions for intraoral radiology in Curitiba - PR. Methods: Data was collected through a quantitative field research of a descriptive nature during the period between September of 2013 and December of 2014. The survey sample consisted of 97 dentists and 130 intraoral equipment. The data related to the equipment was collected using structured questions and quality control evaluations. The evaluations of the entrance skin dose, the size of the radiation field and the total filtration were performed with dosimetry kits provided and evaluated by IRD/CNEN. The exposure time and voltage were measured using noninvasive detectors. The occupational dose was verified by thermoluminescent dosimeters. The existence of personal protection equipment, the type of image processing and knowledge of dentists about radiation protection were verified through the application of a questionnaire. Results: Among the survey's results, it is important to emphasize that 90% of the evaluated equipment do not meet all the requirements of the Brazilian radiation protection standards. Conclusion: The lack of knowledge about radiation protection, the poor operating conditions of the equipment, and the image processing through visual method are mainly responsible for the unnecessary exposure of patients to ionizing radiation. (author)

  2. Bilateral herpes zoster

    Directory of Open Access Journals (Sweden)

    Singh K

    1993-01-01

    Full Text Available A case of bilateral herpes zoster of lumbosacral region is reported in association with diabetes mellitus in a 55 years old female. The case is of interest due to bilateral distribution which is rare and sacral region involvement which is quite uncommon.

  3. Bilateral herpes zoster

    OpenAIRE

    Singh K; Bajaj A; Dwivedi N; Merchery A

    1993-01-01

    A case of bilateral herpes zoster of lumbosacral region is reported in association with diabetes mellitus in a 55 years old female. The case is of interest due to bilateral distribution which is rare and sacral region involvement which is quite uncommon.

  4. [Bilateral cochlear implants].

    Science.gov (United States)

    Müller, J

    2017-07-01

    Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.

  5. Pregnancy following bilateral salpingectomy

    DEFF Research Database (Denmark)

    Oturai, Annette Bang

    2008-01-01

    This report presents a rare case of spontaneous pregnancy following bilateral salpingectomy. A woman with a history of bilateral salpingectomy was admitted to hospital because of abdominal pain and positive urine HCG. Surprisingly, ultrasound confirmed a live intrauterine fetus. The pregnancy...... was unwanted, and the woman decided to terminate the pregnancy. She was offered diagnostic examination to localise a potential fistula, but she declined. In a MEDLINE search of English literature this is only the second case of spontaneous pregnancy following bilateral salpingectomy Udgivelsesdato: 2008/4/21...

  6. Osteosíntesis intraoral asistida por endoscopia en las fracturas del proceso condilar de la mandíbula: revisión de 53 casos Endoscopically assisted intraoral osteosynthesis in mandibular condylar process fractures: a review of 53 cases

    Directory of Open Access Journals (Sweden)

    Carlos Cristobal Goizueta-Adame

    2012-12-01

    Full Text Available Objetivos: La reducción anatómica con fijación rígida de la fractura extracapsular del cóndilo de la mandíbula es esencial para asegurar la correcta función articular. El abordaje intraoral ha demostrado ser una vía segura y de escasa morbilidad. Los autores revisan una serie de 53 pacientes con fracturas extracapsulares de cóndilo mandibular tratados mediante reducción abierta y fijación interna rígida a través de un acceso exclusivamente intraoral asistido por endoscopia. Material y métodos: El objetivo de la cirugía fue la reducción anatómica y la fijación interna mediante osteosíntesis rígida a través de una incisión intraoral. Se realizó una revisión de los casos intervenidos entre 2007 y 2011. Resultados: Treinta y cinco fracturas subcondíleas y 20 fracturas de cuello de cóndilo fueron intervenidas por este método. Un 55% de las fracturas presentaron una o más fracturas asociadas. A partir del control postoperatorio con ortopantomografía, se constató la corrección o mejoría del alineamiento de los fragmentos en 51 fracturas (92%. En 37 pacientes (69,8% se evitó la fijación intermaxilar. En estos pacientes se recuperó la apertura oral a las 5 semanas y media de la cirugía. En el resto, el plazo fue de casi 9 semanas de media tras la retirada del bloqueo. Cinco pacientes presentaron alteraciones oclusales, mientras que una paciente presentó limitación de apertura oral. Conclusiones: La reducción abierta con fijación interna rígida de las fracturas extracapsulares de cóndilo mandibular mediante abordaje intraoral asistido por endoscopia es un tratamiento eficaz, seguro y reproducible.Objectives: The anatomic reduction with rigid fixation of an extracapsular mandibular condyle fracture is essential to ensure that the joint functions correctly. The intraoral approach has been shown to be safe and with a low morbidity. The authors review a series of 53 patients with extracapsular mandibular condyle

  7. Versatility of radial forearm free flap for intraoral reconstruction

    Directory of Open Access Journals (Sweden)

    Jeremić Jelena V.

    2015-01-01

    Full Text Available Introduction. The radial forearm free flap has an important role in reconstruction of the oncologic defects in the region of head and neck. Objective. The aim was to present and evaluate clinical experience and results in the radial forearm free transfer for intraoral reconstructions after resections due to malignancies. Methods. This article illustrates the versatility and reliability of forearm single donor site in 21 patients with a variety of intraoral oncologic defects who underwent immediate (19 patients, 90.5% or delayed (2 patients, 9.5% reconstruction using free flaps from the radial forearm. Fascio-cutaneous flaps were used in patients with floor of the mouth (6 cases, buccal mucosa (5 cases, lip (1 case and a retromolar triangle (2 cases defects, or after hemiglossectomy (7 cases. In addition, the palmaris longus tendon was included with the flap in 2 patients that required oral sphincter reconstruction. Results. An overall success rate was 90.5%. Flap failures were detected in two (9.5% patients, in one patient due to late ischemic necrosis, which appeared one week after the surgery, and in another patient due to venous congestion, which could not be salvaged after immediate re-exploration. Two patients required re-exploration due to vein thrombosis. The donor site healed uneventfully in all patients, except one, who had partial loss of skin graft. Conclusion. The radial forearm free flap is, due to multiple advantages, an acceptable method for reconstructions after resection of intraoral malignancies. [Projekat Ministarstva nauke Republike Srbije, br. 41006

  8. Intraoral scan bodies in implant dentistry: A systematic review.

    Science.gov (United States)

    Mizumoto, Ryan M; Yilmaz, Burak

    2018-04-05

    Intraoral scan body (ISB) design is highly variable and its role in the digital workflow and accuracy of digital impressions is not well understood. The purpose of this systematic review was to determine the relevant reports pertaining to ISBs with regard to design and accuracy and to describe their evolution and role in the digital dentistry workflow. Special attention was placed on their key features in relation to intraoral scanning technology and the digitization process. A MEDLINE/PubMed search was performed to identify relevant reports pertaining to ISB usage in dentistry. This search included but was not limited to scan body features and design, scan body accuracy, and scan body techniques and the role of ISBs in computer-aided design and computer-aided manufacturing (CAD-CAM) processes. Commercially available scan bodies were examined, and a patient situation was shown highlighting the use of ISBs in the digital workflow. Deficiencies in the reports were found regarding various scan body topics, including ISB features/design, accuracy, and the role of ISBs in CAD-CAM processes. ISBs are complex implant-positioning-transfer devices that play an essential role in the digital workflow and fabrication of accurately fitting implant-supported restorations. With scanner technology rapidly evolving and becoming more widespread, future studies are needed and should be directed toward all parts of the digital workflow when using ISBs. By understanding the basic components of ISBs and how they relate to digital scanning and CAD-CAM technology, more emphasis may be placed on their importance and usage in the digital workflow to ensure accurate transfer of implant position to the virtual and analog definitive cast. Efforts should be made by clinicians to identify an optimal ISB design in relation to the specific intraoral scanning technology being used. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights

  9. Pyogenic Granuloma in a Patient of Sturge-Weber Syndrome with Bilateral Port Wine Stain- A Rare Case Report

    Directory of Open Access Journals (Sweden)

    Shantala Arunkumar

    2014-07-01

    Full Text Available Sturge-Weber syndrome (SWS also known as encephalotrigeminal angiomatosis. It is a neurocutaneous syndrome, characterized by a facial vascular birthmark and neurological abnormalities. An ipsilateral or bilateral facial cutaneous vascular malformation Port Wine Stain (PWS usually affects the upper face. Other clinical manifestations are seizures, glaucoma, hemiparesis, mental retardation and delayed developmental milestones. The main objective of this case report is to unravel such a rarest syndrome with bilateral port-wine stain, which has intraoral manifestation of pyogenic granuloma involving gingiva in an 11 year old boy.

  10. Maxillary advancement using distraction osteogenesis with intraoral device.

    Science.gov (United States)

    Takigawa, Yoko; Uematsu, Setsuko; Takada, Kenji

    2010-11-01

    This article describes the surgical orthodontic treatment of maxillary hypoplasia in a patient with cleft lip and palate using maxillary distraction osteogenesis with internal maxillary distractors. Maxillary advancement was performed to correct the retrusive maxillary facial profile and Class III malocclusion. Rotational movement of the distraction segment was made to correct the upper dental midline. Although maxillary advancement was insufficient because of unexpected breakage of the intraoral distractor after completion of the distraction, skeletal traction with a face mask compensated for the shortage. Successful esthetic improvement and posttreatment occlusal stability were achieved with no discernible relapse after 2 years of retention.

  11. Intraoral Morgellons disease or delusional parasitosis: a first case report.

    Science.gov (United States)

    Dovigi, Allan J

    2010-08-01

    Morgellons disease is a new emerging disease that is still controversial and believed to be, by some practitioners, as nothing more than delusional parasitosis. The Center for Disease Control has recently launched an epidemiological investigation into this disease due to the increased number of reports. A first case is reported of an oral lesion and symptoms consistent with Morgellons disease. The nature of the characteristic fibers associated with the intraoral lesion is investigated. Research has started at a number of institutions to elucidate the nature of this emerging disease.

  12. New intraoral x-ray fluorographic imaging for dentistry

    International Nuclear Information System (INIS)

    Higashi, T.; Osada, T.; Aoyama, W.; Iguchi, M.; Suzuki, S.; Kanno, M.; Moriya, K.; Yoshimura, M.; Tusuda, M.

    1983-01-01

    A new dental x-ray fluorographic unit has been developed. This unit is composed of small intraoral x-ray tube, a compact x-ray image intensifier, and a high-resolution TV system. The purposes for developing this equipment were to (1) directly observe the tooth during endodontic procedures and (2) reduce x-ray exposure to the patient and the dentist. The radiation exposure can be reduced to about 1/600 the exposure used with conventional dental film. In clinical trials, a satisfactory fluorographic dental image for endodontic treatment was obtained with this new device

  13. Efficiency of the cervical lead shield during intraoral radiography

    International Nuclear Information System (INIS)

    Kaffe, I.; Littner, M.M.; Shlezinger, T.; Segal, P.

    1986-01-01

    The cervical lead shield was compared with the conventional lead apron with regard to efficiency of protection against radiation during a full-month survey (fourteen periapical and two bitewing radiographs). The study was performed on a Temex tissue-equivalent human phantom, and thermoluminescent dosimetry was used to measure radiation absorption in the ovaries, testes, and thyroid gland areas. Results showed that the cervical shield significantly reduces the amount of radiation to the skin in all three areas and is equally as effective as the combination of lead apron and thyroid shield. It is therefore recommended as a protective measure during intraoral radiography

  14. Application of intra-oral dental scanners in the digital workflow of implantology

    NARCIS (Netherlands)

    van der Meer, Wicher J; Andriessen, Frank S; Wismeijer, Daniel; Ren, Yijin

    2012-01-01

    UNLABELLED: Intra-oral scanners will play a central role in digital dentistry in the near future. In this study the accuracy of three intra-oral scanners was compared. MATERIALS AND METHODS: A master model made of stone was fitted with three high precision manufactured PEEK cylinders and scanned

  15. 21 CFR 872.1810 - Intraoral source x-ray system.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1810 Intraoral source x-ray system. (a... structures. The x-ray source (a tube) is located inside the mouth. This generic type of device may include... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraoral source x-ray system. 872.1810 Section...

  16. Application of intra-oral dental scanners in the digital workflow of implantology

    NARCIS (Netherlands)

    van der Meer, W.J.; Andriessen, F.S.; Wismeijer, D.; Ren, Y.

    2012-01-01

    Intra-oral scanners will play a central role in digital dentistry in the near future. In this study the accuracy of three intra-oral scanners was compared. Materials and methods: A master model made of stone was fitted with three high precision manufactured PEEK cylinders and scanned with three

  17. A method of multi-view intraoral 3D measurement

    Science.gov (United States)

    Zhao, Huijie; Wang, Zhen; Jiang, Hongzhi; Xu, Yang; Lv, Peijun; Sun, Yunchun

    2015-02-01

    In dental restoration, its important to achieve a high-accuracy digital impression. Most of the existing intraoral measurement systems can only measure the tooth from a single view. Therfore - if we are wilng to acquire the whole data of a tooth, the scans of the tooth from multi-direction ad the data stitching based on the features of the surface are needed, which increases the measurement duration and influence the measurement accuracy. In this paper, we introduce a fringe-projection based on multi-view intraoral measurement system. It can acquire 3D data of the occlusal surface, the buccal surface and the lingual surface of a tooth synchronously, by using a senor with three mirrors, which aim at the three surfaces respectively and thus expand the measuring area. The constant relationship of the three mirrors is calibrated before measurement and can help stitch the data clouds acquired through different mirrors accurately. Therefore the system can obtain the 3D data of a tooth without the need to measure it from different directions for many times. Experiments proved the availability and reliability of this miniaturized measurement system.

  18. Facial exposure dose assessment during intraoral radiography by radiological technologists

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Hwan; Yang, Han Joon [Dept. of International Radiological Science, Hallym University of Graduate Studies, Chuncheon (Korea, Republic of)

    2014-09-15

    The study examined the changes in the decreased facial exposure dose for radiological technologists depending on increased distance between the workers and the X-ray tube head during intraoral radiography. First, the facial phantom similar to the human tissues was manufactured. The shooting examination was configured to the maxillary molars for adults (60 kVp, 10 mA, 50 msec) and for children (60 kVp, 10 mA, 20 msec), and the chamber was fixed where the facial part of the radiation worker would be placed using the intraoral radiography equipment. The distances between the X-ray tube head and the phantom were set to 10 cm, 15 cm, 20 cm, 25 cm, 30 cm, 35 cm, and 40 cm. The phantom was radiated 20 times with each examination condition and the average scattered doses were examined. The rate at the distance of 40 cm decreased by about 92.6% to 7.43% based on the scattered rays radiated at the distance of 10 cm under the adult conditions. The rate at the distance of 40 cm decreased by about 97.6% to 2.58% based on the scattered rays radiated at the distance of 10 cm under the children conditions. Protection from the radiation exposure was required during the dental radiographic examination.

  19. Radiation exposure to children in intraoral dental radiology

    International Nuclear Information System (INIS)

    Looe, H. K.; Pfaffenberger, A.; Chofor, N.; Eenboom, F.; Sering, M.; Ruehmann, A.; Poplawski, A.; Willborn, K.; Poppe, B.

    2006-01-01

    In this study, dose area product (DAP) measurements have been performed aiming at establishing diagnostic reference levels (DRLs) in paediatric intraoral dental radiology. Measurements were carried out at 52 X-ray units for all types of intraoral examinations performed in clinical routine. Not all X-ray units have pre-set child exposure settings with reduced exposure time or in some cases lower tube voltage. Child examinations are carried out using adult exposure settings at these units, which increases the DAP third quartile values by up to 50%. For example, third quartile values for peri-apical examination ranges from 14.4 to 40.9 mGy cm 2 for child settings and 20.6 to 48.8 mGy cm 2 when the adult settings are included. The results show that there exists a large difference between the patient exposures among different dental facilities. It was also observed that clinics working with faster film type or higher tube voltage are not always associated with lower exposure. (authors)

  20. Staged bilateral carotid endarterectomy

    DEFF Research Database (Denmark)

    Schroeder, T; Sillesen, H; Engell, Hans Christian

    1986-01-01

    In a series of 56 staged bilateral carotid endarterectomies, new neurologic symptoms developed in 5% and 20% following the first and second procedure, respectively. All complications were transient or minor. The incidence of postendarterectomy hypertension was significantly higher following...... the second procedure, when operations were staged less than 3 weeks apart. A correlation between these hypertensive episodes and the occurrence of new neurologic symptoms could not be shown. However, as this correlation has been proved in several other reports, bilateral carotid endarterectomy is advised...... to be staged at least 3 weeks apart. In addition, a conservative attitude towards contralateral asymptomatic lesions is proposed....

  1. Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: A novel in vivo analysis method.

    Science.gov (United States)

    Nedelcu, R; Olsson, P; Nyström, I; Rydén, J; Thor, A

    2018-02-01

    To evaluate a novel methodology using industrial scanners as a reference, and assess in vivo accuracy of 3 intraoral scanners (IOS) and conventional impressions. Further, to evaluate IOS precision in vivo. Four reference-bodies were bonded to the buccal surfaces of upper premolars and incisors in five subjects. After three reference-scans, ATOS Core 80 (ATOS), subjects were scanned three times with three IOS systems: 3M True Definition (3M), CEREC Omnicam (OMNI) and Trios 3 (TRIOS). One conventional impression (IMPR) was taken, 3M Impregum Penta Soft, and poured models were digitized with laboratory scanner 3shape D1000 (D1000). Best-fit alignment of reference-bodies and 3D Compare Analysis was performed. Precision of ATOS and D1000 was assessed for quantitative evaluation and comparison. Accuracy of IOS and IMPR were analyzed using ATOS as reference. Precision of IOS was evaluated through intra-system comparison. Precision of ATOS reference scanner (mean 0.6 μm) and D1000 (mean 0.5 μm) was high. Pairwise multiple comparisons of reference-bodies located in different tooth positions displayed a statistically significant difference of accuracy between two scanner-groups: 3M and TRIOS, over OMNI (p value range 0.0001 to 0.0006). IMPR did not show any statistically significant difference to IOS. However, deviations of IOS and IMPR were within a similar magnitude. No statistical difference was found for IOS precision. The methodology can be used for assessing accuracy of IOS and IMPR in vivo in up to five units bilaterally from midline. 3M and TRIOS had a higher accuracy than OMNI. IMPR overlapped both groups. Intraoral scanners can be used as a replacement for conventional impressions when restoring up to ten units without extended edentulous spans. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Comparison of two intraoral scanners based on three-dimensional surface analysis

    Directory of Open Access Journals (Sweden)

    Kyung-Min Lee

    2018-02-01

    Full Text Available Abstract Background This in vivo study evaluated the difference of two well-known intraoral scanners used in dentistry, namely iTero (Align Technology and TRIOS (3Shape. Methods Thirty-two participants underwent intraoral scans with TRIOS and iTero scanners, as well as conventional alginate impressions. The scans obtained with the two intraoral scanners were compared with each other and were also compared with the corresponding model scans by means of three-dimensional surface analysis. The average differences between the two intraoral scans on the surfaces were evaluated by color-mapping. The average differences in the three-dimensional direction between each intraoral scans and its corresponding model scan were calculated at all points on the surfaces. Results The average differences between the two intraoral scanners were 0.057 mm at the maxilla and 0.069 mm at the mandible. Color histograms showed that local deviations between the two scanners occurred in the posterior area. As for difference in the three-dimensional direction, there was no statistically significant difference between two scanners. Conclusions Although there were some deviations in visible inspection, there was no statistical significance between the two intraoral scanners.

  3. Bilateral meandering pulmonary veins

    Energy Technology Data Exchange (ETDEWEB)

    Thupili, Chakradhar R.; Udayasankar, Unni [Pediatric Imaging, Imaging Institute Cleveland Clinic, Cleveland, OH (United States); Renapurkar, Rahul [Imaging Institute Cleveland Clinic, Thoracic Imaging, L10, Cleveland, OH (United States)

    2015-06-15

    Meandering pulmonary veins is a rare clinical entity that can be mistaken for more complex congenital syndromes such as hypogenetic lung syndrome. We report imaging findings in a rare incidentally detected case of bilateral meandering pulmonary veins. We briefly discuss the role of imaging in diagnosing this condition, with particular emphasis on contrast-enhanced CT. (orig.)

  4. Bilateral Periventricular Nodular Heterotopia

    OpenAIRE

    J Gordon Millichap

    1998-01-01

    Two unrelated boys, ages 8 and 5 years, with a syndrome of bilateral periventricular nodular heterotopia (BPNH), regional cortical dysplasia, mild mental retardation, and frontonasal malformation (FNM) are reported from the Instituto di Neuropsychiatria Infantile, University of Pisa, Italy, and the Institute of Human Genetics, University of Minnesota Medical School, Minneapolis, MN.

  5. Homogeneous bilateral block shifts

    Indian Academy of Sciences (India)

    Douglas class were classified in [3]; they are unilateral block shifts of arbitrary block size (i.e. dim H(n) can be anything). However, no examples of irreducible homogeneous bilateral block shifts of block size larger than 1 were known until now.

  6. Synchronous, bilateral tonsillar carcinomas

    DEFF Research Database (Denmark)

    Nami Saber, Camelia; Grønhøj, Christian; Jensen, David Hebbelstrup

    2017-01-01

    INTRODUCTION: The incidence of oropharyngeal squamous cell carcinoma (OPSCC) is increasing, but data on the incidence of synchronous, bilateral tonsillar squamous cell carcinomas (BiTSCCs) is sparse. In this study, we report the incidence and tumour characteristics of BiTSCCs in a population-base...

  7. Bilateral breast carcinoma

    International Nuclear Information System (INIS)

    Kim, Eung Jo; Oh, Ki Keun

    1990-01-01

    We evaluate 311 breast cancer patients admitted to Yong Dong Severance Hospital Between October 1st 1985 and July 31th 1989, and were able to obtain the following conclusions. 1) There were 14(4.5%) bilateral breast cancers among the 311 confirmed breast cancers. 2) Among the bilateral breast cancers, 5(31%) were synchronous and 9(69%) metachronous. 3) Average interval between the first and the second breast cancer in metachronous cancers was 3.8 year(1-15 years). 4) Bilateral breast cancer was most prevalent in the fifth decade (6/14) with the mean age of 47 years. 5) Film mammogram and sonomammogram showed findings of typical breast malignancies. There was no additional specific findings for each cancer in bilateral breast cancers which was different from unilateral cancers. Therefor, in the patients with unilateral breast cancer, possibility of the second lesion in the contralateral side must be considered and a close follow up observation should be done for at least 3 years

  8. Analyses of superficial and depth doses in intraoral radiology

    Energy Technology Data Exchange (ETDEWEB)

    Silva Santos de Oliveira, C.; Morais, R.P. de; Nascimento Souza, D. do [Universidade Federal de Sergipe - CCET - Dept. de Fisica, Sao Cristovao, SE (Brazil)

    2006-07-01

    In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film packet holder. The evaluation of the depth doses in the intraoral tissue was obtained using different acrylic plate thickness. The air kerma values have been evaluated with the ionization chamber located in the dental cone exit of the x-rays equipments. The integrated areas of the thermoluminescent glow curves showed coherent values when compared to the ones obtained with the ionization chamber and both methods presented a linear dependence with the exposition time. The analyses with films have allowed the evaluation of the beam scattering in the simulator apparatus. The studies had proven that the analysis of superficial dose and in depth used in dental radiology can be carried with thermoluminescent dosimeters. (authors)

  9. Analyses of superficial and depth doses in intraoral radiology

    International Nuclear Information System (INIS)

    Silva Santos de Oliveira, C.; Morais, R.P. de; Nascimento Souza, D. do

    2006-01-01

    In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO 4 :Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film packet holder. The evaluation of the depth doses in the intraoral tissue was obtained using different acrylic plate thickness. The air kerma values have been evaluated with the ionization chamber located in the dental cone exit of the x-rays equipments. The integrated areas of the thermoluminescent glow curves showed coherent values when compared to the ones obtained with the ionization chamber and both methods presented a linear dependence with the exposition time. The analyses with films have allowed the evaluation of the beam scattering in the simulator apparatus. The studies had proven that the analysis of superficial dose and in depth used in dental radiology can be carried with thermoluminescent dosimeters. (authors)

  10. Bilateral renal calculi

    Science.gov (United States)

    Sreenevasan, G

    1974-01-01

    Bilateral renal calculi were present in 114 (10.7%) of 1,070 cases of proved urinary calculus admitted to the Urological Department of the General Hospital, Kuala Lumpur, during the period November 1968—May 1973. The management of bilateral renal calculi is discussed with reference to the first 100 cases in this series. The introduction of renography has greatly facilitated the decision as to which kidney should be operated on first. The management of patients with and without uraemia is discussed and the use of the modified V and V—Y incisions for the removal of staghorn calculi is described. Complications and results are briefly reviewed. ImagesFig. 1Fig. 4Fig. 6Fig. 7 PMID:4845653

  11. Bilateral chronic subdural hematoma

    DEFF Research Database (Denmark)

    Andersen-Ranberg, Nina Christine; Rom Poulsen, Frantz; Bergholt, Bo

    2017-01-01

    OBJECTIVE Bilateral chronic subdural hematoma (bCSDH) is a common neurosurgical condition frequently associated with the need for retreatment. The reason for the high rate of retreatment has not been thoroughly investigated. Thus, the authors focused on determining which independent predictors...... are associated with the retreatment of bCSDH with a focus on surgical laterality. METHODS In a national database of CSDHs (Danish Chronic Subdural Hematoma Study) the authors retrospectively identified all bCSDHs treated in the 4 Danish neurosurgical departments over the 3-year period from 2010 to 2012...... that a separated hematoma density and the absence of postoperative drainage were independent predictors of retreatment. CONCLUSIONS In bCSDHs bilateral surgical intervention significantly lowers the risk of retreatment compared with unilateral intervention and should be considered when choosing a surgical...

  12. Bilateral Wilms' tumor

    International Nuclear Information System (INIS)

    Malcolm, A.W.; Jaffe, N.; Folkman, M.J.; Cassady, J.R.

    1980-01-01

    Twenty children with bilateral Wilms' tumor were presented to the Children's Hospital Medical Center and Children's Cancer Research Foundation, Sidney Farber Cancer Institute, and Joint Center for Radiation Therapy (CHMC-CCRF, SFCI, JCRT) from January 1, 1956 to December 31, 1976. Of these 20, 16 had simultaneous and 4 had metachronous disease on presentation. All patients were treated with surgery, radiation and chemotherapy. Of the 16 patients with simultaneous disease, 10 (63%) are alive and free of disease 12+ to 175+ months post diagnosis and treatment, with median follow-up of 121 months. There were no long-term survivors in the metachronous group; all were dead of disease within 21 months from initial presentation of original tumor. With these data we relate prognosis to extent of disease and discuss a general approach to the management of bilateral Wilms' tumor

  13. Multilateral and bilateral agreements

    International Nuclear Information System (INIS)

    Koponen, H.

    1993-01-01

    Finland has made both multilateral and bilateral agreements on the exchange of information related to radiation safety. The first arrangements for international agreements and exchange of information were made after the Chernobyl accident. In 1987, Finland joined the convention on early notification of a nuclear power accident coordinated by International Atomic Energy Agency. The convention is applied to accidents that cause of may cause emissions of radioactive substances that might affect the radiation safety of another country. Besides the convention on early notification, some other individual agreements have also been made. These include the International Nuclear Event Scale (INES) system and power companies own information exchange systems. Finland has conducted bilateral agreements with the Nordic countries and the Soviet Union on the notification of accidents and exchange of nuclear power plant information. Today, Russia answers for the Soviet Union's contractual obligations. (orig.)

  14. Bilateral renal artery variation

    OpenAIRE

    Üçerler, Hülya; Üzüm, Yusuf; İkiz, Z. Aslı Aktan

    2014-01-01

    Each kidney is supplied by a single renal artery, although renal artery variations are common. Variations of the renal arteryhave become important with the increasing number of renal transplantations. Numerous studies describe variations in renalartery anatomy. Especially the left renal artery is among the most critical arterial variations, because it is the referred side forresecting the donor kidney. During routine dissection in a formalin fixed male cadaver, we have found a bilateral renal...

  15. File: International bilateral relations

    International Nuclear Information System (INIS)

    Feltin, Ch.; Rabouhams, J.; Bravo, X.; Rousseau, M.; Le Breton, S.; Saint Raymond, Ph.; Brigaud, O.; Pertuis, V.; McNair, J.; Sayers, M.R.; Bye, R.; Scherrer, J.

    1998-01-01

    Since its creation in 1973, the Authority of Safety was assigned missions in the international field with following objectives: to develop information exchanges with its foreign counterpart, to make know and to explain the French approach and practice; to give to concerned countries the useful information on french nuclear facilities situated near the border; This file shows with some examples, how bilateral relations allow to fill up these objectives and how the French Authority got the foreign experience. (N.C.)

  16. Recent advances in dental optics - Part I: 3D intraoral scanners for restorative dentistry

    Science.gov (United States)

    Logozzo, Silvia; Zanetti, Elisabetta M.; Franceschini, Giordano; Kilpelä, Ari; Mäkynen, Anssi

    2014-03-01

    Intra-oral scanning technology is a very fast-growing field in dentistry since it responds to the need of an accurate three-dimensional mapping of the mouth, as required in a large number of procedures such as restorative dentistry and orthodontics. Nowadays, more than 10 intra-oral scanning devices for restorative dentistry have been developed all over the world even if only some of those devices are currently available on the market. All the existing intraoral scanners try to face with problems and disadvantages of traditional impression fabrication process and are based on different non-contact optical technologies and principles. The aim of this publication is to provide an extensive review of existing intraoral scanners for restorative dentistry evaluating their working principles, features and performances.

  17. Skeletal and soft tissue changes and stability in cleft lip and palate patients after distraction osteogenesis using a new intraoral maxillary device.

    Science.gov (United States)

    Ansari, Edward; Tomat, Catherine; Kadlub, Natacha; Diner, Patrick A; Bellocq, Thomas; Vazquez, Marie-Paule; Picard, Arnaud

    2015-04-01

    The authors have recently reported on the use of an internal maxillary distraction device. In this study, we report on the hard and soft tissue movements achieved with this intraoral distraction device, and the stability changes after distraction osteogenesis for maxillary hypoplasia in patients with cleft lip and palate. Ten male patients with severe hypoplasia of the maxilla, with complete uni- or bilateral cleft lip and palate were included. The mean age of the patients at the time of operation was 11.91 years (±3.41). To evaluate the distraction process and stability, superimpositions on the preoperative lateral cephalograms were performed. The mean follow-up (FU) was 15.42 months (±3.94). Cephalometric measurements at all of the maxillary hard and soft tissue points improved significantly. Maxillary point A was advanced by 8.25 mm (±3.17; P distraction soft tissue point A' had advanced 7.10 mm (±2.69; P distraction. Maxillary horizontal relapse at point A was 14.1% at FU. Vertical relapse was not significant. This rigid intraoral distraction device can be successfully used in the correction of severe maxillary hypoplasia. The marked aesthetic improvement and low psychological encumbrance make this device viable for the treatment of cleft-related hypoplasia of the maxilla. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  18. Idiopathic bilateral male breast abscess.

    Science.gov (United States)

    Sinha, Rajan Kumar; Sinha, Mithilesh Kumar; Gaurav, Kumar; Kumar, Amar

    2014-03-10

    A 38-year-old man presented with bilateral breast swelling, along with pain and redness for 7 days. Bilateral axillary nodes were also palpable; which were multiple and discrete. A provisional diagnosis of bilateral breast abscess was made with suspicion of underlying malignancy. Incision and drainage through subareolar incision was performed and the adjoining tissue was excised and sent for histopathological examination.

  19. A comparative evaluation of intraoral and extraoral digital impressions: An in vivo study.

    Science.gov (United States)

    Sason, Gursharan Kaur; Mistry, Gaurang; Tabassum, Rubina; Shetty, Omkar

    2018-01-01

    The accuracy of a dental impression is determined by two factors: "trueness" and "precision." The scanners used in dentistry are relatively new in market, and very few studies have compared the "precision" and "trueness" of intraoral scanner with the extraoral scanner. The aim of this study was to evaluate and compare accuracy of intraoral and extraoral digital impressions. Ten dentulous participants (male/female) aged 18-45 years with an asymptomatic endodontically treated mandibular first molars with adjacent teeth present were selected for this study. The prepared test tooth was measured using a digital Vernier caliper to obtain reference datasets. The tooth was then scanned using the intraoral scanner, and the extraoral scans were obtained using the casts made from the impressions. The datasets were divided into four groups and then statistically analyzed. The test tooth preparation was done, and dimples were made using a round diamond point on the bucco-occlusal, mesio-occlusal, disto-occlusal, and linguo-occlusal lines angles, and these were used to obtain reference datasets intraorally using a digital Vernier caliper. The test tooth was then scanned with the IO scanner (CS 3500, Carestream dental) thrice and also impressions were made using addition silicone impression material (3M™ ESPE) and dental casts were poured in Type IV dental stone (Kalrock-Kalabhai Karson India Pvt. Ltd., India) which were later scanned with the EO scanner (LAVA™ Scan ST Design system [3M™ ESPE]) thrice. The Datasets obtained from Intraoral and Extraoral scanner were exported to Dental Wings software and readings were obtained. Repeated measures ANOVA test was used to compare differences between the groups and independent t -test for comparison between the readings of intraoral and extraoral scanner. Least significant difference test was used for comparison between reference datasets with intraoral and extraoral scanner, respectively. A level of statistical significance of P

  20. Validation of 3D documentation of palatal soft tissue shape, color, and irregularity with intraoral scanning.

    Science.gov (United States)

    Deferm, Julie T; Schreurs, Ruud; Baan, Frank; Bruggink, Robin; Merkx, Matthijs A W; Xi, Tong; Bergé, Stefaan J; Maal, Thomas J J

    2018-04-01

    The purpose of this study was to assess the feasibility of 3D intraoral scanning for documentation of palatal soft tissue by evaluating the accuracy of shape, color, and curvature. Intraoral scans of ten participants' upper dentition and palate were acquired with the TRIOS® 3D intraoral scanner by two observers. Conventional impressions were taken and digitized as a gold standard. The resulting surface models were aligned using an Iterative Closest Point approach. The absolute distance measurements between the intraoral models and the digitized impression were used to quantify the trueness and precision of intraoral scanning. The mean color of the palatal soft tissue was extracted in HSV (hue, saturation, value) format to establish the color precision. Finally, the mean curvature of the surface models was calculated and used for surface irregularity. Mean average distance error between the conventional impression models and the intraoral models was 0.02 ± 0.07 mm (p = 0.30). Mean interobserver color difference was - 0.08 ± 1.49° (p = 0.864), 0.28 ± 0.78% (p = 0.286), and 0.30 ± 1.14% (p = 0.426) for respectively hue, saturation, and value. The interobserver differences for overall and maximum surface irregularity were 0.01 ± 0.03 and 0.00 ± 0.05 mm. This study supports the hypothesis that the intraoral scan can perform a 3D documentation of palatal soft tissue in terms of shape, color, and curvature. An intraoral scanner can be an objective tool, adjunctive to the clinical examination of the palatal tissue.

  1. Intra-oral electron therapy for carcinoma of the oral cavity using transparent acrylic tubes

    International Nuclear Information System (INIS)

    Terashima, Hiromi; Nakata, Hajime; Yoshiura, Takao; Ogawa, Masato; Yoshida, Akio; Ikemura, Kunio

    1986-01-01

    Intra-oral electron therapy for carcinoma of the oral cavity is a well-established treatment modality. However, the conventional metallic tubes were inconvenient to use because the irradiation field had to be confirmed by a side mirror. We devised transparent acrylic tubes which enable the positioning easy by confirming the tumor and irradiation field directry. Seven cases of various intra-oral carcinomas were treated with these new transparent acrylic tubes and good results were obtained. (author)

  2. Patient doses during intra-oral radiography in dental offices

    International Nuclear Information System (INIS)

    Sakaino, Rie; Harata, Yasuo; Okano, Tomohiro; Sato, Kenji; Yosue, Takashi; Nishikawa, Keiichi; Sano, Tsukasa; Kobayashi, Ikuo

    2011-01-01

    Measurement of patient entrance dose (PED) and dose area product (DAP) at various dental offices in the Tokyo bay area and comparison of PEDs with the existing diagnostic reference levels recommended in the United Kingdom (UK). The survey included 28 dental clinics categorized by the type of intra-oral radiography used. PED was measured by placing an optically stimulated luminescence dosimeter (OSLD) at the tip of the cone. Exposure parameters were those used for the adult mandibular molar region in the respective clinics. The OSLD readings were calibrated using an ionizing chamber manufactured according to standards of the Japan Quality Assurance Organization. The area (A), of the X-ray beam, was calculated by exposing an X-ray film placed at the tip of the cone and measuring the exposed area. Then the DAP was calculated as the product of PED times A. The PED estimated at various dental clinics differed by a factor of 120. The mean, minimum, maximum, median and third quartile values of PEDs were 4.99, 0.18, 21.7, 3.60 and 5.76 mGy, respectively. At 60-70 kV, PEDs observed in clinics using digital imaging systems were below 2.1 mGy which was lower than that of clinics using films that were E-speed or faster. It was also observed that PEDs were directly proportional to the tube current and exposure time. The mean, minimum, maximum, median and third quartile of DAPs were 13.0, 0.45, 61.4, 9.34 and 13.4 cGy cm 2 , respectively. The DAP values showed a linear correlation coefficient of 0.99 with PED values. Measurement of PED and DAP using OSLD and X-ray film can play a useful role in optimization of radiation protection for patients during intra-oral radiography. This method can be conveniently applied to set up diagnostic reference levels by carrying out mass surveys in Japan. (author)

  3. Fatal bilateral dioctophymatosis.

    Science.gov (United States)

    Li, Gang; Liu, Caigang; Li, Fang; Zhou, Maoyi; Liu, Xiangyong; Niu, Yuanjie

    2010-12-01

    Dioctophyma renale is a parasite that frequently occurs in animals but rarely in humans. The present report describes the clinical observations of a D. renale infection in a 51-yr-old woman. Its clinical signs and diagnostic findings were unspecific until giant worms were observed in the urine and histological findings confirmed it was a D. renale infection. She refused treatment and died of bilateral renal function failure. This is the first confirmed report to follow the natural progression of D. renale infection in a human. Here, we discuss a conservative therapeutic approach and features associated with this parasitic infection.

  4. Recurrent Bilateral Focal Myositis.

    Science.gov (United States)

    Nagafuchi, Hiroko; Nakano, Hiromasa; Ooka, Seido; Takakuwa, Yukiko; Yamada, Hidehiro; Tadokoro, Mamoru; Shimojo, Sadatomo; Ozaki, Shoichi

    This report describes a rare case of recurrent bilateral focal myositis and its successful treatment via methotrexate. A 38-year-old man presented myalgia of the right gastrocnemius in May 2005. Magnetic resonance imaging showed very high signal intensity in the right gastrocnemius on short-tau inversion recovery images. A muscle biopsy revealed inflammatory CD4+ cell-dominant myogenic change. Focal myositis was diagnosed. The first steroid treatment was effective. Tapering of prednisolone, however, repeatedly induced myositis relapse, which progressed to multiple muscle lesions of both lower limbs. Initiation of methotrexate finally allowed successful tapering of prednisolone, with no relapse in the past 4 years.

  5. Bilateral acoustic neuromas.

    Science.gov (United States)

    Anand, V T; Byrnes, D P; Walby, A P; Kerr, A G

    1993-10-01

    This article reviews 12 patients with bilateral acoustic neuromas. The sex incidence was equal and the mean age at diagnosis was 26.2 years. The family history was positive in nine of the patients. Five patients have had incomplete surgical removal of acoustic neuromas on both sides. Two of them are completely deaf and the other three have severe sensorineural hearing loss in one ear and no hearing in the other ear. In five patients the tumour on one side has been operated on and the other side is being observed with at least short-term preservation of good hearing. The remaining two patients died of intra-cranial complications, one of them post-operatively. Four patients developed facial palsy immediately following surgery and one developed facial weakness 6 months after surgery. Guidelines are discussed for the care of these patients including the timing of surgery and alternative treatment options (observation, radio-surgery and chemotherapy). This is essentially a group of young individuals who have had multiple operations for bilateral acoustic tumours and associated manifestations and for whom the disease and the sequelae of treatment can be tragic.

  6. Long-Term Stability of Pre-Orthodontic Orthognathic Bimaxillary Surgery Using Intraoral Vertical Ramus Osteotomy Versus Conventional Surgery.

    Science.gov (United States)

    Jeong, Jeong-Hwa; Choi, Sung-Hwan; Kim, Kee-Deog; Hwang, Chung-Ju; Lee, Sang-Hwy; Yu, Hyung-Seog

    2018-02-20

    The aim of the present study was to compare the long-term stability of bimaxillary surgery using an intraoral vertical ramus osteotomy (IVRO) with and without presurgical orthodontic treatment. The present retrospective study included 31 consecutive patients with skeletal Class III malocclusions who had undergone bimaxillary surgery (Le Fort I osteotomy and bilateral IVRO). Patients were divided into 2 groups based on treatment type: pre-orthodontic orthognathic surgery (POGS; n = 17) and conventional surgery with presurgical orthodontic treatment (CS; n = 14). Lateral cephalograms were obtained before surgery, 1 day after surgery, 1 month after surgery, 1 year after surgery, and 2 years after surgery to evaluate skeletal and soft tissue changes between the 2 groups. Data were analyzed using χ 2 tests, Mann-Whitney U tests, repeated-measures analyses of variance, and independent t tests. There was no significant difference in skeletal or soft tissue measurements-with the exception of the angle between the sella-and-nasion plane and the occlusal plane (SN-OP; P surgery. These findings suggest that POGS and CS have similar long-term stability in patients with skeletal Class III malocclusion. Copyright © 2018. Published by Elsevier Inc.

  7. First detection of lead in black paper from intraoral film

    Energy Technology Data Exchange (ETDEWEB)

    Guedes, Debora F.C., E-mail: defcg@usp.br [Departamento de Odontologia Restauradora, Faculdade de Odontologia de Ribeirao Preto, Universidade de Sao Paulo, Av. do Cafe, S/N, Monte Alegre, CEP 14040-904, Ribeirao Preto, SP (Brazil); Silva, Reginaldo S. [Departamento de Odontologia Restauradora, Faculdade de Odontologia de Ribeirao Preto, Universidade de Sao Paulo, Av. do Cafe, S/N, Monte Alegre, CEP 14040-904, Ribeirao Preto, SP (Brazil); Veiga, Marcia A.M.S. da [Departamento de Quimica, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Universidade de Sao Paulo, Av. do Cafe, S/N, Monte Alegre, CEP 14040-904, Ribeirao Preto, SP (Brazil); Pecora, Jesus D. [Departamento de Odontologia Restauradora, Faculdade de Odontologia de Ribeirao Preto, Universidade de Sao Paulo, Av. do Cafe, S/N, Monte Alegre, CEP 14040-904, Ribeirao Preto, SP (Brazil)

    2009-10-30

    Lead (Pb) contamination in the black paper that recovers intraoral films (BKP) has been investigated. BKP samples were collected from the Radiology Clinics of the Dental School of Ribeirao Preto, University of Sao Paulo, Brazil. For sake of comparison, four different methods were used. The results revealed the presence of high lead levels, well above the maximum limit allowed by the legislation. Pb contamination levels achieved after the following treatments: paper digestion in nitric acid, microwave treatment, DIN38414-54 method and TCLP method were 997 {mu}g g{sup -1}, 189 {mu}g g{sup -1}, 20.8 {mu}g g{sup -1}, and 54.0 {mu}g g{sup -1}, respectively. Flame atomic absorption spectrometry (FAAS) and inductively coupled plasma mass spectrometry (ICP-MS) were employed for lead determination according to the protocols of the applied methods. Lead contamination in used BKP was confirmed by scanning electron microscopy coupled with energy dispersive X-ray microanalysis (SEM-EDS). All the SEM imaging was carried out in the secondary electron mode (SE) and backscattered-electron mode (QBSD) following punctual X-ray fluorescence spectra. Soil contamination derived from this product revealed the urgent need of addressing this problem. These elevated Pb levels, show that a preliminary treatment of BKP is mandatory before it is disposed into the common trash. The high lead content of this material makes its direct dumping into the environment unwise.

  8. Characteristics of Kodak Insight, an F-speed intraoral film.

    Science.gov (United States)

    Ludlow, J B; Platin, E; Mol, A

    2001-01-01

    This study reports film speed, contrast, exposure latitude, resolution, and response to processing solution depletion of Kodak Insight intraoral film. Densitometric curves were generated by using International Standards Organization protocol. Additional curves were generated for Ultra-speed, Ektaspeed Plus, and Insight films developed in progressively depleted processing solutions. Eight observers viewed images of a resolution test tool for maximum resolution assessment. Images of an aluminum step-wedge were reviewed to determine useful exposure latitude. Insight's sensitivity in fresh automatic processor solutions places it in the F-speed group. An average gradient of 1.8 was found with all film types. Insight provided 93% of the useful exposure latitude of Ektaspeed Plus film. Insight maintained contrast in progressively depleted processing solutions. Like Ektaspeed Plus, Insight was able to resolve at least 20 line-pairs per millimeter. Under International Standards Organization conditions, Insight required only 77% of the exposure of Ektaspeed Plus film. Insight film provided stable contrast in depleted processing solutions.

  9. Evolution of diagnostic reference levels in Spanish intraoral radiology

    International Nuclear Information System (INIS)

    Alcaraz, M.; Velasco, F.; Martinez-Beneyto, Y.; Alcaraz-Saura, M.; Velasco, E.; Achel, G. D.; Canteras, M.

    2008-01-01

    A total of 16 175 official reports of quality assurance on dental radiodiagnostic surgeries from 16 Spanish autonomous regions compiled during 2002-09 were studied to determine the evolution of diagnostic reference levels (DRLs) for obtaining a diagnostic image in the normal conditions of clinical practice in Spanish dental clinics. A DRL of 3.1 mGy was set in 2009, which represents a 35.4 % decrease compared with the dose determined in 2002 (4.8 mGy). During the same period, the mean dose fell by only 17.2 %. The DRL recommended by the European Union in 2004 for intraoral radiology is 4 mGy, and this study shows that 83.4 % of the installations used a dose below this. Of the installations using indirect or direct digital systems 1.1 and 1.2 %, respectively, used doses higher than those recommended, while 14.2 % of those using radiographic film exceeded this limit. (authors)

  10. Geometric estimation method for x-ray digital intraoral tomosynthesis

    Science.gov (United States)

    Li, Liang; Yang, Yao; Chen, Zhiqiang

    2016-06-01

    It is essential for accurate image reconstruction to obtain a set of parameters that describes the x-ray scanning geometry. A geometric estimation method is presented for x-ray digital intraoral tomosynthesis (DIT) in which the detector remains stationary while the x-ray source rotates. The main idea is to estimate the three-dimensional (3-D) coordinates of each shot position using at least two small opaque balls adhering to the detector surface as the positioning markers. From the radiographs containing these balls, the position of each x-ray focal spot can be calculated independently relative to the detector center no matter what kind of scanning trajectory is used. A 3-D phantom which roughly simulates DIT was designed to evaluate the performance of this method both quantitatively and qualitatively in the sense of mean square error and structural similarity. Results are also presented for real data acquired with a DIT experimental system. These results prove the validity of this geometric estimation method.

  11. Fatigue failure of dental implants in simulated intraoral media.

    Science.gov (United States)

    Shemtov-Yona, K; Rittel, D

    2016-09-01

    Metallic dental implants are exposed to various intraoral environments and repetitive loads during service. Relatively few studies have systematically addressed the potential influence of the environment on the mechanical integrity of the implants, which is therefore the subject of this study. Four media (groups) were selected for room temperature testing, namely dry air, saliva substitute, same with 250ppm of fluoride, and saline solution (0.9%). Monolithic Ti-6Al-4V implants were loaded until fracture, using random spectrum loading. The study reveals that the only aggressive medium of all is the saline solution, as it shortens significantly the spectrum fatigue life of the implants. The quantitative scanning electron fractographic analysis indicates that all the tested implants grew fatigue cracks of similar lengths prior to catastrophic fracture. However, the average crack growth rate in the saline medium was found to largely exceed that in other media, suggesting a decreased fracture toughness. The notion of a characteristic timescale for environmental degradation was proposed to explain the results of our spectrum tests that blend randomly low and high cycle fatigue. Random spectrum fatigue testing is powerful technique to assess and compare the mechanical performance of dental implants for various designs and/or environments. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Intraoral Scanner Technologies: A Review to Make a Successful Impression

    Directory of Open Access Journals (Sweden)

    Raphaël Richert

    2017-01-01

    Full Text Available To overcome difficulties associated with conventional techniques, impressions with IOS (intraoral scanner and CAD/CAM (computer-aided design and manufacturing technologies were developed for dental practice. The last decade has seen an increasing number of optical IOS devices, and these are based on different technologies; the choice of which may impact on clinical use. To allow informed choice before purchasing or renewing an IOS, this article summarizes first the technologies currently used (light projection, distance object determination, and reconstruction. In the second section, the clinical considerations of each strategy such as handling, learning curve, powdering, scanning paths, tracking, and mesh quality are discussed. The last section is dedicated to the accuracy of files and of the intermaxillary relationship registered with IOS as the rendering of files in the graphical user interface is often misleading. This overview leads to the conclusion that the current IOS is adapted for a common practice, although differences exist between the technologies employed. An important aspect highlighted in this review is the reduction in the volume of hardware which has led to an increase in the importance of software-based technologies.

  13. First detection of lead in black paper from intraoral film

    International Nuclear Information System (INIS)

    Guedes, Debora F.C.; Silva, Reginaldo S.; Veiga, Marcia A.M.S. da; Pecora, Jesus D.

    2009-01-01

    Lead (Pb) contamination in the black paper that recovers intraoral films (BKP) has been investigated. BKP samples were collected from the Radiology Clinics of the Dental School of Ribeirao Preto, University of Sao Paulo, Brazil. For sake of comparison, four different methods were used. The results revealed the presence of high lead levels, well above the maximum limit allowed by the legislation. Pb contamination levels achieved after the following treatments: paper digestion in nitric acid, microwave treatment, DIN38414-54 method and TCLP method were 997 μg g -1 , 189 μg g -1 , 20.8 μg g -1 , and 54.0 μg g -1 , respectively. Flame atomic absorption spectrometry (FAAS) and inductively coupled plasma mass spectrometry (ICP-MS) were employed for lead determination according to the protocols of the applied methods. Lead contamination in used BKP was confirmed by scanning electron microscopy coupled with energy dispersive X-ray microanalysis (SEM-EDS). All the SEM imaging was carried out in the secondary electron mode (SE) and backscattered-electron mode (QBSD) following punctual X-ray fluorescence spectra. Soil contamination derived from this product revealed the urgent need of addressing this problem. These elevated Pb levels, show that a preliminary treatment of BKP is mandatory before it is disposed into the common trash. The high lead content of this material makes its direct dumping into the environment unwise.

  14. Digital subtraction radiographic evaluation of the standardize periapical intraoral radiographs

    International Nuclear Information System (INIS)

    Cho, Bong Hae; Nah, Kyung Soo

    1993-01-01

    The geometrically standardized intraoral radiographs using 5 occlusal registration material were taken serially from immediate, 1 day, 2, 4, 8, 12 and 16 weeks after making the bite blocks. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exaflex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  15. Diagnostic accuracy of insight intraoral film on dental caries

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Young Nam; Lee, Byung Do [Wonkwang University College of Medicine, Iksan (Korea, Republic of); Lee, Sang Rae [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    2004-03-15

    To compare the diagnostic accuracy of Kodak Insight film with other intra-oral films in the detection of dental caries. Periapical radiographs of 99 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were made on Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Kodak Insight films and automatically processed. Six dentists examined the presence of dental caries using a five-point confidence rating scale and compared the diagnostic accuracy by ROC (Receiver Operating Characteristic) analysis and ANOVA test. The sensitivity of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.84, 0.77, 0.75 and 0.79 respectively. The specificity of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.97, 0.95, 0.96 and 0.94 respectively. The mean ROC areas (Az) of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.917, 0.910, 0.894, 0.909 respectively. There was no significant differences between Az of Insight film and other films (p = 0.178). Theses results suggested that Kodak Insight film have the comparative diagnostic accuracy of dental caries with Ultraspeed and Ektaspeed films. (77)

  16. Diagnostic accuracy of insight intraoral film on dental caries

    International Nuclear Information System (INIS)

    Yoon, Young Nam; Lee, Byung Do; Lee, Sang Rae

    2004-01-01

    To compare the diagnostic accuracy of Kodak Insight film with other intra-oral films in the detection of dental caries. Periapical radiographs of 99 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were made on Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Kodak Insight films and automatically processed. Six dentists examined the presence of dental caries using a five-point confidence rating scale and compared the diagnostic accuracy by ROC (Receiver Operating Characteristic) analysis and ANOVA test. The sensitivity of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.84, 0.77, 0.75 and 0.79 respectively. The specificity of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.97, 0.95, 0.96 and 0.94 respectively. The mean ROC areas (Az) of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.917, 0.910, 0.894, 0.909 respectively. There was no significant differences between Az of Insight film and other films (p = 0.178). Theses results suggested that Kodak Insight film have the comparative diagnostic accuracy of dental caries with Ultraspeed and Ektaspeed films. (77)

  17. The need for national diagnostic reference levels: entrance surface dose measurement in intraoral radiography

    International Nuclear Information System (INIS)

    Mortazavi, S. M. J.; Shareghi, A.; Kavousi, A.; Ghiassi-Nejad, M.; Jafari-Zadeh, M.; Nazeri, F.; Mozdarani, H.

    2004-01-01

    Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection recommendations, the selection of a diagnostic reference level should be specific to a country or region. Critical organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low as reasonably achievable. To assist the development of DRLs for intraoral radiography, a National Radiation Protection Department-sponsored pilot study was carried out. Materials and methods: thermoluminescent dosimetry is widely acknowledged to be the recommended method for measuring entrance surface doses. In this study, entrance surface doses was measured using LiF thermoluminescent dosimeters on the skin (either mandibular or maxillary arcs) of 40 patients. Three thermoluminescent dosimetry chips were placed on the skin of each patient. The doses were averaged for each radiography and mean entrance surface doses of all patients calculated. Results: the mean ±SD entrance surface dose at the center of the beam on the patient's skin in intraoral radiography was 1.173 ±0.606 mGy (ranged from 0.01 o 0.40 m Gy). The mean entrance surface doses for male and female patients were 1.380± 0.823, and 1.004± 0.258 respectively. No statistically significant difference was found between these means. Despite its necessity , in national level , there is no published data on the diagnostic reference levels for intraoral radiography. However, the results obtained in this study are lower than those reported by investigators in other countries. Conclusion: in IR Iran , due to lack of large scale studies, no diagnostic reference levels have been set for X-ray diagnostic procedures. Due to lack of national diagnostic reference levels, it is not possible to clarify whether in intraoral radiographies any dose reduction techniques are needed. We intend to perform similar nationwide studies to set the

  18. Accuracy of intraoral digital impressions using an artificial landmark.

    Science.gov (United States)

    Kim, Jong-Eun; Amelya, Ami; Shin, Yooseok; Shim, June-Sung

    2017-06-01

    Intraoral scanners have been reported to have limited accuracy in edentulous areas. Large amounts of mobile tissue and the lack of obvious anatomic landmarks make it difficult to acquire a precise digital impression of an edentulous area with an intraoral scanner. The purpose of this in vitro study was to determine the effect of an artificial landmark on a long edentulous space on the accuracy outcomes of intraoral digital impressions. A mandibular model containing 4 prepared teeth and an edentulous space of 26 mm in length was used. A blue-light light-emitting diode tabletop scanner was used as a control scanner, and 3 intraoral scanners were used as experimental groups. Five scans were made using each intraoral scanner without an artificial landmark, and another 5 scans were performed after application of an artificial landmark (a 4×3 mm alumina material) on the edentulous area. The obtained datasets were used to evaluate trueness and precision. Without an artificial landmark on the edentulous area, the mean trueness for the intraoral scanner ranged from 36.1 to 38.8 μm and the mean precision ranged from 13.0 to 43.6 μm. With an artificial landmark on the edentulous area, accuracy was improved significantly: the mean trueness was 26.7 to 31.8 μm, and the mean precision was 9.2 to 12.4 μm. The use of an alumina artificial landmark in an edentulous space improved the trueness and precision of the intraoral scanners tested. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Bilateral tubercular mastitis

    Directory of Open Access Journals (Sweden)

    Kant Surya

    2007-01-01

    Full Text Available Breast tuberculosis is a rare form of tuberculosis. Moreover the disease is often overlooked and misdiagnosed as carcinoma or pyogenic abscess. Reports on breast tuberculosis from India have been few; reported incidence of breast tuberculosis amongst the total number of mammary conditions varies between 0.64 and 3.59 per cent. Bilateral involvement is still more uncommon (3%. Most accepted view for spread of infection is centripetal lymphatic spread as axillary node involvement was shown to occur in 50 to 75 per cent of cases of tubercular mastitis. Here we re-port a case of a young female who presented with draining sinuses in the breast and no axillary lymphadenopathy. Fine needle aspiration cytology (FNAC of breast lump showed evidence of granulomatous mastitis. She was given therapeutic trial of four drug antitubercular treatment. Both the lump disappeared and sinus healed after six months of antitubercular treatment. Thus a retrospective diagnosis of tu-bercular mastitis was made.

  20. Bilateral triple renal arteries

    International Nuclear Information System (INIS)

    Pestemalci, Turan; Yildiz, Yusuf Zeki; Yildirim, Mehmet; Mavi, Ayfer; Gumusburun, Erdem

    2009-01-01

    Knowledge of the variations of the renal artery has grown in importance with increasing numbers of renal transplants, vascular reconstructions and various surgical and radio logic techniques being performed in recent years. We report the presence of bilateral triple renal arteries, discovered on routine dissection of a male cadaver. On the right side, one additional renal artery originated from the abdominal aorta (distributed to superior pole of the kidney) and one other originated from the right common iliac artery (distributed to lower pole of the kidney). On the left side, both additional renal arteries originated from the abdominal aorta. Our observation has been compared with variations described in the literature and their clinical importance has been emphasized. (author)

  1. Idiopathic Bilateral Bloody Tearing

    Directory of Open Access Journals (Sweden)

    Emrullah Beyazyıldız

    2015-01-01

    Full Text Available Bloody tear is a rare and distinct clinic phenomenon. We report a case presenting with the complaint of recurrent episodes of bilateral bloody tearing. A 16-year-old girl presented to our clinic with complaint of bloody tearing in both eyes for 3 months. Bloody tearing was not associated with her menses. A blood-stained discharge from the punctum was not observed during the compression of both nasolacrimal ducts. Nasolacrimal passage was not obstructed. Imaging studies such as dacryocystography and gradient-echo magnetic resonance imaging (MRI of nasolacrimal canal were normal. Intranasal endoscopic evaluation was normal. We collected samples from bloody tears two times and pathological examination was performed. Pathological analysis showed lots of squamous cells and no endometrial cells; dysplastic cells were found. Further evaluations for underlying causes were unremarkable. No abnormalities were found in ophthalmologic, radiologic, and pathologic investigations. This condition is likely a rare abnormality and the least recognized aetiology for the idiopathic phenomenon.

  2. Bilateral Antepartum Mastitis

    Directory of Open Access Journals (Sweden)

    Peyman Alibeigi

    2010-12-01

    Full Text Available Antepartum mastitis is a rare condition, whereas postpartum orlactation mastitis is a common problem. This report introducesa case of complicated bilateral antepartum mastitis, which wastreated successfully by drain insertion and antibiotic therapy.The patient was a 23-year-old woman in the 23rd week of herfirst pregnancy. Her chief complaint was progressive swelling,redness and radicular pain in both breasts, which had beenstarted gradually from the 18th week of pregnancy. The patientwas admitted to hospital, and received oral and intravenous antibioticsempirically, which was not effective. The patient wastreated by drainage and oral antibiotic therapy. Based on theapproaches employed and the outcomes achieved it is suggestedthat early surgical insertion in the presence of fluid collection inantepartum mastitis will shorten hospitalization and course ofintravenous antibiotic therapy.Iran J Med Sci 2010; 35(4: 327-330.

  3. Stationary intraoral digital tomosynthesis using a carbon nanotube X-ray source array.

    Science.gov (United States)

    Shan, J; Tucker, A W; Gaalaas, L R; Wu, G; Platin, E; Mol, A; Lu, J; Zhou, O

    2015-01-01

    Intraoral dental tomosynthesis and closely related tuned-aperture CT (TACT) are low-dose three-dimensional (3D) imaging modalities that have shown improved detection of multiple dental diseases. Clinical interest in implementing these technologies waned owing to their time-consuming nature. Recently developed carbon nanotube (CNT) X-ray sources allow rapid multi-image acquisition without mechanical motion, making tomosynthesis a clinically viable technique. The objective of this investigation was to evaluate the feasibility of and produce high-quality images from a digital tomosynthesis system employing CNT X-ray technology. A test-bed stationary intraoral tomosynthesis unit was constructed using a CNT X-ray source array and a digital intraoral sensor. The source-to-image distance was modified to make the system comparable in image resolution to current two-dimensional intraoral radiography imaging systems. Anthropomorphic phantoms containing teeth with simulated and real caries lesions were imaged using a dose comparable to D-speed film dose with a rectangular collimation. Images were reconstructed and analysed. Tomosynthesis images of the phantom and teeth specimen demonstrated perceived image quality equivalent or superior to standard digital images with the added benefit of 3D information. The ability to "scroll" through slices in a buccal-lingual direction significantly improved visualization of anatomical details. In addition, the subjective visibility of dental caries was increased. Feasibility of the stationary intraoral tomosynthesis is demonstrated. The results show clinical promise and suitability for more robust observer and clinical studies.

  4. Side effects of intraoral devices for OSAS treatment.

    Science.gov (United States)

    Teixeira, Andressa Otranto de Britto; Andrade, Ana Luiza Ladeia; Almeida, Rhita Cristina da Cunha; Almeida, Marco Antonio de Oliveira

    2017-10-14

    Intraoral devices have increasingly assumed a key role in the treatment of obstructive sleep apnea syndrome, but there are limitations to their indication and side effects that result from their continuous use, as well as the use of the continuous positive airway pressure device. To evaluate the changes in dental positioning caused by the continuous use of mandibular advancement devices. A prospective longitudinal study with a sample of 15 patients, with evaluation of complete documentation after a mean time of 6.47 months, assessed changes in dental positioning due to the use of the Twin Block oral device for the treatment of patients with apnea. The following variables were evaluated: overjet, overbite, upper and lower intermolar distances, upper and lower intercanine distances, Little's irregularity index and the incisor mandibular plane angle. An intraclass correlation test was performed and a correlation index>0.08 was accepted. After verifying the normal sample distribution (Shapiro-Wilks), a parametric test was used (t test), with a significance level set at 5%. There was a decrease in the values of overjet, overbite and Little's irregularity index, whereas there was an increase in the lower intercanine distance and IMPA values. All these variables are influenced, at different levels, by the forward inclination of the lower incisors, an action that can be expected due to the force applied by the device on the dentition. The other variables did not show statistically significant differences. After a mean time of 6.47 months of use of the mandibular advancement device, there were statistically significant changes in the dental positioning, but they were not clinically relevant. However, it is relevant that this device is commonly in use over long periods of time, making the monitoring of these patients of the utmost importance for the duration of their therapy. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia C

  5. Úlcera corneal bilateral como consecuencia de malnutrición calórico-protéica y déficit de vitamina A en un paciente con alcoholismo crónico, pancreatitis crónica y colecistostomía Bilateral corneal ulceration as a result of energy-protein hyponutrition and vitamin A deficit in a patient with chronic alcoholism, chronic pancreatitis and cholecystostomy

    OpenAIRE

    S. Benítez Cruz; C. Gómez Candela; M. Ruiz Martín; A. I. Cos Blanco

    2005-01-01

    Desde el descubrimiento de las vitaminas ha existido un creciente interés por relacionar las vitaminas con ciertas enfermedades. Para la vitamina A en particular se ha determinado su singular importancia en múltiples funciones vitales y su relación con enfermedades tanto por déficit como por exceso esta ahora completamente demostrada. En países desarrollados las enfermedades por déficit vitamínicos han disminuido de manera importante; sin embargo en pacientes con características particulares ...

  6. A boy with bilateral SUNA

    DEFF Research Database (Denmark)

    Vuković Cvetković, Vlasta; Jensen, Rigmor Højland

    2017-01-01

    secondary causes should be searched for vigorously if there are bilateral symptoms. Despite a number of therapeutic trials, effective management for the majority of SUNA patients is not available at present. Management of SUNA is often difficult. Case We report the case of a young boy with bilateral SUNA...

  7. Silicosis with bilateral spontaneous pneumothorax

    Directory of Open Access Journals (Sweden)

    Fotedar Sanjay

    2010-01-01

    Full Text Available Presentation with simultaneous bilateral pneumothorax is uncommon and usually in the context of secondary spontaneous pneumothorax.The association of pneumothorax and silicosis is infrequent and most cases are unilateral. Bilateral pneumothorax in silicosis is very rare with just a few reports in medical literature.

  8. Bilateral persistent hyperplastic primary vitreous

    Directory of Open Access Journals (Sweden)

    Jain Tarun

    2009-01-01

    Full Text Available A case of bilateral persistent hyperplastic primary vitreous (PHPV in a 3-month-old male infant, who had bilateral leukokoria, is presented. The child was referred for imaging with a clinical suspicion of retinoblastoma. Gray-scale ultrasound evaluation revealed an echogenic band in the posterior segment of both globes, extending from the posterior surface of the lens capsule to the optic disc. Doppler examination revealed the presence of arterial flow in the band in both globes. Associated echogenic hemorrhage was also seen, which was confirmed by computed tomography. Most cases of PHPV are sporadic and unilateral, and bilateral PHPV is rare. The imaging features in this case suggest the diagnosis of bilateral PHPV and differentiate it from retinoblastoma. This entity, although infrequent, should be considered in the differential diagnosis while evaluating bilateral leukokoria.

  9. Intraoral pH and temperature during sleep with and without mouth breathing.

    Science.gov (United States)

    Choi, J E; Waddell, J N; Lyons, K M; Kieser, J A

    2016-05-01

    To measure and compare the intraoral pH and temperature of individuals during sleep with and without mouth breathing. Ten healthy participants [mean age = 25·8 (± 4·3)] wore a custom-made appliance fitted with a pH probe and thermocouple for two sets of 48 h. Continuous pH and temperature measurements were taken from the palatal aspect of the upper central incisors. To simulate mouth breathing during sleep, participants wore a nose clip for two nights of the four, with the first group (n = 5) wearing the nose clip during the first night and the rest (n = 5) wearing the nose clip during the second night of sleep to balance any potential bias from the wearing sequence. Both qualitative and quantitative analyses were conducted. The mean intraoral pH during daytime was 7·3 (± 0·4) and during sleep was 7·0 (± 0·5). The mean intraoral pH during sleep with mouth breathing was 6·6 (± 0·5), which was statistically significant compared with the normal sleep condition (P pH decreased slowly over the hours of sleep in all participants. When sleeping with forced mouth breathing, intraoral pH showed a greater fall over a longer period of time. The mean intraoral temperature was 33·1 °C (± 5·2) during daytime and 33·3 °C (± 6·1) during sleep, with no statistical significance between sleep with and without mouth breathing (P > 0·05). The results suggest that mouth breathing during sleep is related to a decrease in intraoral pH compared with normal breathing during sleep, and this has been proposed as a causal factor for dental erosion and caries. © 2015 John Wiley & Sons Ltd.

  10. Accuracy of Intraoral Digital Impressions for Whole Upper Jaws, Including Full Dentitions and Palatal Soft Tissues.

    Directory of Open Access Journals (Sweden)

    Ning Gan

    Full Text Available Intraoral digital impressions have been stated to meet the clinical requirements for some teeth-supported restorations, though fewer evidences were proposed for larger scanning range. The aim of this study was to compare the accuracy (trueness and precision of intraoral digital impressions for whole upper jaws, including the full dentitions and palatal soft tissues, as well as to determine the effect of different palatal vault height or arch width on accuracy of intraoral digital impressions. Thirty-two volunteers were divided into three groups according to the palatal vault height or arch width. Each volunteer received three scans with TRIOS intraoral scanner and one conventional impression of whole upper jaw. Three-dimensional (3D images digitized from conventional gypsum casts by a laboratory scanner were chose as the reference models. All datasets were imported to a specific software program for 3D analysis by "best fit alignment" and "3D compare" process. Color-coded deviation maps showed qualitative visualization of the deviations. For the digital impressions for palatal soft tissues, trueness was (130.54±33.95μm and precision was (55.26±11.21μm. For the digital impressions for upper full dentitions, trueness was (80.01±17.78μm and precision was (59.52±11.29μm. Larger deviations were found between intraoral digital impressions and conventional impressions in the areas of palatal soft tissues than that in the areas of full dentitions (p0.05, but arch width was found to have a significant effect on precision of intraoral digital impressions for full dentitions (p = 0.016. A linear correlation was found between arch width and precision of digital impressions for whole upper jaws (r = 0.326, p = 0.034 for palatal soft tissues and r = 0.485, p = 0.002 for full dentitions. It was feasible to use the intraoral scanner to obtain digital impressions for whole upper jaws. Wider dental arch contributed to lower precision of an intraoral

  11. Accuracy of Intraoral Digital Impressions for Whole Upper Jaws, Including Full Dentitions and Palatal Soft Tissues.

    Science.gov (United States)

    Gan, Ning; Xiong, Yaoyang; Jiao, Ting

    2016-01-01

    Intraoral digital impressions have been stated to meet the clinical requirements for some teeth-supported restorations, though fewer evidences were proposed for larger scanning range. The aim of this study was to compare the accuracy (trueness and precision) of intraoral digital impressions for whole upper jaws, including the full dentitions and palatal soft tissues, as well as to determine the effect of different palatal vault height or arch width on accuracy of intraoral digital impressions. Thirty-two volunteers were divided into three groups according to the palatal vault height or arch width. Each volunteer received three scans with TRIOS intraoral scanner and one conventional impression of whole upper jaw. Three-dimensional (3D) images digitized from conventional gypsum casts by a laboratory scanner were chose as the reference models. All datasets were imported to a specific software program for 3D analysis by "best fit alignment" and "3D compare" process. Color-coded deviation maps showed qualitative visualization of the deviations. For the digital impressions for palatal soft tissues, trueness was (130.54±33.95)μm and precision was (55.26±11.21)μm. For the digital impressions for upper full dentitions, trueness was (80.01±17.78)μm and precision was (59.52±11.29)μm. Larger deviations were found between intraoral digital impressions and conventional impressions in the areas of palatal soft tissues than that in the areas of full dentitions (pimpressions for palatal soft tissues was slightly better than that for full dentitions (p = 0.049). There was no significant effect of palatal vault height on accuracy of digital impressions for palatal soft tissues (p>0.05), but arch width was found to have a significant effect on precision of intraoral digital impressions for full dentitions (p = 0.016). A linear correlation was found between arch width and precision of digital impressions for whole upper jaws (r = 0.326, p = 0.034 for palatal soft tissues and r

  12. Accuracy of Intraoral Digital Impressions for Whole Upper Jaws, Including Full Dentitions and Palatal Soft Tissues

    Science.gov (United States)

    Gan, Ning; Xiong, Yaoyang; Jiao, Ting

    2016-01-01

    Intraoral digital impressions have been stated to meet the clinical requirements for some teeth-supported restorations, though fewer evidences were proposed for larger scanning range. The aim of this study was to compare the accuracy (trueness and precision) of intraoral digital impressions for whole upper jaws, including the full dentitions and palatal soft tissues, as well as to determine the effect of different palatal vault height or arch width on accuracy of intraoral digital impressions. Thirty-two volunteers were divided into three groups according to the palatal vault height or arch width. Each volunteer received three scans with TRIOS intraoral scanner and one conventional impression of whole upper jaw. Three-dimensional (3D) images digitized from conventional gypsum casts by a laboratory scanner were chose as the reference models. All datasets were imported to a specific software program for 3D analysis by "best fit alignment" and "3D compare" process. Color-coded deviation maps showed qualitative visualization of the deviations. For the digital impressions for palatal soft tissues, trueness was (130.54±33.95)μm and precision was (55.26±11.21)μm. For the digital impressions for upper full dentitions, trueness was (80.01±17.78)μm and precision was (59.52±11.29)μm. Larger deviations were found between intraoral digital impressions and conventional impressions in the areas of palatal soft tissues than that in the areas of full dentitions (pimpressions for palatal soft tissues was slightly better than that for full dentitions (p = 0.049). There was no significant effect of palatal vault height on accuracy of digital impressions for palatal soft tissues (p>0.05), but arch width was found to have a significant effect on precision of intraoral digital impressions for full dentitions (p = 0.016). A linear correlation was found between arch width and precision of digital impressions for whole upper jaws (r = 0.326, p = 0.034 for palatal soft tissues and r

  13. Prevalence and intraoral distribution of Candida albicans in Sjögren's syndrome.

    OpenAIRE

    Tapper-Jones, L; Aldred, M; Walker, D M

    1980-01-01

    An imprint culture technique has been employed to study the prevalence and intraoral distribution of Candida albicans in 16 patients with Sjögren's syndrome and in 16 healthy controls matched for age, sex, and dental status. The prevalence and intraoral density of C. albicans was found to be significantly higher at almost all sites in the Sjögren's patients than in the controls. The distribution of candida was also altered, being significantly higher in the floor of the mouth and anterior lab...

  14. Bilateral nephroblastoma - case report

    International Nuclear Information System (INIS)

    Luczynska, E.; Aniol, J.

    2008-01-01

    Wilms tumor is the most common renal tumor in children Synchronous bilateral Wilms tumor (BWT) accounts for 5% of all patients registered to the National Wilms Tumor Study Group (NWSTG). A 28-year-old female patient was presented to Oncology Institute with right kidney tumor. Her left kidney was resected due to Wilms tumor in the sixth month of her life. Abdominal ultrasound was performed and demonstrated a massive right kidney tumor. Then the abdominal CT was undertaken with the use of 16-slice CT scanner, revealing rotation displacement of the right kidney, with signs of compensative overgrowth and displaced upwards. In the lower and peripheral part of the kidney a nodular mass 7 X 10 X 9 cm in size was visible. The tumor was well-demarcated, showing heterogeneous contrast enhancement, extending from the inferio-lateral renal pole.The tumor was adjacent to iliopsoas muscle and abdominal cavity walls; no infiltration of those structures was noted. Described lesion surrounded inferio-medial part of the kidney, approaching kidney pelvis without infiltrating them. Supero-anterior and medial part of the kidney showed normal structure with correct contrasted urine excretion. Lymph nodes enlargement within periaortal area was not detected. Surgical procedure was performed resulting in excision of the tumor with kidney preservation. Histopathology examination revealed nephroblastoma. The tumor was surrounded by a thin, fibrous capsule. Surrounding parenchyma and far tissue were not involved. The CT examination performed 4 months after nephron sparing surgery revealed: right kidney of 137 X 51 mm in size, normally located, with correct structure and function. Multislice abdominal CT have clearly visualized the tumor of the single kidney, showing precise localization of the mass with relation to the kidney pelvis and vessels, allowing for nephron sparing surgical excision. (authors)

  15. Bilateral Olecranon Tophaceous Gout Bursitis

    Directory of Open Access Journals (Sweden)

    Güzelali Özdemir

    2017-01-01

    Full Text Available In this case, we present a patient with the diagnosis of bilateral olecranon tophaceous gout. After the surgical treatment, there was no limitation of range of motion or wound problem at 6th month control.

  16. Bilateral, independent juvenile nasopharyngeal angiofibroma

    DEFF Research Database (Denmark)

    Mørkenborg, Marie-Louise; Frendø, M; Stavngaard, T

    2015-01-01

    BACKGROUND: Juvenile nasopharyngeal angiofibroma is a benign, vascular tumour that primarily occurs in adolescent males. Despite its benign nature, aggressive growth patterns can cause potential life-threatening complications. Juvenile nasopharyngeal angiofibroma is normally unilateral, originating...... from the sphenopalatine artery, but bilateral symptoms can occur if a large tumour extends to the contralateral side of the nasopharynx. This paper presents the first reported case of true bilateral extensive juvenile nasopharyngeal angiofibroma involving clinically challenging pre-surgical planning...... embolisation. Radical removal performed as one-step, computer-assisted functional endoscopic sinus surgery was performed. The follow-up period was uncomplicated. CONCLUSION: This case illustrates the importance of suspecting bilateral juvenile nasopharyngeal angiofibroma in patients presenting with bilateral...

  17. Bilateral papillary renal cell carcinoma

    International Nuclear Information System (INIS)

    Gossios, K.; Vazakas, P.; Argyropoulou, M.; Stefanaki, S.; Stavropoulos, N.E.

    2001-01-01

    Papillary renal cell carcinoma is a subgroup of malignant renal epithelial neoplasms. We report the clinical and imaging findings of a case with multifocal and bilateral renal cell carcinoma which are nonspecific. (orig.)

  18. Bilateral internal laryngoceles mimicking asthma

    Directory of Open Access Journals (Sweden)

    Elif A Aksoy

    2013-01-01

    Full Text Available Laryngocele is an air-filled, abnormal dilation of the laryngeal saccule that extends upward within the false vocal fold, in communication with the laryngeal lumen. A case of 43-year-old male with bilateral internal laryngoceles, who has been treated as asthma for 4 years, is presented. The patient had dyspnea, cough, and excessive phlegm for a month and a late onset stridor. Flexible nasopharyngolaryngoscopy showed bilateral cystic enlargements of the false vocal folds and true vocal folds could not be visualized. Laryngeal CT without contrast enhancement showed bilateral internal laryngoceles. Submucosal total excision of bilateral cystic masses including parts of false vocal folds was performed. The symptoms resolved immediately after surgery. Although the incidence of internal laryngocele is rare, it should be remembered in the differential diagnosis of upper airway problems and diagnostic flexible nasopharnygolaryngoscopy is routinely indicated for airway evaluation in at-risk patients.

  19. Radiografia intraoral e convencional da hemiarcada superior direita de gatos domésticos Intraoral and convencional radiography of the right maxilla hemiarcade of domestic cats

    Directory of Open Access Journals (Sweden)

    A.C. Nepomuceno

    2013-02-01

    Full Text Available A proposta com este trabalho foi avaliar a hemiarcada superior direita de gatos domésticos por meio de técnicas radiográficas odontológicas do paralelismo, empregando-se filmes intraorais aos posicionadores de Han Shin. As imagens obtidas por essa metodologia foram correlacionadas com as técnicas radiográficas convencionais (extraorais, com o intuito de se estabelecerem vantagens ou desvantagens para detectar possíveis afecções dentais e periodontais. Foram utilizados 30 gatos, sem raça definida, 17 machos e 13 fêmeas, faixa etária entre um e três anos, confinados em gatis do Departamento de Zootecnia da Universidade Federal de Lavras/MG. Com os animais sob anestesia geral, foram realizadas radiografias da hemiarcada superior direita, incluindo três incisivos, um canino, três pré-molares e um molar em radiografias intraorais e extraorais. As imagens radiográficas foram analisadas e efetuaram-se comparações qualitativas entre pares intraorais e convencionais dos mesmos animais. Para se estabelecer a técnica radiográfica dental mais bem adaptada, foram realizadas análises estatísticas pelo teste de McNemar (qui-quadrado modificado. A técnica intraoral mostrou ser superior à extraoral (PThe aim of this research was to evaluate the right maxilla hemiarcade of cats through parallel dental radiographic techniques, applying Han Shin intraoral film positioner. Images obtained with this method were correlated with conventional radiographic techniques (extraoral. The goal was to establish the advantages and disadvantages to detect possible dental and periodontal diseases. Thirty mixed breed cats were evaluated, 17 males and 13 females, ages one to three years old, confined in catteries in the Department of Zootecnia of the Federal University of Lavras/MG. Radiographies of the right maxilla were taken with the animals under general anesthesia, and three incisors, one canine, three premolars and one molar teeth were included in the

  20. Simultaneous bilateral patellar tendon rupture ?

    OpenAIRE

    Moura, Diogo Lino; Marques, Jos? Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2016-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a s...

  1. Bilateral sarkoidose i glandula parotis

    DEFF Research Database (Denmark)

    Hahn, Pernille; Krogdahl, Annelise; Godballe, Christian

    2012-01-01

    We describe an unusual case of sarcoidosis in which the patient presented with a bilateral swelling of the parotid salivary glands and no other manifestation of the disease. Sarcoidosis is a multisystem granulomatous disorder of unknown cause in which there may be multiple exocrine involvement......, including the salivary glands. This case emphasises the importance of including sarcoidosis in the differential diagnosis of bilateral parotid swelling....

  2. Reliability of intra-oral camera using teledentistry in screening of oral diseases – Pilot study

    Directory of Open Access Journals (Sweden)

    Kalyana Chakravarthy Pentapati

    2017-04-01

    Conclusion/recommendations: Intra-oral camera was shown to be a reliable tool to identify common oral diseases. Further studies involving applications like sealant retention, pre-malignant lesions, recurrent apthae, gingival recession and dental malocclusion and effectiveness in regular screening are needed.

  3. Development of a computer simulation system of intraoral radiography using perspective volume rendering of CT data

    International Nuclear Information System (INIS)

    Okamura, Kazutoshi; Tanaka, Takemasa; Yoshiura, Kazunori; Tokumori, Kenji; Kanda, Shigenobu

    2002-01-01

    The purpose of this study was to evaluate the usefulness of a computer simulation system for intraoral radiography as an educational aid for radiographic training for dental students. A dried skull was scanned with a multidetector CT, and the series of slice data was transferred to a workstation. A software AVS Express Developer was used to construct the x-ray projected images from the CT slice data. Geometrical reproducibilities were confirmed using numerical phantoms. We simulated images using the perspective projection method with an average value algorithm on this software. Simulated images were compared with conventional film images projected from the same geometrical positions, including eccentric projection. Furthermore, to confirm the changes of the image depending on the projection angles of the x-ray beam, we constructed simulation images in which the root apexes were enhanced with the maximum value algorithm. Using this method, high resolution simulated images with perspective projection, as opposed to parallel, were constructed. Comparing with conventional film images, all major anatomic components could be visualized easily. Any intraoral radiographs at an arbitrary angular projection could be simulated, which was impossible in the conventional training schema for radiographic technique. Therefore, not only standard projected images but also eccentric projections could be displayed. A computer simulation system of intraoral radiography with this method may be useful for training in intraoral radiographic technique for dental students. (author)

  4. The tongue microbiome in healthy subjects and patients with intraoral halitosis

    NARCIS (Netherlands)

    Seerangaiyan, Kavitha; van Winkelhoff, Arie Jan; Harmsen, Hermie J. M.; Rossen, John W. A.; Winkel, Edwin G.

    2017-01-01

    Intra-oral halitosis (IOH) is an unpleasant odor emanating from the oral cavity. It is thought that the microbiota of the dorsal tongue coating plays a crucial role in this condition. The aim of the study was to investigate the composition of the tongue microbiome in subjects with and without IOH. A

  5. The optimum circular field size for dental radiography with intraoral films

    NARCIS (Netherlands)

    Straaten, F.J. van; Aken, J. van

    Intraoral radiographs are often made with circular fields to irradiate the film, and in many instances these fields are much larger than the film. The feasibility of reducing a circular radiation field without increasing the probability of excessive cone cutting was evaluated clinically, and an

  6. Factors influencing the design of aiming devices for intraoral radiography and their practical application

    NARCIS (Netherlands)

    Aken, J. van; Verhoeven, J.W.

    Intraoral roentgenograms can be made according to the long-tube paralleling technique utilizing aiming devices. These instruments consist of a bite block, an indicator rod, and a collimator plate. For the position of the film in relation to the bite block surface, the following data are decisive and

  7. Fluoride and urea chewing gums in an intra-oral experimental caries model

    NARCIS (Netherlands)

    Sjogren, K; Ruben, J; Lingstrom, P; Lundberg, AB; Birkhed, D

    2002-01-01

    The aim of the present investigation was to evaluate the effect of sugar-free chewing gums containing fluoride (F) and urea in an intra-oral experimental caries model. Placebo chewing gums (without any active ingredient) and no gum served as controls. Fifteen subjects participated in a cross-over,

  8. Recurrent intraoral HSV-1 infection: A retrospective study of 58 immunocompetent patients from Eastern Europe.

    Science.gov (United States)

    Tovaru, Serban; Parlatescu, Ioanina; Tovaru, Mihaela; Cionca, Lucia; Arduino, Paolo-Giacomo

    2011-03-01

    To revise the clinical features of the recurrent intraoral herpetic infection (RIOH) with respect to precipitating factors, demographic, clinical features and outcome. Fifty-eight, unrelated Caucasian, immunocompetent patients with positive laboratory test for intraoral Herpes simplex virus infection were studied. The mean age in the women's group (n=42) was 41.23 years (± 21.73) and in the men's group was 32.25 years (±15.68). Possible trigger factors were identified in 9 cases (15.5%). General symptoms were noted in 20 cases (34.48%). Most of patients in this study presented multiple lesions. 14 patients had vermillion lesions associated with intraoral lesions. In most of the cases both fixed and mobile mucosa was concomitantly involved. Treatment was prescribed in order to control the symptoms and to shorten the evolution with minimal side effects. Intraoral secondary herpetic infection could be polymorphous and sometimes associated with general symptoms. The recognition of its atypical features may prevent unnecessary and costly investigations and treatments for unrelated though clinically similar-appearing disorders.

  9. Accuracy of four different digital intraoral scanners: effects of the presence of orthodontic brackets and wire.

    Science.gov (United States)

    Jung, Yoo-Ran; Park, Ji-Man; Chun, Youn-Sic; Lee, Kkot-Nim; Kim, Minji

    The objective of this study was to compare the accuracy of four different digital intraoral scanners and the effects of buccal brackets and orthodontic wire. For this study, three sets of models (Control model, BKT model with buccal bracket, and WBKT model with buccal bracket and orthodontic wire) were scanned using four different types of intraoral scanners: E4D dentist, iTero, Trios, and Zfx IntraScan. The mesiodistal width of the teeth, intercanine width, and intermolar width measured by four scanners were compared. Three-dimensional (3D) images of the brackets were taken using the four scanners. Data were analyzed with one-way ANOVA, independent t test, and post-hoc Tukey test at a significance level of P brackets and orthodontic wire. Comparison of 3D bracket images scanned by the four scanners showed differences in image distortion among the scanners. Bracket characteristics did not affect the 3D bracket images. The four intraoral scanners used in this study differed in accuracy. However, the results acquired by iTero and Trios were more reliable. Effects of buccal brackets and orthodontic wire on the 3D images taken by intraoral scanners were not clinically significant.

  10. Absorbed and effective dose from periapical radiography by portable intraoral x-ray machine

    International Nuclear Information System (INIS)

    Cho, Jeong Yeon; Han, Won Jeong; Kim, Eun Kyung

    2007-01-01

    The purpose of this study was to measure the absorbed dose and to calculate the effective dose for periapical radiography done by portable intraoral x-ray machines. 14 full mouth, upper posterior and lower posterior periapical radiographs were taken by wall-type 1 and portable type 3 intraoral x-ray machines. Thermoluminescent dosemeters were placed at 23 sites at the layers of the tissue-equivalent ART woman phantom for dosimetry. Average tissue absorbed dose and radiation weighted dose were calculated for each major anatomical site. Effective dose was calculated using 2005 ICRP tissue weighted factors. On 14 full mouth periapical radiographs, the effective dose for wall-type x-ray machine was 30 Sv; for portable x-ray machines were 30 Sv, 22 Sv, 36 Sv. On upper posterior radiograph, the effective dose for wall-type x-ray machine was 4 Sv; for portable x-ray machines doses were 4 Sv, 3 Sv, 5 Sv. On lower posterior radiograph, the effective dose for wall type x-ray machine was 5 Sv; for portable x-ray machines doses were 4 Sv, 4 Sv, 5 Sv. Effective doses for periapical radiographs performed by portable intraoral x-ray machines were similar to doses for periapical radiographs taken by wall type intraoral x-ray machines

  11. Computer-aided analysis of digital dental impressions obtained from intraoral and extraoral scanners.

    Science.gov (United States)

    Bohner, Lauren Oliveira Lima; De Luca Canto, Graziela; Marció, Bruno Silva; Laganá, Dalva Cruz; Sesma, Newton; Tortamano Neto, Pedro

    2017-11-01

    The internal and marginal adaptation of a computer-aided design and computer-aided manufacturing (CAD-CAM) prosthesis relies on the quality of the 3-dimensional image. The quality of imaging systems requires evaluation. The purpose of this in vitro study was to evaluate and compare the trueness of intraoral and extraoral scanners in scanning prepared teeth. Ten acrylic resin teeth to be used as a reference dataset were prepared according to standard guidelines and scanned with an industrial computed tomography system. Data were acquired with 4 scanner devices (n=10): the Trios intraoral scanner (TIS), the D250 extraoral scanner (DES), the Cerec Bluecam intraoral scanner (CBIS), and the Cerec InEosX5 extraoral scanner (CIES). For intraoral scanners, each tooth was digitized individually. Extraoral scanning was obtained from dental casts of each prepared tooth. The discrepancy between each scan and its respective reference model was obtained by deviation analysis (μm) and volume/area difference (μm). Statistical analysis was performed using linear models for repeated measurement factors test and 1-way ANOVA (α=.05). No significant differences in deviation values were found among scanners. For CBIS and CIES, the deviation was significantly higher (PDentistry. Published by Elsevier Inc. All rights reserved.

  12. Validity of scoring caries and primary molar hypomineralization (DMH) on intraoral photographs.

    Science.gov (United States)

    Elfrink, M E C; Veerkamp, J S J; Aartman, I H A; Moll, H A; Ten Cate, J M

    2009-11-01

    The aims of this study were to assess whether intraoral photographs could be used to score caries and hypomineralization on primary molars (Using adapted Molar Incisor Hypomineralization (MIH)-criteria), and also to assess the reliability and validity in 3-7 year-old Dutch children of these scores by comparing them to direct clinical scorings. Cross-sectional study. In this study 62 children (38.7% girls) with a mean age of 4.96 years (SD 1.27) participated. The children were rated clinically by their own dentist (authors JV or ME) for caries reaching the dentine in their primary molars (WHO criteria) and also for primary molar hypomineralization using the adapted MIH-criteria. For the intraoral photographs, a digital intraoral camera was used. The two paediatric dentists rated all the intraoral photographs on caries and hypomineralizations on the second primary molars, using the same criteria for the clinical scoring as for the scoring of the photographs. They scored independently, at least 2 weeks after the initial clinical scoring to avoid observational bias with the clinical scoring. This clinical observation was used as the gold standard from which sensitivity, specificity, Positive Predictive Value (PPV), Negative Predictive Value (NPV) and the Positive and Negative Likelihood Ratio were computed. To test the intra-observer agreement 25 % of the photographs were scored again, at least 2 weeks after the initial scoring of the images. Inter- and intra-observer agreement were tested using Cohen's Kappa. The mean prevalence of clinically detected caries at tooth level was 46.7% and the mean prevalence of clinically detected hypomineralizations in second primary molars at tooth level was 21.8%. The sensitivity of assessing caries using intraoral photographs was 85.5%, the specificity 83.6%, the positive likelihood ratio 5.2 and the negative likelihood ratio was 0.17. For Primary Molar Hypomineralization (DMH) the sensitivity was 72.3%, the specificity 92.8%, the

  13. Clinical Acceptability of the Internal Gap of CAD/CAM PD-AG Crowns Using Intraoral Digital Impressions

    Science.gov (United States)

    Kim, Tae-Gyung; Kim, Sungtae; Lee, Jae-Hoon

    2016-01-01

    The purpose of this study was to compare the internal gap between CAD/CAM palladium-silver crowns and cast gold crowns generated from intraoral digital versus conventional impressions and to determine the clinical acceptability. Nickel-chrome master dies were made from the prepared resin tooth with the conventional impression method (n = 40). For ICC (Intraoral, CAD/CAM) group, 10 intraoral digital impressions were made, and 10 CAD/CAM crowns of a PD-AG (palladium-silver) machinable alloy were generated. For IC (Intraoral, Cast) group, 10 gold crowns were cast from ten intraoral digital impressions. For CCC (Conventional, CAD/CAM) group, 10 CAD/CAM PD-AG crowns were made using the conventional impression method. For CC (Conventional, Cast) group, 10 gold crowns were fabricated from 10 conventional impressions. One hundred magnifications of the internal gaps of each crown were measured at 50 points with an optical microscope and these values were statistically analyzed using a two-way analysis of variance (α = 0.05). The internal gap of the intraoral digital impression group was significantly larger than in the conventional impression group (P 0.05). Within the limitations of this in vitro study, crowns from intraoral digital impressions showed larger internal gap values than crowns from conventional impressions. PMID:28018914

  14. Clinical Acceptability of the Internal Gap of CAD/CAM PD-AG Crowns Using Intraoral Digital Impressions

    Directory of Open Access Journals (Sweden)

    Tae-Gyung Kim

    2016-01-01

    Full Text Available The purpose of this study was to compare the internal gap between CAD/CAM palladium-silver crowns and cast gold crowns generated from intraoral digital versus conventional impressions and to determine the clinical acceptability. Nickel-chrome master dies were made from the prepared resin tooth with the conventional impression method (n=40. For ICC (Intraoral, CAD/CAM group, 10 intraoral digital impressions were made, and 10 CAD/CAM crowns of a PD-AG (palladium-silver machinable alloy were generated. For IC (Intraoral, Cast group, 10 gold crowns were cast from ten intraoral digital impressions. For CCC (Conventional, CAD/CAM group, 10 CAD/CAM PD-AG crowns were made using the conventional impression method. For CC (Conventional, Cast group, 10 gold crowns were fabricated from 10 conventional impressions. One hundred magnifications of the internal gaps of each crown were measured at 50 points with an optical microscope and these values were statistically analyzed using a two-way analysis of variance (α=0.05. The internal gap of the intraoral digital impression group was significantly larger than in the conventional impression group (P0.05. Within the limitations of this in vitro study, crowns from intraoral digital impressions showed larger internal gap values than crowns from conventional impressions.

  15. Validation of assessment of intraoral digital photography for evaluation of dental restorations in clinical research.

    Science.gov (United States)

    Signori, Cácia; Collares, Kauê; Cumerlato, Catarina B F; Correa, Marcos B; Opdam, Niek J M; Cenci, Maximiliano S

    2018-04-01

    The aim of this study was to investigate the validity of assessment of intraoral digital photography in the evaluation of dental restorations. Intraoral photographs of anterior and posterior restorations were classified based on FDI criteria according to the need for intervention: no intervention, repair and replacement. Evaluations were performed by an experienced expert in restorative dentistry (gold standard evaluator) and 3 trained dentists (consensus). The clinical inspection was the reference standard method. The prevalence of failures was explored. Cohen's kappa statistic was used. Validity was accessed by sensitivity, specificity, likelihood ratio and predictives values. Higher prevalence of failed restorations intervention was identified by the intraoral photography (17.7%) in comparison to the clinical evaluation (14.1%). Moderate agreement in the diagnosis of total failures was shown between the methods for the gold standard evaluator (kappa = 0.51) and consensus of evaluators (kappa = 0.53). Gold standard evaluator and consensus showed substantial and moderate agreement for posterior restorations (kappa = 0.61; 0.59), and fair and moderate agreement for anterior restorations (kappa = 0.36; 0.43), respectively. The accuracy was 84.8% in the assessment by intraoral photographs. Sensitivity and specificity values of 87.5% and 89.3% were found. Under the limits of this study, the assessment of digital photography performed by intraoral camera is an indirect diagnostic method valid for the evaluation of dental restorations, mainly in posterior teeth. This method should be employed taking into account the higher detection of defects provided by the images, which are not always clinically relevant. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. A controlled evaluation of oral screen effects on intra-oral pressure curve characteristics.

    Science.gov (United States)

    Knösel, Michael; Jung, Klaus; Kinzinger, Gero; Bauss, Oskar; Engelke, Wilfried

    2010-10-01

    The purpose of this study was to quantify the impact of oral screen (OS) application on intra-oral pressure characteristics in three malocclusion groups. Fifty-six randomly recruited participants (26 males and 30 females) who met the inclusion criteria of either an Angle Class I occlusal relationships or Angle Class II1 or II2 malocclusions, were assigned by dentition to group I (n = 31), group II1 (n = 12), or group II2 (n = 13). Two 3 minute periods of intra-oral pressure monitoring were conducted on each participant, using two different oral end fittings connected to a piezo-resistive relative pressure sensor: (1) a flexible OS and (2) a small-dimensioned air-permeable end cap (EC), which was placed laterally in the premolar region, thus recording intra-oral pressure independent of the influence of the OS. Pressure curve characteristics for both periods and between the malocclusion groups were evaluated with reference to the frequency of swallowing peaks, duration, and altitude of negative pressure plateau phases and the area under the pressure curve. Statistical analysis was undertaken using analysis of variance (ANOVA), the Wilcoxon Mann-Whitney test, and spearman correlation coefficient. A median number of two peaks (median height -20.9 mbar) and three plateau phases (median height of -2.3 mbar) may be regarded as normative for normal occlusion subjects during a 3 minute period, at rest. OS application raised the median average duration and height of intra-oral negative pressure plateau phases in the II1 subjects, exceeding those of group I, but less than the plateau duration in group II2. Median peak heights were distinctively lower in groups I and II1 during OS application. It is concluded that additional training for extension of intra-oral pressure phases may be a promising approach to pre-orthodontic Class II division 1 treatment.

  17. 38 CFR 4.26 - Bilateral factor.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Bilateral factor. 4.26... DISABILITIES General Policy in Rating § 4.26 Bilateral factor. When a partial disability results from disease... disability. The bilateral factor will be applied to such bilateral disabilities before other combinations are...

  18. Bilateral Endoscopic Medial Maxillectomy for Bilateral Inverted Papilloma

    Science.gov (United States)

    Kodama, Satoru; Kawano, Toshiaki; Suzuki, Masashi

    2012-01-01

    Inverted papilloma (IP) is a benign tumor of the nasal cavity and paranasal sinuses that is unilateral in most cases. Bilateral IP, involving both sides of the nasal cavity and sinuses, is extremely rare. This paper describes a large IP that filled in both sides of the nasal cavity and sinuses, mimicking association with malignancy. The tumor was successfully treated by bilateral endoscopic medial maxillectomy (EMM). The patient is without evidence of the disease 24 months after surgery. If preoperative diagnosis does not confirm the association with malignancy in IP, endoscopic sinus surgery (ESS) should be selected, and ESS, including EMM, is a good first choice of the treatment for IP. PMID:22953103

  19. Oral Bilateral Collagenous Fibroma: A previously unreported case and literature review.

    Science.gov (United States)

    Vasconcelos, Ana-Carolina; Gomes, Ana-Paula; Tarquinio, Sandra; Abduch-Rodrigues, Eduardo; Mesquita, Ricardo; Silva, Karine

    2018-01-01

    Collagenous fibroma, also known as desmoplastic fibroblastoma, is a rare benign slow growing tumor particularly uncommon in the oral cavity. The aim of this study was to analyze the clinical and histopathological features of an oral collagenous fibroma as well as to compare this data with those reported in an English-literature review. The thirteenth case of collagenous fibroma in the oral cavity and the first to present clinically as a bilateral mass was described. A 48-years-old female patient was referred to a School of Dentistry, complaining about an asymptomatic swelling on the hard palate, lasting around ten years. The intraoral examination revealed two well-defined mass, bilaterally in the hard palate. An excisional biopsy was performed. Microscopically, the connective tissue consisted of dense collagen bundles in which were seen scarcely distributed spindle-shaped to stellate fibroblastic cells. Blood vessels were few, as well as inflammatory cells. Immunohistochemical staining was positive for vimentin, α-smooth muscle actin and factor XIIIa and negative for S-100, CD68, CD34, HHF35, desmin and AE1/AE3. The patient remains disease-free 24 months after excision. In conclusion, oral collagenous fibroma should be included in the differential diagnosis of bilateral sessile nodules in the oral cavity. Key words: Connective tissue, mouth diseases, mouth neoplasms, oral diagnosis, oral pathology.

  20. Bilateral spontaneous hemotympanum: Case report

    Directory of Open Access Journals (Sweden)

    Economou Nicolas C

    2006-10-01

    Full Text Available Abstract Background The most common causes of hemotympanum are therapeutic nasal packing, epistaxis, blood disorders and blunt trauma to the head. Hemotympanum is characterized as idiopathic, when it is detected in the presence of chronic otitis media. A rare case of spontaneous bilateral hemotympanum in a patient treated with anticoagulants is presented herein. Case presentation A 72-year-old male presented with acute deterioration of hearing. In the patient's medical history aortic valve replacement 1 year before presentation was reported. Since then he had been administered regularly coumarinic anticoagulants, with INR levels maintained between 3.4 and 4.0. Otoscopy revealed the presence of bilateral hemotympanum. The audiogram showed symmetrical moderately severe mixed hearing loss bilaterally, with the conductive component predominating. Tympanograms were flat bilaterally with absent acoustic reflexes. A computerized tomography scan showed the presence of fluid in the mastoid and middle ear bilaterally. Treatment was conservative and consisted of a 10-day course of antibiotics, anticongestants and temporary interruption of the anticoagulant therapy. After 3 weeks, normal tympanic membranes were found and hearing had returned to previous levels. Conclusion Anticoagulant intake should be included in the differential diagnosis of hemotympanum, because its detection and appropriate treatment may lead to resolution of the disorder.

  1. Achondroplasia Associated with Bilateral Keratoconus

    Directory of Open Access Journals (Sweden)

    Ammar M. Al Mahmood

    2012-01-01

    Full Text Available We report a rare case of bilateral keratoconus in association with achondroplasia. A 26-year-old male, with a known case of achondroplasia, complained of bilateral gradual deterioration in vision for the past few years. Slit lamp biomicroscopy showed bilateral central corneal protrusion and stromal thinning at the apex consistent with keratoconus. a trial of hard contact lens fitting failed to improve VA in the left eye (LE. Right eye (RE improved to 20/25. The patient underwent penetrating keratoplasty (PKP in his LE. Twenty-seven months postoperatively, uncorrected visual acuity (UCVA was 20/30. Ophthalmologists should be aware that patients with achondroplasia who complain of poor vision should be suspected of having keratoconus once other more common conditions are ruled out.

  2. The accuracy of the CAD system using intraoral and extraoral scanners for designing of fixed dental prostheses.

    Science.gov (United States)

    Shimizu, Sakura; Shinya, Akikazu; Kuroda, Soichi; Gomi, Harunori

    2017-07-26

    The accuracy of prostheses affects clinical success and is, in turn, affected by the accuracy of the scanner and CAD programs. Thus, their accuracy is important. The first aim of this study was to evaluate the accuracy of an intraoral scanner with active triangulation (Cerec Omnicam), an intraoral scanner with a confocal laser (3Shape Trios), and an extraoral scanner with active triangulation (D810). The second aim of this study was to compare the accuracy of the digital crowns designed with two different scanner/CAD combinations. The accuracy of the intraoral scanners and extraoral scanner was clinically acceptable. Marginal and internal fit of the digital crowns fabricated using the intraoral scanner and CAD programs were inferior to those fabricated using the extraoral scanner and CAD programs.

  3. High fear of intra-oral injections: prevalence and relationship to dental fear and dental avoidance among 10- to 16-yr-old children.

    Science.gov (United States)

    Berge, Karin G; Agdal, Maren L; Vika, Margrethe; Skeie, Marit S

    2016-12-01

    The present study aimed to: (i) estimate the prevalence of self-reported high fear of intra-oral injections, high blood-injury fear, and injection fear; (ii) explore the overlap between high fear of intra-oral injections and high fear of dental treatment; and (iii) evaluate the possible consequence of high fear of intra-oral injections in terms of avoidance of dental care. The sample included 1,441 subjects, 10- to 16-yr of age, attending elementary schools in a county of Norway. Data were collected using questionnaires that were completed in classrooms. The survey instruments used were the Intra-Oral Injection Fear-scale, the Children's Fear Survey Schedule-Dental Subscale, the Injection Phobia scale for children, and the Mutilation Questionnaire for children. In total, 13.9% of the children reported high intra-oral injection fear. A strong association was found between fear of intra-oral injections and dental fear. When an intra-oral injection was needed, 10.6% would avoid dental treatment. In multiple regression analysis, high intra-oral injection fear was found to be associated with avoidance of dental treatment (OR = 6.52; 95% CI: 3.99-10.67). It was concluded that high fear of intra-oral injections was prevalent and might lead to avoidance of necessary dental treatment. Hence, intra-oral injection fear should be addressed before treatment of dental fear. © 2016 Eur J Oral Sci.

  4. Simultaneous bilateral patellar tendon rupture.

    Science.gov (United States)

    Moura, Diogo Lino; Marques, José Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2017-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  5. Simultaneous bilateral patellar tendon rupture

    Directory of Open Access Journals (Sweden)

    Diogo Lino Moura

    Full Text Available ABSTRACT Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  6. Un caso de hipertrofia bilateral de quelas en el cangrejo violinista Uca cumulanta (Decapoda: Ocypodidae

    Directory of Open Access Journals (Sweden)

    Carlos Lira

    2006-12-01

    Full Text Available Un macho de Uca cumulanta con hipertrofia bilateral de quelas fue capturado durante en la Laguna de La Restinga, Isla de Margarita, Venezuela. Ambas quelas eran subiguales en tamaño y se asemejaban al quelípedo mayor de los machos normales.A case of bilateral cheliped hypertrophya crab Uca cumulanta (Decapoda: Ocypodidae. An adult male of Uca cumulanta with bilateral cheliped hypertrophy was found during a collection of crabs at La Restinga Lagoon, Margarita Island, Venezuela. Both chelipeds were sub equal in size, regarding the major cheliped of a normal male. Rev. Biol. Trop. 54 (Suppl. 3: 117-119. Epub 2007 Jan. 15.

  7. Parálisis diafragmática bilateral. Presentación de un caso Bilateral diaphragmatic paralysis

    Directory of Open Access Journals (Sweden)

    Jorge Carnot Pereira

    2012-04-01

    Full Text Available La parálisis diafragmática bilateral es una entidad muy infrecuente en la clínica, debido a diferentes entidades con capacidad de lesionar el nervio frénico. El compromiso respiratorio que produce requiere cuidado especializado. Este es el primer caso reportado en nuestra literatura a consecuencia de hernias cervicales múltiples. Se presenta un caso de un paciente de 43 años, con antecedentes de salud, exatleta de alto rendimiento, que ingresó en nuestro servicio, con disnea de 5 meses de evolución, que aumentó progresivamente en intensidad hasta mantenerlo en ortopnea constante, fue estudiado exhaustivamente hasta llegar a diagnostico definido y derivarlo al servicio de Neurocirugía para su solución definitiva. La importancia del tema que se presenta es que se describe una presentación rara de parálisis diafragmática bilateral, a consecuencia de hernias discales cervicales múltiples.Bilateral diaphragmatic paralysis is a rare condition in clinical practice due to different entities that can damage phrenic nerve. The resulting respiratory compromise requires medical special care. This is the first case reported in our medical literature caused by multiple cervical hernias. A 43 year-old patient having health history, high performance ex-athlete, admitted in the service with 5-month evolution of dyspnea which progressively increased in intensity up to maintain him in permanent orthopnea, thorough studies were conducted to the definite diagnosis and he was transferred to Neurosurgery Service to a definite solution. A rare presentation of a bilateral diaphragmatic paralysis resulting from multiple cervical hernias gives importance to the topic.

  8. Trombosis venosa profunda bilateral en una puérpera

    Directory of Open Access Journals (Sweden)

    Leydis Bárbara Ferreiro Hernández

    2015-05-01

    Full Text Available Se describe el caso clínico de una paciente de 29 años de edad, con antecedente de prolapso de la válvula mitral, quien a los 16 días de parida se le diagnosticó trombosis venosa profunda ileofemoral del lado derecho y a los 15 días, aúncon tratamiento anticoagulante, comenzó con trombosis venosa profunda del lado izquierdo, así como también con cuadro clínico sugestivo de tromboembolismo pulmonar.Se concluyó como una enfermedad tromboembólica venosa, dada por la presencia de trombosis venosa profunda bilateral.No hubo oclusión de la vena cava inferior, los resultados de la ecografía Doppler fueron positivos en ambos miembros y la respuesta al tratamiento anticoagulante resultó adecuada

  9. Evidence for use of intraoral scanners under clinical conditions for obtaining full-arch digital impressions is insufficient.

    Science.gov (United States)

    Khraishi, Hadil; Duane, Brett

    2017-03-01

    Data sourcesPubMed, Scopus, Cochrane Library, Web of Science, Embase. Relevant papers were also searched from the reference lists of selected studies. A web search of current manufacturers of intraoral scanners.Study selectionStudies with full-arch digital impressions recorded intraorally that tested any of the following outcomes; validity, repeatability, reproducibility, time efficiency. Patient acceptance of digital impressions were considered for the review.Data extraction and synthesisInitially, only titles of the papers identified from the databases were screened, then further screening of the abstracts of the selected titles was carried out. Then finally, full text articles of the selected abstracts were read and only relevant articles were included in the review. Two examiners assessed the quality of the chosen articles using the QUADAS checklist. Any disagreement was resolved by discussion between the two examiners.ResultsOnly eight studies were found that carried out full-arch intraoral scanning. Four studies reported on validity, repeatability and reproducibility of digital measurements. These studies were included in the qualitative assessment. Two intraoral scanners were tested, Lava COS and iTero. In assessing scanning times and patient perception, six and four studies were included, respectively. A decrease in the scanning time was noted as the operator gained experience.ConclusionsThe literature lacks sufficient evidence to comment on the use of intraoral scanners under clinical conditions. Further studies are needed to properly assess the reliability, accuracy, reproducibility and scanning times of intraoral scans.

  10. Intraoral dental radiography: experimental study and clinical use in two horses and a llama

    International Nuclear Information System (INIS)

    O'Brien, R.T.

    1996-01-01

    A technique for intraoral radiography of the maxillary cheek teeth in large animals using strips of nonscreen and commercial dental x-ray film is described. The method was initially tested using horse cadaver heads and subsequently on three large animal patients with signs of dental disease. Limitations of the described technique include necessity for general anesthesia, special x-ray film and manual developing. Additionally, the need for very accurate adjustment of incident beam angle, beam centering point and depth in the oral cavity provide a major technical challenge. After becoming famillar with the technique, the major limitation was increased time for manual film developing. The images provided by nonscreen technique were subjectively superior. The anatomic detail of the apical and periodontal regions of the teeth was better than on survey radiographs. Nonscreen intraoral technique should be considered for anesthetized large animal patients with signs of dental disease

  11. Co-occurrence of intraoral hemangioma and port wine stain: A rare case

    Directory of Open Access Journals (Sweden)

    Prasanna Kumar Rao

    2012-01-01

    Full Text Available Hemangiomas are neoplastic proliferations of endothelial cells, characterized by a period of growth after birth, and eventual spontaneous involution. The course can be uneventful with spontaneous resolution; or it may be marked by complications such as infection, bleeding, ulceration, visual defects and feeding difficulties. Apart from these, rare life-threatening complications such as congestive heart failure and consumption coagulopathy may also be seen. Although hemangiomas commonly occur in the head and neck region, intraoral occurrence is relatively rare. A port wine stain is defined as a macular telangiectatic patch which is present at birth and remains throughout life. They may be localized or extensive, affecting a whole limb. This article reports a rare case of co-occurrence of port wine stain with intraoral hemangioma.

  12. Use of digital impression systems with intraoral scanners for fabricating restorations and fixed dental prostheses.

    Science.gov (United States)

    Takeuchi, Yoshimasa; Koizumi, Hiroyasu; Furuchi, Mika; Sato, Yohei; Ohkubo, Chikahiro; Matsumura, Hideo

    2018-01-01

    Accurate impressions are essential in fabri-cating dental restorations and fixed dental prostheses. During the last decade, digital impression systems have improved substantially. This review discusses the accuracy of digital impression systems for fabrication of dental restorations and fixed dental prostheses. A literature search in PubMed was performed for the period from July 2010 through June 2017. The search keywords were Cerec, digital impression, direct digitalization, indirect digitalization, and intraoral scanner. Only relevant studies are summarized and discussed in this review. In general, the latest systems have considerably reduced the time required for impression making, and the accuracy and marginal fit of digital impression systems have recently improved. Restorations and fixed dental prostheses fabricated with currently available digital impression systems and intraoral scanners exhibit clinically acceptable ranges of marginal gap in both direct and indirect procedures.

  13. The combined use of radiotherapy and immunochemotherapy with Krestin for intra-oral cancer

    International Nuclear Information System (INIS)

    Komatsu, Yukihisa; Kuroda, Manabu

    1981-01-01

    Interstitial irradiation with needles 226 Ra was performed on 3 patients with intra-oral cancer. Krestin, an immunotherapeutic agent, was administered three times a day. All patients were also given 600 mg of FT-207/day as adjuvant chemotherapy. Moreover, one of them was also given 0.75 mg/day of eskinon every day. As parameters of immunological competence, PPD and PHA intracutaneous responses and the lymphocyte count in peripheral blood were used. Ulcers of intra-oral cancer were completely heated and there was no lymph node enargement. Though there were changes in PPD intracutaneous responses among three patients, positive responses were maintained. Absolute values of the lymphocyte count in peripheral blood were almost above 1,000/mm 3 in patients treated with both krestin and FT-207, but those in a patient treated with additional eskinon decreased gradually to 450/mm 3 . (Tsunoda, M.)

  14. A Study of the Resolution of Dental Intraoral X-Ray Machines

    International Nuclear Information System (INIS)

    Kim, Seon Ju; Chung, Hyon De

    1990-01-01

    The purpose of this study was to assess the resolution and focal spot size of dental X-ray machines. Fifty dental X-ray machines were selected for measuring resolution and focal spot size. These machines were used in general dental clinics. The time on installation of the X-ray machine varies from 1 years to 10 years. The resolution of these machines was measured with the test pattern. The focal spot size of these machines was measured with the star test pattern. The following results were obtained: 1. The resolution of dental intraoral X-ray machines was not significantly changed in ten years. 2. The focal spot size of dental intraoral X-ray machines was not significantly increased in ten years. The statistical analysis between the mean focal spot size and nominal focal spot size was significant at the 0.05 level about the more than 3 years used machines.

  15. ABOUT EXPERIENCE OF THE DR.SUNI1800 INTRAORAL RADIOVISIOGRAPH AND OPENDENTAL EMR-SYSTEM INTEGRATION

    Directory of Open Access Journals (Sweden)

    A. V. Semenets

    2015-05-01

    Full Text Available Digital radiovisiography is widely used X-ray technology in the dentistry practice for the diagnostics currently. The brief overview of the market of the digital radiovisiographs and related radiology information systems is given. High hardware and software prices are often combined with insufficient and low-quality support services. The Dr.Suni 1800 intraoral radiovisiograph installation problems due to the outdated software are described. The abilities of the open-source free software usage in the radiology diagnoses tasks are shown. The existing methodology of the Dr.Suni 1800 intraoral radiovisiograph and the OpenDental medical information system integration is improved. An updated step-by-step integration procedure is presented. The Windows 7 (32-bit edition compatibility is confirmed.

  16. Intraoral Digital Impressions for Virtual Occlusal Records: Section Quantity and Dimensions

    Directory of Open Access Journals (Sweden)

    Eneko Solaberrieta

    2016-01-01

    Full Text Available The purpose of this study was to locate the 3D spatial position mandibular cast and determine its occlusal contacts in a novel way by using an intraoral scanner as part of the virtual occlusal record procedure. This study also analyzes the requirements in quantity and dimensions of the intraoral virtual occlusal record. The results showed that the best section combination consists of 2 lateral and frontal sections, the width of this section being that of 2 teeth (24 mm × 15 mm. This study concluded that this procedure was accurate enough to locate the mandibular cast on a virtual articulator. However, at least 2 sections of the virtual occlusal records were necessary, and the best results were obtained when the distance between these sections was maximum.

  17. Effect of Software Version on the Accuracy of an Intraoral Scanning Device.

    Science.gov (United States)

    Haddadi, Yasser; Bahrami, Golnosh; Isidor, Flemming

    2018-04-06

    To investigate the impact of software version on the accuracy of an intraoral scanning device. A master tooth was scanned with a high-precision optical scanner and then 10 times with a CEREC Omnicam scanner with software versions 4.4.0 and 4.4.4. Discrepancies were measured using quality control software. Mean deviation for 4.4.0 was 36.2 ± 35 μm and for 4.4.4 was 20.7 ± 14.2 μm (P ≤ .001). Software version has a significant impact on the accuracy of an intraoral scanner. It is important that researchers also publish the software version of scanners when publishing their findings.

  18. Prevalence and intraoral distribution of Candida albicans in Sjögren's syndrome.

    Science.gov (United States)

    Tapper-Jones, L; Aldred, M; Walker, D M

    1980-03-01

    An imprint culture technique has been employed to study the prevalence and intraoral distribution of Candida albicans in 16 patients with Sjögren's syndrome and in 16 healthy controls matched for age, sex, and dental status. The prevalence and intraoral density of C. albicans was found to be significantly higher at almost all sites in the Sjögren's patients than in the controls. The distribution of candida was also altered, being significantly higher in the floor of the mouth and anterior labial sulcus in the Sjögren's group. There was an approximate inverse relationship between candida populations and rate of salivary flow. Mean candida densities were found to be significantly higher in those Sjögren's patients with detectable serum rheumatoid factor in the serum. However, patients with primary Sjögren's syndrome had significantly higher mean candida densities compared with patients with secondary Sjögren's syndrome.

  19. Intraoral Digital Impressions for Virtual Occlusal Records: Section Quantity and Dimensions

    Science.gov (United States)

    Solaberrieta, Eneko; Garmendia, Asier; Brizuela, Aritza; Otegi, Jose Ramon; Pradies, Guillermo; Szentpétery, Andras

    2016-01-01

    The purpose of this study was to locate the 3D spatial position mandibular cast and determine its occlusal contacts in a novel way by using an intraoral scanner as part of the virtual occlusal record procedure. This study also analyzes the requirements in quantity and dimensions of the intraoral virtual occlusal record. The results showed that the best section combination consists of 2 lateral and frontal sections, the width of this section being that of 2 teeth (24 mm × 15 mm). This study concluded that this procedure was accurate enough to locate the mandibular cast on a virtual articulator. However, at least 2 sections of the virtual occlusal records were necessary, and the best results were obtained when the distance between these sections was maximum. PMID:26881226

  20. Bilateral tension pneumothorax after acupuncture.

    Science.gov (United States)

    Mohammad, Nurashikin

    2018-04-19

    Acupuncture is an ancient complementary medicine which is currently used worldwide. Many serious adverse events have been reported which include a spectrum of mild-to-fatal complications. However, the level of awareness with regard to complications is still low both to physicians and patients. We report a 63-year-old who presented with acute shortness of breath 2 hours after having had acupuncture. On examination, there was absent breath sound heard on the left lung and slightly reduced breath sound on the right lung. She had type 1 respiratory failure. Urgent chest radiograph confirmed bilateral pneumothorax which was more severe on the left with tension pneumothorax and mediastinal shift. Chest tubes were inserted bilaterally after failed needle aspiration attempts. Subsequently, the pneumothoraces resolved, and she was discharged well. The bilateral pneumothoraces caused by acupuncture were curable but could have been potentially fatal if diagnosis was delayed. This case report adds to the limited current literature on the complications of acupuncture leading to bilateral pneumothoraces. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Bilateral breast in brothers - abreast

    Directory of Open Access Journals (Sweden)

    Altamash Mohammed Yusuf Shaikh

    2013-01-01

    Full Text Available Gynecomastia is a common occurrence in pubertal age group, and is physiological in up to 65 percent of cases. When occurs in the family it should be investigated in order not to miss on a treatable etiology. Two brothers within the same family, presenting with bilateral gynecomastia of different causes and requiring different treatment are presented.

  2. Afectación ocular severa bilateral por déficit de vitamina A

    OpenAIRE

    Ruiz-Martín, MM; Boto-de-los-Bueis, A; Romero-Martín, R

    2005-01-01

    Caso clínico: Se presenta un paciente con pancreatitis crónica alcohólica con una queratitis ulcerativa periférica (QUP) en el ojo derecho (OD) y una úlcera estromal necrotizante e hifema en el ojo izquierdo (OI) asociadas a una malnutrición calórico-proteica con déficit de vitaminas liposolubles. Discusión: Aunque es raro en los países desarrollados, debe considerarse el déficit de vitamina A ante afectación corneal bilateral en pacientes alcohólicos, con patología gastrointestinal, pancreát...

  3. Accuracy of 3-dimensional curvilinear measurements on digital models with intraoral scanners.

    Science.gov (United States)

    Mack, Spencer; Bonilla, Tammy; English, Jeryl D; Cozad, Benjamin; Akyalcin, Sercan

    2017-09-01

    Our objectives were to evaluate and compare the digital dental models generated from 2 commercial intraoral scanners with manual measurements when performing 3-dimensional surface measurements along a curved line (curvilinear). Dry mandibles (n = 61) with intact dentition were used. The mandibles were digitized using 2 chair-side intraoral scanners: Cadent iTero (Align Technology, San Jose, Calif) and Lythos Digital Impression system (Ormco, Orange, Calif). Digitized 3-dimensional models were converted to individual stereolithography files and used with commercial software to obtain the curvilinear measurements. Manual measurements were carried out directly on the mandibular teeth. Measurements were made on different locations on the dental arch in various directions. One-sample t tests and linear regression analyses were performed. To further graphically examine the accuracy between the different methods, Bland-Altman plots were computed. The level of significance was set at P 0.05). Bland-Altman analysis showed no fixed bias of 1 approach vs the other, and random errors were detected in all comparisons. Although the mean biases of the digital models obtained by the iTero and Lythos scanners, when compared with direct caliper measurements, were low, the comparison of the 2 intraoral scanners yielded the lowest mean bias. No comparison displayed statistical significance for the t scores; this indicated the absence of proportional bias in these comparisons. The intraoral scanners tested in this study produced digital dental models that were comparatively accurate when performing direct surface measurements along a curved line in 3 dimensions. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  4. Management of Subcondylar Fracture through Intraoral Approach with Rigid Internal Fixation.

    Science.gov (United States)

    Patil, Ravi S; Gudi, Santosh S

    2011-09-01

    In Oral and Maxillofacial Surgery, the majority of the condylar fractures are treated by closed reduction with generally satisfactory long term results. But in such cases of closed reduction, patient will be uncomfortable owing to long term application of inter maxillary fixation (IMF). Where as, Disadvantages of extra oral open reduction and fixation of condylar fracture includes facial nerve damage, facial scars etc. which are surely eliminated by the intraoral reduction and rigid fixation. The present study was conducted to determine the efficacy of reduction and fixation of low sub-condylar fractures through intra-oral approach. In this study, ten patients with low sub-condylar fracture, reported to department of Oral and Maxillofacial Surgery. P.M.N.M. Dental College and Hospital Bagalkot were included. These patients were treated by open reduction and internal fixation through intra-oral approach. All the patients were evaluated postoperatively for mouth opening, occlusion and mandibular deviation with regular radiographic examination for 6 weeks. All operated patients followed for 6 weeks, maximum mouth opening was more than 40 mm in seven patients (range from 40 to 50 mm) and less than 40 mm in three patients. Occlusion was satisfactory in all and none of the patients showed deviation of mandible on mouth opening. Statistical analysis showed that postoperative mouth opening was significant ('t' value = 7.88, 'P' = (0.000) value = 1.96, 'P' value (0.081), 0.05]. For occlusion standard photographs were obtained at sixth week and found minor occlusal corrections in two patients are treated by elastic traction for few days. Open reduction with internal fixation through intraoral approach has proved to be safe for early function and also effective by avoiding the patient discomfort due to long term intermaxillary fixation, psychological effect, facial nerve damage, facial scar and weight loss.

  5. Amitriptyline and intraoral devices for migraine prevention: a randomized comparative trial

    OpenAIRE

    Bruno, Marco A. D.; Krymchantowski, Abouch V.

    2018-01-01

    ABSTRACT Objectives: Nonpharmacological treatments, such as the Nociceptive Trigeminal Inhibition Tension Suppression System (NTI-tss), are approved for migraine prophylaxis. We aimed at evaluating the effectiveness of the NTI-tss and to compare its efficacy with amitriptyline and with a sham intraoral device in the preventive treatment of migraine. Methods: Consecutive patients with migraine were randomized to receive 25 mg of amitriptyline/day (n = 34), NTI-tss (n = 33) and a non-occlusal...

  6. In vivo and in vitro assessment of an intraoral dental colorimeter.

    Science.gov (United States)

    Karaagaclioglu, Lale; Terzioglu, Hakan; Yilmaz, Burak; Yurdukoru, Bengul

    2010-06-01

    The purpose of this study was to assess the performance of an intraoral dental colorimeter. In vivo repeatability of an intraoral colorimeter was assessed by performing color measurements of 30 individuals' right maxillary central incisor. Three consecutive measurements from each individual were made. In the in vitro part of the study, 25 metal-ceramic and 25 all-ceramic specimens were prepared. Five shades of metal-ceramic and all-ceramic specimens were selected for color determination. A widely recognized in vitro colorimeter was used as the control group for the in vitro performance assessment of the in vivo colorimeter. The color differentiation capability of two colorimeters was compared with the readings obtained from ceramic specimens. DeltaE values between shade groups of ceramic specimens were calculated and statistically analyzed with Student's t-test. The repeatability of the intraoral instrument was evaluated statistically with Intraclass correlation coefficient. The in vivo evaluation results showed that the overall repeatability coefficient values of L*, a*, and b* notations of the intraoral colorimeter were "excellent." The color differences (DeltaE) calculated between the colorimeters were significant only between shades A(1)-B(1) for metal-ceramic specimens (p= 0.002); however, from 5 of 10 shade couples of all-ceramic specimens, the color differences obtained from the readings of the in vivo colorimeter were significantly different from that of the in vitro colorimeter (p colorimeter exhibited successful in vivo repeatability; however, the color difference detection performance of the device varied depending on the translucency of the specimens.

  7. ARTROPLASTIA DE LA ARTICULACIÓN TEMPORO-MANDIBULAR Y EMPLEO DEL ACTIVADOR INTRAORAL.

    OpenAIRE

    Merino Martijena, Adolfo

    2014-01-01

    Sixty Clinic Quirurgical Cases were Diagnostic with Anquilosis by the Pre Articular (Arthoplastic) Technique Using the Intra-Oral Activator design by the Author of this research the results were satisfactory in the one hundred per-cent of the treated cases.This Technique has the advantage of being very confortable don't cause pain is of casy manipulation and health in the rehabilitation process allowing the masticate recuperation and the mandible movements. Fueron efectuados 60 casos clíni...

  8. Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients.

    Science.gov (United States)

    Boeddinghaus, Moritz; Breloer, Eva Sabina; Rehmann, Peter; Wöstmann, Bernd

    2015-11-01

    The purpose of this clinical study was to compare the marginal fit of dental crowns based on three different intraoral digital and one conventional impression methods. Forty-nine teeth of altogether 24 patients were prepared to be treated with full-coverage restorations. Digital impressions were made using three intraoral scanners: Sirona CEREC AC Omnicam (OCam), Heraeus Cara TRIOS and 3M Lava True Definition (TDef). Furthermore, a gypsum model based on a conventional impression (EXA'lence, GC, Tokyo, Japan) was scanned with a standard laboratory scanner (3Shape D700). Based on the dataset obtained, four zirconia copings per tooth were produced. The marginal fit of the copings in the patient's mouth was assessed employing a replica technique. Overall, seven measurement copings did not fit and, therefore, could not be assessed. The marginal gap was 88 μm (68-136 μm) [median/interquartile range] for the TDef, 112 μm (94-149 μm) for the Cara TRIOS, 113 μm (81-157 μm) for the laboratory scanner and 149 μm (114-218 μm) for the OCam. There was a statistically significant difference between the OCam and the other groups (p < 0.05). Within the limitations of this study, it can be concluded that zirconia copings based on intraoral scans and a laboratory scans of a conventional model are comparable to one another with regard to their marginal fit. Regarding the results of this study, the digital intraoral impression can be considered as an alternative to a conventional impression with a consecutive digital workflow when the finish line is clearly visible and it is possible to keep it dry.

  9. An analysis of the physiologic parameters of intraoral wear: a review

    International Nuclear Information System (INIS)

    Lawson, Nathaniel C; Cakir, Deniz; Burgess, John O; Janyavula, Sridhar

    2013-01-01

    This paper reviews the conditions of in vivo mastication and describes a novel method of measuring in vitro wear. Methods: parameters of intraoral wear are reviewed in this analysis, including chewing force, tooth sliding distance, food abrasivity, saliva lubrication, and antagonist properties. Results: clinical measurement of mastication forces indicates a range of normal forces between 20 and 140 N for a single molar. During the sliding phase of mastication, horizontal movement has been measured between 0.9 and 2.86 mm. In vivo wear occurs by three-body abrasion when food particles are interposed between teeth and by two-body abrasion after food clearance. Analysis of food particles used in wear testing reveals that food particles are softer than enamel and large enough to separate enamel and restoration surfaces and act as a solid lubricant. In two-body wear, saliva acts as a boundary lubricant with a viscosity of 3 cP. Enamel is the most relevant antagonist material for wear testing. The shape of a palatal cusp has been estimated as a 0.6 mm diameter ball and the hardest region of a tooth is its enamel surface. pH values and temperatures have been shown to range between 2–7 and 5–55 °C in intraoral fluids, respectively. These intraoral parameters have been used to modify the Alabama wear testing method. (paper)

  10. Comparison of Adaptation between the Major Connectors Fabricated from Intraoral Digital Impressions and Extraoral Digital Impressions.

    Science.gov (United States)

    Gan, Ning; Ruan, Yaye; Sun, Jian; Xiong, Yaoyang; Jiao, Ting

    2018-01-11

    The objective was to compare the adaptation between the major connectors of removable partial dentures derived from intraoral digital impressions and extraoral digital impressions. Twenty-four volunteers were enrolled. Each volunteer received an intraoral digital impression and one extraoral digital impression digitized from conventional gypsum impression. A software was used to create the major connectors on digital impression datasets. After all the virtual major connectors designed from Group intraoral digital impressions (Group I) and Group extraoral digital impressions (Group E) were directly fabricated by 3D printing technique, the adaptation of the final major connectors in volunteers' mouths were measured. The adaptation ranged from 159.87 to 577.99 μm in Group I while from 120.83 to 536.17 μm in Group E. The adaptation of major connectors in Group I were found better at the midline palatine suture while the adaptation of major connectors in Group E were found better at the two sides of the palatal vault. In both groups, the highest accuracy in adaptation was revealed at the anterior margin of the major connectors. It is feasible to manufacture the major connectors by digital impression and 3D printing technique. Both the adaptation of the two kinds of digital impressions were clinical acceptable.

  11. Evaluation and clinical use of an intraoral inferior alveolar nerve block in the horse.

    Science.gov (United States)

    Henry, T; Pusterla, N; Guedes, A G P; Verstraete, F J M

    2014-11-01

    Local anaesthesia is often required to facilitate invasive procedures in equine dental patients under standing sedation. To show that an intraoral approach can be used to desensitise the inferior alveolar nerve in horses and report complications seen with this technique. The distance of the mandibular foramen from the distal (caudal) edge of the mandibular third molar tooth, rostral edge of the mandibular ramus and ventral margin of the mandible were measured in 26 adult equine skulls of various ages and breeds. Computed tomography (CT) was used to verify the placement of the local anaesthetic with a custom-made device on 4 equine cadaver heads. The technique was applied in 43 clinical cases having procedures performed on the mandibular quadrants using the delivery device. Computed tomography demonstrated that the intraoral approach provided deposition of the local anaesthetic at the mandibular foramen and anatomical localisation of mandibular foramen indicated that anaesthetic solution could be delivered with a 38 mm needle. Clinical patients to lerated invasive dental procedures following the inferior alveolar nerve block with a 5 ml dose of local anaesthetic, without evidence of self-inflicted lingual trauma. The inferior alveolar nerve was successfully desensitised with the intraoral approach with minimal complications. The reduced volume of local anaesthetic and ability to deposit the local anaesthetic in close proximity to the nerve compared with an extraoral technique may decrease the complication of self-inflicted lingual trauma. © 2013 EVJ Ltd.

  12. Intraoral corrosion of self-ligating metallic brackets and archwires and the effect on friction

    Science.gov (United States)

    Tima, Lori Lynn

    The purpose of this study was to investigate how the frictional coefficient was affected due to intraoral use. A secondary aim of this study was to determine whether or not there was a relationship between corrosion of orthodontic alloys and friction via scanning electron microscopic qualitative analysis. Orthodontic brackets and 0.019 x 0.025 inch stainless steel archwires were collected and divided into three groups of n=10: used bracket and used wires (UBUW), used brackets and new wires (UBNW), and new brackets and new wires (NBNW). New materials were as-received from the manufacturer, and used materials were clinically used bracket and wires collected from patients following orthodontic treatment. Archwires were pulled through bracket slots at a rate of 0.5mm/min while friction forces were measured. Following a cleaning process, the surface topography of the bracket slots was examined under a scanning electron microscope (SEM). Based on a 1-factor MANOVA, there was no significant group effect (all p>0.05) on frictional forces. Partial eta squared values indicated that intraoral exposure had only a small effect on frictional forces (≤ 3%). Qualitative analysis of SEM images did not show an association between surface characteristics of the bracket slots and magnitude of frictional force. Results suggest that surface corrosion from intraoral use does not significantly affect friction at the bracket wire interface.

  13. Bilateral Endoscopic Medial Maxillectomy for Bilateral Inverted Papilloma

    Directory of Open Access Journals (Sweden)

    Satoru Kodama

    2012-01-01

    Full Text Available Inverted papilloma (IP is a benign tumor of the nasal cavity and paranasal sinuses that is unilateral in most cases. Bilateral IP, involving both sides of the nasal cavity and sinuses, is extremely rare. This paper describes a large IP that filled in both sides of the nasal cavity and sinuses, mimicking association with malignancy. The tumor was successfully treated by bilateral endoscopic medial maxillectomy (EMM. The patient is without evidence of the disease 24 months after surgery. If preoperative diagnosis does not confirm the association with malignancy in IP, endoscopic sinus surgery (ESS should be selected, and ESS, including EMM, is a good first choice of the treatment for IP.

  14. A miniature X-ray tube based on carbon nanotube for an intraoral dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jin; Park, Han Beom; Lee, Ju Hyuk; Cho, Sung Oh [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    The number of human teeth that can be radiographically taken is limited. Moreover, at least two X-ray shots are required to get images of teeth from both sides of the mouth. In order to overcome the disadvantages of conventional dental radiography, a dental radiograph has been proposed in which an X-ray tube is inserted into the mouth while an X-ray detector is placed outside the mouth. The miniature X-ray tube is required small size to insert into the mouth. Recently, we have fabricated a miniature x-ray tube with the diameter of 7 mm using a carbon nanotube (CNT) field. But, commercialized miniature X-ray tube were adopted a thermionic type using tungsten filament. The X-ray tubes adopted thermionic emission has a disadvantage of increasing temperature of x-ray tube. So it need to cooling system to cool x-ray tube. On the other hands, X-ray tubes adopted CNT field emitters don't need cooling systems because electrons are emitted from CNT by applying high voltage without heating. We have developed the miniature x-ray tube that produce x-ray with uniform spatial distribution based on carbon nanotube field emitters. The fabricated miniature x-ray tube can be stably and reliably operated at 50kV without any vacuum pump. The developed miniature X-ray tube was applied for intraoral dental radiography that employs an intra-oral CNT-based miniature X-ray tube and extra-oral X-ray detectors. An X-ray image of many teeth was successfully obtained by a single X-ray shot using the intra-oral miniature X-ray tube system. Furthermore, images of both molar teeth of pig were simultaneously obtained by a single X-ray shot. These results show that the intraoral dental radiography, which employs an intraoral miniature X-ray tube and an extraoral X-ray detector, performs better than conventional dental radiography.

  15. A miniature X-ray tube based on carbon nanotube for an intraoral dental radiography

    International Nuclear Information System (INIS)

    Kim, Hyun Jin; Park, Han Beom; Lee, Ju Hyuk; Cho, Sung Oh

    2016-01-01

    The number of human teeth that can be radiographically taken is limited. Moreover, at least two X-ray shots are required to get images of teeth from both sides of the mouth. In order to overcome the disadvantages of conventional dental radiography, a dental radiograph has been proposed in which an X-ray tube is inserted into the mouth while an X-ray detector is placed outside the mouth. The miniature X-ray tube is required small size to insert into the mouth. Recently, we have fabricated a miniature x-ray tube with the diameter of 7 mm using a carbon nanotube (CNT) field. But, commercialized miniature X-ray tube were adopted a thermionic type using tungsten filament. The X-ray tubes adopted thermionic emission has a disadvantage of increasing temperature of x-ray tube. So it need to cooling system to cool x-ray tube. On the other hands, X-ray tubes adopted CNT field emitters don't need cooling systems because electrons are emitted from CNT by applying high voltage without heating. We have developed the miniature x-ray tube that produce x-ray with uniform spatial distribution based on carbon nanotube field emitters. The fabricated miniature x-ray tube can be stably and reliably operated at 50kV without any vacuum pump. The developed miniature X-ray tube was applied for intraoral dental radiography that employs an intra-oral CNT-based miniature X-ray tube and extra-oral X-ray detectors. An X-ray image of many teeth was successfully obtained by a single X-ray shot using the intra-oral miniature X-ray tube system. Furthermore, images of both molar teeth of pig were simultaneously obtained by a single X-ray shot. These results show that the intraoral dental radiography, which employs an intraoral miniature X-ray tube and an extraoral X-ray detector, performs better than conventional dental radiography

  16. Evaluation of OK-432 Injection Therapy as Possible Primary Treatment of Intraoral Ranula.

    Science.gov (United States)

    Kono, Michihide; Satomi, Takafumi; Abukawa, Harutsugi; Hasegawa, On; Watanabe, Masato; Chikazu, Daichi

    2017-02-01

    A ranula is a pseudocyst caused by mucous extravasation from the sublingual gland. Recently, a sclerosing agent, OK-432 (picibanil), has been reported to be highly effective for treating lymphangioma and cervical cystic lesions. The present study assessed the effectiveness of OK-432 injection therapy for intraoral ranula to clarify whether it can be used as the primary treatment. The present study was a retrospective clinical study of patients with intraoral ranula who received OK-432 injection therapy from 2005 to 2015. The ranula size was measured on computed tomography or magnetic resonance imaging studies. We dissolved 1 Klinische Einheit (KE) unit of OK-432 powder in normal saline equal to the aspiration volume. The primary endpoint was the treatment results. The secondary endpoints were the relation between the treatment results and the lesion length and aspiration volume. A total of 23 patients received OK-432 injection therapy for an intraoral ranula. The mean lesion size was 19.96 mm. The mean aspiration volume was 2.14 mL. The number of injections was 1 to 4 (mean 1.70). The treatment results were complete regression (CR) in 18 (78.2%), partial regression (PR) in 3 (13.0%), and no response (NR) in 2 (8%) patients after the last injection. The overall efficacy rate was 91.2% (21 of 23). No serious complications were observed. The lesion length and aspiration volume of the CR group was 17.38 mm and 1.40 mL, respectively. The lesion length and aspiration volume of the PR/NR group was 29.20 mm and 4.80 mL, respectively. The PR/NR group lesions were significantly larger than the CR group lesions. OK-432 injection therapy for intraoral ranula is safe and effective compared with other surgical therapies. This therapy could potentially become a primary treatment of intraoral ranula. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Bilateral pallidotomy for generalized dystonia Palidotomia bilateral para distonias generalizadas

    Directory of Open Access Journals (Sweden)

    Hélio A. G. Teive

    2001-06-01

    Full Text Available OBJECTIVE: To evaluate the efficacy and safety of bilateral pallidotomies in five patients with generalized dystonia. BACKGROUND: Generalized dystonias are frequently a therapeutic challenge, with poor responses to pharmacological treatment. GPi (globus pallidus internus pallidotomies for Parkinson's disease ameliorate all kinds of dyskinesias/dystonia, and recent studies reported a marked improvement of refractory dystonias with this procedure. METHODS: Five patients with generalized dystonias refractory to medical treatment were selected; one posttraumatic and four idiopathic. The decision to perform bilateral procedures was based on the predominant axial involvement in these patients. Dystonia severity was assessed with the Burke-Fahn-Marsden Dystonia Scale (BFM. Simultaneous procedures were performed in all but one patient, who had a staged procedure. They were reevaluated with the same scale (BFM by an unblinded rater at 1, 2, 3, 30, 60, 90, 120 and 180 days post-operatively. RESULTS: The four patients with idiopathic dystonia showed a progressive improvement up to three months; the patient with posttraumatic dystonia relapsed at three months. One patient had a marked improvement, being able to discontinue all the medications. A mean decrease in the BFM scores of 52,58% was noted. One patient had a trans-operative motor seizure followed by a transient hemiparesis secondary to rack hemorrhage; other was lethargic up to three days after the procedure. CONCLUSIONS: Our results show that bilateral GPi pallidotomies may be a safe and effective approach to medically refractory generalized dystonias; it can also be speculated that the posttraumatic subgroup may not benefit with this procedure.As distonias generalizadas são freqüentemente um desafio terapêutico, com pobres respostas aos tratamentos farmacológicos. As cirurgias estereotáxicas, como a palidotomia, têm sido utilizadas com êxito no tratamento da doença de Parkinson e estudos

  18. Immediate Sequential Bilateral Cataract Surgery

    DEFF Research Database (Denmark)

    Kessel, Line; Andresen, Jens; Erngaard, Ditte

    2015-01-01

    The aim of the present systematic review was to examine the benefits and harms associated with immediate sequential bilateral cataract surgery (ISBCS) with specific emphasis on the rate of complications, postoperative anisometropia, and subjective visual function in order to formulate evidence......-based national Danish guidelines for cataract surgery. A systematic literature review in PubMed, Embase, and Cochrane central databases identified three randomized controlled trials that compared outcome in patients randomized to ISBCS or bilateral cataract surgery on two different dates. Meta-analyses were...... performed using the Cochrane Review Manager software. The quality of the evidence was assessed using the GRADE method (Grading of Recommendation, Assessment, Development, and Evaluation). We did not find any difference in the risk of complications or visual outcome in patients randomized to ISBCS or surgery...

  19. BILATERAL DUPLICATION OF RENAL ARTERIES

    OpenAIRE

    Prajkta A Thete; Mehera Bhoir; M.V.Ambiye

    2014-01-01

    Routine dissection of a male cadaver revealed the presence of bilateral double renal arteries. On the right side the accessory renal artery originated from the abdominal aorta just above the main renal artery. On the left side the accessory renal artery originated from the abdominal aorta about 1 cm above the main renal artery. Knowledge of the variations of renal vascular anatomy has importance in exploration and treatment of renal trauma, renal transplantation, renal artery embolization, su...

  20. China's Bilateral Currency Swap Lines

    OpenAIRE

    Zhitao, Lin; Wenjie, Zhan; Cheung, Yin-Wong

    2016-01-01

    We study the determinants of China’s bilateral local currency swap lines that were established since the recent global finance crisis. It is found that economic factors, political considerations, and institutional characteristics including trade intensity, economic size, strategic partnership, free trade agreement, corruption, and stability affect the decision of signing a swap line agreement. Once a swap line agreement decision is made, the size of the swap line is then mainly affected by tr...

  1. Simultaneous and staged bilateral total hip arthroplasty

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Joergensen, Christoffer Calov; Husted, Henrik

    2013-01-01

    Bilateral total hip arthroplasty (BTHA) and bilateral simultaneous total hip arthroplasty (BSTHA) are done increasingly. Previous studies evaluating outcomes after bilateral procedures have found different results. The aim of this study was to investigate length of hospital stay (LOS), 30 days...

  2. BILATERAL SINGLE SESSION URETEROSCOPY FOR URETERAL ...

    African Journals Online (AJOL)

    Objectives: To determine the feasibility, safety and success rate of bilateral single session rigid retrograde ureteroscopy (URS) for bilateral ureteral calculi. Patients and Methods: Thirty-five patients underwent bilateral single session ureteroscopic calculus removal. Results: Out of 70 renal units in 35 patients treated, ...

  3. Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.

    Science.gov (United States)

    Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan

    2011-01-01

    With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Assessing the effectiveness of massage therapy for bilateral cleft lip reconstruction scars.

    Science.gov (United States)

    McKay, Emilie

    2014-06-01

    Bilateral cleft lips occur when the bones that form the upper lip fail to fuse at birth. Surgical reconstruction creates scars, which may lead to the following impairments: adhesions, decreased oral range of motion, decreased strength of orbicularis oris muscle, and asymmetry of oral region leading to poor self-esteem. The purpose of this case study is to determine the effectiveness of massage therapy in its ability to improve these impairments. A five-week treatment plan consisting of fascial release, kneading, and intraoral techniques. Subjective information was assessed on two scales: restriction of scar and clients attitudes and acceptance of scar. Objective information was cataloged through photographs, a palpatory chart, and a self-created "Pen Test". Results included increase range of motion and strength, decrease restrictions (palpable and subjective), and increase of symmetry. Client's perceived confidence of scar and its appearance increased. The evidence suggests that massage therapy helped with the impairments associated with scars formed by bilateral cleft lip reconstruction.

  5. Hydraulic bilateral construction robot; Yuatsushiki bilateral kensetsu robot

    Energy Technology Data Exchange (ETDEWEB)

    Maehata, K.; Mori, N. [Kayaba Industry Co. Ltd., Tokyo (Japan)

    1999-05-15

    Concerning a hydraulic bilateral construction robot, its system constitution, structures and functions of important components, and the results of some tests are explained, and the researches conducted at Gifu University are described. The construction robot in this report is a servo controlled system of a version developed from the mini-shovel now available in the market. It is equipped, in addition to an electrohydraulic servo control system, with various sensors for detecting the robot attitude, vibration, and load state, and with a camera for visualizing the surrounding landscape. It is also provided with a bilateral joy stick which is a remote control actuator capable of working sensation feedback and with a rocking unit that creates robot movements of rolling, pitching, and heaving. The construction robot discussed here, with output increased and response faster thanks to the employment of a hydraulic driving system for the aim of building a robot system superior in performance to the conventional model designed primarily for heavy duty, proves after tests to be a highly sophisticated remotely controlled robot control system. (NEDO)

  6. Bilateral cleft lip nasal deformity

    Directory of Open Access Journals (Sweden)

    Singh Arun

    2009-01-01

    Full Text Available Bilateral cleft lip nose deformity is a multi-factorial and complex deformity which tends to aggravate with growth of the child, if not attended surgically. The goals of primary bilateral cleft lip nose surgery are, closure of the nasal floor and sill, lengthening of the columella, repositioning of the alar base, achieving nasal tip projection, repositioning of the lower lateral cartilages, and reorienting the nares from horizontal to oblique position. The multiplicity of procedures in the literature for correction of this deformity alludes to the fact that no single procedure is entirely effective. The timing for surgical intervention and its extent varies considerably. Early surgery on cartilage may adversely affect growth and development; at the same time, allowing the cartilage to grow in an abnormal position and contributing to aggravation of deformity. Some surgeons advocate correction of deformity at an early age. However, others like the cartilages to grow and mature before going in for surgery. With peer pressure also becoming an important consideration during the teens, the current trend is towards early intervention. There is no unanimity in the extent of nasal dissection to be done at the time of primary lip repair. While many perform limited nasal dissection for the fear of growth retardation, others opt for full cartilage correction at the time of primary surgery itself. The value of naso-alveolar moulding (NAM too is not universally accepted and has now more opponents than proponents. Also most centres in the developing world have neither the personnel nor the facilities for the same. The secondary cleft nasal deformity is variable and is affected by the extent of the original abnormality, any prior surgeries performed and alteration due to nasal growth. This article reviews the currently popular methods for correction of nasal deformity associated with bilateral cleft lip, it′s management both at the time of cleft lip repair

  7. Intraoral versus extraoral measurement of the height of the interproximal contact area in maxillary anterior teeth.

    Science.gov (United States)

    Sghaireen, Mohd G; Albhiran, Heyam Mobark; Alzoubi, Ibrahim A; Lynch, Edward; Al-Omiri, Mahmoud K

    2015-01-01

    This study aimed to clinically quantify the apicoincisal height of the upper interproximal areas directly in patients' mouths compared to measurements on stone models. One hundred and fifty participants (75 females and 75 males, age range 20-45 years) were recruited for this study. A digital caliper was used to measure the anterior maxillary interproximal contact areas directly in patients' mouths and on stone models. The digital caliper accuracy was up to 0.01. The Statistical Package for Social Sciences software (SPSS, version 19.0, Chicago, Ill., USA) was used for statistical analysis. Statistical significance was based on probability values contacts as well as the measurement on stone models showed that the dimensions of interproximal contacts on both sides of each tooth were significantly different (p contact point was larger than that of the distal contact point of each tooth. The largest contact point was the one between the central incisors (direct intraoral measurement = 2.9-6.49 mm; model measurement = 3.31-6.91 mm). On the other hand, the contact point between the canine and first premolar was the smallest on both sides of the arch (0.63-2.52 mm intraorally, 0.98-2.88 mm on models). The intraoral measurement of contact points was more accurate than model measurements, and the differences were statistically significant (p contact point dimensions using a digital caliper was more precise than measuring contact points on stone models; hence, it is a viable, quick and adequate method to be used routinely. © 2015 S. Karger AG, Basel.

  8. Quantitative analysis of alveolar bone change following implant placement using intraoral radiographic subtraction

    International Nuclear Information System (INIS)

    Kimura, Hiroyuki; Kanda, Shigenobu; Tanaka, Takemasa

    2002-01-01

    The purpose of this study was to develop a procedure for quantitative analysis using intraoral radiographs of alveolar bone after placement of dental implants and to consider the validity of the method. We evaluated the ten patients (2 males and 8 females, average age: 48.4 years-old), who were treated with dental implant operation in the site of mandibular molar region, since October of 1999 until September of 2000 in Kimura Dental Clinic (Kumamoto, Japan). We evaluated the intraoral radiographs taken pre- and post- operatively and at follow-up examination. To detect alveolar bone change on radiograph, we adopted the digital subtraction method. Although the radiographs were taken under an ordinary technique with cone indicator, we did not apply the standardized technique with fixing material customized for each patient. Therefore, we used geometric correction and density compensation before subtraction. We assessed the basic statistical values (mean, variance, kurtosis and skewness) of the region of interest (ROI) of the subtracted images. Also, we noted PPD (probing pocket depth) and BOP (bleeding on probing) at each site as indicators of clinical findings and all implanted sites were classified according to the PPD or BOP, i.e. PPD increased group ''PPD (+)'' and PPD stable group ''PPD (-)'', likewise BOP positive group ''BOP (+)'' and negative group ''BOP (-)''. We considered the statistical values of ROI in each group and compared these findings. Mean and variance values of PPD (+) were higher than those of PPD (-) and there was a significant difference in mean value (p=0.031). Similarly, mean and variance values of BOP (+) were statistically higher than those of BOP (-) (p=0.041 and p=0.0087, respectively). Concerning kurtosis and skewness, there was no difference between PPD (+) and PPD (-), or between BOP (+) and BOP (-). Using our method, the radiographs taken for follow-up examination could be assessed quantitatively. It is suggested that geometric

  9. Evaluation of radiation dose to patients in intraoral dental radiography using Monte Carlo Method

    International Nuclear Information System (INIS)

    Park, Il; Kim, Kyeong Ho; Oh, Seung Chul; Song, Ji Young

    2016-01-01

    The use of dental radiographic examinations is common although radiation dose resulting from the dental radiography is relatively small. Therefore, it is required to evaluate radiation dose from the dental radiography for radiation safety purpose. The objectives of the present study were to develop dosimetry method for intraoral dental radiography using a Monte Carlo method based radiation transport code and to calculate organ doses and effective doses of patients from different types of intraoral radiographies. Radiological properties of dental radiography equipment were characterized for the evaluation of patient radiation dose. The properties including x-ray energy spectrum were simulated using MCNP code. Organ doses and effective doses to patients were calculated by MCNP simulation with computational adult phantoms. At the typical equipment settings (60 kVp, 7 mA, and 0.12 sec), the entrance air kerma was 1.79 mGy and the measured half value layer was 1.82 mm. The half value layer calculated by MCNP simulation was well agreed with the measurement values. Effective doses from intraoral radiographies ranged from 1 μSv for maxilla premolar to 3 μSv for maxilla incisor. Oral cavity layer (23⁓82 μSv) and salivary glands (10⁓68 μSv) received relatively high radiation dose. Thyroid also received high radiation dose (3⁓47 μSv) for examinations. The developed dosimetry method and evaluated radiation doses in this study can be utilized for policy making, patient dose management, and development of low-dose equipment. In addition, this study can ultimately contribute to decrease radiation dose to patients for radiation safety

  10. Evaluation of radiation dose to patients in intraoral dental radiography using Monte Carlo Method

    Energy Technology Data Exchange (ETDEWEB)

    Park, Il; Kim, Kyeong Ho; Oh, Seung Chul; Song, Ji Young [Dept. of Nuclear Engineering, Kyung Hee University, Yongin (Korea, Republic of)

    2016-11-15

    The use of dental radiographic examinations is common although radiation dose resulting from the dental radiography is relatively small. Therefore, it is required to evaluate radiation dose from the dental radiography for radiation safety purpose. The objectives of the present study were to develop dosimetry method for intraoral dental radiography using a Monte Carlo method based radiation transport code and to calculate organ doses and effective doses of patients from different types of intraoral radiographies. Radiological properties of dental radiography equipment were characterized for the evaluation of patient radiation dose. The properties including x-ray energy spectrum were simulated using MCNP code. Organ doses and effective doses to patients were calculated by MCNP simulation with computational adult phantoms. At the typical equipment settings (60 kVp, 7 mA, and 0.12 sec), the entrance air kerma was 1.79 mGy and the measured half value layer was 1.82 mm. The half value layer calculated by MCNP simulation was well agreed with the measurement values. Effective doses from intraoral radiographies ranged from 1 μSv for maxilla premolar to 3 μSv for maxilla incisor. Oral cavity layer (23⁓82 μSv) and salivary glands (10⁓68 μSv) received relatively high radiation dose. Thyroid also received high radiation dose (3⁓47 μSv) for examinations. The developed dosimetry method and evaluated radiation doses in this study can be utilized for policy making, patient dose management, and development of low-dose equipment. In addition, this study can ultimately contribute to decrease radiation dose to patients for radiation safety.

  11. Application of intra-oral dental scanners in the digital workflow of implantology.

    Directory of Open Access Journals (Sweden)

    Wicher J van der Meer

    Full Text Available Intra-oral scanners will play a central role in digital dentistry in the near future. In this study the accuracy of three intra-oral scanners was compared.A master model made of stone was fitted with three high precision manufactured PEEK cylinders and scanned with three intra-oral scanners: the CEREC (Sirona, the iTero (Cadent and the Lava COS (3M. In software the digital files were imported and the distance between the centres of the cylinders and the angulation between the cylinders was assessed. These values were compared to the measurements made on a high accuracy 3D scan of the master model.The distance errors were the smallest and most consistent for the Lava COS. The distance errors for the Cerec were the largest and least consistent. All the angulation errors were small.The Lava COS in combination with a high accuracy scanning protocol resulted in the smallest and most consistent errors of all three scanners tested when considering mean distance errors in full arch impressions both in absolute values and in consistency for both measured distances. For the mean angulation errors, the Lava COS had the smallest errors between cylinders 1-2 and the largest errors between cylinders 1-3, although the absolute difference with the smallest mean value (iTero was very small (0,0529°. An expected increase in distance and/or angular errors over the length of the arch due to an accumulation of registration errors of the patched 3D surfaces could be observed in this study design, but the effects were statistically not significant.For making impressions of implant cases for digital workflows, the most accurate scanner with the scanning protocol that will ensure the most accurate digital impression should be used. In our study model that was the Lava COS with the high accuracy scanning protocol.

  12. Surface changes of metal alloys and high-strength ceramics after ultrasonic scaling and intraoral polishing.

    Science.gov (United States)

    Yoon, Hyung-In; Noh, Hyo-Mi; Park, Eun-Jin

    2017-06-01

    This study was to evaluate the effect of repeated ultrasonic scaling and surface polishing with intraoral polishing kits on the surface roughness of three different restorative materials. A total of 15 identical discs were fabricated with three different materials. The ultrasonic scaling was conducted for 20 seconds on the test surfaces. Subsequently, a multi-step polishing with recommended intraoral polishing kit was performed for 30 seconds. The 3D profiler and scanning electron microscopy were used to investigate surface integrity before scaling (pristine), after scaling, and after surface polishing for each material. Non-parametric Friedman and Wilcoxon signed rank sum tests were employed to statistically evaluate surface roughness changes of the pristine, scaled, and polished specimens. The level of significance was set at 0.05. Surface roughness values before scaling (pristine), after scaling, and polishing of the metal alloys were 3.02±0.34 µm, 2.44±0.72 µm, and 3.49±0.72 µm, respectively. Surface roughness of lithium disilicate increased from 2.35±1.05 µm (pristine) to 28.54±9.64 µm (scaling), and further increased after polishing (56.66±9.12 µm, P scaling (from 1.65±0.42 µm to 101.37±18.75 µm), while its surface roughness decreased after polishing (29.57±18.86 µm, P scaling significantly changed the surface integrities of lithium disilicate and zirconia. Surface polishing with multi-step intraoral kit after repeated scaling was only effective for the zirconia, while it was not for lithium disilicate.

  13. Knowledge, Attitude and Performance of Shiraz General Dentists about Infection Control Principles during Preparing Intraoral Radiographies

    Directory of Open Access Journals (Sweden)

    Abdolaziz Hagh Negahdar

    2017-02-01

    Full Text Available Background & Objective: Infection control in dental centers is affected by the persons’ attitude and knowledge about mechanisms of infection transmission. This study was designed to evaluate the knowledge and the attitude of Shiraz dentists about infection control during intraoral radiographies preparation. Materials & Methods: In this cross-sectional, and analytical research, the attitude and the knowledge of 45 male and 25 female, randomly selected dentists, were obtained through completion of a researcher- planed questioner which its validity and reliability had been confirmed. Data were analyzed using Cronbach`s alpha, one-way ANOVA, student’s t-test, and Pearson’s correlation coefficient in SPSS (V.21. Results: The average of the dentists’ age was 40.59±10.72 and their average occupational experience was 13.49±9.75 years. The mean score obtained for knowledge about infection control during intraoral radiographic procedures was less than fifty percent of total obtainable score, and was assessed as weak knowledge. There was no significant difference in the level of knowledge between studied male and female dentists (P>0.05. In addition, no significant relationship was detected between level, age/experience, and the university of education (P>0.05. The attitude of the dentists about infection control during intraoral radiography preparation assessed as moderate to good level. Conclusions: The results showed that the main reason for the present problems is insufficient knowledge of the dentists in related subjects. Therefore, the solution, which is recommended among dentists, is to raise their awareness and to change their attitudes and culture in order to improve their performance.

  14. Establishment of local diagnostic reference levels for quality control in intraoral radiography.

    Science.gov (United States)

    Izawa, Maki; Harata, Yasuo; Shiba, Noriyoshi; Koizumi, Nobuhide; Ozawa, Tomonori; Takahashi, Nobutoshi; Okumura, Yasuhiko

    2017-01-01

    To investigate the dosage and imaging conditions for patients undergoing intraoral radiography at Meikai University Hospital and establish assurance and quality control data. Tube voltage, exposure time, and air kinetic energy released per unit mass (air kerma) of three intraoral radiography units were measured. To calculate the patient entrance dose (PED) for each radiograph using Insight film, we extracted data for 1063 patients from their exposure records. The PED was compared with the diagnostic reference level (DRL) from the European Commission and the UK. The tube voltage of the three units was maintained at 60 ± 2 kV. Differences in exposure time were less than 1.7 % for all units. The air kerma rates were well maintained within a 4.2 % error. Based on the patient data, there were no significant differences in the mean exposure times for males and females for all anatomical sites. The mean PED ranged from 1.09 ± 0.31 mGy for the mandibular incisors to 2.42 ± 0.33 mGy for the maxillary molars. The mean PED at the mandibular molars using InSight film was 1.59 ± 0.20 mGy, being less than the recommended value based on the DRL for intraoral radiography in the UK. We concluded that radiographic conditions at the hospital have been properly maintained. This basic quality control data may assist other dental radiation facilities to reduce patient dosage.

  15. Application of Intra-Oral Dental Scanners in the Digital Workflow of Implantology

    Science.gov (United States)

    van der Meer, Wicher J.; Andriessen, Frank S.; Wismeijer, Daniel; Ren, Yijin

    2012-01-01

    Intra-oral scanners will play a central role in digital dentistry in the near future. In this study the accuracy of three intra-oral scanners was compared. Materials and methods: A master model made of stone was fitted with three high precision manufactured PEEK cylinders and scanned with three intra-oral scanners: the CEREC (Sirona), the iTero (Cadent) and the Lava COS (3M). In software the digital files were imported and the distance between the centres of the cylinders and the angulation between the cylinders was assessed. These values were compared to the measurements made on a high accuracy 3D scan of the master model. Results: The distance errors were the smallest and most consistent for the Lava COS. The distance errors for the Cerec were the largest and least consistent. All the angulation errors were small. Conclusions: The Lava COS in combination with a high accuracy scanning protocol resulted in the smallest and most consistent errors of all three scanners tested when considering mean distance errors in full arch impressions both in absolute values and in consistency for both measured distances. For the mean angulation errors, the Lava COS had the smallest errors between cylinders 1–2 and the largest errors between cylinders 1–3, although the absolute difference with the smallest mean value (iTero) was very small (0,0529°). An expected increase in distance and/or angular errors over the length of the arch due to an accumulation of registration errors of the patched 3D surfaces could be observed in this study design, but the effects were statistically not significant. Clinical relevance For making impressions of implant cases for digital workflows, the most accurate scanner with the scanning protocol that will ensure the most accurate digital impression should be used. In our study model that was the Lava COS with the high accuracy scanning protocol. PMID:22937030

  16. Examination of the Position Accuracy of Implant Abutments Reproduced by Intra-Oral Optical Impression

    Science.gov (United States)

    Odaira, Chikayuki; Kobayashi, Takuya; Kondo, Hisatomo

    2016-01-01

    An impression technique called optical impression using intraoral scanner has attracted attention in digital dentistry. This study aimed to evaluate the accuracy of the optical impression, comparing a virtual model reproduced by an intraoral scanner to a working cast made by conventional silicone impression technique. Two implants were placed on a master model. Working casts made of plaster were fabricated from the master model by silicone impression. The distance between the ball abutments and the angulation between the healing abutments of 5 mm and 7 mm height at master model were measured using Computer Numerical Control Coordinate Measuring Machine (CNCCMM) as control. Working casts were then measured using CNCCMM, and virtual models via stereo lithography data of master model were measured by a three-dimensional analyzing software. The distance between ball abutments of the master model was 9634.9 ± 1.2 μm. The mean values of trueness of the Lava COS and working casts were 64.5 μm and 22.5 μm, respectively, greater than that of control. The mean of precision values of the Lava COS and working casts were 15.6 μm and 13.5 μm, respectively. In the case of a 5-mm-height healing abutment, mean angulation error of the Lava COS was greater than that of the working cast, resulting in significant differences in trueness and precision. However, in the case of a 7-mm-height abutment, mean angulation errors of the Lava COS and the working cast were not significantly different in trueness and precision. Therefore, distance errors of the optical impression were slightly greater than those of conventional impression. Moreover, the trueness and precision of angulation error could be improved in the optical impression using longer healing abutments. In the near future, the development of information technology could enable improvement in the accuracy of the optical impression with intraoral scanners. PMID:27706225

  17. Five years experience with a new intraoral maxillary distraction device (RID).

    Science.gov (United States)

    Picard, Arnaud; Diner, Patrick A; Galliani, Eva; Tomat, Catherine; Vazquez, Ma rie Paule; Carls, Friedrich P

    2011-10-01

    Maxillary distraction osteogenesis is well established for the treatment of severe retromaxilla. We report our experience since 2004 of the treatment of 19 patients using a new intraoral maxillary distraction device. Maxillary advancement was successful in all patients with mean advancement of 9.6mm (range 4-17) measured at a point in lateral cephalograms. The new device limited surgical exposure and the amount of materials implanted, and improved control in every phase of the distraction. It was psychologically accepted by patients and was more comfortable than existing devices. Copyright © 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Panoramic dental radiography with an intra-oral X-ray tube

    International Nuclear Information System (INIS)

    Hollender, L.

    1980-01-01

    Surveys of the complete dentition and jaws can be obtained in various ways. Panoramic radiography with an intra-oral X-ray tube results in a lower radiation exposure than other methods, and is less time-consuming. However, the symmetrical views generally employed result in relatively poor imaging of the molars. This disadvantage can be overcome by using lateral projections which also cause less discomfort for the patient and, particularly in combination with intensifying screens, a further reduction in radiation exposure. Some possible future trends are suggested. (Auth.)

  19. The optimum circular field size for dental radiography with intraoral films

    International Nuclear Information System (INIS)

    van Straaten, F.J.; van Aken, J.

    1982-01-01

    Intraoral radiographs are often made with circular fields to irradiate the film, and in many instances these fields are much larger than the film. The feasibility of reducing a circular radiation field without increasing the probability of excessive cone cutting was evaluated clinically, and an optimum field size was determined. A circular radiation field 4.5 cm. at the tube end was found to minimize cone cutting and reduce the area of tissue irradiated by at least 44 percent. Findings suggest that current I.C.R.P. recommendations for a 6 to 7.5 cm. diameter circular field may be too liberal

  20. Comparison of intra-oral and study cast measurements in the assessment of malocclusion.

    Science.gov (United States)

    Ovsenik, Maja; Farcnik, Franc M; Verdenik, Ivan

    2004-06-01

    Malocclusion assessment methods are based on registrations and measurements made on study casts, which requires that impressions be taken. In addition to being costly and time-consuming, this process can be unpleasant for very young children. Therefore, the aim of this study was to evaluate the reliability of intra-oral measurements that compute a malocclusion index score to determine malocclusion severity in the mixed dentition. The research was part of a longitudinal study in Slovenia on a sample of 530 3-year-old children. At 8 years of age (mean 8.5 years, standard deviation 0.2), a cohort of 101 children (44 boys, 57 girls) was randomly selected in a cross-sectional study. Quantitative registrations of space and occlusal anomalies were performed intra-orally as well as on study casts. Kappa (kappa) statistics were used to evaluate the agreement between clinical and study cast malocclusion assessments. Systematic bias of measurements was tested using Wilcoxon's signed rank test. The results showed complete agreement between the two measurements for anterior crossbite, anterior open bite and overjet scores (kappa = 1); excellent reliability for the buccal segment relationship (kappa = 0.93), transverse occlusion of posterior teeth (kappa = 0.87); and substantial agreement for overbite (kappa = 0.79) and midline deviation (kappa = 0.71). For the remainder of the traits the agreement was moderate: rotation of incisors (kappa = 0.58), crowding of upper incisors (kappa = 0.51), axial inclination of teeth (kappa = 0.44) and lower incisor crowding (kappa = 0.41). Intra-orally small, but statistically significant scoring of lower incisor rotation and crowding was identified. On the study casts the most favourable axial inclination was found for buccal segment occlusion. Overall classification into severity grades, based on the total malocclusion score, showed excellent agreement between the two methods (kappa = 0.89), without statistically significant bias

  1. Accuracy evaluation of intraoral optical impressions: A clinical study using a reference appliance.

    Science.gov (United States)

    Atieh, Mohammad A; Ritter, André V; Ko, Ching-Chang; Duqum, Ibrahim

    2017-09-01

    Trueness and precision are used to evaluate the accuracy of intraoral optical impressions. Although the in vivo precision of intraoral optical impressions has been reported, in vivo trueness has not been evaluated because of limitations in the available protocols. The purpose of this clinical study was to compare the accuracy (trueness and precision) of optical and conventional impressions by using a novel study design. Five study participants consented and were enrolled. For each participant, optical and conventional (vinylsiloxanether) impressions of a custom-made intraoral Co-Cr alloy reference appliance fitted to the mandibular arch were obtained by 1 operator. Three-dimensional (3D) digital models were created for stone casts obtained from the conventional impression group and for the reference appliances by using a validated high-accuracy reference scanner. For the optical impression group, 3D digital models were obtained directly from the intraoral scans. The total mean trueness of each impression system was calculated by averaging the mean absolute deviations of the impression replicates from their 3D reference model for each participant, followed by averaging the obtained values across all participants. The total mean precision for each impression system was calculated by averaging the mean absolute deviations between all the impression replicas for each participant (10 pairs), followed by averaging the obtained values across all participants. Data were analyzed using repeated measures ANOVA (α=.05), first to assess whether a systematic difference in trueness or precision of replicate impressions could be found among participants and second to assess whether the mean trueness and precision values differed between the 2 impression systems. Statistically significant differences were found between the 2 impression systems for both mean trueness (P=.010) and mean precision (P=.007). Conventional impressions had higher accuracy with a mean trueness of 17.0

  2. Densitometric evaluation of intraoral x-ray films: Ektaspeed versus Ultraspeed

    International Nuclear Information System (INIS)

    Kaffe, I.; Littner, M.M.; Kuspet, M.E.

    1984-01-01

    Recently a new speed E intraoral dental x-ray film was introduced by the Eastman Kodak Company in order to reduce the radiation dose to the patient. In the present study the new higher-speed EP21 film was compared with the speed D DF58 film with regard to speed and quality (fog plus base, sharpness, resolution, and contrast) of the resulting images. Results showed no deterioration in the image with 50% dose reduction when the EP21 film was used as compared to the DF58 film. Therefore, this new type of film is highly recommended for routine radiographic examinations

  3. The Soft Seal disposable laryngeal mask airway in adults: comparison of two insertion techniques without intra-oral manipulation.

    Science.gov (United States)

    Kuvaki, B; Küçükgüçlü, S; Iyilikçi, L; Tuncali, B E; Cinar, O

    2008-10-01

    We investigated whether insertion of the disposable Soft Seal laryngeal mask airway (SSLM) was successful without intra-oral digital manipulation. One hundred patients undergoing anaesthesia using the SSLM were randomly assigned into two groups. Insertion was performed by either a direct or a rotational technique, both without intra-oral digital manipulation. The primary outcome measure was successful insertion at first attempt. Other outcomes included insertion time, fibreoptic assessment of the airway view and airway morbidity. The first attempt success rate was higher (98%) with the direct technique than with the rotational technique (75%; p = 0.002) but insertion time was faster with the latter method (mean [range] 15 [8-50] s) than with the direct method (20 [8-56] s; p = 0.035). Fibreoptic assessment and airway morbidity were similar in both groups. We conclude that the SSLM can be successfully inserted without intra-oral digital manipulation.

  4. Continuous measurement of intra-oral pH and temperature: development, validation of an appliance and a pilot study.

    Science.gov (United States)

    Choi, J E; Loke, C; Waddell, J N; Lyons, K M; Kieser, J A; Farella, M

    2015-08-01

    To describe a novel approach for continuous measurement of intra-oral pH and temperature in individuals carrying out normal daily activities over 24 h. We designed, validated and constructed a custom-made appliance fitted with a pH probe and a thermocouple. Six subjects wore the appliance over a 24-h period for two non-consecutive days, while the intra-oral pH and temperature were measured continuously and recorded. Intra-oral pH and temperature were very similar across different recording days, the difference being not statistically significant (P ≥ 0.14). There was a noticeable difference in the pattern of variation of pH between day and night. During the day, the mean pH was 7.3 (±0.4) and dropped markedly only after consumption of acidic food and drinks. The intra-oral pH decreased slowly during sleep with an average pH of 6.6 (±0.4) being recorded. The difference between day and night was statistically significant (P = 0.002). The mean intra-oral temperature was 33.9 °C (±0.9) during daytime and 35·9 °C (±0·5) during sleep (P = 0.013) with minor fluctuations occurring over 24 h. The continuous and simultaneous intra-oral pH and temperature measurement system described in this report is reliable, easy to construct, able to measure variables over a sustained period and may serve as a future diagnostic tool in a number of applications. © 2015 John Wiley & Sons Ltd.

  5. Accuracy of complete-arch model using an intraoral video scanner: An in vitro study.

    Science.gov (United States)

    Jeong, Il-Do; Lee, Jae-Jun; Jeon, Jin-Hun; Kim, Ji-Hwan; Kim, Hae-Young; Kim, Woong-Chul

    2016-06-01

    Information on the accuracy of intraoral video scanners for long-span areas is limited. The purpose of this in vitro study was to evaluate and compare the trueness and precision of an intraoral video scanner, an intraoral still image scanner, and a blue-light scanner for the production of digital impressions. Reference scan data were obtained by scanning a complete-arch model. An identical model was scanned 8 times using an intraoral video scanner (CEREC Omnicam; Sirona) and an intraoral still image scanner (CEREC Bluecam; Sirona), and stone casts made from conventional impressions of the same model were scanned 8 times with a blue-light scanner as a control (Identica Blue; Medit). Accuracy consists of trueness (the extent to which the scan data differ from the reference scan) and precision (the similarity of the data from multiple scans). To evaluate precision, 8 scans were superimposed using 3-dimensional analysis software; the reference scan data were then superimposed to determine the trueness. Differences were analyzed using 1-way ANOVA and post hoc Tukey HSD tests (α=.05). Trueness in the video scanner group was not significantly different from that in the control group. However, the video scanner group showed significantly lower values than those of the still image scanner group for all variables (P<.05), except in tolerance range. The root mean square, standard deviations, and mean negative precision values for the video scanner group were significantly higher than those for the other groups (P<.05). Digital impressions obtained by the intraoral video scanner showed better accuracy for long-span areas than those captured by the still image scanner. However, the video scanner was less accurate than the laboratory scanner. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Prevalence of dental anomalies in children with cleft lip and unilateral and bilateral cleft lip and palate.

    Science.gov (United States)

    Rullo, R; Festa, V M; Rullo, R; Addabbo, F; Chiodini, P; Vitale, M; Perillo, L

    2015-09-01

    To examine the prevalence of different types of dental anomalies in children with nonsyndromic cleft lip, unilateral cleft lip-palate, and bilateral cleft lip-palate. A sample of 90 patients (aged 4-20 years) affected by isolated cleft lip, unilateral and bilateral cleft lip and palate was examined. Cleft patients were classified into one of three groups according to cleft type: (1) Unilateral Cleft Lip-Palate, (2) Bilateral Cleft Lip-Palate, and (3) Cleft Lip. Intraoral exams, panoramic radiographs and dental casts, were used to analyse the prevalence of the various dental anomalies included in this study. There were no statistically significant differences between patients with cleft lip, unilateral cleft lip and palate and bilateral cleft lip and palate. The congenital absence of the cleft-side lateral incisor was observed in 40% of the sample, and a total of 30% patients showed supernumerary teeth at the incisors region. Second premolar agenesis was found in 4.4% of patients, whereas in 18.9% of the sample there was an ectopic dental eruption. Lateral or central incisors rotation was noted in 31.1% of the sample, while shape anomaly, lateral incisor microdontia, and enamel hypoplasia were detected respectively in 25.6%, 5.6% and 18.9% of cleft patients. High prevalence of different dental anomalies in children with cleft lip and unilateral and bilateral cleft lip and palate has been confirmed. This study, in particular, shows the presence of ectopic and rotated teeth in the cleft area.

  7. Precise positioning of an intraoral distractor using augmented reality in patients with hemifacial microsomia.

    Science.gov (United States)

    Qu, Miao; Hou, Yikang; Xu, Yourong; Shen, Congcong; Zhu, Ming; Xie, Le; Wang, Hao; Zhang, Yan; Chai, Gang

    2015-01-01

    Through three-dimensional real time imaging, augmented reality (AR) can provide an overlay of the anatomical structure, or visual cues for specific landmarks. In this study, an AR Toolkit was used for distraction osteogenesis with hemifacial microsomia to define the mandibular osteotomy line and assist with intraoral distractor placement. 20 patients with hemifacial microsomia were studied and were randomly assigned to experimental and control groups. Pre-operative computed tomography was used in both groups, whereas AR was used in the experimental group. Afterwards, pre- and post-operative computed tomographic scans of both groups were superimposed, and several measurements were made and analysed. Both the conventional method and AR technique achieved proper positioning of the osteotomy planes, although the AR was more accurate. The difference in average vertical distance from the coronoid and condyle process to the pre- and post-operative cutting planes was significant (p 0.05) was observed in the average angle between the two planes. The difference in deviations between the intersection points of the overlaid mandible across two cutting planes was also significant (p Augmented reality tools such as the AR Toolkit may be helpful for precise positioning of intraoral distractors in patients with hemifacial microsomia in craniofacial surgery. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition.

    Science.gov (United States)

    Rhee, Ye-Kyu; Huh, Yoon-Hyuk; Cho, Lee-Ra; Park, Chan-Jin

    2015-12-01

    The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For twodimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (Pimpression and the smallest difference was seen between dual-arch and full-arch impression. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P.05).

  9. A Novel Approach to Determine the Prevalence of Type of Soft Palate Using Digital Intraoral Impression

    Directory of Open Access Journals (Sweden)

    Saurabh Chaturvedi

    2017-01-01

    Full Text Available Aim. To determine the prevalence of type of soft palate in targeted population. Materials and Methods. Using computer technology in dentistry, intraoral digital scanner, and 3D analysis software tool, study was conducted. 100 patients selected from the outpatient clinics were divided into two groups based on the ages of 20–40 years and 41–60 years with equal ratio of males and females. Each selected patient’s maxillary arch was scanned with intraoral scanner; images so obtained were sectioned in anteroposterior cross section and with the 3D analysis software; the angulation between hard and soft palate was determined. Results. The prevalence of type II soft palate (angulation between hard and soft palate is between 10 and 45 degrees was highest, 60% in group 1 and 44% in group 2. The difference between genders was statistically significant with p value <0.05 in both the groups, although females had higher angulation compared to the males in all classes of both groups. Conclusions. In targeted population of Aseer Province, Saudi Arabia, the prevalence of type II soft palate was more common, with higher soft palate angulation among females. The advanced age had no effect in the type of soft palate in the region.

  10. Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition

    Science.gov (United States)

    Rhee, Ye-Kyu

    2015-01-01

    PURPOSE The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For twodimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (Pimpression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P.05). PMID:26816576

  11. Diagnostic Performance of the Intraoral Radiographs on the Interproximal Dental Caries

    International Nuclear Information System (INIS)

    Kim, Soo Ji; Kang, Byung Cheol

    1998-01-01

    The purpose of this study was to evaluated the diagnostic performance of the senior dental students for the proximal dental caries in intraoral radiographs and to compare it with the dental hospital residents, the reference group. It was also investigated the diagnostic performance according to the carious lesion depth. Thirty-five intraoral periapical and bitewing radiographs with 213 proximal surface included in this study were selected from the dental patients at Chonnam National University Hospital. The observers were 181 senior dental students from 5 dental schools and 40 dentists who were second year resident from 5 dental hospitals. They were asked to evaluate the presence ro the absence of the proximal dental caries. The results were as follows : 1. The mean of the hitting rate for the overall observers was 184.51 surfaces and the diagnostic accuracy was 86.62%. 2. The diagnostic performance of the sound proximal tooth surfaces was very high, i.e., 91.5% true negative rate and 8.5% false positive rate. 3. The diagnostic performance of the dentist group was higher than the student group (P 0.001).

  12. Effect of heat treatments on machinability of gold alloy with age-hardenability at intraoral temperature.

    Science.gov (United States)

    Watanabe, I; Baba, N; Watanabe, E; Atsuta, M; Okabe, T

    2004-01-01

    This study investigated the effect of heat treatment on the machinability of heat-treated cast gold alloy with age-hardenability at intraoral temperature using a handpiece engine with SiC wheels and an air-turbine handpiece with carbide burs and diamond points. Cast gold alloy specimens underwent various heat treatments [As-cast (AC); Solution treatment (ST); High-temperature aging (HA), Intraoral aging (IA)] before machinability testing. The machinability test was conducted at a constant machining force of 0.784N. The three circumferential speeds used for the handpiece engine were 500, 1,000 and 1,500 m/min. The machinability index (M-index) was determined as the amount of metal removed by machining (volume loss, mm(3)). The results were analyzed by ANOVA and Scheffé's test. When an air-turbine handpiece was used, there was no difference in the M-index of the gold alloy among the heat treatments. The air-turbine carbide burs showed significantly (pmachinability of the gold alloy using the air-turbine handpiece. The heat treatments had a small effect on the M-index of the gold alloy machined with a SiC wheel for a handpiece engine.

  13. Comparison of JPEG and wavelet compression on intraoral digital radiographic images

    International Nuclear Information System (INIS)

    Kim, Eun Kyung

    2004-01-01

    To determine the proper image compression method and ratio without image quality degradation in intraoral digital radiographic images, comparing the discrete cosine transform (DCT)-based JPEG with the wavelet-based JPEG 2000 algorithm. Thirty extracted sound teeth and thirty extracted teeth with occlusal caries were used for this study. Twenty plaster blocks were made with three teeth each. They were radiographically exposed using CDR sensors (Schick Inc., Long Island, USA). Digital images were compressed to JPEG format, using Adobe Photoshop v. 7.0 and JPEG 2000 format using Jasper program with compression ratios of 5 : 1, 9 : 1, 14 : 1, 28 : 1 each. To evaluate the lesion detectability, receiver operating characteristic (ROC) analysis was performed by the three oral and maxillofacial radiologists. To evaluate the image quality, all the compressed images were assessed subjectively using 5 grades, in comparison to the original uncompressed images. Compressed images up to compression ratio of 14: 1 in JPEG and 28 : 1 in JPEG 2000 showed nearly the same the lesion detectability as the original images. In the subjective assessment of image quality, images up to compression ratio of 9 : 1 in JPEG and 14 : 1 in JPEG 2000 showed minute mean paired differences from the original images. The results showed that the clinically acceptable compression ratios were up to 9 : 1 for JPEG and 14 : 1 for JPEG 2000. The wavelet-based JPEG 2000 is a better compression method, comparing to DCT-based JPEG for intraoral digital radiographic images.

  14. A Novel Method for Intraoral Access to the Superior Head of the Human Lateral Pterygoid Muscle

    Directory of Open Access Journals (Sweden)

    Aleli Tôrres Oliveira

    2014-01-01

    Full Text Available Background. The uncoordinated activity of the superior and inferior parts of the lateral pterygoid muscle (LPM has been suggested to be one of the causes of temporomandibular joint (TMJ disc displacement. A therapy for this muscle disorder is the injection of botulinum toxin (BTX, of the LPM. However, there is a potential risk of side effects with the injection guide methods currently available. In addition, they do not permit appropriate differentiation between the two bellies of the muscle. Herein, a novel method is presented to provide intraoral access to the superior head of the human LPM with maximal control and minimal hazards. Methods. Computational tomography along with digital imaging software programs and rapid prototyping techniques were used to create a rapid prototyped guide to orient BTX injections in the superior LPM. Results. The method proved to be feasible and reliable. Furthermore, when tested in one volunteer it allowed precise access to the upper head of LPM, without producing side effects. Conclusions. The prototyped guide presented in this paper is a novel tool that provides intraoral access to the superior head of the LPM. Further studies will be necessary to test the efficacy and validate this method in a larger cohort of subjects.

  15. Elemental, microstructural, and mechanical characterization of high gold orthodontic brackets after intraoral aging.

    Science.gov (United States)

    Hersche, Sepp; Sifakakis, Iosif; Zinelis, Spiros; Eliades, Theodore

    2017-02-01

    The purpose of the present study was to investigate the elemental composition, the microstructure, and the selected mechanical properties of high gold orthodontic brackets after intraoral aging. Thirty Incognito™ (3M Unitek, Bad Essen, Germany) lingual brackets were studied, 15 brackets as received (control group) and 15 brackets retrieved from different patients after orthodontic treatment. The surface of the wing area was examined by scanning electron microscopy (SEM). Backscattered electron imaging (BEI) was performed, and the elemental composition was determined by X-ray EDS analysis (EDX). After appropriate metallographic preparation, the mechanical properties tested were Martens hardness (HM), indentation modulus (EIT), elastic index (ηIT), and Vickers hardness (HV). These properties were determined employing instrumented indentation testing (IIT) with a Vickers indenter. The results were statistically analyzed by unpaired t-test (α=0.05). There were no statistically significant differences evidenced in surface morphology and elemental content between the control and the experimental group. These two groups of brackets showed no statistically significant difference in surface morphology. Moreover, the mean values of HM, EIT, ηIT, and HV did not reach statistical significance between the groups (p>0.05). Under the limitations of this study, it may be concluded that the surface elemental content and microstructure as well as the evaluated mechanical properties of the Incognito™ lingual brackets remain unaffected by intraoral aging.

  16. Radiation protection and quality assurance in dental radiology: I. Intraoral radiography

    International Nuclear Information System (INIS)

    Martinez-Beneyto, Y.; Alcaraz, M.; Jodar-Porlan, S.; Saura-Iniesta, A.M.; Velasco-Hidalgo, E.

    2001-01-01

    This paper studies 2524 official reports on quality assurance in dental radiography, made in the context of the three first revisions of these dental clinics as a result of the entry into force of the regulations establishing the duties for these types of facilities. In the results section we present a quantitative analysis of the facilities equipped with an intraoral device, making a special reference to the brands they have available, as well as their physical features (KV, mAs, filtration, length of cone) and the deviations detected in their operation. Some of the features in the process of obtaining radiological images at those facilities (film control, development time, liquid renewal) are determined, and the average dose of ionizing radiation used in order to obtain the radiological image of the same tooth is presented. This paper shows, in a quantitative way, the characteristic features of intraoral dental radiology in our medium. The study is intended to be continued during the next years, which would allow the assessment of the prospective improvement in dental radiological performances as a result of the newly established regulations. (author)

  17. Simulation of dental intensifying screen for intraoral radiographic using MCNP5 code

    International Nuclear Information System (INIS)

    Ferreira, Vanessa M.; Oliveira, Renato C.M.; Barros, Graiciany P.; Oliveira, Arno H.; Veloso, M. Auxiliadora F.

    2011-01-01

    One of basic principles for radiological protection is the optimization of techniques for obtain radiographic images, in way that the dose in the patient is kept as low as reasonably achievable (ALARA). Intensifying screens are used in medical radiology, which reduce considerably the dose rates in the production of radiographic images, maintaining the quality of these, while in dental radiology, there is no a intensifying screen available for intraoral examinations. From this technological requirement, this paper evaluates a computational modeling of an intensifying screen for use in intraoral radiography. For this, it was used the Monte Carlo code MCNP5 that allows the radiography simulation through the transport of electrons and photons in the different materials present in this examination. The goal of an intensifying screen is the conversion of X-ray photons to photons in the visible spectrum, knowing that radiographic films are more sensitive to light photons than to X-ray photons. So the screen should be composed of an efficient material for converting x-rays photons in light photons, therefore was made simulations using different materials, thicknesses and positions possible for placing screen in radiographic film in order to find the way more technically feasible. (author)

  18. Intraoral conversion of occlusal force to electricity and magnetism by biting of piezoelectric elements.

    Science.gov (United States)

    Kameda, Takashi; Ohkuma, Kazuo; Sano, Natsuki; Ogura, Hideo; Terada, Kazuto

    2012-01-01

    Very weak electrical, magnetic and ultrasound signal stimulations are known to promote the formation, metabolism, restoration and stability of bone and surrounding tissues after treatment and operations. We have therefore investigated the possibility of intraoral generation of electricity and magnetism by occlusal force in an in vitro study. Biting bimorph piezoelectric elements with lead zirconate titanate (PZT) using dental models generated appropriate magnetism for bone formation, i. e. 0.5-0.6 gauss, and lower electric currents and higher voltages, i. e. 2.0-6.0 μA at 10-22 V (appropriate levels are 30 μA and 1.25 V), as observed by a universal testing machine. The electric currents and voltages could be changed using amplifier circuits. These results show that intraoral generation of electricity and magnetism is possible and could provide post-operative stabilization and activation of treated areas of bone and the surrounding tissues directly and/or indirectly by electrical, magnetic and ultrasound stimulation, which could accelerate healing.

  19. Absorbed doses from intraoral radiography with special emphasis on collimator dimensions

    International Nuclear Information System (INIS)

    Stenstroem, B.; Henrikson, C.O.; Holm, B.; Richter, S.; Huddinge Univ. Hospital, Huddinge

    1986-01-01

    Thermoluminescence dosimeters were used in a phantom head and on patients to measure the absorbed dose to organs of special interest from full surveys with intraoral films (20 exposures) and single bitewing exposures. Two x-ray machines were used, operating at 65 kVp. The apertures of the circular tube collimators had diameters of 55 mm and 48 mm. Rectangular (35 mm x44 mm) tube collimators were also used. The distance from the x-ray focus to the open end of the collimators (FSD) was 0.20 and 0.35 m. Exposure values for Kodak Ultra-Speed film (speed group D) were used. The maximum skin dose measured from the full surveys decreased by 25 per cent on changing from the circular to the rectangular apertures. Using 0.35 m FSD and rectangular collimator the maximum skin dose was 13 mGy. The absorbed doses to the salivary glands and the thyroid gland were significantly reduced on changing from circular to rectangular apertures. The doses in the central part of the parotid and the thyroid glands were then 0.5 and 0.12 mGy, respectively, from a full survey with 20 intraoral films. With a leaded shield the thyroid dose was reduced to 0.05 mGy. All dose values could be further reduced by 40 per cent by using Kodak Ektaspeed film (speed group E)

  20. A Novel Approach to Determine the Prevalence of Type of Soft Palate Using Digital Intraoral Impression

    Science.gov (United States)

    Khaled Addas, Mohamed; Al Humaidi, Abdullah Saad Ali; Al Qahtani, Abdulrazaq Mohammed; Al Qahtani, Mubarak Daghash

    2017-01-01

    Aim To determine the prevalence of type of soft palate in targeted population. Materials and Methods Using computer technology in dentistry, intraoral digital scanner, and 3D analysis software tool, study was conducted. 100 patients selected from the outpatient clinics were divided into two groups based on the ages of 20–40 years and 41–60 years with equal ratio of males and females. Each selected patient's maxillary arch was scanned with intraoral scanner; images so obtained were sectioned in anteroposterior cross section and with the 3D analysis software; the angulation between hard and soft palate was determined. Results The prevalence of type II soft palate (angulation between hard and soft palate is between 10 and 45 degrees) was highest, 60% in group 1 and 44% in group 2. The difference between genders was statistically significant with p value <0.05 in both the groups, although females had higher angulation compared to the males in all classes of both groups. Conclusions In targeted population of Aseer Province, Saudi Arabia, the prevalence of type II soft palate was more common, with higher soft palate angulation among females. The advanced age had no effect in the type of soft palate in the region. PMID:28951740

  1. Bilateral absence of musculocutaneous nerve

    Directory of Open Access Journals (Sweden)

    Mathada V Ravishankar

    2012-01-01

    Full Text Available Brachial plexus is an important group of spinal nerve plexus that supplies the muscles of the upper limb via the ventral rami of the Cervical 5 - Thoracic 1 fibers of the spinal nerves. It is not uncommon to notice the variations during cadaveric dissections in many regions of the body, at different levels, such as, roots, trunks, division, cords, communications, and branches as reported in the literature. Although the nerve supply of the body musculature takes place in the fetal life itself, its course, branching pattern, innervations, and communication can show variable patterns as the fetal development progresses. One such anomaly was noticed during our routine cadaveric dissection in the Department of Anatomy, Jawaharlal Nehru Medical College, Belgaum, showing bilateral absence of the musculocutaneous nerve, which obviously drew the attention of the students of medicine, physiotherapy, and learning clinicians as well.

  2. Bilateral supernumerary primary maxillary canines

    Directory of Open Access Journals (Sweden)

    Santanu Mukhopadhyay

    2018-01-01

    Full Text Available Supernumerary teeth are more common in the permanent than in primary dentition. In the primary dentition, the anomaly is most frequently observed in the maxillary lateral incisor region, followed by the maxillary midline where they are termed as mesiodens. Supernumerary teeth in the primary canine region are rare. This paper describes a rare case of nonsyndromic supernumerary primary maxillary canine distributed bilaterally in a 4-year-old boy. Both the supernumeraries resembled size and shape of normal primary canine. The right supplemental canine is high labially placed, whereas the left one is seen normally aligned in the dental arch distal to lateral incisor. One of the most significant sequelae of primary supernumerary teeth is their duplication in the permanent series. Radiographic examination of supernumerary primary canine did not indicate any such anomaly in the permanent dentition. The patient was kept under observation.

  3. Pielonefritis enfisematosa aguda bilateral: Un desafío terapéutico Acute bilateral emphysematous pyelonephritis: A therapeutic challenge

    Directory of Open Access Journals (Sweden)

    Marcelo J. Melero

    2007-06-01

    Full Text Available La pielonefritis enfisematosa es una forma poco común de infección renal, caracterizada por la presencia de bacterias coliformes productoras de gas que afecta preferentemente a los pacientes diabéticos. Comunicamos el caso de una mujer diabética de 57 años de edad que ingresó en el hospital por un shock séptico, signos de pielonefritis enfisematosa aguda bilateral y cetoacidosis diabética. En los cultivos de las muestras de orina y sangre desarrolló Escherichia coli. La paciente fue tratada exitosamente con antibióticos de amplio espectro por un tiempo prolongado, control diabético y medidas de sostén solamente. No fue necesario el drenaje con catéteres o la nefrectomía para superar esta situación potencialmente letal.Emphysematous pyelonephritis is a rare form of kidney infection characterized by the presence of gas-forming coliform bacteria which affects more frequently diabetic subjects. We report the case of a 57-years-old diabetic woman, who was admitted in septic shock, signs of acute bilateral emphysematous pyelonephritis, and diabetic ketoacidosis. Both blood and urine cultures yielded Escherichia coli. The patient was successfully treated using long-term broad-spectrum antibiotics, diabetic control and supportive measures alone. Catheter drainage and nephrectomy were not necessary to overcome this life threatening situation.

  4. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures

    Directory of Open Access Journals (Sweden)

    Gultekin Gulbahar

    2015-01-01

    Full Text Available First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity.

  5. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures

    OpenAIRE

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare en...

  6. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures.

    Science.gov (United States)

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity.

  7. Comparison of cone - beam computed tomography and intraoral radiography in detection of recurrent caries under composite restorations

    Energy Technology Data Exchange (ETDEWEB)

    Kasraei, Shahin; Shokri, Abbas; Poorolajal, Jalal; Rahmani, Hamid, E-mail: Dr.a.shokri@gmail.com [Hamadan University of Medical Sciences Hamadan (Iran, Islamic Republic of); Khajeh, Samira [Kurdistan University of Medical Sciences, Sanandaj (Iran, Islamic Republic of)

    2017-01-15

    Secondary caries is the most common cause of dental restoration failures. This study aimed to compare the diagnostic accuracy of conventional and digital intraoral radiography and cone beam computed tomography (CBCT) for detection of recurrent caries around composite restorations mesio-occluso-distal (MOD) cavities were prepared using bur on 45 extracted sound human molar teeth. The teeth were divided into 3 groups. In the control group, cavities were restored with composite resin after etching and bonding (n=15). In Group 2, 500-μm thick wax was placed over the buccal, lingual and gingival walls and the cavities were restored with composite resin. Group 3 specimens were subjected to pH cycling and artificial caries were created on the buccal, lingual and gingival walls. The cavities were restored with composite. Conventional and digital photo-stimulable phosphor (PSP; Optime) radiographs and two CBCTs images (NewTom 3G and Cranex 3D) were obtained from them. Presence or absence of caries in the cavity walls was assessed on these images. Data were analyzed using Kappa statistic. The diagnostic accuracy of CBCT was significantly higher than that of digital and conventional intraoral radiography (p<0.05). The accuracy was 0.83, 0.78, 0.55 and 0.49 for CBCT Cranex 3D, CBCT NewTom 3G, conventional and digital intraoral radiography, respectively. CBCT has a higher diagnostic accuracy than digital and conventional intraoral radiography for detection of secondary caries around composite restorations. (author)

  8. Stereologic, histopathologic, flow cytometric, and clinical parameters in the prognostic evaluation of 74 patients with intraoral squamous cell carcinomas

    DEFF Research Database (Denmark)

    Bundgaard, T; Sørensen, Flemming Brandt; Gaihede, M

    1992-01-01

    BACKGROUND AND METHODS: A consecutive series of all 78 incident cases of intraoral squamous cell carcinoma occurring during a 2-year period in a population of 1.4 million inhabitants were evaluated by histologic score (the modified classification of Jacobsson et al.), flow cytometry, stereology, ...

  9. Patients' preferences when comparing analogue implant impressions using a polyether impression material versus digital impressions (Intraoral Scan) of dental implants

    NARCIS (Netherlands)

    Wismeijer, D.; Mans, R.S.; Van Genuchten, M.J.I.M; Reijers, H.A.

    2014-01-01

    Objectives: The primary objective of this clinical study was to assess the patients' perception of the difference between an analogue impression approach on the one hand and an intra-oral scan (IO scan) on the other when restoring implants in the non-aesthetic zone. A second objective was to analyse

  10. Patients' preferences when comparing analogue implant impressions using a polyether impression material versus digital impressions (Intraoral Scan) of dental implants

    NARCIS (Netherlands)

    Wismeijer, D.; Mans, R.; van Genugten, M.; Reijers, H.A.

    2014-01-01

    Objectives The primary objective of this clinical study was to assess the patients' perception of the difference between an analogue impression approach on the one hand and an intra-oral scan (IO scan) on the other when restoring implants in the non-aesthetic zone. A second objective was to analyse

  11. Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling.

    Science.gov (United States)

    Syrek, Andreas; Reich, Gunnar; Ranftl, Dieter; Klein, Christoph; Cerny, Barbara; Brodesser, Jutta

    2010-07-01

    The aim of the present study was to compare the fit of all-ceramic crowns fabricated from intraoral digital impressions with the fit of all-ceramic crowns fabricated from silicone impressions. Twenty patients agreed to take part in the study to receive two Lava crowns each for the same preparation. One crown was fabricated from intraoral scans using the Lava Chairside Oral Scanner (Lava C.O.S.), and the other crown from a two-step silicone impression. Prior to cementation the fit of both crowns was clinically evaluated by two calibrated and blinded examiners; the marginal fit was also scored from replicas. Data from the replica scores were analysed by Anderson-Darling test, Levene's test and Mann-Whitney test. All tests were performed with alpha-level of 0.05. Median marginal gap in the conventional impression group was 71microm (Q1:45microm; Q3:98microm), and in the digital impression group 49microm (Q1:32microm; Q3:65microm). Mann-Whitney test revealed a significant difference between the groups (pdigitally fabricated crowns. 1. Crowns from intraoral scans revealed significantly better marginal fit than crowns from silicone impressions. 2. Marginal discrepancies in both groups were within the limits of clinical acceptability. 3. Crowns from intraoral scans tended to show better interproximal contact area quality. 4. Crowns from both groups performed equally well with regard to occlusion. Copyright 2010 Elsevier Ltd. All rights reserved.

  12. Age and gender differences in mechanically induced intraoral temporal summation and conditioned pain modulation in healthy subjects.

    Science.gov (United States)

    Khan, Junad; Korczeniewska, Olga; Benoliel, Rafael; Kalladka, Mythili; Eliav, Eli; Nasri-Heir, Cibelle

    2018-04-13

    The aim of this study was to investigate intraoral temporal summation (TS) and conditioned pain modulation (CPM) and compare the outcome with TS and CPM induced in the forearm. In addition, we aimed to study the effect of age and gender on intraoral and forearm TS and CPM. Mechanical stimulation was induced with # 5.46 von Frey filament applying 26 grams of force. A single stimulus, followed by a train of 30 successive stimuli, was applied intraorally and to the dominant forearm. CPM was assessed with the TS test as the painful stimulus and with immersion of the nondominant hand in a hot water bath as the conditioning stimulus. Gender was significantly associated with TS but not with CPM measures. Females had significantly lower mean TS measured in the face and in the dominant forearm compared with males. Age was significantly associated with CPM, but not with TS measures. In both sites examined, older patients had significantly lower mean CPM compared with younger patients. Mechanical TM elicited in the oral cavity can be used as test stimulus for CPM testing. Intraoral modulation, both TS and CPM, has an extent similar to that of the standard cutaneous extremity. TS was lower in females, and CPM was reduced with age. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Comparison of cone - beam computed tomography and intraoral radiography in detection of recurrent caries under composite restorations

    International Nuclear Information System (INIS)

    Kasraei, Shahin; Shokri, Abbas; Poorolajal, Jalal; Rahmani, Hamid; Khajeh, Samira

    2017-01-01

    Secondary caries is the most common cause of dental restoration failures. This study aimed to compare the diagnostic accuracy of conventional and digital intraoral radiography and cone beam computed tomography (CBCT) for detection of recurrent caries around composite restorations mesio-occluso-distal (MOD) cavities were prepared using bur on 45 extracted sound human molar teeth. The teeth were divided into 3 groups. In the control group, cavities were restored with composite resin after etching and bonding (n=15). In Group 2, 500-μm thick wax was placed over the buccal, lingual and gingival walls and the cavities were restored with composite resin. Group 3 specimens were subjected to pH cycling and artificial caries were created on the buccal, lingual and gingival walls. The cavities were restored with composite. Conventional and digital photo-stimulable phosphor (PSP; Optime) radiographs and two CBCTs images (NewTom 3G and Cranex 3D) were obtained from them. Presence or absence of caries in the cavity walls was assessed on these images. Data were analyzed using Kappa statistic. The diagnostic accuracy of CBCT was significantly higher than that of digital and conventional intraoral radiography (p<0.05). The accuracy was 0.83, 0.78, 0.55 and 0.49 for CBCT Cranex 3D, CBCT NewTom 3G, conventional and digital intraoral radiography, respectively. CBCT has a higher diagnostic accuracy than digital and conventional intraoral radiography for detection of secondary caries around composite restorations. (author)

  14. Bilateral Simultaneous Macular Infarction with Spontaneous Visual ...

    African Journals Online (AJOL)

    To report the rare and dramatic event of bilateral macular infarction in a sickle cell hemoglobinopathy (SS genotype) patient, resulting in bilateral severe reduction in visual acuity. Without any intervention, the patient's vision gradually improved over the follow‑up period. Central visual field defects however persisted.

  15. Bilateral microperc in a severe kyphoscoliosis

    OpenAIRE

    Dağgülli, Mansur; Penbegül, Necmettin; Dede, Onur; Utanğaç, Mehmet Mazhar

    2016-01-01

    Percutaneous nephrolithotomy is the standard modality for large renal calculi in normal and abnormal renal anatomic situations. This case report describes a 57-year-old male patient who presented with bilateral kidney stones and severe kyphoscoliosis. He had successfully been treated with a bilateral microperc technique.

  16. Infectious mononucleosis presenting as bilateral acute dacryocystitis.

    Science.gov (United States)

    Atkinson, P L; Ansons, A M; Patterson, A

    1990-01-01

    A case of infectious mononucleosis presenting as bilateral acute dacryocystitis in a 7-year-old girl is reported. Acute dacryocystitis is uncommon in this age group, and an underlying systemic illness should be suspected particularly when it is bilateral. Images PMID:2275940

  17. Bilateral elastofibroma dorsi: A case report

    OpenAIRE

    Molini, L.; Ciortan, E.; Bianchi, S.

    2010-01-01

    Elastofibroma dorsi is a rare pseudotumoral lesion located in the periscapular region. Ultrasound can be used to evaluate its dimensions, margins, and internal structure. In the presence of bilateralism, diagnosis can be made on the basis of clinical and sonographic findings. The authors present a case of bilateral elastofibroma dorsi in which the clinical and ultrasound diagnosis was confirmed by magnetic resonance imaging.

  18. Bilateral locked facets in the thoracic spine

    NARCIS (Netherlands)

    M.H.A. Willems; Braakman, R. (Reinder); B. van Linge (Bert)

    1984-01-01

    textabstractTwo cases of traumatic bilateral locked facets in the thoracic spine are reported. Both patients had only minor neurological signs. They both made a full neurological recovery after surgical reduction of the locked facets. Bilateral locked facets are very uncommon in the thoracic spine.

  19. Bilateral spontaneous adrenal haemorrhage complicating acute pancreatitis

    International Nuclear Information System (INIS)

    Pianta, M.; Varma, D. K.

    2007-01-01

    Bilateral adrenal haemorrhage is an event that mandates prompt diagnosis and treatment to prevent primary adrenocortical insufficiency and potential death. Presentation can be non-specific and incidentally diagnosed with imaging alone, primarily CT. We present a case of acute pancreatitis with spontaneous bilateral adrenal haemorrhage and briefly discuss imaging and treatment implications

  20. A case of bilateral trench foot.

    Science.gov (United States)

    Parsons, S L; Leach, I H; Charnley, R M

    1993-12-01

    A case of severe bilateral trench foot is presented in a patient who lived rough for 3 weeks without removing his boots. Non-operative management yielded no clinical improvement and bilateral below-knee amputation was necessary. Histology revealed subcutaneous and muscle necrosis with secondary arterial thrombosis.

  1. Processing of Intraoral Olfactory and Gustatory Signals in the Gustatory Cortex of Awake Rats.

    Science.gov (United States)

    Samuelsen, Chad L; Fontanini, Alfredo

    2017-01-11

    The integration of gustatory and olfactory information is essential to the perception of flavor. Human neuroimaging experiments have pointed to the gustatory cortex (GC) as one of the areas involved in mediating flavor perception. Although GC's involvement in encoding the chemical identity and hedonic value of taste stimuli is well studied, it is unknown how single GC neurons process olfactory stimuli emanating from the mouth. In this study, we relied on multielectrode recordings to investigate how single GC neurons respond to intraorally delivered tastants and tasteless odorants dissolved in water and whether/how these two modalities converge in the same neurons. We found that GC neurons could either be unimodal, responding exclusively to taste (taste-only) or odor (odor-only), or bimodal, responding to both gustatory and olfactory stimuli. Odor responses were confirmed to result from retronasal olfaction: monitoring respiration revealed that exhalation preceded odor-evoked activity and reversible inactivation of olfactory receptors in the nasal epithelium significantly reduced responses to intraoral odorants but not to tastants. Analysis of bimodal neurons revealed that they encode palatability significantly better than the unimodal taste-only group. Bimodal neurons exhibited similar responses to palatable tastants and odorants dissolved in water. This result suggested that odorized water could be palatable. This interpretation was further supported with a brief access task, where rats avoided consuming aversive taste stimuli and consumed the palatable tastants and dissolved odorants. These results demonstrate the convergence of the chemosensory components of flavor onto single GC neurons and provide evidence for the integration of flavor with palatability coding. Food perception and choice depend upon the concurrent processing of olfactory and gustatory signals from the mouth. The primary gustatory cortex has been proposed to integrate chemosensory stimuli

  2. Fascitis necrosante bilateral: a propósito de un caso Bilateral necrotizing fasciitis: case report

    Directory of Open Access Journals (Sweden)

    F. Fernández Gómez

    2011-06-01

    Full Text Available La fascitis necrosante es una enfermedad de origen infeccioso que afecta a la fascia muscular y progresa rápidamente. Para el manejo de este tipo de pacientes es clave un diagnóstico precoz y un tratamiento adecuado que combine antibioticoterapia y cirugía. Presentamos el caso de una paciente de 77 años de edad con diagnóstico de fascitis necrosante de presentación atípica por la bilateralidad de las lesiones, la ausencia de factores predisponentes y la presencia de un único germen causal.Necrotizing fasciitis is an infectious disease that involves muscular fascia and has a quickly progress. Early diagnosis and proper treatment that consists on antibiotic therapy and surgery are the key of patient management. We report the case of a 77 years old oman with necrotizing fasciitis diagnosis with atypical presentation due to bilateral skin lesions, lack of risk factors and only one germ as causal pathogen.

  3. The Efficacy of Postoperative Prophylactic Antibiotics in Orthognathic Surgery: A Prospective Study in Le Fort I Osteotomy and Bilateral Intraoral Vertical Ramus Osteotomy

    Science.gov (United States)

    Kang, Sang-Hoon; Yoo, Jae-Ha

    2009-01-01

    Purpose This study examined the efficacy of the postoperative prophylactic antibiotics used in orthognathic surgery. The prevalence of surgical site infections (SSIs) was determined according to the use of postoperative prophylactic antibiotics. Patients and Methods Fifty-six patients were divided into 2 groups. Each patient intravenously received 1.0 g of a third-generation cephalosporin (Cefpiramide) 30 minutes before surgery. Among them, 28 patients in the control group received 1.0 g Cefpiramide twice daily until the third day after surgery. The postoperative wounds were examined regularly for the presence of infectious signs. Results There was no significant difference in the incidence of postoperative wound infections between patients who had received postoperative prophylactic antibiotic administration and those who had not (p = 0.639). Conclusion Prolonged prophylactic antibiotic use after orthognathic surgery may not be necessary, provided that there are no other significant factors for wound infections. PMID:19259349

  4. Bilateral Transport Cost, Infrastructure, Common Bilateral Ties and Political Stability.

    Directory of Open Access Journals (Sweden)

    Danielken Molina

    2010-05-01

    Full Text Available Los costos de transporte son una de las más importantes fuentes de barreras al comercio. Inspirados por este aspecto, utilizamos un modelo empírico ad-hoc con el fin de examinar los posibles determinantes de los costos de transporte. Utilizando una base de datos de costos de transporte bilaterales para el año 1990, replicamos el trabajo de Limao y Venables (2001 y encontramos que el efecto de su ´índice de infraestructura sobre los costos de transporte no es robusto. Siguiendo a Micco (2004 y Micco y Serebrinzky (2005 calculamos dos ´índices alternativos de infraestructura. Utilizando estos ´índices encontramos que aparte de la distancia, la infraestructura, la estabilidad política, las relaciones bilaterales comunes y los acuerdos de cielos abiertos son otros importantes canales mediante los cuales los costos de transporte pueden reducirse.

  5. Intraoral Approach and Stereolithographic-guided Large Mandibular Reconstruction with Fibula Free Flap

    Directory of Open Access Journals (Sweden)

    Artur Diaz-Carandell, MD

    2014-08-01

    Full Text Available Summary: The reconstruction of mandibular defects has always been of great concern, and it still represents a challenge for head-and-neck reconstructive surgeons. The mandible plays a major role in mastication, articulation, swallowing, respiration, and facial contour. Thus, when undertaking mandibular reconstruction, restoration of both function and cosmetics should be considered as the measure of success. Microsurgical reconstruction is the gold-standard method to repair a segmental mandibular defect. Reconstruction of sizeable defects often needs a large neck incision, leading to unsatisfactory cosmetic outcomes. Virtual surgical planning and stereolithographic modeling are new techniques that offer excellent results and can provide precise data for mandibular reconstruction and improve postoperative outcomes. We present a case of complete intraoral resection and reconstruction of a large ameloblastoma of the mandible.

  6. Use of monocortical miniplates for the intraoral treatment of mandibular fractures.

    Science.gov (United States)

    Chiodo, Thomas A; Milles, Maano

    2009-03-01

    Fixation of mandibular fractures using rigid hardware has gained wide acceptance over the past 3 decades. The goal of rigid internal fixation is to allow for fracture healing with limited, or no, time in maxillo-mandibular fixation. There has been significant evolution in plate and screw materials and design over the past 30 years. The term miniplate is used to describe a fracture plate with a screw diameter of 2.0 mm or less. With correct diagnosis and understanding of the forces affecting mandible fractures, miniplates can be applied transorally in various situations, allowing for less invasive treatment with open reduction of mandible fractures. This article describes the use of monocortical miniplates for the intraoral treatment of mandibular fractures.

  7. Cone beam computed tomography and intraoral radiography for diagnosis of dental abnormalities in dogs and cats

    International Nuclear Information System (INIS)

    Roza, Marcello R.; Fioravanti, Maria Clorinda S.; Silva, Luiz Antonio F.; Barriviera, Mauricio; Januario, Alessandro L.; Bezerra, Ana Cristina B.

    2011-01-01

    The development of veterinary dentistry has substantially improved the ability to diagnose canine and feline dental abnormalities. Consequently, examinations previously performed only on humans are now available for small animals, thus improving the diagnostic quality. This has increased the need for technical qualification of veterinary professionals and increased technological investments. This study evaluated the use of cone beam computed tomography and intraoral radiography as complementary exams for diagnosing dental abnormalities in dogs and cats. Cone beam computed tomography was provided faster image acquisition with high image quality, was associated with low ionizing radiation levels, enabled image editing, and reduced the exam duration. Our results showed that radiography was an effective method for dental radiographic examination with low cost and fast execution times, and can be performed during surgical procedures

  8. Coat-sleeve type giant congenital melanocytic nevus with intraoral blue nevus: A rare case report

    Directory of Open Access Journals (Sweden)

    Lata M Kale

    2017-01-01

    Full Text Available Congenital melanocytic nevi (CMN are visible hyperpigmented (melanocytic, benign, tumor like proliferations in the skin resulting from faulty development of pigment cell precursors in the embryo, and are composed of an abnormal mixture of skin elements. Giant congenital melanocytic nevus (GCMN is usually defined as a melanocytic lesion present at birth that will reach a larger size in adulthood. GCMN is a rare variety of CMN which is characterized by its size (diameter ≥20 cm and the potential for malignant transformation. It is infrequently associated with other findings, which makes the clinical picture complex. In this case, we report a rare association of GCMN with intraoral blue nevus in a 24-year-old male patient.

  9. Bilateral bone conduction devices: improved hearing ability in children with bilateral conductive hearing loss.

    Science.gov (United States)

    Dun, Catharina A J; Agterberg, Martijn J H; Cremers, Cor W R J; Hol, Myrthe K S; Snik, Ad F M

    2013-01-01

    The aim of the study was to investigate whether children with bilateral conductive hearing loss benefit from their second device (i.e., the bilateral bone conduction device [BCD]). Speech recognition in noise was assessed in 10 children fitted with bilateral BCDs during childhood. Speech recognition was measured in 2 conditions with both BCDs active. Spatial resolution was tested with the Minimum Audible Angle test in the bilateral and monaural listening conditions. Children demonstrated an improvement in speech recognition when speech was presented from the front and noise was presented from the right-hand side as compared with both speech and noise being presented from the front. The minimum audible angle decreased from 57° in the best monaural condition to 13° in the bilateral condition. The audiological outcomes demonstrate the advantage of bilateral BCD fitting in children with bilateral conductive hearing loss.

  10. Diagnostic Accuracy of Quantitative Sensory Testing to Discriminate Inflammatory Toothache and Intraoral Neuropathic Pain.

    Science.gov (United States)

    Porporatti, André Luís; Costa, Yuri Martins; Stuginski-Barbosa, Juliana; Bonjardim, Leonardo Rigoldi; Duarte, Marco Antônio Hungaro; Conti, Paulo César Rodrigues

    2015-10-01

    A differential diagnosis between inflammatory toothache (IT) and intraoral neuropathic pain is challenging. The aim of this diagnostic study was to quantify somatosensory function of subjects with IT (acute pulpitis) and atypical odontalgia (AO, intraoral neuropathic pain) and healthy volunteers and to quantify how accurately quantitative sensory testing (QST) discriminates an IT or AO diagnosis. The sample consisted of 60 subjects equally divided (n = 20) into 3 groups: (1) IT, (2) AO, and (3) control. A sequence of 4 QST methods was performed over the dentoalveolar mucosa in the apical maxillar or mandibular area: mechanical detection threshold, pain detection threshold (PDT), dynamic mechanical allodynia, and temporal summation. One-way analysis of variance, Tukey post hoc analyses, and z score transformation were applied to the data. In addition, the receiver operating characteristic curve analysis, diagnostic accuracy, sensitivity, specificity, likelihood ratios, and diagnostic odds ratio of the QST methods were calculated (α = 5%). Somatosensory abnormalities were found for the AO group, which is consistent with a low detection threshold to touch and pain and the presence of mechanical allodynia. For the IT group, no somatosensory abnormality was observed when compared with the control group. The most accurate QST to discriminate the diagnostic differences between IT and healthy individuals is the PDT. The diagnostic differences between AO and healthy individuals and between IT and AO are best discriminated with the mechanical detection threshold, PDT, and dynamic mechanical allodynia. The proposed QST methods may aid in the differential diagnosis between IT and AO with strong accuracy and may be used as complementary diagnostic tests. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Intraoral Salivary Duct Cyst: Clinical and Histopathologic Features of 177 Cases.

    Science.gov (United States)

    Stojanov, Ivan J; Malik, Umer A; Woo, Sook-Bin

    2017-12-01

    The salivary duct cyst (SDC) is a reactive ductal ectasia most frequently seen in major salivary glands, and likely caused by obstruction. The aim of this study is to define the clinical and histopathologic spectrum of intraoral SDCs. Cases were retrieved from the archives of Harvard School of Dental Medicine/StrataDx, Inc. from January 2012 to August 2014. There were 177 cases of which 103 (58.2%) occurred in females, with a median age of 56 (range 2-95). Approximately half of cases (45.8%) presented in the area of the buccal mucosa, lower lip mucosa, or mandibular vestibule, and 23.2% presented in the floor of mouth. SDCs were lined at least focally by 1-2 layers of cuboidal/columnar epithelium in 85.3% of cases and showed varying degrees of metaplasia (oncocytic, mucous cell, squamous, ciliated, apocrine-like) in 68.4% of cases. Intraluminal mucous stasis was present in 41.8% of SDCs, incipient calcification was present within 4.5% of SDCs, and chronic obstructive sialadenitis was seen in 90.2% of cases. No cysts showed adenomatous ductal proliferations or true papillary structures with fibrovascular cores, although 41.2% exhibited reactive undulation of cyst lining. Thirty-nine 'papillary oncocytic cystadenoma-like' SDCs (22.0%) demonstrated complete oncocytic metaplasia and marked undulation. An additional seven such cysts (4.0%) had a 'Warthin tumor-like' lymphoplasmacytic infiltrate. Intraoral SDCs occur most commonly in the sixth decade of life in locations distinct from extravasation mucoceles, likely secondary to intraluminal obstruction. SDCs show diverse histopathology and certain phenotypic variants may be mistaken for papillary oncocytic cystadenoma or Warthin tumor.

  12. Dose and risk evaluation to the thyroid gland in intra-oral dental radiology

    International Nuclear Information System (INIS)

    Souza, Edmilson M.; Lima, Marco A.F.; Kelecom, Alphonse; Correa, Samanda C.A.; Silva, Ademir X.; Brito, Alan

    2008-01-01

    Intra-oral technique is one of the most frequently used procedures of dental radiology, allowing the detection of a variety of dental anomalies such as caries, dental trauma and periodontal lesions, while exposing patients to relatively low doses of radiation. However, although the adverse effects of doses generated by dental radiology are essentially stochastic, a number of epidemiological studies have provided evidence of an increased risk of thyroid tumors for dental radiography. Many studies have measured doses of radiation for dental radiography, but only a few have estimated thyroid dose. Furthermore, most of the studies on dose evaluation in dental radiology are based on standardized calculation phantoms, which neglect the variance of the patient size or even sex. The purpose of this study is to use the Monte Carlo code MCNPX and the FAX (Female Adult voXel) and MAX (Male Adult voXel) phantoms to investigate how absorbed doses to the thyroid gland in intraoral dental examinations vary in female and male patients. The lifetime cancer incidence attributable to dental examinations were estimated using the Biological Effects of Ionizing Radiations (BEIR) VII Committee Report. The phantoms study proved a useful trial for detecting the radiation dose to the thyroid gland and conclusively supported that the anatomy may be regarded as an influencing factor in radiation dose received during dental examination. Finally, the results have also confirmed that the association of the MCNPX code and the MAX and FAX phantoms is very useful in dosimetric studies on radiographic examinations of female and male patients. (author)

  13. Accuracy of cone beam computed tomography, intraoral radiography, and periodontal probing for periodontal bone defects measurement

    Directory of Open Access Journals (Sweden)

    Eskandarlo A

    2011-02-01

    Full Text Available "nBackground and Aims: Cone beam computed tomography (CBCT produces high-quality data about diagnosis and periodontal treatment. To date, there is not enough research regarding periodontal bone measurement using CBCT. The aim of this study was to compare the accuracy of CBCT in measuring periodontal defects to that of intraoral radiography and probing methods."nMaterials and Methods: Two-hundred and eighteen artificial osseous defects (buccal and lingual infrabony, interproximal, horizontal, crater, dehiscence and fenestration defects were created on 13 mandibles of dry skulls. The mandibles were put into a plexiglass box full of water to simulate soft tissue. CBCT images, radiographic images taken with parallel technique and direct measurements using a WHO periodontal probe were recorded and compared to a standard reference (digital caliper. Inter and intra observe consistencies were assessed using Intra class correlation coefficient and pearson correlation."nResults: Inter and intra observer consistencies were high for CBCT and probing methods (ICC- Intra class correlation coefficient>88%, but moderate for intraoral radiography (ICC-Intra class correlation coefficient > 54%. There were not any significant differences between observers for all techniques (P>0/05. According to paired T-test analysis, mean difference for CBCT technique (0.01 mm was lower than that for probing (0.04 mm and radiography (0.62 mm. CBCT was able to measure all kinds of lesions, but radiography could not measure defects in the buccal and lingual sites."nConclusion: All three modalities are useful for identifying periodontal defects. Compared to probing and radiography, the CBCT technique has the most accuracy in measuring periodontal defects.

  14. Acute Bilateral Superior Branch Vestibular Neuropathy

    Directory of Open Access Journals (Sweden)

    Dario A. Yacovino

    2018-05-01

    Full Text Available The rapid onset of a bilateral vestibular hypofunction (BVH is often attributed to vestibular ototoxicity. However, without any prior exposure to ototoxins, the idiopathic form of BVH is most common. Although sequential bilateral vestibular neuritis (VN is described as a cause of BVH, clinical evidence for simultaneous and acute onset bilateral VN is unknown. We describe a patient with an acute onset of severe gait ataxia and oscillopsia with features compatible with acute BVH putatively due to a bilateral VN, which we serially evaluated with clinical and laboratory vestibular function testing over the course of 1 year. Initially, bilateral superior and horizontal semicircular canals and bilateral utricles were impaired, consistent with damage to both superior branches of each vestibular nerve. Hearing was spared. Only modest results were obtained following 6 months of vestibular rehabilitation. At a 1-year follow-up, only the utricular function of one side recovered. This case is the first evidence supporting an acute presentation of bilateral VN as a cause for BVH, which would not have been observed without critical assessment of each of the 10 vestibular end organs.

  15. Bilateral optic neuropathy in acute cryptococcal meningitis

    Institute of Scientific and Technical Information of China (English)

    Qi Zhe Ngoo; Li Min Evelyn Tai; Wan Hazabbah Wan Hitam; John Tharakan

    2016-01-01

    We reported a case of cryptococcal meningitis presenting with bilateral optic neuropathy in an immunocompetent patient. A 64-year-old Malay gentleman with no medical comorbidities presented with acute bilateral blurring of vision for a week, which was associated with generalised throbbing headache and low grade fever. He also had som-nolence and altered consciousness. Visual acuity in both eyes was no perception of light with poor pupillary reflexes. Extraocular muscle movements were normal. Anterior segments were unremarkable bilaterally. Fundoscopy revealed bilateral optic disc swelling. CT scan of the brain showed multifocal infarct, but no meningeal enhancement or mass. Cerebrospinal fluid opening pressure was normal, while its culture grew Cryptococcus neoformans. A diagnosis of cryptococcal meningitis with bilateral optic neuropathy was made. Patient was treated with a six-week course of intravenous flu-conazole and started concomitantly on a fortnight's course of intravenous amphotericin B. After that, his general condition improved, but there was still no improvement in his visual acuity. On reviewing at two months post-initiation of treatment, fundi showed bilateral optic atrophy. Bilateral optic neuropathy secondary to cryptococcal meningitis was rare. The prognosis was guarded due to the sequelae of optic atrophy. Anti-fungal medication alone may not be sufficient to manage this condition. However, evidence for other treatment modalities is still lacking and further clinical studies are required.

  16. Bilateral, independent juvenile nasopharyngeal angiofibroma: case report.

    Science.gov (United States)

    Mørkenborg, M-L; Frendø, M; Stavngaard, T; Von Buchwald, C

    2015-10-01

    Juvenile nasopharyngeal angiofibroma is a benign, vascular tumour that primarily occurs in adolescent males. Despite its benign nature, aggressive growth patterns can cause potential life-threatening complications. Juvenile nasopharyngeal angiofibroma is normally unilateral, originating from the sphenopalatine artery, but bilateral symptoms can occur if a large tumour extends to the contralateral side of the nasopharynx. This paper presents the first reported case of true bilateral extensive juvenile nasopharyngeal angiofibroma involving clinically challenging pre-surgical planning and surgical strategy. A 21-year-old male presented with increasing bilateral nasal obstruction and discharge. Examination revealed tumours bilaterally and imaging demonstrated non-contiguous tumours. Pre-operative angiography showed strictly ipsilateral vascular supplies requiring bilateral embolisation. Radical removal performed as one-step, computer-assisted functional endoscopic sinus surgery was performed. The follow-up period was uncomplicated. This case illustrates the importance of suspecting bilateral juvenile nasopharyngeal angiofibroma in patients presenting with bilateral symptoms. Our management, including successful pre-operative planning, enabled one-step total removal of both tumours and rapid patient recovery.

  17. Fibromuscular Dysplasia Presenting with Bilateral Renal Infarction

    International Nuclear Information System (INIS)

    Doody, O.; Adam, W. R.; Foley, P. T.; Lyon, S. M.

    2009-01-01

    Fibromuscular dysplasia (FMD) describes a group of conditions which cause nonatheromatous arterial stenoses, most commonly of the renal and carotid arteries, typically in young women. We report a rare case of bilateral segmental renal infarction secondary to FMD in a young male patient. His initial presentation with loin pain and pyrexia resulted in a delay in the definitive diagnosis of FMD. He was successfully treated with bilateral balloon angioplasty. The delayed diagnosis in this patient until the condition had progressed to bilateral renal infarcts highlights the need for prompt investigation and diagnosis of suspected cases of FMD.

  18. A longitudinal study of the bilateral benefit in children with bilateral cochlear implants.

    Science.gov (United States)

    Asp, Filip; Mäki-Torkko, Elina; Karltorp, Eva; Harder, Henrik; Hergils, Leif; Eskilsson, Gunnar; Stenfelt, Stefan

    2015-02-01

    To study the development of the bilateral benefit in children using bilateral cochlear implants by measurements of speech recognition and sound localization. Bilateral and unilateral speech recognition in quiet, in multi-source noise, and horizontal sound localization was measured at three occasions during a two-year period, without controlling for age or implant experience. Longitudinal and cross-sectional analyses were performed. Results were compared to cross-sectional data from children with normal hearing. Seventy-eight children aged 5.1-11.9 years, with a mean bilateral cochlear implant experience of 3.3 years and a mean age of 7.8 years, at inclusion in the study. Thirty children with normal hearing aged 4.8-9.0 years provided normative data. For children with cochlear implants, bilateral and unilateral speech recognition in quiet was comparable whereas a bilateral benefit for speech recognition in noise and sound localization was found at all three test occasions. Absolute performance was lower than in children with normal hearing. Early bilateral implantation facilitated sound localization. A bilateral benefit for speech recognition in noise and sound localization continues to exist over time for children with bilateral cochlear implants, but no relative improvement is found after three years of bilateral cochlear implant experience.

  19. Los incentivos para la guerra bilateral: un caso polar

    Directory of Open Access Journals (Sweden)

    Raffo Leonardo

    2008-12-01

    Full Text Available En este trabajo se pretende construir las bases de lo que puede denominarse una teoría económica de la guerra bilateral, esto es, una teoría en la que se elucidan las interconexiones existentes entre el comercio y la guerra entre pares de países. Se demuestra, en un juego en dos etapas con información completa y pagos endógenos, que las propensiones de los países hacia la guerra o hacia la paz, dependen de las asimetrías existentes en la distribución de la demanda y de los recursos. Los equilibrios
    asimétricos de Nash revelan que bajo los supuestos del modelo “la guerra” constituye el único equilibrio posible.

  20. A case of bilateral tubal pregnancy

    Directory of Open Access Journals (Sweden)

    Ayano Funamizu

    2017-11-01

    Full Text Available Bilateral tubal pregnancy is very rare and occurs in only 1 out of every 200,000 spontaneous pregnancies. In this case, a 29-year-old woman with a history of primary infertility underwent treatment with human menopausal gonadotropin (hMG-human chorionic gonadotropin (hCG, and became pregnant. A gestational sac (GS was not detected in the uterus and transvaginal ultrasonography (USG revealed GS with fetal heartbeat in the left adnexa at 7 weeks and 6 days of gestation. The patient underwent laparoscopic surgery and ultimately, bilateral tubal pregnancy was diagnosed. Consequently, bilateral fallopian tube resection was performed. Afterwards, she conceived by assisted reproductive technology (ART and delivered vaginally. This case suggests that even if a GS is found in one fallopian tube by USG, it is important to evaluate the other fallopian tube carefully. Keywords: bilateral tubal pregnancy, ectopic pregnancy, human menopausal gonadotropin, laparoscopy

  1. Bilateral nasolabial cysts associated with recurrent dacryocystitis.

    Science.gov (United States)

    Kyrmizakis, Dionysios E; Lachanas, Vassilios A; Benakis, Antonios A; Velegrakis, George A; Aslanides, Ioannis M

    2005-05-01

    Nasolabial cysts are rare, nonodontogenic, soft-tissue, developmental cysts occurring inferior to the nasal alar region. They are thought to arise from remnants of the nasolacrimal ducts and they are frequently asymptomatic. We report a rare case of bilateral nasolabial cysts accompanied by bilateral chronic dacryocystitis. A 48-year-old woman suffering from bilateral chronic dacryocystitis was referred to our department for endonasal dacryocystorhinostomy. She had undergone external dacryocystorhinostomy on the left side a few years earlier. Physical examination and computed tomography scan revealed nasolabial cysts bilaterally inferior to the nasal alar region. The cysts were removed via a sublabial approach and endoscopic dacryocystorhinostomy was performed on the right side. Ten months after surgery, the patient was asymptomatic. There may be a correlation, due to embryological reasons, between the presence of nasolabial cysts and the presence of chronic dacryocystitis. Both can be corrected surgically, under the same anaesthesia, without visible scar formation.

  2. THE EUROPEAN UNION’S BILATERAL APPROACH

    Directory of Open Access Journals (Sweden)

    Ludmila BORTA

    2014-12-01

    Full Text Available The EU is a world economic power and a major trading partner for most countries. All the time, this region has been interested and has acted towards a free and fair trade. The decrease and even the elimination of tariff and non-tariff barriers in the world trade are among the main objectives of the EU strategy for international trade. At the moment, the elusive outcome of the WTO Doha Round has led to the proliferation of bilateral trade agreements worldwide. Although the EU remains committed to further development of the multilateral trading system, however, the EU still has appealed also to the development of bilateral trade relations. The aim of this paper is to illustrate the current bilateral dimension of the common commercial policy of the EU. In conclusion, to describe this bilateral approach of the EU we are using one word, namely “diversity”.

  3. FLOWING BILATERAL FILTER: DEFINITION AND IMPLEMENTATIONS

    Directory of Open Access Journals (Sweden)

    Maxime Moreaud

    2015-06-01

    Full Text Available The bilateral filter plays a key role in image processing applications due to its intuitive parameterization and its high quality filter result, smoothing homogeneous regions while preserving the edges of the objects. Considering the image as a topological relief, seeing pixel intensities as peaks and valleys, we introduce a way to control the tonal weighting coefficients, the flowing bilateral filter, reducing "halo" artifacts typically produced by the regular bilateral filter around a large peak surrounded by two valleys of lower values. In this paper we propose to investigate exact and approximated versions of CPU and parallel GPU (Graphical Processing Unit based implementations of the regular and flowing bilateral filter using the NVidia CUDA API. Fast implementations of these filters are important for the processing of large 3D volumes up to several GB acquired by x-ray or electron tomography.

  4. EXERTIONAL RHABDOMYOLYSIS OF THE BILATERAL ADDUCTOR MAGNUS

    Directory of Open Access Journals (Sweden)

    Tolga Saka

    2007-12-01

    Full Text Available We present a case study of a person (63 year-old man, who has been using statins for 18 years, with rhabdomyolysis of the bilateral adductor muscles associated with strenuous and prolonged eccentric exercises (hiking in a hot environment. Clinical examination showed predominantly on the right side muscle swelling and palpational pain of the bilateral adductor muscle groups and bilateral tibial edema. His serum creatine kinase (CK level was 12218 IU/L. T2-weighted magnetic resonance (MR images showed a high signal intensity in the bilateral adductor muscles of the hip. The patient did not develop complications and returned to his previous performance level in 30 days following adequate hydration and resting of the affected muscles. Strenuous eccentric exercise should be avoided during the course of statin use and clinicians should be aware of present observations when considering the significance of acute CK elevations in patients on statin treatment

  5. Bilateral Tubal Pregnancy without Known Risk Factor

    Directory of Open Access Journals (Sweden)

    Hyacinthe Zamané

    2017-01-01

    Full Text Available Spontaneous bilateral ectopic gestation is very rare. The authors report a case diagnosed and taken care of at Yalgado Ouedraogo Teaching Hospital, Ouagadougou. It was a 30-year-old patient with no known pathological history. She had presented at the obstetric emergencies with a state of hypovolemic shock by haemoperitoneum with digestive disorders, pelvic pain, vaginal bleeding, and a mention of delayed menstruation. The ultrasound coupled with the urinary immunological pregnancy test confirmed the diagnosis of ruptured ectopic pregnancy and a bilateral form was suspected. A laparotomy in emergency confirmed the diagnosis of bilateral ectopic gestation with a right ampullary unruptured pregnancy and a left isthmic ruptured gestation. A bilateral salpingectomy was performed and counseling was made for the use of medical help of procreation in case of future need of pregnancy.

  6. Validity of Intraoral Scans Compared with Plaster Models: An In-Vivo Comparison of Dental Measurements and 3D Surface Analysis.

    Directory of Open Access Journals (Sweden)

    Fan Zhang

    Full Text Available Dental measurements have been commonly taken from plaster dental models obtained from alginate impressions can. Through the use of an intraoral scanner, digital impressions now acquire the information directly from the mouth. The purpose of this study was to determine the validity of the intraoral scans compared to plaster models.Two types of dental models (intraoral scan and plaster model of 20 subjects were included in this study. The subjects had impressions taken of their teeth and made as plaster model. In addition, their mouths were scanned with the intraoral scanner and the scans were converted into digital models. Eight transverse and 16 anteroposterior measurements, 24 tooth heights and widths were recorded on the plaster models with a digital caliper and on the intraoral scan with 3D reverse engineering software. For 3D surface analysis, the two models were superimposed by using best-fit algorithm. The average differences between the two models at all points on the surfaces were computed. Paired t-test and Bland-Altman plot were used to determine the validity of measurements from the intraoral scan compared to those from the plaster model.There were no significant differences between the plaster models and intraoral scans, except for one measurement of lower intermolar width. The Bland-Altman plots of all measurements showed that differences between the two models were within the limits of agreement. The average surface difference between the two models was within 0.10 mm.The results of the present study indicate that the intraoral scans are clinically acceptable for diagnosis and treatment planning in dentistry and can be used in place of plaster models.

  7. Validity of Intraoral Scans Compared with Plaster Models: An In-Vivo Comparison of Dental Measurements and 3D Surface Analysis

    Science.gov (United States)

    2016-01-01

    Purpose Dental measurements have been commonly taken from plaster dental models obtained from alginate impressions can. Through the use of an intraoral scanner, digital impressions now acquire the information directly from the mouth. The purpose of this study was to determine the validity of the intraoral scans compared to plaster models. Materials and Methods Two types of dental models (intraoral scan and plaster model) of 20 subjects were included in this study. The subjects had impressions taken of their teeth and made as plaster model. In addition, their mouths were scanned with the intraoral scanner and the scans were converted into digital models. Eight transverse and 16 anteroposterior measurements, 24 tooth heights and widths were recorded on the plaster models with a digital caliper and on the intraoral scan with 3D reverse engineering software. For 3D surface analysis, the two models were superimposed by using best-fit algorithm. The average differences between the two models at all points on the surfaces were computed. Paired t-test and Bland-Altman plot were used to determine the validity of measurements from the intraoral scan compared to those from the plaster model. Results There were no significant differences between the plaster models and intraoral scans, except for one measurement of lower intermolar width. The Bland-Altman plots of all measurements showed that differences between the two models were within the limits of agreement. The average surface difference between the two models was within 0.10 mm. Conclusions The results of the present study indicate that the intraoral scans are clinically acceptable for diagnosis and treatment planning in dentistry and can be used in place of plaster models. PMID:27304976

  8. Anomalías dentó maxilares y factores asociados en niños con parálisis cerebral

    OpenAIRE

    BARRIONUEVO N, LIVIA; SOLÍS F, FRESIA

    2008-01-01

    Introducción: Los pacientes con parálisis cerebral atendidos en el Instituto de Rehabilitación Infantil de Santiago, presentan mordidas abiertas y disfunción oral. Objetivos: Determinar anomalías dentó maxilares y relacionarlas con diagnóstico de parálisis cerebral y factores asociados de alimentación, respiración y hábitos parafuncionales. Pacientes y Método: Estudio descriptivo transversal, que incluyó revisión de fichas clínicas 2005-2006, examen extra e intraoral y encuesta a los padres d...

  9. Bilateral calcaneal epiphysiolysis in a dog.

    Science.gov (United States)

    Font, J; Pèlach, M; Font, C; Cairo, J

    2013-01-01

    A case of bilateral calcaneal epiphysiolysis in a six-month-old female Dobermann Pinscher is described in this report. The absence of a traumatic event and the clinical, radiographic and histopathological abnormalities led us to the diagnosis of simultaneous bilateral epiphysiolysis of the calcaneus. A tension band and a type II transarticular external fixator were placed. The clinical signs were resolved only temporarily because of the gravity of the bone changes.

  10. Recurrent Bilateral Breast Abscesses after Sternotomy

    Directory of Open Access Journals (Sweden)

    Hamza Cinar

    2012-01-01

    Full Text Available Median sternotomy is the most commonly used incision in cardiothoracic procedures. Development of breast abscess after sternotomy is a very rare situation. We present a case of sternal wound infection with recurrent bilateral breast abscess after sternotomy. Our case is the first and only case in the literature due to the presence of sternal wound infection with recurrent bilateral breast abscess after sternotomy.

  11. Cutaneous metastasis of bilateral renal cell carcinoma.

    Science.gov (United States)

    Abbasi, Fariba; Alizadeh, Mansur; Noroozinia, Farahnaz; Moradi, Amin

    2013-01-01

    Renal cell carcinoma (RCC) is a malignant lethal tumour with high potential of metastasis. However, metastasis from RCC to the skin is much less common. It is virtually a sign of poor prognosis. We represent a 42 years old man with bilateral RCC of clear cell type followed by metastasis to the scalp one month later. In this case the relatively young age of the patient, bilaterality of RCC and occurance of skin metastasis in the absence of recurrent kidney tumour are interesting.

  12. Bilateral anophthalmia with septo-optic dysplasia

    OpenAIRE

    Jana, Manisha; Sharma, Sanjay

    2010-01-01

    Bilateral anophthalmia is a rare entity and association with septo-optic dysplasia is an even rare condition. The condition is characterized by absent eyeballs in the presence of eyelids, conjunctiva or lacrimal apparatus. Though anophthalmia can be diagnosed clinically, imaging plays a crucial role in delineating the associated anomalies. In addition, often clinical anophthalmia may prove to be severe microphthalmia on imaging. We describe the imaging findings in an infant with bilateral ano...

  13. Bilateral anophthalmia with septo-optic dysplasia

    Directory of Open Access Journals (Sweden)

    Manisha Jana

    2010-01-01

    Full Text Available Bilateral anophthalmia is a rare entity and association with septo-optic dysplasia is an even rare condition. The condition is characterized by absent eyeballs in the presence of eyelids, conjunctiva or lacrimal apparatus. Though anophthalmia can be diagnosed clinically, imaging plays a crucial role in delineating the associated anomalies. In addition, often clinical anophthalmia may prove to be severe microphthalmia on imaging. We describe the imaging findings in an infant with bilateral anophthalmia and septo-optic dysplasia.

  14. Bilateral cerebellopontine arachnoid cyst: A rare entity.

    Science.gov (United States)

    Sharma, Anand; Sharma, Achal; Mittal, Radhey S; Gandhi, Ashok

    2015-01-01

    Bilateral cerebellopontine angle (CPA) arachnoid cysts (ACs) are very rare: only one case is reported in literature. Pathogenesis of those cysts is unknown; they are thought to be congenital. The presenting symptoms of CPA AC are frequently nonspecific or otological. The management of ACs of the CPA is controversial. We are reporting two cases of bilateral CPA AC with their pathophysiology and review of literature.

  15. BILATERAL CHOROIDAL EXCAVATION IN JUVENILE LOCALIZED SCLERODERMA.

    Science.gov (United States)

    Franklin, Mackenzie L; Day, Shelley

    2018-01-01

    To describe a case of bilateral choroidal excavation in a patient with juvenile localized scleroderma. Case report. An asymptomatic 12-year-old boy with localized scleroderma presented for examination and was found to have bilateral areas of choroidal excavation temporal to the fovea. Previous reports of ocular complications of localized scleroderma have primarily described adnexal and anterior segment changes. This is the second report of choroidal changes in a patient with localized scleroderma, and the first in a pediatric patient.

  16. Bilateral acute retinal necrosis associated with bilateral uveal effusion in an immunocompetent patient: A challenging association

    Directory of Open Access Journals (Sweden)

    S Bala Murugan

    2018-01-01

    Full Text Available Bilateral uveal effusion syndrome associated with bilateral acute retinal necrosis is a diagnostic and therapeutic challenge. A 52 year old man presented with bilateral angle closure with choroidal detachment. With restricted fundus view, parenteral steroid was started. During close follow up bilateral discrete areas of peripheral retinitis were noted. Parenteral steroids were promptly stopped and parenteral antivirals with oral steroids were continued. It showed healing response with nil recurrences till last follow up. Aggressive treatment of bilateral uveal effusion with parenteral steroids can cause progression of bilateral acute retinal necrosis leading to phthisis bulbi. However early diagnosis, prompt intervention and close follow up are the key elements to therapeutic success even during diagnostic surprises and avoid costly mistakes.

  17. A SECOND CASE OF BILATERAL RHEGMATOGENOUS RETINAL DETACHMENTS REPAIRED WITH SIMULTANEOUS BILATERAL PNEUMATIC RETINOPEXY.

    Science.gov (United States)

    Rubin, Uriel; De Jager, Cornelis; Zakour, Moayed; Gonder, J Thomas

    2017-01-01

    To present a case of a patient with simultaneous bilateral retinal detachments treated successfully with bilateral pneumatic retinopexy. Case report. This is a case of an otherwise healthy 49-year-old woman with no remarkable ocular history that presented with simultaneous phakic superior bilateral rhegmatogenous retinal detachments. Treatment on the day of presentation included laser retinopexy of the inferior lattice degeneration in the left eye and bilateral intravitreal injection of 0.4 cc of 100% C3F8 gas preceded by topical anesthesia. After 48 hours, both retinas were completely reattached, and bilateral laser retinopexy was performed to the superior tears. After a review of the literature, the authors could find only two reported cases of simultaneous bilateral retinal detachments treated successfully with pneumatic retinopexy. This is not only a cost-effective procedure but also allows treatment when there is no immediate operating room availability or a when a quick referral for surgery is not possible.

  18. Bilateral Keratectasia 34 Years after Corneal Transplant

    Directory of Open Access Journals (Sweden)

    Xavier Valldeperas

    2010-07-01

    Full Text Available We report the clinical findings of a patient with severe bilateral keratectasia 34 years after a penetrating keratoplasty (PK in both eyes. An otherwise healthy 67-year-old man complained of deterioration of the eyesight in both eyes over the last 6 months. The patient was diagnosed with bilateral keratoconus at the age of 32 years, and he underwent a bilateral PK. At presentation, visual acuity was 20/200 in the right eye and light perception in the left eye. A Pentacam pachymetric map revealed a central pachymetry of 720 µm in the right eye and of 710 µm in the left eye, as well as an average paracentral pachymetry of 436 and 270 µm in the 9-mm zone in the right and the left eye, respectively. Corneal topography revealed bilateral irregular and asymmetric bowing with generalized steepening and high corneal power. We describe a case of bilateral keratectasia 34 years after PK in a patient who was originally diagnosed with bilateral keratoconus.

  19. Bilateral tension pneumothorax related to acupuncture.

    Science.gov (United States)

    Tagami, Rumi; Moriya, Takashi; Kinoshita, Kosaku; Tanjoh, Katsuhisa

    2013-06-01

    We report on a patient with a rare case of bilateral tension pneumothorax that occurred after acupuncture. A 69-year-old large-bodied man, who otherwise had no risk factors for spontaneous pneumothorax, presented with chest pressure, cold sweats and shortness of breath. Immediately after bilateral pneumothorax had been identified on a chest radiograph in the emergency room, his blood pressure and percutaneous oxygen saturation suddenly decreased to 78 mm Hg and 86%, respectively. We confirmed deterioration in his cardiopulmonary status and diagnosed bilateral tension pneumothorax. We punctured his chest bilaterally and inserted chest tubes for drainage. His vital signs promptly recovered. After the bilateral puncture and drainage, we learnt that he had been treated with acupuncture on his upper back. We finally diagnosed a bilateral tension pneumothorax based on the symptoms that appeared 8 h after the acupuncture. Because the patient had no risk factors for spontaneous pneumothorax, no alternative diagnosis was proposed. We recommend that patients receiving acupuncture around the chest wall must be adequately informed of the possibility of complications and expected symptoms, as a definitive diagnosis can be difficult without complete information.

  20. MODERN VIEWS ON BILATERAL BREAST CANCER

    Directory of Open Access Journals (Sweden)

    Ye. A. Fesik

    2014-01-01

    Full Text Available Presented modern literature data on the features of the pathogenesis, course, clinical and morphological expression and tumor characteristics, parameters and nodal metastasis of hematogenous bilateral breast cancer. Highlight the results of domestic and foreign studies in recent years to determine the prognostic factors and recurrence of synchronous and metachronous bilateral breast cancer. It was revealed that the frequency of bilateral breast tumor lesions varies widely, ranging from 0.1 to 20%, with metachronous tumors recorded significantly higher (69.6% than the synchronous (22.7%. The probability of occurrence of metachronous breast cancer is higher in women with a family history, as well as if they have a gene mutation BRCA-1. Found that the most common histological type of breast tumor with bilateral lesions is invasive ductal. However, the incidence of invasive lobular cancer and non-invasive lobular cancer is slightly higher among synchronous bilateral cancer compared with unilateral disease. Studies have shown that in a double-sided synchronous breast cancer tumor, as a rule, has a lower degree of differentiation, and the higher the expression level of estrogen receptors and progesterone receptors. Relevance of the issue because the identification of patterns in the study of lymphatic and hematogenous features bilateral metastasis of mammary tumors provides a basis for speculation about the differences in the progression of neoplastic disease in these groups and is a cause for further detailed research in this area to identify and evaluate the prognosis and also the choice of tactics of such patients.

  1. Effect of intra-oral aging on t→m phase transformation, microstructure, and mechanical properties of Y-TZP dental ceramics.

    Science.gov (United States)

    Miragaya, Luciana Meireles; Guimarães, Renato Bastos; Souza, Rodrigo Othávio de Assunção E; Santos Botelho, Glauco Dos; Antunes Guimarães, José Guilherme; da Silva, Eduardo Moreira

    2017-08-01

    The aim of the present study was to evaluate the influence of intra-oral aging on the tetragonal-to-monoclinic (t→m) phase transformation of two Y-TZP dental ceramics - Lava Frame (Frame) and Lava Plus (Plus) - and determine the impact of this response on their microstructures and mechanical properties: flexural strength, Young's modulus, microhardness and fracture toughness. Standardized ceramic specimens were analyzed by X-ray diffraction (XRD), scanning electron microscopy (SEM) and atomic force microscopy (AFM). After the baseline analysis, the specimens were attached to personalized intra-oral resin appliances and exposed to the oral cavity of 20 subjects for 60 days and then analyzed again. Specimens produced for mechanical properties evaluation were also analyzed before and after the 60-day intra-oral aging. The data were analyzed using two-way ANOVA and Tukey HSD's post hoc test (α=0.05). Weibull analysis was used to evaluate the strength reliability. Both Y-TZP ceramics suffered t→m phase transformation after 60-day intra-oral aging (Plus=4.7%/Frame=7.7%). SEM and AFM analyses showed dislodgement of ZrO 2 grains and a significant increase in roughness after intra-oral aging for both ceramics. Both Y-TZP ceramics suffered a decrease on flexural strength, Young's modulus and fracture toughness after intra-oral aging (pdental ceramics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Pleomorphic adenoma of the accessory parotid gland: case report and reappraisal of intraoral extracapsular dissection for management.

    Science.gov (United States)

    Tsegga, Tibebu M; Britt, Jennifer D; Ellwanger, Aragon R

    2015-03-01

    Pleomorphic adenoma is the most common tumor of the major and minor salivary glands. Rarely is it found evolving from an ectopic location of major salivary glandular tissue in the mid cheek. A healthy 56-year-old woman presented to our institution with a 20-year duration of a slowly growing right cheek soft tissue mass that was causing facial asymmetry. No significant functional or neurosensory dysfunction was appreciated. Radiologic examination showed a heterogeneous, hyperintense, well-delineated mass within the region of the right buccal fat pad. Fine-needle aspiration biopsy showed benign salivary gland elements consistent with pleomorphic adenoma. The decision was made to perform intraoral extracapsular dissection for removal. Discussion of the clinical assessment and magnetic resonance imaging evaluation with an emphasis on intraoral extracapsular dissection for definitive surgical therapy of longstanding benign salivary gland tumors is emphasized. Published by Elsevier Inc.

  3. The correlationship between mandibular radiomorphometric indices in panorama and bone mineral density in Cu-equivalent image of intraoral film

    International Nuclear Information System (INIS)

    Kim, Jae Duk

    2003-01-01

    To determine whether the mandibular radiomorphometric indices in panoramic radiography are correlated with the bone mineral density of Cu-equivalent images in intraoral film. The bone mineral density (BMD) of the mandibular premolar area was measured in the Cu-equivalent image of intraoral film. The Panoramic Mandibular Index (PMI) and Mandibular Cortical Width (MCW) were measured in panoramic radiographs of six dry mandibles, and the Pearson correlation between PMI, MCW, and BMD were tested. There were no significant correlations between PMI and BMD (r=0.280), nor between MCW and BMD (r=0.237). The results show that PMI and MCW were poor diagnostic indicators of mandibular BMD in the six dry mandibles used in this study. The correlationship between the mandibular radiomorphometric indices (PMI and MCW) and mandibular BMD needs to be researched further using large in vivo patient samples.

  4. Intraoral 3D Scanning or Dental Impressions for the Assessment of Dental Arch Relationships in Cleft Care: Which is Superior?

    Science.gov (United States)

    Chalmers, E V; McIntyre, G T; Wang, W; Gillgrass, T; Martin, C B; Mossey, P A

    2016-09-01

    This study was undertaken to evaluate intraoral 3D scans for assessing dental arch relationships and obtain patient/parent perceptions of impressions and intraoral 3D scanning. Forty-three subjects with nonsyndromic unilateral cleft lip and palate (UCLP) had impressions taken for plaster models. These and the teeth were scanned using the R700 Orthodontic Study Model Scanner and Trios® Digital Impressions Scanner (3Shape A/S, Copenhagen, Denmark) to create indirect and direct digital models. All model formats were scored by three observers on two occasions using the GOSLON and modified Huddart Bodenham (MHB) indices. Participants and parents scored their perceptions of impressions and scanning from 1 (very good) to 5 (very bad). Intra- and interexaminer reliability were tested using GOSLON and MHB data (Cronbach's Alpha >0.9). Bland and Altman plots were created for MHB data, with each model medium (one-sample t tests, P 0.9) were good for all formats with the direct digital models having the lowest interexaminer differences. Participants had higher ratings for scanning comfort (84.8%) than impressions (44.2%) (P impressions (51.2%) (P > .05). None disliked scanning, but 16.3% disliked impressions. Data for parents and children positively correlated (P 3D scans was superior to indirect digital and to plaster models; Subjects with UCLP preferred intra-oral 3D scanning to dental impressions, mirrored by parents/carers; This study supports the replacement of conventional impressions with intra-oral 3D scans in longitudinal evaluations of the outcomes of cleft care.

  5. Standing intraoral extractions of cheek teeth aided by partial crown removal in 165 horses (2010-2016).

    Science.gov (United States)

    Rice, M K; Henry, T J

    2018-01-01

    Diseased cheek teeth in horses often require invasive extraction techniques that carry a high rate of complications. Techniques and instrumentation were developed to perform partial crown removal to aid standing intraoral extraction of diseased cheek teeth in horses. To analyse success rates and post-surgical complications in horses undergoing cheek teeth extraction assisted by partial crown removal. Retrospective cohort study. This study included 165 horses with 194 diseased cheek teeth that were extracted orally assisted by partial crown removal between 2010 and 2016. Medical records were analysed, including case details, obtained radiographs, surgical reports and follow-up information. Follow-up information (≥2 months) was obtained for 151 horses (91.5%). There were 95 horses examined post-operatively by the authors and, 16 horses by the referring veterinarian; in 40 horses, post-operative follow up was obtained by informal telephone interviews with the owner. Successful standing intraoral extraction of cheek teeth was obtained in 164/165 horses (99.4%). Twenty-five of these horses (15.2%) required additional intraoral extraction methods to complete the extraction, including minimally invasive transbuccal approach (n = 21) and tooth sectioning (n = 4). There was one (0.6%) horse with intraoral extraction failure that required standing repulsion to complete the extraction. The intraoperative complication of fractured root tips occurred in 11/165 horses (6.7%). Post-operative complications occurred in 6/165 horses (3.6%), including alveolar sequestra (n = 4), mild delay of alveolar healing at 2 months (n = 1), and development of a persistent draining tract secondary to a retained root tip (n = 1). Specialised instrumentation and additional training in the technique are recommended to perform partial crown removal in horses. Horses with cheek teeth extraction by partial crown removal have an excellent prognosis for a positive outcome. The term partial coronectomy

  6. On the tip of the tongue: learning typing and pointing with an intra-oral computer interface.

    Science.gov (United States)

    Caltenco, Héctor A; Breidegard, Björn; Struijk, Lotte N S Andreasen

    2014-07-01

    To evaluate typing and pointing performance and improvement over time of four able-bodied participants using an intra-oral tongue-computer interface for computer control. A physically disabled individual may lack the ability to efficiently control standard computer input devices. There have been several efforts to produce and evaluate interfaces that provide individuals with physical disabilities the possibility to control personal computers. Training with the intra-oral tongue-computer interface was performed by playing games over 18 sessions. Skill improvement was measured through typing and pointing exercises at the end of each training session. Typing throughput improved from averages of 2.36 to 5.43 correct words per minute. Pointing throughput improved from averages of 0.47 to 0.85 bits/s. Target tracking performance, measured as relative time on target, improved from averages of 36% to 47%. Path following throughput improved from averages of 0.31 to 0.83 bits/s and decreased to 0.53 bits/s with more difficult tasks. Learning curves support the notion that the tongue can rapidly learn novel motor tasks. Typing and pointing performance of the tongue-computer interface is comparable to performances of other proficient assistive devices, which makes the tongue a feasible input organ for computer control. Intra-oral computer interfaces could provide individuals with severe upper-limb mobility impairments the opportunity to control computers and automatic equipment. Typing and pointing performance of the tongue-computer interface is comparable to performances of other proficient assistive devices, but does not cause fatigue easily and might be invisible to other people, which is highly prioritized by assistive device users. Combination of visual and auditory feedback is vital for a good performance of an intra-oral computer interface and helps to reduce involuntary or erroneous activations.

  7. Three-Dimensional Implant Positioning with a Piezosurgery Implant Site Preparation Technique and an Intraoral Surgical Navigation System: Case Report.

    Science.gov (United States)

    Pellegrino, Gerardo; Taraschi, Valerio; Vercellotti, Tomaso; Ben-Nissan, Besim; Marchetti, Claudio

    This case report describes new implant site preparation techniques joining the benefits of using an intraoral navigation system to optimize three-dimensional implant site positioning in combination with an ultrasonic osteotomy. A report of five patients is presented, and the implant positions as planned in the navigation software with the postoperative scan image were compared. The preliminary results are useful, although further clinical studies with larger populations are needed to confirm these findings.

  8. Identification of the Procedural Accidents During Root Canal Preparation Using Digital Intraoral Radiography and Cone Beam Computed Tomography

    OpenAIRE

    Csinszka K.-Ivácson A.-; Maria Monea Adriana; Monica Monea; Mihai Pop; Angela Borda

    2016-01-01

    Crown or root perforation, ledge formation, fractured instruments and perforation of the roots are the most important accidents which appear during endodontic therapy. Our objective was to evaluate the value of digital intraoral periapical radiographs compared to cone beam computed tomography images (CBCT) used to diagnose some procedural accidents. Material and methods: Eleven extracted molars were used in this study. A total of 18 perforations and 13 ledges were created artifically and 10 i...

  9. Intra-oral orthosis vs amitriptyline in chronic tension-type headache: a clinical and laser evoked potentials study

    Directory of Open Access Journals (Sweden)

    Sardaro Michele

    2006-05-01

    Full Text Available Abstract Background In the present study, we examined clinical and laser-evoked potentials (LEP features in two groups of chronic tension-type headache (CTTH patients treated with two different approaches: intra-oral appliance of prosthesis, aiming to reduce muscular tenderness, and 10 mg daily amitriptyline. Methods Eighteen patients with diagnosed CTTH participated in this open label, controlled study. A baseline evaluation was performed for clinical features, Total Tenderness Score (TTS and a topographic analysis of LEPs obtained manually and the pericranial points stimulation in all patients vs. healthy subjects. Thereafter, patients were randomly assigned to a two-month treatment by either amitriptyline or intra-oral appliance. Results and discussion Both the intra-oral appliance and amitriptyline significantly reduced headache frequency. The TTS was significantly reduced in the group treated with the appliance. The amplitude of P2 response elicited by stimulation of pericranial zones showed a reduction after amitriptyline treatment. Both therapies were effective in reducing headache severity, the appliance with a prevalent action on the pericranial muscular tenderness, amitriptyline reducing the activity of the central cortical structures subtending pain elaboration Conclusion The results of this study may suggest that in CTTH both the interventions at the peripheral and central levels improve the outcome of headache.

  10. Accuracy of single-abutment digital cast obtained using intraoral and cast scanners.

    Science.gov (United States)

    Lee, Jae-Jun; Jeong, Ii-Do; Park, Jin-Young; Jeon, Jin-Hun; Kim, Ji-Hwan; Kim, Woong-Chul

    2017-02-01

    Scanners are frequently used in the fabrication of dental prostheses. However, the accuracy of these scanners is variable, and little information is available. The purpose of this in vitro study was to compare the accuracy of cast scanners with that of intraoral scanners by using different image impression techniques. A poly(methyl methacrylate) master model was fabricated to replicate a maxillary first molar single-abutment tooth model. The master model was scanned with an accurate engineering scanner to obtain a true value (n=1) and with 2 intraoral scanners (CEREC Bluecam and CEREC Omnicam; n=6 each). The cast scanner scanned the master model and duplicated the dental stone cast from the master model (n=6). The trueness and precision of the data were measured using a 3-dimensional analysis program. The Kruskal-Wallis test was used to compare the different sets of scanning data, followed by a post hoc Mann-Whitney U test with a significance level modified by Bonferroni correction (α/6=.0083). The type 1 error level (α) was set at .05. The trueness value (root mean square: mean ±standard deviation) was 17.5 ±1.8 μm for the Bluecam, 13.8 ±1.4 μm for the Omnicam, 17.4 ±1.7 μm for cast scanner 1, and 12.3 ±0.1 μm for cast scanner 2. The differences between the Bluecam and the cast scanner 1 and between the Omnicam and the cast scanner 2 were not statistically significant (P>.0083), but a statistically significant difference was found between all the other pairs (POmnicam, 9.2 ±1.2 μm for cast scanner 1, and 6.9 ±2.6 μm for cast scanner 2. The differences between Bluecam and Omnicam and between Omnicam and cast scanner 1 were not statistically significant (P>.0083), but there was a statistically significant difference between all the other pairs (POmnicam in video image impression had better trueness than a cast scanner but with a similar level of precision. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by

  11. Neuralgia do trigêmeo bilateral: relato de caso Neuralgia del trigémino bilateral: relato de caso Bilateral trigeminal neuralgia: case report

    Directory of Open Access Journals (Sweden)

    Caio Marcio Barros de Oliveira

    2009-08-01

    ón intensamente dolorosa, caracterizada por brotes de dolor lancinantes y súbitos, del tipo descarga eléctrica, con una duración de pocos segundos a dos minutos y generalmente unilateral. Su incidencia anual es de cerca de 4,3 en 100.000 en la población general, manifestándose bilateralmente en solo un 3% de esos casos. El objetivo de este artículo fue describir un caso raro de neuralgia del trigémino primario bilateral. RELATO DEL CASO: Paciente de 61 años, del estado brasileño de Maranhão, casada, ama de casa, con antecedentes de hipertensión arterial y hace seis años quejándose de dolor intenso en V2-V3 a la izquierda, con una duración de 5 a 10 segundos en la región lateral de la nariz y la mandíbula, con empeoramiento al hablar, masticar y con una reducción de la temperatura. Ya había utilizado clorpromazina (3 mg a cada ocho horas, y carbamazepina (200 mg a cada ocho horas, durante seis meses sin que se le aliviase el dolor. Cuando se le examinó físicamente, presentaba alodinia térmica y mecánica en regiones de V2-V3. Estaba usando gabapentina (1.200 mg al día, con alivio parcial del dolor. Se le aumentó entonces la gabapentina para 1.500 mg al día y se le introdujo la amitriptilina 12,5 mg por la noche. La paciente desarrolló un ligero y esporádico dolor, con una reducción de su intensidad a lo largo de 10 meses de tratamiento, siendo reducida progresivamente la gabapentina para 600 mg al día y mantenida la amitriptilina 12,5 mg al día. Después de un año, empezó a presentar dolor de características similares en la región mandibular a la derecha, y mejoró con el aumento de la gabapentina para 900 mg al día. No presentaba exámenes de tomografía o resonancia magnética de encéfalo alterados. CONCLUSIONES: La carbamazepina es el fármaco de primera elección para el tratamiento de la neuralgia trigeminal, sin embargo la gabapentina ha sido cada vez más utilizada como primera medida farmacológica o en casos refractarios a la terapia

  12. Efecto del Colgajo Desplazado Coronalmente con y sin Bioacondicionamiento Cementario de Myrciaria Dubia (Camu-Camu) en la Posición Gingival Aparente y Real en Pacientes con Recesión Gingival Clase II de Miller de la Clínica Odontológica. UCSM. Arequipa. 2015

    OpenAIRE

    Macedo Reynoso, Percy Antonio

    2017-01-01

    La presente investigación tiene por objeto determinar el efecto del colgajo desplazado coronalmente con y sin bioacondicionamiento cementario de Myrciaria Dubia en la posición gingival aparente y real en pacientes con recesión gingival clase II de Miller. Corresponde a un ensayo clínico, randomizado, por ende prospectivo, longitudinal, comparativo y de campo, de nivel cuasi-experimental. Las variables PGA y PGR han sido estudiadas por observación experimental clínica intraoral, una vez en...

  13. Bilateral agenesis of the anterior cruciate ligament: MRI evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Bedoya, Maria A.; Jaramillo, Diego [The Children' s Hospital of Philadelphia, Radiology Department, Philadelphia, PA (United States); McGraw, Michael H. [Hospitalof theUniversityof Pennsylvania, Divisionof Orthopaedics, Philadelphia, PA (United States); Wells, Lawrence [The Children' s Hospital of Philadelphia, Division of Orthopaedics, Philadelphia, PA (United States)

    2014-09-15

    Bilateral agenesis of the anterior cruciate ligament (ACL) is extremely rare. We describe a 13-year-old girl who presented with bilateral knee pain without history of trauma; she has two family members with knee instability. Magnetic resonance imaging showed bilateral absence of the ACL, and medial posterior horn meniscal tears. Bilateral arthroscopic partial meniscectomy and anterior cruciate ligament reconstruction was performed. (orig.)

  14. Paciente con esquizofrenia tratado con ziprasidona + clozapina

    Directory of Open Access Journals (Sweden)

    Pol Yanguas E.

    2013-05-01

    Full Text Available P es un paciente diagnosticado de esquizofrenia, sigue en un piso tutelado un programa de rehabilitación, está medicado con clozapina 500 mg/día y ziprasidona 280 mg/ día. Padece hipercolesterolemia, tabaquismo y sus hábitos alimenticios no son buenos. La medicación que utiliza desde 2007 hasta ahora se refleja en la tabla 1. El último tratamiento se le introdujo el 7 de agosto de 2012, habiendo presentado un electro cardiograma (ECG normal, pero con ligera taquicardia ventricular y prolactinemia de 44,8 ng/ml (valores normales: 2-18 ng/ml.

  15. Bilateral electric energy contracts: return and risk

    Energy Technology Data Exchange (ETDEWEB)

    Gunn, Laura K.; Silva, Elisa B.; Correia, Paulo B. [State University of Campinas (UNICAMP), SP (Brazil). College of Mechanical Engineering

    2009-07-01

    In Brazil electricity is traded through three segments: the spot market that balances offer and demand, with prices calculated by a cost-based computational model; the regulated market , where prices are settled in public auctions, and the free market for bilateral contracts. As spot and regulated market prices are public information, a seller is able to calculate his opportunity price to trade a bilateral contract in the free market by using the non-arbitrage principle. Thus, the seller searches the price of a bilateral contract in the free market that balances his/her revenues with the value expected in case it were negotiated in the regulated and the spot market. Besides the expected revenue, the seller may also consider the CVaR to measure the risk of her/his bilateral contract in the free market. So this paper develops a binomial lattice approach to price bilateral contracts in the free market, considering the seller's opportunity of negotiations in both regulated and spot markets, and measuring the contract risk directly. (author)

  16. Pathogenesis and prognosis of bilateral thalamic infarction

    International Nuclear Information System (INIS)

    Nakase, Taizen; Ogura, Naoko; Maeda, Tetsuya; Yamazaki, Takashi; Kameda, Tomoaki; Sato, Yuichi; Nagata, Ken

    2008-01-01

    Only a few reports have discussed the detailed clinical symptoms and pathogenesis of bilateral thalamic infarction. The thalamus is composed of different functional nuclei and supplied by vessels containing several variations from the main arteries, leading to difficulty in the precise evaluation of bilateral thalamic infarction. In the present study, we assessed the prognosis of bilateral thalamic infarction based on the distribution of stroke lesions. From among the consecutive ischemic stroke patients admitted to hospital between April 2001 and March 2005, cases of acute bilateral thalamic infarction were selected for this study (n=9; 65.1±13.6 y.o.). The stroke lesions and vascular abnormalities were investigated by magnetic resonance imaging and magnetic resonance angiography on admission. Outcome was evaluated from the modified Rankin scale (mRS) at discharge. Good outcome patients (mRS 0-2; n=5) showed memory disturbance, cognitive impairment and hypersomnia. On the other hand, quadriplegia, oculomotor disturbance and bulbar palsy were observed in the poor outcome patients (mRS≥4; n=4). The critical features of a poor outcome were the age at onset (72.0±15.3 vs. 58.2±11.9 y.o.), inclusion of brainstem lesions and total occlusion of the basilar artery. In conclusion, older age at onset and/or basilar artery occlusion may be critical factors for predicting a poor outcome in bilateral thalamic infarction cases. (author)

  17. Bilateral Testicular Tumors Resulting in Recurrent Cushing Disease After Bilateral Adrenalectomy

    NARCIS (Netherlands)

    Puar, T.; Engels, M.; Herwaarden, A.E. van; Sweep, F.C.; Hulsbergen-van de Kaa, C.A.; Kamphuis-van Ulzen, K.; Chortis, V.; Arlt, W.; Stikkelbroeck, N.; Claahsen-van der Grinten, H.L.; Hermus, A.R.M.M.

    2017-01-01

    Context: Recurrence of hypercortisolism in patients after bilateral adrenalectomy for Cushing disease is extremely rare. Patient: We present a 27-year-old man who previously underwent bilateral adrenalectomy for Cushing disease with complete clinical resolution. Cushingoid features recurred 12 years

  18. Influence of physical parameters on radiation protection and image quality in intra-oral radiology

    Science.gov (United States)

    Belinato, W.; Souza, D. N.

    2011-10-01

    In the world of diagnostic imaging, radiography is an important supplementary method for dental diagnosis. In radiology, special attention must be paid to the radiological protection of patients and health professionals, and also to image quality for correct diagnosis. In Brazil, the national rules governing the operation of medical and dental radiology were specified in 1998 by the National Sanitary Surveillance Agency, complemented in 2005 by the guide "Medical radiology: security and performance of equipment." In this study, quality control tests were performed in public clinics with dental X-ray equipment in the State of Sergipe, Brazil, with consideration of the physical parameters that influence radiological protection and also the quality of images taken in intra-oral radiography. The accuracy of the exposure time was considered acceptable for equipment with digital timers. Exposure times and focal-spot size variations can lead to increased entrance dose. Increased dose has also been associated with visual processing of radiographic film, which often requires repeating the radiographic examination.

  19. Introduction of a new removable adjustable intraoral maxillary distraction system for correction of maxillary hypoplasia.

    Science.gov (United States)

    Figueroa, Alvaro A; Polley, John W; Figueroa, Alexander L

    2009-09-01

    Distraction osteogenesis has become a treatment alternative to treat severe craniofacial skeletal dysplasias. A rigid external distraction device has been successfully used to advance the maxilla as well as the maxillary, orbital, and forehead complex (monobloc) in children as young as 2 years, adolescents, and adults. For this severe group of patients, the technique has been found to be simpler and safer than traditional surgical methods. Maxillary and midfacial advancement through distraction has been found to be extremely stable in the patients in whom the technique was used.The authors introduce an intraoral distractor for those patients requiring a moderate maxillary advancement. The advantages of the device include ease of insertion, vector adjustability, reactivation capabilities, and no need for second procedure for its removal.The above approaches have provided predictable and stable results. A detailed description of the device, necessary orthodontic and surgical procedures, case reports, and cephalometric outcomes are presented. The techniques can be applied alone or as an adjunct to traditional orthognathic and craniofacial surgical procedures.

  20. Intraoperative Hemorrhage and Postoperative Sequelae after Intraoral Vertical Ramus Osteotomy to Treat Mandibular Prognathism

    Science.gov (United States)

    Chen, Chun-Ming; Lai, Steven; Chen, Ker-Kong; Lee, Huey-Er

    2015-01-01

    Objective. To investigate the factors affecting intraoperative hemorrhage and postoperative sequelae after orthognathic surgery. Materials and Methods. Eighty patients with mandibular prognathism underwent surgical mandibular setback with intraoral vertical ramus osteotomy (IVRO). The correlation between the blood loss volume and postoperative VAS with the gender, age, and operating time was assessed using the t-test and Spearman rank correlation coefficient. The correlation between the magnitude of mandibular setback with the presence of TMJ clicking symptoms and lip sensation was also assessed. Results. The mean operating time and blood loss volume for men and women were 249.52 min and 229.39 min, and 104.03 mL and 86.12 mL, respectively. The mean VAS in men and women was 3.21 and 2.93, and 1.79 and 1.32 on the first and second postoperative days. There is no gender difference in the operating time, blood loss, VAS, TMJ symptoms, and lip numbness. The magnitude of mandibular setback was not correlated with immediate and long-term postoperative lip numbness. Conclusion. There are no gender differences in the intraoperative hemorrhage and postoperative sequelae (pain, lip numbness, and TMJ symptoms). In addition, neither symptom was significantly correlated with the amount of mandibular setback. PMID:26543855

  1. [Precision of digital impressions with TRIOS under simulated intraoral impression taking conditions].

    Science.gov (United States)

    Yang, Xin; Sun, Yi-fei; Tian, Lei; Si, Wen-jie; Feng, Hai-lan; Liu, Yi-hong

    2015-02-18

    To evaluate the precision of digital impressions taken under simulated clinical impression taking conditions with TRIOS and to compare with the precision of extraoral digitalizations. Six #14-#17 epoxy resin dentitions with extracted #16 tooth preparations embedded were made. For each artificial dentition, (1)a silicone rubber impression was taken with individual tray, poured with type IV plaster,and digitalized with 3Shape D700 model scanner for 10 times; (2) fastened to a dental simulator, 10 digital impressions for each were taken with 3Shape TRIOS intraoral scanner. To assess the precision, best-fit algorithm and 3D comparison were conducted between repeated scan models pairwise by Geomagic Qualify 12.0, exported as averaged errors (AE) and color-coded diagrams. Non-parametric analysis was performed to compare the precisions of digital impressions and model images. The color-coded diagrams were used to show the deviations distributions. The mean of AE for digital impressions was 7.058 281 μm, which was greater than that of 4.092 363 μm for the model images (Pimpressions were no more than 10 μm, which meant that the consistency between the digital impressions was good. The deviations distribution was uniform in the model images,while nonuniform in the digital impressions with greater deviations lay mainly around the shoulders and interproximal surfaces. Digital impressions with TRIOS are of good precision and up to the clinical standard. Shoulders and interproximal surfaces scanning are more difficult.

  2. Involvement of transient receptor potential vanilloid 2 in intra-oral incisional pain.

    Science.gov (United States)

    Urata, K; Shinoda, M; Ikutame, D; Iinuma, T; Iwata, K

    2018-03-05

    To examine whether transient receptor potential vanilloid 2 (TRPV2) contributes to the changes in intra-oral thermal and mechanical sensitivity following the incision of buccal mucosa. Buccal mucosal pain threshold was measured after the incision. Changes in the number of TRPV2-immunoreactive (IR) trigeminal ganglion (TG) neurons which innervate the whisker pad skin and buccal mucosa, changes in the number of isolectin B4-negative/isolectin B4-positive TRPV2-IR TG neurons which innervate the whisker pad skin and the buccal mucosa, and the effect of peripheral TRPV2 antagonism on the pain threshold of incisional whisker pad skin and buccal mucosa were examined after these injuries. Buccal mucosal pain hypersensitivities were induced on day 3 following the incision. The total number of TRPV2-IR TG neurons and the number of isolectin B4-negative TRPV2-IR TG neurons which innervate the whisker pad skin and buccal mucosa were increased. Buccal mucosal TRPV2 antagonism completely suppressed the heat and mechanical hypersensitivities, but not cold hypersensitivity. TRPV2 antagonist administration to the incisional whisker pad skin only partially suppressed pain hypersensitivities. The increased expression of TRPV2 in peptidergic TG neurons innervating the incisional buccal mucosa is predominantly involved in buccal mucosal heat hyperalgesia and mechanical allodynia following buccal mucosal incision. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.

  3. Intra-oral cone radiation therapy for selected carcinomas of the oral cavity

    International Nuclear Information System (INIS)

    Wang, C.C.; Doppke, K.P.; Biggs, P.J.

    1983-01-01

    A study of 101 patients with early carcinomas of the oral cavity, T1 and T2, treated by external cobalt 60 beam and/or intra-oral cone (IOC) radiation therapy between 1964 through 1980 was made. The two year disease-free survival rate, including surgical salvage, was 88% and the local control rate was 85%. The incidence of radiation complications, i.e., soft tissue ulceration and/or osteoradionecrosis, was 14% and varied with various tumor sites and radiation doses delivered. The present review shows that local control and radiation complications are closely related to radiation doses and varies with different tumor sites of the oral cavity. Radiation therapy dosages expressed in terms of TDF values for these lesions are herein recommended. With proper selections of lesions arising from the oral cavity, combined external beam and IOC radiation therapy has been found extremely efficacious in achieving good local tumor control and high survival rates with excellent cosmetic and functional results and minimum radiation sequalae

  4. An Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography

    Directory of Open Access Journals (Sweden)

    Hyun Jin Kim

    2016-06-01

    Full Text Available A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

  5. An intraoral miniature x-ray tube based on carbon nanotubes for dental radiography

    International Nuclear Information System (INIS)

    Kim, Hyun Jin; Kim, Hyun Nam; Raza, Hamid Saeed; Park, Han Beom; Cho, Sung Oh

    2016-01-01

    A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube

  6. An intraoral miniature x-ray tube based on carbon nanotubes for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jin; Kim, Hyun Nam; Raza, Hamid Saeed; Park, Han Beom; Cho, Sung Oh [Dept. of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2016-06-15

    A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

  7. Comparative analysis of intraoral radiographs with variation of tube angulation to detect insufficient crown margins.

    Science.gov (United States)

    Sailer, Benjamin F; Geibel, Margrit-Ann

    2013-01-01

    Variations in angulation of the x-ray tube affect the appearance of insufficient approximal crown margins on intraoral radiographs. This study examines the impact of such angular variation on the assessment of digital radiographs using three different X-ray tubes--Heliodent DS (Sirona), Gendex Expert DC (KaVo Dental) and Focus (KaVo Dental)--as well as the Gendex Visualix eHD CCD sensor (KaVo Dental). The test specimens, crowned teeth 46 from two mandibles provided by the Institute of Anatomy and Cell Biology, were examined with each tube. The results indicate great differences in the angles indicative of insufficient crown margins on X-ray images. Because of beam divergence and the crown marginal gap, the length and width of which frequently varies, it is difficult to infer any optimum angle from the data. This leads to the conclusion that at present, it is not possible to establish ideal angles for visualization of insufficient approximal crown margins.

  8. Amitriptyline and intraoral devices for migraine prevention: a randomized comparative trial

    Directory of Open Access Journals (Sweden)

    Marco A. D. Bruno

    Full Text Available ABSTRACT Objectives: Nonpharmacological treatments, such as the Nociceptive Trigeminal Inhibition Tension Suppression System (NTI-tss, are approved for migraine prophylaxis. We aimed at evaluating the effectiveness of the NTI-tss and to compare its efficacy with amitriptyline and with a sham intraoral device in the preventive treatment of migraine. Methods: Consecutive patients with migraine were randomized to receive 25 mg of amitriptyline/day (n = 34, NTI-tss (n = 33 and a non-occlusal splint (n = 30. The headache frequency was evaluated at six and 12 weeks. Results: The amitriptyline group showed, respectively, 60% and 64% reduction in attack frequency at six and 12 weeks (P = 0.000. In the NTI-tss and non-occlusal splint groups, reduction was 39% and 30%, respectively, at six weeks and 48% for both groups at 12 weeks. Conclusions: Amitriptyline proved superior to the NTI-tss and the non-occlusal splint. Despite its approval by the United States Food and Drug Administration, the NTI-tss was not superior to a sham device.

  9. Development and functional demonstration of a wireless intraoral inductive tongue computer interface for severely disabled persons.

    Science.gov (United States)

    N S Andreasen Struijk, Lotte; Lontis, Eugen R; Gaihede, Michael; Caltenco, Hector A; Lund, Morten Enemark; Schioeler, Henrik; Bentsen, Bo

    2017-08-01

    Individuals with tetraplegia depend on alternative interfaces in order to control computers and other electronic equipment. Current interfaces are often limited in the number of available control commands, and may compromise the social identity of an individual due to their undesirable appearance. The purpose of this study was to implement an alternative computer interface, which was fully embedded into the oral cavity and which provided multiple control commands. The development of a wireless, intraoral, inductive tongue computer was described. The interface encompassed a 10-key keypad area and a mouse pad area. This system was embedded wirelessly into the oral cavity of the user. The functionality of the system was demonstrated in two tetraplegic individuals and two able-bodied individuals Results: The system was invisible during use and allowed the user to type on a computer using either the keypad area or the mouse pad. The maximal typing rate was 1.8 s for repetitively typing a correct character with the keypad area and 1.4 s for repetitively typing a correct character with the mouse pad area. The results suggest that this inductive tongue computer interface provides an esthetically acceptable and functionally efficient environmental control for a severely disabled user. Implications for Rehabilitation New Design, Implementation and detection methods for intra oral assistive devices. Demonstration of wireless, powering and encapsulation techniques suitable for intra oral embedment of assistive devices. Demonstration of the functionality of a rechargeable and fully embedded intra oral tongue controlled computer input device.

  10. Intraoral Temperature Triggered Shape-Memory Effect and Sealing Capability of A Transpolyisoprene-Based Polymer

    Directory of Open Access Journals (Sweden)

    Gakuji Tsukada

    2015-11-01

    Full Text Available In dentistry, pure gutta-percha (trans-1,4-polyisoprene (TPI is widely used as a main component of root canal filling materials. TPI has an interesting shape memory formed through cross-linking, and this characteristic is expected to be very effective for development of novel dental treatments; in particular, modification of the shape recovery temperature to the intraoral temperature (37 °C will enhance the applicability of the shape-memory effect of TPI in root canal filling. In this study, trial test specimens consisting of varying proportions of TPI, cis-polyisoprene, zinc oxide, stearic acid, sulfur and dicumyl peroxide were prepared and the temperature dependence of their shape recovery, recovery stress and relaxation modulus were measured. Additionally, their sealing abilities were tested using glass tubing and a bovine incisor. As the ratio of cross-linking agent in the specimens increased, a decrease in recovery temperature and an increase in recovery stress and recovery speed were observed. In addition, the test specimen containing the highest concentration of cross-linking agent showed superior sealing ability under a thermal stimulus of 37 °C in both sealing ability tests.

  11. Influence of physical parameters on radiation protection and image quality in intra-oral radiology

    International Nuclear Information System (INIS)

    Belinato, W.; Souza, D.N.

    2011-01-01

    In the world of diagnostic imaging, radiography is an important supplementary method for dental diagnosis. In radiology, special attention must be paid to the radiological protection of patients and health professionals, and also to image quality for correct diagnosis. In Brazil, the national rules governing the operation of medical and dental radiology were specified in 1998 by the National Sanitary Surveillance Agency, complemented in 2005 by the guide 'Medical radiology: security and performance of equipment.' In this study, quality control tests were performed in public clinics with dental X-ray equipment in the State of Sergipe, Brazil, with consideration of the physical parameters that influence radiological protection and also the quality of images taken in intra-oral radiography. The accuracy of the exposure time was considered acceptable for equipment with digital timers. Exposure times and focal-spot size variations can lead to increased entrance dose. Increased dose has also been associated with visual processing of radiographic film, which often requires repeating the radiographic examination.

  12. Influence of physical parameters on radiation protection and image quality in intra-oral radiology

    Energy Technology Data Exchange (ETDEWEB)

    Belinato, W. [Instituto Federal de Ensino Basico, Tecnico e Tecnologico da Bahia, Av. Amazonas, 1350-45030-220, Zabele, Vitoria da Conquista, BA (Brazil); Departamento de Fisica, Universidade Federal de Sergipe, Av. Marechal Rondon s/n, 49100-000 Rosa Elze, Sao Cristovao, SE (Brazil); Souza, D.N., E-mail: divanizi@ufs.br [Departamento de Fisica, Universidade Federal de Sergipe, Av. Marechal Rondon s/n, 49100-000 Rosa Elze, Sao Cristovao, SE (Brazil)

    2011-10-01

    In the world of diagnostic imaging, radiography is an important supplementary method for dental diagnosis. In radiology, special attention must be paid to the radiological protection of patients and health professionals, and also to image quality for correct diagnosis. In Brazil, the national rules governing the operation of medical and dental radiology were specified in 1998 by the National Sanitary Surveillance Agency, complemented in 2005 by the guide 'Medical radiology: security and performance of equipment.' In this study, quality control tests were performed in public clinics with dental X-ray equipment in the State of Sergipe, Brazil, with consideration of the physical parameters that influence radiological protection and also the quality of images taken in intra-oral radiography. The accuracy of the exposure time was considered acceptable for equipment with digital timers. Exposure times and focal-spot size variations can lead to increased entrance dose. Increased dose has also been associated with visual processing of radiographic film, which often requires repeating the radiographic examination.

  13. Cutting and coagulation during intraoral soft tissue surgery using Er: YAG laser.

    Science.gov (United States)

    Onisor, I; Pecie, R; Chaskelis, I; Krejci, I

    2013-06-01

    To find the optimal techniques and parameters that enables Er:YAG laser to be used successfully for small intraoral soft tissue interventions, in respect to its cutting and coagulation abilities. In vitro pre-tests: 4 different Er:YAG laser units and one CO2 unit as the control were used for incision and coagulation on porcine lower jaws and optimal parameters were established for each type of intervention and each laser unit: energy, frequency, type, pulse duration and distance. 3 different types of intervention using Er:YAG units are presented: crown lengthening, gingivoplasty and maxillary labial frenectomy with parameters found in the in vitro pre-tests. The results showed a great decrease of the EMG activity of masseter and anterior temporalis muscles. Moreover, the height and width of the chewing cycles in the frontal plane increased after therapy. Er:YAG is able to provide good cutting and coagulation effects on soft tissues. Specific parameters have to be defined for each laser unit in order to obtain the desired effect. Reduced or absent water spray, defocused light beam, local anaesthesia and the most effective use of long pulses are methods to obtain optimal coagulation and bleeding control.

  14. Measurement of spectra for intra-oral X-ray beams using biological materials as attenuator

    International Nuclear Information System (INIS)

    Zenóbio, Madelon A.F.; Nogueira-Tavares, Maria S.; Zenóbio, Elton G.; Squair, Peterson Lima; Santos, Marcus A.P.; Silva, Teógenes A. da

    2011-01-01

    In diagnostic radiology, the radiation interaction probability in matter is a strong function of the X-ray energy. The knowledge of the X-ray energy spectral distribution allows optimizing the radiographic imaging system in order to obtain high quality images with as low as reasonably achievable patient doses. In this study, transmitted X-ray spectra through dentin and enamel that are existing materials in intra-oral radiology were experimentally determined in an X-ray equipment with 40–70 kV variable range. Dentin and enamel samples with 0.4–3.8 and 0.6–2.6 mm thick were used as attenuators. X-ray transmitted spectra were measured with XR-100T model CdTe detector and half-value layers (HVL) were determined. Characteristics of both dentin and enamel transmitted spectra showed that they have differences in the penetration power in matter and in the spectrum distribution. The results will be useful for phantom developments based on dentin and enamel for image quality control in dental radiology. - Highlights: ► The X-ray energy spectral distribution, optimize the radiographic imaging system. Transmitted X-ray spectra through dentin and enamel were experimentally determined. X-ray transmitted spectra were measured (XR-100T model CdTe detector). The transmitted spectra showed differences in the penetration power and spectrum distribution. Dentin and enamel transmitted spectra will be useful for phantom developments.

  15. Evaluation of X-Ray Protective Measurements in Intraoral Radiography Equipped Centers in Yazd

    Directory of Open Access Journals (Sweden)

    D.Goodarzi Pour

    2005-02-01

    Full Text Available Statement of Problem: A few decades have past from using radiographic technology as an accurate paraclinical method and always protective measurements is applicated against ionizing radiation. As dentalradiography is a routine procedure in dentistry the importance of protective strategies is clear.Propose: The aim of this descriptive study is to evaluate the protection principles in centers which haveintraoral radiographic devices in Yazd.Material and Methods: We have considered all three aspects of practitioner, environment and patientprotection using questionnaire and visiting those centers.Results: 33/7% of dental offices ,10 clinics ,3 institution and faculty of dentistry had intraoral radiographicequipments. Stablishment of protection principles for radiographer was favorable. 7.7% of centers had x-ray room with leaded walls, 23.1% had curtain , in 69/2% of centers radiographers stood in correct position anddistance while taking radiograph. Regarding to protection of environment, beams leakage control in 23.1% dental offices, 70% of clinics, all institution and faculty of dentistry have done.Conclusion: Non of the centers used rectangular localizator, thyroid shield, film holder and just some centers used leaded apron in specific circumstances. We have concluded that patient protection constitute less consideration. Generally lack of protective consideration is related to deficient knowledge of operators. Lackof information about protection equipments causes decrease of demanding of these tools and ultimately lack of these equipments in the market.

  16. Effects of intraoral aging on surface properties of coated nickel-titanium archwires.

    Science.gov (United States)

    Rongo, Roberto; Ametrano, Gianluca; Gloria, Antonio; Spagnuolo, Gianrico; Galeotti, Angela; Paduano, Sergio; Valletta, Rosa; D'Antò, Vincenzo

    2014-07-01

    To evaluate the effects of intraoral aging on surface properties of esthetic and conventional nickel-titanium (NiTi) archwires. Five NiTi wires were considered for this study (Sentalloy, Sentalloy High Aesthetic, Superelastic Titanium Memory Wire, Esthetic Superelastic Titanium Memory Wire, and EverWhite). For each type of wire, four samples were analyzed as received and after 1 month of clinical use by an atomic force microscope (AFM) and a scanning electronic microscope (SEM). To evaluate sliding resistance, two stainless steel plates with three metallic or three monocrystalline brackets, bonded in passive configuration, were manufactured; four as-received and retrieved samples for every wire were pulled five times at 5 mm/min for 1 minute by means of an Instron 5566, recording the greatest friction value (N). Data were analyzed by one-way analysis of variance and by Student's t-test. After clinical use, surface roughness increased considerably. The SEM images showed homogeneity for the as-received control wires; however, after clinical use esthetic wires exhibited a heterogeneous surface with craters and bumps. The lowest levels of friction were observed with the as-received Superelastic Titanium Memory Wire on metallic brackets. When tested on ceramic brackets, all the wires exhibited an increase in friction (t-test; P Sentalloy, showed a statistically significant increase in friction between the as-received and retrieved groups (t-test; P < .05). Clinical use of the orthodontic wires increases their surface roughness and the level of friction.

  17. Dental and skeletal changes after intraoral molar distalization with sectional jig assembly.

    Science.gov (United States)

    Gulati, S; Kharbanda, O P; Parkash, H

    1998-09-01

    The present study was conducted on 10 subjects to evaluate dental and skeletal changes after intraoral molar distalization. The maxillary molars were distalized with a sectional jig assembly. Sentalloy open coil springs were used to exert 150 gm of force for a period of 12 weeks. A modified Nance appliance was the main source of anchorage. The pre- and postdistalization records included dental study casts, clinical photographs, and cephalograms. A total of 665 readings recorded from lateral cephalograms and dental casts were subjected to statistical analysis. The mean distal movement of the first molar was 2.78 mm, which was highly significant (o < 0.001). It moved distally at the rate of 0.86 mm/month. There was clinically some distal tipping (3.50 degrees) and distopalatal rotation (2.40 degrees). These changes were statistically significant (p < 0.001). The second molars accompanied the first molars and moved distally by nearly the same amount. There was 1.00 mm increase in the overjet and 2.60 degrees mesial tip of second premolar. The changes in the facial skeleton and dentition bases were minimal and statistically not significant. However, there was clockwise rotation of the mandible of 1.30 degrees that was statistically significant. This was the result of molar extrusion (1.60 mm).

  18. Intraoperative Hemorrhage and Postoperative Sequelae after Intraoral Vertical Ramus Osteotomy to Treat Mandibular Prognathism

    Directory of Open Access Journals (Sweden)

    Chun-Ming Chen

    2015-01-01

    Full Text Available Objective. To investigate the factors affecting intraoperative hemorrhage and postoperative sequelae after orthognathic surgery. Materials and Methods. Eighty patients with mandibular prognathism underwent surgical mandibular setback with intraoral vertical ramus osteotomy (IVRO. The correlation between the blood loss volume and postoperative VAS with the gender, age, and operating time was assessed using the t-test and Spearman rank correlation coefficient. The correlation between the magnitude of mandibular setback with the presence of TMJ clicking symptoms and lip sensation was also assessed. Results. The mean operating time and blood loss volume for men and women were 249.52 min and 229.39 min, and 104.03 mL and 86.12 mL, respectively. The mean VAS in men and women was 3.21 and 2.93, and 1.79 and 1.32 on the first and second postoperative days. There is no gender difference in the operating time, blood loss, VAS, TMJ symptoms, and lip numbness. The magnitude of mandibular setback was not correlated with immediate and long-term postoperative lip numbness. Conclusion. There are no gender differences in the intraoperative hemorrhage and postoperative sequelae (pain, lip numbness, and TMJ symptoms. In addition, neither symptom was significantly correlated with the amount of mandibular setback.

  19. Case Series of an Intraoral Balancing Appliance Therapy on Subjective Symptom Severity and Cervical Spine Alignment

    Directory of Open Access Journals (Sweden)

    Young Jun Lee

    2013-01-01

    Full Text Available Objective. The objective of this study was to investigate the effect of a holistic intraoral appliance (OA on cervical spine alignment and subjective symptom severity. Design. An observational study on case series with holistic OA therapy. Setting. An outpatient clinic for holistic temporomandibular joint (TMJ therapy under the supervision of the Pain Center, CHA Biomedical center, CHA University. Subjects. Ambulatory patients presenting with diverse chief complaints in the holistic TMJ clinic. Main Measures. Any immediate change in the curvature of cervical spine and the degree of atlantoaxial rotation was investigated in the images of simple X-ray and computed tomography of cervical spine with or without OA. Changes of subjective symptom severity were also analyzed for the holistic OA therapy cases. Results. A total of 59 cases were reviewed. Alignment of upper cervical spine rotation showed an immediate improvement (. Changes of subjective symptom severity also showed significant improvement (. Conclusion. These cases revealed rudimentary clinical evidence that holistic OA therapy may be related to an alleviated symptom severity and an improved cervical spinal alignment. These results show that further researches may warrant for the holistic TMJ therapy.

  20. Danish Exports and Danish Bilateral Aid

    DEFF Research Database (Denmark)

    Hansen, Henrik; Rand, John

    higher in the 1980s compared to in particular the most recent decade. This may be related to factors such as untying of aid in the same period. The econometric analysis has two important limitations. First of all, the model can only give information about marginal changes in aid. As a decision to give...... and trade policies. The main result of the study is that Danish bilateral aid has a positive and statistically significant impact on Danish exports to the recipient countries. Bilateral development assistance may affect exports through several channels. Three of the main channels are direct aid tying......; increasing recipient income where higher income leads to higher imports, and decreased trade costs, say due to improved information about cultural and administrative customs and practices. Thus, as for preferential trade arrangements, bilateral aid has two potential economic effects; trade creation working...

  1. Noise reduction with complex bilateral filter.

    Science.gov (United States)

    Matsumoto, Mitsuharu

    2017-12-01

    This study introduces a noise reduction technique that uses a complex bilateral filter. A bilateral filter is a nonlinear filter originally developed for images that can reduce noise while preserving edge information. It is an attractive filter and has been used in many applications in image processing. When it is applied to an acoustical signal, small-amplitude noise is reduced while the speech signal is preserved. However, a bilateral filter cannot handle noise with relatively large amplitudes owing to its innate characteristics. In this study, the noisy signal is transformed into the time-frequency domain and the filter is improved to handle complex spectra. The high-amplitude noise is reduced in the time-frequency domain via the proposed filter. The features and the potential of the proposed filter are also confirmed through experiments.

  2. Fibrovascular tissue in bilateral juxtafoveal telangiectasis.

    Science.gov (United States)

    Park, D; Schatz, H; McDonald, H R; Johnson, R N

    1996-09-01

    To study the natural history and retinal findings associated with the intraretinal and subretinal fibrovascular tissues that develop in the late phases of bilateral juxtafoveal telangiectasis. The records of 10 patients (11 eyes) with bilateral juxtafoveal telangiectasis who developed these fibrovascular tissues were examined. Throughout the follow-up period (average 44 months), only 2 eyes (18%) lost 2 or more lines of vision; the final visual acuities were similar for the eyes both with and without fibrovascular tissues. Sixty-four percent of fibrovascular tissues showed little to no growth. Eyes with fibrovascular tissue commonly had retinal pigment epithelial hyperplasia (72%), draining retinal venules (82%), and retinal vascular distortion (64%). Fibrovascular tissues of bilateral juxtafoveal telangiectasis have little proliferative potential and minimal effects on visual acuity. Nevertheless, these fibrovascular tissues do remodel over time, leading to retinal vascular distortion. Given these benign findings, the role of laser photocoagulation treatment of these tissues is questionable.

  3. Bilateral Giant Retinal Tear and Sequential Vitrectomy.

    Science.gov (United States)

    Mustapha, Mushawiahti; Roufail Franzco, Edward

    2017-01-01

    To describe the excellent outcome of surgery for bilateral giant retinal tears (GRTs) with better options of endotamponade. This is a case report of a 62-year-old man who presented with bilateral GRTs and associated retinal detachment. The tear in the right eye was supero-temporal and silicone oil was used as an endotamponade. The tear in the left eye was infero-temporal and perfluorocarbon liquid was used as an endotamponade. The outcome at 6 months after surgery was excellent with visual acuities of 6/6 in both eyes. Improved availability of endotamponade agents allows repair of bilateral GRTs to be done at the same time, with good surgical outcomes.

  4. Bilateral Supernumerary Kidney: A Very Rare Presentation

    International Nuclear Information System (INIS)

    Keskin, Suat; Batur, Abdussamet; Keskin, Zeynep; Koc, Abdulkadir; Firat Ozcan, Irfan

    2014-01-01

    To our knowledge, bilateral supernumerary kidney is a very rare renal abnormality and there are five cases presented in the literature. It is difficult to diagnose supernumerary kidney and clinicians have not detected most cases preoperatively. Laboratory and imaging studies were acquired and carefully examined. The normal laboratory tests were found. Emergency ultrasonography was performed and they revealed no signs of parenchymal abnormality in both kidneys. Serial imaging study including enhanced computed tomography (CT) was performed. An imaging study identified bilateral supernumerary kidney with expanded collecting systems. On each side, significant rotation anomaly was found. In addition, there were two different renal arteries originating from the aorta. This report presents radiological determinations of supernumerary kidney bilaterally in a young man. We think that CT commonly appears to be enough for the diagnosis of supernumerary kidneys

  5. Bilateral Supernumerary Kidney: A Very Rare Presentation

    Science.gov (United States)

    Keskin, Suat; Batur, Abdussamet; Keskin, Zeynep; Koc, Abdulkadir; Firat Ozcan, Irfan

    2014-01-01

    To our knowledge, bilateral supernumerary kidney is a very rare renal abnormality and there are five cases presented in the literature. It is difficult to diagnose supernumerary kidney and clinicians have not detected most cases preoperatively. Laboratory and imaging studies were acquired and carefully examined. The normal laboratory tests were found. Emergency ultrasonography was performed and they revealed no signs of parenchymal abnormality in both kidneys. Serial imaging study including enhanced computed tomography (CT) was performed. An imaging study identified bilateral supernumerary kidney with expanded collecting systems. On each side, significant rotation anomaly was found. In addition, there were two different renal arteries originating from the aorta. This report presents radiological determinations of supernumerary kidney bilaterally in a young man. We think that CT commonly appears to be enough for the diagnosis of supernumerary kidneys. PMID:25780543

  6. Bilateral acute iris transillumination: Case report

    Directory of Open Access Journals (Sweden)

    Cumali Degirmenci

    2016-04-01

    Full Text Available Bilateral acute iris transillumination (BAIT is a recently defined disease characterized with bilateral acute, severe pigment dispersion of iris and pupil sphincter paralysis. The etiopathogenesis of the disease is unknown, but antibiotics such as moxifloxacin, clarithromycin, viral infections, and fumigation therapies were considered as probable etiologic factors. A 33-year-old female was referred to our clinic for acute iridocyclitis refractory to azathioprine, colchicum and corticosteroid treatments. Ophthalmic examination revealed bilateral pigment dispersion, significant iris transillumination, heavy pigment deposition in iridocorneal angle, and elevated intraocular pressure. Upon systemic evaluation she was found to have bacterial urinary tract infection. BAIT is an important cause of pigment dispersion and clinicians must be vigilant for this condition to avoid unnecessary diagnostic tests and treatment.

  7. Bilateral clear cell sarcoma of the kidney

    International Nuclear Information System (INIS)

    Zekri, W.; Yehia, D.; Alfaar, A.S.; Elshafie, M.M.; Younes, A.A.; Zaghloul, M.S.; El-Kinaai, N.; Taha, H.; Refaat, A.; Zekri, W.; Elshafie, M.M.; Zaghloul, M.S.; Taha, H.; Refaat, A.; Younes, A.A.; Alfaar, A.S.; Yehia, D.

    2015-01-01

    Clear cell sarcoma of the kidney (CCSK) accounts for 2-5% of all pediatric renal malignancies, and is known for its propensity to metastasize to bone and other sites. We are reporting two cases with bilateral CCSK that were diagnosed at our institution. One patient initially presented with bilateral renal masses, as well as pulmonary, hepatic and bone metastasis; while other present only with bilateral masses with no evident distant metastasis. Both patients received aggressive neo-adjuvant chemotherapy to decrease tumor size. One patient completed his designated treatment and initially showed complete remission (CR); eventually suffering from relapse. The other patient’s tumor progressed during the course of chemotherapy. Both cases manifested brain dissemination at the time of relapse or progression. This emphasizes the importance of staging stratification in CCSK. This also illustrates CCSK’s ability to metastasize to bone and other sites including the brain (a primary relapse site in our cases)

  8. Prognosis of synchronous bilateral breast cancer

    DEFF Research Database (Denmark)

    Holm, Marianne; Tjønneland, Anne; Balslev, Eva

    2014-01-01

    Currently, no consistent evidence-based guidelines for the management of synchronous bilateral breast cancer (SBBC) exist and it is uncertain how presenting with SBBC affects patients' prognosis. We conducted a review of studies analyzing the association between SBBC and prognosis. The studies...... that reported adjusted effect measures were included in meta-analyses of effect of bilaterality on breast cancer mortality. From 57 initially identified records 17 studies from 11 different countries including 8,050 SBBC patients were included. The quality of the studies varied but was generally low with small...... sample sizes, and lack of consistent, detailed histo-pathological information. When doing meta-analysis on the subgroup of studies that provided adjusted effect estimates on breast cancer mortality (nine studies including 3,631 SBBC cases), we found that bilaterality in itself had a negative impact...

  9. Sarcoidosis Presenting as Bilateral Vocal Fold Immobility.

    Science.gov (United States)

    Hintze, Justin M; Gnagi, Sharon H; Lott, David G

    2018-05-01

    Bilateral true vocal fold paralysis is rarely attributable to inflammatory diseases. Sarcoidosis is a rare but important etiology of bilateral true vocal fold paralysis by compressive lymphadenopathy, granulomatous infiltration, and neural involvement. We describe the first reported case of sarcoidosis presenting as bilateral vocal fold immobility caused by direct fixation by granulomatous infiltration severe enough to necessitate tracheostomy insertion. In addition, we discuss the presentation, the pathophysiology, and the treatment of this disease with a review of the literature of previously reported cases of sarcoidosis-related vocal fold immobility. Sarcoidosis should therefore be an important consideration for the otolaryngologist's differential diagnosis of true vocal fold immobility. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  10. Similarity in Bilateral Isolated Internal Orbital Fractures.

    Science.gov (United States)

    Chen, Hung-Chang; Cox, Jacob T; Sanyal, Abanti; Mahoney, Nicholas R

    2018-04-13

    In evaluating patients sustaining bilateral isolated internal orbital fractures, the authors have observed both similar fracture locations and also similar expansion of orbital volumes. In this study, we aim to investigate if there is a propensity for the 2 orbits to fracture in symmetrically similar patterns when sustaining similar trauma. A retrospective chart review was performed studying all cases at our institution of bilateral isolated internal orbital fractures involving the medial wall and/or the floor at the time of presentation. The similarity of the bilateral fracture locations was evaluated using the Fisher's exact test. The bilateral expanded orbital volumes were analyzed using the Wilcoxon signed-rank test to assess for orbital volume similarity. Twenty-four patients with bilateral internal orbital fractures were analyzed for fracture location similarity. Seventeen patients (70.8%) had 100% concordance in the orbital subregion fractured, and the association between the right and the left orbital fracture subregion locations was statistically significant (P < 0.0001). Fifteen patients were analyzed for orbital volume similarity. The average orbital cavity volume was 31.2 ± 3.8 cm on the right and 32.0 ± 3.7 cm on the left. There was a statistically significant difference between right and left orbital cavity volumes (P = 0.0026). The data from this study suggest that an individual who suffers isolated bilateral internal orbital fractures has a statistically significant similarity in the location of their orbital fractures. However, there does not appear to be statistically significant similarity in the expansion of the orbital volumes in these patients.

  11. Infliximab en pacientes con enfermedad ocular inflamatoria, refractarios a DARMES

    Directory of Open Access Journals (Sweden)

    Elmer R. García-Salazar

    2013-07-01

    Full Text Available Se describe la experiencia con infliximab (anticuerpo monoclonal con una potente acción antiinflamatoria en el tratamiento de enfermedades oculares inflamatorias secundarias a patologías reumáticas y refractarias a drogas antirreumáticas modificadoras de la enfermedad (DARMES. Se evaluó el caso de una paciente de 50 años con artritis reumatoide (AR de fondo activo y una paciente de 37 años con vasculitis anticuerpos anticitoplasma de neutrófilos especifico para mieloperoxidasa (ANCA MPO sin compromiso de órgano noble, ambas con escleritis bilateral y perforación con prolapso de iris del ojo izquierdo. Ellas recibieron infliximab EV en dosis de 3 a 5 mg/kg/dosis, según el esquema, a las 0, 2, 6 y 8 semanas. Infliximab resultó eficaz y seguro para el tratamiento de escleritis asociada a AR y vasculitis ANCA MPO positivo, refractaria a tratamiento con DARMES y corticoides en dosis altas. Los injertos de tejido esclerocorneal evolucionaron favorablemente con infliximab.

  12. Bilateral double level tibial lengthening in dwarfism.

    Science.gov (United States)

    Burghardt, Rolf D; Yoshino, Koichi; Kashiwagi, Naoya; Yoshino, Shigeo; Bhave, Anil; Paley, Dror; Herzenberg, John E

    2015-12-01

    Outcome assessment after double level tibial lengthening in patients with dwarfism. Fourteen patients with dwarfism were analyzed after bilateral simultaneous double level tibial lengthening. Average age was 15.1 years. Average lengthening was 13.5 cm. The two levels were lengthened by an average of 7.5 cm proximally and 6.0 cm distally. Concomitant deformities were also addressed during lengthening. External fixation treatment time averaged 8.8 months. Healing index averaged 0.7 months/cm. Bilateral tibial lengthening for dwarfism is difficult, but the results are usually quite gratifying.

  13. Spontaneous Bilateral Meningoencephalocoeles of the Temporal Bones

    Directory of Open Access Journals (Sweden)

    Oliver Rose

    2013-01-01

    Full Text Available Spontaneous tegmen tympani defects are rare with even rarer bilateral cases. The symptoms are nonspecific; hence, a high index of suspicion is required to prevent serious intracranial complications. We present a case of spontaneous bilateral tegmen tympani defects with associated meningoencephalocoeles in a 54-year-old male who presented with the signs and symptoms of severe meningitis. After careful workup which included a lumbar puncture, CT and MRI scans, both defects were repaired using a middle fossa approach. The patient made an uneventful recovery with complete cessation of otorrhoea and improvement in his hearing.

  14. Accuracy of full-arch scans using intraoral and extraoral scanners: an in vitro study using a new method of evaluation.

    Science.gov (United States)

    Muallah, Jonas; Wesemann, Christian; Nowak, Roxana; Robben, Jan; Mah, James; Pospiech, Peter; Bumann, Axel

    The aim of this study was to compare the accuracy of six intraoral scanners as regards clinically relevant distances using a new method of evaluation. An additional objective was to compare intraoral scanners with the indirect digitization of model scanners. A resin master model was created by 3D printing and drilled in five places to reflect the following distances: intermolar width (IMW), intercanine width (ICW), and arch length (AL). To determine a gold standard, the distances were measured with a coordinate measuring instrument (Zeiss O-Inspect 422). The master model was scanned 37 times with the following intraoral scanners: Apollo DI (Sirona), CS 3500 (Carestream Dental), iTero (Cadent), PlanScan (Planmeca), Trios (3Shape), and True Definition (3M Espe), and indirectly digitized with the OrthoX Scan (Dentaurum). The digital models were then measured, and deviations from the gold standard calculated. Significant differences were found between the devices. Among the intraoral scanners, Trios and iTero showed the most accurate results, although CS 3500, True Definition, and Apollo DI achieved comparable results. PlanScan demonstrated the highest deviations from the gold standard, and presented a high standard deviation (SD). Direct digitization revealed comparable (and, in fact, slightly higher) accuracy than indirect digitization. Both indirect digitization and most of the intraoral scanners were therefore demonstrated to be suitable for use in the orthodontic office, with the exception of PlanScan, which did not meet the demands of individual orthodontic treatment.

  15. Bilateral empyema thoracis treated simultaneously with video ...

    African Journals Online (AJOL)

    Keywords: bilateral empyema, children, pneumonia, simultaneous ... Department of Pediatric Surgery, J.J. Hospital and Grant Medical College, ... occurrence of an acute inflammatory reaction. ... specific organism has been associated with the patients of ... 8 Santos Jw. Community-acquired staphylococcal pneumonia.

  16. Bilateral gluteal abscesses and myofibrosis complicating ...

    African Journals Online (AJOL)

    BACKGROUND: There is paucity of reports on the musculoskeletal complications of pentazocine abuse in Nigeria.The aim was to report a case of bilateral gluteal abscesses and myofibrosis as a consequence of parenteral pentazocine abuse. CASE SUMMARY: We report a case of a 39 year old housewife who presented ...

  17. Bilateral Odontogenic Keratocyst of the Mandible

    OpenAIRE

    Ram, Hari; Mohammad, Shadab; Husain, Nuzhat; Gupta, Shalini; Kumar, Ajay

    2011-01-01

    Odontogenic keratocyst (OKC) is a cyst of dental origin with an aggressive clinical behavior, having high recurrence rate. Multiple cysts are associated with bifid-rib basal cell nevus syndrome (Gorlin syndrome). We present a case of bilateral odontogenic keratocyst in a cleft lip patient.

  18. Bilateral Facial Nerve Palsy: A Diagnostic Dilemma

    Directory of Open Access Journals (Sweden)

    Sohil Pothiawala

    2012-01-01

    Conclusion. We reinforce the importance of considering the range of differential diagnosis in all cases presenting with bilateral FNP. These patients warrant admission and prompt laboratory and radiological investigation for evaluation of the underlying cause and specific further management as relevant.

  19. De Bilateral Security Agreement voor Afghanistan

    NARCIS (Netherlands)

    Voetelink, J.

    2013-01-01

    Wanneer de VS en de NAVO na 2014 de stationering van troepen in Afghanistan willen voortzetten, zullen zij hiervoor nieuwe internationale overeenkomsten moeten sluiten. De onderhandelingen tussen Afghanistan en de VS zijn het afgelopen jaar gestart en moeten leiden tot de Bilateral Security

  20. Bilateral breast cancer : mammographic and clinical findings

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Oh, Ki Keun; Jun, Hwang Yoon; Lee, Byung Chan; Lee, Kyong Sik; Lee, Yong Hee

    1997-01-01

    To evaluate the mammographic and clinical features of bilateral breast cancer. We retrospectively reviewed clinical records(n=23) and mammograms (n=15) of 23 patients with bilateral breast cancer. Patients' age, location of the tumor and pathologic staging were determined from clinical records. Mammographic features were classified as spiculated mass, nonspiculated mass, mass with microcalcification, microcalcification only, asymmetric density, and normal. Of the 23 cases of bilateral breast cancer, 8(34.8%) were synchronous and 15(65.2%) were metachronous. Age at diagnosis of cancer in the first breast was between 27 and 59(mean 43) years ; there was no statistically significant difference in mean age between patients with synchronous and metachronous cancer. The mean interval between the diagnosis of each lesion of the metachronous pairs was 9.1 years. In 11 of 23 cases(48%), tumors were locaated in the same quadrant, and in the other 12 cases(52%), they were in different quadrant. At mammography, five of 15 metachronous cancers(33%) were similar in appearance and 10 pairs(67%) were different. In 4 of 23 cases(17%), cancer in the first breast was at stage 0 and stage 1, and in 13 of 23(57%), cancer in the second breast was at this same stage. In bilateral breast cancer, the two breasts frequently show different mammographic features. Cancer of the second breast was at an early stage; this suggest that regular examination and mammography are important and can allow early detection of contralateral breast cancer

  1. Amnesia due to bilateral hippocampal glioblastoma

    International Nuclear Information System (INIS)

    Shimauchi, M.; Wakisaka, S.; Kinoshita, K.

    1989-01-01

    The authors report a unique case of glioblastoma which caused permanent amnesia. Magnetic resonance imaging showed the lesion to be limited to the hippocampal formation bilaterally. Although glioblastoma extends frequently into fiber pathways and expands into the opposite cerebral hemisphere, making a 'butterfly' lesion, it is unusual for it to invade the limbic system selectively to this extent. (orig.)

  2. Pott's Spine with Bilateral Psoas Abscesses

    OpenAIRE

    Masavkar, Sanjeevani; Shanbag, Preeti; Inamdar, Prithi

    2012-01-01

    A high degree of suspicion and appropriate imaging studies are required for the early diagnosis of Pott's spine. We describe a 4-year-old boy with Pott's disease of the lumbar spine with bilateral psoas abscesses. The child responded to conservative treatment with antituberculous treatment and ultrasonographically guided percutaneous drainage of the abscesses.

  3. Bilateral duplication of the internal auditory canal

    International Nuclear Information System (INIS)

    Weon, Young Cheol; Kim, Jae Hyoung; Choi, Sung Kyu; Koo, Ja-Won

    2007-01-01

    Duplication of the internal auditory canal is an extremely rare temporal bone anomaly that is believed to result from aplasia or hypoplasia of the vestibulocochlear nerve. We report bilateral duplication of the internal auditory canal in a 28-month-old boy with developmental delay and sensorineural hearing loss. (orig.)

  4. Cochlear implantation in a bilateral Mondini dysplasia.

    Science.gov (United States)

    Turrini, M; Orzan, E; Gabana, M; Genovese, E; Arslan, E; Fisch, U

    1997-01-01

    We report the speech perception progress and programming procedures of a case of congenital profound deafness and bilateral Mondini dysplasia implanted with a Nucleus 20 + 2 cochlear implant at the age of six. Unclear relations between electrodes array and cochlear partition made implant programming difficult and non-standard procedures were set. Cochlear implantation may give excellent rehabilitative results also in cochleae with malformation.

  5. Bilateral cheiloschisis in bovine - A case report

    Directory of Open Access Journals (Sweden)

    Saulo Andrade Caldas

    2014-01-01

    Full Text Available ABSTRACT. Caldas S.A., Nogueira V.A., Lima A.E.S., Aragão A.P., d’Avila M.S., Santos A.M., Miranda I.C., Costa S.Z.R. & Peixoto T.C. [Bilateral cheiloschisis in bovine - A case report.] Queilosquise bilateral em bovino - Relato de caso. Revista Brasileira de Medicina Veterinária, 36(1:55-59, 2014. Departamento de Medicina e Cirurgia Veterinária, Instituto de Veterinária, Universidade Federal Rural do Rio de Janeiro, BR 465 Km 7, Seropédica RJ 23890-000, Brasil. E-mail: saulocaldas@hotmail.com A case of bilateral queilosquise in a cattle two years old was reported. Clinically, there was cachexia, difficulty in grasping food and water intake. The clinical examination revealed that the nasal orifices were discontinuous with the upper lip, which allowed communication between the nostrils and mouth in its rostral portion, crowding of incisors (tweezers, as well as exposure of medium and the 2nd corner and of the tongue. In this case, the bilateral queilosquise was the result of flaws in fusion of the maxillary process and the medial nasal process and its surroundings, probably due to mineral deficiencies of pregnant cow. This pathogenesis was suggested by excluding other possible causes, the knowledge of the existence of mineral deficiencies in the region where the event occurred and bad nutritional status of pregnant female.

  6. Simultaneous bilateral contracture of the infraspinatus muscle.

    Science.gov (United States)

    Franch, J; Bertran, J; Remolins, G; Fontecha, P; Díaz-Bertrana, M C; Durall, I

    2009-01-01

    A case of bilateral fibrotic contracture of the infraspinatus muscles in a five-year-old Belgian Shepherd dog is described. The dog was presented with progressive forelimb lameness with postural and gait abnormalities three months after an episode of overexertion. When walking, the lower part of both forelimbs swung in a lateral arc causing a circumduction movement and in the standing position, the dog showed elbow adduction with external rotation of the distal part of both front limbs. Orthopaedic examination revealed bilateral atrophy of both infraspinatus and supraspinatus muscles and restriction in the range of motion of both shoulders, especially when attempting abduction and flexion. No specific findings were observed in the shoulder or elbow radiographs but hyperechogenic areas were evident in the ultrasonographic examination of both infraspinatus muscles. A diagnosis of fibrotic contracture of both infraspinatus muscles was established and bilateral tenectomy of the insertion tendons of the infraspinatus muscles was performed. Complete recovery of the animal was achieved after the surgery, which was confirmed in a long-term follow-up (10 months). In conclusion, physical examination and ultrasonography allowed a proper diagnosis of the condition, and tenectomy of the infraspinatus muscles resulted in a complete recovery of the patient even with bilateral involvement.

  7. Bilateral synchronous rupture of the quadriceps tendon.

    LENUS (Irish Health Repository)

    Ellanti, P

    2012-09-01

    Bilateral simultaneous rupture of the quadriceps tendon is a rare entity. They are often associated with degenerative changes of the tendons and predisposing conditions such as diabetes or excessive steroid use. They most commonly tend to occur in patients of 40 years of age or older.

  8. MODEL OF TEACHING PROFESSION SPECIFIC BILATERAL TRANSLATION

    Directory of Open Access Journals (Sweden)

    Yana Fabrychna

    2017-03-01

    Full Text Available The article deals with the author’s interpretation of the process of teaching profession specific bilateral translation to student teacher of English in the Master’s program. The goal of the model of teaching profession specific bilateral translation development is to determine the logical sequence of educational activities of the teacher as the organizer of the educational process and students as its members. English and Ukrainian texts on methods of foreign languages and cultures teaching are defined as the object of study. Learning activities aimed at the development of student teachers of English profession specific competence in bilateral translation and Translation Proficiency Language Portfolio for Student Teachers of English are suggested as teaching tools. The realization of the model of teaching profession specific bilateral translation to student teachers of English in the Master’s program is suggested within the module topics of the academic discipline «Practice of English as the first foreign language»: Globalization; Localization; Education; Work; The role of new communication technologies in personal and professional development. We believe that the amount of time needed for efficient functioning of the model is 48 academic hours, which was determined by calculating the total number of academic hours allotted for the academic discipline «Practice of English as the first foreign language» in Ukrainian universities. Peculiarities of the model realization as well as learning goals and content of class activities and home self-study work of students are outlined.

  9. Port-contact systems in bilateral telemanipulation

    NARCIS (Netherlands)

    Secchi, C; Stramigioli, Stefano; Fantuzzi, C.

    2007-01-01

    In this paper we develop one of the first control applications of the recently proposed port-contact framework. We show how it is possible to model and control a bilateral telemanipulation system using port-contact systems and we develop a port-contact impedance controller that allows to impose a

  10. Bilateral eyelid edema : Cutis laxa or blepharochalasis?

    NARCIS (Netherlands)

    Braakenburg, A; Nicolai, JPA

    A 59-year-old woman with massive bilateral edema of the upper and lower eyelids is presented. The edema occurred suddenly and without provocation. No cause could be identified despite a multitude of examinations. Initially the patient was diagnosed as having blepharochalasis, but later skin biopsy

  11. Ankylosing Spondylitis Associated With Bilateral TMJ Ankylosis

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ju Seop; Koh, Kwang Joon [Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Chonbuk National University, Iksan (Korea, Republic of)

    2000-09-15

    A 31-year-old male with severe limitation of mouth opening was referred to our department of Chonbuk National University Hospital. The physical status of the patient was hyposthenic. Extraoral examination showed no condylar movement of the both temporomandibular joints, no pain, no faical swelling or paresthesia. Intraoral examination showed several cervical caries on the upper anterior teeth, and gingival swelling on the whole dentition. Transcranial view showed no condylar movement, and narrowing of joint spaces. Chest P-A view showed straightening of thoracic, lumbar spine, and squaring of vertebrae of the same spines. Conventional lateral radiograph of cervical spine showed calcification of the intervertebral ligament. Computed tomograph showed extensive bone formation between temporal bone and the both condylar heads. Labortory findings showed positive reaction on HLA-B27 histocompatibility antigen and increased level of IgA, IgG, ESR. Based on the clinical, radiographic, and the labortary findings, final diagnosis was made as bony ankylosis of the both temporomandibular joints secondary to ankylosing spondylitis.

  12. Bilateral breast carcinoma: results with breast conservation therapy and a comparison with bilateral mastectomy

    International Nuclear Information System (INIS)

    Kim, David H.; Haffty, Bruce G.

    1996-01-01

    Purpose: To assess outcome of patients with bilateral breast carcinoma treated with bilateral breast conserving surgery with radiation therapy (CS+RT) and to compare their outcome to (1) patients with unilateral disease treated with CS+RT and (2) patients of comparable stage treated with bilateral mastectomy. Methods and Materials: The charts of all patients with the diagnosis of breast cancer treated with CS+RT at our facilities prior to 1993 were reviewed to identify patients with bilateral disease. A total of 50 patients identified as having bilateral breast cancer conservatively treated(BCT) served as the index population. Out of the 50 patients, 23 presented with synchronous bilateral breast cancer and 27 presented with metachronous bilateral breast cancer. A group of 984 patients with unilateral breast cancer (UCT) treated with CS+RT during the same time interval served as the first control group. A second control group was comprised of 42 patients with early stage bilateral breast cancer presenting during the same time interval treated with bilateral mastectomy (BMAST). Patients who had locally advanced disease in either breast or those patients treated exclusively for lobular carcinoma in situ in either breast were excluded from the analysis. Of the 42 BMAST patients, 33 presented with synchronous disease and nine presented with metachronous disease. Local-regional relapse rates were calculated from the date of treatment of each breast. Overall survival and distant relapse rates were calculated from the date of treatment of the second breast cancer diagnosed. Survival curves were calculated via the life table method and statistical comparisons between curves were performed using the log rank statistic. Chi square analysis was used to detect differences between categorical variables. Results: As of December 1995, the median follow-up of the bilateral conservatively treated patient population was 9.4 years. No statistically significant differences were noted

  13. A novel technique for reference point generation to aid in intraoral scan alignment.

    Science.gov (United States)

    Renne, Walter G; Evans, Zachary P; Mennito, Anthony; Ludlow, Mark

    2017-11-12

    When using a completely digital workflow on larger prosthetic cases it is often difficult to communicate to the laboratory or chairside Computer Aided Design and Computer Aided Manufacturing system the provisional prosthetic information. The problem arises when common hard tissue data points are limited or non-existent such as in complete arch cases in which the 3D model of the complete arch provisional restorations must be aligned perfectly with the 3D model of the complete arch preparations. In these instances, soft tissue is not enough to ensure an accurate automatic or manual alignment due to a lack of well-defined reference points. A new technique is proposed for the proper digital alignment of the 3D virtual model of the provisional prosthetic to the 3D virtual model of the prepared teeth in cases where common and coincident hard tissue data points are limited. Clinical considerations: A technique is described in which fiducial composite resin dots are temporarily placed on the intraoral keratinized tissue in strategic locations prior to final impressions. These fiducial dots provide coincident and clear 3D data points that when scanned into a digital impression allow superimposition of the 3D models. Composite resin dots on keratinized tissue were successful at allowing accurate merging of provisional restoration and post-preparation 3D models for the purpose of using the provisional restorations as a guide for final CLINICAL SIGNIFICANCE: Composite resin dots placed temporarily on attached tissue were successful at allowing accurate merging of the provisional restoration 3D models to the preparation 3D models for the purposes of using the provisional restorations as a guide for final restoration design and manufacturing. In this case, they allowed precise superimposition of the 3D models made in the absence of any other hard tissue reference points, resulting in the fabrication of ideal final restorations. © 2017 Wiley Periodicals, Inc.

  14. An estimation of the percentage of dose in intraoral radiology exams using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Bonzoumet, S.P.J.; Braz, D.; Lopes, R.T.; Anjos, M.J.; Universidade do Estado do Rio de Janeiro; Padilha, Lucas

    2005-01-01

    In this work we used the EGS4 code in a simulated study of dose percentage in intraoral examination to 10 energy range to 140 keV. The simulation was carried out on a model consisting of different geometry (cheek, tooth and mouth cavity) under normal incidence X-ray beam over the surface of the various simulated materials. It was observed that for energy smaller than 30 keV most of the energy is deposited on the cheek. In 30 keV there is a point of maximum radiation absorption in the tooth (approximately 60% of the energy of the incident radiation is deposited on the tooth) in relation to other simulated materials. It means that in this energy there is a better contrast in the radiographic image of the tooth and a smaller dose on the cheek. In 40 keV the deposited energy in the tooth is roughly equal to the energy that is transmitted (to the radiographic film or buccal cavity) causing a degradation in the radiographic image and/or a higher dose in the oral cavity. For energies above 40 keV, the amount of energy transmitted (to the oral cavity and/or radiographic film) is higher than the energy deposited in other materials, i.e, it only contributes to increasing of dose in the regions close to the oral cavity and the radiographic image degradation. These results can provide important information for radiological procedures applied in dentistry where the image quality is a relevant factor to a dental evaluation needs as well as reducing dose in the oral cavity.

  15. Optimum image compression rate maintaining diagnostic image quality of digital intraoral radiographs

    International Nuclear Information System (INIS)

    Song, Ju Seop; Koh, Kwang Joon

    2000-01-01

    The aims of the present study are to determine the optimum compression rate in terms of file size reduction and diagnostic quality of the images after compression and evaluate the transmission speed of original or each compressed images. The material consisted of 24 extracted human premolars and molars. The occlusal surfaces and proximal surfaces of the teeth had a clinical disease spectrum that ranged from sound to varying degrees of fissure discoloration and cavitation. The images from Digora system were exported in TIFF and the images from conventional intraoral film were scanned and digitalized in TIFF by Nikon SF-200 scanner(Nikon, Japan). And six compression factors were chosen and applied on the basis of the results from a pilot study. The total number of images to be assessed were 336. Three radiologists assessed the occlusal and proximal surfaces of the teeth with 5-rank scale. Finally diagnosed as either sound or carious lesion by one expert oral pathologist. And sensitivity and specificity and kappa value for diagnostic agreement was calculated. Also the area (Az) values under the ROC curve were calculated and paired t-test and oneway ANOVA test was performed. Thereafter, transmission time of the image files of the each compression level were compared with that of the original image files. No significant difference was found between original and the corresponding images up to 7% (1:14) compression ratio for both the occlusal and proximal caries (p<0.05). JPEG3 (1:14) image files are transmitted fast more than 10 times, maintained diagnostic information in image, compared with original image files. 1:14 compressed image file may be used instead of the original image and reduce storage needs and transmission time.

  16. Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner.

    Science.gov (United States)

    Müller, Philipp; Ender, Andreas; Joda, Tim; Katsoulis, Joannis

    2016-04-01

    Little information is available on the impact of different scan strategies on the accuracy of full-arch scans with intraoral scanners. The aim of this in-vitro study was to investigate the trueness and precision of full-arch maxillary digital impressions comparing three scan strategies. Three scan strategies (A, B, and C) were applied each five times on one single model (A, first buccal surfaces, return from occlusal-palatal; B, first occlusal-palatal, return buccal; C, S-type one-way). The TRIOS Pod scanner (3shape, Copenhagen, Denmark) with a color detector was used for these digital impressions. A cast of a maxillary dentate jaw was fabricated and scanned with an industrial reference scanner. This full-arch data record was digitally superimposed with the test scans (trueness) and within-group comparison was performed for each group (precision). The values within the 90/10 percentiles from the digital superimposition were used for calculation and group comparisons with nonparametric tests (ANOVA, post-hoc Bonferroni). The trueness (mean ± standard deviation) was 17.9 ± 16.4 μm for scan strategy A, 17.1 ± 13.7 μm for B, and 26.8 ± 14.7 μm for C without statistically significant difference. The precision was lowest for scan strategy A (35.0 ± 51.1 μm) and significantly different to B (7.9 ± 5.6 μm) and C (8.5 ± 6.3 μm). Scan strategy B may be recommended as it provides the highest trueness and precision in full-arch scans and therefore minimizes inaccuracies in the final reconstruction.

  17. Comparison of Accuracy Between a Conventional and Two Digital Intraoral Impression Techniques.

    Science.gov (United States)

    Malik, Junaid; Rodriguez, Jose; Weisbloom, Michael; Petridis, Haralampos

    To compare the accuracy (ie, precision and trueness) of full-arch impressions fabricated using either a conventional polyvinyl siloxane (PVS) material or one of two intraoral optical scanners. Full-arch impressions of a reference model were obtained using addition silicone impression material (Aquasil Ultra; Dentsply Caulk) and two optical scanners (Trios, 3Shape, and CEREC Omnicam, Sirona). Surface matching software (Geomagic Control, 3D Systems) was used to superimpose the scans within groups to determine the mean deviations in precision and trueness (μm) between the scans, which were calculated for each group and compared statistically using one-way analysis of variance with post hoc Bonferroni (trueness) and Games-Howell (precision) tests (IBM SPSS ver 24, IBM UK). Qualitative analysis was also carried out from three-dimensional maps of differences between scans. Means and standard deviations (SD) of deviations in precision for conventional, Trios, and Omnicam groups were 21.7 (± 5.4), 49.9 (± 18.3), and 36.5 (± 11.12) μm, respectively. Means and SDs for deviations in trueness were 24.3 (± 5.7), 87.1 (± 7.9), and 80.3 (± 12.1) μm, respectively. The conventional impression showed statistically significantly improved mean precision (P < .006) and mean trueness (P < .001) compared to both digital impression procedures. There were no statistically significant differences in precision (P = .153) or trueness (P = .757) between the digital impressions. The qualitative analysis revealed local deviations along the palatal surfaces of the molars and incisal edges of the anterior teeth of < 100 μm. Conventional full-arch PVS impressions exhibited improved mean accuracy compared to two direct optical scanners. No significant differences were found between the two digital impression methods.

  18. Bilateral tumors of the upper urothelium

    Directory of Open Access Journals (Sweden)

    Đokić Milan

    2006-01-01

    Full Text Available Introduction: The incidence of tumors of the upper urothelium is high in our country, apart from their relation to specific regions (BEN and PBEN and their frequent bilateralism. Bilateral forms are present in significant percentage and are followed, in most cases, by renal failure, which speaks in favor of conservative surgery, if possible. Objective: The aim of the study was to present epidemiological, pathoanatomical and clinical characteristics of bilateral tumors of the upper urothelium and evaluate the Results of their treatment. Method: Our retrospective study analyzed 12 patients with bilateral tumors of the upper urothelium who were treated in the period from 1992 to 1996, according to their epidemiological, clinical, pathoanatomical and pathohistological characteristics, type of surgical treatment and relevant success. Results: In the observed period, bilateral tumors of the upper urothelium were found in 8.2% of our patients. In the group of 12 patients, 5 females and 7 males, 11 cases were from the region of Balkan Endemic Nephropathy (BEN. Renal failure was recorded in high percentage (66%. Radical surgical treatment - total nephroureterectomy was performed in 9 kidney units, and conservative operation in 15 units. Relapse significantly depended on tumor stage and grade, not on type of surgical treatment in the majority of cases. Five-year survival was 58.33%; major cause of death was associated with further evolution of tumor, recurrence and tumor dissemination, respectively, while renal failure complications were the cause of death in one case. Conclusion: The success of treatment mainly depends on tumor stage and grade and not on type of surgical Method in conservative treatment, but renal failure and its complications are an important risk factor in these patients.

  19. Measurement of scattered and transmitted X-rays from intra-oral and panoramic dental X-ray equipment.

    Science.gov (United States)

    Holroyd, John Richard

    2018-04-10

    To quantify the levels of transmitted radiation arising from the use of intra-oral dental X-ray equipment and scattered radiation arising from the use of both intra-oral and panoramic X-ray equipment. Methods: Levels of scattered radiation were measured at 1 m from a phantom, using an 1800 cc ion chamber. Transmitted radiation was measured using both: i) a phantom and Dose Area Product (DAP) meter, ii) a patient and an 1800 cc ion chamber. Results: For intra-oral radiography the patient study gave a maximum transmission of 1.80% (range 0.04% to 1.80%, mean 0.26%) and the phantom study gave a maximum transmission of 6% (range 2% to 6%, mean 5%). The maximum scattered radiation, per unit DAP, was 5.5 nGy (mGy cm2)-1 at 70 kVp and a distance of 1 m. For panoramic radiography the maximum scattered radiation was 9.3 nGy (mGy cm2)-1 at 80 kVp and a distance of 1 m. Conclusions: Typical doses from scattered and transmitted radiation in modern dental practice have been measured and values are presented to enable the calculation of adequate protection measures for dental radiography rooms. Advances in knowledge: Previous studies have used a phantom and measured radiation doses at 1 m from the phantom to determine the radiation dose transmitted through a patient, whereas this study uses both patient and phantom measurements together with a large area dose meter, positioned to capture the entire X-ray beam, to ensure more realistic dose measurements can be made. © 2018 IOP Publishing Ltd.

  20. Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible.

    Science.gov (United States)

    Hayama, Hironari; Fueki, Kenji; Wadachi, Juro; Wakabayashi, Noriyuki

    2018-03-01

    It remains unclear whether digital impressions obtained using an intraoral scanner are sufficiently accurate for use in fabrication of removable partial dentures. We therefore compared the trueness and precision between conventional and digital impressions in the partially edentulous mandible. Mandibular Kennedy Class I and III models with soft silicone simulated-mucosa placed on the residual edentulous ridge were used. The reference models were converted to standard triangulated language (STL) file format using an extraoral scanner. Digital impressions were obtained using an intraoral scanner with a large or small scanning head, and converted to STL files. For conventional impressions, pressure impressions of the reference models were made and working casts fabricated using modified dental stone; these were converted to STL file format using an extraoral scanner. Conversion to STL file format was performed 5 times for each method. Trueness and precision were evaluated by deviation analysis using three-dimensional image processing software. Digital impressions had superior trueness (54-108μm), but inferior precision (100-121μm) compared to conventional impressions (trueness 122-157μm, precision 52-119μm). The larger intraoral scanning head showed better trueness and precision than the smaller head, and on average required fewer scanned images of digital impressions than the smaller head (pdigital impressions. Digital impressions are partially comparable to conventional impressions in terms of accuracy; the use of a larger scanning head may improve the accuracy for removable partial denture fabrication. Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  1. Clinical marginal fit of zirconia crowns and patients' preferences for impression techniques using intraoral digital scanner versus polyvinyl siloxane material.

    Science.gov (United States)

    Sakornwimon, Nawapat; Leevailoj, Chalermpol

    2017-09-01

    The use of digital intraoral scanners is increasing; however, evidence of its precision in making crown impressions clinically remains scarce. Patients should also feel more comfortable with digital impressions, but only a few studies evaluating this subject have been performed. The purpose of this clinical study was to evaluate the marginal fit of monolithic zirconia crowns and patients' preferences for digital impressions versus polyvinyl siloxane (PVS) impressions. Sixteen participants with indications for single molar crowns were included. After crown preparation, digital impressions by intraoral scanner and PVS impressions were made. The participants were asked to complete a 6-item questionnaire with a visual analog scale related to perceptions of each of the following topics: time involved, taste/smell, occlusal registration, size of impression tray/scanner, gag reflex, and overall preference. Computer-aided design and computer-aided manufacturing monolithic zirconia crowns were fabricated from both impressions. The crowns were evaluated intraorally, and a blinded examiner measured the marginal discrepancy of silicone replicas under a stereomicroscope. Intraexaminer reliability was evaluated by calculating the intraclass correlation coefficient. Data for patients' preferences and marginal discrepancies were analyzed using the paired t test (α=.05). Visual analog scale scores for digital impressions were statistically significantly higher than those for PVS impressions in every topic (Pdigital group on all sides (P>.05). No differences were found in the clinical marginal fit of zirconia crowns fabricated from either digital impressions compared with PVS impressions. Furthermore, patients' satisfaction with digital impressions was significantly higher than with conventional impressions. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Bilateral Facial Paralysis Caused by Bilateral Temporal Bone Fracture: A Case Report and a Literature Review

    Directory of Open Access Journals (Sweden)

    Sultan Şevik Eliçora

    2015-01-01

    Full Text Available Bilateral facial paralysis caused by bilateral temporal bone fracture is a rare clinical entity, with seven cases reported in the literature to date. In this paper, we describe a 40-year-old male patient with bilateral facial paralysis and hearing loss that developed after an occupational accident. On physical examination, House-Brackmann (HB facial paralysis of grade 6 was observed on the right side and HB grade 5 paralysis on the left. Upon temporal bone computed tomography (CT examination, a fracture line exhibiting transverse progression was observed in both petrous temporal bones. Our patient underwent transmastoid facial decompression surgery of the right ear. The patient refused a left-side operation. Such patients require extensive monitoring in intensive care units because the presence of multiple injuries means that facial functions are often very difficult to evaluate. Therefore, delays may ensue in both diagnosis and treatment of bilateral facial paralysis.

  3. Random Pattern Vertically Oriented, Partial Thickness Buccinator Myomucosal Flap for Intraoral Reconstruction: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Amin Rahpeyma

    2016-05-01

    Full Text Available Introduction: Reconstruction of the oral cavity witha flap design containing the buccal mucosa and buccinator muscle but excluding the facial artery and vein is the topic of these case reports. Case Reports: This article uses random pattern vertically oriented partial thickness buccinator myomucosal flap for intraoral reconstruction in two cases. The first was for lining the mandibular anterior vestibule in a trauma patient. The second was for oral side coverage of bone graft in special cleft patient. In both patients, this flap survived and good bone coverage with non-keratinized mucosa was obtained. Conclusion:  Thin long buccal myomucosal flap not including facial artery and vein can survive.

  4. Stereologic, histopathologic, flow cytometric, and clinical parameters in the prognostic evaluation of 74 patients with intraoral squamous cell carcinomas

    DEFF Research Database (Denmark)

    Bundgaard, T; Sørensen, Flemming Brandt; Gaihede, M

    1992-01-01

    , tumor size, and the TNM classification. RESULTS: The investigation showed a significant difference between the volume-weighted mean nuclear volume (nuclear vv) of oral leukoplakia (n = 29) and oral squamous cell carcinomas (P = 0.001). The value of the parameters as prognostic indicators of survival......BACKGROUND AND METHODS: A consecutive series of all 78 incident cases of intraoral squamous cell carcinoma occurring during a 2-year period in a population of 1.4 million inhabitants were evaluated by histologic score (the modified classification of Jacobsson et al.), flow cytometry, stereology...

  5. Chairside treatment of amelogenesis imperfecta, including establishment of a new vertical dimension with resin nanoceramic and intraoral scanning.

    Science.gov (United States)

    Zimmermann, Moritz; Koller, Christina; Hickel, Reinhard; Kühnisch, Jan

    2016-09-01

    Amelogenesis imperfecta is a hereditary disease affecting the structural development of tooth substance. This clinical report describes a 1-visit chairside treatment of an 8-year-old patient with amelogenesis imperfecta, using computer-aided design and computer-aided manufacturing (CAD-CAM) technology. Intraoral scanning was performed using the Cerec Omnicam. Thirteen resin nanoceramic crowns (Lava Ultimate) were fabricated chairside by using a Cerec MCXL milling unit and seated adhesively. The patient's treatment included establishing a new occlusal vertical dimension and new centric relationship. Reevaluation after 6 months showed a stable situation. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Comparison of caries detection methods using varying numbers of intra-oral digital photographs with visual examination for epidemiology in children

    Science.gov (United States)

    2013-01-01

    Background This was a method comparison study. The aim of study was to compare caries information obtained from a full mouth visual examination using the method developed by the British Association for the Study of Community Dentistry (BASCD) for epidemiological surveys with caries data obtained from eight, six and four intra-oral digital photographs of index teeth in two groups of children aged 5 years and 10/11 years. Methods Five trained and calibrated examiners visually examined the whole mouth of 240 5-year-olds and 250 10-/11-year-olds using the BASCD method. The children also had intra-oral digital photographs taken of index teeth. The same 5 examiners assessed the intra-oral digital photographs (in groups of 8, 6 and 4 intra-oral photographs) for caries using the BASCD criteria; dmft/DMFT were used to compute Weighted Kappa Statistic as a measure of intra-examiner reliability and intra-class correlation coefficients as a measure of inter-examiner reliability for each method. A method comparison analysis was performed to determine the 95% limits of agreement for all five examiners, comparing the visual examination method with the photographic assessment method using 8, 6 and 4 intra-oral photographs. Results The intra-rater reliability for the visual examinations ranged from 0.81 to 0.94 in the 5-year-olds and 0.90 to 0.97 in the 10-/11-year-olds. Those for the photographic assessments in the 5-year-olds were for 8 intra-oral photographs, 0.86 to 0.94, for 6 intra-oral photographs, 0.85 to 0.98 and for 4 intra-oral photographs, 0.80 to 0.96; for the 10-/11-year-olds were for 8 intra-oral photographs 0.84 to 1.00, for 6 intra-oral photographs 0.82 to 1.00 and for 4 intra-oral photographs 0.72 to 0.98. The 95% limits of agreement were −1.997 to 1.967, -2.375 to 2.735 and −2.250 to 2.921 respectively for the 5-year-olds and −2.614 to 2.027, -2.179 to 3.887 and −2.594 to 2.163 respectively for the 10-/11-year-olds. Conclusions The photographic

  7. Using Intraoral Scanning Technology for Three-Dimensional Printing of Kennedy Class I Removable Partial Denture Metal Framework: A Clinical Report.

    Science.gov (United States)

    Hu, Feng; Pei, Zhenhua; Wen, Ying

    2017-11-16

    Removable partial dentures (RPDs) are used to restore missing teeth and are traditionally fabricated using the lost-wax casting technique. The casting process is arduous, time-consuming, and requires a skilled technician. The development of intraoral scanning and 3D printing technology has made rapid prototyping of the RPD more achievable. This article reports a completed case of direct fabrication of a maxillary RPD metal framework (Kennedy Class I) using intraoral scanning and 3D printing techniques. Acceptable fit and satisfactory clinical outcome were demonstrated. Intraoral scanning and 3D printing for fabrication of the RPD metal framework is a useful alternative to conventional impression and casting techniques, especially for patients suffering from nasal obstruction or intolerance. © 2017 by the American College of Prosthodontists.

  8. Unusual Presentation of Recurrent Pyogenic Bilateral Psoas Abscess Causing Bilateral Pulmonary Embolism by Iliac Vein Compression

    OpenAIRE

    Ijaz, Mohsin; Sakam, Sailaja; Ashraf, Umair; Marquez, Jose Gomez

    2015-01-01

    Patient: Male, 47 Final Diagnosis: Bilateral psoas abscess • acute lower extremity deep vein thrombosis • bilateral pulmonary embolism Symptoms: Progressive left leg swelling • productive cough with whitish sputum • right flank pain Medication: Antibiotics and anticoagulation Clinical Procedure: CT-guided percutaneous drain placement Specialty: Internal Medicine/Critical Care Objective: Unusual presentation Background: Psoas abscesses are a known cause of back pain, but they have not been rep...

  9. Hardware Implementation of a Bilateral Subtraction Filter

    Science.gov (United States)

    Huertas, Andres; Watson, Robert; Villalpando, Carlos; Goldberg, Steven

    2009-01-01

    A bilateral subtraction filter has been implemented as a hardware module in the form of a field-programmable gate array (FPGA). In general, a bilateral subtraction filter is a key subsystem of a high-quality stereoscopic machine vision system that utilizes images that are large and/or dense. Bilateral subtraction filters have been implemented in software on general-purpose computers, but the processing speeds attainable in this way even on computers containing the fastest processors are insufficient for real-time applications. The present FPGA bilateral subtraction filter is intended to accelerate processing to real-time speed and to be a prototype of a link in a stereoscopic-machine- vision processing chain, now under development, that would process large and/or dense images in real time and would be implemented in an FPGA. In terms that are necessarily oversimplified for the sake of brevity, a bilateral subtraction filter is a smoothing, edge-preserving filter for suppressing low-frequency noise. The filter operation amounts to replacing the value for each pixel with a weighted average of the values of that pixel and the neighboring pixels in a predefined neighborhood or window (e.g., a 9 9 window). The filter weights depend partly on pixel values and partly on the window size. The present FPGA implementation of a bilateral subtraction filter utilizes a 9 9 window. This implementation was designed to take advantage of the ability to do many of the component computations in parallel pipelines to enable processing of image data at the rate at which they are generated. The filter can be considered to be divided into the following parts (see figure): a) An image pixel pipeline with a 9 9- pixel window generator, b) An array of processing elements; c) An adder tree; d) A smoothing-and-delaying unit; and e) A subtraction unit. After each 9 9 window is created, the affected pixel data are fed to the processing elements. Each processing element is fed the pixel value for

  10. Videojuego con Realidad Virtual

    OpenAIRE

    González Mora, César

    2017-01-01

    El objetivo del proyecto es el desarrollo de un videojuego deportivo que utilice realidad mixta. El videojuego se podrá utilizar con dispositivos de tipo cardboard, y utilizará realidad aumentada para la interacción del jugador con el videojuego. En el desarrollo se utilizará el motor Unity para conseguir una aplicación multiplataforma, y la librería Vuforia para implementar realidad mixta.

  11. Sistemas integrados con Arduino

    OpenAIRE

    EL YAKOUTI, MOHAMMED

    2017-01-01

    Design of a robot prototype remotely controllable from Bluetooth using Arduino. Control and testing of sensors and events interacting with Arduino and Bluetooth. Diseño de un prototipo de robot controlable remotamente con Bluetooth utilizando Arduino. Control y verificación de los sensores y eventos que interactúan mediante el Arduino y el Bluetooth. El Yakouti, M. (2017). Sistemas integrados con Arduino. http://hdl.handle.net/10251/89274. TFGM

  12. Investigando con personas con dificultades de aprendizaje

    Directory of Open Access Journals (Sweden)

    Borja González Luna

    2013-12-01

    Full Text Available El artículo muestra los orígenes de lo que Walmsley (2008 denomina «investigación inclusiva». Para comprender qué se entiende por investigación inclusiva tenemos que remontarnos a los debates epistemológicos sobre las metodologías cuantitativas y cualitativas, acontecidos en la década de los 90, en torno a la revista Disability & Society. A partir de una síntesis de dichos debates, focalizados en el ámbito de la «discapacidad intelectual y del desarrollo», se exponen dos estrategias de colaboración con dicha población: a una aproximación etnográfica (de trabajo grupal, y b una aproximación biográfica (de trabajo individual. A continuación se esboza un posible diseño de trabajo de campo que intenta superar el paradigma cualitativo «clásico» con el objetivo de incluir a dicho colectivo más allá del rol de «sujetos de la investigación». Para finalizar se recoge el debate sobre la accesibilidad de los resultados de la investigación a los participantes en dichas investigaciones, y con ello la necesaria innovación en el ámbito de las «devoluciones» de los resultados, cuando se trata de incluir a personas que presentan limitaciones para la comprensión del lenguaje abstracto oral y/o escrito.

  13. Bilateral low-density lesions in the internal capsule, with con- firmed ...

    African Journals Online (AJOL)

    Enrique

    SA JOURNAL OF RADIOLOGY • May 2004. Case study 1. CNS toxoplasmosis. A 34-year-old known immuno- compromised female patient present- ed with fever of unknown origin and expressive apraxia. She was also on anti TB treatment for pulmonary TB. On clinical examination she was found to have a fever of 39°C, ...

  14. Var??n de 30 a??os con dolor pretibial bilateral

    OpenAIRE

    Vargas-Hitos, Jos?? Antonio; Garc??a-Castro, Jos?? Miguel; Ja??n- ??guila, Fernando; Jim??nez-Alonso, Juan

    2012-01-01

    Var??n de 30 a??os que consultaba por dolor intenso y progresivo de dos meses de evoluci??n localizado en la cara anterior y distal de ambas piernas sin factor desencadenante aparente y mala respuesta a tratamiento analg??sico convencional. El paciente negaba otros s??ntomas a excepci??n de un rash eritematoso no pruriginoso generalizado que hab??a afectado tronco, palmas y plantas y que hab??a sido considerado como una reacci??n de hipersensibilidad a alguna de las medicaciones p...

  15. Bilateral cerebellar activation in unilaterally challenged essential tremor

    Directory of Open Access Journals (Sweden)

    Marja Broersma

    2016-01-01

    Conclusions: Our results expand on previous findings of bilateral cerebellar involvement in ET. We have identified specific areas in the bilateral somatomotor regions of the cerebellum: lobules V, VI and VIII.

  16. Bilateral primary adrenocortical carcinoma complicated by Addisonian crisis: case report

    International Nuclear Information System (INIS)

    Foster, M.; Nolan, R.L.; Hong, H.H.

    2001-01-01

    Primary adrenal carcinoma is a rare malignancy. Primary adrenal insufficiency (i.e. Addison's disease) is a rare complication of bilateral infiltration. We report a case of primary bilateral adrenal carcinoma complicated by an episode of primary adrenal insufficiency. (author)

  17. Bilateral spontaneous pneumothorax with pulmonary metastases of synovial sarcoma

    International Nuclear Information System (INIS)

    Matushita, J.P.K.; Azevedo, C.M. de

    1989-01-01

    The association of bilateral spontaneous pneumothorax with pulmonary tumor is uncommon and with pulmonary metastases is rare. The clinical and radiological features of bilateral spontaneous pneumothorax from a synovial sarcoma in a 14 years old boy are described. (author) [pt

  18. Bilateral Diabetic Papillopathy and Metabolic Control

    DEFF Research Database (Denmark)

    Ostri, Christoffer; Lund-Andersen, Henrik; Sander, Birgit

    2010-01-01

    OBJECTIVE: The pathogenesis of diabetic papillopathy largely is unknown, but case reports suggest that it may follow rapidly improved metabolic control. The present study was designed to investigate this hypothesis. DESIGN: Retrospective case-control study. PARTICIPANTS: Two thousand sixty......-six patients with type 1 diabetes. METHODS: Review of clinical, photographic, and clinical chemistry records from a large diabetology and ophthalmology unit between 2001 and 2008. MAIN OUTCOME MEASURES: Simultaneous, bilateral diabetic papillopathy. RESULTS: The mean follow-up was 4.9 years. During 10 020...... patient-years of observation, bilateral diabetic papillopathy developed in 5 patients. During the year preceding this incident, all 5 patients had experienced a decrease in glycosylated hemoglobin A(1c) (HbA(1C)) at a maximum rate of -2.5 (mean) percentage points per quarter year, which was significantly...

  19. Sudden bilateral hearing loss after organophosphate inhalation

    Directory of Open Access Journals (Sweden)

    Mehmet Akif Dundar

    2016-12-01

    Full Text Available Sudden bilateral hearing loss are seen rarely and the toxic substance exposure constitutes a small part of etiology. A Fifty-eight-year-old woman admitted to our clinic with sudden bilateral hearing loss shortly after chlorpyrifos-ethyl exposure. Otolaryngologic examination findings were normal. The patient had 40 dB sensorineural hearing loss (SNHL on the right ear and 48 dB SNHL on the left ear. Additional diagnostic tests were normal. The conventional treatment for sudden hearing loss was performed. On the second week following organophosphate (OP exposure the patient's hearing loss almost completely resolved. OP's are heavily used in agriculture and should be taken into consideration as an etiologic factor in sudden hearing loss. Keywords: Organophosphates, Hearing loss, Sudden

  20. Bilateral akillesseneruptur efter behandling med ciprofloxacin

    DEFF Research Database (Denmark)

    Attarzadeh, Amir Pasha; Ryge, Camilla

    2013-01-01

    We report a case of spontaneous non-traumatic bilateral rupture of the Achilles tendons following ciprofloxacin treatment. A 54-year-old man presented with spontaneous Achilles tendon rupture on the left side, tendinitis and partial tear on the right side following few days of treatment with cipr......We report a case of spontaneous non-traumatic bilateral rupture of the Achilles tendons following ciprofloxacin treatment. A 54-year-old man presented with spontaneous Achilles tendon rupture on the left side, tendinitis and partial tear on the right side following few days of treatment...... with ciprofloxacin 500 mg twice daily and long-term treatment with prednisolon 10 mg once daily. This rare side effect caused by concurrent treatment with steroids and ciprofloxacin should be kept in mind. Any signs of tendinitis following this treatment should arouse the physicians' suspicion towards ciprofloxacin....

  1. Bilateral Elastofibroma Dorsi: A Case Report

    Directory of Open Access Journals (Sweden)

    Burçin Çelik

    2010-09-01

    Full Text Available Elastofibroma dorsi is a rare, slow-growing soſt tissue tumor of the chest wall. The tumor typically located under the lower pole of the scapula. A 57-year-old woman who had retiredas a teacher, presented with a 1-year history of pain on the back and with a 3-month history of swelling located under the leſt scapula. Computed tomography and magnetic resonance imaging showed bilateral, solid soſt tissue tumors under the scapula. She underwent total resection of the tumor on the leſt side. Tumor was diagnosed histopathologically as elastofibroma. Elastofibroma dorsi can be undetermined because of its localization. Radiological examination is important especially on diagnosis of bilateral localization.

  2. Bilateral cerebrovascular accidents in incontinentia pigmenti.

    Science.gov (United States)

    Fiorillo, Loretta; Sinclair, D Barry; O'Byrne, Mary L; Krol, Alfons L

    2003-07-01

    Incontinentia Pigmenti is an X-linked dominant neurocutaneous disorder with central nervous system manifestations in 30% of cases, including seizures and mental retardation. Ischemic or hemorrhagic cerebrovascular accidents have been reported rarely in incontinentia pigmenti. Chart review and literature search was performed following identification of the index case. We describe a patient with incontinentia pigmenti who developed bilateral cerebrovascular accidents in the neonatal period, with resultant severe neurologic sequelae. This is the second reported case of bilateral cerebrovascular accidents in a patient with incontinentia pigmenti. This finding may be secondary to cerebrovascular anomalies, similar to those observed in the retina. Recognition of cerebrovascular accidents as a complication of incontinentia pigmenti will hopefully lead to earlier recognition and treatment.

  3. Bilateral Pneumothoraces Following Central Venous Cannulation

    Science.gov (United States)

    Pazos, F.; Masterson, K.; Inan, C.; Robert, J.; Walder, B.

    2009-01-01

    We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right pleural space before cannulation of the right subclavian vein. After the procedure, the patient slowly became hemodynamically instable with respiratory distress. A chest radiograph revealed a complete left-side pneumothorax and a mild right-side pneumothorax. The right-side pneumothorax became under tension after left chest tube insertion. The symptoms finally resolved after insertion of a right chest tube. After a diagnostic work-up, we suspect a congenital “Buffalo chests” explaining bilateral pneumothoraces and a secondary tension pneumothorax. PMID:19901997

  4. Bilateral metachronous periosteal tibial amyloid tumors

    International Nuclear Information System (INIS)

    Murata, H.; Kusuzaki, Katsuyuki; Hashiguchi, S.; Ueda, Hidetaka; Hirasawa, Yasusuke

    2000-01-01

    Localized primary periosteal amyloid tumors are extremely rare. A case of bilateral tibial amyloid tumor is presented. A 62-year-old woman initially presented with a painful mass in the anterior aspect of the right leg. There was no evidence of underlying systemic disease, including chronic infection or malignancy. Based on the results of resistance with Congo red staining to treatment with potassium permanganate and positivity for kappa light chain, we classified this particular case as AL-type amyloidosis. The patient noticed a swelling in the opposite leg 2 years later. The second tumor was also an AL-type amyloidoma. Amyloid tumors are generally solitary. This is the first case of bilateral periosteal amyloid tumors of the AL-type occurring in the tibiae. (orig.)

  5. Bilateral breast cancer after cured Hodgkin's disease

    International Nuclear Information System (INIS)

    Anderson, N.; Lokich, J.

    1990-01-01

    Three patients developed bilateral breast cancer at 10 to 24 years after mantle irradiation for locally or systemically advanced Hodgkin's disease (HD). Four of the six cancers in the three patients were detected only by mammography. Pathologically, five of the cancers were intraductal carcinomas (four with an invasive component) with one being a lobular carcinoma. Five of the six lesions were Stage I pathologically without evidence of axillary nodal involvement. It is recommended that female patients with Hodgkin's disease who have received mantle irradiation as part of the therapy for their Hodgkin's disease and who are observed for 10 or more years after completion of mantle irradiation be considered at risk for the development of breast cancer. Such patients should be monitored appropriately by routine bilateral mammograms to increase the early detection of early stage lesions

  6. Symptomatic bilateral xanthogranuloma of the choroid plexus

    Directory of Open Access Journals (Sweden)

    Selin Tural Emon

    2017-01-01

    Full Text Available Xanthogranulomas (XGRs of the choroid plexus are rare, asymptomatic, and benign lesions usually found incidentally. Here, we present a case of a 47-year-old male with bilateral XGR of the choroid plexus with periventricular edema and discuss our case in relation to a review of existing literature pertaining to the radiology of XGRs. To the best of our knowledge, this is the first reported case of bilateral trigonal XGR causing brain edema without ventricular dilatation. Despite the fact that they can cause hydrocephalus, XGRs are silent and benign lesions. Although the etiopathology of XGRs remains poorly understood, enhanced imaging analyses may provide additional information regarding edema and focal white matter signal changes.

  7. Bilateral Nongranulomatous Uveitis with Infective Endocarditis

    OpenAIRE

    Ha, Sang Won; Shin, Jae Pil; Kim, Si Yeol; Park, Dong Ho

    2012-01-01

    A 32-year-old male who had infective endocarditis complained of photophobia and blurred vision in both eyes. Biomicroscopic examination and fundus examination revealed anterior chamber reaction, vitritis, optic disc swelling, and Roth spots. He was diagnosed with bilateral nongranulomatous uveitis and treated with topical steroid eye drops and posterior sub-Tenon injection of triamcinolone. His visual symptoms were resolved within 1 week, and inflammation resolved within 4 weeks after treatment.

  8. Bilateral nongranulomatous uveitis with infective endocarditis.

    Science.gov (United States)

    Ha, Sang Won; Shin, Jae Pil; Kim, Si Yeol; Park, Dong Ho

    2013-02-01

    A 32-year-old male who had infective endocarditis complained of photophobia and blurred vision in both eyes. Biomicroscopic examination and fundus examination revealed anterior chamber reaction, vitritis, optic disc swelling, and Roth spots. He was diagnosed with bilateral nongranulomatous uveitis and treated with topical steroid eye drops and posterior sub-Tenon injection of triamcinolone. His visual symptoms were resolved within 1 week, and inflammation resolved within 4 weeks after treatment.

  9. Bilateral Pneumothoraces Following Central Venous Cannulation

    OpenAIRE

    Pazos, F.; Masterson, K.; Inan, C.; Robert, J.; Walder, B.

    2009-01-01

    We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right ...

  10. Bilateral primary malignant lymphoma of the breast.

    Science.gov (United States)

    Shpitz, B; Witz, M; Kaufman, Z; Griffel, B; Manor, Y; Dinbar, A

    1985-08-01

    A rare case of bilateral primary malignant lymphoma of breast in a 76 year old woman is presented. The lesion was examined by electron microscopy and immunochemistry. The diagnosis of primary malignant lymphoma remains a diagnosis by exclusion and requires extensive work-up to exclude widespread malignant process. The behaviour of this malignancy tends to be an aggressive one and the prognosis is generally poor.

  11. BILATERAL SAGITAL SPLIT OSTEOTOMY PADA MANDIBULA PROGNATI

    Directory of Open Access Journals (Sweden)

    Pradono Pradono

    2015-07-01

    Full Text Available A young girl 20 years old with mandibular prognathism, has been treated with orthodontics and surgical treatment in between. Mandibular set back was done intra orally 5 mm length and bilateral sagital split ramus osteotomy method. And rigid fixation was done by inserting three 2 mm bicortical screws for stabilizing the fragment. This method allowed the bony segments to heal properly and allowed the patients to function sooner.

  12. A rare case of bilateral aspergillus endophthalmitis

    Directory of Open Access Journals (Sweden)

    Saurabh Gupta

    2015-12-01

    Full Text Available Aspergillus endophthalmitis is a devastating inflammatory condition of the intraocular cavities that may result in irreparable loss of vision and rapid destruction of the eye. Almost all cases in the literature have shown an identified source causing aspergillus endophthalmitis as a result of direct extension of disease. We present a rare case of bilateral aspergillus endophthalmitis. A 72-year-old woman with a history of diabetes mellitus, congenital Hirschsprung disease, and recent culture-positive candida pyelonephritis with hydronephrosis status post-surgical stent placement presented with difficulty opening her eyes. She complained of decreased vision (20/200 with pain and redness in both eyes – right worse then left. Examination demonstrated multiple white fungal balls in both retinas consistent with bilateral fungal endophthalmitis. Bilateral vitreous taps for cultures and staining were performed. Patient was given intravitreal injections of amphotericin B, vancomycin, ceftazidime, and started on oral fluconazole. Patient was scheduled for vitrectomy to decrease organism burden and to remove loculated areas of infection that would not respond to systemic antifungal agents. Four weeks after initial presentation, the fungal cultures revealed mold growth consistent with aspergillus. Patient was subsequently started on voriconazole and fluconazole was discontinued due to poor efficacy against aspergillus. Further workup was conducted to evaluate for the source of infection and seeding. Transthoracic cardiogram was unremarkable for any vegetation or valvular abnormalities. MRI of the orbits and sinuses did not reveal any mass lesions or bony destruction. CT of the chest was unremarkable for infection. Aspergillus endophthalmitis may occur because of one of these several mechanisms: hematogenous dissemination, direct inoculation by trauma, and contamination during surgery. Our patient's cause of bilateral endophthalmitis was through an

  13. Framing effect following bilateral amygdala lesion

    OpenAIRE

    Talmi, Deborah; Hurlemann, Ren?; Patin, Alexandra; Dolan, Raymond J.

    2010-01-01

    A paradigmatic example of an emotional bias in decision making is the framing effect, where the manner in which a choice is posed ? as a potential loss or a potential gain ? systematically biases an ensuing decision. Two fMRI studies have shown that the activation in the amygdala is modulated by the framing effect. Here, contrary to an expectation based on these studies, we show that two patients with Urbach-Wiethe (UW) disease, a rare condition associated with congenital, complete bilateral ...

  14. [Bilateral ovarian Burkitt's lymphoma. A case presentation].

    Science.gov (United States)

    Briseño-Hernández, Andrés Alejandro; Quezada-López, Deissy Roxana; Castañeda-Chávez, Agar; Dassaejv Macías-Amezcua, Michel; Pintor-Belmontes, Julio Cesar

    2014-01-01

    Burkitt lymphoma, is described as an aggressive form of non-Hodgkin lymphoma of B cells which occurs most often in children and young adults, ovarian lymphoma can appear as a primary lesion or more commonly referred to as a metastasis. Primary ovarian lesions are rare manifestations corresponding to 0.5% of non-Hodgkin lymphoma and 1.5% of ovarian tumors. Clinic case: 31 years old female with general weakness, march incapacity, dyspnea, hyporexia, fever, diaphoresis, weight loss of 20 kg, flat abs with abdominal pain; Ca125 610 U/ml. Abdominal computed tomography shows a solid aspect tumor which affects the right pelvic cavity. Bilateral ovarian tumors were removed. Microscopically, both lesions show a "starry sky" pattern composed by a monotonous infiltration of lymphocytes mixed with large and clear macrophages, several atypical mitoses, and necrosis and hemorrhage areas. Immunohistochemistry was positive for CD10, CD20, and negative for CD3 and high Ki67 proliferation index. Bilateral ovarian Burkitt's lymphoma was diagnosed. Bilateral ovarian Burkitt's lymphoma is a rare entity, with a variability of presentations, the abdominal pain and abdominal tumors are the most frequent. The patient's prognosis at short term is poor, therefore it's necessary to know this entity and make an early diagnosis.

  15. Bilateral femoral neck fractures following pelvic irradiation

    International Nuclear Information System (INIS)

    Mitsuda, Kenji; Nishi, Hosei; Oba, Hiroshi

    1977-01-01

    Over 300 cases of femoral neck fractures following radiotherapy for intrapelvic malignant tumor have been reported in various countries since Baensch reported this disease in 1927. In Japan, 40 cases or so have been reported, and cases of bilateral femoral neck fractures have not reached to ten cases. The authors experienced a case of 75 year-old female who received radiotherapy for cancer of the uterus, and suffered from right femoral neck fracture 3 months after and left femoral neck fracture one year and half after. As clinical symptoms, she had not previous history of trauma in bilateral femurs, but she complained of a pain in a hip joint and of gait disturbance. The pain in left femoral neck continued for about one month before fracture was recognized with roentgenogram. As histopathological findings, increase of fat marrow, decrease of bone trabeculae, and its marked degeneration were recognized. Proliferation of some blood vessels was found out, but thickness of the internal membrane and thrombogenesis were not recognized. Treatment should be performed according to degree of displacement of fractures. In this case, artificial joint replacement surgery was performed to the side of fracture of this time, because this case was bilateral femoral neck fractures and the patient had received artificial head replacement surgery in the other side of fracture formerly. (Tsunoda, M.)

  16. A case misdiagnosed as bilateral abducens palsy

    International Nuclear Information System (INIS)

    Takeda, Naoya; Kuwamura, Keiichi; Shirataki, Kunio; Tamaki, Norihiko; Matsumoto, Satoshi

    1984-01-01

    A 66-year-old male was admitted to our neurosurgical floor because of double vision and gait disturbance. Neurological examinations revealed bilateral 6th nerve palsy with both eyes pointing toward the midline. Initially, using a tentative diagnosis of intracranial mass lesions, especially localized at the base of the skull, computerized tomography of the head, cerebral angiography, orbital venography, and metrizamide CT cisternography were performed; the findings were normal. An orbital CT scan showed an enlargement of the bilateral medial rectus muscles, and the thyroid functions of T 3 and T 4 and the T 3 uptake were all elevated, which was compatible with the diagnosis of Graves' disease. The limitations of both eyeballs were considered to be due not to the 6th nerve palsy, but to the hypertrophy of the bilateral medial rectus muscles. We neurosurgeons should recall Graves' disease as well as intracranial lesions, cerebrovascular disease, and post-traumatic sequelae when examining a patient who presents limitations of external ocular movement. (author)

  17. High Performance, Three-Dimensional Bilateral Filtering

    International Nuclear Information System (INIS)

    Bethel, E. Wes

    2008-01-01

    Image smoothing is a fundamental operation in computer vision and image processing. This work has two main thrusts: (1) implementation of a bilateral filter suitable for use in smoothing, or denoising, 3D volumetric data; (2) implementation of the 3D bilateral filter in three different parallelization models, along with parallel performance studies on two modern HPC architectures. Our bilateral filter formulation is based upon the work of Tomasi [11], but extended to 3D for use on volumetric data. Our three parallel implementations use POSIX threads, the Message Passing Interface (MPI), and Unified Parallel C (UPC), a Partitioned Global Address Space (PGAS) language. Our parallel performance studies, which were conducted on a Cray XT4 supercomputer and aquad-socket, quad-core Opteron workstation, show our algorithm to have near-perfect scalability up to 120 processors. Parallel algorithms, such as the one we present here, will have an increasingly important role for use in production visual analysis systems as the underlying computational platforms transition from single- to multi-core architectures in the future.

  18. High Performance, Three-Dimensional Bilateral Filtering

    Energy Technology Data Exchange (ETDEWEB)

    Bethel, E. Wes

    2008-06-05

    Image smoothing is a fundamental operation in computer vision and image processing. This work has two main thrusts: (1) implementation of a bilateral filter suitable for use in smoothing, or denoising, 3D volumetric data; (2) implementation of the 3D bilateral filter in three different parallelization models, along with parallel performance studies on two modern HPC architectures. Our bilateral filter formulation is based upon the work of Tomasi [11], but extended to 3D for use on volumetric data. Our three parallel implementations use POSIX threads, the Message Passing Interface (MPI), and Unified Parallel C (UPC), a Partitioned Global Address Space (PGAS) language. Our parallel performance studies, which were conducted on a Cray XT4 supercomputer and aquad-socket, quad-core Opteron workstation, show our algorithm to have near-perfect scalability up to 120 processors. Parallel algorithms, such as the one we present here, will have an increasingly important role for use in production visual analysis systems as the underlying computational platforms transition from single- to multi-core architectures in the future.

  19. [Bilateral traumatic patella fracture: a case report].

    Science.gov (United States)

    Cırpar, Meriç; Türker, Mehmet; Aslan, Arif; Yalçınozan, Mehmet

    2011-08-01

    Patellar fractures are uncommon injuries and account for approximately 1% of all fractures. In this article, a 35-year-old male patient who sustained a collision deceleration accident with bilateral comminuted transverse patellar fractures is presented. For this patient, open reduction and internal fixation with tension band technique, using two Kirschner wires and cerclage wire was applied for both fractures. At the first postoperative day, isometric quadriceps and active range of motion exercises were begun and the patient was allowed to walk full weight bearing with two crutches while both extremities were immobilized in a hinged brace allowing maximum 30 degrees of flexion. At postoperative fourth week brace immobilization was terminated. However, the patient was advised to use crutches for two weeks more to prevent any complications that may arise during walking because of the bilaterally of the injury. At six weeks solid union was achieved. During the last visit at postoperative second year, the patient had no complaints and the range of motion was full. In this paper a case of bilateral patella fractures is presented as a consequence of a dashboard injury, and the pathomechanical and therapeutical aspects of such an injury is discussed.

  20. Multilateral, regional and bilateral energy trade governance

    Energy Technology Data Exchange (ETDEWEB)

    Leal-Arcas, Rafael; Grasso, Costantino; Rios, Juan Alemany (Queen Mary Univ. of London (United Kingdom))

    2014-12-01

    The current international energy trade governance system is fragmented and multi-layered. Streamlining it for greater legal cohesiveness and international political and economic cooperation would promote global energy security. The current article explores three levels of energy trade governance: multilateral, regional and bilateral. Most energy-rich countries are part of the multilateral trading system, which is institutionalized by the World Trade Organization (WTO). The article analyzes the multilateral energy trade governance system by focusing on the WTO and energy transportation issues. Regionally, the article focuses on five major regional agreements and their energy-related aspects and examines the various causes that explain the proliferation of regional trade agreements, their compatibility with WTO law, and then provides several examples of regional energy trade governance throughout the world. When it comes to bilateral energy trade governance, this article only addresses the European Union’s (EU) bilateral energy trade relations. The article explores ways in which gaps could be filled and overlaps eliminated whilst remaining true to the high-level normative framework, concentrating on those measures that would enhance EU energy security.

  1. Bilateral ovarian fibroma associated with Gorlin syndrome

    Directory of Open Access Journals (Sweden)

    Shahnaz Aram

    2009-02-01

    Full Text Available

    • Gorlin syndrome (GS, also known as nevoid basal cell carcinoma syndrome (NBCCS, is a rare inherited multisystem disorder. This paper presents a 22-years-old Iranian woman with this syndrome whose past history was multiple keratocysts of maxillary bone. She was referred to gynecology clinic with the chief complaint of irregular menses and vaginal spotting. On examination, frontal bossing and hypertelorism were detected. Physical examination of genitalia disclosed bilateral adnexal masses. Pelvic ultrasound showed two solid, echogenous and calcified masses measuring 100*50*10 & 60*50*45 mm in the left and right ovaries, respectively. The patient underwent right oophorectomy and ovarian mass resection with preservation of intact ovarian tissue on the left side. On frozen and permanent histological sections, bilateral and calcified ovarian fibromas were diagnosed. Surprisingly, during the last follow-up one year after the surgery, we found that our patient was expecting a baby. It can be concluded that in the presence of bilateral and calcified ovarian fibromas, the possibility of GS should be considered. Accurate diagnosis is only possible with close attention to the familial and past medical history and physical examination. In these patients, careful follow up for detecting malignancies and other complications is highly recommended.
    • KEY WORDS: Gorlin syndrome, ovarian fibroma, multiple keratocysts.

  2. Cryptogenic organising pneumonia presenting with bilateral hilar and mediastinal lymphadenopathy.

    Science.gov (United States)

    Kahraman, Hasan; Tokur, Mahmut; Sayar, Hamide; Inci, Mehmet Fatih

    2013-06-10

    Cryptogenic organising pneumonia is not considered in the differential diagnosis of bilateral hilar and mediastinal lymphadenopathy. We submitted a patient presenting with bilateral hilar and mediastinal lymphadenopathy. We suspected diagnosis of sarcoidosis, but the patient was diagnosed as cryptogenic organising pneumonia with the histological result. This is the second case report of cryptogenic organising pneumonia presenting with bilateral hilar and mediastinal lymphadenopathy.

  3. Bilateral ovarian tumour in a young girl | Govindarajan | African ...

    African Journals Online (AJOL)

    Bilateral ovarian tumour in a girl presents the dilemma of conservative versus aggressive approach towards these tumours. When faced with suspicious tumour and complete replacement of the ovaries bilaterally, bilateral oophorectomy is a viable option, though the certain possibility of infertility and lifelong hormonal ...

  4. Signal loss in magnetic resonance imaging caused by intraoral anchored dental magnetic materials

    International Nuclear Information System (INIS)

    Blankenstein, F.H.; Naumann, M.; Truong, B.; Thomas, A.; Schroeder, R.J.

    2006-01-01

    Purpose: to measure the maximum extent of the signal loss areas in the center of the susceptibility artifacts generated by ferromagnetic dental magnet attachments using three different sequences in the 1.5 and 3.0 Tesla MRI. Materials and methods: five different pieces of standard dental magnet attachments with volumes of 6.5 to 31.4 mm 3 were used: a NdFeB magnet with an open magnetic field, a NdFeB magnet with a closed magnetic field, a SmCo magnet with an open magnetic field, a stainless steel keeper (AUM-20) and a PdCo piece. The attachments were placed between two cylindrical phantoms and examined in 1.5 and 3.0 Tesla MRI using gradient echo and T1- and T2-weighted spin echoes. We measured the maximum extent of the generated signal loss areas parallel and perpendicular to the direction of B O . Results: in gradient echoes the artifacts were substantially larger and symmetrically adjusted around the object. The areas with total signal loss were mushroom-like with a maximum extent of 7.4 to 9.7 cm parallel to the direction of B O and 6.7 to 7.4 cm perpendicular to B O . In spin echoes the signal loss areas were obviously smaller, but not centered. The maximum values ranged between 4.9 and 7.2 cm (parallel B O ) and 3.6 and 7.0 cm (perpendicular B O ). The different ferromagnetic attachments had no clinically relevant influence on the signal loss neither in 1.5 T nor 3.0 T MRI. Conclusions: ferromagnetic materials used in dentistry are not intraorally standardized. To ensure, that the area of interest is not affected by the described artifacts, the maximum extent of the signal loss area should be assumed: a radius of up to 7 cm in 1.5 and 3.0 T MRI by T1 and T2 sequences, and a radius of up to 10 cm in T2* sequences. To decide whether magnet attachments have to be removed before MR imaging, physicians should consider both the intact retention of the keepers and the safety distance between the ferromagnetic objects and the area of interest. (orig.)

  5. Evaluation of the composition of filters additional of equipment radiological intraoral by energy dispersive x-ray fluorescence (EDXRF)

    International Nuclear Information System (INIS)

    Franca, Alana Caroline; Torres, Catarina A.M.P.; Rocha, Ana S.S.; Deniak, Valeriy; Lara, Alessandro L.; Paschuk, Sergei A.; Fernandes, Angela; Westphalen, Fernando Henrique

    2013-01-01

    The need for high quality standards for radiographic images in order to make a diagnosis assertive, and being the additional filtration required in the intraoral X-ray equipment show the need of evaluating these filters. This study aims to examine the influence of the elemental composition of the filters of X-ray of dental intraoral equipment in the radiographic images quality. The filters analysis were performed by using the energy dispersive X-ray fluorescence method (EDXRF). Ten conventional filters were analysed. In this study, 33 radiographic exposures were performed using films: twenty radiographs in the incisor region and ten in the molar region, three exposures were also made in the same regions with same conditions without using filter. After radiographs development, optical density was measure and all radiographs were submitted to subjective evaluation by dental radiologists. Data obtained were correlated to effects evaluation of the elemental composition of all filters in the quality of the radiographic images. The elements found were: aluminum, cobalt, copper, sulfur, iron, manganese, titanium, zinc, and zirconium. The images obtained were identified in groups: Molars to 0.3 s; Incisors to 0.2 s; Incisors to 0.3 s, and for the group without filters. From the results obtained it was concluded that both unclear radiographs and ideal radiographs were produced by using filters of elementary common. Therefore, conventional filters evaluated were an acceptable option to produce quality images in dental radiology, despite differences in the composition of the alloys. (author)

  6. Long-term stability of intra-oral maxillary distraction in unilateral cleft lip and palate: a case report.

    Science.gov (United States)

    Nevzatoğlu, Sirin; Küçükkeleş, Nazan; Güzel, Zeki

    2013-11-01

    This case report presents short and long-term treatment results of a unilateral cleft lip and palate patient treated with a modified intra-oral tooth-bone borne distraction appliance. The chief complaints of a 16 year-old, unilateral cleft lip and palate patient were poor facial aesthetics, crowding and a fistula. Severe maxillary retrognathism was treated via distraction osteogenesis of the maxilla and performed using an intra-oral tooth-bone borne appliance. Treatment continued to completion with a multibracket system. At an eight-year review following the distraction procedure, the short and long-term results were determined cephalometrically. Following the distraction, A-point advanced 7 mm, 2 mm of which relapsed during fixed appliance treatment. At the end of the active treatment, the patient's skeletal and dental Class III relationship improved to Class I, which was preserved at the long-term review. The profile was markedly improved by the distraction osteogenesis. In cases of severe maxillary retrognathism as a result of a cleft lip and palate, maxillary distraction osteogenesis provides a viable alternative to orthognathic surgery.

  7. Evaluation of the composition of filters additional of equipment radiological intraoral by energy dispersive x-ray fluorescence (EDXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Franca, Alana Caroline; Torres, Catarina A.M.P.; Rocha, Ana S.S.; Deniak, Valeriy; Lara, Alessandro L.; Paschuk, Sergei A., E-mail: alanacarolinef@gmail.com, E-mail: sergei@utfpr.edu.br [Universidade Tecnologica Federal do Parana (CPGEI/UTFPR), Curitiba, PR (Brazil). Programa de Pos-Graduacao em Engenharia Eletrica e Informatica Industrial; Fernandes, Angela; Westphalen, Fernando Henrique, E-mail: angelafernandes@ufpr.br [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Setor de Ciencias da Saude

    2013-07-01

    The need for high quality standards for radiographic images in order to make a diagnosis assertive, and being the additional filtration required in the intraoral X-ray equipment show the need of evaluating these filters. This study aims to examine the influence of the elemental composition of the filters of X-ray of dental intraoral equipment in the radiographic images quality. The filters analysis were performed by using the energy dispersive X-ray fluorescence method (EDXRF). Ten conventional filters were analysed. In this study, 33 radiographic exposures were performed using films: twenty radiographs in the incisor region and ten in the molar region, three exposures were also made in the same regions with same conditions without using filter. After radiographs development, optical density was measure and all radiographs were submitted to subjective evaluation by dental radiologists. Data obtained were correlated to effects evaluation of the elemental composition of all filters in the quality of the radiographic images. The elements found were: aluminum, cobalt, copper, sulfur, iron, manganese, titanium, zinc, and zirconium. The images obtained were identified in groups: Molars to 0.3 s; Incisors to 0.2 s; Incisors to 0.3 s, and for the group without filters. From the results obtained it was concluded that both unclear radiographs and ideal radiographs were produced by using filters of elementary common. Therefore, conventional filters evaluated were an acceptable option to produce quality images in dental radiology, despite differences in the composition of the alloys. (author)

  8. Comparison of accuracies of an intraoral spectrophotometer and conventional visual method for shade matching using two shade guide systems.

    Science.gov (United States)

    Parameswaran, Vidhya; Anilkumar, S; Lylajam, S; Rajesh, C; Narayan, Vivek

    2016-01-01

    This in vitro study compared the shade matching abilities of an intraoral spectrophotometer and the conventional visual method using two shade guides. The results of previous investigations between color perceived by human observers and color assessed by instruments have been inconclusive. The objectives were to determine accuracies and interrater agreement of both methods and effectiveness of two shade guides with either method. In the visual method, 10 examiners with normal color vision matched target control shade tabs taken from the two shade guides (VITAPAN Classical™ and VITAPAN 3D Master™) with other full sets of the respective shade guides. Each tab was matched 3 times to determine repeatability of visual examiners. The spectrophotometric shade matching was performed by two independent examiners using an intraoral spectrophotometer (VITA Easyshade™) with five repetitions for each tab. Results revealed that visual method had greater accuracy than the spectrophotometer. The spectrophotometer; however, exhibited significantly better interrater agreement as compared to the visual method. While VITAPAN Classical shade guide was more accurate with the spectrophotometer, VITAPAN 3D Master shade guide proved better with visual method. This in vitro study clearly delineates the advantages and limitations of both methods. There were significant differences between the methods with the visual method producing more accurate results than the spectrophotometric method. The spectrophotometer showed far better interrater agreement scores irrespective of the shade guide used. Even though visual shade matching is subjective, it is not inferior and should not be underrated. Judicious combination of both techniques is imperative to attain a successful and esthetic outcome.

  9. Identification of the Procedural Accidents During Root Canal Preparation Using Digital Intraoral Radiography and Cone Beam Computed Tomography

    Directory of Open Access Journals (Sweden)

    Csinszka K.-Ivácson A.-

    2016-09-01

    Full Text Available Crown or root perforation, ledge formation, fractured instruments and perforation of the roots are the most important accidents which appear during endodontic therapy. Our objective was to evaluate the value of digital intraoral periapical radiographs compared to cone beam computed tomography images (CBCT used to diagnose some procedural accidents. Material and methods: Eleven extracted molars were used in this study. A total of 18 perforations and 13 ledges were created artifically and 10 instruments were fractured in the root canals. Digital intraoral periapical radiographs from two angles and CBCT scans were made with the teeth fixed in position. The images were evaluated and the number of detected accidents were stated in percentages. Statistical analysis was performed using the chi square-test. Results: On digital periapical radiographs the evaluators identified 12 (66.66% perforations, 10 (100 % separated instruments and 10 (76.9% created ledges. The CBCT scans made possible the recognition of 17 (94.66 % perforations, 9 (90 % separated instruments and 13 (100% ledges. The totally recognized accidental procedures showed significant differences between the two groups. (p<0.05 Conclusion: Digital periapical radiographs are the most common imaging modalities used during endodontic treatments. Though, the CBCT allows a better identification of the procedural accidents.

  10. Influence of intra-oral sensory impairment by anaesthesia on food comminution and mixing in dentate subjects.

    Science.gov (United States)

    Yoshida, E; Fueki, K; Wakabayashi, N

    2015-06-01

    Sensory input from sensory receptors regarding food morsels can affect jaw motor behaviours during mastication. The aim was to clarify the effects of intra-oral sensory input on the food-comminuting and food-mixing capacities of dentate subjects. Eleven dentate subjects without sensory dysfunction in their oro-facial region participated in this study. Local anaesthesia was achieved on the periodontal structures and on the oral mucosa of the subjects' preferred chewing side by injecting a lidocaine solution with adrenalin. At baseline (control) and after anaesthesia, data on the subjects' food-comminuting and food-mixing capacities were gathered. The food-comminuting capacity was quantified by measuring the degree of pulverisation of peanuts (objective hardness; 45.3 [Newton, N]) after a prescribed 20 chewing strokes. The food-mixing capacity was measured as the degree of immixture of a two-coloured paraffin wax cube after 10 chewing strokes. Wax cubes of three different hardness levels were used (soft, medium and hard: 20.3, 32.6 and 75.5 [N], respectively) and were chewed in random order. After anaesthesia, the subjects' food-comminuting capacity significantly decreased (P food-mixing capacity for each hardness level of the wax cubes (P food-mixing capacity (P deterioration of the mixing capacity increased as the hardness increased. In conclusion, intra-oral sensory input can affect both food-comminuting and food-mixing capacities. © 2015 John Wiley & Sons Ltd.

  11. Colgajo Sabattini-Abbe en H tumbada para reconstrucción de labio leporino bilateral secundario

    Directory of Open Access Journals (Sweden)

    Juan Márquez-Cañada

    Full Text Available La reconstrucción del labio leporino secundario tiene al colgajo Sabattini-Abbe como una de sus principales herramientas reconstructivas básicas, si bien se han propuesto diferentes modificaciones de la técnica original para lograr una minuciosa reconstrucción de las deformidades secundarias presentes en los pacientes con labio leporino. Presentamos una modificación del colgajo Sabattini-Abbe, el colgajo en H tumbada. Este colgajo modificado incluye un segmento vertical y dos horizontales para restaurar con un solo colgajo, y adhiriéndonos al principio de la Cirugía Plástica de reconstruir lo similar con lo similar, tanto piel como bermellón de las áreas central y laterales del labio superior, las cuales se hallan comúnmente afectadas en los pacientes con labio leporino bilateral secundario.

  12. Diffusion MR Imaging of Postoperative Bilateral Acute Ischemic Optic Neuropathy

    International Nuclear Information System (INIS)

    Park, Ju Young; Lee, In Ho; Song, Chang June; Hwang, Hee Youn

    2012-01-01

    A 57-year-old woman experienced bilateral acute ischemic optic neuropathy after spine surgery. Routine MR imaging sequence, T2-weighted image, showed subtle high signal intensity on bilateral optic nerves. A contrast-enhanced T1 weighted image showed enhancement along the bilateral optic nerve sheath. Moreover, diffusion-weighted image (DWI) and an apparent diffusion coefficient map showed markedly restricted diffusion on bilateral optic nerves. Although MR findings of T2-weighted and contrast enhanced T1-weighted images may be nonspecific, the DWI finding of cytotoxic edema of bilateral optic nerves will be helpful for the diagnosis of acute ischemic optic neuropathy after spine surgery.

  13. Diffusion MR Imaging of Postoperative Bilateral Acute Ischemic Optic Neuropathy

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ju Young; Lee, In Ho; Song, Chang June [Chungnam National University Hospital, Daejeon (Korea, Republic of); Hwang, Hee Youn [Eulji University Hospital, Daejeon(Korea, Republic of)

    2012-03-15

    A 57-year-old woman experienced bilateral acute ischemic optic neuropathy after spine surgery. Routine MR imaging sequence, T2-weighted image, showed subtle high signal intensity on bilateral optic nerves. A contrast-enhanced T1 weighted image showed enhancement along the bilateral optic nerve sheath. Moreover, diffusion-weighted image (DWI) and an apparent diffusion coefficient map showed markedly restricted diffusion on bilateral optic nerves. Although MR findings of T2-weighted and contrast enhanced T1-weighted images may be nonspecific, the DWI finding of cytotoxic edema of bilateral optic nerves will be helpful for the diagnosis of acute ischemic optic neuropathy after spine surgery.

  14. Giochiamo con i robot

    Directory of Open Access Journals (Sweden)

    Andrea Bonarini

    2009-01-01

    Full Text Available "Giochiamo con i robot" e' un laboratorio interattivo per grandi e piccini realizzato per l'edizione 2007 del Festival della Scienza di Genova. Lungo un percorso che va dalla telerobotica alla robotica evolutiva, il laboratorio sviluppa il tema di dare intelligenza ai robot. Questo percorso, le cui tappe sono le varie installazioni, si conclude nella "bottega" dove e' possibile costruire e programmare i propri robot o smontare e modificare quelli esposti durante il percorso didattico. I visitatori sono coinvolti in attivita' ludiche grazie alle quali possonoentrare in contatto con alcune delle idee potenti della robotica,

  15. disegnare con ... Alberto Pratelli

    Directory of Open Access Journals (Sweden)

    Roberto Mingucci

    2017-12-01

    Full Text Available Con questa breve intervista ad Alberto Pratelli, (non a caso scelto per aprire questa nuova rubrica intendia-mo inaugurare un dialogo con personalità significati-ve del Disegno di Architettura, che consenta riflessioni dedicate alle sue varie dimensioni, oggi più che mai da approfondire. La suggestione a farlo, viene da un’idea di Pablo Rodri-guez Navarro ed abbiamo quindi pensato di avviarla proprio in questo numero, che Pablo ha accettato di curare su un tema a lui particolarmente caro.

  16. Cataratas senil bilateral psicológico pre y posoperatorio Bilateral senile cataract: a pre- and postoperavitve psychological study

    Directory of Open Access Journals (Sweden)

    Armando Rodríguez Romero

    2003-12-01

    Full Text Available Se realizó un estudio psicológico comparativo en 50 pacientes con catarata senil bilateral antes y después de la operación, en el período comprendido de enero a diciembre de1999 según las variables de edad, escolaridad y estado civil. Predominó el grupo etáreo de 70 a 79 años, nivel escolar primario y estado civil casado. Los síntomas psicopatológicos y la distribución según trastornos psiquiátricos disminuyeron después de restablecida su visión una vez operados de cataratas, en los de ansiedad y tristeza de 42 a7 pacientes respectivamente.A psychological comparative study was conducted among 50 patients with senile bilareral cataract before and after the operation from January to December, 1999, according to the following variables: age, educational level and marital status. The age group 70-79, the elementary educational level and the married patients predominated. The psychopathological symptoms and the distribution according to psychiatric disorders decreased among those with anxiety and sadness from 42 to 7 patients, respectively, once they were operated on of cataract and their vision was reestablished.

  17. Bilateral complex regional pain syndrome following spinal cord injury and bilateral calcaneus fracture

    Directory of Open Access Journals (Sweden)

    Ahmet Boyacı

    2013-09-01

    Full Text Available Complex regional pain syndrome (CRPS is a disease affectingone or more extremities, characterized by spontaneouspain, allodynia, hyperpathia and hyperalgesia.CRPS is separated into Type 1 and Type 2. CRPS whichdevelops after a nociceptive event is labeled as Type 1and when it develops following peripheral nerve damage,Type 2. Although the pathogenesis is not fully understood,peripheral and central sensitivity are held responsible.Bilateral lower extremity involvement is extremely rare.However, it should be borne in mind that it can develop intraumatic injuries which occur in more than one area anddiagnosis and commencement of a rehabilitation programshould be made in the early period. The case is presentedhere of bilateral Type 1 CRPS developing after incompletespinal cord injury and bilateral calcaneus fracture. JClin Exp Invest 2013; 4 (3: 360-363Key words: complex regional pain syndrome, calcaneusfracture, spinal cord injury

  18. Conversando con Oriol Bohigas

    OpenAIRE

    Redondo Domínguez, Ernesto; Moya Sala, Joaquim

    2015-01-01

    [EN] Interview with Oriol Bohigas [ES] Entrevista con Oriol Bohigas Redondo Domínguez, E.; Moya Sala, J. (2015). Conversando con… Oriol Bohigas. EGA. Revista de Expresión Gráfica Arquitectónica. 20(26):22-35. doi:10.4995/ega.2015.4061 22 35 20 26

  19. DR Con o:

    African Journals Online (AJOL)

    which could fall under the Ugandan influence. The con-. flict in the ..... The Congolese people and international community within SADC, the AU ..... ments and make peace among themselves. However, one ... friends overnight.There is a great ...

  20. Bilateral Complex Regional Pain Syndrome after Fracture of Bilateral Tibia and Fibula

    Directory of Open Access Journals (Sweden)

    Senem Şaş

    2017-04-01

    Full Text Available Complex regional syndrome type 1 (CRPS-1 is a painful clinical condition. It occurs after a painful event and characterized by allodynia, hyperalgesia, edema, abnormalities in skin blood flow and abnormal sudomotor activity. When CRPS-1 is associated with nerve injury, it is defined as CRPS-2. Central and peripheral theory are responsible in etiopathogenesis of CRPS-1. Generally it occurs in the injured limb. But, it may ocur in the opposite extremities. In this article, we present a case developing bilateral CRPS-1 after bilateral tibia and fibula fracture by reviewing current literatüre.

  1. Ceratite bilateral por Acanthamoeba: relato de caso Bilateral Acanthamoeba keratitis: case report

    Directory of Open Access Journals (Sweden)

    Wilson Nahmatallah Obeid

    2003-12-01

    Full Text Available A ceratite por Acanthamoeba é uma infecção ocular grave que, apesar dos recentes progressos no diagnóstico e tratamento, ainda provoca prolongada morbidade e perda da acuidade visual. Relatamos um caso de ceratite bilateral por Acanthamoeba em usuário de lentes de contato, que é o primeiro caso descrito na literatura brasileira.Acanthamoeba keratitis is a severe ocular infection which even with recent progress in diagnosis and treatment still causes long morbidity and loss of visual acuity. We describe a case of bilateral Acanthamoeba keratitis in a user of contact lenses, which is the first case discussed in Brazilian literature.

  2. Linear accelerator-based stereotactic radiosurgery for bilateral vestibular schwannomas in patients with neurofibromatosis type 2

    NARCIS (Netherlands)

    Meijer, Otto W. M.; Vandertop, W. Peter; Lagerwaard, Frank J.; Slotman, Ben J.

    2008-01-01

    OBJECTIVE: Patients with neurofibromatosis Type 2 (NF2) patients typically have bilateral vestibular schwannomas (VS) and are at risk for developing bilateral deafness, bilateral trigeminal, and bilateral facial nerve function loss. Previous reports suggested that treatment outcomes in these

  3. Bilateral inferior petrosal sinus sampling using vasopressin

    Directory of Open Access Journals (Sweden)

    Narendra Kotwal

    2016-01-01

    Full Text Available Context: Anatomical localization of pituitary adenoma can be challenging in adrenocorticotropic hormone (ACTH-dependent Cushing's syndrome, and bilateral inferior petrosal sinus sampling (BIPSS is considered gold standard in this regard. Stimulation using corticotrophin-releasing hormone (CRH improves the sensitivity of BIPSS, however, same is not easily available in India. Therefore, we undertook this study of BIPPS using vasopressin as agent for stimulation owing to its ability to stimulate V3 receptors present on corticotrophs. Aims: To study the tumor localization and lateralization in difficult to localize cases of ACTH-dependent Cushing's syndrome by bilateral inferior petrosal sinus sampling using vasopressin for corticotroph stimulation. Settings and Design: Prospective observational study. Subjects and Methods: Six patients (5 females meeting inclusion criteria underwent BIPSS using vasopressin for stimulation. Results: All six patients had nonsuppressible overnight and low dose dexamethasone suppression test with elevated plasma ACTH levels suggestive of ACTH-dependent Cushing's syndrome. High dose dexamethasone suppression test showed suppressible cortisol in two cases, and microadenoma was seen in two patients on magnetic resonance imaging pituitary. Contrast enhanced computed tomography of the abdomen showed left adrenal hyperplasia in one case and anterior mediastinal mass with bilateral adrenal hyperplasia another. Using BIPSS four patients were classified as having Cushing's disease that was confirmed histopathologically following surgery. Of the remaining two, one had primary pigmented nodular adrenocortical disease, and another had thymic carcinoid with ectopic ACTH production as the cause of Cushing's syndrome. No serious adverse events were noted. Conclusions: Vasopressin may be used instead of CRH and desmopressin for stimulation in BIPSS.

  4. Idiopathic Bilateral External Jugular Vein Thrombosis.

    Science.gov (United States)

    Hindi, Zakaria; Fadhel, Ehab

    2015-08-20

    Vein thrombosis is mainly determined by 3 factors, which constitute a triad called Virchow's triad: hypercoagulability, stasis, and endothelial injury. Venous thrombosis commonly occurs in the lower extremities since most of the blood resides there and flows against gravity. The veins of the lower extremities are dependent on intact valves and fully functional leg muscles. However, in case of valvular incompetency or muscular weakness, thrombosis and blood stasis will occur as a result. In contrast, the veins of the neck, specially the jugulars, have distensible walls which allow flexibility during respiration. In addition, the blood directly flows downward towards the heart. Nevertheless, many case reports mentioned the thrombosis of internal jugular veins and external jugular veins with identified risk factors. Jugular vein thrombosis has previously been associated in the literature with a variety of medical conditions, including malignancy. This report is of a case of idiopathic bilateral external jugular vein thrombosis in a 21 year-old male construction worker of Southeast Asian origin with no previous medical history who presented with bilateral facial puffiness of gradual onset over 1 month. Doppler ultrasound and computed tomography were used in the diagnosis. Further work-up showed no evidence of infection or neoplasia. The patient was eventually discharged on warfarin. The patient was assessed after 6 months and his symptoms had resolved completely. Bilateral idiopathic external jugular veins thrombosis is extremely rare and can be an indicator of early malignancy or hidden infection. While previous reports in the literature have associated jugular vein thrombosis with malignancy, the present case shows that external jugular vein thrombosis can also be found in persons without malignancy.

  5. Parasternal lymphoscintigraphy using the bilateral collimator

    International Nuclear Information System (INIS)

    Ohtake, Eiji; Iio, Masahiro; Toyama, Hinako; Kawaguchi, Shinichiro; Murata, Hajime

    1981-01-01

    A new method for measuring the depth of the parasternal lymph node was studied. The bilateral collimator used in this study consisted of two arrays of parallel holes which were slanted at +-30 degrees, respectively, to the vertical line. When the collimator was set to image the object in both sides of the field, the object and the dual images formed a regular triangle. The distance (D) from the image (crystal) plane to the object can be expressed by the equation: D = 1/2.L.cot30 0 = 0.866.L where L is the interval between the dual images calibrated to the real length. The distance from the collimator surface to the object is obtained by subtracting the effective thickness (T) between the image plane and the collimator surface from D. T was experimentally measured by the above equation, placing point sources on the collimator surface. The principle was applied to measure the depth of the parasternal lymph node. The parasternal lymphoscintigram was obtained four hours after bilateral subcostal injection of sup(99m)Tc-sulfur colloid and the image was taken by a Searle Pho/Gamma LFOV camera equipped with the bilateral collimator. When the scintigraphic image was made, radioactive markers were placed at the body surface to measure the distance from the collimator surface to the body surface Nineteen patients were examined. As a result, the lymph nodes were found to be located in the depths ranging widely from 0.4 to 6.5 cm from the anterior surface of the chest wall. These lymph nodes were thought to contain the deeply seated mediastinal nodes, and the superficial nodes located directly beneath the skin. Model studies were also performed to estimate the accuracy of this method and satisfactory results were obtained. (author)

  6. Bilateral first rib fractures: A case report

    Directory of Open Access Journals (Sweden)

    Dilip Amonkar

    2014-01-01

    Full Text Available From the time first rib fractures were first described in 1869, they have been a source of anxiety to attendant trauma surgeons working in the accident and emergency department of major hospitals. First rib fractures are associated with major thoracic trauma and may involve injury to subclavian vessels, brachial plexus, and mediastinal structures. But these complications are more often seen following unilateral first rib fractures. In contrast, bilateral first rib fractures may follow insignificant trauma, suggesting a different mechanism involved. Serious vascular injuries and brachial plexus injuries are rare and angiograms for evaluation of these patients aren′t routinely warranted. The case that we report illustrates this very point.

  7. Treatment of Bilateral Buccal Nonocclusion and Distalization

    Directory of Open Access Journals (Sweden)

    Nagarajan Sadhasivam

    2014-01-01

    Full Text Available Orthodontic treatment aims to improve esthetics, function and structural balance. In some rare circumstances, the clinician may not be able to achieve the ideal treatment goals because of complex multiple orthodontic problems, which may include significant mutilation of the dentition. Brodie bite, a complete buccal posterior crossbite is a problem, which confronts clinicians with often complex variable etiology. The following case report demonstrates treatment of bilateral buccal nonocclusion that is mainly due to a maxillary dental arch issue rather than mandibular retrognathism.

  8. Primary Amenorrhea with Bilateral Endometriotic Cysts

    International Nuclear Information System (INIS)

    Jabeen, S.; Raees, M.

    2015-01-01

    Primary amenorrhea is a common problem. Diagnosis is usually by going through systematic approach of history, examination and investigations. This case had bilateral large endometriotic cysts in the adnexal region. Uterus was normal sized with well-formed endometrium. She underwent laparotomy followed by drainage of endometriotic cysts, stripping and reconstruction of ovaries was performed. Patient was given a trial of combined oral contraceptive pills for two consecutive cycles to observe withdrawal bleeding, but it failed. Till now we are unable to find out such case in literature. Exact case of primary amenorrhea could not be found. (author)

  9. Bilateral pneumothoraces secondary to acupuncture therapy.

    Science.gov (United States)

    Nguyen, Theresa M; Roy, Neil K; Zlupko, George R

    2011-09-01

    Acupuncture is becoming increasingly popular in the United States for a wide variety of uses, ranging from the treatment of chronic back pain to aiding in addiction therapy. As this form of complementary and alternative medicine becomes more prevalent in certain areas of the country, it is of paramount importance that the emergency physician be familiar with its methods and potential complications. In general, acupuncture is perceived as fairly safe. However, it is not without risks or side effects. In this case report, we discuss the history, methods, and common complications of acupuncture in the context of a patient who presented to the Emergency Department (ED) with bilateral pneumothoraces secondary to acupuncture therapy.

  10. True bilateral nasopharyngeal angiofibroma: report and review.

    Science.gov (United States)

    Mishra, Anupam; Mishra, Subhash Chandra

    2016-10-01

    This report describes the third case of a true bilateral Juvenile nasopharyngeal angiofibroma (JNA), i.e. two separate JNA arising from both sides simultaneously. The associated multiple recurrences in such a case have not yet been reported. A 21-year-man underwent transpalatal excision and recurred twice. The last 'neo-occurrence' encountered after 2 years was at a different site and was subsequently managed by post-embolization endoscopic resection. A complete report of its clinico-radiological features and management outcome is discussed.

  11. Bilateral Cochlear Implants: Maximizing Expected Outcomes.

    Science.gov (United States)

    Wallis, Kate E; Blum, Nathan J; Waryasz, Stephanie A; Augustyn, Marilyn

    Sonia is a 4 years 1 month-year-old girl with Waardenburg syndrome and bilateral sensorineural hearing loss who had bilateral cochlear implants at 2 years 7 months years of age. She is referred to Developmental-Behavioral Pediatrics by her speech/language pathologist because of concerns that her language skills are not progressing as expected after the cochlear implant. At the time of the implant, she communicated using approximately 20 signs and 1 spoken word (mama). At the time of the evaluation (18 months after the implant) she had approximately 70 spoken words (English and Spanish) and innumerable signs that she used to communicate. She could follow 1-step directions in English but had more difficulty after 2-step directions.Sonia was born in Puerto Rico at 40 weeks gestation after an uncomplicated pregnancy. She failed her newborn hearing test and was given hearing aids that did not seem to help.At age 2 years, Sonia, her mother, and younger sister moved to the United States where she was diagnosed with bilateral severe-to-profound hearing loss. Genetic testing led to a diagnosis of Waardenburg syndrome (group of genetic conditions that can cause hearing loss and changes in coloring [pigmentation] of the hair, skin, and eyes). She received bilateral cochlear implants 6 months later.Sonia's mother is primarily Spanish-speaking and mostly communicates with her in Spanish or with gestures but has recently begun to learn American Sign Language (ASL). In a preschool program at a specialized school for the deaf, Sonia is learning both English and ASL. Sonia seems to prefer to use ASL to communicate.Sonia receives speech and language therapy (SLT) 3 times per week (90 minutes total) individually in school and once per week within a group. She is also receiving outpatient SLT once per week. Therapy sessions are completed in English, with the aid of an ASL interpreter. Sonia's language scores remain low, with her receptive skills in the first percentile, and her

  12. Bilateral condylar resorption in down syndrome.

    Science.gov (United States)

    Grippaudo, Cristina; Grippaudo, Francesca Romana; Marianetti, Tito Matteo; Cacucci, Laura; Deli, Roberto; Pelo, Sandro

    2014-11-01

    Asymptomatic idiopathic condylar resorption is a rare disease of difficult diagnosis and treatment. We review the literature about this rare condition and report a case of a patient, affected by Down syndrome, who underwent a complete untreated bilateral condylar resorption in adolescence and then developed pain on chewing only 20 years later. Despite a precise orthodontic and surgical therapeutic plan, treatment had to be discontinued because of patient lack of compliance. This case is the first of its kind to be reported and emphasizes the need for special attention in patients with disability.

  13. Bilateral contact problem with adhesion and damage

    Directory of Open Access Journals (Sweden)

    Adel Aissaoui

    2014-05-01

    Full Text Available We study a mathematical problem describing the frictionless adhesive contact between a viscoelastic material with damage and a foundation. The adhesion process is modeled by a bonding field on the contact surface. The contact is bilateral and the tangential shear due to the bonding field is included. We establish a variational formulation for the problem and prove the existence and uniqueness of the solution. The existence of a unique weak solution for the problem is established using arguments of nonlinear evolution equations with monotone operators, a classical existence and uniqueness result for parabolic inequalities, and Banach's fixed point theorem.

  14. fertilizada con diferentes abonos

    Directory of Open Access Journals (Sweden)

    Jorge Alberto Elizondo-Salazar

    2007-01-01

    Full Text Available Producción y calidad de la biomasa de morera (Morus alba fertilizada con diferentes abonos. Se llevó a cabo un experimento en la Estación Experimental “Alfredo Volio Mata” de la Universidad de Costa Rica con el fi n de evaluar la aplicación de 150 kg de N/ha/año proveniente de dos abonos orgánicos: lombriabono y compostaje; y de un fertilizante químico, sobre la producción y calidad de la biomasa de morera. El periodo experimental comprendió un ciclo de 12 meses, iniciando en julio del 2003 y fi nalizando en julio del 2004. Se utilizó una plantación de morera de 12 años de establecida con una densidad de siembra de 27.777 plantas/ ha. Se empleó un diseño de bloques completos al azar con cuatro tratamientos: dos abonos orgánicos, nitrato de amonio (33,5% N y un control. Las plantas se podaron a 0,6 m sobre el nivel del suelo al inicio del ensayo. Durante el periodo experimental, las plantas fueron podadas consecutivamente cada 90 días. Las hojas y los tallos fueron separados y analizados para determinar el contenido de materia seca y proteína cruda. La producción de materia seca fue 23% superior y el contenido de proteína cruda fue signifi cativamente mayor con el nitrógeno químico, mientras que el contenido de materia seca fue menor. No se encontraron diferencias signifi cativas entre el tratamiento control y los tratamientos orgánicos.

  15. RECONSTRUCCIÓN DEL MAXILAR SUPERIOR POSTERIOR ATRÓFICO CON CÉLULAS MADRE MESENQUIMALES

    OpenAIRE

    Martí Pagès, Carles

    2009-01-01

    Se realiza un estudio clínico en el lnstituto de Cirugía Maxilofacial e Implantologia tras pasar el comité ético del Centro Medica Teknon. Es un estudio randomizado, controlado utilizando un diseño tipo "split mouth" en el cual cada paciente sirve de propio control. SE realiza a 5 pacientes, con atrofia posterior del maxilar superior sin posibilidad de instalar implantes fueron tratados con reconstrucción mediante la técnica de elevación sinusal bilateral, rellenando un sena con Bio-as...

  16. Marginal and internal fit of CAD-CAM-fabricated composite resin and ceramic crowns scanned by 2 intraoral cameras.

    Science.gov (United States)

    de Paula Silveira, Alessandra C; Chaves, Sacha B; Hilgert, Leandro A; Ribeiro, Ana Paula D

    2017-03-01

    The precision of fit of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) complete crowns is affected by digital impression and restorative material. The purpose of this in vitro study was to evaluate by microcomputed tomography (μCT) the marginal and internal adaptation of composite resin and ceramic complete crowns fabricated with 2 different intraoral cameras and 2 restorative materials. Ten extracted human third molars received crown preparations. For each prepared molar, 2 digital impressions were made with different intraoral cameras of the CEREC system, Bluecam and Omnicam. Four groups were formed: LB (Lava Ultimate+Bluecam), EB (Emax+Bluecam), LO (Lava Ultimate+Omnicam), and EO (Emax+Omnicam). Before measuring the precision of fit, all crowns were stabilized with a silicone material. Each unit (crown + prepared tooth) was imaged with μCT, and marginal and internal discrepancies were analyzed. For the 2D analysis, 120 measurements were made of each crown for marginal adaptation, 20 for marginal discrepancy (MD), and 20 for absolute marginal discrepancy (AMD); and for internal adaptation, 40 for axial space (AS) and 40 for occlusal space (OS). After reconstructing the 3D images, the average internal space (AIS) was calculated by dividing the total volume of the internal space by the contact surface. Data were analyzed with 2-way ANOVA and quantile regression. Regarding marginal adaptation, no significant differences were observed among groups. For internal adaptation measured in the 2D evaluation, a significant difference was observed between LO and EO for the AS variable (Mann-Whitney test; POmnicam, and composite resin crowns showed less discrepancy than did ceramic crowns. The marginal adaptations assessed in all groups showed values within the clinically accepted range. Moreover, the composite resin blocks associated with the Bluecam intraoral camera demonstrated the best results for AIS compared with those of the other groups

  17. The prophylactic effect of neck irradiation combined with intra-oral electron beam irradiation for early tongue cancer

    International Nuclear Information System (INIS)

    Kawamori, Jiro; Kamata, Rikisaburo; Sanuki, Eiichi

    1993-01-01

    Between 1967 and 1988, 102 patients with Stage T1-2N0 squamous cell carcinoma of the tongue were treated with uneven fractional irradiation therapy (intra-oral electron beam irradiation with and without prophylactic ipsilateral upper neck irradiation at the Dept. of Radiology, Nihon University School of Medicine. Of 102 primary lesions, 89 cases were controlled with this therapy. In this study, these 89 cases were investigated in order to analyze the prophylactic effect of upper neck irradiation. Of the 89 patients, 42 received only intra-oral electron beam irradiation, while the remaining 47 received a combination of intra-oral electron beam irradiation and prophylactic irradiation to the ipsilateral upper neck. Twenty three of the 89 (25.8%) developed metastasis to the neck after the radiotherapy. A breakdown of these 23 cases reveals that 3/21 (14.3%) received 40-50 Gy to the neck, 9/26 (34.6%) received 20-40 Gy to the neck, and 11/42 (26.2%) received no irradiation to the neck (p<0.05 between first and second groups, and between first and third groups). The neck metastasis was classified into one of three categories based on the region in which it first appeared (ipsilateral upper neck, ipsilateral lower neck or contralateral neck). The first metastasis was seen in the ipsilateral upper neck, in the ipsilateral lower neck and in the contralateral neck in 17, 4 and 2 patients, respectively. In 1/19 who had received 40-50 Gy, in 5/21 who had received 20-40 Gy and in 11/42 who had not received neck irradiation the first metastasis appeared in the ipsilateral upper neck. The five year survival rate was 94%, 75% and 85% in the patients receiving 40-50 Gy, 20-40 Gy and no neck irradiation, respectively. These results suggest that prophylactic irradiation of 40-50 Gy to the ipsilateral upper neck might decrease the incidence of neck metastasis and slightly prolong survival time. (author)

  18. Three-Dimensional Accuracy of Digital Static Interocclusal Registration by Three Intraoral Scanner Systems.

    Science.gov (United States)

    Wong, Kuan Yee; Esguerra, Roxanna Jean; Chia, Vanessa Ai Ping; Tan, Ying Han; Tan, Keson Beng Choon

    2018-02-01

    Prior studies have defined the accuracy of intraoral scanner (IOS) systems but the accuracy of the digital static interocclusal registration function of these systems has not been reported. This study compared the three-dimensional (3D) accuracy of the digital static interocclusal registration of 3 IOS systems using the buccal bite scan function. Three IOS systems compared were 3M TM True Definition Scanner (TDS), TRIOS Color (TRC), and CEREC AC with CEREC Omnicam (CER). Using each scanner, 7 scans (n = 7) of the mounted and articulated SLA master models were obtained. The measurement targets (SiN reference spheres and implant abutment analogs) were in the opposing models at the right (R), central (C), and left (L) regions; abutments #26 and #36, respectively. A coordinate measuring machine with metrology software compared the physical and virtual targets to derive the global 3D linear distortion between the centroids of the respective target reference spheres and abutment analogs (dR R , dR C , dR L , and dR M ) and 2D distances between the pierce points of the abutment analogs (dX M , dY M , dZ M ), with 3 measurement repetitions for each scan. Mean 3D distortion ranged from -471.9 to 31.7 μm for dR R , -579.0 to -87.0 μm for dR C , -381.5 to 69.4 μm for dR L , and -184.9 to -23.1 μm for dR M . Mean 2D distortion ranged from -225.9 to 0.8 μm for dX M , -130.6 to -126.1 μm for dY M , and -34.3 to 26.3 μm for dZ M . Significant differences were found for interarch distortions across the three systems. For dR R and dR L , all three test groups were significantly different, whereas for dR C , the TDS was significantly different from the TRC and CER. For 2D distortion, significant differences were found for dX M only. Interarch and global interocclusal distortions for the three IOS systems were significantly different. TRC performed overall the best and TDS was the worst. The interarch (dR R , dR C , dR L ) and interocclusal (dX M ) distortions observed will

  19. Bilateral acute retinal necrosis after herpetic meningitis

    Directory of Open Access Journals (Sweden)

    Katsura T

    2012-04-01

    Full Text Available Keisho Hirota1,2, Masayuki Akimoto1,3, Toshiaki Katsura21Department of Ophthalmology, Kyoto Medical Center, National Hospital Organization, 2Internal Medicine, Kyoto Medical Center, 3Clinical Research Center, Kyoto Medical Center, Kyoto, JapanPurpose: The report of a case of bilateral acute retinal necrosis after herpetic meningitis.Case report: A 47-year-old man was admitted with the chief complaint of persistent high fever and transient loss of consciousness. Although his general condition improved after intravenous acyclovir administration, the patient presented with visual loss in both eyes 4 days after admission. Visual acuity in his right eye was 20/200 and his left eye had light perception alone. Both eyes showed panretinal arteritis diagnosed as acute retinal necrosis. Panretinal photocoagulation was performed for both eyes. Progression of retinal detachment was prevented in both eyes; however, visual acuity of the left eye was totally lost because of neovascular glaucoma. Visual acuity of the right eye recovered to 20/20.Conclusion: Although cases of bilateral acute retinal necrosis have been reported after herpetic encephalitis, this condition is rare after herpetic meningitis. Prophylactic acyclovir therapy and early panretinal photocoagulation may prevent retinal detachment and improve the prognosis. Neurologists and ophthalmologists should be aware that not only herpetic encephalitis but also herpetic meningitis can lead to acute retinal necrosis within a very short interval.Keywords: acute retinal necrosis, herpetic meningitis, herpes simplex, varicella zoster virus

  20. Bilateral Electrical Cataract: A Case Report

    Directory of Open Access Journals (Sweden)

    Selçuk Sızmaz

    2011-06-01

    Full Text Available To present a rare complication, such as bilateral cataracts, in a man who sustained a high-voltage electrical injury. A 35- year-old man was admitted with a complaint of decrease in visual acuity. He had a history of a contact with a power line carrying 30.000 volts of electricity while working at a construction site. Examination at a burn center revealed second-degree facial, neck and left foot burns. One month later, the patient underwent amputation of fourth and fifth toes of his left foot. During the next 6 months, he noted decreasing vision in both eyes. Ocular examination 1 year after the accident revealed that the patient’s visual acuity had deteriorated to 1/10 in both eyes. The cornea on the left eye showed superficial punctate opacities. The lenses in both eyes had anterior subcapsular cortical lens opacities and posterior subcapsular opacities. Uncomplicated bilateral phacoemulsification surgery with intraocular lens implantation was performed and the patient’s visual acuity returned to 10/10 in both eyes. We noted that the fundus remained normal in both eyes. Electrical cataracts are still a serious potential complication that may occur after electrical injury. Awareness of this by burn team members is important for providing optimal treatment to those who have suffered an electrical injury. (Turk J Ophthalmol 2011; 41: 197-9

  1. Bilateral tension pneumothorax following equipment improvisation.

    Science.gov (United States)

    Zambricki, Christine; Schmidt, Carol; Vos, Karen

    2014-02-01

    This case report describes an unexpected event that took place as a result of using improvised equipment. The patient, a 16-year-old female undergoing complex oral surgery, suffered bilateral pneumothorax following the improper use of an airway support device. During the immediate postoperative period with the patient still intubated, oxygen tubing was attached to a right angle elbow connector with the port closed and 10 L/minute oxygen flow was administered to the patient in a manner that did not allow the patient to exhale. Within seconds, pneumothorax was apparent as the patient's vital signs deteriorated, visible swelling was noted in the shoulders and neck, and there was an absence of breath sounds on auscultation. This case study has application beyond the immediate discussion of bilateral pneumothorax, serving as a caution about the unintended consequences of equipment improvisation. In addition to highlighting the hazards of providing patient care with a non-standard device, this study also provides a powerful example of the human factors that can contribute to medical errors in the healthcare setting.

  2. Bilateral parotid gland tuberculosis: A rare occurrence

    Directory of Open Access Journals (Sweden)

    Rajendra Takhar

    2015-07-01

    Full Text Available Parotid gland tuberculosis is an extremely rare form of extrapulmonary tuberculosis, even in countries where tuberculosis is endemic like India; however, it should be included as one of the differentials of discrete parotid swelling as it generally presents as a slow-growing mass indistinguishable from a malignancy and even imaging too, can’t differentiate these clearly. The majority of the previously reported cases were mostly unilateral and diagnosed by histopathological examination of post parotidectomy specimens. Here we are describing a case of tuberculosis of both parotid glands in a 25 year-old male who was referred to us with bilateral parotid region swelling of two month duration. Tubercular parotiditis was confirmed by demonstration of epithelioid granuloma and caseous necrosis compatible with TB on fine needle aspiration cytology (FNAC. He was treated with four drug anti-TB regimen (2HERZ + 4HR leading to full recovery and complete disappearance of swelling and symptoms with no recurrence till one year of follow up. Apart from rarity due to bilateral involvement, this case report highlights the clinical presentation, ultrasonography and other imaging findings, and significance of FNAC in diagnosis of this uncommon entity reinforcing the fact that the diagnosis of parotid gland tuberculosis requires a high degree of clinical suspicion.

  3. Bilateral Pneumothoraces Following Central Venous Cannulation

    Directory of Open Access Journals (Sweden)

    F. Pazos

    2009-01-01

    Full Text Available We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right pleural space before cannulation of the right subclavian vein. After the procedure, the patient slowly became hemodynamically instable with respiratory distress. A chest radiograph revealed a complete left-side pneumothorax and a mild right-side pneumothorax. The right-side pneumothorax became under tension after left chest tube insertion. The symptoms finally resolved after insertion of a right chest tube. After a diagnostic work-up, we suspect a congenital “Buffalo chests” explaining bilateral pneumothoraces and a secondary tension pneumothorax.

  4. Fast bilateral filtering of CT-images

    Energy Technology Data Exchange (ETDEWEB)

    Steckmann, Sven; Baer, Matthias; Kachelriess, Marc [Erlangen-Nuernberg Univ., Erlangen (Germany). Inst. of Medical Physics (IMP)

    2011-07-01

    The Bilateral filter is able to get a lower noise level while retaining the edges in images. The downside of a bilateral filter is the high order of the problem itself. While having a Volume size of N with a dimension of d and a filter window of r the problem is of size N{sup d} . r{sup d}. In the literature there are some proposals for speeding up by reducing this order by approximating a component of the filter. This leads to inaccurate results which often implies non acceptable artifacts for medical imaging. A better way for medical imaging is to speed up the filter itself while leaving the basic structure intact. This is the way our implementation uses. We solve the problem of calculating the function of e{sup -x} in an efficient way on modern architectures, and the problem of vectorizing the filtering process. As result we implemented a filter which is 2.5 times faster than the highly optimized basic approach. By comparing the basic analytical approach with the final algorithm, the differences in quality of the computing process is negligible to the human eye. We are able to process a volume with 512{sup 3} voxels with a filter of 25 x 25 x 1 in 21 s on a modern Intel Xeon platform with two X5590 processors running at 3.33 GHz. (orig.)

  5. Bilateral cervical spondylolysis of C7.

    Science.gov (United States)

    Paik, Nam Chull

    2010-11-01

    Cervical spondylolysis, which is defined as a cleft between the superior and inferior articular facets of the articular pillar, is a rare condition. The sixth cervical vertebra (C6) is the level most commonly affected. Cases involving C2, C3, C4, or C5 have also been reported. However, to date, no case of C7 spondylolysis has been reported. To present a rare case of bilateral spondylolysis of the seventh cervical vertebra (C7) in a 58-year-old man. A case report. A 58-year-old man visited our hospital with chronic posterior neck pain radiating to the left upper extremity. Magnetic resonance imaging (MRI) study revealed left foraminal disc herniations at C5-C6 and C6-C7. Cervical spondylolysis involving C7 was discovered incidentally during computed tomography (CT)-guided transforaminal steroid injection. Plain radiographs, CT images, and MRIs were reviewed thoroughly once again. The patient's symptoms were relieved after he received CT-guided transforaminal steroid injections. Plain radiographs revealed a radiolucent defect in the articular pillar and cleft at the spinous process of C7. Computed tomography confirmed bilateral spondylolysis and spina bifida occulta of the C7 vertebra. Magnetic resonance imaging revealed absence of edema, which was suggestive of a chronic lesion. Involvement of C7 is not exceptional in a case of cervical spondylolysis. Copyright © 2010 Elsevier Inc. All rights reserved.

  6. A RARE CASE OF BILATERAL MICROSPHEREPHAKIA

    Directory of Open Access Journals (Sweden)

    Pandu

    2015-05-01

    Full Text Available Microspherophakia is rare bilateral congenital anamoly of the crystalline lens. The condition may be isolated , familial or it may be associated with systemic affections like Marfan's syndrome , Weil - Marchesani syndrome , hyperlysinemia and congenital rubella. Microspherophakia results in lenticular myopia , lens dislocation , usually inferiorly and inverse glaucoma. We present a case in a 8 year old child who presented with bilateral microspherophakia and anterior dislocation of lens of right eye. visual acuity in right eye was counting fingers close to face and i n left eye 6/60.IOP with perkins applanation tonometer was 30mmHg in right eye 22mmHg in left eye , cornea was hazy due to edema , anterior chamber was shallow in both eye patient was managed with emergency lens extraction of right eye and secondary ACIOL im plantation. Left eye was managed by laser peripheral iridotomy. IOP was within normal limits postoperatively in both eyes without any antiglaucoma medications. Postoperatively best corrected visual acuity in right was 6/18 and 6/9 in left eye.

  7. Improving efficiency in bilateral emission trading

    International Nuclear Information System (INIS)

    Burtraw, D.; Harrison, K.W.; Turner, P.

    1998-01-01

    When environmental damages from emissions are spatially nonuniform, permit trading has been modeled most often as a 'pollution offset program' in which emission permits are traded between agents, subject to constraints on ambient air quality. To date the institution envisioned to implement such a program involves trading on a bilateral and sequential basis. However, simulation studies indicate that the sequence of trades may alter the outcome and undermine the cost savings from a pollution offset program. This paper identifies a design for the trading institution that tends to overcome this phenomenon and improve the efficiency of equilibria obtained in a simulation model. We model a bilateral trading process for the reduction of sulfur dioxide emissions with a stochastic description of the sequence of trades within groups of nations in Europe. When trading takes place between disaggregated, stylistic representations of economic enterprises, rather than between national governments, a significantly greater portion of potential savings is achieved. In fact, under most sets of assumptions, approximate first order stochastic dominance is achieved wherein the more decentralized the trading agents, the greater the expected savings from a trading program. 4 figs., 2 tabs., 31 refs

  8. Simultaneous bilateral isolated greater trochanter fracture

    Directory of Open Access Journals (Sweden)

    Maruti Kambali

    2013-01-01

    Full Text Available A 48-year-old woman sustained simultaneous isolated bilateral greater trochanteric fracture, following a road traffic accident. The patient presented to us 1 month after the injury. She presented with complaints of pain in the left hip and inability to walk. Roentgenograms revealed displaced comminuted bilateral greater trochanter fractures. The fracture of the left greater trochanter was reduced and fixed internally using the tension band wiring technique. The greater trochanter fracture on the right side was asymptomatic and was managed conservatively. The patient regained full range of motion and use of her hips after a postoperative follow-up of 6 months. Isolated fractures of the greater trochanter are unusual injuries. Because of their relative rarity and the unsettled controversy regarding their etiology and pathogenesis, several methods of treatment have been advocated. Furthermore, the reports of this particular type of injury are not plentiful and the average textbook coverage afforded to this entity is limited. In our study we discuss the mechanism of injury and the various treatment options available.

  9. Noninvasive testing of asymptomatic bilateral hilar adenopathy

    International Nuclear Information System (INIS)

    Carr, P.L.; Singer, D.E.; Goldenheim, P.; Bernardo, J.; Mulley, A.G.

    1990-01-01

    The diagnostic strategy for asymptomatic patients with persistent bilateral bilar adenopathy often involves invasive procedures. The authors used Bayesian analysis to: (1) estimate the relative prevalences of diseases causing bilateral bilar adenopathy; (2) assess changes in the prevalence of disease by race, the presence of other clinical symptoms, and geography; and (3) determine the value of relevant noninvasive tests, including the angiotensin-converting enzyme (ACE) assay, gallium scan, and purified protein derivative (PPD), in order to assess when a strategy of watchful waiting is appropriate. The analysis indicated that the ACE assay, particularly when paired with the PPD, can identify many patients who might safely be managed without immediate invasive biopsy. Patients who are ACE+ and PPD- have an estimated probability of sarcoidosis of 0.95 or greater; patients who are ACE- and PPD+ have a probability of tuberculosis of 0.86 if black, 0.79 if white. In contrast, gallium scanning has no diagnostic role in this clinical situation. Bronchoscopic or mediastinoscopic biopsy has a limited role for patients who are ACE+ PPD- or ACE- PPD+ because of limited sensitivity. Patients who are both ACE- and PPD-, particularly if white, may have a high enough risk of lymphoma to consider invasive biopsy

  10. Bilateral Ovarian Fibrothecoma Associated with Ascites, Bilateral Pleural Effusion, and Marked Elevated Serum CA-125

    Directory of Open Access Journals (Sweden)

    Védi André Serges Loué

    2013-01-01

    Full Text Available Background. The risk of ovarian cancer is increased in the association of ovarian tumor, ascites, and hydrothorax with the significant elevated tumor marker CA-125. However, this association can be observed in a rare clinical and benign pathological entity, that is Demons-Meigs’ syndrome. Objective. To describe a rare case of Demons-Meigs' syndrome observed in our department. Methods. A black African woman of 35 years old, seventh gravida and fourth parous, underwent a total abdominal hysterectomy with bilateral salpingoophorectomy for large bilateral ovarian masses associated with significant ascites, bilateral pleural effusion, and particular highly elevated tumor marker CA-125 (1835 UI/mL in a pronounced general alteration condition. Results. The postoperative course was uneventful characterized by a complete remission of hydrothorax and ascites with normal level of CA-125 three months after tumor excision. Histology of both masses revealed a bilateral ovarian fibrothecoma, a benign tumor of the ovary, thus confirming the diagnosis of Demons-Meigs’ syndrome. Conclusion. The Demons-Meigs syndrome, although it strongly mimics the clinical picture of malignant metastatic ovarian cancer, remains a disease with benign prognosis after surgical tumor resection. This is a rare condition that must be known and recognized by practitioners to avoid unnecessary practices.

  11. Bilateral Free Flap Breast Reconstruction Outcomes: Do Abdominal Scars Affect Bilateral Flaps?

    Directory of Open Access Journals (Sweden)

    Dmytro Unukovych, MD, PhD

    2017-09-01

    Conclusion:. Surgical outcomes of bilateral reconstructions in patients with abdominal scars are generally comparable with ones in patients without prior surgery; however, some problems have been identified. These procedures might have some intraoperative considerations and often require increased operative times. Apart from the traditional preoperative computed tomography angiography, intraoperative imaging (e.g., fluorescence angiography may be advocated in patients with abdominal scars.

  12. Effects of short-term training on behavioral learning and skill acquisition during intraoral fine motor task

    DEFF Research Database (Denmark)

    Kumar, Abhishek; Grigoriadis, Joannis; Trulsson, Mats

    2015-01-01

    Sensory information from the orofacial mechanoreceptors are used by the nervous system to optimize the positioning of food, determine the force levels, and force vectors involved in biting of food morsels. Moreover, practice resulting from repetition could be a key to learning and acquiring a motor...... movements. Thirty healthy volunteers were asked to intraorally manipulate and split a chocolate candy, into two equal halves. The participants performed three series (with ten 10 trials) of the task before and after a short-term (approximately 30min) training. The accuracy of the split and vertical jaw...... task induces behavior learning, skill acquisition and optimization of jaw movements in terms of better performance and reduction in the duration of jaw movements, during the task. The finding of the present study provides insights on into how humans learn oral motor behaviors or the kind of adaptation...

  13. Medicine and ionizing rays: a help sheet in analysing risks in intra-oral dental radiology and applicable texts

    International Nuclear Information System (INIS)

    Gauron, C.

    2009-01-01

    This document proposes a synthesis of useful knowledge for radioprotection in the case of intra-oral dental radiology. In the first part, several aspects are considered: the concerned personnel, the course of treatment procedures, the hazards, the identification of the risk associated with ionizing radiation, the risk assessment and the determination of exposure levels, the strategy to control the risks (reduction of risks, technical measures concerning the installation or the personnel, teaching and information, prevention and medical monitoring), and risk control assessment. A second part indicates the various applicable legal and regulatory texts (European directives, institutions in charge of radioprotection, general arrangements applicable to workers and patients, and regulatory texts concerning worker protection or patient protection against ionizing radiations)

  14. The efficacy of an intraoral fluoride-releasing system in irradiated head and neck cancer patients: a preliminary study.

    Science.gov (United States)

    Meyerowitz, C; Watson, G E

    1998-09-01

    This study compared the anticaries effectiveness of an intraoral fluoride-releasing system, or IFRS, with a standard regimen of daily application of a 1.1 percent neutral sodium fluoride gel in custom trays. Caries protection in subjects in the IFRS group was comparable to that in subjects in the 1.1 percent neutral sodium fluoride group. The subjects all had head or neck cancer and had received radiation therapy, but no more recently than three months before taking part in the study. Overall, IFRS devices were well-tolerated and patient satisfaction was high. The IFRS appears to offer several advantages over the daily application of fluoride gels in custom trays.

  15. Bilateral Testicular Tumors Resulting in Recurrent Cushing Disease After Bilateral Adrenalectomy.

    Science.gov (United States)

    Puar, Troy; Engels, Manon; van Herwaarden, Antonius E; Sweep, Fred C G J; Hulsbergen-van de Kaa, Christina; Kamphuis-van Ulzen, Karin; Chortis, Vasileios; Arlt, Wiebke; Stikkelbroeck, Nike; Claahsen-van der Grinten, Hedi L; Hermus, Ad R M M

    2017-02-01

    Recurrence of hypercortisolism in patients after bilateral adrenalectomy for Cushing disease is extremely rare. We present a 27-year-old man who previously underwent bilateral adrenalectomy for Cushing disease with complete clinical resolution. Cushingoid features recurred 12 years later, with bilateral testicular enlargement. Hormonal tests confirmed adrenocorticotropic hormone (ACTH)-dependent Cushing disease. Surgical resection of the testicular tumors led to clinical and biochemical remission. Gene expression analysis of the tumor tissue by quantitative polymerase chain reaction showed high expression of all key steroidogenic enzymes. Adrenocortical-specific genes were 5.1 × 105 (CYP11B1), 1.8 × 102 (CYP11B2), and 6.3 × 104 (MC2R) times higher than nonsteroidogenic fibroblast control. This correlated with urine steroid metabolome profiling showing 2 fivefold increases in the excretion of the metabolites of 11-deoxycortisol, 21-deoxycortisol, and total glucocorticoids. Leydig-specific genes were 4.3 × 101 (LHCGR) and 9.3 × 100 (HSD17B3) times higher than control, and urinary steroid profiling showed twofold increased excretion of the major androgen metabolites androsterone and etiocholanolone. These distinctly increased steroid metabolites were suppressed by dexamethasone but unresponsive to human chorionic gonadotropin stimulation, supporting the role of ACTH, but not luteinizing hormone, in regulating tumor-specific steroid excess. We report bilateral testicular tumors occurring in a patient with recurrent Cushing disease 12 years after bilateral adrenalectomy. Using mRNA expression analysis and steroid metabolome profiling, the tumors demonstrated both adrenocortical and gonadal steroidogenic properties, similar to testicular adrenal rest tumors found in patients with congenital adrenal hyperplasia, suggesting the presence of pluripotent cells even in patients without congenital adrenal hyperplasia. Copyright © 2017 by the Endocrine Society

  16. Patients' preferences when comparing analogue implant impressions using a polyether impression material versus digital impressions (Intraoral Scan) of dental implants.

    Science.gov (United States)

    Wismeijer, Daniel; Mans, Ronny; van Genuchten, Michiel; Reijers, Hajo A

    2014-10-01

    The primary objective of this clinical study was to assess the patients' perception of the difference between an analogue impression approach on the one hand and an intra-oral scan (IO scan) on the other when restoring implants in the non-aesthetic zone. A second objective was to analyse the difference in time needed to perform these two procedures. Thirty consecutive patients who had received 41 implants (Straumann tissue level) in the non-aesthetic zone in an implant-based referral practice setting in the Netherlands. As they were to receive crown and or bridge work on the implants, in one session, the final impressions were taken with both an analogue technique and with an intraoral scan. Patients were also asked if, directly after the treatment was carried out, they would be prepared to fill out a questionnaire on their perception of both techniques. The time involved following these two procedures was also recorded. The preparatory activities of the treatment, the taste of the impression material and the overall preference of the patients were significantly in favour of the IO scan. The bite registration, the scan head and gag reflex positively tended to the IO scan, but none of these effects were significant. The overall time involved with the IO scan was more negatively perceived than the analogue impression. Overall less time was involved when following the analogue impression technique than with the IO scan. The overall preference of the patients in our sample is significantly in favour of the approach using the IO scan. This preference relates mainly to the differences between the compared approaches with respect to taste effects and their preparatory activities. The patients did perceive the duration of IO scan more negatively than the analogue impression approach. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. pacientes con falla cardiaca

    Directory of Open Access Journals (Sweden)

    Diana Marcela Achury Saldaña

    2007-01-01

    Full Text Available Objetivo: determinar la adherencia al tratamiento de pacientes con falla cardiaca hospitalizados, al aplicar un plan educativo quefomenta el autocuidado.Método: estudio cuasiexperimental (entrevistas enfermera-paciente realizado entre diciembre de 2004 y mayo de 2006, con unamuestra de 50 pacientes seleccionados por conveniencia. Se diseñó un instrumento para evaluar los comportamientos de los pacientes,con base en algunos resultados de la adherencia y sus respectivos indicadores de la taxonomía NOC (Nursing out comes classification. Laadherencia al tratamiento fue medida en dos momentos: el primero durante la hospitalización, seguido de la aplicación del plan educativoantes del alta, que proporcionaba información en el manejo de su enfermedad desde una dimensión física, psicológica y social quepromueve el autocuidado; y el segundo un mes después del alta en su domicilio.Resultados: diferencias estadísticamente significativas (P=0,0001 que demuestran cómo mediante la capacitación al paciente enel manejo de su tratamiento farmacológico y no farmacológico, el establecimiento de una sana relación entre el profesional de enfermeríay el paciente, y la participación de la familia, se logra una total adherencia al tratamiento.Conclusiones: para lograr una adherencia total del paciente con falla cardiaca al tratamiento es necesario un proceso educativo y unseguimiento continuo y personalizado que motive permanentemente al paciente y se le reconozca el papel protagónico en su cuidado y manejo de la enfermedad.

  18. Japan-Australia Security Relations and the rise of China: Pursuing ‘Bilateral-Plus’ Approaches

    Directory of Open Access Journals (Sweden)

    Yusuke Ishihara

    2013-05-01

    Full Text Available Las relaciones de seguridad Japón-Australia han ido profundizándose ostensiblemente en los últimos seis años desde el hito de la Declaración Conjunta sobre Cooperación en Seguridad anunciada en marzo del 2007. Aunque numerosos académicos apuntan al hecho de que es el ascenso de China el principal factor aglutinante en la incipiente asociación, no existen estudios detallados, integrales y actualizados, sobre cómo y porqué la cooperación Japón-Australia, especialmente desde el 2007, ha de relacionarse con sus aproximaciones comunes a China. Este artículo intenta responder argumentando que las estrategias comunes entre Japón y Australia hacia China han de ser entendidas dentro de una perspectiva amplia más allá de los parámetros estrictamente bilaterales, si uno realmente aspira a entender la naturaleza de sus relaciones de seguridad. Aproximaciones de este tipo, teniendo en cuenta una perspectiva más amplia, podrían definirse como 'bilateral-plus', donde Japón y Australia buscan integrar su cooperación bilateral dentro de una fórmula más amplia, ya sea el marco de cooperación trilateral con los EEUU, o esfuerzos de cooperación regional de carácter multilateral.

  19. BILATERAL PATHOLOGICAL HIP DISLOCATION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Yuriy E. Garkavenko

    2017-03-01

    Full Text Available Introduction. Pathological dislocation of the hip is one of the most severe complications of acute hematogenous osteomyelitis. The program of treatment for children with pathological hip dislocation is complex, but it has been sufficiently developed and implemented very successfully. At the same time, the available literature provides no cases of treating children with bilateral pathological hip dislocations after hematogenous osteomyelitis. There is no information on the incidence of such cases or in regards to remote functional results. Materials and methods. The results of the treatment of 18 children with bilateral pathological dislocation of the hip after hematogenous osteomyelitis are presented, which constituted 23.1% of the total number of patients (78 who underwent surgery in 2000–2016 for the diagnosis of pathological hip dislocation. Both hip joints were surgically operated on in 12 patients, while one hip joint was operated on in 6 patients. To assess the anatomical and functional state of hip joints, the clinical and roentgenological diagnostic techniques were used. Results and discussion. To stabilize and restore the function of the hip joints, 18 children underwent 30 surgical interventions: simple open hip reduction (19 and open hip reduction with hip arthroplasty with one (6 or two (5 demineralized osteochondral allogeneic grafts. The decision regarding the possibility of performing surgical intervention on the second hip joint was made only after a child's check-up examination was complete and after positive information about the anatomical and functional state of the operated hip joint was obtained. According to these criteria, 14 (77.8% children underwent surgical treatment of the second hip joint 1–1.5 years after the course of conservative measures to restore the range of motion in the previously operated hip joint. Over a period of 1–12 years, 17 patients were examined, 10 of which underwent an operation on both

  20. Bilateral leukocoria in a patient with homozygous protein C deficiency

    International Nuclear Information System (INIS)

    Khan, Nasrat M.; Al-Dohayan, Noura D.; Al-Batiniji, Fatima S.

    2007-01-01

    We describe a bilateral leukocoria and neonatal purpura fulminans in a male infant, born at full term after an unremarkable pregnancy to a healthy consanguineous married couple. Multiple hemorrhagic skin bullae were found at birth on various parts of the body with bilateral leukocoria, organized vitreous hemorrhage, retinal detachment, and intracranial hemorrhage with undetectable levels of protein C activity. We report a clinical case of homozygous protein-C deficiency with severe purpura fulminans and bilateral leukocoria. (author)