WorldWideScience

Sample records for intracranial wide-necked aneurysms

  1. A novel intracranial enterprise stent together with colis for the treatment of very small intracranial wide-necked aneurysms

    International Nuclear Information System (INIS)

    Huang Haidong; Zhao Kai; Gu Jianwen; Qu Yan; Yang Tao; Xia Xun; Lin Long; Zhang Hui

    2010-01-01

    Objective: To make a preliminary investigation and summary of the technique and efficacy of the novel intracranial stent, Enterprise, together with hydro-detachable coils for the treatment of very small intracranial wide-necked aneurysms (diameter < 3 mm and body-to-neck ratio < 1.5). Methods: Six cases with very small intracranial wide-necked aneurysms were treated with Enterprise stents and hydrodetachable coils. In 5 cases the Enterprise stent was implanted to cover the neck of the aneurysm, which was followed by the introduction of a microcatheter into the aneurysmal sac through the stent mesh to stuff hydrodetachable coils in order to fill the aneurysmal sac. In the remaining case, the microcatheter was placed into the aneurysmal sac before the Enterprise stent was inserted to embolize the aneurysm. Postoperative follow-up was conducted for 3-6 months. Results: The operation was successfully completed in all 6 patients, with the implanted stents being in right place. The parent arteries remained patency in all patients. No complications occurred. Complete occlusion of aneurysmal cavity was obtained in four cases, and the occlusion degree of the aneurysmal cavity above 95% was seen in 2 cases. After the procedure, all the patients recovered well. Neither rebleeding nor symptoms related to thrombosis occurred during a clinic followup of 3-6 months. Conclusion: Endovascular embolization with Enterprise stent together with hydrodetachable coils is a safe and effective method for the treatment of very small intracranial wide-necked aneurysms.However, its long-term effect needs to be further observed. (authors)

  2. Treatment of intracranial wide neck aneurysm with neuroform self-expanding stent combined with spring coils

    International Nuclear Information System (INIS)

    Bai Weixing; Jiang Xifeng; Li Tianxiao; Zhai Shuiting; Xue Jiangyu; Wang Ziliang; Cao Huicun

    2008-01-01

    Objective: To evaluate the preliminary experience of the combined self-expanding neurovascular stent (Neuroform stent) with detachable coils in the management of intracranial wide neck aneurysms. Methods: Self-expanding neurovascular stents with detachable coils were used in treating 27 intracranial wide neck aneurysms of 25 patients including cavernous segment ICA aneurysms in 3, ophthalmic arterial anemysm in 1, PcomA in 18, AcomA in 2, MCAM1 in 1, MCA bifurcation in 1, and basilar trunk in 1. Among them, 2 cases consisted of multi-aneurysms, 2 aneurysms coincide with absolute wide neck (> 4 mm) and 6 with comparatively wide neck (> 7 mm). Nemoform stents were deployed across the neck of aneurysm and detachable coils were released to embolize the aneurysm through stent mesh. Results: Twenty-six Neuroform stents were successfully deployed in 25 patients including 4 Neuroform II stents, and 22 Neurofom III stents(all combined with spring coils). Total occlusion was achieved in 7 patients with residual neck in 9 nearly complete occlusion and partial occlusion in 11. 2 patients were rebleeding and other 2 showed intra-stent thrombosis during the operations. The latter 2 included 1 with post-operative limb paraplegia and 1 died. Still another 1 had transient ischemic attack after the operation. Twenty-three patient recovered well. Twenty-four patients were under clinical followed up from 0.5 to 28 months with an average of 10.8 months. There was no bleeding. Three patients were angiographically followed up for 3-6 months after the procedure, with only 1 case of in-stent thrombosis and no change in other 2 aneurysms with neck remnant. Conclusions: The Neuroform stent is technically feasible and safe for treating intracranial wide neck aneurysms unsuitable for clipping because of its prevention for coil protruding into parent artery. The long term effect still need to be further investigated. (authors)

  3. Sole stenting treatment for small wide-necked saccular intracranial aneurysms:a clinical therapeutic analysis

    International Nuclear Information System (INIS)

    Cheng Jiyong; Hong Bo; Xu Yi; Huang Qinghai; Yang Pengfei; Zhao Wenyuan; Liu Jianmin

    2010-01-01

    Objective: To discuss the feasibility, safety and efficacy of sole stenting technique for the treatment of small wide-necked saccular intracranial aneurysms. Methods: Between February 2001 and November 2009, 36 consecutive patients with small wide-necked saccular intracranial aneurysms (18 males and 18 females, aged 19-75 years,with a mean age of 52.3 years) were treated with stenting technique only. Of 36 patients, the Grade 0 of Hunt and Hess classification was seen in 22,Grade I in 8, Grade II in 5 and Grade III in 1. The aneurysmal diameter ranged from 1.8 mm to 5.0 mm,with a mean diameter of 3.6 mm. The aneurysms were located at the anterior communicating artery (n=1), posterior communicating artery (n=11), intradural paraclinoid internal carotid artery (n=18), basilar artery (n=1), anterior choroidal artery (n=4) or middle cerebral artery (n=1). The clinical manifestations, the angiographic findings and the follow-up observations were analyzed and the results were evaluated by means of the Modified Rankin Scale, magnetic resonance angiography and digital subtraction angiography. Results: Sole stenting treatment was performed in 36 patients with small wide-necked saccular intracranial aneurysms. A total of 37 stents were successfully delivered and deployed at the targeted location. Immediate post-procedural angiography showed that complete occlusion was obtained in one aneurysm, a sluggish intra-aneurysmal vortex motion in 3 aneurysms and a correction of the angle of the parent vessel in two cases, whereas no change was seen in the remaining 30 aneurysms. Angiographic follow-up was carried out in 22 of the 36 patients (61%) during a mean following-up period of 16 months (ranged from 3 to 59 months). The follow-up angiography showed that the complete occlusion was seen in 11 cases, narrowed aneurysmal neck with shrinkage of the aneurysm in 9 cases, narrowed aneurysmal neck only in 1 case, and shrinkage of the aneurysm only in 1 case.All the patients remained

  4. A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Werner; Kuehne, Dietmar [Alfried Krupp Hospital, Department of Radiology and Neuroradiology, Essen (Germany); Bendszus, Martin; Solymosi, Laszlo [University of Wuerzburg, Department of Neuroradiology, Wuerzburg (Germany); Kis, Bernhard [University of Duisburg-Essen, Research Unit, Rheinische Kliniken Essen, Department of Psychiatry and Psychotherapy, Essen (Germany); Boulanger, Thierry [Centre Hospitalier of Luxembourg, Service of Neuroradiology, Luxembourg (Luxembourg)

    2007-07-15

    We report the results of a prospective clinical study using a new self-expanding nitinol stent (Enterprise) designed for the treatment of wide-necked intracranial aneurysms. We treated 31 saccular, wide-necked intracranial aneurysms in 30 patients. Ten aneurysms had recanalized after prior endovascular treatment without a stent, and 21 aneurysms had not been treated before. Stent deployment was successful in all procedures. Additional coil embolization was performed in all aneurysms. Initial complete angiographic occlusion was achieved in 6 aneurysms, a neck remnant was left in 18 aneurysms and there were 7 residual aneurysms. Angiographic follow-up examinations of 30 lesions after 6 months demonstrated 15 complete occlusions, 8 neck remnants and 7 residual aneurysms. One patient refused the 6-month angiographic follow-up. Spontaneous occlusion of the aneurysm had occurred in 14 patients, and 6 aneurysms showed recanalization. Four of these residual aneurysms were retreated. At the 6-month follow-up, 29 parent arteries were unaffected, whereas two parent vessels demonstrated minor asymptomatic narrowing at the stent site. Two patients experienced one or more possible or probable device-related serious adverse events during the 6-month follow-up period. There was no procedural morbidity or mortality at 6 months after the procedure. The reported results demonstrated the safety and feasibility of the Cordis Neurovascular Enterprise stent in the treatment of wide-necked intracranial aneurysms. Initial clinical and angiographic results are favorable. (orig.)

  5. Comparison of CT angiography and digital subtraction angiography in the evaluation of intracranial aneurysmal neck

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Baik, Seung Kug; Shin, Mi Jeong; Choi, Han Yong

    2001-01-01

    To compare the usefulness of three-dimensional multislice CT angiography(CTA) and digital subtraction angiography (DSA) in the evaluation of intracranial aneurysmal neck. Nineteen patients with intracranial aneurysm (23 cases) underwent DSA and subsequent CTA. Using a multislice CT scanner and the SSD(shaded surface display) technique, clipping, cutting and the MPR technique, three-dimensional images were obtained. These were (a) external, (b) internal, from the direction of the parent artery, (c) internal, from the direction of the aneurysmal dome, and (d) an aneurysmal cutting image. The CTA findings were retrospectively compared with the DSA images. Twenty aneurysms were small and three were large. In eleven cases aneurysm neck was small, in nine it was wide, and in three it was relatively wide. For aneurysmal neck evaluation, CTA was superior to DSA in six of nine wide-neck aneurysms and all three large-sized wide-neck aneurysms. In small neck aneurysms 8 of 11 cases and in relatively wide neck all 3 cases showed similarly good images by both modalities. Of the 23 cases demonstrated by four different images, 14 cases showed the best image in internal image from parent artery direction and 6 cases showed similarly good image in both aneurysmal cutting image and internal image from parent artery direction. In the evaluation of wide neck aneurysms, 7 of 9 cases showed the best image at internal image from parent artery direction, compared with other three different images. In two cases of aneurysms, calcification was visible in the aneurysmal wall, so it was difficult to evaluate the aneurysmal neck. CTA was superior to DSA in the evaluating the intracranial aneurysmal neck. CTA maybe an additional available modality to evaluate the aneurysmal neck which is difficult to detect by the DSA. And the information of intracranial aneurysmal neck through CTA will be of value in surgical and endovascular treatment

  6. Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: mid-term and long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Sedat, Jacques; Chau, Yves; Mondot, Lydiane [CHU Nice, Unite de Neurointerventionnelle, Hopital St. Roch, Nice (France); Vargas, Julian; Szapiro, Jacek; Lonjon, Michel [CH Bastia, Service de Neurochirurgie, Bastia (France)

    2009-06-15

    Coiling associated with placement of self-expandable intracranial stents has amplified the treatment of intracranial wide-necked aneurysms, but the durability of this treatment and the existence of delayed recurrence are not yet well known. The purpose of this report is to present our experience with the Neuroform Stent associated with coiling and to evaluate complications, effectiveness, and long-term results of this technique. A retrospective study of 42 patients with wide-necked cerebral aneurysms treated with the Neuroform Stent was performed. Mean aneurysm size was 11.3 mm. Mean neck size was 5.33 mm. All patients were treated with coiling and stenting. Clinical and angiographic follow-up was available in 38 patients (90.5%). The overall follow-up time ranged from 6 months to 5 years (mean, 42 months), but most of the patients (92%) had a follow-up period superior to 1 year. Successful deployment of 41 stents (97%) was obtained. Permanent procedural morbidity was observed in only one patient (2.4%). Long-term complete aneurysmal occlusion was obtained in 27 patients (71%). Aneurysmal regrowth was observed in four patients (9.5%) on the first control angiogram. After the first control angiogram, no delayed recanalization or regrowth was observed. During the follow-up period, there were no hemorrhagic events, no delayed thrombosis, and no stent displacement. Our results demonstrate the effectiveness of the technique, a small rate of procedural complications, and long-term tolerance of the Neuroform Stent. Despite some evidence of early aneurysmal recurrence, long-term durability of stent-assisted aneurysm occlusion is stable after the first year. (orig.)

  7. Use of triple microcatheters for endovascular treatment of wide-necked intracranial aneurysms: A single center experience

    International Nuclear Information System (INIS)

    Cho, Young Dae; Rhim, Jong Kook; Kang, Hyun Seung; Kim, Jeong Eun; Cho, Won Sang; Han, Moon Hee; Park, Jeong Jin; Jeon, Jin Pyeong

    2015-01-01

    The dual microcatheter technique is common practice for coil embolization of a wide-necked aneurysm, due to safety and efficacy. However, technical limitations of some complex configurations may necessitate additional microcatheters to bolster coil stability, compact the coil, or for protection. Described herein is a triple microcatheter technique for endovascular management of wide-necked intracranial aneurysms. Data accruing prospectively between January 2006 and October 2014 on simultaneously executed triple microcatheter coil embolization procedures done in 38 saccular aneurysms were reviewed. Clinical and morphological outcomes were assessed, with emphasis on technical aspects of treatment. The triple microcatheter technique was successfully applied to all 38 saccular aneurysms, involving the posterior communicating artery (n = 13), the middle cerebral artery (n = 10), the basilar tip (n = 7), the anterior cerebral artery (n = 5), and the internal carotid artery (n = 3). Stent protection was added in four patients and balloon remodeling in one. Dual microcatheters (n = 24) were usually deployed to deliver the coil within sacs of aneurysms, with the additional microcatheter used for protection. Otherwise, triple microcatheters were deployed for coil delivery (n = 11) or coils were delivered via a single microcatheter, with dual microcatheters deployed for protection (n = 3). Successful occlusion of aneurysms was achieved in 89.5% of cases, with no procedure-related morbidity or mortality. Stable occlusion was maintained in 72.2% (26/36) of the aneurysms at the final follow-up (mean interval, 30.2 ± 22.7 months). The outcomes of this limited study suggest that the triple microcatheter technique may be an effective and safe therapeutic option for wide-necked aneurysms, using technical strategies tailored to complex angio-anatomic configurations

  8. The LVIS Jr. microstent to assist coil embolization of wide-neck intracranial aneurysms: clinical study to assess safety and efficacy

    International Nuclear Information System (INIS)

    Moehlenbruch, M.; Herweh, C.; Behrens, L.; Jestaedt, L.; Bendszus, M.; Pham, M.; Amiri, H.; Ringleb, P.A.

    2014-01-01

    This study was aimed to assess clinical safety and efficacy of the LVIS Jr. microstent in stent-assisted coil embolization of wide-neck intracranial aneurysms. IRB approved single-center interventional clinical study in 22 patients (10 females, 12 males, mean age 55, age range 33-74 years) for the endovascular treatment of wide-neck aneurysms. After obtaining informed consent, patients were included according to the following criteria: aneurysm fundus-to-neck ratio 4 mm, and a parent vessel diameter of ≤3.5 mm. Primary end point for clinical safety was absence of death, absence of major or minor stroke, and absence of transient ischemic attack. Primary end point for treatment efficacy was complete angiographic occlusion according to the Raymond-Roy Occlusion Classification (RROC) immediately after the procedure and at follow-up after 3 and 6 months on magnetic resonance imaging (MRI). In 20/22 (91 %) of patients, the primary end point of safety was reached; in the two remaining patients, transient ischemic attack, but no permanent deficit was observed; in 16/22 (73 %), efficient occlusion (RROC1) was reached, and in 6/22 (27 %), a residual neck remained (RROC2). Single [seven with antegrade, two in crossover configuration, and four with ''first-balloon-then-stent'' (FBTS) technique] or double-stent (eight patients with Y configuration and one patient with X configuration) deployment was technically successful in all cases. Deployment of the LVIS Jr. microstent in various single- or double-stent configurations is safe and effective to assist the treatment of intracranial wide-neck aneurysms. (orig.)

  9. The Barrel vascular reconstruction device for endovascular coiling of wide-necked intracranial aneurysms: a multicenter, prospective, post-marketing study.

    Science.gov (United States)

    Gory, Benjamin; Blanc, Raphaël; Turjman, Francis; Berge, Jérôme; Piotin, Michel

    2018-02-02

    The Barrel vascular reconstruction device (Barrel VRD) is a novel stent with design features that allow endovascular coiling of wide-necked bifurcation aneurysms while preserving adjacent branches, without necessitating dual stent implantation. This study aimed to assess the safety and effectiveness of the Barrel VRD at 12-month follow-up. The Barrel VRD trial is a prospective, multicenter, observational post-marketing registry evaluating the use of the Barrel VRD for treatment of wide-necked bifurcation aneurysms. The primary effectiveness endpoint was successful aneurysm treatment measured by digital subtraction angiography with a Raymond-Roy occlusion grade of 1 or 2 in the absence of retreatment, parent artery stenosis (>50%), or target aneurysm rupture at 12 months. The primary safety endpoint was the absence of neurological death or major stroke at 12 months. Twenty patients were enrolled from December 2013 to December 2014. The device was implanted in 19 patients with 19 aneurysms (8 middle cerebral artery, 4 anterior communicating artery, 1 internal carotid artery terminus, 4 basilar artery aneurysms; mean dome height 5.7±1.91 mm; mean neck length 4.8±1.35 mm, mean dome-to-neck ratio 1.6±2.0). Coiling was performed in all cases. The primary effectiveness endpoint was achieved in 78.9% of subjects (15/19; 12 complete occlusions, 3 neck remnants), and the primary safety endpoint was 5.3% (1/19). This prospective study demonstrates that the Barrel VRD device resulted in ~80% occlusion rates and ~5% rates of neurological complications at 1 year after endovascular treatment of wide-necked bifurcation intracranial aneurysms. REGISTERED CLINICAL TRIAL: NCT02125097;Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Enterprise stent-assisted coiling for wide-necked intracranial aneurysms during ultra-early (48hours) subarachnoid hemorrhage: a single-center experience in 59 consecutive patients.

    Science.gov (United States)

    Liu, Aihua; Peng, Tangming; Qian, Zenghui; Li, Youxiang; Jiang, Chuhan; Wu, Zhongxue; Yang, Xinjian

    2015-10-01

    Accumulated experience and improvement of stents dedicated to intracranial use have significantly widened the applicability of stent-assisted coiling (SAC) to ruptured wide-necked aneurysms. This retrospective study was designed to evaluate the safety and efficacy of SAC using the Enterprise stent for ruptured wide-necked intracranial aneurysms during ultra-early subarachnoid hemorrhage. We reviewed data from 59 consecutive patients with ruptured wide-necked aneurysms who had SAC using the Enterprise stent performed within 48hours of onset. Data collected and analyzed included: patient demographics; morphologic features of the aneurysm; treatment results and follow-up results. Clinical outcomes were evaluated by modified Rankin Scale (mRS). In all 59 cases, SAC using the Enterprise stent was performed successfully, with no significant technical difficulties. Initial angiographic results were: complete occlusion in 38 cases; near occlusion in 17; and partial occlusion in four. Angiographic follow-up of 48 patients showed that 46 (95.8%) remained stable or improved, without regrowth, while regrowth was imaged in two patients. Medium-term clinical follow-up of 54 patients (mean, 26.9months) showed that 88.9% had a good outcome (mRS: 0 in 34; 1 in eight; and 2 in six), and 11.1% poor outcomes (mRS: 3 in four; and 4 in two). Enterprise SAC is a safe and viable option for treatment of ruptured wide-necked aneurysms within 48hours of ictus. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  11. Turnover in intracranial aneurysm phantoms: its relation to neck size

    International Nuclear Information System (INIS)

    Chung, Tae Sub; Lee, Young Jun; Rhim, Yoon Chul

    2003-01-01

    To evaluate the physiologic background of aneurysms poorly visualized during 3D-TOF MRA, contrast-enhanced MRA (CEMRA) and DSA due to hemodynamic isolation. Using handmade elastic silicon phantoms to represent terminal basilar tip aneurysms, 3D-TOF MRA, CEMRA and DSA were used to determine blood turnover. Aneurysmal neck size was 2 mm and 10 mm, and the use of a pulsatile pump also helped recreate human physiologic parameters. We compared the results with those of computational fluid dynamics. DSA images of the narrow-necked aneurysm showed that a small volume of contrast medium washed into it during the systolic phase. As the width of its neck increased, the turnover volume of fragments of contrast bolus also increased. At CEMRA, the broad-necked aneurysm was visualized as the main bolus of Gd-DTPA passed through it, and at delayed CEMRA, the narrow-necked aneurysm was visualized faintly after the passage of bolus Gd-DTPA. The results correlated closely with those of 3D-TOF MRA and computational fluid dynamics. The visualization of intracranial aneurysms at 3D-TOF MRA, CEMRA and DSA was greatly dependent upon blood turnover, which varied according to aneurysmal neck size. A narrow-necked aneurysm might be missed at 3D-TOF MRA, CEMRA and DSA due to hemodynamic isolation

  12. Endovascular treatment of wide-necked aneurysms using stents combined with electrolytic detachable coils in a canine model

    International Nuclear Information System (INIS)

    Liu Jianmin; Zhang Xin; Zhou Xiaoping; Hong Bo; Xu Yi; Huang Qinghai; Zhang Long; She Jiagui; Zhao Rui

    2004-01-01

    Objective: To assess hemodynamics and histology of the aneurysms by treating experimental wide-necked aneurysms endovascularly with a combination of stents and electrolytic detachable coils. Methods: An experimental model was surgically constructed in the necks of six canines for simulating intracranial wide-necked aneurysms. Balloon-expandable metal stents were positioned across the aneurysms in bilateral carotid arteries of six canines with additional intraaneurysmal placement of detachable microcoils in only unilateral carotid artery of each canine. Sonography and angiography were performed in different stages and histologic examinations were achieved finally. Results: Stent placement was successful in all six canines. Aneurysms treated with only stents placement showed no significant thrombus formation with slow growing of neointima over the neck of the aneurysm. Thrombosis occurred in the aneurysms treated with stents and coils in a short time and neointima covered the neck of the aneurysms completely. Conclusions: Endovascular treatment of wide-necked aneurysms using stents combined with electrolytic detachable coils may prevent re-rupture of the aneurysms and promote neointima formation over the neck of the aneurysms. (authors)

  13. Usefulness of virtual endoscopy for evaluating the relationship between the neck of intracranial aneurysm and surrounding vessels

    International Nuclear Information System (INIS)

    Ikeda, Jota; Horie, Hitoshi; Ishikura, Reiichi; Ando, Kumiko; Morikawa, Tsutomu; Tominaga, Satoru; Nakao, Norio

    2000-01-01

    Application of three-dimensional CT virtual endoscopy for evaluation of the neck and surrounding vessels of intracranial aneurysms. 3D-CT virtual endoscopy (VE) is a reconstructed image using computer processing of 3D-CT images. We evaluated the usefulness of a virtual endoscopy to analyze the relationship between the neck of an intracranial aneurysm and the surrounding vessels. Eight cases with intracranial aneurysms underwent digital subtraction angiography (DSA) and enhanced CT with transarterial infusion of contrast media. 3D-CT angiogram (3D-CTA) and virtual endoscopic images were obtained from the CT image data sets using surface rendering method. The relationship between the neck of an intracranial aneurysm and the surrounding vessels was confirmed by operation or IVR. VE clearly visualized the neck and surrounding vessels in all cases. Operation/IVR findings agreed with the virtual endoscopic findings in all cases, but not with the DSA or 3D-CTA findings in 4 and 2 cases, respectively. 3D-CTA and virtual endoscopy clearly visualizes the relationship between cerebral aneurysms and surrounding vessels, which is useful for determining IVR procedures. (author)

  14. Endovascular stenting for treatment of complex intracranial aneurysms: preliminary outcome

    International Nuclear Information System (INIS)

    Huang Qinghai; Liu Jianmin; Xu Yi; Hong Bo; Zhao Wenyuan; Zhou Xiaoping

    2004-01-01

    Objective: To summarize the technique and efficiency of combined endovascular stenting and Guglielmi detachable coils (GDC) packing for the treatment of intracranial wide-necked bifurcation aneurysms and recanalized aneurysms. Methods: The coronary stents were implanted across the necks of 5 intracranial wide-necked aneurysms (two at bifurcation of ICA, one at basilar artery and two recanalized PcoA aneurysms). The porous stents covered the ostia of vital side branches and perforating vessels in three cases. Microcatheters were introduced into the aneurysmal sac through the stent mesh and then followed by GDCs embolizing the aneurysms. Results: The stents were deployed in parent artery in all cases. Total occlusion was obtained in 4 cases, while more than 90% in one case with patency of the parent arteries and vital perforating arteries. Follow-up angiography performed in all patients 3-6 months later revealed no intrastent stenosis. All the patients recovered well except III nerve palsy in one patient which diminished 3 months later. Conclusion: Endovaseular therapy combined stent implantation and microcoil placement maybe a valid alteration for the treatment of wide-necked bifurcation aneurysms and recanalized aneurysms, which shows promise clinical application in the future. The ostia of vital side branches covered with stents showed no effect on hemodynamics. (authors)

  15. Stent-assisted coil embolization of intracranial aneurysms: a single center experience.

    Science.gov (United States)

    Luo, Chao-Bao; Teng, Michael Mu-Huo; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo; Chang, Cheng-Yen

    2012-07-01

    Endovascular detachable coil embolization has become an important method in the management of intracranial aneurysms. However, coil embolization alone may fail to treat some wide-neck aneurysms. Herein, we report our experience with and outcome of stent-assisted coil embolization (SACE) of intracranial aneurysms. Over a 5-year period, a total of 59 patients diagnosed with 63 intracranial aneurysms underwent SACE. Of the total 63 aneurysms, 6 aneurysms were treated by SACE as a salvageable procedure because of coil instability after detachment. There were 17 men and 42 women enrolled in the study, with ages ranging from 24 to 86 years (mean: 60 years). We retrospectively assessed the clinical data, aneurysm characteristics, and angiographic and clinical outcomes of all patient cases. The mean aneurysm size was 9.4 mm, and the mean neck size was 5.5 mm. Clinical and angiographic follow-up exceeding 6 months were available in 51 and 40 patients, respectively. The mean clinical follow-up time was 28 months (range: 6-49 months). Successful stent deployment was found in 60 aneurysms (95%). Midterm total or subtotal angiographic aneurismal occlusion was obtained in 56 aneurysms (89%), with further thrombosis of the aneurismal sac occurring in 4 (10%). Stable coiling aneurysm was found in 24 (78%), aneurysm recurrence was observed in 5 (13%), and permanent procedural morbidity was observed in two patients (3.4%). During the follow-up period, there were no hemorrhagic events and no stent displacement. Despite a modest procedural complication rate, and some evidence of aneurismal recurrence, SACE was proved to be both effective and safe in managing wide-neck intracranial aneurysms. Our results also demonstrated the midterm durability and stability of aneurysm treated by SACE. Furthermore, SACE can be a salvageable procedure in cases with coil instability after detachment. Copyright © 2012. Published by Elsevier B.V.

  16. Double microcatheter technique for coiling intracranial aneurysms with unfavorable configurations

    Directory of Open Access Journals (Sweden)

    WANG Shu-yuan

    2013-03-01

    Full Text Available Background Although stent-assisted technique has been widely used clinically, it is still hard to perform coiling treatment for complicated intracranial aneurysms, including relatively wide-necked tiny aneurysms and lobulated wide-necked aneurys ms with important branch vessels arising from the neck. This study aims to investigate the feasibility and clinical results of endovascular treatment for intracranial aneurysms with unfavorable configurations by using double microcatheter technique. Methods Thirty-three cases with complicated aneurysms were treated by using double microcatheter technique from April 2008 to November 2012. The locations of these aneurysms were anterior communicating artery (7 cases, posterior communicating artery (14 cases, ophthalmic artery (3 cases, anterior choroidal artery (3 cases, origin of posterior inferior cerebellar artery (3 cases, bifurcation of middle cerebral artery (2 cases and top of basilar artery (1 case. The mean neck- to-body (width ratio was 0.80 ± 0.21 (0.53-1.33. The mean body (width-to-dome (height ratio was 1.12 ± 0.37 (0.55-2.12. The mean dome (height-to-neck ratio was 1.26 ± 0.41 (0.65-2.96. The diameter of neck ≥4 mm was seen in 7 aneurysms, neck≥height in 9 and neck ≥width in 8. Besides, there were 9 very small aneurysms (the maximum diameter≤3 mm and 13 aneurysms with important branch vessels arising from the neck. All of these aneurysms were treated with coiling by using double microcatheter technique. Results All aneurysms were successfully embolized. Immediate postembolization angiography showed no residual contrast filling in 19 aneurysms, and residual filling in 14. There were some small loops protruding from the neck without influencing the blood flow in 12 cases. At discharge, according to modified Rankin Scale (mRS, 30 patients with 0-1 scores presented excellent clinical outcomes and 3 patients with 2 scores had cognitive dysfunction and moderate disability due to vasospasm

  17. Stent implantation for the treatment of wide-necked aneurysms located at internal carotid artery bifurcation

    International Nuclear Information System (INIS)

    Xing Ming; Yang Pengfei; Huang Qinghai; Zhao Wenyuan; Hong Bo; Xu Yi; Liu Jianmin

    2012-01-01

    Objective: To preliminarily evaluate the feasibility, safety and efficacy of stent placement for the treatment of wide-necked aneurysms located at internal carotid artery bifurcation. Methods: Eleven patients with wide-necked aneurysms located at internal carotid artery bifurcation, who were encountered during the period from Jan. 2004 to Dec. 2010 in hospital, were collected. A total of 16 intracranial aneurysms were detected, of which 11 were wide-necked and were located at internal carotid artery bifurcation. The diameters of the aneurysms ranged from 2.5 mm to 18 mm. Individual stent type and stenting technique was employed for each patient. Follow-up at 1, 3, 6 and 12 months after the procedure was conducted. Results: A total of 11 different stents were successfully deployed in the eleven patients. The stents included balloon expandable stent (n=1) and self-expanding stent (n=10). According to Raymond grading for the immediate occlusion of the aneurysm, grade Ⅰ (complete obliteration) was obtained in 4, grade Ⅱ (residual neck) in 2 and grade Ⅲ (residual aneurysm) in 5 cases. No procedure-related complications occurred. At the time of discharge, the modified Rankin score was 0-1 in the eleven patients. During the follow-up period lasting for 1-108 months, all the patients were in stable condition and no newly-developed neurological dysfunction or bleeding observed. Follow-up examination with angiography (1-48 months) showed that the aneurysms were cured (no visualization) in 4 cases, improved in 2 cases and in stable condition in one case. Conclusion: For the treatment of wide-necked aneurysms located at internal carotid artery bifurcation, stent implantation is clinically feasible, safe and effective. Further studies are required to evaluate its long-term efficacy. (authors)

  18. Follow-up observation of intracranial aneurysms with Guglielmi detachable coil embolization

    International Nuclear Information System (INIS)

    Li Minghua; Cheng Yingsheng; Gu Binxian; Chen Junyan; Wang Wu; Xu Tao; Xu Shiding; Liu Jianmin; Xu Yi

    2002-01-01

    Objective: To evaluate the middle-long term efficacy of intracranial aneurysms with Guglielmi detachable Coil (GDC) embolization. Methods: 131 cases with 134 aneurysms were embolized with GDC. Of them, 39 aneurysms were in the anterior communication artery, 45 in the posterior communication artery, 19 in the siphon segment of internal carotid artery, 14 in the mediate cerebral artery, 3 in the anterior cerebral artery, 9 in the posterior circle and 5 in other. A wide-neck (neck > 4 mm, or aneurysm body/neck 2 = 8.643, P < 0.01. Follow-up DSA showed no change in 118 aneurysms which were a total or nearly total occlusion on post-embolization DSA. In 16 aneurysms with subtotal or partial occlusion, re-open of aneurysm showed in 9 cases, reduced in 3, no change in 4 on follow-up DSA. Conclusion: Although the recent-medium-term efficacy of intracranial aneurysms with GDC embolization is in the affirmative, a period follow-up DSA is essential, especially in aneurysms with subtotal or partial occlusion. Again, re-embolization with GDC is recommended in a re-open aneurysm

  19. Reverse waffle cone technique in management of stent dislodgement into intracranial aneurysms.

    Science.gov (United States)

    Luo, Chao-Bao; Lai, Yen-Jun; Teng, Michael Mu-Huo; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo

    2013-09-01

    Stent-assisted coil embolization (SACE) is a common method to manage intracranial wide-neck aneurysm. Using this technique, a stent must be successfully deployed into the parent artery to cross the aneurysm neck. We describe the reverse waffle cone technique in management of intra-procedural stent dislodgement during SACE of internal carotid artery (ICA) wide-neck aneurysms. Two patients with unruptured wide-neck ICA aneurysms underwent SACE. Intra-procedural forward stent migration occurred during catheterization with proximal stent dislodgement and migration into the aneurysm sac. Navigation of a second stent to bridge the aneurysm neck failed in one patient because the second stent was impeded by the dislodged stent. Using the reverse waffle cone technique, a microcatheter was navigated into the aneurysm sacs. Coils were safely detached into each aneurysm sac without any device assistance. The two wide-neck aneurysms were successfully treated with preservation of flow to the internal carotid arteries. The complication of intra-procedural distal stent migration and dislodgement, with proximal stent prolapse into an aneurysm sac, may not result in a failure to coil the aneurysm. The reverse waffle cone technique provides an effective treatment in the management of this complication. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Y stenting assisted coiling using a new low profile visible intraluminal support device for wide necked basilar tip aneurysms: a technical report.

    Science.gov (United States)

    Conrad, Marcelo D; Brasiliense, Leonardo B C; Richie, Alexa N; Hanel, Ricardo A

    2014-05-01

    Many endovascular techniques have been described in recent years for the management of wide necked aneurysms. The Y stent assisted technique has been generally used for coil embolization of wide necked bifurcation aneurysms. This technique was first described for the treatment of basilar tip aneurysms in combination with several different devices, demonstrating encouraging results. We report the results of the first two cases of wide necked basilar tip aneurysms treated with Y stent assisted coil embolization using a new low profile visible intraluminal stent (LVIS Jr; MicroVention, Tustin, California, USA) delivered through a 0.017 inch microcatheter. We also reviewed the literature comparing other endovascular techniques (coiling alone, stent assisted coiling, and Y stent assisted coiling) for wide necked aneurysms. The LVIS Jr device offers a new option for the treatment of these challenging lesions, with clear advantages over currently available intracranial stents. Larger series and long term results are needed to confirm the applicability and durability of this technique/technology.

  1. Angle change of the parent arteries after stent-assisted coil embolization of wide-necked intracranial bifurcation aneurysms

    International Nuclear Information System (INIS)

    Cho, W.-S.; Kang, H.-S.; Kim, J.E.; Kwon, O.-K.; Oh, C.W.; Cho, Y.D.; Han, M.H.

    2014-01-01

    Aim: To investigate the angle changes of the parent arteries after stent-assisted coil embolization of wide-necked intracranial bifurcation aneurysms. Materials and methods: The adjacent parent arterial angles before and after stent-assisted coil embolization were measured in 38 patients with aneurysms of the anterior communicating artery (ACoAA) and 41 patients with bifurcation aneurysms of the middle cerebral artery (MCABA). Variables were analysed in relation to the angle changes. Results: Vascular angles of the parent arteries significantly increased by 27.8° (±18.5°) immediately after stent-assisted coil embolization in 79 cases (p < 0.001), with 25.7° (±14.8°) in ACoAA and 29.7° (±21.4°) in MCABA, respectively. In 51 (64.6%) cases with follow-up angiography (mean interval 13.5 ± 4.1 months), vascular angles increased by 27.2° (±17.1°) immediately after treatment and further increased by 20.7° (±14.3°) at the last follow-up (all p < 0.001). More acute pre-stent angles of the parent arteries correlated with greater post-stent angle changes (p = 0.006). Younger age tended to be inversely related to post-stent angle changes (p = 0.091). Conclusion: Stent placement during coil embolization induced significant changes in the aneurysm–parent artery relationship. Further study is needed to elicit the association between angle change of the parent arteries and aneurysmal stability after coil embolization

  2. Stent-assisted coiling of wide-neck bifurcation aneurysms with a branch incorporated in the aneurysm base: long-term follow-up in 49 patients with 53 aneurysms.

    Science.gov (United States)

    Lubicz, Boris; Morais, Ricardo; Bruyère, Pierre-Julien; Ligot, Noémie; Mine, Benjamin

    2017-06-01

    Wide-neck bifurcation intracranial aneurysms (WNBA) with a branch incorporated in the aneurysm base remain difficult to treat by embolization. We aim to report our long-term follow-up of stent-assisted coiling (SAC) in this subgroup of patients. This study was approved by our local ethical committee. A retrospective review of our prospectively maintained database identified all patients treated in our institution by SAC for a WNBA with a branch incorporated in the aneurysm base. Technical issues, immediate, long-term outcomes were evaluated. Between 2007 and 2015, 49 patients with 53 intracranial aneurysms (IAs) (52 unruptured, 1 ruptured) were identified and successfully treated. No morbidity/mortality occurred. The incorporated branch was preserved in all patients but one who was treated during a vasospasm phase. At the first 6-month imaging control, the branch was patent. Immediate occlusion was near-complete in 11/53 aneurysms (20.8%), neck remnant in 20/53 aneurysms (37.7%), and incomplete in 22/53 aneurysms (41.5%). Available imaging follow-up of 47 IAs, ranging from 3 to 84 months (mean 26 months ± 19.6 months), showed 27 progressive thrombosis (57.4%), 17 stable occlusions (36.2%), 1 minor recanalization (2.1%), and 2 significant recanalizations that were retreated (4.3%). The latest imaging control showed 30 near-complete occlusions (63.8%), 13 neck remnants (27.7%), and 4 incomplete occlusions (8.5%). Stent-assisted coiling is safe and effective for the treatment of WNBA with a branch incorporated in the aneurysm base. Despite poor immediate anatomical results, long-term follow-up shows a high rate of progressive thrombosis achieving adequate and stable occlusion in most patients.

  3. Stent-assisted coil embolization of intracranial aneurysms: A single center experience

    Directory of Open Access Journals (Sweden)

    Chao-Bao Luo

    2012-07-01

    Conclusion: Despite a modest procedural complication rate, and some evidence of aneurismal recurrence, SACE was proved to be both effective and safe in managing wide-neck intracranial aneurysms. Our results also demonstrated the midterm durability and stability of aneurysm treated by SACE. Furthermore, SACE can be a salvageable procedure in cases with coil instability after detachment.

  4. WEB-DL endovascular treatment of wide-neck bifurcation aneurysms

    DEFF Research Database (Denmark)

    Lubicz, B; Klisch, J; Gauvrit, J-Y

    2014-01-01

    BACKGROUND AND PURPOSE: Flow disruption with the WEB-DL device has been used safely for the treatment of wide-neck bifurcation aneurysms, but the stability of aneurysm occlusion after this treatment is unknown. This retrospective multicenter European study analyzed short- and midterm data...... in patients treated with WEB-DL. MATERIALS AND METHODS: Twelve European neurointerventional centers participated in the study. Clinical data and pre- and postoperative short- and midterm images were collected. An experienced interventional neuroradiologist independently analyzed the images. Aneurysm occlusion...... was classified into 4 grades: complete occlusion, opacification of the proximal recess of the device, neck remnant, and aneurysm remnant. RESULTS: Forty-five patients (34 women and 11 men) 35-74 years of age (mean, 56.3 ± 9.6 years) with 45 aneurysms treated with the WEB device were included. Aneurysm locations...

  5. Stenting is improving and stabilizing anatomical results of coiled intracranial aneurysms

    International Nuclear Information System (INIS)

    Lubicz, Boris; Bandeira, Alexandra; Baleriaux, Danielle; Bruneau, Michael; Witte, Olivier de; Dewindt, Aloys

    2009-01-01

    Stent-assisted coiling (SAC) is an alternative to surgical clipping for the treatment of wide-necked intracranial aneurysms (IA). However, little information is available concerning the long-term results of this treatment. The aim of this study was to report the long-term clinical and anatomical findings in 32 patients with 34 wide-necked IA treated by SAC. A retrospective review of our prospectively maintained database identified all patients followed up for wide-necked IA treated by SAC. The clinical charts, procedural data, and angiographic results were reviewed. Thirty-two patients with 34 IA were identified including 25 asymptomatic patients, four with cranial nerve palsies, two with a subarachnoid hemorrhage, and one with transient ischemic attacks. Mean aneurysm size was 10.2 mm (range 3.5 to 26 mm). Embolization was successful in all patients and no procedure-related neurological morbidity or mortality was observed. Immediate anatomical results included nine complete occlusions (26.5%), two neck remnants (6%), and 23 incomplete occlusions (67.5%). Mean imaging follow-up of 20 months showed 18 further thrombosis (53%) and 16 stable results (47%). Finally, 27 aneurysms were completely occluded (79%), three had a neck remnant (9%), and four were incompletely occluded (12%). Asymptomatic and nonsignificant in-stent stenosis occurred in seven patients (22%). SAC is safe and effective for the treatment of wide-necked IA. Despite unsatisfying immediate aneurysm occlusion, the adjunctive effect of the stent is stabilizing or significantly improving long-term anatomical results. (orig.)

  6. Closed-cell stent for coil embolization of intracranial aneurysms: clinical and angiographic results.

    Science.gov (United States)

    Wakhloo, A K; Linfante, I; Silva, C F; Samaniego, E A; Dabus, G; Etezadi, V; Spilberg, G; Gounis, M J

    2012-10-01

    Recanalization is observed in 20-40% of endovascularly treated intracranial aneurysms. To further reduce the recanalization and expand endovascular treatment, we evaluated the safety and efficacy of closed-cell SACE. Between 2007 and 2010, 147 consecutive patients (110 women; mean age, 54 years) presenting at 2 centers with 161 wide-neck ruptured and unruptured aneurysms were treated by using SACE. Inclusion criteria were wide-neck aneurysms (>4 mm or a dome/neck ratio ≤ 2). Clinical outcomes were assessed by the mRS score at baseline, discharge, and follow-up. Aneurysm occlusion was assessed on angiograms by using the RS immediately after SACE and at follow-up. Eighteen aneurysms (11%) were treated following rupture. Procedure-related mortality and permanent neurologic deficits occurred in 2 (1.4%) and 5 patients (3.4%), respectively. In total, 7 patients (4.8%) died, including 2 with reruptures. Of the 140 surviving patients, 113 (80.7%) patients with 120 aneurysms were available for follow-up neurologic examination at a mean of 11.8 months. An increase in mRS score from admission to follow-up by 1, 2, or 3 points was seen in 7 (6.9%), 1 (1%), and 2 (2%) patients, respectively. Follow-up angiography was performed in 120 aneurysms at a mean of 11.9 months. Recanalization occurred in 12 aneurysms (10%), requiring retreatment in 7 (5.8%). Moderate in-stent stenosis was seen in 1 (0.8%), which remained asymptomatic. This series adds to the evidence demonstrating the safety and effectiveness of SACE in the treatment of intracranial aneurysms. However, SACE of ruptured aneurysms and premature termination of antiplatelet treatment are associated with increased morbidity and mortality.

  7. Therapeutic effect of enterprise stent-assisted embolization for very small ruptured intracranial aneurysms.

    Science.gov (United States)

    Qin, Feiyun; Li, Zhenbao; Fang, Xinggen; Zhao, Xintong; Liu, Jiaqiang; Wu, Degang; Lai, Niansheng

    2017-08-01

    Enterprise stent has been widespread used in wide-necked intracranial aneurysms and good efficacy has been achieved, but there are few reports on its applications in very small ruptured intracranial aneurysms in literatures. This study aimed to evaluate the safety and efficacy of Enterprise stent-assisted coiling embolization of very small ruptured intracranial aneurysms.We retrospectively reviewed the clinical and imaging data from 37 patients with very small ruptured intracranial aneurysms who had SAC using Enterprise stents performed from February 2012 to July 2016 in our department. Data collected and analyzed included patient demographics, morphologic features of the aneurysm, treatment results, and follow-up results. Clinical outcomes were evaluated by the Glasgow Outcome Scale (GOS).Enterprise stents were successfully implanted in all 37 patients with very small ruptured intracranial aneurysms. Of the 37 individuals, 28 patients exhibited complete occlusion at Raymond grade I, 5 patients exhibited occlusion at Raymond grade II, and 4 patients at Raymond grade III. Procedure-related complications occurred in 3 of 37 patients (8.1%), including 1 case of intraprocedure aneurysm rupture who died from cerebral herniation caused by severe postoperative cerebral ischemia during the hospital stay, and the other 2 complications were acute in-stent thrombosis, and occlusion of parent artery caused by falling-off internal carotid artery plaque, respectively. A total of 36 patients underwent postoperative clinical follow-up visits for 6 to 24 months of which 31 patients recovered (GOS ≥ 4). One patient had hemiplegic paralysis, and no rehemorrhage was found. A total of 25 patients underwent follow-up digital subtraction angiography (DSA) at 3-21 months postintervention, in whom there were 22 cases with complete occlusion, 2 cases with recurrence of aneurysm neck, and 1 case with in-stent restenosis, but there was no patient with neurologic deficits.The Enterprise

  8. Application of dual volume reconstruction technique in embolization of intracranial aneurysms

    Directory of Open Access Journals (Sweden)

    Xiang-hai ZHANG

    2014-03-01

    Full Text Available Objective To explore the value of dual volume reconstruction technique in Guglielmi detachable coil (GDC embolization of intracranial aneurysms. Methods Three-dimensional imaging data of 20 patients received GDC embolization of intracranial aneurysms from Jun. 2012 to Apr. 2013 were analyzed for dual volume reconstruction. The value of application of dual volume reconstruction was evaluated by the detection rate of coils bolus, degree of aneurysm occlusion, the length of aneurysm sac and aneurysm neck before and after embolization, and the characteristics and clinical value of the reconstructed images. Results  A total of 20 coil boluses were detected by dual volume reconstruction images, and the detection rate was 100%. Among all of 20 patients, no visualization of contrast medium in the aneurysm was found in 13 patients, while contrast agent was found in the aneurysm sac in 3 patients and in the aneurysm neck in 4 patients. The length of aneurysm neck and sac was somewhat changed before and after embolization with no statistically significant difference (P>0.05. The dual volume reconstruction could reveal coil bolus, vessels, cranium and fusion images, and the aneurysms could be shown by different imaging modes according to the clinical requirement. Conclusion Dual volume reconstruction technique can display the location of coil bolus, degree of occlusion and aneurysm size, and evaluate the embolization effect by multifarious imaging modes, providing a great deal of information for the evaluation of GDC embolization of intracranial aneurysm. DOI: 10.11855/j.issn.0577-7402.2014.02.13

  9. Enterprise stent for waffle-cone stent-assisted coil embolization of large wide-necked arterial bifurcation aneurysms.

    Science.gov (United States)

    Padalino, David J; Singla, Amit; Jacobsen, Walter; Deshaies, Eric M

    2013-01-01

    Large wide-necked arterial bifurcation aneurysms present a unique challenge for endovascular coil embolization treatment. One technique described in the literature deploys a Neuroform stent into the neck of the aneurysm in the shape of a waffle-cone, thereby acting as a scaffold for the coil mass. This case series presents four patients with large wide-necked bifurcation aneurysms treated with the closed-cell Enterprise stent using the waffle-cone technique. Four patients (59 ± 18 years of age) with large wide-necked arterial bifurcation aneurysms (three basilar apex and one MCA bifurcation) were treated with the waffle-cone technique using the Enterprise stent as a supporting device for stent-assisted coil embolization. Three of the patients presented with aneurysmal subarachnoid hemorrhage (Hunt-Hess 2-3; Fisher Grade 3-4). There was no procedural morbidity or mortality associated with treatment itself. One aneurysm was completely obliterated, and three had small residual necks. One patient developed an area of PCA infarct and visual field cut one month after the procedure and required recoiling of the residual neck. The flared ends of the Enterprise stent remodeled the aneurysm neck by conforming to the shape of the neck without any technical difficulty, resulting in a stable scaffold holding the coils into the aneurysm. The closed cell construction, flexibility, and flared ends of the Enterprise stent allow it to conform to the waffle-cone configuration and provide a stable scaffold for coil embolization of large wide-necked arterial bifurcation aneurysms. We have had excellent initial results using the Enterprise stent with the waffle-cone technique. However, this technique is higher risk than standard treatment methods and therefore should be reserved for large wide-necked bifurcation aneurysms where Y stenting is needed, but not possible, and surgical clip ligation is not an option.

  10. Stent-assisted coiling of intracranial aneurysms using LEO stents: long-term follow-up in 153 patients.

    Science.gov (United States)

    Sedat, Jacques; Chau, Yves; Gaudart, Jean; Sachet, Marina; Beuil, Stephanie; Lonjon, Michel

    2018-02-01

    Coiling associated with placement of a self-expandable intracranial stent has improved the treatment of intracranial wide-necked aneurysms. Little is known, however, about the durability of this treatment. The purpose of this report is to present our experience with the LEO stent and to evaluate the complications, effectiveness, and long-term results of this technique. We analyzed the records of 155 intracranial unruptured aneurysms that were treated by stent-assisted coiling with a LEO stent between 2008 and 2012. Procedural, early post-procedural, and delayed complications were recorded. Clinical and angiographic follow-up of patients was conducted over a period of at least 36 months. No procedural mortality was observed. One-month morbidity was observed in 14 out of 153 patients (9,15%). One hundred thirty-eight patients (with 140 aneurysms) had clinical and angiographic follow-up for more than 36 months. No aneurysm rupture was observed during follow-up. Four patients presented an intra-stent stenosis at 8 months, and 6 patients who had an early recurrence were retreated. Final results showed 85% complete occlusion, 13% neck remnants, and 2% stable incomplete occlusion. Stent-assisted coiling with the LEO stent is a safe and effective treatment for unruptured intracranial aneurysms. The long-term clinical outcomes with the LEO stent are excellent with a high rate of complete occlusion that is stable over time.

  11. Direct comparison of Neuroform and Enterprise stents in the treatment of wide-necked intracranial aneurysms

    International Nuclear Information System (INIS)

    Durst, C.R.; Khan, P.; Gaughen, J.; Patrie, J.; Starke, R.M.; Conant, P.; Liu, K.C.; Jensen, M.E.; Evans, A.J.

    2014-01-01

    Aim: To compare the complications and outcomes of Neuroform and Enterprise stents in the treatment of unruptured wide-necked aneurysms. Materials and methods: Under the auspices of the institutional review board, a review of a prospectively collected patient log identified 130 patients who underwent elective stent-assisted coil embolization of a wide-necked aneurysm, including 53 patients treated with an Enterprise stent and 77 patients treated with a Neuroform stent. Immediate and long-term clinical and radiographic outcomes were recorded for all patients. All patient data were handled in accordance with Health Insurance Portability and Accountability Act of 1996 (HIPAA) regulations. Results: The technical success rate was 94%. Overall morbidity was 15% with Enterprise stents and 3% with Neuroform stents (p = 0.020). However, the type of stent used was not predictive of clinical outcomes as measured by the modified Rankin scale. In a multivariate analysis, the use of a Neuroform stent was one of the predictors of retreatment (p = 0.034). Conclusion: Multivariate analyses identified the use of Neuroform stents as an independent predictor of the need for retreatment and the use of Enterprise stents as an independent predictor of morbidity. However, the type of stent was not predictive of clinical outcome as measured by the modified Rankin scale. - Highlights: • The use of Enterprise stents was an independent predictor of morbidity. • The use of Neuroform stents was an independent predictor for retreatment. • The type of stent was not predictive of clinical outcome as measured by the mRS

  12. Crossing Y-stent technique with dual open-cell stents for coiling of wide-necked bifurcation aneurysms.

    Science.gov (United States)

    Ko, Jun Kyeung; Han, In Ho; Cho, Won Ho; Choi, Byung Kwan; Cha, Seung Heon; Choi, Chang Hwa; Lee, Sang Weon; Lee, Tae Hong

    2015-05-01

    Double stenting in a Y-configuration is a promising therapeutic option for wide-necked cerebral aneurysms not amenable to reconstruction with a single stent. We retrospectively evaluated the efficacy and safety of the crossing Y-stent technique for coiling of wide-necked bifurcation aneurysms. By collecting clinical and radiological data we evaluated from January 2007 through December 2013, 20 wide-necked bifurcation aneurysms. Twelve unruptured and eight ruptured aneurysms in 20 patients were treated with crossing Y-stent-assisted coiling. Aneurysm size and neck size ranged from 3.2 to 28.2mm (mean 7.5mm) and from 1.9 to 9.1mm (mean 4.5mm). A Y-configuration was established successfully in all 20 patients. All aneurysms were treated with a pair of Neuroform stents. The immediate angiographic results were total occlusion in 17 aneurysms, residual neck in two, and residual sac in one. Peri-operative morbidity was only 5%. Fifteen of 18 surviving patients underwent follow-up conventional angiography (mean, 10.9 months). The result showed stable occlusion in all 15 aneurysms and asymptomatic in-stent occlusion in one branch artery. At the end of the observation period (mean, 33.5 months), all 12 patients without subarachnoid hemorrhage had excellent clinical outcomes (mRS 0), except one (mRS 2). Of eight patients with subarachnoid hemorrhage, four remained symptom free (mRS 0), while the other four had were dependent or dead (mRS score, 3-6). In this report on 20 patients, crossing Y-stent technique for coiling of wide-necked bifurcation aneurysms showed a good technical safety and favorable clinical and angiographic outcome. Copyright © 2015. Published by Elsevier B.V.

  13. Epidemiology and genetics of intracranial aneurysms

    International Nuclear Information System (INIS)

    Caranci, F.; Briganti, F.; Cirillo, L.; Leonardi, M.; Muto, M.

    2013-01-01

    Intracranial aneurysms are acquired lesions (5–10% of the population), a fraction of which rupture leading to subarachnoid hemorrhage with devastating consequences. Until now, the exact etiology of intracranial aneurysms formation remains unclear. The low incidence of subarachnoid hemorrhage in comparison with the prevalence of unruptured IAs suggests that the vast majority of intracranial aneurysms do not rupture and that identifying those at highest risk is important in defining the optimal management. The most important factors predicting rupture are aneurysm size and site. In addition to ambiental factors (smoking, excessive alcohol consumption and hypertension), epidemiological studies have demonstrated a familiar influence contributing to the pathogenesis of intracranial aneurysms, with increased frequency in first- and second-degree relatives of people with subarachnoid hemorrhage. In comparison to sporadic aneurysms, familial aneurysms tend to be larger, more often located at the middle cerebral artery, and more likely to be multiple. Other than familiar occurrence, there are several heritable conditions associated with intracranial aneurysm formation, including autosomal dominant polycystic kidney disease, neurofibromatosis type I, Marfan syndrome, multiple endocrine neoplasia type I, pseudoxanthoma elasticum, hereditary hemorrhagic telangiectasia, and Ehlers-Danlos syndrome type II and IV. The familial occurrence and the association with heritable conditions indicate that genetic factors may play a role in the development of intracranial aneurysms. Genome-wide linkage studies in families and sib pairs with intracranial aneurysms have identified several loci on chromosomes showing suggestive evidence of linkage, particularly on chromosomes 1p34.3–p36.13, 7q11, 19q13.3, and Xp22. For the loci on 1p34.3–p36.13 and 7q11, a moderate positive association with positional candidate genes has been demonstrated (perlecan gene, elastin gene, collagen type 1 A2

  14. Epidemiology and genetics of intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Caranci, F., E-mail: ferdinandocaranci@libero.it [Unit of Neuroradiology, Department of Diagnostic Radiology and Radiotherapy, Federico II University, Naples (Italy); Briganti, F., E-mail: frabriga@unina.it [Unit of Neuroradiology, Department of Diagnostic Radiology and Radiotherapy, Federico II University, Naples (Italy); Cirillo, L.; Leonardi, M. [Neuroradiology service, Bellaria Hospital, Bologna (Italy); Muto, M., E-mail: mutomar@tiscali.it [Neuroradiology Service Cardarelli Hospital Naples (Italy)

    2013-10-01

    Intracranial aneurysms are acquired lesions (5–10% of the population), a fraction of which rupture leading to subarachnoid hemorrhage with devastating consequences. Until now, the exact etiology of intracranial aneurysms formation remains unclear. The low incidence of subarachnoid hemorrhage in comparison with the prevalence of unruptured IAs suggests that the vast majority of intracranial aneurysms do not rupture and that identifying those at highest risk is important in defining the optimal management. The most important factors predicting rupture are aneurysm size and site. In addition to ambiental factors (smoking, excessive alcohol consumption and hypertension), epidemiological studies have demonstrated a familiar influence contributing to the pathogenesis of intracranial aneurysms, with increased frequency in first- and second-degree relatives of people with subarachnoid hemorrhage. In comparison to sporadic aneurysms, familial aneurysms tend to be larger, more often located at the middle cerebral artery, and more likely to be multiple. Other than familiar occurrence, there are several heritable conditions associated with intracranial aneurysm formation, including autosomal dominant polycystic kidney disease, neurofibromatosis type I, Marfan syndrome, multiple endocrine neoplasia type I, pseudoxanthoma elasticum, hereditary hemorrhagic telangiectasia, and Ehlers-Danlos syndrome type II and IV. The familial occurrence and the association with heritable conditions indicate that genetic factors may play a role in the development of intracranial aneurysms. Genome-wide linkage studies in families and sib pairs with intracranial aneurysms have identified several loci on chromosomes showing suggestive evidence of linkage, particularly on chromosomes 1p34.3–p36.13, 7q11, 19q13.3, and Xp22. For the loci on 1p34.3–p36.13 and 7q11, a moderate positive association with positional candidate genes has been demonstrated (perlecan gene, elastin gene, collagen type 1 A2

  15. A coil placement technique to treat intracranial aneurysm with incorporated artery.

    Science.gov (United States)

    Luo, Chao-Bao; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo

    2018-03-01

    Endovascular coil embolization is an accepted treatment option for intracranial aneurysms. However, the coiling of aneurysms with an incorporated artery (IA) poses a high risk of IA occlusion. Here we report our experience of endovascular coil placement using a technique that avoids IA occlusion in aneurysms with IAs. Over a 6-year period, 185 patients harboring 206 intracranial aneurysms underwent endosaccular coiling. Forty-two of these patients with 45 aneurysms were treated by coil placement to avoid IAs occlusion. We assessed the anatomy of the aneurysms and IAs, technical feasibility of the procedure, and degree of aneurysm occlusion. Clinical and angiographic outcomes were assessed as well. Aneurysms were located in the supra-clinoid intracranial internal carotid artery (n = 24), anterior cerebral artery (n = 6), middle cerebral artery (n = 7), and vertebrobasilar artery (n = 8). The IA was at the aneurysm neck in 34 patients, body in 10, and dome in 1. Immediate post-coiling angiogram showed preservation of blood flow through the IA in all aneurysms. Coil compaction with aneurysmal regrowth was found in 7 of 36 patients having follow-up conventional angiography. One patient had an IA territory infarction after embolization. All 42 patients were followed up (mean: 21 months) and showed no re-bleeding. This technique is effective and safe in managing intracranial aneurysms with IAs. Although aneurysmal recurrence may occur in some aneurysms because of insufficient coiling, this technique is simpler to perform and requires less skill than other techniques. It can be an alternative option for treating some selected intracranial aneurysms with IAs. Copyright © 2017. Published by Elsevier Taiwan LLC.

  16. DSA volumetric 3D reconstructions of intracranial aneurysms: A pictorial essay

    Science.gov (United States)

    Cieściński, Jakub; Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2012-01-01

    Summary A gold standard of cerebral vessel imaging remains the digital subtraction angiography (DSA) performed in three projections. However, in specific clinical cases, many additional projections are required, or a complete visualization of a lesion may even be impossible with 2D angiography. Three-dimensional (3D) reconstructions of rotational angiography were reported to improve the performance of DSA significantly. In this pictorial essay, specific applications of this technique are presented in the management of intracranial aneurysms, including: preoperative aneurysm evaluation, intraoperative imaging, and follow-up. Volumetric reconstructions of 3D DSA are a valuable tool for cerebral vessels imaging. They play a vital role in the assessment of intracranial aneurysms, especially in evaluation of the aneurysm neck and the aneurysm recanalization. PMID:22844309

  17. Endovascular treatment of intracranial aneurysms with bioactive Cerecyte coils: effects on treatment stability

    Energy Technology Data Exchange (ETDEWEB)

    Geyik, Serdar; Yavuz, Kivilcim; Ergun, Onur; Koc, Osman; Cekirge, Saruhan [Hacettepe University Hospitals, Department of Radiology, Ankara (Turkey); Saatci, Isil [Hacettepe University Hospitals, Department of Radiology, Ankara (Turkey); Hacettepe University Hospital, Interventional Neuroradiology Unit, Department of Radiology, Ankara (Turkey)

    2008-09-15

    The Cerecyte coils were developed to improve long-term stability of embolized cerebral aneurysms by producing an increased fibrous reaction over the neck of the aneurysms. We report our preliminary clinical experience with mid-term follow-up. Seventy-eight consecutive patients with 84 intracranial aneurysms treated exclusively with Cerecyte coils were included in this study. Forty-eight aneurysms were ruptured and 36 were incidental. Twenty-two aneurysms were small with (<10 mm) small neck (<4 mm) (SASN); 55 were small with wide neck ({>=}4 mm) (SAWN); six were large (10-25 mm) (L); and one was giant (G) (>25 mm). The embolization technique was the same with that in standard bare coiling. Immediate post-procedure angiography demonstrated complete aneurysm occlusion in 69%, neck remnant in 29.8% and incomplete occlusion in 1.2%. Follow-up angiography was obtained in 80 aneurysms in a period of time ranging from 6 months to 2 years. The overall recanalization rate was 11.3%, and the re-treatment rate was 6.3%; in the subgroup analysis, recanalization rates were 4.5% in S/S; 9.8% in S/W; and 33.3% in large aneurysms. The only giant aneurysm also showed recanalization. Procedure-related morbidity and mortality rates were 2.6% and 1.3%, respectively. Our midterm results showed a relatively low rate of recurrence compared to those reported for platinum coils with morbidity and mortality rates comparable to those with standard bare platinum coils. The efficacy of Cerecyte coils in the long term will be specifically addressed by the ongoing randomized Cerecyte coil trial. (orig.)

  18. Selective embolization of unruptured intracranial aneurysms is associated with low retreatment rate

    Energy Technology Data Exchange (ETDEWEB)

    Bandeira, Alexandra; Raphaeli, Guy [Erasme University Hospital, Department of Radiology, Neuroradiology Section, Brussels (Belgium); Erasme University Hospital, Interventional Neuroradiology Fellows, Brussels (Belgium); Baleriaux, Danielle [Erasme University Hospital, Department of Radiology, Neuroradiology Section, Brussels (Belgium); Bruneau, Michael; Witte, Olivier De [Erasme University Hospital, Neurosurgery, Brussels (Belgium); Lubicz, Boris [Erasme University Hospital, Department of Radiology, Neuroradiology Section, Brussels (Belgium); Hopital Erasme, Service de Radiologie, Brussels (Belgium)

    2010-02-15

    To report long-term imaging findings of 101 patients with 129 unruptured intracranial aneurysms (UIA) treated by embolization. A retrospective review of our prospectively maintained database identified all patients with an UIA treated by embolization with coils only and with a minimal 12-month imaging follow-up. The clinical charts, procedural data, and angiographic results were reviewed. Between March 2004 and June 2009, 101 patients with 129 UIA were identified (71 women/30 men, mean age = 51.4 years). Ninety-four aneurysms (73%) were large (10-25 mm), and 35 (27%) were small (<10 mm). Aneurysms mean size was 10.7 mm (median, 9 mm; range 3-22 mm); 87 UIA (67.5%) had a small neck (<4 mm or neck/sac ratio < 0.7), and 42 (32.5%) had a wide neck ({>=}4 mm or neck/sac ratio {>=} 0.7). Selective coiling with bare/coated coils was performed in 125 cases and four cases, respectively. The balloon-assisted technique was used in 47 cases (36.4%). Only one patient experienced a symptomatic complication (thromboembolism) and kept a slight hemiparesis. Immediate results included 77 complete occlusions (59.7%), 45 neck remnants (34.9%), and 7 incomplete occlusions (5.4%). Mean imaging follow-up of 32 months showed 104 stable occlusions (80.6%), 12 further thrombosis (9.3%), 7 major recanalizations (5.4%), and 6 minor recanalizations (4.7%). Retreatment was required in seven wide-necked and/or large aneurysms including four treated with coated coils. No bleeding occurred during follow-up. Selective embolization of UIA is associated with stable long-term anatomical results and low retreatment rate. (orig.)

  19. Progressive Occlusion of Enterprise Stent-Assisted Coiling of Ruptured Wide-Necked Intracranial Aneurysms and Related Factors on Angiographic Follow-Up: A Single-Center Experience with 468 Patients

    Science.gov (United States)

    Liu, Aihua; Li, Youxiang; Jiang, Chuhan; Wu, Zhongxue

    2014-01-01

    This study was designed to assess the effect of the Enterprise stent on progressive occlusion of wide-necked aneurysms and to evaluate the association between dubious factors and progressive occlusion, which is a consecutive, retrospective, single-center study. Data from 468 patients with 495 wide-necked aneurysms, who had undergone Enterprise stent-assisted coiling (SAC) were reviewed, and the clinical outcomes and the angiographic results were analyzed. A 14-month clinical follow-up was achieved in 421 of the 468 patients (90.0%), showing modified Rankin Scale (mRS) 0–1 in 364 (86.4%), mRS 2 in 17 (4.1%), mRS 3 in 17 (4.1%), mRS 4–5 in 9 (2.1%), and mRS 6 in 14 (3.3%) patients. Overall, the morbidity and mortality were 10.2% and 3.3%, respectively. Initial angiographic results showed Raymond scale (RS)1 in 273 (55.2%), RS2 in 194 (39.2%), and RS3 in 28 (5.6%) patients. Eight-month angiographic follow-up was available in 394 of 495 patients (79.6%), and RS1 was seen in 315 (79.9%), RS2 in 65 (16.5%) and RS3 in 14 (3.6%) cases. At the end of the follow-up, 115 of the 165 (69.7%) patients with initial RS2 and RS3 showed progressive occlusion. Statistical analysis showed no significant difference between progressive occlusion and age (p = 0.654), sex (p = 0.016), aneurysm diameter (p = 0.010), neck size (p = 0.124), dome-to neck ratio (DNR) (p = 0.018) and location (p = 0.001) at the time of follow-up. SAC using Enterprise stent is not only feasible for wide-necked aneurysms, but can achieve a high rate of progressive occlusion with good clinical outcomes at medium-term follow-up. Patient age and aneurysm neck size showed no associated with progressive occlusion at follow-up, while sex, aneurysm diameter, DNR and location were significantly associated with progressive occlusion. PMID:24658387

  20. Y-configuration double-stent-assisted coiling using two closed-cell stents for wide-neck basilar tip aneurysms.

    Science.gov (United States)

    Jeon, Pyoung; Kim, Byung Moon; Kim, Dong Joon; Kim, Dong I K; Park, Keun Young

    2014-09-01

    This study aimed to evaluate clinical and angiographic outcomes of Y-configuration double-stent-assisted (Y-stent) coiling using two closed-cell stents for wide-necked basilar tip aneurysm (BTA). A total of 25 patients underwent Y-stent coiling using two closed-cell stents as a first-time treatment in 18 (3 ruptured) BTAs, retreatment in 2 BTAs and as a third treatment in 5 wide-necked BTAs. Clinical and angiographic outcomes were evaluated retrospectively. Treatment-related complications were three (12.0 %) thromboembolic infarctions due to two acute in-stent thromboses and one embolism. Twenty-two (88 %) patients had favorable outcomes (modified Rankin scale score [mRS], 0-2) during the follow-up period (mean, 30 months; range, 6-54 months). Two patients died: one from initial subarachnoid hemorrhage and the other from intracerebral hemorrhage due to underlying Moyamoya disease. Post-treatment angiograms showed complete occlusion in nine aneurysms, residual neck in 11 aneurysms and residual sac in five aneurysms. Follow-up angiograms were available at least once between 5 to 34 months (mean, 16 months) in 21 patients. Nineteen patients showed improved or stable states (complete occlusion, n = 17; residual neck, n = 2). Major recurrences occurred in two BTAs (9.5 %). Those two major recurrent aneurysms had been large-sized aneurysms at the initial coiling procedure. Both showed not only coil compaction but also progressive growth to giant-sized aneurysms and intra-aneurysmal thrombus formation at the Y-stent coiling as a third-time treatment. Y-stent coiling using two closed-cell stents is a safe and durable treatment option for wide-necked BTA, but may have limited efficacy for large/giant sized and thrombosed aneurysms.

  1. The diagnostic value of three-dimensional dynamic contrast-enhanced MR angiography for intracranial aneurysms

    International Nuclear Information System (INIS)

    Liu Qi; Lu Jianping; Wang Fei; Wang Li; Tian Jianming; Jin Aiguo; Zeng Hao

    2003-01-01

    Objective: To assess the clinical value of three-dimensional dynamic contrast-enhanced MR angiography (3D DCE-MRA) in the detection for intracranial aneurysm. Methods: 3D DCE-MRA was performed in 54 patients highly suspected with intracranial aneurysms. Then conventional digital subtraction angiography (DSA) and feasible endovascular treatment were performed simultaneously. A three-dimensional fast imaging with steady state precession (3D FISP) was used for 3D DCE-MRA(Gd-DTPA dose, 0.2 mmol per kilogram for body weight; acquisition time, 10 seconds). The source images were subtracted from mask images and transferred to computer workstation. All images were subsequently post-processed using three-dimensional reconstruction. 3D DCE-MRA images and DSA images were compared for demonstration of the aneurysm, its neck, and relationship with parent artery, and the usefulness for endovascular treatment was evaluated. Results: There were 39 cases with 45 intracranial aneurysms. The sensitivity, specificity, and accuracy of 3D DCE-MRA were 96%, 73% and 90%, respectively. Aneurysm and its neck depiction at 3D DCE-MRA was significantly better than that at DSA, especially for aneurysms adjacent to the cavernous sinus and near the PICA of vertebral artery. 3D DEC-MRA could guide neurosurgeons to the desired DSA projection, and helped them make plan for interventional or surgical treatment in advance. But the diagnosis should be very carefully made for small aneurysms located in the periphery and the arterial bifurcation. Conclusion: 3D DEC-MRA is a fast, noninvasive and efficient technique for diagnosing intracranial aneurysms. Its three dimensional information is helpful for DSA demonstration and treatment planning. Any uncertain diagnosis requires DSA confirmation

  2. Endovascular treatment of acutely ruptured, wide-necked anterior communicating artery aneurysms using the Enterprise stent.

    Science.gov (United States)

    Huang, Qing-Hai; Wu, Yong-Fa; Shen, Jie; Hong, Bo; Yang, Peng-Fei; Xu, Yi; Zhao, Wen-Yuan; Liu, Jian-Min

    2013-02-01

    The treatment of anterior communicating artery (AcomA) wide-necked aneurysms with the Enterprise stent (Codman, Miami Lakes, FL, USA) has not been commonly described, due to the complexity of the vascular anatomy and the small vessels of the AcomA complex. To evaluate the feasibility, effectiveness and safety of Enterprise stent placement in AcomA aneurysms, we performed this retrospective study. Between November 2008 and December 2010, 27 wide-necked AcomA ruptured aneurysms were treated within 72 hours of ictus with the Enterprise stent. Data collected and analyzed were: demographic data, morphologic features of the aneurysm, treatment results and follow-up results. Twenty-nine Enterprise stents were successfully deployed in all 27 aneurysms, including Y-configuration stent deployment in two patients. The initial embolization degrees were Raymond class I in 20 patients, class II in five and class III in the other two. The angiographic follow-up of 21 patients (mean, 8.4 months) showed that all aneurysms remained stable or improved; there was no in-stent stenosis, recurrence or retreatment. The clinical follow-up of 26 patients (mean, 12.6 months) showed that 23 patients displayed no symptoms and no or mild disability; three patients remained with severe or moderately severe disability. The Enterprise stent is feasible and safe for endovascular embolization of wide-necked AcomA ruptured aneurysms. Further follow up is needed to assess the long-term efficacy of Enterprise stent placement in AcomA. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Predictors of residual flow in embolized intracranial ruptured aneurysms at early follow-up.

    Science.gov (United States)

    Serafin, Zbigniew; Strześniewski, Piotr; Beuth, Wojciech

    2014-01-01

    The possibility of recanalization and the need for retreatment are the most important drawbacks of intracranial aneurysm embolization. The purpose of the study was to prospectively analyze the results of early follow-up angiography of embolized ruptured aneurysms in an attempt to determine factors predicting the presence of residual flow. Evaluation included 72 patients with 72 aneurysms, which were followed-up 3 months after the treatment. Analysis of residual flow predictors included: age and gender, clinical state in Hunt-Hess scale, aneurysm localization, aneurysm three dimensions and volume, neck width, sac-to-neck ratio, initial result of embolization, number of coils used and the use of hydrogel coils and stents. Mean sac diameter was 6.5±3.9 mm, and mean neck width was 2.9±1.4 mm. Follow-up angiography presented residual flow in 26 aneurysms (36.1%): class 2 in 8 aneurysms (11.1%), and class 3 in 18 cases (25.0%). Stable aneurysm filling was observed in 45 cases (62.5%), progression of residual flow in 25 cases (34.7%), and regression in 2 cases (2.8%). According to ROC analysis independent predictors of residual flow were aneurysm neck diameter (AUC 0.857, 95% CI: 0.755-0.928, p<0.0001) and sac-to-neck ratio (AUC 0.817, 95% CI: 0.708-0.898, p<0.0001). Cut-off point of the ROC curve was established at 2.8 mm for neck diameter, and 1.73 for sac-to-neck ratio. Aneurysm neck diameter and sac-to-neck ratio are independently related to the residual flow in embolized ruptured aneurysms at early follow-up.

  4. The Woven EndoBridge (WEB) as primary treatment for unruptured intracranial aneurysms.

    Science.gov (United States)

    van Rooij, Sanne Bt; van Rooij, Willem Jan; Peluso, Jo P; Sluzewski, Menno

    2018-01-01

    Purpose The intrasaccular flow disruptor Woven EndoBridge (WEB) device is developed for the treatment of wide-necked aneurysms without supportive devices. We used the WEB as primary treatment for unruptured aneurysms suitable for the device, regardless of neck size. Methods Between February 2015 and June 2017, 59 aneurysms in 51 patients were selectively treated with the WEB. There were 15 men and 36 women with a mean age of 59 years. Mean aneurysm size was 7.0 mm (range 3-22 mm). Of 59 aneurysms, 45 (76%) had a wide neck defined as ≥4 mm or dome-neck ratio ≤1.5. No stents or supporting balloons were used. Results Initial WEB position was judged good in all 59 unruptured aneurysms. One patient with a basilar tip aneurysm had a late thrombotic posterior cerebral artery occlusion by protrusion of the WEB over the artery. There were no procedural ruptures. Overall complication rate was 2.0% (1 of 51, 95% CI 0.01-11.3%). Imaging follow-up was available in 55 of 59 aneurysms (93%). At 3 months, 41 of 57 aneurysms (72%) were completely occluded, 12 (21%) had a neck remnant and 4 (7%) were incompletely occluded. Conclusion WEB treatment is safe and effective in selected unruptured aneurysms suitable for the device, regardless of neck size or location. There was no need for supportive devices. Three-quarters of all unruptured small aneurysms could be treated with the WEB. In our opinion, the WEB is a valuable alternative to coils, especially in wide-necked aneurysms.

  5. [Congenital anomalies of cerebral artery and intracranial aneurysm].

    Science.gov (United States)

    Nakajima, K; Ito, Z; Hen, R; Uemura, K; Matsuoka, S

    1976-02-01

    It is well known that congenital anomalies such as polycystic kidney, aortic coarctation, Marfan syndrome, Ehler-Danlos syndrome are apt to be complicated by intracranial aneurysms. In this report we attempt to reveal the relation and incidence between cerebrovascular anomalies and intracranial aneurysms. The etiology of aneurysms has been discussed, too. 12 cases of persistent trigeminl artery, 2 cases of persistent hypoglossal artery and 11 cases of fenestration were obtained from 3841 patients who were angiographically examined in our clinic for 5 years. The incidence is 0.31%, 0.05% and 0.29%, respectively. Persistent trigeminal arteries were complicated by 2 cases of intracranial aneurysms and one case of arterivenous malformations (AVM), persistent hypoglossal arteries were complicated by one case of aneurysm, and fenestrations were complicated by 2 cases of aneurysms and one case of AVM. One case of congenital agenesis of right internal carotid artery was obtained which was complicated by aneurysm of anterior communicating artery. Totally, 8 cases of aneurysms and AVM were obtained from 26 cases of cerebrovascular anomalies (incidence 30.8%). On the other hand, thalamic or caudate hemorrhage revealed the highest incidence of complication of intracranial aneurysms among intracerebral hematomas (10.7%). Compared with the incidence of aneurysms between cerebro vascular anomalies (30.8%) and thalamic or caudate hemorrhage (10.7%), the difference is statistically signigicant (P less than 0.05). The cause of intracranial aneurysm has not yet been clarified. But it is well accepted that the defect of tunica media vasorum is most responsible factor as to the occurrence of intracranial aneurysms. We concluded that the genetic error of cerebral vessels including defect of media caused intracranial aneurysms, and this result was supported from the evidence that cerebrovascular anomalies showed statistically high incidence of complication of intracranial aneurysms.

  6. Treatment of Wide-Neck Bifurcation Aneurysm Using "WEB Device Waffle Cone Technique".

    Science.gov (United States)

    Mihalea, Cristian; Caroff, Jildaz; Rouchaud, Aymeric; Pescariu, Sorin; Moret, Jacques; Spelle, Laurent

    2018-05-01

    The endovascular treatment of wide-neck bifurcation aneurysms can be challenging and often requires the use of adjunctive techniques and devices. We report our first experience of using a waffle-cone technique adapted to the Woven Endoluminal Bridge (WEB) device in a large-neck basilar tip aneurysm, suitable in cases where the use of Y stenting or other techniques is limited due to anatomic restrictions. The procedure was complete, and angiographic occlusion of the aneurysm was achieved 24 hours post treatment, as confirmed by digital subtraction angiography. No complications occurred. The case reported here was not suitable for Y stenting or deployment of the WEB device alone, due to the small caliber of both posterior cerebral arteries and their origin at the neck level. The main advantage of this technique is that both devices have a controlled detachment system and are fully independent. To our knowledge, this technique has not been reported previously and this modality of treatment has never been described in the literature. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Relationship between Angiographic Results and Morphology in Sidewall Intracranial Aneurysms after Stent-Assisted Coil Embolization.

    Science.gov (United States)

    Nii, Kouhei; Aikawa, Hiroshi; Tsutsumi, Masanori; Eto, Ayumu; Iko, Minoru; Sakamoto, Kimiya; Inoue, Ritsuro; Mitsutake, Takafumi; Hanada, Hayatsura; Kazekawa, Kiyoshi

    2016-03-01

    Stent-assisted coil embolization (SACE) is used to address wide-necked or complex aneurysms. However, as they may recanalize after SACE, predictors of recanalization are needed. We investigated the relationship between follow-up angiographic results and the morphology of sidewall (SW) aneurysms in patients treated by SACE. Between September 2010 and September 2014, we performed 80 SACE procedures for SW intracranial aneurysms. Angiographic findings, obtained immediately after the procedure, 3-6 months thereafter, and when aneurysmal recanalization was suspected on MR angiogram scan, were recorded. Morphologically, the SW aneurysms were classified as "outside" (OS) and "partially inside" (PI) based on the curve of the axes of the proximal or distal parent artery with respect to the aneurysmal neck. Follow-up angiographic studies on OS- and PI SW aneurysms were compared. On the initial angiograms, we classified 42 aneurysms as OS and 38 as PI. Immediately after SACE, there was no significant difference in the angiographic findings on OS and PI aneurysms. However, on follow-up angiograms, there was a significant difference in the rate of spontaneous improvement (4 of 42 [OS] versus 21 of 38 [PI], P = .001). We performed additional coil embolization to treat 3 recanalized OS aneurysms. SW aneurysms classified morphologically as PI tended to occlude progressively even after incomplete occlusion by SACE. In contrast, aneurysms classified as OS must be observed carefully after SACE. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  8. Pulsatile flow effects on the hemodynamics of intracranial aneurysms.

    Science.gov (United States)

    Le, Trung B; Borazjani, Iman; Sotiropoulos, Fotis

    2010-11-01

    High-resolution numerical simulations are carried out to systematically investigate the effect of the incoming flow waveform on the hemodynamics and wall shear stress patterns of an anatomic sidewall intracranial aneurysm model. Various wave forms are constructed by appropriately scaling a typical human waveform such that the waveform maximum and time-averaged Reynolds numbers, the Womersley number (α), and the pulsatility index (PI) are systematically varied within the human physiologic range. We show that the waveform PI is the key parameter that governs the vortex dynamics across the aneurysm neck and the flow patterns within the dome. At low PI, the flow in the dome is similar to a driven cavity flow and is characterized by a quasi-stationary shear layer that delineates the parent artery flow from the recirculating flow within the dome. At high PI, on the other hand, the flow is dominated by vortex ring formation, transport across the neck, and impingement and breakdown at the distal wall of the aneurysm dome. We further show that the spatial and temporal characteristics of the wall shear stress field on the aneurysm dome are strongly correlated with the vortex dynamics across the neck. We finally argue that the ratio between the characteristic time scale of transport by the mean flow across the neck and the time scale of vortex ring formation can be used to predict for a given sidewall aneurysm model the critical value of the waveform PI for which the hemodynamics will transition from the cavity mode to the vortex ring mode.

  9. Treatment of intracranial aneurysms by flow diverter devices: Long-term results from a single center

    Energy Technology Data Exchange (ETDEWEB)

    Briganti, Francesco, E-mail: frabriga@unina.it [Unit of Interventional Neuroradiology, Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Napoli, Manuela, E-mail: napoli.manuela@gmail.com [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Leone, Giuseppe, E-mail: g.leonemd@gmail.com [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Marseglia, Mariano, E-mail: mariano-marseglia@libero.it [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Mariniello, Giuseppe, E-mail: giuseppe.mariniello@unina.it [Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Caranci, Ferdinando, E-mail: ferdinando.caranci@unina.it [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Tortora, Fabio, E-mail: fabiotor@libero.it [Chair of Neuroradiology, “Magrassi Lanzara” Clinical-Surgical Department, Second University of Naples, Viale Colli Aminei 21, 80131 Naples (Italy); Maiuri, Francesco, E-mail: frmaiuri@unina.it [Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy)

    2014-09-15

    Highlights: • We report the long-term results (2–4 years) with Flow Diverter Devices (FDD) from a single-center. • We recommend the use of FDD for large-neck aneurysms of the ICA syphon. • We think that more sophisticate FDD will reduce the incidence of technical adverse events. - Abstract: Objectives: Flow-Diverter Devices (FDD) are a new generation stents designed for the treatment of the intracranial aneurysms. This article reports the long-term results (2–4 years) of this treatment from a single-center. Methods: From November 2008 to January 2012, 35 patients (29 females and 6 males; mean age 53.9 y) with 39 intracranial aneurysms were treated by FDD. Five patients (14.3%) had ruptured aneurysms and 30 (85.7%) had no previous hemorrhage. The procedures were performed in 5 patients (14.3%) with SILK and in 30 (85.7%) with PED. In 3 patients FDDs were used as a second treatment after failure of previous coiling (2 cases) or stenting (one case). The 39 aneurysms were in supraclinoid ICA in 26 (66.7%), cavernous ICA in 2 (5.1%), PCoA in 4 (10.2%), MCA in 5 (12.9%), SCA in 1 (2.6%) and PICA in 1 (2.6%). The aneurysms were small (<10 mm) in 32 cases (82%), large (11–25 mm) in 6 (15.3%) and giant in 1 (2.6%). The occlusion rate according to the aneurysm location, size and neck and the complications were evaluated. Results: Peri-procedural complications included transient dysarthria (2 patients), vasospasm with acute intra-stent aggregation (one), microwire rupture (one) and failure of the stent opening (one). The follow-up was made between 24 and 62 months (mean 41 months); clinical examination and CTA were performed at 1, 3, 6 and 12 months after the procedure. The complete occlusion was confirmed by CTA and DSA. MRI with angiographic-studies was taken every year. Complete occlusion was obtained in 35 aneurysms (92.1%) and subtotal in 3 (7.9%). Complete occlusion occurred at 3 months in 24 cases (68.6%), within 3 and 6 months in 9 (25.7%). The rate and

  10. Treatment of intracranial aneurysms by flow diverter devices: Long-term results from a single center

    International Nuclear Information System (INIS)

    Briganti, Francesco; Napoli, Manuela; Leone, Giuseppe; Marseglia, Mariano; Mariniello, Giuseppe; Caranci, Ferdinando; Tortora, Fabio; Maiuri, Francesco

    2014-01-01

    Highlights: • We report the long-term results (2–4 years) with Flow Diverter Devices (FDD) from a single-center. • We recommend the use of FDD for large-neck aneurysms of the ICA syphon. • We think that more sophisticate FDD will reduce the incidence of technical adverse events. - Abstract: Objectives: Flow-Diverter Devices (FDD) are a new generation stents designed for the treatment of the intracranial aneurysms. This article reports the long-term results (2–4 years) of this treatment from a single-center. Methods: From November 2008 to January 2012, 35 patients (29 females and 6 males; mean age 53.9 y) with 39 intracranial aneurysms were treated by FDD. Five patients (14.3%) had ruptured aneurysms and 30 (85.7%) had no previous hemorrhage. The procedures were performed in 5 patients (14.3%) with SILK and in 30 (85.7%) with PED. In 3 patients FDDs were used as a second treatment after failure of previous coiling (2 cases) or stenting (one case). The 39 aneurysms were in supraclinoid ICA in 26 (66.7%), cavernous ICA in 2 (5.1%), PCoA in 4 (10.2%), MCA in 5 (12.9%), SCA in 1 (2.6%) and PICA in 1 (2.6%). The aneurysms were small (<10 mm) in 32 cases (82%), large (11–25 mm) in 6 (15.3%) and giant in 1 (2.6%). The occlusion rate according to the aneurysm location, size and neck and the complications were evaluated. Results: Peri-procedural complications included transient dysarthria (2 patients), vasospasm with acute intra-stent aggregation (one), microwire rupture (one) and failure of the stent opening (one). The follow-up was made between 24 and 62 months (mean 41 months); clinical examination and CTA were performed at 1, 3, 6 and 12 months after the procedure. The complete occlusion was confirmed by CTA and DSA. MRI with angiographic-studies was taken every year. Complete occlusion was obtained in 35 aneurysms (92.1%) and subtotal in 3 (7.9%). Complete occlusion occurred at 3 months in 24 cases (68.6%), within 3 and 6 months in 9 (25.7%). The rate and

  11. Comparison of Enterprise with Neuroform stent-assisted coiling of intracranial aneurysms.

    Science.gov (United States)

    Kadkhodayan, Yasha; Rhodes, Nicholas; Blackburn, Spiros; Derdeyn, Colin P; Cross, DeWitte T; Moran, Christopher J

    2013-04-01

    The Enterprise stent is the first closed-cell stent designed to treat wide-necked intracranial aneurysms. Advantages of the design can include improvement in keeping coils within an aneurysm and the ability of the stent to be recaptured. We compared the technical and clinical complications of the Enterprise stent with the open-cell Neuroform stent, its primary alternative. Patients undergoing Enterprise and Neuroform stent-assisted aneurysm coiling were enrolled in prospective registries starting in March 2007 and February 2003, respectively. All consecutive patients through December 2011 were included. Deployment success and difficulty, stent movement and misplacement, and procedural complications were compared. Enterprise deployment success was high (108 of 115 attempts, 93.9%) with 102 aneurysms receiving a stent compared with Neuroform (173 of 214 attempts, 80.8%, p = 0.001) with 163 aneurysms. Enterprise was easier to deploy (1.7% vs 15.9% difficult deployment, p Enterprise stent (8.7% vs 1.4%, p = 0.0021). The Enterprise stent enabled treatment of 10 additional aneurysms that could not be treated with Neuroform and had a higher rate of immediate aneurysm occlusion (87.3% vs 73.0%, p = 0.0058). Enterprise was easier to deploy and enabled treatment of additional aneurysms; however, there were more thromboembolic complications. On the basis of these findings, we prefer to use the Neuroform stent first and rely on the Enterprise stent as an easy-to-deliver backup for stent-assisted coiling.

  12. The use of novel flow diverting device Tubridge for the treatment of intracranial aneurysms: initial experience

    International Nuclear Information System (INIS)

    Yang Pengfei; Liu Jianmin; Huang Qinghai; Xu Yi; Hong Bo; Zhao Wenyuan; Li Qiang; Fang Yibin; Zhang Yuhui

    2011-01-01

    Objective: To preliminarily evaluate the feasibility, efficacy and safety of the novel flow diverting device, Tubridge, in treating intracranial aneurysms. Methods: The novel flow diverting device, Tubridge, was employed to treat intracranial aneurysms in 14 patients with a mean age of (52.4±10.2) years. A total of 14 intracranial aneurysms were detected in 14 patients, including 13 un-ruptured aneurysms and one ruptured aneurysms. The technical results and clinical data were analyzed. Results: A total of 18 flow diverters were implanted. The flow diverter was successfully conveyed and delivered in all patients, with a technical success rate of 100%. Six aneurysms were treated with the flow diverter together with the coils. Of the six aneurysms, complete obliteration of the aneurysm was obtained in 2 (Raymond grade Ⅰ), remnant of neck was seen in 1 (Raymond grade Ⅱ) and residual aneurysm sac was found in 3 (Raymond grade Ⅲ) cases. Eight aneurysms were treated with flow diverter implantation alone. After the procedure, marked decrease in contrast filling of the aneurysm sac was seen in 3 aneurysms, while the change in contrast filling pattern of the aneurysm sac as well as the obvious retention of contrast in the aneurysm sac could be detected in all cases. No procedure-related hemorrhagic or ischemic complications occurred. The mRS score at the time of discharge was 0 (n=13) or 1 (n=1). Conclusion: For the treatment of some special type intracranial aneurysms, the use of Tubridge flow diverter is clinically feasible, its effect is immediate and satisfactory with higher safety in short term. However, its long-term efficacy and safety need to be further evaluated. (authors)

  13. CT during selective arteriography: anatomical assessment of unruptured intracranial aneurysms before endovascular treatment

    International Nuclear Information System (INIS)

    Nomura, M.; Kida, S.; Uchiyama, N.; Yamashima, T.; Yamashita, J.; Sanada, J.; Yoshikawa, J.; Matsui, O.

    2001-01-01

    Our aim was to investigate the usefulness of helical CT during selective angiography (CT arteriography) in pretreatment assessment of unruptured intracranial aneurysms. We studied 47 unruptured aneurysms in 34 prospectively recruited patients for whom endovascular embolisation was initially considered. As pretreatment assessment, we performed rotational digital subtraction angiography (DSA) followed by CT arteriography. The findings on axial source images (axial images) and reconstructed three-dimensional CT angiography (3D-CTA) of CT arteriography were compared to those of rotational DSA, with particular attention to the neck of the aneurysm and arterial branches adjacent to it. Information provided by CT arteriography was more useful than that of rotational DSA as regards the neck in 25 (53 %) of 47 cases and as regards branches in 18 (49 %) of 37 aneurysms. On axial images, small arteries such as the anterior choroidal artery were seen in some cases. CT arteriography can provide valuable additional information about unruptured aneurysms, which cannot be obtained by rotational DSA alone. This technique is useful for obtaining anatomical information about aneurysm anatomy and for deciding the therapeutic strategy. (orig.)

  14. Safety and efficacy of aneurysm treatment with WEB

    DEFF Research Database (Denmark)

    Pierot, Laurent; Costalat, Vincent; Moret, Jacques

    2016-01-01

    OBJECT WEB is an innovative intrasaccular treatment for intracranial aneurysms. Preliminary series have shown good safety and efficacy. The WEB Clinical Assessment of Intrasaccular Aneurysm Therapy (WEBCAST) trial is a prospective European trial evaluating the safety and efficacy of WEB in wide......-neck bifurcation aneurysms. METHODS Patients with wide-neck bifurcation aneurysms for which WEB treatment was indicated were included in this multicentergood clinical practices study. Clinical data including adverse events and clinical status at 1 and 6 months were collected and independently analyzed by a medical....... RESULTS Ten European neurointerventional centers enrolled 51 patients with 51 aneurysms. Treatment with WEB was achieved in 48 of 51 aneurysms (94.1%). Adjunctive implants (coils/stents) were used in 4 of 48 aneurysms (8.3%). Thromboembolic events were observed in 9 of 51 patients (17.6%), resulting...

  15. The risk of intravenous thrombolysis-induced intracranial hemorrhage in Taiwanese patients with unruptured intracranial aneurysm.

    Directory of Open Access Journals (Sweden)

    Wei Ting Chiu

    Full Text Available The presence of an intracranial aneurysm is contraindicated to recombinant tissue plasminogen activator (r-tPA treatment for acute ischemic stroke. However, it is difficult to exclude asymptomatic intracranial aneurysms by using conventional, noncontrast head computed tomography (CT, which is the only neuroimaging suggested before r-tPA. Recent case reports and series have shown that administering r-tPA to patients with a pre-existing aneurysm does not increase the bleeding risk. However, Asians are known to have a relatively higher bleeding risk, and little evidence is available regarding the risk of using r-tPA on Asian patients with intracranial aneurysms.Medical records from the Shuang Ho hospital stroke registration between July 2010 and December 2014 were retrospectively reviewed, and 144 patients received r-tPA. Unruptured intracranial aneurysms were detected using CT, or magnetic resonance or conventional angiography after r-tPA. The primary and secondary outcomes were the difference in overall intracranial hemorrhage (ICH and symptomatic ICH after r-tPA. The differences were analyzed using Fisher's exact or Mann-Whitney U tests, and p < 0.05 was defined as the statistical significance.A total of 144 patients were reviewed, and incidental unruptured intracranial aneurysms were found in 11 of them (7.6%. No significant difference was observed in baseline demographic data between the aneurysm and nonaneurysm groups. Among patients with an unruptured aneurysm, two had giant aneurysms (7.7 and 7.4 mm, respectively. The bleeding risk was not significant different between aneurysm group (2 out of 11, 18% with nonaneurysm group (7 out of 133, 5.3% (p = 0.14. None of the patients with an unruptured aneurysm had symptomatic ICH, whereas one patient without an aneurysm exhibited symptomatic ICH.The presence of an unruptured intracranial aneurysm did not significantly increase the risk of overall and symptomatic ICH in Taiwanese patients after they

  16. Comparison of 3D TOF-MRA and 3D CE-MRA at 3 T for imaging of intracranial aneurysms

    International Nuclear Information System (INIS)

    Cirillo, Mario; Scomazzoni, Francesco; Cirillo, Luigi; Cadioli, Marcello; Simionato, Franco; Iadanza, Antonella; Kirchin, Miles; Righi, Claudio; Anzalone, Nicoletta

    2013-01-01

    Purpose: To compare 3 T elliptical-centric CE MRA with 3 T TOF MRA for the detection and characterization of unruptured intracranial aneurysms (UIAs), by using digital subtracted angiography (DSA) as reference. Materials and methods: Twenty-nine patients (12 male, 17 female; mean age: 62 years) with 41 aneurysms (34 saccular, 7 fusiform; mean diameter: 8.85 mm [range 2.0–26.4 mm]) were evaluated with MRA at 3 T each underwent 3D TOF-MRA examination without contrast and then a 3D contrast-enhanced (CE-MRA) examination with 0.1 mmol/kg bodyweight gadobenate dimeglumine and k-space elliptic mapping (Contrast ENhanced Timing Robust Angiography [CENTRA]). Both TOF and CE-MRA images were used to evaluate morphologic features that impact the risk of rupture and the selection of a treatment. Almost half (20/41) of UIAs were located in the internal carotid artery, 7 in the anterior communicating artery, 9 in the middle cerebral artery and 4 in the vertebro-basilar arterial system. All patients also underwent DSA before or after the MR examination. Results: The CE-MRA results were in all cases consistent with the DSA dataset. No differences were noted between 3D TOF-MRA and CE-MRA concerning the detection and location of the 41 aneurysms or visualization of the parental artery. Differences were apparent concerning the visualization of morphologic features, especially for large aneurysms (>13 mm). An irregular sac shape was demonstrated for 21 aneurysms on CE-MRA but only 13/21 aneurysms on 3D TOF-MRA. Likewise, CE-MRA permitted visualization of an aneurismal neck and calculation of the sac/neck ratio for all 34 aneurysms with a neck demonstrated at DSA. Conversely, a neck was visible for only 24/34 aneurysms at 3D TOF-MRA. 3D CE-MRA detected 15 aneurysms with branches originating from the sac and/or neck, whereas branches were recognized in only 12/15 aneurysms at 3D TOF-MRA. Conclusion: For evaluation of intracranial aneurysms at 3 T, 3D CE-MRA is superior to 3D TOF

  17. Diagnosis of ruptured intracranial aneurysm in acute stage

    International Nuclear Information System (INIS)

    Yoshiyama, Masataka; Nakagawa, Toshifumi

    1980-01-01

    Subarachnoid hemorrhage at an acute stage within one day from the onset to the first CT scan was classified into subarachnoid hemorrhage secondary to intracranial aneurysm, subarachnoid hemorrhage of unknown origin and subarachnoid hemorrhage of which angiography could not be carried out, and the first CT findings, the severity, and the prognosis of these subarachnoid hemorrhage were compared and discussed. CT findings of subarachnoid hemorrhage secondary to intracranial aneurysm showed various changes according to progress in the severity with time, and intracranial hematoma, intraventricular clots and ventricular dilatation increased according to progress in the severity. Ruptured intracranial aneurysm in middle cerebral artery, anterior cerebral artery and anterior communicating artery could be found easily by CT, but that in internal carotid artery and vertabral basilar artery was difficult to be detected by CT. When cerebral angiography was carried out repeatedly for ruptured intracranial aneurysm of unknown origin, the time of performance must be consifered with attention to angiospasms or hematoma. (Tsunoda, M.)

  18. Endovascular treatment for pediatric intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Xianli; Jiang, Chuhan; Li, Youxiang; Yang, Xinjian; Wu, Zhongxue [Capital Medical University, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Beijing, Hebei (China)

    2009-11-15

    The purpose of this study is to report the characteristics and outcomes of pediatric patients with intracranial aneurysms. From 1998 to 2005, 25 pediatric patients (aged {<=}17 years) with intracranial aneurysm were treated at our institute. Eleven of 25 patients had subarachnoid hemorrhage. In ten patients, the aneurysm was an incidental finding. One patient presented with cranial nerves dysfunction and three with neurological deficits. The locations of the aneurysms were as follows: vertebral artery (VA; n = 9), middle cerebral artery (MCA; n = 5), posterior cerebral artery (PCA; n = 4), basilar artery (BA; n = 2), anterior communicating artery (n = 2), anterior cerebral artery (n = 2), and internal carotid artery (n = 1). Five patients were treated with selective embolization with coils. Sixteen patients were treated with parent vessel occlusion (PVO). Eight PVOs were performed with balloons and eight were performed with coils. One patient with a VA aneurysm was spontaneously thrombosed 4 days after the initial diagnostic angiogram. In three patients treated with stent alone or stent-assisted coiling, one with BA trunk aneurysm died. One aneurismal recurrence occurred and was retreated. At a mean follow-up duration of 23.5 months, 96% of patients had a Glasgow Outcome Scale score of 4 or 5. Pediatric intracranial aneurysms occur more commonly in male patients and have a predilection for the VA, PCA, and MCA. PVO is an effective and safe treatment for fusiform aneurysms. Basilar trunk fusiform aneurysms were difficult to treat and were associated with a high mortality rate. (orig.)

  19. Abciximab for thrombolysis during intracranial aneurysm coiling

    International Nuclear Information System (INIS)

    Gralla, Jan; Rennie, Adam T.M.; Corkill, Rufus A.; Lalloo, Shivendra T.; Molyneux, Andrew; Byrne, James V.; Kuker, Wilhem

    2008-01-01

    Thrombotic events are a common and severe complication of endovascular aneurysm treatment with significant impact on patients' outcome. This study evaluates risk factors for thrombus formation and assesses the efficacy and safety of abciximab for clot dissolution. All patients treated with abciximab during (41 patients) or shortly after (22 patients) intracranial aneurysm coil embolisation were retrieved from the institutional database (2000 to 2007, 1,250 patients). Sixty-three patients (mean age, 55.3 years, ±12.8) had received either intra-arterial or intravenous abciximab. Risk factors for clot formation were assessed and the angiographic and clinical outcome evaluated. No aneurysm rupture occurred during or after abciximab application. The intra-procedural rate of total recanalisation was 68.3%. Thromboembolic complications were frequently found in aneurysms of the Acom complex and of the basilar artery, whilst internal carotid artery aneurysms were underrepresented. Two patients died of treatment-related intracranial haemorrhages into preexisting cerebral infarcts. Two patients developed a symptomatic groin haematoma. Abciximab is efficacious and safe for thrombolysis during and after endovascular intracranial aneurysm treatment in the absence of preexisting ischaemic stroke. (orig.)

  20. Middle and long-term follow-up of intracranial aneurysms treated with Matrix detachable coils

    International Nuclear Information System (INIS)

    Wu Xi; Liu Jianmin; Huang Qinghai; Xu Yi

    2008-01-01

    Objective: This study was undertaken to evaluate the safety of the polyglycolic/polylactic acid (PGLA)-coated Matrix detachable coils (Matrix) and analyze factors which may relate to the recanalization rate of the Matrix coils in the treatment of intracranial aneurysms. Methods: 75 patients underwent 79 aneurysm treatments with Matrix coils from May 2003 to July 2005 were retrospectively investigated. Morphological changes were compared postoperatively with last-follow-up digital subtraction angiography (DSA) by using the Raymond scale. We defined incomplete recanalization or stable aneurysms as uncured, while those of progressive occlusion or complete occlusion aneurysms demonstrated on the last-follow-up imagings as cured. We also utilized Cox model for analyzing the relationships between factors including age, gender, degree of aneurysmal occlusion, stenting, aneurysm neck size, aneurysm maximum size and Matrix coils length (%) and the long-term angiographic follow-up results. Results: The correlative surgical complications rate with Matrix coils was 13.3%. The total rate of recanalization was 11.4%. Large aneurysms treated with combined stenting got 40% recanalization. No statistic relationships were shown between the factors forementioned and the recanalization rate, but progressive occlusion was observed in 11 (61%)incompletely treated aneurysms. Conclusions: Matrix detachable coil technique is safe for intracranial aneurysm and would further decrease the recurrence of large aneurysm with combination of stenting but long term efficacy needs further follow-up and large scale randomized control study. (authors)

  1. 3D angiography in the evaluation of intracranial aneurysms before and after treatment. Initial experience

    International Nuclear Information System (INIS)

    Lauriola, Walter; Nardella, Michele; Strizzi, Vincenzo; Florio, Francesco; Cali, Alessandro; D'Angelo, Vincenzo

    2005-01-01

    Purpose: The aim of the study is to evaluate the advantages of 3D angiography as compared to 2D angiography in assessing intracranial aneurysms before and after treatment and, in particular, in selecting and planning the correct treatment. Materials and methods: Thirty intracranial aneurysms were retrospectively reviewed before and after treatment. The study population consisted of 12 men and 18 women (age range: 35-77 years; mean age: 58 years). Eighteen aneurysms were treated surgically, 10 endovascularly and 2 with combined treatment. The 2D and 3D finding before and after the treatment were compared , and the pre-treatment angiographic images were compared with surgical findings. The following parameters were assessed and compared: aneurysmal sac and neck size, vascular involvement and evaluation of post-treatment residual mass. Results: On the 2D DSA images, visualisation of the sac and neck was optimal in 45% and 15% of cases, adequate in 10% and 35% of cases and inadequate in 5% and 50% of cases, respectively. On the 3D DSA images, visualisation of the sac and neck was optimal in 100% of cases. Three-dimensional DSA was able to detect 8 aneurysms with vessel involvement in all cases (100%). Of these, four (50%) went undetected on 2D DSA; in two cases, two-dimensional DSA erroneously detected the presence of vascular involvement (false positive). Three-dimensional angiography proved superior to 2D angiography in the evaluation of the residual aneurysms treated with clipping. Finally, 3D DSA was able to reduce the number of the radiographic projections, the quantity of contrast medium, the time and associated risks necessary for a precise evaluation of the aneurysm. Conclusions: In our first experience, 3D DSA proved useful in reducing the risks and diagnostic time as well as in selecting and planning the treatment. Moreover, it improved the operating conditions of both surgical and endovascular treatment. Technological advances in this field will enable the

  2. Individualized management for intracranial vertebral artery dissecting aneurysms

    Directory of Open Access Journals (Sweden)

    SHANG Yan-guo

    2012-02-01

    Full Text Available Objective To discuss the individualized management strategy for intracranial vertebral artery dissecting aneurysms. Methods Eighteen patients with intracranial vertebral artery dissecting aneurysms were treated with different surgical methods. Results Eighteen patients underwent different surgical treatment. Five patients underwent complete occlusion of the aneurysm and parent artery by coiling, 5 were treated by stent -assisted coiling (3 densely packed coiling and 2 non-densely packed coiling, 4 underwent stent-only therapy and 3 of them presented hemodynamic improvement after surgery, 3 were treated by direct surgical clipping, and 1 underwent occipital artery-posterior inferior cerebellar artery bypass. Two aneurysms ruptured immaturely, in which one patient died on the third day after operation and one patient occurred moderate disablity. Only 1 patient who underwent complete occlusion of aneurysm and parent artery presented temporarily ischemic symptoms. No adverse effects were seen in other patients. Seventeen patients were followed up for 1 month to 3 years, and all the aneurysms were stable. Conclusion There are many kinds of therapeutic methods for intracranial vertebral artery dissecting aneurysms. The patients should be treated according to several factors such as the clinical manifestations, aneurysm configuration, and relationship with the posterior inferior cerebellar artery. The treatment should be individualized.

  3. Spiral CT angiography and surgical correlations in the evaluation of intracranial aneurysms

    International Nuclear Information System (INIS)

    Preda, L.; Di Maggio, E.M.; La Fianza, A.; Dore, R.; Fulle, I.; Solcia, M.; Campani, R.; Gaetani, P.; Rodriguez y Baena, R.; Cecchini, A.; Infuso, L.

    1998-01-01

    We investigated the accuracy of spiral computed tomography angiography (CTA) in the detection and study of intracranial aneurysms by comparing CTA with selective angiograms and surgical findings. Twenty-six patients (9 men and 17 women; mean age 53.1 ± 1.8 years) with suspected intracranial aneurysms were submitted to CTA (1- to 2-mm slices, pitch 1:1, 24 s, RI = 1) after a conventional CT examination showing subarachnoid hemorrhage (SAH) in 19 cases and during neuroradiological investigations performed for other reasons in 7 cases. One hundred twenty to 150 ml iodate contrast agent (0.3-0.4 gI/ml) were injected intravenously at 5 ml/s rate and with 12- to 25-s delay calculated with a preliminary test bolus. Three-dimensional shaded surface display (3D SSD) and maximum intensity projection (MIP) reconstructions were obtained from axial images. Then, within 48 h, all patients were submitted to digital subtraction angiography (DSA), with separate assessment of CTA and DSA findings. Twenty-two aneurysms shown by CTA were confirmed at DSA and surgery (true positives), whereas the vascular lesion was not confirmed at DSA in 2 cases (false positives). The presence of intracranial aneurysms was excluded at both CTA and subsequent DSA in 7 cases (true negatives) and there were no false negatives; sensitivity was 100 %, specificity 77.8 %, and diagnostic accuracy 93.5 %. Computed tomography angiography aneurysm location was confirmed at surgery in all cases, with very high accuracy in assessing the presence of an aneurysm neck (100 %). Computed tomography angiography accurately depicted the aneurysm shape in 20 of 22 cases, but failed to depict its multilobed nature in 2 cases. The mean aneurysm diameter calculated at CTA was 0.99 ± 0.12 cm vs 1.09 ± 0.11 cm at surgery (p < 0.01). The present results suggest that the high sensitivity of CTA, if confirmed by further studies, might help in avoiding having to resort to arteriography after negative CTA in SAH patients. (orig.)

  4. Intracranial Aneurysms of Neuro-Ophthalmologic Relevance.

    Science.gov (United States)

    Micieli, Jonathan A; Newman, Nancy J; Barrow, Daniel L; Biousse, Valérie

    2017-12-01

    Intracranial saccular aneurysms are acquired lesions that often present with neuro-ophthalmologic symptoms and signs. Recent advances in neurosurgical techniques, endovascular treatments, and neurocritical care have improved the optimal management of symptomatic unruptured aneurysms, but whether the chosen treatment has an impact on neuro-ophthalmologic outcomes remains debated. A review of the literature focused on neuro-ophthalmic manifestations and treatment of intracranial aneurysms with specific relevance to neuro-ophthalmologic outcomes was conducted using Ovid MEDLINE and EMBASE databases. Cavernous sinus aneurysms were not included in this review. Surgical clipping vs endovascular coiling for aneurysms causing third nerve palsies was compared in 13 retrospective studies representing 447 patients. Complete recovery was achieved in 78% of surgical patients compared with 44% of patients treated with endovascular coiling. However, the complication rate, hospital costs, and days spent in intensive care were reported as higher in surgically treated patients. Retrospective reviews of surgical clipping and endovascular coiling for all ocular motor nerve palsies (third, fourth, or sixth cranial nerves) revealed similar results of complete resolution in 76% and 49%, respectively. Improvement in visual deficits related to aneurysmal compression of the anterior visual pathways was also better among patients treated with clipping than with coiling. The time to treatment from onset of visual symptoms was a predictive factor of visual recovery in several studies. Few reports have specifically assessed the improvement of visual deficits after treatment with flow diverters. Decisions regarding the choice of therapy for intracranial aneurysms causing neuro-ophthalmologic signs ideally should be made at high-volume centers with access to both surgical and endovascular treatments. The status of the patient, location of the aneurysm, and experience of the treating physicians

  5. Endovascular treatment of intracranial aneurysms with bioactive Cerecyte coils: effects on treatment stability

    International Nuclear Information System (INIS)

    Geyik, Serdar; Yavuz, Kivilcim; Ergun, Onur; Koc, Osman; Cekirge, Saruhan; Saatci, Isil

    2008-01-01

    The Cerecyte coils were developed to improve long-term stability of embolized cerebral aneurysms by producing an increased fibrous reaction over the neck of the aneurysms. We report our preliminary clinical experience with mid-term follow-up. Seventy-eight consecutive patients with 84 intracranial aneurysms treated exclusively with Cerecyte coils were included in this study. Forty-eight aneurysms were ruptured and 36 were incidental. Twenty-two aneurysms were small with ( 25 mm). The embolization technique was the same with that in standard bare coiling. Immediate post-procedure angiography demonstrated complete aneurysm occlusion in 69%, neck remnant in 29.8% and incomplete occlusion in 1.2%. Follow-up angiography was obtained in 80 aneurysms in a period of time ranging from 6 months to 2 years. The overall recanalization rate was 11.3%, and the re-treatment rate was 6.3%; in the subgroup analysis, recanalization rates were 4.5% in S/S; 9.8% in S/W; and 33.3% in large aneurysms. The only giant aneurysm also showed recanalization. Procedure-related morbidity and mortality rates were 2.6% and 1.3%, respectively. Our midterm results showed a relatively low rate of recurrence compared to those reported for platinum coils with morbidity and mortality rates comparable to those with standard bare platinum coils. The efficacy of Cerecyte coils in the long term will be specifically addressed by the ongoing randomized Cerecyte coil trial. (orig.)

  6. Giant serpentine intracranial aneurysm: a case report

    International Nuclear Information System (INIS)

    Park, Jae Seong; Lee, Myeong Sub; Kim, Myung Soon; Kim, Dong Jin; Park, Joong Wha; Whang, Kum

    2001-01-01

    The authors present a case of giant serpentine aneurysm (a partially thrombosed aneurysm containing tortuous vascular channels with a separate entrance and outflow pathway). Giant serpentine aneurysms form a subgroup of giant intracranial aneurysms, distinct from saccular and fusiform varieties, and in this case, too, the clinical presentation and radiographic features of CT, MR imaging and angiography were distinct

  7. Spontaneous intracranial hemorrhage and multiple intracranial aneurysms in a patient with Roberts/SC phocomelia syndrome.

    Science.gov (United States)

    Wang, Anthony C; Gemmete, Joseph J; Keegan, Catherine E; Witt, Cordelie E; Muraszko, Karin M; Than, Khoi D; Maher, Cormac O

    2011-11-01

    Roberts/SC phocomelia syndrome (RBS) is a rare but distinct genetic disorder with an autosomal recessive inheritance pattern. It has been associated with microcephaly, craniofacial malformation, cavernous hemangioma, encephalocele, and hydrocephalus. There are no previously reported cases of RBS with intracranial aneurysms. The authors report on a patient with a history of RBS who presented with a spontaneous posterior fossa hemorrhage. Multiple small intracranial aneurysms were noted on a preoperative CT angiogram. The patient underwent emergency craniotomy for evacuation of the hemorrhage. A postoperative angiogram confirmed the presence of multiple, distal small intracranial aneurysms.

  8. Neonatal Intracranial Aneurysm Rupture Treated by Endovascular Management: A Case Report

    Directory of Open Access Journals (Sweden)

    Yi-Pei Tai

    2010-08-01

    Full Text Available Pediatric intracranial aneurysm rupture is rare, and is traditionally managed by surgical clipping. To the best of our knowledge, endovascular embolization of aneurysms in neonates has not previously been reported in Taiwan. We report a 9-day-old boy with intracranial aneurysms who underwent endovascular embolization, representing the youngest reported case in Taiwan. The 9-day-old boy presented with non-specific symptoms of irritable crying, seizure and respiratory distress. Computed tomography disclosed intraventricular hemorrhage, subarachnoid hemorrhage and focal intracranial hemorrhage around the right cerebellum. Subsequent computed tomographic angiography showed two sequential fusiform aneurysms, measuring 3 mm, located in the right side posterior inferior cerebellar artery (PICA. The patient underwent endovascular embolization because of the high risk of aneurysm re-rupture and the impossibility of surgical clipping due to the fusiform nature of the aneurysms. A postembolization angiogram revealed complete obliteration of the right distal PICA and proximal aneurysm. The distal PICA aneurysm was revascularized from the collateral circulation, but demonstrated a slow and delayed filling pattern. The patient's condition remained stable over the following week, and he was discharged without anticonvulsant therapy. No significant developmental delay was noted at follow-up at when he was 3 months old. This case emphasizes the need for clinical practitioners to consider a diagnosis of intracranial hemorrhage in neonates with seizure and increased intracranial pressure. Neonatal intracranial aneurysms can be treated safely by endovascular treatment.

  9. Vascular Variations Associated with Intracranial Aneurysms.

    Science.gov (United States)

    Orakdogen, Metin; Emon, Selin Tural; Somay, Hakan; Engin, Taner; Is, Merih; Hakan, Tayfun

    2017-01-01

    To investigate the vascular variations in patients with intracranial aneurysm in circle of Willis. We used the data on 128 consecutive intracranial aneurysm cases. Cerebral angiography images were analyzed retrospectively. Arteries were grouped as anterior cerebral arterial system (ACS), posterior cerebral arterial system (PCS) and middle cerebral arterial system (MCS) for grouping vascular variations. Lateralization, being single/multiple, gender; and also any connection with accompanying aneurysms" number, localization, dimension, whether bleeding/incidental aneurysm has been inspected. Variations were demonstrated in 57.8% of the cases. The most common variation was A1 variation (34.4%). The rate of variations was 36.7%, 24.2% and 10.2% respectively in ACS, PCS and MCS. MCS variations were significantly higher in males. Anterior communicating artery (ACoA) aneurysm observance rates were significantly higher and posterior communicating artery (PCoA) aneurysm and middle cerebral artery (MCA) aneurysm observance rates were significantly lower when compared to "no ACS variation detected" cases. In "PCS variation detected" cases, PCoA aneurysm observance rates and coexistence of multiple variations were significantly higher. The rate of vascular variations in patients with aneurysms was 57.8%. Arterial hypoplasia and aplasia were the most common variations. ACS was the most common region that variations were located in; they were mostly detected on the right side. Coexistence of ACoA aneurysm was higher than PCoA and MCA aneurysms. In the PCS variations group, PCoA aneurysms were the most common aneurysms that accompanying the variation and multiple variations were more common than in the other two groups. The variations in MCS were most common in males.

  10. A coil placement technique to treat intracranial aneurysm with incorporated artery

    Directory of Open Access Journals (Sweden)

    Chao-Bao Luo

    2018-03-01

    Conclusion: This technique is effective and safe in managing intracranial aneurysms with IAs. Although aneurysmal recurrence may occur in some aneurysms because of insufficient coiling, this technique is simpler to perform and requires less skill than other techniques. It can be an alternative option for treating some selected intracranial aneurysms with IAs.

  11. Intracranial arterial aneurysm vasculopathies: targeting the outer vessel wall

    International Nuclear Information System (INIS)

    Krings, Timo; Piske, Ronie L.; Lasjaunias, Pierre L.

    2005-01-01

    The pathogenesis of intracranial arterial aneurysms (AA) remains unclear, despite their clinical importance. An improved understanding of this disease is important in choosing therapeutic options. In addition to the ''classical'' berry-type aneurysm, there are various other types of intracranial AA such as infectious, dissecting or giant, partially-thrombosed aneurysms. From the clinician's perspective, the hypothesis that some of these intracranial AA might be due to abluminal factors has been proposed for several years. Indeed, this hypothesis and the empirical use of anti-inflammatory drugs in giant intracranial aneurysms have been confirmed by recent studies reporting that an enzyme involved in the inflammatory cascade (5-lipoxygenase or 5-LO) promotes the pathogenesis of specific aneurysms in humans. 5-LO generates different forms of leukotrienes which are potent mediators of inflammation. Adventitial inflammation leads to a weakening of the media from the abluminal part of the vessel wall due to the release of proinflammatory factors that invade the media, thereby degrading the extracellular matrix, the elastic lamina of the vascular wall, and, finally, the integrity of the vessel lumen. This in turn results in a dilation of the vessel and aneurysm formation. Moreover, neoangiogenesis of vasa vasorum is found in close proximity to 5-LO activated macrophages. In addition to this biological cascade, we argue that repeated subadventitial haemorrhages from the new vasa vasorum play an important role in aneurysm pathogenesis, due to a progressive increase in size mediated by the apposition of new layers of intramural haematoma within the vessel wall. Intracranial giant AA can therefore be regarded as a proliferative disease of the vessel wall induced by extravascular activity. (orig.)

  12. Cerebral foreign body reaction after carotid aneurysm stenting

    DEFF Research Database (Denmark)

    Lorentzen, Anastasia Orlova; Nome, Terje; Bakke, Søren Jacob

    2016-01-01

    Flow diverter stents are new important tools in the treatment of large, giant, or wide-necked aneurysms. Their delivery and positioning may be difficult due to vessel tortuosity. Common adverse events include intracranial hemorrhage and ischemic stroke, which usually occurs within the same day...

  13. Correlation between the clinical presentation and DSA of intracranial aneurysms

    International Nuclear Information System (INIS)

    Fang Chun; Hua Jia; Chen Kemin; Yin Yan; Ge Xin; Ying Yiping

    2001-01-01

    Objective: To evaluate the correlation between the clinical presentation and cerebral angiographic features of intracranial aneurysms. Methods: The authors retrospectively analyzed the relationship between the size, location and shape of 48 patient's cerebral aneurysms and their clinical presentations. Results: Clinical symptoms of cerebral aneurysms were related with their size, location and shape. Aneurysms in different location or at same location may cause similar symptoms or different symptoms. Rotation DSA is a useful examination supplemented to conventional DSA. Conclusions: The relationship between the location and the presentation of intracranial aneurysms is not specific. Rotation DSA plays important role in showing the characteristics of the cerebral aneurysms

  14. Magnetic resonance imaging of large and giant intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Kenichi; Saito, Akira; Nakasu, Yoko; Matsuda, Masayuki; Handa, Jyoji [Shiga University of Medical Science, Shiga (Japan); Todo, Giro

    1990-06-01

    Twelve large or giant intracranial aneurysms were studied with magnetic resonance (MR) imaging, and the findings were compared with those from computed tomographic (CT) scanning. Characteristic MR features of such aneurysms are: round, extra-axial mass with hypointensity rim; signal void, paradoxical enhancement, or even-echo rephasing due to blood flow; and laminated, eccentric thrombus with increased signal intensity when fresh, perianeurysmal hemorrhage occurs in the acute or subacute stage after aneurysmal rupture. MR imaging, however, often fails to identify or characterize the area of calcification. For the diagnosis of large or giant intracranial aneurysms, MR imaging is apparently superior to CT scanning in differentiating aneurysms from tumors, delineating the blood flow and intraluminal thrombus, and detecting the exact size of the aneurysm. It may also provide useful information concerning the growth mechanisms of aneurysms with or without thrombus formation. (author).

  15. Endovascular treatment of very small intracranial aneurysms

    DEFF Research Database (Denmark)

    Iskandar, A; Nepper-Rasmussen, J

    2011-01-01

    to large aneurysms (> 3 mm). However the data also suggest that endovascular treatment of very small aneurysms might be associated with an increased risk of procedural ruptures and mortality. At nine-month follow-up results indicate significantly less compaction in the very small aneurysms....... endovascular treatment was attempted in 956 consecutive intracranial aneurysms. Of 956 aneurysms, 111 aneurysms were very small aneurysms with a maximal diameter of 3 mm or less. We conducted a retrospective analysis of angiographic and clinical outcome following coiling of very small aneurysms...... aneurysms and less than 90% aneurysm occlusion in six aneurysms. Complications occurred in the treatment of 15 aneurysms, including eight procedural ruptures, six thromboembolic events and one case of early hemorrhage. Compared with larger aneurysms, treatment of very small aneurysms was associated...

  16. Multilevel segmentation of intracranial aneurysms in CT angiography images

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yan [Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California 94122 and University of Lyon, CREATIS, CNRS UMR 5220, INSERM U1206, UCB Lyon1, INSA Lyon, Lyon 69100 (France); Zhang, Yue, E-mail: y.zhang525@gmail.com [Veterans Affairs Medical Center, San Francisco, California 94121 and University of Lyon, CREATIS, CNRS UMR 5220, INSERM U1206, UCB Lyon1, INSA Lyon, Lyon 69100 (France); Navarro, Laurent [Ecole Nationale Superieure des Mines de Saint-Etienne, Saint-Etienne 42015 (France); Eker, Omer Faruk [CHU Montpellier, Neuroradiologie, Montpellier 34000 (France); Corredor Jerez, Ricardo A. [Ecole Polytechnique Federale de Lausanne, Lausanne 1015 (Switzerland); Chen, Yu; Zhu, Yuemin; Courbebaisse, Guy [University of Lyon, CREATIS, CNRS UMR 5220, INSERM U1206, UCB Lyon1, INSA Lyon, Lyon 69100 (France)

    2016-04-15

    Purpose: Segmentation of aneurysms plays an important role in interventional planning. Yet, the segmentation of both the lumen and the thrombus of an intracranial aneurysm in computed tomography angiography (CTA) remains a challenge. This paper proposes a multilevel segmentation methodology for efficiently segmenting intracranial aneurysms in CTA images. Methods: The proposed methodology first uses the lattice Boltzmann method (LBM) to extract the lumen part directly from the original image. Then, the LBM is applied again on an intermediate image whose lumen part is filled by the mean gray-level value outside the lumen, to yield an image region containing part of the aneurysm boundary. After that, an expanding disk is introduced to estimate the complete contour of the aneurysm. Finally, the contour detected is used as the initial contour of the level set with ellipse to refine the aneurysm. Results: The results obtained on 11 patients from different hospitals showed that the proposed segmentation was comparable with manual segmentation, and that quantitatively, the average segmentation matching factor (SMF) reached 86.99%, demonstrating good segmentation accuracy. Chan–Vese method, Sen’s model, and Luca’s model were used to compare the proposed method and their average SMF values were 39.98%, 40.76%, and 77.11%, respectively. Conclusions: The authors have presented a multilevel segmentation method based on the LBM and level set with ellipse for accurate segmentation of intracranial aneurysms. Compared to three existing methods, for all eleven patients, the proposed method can successfully segment the lumen with the highest SMF values for nine patients and second highest SMF values for the two. It also segments the entire aneurysm with the highest SMF values for ten patients and second highest SMF value for the one. This makes it potential for clinical assessment of the volume and aspect ratio of the intracranial aneurysms.

  17. Onyx combined with coiling embolization for endovascular treatment of complex intracranial ruptured aneurysms

    International Nuclear Information System (INIS)

    Wu Yongfa; Huang Qinghai; Yang Pengfei; Zhang Lei; Li Qiang; Liu Jianmin

    2011-01-01

    Objective: To study the therapeutic effect of Onyx combined with stent-assisted coiling in embolizing complex intracranial ruptured aneurysms. Methods: Onyx combined with stent-assisted coiling embolization was conducted in two patients with complex intracranial ruptured aneurysms. The clinical data were retrospectively analyzed. The related literature concerning intracranial complex aneurysm treated with Onyx was reviewed. Results: Two intracranial complex aneurysms were embolized with Onyx together with coils. The lesions were located at internal carotid arterial bifurcation (n=1) and at the anterior wall of internal carotid artery (n=1). Complete embolization of the aneurysms was achieved immediately after the procedure while the parent arteries remained patent. Conclusion: For the treatment of complex intracranial ruptured aneurysms Onyx combined with coiling embolization is safe, effective and feasible. This technique can improve the degree of embolization. To make the evaluation of the long-term efficacy further study is needed. (authors)

  18. Diagnosis and treatment of traumatic intracranial aneurysm in childhood

    International Nuclear Information System (INIS)

    Yu Juming; Fan Guoping; Zhong Weixing; Zhang Yongping; Peng Haiteng; Zhu Ming; Cheng Yongde

    2008-01-01

    Objective: To evaluate the diagnosis, safety and efficacy of interventional therapy and surgery for child traumatic intracranial aneurysms. Methods: Five patients with traumatic intracranial aneurysms including three males and two females, age ranged from 2 to 10 years old; 5 had undertaken CT and MR scanings. All of them showed traumatic subarachnoid hemorrhage in 2, intracerebral hematoma in the right occipital and the left temporal respectively in 2 and another one with somewhat bleeding at the posterior fossa and right trigone of lateral ventricles and subdural bleeding at the tentorium edge. The detailed vascular involvement diagnosis were made by DSA revealing one of left C1 segmental internal carotid artery traumatic aneurysm, one of the branch of right sylvian artery traumatic aneurysm, one of left middle cerebral artery traumatic aneurysm, one of left posterior cerebral artery traumatic aneurysm, one of the branch of right posterior inferior cerebellar artery traumatic aneurysm. Two of them were treated by embolization therapy with CDC and two by surgery. Results: The CDC embolization in 2 cases and the surgical operation for another 2 were all succeeded without death or complications. The last case was followed up closely. Conclusions: Traumatic intracranial aneurysm is rare in childhood but endovascular treatment with CDC and surgery is efficient and safe, yet the long-term efficacy is still relied on follow-up. (authors)

  19. Endovascular treatment of intracranial aneurysms using liquid polymer injection

    International Nuclear Information System (INIS)

    Liu Jianmin; Huang Qinghai; Xu Yi; Hong Bo

    2004-01-01

    Objective: To report our preliminary clinical experience in embolization of intracranial aneurysms with liquid polymer (Onyx). Methods: One case of posterior communicating artery aneurysm was treated with Onyx and microcoils, while the other one with multiple basilar aneurysms was treated by Onyx combined with stent-coiling technique. Results: All the aneurysms were totally occluded with patency of parent arteries. There was no procedure-related complication. The patients recovered well during clinical follow-up for 3 months. The angiographic follow-up in one patient showed the result was stable and Onyx was totally apart from the flow in parent artery. Conclusions: Short-term result suggests that endovascular treatment of intracranial aneurysms with liquid polymer is safe and effective, however more experience is needed. (authors)

  20. 3D printing of intracranial aneurysm based on intracranial digital subtraction angiography and its clinical application.

    Science.gov (United States)

    Wang, Jian-Li; Yuan, Zi-Gang; Qian, Guo-Liang; Bao, Wu-Qiao; Jin, Guo-Liang

    2018-06-01

    The study aimed to develop simulation models including intracranial aneurysmal and parent vessel geometries, as well as vascular branches, through 3D printing technology. The simulation models focused on the benefits of aneurysmal treatments and clinical education. This prospective study included 13 consecutive patients who suffered from intracranial aneurysms confirmed by digital subtraction angiography (DSA) in the Neurosurgery Department of Shaoxing People's Hospital. The original 3D-DSA image data were extracted through the picture archiving and communication system and imported into Mimics. After reconstructing and transforming to Binary STL format, the simulation models of the hollow vascular tree were printed using 3D devices. The intracranial aneurysm 3D printing simulation model was developed based on DSA to assist neurosurgeons in aneurysmal treatments and residency training. Seven neurosurgical residents and 15 standardization training residents received their simulation model training and gave high assessments for the educational course with the follow-up qualitative questionnaire. 3D printed simulation models based on DSA can perfectly reveal target aneurysms and help neurosurgeons select therapeutic strategies precisely. As an educational tool, the 3D aneurysm vascular simulation model is useful for training residents.

  1. History, Evolution, and Continuing Innovations of Intracranial Aneurysm Surgery.

    Science.gov (United States)

    Lai, Leon T; O'Neill, Anthea H

    2017-06-01

    Evolution in the surgical treatment of intracranial aneurysms is driven by the need to refine and innovate. From an early application of the Hunterian carotid ligation to modern-day sophisticated aneurysm clip designs, progress has been made through dedication and technical maturation of cerebrovascular neurosurgeons to overcome challenges in their practices. The global expansion of endovascular services has challenged the existence of aneurysm surgery, changing the complexity of the aneurysm case mix and volume that are referred for surgical repair. Concepts of how to best treat intracranial aneurysms have evolved over generations and will continue to do so with further technological innovations. As with the evolution of any type of surgery, innovations frequently arise from the criticism of current techniques. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Recurrence of ICA-PCoA aneurysms after neck clipping.

    Science.gov (United States)

    Sakaki, T; Takeshima, T; Tominaga, M; Hashimoto, H; Kawaguchi, S

    1994-01-01

    Between 1975 and 1992, 2211 patients underwent aneurysmal neck clipping at the Nara Medical University clinic and associated hospitals. The aneurysm in 931 of these patients was situated at the junction of the internal carotid artery (ICA) and posterior communicating artery (PCoA). Seven patients were readmitted 4 to 17 years after the first surgery because of regrowth and rupture of an ICA-PCoA aneurysmal sac that had arisen from the residual neck. On angiograms obtained following aneurysmal neck clipping, a large primitive type of PCoA was demonstrated in six patients and a small PCoA in one. A small residual aneurysm was confirmed in only two patients and angiographically complete neck clipping in five. Recurrent ICA-PCoA aneurysms were separated into two types based on the position of the old clip in relation to the new growth. Type 1 aneurysms regrow from the entire neck and balloon eccentrically. In this type, it is possible to apply the clip at the neck as in conventional clipping for a ruptured aneurysm. Type 2 includes aneurysms in which the proximal portion of a previous clip is situated at the corner of the ICA and aneurysmal neck and the distal portion on the enlarged dome of the aneurysm, because the sac is regrowing from a portion of the residual neck. In this type of aneurysm, a Sugita fenestrated clip can occlude the residual neck, overriding the old clip. Classifying these aneurysms into two groups is very useful from a surgical point of view because it is possible to apply a new clip without removing the old clip, which was found to be adherent to surrounding tissue.

  3. Toward understanding non-coding RNA roles in intracranial aneurysms and subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Huang Fengzhen

    2017-05-01

    Full Text Available Subarachnoid hemorrhage (SAH is a common and frequently life-threatening cerebrovascular disease, which is mostly related with a ruptured intracranial aneurysm. Its complications include rebleeding, early brain injury, cerebral vasospasm, delayed cerebral ischemia, chronic hydrocephalus, and also non neurological problems. Non-coding RNAs (ncRNAs, comprising of microRNAs (miRNAs, small interfering RNAs (siRNAs and long non-coding RNAs (lncRNAs, play an important role in intracranial aneurysms and SAH. Here, we review the non-coding RNAs expression profile and their related mechanisms in intracranial aneurysms and SAH. Moreover, we suggest that these non-coding RNAs function as novel molecular biomarkers to predict intracranial aneurysms and SAH, and may yield new therapies after SAH in the future.

  4. Small Intracranial Aneurysm Treatment Using Target (®) Ultrasoft (™) Coils.

    Science.gov (United States)

    Jindal, Gaurav; Miller, Timothy; Iyohe, Moronke; Shivashankar, Ravi; Prasad, Vikram; Gandhi, Dheeraj

    2016-06-01

    The introduction of small, soft, complex-shaped microcoils has helped facilitate the endovascular treatment of small intracranial aneurysms (IAs) over the last several years. Here, we evaluate the initial safety and efficacy of treating small IAs using only Target(®) Ultrasoft(™) coils. A retrospective review of a prospectively maintained clinical database at a single, high volume, teaching hospital was performed from September 2011 to May 2015. IAs smaller than or equal to 5.0 mm in maximal dimension treated with only Target(®) Ultrasoft(™) coils were included. A total of 50 patients with 50 intracranial aneurysms were included. Subarachnoid hemorrhage from index aneurysm rupture was the indication for treatment in 23 of 50 (46%) cases, and prior subarachnoid hemorrhage (SAH) from another aneurysm was the indication for treatment in eight of 50 (16%) cases. The complete aneurysm occlusion rate was 70% (35/50), the minimal residual aneurysm rate was 14% (7/50), and residual aneurysm rate was 16% (8/50). One intraoperative aneurysm rupture occurred. Three patients died during hospitalization from clinical sequelae of subarachnoid hemorrhage. Follow-up at a mean of 13.6 months demonstrated complete aneurysm occlusion in 75% (30/40) of cases, near complete occlusion in 15% (6/40) of cases, and residual aneurysm in 10% (4/40) of cases, all four of which were retreated. Our initial results using only Target(®) Ultrasoft(™) coils for the endovascular treatment of small intracranial aneurysms demonstrate initial excellent safety and efficacy profiles.

  5. Wingspan stent-assisted coiling of intracranial aneurysms with symptomatic parent artery stenosis: Experience in 35 patients with mid-term follow-up results

    International Nuclear Information System (INIS)

    Gao Xu; Liang Guobiao; Li Zhiqing; Wei Xuezhong; Wang Xiaogang; Zhang Haifeng; Feng Sizhe; Lin Jun

    2012-01-01

    Background: There is a potential risk of aneurysm rupture after parent artery revascularization because of increased blood flow. The purpose of this study is to assess the efficacy and safety of Wingspan stent-assisted coil embolization in the treatment of intracranial aneurysms with symptomatic parent artery stenosis. Methods: Thirty-five consecutive patients (19 men, 16 women; age range, 48–79 years; mean age, 60.4 years) harboring 35 unruptured wide-necked or fusiform intracranial aneurysms (mean size 6.8 mm; range 2.5–18 mm.) with symptomatic parent artery stenosis (mean degree 71.1%; range 50–92%) were treated with the Wingspan stent-assisted coiling. Twenty-four lesions were located in the anterior circulation and eleven in the posterior circulation. Patients were premedicated with antiplatelet therapy consisting of aspirin 300 mg and clopidogrel 75 mg for at least 3 days before the procedure. Following pre-dilatation and stent placement, a coiling microcatheter entered the aneurysm through the interstices of the stent, and then coiling was performed. After the procedure, clopidogrel 75 mg daily was recommended for an additional 30 days, and aspirin 100 mg was recommended throughout follow-up. For all patients, clinical follow-up was conducted by clinic visitation, or telephone interview. Angiographic follow-up with DSA was recommended at 6 months and 1 year after the procedure. Angiography follow-up (mean time 10.6 months) was obtained in 31 cases (88.6%). The technical feasibility of the procedure, procedure-related complications, angiographic results, clinical outcome and follow-up angiography were evaluated. Results: In every case, technical success was achieved. The degree of stenosis was reduced from 71.1% to 17.4% after balloon angioplasty and stenting. Immediate angiography demonstrated complete occlusion in 25 cases (71.4%), neck remnant in 7 cases (20.0%), and incomplete occlusion in 3 cases (8.6%). Procedure-related morbidity occurred in two

  6. Growth-mechanism of giant intracranial aneurysms; demonstration by CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Schubiger, O.; Valavanis, A.; Wichmann, W.

    1987-05-01

    In four cases of giant intracranial aneurysm, CT demonstrated a hyperdense open-, or closed-ring structure at the periphery of the aneurysm. Surgery in two of the cases demonstrated that this peripheral hyperdensity represents fresh clot inside the wall of the thrombosed mass. An analogy is established between giant intracranial aneurysms, chronic subdural hematomas and growing encapsulated intracerebral hematomas. The common feature of the three entities is slow growth by recurrent hemorrhages into the lesion. It is proven that growth of chronic subdural hematomas and of growing encapsulated hematomas is related to recurrent hemorrhage from capillaries sprouting within the membrane of the lesion. The highly vascularized membranous wall of a giant intracranial aneurysm seems to behave like the membrane of a chronic subdural hematoma. It is suggested that the giant intracranial aneurysm grows by recurrent hemorrhage into its wall and behaves like growing encapsulated hematomas.

  7. Evaluation of Aneurysm Neck Angle Change After Endovascular Aneurysm Repair Clinical Investigations

    Energy Technology Data Exchange (ETDEWEB)

    Le, Trong Binh; Moon, Mi Hyoung [Inha University Hospital, Endovascular Training Center (Korea, Republic of); Jeon, Yong Sun, E-mail: radjeon@inha.ac.kr [Inha University Hospital, Inha University School of Medicine, Department of Radiology (Korea, Republic of); Hong, Kee Chun [Inha University School of Medicine, Department of Vascular Surgery (Korea, Republic of); Cho, Soon Gu [Inha University Hospital, Inha University School of Medicine, Department of Radiology (Korea, Republic of); Park, Keun-Myoung [Inha University School of Medicine, Department of Vascular Surgery (Korea, Republic of)

    2016-05-15

    PurposeTo evaluate the aneurysm neck angle changes and post-endovascular aneurysm repair (EVAR) complications.MethodsWe retrospectively analyzed 72 cases of elective EVAR for abdominal aortic aneurysm among 109 consecutive cases from December 2005 to April 2014. Patients were divided into angulated and non-angulated groups. The angulated group was defined as neck angulation ≥60°. Neck angle was evaluated pre- and post-EVAR during short- (within 1 month), mid- (3–6 months), and long-term (>1 year) follow-up. Aneurysm sac diameter change, aneurysm neck morphology other than angulation, endoleaks, and other post-procedural complications were also documented.ResultsA total of 34 patients were enrolled in the angulated group. There were no statistical differences in age, sex, follow-up duration, and aneurysm neck profile between the two groups (p > 0.05). Both groups showed statistically significant and consistent decreases in angulation during the follow-up period (p < 0.01). The angulated group revealed 22.45 % more straightening than the non-angulated group. Recoil of the Endurant device occurred in the angulated group. No statistically significant intergroup differences were observed in any endoleaks, complications, or re-intervention rates (p > 0.05). Pre-EVAR angle was the only predictor for post-procedural angle change (p < 0.001).ConclusionEVAR is applicable for patients with highly angulated aneurysm neck and provides consistent neck straightening over long-term follow-up. Recoil was evident in the angulated group using the Endurant device.

  8. Shared Genetic Risk Factors of Intracranial, Abdominal, and Thoracic Aneurysms

    NARCIS (Netherlands)

    van 't Hof, Femke N G; Ruigrok, Ynte M; Lee, Cue Hyunkyu; Ripke, Stephan; Anderson, Graig; de Andrade, Mariza; Baas, Annette F; Blankensteijn, Jan D; Böttinger, Erwin P; Bown, Matthew J; Broderick, Joseph; Bijlenga, Philippe; Carrell, David S; Crawford, Dana C; Crosslin, David R; Ebeling, Christian; Eriksson, Johan G; Fornage, Myriam; Foroud, Tatiana; von Und Zu Fraunberg, Mikael; Friedrich, Christoph M; Gaál, Emília I; Gottesman, Omri; Guo, Dong-Chuan; Harrison, Seamus C; Hernesniemi, Juha; Hofman, Albert; Inoue, Ituro; Jääskeläinen, Juha E; Jones, Gregory T; Kiemeney, Lambertus A L M; Kivisaari, Riku; Ko, Nerissa; Koskinen, Seppo; Kubo, Michiaki; Kullo, Iftikhar J; Kuivaniemi, Helena; Kurki, Mitja I; Laakso, Aki; Lai, Dongbing; Leal, Suzanne M; Lehto, Hanna; LeMaire, Scott A; Low, Siew-Kee; Malinowski, Jennifer; McCarty, Catherine A; Milewicz, Dianna M; Mosley, Thomas H; Nakamura, Yusuke; Nakaoka, Hirofumi; Niemelä, Mika; Pacheco, Jennifer; Peissig, Peggy L; Pera, Joanna; Rasmussen-Torvik, Laura; Ritchie, Marylyn D; Rivadeneira, Fernando; van Rij, Andre M; Santos-Cortez, Regie Lyn P; Saratzis, Athanasios; Slowik, Agnieszka; Takahashi, Atsushi; Tromp, Gerard; Uitterlinden, André G; Verma, Shefali S; Vermeulen, Sita H; Wang, Gao T; Han, Buhm; Rinkel, Gabriël J E; de Bakker, Paul I W

    2016-01-01

    BACKGROUND: Intracranial aneurysms (IAs), abdominal aortic aneurysms (AAAs), and thoracic aortic aneurysms (TAAs) all have a familial predisposition. Given that aneurysm types are known to co-occur, we hypothesized that there may be shared genetic risk factors for IAs, AAAs, and TAAs. METHODS AND

  9. Shared genetic risk factors of intracranial, abdominal, and thoracic aneurysms

    NARCIS (Netherlands)

    van 't Hof, Femke N G; Ruigrok, Ynte M; Lee, Cue Hyunkyu; Ripke, Stephan; Anderson, Graig; de Andrade, Mariza; Baas, Annette F; Blankensteijn, Jan D; Böttinger, Erwin P; Bown, Matthew J; Broderick, Joseph; Bijlenga, Philippe; Carrell, David S; Crawford, Dana C; Crosslin, David R; Ebeling, Christian; Eriksson, Johan G; Fornage, Myriam; Foroud, Tatiana; von Und Zu Fraunberg, Mikael; Friedrich, Christoph M; Gaál, Emília I; Gottesman, Omri; Guo, Dong-Chuan; Harrison, Seamus C; Hernesniemi, Juha; Hofman, Albert; Inoue, Ituro; Jääskeläinen, Juha E; Jones, Gregory T; Kiemeney, Lambertus A L M; Kivisaari, Riku; Ko, Nerissa; Koskinen, Seppo; Kubo, Michiaki; Kullo, Iftikhar J; Kuivaniemi, Helena; Kurki, Mitja I; Laakso, Aki; Lai, Dongbing; Leal, Suzanne M; Lehto, Hanna; LeMaire, Scott A; Low, Siew-Kee; Malinowski, Jennifer; McCarty, Catherine A; Milewicz, Dianna M; Mosley, Thomas H; Nakamura, Yusuke; Nakaoka, Hirofumi; Niemelä, Mika; Pacheco, Jennifer; Peissig, Peggy L; Pera, Joanna; Rasmussen-Torvik, Laura; Ritchie, Marylyn D; Rivadeneira, Fernando; van Rij, Andre M; Santos-Cortez, Regie Lyn P; Saratzis, Athanasios; Slowik, Agnieszka; Takahashi, Atsushi; Tromp, Gerard; Uitterlinden, André G; Verma, Shefali S; Vermeulen, Sita H; Wang, Gao T; Han, Buhm; Rinkel, Gabriël J E; de Bakker, Paul I W

    2016-01-01

    Background--Intracranial aneurysms (IAs), abdominal aortic aneurysms (AAAs), and thoracic aortic aneurysms (TAAs) all have a familial predisposition. Given that aneurysm types are known to co-occur, we hypothesized that there may be shared genetic risk factors for IAs, AAAs, and TAAs. Methods and

  10. GDC 360 for the endovascular treatment of intracranial aneurysms: a matched-pair study analysing angiographic outcomes with GDC 3D coils in 38 patients

    International Nuclear Information System (INIS)

    Taschner, Christian A.; Thines, Laurent; Lejeune, Jean-Paul; El-Mahdy, Mohamed; Rachdi, Henda; Gauvrit, Jean-Yves; Pruvo, Jean-Pierre; Leclerc, Xavier

    2009-01-01

    The purpose of this study was to determine whether coil embolisation with a new complex-shaped Guglielmi Detachable Coil (GDC 360 ; Boston Scientific Neurovascular, Fremont, CA, USA) has any effect on the stability of aneurysm occlusion. Fifty-one consecutive patients with intracranial aneurysms treated with GDC 360 were included. Angiographic results and adverse neurological events during the follow-up period were recorded. For 38 patients treated with GDC 360 with available follow-up data, a corresponding patient treated with GDC 3D was identified from our database. Matches were sought for rupture status, location, aneurysmal size, and neck size. The angiographic outcome of these matched controls at 6 months was compared to aneurysms treated with GDC 360 . Initial angiographic controls for 38 patients treated with GDC 360 showed complete occlusion in 32 aneurysms, and a neck remnant in six. At 6-month follow-up, complete occlusion was found in 29, a neck remnant in eight, and a residual aneurysm in one. One patient treated with GDC 360 needed retreatment for a major recanalisation. In 38 matched patients treated with GDC 3D, initial angiographic controls found complete aneurysmal occlusion in 30 aneurysms and a residual neck in 8. At 6-month follow-up, 24 aneurysms were completely occluded, ten showed a neck remnant, and residual aneurysms were seen in four. Four patients, treated with GDC 3D, were retreated for major aneurysm recanalisations. Our data suggests that endovascular coil embolisation with GDC 360 might improve long-term stability of coiled aneurysms when compared to GDC 3D. (orig.)

  11. Mannitol-induced rebleeding from intracranial aneurysm. Case report

    DEFF Research Database (Denmark)

    Rosenørn, J; Westergaard, L; Hansen, P H

    1983-01-01

    A case is presented in which rebleeding from an intracranial saccular aneurysm occurred a few minutes after intravenous administration of mannitol during surgery. The relationship between the reducing effect of mannitol on elevated intracranial pressure and the increased pressure gradient across...

  12. Mannitol-induced rebleeding from intracranial aneurysm. Case report

    DEFF Research Database (Denmark)

    Rosenørn, J; Westergaard, L; Hansen, P H

    1983-01-01

    A case is presented in which rebleeding from an intracranial saccular aneurysm occurred a few minutes after intravenous administration of mannitol during surgery. The relationship between the reducing effect of mannitol on elevated intracranial pressure and the increased pressure gradient across ...

  13. Microsurgical treatment of carotid-ophthalmic aneurysm associated with multiple anterior and posterior circulation aneurysms

    Science.gov (United States)

    Wang, Jiantao; Kan, Zhisheng; Wang, Shuo

    2017-01-01

    Abstract Background: The clipping of multiple intracranial aneurysms in 1 stage is uncommon. In this case, we report clipping of an ophthalmic aneurysm associated with multiple anterior and posterior circulation aneurysms via the Dolenc approach. Methods: The main symptoms of the patient are headache, along with nausea and vomiting. The patient's arteriogram revealed a wide-necked aneurysm of the right ophthalmic artery, an irregular aneurysm of the anterior communicating artery, and a basilar artery aneurysm. The surgical intervention for these aneurysms is a challenge because of the complex anatomical relationship with the surrounding structures. The 3 aneurysms, which were not amenable to a single intervention, were successfully clipped in 1 incision. Results: After surgery, the patient reported feeling well. One year after surgery, the patient had no SAH recurrence. Conclusions: Occasionally, surgical treatment was used even for aneurysms of the carotid-ophthalmic artery with aneurysms of anterior communicating artery and basilar artery, which are contraindicated for interventional therapy. PMID:28422878

  14. The Effect of Inlet Waveforms on Computational Hemodynamics of Patient-Specific Intracranial Aneurysms

    OpenAIRE

    Xiang, J.; Siddiqui, A.H.; Meng, H.

    2014-01-01

    Due to the lack of patient-specific inlet flow waveform measurements, most computational fluid dynamics (CFD) simulations of intracranial aneurysms usually employ waveforms that are not patient-specific as inlet boundary conditions for the computational model. The current study examined how this assumption affects the predicted hemodynamics in patient-specific aneurysm geometries. We examined wall shear stress (WSS) and oscillatory shear index (OSI), the two most widely studied hemodynamic qu...

  15. Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Markson, G.; Dorsch, N.W.C.; McMahon, J.

    2001-01-01

    The goal of this study was to assess the usefulness of spiral CT angiography (CTA) with three- dimensional reconstructions in defining intracranial aneurysms, particularly around the Circle of Willis. Two hundred consecutive patients with angiographic and/or surgical correlation were studied between 1993 and 1998, with CTA performed on a GE HiSpeed unit and Windows workstation. The following clinical situations were evaluated: conventional CT suspicion of an aneurysm; follow-up of treated aneurysm remnants or of untreated aneurysms; subarachnoid haemorrhage (SAH) and negative angiography; family or past aneurysm history; and for improved definition of aneurysm anatomy. Spiral CTA detected 140 of 144 aneurysms, and an overall sensitivity of 97%, including 30 of 32 aneurysms 3 mm or less in size. In 38 patients with SAH and negative angiography, CTA found six of the seven aneurysms finally diagnosed. There was no significant artefact in 17 of 23 patients (74%) with clips. The specificity of CTA was 86% with 8 false-positive cases. Spiral CTA is very useful in demonstrating intracranial aneurysms. (orig.)

  16. Feasibility of magnetic resonance angiography (MRA) follow-up as the primary imaging modality after coiling of intracranial aneurysms

    International Nuclear Information System (INIS)

    Bakker, Nicolaas A.; Metzemaekers, Jan D. M.; Dijk, J. Marc C. van; Mooij, Jan Jakob A.; Groen, Rob J. M.; Westerlaan, Henriette E.; Eshghi, Omid S.

    2010-01-01

    Background: Digital subtraction angiography (DSA) is still regarded as the gold standard for detecting residual flow in treated aneurysms. Recent reports have also shown excellent results from magnetic resonance angiography (MRA) imaging. This is an important observation, since DSA is associated with a risk of medical complications, is time consuming, and is more expensive. Purpose: To determine whether MRA could replace conventional DSA and serve as the primary postinterventional imaging modality in patients with coiled intracranial aneurysms. Material and Methods: We studied a prospectively enrolled cohort of 190 patients treated endovascularly for a first-ruptured and/or unruptured intracranial aneurysm between January 2004 and December 2008. The imaging protocol included a 1.5T time-of-flight (TOF) MRA and a DSA at 3 months (on the same day) and, depending on comparability, a 1.5T TOF-MRA or DSA 1 year after treatment. All images were evaluated by a multidisciplinary panel. Results: In 141/190 patients, both an MRA and DSA were performed after 3-month follow-up. In 2/141 patients (1.4%), (small) neck remnants gave false-negative MRA results. In one patient (0.7%), this led to additional neurosurgical clipping of the aneurysm. In 25/141 patients, future follow-up (>3 months) consisted of DSA because of various reasons. In 24/25 of these patients, primary MRA images alone would invariably have led to additional DSA imaging. Conclusion: The present study shows that 1.5T TOF-MRA is a feasible primary follow-up modality after coiling of intracranial aneurysms. Given our data, we now suggest that, in every patient with a coiled intracranial aneurysm, the first follow-up, 3 months after coiling, should be an MRA study. Only when this MRA is inconclusive (e.g., because of coil artifacts), or in the case of suspicion of recanalization, should DSA be performed additionally

  17. Flat detector CT and its applications in the endovascular treatment of wide-necked intracranial aneurysms—A literature review

    Energy Technology Data Exchange (ETDEWEB)

    Zwarzany, Łukasz, E-mail: zwarzany@gmail.com [Department of Radiology and Diagnostic Imaging, M. Curie Hospital, Arkońska 4, 71-455 Szczecin (Poland); Poncyljusz, Wojciech, E-mail: wponcyl@poczta.onet.pl [Departament of Interventional Radiology, Pomeranian Medical University, Neurointerventional Cath Lab MSW Hospital, Al. Powst. Wielkopolskich 72, 70-111 Szczecin (Poland); Burke, Thomas H., E-mail: tom.burke@microvention.com [Microvention – Terumo, Tustin, CA (United States)

    2017-03-15

    Highlights: • FDCT provides cross-sectional images of the intraluminal devices. • Contrast agent administration enables the evaluation of the surrounding vessels. • Artefacts generated by the coil mass are the major limitation of this imaging tool. • MAR software improves significantly the quality of the acquired images. • The examination can be performed during the procedure as well as in the follow-up. - Abstract: Flat detector CT (FDCT) provides cross sectional imaging within an angiographic suite and is increasingly gaining popularity in various areas of interventional radiology, as an alternative imaging modality. Its relatively high spatial resolution improves visualization of intraluminal devices such as intracranial stents or flow-diverters. Device deployment and positioning, in relation to the parent vessel and surrounding structures, are easily assessible with FDCT. Furthermore, with contrast agent administration, it expands the diagnostic capabilities of this new imaging tool. However, beam-hardening artifacts is a major limitation in some cases. The examination can be performed both during the endovascular procedure and for pre- and post-treatment imaging. Intravenous contrast agent injection reduces the risk of complications, making it possible to perform this examination in the outpatient settings. The aim of this paper is to present an overview of published studies reporting experience with FDCT in the field of endovascular neurosurgery and in particular, FDCT's contribution in treatment of wide-necked intracranial aneurysms. The authors have focused specifically on stent-assisted coiling and flow-diverter implantation, since obtaining proper parent vessel wall apposition of these devices is essential for short- and long-term procedural outcomes.

  18. Fourier analysis of intracranial aneurysms: towards an objective and quantitative evaluation of the shape of aneurysms

    International Nuclear Information System (INIS)

    Rohde, Stefan; Lahmann, Katharina; Nafe, Reinhold; Yan, Bernard; Berkefeld, Joachim; Beck, Juergen; Raabe, Andreas

    2005-01-01

    Shape irregularities of intracranial aneurysms may indicate an increased risk of rupture. To quantify morphological differences, Fourier analysis of the shape of intracranial aneurysms was introduced. We compared the morphology of 45 unruptured (UIA) and 46 ruptured intracranial aneurysms (RIA) in 70 consecutive patients on the basis of 3D-rotational angiography. Fourier analysis, coefficient of roundness and qualitative shape assessment were determined for each aneurysm. Morphometric analysis revealed significantly smaller coefficient of roundness (P<0.02) and higher values for Fourier amplitudes numbers 2, 3 and 7 (P<0.01) in the RIA group, indicating more complex and irregular morphology in RIA. Qualitative assessment from 3D-reconstructions showed surface irregularities in 78% of RIA and 42% of UIA (P<0.05). Our data have shown significant differences in shape between RIA and UIA, and further developments of Fourier analysis may provide an objective factor for the assessment of the risk of rupture. (orig.)

  19. Combined treatment for complex intracranial aneurysm

    Directory of Open Access Journals (Sweden)

    Chiriac A.

    2015-06-01

    Full Text Available Complex aneurysms often cannot be completely excluded by a single approaches. Today successful treatment of these lesions requires a combination between microsurgical and endovascular techniques. Planning of combined treatment require a very good understanding of aneurysm anatomy and a close collaboration between neurosurgeon and neuroendovascular interventionist. Endovascular coiling can usually be used as early treatment for a partially aneurysm occlusion including the ruptured area and followed by definitive clipping. On the other hand microsurgical clipping also can be used as first treatment for complex aneurysm neck reconstruction, allowing successful secondary placement of coils inside the remnant aneurysm sac

  20. Enterprise Deployment Through PulseRider To Treat Anterior Communicating Artery Aneurysm Recurrence.

    Science.gov (United States)

    Valente, Iacopo; Limbucci, Nicola; Nappini, Sergio; Rosi, Andrea; Laiso, Antonio; Mangiafico, Salvatore

    2018-02-01

    PulseRider (Pulsar Vascular, Los Gatos, California, USA) is a new endovascular device designed to treat wide-neck bifurcation intracranial aneurysms. Deployment of a stent through a PulseRider to treat an aneurysm's recurrence has never been described before. We report the case of a 55-year-old man who underwent coiling of an 8-mm anterior communicating artery aneurysm with assistance of a PulseRider neck reconstruction device. The 6-month digital subtraction angiography control showed aneurysm recurrence, so we deployed an Enterprise 2 closed-cell stent (Codman, Miami Lakes, Florida, USA) in the A1-A2 segment passing across the previously implanted PulseRider. Enterprise correctly expanded and allowed for adequate coiling of the aneurysm. An Enterprise stent can be safely opened through a PulseRider in order to treat aneurysm recurrence. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Application of a novel retrievable self-expanding stent in intracranial aneurysm treatment

    International Nuclear Information System (INIS)

    Yang Zhigang; Liu Jianmin; Xu Yi; Huang Qinghai; Hong Bo; Zhao Wenyuan; Zhao Rui

    2008-01-01

    Objective: To assess the value of a novel retrievable self-expanding stent system (LEO) in intracranial aneurysm treatment. Methods: 43 patients with 44 intracranial aneurysms treated with LEO stent were retrospectively analized, including 16 aneurysms with single-stent deployment, 25 with stent-assisted technique, 2 with double-stent deployment and one with double-stent assisted coils. Follow up was carried out through imaging and clinical course. Results: The stent was easy for repositioning and all the stents were delivered successfully, except 1 stent with unsatisfactory position, 1 with acute in-stent thrombosis. During follow up, 1 case showed chronic in-stent thrombus and one with intimal hyperplasia. 22 aneurysms got compact coiled during procedure. Among 29 follow up cases, 72.4% aneurysms were cured or improved, 13.8% were stable and three dissection aneurysms enlarged within short period and two patients died. Conclusion: The new retrievable self-expanding stent (LEO), with the advantages of controlled delivery, easy deployment and choice for various types is a valuable system for vascular reconstruction of intracranial aneurysm with thrombosis. (authors)

  2. Patient- and Aneurysm-Specific Risk Factors for Intracranial Aneurysm Growth : A Systematic Review and Meta-Analysis

    NARCIS (Netherlands)

    Backes, Daan; Rinkel, Gabriel J E; Laban, Kamil G.; Algra, Ale; Vergouwen, Mervyn D I

    2016-01-01

    BACKGROUND AND PURPOSE—: Follow-up imaging is often performed in intracranial aneurysms that are not treated. We performed a systematic review and meta-analysis on patient- and aneurysm-specific risk factors for aneurysm growth. METHODS—: We searched EMBASE and MEDLINE for cohort studies describing

  3. The Role of Bone Subtraction Computed Tomographic Angiography in Determining Intracranial Aneurysms in Non-Traumatic Subarachnoid Hemorrhage

    International Nuclear Information System (INIS)

    Kayhan, Aysegul; Koc, Osman; Keskin, Suat; Keskin, Fatih

    2014-01-01

    The presence of blood in the subarachnoid space is an acute pathology with a serious risk of death and complications. The most common etiology (approximately 80%) is intracranial aneurysm. The aim of this study was to assess the role of bone subtracted computed tomographic angiography (BSCTA), a novel and noninvasive method for determining and characterizing intracranial aneurysms. Sixty consecutive patients with clinically suspected non-traumatic subarachnoid hemorrhage (SAH) were considered to enter the study. The subtraction quality was inadequate in ten patients; thus, they were excluded, leaving 50 patients (84.4%) in the study. Bone subtracted and non-subtracted 3D images were obtained from the BSCTA raw data sets. All images obtained by digital subtraction angiography (DSA), BSCTA, and computed tomographic angiography (CTA) were evaluated for the presence or absence of an aneurysm and the location, minimal sac diameter, and neck size ratio of the aneurysm. DSA was considered as the gold standard during the evaluation of the data. Of the 50 patients who participated in this study, 11 had no aneurysms as determined by both CTA and DSA. Examination of the remaining 39 patients revealed the presence of 51 aneurysms. While 3D-CTA could not detect six aneurysms that were located in the base of the skull, 3D-BSCTA easily detected them. Moreover, five aneurysms were only partially detected by 3D-CTA. According to this data, the sensitivity of 3D-BSCTA and 3D-CTA was calculated as 98% and 86.3%, respectively; the specificity was calculated as 100% and 90.9%, respectively, per aneurysm; and the sensitivity of 100% for 3D-BSCTA and 98% for 3D-CTA was achieved by using combined images with multi-planar reconstruction (MPR) and maximum intensity projection (MIP). BSCTA detected and characterized the aneurysms as well as DSA, and BSCTA and DSA gave concordant results in detecting aneurysms. BSCTA is easily accessible, less time consuming, and most importantly, a non

  4. The Role of Bone Subtraction Computed Tomographic Angiography in Determining Intracranial Aneurysms in Non-Traumatic Subarachnoid Hemorrhage

    Science.gov (United States)

    Kayhan, Aysegul; Koc, Osman; Keskin, Suat; Keskin, Fatih

    2014-01-01

    Background: The presence of blood in the subarachnoid space is an acute pathology with a serious risk of death and complications. The most common etiology (approximately 80%) is intracranial aneurysm. Objectives: The aim of this study was to assess the role of bone subtracted computed tomographic angiography (BSCTA), a novel and noninvasive method for determining and characterizing intracranial aneurysms. Patients and Methods: Sixty consecutive patients with clinically suspected non-traumatic subarachnoid hemorrhage (SAH) were considered to enter the study. The subtraction quality was inadequate in ten patients; thus, they were excluded, leaving 50 patients (84.4%) in the study. Bone subtracted and non-subtracted 3D images were obtained from the BSCTA raw data sets. All images obtained by digital subtraction angiography (DSA), BSCTA, and computed tomographic angiography (CTA) were evaluated for the presence or absence of an aneurysm and the location, minimal sac diameter, and neck size ratio of the aneurysm. DSA was considered as the gold standard during the evaluation of the data. Results: Of the 50 patients who participated in this study, 11 had no aneurysms as determined by both CTA and DSA. Examination of the remaining 39 patients revealed the presence of 51 aneurysms. While 3D-CTA could not detect six aneurysms that were located in the base of the skull, 3D-BSCTA easily detected them. Moreover, five aneurysms were only partially detected by 3D-CTA. According to this data, the sensitivity of 3D-BSCTA and 3D-CTA was calculated as 98% and 86.3%, respectively; the specificity was calculated as 100% and 90.9%, respectively, per aneurysm; and the sensitivity of 100% for 3D-BSCTA and 98% for 3D-CTA was achieved by using combined images with multi-planar reconstruction (MPR) and maximum intensity projection (MIP). BSCTA detected and characterized the aneurysms as well as DSA, and BSCTA and DSA gave concordant results in detecting aneurysms. Conclusions: BSCTA is

  5. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung [Mokdong Hospital, Ewha Womans University, Seoul (Korea, Republic of)

    2006-04-15

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure.

  6. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    International Nuclear Information System (INIS)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung

    2006-01-01

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure

  7. The 100 most cited articles in the endovascular management of intracranial aneurysms.

    Science.gov (United States)

    Maingard, Julian; Phan, Kevin; Ren, Yifan; Kok, Hong Kuan; Thijs, Vincent; Hirsch, Joshua A; Lee, Michael J; Chandra, Ronil V; Brooks, Duncan Mark; Asadi, Hamed

    2018-01-19

    Endovascular interventions for intracranial aneurysms have evolved substantially over the past several decades. A citation rank list is used to measure the scientific and/or clinical impact of an article. Our objective was to identify and analyze the characteristics of the 100 most cited articles in the field of endovascular therapy for intracranial aneurysms. We performed a retrospective bibliometric analysis between July and August 2017. Articles were searched on the Science Citation Index Expanded database using Web of Science in order to identify the most cited articles in the endovascular therapy of intracranial aneurysms since 1945. Using selected key terms ('intracranial aneurysm', 'aneurysm', 'aneurysmal subarachnoid', 'endovascular', 'coiling', 'stent-assisted', 'balloon-assisted', 'flow-diversion') yielded a total of 16 314 articles. The top 100 articles were identified and analyzed to extract relevant information, including citation count, authorship, article type, subject matter, institution, country of origin, and year of publication. Citations for the top 100 articles ranged from 133 to 1832. All articles were cited an average of 27 times per year. There were 45 prospective studies, including 7 level-II randomized controlled trials. Most articles were published in the 2000s (n=53), and the majority constituted level III or level IV evidence. Half of the top 100 articles arose from the USA. This study provides a comprehensive overview of the most cited articles in the endovascular management of intracranial aneurysms. It recognizes the contributions made by key authors and institutions, providing an important framework to an enhanced understanding of the evidence behind the endovascular treatment of aneurysms. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. THE ACOUSTIC DETECTION OF INTRACRANIAL ANEURYSMS - A CLINICAL-STUDY

    NARCIS (Netherlands)

    VANBRUGGEN, AC; MOOIJ, JJA; JOURNEE, HL

    1991-01-01

    A new recording method for the acoustical detection of intracranial aneurysms is presented. A study examining the capability of the method to discriminate between patients with an aneurysm and control patients by a simple, objective parameter is reported. Sound signals were recorded over the eyes,

  9. Traumatic intracranial aneurysm: a case report

    International Nuclear Information System (INIS)

    Kang, Si Won; Chun, Kyung Ah; Baik, Joon Hyun; Shin, Kyung Sub

    1994-01-01

    The occurrence of traumatic aneurysm is rare in head injury, but this complication is important as it is a potentially treatable cause delayed onset of intracranial hemorrhage. Authors report one case of traumatic aneurysm involving A1 and A2 junction of anterior cerebral artery. A-28-year-old man with traffic accident was examined with brain CT and cerebral angiography. 1) Brain CT: Initial scan shows multiple skull fractures involving right frontal bones with subarachnoid hemorrhage and pneumocephalus. Follow-up scan shows intracerebral hemorrhage at bilateral frontal lobes. 2) Cerebral angiography: A traumatic aneurysm which is slowly filling and delayed emptying is noted at the junctional portion of A1 and A2 segment of the anterior cerebral artery. This report demonstrates radiologic findings of traumatic aneurysm at anterior cerebral artery with the brief review of the literatures

  10. A failure of matrix metalloproteinase inhibition in the prevention of rat intracranial aneurysm formation

    International Nuclear Information System (INIS)

    Kaufmann, T.J.; Kallmes, D.F.; Marx, W.F.

    2006-01-01

    We tested the hypothesis that nonspecific matrix metalloproteinase (MMP) inhibition with doxycycline would decrease the incidence of intracranial aneurysm formation in a rat aneurysm model. We performed common carotid artery ligation on 96 Long-Evans rats. A treatment group of 48 animals was chosen at random to receive oral doxycycline (3 mg/kg) in addition to standard rat chow, and the control group of 48 animals received standard rat chow only. The major circle of Willis arteries was dissected at 1 year following carotid ligation, and the proportions of animals with aneurysms were compared between groups using Fisher's exact test. Four animals given oral doxycycline and ten control animals expired before 1 year. Of the examined animals, eight saccular intracranial aneurysms were found in 8 of 45 animals which had received doxycycline (17.8%) and seven saccular intracranial aneurysms were found in 7 of 37 control animals (18.9%). There was no significant difference in aneurysm formation between the doxycycline-treated and control groups (P=0.894). Nonspecific MMP inhibition with doxycycline is not effective in preventing intracranial aneurysm formation in a rat model. (orig.)

  11. [Analysis on Clinical Characteristic and Risk Factors of Patients Coexistence of Cerebral Artery Stenosis with Unruptured Intracranial Aneurysm].

    Science.gov (United States)

    Zhao, Hai-Yan; Han, Jin-Tao; Fan, Dong-Sheng

    2017-09-01

    To analyze the incidence of intracranial unruptured aneurysms in patients with intracranial artery stenosis,clinical features,and investigate the risk factors for unruptured intracranial aneurysms. Medical records from all patients performed with digital subtraction angiography (DSA) who had been treated at Peking University Third Hospital,China,from January 2012 to December 2015 were retrospectively reviewed to identify cases coexistence with cerebral artery stenosis and unruptured intracranial aneurysm. Of 273 patients with cerebral artery stenosis (≥50%),intracranial unruptured aneurysms was observed in 17 cases (6.23%) from age of 45 to 78,among them 8 (47.06%) were female and 9 (52.94%) were male. The incidence of unruptured intracranial aneurysm in male patients was 4.17% (9/216),and that of female was 14.4% (8/57). There was statistically significant difference between the male and female incidence of intracranial aneurysm ( P patients,16 (94.12%) aneurysms were located in the internal carotid artery (ICA) system,1 (5.88%) aneurysm was located at the tip of the basilar artery. In 11 cases (64.71%),aneurysms were located at the distal of the stenotic vessels,2 (11.76%) were located at the proximal of the stenotic vessels,and 4 cases (23.53%) of which the aneurysm and stenosis were not in the same artery. Logistic multivariate analysis showed that gender was an independent risk factor for aneurysms in patients with cerebral arterial stenosis. In the intracranial artery stenosis atients,the possibility of the occurrence of the aneurysm is much higher than the general population,and women were more prominent than man. Sex is an independent risk factor for aneurysms in patients with cerebral arterial stenosis.

  12. Intra-aneurysmal flow disruption after implantation of the Medina® Embolization Device depends on aneurysm neck coverage.

    Science.gov (United States)

    Frölich, Andreas Maximilian; Nawka, Marie Teresa; Ernst, Marielle; Frischmuth, Isabell; Fiehler, Jens; Buhk, Jan-Hendrik

    2018-01-01

    Flow disruption achieved by braided intrasaccular implants is a novel treatment strategy for cerebrovascular aneurysms. We hypothesized that the degree of intra-aneurysmal flow disruption can be quantified in vitro and is influenced by device position across the aneurysm neck. We tested this hypothesis using the Medina® Embolization Device (MED). Ten different patient-specific elastic vascular models were manufactured. Models were connected to a pulsatile flow circuit, filled with a blood-mimicking fluid and treated by two operators using a single MED. Intra-aneurysmal flow velocity was measured using conventional and high-frequency digital subtraction angiography (HF-DSA) before and after each deployment. Aneurysm neck coverage by the implanted devices was assessed with flat detector computed tomography on a three-point Likert scale. A total of 80 individual MED deployments were performed by the two operators. The mean intra-aneurysmal flow velocity reduction after MED implantation was 33.6% (27.5-39.7%). No significant differences in neck coverage (p = 0.99) or flow disruption (p = 0.84) were observed between operators. The degree of flow disruption significantly correlated with neck coverage (ρ = 0.42, 95% CI: 0.21-0.59, p = 0.002) as well as with neck area (ρ = -0,35, 95% CI: -0.54 --0.13, p = 0.024). On multiple regression analysis, both neck coverage and total neck area were independent predictors of flow disruption. The degree of intra-aneurysmal flow disruption after MED implantation can be quantified in vitro and varies considerably between different aneurysms and different device configurations. Optimal device coverage across the aneurysm neck improves flow disruption and may thus contribute to aneurysm occlusion.

  13. Treatment of a spontaneous intracranial dissecting aneurysm with stent-assisted coil embolization

    International Nuclear Information System (INIS)

    Irie, Keiko; Negoro, Makoto; Hayakawa, Motoharu; Hayashi, Junichi; Kanno, Tetsuo

    2003-01-01

    Arterial dissection is now recognized as an important cause of stroke. Most reported dissections involve the extracranial portion of the internal carotid artery (ICA) and vertebral arteries. Spontaneous dissecting aneurysms of the intracranial ICA are uncommon. Endovascular treatment for cerebral aneurysms has become widespread; however, the dissecting aneurysm is still difficult to treat if the parent artery has to be preserved. More recently, stenting has been advocated for use with endosaccular coiling, with the coils held in place by the stent. We herein report a spontaneous intracranial ICA dissecting aneurysm in a 51-year-old woman who was treated using a new technique of combined stent and coils. (orig.)

  14. Physiological remodeling of bifurcation aneurysms: preclinical results of the eCLIPs device.

    Science.gov (United States)

    Marotta, Thomas R; Riina, Howard A; McDougall, Ian; Ricci, Donald R; Killer-Oberpfalzer, Monika

    2018-02-01

    OBJECTIVE Intracranial bifurcation aneurysms are complex lesions for which current therapy, including simple coiling, balloon- or stent-assisted coiling, coil retention, or intrasaccular devices, is inadequate. Thromboembolic complications due to a large burden of intraluminal metal, impedance of access to side branches, and a high recurrence rate, due largely to the unmitigated high-pressure flow into the aneurysm (water hammer effect), are among the limitations imposed by current therapy. The authors describe herein a novel device, eCLIPs, and its use in a preclinical laboratory study that suggests the device's design and functional features may overcome many of these limitations. METHODS A preclinical model of wide-necked bifurcation aneurysms in rabbits was used to assess functional features and efficacy of aneurysm occlusion by the eCLIPs device. RESULTS The eCLIPs device, in bridging the aneurysm neck, allows coil retention, disrupts flow away from the aneurysm, leaves the main vessel and side branches unencumbered by intraluminal metal, and serves as a platform for endothelial growth across the neck, excluding the aneurysm from the circulation. CONCLUSIONS The eCLIPs device permits physiological remodeling of the bifurcation.

  15. Onyx HD-500 embolization of intracranial aneurysms: modified technique using continuous balloon inflation under conscious sedation.

    Science.gov (United States)

    Rahme, Ralph; Grande, Andrew; Jimenez, Lincoln; Abruzzo, Todd A; Ringer, Andrew J

    2014-08-01

    The conventional technique of intracranial aneurysm embolization using Onyx HD-500 (ev3 Neurovascular, Irvine, CA, USA) involves repetitive balloon inflation-deflation cycles under general anesthesia. By limiting parent artery occlusion to 5 minutes, this cyclic technique is thought to minimize cerebral ischemia. However, intermittent balloon deflation may lengthen procedure time and allow balloon migration, resulting in intimal injury or Onyx leakage. We report our experience using a modified technique of uninterrupted Onyx injection with continuous balloon occlusion under conscious sedation. All Onyx embolization procedures for unruptured aneurysms performed by the senior author (A.J.R.) between September 2008 and April 2010 were retrospectively reviewed. Demographic, clinical, angiographic, and procedural data were recorded. Twenty-four embolization procedures were performed in 21 patients with 23 aneurysms, including four recurrences. Twenty aneurysms (87%) involved the paraclinoid or proximal supraclinoid internal carotid artery. Size ranged from 2.5 to 24mm and neck diameter from 2 to 8mm. The modified technique was employed in 19 cases. All but one patient (94.4%) tolerated continuous balloon inflation. Complete occlusion was achieved in 20 aneurysms (83.3%) and subtotal occlusion in three (12.5%). Stable angiographic results were seen in 85%, 94%, 94%, and 100% of patients at 6, 12, 24, and 36months, respectively. There were no deaths. Permanent non-disabling neurological morbidity occurred in one patient (4.2%). Minor, transient, and/or angiographic complications were seen in three patients (12.5%), none related to the technique itself. Onyx embolization of unruptured intracranial aneurysms can be safely and effectively performed using continuous balloon inflation under conscious sedation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. MR angiography after coiling of intracranial aneurysms

    NARCIS (Netherlands)

    Schaafsma, J.D.

    2012-01-01

    Introduction Endovascular occlusion with detachable coils has become an alternative treatment to neurosurgical clipping of intracranial aneurysms over the last two decades. Its minimal invasiveness is the most important advantage of this treatment compared to clipping. The disadvantage of occlusion

  17. Tiny intracranial aneurysms: Endovascular treatment by coil embolisation or sole stent deployment

    International Nuclear Information System (INIS)

    Lu Jun; Liu Jiachun; Wang Lijun; Qi Peng; Wang Daming

    2012-01-01

    Purpose: Tiny intracranial aneurysms pose a significant therapeutic challenge for interventional neuroradiologists. The authors report their preliminary results of endovascular treatment of these aneurysms. Methods: Between January 2002 and December 2009, 52 tiny intracranial aneurysms (defined as ≤3 mm in maximum diameter) in 46 patients (22 men; mean age, 57.9 years) were treated by endosaccular coil embolisation or sole stent deployment in the parent artery. Of 52 aneurysms, 29 had ruptured and 23 remained unruptured. The initial angiographic results, procedural complications, and clinical outcomes were assessed at discharge. Imaging follow-up was performed with cerebral angiography. Results: One aneurysm coiling procedure failed because of unsuccessful micro-catheterization. Forty-three aneurysms were successfully coil embolized, of which complete occlusion was obtained in 14, subtotal occlusion in 18 and incomplete occlusion in 11. The other 8 aneurysms were treated by sole stent deployment in the parent artery. Procedural complications (2 intraprocedural ruptures and 3 thromboembolic events) occurred in 5 (9.6%) of 52 aneurysms, resulting in permanent morbidity in only 1 (2.2%, 1/46) patient. No rebleeding occurred during clinical follow-up (mean duration, 46.7 months). Of the 16 coiled aneurysms that receiving repetitive angiography, 6 initially completely and 3 subtotally occluded aneurysms remained unchanged, 4 initially subtotally and 3 incompletely occluded aneurysms progressed to total occlusion. Five sole stent deployed aneurysms received angiographic follow-up (mean duration, 10.0 months), of which 3 remained unchanged, 1 became smaller and 1 progressed to total occlusion. Conclusion: Endovascular treatment of tiny intracranial aneurysms is technical feasible and relatively safe. Coil embolisation seems to be effective in preventing early recanalisation, whereas sole stenting technique needs further investigation to determine its effectiveness.

  18. Quantifying Intracranial Aneurysm Wall Permeability for Risk Assessment Using Dynamic Contrast-Enhanced MRI: A Pilot Study.

    Science.gov (United States)

    Vakil, P; Ansari, S A; Cantrell, C G; Eddleman, C S; Dehkordi, F H; Vranic, J; Hurley, M C; Batjer, H H; Bendok, B R; Carroll, T J

    2015-05-01

    Pathological changes in the intracranial aneurysm wall may lead to increases in its permeability; however the clinical significance of such changes has not been explored. The purpose of this pilot study was to quantify intracranial aneurysm wall permeability (K(trans), VL) to contrast agent as a measure of aneurysm rupture risk and compare these parameters against other established measures of rupture risk. We hypothesized K(trans) would be associated with intracranial aneurysm rupture risk as defined by various anatomic, imaging, and clinical risk factors. Twenty-seven unruptured intracranial aneurysms in 23 patients were imaged with dynamic contrast-enhanced MR imaging, and wall permeability parameters (K(trans), VL) were measured in regions adjacent to the aneurysm wall and along the paired control MCA by 2 blinded observers. K(trans) and VL were evaluated as markers of rupture risk by comparing them against established clinical (symptomatic lesions) and anatomic (size, location, morphology, multiplicity) risk metrics. Interobserver agreement was strong as shown in regression analysis (R(2) > 0.84) and intraclass correlation (intraclass correlation coefficient >0.92), indicating that the K(trans) can be reliably assessed clinically. All intracranial aneurysms had a pronounced increase in wall permeability compared with the paired healthy MCA (P risk in anatomic (P = .02) and combined anatomic/clinical (P = .03) groups independent of size. We report the first evidence of dynamic contrast-enhanced MR imaging-modeled contrast permeability in intracranial aneurysms. We found that contrast agent permeability across the aneurysm wall correlated significantly with both aneurysm size and size-independent anatomic risk factors. In addition, K(trans) was a significant and size-independent predictor of morphologically and clinically defined high-risk aneurysms. © 2015 by American Journal of Neuroradiology.

  19. Microsurgical one-stage treatment of intracranial mirror aneurysms via bilateral frontolateral approaches

    Directory of Open Access Journals (Sweden)

    Hong-guang WANG

    2016-08-01

    Full Text Available Objective To investigate surgical strategies, clinical effects and complications of microsurgical one-stage treatment of intracranial mirror aneurysms via bilateral frontolateral approaches.  Methods Review clinical data of 18 cases with anterior circulation mirror aneurysms who underwent one-stage clipping via bilateral frontolateral approaches from July 2010 to July 2015 admitted to Department of Neurosurgery in Tianjin Huanhu Hospital. The operative efficacy was evaluated according to postoperative Glasgow Outcome Scale (GOS.  Results The 36 aneurysms in 18 patients were successfully clipped via bilateral frontolateral approaches at one-stage, including 18 posterior communicating artery (PCoA mirror aneurysms in 9 cases and 18 middle cerebral artery (MCA mirror aneurysms in 9 cases. GOS score of 5 was discovered in 16 cases, and 4 was discovered in 2 cases after operation. One case underwent ventriculoperitoneal shunting (VPS due to communicating hydrocephalus, one case got postoperative pulmonary infection and no death occurred. Intracranial CTA at 6 months postoperatively showed aneurysms of 18 patients were clipped completely, the parent artery blood flow was smooth, and no recurrence was found.  Conclusions Microsurgical one-stage clipping via bilateral frontolateral approaches for treating intracranial mirror aneurysms is a sugrical method with small incision, fitting surgical field, high safety, satisfactory effect and good prognosis, which is a new minimally invasive neurosurgical technique. DOI: 10.3969/j.issn.1672-6731.2016.08.012

  20. Multiple intracranial aneurysms following radiation therapy for pituitary adenoma. Case report

    Energy Technology Data Exchange (ETDEWEB)

    Nishi, Tohru; Matsukado, Yasuhiko; Kodama, Takafumi; Hiraki, Toshiro

    1987-03-01

    A 57-year-old man was admitted because of visual disturbance due to a recurrent pituitary adenoma. Nine years ago craniotomy was performed for the chromophobe adenoma and postoperative radiation therapy was applied with tumor dose of 50 Gy. Digital subtraction angiography indicated existence of an aneurysm at the carotid bifurcation and the finding was confirmed by conventional angiography, which revealed a saccular aneurysm and irregularity of the carotid walls. In surgery there were not only the saccular aneurysm found in the angiogram, but also three other fusiform aneurysms and severe sclerotic change at the major arteries adjoining the sellar region. Azzarelli et al. reported a fatal case due to the development of arteriosclerotic intracranial fusiform aneurysms following radiation therapy for suprasellar germinoma. This case is the second case which indicates the development of intracranial aneurysm following radiation therapy. Emphasis is placed on careful follow-up examination for radiated pituitary adenoma with computed tomography, digital subtraction angiography, or occasionally conventional angiography, even though the postoperative condition of the primary lesion is stabilized.

  1. Basilar artery aneurysm case presented with neck pain

    Directory of Open Access Journals (Sweden)

    Uygar Utku

    2013-04-01

    Full Text Available Neck pain related with disorders of the brain and neck vascular structures is not rare but importance was attached to a condition that is often overlooked. Tension as a sudden onset, radiating to the nape, the neck pain becomes unbearable and within seconds the raging 51-year-old female patient with aneurysm at the distal end of basilar artery was found. Case, the only sign of neck pain with unruptured basilar artery aneurysm is presented in terms of raising awareness on the subject.

  2. High-resolution 3D Magnetic Resonance angiography in the evaluation of neck vessels and intracranial circulation

    International Nuclear Information System (INIS)

    Villa, A.; Di Guglielmo, L.; Campani, R.; Nicolato, A.; D'Amato, M.; Rodriguez y Balena, R.

    1991-01-01

    Magnetic Resonance Angiography (MRA) is a modern vascular imaging technique which allows the non-invasive and direct imaging of vessels. The authors aimed at evaluating the diagnostic accuracy of MRA in the study of pathologic conditions in the neck and intracranial vessels; spatial resolution of the technique was also investigated. Twenty-four healthy volunteers and 82 patients suffering from various diseases of the head and neck vessels were included in the study. First of all, MRA capabilities ware investigated in visualizing normal vessels of both neck and intracranial circle. The diagnostic accuracy of the method was then evaluated in the study of vascular diseases, and the results compared with conventional/digital angiographic findings. The comparison demonstrated how stenoses and atherosclerotic plaques tend to be overestimated by MRA because of technical artifacts inherent to the technique itself, whereas vascular ulcerations and aneurysms are frequently underestimated. However, this data was steady and therefore evaluable- the exact knowledge of the artifacts making diagnosis reliable. The diagnostic and technical problems relative to the various vascular diseases are discussed. Finally, several hypotheses of diagnostic iter are suggested

  3. Prevalence of Unruptured Intracranial Aneurysm on MR Angiography

    International Nuclear Information System (INIS)

    Jeon, Tae Yeon; Jeon, Pyoung; Kim, Keon Ha

    2011-01-01

    To evaluate the prevalence of incidentally found unruptured intracranial aneurysms (UIAs) on the brain MR angiography (MRA) from a community-based general hospital. This was a prospectively collected retrospective study, carried out from January 2004 to December 2004. The subjects included 3049 persons from a community-based hospital in whom MRA was performed according to a standardized protocol in an outpatient setting. Age- and sex-specific prevalence of UIAs was calculated. The results by MRA were compared with intra-arterial digital subtraction angiography (DSA) findings. Unruptured intracranial aneurysms were found in 137 (5%) of the 3049 patients (M:F 43:94; mean age, 60.2 years). The prevalence of UIAs was 5% (n = 94) in women and 4% (n = 43) in men, respectively (p = 0.2046) and showed no age-related increase. The most common site of aneurysm was at the distal internal carotid artery (n = 64, 39%), followed by the middle cerebral artery (n = 40, 24%). In total, 99% of aneurysms measured less than 12 mm, and 93% of aneurysms measured less than 7 mm. Direct comparisons between MRA and DSA were available in 70 patients with 83 UIAs; the results revealed two false positive and two false negative results. This community-hospital based study suggested a higher prevalence of UIAs observed by MRA than previously reported. These findings should be anticipated in the design and use of neuroimaging in clinical practice.

  4. F2-isoprostanes and F4-neuroprostanes as markers of intracranial aneurysm development.

    Science.gov (United States)

    Syta-Krzyżanowska, Anna; Jarocka-Karpowicz, Iwona; Kochanowicz, Jan; Turek, Grzegorz; Rutkowski, Robert; Gorbacz, Krzysztof; Mariak, Zenon; Skrzydlewska, Elżbieta

    2018-04-24

    Intracranial aneurysms are common, occurring in about 1-2% of the population. Saccular aneurysm is a pouch-like pathological dilatation of an intracranial artery that develops when the cerebral artery wall becomes too weak to resist hemodynamic pressure and distends. The aim of this study was to determine whether the development of intracranial aneurysms and subarachnoid hemorrhage (SAH) affects neuronal phospholipid metabolism, and what influence different invasive treatments have on brain free radical phospholipid metabolism. The level of polyunsaturated fatty acid (PUFA) cyclization products - F2-isoprostanes and F4-neuroprostanes - was examined using liquid chromatography - mass spectrometry (LC-MS) in the plasma of patients with brain aneurysm and resulting subarachnoid hemorrhage. It was revealed that an aneurysm leads to the enhancement of lipid peroxidation with a significant increase in plasma F2-isoprostanes and F4-neuroprostanes (more than 3-fold and 11-fold, respectively) in comparison to healthy subjects. The rupture of an aneurysm results in hemorrhage and an additional increase in examined prostaglandin derivatives. The embolization and clipping of aneurysms contribute to a gradual restoration of metabolic homeostasis in brain cells, which is visible in the decrease in PUFA cyclization products. The results indicate that aneurysm development is associated with enhanced inflammation and oxidative stress, factors which favor lipid peroxidation, particularly in neurons, whose membranes are rich in docosahexaenoic acid, a precursor of F4-neuroprostanes.

  5. Genetics of intracranial aneurysms and related diseases

    NARCIS (Netherlands)

    van 't Hof, F.N.G.

    2017-01-01

    Intracranial aneurysms (IA) are dilatations of the vessel walls of cerebral arteries. Some can rupture and result in a subarachnoid hemorrhage (SAH), a severe subtype of stroke. This thesis is set out to elucidate the pathophysiology of IA from a genetic perspective. The main conclusions are: 1.

  6. Giant intracranial aneurysm embolization with a yield stress fluid material: insights from CFD analysis.

    Science.gov (United States)

    Wang, Weixiong; Graziano, Francesca; Russo, Vittorio; Ulm, Arthur J; De Kee, Daniel; Khismatullin, Damir B

    2013-01-01

    The endovascular treatment of intracranial aneurysms remains a challenge, especially when the aneurysm is large in size and has irregular, non-spherical geometry. In this paper, we use computational fluid dynamics to simulate blood flow in a vertebro-basilar junction giant aneurysm for the following three cases: (1) an empty aneurysm, (2) an aneurysm filled with platinum coils, and (3) an aneurysm filled with a yield stress fluid material. In the computational model, blood and the coil-filled region are treated as a non-Newtonian fluid and an isotropic porous medium, respectively. The results show that yield stress fluids can be used for aneurysm embolization provided the yield stress value is 20 Pa or higher. Specifically, flow recirculation in the aneurysm and the size of the inflow jet impingement zone on the aneurysm wall are substantially reduced by yield stress fluid treatment. Overall, this study opens up the possibility of using yield stress fluids for effective embolization of large-volume intracranial aneurysms.

  7. Clinical Application of Insertion Force Sensor System for Coil Embolization of Intracranial Aneurysms.

    Science.gov (United States)

    Matsubara, Noriaki; Miyachi, Shigeru; Izumi, Takashi; Yamada, Hiroyuki; Marui, Naoki; Ota, Keisuke; Tajima, Hayato; Shintai, Kazunori; Ito, Masashi; Imai, Tasuku; Nishihori, Masahiro; Wakabayashi, Toshihiko

    2017-09-01

    In endovascular embolization for intracranial aneurysms, it is important to properly control the coil insertion force. However, the force can only be subjectively detected by the subtle feedback experienced by neurointerventionists at their fingertips. The authors envisioned a system that would objectively sense and quantify that force. In this article, coil insertion force was measured in cases of intracranial aneurysm using this sensor, and its actual clinical application was investigated. The sensor consists of a hemostatic valve (Y-connector). A little flexure was intentionally added in the device, and it creates a bend in the delivery wire. The sensor measures the change in the position of the bent wire depending on the insertion force and translates it into a force value. Using this, embolization was performed for 10 unruptured intracranial aneurysms. The sensor adequately recorded the force, and it reflected the operators' usual clinical experience. The presence of the sensor did not affect the procedures. The sensor enabled the operators to objectively note and evaluate the insertion force and better cooperative handling was possible. Additionally, other members of the intervention team shared the information. Force records demonstrated the characteristic patterns according to every stage of coiling (framing, filling, and finishing). The force sensor system adequately measured coil insertion force in intracranial aneurysm coil embolization procedures. The safety of this sensor was demonstrated in clinical application for the limited number of patients. This system is useful adjunct for assisting during coil embolization for an intracranial aneurysm. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. A novel self-expanding fully retrievable intracranial stent (SOLO): experience in nine procedures of stent-assisted aneurysm coil occlusion

    International Nuclear Information System (INIS)

    Liebig, Thomas; Henkes, Hans; Reinartz, Joerg; Miloslavski, Elina; Kuehne, Dietmar

    2006-01-01

    The endovascular treatment of large and broad-necked aneurysms may require the use of a remodelling balloon or a stent system to achieve proper occlusion while maintaining the patency of the parent vessel. With the advent of self-expanding stents that can be delivered through a microcatheter, this kind of treatment has improved and problems with the previously used balloon expandable stents have largely been overcome. However, rigidity, insufficient trackability, and limited or non-existent retrievability may still restrict the application of self-expanding stents in some situations. Recently, a stent system with a new and different design has been introduced. This stent is highly flexible, fully retrievable, and can be delivered through a standard 0.021-inch microcatheter without a wire. We describe the first nine cases of stent-assisted coil occlusion of intracranial aneurysms with the use of this stent system. Between May and June of 2004, nine patients with large or broad-necked aneurysms were treated in two endovascular centres. The anatomy of the aneurysms and parent vessels, technical details of the procedure, performance of the stent system, and follow-up results were evaluated. In all procedures, the SOLO stent could be introduced without difficulty, in one procedure after positioning of a different self-expanding stent system had failed due to vessel tortuosity. Overlapping stents were placed in one patient and stent retrieval or repositioning was successfully performed in two procedures. There was no interference or limitation of subsequent coil occlusion after stenting. With regard to the stent, immediate postprocedure and follow-up angiograms were unremarkable in terms of thromboembolic events and signs of intimal hyperplasia. From our experience, we conclude that the SOLO stent shows satisfactory performance overall. Its unique design gives the stent properties that may help overcome some of the difficulties experienced with other self

  9. Genome screen in familial intracranial aneurysm

    Directory of Open Access Journals (Sweden)

    Langefeld Carl

    2009-01-01

    Full Text Available Abstract Background Individuals with 1st degree relatives harboring an intracranial aneurysm (IA are at an increased risk of IA, suggesting genetic variation is an important risk factor. Methods Families with multiple members having ruptured or unruptured IA were recruited and all available medical records and imaging data were reviewed to classify possible IA subjects as definite, probable or possible IA or not a case. A 6 K SNP genome screen was performed in 333 families, representing the largest linkage study of IA reported to date. A 'narrow' (n = 705 definite IA cases and 'broad' (n = 866 definite or probable IA disease definition were used in multipoint model-free linkage analysis and parametric linkage analysis, maximizing disease parameters. Ordered subset analysis (OSA was used to detect gene × smoking interaction. Results Model-free linkage analyses detected modest evidence of possible linkage (all LOD Conclusion These data suggest it is unlikely that there is a single common variant with a strong effect in the majority of the IA families. Rather, it is likely that multiple genetic and environmental risk factors contribute to the susceptibility for intracranial aneurysms.

  10. Is Marfan syndrome associated with symptomatic intracranial aneurysms?

    NARCIS (Netherlands)

    van den Berg, J. S.; Limburg, M.; Hennekam, R. C.

    1996-01-01

    BACKGROUND AND PURPOSE: Marfan syndrome is a heritable disorder of connective tissue caused by a deficiency of the glycoprotein fibrillin. In several publications and neurological textbooks, a relationship between Marfan syndrome and intracranial aneurysms has been assumed. METHODS: The records of

  11. First Indian single center experience with pipeline embolization device for complex intracranial aneurysms.

    Science.gov (United States)

    Cherian, Mathew P; Yadav, Manish Kumar; Mehta, Pankaj; Vijayan, K; Arulselvan, V; Jayabalan, Suresh

    2014-01-01

    Flow diversion is a novel method of therapy wherein an endoluminal sleeve, the flow diverter stent is placed across the neck of complex aneurysms to curatively reconstruct abnormal vasculature. We present the first Indian single center experience with the pipeline embolization device (PED) and 6 months follow-up results of 5 patients. Five complex or recurrent intracranial aneurysms in five patients were treated with PED. The patients were followed-up with magnetic resonance angiography (MRA) after 4 weeks and conventional angiography after 6 months. Feasibility, complications, clinical outcome, early 1-month MRA and 6 months conventional angiographic follow-up results were analyzed. Of the five aneurysms treated, four were in the anterior circulation and one in the posterior circulation. All five patients were treated with a single PED in each, and additionally coils were used in one patient. At 1-month MRA follow-up, complete occlusion was seen in 2 (40%) of the five cases. Post 6 months conventional angiography showed complete occlusion of the aneurysm sac in all five cases (100%). Side branch ostia were covered in three patients, all of which were patent (100%). There was no incidence of major neurological morbidity or mortality. One patient (20%) who had basilar top aneurysm experienced minor neurological disability after 5 days which partially improved. Pipeline embolization device for complex and recurrent aneurysms is technically feasible, safe, offers low complication rate, and definitive vascular reconstruction. PED can be used without fear of occlusion of covered eloquent side branches and perforators.

  12. International Subarachnoid Aneurysm Trial 2009 : Endovascular Coiling of Ruptured Intracranial Aneurysms Has No Significant Advantage Over Neurosurgical Clipping

    NARCIS (Netherlands)

    Bakker, Nicolaas A.; Metzemaekers, Jan D. M.; Groen, Rob J. M.; Mooij, Jan Jakob A.; Van Dijk, J. Marc C.

    In the May 2009 issue of The Lancet Neurology, the 5-year follow-up results of the International Subarachnoid Aneurysm Trial (ISAT) were published. The authors concluded that, although the significant difference between coiling and neurosurgical clipping of ruptured intracranial aneurysms in terms

  13. Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm.

    Science.gov (United States)

    Wang, Chao; Tian, Zhongbin; Liu, Jian; Jing, Linkai; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian

    2016-04-01

    Stent-assisted coiling technology has been widely used in the treatment of intracranial aneurysms. In the current study, we investigated the intra-aneurysmal hemodynamic alterations after stent implantation and their association with the aneurysm location. We first retrospectively studied 15 aneurysm cases [8 internal carotid artery-ophthalmic artery (ICA-OphA) aneurysms and 7 posterior communicating artery (PcoA) aneurysms] treated with Enterprise stents and coils. Then, based on the patient-specific geometries before and after stenting, we built virtual stenting computational fluid dynamics (CFD) simulation models. Before and after the stent deployment, the average wall shear stress (WSS) on the aneurysmal sac at systolic peak changed from 7.04 Pa (4.14 Pa, 15.77 Pa) to 6.04 Pa (3.86 Pa, 11.13 Pa), P = 0.001; the spatially averaged flow velocity in the perpendicular plane of the aneurysm dropped from 0.5 m/s (0.28 m/s, 0.7 m/s) to 0.33 m/s (0.25 m/s, 0.49 m/s), P = 0.001, respectively. Post stent implantation, the WSS in ICA-OphA aneurysms and PcoA aneurysms decreased by 14.4 % (P = 0.012) and 16.6 % (P = 0.018), respectively, and the flow velocity also reduced by 10.3 % (P = 0.029) and 10.5 % (P = 0.013), respectively. Changes in the WSS, flow velocity, and pressure were not significantly different between ICA-OphA and PcoA aneurysms (P > 0.05). Stent implantation did not significantly change the peak systolic pressure in either aneurysm type. After the stent implantation, both the intra-aneurysmal flow velocity and WSS decreased independently of aneurysm type (ICA-OphA and PcoA). Little change was observed in peak systolic pressure.

  14. Endovascular treatment of intracranial aneurysms with the p64 flow diverter stent: mid-term results in 35 patients with 41 intracranial aneurysms.

    Science.gov (United States)

    Morais, Ricardo; Mine, Benjamin; Bruyère, Pierre Julien; Naeije, Gilles; Lubicz, Boris

    2017-03-01

    The p64 flow diverter (FD) device is a fully resheathable and detachable stent dedicated for endovascular treatment (EVT) of intracranial aneurysms (IAs). We report our mid-term experience with this device. Between January 2015 and February 2016, we retrospectively identified, in our prospectively maintained database, all patients treated with p64 FDs in two institutions. Independent clinical follow-up was performed by a vascular neurologist. Imaging follow-up included a digitalized subtraction angiography (DSA) at 3, 6, and 12 months and a magnetic resonance angiography (MRA) at 12 months. Thirty-nine patients (22 women/17 men; median age 54 years) with 48 IAs (median aneurysm size 6.2 mm; mean neck size 3.4 mm) were identified. All IAs were saccular and unruptured. Failure of safe stent delivery occurred in 15% of cases (7/48 IAs) which were excluded. Transient neurological morbidity occurred in 2/35 patients (5.7%) including one delayed thromboembolic complication. No permanent morbidity or mortality was encountered. Complete aneurysmal occlusion at 3, 6, and 12 months was 20/30 (66.6%), 18/27 (66.6%), and 24/28 (85.7%), respectively. Intra-stent stenosis was observed in 9/29 patients (31%) and classified as moderate in 4/29 (13.7%) and mild in 5/29 patients (17.2%). These stenoses gradually improved over time, with only mild stenoses being identified at 6 months and at 12 months. In our small case series, the p64 FD stent appears safe and effective for EVT of IAs. A high occlusion rate and a low morbidity rate were observed.

  15. The intracranial aneurysm: cost-effective of the aneurysm intra-artery GDC embolization and the aneurysm incarcerated operation

    International Nuclear Information System (INIS)

    Pan Jie; Zhang Shizheng

    2008-01-01

    Objective: To evaluate the cost-effectiveness of the aneurysm intra-artery GDC embolization and the aneurysm clapping of intracranial aneurysm, and to give the instruction for the clinical practice. Methods: A case control study (1 vs. 1) was developed to evaluate the cost in hospital, the cost for return visit and the Quality-adusted Life-Year (QALY) and lifetime costs of the intra-artery GDC embolization and the aneurysm clapping of intraeranial aneurysm, under the matching of the age, sex, living place, the size and place of the aneurysm, and the Hunt and Hess score. Clinically effectiveness dates were derived from the medical records. Cost dates were derived from follow-up by telephones or letters. The correlation analysis was done with the SPSS 13.0. Results: The cost in hospital in AC group was (54 945±16 946)RMBs, which was higher than the ones in AE group (63 768±12 665) RMBs, (t=1.71, P 0.05). Conclusion: The results suggest that the two therapies have no difference in cost effective rate. Considering the physical and mental loss, the aneurysm intra-arteu GDC embolization was better than the aneurysm clapping for the patients with aneurysm that diameter less than 25 mm. (authors)

  16. Closed-Cell Stent-Assisted Coiling of Intracranial Aneurysms: Evaluation of Changes in Vascular Geometry Using Digital Subtraction Angiography.

    Science.gov (United States)

    Beller, Ebba; Klopp, David; Göttler, Jens; Kaesmacher, Johannes; Zimmer, Claus; Kirschke, Jan S; Prothmann, Sascha

    2016-01-01

    Stent-assisted coil embolization (SACE) plays an important role in the treatment of intracranial aneurysms. The purpose of this study was to investigate geometrical changes caused by closed-cell design stents in bifurcation and sidewall aneurysms. 31 patients with 34 aneurysms underwent SACE with closed-cell design stents. Inflow angle α, determined by aneurysm neck and afferent vessel, and angle between afferent and efferent vessel close to (δ1), respectively, more remote from the aneurysm neck (δ2) were graphically determined in 2D angiography projections. Stent assisted coiling resulted in a significant increase of all three angles from a mean value (±SEM) of α = 119° (±6.5°) pretreatment to 130° (±6.6°) posttreatment (P ≤ .001), δ1 = 129° (±6.4°) to 139° (±6.1°), (P ≤ .001) and δ2 = 115° (±8.4°) to 126° (±7.5°), (P ≤ .01). Angular change of δ1 in AcomA aneurysms was significant greater compared to sidewall aneurysms (26°±4.9° versus 8°± 2.3°, P ≤ .05). The initial angle of δ1 and δ2 revealed a significantly inverse relationship to the angle increase (δ1: r = -0.41, P ≤ .05 and δ2: r = -0.47, P ≤ .01). Moreover, angle δ1 was significantly higher in unruptured compared to ruptured aneurysms (135°±7.1° versus 103°±10.8°, P ≤ .05). Stent deployment modulates the geometry of the aneurysm-vessel complex, which may lead to favorable hemodynamic changes more similar to unruptured than to ruptured aneurysms. Our findings also suggest that the more acute-angled aneurysm-vessel anatomy, the larger the angular change. Further studies are needed to investigate whether these changes improve the clinical outcome.

  17. Closed-Cell Stent-Assisted Coiling of Intracranial Aneurysms: Evaluation of Changes in Vascular Geometry Using Digital Subtraction Angiography.

    Directory of Open Access Journals (Sweden)

    Ebba Beller

    Full Text Available Stent-assisted coil embolization (SACE plays an important role in the treatment of intracranial aneurysms. The purpose of this study was to investigate geometrical changes caused by closed-cell design stents in bifurcation and sidewall aneurysms.31 patients with 34 aneurysms underwent SACE with closed-cell design stents. Inflow angle α, determined by aneurysm neck and afferent vessel, and angle between afferent and efferent vessel close to (δ1, respectively, more remote from the aneurysm neck (δ2 were graphically determined in 2D angiography projections.Stent assisted coiling resulted in a significant increase of all three angles from a mean value (±SEM of α = 119° (±6.5° pretreatment to 130° (±6.6° posttreatment (P ≤ .001, δ1 = 129° (±6.4° to 139° (±6.1°, (P ≤ .001 and δ2 = 115° (±8.4° to 126° (±7.5°, (P ≤ .01. Angular change of δ1 in AcomA aneurysms was significant greater compared to sidewall aneurysms (26°±4.9° versus 8°± 2.3°, P ≤ .05. The initial angle of δ1 and δ2 revealed a significantly inverse relationship to the angle increase (δ1: r = -0.41, P ≤ .05 and δ2: r = -0.47, P ≤ .01. Moreover, angle δ1 was significantly higher in unruptured compared to ruptured aneurysms (135°±7.1° versus 103°±10.8°, P ≤ .05.Stent deployment modulates the geometry of the aneurysm-vessel complex, which may lead to favorable hemodynamic changes more similar to unruptured than to ruptured aneurysms. Our findings also suggest that the more acute-angled aneurysm-vessel anatomy, the larger the angular change. Further studies are needed to investigate whether these changes improve the clinical outcome.

  18. Morphology parameters for intracranial aneurysm rupture risk assessment.

    Science.gov (United States)

    Dhar, Sujan; Tremmel, Markus; Mocco, J; Kim, Minsuok; Yamamoto, Junichi; Siddiqui, Adnan H; Hopkins, L Nelson; Meng, Hui

    2008-08-01

    The aim of this study is to identify image-based morphological parameters that correlate with human intracranial aneurysm (IA) rupture. For 45 patients with terminal or sidewall saccular IAs (25 unruptured, 20 ruptured), three-dimensional geometries were evaluated for a range of morphological parameters. In addition to five previously studied parameters (aspect ratio, aneurysm size, ellipticity index, nonsphericity index, and undulation index), we defined three novel parameters incorporating the parent vessel geometry (vessel angle, aneurysm [inclination] angle, and [aneurysm-to-vessel] size ratio) and explored their correlation with aneurysm rupture. Parameters were analyzed with a two-tailed independent Student's t test for significance; significant parameters (P 41; 95% confidence interval, 1.03-1.92) and undulation index (odds ratio, 1.51; 95% confidence interval, 1.08-2.11) had the strongest independent correlation with ruptured IA. From the receiver operating characteristic analysis, size ratio and aneurysm angle had the highest area under the curve values of 0.83 and 0.85, respectively. Size ratio and aneurysm angle are promising new morphological metrics for IA rupture risk assessment. Because these parameters account for vessel geometry, they may bridge the gap between morphological studies and more qualitative location-based studies.

  19. Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography

    International Nuclear Information System (INIS)

    Tipper, G.; U-King-Im, J.M.; Price, S.J.; Trivedi, R.A.; Cross, J.J.; Higgins, N.J.; Farmer, R.; Wat, J.; Kirollos, R.; Kirkpatrick, P.J.; Antoun, N.M.; Gillard, J.H.

    2005-01-01

    AIM: The aim of this study was to assess the usefulness of 16-row multislice CT angiography (CTA) in evaluating intracranial aneurysms, by comparison with conventional digital subtraction angiography (DSA) and intraoperative findings. METHODS: A consecutive series of 57 patients, scheduled for DSA for suspected intracranial aneurysm, was prospectively recruited to have CTA. This was performed with a 16-detector row machine, detector interval 0.75 mm, 0.5 rotation/s, table speed 10 mm/rotation and reconstruction interval 0.40 mm. CTA studies were independently and randomly assessed by two neuroradiologists and a vascular neurosurgeon blinded to the DSA and surgical findings. Review of CTA was performed on workstations with an interactive 3D volume-rendered algorithm. RESULTS: DSA or intraoperative findings or both confirmed 53 aneurysms in 44 patients. For both independent readers, sensitivity and specificity per aneurysm of DSA were 96.2% and 100%, respectively. Sensitivity and specificity of CTA were also 96.2% and 100%, respectively. Mean diameter of aneurysms was 6.3 mm (range 1.9 to 28.1 mm, SD 5.2 mm). For aneurysms of less than 3 mm, CTA had a sensitivity of 91.7% for each reader. Although the neurosurgeon would have been happy to proceed to surgery on the basis of CTA alone in all cases, he judged that DSA might have provided helpful additional anatomical information in 5 patients. CONCLUSION: The diagnostic accuracy of 16-slice CTA is promising and appears equivalent to that of DSA for detection and evaluation of intracranial aneurysms. A strategy of using CTA as the primary imaging method, with DSA reserved for cases of uncertainty, appears to be practical and safe

  20. Abciximab in the treatment of acute in-stent thrombosis in patient with intracranial aneurysm

    International Nuclear Information System (INIS)

    Lilov, M.; Juszkat, R.; Petkov, A.; Todorov, I.

    2009-01-01

    A case of endovascular therapy via embolization of aneurysm in patient with SAH is performed selective brain angiography and find 3 aneurysms. The first is in right segment M1-M2 with diameter 5 mm, the second with wide neck is in supraclinoid portion of right internal carotid artery and the third in left M1-M2 segment. One month after embolization of ruptured aneurysm with coils BALT (Montmorency, France) and previous anticoagulation therapy was applied Leo stent (SALT) intraluminal in left internal carotid artery. Developed acute instent thrombosis recanalized with intraarterial use of abciximab. (authors)

  1. Acoustic detection of intracranial aneurysms : A decision analysis

    NARCIS (Netherlands)

    vanBruggen, AC; Dippel, DWJ; Habbema, JDF; Mooij, JJA

    1996-01-01

    We present a further evaluation of an improved recording method for the acoustic detection of intracranial aneurysms (ADA). A sensor was applied to the patient's eyes. Two measures were derived to summarize the power spectral density functions of the sound frequencies that were obtained from each

  2. Intracranial aneurysms: reproduction of the surgical view using 3D-CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Siablis, Dimitrios [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece)]. E-mail: siablis@med.upatras.gr; Kagadis, George C. [Department of Medical Physics, School of Medicine, University of Patras, Rion GR 26500 (Greece); Karamessini, Maria T. [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Konstantinou, Dimitrios [Department of Neurosurgery, School of Medicine, University of Patras, Rion GR 26500 (Greece); Karnabatidis, Dimitrios [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Petsas, Theodore [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Nikiforidis, George C. [Department of Medical Physics, School of Medicine, University of Patras, Rion GR 26500 (Greece)

    2005-07-01

    Our purpose was to describe a technique for simulating the surgical view of ruptured intracranial aneurysms, using volume-rendering techniques in spiral computed tomography (CT) angiography data. The 3D (three-dimensional) rendered images were assessed by a team consisted of four radiologists, one neurosurgeon and one medical physicist. The resultant 'surgical view' image was standardized in space using a three-dimensional coordinate system, which allowed for its reproduction in the operating theatre. The surgical views are a potentially useful tool for the surgical planning of intracranial aneurysms.

  3. Intracranial aneurysms: reproduction of the surgical view using 3D-CT angiography

    International Nuclear Information System (INIS)

    Siablis, Dimitrios; Kagadis, George C.; Karamessini, Maria T.; Konstantinou, Dimitrios; Karnabatidis, Dimitrios; Petsas, Theodore; Nikiforidis, George C.

    2005-01-01

    Our purpose was to describe a technique for simulating the surgical view of ruptured intracranial aneurysms, using volume-rendering techniques in spiral computed tomography (CT) angiography data. The 3D (three-dimensional) rendered images were assessed by a team consisted of four radiologists, one neurosurgeon and one medical physicist. The resultant 'surgical view' image was standardized in space using a three-dimensional coordinate system, which allowed for its reproduction in the operating theatre. The surgical views are a potentially useful tool for the surgical planning of intracranial aneurysms

  4. Preoperative cerebral aneurysm assessment by three-dimensional CT angiography. Feasibility of surgery without cerebral angiography

    International Nuclear Information System (INIS)

    Kashiwagi, Shiro; Yamashita, Katsuhiro; Kato, Shoichi; Ito, Haruhide; Kurokawa, Kensuke; Watanabe, Yutaka

    1999-01-01

    The purpose of this study is to assess the capability of three-dimensional CT angiography (3D-CTA) to replace conventional catheter angiography as a preoperative examination for unruptured intracranial aneurysms. A prospective study was designed to evaluate 18 patients with 20 unruptured intracranial aneurysms (13 middle cerebral artery aneurysms, 6 anterior communicating artery aneurysms, and 1 internal carotid posterior communicating artery aneurysm) who underwent surgery. There were 12 women and 6 men with the average age of 63 years old. All patients were initially diagnosed as having intracranial aneurysms by MR angiography, followed by 3D-CTA and conventional catheter angiography for confirmation. Three experienced neurosurgeons were in charge of the operations. One of the neurosurgeons (surgeon 1) was provided with only 3D-CTA as the preoperative radiological evaluation, while the others (surgeon 2 and 3) were given through assessments with MRA, 3D-CTA, and conventional angiography. Surgeon 1 carried out the operations under careful observation by the surgeons 2 and 3. Problems encountered by the surgeon 1 during surgery were recorded. Neck clipping in 19 aneurysms and dome wrapping in 1 were successfully accomplished. All patients were discharged without complication. Surgeries went smoothly in 16 aneurysms with 3D-CTA alone. Discrepancies between the 3D-CTA findings and microsurgical anatomy were noted in 4 aneurysms: the size of the neck was overestimated in 3 aneurysms, the relationships to parent arteries were obscure in 2 aneurysms, and a perforating artery problematic to neck clipping was missed in 1 aneurysms by 3D-CTA. The results of this study support the notion that 3D-CTA can replace conventional catheter angiography as preoperative examination in the majority of regular-sized anterior circulation aneurysms. Nevertheless, surgeons should recognize and be prepared for the fact that 3D-CTA can give false impression about the aneurysm neck and

  5. CFD: computational fluid dynamics or confounding factor dissemination? The role of hemodynamics in intracranial aneurysm rupture risk assessment.

    Science.gov (United States)

    Xiang, J; Tutino, V M; Snyder, K V; Meng, H

    2014-10-01

    Image-based computational fluid dynamics holds a prominent position in the evaluation of intracranial aneurysms, especially as a promising tool to stratify rupture risk. Current computational fluid dynamics findings correlating both high and low wall shear stress with intracranial aneurysm growth and rupture puzzle researchers and clinicians alike. These conflicting findings may stem from inconsistent parameter definitions, small datasets, and intrinsic complexities in intracranial aneurysm growth and rupture. In Part 1 of this 2-part review, we proposed a unifying hypothesis: both high and low wall shear stress drive intracranial aneurysm growth and rupture through mural cell-mediated and inflammatory cell-mediated destructive remodeling pathways, respectively. In the present report, Part 2, we delineate different wall shear stress parameter definitions and survey recent computational fluid dynamics studies, in light of this mechanistic heterogeneity. In the future, we expect that larger datasets, better analyses, and increased understanding of hemodynamic-biologic mechanisms will lead to more accurate predictive models for intracranial aneurysm risk assessment from computational fluid dynamics. © 2014 by American Journal of Neuroradiology.

  6. Migraine prevalence in patients with unruptured intracranial aneurysms: A case-control study

    NARCIS (Netherlands)

    Witvoet, Elbert H.; Pelzer, Nadine; Terwindt, Gisela M.; Rinkel, Gabriel J. E.; Vlak, Monique H M; Algra, Ale; Wermer, Marieke J H

    Objectives Migraine is a suggested risk factor for aneurysmal subarachnoid hemorrhage (aSAH). An increased risk of aSAH in migraineurs may be explained by an increased prevalence of unruptured intracranial aneurysms (UIA). We performed a case–control study to compare lifetime migraine prevalence in

  7. Treatment of ruptured intracranial aneurysms: implications of the ISAT on clipping versus coiling

    International Nuclear Information System (INIS)

    Berg, R. van den; Rinkel, G.J.E.; Vandertop, W.P.

    2003-01-01

    Patients with a ruptured intracranial aneurysm should be treated as soon as possible after the haemorrhage to prevent rebleeding and to allow vigorous treatment of ischemic events in case of vasospasm. The choice of treatment, endovascular or surgical, should be based on the angio-architectural aspects of the aneurysm. 3D rotational subtraction angiography will more clearly show the aneurysm morphology and will therefore help in the decision-making process. If an aneurysm is suitable for endovascular treatment ('coiling'), this should be the treatment of first choice, as has been clarified in the ISAT study. Location of the aneurysm only influences the treatment decision in aneurysms located at the basilar artery bifurcation. These aneurysms are preferably treated by endovascular means. The long-term results of endovascular and surgical treatment are still the subject of debate. For both treatment modalities, re-growth of the treated aneurysm has been described, but solid comparative data is missing. In analogy with the ISAT, referral of patients with a ruptured intracranial aneurysm should be performed as soon as possible after the haemorrhage. Preferably, this should be a hospital where neurosurgeons, interventional neuroradiologists, as well as neurologists (with expertise on medical treatment of patients with a subarachnoid haemorrhage) collaborate

  8. A clinical feature and therapeutic strategy in pituitary adenomas associated with intracranial aneurysms

    International Nuclear Information System (INIS)

    Sasagawa, Yasuo; Tachibana, Osamu; Shiraga, Shunsuke; Takata, Hisasi; Akai, Takuya; Iizuka, Hideaki

    2012-01-01

    We studied the clinical feature and treatment strategy of pituitary adenomas associated with intracranial aneurysms. Among 102 pituitary adenoma patients (mean age: 54.8 years old) who received MR angiography and/or 3D-CT angiography,seven patients (6.9%) had intracranial aneurysms. The association of an aneurysm was more common in large size adenomas (p<0.05). According to the location of the aneurysms,five patients had these in the paraclinoid portion or cavernous portion of the internal carotid artery. Using MR images,we classified the aneurysms associated with pituitary adenomas as non-adjacent,adjacent,and intra-adenoma types. In non-adjacent types,an aneurysm is located apart from the adenoma,and has less chance of exposure during transsphenoidal surgery. In adjacent types,an aneurysm is located adjacent to the adenoma,and could be exposed during transsphenoidal surgery. In intra-adenoma types,an aneurysm is encased in the adenoma. In non-adjacent type aneurysms,a resection of the pituitary adenoma can be carried out before aneurysm treatment due to the low risk of rupture during surgery. In adjacent types,a tumor resection can precede aneurysm treatment in cases of low rupture risk aneurysms and untreatable aneurysms. In intra-adenoma types,adenoma resection should come after treatment of the aneurysms. Neurosurgeons should be careful about not only the presence of aneurysms in preoperative images during transsphenoidal surgery planning,but also their locations and proximity to adenomas. Such information may be crucial in deciding the order of treatment. (author)

  9. Wall enhancement on high-resolution magnetic resonance imaging may predict an unsteady state of an intracranial saccular aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Peng; Zhang, Hong-Qi [Capital Medical University, Department of Neurosurgery, Xuanwu Hospital, Beijing (China); Yang, Qi [Capital Medical University, Department of Radiology, Xuanwu Hospital, Beijing (China); Wang, Dan-Dan [Capital Medical University, Department of Clinical Pathology, Xuanwu Hospital, Beijing (China); Guan, Shao-Chen [Capital Medical University, Department of Evidence-Based Medicine, Xuanwu Hospital, Beijing (China)

    2016-10-15

    The aneurysm wall has been reported to play a critical role in the formation, development, and even rupture of an aneurysm. We used high-resolution magnetic resonance imaging (HRMRI) to investigate the aneurysm wall in an effort to identify evidence of inflammation invasion and define its relationship with aneurysm behavior. Patients with intracranial aneurysms who were prospectively evaluated using HRMRI between July 2013 and June 2014 were enrolled in this study. The aneurysm's wall enhancement and evidence of inflammation invasion were determined. In addition, the relationship between aneurysm wall enhancement and aneurysm size and symptoms, including ruptured aneurysms, giant unruptured intracranial aneurysms (UIAs) presenting as mass effect, progressively growing aneurysms, and aneurysms associated with neurological symptoms, was statistically analyzed. Twenty-five patients with 30 aneurysms were available for the current study. Fourteen aneurysms showed wall enhancement, including 6 ruptured and 8 unruptured aneurysms. Evidence of inflammation was identified directly through histological studies and indirectly through intraoperative investigations and clinical courses. The statistical analysis indicated no significant correlation between aneurysm wall enhancement and aneurysm size. However, there was a strong correlation between wall enhancement and aneurysm symptoms, with a kappa value of 0.86 (95 % CI 0.68-1). Aneurysm wall enhancement on HRMRI might be a sign of inflammatory change. Symptomatic aneurysms exhibited wall enhancement on HRMRI. Wall enhancement had a high consistent correlation of symptomatic aneurysms. Therefore, wall enhancement on HRMRI might predict an unsteady state of an intracranial saccular aneurysm. (orig.)

  10. New decision analytical models for management of intracranial aneurysms

    NARCIS (Netherlands)

    Koffijberg, H.

    2008-01-01

    This thesis addresses decision analysis, cost-effectiveness models and the analysis of heterogeneity, applied to intracranial aneurysms and subarachnoid hemorrhage (SAH). Subarachnoid hemorrhage is a subset of stroke that usually occurs at relatively young age and has poor prognosis. Although, the

  11. Initial experience with 3T 3D-TOF MRA in the diagnosis of intracranial aneurysms

    International Nuclear Information System (INIS)

    Senba, Yoshiki; Takahashi, Shizue; Matsubara, Ichiro; Sadamoto, Kazuhiko; Miki, Hitoshi; Mochizuki, Teruhito

    2006-01-01

    We assessed the value of 3T 3D-time of flight (TOF) MR angiography (MRA) in the diagnosis of intracranial aneurysms compared with 1.5T 3D-TOF MRA. Twenty-one patients with 22 aneurysms underwent MRA at 1.5T and 3T. Images were interpreted by two radiologists. Each of nine aneurysms that had been considered ''definite'' at 1.5T 3D-TOF MRA were considered ''definite'' at 3T 3D-TOF MRA. Seven aneurysms that had been considered ''suspicious'' at 1.5T MRA were considered ''definite'' at 3T. And four aneurysms that had been considered ''suspicious'' at 1.5T were considered ''negative'' at 3T. We concluded that 3T 3D-TOF MRA is superior to 1.5T 3D-TOF MRA in the diagnosis of intracranial aneurysms. (author)

  12. Ruptured intracranial aneurysm in patients with osteogenesis imperfecta: 2 familial cases and a systematic review of the literature.

    Science.gov (United States)

    Gaberel, T; Rochey, A; di Palma, C; Lucas, F; Touze, E; Emery, E

    2016-12-01

    Osteogenesis imperfecta is an inherited connective tissue disorder that causes bone fragility. Vascular complications have been described, but only few cases of ruptured intracranial aneurysm have been reported. We first described 2 familial cases of ruptured intracranial aneurysm and then conducted a systematic review of the literature. A mother and her daughter with a typical history of osteogenesis imperfecta presented with subarachnoid hemorrhage, which was related to a posterior communicating artery aneurysm in both cases. The mother had early rebleeding and died. The aneurysm was excluded by coiling in the daughter. Despite occurrence of hydrocephalus and delayed cerebral ischemia, she had an excellent functional outcome. A systematic review of the literature identified seven additional cases. None of the cases were in fact familial. All patients had a previous medical history of multiple fractures. Seven aneurysms were resolved, three by surgical clipping and four by endovascular procedure. No periprocedural complication was reported. One patient died prematurely and 6 experienced good functional outcome. We report the first familial cases of aneurysmal subarachnoid hemorrhage in osteogenesis imperfecta patients. Intracranial aneurysms are probably linked to a collagen pathology, which is at the origin of osteogenesis imperfecta. In cases of aneurysmal subarachnoid hemorrhage in an osteogenesis imperfecta family, intracranial aneurysm screenings in the relatives showing osteogenesis imperfecta should be considered. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. Surgical management of recurrent intracranial aneurysms after embolization

    Directory of Open Access Journals (Sweden)

    Hua-wei WANG

    2015-03-01

    Full Text Available Background Endovascular therapy is the first treatment choice for intracranial aneurysms currently, but it has a high recurrence rate. Some patients require surgical clipping because of the difficulty of re-embolization. This study retrospectively analyzed the clinical data of 11 cases who underwent clipping operation because of the recurrence after endovascular therapy. Combining with domestic and foreign related literatures, this paper discusses the principles and techniques of surgical treatment for recurrent aneurysms.  Methods There were a total of 11 patients with 12 recurrent aneurysms after embolization, including 3 anterior communicating artery (ACoA aneurysms, 3 middle cerebral artery (MCA aneurysms, 2 posterior communicating artery (PCoA aneurysms, one anterior cerebral artery (ACA aneurysm, one vertebral artery (VA aneurysm, one basilar tip aneurysm and one superior cerebellar artery (SCA aneurysm. There were 7 small aneurysms and 4 large aneurysms. All patients underwent surgical clipping under microscope. After operation, 11 aneurysms were complete clipped, and one was proximally blocked. The coils were reserved in 7 aneurysms, and were removed or partially removed in 5 aneurysms.  Results All patients were followed up for an average of 22 months after surgery. There were 9 cases (9/11 with the Glasgow Outcome Scale (GOS score improved or remaining unchanged compared with preoperation. One of them presented left limb weakness after operation, with the muscle strength Grade 3, while recovered to Grade 4-5 on discharge. The other 2 patients died after surgery. One case had a critical condition before surgery, and the other was secondary to thrombosis and pneumonia. Both of them had a GOS score of 2 when discharged, and died after discharge.  Conclusions There is high surgical difficulty in recurrent aneurysms, however, with adequate preoperative evaluation and surgical design, it can still promise safe and effective results

  14. Prevention and management of the complications during embolizing intracranial aneurysm with GDC

    International Nuclear Information System (INIS)

    Zhong Ming; Tan Xianxi; Wang Junlu; Hu Wenhao; Fan Lianghao

    2002-01-01

    Objective: To sum up the experience of embolization of intracranial aneurysm with Guglielmi detachable coil (GDC) and to discuss how to prevent and manage the complications during the endovascular treatment. Methods: 108 patients with intracranial aneurysm were embolized with GDC. 24 accident out of 20 patients during embolization were reviewed. Results: Among the 24 accidents, there were 10 aneurysm rupture, 5 over- embolization 5 coils end protruding to parent artery, and 4 thrombosis. Once the aneurysm ruptures, neutralizing heparin and continuing embolization was administered. Among 10 cases of aneurysm ruptures, 4 were death, 1 was severe deformity, 1 was mild deformity. Thrombolysis, heparinisation and raising blood pressure were used to control over-embolization, coil protrusion, and thrombosis. Among 5 cases of over-embolization, 1 died, 4 recovered. Among 5 cases of coils end protruding, 1 was severe deformity, 1 was mild deformity. Among 4 cases of embolization, 1 died, 1 was led sensory aphasics. The accidents resulted in 5 deaths (4.6%), 4 permanent neurological deficits (3.7%). Conclusion: The correct management of the complications during the treatment, the better understanding of the aneurysm and its parent artery angio-anatomy and the improved skill of embolizing technique are helpful to reduce the accidents and increase the cure rate

  15. Angiographic CT with intravenous contrast agent application for monitoring of intracranial flow diverting stents

    International Nuclear Information System (INIS)

    Saake, Marc; Struffert, Tobias; Goelitz, Philipp; Ott, Sabine; Doerfler, Arnd; Seifert, Frank; Ganslandt, Oliver

    2012-01-01

    Intracranial flow diverting devices are increasingly used to treat cerebral aneurysms. A reliable, non-invasive follow-up modality would be desirable. Our aim was to compare intra-arterial digital subtraction angiography (ia DSA) to angiographic computed tomography with intravenous contrast agent application (iv ACT) in the visualisation of flow diverting devices and aneurysm lumina. Follow-up monitoring by iv ACT (n = 36) and ia DSA (n = 25) in 14 patients treated with flow diverting devices for intracranial aneurysms was evaluated retrospectively. Images were evaluated by two neuroradiologists in anonymous consensus reading regarding the device deployment, wall apposition, neck coverage of the aneurysm, opacification of the vessel and device lumen, as well as the degree of aneurysm occlusion. Corresponding ia DSA and iv ACT images were scored identically in all patients regarding the stent deployment, wall apposition and neck coverage, as well as the degree of aneurysm occlusion and patency status of the device and parent artery. Opacification of the parent vessel lumen and perfused parts of the aneurysm was considered slightly inferior for iv ACT in comparison with ia DSA (seven of 36 cases), without impact on diagnosis. We demonstrated the feasibility and diagnostic value of iv ACT in follow-up imaging of intracranial flow diverting devices. Due to its high spatial resolution and non-invasive character, this novel technique might become a valuable imaging modality in these patients. (orig.)

  16. The New Low-Profile WEB 17 System for Treatment of Intracranial Aneurysms: First Clinical Experiences.

    Science.gov (United States)

    van Rooij, S B T; Peluso, J P; Sluzewski, M; Kortman, H G; van Rooij, W J

    2018-05-01

    The Woven EndoBridge (WEB) is an intrasaccular flow diverter intended to treat wide-neck aneurysms. The latest generation WEBs needed a 0.021-inch microcatheter in the small sizes. Recently, a lower profile range of WEBs compliant with a 0.017-inch microcatheter (WEB 17) has been introduced. We present the first clinical results of treatment of both ruptured and unruptured aneurysms with the WEB 17. Between December 2016 and September 2017, forty-six aneurysms in 40 patients were treated with the WEB 17. No supporting stents or balloons were used. Twenty-five aneurysms were ruptured (54%). There were 6 men and 34 women (mean age, 62 years; median, 63 years; range, 46-87 years). The mean aneurysm size was 4.9 mm (median, 5 mm; range, 2-7 mm). There were 2 thromboembolic procedural complications without clinical sequelae and no ruptures. The overall permanent procedural complication rate was 0% (0 of 40; 97.5% CI, 0%-10.4%). Imaging follow-up at 3 months was available in 33 patients with 39 aneurysms (97.5% of 40 eligible aneurysms). In 1 aneurysm, the detached WEB was undersized and the remnant was additionally treated with coils after 1 week. This same aneurysm reopened at 3 months and was again treated with a second WEB. One other aneurysm showed persistent WEB filling at 3 months. Complete occlusion was achieved in 28 of 39 aneurysms (72%), and 9 aneurysms (23%) showed a neck remnant. The WEB 17 is safe and effective for both ruptured and unruptured aneurysms. The WEB 17 is a valuable addition to the existing WEB size range, especially for very small aneurysms. © 2018 by American Journal of Neuroradiology.

  17. Comparison of 16-row multislice CT angiography with conventional angiography for detection and evaluation of intracranial aneurysms

    International Nuclear Information System (INIS)

    Donmez, Halil; Serifov, Elman; Kahriman, Guven; Mavili, Ertugrul; Durak, Ahmet Candan; Menkue, Ahmet

    2011-01-01

    Purpose: The aim of this study is to compare the diagnostic performance of 16-row computed tomographic angiography (MDCTA) with digital subtraction angiography (DSA) for the detection and characterization of intracranial aneurysms in patients with nontraumatic subarachnoid hemorrhages (SAH). Materials and methods: One-hundred and twelve consecutive patients with suspected intracranial aneurysm underwent both 16-row MDCTA and DSA. The MDCT angiograms were interpreted in a blinded fashion by using combination with VRI, MIP and MPR techniques. Sensitivity specificity and accuracy were calculated for the CTA and DSA. The results were compared with each other. The DSA reader's interpretation was accepted as the reference standard. Results: A total of 164 aneurysms were detected at DSA in 112 patients, no aneurysms were detected by DSA and MDCTA in 16 patients. Eight aneurysms were missed by MDCTA. The overall sensitivity, specificity, and accuracy of MDCTA on a per-aneurysm basis were 95.1%, 94.1%, and 95%, respectively. According to the size of the aneurysm less than 3 mm; sensitivity, specificity and diagnostic accuracy of MDCTA were 86.1%, 94.1%, 88.6%, respectively. Conclusion: This study suggests that MDCTA is equally as sensitive as DSA in the detection of intracranial aneurysms of greater than 3 mm, and it also reveals 100% detection rate for ruptured aneurysms.

  18. Stent-Assisted Coil Embolization of a Mycotic Renal Artery Aneurysm by Use of a Self-Expanding Neurointerventional Stent

    International Nuclear Information System (INIS)

    Rabellino, Martin; García-Nielsen, Luis; Zander, Tobias; Baldi, Sebastián; Llorens, Rafael; Maynar, Manuel

    2011-01-01

    Mycotic aneurysms are uncommon, especially those located in visceral arteries. We present a case of a patient with two visceral mycotic aneurysms due to bacterial endocarditis, one located in right upper pole renal artery and the second in the splenic artery. Both aneurysms were treated as endovascular embolization using microcoils. In the aneurysm located at the renal artery, the technique of stent-assisted coils embolization was preferred to avoid coils migration due to its wide neck. The stent used was the Solitaire AB, which was designed for the treatment of intracranial aneurysms and was used recently in acute stroke as a mechanical thrombectomy device. Complete embolization of the aneurysm was achieved, preserving all the arterial branches without nephrogram defects in the final angiogram.

  19. Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents

    Energy Technology Data Exchange (ETDEWEB)

    Lubicz, Boris [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Hopital Erasme, Service de Radiologie (EA 2691), Brussels (Belgium); Collignon, Laurent; Baleriaux, Danielle [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Lefranc, Florence; Bruneau, Michael; Brotchi, Jacques; Witte, Olivier de [Erasme University Hospital, Department of Neurosurgery, Brussels (Belgium)

    2008-06-15

    We report our experience with endovascular treatment (EVT) of circumferential and fusiform intracranial aneurysms by a reconstructive approach with self-expandable stents. A retrospective review of our prospectively maintained database identified all circumferential and fusiform aneurysms treated by a reconstructive endovascular approach over a 3-year period. Clinical charts, procedural data, and angiographic results were reviewed. From April 2004 to May 2007, 13 patients were identified, of whom 12 were asymptomatic and 1 presented with a subarachnoid hemorrhage. Two patients with an aneurysm {<=}2 mm were treated by stent-within-stent placement without coiling (group 1). In 11 patients with a larger aneurysm, stenting with subsequent coiling was performed (group 2). In this latter approach, a balloon was temporarily inflated within the stent to ensure safe coil delivery. All patients showed an excellent clinical outcome. Asymptomatic procedural complications occurred in three patients, two with cervical internal carotid artery dissection and one with retroperitoneal hematoma. In patients of group 1, the aneurysm had completely disappeared at 6 months. In patients of group 2, aneurysm occlusion was complete in three and incomplete in eight. Follow-up angiography in 12 patients showed four with further thrombosis, six with stable results, and two with minor recanalization. Circumferential and fusiform intracranial aneurysms may be treated by a reconstructive endovascular approach with self-expandable stents. In small aneurysms, a stent-within-stent technique is effective, whereas stenting and subsequent coiling is indicated in larger aneurysms. This therapeutic protocol is associated with good clinical and anatomical results. (orig.)

  20. Comparison of devices used for stent-assisted coiling of intracranial aneurysms.

    Directory of Open Access Journals (Sweden)

    Benjamin Izar

    Full Text Available INTRODUCTION: Two self-expandable stents, the Neuroform and the Enterprise stent, are widely used for stent-assisted coiling (SAC of complex shaped intracranial aneurysms. However, comparative knowledge about technical feasibility, peri- and post-procedural morbidity and mortality, packing densities as well as follow-up data is limited. MATERIAL AND METHODS: We conducted a retrospective study to investigate differences in aneurysms stented with the Enterprise or Neuroform stents. Angiographic follow-up (mean 19.42 months was available in 72.6% (61/84 of aneurysms treated with stent-assisted coiling. We further sought to compare stent-assisted coiling to a matched patient population with aneurysms treated by conventional coil embolization. RESULTS: The stenting success rate of the Enterprise was higher compared to the Neuroform stent (46/48 and 42/51, respectively. In 5 of 9 cases in which the Neuroform stent was not navigable to the landing zone, we successfully deployed an Enterprise stent instead. Eventually, 42 aneurysms were coiled after stenting in each group. We observed no significant differences in peri-procedural complication rate, post-procedural hospital stay, packing density, recurrence rate or number of in-stent stenosis. Strikingly, 36.1% of followed aneurysms in the SAC group showed progressive occlusion on angiographic follow-up imaging. The packing density was significantly higher in aneurysms treated by SAC as compared to conventionally coiled aneurysms, while recanalization rate was significantly lower in the SAC group. CONCLUSION: The procedural success rate is higher using the Enterprise, but otherwise both stents exhibited similar characteristics. Lower recurrence frequency and complication rates comparable to conventional coil embolization emphasize the importance of stent-assisted coiling in the treatment of complex aneurysms. Progressive occlusion on angiographic follow-up was a distinct and frequent observation in the

  1. Detection and characterization of intracranial aneurysms: magnetic resonance angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Shahzad, R.; Younas, F.

    2011-01-01

    Objective: To compare magnetic resonance angiography (MRA) with Intra-arterial digital subtraction angiography (IA-DSA) in detection and characterization of intracranial aneurysms. Study Design: Comparative cross-sectional study. Place and Duration of Study: Department of Diagnostic Imaging, Lahore General Hospital, Lahore, from January to June 2007. Methodology: Thirty patients presented with aneurysmal subarachnoid haemorrhage (SAH) and focal neurological signs were selected by convenience sampling. Three dimensional time of flight (3D TOF) MRA using maximum intensity projection (MIP) was performed on all patients along with DSA. Results of 3D TOF MRA were compared with those of IA-DSA taking IA-DSA as Gold standard. Results: Out of 30 patients 14 (46.7%) were males and 16 (53.3%) were females with mean age of 41+-14.1 years. MRA detected 29 out of 30 aneurysmal lesions with sensitivity of 96.7%. Regarding characterization of aneurysms results of MRA were comparable to those of IA-DSA. Conclusion: 3D TOF MRA technique showed a high sensitivity in this study. This technique can be used as a non-invasive screening test for intracranial aneurysms and as a suitable alternative primary examination to IA-DSA prior to aneurysmal surgery. (author)

  2. Application of virtual reality techniques in preoperative surgical planning for intracranial anterior circulation aneurysms

    Directory of Open Access Journals (Sweden)

    Shou-sen WANG

    2012-05-01

    Full Text Available Objective  To investigate the value of virtual reality (VR technique in the surgical planning for anterior circulation aneurysms of Willis circle. Methods  A total of 50 patients with 57 aneurysms confirmed by CT angiography in the anterior circle of Willis were enrolled in this study. In preoperative Hunt-Hess scale, grade Ⅰ was designated in 7 patients, grade Ⅱ in 22, grade Ⅲ in 17, grade Ⅳ in 3, grade Ⅴ in 1 patient. Among the aneurysms, 16 were small (≤5mm in diameter, 28 medium (5-15mm, 10 large (15-25mm and 3 giant (≥25mm in size. The thin-slice head scanning data were achieved by 64-slice spiral CT machine. These data was then transferred into Dextroscope image workstation. The virtual imaging system generated clear and vivid virtual images. We compared the findings between simulation surgical operation and actual operation. Results  VR system make the operator felt "personally on the scene" and was able to communicate with the imaging. It could not only visually display the anatomical structures in three dimensions, but also could simulate some surgical procedures, which basically simulated the same outcome of actual operation. All the 50 patients were successfully treated by microsurgical clipping of main aneurysmal or contributory aneurysmal necks. Conclusions  The surgeons is able to be more confident, and the identification for the complex vascular abnormality is improved by planning operative procedure in virtual-reality environment. The virtual-reality system makes the actual operative procedure more concise, thus it is of positive value in surgery for intracranial aneurysm.

  3. Intracranial aneurysm and arachnoid cyst: just a coincidence? A case report.

    Science.gov (United States)

    Aguiar, Guilherme Brasileiro de; Santos, Rafael Gomes Dos; Paiva, Aline Lariessy Campos; Silva, João Miguel de Almeida; Silva, Rafael Carlos da; Veiga, José Carlos Esteves

    2017-12-18

    Presence of an arachnoid cyst and a non-ruptured intracystic brain aneurysm is extremely rare. The aim of this paper was to describe a case of a patient with an arachnoid cyst and a non-ruptured aneurysm inside it. Clinical, surgical and radiological data were analyzed and the literature was reviewed. A patient complained of chronic headache. She was diagnosed as having a temporal arachnoid cyst and a non-ruptured middle cerebral artery aneurysm inside it. Surgery was performed to clip the aneurysm and fenestrate the cyst. This report raises awareness about the importance of intracranial vascular investigation in patients with arachnoid cysts and brain hemorrhage.

  4. The same sequence variant on 9p21 associates with myocardial infarction, abdominal aortic aneurysm and intracranial aneurysm

    DEFF Research Database (Denmark)

    Helgadottir, Anna; Thorleifsson, Gudmar; Magnusson, Kristinn P

    2008-01-01

    . Here we report that rs10757278-G is associated with, in addition to CAD, abdominal aortic aneurysm (AAA; odds ratio (OR) = 1.31, P = 1.2 x 10(-12)) and intracranial aneurysm (OR = 1.29, P = 2.5 x 10(-6)), but not with T2D. This variant is the first to be described that affects the risk of AAA...

  5. The effect of inlet waveforms on computational hemodynamics of patient-specific intracranial aneurysms.

    Science.gov (United States)

    Xiang, J; Siddiqui, A H; Meng, H

    2014-12-18

    Due to the lack of patient-specific inlet flow waveform measurements, most computational fluid dynamics (CFD) simulations of intracranial aneurysms usually employ waveforms that are not patient-specific as inlet boundary conditions for the computational model. The current study examined how this assumption affects the predicted hemodynamics in patient-specific aneurysm geometries. We examined wall shear stress (WSS) and oscillatory shear index (OSI), the two most widely studied hemodynamic quantities that have been shown to predict aneurysm rupture, as well as maximal WSS (MWSS), energy loss (EL) and pressure loss coefficient (PLc). Sixteen pulsatile CFD simulations were carried out on four typical saccular aneurysms using 4 different waveforms and an identical inflow rate as inlet boundary conditions. Our results demonstrated that under the same mean inflow rate, different waveforms produced almost identical WSS distributions and WSS magnitudes, similar OSI distributions but drastically different OSI magnitudes. The OSI magnitude is correlated with the pulsatility index of the waveform. Furthermore, there is a linear relationship between aneurysm-averaged OSI values calculated from one waveform and those calculated from another waveform. In addition, different waveforms produced similar MWSS, EL and PLc in each aneurysm. In conclusion, inlet waveform has minimal effects on WSS, OSI distribution, MWSS, EL and PLc and a strong effect on OSI magnitude, but aneurysm-averaged OSI from different waveforms has a strong linear correlation with each other across different aneurysms, indicating that for the same aneurysm cohort, different waveforms can consistently stratify (rank) OSI of aneurysms. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Treatment of intracranial aneurysms. Reconstruction of the parent artery with flow-diverting (Silk) stent

    DEFF Research Database (Denmark)

    Wagner, Aase; Cortsen, Marie; Hauerberg, John

    2011-01-01

    the periprocedural complications, immediate result, late complications, imaging follow-up at 6 and 12 months and clinical follow-up at 2-23 months. METHODS: Twenty-two patients with 26 wide-necked or blister-like aneurysms had 23 treatments with implantation of a Silk stent. Eleven patients had re...... (86%) were occluded. CONCLUSION: The effect of the Silk FD in terms of occlusion of the aneurysms seems to occur mainly during the first 6 months after placement but continues during the following time. Most delayed complications occur immediately after discontinuing the anticoagulation medication...

  7. Vortex dynamics in ruptured and unruptured intracranial aneurysms

    Science.gov (United States)

    Trylesinski, Gabriel

    Intracranial aneurysms (IAs) are a potentially devastating pathological dilation of brain arteries that affect 1.5-5 % of the population. Causing around 500 000 deaths per year worldwide, their detection and treatment to prevent rupture is critical. Multiple recent studies have tried to find a hemodynamics predictor of aneurysm rupture, but concluded with distinct opposite trends using Wall Shear Stress (WSS) based parameters in different clinical datasets. Nevertheless, several research groups tend to converge for now on the fact that the flow patterns and flow dynamics of the ruptured aneurysms are complex and unstable. Following this idea, we investigated the vortex properties of both unruptured and ruptured cerebral aneurysms. A brief comparison of two Eulerian vortex visualization methods (Q-criterion and lambda 2 method) showed that these approaches gave similar results in our complex aneurysm geometries. We were then able to apply either one of them to a large dataset of 74 patient specific cases of intracranial aneurysms. Those real cases were obtained by 3D angiography, numerical reconstruction of the geometry, and then pulsatile CFD simulation before post-processing with the mentioned vortex visualization tools. First we tested the two Eulerian methods on a few cases to verify their implementation we made as well as compare them with each other. After that, the Q-criterion was selected as method of choice for its more obvious physical meaning (it shows the balance between two characteristics of the flow, its swirling and deformation). Using iso-surfaces of Q, we started by categorizing the patient-specific aneurysms based on the gross topology of the aneurysmal vortices. This approach being unfruitful, we found a new vortex-based characteristic property of ruptured aneurysms to stratify the rupture risk of IAs that we called the Wall-Kissing Vortices, or WKV. We observed that most ruptured aneurysms had a large amount of WKV, which appears to agree with

  8. Multiple intracranial aneurysms and moyamoya disease associated with microcephalic osteodysplastic primordial dwarfism type II: surgical considerations.

    Science.gov (United States)

    Waldron, James S; Hetts, Steven W; Armstrong-Wells, Jennifer; Dowd, Christopher F; Fullerton, Heather J; Gupta, Nalin; Lawton, Michael T

    2009-11-01

    Microcephalic osteodysplastic primordial dwarfism type II (MOPD II) is a rare genetic syndrome characterized by extremely small stature and microcephaly, and is associated in 25% of patients with intracranial aneurysms and moyamoya disease. Although aneurysmal subarachnoid hemorrhage and stroke are leading causes of morbidity and death in these patients, MOPD II is rarely examined in the neurosurgical literature. The authors report their experience with 3 patients who presented with MOPD II, which includes a patient with 8 aneurysms (the most aneurysms reported in the literature), and the first report of a patient with both moyamoya disease and multiple aneurysms. The poor natural history of these lesions indicates aggressive microsurgical and/or endovascular therapy. Microsurgery, whether for aneurysm clip placement or extracranial-intracranial bypass, is challenging due to tight surgical corridors and diminutive arteries in these patients, but is technically feasible and strongly indicated when multiple aneurysms must be treated or cerebral revascularization is needed.

  9. Changes of incompletely embolized aneurysm with tungsten coils : an experimental study in dogs

    International Nuclear Information System (INIS)

    Yu, In Kyu; Han, Moon Hee; Kim, Sung Hyun; Won, Hyung Jin; Chang, Kee Hyun; Yeon, Kyung Mo; Choe, Ghee Young; Kim, Sam Soo

    1999-01-01

    To evaluate changes of residual aneurysms according to the size of aneurysmal neck and thrombogenicity of a tungsten coil after incomplete embolization of experimental lateral aneurysms. Eleven experimental lateral aneurysms with different aneurysmal neck size were created in the common carotid arteries of mongrel dogs. They were then divided into narrow-neck(n=3), wide-neck(n=6) and spontaneously thrombosed control(n=2) groups. After confirmation of aneurysmal patency, incomplete embolizations of varying degrees (about 30% to near total occlusion) were performed using 5mm-diameter tungsten coils. Angiography was performed immediately before and after, and one and six weeks after embolizations. The size of residual aneurysm was measured on each angiogram. After the last angiography embolized aneurysms were excised and examined under light and electron microscopes. On angiograms obtained 6 weeks after embolization, all residual narrow neck aneurysms were completely occluded, whereas in those with a wide-neck, therre was either no change (n=4) or a slight increase in size(n=2). On light microscopy, all narrow-neck aneurysms showed total organized fibrosis while all control aneurysms and half those with a wide neck showed unorganized thrombi. The embolized group showed a higher degree of organization in the aneurysmal cavity than did the control group. Neointima formation was seen in all embolized aneurysms, but no aneurysm showed foreign body reaction. On electron microscopy, uniform thickness of plasma coatings was noted on the surface of the tungsten coils. A wide-neck residual aneurysm may persist or increase in size, while one with a narrow-neck can be thrombosed after incomplete embolization with tungsten coils in a lateral aneurym. Careful consideration might be necessary in the embolization of wide-neck aneurysms. With plasma coatings on its surface and organized fibrosis, tungsten coil can be an useful for embolization of an aneurysm

  10. Unruptured Intracranial Aneurysms. A Critical Review of the International Study of Unruptured Intracranial Aneurysms (ISUIA) and of Appropriate Methods to Address the Clinical Problem.

    Science.gov (United States)

    Raymond, J; Guillemin, F; Proust, F; Molyneux, A J; Fox, A J; Claiborne, J S; Meder, J F; Rouleau, I

    2008-03-30

    The preventive treatment of unruptured aneurysms has been performed for decades despite the lack of evidence of a clinical benefit. Reports of observational studies such as the International Study of Unruptured Intracranial Aneurysms (ISUIA) suggest that preventive treatments are rarely justified. Are these reports compelling enough to guide clinical practice? The ISUIA methods and data are reviewed and analysed in a more conventional manner. The design of the appropriate clinical research program is approached by steps, reviewing potential problems, from the formulation of the precise research question to the interpretation of subgroup analyses, including sample size, representativity, duration of observation period, blinding, definition of outcome events, analysis of cross-overs, losses to follow-up, and data reporting. Unruptured intracranial aneurysms observed in ISUIA ruptured at a minimal annual rate of 0.8% (0.5-1%), despite multiple methodological difficulties biased in favour of a benign natural history. Available registries do not have the power or the design capable of providing normative guidelines for clinical decisions. The appropriate method to solve the clinical dilemma is a multicentric trial comparing the incidence of a hard clinical outcome events in approximately 2000 patients randomly allocated to a treatment group and a deferred treatment group, all followed for ten years or more. Observational studies have failed to provide reliable evidence in favour or against the preventive treatment of unruptured aneurysms. A randomized trial is in order to clarify what is the role of prevention in this common clinical problem.

  11. The influence of neck thrombus on clinical outcome and aneurysm morphology after endovascular aneurysm repair

    NARCIS (Netherlands)

    F.M.V. Bastos Gonçalves (Frederico); H.J.M. Verhagen (Hence); K. Chinsakchai (Khamin); J.W. van Keulen (Jasper); M.T. Voûte (Michiel); H.J.A. Zandvoort (Herman); F.L. Moll (Frans); J.A. van Herwaarden (Joost)

    2012-01-01

    textabstractObjective: This study investigated the influence of significant aneurysm neck thrombus in clinical and morphologic outcomes after endovascular aneurysm repair (EVAR). Methods: The patient population was derived from a prospective EVAR database from two university institutions in The

  12. In vivo hemodynamic analysis of intracranial aneurysms obtained by magnetic resonance fluid dynamics (MRFD) based on time-resolved three-dimensional phase-contrast MRI

    International Nuclear Information System (INIS)

    Isoda, Haruo; Takeda, Hiroyasu; Yamashita, Shuhei; Takehara, Yasuo; Sakahara, Harumi; Ohkura, Yasuhide; Kosugi, Takashi; Hirano, Masaya; Hiramatsu, Hisaya; Namba, Hiroki; Alley, Marcus T.; Bammer, Roland; Pelc, Norbert J.

    2010-01-01

    Hemodynamics is thought to play a very important role in the initiation, growth, and rupture of intracranial aneurysms. The purpose of our study was to perform in vivo hemodynamic analysis of unruptured intracranial aneurysms of magnetic resonance fluid dynamics using time-resolved three-dimensional phase-contrast MRI (4D-Flow) at 1.5 T and to analyze relationships between hemodynamics and wall shear stress (WSS) and oscillatory shear index (OSI). This study included nine subjects with 14 unruptured aneurysms. 4D-Flow was performed by a 1.5-T magnetic resonance scanner with a head coil. We calculated in vivo streamlines, WSS, and OSI of intracranial aneurysms based on 4D-Flow with our software. We evaluated the number of spiral flows in the aneurysms and compared the differences in WSS or OSI between the vessel and aneurysm and between whole aneurysm and the apex of the spiral flow. 3D streamlines, WSS, and OSI distribution maps in arbitrary direction during the cardiac phase were obtained for all intracranial aneurysms. Twelve aneurysms had one spiral flow each, and two aneurysms had two spiral flows each. The WSS was lower and the OSI was higher in the aneurysm compared to the vessel. The apex of the spiral flow had a lower WSS and higher OSI relative to the whole aneurysm. Each intracranial aneurysm in this study had at least one spiral flow. The WSS was lower and OSI was higher at the apex of the spiral flow than the whole aneurysmal wall. (orig.)

  13. In vivo hemodynamic analysis of intracranial aneurysms obtained by magnetic resonance fluid dynamics (MRFD) based on time-resolved three-dimensional phase-contrast MRI.

    Science.gov (United States)

    Isoda, Haruo; Ohkura, Yasuhide; Kosugi, Takashi; Hirano, Masaya; Takeda, Hiroyasu; Hiramatsu, Hisaya; Yamashita, Shuhei; Takehara, Yasuo; Alley, Marcus T; Bammer, Roland; Pelc, Norbert J; Namba, Hiroki; Sakahara, Harumi

    2010-10-01

    Hemodynamics is thought to play a very important role in the initiation, growth, and rupture of intracranial aneurysms. The purpose of our study was to perform in vivo hemodynamic analysis of unruptured intracranial aneurysms of magnetic resonance fluid dynamics using time-resolved three-dimensional phase-contrast MRI (4D-Flow) at 1.5 T and to analyze relationships between hemodynamics and wall shear stress (WSS) and oscillatory shear index (OSI). This study included nine subjects with 14 unruptured aneurysms. 4D-Flow was performed by a 1.5-T magnetic resonance scanner with a head coil. We calculated in vivo streamlines, WSS, and OSI of intracranial aneurysms based on 4D-Flow with our software. We evaluated the number of spiral flows in the aneurysms and compared the differences in WSS or OSI between the vessel and aneurysm and between whole aneurysm and the apex of the spiral flow. 3D streamlines, WSS, and OSI distribution maps in arbitrary direction during the cardiac phase were obtained for all intracranial aneurysms. Twelve aneurysms had one spiral flow each, and two aneurysms had two spiral flows each. The WSS was lower and the OSI was higher in the aneurysm compared to the vessel. The apex of the spiral flow had a lower WSS and higher OSI relative to the whole aneurysm. Each intracranial aneurysm in this study had at least one spiral flow. The WSS was lower and OSI was higher at the apex of the spiral flow than the whole aneurysmal wall.

  14. Morphological characteristics associated with rupture risk of multiple intracranial aneurysms.

    Science.gov (United States)

    Wang, Guang-Xian; Liu, Lan-Lan; Wen, Li; Cao, Yun-Xing; Pei, Yu-Chun; Zhang, Dong

    2017-10-01

    To identify the morphological parameters that are related to intracranial aneurysms (IAs) rupture using a case-control model. A total of 107 patients with multiple IAs and aneurysmal subarachnoid hemorrhage between August 2011 and February 2017 were enrolled in this study. Characteristics of IAs location, shape, neck width, perpendicular height, depth, maximum size, flow angle, parent vessel diameter (PVD), aspect ratio (AR) and size ratio (SR) were evaluated using CT angiography. Multiple logistic regression analysis was used to identify the independent risk factors associated with IAs rupture. Receiver operating characteristic curve analysis was performed on the final model, and the optimal thresholds were obtained. IAs located in the internal carotid artery (ICA) was associated with a negative risk of rupture, whereas AR, SR1 (height/PVD) and SR2 (depth/PVD) were associated with increased risk of rupture. When SR was calculated differently, the odds ratio values of these factors were also different. The receiver operating characteristic curve showed that AR, SR1 and SR2 had cut-off values of 1.01, 1.48 and 1.40, respectively. SR3 (maximum size/PVD) was not associated with IAs rupture. IAs located in the ICA are associated with a negative risk of rupture, while high AR (>1.01), SR1 (>1.48) or SR2 (>1.40) are risk factors for multiple IAs rupture. Copyright © 2017 Hainan Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  15. Systematic review of reviews of risk factors for intracranial aneurysms

    International Nuclear Information System (INIS)

    Clarke, Mike

    2008-01-01

    Systematic reviews of systematic reviews identify good quality reviews of earlier studies of medical conditions. This article describes a systematic review of systematic reviews performed to investigate factors that might influence the risk of rupture of an intracranial aneurysm. It exemplifies the technique of this type of research and reports the finding of a specific study. The annual incidence of subarachnoid haemorrhage resulting from the rupture of intracranial aneurysms is estimated to be nine per 100,000. A large proportion of people who have this bleed, will die or remain dependent on the care of others for some time. Reliable knowledge about the risks of subarachnoid haemorrhage in different populations will help in planning, screening and prevention strategies and in predicting the prognosis of individual patients. If the necessary data were available in the identified reviews, an estimate for the numerical relationship between a particular characteristic and the risk of subarachnoid haemorrhage was included in this report. The identification of eligible systematic reviews relied mainly on the two major bibliographic databases of the biomedical literature: PubMed and EMBASE. These were searched in 2006, using specially designed search strategies. Approximately 2,000 records were retrieved and each of these was checked carefully against the eligibility criteria for this systematic review. These criteria required that the report be a systematic review of studies assessing the risk of subarachnoid haemorrhage in patients known to have an unruptured intracranial aneurysm or of studies that had investigated the characteristics of people who experienced a subarachnoid haemorrhage without previously being known to have an unruptured aneurysm. Reports which included more than one systematic review were eligible and each of these reviews was potentially eligible. The quality of each systematic review was assessed. In this review, 16 separate reports were

  16. Perioperative Variables Contributing to the Rupture of Intracranial Aneurysm: An Update

    Directory of Open Access Journals (Sweden)

    Tumul Chowdhury

    2013-01-01

    Full Text Available Background. Perioperative aneurysm rupture (PAR is one of the most dreaded complications of intracranial aneurysms, and approximately 80% of nontraumatic SAHs are related to such PAR aneurysms. The literature is currently scant and even controversial regarding the issues of various contributory factors on different phases of perioperative period. Thus this paper highlights the current understanding of various risk factors, variables, and outcomes in relation to PAR and try to summarize the current knowledge. Method. We have performed a PubMed search (1 January 1991–31 December 2012 using search terms including “cerebral aneurysm,” “intracranial aneurysm,” and “intraoperative/perioperative rupture.” Results. Various risk factors are summarized in relation to different phases of perioperative period and their relationship with outcome is also highlighted. There exist many well-known preoperative variables which are responsible for the highest percentage of PAR. The role of other variables in the intraoperative/postoperative period is not well known; however, these factors may have important contributory roles in aneurysm rupture. Preoperative variables mainly include natural course (age, gender, and familial history as well as the pathophysiological factors (size, type, location, comorbidities, and procedure. Previously ruptured aneurysm is associated with rupture in all the phases of perioperative period. On the other hand intraoperative/postoperative variables usually depend upon anesthesia and surgery related factors. Intraoperative rupture during predissection phase is associated with poor outcome while intraoperative rupture at any step during embolization procedure imposes poor outcome. Conclusion. We have tried to create such an initial categorization but know that we cannot scale according to its clinical importance. Thorough understanding of various risk factors and other variables associated with PAR will assist in better

  17. Experimental study on blood flow patterns through the phantoms of the intracranial arterial aneurysms using color Doppler imaging

    International Nuclear Information System (INIS)

    Chung, Tae Sub; Jeong, Eun Kee; Rhim, Yoon Chul; Kim, Sung Bin; Lee, Dong Hoon; Kim, Dae In

    1994-01-01

    The occurrence, growth, thrombosis, and rupture of intracranial saccular aneurysms can be directly related to the effect of hemodynamic forces. We developed the phantom flow models and compared with the computer simulation program to analyse the flow pattern and hemodynamics that might be responsible for the intracranial arterial aneurysms. We designed the arterial phantoms of three major sites of intracranial arterial aneurysm ; 1) basilar artery tip, 2) internal carotid artery bifurcation, 3) curved area of internal carotid artery. Flow patterns in the aneurysmal portion of phantoms were evaluated with color Doppler system on the connection with automatic closed type of circulation system. Then, we compared the results with computer simulation. The hemodynamic characteristics of the phantoms were identical with those obtained by computerisation's. Three distinct zones of flow were identified by color Doppler studies on the aneurysm of the curved area of an internal carotid artery : 1) an inflow zone entering the aneurysm at the distal aspect of its orifice, 2) an outflow zone exiting the aneurysm at the proximal aspect of its orifice, 3) a central slow vortex.However, the phantoms of basilar artery tip and artery bifurcation showed a direct inflow stream at the dome of an aneurysm. Flow dynamics in the various phantoms of the aneurysms can be successfully evaluated with color Doppler imaging, and were consistent with those predicted by computer simulations

  18. Assessment of long-term effects of aneurysms trapping and extracranial-intracranial bypass surgery in patients with complex cerebral aneurysms

    Directory of Open Access Journals (Sweden)

    MAO Zhi-qi

    2012-02-01

    Full Text Available Objective To study the long-term effects of extracranial-intracranial (EC-IC bypass and aneurysms trapping in patients with complex cerebral aneurysms. Methods Seventeen patients with complex aneurysms, who underwent EC-IC bypass and aneurysms trapping from 2008 to 2009, were followed up. Clinical records were reviewed, modified Rankin Scale (mRS was recorded at admission, discharging, and follow-up point, and activities of daily living (ADL scale (Barthel Index at admission and follow-up point. Results Seventeen patients (11 males and 6 females were followed up. At admission mRS scores were 1.06 ± 0.87, Barthel index 91.10 ± 10.30. Superficial temporal artery-middle cerebral artery (STA-MCA was performed in 8 cases, extracarotid artery-great saphenous vein-middle cerebral artery (ECA-GSV-MCA in 5 cases, extracarotid artery-radial artery-middle cerebral artery (ECA-RA-MCA in 3 cases, occipital artery-posterior inferior cerebellar artery (OA-PICA in 1 case. Patients were followed up for 19-39 months (mean 28.67 months. At follow-up point, 2 patients (11.76% died, operation-related mortality was 5.88% (1/17, operation-related morbidity 5.88% (1/17, mRS scores 1.07 ± 1.16, Barthel index 96.40 ± 10.30. Conclusion Patients with complex aneurysms who were impossible to be treated with surgical clipping or endovascular intervention could be cured with extracranial-intracranial bypass and aneurysms trapping, and good follow-up results were acquired.

  19. Nursing assistance for spring coil occlusion for the treatment of intracranial giant internal carotid artery aneurysms

    International Nuclear Information System (INIS)

    Ma Yugang; Mao Yanjun; Yuan Yili; Hu Yaqin; Liu Jing; Xi Juan

    2010-01-01

    Objective: To discuss the importance of balloon occlusion test before interventional treatment of the intracranial giant internal carotid artery aneurysms and to sum up the nursing experience in assisting the procedure. Methods: Proper perioperative nursing measures were carried out for 12 patients, who suffered from intracranial giant internal carotid artery aneurysm and underwent spring coil occlusion treatment. Nursing measures included mental care, observation of the vital signs, prevention of the complications, etc. Results: Neither death nor exacerbation of the condition occurred in all the 12 patients. The patients were discharged from the hospital with a mean hospitalization of nine days. During a follow-up period ranged from 4 months to one year, seven patients had no disagreeable feeling, one patient complained of discomfort but no abnormality was found on follow-up DSA, and disappearance of the aneurysm was observed in 4 patients. Conclusion: The monitoring of the vital signs, the prevention of the complications and the standard nursing care are the key points for ensuring a successful operation in treating intracranial giant internal carotid artery aneurysms with spring coil occlusion. (authors)

  20. Distribution of ABO blood groups in the patients with intracranial aneurysm and association of different risk factors with particular blood type.

    Science.gov (United States)

    Bir, Shyamal Chandra; Bollam, Papireddy; Nanda, Anil

    2015-01-01

    The association between ABO blood groups and intracranial aneurysms is not well-known. Many co-morbid factors are associated with intracranial aneurysms. Our objective was to assess the prevalence of different blood group in patients with intracranial aneurysm and to look for associations between risk factors and these groups. This retrospective study includes 1,491 cases who underwent surgical operations for intracranial aneurysms from 1993-2014. We have evaluated the information related to clinical history, ABO blood groups and associated risk factors in the patients both ruptured and unruptured intracranial aneurysms by chart review of the cases. In our study, out of 1,491 cases, the most common ABO blood groups were group O (668 cases, 44.80%) and Group A (603 cases, 40.44%), and Rh(+) in 1,319 (88.4%) and Rh(-) in 147 (11.6%). Blood Group A (43% vs. 36%) and Group B (16.2% vs. 8.6%) were significantly higher in Caucasian and African Americans respectively. However, in general population, there was no significant difference in blood groups between Caucasians and African Americans. Rh(-) factor was significantly higher in Caucasians compared to African Americans. Incidence of smoking was significantly higher in aneurysm patients with O group compared to others. In addition, incidence of hypercholesterolemia was significantly higher in aneurysm patients with A group compared to others. The racial disparity in the distribution of blood groups, and risk factor association with blood groups in the development of intracranial aneurysm needs to be considered. The findings from our study may be useful in identifying patients at increased risk. Further study may be required to establish the risks from multiple centers studies around the world.

  1. Particle imaging velocimetry evaluation of intracranial stents in sidewall aneurysm: hemodynamic transition related to the stent design.

    Science.gov (United States)

    Bouillot, Pierre; Brina, Olivier; Ouared, Rafik; Lovblad, Karl-Olof; Farhat, Mohamed; Pereira, Vitor Mendes

    2014-01-01

    We investigated the flow modifications induced by a large panel of commercial-off-the-shelf (COTS) intracranial stents in an idealized sidewall intracranial aneurysm (IA). Flow velocities in IA silicone model were assessed with and without stent implantation using particle imaging velocimetry (PIV). The use of the recently developed multi-time-lag method has allowed for uniform and precise measurements of both high and low velocities at IA neck and dome, respectively. Flow modification analysis of both regular (RSs) and flow diverter stents (FDSs) was subsequently correlated with relevant geometrical stent parameters. Flow reduction was found to be highly sensitive to stent porosity variations for regular stents RSs and moderately sensitive for FDSs. Consequently, two distinct IA flow change trends, with velocity reductions up to 50% and 90%, were identified for high-porosity RS and low-porosity FDS, respectively. The intermediate porosity (88%) regular braided stent provided the limit at which the transition in flow change trend occurred with a flow reduction of 84%. This transition occurred with decreasing stent porosity, as the driving force in IA neck changed from shear stress to differential pressure. Therefore, these results suggest that stents with intermediate porosities could possibly provide similar flow change patterns to FDS, favourable to curative thrombogenesis in IAs.

  2. Genetic risk load according to the site of intracranial aneurysms

    NARCIS (Netherlands)

    van 't Hof, Femke N. G.; Kurki, Mitja I.; Kleinloog, Rachel; de Bakker, Paul I. W.; von Und Zu Fraunberg, Mikael; Jääskeläinen, Juha E.; Gaál, Emília I.; Lehto, Hanna; Kivisaari, Riku; Laakso, Aki; Niemelä, Mika; Hernesniemi, Juha; Brouwer, Matthijs C.; van de Beek, Diederik; Rinkel, Gabriël J. E.; Ruigrok, Ynte M.

    2014-01-01

    We investigated whether risk alleles of single nucleotide polymorphisms associated with intracranial aneurysm (IA) are enriched in patients with familial IA, IA located at the middle cerebral artery (MCA), or IA rupture at a younger age. In this case-only study, we calculated genetic risk scores

  3. Pitfalls in the use of spiral CT for identification of intracranial aneurysms

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Dorsch, N.W.C.

    1999-01-01

    We describe problems encountered in our first 136 patients, with 95 aneurysms, who underwent spiral CT for investigation of possible aneurysms involving the circle of Willis and adjacent major vessels, and who had surgical and/or angiographic confirmation. There were seven false-positive cases, of which the first three could be explained by operator inexperience. There were four false negatives, all small aneurysms; two were not seen because of operator error and two were hidden by an adjacent larger aneurysm. Clip artefacts prevented diagnostic studies in six of 21 postoperative studies. One aneurysm was outside the CT field of view, being on a pericallosal artery. One basilar artery tip aneurysm was excluded from the field of the CT study because of a planning error. Inspection of the axial source images is critical if the diagnosis of small or thrombosed aneurysms is to be made. Close attention to image acquisition and computer modelling is required to reduce errors in spiral CT angiography of intracranial aneurysms. (orig.)

  4. The Clinical Importance of Perforator Preservation in Intracranial Aneurysm Surgery: An Overview with a Review of the Literature.

    Science.gov (United States)

    Joo, Sung-Pil; Kim, Tae-Sun

    2017-01-01

    Clipping for intracranial aneurysms is done to achieve complete occlusion of the aneurysm without a remnant sac. Despite modern advancements of neurosurgical techniques, morbidity related to the clipping of intracranial aneurysms still exists. Clip occlusion of a parent artery or small hidden perforators commonly leads to permanent neurological deficits, and is a serious and unwanted complication. Thus, preserving blood flow in the branches and perforators of a parent artery is very important for successful surgery without postoperative morbidity and mortality. The aim of this review article is to discuss the consequences of perforator injury and how to avoid this phenomenon in aneurysm surgeries using intraoperative monitoring devices.

  5. The pathogenesis shared between abdominal aortic aneurysms and intracranial aneurysms: a microarray analysis.

    Science.gov (United States)

    Wang, Wen; Li, Hao; Zhao, Zheng; Wang, Haoyuan; Zhang, Dong; Zhang, Yan; Lan, Qing; Wang, Jiangfei; Cao, Yong; Zhao, Jizong

    2018-04-01

    Abdominal aortic aneurysms (AAAs) and intracranial saccular aneurysms (IAs) are the most common types of aneurysms. This study was to investigate the common pathogenesis shared between these two kinds of aneurysms. We collected 12 IAs samples and 12 control arteries from the Beijing Tiantan Hospital and performed microarray analysis. In addition, we utilized the microarray datasets of IAs and AAAs from the Gene Expression Omnibus (GEO), in combination with our microarray results, to generate messenger RNA expression profiles for both AAAs and IAs in our study. Functional exploration and protein-protein interaction (PPI) analysis were performed. A total of 727 common genes were differentially expressed (404 was upregulated; 323 was downregulated) for both AAAs and IAs. The GO and pathway analyses showed that the common dysregulated genes were mainly enriched in vascular smooth muscle contraction, muscle contraction, immune response, defense response, cell activation, IL-6 signaling and chemokine signaling pathways, etc. The further protein-protein analysis identified 35 hub nodes, including TNF, IL6, MAPK13, and CCL5. These hub node genes were enriched in inflammatory response, positive regulation of IL-6 production, chemokine signaling pathway, and T/B cell receptor signaling pathway. Our study will gain new insight into the molecular mechanisms for the pathogenesis of both types of aneurysms and provide new therapeutic targets for the patients harboring AAAs and IAs.

  6. Asymptomatic Delayed Coil Migration from an Intracranial Aneurysm: A Case Report

    Directory of Open Access Journals (Sweden)

    Anirban Deep Banerjee

    2011-01-01

    Full Text Available Objective. To describe asymptomatic delayed migration of a coil loop in a patient following successful coil embolization of an anterior communicating artery saccular aneurysm. Methods. A 24-year-old man with a ruptured anterior communicating artery saccular aneurysm underwent coil embolization with one helical ultrasoft coil. Results. A followup CT scan head and a cerebral angiogram one month following the procedure revealed distal migration of an intra-aneurysmal coil loop into the left pericallosal artery. The patient, however, remained asymptomatic. Conclusion. Delayed migration of coil following embolization of an intracranial aneurysm is an extremely rare occurrence. An asymptomatic presentation, as in our patient, is even more unique. The stent-like configuration of the migrated spiral coil loop probably prevented complete occlusion of the blood vessel.

  7. Intracranial aneurysms in children under 1 year of age: a systematic review of the literature

    NARCIS (Netherlands)

    Buis, D. R.; van Ouwerkerk, W. J. R.; Takahata, H.; Vandertop, W. P.

    2006-01-01

    OBJECTIVE: Intracranial aneurysms are very rare in early childhood. Because the location, morphology as well as the clinical and radiological presentation of these aneurysms seem to be different from those in adults, we performed a systematic review of the literature to discuss the clinical,

  8. 3D printing of an aortic aneurysm to facilitate decision making and device selection for endovascular aneurysm repair in complex neck anatomy.

    Science.gov (United States)

    Tam, Matthew D B S; Laycock, Stephen D; Brown, James R I; Jakeways, Matthew

    2013-12-01

    To describe rapid prototyping or 3-dimensional (3D) printing of aneurysms with complex neck anatomy to facilitate endovascular aneurysm repair (EVAR). A 75-year-old man had a 6.6-cm infrarenal aortic aneurysm that appeared on computed tomographic angiography to have a sharp neck angulation of ~90°. However, although the computed tomography (CT) data were analyzed using centerline of flow, the true neck length and relations of the ostial origins were difficult to determine. No multidisciplinary consensus could be reached as to which stent-graft to use owing to these borderline features of the neck anatomy. Based on past experience with rapid prototyping technology, a decision was taken to print a model of the aneurysm to aid in visualization of the neck anatomy. The CT data were segmented, processed, and converted into a stereolithographic format representing the lumen as a 3D volume, from which a full-sized replica was printed within 24 hours. The model demonstrated that the neck was adequate for stent-graft repair using the Aorfix device. Rapid prototyping of aortic aneurysms is feasible and can aid decision making and device delivery. Further work is required to test the value of 3D replicas in planning procedures and their impact on procedure time, radiation dose, and procedure cost.

  9. Results of the ANSWER Trial Using the PulseRider for the Treatment of Broad-Necked, Bifurcation Aneurysms.

    Science.gov (United States)

    Spiotta, Alejandro M; Derdeyn, Colin P; Tateshima, Satoshi; Mocco, Jay; Crowley, R Webster; Liu, Kenneth C; Jensen, Lee; Ebersole, Koji; Reeves, Alan; Lopes, Demetrius K; Hanel, Ricardo A; Sauvageau, Eric; Duckwiler, Gary; Siddiqui, Adnan; Levy, Elad; Puri, Ajit; Pride, Lee; Novakovic, Roberta; Chaudry, M Imran; Turner, Raymond D; Turk, Aquilla S

    2017-07-01

    The safety and probable benefit of the PulseRider (Pulsar Vascular, Los Gatos, California) for the treatment of broad-necked, bifurcation aneurysms was studied in the context of the prospective, nonrandomized, single arm clinical trial-the Adjunctive Neurovascular Support of Wide-neck aneurysm Embolization and Reconstruction (ANSWER) Trial. To present the results of the United States cases employing the PulseRider device as part of the ANSWER clinical trial. Aneurysms treated with the PulseRider device among sites enrolling in the ANSWER trial were prospectively studied and the results are summarized. Aneurysms arising at either the carotid terminus or basilar apex that were relatively broad necked were considered candidates for inclusion into the ANSWER study. Thirty-four patients were enrolled (29 female and 5 male) with a mean age of 60.9 years (27 basilar apex and 7 carotid terminus). Mean aneurysm height ranged from 2.4 to 15.9 mm with a mean neck size of 5.2 mm (range 2.3-11.6 mm). In all patients, the device was delivered and deployed. Immediate Raymond I or II occlusion was achieved in 82.4% and progressed to 87.9% at 6-month follow-up. A modified Rankin Score of 2 or less was seen in 94% of patients at 6 months. The results from the ANSWER trial demonstrate that the PulseRider device is safe and offers probable benefit as for the treatment of bifurcation aneurysms arising at the basilar apex or carotid terminus. As such, it represents a useful addition to the armamentarium of the neuroendovascular specialist. Copyright © 2017 by the Congress of Neurological Surgeons

  10. Computed tomography in ruptured intracranial aneurysm

    International Nuclear Information System (INIS)

    Suzuki, Michiyasu; Ogawa, Akira; Sakurai, Yoshiharu; Komatsu, Shinro; Suzuki, Jiro.

    1983-01-01

    The differences between initial bleeding and rebleeding due to ruptured intracranial aneurysm was investigated by CT. The study included 120 cases of ruptured cerebral aneurysm; 71 cases had only one bleeding and 49 cases had rebleeding. All the cases underwent CT examinations within 2 weeks following bleeding. Subarachnoid hemorrhages were classified into three groups according to the CT findings: Diffuse high type-high density areas in the entire basal cistern; Localized high type-high density area in a restricted part of the basal cistern; and Iso or Low type-no high density areas in the basal cistern. CT scans done within 24 hours following initial bleeding showed Diffuse high type in 96% of the cases and Localized high type in 4%. On the other hand, in rebleeding cases, Diffuse high type was 50%, Localized high type 25% and Iso or Low type 25%. In rebleeding cases within three days following initial bleeding, Diffuse high type was 90% and Iso or Low type 10%. However, between day 4 and day 14, Diffuse high type was 14%, Localized high type 42% and Iso or Low type 42%. After day 15, Diffuse high type was 36%, Localized type 36% and Iso or Low type 28%. Intracerebral hematoma and/or ventricular hemorrhage secondary to ruptured aneurysms were also investigated. Following initial bleeding, 18% of cases showed intracerebral and/or ventricular hemorrhage, however, the incidence increased up to 59% in rebleeding cases. These observations indicate that the subarachnoid hemorrhage due to re-ruptured aneurysm tends to be more localized than in initial bleeding cases and that intracerebral and/or ventricular hemorrhage seems more frequent in rebleeding cases. (author)

  11. Three-dimensional finite volume modelling of blood flow in simulated angular neck abdominal aortic aneurysm

    Science.gov (United States)

    Algabri, Y. A.; Rookkapan, S.; Chatpun, S.

    2017-09-01

    An abdominal aortic aneurysm (AAA) is considered a deadly cardiovascular disease that defined as a focal dilation of blood artery. The healthy aorta size is between 15 and 24 mm based on gender, bodyweight, and age. When the diameter increased to 30 mm or more, the rupture can occur if it is kept growing or untreated. Moreover, the proximal angular neck of aneurysm is categorized as a significant morphological feature with prime harmful effects on endovascular aneurysm repair (EVAR). Flow pattern in pathological vessel can influence the vascular intervention. The aim of this study is to investigate the blood flow behaviours in angular neck abdominal aortic aneurysm with simulated geometry based on patient’s information using computational fluid dynamics (CFD). The 3D angular neck AAA models have been designed by using SolidWorks Software. Consequently, CFD tools are used for simulating these 3D models of angular neck AAA in ANSYS FLUENT Software. Eventually, based on the results, we summarized that the CFD techniques have shown high performance in explaining and investigating the flow patterns for angular neck abdominal aortic aneurysm.

  12. Intracranial aneurysms: optimized diagnostic tools call for thorough interdisciplinary treatment strategies.

    Science.gov (United States)

    Mueller, Oliver M; Schlamann, Marc; Mueller, Daniela; Sandalcioglu, I Erol; Forsting, Michael; Sure, Ulrich

    2011-09-01

    Intracranial aneurysms (IAs) require deliberately selected treatment strategies as they are incrementally found prior to rupture and deleterious subarachnoid haemorrhage (SAH). Multiple and recurrent aneurysms necessitate both neurointerventionalists and neurosurgeons to optimize aneurysmal occlusion in an interdisciplinary effort. The present study was conducted to condense essential strategies from a single neurovascular centre with regard to the lessons learned. Medical charts of 321 consecutive patients treated for IAs at our centre from September 2008 until December 2010 were retrospectively analysed for clinical presentation of the aneurysms, multiplicity and treatment pathways. In addition, a selective Medline search was performed. A total of 321 patients with 492 aneurysms underwent occlusion of their symptomatic aneurysm: 132 (41.1%) individuals were treated surgically, 189 (58.2%) interventionally; 138 patients presented with a SAH, of these 44.2% were clipped and 55.8% were coiled. Aneurysms of the middle cerebral artery were primarily occluded surgically (88), whereas most of the aneurysms of the internal carotid artery and anterior communicating artery (114) were treated endovascularly. Multiple aneurysms (range 2-5 aneurysms/individual) were diagnosed in 98 patients (30.2%). During the study period 12 patients with recurrent aneurysms were allocated to another treatment modality (previously clip to coil and vice versa). Our data show that successful interdisciplinary occlusion of IAs is based on both neurosurgical and neurointerventional therapy. In particular, multiple and recurrent aneurysms require tailored individual approaches to aneurysmal occlusion. This is achieved by a consequent interdisciplinary pondering of the optimal strategy to occlude IAs in order to prevent SAH.

  13. Combined stent implantation and embolization with liquid 2-polyhydroxyethyl methacrylate for treatment of experimental canine wide-necked aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Klisch, J.; Zitt, J.; Schumacher, M. [Section of Neuroradiology, University of Freiburg (Germany); Schellhammer, F. [Department of Radiology, University of Cologne, Cologne (Germany); Scheufler, K.M. [Department of Neurosurgery, University of Freiburg (Germany); Pagenstecher, A. [Department of Neuropathology, University of Freiburg, Freiburg (Germany); Nagursky, H. [Department of Oral and Maxillofacial Surgery, University of Freiburg, Freiburg (Germany)

    2002-06-01

    The purpose of the study was the evaluation of 2-polyhydroxyethyl methacrylate (2-P-HEMA) for endovascular liquid embolization of experimental side-wall aneurysms following stent protection in a canine model. The swelling behaviour and polymerization characteristics of 2-P-HEMA in different solutions were investigated in vitro. Different methods for applications were tested in a latex aneurysm model under pulsatile flow conditions. Twenty broad-based carotid side-wall aneurysms were microsurgically produced in five dogs. Four weeks after surgery self-expandable nitinol stents were placed, covering the orifice of the aneurysms. 2-P-HEMA was injected via a microcatheter, which was positioned through the meshwork of the stent. Control angiography was performed immediately after treatment and after 1, 6 and 9 months. In-vivo stent placement succeeded in all but one case. Two aneurysms occluded spontaneously after stent placement. Combined embolization of 17 aneurysms using a stent and 2-P-HEMA was performed. Eleven aneurysms could be primarily completely occluded (65%). A small remaining neck was evident in six aneurysms. Efflux of 2-P-HEMA during the process of embolization was observed in seven aneurysms, due to an excess volume of 2-P-HEMA. The excessive 2-P-HEMA led to significant vessel stenosis in two cases. Two carotid arteries (three treated aneurysms) occluded after 1 month, due to insufficient anticoagulation management. Histological examination of embolized aneurysms revealed no foreign-body or inflammatory reaction. A smooth neo-intimal layer covered the stented vessel segment. Liquid embolization of side-wall aneurysms with 2-P-HEMA is technically feasible. Embolotherapy of aneurysms with liquid agents still has the risk that embolic material will exit even when it is stent-protected. To avoid this problem, stents with smaller strut diameter and/or additional balloon-protection are required. The inert 2-P-HEMA seems to be a promising agent for combining

  14. High prevalence of intracranial aneurysms in patients with aortic dissection or aneurysm: feasibility of extended aorta CT angiography with involvement of intracranial arteries.

    Science.gov (United States)

    Lee, Dahye; Ahn, Sung Jun; Cho, Eun-Suk; Kim, Yong Bae; Song, Suk-Won; Jung, Woo Sang; Suh, Sang Hyun

    2017-10-01

    Previous studies have suggested a higher prevalence of intracranial aneurysms (IAs) in patients with aortic aneurysms (AAs). To carry out a preliminary study to evaluate the prevalence of IAs in these patients and the diagnostic feasibility of extended aorta CT angiography (CTA), including intracranial arteries as well as the aorta. We retrospectively reviewed all patients with a clinical diagnosis of AA or aortic dissection (AD) who had undergone aorta CTA as well as MR angiography, CTA, and/or DSA of the brain between 2009 and 2014. Since 2012, the extended aorta CTA protocol has been applied in these patients. Characteristics of IAs were classified with baseline clinical data. For quantitative and qualitative assessment by two independent raters, brain images obtained by extended aorta CTA and brain CTA were compared. The radiation dose of the two aorta protocols was compared. The prevalence of IA was 22.2% (35/158). All IAs were detected by extended aorta CTA, except one small aneurysm (product of the extended aorta CTA increased with increment of the scan range (p=0.048). With a high prevalence of IAs in patients with ADs or AAs, extended aorta CTA could be used to evaluate aorta disease and IA in a single session. However, further prospective studies are needed to prove efficacy and safety of the extended aorta CTA protocol in patients with AAs or ADs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  15. Intrinsic, Transitional, and Extrinsic Morphological Factors Associated With Rupture of Intracranial Aneurysms.

    Science.gov (United States)

    Ho, Allen L; Lin, Ning; Frerichs, Kai U; Du, Rose

    2015-09-01

    As diagnosis and treatment of unruptured intracranial aneurysms continues to increase, management principles remain largely based on size. This is despite mounting evidence that aneurysm location and other morphologic variables could play a role in predicting overall risk of rupture. Morphological parameters can be divided into 3 main groups, those that are intrinsic to the aneurysm, those that are extrinsic to the aneurysm, and those that involve both the aneurysm and surrounding vasculature (transitional). We present an evaluation of intrinsic, transitional, and extrinsic factors and their association with ruptured aneurysms. Using preoperative computed tomographic angiography, we generated 3-dimensional models of aneurysms and their surrounding vasculature with Slicer software. Using univariate and multivariate analyses, we examined the association of intrinsic, transitional, and extrinsic aspects of aneurysm morphology with rupture. Between 2005 and 2013, 227 cerebral aneurysms in 4 locations were evaluated/treated at a single institution, and computed tomographic angiographies of 218 patients (97 unruptured and 130 ruptured) were analyzed. Ruptured aneurysms analyzed were associated with clinical factors of absence of multiple aneurysms and history of no prior rupture, and morphologic factors of greater aspect ratio. On multivariate analysis, aneurysm rupture remained associated with history of no prior rupture, greater flow angle, greater daughter-daughter vessel angle, and smaller parent-daughter vessel angle. By studying the morphology of aneurysms and their surrounding vasculature, we identified several parameters associated with ruptured aneurysms that include intrinsic, transitional, and extrinsic factors of cerebral aneurysms and their surrounding vasculature.

  16. Large Intracranial Aneurysm after Transsphenoidal Surgery for Pituitary Macroadenoma

    OpenAIRE

    Yoon, Kyeong-Wook; Cho, Chun-Sung; Lee, Sang-Koo

    2014-01-01

    Uncontrolled cerebrospinal fluid (CSF) leakage after transsphenoidal surgery (TSS) for pituitary adenoma can lead to meningitis. Intracranial mycotic pseudoaneurysm is a rare complication in central nervous system infection. Large single pseudoaneurysm is more uncommon. Most mycotic aneurysms occur due to endocarditis. The present patient had no heart problem and was infected by CSF leakage after transsphenoidal surgery. We present a case of large ruptured mycotic pseudoaneurysm as a complica...

  17. Multiple intracranial aneurysms in polyarteritis nodosa: MRI and angiography

    International Nuclear Information System (INIS)

    Oran, I.; Memis, A.; Parildar, M.; Yunten, N.

    1999-01-01

    In polyarteritis nodosa involvement of the central nervous system is infrequent; small cerebral infarcts are the most common neuroradiological finding. We report a 10-year-old boy with polyarteritis nodosa and intracranial haemorrhage. MRI showed an intracerebral haemorrhage. Angiography revealed two peripheral aneurysms in the posterior cerebral circulation, previously reported on only two occasions, and multiple microaneurysms in the hepatic, renal, mesenteric and even the lumbar arteries. (orig.)

  18. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    International Nuclear Information System (INIS)

    Mühlenbruch, Georg; Nikoubashman, Omid; Steffen, Björn; Dadak, Mete; Palmowski, Moritz; Wiesmann, Martin

    2013-01-01

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  19. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenbruch, Georg, E-mail: gmuehlenbruch@ukaachen.de; Nikoubashman, Omid; Steffen, Bjoern; Dadak, Mete [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany); Palmowski, Moritz [RWTH Aachen University, Department of Nuclear Medicine, University Hospital (Germany); Wiesmann, Martin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany)

    2013-02-15

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  20. Morphological and clinical risk factors for posterior communicating artery aneurysm rupture.

    Science.gov (United States)

    Matsukawa, Hidetoshi; Fujii, Motoharu; Akaike, Gensuke; Uemura, Akihiro; Takahashi, Osamu; Niimi, Yasunari; Shinoda, Masaki

    2014-01-01

    Recent studies have shown that posterior circulation aneurysms, specifically posterior communicating artery (PCoA) aneurysms, are more likely to rupture than other aneurysms. To date, few studies have investigated the factors contributing to PCoA aneurysm rupture. The authors aimed to identify morphological and clinical characteristics predisposing to PCoA aneurysm rupture. The authors retrospectively reviewed 134 consecutive patients with PCoA aneurysms managed at their facility between July 2003 and December 2012. The authors divided patients into groups of those with aneurysmal rupture (n = 39) and without aneurysmal rupture (n = 95) and compared morphological and clinical characteristics. Morphological characteristics were mainly evaluated by 3D CT angiography and included diameter of arteries (anterior cerebral artery, middle cerebral artery, and internal carotid artery), size of the aneurysm, dome-to-neck ratio, neck direction of the aneurysmal dome around the PCoA (medial, lateral, superior, inferior, and posterior), aneurysm bleb formation, whether the PCoA was fetal type, and the existence of other intracranial unruptured aneurysm(s). Patients with ruptured PCoA aneurysms were significantly younger (a higher proportion were PCoA aneurysms showed a lateral direction of the aneurysmal dome around the PCoA, had bleb formation, and the aneurysm was > 7 mm in diameter and/or the dome-to-neck ratio was > 2.0. Multivariate logistic regression analysis showed age PCoA (OR 6.7, p = 0.0001), and bleb formation (OR 11, p PCoA aneurysm rupture. The present results demonstrated that lateral projection of a PCoA aneurysm may be related to rupture.

  1. Endovascular Embolization of Intracranial Infectious Aneurysms in Patients Undergoing Open Heart Surgery Using n-Butyl Cyanoacrylate.

    Science.gov (United States)

    Cheng-Ching, Esteban; John, Seby; Bain, Mark; Toth, Gabor; Masaryk, Thomas; Hui, Ferdinand; Hussain, Muhammad Shazam

    2017-03-01

    Mycotic aneurysms are a serious complication of infective endocarditis with increased risk of intracranial hemorrhage. Patients undergoing open heart surgery for valve repair or replacement are exposed to anticoagulants, increasing the risk of aneurysm bleeding. These patients may require endovascular or surgical aneurysm treatment prior to heart surgery, but data on this approach are scarce. Retrospective review of consecutive patients with infectious endocarditis and mycotic aneurysms treated endovascularly with Trufill n-butyl cyanoacrylate (n-BCA) at the Cleveland Clinic between January 2013 and December 2015. Nine patients underwent endovascular treatment of mycotic aneurysms with n-BCA (mean age of 39 years). On imaging, 4 patients had intracerebral hemorrhage, 2 had multiple embolic infarcts, and the rest had no imaging findings. Twelve mycotic aneurysms were detected (3 patients with 2 aneurysms). Seven aneurysms were in the M4 middle cerebral artery segment, 4 in the posterior cerebral artery distribution, and 1 in the callosomarginal branch. n-BCA was diluted in ethiodized oil (1:1 to 1:2). Embolization was achieved in a single rapid injection with immediate microcatheter removal. Complete aneurysm exclusion was achieved in all cases without complications. All patients underwent open heart surgery and endovascular embolization within a short interval, 2 with both procedures on the same day. There were no new hemorrhages after aneurysm embolization. Endovascular embolization of infectious intracranial aneurysms with liquid embolics can be performed successfully in critically ill patients requiring immediate open heart surgery and anticoagulation. Early embolization prior to and within a short interval from open heart surgery is feasible.

  2. Morphological and Hemodynamic Discriminators for Rupture Status in Posterior Communicating Artery Aneurysms.

    Directory of Open Access Journals (Sweden)

    Nan Lv

    Full Text Available The conflicting findings of previous morphological and hemodynamic studies on intracranial aneurysm rupture may be caused by the relatively small sample sizes and the variation in location of the patient-specific aneurysm models. We aimed to determine the discriminators for aneurysm rupture status by focusing on only posterior communicating artery (PCoA aneurysms.In 129 PCoA aneurysms (85 ruptured, 44 unruptured, clinical, morphological and hemodynamic characteristics were compared between the ruptured and unruptured cases. Multivariate logistic regression analysis was performed to determine the discriminators for rupture status of PCoA aneurysms.While univariate analyses showed that the size of aneurysm dome, aspect ratio (AR, size ratio (SR, dome-to-neck ratio (DN, inflow angle (IA, normalized wall shear stress (NWSS and percentage of low wall shear stress area (LSA were significantly associated with PCoA aneurysm rupture status. With multivariate analyses, significance was only retained for higher IA (OR = 1.539, p < 0.001 and LSA (OR = 1.393, p = 0.041.Hemodynamics and morphology were related to rupture status of intracranial aneurysms. Higher IA and LSA were identified as discriminators for rupture status of PCoA aneurysms.

  3. The risk of headache attributed to surgical treatment of intracranial aneurysms: a cohort study.

    Science.gov (United States)

    Magalhães, João E; Azevedo-Filho, Hildo R C; Rocha-Filho, Pedro A S

    2013-01-01

    The aim of this study was to assess the risk of headache in patients undergoing surgical treatment of intracranial aneurysms. The risk of the post-craniotomy headache has never been studied. Patients with intracranial aneurysm, who were consecutively admitted to the Hospital da Restauração, Brazil, from May 2009 to October 2010, were interviewed before they underwent surgical or non-surgical treatment of the aneurysms. The patients were followed for 4 months after intervention. The International Headache Society criteria for post-craniotomy headache were used after surgery and adapted for headache after embolization (maximum intensity of pain on the same side of the aneurysm). We also used the Headache Impact Test, the Hospital Anxiety and Depression Scale, and the Epworth Sleepiness Scale. Of 101 patients enrolled, 53 patients underwent craniotomy and 48 patients embolization. The surgery group was younger and had fewer women. The incidence of headache was 28/51 cases (54.9%) after surgery and 12/47 cases (25.5%) after embolization (relative risk = 2.15; 95% confidence interval [CI] 1.24-3.72). The incidence of persistent headache was not different between the 2 groups. The only risk factor for headache after the intervention was craniotomy (odds ratio = 2.6; 95% CI 1.1-6.7) and for persistent headache was anxiety prior to treatment (odds ratio = 8.5; 95% CI 1.7-42.3). The headache after treatment was not associated with the risk of anxiety or depression after the intervention. Patients who underwent craniotomy had an increased risk of headache after treatment of intracranial aneurysms. The incidence of persistent headache after 3 months was higher among patients who had anxiety before the intervention. © 2013 American Headache Society.

  4. Expression of miR-146a-5p in patients with intracranial aneurysms and its association with prognosis.

    Science.gov (United States)

    Zhang, H-L; Li, L; Cheng, C-J; Sun, X-C

    2018-02-01

    The study aims to detect the association of miR-146a-5p with intracranial aneurysms (IAs). The expression of miR-146a-5p was compared from plasma samples between 72 patients with intracranial aneurysms (IAs) and 40 healthy volunteers by quantitative Real-time polymerase chain reaction (qRT-PCR). Statistical analysis was performed to analyze the relationship between miR-146a-5p expression and clinical data and overall survival (OS) time of IAs patients. Univariate and multivariate Cox proportional hazards have also been performed. Notably, higher miR-146a-5p expression was found in plasma samples from 72 patients with intracranial aneurysms (IAs) compared with 40 healthy controls. Higher miR-146a-5p expression was significantly associated with rupture and Hunt-Hess level in IAs patients. Kaplan-Meier survival analysis verified that higher miR-146a-5p expression predicted a shorter overall survival (OS) compared with lower miR-146a-5p expression in IAs patients. Univariate and multivariate Cox proportional hazards demonstrated that higher miR-146a-5p expression, rupture, and Hunt-Hess were independent risk factors of OS in patients with intracranial aneurysms (IAs). MiR-146a-5p expression may serve as a biomarker for predicting prognosis in patients with IAs.

  5. Relationship between endothelial nitric oxide synthase (eNOS) and natural history of intracranial aneurysms: meta-analysis.

    Science.gov (United States)

    Paschoal, Eric Homero Albuquerque; Yamaki, Vitor Nagai; Teixeira, Renan Kleber Costa; Paschoal Junior, Fernando Mendes; Jong-A-Liem, Glaucia Suzanna; Teixeira, Manoel Jacobsen; Yamada, Elizabeth Sumi; Ribeiro-Dos-Santos, Ândrea; Bor-Seng-Shu, Edson

    2018-01-01

    The aneurysmal subarachnoid hemorrhage is a major public health problem described as a sudden drastic event with no warning symptoms and high morbidity and mortality rates. The role of the endothelial isoform of nitric oxide synthase gene polymorphism in intracranial aneurysms (IAs) is still a matter of controversy with divergent findings among European, American, and Asian populations. Our study purposed to test the association between intracranial aneurysms formation and nitric oxide gene polymorphisms through a systematic review and meta-analysis. Systematic search on Medline, Lilacs, and EMBASE was performed. The primary search resulted in 139 papers, out of which 9 met our inclusion criteria after a full text analysis. The dominant T786C model found a significant association with IA (OR 1.22, 95 % CI 1.04-1.44, p = 0.01), so did studies of the recessive T786C model (OR 0.37, 95 % CI 0.30-0.45, p < 0.0001) but with opposite effect. Our findings support the presence of the T786C polymorphism as a predictor for the development of intracranial aneurysm in the cerebral vascular system. More studies are necessary in order to elucidate the pathways of the endothelial nitric oxide synthase (eNOS) in cerebrovascular diseases and in defining how different allelic combinations of the eNOS gene single-nucleotide polymorphism (SNP) could favor this pathological process.

  6. Size ratio correlates with intracranial aneurysm rupture status: a prospective study.

    Science.gov (United States)

    Rahman, Maryam; Smietana, Janel; Hauck, Erik; Hoh, Brian; Hopkins, Nick; Siddiqui, Adnan; Levy, Elad I; Meng, Hui; Mocco, J

    2010-05-01

    The prediction of intracranial aneurysm (IA) rupture risk has generated significant controversy. The findings of the International Study of Unruptured Intracranial Aneurysms (ISUIA) that small anterior circulation aneurysms (IAs are small. These discrepancies have led to the search for better aneurysm parameters to predict rupture. We previously reported that size ratio (SR), IA size divided by parent vessel diameter, correlated strongly with IA rupture status (ruptured versus unruptured). These data were all collected retrospectively off 3-dimensional angiographic images. Therefore, we performed a blinded prospective collection and evaluation of SR data from 2-dimensional angiographic images for a consecutive series of patients with ruptured and unruptured IAs. We prospectively enrolled 40 consecutive patients presenting to a single institution with either ruptured IA or for first-time evaluation of an incidental IA. Blinded technologists acquired all measurements from 2-dimensional angiographic images. Aneurysm rupture status, location, IA maximum size, and parent vessel diameter were documented. The SR was calculated by dividing the aneurysm size (mm) by the average parent vessel size (mm). A 2-tailed Mann-Whitney test was performed to assess statistical significance between ruptured and unruptured groups. Fisher exact test was used to compare medical comorbidities between the ruptured and unruptured groups. Significant differences between the 2 groups were subsequently tested with logistic regression. SE and probability values are reported. Forty consecutive patients with 24 unruptured and 16 ruptured aneurysms met the inclusion criteria. No significant differences were found in age, gender, smoking status, or medical comorbidities between ruptured and unruptured groups. The average maximum size of the unruptured IAs (6.18 + or - 0.60 mm) was significantly smaller compared with the ruptured IAs (7.91 + or - 0.47 mm; P=0.03), and the unruptured group had

  7. Familial aggregation of intracranial aneurysms in an Inuit patient population in Kalaallit Nunaat (Greenland)

    DEFF Research Database (Denmark)

    Lindgaard, Lars; Eskesen, Vagn; Gjerris, Flemming

    2003-01-01

    The incidence of subarachnoid hemorrhage (SAH) and intracranial aneurysm (IA) has been reported to be higher in Greenlandic Inuits than in Caucasian Danes, but the rate of familial aggregation in Inuits is unknown....

  8. Identification of vortex structures in a cohort of 204 intracranial aneurysms.

    Science.gov (United States)

    Varble, Nicole; Trylesinski, Gabriel; Xiang, Jianping; Snyder, Kenneth; Meng, Hui

    2017-05-01

    An intracranial aneurysm (IA) is a cerebrovascular pathology that can lead to death or disability if ruptured. Abnormal wall shear stress (WSS) has been associated with IA growth and rupture, but little is known about the underlying flow physics related to rupture-prone IAs. Previous studies, based on analysis of a few aneurysms or partial views of three-dimensional vortex structures, suggest that rupture is associated with complex vortical flow inside IAs. To further elucidate the relevance of vortical flow in aneurysm pathophysiology, we studied 204 patient IAs (56 ruptured and 148 unruptured). Using objective quantities to identify three-dimensional vortex structures, we investigated the characteristics associated with aneurysm rupture and if these features correlate with previously proposed WSS and morphological characteristics indicative of IA rupture. Based on the Q -criterion definition of a vortex, we quantified the degree of the aneurysmal region occupied by vortex structures using the volume vortex fraction ( vVF ) and the surface vortex fraction ( sVF ). Computational fluid dynamics simulations showed that the sVF , but not the vVF , discriminated ruptured from unruptured aneurysms. Furthermore, we found that the near-wall vortex structures co-localized with regions of inflow jet breakdown, and significantly correlated to previously proposed haemodynamic and morphologic characteristics of ruptured IAs. © 2017 The Author(s).

  9. MRI-validation of SEP monitoring for ischemic events during microsurgical clipping of intracranial aneurysms.

    Science.gov (United States)

    Krayenbühl, Niklaus; Sarnthein, Johannes; Oinas, Minna; Erdem, Eren; Krisht, Ali F

    2011-09-01

    During surgical clipping of intracranial aneurysms, reduction in SEP amplitude is thought to indicate cortical ischemia and subsequent neurological deficits. Since the sensitivity of SEP is questioned, we investigated SEP with respect to post-operative ischemia. In 36 patients with 51 intracranial aneurysms, clinical evaluation and diffusion-weighted MRI (DWI) was performed before and within 24h after surgery. During surgery, time of temporary occlusion was recorded. MRI images were reviewed for signs of ischemia. For 43 clip applications (84%), we observed neither pathologic SEP events nor ischemia in MRI. In two cases where reduction lasted >10 min after clip release, SEP events correlated with ischemia in the MRI. Only one of the ischemic patients was symptomatic and developed a transient hemiparesis. While pathologic SEP events correlated with visible ischemia in MRI only in two cases with late SEP recovery, ischemia in MRI may have been transient or may not have reached detection threshold in the other cases, in agreement with the absence of permanent neurological deficits. In complex aneurysm cases, where prolonged temporary occlusion is expected, SEP should be used to detect ischemia at a reversible stage to improve the safety of aneurysm clipping. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  10. Pipeline embolization device for intracranial aneurysm: a systematic review.

    Science.gov (United States)

    Leung, G K K; Tsang, A C O; Lui, W M

    2012-12-01

    The pipeline embolization device (PED) is a new endovascular stent designed for the treatment of challenging intracranial aneurysms (IAs). Its use has been extended to nonruptured and ruptured IAs of a variety of configurations and etiologies in both the anterior and posterior circulations. We conducted a systematic review of ten eligible reports on its clinical efficacy and safety. There were 414 patients with 448 IAs. The majority of the IAs were large (40.2 %), saccular or blister-like (78.3 %), and were located mostly in the anterior circulation (83.5 %). The regimens of antiplatelet therapy varied greatly between and within studies. The mean number of the PED used was 2.0 per IA. Deployment was successful in around 95 % of procedures. Aneurysm obliteration was achieved in 82.9 % of IAs at 6-month. The overall incidences of periprocedural intracranial vascular complication rate and mortality rate were 6.3 and 1.5 %, respectively. The PED is a safe and effective treatment for nonruptured IAs. Its use in the context of acute subarachnoid hemorrhage (SAH) should be cautioned. Its main limitations include the need for prolonged antiplatelet therapy, as well as the potential risks of IA rupture and non-IA-related intracerebral hemorrhages (ICH). Future studies should aim at identifying factors that predispose to incomplete obliteration, delayed rupture, and thromboembolic complications.

  11. Psychosocial impact of screening for intracranial aneurysms in relatives with familial subarachnoid hemorrhage

    NARCIS (Netherlands)

    Wermer, M. J. H.; van der Schaaf, I. C.; van Nunen, P.; Bossuyt, P. M. M.; Anderson, C. S.; Rinkel, G. J. E.

    2005-01-01

    Background and Purpose - In families with >= 2 relatives with intracranial aneurysms (IAs), screening for IAs in asymptomatic first-degree relatives is often recommended. We assessed the long-term psychosocial impact of such screening. Methods - We identified all persons with IA (screen-positives)

  12. Remission of migraine after clipping of saccular intracranial aneurysms

    DEFF Research Database (Denmark)

    Lebedeva, E R; Busygina, A V; Kolotvinov, V S

    2015-01-01

    interview. The remission rates of migraine and tension-type headache (TTH) in these patients were compared to 92 patients from a headache center. Diagnoses were made according to the ICHD-2. RESULTS: During 1 year preceding rupture 51 patients with SIA had migraine. During the year after clipping......BACKGROUND: Unruptured saccular intracranial aneurysm (SIA) is associated with an increased prevalence of migraine, but it is unclear whether this is altered by clipping of the aneurysm. The aim of our study was to determine whether remission rate of migraine and other recurrent headaches...... was greater in patients with SIA after clipping than in controls. METHODS: We prospectively studied 87 SIA patients with migraine or other recurrent headaches. They were interviewed about headaches in the preceding year before and 1 year after clipping using a validated semi-structured neurologist conducted...

  13. China's growing contribution to global intracranial aneurysm research (1991-2012: a bibliometric study.

    Directory of Open Access Journals (Sweden)

    Ze-jun Jia

    Full Text Available BACKGROUND: We sought to analyze the growing worldwide trends of intracranial aneurysm research, investigate China's recent contribution, and compare the contributions of mainland China, Taiwan, and Hong Kong. METHODS: Global and China intracranial aneurysm-related publications were retrieved from the Web of Science database from 1991 to 2012. Excel 2007, Matlab, and Thomson Data Analyzer (TDA software were used to analyze the search results for number of publications, cited frequency, h-index, and organization contributions. RESULTS: 16468 global papers were identified that were cited 273500 times until 2013-08-15. The United States accounted for 31.497% of the articles, 58.64% of the citations, and the highest h-index (127. Japan and Germany followed in frequency. China's articles ranked eighth (third in 2012 in total number, with most of the contributions occurring since 2002 (91.33%. China was at the early stage of the logic growth curve (exponential growth, with the citation frequency and h-index per year increasing. The quality of the publications was low. The main research centers were located in Beijing, Shanghai, Taiwan, and Hong Kong. The main Asian funding body was the National Natural Science Foundation of China. The number of publications and frequency of citations of papers from mainland China was greater than that of Taiwan or Hong Kong. CONCLUSION: Global intracranial aneurysm research has been developing swiftly since 1991, with the United States making the largest contribution. Research in China started later, in 2002. Since then, China has increased its rate of publication, and became the third largest contributor by 2012.

  14. Magnetic resonance angiography with ultrashort echo times reduces the artefact of aneurysm clips

    International Nuclear Information System (INIS)

    Goenner, F.; Heid, O.; Remonda, L.; Schroth, G.; Loevblad, K.O.; Guzman, R.; Barth, A.

    2002-01-01

    We evaluated the ability of an ultrashort echo time (TE) three-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) sequence to reduce the metal artefact of intracranial aneurysm clips and to display adjacent cerebral arteries. In five patients (aged 8-72 years) treated with Elgiloy or Phynox aneurysm clips we prospectively performed a conventional (TE 6.0 ms) and a new ultrashort TE (TE 2.4 ms) 3D TOF MRA. We compared the diameter of the clip-induced susceptibility artefact and the detectability of flow in adjacent vessels. The mean artefact diameter was 22.3±6.4 mm (range 14-38 mm) with the ultrashort TE and 27.7±6.4 mm (range 19-45 mm) with the conventional MRA (P<0.0001). This corresponded to a diameter reduction of 19.5±9.2%. More parts of adjacent vessels were detected, but with less intense flow signal. The aneurysm dome and neck remained within the area of signal loss and were therefore not displayed. Ultrashort TE MRA is a noninvasive and fast method for improving detection of vessels adjacent to clipped intracranial aneurysms, by reducing clip-induced susceptibility artefact. The method cannot, however, be used to show remnants of the aneurysm neck or sac as a result of imperfect clipping. (orig.)

  15. Interest of Flow Diversion Prostheses in the Management of Unruptured Intracranial Aneurysms

    Directory of Open Access Journals (Sweden)

    Xavier Armoiry

    2012-01-01

    Full Text Available Flow diversion prostheses represent a new endovascular approach aimed at treating patients with large wide-neck aneurysms. Our objective is to present this new technology, to review the clinical studies on efficacy, and to emphasize its current limits. Flow diversion prostheses consist of a cylinder made of a large number of braided microfilaments providing a large metallic surface when deployed and inducing a blood flow diversion outside the aneurysm. Two different brands are currently available. Clinical data supporting their efficacy are currently limited to six non comparative cohort studies that included between 18 and 107 patients. Procedural implantation was shown to be feasible in more than 90% and safe with a thirty-day mortality between 2.8 and 5.5%. Complete occlusion rates at twelve months varied between 85.7 and 100%. Even though promising, the current status of flow diversion prostheses needs further evaluation with randomized, prospective, clinical trials with comparison to conventional strategies including endovascular coiling or surgical clipping.

  16. The comparison of aneurysmal necks measured on three dimensional reconstruction images of rotational DSA and those of traditional DSA

    International Nuclear Information System (INIS)

    Wu Chunhong; Chen Zuoquan; Gu Binxian; Zhang Guiyun

    2006-01-01

    Objective: To evaluate the value of three dimensional reconstruction images of rotational DSA on measuring aneurysmal necks and make a comparison with traditional DSA so as to provide more abundant and accurate information for the embolization of aneurysm. Methods: A comparison was made between the measurement of aneurismal necks from 14 cases with traditional DSA examination and a measurement made on three dimensional reconstruction images of the same patients. Results: There was a difference shown in the measurement of the aneurysmal necks between three dimensional reconstruction images of rotational DSA and those of traditional DSA, outcoming with more angles and data on three dimensional reconstruction images. Conclusions: There are more angles of aneurysmal neck can be shown on rotational 3D DSA especially for the demonstration of the largest aneurysmal neck with a directional value for the intervention. (authors)

  17. Treatment of ruptured intracranial aneurysms: implications of the ISAT on clipping versus coiling

    NARCIS (Netherlands)

    van den Berg, R.; Rinkel, G. J. E.; Vandertop, W. P.

    2003-01-01

    Patients with a ruptured intracranial aneurysm should be treated as soon as possible after the haemorrhage to prevent rebleeding and to allow vigorous treatment of ischemic events in case of vasospasm. The choice of treatment, endovascular or surgical, should be based on the angio-architectural

  18. Polycystic kidney disease among 4,436 intracranial aneurysm patients from a defined population.

    Science.gov (United States)

    Nurmonen, Heidi J; Huttunen, Terhi; Huttunen, Jukka; Kurki, Mitja I; Helin, Katariina; Koivisto, Timo; von Und Zu Fraunberg, Mikael; Jääskeläinen, Juha E; Lindgren, Antti E

    2017-10-31

    To define the association of autosomal dominant polycystic kidney disease (ADPKD) with the characteristics of aneurysmal subarachnoid hemorrhage (aSAH) and unruptured intracranial aneurysm (IA) disease. We fused data from the Kuopio Intracranial Aneurysm database (n = 4,436 IA patients) and Finnish nationwide registries into a population-based series of 53 IA patients with ADPKD to compare the aneurysm- and patient-specific characteristics of IA disease in ADPKD and in the general IA population, and to identify risks for de novo IA formation. In total, there were 33 patients with ADPKD with aSAH and 20 patients with ADPKD with unruptured IAs. The median size of ruptured IAs in ADPKD was significantly smaller than in the general population (6.00 vs 8.00 mm) and the proportion of small ruptured IAs was significantly higher (31% vs 18%). Median age at aSAH was 42.8 years, 10 years younger than in the general IA population. Multiple IAs were present in 45% of patients with ADPKD compared to 28% in the general IA population. Cumulative risk of de novo IA formation was 1.3% per patient-year (vs 0.2% in the general IA population). Hazard for de novo aneurysm formation was significantly elevated in patients with ADPKD (Cox regression hazard ratio 7.7, 95% confidence interval 2.8-20; p IAs in patients with ADPKD and risk for de novo IAs is higher than in the general Eastern Finnish population. ADPKD should be considered as an indicator for long-term angiographic follow-up in patients with diagnosed IAs. © 2017 American Academy of Neurology.

  19. Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models

    Directory of Open Access Journals (Sweden)

    Anderson Chun On Tsang

    2015-04-01

    Full Text Available Purpose: The aim of this study was to validate a computational fluid dynamics (CFD simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. Results: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. Conclusion: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents.

  20. CFD and PIV analysis of hemodynamics in a growing intracranial aneurysm.

    Science.gov (United States)

    Raschi, Marcelo; Mut, Fernando; Byrne, Greg; Putman, Christopher M; Tateshima, Satoshi; Viñuela, Fernando; Tanoue, Tetsuya; Tanishita, Kazuo; Cebral, Juan R

    2012-02-01

    Hemodynamics is thought to be a fundamental factor in the formation, progression, and rupture of cerebral aneurysms. Understanding these mechanisms is important to improve their rupture risk assessment and treatment. In this study, we analyze the blood flow field in a growing cerebral aneurysm using experimental particle image velocimetry (PIV) and computational fluid dynamics (CFD) techniques. Patient-specific models were constructed from longitudinal 3D computed tomography angiography images acquired at 1-y intervals. Physical silicone models were constructed from the computed tomography angiography images using rapid prototyping techniques, and pulsatile flow fields were measured with PIV. Corresponding CFD models were created and run under matching flow conditions. Both flow fields were aligned, interpolated, and compared qualitatively by inspection and quantitatively by defining similarity measures between the PIV and CFD vector fields. Results showed that both flow fields were in good agreement. Specifically, both techniques provided consistent representations of the main intra-aneurysmal flow structures and their change during the geometric evolution of the aneurysm. Despite differences observed mainly in the near wall region, and the inherent limitations of each technique, the information derived is consistent and can be used to study the role of hemodynamics in the natural history of intracranial aneurysms.

  1. Microcatheter Shaping for Intracranial Aneurysm Coiling Using the 3-Dimensional Printing Rapid Prototyping Technology: Preliminary Result in the First 10 Consecutive Cases.

    Science.gov (United States)

    Namba, Katsunari; Higaki, Ayuho; Kaneko, Naoki; Mashiko, Toshihiro; Nemoto, Shigeru; Watanabe, Eiju

    2015-07-01

    An optimal microcatheter is necessary for successful coiling of an intracranial aneurysm. The optimal shape may be predetermined before the endovascular surgery via the use of a 3-dimensional (3D) printing rapid prototyping technology. We report a preliminary series of intracranial aneurysms treated with a microcatheter shape determined by the patient's anatomy and configuration of the aneurysm, which was fabricated with a 3D printer aneurysm model. A solid aneurysm model was fabricated with a 3D printer based on the data acquired from the 3D rotational angiogram. A hollow aneurysm model with an identical vessel and aneurysm lumen to the actual anatomy was constructed with use of the solid model as a mold. With use of the solid model, a microcatheter shaping mandrel was formed to identically line the 3D curvature of the parent vessel and the long axis of the aneurysm. With use of the mandrel, a test microcatheter was shaped and validated for the accuracy with the hollow model. All the planning processes were undertaken at least 1 day before treatment. The preshaped mandrel was then applied in the endovascular procedure. Ten consecutive intracranial aneurysms were coiled with the pre-planned shape of the microcatheter and evaluated for the clinical and anatomical outcomes and microcatheter accuracy and stability. All of pre-planned microcatheters matched the vessel and aneurysm anatomy. Seven required no microguidewire assistance in catheterizing the aneurysm whereas 3 required guiding of a microguidewire. All of the microcatheters accurately aligned the long axis of the aneurysm. The pre-planned microcatheter shapes demonstrated stability in all except in 1 large aneurysm case. When a 3D printing rapid type prototyping technology is used, a patient-specific and optimal microcatheter shape may be determined preoperatively. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Long-term recurrent subarachnoid hemorrhage after adequate coiling versus clipping of ruptured intracranial aneurysms

    NARCIS (Netherlands)

    Schaafsma, Joanna D.; Sprengers, Marieke E.; van Rooij, Willem Jan; Sluzewski, Menno; Majoie, Charles B. L. M.; Wermer, Marieke J. H.; Rinkel, Gabriel J. E.

    2009-01-01

    BACKGROUND AND PURPOSE: Coiling is increasingly used as treatment for intracranial aneurysms. Despite its favorable short-term outcome, concerns exist about long-term reopening and inherent risk of recurrent subarachnoid hemorrhage (SAH). We hypothesized a higher risk for recurrent SAH after

  3. Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: Comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Pozzi-Mucelli, Fabio; Bruni, Stefano; Doddi, Marco; Calgaro, Antonio; Braini, Massimiliano; Cova, Maria

    2007-01-01

    Purpose: To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. Methods and materials: Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. Results: In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. Conclusions: 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect

  4. Detection of intracranial aneurysms using three-dimensional multidetector-row CT angiography: Is bone subtraction necessary?

    International Nuclear Information System (INIS)

    Hwang, Seung Bae; Kwak, Hyo Sung; Han, Young Min; Chung, Gyung Ho

    2011-01-01

    Purpose: The aim of this study was to evaluate the usefulness of three-dimensional CT angiography (3D CTA) with bone subtraction in a comparison with 3D CTA without bone subtraction for the detection of intracranial aneurysms. Materials and methods: Among 337 consecutive patients who had intracranial aneurysms detected on 3D CTA, 170 patients who underwent digital subtraction angiography (DSA) were included in the study. CTA was performed with a 16-slice multidetector-row CT (MDCT) scanner. We created the 3D reconstruction images with and without bone subtraction by using the volume rendering technique. Three neuroradiologists in a blinded fashion interpreted both 3D CTA images with and without bone subtraction. The diagnostic accuracy of both techniques was evaluated using the alternative free-response receiver operating characteristic (ROC) analysis. The sensitivity and positive predictive value were also evaluated. Results: A total of 200 aneurysms (size: 2-23 mm) were detected in 170 patients. The area under the receiver operating characteristic curve (Az) for 3D CTA with bone subtraction (mean, Az = 0.933) was significantly higher than that for 3D CTA without bone subtraction (mean, Az = 0.879) for all observers (P < 0.05). The sensitivity of 3D CTA with bone subtraction for three observers was 90.0, 92.0 and 92.5%, respectively, while the sensitivity of 3D CTA without bone subtraction was 83.5, 83.5 and 87.5%, respectively. No significant difference in positive predictive value was observed between the two modalities. Conclusions: 3D CTA with bone subtraction showed significantly higher diagnostic accuracy for the detection of intracranial aneurysms as compared to 3D CTA without bone subtraction.

  5. Comparison of hemodynamics of intracranial aneurysms between MR fluid dynamics using 3D cine phase-contrast MRI and MR-based computational fluid dynamics

    International Nuclear Information System (INIS)

    Isoda, Haruo; Sakahara, Harumi; Ohkura, Yasuhide; Kosugi, Takashi; Hirano, Masaya; Alley, Marcus T.; Bammer, Roland; Pelc, Norbert J.; Namba, Hiroki

    2010-01-01

    Hemodynamics is thought to play a very important role in the initiation, growth, and rupture of intracranial aneurysms. The purpose of our study was to compare hemodynamics of intracranial aneurysms of MR fluid dynamics (MRFD) using 3D cine PC MR imaging (4D-Flow) at 1.5 T and MR-based computational fluid dynamics (CFD). 4D-Flow was performed for five intracranial aneurysms by a 1.5 T MR scanner. 3D TOF MR angiography was performed for geometric information. The blood flow in the aneurysms was modeled using CFD simulation based on the finite element method. We used MR angiographic data as the vascular models and MR flow information as boundary conditions in CFD. 3D velocity vector fields, 3D streamlines, shearing velocity maps, wall shear stress (WSS) distribution maps and oscillatory shear index (OSI) distribution maps were obtained by MRFD and CFD and were compared. There was a moderate to high degree of correlation in 3D velocity vector fields and a low to moderate degree of correlation in WSS of aneurysms between MRFD and CFD using regression analysis. The patterns of 3D streamlines were similar between MRFD and CFD. The small and rotating shearing velocities and higher OSI were observed at the top of the spiral flow in the aneurysms. The pattern and location of shearing velocity in MRFD and CFD were similar. The location of high oscillatory shear index obtained by MRFD was near to that obtained by CFD. MRFD and CFD of intracranial aneurysms correlated fairly well. (orig.)

  6. Long-Term Recurrent Subarachnoid Hemorrhage After Adequate Coiling Versus Clipping of Ruptured Intracranial Aneurysms

    NARCIS (Netherlands)

    Schaafsma, Joanna D.; Sprengers, Marieke E.; van Rooij, Willem Jan; Sluzewski, Menno; Majoie, Charles B. L. M.; Wermer, Marieke J. H.; Rinkel, Gabriel J. E.

    Background and Purpose-Coiling is increasingly used as treatment for intracranial aneurysms. Despite its favorable short-term outcome, concerns exist about long-term reopening and inherent risk of recurrent subarachnoid hemorrhage (SAH). We hypothesized a higher risk for recurrent SAH after adequate

  7. Effects of indocyanine green videoangiography and electrophysiological monitoring on surgery for intracranial aneurysms

    International Nuclear Information System (INIS)

    Arai, Yoshikazu; Kitai, Ryuhei; Awara, Kosuke

    2011-01-01

    We analyzed the outcome of 62 consecutive patients with unruptured intracranial aneurysm treated by surgical clipping. Thirty-one cases were operated without intraoperative monitoring, 17 cases with indocyanine green videoangiography (ICGA), and 14 cases with electrophysiological monitoring (EPM) in addition to ICGA. Complete obliteration of the aneurysm was confirmed in all 62 cases. Diffusion-weighted imaging of MRI disclosed no ischemic lesions after surgery in any of the cases. Asymptomatic venous infarction was detected by CT study in 2 cases. Cranial nerve palsy occurred in 4 cases but EPM could not detect it. There was no difference among the group without monitoring, the group with ICGA and the group with ICGA and EPM. The mortality and morbidity of all cases was calculated as 0% and 6.5%, respectively. ICGA appeared to be useful in surgery for aneurysms encasing perforators or for repair of problems such as premature rupture. eicosapentaenoic acid (EPA) seemed effective in surgery for anterior choroidal artery aneurysms or aneurysms requiring trapping before clipping. However, monitoring would not have been effective without extensive dissection of aneurysms, suggesting that basic microsurgical techniques are crucial for successful surgery. (author)

  8. Morphological parameters associated with ruptured posterior communicating aneurysms.

    Science.gov (United States)

    Ho, Allen; Lin, Ning; Charoenvimolphan, Nareerat; Stanley, Mary; Frerichs, Kai U; Day, Arthur L; Du, Rose

    2014-01-01

    The rupture risk of unruptured intracranial aneurysms is known to be dependent on the size of the aneurysm. However, the association of morphological characteristics with ruptured aneurysms has not been established in a systematic and location specific manner for the most common aneurysm locations. We evaluated posterior communicating artery (PCoA) aneurysms for morphological parameters associated with aneurysm rupture in that location. CT angiograms were evaluated to generate 3-D models of the aneurysms and surrounding vasculature. Univariate and multivariate analyses were performed to evaluate morphological parameters including aneurysm volume, aspect ratio, size ratio, distance to ICA bifurcation, aneurysm angle, vessel angles, flow angles, and vessel-to-vessel angles. From 2005-2012, 148 PCoA aneurysms were treated in a single institution. Preoperative CTAs from 63 patients (40 ruptured, 23 unruptured) were available and analyzed. Multivariate logistic regression revealed that smaller volume (p = 0.011), larger aneurysm neck diameter (0.048), and shorter ICA bifurcation to aneurysm distance (p = 0.005) were the most strongly associated with aneurysm rupture after adjusting for all other clinical and morphological variables. Multivariate subgroup analysis for patients with visualized PCoA demonstrated that larger neck diameter (p = 0.018) and shorter ICA bifurcation to aneurysm distance (p = 0.011) were significantly associated with rupture. Intracerebral hemorrhage was associated with smaller volume, larger maximum height, and smaller aneurysm angle, in addition to lateral projection, male sex, and lack of hypertension. We found that shorter ICA bifurcation to aneurysm distance is significantly associated with PCoA aneurysm rupture. This is a new physically intuitive parameter that can be measured easily and therefore be readily applied in clinical practice to aid in the evaluation of patients with PCoA aneurysms.

  9. Preliminary study of in vivo hemodynamic analysis of intracranial aneurysms using time-resolved three-dimensional phase-contrast MRI and in-house software [Presidential award proceedings

    International Nuclear Information System (INIS)

    Isoda, Haruo; Ohkura, Yasuhide; Seo, Taro

    2007-01-01

    We calculated in vivo wall shear stress (WSS) and streamlines of intracranial aneurysms and analyzed the relationships between the hemodynamics and WSS of the aneurysms using time-resolved three-dimensional (3D) phase-contrast magnetic resonance (MR) imaging (4D-Flow) and in-house software. We studied 10 subjects with 11 aneurysms. 4D-flow was performed using a 1.5T GE MR scanner with head coil. 3D time-of-flight (TOF) MR angiography was performed for geometric information. The software calculated the WSS based on interpolated shearing velocity using the data set obtained by 4D-flow near the wall and provided us with 3D streamlines. We acquired 3D streamlines and WSS distribution maps in arbitrary directions during the cardiac phase for all intracranial aneurysms, and each intracranial aneurysm in this study had at least one spiral flow. We noted lower WSS with lower flow velocities at the apex of the spiral flow. (author)

  10. Non-enhanced magnetic resonance imaging of unruptured intracranial aneurysms at 7 Tesla: Comparison with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Wrede, Karsten H.; Chen, Bixia [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); University Hospital Essen, Department of Neurosurgery, Essen (Germany); Matsushige, Toshinori [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); University Hospital Essen, Department of Neurosurgery, Essen (Germany); Hiroshima University, Department of Neurosurgery, Graduate School of Biomedical and Health Sciences, Hiroshima (Japan); Goericke, Sophia L.; Umutlu, Lale; Forsting, Michael [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Quick, Harald H. [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); University Hospital Essen, High Field and Hybrid MR Imaging, Essen (Germany); Ladd, Mark E. [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); German Cancer Research Center (DKFZ), Division of Medical Physics in Radiology (E020), Heidelberg (Germany); Johst, Soeren [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Sure, Ulrich [University Hospital Essen, Department of Neurosurgery, Essen (Germany); Schlamann, Marc [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); University Hospital Giessen, Department of Neuroradiology, Giessen (Germany)

    2017-01-15

    To prospectively evaluate non-contrast-enhanced 7-Tesla (T) MRA for delineation of unruptured intracranial aneurysms (UIAs) in comparison with DSA. Forty patients with single or multiple UIAs were enrolled in this IRB-approved trial. Sequences acquired at 7 T were TOF MRA and non-contrast-enhanced MPRAGE. All patients additionally underwent 3D rotational DSA. Two neuroradiologists individually analysed the following aneurysm and image features on a five-point scale in 2D and 3D image reconstructions: delineation of parent vessel, dome and neck; overall image quality; presence of artefacts. Interobserver accordance was assessed by the kappa coefficient. A total of 64 UIAs were detected in DSA and in all 2D and 3D MRA image reconstructions. Ratings showed comparable results for DSA and 7-T MRA when considering all image reconstructions. Highest ratings for individual image reconstructions were given for 2D MPRAGE and 3D TOF MRA. Interobserver accordance was almost perfect for the majority of ratings. This study demonstrates excellent delineation of UIAs using 7-T MRA within a clinical setting comparable to the gold standard, DSA. The combination of 7-T non-enhanced MPRAGE and TOF MRA for assessment of untreated UIAs is a promising clinical application of ultra-high-field MRA. (orig.)

  11. The Effects of Vasospasm and Re-Bleeding on the Outcome of Patients with Subarachnoid Hemorrhage from Ruptured Intracranial Aneurysm.

    Science.gov (United States)

    Filipce, Venko; Caparoski, Aleksandar

    2015-01-01

    Vasospasm and re-bleeding after subarachnoid hemorrhage from ruptured intracranial aneurysm are devastating complication that can severely affect the outcome of the patients. We are presenting a series of total number of 224 patients treated and operated at our Department due to subarachnoid hemorrhage, out of which certain number developed vasospasm and re-bleeding. We are evaluating the effect of these complications on the outcome of the patients according to the Glasgow Outcome Scale at the day of discharge. In our experience both vasospasm and ReSAH can significantly influence the outcome of patients with subarachnoid hemorrhage from ruptured intracranial aneurysm.

  12. Presence of anatomical variations of the circle of Willis in patients undergoing surgical treatment for ruptured intracranial aneurysms

    Directory of Open Access Journals (Sweden)

    Stojanović Nebojša

    2009-01-01

    Full Text Available Background/Aim. The presence of aneurysmal changes on the brain blood vessels has been subject to numerous research. This study investigated the relation between ruptured aneurysms and anatomical configuration of the Circle of Willis, with the purpose to obtain an insight into their mutual connection. Methods. The analysis included 114 patients suffering from ruptured intracranial aneurysms. Preoperative cerebral angiography was performed and compared with the intraoperative findings in order to attain a precise insight into morphological changes occurring on the circle of Willis. Results. The prevalence of asymmetrical Willis in the whole group of patients was 64%. Within the group of patients suffering from multiple aneurysms, the presence of asymmetrical Willis' circle was 75.7%. The highest incidence of the asymmetrical Circle of Willis was found among patients with aneurysmal rupture detected at the anterior comunicative artery (ACoA site (72.7% among cases with solitary and 100% among those with multiple aneurysms. Morphological changes on the A1 segment of ACoA were observed in 50 (44% cases, with higher incidence found on the right side (60%. When comparing location of ruptured aneurysms between genders, a statistically significant prevalence of the ruptured aneurisms on ACoA was present in men, whereas women showed higher incidence of ruptured aneurysms on interior cartid artery (ICA site (p < 0.01. The linkage between aneurysms with hypoplasia of the A1 segment of ACA and decreasing of the angle at which segments A1 and A2 join suggests the relationship between their onset, corresponding configuration type of Willis and subsequent hemodynamic changes. Conclusion. High incidence of asymmetry of Willis circle in the group of patients with ruptured aneurysms imply association of asymmetrical configuration and disorder in haemodynamic relations with forming and rupture of intracranial aneurysms.

  13. Cerebral magnetic resonance in-patient with metallic staple, yasargil type for hemostasia of intracranial aneurysm

    International Nuclear Information System (INIS)

    Morillo, Anibal

    1993-01-01

    Report of a case of magnetic resonance (MR) of the brain; done without complications in a patient with a yasargil intracranial aneurysm clip. The risks and precautions necessary for the performance of MR examinations in this type of patients are discussed

  14. Simultaneous or Early Sequential Rupture of Multiple Intracranial Aneurysms: A Rare and Insufficiently Understood Entity.

    Science.gov (United States)

    Hou, Kun; Zhao, Jinchuan; Zhang, Yang; Zhu, Xiaobo; Zhao, Yan; Li, Guichen

    2016-05-01

    Simultaneous or early sequential rupture of multiple intracranial aneurysms (MIAs) is encountered rarely, with no more than 10 cases having been reported. As a result of its rarity, there are a lot of questions concerning this entity need to be answered. A 67-year-old woman was admitted to the First Hospital of Jilin University (Eastern Division) from a local hospital after a sudden onset of severe headache, nausea, and vomiting. Head computed tomography (CT) at the local hospital revealed diffuse subarachnoid hemorrhage (SAH) that was concentrated predominately in the suprasellar cistern and interhemispheric fissure. During her transfer to our hospital, she experienced another episode of sudden headache. CT on admission to our hospital revealed that the SAH was increased with 2 isolated hematomas both in the interhemispheric fissure and the left paramedian frontal lobe. Further CT angiography and intraoperative findings were in favor of early sequential rupture of 2 intracranial aneurysms. To further elucidate the characteristics, mechanism, management, and prognosis of this specific entity, we conducted a comprehensive review of the literature. The mechanism of simultaneous or early sequential rupture of MIAs is still obscure. Transient elevation of blood pressure might play a role in the process, and preventing the sudden elevation of blood pressure might be beneficial for patients with aneurysmal SAH and MIAs. The management of simultaneously or early sequentially ruptured aneurysms is more complex for its difficulty in responsible aneurysm determination, urgency in treatment, toughness in intraoperative manipulation and poorness in prognosis. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Prevention and management of intraprocedural rupture of intracranial aneurysm with detachable coils during embolization

    International Nuclear Information System (INIS)

    Li, Ming-Hua; Gao, Bu-Lang; Fang, Chun; Cheng, Ying-Sheng; Li, Yong-Dong; Wang, Jue; Xu, Guo-Ping

    2006-01-01

    Intracranial aneurysm rupture during embolization with detachable coils is reportedly among the gravest of intraprocedural complications. We present here our experiences with this outcome, and a potential intervention for managing this life-threatening complication. From April 1998 to March 2005, 284 patients with cerebral aneurysms were treated with detachable coils. Intraprocedural aneurysm rupture occurred in ten patients with a history of a previously ruptured aneurysm. In the event of intraprocedural hemorrhage, we routinely performed heparin reversal with protamine sulfate. Of the 221 patients with a previously ruptured aneurysm, intraprocedural aneurysm rupture occurred in 10 (4.5%). These ruptures were caused by a microguidewire in one patient, a microcatheter in one, over-packing in two and a coil perforation in three. In the remaining three patients the ruptures were caused by both the microcatheter and the coils. Three patients died because of aneurysm re-rupture, yielding a mortality rate of 30%. One patient presented with a slight disability in the left leg and no neurological deficits were observed in the remaining six patients. Intraprocedural aneurysm rupture during embolization is a rare, but unavoidable and life-threatening event. Proper measures should be taken to reduce and improve the outcome of this tragic occurrence. The majority of patients with an intraprocedural ruptured aneurysm can survive without severe sequelae if managed appropriately. (orig.)

  16. The significant impact of framing coils on long-term outcomes in endovascular coiling for intracranial aneurysms: how to select an appropriate framing coil.

    Science.gov (United States)

    Ishida, Wataru; Sato, Masayuki; Amano, Tatsuo; Matsumaru, Yuji

    2016-09-01

    OBJECTIVE The importance of a framing coil (FC)-the first coil inserted into an aneurysm during endovascular coiling, also called a lead coil or a first coil-is recognized, but its impact on long-term outcomes, including recanalization and retreatment, is not well established. The purposes of this study were to test the hypothesis that the FC is a significant factor for aneurysmal recurrence and to provide some insights on appropriate FC selection. METHODS The authors retrospectively reviewed endovascular coiling for 280 unruptured intracranial aneurysms and gathered data on age, sex, aneurysm location, aneurysm morphology, maximal size, neck width, adjunctive techniques, recanalization, retreatment, follow-up periods, total volume packing density (VPD), volume packing density of the FC, and framing coil percentage (FCP; the percentage of FC volume in total coil volume) to clarify the associated factors for aneurysmal recurrence. RESULTS Of 236 aneurysms included in this study, 33 (14.0%) had recanalization, and 18 (7.6%) needed retreatment during a mean follow-up period of 37.7 ± 16.1 months. In multivariate analysis, aneurysm size (odds ratio [OR] = 1.29, p < 0.001), FCP < 32% (OR 3.54, p = 0.009), and VPD < 25% (OR 2.96, p = 0.015) were significantly associated with recanalization, while aneurysm size (OR 1.25, p < 0.001) and FCP < 32% (OR 6.91, p = 0.017) were significant predictors of retreatment. VPD as a continuous value or VPD with any cutoff value could not predict retreatment with statistical significance in multivariate analysis. CONCLUSIONS FCP, which is equal to the FC volume as a percentage of the total coil volume and is unaffected by the morphology of the aneurysm or the measurement error in aneurysm length, width, or height, is a novel predictor of recanalization and retreatment and is more significantly predictive of retreatment than VPD. To select FCs large enough to meet the condition of FCP ≥ 32% is a potential relevant factor for better

  17. Gene expression profile of blood cells for the prediction of delayed cerebral ischemia after intracranial aneurysm rupture: a pilot study in humans.

    Science.gov (United States)

    Baumann, Antoine; Devaux, Yvan; Audibert, Gérard; Zhang, Lu; Bracard, Serge; Colnat-Coulbois, Sophie; Klein, Olivier; Zannad, Faiez; Charpentier, Claire; Longrois, Dan; Mertes, Paul-Michel

    2013-01-01

    Delayed cerebral ischemia (DCI) is a potentially devastating complication after intracranial aneurysm rupture and its mechanisms remain poorly elucidated. Early identification of the patients prone to developing DCI after rupture may represent a major breakthrough in its prevention and treatment. The single gene approach of DCI has demonstrated interest in humans. We hypothesized that whole genome expression profile of blood cells may be useful for better comprehension and prediction of aneurysmal DCI. Over a 35-month period, 218 patients with aneurysm rupture were included in this study. DCI was defined as the occurrence of a new delayed neurological deficit occurring within 2 weeks after aneurysm rupture with evidence of ischemia either on perfusion-diffusion MRI, CT angiography or CT perfusion imaging, or with cerebral angiography. DCI patients were matched against controls based on 4 out of 5 criteria (age, sex, Fisher grade, aneurysm location and smoking status). Genome-wide expression analysis of blood cells obtained at admission was performed by microarrays. Transcriptomic analysis was performed using long oligonucleotide microarrays representing 25,000 genes. Quantitative PCR: 1 µg of total RNA extracted was reverse-transcribed, and the resulting cDNA was diluted 10-fold before performing quantitative PCR. Microarray data were first analyzed by 'Significance Analysis of Microarrays' software which includes the Benjamini correction for multiple testing. In a second step, microarray data fold change was compared using a two-tailed, paired t test. Analysis of receiver-operating characteristic (ROC) curves and the area under the ROC curves were used for prediction analysis. Logistic regression models were used to investigate the additive value of multiple biomarkers. A total of 16 patients demonstrated DCI. Significance Analysis of Microarrays software failed to retrieve significant genes, most probably because of the heterogeneity of the patients included in

  18. Morphological and Hemodynamic Discriminators for Rupture Status in Posterior Communicating Artery Aneurysms.

    Science.gov (United States)

    Lv, Nan; Wang, Chi; Karmonik, Christof; Fang, Yibin; Xu, Jinyu; Yu, Ying; Cao, Wei; Liu, Jianmin; Huang, Qinghai

    2016-01-01

    The conflicting findings of previous morphological and hemodynamic studies on intracranial aneurysm rupture may be caused by the relatively small sample sizes and the variation in location of the patient-specific aneurysm models. We aimed to determine the discriminators for aneurysm rupture status by focusing on only posterior communicating artery (PCoA) aneurysms. In 129 PCoA aneurysms (85 ruptured, 44 unruptured), clinical, morphological and hemodynamic characteristics were compared between the ruptured and unruptured cases. Multivariate logistic regression analysis was performed to determine the discriminators for rupture status of PCoA aneurysms. While univariate analyses showed that the size of aneurysm dome, aspect ratio (AR), size ratio (SR), dome-to-neck ratio (DN), inflow angle (IA), normalized wall shear stress (NWSS) and percentage of low wall shear stress area (LSA) were significantly associated with PCoA aneurysm rupture status. With multivariate analyses, significance was only retained for higher IA (OR = 1.539, p PCoA aneurysms.

  19. Dual energy CT intracranial angiography: image quality, radiation dose and initial application results

    International Nuclear Information System (INIS)

    Chai Xue; Zhang Longjiang; Lu Guangming; Zhou Changsheng

    2009-01-01

    Objective: To assess the clinical value of dual-energy intracranial CT angiography (CTA). Methods: Forty-one patients suspected of intracranial vascular diseases underwent dual-energy intracranial CT angiography, and 41 patients who underwent conventional subtraction CT were enrolled as the control group. Image quality of intracranial and skull base vessels and radiation dose between dual-energy CTA and conventional subtraction CTA were compared using two independent sample nonparametric test and independent-samples t test, respectively. Prevalence and size of lesions detected by dual-energy CTA and digital subtraction CTA were compared using paired-samples t test and Spearman correlative analysis. Results: The percentage of image quality scored 5 was 70.7% (29/41) for dual-energy CTA and 75.6% (31/41) for conventional subtraction CTA. There was no significant difference between the two groups (Z= -0.455, P=0.650). Image quality of vessels at the skull base in conventional subtraction CTA was superior to that in dual-energy CTA, especially for the petrosal and syphon segment (Z=-4.087, P=0.000). Radiation exposure of dual energy CTA and conventional CTA were (396.54±17.43) and (1090.95±114.29) mGy·cm respectively. Radiation exposure was decreased by 64% (t=-38.52, P=0.000) by dual energy CTA compared with conventional subtraction CTA. Out of the 41 patients, 19 patients were diagnosed as intracranial aneurysm, 2 patients as arteriovenous malformation (AVM), 3 patients with Moya-moya's disease, and the remaining 17 patients with negative results. Nine patients with intracranial aneurysm, 2 patients with AVM, 3 patients with Moya-moya's disease, and 2 patients with negative findings underwent DSA or operation, with concordant findings from both techniques. Diameter of aneurysm neck, long axis and minor axis by dual-energy CTA was (2.90±1.61), (5.23±1.68) and (3.83±1.69) mm, respectively; Diameter of aneurysm neck, long axis and minor axis by DSA was (2.95±1

  20. Effects of preventive surgery for unruptured intracranial aneurysms on attention, executive function, learning and memory: a prospective cohort study.

    Science.gov (United States)

    Chung, Joonho; Seok, Jeong-Ho; Kwon, Min A; Kim, Yong Bae; Joo, Jin-Yang; Hong, Chang-Ki

    2016-01-01

    We prospectively evaluated the effects of preventive surgery for unruptured intracranial aneurysms on attention, executive function, learning and memory. Between March 2012 and June 2013, 56 patients were recruited for this study. Fifty-one patients met the inclusion criteria and were enrolled. Inclusion criteria were as follows: (1) age ≤65 years and (2) planned microsurgery or endovascular surgery for unruptured intracranial aneurysm. Exclusion criteria were as follows: (1) preoperative intelligence quotient attention), WCT (executive function) and VLT (learning and memory) scores did not change significantly between the pre- and postoperative evaluations. The ACCPT, WCT, total VLT scores (verbal learning) and delayed VLT scores (memory) did not differ significantly between patients undergoing microsurgery and those undergoing endovascular surgery. However, ACCPT, WCT and delayed VLT scores decreased postoperatively in patients with leukoaraiosis on preoperative FLAIR images (OR 9.899, p = 0.041; OR 11.421, p = 0.006; OR 2.952, p = 0.024, respectively). Preventive surgery for unruptured intracranial aneurysms did not affect attention, executive function, learning or memory. However, patients with leukoaraiosis on FLAIR images might be prone to deficits in attention, executive function and memory postoperatively, whereas learning might not be affected.

  1. Intracranial arterial anatomy: evaluation by computed tomography angiography

    International Nuclear Information System (INIS)

    Regattieri, Neysa Aparecida Tinoco; Haetinger, Rainer Guilherme; Liberti, Edson Aparecido

    2010-01-01

    By many decades, the intracranial arteries study was realized exclusively by angiography through selective arterial catheterization. Nowadays, with the technologic evaluation of computerized tomography devices with multi detectors allowing acquisitions with even more thinner slices, higher speed and better resolution, it had appeared a new modality of investigation: the computed tomography angiography, less invasive and with minor morbidity than conventional arteriography. Many studies in the literature have been analyzing the sensibility of the new method for the detection of intracranial aneurysms and comparing them with the conventional arteriography. There is a necessity to recognize the normal intracranial arterial anatomy and its variations using images obtained from multiplanar reformations, in order to give important information for surgeries strategies, such as wall calcifications, aneurismatic neck position and relationships with surrounding anatomical structures. (author)

  2. Primitive experience of three dimensional multi-slice spiral CT angiography for the follow-up of intracranial aneurysm clipping

    International Nuclear Information System (INIS)

    Yang Yunjun; Chen Weijian; Hu Zhangyong; Wu Enfu; Wang Meihao; Zhuge Qichuan; Zhongming; Cheng Jingliang; Ren Cuiping; Zhang Yong

    2008-01-01

    Objective To evaluate multi-slice three-dimensional CT angiography (MS 3D-CTA) for the follow-up of intracranial aneurysm clipping. Methods: MS 3D-CTA of 16 patients with intracranial aneurysm clipping were retrospectively analyzed. The patients were scanned on a 16-slice spiral CT (GE Lightspeed pro). Volume rendering(VR), thin maximum intensity projection(thin MIP) and multi-planar reconstruction (MPR) were employed in image postprocessing in all cases. Results: There were 17 clips in the 16 patients with aneurysm clipping. Six clips were located at the posterior communicating artery, 5 at the anterior communicating artery, 4 at the middle cerebral artery, and the remaining 2 clips were located at the pericallosal artery, in 1 patient. There were no abnormalities found in the aneurysm clipping region in 7 cases by MS 3D- CTA. There were residual aneurysm in 2 cases, parent artery stenosis in 4 cases, and artery spasm in 3 eases. There was no parent artery occlusion and clip displacement in all cases. VR showed excellent 3D spacial relations between the clip and parent artery in 12 cases, and showed good relations in 3 cases. The 1 case with 2 clips in the pericallosal artery showed heavy beam-hardening artifacts. The size and shape of aneurysm clips were clearly depicted by MPR and thin MIP, while 3D spacial relation of aneurysm clip and parent artery were poorly showed. Conclusion: MS 3D-CTA is a safe and efficient method for the follow-up of intracranialaneurysm clipping. Combined VR with MPR or thin MIP can well reveal postoperative changes after aneurysm clipping. (authors)

  3. Intracranial aneurysm segmentation in 3D CT angiography: Method and quantitative validation with and without prior noise filtering

    International Nuclear Information System (INIS)

    Firouzian, Azadeh; Manniesing, Rashindra; Flach, Zwenneke H.; Risselada, Roelof; Kooten, Fop van; Sturkenboom, Miriam C.J.M.; Lugt, Aad van der; Niessen, Wiro J.

    2011-01-01

    Intracranial aneurysm volume and shape are important factors for predicting rupture risk, for pre-surgical planning and for follow-up studies. To obtain these parameters, manual segmentation can be employed; however, this is a tedious procedure, which is prone to inter- and intra-observer variability. Therefore there is a need for an automated method, which is accurate, reproducible and reliable. This study aims to develop and validate an automated method for segmenting intracranial aneurysms in Computed Tomography Angiography (CTA) data. Also, it is investigated whether prior smoothing improves segmentation robustness and accuracy. The proposed segmentation method is implemented in the level set framework, more specifically Geodesic Active Surfaces, in which a surface is evolved to capture the aneurysmal wall via an energy minimization approach. The energy term is composed of three different image features, namely; intensity, gradient magnitude and intensity variance. The method requires minimal user interaction, i.e. a single seed point inside the aneurysm needs to be placed, based on which image intensity statistics of the aneurysm are derived and used in defining the energy term. The method has been evaluated on 15 aneurysms in 11 CTA data sets by comparing the results to manual segmentations performed by two expert radiologists. Evaluation measures were Similarity Index, Average Surface Distance and Volume Difference. The results show that the automated aneurysm segmentation method is reproducible, and performs in the range of inter-observer variability in terms of accuracy. Smoothing by nonlinear diffusion with appropriate parameter settings prior to segmentation, slightly improves segmentation accuracy.

  4. Influence of hemodynamic factors on rupture of intracranial aneurysms: patient-specific 3D mirror aneurysms model computational fluid dynamics simulation.

    Science.gov (United States)

    Lu, G; Huang, L; Zhang, X L; Wang, S Z; Hong, Y; Hu, Z; Geng, D Y

    2011-08-01

    Hemodynamics factors play an important role in the rupture of cerebral aneurysms. The purpose of this study was to evaluate the impact of hemodynamic factors on the rupture of the MANs with 3D reconstruction model CFD simulation. RDSA was performed in 9 pairs of intracranial MANs. Each pair was divided into ruptured and unruptured groups. The hemodynamic factors of the aneurysms and their parent arteries were compared. There was a significant difference in the WSS at peak systole between the regions of the aneurysms and their parent arteries in the ruptured group (ie, 6.49 ± 3.48 Pa versus 8.78 ± 3.57 Pa, P =.015) but not in the unruptured group (ie, 9.80 ± 4.12 Pa versus 10.17 ± 7.48 Pa, P =.678). The proportion of the low WSS area to the whole area of the aneurysms was 12.20 ± 18.08% in the ruptured group and 3.96 ± 6.91% in the unruptured group; the difference between the 2 groups was statistically significant (P =.015). The OSI was 0.0879 ± 0.0764 in the ruptured group, which was significantly higher than that of the unruptured group (ie, 0.0183 ± 0.0191, P =.008). MANs may be a useful disease model to investigate possible causes linked to ruptured aneurysms. The ruptured aneurysms manifested lower WSS compared with their parent arteries, a higher proportion of the low WSS area to the whole area of aneurysm, and higher OSI compared with the unruptured aneurysms.

  5. Advances in open microsurgery for cerebral aneurysms.

    Science.gov (United States)

    Davies, Jason M; Lawton, Michael T

    2014-02-01

    Endovascular techniques introduced strong extrinsic forces that provoked reactive changes in aneurysm surgery. Microsurgery has become less invasive, more appealing to patients, lower risk, and efficacious for complex aneurysms, particularly those unfavorable for or failing endovascular therapy. To review specific advances in open microsurgery for aneurysms. A university-based, single-surgeon practice was examined for the use of minimally invasive craniotomies, surgical management of recurrence after coiling, the use of intracranial-intracranial bypass techniques, and cerebrovascular volume-outcome relationships. The mini-pterional, lateral supraorbital, and orbital-pterional craniotomies are minimally invasive alternatives to standard craniotomies. Mini-pterional and lateral supraorbital craniotomies were used in one-fourth of unruptured patients, increasing from 22% to 28%, whereas 15% of patients underwent orbital-pterional craniotomies and trended upward from 11% to 20%. Seventy-four patients were treated for coil recurrences (2.3% of all aneurysms) with direct clip occlusion (77%), clip occlusion after coil extraction (7%), or parent artery occlusion with bypass (16%). Intracranial-intracranial bypass (in situ bypass, reimplantation, reanastomosis, and intracranial grafts) transformed the management of giant aneurysms and made the surgical treatment of posterior inferior cerebellar artery aneurysms competitive with endovascular therapy. Centralization maximized the volume-outcome relationships observed with clipping. Aneurysm microsurgery has embraced minimalism, tailoring the exposure to the patient's anatomy with the smallest possible craniotomy that provides adequate exposure. The development of intracranial-intracranial bypasses is an important advancement that makes microsurgery a competitive option for complex and recurrent aneurysms. Trends toward centralizing aneurysm surgery in tertiary centers optimize results achievable with open microsurgery.

  6. Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

    Science.gov (United States)

    Ionita, Ciprian N; Dohatcu, Andreea; Sinelnikov, Andrey; Sherman, Jason; Keleshis, Christos; Paciorek, Ann M; Hoffmann, K R; Bednarek, D R; Rudin, S

    2009-01-01

    Image-guided endovascular intervention (EIGI), using new flow modifying endovascular devices for intracranial aneurysm treatment is an active area of stroke research. The new polyurethane-asymmetric vascular stent (P-AVS), a vascular stent partially covered with a polyurethane-based patch, is used to cover the aneurysm neck, thus occluding flow into the aneurysm. This study involves angiographic imaging of partially covered aneurysm orifices. This particular situation could occur when the vascular geometry does not allow full aneurysm coverage. Four standard in-vivo rabbit-model aneurysms were investigated; two had stent patches placed over the distal region of the aneurysm orifice while the other two had stent patches placed over the proximal region of the aneurysm orifice. Angiographic analysis was used to evaluate aneurysm blood flow before and immediately after stenting and at four-week follow-up. The treatment results were also evaluated using histology on the aneurysm dome and electron microscopy on the aneurysm neck. Post-stenting angiographic flow analysis revealed aneurysmal flow reduction in all cases with faster flow in the distally-covered case and very slow flow and prolonged pooling for proximal-coverage. At follow-up, proximally-covered aneurysms showed full dome occlusion. The electron microscopy showed a remnant neck in both distally-placed stent cases but complete coverage in the proximally-placed stent cases. Thus, direct flow (impingement jet) removal from the aneurysm dome, as indicated by angiograms in the proximally-covered case, was sufficient to cause full aneurysm healing in four weeks; however, aneurysm healing was not complete for the distally-covered case. These results support further investigations into the treatment of aneurysms by flow-modification using partial aneurysm-orifice coverage.

  7. A refined method for creating saccular aneurysms in the rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Krings, Timo [Department of Neuroradiology, University Hospital of the University of Technology Aachen, Pauwelsstrase 30, 52057, Aachen (Germany); Department of Neurosurgery, University Hospital of the University of Technology Aachen, Pauwelsstrase 30, 52057, Aachen (Germany); Moeller-Hartmann, Walter; Meetz, Alexander; Dreeskamp, Heiko; Stein, Klaus-Peter; Thron, Armin [Department of Neuroradiology, University Hospital of the University of Technology Aachen, Pauwelsstrase 30, 52057, Aachen (Germany); Hans, Franz-Josef; Thiex, Ruth; Gilsbach, Joachim M. [Department of Neurosurgery, University Hospital of the University of Technology Aachen, Pauwelsstrase 30, 52057, Aachen (Germany); Brunn, Anna [Department of Neuropathology, University Hospital of the University of Technology Aachen, Pauwelsstrase 30, 52057, Aachen (Germany); Scherer, Kira [Department of Laboratory Animal Science, University Hospital of the University of Technology Aachen, Pauwelsstrase 30, 52057, Aachen (Germany)

    2003-07-01

    We describe a refined animal model of human intracerebral aneurysms for testing endovascular devices for interventional neuroradiological procedures. Saccular aneurysms resulting from a stump of the right common carotid artery (CCA) were created in 15 New Zealand White rabbits by intraluminal incubation of elastase that was applied to the CCA after distal ligation of the CCA and proximal occlusion of the vessel using a pliable balloon. Subsequently a microcatheter was advanced to a position cranial to the balloon and the elastase was infused under fluoroscopic guidance to avoid retrograde flow to the trachea via aberrant vessels. Contrast-enhanced (CE) MRA at 1.5 T and conventional digital subtraction angiography was performed to test for aneurysm size, morphology and neck anatomy. In all 15 animals aneurysms resulted from the stump of the right CCA, ranging in size from 2.0 to 9.9 mm (mean 6.3 mm) in craniocaudal direction, 1.0 to 5.5 mm (mean 3.8 mm) in mediolateral direction and 1.0 to 3.8 mm (mean 2.4 mm) in neck diameter. Aneurysm morphology could be adequately demonstrated using CE MRA. On histological evaluation a loss of the internal elastic lamina was noted. The described method represents an easy, reliable, and reproducible method of aneurysm creation in the rabbit in an area of high shear stress. These aneurysms can be used for testing new endovascular devices for embolization of intracranial aneurysms. (orig.)

  8. A refined method for creating saccular aneurysms in the rabbit

    International Nuclear Information System (INIS)

    Krings, Timo; Moeller-Hartmann, Walter; Meetz, Alexander; Dreeskamp, Heiko; Stein, Klaus-Peter; Thron, Armin; Hans, Franz-Josef; Thiex, Ruth; Gilsbach, Joachim M.; Brunn, Anna; Scherer, Kira

    2003-01-01

    We describe a refined animal model of human intracerebral aneurysms for testing endovascular devices for interventional neuroradiological procedures. Saccular aneurysms resulting from a stump of the right common carotid artery (CCA) were created in 15 New Zealand White rabbits by intraluminal incubation of elastase that was applied to the CCA after distal ligation of the CCA and proximal occlusion of the vessel using a pliable balloon. Subsequently a microcatheter was advanced to a position cranial to the balloon and the elastase was infused under fluoroscopic guidance to avoid retrograde flow to the trachea via aberrant vessels. Contrast-enhanced (CE) MRA at 1.5 T and conventional digital subtraction angiography was performed to test for aneurysm size, morphology and neck anatomy. In all 15 animals aneurysms resulted from the stump of the right CCA, ranging in size from 2.0 to 9.9 mm (mean 6.3 mm) in craniocaudal direction, 1.0 to 5.5 mm (mean 3.8 mm) in mediolateral direction and 1.0 to 3.8 mm (mean 2.4 mm) in neck diameter. Aneurysm morphology could be adequately demonstrated using CE MRA. On histological evaluation a loss of the internal elastic lamina was noted. The described method represents an easy, reliable, and reproducible method of aneurysm creation in the rabbit in an area of high shear stress. These aneurysms can be used for testing new endovascular devices for embolization of intracranial aneurysms. (orig.)

  9. Natural history and surgical results in patients with unruptured intracranial aneurysms

    International Nuclear Information System (INIS)

    Okiyama, Koichi; Nagano, Osamu; Machida, Toshio; Serizawa, Toru; Ono, Junichi; Higuchi, Yoshinori

    2008-01-01

    The management of patients with unruptured intracranial aneurysms (UIAs) is controversial. We aimed to assess the natural history of UIAs and evaluate the surgical results. We analyzed 154 patients (181 saccular UIAs) with no history of subarachnoid hemorrhage (SAH) from a different aneurysm. Aneurysms were detected by magnetic resonance angiography (MRA) or by 3-dimensional CT angiography. Although the most frequent reason for the diagnosis was routine brain examinations of healthy patients or a vague symptom such as headache or dizziness, 15 patients were symptomatic. The natural history in patients who did not have surgery (follow-up group: 76 cases, 95 aneurysms) was assessed, and the surgical outcome of UIAs (surgical group: 78 cases, 86 aneurysms) was evaluated. Among 76 patients in the follow-up group, 7 had SAH. The mean latency period to aneurysm rupture was 3.2 months. The aneurysms with subsequent bleeding ranged from 5 to 25 mm (19.3 mm on average), whereas those without ranged from 1 to 28 mm (4.5 mm on average). The rupture rates of UIAs in anterior and posterior circulation were 6.2% and 14.3%, respectively. All ruptured cases were females. Mortality and morbidity associated with UIAs in the follow-up group were 3.9% and 3.9%, respectively. In the surgical group, no mortality was noted. Permanent morbidity associated with prospective repair of UIAs was 5.1%, although the morbidity of the patients with preoperative Rankin scores of 0 or 1 was 1.3%. Transient morbidity was observed in 6 patients (7.7%) with the size of the aneurysm 19.8 mm on average. The natural history and surgical results in patients with UIAs are modified by several factors including aneurysm size and location, the patient's age and gender, the medical status and the patient's preoperative Rankin score. The present results indicated that these factors should be considered in deciding whether to treat UIAs, and that careful assessment of the surgical benefits might be essential

  10. Methods and time schedule for follow-up of intracranial aneurysms treated with endovascular embolization: a systematic review.

    Science.gov (United States)

    Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2011-01-01

    To review the diagnostic value of angiographic methods and the optimal timetable for follow-up imaging of patients after endovascular treatment of intracranial aneurysms. A comprehensive computer-aided search for relevant primary papers was performed using the MEDLINE, PubMed, Embase, and Cochrane Collaboration database from January 1991 to March 2011. Original papers were included that reported either diagnostic value of angiographic modalities for follow-up vs. digital subtracted angiography (DSA) or comparison of aneurysm occlusion rate in delayed vs. early follow-up. The systematic review identified 35 relevant studies: 3 on the diagnostic value of three-dimensional (3D) DSA, 30 on the performance of magnetic resonance angiography (MRA), and 3 on time schedules for follow-up. 3D DSA had sensitivity of 100%, and specificity of 58.3-94.7%. Magnetic resonance angiography had sensitivity of 28.4-100%, and specificity of 50.0-100%. The proportion of aneurysms that recanalized between the early follow-up examination at 6 months and the delayed imaging at 1.5-6.0 years was 0-2.5%. Magnetic resonance angiography seems to be the best imaging method for the follow-up. In selected cases, when invasive angiography is necessary, 3D DSA should be considered to improve the diagnostic accuracy. Most patients who present with stable and adequate aneurysm occlusion at 6 months after coiling may not require further follow-up. Key words: intracranial aneurysm, embolization, coils, digital subtracted angiography, magnetic resonance, computed tomography.

  11. Usefulness of {sup 99m}Tc-HMPAO SPECT in Patients with Subarachnoid Hemorrhage due to Ruptured Intracranial Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Choi, C. W.; Lee, K. H.; Kim, J. H.; Kwark, C. E.; Lee, D. S.; Chung, J. K.; Lee, M. C.; Han, D. H.; Koh, C. S. [Seoul National University Hospital, Seoul (Korea, Republic of)

    1993-07-15

    We evaluated the usefulness of {sup 99m}Tc-HMPAO SPECT in 21 Patients with subarachnoid hemorrhage due to ruptured intracranial aneurysm and in 3 patients with unruptured intracranial aneurysm. SPECT study could detect the bilaterally hypoperfused cases in 10 patients(48%), but CT/MRI showed the bilateral abnormalities in only 3 patients(14%). The number of abnormal lesions were 56 in SPECT and 25 in CT/MRI. The lesions found in SPECT were well correlated with the neurological signs of the patients such as aphasia or hemiplegia. SPECT study during Matas test was helpful in evaluating the risk for carotid artery occlusion therapy. We thought that {sup 99m}Tc-HMPAO brain SPECT is helpful in evaluating the functional changes in patients with subarachnoid hemorrhage.

  12. Intracranial infective aneurysms presenting with haemorrhage: An analysis of angiographic findings, management and outcome

    International Nuclear Information System (INIS)

    Venkatesh, Sudhakar K.; Phadke, Rajendra V.; Kalode, Ravi R.; Kumar, Sunil; Jain, Vijendra K.

    2000-01-01

    AIM: This study is an analysis of angiographic findings in 17 patients with infective aneurysms who presented with intracranial haemorrhage and reviews the management and outcome in the context of the existing literature. MATERIALS AND METHODS: A retrospective study of infective aneurysms in 17 patients was carried out. Cranial angiography was performed in all patients. The location, size and outline of aneurysms were analysed. Ten patients were managed conservatively and six patients underwent surgery for the ruptured infective aneurysms and were followed up for a period of 35.8 months and 23 months, respectively. RESULTS: Twenty-two aneurysms were identified (five unruptured) in 17 patients. Twenty aneurysms (90.9%) were distal in location and two (9.1%) proximal. Sixty percent were in the posterior circulation with 55% in the posterior cerebral artery (PCA) territory, 27.3% in the middle cerebral artery (MCA) territory and 9.1% in the anterior cerebral artery (ACA) territory. Fourteen aneurysms were small (3-5 mm) and eight were medium sized (6-9 mm). 72.7% of aneurysms had irregular outline and 27.3% regular outline. Out of the 10 ruptured aneurysms managed conservatively, eight resolved. One patient died, presumably due to rebleed, and one had infarction due to parent vessel thrombosis. Six aneurysms were surgically managed with good results. Of the five unruptured aneurysms one was surgically managed and the remaining four conservatively managed patients did not bleed during follow-up. CONCLUSION: Patients with ruptured infective aneurysms fared well with medical management and the outcome in this series is better than that reported in literature. Patients on conservative management, however, need closer monitoring with angiographic follow-up. Active management is required with enlarging or persisting aneurysms. Venkatesh, S.K. (2000)

  13. Procedure-related haemorrhage in embolisation of intracranial aneurysms with Guglielmi detachable coils

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, B.J.; Kim, K.H. [Department of Radiology, Seoul National University College of Medicine, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Han, M.H.; Chang, K.H. [Department of Radiology, Seoul National University College of Medicine, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Clinical Research Institute, Seoul National University Hospital, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Institute of Radiation Medicine, Seoul National University Medical Research Centre, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Seoul National University College of Medicine (Korea); Oh, C.W. [Department of Neurosurgery, Seoul National University College of Medicine, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea)

    2003-08-01

    We reviewed the haemorrhagic complications of the endovascular treatment of intracranial aneurysms, in terms of frequency, pre-embolisation clinical status, clinical and radiological manifestations, management and prognosis. In 275 patients treated for 303 aneurysms over 7 years we had seven (one man and six women - 2.3%) with haemorrhage during or immediately after endovascular treatment. All procedures were performed with a standardised protocol of heparinisation and anaesthesia. Four had ruptured aneurysms, two at the tip of the basilar artery, and one ach on the internal carotid and posterior cerebral artery, treated after 12, 5, 14, and 2 days, respectively, three were in Hunt and Hess grade 2 and one in grade 1. Bleeding occurred during coiling in three, after placement of at least four coils, and during manipulation of the guidewire to enter the aneurysm in the fourth. Haemorrhage was manifest as extravasation of contrast medium, with a sudden rise in systolic blood pressure in three patients. The other three patients had unruptured aneurysms; they had stable blood pressure and angiographic findings during the procedure, but one, under sedation, had seizures immediately after insertion of four coils, and the other two had seizures, headache and vomiting on the day following the procedure. Heparin reversal with protamine sulphate was started promptly started when bleeding was detected in four patients, and the embolisation was completed with additional coils in three. Emergency ventricular drainage was performed in the two patients with ruptured aneurysm and one with an unruptured aneurysm who had abnormal neurological responses or hydrocephalus. The bleeding caused a third nerve palsy in one patient, which might have been due to ischaemia and progressively improved. (orig.)

  14. Detection of unruptured familial intracranial aneurysms by intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Berg, H.W.M. ter; Regional Hospital Almelo; Overtoom, T.M.D.; Ludwig, J.W.; Bijlsma, J.B.; Tulleken, C.A.F.; Willemse, J.

    1987-01-01

    The authors discuss the detection of intracranial aneurysms (IA) by means of intravenous digital angiography (ivDSA) in (a)symptomatic first degree relatives of families in which more than two or more individuals have IA. ivDSA is an almost noninvasive and low-risk diagnostic procedure. Screening, by means of ivDSA, of two affected families is described. In family I which includes 7 members with proven IA, ivDSA has been carried out in 36 asymptomatic individuals: in one, a 6x15 mm aneurysm was found at the left posterior communicating artery (PCoA). In family II, including one member with a proven IA and another with a subarachnoidal hemorrhage, ivDSA has been carried out in 4 members: one aneurysm with a diameter of 6 mm was found at the left PCoA. Conventional cerebral angiography (CCA) confirmed both IA's. Neurosurgical treatment followed. The advantages and disadvantages of ivDSA vs. CCA as elective screening procedure in such cases are discussed. Screening of asymptomatic first degree relatives of cases with familial IA by means of ivDSA is strongly advocated. (orig.)

  15. Technical feasibility of 2D-3D coregistration for visualization of self-expandable microstents to facilitate coil embolization of broad-based intracranial aneurysms: an in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Richter, Gregor [University of Erlangen-Nuernberg, Department of Neuroradiology, Erlangen (Germany); Kreisklinikum Siegen, Department of Radiology and Neuroradiology, Siegen (Germany); Pfister, Marcus [Siemens AG, Healthcare Sector, Forchheim (Germany); Struffert, Tobias; Engelhorn, Tobias; Doelken, Marc; Doerfler, Arnd [University of Erlangen-Nuernberg, Department of Neuroradiology, Erlangen (Germany); Spiegel, Martin; Hornegger, Joachim [University of Erlangen, Department of Informatics 5, Erlangen (Germany)

    2009-12-15

    The use of self-expandable microstents for treatment of broad-based intracranial aneurysms is widely spread. However, poor fluoroscopic visibility of the stents remains disadvantageous during the coiling procedure. Flat detector angiographic computed tomography (ACT) provides high resolution imaging of microstents even though integration of this imaging modality in the neurointerventional workflow has not been widely reported. An acrylic glass model was used to simulate the situation of a broad-based sidewall aneurysm. After insertion of a self-expandable microstent, ACT was performed. The resulting 3D dataset of the Microstent was subsequently projected into a conventional 2D fluoroscopic roadmap. This 3D visualization of the stent supported the coil embolization procedure of the in vitro aneurysm. In vitro 2D-3D coregistration with integration of 3D ACT data of a self-expandable microstent in a conventional 2D roadmap is feasible. Unsatisfying stent visibility constrains clinical cases with complex parent vessel anatomy and challenging aneurysm geometry; hence, this technique potentially may be useful in such cases. In our opinion, the clinical feasibility and utility of this new technique should be verified in a clinical aneurysm embolization study series using 2D-3D coregistration. (orig.)

  16. Technical feasibility of 2D-3D coregistration for visualization of self-expandable microstents to facilitate coil embolization of broad-based intracranial aneurysms: an in vitro study

    International Nuclear Information System (INIS)

    Richter, Gregor; Pfister, Marcus; Struffert, Tobias; Engelhorn, Tobias; Doelken, Marc; Doerfler, Arnd; Spiegel, Martin; Hornegger, Joachim

    2009-01-01

    The use of self-expandable microstents for treatment of broad-based intracranial aneurysms is widely spread. However, poor fluoroscopic visibility of the stents remains disadvantageous during the coiling procedure. Flat detector angiographic computed tomography (ACT) provides high resolution imaging of microstents even though integration of this imaging modality in the neurointerventional workflow has not been widely reported. An acrylic glass model was used to simulate the situation of a broad-based sidewall aneurysm. After insertion of a self-expandable microstent, ACT was performed. The resulting 3D dataset of the Microstent was subsequently projected into a conventional 2D fluoroscopic roadmap. This 3D visualization of the stent supported the coil embolization procedure of the in vitro aneurysm. In vitro 2D-3D coregistration with integration of 3D ACT data of a self-expandable microstent in a conventional 2D roadmap is feasible. Unsatisfying stent visibility constrains clinical cases with complex parent vessel anatomy and challenging aneurysm geometry; hence, this technique potentially may be useful in such cases. In our opinion, the clinical feasibility and utility of this new technique should be verified in a clinical aneurysm embolization study series using 2D-3D coregistration. (orig.)

  17. Outcomes of Endovascular Abdominal Aortic Aneurysm Repair in Patients with Hostile Neck Anatomy

    International Nuclear Information System (INIS)

    Choke, Edward; Munneke, Graham; Morgan, Robert; Belli, Anna-Maria; Loftus, Ian; McFarland, Robert; Loosemore, Thomas; Thompson, Matthew M.

    2006-01-01

    Purpose. The principal anatomic contraindication to endovascular aneurysm repair (EVR) is an unfavorable proximal aortic neck. With increasing experience, a greater proportion of patients with unfavorable neck anatomy are being offered EVR. This study aimed to evaluate outcomes in patients with challenging proximal aortic neck anatomy. Methods. Prospectively collected data from 147 consecutive patients who underwent EVR between December 1997 and April 2005 were supplemented with a retrospective review of medical records and radiological images. Unfavorable anatomic features were defined as neck diameter >28 mm, angulation >60 deg., circumferential thrombus >50%, and length 30 days) (p = 0.57), distal type I endoleak (p = 0.40), type III endoleak (p 0.51), secondary interventions (p = 1.0), aneurysm sac expansion (p = 0.44), or 30 day mortality (p = 0.70). The good neck group had a significantly increased incidence of type II endoleak (p = 0.023). By multivariate analysis, the incidence of intraoperative adjunctive procedures was significantly increased in the presence of severe angulation (p = 0.041, OR 3.08, 95% CI 1.05-9.04). Conclusion. Patients with severely hostile proximal aortic neck anatomy may be treated with EVR, although severely angulated necks require additional intraoperative procedures. Early outcomes are encouraging and suggest that indications for EVR may be expanded to include patients with hostile neck anatomy

  18. Endovascular Treatment of Infrarenal Abdominal Aortic Aneurysm with Short and Angulated Neck in High-Risk Patient

    Directory of Open Access Journals (Sweden)

    Stylianos Koutsias

    2013-01-01

    Full Text Available Endovascular treatment of abdominal aortic aneurysms (AAA is an established alternative to open repair. However lifelong surveillance is still required to monitor endograft function and signal the need for secondary interventions (Hobo and Buth 2006. Aortic morphology, especially related to the proximal neck, often complicates the procedure or increases the risk for late device-related complications (Hobo et al. 2007 and Chisci et al. 2009. The definition of a short and angulated neck is based on length (60° (Hobo et al. 2007 and Chisci et al. 2009. A challenging neck also offers difficulties during open repairs (OR, necessitating extensive dissection with juxta- or suprarenal aortic cross-clamping. Patients with extensive aneurysmal disease typically have more comorbidities and may not tolerate extensive surgical trauma (Sarac et al. 2002. It is, therefore, unclear whether aneurysms with a challenging proximal neck should be offered EVAR or OR (Cox et al. 2006, Choke et al. 2006, Robbins et al. 2005, Sternbergh III et al. 2002, Dillavou et al. 2003, and Greenberg et al. 2003. In our case the insertion of a thoracic endograft followed by the placement of a bifurcated aortic endograft for the treatment of a very short and severely angulated neck proved to be feasible offering acceptable duration of aneurysm exclusion. This adds up to our armamentarium in the treatment of high-risk patients, and it should be considered in emergency cases when the fenestrated and branched endografts are not available.

  19. Flow diversion in vasculitic intracranial aneurysms? Repair of giant complex cavernous carotid aneurysm in polyarteritis nodosa using Pipeline embolization devices: first reported case.

    Science.gov (United States)

    Martinez Santos, Jaime; Kaderali, Zul; Spears, Julian; Rubin, Laurence A; Marotta, Thomas R

    2016-07-01

    Intracranial aneurysms in polyarteritis nodosa (PAN) are exceedingly rare lesions with unpredictable behavior that pose real challenges to microsurgical and endovascular interventions owing to their inflammatory nature. We introduce a safe and effective alternative for treating these aneurysms using Pipeline embolization devices (PEDs). A 20-year-old man presented with diplopia, headaches, chronic abdominal pain, and weight loss. Diagnostic evaluations confirmed PAN, including bilateral giant cavernous carotid aneurysms. Cyclophosphamide and steroids achieved significant and sustained clinical improvement, with a decision to follow the aneurysms serially. Seven years later the left unruptured aneurysm enlarged, causing a sudden severe headache and a cavernous sinus syndrome. Treatment of the symptomatic aneurysm was pursued using flow diversion (PED) and the internal carotid artery was successfully reconstructed with a total of four overlapping PEDs. At 6 months follow-up, complete exclusion of the aneurysm was demonstrated, with symptomatic recovery. This is the first description of using a flow-diverting technique in an inflammatory vasculitis. In this case, PEDs not only attained a definitive closure of the aneurysm but also reconstructed the damaged and fragile arterial segment affected with vasculitis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Identification of two novel critical mutations in PCNT gene resulting in microcephalic osteodysplastic primordial dwarfism type II associated with multiple intracranial aneurysms.

    Science.gov (United States)

    Li, Fei-Feng; Wang, Xu-Dong; Zhu, Min-Wei; Lou, Zhi-Hong; Zhang, Qiong; Zhu, Chun-Yu; Feng, Hong-Lin; Lin, Zhi-Guo; Liu, Shu-Lin

    2015-12-01

    Microcephalic osteodysplastic primordial dwarfism type II (MOPD II) is a highly detrimental human autosomal inherited recessive disorder. The hallmark characteristics of this disease are intrauterine and postnatal growth restrictions, with some patients also having cerebrovascular problems such as cerebral aneurysms. The genomic basis behind most clinical features of MOPD II remains largely unclear. The aim of this work was to identify the genetic defects in a Chinese family with MOPD II associated with multiple intracranial aneurysms. The patient had typical MOPD II syndrome, with subarachnoid hemorrhage and multiple intracranial aneurysms. We identified three novel mutations in the PCNT gene, including one single base alteration (9842A>C in exon 45) and two deletions (Del-C in exon 30 and Del-16 in exon 41). The deletions were co-segregated with the affected individual in the family and were not present in the control population. Computer modeling demonstrated that the deletions may cause drastic changes on the secondary and tertiary structures, affecting the hydrophilicity and hydrophobicity of the mutant proteins. In conclusion, we identified two novel mutations in the PCNT gene associated with MOPD II and intracranial aneurysms, and the mutations were expected to alter the stability and functioning of the protein by computer modeling.

  1. [Aortic elastic properties and its clinical significance in intracranial aneurysms].

    Science.gov (United States)

    Pu, Zhao-xia; You, Xiang-dong; Weng, Wen-chao; Wang, Jian-an; Shi, Jian

    2011-09-01

    To investigate the aortic elastic properties and its clinical significance in intracranial aneurysms (IAs). One hundred and seven IAs patients (57 with hypertension) and 108 healthy subjects were recruited. The internal aortic diameters in systole and diastole were measured by the M-mode echocardiography, the aortic elasticity indexes were calculated and compared. The aortic distensibility (DIS) was lower and the aortic stiffness index (SI) was higher in IAs patients than those in controls (both P IAs patients with hypertension (IAs-HP) than those in IAs with no hypertension (P IAs patients and hypertension is closely related to the severity of aortic elasticity.

  2. Hemodynamic effect of bypass geometry on intracranial aneurysm: A numerical investigation.

    Science.gov (United States)

    Kurşun, Burak; Uğur, Levent; Keskin, Gökhan

    2018-05-01

    Hemodynamic analyzes are used in the clinical investigation and treatment of cardiovascular diseases. In the present study, the effect of bypass geometry on intracranial aneurysm hemodynamics was investigated numerically. Pressure, wall shear stress (WSS) and velocity distribution causing the aneurysm to grow and rupture were investigated and the best conditions were tried to be determined in case of bypassing between basilar (BA) and left/right posterior arteries (LPCA/RPCA) for different values of parameters. The finite volume method was used for numerical solutions and calculations were performed with the ANSYS-Fluent software. The SIMPLE algorithm was used to solve the discretized conservation equations. Second Order Upwind method was preferred for finding intermediate point values in the computational domain. As the blood flow velocity changes with time, the blood viscosity value also changes. For this reason, the Carreu model was used in determining the viscosity depending on the velocity. Numerical study results showed that when bypassed, pressure and wall shear stresses reduced in the range of 40-70% in the aneurysm. Numerical results obtained are presented in graphs including the variation of pressure, wall shear stress and velocity streamlines in the aneurysm. Considering the numerical results for all parameter values, it is seen that the most important factors affecting the pressure and WSS values in bypassing are the bypass position on the basilar artery (L b ) and the diameter of the bypass vessel (d). Pressure and wall shear stress reduced in the range of 40-70% in the aneurysm in the case of bypass for all parameters. This demonstrates that pressure and WSS values can be greatly reduced in aneurysm treatment by bypassing in cases where clipping or coil embolization methods can not be applied. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. The Preinterventional Psychiatric History as a Major Predictor for a Reduced Quality of Life After Treatment of Unruptured Intracranial Aneurysms.

    Science.gov (United States)

    Fontana, Johann; Wenz, Ralf; Groden, Christoph; Schmieder, Kirsten; Wenz, Holger

    2015-11-01

    A significantly increased rate of positive preinterventional psychiatric histories in the unruptured aneurysm collective was demonstrated previously. The current study was designed to analyze the influence of the preinterventional psychiatric status on the outcome after treatment of unruptured intracranial aneurysms. Patients treated due to meningioma World Health Organization °I and unruptured intracranial aneurysms in 2 German neurosurgical centers between 2007 and 2013 were screened for exclusion criteria including malignant/chronic diseases, recurrence of the tumor/aneurysm, and neurologic deficits among others. The preinterventional psychiatric histories and the rates of postinterventional headaches, sleeping disorders, symptoms of chronic fatigue syndrome, and quality of life (QOL) were determined by questionnaires that were mailed to the patients in a printed version. A total of 58 M patients and 45 iA patients who met the inclusion criteria returned the questionnaires; 10 M (17.2%) and 17 iA patients (37.8%) had a positive psychiatric history. The overall Incidental aneurysm collective demonstrated significantly lower overall QOL scores (P = 0.003) and significant greater rates of chronic fatigue syndrome (P = 0.009) compared with the M collective. After we excluded all patients with positive pre-interventional psychiatric histories, those differences were no longer reproducible. Subjectively, the patients did not realize any significant changes in their QOL after successful aneurysm treatment. The results of the current study demonstrate the importance of taking the preinterventional psychiatric history into considerations when evaluating the outcome after unruptured aneurysm treatment. The unfavorable outcome of the aneurysm group seems to be caused by factors that are not related the aneurysm diagnosis or treatment itself. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Peri-stent aneurysm formation following a stent implant for stenotic intracranial vertebral artery dissection: a technical report of two cases successfully treated with coil embolization.

    Science.gov (United States)

    Ishimaru, Hideki; Nakashima, Kazuaki; Takahata, Hideaki; Matsuoka, Yohjiro

    2013-02-01

    Although stenting for stenotic vertebral artery dissection (VAD) improves compromised blood flow, subsequent peri-stent aneurysm (PSA) formation is not well-known. We report two cases with PSA successfully treated with coil embolization. Three patients with stenotic intracranial VAD underwent endovascular angioplasty at our institution because they had acute infarction in posterior circulation territory and clinical evidence of hemodynamic insufficiency. In two of three patients balloon angioplasty at first session failed to relieve the stenosis, and a coronary stent was implanted. Angiography immediately after stenting showed no abnormality in case 1 and minimal slit-like projection at proximal portion of the stent in case 2. Angiography obtained 16 months after the stenting revealed PSA in case 1. In case 2, angiography performed 3 months later showed that the projection at proximal portion enlarged and formed an aneurysm outside the stent. Because follow-up angiographies showed growth of the aneurysm in both cases, endovascular aneurysmal embolization was performed. We advanced a microcatheter into the aneurysm through the strut of existing stent and delivered detachable coils into the aneurysm lumen successfully in both cases. The post-procedural course was uneventful, and complete obliteration of aneurysm was confirmed on angiography in both cases. Stenting for stenotic intracranial VAD may result in delayed PSA; therefore, follow-up angiographies would be necessary after stenting for stenotic intracranial arterial dissection. Coil embolization through the stent strut would be a solution for enlarging PSA.

  5. Reproducibility of haemodynamical simulations in a subject-specific stented aneurysm model--a report on the Virtual Intracranial Stenting Challenge 2007.

    Science.gov (United States)

    Radaelli, A G; Augsburger, L; Cebral, J R; Ohta, M; Rüfenacht, D A; Balossino, R; Benndorf, G; Hose, D R; Marzo, A; Metcalfe, R; Mortier, P; Mut, F; Reymond, P; Socci, L; Verhegghe, B; Frangi, A F

    2008-07-19

    This paper presents the results of the Virtual Intracranial Stenting Challenge (VISC) 2007, an international initiative whose aim was to establish the reproducibility of state-of-the-art haemodynamical simulation techniques in subject-specific stented models of intracranial aneurysms (IAs). IAs are pathological dilatations of the cerebral artery walls, which are associated with high mortality and morbidity rates due to subarachnoid haemorrhage following rupture. The deployment of a stent as flow diverter has recently been indicated as a promising treatment option, which has the potential to protect the aneurysm by reducing the action of haemodynamical forces and facilitating aneurysm thrombosis. The direct assessment of changes in aneurysm haemodynamics after stent deployment is hampered by limitations in existing imaging techniques and currently requires resorting to numerical simulations. Numerical simulations also have the potential to assist in the personalized selection of an optimal stent design prior to intervention. However, from the current literature it is difficult to assess the level of technological advancement and the reproducibility of haemodynamical predictions in stented patient-specific models. The VISC 2007 initiative engaged in the development of a multicentre-controlled benchmark to analyse differences induced by diverse grid generation and computational fluid dynamics (CFD) technologies. The challenge also represented an opportunity to provide a survey of available technologies currently adopted by international teams from both academic and industrial institutions for constructing computational models of stented aneurysms. The results demonstrate the ability of current strategies in consistently quantifying the performance of three commercial intracranial stents, and contribute to reinforce the confidence in haemodynamical simulation, thus taking a step forward towards the introduction of simulation tools to support diagnostics and

  6. Giant intracranial aneurysms; Magnetic resonance imaging follow-up and clinical symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Kondoh, Takeshi; Fujita, Katsuzo; Tamaki, Norihiko; Matsumoto, Satoshi [Kobe Univ. (Japan). School of Medicine; Yamashita, Haruo; Shirakata, Masaya

    1991-06-01

    Twenty-four intracranial aneurysms over 20 mm in diameter were studied with magnetic resonance (MR) imaging. MR imaging follow-up of eight cases revealed induced thrombus with homogeneous intensity and decreased size even after complete intraluminal thrombosis. Most cases demonstrated homogeneous intensity thrombus in contrast to the heterogeneous intensity of spontaneous thrombus. The clinical symptoms could not be explained retrospectively by the thrombus characteristics. Perianeurysmal high intensity, indicating cerebral edema, was detected in one case presenting with a rapid increase in size. MR imaging is useful for following these pathological intra- and perianeurysmal changes. (author).

  7. Greater rupture risk for familial as compared to sporadic unruptured intracranial aneurysms.

    Science.gov (United States)

    Broderick, Joseph P; Brown, Robert D; Sauerbeck, Laura; Hornung, Richard; Huston, John; Woo, Daniel; Anderson, Craig; Rouleau, Guy; Kleindorfer, Dawn; Flaherty, Matthew L; Meissner, Irene; Foroud, Tatiana; Moomaw, E Charles J; Connolly, E Sander

    2009-06-01

    The risk of intracranial aneurysm (IA) rupture in asymptomatic members of families who have multiple affected individuals is not known. First-degree unaffected relatives of those with a familial history of IA who had a history of smoking or hypertension but no known IA were offered cerebral MR angiography (MRA) and followed yearly as part of a National Institute of Neurological Diseases and Stroke-funded study of familial IA (Familial Intracranial Aneurysm [FIA] Study). A total of 2874 subjects from 542 FIA Study families were enrolled. After study enrollment, MRAs were performed in 548 FIA Study family members with no known history of IA. Of these 548 subjects, 113 subjects (20.6%) had 148 IAs by MRA of whom 5 subjects had IA >or=7 mm. Two subjects with an unruptured IA by MRA/CT angiography (3-mm and 4-mm anterior communicating artery) subsequently had rupture of their IA. This represents an annual rate of 1.2 ruptures per 100 subjects (1.2% per year; 95% CI, 0.14% to 4.3% per year). None of the 435 subjects with a negative MRA have had a ruptured IA. Survival curves between the MRA-positive and -negative cohorts were significantly different (P=0.004). This rupture rate of unruptured IA in the FIA Study cohort of 1.2% per year is approximately 17 times higher than the rupture rate for subjects with an unruptured IA in the International Study of Unruptured Aneurysm Study with a matched distribution of IA size and location 0.069% per year. Small unruptured IAs in patients from FIA Study families may have a higher risk of rupture than sporadic unruptured IAs of similar size, which should be considered in the management of these patients.

  8. Investigating the influence of haemodynamic stimuli on intracranial aneurysm inception.

    Science.gov (United States)

    Chen, Haoyu; Selimovic, Alisa; Thompson, Harry; Chiarini, Alessandro; Penrose, Justin; Ventikos, Yiannis; Watton, Paul N

    2013-07-01

    We propose a novel method to reconstruct the hypothetical geometry of the healthy vasculature prior to intracranial aneurysm (IA) formation: a Frenet frame is calculated along the skeletonization of the arterial geometry; upstream and downstream boundaries of the aneurysmal segment are expressed in terms of the local Frenet frame basis vectors; the hypothetical healthy geometry is then reconstructed by propagating a closed curve along the skeleton using the local Frenet frames so that the upstream boundary is smoothly morphed into the downstream boundary. This methodology takes into account the tortuosity of the arterial vasculature and requires minimal user subjectivity. The method is applied to 22 clinical cases depicting IAs. Computational fluid dynamic simulations of the vasculature without IA are performed and the haemodynamic stimuli in the location of IA formation are examined. We observe that locally elevated wall shear stress (WSS) and gradient oscillatory number (GON) are highly correlated (20/22 for WSS and 19/22 for GON) with regions susceptible to sidewall IA formation whilst haemodynamic indices associated with the oscillation of the WSS vectors have much lower correlations.

  9. Endovascular treatment of renal aneurysms: A series of 18 cases

    International Nuclear Information System (INIS)

    Sédat, J.; Chau, Y.; Baque, J.

    2012-01-01

    Purpose: To retrospectively analyze the results and complications of the endovascular treatment of 18 renal aneurysms. Methods: From 2002 to 2011, 15 patients (aged 31–76), with 18 renal aneurysms, were admitted in our institution for treatment by embolization. Except one, all were wide-necked aneurysms. One aneurysm was treated by occluding the parent artery considering its distal location; a small-necked aneurysm was treated by simple coiling, and the remaining 16 were embolized utilizing adjunctive techniques to protect the parent artery. We analyzed the rates of technical success, complication and clinical consequence, post-operative occlusion and recurrence. Results: There was a 100% technical success rate. 15 aneurysms showed a total occlusion on the post-treatment angiogram. 2 aneurysms demonstrated neck remnants, and one had an intrasaccular residual in-flow. Two minor post-operative complications were encountered but resolved over time. No delayed clinical complications were observed and the long-term angiographic follow-up demonstrated stability of the occlusion of the target renal aneurysm with no major recurrence. Conclusion: Complications of the embolization of renal aneurysms are rare. Endovascular treatment should therefore be considered at first for the treatment of renal aneurysms.

  10. Sex differences in intracranial arterial bifurcations

    DEFF Research Database (Denmark)

    Lindekleiv, Haakon M; Valen-Sendstad, Kristian; Morgan, Michael K

    2010-01-01

    Subarachnoid hemorrhage (SAH) is a serious condition, occurring more frequently in females than in males. SAH is mainly caused by rupture of an intracranial aneurysm, which is formed by localized dilation of the intracranial arterial vessel wall, usually at the apex of the arterial bifurcation. T....... The female preponderance is usually explained by systemic factors (hormonal influences and intrinsic wall weakness); however, the uneven sex distribution of intracranial aneurysms suggests a possible physiologic factor-a local sex difference in the intracranial arteries....

  11. Lipoprotein (a): a potential biological marker for unruptured intracranial aneurysms.

    Science.gov (United States)

    Phillips, J; Roberts, G; Bolger, C; el Baghdady, A; Bouchier-Hayes, D; Farrell, M; Collins, P

    1997-05-01

    The diagnosis and treatment of intracranial aneurysms (IAs) prior to rupture reduces the high morbidity and mortality associated with their occurrence. Elevated serum lipoprotein (a) [Lp(a)] level, an independent risk factor for atherogenesis, has been demonstrated in sporadic IA disease (1). The purpose of this study was to assess the degree of correlation between elevated Lp(a) levels and the occurrence of IAs in asymptomatic first degree relatives of index cases from three families exhibiting a familial tendency towards IA development. 25 family members and 41 healthy controls were screened by random serum Lp(a) sampling. All family members received 4-vessel cerebral angiography. Eleven family members were found on angiography to harbour asymptomatic aneurysms and all were successfully treated by surgery. Of these 11, ten had significantly raised serum Lp(a) levels (> 30 mg%). Fourteen family members had negative angiograms. Eight of this latter group, mean age 43.6 +/- 3.8 years, had serum Lp(a) levels above the normal range. Mean Lp(a) levels were 53.7 +/- 1.2 mg% in subjects with aneurysms compared with 22.1 +/- 1.45 mg% in subjects without demonstrable aneurysms and 10.5 +/- 0.48 mg% in the control population. The prevalence of elevated Lp(a) levels in these families and the high degree of association of raised Lp(a) levels with the presence of IAs in several family members warrants follow up of angiographically negative young subjects. We require a case-control study to establish whether particular polymorphisms at the apoprotein (a) gene level are associated with the occurrence of IAs in these families.

  12. Aneurysm in the brain

    Science.gov (United States)

    ... gov/ency/article/001414.htm Aneurysm in the brain To use the sharing features on this page, ... aneurysm occurs in a blood vessel of the brain, it is called a cerebral, or intracranial, aneurysm. ...

  13. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling

    NARCIS (Netherlands)

    Westerlaan, H. E.; Gravendeel, J.; Fiore, D.; Metzemaekers, J. D. M.; Groen, R. J. M.; Mooij, J. J. A.; Oudkerk, M.

    2007-01-01

    Introduction We sought to establish whether CT angiography (CTA) can be applied to the planning and performance of clipping or coiling in ruptured intracranial aneurysms without recourse to intraarterial digital subtraction angiography (IA-DSA). Methods Over the period April 2003 to January 2006 in

  14. The Computational Fluid Dynamics Rupture Challenge 2013--Phase II: Variability of Hemodynamic Simulations in Two Intracranial Aneurysms.

    Science.gov (United States)

    Berg, Philipp; Roloff, Christoph; Beuing, Oliver; Voss, Samuel; Sugiyama, Shin-Ichiro; Aristokleous, Nicolas; Anayiotos, Andreas S; Ashton, Neil; Revell, Alistair; Bressloff, Neil W; Brown, Alistair G; Chung, Bong Jae; Cebral, Juan R; Copelli, Gabriele; Fu, Wenyu; Qiao, Aike; Geers, Arjan J; Hodis, Simona; Dragomir-Daescu, Dan; Nordahl, Emily; Bora Suzen, Yildirim; Owais Khan, Muhammad; Valen-Sendstad, Kristian; Kono, Kenichi; Menon, Prahlad G; Albal, Priti G; Mierka, Otto; Münster, Raphael; Morales, Hernán G; Bonnefous, Odile; Osman, Jan; Goubergrits, Leonid; Pallares, Jordi; Cito, Salvatore; Passalacqua, Alberto; Piskin, Senol; Pekkan, Kerem; Ramalho, Susana; Marques, Nelson; Sanchi, Stéphane; Schumacher, Kristopher R; Sturgeon, Jess; Švihlová, Helena; Hron, Jaroslav; Usera, Gabriel; Mendina, Mariana; Xiang, Jianping; Meng, Hui; Steinman, David A; Janiga, Gábor

    2015-12-01

    With the increased availability of computational resources, the past decade has seen a rise in the use of computational fluid dynamics (CFD) for medical applications. There has been an increase in the application of CFD to attempt to predict the rupture of intracranial aneurysms, however, while many hemodynamic parameters can be obtained from these computations, to date, no consistent methodology for the prediction of the rupture has been identified. One particular challenge to CFD is that many factors contribute to its accuracy; the mesh resolution and spatial/temporal discretization can alone contribute to a variation in accuracy. This failure to identify the importance of these factors and identify a methodology for the prediction of ruptures has limited the acceptance of CFD among physicians for rupture prediction. The International CFD Rupture Challenge 2013 seeks to comment on the sensitivity of these various CFD assumptions to predict the rupture by undertaking a comparison of the rupture and blood-flow predictions from a wide range of independent participants utilizing a range of CFD approaches. Twenty-six groups from 15 countries took part in the challenge. Participants were provided with surface models of two intracranial aneurysms and asked to carry out the corresponding hemodynamics simulations, free to choose their own mesh, solver, and temporal discretization. They were requested to submit velocity and pressure predictions along the centerline and on specified planes. The first phase of the challenge, described in a separate paper, was aimed at predicting which of the two aneurysms had previously ruptured and where the rupture site was located. The second phase, described in this paper, aims to assess the variability of the solutions and the sensitivity to the modeling assumptions. Participants were free to choose boundary conditions in the first phase, whereas they were prescribed in the second phase but all other CFD modeling parameters were not

  15. Clinical and imaging features of intracranial arterial aneurysms in the pediatric population

    International Nuclear Information System (INIS)

    Abruzzo, Todd A.; Aeron, Gunjan; Jones, Blaise V.

    2013-01-01

    Intracranial arterial aneurysms (IAAs) are rare in children. Nevertheless, IAAs account for at least 10 % - 15 % of hemorrhagic strokes during the first two decades of life. Traditional vascular risk factors, which are common in the adult population, are generally absent in the pediatric population, engendering distinct modes of IAA pathogenesis. Classification of pediatric IAAs according to the pathogenetic mechanism shows eight distinct categories: idiopathic, traumatic, those due to excessive hemodynamic stress, vasculopathic, infectious, noninfectious inflammatory, oncotic, and familial. Pathogenetic mechanism is the best predictor of the clinical course of the disease, response to treatment, and long-term prognosis. The pathogenetic subtypes of pediatric IAA show characteristic and variably overlapping features. In most cases, IAAs manifesting during the first two decades of life are idiopathic. IAAs that are idiopathic, traumatic (second most common type), or due to excessive hemodynamic stresses (third most common type) account for more than 80 % of IAAs in the pediatric age group. Most of the remaining pediatric IAAs are the result of congenital cerebral aneurysmal arteriopathies or infection. Multiple IAAs are unusual in young children except in those with acquired (secondary to immune deficiency states) or congenital cerebral aneurysmal arteriopathies or infectious IAAs. (orig.)

  16. Retreatment and outcomes of recurrent intracranial vertebral artery dissecting aneurysms after stent assisted coiling: a single center experience.

    Directory of Open Access Journals (Sweden)

    Ying Song

    Full Text Available The retreatment of recurrent intracranial vertebral artery dissecting aneurysms (VADAs after stent assisted coiling (SAC has not yet been studied. The purpose of this study was to evaluate the strategies and outcomes for retreatment of recurrent VADAs after SAC.Between September 2009 and November 2013, six consecutive patients presenting with recurrent intracranial VADAs after SAC were enrolled in this study. They were all male with age ranging from 29 to 54 years (mean age, 46.2 years. The procedures of treatments and angiographic and clinical follow-up were reviewed retrospectively. Retreatment modalities were selected individually according to the characteristics of recurrence. The outcomes of retreatment were evaluated by angiographic and clinical follow-up.Six patients with recurrent intracranial VADAs after SAC were retreated, with second SAC in three patients, coil embolization, double overlapping stents placement and endovascular occlusion with aneurysm trapping in one patient, respectively. Immediate angiographic outcomes of retreatment were: complete occlusion in three patients, nearly complete occlusion in two patients, and contrast medium retention in dissecting aneurysm in one patient. All cases were technically successful. No complications related to endovascular procedures occurred. Angiographic follow-up was available in all five patients treated with second SAC or double overlapping stents, which was complete occlusion in four patients, obliteration of parent artery in one patient, showing no recurrence at 4-11 months (mean: 8.6 months. Clinical follow-up was performed in all six patients at 11-51 months after initial endovascular treatment and at 9-43 months after retreatment. The mRS of last clinical follow-up was excellent in five patients and mild disability in only one patient.Endovascular retreatment is feasible and effective for recurrent intracranial VADAs after SAC. Individualized strategies of retreatment should be

  17. Neurosurgeon academic impact is associated with clinical outcomes after clipping of ruptured intracranial aneurysms.

    Science.gov (United States)

    Alotaibi, Naif M; Ibrahim, George M; Wang, Justin; Guha, Daipayan; Mamdani, Muhammad; Schweizer, Tom A; Macdonald, R Loch

    2017-01-01

    Surgeon-dependent factors such as experience and volume are associated with patient outcomes. However, it is unknown whether a surgeon's research productivity could be related to outcomes. The main aim of this study is to investigate the association between the surgeon's academic productivity and clinical outcomes following neurosurgical clipping of ruptured aneurysms. We performed a post-hoc analysis of 3567 patients who underwent clipping of ruptured intracranial aneurysms in the randomized trials of tirilazad mesylate from 1990 to 1997. These trials included 162 centers and 156 surgeons from 21 countries. Primary and secondary outcomes were: Glasgow outcome scale score and mortality, respectively. Total publications, H-index, and graduate degrees were used as academic indicators for each surgeon. The association between outcomes and academic factors were assessed using a hierarchical logistic regression analysis, adjusting for patient covariates. Academic profiles were available for 147 surgeons, treating a total of 3307 patients. Most surgeons were from the USA (62, 42%), Canada (18, 12%), and Germany (15, 10%). On univariate analysis, the H-index correlated with better functional outcomes and lower mortality rates. In the multivariate model, patients under the care of surgeons with higher H-indices demonstrated improved neurological outcomes (p = 0.01) compared to surgeons with lower H-indices, without any significant difference in mortality. None of the other academic indicators were significantly associated with outcomes. Although prognostication following surgery for ruptured intracranial aneurysms primarily depends on clinical and radiological factors, the academic impact of the operating neurosurgeon may explain some heterogeneity in surgical outcomes.

  18. Factors Associated With Proximal Intracranial Aneurysms to Brain Arteriovenous Malformations: A Prospective Cohort Study.

    Science.gov (United States)

    Morgan, Michael Kerin; Alsahli, Khalid; Wiedmann, Markus; Assaad, Nazih N; Heller, Gillian Z

    2016-06-01

    The risk of hemorrhage from a brain arteriovenous malformation (bAVM) is increased when an associated proximal intracranial aneurysm (APIA) is present. Identifying factors that are associated with APIA may influence the prediction of hemorrhage in patients with bAVM. To identify patient- and bAVM-specific factors associated with APIA. We analyzed a prospective database of bAVMs for factors associated with the presence of APIA. Factors analyzed included age, sex, bAVM size, aneurysm size, circulation contributing to the bAVM, location of the aneurysm, deep venous drainage, and Spetzler-Ponce categories. Multiple logistic regression was performed to identify an association with APIA. Of 753 cases of bAVM with complete angiographic surveillance, 67 (9%) were found to have APIA. Older age (continuous variable; odds ratio, 1.04; 95% confidence interval, 1.02-1.05) and posterior circulation supply to the bAVM (odds ratio, 2.29; 95% confidence interval, 1.32-3.99) were factors associated with increased detection of APIA. The association of posterior circulation-supplied bAVM was not due to infratentorial bAVM location because 72% of posterior circulation APIAs were supplying supratentorial bAVM. APIAs appear to develop with time, as evident from the increased age for those with APIAs. Furthermore, they were more likely present in bAVMs supplied by the posterior circulation. This may be due to a difference in hemodynamic stress. APIA, associated proximal intracranial aneurysmbAVM, brain arteriovenous malformationDSA, digital subtraction angiographySMG, Spetzler-Martin gradeSPC, Spetzler-Ponce category.

  19. Genetic investigations on intracranial aneurysm: update and perspectives.

    Science.gov (United States)

    Bourcier, Romain; Redon, Richard; Desal, Hubert

    2015-04-01

    Detection of an intracranial aneurysm (IA) is a common finding in MRI practice. Nowadays, the incidence of unruptured IA seems to be increasing with the continuous evolution of imaging techniques. Important modifiable risk factors for SAH are well defined, but familial history of IA is the best risk marker for the presence of IA. Numerous heritable conditions are associated with IA formation but these syndromes account for less than 1% of all IAs in the population. No diagnostic test based on genetic knowledge is currently available to identify theses mutations and patients who are at higher risk for developing IAs. In the longer term, a more comprehensive understanding of independent and interdependent molecular pathways germane to IA formation and rupture may guide the physician in developing targeted therapies and optimizing prognostic risk assessment. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  20. Lessons learned from whole exome sequencing in multiplex families affected by a complex genetic disorder, intracranial aneurysm.

    Directory of Open Access Journals (Sweden)

    Janice L Farlow

    Full Text Available Genetic risk factors for intracranial aneurysm (IA are not yet fully understood. Genomewide association studies have been successful at identifying common variants; however, the role of rare variation in IA susceptibility has not been fully explored. In this study, we report the use of whole exome sequencing (WES in seven densely-affected families (45 individuals recruited as part of the Familial Intracranial Aneurysm study. WES variants were prioritized by functional prediction, frequency, predicted pathogenicity, and segregation within families. Using these criteria, 68 variants in 68 genes were prioritized across the seven families. Of the genes that were expressed in IA tissue, one gene (TMEM132B was differentially expressed in aneurysmal samples (n=44 as compared to control samples (n=16 (false discovery rate adjusted p-value=0.023. We demonstrate that sequencing of densely affected families permits exploration of the role of rare variants in a relatively common disease such as IA, although there are important study design considerations for applying sequencing to complex disorders. In this study, we explore methods of WES variant prioritization, including the incorporation of unaffected individuals, multipoint linkage analysis, biological pathway information, and transcriptome profiling. Further studies are needed to validate and characterize the set of variants and genes identified in this study.

  1. Performance of long J-shaped coils in large and giant intracranial aneurysms: an in vitro study

    International Nuclear Information System (INIS)

    Tokunaga, K.; Tanaka, N.; Sugiu, K.; Levrier, O.; Martin, J.B.; Ruefenacht, D.A.

    2002-01-01

    We evaluated the performance of long straight coils (Detach-18 trademark J-shaped coils) in large and giant in-vitro aneurysms. The coils consisted of a distal semicircular part 7 or 15 mm in diameter and a proximal 70 cm straight part having three types of stiffness: soft, standard, and stiff. We first investigated the ease of passage through a microcatheter in a realistic cerebral vessel model. Second, we made silicone models simulating lateral-type aneurysms of various spherical dome diameters (12, 15, 20 and 30 mm) and neck sizes (3-10 mm; dome-to-neck ratio approximately 3:1) and connected them to a pulsating circulatory pump. We evaluated the anchoring and folding patterns of the coils, stability of the microcatheter and coils in the aneurysm, and smoothness of delivery and retrieval of coils. Third, we compared the conformability of a coil in a large, irregular aneurysm with that of a spiral coil. The long J-shaped coils were easily advanced and retrieved through a microcatheter in a tortuous vessel model. In 12 mm spherical aneurysms, each coil made a complex framework, and knot formation or damage to the coil during withdrawal was often observed. In 15 mm aneurysms, the coils were all easily delivered and retrieved; standard-stiffness coils adapted best to this size. In 20 mm aneurysms, frameworks were less complex but still good with a standard or stiff coil, but those with soft coil were unstable and changed significantly within 3 min of detachment due to gravity and pulsatile flow. In 30 mm aneurysms, soft coils filled only the lower part during introduction, whereas a stiff coil still made a favourable framework. Conformability of a long J-shaped coil was superior to that of a spiral coil in a large, irregular aneurysm. Long J-shaped coils conform well to various configurations of large and giant aneurysms and can shorten procedures since a larger implant volume can be delivered with a single coil. Their principle of action may promote more favourable

  2. Development of a posterior cerebral artery aneurysm subsequent to occlusion of the contralateral internal carotid artery for giant cavernous aneurysm

    International Nuclear Information System (INIS)

    Wolf, R.L.; Hurst, R.W.; Imbesi, S.G.; Galetta, S.L.; Sinson, G.P.; Grossman, R.I.

    2002-01-01

    We report a case of a patient who developed a left posterior cerebral artery aneurysm 5 years after balloon occlusion of the right internal carotid artery for a giant cavernous aneurysm. The location of the new aneurysm was outside of the primary collateral pathways to the contralateral, proximally occluded, anterior circulation, illustrating the complexity of hemodynamic factors contributing to the development of intracranial saccular aneurysms. The appearance of an aneurysm in this setting supports the hypothesis that degenerative factors and hemodynamic stresses are important in the etiology of intracranial aneurysms. (orig.)

  3. Clinical outcomes of surgical clipping for intracranial aneurysms in patients with a Hunt and Hess grade 4 or 5

    Directory of Open Access Journals (Sweden)

    Yang Zhang

    2016-06-01

    Full Text Available ABSTRACT We retrospectively evaluated the records of 49 grade 4 and 5 patients with 42 intracranial aneurysms treated within 72 h of subarachnoid hemorrhage (SAH. In total, 35 patients (71% were grade 4, and 14 (29% were grade 5. A total of 42 (85% patients had one aneurysm, 6 (12% had two aneurysms, and 1 (3% had three aneurysms. Out of 49 patients, one technical (2% and one clinical (2% complication occurred at surgery. Twenty-one (43% patients recovered well, including 7 with postoperative hematoma requiring an immediate evacuation of a clot. Fourteen (29% patients had hydrocephalus and required a ventriculo-peritoneal shunt; 12 patients underwent tracheotomy postoperatively due to coma and pulmonary infection. We found that patients with Hunt and Hess grade 4 and 5 aneurysms can undergo successful neurosurgical clipping of the aneurysms after SAH. However, the morbidity and mortality rates remain high because of their poor clinical condition and a high incidence of vasospasm during treatment.

  4. Safety and Efficacy of Aneurysm Treatment with the WEB

    DEFF Research Database (Denmark)

    Pierot, L; Gubucz, I; Buhk, J H

    2017-01-01

    BACKGROUND AND PURPOSE: Flow disruption with the Woven EndoBridge (WEB) device is an innovative technique for the endovascular treatment of wide-neck bifurcation aneurysms. The initial version of the device (WEB Double-Layer) was evaluated in the WEB Clinical Assessment of IntraSaccular Aneurysm ...

  5. Celiac Trunk Embolization, as a Means of Elongating Short Distal Descending Thoracic Aortic Aneurysm Necks, Prior to Endovascular Aortic Repair

    International Nuclear Information System (INIS)

    Belenky, Alexander; Haddad, Menashe; Idov, Igor; Knizhnik, Michael; Litvin, Sergey; Bachar, Gil N.; Atar, Eli

    2009-01-01

    The purpose of this study was to report our experience in elongating short distal necks of descending thoracic aortic aneurysms (DTAAs) by coil embolization of the celiac trunk prior to endovascular aneurysm repair (EVAR). During 6 years seven patients (five men and two women; mean age, 74) who had DTAAs with short distal necks unsuitable for conventional EVAR, and well patent superior and inferior mesenteric arteries based on CT, were treated in one session with EVAR after the celiac trunk was coil embolized to elongate the neck. All patients were followed by CT every 3 months in the first year and every 6 months thereafter. Technical success was achieved in all patients, and no early or late ischemic complications were noted. No procedural complications occurred and good aneurysm sealing was obtained in all patients. Three endoleaks were identified after 3 months (one patient) and 6 months (two patients); all were treated successfully with insertion of an additional stent-graft. In patients with DTAAs who are candidates for EVAR but have short aneurysm distal necks, celiac trunk embolization-only if the superior and inferior mesenteric arteries are patent-is a good and safe way to elongate the neck and enable EVAR.

  6. Gene expression profiling reveals distinct molecular signatures associated with the rupture of intracranial aneurysm.

    Science.gov (United States)

    Nakaoka, Hirofumi; Tajima, Atsushi; Yoneyama, Taku; Hosomichi, Kazuyoshi; Kasuya, Hidetoshi; Mizutani, Tohru; Inoue, Ituro

    2014-08-01

    The rupture of intracranial aneurysm (IA) causes subarachnoid hemorrhage associated with high morbidity and mortality. We compared gene expression profiles in aneurysmal domes between unruptured IAs and ruptured IAs (RIAs) to elucidate biological mechanisms predisposing to the rupture of IA. We determined gene expression levels of 8 RIAs, 5 unruptured IAs, and 10 superficial temporal arteries with the Agilent microarrays. To explore biological heterogeneity of IAs, we classified the samples into subgroups showing similar gene expression patterns, using clustering methods. The clustering analysis identified 4 groups: superficial temporal arteries and unruptured IAs were aggregated into their own clusters, whereas RIAs segregated into 2 distinct subgroups (early and late RIAs). Comparing gene expression levels between early RIAs and unruptured IAs, we identified 430 upregulated and 617 downregulated genes in early RIAs. The upregulated genes were associated with inflammatory and immune responses and phagocytosis including S100/calgranulin genes (S100A8, S100A9, and S100A12). The downregulated genes suggest mechanical weakness of aneurysm walls. The expressions of Krüppel-like family of transcription factors (KLF2, KLF12, and KLF15), which were anti-inflammatory regulators, and CDKN2A, which was located on chromosome 9p21 that was the most consistently replicated locus in genome-wide association studies of IA, were also downregulated. We demonstrate that gene expression patterns of RIAs were different according to the age of patients. The results suggest that macrophage-mediated inflammation is a key biological pathway for IA rupture. The identified genes can be good candidates for molecular markers of rupture-prone IAs and therapeutic targets. © 2014 American Heart Association, Inc.

  7. Endovascular treatment of experimentally induced aneurysms in rabbits using stents: a feasibility study

    International Nuclear Information System (INIS)

    Hans, F.J.; Thiex, R.; Gilsbach, J.M.; Krings, T.; Moeller-Hartmann, W.; Dreeskamp, H.; Stein, K.P.; Meetz, A.; Thron, A.; Pfeffer, J.; Scherer, K.; Brunn, A.

    2003-01-01

    Although Guglielmi detachable coil (GDC) systems have been generally accepted for treatment of intracranial aneurysms, primary stenting of aneurysms using porous stents or implantation of coils after stent placement remains experimental. Testing of these new methods requires an animal model which imitates human aneurysms in size, configuration and neck morphology. We assessed in detail the technical requirements of and steps for transfemoral stent treatment of experimentally induced aneurysms at the top of the brachiocephalic trunk in rabbits. We created aneurysms in ten rabbits by distal ligation and intraluminal digestion of the right common carotid artery with elastase. We treated five animals with porous stents alone, and five with stents plus coiling via the meshes of the stent, which permitted dense packing of coils. No complications related to the procedures occurred. In all animals, even in those treated solely with porous stents, total occlusion of the aneurysm was achieved. Our animal model can be suitable for testing the biocompatibility and occlusion rate of new methods and devices for the treatment of experimental aneurysms. (orig.)

  8. Giant intracranial aneurysm with fistula to the paranasal sinuses - a case report; Aneurisma gigante intracraniano com fistula para os seios paranasais - relato de um caso

    Energy Technology Data Exchange (ETDEWEB)

    Cabral, Luciano Gusmao; Monteiro, Soraya Silveira; Rossi, Luiz Antonio; Araujo, Marcelo Antonio Nobrega; Iagarachi, Celso Kendy; Oliveira, Luiz Antonio Nunes de [Hospital do Servidor Publico Estadual de Sao Paulo, SP (Brazil). Serv. de Radiologia

    1998-09-01

    The authors present a case of giant aneurysm of internal carotid artery with extensive bone erosion, which led to a fistula to the paranasal sinuses. The clinical aspects, radiological findings and differential diagnosis of giant intracranial aneurysms are discussed. (author) 9 refs., 5 figs.

  9. Non-enhanced MR imaging of cerebral aneurysms: 7 Tesla versus 1.5 Tesla.

    Science.gov (United States)

    Wrede, Karsten H; Dammann, Philipp; Mönninghoff, Christoph; Johst, Sören; Maderwald, Stefan; Sandalcioglu, I Erol; Müller, Oliver; Özkan, Neriman; Ladd, Mark E; Forsting, Michael; Schlamann, Marc U; Sure, Ulrich; Umutlu, Lale

    2014-01-01

    To prospectively evaluate 7 Tesla time-of-flight (TOF) magnetic resonance angiography (MRA) in comparison to 1.5 Tesla TOF MRA and 7 Tesla non-contrast enhanced magnetization-prepared rapid acquisition gradient-echo (MPRAGE) for delineation of unruptured intracranial aneurysms (UIA). Sixteen neurosurgical patients (male n = 5, female n = 11) with single or multiple UIA were enrolled in this trial. All patients were accordingly examined at 7 Tesla and 1.5 Tesla MRI utilizing dedicated head coils. The following sequences were obtained: 7 Tesla TOF MRA, 1.5 Tesla TOF MRA and 7 Tesla non-contrast enhanced MPRAGE. Image analysis was performed by two radiologists with regard to delineation of aneurysm features (dome, neck, parent vessel), presence of artifacts, vessel-tissue-contrast and overall image quality. Interobserver accordance and intermethod comparisons were calculated by kappa coefficient and Lin's concordance correlation coefficient. A total of 20 intracranial aneurysms were detected in 16 patients, with two patients showing multiple aneurysms (n = 2, n = 4). Out of 20 intracranial aneurysms, 14 aneurysms were located in the anterior circulation and 6 aneurysms in the posterior circulation. 7 Tesla MPRAGE imaging was superior over 1.5 and 7 Tesla TOF MRA in the assessment of all considered aneurysm and image quality features (e.g. image quality: mean MPRAGE7T: 5.0; mean TOF7T: 4.3; mean TOF1.5T: 4.3). Ratings for 7 Tesla TOF MRA were equal or higher over 1.5 Tesla TOF MRA for all assessed features except for artifact delineation (mean TOF7T: 4.3; mean TOF1.5T 4.4). Interobserver accordance was good to excellent for most ratings. 7 Tesla MPRAGE imaging demonstrated its superiority in the detection and assessment of UIA as well as overall imaging features, offering excellent interobserver accordance and highest scores for all ratings. Hence, it may bear the potential to serve as a high-quality diagnostic tool for pretherapeutic assessment and

  10. The possibility and the countermeasure of the re-rupture within procedure in the embolization of intracranial aneurysms with Guglielmi detachable coils

    International Nuclear Information System (INIS)

    Li Minghua; Gu Binxian; Cheng Yingsheng; Fang Chun; Wang Wu; Xu Tao; Xu Shiding

    2004-01-01

    Objective: To study the possibility and the way to deal with the re-rupture within procedure for rupture aneurysms with Guglielmi detachable coil (GDC) embolization. Methods: When 159 cases with intracranial aneurysms were treated with GDC embolization, the rupture during procedure occurred in 7 cases. Of them, the re-rupture was related to microguidewire in one cases, related to coils in 3 cases, related to microcatheter in 2 cases, and related to over-packing with coils in one case. Results: A continuous packing with GDC with or without microcatheter adjustment, till a total occlusion of aneurysm, was performed in 3 cases with re-rupture related to coils and in 2 cases with re-rupture related to microcatheter. Of them, a complete recovery was acquired in 4 and a monoplegia remained in one case; Both the case with re-rupture related to microguidewire and the case with re-rupture related to over-packing with coils died due to intracerebral over-bleeding. Conclusion: It is unavoidable that the re-rupture occurred during the procedure of GDC embolization of intracranial aneurysms. Its occurrence is in inverse proportion with operator's experience. The proper choice of coils may reduce the occurrence of re-rupture related to procedure. A continuous packing with coils is possible to get a total occlusion without any sequels in re-ruptured aneurysms

  11. Difference in aneurysm characteristics between patients with familial and sporadic aneurysmal subarachnoid haemorrhage

    NARCIS (Netherlands)

    Mensing, Liselore A.; Rinkel, Gabriel J E; Vlak, Monique H M; Van Der Schaaf, Irene C.; Ruigrok, Ynte M.

    2016-01-01

    Object Patients with familial intracranial aneurysms (IA) have a higher risk of rupture than patients with sporadic IA. We compared geometric and morphological risk factors for aneurysmal rupture between patients with familial and sporadic aneurysmal subarachnoid hemorrhage (aSAH) to analyse if

  12. Progressive Occlusion of Small Saccular Aneurysms Incompletely Occluded After Stent-Assisted Coil Embolization : Analysis of Related Factors and Long-Term Outcomes.

    Science.gov (United States)

    Lim, Jeong Wook; Lee, Jeongjun; Cho, Young Dae

    2017-08-08

    Incompletely occluded aneurysms after coil embolization are subject to recanalization but occasionally progress to a totally occluded state. Deployed stents may actually promote thrombosis of coiled aneurysms. We evaluated outcomes of small aneurysms (medium was evident after stent-assisted coiling, assessing factors implicated in subsequent progressive occlusion. Between September 2012 and June 2016, a total of 463 intracranial aneurysms were treated by stent-assisted coil embolization. Of these, 132 small saccular aneurysms displayed saccular filling with contrast medium in the immediate aftermath of coiling. Progressive thrombosis was defined as complete aneurysmal occlusion at the 6‑month follow-up point. Rates of progressive occlusion and factors predisposing to this were analyzed via binary logistic regression. In 101 (76.5%) of the 132 intracranial aneurysms, complete occlusion was observed in follow-up imaging studies at 6 months. Binary logistic regression analysis indicated that progressive occlusion was linked to smaller neck diameter (odds ratio [OR] = 1.533; p = 0.003), hyperlipidemia (OR = 3.329; p = 0.036) and stent type (p = 0.031). The LVIS stent is especially susceptible to progressive thrombosis, more so than Neuroform (OR = 0.098; p = 0.008) or Enterprise (OR = 0.317; p = 0.098) stents. In 57 instances of progressive thrombosis, followed for ≥12 months (mean 25.0 ± 10.7 months), 56 (98.2%) were stable, with minor recanalization noted once (1.8%) and no major recanalization. Aneurysms associated with smaller diameter necks, hyperlipidemic states and LVIS stent deployment may be inclined to possible thrombosis, if occlusion immediately after stent-assisted coil embolization is incomplete. In such instances, excellent long-term durability is anticipated.

  13. Fluid-Structure Simulations of a Ruptured Intracranial Aneurysm: Constant versus Patient-Specific Wall Thickness

    Directory of Open Access Journals (Sweden)

    S. Voß

    2016-01-01

    Full Text Available Computational Fluid Dynamics is intensively used to deepen the understanding of aneurysm growth and rupture in order to support physicians during therapy planning. However, numerous studies considering only the hemodynamics within the vessel lumen found no satisfactory criteria for rupture risk assessment. To improve available simulation models, the rigid vessel wall assumption has been discarded in this work and patient-specific wall thickness is considered within the simulation. For this purpose, a ruptured intracranial aneurysm was prepared ex vivo, followed by the acquisition of local wall thickness using μCT. The segmented inner and outer vessel surfaces served as solid domain for the fluid-structure interaction (FSI simulation. To compare wall stress distributions within the aneurysm wall and at the rupture site, FSI computations are repeated in a virtual model using a constant wall thickness approach. Although the wall stresses obtained by the two approaches—when averaged over the complete aneurysm sac—are in very good agreement, strong differences occur in their distribution. Accounting for the real wall thickness distribution, the rupture site exhibits much higher stress values compared to the configuration with constant wall thickness. The study reveals the importance of geometry reconstruction and accurate description of wall thickness in FSI simulations.

  14. A dimensionless parameter for classifying hemodynamics in intracranial

    Science.gov (United States)

    Asgharzadeh, Hafez; Borazjani, Iman

    2015-11-01

    Rupture of an intracranial aneurysm (IA) is a disease with high rates of mortality. Given the risk associated with the aneurysm surgery, quantifying the likelihood of aneurysm rupture is essential. There are many risk factors that could be implicated in the rupture of an aneurysm. However, the most important factors correlated to the IA rupture are hemodynamic factors such as wall shear stress (WSS) and oscillatory shear index (OSI) which are affected by the IA flows. Here, we carry out three-dimensional high resolution simulations on representative IA models with simple geometries to test a dimensionless number (first proposed by Le et al., ASME J Biomech Eng, 2010), denoted as An number, to classify the flow mode. An number is defined as the ratio of the time takes the parent artery flow transports across the IA neck to the time required for vortex ring formation. Based on the definition, the flow mode is vortex if An>1 and it is cavity if AnOSI on the human subject IA. This work was supported partly by the NIH grant R03EB014860, and the computational resources were partly provided by CCR at UB. We thank Prof. Hui Meng and Dr. Jianping Xiang for providing us the database of aneurysms and helpful discussions.

  15. Treatment for spontaneous intracranial dissecting aneurysms in childhood: a retrospective study of 26 cases

    Directory of Open Access Journals (Sweden)

    Yisen Zhang

    2016-12-01

    Full Text Available Objective This study aimed to assess the clinicoradiological features and treatment outcome of intracranial dissecting aneurysms (IDAs in childhood.Methods We conducted a retrospective study of pediatric patients who were treated for spontaneous IDAs in our institute between January 2010 and December 2015. The clinical presentation, aneurysm characteristics, treatment modality, and outcome were studied. Results We studied 26 pediatric patients (mean age, 13.4 years; range, 4–18 years with 31 IDAs who comprised 6.9% of all IDA patients treated during the same period. Seventeen (65.4% patients were male and nine (34.6% were female. The incidence of large (≥10mm in size or giant aneurysms (≥25mm in size was 65.5%. Twenty-one (80.8% patients underwent endovascular or surgical treatment and five (19.2% received conservative treatment. Perioperative complications occurred in three patients, in whom two eventually recovered completely with a Glasgow Outcome Scale (GOS score of 5 and one partially recovered with a GOS score 4. Overall, 25 (96.2% patients had a favorable outcome and one (3.8% had an unfavorable outcome at a mean follow-up of 22.8 months (range, 6–60 months.Conclusions Pediatric IDAs are rare. In this series, endovascular management was a relatively safe and effective method of treatment for pediatric IDAs. However, continued follow-up is required because of the possibility of aneurysm recurrence and de novo aneurysm formation after treatment.

  16. Acute postoperative neurological deterioration associated with surgery for ruptured intracranial aneurysm: incidence, predictors, and outcomes.

    Science.gov (United States)

    Mahaney, Kelly B; Todd, Michael M; Bayman, Emine O; Torner, James C

    2012-06-01

    Subarachnoid hemorrhage (SAH) results in significant morbidity and mortality, even among patients who reach medical attention in good neurological condition. Many patients have neurological decline in the perioperative period, which contributes to long-term outcomes. The focus of this study is to characterize the incidence of, characteristics predictive of, and outcomes associated with acute postoperative neurological deterioration in patients undergoing surgery for ruptured intracranial aneurysm. The Intraoperative Hypothermia for Aneurysm Surgery Trial (IHAST) was a multicenter randomized clinical trial that enrolled 1001 patients and assesssed the efficacy of hypothermia as neuroprotection during surgery to secure a ruptured intracranial aneurysm. All patients had a radiographically confirmed SAH, were classified as World Federation of Neurosurgical Societies (WFNS) Grade I-III immediately prior to surgery, and underwent surgery to secure the ruptured aneurysm within 14 days of SAH. Neurological assessment with the National Institutes of Health Stroke Scale (NIHSS) was performed preoperatively, at 24 and 72 hours postoperatively, and at time of discharge. The primary outcome variable was a dichotomized scoring based on an IHAST version of the Glasgow Outcome Scale (GOS) in which a score of 1 represents a good outcome and a score > 1 a poor outcome, as assessed at 90-days' follow-up. Data from IHAST were analyzed for occurrence of a postoperative neurological deterioration. Preoperative and intraoperative variables were assessed for associations with occurrence of postoperative neurological deterioration. Differences in baseline, intraoperative, and postoperative variables and in outcomes between patients with and without postoperative neurological deterioration were compared with Fisher exact tests. The Wilcoxon rank-sum test was used to compare variables reported as means. Multiple logistic regression was used to adjust for covariates associated with occurrence

  17. Intracranial aneurysms--a survey of the results of surgical treatment at the Prince Henry Hospital, Sydney, 1972-1976.

    Science.gov (United States)

    Gonski, A; Gonski, L; Selecki, B R; Blum, P W; Matheson, J M

    1978-03-11

    In this paper, 124 intracranial aneurysms in 114 patients operated on during a five-year period, are reviewed, and the mortality is analysed in respect to factors of age, sex, duration of preoperative interval, site, and type of operation. A comparison with an earlier comprehensive ten-year cooperative study is attempted.

  18. Stent-assisted coil embolization of aneurysms with small parent vessels: safety and efficacy analysis.

    Science.gov (United States)

    Kühn, Anna Luisa; Hou, Samuel Y; Puri, Ajit S; Silva, Christine F; Gounis, Matthew J; Wakhloo, Ajay K

    2016-06-01

    Stent-assisted coil embolization (SACE) is a viable therapeutic approach for wide-neck intracranial aneurysms. However, it can be technically challenging in small cerebral vessels (≤2 mm). To present our experience with stents approved for SACE in aneurysms with small parent arteries. All patients who underwent stent-assisted aneurysm treatment with either a Neuroform or an Enterprise stent device at our institution between June 2006 and October 2012 were identified. Additionally, we evaluated each patient's vascular risk factors, aneurysm characteristics (ruptured vs non-ruptured, incidental finding, recanalized) and follow-up angiography data. A total of 41 patients with 44 aneurysms met our criteria, including 31 women and 10 men. Most of the aneurysms were located in the anterior circulation (75%). Stent placement in vessels 1.2-2 mm in diameter was successful in 93.2%. Thromboembolic complications occurred in 6 cases and vessel straightening was seen in 1 case only. Initial nearly complete to complete aneurysm obliteration was achieved in 88.6%. Six-month follow-up angiography showed coil compaction in three cases, one asymptomatic in-stent stenosis and stent occlusion. Twelve to 20-months' follow-up showed stable coil compaction in two patients compared with previous follow-up, and aneurysm recanalization in two patients. Twenty-four to 36-months' follow-up showed further coil compaction in one of these patients and aneurysm recanalization in a previous case of stable coil compaction on mid-term follow-up. Our results suggest that SACE of aneurysms with small parent vessels is feasible in selected cases and shows good long-term patency rates of parent arteries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. Heritability of circle of Willis variations in families with intracranial aneurysms.

    Directory of Open Access Journals (Sweden)

    Mayte Sánchez van Kammen

    Full Text Available Intracranial aneurysms more often occur in the same arterial territory within families. Several aneurysm locations are associated with specific circle of Willis variations. We investigated whether the same circle of Willis variations are more likely to occur in first-degree relatives than in unrelated individuals.We assessed four circle of Willis variations (classical, A1-asymmetry, incomplete posterior communicating artery and fetal circulation in two independent groups of families with familial aneurysms and ≥2 first-degree relatives with circle of Willis imaging on MRA/CTA. In each (index family we determined the proportion of first-degree relatives with the same circle of Willis variation as the proband and compared it to the proportion of first-degree relatives of a randomly selected unrelated (comparison family who had the same circle of Willis variation as the index family's proband. Concordance in index families and comparison families was compared with a conditional logistic events/trials model. The analysis was simulated 1001 times; we report the median concordances, odds ratios (ORs, and 95% confidence intervals (95%CI. The groups were analysed separately and together by meta-analysis.We found a higher overall concordance in circle of Willis configuration in index families than in comparison families (meta-analysis, 244 families: OR 2.2, 95%CI 1.6-3.0 mostly attributable to a higher concordance in incomplete posterior communicating artery (meta-analysis: OR 2.8, 95%CI 1.8-4.3. No association was found for the other three circle of Willis variations.In two independent groups of families with familial aneurysms, the incomplete PcomA variation occurred more often within than between families suggesting heritability of this circle of Willis variation. Further studies should investigate genetic variants associated with circle of Willis formation.

  20. NOISY INTRACRANIAL TUMORS

    NARCIS (Netherlands)

    VANDOOREN, BTH; VANBRUGGEN, AC; MOOIJ, JJA; HEW, JM; JOURNEE, HL

    1994-01-01

    Transorbital sound recordings were obtained from 21 patients with intracranial tumours, 28 patients with intracranial aneurysms and 20 control patients. The group of patients with tumours consisted of 12 patients with gliomas, of whom 6 had low-grade gliomas and 6 had high-grade gliomas, and 9

  1. Search for intracranial aneurysm susceptibility gene(s using Finnish families

    Directory of Open Access Journals (Sweden)

    Ryynänen Markku

    2002-08-01

    Full Text Available Abstract Background Cerebrovascular disease is the third leading cause of death in the United States, and about one-fourth of cerebrovascular deaths are attributed to ruptured intracranial aneurysms (IA. Epidemiological evidence suggests that IAs cluster in families, and are therefore probably genetic. Identification of individuals at risk for developing IAs by genetic tests will allow concentration of diagnostic imaging on high-risk individuals. We used model-free linkage analysis based on allele sharing with a two-stage design for a genome-wide scan to identify chromosomal regions that may harbor IA loci. Methods We previously estimated sibling relative risk in the Finnish population at between 9 and 16, and proceeded with a genome-wide scan for loci predisposing to IA. In 85 Finnish families with two or more affected members, 48 affected sibling pairs (ASPs were available for our genetic study. Power calculations indicated that 48 ASPs were adequate to identify chromosomal regions likely to harbor predisposing genes and that a liberal stage I lod score threshold of 0.8 provided a reasonable balance between detection of false positive regions and failure to detect real loci with moderate effect. Results Seven chromosomal regions exceeded the stage I lod score threshold of 0.8 and five exceeded 1.0. The most significant region, on chromosome 19q, had a maximum multipoint lod score (MLS of 2.6. Conclusions Our study provides evidence for the locations of genes predisposing to IA. Further studies are necessary to elucidate the genes and their role in the pathophysiology of IA, and to design genetic tests.

  2. True aneurysms of the posterior communicating artery: a systematic review and meta-analysis of individual patient data.

    Science.gov (United States)

    He, Wenzhuan; Gandhi, Chirag D; Quinn, John; Karimi, Reza; Prestigiacomo, Charles J

    2011-01-01

    To review and analyze systematically the reported cases of "true" posterior communicating artery (PCoA) aneurysm. A retrospective review of the published literature was performed, and a meta-analysis of individual patient data was conducted. Pooled data showed that "true" PCoA aneurysms represent about 1.3% (95% confidence interval [CI] 0.8%, 1.7%) of all intracranial aneurysms and 6.8% (95% CI 4.3%, 9.2%) of all PCoA aneurysms. Mean patient age was 53.5 years (53.5 years ± 15.4), and age range was 23-79 years. Of the 49 patients reported in the literature, 44 (89.8%) were reported as ruptured, and 4 (10.2%) were reported as unruptured. There were no significant differences in ruptured status between age (P = 0.321), left vs right aneurysm (P = 0.537), and shape of aneurysm (P = 0.408). No significant differences in complication rates were found between rupture status (P = 0.27), and operative modalities (P = 0.878). The mean ages of patients who had no complications and patients who had complications were 53 years (53 years ± 2.59) vs 53.2 years (53.2 years ± 5.02) (P = 0.972). "True" PCoA aneurysms represent about 1.3% of all intracranial aneurysms and 6.8% of all PCoA aneurysms. They are more prone to rupture compared with their counterpart junctional aneurysms. When surgical management is indicated, a good understanding of the location and configuration of the aneurysm neck before surgical treatment is critical in the successful treatment of these lesions. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Effect of metal artifact reduction software on image quality of C-arm cone-beam computed tomography during intracranial aneurysm treatment.

    Science.gov (United States)

    Enomoto, Yukiko; Yamauchi, Keita; Asano, Takahiko; Otani, Katharina; Iwama, Toru

    2018-01-01

    Background and purpose C-arm cone-beam computed tomography (CBCT) has the drawback that image quality is degraded by artifacts caused by implanted metal objects. We evaluated whether metal artifact reduction (MAR) prototype software can improve the subjective image quality of CBCT images of patients with intracranial aneurysms treated with coils or clips. Materials and methods Forty-four patients with intracranial aneurysms implanted with coils (40 patients) or clips (four patients) underwent one CBCT scan from which uncorrected and MAR-corrected CBCT image datasets were reconstructed. Three blinded readers evaluated the image quality of the image sets using a four-point scale (1: Excellent, 2: Good, 3: Poor, 4: Bad). The median scores of the three readers of uncorrected and MAR-corrected images were compared with the paired Wilcoxon signed-rank and inter-reader agreement of change scores was assessed by weighted kappa statistics. The readers also recorded new clinical findings, such as intracranial hemorrhage, air, or surrounding anatomical structures on MAR-corrected images. Results The image quality of MAR-corrected CBCT images was significantly improved compared with the uncorrected CBCT image ( p software improved image quality of CBCT images degraded by metal artifacts.

  4. The safety of vasopressor-induced hypertension in subarachnoid hemorrhage patients with coexisting unruptured, unprotected intracranial aneurysms.

    Science.gov (United States)

    Reynolds, Matthew R; Buckley, Robert T; Indrakanti, Santoshi S; Turkmani, Ali H; Oh, Gerald; Crobeddu, Emanuela; Fargen, Kyle M; El Ahmadieh, Tarek Y; Naidech, Andrew M; Amin-Hanjani, Sepideh; Lanzino, Giuseppe; Hoh, Brian L; Bendok, Bernard R; Zipfel, Gregory J

    2015-10-01

    Vasopressor-induced hypertension (VIH) is an established treatment for patients with aneurysmal subarachnoid hemorrhage (SAH) who develop vasospasm and delayed cerebral ischemia (DCI). However, the safety of VIH in patients with coincident, unruptured, unprotected intracranial aneurysms is uncertain. This retrospective multiinstitutional study identified 1) patients with aneurysmal SAH and 1 or more unruptured, unprotected aneurysms who required VIH therapy (VIH group), and 2) patients with aneurysmal SAH and 1 or more unruptured, unprotected aneurysms who did not require VIH therapy (non-VIH group). All patients had previously undergone surgical or endovascular treatment for the presumed ruptured aneurysm. Comparisons between the VIH and non-VIH patients were made in terms of the patient characteristics, clinical and radiographic severity of SAH, total number of aneurysms, number of ruptured/unruptured aneurysms, aneurysm location/size, number of unruptured and unprotected aneurysms during VIH, severity of vasospasm, degree of hypervolemia, and degree and duration of VIH therapy. For the VIH group (n = 176), 484 aneurysms were diagnosed, 231 aneurysms were treated, and 253 unruptured aneurysms were left unprotected during 1293 total days of VIH therapy (5.12 total years of VIH therapy for unruptured, unprotected aneurysms). For the non-VIH group (n = 73), 207 aneurysms were diagnosed, 93 aneurysms were treated, and 114 unruptured aneurysms were left unprotected. For the VIH and non-VIH groups, the mean sizes of the ruptured (7.2 ± 0.3 vs 7.8 ± 0.6 mm, respectively; p = 0.27) and unruptured (3.4 ± 0.2 vs 3.2 ± 0.2 mm, respectively; p = 0.40) aneurysms did not differ. The authors observed 1 new SAH from a previously unruptured, unprotected aneurysm in each group (1 of 176 vs 1 of 73 patients; p = 0.50). Baseline patient characteristics and comorbidities were similar between groups. While the degree of hypervolemia was similar between the VIH and non-VIH patients

  5. Ultra Low Density Shape Memory Polymer Foams With Tunable Physicochemical Properties for Treatment of intracranial Aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Singhal, Pooja [Texas A & M Univ., College Station, TX (United States)

    2013-12-01

    Shape memory polymers (SMPs) are a rapidly emerging class of smart materials that can be stored in a deformed temporary shape, and can actively return to their original shape upon application of an external stimulus such as heat, pH or light. This behavior is particularly advantageous for minimally invasive biomedical applications comprising embolic/regenerative scaffolds, as it enables a transcatheter delivery of the device to the target site. The focus of this work was to exploit this shape memory behavior of polyurethanes, and develop an efficient embolic SMP foam device for the treatment of intracranial aneurysms.In summary, this work reports a novel family of ultra low density polymer foams which can be delivered via a minimally invasive surgery to the aneurysm site, actuated in a controlled manner to efficiently embolize the aneurysm while promoting physiological fluid/blood flow through the reticulated/open porous structure, and eventually biodegrade leading to complete healing of the vasculature.

  6. Long-term MRA follow-up after coiling of intracranial aneurysms: impact on mood and anxiety

    International Nuclear Information System (INIS)

    Ferns, Sandra P.; Nieuwkerk, Pythia T.; Majoie, Charles B.L.M.; Rooij, Willem Jan J. van; Rinkel, Gabriel J.E.

    2011-01-01

    Magnetic resonance angiography (MRA) screening for recurrence of a coiled intracranial aneurysm and formation of new aneurysms long-term after coiling may induce anxiety and depression. In coiled patients, we evaluated effects on mood and level of anxiety from long-term follow-up MRA in comparison to general population norms. Of 162 patients participating in a long-term (>4.5 years) MRA follow-up after coiling, 120 completed the EQ-5D questionnaire, a visual analog health scale and a self-developed screening related questionnaire at the time of MRA. Three months later, the same questionnaires were completed by 100 of these 120 patients. Results were compared to general population norms adjusted for gender and age. Any problem with anxiety or depression was reported in 56 of 120 patients (47%; 95%CI38 56%) at baseline and 42 of 100 patients (42%; 95%CI32 52%) at 3 months, equally for screen-positives and -negatives. Compared to the reference population, participants scored 38% (95%CI9 67%) and 27% (95%CI4 50%) more often any problem with anxiety or depression. Three months after screening, 21% (20 of 92) of screen-negatives and 13% (one of eight) of screen-positives reported to be less afraid of subarachnoid hemorrhage (SAH) compared to before screening. One of eight screen-positives reported increased fear of SAH. Patients with coiled intracranial aneurysms participating in long-term MRA screening reported significantly more often to be anxious or depressed than a reference group. Screening did not significantly increase anxiety or depression temporarily. However, subjectively, patients did report an increase in anxiety caused by screening, which decreased after 3 months. (orig.)

  7. Long-term MRA follow-up after coiling of intracranial aneurysms: impact on mood and anxiety

    Energy Technology Data Exchange (ETDEWEB)

    Ferns, Sandra P.; Nieuwkerk, Pythia T.; Majoie, Charles B.L.M. [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Rooij, Willem Jan J. van [St. Elisabeth Ziekenhuis, Department of Radiology, Tilburg (Netherlands); Rinkel, Gabriel J.E. [University Medical Center, Department of Neurology, Rudolf Magnus Institute of Neuroscience, Utrecht (Netherlands)

    2011-05-15

    Magnetic resonance angiography (MRA) screening for recurrence of a coiled intracranial aneurysm and formation of new aneurysms long-term after coiling may induce anxiety and depression. In coiled patients, we evaluated effects on mood and level of anxiety from long-term follow-up MRA in comparison to general population norms. Of 162 patients participating in a long-term (>4.5 years) MRA follow-up after coiling, 120 completed the EQ-5D questionnaire, a visual analog health scale and a self-developed screening related questionnaire at the time of MRA. Three months later, the same questionnaires were completed by 100 of these 120 patients. Results were compared to general population norms adjusted for gender and age. Any problem with anxiety or depression was reported in 56 of 120 patients (47%; 95%CI38<->56%) at baseline and 42 of 100 patients (42%; 95%CI32<->52%) at 3 months, equally for screen-positives and -negatives. Compared to the reference population, participants scored 38% (95%CI9<->67%) and 27% (95%CI4<->50%) more often any problem with anxiety or depression. Three months after screening, 21% (20 of 92) of screen-negatives and 13% (one of eight) of screen-positives reported to be less afraid of subarachnoid hemorrhage (SAH) compared to before screening. One of eight screen-positives reported increased fear of SAH. Patients with coiled intracranial aneurysms participating in long-term MRA screening reported significantly more often to be anxious or depressed than a reference group. Screening did not significantly increase anxiety or depression temporarily. However, subjectively, patients did report an increase in anxiety caused by screening, which decreased after 3 months. (orig.)

  8. Use of the stereoscopic virtual reality display system for the detection and characterization of intracranial aneurysms: A Icomparison with conventional computed tomography workstation and 3D rotational angiography.

    Science.gov (United States)

    Liu, Xiujuan; Tao, Haiquan; Xiao, Xigang; Guo, Binbin; Xu, Shangcai; Sun, Na; Li, Maotong; Xie, Li; Wu, Changjun

    2018-07-01

    This study aimed to compare the diagnostic performance of the stereoscopic virtual reality display system with the conventional computed tomography (CT) workstation and three-dimensional rotational angiography (3DRA) for intracranial aneurysm detection and characterization, with a focus on small aneurysms and those near the bone. First, 42 patients with suspected intracranial aneurysms underwent both 256-row CT angiography (CTA) and 3DRA. Volume rendering (VR) images were captured using the conventional CT workstation. Next, VR images were transferred to the stereoscopic virtual reality display system. Two radiologists independently assessed the results that were obtained using the conventional CT workstation and stereoscopic virtual reality display system. The 3DRA results were considered as the ultimate reference standard. Based on 3DRA images, 38 aneurysms were confirmed in 42 patients. Two cases were misdiagnosed and 1 was missed when the traditional CT workstation was used. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the conventional CT workstation were 94.7%, 85.7%, 97.3%, 75%, and99.3%, respectively, on a per-aneurysm basis. The stereoscopic virtual reality display system missed a case. The sensitivity, specificity, PPV, NPV, and accuracy of the stereoscopic virtual reality display system were 100%, 85.7%, 97.4%, 100%, and 97.8%, respectively. No difference was observed in the accuracy of the traditional CT workstation, stereoscopic virtual reality display system, and 3DRA in detecting aneurysms. The stereoscopic virtual reality display system has some advantages in detecting small aneurysms and those near the bone. The virtual reality stereoscopic vision obtained through the system was found as a useful tool in intracranial aneurysm diagnosis and pre-operative 3D imaging. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. 3D cine phase-contrast MRI at 3T in intracranial aneurysms compared with patient-specific computational fluid dynamics

    NARCIS (Netherlands)

    van Ooij, P.; Schneiders, J. J.; Marquering, H. A.; Majoie, C. B.; van Bavel, E.; Nederveen, A. J.

    2013-01-01

    CFD has been proved valuable for simulating blood flow in intracranial aneurysms, which may add to better rupture risk assessment. However, CFD has drawbacks such as the sensitivity to assumptions needed for the model, which may hinder its clinical implementation. 3D PC-MR imaging is a technique

  10. Models of experimental saccular aneurysms of carotid arteries in canine

    International Nuclear Information System (INIS)

    Zhang Haixia; Cheng Yingsheng; Li Minghua

    2006-01-01

    Objective: To study the availability by making experimental saccular aneurysm models of carotid arteries in canine similar to human intracranial aneurysms. Methods: Twenty healthy canines with experimental saccular side-wall aneurysms of carotid arteries were created successfully by surgery. Results: Forty experimental saccular side-wall aneurysms of carotid arteries were created successfully with 36 aneurysms and parent arteries maintaining patency with each other and four spontaneously occluded confirmed by angiography. Model successful rate reached 90%. Conclusions: Experimental saccular side-wall aneurysms of carotid arteries in canines were one of best models created for simulating human intracranial aneurysms. (authors)

  11. DIAGNOSTIC ACCURACY OF MAGNETIC RESONANCE ANGIOGRAPHY FOR UNRUPTURED CEREBRAL ANEURYSMS IN CORRELATION WITH DIGITAL SUBTRACTION ANGIOGRAPHY

    Directory of Open Access Journals (Sweden)

    Aleksandra Aracki-Trenkić

    2015-09-01

    Full Text Available Intracranial aneurysm is a focal, abnormal dilation of an artery of the brain. Magnetic resonance angiography (MRA is a non-invasive technique for vascular imaging and is thus widely used for screening for intracranial vascular lesions. The aim of the study was to show the diagnostic accuracy of 3D Time-of-Flight (3D TOF MRA in the detection of unruptured cerebral aneurysms with the use of digital subtraction angiography (DSA as the gold standard. A total of 2.612 consecutive patients underwent 3DTOF MRA. It showed unruptured aneurysms in 94 (3.6% patients. They included 68 women and 26 men ranging in age from 29 to 76 years (mean, 52.5 years. Twenty-six of them, 20 women and 6 men, underwent DSA. The Mann-Whitney U test was used for the correlation of size. Fisher’s test was used for the correlation of location. The statistical level of significance was set at p0.05 of aneurysms between TOF MRA and DSA. MRA is an accurate and non-invasive method for diagnosis of unruptured intracranial aneurysms. The results of study show the compatibility of MRA findings, the location and the size of an aneurysm in comparison with the “gold standard” – cerebral DSA.

  12. Characteristics and Outcomes of Patients with Anterior Circulation Intracranial Aneurysm Managed with Clipping in Hospital Sungai Buloh.

    Science.gov (United States)

    Ab Ghani, Ailani; Nayan, Saiful Azli Mat; Kandasamy, Regunath; Rosman, Azmin Kas; Ghani, Abdul Rahman Izani

    2016-11-01

    The annual incidence of intracranial aneurysm in Malaysia is estimated to be 1.1-1.7 per 100,000 population based on a study done conducted in 1988. Since then, little epidemiological research has been conducted in Malaysia, and the real incidence is therefore probably unreported despite advancements in the diagnosis and treatment of this disorder. Intracranial aneurysm may be treated by microsurgical clipping or embolisation depending on its location and the surgeon's preference. This study aims to report the characteristics and outcomes of patients with a clipped anterior circulation aneurysm in Hospital Sungai Buloh. We retrospectively collected the data of patients with anterior circulation aneurysms who underwent clipping from 1 January 2013 until 30 June 2014 in Hospital Sungai Buloh. The mean age of the patients was 48.9 years old, and 56.7% of the study population were male and 63.3% were Malay. There were almost equal numbers of patients with (46.7%) and without (53.3%) co-morbidities such as hypertension and ischaemic heart disease. Half of the study population fell under Fisher grade 3 (50.0%), whereas 46.7% were Fisher grade 4. With respect to the Navarro score, 20% of patients scored 10, 16.7% scored 5 or 7, 13.3% scored 11, 10% scored 9, 6.7% scored 1 and 3.3% scored 2, 3 or 8. Most of the patients fell under grade I (33.3%) of the World Federation of Neurological Societies grading (WFNS), and the fewest number of patients were grade III (3.3%). Most (56.7%) patients had an intracranial aneurysm located at the anterior communicating artery (ACOM), followed by the anterior cerebral artery (ACA) and the middle cerebral artery (MCA) (16.7% each), the posterior communicating artery (PCOM) (6.7%) and, finally, the internal carotid artery (ICA) (3.3%). Neurological outcomes at three and six months were assessed using the Modified Rankin Scale (mRS). At three months follow-up, the majority of the participants (33.3%) scored 0 or 6, whereas at six months

  13. Outcomes and Prognostic Factors of Endovascular Abdominal Aortic Aneurysm Repair in Patients with Hostile Neck Anatomy

    International Nuclear Information System (INIS)

    Jung, Hye Doo; Lee, Yun Young; Lee, Seung Jin; Yim, Nam Yeol; Kim, Jae Kyu; Choi, Soo Jin Na; Jung, Sang Young; Chang, Nam Kyu; Lim, Jae Hoon

    2012-01-01

    To evaluate the outcomes and find the prognostic factors of endovascular abdominal aortic aneurysm repair (EVAR) in patients with hostile neck anatomy of the abdominal aorta. This study was performed on 100 patients with abdominal aneurysm who were treated with EVAR between March 2006 and December 2010. We divided the patients into two groups: good neck anatomy (GNA), and hostile neck anatomy (HNA) and then compared the primary success rate and the incidence rate of complications with EVAR between the two groups. Our aim was to determine the factors related to the complications of EVAR among HNA types. There were no significant differences of primary success rate and incidence rate of complications between the two groups. Among the types of HNA, the short neck angle [odd ratio (OR), 4.23; 95% confidence interval (CI), 1.21-18.70; p = 0.023] and large neck angle (OR, 2.58; 95% CI, 0.15-11.85; p = 0.031) showed a low primary success rate. The short neck angle (OR, 2.32; 95% CI, 1.18-12.29; p = 0.002) and large neck angle (OR, 4.67; 95% CI, 0.14-19.07; p = 0.032) showed a high incidence rate of early type 1 complication. In the case of the large neck angle (OR, 3.78; 95% CI, 0.96-20.80; p = 0.047), the large neck thrombus (OR, 2.23; 95% CI, 0.24-7.12; p = 0.035) and large neck calcification (OR, 2.50; 95% CI, 0.08-18.37; p 0.043) showed a high incidence rate of complications within a year. The results suggest that patients with hostile neck anatomy can be treated with EVAR successfully, although there was a higher incidence of complications in patients with a short neck length, severe neck angulation, circumferential thrombosis, and calcified proximal neck.

  14. Unruptured intracranial aneurysm treatment effects on cognitive function: a meta-analysis.

    Science.gov (United States)

    Bonares, Michael J; Egeto, Peter; de Oliveira Manoel, Airton Leonardo; Vesely, Kristin A; Macdonald, R Loch; Schweizer, Tom A

    2016-03-01

    The treatment of an unruptured intracranial aneurysm (UIA) is not free of morbidity and mortality, and the decision is made by weighing the risks of treatment complications against the risk of aneurysm rupture. This meta-analysis quantitatively analyzed the literature on the effects of UIA treatment on cognition. MEDLINE, Embase, and PsycInfo were systematically searched for studies that reported on the cognitive status of UIA patients before and after aneurysm treatment. The search was restricted to prospective cohort and case-control studies published between January 1, 1998, and January 1, 2013. The analyses focused on the effect of treatment on general cognitive functioning, with an emphasis on 4 specific cognitive domains: executive functions, verbal and visual memory, and visuospatial functions. Eight studies, with a total of 281 patients, were included in the meta-analysis. Treatment did not affect general cognitive functioning (effect size [ES] -0.22 [95% CI -0.78 to 0.34]). Executive functions and verbal memory domains trended toward posttreatment impairment (ES -0.46 [95% CI -0.93 to 0.01] and ES -0.31 [95% CI -1.24 to 0.61]), and performance of visual memory tasks trended toward posttreatment improvement (ES 1.48 [95% CI -0.36 to 3.31]). Lastly, treatment did not significantly affect visuospatial functions (ES -0.08 [95% CI -0.30 to 0.45]). The treatment of an UIA does not seem to affect long-term cognitive function. However, definitive conclusions were not possible due to the paucity of studies addressing this issue.

  15. Initial primary endovascular treatment in the management of ruptured intracranial aneurysms: a prospective consecutive series

    International Nuclear Information System (INIS)

    Mejdoubi, Mehdi; Cognard, Christophe; Gigaud, Michel; Tremoulet, Michel; Albucher, Jean-Francois

    2006-01-01

    From January 1998 to December 2002, endovascular treatment (EVT) was used as first intention in all patients with ruptured aneurysms. The objective of this study was to analyze the results of this therapeutic strategy. Among 401 patients admitted with a subarachnoid hemorrhage (SAH), 73 (18%) had a nonaneurysmal perimesencephalic SAH, 28 were not explored by angiography due to very poor clinical status, and 28 with aneurysmal SAH were not treated due to poor clinical status. Thus, of the 300 patients with a proven aneurysmal SAH, 272 (83%) were treated. EVT was attempted in 230 patients and was successful in 222 (82%), and clipping was performed in 50 (18%). Finally, EVT was successful in 234 aneurysms (96.7%) in 222 patients out of 242 aneurysms in 230 patients (some of the patients were treated for more than one aneurysm in the same procedure). EVT-related morbidity occurred in ten patients (4.5%) and mortality in eight (3.6%). Rate of dependency or death (modified Rankin scale 3-5) was 24.5% at 26 months. Initially, complete aneurysm occlusion was obtained in 81%, a dog ear in 3.4%, a neck remnant in 8% and incomplete occlusion in 8.1% of the patients. At follow-up (mean 26 months), the occlusion rate remained stable at 75%. This consecutive prospective series shows that EVT can be performed routinely as first-intention treatment in most aneurysmal SAH. Using this therapeutic strategy, EVT was performed in 82% of patients with long-term clinical results similar to those of the ISAT study. (orig.)

  16. The Siesta Habit is Associated with a Decreased Risk of Rupture of Intracranial Aneurysms

    Directory of Open Access Journals (Sweden)

    Huibin Kang

    2017-09-01

    Full Text Available BackgroundPrevious studies have examined an association between the siesta habit and hypertension, as well as coronary heart disease. However, the relationship between a siesta and the risk of rupture of an intracranial aneurysm (IA has not yet been established. We aimed to investigate the effects of a siesta on the risk of rupture of IAs.MethodsWe prospectively enrolled consecutive patients diagnosed with IAs at our hospital between January 2016 and December 2016. Univariate and multivariate logistic regression analysis were performed to identify independent risk factors associated with IA rupture.ResultsWe studied 581 consecutive patients with 514 unruptured and 120 ruptured aneurysms. Univariate analysis demonstrated that hypertension, hyperlipidemia, diabetes mellitus, cigarette smoking, location, size, as well as shape and aspect ratio were associated with the risk of rupture of IAs. Multivariate analysis identified hypertension [odds ratio (OR 1.68, 95% confidence interval (CI 1.03–2.73], hyperlipidemia (OR 0.25, 95% CI 0.08–0.72, current cigarette smoking ≥20 cigarettes/day (d (OR 3.48, 95% CI 1.63–7.47, siesta (siesta time <1 h, OR 0.49, 95% CI 0.24–0.98 and siesta time ≥1 h, OR 0.32, 95% CI 0.19–0.57, location of largest aneurysm on the anterior communicating and internal carotid-posterior communicating artery (PCOM (anterior communicating artery OR 16.27, 95% CI 7.40–35.79 and PCOM OR 11.21, 95% CI 5.15–24.43, and size of aneurysm ≥7 mm (OR 2.19, 95% CI 1.21–3.97 as independent strong risk factors associated with risk of aneurysm rupture.ConclusionIn the present study, we found that a habitual siesta is a new predictive factor to assess the risk of rupture of an IA. We found the siesta habit may reduce the risk of aneurysm rupture. We also found that hypertension, hyperlipidemia, cigarette smoking, location, and size of aneurysm were associated with the risk of rupture of IAs.

  17. Aneurysm shape reconstruction from biplane angiograms in the ISUIA collection

    NARCIS (Netherlands)

    Raghavan, Madhavan L; Sharda, Gaurav V; Huston, John; Mocco, J; Capuano, Ana W; Torner, James C; Saha, Punam K; Meissner, Irene; Brown, Robert D; Groen, Rob

    The International Study of Unruptured Intracranial Aneurysms (ISUIA) is an epidemiologic international study of the natural history of unruptured intracranial aneurysms that enrolled 4,060 subjects. A conventional biplane cerebral angiogram available for central review was required for enrollment

  18. Comparison of MR angiography with conventional angiography in cervical and intracranial vascular disease

    International Nuclear Information System (INIS)

    Choi, D. S.; Chang, K. H.; Jung, H. W.; Han, M. H.

    1995-01-01

    To assess the usefulness of magnetic resonance angiography (MRA) in evaluation of stenosis of carotid and large cerebral vessels and cerebral aneurysm. Twenty-seven patients with either arterial stenosis in cervical or intracranial major vessels (n = 18) or cerebral aneurysm (n = 8) or both (n 1) were examined with both MRA and conventional angiography (CA). MRA was performed with 3D TOF technique with magnetization transfer suppression at 1.5T system (Magnetom, Siemens, Germany); both intracranial MRA and cervical MRA in 16 patients, intracranial MRA only in the remaining patients. For evaluation of arterial stenosis, 32 carotid bifurcations and 383 segments of intracranial major vessels were assessed in blind fashion, and were compared with those of CA. Each arterial segment was arbitrarily classified into one of five grades (< 10, 10-49, 50-74, 75-99, 100%) for carotid bifurcation and one of four (< 10, 10-49, 50-99, 100%) for intracranial vessels. For aneurysm, its location, size shape and direction were compared. For arterial stenosis, concordance rate between MRA and CA was 88% (28/32) in carotid bifurcation and 89% (340/383) in intracranial vessels. All discordant cases were overgraded on MRA. For aneurysm, 7 of 9 were demonstrated on both MRA and CA, one of which was partially demonstrated on MRA. One of the other two patients showed aneurysm only on MRA, whereas the remaining one revealed aneurysm only on CA. MRA may be performed as a screening test for occlusive disease of cervical and major intracranial vessels and cerebral aneurysm

  19. Comparison between smaller ruptured intracranial aneurysm and larger un-ruptured intracranial aneurysm: gene expression profile analysis.

    Science.gov (United States)

    Li, Hao; Li, Haowen; Yue, Haiyan; Wang, Wen; Yu, Lanbing; ShuoWang; Cao, Yong; Zhao, Jizong

    2017-07-01

    As it grows in size, an intracranial aneurysm (IA) is prone to rupture. In this study, we compared two extreme groups of IAs, ruptured IAs (RIAs) smaller than 10 mm and un-ruptured IAs (UIAs) larger than 10 mm, to investigate the genes involved in the facilitation and prevention of IA rupture. The aneurismal walls of 6 smaller saccular RIAs (size smaller than 10 mm), 6 larger saccular UIAs (size larger than 10 mm) and 12 paired control arteries were obtained during surgery. The transcription profiles of these samples were studied by microarray analysis. RT-qPCR was used to confirm the expression of the genes of interest. In addition, functional group analysis of the differentially expressed genes was performed. Between smaller RIAs and larger UIAs, 101 genes and 179 genes were significantly over-expressed, respectively. In addition, functional group analysis demonstrated that the up-regulated genes in smaller RIAs mainly participated in the cellular response to metal ions and inorganic substances, while most of the up-regulated genes in larger UIAs were involved in inflammation and extracellular matrix (ECM) organization. Moreover, compared with control arteries, inflammation was up-regulated and muscle-related biological processes were down-regulated in both smaller RIAs and larger UIAs. The genes involved in the cellular response to metal ions and inorganic substances may facilitate the rupture of IAs. In addition, the healing process, involving inflammation and ECM organization, may protect IAs from rupture.

  20. Clipping in Awake Surgery as End-Stage in a Complex Internal Carotid Artery Aneurysm After Failure of Multimodal Endovascular and Extracranial-Intracranial Bypass Treatment.

    Science.gov (United States)

    Cannizzaro, Delia; Peschillo, Simone; Mancarella, Cristina; La Pira, Biagia; Rastelli, Emanuela; Passacantilli, Emiliano; Santoro, Antonio

    2017-06-01

    Intracranial carotid artery aneurysm can be treated via microsurgical or endovascular techniques. The optimal planning is the result of the careful patient selection through clinical, anatomic, and angiographic analysis. We present a case of ruptured internal carotid artery (ICA) aneurysm that became a complex aneurysm after failure of multi-endovascular and surgery treatment. We describe complete trapping in awake craniotomy after failure of coiling, stenting, and bypassing. ICA aneurysms could become complex aneurysms following multi-treatment failure. Endovascular approaches to treat ICA aneurysms include coiling, stenting, flow diverter stenting, and stenting-assisted coiling technique. The role of surgery remains relevant. To avoid severe neurologic deficits, recurrence, and the need of retreatment, a multidisciplinary discussion with experienced endovascular and vascular neurosurgeons is mandatory in such complex cases. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  1. Factors associated with outcomes in ruptured aneurysmal patients: Clinical Study of 80 Patients

    Directory of Open Access Journals (Sweden)

    Alfotih Gobran Taha Ahmed

    2015-03-01

    Full Text Available Background: Due to insufficient data in the literature, the optimal timing for surgical intervention for ruptured intracranial aneurysms is still controversial. Some practitioners advocate early surgery, but others not. It is important to identify other factors that can be used to predict poor prognosis in ruptured intracranial aneurysm patients. Objective: To determine the influence of timing of clipping surgery, and other factors on the outcomes of ruptured intracranial aneurysms in Hunt & Hess I~III grade patients. Method: We have performed a retrospective study involving 80 patients who were surgically treated for ruptured intracranial aneurysm between 2007 and 2012. The patient population consisted of 50(62.5% females and 30(37.5% males, with an age range of 12 to 75 years old, mean age 52.33 ± 10.63 years. We measured association between the Glasgow Outcome Scores and Sex, timing of clipping surgery, aneurysm location and pre-operative patient's neurological condition using famous Hunt and Hess grade system. Results: We did not find any correlation between the outcomes of ruptured intracranial aneurysm patients and timing (early, intermediate, late stage of clipping, sex, aneurysm location. Whereas there is a significant correlation between patients outcomes and pre-operative patient neurological condition (Hunt & Hess grade. Conclusion: Timing of Surgery (early, intermediate, late does not affect outcomes in low Hunt and Hess grade patients I~III. Whereas neurological condition (Hunt & Hess has strong impact on postoperative outcomes. Others factors like sex, Age, Aneurysm location have no effect on outcomes in ruptured intracranial aneurysms.

  2. Dutch experience with the fenestrated Anaconda endograft for short-neck infrarenal and juxtarenal abdominal aortic aneurysm repair.

    Science.gov (United States)

    Dijkstra, Martijn L; Tielliu, Ignace F J; Meerwaldt, Robbert; Pierie, Maurice; van Brussel, Jerome; Schurink, Geert Willem H; Lardenoye, Jan-Willem; Zeebregts, Clark J

    2014-08-01

    In the past decennium, the management of short-neck infrarenal and juxtarenal aortic aneurysms with fenestrated endovascular aneurysm repair (FEVAR) has been shown to be successful, with good early and midterm results. Recently, a new fenestrated device, the fenestrated Anaconda (Vascutek, Renfrewshire, Scotland), was introduced. The aim of this study was to present the current Dutch experience with this device. A prospectively held database of patients treated with the fenestrated Anaconda endograft was analyzed. Decision to treat was based on current international guidelines. Indications for FEVAR included an abdominal aortic aneurysm (AAA) with unsuitable neck anatomy for EVAR. Planning was performed on computed tomography angiography images using a three-dimensional workstation. Between May 2011 and September 2013, 25 patients were treated in eight institutions for juxtarenal (n = 23) and short-neck AAA (n = 2). Median AAA size was 61 mm (59-68.5 mm). All procedures except one were performed with bifurcated devices. A total of 56 fenestrations were incorporated, and 53 (94.6%) were successfully cannulated and stented. One patient died of bowel ischemia caused by occlusion of the superior mesenteric artery. On completion angiography, three type I endoleaks and seven type II endoleaks were observed. At 1 month of follow-up, all endoleaks had spontaneously resolved. Median follow-up was 11 months (range, 1-29 months). There were no aneurysm ruptures or aneurysm-related deaths and no reinterventions to date. Primary patency at 1 month of cannulated and stented target vessels was 96%. Initial and short-term results of FEVAR using the fenestrated Anaconda endograft are promising, with acceptable technical success and short-term complication rates. Growing experience and long-term results are needed to support these findings. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  3. Preoperative coiling of coexisting intracranial aneurysm and subsequent brain tumor surgery

    Energy Technology Data Exchange (ETDEWEB)

    Park, Keun Young; Kim, Byung Moon; Kim, Dong Joon [Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-11-15

    Few studies have investigated treatment strategies for brain tumor with a coexisting unruptured intracranial aneurysm (cUIA). The purpose of this study was to evaluate the safety and efficacy of preoperative coiling for cUIA, and subsequent brain tumor surgery. A total of 19 patients (mean age, 55.2 years; M:F = 4:15) underwent preoperative coiling for 23 cUIAs and subsequent brain tumor surgery. Primary brain tumors were meningiomas (n = 7, 36.8%), pituitary adenomas (n = 7, 36.8%), gliomas (n = 3, 15.8%), vestibular schwannoma (n = 1, 5.3%), and Rathke's cleft cyst (n = 1, 5.3%). cUIAs were located at the distal internal carotid artery (n = 9, 39.1%), anterior cerebral artery (n = 8, 34.8%), middle cerebral artery (n = 4, 17.4%), basilar artery top (n = 1, 4.3%), and posterior cerebral artery, P1 segment (n = 1, 4.3%). The outcomes of preoperative coiling of cUIA and subsequent brain tumor surgery were retrospectively evaluated. Single-microcatheter technique was used in 13 cases (56.5%), balloon-assisted in 4 cases (17.4%), double-microcatheter in 4 cases (17.4%), and stent-assisted in 2 cases (8.7%). Complete cUIA occlusion was achieved in 18 cases (78.3%), while residual neck occurred in 5 cases (21.7%). The only coiling-related complication was 1 transient ischemic attack (5.3%). Neurological deterioration did not occur in any patient during the period between coiling and tumor surgery. At the latest clinical follow-up (mean, 29 months; range, 2-120 months), 15 patients (78.9%) had favorable outcomes (modified Rankin Scale, 0-2), while 4 patients (21.1%) had unfavorable outcomes due to consequences of brain tumor surgery. Preoperative coiling and subsequent tumor surgery was safe and effective, making it a reasonable treatment option for patients with brain tumor and cUIA.

  4. Preoperative coiling of coexisting intracranial aneurysm and subsequent brain tumor surgery

    International Nuclear Information System (INIS)

    Park, Keun Young; Kim, Byung Moon; Kim, Dong Joon

    2016-01-01

    Few studies have investigated treatment strategies for brain tumor with a coexisting unruptured intracranial aneurysm (cUIA). The purpose of this study was to evaluate the safety and efficacy of preoperative coiling for cUIA, and subsequent brain tumor surgery. A total of 19 patients (mean age, 55.2 years; M:F = 4:15) underwent preoperative coiling for 23 cUIAs and subsequent brain tumor surgery. Primary brain tumors were meningiomas (n = 7, 36.8%), pituitary adenomas (n = 7, 36.8%), gliomas (n = 3, 15.8%), vestibular schwannoma (n = 1, 5.3%), and Rathke's cleft cyst (n = 1, 5.3%). cUIAs were located at the distal internal carotid artery (n = 9, 39.1%), anterior cerebral artery (n = 8, 34.8%), middle cerebral artery (n = 4, 17.4%), basilar artery top (n = 1, 4.3%), and posterior cerebral artery, P1 segment (n = 1, 4.3%). The outcomes of preoperative coiling of cUIA and subsequent brain tumor surgery were retrospectively evaluated. Single-microcatheter technique was used in 13 cases (56.5%), balloon-assisted in 4 cases (17.4%), double-microcatheter in 4 cases (17.4%), and stent-assisted in 2 cases (8.7%). Complete cUIA occlusion was achieved in 18 cases (78.3%), while residual neck occurred in 5 cases (21.7%). The only coiling-related complication was 1 transient ischemic attack (5.3%). Neurological deterioration did not occur in any patient during the period between coiling and tumor surgery. At the latest clinical follow-up (mean, 29 months; range, 2-120 months), 15 patients (78.9%) had favorable outcomes (modified Rankin Scale, 0-2), while 4 patients (21.1%) had unfavorable outcomes due to consequences of brain tumor surgery. Preoperative coiling and subsequent tumor surgery was safe and effective, making it a reasonable treatment option for patients with brain tumor and cUIA

  5. Successful Retreatment of Recurrent Intracranial Vertebral Artery Dissecting Aneurysms After Stent-Assisted Coil Embolization: A Self-Controlled Hemodynamic Analysis.

    Science.gov (United States)

    Liu, Jian; Jing, Linkai; Zhang, Ying; Song, Ying; Wang, Yang; Li, Chuanhui; Wang, Yanmin; Mu, Shiqing; Paliwal, Nikhil; Meng, Hui; Linfante, Italo; Yang, Xinjian

    2017-01-01

    Intracranial vertebral artery dissecting aneurysms (VADAs) tend to recur despite successful stent-assisted coil embolization (SACE). Hemodynamics is useful in evaluating aneurysmal formation, growth, and rupture. Our aim was to evaluate the hemodynamic patterns of the recurrence of VADA. Between September 2009 and November 2013, all consecutive patients with recurrent VADAs after SACE in our institutions were enrolled. Recurrence was defined as recanalization and/or regrowth. We assessed the hemodynamic alterations in wall shear stress (WSS) and velocity after the initial SACE and subsequently after retreatment of the aneurysms that recurred. Five patients were included. After the initial treatment, 3 patients showed recanalization and 2 showed regrowth. In the 2 patients with regrowth, the 2 original aneurysms maintained complete occlusion; however, de novo aneurysm regrowth was confirmed near the previous site. Compared with 3 recanalized aneurysms, the completely occluded aneurysms showed high mean reductions in velocity and WSS after initial treatment (velocity, 77.6% vs. 57.7%; WSS, 74.2% vs. 52.4%); however, WSS remained high at the region near the previous lesion where the new aneurysm originated. After the second retreatment, there was no recurrence in any patient. Compared with the 3 aneurysms that recanalized, the 4 aneurysms that maintained complete occlusion showed higher reductions in velocity (62.9%) and WSS (71.1%). Our series indicated that hemodynamics might have an important role in recurrence of VADAs. After endovascular treatment, sufficient hemodynamic reduction in aneurysm dome, orifice, and parent vessel may be one of the key factors for preventing recurrence in VADAs. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

    International Nuclear Information System (INIS)

    Saha, Prakash; Hughes, John; Patel, Ashish S.; Donati, Tommaso; Sallam, Morad; Patel, Sanjay D.; Bell, Rachel E.; Katsanos, Konstantinos; Modarai, Bijan; Zayed, Hany A.

    2015-01-01

    PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities

  7. Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Prakash, E-mail: prakash.2.saha@kcl.ac.uk; Hughes, John, E-mail: johnhughes387@rocketmail.com; Patel, Ashish S., E-mail: ashish.s.patel@kcl.ac.uk; Donati, Tommaso, E-mail: tommaso.donati@gstt.nhs.uk; Sallam, Morad, E-mail: morad.sallam@gstt.nhs.uk; Patel, Sanjay D., E-mail: sanjay.patel@gstt.nhs.uk; Bell, Rachel E. [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Modarai, Bijan, E-mail: bijan.modarai@kcl.ac.uk; Zayed, Hany A., E-mail: hany.zayed@gstt.nhs.uk [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2015-08-15

    PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities.

  8. Sex differences in intracranial arterial bifurcations

    DEFF Research Database (Denmark)

    Lindekleiv, Haakon M; Valen-Sendstad, Kristian; Morgan, Michael K

    2010-01-01

    . The female preponderance is usually explained by systemic factors (hormonal influences and intrinsic wall weakness); however, the uneven sex distribution of intracranial aneurysms suggests a possible physiologic factor-a local sex difference in the intracranial arteries....

  9. The non-invasive detection of intracranial aneurysms: are neuroradiologists any better than other observers?

    Energy Technology Data Exchange (ETDEWEB)

    White, Philip M. [University Department of Neurosurgery and Department of Neuroradiology, Institute of Neurological Sciences, Southern General Hospital, Glasgow G52 4TF (United Kingdom); Department of Clinical Neurosciences, University of Edinburgh, Western General Hospital, Crewe Road, Edinburgh EH4 2XU (United Kingdom); Wardlaw, Joanna M. [Department of Clinical Neurosciences, University of Edinburgh, Western General Hospital, Crewe Road, Edinburgh EH4 2XU (United Kingdom); Lindsay, Kenneth W.; Sloss, Stuart; Teasdale, Evelyn M. [University Department of Neurosurgery and Department of Neuroradiology, Institute of Neurological Sciences, Southern General Hospital, Glasgow G52 4TF (United Kingdom); Patel, Dilip K.B. [Department of Radiology, Royal Infirmary of Edinburgh, Lauriston Place, Edinburgh EH4 2XU (United Kingdom)

    2003-02-01

    Can non-neuroradiologists detect intracranial aneurysms as well as neuroradiologists, using CT and MR angiography? Sixty patients undergoing intra-arterial digital subtraction angiography (IADSA) to detect aneurysms also underwent computed tomographic angiography (CTA) and time-of-flight magnetic resonance angiography (MRA). Consensus review of IADSA by two neuroradiologists was the reference standard. Two neuroradiologists, a neurosurgeon, a neuroradiographer and a general radiologist blinded to IADSA, plain CT and clinical data, independently reviewed hard-copy base and reconstructed maximum intensity projection images of the CTA and MRA studies. Thirty patients had a total of 63 aneurysms, 71.4% were {<=}5 mm in size. Compared with IADSA, mean accuracy per patient for neuroradiologists was CTA 0.87 (95% CI 0.75-0.94), and MRA 0.82 (0.70-0.90); for the other observers it was CTA 0.81 (0.75-0.86), and MRA 0.78 (0.71-0.84). Sensitivity per aneurysm for neuroradiologists was CTA 0.63 (0.50-0.75), and MRA 0.43 (0.6-0.74); for the other observers it was CTA 0.52 (0.44-0.59), and MRA 0.38 (0.31-0.45). Differences between readers and modalities were not statistically significant. Agreement with IADSA was ''good'' for neuroradiologists: kappa 0.73 for CTA, and 0.63 for MRA. For the other observers, agreement with IADSA was ''moderate'': kappa 0.59 for CTA, and 0.56 for MRA. Neuroradiologists performed consistently better than the other observers, although differences did not reach statistical significance. (orig.)

  10. Multislice Helical CT Angiography in Diagnostic of Intracranial and Extracranial Arterial Dissection

    International Nuclear Information System (INIS)

    Radzina, M.; Krumina, G.; Pupols, J.

    2007-01-01

    complete information about arterial extracranial and intracranial vascular system. CTA is highly informative in characterization of dissection site and morphology, also diagnostic of combined brain pathology. Appropriate quality CTA requires high capacity: at least 16 slice helical CT equipment that provides quick examination with wide range of post processing possibilities. Non enhanced brain CT is recommended before CTA, to specify cerebral structural changes and to identify vascular calcified plaques. Indications for intracranial CTA: subarachnoidal hemorrhage, intracerebral hematoma, intraventricular hemorrhage, cerebral infarction; outpatient praxis: stenoses, aneurysms, arteriovenous malformations, cerebral infarction history, vasculitis. Indications for brachiocephalic CTA are: acute head-neck trauma, ischemia; for outpatient praxis: US suspected vessel stenoses, cerebral infarction history. Selected protocol with post process ing opens up new opportunities for further research of most optimized CTA follow up time, evaluation of recanalization, and randomization of patients, angkalcinguldisekcija, for stenting procedures of dissected arterial segment. authors)

  11. Safety and efficiency of flow diverters for treating small intracranial aneurysms: A systematic review and meta-analysis.

    Science.gov (United States)

    Yao, Xiyang; Ma, Junwei; Li, Haiying; Shen, Haitao; Lu, Xiaojun; Chen, Gang

    2017-02-01

    Background We evaluated the safety and efficiency of flow diverters (FDs) in treating small intracranial aneurysms (IAs). Materials and Methods We reviewed the literature published in PubMed and EMBASE. R for Project software was used to calculate the complete aneurysm occlusion rates, procedure-related neurologic mortality, procedure-related neurologic morbidity and procedure-related permanent morbidity. Results Ten observational studies were included in this analysis. The complete aneurysm occlusion rate was 84.23% (80.34%-87.76%), the procedure-related neurologic mortality was 0.87% (0.29%-1.74%), the procedure-related neurologic morbidity rate was 5.22% (3.62%-7.1%), the intracerebral haemorrhage rate was 1.42% (0.64%-2.49%), the ischemic rate was 2.35% (1.31%-3.68%), the subarachnoid haemorrhage rate was 0.03% (0%-0.32%) and the procedure-related permanent morbidity was 2.41% (0.81%-4.83%). Conclusions Treatment of small IAs with FDs may be correlated with high complete occlusion rates and low complication rates. Future long-term follow-up randomized trials will determine the optimal treatment for small IAs.

  12. Is digital substraction angiography still needed for the follow-up of intracranial aneurysms treated by embolisation with detachable coils?

    International Nuclear Information System (INIS)

    Lubicz, Boris; Neugroschl, Carine; Collignon, Laurent; Francois, Olivier; Baleriaux, Danielle

    2008-01-01

    Follow-up of intracranial aneurysms treated by embolisation with detachable coils is mandatory to detect a possible recanalisation. The aim of this study was to compare contrast-enhanced magnetic resonance angiography (CE-MRA) with digital substraction angiography (DSA) used to detect aneurysm recanalisation to determine if DSA is still needed during follow-up. From May 2006 to May 2007, 55 patients with 67 aneurysms were treated by endosaccular coiling with (n=9) or without (n=58) an adjunctive stent. Follow-up imaging protocol included MRA at 6 and 12 months and a DSA at 12 months or earlier if a major recanalisation was identified on the 6-month MRA. Two neuroradiologists independently reviewed MRA images (readers 1 and 2) and two other reviewed DSA images. Follow-up DSA showed stability of the aneurysm occlusion in 52 cases, recanalisation in 14 cases, and further thrombosis in one. On CE-MRA, both readers identified all recanalisations but one (sensitivity of 93%) as they missed a major recanalisation in a 2-mm ruptured aneurysm. There were two false-positive evaluations by reader 1 and three for reader 2. Mean specificity of CE-MRA to detect aneurysm recanalisation was 95.5%. CE-MRA is accurate to detect aneurysm recanalisation after embolisation with detachable coils. CE-MRA may be proposed as first-intention imaging technique for their follow-up. However, its sensitivity and specificity remain inferior to that of DSA and major recurrences may be missed in very small aneurysms. Therefore, a single DSA remains mandatory during the imaging follow-up. (orig.)

  13. Glycemia in conditions of hypothermia in patients with intracranial aneurysmal hemorrhage

    Directory of Open Access Journals (Sweden)

    Світлана Олександрівна Дудукіна

    2015-04-01

    Full Text Available Despite the proven effectiveness of hypothermia as a method of neuroprotection, the presence of significant side effects requires further development of detailed protocols of usage, especially glucose.Aim: Improving treatment outcomes of patients with subarachnoid aneurysmal hemorrhage by preventing the development of hyperglycemia during systemic hypothermia.Materials and Methods: The study involved 48 patients with spontaneous subarachnoid hemorrhage of aneurysmal origin. All patients were conducted intracranial surgery - clipping aneurysms of cerebral vessels during regression of arterial vascular spasm (AVS in the systemic hypothermia prevention. Therapeutic hypothermia was performed in 29 patients with complicated disease course for 48 hours. It is evaluated the effectiveness of its own method of prevention and correction of hyperglycemia - permanent short-acting insulin before the warm saline at a dose of 2 units/hour during hypothermiaResults: During the prevention of hypothermia using methods of hyperglycemia episodes of above 10 mmol / L did not observe the rejection of a group of patients using the conventional method of correction of glycemia. Episodes of hypoglycemia do not observed in both groups of the study. Up to 48 hours of therapeutic hypothermia glucose levels remained stable, after 48 hours of hypothermia it is observed a significant increase in blood glucose that was cool termination criterion.Conclusions: Holding insulin infusion at short-acting dose of 2 units/hour during prophylactic hypothermia prevents episodes of hyperglycemia and consequently helps to maintain homeostasis. Carrying insulin infusion at short-acting dose of 2 units/hour during therapeutic hypothermia promotes stable blood glucose levels to 48 hours. After 48 hours of hypothermia in 51.72% of patients experienced a significant increase in blood glucose, which is one of the criteria for termination of cooling

  14. Endovascular therapeutic strategies in ruptured intracranial aneurysms

    International Nuclear Information System (INIS)

    Machi, Paolo; Lobotesis, Kyriakos; Vendrell, Jean Francoise; Riquelme, Carlos; Eker, Omer; Costalat, Vincent; Bonafe, Alain

    2013-01-01

    The aim of the present study was to evaluate endovascular techniques used currently which were not available at the time of ISAT inclusion period, such as balloon remodelling and flow-divertion, in order to assess whether these new technologies have improved the endovascular approach outcomes. We present a review of articles, published in major journals, with the aim to evaluate the efficacy and the safety of coiling with balloon remodelling for the treatment of ruptured aneurysms in comparison to coiling performed without such coadjutant techniques. Furthermore, we reviewed publications reporting on the treatment of ruptured aneurysms in the acute phase with the one of the most recent technologies available nowadays: the flow diverting stent. Looking at the recent literature the results regarding ruptured aneurysms treated with balloon assisted coiling (BAC) have shown an improvement in terms of anatomical results and morbi-mortality rates. Case series of ruptured middle cerebral artery (MCA) aneurysms treated by EVT report results similar to those obtained by surgical clipping. Several articles recently report encouraging results in treating ruptured dissecting and blister aneurysms with flow diverters. Questions regarding the best treatment available for ruptured aneurysms are yet to be answered. Hence there is a need for a subsequent trial aiming to answer these unresolved issues

  15. Aspirin as a Promising Agent for Decreasing Incidence of Cerebral Aneurysm Rupture

    NARCIS (Netherlands)

    Hasan, David M.; Mahaney, Kelly B.; Brown, Robert D.; Meissner, Irene; Piepgras, David G.; Huston, John; Capuano, Ana W.; Torner, James C.; Groen, R.J.M.

    2011-01-01

    Background and Purpose-Chronic inflammation is postulated as an important phenomenon in intracranial aneurysm wall pathophysiology. This study was conducted to determine if aspirin use impacts the occurrence of intracranial aneurysm rupture. Methods-Subjects enrolled in the International Study of

  16. Shape-memory polymer foam device for treating aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, Jason M.; Benett, William J.; Small, Ward; Wilson, Thomas S.; Maitland, Duncan J; Hartman, Jonathan

    2017-05-30

    A system for treating an aneurysm in a blood vessel or vein, wherein the aneurysm has a dome, an interior, and a neck. The system includes a shape memory polymer foam in the interior of the aneurysm between the dome and the neck. The shape memory polymer foam has pores that include a first multiplicity of pores having a first pore size and a second multiplicity of pores having a second pore size. The second pore size is larger than said first pore size. The first multiplicity of pores are located in the neck of the aneurysm. The second multiplicity of pores are located in the dome of the aneurysm.

  17. Genetic study of intracranial aneurysms.

    Science.gov (United States)

    Yan, Junxia; Hitomi, Toshiaki; Takenaka, Katsunobu; Kato, Masayasu; Kobayashi, Hatasu; Okuda, Hiroko; Harada, Kouji H; Koizumi, Akio

    2015-03-01

    Rupture of intracranial aneurysms (IAs) causes subarachnoid hemorrhage, leading to immediate death or severe disability. Identification of the genetic factors involved is critical for disease prevention and treatment. We aimed to identify the susceptibility genes for IAs. Exome sequencing was performed in 12 families with histories of multiple cases of IA (number of cases per family ≥3), with a total of 42 cases. Various filtering strategies were used to select the candidate variants. Replicate association studies of several candidate variants were performed in probands of 24 additional IA families and 426 sporadic IA cases. Functional analysis for the mutations was conducted. After sequencing and filtering, 78 variants were selected for the following reasons: allele frequencies of variants in 42 patients was significantly (PIA within ≥1 family; variants predicted damage to the structure or function of the protein by PolyPhen-2 (Polymorphism Phenotyping V2) and SIFT (Sorting Intolerance From Tolerant). We selected 10 variants from 9 genes (GPR63, ADAMST15, MLL2, IL10RA, PAFAH2, THBD, IL11RA, FILIP1L, and ZNF222) to form 78 candidate variants by considering commonness in families, known disease genes, or ontology association with angiogenesis. Replicate association studies revealed that only p.E133Q in ADAMTS15 was aggregated in the familial IA cases (odds ratio, 5.96; 95% confidence interval, 2.40-14.82; P=0.0001; significant after the Bonferroni correction [P=0.05/78=0.0006]). Silencing ADAMTS15 and overexpression of ADAMTS15 p.E133Q accelerated endothelial cell migration, suggesting that ADAMTS15 may have antiangiogenic activity. ADAMTS15 is a candidate gene for IAs. © 2015 American Heart Association, Inc.

  18. Impact of metal artifact reduction software on image quality of gemstone spectral imaging dual-energy cerebral CT angiography after intracranial aneurysm clipping

    Energy Technology Data Exchange (ETDEWEB)

    Dunet, Vincent; Bernasconi, Martine; Hajdu, Steven David; Meuli, Reto Antoine; Zerlauth, Jean-Baptiste [Lausanne University Hospital, Department of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Daniel, Roy Thomas [Lausanne University Hospital, Department of Neurosurgery, Lausanne (Switzerland)

    2017-09-15

    We aimed to assess the impact of metal artifact reduction software (MARs) on image quality of gemstone spectral imaging (GSI) dual-energy (DE) cerebral CT angiography (CTA) after intracranial aneurysm clipping. This retrospective study was approved by the institutional review board, which waived patient written consent. From January 2013 to September 2016, single source DE cerebral CTA were performed in 45 patients (mean age: 60 ± 9 years, male 9) after intracranial aneurysm clipping and reconstructed with and without MARs. Signal-to-noise (SNR), contrast-to-noise (CNR), and relative CNR (rCNR) ratios were calculated from attenuation values measured in the internal carotid artery (ICA) and middle cerebral artery (MCA). Volume of clip and artifacts and relative clip blurring reduction (rCBR) ratios were also measured at each energy level with/without MARs. Variables were compared between GSI and GSI-MARs using the paired Wilcoxon signed-rank test. MARs significantly reduced metal artifacts at all energy levels but 130 and 140 keV, regardless of clips' location and number. The optimal rCBR was obtained at 110 and 80 keV, respectively, on GSI and GSI-MARs images, with up to 96% rCNR increase on GSI-MARs images. The best compromise between metal artifact reduction and rCNR was obtained at 70-75 and 65-70 keV for GSI and GSI-MARs images, respectively, with up to 15% rCBR and rCNR increase on GSI-MARs images. MARs significantly reduces metal artifacts on DE cerebral CTA after intracranial aneurysm clipping regardless of clips' location and number. It may be used to reduce radiation dose while increasing CNR. (orig.)

  19. Prognosis of patients in coma after acute subdural hematoma due to ruptured intracranial aneurysm.

    Science.gov (United States)

    Torné, Ramon; Rodríguez-Hernández, Ana; Romero-Chala, Fabián; Arikan, Fuat; Vilalta, Jordi; Sahuquillo, Juan

    2016-04-01

    Acute subdural hematomas (aSDH) secondary to intracranial aneurysm rupture are rare. Most patients present with coma and their functional prognosis has been classically considered to be very poor. Previous studies mixed good-grade and poor-grade patients and reported variable outcomes. We reviewed our experience by focusing on patients in coma only and hypothesized that aSDH might worsen initial mortality but not long-term functional outcome. Between 2005 and 2013, 440 subarachnoid hemorrhage (SAH) patients were admitted to our center. Nineteen (4.3%) were found to have an associated aSDH and 13 (2.9%) of these presented with coma. Their prospectively collected clinical and outcome data were reviewed and compared with that of 104 SAH patients without aSDH who presented with coma during the same period. Median aSDH thickness was 10mm. Four patients presented with an associated aneurysmal cortical laceration and only one had good recovery. Overall, we observed good long-term outcomes in both SAH patients in coma with aSDH and those without aSDH (38.5% versus 26.4%). Associated aSDH does not appear to indicate a poorer long-term functional prognosis in SAH patients presenting with coma. Anisocoria and brain herniation are observed in patients with aSDH thicknesses that are smaller than those observed in trauma patients. Despite a high initial mortality, early surgery to remove the aSDH results in a good outcome in over 60% of survivors. Aneurysmal cortical laceration appears to be an independent entity which shows a poorer prognosis than other types of aneurysmal aSDH. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Hemodynamic transition driven by stent porosity in sidewall aneurysms.

    Science.gov (United States)

    Bouillot, Pierre; Brina, Olivier; Ouared, Rafik; Lovblad, Karl-Olof; Farhat, Mohamed; Pereira, Vitor Mendes

    2015-05-01

    The healing process of intracranial aneurysms (IAs) treated with flow diverter stents (FDSs) depends on the IA flow modifications and on the epithelization process over the neck. In sidewall IA models with straight parent artery, two main hemodynamic regimes with different flow patterns and IA flow magnitude were broadly observed for unstented and high porosity stented IA on one side, and low porosity stented IA on the other side. The hemodynamic transition between these two regimes is potentially involved in thrombosis formation. In the present study, CFD simulations and multi-time lag (MTL) particle imaging velocimetry (PIV) measurements were combined to investigate the physical nature of this transition. Measurable velocity fields and non-measurable shear stress and pressure fields were assessed experimentally and numerically in the aneurysm volume in the presence of stents with various porosities. The two main regimes observed in both PIV and CFD showed typical flow features of shear and pressure driven regimes. In particular, the waveform of the averaged IA velocities was matching both the shear stress waveform at IA neck or the pressure gradient waveform in parent artery. Moreover, the transition between the two regimes was controlled by stent porosity: a decrease of stent porosity leads to an increase (decrease) of pressure differential (shear stress) through IA neck. Finally, a good PIV-CFD agreement was found except in transitional regimes and low motion eddies due to small mismatch of PIV-CFD running conditions. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. 3D-CT angiography. Intracranial arterial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Asato, Mikio; Tong, X.Q.; Tamura, Shozo [Miyazaki Medical Coll., Kiyotake (Japan)] [and others

    1997-06-01

    Since its introduction, three dimensional CT angiography (3D-CTA) on spiral (helical) CT has played an important role in clinical imaging. Initially it was reported to be useful in depicting aortic abnormalities, afterwards the merit in detecting intracranial aneurysm by 3D-CTA was also described. We have investigated the usefullness of 3D-CTA in detecting patients of intracranial aneurysm as well as arterio-venous malformation (AVM), Moyamoya disease and stenosis of middle cerebral artery, meanwhile the MR angiography (MRA) and digital subtraction angiography (DSA) examination of these patients were also studied as comparison to the 3D-CTA results. The sensitivity and specificity on investigating intracranial aneurysm were similar with other reports so far. 3D-CTA was possible to identify the feeding artery, nidus and draining vein of AVM, although DSA showed higher detectability. Occlusion of internal carotid artery and post-operative anastomosis in Moyamoya disease were all demonstrated by 3D-CTA, however the Moyamoya collaterals were shown better on MRA. 3D-CTA revealed the site of stenosis of middle cerebral artery in all of our cases, but in general maximum intensity projection (MIP) images can provide more exact information about the degree of stenosis. Five years has passed since the emergence of spiral CT and utilizing of 3D-CTA in clinical applications. With the development of hard and soft ware in the near future, it is possible to delineate more small vessels by 3D-CTA. We predict that 3D-CTA would be widely used for detecting vasculature of the whole body, and may take the place of conventional angiography in many cases. (author)

  2. Construct canine intracranial aneurysm model by endovascular technique

    International Nuclear Information System (INIS)

    Liang Xiaodong; Liu Yizhi; Ni Caifang; Ding Yi

    2004-01-01

    Objective: To construct canine bifurcation aneurysms suitable for evaluating the exploration of endovascular devices for interventional therapy by endovascular technique. Methods: The right common carotid artery of six dogs was expanded with a pliable balloon by means of endovascular technique, then embolization with detached balloon was taken at their originations DAS examination were performed on 1, 2, 3 d after the procedurse. Results: 6 aneurysm models were created in six dogs successfully with the mean width and height of the aneurysms decreasing in 3 days. Conclusions: This canine aneurysm model presents the virtue in the size and shape of human cerebral bifurcation saccular aneurysms on DSA image, suitable for developing the exploration of endovascular devices for aneurismal therapy. The procedure is quick, reliable and reproducible. (authors)

  3. Preliminary clinical application in the cranial internal carotid artery of covered stents specially designed for intracranial vasculature

    International Nuclear Information System (INIS)

    Li Minghua; Luo Qiyi; Fang Chun; Xie Zhiyong; Cheng Yingsheng; Gao Bulang; Li Yu; Zhang Beilei; Xie Jian; Wang Yongli

    2007-01-01

    Objective: To investigate the flexibility of both the covered stents specially designed for use in intracranial vasculature and the delivering system in passing through the bone tube and the physiological curves of the cranial internal carotid artery (CICA) to reach the targeted area, the performance (adherence) of the covered stents in occluding vascular wall diseases and the impact on the vascular branches of the covered segment. Methods: The covered stents specially designed for use in intracranial vasculature were used to treat 13 patients with CICA diseases using endovascular techniques. There were 4 huge pseudoaneurysms, 4 giant aneurysms, 3 small wide-necked aneurysms, 1 giant pseudoaneurysm with concurrent internal carotid cavernous fistula (CCF), and 1 CCF. Prior to the detachment of the covered stents, balloon occlusion test (BOT) of the internal carotid artery on the diseased side and whole-brain digital subtraction angiography (DSA) were performed in all the patients. Three to 16 months following procedure, DSA and clinical follow-ups were performed. Results: Thirteen patients all tolerated the BOT well with the DSA demonstrating well-opened anterior and posterior communicating arteries. The covered stents and the delivering systems all successfully passed CICA to reach the targeted diseased area, with the diseased segments of the internal carotid artery including C3-C4 in 4 cases, C4-C5 in 4 and C6-C7 in 5. Immediately following the detachment of the covered stents, DSA demonstrated that 7 aneurysms were completely occluded, 4 aneurysms had slight endoleak, and 1 CCF had markedly-decreased blood flow through the fistula. In the patient with concurrent pseudoaneurysm and CCF, the pseudoaneurysm disappeared and the blood flow through the fistula was markedly-reduced immediately following the stenting procedure. Apart from one patient with aneurysmal subarachnoid hemorrhage who died due to extensive vascular spasm on the 9th day following the stenting

  4. Comparison of remnant size in embolized intracranial aneurysms measured at follow-up with DSA and MRA

    Energy Technology Data Exchange (ETDEWEB)

    Serafin, Zbigniew; Strzesniewski, Piotr; Lasek, Wladyslaw [Nicolaus Copernicus University, Department of Radiology and Diagnostic Imaging, Collegium Medicum, Bydgoszcz (Poland); Beuth, Wojciech [University of Humanities and Economics in Wloclawek, Faculty of Health Sciences, Wloclawek (Poland)

    2012-12-15

    The possibility of recanalization and the need for retreatment are the most important limitations of intracranial aneurysm embolization. The purpose of the study was to compare the size of aneurysm remnants measured at follow-up with three-dimensional digital subtracted angiography (3D-DSA) and magnetic resonance angiography (MRA). Twenty-six aneurysms were found incompletely occluded in 72 consecutively examined patients at a follow-up after 3 months. The diameters and volume of aneurysm remnants were compared between 3D-DSA, time-of-flight MRA (TOF-MRA), contrast-enhanced TOF-MRA (CE-TOF-MRA), and contrast-enhanced MRA (CE-MRA) at 1.5 T. There was a significant correlation between remnant volumes calculated based on 3D-DSA and all MRA modalities. The intraobserver variability of the measurements ranged from 3.4 to 4.1 % and the interobserver variability from 5.8 to 7.3 %. There were no significant differences in the variability between the techniques. The mean residual filling volume ranged from 16.3 {+-} 19.0 mm{sup 3} in TOF-MRA to 30.5 {+-} 44.6 mm{sup 3} in 3D-DSA (P < 0.04). Significant differences were found in the volumes measured with 3D-DSA and CE-MRA as compared to TOF-MRA and CE-TOF-MRA (P < 0.01). There was a moderate significant correlation between the residual filling and the relative error of measurement in the case of TOF-MRA and CE-TOF-MRA. TOF-MRA seems to underestimate the size of aneurysm remnants detected at follow-up and should not be used as a sole imaging method to decide on re-embolization. (orig.)

  5. Comparison of remnant size in embolized intracranial aneurysms measured at follow-up with DSA and MRA

    International Nuclear Information System (INIS)

    Serafin, Zbigniew; Strzesniewski, Piotr; Lasek, Wladyslaw; Beuth, Wojciech

    2012-01-01

    The possibility of recanalization and the need for retreatment are the most important limitations of intracranial aneurysm embolization. The purpose of the study was to compare the size of aneurysm remnants measured at follow-up with three-dimensional digital subtracted angiography (3D-DSA) and magnetic resonance angiography (MRA). Twenty-six aneurysms were found incompletely occluded in 72 consecutively examined patients at a follow-up after 3 months. The diameters and volume of aneurysm remnants were compared between 3D-DSA, time-of-flight MRA (TOF-MRA), contrast-enhanced TOF-MRA (CE-TOF-MRA), and contrast-enhanced MRA (CE-MRA) at 1.5 T. There was a significant correlation between remnant volumes calculated based on 3D-DSA and all MRA modalities. The intraobserver variability of the measurements ranged from 3.4 to 4.1 % and the interobserver variability from 5.8 to 7.3 %. There were no significant differences in the variability between the techniques. The mean residual filling volume ranged from 16.3 ± 19.0 mm 3 in TOF-MRA to 30.5 ± 44.6 mm 3 in 3D-DSA (P < 0.04). Significant differences were found in the volumes measured with 3D-DSA and CE-MRA as compared to TOF-MRA and CE-TOF-MRA (P < 0.01). There was a moderate significant correlation between the residual filling and the relative error of measurement in the case of TOF-MRA and CE-TOF-MRA. TOF-MRA seems to underestimate the size of aneurysm remnants detected at follow-up and should not be used as a sole imaging method to decide on re-embolization. (orig.)

  6. Outcome after endovascular therapy of ruptured intracranial aneurysms: morbidity and impact of rebleeding

    International Nuclear Information System (INIS)

    Kremer, C.; Groden, C.; Zeumer, H.; Lammers, G.; Weineck, G.; Hansen, H.C.

    2002-01-01

    We evaluated midterm functional outcome after endovascular occlusion of aneurysms in patients with subarachnoid haemorrhage (SAH) and determined the incidence of late rebleeding as an additional prognostic parameter. We treated 79 consecutive patients with SAH from an intracranial aneurysm admitted from a neurological intensive care unit by the endovascular route between 1993 and 1997 and 52 survivors were followed up in 1999-2000. The mean interval between SAH and follow-up was 41 months (range 13-74 months). Outcome was determined by the Glasgow outcome (GOS) and Rankin (RS) scales and by questions concerning neuropsychological disorders. The patients were analysed according to Hunt and Hess (H and H) grades I-III or IV-V on admission. We observed two episodes of rebleeding (3%) with impact on outcome at 907 and 2010 days after SAH, respectively. A complete recovery (GOS 5) was achieved in 53% of H and H grade I-III and 17% of grade IV-V patients; with death rates 19% and 50%, and morbidity according to the RS (5-2) 18% and 29%, respectively. Midterm morbidity after endovascular therapy is thus low. Rebleeding with an impact on outcome can be observed up to 2010 days after SAH, suggesting that long-term angiographic follow-up is indispensable. (orig.)

  7. Thinner regions of intracranial aneurysm wall correlate with regions of higher wall shear stress: a 7.0 tesla MRI

    Science.gov (United States)

    Blankena, Roos; Kleinloog, Rachel; Verweij, Bon H.; van Ooij, Pim; ten Haken, Bennie; Luijten, Peter R.; Rinkel, Gabriel J.E.; Zwanenburg, Jaco J.M.

    2016-01-01

    Purpose To develop a method for semi-quantitative wall thickness assessment on in vivo 7.0 tesla (7T) MRI images of intracranial aneurysms for studying the relation between apparent aneurysm wall thickness and wall shear stress. Materials and Methods Wall thickness was analyzed in 11 unruptured aneurysms in 9 patients, who underwent 7T MRI with a TSE based vessel wall sequence (0.8 mm isotropic resolution). A custom analysis program determined the in vivo aneurysm wall intensities, which were normalized to signal of nearby brain tissue and were used as measure for apparent wall thickness (AWT). Spatial wall thickness variation was determined as the interquartile range in AWT (the middle 50% of the AWT range). Wall shear stress was determined using phase contrast MRI (0.5 mm isotropic resolution). We performed visual and statistical comparisons (Pearson’s correlation) to study the relation between wall thickness and wall shear stress. Results 3D colored AWT maps of the aneurysms showed spatial AWT variation, which ranged from 0.07 to 0.53, with a mean variation of 0.22 (a variation of 1.0 roughly means a wall thickness variation of one voxel (0.8mm)). In all aneurysms, AWT was inversely related to WSS (mean correlation coefficient −0.35, P<0.05). Conclusions A method was developed to measure the wall thickness semi-quantitatively, using 7T MRI. An inverse correlation between wall shear stress and AWT was determined. In future studies, this non-invasive method can be used to assess spatial wall thickness variation in relation to pathophysiologic processes such as aneurysm growth and –rupture. PMID:26892986

  8. Treatment of complex internal carotid artery aneurysms using radial artery grafts. Surgical technique, perioperative complications, and results in 17 patients

    International Nuclear Information System (INIS)

    Murai, Yasuo; Teramoto, Akira; Mizunari, Takayuki; Kobayashi, Shiro; Kamiyama, Hiroyasu

    2007-01-01

    Complex giant or large internal carotid artery aneurysms present a surgical challenge because limitations and difficulty are encountered with either clipping or endovascular treatment. Our review of previous reports suggests that no current vascular assessment can accurately predict the occurrence of ischemic complications after internal carotid artery ligation. The present study concerns surgical technique, complications, and clinical outcome of radial artery grafting followed by parent artery trapping or proximal occlusion for management of these difficult lesions. Between September 1997 and October 2005, we performed radial artery grafting followed immediately by parent artery occlusion in 17 patients with giant or large complex intracranial carotid aneurysms (3 men, 14 women; mean follow-up duration, 62 months). All patients underwent postoperative digital subtraction angiography to assess graft patency and aneurysm obliteration. All 17 aneurysms were excluded from the cerebral circulation, with all radial artery grafts patent. Among 4 patients with cranial nerve disturbances, dysfunction was temporary in 5; in the others, oculomotor nerve paresis persisted. No perioperative cerebral infarction occurred. Sensory aphasia reflecting cerebral contusions caused by temporal lobe retraction resolved within 2 months, as did hemiparesis from a postoperative epidural hematoma. With appropriate attention to surgical technique, radial artery grafting followed by acute parent artery occlusion is a safe treatment for complex internal carotid artery aneurysms. Graft patency and aneurysm thrombosis were achieved in all patients. Cranial nerve dysfunction (III, VI) caused by altered blood flow from the internal carotid artery after occlusion was the most common complication and typically was temporary. In our experience with these difficult aneurysms, not only clipping but also reconstruction of the internal carotid artery was required, especially for wide-necked symptomatic

  9. Dipeptidyl Peptidase-4 Inhibitor Anagliptin Prevents Intracranial Aneurysm Growth by Suppressing Macrophage Infiltration and Activation.

    Science.gov (United States)

    Ikedo, Taichi; Minami, Manabu; Kataoka, Hiroharu; Hayashi, Kosuke; Nagata, Manabu; Fujikawa, Risako; Higuchi, Sei; Yasui, Mika; Aoki, Tomohiro; Fukuda, Miyuki; Yokode, Masayuki; Miyamoto, Susumu

    2017-06-19

    Chronic inflammation plays a key role in the pathogenesis of intracranial aneurysms (IAs). DPP-4 (dipeptidyl peptidase-4) inhibitors have anti-inflammatory effects, including suppressing macrophage infiltration, in various inflammatory models. We examined whether a DPP-4 inhibitor, anagliptin, could suppress the growth of IAs in a rodent aneurysm model. IAs were surgically induced in 7-week-old male Sprague Dawley rats, followed by oral administration of 300 mg/kg anagliptin. We measured the morphologic parameters of aneurysms over time and their local inflammatory responses. To investigate the molecular mechanisms, we used lipopolysaccharide-treated RAW264.7 macrophages. In the anagliptin-treated group, aneurysms were significantly smaller 2 to 4 weeks after IA induction. Anagliptin inhibited the accumulation of macrophages in IAs, reduced the expression of MCP-1 (monocyte chemotactic protein 1), and suppressed the phosphorylation of p65. In lipopolysaccharide-stimulated RAW264.7 cells, anagliptin treatment significantly reduced the production of tumor necrosis factor α, MCP-1, and IL-6 (interleukin 6) independent of GLP-1 (glucagon-like peptide 1), the key mediator in the antidiabetic effects of DPP-4 inhibitors. Notably, anagliptin activated ERK5 (extracellular signal-regulated kinase 5), which mediates the anti-inflammatory effects of statins, in RAW264.7 macrophages. Preadministration with an ERK5 inhibitor blocked the inhibitory effect of anagliptin on MCP-1 and IL-6 expression. Accordingly, the ERK5 inhibitor also counteracted the suppression of p65 phosphorylation in vitro. A DPP-4 inhibitor, anagliptin, prevents the growth of IAs via its anti-inflammatory effects on macrophages. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  10. Experimental and CFD flow studies in an intracranial aneurysm model with Newtonian and non-Newtonian fluids.

    Science.gov (United States)

    Frolov, S V; Sindeev, S V; Liepsch, D; Balasso, A

    2016-05-18

    According to the clinical data, flow conditions play a major role in the genesis of intracranial aneurysms. The disorder of the flow structure is the cause of damage of the inner layer of the vessel wall, which leads to the development of cerebral aneurysms. Knowledge of the alteration of the flow field in the aneurysm region is important for treatment. The aim is to study quantitatively the flow structure in an patient-specific aneurysm model of the internal carotid artery using both experimental and computational fluid dynamics (CFD) methods with Newtonian and non-Newtonian fluids. A patient-specific geometry of aneurysm of the internal carotid artery was used. Patient data was segmented and smoothed to obtain geometrical model. An elastic true-to-scale silicone model was created with stereolithography. For initial investigation of the blood flow, the flow was visualized by adding particles into the silicone model. The precise flow velocity measurements were done using 1D Laser Doppler Anemometer with a spatial resolution of 50 μ m and a temporal resolution of 1 ms. The local velocity measurements were done at a distance of 4 mm to each other. A fluid with non-Newtonian properties was used in the experiment. The CFD simulations for unsteady-state problem were done using constructed hexahedral mesh for Newtonian and non-Newtonian fluids. Using 1D laser Doppler Anemometer the minimum velocity magnitude at the end of systole -0.01 m/s was obtained in the aneurysm dome while the maximum velocity 1 m/s was at the center of the outlet segment. On central cross section of the aneurysm the maximum velocity value is only 20% of the average inlet velocity. The average velocity on the cross-section is only 11% of the inlet axial velocity. Using the CFD simulation the wall shear stresses for Newtonian and non-Newtonian fluid at the end of systolic phase (t= 0.25 s) were computed. The wall shear stress varies from 3.52 mPa (minimum value) to 10.21 Pa (maximum value) for the

  11. Comparison of remnant size in embolized intracranial aneurysms measured at follow-up with DSA and MRA.

    Science.gov (United States)

    Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2012-12-01

    The possibility of recanalization and the need for retreatment are the most important limitations of intracranial aneurysm embolization. The purpose of the study was to compare the size of aneurysm remnants measured at follow-up with three-dimensional digital subtracted angiography (3D-DSA) and magnetic resonance angiography (MRA). Twenty-six aneurysms were found incompletely occluded in 72 consecutively examined patients at a follow-up after 3 months. The diameters and volume of aneurysm remnants were compared between 3D-DSA, time-of-flight MRA (TOF-MRA), contrast-enhanced TOF-MRA (CE-TOF-MRA), and contrast-enhanced MRA (CE-MRA) at 1.5 T. There was a significant correlation between remnant volumes calculated based on 3D-DSA and all MRA modalities. The intraobserver variability of the measurements ranged from 3.4 to 4.1 % and the interobserver variability from 5.8 to 7.3 %. There were no significant differences in the variability between the techniques. The mean residual filling volume ranged from 16.3 ± 19.0 mm(3) in TOF-MRA to 30.5 ± 44.6 mm(3) in 3D-DSA (P < 0.04). Significant differences were found in the volumes measured with 3D-DSA and CE-MRA as compared to TOF-MRA and CE-TOF-MRA (P < 0.01). There was a moderate significant correlation between the residual filling and the relative error of measurement in the case of TOF-MRA and CE-TOF-MRA. TOF-MRA seems to underestimate the size of aneurysm remnants detected at follow-up and should not be used as a sole imaging method to decide on re-embolization.

  12. Radiological analysis of subarachnoid hemorrhage from ruptured intracranial aneurysms

    International Nuclear Information System (INIS)

    Lee, Jong Doo; Suh, Jung Ho; Kim, Dong Ik

    1988-01-01

    The CT findings of 98 patients with subarachnoid hemorrhage due to aneurysmal rupture were analyzed and compared with cerebral angiography for the purpose of preangiographic prediction of aneurysmal location as well as evaluation of the CT features corresponding to the vasospasm or ischemic neurologic dysfunctions. The results were as follows: 1.Aneurysms could be identified on initial cerebral angiography in 82 out of 98 patients with subarachnoid hemorrhage and anterior communicating artery aneurysms were most common (42 cases), followed by MCA, posterior communicating artery, ICA, basilar artery in order of frequency. 2.The CT findings of those patients were hemorrhage in subarachnoid space (69%), localized hematoma (47%), ventricular dilatation (31%), enhancing nodule (23%), cisternal enhancement (20%), cerebral infarction (15%), ventricular hemorrhage (14%), and epidural hemorrhage (3%). 3.Localized hematoma was more prevalent in anterior communicating artery aneurysm rupture (54%), and less frequently in MCA, posterior communicating artery and ICA aneurysms. 4.Most of aneurysmal sac could be identified as enhancing nodule on CT when the real size were over 1 cm. 5.The size of ruptured aneurysm could be predicted in many patients with ACA and MCA aneurysm according to the CT features such as hemorrhagic patterns, location of hematomas or enhancing nodules. 6.Localized hematoma or blood clots and cerebral infarction are considered to be the CT features corresponding to the angiographic vasospasm

  13. Successful Aortic Banding for Type IA Endoleak Due to Neck Dilatation after Endovascular Abdominal Aortic Aneurysm Repair: Case Report.

    Science.gov (United States)

    Tashima, Yasushi; Tamai, Koichi; Shirasugi, Takehiro; Sato, Kenichiro; Yamamoto, Takahiro; Imamura, Yusuke; Yamaguchi, Atsushi; Adachi, Hideo; Kobinata, Toshiyuki

    2017-09-25

    A 69-year-old man with a type IA endoleak that developed approximately 21 months after endovascular abdominal aortic aneurysm repair (EVAR) of a 46 mm diameter aneurysm was referred to our department. He had impaired renal function, Parkinson's disease, and previous cerebral infarction. Computed tomography angiography showed a type IA endoleak with neck dilatation and that the aneurysm had grown to 60 mm in diameter. We decided to perform aortic banding. The type IA endoleak disappeared after banding and the patient was discharged on postoperative day 10. Aortic banding may be effective for type IA endoleak after EVAR and less invasive for high-risk patients in particular.

  14. Surgical outcomes of Majewski osteodysplastic primordial dwarfism Type II with intracranial vascular anomalies.

    Science.gov (United States)

    Teo, Mario; Johnson, Jeremiah N; Bell-Stephens, Teresa E; Marks, Michael P; Do, Huy M; Dodd, Robert L; Bober, Michael B; Steinberg, Gary K

    2016-12-01

    OBJECTIVE Majewski osteodysplastic primordial dwarfism Type II (MOPD II) is a rare genetic disorder. Features of it include extremely small stature, severe microcephaly, and normal or near-normal intelligence. Previous studies have found that more than 50% of patients with MOPD II have intracranial vascular anomalies, but few successful surgical revascularization or aneurysm-clipping cases have been reported because of the diminutive arteries and narrow surgical corridors in these patients. Here, the authors report on a large series of patients with MOPD II who underwent surgery for an intracranial vascular anomaly. METHODS In conjunction with an approved prospective registry of patients with MOPD II, a prospectively collected institutional surgical database of children with MOPD II and intracranial vascular anomalies who underwent surgery was analyzed retrospectively to establish long-term outcomes. RESULTS Ten patients with MOPD II underwent surgery between 2005 and 2012; 5 patients had moyamoya disease (MMD), 2 had intracranial aneurysms, and 3 had both MMD and aneurysms. Patients presented with transient ischemic attack (TIA) (n = 2), ischemic stroke (n = 2), intraparenchymal hemorrhage from MMD (n = 1), and aneurysmal subarachnoid hemorrhage (n = 1), and 4 were diagnosed on screening. The mean age of the 8 patients with MMD, all of whom underwent extracranial-intracranial revascularization (14 indirect, 1 direct) was 9 years (range 1-17 years). The mean age of the 5 patients with aneurysms was 15.5 years (range 9-18 years). Two patients experienced postoperative complications (1 transient weakness after clipping, 1 femoral thrombosis that required surgical repair). During a mean follow-up of 5.9 years (range 3-10 years), 3 patients died (1 of subarachnoid hemorrhage, 1 of myocardial infarct, and 1 of respiratory failure), and 1 patient had continued TIAs. All of the surviving patients recovered to their neurological baseline. CONCLUSIONS Patients with MMD

  15. Circulating neutrophil transcriptome may reveal intracranial aneurysm signature

    Science.gov (United States)

    Tutino, Vincent M.; Poppenberg, Kerry E.; Jiang, Kaiyu; Jarvis, James N.; Sun, Yijun; Sonig, Ashish; Siddiqui, Adnan H.; Snyder, Kenneth V.; Levy, Elad I.; Kolega, John

    2018-01-01

    Background Unruptured intracranial aneurysms (IAs) are typically asymptomatic and undetected except for incidental discovery on imaging. Blood-based diagnostic biomarkers could lead to improvements in IA management. This exploratory study examined circulating neutrophils to determine whether they carry RNA expression signatures of IAs. Methods Blood samples were collected from patients receiving cerebral angiography. Eleven samples were collected from patients with IAs and 11 from patients without IAs as controls. Samples from the two groups were paired based on demographics and comorbidities. RNA was extracted from isolated neutrophils and subjected to next-generation RNA sequencing to obtain differential expressions for identification of an IA-associated signature. Bioinformatics analyses, including gene set enrichment analysis and Ingenuity Pathway Analysis, were used to investigate the biological function of all differentially expressed transcripts. Results Transcriptome profiling identified 258 differentially expressed transcripts in patients with and without IAs. Expression differences were consistent with peripheral neutrophil activation. An IA-associated RNA expression signature was identified in 82 transcripts (pIAs on hierarchical clustering. Furthermore, in an independent, unpaired, replication cohort of patients with IAs (n = 5) and controls (n = 5), the 82 transcripts separated 9 of 10 patients into their respective groups. Conclusion Preliminary findings show that RNA expression from circulating neutrophils carries an IA-associated signature. These findings highlight a potential to use predictive biomarkers from peripheral blood samples to identify patients with IAs. PMID:29342213

  16. Differential expression levels of collagen 1A2, tissue inhibitor of metalloproteinase 4, and cathepsin B in intracranial aneurysms.

    Science.gov (United States)

    Babu, R Arun; Paul, Pradip; Purushottam, Meera; Srinivas, Dwarakanath; Somanna, Sampath; Jain, Sanjeev

    2016-01-01

    Intracranial aneurysms (IAs) express a variety of differentially expressed genes when compared to the normal artery. The aim of this study was to evaluate the expression level of a few genes in the aneurysm wall and to correlate them with various clinicoradiological factors. The mRNA level of collagen 1A2 (COL1A2), tissue inhibitor of metalloproteinase 4 (TIMP4), and cathepsin B (CTSB) genes were studied in 23 aneurysmal walls and 19 superficial temporal arteries harvested from 23 patients undergoing clipping of IAs, by real-time polymerase chain reaction method. The mean fold change of COL1A2 gene between the aneurysm sample and the superficial temporal artery (STA) sample was 2.46 ± 0.12, that of TIMP4 gene was 0.31 ± 0, and that of CTSB gene was 31.47 ± 39.01. There was a positive correlation of TIMP4 expression level with maximum diameter of aneurysm (P = 0.008) and fundus of aneurysm (P = 0.012). The mean fold change of CTSB of patients who had preoperative hydrocephalus in the computed tomogram (CT) scan of the head at admission was 56.16 and that of the patients who did not have hydrocephalus was 13.51 (P = 0.008). The mean fold change of CTSB of patients who developed fresh postoperative deficits or worsening of the preexisting deficits was 23.64 and that of the patients who did not develop was 42.22 (P = 0.039). COL1A2 gene and CTSB genes were overexpressed, and TIMP4 gene was underexpressed in the aneurysmal sac compared to STA and their expression levels were associated with a few clinicoradiological factors.

  17. Feasibility of Using Intravascular Ultrasonography for Assessment of Giant Cavernous Aneurysm after Endovascular Treatment: A Technical Report

    Science.gov (United States)

    Majidi, Shahram; Grigoryan, Mikayel; Tekle, Wondwossen G; Watanabe, Masaki; Qureshi, Adnan I

    2012-01-01

    Introduction Intravascular ultrasonography (IVUS) has been shown as a valuable adjunct imaging tool during endovascular procedures but its value in detection of any recurrence during follow up after endovascular coil embolization of large and giant intracranial aneurysms is not reported. Methods A 41 years old man who had been treated using stent assisted coil embolization for cavernous segment aneurysm of the left internal carotid artery underwent 60 month angiographic follow up. Concurrently, IVUS catheter was advanced under fluoroscopic guidance inside the cavernous portion of the left internal carotid artery. Then IVUS images were used to visualize the stent, coil loops, and aneurysm neck. Results The angiographic images were limited because of superimposition of the aneurysm on the parent vessel in all projections. IVUS images demonstrated that the stent was patent along its whole length and there was no sign of stent deformity or in-stent thrombosis. Loops of the coil were visualized as hyperechoic signals inside the aneurysm and there was no sign of herniated loops of coil inside the stent. Conclusion In this case report, we observed that adjunct use of IVUS can provide valuable information not ascertained by angiography during follow up assessment of coil embolized aneurysm. PMID:22737259

  18. Deep neural network-based computer-assisted detection of cerebral aneurysms in MR angiography.

    Science.gov (United States)

    Nakao, Takahiro; Hanaoka, Shouhei; Nomura, Yukihiro; Sato, Issei; Nemoto, Mitsutaka; Miki, Soichiro; Maeda, Eriko; Yoshikawa, Takeharu; Hayashi, Naoto; Abe, Osamu

    2018-04-01

    The usefulness of computer-assisted detection (CAD) for detecting cerebral aneurysms has been reported; therefore, the improved performance of CAD will help to detect cerebral aneurysms. To develop a CAD system for intracranial aneurysms on unenhanced magnetic resonance angiography (MRA) images based on a deep convolutional neural network (CNN) and a maximum intensity projection (MIP) algorithm, and to demonstrate the usefulness of the system by training and evaluating it using a large dataset. Retrospective study. There were 450 cases with intracranial aneurysms. The diagnoses of brain aneurysms were made on the basis of MRA, which was performed as part of a brain screening program. Noncontrast-enhanced 3D time-of-flight (TOF) MRA on 3T MR scanners. In our CAD, we used a CNN classifier that predicts whether each voxel is inside or outside aneurysms by inputting MIP images generated from a volume of interest (VOI) around the voxel. The CNN was trained in advance using manually inputted labels. We evaluated our method using 450 cases with intracranial aneurysms, 300 of which were used for training, 50 for parameter tuning, and 100 for the final evaluation. Free-response receiver operating characteristic (FROC) analysis. Our CAD system detected 94.2% (98/104) of aneurysms with 2.9 false positives per case (FPs/case). At a sensitivity of 70%, the number of FPs/case was 0.26. We showed that the combination of a CNN and an MIP algorithm is useful for the detection of intracranial aneurysms. 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:948-953. © 2017 International Society for Magnetic Resonance in Medicine.

  19. Epidemiological study of 183 patients with spontaneous rupture of cerebral aneurysm

    International Nuclear Information System (INIS)

    Antonova, D.; Tasheva, E.

    2015-01-01

    Cerebral vessels aneurysms represent a significant part of the cerebral vessels pathology. There is no extensive study on that in Bulgaria. We present a study of 183 patients with spontaneous rupture of cerebral aneurysm, diagnosed and treated in UMHATEM ‘Pirogov’, Sofia. We used clinical methods - data from subject history, analysis of the accompanying documentation, subject medical chart; imaging-diagnostics methods - CT, DSA and MRI; and statistical methods. A total of 183 patients with ruptured intracranial aneurysms were studied. 65% were females and 35% were men.The ration female/male is 1.86, The mean age of all patients is 53.1 ±10.1 years. The highest incidence of ruptured aneurysms is seen in the age group 50 to 59 years. Aneurysms of a. cerebri media and a. communicants anterior are the most frequent (63.4% in total); while the lest are those of a basilaris (4.9%). 88.5% of the aneurysms in the studied group are small, 9.8% are large and 1.6% are giant. Intracranial hematomas are seen in 13.1% of the patients with ruptured aneurysms. Most frequently hematomas are connected with a. cerebri media and a.communicants anterior (87.5% in total). Patients with multiple aneurysms are 11.5% in total, 85.7% of them with an aneurysm of a.cerebri media. The incidence of ruptured cerebral aneurysms is higher amongst female. Frequency in the fifth decade of life is the highest. Most often seen are the aneurysms of a. cerebri media and a. communicants anterior, and the least - those of a. basilaris. Intracranial hematomas most frequently are associated with ruptures of a. cerebri media and a. communicants anterior, in patients with multiple aneurysms the highest is the frequency of aneurysms of a. cerebri media. (authors)

  20. Appearance and impact of post-operative intracranial clips and coils on whole-brain CT angiography and perfusion

    International Nuclear Information System (INIS)

    Roach, Cayce J.; Russell, Cheryl L.; Hanson, Eric H.; Bluett, Brent; Orrison, William W.

    2012-01-01

    Background: To evaluate the effect of vascular clips and endovascular coils placed for intracranial aneurysms and arteriovenous malformations on whole-brain computed tomography (CT) angiography and perfusion. Methods: A 320-detector row dynamic volume CT system imaged 11 patients following surgical placement of vascular clips or endovascular coils. The extent of clip and coil subtraction by automated software was evaluated using CT digital subtraction angiography and CT perfusion. Impact on CT perfusion values by retained intracranial devices was compared to age- and gender-matched controls. Results: Clip and coil subtraction on CT angiography was graded as good in 8 and moderate in 3 cases. A residual neck and additional aneurysm were noted in 1 of 11 patients. Post-procedural axial slice level CT perfusion values decreased in reliability with increasing proximity to the metallic devices secondary to beam hardening. However, the intracranial devices did not affect axial slice level CTP values of cerebral blood volume, cerebral blood flow and mean transit time outside of the level of the device. Time to peak values was globally decreased outside of the immediate vascular intervention region. Conclusions: Advances in CT technology have provided clinically useful subtraction of intracranial clips and coils. While CT perfusion values were altered in device subtraction areas and within beam hardening artifact areas; they can provide valuable postoperative information on whole-brain hemodynamics. In selected cases, the combination of CT angiography and whole-brain CT perfusion can offer an alternative to conventional angiography that is a more invasive option.

  1. Paediatric dissecting posterior cerebral aneurysms: report of two cases and review of the literature

    International Nuclear Information System (INIS)

    Vilela, Pedro; Goulao, Augusto

    2006-01-01

    Intracranial aneurysms in the paediatric population are uncommon, accounting for 2% to 6% of all aneurysms, and spontaneous arterial dissection is rarely reported as the cause of aneurysms in children, especially in the posterior cerebral artery. Two cases of paediatric spontaneous posterior cerebral artery dissecting aneurysms are reported, one in a 33-month-old male child presenting with aneurysmal rupture and subarachnoid haemorrhage and the other in a 9-year-old boy with an unruptured aneurysm. The first child was successfully treated by endovascular parent vessel occlusion without neurological deficit and in the second a spontaneous thrombosis of the aneurysm and its parent artery occurred associated with hydrocephalus and a favourable outcome. Dissecting aneurysms are dynamic lesions with variable and unpredictable evolution and close follow-up and/or early treatment is warranted. Spontaneous arterial dissection is a rare, probably still under-recognized, cause of intracranial aneurysms that may be responsible for a significant number of aneurysms and spontaneous aneurysmal thromboses in children. (orig.)

  2. Paediatric dissecting posterior cerebral aneurysms: report of two cases and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Vilela, Pedro; Goulao, Augusto [Garcia de Orta Hospital, Neuroradiology Department, Almada (Portugal)

    2006-08-15

    Intracranial aneurysms in the paediatric population are uncommon, accounting for 2% to 6% of all aneurysms, and spontaneous arterial dissection is rarely reported as the cause of aneurysms in children, especially in the posterior cerebral artery. Two cases of paediatric spontaneous posterior cerebral artery dissecting aneurysms are reported, one in a 33-month-old male child presenting with aneurysmal rupture and subarachnoid haemorrhage and the other in a 9-year-old boy with an unruptured aneurysm. The first child was successfully treated by endovascular parent vessel occlusion without neurological deficit and in the second a spontaneous thrombosis of the aneurysm and its parent artery occurred associated with hydrocephalus and a favourable outcome. Dissecting aneurysms are dynamic lesions with variable and unpredictable evolution and close follow-up and/or early treatment is warranted. Spontaneous arterial dissection is a rare, probably still under-recognized, cause of intracranial aneurysms that may be responsible for a significant number of aneurysms and spontaneous aneurysmal thromboses in children. (orig.)

  3. Value of 3-D-MT-TONE-time of-flight magnetic resonance angiography in the detection of intracranial aneurysms in comparison to digital subtraction angiography. A prospective study

    International Nuclear Information System (INIS)

    Falk, A.; Schmieder, K.; Hentsch, A.; Harders, A.; Heuser, L.

    1996-01-01

    From March 1994 to March 1995 30 patients with 38 aneurysms were prospectively subjected to MRA as well as to DSA. Respiratory insufficient patients were excluded from MRA. The aneurysm size ranged from 3-50 mm with an average size of 9 mm. Correct diagnosis was done in 33 aneurysms (86.8%) in 26 of the patients. In 4 patients (13.3%) with 5 aneurysms, the blinded readers made an incorrect diagnosis due to degradation of image quality. One (2.6%) aneurysm was falsely described via MRA as well as via DSA. The sensitivity was 86.8%. In the control group of 30 patients three aneurysms were found, therefore the specificity was 90% and we could calculate a positive predictive value of 97.1%, a negative predictive value of 84.4% and a correct diagnosis of 90.1%. Our results show that MT-TONE-MRA is a useful non-invasive technique with improved vascular detail and vascular background for detection of intracranial aneurysm. Further technical improvements are necessary for better visualisation of pathological findings in the carotid siphon, where only 60% of the aneurysms could be clearly detected. (orig./MG) [de

  4. PIV Measurement of Wall Shear Stress and Flow Structures within an Intracranial Aneurysm Model

    Science.gov (United States)

    Chow, Ricky; Sparrow, Eph; Campbell, Gary; Divani, Afshin; Sheng, Jian

    2012-11-01

    The formation and rupture of an intracranial aneurysm (IA) is a debilitating and often lethal event. Geometric features of the aneurysm bulb and upstream artery, such as bulb size, bulb shape, and curvature of the artery, are two groups of factors that define the flow and stresses within an IA. Abnormal flow stresses are related to rupture. This presentation discusses the development of a quasi-3D PIV technique and its application in various glass models at Re = 275 and 550 to experimentally assess at a preliminary level the impact of geometry and flow rate. Some conclusions are to be drawn linking geometry of the flow domain to rupture risk. The extracted results also serve as the baseline case and as a precursor to a companion presentation by the authors discussing the impact of flow diverters, a new class of medical devices. The PIV experiments were performed in a fully index-matched flow facility, allowing for unobstructed observations over complex geometry. A reconstruction and analysis method was devised to obtain 3D mean wall stress distributions and flow fields. The quasi 3D measurements were reconstructed from orthogonal planes encompassing the entire glass model, spaced 0.4mm apart. Wall shear stresses were evaluated from the near-wall flow viscous stresses.

  5. The predictive role of health-promoting behaviours and perceived stress in aneurysmal rupture.

    Science.gov (United States)

    Lee, Mi-Sun; Park, Chang G; Hughes, Tonda L; Jun, Sang-Eun; Whang, Kum; Kim, Nahyun

    2018-03-01

    To examine the roles of two modifiable factors-health-promoting behaviours and perceived stress-in predicting aneurysmal rupture. Unruptured intracranial aneurysm detection produces significant stress and anxiety in patients because of the risk of rupture. Compared to nonmodifiable risk factors for rupture such as age, gender and aneurysm size/location, less attention has been given to modifiable risk factors. Two modifiable factors, health-promoting behaviours and perceived stress, have hardly been examined as potential predictors of rupture. This study used a cross-sectional design. We assessed 155 patients with intracranial aneurysms-that is, subarachnoid haemorrhage (n = 77) or unruptured intracranial aneurysm (n = 78)-to examine (i) baseline characteristics (patient and aneurysmal factors), (ii) health-related factors (lifestyle habits and health-promoting behaviour) and (iii) perceived stress levels (psychological stress and physical stress). Patient records provided medical histories and aneurysmal factors; other data were collected using a structured questionnaire addressing lifestyle habits, the Health-Promoting Lifestyle Profile-II to measure health-promoting behaviour and the Perceived Stress Questionnaire to measure perceived-psychological stress and perceived-physical stress levels. Bivariate analysis indicated that aneurysm rupture risk was associated with female gender, aneurysm size/location, defecation frequency, hyperlipidaemia, sedentary time, low Health-Promoting Lifestyle Profile-II mean scores and high perceived-psychological stress scores. After adjusting for known risk factors, the mean Health-Promoting Lifestyle Profile-II and perceived-psychological stress scores remained robust predictors of rupture. Furthermore, known risk factors combined with these scores had greater predictive power than known risk factors alone. Health-promoting behaviour and psychological stress are promising modifiable factors for reducing risk of aneurysmal

  6. Novel genetic loci underlying human intracranial volume identified through genome-wide association

    OpenAIRE

    Adams, Hieab HH; Hibar, Derrek P; Chouraki, Vincent; Stein, Jason L; Nyquist, Paul A; Renter��a, Miguel E; Trompet, Stella; Arias-Vasquez, Alejandro; Seshadri, Sudha; Desrivi��res, Sylvane; Beecham, Ashley H; Jahanshad, Neda; Wittfeld, Katharina; Van der Lee, Sven J; Abramovic, Lucija

    2016-01-01

    Intracranial volume reflects the maximally attained brain size during development, and remains stable with loss of tissue in late life. It is highly heritable, but the underlying genes remain largely undetermined. In a genome-wide association study of 32,438 adults, we discovered five previously unknown loci for intracranial volume and confirmed two known signals. Four of the loci were also associated with adult human stature, but these remained associated with intracranial volume after adjus...

  7. Epidemiology, genetic, natural history and clinical presentation of giant cerebral aneurysms.

    Science.gov (United States)

    Lonjon, M; Pennes, F; Sedat, J; Bataille, B

    2015-12-01

    Giant cerebral aneurysms represent 5% of intracranial aneurysms, and become symptomatic between 40 and 70 years with a female predominance. In the paediatric population, the giant aneurysm rate is higher than in the adult population. Classified as saccular, fusiform and serpentine, the natural history of giant cerebral aneurysms is characterized by thrombosis, growth and rupture. The pathogenesis of these giant aneurysms is influenced by a number of risk factors, including genetic variables. Genome-wide association studies have identified some chromosomes highlighting candidate genes. Although these giant aneurysms can occur at the same locations as their smaller counterparts, a predilection for the cavernous location has been observed. Giant aneurysms present with symptoms caused by a mass effect depending on their location or by rupture; ischemic manifestations rarely reveal the aneurysm. If the initial clinical descriptions have been back up by imagery, the clinical context with a pertinent analysis of the risk factors remain the cornerstone for the management decisions of these lesions. Five year cumulative rupture rates for patients with giant aneurysm were 40% for those located on the anterior part of circle of Willis and 50% for those on the posterior part. The poor outcome of untreated patients justifies the therapeutic risks. Copyright © 2015. Published by Elsevier Masson SAS.

  8. Time-resolved imaging of contrast kinetics does not improve performance of follow-up MRA of embolized intracranial aneurysms.

    Science.gov (United States)

    Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2012-07-01

    The use of contrast media and the time-resolved imaging of contrast kinetics (TRICKS) technique have some theoretical advantages over time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. We prospectively compared the diagnostic performance of TRICKS and TOF-MRA with digital subtracted angiography (DSA) in the assessment of occlusion of embolized aneurysms. Seventy-two consecutive patients with 72 aneurysms were examined 3 months after embolization. Test characteristics of TOF-MRA and TRICKS were calculated for the detection of residual flow. The results of quantification of flow were compared with weighted kappa. Intraobserver and interobserver reproducibility was determined. The sensitivity of TOF-MRA was 85% (95% CI, 65-96%) and of TRICKS, 89% (95% CI, 70-97%). The specificity of both methods was 91% (95% CI, 79-98%). The accuracy of the flow quantification ranged from 0.76 (TOF-MRA) to 0.83 (TRICKS). There was no significant difference between the methods in the area under the ROC curve regarding both the detection and the quantification of flow. Intraobserver reproducibility was very good with both techniques (kappa, 0.86-0.89). The interobserver reproducibility was moderate for TOF-MRA and very good for TRICKS (kappa, 0.74-0.80). In this study, TOF-MRA and TRICKS presented similar diagnostic performance; therefore, the use of time-resolved contrast-enhanced MRA is not justified in the follow-up of embolized aneurysms.

  9. Association between hemodynamic modifications and clinical outcome of intracranial aneurysms treated using flow diverters.

    Science.gov (United States)

    Paliwal, Nikhil; Damiano, Robert J; Davies, Jason M; Siddiqui, Adnan H; Meng, Hui

    2017-02-11

    Treatment of intracranial aneurysms (IAs) has been revolutionized by the advent of endovascular Flow Diverters (FDs), which disrupt blood flow within the aneurysm to induce pro-thrombotic conditions, and serves as a scaffold for endothelial ingrowth and arterial remodeling. Despite good clinical success of FDs, complications like incomplete occlusion and post-treatment rupture leading to subarachnoid hemorrhage have been reported. In silico computational fluid dynamic analysis of the pre- and post-treated geometries of IA patients can shed light on the contrasting blood hemodynamics associated with different clinical outcomes. In this study, we analyzed hemodynamic modifications in 15 IA patients treated using a single FD; 10 IAs were completely occluded (successful) and 5 were partially occluded (unsuccessful) at 12-month follow-up. An in-house virtual stenting workflow was used to recapitulate the clinical intervention on these cases, followed by CFD to obtain pre- and post-treatment hemodynamics. Bulk hemodynamic parameters showed comparable reductions in both groups with average inflow rate and aneurysmal velocity reduction of 40.3% and 52.4% in successful cases, and 34.4% and 49.2% in unsuccessful cases. There was a substantial reduction in localized parameter like vortex coreline length and Energy Loss for successful cases, 38.2% and 42.9% compared to 10.1% and 10.5% for unsuccessful cases. This suggest that for successfully treated IAs, the localized complex blood flow is disrupted more prominently by the FD as compared to unsuccessful cases. These localized hemodynamic parameters can be potentially used in prediction of treatment outcome, thus aiding the clinicians in a priori assessment of different treatment strategies.

  10. Application of Revasculization Technique in Aneurysm Surgery : Kyorin University Experience

    OpenAIRE

    栗田, 浩樹; 山口, 竜一; 池田, 俊貴; 原田, 洋一; 塩川, 芳昭; Hiroki, KURITA; Ryuichi, YAMAGUCHI; Toshiki, IKEDA; Youichi, HARADA; Yoshiaki, SHIOKAWA; 杏林大学医学部脳神経外科・脳卒中センター; 杏林大学医学部脳神経外科・脳卒中センター; 杏林大学医学部脳神経外科・脳卒中センター; 杏林大学医学部脳神経外科・脳卒中センター; 杏林大学医学部脳神経外科・脳卒中センター

    2008-01-01

    Between February 2004 and September 2005, revasculization technique was used in 10 patients with intracranial aneurysm to obliterate the aneurysm and to prevent ischemic complications. Five high-flow external carotid-internal carotid (EC-IC) bypasses with radial artery graft (EC-RA-M2) followed by proximal IC occlusion/trapping were used to obliterate unruptured IC-cavernous large/giant aneurysms and ruptured IC anterior wall aneurysms. One patient with ruptured VA-union dissecting aneurysm w...

  11. Microneurosurgical management of anterior choroid artery aneurysms.

    Science.gov (United States)

    Lehecka, Martin; Dashti, Reza; Laakso, Aki; van Popta, Jouke S; Romani, Rossana; Navratil, Ondrej; Kivipelto, Leena; Kivisaari, Riku; Foroughi, Mansoor; Kokuzawa, Jouji; Lehto, Hanna; Niemelä, Mika; Rinne, Jaakko; Ronkainen, Antti; Koivisto, Timo; Jääskelainen, Juha E; Hernesniemi, Juha

    2010-05-01

    Anterior choroid artery aneurysms (AChAAs) constitute 2%-5% of all intracranial aneurysms. They are usually small, thin walled with one or several arteries originating at their base, and often associated with multiple aneurysms. In this article, we review the practical microsurgical anatomy, the preoperative imaging, surgical planning, and the microneurosurgical steps in the dissection and the clipping of AChAAs. This review, and the whole series on intracranial aneurysms (IAs), are mainly based on the personal microneurosurgical experience of the senior author (J.H.) in two Finnish centers (Helsinki and Kuopio) that serve, without patient selection, the catchment area in Southern and Eastern Finland. These two centers have treated more than 10,000 patients with IAs since 1951. In the Kuopio Cerebral Aneurysm Database of 3005 patients with 4253 IAs, 831 patients (28%) had altogether 980 internal carotid artery (ICA) aneurysms, of whom 95 patients had 99 (2%) AChAAs. Ruptured AChAAs, found in 39 patients (41%), with median size of 6 mm (range = 2-19 mm), were associated with intracerebral hematoma (ICH) in only 1 (3%) patient. Multiple aneurysms were seen in 58 (61%) patients. The main difficulty in microneurosurgical management of AChAAs is to preserve flow in the anterior choroid artery originating at the base and often attached to the aneurysm dome. This necessitates perfect surgical strategy based on preoperative knowledge of 3 dimensional angioarchitecture and proper orientation during the microsurgical dissection. Copyright © 2010 Elsevier Inc. All rights reserved.

  12. Experimental Study of Flow Through Carotid Aneurysms

    Science.gov (United States)

    Masoomi, Faezeh; Mejia-Alvarez, Ricardo

    2017-11-01

    There is evidence that traditional endovascular techniques like coiling are not effective for treatment of wide-neck cerebral aneurysms. Flow Diverter Stents (FDS) have emerged as promising devices for treating complex aneurysms since they enable treatment of aneurysms that were considered untreatable before. Recent studies suggest a number of associated risks with FDS, including in-stent thrombosis, perianeurysmal edema, delayed hemorrhage, and perforator occlusions. Chong et al. simulated hemodynamic behavior using patient-specific data. From their study, it is possible to infer that the standard deviation of energy loss could be a good predictor for intervention success. The aim of this study is to investigate the flow in models of cerebral aneurysms before and after FDS insertion using PIV. These models will be based on actual clinical studies and will be fabricated with advanced additive manufacturing techniques. These data will then be used to explore flow parameters that could inform the likelihood of post-intervention aneurysm rupture, and help determine FDS designs that better suit any particular patient before its procedure.

  13. Inflammatory Mediators in Vascular Disease: Identifying Promising Targets for Intracranial Aneurysm Research

    Directory of Open Access Journals (Sweden)

    David M. Sawyer

    2015-01-01

    Full Text Available Inflammatory processes are implicated in many diseases of the vasculature and have been shown to play a key role in the formation of intracranial aneurysms (IAs. Although the specific mechanisms underlying these processes have been thoroughly investigated in related pathologies, such as atherosclerosis, there remains a paucity of information regarding the immunopathology of IA. Cells such as macrophages and lymphocytes and their effector molecules have been suggested to be players in IA, but their specific interactions and the role of other components of the inflammatory response have yet to be determined. Drawing parallels between the pathogenesis of IA and other vascular disorders could provide a roadmap for developing a mechanistic understanding of the immunopathology of IA and uncovering useful targets for therapeutic intervention. Future research should address the presence and function of leukocyte subsets, mechanisms of leukocyte recruitment and activation, and the role of damage-associated molecular patterns in IA.

  14. Circulating neutrophil transcriptome may reveal intracranial aneurysm signature.

    Directory of Open Access Journals (Sweden)

    Vincent M Tutino

    Full Text Available Unruptured intracranial aneurysms (IAs are typically asymptomatic and undetected except for incidental discovery on imaging. Blood-based diagnostic biomarkers could lead to improvements in IA management. This exploratory study examined circulating neutrophils to determine whether they carry RNA expression signatures of IAs.Blood samples were collected from patients receiving cerebral angiography. Eleven samples were collected from patients with IAs and 11 from patients without IAs as controls. Samples from the two groups were paired based on demographics and comorbidities. RNA was extracted from isolated neutrophils and subjected to next-generation RNA sequencing to obtain differential expressions for identification of an IA-associated signature. Bioinformatics analyses, including gene set enrichment analysis and Ingenuity Pathway Analysis, were used to investigate the biological function of all differentially expressed transcripts.Transcriptome profiling identified 258 differentially expressed transcripts in patients with and without IAs. Expression differences were consistent with peripheral neutrophil activation. An IA-associated RNA expression signature was identified in 82 transcripts (p<0.05, fold-change ≥2. This signature was able to separate patients with and without IAs on hierarchical clustering. Furthermore, in an independent, unpaired, replication cohort of patients with IAs (n = 5 and controls (n = 5, the 82 transcripts separated 9 of 10 patients into their respective groups.Preliminary findings show that RNA expression from circulating neutrophils carries an IA-associated signature. These findings highlight a potential to use predictive biomarkers from peripheral blood samples to identify patients with IAs.

  15. Evaluation of occurring complications after flow diverter treatment of elastase-induced aneurysm in rabbits using micro-CT and MRI at 9.4 T

    Energy Technology Data Exchange (ETDEWEB)

    Simgen, Andreas; Ley, Desiree; Muehl-Benninghaus, Ruben; Koerner, Heiko; Reith, Wolfgang; Yilmaz, Umut [Saarland University Hospital, Department of Neuroradiology, Homburg, Saar (Germany); Roth, Christian [Clinic Bremen-Mitte, Department of Neuroradiology, Bremen (Germany); Cattaneo, Giorgio Franco Maria [Acandis GmbH, Pforzheim (Germany); Mueller, Andreas [Saarland University Hospital, Department of Experimental Surgery, Homburg, Saar (Germany); Kim, Yoo-Jin [Saarland University Hospital, Department of Pathology, Homburg, Saar (Germany); Scheller, Bruno [Saarland University Hospital, Department of Cardiology, Homburg, Saar (Germany)

    2016-10-15

    Flow diverters are increasingly being used to treat intracranial aneurysms. This study evaluates occurring complications of flow-diverting devices in the treatment of experimental aneurysms, involving the use of micro-CT and small animal MRI at 9.4 T, in correlation to angiographic and histological findings. We previously published two preclinical studies, in which we assessed two different flow diverters in the treatment of elastase-induced aneurysms. Devices have been implanted across the aneurysm neck as well as in the abdominal aorta. From these studies, a total of 65 devices (prototype FD (n = 30) and Derivo embolization device (n = 35)) additionally underwent micro-CT and MRI after angiographic follow-up and before being histologically examined. The different architectures of both devices were precisely comparable due to high-resolution micro-CT imaging. Micro-CT revealed wire fractures in nine cases (30 %) only with the prototype FD. In three cases (10 %), severe wire fractures correlated with an in-stent stenosis due to intimal hyperplasia. Other complications, like distal stent occlusions and post-stent stenosis, were seen in both groups and verified with both imaging techniques. Osseous metaplasia were correlated to calcifications seen with micro-CT. MRI enabled visualization of the position of the implanted devices relative to the aneurysm and revealed incomplete aneurysm neck coverage with the prototype FD in two cases (6.7 %). Micro-CT and 9.4-T MRI are valid to discover and understand occurring complications of flow diverters in the preclinical phase and can serve as evaluation tools to minimize complication rates of endovascular devices in the future. (orig.)

  16. Patient radiation dose in diagnostic and interventional procedures for intracranial aneurysms: Experience at a single center

    International Nuclear Information System (INIS)

    Chun, Chang Woo; Kim, Bum Soo; Lee, Cheol Hyoun; Ihn, Yon Kwon; Shin, Yong Sam

    2014-01-01

    To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms in a large sample size from a single center. We studied a sample of 439 diagnostic and 149 therapeutic procedures for intracranial aneurysms in 480 patients (331 females, 149 males; median age, 57 years; range, 21-88 years), which were performed in 2012 with a biplane unit. Parameters including fluoroscopic time, dose-area product (DAP), and total angiographic image frames were obtained and analyzed. Mean fluoroscopic time, total mean DAP, and total image frames were 12.6 minutes, 136.6 +/- 44.8 Gy-cm 2 , and 251 +/- 49 frames for diagnostic procedures, 52.9 minutes, 226.0 +/- 129.2 Gy-cm 2 , and 241 frames for therapeutic procedures, and 52.2 minutes, 334.5 +/- 184.6 Gy-cm 2 , and 408 frames for when both procedures were performed during the same session. The third quartiles for diagnostic reference levels (DRLs) were 14.0, 61.1, and 66.1 minutes for fluoroscopy time, 154.2, 272.8, and 393.8 Gy-cm 2 for DAP, and 272, 276, and 535 for numbers of image frames in diagnostic, therapeutic, and both procedures in the same session, respectively. The proportions of fluoroscopy in DAP for the procedures were 11.4%, 50.5%, and 36.1%, respectively, for the three groups. The mean DAP for each 3-dimensional rotational angiographic acquisition was 19.2 +/- 3.2 Gy-cm 2 . On average, rotational angiography was used 1.4 +/- 0.6 times/session (range, 1-4; n = 580). Radiation dose in our study as measured by DAP, fluoroscopy time and image frames did not differ significantly from other reported DRL studies for cerebral angiography, and DAP was lower with fewer angiographic image frames for embolization. A national registry of radiation-dose data is a necessary next step to refine the dose reference level.

  17. Clipping treatment of posterior communicating artery aneurysms associated with arteriosclerosis and calcification: A single center study of 136 cases.

    Science.gov (United States)

    Shi, Lei; Yu, Jing; Zhao, Ying; Xu, Kan; Yu, Jinlu

    2018-02-01

    It is widely acknowledged that arteriosclerosis and calcification of the parent artery and aneurysm neck make it difficult to clip posterior communicating artery (PCoA) aneurysms. A total of 136 cases of PCoA aneurysms accompanied by arteriosclerosis and calcification were collected and treated with clipping in the present study. Of the 136 patients, 112 were females (82.4%) and 24 were males (17.6%), with ages ranging from 37 to 76 years (mean age, 60.2 years). Rupture of a PCoA aneurysm was identified in 132 cases (97.1%), and there were 4 cases of unruptured PCoA aneurysms (2.9%). According to the severity of arteriosclerosis and calcification, the aneurysms were divided into type I, II or III. The treatment of type I aneurysms achieved the best curative effect. It is difficult to temporarily occlude type II and III aneurysms during surgery, and temporary occlusion failed in almost 50% of cases. Types II and III were prone to intraoperative aneurysm ruptures. A significantly higher rate of intraoperative aneurysm rupture was seen in type III compared with type II cases. Type II and III cases were more likely to be treated using a fenestrated clip for aneurysm clipping compared with type I cases, and fenestrated clips were used significantly more frequently in type III cases compared with type II cases. Arteriosclerosis and calcification were likely to affect the prognosis of patients, particularly in cases with type III arteriosclerosis and calcification of the parent artery and aneurysm neck. Therefore, the stratification of the arteriosclerosis and calcification of the parent artery and aneurysm neck into types I-III can guide the intraoperative aneurysm clipping strategy, aid in choosing the correct clips, and inform predictions of the occurrence of rupture and hemorrhage, as well as the prognosis for aneurysms.

  18. Surgical clipping as the preferred treatment for aneurysms of the middle cerebral artery

    NARCIS (Netherlands)

    van Dijk, J. Marc C.; Groen, Rob J. M.; Ter Laan, Mark; Jeltema, Johanna Rinck; Mooij, Jan Jacob A.; Metzemaekers, Jan D. M.

    2011-01-01

    In recent years the endovascular treatment of intracranial aneurysms (coiling) has progressively gained recognition, particularly after the publication of the International Subarachnoid Aneurysm Trial (ISAT) in 2002. Despite the fact that in ISAT middle cerebral artery (MCA) aneurysms were clearly

  19. Association of functional MMP-2 gene variant with intracranial aneurysms: case-control genetic association study and meta-analysis.

    Science.gov (United States)

    Alg, Varinder S; Ke, Xiayi; Grieve, Joan; Bonner, Stephen; Walsh, Daniel C; Bulters, Diederik; Kitchen, Neil; Houlden, Henry; Werring, David J

    2018-01-15

    Abnormalities in Matrix Metalloproteinase (MMP) genes, which are important in extracellular matrix (ECM) maintenance and therefore arterial wall integrity are a plausible underlying mechanism of intracranial aneurysm (IA) formation, growth and subsequent rupture. We investigated whether the rs243865 C > T SNP (single nucleotide polymorphism) within the MMP-2 gene (which influences gene transcription) is associated with IA compared to matched controls. We conducted a case-control genetic association study, adjusted for known IA risk factors (smoking and hypertension), in a UK Caucasian population of 1409 patients with intracranial aneurysms (IA), and 1290 matched controls, to determine the association of the rs243865 C > T functional MMP-2 gene SNP with IA (overall, and classified as ruptured and unruptured). We also undertook a meta-analysis of two previous studies examining this SNP. The rs243865 T allele was associated with IA presence in univariate (OR 1.18 [95% CI 1.04-1.33], p = .01) and in multi-variable analyses adjusted for smoking and hypertension status (OR 1.16 [95% CI 1.01-1.35], p = .042). Subgroup analysis demonstrated an association of the rs243865 SNP with ruptured IA (OR 1.18 [95% CI 1.03-1.34] p = .017), but, not unruptured IA (OR 1.17 [95% CI 0.97-1.42], p = .11). Our study demonstrated an association between the functional MMP-2 rs243865 variant and IAs. Our findings suggest a genetic role for altered extracellular matrix integrity in the pathogenesis of IA development and rupture.

  20. Neuroprotective effect of bispectral index-guided fast-track anesthesia using sevoflurane combined with dexmedetomidine for intracranial aneurysm embolization

    Directory of Open Access Journals (Sweden)

    Chao-liang Tang

    2018-01-01

    Full Text Available Dexmedetomidine has sedative, anxiolytic, analgesic, anti-sympathetic, and anti-shivering effects. Dexmedetomidine might be effective in combination with sevoflurane for anesthesia, but prospective randomized controlled clinical trials with which to verify this hypothesis are lacking. In total, 120 patients who underwent embolization of an intracranial aneurysm were recruited from Anhui Provincial Hospital and Renmin Hospital of Wuhan University of China and randomly allocated to two groups. After intraoperative administration of 2% to 3% sevoflurane inhalation, one group of patients received pump-controlled intravenous injection of 1.0 μg/kg dexmedetomidine for 15 minutes followed by maintenance with 0.3 μg/kg/h until the end of surgery; the other group of patients only underwent pump-controlled infusion of saline. Bispectral index monitoring revealed that dexmedetomidine-assisted anesthesia can shorten the recovery time of spontaneous breathing, time to eye opening, and time to laryngeal mask removal. Before anesthetic induction and immediately after laryngeal mask airway removal, the glucose and lactate levels were low, the S100β and neuron-specific enolase levels were low, the perioperative blood pressure and heart rate were stable, and postoperative delirium was minimal. These findings indicate that dexmedetomidine can effectively assist sevoflurane for anesthesia during surgical embolization of intracranial aneurysms, shorten the time to consciousness and extubation, reduce the stress response and energy metabolism, stabilize hemodynamic parameters, and reduce adverse reactions, thereby reducing the damage to the central nervous system. This trial was registered at the Chinese Clinical Trial Registry (http://www.chictr.org.cn/ (registration number: ChiCTR-IPR-16008113.

  1. Effect of hemodynamics on outcome of subtotally occluded paraclinoid aneurysms after stent-assisted coil embolization.

    Science.gov (United States)

    Liu, Jian; Jing, Linkai; Wang, Chao; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian

    2016-11-01

    Endovascular treatment of paraclinoid aneurysms is preferred in clinical practice. Flow alterations caused by stents and coils may affect treatment outcome. To assess hemodynamic changes following stent-assisted coil embolization (SACE) in subtotally embolized paraclinoid aneurysms with residual necks that were predisposed to recanalization. We studied 27 paraclinoid aneurysms (seven recanalized and 20 stable) treated with coils and Enterprise stents. Computational fluid dynamic simulations were performed on patient-specific aneurysm geometries using virtual stenting and porous media technology. After stent placement in 27 cases, aneurysm flow velocity decreased significantly, the reduction gradually increasing from the neck plane (11.9%), to the residual neck (12.3%), to the aneurysm dome (16.3%). Subsequent coil embolization was performed after stent placement and the hemodynamic factors decreased further and significantly at all aneurysm regions except the neck plane. In a comparison of recanalized and stable cases, univariate analysis showed no significant differences in any parameter before treatment. After stent-assisted coiling, only the reduction in area-averaged velocity at the neck plane differed significantly between recanalized (8.1%) and stable cases (20.5%) (p=0.016). Aneurysm flow velocity can be significantly decreased by stent placement and coil embolization. However, hemodynamics at the aneurysm neck plane is less sensitive to coils. Significant reduction in flow velocity at the neck plane may be an important factor in preventing recanalization of paraclinoid aneurysms after subtotal SACE. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. Prediction of parent artery of anterior communicating artery aneurysm on CT angiography

    International Nuclear Information System (INIS)

    Chung, Jin Young; Han, Tae Il; Kim, Dae Hong; Han, Hyun Young; Kim, Hyun Jung; Song, Mun Kab

    1999-01-01

    To determine whether CT angiography can predict the parent artery of an anterior communicating aneurysm on the basis of characteristics of the aneurysm and precommunication anterior cerebral artery. Eighteen patients with anterior communication aneurysm were studied prospectively using CT angiography and conventional angiography. The parent artery of an aneurysm was predicted by evaluating aneurysm neck location, direction of aneurysm projection, and size of the precommunicating anterior cerebral artery, as seen on CT angiography. A somatom Plus-4 spiral CT scanner was used and shaded-surface display three-dimensional images were constructed. Aneurysm neck was located near the parent artery in 12 cases(66.7%), and aneurysm projection was against the parent artery in 11 cases(61.1%). The parent artery of the anterior cerebral artery was larger in 15 cases(83.3%), including ten cases of hypoplasia or agenesis of the contralateral anterior cerebral artery. In 17 of 18 aneurysms(94.4%) the parent artery seen on DSA was correctly predicted by CT angiography. The parent artery of an anterior communicating aneurysm can be predicted by evaluating aneurysm neck location, direction of aneurysm projection, and precommunicating anterior cerebral artery, as seen on CT angiography

  3. Brain aneurysm patients seen in Harare, Zimbabwe: cases review ...

    African Journals Online (AJOL)

    Setting: Parirenyatwa Group of Hospitals and Avenues Clinic, Harare, Zimbabwe. Subjects: Adult intracranial aneurysm patients. Interventions: Craniotomy and aneurysm clipping. Results: Seventeen patients were seen during the period of study. Twelve were female patients while five were male with a male to female ratio ...

  4. Multiple intracranial aneurysms following radiation therapy for pituitary adenoma

    International Nuclear Information System (INIS)

    Moriyama, Takumi; Shigemori, Minoru; Hirohata, Yu; Konishi, Jun; Yuge, Tatuo; Tokunaga, Takayuki; Kuramoto, Shinken.

    1992-01-01

    A rare case is reported in which multiple cerebral aneurysm occurred after radiotherapy. A female aged 51 was hospitalized with a chief complaint of consciousness disorder. The patient was discharged from the hospital 1 year before, after undergoing subtotal extirpation of a tumor through the transsphenoidal sinus in a case of pituitary adenoma, and post-operative radiotherapy (topical 50 Gy). Mild hyperlipidemia associated with hypothyroidism was observed by blood biochemical test during hospitalization. Multiple cerebral infarction was observed by CT scanning and MR imaging. Conservative treatment including intensified endocrine-supplementing treatment was performed. Thyroid gland function and hyperlipidemia improved, but the consciousness disorder occurred suddenly 6 weeks after hospitalization. Subarachnoid hemorrhage and hydrocephalus were observed by CT scanning. Cerebral angiography detected a saccular aneurysm in the trifuraction of the right middle cerebral artery, 3 fusiform aneurysms in the periphery of the right middle cerebral artery, 2 fusiform aneurysms in the posterior cerebral artery. These findings were not observed at the initial hospitalization but were unexceptionally confined to all the irradiation fields. The patient died 8 weeks after hospitalization, and no autoptic findings was obtained. We presumed that radiation vasculopathy, caused by radiation therapy done one year previously, had led to the occurrence of multiple cerebral aneurysms. We think that hyperlipidemia may have acted as an exacerbating factor responsible for these aneurysms. (author)

  5. Endovascular coil embolization for anterior choroidal artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Moon; Chung, Eun Chul [Sungkyunkwan University School of Medicine, Department of Radiology, Kangbuk Samsung Hospital, Seoul (Korea); Kim, Dong Ik; Kim, Dong Joon; Suh, Sang Hyun [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea); Kim, Sun Yong [Ajou University College of Medicine, Department of Radiology, Suwon (Korea); Shin, Yong Sam [Ajou University College of Medicine, Department of Neurosurgery, Suwon (Korea); Park, Sung Il [Soonchunhyang University College of Medicine, Department of Radiology, Bucheon Hospital, Bucheon (Korea); Choi, Chun Sik; Won, Yu.Sam [Sungkyunkwan University School of Medicine, Department of Neurosurgery, Kangbuk Samsung Hospital, Seoul (Korea)

    2008-03-15

    We retrospectively evaluated the ischemic complications related to the anterior choroidal artery (AChA) and clinical outcome after coiling of AChA aneurysms. We included 37 patients (27 with subarachnoid hemorrhage, 10 without) harboring 38 AChA aneurysms (23 ruptured, 15 unruptured) who were treated by coiling at four institutions. Ischemic complications related to the AChA and clinical outcomes were retrospectively evaluated. Intraprocedural transient AChA occlusion occurred in five aneurysms, all of which had AChA incorporated into the aneurysm neck. Two of the five patients suffered postprocedural transient contralateral hemiparesis, but recovered completely. The remaining three patients had no postprocedural symptoms. Incidence of transient AChA occlusion was significantly higher in those aneurysms in which the AChA was incorporated into aneurysm neck (group 2) than in those in which the AChA was not incorporated (group 1). Of the 37 patients, 31 (83.8%) had good recoveries (modified Rankin scale score 0-2). Two patients died from the consequences of subarachnoid hemorrhage. During follow-up for a mean of 27 months (range 4-72 months), none of the 35 living patients re-bled. A total of 29 aneurysms in 28 patients were followed-up angiographically. Recurrences were found in 5 of the 29 aneurysms during follow-up (mean 18 months, range 6-45 months). Re-embolization achieved near complete occlusion of two recurrent aneurysms, both of which were still stable at the time of the next two follow-up angiographies. The other three recurrent aneurysms were not retreated due to the small size of the recurrences. Coiling of AChA aneurysms resulted in good outcomes without AChA-related permanent ischemic complications. Transient AChA occlusion, potentially associated with ischemic complications, was significantly more frequent in the aneurysm in which the AChA was incorporated into the aneurysm neck. (orig.)

  6. Maffucci's syndrome associated with chondrosarcoma and aneurysm: case report

    International Nuclear Information System (INIS)

    Lim, Hyoung Gun; Yoo, Won Jong; Lim, Yeon Soo; Sung, Mi Sook; Chung, Myung Hee; Lee, Hae Giu; Jung, So Lyung; Kim, Jae Na

    2002-01-01

    Maffucci syndrome is rare congenital non-inherited condition characterized by multiple enchondromas and cutaneous hemangiomas. It is associated with increased risk of malignancy, including chondrosarcomas, and because of generalized mesodermal dysplasia, aneurysms can develop. We present a case of maffucci syndrome associated with intracranial chondrosarcoma and aneurysm

  7. Nonsphericity Index and Size Ratio Identify Morphologic Differences between Growing and Stable Aneurysms in a Longitudinal Study of 93 Cases.

    Science.gov (United States)

    Chien, A; Xu, M; Yokota, H; Scalzo, F; Morimoto, E; Salamon, N

    2018-01-25

    Recent studies have strongly associated intracranial aneurysm growth with increased risk of rupture. Identifying aneurysms that are likely to grow would be beneficial to plan more effective monitoring and intervention strategies. Our hypothesis is that for unruptured intracranial aneurysms of similar size, morphologic characteristics differ between aneurysms that continue to grow and those that do not. From aneurysms in our medical center with follow-up imaging dates in 2015, ninety-three intracranial aneurysms (23 growing, 70 stable) were selected. All CTA images for the aneurysm diagnosis and follow-up were collected, a total of 348 3D imaging studies. Aneurysm 3D geometry for each imaging study was reconstructed, and morphologic characteristics, including volume, surface area, nonsphericity index, aspect ratio, and size ratio were calculated. Morphologic characteristics were found to differ between growing and stable groups. For aneurysms of 7 mm, volume ( P differ between those that are growing and those that are stable. The nonsphericity index, in particular, was found to be higher among growing aneurysms. The size ratio was found to be the second most significant parameter associated with growth. © 2018 by American Journal of Neuroradiology.

  8. Characteristics of intracranial aneurysms in the else kröner-fresenius registry of autosomal dominant polycystic kidney disease.

    Science.gov (United States)

    Neumann, Hartmut P H; Malinoc, Angelica; Bacher, Janina; Nabulsi, Zinaida; Ivanovas, Vera; Bruechle, Nadine Ortiz; Mader, Irina; Hoffmann, Michael M; Riegler, Peter; Kraemer-Guth, Annette; Burchardi, Christian; Schaeffner, Elke; Martin, Rodolfo S; Azurmendi, Pablo J; Zerres, Klaus; Jilg, Cordula; Eng, Charis; Gläsker, Sven

    2012-01-01

    Patients who harbor intracranial aneurysms (IAs) run a risk for aneurysm rupture and subsequent subarachnoid hemorrhage which frequently results in permanent deficits or death. Prophylactic treatment of unruptured aneurysms is possible and recommended depending on the size and location of the aneurysm as well as patient age and condition. IAs are major manifestations of autosomal dominant polycystic kidney disease (ADPKD). Current guidelines do not suggest surveillance of IAs in ADPKD except in the setting of family history if IA was known in any relative with ADPKD. Management of IAs in ADPKD is problematic because limited data exist from large studies. We established the Else Kröner-Fresenius Registry for ADPKD in Germany. Clinical data were assessed for age at diagnosis of IAs, stage of renal insufficiency, and number, location and size of IAs as well as family history of cerebral events. Patients with symptomatic or asymptomatic IAs were included. All patients with ADPKD-related IAs were offered mutation scanning of the susceptibility genes for ADPKD, the PKD1 and PKD2 genes. Of 463 eligible ADPKD patients from the population base of Germany, 32 (7%) were found to have IAs, diagnosed at the age of 2-71 years, 19 females and 13 males. Twenty (63%) of these 32 patients were symptomatic, whereas IAs were detected in an asymptomatic stage in 12 patients. IAs were multifocal in 12 and unifocal in 20 patients. In 26 patients (81%), IAs were diagnosed before end-stage renal failure. Twenty-five out of 27 unrelated index cases (93%) had no IAs or cerebral events documented in their relatives with ADPKD. In 16 unrelated index patients and 3 relatives, we detected germline mutations. The mutations were randomly distributed across the PKD1 gene in 14 and the PKD2 gene in 2 index cases. Questionnaires answered for 320/441 ADPKD patients without IAs revealed that only 45/320 (14%) had MR angiography. In ADPKD, rupture of IAs occurs frequently before the start of dialysis

  9. Characteristics of Intracranial Aneurysms in the Else Kröner-Fresenius Registry of Autosomal Dominant Polycystic Kidney Disease

    Science.gov (United States)

    Neumann, Hartmut P.H.; Malinoc, Angelica; Bacher, Janina; Nabulsi, Zinaida; Ivanovas, Vera; Bruechle, Nadine Ortiz; Mader, Irina; Hoffmann, Michael M.; Riegler, Peter; Kraemer-Guth, Annette; Burchardi, Christian; Schaeffner, Elke; Martin, Rodolfo S.; Azurmendi, Pablo J.; Zerres, Klaus; Jilg, Cordula; Eng, Charis; Gläsker, Sven

    2012-01-01

    Background Patients who harbor intracranial aneurysms (IAs) run a risk for aneurysm rupture and subsequent subarachnoid hemorrhage which frequently results in permanent deficits or death. Prophylactic treatment of unruptured aneurysms is possible and recommended depending on the size and location of the aneurysm as well as patient age and condition. IAs are major manifestations of autosomal dominant polycystic kidney disease (ADPKD). Current guidelines do not suggest surveillance of IAs in ADPKD except in the setting of family history if IA was known in any relative with ADPKD. Management of IAs in ADPKD is problematic because limited data exist from large studies. Methods We established the Else Kröner-Fresenius Registry for ADPKD in Germany. Clinical data were assessed for age at diagnosis of IAs, stage of renal insufficiency, and number, location and size of IAs as well as family history of cerebral events. Patients with symptomatic or asymptomatic IAs were included. All patients with ADPKD-related IAs were offered mutation scanning of the susceptibility genes for ADPKD, the PKD1 and PKD2 genes. Results Of 463 eligible ADPKD patients from the population base of Germany, 32 (7%) were found to have IAs, diagnosed at the age of 2–71 years, 19 females and 13 males. Twenty (63%) of these 32 patients were symptomatic, whereas IAs were detected in an asymptomatic stage in 12 patients. IAs were multifocal in 12 and unifocal in 20 patients. In 26 patients (81%), IAs were diagnosed before end-stage renal failure. Twenty-five out of 27 unrelated index cases (93%) had no IAs or cerebral events documented in their relatives with ADPKD. In 16 unrelated index patients and 3 relatives, we detected germline mutations. The mutations were randomly distributed across the PKD1 gene in 14 and the PKD2 gene in 2 index cases. Questionnaires answered for 320/441 ADPKD patients without IAs revealed that only 45/320 (14%) had MR angiography. Conclusion In ADPKD, rupture of IAs occurs

  10. Characteristics of Intracranial Aneurysms in the Else Kröner-Fresenius Registry of Autosomal Dominant Polycystic Kidney Disease

    Directory of Open Access Journals (Sweden)

    Hartmut P.H. Neumann

    2012-10-01

    Full Text Available Background: Patients who harbor intracranial aneurysms (IAs run a risk for aneurysm rupture and subsequent subarachnoid hemorrhage which frequently results in permanent deficits or death. Prophylactic treatment of unruptured aneurysms is possible and recommended depending on the size and location of the aneurysm as well as patient age and condition. IAs are major manifestations of autosomal dominant polycystic kidney disease (ADPKD. Current guidelines do not suggest surveillance of IAs in ADPKD except in the setting of family history if IA was known in any relative with ADPKD. Management of IAs in ADPKD is problematic because limited data exist from large studies. Methods: We established the Else Kröner-Fresenius Registry for ADPKD in Germany. Clinical data were assessed for age at diagnosis of IAs, stage of renal insufficiency, and number, location and size of IAs as well as family history of cerebral events. Patients with symptomatic or asymptomatic IAs were included. All patients with ADPKD-related IAs were offered mutation scanning of the susceptibility genes for ADPKD, the PKD1 and PKD2 genes. Results: Of 463 eligible ADPKD patients from the population base of Germany, 32 (7% were found to have IAs, diagnosed at the age of 2–71 years, 19 females and 13 males. Twenty (63% of these 32 patients were symptomatic, whereas IAs were detected in an asymptomatic stage in 12 patients. IAs were multifocal in 12 and unifocal in 20 patients. In 26 patients (81%, IAs were diagnosed before end-stage renal failure. Twenty-five out of 27 unrelated index cases (93% had no IAs or cerebral events documented in their relatives with ADPKD. In 16 unrelated index patients and 3 relatives, we detected germline mutations. The mutations were randomly distributed across the PKD1 gene in 14 and the PKD2 gene in 2 index cases. Questionnaires answered for 320/441 ADPKD patients without IAs revealed that only 45/320 (14% had MR angiography. Conclusion: In ADPKD

  11. Maffucci's syndrome associated with chondrosarcoma and aneurysm: case report

    International Nuclear Information System (INIS)

    Lim, Hyoung Gun; Yoo, Won Jong; Lim, Yeon Soo; Sung, Mi Sook; Chung Myung Hee; Lee, Hae Giu; Jung, So Lyung; Kim, Jea NA

    2002-01-01

    Maffucci syndrome is a rare congenital non-inherited condition characterized by multiple enchondromas and cutaneous hemangiomas. It is associated with increased risk of malignancy, including chondrosarcomas, and because of generalized mesodermal dysplasia, aneurysms can develop. We present a case of Maffucci syndrome associated with intracranial chondrosarcoma and aneurysm

  12. Familial intracranial aneurysms: is anatomic vulnerability heritable?

    Science.gov (United States)

    Mackey, Jason; Brown, Robert D; Moomaw, Charles J; Hornung, Richard; Sauerbeck, Laura; Woo, Daniel; Foroud, Tatiana; Gandhi, Dheeraj; Kleindorfer, Dawn; Flaherty, Matthew L; Meissner, Irene; Anderson, Craig; Rouleau, Guy; Connolly, E Sander; Deka, Ranjan; Koller, Daniel L; Abruzzo, Todd; Huston, John; Broderick, Joseph P

    2013-01-01

    Previous studies have suggested that family members with intracranial aneurysms (IAs) often harbor IAs in similar anatomic locations. IA location is important because of its association with rupture. We tested the hypothesis that anatomic susceptibility to IA location exists using a family-based IA study. We identified all affected probands and first-degree relatives (FDRs) with a definite or probable phenotype in each family. We stratified each IA of the probands by major arterial territory and calculated each family's proband-FDR territory concordance and overall contribution to the concordance analysis. We then matched each family unit to an unrelated family unit selected randomly with replacement and performed 1001 simulations. The median concordance proportions, odds ratios (ORs), and P values from the 1001 logistic regression analyses were used to represent the final results of the analysis. There were 323 family units available for analysis, including 323 probands and 448 FDRs, with a total of 1176 IAs. IA territorial concordance was higher in the internal carotid artery (55.4% versus 45.6%; OR, 1.54 [1.04-2.27]; P=0.032), middle cerebral artery (45.8% versus 30.5%; OR, 1.99 [1.22-3.22]; P=0.006), and vertebrobasilar system (26.6% versus 11.3%; OR, 2.90 [1.05-8.24], P=0.04) distributions in the true family compared with the comparison family. Concordance was also higher when any location was considered (53.0% versus 40.7%; OR, 1.82 [1.34-2.46]; PIA development, we found that IA territorial concordance was higher when probands were compared with their own affected FDRs than with comparison FDRs, which suggests that anatomic vulnerability to IA formation exists. Future studies of IA genetics should consider stratifying cases by IA location.

  13. Medical devices of the head, neck, and spine.

    Science.gov (United States)

    Hunter, Tim B; Yoshino, Mark T; Dzioba, Robert B; Light, Rick A; Berger, William G

    2004-01-01

    There are many medical devices used for head, neck, and spinal diseases and injuries, and new devices are constantly being introduced. Many of the newest devices are variations on a previous theme. Knowing the specific name of a device is not important. It is important to recognize the presence of a device and to have an understanding of its function as well as to be able to recognize the complications associated with its use. The article discusses the most common and important devices of the head, neck, and spine, including cerebrospinal fluid shunts and the Codman Hakim programmable valve; subdural drainage catheters, subdural electrodes, intracranial electrodes, deep brain stimulators, and cerebellar electrodes; coils, balloons, adhesives, particles, and aneurysm clips; radiation therapy catheters, intracranial balloons for drug installation, and carmustine wafers; hearing aids, cochlear implants, and ossicular reconstruction prostheses; orbital prostheses, intraocular silicone oil, and lacrimal duct stents; anterior and posterior cervical plates, posterior cervical spine wiring, odontoid fracture fixation devices, cervical collars and halo vests; thoracic and lumbar spine implants, anterior and posterior instrumentation for the thoracic and lumbar spine, vertebroplasty, and artificial disks; spinal column stimulators, bone stimulators, intrathecal drug delivery pumps, and sacral stimulators; dental and facial implant devices; gastric and tracheal tubes; vagus nerve stimulators; lumboperitoneal shunts; and temperature- and oxygen-sensing probes. Copyright RSNA, 2004

  14. De novo giant A2 aneurysm following anterior communicating artery occlusion.

    Science.gov (United States)

    Ibrahim, Tarik F; Hafez, Ahmad; Andrade-Barazarte, Hugo; Raj, Rahul; Niemela, Mika; Lehto, Hanna; Numminen, Jussi; Jarvelainen, Juha; Hernesniemi, Juha

    2015-01-01

    De novo intracranial aneurysms are reported to occur with varying incidence after intracranial aneurysm treatment. They are purported to be observed, however, with increased incidence after Hunterian ligation; particularly in cases of carotid artery occlusion for giant or complex aneurysms deemed unclippable. We report a case of right-sided de novo giant A2 aneurysm 6 years after an anterior communicating artery (ACoA) aneurysm clipping. We believe this de novo aneurysm developed in part due to patient-specific risk factors but also a significant change in cerebral hemodynamics. The ACoA became occluded after surgery that likely altered the cerebral hemodynamics and contributed to the de novo aneurysm. We believe this to be the first reported case of a giant de novo aneurysm in this location. Following parent vessel occlusion (mostly of the carotid artery), there are no reports of any de novo aneurysms in the pericallosal arteries let alone a giant one. The patient had a dominant right A1 and the sudden increase in A2 blood flow likely resulted in increased wall shear stress, particularly in the medial wall of the A2 where the aneurysm occurred 2 mm distal to the A1-2 junction. ACoA preservation is a key element of aneurysm surgery in this location. Suspected occlusion of this vessel may warrant closer radiographic follow-up in patients with other risk factors for aneurysm development.

  15. Morphological and Hemodynamic Discriminators for Rupture Status in Posterior Communicating Artery Aneurysms

    OpenAIRE

    Lv, Nan; Wang, Chi; Karmonik, Christof; Fang, Yibin; Xu, Jinyu; Yu, Ying; Cao, Wei; Liu, Jianmin; Huang, Qinghai

    2016-01-01

    Background and Purpose The conflicting findings of previous morphological and hemodynamic studies on intracranial aneurysm rupture may be caused by the relatively small sample sizes and the variation in location of the patient-specific aneurysm models. We aimed to determine the discriminators for aneurysm rupture status by focusing on only posterior communicating artery (PCoA) aneurysms. Materials and Methods In 129 PCoA aneurysms (85 ruptured, 44 unruptured), clinical, morphological and hemo...

  16. Radiographic features and endovascular treatment of giant serpentine aneurysms (report of 4 cases)

    International Nuclear Information System (INIS)

    Wang Anshun

    2000-01-01

    Objective: To describe the typical CT, MRI and DSA features of intracranial giant serpentine aneurysm (GSA) and discuss the efficacy of it is the endovascular treatment. Methods: Retrograde study of 4 cases of GSA admitted and treated at the center of the present study over the last 2 years was conducted. The literature before June 1988 was reviewed. Results: The findings of CT and MRI scans of GSA resembled those of intracranial neoplasms. Cerebral angiography remained the golden diagnostic criteria for GSA. Two of cases in the present study were treated with detachable balloon occlusion of the parent artery and pre-occlusion EC-IC bypass because of insufficient cross-filling through the Willis circle found on the cross-filling symmetry test. The symptoms and signs of the two patients disappeared on 1-2 year follow-up and follow-up CT study showed no obvious change in aneurysmal size. Conclusion: The GSA is different from the intracranial giant secular or fusiform aneurysms because it has distinctive features on CT, MRI and DSA studies. GSA constitutes a subgroup of the intracranial giant aneurysms. The natural history of GSA is poor so it is necessary to give GSA aggressive management. The endovascular occlusion of the parent artery with functional EC-IC bypass is safe and effective

  17. Differential effects of chromosome 9p21 variation on subphenotypes of intracranial aneurysm: site distribution.

    Science.gov (United States)

    Nakaoka, Hirofumi; Takahashi, Tomoko; Akiyama, Koichi; Cui, Tailin; Tajima, Atsushi; Krischek, Boris; Kasuya, Hidetoshi; Hata, Akira; Inoue, Ituro

    2010-08-01

    Recently, a genome-wide association study identified associations between single nucleotide polymorphisms on chromosome 9p21 and risk of harboring intracranial aneurysm (IA). Aneurysm characteristics or subphenotypes of IAs, such as history of subarachnoid hemorrhage, presence of multiple IAs and location of IAs, are clinically important. We investigated whether the association between 9p21 variation and risk of IA varied among these subphenotypes. We conducted a case-control study of 981 cases and 699 controls in Japanese. Four single nucleotide polymorphisms tagging the 9p21 risk locus were genotyped. The OR and 95% CI were estimated using logistic regression analyses. Among the 4 single nucleotide polymorphisms, rs1333040 showed the strongest evidence of association with IA (P=1.5x10(-6); per allele OR, 1.43; 95% CI, 1.24-1.66). None of the patient characteristics (gender, age, smoking, and hypertension) was a significant confounder or effect modifier of the association. Subgroup analyses of IA subphenotypes showed that among the most common sites of IAs, the association was strongest for IAs of the posterior communicating artery (OR, 1.69; 95% CI, 1.26-2.26) and not significant for IAs in the anterior communicating artery (OR, 1.22; 95% CI, 0.96-1.57). When dichotomizing IA sites, the association was stronger for IAs of the posterior circulation-posterior communicating artery group (OR, 1.73; 95% CI, 1.32-2.26) vs the anterior circulation group (OR, 1.28; 95% CI, 1.07-1.53). Heterogeneity in these ORs was significant (P=0.032). The associations did not vary when stratifying by history of subarachnoid hemorrhage (OR, 1.42; 95% CI, 1.18-1.71 for ruptured IA; OR, 1.27; 95% CI, 1.00-1.62 for unruptured IA) or by multiplicity of IA (OR, 1.57; 95% CI, 1.21-2.03 for multiple IAs; OR, 1.36; 95% CI, 1.15-1.61 for single IA). Our results suggest that genetic influence on formation may vary between IA subphenotypes.

  18. Progressive hematoma in anterior neck after endovascular treatment of middle cerebral artery aneurysm

    Directory of Open Access Journals (Sweden)

    Aysun Ankay Yilbas

    Full Text Available Abstract Background: Cervical hematomas can lead to airway compromise, a life threatening condition, regardless of the cause. The following case is the first presentation of cervical hematoma as a complication of endovascular treatment of middle cerebral artery aneurysm. Case report: A 49 year-old woman was scheduled for stent placement under general anesthesia for middle cerebral artery aneurysm. Few days before intervention, acetyl salicylic acid and clopidogrel treatment was started. Following standard monitoring and anesthesia induction, the patient's trachea was intubated with a 7.5 mm endotracheal tube and the procedure was completed without any complications. Three hours later, dyspnea developed and physical examination revealed progressive swelling and stiffness in the neck. Endotracheal intubation was performed with a 6 mm diameter uncuffed tube with the aid of sedation. The vocal cords were completely closed due to compression. There was no leak around the endotracheal tube. The rapidly performed computerized tomography scans showed an enormous hematoma around the neck and extravasation of contrast medium through superior thyroid artery. After coil embolization of superior thyroid artery, she was taken to the intensive care unit as intubated and sedated. Surgical exploration of the hematoma was not recommended by the surgeons, because she was on clopidogrel. After two days, the patient's trachea was extubated safely ensuring that the swelling was sufficiently ceased and leak detected around the endotracheal tube. Conclusions: Securing the airway rapidly by endotracheal intubation is the most crucial point in the management of cervical hematomas. Diagnostic and therapeutic procedures should be performed only afterwards.

  19. Endovascular Aortic Aneurysm Repair for Abdominal Aortic Aneurysm: Single Center Experience in 122 Patients

    International Nuclear Information System (INIS)

    Lee, Yun Young; Song, Jang Hyeon; Kim, Yong Tae; Yim, Nam Yeol; Kim, Jae Kyu; Lee, Ho Kyun; Choi, Soo Jin Na; Chung, Sang Young; Kim, Soo Hyun; Chang, Nam Kyu

    2013-01-01

    To analyze a single center experience of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms. Results of 122 patients who underwent EVAR were analyzed, retrospectively. Sex, age, aneurysmal morphology, hostile neck anatomy, preprocedural and postprocedural sac-diameter, technical and clinical success, postprocedural complication and need of additional procedure were analyzed. A total of 111 male and 11 female patients were included. Morphology of the aneurysms was as follows: fusiform (n = 108), saccular (n = 3) and ruptured type (n = 11). Sixty-four patients had hostile neck anatomy. The preprocedural mean sac-diameter was 52.4 mm. Postprocedural sac-diameter was decreased or stable in 110 patients (90.2%) and increased in 8 patients (6.6%). Technical success rate was 100% and clinical success rate was 86.1%. Fifty-one patients showed endoleak (41.8%) and 15 patients (12.3%) underwent secondary intervention due to type I endoleak (n = 4), type II endoleak (n = 4) and stent-graft thrombosis (n = 7). EVAR is a safe and effective therapy for abdominal aortic aneurysm, and it has high technical success and clinical success rate, and low complication rate.

  20. Multiparametric MRI of intracranial aneurysms treated with the Woven EndoBridge (WEB): a case of Faraday's cage?

    Science.gov (United States)

    Nawka, Marie Teresa; Sedlacik, Jan; Frölich, Andreas; Bester, Maxim; Fiehler, Jens; Buhk, Jan-Hendrik

    2018-02-10

    To evaluate multiparametric MRI including non-contrast and contrast-enhanced morphological and angiographic techniques for intracranial aneurysms treated with the single-layer Woven EndoBridge (WEB) embolization system applying simultaneous digital subtraction angiography (DSA) as the reference of standard. We retrospectively identified all patients with incidental and acute ruptured intracranial aneurysms treated with a WEB device (WEB SL and WEB SLS) between March 2014 and June 2016 in our neurovascular center with early (within 7 days) postinterventional multiparametric MRI as well as mid-term (5-8 months) follow-up MRI and DSA available. Occlusion rates were recorded both in DSA and MR angiography (MRA). In MRI, signal intensities within the WEB as well as in the occluded dome distal to the WEB, if present, were measured by region-of-interest (ROI) analysis. Twenty-five patients fulfilled the inclusion criteria. Rates of complete/adequate occlusion at mid-term follow-up were 84% with both MRA and DSA. A strong signal loss within the WEB was observed in all MR sequences at initial and follow-up examinations. ROI analysis did not reveal significant differences in non-contrast (P=0.946) and contrast-enhanced imaging (P=0.377). A T1-hyperintense thrombus in the non-WEB-carrying dome was a frequent observation. Signal intensity measurements in multiparametric MRI suggest that neither contrast-enhanced MRA nor morphological sequences are capable of revealing reliable information on the WEB lumen, presumably due to radio frequency shielding. MRI is therefore not suitable for confirming complete thrombus formation within the WEB. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Time Course of Cerebrovascular Reactivity in Patients Treated for Unruptured Intracranial Aneurysms: A One-Year Transcranial Doppler and Acetazolamide Follow-Up Study

    Directory of Open Access Journals (Sweden)

    Marianne Lundervik Bøthun

    2018-01-01

    Full Text Available Background. Cerebrovascular reactivity (CVR is often impaired in the early phase after aneurysmal subarachnoid hemorrhage. There is, however, little knowledge about the time course of CVR in patients treated for unruptured intracranial aneurysms (UIA. Methods. CVR, assessed by transcranial Doppler and acetazolamide test, was examined within the first postoperative week after treatment for UIA and reexamined one year later. Results. Of 37 patients initially assessed, 34 were reexamined after one year. Bilaterally, baseline and acetazolamide-induced blood flow velocities were higher in the postoperative week compared with one year later (p<0.001. CVR on the ipsilateral side of treatment was lower in the initial examination compared with follow-up (58.9% versus 66.1%, p=0.04. There was no difference in CVR over time on the contralateral side (63.4% versus 65.0%, p=0.65. When mean values of right and left sides were considered there was no difference in CVR between exams. Larger aneurysm size was associated with increased change in CVR (p=0.04, and treatment with clipping was associated with 13.8%-point increased change in CVR compared with coiling (p=0.03. Conclusion. Patients with UIA may have a temporary reduction in CVR on the ipsilateral side after aneurysm treatment. The change in CVR appears more pronounced for larger-sized aneurysms and in patients treated with clipping. We recommend that ipsilateral and contralateral CVR should be assessed separately, as mean values can conceal side-differences.

  2. Novel genetic loci underlying human intracranial volume identified through genome-wide association

    Science.gov (United States)

    Adams, Hieab HH; Hibar, Derrek P; Chouraki, Vincent; Stein, Jason L; Nyquist, Paul A; Rentería, Miguel E; Trompet, Stella; Arias-Vasquez, Alejandro; Seshadri, Sudha; Desrivières, Sylvane; Beecham, Ashley H; Jahanshad, Neda; Wittfeld, Katharina; Van der Lee, Sven J; Abramovic, Lucija; Alhusaini, Saud; Amin, Najaf; Andersson, Micael; Arfanakis, Konstantinos; Aribisala, Benjamin S; Armstrong, Nicola J; Athanasiu, Lavinia; Axelsson, Tomas; Beiser, Alexa; Bernard, Manon; Bis, Joshua C; Blanken, Laura ME; Blanton, Susan H; Bohlken, Marc M; Boks, Marco P; Bralten, Janita; Brickman, Adam M; Carmichael, Owen; Chakravarty, M Mallar; Chauhan, Ganesh; Chen, Qiang; Ching, Christopher RK; Cuellar-Partida, Gabriel; Den Braber, Anouk; Doan, Nhat Trung; Ehrlich, Stefan; Filippi, Irina; Ge, Tian; Giddaluru, Sudheer; Goldman, Aaron L; Gottesman, Rebecca F; Greven, Corina U; Grimm, Oliver; Griswold, Michael E; Guadalupe, Tulio; Hass, Johanna; Haukvik, Unn K; Hilal, Saima; Hofer, Edith; Hoehn, David; Holmes, Avram J; Hoogman, Martine; Janowitz, Deborah; Jia, Tianye; Kasperaviciute, Dalia; Kim, Sungeun; Klein, Marieke; Kraemer, Bernd; Lee, Phil H; Liao, Jiemin; Liewald, David CM; Lopez, Lorna M; Luciano, Michelle; Macare, Christine; Marquand, Andre; Matarin, Mar; Mather, Karen A; Mattheisen, Manuel; Mazoyer, Bernard; McKay, David R; McWhirter, Rebekah; Milaneschi, Yuri; Mirza-Schreiber, Nazanin; Muetzel, Ryan L; Maniega, Susana Muñoz; Nho, Kwangsik; Nugent, Allison C; Olde Loohuis, Loes M; Oosterlaan, Jaap; Papmeyer, Martina; Pappa, Irene; Pirpamer, Lukas; Pudas, Sara; Pütz, Benno; Rajan, Kumar B; Ramasamy, Adaikalavan; Richards, Jennifer S; Risacher, Shannon L; Roiz-Santiañez, Roberto; Rommelse, Nanda; Rose, Emma J; Royle, Natalie A; Rundek, Tatjana; Sämann, Philipp G; Satizabal, Claudia L; Schmaal, Lianne; Schork, Andrew J; Shen, Li; Shin, Jean; Shumskaya, Elena; Smith, Albert V; Sprooten, Emma; Strike, Lachlan T; Teumer, Alexander; Thomson, Russell; Tordesillas-Gutierrez, Diana; Toro, Roberto; Trabzuni, Daniah; Vaidya, Dhananjay; Van der Grond, Jeroen; Van der Meer, Dennis; Van Donkelaar, Marjolein MJ; Van Eijk, Kristel R; Van Erp, Theo GM; Van Rooij, Daan; Walton, Esther; Westlye, Lars T; Whelan, Christopher D; Windham, Beverly G; Winkler, Anderson M; Woldehawariat, Girma; Wolf, Christiane; Wolfers, Thomas; Xu, Bing; Yanek, Lisa R; Yang, Jingyun; Zijdenbos, Alex; Zwiers, Marcel P; Agartz, Ingrid; Aggarwal, Neelum T; Almasy, Laura; Ames, David; Amouyel, Philippe; Andreassen, Ole A; Arepalli, Sampath; Assareh, Amelia A; Barral, Sandra; Bastin, Mark E; Becker, Diane M; Becker, James T; Bennett, David A; Blangero, John; van Bokhoven, Hans; Boomsma, Dorret I; Brodaty, Henry; Brouwer, Rachel M; Brunner, Han G; Buckner, Randy L; Buitelaar, Jan K; Bulayeva, Kazima B; Cahn, Wiepke; Calhoun, Vince D; Cannon, Dara M; Cavalleri, Gianpiero L; Chen, Christopher; Cheng, Ching-Yu; Cichon, Sven; Cookson, Mark R; Corvin, Aiden; Crespo-Facorro, Benedicto; Curran, Joanne E; Czisch, Michael; Dale, Anders M; Davies, Gareth E; De Geus, Eco JC; De Jager, Philip L; de Zubicaray, Greig I; Delanty, Norman; Depondt, Chantal; DeStefano, Anita L; Dillman, Allissa; Djurovic, Srdjan; Donohoe, Gary; Drevets, Wayne C; Duggirala, Ravi; Dyer, Thomas D; Erk, Susanne; Espeseth, Thomas; Evans, Denis A; Fedko, Iryna O; Fernández, Guillén; Ferrucci, Luigi; Fisher, Simon E; Fleischman, Debra A; Ford, Ian; Foroud, Tatiana M; Fox, Peter T; Francks, Clyde; Fukunaga, Masaki; Gibbs, J Raphael; Glahn, David C; Gollub, Randy L; Göring, Harald HH; Grabe, Hans J; Green, Robert C; Gruber, Oliver; Gudnason, Vilmundur; Guelfi, Sebastian; Hansell, Narelle K; Hardy, John; Hartman, Catharina A; Hashimoto, Ryota; Hegenscheid, Katrin; Heinz, Andreas; Le Hellard, Stephanie; Hernandez, Dena G; Heslenfeld, Dirk J; Ho, Beng-Choon; Hoekstra, Pieter J; Hoffmann, Wolfgang; Hofman, Albert; Holsboer, Florian; Homuth, Georg; Hosten, Norbert; Hottenga, Jouke-Jan; Hulshoff Pol, Hilleke E; Ikeda, Masashi; Ikram, M Kamran; Jack, Clifford R; Jenkinson, Mark; Johnson, Robert; Jönsson, Erik G; Jukema, J Wouter; Kahn, René S; Kanai, Ryota; Kloszewska, Iwona; Knopman, David S; Kochunov, Peter; Kwok, John B; Lawrie, Stephen M; Lemaître, Hervé; Liu, Xinmin; Longo, Dan L; Longstreth, WT; Lopez, Oscar L; Lovestone, Simon; Martinez, Oliver; Martinot, Jean-Luc; Mattay, Venkata S; McDonald, Colm; McIntosh, Andrew M; McMahon, Katie L; McMahon, Francis J; Mecocci, Patrizia; Melle, Ingrid; Meyer-Lindenberg, Andreas; Mohnke, Sebastian; Montgomery, Grant W; Morris, Derek W; Mosley, Thomas H; Mühleisen, Thomas W; Müller-Myhsok, Bertram; Nalls, Michael A; Nauck, Matthias; Nichols, Thomas E; Niessen, Wiro J; Nöthen, Markus M; Nyberg, Lars; Ohi, Kazutaka; Olvera, Rene L; Ophoff, Roel A; Pandolfo, Massimo; Paus, Tomas; Pausova, Zdenka; Penninx, Brenda WJH; Pike, G Bruce; Potkin, Steven G; Psaty, Bruce M; Reppermund, Simone; Rietschel, Marcella; Roffman, Joshua L; Romanczuk-Seiferth, Nina; Rotter, Jerome I; Ryten, Mina; Sacco, Ralph L; Sachdev, Perminder S; Saykin, Andrew J; Schmidt, Reinhold; Schofield, Peter R; Sigurdsson, Sigurdur; Simmons, Andy; Singleton, Andrew; Sisodiya, Sanjay M; Smith, Colin; Smoller, Jordan W; Soininen, Hilkka; Srikanth, Velandai; Steen, Vidar M; Stott, David J; Sussmann, Jessika E; Thalamuthu, Anbupalam; Tiemeier, Henning; Toga, Arthur W; Traynor, Bryan J; Troncoso, Juan; Turner, Jessica A; Tzourio, Christophe; Uitterlinden, Andre G; Valdés Hernández, Maria C; Van der Brug, Marcel; Van der Lugt, Aad; Van der Wee, Nic JA; Van Duijn, Cornelia M; Van Haren, Neeltje EM; Van 't Ent, Dennis; Van Tol, Marie-Jose; Vardarajan, Badri N; Veltman, Dick J; Vernooij, Meike W; Völzke, Henry; Walter, Henrik; Wardlaw, Joanna M; Wassink, Thomas H; Weale, Michael E; Weinberger, Daniel R; Weiner, Michael W; Wen, Wei; Westman, Eric; White, Tonya; Wong, Tien Y; Wright, Clinton B; Zielke, H Ronald; Zonderman, Alan B; Deary, Ian J; DeCarli, Charles; Schmidt, Helena; Martin, Nicholas G; De Craen, Anton JM; Wright, Margaret J; Launer, Lenore J; Schumann, Gunter; Fornage, Myriam; Franke, Barbara; Debette, Stéphanie; Medland, Sarah E; Ikram, M Arfan; Thompson, Paul M

    2016-01-01

    Intracranial volume reflects the maximally attained brain size during development, and remains stable with loss of tissue in late life. It is highly heritable, but the underlying genes remain largely undetermined. In a genome-wide association study of 32,438 adults, we discovered five novel loci for intracranial volume and confirmed two known signals. Four of the loci are also associated with adult human stature, but these remained associated with intracranial volume after adjusting for height. We found a high genetic correlation with child head circumference (ρgenetic=0.748), which indicated a similar genetic background and allowed for the identification of four additional loci through meta-analysis (Ncombined = 37,345). Variants for intracranial volume were also related to childhood and adult cognitive function, Parkinson’s disease, and enriched near genes involved in growth pathways including PI3K–AKT signaling. These findings identify biological underpinnings of intracranial volume and provide genetic support for theories on brain reserve and brain overgrowth. PMID:27694991

  3. Endovascular strategy for unruptured cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mangiafico, S., E-mail: mangiax@libero.it [Interventional Neuroradiology Unit, Careggi University Hospital, Florence (Italy); Guarnieri, G., E-mail: gianluigiguarnieri@hotmail.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy); Consoli, A., E-mail: onemed21@gmail.com [Interventional Neuroradiology Unit, Careggi University Hospital, Florence (Italy); Ambrosanio, G., E-mail: gambros@libero.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy); Muto, M., E-mail: mutomar@tiscali.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy)

    2013-10-01

    The treatment of unruptured intracranial aneurysms (UIAs) remains complex and not clearly defined. While for ruptured intracranial aneurysms the management and the treatment option (surgery or endovascular treatment) are well defined by several trials, for asymptomatic UIAs the best management is still currently uncertain. The rationale to treat an UIA is to prevent the rupture and its consequent SAH and all complications derived from hemorrhage or reduce/eliminate neurological palsy. Although this statement is correct, the indication to treat an UIA should be based on a correct balance between the natural history of UIA and treatment risk. Patient's clinical history, aneurysm characteristics, and strategy management influence the natural history of UIAs and treatment outcomes. In the last 10 years and more, two important large multicenter studies were performed in order to analysis of all these factors and to evaluate the best treatment option for UIAs. The aim of this paper is to try to synthesize the possible indications to the endovascular treatment (EVT), when and how to treat an UIA.

  4. 3D angiography in the evaluation of intracranial aneurysms before and after treatment. Initial experience; L'angiografia 3D nella valutazione pre e post-trattamento degli aneurismi intracranici. Esperienza preliminare

    Energy Technology Data Exchange (ETDEWEB)

    Lauriola, Walter; Nardella, Michele; Strizzi, Vincenzo; Florio, Francesco [Casa Sollievo della Sofferenza, IRCCS San Giovanni Rotondo (Italy). Radiologia Interventistica; Cali, Alessandro; D' Angelo, Vincenzo [Casa Sollievo della Sofferenza, IRCCS San Giovanni Rotondo (Italy). Divisione di Neurochirugia

    2005-02-01

    Purpose: The aim of the study is to evaluate the advantages of 3D angiography as compared to 2D angiography in assessing intracranial aneurysms before and after treatment and, in particular, in selecting and planning the correct treatment. Materials and methods: Thirty intracranial aneurysms were retrospectively reviewed before and after treatment. The study population consisted of 12 men and 18 women (age range: 35-77 years; mean age: 58 years). Eighteen aneurysms were treated surgically, 10 endovascularly and 2 with combined treatment. The 2D and 3D finding before and after the treatment were compared , and the pre-treatment angiographic images were compared with surgical findings. The following parameters were assessed and compared: aneurysmal sac and neck size, vascular involvement and evaluation of post-treatment residual mass. Results: On the 2D DSA images, visualisation of the sac and neck was optimal in 45% and 15% of cases, adequate in 10% and 35% of cases and inadequate in 5% and 50% of cases, respectively. On the 3D DSA images, visualisation of the sac and neck was optimal in 100% of cases. Three-dimensional DSA was able to detect 8 aneurysms with vessel involvement in all cases (100%). Of these, four (50%) went undetected on 2D DSA; in two cases, two-dimensional DSA erroneously detected the presence of vascular involvement (false positive). Three-dimensional angiography proved superior to 2D angiography in the evaluation of the residual aneurysms treated with clipping. Finally, 3D DSA was able to reduce the number of the radiographic projections, the quantity of contrast medium, the time and associated risks necessary for a precise evaluation of the aneurysm. Conclusions: In our first experience, 3D DSA proved useful in reducing the risks and diagnostic time as well as in selecting and planning the treatment. Moreover, it improved the operating conditions of both surgical and endovascular treatment. Technological advances in this field will enable the

  5. Preoperative Prediction of the Necessity for Anterior Clinoidectomy During Microsurgical Clipping of Ruptured Posterior Communicating Artery Aneurysms.

    Science.gov (United States)

    Kamide, Tomoya; Burkhardt, Jan-Karl; Tabani, Halima; Safaee, Michael M; Lawton, Michael T

    2018-01-01

    Although most posterior communicating artery (PCoA) aneurysms can be clipped easily with excellent results, some require anterior clinoidectomy for safe and complete clipping. To review our microsurgical series of ruptured PCoA aneurysms and identify the preoperative predictors for anterior clinoidectomy during microsurgical clipping for PCoA aneurysms. Results from microsurgical clipping of 104 patients with ruptured PCoA aneurysms were reviewed retrospectively. Distances and angles were obtained from computed tomographic angiography and compared between the anterior and nonanterior clinoidectomy groups. Anterior clinoidectomy was required in 19 of the 104 cases (18%). None developed surgical complications due to anterior clinoid process (ACP) resection, including postoperative visual deficit. Univariate and multivariate analyses revealed that the distances from the ACP tip to the aneurysmal proximal neck and from the ACP line to the aneurysmal proximal neck were statistically significant predictive factors for the need of anterior clinoidectomy. Based on a receiver operating characteristic analysis, the distances from the ACP tip to the aneurysmal proximal neck PCoA aneurysm surgery, the distances from the ACP tip to the aneurysmal proximal neck and from the ACP line to the aneurysmal proximal neck were both found to be useful predictors of whether anterior clinoidectomy was required. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Development of an artifact-free aneurysm clip

    Directory of Open Access Journals (Sweden)

    Brack Alexander

    2016-09-01

    Full Text Available For the treatment of intracranial aneurysms with aneurysm clips, usually a follow-up inspection in MRI is required. To avoid any artifacts, which can make a proper diagnosis difficult, a new approach for the manufacturing of an aneurysm clip entirely made from fiber-reinforced plastics has been developed. In this paper the concept for the design of the clip, the development of a new manufacturing technology for the fiber-reinforced components as well as first results from the examination of the components in phantom MRI testing is shown.

  7. Predicting Factors of Chronic Subdural Hematoma Following Surgical Clipping in Unruptured and Ruptured Intracranial Aneurysm.

    Science.gov (United States)

    Kwon, Min-Yong; Kim, Chang-Hyun; Lee, Chang-Young

    2016-09-01

    The aim of this study is to analyze the differences in the incidence, predicting factors, and clinical course of chronic subdural hematoma (CSDH) following surgical clipping between unruptured (UIA) and ruptured intracranial aneurysm (RIA). We conducted a retrospective analysis of 752 patients (UIA : 368 and RIA : 384) who underwent surgical clipping during 8 years. The incidence and predicting factors of CSDH development in the UIA and RIA were compared according to medical records and radiological data. The incidence of postoperative CSDH was higher in the UIA (10.9%) than in the RIA (3.1%) (p=0.000). In multivariate analysis, a high Hounsfield (HF) unit (blood clots) for subdural fluid collection (SFC), persistence of SFC ≥5 mm and male sex in the UIA and A high HF unit for SFC and SFC ≥5 mm without progression to hydrocephalus in the RIA were identified as the independent predicting factors for CSDH development (psubdural space and persistence of SFC ≥5 mm were predicting factors in both UIA and RIA. However, progression to hydrocephalus may have in part contributed to low CSDH development in the RIA. We suggest that cleaning of blood clots in the subdural space and efforts to minimize SFC ≥5 mm at the end of surgery is helpful to prevent CSDH following aneurysmal clipping.

  8. The role of inflammation in cerebral aneurysms

    Directory of Open Access Journals (Sweden)

    Ali H Turkmani

    2015-06-01

    Full Text Available The natural history of unruptured intracranial aneurysms (IAs is poorly understood. At present, risk factors for aneurysm rupture are limited to demographics and rudimentary anatomic features of the aneurysm. The first sign of aneurysm destabilization and rupture may be subarachnoid hemorrhage, a potentially devastating brain injury with high morbidity and mortality. An emerging body of literature suggests a complex inflammatory cascade likely promotes aneurysm wall remodeling and progressive ballooning of the arterial wall, ultimately terminating in aneurysm rupture. These events likely begin with hemodynamic, flow-related endothelial injury; the injured endothelium stimulates inflammation, including the recruitment and transmigration of inflammatory cells, particularly macrophages. Various proteases are secreted by the inflammatory infiltrate, resulting in degradation of the extracellular matrix and the structural changes unique to IAs. Detailed understanding of these inflammatory processes may result in (1 early identification of patients at high risk for aneurysm rupture, perhaps via arterial wall imaging, and (2 targeted, noninvasive therapies to treat or even prevent cerebral aneurysms.

  9. Hemodynamics Modeling and Simulation of Anterior Communicating Artery Aneurysms

    Directory of Open Access Journals (Sweden)

    Jianjun Li

    2014-07-01

    Full Text Available It is a general agreement that hemodynamics plays very important role in the initiation, growth, and rupture of cerebral aneurysms and hemodynamics in the anterior communicating artery aneurysms is considered the most complex in all cerebral aneurysms and it is difficult to find some reasonable relationship between the hemodynamics parameters and the rupture risk. In this paper, the 3D geometries of four anterior communicating artery aneurysms were generated from the CTA data and the computational models with bilateral feeding arteries for the four aneurysms were constructed. The blood flow was simulated by computational fluid dynamics software and the hemodynamics parameters such as velocity, wall shear stress, and oscillatory shear index were calculated. The following results were observed: one of the four models only needs the left feeding artery; the max normalized wall shear stress locates at the aneurysmal neck of the largest aneurysm; the max oscillatory shear index locates at the aneurysmal sac of the largest aneurysm. The conclusion was drawn that the anterior communicating artery aneurysm has higher rupture risk from the hemodynamics viewpoint if the max wall shear stress locates at the neck and the max oscillatory shear index locates at the dome.

  10. Use of thromboelastography to tailor dual-antiplatelet therapy in patients undergoing treatment of intracranial aneurysms with the Pipeline embolization device.

    Science.gov (United States)

    McTaggart, Ryan A; Choudhri, Omar A; Marcellus, Mary L; Brennan, Tom; Steinberg, Gary K; Dodd, Robert L; Do, Huy M; Marks, Michael P

    2015-06-01

    Platelet function testing is controversial and not well studied in patients with neurovascular disease. To evaluate the performance of thromboelastography (TEG) as a platelet function test in neurovascular patients treated with the Pipeline embolization device (PED). A prospective protocol was instituted for platelet function testing in patients undergoing repair of intracranial aneurysms with the PED. All patients received dual antiplatelet therapy (DAT) and their response to both P2Y12 inhibitors and aspirin was quantified with TEG. Each patient's DAT induction strategy was tailored based on the percentage ADP-induced and percentage arachidonic acid-induced platelet inhibition reported by TEG. Data collected included clinical presentation, aneurysm characteristics, treatment details, and periprocedural events. Patients were followed up clinically and/or angiographically at 30 days, 6 months, and 1 year. Thirty-four PED procedures were performed on 31 patients. TEG results altered the DAT strategy in 35% of patients. Technical success with the Pipeline placement was 100%. Two patients had minor strokes and five had transient ischemic attacks (TIAs). There have been no hemorrhagic complications. No patient had permanent neurologic deficits. Six of eight (75%) of patients with thromboembolic/TIA events were ADP-induced hyporesponders by TEG. Our 6- and 12-month angiographic occlusion rates were 78.9% and 89.5%, respectively. The 19 major branches covered by the PED that were assessed by follow-up imaging have all remained patent. Platelet function testing with TEG altered our DAT induction strategy in a significant number of cases. No hemorrhagic or disabling thromboembolic complications were seen in this series. Future studies should compare methods of platelet function testing and, possibly, no platelet function testing in neurovascular patients undergoing flow diversion and/or stent-assisted treatment of intracranial aneurysms. Published by the BMJ

  11. Inflammation and intracranial aneurysms: mechanisms of initiation, growth, and rupture

    Directory of Open Access Journals (Sweden)

    Peter S Amenta

    2015-06-01

    Full Text Available Outcomes following aneurysmal subarachnoid hemorrhage remain poor in many patients, despite advances in microsurgical and endovascular management. Consequently, considerable effort has been placed in determining the mechanisms of aneurysm formation, growth, and rupture. Various environmental and genetic factors are implicated as key components in the aneurysm pathogenesis. Currently, sufficient evidence exists to incriminate the inflammatory response as the common pathway leading to aneurysm generation and rupture. Central to this model is the interaction between the vessel wall and inflammatory cells. Dysfunction of the endothelium and vascular smooth muscle cells (VSMCs promotes a chronic pathological inflammatory response that progressively weakens the vessel wall. We review the literature pertaining to the cellular and chemical mechanisms of inflammation that contribute to aneurysm development. Hemodynamic stress and alterations in blood flow are discussed regarding their role in promoting chronic inflammation. Endothelial cell and VSMC dysfunction are examined concerning vascular remodeling. The contribution of inflammatory cytokines, especially tumor necrosis factor-α is illustrated. Inflammatory cell infiltration, particularly macrophage-mediated deterioration of vascular integrity, is reviewed. We discuss the inflammation as a means to determine aneurysms at greatest risk of rupture. Finally, future therapeutic implications of pharmacologic modulation of the inflammation are discussed.

  12. Diagnostic value of 3D time-of-flight magnetic resonance angiography for detecting intracranial aneurysm: a meta-analysis.

    Science.gov (United States)

    HaiFeng, Liu; YongSheng, Xu; YangQin, Xun; Yu, Dou; ShuaiWen, Wang; XingRu, Lu; JunQiang, Lei

    2017-11-01

    This meta-analysis is to comprehensively evaluate the diagnostic performance of three-dimensional time-of-flight magnetic resonance angiography (3D-TOF-MRA) for detecting intracranial aneurysm (IA). PubMed, Embase, Web of Science, and the Cochrane library were systematically searched for retrieving eligible studies. Study inclusion, data extraction, and risk of bias assessment were performed by two researchers independently. Pooled sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) were calculated to assess the diagnostic value. In addition, heterogeneity and subgroup analysis were carried out. In total, 18 studies comprising 3463 patients were selected. The results of 3D-TOF-MRA for diagnosing IA were SEN 0.89 (95% CI 0.82-0.94), SPE 0.94 (0.86-0.97), PLR 13.79 (5.92-32.12), NLR 0.11 (0.07-0.19), DOR 121.90 (38.81-382.94), and AUC 0.96 (0.94-0.98), respectively. In the subgroup analysis, studies without subarachnoid hemorrhage (SAH) tend to perform statistical significantly better (P 3D-TOF-MRA had better SEN in aneurysms > 3 mm than the aneurysms ≤ 3 mm in diameter: 0.89 (0.87-0.92) vs. 0.78 (0.71-0.84) with P 3D-TOF-MRA has an excellent diagnostic performance for the overall assessment of IA and may serve as an alternative for further patient management with IA.

  13. The Role of Computational Fluid Dynamics in the Management of Unruptured Intracranial Aneurysms: A Clinicians' View

    Directory of Open Access Journals (Sweden)

    Pankaj K. Singh

    2009-01-01

    Full Text Available Objective. The importance of hemodynamics in the etiopathogenesis of intracranial aneurysms (IAs is widely accepted. Computational fluid dynamics (CFD is being used increasingly for hemodynamic predictions. However, alogn with the continuing development and validation of these tools, it is imperative to collect the opinion of the clinicians. Methods. A workshop on CFD was conducted during the European Society of Minimally Invasive Neurological Therapy (ESMINT Teaching Course, Lisbon, Portugal. 36 delegates, mostly clinicians, performed supervised CFD analysis for an IA, using the @neuFuse software developed within the European project @neurIST. Feedback on the workshop was collected and analyzed. The performance was assessed on a scale of 1 to 4 and, compared with experts' performance. Results. Current dilemmas in the management of unruptured IAs remained the most important motivating factor to attend the workshop and majority of participants showed interest in participating in a multicentric trial. The participants achieved an average score of 2.52 (range 0–4 which was 63% (range 0–100% of an expert user. Conclusions. Although participants showed a manifest interest in CFD, there was a clear lack of awareness concerning the role of hemodynamics in the etiopathogenesis of IAs and the use of CFD in this context. More efforts therefore are required to enhance understanding of the clinicians in the subject.

  14. Social outcome related to cognitive performance and computed tomographic findings after surgery for a ruptured intracranial aneurysm.

    Science.gov (United States)

    Vilkki, J; Holst, P; Ohman, J; Servo, A; Heiskanen, O

    1990-04-01

    A series of 83 patients was examined with a battery of cognitive tests, a clinical interview, and computed tomography 1 year after surgery for a ruptured intracranial aneurysm. Disability on the Glasgow Outcome Scale (33%), failure to return to work (25%), impaired social relations (25%), and subjective or clinical mental impairment (56%) were found to be related to each other and to poor performance on cognitive tests, especially to verbal impairments in patients with left lateral infarctions and to memory deficits and cognitive inflexibility in patients with frontal medial infarctions. Furthermore, cognitive deficits and poor outcome were associated with diffuse brain damage. Depression and anxiety were unrelated to test performances, but were frequently reported by patients with right lateral infarctions.

  15. Diffusion-Weighted Imaging-Detected Ischemic Lesions following Endovascular Treatment of Cerebral Aneurysms: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Bond, K M; Brinjikji, W; Murad, M H; Kallmes, D F; Cloft, H J; Lanzino, G

    2017-02-01

    Endovascular treatment of intracranial aneurysms is associated with the risk of thromboembolic ischemic complications. Many of these events are asymptomatic and identified only on diffusion-weighted imaging. We performed a systematic review and meta-analysis to study the incidence of DWI positive for thromboembolic events following endovascular treatment of intracranial aneurysms. A comprehensive literature search identified studies published between 2000 and April 2016 that reported postprocedural DWI findings in patients undergoing endovascular treatment of intracranial aneurysms. The primary outcome was the incidence of DWI positive for thromboembolic events. We examined outcomes by treatment type, sex, and aneurysm characteristics. Meta-analyses were performed by using a random-effects model. Twenty-two studies with 2148 patients and 2268 aneurysms were included. The overall incidence of DWI positive for thromboembolic events following endovascular treatment was 49% (95% CI, 42%-56%). Treatment with flow diversion trended toward a higher rate of DWI positive for lesions than coiling alone (67%; 95% CI, 46%-85%; versus 45%; 95% CI, 33%-56%; P = .07). There was no difference between patients treated with coiling alone and those treated with balloon-assisted (44%; 95% CI, 29%-60%; P = .99) or stent-assisted (43%; 95% CI, 24%-63%; P = .89) coiling. Sex, aneurysm rupture status, location, and size were not associated with the rate of DWI positive for lesions. One in 2 patients may have infarcts on DWI following endovascular treatment of intracranial aneurysms. There is a trend toward a higher incidence of DWI-positive lesions following treatment with flow diversion compared with coiling. Patient demographics and aneurysm characteristics were not associated with DWI-positive thromboembolic events. © 2017 by American Journal of Neuroradiology.

  16. Hypertrophic remodeling and increased arterial stiffness in patients with intracranial aneurysms.

    Science.gov (United States)

    Maltete, David; Bellien, Jeremy; Cabrejo, Lucie; Iacob, Michele; Proust, François; Mihout, Bruno; Thuillez, Christian; Guegan-Massardier, Evelyne; Joannides, Robinson

    2010-08-01

    Because an underlying arteriopathy might contribute to the development of intracranial aneurysms (IAs), we assessed the elastic properties of proximal conduit arteries in patients with IA. In 27 patients with previous ruptured IA and 27 control subjects matched for age, gender and BMI, we determined arterial pressure, internal diameter, intima-media thickness (IMT), circumferential wall stress (CWS) and elastic modulus (wall stiffness) in common carotid arteries using applanation tonometry and echotracking. Moreover, carotid augmentation index (AIx, arterial wave reflections) and carotid-to-femoral pulse wave velocity (PWV, aortic stiffness) were assessed. Compared with controls, patients with IA exhibited higher brachial and carotid systolic and diastolic blood pressures, with similar brachial but higher carotid artery pulse pressure (35 + or - 6mm Hg vs. 41 + or - 8mm Hg, P=0.014). Moreover, patients have higher PWV (7.8 + or - 1.2ms(-1) vs. 8.3 + or - 1.1ms(-1), P=0.048) and AIx (15.8 + or - 10.8% vs. 21.1 + or - 8.5%, PIA display a particular carotid artery phenotype with an exaggerated hypertrophic remodeling and altered elastic properties. Thus, a systemic arteriopathy might contribute, together with the arterial wall fatiguing effect of the increased pulsatile stress, to the pathogenesis of IA. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  17. Surgical treatment of intracranial aneurysms: six-year experience in Belo Horizonte, MG, Brazil Tratamento cirúrgico dos aneurismas intracranianos: experiência de seis anos em Belo Horizonte, MG, Brasil

    Directory of Open Access Journals (Sweden)

    Leodante Batista da Costa Jr

    2004-06-01

    Full Text Available Spontaneous subarachnoid hemorrhage accounts for 5 to 10 % of all strokes, with a worldwide incidence of 10.5 / 100000 person/year, varying in individual reports from 1.1 to 96 /100000 person/year. Angiographic and autopsy studies suggest that between 0.5% and 5% of the population have intracranial aneurysms. Approximately 30000 people suffer aneurysmal subarachnoid hemorrhage in the United States each year, and 60% die or are left permanently disabled. We report our experience in the surgical treatment of intracranial aneurysms in a six year period, in Belo Horizonte, Minas Gerais, Brazil. We reviewed the hospital files, surgical and out-patient notes of all patients operated on for the treatment of intracranial aneurysms from January 1997 to January 2003. Four hundred and seventy-seven patients were submitted to 525 craniotomies for treatment of 630 intracranial aneurysms. The majority of patients were female (72.1% in the fourth or fifth decade of life. Anterior circulation aneurysms were more common (94.4%. The most common location for the aneurysm was the middle cerebral artery bifurcation. The patients were followed by a period from 1 month to 5 years. The outcome was measured by the Glasgow Outcome Scale (GOS. At discharge, 62.1% of the patients were classified as GOS 5, 13.9% as GOS 4, 8.7% as GOS 3, 1.7% as GOS 2 and 14.8% as GOS 1.A hemorragia subaracnóidea espontânea é responsável por cerca de 5 a 10% de todos os acidentes vasculares cerebrais, com uma incidência mundial de 10,5 / 100000 pessoas/ano, variando em estudos individuais de 1,1 a 96 / 100000 pessoas / ano, de acordo com diferenças étnicas e geográficas. Estudos angiográficos e de necropsia sugerem que a presença de aneurismas intracranianos ocorre em 0,5-5% da população mundial. De acordo com estatísticas norte-americanas, ocorrem cerca de 30000 rupturas de aneurisma cerebral por ano naquele país, com conseqüências desastrosas para grande parte dos pacientes

  18. Dissecting aneurysm of the cervical internal carotid artery

    International Nuclear Information System (INIS)

    Itoh, Yoshihiro; Itoyama, Youichi; Fukumura, Akinobu; Matsukado, Yasuhiko; Kodama, Takafumi.

    1987-01-01

    On lifting a heavy case, a 51-year-old male experienced a sudden onset of headache with giddiness and clouded vision. A week later, vertigo and right hand numbness were added to his symptoms. The next day anisocoria (right > left) and dilation of the left retinal veins were noted. Cranial computed tomography (CT) scan appeared normal and there were no other remarkable neurological findings. The patient was treated conservatively for cerebral infarction, however, the headache worsened and diplopia occurred. Neurological examination on admission revealed nothing unusual except for left Horner's syndrome. Physical examination showed a palpable sausage-like painless tumor on the left side of the neck. Angiography showed a narrowing of the internal carotid artery in the cervical region with a small dissecting aneurysm at the C3 level. Cervical CT scan at the upper C3 level showed a low density lunar defect in the high density section of the enlarged left internal carotid artery. The patient was operated on by superficial temporal artery-middle cerebral artery anastomosis to increase the intracranial blood flow. Postoperatively the symptoms were quickly relieved. Angiography 1 month later showed less narrowing of the carotid artery, though the dissecting aneurysm still remained. Postoperative cervical CT scan showed the left internal carotid artery to be of normal size. The patient returned to his work in normal condition 2 months later. It is emphasized that cervical CT scan may be useful in the diagnosis of this unusual type of cervical dissecting aneurysm. (author)

  19. Real-time surgery simulation of intracranial aneurysm clipping with patient-specific geometries and haptic feedback

    Science.gov (United States)

    Fenz, Wolfgang; Dirnberger, Johannes

    2015-03-01

    Providing suitable training for aspiring neurosurgeons is becoming more and more problematic. The increasing popularity of the endovascular treatment of intracranial aneurysms leads to a lack of simple surgical situations for clipping operations, leaving mainly the complex cases, which present even experienced surgeons with a challenge. To alleviate this situation, we have developed a training simulator with haptic interaction allowing trainees to practice virtual clipping surgeries on real patient-specific vessel geometries. By using specialized finite element (FEM) algorithms (fast finite element method, matrix condensation) combined with GPU acceleration, we can achieve the necessary frame rate for smooth real-time interaction with the detailed models needed for a realistic simulation of the vessel wall deformation caused by the clamping with surgical clips. Vessel wall geometries for typical training scenarios were obtained from 3D-reconstructed medical image data, while for the instruments (clipping forceps, various types of clips, suction tubes) we use models provided by manufacturer Aesculap AG. Collisions between vessel and instruments have to be continuously detected and transformed into corresponding boundary conditions and feedback forces, calculated using a contact plane method. After a training, the achieved result can be assessed based on various criteria, including a simulation of the residual blood flow into the aneurysm. Rigid models of the surgical access and surrounding brain tissue, plus coupling a real forceps to the haptic input device further increase the realism of the simulation.

  20. Intracranial Vascular Disease Evaluation With Combined Vessel Wall Imaging And Patient Specific Hemodynamics

    Science.gov (United States)

    Samson, Kurt; Mossa-Basha, Mahmud; Yuan, Chun; Canton, Maria De Gador; Aliseda, Alberto

    2017-11-01

    Intracranial vascular pathologies are evaluated with angiography, conventional digital subtraction angiography or non-invasive (MRI, CT). Current techniques present limitations on the resolution with which the vessel wall characteristics can be measured, presenting a major challenge to differential diagnostic of cerebral vasculopathies. A new combined approach is presented that incorporates patient-specific image-based CFD models with intracranial vessel-wall MRI (VWMRI). Comparisons of the VWMRI measurements, evaluated for the presence of wall enhancement and thin-walled regions, against CFD metrics such as wall shear stress (WSS), and oscillatory shear index (OSI) are used to understand how the new imaging technique developed can predict the influence of hemodynamics on the deterioration of the aneurysmal wall, leading to rupture. Additionally, histology of each resected aneurysm, evaluated for inflammatory infiltration and wall thickness features, is used to validate the analysis from VWMRI and CFD. This data presents a solid foundation on which to build a new framework for combined VWMRI-CFD to predict unstable wall changes in unruptured intracranial aneurysms, and support clinical monitoring and intervention decisions.

  1. Postprocedural Monitoring of Cerebral Aneurysms

    International Nuclear Information System (INIS)

    Kaehaerae, V.

    2006-01-01

    The treatment of intracranial aneurysms has been revolutionized since the introduction of electrolytically detachable platinum coils in 1991. Since this basic innovation, many refinements of the embolic materials and techniques have emerged. Today, in Europe, half of all aneurysms are treated endoarterially and this share is growing. The reassuring results of the International Subarachnoid Aneurysm Trial (ISAT) have changed the treatment strategy from neurosurgical clipping to embolization. However, the role of these alternative modes of treatment varies between institutions and countries. An angiographic follow-up pattern after endovascular treatment has remained largely undefined and in the same way there has been much diversity in applying alternative imaging modalities. Although some institutions continue to perform intervalled digital subtraction angiography, magnetic resonance angiography has assumed an increasing role. A vast majority of patients with embolized aneurysms are eligible to be monitored solely by non-contrast three-dimensional time-of-flight technique

  2. Characterizing saccular aortic arch aneurysms from the geometry-flow dynamics relationship.

    Science.gov (United States)

    Natsume, Kayoko; Shiiya, Norihiko; Takehara, Yasuo; Sugiyama, Masataka; Satoh, Hiroshi; Yamashita, Katsushi; Washiyama, Naoki

    2017-06-01

    Low wall shear stress (WSS) has been reported to be associated with accelerated atherosclerosis, aneurysm growth, or rupture. We evaluated the geometry of aortic arch aneurysms and their relationship with WSS by using the 4-dimensional flow magnetic resonance imaging to better characterize the saccular aneurysms. We analyzed the geometry in 100 patients using multiplanar reconstruction of computed tomography. We evaluated WSS and vortex flow using 4-dimensional flow magnetic resonance imaging in 16 of them, which were compared with 8 age-matched control subjects and eight healthy young volunteers. Eighty-two patients had a saccular aneurysm, and 18 had a fusiform aneurysm. External diameter/aneurysm length ratio and sac depth/neck width ratio of the fusiform aneurysms were constant at 0.76 ± 0.18 and 0.23 ± 0.09, whereas those of saccular aneurysms, especially those involving the outer curvature, were higher and more variable. Vortex flow was always present in the aneurysms, resulting in low WSS. When the sac depth/neck width ratio was less than 0.8, peak WSS correlated inversely with luminal diameter even in the saccular aneurysms. When this ratio exceeded 0.8, which was the case only with the saccular aneurysms, such correlation no longer existed and WSS was invariably low. Fusiform aneurysms elongate as they dilate, and WSS is lower as the diameter is larger. Saccular aneurysms dilate without proportionate elongation, and they, especially those occupying the inner curvature, have higher and variable sac depth/neck width ratio. When this ratio exceeds 0.8, WSS is low regardless of diameter, which may explain their malignant clinical behavior. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  3. A proposal for standardizing computed tomography reports on abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Torlai, Fabiola Goda; Meirelles, Gustavo S. Portes; Miranda Junior, Fausto; Fonseca, Jose Honorio A.P. da; Ajzen, Sergio; D'Ippolito, Giuseppe

    2006-01-01

    Objective: to propose a model to standardize computed tomography reports on abdominal aortic aneurysms. Materials and methods: interviews were carried out with members of the Vascular Surgery Division of our institution, in the period between April and October 2004, aiming at developing a standardized model of computed tomography reports on abdominal aortic aneurysms. Based on this model, a questionnaire was elaborated and sent to other nine surgeons, all of them experienced in the field of abdominal aortic surgery. The questionnaires response rate was 55.5% (5/9). Results: the most frequently mentioned parameters of interest for evaluation of abdominal aortic aneurysms were: maximum diameter of proximal aortic neck, proximal aortic neck length to lower renal arteries, shape of proximal aortic neck, maximum diameter of the aneurysm and diameter of the common iliac arteries. These data allowed the development of a proposal for a model to standardize computed tomography reports. Conclusion: a model for standardized tomographic analysis of abdominal aortic aneurysms has met vascular surgeons' needs for following-up patients and planning their treatment. (author)

  4. Radiation Exposure in Endovascular Infra-Renal Aortic Aneurysm Repair and Factors that Influence It

    Directory of Open Access Journals (Sweden)

    Rui Machado

    Full Text Available Abstract Objective: The endovascular repair of aortic abdominal aneurysms exposes the patients and surgical team to ionizing radiation with risk of direct tissue damage and induction of gene mutation. This study aims to describe our standard of radiation exposure in endovascular aortic aneurysm repair and the factors that influence it. Methods: Retrospective analysis of a prospective database of patients with abdominal infra-renal aortic aneurysms submitted to endovascular repair. This study evaluated the radiation doses (dose area product (DAP, fluoroscopy durations and their relationships to the patients, aneurysms, and stent-graft characteristics. Results: This study included 127 patients with a mean age of 73 years. The mean DAP was 4.8 mGy.m2, and the fluoroscopy time was 21.8 minutes. Aortic bilateral iliac aneurysms, higher body mass index, aneurysms with diameters larger than 60 mm, necks with diameters larger than 28 mm, common iliac arteries with diameters larger than 20 mm, and neck angulations superior to 50 degrees were associated with an increased radiation dose. The number of anatomic risk factors present was associated with increased radiation exposure and fluoroscopy time, regardless of the anatomical risk factors. Conclusion: The radiation exposure during endovascular aortic aneurysm repair is significant (mean DAP 4.8 mGy.m2 with potential hazards to the surgical team and the patients. The anatomical characteristics of the aneurysm, patient characteristics, and the procedure's technical difficulty were all related to increased radiation exposure during endovascular aortic aneurysm repair procedures. Approximately 40% of radiation exposure can be explained by body mass index, neck angulation, aneurysm diameter, neck diameter, and aneurysm type.

  5. Clinical and angiographic outcomes after stent-assisted coiling of cerebral aneurysms with Enterprise and Neuroform stents: a comparative analysis of the literature.

    Science.gov (United States)

    King, Brent; Vaziri, Sasha; Singla, Amit; Fargen, Kyle M; Mocco, J

    2015-12-01

    The most widely used intracranial stents for stent-assisted coiling are Neuroform (NEU) and Enterprise stents (ENT). This study compares published outcomes between the ENT and NEU coil-assist systems and comments on the published safety and efficacy of stent-assisted coiling in general. A literature search was performed through PubMed for all published series of ENT or NEU stent-assisted coiling of cerebral aneurysms from 2004 to 2014. All studies including 10 or more published cases of stent-assisted coiling with ENT or NEU were included. 47 studies met the inclusion criteria, containing 4238 aneurysms in 4039 patients. 2111 aneurysms were treated with NEU and 2127 were treated with ENT. Mean follow-up was 14.1 months. Overall, thromboembolic events occurred in 6.4% of aneurysms, intracranial hemorrhage (ICH) in 2.6%, permanent morbidity in 3.9%, and mortality in 2.3%. Initial and final 100% angiographic occlusion was seen in 53% and 69% of patients, respectively. Deployment failures (pstent-assisted coiling devices to date, containing over 4200 aneurysms in more than 4000 patients. Comparative analyses demonstrate that both devices are reported to be safe and effective with comparable permanent morbidity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. Should indications for WEB aneurysm treatment be enlarged? Report of a series of 20 patients with aneurysms in "atypical" locations for WEB treatment.

    Science.gov (United States)

    Pierot, L; Biondi, A; Narata, A-P; Mihalea, C; Januel, A-C; Metaxas, G; Bibi, R; Caroff, J; Soize, S; Cognard, C; Spelle, L; Herbreteau, D

    2017-06-01

    Flow disruption with the WEB device is an innovative technique for the endovascular treatment of wide neck bifurcation aneurysms. Good clinical practice trials have shown high safety of this treatment with good efficacy. Technical developments (single layer devices and smaller microcatheters) facilitate the treatment, potentially leading to enlargement of indications. This series is collecting aneurysms in "atypical" locations for WEB treatment and analyzing safety and efficacy of this treatment. In each participating center, patients with aneurysms treated with WEB were prospectively included in a local database. Patients treated for aneurysms in "atypical" locations were extracted. Patient and aneurysm characteristics, intraoperative complications, and anatomical results at the end of the procedure and at last follow-up were collected and analyzed. Five French neurointerventional centers included 20 patients with 20 aneurysms in "atypical" locations for WEB treatment treated with WEB. Aneurysm locations were ICA carotid-ophthalmic in 9 aneurysms (45.0%), ICA posterior communicating in 4 (20.0%), Pericallosal artery in 5 (25.0%), and basilar artery between P1 and superior cerebellar artery in 2 (10.0%). There were no complications (thromboembolic or intraoperative rupture) in this series. At follow-up (mean: 7.4 months), adequate occlusion was obtained in 100.0% of aneurysms. This series confirms that it is possible to enlarge indications of WEB treatment to "atypical" locations with good safety and efficacy. These data have to be confirmed in large prospective series. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. Safety and efficacy of aneurysm treatment with WEB in the cumulative population of three prospective, multicenter series

    DEFF Research Database (Denmark)

    Pierot, Laurent; Moret, Jacques; Barreau, Xavier

    2018-01-01

    BACKGROUND: Flow disruption with the WEB is an innovative endovascular approach for treatment of wide-neck bifurcation aneurysms. Initial studies have shown a low complication rate with good efficacy. PURPOSE: To report clinical and anatomical results of the WEB treatment in the cumulative popula...

  8. Traumatic aneurysms of the pericallosal arteries

    International Nuclear Information System (INIS)

    Nakstad, P.; Nornes, H.; Hauge, H.N.

    1986-01-01

    Of a total of 912 operated intracranial aneurysms only three were classified as traumatic (0.3%). They were found in children after severe head trauma and were all located on the pericallosal artery or its branches and not a bifurcations. Shearing forces between the falx, the arteries and the brain at the time of injury are held responsible for the development of these aneurysms. Unlike these traumatic aneurysms, 29 ''spontaneous'' pericallosal aneurysms (3.2%) in adults were located at the bifurcations of the artery. As significantly fewer reports of traumatic aneurysms have been published during the last decade than before 1976, it is suggested that some might have been overlooked as a consequence of CT replacing cerebral angiography in the neuroradiological evaluation of severe head injury. This possibility should be kept in mind, especially when dealing with children after head injury and when CT scans indicate brain damage around the falx. The possibility of overlooking traumatic pericallosal aneurysms is described by other authors and discussed further in this paper. (orig.)

  9. Long-term follow-up of aneurysms treated electively with woven stent-assisted coiling.

    Science.gov (United States)

    Cheung, Nicholas K; Chiu, Albert Hy; Cheung, Andrew K; Wenderoth, Jason D

    2017-12-15

    Preliminary short-term results for stent-assisted coil embolization (SACE) using woven/braided stents have been promising. However, evidence supporting mid- to long-term efficacy and durability is lacking. To report the long-term results for the durability of elective intracranial aneurysms treated with woven stents. Between May 2012 and May 2015, 98 consecutive patients with 103 aneurysms underwent elective woven SACE across three Australian neurovascular centres. All patients had immediate, 6- and 18-month clinical and radiological follow-up. Radiological assessment was performed with modified Raymond-Roy occlusion scores based on angiography results, while clinical assessment was based on the modified Rankin Scale. Six-month follow-up was available in 100 aneurysms, and an 18-month follow-up in 97 aneurysms. Total occlusion rates of 82% were achieved at inception, 82% at 6 months, and 90% at 18 months. Satisfactory occlusion with small neck remnants was present in 17% at inception, 16% at 6 months, and 9% at 18 months. Good neurological outcomes were achieved in 95% at 18 months. Intraprocedural thromboembolic events were recorded in 3% and delayed events in 1% (all in patients taking clopidogrel). Aneurysm recurrence occurred in one patient (1%). Technical complications occurred in 5%. The total complication rate was 10%. Woven SACE is safe, efficacious, and durable at long-term 18-month follow-up, with very low recurrence and re-treatment rates. Preliminary results appear better than those for traditional laser-cut stents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Velocity profile and wall shear stress of saccular aneurysms at the anterior communicating artery.

    Science.gov (United States)

    Yamaguchi, Ryuhei; Ujiie, Hiroshi; Haida, Sayaka; Nakazawa, Nobuhiko; Hori, Tomokatsu

    2008-01-01

    It has recently been shown that the aspect ratio (dome/neck) of an aneurysm correlates well with intraaneurysmal blood flow. Aneurysms with an aspect ratio larger than 1.6 carry a higher risk of rupture. We examined the effect of aspect ratio (AR) on intra-aneurysmal flow using experimental models. Flow visualization with particle imaging velocimetry and measurement of wall shear stress using laser Doppler anemometry were performed on three different aneurysm models: AR 0.5, 1.0, and 2.0. Intraaneurysmal flow consists of inflow, circulation, and outflow. Rapid inflow impinged on the distal neck creating a stagnant point. Rapid flow and maximum wall shear stress were observed in the vicinity of the stagnant point. By changing the Reynold's number, the stagnant point moved. By increasing the AR of the aneurysm, vortices inside the aneurysm sac closed and very slow flow was observed, resulting in very low shear stress markedly at a Reynold's number of 250, compatible with the diastolic phase. In the aneurysm model AR 2.0, both rapid flow at the neck and vortices inside the aneurysm are sufficient to activate platelets, making a thrombus that may anchor on the dome where very slow flow takes place. Hemodynamics in aneurysms larger than AR 2.0 definitely contribute to thrombus formation.

  11. Giant aneurysm in 6 years old child - case report

    International Nuclear Information System (INIS)

    Sirakov, S.; Penkov, M.; Todorov, Y; Minkin, K.

    2014-01-01

    Intracranial saccular aneurysms rare in childhood is. Even among the reported series of childhood aneurysms, it is unusual to find their occurrence in children less than 7 years old. The pathogenesis of these lesions is also a matter of debate and speculations. The peak age of incidence of juvenile cerebral aneurysms appear to be 12 years, occurrence below the age of 7 being rarity. We show a case of 6 years old boy with giant aneurysm. found because of episodes of headache and vomiting. Discussion of pathogenesis for the rare pathology. After discussion of multidisciplinary team, of neuroradiologist and neurosurgeons was decided to be perform endovascular embolization, because of the better outcome for the patient. We performed endovascular treatment of the aneurysm with achieving total embolization. The patient recovery completely, and after 4 days went home. (authors) Key words: GIANT ANEURYSM. SACCULAR ANEURYSM. EMBOLIZATION. STENT ASSISTED COILING

  12. Management of aneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Etminan, N; Macdonald, R L

    2017-01-01

    Spontaneous subarachnoid hemorrhage (SAH) affects people with a mean age of 55 years. Although there are about 9/100 000 cases per year worldwide, the young age and high morbidity and mortality lead to loss of many years of productive life. Intracranial aneurysms account for 85% of cases. Despite this, the majority of survivors of aneurysmal SAH have cognitive deficits, mood disorders, fatigue, inability to return to work, and executive dysfunction and are often unable to return to their premorbid level of functioning. The main proven interventions to improve outcome are aneurysm repair in a timely fashion by endovascular coiling rather than neurosurgical clipping when feasible and administration of nimodipine. Management also probably is optimized by neurologic intensive care units and multidisciplinary teams. Improved diagnosis, early aneurysm repair, administration of nimodipine, and advanced neurointensive care support may be responsible for improvement in survival from SAH in the last few decades. © 2017 Elsevier B.V. All rights reserved.

  13. Blood Pressure and Intracranial Aneurysms in Autosomal Dominant Polycystic Kidney Disease

    Directory of Open Access Journals (Sweden)

    Mariusz Niemczyk

    2014-12-01

    Full Text Available Background/Aims: Autosomal dominant polycystic kidney disease (ADPKD is correlated with an increased frequency of both intracranial aneurysms (ICANs, and arterial hypertension (AH. The aim of our study was to search for the association between blood pressure (BP and ICANs in ADPKD patients. Methods: Sixty-eight adult, pre-dialysis phase ADPKD patients underwent both screening for ICANs with magnetic resonance angiography of the brain, and ambulatory blood pressure monitoring (ABPM. Results: ICANs were diagnosed in 10 patients (ICAN(+ group, while in 58 were not (ICAN(- group. The nighttime maximum diastolic blood pressure (DBP, maximum increase in DBP from measurement to measurement (positive delta of DBP at night, and the standard deviation of the daytime mean arterial pressure were significantly higher in ICAN(+ compared to ICAN(- patients. Additionally, in a subgroup of patients after 45 years-of-age, ICAN(+ patients had significantly higher maximum 24-hour and daytime systolic blood pressure, maximum 24-hour, daytime, nighttime DBP, maximum daytime and nighttime positive delta of DBP compared to ICAN(- cases. Conclusions: Development of ICANs in hypertensive ADPKD patients is accompanied with higher values of some BP parameters measured by ABPM. Hypertensive ADPKD patients with substantial fluctuations in BP assessed by ABPM, especially those after 45 years-of-age, should become candidates for screening for ICANs.

  14. Clinical and imaging features of intracranial arterial aneurysms in the pediatric population; Klinische und radiologische Merkmale des intrakraniellen arteriellen Aneurysmas bei Kindern und Jugendlichen

    Energy Technology Data Exchange (ETDEWEB)

    Abruzzo, Todd A. [Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States). Dept. of Radiology; Aeron, Gunjan; Jones, Blaise V.

    2013-07-15

    Intracranial arterial aneurysms (IAAs) are rare in children. Nevertheless, IAAs account for at least 10 % - 15 % of hemorrhagic strokes during the first two decades of life. Traditional vascular risk factors, which are common in the adult population, are generally absent in the pediatric population, engendering distinct modes of IAA pathogenesis. Classification of pediatric IAAs according to the pathogenetic mechanism shows eight distinct categories: idiopathic, traumatic, those due to excessive hemodynamic stress, vasculopathic, infectious, noninfectious inflammatory, oncotic, and familial. Pathogenetic mechanism is the best predictor of the clinical course of the disease, response to treatment, and long-term prognosis. The pathogenetic subtypes of pediatric IAA show characteristic and variably overlapping features. In most cases, IAAs manifesting during the first two decades of life are idiopathic. IAAs that are idiopathic, traumatic (second most common type), or due to excessive hemodynamic stresses (third most common type) account for more than 80 % of IAAs in the pediatric age group. Most of the remaining pediatric IAAs are the result of congenital cerebral aneurysmal arteriopathies or infection. Multiple IAAs are unusual in young children except in those with acquired (secondary to immune deficiency states) or congenital cerebral aneurysmal arteriopathies or infectious IAAs. (orig.)

  15. Association between NFKB1 -94 insertion/deletion ATTG polymorphism and risk of intracranial aneurysm.

    Science.gov (United States)

    Sima, Xiutian; Xu, Jianguo; Li, Jin; You, Chao

    2013-08-01

    Growing evidence indicates that vascular inflammation is a common phenomenon in the pathogenesis of intracranial aneurysms (IAs). Nuclear factor kappa B is a key molecule that is involved in the vascular inflammation of IA. We hypothesized that an insertion/deletion (ins/del) ATTG polymorphism located between two putative key promoter regulatory elements in the NFKB1 gene may be related to the risk of IA. We performed a case-control study, including 164 patients with IA and 525 healthy controls in a Chinese population using a polymerase chain reaction-polyacrylamide gel electrophoresis assay. A significantly decreased risk of IA was observed in the ATTG1/ATTG2 and ATTG2/ATTG2 genotypes compared with the ATTG1/ATTG1 genotype (ATTG1/ATTG2 vs. ATTG1/ATTG1: odds ratio [OR]=0.58, 95% confidence interval [95% CI]=0.39-0.87, p=0.007; ATTG2/ATTG2 vs. ATTG1/ATTG1: OR=0.12, 95% CI=0.06-0.23, p41, 95% CI=0.32-0.54, pIA.

  16. Late-onset Pompe disease with complicated intracranial aneurysm: a Chinese case report

    Directory of Open Access Journals (Sweden)

    Zhang B

    2016-03-01

    Full Text Available Bin Zhang,1,2,* Yuying Zhao,1,3,* Junling Liu,1,4 Ling Li,1 Jingli Shan,1 Dandan Zhao,1 Chuanzhu Yan1,3 1Laboratory of Neuromuscular Disorders and Department of Neurology, Qilu Hospital of Shandong University, Jinan, Shandong, 2Department of Neurology, Liaocheng People’s Hospital, Liaocheng, Shandong, 3Department of Neurology, Qilu Hospital of Shandong University, Key Laboratory for Experimental Teratology of the Ministry of Education, Brain Science Research Institute, Shandong University, Jinan, Shandong, 4Department of Neurology, Affiliated Hospital of Weifang Medical University, Weifang, Shandong, People’s Republic of China *These authors contributed equally to this work Abstract: Pompe disease is a rare autosomal recessive hereditary disease caused by genetic defects of acid maltase. This disease could be divided into two forms: infantile and late-onset, which mainly affect cardiac, respiratory, and skeletal muscle systems. Late-onset patients mainly show symptoms of skeletal muscle involvement, but recent reports have found that the central nervous system was also affected in some patients. Herein, we report a case of a female, adolescent-onset Pompe patient, who was diagnosed with complicated intracranial aneurysm in adulthood. Keywords: Pompe disease, glycogen storage disease II, acid maltase, acid alpha-glucosidase, cerebrovascular disorders

  17. Effects of Reynolds and Womersley Numbers on the Hemodynamics of Intracranial Aneurysms

    Science.gov (United States)

    Asgharzadeh, Hafez

    2016-01-01

    The effects of Reynolds and Womersley numbers on the hemodynamics of two simplified intracranial aneurysms (IAs), that is, sidewall and bifurcation IAs, and a patient-specific IA are investigated using computational fluid dynamics. For this purpose, we carried out three numerical experiments for each IA with various Reynolds (Re = 145.45 to 378.79) and Womersley (Wo = 7.4 to 9.96) numbers. Although the dominant flow feature, which is the vortex ring formation, is similar for all test cases here, the propagation of the vortex ring is controlled by both Re and Wo in both simplified IAs (bifurcation and sidewall) and the patient-specific IA. The location of the vortex ring in all tested IAs is shown to be proportional to Re/Wo2 which is in agreement with empirical formulations for the location of a vortex ring in a tank. In sidewall IAs, the oscillatory shear index is shown to increase with Wo and 1/Re because the vortex reached the distal wall later in the cycle (higher resident time). However, this trend was not observed in the bifurcation IA because the stresses were dominated by particle trapping structures, which were absent at low Re = 151.51 in contrast to higher Re = 378.79. PMID:27847544

  18. Hemodynamic response during aneurysm clipping surgery among experienced neurosurgeons.

    Science.gov (United States)

    Bunevicius, Adomas; Bilskiene, Diana; Macas, Andrius; Tamasauskas, Arimantas

    2016-02-01

    Neurosurgery is a challenging field associated with high levels of mental stress. The goal of this study was to investigate the hemodynamic response of experienced neurosurgeons during aneurysm clipping surgery and to evaluate whether neurosurgeons' hemodynamic responses are associated with patients' clinical statuses. Four vascular neurosurgeons (all male; mean age 51 ± 10 years; post-residency experience ≥7 years) were studied during 42 aneurysm clipping procedures. Blood pressure (BP) and heart rate (HR) were assessed at rest and during seven phases of surgery: before the skin incision, after craniotomy, after dural opening, after aneurysm neck dissection, after aneurysm clipping, after dural closure and after skin closure. HR and BP were significantly greater during surgery relative to the rest situation (p ≤ 0.03). There was a statistically significant increase in neurosurgeons' HR (F [6, 41] = 10.88, p neurosurgeon experience, the difference in BP as a function of aneurysm rupture was not significant (p > 0.08). Aneurysm location, intraoperative aneurysm rupture, admission WFNS score, admission Glasgow Coma Scale scores and Fisher grade were not associated with neurosurgeons' intraoperative HR and BP (all p > 0.07). Aneurysm clipping surgery is associated with significant hemodynamic system activation among experienced neurosurgeons. The greatest HR and BP were after aneurysm neck dissection and clipping. Aneurysm location and patient clinical status were not associated with intraoperative changes of neurosurgeons' HR and BP.

  19. Coma and Stroke Following Surgical Treatment of Unruptured Intracranial Aneurysm: An American College of Surgeons National Surgical Quality Improvement Program Study.

    Science.gov (United States)

    McCutcheon, Brandon A; Kerezoudis, Panagiotis; Porter, Amanda L; Rinaldo, Lorenzo; Murphy, Meghan; Maloney, Patrick; Shepherd, Daniel; Hirshman, Brian R; Carter, Bob S; Lanzino, Giuseppe; Bydon, Mohamad; Meyer, Fredric

    2016-07-01

    A large national surgical registry was used to establish national benchmarks and associated predictors of major neurologic complications (i.e., coma and stroke) after surgical clipping of unruptured intracranial aneurysms. The American College of Surgeons National Surgical Quality Improvement Program data set between 2007 and 2013 was used for this retrospective cohort analysis. Demographic, comorbidity, and operative characteristics associated with the development of a major neurologic complication (i.e., coma or stroke) were elucidated using a backward selection stepwise logistic regression analysis. This model was subsequently used to fit a predictive score for major neurologic complications. Inclusion criteria were met by 662 patients. Of these patients, 57 (8.61%) developed a major neurologic complication (i.e., coma or stroke) within the 30-day postoperative period. On multivariable analysis, operative time (log odds 0.004 per minute; 95% confidence interval [CI], 0.002-0.007), age (log odds 0.05 per year; 95% CI, 0.02-0.08), history of chronic obstructive pulmonary disease (log odds 1.26; 95% CI, 0.43-2.08), and diabetes (log odds 1.15; 95% CI, 0.38-1.91) were associated with an increased odds of major neurologic complications. When patients were categorized according to quartile of a predictive score generated from the multivariable analysis, rates of major neurologic complications were 1.8%, 4.3%, 6.7%, and 21.2%. Using a large, national multi-institutional cohort, this study established representative national benchmarks and a predictive scoring system for major neurologic complications following operative management of unruptured intracranial aneurysms. The model may assist with risk stratification and tailoring of decision making in surgical candidates. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Rerupture of intracranial aneurysms: a clinicoanatomic study

    NARCIS (Netherlands)

    Hijdra, A.; Vermeulen, M.; van Gijn, J.; van Crevel, H.

    1987-01-01

    In a series of 176 prospectively studied patients who survived for at least 24 hours after aneurysmal subarachnoid hemorrhage, 39 had at least one computerized tomography (CT)-proven rebleed within 4 weeks after the first rupture. There were peaks in the incidence of rebleeding at the end of the 2nd

  1. Recovery to Preinterventional Functioning, Return-to-Work, and Life Satisfaction After Treatment of Unruptured Aneurysms

    NARCIS (Netherlands)

    Backes, Daan; Rinkel, Gabriel J. E.; van der Schaaf, Irene C.; Bijvank, Jenny A. Nij; Verweij, Bon H.; Visser-Meily, Johanna M. A.; Post, Marcel W.; Algra, Ale; Vergouwen, Mervyn D. I.

    Background and Purpose-The eventual goal of preventive treatment of unruptured intracranial aneurysms is to increase the number of life years with high life satisfaction. Insight in the time with reduced functioning, working capacity, and life satisfaction after aneurysm treatment is pivotal to

  2. Recovery to Preinterventional Functioning, Return-to-Work, and Life Satisfaction After Treatment of Unruptured Aneurysms

    NARCIS (Netherlands)

    Backes, D.; Rinkel, G.J.; Van der Schaaf, I.C.; Bijvank, J.A.; Verweij, B.H.; Visser-Meily, J.M.A.; Post, Marcel W.M.; Algra, A.; Vergouwen, M.D.

    Background and Purpose—The eventual goal of preventive treatment of unruptured intracranial aneurysms is to increase the number of life years with high life satisfaction. Insight in the time with reduced functioning, working capacity, and life satisfaction after aneurysm treatment is pivotal to

  3. Aneurysmal sub-arachnoid haemorrhage in patients with Noonan syndrome: a report of two cases and review of neurovascular presentations in this syndrome

    International Nuclear Information System (INIS)

    Dineen, R.A.; Lenthall, R.K.

    2004-01-01

    To date, intracranial aneurysms have been reported in two patients with Noonan syndrome. We report two unrelated patients with Noonan syndrome who presented with sub-arachnoid haemorrhage secondary to intracranial aneurysms. These cases are discussed and other cerebrovascular abnormalities that have been described in association with Noonan syndrome are reviewed. Ultrastructural and genetic factors contributing to these associations are considered. (orig.)

  4. Aneurysmal sub-arachnoid haemorrhage in patients with Noonan syndrome: a report of two cases and review of neurovascular presentations in this syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Dineen, R.A.; Lenthall, R.K. [Department of Radiology, University Hospital, Queen' s Medical Centre, NG7 2UH, Nottingham (United Kingdom)

    2004-04-01

    To date, intracranial aneurysms have been reported in two patients with Noonan syndrome. We report two unrelated patients with Noonan syndrome who presented with sub-arachnoid haemorrhage secondary to intracranial aneurysms. These cases are discussed and other cerebrovascular abnormalities that have been described in association with Noonan syndrome are reviewed. Ultrastructural and genetic factors contributing to these associations are considered. (orig.)

  5. Transcatheter Coil Embolization of an Aneurysm of the Pancreatico-duodenal Artery with Occluded Celiac Trunk

    International Nuclear Information System (INIS)

    Weber, C.H.; Pfeifer, K.J.; Tato, F.; Reiser, M.; Rieger, J.

    2005-01-01

    We report on a case of a wide-necked aneurysm of the pancreatico-duodenal artery with occlusion of the celiac trunk in an asymptomatic patient. The aneurysm was considered to be at high risk of rupture. Successful embolization after interdisciplinary consultation was followed with color-coded duplex ultrasound (CCDS) demonstrating significant flow reduction. Three weeks later CCDS and angiography demonstrated exclusion of the aneurysm and a patent arterial supply of the liver and spleen fed by superior mesenteric artery (SMA) collaterals. The patient has done well so far, without major adverse clinical events or evidence for tissue necrosis of the liver, pancreas or spleen. Discussion of the case and review of the literature indicate that transcatheter embolization is the therapy of choice even in complicated cases

  6. Idiopathic intracranial hypertension with altered consciousness in a ...

    African Journals Online (AJOL)

    Idiopathic intracranial hypertension (IIH) is a clinical condition of increased intracranial pressure (ICP) without an obvious underlying pathological brain lesion. It is usually characterized by headache, neck pain, vomiting, visual disturbances, papilledema, cranial nerve palsy or a combination of these signs and symptoms.

  7. Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling - improved image quality by iterative metal artifact reduction

    Energy Technology Data Exchange (ETDEWEB)

    Bier, Georg; Hempel, Johann-Martin; Oergel, Anja; Hauser, Till-Karsten; Ernemann, Ulrike; Hennersdorf, Florian [Eberhard Karls University Tuebingen, Department of Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Bongers, Malte Niklas [Eberhard Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-07-15

    This paper aims to evaluate a new iterative metal artifact reduction algorithm for post-interventional evaluation of brain tissue and intracranial arteries. The data of 20 patients that underwent follow-up cranial CT and cranial CT angiography after clipping or coiling of an intracranial aneurysm was retrospectively analyzed. After the images were processed using a novel iterative metal artifact reduction algorithm, images with and without metal artifact reduction were qualitatively evaluated by two readers, using a five-point Likert scale. Moreover, artifact strength was quantitatively assessed in terms of CT attenuation and standard deviation alterations. The qualitative analysis yielded a significant increase in image quality (p = 0.0057) in iteratively processed images with substantial inter-observer agreement (k = 0.72), while the CTA image quality did not differ (p = 0.864) and even showed vessel contrast reduction in six cases (30%). The mean relative attenuation difference was 27% without metal artifact reduction vs. 11% for iterative metal artifact reduction images (p = 0.0003). The new iterative metal artifact reduction algorithm enhances non-enhanced CT image quality after clipping or coiling, but in CT-angiography images, the contrast of adjacent vessels can be compromised. (orig.)

  8. Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling - improved image quality by iterative metal artifact reduction

    International Nuclear Information System (INIS)

    Bier, Georg; Hempel, Johann-Martin; Oergel, Anja; Hauser, Till-Karsten; Ernemann, Ulrike; Hennersdorf, Florian; Bongers, Malte Niklas

    2017-01-01

    This paper aims to evaluate a new iterative metal artifact reduction algorithm for post-interventional evaluation of brain tissue and intracranial arteries. The data of 20 patients that underwent follow-up cranial CT and cranial CT angiography after clipping or coiling of an intracranial aneurysm was retrospectively analyzed. After the images were processed using a novel iterative metal artifact reduction algorithm, images with and without metal artifact reduction were qualitatively evaluated by two readers, using a five-point Likert scale. Moreover, artifact strength was quantitatively assessed in terms of CT attenuation and standard deviation alterations. The qualitative analysis yielded a significant increase in image quality (p = 0.0057) in iteratively processed images with substantial inter-observer agreement (k = 0.72), while the CTA image quality did not differ (p = 0.864) and even showed vessel contrast reduction in six cases (30%). The mean relative attenuation difference was 27% without metal artifact reduction vs. 11% for iterative metal artifact reduction images (p = 0.0003). The new iterative metal artifact reduction algorithm enhances non-enhanced CT image quality after clipping or coiling, but in CT-angiography images, the contrast of adjacent vessels can be compromised. (orig.)

  9. Comparison of shape memory polymer foam versus bare metal coil treatments in an in vivo porcine sidewall aneurysm model.

    Science.gov (United States)

    Horn, John; Hwang, Wonjun; Jessen, Staci L; Keller, Brandis K; Miller, Matthew W; Tuzun, Egemen; Hartman, Jonathan; Clubb, Fred J; Maitland, Duncan J

    2017-10-01

    The endovascular delivery of platinum alloy bare metal coils has been widely adapted to treat intracranial aneurysms. Despite the widespread clinical use of this technique, numerous suboptimal outcomes are possible. These may include chronic inflammation, low volume filling, coil compaction, and recanalization, all of which can lead to aneurysm recurrence, need for retreatment, and/or potential rupture. This study evaluates a treatment alternative in which polyurethane shape memory polymer (SMP) foam is used as an embolic aneurysm filler. The performance of this treatment method was compared to that of bare metal coils in a head-to-head in vivo study utilizing a porcine vein pouch aneurysm model. After 90 and 180 days post-treatment, gross and histological observations were used to assess aneurysm healing. At 90 days, the foam-treated aneurysms were at an advanced stage of healing compared to the coil-treated aneurysms and showed no signs of chronic inflammation. At 180 days, the foam-treated aneurysms exhibited an 89-93% reduction in cross-sectional area; whereas coiled aneurysms displayed an 18-34% area reduction. The superior healing in the foam-treated aneurysms at earlier stages suggests that SMP foam may be a viable alternative to current treatment methods. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1892-1905, 2017. © 2016 Wiley Periodicals, Inc.

  10. Indentification of inflow zone of cerebral aneurysm by MRA for effective coil embolization

    International Nuclear Information System (INIS)

    Kudo, Takumi; Satow, Tetsu; Yamada, Naoaki; Hyuga, Takanori; Miyamoto, Susumu; Murao, Kenichi

    2008-01-01

    It is important to pack the inflow zone of intracerebral aneurysm to prevent coil compaction or recanalization after coil embolization of the aneurysm. In this study, we report the usefulness of magnetic resonance angiography (MRA) to identify the inflow zone of the aneurysm. Between November 2004 and March 2006, 21 patients (IC paraclinoid, 11 cases; BA tip, 3 cases; A-com, 4 cases; IC-top, 2 cases; P1, 1 case) underwent interventional coil embolization for cerebral aneurysms and MRA was used to try to depict the inflow zone of the aneurysm. We designed a 3D time-of-flight MRA technique targeted to the aneurysm with a large flip angle to emphasize the streamline into the aneurysm. We grasped the position of the inflow zone in the aneurysm by MRA before intervention. The inflow zone was packed by coils tightly with balloon neck remodeling technique anchor catheter assist technique, if necessary. The inflow zone was depicted in all 21 cases by MRA. In sidewall type aneurysms, the inflow zone existed beside the distal neck in all cases. In terminal type aneurysms, the inflow zone existed on an extension line from patent artery. Dome filling was not detected in all cases after treatment. Small neck remnant was detected in 6 cases that slightly increased in 4 cases, vanished in 1 case, remained and unchanged in 1 case 6 months after treatment. None of the cases required additional treatment. For effective coil embolization, it is important to grasp the position of the inflow zone of the aneurysm and to pack the point as tightly as possible. Identification of the inflow zone of aneurysm by MRA is useful for coil embolization. (author)

  11. Computed Tomography Angiography Evaluation of Risk Factors for Unstable Intracranial Aneurysms.

    Science.gov (United States)

    Wang, Guang-Xian; Gong, Ming-Fu; Wen, Li; Liu, Lan-Lan; Yin, Jin-Bo; Duan, Chun-Mei; Zhang, Dong

    2018-03-19

    To evaluate risk factors for instability in intracranial aneurysms (IAs) using computed tomography angiography (CTA). A total of 614 consecutive patients diagnosed with 661 IAs between August 2011 and February 2016 were reviewed. Patients and IAs were divided into stable and unstable groups. Along with clinical characteristics, IA characteristics were evaluated by CTA. Multiple logistic regression analysis was used to identify the independent risk factors associated with unstable IAs. Receiver operating characteristic (ROC) curve analysis was performed on the final model, and optimal thresholds were obtained. Patient age (odds ratio [OR], 0.946), cerebral atherosclerosis (CA; OR, 0.525), and IAs located at the middle cerebral artery (OR, 0.473) or internal carotid artery (OR, 0.512) were negatively correlated with instability, whereas IAs with irregular shape (OR, 2.157), deep depth (OR, 1.557), or large flow angle (FA; OR, 1.015) were more likely to be unstable. ROC analysis revealed threshold values of age, depth, and FA of 59.5 years, 4.25 mm, and 87.8°, respectively. The stability of IAs is significantly affected by several factors, including patient age and the presence of CA. IA shape and location also have an impact on the stability of IAs. Growth into an irregular shape, with a deep depth, and a large FA are risk factors for a change in IAs from stable to unstable. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Novel genetic loci underlying human intracranial volume identified through genome-wide association

    NARCIS (Netherlands)

    Adams, Hieab H H; Hibar, Derrek P; Chouraki, Vincent; Stein, Jason L; Nyquist, Paul A; Rentería, Miguel E; Trompet, Stella; Arias-Vasquez, Alejandro; Seshadri, Sudha; Desrivières, Sylvane; Beecham, Ashley H; Jahanshad, Neda; Wittfeld, Katharina; Van der Lee, Sven J; Abramovic, Lucija; Alhusaini, Saud; Amin, Najaf; Andersson, Micael; Arfanakis, Konstantinos; Aribisala, Benjamin S; Armstrong, Nicola J; Athanasiu, Lavinia; Axelsson, Tomas; Beiser, Alexa; Bernard, Manon; Bis, Joshua C; Blanken, Laura M E; Blanton, Susan H; Bohlken, Marc M; Boks, Marco P; Bralten, Janita; Brickman, Adam M; Carmichael, Owen; Chakravarty, M Mallar; Chauhan, Ganesh; Chen, Qiang; Ching, Christopher R K; Cuellar-Partida, Gabriel; Braber, Anouk Den; Doan, Nhat Trung; Ehrlich, Stefan; Filippi, Irina; Ge, Tian; Giddaluru, Sudheer; Goldman, Aaron L; Gottesman, Rebecca F; Greven, Corina U; Grimm, Oliver; Griswold, Michael E; Guadalupe, Tulio; Hass, Johanna; Haukvik, Unn K; Hilal, Saima; Hofer, Edith; Hoehn, David; Holmes, Avram J; Hoogman, Martine; Janowitz, Deborah; Jia, Tianye; Kasperaviciute, Dalia; Kim, Sungeun; Klein, Marieke; Kraemer, Bernd; Lee, Phil H; Liao, Jiemin; Liewald, David C M; Lopez, Lorna M; Luciano, Michelle; Macare, Christine; Marquand, Andre; Matarin, Mar; Mather, Karen A; Mattheisen, Manuel; Mazoyer, Bernard; McKay, David R; McWhirter, Rebekah; Milaneschi, Yuri; Mirza-Schreiber, Nazanin; Muetzel, Ryan L; Maniega, Susana Muñoz; Nho, Kwangsik; Nugent, Allison C; Loohuis, Loes M Olde; Oosterlaan, Jaap; Papmeyer, Martina; Pappa, Irene; Pirpamer, Lukas; Pudas, Sara; Pütz, Benno; Rajan, Kumar B; Ramasamy, Adaikalavan; Richards, Jennifer S; Risacher, Shannon L; Roiz-Santiañez, Roberto; Rommelse, Nanda; Rose, Emma J; Royle, Natalie A; Rundek, Tatjana; Sämann, Philipp G; Satizabal, Claudia L; Schmaal, Lianne; Schork, Andrew J; Shen, Li; Shin, Jean; Shumskaya, Elena; Smith, Albert V; Sprooten, Emma; Strike, Lachlan T; Teumer, Alexander; Thomson, Russell; Tordesillas-Gutierrez, Diana; Toro, Roberto; Trabzuni, Daniah; Vaidya, Dhananjay; Van der Grond, Jeroen; Van der Meer, Dennis; Van Donkelaar, Marjolein M J; Van Eijk, Kristel R; Van Erp, Theo G M; Van Rooij, Daan; Walton, Esther; Westlye, Lars T; Whelan, Christopher D; Windham, Beverly G; Winkler, Anderson M; Woldehawariat, Girma; Wolf, Christiane; Wolfers, Thomas; Xu, Bing; Yanek, Lisa R; Yang, Jingyun; Zijdenbos, Alex; Zwiers, Marcel P; Agartz, Ingrid; Aggarwal, Neelum T; Almasy, Laura; Ames, David; Amouyel, Philippe; Andreassen, Ole A; Arepalli, Sampath; Assareh, Amelia A; Barral, Sandra; Bastin, Mark E; Becker, Diane M; Becker, James T; Bennett, David A; Blangero, John; van Bokhoven, Hans; Boomsma, Dorret I; Brodaty, Henry; Brouwer, Rachel M; Brunner, Han G; Buckner, Randy L; Buitelaar, Jan K; Bulayeva, Kazima B; Cahn, Wiepke; Calhoun, Vince D; Cannon, Dara M; Cavalleri, Gianpiero L; Chen, Christopher; Cheng, Ching-Yu; Cichon, Sven; Cookson, Mark R; Corvin, Aiden; Crespo-Facorro, Benedicto; Curran, Joanne E; Czisch, Michael; Dale, Anders M; Davies, Gareth E; De Geus, Eco J C; De Jager, Philip L; de Zubicaray, Greig I; Delanty, Norman; Depondt, Chantal; DeStefano, Anita L; Dillman, Allissa; Djurovic, Srdjan; Donohoe, Gary; Drevets, Wayne C; Duggirala, Ravi; Dyer, Thomas D; Erk, Susanne; Espeseth, Thomas; Evans, Denis A; Fedko, Iryna O; Fernández, Guillén; Ferrucci, Luigi; Fisher, Simon E; Fleischman, Debra A; Ford, Ian; Foroud, Tatiana M; Fox, Peter T; Francks, Clyde; Fukunaga, Masaki; Gibbs, J Raphael; Glahn, David C; Gollub, Randy L; Göring, Harald H H; Grabe, Hans J; Green, Robert C; Gruber, Oliver; Gudnason, Vilmundur; Guelfi, Sebastian; Hansell, Narelle K; Hardy, John; Hartman, Catharina A; Hashimoto, Ryota; Hegenscheid, Katrin; Heinz, Andreas; Le Hellard, Stephanie; Hernandez, Dena G; Heslenfeld, Dirk J; Ho, Beng-Choon; Hoekstra, Pieter J; Hoffmann, Wolfgang; Hofman, Albert; Holsboer, Florian; Homuth, Georg; Hosten, Norbert; Hottenga, Jouke-Jan; Pol, Hilleke E Hulshoff; Ikeda, Masashi; Ikram, M Kamran; Jack, Clifford R; Jenkinson, Mark; Johnson, Robert; Jönsson, Erik G; Jukema, J Wouter; Kahn, René S; Kanai, Ryota; Kloszewska, Iwona; Knopman, David S; Kochunov, Peter; Kwok, John B; Lawrie, Stephen M; Lemaître, Hervé; Liu, Xinmin; Longo, Dan L; Longstreth, W T; Lopez, Oscar L; Lovestone, Simon; Martinez, Oliver; Martinot, Jean-Luc; Mattay, Venkata S; McDonald, Colm; McIntosh, Andrew M; McMahon, Katie L; McMahon, Francis J; Mecocci, Patrizia; Melle, Ingrid; Meyer-Lindenberg, Andreas; Mohnke, Sebastian; Montgomery, Grant W; Morris, Derek W; Mosley, Thomas H; Mühleisen, Thomas W; Müller-Myhsok, Bertram; Nalls, Michael A; Nauck, Matthias; Nichols, Thomas E; Niessen, Wiro J; Nöthen, Markus M; Nyberg, Lars; Ohi, Kazutaka; Olvera, Rene L; Ophoff, Roel A; Pandolfo, Massimo; Paus, Tomas; Pausova, Zdenka; Penninx, Brenda W J H; Pike, G Bruce; Potkin, Steven G; Psaty, Bruce M; Reppermund, Simone; Rietschel, Marcella; Roffman, Joshua L; Romanczuk-Seiferth, Nina; Rotter, Jerome I; Ryten, Mina; Sacco, Ralph L; Sachdev, Perminder S; Saykin, Andrew J; Schmidt, Reinhold; Schofield, Peter R; Sigurdsson, Sigurdur; Simmons, Andy; Singleton, Andrew; Sisodiya, Sanjay M; Smith, Colin; Smoller, Jordan W; Soininen, Hilkka; Srikanth, Velandai; Steen, Vidar M; Stott, David J; Sussmann, Jessika E; Thalamuthu, Anbupalam; Tiemeier, Henning; Toga, Arthur W; Traynor, Bryan J; Troncoso, Juan; Turner, Jessica A; Tzourio, Christophe; Uitterlinden, Andre G; Hernández, Maria C Valdés; Van der Brug, Marcel; Van der Lugt, Aad; Van der Wee, Nic J A; Van Duijn, Cornelia M; Van Haren, Neeltje E M; Van T Ent, Dennis; Van Tol, Marie-Jose; Vardarajan, Badri N; Veltman, Dick J; Vernooij, Meike W; Völzke, Henry; Walter, Henrik; Wardlaw, Joanna M; Wassink, Thomas H; Weale, Michael E; Weinberger, Daniel R; Weiner, Michael W; Wen, Wei; Westman, Eric; White, Tonya; Wong, Tien Y; Wright, Clinton B; Zielke, H Ronald; Zonderman, Alan B; Deary, Ian J; DeCarli, Charles; Schmidt, Helena; Martin, Nicholas G; De Craen, Anton J M; Wright, Margaret J; Launer, Lenore J; Schumann, Gunter; Fornage, Myriam; Franke, Barbara; Debette, Stéphanie; Medland, Sarah E; Ikram, M Arfan; Thompson, Paul M

    2016-01-01

    Intracranial volume reflects the maximally attained brain size during development, and remains stable with loss of tissue in late life. It is highly heritable, but the underlying genes remain largely undetermined. In a genome-wide association study of 32,438 adults, we discovered five previously

  13. Hemothorax due to Ruptured Mycotic Aneurysm of Intercostal Arteries Associated with Infective Endocarditis

    Directory of Open Access Journals (Sweden)

    Eddie Y. Liu

    2017-01-01

    Full Text Available We present a case of hemothorax due to ruptured mycotic aneurysm in three intercostal arteries in a 40-year-old male with methicillin-resistant Staphylococcus aureus infective endocarditis (IE due to intravenous drug use. Microcoil embolization and thoracotomy successfully achieved hemostasis. Mycotic aneurysm is a rare complication of IE and is usually found in the intracranial vessels. Ruptured mycotic aneurysm in the intercostal arteries can be associated with IE and can present as acute hemothorax.

  14. Diagnostic value of 3D time-of-flight magnetic resonance angiography for detecting intracranial aneurysm: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Liu, HaiFeng; Xu, YongSheng [First Hospital of LanZhou University, Department of Radiology, Lanzhou, Gansu (China); First Clinical Medical College of LanZhou University, Lanzhou, Gansu (China); Xun, YangQin [Lanzhou University, Evidence-based Medicine Center, Lanzhou (China); Dou, Yu; Wang, ShuaiWen; Lu, XingRu; Lei, JunQiang [First Hospital of LanZhou University, Department of Radiology, Lanzhou, Gansu (China)

    2017-11-15

    This meta-analysis is to comprehensively evaluate the diagnostic performance of three-dimensional time-of-flight magnetic resonance angiography (3D-TOF-MRA) for detecting intracranial aneurysm (IA). PubMed, Embase, Web of Science, and the Cochrane library were systematically searched for retrieving eligible studies. Study inclusion, data extraction, and risk of bias assessment were performed by two researchers independently. Pooled sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) were calculated to assess the diagnostic value. In addition, heterogeneity and subgroup analysis were carried out. In total, 18 studies comprising 3463 patients were selected. The results of 3D-TOF-MRA for diagnosing IA were SEN 0.89 (95% CI 0.82-0.94), SPE 0.94 (0.86-0.97), PLR 13.79 (5.92-32.12), NLR 0.11 (0.07-0.19), DOR 121.90 (38.81-382.94), and AUC 0.96 (0.94-0.98), respectively. In the subgroup analysis, studies without subarachnoid hemorrhage (SAH) tend to perform statistical significantly better (P < 0.05) in detecting IAs than studies with SAH 0.99 (0.98-1.00) vs. 0.89 (0.86-0.91). The diagnostic value of studies with a two-image reconstruction method was higher than studies with only one image reconstruction method: 0.99 (0.98-1.00) vs. 0.91 (0.89-0.94) with P < 0.05. The 3D-TOF-MRA had better SEN in aneurysms > 3 mm than the aneurysms ≤ 3 mm in diameter: 0.89 (0.87-0.92) vs. 0.78 (0.71-0.84) with P < 0.05. This study demonstrated that 3D-TOF-MRA has an excellent diagnostic performance for the overall assessment of IA and may serve as an alternative for further patient management with IA. (orig.)

  15. Rare Coding Variants in ANGPTL6 Are Associated with Familial Forms of Intracranial Aneurysm.

    Science.gov (United States)

    Bourcier, Romain; Le Scouarnec, Solena; Bonnaud, Stéphanie; Karakachoff, Matilde; Bourcereau, Emmanuelle; Heurtebise-Chrétien, Sandrine; Menguy, Céline; Dina, Christian; Simonet, Floriane; Moles, Alexis; Lenoble, Cédric; Lindenbaum, Pierre; Chatel, Stéphanie; Isidor, Bertrand; Génin, Emmanuelle; Deleuze, Jean-François; Schott, Jean-Jacques; Le Marec, Hervé; Loirand, Gervaise; Desal, Hubert; Redon, Richard

    2018-01-04

    Intracranial aneurysms (IAs) are acquired cerebrovascular abnormalities characterized by localized dilation and wall thinning in intracranial arteries, possibly leading to subarachnoid hemorrhage and severe outcome in case of rupture. Here, we identified one rare nonsense variant (c.1378A>T) in the last exon of ANGPTL6 (Angiopoietin-Like 6)-which encodes a circulating pro-angiogenic factor mainly secreted from the liver-shared by the four tested affected members of a large pedigree with multiple IA-affected case subjects. We showed a 50% reduction of ANGPTL6 serum concentration in individuals heterozygous for the c.1378A>T allele (p.Lys460Ter) compared to relatives homozygous for the normal allele, probably due to the non-secretion of the truncated protein produced by the c.1378A>T transcripts. Sequencing ANGPTL6 in a series of 94 additional index case subjects with familial IA identified three other rare coding variants in five case subjects. Overall, we detected a significant enrichment (p = 0.023) in rare coding variants within this gene among the 95 index case subjects with familial IA, compared to a reference population of 404 individuals with French ancestry. Among the 6 recruited families, 12 out of 13 (92%) individuals carrying IA also carry such variants in ANGPTL6, versus 15 out of 41 (37%) unaffected ones. We observed a higher rate of individuals with a history of high blood pressure among affected versus healthy individuals carrying ANGPTL6 variants, suggesting that ANGPTL6 could trigger cerebrovascular lesions when combined with other risk factors such as hypertension. Altogether, our results indicate that rare coding variants in ANGPTL6 are causally related to familial forms of IA. Copyright © 2017 American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  16. Treatment of carotid artery aneurysms with covered stents; Aneurysmabehandlung der Arteria carotis interna mit gecoverten Stents

    Energy Technology Data Exchange (ETDEWEB)

    Rohr, A.; Alfke, K.; Doerner, L.; Jansen, O. [UKSH Kiel (Germany). Neurochirurgie Neuroradiologie; Bartsch, T.; Stingele, R. [UKSH Kiel (Germany). Neurologie

    2007-10-15

    Purpose: Evaluation of the use of covered stents in treating pseudoaneurysms of the cervical and intracranial/extradural carotid artery and determination of the periprocedural and short- to mid-term complication rate. Materials and Methods: 8 patients with 9 spontaneous dissecting aneurysms of the cervical carotid artery - 5 of which were symptomatic - plus one patient with ofthalmoplegia due to an aneurysm of the cavernous carotid artery were studied. While the latter was treated with a PTFE-covered balloon-mounted stainless steel stent (Jostent/Graftmaster), a self-expanding PTFE-covered Nitonol Stent (Symbiot) was used in all other cases. Intervention was performed with local anesthesia. Aspirin and Clopidogrel were both used as antiplatelet drugs. Clinical signs and symptoms and vascular imaging with DS, MR, CT angiography and ultrasound were recorded during patient follow-up, with a mean follow-up period of 14.6 months (4 - 30). Results: We were able to treat 8 out of 10 aneurysms (80 %) using covered stents. The aneurysms were immediately occluded and the associated stenoses of the parent vessel were eliminated. No clinically relevant complications occurred during the procedure or in the follow-up interval. In two cases, elongation of the carotid artery prevented the stent from being positioned over the aneurysm neck. These cases were shown to be stable with the use of antiplatelet drugs. Conclusion: Covered stents can be used in the treatment of pseudoaneurysms of the carotid artery as an alternative to long-term antithrombotic medication or surgery. In our study treatment was effective (80 %) and free of complications in the short- and mid-term follow-up. Possible indications, technique and the use of imaging modalities for patient follow-up are discussed. (orig.)

  17. Delayed Rebleeding of Cerebral Aneurysm Misdiagnosed as Traumatic Subarachnoid Hemorrhage

    OpenAIRE

    Song, Seung-Yoon; Kim, Dae-Won; Park, Jong-Tae; Kang, Sung-Don

    2016-01-01

    An intracranial saccular aneurysm is uncommonly diagnosed in a patient with closed head trauma. We herein present a patient with delayed rebleeding of a cerebral aneurysm misdiagnosed as traumatic subarachnoid hemorrhage (SAH). A 26-year-old female visited our emergency department because of headache after a motorcycle accident. Brain computed tomography (CT) showed a right-side dominant SAH in Sylvian fissure. Although traumatic SAH was strongly suggested because of the history of head traum...

  18. The preparation of aneurysm model in rabbits by vessel ligation and elastase-induced technique

    International Nuclear Information System (INIS)

    Lu Chuan; Xie Qianyu; Liu Linxiang

    2010-01-01

    Objective: To establish an aneurysm model, which is quite similar to the human intracranial aneurysm in morphology, in rabbits by means of vessel ligation together with elastase-induced technique. Methods: Sixteen New Zealand white rabbits were used in this study. Distal carotid ligation and intraluminal elastase incubation was employed in ten rabbits (study group) to create aneurysm on the right common carotid artery. And surgical suture of a segment of the left carotid common artery was carried out in six rabbits (used as control group) to establish the aneurysm model. DSA exam of the created aneurysms by using catheterization via femoral artery was performed at one week and at one month after surgery. The patency, morphology and pathology of the aneurysms were observed. The results were statistically analyzed. Results: The aneurysms in both groups remained patent after they were created. Angiography one week after the surgery showed that all the aneurysms in study group were patent, while in control group only two aneurysms showed opacification with contrast medium and the remaining four aneurysms were all occluded. DSA at one month after the procedure demonstrated that all the aneurysms in study group remained patent, and the previous two patent aneurysms in control group became occluded. The mean width and length of the aneurysmal cavity in study group immediately after the procedure were (3.70 ± 0.16) mm and (6.53 ± 0.65) mm respectively, which enlarged to (5.06 ± 0.31) mm and (9.0 ± 0.52) mm respectively one month after the surgery. The difference in size changes was statistically significant (P < 0.05). Pathologically, almost complete absence of the internal elastic lamina and medial wall elastin of the aneurysms was observed. Conclusion: The aneurysm model prepared with vessel ligation together with elastase-induced technique carries high patent rate and possesses the feature of spontaneous growing, moreover, its morphology is quite similar to the

  19. Sequential changes of magnetic resonance images of intracavernous giant aneurysm following carotid ligation

    International Nuclear Information System (INIS)

    Kinjo, Toshihiko; Mukawa, Jiro; Takara, Eiichi; Mekaru, Susumu; Ishikawa, Yasunari

    1986-01-01

    A case of intracavernous giant aneurysm treated by combined carotid ligation and extracranial-intracranial vein-graft bypass is reported with special reference to the sequential changes of Magnetic Resonance Images (MRI). A 29-year-old female was admitted to our clinic with complaint of diplopia. She had no neurological deficit except for left abducens palsy. Left carotid angiogram revealed an intracavernous giant aneurysm, and vertebral angiogram revealed a fenestration at right and an aneurysm-like buldging at left vertebral artery. Gradual carotid occlusion after extracranial-intracranial bypass via grafted saphnous vein was successfully performed without any neurological complications. Sequential changes of MRI were as follows: The aneurysm was shown by absent intensity both in spin echo (SE) and inversion recovery (IR) methods before the treatment. It became isointensity in SE and two-tone intensity, iso at the center and high at the margin, in IR 15 days after, and, furtheremore, became slight high intensity in SE but decreased in two-tone intensity, low at the center and high at the margin, in IR 37 days after complete carotid occlusion. Coronal view was usefull to understand anatomical relationship. In conclusion, MRI, especially coronal IR method is of more diagnostic value than X-ray CT to follow the thrombosis of intracavernous aneurysm. (author)

  20. Factors responsible for poor outcome after intraprocedural rerupture of ruptured intracranial aneurysms: Identification of risk factors, prevention and management on 18 cases

    International Nuclear Information System (INIS)

    Zhang Xin; Long Xiaoao; Luo Bin; Karuna, Tamrakar; Duan Chuanzhi

    2012-01-01

    Purpose: The paper mainly involved the retrospective approach to risk factors of intraprocedual rerupture (IPR) and illustration of our empirical prevention and management on this event as well as its postembolization outcomes evaluation. Materials and methods: Endovascular treatment was performed in 1308 patients with 1308 ruptured intracranial aneurysms, and IPR occurred in 18 cases. We retrospectively reviewed their clinical records and images, and analysis risk factors of IPR by using multivariate logistic regression. Results: The morbidity of IPR was 1.38% and mortality was 33.33%. Nine patients survived from rapid completion of coiling with immediate reversal of heparin anticoagulation with protamine sulfate, and 3 from emergent external ventricular drainage (EVD). However, 9 of them presented with different degrees of disability and 3 were fully recovered. Small aneurysms (diameter ≤ 3.0 mm) (OR 284.212, 95% C.I. 17.368–4650.780, P = 0.000), atherosclerosis (OR 7.866, 95% C.I. 1.113–55.570, P = 0.039), Fisher Grade III (OR 82.099, 95% C.I. 1.563–431.696, P = 0.029), vasospasm (grade I) (OR 32.269, 95% C.I. 2.393–435.132, P = 0.009) and vasospasm (grade II) (OR 30.238, 95% C.I. 1.770–516.552, P = 0.019) are risk factors of IPR. Aneurysms at proximal part of internal carotid artery (ICA), bifurcation and basilar artery (BA) stem (OR 0.003, 95% C.I. 0.000–0.101, P = 0.001) and Hunt and Hess Grade II (OR 0.010, 95% C.I. 0.000–0.346, P = 0.011) are identified as protective factors. Conclusions: Small aneurysms, atherosclerosis, Fisher Grade of SAH and cerebral vasospasm are the predictors of IPR. Aneurysms at proximal part of ICA bifurcation and BA stem and Hunt and Hess Grade II are less associated with IPR. Rapid completion of coiling combined with immediate reversal of heparin anticoagulation is confirmed to be the best strategy in our series.

  1. Advances in endovascular aneurysm treatment: are we making a difference?

    International Nuclear Information System (INIS)

    Katz, Jeffrey M.; Ougorets, Igor; Tsiouris, Apostolos J.; Biondi, Alessandra; Salvaggio, Kimberly A.; Gobin, Y. Pierre; Stieg, Philip E.; Riina, Howard A.

    2005-01-01

    Recent advancements in endovascular aneurysm repair, including bioactive and expansile coils and intracranial stents, hold promise for improved aneurysm occlusion rates. We report the immediate and midterm clinical and angiographic outcomes of a consecutive series of patients treated since the advent of these technologies. Clinical and radiological records of 134 patients with 142 aneurysms treated between 2001 and 2004 were retrospectively evaluated by an independent neurologist. Endovascular procedures were analyzed by an independent neuroradiologist blinded to all clinical information. Seventy-two ruptured and 60 un-ruptured saccular aneurysms, nine fusiform and one post-traumatic aneurysm were treated. Matrix coils were used in 53% of saccular aneurysms and HydroCoils in 13% of all aneurysms. Neuroform stents were deployed in 19% of aneurysms. Angiographic total or subtotal occlusion was achieved in 76% of cases and in 96% at last follow-up. Aneurysm recanalization was observed in 14% over a mean follow-up of 12 months, and 18% of aneurysms were retreated. Clinically relevant complications occurred in 6.0%, resulting in procedure-related morbidity of 0.6% and 0.6% mortality at 6 months. No aneurysm bled over a cumulative 1,347 months of observation. Newer embolization technologies can be exploited successfully even in more complex aneurysms with very low morbidity and mortality. (orig.)

  2. Volume changes of extremely large and giant intracranial aneurysms after treatment with flow diverter stents

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Angelo; Byrne, James V. [ohn Radcliffe Hospital, Oxford Neurovascular and Neuroradiology Research Unit, Nuffield Department of Surgical Sciences, Oxford (United Kingdom); Rane, Neil; Kueker, Wilhelm; Cellerini, Martino; Corkill, Rufus [John Radcliffe Hospital, Department of Neuroradiology, Oxford (United Kingdom)

    2014-01-15

    This study assessed volume changes of unruptured large and giant aneurysms (greatest diameter >20 mm) after treatment with flow diverter (FD) stents. Clinical audit of the cases treated in a single institution, over a 5-year period. Demographic and clinical data were retrospectively collected from the hospital records. Aneurysm volumes were measured by manual outlining at sequential slices using computerised tomography (CT) or magnetic resonance (MR) angiography data. The audit included eight patients (seven females) with eight aneurysms. Four aneurysms involved the cavernous segment of the internal carotid artery (ICA), three the supraclinoid ICA and one the basilar artery. Seven patients presented with signs and symptoms of mass effect and one with seizures. All but one aneurysm was treated with a single FD stent; six aneurysms were also coiled (either before or simultaneously with FD placement). Minimum follow-up time was 6 months (mean 20 months). At follow-up, three aneurysms decreased in size, three were unchanged and two increased. Both aneurysms that increased in size showed persistent endosaccular flow at follow-up MR; in one case, failure was attributed to suboptimal position of the stent; in the other case, it was attributed to persistence of a side branch originating from the aneurysm (similar to the endoleak phenomenon of aortic aneurysms). At follow-up, five aneurysms were completely occluded; none of these increased in volume. Complete occlusion of the aneurysms leads, in most cases, to its shrinkage. In cases of late aneurysm growth or regrowth, consideration should be given to possible endoleak as the cause. (orig.)

  3. Treatment of Unruptured Intracranial Aneurysms and Cognitive Performance: Preliminary Results of a Prospective Clinical Trial.

    Science.gov (United States)

    Bründl, Elisabeth; Böhm, Christina; Lürding, Ralf; Schödel, Petra; Bele, Sylvia; Hochreiter, Andreas; Scheitzach, Judith; Zeman, Florian; Brawanski, Alexander; Schebesch, Karl-Michael

    2016-10-01

    Few studies have addressed the effect of treatment of unruptured intracranial aneurysm (UIA) on cognitive function. Neuropsychological assessment after UIA treatment is underreported, and prospective trials have repeatedly been demanded. In 2014, we conducted a prospective controlled study to evaluate the differences in cognitive processing caused by the treatment of anterior circulation UIAs. Thirty patients were enrolled until September 2015. Ten patients received endovascular aneurysm occlusion (EV), 10 patients were treated microsurgically (MS), and 10 patients with surgically treated degenerative lumbar spine disease (LD) served as control. All patients underwent extended standardized neuropsychological assessment before (t 1 ) and 6 weeks after treatment (t 2 ). Tests included verbal, visual, and visuospatial memory, psychomotor functioning, executive functioning, and its subdomains verbal fluency and cognitive flexibility. We statistically evaluated intragroup and intergroup changes. Intragroup comparisons and group-rate analysis showed no significant impairment in overall neuropsychological performance, either postinterventionally or postoperatively. However, the postoperative performance in cognitive processing speed, cognitive flexibility, and executive functioning was significantly worse in the MS group than in the EV (P = 0.038) and LD group (P = 0.02). Compared with the EV group, patients with MS showed significant postoperative impairment in a subtest for auditory-verbal memory (Wechsler Memory Scale, Fourth Edition, Logical Memory II; MS vs. EV P = 0.011). The MS group trended toward posttreatment impairment in subtests for verbal fluency and semantic memory (Regensburg Word Fluency Test; MS vs. EV P = 0.083) and in auditory-verbal memory (Wechsler Memory Scale, Fourth Edition, Logical Memory II; MS vs. LD P = 0.06). Our preliminary data showed no effect of anterior circulation UIA treatment on overall neuropsychological function but impaired

  4. Magnetic Resonance Imaging Susceptibility-Weighted Imaging Lesion and Contrast Enhancement May Represent Infectious Intracranial Aneurysm in Infective Endocarditis.

    Science.gov (United States)

    Cho, Sung-Min; Rice, Cory; Marquardt, Robert J; Zhang, Lucy Q; Khoury, Jean; Thatikunta, Prateek; Buletko, Andrew B; Hardman, Julian; Uchino, Ken; Wisco, Dolora

    2017-01-01

    Infectious intracranial aneurysm (IIA) can complicate infective endocarditis (IE). We aimed to describe the magnetic resonance imaging (MRI) characteristics of IIA. We reviewed IIAs among 116 consecutive patients with active IE by conducting a neurological evaluation at a single tertiary referral center from January 2015 to July 2016. MRIs and digital cerebral angiograms (DSA) were reviewed to identify MRI characteristics of IIAs. MRI susceptibility weighted imaging (SWI) was performed to collect data on cerebral microbleeds (CMBs) and sulcal SWI lesions. Out of 116 persons, 74 (63.8%) underwent DSA. IIAs were identified in 13 (17.6% of DSA, 11.2% of entire cohort) and 10 patients with aneurysms underwent MRI with SWI sequence. Nine (90%) out of 10 persons with IIAs had CMB >5 mm or sulcal lesions in SWI (9 in sulci, 6 in parenchyma, and 5 in both). Five out of 8 persons who underwent MRI brain with contrast had enhancement within the SWI lesions. In a multivariate logistic regression analysis, both sulcal SWI lesions (p < 0.001, OR 69, 95% CI 7.8-610) and contrast enhancement (p = 0.007, OR 16.5, 95% CI 2.3-121) were found to be significant predictors of the presence of IIAs. In the individuals with IE who underwent DSA and MRI, we found that neuroimaging characteristics, such as sulcal SWI lesion with or without contrast enhancement, are associated with the presence of IIA. © 2017 S. Karger AG, Basel.

  5. Successful Endovascular Treatment of a Left Common Carotid Artery Aneurysm Following Failed Surgery of a Right Common Carotid Artery Aneurysm

    International Nuclear Information System (INIS)

    Cil, Barbaros E.; Ucar, Ibrahim; Ozsoy, Fatma; Arat, Anil; Yorgancioglu, Cem; Boeke, Erkmen

    2005-01-01

    Aneurysm of the common carotid artery is a rare and serious disease requiring prompt treatment in order to avoid neurologic complications. A 39-year-old man presented with voice impairment and a pulsatile mass at the right side of his neck and was found by color Doppler examination to have bilateral common carotid artery aneurysms of unknown origin. The right-sided large aneurysm was treated with placement of an 8 mm interposition Gore-Tex graft between the right common and internal carotid arteries. The surgical graft thrombosed 7 days after the surgery but the left-sided aneurysm was successfully treated by a Jostent peripheral stent-graft. Color Doppler examination showed a patent stent and no filling of the aneurysm on his first and sixth-month follow-up. Bilateral common carotid artery aneurysm is an exceptionally unusual condition and endovascular treatment of carotid artery aneurysms with covered stents may become an effective treatment alternative for these lesions

  6. Anterior petroclinoid fold fenestration: an adjunct to clipping of postero-laterally projecting posterior communicating aneurysms.

    Science.gov (United States)

    Nossek, Erez; Setton, Avi; Dehdashti, Amir R; Chalif, David J

    2014-10-01

    Proximally located posterior communicating artery (PCoA) aneurysms, projecting postero-laterally in proximity to the tentorium, may pose a technical challenge for microsurgical clipping due to obscuration of the proximal aneurysmal neck by the anterior petroclinoid fold. We describe an efficacious technique utilizing fenestration of the anterior petroclinoid fold to facilitate visualization and clipping of PCoA aneurysms abutting this aspect of the tentorium. Of 86 cases of PCoA aneurysms treated between 2003 and 2013, the technique was used in nine (10.5 %) patients to allow for adequate clipping. A 3 mm fenestration in the anterior petroclinoid ligament is created adjacent and lateral to the anterior clinoid process. This fenestration is then widened into a small wedge corridor by bipolar coagulation. In all cases, the proximal aneurysm neck was visualized after the wedge fenestration. Additionally, an adequate corridor for placement of the proximal clip blade was uniformly established. All cases were adequately clipped, with complete occlusion of the aneurysm neck and fundus with preservation of the PCoA. There were two intraoperative ruptures not related to creation of the wedge fenestration. One patient experienced post-operative partial third nerve palsy, which resolved during follow-up. We describe a technique of fenestration of the anterior petroclinoid fold to establish a critical and safe corridor for both visualization and clipping of PCoA aneurysms.

  7. Simulation of Intra-Aneurysmal Blood Flow by Different Numerical Methods

    Directory of Open Access Journals (Sweden)

    Frank Weichert

    2013-01-01

    Full Text Available The occlusional performance of sole endoluminal stenting of intracranial aneurysms is controversially discussed in the literature. Simulation of blood flow has been studied to shed light on possible causal attributions. The outcome, however, largely depends on the numerical method and various free parameters. The present study is therefore conducted to find ways to define parameters and efficiently explore the huge parameter space with finite element methods (FEMs and lattice Boltzmann methods (LBMs. The goal is to identify both the impact of different parameters on the results of computational fluid dynamics (CFD and their advantages and disadvantages. CFD is applied to assess flow and aneurysmal vorticity in 2D and 3D models. To assess and compare initial simulation results, simplified 2D and 3D models based on key features of real geometries and medical expert knowledge were used. A result obtained from this analysis indicates that a combined use of the different numerical methods, LBM for fast exploration and FEM for a more in-depth look, may result in a better understanding of blood flow and may also lead to more accurate information about factors that influence conditions for stenting of intracranial aneurysms.

  8. Non-traumatic neurological emergencies: emergency neuroradiological interventions

    Energy Technology Data Exchange (ETDEWEB)

    Schroth, Gerhard; Loevblad, Karl-Olof; Ozdoba, Christoph; Remonda, Luca [Department of Neuroradiology, University of Bern, Inselspital (Switzerland)

    2002-07-01

    This article summarizes recent developments in the growing field of interventional neuroradiology for the treatment of acute cerebrovascular disease. We describe the possibilities in endovascular therapy of acute cerebral aneurysms using electrolytically detachable coils combined with trispan neck bridging devices and stent implantation to occlude acute wide neck aneurysms. Techniques and results of local intra-arterial thrombolytic therapy in acute stroke and central retinal artery occlusion are described and we discuss the potential for rapid, large-burden thrombus removal in cases of internal carotid artery thrombosis by rheolytic thrombectomy, percutaneous transluminal angioplasty and stent implantation. Emergency endovascular therapy using the transvenous approach to treat severe intracranial or intraocular hypertension and multifocal haemorrhagic venous infarction due to cerebral sinus thrombosis or dural fistulas is also described. In cases of acute bleeding of head and neck lesions following trauma, tumours after radiotherapy, arteriovenous malformations, epistaxis or from iatrogenic origin, angiography plays a major role in localizing the source of bleeding and occluding the damaged vessel during the same session using the same endovascular approach. (orig.)

  9. Non-traumatic neurological emergencies: emergency neuroradiological interventions

    International Nuclear Information System (INIS)

    Schroth, Gerhard; Loevblad, Karl-Olof; Ozdoba, Christoph; Remonda, Luca

    2002-01-01

    This article summarizes recent developments in the growing field of interventional neuroradiology for the treatment of acute cerebrovascular disease. We describe the possibilities in endovascular therapy of acute cerebral aneurysms using electrolytically detachable coils combined with trispan neck bridging devices and stent implantation to occlude acute wide neck aneurysms. Techniques and results of local intra-arterial thrombolytic therapy in acute stroke and central retinal artery occlusion are described and we discuss the potential for rapid, large-burden thrombus removal in cases of internal carotid artery thrombosis by rheolytic thrombectomy, percutaneous transluminal angioplasty and stent implantation. Emergency endovascular therapy using the transvenous approach to treat severe intracranial or intraocular hypertension and multifocal haemorrhagic venous infarction due to cerebral sinus thrombosis or dural fistulas is also described. In cases of acute bleeding of head and neck lesions following trauma, tumours after radiotherapy, arteriovenous malformations, epistaxis or from iatrogenic origin, angiography plays a major role in localizing the source of bleeding and occluding the damaged vessel during the same session using the same endovascular approach. (orig.)

  10. Ruptured Aneurysms of the Occipital Artery Associated with Congenital Occipital Bone Defect.

    Science.gov (United States)

    Kawasaki, Toshinari; Yoshida, Kazumichi; Kikuchi, Takayuki; Ishii, Akira; Takagi, Yasushi; Miyamoto, Susumu

    2017-01-01

    Traumatic aneurysms of the superficial temporal artery have been frequently reported in the literature, whereas traumatic aneurysms of the occipital artery (OA) are extremely rare. A 30-year-old man had been followed at another hospital for meningoencephalocele associated with his congenital occipital bone defect. He was admitted to our hospital with a chief complaint of neck swelling and pain during a football game. Computed tomography and magnetic resonance imaging showed a hematoma in his right neck along with the meningoencephalocele. In addition, it showed an atrophic cerebellum with a cyst protruding from his occipital bone defect. Digital subtraction angiography of the right OA showed 3 aneurysms responsible for the large hematoma in his neck. Endovascular embolization with 20% N-butyl-2-cyanoacrylate was performed for treatment of the ruptured aneurysms followed by emergent surgical evacuation of the hematoma. An occipital cranioplasty with titanium mesh was performed 10 months after the emergent intervention. In this patient, the congenital occipital bone defect with meningoencephalocele might have been the remote source of risk for traumatic pseudoaneurysms along the muscle branches of the OA. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Dissecting aneurysms of posterior communicating artery itself: anatomical, diagnostic, clinical, and therapeutical considerations.

    Science.gov (United States)

    Kocak, Burak; Tureci, Ercan; Kizilkilic, Osman; Islak, Civan; Kocer, Naci

    2013-09-01

    Posterior communicating artery (PCoA) itself is an unusual location for intracranial aneurysms in that isolated dissections or dissecting aneurysms are extremely rare. In the way of correct diagnosis of dissecting aneurysms of PCoA itself, a proper understanding of (1) the anatomy of the PCoA and its perforator branches, (2) some particular diagnostic features, and (3) related clinical aspects is of significant importance. Although there are no established treatment strategies for this particular type of aneurysms, the endovascular approach might be considered as a plausible one. In this paper, our scope was to report five cases with dissecting aneurysm of the PCoA itself and to discuss this rare vascular pathology from anatomical, diagnostic, clinical, and therapeutical perspectives.

  12. Reconstructive endovascular treatment of vertebral artery dissecting aneurysms with the Low-profile Visualized Intraluminal Support (LVIS device.

    Directory of Open Access Journals (Sweden)

    Chuan-Chuan Wang

    Full Text Available The Low-profile Visualized Intraluminal Support (LVIS device is a new generation of self-expanding braided stent recently introduced in China for stent assisted coiling of intracranial aneurysms. The aim of our study is to evaluate the feasibility, safety, and efficacy of the LVIS device in reconstructive treatment of vertebral artery dissecting aneurysms (VADAs.We retrospectively reviewed the neurointerventional database of our institution from June 2014 to May 2016. Patients who underwent endovascular treatment of VADAs with LVIS stents were included in this study. Clinical presentation, aneurysmal characteristics, technical feasibility, procedural complications, and angiographic and clinical follow-up results were evaluated.38 patients with VADAs who underwent treatment with LVIS stent were identified, including 3 ruptured VADAs. All VADAs were successfully treated with reconstructive techniques including the stent-assisted coiling (n = 34 and stenting only (n = 4. Post-procedural complications developed in 3 patients (7.9% including two small brainstem infarctions and one delayed thromboembolic event. Complications resulted in one case of minor permanent morbidity (2.6%. There was no procedure-related mortality. The follow-up angiogram was available in 30 patients at an average of 8.3 months (range, 2 to 30 months, which revealed complete occlusion in 23 patients (76.7%, residual neck in five patients (16.7%, and residual sac in two patients (6.7%. The follow-up of 25 aneurysms with incomplete immediate occlusion revealed 22 aneurysms (88% with improvement in the Raymond class. One aneurysm (3.3% showed recanalization and required retreatment. Clinical followed-up at 5-28 months (mean 14.1 months was achieved in 36 patients because two patients died of pancreatic cancer and basal ganglia hemorrhage, respectively. No new neurologic deterioration or aneurysm (rebleeding was observed.Our preliminary experience with reconstruction of VADAs with

  13. Cerebral aneurysm associated with cardiac myxoma: Case Report

    Directory of Open Access Journals (Sweden)

    Branislava A. Ivanović

    2011-02-01

    Full Text Available Left atrial myxomas are a rare but well known cause of cerebrovascular accidents in young people. Cerebral embolism is the most common cause of cerebral ischemic stroke. The intracranial aneurysm is rarely associated with myxoma. We report the case of a patient who had an operation of PICA aneurysm due to subarachnoid hemorrhage ten months before the discovery of the large left atrial myxoma. Fortunately, the untimely diagnosis of the myxoma did not have other consequences. In order to prevent possible complications of we should keep in mind that these two apparently different entities could be associated.

  14. Posterior Communicating Artery Aneurysm in a 20 Year Old Boy ...

    African Journals Online (AJOL)

    Result: A clinical diagnosis of left third and fourth cranial nerve palsies from intracranial space-occupying lesion was made. Computed tomography and computed tomography angiography confirmed left posterior communicating artery aneurysm. Conclusion: Any degree of pupillary involvement in third nerve palsy, whether ...

  15. The hemodynamics in intracranial aneurysm ruptured region with active contrast leakage during computed tomography angiography

    Science.gov (United States)

    Li, Ming-Lung; Wang, Yi-Chou; Liou, Tong-Miin; Lin, Chao-An

    2014-10-01

    Precise locations of rupture region under contrast agent leakage of five ruptured cerebral artery aneurysms during computed tomography angiography, which is to our knowledge for the first time, were successfully identified among 101 patients. These, together with numerical simulations based on the reconstructed aneurysmal models, were used to analyze hemodynamic parameters of aneurysms under different cardiac cyclic flow rates. For side wall type aneurysms, different inlet flow rates have mild influences on the shear stresses distributions. On the other hand, for branch type aneurysms, the predicted wall shear stress (WSS) correlates strongly with the increase of inlet vessel velocity. The mean and time averaged WSSes at rupture regions are found to be lower than those over the surface of the aneurysms. Also, the levels of the oscillatory shear index (OSI) are higher than the reported threshold value, supporting the assertion that high OSI correlates with rupture of the aneurysm. However, the present results also indicate that OSI level at the rupture region is relatively lower.

  16. Predictors of 30-day perioperative morbidity and mortality of unruptured intracranial aneurysm surgery.

    Science.gov (United States)

    Kerezoudis, Panagiotis; McCutcheon, Brandon A; Murphy, Meghan; Rayan, Tarek; Gilder, Hannah; Rinaldo, Lorenzo; Shepherd, Daniel; Maloney, Patrick R; Hirshman, Brian R; Carter, Bob S; Bydon, Mohamad; Meyer, Fredric; Lanzino, Giuseppe

    2016-10-01

    Large-scale studies examining the incidence and predictors of perioperative complications after surgical clipping of unruptured intracranial aneurysms (UIA) using nationally representative prospectively collected data are lacking in the literature. Using the American College of Surgeons' National Surgical Quality Improvement Program (ACS-NSQIP) dataset, we conducted a retrospective analysis of the complications experienced by patients that underwent surgical management of a UIA between the years of 2007 and 2013. The primary outcomes of interest were mortality within the 30-day perioperative period and adverse discharge disposition to a location other than home. Predictors of morbidity and mortality were elucidated using multivariable logistic regression analyses controlling for available patient demographic, comorbidity, and operative characteristics. 662 patients were identified in the ACS-NSQIP dataset for operative management of an unruptured aneurysm. The observed rates of 30-day mortality and adverse discharge disposition were 2.27% and 19.47%, respectively. A hundred and eight (16.31%) patients developed at least one major complication. On multivariable analysis, death within 30days was significantly associated with increased operative time (OR 1.005 per minute, 95% CI 1.002-1.008) and chronic preoperative corticosteroid use (OR 28.4, 95% CI 1.68-480.42), whereas major complication development was associated with increased operative time (OR 1.004 per minute, 95% CI 1.002-1.006), age (OR 1.017 per year, 95% CI 1-1.034), preoperative dependency (OR 3.3, 95% CI 1.16-9.40) and diabetes mellitus (OR 2.89, 95% CI 1.45-5.75). Lastly, increasing age (OR 1.017 per year, 95% CI 1-1.034) as well as ASA Class 3 (OR 1.73, 95% CI 1.08-2.77) and 4 (OR 2.28, 95% CI 1.1-4.72) were independent predictors of discharge to a location other than home. Our study yields morbidity and mortality benchmarks for UIA surgery in a representative, national surgical registry. It will

  17. Dissecting aneurysm of the cervical internal carotid artery. Cervical CT scan findings and treatment - case report

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Yoshihiro; Itoyama, Youichi; Fukumura, Akinobu; Matsukado, Yasuhiko; Kodama, Takafumi

    1987-06-01

    On lifting a heavy case, a 51-year-old male experienced a sudden onset of headache with giddiness and clouded vision. A week later, vertigo and right hand numbness were added to his symptoms. The next day anisocoria (right > left) and dilation of the left retinal veins were noted. Cranial computed tomography (CT) scan appeared normal and there were no other remarkable neurological findings. The patient was treated conservatively for cerebral infarction, however, the headache worsened and diplopia occurred. Neurological examination on admission revealed nothing unusual except for left Horner's syndrome. Physical examination showed a palpable sausage-like painless tumor on the left side of the neck. Angiography showed a narrowing of the internal carotid artery in the cervical region with a small dissecting aneurysm at the C3 level. Cervical CT scan at the upper C3 level showed a low density lunar defect in the high density section of the enlarged left internal carotid artery. The patient was operated on by superficial temporal artery-middle cerebral artery anastomosis to increase the intracranial blood flow. Postoperatively the symptoms were quickly relieved. Angiography 1 month later showed less narrowing of the carotid artery, though the dissecting aneurysm still remained. Postoperative cervical CT scan showed the left internal carotid artery to be of normal size. The patient returned to his work in normal condition 2 months later. It is emphasized that cervical CT scan may be useful in the diagnosis of this unusual type of cervical dissecting aneurysm.

  18. Surgical management of giant posterior communicating artery aneurysms.

    Science.gov (United States)

    Velat, Gregory J; Zabramski, Joseph M; Nakaji, Peter; Spetzler, Robert F

    2012-09-01

    Giant posterior communicating artery (PCoA) aneurysms (> 25 mm) are rare lesions associated with a poor prognosis and high rates of morbidity and mortality. To review the clinical results of giant PCoA aneurysms surgically treated at our institution, focusing on operative nuances. All cases of giant PCoA aneurysms treated surgically at our institution were identified from a prospectively maintained patient database. Patient demographic factors, medical comorbidities, rupture status, neurological presentation, clinical outcomes, and surgical records were critically reviewed. From 1989 to 2010, 11 patients (10 women) underwent surgical clipping of giant PCoA aneurysms. Presenting signs and symptoms included cranial nerve palsies, diminished mental status, headache, visual changes, and seizures. Five aneurysms were ruptured on admission. All aneurysms were clipped primarily except 1, which was treated by parent artery sacrifice and extracranial-to-intracranial bypass after intraoperative aneurysm rupture. Perioperative morbidity and mortality rates were 36% (4 of 11) and 18.3% (2 of 11), respectively. Excellent or good clinical outcomes, defined as modified Rankin Scale scores ≤ 2, were achieved in 86% (5 of 6) of patients available for long-term clinical follow-up (mean, 12.5 ± 13.6 months). Giant PCoA aneurysms are rare vascular lesions that may present with a variety of neurological signs and symptoms. These lesions can be successfully managed surgically with satisfactory morbidity and mortality rates. To the best of our knowledge, this is the largest surgical series of giant PCoA aneurysms published to date.

  19. Superior cerebellar aneurysm causing subarachnoid haemorrhage in a 17-year-old with alagille syndrome.

    LENUS (Irish Health Repository)

    O'Connell, David

    2012-04-01

    Alagille syndrome is a rare autosomal dominant condition characterised by mutation in Jagged1 gene. Intracranial aneurysms may be seen in this condition and may present as subarachnoid hemorrhage. We describe the first case of superior cerebellar aneurysm rupture causing WFNS grade 1 subarachnoid haemorrhage in a 17-year-old girl. The clinical condition and management of this rare occurrence is discussed with a review of literature.

  20. Diagnostic accuracy of multi-slice computed tomographic angiography in the detection of cerebral aneurysms

    International Nuclear Information System (INIS)

    Haghighatkhah, H. R.; Sabouri, S.; Borzouyeh, F.; Bagherzadeh, M. H.; Bakhshandeh, H.; Jalali, A. H.

    2008-01-01

    Multislice computed tomographic angiography is a rapid and minimally invasive method for the detection of intracranial aneurysms. The purpose of this study was to compare Multislice computed tomographic angiography with digital subtraction angiography In the diagnosis of cerebral aneurysms. Patients and Methods: In this cross sectional study we evaluated 111 consecutive patients [42(37.8%) male and 69(62.2%) female], who were admitted under clinical symptoms and signs. suggestive of harboring an intracranial aneurysm by using a four detector Multislice computed tomographic angiography. Then we compared results of Multislice computed tomographic angiography with digital subtraction angiography results as a gold standard method. Digital subtraction angiography was performed by bilateral selective common carotid artery injections and either unilateral or bilateral vertebral artery injections, as necessary. Multislice computed tomographic angiography images were interpreted by one radiologist and digital subtraction angiography was performed by another radiologist who was blinded to the interpretation of the Multislice computed tomographic angiograms. Results: The mean ±S D age of the patients was 49.1±13.6 years (range: 12-84 years). We performed Multislice computed tomographic in 111 and digital subtraction angiography in 85 patients. The sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratio of Multislice computed tomographic angiography, when compared with digital subtraction angiography as the gold standard, were 100%, 90%, 87.5%, 100%, 10 and 0, respectively. Conclusion: Multislice computed tomographic angiography seems to be an accurate and noninvasive imaging modality in the diagnosis of intracranial aneurysms

  1. Cellular responses of bioabsorbable polymeric material and Guglielmi detachable coil in experimental aneurysms.

    Science.gov (United States)

    Murayama, Yuichi; Viñuela, Fernando; Tateshima, Satoshi; Gonzalez, Nestor R; Song, Joon K; Mahdavieh, Haleh; Iruela-Arispe, Luisa

    2002-04-01

    Acceleration of healing mechanisms is a promising approach to improve current limitations of endovascular aneurysm therapy with the use of platinum coils. We evaluated a new endovascular therapeutic, bioabsorbable polymeric material (BPM), which may promote cellular reaction in the aneurysms. Four different concentrations of lactide/glycolic acid copolymer [poly(D-L-lactic-co-glycolic acid)] (PLGA), 85/15, 75/25, 65/35, and 50/50, were used as BPMs. Sixteen experimental aneurysms were created in 8 swine. Eight-millimeter-long spiral-shaped BPMs were surgically implanted in the aneurysms without tight packing (n=3 for each BPM). Guglielmi detachable coils (GDCs) were used as control (n=4). The animals were killed 14 days after embolization, and angiographic, histological, and immunohistochemical analyses were performed. Despite loose packing of aneurysms with BPMs, faster BPMs such as 50/50 or 65/35 PLGA demonstrated more mature collagen formation and fibrosis in the sac and neck of the aneurysm. One aneurysm treated with 65/35 PLGA, 1 treated with 75/25 PLGA, and all 3 treated with 85/15 PLGA showed a neck remnant on angiography. There was a linear relationship between collagen levels and polymer degradation properties (r=-0.9513). This preliminary animal study indicates that acceleration of aneurysm healing with the use of BPM is feasible. This concept can be applied to decrease and perhaps prevent aneurysmal recanalization after endovascular treatment of cerebral aneurysms.

  2. Noninvasive follow-up of GDC-treated saccular aneurysms by MR angiography

    International Nuclear Information System (INIS)

    Weber, W.; Henkes, H.; Nahser, H.C.; Roer, N.; Kuehne, D.; Yousry, T.A.; Felber, S.R.

    2001-01-01

    The aim of this study was to determine sensitivity and specificity of magnetic resonance angiography (MRA) for the assessment of durable occlusion of intracranial aneurysms with Guglielmi detachable coils (GDC) and to point out the influence of MRA results in re-intervention strategies. Forty-five patients with 54 aneurysms that were previously treated by endovascular occlusion with GDC were selected for this study. All patients underwent digital subtraction angiography (DSA) and MRA examinations on the same day. The time-of-flight MRA studies were performed on a 1-T scanner. The MRA images were first read by radiologists who were not aware of the DSA results. In a second consensus reading by the neuroradiologists who had performed all interventional procedures of this series, the decision was made as to whether re-treatment was necessary. The distribution of aneurysm sizes, configurations and treatment results were sufficient for an unbiased evaluation. The first blinded evaluation revealed a sensitivity of 71% and a specificity of 95% for MRA assessment of aneurysm reperfusion. In the second consensus reading, the sensitivity increased to 92% and the specificity was 98%. The blinded reading indicates that MRA is a useful adjunct to DSA for the assessment of durable results after endovascular treatment of intracranial aneurysms. In the consensus reading it became obvious that sensitivity and specificity of MRA can be increased to 92 and 98%, respectively, if the results were evaluated by experienced neuroradiologists, including prior knowledge of all other examinations. We have already increased the follow-up intervals for DSA and use MRA intermittently, based on these results. (orig.)

  3. Terson syndrome in aneurysmal subarachnoid hemorrhage-its relation to intracranial pressure, admission factors, and clinical outcome.

    Science.gov (United States)

    Joswig, Holger; Epprecht, Lorenz; Valmaggia, Christophe; Leschka, Sebastian; Hildebrandt, Gerhard; Fournier, Jean-Yves; Stienen, Martin Nikolaus

    2016-06-01

    A large number of reports have not been able to clarify the pathophysiology of Terson syndrome (TS) in aneurysmal subarachnoid hemorrhage (aSAH). Prospective single-center study on aSAH patients. Fundoscopic and radiological signs of TS were assessed. The opening intracranial pressure (ICP) in patients who required a ventriculostomy was recorded with a manometer. Six out of 36 included patients had TS (16.7 %), which was associated with unfavorable admission scores. Twenty-nine patients (80.5 %) required ventriculostomy; TS was associated with higher ICP (median, 40 vs. 15 cm cmH2O, p = .003); all patients with TS had pathological ICP values of >20 cmH2O. Patients with a ruptured aneurysm of the anterior cerebral artery complex were ten times as likely to suffer from TS (OR 10.0, 95 % CI 1.03-97.50). Detection of TS on CT had a sensitivity of 50 %, a specificity of 98.4 %, a positive predictive value of 83.3 %, and a negative predictive value of 92.4 %. Mortality was 45 times as high in patients with TS (OR 45.0, 95 % CI 3.86-524.7) and neurologic morbidity up until 3 months post-aSAH was significantly higher in patients with TS (mRS 4-6; 100 vs. 17 %; p = .001). Our findings demonstrate an association between raised ICP and the incidence of TS. TS should be ruled out in aSAH patients presenting comatose or with raised ICP to ensure upfront ophthalmological follow-up. In alert patients without visual complaints and a TS-negative CT scan, the likelihood for the presence of TS is very low.

  4. Periprocedural safety of aneurysm embolization with the Medina Coil System: the early human experience.

    Science.gov (United States)

    Turk, Aquilla S; Maia, Orlando; Ferreira, Christian Candido; Freitas, Diogo; Mocco, J; Hanel, Ricardo

    2016-02-01

    Intracranial saccular aneurysms, if untreated, carry a high risk of morbidity and mortality from intracranial bleeding. Embolization coils are the most common treatment. We describe the periprocedural safety and performance of the initial human experience with the next generation Medina Coil System. The Medina Coil System is a layered three-dimensional coil made from a radiopaque, shape set core wire, and shape memory alloy outer coil filaments. Nine aneurysms in five patients were selected for treatment with the Medina Coil System. Nine aneurysms in five patients, ranging from 5 to 17 mm in size in various locations, were treated with the Medina Coil System. No procedural or periprocedural complications were encountered. Procedure times, number of coils used to treat the aneurysm, and use of adjunctive devices were much less than anticipated if conventional coil technology had been used. The Medina Coil System is a next generation coil that combines all of the familiar and expected procedural safety and technique concepts associated with conventional coils. We found improved circumferential aneurysm filling, which may lead to improved long term outcomes, with fewer devices and faster operating times. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. Genome-wide association study identifies a sequence variant within the DAB2IP gene conferring susceptibility to abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Gretarsdottir, Solveig; Baas, Annette F; Thorleifsson, Gudmar

    2010-01-01

    to associate with AAA, with an odds ratio (OR) of 1.21 and P = 4.6 x 10(-10). In tests for association with other vascular diseases, we found that rs7025486[A] is associated with early onset myocardial infarction (OR = 1.18, P = 3.1 x 10(-5)), peripheral arterial disease (OR = 1.14, P = 3.9 x 10......(-5)) and pulmonary embolism (OR = 1.20, P = 0.00030), but not with intracranial aneurysm or ischemic stroke. No association was observed between rs7025486[A] and common risk factors for arterial and venous diseases-that is, smoking, lipid levels, obesity, type 2 diabetes and hypertension. Rs7025486 is located within...

  6. Outcome of intracranial aneurysm surgery: single center experience

    Directory of Open Access Journals (Sweden)

    Murat Ulutas

    2016-12-01

    Conclusion: Multiple aneurysms, poor grade and intracerebral hematomas are poor prognostic factors. The patients who have subarachnoid hemorrhage should be monitored by an experienced team of neurosurgery and intensive care and should be operated on as soon as possible because of rehemorrhage risk. The surgical clipping as a gold standard is still an affective and successful method. [Cukurova Med J 2016; 41(4.000: 732-743

  7. Hemodynamic and morphological characteristics of unruptured posterior communicating artery aneurysms with oculomotor nerve palsy.

    Science.gov (United States)

    Lv, Nan; Yu, Ying; Xu, Jinyu; Karmonik, Christof; Liu, Jianmin; Huang, Qinghai

    2016-08-01

    OBJECT Unruptured posterior communicating artery (PCoA) aneurysms with oculomotor nerve palsy (ONP) have a very high risk of rupture. This study investigated the hemodynamic and morphological characteristics of intracranial aneurysms with high rupture risk by analyzing PCoA aneurysms with ONP. METHODS Fourteen unruptured PCoA aneurysms with ONP, 33 ruptured PCoA aneurysms, and 21 asymptomatic unruptured PCoA aneurysms were included in this study. The clinical, morphological, and hemodynamic characteristics were compared among the different groups. RESULTS The clinical characteristics did not differ among the 3 groups (p > 0.05), whereas the morphological and hemodynamic analyses showed that size, aspect ratio, size ratio, undulation index, nonsphericity index, ellipticity index, normalized wall shear stress (WSS), and percentage of low WSS area differed significantly (p PCoA aneurysms with ONP demonstrated a distinctive morphological-hemodynamic pattern that was significantly different compared with asymptomatic unruptured PCoA aneurysms and was similar to ruptured PCoA aneurysms. The larger size, more irregular shape, and lower WSS might be related to the high rupture risk of PCoA aneurysms.

  8. A new experimental carotid siphon aneurysm model in canine based on the MR angiography and rapid prototyping technology

    International Nuclear Information System (INIS)

    Xie Jian; Li Minghua; Tan Huaqiao; Zhu Yueqi; Hu Dingjun; Qiao Ruihua; Fan Chunhua

    2009-01-01

    Objective: The aim of the experiment is to make an intracranial aneurysm model in canine. Methods: A digital tube was made based on raw magnetic resonance images of the human intracranial carotid artery. Then 6 tubes were made in the 3D rapid prototyping machine and coated with silicone. Finally we isolated the common carotid arteries of 6 canines and made them go through the tubes and anastomosed them end-to-side to get the aneurysm model. Six stents were implanted after one week. Results: Six aneurysm models were successfully made in canines. The parent artery had similar geometry of the human carotid siphon. All the aneurysms and parent arteries were patent in one week's follow-up. One canine died of excessive anesthesia after stenting. Two vascular models kept patent in one month without stenosis. The other 3 had some stenosis on the bends of the vessel. Conclusions: The aneurysm model in the experiment has high flexibility and reliability. The model provides an effective tool for research and testing neurovascular devices. It's also a useful device to train the neuroradiologists and interventional physicians. (authors)

  9. Intracranial metastases: spectrum of MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Kyoung; Lee, Eun Ja; Lee, Yong Seok [Department of Radiology, Dongguk University Ilsan Hospital, Goyang-shi (Korea, Republic of)], E-mail: ejl1048@hanmail.net; Kim, Mi Sung; Park, No Hyuck [Department of Radiology, Kwandong University, College of Medicine, Myongji Hospital, Goyang-shi (Korea, Republic of); Park, Hee-Jin [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); II, Sung Park [Department of Diagnostic Radiology, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)

    2012-12-15

    Intracranial metastatic lesions arise through a number of routes. Therefore, they can involve any part of the central nervous system and their imaging appearances vary. Magnetic resonance imaging (MRI) plays a key role in lesion detection, lesion delineation, and differentiation of metastases from other intracranial disease processes. This article is a reasoned pictorial review illustrating the many faces of intracranial metastatic lesions based on the location - intra-axial metastases, calvarial metastases, dural metastases, leptomeningeal metastases, secondary invasion of the meninges by metastatic disease involving the calvarium and skull base, direct or perineural intracranial extension of head and neck neoplasm, and other unusual manifestations of intracranial metastases. We also review the role of advanced MRI to distinguish metastases from high-grade gliomas, tumor-mimicking lesions such as brain abscesses, and delayed post-radiation changes in radiosurgically treated patients.

  10. Endo-luminal grafting for treatment of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Fu Weiguo; Wang Yuqi; Chen Fuzhen; Ye Jianrong; Wang Jianhua; Yan Zhiping; Cheng Jiemin

    2000-01-01

    Objective: To evaluate the preliminary clinical results of endovascular procedures for abdominal aortic aneurysms (AAA) in a prospective study. Methods: Six patients (average age 70 years, range 56 to 78) with infrarenal AAA were enrolled in Shanghai Zhongshan hospital from February 1998 to February 1999. Computed tomography and angiography were done in every patient for measurement of the length, diameter, and angulation of the proximal and distal AAA necks, aneurysm sac, and common and external iliac arteries. The average diameter of the aneurysm was 6.3 cm (range 4.6 cm to 8.0 cm). The mean proximal neck diameter was 2.0 cm (range 1.8 cm to 2.2 cm) and proximal neck length was 3.0 cm (range 2.5 cm to 3.5 cm). All patients were treated with the endo-luminal grafting for exclusion of AAA. Results: Two tubular and 4 bifurcated endo-grafts were used. All endo-graft procedures were completed successfully. One patient died of renal failure 72 hours after the procedure because of the prolonged operative time and excessive contrast medium. Aortography after the procedure showed the AAA were excluded by endo-graft and no endo-leak in the proximal or distal connections was detected. The patients could take meal and were ambulatory on the first and second postoperative day, respectively. Clinical success (aneurysm exclusion with no death or endo-leak) at 30 days was 83.3%. In the 24 months follow-up in 5 cases, no migration, endo-leak, and increasing aneurysm size were detected with spiral CT or color Duplex ultrasound. Conclusion: Based on initial results and a short term mean follow-up period of 24 months, the endovascular treatment of AAA with stent-graft system is feasible and safe. Further study will be required to observe the long term result in the exclusion of AAA

  11. Subarachnoid hemorrhage due to ruptured intracranial aneurysm following posterior reversible encephalopathy syndrome

    Directory of Open Access Journals (Sweden)

    Takamasa Nanba

    2016-01-01

    Full Text Available Although posterior reversible encephalopathy syndrome (PRES is rarely associated with subarachnoid hemorrhage, to our knowledge, rupture of a concomitant cerebral aneurysm following PRES has not been reported. We describe a patient with atypical PRES involving the brainstem, thalamus, and periventricular white matter without cortical or subcortical edema of the parietooccipital lobe on magnetic resonance imaging, with rupture of a concomitant cerebral aneurysm. Preexisting extremely high blood pressure may trigger atypical PRES, and failure to lower blood pressure may lead to a concomitant aneurysm rupture. In the future treatment of hypertensive urgency with a recurrence of symptoms and mean arterial blood pressure >150 mmHg, it is advisable to immediately hospitalize the patient for aggressive blood pressure management, especially if PRES is suspected based on clinical and radiological features.

  12. Interobserver variability in the assessment of aneurysm occlusion with the WEB aneurysm embolization system.

    Science.gov (United States)

    Fiorella, David; Arthur, Adam; Byrne, James; Pierot, Laurent; Molyneux, Andy; Duckwiler, Gary; McCarthy, Thomas; Strother, Charles

    2015-08-01

    The WEB (WEB aneurysm embolization system, Sequent Medical, Aliso Viejo, California, USA) is a self-expanding, nitinol, mesh device designed to achieve aneurysm occlusion after endosaccular deployment. The WEB Occlusion Scale (WOS) is a standardized angiographic assessment scale for reporting aneurysm occlusion achieved with intrasaccular mesh implants. This study was performed to assess the interobserver variability of the WOS. Seven experienced neurovascular specialists were trained to apply the WOS. These physicians independently reviewed angiographic image sets from 30 patients treated with the WEB under blinded conditions. No additional clinical information was provided. Raters graded each image according to the WOS (complete occlusion, residual neck or residual aneurysm). Final statistics were calculated using the dichotomous outcomes of complete occlusion or incomplete occlusion. The interobserver agreement was measured by the generalized κ statistic. In this series of 30 test case aneurysms, observers rated 12-17 as completely occluded, 3-9 as nearly completely occluded, and 9-11 as demonstrating residual aneurysm filling. Agreement was perfect across all seven observers for the presence or absence of complete occlusion in 22 of 30 cases. Overall, interobserver agreement was substantial (κ statistic 0.779 with a 95% CI of 0.700 to 0.857). The WOS allows a consistent means of reporting angiographic occlusion for aneurysms treated with the WEB device. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. An investigation of cerebral magnetic resonance angiography (MRA). Part 8: diagnostic ability of cerebral aneurysms with MRA using 1.5 T MRI

    International Nuclear Information System (INIS)

    Ohue, Shiro; Kusunoki, Katsusuke; Kohno, Kanehisa

    1998-01-01

    The ability of MR angiography (MRA) to detect intracranial aneurysms was assessed. Seventy-eight patients, including 21 cases of intracranial aneurysms, underwent three-dimensional time-of-flight (3D TOF) MRA using a 1.5 T MRI system. MRA images were evaluated using maximum intensity projection (MIP) images only, MIP+selective MIP images, and MIP+selective MIP+original images by ten neurosurgeons and neuroradiologists. By receiver operating characteristic (ROC) analysis of the ability to detect the 21 patients with aneurysms, the sensitivity of MIP images was 74±8% (mean±S.D.) while the specificity was 80%. Of 26 aneurysms, the sensitivity of MIP images was 64±9% (mean±S.D.). Although the sensitivity for aneurysms 5 mm or larger, or located at middle cerebral arteries was over 85%, the sensitivity for aneurysms smaller than 5 mm or located at internal carotid arteries was less than 50%. The evaluation of MRA adding selective MIP and original images to MIP images improved the sensitivity in detecting aneurysms and decreased the number of false positive cases. These data indicate that MRA is a useful technique for detecting aneurysms 5 mm or larger, and those located at the middle cerebral arteries. However, by MRA, it remains difficult to detect aneurysms smaller than 5 mm and those located at the internal carotid arteries. (author)

  14. The result of surgical treatment in patients with cerebral aneurysms in Maharaj Nakorn Chiang Mai Hospital: a report of 225 cases.

    Science.gov (United States)

    Watcharasaksilp, Wanarak; Limpastan, Kriengsak; Norasathada, Tanya; Vaniyapong, Tanat

    2013-07-01

    Evaluate the result of intracranial aneurysm surgery in Maharaj Nakorn Chiang Mai Hospital. A retrospective study ofpatients who underwent surgery for intracranial aneurysms between 2003 and 2007. The patients'age, gender, signs and symptoms, CT brain findings, Subarachnoid hemorrhage (SAH), World Federation of Neurosurgical Society grading (WFNS), and aneurysm location were studied and correlated with outcome after surgery. Two hundred twenty five patients ofintracranial aneurysm were operated on between 2003 and 2007. Two hundred nine patients (92%) had anterior circulation aneurysms and 18 (8%) had posterior circulation aneurysms. The outcome, as evaluated by Glasgow Outcome Scale (GOS), showed good recovery and moderate disability patients (142, 62.9%) were classified as favorable outcome group whereas patients with severe disability, vegetative state, and dead (83, 36.9%) were classified as unfavorable outcome. According to WFNS grading, the patients with unruptured aneurysm and WFNS grade 1-2 had favorable outcome in 116 patients (78.37%) and unfavorable outcome in 32 patients (21.62%). Whereas the patients with WFNS grade 3-5 had favorable outcome in 32 patients (33.76%) and unfavorable outcome in 51 patients (66.23%). This study of 225 cases revealed 142 cases with favorable outcome and 83 cases with unfavorable outcome. Factors that affected the outcome were WFNS grading and age.

  15. Methodology for Computational Fluid Dynamic Validation for Medical Use: Application to Intracranial Aneurysm.

    Science.gov (United States)

    Paliwal, Nikhil; Damiano, Robert J; Varble, Nicole A; Tutino, Vincent M; Dou, Zhongwang; Siddiqui, Adnan H; Meng, Hui

    2017-12-01

    Computational fluid dynamics (CFD) is a promising tool to aid in clinical diagnoses of cardiovascular diseases. However, it uses assumptions that simplify the complexities of the real cardiovascular flow. Due to high-stakes in the clinical setting, it is critical to calculate the effect of these assumptions in the CFD simulation results. However, existing CFD validation approaches do not quantify error in the simulation results due to the CFD solver's modeling assumptions. Instead, they directly compare CFD simulation results against validation data. Thus, to quantify the accuracy of a CFD solver, we developed a validation methodology that calculates the CFD model error (arising from modeling assumptions). Our methodology identifies independent error sources in CFD and validation experiments, and calculates the model error by parsing out other sources of error inherent in simulation and experiments. To demonstrate the method, we simulated the flow field of a patient-specific intracranial aneurysm (IA) in the commercial CFD software star-ccm+. Particle image velocimetry (PIV) provided validation datasets for the flow field on two orthogonal planes. The average model error in the star-ccm+ solver was 5.63 ± 5.49% along the intersecting validation line of the orthogonal planes. Furthermore, we demonstrated that our validation method is superior to existing validation approaches by applying three representative existing validation techniques to our CFD and experimental dataset, and comparing the validation results. Our validation methodology offers a streamlined workflow to extract the "true" accuracy of a CFD solver.

  16. Preoperative simulation for the planning of microsurgical clipping of intracranial aneurysms.

    Science.gov (United States)

    Marinho, Paulo; Vermandel, Maximilien; Bourgeois, Philippe; Lejeune, Jean-Paul; Mordon, Serge; Thines, Laurent

    2014-12-01

    The safety and success of intracranial aneurysm (IA) surgery could be improved through the dedicated application of simulation covering the procedure from the 3-dimensional (3D) description of the surgical scene to the visual representation of the clip application. We aimed in this study to validate the technical feasibility and clinical relevance of such a protocol. All patients preoperatively underwent 3D magnetic resonance imaging and 3D computed tomography angiography to build 3D reconstructions of the brain, cerebral arteries, and surrounding cranial bone. These 3D models were segmented and merged using Osirix, a DICOM image processing application. This provided the surgical scene that was subsequently imported into Blender, a modeling platform for 3D animation. Digitized clips and appliers could then be manipulated in the virtual operative environment, allowing the visual simulation of clipping. This simulation protocol was assessed in a series of 10 IAs by 2 neurosurgeons. The protocol was feasible in all patients. The visual similarity between the surgical scene and the operative view was excellent in 100% of the cases, and the identification of the vascular structures was accurate in 90% of the cases. The neurosurgeons found the simulation helpful for planning the surgical approach (ie, the bone flap, cisternal opening, and arterial tree exposure) in 100% of the cases. The correct number of final clip(s) needed was predicted from the simulation in 90% of the cases. The preoperatively expected characteristics of the optimal clip(s) (ie, their number, shape, size, and orientation) were validated during surgery in 80% of the cases. This study confirmed that visual simulation of IA clipping based on the processing of high-resolution 3D imaging can be effective. This is a new and important step toward the development of a more sophisticated integrated simulation platform dedicated to cerebrovascular surgery.

  17. Shared and Distinct Rupture Discriminants of Small and Large Intracranial Aneurysms.

    Science.gov (United States)

    Varble, Nicole; Tutino, Vincent M; Yu, Jihnhee; Sonig, Ashish; Siddiqui, Adnan H; Davies, Jason M; Meng, Hui

    2018-04-01

    Many ruptured intracranial aneurysms (IAs) are small. Clinical presentations suggest that small and large IAs could have different phenotypes. It is unknown if small and large IAs have different characteristics that discriminate rupture. We analyzed morphological, hemodynamic, and clinical parameters of 413 retrospectively collected IAs (training cohort; 102 ruptured IAs). Hierarchal cluster analysis was performed to determine a size cutoff to dichotomize the IA population into small and large IAs. We applied multivariate logistic regression to build rupture discrimination models for small IAs, large IAs, and an aggregation of all IAs. We validated the ability of these 3 models to predict rupture status in a second, independently collected cohort of 129 IAs (testing cohort; 14 ruptured IAs). Hierarchal cluster analysis in the training cohort confirmed that small and large IAs are best separated at 5 mm based on morphological and hemodynamic features (area under the curve=0.81). For small IAs (IAs (area under the curve=0.84; 95% confidence interval, 0.78-0.88), whereas for large IAs (≥5 mm), the model included undulation index, low wall shear stress, previous subarachnoid hemorrhage, and IA location (area under the curve=0.87; 95% confidence interval, 0.82-0.93). The model for the aggregated training cohort retained all the parameters in the size-dichotomized models. Results in the testing cohort showed that the size-dichotomized rupture discrimination model had higher sensitivity (64% versus 29%) and accuracy (77% versus 74%), marginally higher area under the curve (0.75; 95% confidence interval, 0.61-0.88 versus 0.67; 95% confidence interval, 0.52-0.82), and similar specificity (78% versus 80%) compared with the aggregate-based model. Small (IAs have different hemodynamic and clinical, but not morphological, rupture discriminants. Size-dichotomized rupture discrimination models performed better than the aggregate model. © 2018 American Heart Association, Inc.

  18. Transcatheter Embolization of a Renal Artery Aneurysm Using Ethylene Vinyl Alcohol Copolymer

    International Nuclear Information System (INIS)

    Rautio, Riitta; Haapanen, Arto

    2007-01-01

    Our aim was to treat a clinically silent renal artery aneurysm. The patient was a 76-year-old man with elevated prostate-specific antigen and prostata biopsies with a gradus II-III adenocarcinoma who was incidentally found to have an aneurysm in his right renal artery. We performed a successful transcatheter embolization of the aneurysm using ethylene vinyl alcohol copolymer (Onyx). To avoid migration of the liquid material into the parent artery, a balloon was inflated in the orifice of the neck of the aneurysm while the liquid was injected. Five-month follow-up computed tomography (CT) imaging confirmed total occlusion of the aneurysm

  19. Assessment of the signal intensity distribution pattern within the unruptured cerebral aneurysms using color-coded 3D MR angiography

    International Nuclear Information System (INIS)

    Satoh, Toru; Omi, Megumi; Ohsako, Chika

    2005-01-01

    To evaluate the interaction between the MR signal intensity distribution pattern and bleb formation/deformation of the aneurysmal dome, fifty cases of the unruptured cerebral aneurysms were investigated with the color-coded 3D MR angiography. Patterns were categorized into central-type, neck-type and peripheral-type according to the distribution of MR signals with low-, moderate- and high signal intensity areas. Imaging analysis revealed the significant relationship (P<0.02) of the peripheral-type aneurysms to the bleb formation and deformation of the dome, compared with those of central- and neck-type. Additionally, peripheral-type signal intensity distribution pattern was shown with aneurysms harboring relatively large dome size and lateral-type growth including internal carotid aneurysms. Prospective analysis of intraaneurysmal flow pattern with the color-coded 3D MR angiography may provide patient-specific analysis of intraaneurysmal flow status in relation to the morphological change of the corresponding aneurysmal dome in the management of unruptured cerebral aneurysms. (author)

  20. Subtemporal approach to basilar tip aneurysm with division of posterior communicating artery: Technical note

    Directory of Open Access Journals (Sweden)

    Shunsuke Kakino

    2008-08-01

    Full Text Available Shunsuke Kakino, Kuniaki Ogasawara, Yoshitaka Kubo, Hideaki Nishimoto, Akira OgawaDepartment of Neurosurgery, Iwate Medical University School of Medicine, Morioka, Iwate, JapanAbstract: The subtemporal approach with division of the posterior communicating artery (PcomA is described for treating aneurysms of the basilar tip. When the ipsilateral posterior cerebral artery (PCA interferes with visibility and manipulation around the aneurysm neck and the artery is tethered by the PcomA and not mobilized, the PcomA can be divided near the junction with the PCA. The procedure permits PCA mobilization and exposes the neck of the aneurysm. We applied this procedure to a patient with a ruptured aneurysm of the basilar tip. The postoperative course was uneventful except for transient left oculomotor nerve palsy. Postoperative cerebral angiography and magnetic resonance imaging confirmed the respective disappearance of the aneurysm and no new ischemic lesions. The subtemporal approach allows safer and easier division of the PcomA near the junction to the PCA compared with the pterional approach, and the present procedure is more suitable for the subtemporal approach.Keywords: basilar tip aneurysm, subtemporal approach, posterior communicating artery