WorldWideScience

Sample records for intracranial stereotactic radiosurgery

  1. Stereotactic Radiosurgery for Intracranial Tumors : Early Experience with Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Chang Ok; Chung, Sang Sup; Chu, Sung Sil; Kim, Young Soo; Yoon, Do Heum; Kim, Sun Ho; Loh, John Juhn; Kim, Gwi Eon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1992-06-15

    Between August 1988 and December 1991, 24 patients with intracranial tumors were treated with stereotactic radiosurgery(RS) using a 10 MV linear accelerator at Severance Hospital, Yonsei University College of Medicine. There were 5 meningiomas, 3 craniopharyngiomas, 9 glial tumors, 2 solitary metastases, 2 acoustic neurinomas, 2 pineal tumors, and 1 non-Hodgkin Iymphoma. Ten patients were treated as primary treatment after diagnosis with stereotactic biopsy or neuroimaging study. Nine patients underwent RS for post-op. residual tumors and three patients as a salvage treatment for recurrence after external irradiation. Two patients received RS as a boost followed by fractionated conventional radiotherapy. Among sixteen patients who were followed more than 6 months with neuroimage, seven patients (2 meningiomas, 4 benign glial tumors, one non-Hodgkin lymphoma) showed complete response on neuroimage after RS and nine patients showed decreased tumor size. There was no acute treatment related side reaction. Late complications include three patients with symptomatic peritumoral braid edema and one craniopharyngioma with optic chiasmal injury. Through this early experience, we conclude that stereotactically directed single high doses of irradiation to the small intracranial tumors is effective for tumor control. However, in order to define the role of radiosurgery in the management of intracranial tumors, we should get the long-term results available to demonstrate the benefits versus potential complications of this therapeutic modality.

  2. The history of stereotactic radiosurgery and radiotherapy.

    Science.gov (United States)

    Lasak, John M; Gorecki, John P

    2009-08-01

    Stereotactic neurosurgery originated from the pioneering work of Horsley and Clarke, who developed a stereotactic apparatus to study the monkey brain in 1908. Spiegel and Wycis applied this technology to the human brain in 1947, which ultimately lead to the development of multiple stereotactic neurosurgical devices during the 1950s. It was Lars Leksell of Sweden, however, who envisioned stereotactic radiosurgery. Leksell developed the gamma knife to treat intracranial lesions in a noninvasive fashion. His work stimulated worldwide interest and created the field of stereotactic radiosurgery.

  3. Clinical-radiological evaluation of sequelae of stereotactic radiosurgery for intracranial arteriovenous malformations

    International Nuclear Information System (INIS)

    Levy, R.P.; Fabrikant, J.I.; Frankel, K.A.; Phillips, M.H.; Steinberg, G.K.; Marks, M.P.; DeLaPaz, R.L.; Chuang, F.Y.S.

    1989-12-01

    Stereotactic heavy-charged-particle Bragg peak radiosurgery has been used to treat 322 patients with surgically-inaccessible intracranial vascular malformations. (The clinical results of this method for the treatment of angiographically demonstrable arteriovenous malformations (AVMs) and angiographically occult vascular malformations (AOVMs) of the brain are described in separate reports of this symposium). The great majority of patients have had an uneventful post-treatment course with satisfactory health outcomes. However, several categories of delayed sequelae of stereotactic radiosurgery have been identified, involving the vascular structures essential for the integrity of the brain tissue and the brain parenchyma directly. These categories reflect both reaction to injury and to alterations in regional hemodynamic status, and include vasogenic edema, occlusion of functional vasculature, radiation necrosis, and local or remote effects on cerebral arterial aneurysms. 10 refs., 7 figs., 1 tab

  4. Clinical-radiological evaluation of sequelae of stereotactic radiosurgery for intracranial arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R.P.; Fabrikant, J.I.; Frankel, K.A.; Phillips, M.H.; Steinberg, G.K.; Marks, M.P.; DeLaPaz, R.L.; Chuang, F.Y.S.

    1989-12-01

    Stereotactic heavy-charged-particle Bragg peak radiosurgery has been used to treat 322 patients with surgically-inaccessible intracranial vascular malformations. (The clinical results of this method for the treatment of angiographically demonstrable arteriovenous malformations (AVMs) and angiographically occult vascular malformations (AOVMs) of the brain are described in separate reports of this symposium). The great majority of patients have had an uneventful post-treatment course with satisfactory health outcomes. However, several categories of delayed sequelae of stereotactic radiosurgery have been identified, involving the vascular structures essential for the integrity of the brain tissue and the brain parenchyma directly. These categories reflect both reaction to injury and to alterations in regional hemodynamic status, and include vasogenic edema, occlusion of functional vasculature, radiation necrosis, and local or remote effects on cerebral arterial aneurysms. 10 refs., 7 figs., 1 tab.

  5. Intracranial osteosarcoma after radiosurgery. Case report

    International Nuclear Information System (INIS)

    Sanno, Naoko; Hayashi, Shinkichi; Shimura, Toshiro; Maeda, Shotaro; Teramoto, Akira

    2004-01-01

    A 56-year-old woman presented with an intracranial osteosarcoma at the site of previous radiosurgery, manifesting as sudden onset of headache and left hemiparesis with aphasia. She had a previous history of stereotactic radiosurgery for an intracranial tumor under a diagnosis of falx meningioma. Computed tomography showed intratumoral and peritumoral hemorrhage at the right parietofrontal region. Gross total resection of the tumor with hematoma was performed. The histological diagnosis was osteosarcoma. Sarcomatous change is a rare complication of radiotherapy. This case illustrates that osteosarcoma may develop years after radiosurgery for benign brain neoplasm. (author)

  6. Stereotactic helium-ion radiosurgery for the treatment of intracranial arteriovenous malformations

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Levy, R.P.; Frankel, K.A.; Phillips, M.H.; Lyman, J.T.; Chuang, F.Y.S.; Steinberg, G.K.; Marks, M.P.

    1989-12-01

    One of the more challenging problems of vascular neurosurgery is the management of surgically-inaccessible arteriovenous malformations (AVMs) of the brain. At Lawrence Berkeley Laboratory, we have developed the method of stereotactic heavy-charged-particle (helium-ion) Bragg peak radiosurgery for treatment of inoperable intracranial AVMs in over 300 patients since 1980 [Fabrikant et al. 1989, Fabrikant et al. 1985, Levy et al. 1989]. This report describes patient selection, treatment method, clinical and neuroradiologic results and complications encountered. 4 refs

  7. Factors influencing local control and survival for patients undergoing stereotactic radiosurgery for intracranial metastases

    International Nuclear Information System (INIS)

    Suh, John H.; Barnett, Gene H.; Sohn, Jason W.; Fernandez-Vicioso, Eduardo; Kupelian, Patrick A.

    1996-01-01

    PURPOSE: To identify factors affecting local control and survival for patients undergoing stereotactic radiosurgery for intracranial metastases. MATERIALS AND METHODS: From 3/90-10/95, 99 patients (median age 58, range 29-83; 44 women, 55 men) with asymptomatic or mildly symptomatic intracranial metastases measuring < 4 cm in diameter and ≥ 1 cm from optic chiasm and Karnofsky Performance Status (KPS) ≥ 70 underwent modified linear accelerator-based stereotactic radiosurgery (SRS). Patients characteristics included 20 with recurrent disease, 66 with solitary lesions, and 42 with systemic disease. Forty six patients underwent surgical resection prior to SRS (16 biopsy, 3 subtotal resection (STR), and 21 gross total resection (GTR)). Eighty of 99 patients underwent whole brain radiation treatments (median 4005 cGy/15 fx, range 2200-6000 cGy). A total of 154 lesions were treated with 143 being evaluable on follow-up CT or MRI scans. Radiosurgery parameters (median) were the following: volume 2.8 cc (range 0.1-38 cc) and a peripheral dose of 1700 cGy (range 500-2400 cGy) with normalization to the 80% line (range 50-90%). Survival was measured from the date of SRS. Local control was defined as stabilization or decrease in size of the intracranial lesion(s). RESULTS: The following factors were analyzed with respect to local control and survival: 1) solitary vs. multiple lesions, 2) Age < or ≥ 60, 3) sex, 4) radiosensitive vs. radioresistant (renal cell and melanoma) histologies, 5) recurrent vs. newly diagnosed lesions, 6) KPS (70-80 vs. 90-100), 7) extent of surgery (biopsy vs. STR/GTR), 8) use of whole brain radiation treatments, 9) absence or presence of systemic disease, 10) dose (< or ≥ 1500 cGy) and 11) volume (< or ≥ 3 cc). On univariate analysis, survival was significantly influenced by female sex, presence of solitary lesion, absence of systemic disease, and extent of surgery. On multivariate analysis, female sex (p=0.0037), absence of systemic disease

  8. Stereotactic intracranial radiotherapy: Dose prescription

    International Nuclear Information System (INIS)

    Schlienger, M.; Lartigau, E.; Nataf, F.; Mornex, F.; Latorzeff, I.; Lisbona, A.; Mahe, M.

    2012-01-01

    The aim of this article was the study of the successive steps permitting the prescription of dose in stereotactic intracranial radiotherapy, which includes radiosurgery and fractionated stereotactic radiotherapy. The successive steps studied are: the choice of stereotactic intracranial radiotherapy among the therapeutic options, based on curative or palliative treatment intent, then the selection of lesions according to size/volume, pathological type and their number permitting the choice between radiosurgery or fractionated stereotactic radiotherapy, which have the same methodological basis. Clinical experience has determined the level of dose to treat the lesions and limit the irradiation of healthy adjacent tissues and organs at risk structures. The last step is the optimization of the different parameters to obtain a safe compromise between the lesion dose and healthy adjacent structures. Study of dose-volume histograms, coverage indices and 3D imaging permit the optimization of irradiation. For lesions close to or included in a critical area, the prescribed dose is planned using the inverse planing method. Implementation of the successively described steps is mandatory to insure the prescription of an optimized dose. The whole procedure is based on the delineation of the lesion and adjacent healthy tissues. There are sometimes difficulties to assess the delineation and the volume of the target, however improvement of local control rates and reduction of secondary effects are the proof that the totality of the successive procedures are progressively improved. In practice, stereotactic intracranial radiotherapy is a continually improved treatment method, which constantly benefits from improvements in the choice of indications, imaging, techniques of irradiation, planing/optimization methodology and irradiation technique and from data collected from prolonged follow-up. (authors)

  9. The Physician Tendency in Stereotactic Radiosurgery Dose Prescription in Benign Intracranial Tumor at dr. Cipto Mangunkusumo National Hospital, Jakarta

    Directory of Open Access Journals (Sweden)

    Henry Kodrat

    2016-09-01

    Full Text Available Stereotactic radiosurgery (SRS is one of the treatment modalities for benign intra-cranial tumor, especiallyfor the tumor located next to the critical neural structure. The prescribed dose for radiosurgery depends onthe maximal tumor diameter and surrounding normal tissue tolerance dose. This cross sectional study wasconducted to evaluate the physician’s tendency in radiosurgery dose prescription. We observed treatmentplanning data of 32 patients with benign intra-cranial tumor, which had been treated with SRS at Dr. CiptoMangunkusumo National Hospital in 2009-2010. The peripheral dose, organ at risk (OAR dose limitiationand maximum tumor diameter were recorded. We compared our SRS dose with dose limitation, whichallowed safer dosing based on maximal tumor diameter perspective and the nearest OAR dose constraint.From maximal tumor diameter perspective, we prescribed mean±SD radiosurgery doses, which were11.63±2.21Gy, 10.21±1.29Gy and 9.88±1.07Gy for the tumor size ≤2cm, 2.01-3cm and 3,01-4cm respectively.Our radiosurgery dose was the lowest than dose limitation based on the nearest OAR perspective, followedby maximal tumor diameter perspective. It was concluded that radiosurgery dose had the tendency to beinfluenced by surrounding healthy tissue tolerance rather than maximal tumor diameter. Keywords: stereotactic, radiosurgery, benign tumor, dose.   Kecenderungan Dokter dalam Menentukan Dosis StereotacticRadiosurgery untuk Tumor Jinak Intrakranial diRSUP Nasional dr. Cipto Mangunkusumo, Jakarta Abstrak Stereotactic radiosurgery (SRS merupakan salah satu modalitas pengobatan tumor jinak intra-kranialterutama untuk tumor yang berdekatan dengan struktur saraf penting. Penentuan dosis pada radiosurgerytergantung pada diameter tumor maksimal dan dosis toleransi jaringan sehat sekitarnya. Penelitian inidilakukan untuk mengevaluasi kecenderungan dokter dalam menentukan dosis radiosurgery. Penelitian crosssectional ini mengevaluasi data

  10. Clinical accuracy of ExacTrac intracranial frameless stereotactic system

    International Nuclear Information System (INIS)

    Ackerly, T.; Lancaster, C. M.; Geso, M.; Roxby, K. J.

    2011-01-01

    Purpose: In this paper, the authors assess the accuracy of the Brainlab ExacTrac system for frameless intracranial stereotactic treatments in clinical practice. Methods: They recorded couch angle and image fusion results (comprising lateral, longitudinal, and vertical shifts, and rotation corrections about these axes) for 109 stereotactic radiosurgery and 166 stereotactic radiotherapy patient treatments. Frameless stereotactic treatments involve iterative 6D image fusion corrections applied until the results conform to customizable pass criteria, theirs being 0.7 mm and 0.5 deg. for each axis. The planning CT slice thickness was 1.25 mm. It has been reported in the literature that the CT slices' thickness impacts the accuracy of localization to bony anatomy. The principle of invariance with respect to patient orientation was used to determine spatial accuracy. Results: The data for radiosurgery comprised 927 image pairs, of which 532 passed (pass ratio of 57.4%). The data for radiotherapy comprised 15983 image pairs, of which 10 050 passed (pass ratio of 62.9%). For stereotactic radiotherapy, the combined uncertainty of ExacTrac calibration, image fusion, and intrafraction motion was (95% confidence interval) 0.290-0.302 and 0.306-0.319 mm in the longitudinal and lateral axes, respectively. The combined uncertainty of image fusion and intrafraction motion in the anterior-posterior coordinates was 0.174-0.182 mm. For stereotactic radiosurgery, the equivalent ranges are 0.323-0.393, 0.337-0.409, and 0.231-0.281 mm. The overall spatial accuracy was 1.24 mm for stereotactic radiotherapy (SRT) and 1.35 mm for stereotactic radiosurgery (SRS). Conclusions: The ExacTrac intracranial frameless stereotactic system spatial accuracy is adequate for clinical practice, and with the same pass criteria, SRT is more accurate than SRS. They now use frameless stereotaxy exclusively at their center.

  11. Clinical results of stereotactic heavy-charged-particle radiosurgery for intracranial angiographically occult vascular malformations

    International Nuclear Information System (INIS)

    Levy, R.P.; Fabrikant, J.I.; Phillips, M.H.; Frankel, K.A.; Steinberg, G.K.; Marks, M.P.; DeLaPaz, R.L.; Chuang, F.Y.S.; Lyman, J.T.

    1989-12-01

    Angiographically occult vascular malformations (AOVMs) of the brain have been recognized for many years to cause neurologic morbidity and mortality. They generally become symptomatic due to intracranial hemorrhage, focal mass effect, seizures or headaches. The true incidence of AOVMs is unknown, but autopsy studies suggest that they are more common than high-flow angiographically demonstrable arteriovenous malformations (AVMs). We have developed stereotactic heavy-charged-particle Bragg peak radiosurgery for the treatment of inoperable intracranial vascular malformations, using the helium ion beams at the Lawrence Berkeley Laboratory 184-inch Synchrocyclotron and Bevatron. This report describes the protocol for patient selection, radiosurgical treatment planning method, clinical and neuroradiologic results and complications encountered, and discusses the strengths and limitations of the method. 10 refs., 1 fig

  12. Clinical results of stereotactic heavy-charged-particle radiosurgery for intracranial angiographically occult vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R.P.; Fabrikant, J.I.; Phillips, M.H.; Frankel, K.A.; Steinberg, G.K.; Marks, M.P.; DeLaPaz, R.L.; Chuang, F.Y.S.; Lyman, J.T.

    1989-12-01

    Angiographically occult vascular malformations (AOVMs) of the brain have been recognized for many years to cause neurologic morbidity and mortality. They generally become symptomatic due to intracranial hemorrhage, focal mass effect, seizures or headaches. The true incidence of AOVMs is unknown, but autopsy studies suggest that they are more common than high-flow angiographically demonstrable arteriovenous malformations (AVMs). We have developed stereotactic heavy-charged-particle Bragg peak radiosurgery for the treatment of inoperable intracranial vascular malformations, using the helium ion beams at the Lawrence Berkeley Laboratory 184-inch Synchrocyclotron and Bevatron. This report describes the protocol for patient selection, radiosurgical treatment planning method, clinical and neuroradiologic results and complications encountered, and discusses the strengths and limitations of the method. 10 refs., 1 fig.

  13. Intracranial radiosurgery in the Netherlands. A planning comparison of available systems with regard to physical aspects and workload.

    NARCIS (Netherlands)

    Schoonbeek, A.; Monshouwer, R.; Hanssens, P.; Raaijmakers, E.; Nowak, P.; Marijnissen, J.P.; Lagerwaard, F.J.; Cuijpers, J.P.; Vonk, E.J.; Maazen, R.W.M. van der

    2010-01-01

    Different planning and treatment systems for intracranial stereotactic radiosurgery available in the Netherlands are compared. The systems for intracranial radiosurgery include: Gamma Knife, Cyberknife, Novalis, and Tomotherapy. Electronic data of 5 patients was transferred to all participating

  14. Stereotactic radiosurgery for hemangioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Yoshimasa; Kobayashi, Tatsuya; Yamada, Yasushi; Kida, Yoshihisa; Iwakoshi, Takayasu; Yoshimoto, Masayuki [Komaki City Hospital, Aichi (Japan). Gamma Knife Center

    2001-12-01

    We evaluated the treatment results of Gamma Knife radiosurgery for intracranial hemanigioblastoma of von Hippel-Lindau syndrome or sporadic disease. Stereotactic radiosurgery was performed in 20 patients with 35 hemangioblastomas over a 9-year interval. The mean age of the patients was 48.5 years (range, 18-79 years). The volume of the tumors varied from 0.03 to 19 ml (mean, 3.0 ml), and the mean tumor margin dose was 17.8 Gy (range, 14-24 Gy). Clinical and neuroimaging follow-up was obtained 6 to 58 months (mean 26.2 months) after radiosurgery. Thirty-one (89%) of 35 tumors were controlled locally. Two tumors (6%) disappeared and 11 (31%) decreased in size during follow-up period. Eighteen (52%) remained unchanged in size. Three out of four enlarged tumors were resected surgically after radiosurgery. Another tumor was resected surgically to improve the patient's symptoms of nausea and vomiting caused by persistent perifocal edema in spite of reduced tumor volume. Only one patient, who had a tumor in the 4th ventricle arising from the brainstem, died 12 months after radiosurgery. Although the treated tumor remained stable in size, he developed aspiration pneumonia due to brainstem dysfunction caused by perifocal edema. All tumors less than 1 cm in diameter did not progress during follow-up period. For small hemangioblastomas, radiosurgery is a safe and effective option to control disease. If a large tumor is treated by radiosurgery, careful observation of the patient's neurological condition is necessary. (author)

  15. Evaluation of Image-Guided Positioning for Frameless Intracranial Radiosurgery

    International Nuclear Information System (INIS)

    Lamba, Michael; Breneman, John C.; Warnick, Ronald E.

    2009-01-01

    Purpose: The standard for target alignment and immobilization in intracranial radiosurgery is frame-based alignment and rigid immobilization using a stereotactic head ring. Recent improvements in image-guidance systems have introduced the possibility of image-guided radiosurgery with nonrigid immobilization. We present data on the alignment accuracy and patient stability of a frameless image-guided system. Methods and Materials: Isocenter alignment errors were measured for in vitro studies in an anthropomorphic phantom for both frame-based stereotactic and frameless image-guided alignment. Subsequently, in vivo studies assessed differences between frame-based and image-guided alignment in patients who underwent frame-based intracranial radiosurgery. Finally, intratreatment target stability was determined by image-guided alignment performed before and after image-guided mask immobilized radiosurgery. Results: In vitro hidden target localization errors were comparable for the framed (0.7 ± 0.5 mm) and image-guided (0.6 ± 0.2 mm) techniques. The in vivo differences in alignment were 0.9 ± 0.5 mm (anteroposterior), -0.2 ± 0.4 mm (superoinferior), and 0.3 ± 0.5 mm (lateral). For in vivo stability tests, the mean distance differed between the pre- and post-treatment positions with mask-immobilized radiosurgery by 0.5 ± 0.3 mm. Conclusion: Frame-based and image-guided alignment accuracy in vitro was comparable for the system tested. In vivo tests showed a consistent trend in the difference of alignment in the anteroposterior direction, possibly due to torque to the ring and mounting system with frame-based localization. The mask system as used appeared adequate for patient immobilization.

  16. Stereotactic radiosurgery. The role of charged particles

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R.P.; Schulte, R.W.M.; Slater, J.D.; Miller, D.W.; Slater, J.M. [Loma Linda Univ. Medical Center, CA (United States). Dept. of Radiation Medicine

    1999-08-01

    Stereotactic radiosurgery using charged-particle beams has been the subject of biomedical research and clinical development for more than 50 years. Charged particles of proton mass or greater manifest unique physical properties that can be used to place a high dose of radiation preferentially within the boundaries of a deeply located intracranial target volume. Since 1954, nearly 10 000 patients have been treated using this technique. Treated disorders include pituitary tumors, vascular malformations, primary and metastatic brain tumors, and subfoveal neovascularization. Charged-particle radiosurgery is particularly advantageous for the conformal treatment of large and/or irregularly shaped lesions, or for the treatment of lesions located in front of or adjacent to sensitive brain structures. (orig.)

  17. Stereotactic radiosurgery. The role of charged particles

    International Nuclear Information System (INIS)

    Levy, R.P.; Schulte, R.W.M.; Slater, J.D.; Miller, D.W.; Slater, J.M.

    1999-01-01

    Stereotactic radiosurgery using charged-particle beams has been the subject of biomedical research and clinical development for more than 50 years. Charged particles of proton mass or greater manifest unique physical properties that can be used to place a high dose of radiation preferentially within the boundaries of a deeply located intracranial target volume. Since 1954, nearly 10 000 patients have been treated using this technique. Treated disorders include pituitary tumors, vascular malformations, primary and metastatic brain tumors, and subfoveal neovascularization. Charged-particle radiosurgery is particularly advantageous for the conformal treatment of large and/or irregularly shaped lesions, or for the treatment of lesions located in front of or adjacent to sensitive brain structures. (orig.)

  18. Patients burden in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Kralik, G.; Fribertova, M.; Trosanova, D.; Kolarcikova, E.

    2009-01-01

    Radiosurgery is one time application of High radiation to a stereotactically defined volume. Treatment delivery involves multiple stereotactically targeted, arced fields. The goal of Radiosurgery is to deliver a high dose to target, while only a minimum dose is delivered to adjacent normal tissue that are just a few millimeters away . Stereotactic Radiosurgery on linac has been employed at St. Elisabeth Cancer Institute in Bratislava since 1993. Until July 31,2008, 1 030 subjects have been treated including patients with brain tumors, metastases, recurrent tumours, and A V malformations, using Leibinger stereotaxy collimators or Mimic MLC system on a Linac accelerator. The presentation shows dose delivery to risk organs in different indications. (authors)

  19. Stereotactic treatment. Definitions and literature overview

    International Nuclear Information System (INIS)

    Fontenla, D.P.

    2008-01-01

    The topics discussed include, among others, the following: Radiosurgery definitions; Stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT); Available uncertainties in SRS; Gamma knife; Linac-based SRS; Components of a radiosurgery system; Stereotactic hardware (brain lab); m3 linac attachment; Radiosurgery - clinical procedure; Cancer management; Rationale for SRT; Role of radiosurgery in the management of intracranial tumors; Indications for stereotactic SRS/SRT; Physical components required for SRS/SRT; Stereotactic patient set-up; Stereotactic CT scan for SRS; Physical components required for SRT: Relocatable head frame (GTC); Patient immobilization; Treatment planning system; Basic requirements for SRS dosimetry (Linac based); Stereotactic set-up QA (Linac); Stereotactic frames and QA; Beam dose measurements; Dose evaluation tools; Phantoms. (P.A.)

  20. Peritumoral Brain Edema after Stereotactic Radiosurgery for Asymptomatic Intracranial Meningiomas: Risks and Pattern of Evolution.

    Science.gov (United States)

    Hoe, Yeon; Choi, Young Jae; Kim, Jeong Hoon; Kwon, Do Hoon; Kim, Chang Jin; Cho, Young Hyun

    2015-10-01

    To investigate the risks and pattern of evolution of peritumoral brain edema (PTE) after stereotactic radiosurgery (SRS) for asymptomatic intracranial meningiomas. A retrospective study was conducted on 320 patients (median age 56 years, range 24-87 years) who underwent primary Gamma Knife radiosurgery for asymptomatic meningiomas between 1998 and 2012. The median tumor volume was 2.7 cc (range 0.2-10.5 cc) and the median follow-up was 48 months (range 24-168 months). Volumetric data sets for tumors and PTE on serial MRIs were analyzed. The edema index (EI) was defined as the ratio of the volume of PTE including tumor to the tumor volume, and the relative edema indices (rEIs) were calculated from serial EIs normalized against the baseline EI. Risk factors for PTE were analyzed using logistic regression. Newly developed or increased PTE was noted in 49 patients (15.3%), among whom it was symptomatic in 28 patients (8.8%). Tumor volume larger than 4.2 cc (pmaking on SRS for asymptomatic meningiomas of large volume (>4.2 cc), of hemispheric location, or with pre-treatment PTE. PTE usually develops within months, reaches its maximum degree until a year, and resolves within 2 years after SRS.

  1. Value of stereotactic radiosurgery in patients with multiple brain metastases

    International Nuclear Information System (INIS)

    Chen Jie; Lin Zhiguo; Li Qingguo; Shen Hong

    2002-01-01

    Objective: To analyze the prognostic factors and evaluate the effect of stereotactic radiosurgery for patients with multiple brain metastases. Methods: Comparison was made in 53 such patients treated by stereotactic radiosurgery plus radiotherapy and 53 treated by radiotherapy alone. Patients were matched-paired according to the following criteria: age, Karnofsky performance scale (KPS) before treatment, extent of systemic cancer and number of brain metastasis. Forty patients had stereotactic radiosurgery, 13 patients stereotactic fractionated radiosurgery. In the stereotactic radiosurgery group, the patients were given a mean marginal dose of 20 Gy. Methods of stereotactic fractionated radiosurgery was 4-12 Gy per fraction , twice a week to a total dose of 15-30 Gy. Whole brain radiotherapy was given immediately after stereotactic radiosurgery. For patients treated by radiotherapy alone, the entire brain was treated by 30-40 Gy in 3-4 weeks. Results: The median survival was 11.6 months in stereotactic radiosurgery plus radiotherapy and 6.7 months in radiotherapy alone. The one year survival rate and one year local control rate were 44.3%, 17.1% and 50.9%, 13. 2%. Those with KPS increased after treatment gave 1-year survivals of 69.8% and 30.2%, respectively. The validity rates in CT or MRI three months after treatment were 82.0% and 55.0%. The difference in the two groups was found to be statistically significant (P < 0.01). 23.3% of death in the stereotactic radiosurgery plus radiotherapy group was due to brain metastasis vs 51.0% in the radiotherapy alone group (P < 0.05). Complication of the two groups was similar. Conclusion: Stereotactic radiosurgery plus radiotherapy is superior to radiotherapy alone for multiple brain metastases in improving the local control and ultimate outcome

  2. Stereotactic radiosurgery using the gamma knife

    Energy Technology Data Exchange (ETDEWEB)

    Kawamoto, Shunsuke; Sasaki, Tomio; Matsutani, Masao; Takakura, Kintomo; Terahara, Atsuro (Tokyo Univ. (Japan). Faculty of Medicine)

    1992-03-01

    Since stereotactic radiosurgery using a gamma knife was developed in 1968 by Leksell, it has been used with increasing frequency in Japan. During the period from June 19, 1990 through December 20, 1991, 218 patients have been treated with stereotactic radiosurgery using a gamma knife. Of them, 116 had vascular lesions (116), including arteriovenous malformation (114), dural arteriovenous malformation (one), and cerebral aneurysm (one); and the other 102 had tumorous lesions, including acoustic neurinoma (48), meningioma (26), pituitary tumor (11), metastatic tumor (7), germ cell tumor (3), glioma (2), hemangioblastoma (2), chordoma (one), craniopharyngioma (one), and trigeminal neurinoma (one). In this article, candidates of stereotactic radiosurgery using a gamma knife are discussed, with particular attention to clinical results of the aforementioned 218 patients. (N.K.) 54 refs.

  3. Results of a Conservative Dose Plan Linear Accelerator-Based Stereotactic Radiosurgery for Pediatric Intracranial Arteriovenous Malformations.

    Science.gov (United States)

    Rajshekhar, Vedantam; Moorthy, Ranjith K; Jeyaseelan, Visalakshi; John, Subhashini; Rangad, Faith; Viswanathan, P N; Ravindran, Paul; Singh, Rabiraja

    2016-11-01

    To evaluate the obliteration rate and clinical outcome following linear accelerator (LINAC)-based stereotactic radiosurgery (SRS) for intracranial arteriovenous malformation (AVM) in pediatric patients (age ≤18 years). Factors associated with the obliteration rate and neurologic complications were studied retrospectively in pediatric patients who underwent LINAC-based SRS for AVM between June 1995 and May 2014. The study cohort comprised 36 males and 33 females, with a median age at the time of SRS of 14 years (range, 7-18 years). The mean AVM volume was 8.5 ± 8.7 cc (range, 0.6-41.8 cc). The median marginal dose of radiation delivered was 15 Gy (range, 9-20 Gy). Magnetic resonance imaging (MRI) demonstrated complete obliteration of the AVM in 44 of the 69 patients (63.8%), at a mean follow up of 27.5 months (range, 12-90 months). On subgroup analysis, 41 of the 53 AVMs of ≤14 cc in volume (77.3%) were obliterated. AVMs with a modified AVM radiosurgery score <1 had significantly shorter obliteration times from the time of SRS (P = .006). On multivariate analysis, the mean marginal dose of radiation delivered to the AVM was the sole significant predictor of obliteration (odds ratio, 1.6; 95% confidence interval, 1 to 2.4). A modest median marginal dose of 15 Gy (16 Gy in the obliterated AVM group vs. 12 Gy in the nonobliterated group) resulted in an obliteration rate of 66.7% after LINAC-based SRS for intracranial AVM, with low rate. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Evaluations of the setup discrepancy between BrainLAB 6D ExacTrac and cone-beam computed tomography used with the imaging guidance system Novalis-Tx for intracranial stereotactic radiosurgery.

    Science.gov (United States)

    Oh, Se An; Park, Jae Won; Yea, Ji Woon; Kim, Sung Kyu

    2017-01-01

    The objective of this study was to evaluate the setup discrepancy between BrainLAB 6 degree-of-freedom (6D) ExacTrac and cone-beam computed tomography (CBCT) used with the imaging guidance system Novalis Tx for intracranial stereotactic radiosurgery. We included 107 consecutive patients for whom white stereotactic head frame masks (R408; Clarity Medical Products, Newark, OH) were used to fix the head during intracranial stereotactic radiosurgery, between August 2012 and July 2016. The patients were immobilized in the same state for both the verification image using 6D ExacTrac and online 3D CBCT. In addition, after radiation treatment, registration between the computed tomography simulation images and the CBCT images was performed with offline 6D fusion in an offline review. The root-mean-square of the difference in the translational dimensions between the ExacTrac system and CBCT was <1.01 mm for online matching and <1.10 mm for offline matching. Furthermore, the root-mean-square of the difference in the rotational dimensions between the ExacTrac system and the CBCT were <0.82° for online matching and <0.95° for offline matching. It was concluded that while the discrepancies in residual setup errors between the ExacTrac 6D X-ray and the CBCT were minor, they should not be ignored.

  5. Stereotactic radiosurgery: incision less surgery

    International Nuclear Information System (INIS)

    Alvarez, Victor M.; Palma, Raul B.

    1997-01-01

    Stereotactic Radiosurgery (SRS) involves the application of focused high dose, high energy radiation to precisely (stereotactically) localized targets in the head without opening the skull for the purpose of destroying pathologic tissues like tumors, and also for producing discrete lesions for the relief of certain functional disorders. This procedure was pioneered by Lars Leksel in the 1950s and has progressively been refined with the development of more powerful computer technology and more precise and safer radiation delivery systems. The used of the Linear Accelerator (LINAC)- based radiosurgery system would be the most cost-effective and appropriate system for this treatment

  6. Linear accelerator stereotactic radiosurgery for trigeminal neuralgia.

    Science.gov (United States)

    Varela-Lema, Leonor; Lopez-Garcia, Marisa; Maceira-Rozas, Maria; Munoz-Garzon, Victor

    2015-01-01

    Stereotactic radiosurgery is accepted as an alternative for patients with refractory trigeminal neuralgia, but existing evidence is fundamentally based on the Gamma Knife, which is a specific device for intracranial neurosurgery, available in few facilities. Over the last decade it has been shown that the use of linear accelerators can achieve similar diagnostic accuracy and equivalent dose distribution. To assess the effectiveness and safety of linear-accelerator stereotactic radiosurgery for the treatment of patients with refractory trigeminal neuralgia. We carried out a systematic search of the literature in the main electronic databases (PubMed, Embase, ISI Web of Knowledge, Cochrane, Biomed Central, IBECS, IME, CRD) and reviewed grey literature. All original studies on the subject published in Spanish, French, English, and Portuguese were eligible for inclusion. The selection and critical assessment was carried out by 2 independent reviewers based on pre-defined criteria. In view of the impossibility of carrying out a pooled analysis, data were analyzed in a qualitative way. Eleven case series were included. In these, satisfactory pain relief (BIN I-IIIb or reduction in pain = 50) was achieved in 75% to 95.7% of the patients treated. The mean time to relief from pain ranged from 8.5 days to 3.8 months. The percentage of patients who presented with recurrences after one year of follow-up ranged from 5% to 28.8%. Facial swelling or hypoesthesia, mostly of a mild-moderate grade appeared in 7.5% - 51.9% of the patients. Complete anaesthesia dolorosa was registered in only study (5.3%). Cases of hearing loss (2.5%), brainstem edema (5.8%), and neurotrophic keratoplasty (3.5%) were also isolated. The results suggest that stereotactic radiosurgery with linear accelerators could constitute an effective and safe therapeutic alternative for drug-resistant trigeminal neuralgia. However, existing studies leave important doubts as to optimal treatment doses or the

  7. Linac based radiosurgery and stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Mackie, T.R.

    2008-01-01

    The following topics were discussed: Definition of stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT); Stereo market; Indications for SRS/SRT; History of linac-based SRS/SRT; Variety of systems; QA for SRS; Localization; and Imaging. (P.A.)

  8. Frame-based and frameless stereotactic radiosurgery for intracranial and extracranial tumors

    International Nuclear Information System (INIS)

    Petrovich, Z.; Cheng Yu

    2003-01-01

    During the past 10 years stereotactic frame-based radiosurgery (SRS) emerged as an important treatment modality in the management of selected intracranial lesions. More recently, frameless SRS has extended the potential of ibis treatment to include lesions virtually in any site of the body. Many thousands of patients are being treated annually with frame-based SRS limited to the cranial cavity. A total of 180,222 patients were treated to December 2001 with gamma knife (GK) and, very likely, a similar number was treated with various linear accelerator based SRS systems. Frameless SRS has been performed uncommonly until cyber knife (CK) became available. Over 3,000 patients were treated with CK in the US and Japan. This included patients treated for extracranial lesions. Treatment results in patients treated with GK at University of Southern California (USC) will be presented. From 1994 to 2002, a total of 1,126 patients received GK at USC for various indications. Since metastatic tumor constituted the largest (42.4%) diagnostic category treated, the outcome in this group is specifically discussed. The overall median survival was 9.2 months. The median survival was 8.3, 9.0, 17 and 12 months, for melanoma, lung cancer, breast cancer and renal cell carcinoma, respectively. In multivariate analysis Karnofsky's performance status (70 vs. >70), status of systemic disease (inactive vs. active), tumor histology and total intracranial tumor volume were the only important factors predictive of survival, p=0.0001. Cause of death was found to be due to CNS problems in about 25% of patients with a diagnosis other than melanoma, while it was 42% in those with melanoma. GK SRS was given on an outpatient basis and was very well tolerated by the patients. Symptomatic focal radionecrosis requiring craniotomy for its removal was noted in <5% of patients. An excellent palliative benefit was obtained in nearly all patients. The treatment was compatible with a good quality of life

  9. Dosimetric evaluation of proton stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Min, Byung Jun; Shin, Dong Ho; Yoo, Seung Hoon; Jeong, Hojin; Lee, Se Byeong

    2011-01-01

    Surgical excision, conventional external radiotherapy, and chemotherapy could prolong survival in patients with small intracranial tumors. However, surgical excision for meningiomas located in the region of the base of skull or re-resection is often difficult. Moreover, treatment is needed for patients with recurrent tumors or postoperative residual tumors. Conventional external radiotherapy is popular and has significantly increased for treating brain tumors. Stereotactic radiosurgery is an effective alternative treatment technique to microsurgical resection such as benign brain tumor or vestibular Schwannomas. In general, the dose to OAR of 3D conformal plan is lower than that of conformal arc and dynamic conformal arc plans. However, any of OARs was not reached to tolerance dose. Although mean dose of the healthy brain tissue for 3D conformal plan was slightly higher than that of arc plans, the doses of the healthy brain tissue at V10 and V20 were significantly low for dynamic conformal arc plan. The dosimetric differences were the greatest at lower doses. In contrast, 3D conformal plan was better spare at higher doses. In this study, a dosimetric evaluation of proton stereotactic radiosurgery for brain lesion tumors was using fixed and arc beams. A brass block fitted to the PTV structure was modeled for dynamic conformal collimator. Although all treatment plans offer a very good coverage of the PTV, we found that proton arc plans had significantly better conformity to the PTV than static 3D conformal plan. The V20 dose of normal brain for dynamic conformal arc therapy is dramatically reduced compare to those for other therapy techniques.

  10. A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife

    International Nuclear Information System (INIS)

    Choi, Tae Jin; Kim, Jin Hee; Kim, Ok Bae

    1996-01-01

    Purpose : To get an acute steepness of dose gradients at outside the target volume in intracranial lesion and a less limitation of beam selection avoiding the high dose at normal brain tissue, this Photon Knife Radiosurgery System was developed in order to provide the three-dimensional dose distribution through the reconstruction of CT scan and the combined stereotactic tranmultiarc beam mode based on linear accelerator photon beam. Methods and Materials : This stereotactic radiosurgery, Photon Knife based on linear accelerator photon beam was provided the non-coplanar multiarc and trans-multiarc irradiations. The stereotactic trans-multiarc beam mode can be obtained from the patient position in decubitus. This study has provided the 3-dimensional isodose curve and anatomical structures with the surface rendering technique. Results : In this study, it shows that the dose distributions of stereotactic beam mode are significantly depended on the selected couch and gantry angle in same collimator size. Practical dose distribution of combined stereotactic trans-multiarc beam has shown a more small rim thickness than that of the non-coplanar multiarc beam mode in axial, sagittal and coronal plane in our study. 3-Dimensional dose line displayed with surface rendering of irregular target shape is helpful to determine the target dose and to predict the prognosis in follow-up radiosurgery. Conclusion : 3-Dimensional dose line displayed with surface rendering of irregular target shape is essential in stereotactic radiosurgery. This combined stereotactic trans-multiarc beam has shown a less limitation of the selection couch and gantry beam angles for the target surrounding critical organs. It has shown that the dose distribution of combined trans-multiarc beam greatly depended on the couch and gantry angles. In our experiments. the absorbed dose has been decreased to 27 % /mm in maximum at the interval of 50% to 80% of isodose line

  11. A new treatment method for brain diseases. Stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Shirato, Hiroki

    1994-01-01

    This paper deals with stereotactic radiosurgery, a novel medical treatment technique for brain diseases. It is the most sophisticated modality that allows the functional preservation. Recently, CT scan and MRI scan have dramatically changed the diagnostic accuracy of tumor localization in the brain. A device named stereotactic head fixation system makes it possible to localize deep-seated brain diseases with an accuracy of 1-1.5 mm. Using multiple convergent narrow beams of high-energy X-ray, a stereotactic head frame, and a three dimensional computer graphics of CT images, patients with deep-seated nidus can be treated without any complications. Normal tissues would not receive large doses but the center of the nidus is irradiated heavily because of the convergence of X-ray beams. Thus stereotactic radiosurgery is more accurate, effective, and less toxic than conventional radiotherapy and is safer and more effective than surgery for many brain diseases. Small arteriovenous malformation in the brain, which is a fetal disease, and small acoustic neurinomas, in which surgery often causes facial nerve palsy and hearing loss, are presented as good candidates for radiosurgery. For metastatic brain tumors, stereotactic radiosurgery makes such patients free from neurological symptoms, such as difficulty in walking and speaking, in a few days. (N.K.)

  12. Stereotactic radiosurgery versus whole-brain radiotherapy after intracranial metastasis resection : A systematic review and meta-analysis

    NARCIS (Netherlands)

    Lamba, Nayan; Muskens, Ivo S; DiRisio, Aislyn C; Meijer, Louise; Briceno, Vanessa; Edrees, Heba; Aslam, Bilal; Minhas, Sadia; Verhoeff, Joost J.C.; Kleynen, Catharina E.; Smith, Timothy R; Mekary, Rania A; Broekman, Marike L.

    2017-01-01

    Background: In patients with one to three brain metastases who undergo resection, options for post-operative treatments include whole-brain radiotherapy (WBRT) or stereotactic radiosurgery (SRS) of the resection cavity. In this meta-analysis, we sought to compare the efficacy of each post-operative

  13. WE-A-304-00: Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    2015-01-01

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB

  14. WE-A-304-00: Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB.

  15. SU-F-T-212: A Comparison of Treatment Strategies for Intracranial Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Lamberton, T; Slater, J; Wroe, A

    2016-01-01

    Purpose: Stereotactic radiosurgery is an effective and noninvasive treatment for intracranial lesions that uses highly focused radiation beams in a single treatment fraction. The purpose of this study is to investigate the dosimetric differences between the treatment brain metastasis with a proton beam vs. intensity modulated radiation therapy (IMRT). Methods: Ten separate brain metastasis targets where chosen and treatment plans were created for each, using three different strategies: custom proton beam shaping devices, standardized proton beam shaping devices, and IMRT. Each plan was required to satisfy set parameters for providing adequate coverage and minimizing risk to adjacent tissues. The effectiveness of each plan was calculated by comparing the homogeneity index, conformity index, and V12 for each target using a paired one tailed T-test (α=0.05). Specific comparison of the conformity indices was also made using a subcategory containing targets with volume>1cc. Results: There was no significant difference between the homogeneity indices of the three plans (p>0.05), showing that each plan has the capability of adequately covering the targets. There was a statistically significant difference (p 1cc) there was no statistical difference between the proton plans and the IMRT treatment for the conformity index. Conclusion: A custom proton plan is the recommended treatment explored in this study as it is the most reliable way of effectively treating the target while sparing the maximum amount of normal tissue.

  16. Trilogy Image-Guided Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Huntzinger, Calvin; Friedman, William; Bova, Frank; Fox, Timothy; Bouchet, Lionel; Boeh, Lester M.B.A.

    2007-01-01

    Full integration of advanced imaging, noninvasive immobilization, positioning, and motion-management methods into radiosurgery have resulted in fundamental changes in therapeutic strategies and approaches that are leading us to the treatment room of the future. With the introduction of image-guided radiosurgery (IGRS) systems, such as Trilogy TM , physicians have for the first time a practical means of routinely identifying and treating very small lesions throughout the body. Using new imaging processes such as positron emission tomography/computed tomography (PET/CT) scans, clinics may be able to detect these lesions and then eradicate them with image-guided stereotactic radiosurgery treatments. Thus, there is promise that cancer could be turned into a chronic disease, managed through a series of checkups, and Trilogy treatments when metastatic lesions reappear

  17. Stereotactic Radiosurgery (SRS) / Stereotactic body radiotherapy (SBRT): Benefit to Irish patients and Irish Healthcare Economy

    LENUS (Irish Health Repository)

    Cagney, DN

    2017-01-01

    Cancer incidence across Europe is projected to rise rapidly over the next decade. This rising cancer incidence is mirrored by increasing use of and indications for stereotactic radiation. This paper seeks to summarize the exponential increase in indications for stereotactic radiotherapy as well as the evolving economic advantages of stereotactic radiosurgery and stereotactic body radiotherapy

  18. Stereotactic Radiosurgery and Hypofractionated Radiotherapy for Glioblastoma.

    Science.gov (United States)

    Shah, Jennifer L; Li, Gordon; Shaffer, Jenny L; Azoulay, Melissa I; Gibbs, Iris C; Nagpal, Seema; Soltys, Scott G

    2018-01-01

    Glioblastoma is the most common primary brain tumor in adults. Standard therapy depends on patient age and performance status but principally involves surgical resection followed by a 6-wk course of radiation therapy given concurrently with temozolomide chemotherapy. Despite such treatment, prognosis remains poor, with a median survival of 16 mo. Challenges in achieving local control, maintaining quality of life, and limiting toxicity plague treatment strategies for this disease. Radiotherapy dose intensification through hypofractionation and stereotactic radiosurgery is a promising strategy that has been explored to meet these challenges. We review the use of hypofractionated radiotherapy and stereotactic radiosurgery for patients with newly diagnosed and recurrent glioblastoma. Copyright © 2017 by the Congress of Neurological Surgeons.

  19. Stereotactic radiosurgery: basic concepts and current status

    International Nuclear Information System (INIS)

    Gaur, Maheep Singh

    2016-01-01

    Term Stereotactic Radiosurgery was coined by Prof Lars Leksell in 1951 as concept. Leksell's experimented together with the radiobiologist Borje Larsson in Uppsala, on trying to develop 'stereotactic radiosurgery', aimed at lesioning in the central brain in functional operations such as thalamotomy and capsulotomy. Clinical experiments using a proton beam were initiated at the Gustav Werner Institute in Uppsala, and a few patients had been treated. Experiences from these led Leksell to design a multi-source 'beam knife', which became ready for use in 1967 as the first 'Gamma Knife' and installed at the private hospital Sophiahammet in Stockholm as a clinical research unit. Moving from functional neurosurgery today Gamma knife is used for a wide range on brain tumors, vascular malformations and functional disorders. Introduction of newer technology in navigation and radiation delivery has made it possible to do whole body Radiosurgery. Various technologies, basic principles, radiobiological aspects and applications will be discussed. (author)

  20. Stereotactic radiotherapy for pediatric intracranial germ cell tumors

    International Nuclear Information System (INIS)

    Zissiadis, Yvonne; Dutton, Sharon; Kieran, Mark; Goumnerova, Liliana; Scott, R. Michael; Kooy, Hanne M.; Tarbell, Nancy J.

    2001-01-01

    Purpose: Intracranial germ cell tumors are rare, radiosensitive tumors seen most commonly in the second and third decades of life. Radiotherapy alone has been the primary treatment modality for germinomas, and is used with chemotherapy for nongerminomatous tumors. Stereotactic radiotherapy techniques minimize the volume of surrounding normal tissue irradiated and, hence, the late radiation morbidity. This study reports our experience with stereotactic radiotherapy in this group of tumors. Methods and Materials: Between December 1992 and December 1998, 18 patients with intracranial germ cell tumors were treated with stereotactic radiotherapy. A total of 23 histologically proven tumors were treated. Thirteen patients had a histologic diagnosis of germinoma, and 5 patients had germinoma with nongerminomatous elements. Of those patients with a histologic diagnosis of germinoma, 5 had multiple midline tumors. The median age of the patients was 12.9 years (range, 5.6-17.5 years). Results: A boost using stereotactic radiotherapy was delivered to 19 tumors following whole-brain radiation in 8 cases and craniospinal radiation in 11 cases. Three tumors were treated with stereotactic radiotherapy to the tumor volume alone following chemotherapy, and 1 tumor received a boost using stereotactic radiosurgery following craniospinal radiation. A median dose of 2520 cGy (range, 1500-3600) cGy was given to the whole brain, and a median dose of 2160 (range, 2100-2600) cGy was given to the spinal field. The median boost dose to the tumor was 2600 (range, 2160-3600) cGy, given by stereotactic radiotherapy delivered to the 95% isodose line. At a median follow-up time of 40 (range, 12-73) months, no local or marginal recurrences were reported in patients with germinoma. Two patients with nongerminomatous tumors have relapsed. One had elevation of tumor markers only at 37 months following treatment, and the other had persistent disease following chemotherapy and radiation therapy. Eight

  1. Stereotactic radiosurgery for the treatment of brain metastases; results from a single institution experience.

    LENUS (Irish Health Repository)

    Burke, D

    2013-09-01

    Stereotactic radiosurgery is frequently used for the treatment of brain metastases. This study provides a retrospective evaluation of patients with secondary lesions of the brain treated with stereotactic radiosurgery (SRS) at our institution.

  2. Frame-less image-guided intracranial and extracranial radiosurgery using the Cyberknife robotic system

    International Nuclear Information System (INIS)

    Gibbs, I.C.

    2006-01-01

    The Cyberknife TM is an image-guided robotic radiosurgery system. The image guidance system includes a kilo-voltage X-ray imaging source and amorphous silica detectors. The radiation delivery device is a mobile X-band linear accelerator mounted onto a robotic arm. Through a highly complex interplay between the image guidance system, an automated couch, and the high-speed linear accelerator, near real-time tracking of the target is achieved. The Cyberknife TM gained Federal Drug Administration clearance in the United States in 2001 for treatment of tumors 'anywhere in the body where radiation treatment is indicated'. Because the Cyberknife TM system does not rely on rigid fixation of a stereotactic frame, tumors outside of the intracranial compartment, even those tumors that move with respiration can be treated with a similar degree of ease as intracranial targets. A description of the Cyberknife TM technology and a review of some of the current intracranial and extracranial applications are detailed herein. (author)

  3. Management of vestibular schwannomas with linear accelerator-based stereotactic radiosurgery: a single center experience.

    Science.gov (United States)

    Sager, Omer; Beyzadeoglu, Murat; Dincoglan, Ferrat; Demiral, Selcuk; Uysal, Bora; Gamsiz, Hakan; Oysul, Kaan; Dirican, Bahar; Sirin, Sait

    2013-01-01

    The primary goal of treatment for vestibular schwannoma is to achieve local control without comprimising regional cranial nerve function. Stereotactic radiosurgery has emerged as a viable therapeutic option for vestibular schwannoma. The aim of the study is to report our 15-year single center experience using linear accelerator-based stereotactic radiosurgery in the management of patients with vestibular schwannoma. Between July 1998 and January 2013, 68 patients with unilateral vestibular schwannoma were treated using stereotactic radiosurgery at the Department of Radiation Oncology, Gulhane Military Medical Academy. All patients underwent high-precision stereotactic radiosurgery using a linear accelerator with 6-MV photons. Median follow-up time was 51 months (range, 9-107). Median age was 45 years (range, 20-77). Median dose was 12 Gy (range, 10-13) prescribed to the 85%-95% isodose line encompassing the target volume. Local tumor control in patients with periodic follow-up imaging was 96.1%. Overall hearing preservation rate was 76.5%. Linear accelerator-based stereotactic radiosurgery offers a safe and effective treatment for patients with vestibular schwannoma by providing high local control rates along with improved quality of life through well-preserved hearing function.

  4. Measurement of relative dose distributions in stereotactic radiosurgery by the polymer-gel dosimeter

    Czech Academy of Sciences Publication Activity Database

    Novotný ml., J.; Spěváček, V.; Hrbáček, J.; Judas, L.; Novotný, J.; Dvořák, P.; Tlacháčová, D.; Schmitt, M.; Tintěra, J.; Vymazal, J.; Čechák, T.; Michálek, Jiří; Přádný, Martin; Liščák, R.

    2004-01-01

    Roč. 5, - (2004), s. 225-235 ISSN 1024-2651. [International Stereotactic Radiosurgery Society Meeting /6./. Kyoto, 22.06.2003-26.06.2003] R&D Projects: GA MZd NC7460 Institutional research plan: CEZ:AV0Z4050913 Keywords : stereotactic radiosurgery * polymer-gel dosimeter Subject RIV: FD - Oncology ; Hematology

  5. Stereotactic radiosurgery planning with ictal SPECT images

    International Nuclear Information System (INIS)

    Ackerly, T.; RMIT University, Bundoora, VIC; Geso, M.; O'Keefe, G.; Smith, R.

    2004-01-01

    This paper is motivated by a clinical requirement to utilise ictal SPECT images for target localisation in stereotactic radiosurgery treatment planning using the xknife system which only supports CT and MRI images. To achieve this, the SPECT images were converted from raw (pixel data only) format into a part 10 compliant DICOM CT fileset. The minimum requirements for the recasting of a raw format image as DICOM CT or MRI data set are described in detail. The method can be applied to the importation of raw format images into any radiotherapy treatment planning system that supports CT or MRI import. It is demonstrated that the combination of the low spatial resolution SPECT images, depicting functional information, with high spatial resolution MRI images, which show the structural information, is suitable for stereotactic radiosurgery treatment planning. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  6. Stereotactic radiosurgery with an upper partial denture

    International Nuclear Information System (INIS)

    Tayama, Shusaku; Kunieda, Etsuo; Takeda, Atsushi; Takeda, Toshiaki; Oku, Yohei

    2009-01-01

    A 54-year-old male with partial denture underwent stereotactic radiosurgery with an infrared camera-guided system for a metastatic brain tumor arising from lung cancer. Although this method utilizes a biteplate mounted on the upper jaw to detect head movement, the patient only had four teeth in his upper jaw. In order to stabilize the biteplate, the maxillary denture was fixed to the biteplate with an autopolymerizing resin. In addition, the rest-occlusal position of the lower jaw was impressed on the inferior surface of the biteplate with an autopolymerizing resin. To assess reproducibility and stability, the distance between the left and right incus and left and right markers was measured during pre-planning, as well as before and after stereotactic irradiation. Wearing the biteplate ensures the accuracy of radiotherapy planning for the implementation of radiosurgery in patients who have many maxillary teeth missing. However, a large degree of error was observed when the biteplate was removed. (author)

  7. Gamma Knife radiosurgery for the treatment of intracranial dural arteriovenous fistulas

    Science.gov (United States)

    Dmytriw, Adam A; Schwartz, Michael L; Cusimano, Michael D; Mendes Pereira, Vitor; Krings, Timo; Tymianski, Michael; Radovanovic, Ivan

    2016-01-01

    Background Intracranial dural arteriovenous fistulae (DAVF) may present a treatment challenge. Endovascular embolization is in most cases the first line of treatment but does not always achieve cure. Gamma Knife (GK) radiosurgery represents an alternative treatment option, and the purpose of this study was to further evaluate its utility. Methods We reviewed all cases of DAVF treated between 2009 and 2016 at our institution with GK radiosurgery independently, or following failed/refused endovascular or surgical management. Patients’ clinical files, radiological images, catheter angiograms, and surgical DAVF disconnection reports were retrospectively reviewed. Results Sixteen DAVF (14 patients) treated by GK radiosurgery were identified. Eleven fistulae were aggressive and five were benign. Marginal doses ranged from 15 to 25 Gy. Target volumes ranged from 0.04 to 4.47 cm3. In all symptomatic patients, GK treatment resulted in symptom palliation. In 13/15 lesions, cure of symptoms (86.0%) was reported. One lesion was asymptomatic. Angiographic cure was achieved in eight cases (50%), small residual DAVF occurred in four, and four were unchanged. One patient developed headache that resolved at one year. No hemorrhage occurred during the follow-up period. There was no significant association between Borden type and cure rate. Prior failed endovascular treatment and small target volume were associated with lower rates of cure. Conclusions Stereotactic radiosurgery is viable treatment for DAVF. It is very effective in palliating symptoms as a de novo approach or adjunctive to endovascular therapy. In our experience it is only somewhat effective in achieving complete angiographic cure. PMID:28156167

  8. Comparison of static conformal field with multiple noncoplanar arc techniques for stereotactic radiosurgery or stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Hamilton, Russell J.; Kuchnir, Franca T.; Sweeney, Patrick; Rubin, Steven J.; Dujovny, Manuel; Pelizzari, Charles A.; Chen, George T. Y.

    1995-01-01

    Purpose: Compare the use of static conformal fields with the use of multiple noncoplanar arcs for stereotactic radiosurgery or stereotactic radiotherapy treatment of intracranial lesions. Evaluate the efficacy of these treatment techniques to deliver dose distributions comparable to those considered acceptable in current radiotherapy practice. Methods and Materials: A previously treated radiosurgery case of a patient presenting with an irregularly shaped intracranial lesion was selected. Using a three-dimensional (3D) treatment-planning system, treatment plans using a single isocenter multiple noncoplanar arc technique and multiple noncoplanar conformal static fields were generated. Isodose distributions and dose volume histograms (DVHs) were computed for each treatment plan. We required that the 80% (of maximum dose) isodose surface enclose the target volume for all treatment plans. The prescription isodose was set equal to the minimum target isodose. The DVHs were analyzed to evaluate and compare the different treatment plans. Results: The dose distribution in the target volume becomes more uniform as the number of conformal fields increases. The volume of normal tissue receiving low doses (> 10% of prescription isodose) increases as the number of static fields increases. The single isocenter multiple arc plan treats the greatest volume of normal tissue to low doses, approximately 1.6 times more volume than that treated by four static fields. The volume of normal tissue receiving high (> 90% of prescription isodose) and intermediate (> 50% of prescription isodose) doses decreases by 29 and 22%, respectively, as the number of static fields is increased from four to eight. Increasing the number of static fields to 12 only further reduces the high and intermediate dose volumes by 10 and 6%, respectively. The volume receiving the prescription dose is more than 3.5 times larger than the target volume for all treatment plans. Conclusions: Use of a multiple noncoplanar

  9. Linac radiosurgery for high-grade gliomas: the University of Florida experience

    Energy Technology Data Exchange (ETDEWEB)

    Buatti, John M; Friedman, William A; Bova, Frank J; Mendenhall, William M

    1995-04-30

    Purpose: Stereotactic radiosurgery has been reported as a promising boost technique for the treatment of selected patients with high-grade glioma. The first 11 patients given this treatment at the University of Florida are reported. Methods and Materials: Six patients with glioblastoma multiforme and five with anaplastic astrocytoma were carefully selected for treatment with linac radiosurgery. All patients had a Karnofsky performance status {>=} 90%. Median age of patients was 42.1 years. External-beam radiotherapy delivered a median dose of 60 Gy. Stereotactic radiosurgery was delivered to the enhancing tumor volume without margin. Median treatment volume was 14 cm{sup 3} (equivalent sphere diameter, 3 cm). The maximum volume of any tumor treated was 22.5 cm{sup 3} (equivalent sphere diameter, 3.5 cm). Median stereotactic radiosurgery boost dose was 12.5 Gy, and median prescription sphere was the 80% isodose shell. Results: Despite rigorous selection and aggressive stereotactic boost irradiation, this patient cohort had a median actuarial survival of 17 months. All patients have had progression of intracranial disease within 1 year of radiosurgery, and only 3 of 11 remain alive with a median follow-up of 13 months. Conclusion: These results differ significantly from others reported. Comparative analysis suggests tumor volume may be an important prognostic factor in patients treated with stereotactic radiosurgery. Future studies need to define appropriate patient cohorts for the boost technique.

  10. The study on linac stereotactic radiosurgery for acoustic tumors

    International Nuclear Information System (INIS)

    Ohishi, Hitoshi

    1995-01-01

    We have designed and manufactured a new type of device for stereotactic radiosurgery characterized by the combined use of a rotatory chair and a linear accelerator. In this study, 20 acoustic tumors treated by our modality were evaluated by serial neuroimaging, neurofunctional outcome and, in a few cases, pathological findings of surgical specimens. Because tumor size usually changed very slowly after radiosurgery, 12 cases that had a minimum of 12 months of follow-up were employed in the analysis of tumor size. Serial neuroimaging studies revealed the reduction of tumor size in 3 cases and prevention of tumor growth in 7 cases, therefore, the rate of tumor control was evaluated as 83%. Growth of tumor size occurred in 3 cases, two were cases harbouring a large cyst in the tumor and another was a case of neurofibromatosis type 2. In 13 cases (68%), loss of the gadolinium enhancement effect inside the tumor was observed. This is a characteristic change after radiosurgery for acoustic tumors, and attributable to a necrotic change. Cranial nerve neuropathies as a complication also occurred (facial nerve palsy in 2 and trigeminal nerve dysfunction in 1). Adjacent parenchymal change appeared in 1 case. This patient had two prior operations and the tumor had an irregular shape, therefore, planning for radiosurgery encountered some difficulty. Hydrocephalus occurred in 1 case. Surgical specimens in 2 cases in which microsurgery was undertaken for growing tumors, revealed a necrotic tumor tissue and proliferation of fibrous tissue. In conclusion, our new device for stereotactic radiosurgery is particularly useful for the treatment of acoustic tumors. Similar therapeutic results of the gamma knife have been achieved. Radiosurgery is a recommendable treatment for acoustic tumors. However, the superiority of radiosurgery over microsurgery is still controversial and needs a longer term follow-up and multivariate analysis for a final conclusion. (author)

  11. Stereotactic Bragg peak proton radiosurgery method

    International Nuclear Information System (INIS)

    Kjellberg, R.N.

    1979-01-01

    A brief description of the technical aspects of a stereotactic Bragg peak proton radiosurgical method for the head is presented. The preparatory radiographic studies are outlined and the stereotactic instrument and positioning of the patient are described. The instrument is so calibrated that after corrections for soft tissue and bone thickness, the Bragg peak superimposes upon the intracranial target. The head is rotated at specific intervals to allow predetermined portals of access for the beam path, all of which converge on the intracranial target. Normally, portals are arranged to oppose and overlap from both sides of the head. Using a number of beams (in sequence) on both sides of the head, the target dose is far greater than the path dose. The procedure normally takes 3/2-2 hours, following which the patient can walk away. (Auth./C.F.)

  12. Late clinical and radiological complications of stereotactical radiosurgery of arteriovenous malformations of the brain

    Energy Technology Data Exchange (ETDEWEB)

    Parkhutik, Vera [Hospital Universitario la Fe, Department of Neurology, Valencia (Spain); Universidad Autonoma de Barcelona, PhD Program of the Department of Medicine, Barcelona (Spain); Lago, Aida; Vazquez, Juan Francisco; Tembl, Jose Ignacio [Hospital Universitario la Fe, Department of Neurology, Valencia (Spain); Aparici, Fernando; Guillen, Lourdes; Mainar, Esperanza; Vazquez, Victor [Hospital Universitario la Fe, Department of Neuroradiology, Valencia (Spain)

    2013-04-15

    Post-radiation injury of patients with brain arteriovenous malformations (AVM) include blood-brain barrier breakdown (BBBB), edema, and necrosis. Prevalence, clinical relevance, and response to treatment are poorly known. We present a series of consecutive brain AVM treated with stereotactic radiosurgery describing the appearance of radiation injury and clinical complications. Consecutive patients with annual clinical and radiological follow-up (median length 63 months). Edema and BBBB were classified in four groups (minimal, perilesional, moderate, or severe), and noted together with necrosis. Clinical symptoms of interest were intracranial hypertension, new neurological deficits, new seizures, and brain hemorrhages. One hundred two cases, median age 34 years, 52 % male. Median irradiated volume 3.8 cc, dose to the margin of the nidus 18.5 Gy. Nineteen patients underwent a second radiosurgery. Only 42.2 % patients remained free from radiation injury. Edema was found in 43.1 %, blood-brain barrier breakdown in 20.6 %, necrosis in 6.9 %. Major injury (moderate or severe edema, moderate or severe BBBB, or necrosis) was found in 20 of 102 patients (19.6 %). AVM diameter >3 cm and second radiosurgery were independent predictors. Time to the worst imaging was 60 months. Patients with major radiation injury had a hazard ratio for appearance of focal deficits of 7.042 (p = 0.04), of intracranial hypertension 2.857 (p = 0.025), hemorrhage into occluded nidus 9.009 (p = 0.079), appearance of new seizures not significant. Major radiation injury is frequent and increases the risk of neurological complications. Its late appearance implies that current follow-up protocols need to be extended in time. (orig.)

  13. Targeting Accuracy of Image-Guided Radiosurgery for Intracranial Lesions: A Comparison Across Multiple Linear Accelerator Platforms.

    Science.gov (United States)

    Huang, Yimei; Zhao, Bo; Chetty, Indrin J; Brown, Stephen; Gordon, James; Wen, Ning

    2016-04-01

    To evaluate the overall positioning accuracy of image-guided intracranial radiosurgery across multiple linear accelerator platforms. A computed tomography scan with a slice thickness of 1.0 mm was acquired of an anthropomorphic head phantom in a BrainLAB U-frame mask. The phantom was embedded with three 5-mm diameter tungsten ball bearings, simulating a central, a left, and an anterior cranial lesion. The ball bearings were positioned to radiation isocenter under ExacTrac X-ray or cone-beam computed tomography image guidance on 3 Linacs: (1) ExacTrac X-ray localization on a Novalis Tx; (2) cone-beam computed tomography localization on the Novalis Tx; (3) cone-beam computed tomography localization on a TrueBeam; and (4) cone-beam computed tomography localization on an Edge. Each ball bearing was positioned 5 times to the radiation isocenter with different initial setup error following the 4 image guidance procedures on the 3 Linacs, and the mean (µ) and one standard deviation (σ) of the residual error were compared. Averaged overall 3 ball bearing locations, the vector length of the residual setup error in mm (µ ± σ) was 0.6 ± 0.2, 1.0 ± 0.5, 0.2 ± 0.1, and 0.3 ± 0.1 on ExacTrac X-ray localization on a Novalis Tx, cone-beam computed tomography localization on the Novalis Tx, cone-beam computed tomography localization on a TrueBeam, and cone-beam computed tomography localization on an Edge, with their range in mm being 0.4 to 1.1, 0.4 to 1.9, 0.1 to 0.5, and 0.2 to 0.6, respectively. The congruence between imaging and radiation isocenters in mm was 0.6 ± 0.1, 0.7 ± 0.1, 0.3 ± 0.1, and 0.2 ± 0.1, for the 4 systems, respectively. Targeting accuracy comparable to frame-based stereotactic radiosurgery can be achieved with image-guided intracranial stereotactic radiosurgery treatment. © The Author(s) 2015.

  14. Stereotactic Radiosurgery in the Management of Brain Metastases: An Institutional Retrospective Analysis of Survival

    International Nuclear Information System (INIS)

    Frazier, James L.; Batra, Sachin; Kapor, Sumit; Vellimana, Ananth; Gandhi, Rahul; Carson, Kathryn A.; Shokek, Ori; Lim, Michael; Kleinberg, Lawrence; Rigamonti, Daniele

    2010-01-01

    Purpose: The objective of this study was to report our experience with stereotactic radiosurgery performed with the Gamma Knife (GK) in the treatment of patients with brain metastases and to compare survival for those treated with radiosurgery alone with survival for those treated with radiosurgery and whole-brain radiotherapy. Methods and Materials: Prospectively collected demographic and clinical characteristics and treatment and survival data on 237 patients with intracranial metastases who underwent radiosurgery with the GK between 2003 and 2007 were reviewed. Kaplan-Meier and Cox proportional hazards regression analyses were used to compare survival by demographic and clinical characteristics and treatment. Results: The mean age of the patient population was 56 years. The most common tumor histologies were non-small-cell lung carcinoma (34.2%) and breast cancer (13.9%). The median overall survival time was 8.5 months from the time of treatment. The median survival times for patients with one, two/three, and four or more brain metastases were 8.5, 9.4, and 6.7 months, respectively. Patients aged 65 years or greater and those aged less than 65 years had median survival times of 7.8 and 9 months, respectively (p = 0.008). The Karnofsky Performance Score (KPS) at the time of treatment was a significant predictor of survival: those patients with a KPS of 70 or less had a median survival of 2.9 months compared with 10.3 months (p = 0.034) for those with a KPS of 80 or greater. There was no statistically significant difference in survival between patients treated with radiosurgery alone and those treated with radiosurgery plus whole-brain radiotherapy. Conclusions: Radiosurgery with the GK is an efficacious treatment modality for brain metastases. A KPS greater than 70, histology of breast cancer, smaller tumor volume, and age less than 65 years were associated with a longer median survival in our study.

  15. [Possibility of 3D Printing in Ophthalmology - First Experiences by Stereotactic Radiosurgery Planning Scheme of Intraocular Tumor].

    Science.gov (United States)

    Furdová, A; Furdová, Ad; Thurzo, A; Šramka, M; Chorvát, M; Králik, G

    Nowadays 3D printing allows us to create physical objects on the basis of digital data. Thanks to its rapid development the use enormously increased in medicine too. Its creations facilitate surgical planning processes, education and research in context of organ transplantation, individualization prostheses, breast forms, and others.Our article describes the wide range of applied 3D printing technology possibilities in ophthalmology. It is focusing on innovative implementation of eye tumors treatment planning in stereotactic radiosurgery irradiation.We analyze our first experience with 3D printing model of the eye in intraocular tumor planning stereotactic radiosurgery. 3D printing, model, Fused Deposition Modelling, stereotactic radiosurgery, prostheses, intraocular tumor.

  16. Technical Note: Evaluation of the systematic accuracy of a frameless, multiple image modality guided, linear accelerator based stereotactic radiosurgery system

    Energy Technology Data Exchange (ETDEWEB)

    Wen, N., E-mail: nwen1@hfhs.org; Snyder, K. C.; Qin, Y.; Li, H.; Siddiqui, M. S.; Chetty, I. J. [Department of Radiation Oncology, Henry Ford Health System, 2799 West Brand Boulevard, Detroit, Michigan 48202 (United States); Scheib, S. G.; Schmelzer, P. [Varian Medical System, Täfernstrasse 7, Dättwil AG 5405 (Switzerland)

    2016-05-15

    Purpose: To evaluate the total systematic accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy and intermodality difference was determined by delivering radiation to an end-to-end prototype phantom, in which the targets were localized using optical surface monitoring system (OSMS), electromagnetic beacon-based tracking (Calypso®), cone-beam CT, “snap-shot” planar x-ray imaging, and a robotic couch. Six IMRT plans with jaw tracking and a flattening filter free beam were used to study the dosimetric accuracy for intracranial and spinal stereotactic radiosurgery treatment. Results: End-to-end localization accuracy of the system evaluated with the end-to-end phantom was 0.5 ± 0.2 mm with a maximum deviation of 0.9 mm over 90 measurements (including jaw, MLC, and cone measurements for both auto and manual fusion) for single isocenter, single target treatment, 0.6 ± 0.4 mm for multitarget treatment with shared isocenter. Residual setup errors were within 0.1 mm for OSMS, and 0.3 mm for Calypso. Dosimetric evaluation based on absolute film dosimetry showed greater than 90% pass rate for all cases using a gamma criteria of 3%/1 mm. Conclusions: The authors’ experience demonstrates that the localization accuracy of the frameless image-guided system is comparable to robotic or invasive frame based radiosurgery systems.

  17. Technical Note: Evaluation of the systematic accuracy of a frameless, multiple image modality guided, linear accelerator based stereotactic radiosurgery system

    International Nuclear Information System (INIS)

    Wen, N.; Snyder, K. C.; Qin, Y.; Li, H.; Siddiqui, M. S.; Chetty, I. J.; Scheib, S. G.; Schmelzer, P.

    2016-01-01

    Purpose: To evaluate the total systematic accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy and intermodality difference was determined by delivering radiation to an end-to-end prototype phantom, in which the targets were localized using optical surface monitoring system (OSMS), electromagnetic beacon-based tracking (Calypso®), cone-beam CT, “snap-shot” planar x-ray imaging, and a robotic couch. Six IMRT plans with jaw tracking and a flattening filter free beam were used to study the dosimetric accuracy for intracranial and spinal stereotactic radiosurgery treatment. Results: End-to-end localization accuracy of the system evaluated with the end-to-end phantom was 0.5 ± 0.2 mm with a maximum deviation of 0.9 mm over 90 measurements (including jaw, MLC, and cone measurements for both auto and manual fusion) for single isocenter, single target treatment, 0.6 ± 0.4 mm for multitarget treatment with shared isocenter. Residual setup errors were within 0.1 mm for OSMS, and 0.3 mm for Calypso. Dosimetric evaluation based on absolute film dosimetry showed greater than 90% pass rate for all cases using a gamma criteria of 3%/1 mm. Conclusions: The authors’ experience demonstrates that the localization accuracy of the frameless image-guided system is comparable to robotic or invasive frame based radiosurgery systems.

  18. Optimal technique of linear accelerator-based stereotactic radiosurgery for tumors adjacent to brainstem.

    Science.gov (United States)

    Chang, Chiou-Shiung; Hwang, Jing-Min; Tai, Po-An; Chang, You-Kang; Wang, Yu-Nong; Shih, Rompin; Chuang, Keh-Shih

    2016-01-01

    Stereotactic radiosurgery (SRS) is a well-established technique that is replacing whole-brain irradiation in the treatment of intracranial lesions, which leads to better preservation of brain functions, and therefore a better quality of life for the patient. There are several available forms of linear accelerator (LINAC)-based SRS, and the goal of the present study is to identify which of these techniques is best (as evaluated by dosimetric outcomes statistically) when the target is located adjacent to brainstem. We collected the records of 17 patients with lesions close to the brainstem who had previously been treated with single-fraction radiosurgery. In all, 5 different lesion catalogs were collected, and the patients were divided into 2 distance groups-1 consisting of 7 patients with a target-to-brainstem distance of less than 0.5cm, and the other of 10 patients with a target-to-brainstem distance of ≥ 0.5 and linear accelerator is only 1 modality can to establish for SRS treatment. Based on statistical evidence retrospectively, we recommend VMAT as the optimal technique for delivering treatment to tumors adjacent to brainstem. Copyright © 2016 American Association of Medical Dosimetrists. All rights reserved.

  19. Stereotactic radiosurgery using a linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kyuma, Yoshikazu; Hayashi, Akimune; Kitamura, Tatsuo; Yamashita, Koosuke; Muranishi, Hisayuki; Hioki, Minoru [Kanagawa Cancer Center, Yokohama (Japan)

    1992-07-01

    A basic and clinical study of radiosurgery using the linear accelerator (Linac) system for unremovable deep-seated brain tumors is reported. A Komai stereotactic ring was used to locate the target coordinates. The patient was laid on the Linac treatment table and held in the head fixation system. Irradiation was given in five positions. The dose profile by film dosimetry and Rando phantom was satisfactory. Seventeen tumors in 14 patients were treated. Clinical or histological diagnoses were nine metastases, one benign and two malignant gliomas, one meningioma, and one carcinopharyngioma. Tumor sizes were between 8 and 30 mm. Doses were between 12 and 30 Gy. Computed tomographic evaluation after 3 months of 12 tumors in 11 survivors showed one complete remission, three partial remission, six no change, and two partial deterioration. For progressive tumors, Linac radiosurgery results are excellent. (author).

  20. Stereotactic radiosurgery and its potential in neurological practice: our first experience

    International Nuclear Information System (INIS)

    Vladarova, D.

    1991-01-01

    The history of radiosurgery of the brain, and experience with the use of beams of ionizing radiation in the therapy of intracranial tumors and arteriovenous malformations are dealt with. Leksell's gamma knife and the way of its use are described. Techniques of stereotactically directed narrow gamma beams with a steep radiation dose gradient serve to subject sharply bounded volumes of tissue to high radiation doses. Owing to a system of collimators, the effect of radiation on the surrounding tissues is negligible. The whole procedure, including the previous angiography and the corresponding calculations, takes 5 to 30 minutes. The latent time after the surgery during which a complete obliteration of the pathological blood vessels takes place is a drawback; this latent time is typically from 4 months to 2 years. World experience in the therapy by this method and the first two cases of patients in Czechoslovakia are described. (M.D.). 1 fig., 12 refs

  1. The current status of radiosurgery

    International Nuclear Information System (INIS)

    Mehta, Minesh P.

    1996-01-01

    Objectives: Review the role of radiosurgery in recurrent malignant gliomas for palliative purposes. Review the role of radiosurgery in newly diagnosed malignant glioma as boost therapy and emphasize the randomized clinical trials underway. Review the role of radiosurgery in the management of patients with brain metastases and emphasize the major prognostic factors. Review the recently initiated clinical trials for brain metastases using radiosurgery. Review the role of radiosurgery in the management of benign tumors with specific emphasis on meningioma and acoustic neuroma. Emphasize the rationale for fractionation and present the preliminary results of fractionated stereotactic radiation. Stereotactic localization techniques, originally designed for neurosurgery, have been used to delivery high single doses of radiation to small intracranial targets for more than 25 years, a technique referred to as stereotactic radiosurgery. Radiosurgery has proven to be an attractive alternative to surgery in the management of several benign tumors, such as vestibular schwannomas with better preservation of hearing and facial nerve function than microsurgical resection. For other benign tumors such as meningioma and pituitary adenoma, preliminary results are promising, but longer range studies to confirm high tumor control rates are necessary. For patients with malignant glioma, radiosurgery has been used to escalate the radiation dose to enhance tumor control following surgery and radiation therapy. The rationale for this is grounded in the recent confirmatory randomized prospective trial verifying the value of brachytherapy in this disease. The results of radiosurgery from single institutional experiences for primary and recurrent malignant glioma indicate a palliative benefit as well as a potential survival benefit in a select sub-group of patients based on the appropriate mix of prognostic criteria such as patient age, performance status, tumor size and extent of resection

  2. Dosimetric performance of the new high-definition multileaf collimator for intracranial stereotactic radiosurgery.

    Science.gov (United States)

    Dhabaan, Anees; Elder, Eric; Schreibmann, Eduard; Crocker, Ian; Curran, Walter J; Oyesiku, Nelson M; Shu, Hui-Kuo; Fox, Tim

    2010-06-21

    The objective was to evaluate the performance of a high-definition multileaf collimator (MLC) of 2.5 mm leaf width (MLC2.5) and compare to standard 5 mm leaf width MLC (MLC5) for the treatment of intracranial lesions using dynamic conformal arcs (DCA) technique with a dedicated radiosurgery linear accelerator. Simulated cases of spherical targets were created to study solely the effect of target volume size on the performance of the two MLC systems independent of target shape complexity. In addition, 43 patients previously treated for intracranial lesions in our institution were retrospectively planned using DCA technique with MLC2.5 and MLC5 systems. The gross tumor volume ranged from 0.07 to 40.57 cm3 with an average volume of 5.9 cm3. All treatment parameters were kept the same for both MLC-based plans. The plan evaluation was performed using figures of merits (FOM) for a rapid and objective assessment on the quality of the two treatment plans for MLC2.5 and MLC5. The prescription isodose surface was selected as the greatest isodose surface covering >or= 95% of the target volume and delivering 95% of the prescription dose to 99% of target volume. A Conformity Index (CI) and conformity distance index (CDI) were used to quantifying the dose conformity to a target volume. To assess normal tissue sparing, a normal tissue difference (NTD) was defined as the difference between the volume of normal tissue receiving a certain dose utilizing MLC5 and the volume receiving the same dose using MLC2.5. The CI and normal tissue sparing for the simulated spherical targets were better with the MLC2.5 as compared to MLC5. For the clinical patients, the CI and CDI results indicated that the MLC2.5 provides better treatment conformity than MLC5 even at large target volumes. The CI's range was 1.15 to 2.44 with a median of 1.59 for MLC2.5 compared to 1.60-2.85 with a median of 1.71 for MLC5. Improved normal tissue sparing was also observed for MLC2.5 over MLC5, with the NTD always

  3. Combining stereotactic radiosurgery and systemic therapy for brain metastases: a potential role for temozolomide

    Energy Technology Data Exchange (ETDEWEB)

    Hardee, Matthew E. [Department of Radiation Oncology, New York University Langone Medical Center, New York, NY (United States); Formenti, Silvia C., E-mail: silvia.formenti@nyumc.org [Department of Radiation Oncology, New York University Langone Medical Center, New York, NY (United States); Department of Medical Oncology, New York University Langone Medical Center, New York, NY (United States)

    2012-08-09

    Brain metastases are unfortunately very common in the natural history of many solid tumors and remain a life-threatening condition, associated with a dismal prognosis, despite many clinical trials aimed at improving outcomes. Radiation therapy options for brain metastases include whole brain radiotherapy (WBRT) and stereotactic radiosurgery (SRS). SRS avoids the potential toxicities of WBRT and is associated with excellent local control (LC) rates. However, distant intracranial failure following SRS remains a problem, suggesting that untreated intracranial micrometastatic disease is responsible for failure of treatment. The oral alkylating agent temozolomide (TMZ), which has demonstrated efficacy in primary malignant central nervous system tumors such as glioblastoma, has been used in early phase trials in the treatment of established brain metastases. Although results of these studies in established, macroscopic metastatic disease have been modest at best, there is clinical and preclinical data to suggest that TMZ is more efficacious at treating and controlling clinically undetectable intracranial micrometastatic disease. We review the available data for the primary management of brain metastases with SRS, as well as the use of TMZ in treating established brain metastases and undetectable micrometastatic disease, and suggest the role for a clinical trial with the aims of treating macroscopically visible brain metastases with SRS combined with TMZ to address microscopic, undetectable disease.

  4. Proton beam stereotactic radiosurgery of vestibular schwannomas

    International Nuclear Information System (INIS)

    Harsh, Griffith R.; Thornton, Allan F.; Chapman, Paul H.; Bussiere, Marc R.; Rabinov, James D.; Loeffler, Jay S.

    2002-01-01

    Purpose: The proton beam's Bragg peak permits highly conformal radiation of skull base tumors. This study, prompted by reports of transient (30% each) and permanent (10% each) facial and trigeminal neuropathy after stereotactic radiosurgery of vestibular schwannomas with marginal doses of 16-20 Gy, assessed whether proton beam radiosurgery using a marginal dose of only 12 Gy could control vestibular schwannomas while causing less neuropathy. Methods and Materials: Sixty-eight patients (mean age 67 years) were treated between 1992 and 1998. The mean tumor volume was 2.49 cm 3 . The dose to the tumor margin (70% isodose line) was 12 Gy. The prospectively specified follow-up consisted of neurologic evaluation and MRI at 6, 12, 24, and 36 months. Results: After a mean clinical follow-up of 44 months and imaging follow-up of 34 months in 64 patients, 35 tumors (54.7%) were smaller and 25 (39.1%) were unchanged (tumor control rate 94%; actuarial control rate 94% at 2 years and 84% at 5 years). Three tumors enlarged: one shrank after repeated radiosurgery, one remained enlarged at the time of unrelated death, and one had not been imaged for 4 years in a patient who remained asymptomatic at last follow-up. Intratumoral hemorrhage into one stable tumor required craniotomy that proved successful. Thus, 97% of tumors required no additional treatment. Three patients (4.7%) underwent shunting for hydrocephalus evident as increased ataxia. Of 6 patients with functional hearing ipsilaterally, 1 improved, 1 was unchanged, and 4 progressively lost hearing. Cranial neuropathies were infrequent: persistent facial hypesthesia (2 new, 1 exacerbated; 4.7%); intermittent facial paresthesias (5 new, 1 exacerbated; 9.4%); persistent facial weakness (2 new, 1 exacerbated; 4.7%) requiring oculoplasty; transient partial facial weakness (5 new, 1 exacerbated; 9.4%), and synkinesis (5 new, 1 exacerbated; 9.4%). Conclusion: Proton beam stereotactic radiosurgery of vestibular schwannomas at the

  5. Stereotactic Target point Verification in Actual Treatment Position of Radiosurgery

    International Nuclear Information System (INIS)

    Yun, Hyong Geun; Lee, Hyun Koo

    1995-01-01

    Purpose : Authors tried to enhance the safety and accuracy of radiosurgery by verifying stereotactic target point in actual treatment position prior to irradiation. Materials and Methods : Before the actual treatment, several sections of anthropomorphic head phantom were used to create a condition of unknown coordinated of the target point. A film was sand witched between the phantom sections and punctured by sharp needle tip. The tip of the needle represented the target point. The head phantom was fixed to the stereotactic ring and CT scan was done with CT localizer attached to the ring. After the CT scanning, the stereotactic coordinates of the target point were determined. The head phantom was secured to accelerator's treatment couch and the movement of laser isocenter to the stereotactic coordinates determined by CT scanning was performed using target positioner. Accelerator's anteroposterior and lateral portal films were taken using angiographic localizers. The stereotactic coordinates determined by analysis of portal films were compared with the stereotactic coordinates previously determined by CT scanning. Following the correction of discrepancy, the head phantom was irradiated using a stereotactic technique of several arcs. After the irradiation, the film which was sand witched between the phantom sections was developed and the degree of coincidence between the center of the radiation distribution with the target point represented by the hole in the film was measured. In the treatment of actual patients, the way of determining the stereotactic coordinates with CT localizers and angiographic localizers between two sets of coordinates, we proceeded to the irradiation of the actual patient. Results : In the phantom study, the agreement between the center of the radiation distribution and the localized target point was very good. By measuring optical density profiles of the sand witched film along axes that intersected the target point, authors could confirm

  6. Stereotactic radiosurgery for deep intracranial arteriovenous malformations, part 1: Brainstem arteriovenous malformations.

    Science.gov (United States)

    Cohen-Inbar, Or; Ding, Dale; Chen, Ching-Jen; Sheehan, Jason P

    2016-02-01

    The management of brainstem arteriovenous malformations (AVM) are one of the greatest challenges encountered by neurosurgeons. Brainstem AVM have a higher risk of hemorrhage compared to AVM in other locations, and rupture of these lesions commonly results in devastating neurological morbidity and mortality. The potential morbidity associated with currently available treatment modalities further compounds the complexity of decision making for affected patients. Stereotactic radiosurgery (SRS) has an important role in the management of brainstem AVM. SRS offers acceptable obliteration rates with lower risks of hemorrhage occurring during the latency period. Complex nidal architecture requires a multi-disciplinary treatment approach. Nidi partly involving subpial/epipial regions of the dorsal midbrain or cerebellopontine angle should be considered for a combination of endovascular embolization, micro-surgical resection and SRS. Considering the fact that incompletely obliterated lesions (even when reduced in size) could still cause lethal hemorrhages, additional treatment, including repeat SRS and surgical resection should be considered when complete obliteration is not achieved by first SRS. Patients with brainstem AVM require continued clinical and radiological observation and follow-up after SRS, well after angiographic obliteration has been confirmed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Gamma knife radiosurgery of radiation-induced intracranial tumors: Local control, outcomes, and complications

    International Nuclear Information System (INIS)

    Jensen, Ashley W.; Brown, Paul D.; Pollock, Bruce E.; Stafford, Scott L.; Link, Michael J.; Garces, Yolanda I.; Foote, Robert L.; Gorman, Deborah A.; Schomberg, Paula J.

    2005-01-01

    Purpose: To determine local control (LC) and complication rates for patients who underwent radiosurgery for radiation-induced intracranial tumors. Methods and Materials: Review of a prospectively maintained database (2,714 patients) identified 16 patients (20 tumors) with radiation-induced tumors treated with radiosurgery between 1990 and 2004. Tumor types included typical meningioma (n = 17), atypical meningioma (n = 2), and schwannoma (n 1). Median patient age at radiosurgery was 47.5 years (range, 27-70 years). The median tumor margin dose was 16 Gy (range, 12-20 Gy). Median follow-up was 40.2 months (range, 10.8-146.2 months). Time-to-event outcomes were calculated with Kaplan-Meier estimates. Results: Three-year and 5-year LC rates were 100%. Three-year and 5-year overall survival rates were 92% and 80%, respectively. Cause-specific survival rates at 3 and 5 years were 100%. Three patients died: 1 had in-field progression 65.1 months after radiosurgery and later died of the tumor, 1 died of progression of a preexisting brain malignancy, and 1 died of an unrelated cause. One patient had increased seizure activity that correlated with development of edema seen on neuroimaging. Conclusions: LC, survival, and complication rates in our series are comparable to those in previous reports of radiosurgery for intracranial meningiomas. Also, LC rates with radiosurgery are at least comparable to those of surgical series for radiation-induced meningiomas. Radiosurgery is a safe and effective treatment option for radiation-induced intracranial tumors, most of which are typical meningiomas

  8. Vagus nerve stimulation and stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Kawai, Kensuke

    2005-01-01

    Vagus nerve stimulation and stereotactic radiosurgery represent novel and less invasive therapeutics for medically intractable epilepsy. Chronic stimulation of the left vagus nerve with implanted generator and electrodes inhibits seizure susceptibility of the cerebral cortices. While the underlying mechanisms of the effect remains to be further elucidated, the efficacy and safety of vagus nerve stimulation have been established by randomized clinical trials in the United States and European countries. It has been widely accepted as a treatment option for patients with medically intractable epilepsy and for whom brain surgery is not indicated. The primary indication of vagus nerve stimulation in the clinical trials was localization-related epilepsy in adult patients but efficacy in a wide range of patient groups such as generalized epilepsy and children has been reported. Improvements in daytime alertness, mood, higher cognitive functions and overall quality of life have been reported other than the effect on epileptic seizures. Since the devices are not approved for clinical use in Japan by the Health, Labor and Welfare Ministry, there exist barriers to provide this treatment to patients at present. Stereotactic radiosurgery has been used for temporal lobe epilepsy and hypothalamic hamartoma, but it is still controversial whether the therapy is more effective and less invasive than brain surgery. Promising results of gamma knife radiosurgery for medically intractable temporal lobe epilepsy with unilateral hippocampal sclerosis have been reported essentially from one French center. Results from others were not as favorable. There seems to be an unignorable risk of brain edema and radiation necrosis when the delivered dose over the medial temporal structures is high enough to abolish epileptic seizures. A randomized clinical trial comparing different marginal doses is ongoing in the United States. Clinical trials like this, technical advancement and standardization

  9. Evaluation of time, attendance of medical staff, and resources during stereotactic radiotherapy/radiosurgery. QUIRO-DEGRO trial

    Energy Technology Data Exchange (ETDEWEB)

    Zabel-du Bois, A.; Milker-Zabel, S.; Debus, J. [Heidelberg Univ. (Germany). Dept. of Radiotherapy and Radiooncology; Henzel, M.; Engenhart-Cabillic, R. [Marburg Univ. (Germany). Dept. of Radiotherapy and Radiation Oncology; Popp, W. [Prime Networks AG, Basel (Switzerland); Sack, H. [Essen Univ. (Germany). Dept. of Radiation Oncology

    2012-09-15

    Background: The German Society of Radiation Oncology ('Deutsche Gesellschaft fuer Radioonkologie', DEGRO) initiated a multicenter trial to develop and evaluate adequate modules to assert core processes and subprocesses in radiotherapy. The aim of this prospective evaluation was to methodical assess the required resources (technical equipment and medical staff) for stereotactic radiotherapy/radiosurgery. Material and methods: At two radiotherapy centers of excellence (University Hospitals of Heidelberg and Marburg/Giessen), the manpower and time required for the implementation of intra- and extracranial stereotactic radiotherapy was prospectively collected consistently over a 3-month period. The data were collected using specifically developed process acquisition tools and standard forms and were evaluated using specific process analysis tools. Results: For intracranial (extracranial) fractionated stereotactic radiotherapy (FSRT) and radiosurgery (RS), a total of 1,925 (270) and 199 (36) records, respectively, could be evaluated. The approximate time needed to customize the immobilization device was median 37 min (89 min) for FRST and 31 min (26 min) for RS, for the contrast enhanced planning studies 22 and 27 min (25 and 28 min), for physical treatment planning 122 and 59 min (187 and 27 min), for the first and routine radiotherapy sessions for FSRT 40 and 13 min (58 and 31 min), respectively. The median time needed for the RS session was 58 min (45 min). The corresponding minimal manpower needed was 2 technicians for customization of the immobilization device, 2.5 technicians and 1 consultant for the contrast-enhanced planning studies, 1 consultant, 0.5 resident and 0.67 medical physics expert (MPE) for physical treatment planning, as well as 1 consultant, 0.5 resident, and 2.5 technicians for the first radiotherapy treatment and 2.33 technicians for routine radiotherapy sessions. Conclusion: For the first time, the resource requirements for a

  10. Stereotactic radiosurgery in the palliative treatment of brain metastases

    International Nuclear Information System (INIS)

    Faria, Sergio L.; Souhami, Luis; Bahary, Jean-Paul; Clark, Brenda; Adamson, Nelson; Podgorsak, Ervin B.; Caron, Jean-Louis; Villemure, Jean-Guy; Olivier, Andre

    1995-01-01

    Between October, 1988 and November, 1993, 57 patients with metastatic brain disease underwent stereotactic radiosurgery at McGill University, canada. Four patients were excluded from this analysis leaving a total of 53 evaluable patients (with 57 lesions). Radiosurgery was performed with the dynamic rotation technique which uses an isocentric, 10 MV, linear accelerator. A median dose of 1,800 c Gy was given in a single session. In 89% of the cases radiosurgery was used after failure to conventional brain radiotherapy. With a median follow-up of 6 months, the response rate was 65% . Treatments were well tolerated and only 4 patients (7%) developed late complications related to the therapy, with one patient requiring a surgical resection of an area of radionecrose. Radiosurgery appears to be and effective and safe treatment for selected patients with metastatic brain disease, recurrent post-conventional radiotherapy. Its value as a single treatment modality for patients with isolated brain metastasis is now being studied in prospective trials. (author). 29 refs., 4 figs., 4 tabs

  11. Radiocromic film, TLD, OSL and 'Paracas Phantom' by dosimetric intercomparation in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Paucar Jauregui, R.; Condori Marcos, P.; Vidarte Garcia, F.

    2008-01-01

    Full text: In Peru, one deals to patients with arteriovenous malformations or cerebral tumors by means of stereotactic radiosurgery, using fine photon beams of high energy of 6 MeV, generated by a linear accelerator Varian 2100 Clinac CD of the Complejo Hospitalario San Pablo in Lima, Peru. In this work we describes the 'Dosimetric Intercomparation System of the Quality Assurance Program in Stereotactic Radiosurgery of the Complejo Hospitalario San Pablo (DIS)'. The DIS allows to guarantee application of the doses with high accuracy. It shows the good performance of the Local DIS's components: dosimetry of radiocromics films, dosimetry termoluminiscent (TLD), dosimetry of optically stimulated luminescence (OSL) and an anthropomorphic phantom of head constructed locally, denominated 'Paracas Phantom'. Also, in the International DIS practiced with The University of Texas Md Anderson Cancer Center, stands out results within the ranges: a) Dose to the center of the target (RDS/Institution): 0,95-1,05; b) Treated volumen (Measured/Institution): 0,75 - 1,05; c) Ratio of measure treated volume to target volume: 1,00 - 2,00; and d) Minimum dose to target (Minimum dose/Prescription dose): >0,90. It concludes that the DIS is important for the good decision making on the radiological safety of the patients dealt with stereotactic radiosurgery. (author)

  12. Frameless stereotactic radiosurgery of a solitary liver metastasis using active breathing control and stereotactic ultrasound

    International Nuclear Information System (INIS)

    Boda-Heggemann, J.; Walter, C.; Mai, S.; Dobler, B.; Wenz, F.; Lohr, F.; Dinter, D.

    2006-01-01

    Background and purpose: radiosurgery of liver metastases is effective but a technical challenge due to respiration-induced movement. The authors report on the initial experience of the combination of active breathing control (ABC registered ) with stereotactic ultrasound (B-mode acquisition and targeting [BAT registered ]) for frameless radiosurgery. Patient and methods: a patient with a solitary, inoperable liver metastasis from cholangiocellular carcinoma is presented. ABC registered was used for tumor/liver immobilization. Tumor/liver position was controlled and corrected using ultrasound (BAT registered ). The tumor was irradiated with a single dose of 24 Gy. Results: using ABC registered , the motion of the tumor was significantly reduced and the overall positioning error was registered allowed a rapid localization of the lesion during breath hold which could be performed without difficulties for 20 s. Overall treatment time was acceptable (30 min). Conclusion: frameless stereotactic radiotherapy with the combination of ABC registered and BAT registered allows the delivery of high single doses to targets accessible to ultrasound with high precision comparable to a frame-based approach. (orig.)

  13. Stereotactic radiosurgery versus stereotactic radiotherapy for patients with vestibular schwannoma: a Leksell Gamma Knife Society 2000 debate.

    Science.gov (United States)

    Linskey, Mark E

    2013-12-01

    By definition, the term "radiosurgery" refers to the delivery of a therapeutic radiation dose in a single fraction, not simply the use of stereotaxy. Multiple-fraction delivery is better termed "stereotactic radiotherapy." There are compelling radiobiological principles supporting the biological superiority of single-fraction radiation for achieving an optimal therapeutic response for the slowly proliferating, late-responding, tissue of a schwannoma. It is axiomatic that complication avoidance requires precise three-dimensional conformality between treatment and tumor volumes. This degree of conformality can only be achieved through complex multiisocenter planning. Alternative radiosurgery devices are generally limited to delivering one to four isocenters in a single treatment session. Although they can reproduce dose plans similar in conformality to early gamma knife dose plans by using a similar number of isocenters, they cannot reproduce the conformality of modern gamma knife plans based on magnetic resonance image--targeted localization and five to 30 isocenters. A disturbing trend is developing in which institutions without nongamma knife radiosurgery (GKS) centers are championing and/or shifting to hypofractionated stereotactic radiotherapy for vestibular schwannomas. This trend appears to be driven by a desire to reduce complication rates to compete with modern GKS results by using complex multiisocenter planning. Aggressive advertising and marketing from some of these centers even paradoxically suggests biological superiority of hypofractionation approaches over single-dose radiosurgery for vestibular schwannomas. At the same time these centers continue to use the term radiosurgery to describe their hypofractionated radiotherapy approach in an apparent effort to benefit from a GKS "halo effect." It must be reemphasized that as neurosurgeons our primary duty is to achieve permanent tumor control for our patients and not to eliminate complications at the

  14. The value of image coregistration during stereotactic radiosurgery.

    Science.gov (United States)

    Koga, T; Maruyama, K; Igaki, H; Tago, M; Saito, N

    2009-05-01

    Coregistration of any neuroimaging studies into treatment planning for stereotactic radiosurgery became easily applicable using the Leksell Gamma Knife 4C, a new model of gamma knife. The authors investigated the advantage of this image processing. Since installation of the Leksell Gamma Knife 4C at the authors' institute, 180 sessions of radiosurgery were performed. Before completion of planning, coregistration of frameless images of other modalities or previous images was considered to refine planning. Treatment parameters were compared for planning before and after refinement by use of coregistered images. Coregistered computed tomography clarified the anatomical structures indistinct on magnetic resonance imaging. Positron emission tomography visualized lesions disclosing metabolically high activity. Coregistration of prior imaging distinguished progressing lesions from stable ones. Diffusion-tensor tractography was integrated for lesions adjacent to the corticospinal tract or the optic radiation. After refinement of planning in 36 sessions, excess treated volume decreased (p = 0.0062) and Paddick conformity index improved (p < 0.001). Maximal dose to the white matter tracts was decreased (p < 0.001). Image coregistration provided direct information on anatomy, metabolic activity, chronological changes, and adjacent critical structures. This gathered information was sufficiently informative during treatment planning to supplement ambiguous information on stereotactic images, and was useful especially in reducing irradiation to surrounding normal structures.

  15. Stereotactic radiosurgery may contribute to overall survival for patients with recurrent head and neck carcinoma

    International Nuclear Information System (INIS)

    Kawaguchi, Koji; Sato, Kengo; Horie, Akihisa; Iketani, Susumu; Yamada, Hiroyuki; Nakatani, Yasunori; Sato, Junichi; Hamada, Yoshiki

    2010-01-01

    The aim of this study is to examine the effect of stereotactic radiosurgery (SRS) in the treatment of advanced, recurrent lesions for head and neck carcinoma both with and without lymph node involvement. Between April 2006 and July 2007, 22 patients (mean age 67 years) with advanced, recurrent head and neck carcinoma were treated with stereotactic radiosurgery. All of the patients except one had biopsy confirmed disease prior to stereotactic radiosurgery. Patients included 3 rT2, 8 rT3, and 9 rT4; 8 of the patients had lymph node metastases. Marginal SRS doses were 20-42 Gy delivered in two to five fractions. Starting one month after SRS, all patients received S-1 oral chemotherapy for one year. At an overall median follow-up of 24 months (range, 4-39 months), for the 14 locally recurrent patients without lymph node metastases, 9 patients (64.3%) had a complete response (CR), 1 patient (7.1%) had a partial response (PR), 1 patient (7.1%) had stable disease (SD), and 3 patients (21.4%) had progressive disease (PD). For the 8 patients with lymph node metastases, 1 patient with a single retropharyngeal (12.5%) had CR; the remaining 7 patients (87.5%) all progressed. Nine patients have died from their cancer. The overall actuarial 2-year survival for the patients with and without lymph node metastases is 12.5% and 78.6%, respectively. These results show the benefit of stereotactic radiosurgery salvage treatment for advanced, recurrent lesions, without lymph node metastases in previously irradiated head and neck cancer

  16. A theoretical analysis of hemodynamic and biomechanical alterations in intracranial AVMs after radiosurgery

    International Nuclear Information System (INIS)

    Lo, E.H.

    1993-01-01

    Stereotactic radiosurgery is being increasingly used to treat intracranial arteriovenous malformations (AVMs). However, successful radiosurgery may involve latent periods of 1-2 years prior to AVM obliteration. This latent period include states of altered flow patterns that may not influence hemorrhage probabilities. The probability of hemorrhage is likely to be related to the degree of biomechanical stress across the AVM shunt walls. This paper describes a theoretical analysis of the altered hemodynamics and biomechanical stresses within AVM shunts post-radiosurgery. The mathematical model is comprised of linked flow compartments that represent the AVM and adjacent normal vasculature. As obliteration of the irradiated shunts occurs, changes in flow rates and pressure gradients are calculated based on first order fluid dynamics. Stress on the AVM shunt walls is calculated based on tangential forces due to intramural pressure. Two basic models are presented: a distribution of shunts with fixed thin walls subject to step-function obliteration, and a distribution of shunts subject to luminal obliteration from slowly thickening walls. Variations on these models are analyzed, including sequential, selective and random shunt obliteration, and uniform or Poisson distributions of shunt radii. Model I reveals that the range of pressure alterations in the radiosurgically-treated AVM include the possibility of transient increases in the total biomechanical stress within the shunt walls prior to obliteration. Model II demonstrates that uniform luminal narrowing via thickened walls should lead to reduced transmural stresses. The precise temporal pattern of AVM flow decrease and biomechanical stress reduction depends on the selection of shunts that are obliterated. 34 refs., 5 figs., 1 tab

  17. Management of intracranial arteriovenous malformations

    International Nuclear Information System (INIS)

    Miyamoto, Susumu; Takahashi, Jun C.

    2008-01-01

    Intracranial arteriovenous malformations (AVMs) are congenital lesions that can cause serious neurological deficits or even death. They can manifest as intracranial hemorrhage, epileptic seizure, or other symptoms such as headache or tinnitus. They are detected by computed tomography or magnetic resonance imaging. Recently there have been significant developments in the management of AVMs. In this paper, the authors represent an overview of the epidemiology of AVMs and the existing treatment strategies. AVMs are ideally excised by standard microsurgical techniques. The grading scale which was proposed by Spetzler and Martin is widely used to estimate the risk of direct surgery. Stereotactic radiosurgery such as that using a gamma knife is very useful for small lesions located in eloquent areas. Technological advances in endovascular surgery have provided new alternatives in the treatment of AVMs. Currently indications for embolization can be divided into presurgical embolization in large AVMs to occlude deep arterial feeding vessels and embolization before stereotactic radiosurgery to reduce the size of the nidus. Palliative embolization can be also applied for patients with large, inoperable AVMs who are suffering from progressive neurological deficits secondary to venous hypertension and/or arterial steal phenomenon. (author)

  18. Management of intracranial arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, Susumu; Takahashi, Jun C [National Cardiovascular Center, Suita, Osaka (Japan)

    2008-10-15

    Intracranial arteriovenous malformations (AVMs) are congenital lesions that can cause serious neurological deficits or even death. They can manifest as intracranial hemorrhage, epileptic seizure, or other symptoms such as headache or tinnitus. They are detected by computed tomography or magnetic resonance imaging. Recently there have been significant developments in the management of AVMs. In this paper, the authors represent an overview of the epidemiology of AVMs and the existing treatment strategies. AVMs are ideally excised by standard microsurgical techniques. The grading scale which was proposed by Spetzler and Martin is widely used to estimate the risk of direct surgery. Stereotactic radiosurgery such as that using a gamma knife is very useful for small lesions located in eloquent areas. Technological advances in endovascular surgery have provided new alternatives in the treatment of AVMs. Currently indications for embolization can be divided into presurgical embolization in large AVMs to occlude deep arterial feeding vessels and embolization before stereotactic radiosurgery to reduce the size of the nidus. Palliative embolization can be also applied for patients with large, inoperable AVMs who are suffering from progressive neurological deficits secondary to venous hypertension and/or arterial steal phenomenon. (author)

  19. Development of stereotactic radiosurgery using carbon beams (carbon-knife)

    Science.gov (United States)

    Keawsamur, Mintra; Matsumura, Akihiko; Souda, Hikaru; Kano, Yosuke; Torikoshi, Masami; Nakano, Takashi; Kanai, Tatsuaki

    2018-02-01

    The aim of this research is to develop a stereotactic-radiosurgery (SRS) technique using carbon beams to treat small intracranial lesions; we call this device the carbon knife. A 2D-scanning method is adapted to broaden a pencil beam to an appropriate size for an irradiation field. A Mitsubishi slow extraction using third order resonance through a rf acceleration system stabilized by a feed-forward scanning beam using steering magnets with a 290 MeV/u initial beam energy was used for this purpose. Ridge filters for spread-out Bragg peaks (SOBPs) with widths of 5 mm, 7.5 mm, and 10 mm were designed to include fluence-attenuation effects. The collimator, which defines field shape, was used to reduce the lateral penumbra. The lateral-penumbra width at the SOBP region was less than 2 mm for the carbon knife. The penumbras behaved almost the same when changing the air gap, but on the other hand, increasing the range-shifter thickness mostly broadened the lateral penumbra. The physical-dose rates were approximate 6 Gy s-1 and 4.5 Gy s-1 for the 10  ×  10 mm2 and 5  ×  5 mm2 collimators, respectively.

  20. The geometric accuracy of frameless stereotactic radiosurgery using a 6D robotic couch system

    Energy Technology Data Exchange (ETDEWEB)

    Takakura, T; Nakata, M; Yano, S; Fujimoto, T [Division of Clinical Radiology Service, Kyoto University Hospital, Kyoto (Japan); Mizowaki, T; Miyabe, Y; Nakamura, M; Hiraoka, M [Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Kyoto (Japan)], E-mail: toru1@kuhp.kyoto-u.ac.jp

    2010-01-07

    The aim of this paper is to assess the overall geometric accuracy of the Novalis system using the Robotic Tilt Module in terms of the uncertainty in frameless stereotactic radiotherapy. We analyzed the following three metrics: (1) the correction accuracy of the robotic couch, (2) the uncertainty of the isocenter position with gantry and couch rotation, and (3) the shift in position between the isocenter and central point detected with the ExacTrac x-ray system. Based on the concept of uncertainty, the overall accuracy was calculated from these values. The accuracy in positional correction with the robotic couch was 0.07 {+-} 0.22 mm, the positional shift of the isocenter associated with gantry rotation was 0.35 mm, the positional shift of the isocenter associated with couch rotation was 0.38 mm and the difference in position between the isocenter and the ExacTrac x-ray system was 0.30 mm. The accuracy of intracranial stereotactic radiosurgery with the Novalis system in our clinic was 0.31 {+-} 0.77 mm. The overall geometric accuracy based on the concept of uncertainty was 0.31 {+-} 0.77 mm, which is within the tolerance given in the American Association of Physicists in Medicine report no. 54.

  1. The geometric accuracy of frameless stereotactic radiosurgery using a 6D robotic couch system

    International Nuclear Information System (INIS)

    Takakura, T; Nakata, M; Yano, S; Fujimoto, T; Mizowaki, T; Miyabe, Y; Nakamura, M; Hiraoka, M

    2010-01-01

    The aim of this paper is to assess the overall geometric accuracy of the Novalis system using the Robotic Tilt Module in terms of the uncertainty in frameless stereotactic radiotherapy. We analyzed the following three metrics: (1) the correction accuracy of the robotic couch, (2) the uncertainty of the isocenter position with gantry and couch rotation, and (3) the shift in position between the isocenter and central point detected with the ExacTrac x-ray system. Based on the concept of uncertainty, the overall accuracy was calculated from these values. The accuracy in positional correction with the robotic couch was 0.07 ± 0.22 mm, the positional shift of the isocenter associated with gantry rotation was 0.35 mm, the positional shift of the isocenter associated with couch rotation was 0.38 mm and the difference in position between the isocenter and the ExacTrac x-ray system was 0.30 mm. The accuracy of intracranial stereotactic radiosurgery with the Novalis system in our clinic was 0.31 ± 0.77 mm. The overall geometric accuracy based on the concept of uncertainty was 0.31 ± 0.77 mm, which is within the tolerance given in the American Association of Physicists in Medicine report no. 54.

  2. Microsurgical resection of incompletely obliterated intracranial arteriovenous malformations following stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Chang, S.D.; Steinberg, G.K.; Levy, R.P.; Marks, M.P.; Frankel, K.A.; Shuster, D.L.; Marcellus, M.L.

    1998-01-01

    Radiosurgery is effective in obliterating small arteriovenous malformations (AVMs), but less successful in thrombosing larger AVMs. This study reviewed patients who underwent surgical resection of their large AVMs following failed radiosurgical obliteration. AVMs from 36 patients (aged 7 to 64 years, mean 29.9) were surgically resected 1 to 11 years after radiosurgery. Initial AVM volumes were 0.7 to 117 cm 3 (mean 21.6 cm 3 ), and radiosurgical doses ranged from 4.6 to 45 Gray equivalent (GyE) (mean 21.1 GyE). Thirty AVMs (83%) were located in eloquent tissue. Venous drainage was deep (14), superficial (13), or both (9). Spetzler grades were II (2), III (12), IV (18), and V (4). Nine patients suffered rehemorrhage after radiosurgery but prior to surgery, while three patients developed radiation necrosis. Twenty-seven patients underwent endovascular embolization prior to surgery. During microsurgical resection, the AVMs were found to be significantly less vascular and more easily resected, compared to AVMs in patients who had not received radiosurgery. Histology showed endothelial proliferation with hyaline and mineralization in vessel walls. Partial or complete thrombosis of some AVM vessels, and evidence of vessel and brain necrosis were noted in many cases. Clinical outcome was excellent or good in 34 cases, with two patients dying of rebleeding from residual AVM. Five patients were neurologically worse following microsurgical resection. Final outcome was largely related to the pretreatment grade. Radiosurgery several years prior to surgical resection appears useful in treating unusually large and complex AVMs. (author)

  3. Stereotactic radiosurgery using the gamma knife for acoustic neuromas

    International Nuclear Information System (INIS)

    Foote, Robert L.; Coffey, Robert J.; Swanson, Jerry W.; Harner, Stephen G.; Beatty, Charles W.; Kline, Robert W.; Stevens, Lorna N.; Hu, Theresa C.

    1995-01-01

    Purpose: To assess the efficacy and toxicity of stereotactic radiosurgery using the gamma knife for acoustic neuromas. Methods and Materials: Between January 1990 and January 1993, 36 patients with acoustic neuromas were treated with stereotactic radiosurgery using the gamma knife. The median maximum tumor diameter was 21 mm (range: 6-32 mm). Tumor volumes encompassed within the prescribed isodose line varied from 266 to 8,667 mm 3 (median: 3,135 mm 3 ). Tumors ≤ 20 mm in maximum diameter received a dose of 20 Gy to the margin, tumors between 21 and 30 mm received 18 Gy, and tumors > 30 mm received 16 Gy. The dose was prescribed to the 50% isodose line in 31 patients and to the 45%, 55%, 60%, 70%, and 80% isodose line in one patient each. The median number of isocenters per tumor was 5 (range: 1-12). Results: At a median follow-up of 16 months (range: 2.5-36 months), all patients were alive. Thirty-five patients had follow-up imaging studies. Nine tumors (26%) were smaller, and 26 tumors (74%) were unchanged. No tumor had progressed. The 1- and 2-year actuarial incidences of facial neuropathy were 52.2% and 66.5%, respectively. The 1- and 2-year actuarial incidences of trigeminal neuropathy were 33.7% and 58.9%, respectively. The 1- and 2-year actuarial incidence of facial or trigeminal neuropathy (or both) was 60.8% and 81.7%, respectively. Multivariate analysis revealed that the following were associated with the time of onset or worsening of facial weakness or trigeminal neuropathy: (a) patients five isocenters. The 1- and 2-year actuarial rates of preservation of useful hearing (Gardner-Robertson class I or II) were 100% and 41.7% ± 17.3, respectively. Conclusion: Stereotactic radiosurgery using the gamma knife provides short-term control of acoustic neuromas when a dose of 16 to 20 Gy to the tumor margin is used. Preservation of useful hearing can be accomplished in a significant proportion of patients

  4. Stereotactic radiotherapy and radiosurgery in pediatric patients: analysis of indications and outcome

    DEFF Research Database (Denmark)

    Mirza, Bilal; Mønsted, Anne; Jensen, Josephine Harding

    2010-01-01

    We describe indications, outcomes, and risk profiles of fractionated stereotactic radiotherapy (SRT) and single fraction "radiosurgery" (SRS) in pediatric patients compared to the adult population and evaluate the causal role of SRS and SRT in inducing new neurological complications....

  5. Is it sufficient to repeat LINEAR accelerator stereotactic radiosurgery in choroidal melanoma?

    Science.gov (United States)

    Furdova, A; Horkovicova, K; Justusova, P; Sramka, M

    One day session LINAC based stereotactic radiosurgery (SRS) at LINAC accelerator is a method of "conservative" attitude to treat the intraocular malignant uveal melanoma. We used model Clinac 600 C/D Varian (system Aria, planning system Corvus version 6.2 verification IMRT OmniPro) with 6 MeV X by rigid immobilization of the eye to the Leibinger frame. The stereotactic treatment planning after fusion of CT and MRI was optimized according to the critical structures (lens, optic nerve, also lens and optic nerve at the contralateral side, chiasm). The first plan was compared and the best plan was applied for therapy at C LINAC accelerator. The planned therapeutic dose was 35.0 Gy by 99 % of DVH (dose volume histogram). In our clinical study in the group of 125 patients with posterior uveal melanoma treated with SRS, in 2 patients (1.6 %) was repeated SRS indicated. Patient age of the whole group ranged from 25 to 81 years with a median of 54 TD was 35.0 Gy. In 2 patients after 5 year interval after stereotactic radiosurgery for uveal melanoma stage T1, the tumor volume increased to 50 % of the primary tumor volume and repeated SRS was necessary. To find out the changes in melanoma characteristics after SRS in long term interval after irradiation is necessary to follow up the patient by an ophthalmologist regularly. One step LINAC based stereotactic radiosurgery with a single dose 35.0 Gy is one of treatment options to treat T1 to T3 stage posterior uveal melanoma and to preserve the eye globe. In some cases it is possible to repeat the SRS after more than 5 year interval (Fig. 8, Ref. 23).

  6. Solid craniopharyngiomas treated by stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Backlund, E.-O.

    1979-01-01

    The radiological changes of solid craniopharyngiomas treated by stereotactic radiosurgery have been followed. Nine cases are considered, the patients having received gamma radiation treatment with a dose distribution permitting no part of the tumour to receive doses less than 2-3 Gy. Target doses were 20 to 50 Gy. Tumour shrinkage was registered and no complications which could be attributed with certainty to the irradiation were encountered. The results did not allow an optimal single dose to be determined with accuracy but vaguely indicated that lower doses than those used are sufficient for desired effect on the tumour without jeopardizing its surroundings. (Auth./C.F.)

  7. SU-D-BRA-03: Analysis of Systematic Errors with 2D/3D Image Registration for Target Localization and Treatment Delivery in Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Xu, H; Chetty, I; Wen, N

    2016-01-01

    Purpose: Determine systematic deviations between 2D/3D and 3D/3D image registrations with six degrees of freedom (6DOF) for various imaging modalities and registration algorithms on the Varian Edge Linac. Methods: The 6DOF systematic errors were assessed by comparing automated 2D/3D (kV/MV vs. CT) with 3D/3D (CBCT vs. CT) image registrations from different imaging pairs, CT slice thicknesses, couch angles, similarity measures, etc., using a Rando head and a pelvic phantom. The 2D/3D image registration accuracy was evaluated at different treatment sites (intra-cranial and extra-cranial) by statistically analyzing 2D/3D pre-treatment verification against 3D/3D localization of 192 Stereotactic Radiosurgery/Stereotactic Body Radiation Therapy treatment fractions for 88 patients. Results: The systematic errors of 2D/3D image registration using kV-kV, MV-kV and MV-MV image pairs using 0.8 mm slice thickness CT images were within 0.3 mm and 0.3° for translations and rotations with a 95% confidence interval (CI). No significant difference between 2D/3D and 3D/3D image registrations (P>0.05) was observed for target localization at various CT slice thicknesses ranging from 0.8 to 3 mm. Couch angles (30, 45, 60 degree) did not impact the accuracy of 2D/3D image registration. Using pattern intensity with content image filtering was recommended for 2D/3D image registration to achieve the best accuracy. For the patient study, translational error was within 2 mm and rotational error was within 0.6 degrees in terms of 95% CI for 2D/3D image registration. For intra-cranial sites, means and std. deviations of translational errors were −0.2±0.7, 0.04±0.5, 0.1±0.4 mm for LNG, LAT, VRT directions, respectively. For extra-cranial sites, means and std. deviations of translational errors were - 0.04±1, 0.2±1, 0.1±1 mm for LNG, LAT, VRT directions, respectively. 2D/3D image registration uncertainties for intra-cranial and extra-cranial sites were comparable. Conclusion: The Varian

  8. SU-D-BRA-03: Analysis of Systematic Errors with 2D/3D Image Registration for Target Localization and Treatment Delivery in Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Xu, H [Wayne State University, Detroit, MI (United States); Chetty, I; Wen, N [Henry Ford Health System, Detroit, MI (United States)

    2016-06-15

    Purpose: Determine systematic deviations between 2D/3D and 3D/3D image registrations with six degrees of freedom (6DOF) for various imaging modalities and registration algorithms on the Varian Edge Linac. Methods: The 6DOF systematic errors were assessed by comparing automated 2D/3D (kV/MV vs. CT) with 3D/3D (CBCT vs. CT) image registrations from different imaging pairs, CT slice thicknesses, couch angles, similarity measures, etc., using a Rando head and a pelvic phantom. The 2D/3D image registration accuracy was evaluated at different treatment sites (intra-cranial and extra-cranial) by statistically analyzing 2D/3D pre-treatment verification against 3D/3D localization of 192 Stereotactic Radiosurgery/Stereotactic Body Radiation Therapy treatment fractions for 88 patients. Results: The systematic errors of 2D/3D image registration using kV-kV, MV-kV and MV-MV image pairs using 0.8 mm slice thickness CT images were within 0.3 mm and 0.3° for translations and rotations with a 95% confidence interval (CI). No significant difference between 2D/3D and 3D/3D image registrations (P>0.05) was observed for target localization at various CT slice thicknesses ranging from 0.8 to 3 mm. Couch angles (30, 45, 60 degree) did not impact the accuracy of 2D/3D image registration. Using pattern intensity with content image filtering was recommended for 2D/3D image registration to achieve the best accuracy. For the patient study, translational error was within 2 mm and rotational error was within 0.6 degrees in terms of 95% CI for 2D/3D image registration. For intra-cranial sites, means and std. deviations of translational errors were −0.2±0.7, 0.04±0.5, 0.1±0.4 mm for LNG, LAT, VRT directions, respectively. For extra-cranial sites, means and std. deviations of translational errors were - 0.04±1, 0.2±1, 0.1±1 mm for LNG, LAT, VRT directions, respectively. 2D/3D image registration uncertainties for intra-cranial and extra-cranial sites were comparable. Conclusion: The Varian

  9. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance.

    Science.gov (United States)

    Gagnon, Jean-Christophe; Thériault, Dany; Guillot, Mathieu; Archambault, Louis; Beddar, Sam; Gingras, Luc; Beaulieu, Luc

    2012-01-01

    To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S(c,p)) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 × 10 cm(2) field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S(c,p) within 1.4% and 0.7% for 5 and 35 mm diameter cone, respectively. Furthermore

  10. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Jean-Christophe; Theriault, Dany; Guillot, Mathieu; Archambault, Louis; Beddar, Sam; Gingras, Luc; Beaulieu, Luc [Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Department of Radiation Physics, Unit 94, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States); Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada)

    2012-01-15

    Purpose: To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. Methods: The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S{sub c,p}) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Results: Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 x 10 cm{sup 2} field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S{sub c,p} within 1.4% and 0.7% for 5 and 35 mm diameter cone

  11. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance

    International Nuclear Information System (INIS)

    Gagnon, Jean-Christophe; Theriault, Dany; Guillot, Mathieu; Archambault, Louis; Beddar, Sam; Gingras, Luc; Beaulieu, Luc

    2012-01-01

    Purpose: To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. Methods: The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S c,p ) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Results: Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 x 10 cm 2 field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S c,p within 1.4% and 0.7% for 5 and 35 mm diameter cone, respectively

  12. Hypofractionated Stereotactic Radiosurgery in a Large Bilateral Thalamic and Basal Ganglia Arteriovenous Malformation

    Directory of Open Access Journals (Sweden)

    Janet Lee

    2013-01-01

    Full Text Available Purpose. Arteriovenous malformations (AVMs in the basal ganglia and thalamus have a more aggressive natural history with a higher morbidity and mortality than AVMs in other locations. Optimal treatment—complete obliteration without new neurological deficits—is often challenging. We present a patient with a large bilateral basal ganglia and thalamic AVM successfully treated with hypofractionated stereotactic radiosurgery (HFSRS with intensity modulated radiotherapy (IMRT. Methods. The patient was treated with hypofractionated stereotactic radiosurgery to 30 Gy at margin in 5 fractions of 9 static fields with a minimultileaf collimator and intensity modulated radiotherapy. Results. At 10 months following treatment, digital subtraction angiography showed complete obliteration of the AVM. Conclusions. Large bilateral thalamic and basal ganglia AVMs can be successfully treated with complete obliteration by HFSRS with IMRT with relatively limited toxicity. Appropriate caution is recommended.

  13. The current role of Gamma Knife radiosurgery in the management of intracranial haemangiopericytoma.

    Science.gov (United States)

    Spina, Alfio; Boari, Nicola; Gagliardi, Filippo; Donofrio, Carmine A; Franzin, Alberto; Mortini, Pietro

    2016-04-01

    Haemangiopericytomas (HPCs) are rare tumours characterised by aggressive behaviour with tendency to local recurrence and to metastasise. WHO grade II and grade III tumours show different progression-free survival and overall survival rates. Gross total tumour resection is still considered the treatment of choice. Adjuvant radiation therapies represent an option in the treatment strategy regardless the extent of resection. Based on this consideration, Gamma Knife radiosurgery has been introduced either as a primary treatment or as an adjuvant treatment for residual or recurrent tumours. A systematic search was performed on PubMed, Web of Science and Google Scholar for clinical series reporting Gamma Knife radiosurgery, Cyberknife and Linear Accelerator (LINAC) for the management of intracranial HPCs. Fourteen studies focusing on the effects of Gamma Knife radiosurgery for intracranial HPCs were included. Four studies reported data on Cyberknife radiosurgery and LINAC. A total of 208 patients harbouring 366 tumours have been reported. Patient's features, radiosurgical treatment characteristics and follow-up data of the pertinent literature have been critically revised. Gamma Knife radiosurgery and the other radiosurgical techniques represent a feasible and effective therapy in the management of HPCs. Tumour control and survival rate are comparable to those reported for radiotherapy. Further studies should be focused to define the exact role of Gamma Knife radiosurgery in the management of HPCs.

  14. Accuracy of target localisation and alignment in stereotactic radiosurgery at Royal Prince Alfred Hospital

    International Nuclear Information System (INIS)

    Downes, S.

    1996-01-01

    Full text: Over the last 30 years, stereotactic radiosurgery has become an effective clinical tool in the treatment of intra-cranial lesions. The use of high doses to a specific target volume in a single fraction and the proximity of critical organs requires very accurate geometric localisation of the various cranial structures (using CT, MRI and angiography imaging) and accurate alignment of the target volume prior to treatment. The purpose of this paper was to determine the accuracy of localising cranial structures using computed tomography and angiographic imaging modalities and to determine the accuracy of aligning the treatment isocentre to the specified coordinates. The sum of these two errors will give the total deviation of the treated target from the actual target. Measurements were made using an anthropomorphic (ART) phantom of an adult male and a cerrobend target. The ART phantom was immobilised using the Brown-Roberts-Wells (BRW) ring. The cerrobend target was inserted into the skull at 10 different positions. Each of these 10 positions were scanned using CT and angiographic imaging and localised using the stereotactic planning software. For each test position, the ART phantom was placed on the treatment couch and aligned to the treatment coordinates determined using localisation (CT and angiography). A-P and lateral port films were then made of the target. The distance between the centre of the cerrobend target (intended target) and the centre of radiation (actual target) was the total error in localisation and alignment of the target. For computed tomography, the measurements showed the average error in localisation and alignment of the target was ±0.7mm. In terms of coordinate axis, the average error was: A-P axis = ±0.5mm, Lateral(left-right) Axis = ±0.3mm, Vertical(inferior superior) Axis ±0.4mm. From these measurements it was shown that using the stereotactic radiosurgery planning system and hardware, cranial lesions could be localised and

  15. Radiation tolerance of normal temporal bone structures: implications for gamma knife stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Linskey, Mark E.; Johnstone, Peter A.

    2003-01-01

    Popular current thought states that hearing loss and facial weakness after radiosurgery of vestibular schwannomas is a function of cranial nerve damage. Although this may be true in some cases, the middle and inner ear contain rich networks of other sensitive structures that are at risk after radiotherapy and that may contribute to toxicity afterward. We reviewed the limited reported data regarding radiation tolerance of external, middle, and inner ear structures, and perspectives for therapy with gamma knife stereotactic radiosurgery are addressed

  16. Stereotactic Radiosurgery versus Natural History in Patients with Growing Vestibular Schwannomas.

    Science.gov (United States)

    Tu, Albert; Gooderham, Peter; Mick, Paul; Westerberg, Brian; Toyota, Brian; Akagami, Ryojo

    2015-08-01

    Objective To describe our experience with stereotactic radiosurgery and its efficacy on growing tumors, and then to compare this result with the natural history of a similar cohort of non-radiation-treated lesions. Study Design A retrospective chart review and cohort comparison. Methods The long-term control rates of patients having undergone radiosurgery were collected and calculated, and this population was then compared with a group of untreated patients from the same period of time with growing lesions. Results A total of 61 patients with growing vestibular schwannomas treated with radiosurgery were included. After a mean of 160 months, we observed a control rate of 85.2%. When compared with a group of 36 patients with growing tumors who were yet to receive treatment (previously published), we found a corrected control rate or relative risk reduction of only 76.8%. Conclusion Radiosurgery for growing vestibular schwannomas is less effective than previously reported in unselected series. Although radiosurgery still has a role in managing this disease, consideration should be given to the actual efficacy that may be calculated when the natural history is known. We hope other centers will similarly report their experience on this cohort of patients.

  17. Stereotactic gamma radiosurgery of pineal and related tumors

    International Nuclear Information System (INIS)

    Kobayashi, Tatsuya; Mori, Yoshimasa; Yamada, Yasushi; Kida, Yoshihisa

    2001-01-01

    The role of gamma radiosurgery as an additional therapy after conventional treatments for pineal and related tumors was studied in 30 out of 33 cases with a mean follow-up of 23.3 months. Overall results showed that complete response (CR) was obtained in 8 cases (26.7%) and response rate was 73.3%. However, enlargement of the tumors was noted in 8 cases, of which 7 (23.3%) died of tumor progression (PG). Germinomas and pineocytomas showed higher response and control rates of 100%, and no tumor enlargement or death occurred after gamma knife treatment. In germinoma with STGC (syncytiotrophoblastic giant cell) which has been thought to have intermediate prognosis, two cases showed partial response (PR), but another died from progression of the disease. Malignant germ cell tumors and pineoblastomas showed unfavorable response and prognosis; the response and progression rates were 50%. However, complete response was obtained in 3 cases (25%) after gamma radiosurgery. Gamma knife was the initial treatment in three cases without pathological diagnosis in which one obtained CR and two showed partial response (PR). Stereotactic gamma radiosurgery is expected to be an effective and novel treatment for pineal and related tumors not only as an adjuvant, but also as an initial therapy. (author)

  18. Motion detection system with GPU acceleration for stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Yamakawa, Takuya; Ogawa, Koichi; Iyatomi, Hitoshi; Usui, Keisuke; Kunieda, Etsuo; Shigematsu, Naoyuki

    2012-01-01

    Stereotactic radiosurgery is a non-invasive method for the treatment of tumors that employs a narrow, high-energy X-ray beam. In this form of therapy, the target region is intensively irradiated with the narrow beam, and any unexpected patient motion may therefore lead to undesirable irradiation of neighboring normal tissues and organs. To overcome this problem, we propose a contactless motion detection system with three USB cameras for use in stereotactic radiosurgery of the head and neck. In our system, the three cameras monitor images of the patient's nose and ears, and patient motion is detected using a template-matching method. If patient motion is detected, the system alerts the radiologist to turn off the beam. We reduced the effects of variations in the lighting in the irradiation room by employing USB cameras sensitive to infrared light. To detect movement in the acquired images, we use a template-matching method that is realized with general-purpose computing-on-graphics processing units. In this paper, we present an outline of our proposed motion detection system based on monitoring of images of the patient acquired with infrared USB cameras and a template-matching method. The performance of the system was evaluated under the same conditions as those used in actual radiation therapy of the head and neck. (author)

  19. Linear accelerator based stereotactic radiosurgery with micro multi-leaf collimator : technological advancement in precision radiotherapy

    International Nuclear Information System (INIS)

    Dayananda, S.; Kinhikar, R.A.; Saju, Sherley; Deshpande, D.D.; Jalali, R.; Sarin, R.; Shrivastava, S.K.; Dinshaw, K.A.

    2003-01-01

    Stereotactic Radiosurgery (SRS) is an advancement on precision radiotherapy, in which stereo tactically guided localized high dose is delivered to the lesion (target) in a single fraction, while sparing the surrounding normal tissue. Radiosurgery has been used to treat variety of benign and malignant lesions as well as functional disorders in brain such as arteriovenous malformation (AVM), acoustic neuroma, solitary primary brain tumor, single metastasis, pituitary adenoma etc

  20. Enhanced intrinsic radiosensitivity after treatment with stereotactic radiosurgery for an acoustic neuroma

    International Nuclear Information System (INIS)

    Adams, Gerard; Martin, Olga A.; Roos, Daniel E.; Lobachevsky, Pavel N.; Potter, Andrew E.; Zacest, Andrew C.; Bezak, Eva; Bonner, William M.; Martin, Roger F.; Leong, Trevor

    2012-01-01

    Enhanced radiosensitivity is an uncommon phenomenon attributable to deficient DNA repair after radiotherapy which can be assessed with the γ-H2AX assay. Reports of radiosensitivity after stereotactic radiosurgery (SRS) are uncommon. We describe a case where the clinical, radiological and laboratory findings suggest enhanced radiosensitivity after SRS for an acoustic neuroma.

  1. The use of single fraction Leksell stereotactic radiosurgery in the treatment of uveal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Rennie, I. [Univ. of Sheffield, Dept. of Ophthalmology and Orthoptics (United Kingdom); Forster, D.; Kemeny, A. [Royal Hallamshire Hospital, Dept. of Neurosurgery (United Kingdom); Walton, L. [Royal Hallamshire Hospital, Dept. of Medical Physics (United Kingdom); Kunkler, I. [Weston Park Hospital, Dept. of Radiotherapy, Sheffield (United Kingdom)

    1996-11-01

    Fourteen patients with posterior uveal melanomas were treated using single fraction stereotactic radiosurgery. In each case a dose of 70 Gy was administered to the periphery of the tumour. Regression of the tumour has been observed in 13 patients, whilst the lesion has remained unchanged in one patient. The visual acuity has deteriorated in all 14 patients. Significant radiation induced adverse reactions were noted in 13 patients and include; retinopathy, optic neuropathy, rubeosis iridis, and secondary glaucoma. Two patients have required enucleation because of intractable rubeotic glaucoma. One patient has died from proven metastases. Although stereotactic radiosurgery appears to be a practical and effective method of treating uveal melanomas, its usefulness is limited by a high incidence of radiation induced adverse reactions. Further works is required to refine the current treatment protocol and establish an optimal prescription dose. (au) 30 refs.

  2. The use of single fraction Leksell stereotactic radiosurgery in the treatment of uveal melanoma

    International Nuclear Information System (INIS)

    Rennie, I.; Forster, D.; Kemeny, A.; Walton, L.; Kunkler, I.

    1996-01-01

    Fourteen patients with posterior uveal melanomas were treated using single fraction stereotactic radiosurgery. In each case a dose of 70 Gy was administered to the periphery of the tumour. Regression of the tumour has been observed in 13 patients, whilst the lesion has remained unchanged in one patient. The visual acuity has deteriorated in all 14 patients. Significant radiation induced adverse reactions were noted in 13 patients and include; retinopathy, optic neuropathy, rubeosis iridis, and secondary glaucoma. Two patients have required enucleation because of intractable rubeotic glaucoma. One patient has died from proven metastases. Although stereotactic radiosurgery appears to be a practical and effective method of treating uveal melanomas, its usefulness is limited by a high incidence of radiation induced adverse reactions. Further works is required to refine the current treatment protocol and establish an optimal prescription dose. (au) 30 refs

  3. The lazaroid U74389G protects normal brain from stereotactic radiosurgery-induced radiation injury

    International Nuclear Information System (INIS)

    Buatti, John M.; Friedman, William A.; Theele, Daniel P.; Bova, Francis J.; Mendenhall, William M.

    1996-01-01

    Purpose: To test an established model of stereotactic radiosurgery-induced radiation injury with pretreatments of either methylprednisolone or the lazaroid U74389G. Methods and Materials: Nine cats received stereotactic radiosurgery with a linear accelerator using an animal radiosurgery device. Each received a dose of 125.0 Gy prescribed to the 84% isodose shell to the anterior limb of the right internal capsule. One animal received no pretreatment, two received citrate vehicle, three received 30 mg/kg of methylprednisolone, and three received 5 mg/kg of U74389G. After irradiation, the animals had frequent neurologic examinations, and neurologic deficits developed in all of them. Six months after the radiation treatment, the animals were anesthetized, and had gadolinium-enhanced magnetic resonance (MR) scans, followed by Evans blue dye perfusion, euthanasia, and brain fixation. Results: Magnetic resonance scans revealed a decrease in the size of the lesions from a mean volume of 0.45 ± 0.06 cm 3 in the control, vehicle-treated, and methylprednisolone-treated animals to 0.22 ± 0.14 cm 3 in the U74389G-treated group. The scans also suggested the absence of necrosis and ventricular dilatation in the lazaroid-treated group. Gross pathology revealed that lesions produced in the untreated, vehicle-treated, and methylprednisolone-treated cats were similar and were characterized by a peripheral zone of Evans blue dye staining with a central zone of a mature coagulative necrosis and focal hemorrhage. However, in the U74389G-treated animals, the lesions were found to have an area of Evans blue dye staining, but lacked discrete areas of necrosis and hemorrhage. Conclusion: These results suggest that the lazaroid U74389G protects the normal brain from radiation injury produced by stereotactic radiosurgery

  4. Stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Souhami, L.; Podgorsak, E.B.

    1990-01-01

    Radiosurgery is an irradiation technique which over the last few years became frequently utilized. Because of the sophisticated and expensive equipments originally required, its use was restricted initially to a few and specialized centers in the world. The introduction of new techniques based on isocentric linear accelerators made now this therapy available to the major radiotherapy centers. Some of the essential requirements for radiosurgery include an accurate determination of the target volume, 3-dimensional dose calculation, accurate dose delivery to the target volume and a sharp dose fall-off outside the target volume. In this paper, we discuss the principles, the indications, some of the techniques, and the initial therapeutics results with radiosurgery. (author) [pt

  5. Stereotactic radiosurgery for acoustic neuroma: a Canadian perspective

    International Nuclear Information System (INIS)

    Ross, I.B.; Tator, C.H.

    1998-01-01

    Stereotactically delivered radiation is now an accepted treatment for patients with acoustic neuroma. In some cases, patient preference may be the reason for its selection, while in others neurosurgeons may select it for patients who are elderly or have significant risk factors for conventional surgery. The majority of patients with acoustic neuroma treatment with stereotactic radiosurgery have been treated with the Gamma Knife, with follow ups of over 25 years in some instances. Other radiosurgical modalities utilizing the linear accelerator have been developed and appear promising, but there is no long-term: follow up. Canada does not possess a Gamma Knife facility, and its government-funded hospital and medical insurance agencies have made it difficult for patients to obtain reimbursement for Gamma Knife treatments in other countries. We review the literature to date on the various forms of radiation treatment for acoustic neuroma and discuss the current issues facing physicians and patients in Canada who wish to obtain their treatment of choice. (author)

  6. Extracranial stereotactic radiotherapy: preliminary results with the CyberKnife.

    Science.gov (United States)

    Lartigau, Eric; Mirabel, Xavier; Prevost, Bernard; Lacornerie, Thomas; Dubus, Francois; Sarrazin, Thierry

    2009-04-01

    In the field of radiation oncology, equipment for fractionated radiotherapy and single-dose radiosurgery has become increasingly accurate, together with the introduction of robotized treatments. A robot is a device that can be programmed to carry out accurate, repeated and adjusted tasks in a given environment. Treatment of extracranial lesions involves taking into account organ mobility (tumor and healthy tissue) whilst retaining the ability to stereotactically locate the target. New imaging techniques (single-photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), positron emission tomography (PET)) provide further relevant information to slice images (computed tomography (CT) scans, MRI) for target definition. Hypo-fractionated treatments can only be used for curative treatment if the target is accurately defined and tracked during treatment. The CyberKnife is a non-invasive system of radiosurgery and fractionated stereotactic radiotherapy. For intracranial lesions treated by single-dose radiosurgery, it has been used to treat meningioma, acoustic neuromas, pituitary adenoma, metastases, arteriovenous malformations and refractory pain (trigeminal neuralgia). More than 10,000 patients have been treated worldwide. Currently, the most significant developments are in the field of extracranial stereotactic radiotherapy (lung, liver, reirradiation, prostate, etc.). Clinical results obtained in the CyberKnife Nord-Ouest program after 1 year of experience are presented. Copyright 2009 S. Karger AG, Basel.

  7. Stereotactic Radiosurgery for Benign (World Health Organization Grade I) Cavernous Sinus Meningiomas-International Stereotactic Radiosurgery Society (ISRS) Practice Guideline: A Systematic Review.

    Science.gov (United States)

    Lee, Cheng-Chia; Trifiletti, Daniel M; Sahgal, Arjun; DeSalles, Antonio; Fariselli, Laura; Hayashi, Motohiro; Levivier, Marc; Ma, Lijun; Álvarez, Roberto Martínez; Paddick, Ian; Regis, Jean; Ryu, Samuel; Slotman, Ben; Sheehan, Jason

    2018-03-15

    Stereotactic radiosurgery (SRS) has become popular as a standard treatment for cavernous sinus (CS) meningiomas. To summarize the published literature specific to the treatment of CS meningioma with SRS found through a systematic review, and to create recommendations on behalf of the International Stereotactic Radiosurgery Society. Articles published from January 1963 to December 2014 were systemically reviewed. Three electronic databases, PubMed, EMBASE, and The Cochrane Central Register of Controlled Trials, were searched. Publications in English with at least 10 patients (each arm) were included. Of 569 screened abstracts, a total of 49 full-text articles were included in the analysis. All studies were retrospective. Most of the reports had favorable outcomes with 5-yr progression-free survival (PFS) rates ranging from 86% to 99%, and 10-yr PFS rates ranging from 69% to 97%. The post-SRS neurological preservation rate ranged from 80% to 100%. Resection can be considered for the treatment of larger (>3 cm in diameter) and symptomatic CS meningioma in patients both receptive to and medically eligible for open surgery. Adjuvant or salvage SRS for residual or recurrent tumor can be utilized depending on factors such as tumor volume and proximity to adjacent critical organs at risk. The literature is limited to level III evidence with respect to outcomes of SRS in patients with CS meningioma. Based on the observed results, SRS offers a favorable benefit to risk profile for patients with CS meningioma.

  8. Imaging of arteriovenous malformation following stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Tranchida, J.V.; Mehall, C.J.; Slovis, T.L.; Lis-Planells, M.

    1997-01-01

    Background. Stereotactic radiosurgery allows for a high dose of focused radiation to be delivered to a small lesion such as an arteriovenous malformation (AVM). The clinical change and brain response over time to this localized high-dose radiation can be quite striking. Objective. The objective of this study to describe and analyse the imaging changes following radiotherapy for AVMs. Materials and methods. The clinical presentation and the imaging changes following radiotherapy in two patients were studied over the course of 1-2 years. Results. The imaging findings include diffuse low attenuation and contrast enhancement on CT. High-signal lesions were apparent on T2-weighted MR images with prominent contrast enhancement on T1-weighted images. Ring enhancement occurred over time. While new changes appeared over 12 months, these changes diminished during the second year. Conclusion. Radiotherapy induces inflammatory changes that are generally reversible but can lead to parenchymal destruction. These imaging changes are often nonspecific and therefore must be interpreted in light of clinical symptomatology and the time course since treatment. These patients should receive routine MR imaging within 3 months after radiosurgery with follow-up imaging at 6, 12, and 18 months. (orig.). With 8 figs

  9. Stereotactic radiosurgery for the treatment of mesial temporal lobe epilepsy.

    Science.gov (United States)

    Feng, E-S; Sui, C-B; Wang, T-X; Sun, G-L

    2016-12-01

    Stereotactic radiosurgery (RS) is a potential option for some patients with temporal lobe epilepsy (TLE). The aim of this meta-analysis was to determine the pooled seizure-free rate and the time interval to seizure cessation in patients with lesions in the mesial temporal lobe, and who were eligible for either stereotactic or gamma knife RS. We searched the Medline, Cochrane, EMBASE, and Google Scholar databases using combinations of the following terms: RS, stereotactic radiosurgery, gamma knife, and TLE. We screened 103 articles and selected 13 for inclusion in the meta-analysis. Significant study heterogeneity was detected; however, the included studies displayed an acceptable level of quality. We show that approximately half of the patients were seizure free over a follow-up period that ranged from 6 months to 9 years [pooled estimate: 50.9% (95% confidence interval: 0.381-0.636)], with an average of 14 months to seizure cessation [pooled estimate: 14.08 months (95% confidence interval: 11.95-12.22 months)]. Nine of 13 included studies reported data for adverse events (AEs), which included visual field deficits and headache (the two most common AEs), verbal memory impairment, psychosis, psychogenic non-epileptic seizures, and dysphasia. Patients in the individual studies experienced AEs at rates that ranged from 8%, for non-epileptic seizures, to 85%, for headache. Our findings indicate that RS may have similar or slightly less efficacy in some patients compared with invasive surgery. Randomized controlled trials of both treatment regimens should be undertaken to generate an evidence base for patient decision-making. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Early experiences of planning stereotactic radiosurgery using 3D printed models of eyes with uveal melanomas

    Directory of Open Access Journals (Sweden)

    Furdová A

    2017-01-01

    Full Text Available Alena Furdová,1 Miron Sramka,2 Andrej Thurzo,3 Adriana Furdová3 1Department of Ophthalmology, Faculty of Medicine, Comenius University, 2Department of Stereotactic Radiosurgery, St Elisabeth Cancer Inst and St Elisabeth University College of Health and Social Work, 3Department of Simulation and Virtual Medical Education, Faculty of Medicine, Comenius University, Bratislava, Slovak Republic Objective: The objective of this study was to determine the use of 3D printed model of an eye with intraocular tumor for linear accelerator-based stereotactic radiosurgery.Methods: The software for segmentation (3D Slicer created virtual 3D model of eye globe with tumorous mass based on tissue density from computed tomography and magnetic resonance imaging data. A virtual model was then processed in the slicing software (Simplify3D® and printed on 3D printer using fused deposition modeling technology. The material that was used for printing was polylactic acid.Results: In 2015, stereotactic planning scheme was optimized with the help of 3D printed model of the patient’s eye with intraocular tumor. In the period 2001–2015, a group of 150 patients with uveal melanoma (139 choroidal melanoma and 11 ciliary body melanoma were treated. The median tumor volume was 0.5 cm3 (0.2–1.6 cm3. The radiation dose was 35.0 Gy by 99% of dose volume histogram.Conclusion: The 3D printed model of eye with tumor was helpful in planning the process to achieve the optimal scheme for irradiation which requires high accuracy of defining the targeted tumor mass and critical structures. Keywords: 3D printing, uveal melanoma, stereotactic radiosurgery, linear accelerator, intraocular tumor, stereotactic planning scheme

  11. Initial clinical experience with frameless radiosurgery for patients with intracranial metastases

    International Nuclear Information System (INIS)

    Kamath, Reena; Ryken, Timothy C.; Meeks, Sanford L.; Pennington, Edward C.; Ritchie, Justine; Buatti, John M.

    2005-01-01

    Purpose: To review the initial clinical experience with frameless stereotactic radiosurgery (SRS) for treating intracranial metastatic disease. Methods and Materials: Sixty-four patients received frameless SRS for intracranial metastatic disease. Minimum follow-up was 6 months with none lost to follow-up. Patients had a median of 2 metastases and a maximum of 4. The median number of isocenters was 2 with median arcs of 10 and median dose of 17.5 Gy. Thirteen patients were treated for progressive/recurrent disease after surgical resection or whole brain radiotherapy (WBRT). Fifty-one patients were treated with frameless SRS as an an adjunct to initial treatment. Of the total treated, 17 were treated with SRS alone, 20 were treated with WBRT plus SRS, 16 were treated with surgical resection plus SRS, and the remaining 11 were treated with surgical resection plus WBRT plus SRS. Results: With a median actuarial follow-up period of 8.2 months, ultimate local control was 88%. The median time to progression was 8.1 months. The median overall survival was 8.7 months. Of the 17 patients treated with SRS alone, 86% had ultimate local control with mean overall survival of 7.1 months. Of the 13 patients who received surgical resection plus SRS without WBRT as primary treatment, there was 85% ultimate local control with an overall survival of 10.3 months. Three patients treated with initial surgery alone had recurrence treated with SRS 2-3 months after resection. All these patients obtained local control and median survival was >10 months. Of the 13 patients who received WBRT followed by SRS as boost treatment, 92% had local control and mean overall survival was 7.3 months. Of 7 patients who received SRS after recurrence after WBRT, 100% had local control with median survival of 8.2 months. For 8 patients who received surgery followed by WBRT and SRS, local control was 50%; however, ultimate intracranial control was achieved in 7 of 8 patients with repeat SRS and surgical

  12. Conformity of LINAC-Based Stereotactic Radiosurgery Using Dynamic Conformal Arcs and Micro-Multileaf Collimator

    International Nuclear Information System (INIS)

    Hazard, Lisa J.; Wang, Brian; Skidmore, Thomas B.; Chern, Shyh-Shi; Salter, Bill J.; Jensen, Randy L.; Shrieve, Dennis C.

    2009-01-01

    Purpose: To assess the conformity of dynamic conformal arc linear accelerator-based stereotactic radiosurgery and to describe a standardized method of isodose surface (IDS) selection. Methods and Materials: In 174 targets, the conformity index (CI) at the prescription IDS used for treatment was calculated as CI = (PIV/PVTV)/(PVTV/TV), where TV is the target volume, PIV (prescription isodose volume) is the total volume encompassed by the prescription IDS, and PVTV is the TV encompassed by the IDS. In addition, a 'standardized' prescription IDS (sIDS) was chosen according to the following criteria: 95% of the TV was encompassed by the PIV and 99% of TV was covered by 95% of the prescription dose. The CIs at the sIDS were also calculated. Results: The median CI at the prescription IDS and sIDS was 1.63 and 1.47, respectively (p < 0.001). In 132 of 174 cases, the volume of normal tissue in the PIV was reduced by the prescription to the sIDS compared with the prescription IDS, in 20 cases it remained unchanged, and in 22 cases it was increased. Conclusion: The CIs obtained with linear accelerator-based stereotactic radiosurgery are comparable to those previously reported for gamma knife stereotactic radiosurgery. Using a uniform method to select the sIDS, adequate target coverage was usually achievable with prescription to an IDS greater than that chosen by the treating physician (prescription IDS), providing sparing of normal tissue. Thus, the sIDS might aid physicians in identifying a prescription IDS that balances coverage and conformity

  13. Long-Term Results of Gamma Knife Radiosurgery for Intracranial Meningioma.

    Science.gov (United States)

    Jang, Chang Ki; Jung, Hyun Ho; Chang, Jong Hee; Chang, Jin Woo; Park, Yong Gou; Chang, Won Seok

    2015-10-01

    The predominant treatment modality for meningioma is surgical resection. However, gamma knife radiosurgery is also an important treatment modality for meningioma that is small or cannot be completely removed because of its location. In this study, we evaluated the effectiveness and long-term results of radiosurgical treatment for meningioma in our institution. We studied 628 patients (130 men and 498 women) who underwent gamma knife radiosurgery for intracranial meningioma, which is radiologically diagnosed, from Jan 2008 to Nov 2012. We included patients with single lesion meningioma, and followed up after 6 months with imaging, and then at 24 months with a clinical examination. Patients with high-grade meningioma or multiple meningiomas were excluded. We analyzed each of the factors associated with progression free survival. The median patient's age was 56.8 years. Maximal dosage was 27.8 Gy and marginal dosage was 13.9 Gy. The overall tumor control rate was 95%. Twenty-eight patients (4.4%) showed evidence of tumor recurrence. Ninety-eight patients (15%) developed peritumoral edema (PTE) after gamma-knife surgery; two of them (2%) underwent surgical resections due to PTE. Nine patients had craniotomy and tumor removal after gamma knife surgery. Gamma knife surgery for intracranial meningioma has proven to be a safe and effective treatment tool with successful long-term outcomes. Gamma knife radiosurgery can be especially effective in cases of remnant meningioma after surgical resection or where PTE is not present.

  14. The role of stereotactic radiosurgery in the treatment of malignant skull base tumors

    International Nuclear Information System (INIS)

    Miller, Robert C.; Foote, Robert L.; Coffey, Robert J.; Gorman, Deborah A.; Earle, John D.; Schomberg, Paula J.; Kline, Robert W.

    1997-01-01

    Purpose: To determine the efficacy and toxicity of stereotactic radiosurgery in the treatment of malignant skull base tumors. Methods and Materials: Thirty-two patients with 35 newly diagnosed or recurrent malignant skull base tumors ≤33.5 cm 3 were treated using the Leksell Gamma unit. Tumor histologies included: adenoid cystic carcinoma, basal cell carcinoma, chondrosarcoma, chordoma, nasopharyngeal carcinoma, osteogenic sarcoma, and squamous cell carcinoma. Results: After a median follow-up of 2.3 years, 83% ± 15% (±95% confidence interval) of patients experienced a symptomatic response to treatment. Local control at the skull base was 95 ± 9% at 2 years and 78 ± 23% at 3 years. Local-regional control above the clavicles was 75 ± 15% at 1 year and 51 ± 20% at 2 years. Overall and cause specific survival were identical, 82 ± 13% at 1 year, 76 ± 14% at 2 years, and 72 ± 16% at 3 years. One patient developed a radiation-induced optic neuropathy 12 months after radiosurgery. Conclusion: Stereotactic radiosurgery using the Leksell Gamma Unit can provide durable tumor control and symptomatic relief with acceptable toxicity in the majority of patients with malignant tumors 4 cm or less in size involving the skull base. Further evaluation of more patients with longer follow-up is warranted

  15. Single-fraction vs. fractionated linac-based stereotactic radiosurgery for vestibular schwannoma: a single-institution study

    NARCIS (Netherlands)

    Meijer, O. W. M.; Vandertop, W. P.; Baayen, J. C.; Slotman, B. J.

    2003-01-01

    PURPOSE: In this single-institution trial, we investigated whether fractionated stereotactic radiation therapy is superior to single-fraction linac-based radiosurgery with respect to treatment-related toxicity and local control in patients with vestibular schwannoma. METHODS AND MATERIALS: All 129

  16. Clinical experience of stereotactic radiosurgery at a linear accelerator for intraocular melanoma.

    Science.gov (United States)

    Furdova, Alena; Sramka, Miron; Chorvath, Martin; Kralik, Gabriel; Furda, Robert; Gregus, Michal

    2017-10-01

    Long-term results with linear accelerator LINAC-based stereotactic radiosurgery for intraocular uveal malignant melanoma were assessed. A retrospective study was carried out of patients with uveal melanoma after a 1-day session stereotactic radiosurgery at LINAC in Slovakia. In the period 2001-2015, a group of 150 patients with uveal melanoma (139 choroidal melanoma, 11 ciliary body melanoma) was treated. The median tumor volume at baseline was 0.5 cm (with range from 0.2 to 1.6 cm). Tumors ranged in size from 2.4 to 20.8 mm in basal diameter and from 2.0 to 18.3 mm in thickness. The therapeutic dose was 35.0 Gy by 99% of dose volume histogram. Older age at treatment was correlated with the largest basal tumor diameter, tumor thickness, and TNM stage. The survival after stereotactic irradiation was 96% in 1 year, 93% in 2 years, 84% in 5 years, 80% in 7 years, and 53% in 11 years. In 20 (13.3%) patients, secondary enucleation was necessary because of complications (secondary glaucoma). Enucleation-free interval ranged from 1 to 6 years. The median age at death was lower (65.7 years) for patients who died from metastatic disease than for those who died from any other cause (75.0 years). Survival rates at 5-year intervals and the need for secondary enucleation because of complications after linear accelerator irradiation are comparable to other techniques.

  17. Technical Note: Dose gradients and prescription isodose in orthovoltage stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Fagerstrom, Jessica M.; Bender, Edward T.; Culberson, Wesley S.

    2016-01-01

    Purpose: The purpose of this work is to examine the trade-off between prescription isodose and dose gradients in orthovoltage stereotactic radiosurgery. Methods: Point energy deposition kernels (EDKs) describing photon and electron transport were calculated using Monte Carlo methods. EDKs were generated from 10  to 250 keV, in 10 keV increments. The EDKs were converted to pencil beam kernels and used to calculate dose profiles through isocenter from a 4π isotropic delivery from all angles of circularly collimated beams. Monoenergetic beams and an orthovoltage polyenergetic spectrum were analyzed. The dose gradient index (DGI) is the ratio of the 50% prescription isodose volume to the 100% prescription isodose volume and represents a metric by which dose gradients in stereotactic radiosurgery (SRS) may be evaluated. Results: Using the 4π dose profiles calculated using pencil beam kernels, the relationship between DGI and prescription isodose was examined for circular cones ranging from 4 to 18 mm in diameter and monoenergetic photon beams with energies ranging from 20 to 250 keV. Values were found to exist for prescription isodose that optimize DGI. Conclusions: The relationship between DGI and prescription isodose was found to be dependent on both field size and energy. Examining this trade-off is an important consideration for designing optimal SRS systems.

  18. Monteris AXiiiS Stereotactic Miniframe for Intracranial Biopsy: Precision, Feasibility, and Ease of Use.

    Science.gov (United States)

    Manjila, Sunil; Knudson, Kathleen E; Johnson, Carleton; Sloan, Andrew E

    2016-06-01

    Stereotactic biopsy is an important and minimally invasive technique used for a variety of indications in neurosurgery. Initially, this technique required a frame, but recently there have been a number of newer, less cumbersome approaches to biopsy including robotic arms, fixed arms, and, more recently, skull-mounted miniframes. Miniframes are attractive because they are disposable and low profile. However, the relatively limited degree of freedom offered by currently available devices necessitates a preplanned burr hole, which in turn limits flexibility and multiple trajectories. The AXiiiS device is a skull-mounted, magnetic resonance imaging-compatible miniframe that provides a similar degree of freedom with a frame while maintaining a low-profile, disposable platform. To assess the image-guided trajectory alignment accuracy using AXiiiS stereotactic miniframe biopsy of intracranial lesions. The accuracy of the AXiiiS device is compared with the Navigus Trajectory Guide as platforms. After approval by our institutional review board, medical records of 10 neurosurgical patients with intracranial pathologies were chosen for AXiiiS stereotactic miniframe biopsy, and histological correlation was obtained. Ten reported cases demonstrate the precision and ease of using the AXiiiS stereotactic miniframe for biopsy of intracranial lesions in conjunction with preoperative magnetic resonance imaging. Multiple trajectories and angles have been used with precision and safety. The AXiiiS stereotactic miniframe is a feasible, safe, and disposable platform for multitrajectory intracranial biopsies. Compared with existing platforms, this novel device provides a more stable base and wider limits of trajectory angles with comparable accuracy and precision.

  19. Treatment of arteriovenous malformations with stereotactic radiosurgery employing both magnetic resonance angiography and standard angiography as a database

    International Nuclear Information System (INIS)

    Petereit, D.; Mehta, M.; Turski, P.; Levin, A.; Strother, C.; Mistretta, C.; Mackie, R.; Gehring, M.; Kubsad, S.; Kinsella, T.

    1993-01-01

    Twenty-one arteriovenous malformations were prospectively evaluated using magnetic resonance angiography, compare it to stereotactic angiography, employ magnetic resonance angiography in follow-up, and semiquanitfy flow. A correlative evaluation between flow and response to stereotactic radiosurgery was carried out. Phase contrast angiograms were obtained at flow velocities of 400, 200, 100, 60 and 20 cm/sec. The fractionated velocities provided images that selectively demonstrated the arterial and venous components of the arteriovenous malformations. Qualitative assessment of the velocity within the arteriovenous malformations and the presence of fistulae were also determined by multiple velocity images. In addition, 3-dimensional time-of-flight magnetic resonance angiograms were obtained to define the exact size and shape of the nidus. This technique also permitted evaluation of the nidus and feeding arteries for the the presence of low flow aneurysms. Correlation between the two imaging modalities was carried out by subjective and semiquantitative estimation of flow velocity and estimation of nidus size. The following velocity parameters were employed: fast, intermediate, slow, and none. Early analysis suggests that slower flowing arteriovenous malformations may obliterate faster after stereotactic radiosurgery an flow parameters should be employed to predict response. In conclusion, magnetic resonance angiography permits semiquantitative flow velocity assessment and may therefore be superior to stereotactic angiography. An additional advantage of magnetic resonance angiography is the generation of serial transverse images which can replace the conventional CT scan employed for stereotactic radiosurgery treatment planning. A single diagnostic test may therefore be used for diagnosis, radiosurgical treatment planning, follow-up, and treatment selection by identifying patients likely to respond early to radiosurgical management

  20. TH-A-BRC-02: AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Goetsch, S. [San Diego Medical Physics (United States)

    2016-06-15

    AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline

  1. TH-A-BRC-02: AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance

    International Nuclear Information System (INIS)

    Goetsch, S.

    2016-01-01

    AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline

  2. ASSOCIATION BETWEEN COMPUTED TOMOGRAPHIC CHARACTERISTICS AND FRACTURES FOLLOWING STEREOTACTIC RADIOSURGERY IN DOGS WITH APPENDICULAR OSTEOSARCOMA.

    Science.gov (United States)

    Kubicek, Lyndsay; Vanderhart, Daniel; Wirth, Kimberly; An, Qi; Chang, Myron; Farese, James; Bova, Francis; Sudhyadhom, Atchar; Kow, Kelvin; Bacon, Nicholas J; Milner, Rowan

    2016-05-01

    The objective of this observational, descriptive, retrospective study was to report CT characteristics associated with fractures following stereotactic radiosurgery in canine patients with appendicular osteosarcoma. Medical records (1999 and 2012) of dogs that had a diagnosis of appendicular osteosarcoma and undergone stereotactic radiosurgery were reviewed. Dogs were included in the study if they had undergone stereotactic radiosurgery for an aggressive bone lesion with follow-up information regarding fracture status, toxicity, and date and cause of death. Computed tomography details, staging, chemotherapy, toxicity, fracture status and survival data were recorded. Overall median survival time (MST) and fracture rates of treated dogs were calculated. CT characteristics were evaluated for association with time to fracture. Forty-six dogs met inclusion criteria. The median overall survival time was 9.7 months (95% CI: 6.9-14.3 months). The fracture-free rates at 3, 6, and 9 months were 73%, 44%, and 38% (95% CI: 60-86%, 29-60%, and 22-54%), respectively. The region of bone affected was significantly associated with time to fracture. The median time to fracture was 4.2 months in dogs with subchondral bone involvement and 16.3 months in dogs without subchondral bone involvement (P-value = 0.027, log-rank test). Acute and late skin effects were present in 58% and 16% of patients, respectively. Findings demonstrated a need for improved patient selection for this procedure, which can be aided by CT-based prognostic factors to predict the likelihood of fracture. © 2016 American College of Veterinary Radiology.

  3. Stereotactic radiosurgery vs. fractionated radiotherapy for tumor control in vestibular schwannoma patients

    DEFF Research Database (Denmark)

    Persson, Oscar; Bartek, Jiri; Shalom, Netanel Ben

    2017-01-01

    OBJECTIVE: Repeated controlled studies have revealed that stereotactic radiosurgery is better than microsurgery for patients with vestibular schwannoma (VS) ... to patients treated with fractionated stereotactic radiotherapy. RESULTS: No randomized controlled trial (RCT) was identified. None of the identified controlled studies comparing SRS with FSRT were eligible according to the inclusion criteria. Nineteen case series on SRS (n = 17) and FSRT (n = 2) were...... included in the systematic review. Loss of tumor control necessitating a new VS-targeted intervention was found in an average of 5.0% of the patients treated with SRS and in 4.8% treated with FSRT. Mean deterioration ratio for patients with serviceable hearing before treatment was 49% for SRS and 45...

  4. Adverse radiation effect after stereotactic radiosurgery for brain metastases : incidence, time course, and risk factors

    NARCIS (Netherlands)

    Sneed, Penny K.; Mendez, Joe; Vemer-van den Hoek, Johanna; Seymour, Zachary A.; Ma, Lijun; Molinaro, Annette M.; Fogh, Shannon E.; Nakamura, Jean L.; McDermott, Michael W.

    OBJECT The authors sought to determine the incidence, time course, and risk factors for overall adverse radiation effect (ARE) and symptomatic ARE after stereotactic radiosurgery (SRS) for brain metastases. METHODS All cases of brain metastases treated from 1998 through 2009 with Gamma Knife SRS at

  5. Repeat Stereotactic Radiosurgery for Acoustic Neuromas

    International Nuclear Information System (INIS)

    Kano, Hideyuki; Kondziolka, Douglas; Niranjan, Ajay M.Ch.; Flannery, Thomas J.; Flickinger, John C.; Lunsford, L. Dade

    2010-01-01

    Purpose: To evaluate the outcome of repeat stereotactic radiosurgery (SRS) for acoustic neuromas, we assessed tumor control, clinical outcomes, and the risk of adverse radiation effects in patients whose tumors progressed after initial management. Methods and Materials: During a 21-year experience at our center, 1,352 patients underwent SRS as management for their acoustic neuromas. We retrospectively identified 6 patients who underwent SRS twice for the same tumor. The median patient age was 47 years (range, 35-71 years). All patients had imaging evidence of tumor progression despite initial SRS. One patient also had incomplete surgical resection after initial SRS. All patients were deaf at the time of the second SRS. The median radiosurgery target volume at the time of the initial SRS was 0.5 cc and was 2.1 cc at the time of the second SRS. The median margin dose at the time of the initial SRS was 13 Gy and was 11 Gy at the time of the second SRS. The median interval between initial SRS and repeat SRS was 63 months (range, 25-169 months). Results: At a median follow-up of 29 months after the second SRS (range, 13-71 months), tumor control or regression was achieved in all 6 patients. No patient developed symptomatic adverse radiation effects or new neurological symptoms after the second SRS. Conclusions: With this limited experience, we found that repeat SRS for a persistently enlarging acoustic neuroma can be performed safely and effectively.

  6. The safety and efficacy of robotic image-guided radiosurgery system treatment for intra- and extracranial lesions: A systematic review of the literature

    International Nuclear Information System (INIS)

    Calcerrada Diaz-Santos, Nieves; Blasco Amaro, Juan Antonio; Cardiel, Gloria Ariza; Andradas Aragones, Elena

    2008-01-01

    Background: The CyberKnife is a new, frameless stereotactic radiosurgery system. This work reviews its safety and efficacy in the treatment of intra- and extracranial lesions. Methods: A literature search was made of the Medline, Embase, Pascal Biomed, CINAHL and Cancerlit databases. Health technology assessment reports on stereotactic radiosurgery systems were also consulted. All searches were made in June 2007. Data on efficacy and safety were extracted and then synthesized into the present review. Results: Thirty five clinical studies were identified, the majority of which included no patient comparison group. These studies assessed the use of the CyberKnife mainly in the treatment of primary and metastatic intracranial and spinal tumours. Conclusions: The CyberKnife system allows to carry out standard radiosurgical and fractionated stereotactic radiotherapy procedures. The use of this system offers an alternative for the treatment of inoperable tumours, and of lesions located close to critical structures that cannot be treated using other types of stereotactic radiosurgery system. Unfortunately, the quality of the reviewed papers still does not allow definite conclusions to be drawn regarding the safety and efficacy of these treatments

  7. A modification to the Gill-Thomas-Cosman (GTC) head frame for stereotactic radiosurgery of head and neck and cervical spine sites

    International Nuclear Information System (INIS)

    Qian, G.; Hasala, P.; Rashid, H.; Costantino, T.; Cangiane, L.; Lombardi, E.; Arbit, E; Lederman, G.

    1996-01-01

    PURPOSE/OBJECTIVE: Fractionated Stereotactic Radiosurgery (FSR) is used primarily to treat intracranial lesions. Many tumors which arise at or inferior to the base of skull and about the cervical spine area were not amenable to radiosurgery. Presented is a modification to the GTC head frame which permits stereotactic radiosurgery to be directed at head and neck tumors with accurate reproducible precision. MATERIALS AND METHODS: The original GTC head frame has two fixation points; an anterior individualized dental impression and a posterior occipital plate with a mold contoured to the occipital pertuberance. The height of the occipital plate is adjustable in its vertical plane. However, the position of the dental piece is fixed and, therefore, limits treatment to regions superior. Treatment of head and neck and cervical spine tumors has been accomplished with a modification of the dental apparatus. Presented is our new device; a bracket extension which attaches to the dental piece and allows the head frame to be lowered to multiple desired positions. The occipital plate is elevated accordingly to support the occipital pertuberance. The depth helmet is also modified for quality assurance. A Rando phantom was used to test the accuracy and reproducibility of the new equipment. Bracket extensions lowering the head frame by 3 cm and 8 cm, respectively, were tested for accuracy of relocation on the Rando Phantom. Each extension was tested 20 times and for each individual test 18 depth helmet positions were obtained. RESULTS: The standard deviation of the modified head frame for each depth helmet measurement ranged from 0.05 to 0.35mm (mean 0.20) as compared to the standard deviation for the original GTC head frame which was 0.13 to 0.34mm (mean 0.24). The new device maintains the accuracy and reproducibility of the original GTC head frame. CONCLUSION: The GTC relocatable head frame for FSR has been modified to treat tumors of the head and neck and cervical spine sites

  8. Neurosymptomatic carvenous sinus meningioma: a 15-years experience with fractionated stereotactic radiotherapy and radiosurgery

    International Nuclear Information System (INIS)

    Correa, Sebastião Francisco Miranda; Marta, Gustavo Nader; Teixeira, Manoel Jacobsen

    2014-01-01

    The tumor removal of Cavernous Sinus Meningiomas usually results in severe neurological deficits. Stereotactic radiosurgery (SRS) and fractionated Stereotactic radiotherapy (SRT) are advanced modalities of radiotherapy for treatment of patients with inoperable and symptomatic CSMs. The authors evaluated the long term symptomatology, the image findings, and the toxicity of patients with CSMs treated with SRS or SRT. From 1994 to 2009, 89 patients with symptomatic CSMs were treated with SRS or SRT. The indication was based on tumour volume and or proximity to the optic chiasm. The median single dose of SRS was 14 Gy, while the SRT total dose, ranged from 50.4 to 54 Gy fractionated in 1.8-2 Gy/dose. The median follow-up period lasted 73 months. The clinical and radiological improvement was the same despite the method of radiotherapy; 41.6% (SRS) and 48.3% (SRT) of patients treated. The disease-free survivals were 98.8%, 92.3% and 92.3%, in 5, 10, and 15 years, respectively. There was no statistical difference in relation to the symptoms and image findings between both methods. According to the Common Toxicity Criteria, 7% of the patients presented transient optic neuropathy during 3 months (grade 2) and recovered with dexamethasone, 2 patients had trigeminal neuropathy (grade 2) and improved rapidly, and one patient presented total occlusion of the internal carotid artery without neurological deficit (grade 2). Temporary lethargy and headache (grade 1) were the most frequent immediate complications. No severe complications occurred. Stereotactic Radiosurgery and fractionated Stereotactic Radiotherapy were equally safe and effective in the management of symptomatic CSMs

  9. CyberKnife radiosurgery: Precision without incision

    Directory of Open Access Journals (Sweden)

    Enja Siva Prasad Reddy

    2015-01-01

    Full Text Available CyberKnife stereotactic radiosurgery system is an innovative, effective, frameless, non-invasive substitute for conventional surgical treatment of cancer. It works on the principle of stereotaxy. It is used for the treatment of both cancerous and non-cancerous tumors, intracranial lesions, tumors of lung, spine, prostate, and kidney, recurrent cases of oral squamous cell carcinoma, arteriovenous malformation, and trigeminal neuralgia. It has an advantage over other systems like Gamma knife radiosurgery and linear accelerator (LINAC-based systems, as it is frameless, has submillimeter accuracy, does not affect the normal cells adjacent to the lesion, and tracks the lesion in synchronization with the patient′s respiratory rate. The future of CyberKnife encompasses possibilities such as incremental improvements in accuracy and better shaping of the field of radiation and would certainly allow extension of radiosurgery as an effective substitute for chemotherapy. This paper aims to review and highlight the immense potential that CyberKnife holds in the field of dentistry in treating disorders of the head and neck region, thereby ensuring enhanced longevity for the patients.

  10. A treatment planning comparison between a novel rotating gamma system and robotic linear accelerator based intracranial stereotactic radiosurgery/radiotherapy

    Science.gov (United States)

    Fareed, Muhammad M.; Eldib, Ahmed; Weiss, Stephanie E.; Hayes, Shelly B.; Li, Jinsheng; C-M Ma, Charlie

    2018-02-01

    To compare the dosimetric parameters of a novel rotating gamma ray system (RGS) with well-established CyberKnife system (CK) for treating malignant brain lesions. RGS has a treatment head of 16 cobalt-60 sources focused to the isocenter, which can rotate 360° on the ring gantry and swing 35° in the superior direction. We compared several dosimetric parameters in 10 patients undergoing brain stereotactic radiosurgery including plan normalization, number of beams and nodes for CK and shots for RGS, collimators used, estimated treatment time, D 2 cm and conformity index (CI) among two modalities. The median plan normalization for RGS was 56.7% versus 68.5% (p  =  0.002) for CK plans. The median number of shots from RGS was 7.5 whereas the median number of beams and nodes for CK was 79.5 and 46. The median collimator’s diameter used was 3.5 mm for RGS as compared to 5 mm for CK (p  =  0.26). Mean D 2 cm was 5.57 Gy for CyberKnife whereas it was 3.11 Gy for RGS (p  =  0.99). For RGS plans, the median CI was 1.4 compared to 1.3 for the CK treatment plans (p  =  0.98). The average minimum and maximum doses to optic chiasm were 21 and 93 cGy for RGS as compared to 32 and 209 cGy for CK whereas these were 0.5 and 364 cGy by RGS and 18 and 399 cGy by CK to brainstem. The mean V12 Gy for brain predicting for radionecrosis with RGS was 3.75 cm3 as compared to 4.09 cm3 with the CK (p  =  0.41). The dosimetric parameters of a novel RGS with a ring type gantry are comparable with CyberKnife, allowing its use for intracranial lesions and is worth exploring in a clinical setting.

  11. Results of stereotactic radiosurgery for patients with imaging defined cavernous sinus meningiomas

    International Nuclear Information System (INIS)

    Pollock, Bruce E.; Stafford, Scott L.

    2005-01-01

    Introduction: The purpose of this study was to evaluate the efficacy and safety of stereotactic radiosurgery as primary management for patients with imaging defined cavernous sinus meningiomas. Methods: Between 1992 and 2001, 49 patients had radiosurgery for dural-based masses of the cavernous sinus presumed to be meningiomas. The mean patient age was 55.5 years. The mean tumor volume was 10.2 mL; the mean tumor margin dose was 15.9 Gy. The mean follow-up was 58 months (range, 16-144 months). Results: No tumor enlarged after radiosurgery. Twelve of 38 patients (26%) with preexisting diplopia or facial numbness/pain had improvement in cranial nerve function. Five patients (10%) had new (n = 3) or worsened (n = 2) trigeminal dysfunction; 2 of these patients (4%) underwent surgery at 20 and 25 months after radiosurgery despite no evidence of tumor progression. Neither patient improved after partial tumor resection. One patient (2%) developed an oculomotor nerve injury. One patient (2%) had an ischemic stroke related to occlusion of the cavernous segment of the internal carotid artery. Event-free survival was 98%, 85%, and 80% at 1, 3, and 7 years after radiosurgery, respectively. Univariate analysis of patient and dosimetric factors found no analyzed factor correlated with postradiosurgical morbidity. Conclusions: Radiosurgery was an effective primary management strategy for patients with an imaging defined cavernous sinus meningioma. Except in situations of symptomatic mass effect, unusual clinical presentation, or atypical imaging features, surgery to confirm the histologic diagnosis is unlikely to provide clinical benefit

  12. Clinical Evaluation of Stereotactic Target Localization Using 3-Tesla MRI for Radiosurgery Planning

    International Nuclear Information System (INIS)

    MacFadden, Derek; Zhang Beibei; Brock, Kristy K.; Hodaie, Mojgan; Laperriere, Normand; Schwartz, Michael; Tsao, May; Stainsby, Jeffrey; Lockwood, Gina; Mikulis, David; Menard, Cynthia

    2010-01-01

    Purpose: Increasing the magnetic resonance imaging (MRI) field strength can improve image resolution and quality, but concerns remain regarding the influence on geometric fidelity. The objectives of the present study were to spatially investigate the effect of 3-Tesla (3T) MRI on clinical target localization for stereotactic radiosurgery. Methods and Materials: A total of 39 patients were enrolled in a research ethics board-approved prospective clinical trial. Imaging (1.5T and 3T MRI and computed tomography) was performed after stereotactic frame placement. Stereotactic target localization at 1.5T vs. 3T was retrospectively analyzed in a representative cohort of patients with tumor (n = 4) and functional (n = 5) radiosurgical targets. The spatial congruency of the tumor gross target volumes was determined by the mean discrepancy between the average gross target volume surfaces at 1.5T and 3T. Reproducibility was assessed by the displacement from an averaged surface and volume congruency. Spatial congruency and the reproducibility of functional radiosurgical targets was determined by comparing the mean and standard deviation of the isocenter coordinates. Results: Overall, the mean absolute discrepancy across all patients was 0.67 mm (95% confidence interval, 0.51-0.83), significantly .4), and the gross target volume surface mean displacements were similar within and between users. The overall average isocenter coordinate discrepancy for the functional targets at 1.5T and 3T was 0.33 mm (95% confidence interval, 0.20-0.48), with no patient-specific differences between the mean values (p >.2) or standard deviations (p >.1). Conclusion: Our results have provided clinically relevant evidence supporting the spatial validity of 3T MRI for use in stereotactic radiosurgery under the imaging conditions used.

  13. Technical and anatomical aspects of novalis stereotactic radiosurgery sphenopalatine ganglionectomy

    International Nuclear Information System (INIS)

    De Salles, Antonio A.F.; Gorgulho, Alessandra; Golish, S. Raymond Ph.D.; Medin, Paul M.; Malkasian, Dennis; Solberg, Timothy D.; Selch, Michael T.

    2006-01-01

    Background: Several techniques have been applied for destruction of the sphenopalatine ganglion to control cluster headache and ocular pain with sympathetic component. Cluster headache has responded to radiofrequency ablation or phenol destruction. Radiosurgery of the sphenopalatine ganglion is promising due to the excellent visualization of the target on magnetic resonance imaging (MRI), computed tomography (CT), and skull X-rays. Material and Methods: Six patients and one cadaver head were analyzed in this study. The cadaver-head dissection confirmed the location of the sphenopalatine ganglion on X-rays and CT imaging. One patient undergoing radiofrequency sphenopalatine ablation participated for confirmation of the location of the ganglion on plain X-rays. Five patients received radiosurgery of the sphenopalatine ganglion. One patient had classic unilateral cluster headache. Two patients had neuropathic pain and 1 had bilateral migrainous neuralgia. The fifth patient had bilateral atypical facial pain. All received a single maximal dose of 90 Gy with a 5- or 7.5-mm circular collimator. MRI, CT, and skull X-rays identified and confirmed the target. Results: The sphenopalatine fossa is seen in the skull X-ray as an inverse tear drop just caudal to the sphenoid sinus. This location is readily correlated to the CT target by the stereotactic coordinates and confirmed with the presence of the ganglion visualized in the MRI scan. Only the patient with cluster headache experienced lasting pain relief. Conclusion: Multiple imaging modalities confirmed the location of the sphenopalatine ganglion for radiosurgery. The procedure was performed safely with CT and MRI fusion. Radiosurgery was significantly beneficial only on classic cluster headache

  14. SU-D-BRB-04: Plan Quality Comparison of Intracranial Stereotactic Radiosurgery (SRS) for Gamma Knife and VMAT Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Keeling, V; Algan, O; Ahmad, S; Hossain, S [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2015-06-15

    Purpose: To compare treatment plan quality of intracranial stereotactic radiosurgery (SRS) for VMAT (RapidArc) and Gamma Knife (GK) systems. Methods: Ten patients with 24 tumors (seven with 1–2 and three with 4–6 lesions), previously treated with GK 4C (prescription doses ranging from 14–23 Gy) were re-planned for RapidArc. Identical contour sets were kept on MRI images for both plans with tissues assigned a CT number of zero. RapidArc plans were performed using 6 MV flattening-filter-free (FFF) beams with dose rate of 1400 MU/minute using two to eight arcs with the following combinations: 2 full coplanar arcs and the rest non-coplanar half arcs. Beam selection was based on target depth. Areas that penetrated more than 10 cm of tissue were avoided by creating smaller arcs or using avoidance sectors in optimization. Plans were optimized with jaw tracking and a high weighting to the normal-brain-tissue and Normal-Tissue-Objective without compromising PTV coverage. Plans were calculated on a 1 mm grid size using AAA algorithm and then normalized so that 99% of each target volume received the prescription dose. Plan quality was assessed by target coverage using Paddick Conformity Index (PCI), sparing of normal-brain-tissue through analysis of V4, V8, and V12 Gy, and integral dose. Results: In all cases critical structure dose criteria were met. RapidArc had a higher PCI than GK plans for 23 out of 24 lesions. The average PCI was 0.76±0.21 for RapidArc and 0.46±0.20 for GK plans (p≤0.001), respectively. Integral dose and normal-brain-tissue doses for all criteria were lower for RapidArc in nearly all patients. The average ratio of GK to RapidArc plans was 1.28±0.27 (p=0.018), 1.31±0.25 (p=0.017), 1.81±0.43 (p=0.005), and 1.50±0.61 (p=0.006) for V4, V8, and V12 Gy, and integral dose, respectively. Conclusion: VMAT was capable of producing higher quality treatment plans than GK when using optimal beam geometries and proper optimization techniques.

  15. A dosimetric comparison of fan-beam intensity modulated radiotherapy with gamma knife stereotactic radiosurgery for treating intermediate intracranial lesions

    International Nuclear Information System (INIS)

    Ma Lijun; Xia Ping; Verhey, Lynn J.; Boyer, Arthur L.

    1999-01-01

    Purpose: To compare and evaluate treatment plans for the fan-beam intensity modulated radiotherapy and the Gamma Knife radiosurgery for treating medium-size intracranial lesions (range 4-25 cm 3 ). Methods and Materials: Treatment plans were developed for the Leksell Gamma Knife and a fan-beam inverse treatment planning system for intensity modulated radiotherapy. Treatment plan comparisons were carried out using dose-volume histogram (DVH), tissue-volume ratio (TVR), and maximum dose to the prescription dose (MDPD) ratio. The study was carried out for both simulated targets and clinical targets with irregular shapes and at different locations. Results: The MDPD ratio was significantly greater for the Gamma Knife plans than for the fan-beam IMRT plans. The Gamma Knife plans produced equivalent TVR values to the fan-beam IMRT plans. Based on the DVH comparison, the fan-beam IMRT delivered significantly more dose to the normal brain tissue than the Gamma Knife. The results of the comparison were found to be insensitive to the target locations. Conclusion: The Gamma Knife is better than the fan-beam IMRT in sparing normal brain tissue while producing equivalent tumor dose conformity for treating medium-size intracranial lesions. However, the target dose homogeneity is significantly better for the fan-beam IMRT than for the Gamma Knife

  16. Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage

    International Nuclear Information System (INIS)

    Roper, Justin; Chanyavanich, Vorakarn; Betzel, Gregory; Switchenko, Jeffrey; Dhabaan, Anees

    2015-01-01

    Purpose: To determine the dosimetric effects of rotational errors on target coverage using volumetric modulated arc therapy (VMAT) for multitarget stereotactic radiosurgery (SRS). Methods and Materials: This retrospective study included 50 SRS cases, each with 2 intracranial planning target volumes (PTVs). Both PTVs were planned for simultaneous treatment to 21 Gy using a single-isocenter, noncoplanar VMAT SRS technique. Rotational errors of 0.5°, 1.0°, and 2.0° were simulated about all axes. The dose to 95% of the PTV (D95) and the volume covered by 95% of the prescribed dose (V95) were evaluated using multivariate analysis to determine how PTV coverage was related to PTV volume, PTV separation, and rotational error. Results: At 0.5° rotational error, D95 values and V95 coverage rates were ≥95% in all cases. For rotational errors of 1.0°, 7% of targets had D95 and V95 values 95% for only 63% of the targets. Multivariate analysis showed that PTV volume and distance to isocenter were strong predictors of target coverage. Conclusions: The effects of rotational errors on target coverage were studied across a broad range of SRS cases. In general, the risk of compromised coverage increased with decreasing target volume, increasing rotational error and increasing distance between targets. Multivariate regression models from this study may be used to quantify the dosimetric effects of rotational errors on target coverage given patient-specific input parameters of PTV volume and distance to isocenter.

  17. Multistage stereotactic radiosurgery for large cerebral arteriovenous malformations using the Gamma Knife platform.

    Science.gov (United States)

    Ding, Chuxiong; Hrycushko, Brian; Whitworth, Louis; Li, Xiang; Nedzi, Lucien; Weprin, Bradley; Abdulrahman, Ramzi; Welch, Babu; Jiang, Steve B; Wardak, Zabi; Timmerman, Robert D

    2017-10-01

    Radiosurgery is an established technique to treat cerebral arteriovenous malformations (AVMs). Obliteration of larger AVMs (> 10-15 cm 3 or diameter > 3 cm) in a single session is challenging with current radiosurgery platforms due to toxicity. We present a novel technique of multistage stereotactic radiosurgery (SRS) for large intracranial arteriovenous malformations (AVM) using the Gamma Knife system. Eighteen patients with large (> 10-15 cm 3 or diameter > 3 cm) AVMs, which were previously treated using a staged SRS technique on the Cyberknife platform, were retrospectively selected for this study. The AVMs were contoured and divided into 3-8 subtargets to be treated sequentially in a staged approach at half to 4 week intervals. The prescription dose ranged from 15 Gy to 20 Gy, depending on the subtarget number, volume, and location. Gamma Knife plans using multiple collimator settings were generated and optimized. The coordinates of each shot from the initial plan covering the total AVM target were extracted based on their relative positions within the frame system. The shots were regrouped based on their location with respect to the subtarget contours to generate subplans for each stage. The delivery time of each shot for a subtarget was decay corrected with 60 Co for staging the treatment course to generate the same dose distribution as that planned for the total AVM target. Conformality indices and dose-volume analysis were performed to evaluate treatment plans. With the shot redistribution technique, the composite dose for the multistaged treatment of multiple subtargets is equivalent to the initial plan for total AVM target. Gamma Knife plans resulted in an average PTV coverage of 96.3 ± 0.9% and a PITV of 1.23 ± 0.1. The resulting Conformality indices, V 12Gy and R 50 dose spillage values were 0.76 ± 0.05, 3.4 ± 1.8, and 3.1 ± 0.5 respectively. The Gamma Knife system can deliver a multistaged conformal dose to treat large AVMs when correcting for

  18. Stereotactic gamma radiosurgery of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Tatsuya; Kida, Yoshihisa; Tanaka, Takayuki; Oyama, Hirofumi; Yoshida, Kazuo; Maesawa, Satoshi; Kai, Osamu; Nakamura, Mototoshi; Arahata, Masashige [Komaki City Hospital, Aichi (Japan)

    1996-06-01

    One thousand cases with various head and neck diseases have been treated by gamma radiosurgery at Komaki City Hospital since May 1991. Five hundred and sixty-eight out of 1,000 cases were neoplastic lesions which consisted of 173 cases of neurinoma, 108 of metastatic tumors, 103 of meningioma, 69 of gliomas, 27 of pituitary adenoma, 26 of craniopharyngioma, 13 of pineal tumors, 11 of chordoma, 6 of malignant lymphoma, 5 of hemangioblastoma and so on. The most effective result has been shown in metastatic brain tumors. The complete response (disappearance of the lesion) was obtained in more than 50% of the treated lesions, and the control rate of 85% was maintained for more than 12 months. Next effective results were shown in craniopharyngioma, malignant pineal tumors and malignant lymphoma. There was a group which showed moderate response but no tumor disappearance. Those were pituitary adenoma, acoustic neurinoma, meningioma and chordoma. Gliomas showed less response and even progression of tumor at relatively higher rate. It has been found that malignant gliomas showed difficult control of the tumor and progression rate of 70%, while benign gliomas showed the control rate of more than 90%. Besides intracranial lesions, malignant skull base tumors such as chordoma, naso-pharyngeal cancer, adenoid cystic cancer showed better response to gamma radiosurgery and higher control rate for longer period of time with high QOL compaired to conventional irradiation. (author)

  19. Improvement of radiological penumbra using intermediate energy photons (IEP) for stereotactic radiosurgery

    International Nuclear Information System (INIS)

    O'Malley, Lauren; Pignol, Jean-Philippe; Beachey, David J; Keller, Brian M; Presutti, Joseph; Sharpe, Michael

    2006-01-01

    Using efficient immobilization and dedicated beam collimation devices, stereotactic radiosurgery ensures highly conformal treatment of small tumours with limited microscopic extension. One contribution to normal tissue irradiation remains the radiological penumbra. This work aims at demonstrating that intermediate energy photons (IEP), above orthovoltage but below megavoltage, improve dose distribution for stereotactic radiosurgery for small irradiation field sizes due to a dramatic reduction of radiological penumbra. Two different simulation systems were used: (i) Monte Carlo simulation to investigate the dose distribution of monoenergetic IEP between 100 keV and 1 MeV in water phantom; (ii) the Pinnacle 3 TPS including a virtual IEP unit to investigate the dosimetry benefit of treating with 11 non-coplanar beams a 2 cm tumour in the middle of a brain adjacent to a 1 mm critical structure. Radiological penumbrae below 300 μm are generated for field size below 2 x 2 cm 2 using monoenergetic IEP beams between 200 and 400 keV. An 800 kV beam generated in a 0.5 mm tungsten target maximizes the photon intensity in this range. Pinnacle 3 confirms the dramatic reduction in penumbra size. DVHs show for a constant dose distribution conformality, improved dose distribution homogeneity and better sparing of critical structures using a 800 kV beam compared to a 6 MV beam

  20. Improvement of radiological penumbra using intermediate energy photons (IEP) for stereotactic radiosurgery

    Science.gov (United States)

    O'Malley, Lauren; Pignol, Jean-Philippe; Beachey, David J.; Keller, Brian M.; Presutti, Joseph; Sharpe, Michael

    2006-05-01

    Using efficient immobilization and dedicated beam collimation devices, stereotactic radiosurgery ensures highly conformal treatment of small tumours with limited microscopic extension. One contribution to normal tissue irradiation remains the radiological penumbra. This work aims at demonstrating that intermediate energy photons (IEP), above orthovoltage but below megavoltage, improve dose distribution for stereotactic radiosurgery for small irradiation field sizes due to a dramatic reduction of radiological penumbra. Two different simulation systems were used: (i) Monte Carlo simulation to investigate the dose distribution of monoenergetic IEP between 100 keV and 1 MeV in water phantom; (ii) the Pinnacle3 TPS including a virtual IEP unit to investigate the dosimetry benefit of treating with 11 non-coplanar beams a 2 cm tumour in the middle of a brain adjacent to a 1 mm critical structure. Radiological penumbrae below 300 µm are generated for field size below 2 × 2 cm2 using monoenergetic IEP beams between 200 and 400 keV. An 800 kV beam generated in a 0.5 mm tungsten target maximizes the photon intensity in this range. Pinnacle3 confirms the dramatic reduction in penumbra size. DVHs show for a constant dose distribution conformality, improved dose distribution homogeneity and better sparing of critical structures using a 800 kV beam compared to a 6 MV beam.

  1. Stereotactic Radiosurgery and Fractionated Stereotactic Radiation Therapy for the Treatment of Uveal Melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Yazici, Gozde [Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Kiratli, Hayyam [Department of Ophthalmology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Ozyigit, Gokhan; Sari, Sezin Yuce; Cengiz, Mustafa [Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Tarlan, Bercin [Bascom Palmer Eye Institute, Miami, Florida (United States); Mocan, Burce Ozgen [Department of Radiology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Zorlu, Faruk, E-mail: fzorlu@hacettepe.edu.tr [Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara (Turkey)

    2017-05-01

    Purpose: To evaluate treatment results of stereotactic radiosurgery or fractionated stereotactic radiation therapy (SRS/FSRT) for uveal melanoma. Methods and Materials: We retrospectively evaluated 181 patients with 182 uveal melanomas receiving SRS/FSRT between 2007 and 2013. Treatment was administered with CyberKnife. Results: According to Collaborative Ocular Melanoma Study criteria, tumor size was small in 1%, medium in 49.5%, and large in 49.5% of the patients. Seventy-one tumors received <45 Gy, and 111 received ≥45 Gy. Median follow-up time was 24 months. Complete and partial response was observed in 8 and 104 eyes, respectively. The rate of 5-year overall survival was 98%, disease-free survival 57%, local recurrence-free survival 73%, distant metastasis-free survival 69%, and enucleation-free survival 73%. There was a significant correlation between tumor size and disease-free survival, SRS/FSRT dose and enucleation-free survival; and both were prognostic for local recurrence-free survival. Enucleation was performed in 41 eyes owing to progression in 26 and complications in 11. Conclusions: The radiation therapy dose is of great importance for local control and eye retention; the best treatment outcome was achieved using ≥45 Gy in 3 fractions.

  2. Stereotactic Radiosurgery and Fractionated Stereotactic Radiation Therapy for the Treatment of Uveal Melanoma

    International Nuclear Information System (INIS)

    Yazici, Gozde; Kiratli, Hayyam; Ozyigit, Gokhan; Sari, Sezin Yuce; Cengiz, Mustafa; Tarlan, Bercin; Mocan, Burce Ozgen; Zorlu, Faruk

    2017-01-01

    Purpose: To evaluate treatment results of stereotactic radiosurgery or fractionated stereotactic radiation therapy (SRS/FSRT) for uveal melanoma. Methods and Materials: We retrospectively evaluated 181 patients with 182 uveal melanomas receiving SRS/FSRT between 2007 and 2013. Treatment was administered with CyberKnife. Results: According to Collaborative Ocular Melanoma Study criteria, tumor size was small in 1%, medium in 49.5%, and large in 49.5% of the patients. Seventy-one tumors received <45 Gy, and 111 received ≥45 Gy. Median follow-up time was 24 months. Complete and partial response was observed in 8 and 104 eyes, respectively. The rate of 5-year overall survival was 98%, disease-free survival 57%, local recurrence-free survival 73%, distant metastasis-free survival 69%, and enucleation-free survival 73%. There was a significant correlation between tumor size and disease-free survival, SRS/FSRT dose and enucleation-free survival; and both were prognostic for local recurrence-free survival. Enucleation was performed in 41 eyes owing to progression in 26 and complications in 11. Conclusions: The radiation therapy dose is of great importance for local control and eye retention; the best treatment outcome was achieved using ≥45 Gy in 3 fractions.

  3. A concise review of the efficacy of stereotactic radiosurgery in the management of melanoma and renal cell carcinoma brain metastases

    Directory of Open Access Journals (Sweden)

    Hanson Peter W

    2012-08-01

    Full Text Available Abstract Melanoma and renal cell carcinoma have a well-documented tendency to develop metastases to the brain. Treating these lesions has traditionally been problematic, because chemotherapy has difficulty crossing the blood brain barrier and whole brain radiation therapy (WBRT is a relatively ineffective treatment against these radioresistant tumor histologies. In recent years, stereotactic radiosurgery (SRS has emerged as an effective and minimally-invasive treatment modality for irradiating either single or multiple intracranial structures in one clinical treatment setting. For this reason, we conducted a review of modern literature analyzing the efficacy of SRS in the management of patients with melanoma and renal cell carcinoma brain metastases. In our analysis we found SRS to be a safe, effective and attractive treatment modality for managing radioresistant brain metastases and highlighted the need for randomized trials comparing WBRT alone vs. SRS alone vs. WBRT plus SRS in treating patients with radioresistant brain metastases.

  4. International Spine Radiosurgery Consortium Consensus Guidelines for Target Volume Definition in Spinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Cox, Brett W.; Spratt, Daniel E.; Lovelock, Michael; Bilsky, Mark H.; Lis, Eric; Ryu, Samuel; Sheehan, Jason; Gerszten, Peter C.; Chang, Eric; Gibbs, Iris; Soltys, Scott; Sahgal, Arjun; Deasy, Joe; Flickinger, John; Quader, Mubina; Mindea, Stefan

    2012-01-01

    Purpose: Spinal stereotactic radiosurgery (SRS) is increasingly used to manage spinal metastases. However, target volume definition varies considerably and no consensus target volume guidelines exist. This study proposes consensus target volume definitions using common scenarios in metastatic spine radiosurgery. Methods and Materials: Seven radiation oncologists and 3 neurological surgeons with spinal radiosurgery expertise independently contoured target and critical normal structures for 10 cases representing common scenarios in metastatic spine radiosurgery. Each set of volumes was imported into the Computational Environment for Radiotherapy Research. Quantitative analysis was performed using an expectation maximization algorithm for Simultaneous Truth and Performance Level Estimation (STAPLE) with kappa statistics calculating agreement between physicians. Optimized confidence level consensus contours were identified using histogram agreement analysis and characterized to create target volume definition guidelines. Results: Mean STAPLE agreement sensitivity and specificity was 0.76 (range, 0.67-0.84) and 0.97 (range, 0.94-0.99), respectively, for gross tumor volume (GTV) and 0.79 (range, 0.66-0.91) and 0.96 (range, 0.92-0.98), respectively, for clinical target volume (CTV). Mean kappa agreement was 0.65 (range, 0.54-0.79) for GTV and 0.64 (range, 0.54-0.82) for CTV (P<.01 for GTV and CTV in all cases). STAPLE histogram agreement analysis identified optimal consensus contours (80% confidence limit). Consensus recommendations include that the CTV should include abnormal marrow signal suspicious for microscopic invasion and an adjacent normal bony expansion to account for subclinical tumor spread in the marrow space. No epidural CTV expansion is recommended without epidural disease, and circumferential CTVs encircling the cord should be used only when the vertebral body, bilateral pedicles/lamina, and spinous process are all involved or there is extensive metastatic

  5. A Review of Stereotactic Radiosurgery Practice in the Management of Skull Base Meningiomas

    OpenAIRE

    Vera, Elena; Iorgulescu, J. Bryan; Raper, Daniel M.S.; Madhavan, Karthik; Lally, Brian E.; Morcos, Jacques; Elhammady, Samy; Sherman, Jonathan; Komotar, Ricardo J.

    2014-01-01

    Gross total resection of skull base meningiomas poses a surgical challenge due to their proximity to neurovascular structures. Once the gold standard therapy for skull base meningiomas, microsurgery has been gradually replaced by or used in combination with stereotactic radiosurgery (SRS). This review surveys the safety and efficacy of SRS in the treatment of cranial base meningiomas including 36 articles from 1991 to 2010. SRS produces excellent tumor control with low morbidity rates compare...

  6. Nelson's syndrome: single centre experience using the linear accelerator (LINAC) for stereotactic radiosurgery and fractionated stereotactic radiotherapy.

    Science.gov (United States)

    Wilson, Peter J; Williams, Janet R; Smee, Robert I

    2014-09-01

    Nelson's syndrome is a unique clinical phenomenon of growth of a pituitary adenoma following bilateral adrenalectomies for the control of Cushing's disease. Primary management is surgical, with limited effective medical therapies available. We report our own institution's series of this pathology managed with radiation: prior to 1990, 12 patients were managed with conventional radiotherapy, and between 1990 and 2007, five patients underwent stereotactic radiosurgery (SRS) and two patients fractionated stereotactic radiotherapy (FSRT), both using the linear accelerator (LINAC). Tumour control was equivocal, with two of the five SRS patients having a reduction in tumour volume, one patient remaining unchanged, and two patients having an increase in volume. In the FSRT group, one patient had a decrease in tumour volume whilst the other had an increase in volume. Treatment related morbidity was low. Nelson's syndrome is a challenging clinical scenario, with a highly variable response to radiation in our series. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Optimal technique of linear accelerator–based stereotactic radiosurgery for tumors adjacent to brainstem

    International Nuclear Information System (INIS)

    Chang, Chiou-Shiung; Hwang, Jing-Min; Tai, Po-An; Chang, You-Kang; Wang, Yu-Nong; Shih, Rompin; Chuang, Keh-Shih

    2016-01-01

    Stereotactic radiosurgery (SRS) is a well-established technique that is replacing whole-brain irradiation in the treatment of intracranial lesions, which leads to better preservation of brain functions, and therefore a better quality of life for the patient. There are several available forms of linear accelerator (LINAC)–based SRS, and the goal of the present study is to identify which of these techniques is best (as evaluated by dosimetric outcomes statistically) when the target is located adjacent to brainstem. We collected the records of 17 patients with lesions close to the brainstem who had previously been treated with single-fraction radiosurgery. In all, 5 different lesion catalogs were collected, and the patients were divided into 2 distance groups—1 consisting of 7 patients with a target-to-brainstem distance of less than 0.5 cm, and the other of 10 patients with a target-to-brainstem distance of ≥ 0.5 and < 1 cm. Comparison was then made among the following 3 types of LINAC-based radiosurgery: dynamic conformal arcs (DCA), intensity-modulated radiosurgery (IMRS), and volumetric modulated arc radiotherapy (VMAT). All techniques included multiple noncoplanar beams or arcs with or without intensity-modulated delivery. The volume of gross tumor volume (GTV) ranged from 0.2 cm 3 to 21.9 cm 3 . Regarding the dose homogeneity index (HI ICRU ) and conformity index (CI ICRU ) were without significant difference between techniques statistically. However, the average CI ICRU = 1.09 ± 0.56 achieved by VMAT was the best of the 3 techniques. Moreover, notable improvement in gradient index (GI) was observed when VMAT was used (0.74 ± 0.13), and this result was significantly better than those achieved by the 2 other techniques (p < 0.05). For V 4 Gy of brainstem, both VMAT (2.5%) and IMRS (2.7%) were significantly lower than DCA (4.9%), both at the p < 0.05 level. Regarding V 2 Gy of normal brain, VMAT plans had attained 6.4 ± 5%; this was significantly better

  8. "Cor Occidere": a novel strategy of targeting the tumor core by radiosurgery in a radio- and chemo-resistant intracranial hemangiopericytoma.

    Science.gov (United States)

    Li, You Quan; Chua, Eu Tiong; Chua, Kevin L M; Chua, Melvin L K

    2018-02-01

    Intracranial hemangiopericytomas (HPC) are chemotherapy- and radiotherapy (RT)-resistant. Here, we report on a novel stereotactic radiosurgery (SRS) technique-"Cor Occidere" (Latin), as a potential strategy of overcoming radioresistance of HPC. A 36-year old female presented to our clinic for consideration of a 3rd-course of RT for her recurrent cavernous sinus HPC, following previous cranial RT at 13 and 5 years prior, and a failed 9 months trial of bevacizumab/temozolomide. The tumor-adjacent brain stem and carotid artery risked substantial damage given the cumulative RT doses to these organs. We therefore designed an SRS plan targeting only the tumor core with 16 Gy single-fraction. Despite underdosing the tumor margin, we achieved stable disease over 25 months, contrasting her responses to systemic therapies. Achieving tumor control despite a suboptimal treatment that utilized high dose ablation of the tumor core suggests novel biological mechanisms to overcome radioresistance of HPC.

  9. Brain tumor radiosurgery. Current status and strategies to enhance the effect of radiosurgery

    International Nuclear Information System (INIS)

    Niranjan, A.; Lunsford, L.D.; Gobbel, G.T.; Kondziolka, D.; Maitz, A.; Flickinger, J.C.

    2000-01-01

    First, the current status of brain tumor radiosurgery is reviewed, and radiosurgery for brain tumors, including benign tumors, malignant tumors, primary glial tumors, and metastatic tumors, is described. Rapid developments in neuroimaging, stereotactic techniques, and robotic technology in the last decade have contributed to improved results and wider applications of radiosurgery. Radiosurgery has become the preferred management modality for many intracranial tumors, including schwannomas, meningiomas, and metastatic tumors. Although radiosurgery provides survival benefits in patients with diffuse malignant brain tumors, cure is still not possible. Microscopic tumor infiltration into surrounding normal tissue is the main cause of recurrence. Additional strategies are needed to specifically target tumor cells. Next, strategies to enhance the effect of radiosurgery are reviewed. Whereas the long-term clinical results of radiosurgery have established its role in the treatment of benign tumors, additional strategies are needed to improve cell killing in malignant brain tumors and to protect normal surrounding brain. The first strategy included the use of various agents to protect normal brain while delivering a high dose to the tumor cells, but finding an effective radioprotective agent has been problematic. Pentobarbital and 21-aminosteroid (21-AS) are presented as examples. The second strategy for radiation protection aimed at the repair of radiation-induced damage to the normal brain. The cause of radiation-induced breakdown of normal tissue is unclear. The white matter and the cerebral vasculature appear to be particularly susceptible to radiation. Oligodendrocytes and endothelial cells may be critical targets of radiation. The authors hypothesize that radiation-induced damage to these cell types can be repaired by neural stem cells. They also describe the use of tumor necrosis factor alpha (TNF-alpha) and neural stem cells as a means of enhancing the effect of

  10. Evaluation of radiosurgery techniques–Cone-based linac radiosurgery vs tomotherapy-based radiosurgery

    International Nuclear Information System (INIS)

    Yip, Ho Yin; Mui, Wing Lun A.; Lee, Joseph W.Y.; Fung, Winky Wing Ki; Chan, Jocelyn M.T.; Chiu, G.; Law, Maria Y.Y.

    2013-01-01

    Performances of radiosurgery of intracranial lesions between cone-based Linac system and Tomotherapy-based system were compared in terms of dosimetry and time. Twelve patients with single intracranial lesion treated with cone-based Linac radiosurgery system from 2005 to 2009 were replanned for Tomotherapy-based radiosurgery treatment. The conformity index, homogeneity index (HI), and gradient score index (GSI) of each case was calculated. The Wilcoxon matched-pair test was used to compare the 3 indices between both systems. The cases with regular target (n = 6) and those with irregular target (n = 6) were further analyzed separately. The estimated treatment time between both systems was also compared. Significant differences were found in HI (p = 0.05) and in GSI (p = 0.03) for the whole group. Cone-based radiosurgery was better in GSI whereas Tomotherapy-based radiosurgery was better in HI. Cone-based radiosurgery was better in conformity index (p = 0.03) and GSI (p = 0.03) for regular targets, whereas Tomotherapy-based radiosurgery system performed significantly better in HI (p = 0.03) for irregular targets. The estimated total treatment time for Tomotherapy-based radiosurgery ranged from 24 minutes to 35 minutes, including 15 minutes of pretreatment megavoltage computed tomography (MVCT) and image registration, whereas that for cone-based radiosurgery ranged from 15 minutes for 1 isocenter to 75 minutes for 5 isocenters. As a rule of thumb, Tomotherapy-based radiosurgery system should be the first-line treatment for irregular lesions because of better dose homogeneity and shorter treatment time. Cone-based Linac radiosurgery system should be the treatment of choice for regular targets because of the better dose conformity, rapid dose fall-off, and reasonable treatment time

  11. Evaluation of radiosurgery techniques–Cone-based linac radiosurgery vs tomotherapy-based radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Yip, Ho Yin, E-mail: hoyinyip@yahoo.com.hk [Department of Radiotherapy, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong (China); Mui, Wing Lun A.; Lee, Joseph W.Y.; Fung, Winky Wing Ki; Chan, Jocelyn M.T.; Chiu, G. [Department of Radiotherapy, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong (China); Law, Maria Y.Y. [Medical Physics and Research Department, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong (China)

    2013-07-01

    Performances of radiosurgery of intracranial lesions between cone-based Linac system and Tomotherapy-based system were compared in terms of dosimetry and time. Twelve patients with single intracranial lesion treated with cone-based Linac radiosurgery system from 2005 to 2009 were replanned for Tomotherapy-based radiosurgery treatment. The conformity index, homogeneity index (HI), and gradient score index (GSI) of each case was calculated. The Wilcoxon matched-pair test was used to compare the 3 indices between both systems. The cases with regular target (n = 6) and those with irregular target (n = 6) were further analyzed separately. The estimated treatment time between both systems was also compared. Significant differences were found in HI (p = 0.05) and in GSI (p = 0.03) for the whole group. Cone-based radiosurgery was better in GSI whereas Tomotherapy-based radiosurgery was better in HI. Cone-based radiosurgery was better in conformity index (p = 0.03) and GSI (p = 0.03) for regular targets, whereas Tomotherapy-based radiosurgery system performed significantly better in HI (p = 0.03) for irregular targets. The estimated total treatment time for Tomotherapy-based radiosurgery ranged from 24 minutes to 35 minutes, including 15 minutes of pretreatment megavoltage computed tomography (MVCT) and image registration, whereas that for cone-based radiosurgery ranged from 15 minutes for 1 isocenter to 75 minutes for 5 isocenters. As a rule of thumb, Tomotherapy-based radiosurgery system should be the first-line treatment for irregular lesions because of better dose homogeneity and shorter treatment time. Cone-based Linac radiosurgery system should be the treatment of choice for regular targets because of the better dose conformity, rapid dose fall-off, and reasonable treatment time.

  12. Knowledge-based prediction of plan quality metrics in intracranial stereotactic radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Shiraishi, Satomi; Moore, Kevin L., E-mail: kevinmoore@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California 92093 (United States); Tan, Jun [Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, Texas 75490 (United States); Olsen, Lindsey A. [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110 (United States)

    2015-02-15

    Purpose: The objective of this work was to develop a comprehensive knowledge-based methodology for predicting achievable dose–volume histograms (DVHs) and highly precise DVH-based quality metrics (QMs) in stereotactic radiosurgery/radiotherapy (SRS/SRT) plans. Accurate QM estimation can identify suboptimal treatment plans and provide target optimization objectives to standardize and improve treatment planning. Methods: Correlating observed dose as it relates to the geometric relationship of organs-at-risk (OARs) to planning target volumes (PTVs) yields mathematical models to predict achievable DVHs. In SRS, DVH-based QMs such as brain V{sub 10Gy} (volume receiving 10 Gy or more), gradient measure (GM), and conformity index (CI) are used to evaluate plan quality. This study encompasses 223 linear accelerator-based SRS/SRT treatment plans (SRS plans) using volumetric-modulated arc therapy (VMAT), representing 95% of the institution’s VMAT radiosurgery load from the past four and a half years. Unfiltered models that use all available plans for the model training were built for each category with a stratification scheme based on target and OAR characteristics determined emergently through initial modeling process. Model predictive accuracy is measured by the mean and standard deviation of the difference between clinical and predicted QMs, δQM = QM{sub clin} − QM{sub pred}, and a coefficient of determination, R{sup 2}. For categories with a large number of plans, refined models are constructed by automatic elimination of suspected suboptimal plans from the training set. Using the refined model as a presumed achievable standard, potentially suboptimal plans are identified. Predictions of QM improvement are validated via standardized replanning of 20 suspected suboptimal plans based on dosimetric predictions. The significance of the QM improvement is evaluated using the Wilcoxon signed rank test. Results: The most accurate predictions are obtained when plans are

  13. Knowledge-based prediction of plan quality metrics in intracranial stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Shiraishi, Satomi; Moore, Kevin L.; Tan, Jun; Olsen, Lindsey A.

    2015-01-01

    Purpose: The objective of this work was to develop a comprehensive knowledge-based methodology for predicting achievable dose–volume histograms (DVHs) and highly precise DVH-based quality metrics (QMs) in stereotactic radiosurgery/radiotherapy (SRS/SRT) plans. Accurate QM estimation can identify suboptimal treatment plans and provide target optimization objectives to standardize and improve treatment planning. Methods: Correlating observed dose as it relates to the geometric relationship of organs-at-risk (OARs) to planning target volumes (PTVs) yields mathematical models to predict achievable DVHs. In SRS, DVH-based QMs such as brain V 10Gy (volume receiving 10 Gy or more), gradient measure (GM), and conformity index (CI) are used to evaluate plan quality. This study encompasses 223 linear accelerator-based SRS/SRT treatment plans (SRS plans) using volumetric-modulated arc therapy (VMAT), representing 95% of the institution’s VMAT radiosurgery load from the past four and a half years. Unfiltered models that use all available plans for the model training were built for each category with a stratification scheme based on target and OAR characteristics determined emergently through initial modeling process. Model predictive accuracy is measured by the mean and standard deviation of the difference between clinical and predicted QMs, δQM = QM clin − QM pred , and a coefficient of determination, R 2 . For categories with a large number of plans, refined models are constructed by automatic elimination of suspected suboptimal plans from the training set. Using the refined model as a presumed achievable standard, potentially suboptimal plans are identified. Predictions of QM improvement are validated via standardized replanning of 20 suspected suboptimal plans based on dosimetric predictions. The significance of the QM improvement is evaluated using the Wilcoxon signed rank test. Results: The most accurate predictions are obtained when plans are stratified based on

  14. SU-E-T-453: Optimization of Dose Gradient for Gamma Knife Radiosurgery.

    Science.gov (United States)

    Sheth, N; Chen, Y; Yang, J

    2012-06-01

    The goals of stereotactic radiosurgery (SRS) are the ablation of target tissue and sparing of critical normal tissue. We develop tools to aid in the selection of collimation and prescription (Rx) isodose line to optimize the dose gradient for single isocenter intracranial stereotactic radiosurgery (SRS) with GammaKnife 4C utilizing the updated physics data in GammaPlan v10.1. Single isocenter intracranial SRS plans were created to treat the center of a solid water anthropomorphism head phantom for each GammaKnife collimator (4 mm, 8 mm, 14 mm, and 18 mm). The dose gradient, defined as the difference of effective radii of spheres equal to half and full Rx volumes, and Rx treatment volume was analyzed for isodoses from 99% to 20% of Rx. The dosimetric data on Rx volume and dose gradient vs. Rx isodose for each collimator was compiled into an easy to read nomogram as well as plotted graphically. The 4, 8, 14, and 18 mm collimators have the sharpest dose gradient at the 64%, 70%, 76%, and 77% Rx isodose lines, respectively. This corresponds to treating 4.77 mm, 8.86 mm, 14.78 mm, and 18.77 mm diameter targets with dose gradients radii of 1.06 mm, 1.63 mm, 2.54 mm, and 3.17 mm, respectively. We analyzed the dosimetric data for the most recent version of GammaPlan treatment planning software to develop tools that when applied clinically will aid in the selection of a collimator and Rx isodose line for optimal dose gradient and target coverage for single isocenter intracranial SRS with GammaKnife 4C. © 2012 American Association of Physicists in Medicine.

  15. Prescription Dose Guideline Based on Physical Criterion for Multiple Metastatic Brain Tumors Treated With Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Sahgal, Arjun; Barani, Igor J.; Novotny, Josef; Zhang Beibei; Petti, Paula; Larson, David A.; Ma Lijun

    2010-01-01

    Purpose: Existing dose guidelines for intracranial stereotactic radiosurgery (SRS) are primarily based on single-target treatment data. This study investigated dose guidelines for multiple targets treated with SRS. Methods and Materials: A physical model was developed to relate the peripheral isodose volume dependence on an increasing number of targets and prescription dose per target. The model was derived from simulated and clinical multiple brain metastatic cases treated with the Leksell Gamma Knife Perfexion at several institutions, where the total number of targets ranged from 2 to 60. The relative increase in peripheral isodose volumes, such as the 12-Gy volume, was studied in the multitarget treatment setting based on Radiation Therapy Oncology Group 90-05 study dose levels. Results: A significant increase in the 12-Gy peripheral isodose volumes was found in comparing multiple target SRS to single-target SRS. This increase strongly correlated (R 2 = 0.92) with the total number of targets but not the total target volumes (R 2 = 0.06). On the basis of the correlated curve, the 12-Gy volume for multiple target treatment was found to increase by approximately 1% per target when a low target dose such as 15 Gy was used, but approximately 4% per target when a high dose such as 20-24 Gy was used. Reduction in the prescription dose was quantified for each prescription level in maintaining the 12-Gy volume. Conclusion: Normal brain dose increases predictably with increasing number of targets for multitarget SRS. A reduction of approximately 1-2 Gy in the prescribed dose is needed compared with single target radiosurgery.

  16. A quality assurance program in stereotactic radiosurgery using the gamma knife unit

    International Nuclear Information System (INIS)

    Stuecklschweiger, G.F.; Feichtinger, K.

    1998-01-01

    Because of the large single fraction dose in stereotactic radiosurgery it is important to guarantee a high geometric and dosimetric accuracy. The paper represent the quality assurance program for the Gamma Knife unit at the University Clinic of Neurosurgery in Graz. The program includes the following procedures: Timer control, mechanical radiation isocenter coincidence, trunnion centricity, helmet microswitches test, radiation output and relative helmet factors, dose profile verification, safety interlocks checks and software quality assurance. In summary, the mechanical accuracy and reproducibility of the Gamma Knife unit are [de

  17. Cushing's disease: a single centre's experience using the linear accelerator (LINAC) for stereotactic radiosurgery and fractionated stereotactic radiotherapy.

    Science.gov (United States)

    Wilson, P J; Williams, J R; Smee, R I

    2014-01-01

    Cushing's disease is hypercortisolaemia secondary to an adrenocorticotrophic hormone secreting pituitary adenoma. Primary management is almost always surgical, with limited effective medical interventions available. Adjuvant therapy in the form of radiation is gaining popularity, with the bulk of the literature related to the Gamma Knife. We present the results from our own institution using the linear accelerator (LINAC) since 1990. Thirty-six patients who underwent stereotactic radiosurgery (SRS), one patient who underwent fractionated stereotactic radiotherapy (FSRT) and for the purposes of comparison, 13 patients who had undergone conventional radiotherapy prior to 1990, were included in the analysis. Serum cortisol levels improved in nine of 36 (25%) SRS patients and 24 hour urinary free cortisol levels improved in 13 of 36 patients (36.1%). Tumour volume control was excellent in the SRS group with deterioration in only one patient (3%). The patient who underwent FSRT had a highly aggressive tumour refractory to radiation. Published by Elsevier Ltd.

  18. Dose delivery verification and accuracy assessment of stereotaxy in stereotactic radiotherapy and radiosurgery

    International Nuclear Information System (INIS)

    Pelagade, S.M.; Bopche, T.T.; Namitha, K.; Munshi, M.; Bhola, S.; Sharma, H.; Patel, B.K.; Vyas, R.K.

    2008-01-01

    The outcome of stereotactic radiotherapy (SRT) and stereotactic radiosurgery (SRS) in both benign and malignant tumors within the cranial region highly depends on precision in dosimetry, dose delivery and the accuracy assessment of stereotaxy associated with the unit. The frames BRW (Brown-Roberts-Wells) and GTC (Gill- Thomas-Cosman) can facilitate accurate patient positioning as well as precise targeting of tumours. The implementation of this technique may result in a significant benefit as compared to conventional therapy. As the target localization accuracy is improved, the demand for treatment planning accuracy of a TPS is also increased. The accuracy of stereotactic X Knife treatment planning system has two components to verify: (i) the dose delivery verification and the accuracy assessment of stereotaxy; (ii) to ensure that the Cartesian coordinate system associated is well established within the TPS for accurate determination of a target position. Both dose delivery verification and target positional accuracy affect dose delivery accuracy to a defined target. Hence there is a need to verify these two components in quality assurance protocol. The main intention of this paper is to present our dose delivery verification procedure using cylindrical wax phantom and accuracy assessment (target position) of stereotaxy using Geometric Phantom on Elekta's Precise linear accelerator for stereotactic installation

  19. The Use of Cone Beam Computed Tomography for Image Guided Gamma Knife Stereotactic Radiosurgery: Initial Clinical Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Winnie; Cho, Young-Bin [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Ansell, Steve [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Laperriere, Normand; Ménard, Cynthia; Millar, Barbara-Ann [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Zadeh, Gelareh [Division of Neurosurgery, University of Toronto University Health Network, Toronto Western Hospital, Toronto, Ontario (Canada); Macfeeters-Hamilton Centre for Neuro-oncology, Ontario Cancer Institute, Toronto, Ontario (Canada); Kongkham, Paul; Bernstein, Mark [Division of Neurosurgery, University of Toronto University Health Network, Toronto Western Hospital, Toronto, Ontario (Canada); Jaffray, David A. [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Department of Medical Biophysics, University of Toronto, Toronto, Ontario (Canada); Chung, Caroline, E-mail: caroline.chung.md@gmail.com [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada)

    2016-09-01

    Purpose: The present study used cone beam computed tomography (CBCT) to measure the inter- and intrafraction uncertainties for intracranial stereotactic radiosurgery (SRS) using the Leksell Gamma Knife (GK). Methods and Materials: Using a novel CBCT system adapted to the GK radiosurgery treatment unit, CBCT images were acquired immediately before and after treatment for each treatment session within the context of a research ethics board–approved prospective clinical trial. Patients were immobilized in the Leksell coordinate frame (LCF) for both volumetric CBCT imaging and GK-SRS delivery. The relative displacement of the patient's skull to the stereotactic reference (interfraction motion) was measured for each CBCT scan. Differences between the pre- and post-treatment CBCT scans were used to determine the intrafraction motion. Results: We analyzed 20 pre- and 17 post-treatment CBCT scans in 20 LCF patients treated with SRS. The mean translational pretreatment setup error ± standard deviation in the left-right, anteroposterior, and craniocaudal directions was −0.19 ± 0.32, 0.06 ± 0.27, and −0.23 ± 0.2 mm, with a maximum of −0.74, −0.53, and −0.68 mm, respectively. After an average time between the pre- and post-treatment CBCT scans of 82 minutes (range 27-170), the mean intrafraction error ± standard deviation for the LCF was −0.03 ± 0.05, −0.03 ± 0.18, and −0.03 ± 0.12 mm in the left-right, anteroposterior, and craniocaudual direction, respectively. Conclusions: Using CBCT on a prototype image guided GK Perfexion unit, we were able to measure the inter- and intrafraction positional changes for GK-SRS using the invasive frame. In the era of image guided radiation therapy, the use of CBCT image guidance for both frame- and non–frame-based immobilization systems could serve as a useful quality assurance tool. Our preliminary measurements can guide the application of achievable thresholds for inter- and intrafraction

  20. The Use of Cone Beam Computed Tomography for Image Guided Gamma Knife Stereotactic Radiosurgery: Initial Clinical Evaluation

    International Nuclear Information System (INIS)

    Li, Winnie; Cho, Young-Bin; Ansell, Steve; Laperriere, Normand; Ménard, Cynthia; Millar, Barbara-Ann; Zadeh, Gelareh; Kongkham, Paul; Bernstein, Mark; Jaffray, David A.; Chung, Caroline

    2016-01-01

    Purpose: The present study used cone beam computed tomography (CBCT) to measure the inter- and intrafraction uncertainties for intracranial stereotactic radiosurgery (SRS) using the Leksell Gamma Knife (GK). Methods and Materials: Using a novel CBCT system adapted to the GK radiosurgery treatment unit, CBCT images were acquired immediately before and after treatment for each treatment session within the context of a research ethics board–approved prospective clinical trial. Patients were immobilized in the Leksell coordinate frame (LCF) for both volumetric CBCT imaging and GK-SRS delivery. The relative displacement of the patient's skull to the stereotactic reference (interfraction motion) was measured for each CBCT scan. Differences between the pre- and post-treatment CBCT scans were used to determine the intrafraction motion. Results: We analyzed 20 pre- and 17 post-treatment CBCT scans in 20 LCF patients treated with SRS. The mean translational pretreatment setup error ± standard deviation in the left-right, anteroposterior, and craniocaudal directions was −0.19 ± 0.32, 0.06 ± 0.27, and −0.23 ± 0.2 mm, with a maximum of −0.74, −0.53, and −0.68 mm, respectively. After an average time between the pre- and post-treatment CBCT scans of 82 minutes (range 27-170), the mean intrafraction error ± standard deviation for the LCF was −0.03 ± 0.05, −0.03 ± 0.18, and −0.03 ± 0.12 mm in the left-right, anteroposterior, and craniocaudual direction, respectively. Conclusions: Using CBCT on a prototype image guided GK Perfexion unit, we were able to measure the inter- and intrafraction positional changes for GK-SRS using the invasive frame. In the era of image guided radiation therapy, the use of CBCT image guidance for both frame- and non–frame-based immobilization systems could serve as a useful quality assurance tool. Our preliminary measurements can guide the application of achievable thresholds for inter- and intrafraction

  1. Alignment verification in stereotactic radiosurgery with use of graphic arts film

    International Nuclear Information System (INIS)

    Sweet, J.; Lamba, M.

    1990-01-01

    This paper evaluates the use of graphic arts film for field alignment verification of linear accelerator-based stereotactic radiosurgery. The characteristic curve was generated for Fuji RO-100 graphic arts film in a standard leaded radiation therapy cassette at 6 MV. The linear portion of the curve and the film contrast are presented and their clinical advantages discussed. The high contrast of this graphic arts film improves visualization of the 5-mm ball bearing (simulated target) in small, circular treatment fields. Comparison with standard port film demonstrates the large linear range of the graphic arts film, which proved useful in visualization of the simulated target within the small, circular treatment field

  2. Gold nanoparticle enhancement of stereotactic radiosurgery for neovascular age-related macular degeneration

    Science.gov (United States)

    Ngwa, Wilfred; Makrigiorgos, G. Mike; Berbeco, Ross I.

    2012-10-01

    Age-related macular degeneration (AMD) is the leading cause of blindness in developed countries for people over the age of 50. In this work, the dosimetric feasibility of using gold nanoparticles (AuNP) as radiosensitizers to enhance kilovoltage stereotactic radiosurgery for neovascular AMD is investigated. Microdosimetry calculations at the sub-cellular level were carried out to estimate the radiation dose enhancement to individual nuclei in neovascular AMD endothelial cells (nDEF) due to photon-induced photo-/Auger electrons from x-ray-irradiated AuNP. The nDEF represents the ratio of radiation doses to the endothelial cell nuclei with and without AuNP. The calculations were carried out for a range of feasible AuNP local concentrations using the clinically applicable 100 kVp x-ray beam parameters employed by a commercially available x-ray therapy system. The results revealed nDEF values of 1.30-3.26 for the investigated concentration range of 1-7 mg g-1, respectively. In comparison, for the same concentration range, nDEF values of 1.32-3.40, 1.31-3.33, 1.29-3.19, 1.28-3.12 were calculated for 80, 90, 110 and 120 kVp x-rays, respectively. Meanwhile, calculations as a function of distance from the AuNP showed that the dose enhancement, for 100 kVp, is markedly confined to the targeted neovascular AMD endothelial cells where AuNP are localized. These findings provide impetus for considering the application of AuNP to enhance therapeutic efficacy during stereotactic radiosurgery for neovascular AMD.

  3. Computer-based radiological longitudinal evaluation of meningiomas following stereotactic radiosurgery.

    Science.gov (United States)

    Shimol, Eli Ben; Joskowicz, Leo; Eliahou, Ruth; Shoshan, Yigal

    2018-02-01

    Stereotactic radiosurgery (SRS) is a common treatment for intracranial meningiomas. SRS is planned on a pre-therapy gadolinium-enhanced T1-weighted MRI scan (Gd-T1w MRI) in which the meningioma contours have been delineated. Post-SRS therapy serial Gd-T1w MRI scans are then acquired for longitudinal treatment evaluation. Accurate tumor volume change quantification is required for treatment efficacy evaluation and for treatment continuation. We present a new algorithm for the automatic segmentation and volumetric assessment of meningioma in post-therapy Gd-T1w MRI scans. The inputs are the pre- and post-therapy Gd-T1w MRI scans and the meningioma delineation in the pre-therapy scan. The output is the meningioma delineations and volumes in the post-therapy scan. The algorithm uses the pre-therapy scan and its meningioma delineation to initialize an extended Chan-Vese active contour method and as a strong patient-specific intensity and shape prior for the post-therapy scan meningioma segmentation. The algorithm is automatic, obviates the need for independent tumor localization and segmentation initialization, and incorporates the same tumor delineation criteria in both the pre- and post-therapy scans. Our experimental results on retrospective pre- and post-therapy scans with a total of 32 meningiomas with volume ranges 0.4-26.5 cm[Formula: see text] yield a Dice coefficient of [Formula: see text]% with respect to ground-truth delineations in post-therapy scans created by two clinicians. These results indicate a high correspondence to the ground-truth delineations. Our algorithm yields more reliable and accurate tumor volume change measurements than other stand-alone segmentation methods. It may be a useful tool for quantitative meningioma prognosis evaluation after SRS.

  4. Optimization of dose distribution for the system of linear accelerator-based stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Suh Taesuk.

    1990-01-01

    This work addresses a method for obtaining an optimal dose distribution of stereotactic radiosurgery. Since stereotactic radiosurgery utilizes multiple noncoplanar arcs and a three-dimensional dose evaluation technique, many beam parameters and complex optimization criteria are included in the dose optimization. Consequently, a lengthy computation time is required to optimize even the simplest case by a trial and error method. The basic approach presented here is to use both an analytical and an experimental optimization to minimize the dose to critical organs while maintaining a dose shaped to the target. The experimental approach is based on shaping the target volumes using multiple isocenters from dose experience, or on field shaping using a beam's eye view technique. The analytical approach is to adapt computer-aided design optimization to find optimum parameters automatically. Three-dimensional approximate dose models are developed to simulate the exact dose model using a spherical or cylindrical coordinate system. Optimum parameters are found much faster with the use of computer-aided design optimization techniques. The implementation of computer-aided design algorithms with the approximate dose model and the application of the algorithms to several cases are discussed. It is shown that the approximate dose model gives dose distributions similar to those of the exact dose model, which makes the approximate dose model an attractive alternative to the exact dose model, and much more efficient in terms of computer-aided design and visual optimization

  5. Image-Guided Stereotactic Radiosurgery Using a Specially Designed High-Dose-Rate Linac

    International Nuclear Information System (INIS)

    Bayouth, John E.; Kaiser, Heather S.; Smith, Mark C.; Pennington, Edward C.; Anderson, Kathleen M. C.; Ryken, Timothy C.; Buatti, John M.

    2007-01-01

    Stereotactic radiosurgery and image-guided radiotherapy (IGRT) place enhanced demands on treatment delivery machines. In this study, we describe a high-dose-rate output accelerator as a part of our stereotactic IGRT delivery system. The linac is a Siemens Oncor without a flattening filter, and enables dose rates to reach 1000 monitor units (MUs) per minute. Even at this high-dose-rate, the linac dosimetry system remains robust; constancy, linearity, and beam energy remain within 1% for 3 to 1000 MU. Dose profiles for larger field sizes are not flat, but they are radially symmetric and, as such, able to be modeled by a treatment planning system. Target localization is performed via optical guidance utilizing a 3-dimensional (3D) ultrasound probe coupled to an array of 4 infrared light-emitting diodes. These diodes are identified by a fixed infrared camera system that determines diode position and, by extension, all objects imaged in the room coordinate system. This system provides sub-millimeter localization accuracy for cranial applications and better than 1.5 mm for extracranial applications. Because stereotactic IGRT can require significantly longer times for treatment delivery, the advantages of the high-dose-rate design and its direct impact on IGRT are discussed

  6. Fractionated stereotactically guided radiotherapy and radiosurgery in the treatment of functional and nonfunctional adenomas of the pituitary gland

    International Nuclear Information System (INIS)

    Milker-Zabel, Stefanie; Debus, Juergen; Thilmann, Christoph; Schlegel, Wolfgang; Wannenmacher, Michael

    2001-01-01

    Purpose: We evaluated survival rates and side effects after fractionated stereotactically guided radiotherapy (SCRT) and radiosurgery in patients with pituitary adenoma. Methods and Materials: Between 1989 and 1998, 68 patients were treated with FSRT (n=63) or radiosurgery (n=5) for pituitary adenomas. Twenty-six had functional and 42 had nonfunctional adenomas. Follow-up included CT/MRI, endocrinologic, and ophthalmologic examinations. Mean follow-up was 38.7 months. Seven patients received radiotherapy as primary treatment and 39 patients received it postoperatively for residual disease. Twenty-two patients were treated for recurrent disease after surgery. Mean total dose was 52.2 Gy for SCRT, and 15 Gy for radiosurgery. Results: Overall local tumor control was 93% (60/65 patients). Forty-three patients had stable disease based on CT/MRI, while 15 had a reduction of tumor volume. After FSRT, 26% with a functional adenoma had a complete remission and 19% had a reduction of hormonal overproduction after 34 months' mean. Two patients with STH-secreting adenomas had an endocrinologic recurrence, one with an ACTH-secreting adenoma radiologic recurrence, within 54 months. Reduction of visual acuity was seen in 4 patients and partial hypopituitarism in 3 patients. None of the patients developed brain radionecrosis or radiation-induced gliomas. Conclusion: Stereotactically guided radiotherapy is effective and safe in the treatment of pituitary adenomas to improve local control and reduce hormonal overproduction

  7. Evaluation of the uncertainties in the TLD radiosurgery postal dose system

    International Nuclear Information System (INIS)

    Campos, Luciana Tourinho; Leite, Sandro Passos; Almeida, Carlos Eduardo Veloso de; Magalhães, Luís Alexandre Gonçalves

    2017-01-01

    Radiosurgery is a single-fraction radiation therapy procedure for treating intracranial lesions using a stereotactic apparatus and multiple narrow beams delivered through noncoplanar isocentric arcs. The Radiological Science Laboratory (LCR/UERJ) operates a postal audit programme in SRT and SRS. The purpose of the programme is to verify the target localization accuracy and the dosimetric conditions of the TPS. The programme works in such a way those TLDs are sent to the centre where they are to be irradiated to a certain dose. The aim of the present work is estimate the uncertainties in the process of dose determination, using experimental data. (author)

  8. Evaluation of the uncertainties in the TLD radiosurgery postal dose system

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Luciana Tourinho; Leite, Sandro Passos; Almeida, Carlos Eduardo Veloso de; Magalhães, Luís Alexandre Gonçalves, E-mail: tc_luciana@yahoo.com.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Radiosurgery is a single-fraction radiation therapy procedure for treating intracranial lesions using a stereotactic apparatus and multiple narrow beams delivered through noncoplanar isocentric arcs. The Radiological Science Laboratory (LCR/UERJ) operates a postal audit programme in SRT and SRS. The purpose of the programme is to verify the target localization accuracy and the dosimetric conditions of the TPS. The programme works in such a way those TLDs are sent to the centre where they are to be irradiated to a certain dose. The aim of the present work is estimate the uncertainties in the process of dose determination, using experimental data. (author)

  9. Intractable trigeminal neuralgia: A single institution experience in 26 patients treated with stereotactic gamma knife radiosurgery

    International Nuclear Information System (INIS)

    Mark, Rufus J.; Duma, Christopher M.; Jacques, Dean B.; Kopyov, Oleg V.; Copcutt, Brian

    1996-01-01

    Purpose: In patients with trigeminal neuralgia, severe pain can persist, or recur despite aggressive medical management and open surgery. Recently, Gamma Knife radiosurgery has been used with promising results. We report on our series of 26 patients with intractable trigeminal neuralgia treated with stereotactic Gamma Knife radiosurgery. Materials and Methods: Between 1991 and 1995, 26 patients with intractable trigeminal neuralgia were treated at our institution using stereotactic Gamma Knife radiosurgery. Medical management had failed in all cases. In addition, 13 patients underwent a total of 20 open surgeries, with transient, or no pain relief. There were 19 females, and 7 males. Patient ages ranged from 37 to 87 years, with a median of 74 years. All patients were treated with a 201 source Cobalt-60 Gamma Knife unit. All patients underwent placement of the Leksell frame, followed by MRI scanning and computer treatment planning. The target in all patients was the fifth cranial nerve root entry zone into the brainstem. Twenty-five patients received between 64.3 to 70 Gy prescribed to Dmax in one shot. One patient received 120 Gy to Dmax in one shot. The 4 mm collimator was used in 22 cases, and the 8 mm in 4 cases. Follow-up ranged from 5 to 55 months, with a median of 19 months. Complete resolution (CR) of pain was scored when the patient reported being pain free off all medication. Partial resolution (PR) was scored when the patient reported > 50% pain reduction after Gamma Knife treatment. Results: At last follow-up, 84.6% ((22(26))) reported CR or PR of pain after Gamma Knife treatment. Forty-two percent ((11(26))) of patients reported CR, and 42%((11(26))) reported PR of pain. There was a dose response. In patients receiving < 70 Gy, 25% ((3(12))) reported CR, while 57% ((8(14))) of those receiving ≥ 70 Gy reported CR. Complications occurred in two (8%) patients. One patient developed transient numbness of the face after 70 Gy, and a second patient

  10. Stereotactic radiosurgery for brainstem metastases: Survival, tumor control, and patient outcomes

    International Nuclear Information System (INIS)

    Hussain, Aamir; Brown, Paul D.; Stafford, Scott L.; Pollock, Bruce E.

    2007-01-01

    Purpose: Patients with brainstem metastases have limited treatment options. In this study, we reviewed outcomes after stereotactic radiosurgery (SRS) in the management of patients with brainstem metastases. Methods and Materials: Records were reviewed of 22 consecutive patients presenting with brainstem metastases who underwent SRS. The most frequent primary malignancy was the lung (n = 11), followed by breast (n = 3) and kidney (n = 2). Three patients (14%) also underwent whole-brain radiation therapy (WBRT). The median tumor volume was 0.9 mL (range, 0.1-3.3 mL); the median tumor margin dose was 16 Gy (range, 14-23 Gy). Results: Median survival time after SRS was 8.5 months. Although local tumor control was achieved in all patients with imaging follow-up (n = 19), 5 patients died from development and progression of new brain metastases. Two patients (9%) had symptom improvement after SRS, whereas 1 patient (5%) developed a new hemiparesis after SRS. Conclusions: Radiosurgery is safe and provides a high local tumor control rate for patients with small brainstem metastases. Patients with limited systemic disease and good performance status should be strongly considered for SRS

  11. Geometrical and dosimetrical characterization of the photon source using a micro-multileaf collimator for stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Treuer, H; Hoevels, M; Luyken, K; Hunsche, S; Kocher, M; Mueller, R-P; Sturm, V

    2003-01-01

    A micro-multileaf collimator (μMLC) for stereotactic radiosurgery is used for determination of the spatial intensity distribution of the photon source of a linear accelerator. The method is based on grid field dose measurements using film dosimetry and is easy to perform. Since the μMLC does not allow 'direct' imaging of the photon source, special software has been developed to analyse grid field measurements. Besides the source-density function, grid field analysis yields the position of the focal spot in the room laser coordinate system of the linear accelerator and the position of the treatment head rotation axis and the inclination angle of the leaf bank. Thus the method can be used for base dosimetry and for quality assurance in radiosurgery using a μMLC

  12. Radiosurgical treatment planning for intracranial AVM based on images generated by principal component analysis. A simulation study

    International Nuclear Information System (INIS)

    Kawaguchi, Osamu; Kunieda, Etsuo; Nyui, Yoshiyuki

    2009-01-01

    One of the most important factors in stereotactic radiosurgery (SRS) for intracranial arteriovenous malformation (AVM) is to determine accurate target delineation of the nidus. However, since intracranial AVMs are complicated in structure, it is often difficult to clearly determine the target delineation. The purpose of this study was to investigate the usefulness of principal component analysis (PCA) on intra-arterial contrast enhanced dynamic CT (IADCT) images as a tool for delineating accurate target volumes for stereotactic radiosurgery of AVMs. IADCT and intravenous contrast-enhanced CT (IVCT) were used to examine 4 randomly selected cases of AVM. PCA images were generated from the IADCT data. The first component images were considered feeding artery predominant, the second component images were considered draining vein predominant, and the third component images were considered background. Target delineations were first carried out from IVCT, and then again while referring to the first and second components of the PCA images. Dose calculation simulations for radiosurgical treatment plans with IVCT and PCA images were performed. Dose volume histograms of the vein areas as well as the target volumes were compared. In all cases, the calculated target volumes based on IVCT images were larger than those based on PCA images, and the irradiation doses for the vein areas were reduced. In this study, we simulated radiosurgical treatment planning for intracranial AVM based on PCA images. By using PCA images, the irradiation doses for the vein areas were substantially reduced. (author)

  13. Silent Corticotroph Adenomas After Stereotactic Radiosurgery: A Case–Control Study

    International Nuclear Information System (INIS)

    Xu, Zhiyuan; Ellis, Scott; Lee, Cheng-Chia; Starke, Robert M.; Schlesinger, David; Lee Vance, Mary; Lopes, M. Beatriz; Sheehan, Jason

    2014-01-01

    Purpose: To investigate the safety and effectiveness of stereotactic radiosurgery (SRS) in patients with a silent corticotroph adenoma (SCA) compared with patients with other subtypes of non–adrenocorticotropic hormone staining nonfunctioning pituitary adenoma (NFA). Methods and Materials: The clinical features and outcomes of 104 NFA patients treated with SRS in our center between September 1994 and August 2012 were evaluated. Among them, 34 consecutive patients with a confirmatory SCA were identified. A control group of 70 patients with other subtypes of NFA were selected for review based on comparable baseline features, including sex, age at the time of SRS, tumor size, margin radiation dose to the tumor, and duration of follow-up. Results: The median follow-up after SRS was 56 months (range, 6-200 months). No patients with an SCA developed Cushing disease during the follow-up. Tumor control was achieved in 21 of 34 patients (62%) in the SCA group, compared with 65 of 70 patients (93%) in the NFA group. The median progression-free survival (PFS) was 58 months in the SCA group. The actuarial PFS was 73%, 46%, and 31% in the SCA group and was 94%, 87%, and 87% in the NFA group at 3, 5, and 8 years, respectively. Silent corticotroph adenomas treated with a dose of ≥17 Gy exhibited improved PFS. New-onset loss of pituitary function developed in 10 patients (29%) in the SCA group, whereas it occurred in 18 patients (26%) in the NFA group. Eight patients (24%) in the SCA group experienced worsening of a visual field deficit or visual acuity attributed to the tumor progression, as did 6 patients (9%) in the NFA group. Conclusion: Silent corticotroph adenomas exhibited a more aggressive course with a higher progression rate than other subtypes of NFAs. Stereotactic radiosurgery is an important adjuvant treatment for control of tumor growth. Increased radiation dose may lead to improved tumor control in SCA patients

  14. Silent Corticotroph Adenomas After Stereotactic Radiosurgery: A Case–Control Study

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhiyuan; Ellis, Scott; Lee, Cheng-Chia; Starke, Robert M. [Department of Neurological Surgery, University of Virginia, Charlottesville, Virginia (United States); Schlesinger, David [Department of Neurological Surgery, University of Virginia, Charlottesville, Virginia (United States); Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia (United States); Lee Vance, Mary [Department of Neurological Surgery, University of Virginia, Charlottesville, Virginia (United States); Department of Internal Medicine, University of Virginia, Charlottesville, Virginia (United States); Lopes, M. Beatriz [Division of Neuropathology, University of Virginia, Charlottesville, Virginia (United States); Sheehan, Jason, E-mail: jsheehan@virginia.edu [Department of Neurological Surgery, University of Virginia, Charlottesville, Virginia (United States); Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia (United States)

    2014-11-15

    Purpose: To investigate the safety and effectiveness of stereotactic radiosurgery (SRS) in patients with a silent corticotroph adenoma (SCA) compared with patients with other subtypes of non–adrenocorticotropic hormone staining nonfunctioning pituitary adenoma (NFA). Methods and Materials: The clinical features and outcomes of 104 NFA patients treated with SRS in our center between September 1994 and August 2012 were evaluated. Among them, 34 consecutive patients with a confirmatory SCA were identified. A control group of 70 patients with other subtypes of NFA were selected for review based on comparable baseline features, including sex, age at the time of SRS, tumor size, margin radiation dose to the tumor, and duration of follow-up. Results: The median follow-up after SRS was 56 months (range, 6-200 months). No patients with an SCA developed Cushing disease during the follow-up. Tumor control was achieved in 21 of 34 patients (62%) in the SCA group, compared with 65 of 70 patients (93%) in the NFA group. The median progression-free survival (PFS) was 58 months in the SCA group. The actuarial PFS was 73%, 46%, and 31% in the SCA group and was 94%, 87%, and 87% in the NFA group at 3, 5, and 8 years, respectively. Silent corticotroph adenomas treated with a dose of ≥17 Gy exhibited improved PFS. New-onset loss of pituitary function developed in 10 patients (29%) in the SCA group, whereas it occurred in 18 patients (26%) in the NFA group. Eight patients (24%) in the SCA group experienced worsening of a visual field deficit or visual acuity attributed to the tumor progression, as did 6 patients (9%) in the NFA group. Conclusion: Silent corticotroph adenomas exhibited a more aggressive course with a higher progression rate than other subtypes of NFAs. Stereotactic radiosurgery is an important adjuvant treatment for control of tumor growth. Increased radiation dose may lead to improved tumor control in SCA patients.

  15. Stereotactic radiosurgery for the treatment of meningiomas; Radiocirurgia estereotaxica no tratamento de meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Penna, Antonio Belmiro Rodrigues Campbell [Hospital dos Servidores do Estado, Rio de Janeiro, RJ (Brazil). Servico de Radioterapia; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Vieira, Sergio Lannes [Hospital Sao Vicente de Paula, Rio de Janeiro, RJ (Brazil). Servico de Radioterapia; Rossini Junior, Olamir [Clinica Radioterapia Botafogo Ltda., Rio de Janeiro, RJ (Brazil)

    2000-04-01

    We report the results of the treatment of four patients with inoperable meningiomas who underwent stereotactic radiosurgery using a linear accelerator of 6 MeV. Radiological examinations carried out from 12 to 22 months later revealed tumor growth arrest in all patients, giving a response rate of 100%. No early or late neurological complications dur to the radiosurgical treatment was observed. During the follow-up period no death caused by radiation was reported. Although the number of cases and the follow-up period were insufficient to show statistical significance, the results were satisfactory and thus require further investigations. (author)

  16. Geometrical and dosimetrical characterization of the photon source using a micro-multileaf collimator for stereotactic radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Treuer, H [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Hoevels, M [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Luyken, K [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Hunsche, S [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Kocher, M [Department of Radiotherapy, University of Cologne, Cologne (Germany); Mueller, R-P [Department of Radiotherapy, University of Cologne, Cologne (Germany); Sturm, V [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany)

    2003-08-07

    A micro-multileaf collimator ({mu}MLC) for stereotactic radiosurgery is used for determination of the spatial intensity distribution of the photon source of a linear accelerator. The method is based on grid field dose measurements using film dosimetry and is easy to perform. Since the {mu}MLC does not allow 'direct' imaging of the photon source, special software has been developed to analyse grid field measurements. Besides the source-density function, grid field analysis yields the position of the focal spot in the room laser coordinate system of the linear accelerator and the position of the treatment head rotation axis and the inclination angle of the leaf bank. Thus the method can be used for base dosimetry and for quality assurance in radiosurgery using a {mu}MLC.

  17. Concurrent Stereotactic Radiosurgery and Bevacizumab in Recurrent Malignant Gliomas: A Prospective Trial

    International Nuclear Information System (INIS)

    Cabrera, Alvin R.; Cuneo, Kyle C.; Desjardins, Annick; Sampson, John H.; McSherry, Frances; Herndon, James E.; Peters, Katherine B.; Allen, Karen; Hoang, Jenny K.; Chang, Zheng; Craciunescu, Oana; Vredenburgh, James J.; Friedman, Henry S.; Kirkpatrick, John P.

    2013-01-01

    Purpose: Virtually all patients with malignant glioma (MG) eventually recur. This study evaluates the safety of concurrent stereotactic radiosurgery (SRS) and bevacizumab (BVZ), an antiangiogenic agent, in treatment of recurrent MG. Methods and Materials: Fifteen patients with recurrent MG, treated at initial diagnosis with surgery and adjuvant radiation therapy/temozolomide and then at least 1 salvage chemotherapy regimen, were enrolled in this prospective trial. Lesions <3 cm in diameter were treated in a single fraction, whereas those 3 to 5 cm in diameter received 5 5-Gy fractions. BVZ was administered immediately before SRS and 2 weeks later. Neurocognitive testing (Mini-Mental Status Exam, Trail Making Test A/B), Functional Assessment of Cancer Therapy-Brain (FACT-Br) quality-of-life assessment, physical exam, and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) were performed immediately before SRS and 1 week and 2 months following completion of SRS. The primary endpoint was central nervous system (CNS) toxicity. Secondary endpoints included survival, quality of life, microvascular properties as measured by DCE-MRI, steroid usage, and performance status. Results: One grade 3 (severe headache) and 2 grade 2 CNS toxicities were observed. No patients experienced grade 4 to 5 toxicity or intracranial hemorrhage. Neurocognition, quality of life, and Karnofsky performance status did not change significantly with treatment. DCE-MRI results suggest a significant decline in tumor perfusion and permeability 1 week after SRS and further decline by 2 months. Conclusions: Treatment of recurrent MG with concurrent SRS and BVZ was not associated with excessive toxicity in this prospective trial. A randomized trial of concurrent SRS/BVZ versus conventional salvage therapy is needed to establish the efficacy of this approach

  18. Gamma Knife Radiosurgery for Acromegaly

    Directory of Open Access Journals (Sweden)

    John D. Rolston

    2012-01-01

    Full Text Available Acromegaly is debilitating disease occasionally refractory to surgical and medical treatment. Stereotactic radiosurgery, and in particular Gamma Knife surgery (GKS, has proven to be an effective noninvasive adjunct to traditional treatments, leading to disease remission in a substantial proportion of patients. Such remission holds the promise of eliminating the need for expensive medications, along with side effects, as well as sparing patients the damaging sequelae of uncontrolled acromegaly. Numerous studies of radiosurgical treatments for acromegaly have been carried out. These illustrate an overall remission rate over 40%. Morbidity from radiosurgery is infrequent but can include cranial nerve palsies and hypopituitarism. Overall, stereotactic radiosurgery is a promising therapy for patients with acromegaly and deserves further study to refine its role in the treatment of affected patients.

  19. Fractionated stereotactic radiation therapy and single high-dose radiosurgery for acoustic neuroma: early results of a prospective clinical study

    International Nuclear Information System (INIS)

    Meijer, O.W.M.; Wolbers, J.G.; Baayen, J.C.; Slotman, B.J.

    2000-01-01

    Purpose: To prospectively assess the local control and toxicity rate in acoustic neuroma patients treated with linear accelerator-based radiosurgery and fractionated stereotactic radiation therapy. Methods and Materials: We evaluated 37 consecutive patients treated with stereotactic radiation therapy for acoustic neuroma. All patients had progressive tumors, progressive symptoms, or both. Mean tumor diameter was 2.3 cm (range 0.8-3.3) on magnetic resonance (MR) scan. Dentate patients were given a dose of 5 x 4 Gy or 5 x 5 Gy and edentate patients were given a dose of 1 x 10 Gy or 1 x 12.50 Gy prescribed to the 80% isodose. All patients were treated with a single isocenter. Results: With a mean follow-up period of 25 months (range 12-61), the actuarial local control rate at 5 years was 91% (only 1 patient failed). The actuarial rate of hearing preservation at 5 years was 66% in previously-hearing patients. The actuarial rate of freedom from trigeminal nerve toxicity was 97% at 5 years. No patient developed facial nerve toxicity or other complications. Conclusion: In this unselected series, fractionated stereotactic radiation therapy and linear accelerator-based radiosurgery give excellent local control in acoustic neuroma. It combines a high rate of preservation of hearing with a very low rate of other toxicity, although follow-up is relatively short

  20. Postoperative Stereotactic Radiosurgery Without Whole-Brain Radiation Therapy for Brain Metastases: Potential Role of Preoperative Tumor Size

    International Nuclear Information System (INIS)

    Hartford, Alan C.; Paravati, Anthony J.; Spire, William J.; Li, Zhongze; Jarvis, Lesley A.; Fadul, Camilo E.; Rhodes, C. Harker; Erkmen, Kadir; Friedman, Jonathan; Gladstone, David J.; Hug, Eugen B.; Roberts, David W.; Simmons, Nathan E.

    2013-01-01

    Purpose: Radiation therapy following resection of a brain metastasis increases the probability of disease control at the surgical site. We analyzed our experience with postoperative stereotactic radiosurgery (SRS) as an alternative to whole-brain radiotherapy (WBRT), with an emphasis on identifying factors that might predict intracranial disease control and overall survival (OS). Methods and Materials: We retrospectively reviewed all patients through December 2008, who, after surgical resection, underwent SRS to the tumor bed, deferring WBRT. Multiple factors were analyzed for time to intracranial recurrence (ICR), whether local recurrence (LR) at the surgical bed or “distant” recurrence (DR) in the brain, for time to WBRT, and for OS. Results: A total of 49 lesions in 47 patients were treated with postoperative SRS. With median follow-up of 9.3 months (range, 1.1-61.4 months), local control rates at the resection cavity were 85.5% at 1 year and 66.9% at 2 years. OS rates at 1 and 2 years were 52.5% and 31.7%, respectively. On univariate analysis (preoperative) tumors larger than 3.0 cm exhibited a significantly shorter time to LR. At a cutoff of 2.0 cm, larger tumors resulted in significantly shorter times not only for LR but also for DR, ICR, and salvage WBRT. While multivariate Cox regressions showed preoperative size to be significant for times to DR, ICR, and WBRT, in similar multivariate analysis for OS, only the graded prognostic assessment proved to be significant. However, the number of intracranial metastases at presentation was not significantly associated with OS nor with other outcome variables. Conclusions: Larger tumor size was associated with shorter time to recurrence and with shorter time to salvage WBRT; however, larger tumors were not associated with decrements in OS, suggesting successful salvage. SRS to the tumor bed without WBRT is an effective treatment for resected brain metastases, achieving local control particularly for tumors up to

  1. Robotic radiosurgery. Treating tumors that move with respiration

    International Nuclear Information System (INIS)

    Urschel, Harold C. Jr.; Kresl, John J.; Luketich, James D.; Papiez, Lech; Timmerman, Robert D.; Schulz, Raymond A.

    2007-01-01

    Addresses in detail all aspects of the use of robotic radiosurgery to treat tumors of the lung, liver, and pancreas Includes full consideration of tumor tracking techniques, dosimetry, radiobiology, and fiducial placement strategies Written by leading experts Includes many high quality illustrations Stereotactic radiosurgery continues to evolve in ways that allow this powerful technology to reach and treat more tumors in more patients. This volume in the Robotic Radiosurgery series is devoted to theory and practice in the emerging field of stereotactic radiosurgery (also called stereotactic body radiation therapy) for extracranial tumors, particularly those that move as patients breathe. The book is divided into six sections. The first three sections address tumor motion due to respiration and tumor tracking techniques; dosimetry, radiobiology, and imaging; and fiducial placement systems. The fourth and fifth sections then discuss in depth the use of robotic radiosurgery to treat lung and abdominal tumors, respectively, and a final section explains emerging concepts and techniques. Within this framework, detailed information is provided on the technology and methodology for delivery of high doses of radiation to moving targets, radiobiological and radiological principles, and the challenges faced by clinicians performing extracranial stereotactic radiosurgery. Furthermore, there are thorough reviews of the general clinical literature on stereotactic radiation treatment of tumors of the lungs, liver, and pancreas, and the latest clinical data from clinicians conducting clinical studies using the CyberKnife registered Robotic Radiosurgery System. Special attention is given to the frameless robotic radiosurgery device known as the CyberKnife, the only image-guided radiosurgery system that utilizes intelligent robotics to track, detect, and correct for changes in tumor position during treatments. Tumors that move with respiration are treated with the CyberKnife using a

  2. Robotic radiosurgery. Treating tumors that move with respiration

    Energy Technology Data Exchange (ETDEWEB)

    Urschel, Harold C. Jr. [Baylor University Medical Center, Dallas, TX (United States). Chair of Cardiovascular and Thoracic Surgical Research, Education and Clinical Excellence; Kresl, John J. [Arizona Oncology Services at St. Joseph' s Hospital and Medical Center, Phoenix, AZ (United States). Dept. of Radiation Oncology; Luketich, James D. [University of Pittsburgh Medical Center PUH, Pittsburgh, PA (United States). The Heart, Lung and Esophageal Surgery Inst.; Papiez, Lech; Timmerman, Robert D. [University of Texas Southwestern Medical Center, Dallas, TX (United States). Dept. of Radiation Oncology; Schulz, Raymond A. (eds.)

    2007-07-01

    Addresses in detail all aspects of the use of robotic radiosurgery to treat tumors of the lung, liver, and pancreas Includes full consideration of tumor tracking techniques, dosimetry, radiobiology, and fiducial placement strategies Written by leading experts Includes many high quality illustrations Stereotactic radiosurgery continues to evolve in ways that allow this powerful technology to reach and treat more tumors in more patients. This volume in the Robotic Radiosurgery series is devoted to theory and practice in the emerging field of stereotactic radiosurgery (also called stereotactic body radiation therapy) for extracranial tumors, particularly those that move as patients breathe. The book is divided into six sections. The first three sections address tumor motion due to respiration and tumor tracking techniques; dosimetry, radiobiology, and imaging; and fiducial placement systems. The fourth and fifth sections then discuss in depth the use of robotic radiosurgery to treat lung and abdominal tumors, respectively, and a final section explains emerging concepts and techniques. Within this framework, detailed information is provided on the technology and methodology for delivery of high doses of radiation to moving targets, radiobiological and radiological principles, and the challenges faced by clinicians performing extracranial stereotactic radiosurgery. Furthermore, there are thorough reviews of the general clinical literature on stereotactic radiation treatment of tumors of the lungs, liver, and pancreas, and the latest clinical data from clinicians conducting clinical studies using the CyberKnife {sup registered} Robotic Radiosurgery System. Special attention is given to the frameless robotic radiosurgery device known as the CyberKnife, the only image-guided radiosurgery system that utilizes intelligent robotics to track, detect, and correct for changes in tumor position during treatments. Tumors that move with respiration are treated with the Cyber

  3. Poster - Thur Eve - 50: Planning and delivery accuracy of stereotactic radiosurgery with Tomotherapy as compared to linear-accelerator and robotic based radiosurgery.

    Science.gov (United States)

    Thakur, V; Soisson, E; Ruo, R; Doucet, R; Parker, W; Seuntjens, J

    2012-07-01

    This study includes planning and delivery comparison of three stereotactic radiosurgery techniques : Helical Tomotherapy (HT), circular collimator-based Linear-accelerator and robotic-radiosurgery. Plans were generated for two spherical targets of diameter 6 mm and 10 mm contoured at the center of a Lucite phantom, using similar planning constrains. Planning comparison showed that average conformality (0-1best) for Linear-accelerator, robotic-radiosurgery and HT was 1.43, 1.24, and 1.77 and gradient index (less is better) was 2.72, 4.50 and 13.56 respectively. For delivery comparison, plans were delivered to radiochromic film and measured dose was compared with the planned dose. For Linear-accelerator and robotic-radiosurgery more than 99% pixels-passing a gamma criteria of 3% dose difference and 1 mm distance to agreement where as for HT this value was as low as 40% for off-axis targets. Further investigation of the delivery accuracy as a function of the location of the target with in the bore was initiated using small volume A1SL (0.057 cm 3 ) and MicroLion liquid ion chamber (0.0017 cm 3 ). Point dose measurements for targets located at the center and 10 cm away from the center of the bore showed that delivered dose varied by more than 15% for targets placed away from the center of the bore as opposed to at the center. In conclusion, Linear-accelerator and the robotic-radiosurgery techniques showed preferable gradient and conformality. For HT, point dose measurements were significantly lower than predicted by the TPS when the target was positioned away from the isocenter, while they were found to be higher at isocenter. © 2012 American Association of Physicists in Medicine.

  4. A round-robin gamma stereotactic radiosurgery dosimetry interinstitution comparison of calibration protocols

    Energy Technology Data Exchange (ETDEWEB)

    Drzymala, R. E., E-mail: drzymala@wustl.edu [Department of Radiation Oncology, Washington University, St. Louis, Missouri 63110 (United States); Alvarez, P. E. [Imaging and Radiation Oncology Core Houston, UT MD Anderson Cancer Center, Houston, Texas 77030 (United States); Bednarz, G. [Radiation Oncology Department, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania 15232 (United States); Bourland, J. D. [Department of Radiation Oncology, Wake Forest University, Winston-Salem, North Carolina 27157 (United States); DeWerd, L. A. [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); Ma, L. [Department of Radiation Oncology, University California San Francisco, San Francisco, California 94143 (United States); Meltsner, S. G. [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Neyman, G. [Department of Radiation Oncology, The Cleveland Clinic Foundation, Cleveland, Ohio 44195 (United States); Novotny, J. [Medical Physics Department, Hospital Na Homolce, Prague 15030 (Czech Republic); Petti, P. L. [Gamma Knife Center, Washington Hospital Healthcare System, Fremont, California 94538 (United States); Rivard, M. J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Shiu, A. S. [Department of Radiation Oncology, University of Southern California, Los Angeles, California 90033 (United States); Goetsch, S. J. [San Diego Medical Physics, Inc., La Jolla, California 92037 (United States)

    2015-11-15

    Purpose: Absorbed dose calibration for gamma stereotactic radiosurgery is challenging due to the unique geometric conditions, dosimetry characteristics, and nonstandard field size of these devices. Members of the American Association of Physicists in Medicine (AAPM) Task Group 178 on Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance have participated in a round-robin exchange of calibrated measurement instrumentation and phantoms exploring two approved and two proposed calibration protocols or formalisms on ten gamma radiosurgery units. The objectives of this study were to benchmark and compare new formalisms to existing calibration methods, while maintaining traceability to U.S. primary dosimetry calibration laboratory standards. Methods: Nine institutions made measurements using ten gamma stereotactic radiosurgery units in three different 160 mm diameter spherical phantoms [acrylonitrile butadiene styrene (ABS) plastic, Solid Water, and liquid water] and in air using a positioning jig. Two calibrated miniature ionization chambers and one calibrated electrometer were circulated for all measurements. Reference dose-rates at the phantom center were determined using the well-established AAPM TG-21 or TG-51 dose calibration protocols and using two proposed dose calibration protocols/formalisms: an in-air protocol and a formalism proposed by the International Atomic Energy Agency (IAEA) working group for small and nonstandard radiation fields. Each institution’s results were normalized to the dose-rate determined at that institution using the TG-21 protocol in the ABS phantom. Results: Percentages of dose-rates within 1.5% of the reference dose-rate (TG-21 + ABS phantom) for the eight chamber-protocol-phantom combinations were the following: 88% for TG-21, 70% for TG-51, 93% for the new IAEA nonstandard-field formalism, and 65% for the new in-air protocol. Averages and standard deviations for dose-rates over all measurements relative to the TG-21 + ABS

  5. Early changes in volume and non-enhanced volume of acoustic neurinoma after stereotactic gamma-radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Hirofumi; Kobayashi, Tatsuya; Kida, Yoshihisa; Tanaka, Takayuki; Mori, Yoshimasa; Iwakoshi, Takayasu; Niwa, Masahiro; Kai, Osamu; Hirose, Mitsuhiko [Komaki City Hospital, Aichi (Japan)

    1994-09-01

    The effectiveness of stereotactic gamma-radiosurgery for treating acoustic neurinoma was evaluated by measuring the volumes of the tumor, non-enhanced tumor, and cerebellar edema in 13 patients with acoustic neurinoma who were followed up for 9 to 15 months (median 12.7 mos) after treatment. The tumor volume and non-enhanced volume tended to reach a maximum after 6 months, and cerebellar edema volume after 9 months, then decreased gradually thereafter. Hearing loss tended to increase gradually, but involvement of the facial nerve was transient. (author).

  6. Immediate side effects of stereotactic radiotherapy and radiosurgery

    International Nuclear Information System (INIS)

    Werner-Wasik, Maria; Rudoler, Shari; Preston, Peter E.; Downes, Beverly M.; Andrews, David; Corn, Benjamin W.; Rosenstock, Jeffrey; Curran, Walter J.

    1996-01-01

    Purpose/Objective: Despite increased utilization of fractionated stereotactic radiation therapy (SRT) or stereotactic radiosurgery (SRS), the incidence and nature of immediate side effects (ISE) associated with these treatment techniques is not well defined. Materials and Methods: Intracranial lesions in 78 adult patients were treated with SRT or SRS, using a dedicated linear accelerator. They comprised 13 gliomas, 2 ependymomas, 19 metastatic tumors, 15 meningiomas, 12 acoustic neuromas, 4 pituitary adenomas, 1 optic neuroma, 1 chondrosarcoma and 11 arteriovenous malformations (AVM). SRT was used in 51 and SRS in 27 patients. Mean target volume was 9.0 cc. Eleven patients received prior external beam radiation therapy within 2 months before SRT/SRS. Any side effects occurring during and up to two weeks after radiation course were defined as ISE and were graded as mild, moderate or severe. The incidence of ISE and the significance of their association with several pretreatment variables were analyzed. Results: Overall, (28(78)) (35%) patients experienced one or more ISE. Most of ISE (87%) were mild and consisted of nausea (5), dizziness/vertigo (5), seizures (7) and new persistent headaches (17). Two episodes of worsening neurological deficit and 2 of orbital pain were graded as moderate. Two patients experienced severe ISE, requiring hospitalization (1 seizure and 1 worsening neurological deficit). ISE in 5 cases prompted computerized tomography of the brain which revealed increased perilesional edema in 3 cases. The incidence of ISE by diagnosis was as follows: 46% ((6(13))) for gliomas, 50% ((6(12))) for acoustic neuromas, 36% ((4(11))) for AVM, 33% ((5(15))) for meningiomas and 21% ((4(19))) for metastases. Increasing dose to the margin and increasing maximum dose were associated with a higher incidence of ISE (p=0.02 and 0.005, respectively). Prior recent conventional external beam radiation therapy, target volume, number of isocenters, collimator size, dose

  7. Changing practice patterns of Gamma Knife versus linear accelerator-based stereotactic radiosurgery for brain metastases in the US.

    Science.gov (United States)

    Park, Henry S; Wang, Elyn H; Rutter, Charles E; Corso, Christopher D; Chiang, Veronica L; Yu, James B

    2016-04-01

    Single-fraction stereotactic radiosurgery (SRS) is a crucial component in the management of limited brain metastases from non-small cell lung cancer (NSCLC). Intracranial SRS has traditionally been delivered using a frame-based Gamma Knife (GK) platform, but stereotactic modifications to the linear accelerator (LINAC) have made an alternative approach possible. In the absence of definitive prospective trials comparing the efficacy and toxicities of treatment between the 2 techniques, nonclinical factors (such as technology accessibility, costs, and efficiency) may play a larger role in determining which radiosurgery system a facility may choose to install. To the authors' knowledge, this study is the first to investigate national patterns of GK SRS versus LINAC SRS use and to determine which factors may be associated with the adoption of these radiosurgery systems. The National Cancer Data Base was used to identify patients > 18 years old with NSCLC who were treated with single-fraction SRS to the brain between 2003 and 2011. Patients who received "SRS not otherwise specified" or who did not receive a radiotherapy dose within the range of 12-24 Gy were excluded to reduce the potential for misclassification. The chi-square test, t-test, and multivariable logistic regression analysis were used to compare potential demographic, clinicopathologic, and health care system predictors of GK versus LINAC SRS use, when appropriate. This study included 1780 patients, among whom 1371 (77.0%) received GK SRS and 409 (23.0%) underwent LINAC SRS. Over time, the proportion of patients undergoing LINAC SRS steadily increased, from 3.2% in 2003 to 30.8% in 2011 (p < 0.001). LINAC SRS was adopted more rapidly by community versus academic facilities (overall 29.2% vs 17.2%, p < 0.001). On multivariable analysis, 4 independent predictors of increased LINAC SRS use emerged, including year of diagnosis in 2008-2011 versus 2003-2007 (adjusted OR [AOR] 2.04, 95% CI 1.52-2.73, p < 0

  8. Clinical results of LINAC-based stereotactic radiosurgery for pituitary adenoma

    International Nuclear Information System (INIS)

    Muramatsu, Julia; Yoshida, Masanori; Shioura, Hiroki; Kawamura, Yasutaka; Ito, Harumi; Takeuchi, Hiroaki; Kubota, Toshihiko; Maruyama, Ichiro

    2003-01-01

    We retrospectively evaluated our clinical results of stereotactic radiosurgery (SRS) for pituitary adenoma. Between 1995 and 2000, 13 patients were treated with SRS for pituitary adenoma. In all cases, the tumors had already been surgically resected. The adenomas were functional in 5 and non-functional in 8 patients. The median follow-up period was 30 months. SRS was performed with the use of a dedicated stereotactic 10-MV linear accelerator (LINAC). The median dose to the tumor margin was 15 Gy. The dose to the optic apparatus was limited to less than 8 Gy. MR images of 12 patients revealed tumor complete response (CR) in one case and partial response (PR) in 9 cases; in the remaining two patients, tumor size decreased by less than 50%. There was no recognizable regrowth of any of the tumors. In two of four GH-secreting adenomas, hormonal overproduction normalized, while the other two showed reduced hormonal production. One PRL-secreting adenoma did not respond. Reduction of visual acuity and field was seen in one patient. This patient also had a brain infarction. None of the patients developed brain radionecrosis or radiation-induced hypopituitarism. Although further studies based on greater numbers of cases and longer follow-up periods are needed, our results suggest that SRS seems to be a safe, effective treatment for pituitary adenoma. (author)

  9. Impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans

    International Nuclear Information System (INIS)

    Kubo, H. Dale; Wilder, Richard B.; Pappas, Conrad T.E.

    1999-01-01

    Purpose: The authors undertook a study to analyze the impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans. Methods and Materials: Twelve cases involving primary brain tumors, metastases, or arteriovenous malformations that had been planned with BrainLAB's conventional circular collimator-based radiosurgery system were re-planned using a β-version of BrainLAB's treatment planning software that is compatible with MRC Systems' and BrainLAB's micro-multileaf collimators. These collimators have a minimum leaf width of 1.7 mm and 3.0 mm, respectively, at isocenter. The clinical target volumes ranged from 2.7-26.1 cc and the number of static fields ranged from 3-5. In addition, for 4 prostate cancer cases, 2 separate clinical target volumes were planned using MRC Systems' and BrainLAB's micro-multileaf collimators and Varian's multileaf collimator: the smaller clinical target volume consisted of the prostate gland and the larger clinical target volume consisted of the prostate and seminal vesicles. For the prostate cancer cases, treatment plans were generated using either 6 or 7 static fields. A 'PITV ratio', which the Radiation Therapy Oncology Group defines as the volume encompassed by the prescription isodose surface divided by the clinical target volume, was used as a measure of the quality of treatment plans (a PITV ratio of 1.0-2.0 is desirable). Bladder and rectal volumes encompassed by the prescription isodose surface, isodose distributions and dose volume histograms were also analyzed for the prostate cancer patients. Results: In 75% of the cases treated with radiosurgery, a PITV ratio between 1.0-2.0 could be achieved using a micro-multileaf collimator with a leaf width of 1.7-3.0 mm at isocenter and 3-5 static fields. When the clinical target volume consisted of the prostate gland, the micro-multileaf collimator with a minimum leaf width of 3.0 mm allowed one to decrease the median volume of bladder and

  10. Post-treatment neutrophil-to-lymphocyte ratio predicts for overall survival in brain metastases treated with stereotactic radiosurgery.

    Science.gov (United States)

    Chowdhary, Mudit; Switchenko, Jeffrey M; Press, Robert H; Jhaveri, Jaymin; Buchwald, Zachary S; Blumenfeld, Philip A; Marwaha, Gaurav; Diaz, Aidnag; Wang, Dian; Abrams, Ross A; Olson, Jeffrey J; Shu, Hui-Kuo G; Curran, Walter J; Patel, Kirtesh R

    2018-05-30

    Neutrophil-to-lymphocyte ratio (NLR) is a surrogate for systemic inflammatory response and its elevation has been shown to be a poor prognostic factor in various malignancies. Stereotactic radiosurgery (SRS) can induce a leukocyte-predominant inflammatory response. This study investigates the prognostic impact of post-SRS NLR in patients with brain metastases (BM). BM patients treated with SRS from 2003 to 2015 were retrospectively identified. NLR was calculated from the most recent full blood counts post-SRS. Overall survival (OS) and intracranial outcomes were calculated using the Kaplan-Meier method and cumulative incidence with competing risk for death, respectively. 188 patients with 328 BM treated with SRS had calculable post-treatment NLR values. Of these, 51 (27.1%) had a NLR > 6. The overall median imaging follow-up was 13.2 (14.0 vs. 8.7 for NLR ≤ 6.0 vs. > 6.0) months. Baseline patient and treatment characteristics were well balanced, except for lower rate of ECOG performance status 0 in the NLR > 6 cohort (33.3 vs. 44.2%, p = 0.026). NLR > 6 was associated with worse 1- and 2-year OS: 59.9 vs. 72.9% and 24.6 vs. 43.8%, (p = 0.028). On multivariable analysis, NLR > 6 (HR: 1.53; 95% CI 1.03-2.26, p = 0.036) and presence of extracranial metastases (HR: 1.90; 95% CI 1.30-2.78; p < 0.001) were significant predictors for worse OS. No association was seen with NLR and intracranial outcomes. Post-treatment NLR, a potential marker for post-SRS inflammatory response, is inversely associated with OS in patients with BM. If prospectively validated, NLR is a simple, systemic marker that can be easily used to guide subsequent management.

  11. Linear Accelerator Stereotactic Radiosurgery of Central Nervous System Arteriovenous Malformations: A 15-Year Analysis of Outcome-Related Factors in a Single Tertiary Center.

    Science.gov (United States)

    Thenier-Villa, José Luis; Galárraga-Campoverde, Raúl Alejandro; Martínez Rolán, Rosa María; De La Lama Zaragoza, Adolfo Ramón; Martínez Cueto, Pedro; Muñoz Garzón, Víctor; Salgado Fernández, Manuel; Conde Alonso, Cesáreo

    2017-07-01

    Linear accelerator stereotactic radiosurgery is one of the modalities available for the treatment of central nervous system arteriovenous malformations (AVMs). The aim of this study was to describe our 15-year experience with this technique in a single tertiary center and the analysis of outcome-related factors. From 1998 to 2013, 195 patients were treated with linear accelerator-based radiosurgery; we conducted a retrospective study collecting patient- and AVM-related variables. Treatment outcomes were obliteration, posttreatment hemorrhage, symptomatic radiation-induced changes, and 3-year neurologic status. We also analyzed prognostic factors of each outcome and predictability analysis of 5 scales: Spetzler-Martin grade, Lawton-Young supplementary and Lawton combined scores, radiosurgery-based AVM score, Virginia Radiosurgery AVM Scale, and Heidelberg score. Overall obliteration rate was 81%. Nidus diameter and venous drainage were predictive of obliteration (P linear accelerator-based radiosurgery is a useful, valid, effective, and safe modality for treatment of brain AVMs. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Dose variations caused by setup errors in intracranial stereotactic radiotherapy: A PRESAGE study

    International Nuclear Information System (INIS)

    Teng, Kieyin; Gagliardi, Frank; Alqathami, Mamdooh; Ackerly, Trevor; Geso, Moshi

    2014-01-01

    Stereotactic radiotherapy (SRT) requires tight margins around the tumor, thus producing a steep dose gradient between the tumor and the surrounding healthy tissue. Any setup errors might become clinically significant. To date, no study has been performed to evaluate the dosimetric variations caused by setup errors with a 3-dimensional dosimeter, the PRESAGE. This research aimed to evaluate the potential effect that setup errors have on the dose distribution of intracranial SRT. Computed tomography (CT) simulation of a CIRS radiosurgery head phantom was performed with 1.25-mm slice thickness. An ideal treatment plan was generated using Brainlab iPlan. A PRESAGE was made for every treatment with and without errors. A prescan using the optical CT scanner was carried out. Before treatment, the phantom was imaged using Brainlab ExacTrac. Actual radiotherapy treatments with and without errors were carried out with the Novalis treatment machine. Postscan was performed with an optical CT scanner to analyze the dose irradiation. The dose variation between treatments with and without errors was determined using a 3-dimensional gamma analysis. Errors are clinically insignificant when the passing ratio of the gamma analysis is 95% and above. Errors were clinically significant when the setup errors exceeded a 0.7-mm translation and a 0.5° rotation. The results showed that a 3-mm translation shift in the superior-inferior (SI), right-left (RL), and anterior-posterior (AP) directions and 2° couch rotation produced a passing ratio of 53.1%. Translational and rotational errors of 1.5 mm and 1°, respectively, generated a passing ratio of 62.2%. Translation shift of 0.7 mm in the directions of SI, RL, and AP and a 0.5° couch rotation produced a passing ratio of 96.2%. Preventing the occurrences of setup errors in intracranial SRT treatment is extremely important as errors greater than 0.7 mm and 0.5° alter the dose distribution. The geometrical displacements affect dose delivery

  13. Single-centre experience of stereotactic radiosurgery and fractionated stereotactic radiotherapy for prolactinomas with the linear accelerator.

    Science.gov (United States)

    Wilson, Peter J; Williams, Janet Rosemary; Smee, Robert Ian

    2015-06-01

    Primary management of prolactinomas is usually medical, with surgery a secondary option where necessary. This study is a review of a single centre's experience with focused radiotherapy where benefit was not gained by medical or surgical approaches. Radiotherapy as an alternative and adjuvant treatment for prolactinomas has been performed at our institution with the linear accelerator since 1990. We present a retrospective review of 13 patients managed with stereotactic radiosurgery (SRS) and 5 managed with fractionated stereotactic radiotherapy (FSRT), as well as 5 managed with conventional radiotherapy, at the Prince of Wales Hospital. Patients with a histopathologically diagnosed prolactinoma were eligible. Those patients who had a confirmed pathological diagnosis of prolactinoma following surgical intervention, a prolactin level elevated above 500 μg/L, or a prolactin level persistently elevated above 200 μg/L with exclusion of other causes were represented in this review. At the end of documented follow-up (SRS median 6 years, FSRT median 2 years), no SRS patients showed an increase in tumour volume. After FSRT, 1 patient showed an increase in size, 2 showed a decrease in size and 2 patients showed no change. Prolactin levels trended towards improvement after SRS and FSRT, but no patients achieved the remission level of <20 μg/L. Seven of 13 patients in the SRS group achieved a level of <500 μg/L, whereas no patients reached this target after FSRT. A reduction in prolactin level is frequent after SRS and FSRT for prolactinomas; however, true biochemical remission is uncommon. Tumour volume control in this series was excellent, but this may be related to the natural history of the disease. Morbidity and mortality after stereotactic radiation were very low in this series. © 2014 The Royal Australian and New Zealand College of Radiologists.

  14. Role of gamma knife radiosurgery in neurosurgery. Past and future perspectives

    International Nuclear Information System (INIS)

    Koga, Tomoyuki; Shin, Masahiro; Saito, Nobuhito

    2010-01-01

    The gamma knife was the first radiosurgical device developed at the Karolinska Institute in 1967. Stereotactic radiosurgery using the gamma knife has been widely accepted in clinical practice and has contributed to the development of neurosurgery. More than 500,000 patients have been treated by gamma knife stereotactic radiosurgery so far, and the method is now an indispensable neurosurgical tool. Here we review long-term outcomes and development of stereotactic radiosurgery using the gamma knife and discuss its future perspectives. The primary role of stereotactic radiosurgery is to control small well-demarcated lesions such as metastatic brain tumors, meningiomas, schwannomas, and pituitary adenomas while preserving the function of surrounding brain tissue. The gamma knife has been used as a primary treatment or in combination with surgery, and some applications have been accepted as standard treatment in the field of neurosurgery. Treatment of cerebral arteriovenous malformations has also been drastically changed after emergence of this technology. Controlling functional disorders is another role of stereotactic radiosurgery. There is a risk of radiation-induced adverse events, which are usually mild and less frequent. However, especially in large or invasive lesions, those risks are not negligible and pose limitations. Advancement of irradiation technology and dose planning software have enabled more sophisticated and safer treatment, and further progress will contribute to better treatment outcomes not only for brain lesions but also for cervical lesions with less invasive treatment. (author)

  15. Fractionated stereotactic radiation therapy for intracranial benign tumor : preliminary results of clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Yong; Ahn, Yong Chan; Huh, Seung Jae [Samsung Medical Center, Syungkyunkwan Univ. College of Medicine, Seoul (Korea, Republic of)] (and others)

    1998-06-01

    With the development of stereotactic immobilization systems capable of reliable serial repositioning, fractionated stereotactic radiation therapy(FSRT) offers the potential for an improved treatment outcome by excellent dose delivery, and dose distribution characteristics with the favorable radio-biological properties of fractionated irradiation. We describe our initial experience using FSRT for the treatment of intracranial benign tumor. Between August 1995 and December 1996, 15 patients(7 males and 8 females aged 6-70 years) were treated with FSRT. The patients had the following diagnosis : pituitary adenoma(10) including one patient who previously had received radiotherapy, craniopharyngioma(2), acoustic neurinoma(1), meningioma(2). Using the Gill-Thomas-Cos-man relocatable head frame and multiple non-coplanar therapy, the daily dose of 2Gy was irradiated at 90% to 100% isodose surface of the isocenter. The collimator sizes ranged from 26mm to 70mm. In all patients except one follow-up lost, disease was well-controlled. Acute complication was negligible and no patient experienced cranial nerve neuropathies and radiation necrosis. In overall patient setup with scalp measurements, reproducibility was found to have mean of 1.1{+-}0.6mm from the baseline reading. Relocatable stereotactic system for FSRT is highly reproducible and comfortable. Although the follow-up period was relatively short, FSRT is considered to be a safe an effective radiation technique as the treatment of intracranial tumor. But the fractionation schedule(fraction size, overall treatment time and total dose) still remains to be solved by further clinical trials.

  16. Evaluation of the uncertainties in the TLD radiosurgery postal dose system

    Science.gov (United States)

    Campos, L. T.; Leite, S. P.; de Almeida, C. E. V.; Magalhães, L. A. G.

    2018-03-01

    Stereotactic radiosurgery is a single-fraction radiation therapy procedure for treating intracranial lesions using a stereotactic apparatus and multiple narrow beams delivered through noncoplanar isocentric arcs. To guarantee a high quality standard, a comprehensive Quality Assurance programme is extremely important to ensure that the measured dose is consistent with the tolerance considered to improve treatment quality. The Radiological Science Laboratory operates a postal audit programme in SRT and SRS. The purpose of the programme is to verify the target localization accuracy in known geometry and the dosimetric conditions of the TPS. The programme works in such a way those thermoluminescence dosimeters, consisting of LiF chips, are sent to the centre where they are to be irradiated to a certain dose. The TLD are then returned, where they are evaluated and the absorbed dose is obtained from TLDs readings. The aim of the present work is estimate the uncertainties in the process of dose determination, using experimental data.

  17. Stereotactic Radiosurgery - Gamma Knife

    Science.gov (United States)

    ... DE, Adler JR Jr, Ewend MG. Image-guided robotic radiosurgery. In: Winn RH, ed. Youmans Neurological Surgery . ... by URAC, also known as the American Accreditation HealthCare Commission (www.urac.org). URAC's accreditation program is ...

  18. Role of Adjuvant Radiosurgery after Thoracoscopic Microsurgical Resection of a Spinal Schwannoma

    Directory of Open Access Journals (Sweden)

    Toba N. Niazi

    2012-01-01

    Full Text Available Stereotactic radiosurgery to benign tumors of the spine has not been advocated as a primary treatment modality because of the favorable prognosis for these lesions after gross-total resection. There is even less evidence regarding its use as an adjuvant to neurosurgical resection of benign recurrent spinal disease. We describe the case of a 30-year-old man with a thoracic spinal schwannoma who had an interval increase of his lesion five months after thoracoscopic microsurgical resection. The patient opted for noninvasive stereotactic radiosurgery in lieu of additional surgical excision and has had stable disease 15 months after radiosurgical treatment with the linear accelerator (LINAC system. In this setting, stereotactic radiosurgery provided a useful adjunct to thoracoscopic microsurgical resection. Future Class I and II evidence should be sought to evaluate the utility of stereotactic radiosurgery as a primary treatment modality or as an adjuvant for microneurosurgical resection of benign spinal lesions in patients who want noninvasive treatment after disease recurrence or who harbor medical comorbidities that would preclude them from being safe surgical candidates.

  19. Use of 3.0-T MRI for Stereotactic Radiosurgery Planning for Treatment of Brain Metastases: A Single-Institution Retrospective Review

    International Nuclear Information System (INIS)

    Saconn, Paul A.; Shaw, Edward G.; Chan, Michael D.; Squire, Sarah E.; Johnson, Annette J.; McMullen, Kevin P.; Tatter, Stephen B.; Ellis, Thomas L.; Lovato, James; Bourland, J. Daniel; Ekstrand, Kenneth E.; DeGuzman, Allan F.; Munley, Michael T.

    2010-01-01

    Purpose: To investigate the efficacy of 3.0-T magnetic resonance imaging (MRI) for detecting brain metastases for stereotactic radiosurgery (SRS) planning. Methods and Materials: All adult patients scheduled for SRS treatment for brain metastases at our institution between October 2005 and January 2008 were eligible for analysis. All patients underwent radiosurgery treatment planning 3.0-T MRI on the day of scheduled radiosurgery and a diagnostic 1.5-T MRI in the days or weeks prior to radiosurgery for comparison. Both scans were interpreted by neuroradiologists who reported their findings in the radiology reports. We performed a retrospective review of the radiology reports to determine the number of brain metastases identified using each MRI system. Results: Of 254 patients scheduled for treatment from October 2005 to January 2008, 138 patients had radiology reports that explicitly described the number of metastases identified on both scans. With a median interval of 17 days (range, 1-82) between scans, the number of metastases detected using 1.5-T MRI system ranged from 1 to 5 and from 1 to 8 using the 3.0 T-MRI system. Twenty-two percent of patients were found to have a greater number of metastases with the 3.0 T-MRI system. The difference in number of metastases detected between the two scans for the entire cohort ranged from 0 to 6. Neither histology (p = 0.52 by chi-sq test) nor time between scans (p = 0.62 by linear regression) were significantly associated with the difference in number of metastases between scans. Conclusions: The 3.0-T MRI system appears to be superior to a 1.5-T MRI system for detecting brain metastases, which may have significant implications in determining the appropriate treatment modality. Our findings suggest the need for a prospectively designed study to further evaluate the use of a 3.0 T-MRI system for stereotactic radiosurgery planning in the treatment of brain metastases.

  20. Development of a phantom for quality control of radiosurgery

    International Nuclear Information System (INIS)

    Scheidegger Soboll, D.; Reuters Schelin, H.

    2008-01-01

    The aim of this work was to build a phantom for quality control of stereotactic radiosurgery on linear accelerators. The outward appearance is a translucent human head filled with water and enclosing an insert with test objects of known shapes. The phantom was submitted to computerized tomography, magnetic resonance imaging and angiography exams, in order to perform a radiosurgery planning. Contours of the internal structures on the therapy planning system were drawn over the MRI images. Through the image fusion of CT and MRI, the contour data was transferred to CT images. Stereotactic registration of CT and angiography was made. One isocenter treatment was created, and using the stereotactic coordinates given by the therapy planning system, the phantom was placed on a linac. X-ray images were performed in order to verify the final positioning of the planned isocenter. In the whole process the phantom showed usefulness and adequacy for the positioning quality control of stereotactic radiosurgery with linacs, according to the main documents concerning the issue. (author)

  1. Extracranial doses during stereotactic radiosurgery and fractionated stereotactic radiotherapy measured with thermoluminescent dosimeter in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Kim, I.H.; Lim, D.H.; Kim, S.; Hong, S.; Kim, B.K.; Kang, W-S.; Wu, H.G.; Ha, S.W.; Park, C.I. [Seoul National University College of Medicine, Department of Therapeutic Radiology (Korea)

    2000-05-01

    Recently the usage of 3-dimensional non-coplanar radiotherapy technique is increasing. We measured the extracranial dose and its distribution g the above medical procedures to estimate effect of exit doses of stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (FSRT) of the intracranial target lesions using a linac system developed in our hospital. Among over hundred patients who were treated with SRS or FSRT from 1995 to 1998, radiation dosimetry data of 15 cases with SRS and 20 cases with FSRT were analyzed. All patients were adults. Of SRS cases, 11 were male and 4 were female. Vascular malformation cases were 9, benign tumors were 3, and malignant tumors were 3. Of FSRT cases, males were 12 and females were 8. Primary malignant brain tumors were 5, benign tumors were 6, and metastatic brain tumors were 10. Doses were measured with lithium fluoride TLD chips (7.5% Li-6 and 92.5% Li-7; TLD-100, Harshaw/Filtrol, USA). The chips were attached patient's skin at the various extracranial locations during SRS or FSRT. For SRS, 14-25 Gy were delivered with 1-2 isocenters using 12-38 mm circular tertiary collimators with reference to 50-80% isodose line conforming at the periphery of the target lesions. For FSRT, 5-28 fractions were used to deliver 9-56 Gy to periphery with dose maximum of 10-66 Gy. Both procedures used 6 MV X-ray generated from Clinac-18 (Varian, USA). For SRS procedures, extracranial surface doses (relative doses) were 8.07{+-}4.27 Gy (0.31{+-}0.16% Mean{+-}S.D.) at the upper eyelids, 6.13{+-}4.32 Gy (0.24{+-}0.16%) at the submental jaw, 7.80{+-}5.44 Gy (0.33{+-}0.26%) at thyroid, 1.78{+-}0.64 Gy (0.07{+-}0.02%) at breast, 0.75{+-}0.38 Gy (0.03{+-}0.02%) at umbilicus, 0.40{+-}0.07 Gy (0.02{+-}0.01%) at perineum, and 0.46{+-}0.39 Gy (0.02{+-}0.01%) at scrotum. Thus the farther the distance from the brain, the less the dose to the location. In overall the doses were less than 0.3% and thus less detrimental. For FSRT procedures

  2. Interactive stereotactic surgical system for the removal of intracranial tumors utilizing the CO2 laser and CT-derived database

    International Nuclear Information System (INIS)

    Kall, B.A.; Kelly, P.J.; Goerss, S.J.

    1985-01-01

    The transposition of data derived from computed tomography into three-dimensional stereotactic space has been found to be useful for the removal of intracranial tumors by a stereotactically directed CO 2 laser. Serial cross sections of a CT-derived tumor volume sliced orthogonal to any surgical trajectory are displayed in the operating room. Tumor slices are interactively vaporized with a stereotactically directed carbon dioxide laser. In this manner, the entire mass detected by CT scanning may be removed within a three-dimensionally controlled environment

  3. Stereotactic Radiosurgery for Classical Trigeminal Neuralgia

    Directory of Open Access Journals (Sweden)

    Henry Kodrat

    2016-04-01

    Full Text Available Trigeminal neuralgia is a debilitating pain syndrome with a distinct symptom mainly excruciating facial pain that tends to come and go unpredictably in sudden shock-like attacks. Medical management remains the primary treatment for classical trigeminal neuralgia. When medical therapy failed, surgery with microvascular decompression can be performed. Radiosurgery can be offered for classical trigeminal neuralgia patients who are not surgical candidate or surgery refusal and they should not in acute pain condition. Radiosurgery is widely used because of good therapeutic result and low complication rate. Weakness of this technique is a latency period, which is time required for pain relief. It usually ranges from 1 to 2 months. This review enlightens the important role of radiosurgery in the treatment of classical trigeminal neuralgia.

  4. Communicating Hydrocephalus Associated with Intracranial Schwannoma Treated by Gamma Knife Radiosurgery.

    Science.gov (United States)

    Park, Chang Kyu; Lee, Sung Ho; Choi, Man Kyu; Choi, Seok Keun; Park, Bong Jin; Lim, Young Jin

    2016-05-01

    Gamma knife radiosurgery (GKRS) has been established as an effective and safe treatment for intracranial schwannoma. However, serious complications can occur after GKRS, including hydrocephalus. The pathophysiology and risk factors of this disorder are not yet fully understood. The objective of the study was to assess potential risk factors for hydrocephalus after GKRS. We retrospectively reviewed the medical radiosurgical records of 244 patients who underwent GKRS to treat intracranial schwannoma. The following parameters were analyzed as potential risk factors for hydrocephalus after GKRS: age, sex, target volume, irradiation dose, prior tumor resection, treatment technique, and tumor enhancement pattern. The tumor enhancement pattern was divided into 2 groups: group A (homogeneous enhancement) and group B (heterogeneous or rim enhancement). Of the 244 patients, 14 of them (5.7%) developed communicating hydrocephalus. Communicating hydrocephalus occurred within 2 years after GKRS in most patients (92.8%). No significant association was observed between any of the parameters investigated and the development of hydrocephalus, with the exception of tumor enhancement pattern. Group B exhibited a statistically significant difference by univariate analysis (P = 0.002); this difference was also significant by multivariate analysis (P = 0.006). Because hydrocephalus is curable, patients should be closely monitored for the development of this disorder after GKRS. In particular, patients with intracranial schwannomas with irregular enhancement patterns or cysts should be meticulously observed. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. The rationale and technique of staged-volume arteriovenous malformation radiosurgery

    International Nuclear Information System (INIS)

    Pollock, Bruce E.; Kline, Robert W.; Stafford, Scott L.; Foote, Robert L.; Schomberg, Paula J.

    2000-01-01

    Purpose: Stereotactic radiosurgery is an effective management strategy for properly selected arteriovenous malformation (AVM) patients. However, the risk of postradiosurgical radiation-related injury generally limits this procedure to patients with AVMs of an average diameter of 3 cm or less. Radiosurgery of large AVMs in a planned staged fashion was undertaken to limit the radiation exposure to the surrounding normal brain. Methods and Materials: Between April 1997 and December 1999, 10 patients with a median AVM volume of 17.4 cm 3 (range, 7.4-53.3 cm 3 ) underwent staged-volume radiosurgery (23 procedures). At the first radiosurgical procedure, the total volume of the AVM is estimated and a dose plan calculated that covers 10 cm 3 -15 cm 3 , or one-half the nidus volume if the AVM is critically located (brainstem, thalamus, or basal ganglia). At 6-month intervals thereafter, radiosurgery was repeated to different portions of the AVM with the previous dose plan(s) being re-created utilizing intracranial landmarks to minimize radiation overlap. Radiosurgical procedures were continued until the entire malformation has been irradiated. Results: The radiation dosimetry of staged-volume AVM radiosurgery was compared to hypothetical single-session procedures for the 10 patients. Staged-volume radiosurgery decreased the 12-Gy volume by an average of 11.1% (range, 4.9-21%) (p < 0.001). The non-AVM 12-Gy volume was reduced by an average of 27.2% (range, 12.5-51.3%) (p < 0.001). Discussion: Staged-volume radiosurgery of large AVMs results in less radiation exposure to the adjacent brain. Further follow-up is needed to determine whether this technique provides a high rate of AVM obliteration while maintaining an acceptable rate of radiation-related complications

  6. Cyst formation after radiosurgery for brain arteriovenous malformation treated with cystoperitoneal shunt

    International Nuclear Information System (INIS)

    Morihiro, Yusuke; Kato, Syoichi; Imoto, Hirochika

    2010-01-01

    Gamma knife and CyberKnife radiosurgery are well established and less invasive treatments for arteriovenous malformation. Delayed cyst formation is a rare but well-known complication of radiosurgery for arteriovenous malformations. The optimal treatment of cysts forming after radiosurgery remains debatable. We present a case of cyst formation after radiosurgery for brain arteriovenous malformation that was treated with a cystoperitoneal shunt (C-P shunt). A 36-year-old woman presented with left hemiparesis and numbness. Computed tomography (CT) revealed intracranial hemorrhage in the right basal ganglia. Digital subtraction angiography revealed arteriovenous malformation in the brain. Intravascular embolization was performed three times and radiosurgery was performed twice, whereby complete obliteration of the nidus was achieved. Six and a half years later, routine follow-up magnetic resonance imaging revealed cyst formation, and the patient gradually developed left hemiparesis. First, we performed stereotactic cyst aspiration. This initially resulted in a reduction in the size of the cyst and disappearance of left hemiparesis, but within a short time, the cyst increased in size again and there was recurrence of hemiparesis. Therefore, an Ommaya reservoir was established; aspiration of the cyst through this reservoir brought about an initial reduction in cyst size and alleviation of symptoms; however, no further reduction in cyst size or improvement in symptoms could be achieved. Twenty months after the placement of the Ommaya reservoir, we performed a C-P shunt operation. After the operation, further reduction in the cyst size and complete symptomatic recovery were observed. (author)

  7. Stereotactic radiosurgery in acoustic neurinomas

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Masaaki; Noren, G. (Karolinska Hospital, Stockholm (Sweden))

    1990-12-01

    The records of 57 patients with 61 acoustic neurinomas treated with stereotatic radiosurgery at the Karolinska Hospital, Stockholm, from 1982 through 1984, were reviewed. Adequate radiological and clinical follow-up evaluations were available in these cases. An additional 8 patients were treated during this same period but were not included because of insufficient data. The tumors were evaluated with CT or MRI. Their post-operative follow-up period was 6-66 months (mean 28 months). Decrease of tumor size or no change was considered as a response to radiosurgery. This was found in 54 (88%) of the tumors. Small tumors with a diameter of less than 15 mm responded better (93%) than large ones (85%). Ninety-five percent of unilateral tumors and 74% of tumors associated with neurofibromatosis responded well. Seven tumors had definite radiographic signs of subsequent growth. Four were removed using standard microsurgical tequniques and three have so far not required further treatment. Facial and trigeminal nerve function was evaluated in 58 facial surfaces where tumors had been irradiated. Transient facial weakness developed in 9% and facial hypesthesia in 9% of the irradiated cases. The onset of these nerve dysfunction appeared with a latency period of 4 to 15 months after radiosurgery. Excluding the ears which had been totally deaf before the treatment, forty-one ears were evaluated fully by audiometry prior to and one year after irradiation. 30% of them had no change in hearing, 68% had a more or less pronouced deterioration and 2% had improvement. We regard efficiency in arresting tumor growth without endangering life, preservation of facial nerve function, and only a day of hospitalization as major benefits of radiosurgery. (author).

  8. Re-irradiation of recurrent anaplastic ependymoma using radiosurgery or fractionated stereotactic radiotherapy.

    Science.gov (United States)

    Murai, Taro; Sato, Kengo; Iwabuchi, Michio; Manabe, Yoshihiko; Ogino, Hiroyuki; Iwata, Hiromitsu; Tatewaki, Koshi; Yokota, Naoki; Ohta, Seiji; Shibamoto, Yuta

    2016-03-01

    Recurrent ependymomas were retreated with stereotactic radiosurgery (SRS) or fractionated stereotactic radiotherapy (FSRT). The efficacy, toxicities, and differences between SRS and FSRT were analyzed. Eight patients with recurrent ependymomas fulfilling the criteria described below were evaluated. Inclusion criteria were: (1) the patient had previously undergone surgery and conventional radiotherapy as first-line treatment; (2) targets were located in or adjacent to the eloquent area or were deep-seated; and (3) the previously irradiated volume overlapped the target lesion. FSRT was delivered to 18 lesions, SRS to 20 lesions. A median follow-up period was 23 months. The local control rate was 76 % at 3 years. No significant differences in local control were observed due to tumor size or fractionation schedule. Lesions receiving >25 Gy/5 fr or 21 Gy/3 fr did not recur within 1 year, whereas no dose-response relationship was observed in those treated with SRS. No grade ≥2 toxicity was observed. Our treatment protocol provided an acceptable LC rate and minimal toxicities. Because local recurrence of tumors may result in patient death, a minimum dose of 21 Gy/3 fr or 25 Gy/5 fr or higher may be most suitable for treatment of these cases.

  9. Surgical Resection of Brain Metastases and the Risk of Leptomeningeal Recurrence in Patients Treated With Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Johnson, Matthew D.; Avkshtol, Vladimir; Baschnagel, Andrew M.; Meyer, Kurt; Ye, Hong; Grills, Inga S.; Chen, Peter Y.; Maitz, Ann; Olson, Rick E.; Pieper, Daniel R.; Krauss, Daniel J.

    2016-01-01

    Purpose: Recent prospective data have shown that patients with solitary or oligometastatic disease to the brain may be treated with upfront stereotactic radiosurgery (SRS) with deferral of whole-brain radiation therapy (WBRT). This has been extrapolated to the treatment of patients with resected lesions. The aim of this study was to assess the risk of leptomeningeal disease (LMD) in patients treated with SRS to the postsurgical resection cavity for brain metastases compared with patients treated with SRS to intact metastases. Methods and Materials: Four hundred sixty-five patients treated with SRS without upfront WBRT at a single institution were identified; 330 of these with at least 3 months' follow-up were included in this analysis. One hundred twelve patients had undergone surgical resection of at least 1 lesion before SRS compared with 218 treated for intact metastases. Time to LMD and overall survival (OS) time were estimated from date of radiosurgery, and LMD was analyzed by the use of cumulative incidence method with death as a competing risk. Univariate and multivariate analyses were performed with competing risk regression to determine whether various clinical factors predicted for LMD. Results: With a median follow-up time of 9.0 months, 39 patients (12%) experienced LMD at a median of 6.0 months after SRS. At 1 year, the cumulative incidence of LMD, with death as a competing risk, was 5.2% for the patients without surgical resection versus 16.9% for those treated with surgery (Gray test, P<.01). On multivariate analysis, prior surgical resection (P<.01) and breast cancer primary (P=.03) were significant predictors of LMD development. The median OS times for patients undergoing surgery compared with SRS alone were 12.9 and 10.6 months, respectively (log-rank P=.06). Conclusions: In patients undergoing SRS with deferral of upfront WBRT for intracranial metastatic disease, prior surgical resection and breast cancer primary are associated with an

  10. Stereotactic radiosurgery for newly diagnosed brain metastases. Comparison of three dose levels

    International Nuclear Information System (INIS)

    Rades, Dirk; Hornung, Dagmar; Blanck, Oliver; Martens, Kristina; Khoa, Mai Trong; Trang, Ngo Thuy; Hueppe, Michael; Terheyden, Patrick; Gliemroth, Jan; Schild, Steven E.

    2014-01-01

    Three doses were compared for local control of irradiated metastases, freedom from new brain metastases, and survival in patients receiving stereotactic radiosurgery (SRS) alone for one to three newly diagnosed brain metastases. In all, 134 patients were assigned to three groups according to the SRS dose given to the margins of the lesions: 13-16 Gy (n = 33), 18 Gy (n = 18), and 20 Gy (n = 83). Additional potential prognostic factors were evaluated: age (≤ 60 vs. > 60 years), gender, Karnofsky Performance Scale score (70-80 vs. 90-100), tumor type (non-small-cell lung cancer vs. melanoma vs. others), number of brain metastases (1 vs. 2-3), lesion size ( 24 months). For 13-16 Gy, 18 Gy, and 20 Gy, the 1-year local control rates were 31, 65, and 79 %, respectively (p [de

  11. Radiosurgery by Leksell gamma knife

    International Nuclear Information System (INIS)

    Novotny, Josef

    2008-01-01

    The learning objectives of the lecture were as follows: to learn basic principles of Leksell gamma knife (LGK) radiosurgery; to discuss imaging, treatment planning and optimization procedures; to discuss quality assurance for LGK treatments; and to present examples of diagnoses treated by LGK. The following topics were discussed: Radiosurgery - definition, components of selectivity, fundamentals; Leksell gamma knife - principles; Stereotactic target localization; Radiosurgery - imaging; Treatment planning; LGK treatment; Quality control - process tree, LGK, distortion of scanners, 3D phantom measurements; Physical and technical parameters; and Clinical applications. (P.A.)

  12. SU-F-P-05: Initial Experience with an Independent Certification Program for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Solberg, T; Robar, J; Gevaert, T; Todorovic, M; Howe, J

    2016-01-01

    Purpose: The ASTRO document “Safety is no accident: A FRAMEWORK FOR QUALITY RADIATION ONCOLOGY AND CARE” recommends external reviews of specialized modalities. The purpose of this presentation is to describe the implementation of such a program for Stereotactic Radiosurgery (SRS) and Stereotactic Body radiation Therapy (SBRT). Methods: The margin of error for SRS and SBRT delivery is significantly smaller than that of conventional radiotherapy and therefore requires special attention and diligence. The Novalis Certified program was created to fill an unmet need for specialized SRS / SBRT credentialing. A standards document was drafted by a panel of experts from several disciplines, including medical physics, radiation oncology and neurosurgery. The document, based on national and international standards, covers requirements in program structure, personnel, training, clinical application, technology, quality management, and patient and equipment QA. The credentialing process was modeled after existing certification programs and includes an institution-generated self-study, extensive document review and an onsite audit. Reviewers generate a descriptive report, which is reviewed by a multidisciplinary expert panel. Outcomes of the review may include mandatory requirements and optional recommendations. Results: 15 institutions have received Novalis Certification, including 3 in the US, 7 in Europe, 4 in Australia and 1 in Asia. 87 other centers are at various stages of the process. Nine reviews have resulted in mandatory requirements, however all of these were addressed within three months of the audit report. All reviews have produced specific recommendations ranging from programmatic to technical in nature. Institutions felt that the credentialing process addressed a critical need and was highly valuable to the institution. Conclusion: Novalis Certification is a unique peer review program assessing safety and quality in SRS and SBRT, while recognizing

  13. SU-F-P-05: Initial Experience with an Independent Certification Program for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Solberg, T [University of Pennsylvania, Philadelphia, PA (United States); Robar, J [Capital District Health Authority, Halifax, NS (Canada); Gevaert, T [University Hospital Brussels, Brussels (Belgium); Todorovic, M [Universitats-Klinikum Hamburg-Eppendorf, Hamburg (Germany); Howe, J [Associates In Medical Physics, Louisville, KY (United States)

    2016-06-15

    Purpose: The ASTRO document “Safety is no accident: A FRAMEWORK FOR QUALITY RADIATION ONCOLOGY AND CARE” recommends external reviews of specialized modalities. The purpose of this presentation is to describe the implementation of such a program for Stereotactic Radiosurgery (SRS) and Stereotactic Body radiation Therapy (SBRT). Methods: The margin of error for SRS and SBRT delivery is significantly smaller than that of conventional radiotherapy and therefore requires special attention and diligence. The Novalis Certified program was created to fill an unmet need for specialized SRS / SBRT credentialing. A standards document was drafted by a panel of experts from several disciplines, including medical physics, radiation oncology and neurosurgery. The document, based on national and international standards, covers requirements in program structure, personnel, training, clinical application, technology, quality management, and patient and equipment QA. The credentialing process was modeled after existing certification programs and includes an institution-generated self-study, extensive document review and an onsite audit. Reviewers generate a descriptive report, which is reviewed by a multidisciplinary expert panel. Outcomes of the review may include mandatory requirements and optional recommendations. Results: 15 institutions have received Novalis Certification, including 3 in the US, 7 in Europe, 4 in Australia and 1 in Asia. 87 other centers are at various stages of the process. Nine reviews have resulted in mandatory requirements, however all of these were addressed within three months of the audit report. All reviews have produced specific recommendations ranging from programmatic to technical in nature. Institutions felt that the credentialing process addressed a critical need and was highly valuable to the institution. Conclusion: Novalis Certification is a unique peer review program assessing safety and quality in SRS and SBRT, while recognizing

  14. Radiosurgery for brain arteriovenous malformations

    International Nuclear Information System (INIS)

    Latorzeff, I.; Schlienger, M.; Sabatier, J.; Borius, P.Y.; Lotterie, J.A.; Bourdin, S.; Menegalli, D.; Cognard, C.; Januel, A.C.; Desal, H.; Debono, B.; Blond, S.

    2012-01-01

    Radiosurgery as treatment for arteriovenous malformations has shown a good efficacy in reducing intracranial bleeding due to rupture. The choice of therapeutic modalities is based on evolutive risk and arteriovenous malformations volume, patient profile and risks stratification following therapeutic techniques (microsurgery, radiosurgery, embolization). Nidus size, arteriovenous malformations anatomical localization, prior embolization or bleeding, distributed dose are predictive factors for radio-surgery's good results and tolerance. This review article will highlight arteriovenous malformations radiosurgery indications and discuss recent irradiation alternatives for large arteriovenous malformation volumes. (authors)

  15. Characteristics of a novel treatment system for linear accelerator-based stereotactic radiosurgery.

    Science.gov (United States)

    Wen, Ning; Li, Haisen; Song, Kwang; Chin-Snyder, Karen; Qin, Yujiao; Kim, Jinkoo; Bellon, Maria; Gulam, Misbah; Gardner, Stephen; Doemer, Anthony; Devpura, Suneetha; Gordon, James; Chetty, Indrin; Siddiqui, Farzan; Ajlouni, Munther; Pompa, Robert; Hammoud, Zane; Simoff, Michael; Kalkanis, Steven; Movsas, Benjamin; Siddiqui, M Salim

    2015-07-08

    The purpose of this study is to characterize the dosimetric properties and accuracy of a novel treatment platform (Edge radiosurgery system) for localizing and treating patients with frameless, image-guided stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT). Initial measurements of various components of the system, such as a comprehensive assessment of the dosimetric properties of the flattening filter-free (FFF) beams for both high definition (HD120) MLC and conical cone-based treatment, positioning accuracy and beam attenuation of a six degree of freedom (6DoF) couch, treatment head leakage test, and integrated end-to-end accuracy tests, have been performed. The end-to-end test of the system was performed by CT imaging a phantom and registering hidden targets on the treatment couch to determine the localization accuracy of the optical surface monitoring system (OSMS), cone-beam CT (CBCT), and MV imaging systems, as well as the radiation isocenter targeting accuracy. The deviations between the percent depth-dose curves acquired on the new linac-based system (Edge), and the previously published machine with FFF beams (TrueBeam) beyond D(max) were within 1.0% for both energies. The maximum deviation of output factors between the Edge and TrueBeam was 1.6%. The optimized dosimetric leaf gap values, which were fitted using Eclipse dose calculations and measurements based on representative spine radiosurgery plans, were 0.700 mm and 1.000 mm, respectively. For the conical cones, 6X FFF has sharper penumbra ranging from 1.2-1.8 mm (80%-20%) and 1.9-3.8 mm (90%-10%) relative to 10X FFF, which has 1.2-2.2mm and 2.3-5.1mm, respectively. The relative attenuation measurements of the couch for PA, PA (rails-in), oblique, oblique (rails-out), oblique (rails-in) were: -2.0%, -2.5%, -15.6%, -2.5%, -5.0% for 6X FFF and -1.4%, -1.5%, -12.2%, -2.5%, -5.0% for 10X FFF, respectively, with a slight decrease in attenuation versus field size. The systematic

  16. SU-E-J-25: End-To-End (E2E) Testing On TomoHDA System Using a Real Pig Head for Intracranial Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Corradini, N; Leick, M; Bonetti, M; Negretti, L [Clinica Luganese, Radiotherapy Center, Lugano (Switzerland)

    2015-06-15

    Purpose: To determine the MVCT imaging uncertainty on the TomoHDA system for intracranial radiosurgery treatments. To determine the end-to-end (E2E) overall accuracy of the TomoHDA system for intracranial radiosurgery. Methods: A pig head was obtained from the butcher, cut coronally through the brain, and preserved in formaldehyde. The base of the head was fixed to a positioning plate allowing precise movement, i.e. translation and rotation, in all 6 axes. A repeatability test was performed on the pig head to determine uncertainty in the image bone registration algorithm. Furthermore, the test studied images with MVCT slice thicknesses of 1 and 3 mm in unison with differing scan lengths. A sensitivity test was performed to determine the registration algorithm’s ability to find the absolute position of known translations/rotations of the pig head. The algorithm’s ability to determine absolute position was compared against that of manual operators, i.e. a radiation therapist and radiation oncologist. Finally, E2E tests for intracranial radiosurgery were performed by measuring the delivered dose distributions within the pig head using Gafchromic films. Results: The repeatability test uncertainty was lowest for the MVCTs of 1-mm slice thickness, which measured less than 0.10 mm and 0.12 deg for all axes. For the sensitivity tests, the bone registration algorithm performed better than human eyes and a maximum difference of 0.3 mm and 0.4 deg was observed for the axes. E2E test results in absolute position difference measured 0.03 ± 0.21 mm in x-axis and 0.28 ± 0.18 mm in y-axis. A maximum difference of 0.32 and 0.66 mm was observed in x and y, respectively. The average peak dose difference between measured and calculated dose was 2.7 cGy or 0.4%. Conclusion: Our tests using a pig head phantom estimate the TomoHDA system to have a submillimeter overall accuracy for intracranial radiosurgery.

  17. SU-E-J-25: End-To-End (E2E) Testing On TomoHDA System Using a Real Pig Head for Intracranial Radiosurgery

    International Nuclear Information System (INIS)

    Corradini, N; Leick, M; Bonetti, M; Negretti, L

    2015-01-01

    Purpose: To determine the MVCT imaging uncertainty on the TomoHDA system for intracranial radiosurgery treatments. To determine the end-to-end (E2E) overall accuracy of the TomoHDA system for intracranial radiosurgery. Methods: A pig head was obtained from the butcher, cut coronally through the brain, and preserved in formaldehyde. The base of the head was fixed to a positioning plate allowing precise movement, i.e. translation and rotation, in all 6 axes. A repeatability test was performed on the pig head to determine uncertainty in the image bone registration algorithm. Furthermore, the test studied images with MVCT slice thicknesses of 1 and 3 mm in unison with differing scan lengths. A sensitivity test was performed to determine the registration algorithm’s ability to find the absolute position of known translations/rotations of the pig head. The algorithm’s ability to determine absolute position was compared against that of manual operators, i.e. a radiation therapist and radiation oncologist. Finally, E2E tests for intracranial radiosurgery were performed by measuring the delivered dose distributions within the pig head using Gafchromic films. Results: The repeatability test uncertainty was lowest for the MVCTs of 1-mm slice thickness, which measured less than 0.10 mm and 0.12 deg for all axes. For the sensitivity tests, the bone registration algorithm performed better than human eyes and a maximum difference of 0.3 mm and 0.4 deg was observed for the axes. E2E test results in absolute position difference measured 0.03 ± 0.21 mm in x-axis and 0.28 ± 0.18 mm in y-axis. A maximum difference of 0.32 and 0.66 mm was observed in x and y, respectively. The average peak dose difference between measured and calculated dose was 2.7 cGy or 0.4%. Conclusion: Our tests using a pig head phantom estimate the TomoHDA system to have a submillimeter overall accuracy for intracranial radiosurgery

  18. Cone beam computed tomography image guidance system for a dedicated intracranial radiosurgery treatment unit.

    Science.gov (United States)

    Ruschin, Mark; Komljenovic, Philip T; Ansell, Steve; Ménard, Cynthia; Bootsma, Gregory; Cho, Young-Bin; Chung, Caroline; Jaffray, David

    2013-01-01

    Image guidance has improved the precision of fractionated radiation treatment delivery on linear accelerators. Precise radiation delivery is particularly critical when high doses are delivered to complex shapes with steep dose gradients near critical structures, as is the case for intracranial radiosurgery. To reduce potential geometric uncertainties, a cone beam computed tomography (CT) image guidance system was developed in-house to generate high-resolution images of the head at the time of treatment, using a dedicated radiosurgery unit. The performance and initial clinical use of this imaging system are described. A kilovoltage cone beam CT system was integrated with a Leksell Gamma Knife Perfexion radiosurgery unit. The X-ray tube and flat-panel detector are mounted on a translational arm, which is parked above the treatment unit when not in use. Upon descent, a rotational axis provides 210° of rotation for cone beam CT scans. Mechanical integrity of the system was evaluated over a 6-month period. Subsequent clinical commissioning included end-to-end testing of targeting performance and subjective image quality performance in phantoms. The system has been used to image 2 patients, 1 of whom received single-fraction radiosurgery and 1 who received 3 fractions, using a relocatable head frame. Images of phantoms demonstrated soft tissue contrast visibility and submillimeter spatial resolution. A contrast difference of 35 HU was easily detected at a calibration dose of 1.2 cGy (center of head phantom). The shape of the mechanical flex vs scan angle was highly reproducible and exhibited cone beam CT image guidance system was successfully adapted to a radiosurgery unit. The system is capable of producing high-resolution images of bone and soft tissue. The system is in clinical use and provides excellent image guidance without invasive frames. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. [Transient enlargement of craniopharyngioma cysts after stereotactic radiotherapy and radiosurgery].

    Science.gov (United States)

    Mazerkina, N A; Savateev, A N; Gorelyshev, S K; Konovalov, A N; Trunin, Yu Yu; Golanov, A V; Medvedeva, O A; Kalinin, P L; Kutin, M A; Astafieva, L I; Krasnova, T S; Ozerova, V I; Serova, N K; Butenko, E I; Strunina, Yu V

    Stereotactic radiotherapy/radiosurgery (RT/ES) is an effective technique for treating craniopharyngiomas (CPs). However, enlargement of the cystic part of the tumor occurs in some cases after irradiation. The enlargement may be transient and not require treatment or be a true relapse requiring treatment. In this study, we performed a retrospective analysis of 79 pediatric patients who underwent stereotactic RT or RS after resection of craniopharyngioma. Five-year relapse-free survival after complex treatment of CP was 86%. In the early period after irradiation, 3.5 months (2.7-9.4) on average, enlargement of the cystic component of the tumor was detected in 10 (12.7%) patients; in 9 (11.4%) of them, the enlargement was transient and did not require treatment; in one case, the patient underwent surgery due to reduced visual acuity. In 8 (10.1%) patients, an increase in the residual tumor (a solid component of the tumor in 2 cases and a cystic component of the tumor in 6 cases) occurred in the long-term period after irradiation - after 26.3 months (16.6-48.9) and did not decrease during follow-up in none of the cases, i.e. continued growth of the tumor was diagnosed. A statistical analysis revealed that differences in the terms of transient enlargement and true continued growth were statistically significant (pcraniopharyngioma cyst in the early period (up to 1 year) after RT/RS is usually transient and does not require surgical treatment (except cases where worsening of neurological symptoms occurs, or occlusive hydrocephalus develops).

  20. Radiosurgery and the double logistic product formula

    International Nuclear Information System (INIS)

    Flickinger, J.C.; Steiner, L.

    1990-01-01

    The double logistic product formula is proposed as a method for predicting the probability of developing brain necrosis after high dose irradiation of small target volumes as used in stereotactic radiosurgery. Dose-response data observed for the production of localized radiation necreosis for treating intractable pain with the original Leksell gamma unit were used to choose the best fitting parameters for the double logistic product formula. This model can be used with either exponential or linear quadratic formulas to account for the effects of dose, fractionation and time in addition to volume. Dose-response predictions for stereotactic radiosurgery with different sized collimators are presented. (author). 41 refs.; 5 figs.; 1 tab

  1. Stereotactic radiosurgery for spinal metastases: a literature review

    International Nuclear Information System (INIS)

    Joaquim, Andrei Fernandes; Ghizoni, Enrico; Tedeschi, Helder; Pereira, Eduardo Baldon; Giacomini, Leonardo Abdala

    2013-01-01

    Objective: The spine is the most common location for bone metastases. Since cure is not possible, local control and relief of symptoms is the basis for treatment, which is grounded on the use of conventional radiotherapy. Recently, spinal radiosurgery has been proposed for the local control of spinal metastases, whether as primary or salvage treatment. Consequently, we carried out a literature review in order to analyze the indications, efficacy, and safety of radiosurgery in the treatment of spinal metastases. Methods: We have reviewed the literature using the PubMed gateway with data from the Medline library on studies related to the use of radiosurgery in treatment of bone metastases in spine. The studies were reviewed by all the authors and classified as to level of evidence, using the criterion defined by Wright. Results: The indications found for radiosurgery were primary control of epidural metastases (evidence level II), myeloma (level III), and metastases known to be poor responders to conventional radiotherapy – melanoma and renal cell carcinoma (level III). Spinal radiosurgery was also proposed for salvage treatment after conventional radiotherapy (level II). There is also some evidence as to the safety and efficacy of radiosurgery in cases of extramedullar and intramedullar intradural metastatic tumors (level III) and after spinal decompression and stabilization surgery. Conclusion: Radiosurgery can be used in primary or salvage treatment of spinal metastases, improving local disease control and patient symptoms. It should also be considered as initial treatment for radioresistant tumors, such as melanoma and renal cell carcinoma. (author)

  2. Immediate side effects of stereotactic radiotherapy and radiosurgery

    International Nuclear Information System (INIS)

    Werner-Wasik, Maria; Rudoler, Shari; Preston, Peter E.; Hauck, Walter W.; Downes, Beverly M.; Leeper, Dennis; Andrews, David; Corn, Benjamin W.; Curran, Walter J.

    1999-01-01

    Purpose: Despite increased utilization of fractionated stereotactic radiation therapy (SRT) or stereotactic radiosurgery (SRS), the incidence and nature of immediate side effects (ISE) associated with these treatment techniques are not well defined. We report immediate side effects from a series of 78 patients. Materials and Methods: Intracranial lesions in 78 adult patients were treated with SRT or SRS, using a dedicated linear accelerator. Those lesions included 13 gliomas, 2 ependymomas, 19 metastatic tumors, 15 meningiomas, 12 acoustic neuromas, 4 pituitary adenomas, 1 optic neuroma, 1 chondrosarcoma, and 11 arteriovenous malformations (AVM). SRT was used in 51 and SRS in 27 patients. Mean target volume was 9.0 cc. Eleven patients received prior external-beam radiation therapy within 2 months before SRT/SRS. Any side effects occurring during and up to 2 weeks after the course of radiation were defined as ISE and were graded as mild, moderate, or severe. The incidence of ISE and the significance of their association with several treatment and pretreatment variables were analyzed. Results: Overall, 28 (35%) of 78 patients experienced one or more ISE. Most of the ISE (87%) were mild, and consisted of nausea (in 5), dizziness/vertigo (in 5), seizures (in 6), and new persistent headaches (in 17). Two episodes of worsening neurological deficit and 2 of orbital pain were graded as moderate. Two patients experienced severe ISE, requiring hospitalization (1 seizure and 1 worsening neurological deficit). ISE in 6 cases prompted computerized tomography of the brain, which revealed increased perilesional edema in 3 cases. The incidence of ISE by diagnosis was as follows: 46% (6 of 13) for gliomas, 50% (6 of 12) for acoustic neuromas, 36% (4 of 11) for AVM, 33% (5 of 15) for meningiomas, and 21% (4 of 19) for metastases. A higher incidence of dizziness/vertigo (4 of 12 = 33%) was seen among acoustic neuroma patients than among other patients (p < 0.01). There was no

  3. Stereotactic Radiation Therapy for Benign Meningioma: Long-Term Outcome in 318 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Fokas, Emmanouil, E-mail: emmanouil.fokas@kgu.de [Department of Radiotherapy and Radiation Oncology, Philipps-University Marburg, Marburg (Germany); Department of Radiation Therapy and Oncology, Johann Wolfgang Goethe University, Frankfurt (Germany); Henzel, Martin [Department of Radiotherapy and Radiation Oncology, Philipps-University Marburg, Marburg (Germany); Surber, Gunar; Hamm, Klaus [Department for Stereotactic Neurosurgery and Radiosurgery, HELIOS Klinikum Erfurt, Erfurt (Germany); Engenhart-Cabillic, Rita [Department of Radiotherapy and Radiation Oncology, Philipps-University Marburg, Marburg (Germany)

    2014-07-01

    Purpose: To investigate the long-term outcome of stereotactic-based radiation therapy in a large cohort of patients with benign intracranial meningiomas. Methods and Materials: Between 1997 and 2010, 318 patients with histologically confirmed (44.7%; previous surgery) or imaging-defined (55.3%) benign meningiomas were treated with either fractionated stereotactic radiation therapy (79.6%), hypofractionated stereotactic radiation therapy (15.4%), or stereotactic radiosurgery (5.0%), depending on tumor size and location. Local control (LC), overall survival (OS), cause-specific survival (CSS), prognostic factors, and toxicity were analyzed. Results: The median follow-up was 50 months (range, 12-167 months). Local control, OS, and CSS at 5 years were 92.9%, 88.7%, and 97.2%, and at 10 years they were 87.5%, 74.1%, and 97.2%, respectively. In the multivariate analysis, tumor location (P=.029) and age >66 years (P=.031) were predictors of LC and OS, respectively. Worsening of pre-existing neurologic symptoms immediately after radiation therapy occurred in up to 2%. Clinically significant acute toxicity (grade 3°) occurred in 3%. Only grade 1-2 late toxicity was observed in 12%, whereas no new neurologic deficits or treatment-related mortality were encountered. Conclusions: Patients with benign meningiomas predominantly treated with standard fractionated stereotactic radiation therapy with narrow margins enjoy excellent LC and CSS, with minimal long-term morbidity.

  4. Stereotactic Radiosurgery for Poor Performance Status Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kubicek, Gregory J., E-mail: kubicek-gregory@cooperhealth.edu [Department of Radiation Oncology, Cooper University Hospital, Camden, New Jersey (United States); Turtz, Alan [Department of Neurological Surgery, Cooper University Hospital, Camden, New Jersey (United States); Xue, Jinyu; Patel, Ashish; Richards, Gregory; LaCouture, Tamara [Department of Radiation Oncology, Cooper University Hospital, Camden, New Jersey (United States); Cappelli, Louis; Diestelkamp, Tim [Rowan Graduate School, Camden, New Jersey (United States); Saraiya, Piya [Department of Diagnostic Radiology, Cooper University Hospital, Camden, New Jersey (United States); Bexon, Anne [Department of Neurological Surgery, Cooper University Hospital, Camden, New Jersey (United States); Lerman, Nati [Department of Medical Oncology, Cooper University Hospital, Camden, New Jersey (United States); Goldman, Howard Warren [Department of Neurological Surgery, Cooper University Hospital, Camden, New Jersey (United States)

    2016-07-01

    Purpose: Patients with poor performance status (PS), usually defined as a Karnofsky Performance Status of 60 or less, were not eligible for randomized stereotactic radiosurgery (SRS) studies, and many guidelines suggest that whole-brain radiation therapy (WBRT) is the most appropriate treatment for poor PS patients. Methods and Materials: In this retrospective review of our SRS database, we identified 36 patients with PS of 60 or less treated with SRS for central nervous system (CNS) metastatic disease. PS, as defined by the Karnofsky Performance Status, was 60 (27 patients), 50 (8 patients), or 40 (1 patient). The median number of CNS lesions treated was 3. Results: Median overall survival (OS) was 7.2 months (range, 0.73-25.6 months). Fifteen patients (41%) were alive at 6 months, and 6 patients (16.6%) were alive at 1 year. There was no difference in OS in patients who underwent previous WBRT. There were no local failures or cases of radiation toxicity. Distant CNS failures were seen in 9 patients (25%). Conclusions: Our patients with poor PS had reasonable median OS and relatively low distant CNS failure rates. Patients in this patient population may be ideal candidates for SRS compared with WBRT given the low incidence of distant failure over their remaining lives and the favorable logistics of single-fraction treatment for these patients with debility and their caregivers.

  5. Intracranial stereotactic radiosurgery with an adapted linear accelerator vs. robotic radiosurgery. Comparison of dosimetric treatment plan quality

    Energy Technology Data Exchange (ETDEWEB)

    Treuer, Harald; Hoevels, Moritz; Luyken, Klaus; Visser-Vandewalle, Veerle; Wirths, Jochen; Ruge, Maximilian [University Hospital Cologne, Department of Stereotaxy and Functional Neurosurgery, Cologne (Germany); Kocher, Martin [University Hospital Cologne, Department of Radiotherapy, Cologne (Germany)

    2014-11-22

    Stereotactic radiosurgery with an adapted linear accelerator (linac-SRS) is an established therapy option for brain metastases, benign brain tumors, and arteriovenous malformations. We intended to investigate whether the dosimetric quality of treatment plans achieved with a CyberKnife (CK) is at least equivalent to that for linac-SRS with circular or micromultileaf collimators (microMLC). A random sample of 16 patients with 23 target volumes, previously treated with linac-SRS, was replanned with CK. Planning constraints were identical dose prescription and clinical applicability. In all cases uniform optimization scripts and inverse planning objectives were used. Plans were compared with respect to coverage, minimal dose within target volume, conformity index, and volume of brain tissue irradiated with ≥ 10 Gy. Generating the CK plan was unproblematic with simple optimization scripts in all cases. With the CK plans, coverage, minimal target volume dosage, and conformity index were significantly better, while no significant improvement could be shown regarding the 10 Gy volume. Multiobjective comparison for the irradiated target volumes was superior in the CK plan in 20 out of 23 cases and equivalent in 3 out of 23 cases. Multiobjective comparison for the treated patients was superior in the CK plan in all 16 cases. The results clearly demonstrate the superiority of the irradiation plan for CK compared to classical linac-SRS with circular collimators and microMLC. In particular, the average minimal target volume dose per patient, increased by 1.9 Gy, and at the same time a 14 % better conformation index seems to be an improvement with clinical relevance. (orig.) [German] Stereotaktische Radiochirurgie mit einem adaptierten Linearbeschleuniger (Linac-SRS) ist eine erfolgreiche und etablierte Therapieoption fuer Hirnmetastasen, benigne Hirntumoren und arteriovenoese Malformationen. Ziel war es, zu untersuchen, ob die mit einem CyberKnife (CK) erreichbare

  6. Stereotactic Radiosurgery: Treatment of Brain Metastasis Without Interruption of Systemic Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Colette J.; Kummerlowe, Megan N.; Redmond, Kristin J. [Department of Radiation Oncology, Johns Hopkins Hospital, Baltimore, Maryland (United States); Rigamonti, Daniele [Department of Neurosurgery, Johns Hopkins Hospital, Baltimore, Maryland (United States); Johns Hopkins Aramco Healthcare, Dhahran (Saudi Arabia); Lim, Michael K. [Department of Neurosurgery, Johns Hopkins Hospital, Baltimore, Maryland (United States); Kleinberg, Lawrence R., E-mail: kleinla@jhmi.edu [Department of Radiation Oncology, Johns Hopkins Hospital, Baltimore, Maryland (United States)

    2016-06-01

    Purpose: To evaluate the prevalence, outcomes, and toxicities of concurrent delivery of systemic therapy with stereotactic radiosurgery (SRS) for treatment of brain metastases. Methods and Materials: We conducted a retrospective review of 193 patients treated at our institution with SRS without prior whole-brain radiation therapy (WBRT) for brain metastases between 2009 and 2014. Outcome metrics included administration of concurrent systemic therapy, myelosuppression, neurotoxicity, and survival. Results: One hundred ninety-three patients with a median age of 61 years underwent a total of 291 SRS treatments. Thirty-seven percent of SRS treatments were delivered concurrently with systemic therapy, of which 46% were with conventional myelosuppressive chemotherapy, and 54% with targeted and immune therapy agents. Myelosuppression was minimal after treatment with both systemic therapy and SRS, with 14% grade 3-4 toxicity for lymphopenia and 4-9% for leukopenia, neutropenia, anemia, and thrombocytopenia. Neurotoxicity was also minimal after combined therapy, with no grade 4 and <5% grade 3 toxicity, 34% dexamethasone requirement, and 4% radiation necrosis, all similar to treatments with SRS alone. Median overall survival was similar after SRS alone (14.4 months) versus SRS with systemic therapy (12.9 months). In patients with a new diagnosis of primary cancer with brain metastasis, early treatment with concurrent systemic therapy and SRS correlated with improved survival versus SRS alone (41.6 vs 21.5 months, P<.05). Conclusions: Systemic therapy can be safely given concurrently with SRS for brain metastases: our results suggest minimal myelosuppression and neurotoxicity. Concurrent therapy is an attractive option for patients who have both intracranial and extracranial metastatic disease and may be particularly beneficial in patients with a new diagnosis of primary cancer with brain metastasis.

  7. 3D quantitative assessment of response to fractionated stereotactic radiotherapy and single-session stereotactic radiosurgery of vestibular schwannoma

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T. [The Johns Hopkins Hospital School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of Neuroradiology, Baltimore, MD (United States); University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Neuroradiology, Hamburg (Germany); Chapiro, J. [The Johns Hopkins Hospital School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of Interventional Radiology, Baltimore, MD (United States); Lin, M. [Philips Research North America, Ultrasound Imaging and Interventions (UII), Briarcliff Manor, NY (United States); Geschwind, J.F. [The Johns Hopkins Hospital School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of Interventional Radiology, Baltimore, MD (United States); Yale University School of Medicine, Department of Radiology and Imaging Science, New Haven, CT (United States); Kleinberg, L. [The Johns Hopkins University School of Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD (United States); Rigamonti, D.; Jusue-Torres, I.; Marciscano, A.E. [The Johns Hopkins University School of Medicine, Department of Neurological Surgery, Baltimore, MD (United States); Yousem, D.M. [The Johns Hopkins Hospital School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of Neuroradiology, Baltimore, MD (United States)

    2016-03-15

    To determine clinical outcome of patients with vestibular schwannoma (VS) after treatment with fractionated stereotactic radiotherapy (FSRT) and single-session stereotactic radiosurgery (SRS) by using 3D quantitative response assessment on MRI. This retrospective analysis included 162 patients who underwent radiation therapy for sporadic VS. Measurements on T1-weighted contrast-enhanced MRI (in 2-year post-therapy intervals: 0-2, 2-4, 4-6, 6-8, 8-10, 10-12 years) were taken for total tumour volume (TTV) and enhancing tumour volume (ETV) based on a semi-automated technique. Patients were considered non-responders (NRs) if they required subsequent microsurgical resection or developed radiological progression and tumour-related symptoms. Median follow-up was 4.1 years (range: 0.4-12.0). TTV and ETV decreased for both the FSRT and SRS groups. However, only the FSRT group achieved significant tumour shrinkage (p < 0.015 for TTV, p < 0.005 for ETV over time). The 11 NRs showed proportionally greater TTV (median TTV pre-treatment: 0.61 cm{sup 3}, 8-10 years after: 1.77 cm{sup 3}) and ETV despite radiation therapy compared to responders (median TTV pre-treatment: 1.06 cm{sup 3}; 10-12 years after: 0.81 cm{sup 3}; p = 0.001). 3D quantification of VS showed a significant decrease in TTV and ETV on FSRT-treated patients only. NR had significantly greater TTV and ETV over time. (orig.)

  8. Stereotactic radiosurgery vs. fractionated radiotherapy for tumor control in vestibular schwannoma patients: a systematic review.

    Science.gov (United States)

    Persson, Oscar; Bartek, Jiri; Shalom, Netanel Ben; Wangerid, Theresa; Jakola, Asgeir Store; Förander, Petter

    2017-06-01

    Repeated controlled studies have revealed that stereotactic radiosurgery is better than microsurgery for patients with vestibular schwannoma (VS) 18 years) patients with unilateral VS, followed for a median of >5 years, were eligible for inclusion. After screening titles and abstracts of the 1094 identified articles and systematically reviewing 98 of these articles, 19 were included. Patients with unilateral VS treated with radiosurgery were compared to patients treated with fractionated stereotactic radiotherapy. No randomized controlled trial (RCT) was identified. None of the identified controlled studies comparing SRS with FSRT were eligible according to the inclusion criteria. Nineteen case series on SRS (n = 17) and FSRT (n = 2) were included in the systematic review. Loss of tumor control necessitating a new VS-targeted intervention was found in an average of 5.0% of the patients treated with SRS and in 4.8% treated with FSRT. Mean deterioration ratio for patients with serviceable hearing before treatment was 49% for SRS and 45% for FSRT, respectively. The risk for facial nerve deterioration was 3.6% for SRS and 11.2% for FSRT and for trigeminal nerve deterioration 6.0% for SRS and 8.4% for FSRT. Since these results were obtained from case series, a regular meta-analysis was not attempted. SRS and FSRT are both noninvasive treatment alternatives for patients with VS with low rates of treatment failure in need of rescue therapy. In this selection of patients, the progression-free survival rates were on the order of 92-100% for both treatment options. There is a lack of high-quality studies comparing radiation therapy alternatives for patients with VS. Finally, 19 articles reported long-term tumor control after SRS, while only 2 articles reported long-term FSRT results, making effect estimates more uncertain for FSRT.

  9. Development of 3-D Radiosurgery Planning System Using IBM Personal Computer

    International Nuclear Information System (INIS)

    Suh, Tae Suk; Park, Charn Il; Ha, Sung Whan; Kang, Wee Saing; Suh, Doug Young; Park, Sung Hun

    1993-01-01

    Recently, stereotactic radiosurgery plan is required with the information of 3-D image and dose distribution. A project has been doing if developing LINAC based stereotactic radiosurgery since April 1991. The purpose of this research is to develop 3-D radiosurgery planning system using personal computer. The procedure of this research is based on two steps. The first step is to develop 3-D localization system, which input the image information of the patient, coordinate transformation, the position and shape of target, and patient contour into computer system using CT image and stereotactic frame. The second step is to develop 3-D dose planning system, which compute dose distribution on image plane, display on high resolution monitor both isodose distribution and patient image simultaneously and develop menu-driven planning system. This prototype of radiosurgery planning system was applied recently for several clinical cases. It was shown that our planning system is fast, accurate and efficient while making it possible to handle various kinds of image modalities such as angiography, CT and MRI. It makes it possible to develop general 3-D planning system using beam eye view or CT simulation in radiation therapy in future

  10. Stereotaxic radiosurgery for therapy of arterivenous malformation of the brain

    International Nuclear Information System (INIS)

    Beraha, J.; Feriancic, C.V.; Scaff, L.A.M.

    1987-01-01

    Since march 1983 we are attempting for the first time in Brazil to develop improvements on stereotactic radiosurgery techniques. We have been using the multifocal irradiation method attaching to this purpose the Barcia IV stereotactic frame to a 4 MV linear accelerator. We show details about the centralization technique and the security patterns in our system. From October 1983 to November 1986, 25 patients with arteriovenous malformations of the brain were submitted to a radiosurgery treatment in our service. Good results obtained on the follow-up from one to three years are analysed. (author)

  11. Study of the absorbed dose in small fields with absence of lateral electronic balance in stereotactic radiosurgery and radiotherapy with modulated intensity

    International Nuclear Information System (INIS)

    Vargas V, M. X.

    2013-01-01

    In this thesis we develop and experimental and theoretical study, using semi analytical techniques of the physical dosimetry for small and nonstandard fields for stereotactic radiosurgery (Srs) and intensity modulated radiation therapy (IMRT), with high energy photon beams from a BrainLAB system with cones at Instituto del Cancer SOLCA (Ecuador) and a Tomo Therapy Hi-Art system at Centro Oncologico de Chihuahua (Mexico). (Author)

  12. Stereotactic radiosurgery: the preferred management for patients with nonvestibular schwannomas?

    International Nuclear Information System (INIS)

    Pollock, Bruce E.; Foote, Robert L.; Stafford, Scott L.

    2002-01-01

    Purpose: To review patient outcomes after radiosurgery of nonvestibular schwannomas. Methods and Materials: From April 1992 to February 2000, 23 patients had radiosurgery at our center for nonvestibular schwannomas. Affected cranial nerves included the trochlear (n=1), trigeminal (n=10), jugular foramen region (n=10), and hypoglossal (n=2). Nine patients had undergone one or more prior tumor resections. One patient had a malignant schwannoma; 2 patients had neurofibromatosis. The median prescription isodose volume was 8.9 cc (range, 0.2 to 17.6 cc). The median tumor margin dose was 18 Gy (range, 12 to 20 Gy); the median maximum dose was 36 Gy (range, 24 to 40 Gy). The median follow-up after radiosurgery was 43 months (range, 12 to 111 months). Results: Twenty-two of 23 tumors (96%) were either smaller (n=12) or unchanged in size (n=10) after radiosurgery. One patient with a malignant schwannoma had tumor progression outside the irradiated volume despite having both radiosurgery and fractionated radiation therapy (50.4 Gy); he died 4 years later. Morbidity related to radiosurgery occurred in 4 patients (17%). Three of 10 patients with trigeminal schwannomas suffered new or worsened trigeminal dysfunction after radiosurgery. One patient with a hypoglossal schwannoma had eustachian tube dysfunction after radiosurgery. No patient with a lower cranial nerve schwannoma developed any hearing loss, facial weakness, or swallowing difficulty after radiosurgery. Conclusions: Although the reported number of patients having radiosurgery for nonvestibular schwannomas is limited, the high tumor control rates demonstrated after vestibular schwannoma radiosurgery should apply to these rare tumors. Compared to historical controls treated with surgical resection, radiosurgery appears to have less treatment-associated morbidity for nonvestibular schwannomas, especially for schwannomas involving the lower cranial nerves

  13. Anniversary Paper: The role of medical physicists in developing stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Benedict, Stanley H.; Bova, Frank J.; Clark, Brenda; Goetsch, Steven J.; Hinson, William H.; Leavitt, Dennis D.; Schlesinger, David J.; Yenice, Kamil M.

    2008-01-01

    This article is a tribute to the pioneering medical physicists over the last 50 years who have participated in the research, development, and commercialization of stereotactic radiosurgery (SRS) and stereotactic radiotherapy utilizing a wide range of technology. The authors have described the evolution of SRS through the eyes of physicists from its beginnings with the Gamma Knife in 1951 to proton and charged particle therapy; modification of commercial linacs to accommodate high precision SRS setups; the multitude of accessories that have enabled fine tuning patients for relocalization, immobilization, and repositioning with submillimeter accuracy; and finally the emerging technology of SBRT. A major theme of the article is the expanding role of the medical physicist from that of advisor to the neurosurgeon to the current role as a primary driver of new technology that has already led to an adaptation of cranial SRS to other sites in the body, including, spine, liver, and lung. SRS continues to be at the forefront of the impetus to provide technological precision for radiation therapy and has demonstrated a host of downstream benefits in improving delivery strategies for conventional therapy as well. While this is not intended to be a comprehensive history, and the authors could not delineate every contribution by all of those working in the pursuit of SRS development, including physicians, engineers, radiobiologists, and the rest of the therapy and dosimetry staff in this important and dynamic radiation therapy modality, it is clear that physicists have had a substantial role in the development of SRS and theyincreasingly play a leading role in furthering SRS technology

  14. Hypopituitarism after stereotactic radiosurgery for pituitary adenomas.

    Science.gov (United States)

    Xu, Zhiyuan; Lee Vance, Mary; Schlesinger, David; Sheehan, Jason P

    2013-04-01

    Studies of new-onset Gamma Knife stereotactic radiosurgery (SRS)-induced hypopituitarism in large cohort of pituitary adenoma patients with long-term follow-up are lacking. We investigated the outcomes of SRS for pituitary adenoma patients with regard to newly developed hypopituitarism. This was a retrospective review of patients treated with SRS at the University of Virginia between 1994 and 2006. A total of 262 patients with a pituitary adenoma treated with SRS were reviewed. Thorough endocrine assessment was performed immediately before SRS and in regular follow-ups. Assessment consisted of 24-hour urine free cortisol (patients with Cushing disease), serum adrenocorticotropic hormone, cortisol, follicle-stimulating hormone, luteinizing hormone, insulin-like growth factor-1, growth hormone, testosterone (men), prolactin, thyroid-stimulating hormone, and free T(4). Endocrine remission occurred in 144 of 199 patients with a functioning adenoma. Tumor control rate was 89%. Eighty patients experienced at least 1 axis of new-onset SRS-induced hypopituitarism. The new hypopituitarism rate was 30% based on endocrine follow-up ranging from 6 to 150 months; the actuarial rate of new pituitary hormone deficiency was 31.5% at 5 years after SRS. On univariate and multivariate analyses, variables regarding the increased risk of hypopituitarism included suprasellar extension and higher radiation dose to the tumor margin; there were no correlations among tumor volume, prior transsphenoidal adenomectomy, prior radiation therapy, and age at SRS. SRS provides an effective and safe treatment option for patients with a pituitary adenoma. Higher margin radiation dose to the adenoma and suprasellar extension were 2 independent predictors of SRS-induced hypopituitarism.

  15. Treatment planning optimization for linear accelerator radiosurgery

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Buatti, John M.; Bova, Francis J.; Friedman, William A.; Mendenhall, William M.

    1998-01-01

    Purpose: Linear accelerator radiosurgery uses multiple arcs delivered through circular collimators to produce a nominally spherical dose distribution. Production of dose distributions that conform to irregular lesions or conformally avoid critical neural structures requires a detailed understanding of the available treatment planning parameters. Methods and Materials: Treatment planning parameters that may be manipulated within a single isocenter to provide conformal avoidance and dose conformation to ellipsoidal lesions include differential arc weighting and gantry start/stop angles. More irregular lesions require the use of multiple isocenters. Iterative manipulation of treatment planning variables can be difficult and computationally expensive, especially if the effects of these manipulations are not well defined. Effects of treatment parameter manipulation are explained and illustrated. This is followed by description of the University of Florida Stereotactic Radiosurgery Treatment Planning Algorithm. This algorithm organizes the manipulations into a practical approach for radiosurgery treatment planning. Results: Iterative treatment planning parameters may be efficiently manipulated to achieve optimal treatment plans by following the University of Florida Treatment Planning Algorithm. The ability to produce conformal stereotactic treatment plans using the algorithm is demonstrated for a variety of clinical presentations. Conclusion: The standard dose distribution produced in linear accelerator radiosurgery is spherical, but manipulation of available treatment planning parameters may result in optimal dose conformation. The University of Florida Treatment Planning Algorithm organizes available treatment parameters to efficiently produce conformal radiosurgery treatment plans

  16. Tolerance of the Spinal Cord to Stereotactic Radiosurgery: Insights From Hemangioblastomas

    International Nuclear Information System (INIS)

    Daly, Megan E.; Choi, Clara Y.H.; Gibbs, Iris C.; Adler, John R.; Chang, Steven D.; Lieberson, Robert E.; Soltys, Scott G.

    2011-01-01

    Purpose: To evaluate spinal cord dose-volume effects, we present a retrospective review of stereotactic radiosurgery (SRS) treatments for spinal cord hemangioblastomas. Methods and Materials: From November 2001 to July 2008, 27 spinal hemangioblastomas were treated in 19 patients with SRS. Seventeen tumors received a single fraction with a median dose of 20 Gy (range, 18-30 Gy). Ten lesions were treated using 18-25 Gy in two to three sessions. Cord volumes receiving 8, 10, 12, 14, 16, 18, 20, 22, and 24 Gy and dose to 10, 100, 250, 500, 1000, and 2000 mm 3 of cord were determined. Multisession treatments were converted to single-fraction biologically effective dose (SFBED). Results: Single-fraction median cord D max was 22.7 Gy (range, 17.8-30.9 Gy). Median V10 was 454 mm 3 (range, 226-3543 mm 3 ). Median dose to 500 mm 3 cord was 9.5 Gy (range, 5.3-22.5 Gy). Fractionated median SFBED 3 cord D max was 14.1 Gy 3 (range, 12.3-19.4 Gy 3 ). Potential toxicities included a Grade 2 unilateral foot drop 5 months after SRS and 2 cases of Grade 1 sensory deficits. The actuarial 3-year local tumor control estimate was 86%. Conclusions: Despite exceeding commonly cited spinal cord dose constraints, SRS for spinal hemangioblastomas is safe and effective. Consistent with animal experiments, these data support a partial-volume tolerance model for the human spinal cord. Because irradiated cord volumes were generally small, application of these data to other clinical scenarios should be made cautiously. Further prospective studies of spinal radiosurgery are needed.

  17. Stereotactic Radiosurgery for Cushing Disease: Results of an International, Multicenter Study.

    Science.gov (United States)

    Mehta, Gautam U; Ding, Dale; Patibandla, Mohana Rao; Kano, Hideyuki; Sisterson, Nathaniel; Su, Yan-Hua; Krsek, Michal; Nabeel, Ahmed M; El-Shehaby, Amr; Kareem, Khaled A; Martinez-Moreno, Nuria; Mathieu, David; McShane, Brendan; Blas, Kevin; Kondziolka, Douglas; Grills, Inga; Lee, John Y; Martinez-Alvarez, Roberto; Reda, Wael A; Liscak, Roman; Lee, Cheng-Chia; Lunsford, L Dade; Vance, Mary Lee; Sheehan, Jason P

    2017-11-01

    Cushing disease (CD) due to adrenocorticotropic hormone-secreting pituitary tumors can be a management challenge. To better understand the outcomes of stereotactic radiosurgery (SRS) for CD and define its role in management. International, multicenter, retrospective cohort analysis. Ten medical centers participating in the International Gamma Knife Research Foundation. Patients with CD with >6 months endocrine follow-up. SRS using Gamma Knife radiosurgery. The primary outcome was control of hypercortisolism (defined as normalization of free urinary cortisol). Radiologic response and adverse radiation effects (AREs) were recorded. In total, 278 patients met inclusion criteria, with a mean follow-up of 5.6 years (0.5 to 20.5 years). Twenty-two patients received SRS as a primary treatment of CD. Mean margin dose was 23.7 Gy. Cumulative initial control of hypercortisolism was 80% at 10 years. Mean time to cortisol normalization was 14.5 months. Recurrences occurred in 18% with initial cortisol normalization. Overall, the rate of durable control of hypercortisolism was 64% at 10 years and 68% among patients who received SRS as a primary treatment. AREs included hypopituitarism (25%) and cranial neuropathy (3%). Visual deficits were related to treatment of tumor within the suprasellar cistern (P = 0.01), whereas both visual (P < 0.0001) and nonvisual cranial neuropathy (P = 0.02) were related to prior pituitary irradiation. SRS for CD is well tolerated and frequently results in control of hypercortisolism. However, recurrences can occur. SRS should be considered for patients with persistent hypercortisolism after pituitary surgery and as a primary treatment in those unfit for surgery. Long-term endocrine follow-up is essential after SRS. Copyright © 2017 Endocrine Society

  18. Cost-effectiveness Analysis of Stereotactic Radiosurgery Alone Versus Stereotactic Radiosurgery with Upfront Whole Brain Radiation Therapy for Brain Metastases.

    Science.gov (United States)

    Kim, H; Rajagopalan, M S; Beriwal, S; Smith, K J

    2017-10-01

    Stereotactic radiosurgery (SRS) alone or upfront whole brain radiation therapy (WBRT) plus SRS are the most commonly used treatment options for one to three brain oligometastases. The most recent randomised clinical trial result comparing SRS alone with upfront WBRT plus SRS (NCCTG N0574) has favoured SRS alone for neurocognitive function, whereas treatment options remain controversial in terms of cognitive decline and local control. The aim of this study was to conduct a cost-effectiveness analysis of these two competing treatments. A Markov model was constructed for patients treated with SRS alone or SRS plus upfront WBRT based on largely randomised clinical trials. Costs were based on 2016 Medicare reimbursement. Strategies were compared using the incremental cost-effectiveness ratio (ICER) and effectiveness was measured in quality-adjusted life years (QALYs). One-way and probabilistic sensitivity analyses were carried out. Strategies were evaluated from the healthcare payer's perspective with a willingness-to-pay threshold of $100 000 per QALY gained. In the base case analysis, the median survival was 9 months for both arms. SRS alone resulted in an ICER of $9917 per QALY gained. In one-way sensitivity analyses, results were most sensitive to variation in cognitive decline rates for both groups and median survival rates, but the SRS alone remained cost-effective for most parameter ranges. Based on the current available evidence, SRS alone was found to be cost-effective for patients with one to three brain metastases compared with upfront WBRT plus SRS. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  19. Hypofractionated stereotactic irradiation. Basic and clinical researches

    International Nuclear Information System (INIS)

    Shibamoto, Yuta; Miyakawa, Akifumi; Iwata, Hiromitsu; Otsuka, Shinya; Ogino, Hiroyuki; Ayakawa, Shiho

    2011-01-01

    Hypofractionated stereotactic radiotherapy (SRT) has a number of biological advantages over single-session radiosurgery. An apparent trend is seen in the clinic towards shift from the latter to the former; however, there is no adequate model to convert single doses to hypofractionated doses. The linear-quadratic model overestimates the effect of single-fraction radiation. This should be kept in mind in evaluating the doses of stereotactic irradiation. ''Biological effective dose'' should not be used in radiosurgery and hypofractionated SRT. Clinically, we have used 3- to 10-fraction SRT for acoustic neuroma and benign skull base tumors using cyberknife and tomotherapy. Preliminary results are encouraging. (author)

  20. Stereotactic radiotherapy in pediatric indications

    International Nuclear Information System (INIS)

    Bernier-Chastagner, V.; Supiot, S.; Carrie, C.; Helfre, S.

    2012-01-01

    Stereotactic radiotherapy is a very high precision procedure, which has been limited to radiosurgery for a long time. Technological improvements allowed the development of radiotherapy in stereotactic conditions, leading to a lot of innovations. Previously indicated for cerebral pathologies, this procedure is now developed for extra-cerebral locations. In paediatrics, stereotactic radiotherapy is still limited, delivered precociously, due to the possibility of long-term late effects that needs to be addressed. This review reports the different useful conditions, technical evolutions, and the current validated paediatric indications, with differences from adults, and future directions. (authors)

  1. Initial clinical results of linac-based stereotactic radiosurgery and stereotactic radiotherapy for pituitary adenomas

    International Nuclear Information System (INIS)

    Mitsumori, Michihide; Shrieve, Dennis C.; Alexander, Eben; Kaiser, Ursula B.; Richardson, Gary E.; Black, Peter McL.; Loeffler, Jay S.

    1998-01-01

    Purpose: To retrospectively evaluate the initial clinical results of stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (SRT) for pituitary adenomas with regard to tumor and hormonal control and adverse effects of the treatment. Subjects and Methods: Forty-eight patients with pituitary adenoma who underwent SRS or SRT between September 1989 and September 1995 were analyzed. Of these, 18 received SRS and 30 received SRT. The median tumor volumes were 1.9 cm 3 for SRS and 5.7 cm 3 for SRT. Eleven of the SRS and 18 of the SRT patients were hormonally active at the time of the initial diagnosis. Four of the SRS and none of the SRT patients had a history of prior radiation therapy. Both SRS and SRT were performed using a dedicated stereotactic 6-MV linear accelerator (LINAC). The dose and normalization used for the SRS varied from 1000 cGy at 85% of the isodose line to 1500 cGy at 65% of the isodose line. For SRT patients, a total dose of 4500 cGy at 90% or 95% of the isodose line was delivered in 25 fractions of 180 cGy daily doses. Results: Disease control--The three year tumor control rate was 91.1% (100% for SRS and 85.3% for SRT). Normalization of the hormonal abnormality was achieved in 47% of the 48 patients (33% for SRS and 54% for SRT). The average time required for normalization was 8.5 months for SRS and 18 months for SRT. Adverse effects--The 3-year rate of freedom from central nervous system adverse effects was 89.7% (72.2% for SRS and 100% for SRT). Three patients who received SRS for a tumor in the cavernous sinus developed a ring enhancement in the temporal lobe as shown by follow-up magnetic resonance imaging. Two of these cases were irreversible and were considered to be radiation necrosis. None of the 48 patients developed new neurocognitive or visual disorders attributable to the irradiation. The incidence of endocrinological adverse effects were similar in the two groups, resulting in 3-year rates of freedom from newly

  2. Characterisation of a plastic scintillation detector to be used in a multicentre stereotactic radiosurgery dosimetry audit

    Science.gov (United States)

    Dimitriadis, A.; Patallo, I. Silvestre; Billas, I.; Duane, S.; Nisbet, A.; Clark, C. H.

    2017-11-01

    Scintillation detectors are considered highly suitable for dosimetric measurement of small fields in radiotherapy due to their near-tissue equivalence and their small size. A commercially available scintillation detector, the Exradin W1 (Standard Imaging, Middleton, USA), has been previously characterised by two independent studies (Beierholm et al., 2014; Carrasco et al., 2015a, 2015b) but the results from these publications differed in some aspects (e.g. energy dependence, long term stability). The respective authors highlighted the need for more studies to be published (Beierholm et al., 2015; Carrasco et al., 2015a, 2015b). In this work, the Exradin W1 was characterised in terms of dose response, dependence on dose rate, energy, temperature and angle of irradiation, and long-term stability. The observed dose linearity, short-term repeatability and temperature dependence were in good agreement with previously published data. Appropriate corrections should therefore be applied, where possible, in order to achieve measurements with low-uncertainty. The angular dependence was characterised along both the symmetrical and polar axis of the detector for the first time in this work and a dose variation of up to 1% was observed. The response of the detector was observed to decrease at a rate of approximately 1.6% kGy-1 for the first 5 kGy delivered, and then stabilised to 0.2% kGy-1 in the subsequent 20 kGy. The main goal of this work was to assess the suitability of the Exradin W1 for use in dose verification measurements for stereotactic radiosurgery. The results obtained confirm that the detector is suitable for use in such situations. The detector is now utilised in a multi-centre stereotactic radiosurgery dosimetric audit, with the application of appropriate correction factors.

  3. Development of a head phantom to be used for quality control in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Barbosa, Nilseia Aparecida

    2010-05-01

    It was designed and developed a geometric acrylic head phantom (GHP) for Quality Assurance (QA) in Stereotactic Radiosurgery (SRS). Inside the phantom there are inserts that are able to accommodate acrylic targets representing the tumor tissue and organ at risk in the region cranial brain, the brain stem. The tumor tissue is represented by two semi-spheres of acrylic with a diameter of 13.0 mm and cavities in the central region for accommodation of a TLD-100 detector and a small radiochromic EBT Gafchromic filmstrip. The brain stem is represented by the two parts of acrylic cylinder with a diameter 18.0 mm, 38.0 mm length and cavities along the central region to accommodate the 5 detectors TLD-100 and yet another of EBT film. The distance tumor - brain stem is 2.0 mm. The experimental setup was filled with water, attached to the stereotactic frame to determine the coordinates of the target and underwent computed tomography (CT). Cf images were transferred to the SRS planning system BrainLab (BrainScan). The contours of the lesion and organ at risk were delineated and, through the technique of multiple circular arcs, the planning was conduced with five arches, one isocenter and a collimator of 17.5 mm from the combination between the table and gantry . The dose delivered to the isocenter of the lesion was 3.0 Gy and the total coverage of tumor volume corresponds to the 75% isodose. This experimental arrangement is subjected to radiosurgery treatment, after which the dosimeters are evaluated and their responses compared with the values of planned doses. The linear accelerator used was a Varian CLlNAC 2300 CID, photon beam of 6 MV, installed at the National Cancer Institute (INCA). For verification of dose distributions in 3D, the films were irradiated in three planes: sagittal, caronal and axial. The .films were scanned and digitized on a scanner Microtek ScanMaker 9800XL model. The dose distributions in irradiated films were compared with the distributions of doses

  4. Machine-Specific Magnetic Resonance Imaging Quality Control Procedures for Stereotactic Radiosurgery Treatment Planning.

    Science.gov (United States)

    Fatemi, Ali; Taghizadeh, Somayeh; Yang, Claus Chunli; R Kanakamedala, Madhava; Morris, Bart; Vijayakumar, Srinivasan

    2017-12-18

    Purpose Magnetic resonance (MR) images are necessary for accurate contouring of intracranial targets, determination of gross target volume and evaluation of organs at risk during stereotactic radiosurgery (SRS) treatment planning procedures. Many centers use magnetic resonance imaging (MRI) simulators or regular diagnostic MRI machines for SRS treatment planning; while both types of machine require two stages of quality control (QC), both machine- and patient-specific, before use for SRS, no accepted guidelines for such QC currently exist. This article describes appropriate machine-specific QC procedures for SRS applications. Methods and materials We describe the adaptation of American College of Radiology (ACR)-recommended QC tests using an ACR MRI phantom for SRS treatment planning. In addition, commercial Quasar MRID 3D and Quasar GRID 3D phantoms were used to evaluate the effects of static magnetic field (B 0 ) inhomogeneity, gradient nonlinearity, and a Leksell G frame (SRS frame) and its accessories on geometrical distortion in MR images. Results QC procedures found in-plane distortions (Maximum = 3.5 mm, Mean = 0.91 mm, Standard deviation = 0.67 mm, >2.5 mm (%) = 2) in X-direction (Maximum = 2.51 mm, Mean = 0.52 mm, Standard deviation = 0.39 mm, > 2.5 mm (%) = 0) and in Y-direction (Maximum = 13. 1 mm , Mean = 2.38 mm, Standard deviation = 2.45 mm, > 2.5 mm (%) = 34) in Z-direction and < 1 mm distortion at a head-sized region of interest. MR images acquired using a Leksell G frame and localization devices showed a mean absolute deviation of 2.3 mm from isocenter. The results of modified ACR tests were all within recommended limits, and baseline measurements have been defined for regular weekly QC tests. Conclusions With appropriate QC procedures in place, it is possible to routinely obtain clinically useful MR images suitable for SRS treatment planning purposes. MRI examination for SRS planning can benefit from the improved localization and planning

  5. Stereotactic irradiation without whole-brain irradiation for single brain metastasis

    International Nuclear Information System (INIS)

    Shirato, Hiroki; Takamura, Akio; Tomita, Masayoshi; Suzuki, Keishiro; Nishioka, Takashi; Isu, Toyohiko; Kato, Tsutomu; Sawamura, Yutaka; Miyamachi, Keikichi; Abe, Hiroshi; Miyasaka, Kazuo

    1997-01-01

    Purpose: The effectiveness of stereotactic irradiation (STI) alone without whole-brain irradiation (WBI) for a single metastatic brain tumor was analyzed retrospectively. Methods and Materials: Forty-four patients with this condition were treated using radiosurgery (RS) alone or fractionated stereotactic radiotherapy (FSR) without WBI. Results: The initial response rate was 92% and the overall local control rate was 84% (37 of 44 patients). A total of 39% (18 of 44) of patients experienced intracranial relapse outside the initial target area. Forty-eight percent (21 of 44) of patients required salvage treatment for intracranial relapse. All 7 patients who received WBI as salvage treatment required no further salvage treatment, but 5 of the 14 patients who received salvage STI without WBI required three to four treatments for brain metastasis. Late radiation damage was not seen with initial treatment but was observed with retreatment. The overall median survival time was 261 days, with a standard error of 64 days. Actuarial survival at 12 and 24 months was 34% and 9%, respectively. The actuarial survival rate was significantly affected by the existence of active extracranial disease (p = 0.041). Conclusion: The high response rate and short treatment period of STI alone are advantageous in the treatment of single brain metastasis in patients with active extracranial disease with WBI reserved for relapse. Because of the low complication rate, STI alone may be also useful in patients with good prognosis, without extracranial disease

  6. Repeat Courses of Stereotactic Radiosurgery (SRS), Deferring Whole-Brain Irradiation, for New Brain Metastases After Initial SRS

    Energy Technology Data Exchange (ETDEWEB)

    Shultz, David B.; Modlin, Leslie A.; Jayachandran, Priya; Von Eyben, Rie; Gibbs, Iris C. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Choi, Clara Y.H. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Department of Radiation Oncology, Santa Clara Valley Medical Center, San Jose, California (United States); Chang, Steven D.; Harsh, Griffith R.; Li, Gordon; Adler, John R. [Department of Neurosurgery, Stanford University School of Medicine, Stanford, California (United States); Hancock, Steven L. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Soltys, Scott G., E-mail: sgsoltys@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States)

    2015-08-01

    Purpose: To report the outcomes of repeat stereotactic radiosurgery (SRS), deferring whole-brain radiation therapy (WBRT), for distant intracranial recurrences and identify factors associated with prolonged overall survival (OS). Patients and Methods: We retrospectively identified 652 metastases in 95 patients treated with 2 or more courses of SRS for brain metastases, deferring WBRT. Cox regression analyzed factors predictive for OS. Results: Patients had a median of 2 metastases (range, 1-14) treated per course, with a median of 2 courses (range, 2-14) of SRS per patient. With a median follow-up after first SRS of 15 months (range, 3-98 months), the median OS from the time of the first and second course of SRS was 18 (95% confidence interval [CI] 15-24) and 11 months (95% CI 6-17), respectively. On multivariate analysis, histology, graded prognostic assessment score, aggregate tumor volume (but not number of metastases), and performance status correlated with OS. The 1-year cumulative incidence, with death as a competing risk, of local failure was 5% (95% CI 4-8%). Eighteen (24%) of 75 deaths were from neurologic causes. Nineteen patients (20%) eventually received WBRT. Adverse radiation events developed in 2% of SRS sites. Conclusion: Multiple courses of SRS, deferring WBRT, for distant brain metastases after initial SRS, seem to be a safe and effective approach. The graded prognostic assessment score, updated at each course, and aggregate tumor volume may help select patients in whom the deferral of WBRT might be most beneficial.

  7. Dosimetry of small circular beams of high energy photons for stereotactic radiosurgery and radiotherapy: the use of small ionization chambers

    International Nuclear Information System (INIS)

    Mazal, A.; Gaboriauid, G.; Zefkili, S.; Rosenwald, J.C.; Boutaudon, S.; Pontvert, D.

    1999-01-01

    The irradiation of small targets in the brain in a singe fraction (radiosurgery) or with a fractionated approach (stereotactic radiosurgery) with small beams of photons requires specific conditions to measure and to model the dosimetric data needed for treatment planning. In this work we present the method and materials adopted in our institution since 1988 to perform the dosimetry of high energy (6-23) circular photon beams with diameters ranging from 10 to 40 mm at the isocenter of linear accelerators, and its evolution as new dosimetric material became commercially available. in circular ionization chambers of small dimensions. We want to answer the following questions: Which are the minimal basic data needed to model small circular beams of high energy photons? Can we extrapolate or convert data from conventional data of larger beams? Which are the detectors well adapted for these kind of measurements and for which range of beam sizes?

  8. Toxicity of Gamma Knife Radiosurgery in the Treatment of Intracranial Tumors in Patients With Collagen Vascular Diseases or Multiple Sclerosis

    International Nuclear Information System (INIS)

    Lowell, Dot; Tatter, Stephen B.; Bourland, J. Daniel; Guzman, Allan F. de; Ekstrand, Kenneth E.; Ellis, Thomas L.; Lovato, James F.; McMullen, Kevin P.; Munley, Michael T.; Shaw, Edward G.; Urbanic, James J.; Chan, Michael D.

    2011-01-01

    Purpose: To assess toxicity in patients with either a collagen vascular disease (CVD) or multiple sclerosis (MS) treated with intracranial radiosurgery. Methods and Materials: Between January 2004 and April 2009, 6 patients with MS and 14 patients with a CVD were treated with Gamma Knife radiosurgery (GKRS) for intracranial tumors. Treated lesions included 15 total brain metastases in 7 patients, 11 benign brain tumors, 1 low grade glioma, and 1 cavernous malformation. Toxicities were graded by the Radiation Therapy Oncology Group Acute/Late Radiation Morbidity Scoring Criteria. “Rare toxicities” were characterized as those reported in the scientific literature at an incidence of 3 (range, 0.14–7.8 cm 3 ). Of the 14 patients with CVD, none experienced a Grade 3 or 4 toxicity or a toxicity characterized as rare. Of the 6 patients with MS, 3 experienced rare toxicities, and two of these were Grade 3 toxicities. Rare complications included a patient experiencing both communicating hydrocephalus and facial nerve palsy, as well as 2 additional patients with motor cranial nerve palsy. High-grade toxicities included the patient with an acoustic neuroma requiring ventriculoperitoneal shunt placement for obstructive hydrocephalus, and 1 patient with a facial nerve schwannoma who experienced permanent facial nerve palsy. Interval between radiosurgery and high-grade toxicities ranged from 1 week to 4 months. Conclusions: Our series suggests that patients with MS who receive GKRS may be at increased risk of rare and high-grade treatment-related toxicity. Given the time course of toxicity, treatment-related edema or demyelination represent potential mechanisms.

  9. IRLED-based patient localization for linac radiosurgery

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Bova, Francis J.; Friedman, William A.; Buatti, John M.; Moore, Russell D.; Mendenhall, William M.

    1998-01-01

    Purpose: Currently, precise stereotactic radiosurgery delivery is possible with the Gamma Knife or floor-stand linear accelerator (linac) systems. Couch-mounted linac radiosurgery systems, while less expensive and more flexible than other radiosurgery delivery systems, have not demonstrated a comparable level of precision. This article reports on the development and testing of an optically guided positioning system designed to improve the precision of patient localization in couch-mounted linac radiosurgery systems. Methods and Materials: The optically guided positioning system relies on detection of infrared light-emitting diodes (IRLEDs) attached to a standard target positioner. The IRLEDs are monitored by a commercially available camera system that is interfaced to a personal computer. An IRLED reference is established at the center of stereotactic space, and the computer reports the current position of the IRLEDs relative to this reference position. Using this readout from the computer, the correct stereotactic coordinate can be set directly. Results: Bench testing was performed to compare the accuracy of the optically guided system with that of a floor-stand system, that can be considered an absolute reference. This testing showed that coordinate localization using the IRLED system to track translations agreed with the absolute to within 0.1 ± 0.1 mm. As rotations for noncoplanar couch angles were included, the inaccuracy was increased to 0.2 ± 0.1 mm. Conclusions: IRLED technology improves the accuracy of patient localization relative to the linac isocenter in comparison with conventional couch-mounted systems. Further, the patient's position can be monitored in real time as the couch is rotated for all treatment angles. Thus, any errors introduced by couch inaccuracies can be detected and corrected

  10. Assessment of absorbed dose to thyroid, parotid and ovaries in patients undergoing Gamma Knife radiosurgery

    International Nuclear Information System (INIS)

    Hasanzadeh, H; Sharafi, A; Verdi, M Allah; Nikoofar, A

    2006-01-01

    Stereotactic radiosurgery was originally introduced by Lars Leksell in 1951. This treatment refers to the noninvasive destruction of an intracranial target localized stereotactically. The purpose of this study was to identify the dose delivered to the parotid, ovaries, testis and thyroid glands during the Gamma Knife radiosurgery procedure. A three-dimensional, anthropomorphic phantom was developed using natural human bone, paraffin and sodium chloride as the equivalent tissue. The phantom consisted of a thorax, head and neck and hip. In the natural places of the thyroid, parotid (bilateral sides) and ovaries (midline), some cavities were made to place TLDs. Three TLDs were inserted in a batch with 1 cm space between the TLDs and each batch was inserted into a single cavity. The final depth of TLDs was 3 cm from the surface for parotid and thyroid and was 15 cm for the ovaries. Similar batches were placed superficially on the phantom. The phantom was gamma irradiated using a Leksell model C Gamma Knife unit. Subsequently, the same batches were placed superficially over the thyroid, parotid, testis and ovaries in 30 patients (15 men and 15 women) who were undergoing radiosurgery treatment for brain tumours. The mean dosage for treating these patients was 14.48 ± 3.06 Gy (10.5-24 Gy) to a mean tumour volume of 12.30 ± 9.66 cc (0.27-42.4 cc) in the 50% isodose curve. There was no significant difference between the superficial and deep batches in the phantom studies (P-value < 0.05). The mean delivered doses to the parotid, thyroid, ovaries and testis in human subjects were 21.6 ± 15.1 cGy, 9.15 ± 3.89 cGy, 0.47 ± 0.3 cGy and 0.53 ± 0.31 cGy, respectively. The data can be used in making decisions for special clinical situations such as treating pregnant patients or young patients with benign lesions who need radiosurgery for eradication of brain tumours

  11. Performance of a Novel Repositioning Head Frame for Gamma Knife Perfexion and Image-Guided Linac-Based Intracranial Stereotactic Radiotherapy

    International Nuclear Information System (INIS)

    Ruschin, Mark; Nayebi, Nazanin; Carlsson, Per; Brown, Kevin

    2010-01-01

    Purpose: To evaluate the geometric positioning and immobilization performance of a vacuum bite-block repositioning head frame (RHF) system for Perfexion (PFX-SRT) and linac-based intracranial image-guided stereotactic radiotherapy (SRT). Methods and Materials: Patients with intracranial tumors received linac-based image-guided SRT using the RHF for setup and immobilization. Three hundred thirty-three fractions of radiation were delivered in 12 patients. The accuracy of the RHF was estimated for linac-based SRT with online cone-beam CT (CBCT) and for PFX-SRT with a repositioning check tool (RCT) and offline CBCT. The RCT's ability to act as a surrogate for anatomic position was estimated through comparison to CBCT image matching. Immobilization performance was evaluated daily with pre- and postdose delivery CBCT scans and RCT measurements. Results: The correlation coefficient between RCT- and CBCT-reported displacements was 0.59, 0.75, 0.79 (Right, Superior, and Anterior, respectively). For image-guided linac-based SRT, the mean three-dimensional (3D) setup error was 0.8 mm with interpatient (Σ) and interfraction (σ) variations of 0.1 and 0.4 mm, respectively. For PFX-SRT, the initial, uncorrected mean 3D positioning displacement in stereotactic coordinates was 2.0 mm, with Σ = 1.1 mm and σ = 0.8 mm. Considering only RCT setups o in pitch. The mean 3D intrafraction motion was 0.4 ± 0.3 mm. Conclusion: The RHF provides excellent immobilization for intracranial SRT and PFX-SRT. Some small systematic uncertainties in stereotactic positioning exist and must be considered when generating PFX-SRT treatment plans. The RCT provides reasonable surrogacy for internal anatomic displacement.

  12. Embolization with Gamma Knife Radiosurgery of Giant Intracranial Arteriovenous Malformations.

    Science.gov (United States)

    Chun, Dong Hyun; Kim, Moo Seong; Kim, Sung Tae; Paeng, Sung Hwa; Jeong, Hae Woong; Lee, Won Hee

    2016-01-01

    Giant arteriovenous malformations (i.e., those greater than 6 cm maximum diameter or volume > 33 cc) are difficult to treat and often carry higher treatment morbidity and mortality rates. In our study, we reviewed the angiographic results and clinical outcomes for 11 patients with giant arteriovenous malformations who were treated between 1994 and 2012. The patients selected included 9 males (82%) and 2 females (18%). Their presenting symptoms were hemorrhage (n=2; 18%), seizure (n=7; 64%), and headache (n=2; 12%). Nine patients were Spetzler-Martin Grade III, 2 were Spetzler-Martin Grade IV. The mean arteriovenous malformation volume was 41 cc (33-52 cc). The mean age of the patients was 45.1 years (24-57 years) and the mean radiation dose delivered to the margin of the nidus was 14.2 Gy. Ten patients received pre-Gamma Knife radiosurgery embolization and Gamma Knife radiosurgery, 1 patient received pre-Gamma Knife radiosurgery embolization and Gamma Knife radiosurgery twice and the interval between Gamma Knife radiosurgeries was 3 months. The complete obliteration rate following Gamma Knife radiosurgery was 36%, subtotal obliteration ( > 70% decreased size of nidus) was 36%, and partial obliteration was 28%. One patient experienced a small hemorrhage after embolization. Combined embolization and Gamma Knife radiosurgery showed successful obliteration of the arteriovenous malformation nidus. The use of embolization to initially reduce nidus size followed by Gamma Knife radiosurgery improves the treatment results. Repeated Gamma Knife radiosurgery should be a treatment option when there is a small nidus remnant.

  13. Clinical results of stereotactic hellium-ion radiosurgery of the pituitary gland at Lawrence Berkeley Laboratory

    International Nuclear Information System (INIS)

    Levy, R.P.; Fabrikant, J.I.; Lyman, J.T.; Frankel, K.A.; Phillips, M.H.; Lawrence, J.H.; Tobias, C.A.

    1989-12-01

    The first therapeutic clinical trial using accelerated heavy-charged particles in humans was performed at Lawrence Berkeley Laboratory (LBL) for the treatment of various endocrine and metabolic disorders of the pituitary gland, and as suppressive therapy for adenohypophyseal hormone-responsive carcinomas and diabetic retinopathy. In acromegaly, Cushing's disease, Nelson's syndrome and prolactin-secreting tumors, the therapeutic goal in the 433 patients treated has been to destroy or inhibit the growth of the pituitary tumor and control hormonal hypersecretion, while preserving a functional rim of tissue with normal hormone-secreting capacity, and minimizing neurologic injury. An additional group of 34 patients was treated for nonsecreting chromophobe adenomas. This paper discusses the methods and results of stereotactic helium-ion radiosurgery of the pituitary gland at Lawrence Berkeley Laboratory. 11 refs

  14. Clinical results of stereotactic hellium-ion radiosurgery of the pituitary gland at Lawrence Berkeley Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R.P.; Fabrikant, J.I.; Lyman, J.T.; Frankel, K.A.; Phillips, M.H.; Lawrence, J.H.; Tobias, C.A.

    1989-12-01

    The first therapeutic clinical trial using accelerated heavy-charged particles in humans was performed at Lawrence Berkeley Laboratory (LBL) for the treatment of various endocrine and metabolic disorders of the pituitary gland, and as suppressive therapy for adenohypophyseal hormone-responsive carcinomas and diabetic retinopathy. In acromegaly, Cushing's disease, Nelson's syndrome and prolactin-secreting tumors, the therapeutic goal in the 433 patients treated has been to destroy or inhibit the growth of the pituitary tumor and control hormonal hypersecretion, while preserving a functional rim of tissue with normal hormone-secreting capacity, and minimizing neurologic injury. An additional group of 34 patients was treated for nonsecreting chromophobe adenomas. This paper discusses the methods and results of stereotactic helium-ion radiosurgery of the pituitary gland at Lawrence Berkeley Laboratory. 11 refs.

  15. Radical stereotactic radiosurgery with real-time tumor motion tracking in the treatment of small peripheral lung tumors

    Directory of Open Access Journals (Sweden)

    Chang Thomas

    2007-10-01

    Full Text Available Abstract Background Recent developments in radiotherapeutic technology have resulted in a new approach to treating patients with localized lung cancer. We report preliminary clinical outcomes using stereotactic radiosurgery with real-time tumor motion tracking to treat small peripheral lung tumors. Methods Eligible patients were treated over a 24-month period and followed for a minimum of 6 months. Fiducials (3–5 were placed in or near tumors under CT-guidance. Non-isocentric treatment plans with 5-mm margins were generated. Patients received 45–60 Gy in 3 equal fractions delivered in less than 2 weeks. CT imaging and routine pulmonary function tests were completed at 3, 6, 12, 18, 24 and 30 months. Results Twenty-four consecutive patients were treated, 15 with stage I lung cancer and 9 with single lung metastases. Pneumothorax was a complication of fiducial placement in 7 patients, requiring tube thoracostomy in 4. All patients completed radiation treatment with minimal discomfort, few acute side effects and no procedure-related mortalities. Following treatment transient chest wall discomfort, typically lasting several weeks, developed in 7 of 11 patients with lesions within 5 mm of the pleura. Grade III pneumonitis was seen in 2 patients, one with prior conventional thoracic irradiation and the other treated with concurrent Gefitinib. A small statistically significant decline in the mean % predicted DLCO was observed at 6 and 12 months. All tumors responded to treatment at 3 months and local failure was seen in only 2 single metastases. There have been no regional lymph node recurrences. At a median follow-up of 12 months, the crude survival rate is 83%, with 3 deaths due to co-morbidities and 1 secondary to metastatic disease. Conclusion Radical stereotactic radiosurgery with real-time tumor motion tracking is a promising well-tolerated treatment option for small peripheral lung tumors.

  16. Feasibility evaluation of a motion detection system with face images for stereotactic radiosurgery.

    Science.gov (United States)

    Yamakawa, Takuya; Ogawa, Koichi; Iyatomi, Hitoshi; Kunieda, Etsuo

    2011-01-01

    In stereotactic radiosurgery we can irradiate a targeted volume precisely with a narrow high-energy x-ray beam, and thus the motion of a targeted area may cause side effects to normal organs. This paper describes our motion detection system with three USB cameras. To reduce the effect of change in illuminance in a tracking area we used an infrared light and USB cameras that were sensitive to the infrared light. The motion detection of a patient was performed by tracking his/her ears and nose with three USB cameras, where pattern matching between a predefined template image for each view and acquired images was done by an exhaustive search method with a general-purpose computing on a graphics processing unit (GPGPU). The results of the experiments showed that the measurement accuracy of our system was less than 0.7 mm, amounting to less than half of that of our previous system.

  17. A Phase 2 Trial of Stereotactic Radiosurgery Boost After Surgical Resection for Brain Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, Cameron [Human Oncology and Pathogenesis Program, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurosurgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Yang, T. Jonathan [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Hilden, Patrick; Zhang, Zhigang [Department of Epidemiology and Biostatistics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Chan, Kelvin; Yamada, Yoshiya [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Chan, Timothy A. [Human Oncology and Pathogenesis Program, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Lymberis, Stella C. [Department of Radiation Oncology, New York University Langone Medical Center, New York, New York (United States); Narayana, Ashwatha [Department of Radiation Oncology, Greenwich Hospital, Greenwich, Connecticut (United States); Tabar, Viviane; Gutin, Philip H. [Department of Neurosurgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Ballangrud, Åse [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Lis, Eric [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Beal, Kathryn, E-mail: BealK@MSKCC.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2014-01-01

    Purpose: To evaluate local control after surgical resection and postoperative stereotactic radiosurgery (SRS) for brain metastases. Methods and Materials: A total of 49 patients (50 lesions) were enrolled and available for analysis. Eligibility criteria included histologically confirmed malignancy with 1 or 2 intraparenchymal brain metastases, age ≥18 years, and Karnofsky performance status (KPS) ≥70. A Cox proportional hazard regression model was used to test for significant associations between clinical factors and overall survival (OS). Competing risks regression models, as well as cumulative incidence functions, were fit using the method of Fine and Gray to assess the association between clinical factors and both local failure (LF; recurrence within surgical cavity or SRS target), and regional failure (RF; intracranial metastasis outside of treated volume). Results: The median follow-up was 12.0 months (range, 1.0-94.1 months). After surgical resection, 39 patients with 40 lesions were treated a median of 31 days (range, 7-56 days) later with SRS to the surgical bed to a median dose of 1800 cGy (range, 1500-2200 cGy). Of the 50 lesions, 15 (30%) demonstrated LF after surgery. The cumulative LF and RF rates were 22% and 44% at 12 months. Patients who went on to receive SRS had a significantly lower incidence of LF (P=.008). Other factors associated with improved local control include non-small cell lung cancer histology (P=.048), tumor diameter <3 cm (P=.010), and deep parenchymal tumors (P=.036). Large tumors (≥3 cm) with superficial dural/pial involvement showed the highest risk for LF (53.3% at 12 months). Large superficial lesions treated with SRS had a 54.5% LF. Infratentorial lesions were associated with a higher risk of developing RF compared to supratentorial lesions (P<.001). Conclusions: Postoperative SRS is associated with high rates of local control, especially for deep brain metastases <3 cm. Tumors ≥3 cm with superficial dural

  18. Linear accelerator radiosurgery in treatment of central neurocytomas

    International Nuclear Information System (INIS)

    Martin, J.M.; Katati, M.; Arjona, V.; Lopez, E.; Olivares, G.; Hernandez, V.; Bullejos, J.A.; Arregui, G.; Busquier, H.; Minguez, A.

    2003-01-01

    The purpose of this report was to review our experience with stereotactic radiosurgery in the management of patients with residual neurocytomas after initial surgery. Between October 1996 and December 2001, four patients with central neurocytoma were treated by surgery and subsequently underwent linear accelerator (LINAC) radiosurgery. Two of the patients were cured, one exhibited a significant reduction in tumour size and the fourth remains stable. All four patients are alive and well. In cases of small residual tumours or recurrences radio-surgery allows open surgery to be avoided and is a safe and potentially effective approach. (author)

  19. The effects of pentoxifylline on the survival of human glioma cells with continuous and intermittent stereotactic radiosurgery irradiation

    International Nuclear Information System (INIS)

    Eley, Kerry W.; Benedict, Stanley H.; Chung, Theodore D.K.; Kavanagh, Brian D.; Broaddus, William C.; Schmidt-Ullrich, Rupert K.A.; Lin, P.-S.

    2002-01-01

    Purpose: In linac-based stereotactic radiosurgery, treatment is delivered intermittently via multiple individual small radiotherapy arcs. The time lapses between the individual arcs permit greater damage repair and increased tumor cell survival in comparison with continuous irradiation. Because pentoxifylline (PTX) has been reported to prevent radiation-induced cell cycle arrest at the G2/M checkpoint, where damage repair is critically linked to cell survival, we hypothesized that PTX would exert a favorable radiosensitization effect by reducing the recovery observed during intermittent stereotactic radiosurgery. Methods and Materials: The human glioma cell line T98G was used to study the effects of continuous vs. intermittent irradiation with or without PTX. Cell cycle patterns were studied using flow cytometry. Clonogenic assays of single cells and spheroid outgrowth assays provided a quantitative measure of PTX-mediated radiosensitization. The PTX effect upon cells in low oxygen conditions was also studied in vitro after enzymatic oxygen scavenging. Results: Flow Cytometry: T98G cells exposed to both continuous and intermittent irradiation exhibit similar arrest at the G2/M checkpoint. The addition of 2 mM PTX significantly reduced the radiation-induced G2/M block in both irradiation schemes. Clonogenic Assays: The same PTX concentration applied before a continuous dose of 12 Gy, two intermittent doses of 6 Gy, or three intermittent doses of 4 Gy, all given within a 1-h interval, consistently caused radiosensitization. The drug enhancement ratios for PTX were 1.5, 2.7, and 6.0 for the continuous and two different intermittent dose schedules, respectively. Adding PTX after irradiation yielded lower enhancement ratios than pre-irradiation application. A similar pattern was observed after total doses of 4, 6, 9, or 12 Gy, as well. In low oxygen conditions, PTX was seen to have the same effects as in normoxic conditions. Spheroid Outgrowth Assays: The in vitro PTX

  20. Gamma Knife® radiosurgery for trigeminal neuralgia.

    Science.gov (United States)

    Yen, Chun-Po; Schlesinger, David; Sheehan, Jason P

    2011-11-01

    Trigeminal neuralgia is characterized by a temporary paroxysmal lancinating facial pain in the trigeminal nerve distribution. The prevalence is four to five per 100,000. Local pressure on nerve fibers from vascular loops results in painful afferent discharge from an injured segment of the fifth cranial nerve. Microvascular decompression addresses the underlying pathophysiology of the disease, making this treatment the gold standard for medically refractory trigeminal neuralgia. In patients who cannot tolerate a surgical procedure, those in whom a vascular etiology cannot be identified, or those unwilling to undergo an open surgery, stereotactic radiosurgery is an appropriate alternative. The majority of patients with typical facial pain will achieve relief following radiosurgical treatment. Long-term follow-up for recurrence as well as for radiation-induced complications is required in all patients undergoing stereotactic radiosurgery for trigeminal neuralgia.

  1. Physics of gamma knife approach on convergent beams in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Wu, A.; Lindner, G.; Maitz, A.H.; Kalend, A.M.; Lunsford, L.D.; Flickinger, J.C.; Bloomer, W.D.

    1990-01-01

    The Presbyterian-University Hospital of Pittsburgh installed the first clinically designated Leksell gamma knife in the U.S. in August 1987. Gamma knife radiosurgery involves stereotactic target localization with the Leksell frame and subsequent closed-skull single-treatment session irradiation of a lesion with multiple highly focused gamma ray beams produced from 60Co sources. The hemispherical array of sources, the large number of small-diameter beams, and the steep dose gradients surrounding a targeted lesion make physical characterization of the radiation field complex. This paper describes the physical features and the operation of the gamma knife as well as the calibration procedures of the very small, well-collimated beams. The results of studies using in-phantom ion chamber, diode, film, and lithium fluoride thermoluminescent dosimetry were all in close agreement. Both single-beam and multiple-beam dose profiles were measured and reported for the interchangeable helmets, which have 4-, 8-, 14-, and 18-mm-diameter collimators. We also describe the dose calculation and treatment planning algorithm in the treatment planning system. Measurements of the accuracy of mechanical and radiation alignment are also performed and discussed

  2. Radiosurgery in gliomas (middle-line tumors)

    International Nuclear Information System (INIS)

    Betti, O.O.; Rosler, R.

    1989-01-01

    The clinical experience is presented obtained from treatment with high-energy linac radiosurgery of 22 patients with stereotactically biopsed gliomas located in middle-line, from thalamus to brain stem and from infundibulum to pineo-tectal regions, during the period 1982-1987. (H.W.). 10 refs

  3. Linear accelerator stereotactic radiosurgery for vestibular schwannomas: a UK series.

    Science.gov (United States)

    Benghiat, H; Heyes, G; Nightingale, P; Hartley, A; Tiffany, M; Spooner, D; Geh, J I; Cruickshank, G; Irving, R M; Sanghera, P

    2014-06-01

    To evaluate non-auditory toxicity and local control after linear accelerator stereotactic radiosurgery (SRS) for the treatment of vestibular schwannomas. The institutional policy was to use SRS for radiologically progressing vestibular schwannomas. Case notes and plans were retrospectively reviewed for all patients undergoing SRS for vestibular schwannomas between September 2002 and June 2012. All patients were surgically immobilised using a BrainLab stereotactic head frame. The treatment plan was generated using BrainLab software (BrainScan 5.03). The aim was to deliver 12 Gy to the surface of the target with no margin. Patients with a minimum of 12 months of follow-up were included for toxicity and local control assessment. Radiological progression was defined as growth on imaging beyond 2 years of follow-up. Overall local control was defined in line with other series as absence of surgical salvage. Ninety-nine patients were identified. Two patients were lost to follow-up. After a median follow-up interval of 2.4 years, the actuarial radiological progression-free survival at 3 years was 100% and overall local control was also 100%. However, two patients progressed radiologically at 3.3 and 4.5 years, respectively. Twenty-one of 97 (22%) evaluable patients suffered trigeminal toxicity and this was persistent in 8/97 (8%). Two of 97 (2%) suffered long-term facial nerve toxicity (one with associated radiological progression causing hemi-facial spasm alone). One of 97 (1%) required intervention for obstructive hydrocephalus. No statistically significant dosimetric relationship could be shown to cause trigeminal or facial nerve toxicity. However, 7/8 patients with persistent trigeminal nerve toxicity had tumours in contact with the trigeminal nerve. SRS delivering 12 Gy using a linear accelerator leads to high local control rates, but only prospective evaluation will fully establish short-term toxicity. In this study, persistent trigeminal toxicity occurred almost

  4. Tolerance of cranial nerves of the cavernous sinus to radiosurgery

    International Nuclear Information System (INIS)

    Tishler, R.B.; Loeffler, J.S.; Alexander, E. III; Kooy, H.M.; Lunsford, L.D.; Duma, C.; Flickinger, J.C.

    1993-01-01

    Stereotactic radiosurgery is becoming a more accepted treatment option for benign, deep seated intracranial lesions. However, little is known about the effects of large single fractions of radiation on cranial nerves. This study was undertaken to assess the effect of radiosurgery on the cranial nerves of the cavernous sinus. The authors examined the tolerance of cranial nerves (II-VI) following radiosurgery for 62 patients (42/62 with meningiomas) treated for lesions within or near the cavernous sinus. Twenty-nine patients were treated with a modified 6 MV linear accelerator (Joint Center for Radiation Therapy) and 33 were treated with the Gamma Knife (University of Pittsburgh). Three-dimensional treatment plans were retrospectively reviewed and maximum doses were calculated for the cavernous sinus and the optic nerve and chiasm. Median follow-up was 19 months (range 3-49). New cranial neuropathies developed in 12 patients from 3-41 months following radiosurgery. Four of these complications involved injury to the optic system and 8 (3/8 transient) were the result of injury to the sensory or motor nerves of the cavernous sinus. There was no clear relationship between the maximum dose to the cavernous sinus and the development of complications for cranial nerves III-VI over the dose range used (1000-4000 cGy). For the optic apparatus, there was a significantly increased incidence of complications with dose. Four of 17 patients (24%) receiving greater than 800 cGy to any part of the optic apparatus developed visual complications compared with 0/35 who received less than 800 cGy (p = 0.009). Radiosurgery using tumor-controlling doses of up to 4000 cGy appears to be a relatively safe technique in treating lesions within or near the sensory and motor nerves (III-VI) of the cavernous sinus. The dose to the optic apparatus should be limited to under 800 cGy. 21 refs., 4 tabs

  5. State-of-the-art treatment alternatives for base of skull meningiomas: complementing and controversial indications for neurosurgery, stereotactic and robotic based radiosurgery or modern fractionated radiation techniques

    International Nuclear Information System (INIS)

    Combs, Stephanie E; Ganswindt, Ute; Foote, Robert L; Kondziolka, Douglas; Tonn, Jörg-Christian

    2012-01-01

    For skull base meningiomas, several treatment paradigms are available: Observation with serial imaging, surgical resection, stereotactic radiosurgery, radiation therapy or some combination of both. The choice depends on several factors. In this review we evaluate different treatment options, the outcome of modern irradiation techniques as well as the clinical results available, and establish recommendations for the treatment of patients with skull-base meningiomas

  6. Dose gradient analyses in linac-based intracranial stereotactic radiosurgery using paddick's gradient index. Consideration of the optimal method for plan evaluation

    International Nuclear Information System (INIS)

    Ohtakara, Kazuhiro; Hayashi, Shinya; Hoshi, Hiroaki

    2011-01-01

    The objective of our study was to describe the dose gradient characteristics of Linac-based stereotactic radiosurgery using Paddick's gradient index (GI) and to elucidate the factors influencing the GI value. Seventy-three plans for brain metastases using the dynamic conformal arcs were reviewed. The GI values were calculated at the 80% and 90% isodose surfaces (IDSs) and at the different target coverage IDSs (D99, D95, D90, and D85). The GI values significantly decreased as the target coverage of the reference IDS increased (the percentage of the IDS decreased). There was a significant inverse correlation between the GI values and target volume. The plans generated with the addition of a 1-mm leaf margin had worse GI values both at the D99 and D95 relative to those without leaf margin. The number and arrangement of arcs also affected the GI value. The GI values are highly sensitive to the IDS selection variability for dose prescription or evaluation, the target volume, and the planning method. To objectively compare the quality of dose gradient between rival plans, it would be preferable to employ the GI defined at the reference IDS indicating the specific target coverage (exempli gratia (e.g.), D95), irrespective of the intended marginal dose. The modified GI (mGI), defined in this study, substituting the denominator of the original GI with the target volume, would be useful to compensate for the false superior GI value in cases of target over-coverage with the reference IDS and to objectively evaluate the dose gradient outside the target boundary. (author)

  7. Dose linearity and monitor unit stability of a G4 type cyberknife robotic stereotactic radiosurgery system

    International Nuclear Information System (INIS)

    Sudahar, H.; Kurup, P.G.G.; Murali, V.; Velmurugan, J.

    2012-01-01

    Dose linearity studies on conventional linear accelerators show a linearity error at low monitor units (MUs). The purpose of this study was to establish the dose linearity and MU stability characteristics of a cyberknife (Accuracy Inc., USA) stereotactic radiosurgery system. Measurements were done at a depth of 5 cm in a stereotactic dose verification phantom with a source to surface distance of 75 cm in a Generation 4 (G4) type cyberknife system. All the 12 fixed-type collimators starting from 5 to 60 mm were used for the dose linearity study. The dose linearity was examined in small (1-10), medium (15-100) and large (125-1000) MU ranges. The MU stability test was performed with 60 mm collimator for 10 MU and 20 MU with different combinations. The maximum dose linearity error of -38.8% was observed for 1 MU with 5 mm collimator. Dose linearity error in the small MU range was considerably higher than in the medium and large MU ranges. The maximum error in the medium range was -2.4%. In the large MU range, the linearity error varied between -0.7% and 1.2%. The maximum deviation in the MU stability was -3.03%. (author)

  8. Implementation of a lung radiosurgery program: technical considerations and quality assurance in an Australian institution

    International Nuclear Information System (INIS)

    Siva, Shankar; MacManus, Michael; Ball, David; Chesson, Brent; Aarons, Yolanda; Clements, Natalie; Kron, Tomas

    2012-01-01

    The Peter MacCallum Cancer Centre has established a stereotactic lung radiosurgery program for the treatment of isolated lung metastases. The aim of this study was to critically assess the technical feasibility of performing stereotactic lung radiosurgery in an Australian institution. A single 26-Gy fraction of radiotherapy was delivered to patients with positron emission tomography (PET) staged solitary lung metastases. Motion management was addressed using four-dimensional computed tomographic simulation, and cone beam CT (CBCT) online soft-tissue matching. Treatments were with multiple coplanar and non-coplanar asymmetric beams. Patients were immobilised in a dedicated stereotactic body cradle. Quality assurance (QA) of treatment plans with both ion chamber and film measurements was performed accounting for patient-specific respiratory motion. Between February 2010 and February 2011, nine patients received stereotactic lung radiosurgery. One grade 1 toxicity and one grade 2 toxicity were recorded after treatment. The mean planning target volume was 22.6 cc. A median of eight beams were delivered per treatment plan (range 7–10) with a median of two non-coplanar beams (range 0–6). At treatment plan QA, the difference between planned and delivered dose was ≤1.76% in all static and dynamic ion chamber recordings. A mid-treatment CBCT was performed at a median time of 21 min, with the mean displacement discrepancy from initial set-up being 0.4 mm (range 0–2 mm). Stereotactic radiosurgery to the lung was both feasible and tolerable at our institution. Intrafractional immobilisation within 2 mm was reproducible. Excellent concordance between planned and delivered treatments was achieved in the phantom QA.

  9. Radiosurgery for pituitary adenomas

    International Nuclear Information System (INIS)

    Castro, Douglas Guedes de; Salvajoli, Joao Victor; Canteras, Miguel Montes; Cecilio, Soraya A. Jorge

    2006-01-01

    Pituitary adenomas represent nearly 15% of all intracranial tumors. Multimodal treatment includes microsurgery, medical management and radiotherapy. Microsurgery is the primary recommendation for nonfunctioning and most of functioning adenomas, except for prolactinomas that are usually managed with dopamine agonist drugs. However, about 30% of patients require additional treatment after microsurgery for recurrent or residual tumors. In these cases, fractionated radiation therapy has been the traditional treatment. More recently, radiosurgery has been established as a treatment option. Radiosurgery allows the delivery of prescribed dose with high precision strictly to the target and spares the surrounding tissues. Therefore, the risks of hypopituitarism, visual damage and vasculopathy are significantly lower. Furthermore, the latency of the radiation response after radiosurgery is substantially shorter than that of fractionated radiotherapy. The goal of this review is to define the efficacy, safety and role of radiosurgery for treatment of pituitary adenomas and to present the preliminary results of our institution. (author)

  10. Toxicity of Gamma Knife Radiosurgery in the Treatment of Intracranial Tumors in Patients With Collagen Vascular Diseases or Multiple Sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Lowell, Dot [Department of Radiation Oncology, School of Medicine, Wake Forest University, Winston-Salem, NC (United States); Tatter, Stephen B. [Department of Neurosurgery, School of Medicine, Wake Forest University, Winston-Salem, NC (United States); Bourland, J. Daniel; Guzman, Allan F. de; Ekstrand, Kenneth E. [Department of Radiation Oncology, School of Medicine, Wake Forest University, Winston-Salem, NC (United States); Ellis, Thomas L. [Department of Neurosurgery, School of Medicine, Wake Forest University, Winston-Salem, NC (United States); Lovato, James F. [Division of Public Health Sciences, School of Medicine, Wake Forest University, Winston-Salem, NC (United States); McMullen, Kevin P.; Munley, Michael T.; Shaw, Edward G.; Urbanic, James J. [Department of Radiation Oncology, School of Medicine, Wake Forest University, Winston-Salem, NC (United States); Chan, Michael D., E-mail: mchan@wfubmc.edu [Department of Radiation Oncology, School of Medicine, Wake Forest University, Winston-Salem, NC (United States)

    2011-11-15

    Purpose: To assess toxicity in patients with either a collagen vascular disease (CVD) or multiple sclerosis (MS) treated with intracranial radiosurgery. Methods and Materials: Between January 2004 and April 2009, 6 patients with MS and 14 patients with a CVD were treated with Gamma Knife radiosurgery (GKRS) for intracranial tumors. Treated lesions included 15 total brain metastases in 7 patients, 11 benign brain tumors, 1 low grade glioma, and 1 cavernous malformation. Toxicities were graded by the Radiation Therapy Oncology Group Acute/Late Radiation Morbidity Scoring Criteria. 'Rare toxicities' were characterized as those reported in the scientific literature at an incidence of <5%. Results: Median follow-up time was 16 months. Median dose to the tumor margin was 13.0 Gy (range, 12-21 Gy). Median size of tumor was 5.0 cm{sup 3} (range, 0.14-7.8 cm{sup 3}). Of the 14 patients with CVD, none experienced a Grade 3 or 4 toxicity or a toxicity characterized as rare. Of the 6 patients with MS, 3 experienced rare toxicities, and two of these were Grade 3 toxicities. Rare complications included a patient experiencing both communicating hydrocephalus and facial nerve palsy, as well as 2 additional patients with motor cranial nerve palsy. High-grade toxicities included the patient with an acoustic neuroma requiring ventriculoperitoneal shunt placement for obstructive hydrocephalus, and 1 patient with a facial nerve schwannoma who experienced permanent facial nerve palsy. Interval between radiosurgery and high-grade toxicities ranged from 1 week to 4 months. Conclusions: Our series suggests that patients with MS who receive GKRS may be at increased risk of rare and high-grade treatment-related toxicity. Given the time course of toxicity, treatment-related edema or demyelination represent potential mechanisms.

  11. Stereotactic Radiosurgery for Recurrent or Unresectable Pilocytic Astrocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Hallemeier, Christopher L. [Department of Radiation Oncology, Mayo Clinic, Rochester, MN (United States); Pollock, Bruce E. [Department of Radiation Oncology, Mayo Clinic, Rochester, MN (United States); Department of Neurological Surgery, Mayo Clinic, Rochester, MN (United States); Schomberg, Paula J. [Department of Radiation Oncology, Mayo Clinic, Rochester, MN (United States); Link, Michael J. [Department of Neurological Surgery, Mayo Clinic, Rochester, MN (United States); Brown, Paul D. [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Stafford, Scott L., E-mail: Stafford.scott@mayo.edu [Department of Radiation Oncology, Mayo Clinic, Rochester, MN (United States)

    2012-05-01

    Purpose: To report the outcomes in patients with recurrent or unresectable pilocytic astrocytoma (PA) treated with Gamma Knife stereotactic radiosurgery (SRS). Methods and Materials: Retrospective review of 18 patients (20 lesions) with biopsy-confirmed PA having SRS at our institution from 1992 through 2005. Results: The median patient age at SRS was 23 years (range, 4-56). Thirteen patients (72%) had undergone one or more previous surgical resections, and 10 (56%) had previously received external-beam radiation therapy (EBRT). The median SRS treatment volume was 9.1 cm{sup 3} (range, 0.7-26.7). The median tumor margin dose was 15 Gy (range, 12-20). The median follow-up was 8.0 years (range, 0.5-15). Overall survival at 1, 5, and 10 years after SRS was 94%, 71%, and 71%, respectively. Tumor progression (local solid progression, n = 4; local solid progression + distant, n = 1; distant, n = 2; cyst development/progression, n = 4) was noted in 11 patients (61%). Progression-free survival at 1, 5, and 10 years was 65%, 41%, and 17%, respectively. Prior EBRT was associated with inferior overall survival (5-year risk, 100% vs. 50%, p = 0.03) and progression-free survival (5-year risk, 71% vs. 20%, p = 0.008). Nine of 11 patients with tumor-related symptoms improved after SRS. Symptomatic edema after SRS occurred in 8 patients (44%), which resolved with short-term corticosteroid therapy in the majority of those without early disease progression. Conclusions: SRS has low permanent radiation-related morbidity and durable local tumor control, making it a meaningful treatment option for patients with recurrent or unresectable PA in whom surgery and/or EBRT has failed.

  12. Stereotactic Radiosurgery for Recurrent or Unresectable Pilocytic Astrocytoma

    International Nuclear Information System (INIS)

    Hallemeier, Christopher L.; Pollock, Bruce E.; Schomberg, Paula J.; Link, Michael J.; Brown, Paul D.; Stafford, Scott L.

    2012-01-01

    Purpose: To report the outcomes in patients with recurrent or unresectable pilocytic astrocytoma (PA) treated with Gamma Knife stereotactic radiosurgery (SRS). Methods and Materials: Retrospective review of 18 patients (20 lesions) with biopsy-confirmed PA having SRS at our institution from 1992 through 2005. Results: The median patient age at SRS was 23 years (range, 4–56). Thirteen patients (72%) had undergone one or more previous surgical resections, and 10 (56%) had previously received external-beam radiation therapy (EBRT). The median SRS treatment volume was 9.1 cm 3 (range, 0.7–26.7). The median tumor margin dose was 15 Gy (range, 12–20). The median follow-up was 8.0 years (range, 0.5–15). Overall survival at 1, 5, and 10 years after SRS was 94%, 71%, and 71%, respectively. Tumor progression (local solid progression, n = 4; local solid progression + distant, n = 1; distant, n = 2; cyst development/progression, n = 4) was noted in 11 patients (61%). Progression-free survival at 1, 5, and 10 years was 65%, 41%, and 17%, respectively. Prior EBRT was associated with inferior overall survival (5-year risk, 100% vs. 50%, p = 0.03) and progression-free survival (5-year risk, 71% vs. 20%, p = 0.008). Nine of 11 patients with tumor-related symptoms improved after SRS. Symptomatic edema after SRS occurred in 8 patients (44%), which resolved with short-term corticosteroid therapy in the majority of those without early disease progression. Conclusions: SRS has low permanent radiation-related morbidity and durable local tumor control, making it a meaningful treatment option for patients with recurrent or unresectable PA in whom surgery and/or EBRT has failed.

  13. Multi-staged robotic stereotactic radiosurgery for large cerebral arteriovenous malformations

    International Nuclear Information System (INIS)

    Ding, Chuxiong; Solberg, Timothy D.; Hrycushko, Brian; Medin, Paul; Whitworth, Louis; Timmerman, Robert D.

    2013-01-01

    Purpose: To investigate a multi-staged robotic stereotactic radiosurgery (SRS) delivery technique for the treatment of large cerebral arteriovenous malformations (AVMs). The treatment planning process and strategies to optimize both individual and composite dosimetry are discussed. Methods: Eleven patients with large (30.7 ± 19.2 cm 3 ) AVMs were selected for this study. A fiducial system was designed for fusion of targets between planar angiograms and simulation CT scans. AVMs were contoured based on single contrast CT, MRI and orthogonal angiogram images. AVMs were divided into 3–8 sub-target volumes (3–7 cm 3 ) for sequential treatment at 1–4 week intervals to a prescription dose of 16–20 Gy. Forward and inversely developed treatment plans were optimized for 95% coverage of the total AVM volume by dose summation from each sub-volume, while minimizing dose to surrounding tissues. Dose-volume analysis was used to evaluate the PTV coverage, dose conformality (CI), and R 50 and V 12Gy parameters. Results: The treatment workflow was commissioned and able to localize within 1 mm. Inverse optimization outperformed forward planning for most patients for each index considered. Dose conformality was shown comparable to staged Gamma Knife treatments. Conclusion: The CyberKnife system is shown to be a practical delivery platform for multi-staged treatments of large AVMs using forward or inverse planning techniques

  14. Dosimetric verification of stereotactic radiosurgery/stereotactic radiotherapy dose distributions using Gafchromic EBT3

    Energy Technology Data Exchange (ETDEWEB)

    Cusumano, Davide, E-mail: davide.cusumano@unimi.it [School of Medical Physics, University of Milan, Milan (Italy); Fumagalli, Maria L. [Health Department, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan (Italy); Marchetti, Marcello; Fariselli, Laura [Department of Neurosurgery, Radiotherapy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan (Italy); De Martin, Elena [Health Department, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan (Italy)

    2015-10-01

    Aim of this study is to examine the feasibility of using the new Gafchromic EBT3 film in a high-dose stereotactic radiosurgery and radiotherapy quality assurance procedure. Owing to the reduced dimensions of the involved lesions, the feasibility of scanning plan verification films on the scanner plate area with the best uniformity rather than using a correction mask was evaluated. For this purpose, signal values dispersion and reproducibility of film scans were investigated. Uniformity was then quantified in the selected area and was found to be within 1.5% for doses up to 8 Gy. A high-dose threshold level for analyses using this procedure was established evaluating the sensitivity of the irradiated films. Sensitivity was found to be of the order of centiGray for doses up to 6.2 Gy and decreasing for higher doses. The obtained results were used to implement a procedure comparing dose distributions delivered with a CyberKnife system to planned ones. The procedure was validated through single beam irradiation on a Gafchromic film. The agreement between dose distributions was then evaluated for 13 patients (brain lesions, 5 Gy/die prescription isodose ~80%) using gamma analysis. Results obtained using Gamma test criteria of 5%/1 mm show a pass rate of 94.3%. Gamma frequency parameters calculation for EBT3 films showed to strongly depend on subtraction of unexposed film pixel values from irradiated ones. In the framework of the described dosimetric procedure, EBT3 films proved to be effective in the verification of high doses delivered to lesions with complex shapes and adjacent to organs at risk.

  15. Treatment of acoustic neuroma: stereotactic radiosurgery vs. microsurgery

    International Nuclear Information System (INIS)

    Karpinos, Marianna; Teh, Bin S.; Zeck, Otto; Carpenter, L. Steven; Phan, Chris; Mai, W.-Y.; Lu, Hsin H.; Chiu, J. Kam; Butler, E. Brian; Gormley, William B.; Woo, Shiao Y.

    2002-01-01

    Purpose: Two major treatment options are available for patients with acoustic neuroma, microsurgery and radiosurgery. Our objective was to compare these two treatment modalities with respect to tumor growth control, hearing preservation, development of cranial neuropathies, complications, functional outcome, and patient satisfaction. Methods and Materials: To compare radiosurgery with microsurgery, we analyzed 96 patients with unilateral acoustic neuromas treated with Leksell Gamma Knife or microsurgery at Memorial Hermann Hospital, Houston, Texas, between 1993 and 2000. Radiosurgery technique involved multiple isocenter (1-30 single fraction fixed-frame magnetic resonance imaging) image-based treatment with a mean dose prescription of 14.5 Gy. Microsurgery included translabyrinthine, suboccipital, and middle fossa approaches with intraoperative neurophysiologic monitoring. Preoperative patient characteristics were similar except for tumor size and age. Patients undergoing microsurgery were younger with larger tumors compared to the radiosurgical group. The tumors were divided into small 4.0 cm. Median follow-up of the radiosurgical group was longer than the microsurgical group, 48 months (3-84 months) vs. 24 months (3-72 months). Results: There was no statistical significance in tumor growth control between the two groups, 100% in the microsurgery group vs. 91% in the radiosurgery group (p>0.05). Radiosurgery was more effective than microsurgery in measurable hearing preservation, 57.5% vs. 14.4% (p=0.01). There was no difference in serviceable hearing preservation between the two groups. Microsurgery was associated with a greater rate of facial and trigeminal neuropathy in the immediate postoperative period and at long-term follow-up. The rate of development of facial neuropathy was significantly higher in the microsurgical group than in the radiosurgical group (35% vs. 0%, p<0.01 in the immediate postsurgical period and 35.3% vs. 6.1%, p=0.008, at long

  16. Treatment of acoustic neuroma: stereotactic radiosurgery vs. microsurgery

    Energy Technology Data Exchange (ETDEWEB)

    Karpinos, Marianna; Teh, Bin S; Zeck, Otto; Carpenter, L Steven; Phan, Chris; Mai, W -Y; Lu, Hsin H; Chiu, J Kam; Butler, E Brian; Gormley, William B; Woo, Shiao Y

    2002-12-01

    Purpose: Two major treatment options are available for patients with acoustic neuroma, microsurgery and radiosurgery. Our objective was to compare these two treatment modalities with respect to tumor growth control, hearing preservation, development of cranial neuropathies, complications, functional outcome, and patient satisfaction. Methods and Materials: To compare radiosurgery with microsurgery, we analyzed 96 patients with unilateral acoustic neuromas treated with Leksell Gamma Knife or microsurgery at Memorial Hermann Hospital, Houston, Texas, between 1993 and 2000. Radiosurgery technique involved multiple isocenter (1-30 single fraction fixed-frame magnetic resonance imaging) image-based treatment with a mean dose prescription of 14.5 Gy. Microsurgery included translabyrinthine, suboccipital, and middle fossa approaches with intraoperative neurophysiologic monitoring. Preoperative patient characteristics were similar except for tumor size and age. Patients undergoing microsurgery were younger with larger tumors compared to the radiosurgical group. The tumors were divided into small <2.0 cm, medium 2.0-3.9 cm, or large >4.0 cm. Median follow-up of the radiosurgical group was longer than the microsurgical group, 48 months (3-84 months) vs. 24 months (3-72 months). Results: There was no statistical significance in tumor growth control between the two groups, 100% in the microsurgery group vs. 91% in the radiosurgery group (p>0.05). Radiosurgery was more effective than microsurgery in measurable hearing preservation, 57.5% vs. 14.4% (p=0.01). There was no difference in serviceable hearing preservation between the two groups. Microsurgery was associated with a greater rate of facial and trigeminal neuropathy in the immediate postoperative period and at long-term follow-up. The rate of development of facial neuropathy was significantly higher in the microsurgical group than in the radiosurgical group (35% vs. 0%, p<0.01 in the immediate postsurgical period and 35

  17. Dosimetric measurements of Onyx embolization material for stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Roberts, Donald A.; Balter, James M.; Chaudhary, Neeraj; Gemmete, Joseph J.; Pandey, Aditya S.

    2012-01-01

    Purpose: Arteriovenous malformations are often treated with a combination of embolization and stereotactic radiosurgery. Concern has been expressed in the past regarding the dosimetric properties of materials used in embolization and the effects that the introduction of these materials into the brain may have on the quality of the radiosurgery plan. To quantify these effects, the authors have taken large volumes of Onyx 34 and Onyx 18 (ethylene-vinyl alcohol copolymer doped with tantalum) and measured the attenuation and interface effects of these embolization materials. Methods: The manufacturer provided large cured volumes (∼28 cc) of both Onyx materials. These samples were 8.5 cm in diameter with a nominal thickness of 5 mm. The samples were placed on a block tray above a stack of solid water with an Attix chamber at a depth of 5 cm within the stack. The Attix chamber was used to measure the attenuation. These measurements were made for both 6 and 16 MV beams. Placing the sample directly on the solid water stack and varying the thickness of solid water between the sample and the Attix chamber measured the interface effects. The computed tomography (CT) numbers for bulk material were measured in a phantom using a wide bore CT scanner. Results: The transmission through the Onyx materials relative to solid water was approximately 98% and 97% for 16 and 6 MV beams, respectively. The interface effect shows an enhancement of approximately 2% and 1% downstream for 16 and 6 MV beams. CT numbers of approximately 2600–3000 were measured for both materials, which corresponded to an apparent relative electron density (RED) ρ e w to water of approximately 2.7–2.9 if calculated from the commissioning data of the CT scanner. Conclusions: We performed direct measurements of attenuation and interface effects of Onyx 34 and Onyx 18 embolization materials with large samples. The introduction of embolization materials affects the dose distribution of a MV therapeutic beam

  18. Awake craniotomy for excision of arteriovenous malformations? A qualitative comparison study with stereotactic radiosurgery.

    Science.gov (United States)

    Chan, David Yuen Chung; Chan, Danny Tat Ming; Zhu, Cannon Xian Lun; Kan, Patricia Kwok Yee; Ng, Amelia Yikjin; Hsieh, Yi-Pin Sonia; Abrigo, Jill; Poon, Wai Sang; Wong, George Kwok Chu

    2018-05-01

    Treatment of arteriovenous malformations (AVM) located at the eloquent area has been a challenge. Awake brain mapping allows identification of a non-eloquent gyrus for intervention and can potentially facilitate resection with preservation of functions. An alternative treatment option is stereotactic radiosurgery (SRS). The objective of this study was to perform a qualitative comparison of the treatment outcome of awake AVM excision versus SRS. We conducted a 13-year retrospective review of AVM excision under awake craniotomy performed at Prince of Wales Hospital, Hong Kong, from 2003 to 2016. Patients' presentation, Spetzler-Martin (SM) grading, rate of obliteration and complication were reviewed and analyzed with the modified radiosurgery-based AVM score (RS score). Six patients had excision of AVM under awake mapping during this period of time. Two were SM Grade II and four were SM Grade III. Five located at the peri-rolandic region while one at the temporal language area. None had failed mapping. Five out of six achieved complete obliteration (83.3%). Qualitative comparative analysis had revealed better treatment outcome with awake AVM excision as compared to SRS with the obliteration rate of 100% versus 96% for RS score ≤1.00, 100% versus 78% for RS score 1.01-1.50, and 66% versus 50% for RS score >2.00 respectively. In conclusion, awake mapping and excision of AVMs at the eloquent area is feasible. Qualitative comparative analysis had revealed higher obliteration rate with awake AVM excision as compared to SRS. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Clinical Experiences With Onboard Imager KV Images for Linear Accelerator-Based Stereotactic Radiosurgery and Radiotherapy Setup

    International Nuclear Information System (INIS)

    Hong, Linda X.; Chen, Chin C.; Garg, Madhur; Yaparpalvi, Ravindra; Mah, Dennis

    2009-01-01

    Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after treatment for 21 SRS patients and on a weekly basis for 6 SRT patients to assess any intrafraction changes. Results: For SRS patients, 57 pretreatment kV images were evaluated and the suggested shifts were all within 1 mm in any direction (i.e., within the accuracy of image fusion). For SRT patients, the suggested shifts were out of the 3-mm tolerance for 31 of 309 setups. Intrafraction motions were detected in 3 SRT patients. Conclusions: kV imaging provided a useful tool for SRS or SRT setups. For SRS setup with head frame, it provides radiographic confirmation of localization using the stereotactic target positioner. For SRT with mask, a 3-mm margin is adequate and feasible for routine setup when TaPo is combined with kV imaging

  20. Stereotactic radiotherapy for brain metastasis

    International Nuclear Information System (INIS)

    Noel, G.; Daisne, J.F.; Thillays, F.

    2012-01-01

    Stereotactic radiosurgery is now well implanted in the radiotherapy treatment tools of brain metastasis. The dose can be delivered in one or multiple sessions. Results seem equivalent. CT scan and MRI imaging are required to delineate and calculate dosimetry. Doses are variable according to the size of the metastases, localization, pathology or equipment. Stabilization or reduction of tumour size is the rules after stereotactic treatment. Impact in terms of overall survival is more difficult to apprehend because of the general context of the disease. Many questions remain unresolved, such as the usefulness of whole brain irradiation, adaptation of the treatment schedule to tumour pathophysiology, role of stereotactic treatment after surgery of metastases, etc. (authors)

  1. Stereotactic lesioning for mental illness

    International Nuclear Information System (INIS)

    Kim, M.-C.; Lee, T.-K.

    2008-01-01

    The authors report stereotactically created lesioning by radiofrequency or Cyberknife radiosurgery for patients with mental illness. Since 1993, thirty-eight patients have undergone stereotactic psychosurgery for medically intractable mental illnesses. Two patients had aggressive behavior. Twenty-five patients suffered from Obsessive-Compulsive Disorder (OCD) and ten patients had depression. Another patient suffered from atypical psychosis. Bilateral amygdalotomy and subcaudate tractotomy were done for aggressive behavior. Limbic leucotomy or anterior cingulotomy was done for CCD and subcaudate tractotomy with or without cingulotomy was done for depression. In twenty-three patients, the lesions were made by a radiofrequency (RF) lesion generator. In fifteen cases, the lesions were made with Cyberknife Radiosurgery (CKRS). The Overt Aggression Scale (OAS) declined from 8 to 2 with clinical improvement during follow up period. With long-term follow up (meaning 57 months) in 25 OCDs, the mean Yale Brown Obsessive Compulsive Score (YBOCS) declined from 34 to 13 (n = 25). The Hamilton Depression scale (HAMD) for ten patients with depression declined from 38.5 to 10.5 (n = 10). There was no operative mortality and no significant morbidity except one case with transient urinary incontinence. Authors suggest that stereotactic psychosurgery by RF and CKRS could be a safe and effective means of treating some medically intractable mental illnesses. (author)

  2. Emerging technologies in stereotactic body radiotherapy.

    Science.gov (United States)

    Ma, Lijun; Wang, Lei; Tseng, Chia-Lin; Sahgal, Arjun

    2017-09-01

    Stereotactic body radiation therapy (SBRT) stems from the initial developments of intra-cranial stereotactic radiosurgery (SRS). Despite similarity in their names and clinical goals of delivering a sufficiently high tumoricidal dose, maximal sparing of the surrounding normal tissues and a short treatment course, SBRT technologies have transformed from the early days of body frame-based treatments with X-ray verification to primarily image-guided procedures with cone-beam CT or stereoscopic X-ray systems and non-rigid body immo-bilization. As a result of the incorporation of image-guidance systems and multi-leaf col-limators into mainstream linac systems, and treatment planning systems that have also evolved to allow for routine dose calculations to permit intensity modulated radiotherapy and volumetric modulated arc therapy (VMAT), SBRT has disseminated rapidly in the community to manage many disease sites that include oligometastases, spine lesions, lung, prostate, liver, renal cell, pelvic tumors, and head and neck tumors etc. In this article, we review the physical principles and paradigms that led to the widespread adoption of SBRT practice as well as technical caveats specific to individual SBRT technologies. From the perspective of treatment delivery, we categorically described (I) C-arm linac-based SBRT technologies; (II) robotically manipulated X-band CyberKnife® technology; and (III) emerging specialized systems for SBRT that include integrated MRI-linear accelerators and the imaged-guided Gamma Knife Perfexion Icon system with expanded multi-isocenter treatments of skull-based tumors, head-and-neck and cervical-spine lesions.

  3. Intensity-modulated stereotactic radiosurgery using dynamic micro-multileaf collimation

    International Nuclear Information System (INIS)

    Benedict, Stanley H.; Cardinale, Robert M.; Wu Qiuwen; Zwicker, Robert D.; Broaddus, William C.; Mohan, Radhe

    2001-01-01

    Purpose: The implementation of dynamic leaf motion on a micro-multileaf collimator system provides the capability for intensity-modulated stereotactic radiosurgery (IMSRS), and the consequent potential for improved dose distributions for irregularly shaped tumor volumes adjacent to critical organs. This study explores the use of IMSRS to provide improved tumor coverage and normal tissue sparing for small cranial tumors relative to plans based on multiple fixed uniform-intensity beams or traditional circular collimator arc-based stereotactic techniques. Methods and Materials: Four patient cases involving small brain lesions are presented and analyzed. The cases were chosen to include a representative selection of target shapes, number of targets, and adjacent critical areas. Patient plans generated for these comparisons include standard arcs with multiple circular collimators, and fixed noncoplanar static fields with uniform-intensity beams and IMSRS. Parameters used for evaluation of the plans include the percentage of irradiated volume to tumor volume (PITV), normal tissue dose-volume histograms, and dose-homogeneity ratios. All IMSRS plans were computed using previously established IMRT techniques adapted for use with the BrainLAB M3 micro-multileaf collimator. The algorithms comprising the IMRT system for optimization of intensity distributions and conversion into leaf trajectories of the BrainLab M3 were developed at our institution. The ADAC Pinnacle 3 radiation treatment-planning system was used for dose calculations and for input of contours for target volumes and normal critical structures. Results: For all cases, the IMSRS plans showed a high degree of conformity of the dose distribution with the target shape. The IMSRS plans provided either (1) a smaller volume of normal tissue irradiated to significant dose levels, generally taken as doses greater than 50% of the prescription, or (2) a lower dose to an important adjacent critical organ. The reduction in

  4. Contribution to the planning and dosimetry of photon beams applied to radiosurgery and stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Santos, Walter Menezes

    2003-08-01

    Radiosurgery and stereotactic radiotherapy are irradiation techniques that use small diameter photon beams for treating intracranial lesions such as pituitary adenomas, acoustic tumors and arterio-venous malformations which are inaccessible for surgery. These treatment techniques are characterized by the use of very small radiation beams which deliver a precisely measured dose to the target volume, while sparing the surrounding healthy tissue. Treatment can be performed by using multiple 60 Co gamma-ray sources (in the so-called 'Gamma Knife'), charged particles or X-ray beams produced by linear accelerators. The prescribed dose can be given in a single session or in multiple fractions, as in conventional radiotherapy. The success of the treatment depends, among other factors, of the accurate determination of the parameters that characterize the radiation beam produced by the equipment, as well as, of a well designed quality assurance program. In this study, the dosimetric parameters of a set of collimating cones of a Radionics TM treatment system applied to two 6 MV- photon beams (Clinac 600C - Varian TM , and Mevatron MD2 - Siemens TM ) were evaluated by using a water filled PMMA simulator. Measurements were carried out for photon beam diameters ranging from 12.5 to 40.0 mm for the Clinac-600C and from 5.0 to 50.0 mm for the Mevatron MD2. The parameters were evaluated by using a parallel plate ionization chamber (Markus), Kodak X-Omat V dosimetric films, thermoluminescent dosemeters (Harschaw, TLD-100) and photodiodes. The maximum tissue-ratio, the off-axis profile and the output factors were determined and the results were compared to those reported elsewhere. A study of the dosimetric characteristics of some commercially available phototransistors was also carried out. The results showed that these electronic components can be successfully used for measuring the dosimetric parameters of small diameter photon beans used in radiosurgery. Measurements were also

  5. Stereotactic radiosurgery for brain metastasis: Pitie-Salpetriere Hospital experience

    International Nuclear Information System (INIS)

    Feuvret, L.; Germain, I.; Cornu, P.; Boisserie, G.; Dormont, D.; Hardiman, C.; Tep, B.; Faillot, T.; Duffau, H.; Simon, J.M.; Dendale, R.; Delattre, J.Y.; Poisson, M.; Marsault, C.; Philippon, J.; Fohanno, D.; Baillet, F.; Mazeron, J.J.

    1998-01-01

    Retrospective analysis of the influence of clinical and technical factors on local control and survival after radiosurgery for brain metastasis. From january 1994 to December 1996, 42 patients presenting with 71 metastases underwent radiosurgery for brain metastasis. The median age was 56 years and the median Karnofsky index 80. Primary sites included: lung (20 patients), kidney (seven), breast (five), colon (two), melanoma (three), osteosarcoma (one) and it was unknown for three patients. Seventeen patients had extracranial metastasis. Twenty-four patients were treated at recurrence which occurred after whole brain irradiation (12 patients), surgical excision (four) or after both treatments (eight). Thirty-six sessions of radiosurgery have been realized for one metastasis and 13 for two, three or four lesions. The median metastasis diameter was 21 mm and the median volume 1.7 cm 3 . The median peripheral dose to the lesion was 14 Gy, and the median dose at the isocenter 20 Gy. Sixty-five metastasis were evaluable for response analysis. The overall local control rate was 82% and the 1-year actuarial rate was 72%. In univariate analysis, theoretical radioresistance (P = 0.001), diameter less than 3 cm (P = 0.039) and initial treatment with radiosurgery (P 0.041) were significantly associated with increased local control. Only the first two factors remained significant in multivariate analysis. No prognostic factor of overall survival was identified. The median survival was 12 months. Six patients had a symptomatic oedema (RTOG grade 2), only one of which requiring a surgical excision. In conclusion, 14 Gy delivered at the periphery of metastasis seems to be a sufficient dose to control most brain metastases, with a minimal toxicity. Better results were obtained for lesions initially treated with radiosurgery, theoretically radioresistant and with a diameter less than 3 cm. (authors)

  6. Radiosurgery for acoustic neurinomas: Early experience

    International Nuclear Information System (INIS)

    Linskey, M.E.; Lunsford, L.D.; Flickinger, J.C.

    1990-01-01

    We reviewed our early experience with the first 26 patients with acoustic neurinomas (21 unilateral, 5 bilateral) treated by stereotactic radiosurgery using the first North American 201-source cobalt-60 gamma knife. Follow-up ranged from 6 to 19 months (median, 13 months). Serial postoperative imaging showed either a decrease in tumor size (11 patients) or growth arrest (15 patients). Loss of central contrast enhancement was a characteristic change (18 patients). Seven patients had good or serviceable hearing preoperatively. In all 7 the preoperative hearing status was retained immediately after radiosurgery. At follow-up, 3 had preserved hearing, 1 had reduced hearing, and 3 had lost all hearing in the treated ear. Hearing in 1 patient that was nonserviceable preoperatively later improved to a serviceable hearing level. Delayed facial paresis developed in 6 patients, and delayed trigeminal sensory loss developed in 7 patients, none of whom had significant deficits before radiosurgery. Both facial and trigeminal deficits tended to improve within 3 to 6 months of onset with excellent recovery anticipated. Lower cranial nerve dysfunction was not observed. All 26 patients remain at their preoperative employment or functional status. At present, stereotactic radiosurgery is an alternative treatment for acoustic neurinomas in patients who are elderly, have significant concomitant medical problems, have a tumor in their only hearing ear, have bilateral acoustic neurinomas, refuse microsurgical excision, or have recurrent tumor despite surgical resection. Although longer and more extensive follow-up is required, the control of tumor growth and the acceptable rate of complications in this early experience testifies to the future expanding role of this technique in the management of selected acoustic neurinomas

  7. Multileaf collimator-based linear accelerator radiosurgery: five-year efficiency analysis.

    Science.gov (United States)

    Lawson, Joshua D; Fox, Tim; Waller, Anthony F; Davis, Lawrence; Crocker, Ian

    2009-03-01

    In 1989, Emory University initiated a linear accelerator (linac) radiosurgery program using circular collimators. In 2001, the program converted to a multileaf collimator. Since then, the treatment parameters of each patient have been stored in the record-and-verify system. Three major changes have occurred in the radiosurgery program in the past 6 years: in 2002, treatment was changed from static conformal beams to dynamic conformal arc (DCA) therapy, and all patients were imaged before treatment. Beginning in 2005, a linac was used, with the opportunity to treat at higher dose rates (600-1,000 monitor units/min). The aim of this study was to analyze the time required to deliver radiosurgery and the factors affecting treatment delivery. Benchmark data are provided for centers contemplating initiating linac radiosurgery programs. Custom software was developed to mine the record-and-verify system database and automatically perform a chart review on patients who underwent stereotactic radiosurgery from March 2001 to October 2006. The software extracted 510 patients who underwent stereotactic radiosurgery, and the following information was recorded for each patient: treatment technique, treatment time (from initiation of imaging, if done, to completion of therapy), number of isocenters, number of fields, total monitor units, and dose rate. Of the 510 patients, 395 were treated with DCA therapy and 115 with static conformal beams. The average number of isocenters treated was 1.06 (range, 1-4). The average times to deliver treatment were 24.1 minutes for patients who underwent DCA therapy and 19.3 minutes for those treated with static conformal beams, reflecting the lack of imaging in the latter patients. Eighty percent of patients were treated in question the need for a dedicated radiosurgery unit for even busy treatment centers.

  8. Outcomes of Diffusion Tensor Tractography-Integrated Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Tomoyuki, E-mail: kouga-tky@umin.ac.jp [Department of Neurosurgery, University of Tokyo Hospital, Tokyo (Japan); Maruyama, Keisuke; Kamada, Kyousuke; Ota, Takahiro; Shin, Masahiro [Department of Neurosurgery, University of Tokyo Hospital, Tokyo (Japan); Itoh, Daisuke [Department of Radiology, University of Tokyo Hospital, Tokyo (Japan); Kunii, Naoto [Department of Neurosurgery, University of Tokyo Hospital, Tokyo (Japan); Ino, Kenji; Terahara, Atsuro; Aoki, Shigeki; Masutani, Yoshitaka [Department of Radiology, University of Tokyo Hospital, Tokyo (Japan); Saito, Nobuhito [Department of Neurosurgery, University of Tokyo Hospital, Tokyo (Japan)

    2012-02-01

    Purpose: To analyze the effect of use of tractography of the critical brain white matter fibers created from diffusion tensor magnetic resonance imaging on reduction of morbidity associated with radiosurgery. Methods and Materials: Tractography of the pyramidal tract has been integrated since February 2004 if lesions are adjacent to it, the optic radiation since May 2006, and the arcuate fasciculus since October 2007. By visually confirming the precise location of these fibers, the dose to these fiber tracts was optimized. One hundred forty-four consecutive patients with cerebral arteriovenous malformations who underwent radiosurgery with this technique between February 2004 and December 2009 were analyzed. Results: Tractography was prospectively integrated in 71 of 155 treatments for 144 patients. The pyramidal tract was visualized in 45, the optic radiation in 22, and the arcuate fasciculus in 13 (two tracts in 9). During the follow-up period of 3 to 72 months (median, 23 months) after the procedure, 1 patient showed permanent worsening of pre-existing dysesthesia, and another patient exhibited mild transient hemiparesis 12 months later but fully recovered after oral administration of corticosteroid agents. Two patients had transient speech disturbance before starting integration of the arcuate fasciculus tractography, but no patient thereafter. Conclusion: Integrating tractography helped prevent morbidity of radiosurgery in patients with brain arteriovenous malformations.

  9. A simulation and training environment for robotic radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Schlaefer, Alexander [University of Luebeck, Institute for Robotics and Cognitive Systems, Luebeck (Germany); Stanford University, Department of Radiation Oncology, Stanford, CA (United States); Gill, Jakub; Schweikard, Achim [University of Luebeck, Institute for Robotics and Cognitive Systems, Luebeck (Germany)

    2008-09-15

    To provide a software environment for simulation of robotic radiosurgery, particularly to study the effective robot workspace with respect to the treatment plan quality, and to illustrate the concepts of robotic radiosurgery. A simulation environment for a robotic radiosurgery system was developed using Java and Java3D. The kinematics and the beam characteristics were modeled and linked to a treatment planning module. Simulations of different robot workspace parameters for two example radiosurgical patient cases were performed using the novel software tool. The first case was an intracranial lesion near the left inner ear, the second case was a spinal lesion. The planning parameters for both cases were visualized with the novel simulation environment. An incremental extension of the robot workspace had limited effect for the intracranial case, where the original workspace already covered the left side of the patient. For the spinal case, a larger workspace resulted in a noticeable improvement in plan quality and a large portion of the beams being delivered from the extended workspace. The new software environment is useful to simulate and analyze parameters and configurations for robotic radiosurgery. An enlarged robot workspace may result in improved plan quality depending on the location of the target region. (orig.)

  10. A simulation and training environment for robotic radiosurgery

    International Nuclear Information System (INIS)

    Schlaefer, Alexander; Gill, Jakub; Schweikard, Achim

    2008-01-01

    To provide a software environment for simulation of robotic radiosurgery, particularly to study the effective robot workspace with respect to the treatment plan quality, and to illustrate the concepts of robotic radiosurgery. A simulation environment for a robotic radiosurgery system was developed using Java and Java3D. The kinematics and the beam characteristics were modeled and linked to a treatment planning module. Simulations of different robot workspace parameters for two example radiosurgical patient cases were performed using the novel software tool. The first case was an intracranial lesion near the left inner ear, the second case was a spinal lesion. The planning parameters for both cases were visualized with the novel simulation environment. An incremental extension of the robot workspace had limited effect for the intracranial case, where the original workspace already covered the left side of the patient. For the spinal case, a larger workspace resulted in a noticeable improvement in plan quality and a large portion of the beams being delivered from the extended workspace. The new software environment is useful to simulate and analyze parameters and configurations for robotic radiosurgery. An enlarged robot workspace may result in improved plan quality depending on the location of the target region. (orig.)

  11. SU-E-T-642: Safety Procedures for Error Elimination in Cyberknife Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT)

    International Nuclear Information System (INIS)

    Hussain, A; Alkafi, A; Al-Najjar, W; Moftah, B

    2014-01-01

    Purpose: Cyberknife system is used for providing stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) hypofractionation scheme. The whole treatment delivery is based on live imaging of the patient. The minor error made at any stage may bring severe radiation injury to the patient or damage to the system itself. Several safety measures were taken to make the system safer. Methods: The radiation treatment provided thru a 6MV linac attached to Kuka robot (Cyberknife G4, Accuray Inc. Sunnyvale, CA, USA). Several possible errors were identified related to patient alignment, treatment planning, dose delivery and physics quality assurance. During dose delivery, manual and visual checks were introduced to confirm pre and intra-treatment imaging to reduce possible errors. One additional step was introduced to confirm that software tracking-tools had worked correctly with highest possible confidence level. Robotic head move in different orientations over and around the patient body, the rigidity of linac-head cover and other accessories was checked periodically. The vender was alerted when a tiny or bigger piece of equipment needed additional interlocked support. Results: As of our experience treating 525 patients on Cyberknife during the last four years, we saw on and off technical issues. During image acquisition, it was made essential to follow the site-specific imaging protocols. Adequate anatomy was contoured to document the respective doses. Followed by auto-segmentation, manual tweaking was performed on every structure. The calculation box was enclosing the whole image during the final calculation. Every plan was evaluated on slice-by slice basis. To review the whole process, a check list was maintained during the physics 2nd-check. Conclusion: The implementation of manual and visual additional checks introduced along with automated checks for confirmation was found promising in terms of reduction in systematic errors and making the system

  12. X-ray stereotactic radiosurgery for cerebral arteriovenous malformation in the teenagers

    International Nuclear Information System (INIS)

    Wang Qing; Huang Minggang; Hou Xiaoling

    2002-01-01

    Objective: To analyze the long-term results of cerebral arteriovenous malformation (AVM) in the teenagers treated by X-ray stereotactic radiosurgery (SRS). Methods: From May 1996 to May 1998, 66 patients with AVM were treated by X-ray SRS with 65 patients followed up for 3-5 years. There were 42 men and 24 women who ranged in age from 8 to 39 years. The AVM volume ranged from 0.32 cm 3 to 42.88 cm 3 . The peripheral dose was prescribed to the 80% isodose line, which ranged from 18 Gy to 23 Gy, with a median of 19.3 Gy. Results: The complete obliteration rate was 65.2%, with 30.3% at 1 year and 62.1% at 2 years. Logistic regression analysis showed that the lesion volume was the only factor for obliteration, the complete obliteration rates were 87.1% and 45.7% for 3 and >10 cm 3 (x 2 = 10.644, P 3 and > 10 cm 3 (t = 2.066, P 20 Gy and 2 = 0.003, P > 0.05) and 1.474 years, 1.667 years (t = 1.073, P > 0.05) for children and young people, showing irrelevancy to age. Conclusions: The X-ray SRS is effective and safe for cerebral AVM, it gives high obliteration rate for AVM of volume 3 and serves as an auxiliary to surgery and endovascular embolization

  13. Proton Stereotactic Radiosurgery for the Treatment of Benign Meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Halasz, Lia M., E-mail: lhalasz@partners.org [Harvard Radiation Oncology Program, Boston, Massachusetts (United States); Harvard Medical School, Boston, Massachusetts (United States); Bussiere, Marc R.; Dennis, Elizabeth R.; Niemierko, Andrzej [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Chapman, Paul H. [Department of Neurosurgery, Massachusetts General Hospital, Boston, Massachusetts (United States); Harvard Medical School, Boston, Massachusetts (United States); Loeffler, Jay S.; Shih, Helen A. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Harvard Medical School, Boston, Massachusetts (United States)

    2011-12-01

    Purpose: Given the excellent prognosis for patients with benign meningiomas, treatment strategies to minimize late effects are important. One strategy is proton radiation therapy (RT), which allows less integral dose to normal tissue and greater homogeneity than photon RT. Here, we report the first series of proton stereotactic radiosurgery (SRS) used for the treatment of meningiomas. Methods and Materials: We identified 50 patients with 51 histologically proven or image- defined, presumed-benign meningiomas treated at our institution between 1996 and 2007. Tumors of <4 cm in diameter and located {>=}2 mm from the optic apparatus were eligible for treatment. Indications included primary treatment (n = 32), residual tumor following surgery (n = 8), and recurrent tumor following surgery (n = 10). The median dose delivered was 13 Gray radiobiologic equivalent (Gy[RBE]) (range, 10.0-15.5 Gy[RBE]) prescribed to the 90% isodose line. Results: Median follow-up was 32 months (range, 6-133 months). Magnetic resonance imaging at the most recent follow-up or time of progression revealed 33 meningiomas with stable sizes, 13 meningiomas with decreased size, and 5 meningiomas with increased size. The 3-year actuarial tumor control rate was 94% (95% confidence interval, 77%-98%). Symptoms were improved in 47% (16/ 34) of patients, unchanged in 44% (15/34) of patients, and worse in 9% (3/34) of patients. The rate of potential permanent adverse effects after SRS was 5.9% (3/51 patients). Conclusions: Proton SRS is an effective therapy for small benign meningiomas, with a potentially lower rate of long-term treatment-related morbidity. Longer follow-up is needed to assess durability of tumor control and late effects.

  14. Stereotactic Radiosurgery with Neoadjuvant Embolization of Larger Arteriovenous Malformations: An Institutional Experience

    Directory of Open Access Journals (Sweden)

    Richard Dalyai

    2014-01-01

    Full Text Available Objective. This study investigates the safety and efficacy of a multimodality approach combining staged endovascular embolizations with subsequent SRS for the management of larger AVMs. Methods. Ninety-five patients with larger AVMs were treated with staged endovascular embolization followed by SRS between 1996 and 2011. Results. The median volume of AVM in this series was 28 cm3 and 47 patients (48% were Spetzler-Martin grade IV or V. Twenty-seven patients initially presented with hemorrhage. Sixty-one patients underwent multiple embolizations while a single SRS session was performed in 64 patients. The median follow-up after SRS session was 32 months (range 9–136 months. Overall procedural complications occurred in 14 patients. There were 13 minor neurologic complications and 1 major complication (due to embolization while four patients had posttreatment hemorrhage. Thirty-eight patients (40% were cured radiographically. The postradiosurgery actuarial rate of obliteration was 45% at 5 years, 56% at 7 years, and 63% at 10 years. In multivariate analysis, larger AVM size, deep venous drainage, and the increasing number of embolization/SRS sessions were negative predictors of obliteration. The number of embolizations correlated positively with the number of stereotactic radiosurgeries (P<0.005. Conclusions. Multimodality endovascular and radiosurgical approach is an efficacious treatment strategy for large AVM.

  15. Stereotactic radiosurgery for the treatment of arteriovenous malformations - preliminary results; Radiocirurgia estereotaxica no tratamento das malformacoes arteriovenosas - resultados preliminares

    Energy Technology Data Exchange (ETDEWEB)

    Penna, Antonio Belmiro Rodrigues Campbell [Hospital dos Servidores do Estado (HSE), Rio de Janeiro, RJ (Brazil). Servico de Radioterapia; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Vieira, Sergio Lannes [Hospital Sao Vicente de Paulo, Rio de Janeiro, RJ (Brazil). Servico de Radioterapia; Rossini Junior, Olamir [Clinica Radioterapia Botafogo Ltda., Rio de Janeiro, RJ (Brazil)

    2000-08-01

    This paper presents the clinical and radiological results of six patients treated with stereotactic radiosurgery with a 6 MeV linear accelerator for arteriovenous malformations. All patients had been previously examined by neurosurgeons and neuroradiologists who contraindicated surgery or embolization due to the size and location of the nidus. Radiological investigations performed 12 to 36 months after the treatments showed complete response in five patients and partial response in one patient, adding up to a total response rate of 100%. No signs or symptoms of permanent injury to the cranial nerves or cerebral parenchyma were detected up to the last follow-up visit. No episodes of cerebral hemorrhage were diagnosed and no deaths related to the radiosurgical treatment were reported during the follow-up period. (author)

  16. Efficient and accurate stereotactic radiotherapy using flattening filter free beams and HexaPOD robotic tables

    DEFF Research Database (Denmark)

    Nielsen, Morten; Hansen, C. R.; Brink, C.

    2016-01-01

    Flattening filter free (FFF) high dose rate beam technique was introduced for brain stereotactic radiosurgery (SRS) and lung Stereotactic Body Radiotherapy (SBRT). Furthermore, a HexaPOD treatment table was introduced for the brain SRS to enable correction of rotational setup errors. 19 filter fl...

  17. SU-E-J-123: Targeting Accuracy of Image-Guided Radiosurgery for Intracranial Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Y; Wen, N; Zhao, B; Kim, J; Gordon, J; Chetty, I [Henry Ford Health System, Detroit, MI (United States)

    2014-06-01

    Purpose: To evaluate the setup accuracies of image-guided intracranial radiosurgery across several different linear accelerator platforms. Methods: A CT scan with a slice thickness of 1.0 mm was acquired of a Rando head phantom (The Phantom Laboratory) in a U-frame mask (BrainLAB AG). The phantom had three embedded BBs, simulating a central, left, and anterior lesion. The phantom was setup with each BB placed at the radiation isocenter under image guidance. Four different setup procedures were investigated: (1) NTX-ExacTrac: 6 degree-of-freedom (6D) correction on a Novalis Tx (BrainLAB AG) with ExacTrac localization (BrainLAB AG); (2) NTX-CBCT: 4D correction on the Novalis Tx with cone-beam computed tomography (CBCT); (3) TrueBeam-CBCT: 4D correction on a TrueBeam (Varian) with CBCT; (4) Edge-CBCT: 6D correction on an Edge (Varian) with CBCT. The experiment was repeated 5 times with different initial setup error at each BB location on each platform, and the mean (μ) and one standard deviation (σ) of the residual error was compared.The congruence between radiation and imaging isocenters on each platform was evaluated by acquiring Winston Lutz (WL) images of a WL jig followed by imaging using ExacTrac or CBCT. The difference in coordinates of the jig relative to radiation and imaging isocenters was then recorded. Results: Averaged over all three BB locations, the residual vector setup errors (μ±σ) of the phantom in mm were 0.6±0.2, 1.0±0.5, 0.2±0.1, and 0.3±0.1 on NTX-ExacTrac, NTX-CBCT, TrueBeam-CBCT, and Edge-CBCT, with their ranges in mm being 0.4∼1.1, 0.4∼1.9, 0.1∼0.5, and 0.2∼0.6, respectively. And imaging isocenter was found stable relative to radiation isocenter, with the congruence to radiation isocenter in mm being 0.6±0.1, 0.7±0.1, 0.3±0.1, 0.2±0.1, respectively, on the four systems in the same order. Conclusion: Millimeter accuracy can be achieved with image-guided radiosurgery for intracranial lesions based on this set of experiments.

  18. Fractionated radiosurgery for 9L gliosarcoma in the rat brain

    International Nuclear Information System (INIS)

    Kim, Jae Ho; Khil, Mark S.; Kolozsvary, Andrew; Gutierrez, Jorge A.; Brown, Stephen L.

    1999-01-01

    Purpose: Fractionated radiosurgery is being carried out in the clinic to improve the therapeutic ratio of single-dose radiosurgery using various fractionation schemes. Because there is a paucity of experimental radiobiological data in the literature on the tumor response and late-responding normal tissue of critical intracranial structures to radiosurgery, the present animal study was designed to compare the response following a single high dose of radiation with that obtained from calculated fractionated doses of radiosurgery. Methods and Materials: Male Fischer rats with 9L gliosarcoma growing in their brains were stereotactically irradiated and assayed for the tumor control rate and brain tissue damage. The radiation dose needed for 50% tumor control (TCD 50 ) was used as the endpoint of the efficacy of radiosurgery. Normal brain damage was measured histologically following a period of time over 270 days. Histological evaluation included hematoxylin-eosin (H and E), Luxol fast blue and periodic acid Schiff (LFB/PAS) for the presence of myelin and glial fibrillary acidic protein (GFAP) for the assessment of astrocytic re-activity. The optical density of optic nerves and chiasms staining with LFB/PAS was quantitatively measured using a computer image analysis to assess the magnitude of demyelination. Results: Radiosurgery (RS) was found to be more effective in curing small tumors than large tumors. The dose required to control 50% of the tumored animals for 120 days was 24, 31, and 40 Gy for 2-, 6-, and 12-day-old tumors, respectively. Using 12-day-old brain tumors, two fractions of 23.5 Gy and three fractions of 18.5 Gy were found to be equivalent to the single dose of 35 Gy for tumor control. For normal brain damages, the visual pathways including optic nerves and chiasm were found to be highly radiosensitive structures. A single dose of 35 Gy produced 100% severe optic neuropathy. The fractionated RS regimens spared substantial optic nerve damage. Conclusion

  19. Completion of Gamma Knife radiosurgery for AVM treatment after unplanned interruption-technical note.

    Science.gov (United States)

    Raman, Hari S; Santanam, Lakshmi; Vellimana, Ananth K; Drzymala, Robert E; Tsien, Christina I; Zipfel, Gregory J

    2018-02-17

    Gamma Knife radiosurgery is an established technique for non-urgent treatment of various intracranial pathologies. Intra-procedural dislodgement of the stereotactic frame is an uncommon occurrence that could lead to abortion of ongoing treatment and necessitate more invasive treatment strategies. In this case report, we describe a novel method for resumption of Gamma Knife treatment after an unplanned intra-procedural interruption. The case example involves a radiosurgical treatment of a Spetzler-Martin grade I arteriovenous malformation. Our technique involves integration of scans and coordinate systems from two imaging sessions using the composite isodose line to resolve translational differences, thereby limiting delivery of remaining shots to the untreated region of the lesion. MRI follow-up at 13 months showed a reduction in the nidus size with no evidence of any radiation injury to the surrounding brain parenchyma. We believe this technique will allow care teams to effectively salvage interrupted Gamma Knife procedures and reduce progression to more invasive treatment options.

  20. Quality assurance system to correct for errors arising from couch rotation in linac-based stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Brezovich, Ivan A.; Pareek, Prem N.; Plott, W. Eugene; Jennelle, Richard L. S.

    1997-01-01

    Purpose: The purpose of this project was the development of a quality assurance (QA) system that would provide geographically accurate targeting for linac-based stereotactic radiosurgery (LBSR). Methods and Materials: The key component of our QA system is a novel device (Alignment Tool) for expedient measurement of gantry and treatment table excursions (wobble) during rotation. The Alignment Tool replaces the familiar pencil-shaped pointers with a ball pointer that is used with the field light of the accelerator to indicate alignment of beam and target. Wobble is measured prior to each patient treatment and analyzed together with the BRW coordinates of the target by a spreadsheet. The corrections required to compensate for any imprecision are identified, and a printout generated indicating the floor stand coordinates for each couch angle used to place the target at isocenter. Results: The Alignment Tool has an inherent accuracy of measurement better than 0.1 mm. The overall targeting error of our QA method, found by evaluating 177 target simulator films of 55 foci in 40 randomly selected patients, was 0.47 ± 0.23 mm. The Alignment Tool was also valuable during installation of the floor stand and a supplemental collimator for the accelerator. Conclusions: The QA procedure described allows accurate targeting in LBSR, even when couch rotation is imprecise. The Alignment Tool can facilitate the installation of any stereotactic irradiation system, and can be useful for annual QA checks as well as in the installation and commissioning of new accelerators

  1. Cognitive function in patients with cerebral arteriovenous malformations after radiosurgery: prospective long-term follow-up

    International Nuclear Information System (INIS)

    Steinvorth, Sarah; Wenz, Frederik; Wildermuth, Susanne; Essig, Marco; Fuss, Martin; Lohr, Frank; Debus, Juergen; Wannenmacher, Michael; Hacke, Werner

    2002-01-01

    Purpose: To evaluate the long-term cognitive function of patients with cerebral arteriovenous malformations (AVMs) after radiosurgery. Methods and Materials: The data of 95 AVM patients were prospectively assessed up to 3 years after radiosurgery. Of these patients, 39 had a follow-up of at least 2 years. Radiosurgery was performed using a modified linear accelerator (minimal doses to the target volume 15-22 Gy, median dose 20). The neuropsychological evaluation included testing of intelligence, attention, and memory. The effect of a preexisting intracranial hemorrhage, as well as AVM occlusion, on cognitive functions was analyzed after 1 and 2 years. Results: No cognitive declines were observed during follow-up. Instead significant improvements occurred in intelligence (1 year, +6.1 IQ points; 2 years, +5.1 IQ points), memory (1 year, +18.3 percentile score; 2 years, +12.2 percentile score), and attention (1 year, +19 percentile score; 2 years, +18 percentile score). Patients without previous intracranial hemorrhage improved more than patients with intracranial hemorrhage, although this difference was not statistically significant. The role of AVM occlusion on cognitive function is not clear at present. Conclusion: Radiosurgery does not induce measurable deterioration of cognitive function in patients with cerebral AVMs

  2. Reirradiation of brain and skull base tumors with fractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Tokuuye, Koichi; Akine, Yasuyuki; Sumi, Minako; Kagami, Yoshikazu; Ikeda, Hiroshi; Oyama, Hiroshi; Inou, Yasushi; Shibui, Soichiro; Nomura, Kazuhiro

    1998-01-01

    Purpose: We evaluated the feasibility of fractionated stereotactic radiotherapy for small intracranial recurrences after conventional radiotherapy. Methods and Materials: Nineteen patients who had initially undergone conventional radiotherapy to intracranial lesions, receiving a median total dose of 50 Gy in 5 weeks, were retreated with stereotactic radiotherapy for their recurrences and received a median total dose of 42 Gy in seven fractions over 2.3 weeks. Results: Of the 19 patients, 15 achieved local control 3-51 months after reirradiation. No patient suffered from acute reaction, but one patient with a history of extensive radiotherapy developed progressive radionecrosis 9 months after reirradiation. Conclusions: Fractionated stereotactic radiotherapy of intracranial recurrences appears to be effective in achieving in local control with negligible morbidity. We believe it merits further investigation in a prospective study

  3. Radiosurgery for arteriovenous malformations based on magnetic resonance angiography

    International Nuclear Information System (INIS)

    Mehta, Minesh; Kubsad, Shrikant; Petereit, Daniel; Turski, Patrick; Levin, Allan; Kinsella, Timothy

    1993-01-01

    Magnetic Resonance Angiography (MRA) was performed to establish its feasibility, compare it with standard angiography (SA), employ MRA in follow-up and semiquantify AVM flow velocity (FV). A correlative evaluation between flow velocity and response to stereotactic radiosurgery was also attempted. (author). 8 refs., 1 tab

  4. WE-A-304-02: Strategies and Technologies for Cranial Radiosurgery Planning: Gamma Knife

    International Nuclear Information System (INIS)

    Schlesinger, D.

    2015-01-01

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB

  5. WE-A-304-02: Strategies and Technologies for Cranial Radiosurgery Planning: Gamma Knife

    Energy Technology Data Exchange (ETDEWEB)

    Schlesinger, D. [University of Virginia Health Systems (United States)

    2015-06-15

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB.

  6. Stereotactic radiosurgery and fractionated stereotactic radiotherapy for the treatment of acoustic schwannomas: comparative observations of 125 patients treated at one institution

    International Nuclear Information System (INIS)

    Andrews, David W.; Suarez, Oscar; Goldman, H. Warren; Downes, M. Beverly; Bednarz, Greg; Corn, Benjamin W.; Werner-Wasik, Maria; Rosenstock, Jeffrey; Curran, Walter J.

    2001-01-01

    Background: Stereotactic radiosurgery (SRS) and, more recently, fractionated stereotactic radiotherapy (SRT) have been recognized as noninvasive alternatives to surgery for the treatment of acoustic schwannomas. We review our experience of acoustic tumor treatments at one institution using a gamma knife for SRS and the first commercial world installation of a dedicated linac for SRT. Methods: Patients were treated with SRS on the gamma knife or SRT on the linac from October 1994 through August 2000. Gamma knife technique involved a fixed-frame multiple shot/high conformality single treatment, whereas linac technique involved daily conventional fraction treatments involving a relocatable frame, fewer isocenters, and high conformality established by noncoplanar arc beam shaping and differential beam weighting. Results: Sixty-nine patients were treated on the gamma knife, and 56 patients were treated on the linac, with 1 NF-2 patient common to both units. Three patients were lost to follow-up, and in the remaining 122 patients, mean follow-up was 119±67 weeks for SRS patients and 115±96 weeks for SRT patients. Tumor control rates were high (≥97%) for sporadic tumors in both groups but lower for NF-2 tumors in the SRT group. Cranial nerve morbidities were comparably low in both groups, with the exception of functional hearing preservation, which was 2.5-fold higher in patients who received conventional fraction SRT. Conclusion: SRS and SRT represent comparable noninvasive treatments for acoustic schwannomas in both sporadic and NF-2 patient groups. At 1-year follow-up, a significantly higher rate of serviceable hearing preservation was achieved in SRT sporadic tumor patients and may therefore be preferable to alternatives including surgery, SRS, or possibly observation in patients with serviceable hearing

  7. Rare case of malignant craniopharyngioma reactive to adjunctive stereotactic radiotherapy and chemotherapy; Case report and review.

    Science.gov (United States)

    Nomura, Shunsunke; Aihara, Yasuo; Amano, Kosaku; Eguchi, Seiichiro; Chiba, Kentaro; Komori, Takashi; Kawamata, Takakazu

    2018-06-19

    Malignant craniopharyngioma or anaplastic craniopharyngioma was first reported in 1987 by Akachi. It has a malignant clinical and histological feature; remarkably rapid progression, atypical pathology like squamous cell carcinoma and poor prognosis. To date seventeen cases of malignant craniopharyngioma have been reported and of these cases, most were of secondary malignant tumor in nature. With respect to traditional benign craniopharyngioma, adjunctive treatment after gross total removal is not necessary, but in the case of malignant types of the tumor, adjunctive treatment is important. This paper presents the first case of malignant craniopharyngioma reactive to adjunctive Gamma knife stereotactic radiosurgery and chemotherapy. Malignant craniopharyngioma is very rare, and we report Gamma knife stereotactic radiosurgery and chemotherapy (Carboplatine and etoposide chemotherapy), as well as Temozolomide chemotherapy were effective and could control progression of the tumor temporarily. Since adjunctive Gamma knife stereotactic radiosurgery and chemotherapy of malignant craniopharyngioma cases affects follow-up strategies, we propose supporting the need to a revision to the WHO classification regarding malignancy evaluation of craniopharyngioma. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Gamma knife radiosurgery under general anesthesia in childhood

    International Nuclear Information System (INIS)

    Higuchi, Yoshinori; Serizawa, Toru; Nagano, Osamu

    2008-01-01

    Gamma knife radiosurgery (GKS) is an important treatment option for pediatric intracranial diseases, such as arteriovenous malformations and brain tumors. To perform GKS in children, general anesthesia is required for placing a stereotactic frame around the head of the patient, who must remain supine for the entire procedure. This report describes the anesthetic management of children who have undergone GKS at our institution. Fifty-one GKS procedures were performed in 43 patients (age range, 2-15 years). Twenty-one patients had arteriovenous malformations, and 14 patients had brain tumors. Twenty-nine patients (67.4%) received general anesthesia. All children 10 years or younger were treated under general anesthesia. General anesthesia for GKS is performed outside of the operating room and involves unique conditions. First, the patients must be transported to multiple sites in the hospital (the neuroangiography suite, the department of radiology for magnetic resonance imaging and computed tomography, and the gamma knife unit). Second, general anesthesia must be maintained in a high magnetic field. Third, medical staff, including anesthesiologists, must remain outside the room during irradiation. Safe and efficient general anesthesia is essential for performing GKS in children. (author)

  9. Biophysical characterization of a relativistic proton beam for image-guided radiosurgery.

    Science.gov (United States)

    Yu, Zhan; Vanstalle, Marie; La Tessa, Chiara; Jiang, Guo-Liang; Durante, Marco

    2012-07-01

    We measured the physical and radiobiological characteristics of 1 GeV protons for possible applications in stereotactic radiosurgery (image-guided plateau-proton radiosurgery). A proton beam was accelerated at 1 GeV at the Brookhaven National Laboratory (Upton, NY) and a target in polymethyl methacrylate (PMMA) was used. Clonogenic survival was measured after exposures to 1-10 Gy in three mammalian cell lines. Measurements and simulations demonstrate that the lateral scattering of the beam is very small. The lateral dose profile was measured with or without the 20-cm plastic target, showing no significant differences up to 2 cm from the axis A large number of secondary swift protons are produced in the target and this leads to an increase of approximately 40% in the measured dose on the beam axis at 20 cm depth. The relative biological effectiveness at 10% survival level ranged between 1.0 and 1.2 on the beam axis, and was slightly higher off-axis. The very low lateral scattering of relativistic protons and the possibility of using online proton radiography during the treatment make them attractive for image-guided plateau (non-Bragg peak) stereotactic radiosurgery.

  10. Biophysical characterization of a relativistic proton beam for image-guided radiosurgery

    International Nuclear Information System (INIS)

    Yu, Z.; Vanstalle, M.; La Tessa, C.; Durante, M.; Jiang Guoliang

    2012-01-01

    We measured the physical and radiobiological characteristics of 1 GeV protons for possible applications in stereotactic radiosurgery (image-guided plateau-proton radiosurgery). A proton beam was accelerated at 1 GeV at the Brookhaven National Laboratory (Upton, NY) and a target in polymethyl methacrylate (PMMA) was used. Clonogenic survival was measured after exposures to 1-10 Gy in three mammalian cell lines. Measurements and simulations demonstrate that the lateral scattering of the beam is very small. The lateral dose profile was measured with or without the 20-cm plastic target, showing no significant differences up to 2 cm from the axis A large number of secondary swift protons are produced in the target and this leads to an increase of approximately 40% in the measured dose on the beam axis at 20 cm depth. The relative biological effectiveness at 10% survival level ranged between 1.0 and 1.2 on the beam axis, and was slightly higher off-axis. The very low lateral scattering of relativistic protons and the possibility of using online proton radiography during the treatment make them attractive for image-guided plateau (non-Bragg peak) stereotactic radiosurgery. (author)

  11. Parametric curve evaluation of a phototransistor used as detector in stereotactic radiosurgery X-ray beam

    International Nuclear Information System (INIS)

    Lima, Daniela Pontes A.; Santos, Luiz Antonio P.; Santos, Walter M.; Silva Junior, Eronides F. da

    2005-01-01

    Phototransistors have been widely used as detectors for low energy X-rays. However, when they are used in high energy X-rays fields like those generated from linear accelerators (linac), there is a certain loss of sensibility to the ionizing radiation. This damage is cumulative and irreversible. Thus, a correction factor must be applied to its response, which is proportional to the integrated dose. However, it is possible to estimate the correction factor by using the V x I parametric curve of the device. The aim of this work was to develop studies to evaluate and correlate the parametric response curve of a phototransistor with its loss of sensibility after irradiation. An Agilent 4155C semiconductor parameter analyzer was used to trace the parametric curve. X-rays were generated by a 14 MV Primus-Siemens linear accelerator. The results demonstrated that there is a correlation between the integrated dose applied to the phototransistor and the parametric response of the device. Studies are under way to determine how such behavior can provide information for the dosimetric planning in stereotactic radiosurgery. (author)

  12. A deep convolutional neural network-based automatic delineation strategy for multiple brain metastases stereotactic radiosurgery.

    Directory of Open Access Journals (Sweden)

    Yan Liu

    Full Text Available Accurate and automatic brain metastases target delineation is a key step for efficient and effective stereotactic radiosurgery (SRS treatment planning. In this work, we developed a deep learning convolutional neural network (CNN algorithm for segmenting brain metastases on contrast-enhanced T1-weighted magnetic resonance imaging (MRI datasets. We integrated the CNN-based algorithm into an automatic brain metastases segmentation workflow and validated on both Multimodal Brain Tumor Image Segmentation challenge (BRATS data and clinical patients' data. Validation on BRATS data yielded average DICE coefficients (DCs of 0.75±0.07 in the tumor core and 0.81±0.04 in the enhancing tumor, which outperformed most techniques in the 2015 BRATS challenge. Segmentation results of patient cases showed an average of DCs 0.67±0.03 and achieved an area under the receiver operating characteristic curve of 0.98±0.01. The developed automatic segmentation strategy surpasses current benchmark levels and offers a promising tool for SRS treatment planning for multiple brain metastases.

  13. Measurement of dosimetric parameters and dose verification in stereotactic radiosurgery (SRS)

    International Nuclear Information System (INIS)

    Reduan Abdullah; Nik Ruzman Nik Idris; Ahmad Lutfi Yusof; Mazurawati Mohamed

    2013-01-01

    Full-text: The purpose of this study was to measure the dosimetric parameters for small photon beams to be used as input data treatment planning computer system (TPS) and to verify dose calculated by TPS in Stereotactic Radiosurgery (SRS) procedure. The beam data required were Percentage Depth Dose (PDD), Off-axis Ratio (OAR), and Scatter Factor of Relative Output Factor. Small beams of 5 mm to 45 mm diameter circular cone collimators used in SRS were utilized for beam data measurements measured using pinpoint 3D ionization chamber (0.016 cc). For second part of this study, we reported the important quality assurance (QA) procedures before SRS treatment that influenced the dose delivery. These QA procedures consist of measurements on the accuracy in target localization and room laser alignment. The dose calculated to be delivered for treatment was verified using pinpoint 3D ionization chamber and TLD 100H. The mean deviation of measured dose using TLD 100H compared to calculated dose was 3.37 %. Beside that, pinpoint ionization 3D chamber give more accurate results of dose compared to TLD 100H. The measured dose using pinpoint 3D ionization chamber are good agreement with calculated dose by TPS with deviation of 2.17 %. The results are acceptable such as recommended by International Commission on Radiation Units and Measurements (ICRU) Report No. 50 (1993) that dose delivered to the target volume must be within ±5 % error. (author)

  14. Frame-less and mask-less cranial stereotactic radiosurgery: a feasibility study

    International Nuclear Information System (INIS)

    Cervino, Laura I; Pawlicki, Todd; Lawson, Joshua D; Jiang, Steve B

    2010-01-01

    Currently, high-precision delivery in stereotactic radiosurgery (SRS) is achieved via high-precision target localization and rigid patient immobilization. Rigid patient immobilization can result in, however, patient discomfort, which is exacerbated by the long duration of SRS treatments and may induce patient movement. To address this issue, we developed a new SRS technique that is aimed to minimize patient discomfort while maintaining high-precision treatment, based on a less-rigid patient immobilization combined with continuous patient motion monitoring. In this paper, we examine the feasibility of this new technique. An anthropomorphic head phantom is used to check the accuracy of a 3D surface imaging system that provides the monitoring. Volunteers are used to study patient motion inside a new type of head mold that is used for minimal immobilization. Results show that for different couch angles, the difference between the phantom positions recorded by the surface imaging system and by an infrared optical tracking system was within 1 mm in displacements and 1 deg. in rotation. The motion detected by both systems during couch shifts is within 1 mm agreement. The average maximum volunteer head motion in the head mold during the 20 min interval in any direction was 0.7 mm (range: 0.4-1.1 mm). Patient motion due to couch motion was always less than 0.2 mm. We conclude that motion inside the minimally immobilizing head mold is small and can be accurately detected by real-time surface imaging.

  15. Frame-less and mask-less cranial stereotactic radiosurgery: a feasibility study

    Science.gov (United States)

    Cerviño, Laura I.; Pawlicki, Todd; Lawson, Joshua D.; Jiang, Steve B.

    2010-04-01

    Currently, high-precision delivery in stereotactic radiosurgery (SRS) is achieved via high-precision target localization and rigid patient immobilization. Rigid patient immobilization can result in, however, patient discomfort, which is exacerbated by the long duration of SRS treatments and may induce patient movement. To address this issue, we developed a new SRS technique that is aimed to minimize patient discomfort while maintaining high-precision treatment, based on a less-rigid patient immobilization combined with continuous patient motion monitoring. In this paper, we examine the feasibility of this new technique. An anthropomorphic head phantom is used to check the accuracy of a 3D surface imaging system that provides the monitoring. Volunteers are used to study patient motion inside a new type of head mold that is used for minimal immobilization. Results show that for different couch angles, the difference between the phantom positions recorded by the surface imaging system and by an infrared optical tracking system was within 1 mm in displacements and 1° in rotation. The motion detected by both systems during couch shifts is within 1 mm agreement. The average maximum volunteer head motion in the head mold during the 20 min interval in any direction was 0.7 mm (range: 0.4-1.1 mm). Patient motion due to couch motion was always less than 0.2 mm. We conclude that motion inside the minimally immobilizing head mold is small and can be accurately detected by real-time surface imaging.

  16. Long-term Evaluation of Radiation-Induced Optic Neuropathy After Single-Fraction Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Leavitt, Jacqueline A.; Stafford, Scott L.; Link, Michael J.; Pollock, Bruce E.

    2013-01-01

    Purpose: To determine the long-term risk of radiation-induced optic neuropathy (RION) in patients having single-fraction stereotactic radiosurgery (SRS) for benign skull base tumors. Methods and Materials: Retrospective review of 222 patients having Gamma Knife radiosurgery for benign tumors adjacent to the anterior visual pathway (AVP) between 1991 and 1999. Excluded were patients with prior or concurrent external beam radiation therapy or SRS. One hundred twenty-nine patients (58%) had undergone previous surgery. Tumor types included confirmed World Health Organization grade 1 or presumed cavernous sinus meningioma (n=143), pituitary adenoma (n=72), and craniopharyngioma (n=7). The maximum dose to the AVP was ≤8.0 Gy (n=126), 8.1-10.0 Gy (n=39), 10.1-12.0 Gy (n=47), and >12 Gy (n=10). Results: The mean clinical and imaging follow-up periods were 83 and 123 months, respectively. One patient (0.5%) who received a maximum radiation dose of 12.8 Gy to the AVP developed unilateral blindness 18 months after SRS. The chance of RION according to the maximum radiation dose received by the AVP was 0 (95% confidence interval [CI] 0-3.6%), 0 (95% CI 0-10.7%), 0 (95% CI 0-9.0%), and 10% (95% CI 0-43.0%) for patients receiving ≤8 Gy, 8.1-10.0 Gy, 10.1-12.0 Gy, and >12 Gy, respectively. The overall risk of RION in patients receiving >8 Gy to the AVP was 1.0% (95% CI 0-6.2%). Conclusions: The risk of RION after single-fraction SRS in patients with benign skull base tumors who have no prior radiation exposure is very low if the maximum dose to the AVP is ≤12 Gy. Physicians performing single-fraction SRS should remain cautious when treating lesions adjacent to the AVP, especially when the maximum dose exceeds 10 Gy

  17. Long-term Evaluation of Radiation-Induced Optic Neuropathy After Single-Fraction Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Leavitt, Jacqueline A., E-mail: leavitt.jacqueline@mayo.edu [Department of Ophthalmology, Mayo Clinic and Foundation, Rochester, Minnesota (United States); Stafford, Scott L. [Department of Radiation Oncology, Mayo Clinic and Foundation, Rochester, Minnesota (United States); Link, Michael J. [Department of Neurosurgery, Mayo Clinic and Foundation, Rochester, Minnesota (United States); Pollock, Bruce E. [Department of Radiation Oncology, Mayo Clinic and Foundation, Rochester, Minnesota (United States); Department of Neurosurgery, Mayo Clinic and Foundation, Rochester, Minnesota (United States)

    2013-11-01

    Purpose: To determine the long-term risk of radiation-induced optic neuropathy (RION) in patients having single-fraction stereotactic radiosurgery (SRS) for benign skull base tumors. Methods and Materials: Retrospective review of 222 patients having Gamma Knife radiosurgery for benign tumors adjacent to the anterior visual pathway (AVP) between 1991 and 1999. Excluded were patients with prior or concurrent external beam radiation therapy or SRS. One hundred twenty-nine patients (58%) had undergone previous surgery. Tumor types included confirmed World Health Organization grade 1 or presumed cavernous sinus meningioma (n=143), pituitary adenoma (n=72), and craniopharyngioma (n=7). The maximum dose to the AVP was ≤8.0 Gy (n=126), 8.1-10.0 Gy (n=39), 10.1-12.0 Gy (n=47), and >12 Gy (n=10). Results: The mean clinical and imaging follow-up periods were 83 and 123 months, respectively. One patient (0.5%) who received a maximum radiation dose of 12.8 Gy to the AVP developed unilateral blindness 18 months after SRS. The chance of RION according to the maximum radiation dose received by the AVP was 0 (95% confidence interval [CI] 0-3.6%), 0 (95% CI 0-10.7%), 0 (95% CI 0-9.0%), and 10% (95% CI 0-43.0%) for patients receiving ≤8 Gy, 8.1-10.0 Gy, 10.1-12.0 Gy, and >12 Gy, respectively. The overall risk of RION in patients receiving >8 Gy to the AVP was 1.0% (95% CI 0-6.2%). Conclusions: The risk of RION after single-fraction SRS in patients with benign skull base tumors who have no prior radiation exposure is very low if the maximum dose to the AVP is ≤12 Gy. Physicians performing single-fraction SRS should remain cautious when treating lesions adjacent to the AVP, especially when the maximum dose exceeds 10 Gy.

  18. A stereotactic adapter compatible with computed tomography

    International Nuclear Information System (INIS)

    Cacak, R.K.; Law, J.D.

    1982-01-01

    One application of computed-tomographic (CT) scanners is the localization of intracranial targets for stereotactic surgery. Unfortunately, conventional stereotactic devices affixed to the patient cause artifacts which obscure anatomic features in CT images. The authors describe the initial phase of a project to eliminate this problem by using an adapter that is free of metallic objects. Localization of the target point relative to the coordinate system of a Leksell stereotactic frame is achieved from CT image measurements

  19. WE-A-304-01: Strategies and Technologies for Cranial Radiosurgery Planning: MLC-Based Linac

    Energy Technology Data Exchange (ETDEWEB)

    Kim, G. [University of California, San Diego (United States)

    2015-06-15

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB.

  20. WE-A-304-01: Strategies and Technologies for Cranial Radiosurgery Planning: MLC-Based Linac

    International Nuclear Information System (INIS)

    Kim, G.

    2015-01-01

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB

  1. Stereotactic radiosurgery improves the survival in patients with solitary brain metastasis: a reasonable alternative to surgery

    International Nuclear Information System (INIS)

    Kwan, H. Cho; Hall, Walter A.; Lee, Andrew K.; Gerbi, Bruce J.; Higgins, Patrick D.; Nussbaum, Eric S.; Chung, K.K. Lee; Bohen, Marva; Clark, H. Brent

    1996-01-01

    Purpose: To evaluate the efficacy of stereotactic radiosurgery (SRS) in patients with solitary brain metastasis from extracranial primary cancer and to compare the outcome with that of external whole brain irradiation with or without surgical resection. Materials and Methods: Between September 1970 and November, 1995, 231 patients with solitary brain metastasis were treated at the Department of Radiation Oncology, University of Minnesota Hospital. One hundred twenty six patients (56%) were treated with external whole brain irradiation (WBI) only (Group 1), seventy three (32%) underwent surgical resection prior to WBI (Group 2) and thirty two (14%) underwent stereotactic radiosurgery (SRS) with WBI (Group 3). Lung (38%) was the most common site of primary cancer, followed by breast (15%), unknown primary (12%), gastro-intestinal tract (10%), skin (malignant melanoma: 9%), kidney (renal cell carcinoma: 8%) and others (9%). The median dose to the whole brain was 3750 cGy in 15 fractions (ranges from 2000 cGy to 5000 cGy). The median radiosurgical dose of 17.5 Gy (range, 12-40 Gy) was delivered to the 40%-90% isodose line encompassing the target. Eighteen patients were treated with SRS for recurrent or persistent disease following WBI and 14 patients received SRS as a boost in conjunction with WBI. Actuarial survival was calculated from the date of treatment according to the Kaplan-Meier method and statistical significance was assessed with the log-rank test. Results: The actuarial median survivals were 3.8 months for Group 1 (ranges from 1 to 84 months), 10.5 months for Group 2 (ranges from 1 to 125 months) and 9.8 months for Group 3 (ranges from 1 to 36 months). The survivals at one and two years were 19% and 6% for Group 1, 47% and 19% for Group 2, and 44% and 21% for Group 3, respectively. The survival advantage of Groups 2 or 3 over Group 1 was statistically significant (p < 0.0001 by log-rank test). There was no survival advantage of surgery (Group 2) over SRS

  2. Stereotactic Radiosurgery for Brainstem Metastases: An International Cooperative Study to Define Response and Toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Trifiletti, Daniel M., E-mail: daniel.trifiletti@gmail.com [Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia (United States); Lee, Cheng-Chia [Department of Neurosurgery, Neurological Institute, Taipei Veteran General Hospital, Taipei, Taiwan (China); Kano, Hideyuki; Cohen, Jonathan [Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania (United States); Janopaul-Naylor, James; Alonso-Basanta, Michelle; Lee, John Y.K. [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Simonova, Gabriela; Liscak, Roman [Department of Radiation and Stereotactic Neurosurgery, Na Homolce Hospital, Prague (Czech Republic); Wolf, Amparo; Kvint, Svetlana [Department of Neurosurgery, New York University Lagone Medical Center, New York, New York (United States); Grills, Inga S.; Johnson, Matthew [Department of Radiation Oncology, Beaumont Health System, Royal Oak, Michigan (United States); Liu, Kang-Du; Lin, Chung-Jung [Department of Neurosurgery, Neurological Institute, Taipei Veteran General Hospital, Taipei, Taiwan (China); Mathieu, David; Héroux, France [Division of Neurosurgery, Université de Sherbrooke, Centre de recherche du CHUS, Sherbrooke, Québec (Canada); Silva, Danilo; Sharma, Mayur [Department of Neurosurgery, Cleveland Clinic, Cleveland, Ohio (United States); Cifarelli, Christopher P. [Departments of Neurosurgery and Radiation Oncology, West Virginia University, Morgantown, West Virginia (United States); and others

    2016-10-01

    Purpose: To pool data across multiple institutions internationally and report on the cumulative experience of brainstem stereotactic radiosurgery (SRS). Methods and Materials: Data on patients with brainstem metastases treated with SRS were collected through the International Gamma Knife Research Foundation. Clinical, radiographic, and dosimetric characteristics were compared for factors prognostic for local control (LC) and overall survival (OS) using univariate and multivariate analyses. Results: Of 547 patients with 596 brainstem metastases treated with SRS, treatment of 7.4% of tumors resulted in severe SRS-induced toxicity (grade ≥3, increased odds with increasing tumor volume, margin dose, and whole-brain irradiation). Local control at 12 months after SRS was 81.8% and was improved with increasing margin dose and maximum dose. Overall survival at 12 months after SRS was 32.7% and impacted by age, gender, number of metastases, tumor histology, and performance score. Conclusions: Our study provides additional evidence that SRS has become an option for patients with brainstem metastases, with an excellent benefit-to-risk ratio in the hands of experienced clinicians. Prior whole-brain irradiation increases the risk of severe toxicity in brainstem metastasis patients undergoing SRS.

  3. Potential clinical efficacy of intensity-modulated conformal therapy

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Buatti, John M.; Bova, Francis J.; Friedman, William A.; Mendenhall, William M.; Zlotecki, Robert A.

    1998-01-01

    Purpose: The purpose of this study was to examine the potential benefit of using intensity-modulated conformal therapy for a variety of lesions currently treated with stereotactic radiosurgery or conventional radiotherapy. Methods and Materials: Intensity-modulated conformal treatment plans were generated for small intracranial lesions, as well as head and neck, lung, breast, and prostate cases, using the Peacock Plan[reg] treatment-planning system (Nomos Corporation). For small intracranial lesions, intensity-modulated conformal treatment plans were compared with stereotactic radiosurgery treatment plans generated for patient treatment at the University of Florida Shands Cancer Center. For other sites (head and neck, lung, breast, and prostate), plans generated using the Peacock Plan[reg] were compared with conventional treatment plans, as well as beam's-eye-view conformal treatment plans. Plan comparisons were accomplished through conventional qualitative review of two-dimensional (2D) dose distributions in conjunction with quantitative techniques, such as dose-volume histograms, dosimetric statistics, normal tissue complication probabilities, tumor control probabilities, and objective numerical scoring. Results: For small intracranial lesions, there is little difference between intensity-modulated conformal treatment planning and radiosurgery treatment planning in the conformation of high isodose lines with the target volume. However, stereotactic treatment planning provides a steeper dose gradient outside the target volume and, hence, a lower normal tissue toxicity index. For extracranial sites, objective numerical scores for beam's-eye-view and intensity-modulated conformal planning techniques are superior to scores for conventional treatment plans. The beam's-eye-view planning technique prevents geographic target misses and better excludes healthy tissues from the treatment portal. Compared with scores for the beam's-eye-view planning technique, scores for

  4. Experimental measurements of spatial dose distributions in radiosurgery treatments

    International Nuclear Information System (INIS)

    Avila-Rodriguez, M. A.; Rodriguez-Villafuerte, M.; Diaz-Perches, R.; Perez-Pastenes, M. A.

    2001-01-01

    The measurement of stereotactic radiosurgery dose distributions requires an integrating, high-resolution dosimeter capable of providing a spatial map of absorbed dose. This paper describes the use of a commercial radiochromic dye film (GafChromic MD-55-2) to measure radiosurgery dose distributions with 6 MV X-rays in a head phantom. The response of the MD-55-2 was evaluated by digitizing and analyzing the films with conventional computer systems. Radiosurgery dose distributions were measured using the radiochromic film in a spherical acrylic phantom of 16 cm diameter undergoing a typical SRS treatment as a patient, and were compared with dose distributions provided by the treatment planning system. The comparison lead to mean radial differences of ±0.6 mm, ±0.9 mm, ±1.3 mm, ±1.9 mm, and ±2.8 mm, for the 80, 60, 50, 40, and 30% isodose curves, respectively. It is concluded that the radiochromic film is a convenient and useful tool for radiosurgery treatment planning validation

  5. Combined stereotactic biopsy and stepping-source interstitial irradiation of glioblastoma multiforme.

    Science.gov (United States)

    Brehmer, Stefanie; Guthier, Christian V; Clausen, Sven; Schneider, Frank; Schulte, Dirk-Michael; Benker, Matthias; Bludau, Frederic; Glatting, Gerhard; Marx, Alexander; Schmiedek, Peter; Hesser, Jürgen; Wenz, Frederik; Giordano, Frank A

    2018-04-01

    Patients diagnosed with glioblastoma multiforme receiving stereotactic biopsy only either due to tumor localization or impaired clinical status face a devastating prognosis with very short survival times. One strategy to provide an initial cytoreductive and palliative therapy at the time of the stereotactic biopsy is interstitial irradiation through the pre-defined trajectory of the biopsy channel. We designed a novel treatment planning system and evaluated the treatment potential of a fixed-source and a stepping-source algorithm for interstitial radiosurgery on non-spherical glioblastoma in direct adjacency to risk structures. Using both setups, we show that radiation doses delivered to 100% of the gross tumor volume shifts from sub-therapeutic (10-12 Gy) to sterilizing single doses (25-30 Gy) when using the stepping source algorithm due to improved sparing of organs-at-risk. Specifically, the maximum doses at the brain stem were 100% of the PTV dose when a fixed central source and 38% when a stepping-source algorithm was used. We also demonstrated precision of intracranial target points and stability of superficial and deep trajectories using both a phantom and a body donor study. Our setup now for the first time provides a basis for a clinical proof-of-concept trial and may widen palliation options for patients with limited life expectancy that should not undergo time-consuming therapies.

  6. Initial clinical results of linac stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) for pituitary adenomas

    International Nuclear Information System (INIS)

    Mitsumori, Michihide; Shrieve, Dennis C.; Alexander, Eben; Kaiser, Ursula B.; Richardson, Gary E.; McL Black, Peter; Loeffler, Jay S.

    1997-01-01

    Purpose: To evaluate the initial clinical results of stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (SRT) for pituitary adenomas with regard to tumor control and toxicity of the treatment, thus evaluate the feasibility of these technique for the treatment of pituitary adenomas. Subjects and Methods: 48 patients with either inoperable, recurrent or residual pituitary adenoma who underwent either SRS or SRT at the Brigham and Women's Hospital between 9/89 and 9/95 were analyzed. Of these, 18 received treatment with SRS, and 30 received SRT. SRS was contraindicated for the patients in whom the minimal distance of the target and optic chiasm or optic nerve was less than 5 mm. Patient characteristics were similar in the two groups, with the exception of tumor volume and previous irradiation. Median tumor volumes were 1.8 cm 3 and 7.7 cm 3 for SRS and SRT, respectively. Three of the SRS and none of the SRT patients had a history of previous external radiation therapy. Both SRS and SRT were performed by the use of dedicated stereotactic 6-MV linear accelerator with a treatment plan designed using a dedicated software. Doses were prescribed to the isodose distribution that covered the identified target. Dose and normalization used for SRS varied from 1000 cGy at 85 % isodose line to 1800 cGy at 80 % isodose line. For SRT patients, total dose of 4500 cGy was normalized at 90 or 95 % isodose line and this was delivered in 25 fractions of 180 cGy daily dose. Results: Local control: There was 1 case of local failure in each of SRS and SRT series (median follow up 42.5 months and 22 month, respectively). CNS adverse effects: There were 3 SRS cases in whom a ring enhancement in the temporal lobe was observed in follow-up MRI. (median follow up 32 months). Of these, one resolved spontaneously, whereas the other 2 lesion persisted and considered to be radiation necrosis. None of them required surgical intervention to date. These were observed in the

  7. Repeated delayed onset cerebellar radiation injuries after linear accelerator-based stereotactic radiosurgery for vestibular schwannoma. Case report

    International Nuclear Information System (INIS)

    Ujifuku, Kenta; Matsuo, Takayuki; Toyoda, Keisuke

    2012-01-01

    A 63-year-old woman presented with right hearing disturbance and vertigo. Magnetic resonance (MR) imaging revealed the presence of right vestibular schwannoma (VS). Stereotactic radiosurgery (SRS) was performed with a tumor marginal dose of 14 Gy using two isocenters. She was followed up clinically and neuroradiologically using three-dimensional spoiled gradient-echo MR imaging. She experienced temporal neurological deterioration due to peritumoral edema in her right cerebellar peduncle and pons for a few months beginning 1.5 years after SRS, when she experienced transient right facial dysesthesia and hearing deterioration. Ten years after SRS, the patient presented with sudden onset of vertigo, gait disturbance, diplopia, dysarthria, and nausea. MR imaging demonstrated a new lesion in the right cerebellar peduncle, which was diagnosed as radiation-induced stroke. The patient was followed up conservatively and her symptoms disappeared within a few months. Multiple delayed onset radiation injuries are possible sequelae of SRS for VS. (author)

  8. Verification of the linac isocenter for stereotactic radiosurgery using cine-EPID imaging and arc delivery

    International Nuclear Information System (INIS)

    Rowshanfarzad, Pejman; Sabet, Mahsheed; O' Connor, Daryl J.; Greer, Peter B.

    2011-01-01

    Purpose:Verification of the mechanical isocenter position is required as part of comprehensive quality assurance programs for stereotactic radiosurgery/radiotherapy (SRS/SRT) treatments. Several techniques have been proposed for this purpose but each of them has certain drawbacks. In this paper, a new efficient and more comprehensive method using cine-EPID images has been introduced for automatic verification of the isocenter with sufficient accuracy for stereotactic applications. Methods: Using a circular collimator fixed to the gantry head to define the field, EPID images of a Winston-Lutz phantom were acquired in cine-imaging mode during 360 deg. gantry rotations. A robust matlab code was developed to analyze the data by finding the center of the field and the center of the ball bearing shadow in each image with sub-pixel accuracy. The distance between these two centers was determined for every image. The method was evaluated by comparison to results of a mechanical pointer and also by detection of a manual shift applied to the phantom position. The repeatability and reproducibility of the method were tested and it was also applied to detect couch and collimator wobble during rotation. Results:The accuracy of the algorithm was 0.03 ± 0.02 mm. The repeatability was less than 3 μm and the reproducibility was less than 86 μm. The time elapsed for the analysis of more than 100 cine images of Varian aS1000 and aS500 EPIDs were ∼65 and 20 s, respectively. Processing of images taken in integrated mode took 0.1 s. The output of the analysis software is printable and shows the isocenter shifts as a function of angle in both in-plane and cross-plane directions. It gives warning messages where the shifts exceed the criteria for SRS/SRT and provides useful data for the necessary adjustments in the system including bearing system and/or room lasers. Conclusions: The comprehensive method introduced in this study uses cine-images, is highly accurate, fast, and independent

  9. Verification of the linac isocenter for stereotactic radiosurgery using cine-EPID imaging and arc delivery

    Energy Technology Data Exchange (ETDEWEB)

    Rowshanfarzad, Pejman; Sabet, Mahsheed; O' Connor, Daryl J.; Greer, Peter B. [School of Mathematical and Physical Sciences, University of Newcastle, Newcastle, New South Wales 2308 (Australia); Department of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, New South Wales 2310, Australia and School of Mathematical and Physical Sciences, University of Newcastle, Newcastle, New South Wales 2308 (Australia)

    2011-07-15

    Purpose:Verification of the mechanical isocenter position is required as part of comprehensive quality assurance programs for stereotactic radiosurgery/radiotherapy (SRS/SRT) treatments. Several techniques have been proposed for this purpose but each of them has certain drawbacks. In this paper, a new efficient and more comprehensive method using cine-EPID images has been introduced for automatic verification of the isocenter with sufficient accuracy for stereotactic applications. Methods: Using a circular collimator fixed to the gantry head to define the field, EPID images of a Winston-Lutz phantom were acquired in cine-imaging mode during 360 deg. gantry rotations. A robust matlab code was developed to analyze the data by finding the center of the field and the center of the ball bearing shadow in each image with sub-pixel accuracy. The distance between these two centers was determined for every image. The method was evaluated by comparison to results of a mechanical pointer and also by detection of a manual shift applied to the phantom position. The repeatability and reproducibility of the method were tested and it was also applied to detect couch and collimator wobble during rotation. Results:The accuracy of the algorithm was 0.03 {+-} 0.02 mm. The repeatability was less than 3 {mu}m and the reproducibility was less than 86 {mu}m. The time elapsed for the analysis of more than 100 cine images of Varian aS1000 and aS500 EPIDs were {approx}65 and 20 s, respectively. Processing of images taken in integrated mode took 0.1 s. The output of the analysis software is printable and shows the isocenter shifts as a function of angle in both in-plane and cross-plane directions. It gives warning messages where the shifts exceed the criteria for SRS/SRT and provides useful data for the necessary adjustments in the system including bearing system and/or room lasers. Conclusions: The comprehensive method introduced in this study uses cine-images, is highly accurate, fast, and

  10. A high-precision system for conformal intracranial radiotherapy

    International Nuclear Information System (INIS)

    Tome, Wolfgang A.; Meeks, Sanford L.; Buatti, John M.; Bova, Francis J.; Friedman, William A.; Li Zuofeng

    2000-01-01

    Purpose: Currently, optimally precise delivery of intracranial radiotherapy is possible with stereotactic radiosurgery and fractionated stereotactic radiotherapy. We report on an optimally precise optically guided system for three-dimensional (3D) conformal radiotherapy using multiple noncoplanar fixed fields. Methods and Materials: The optically guided system detects infrared light emitting diodes (IRLEDs) attached to a custom bite plate linked to the patient's maxillary dentition. The IRLEDs are monitored by a commercially available stereo camera system, which is interfaced to a personal computer. An IRLED reference is established with the patient at the selected stereotactic isocenter, and the computer reports the patient's current position based on the location of the IRLEDs relative to this reference position. Using this readout from the computer, the patient may be dialed directly to the desired position in stereotactic space. The patient is localized on the first day and a reference file is established for 5 different couch positions. The patient's image data are then imported into a commercial convolution-based 3D radiotherapy planning system. The previously established isocenter and couch positions are then used as a template upon which to design a conformal 3D plan with maximum beam separation. Results: The use of the optically guided system in conjunction with noncoplanar radiotherapy treatment planning using fixed fields allows the generation of highly conformal treatment plans that exhibit a high degree of dose homogeneity and a steep dose gradient. To date, this approach has been used to treat 28 patients. Conclusion: Because IRLED technology improves the accuracy of patient localization relative to the linac isocenter and allows real-time monitoring of patient position, one can choose treatment-field margins that only account for beam penumbra and image resolution without adding margin to account for larger and poorly defined setup uncertainty. This

  11. Stereotactic radiosurgery for treatment of brain metastases. A report of the DEGRO Working Group on Stereotactic Radiotherapy

    International Nuclear Information System (INIS)

    Kocher, Martin; Wittig, Andrea; Piroth, Marc Dieter; Treuer, Harald; Ruge, Maximilian; Seegenschmiedt, Heinrich; Grosu, Anca-Ligia; Guckenberger, Matthias

    2014-01-01

    This report from the Working Group on Stereotaktische Radiotherapie of the German Society of Radiation Oncology (Deutsche Gesellschaft fuer Radioonkologie, DEGRO) provides recommendations for the use of stereotactic radiosurgery (SRS) on patients with brain metastases. It considers existing international guidelines and details them where appropriate. The main recommendations are: Patients with solid tumors except germ cell tumors and small-cell lung cancer with a life expectancy of more than 3 months suffering from a single brain metastasis of less than 3 cm in diameter should be considered for SRS. Especially when metastases are not amenable to surgery, are located in the brain stem, and have no mass effect, SRS should be offered to the patient. For multiple (two to four) metastases - all less than 2.5 cm in diameter - in patients with a life expectancy of more than 3 months, SRS should be used rather than whole-brain radiotherapy (WBRT). Adjuvant WBRT after SRS for both single and multiple (two to four) metastases increases local control and reduces the frequency of distant brain metastases, but does not prolong survival when compared with SRS and salvage treatment. As WBRT carries the risk of inducing neurocognitive damage, it seems reasonable to withhold WBRT for as long as possible. A single (marginal) dose of 20 Gy is a reasonable choice that balances the effect on the treated lesion (local control, partial remission) against the risk of late side effects (radionecrosis). Higher doses (22-25 Gy) may be used for smaller ( [de

  12. Gamma Knife Radiosurgery for Patients With Nonfunctioning Pituitary Adenomas: Results From a 15-Year Experience

    International Nuclear Information System (INIS)

    Pollock, Bruce E.; Cochran, Joseph; Natt, Neena; Brown, Paul D.; Erickson, Dana; Link, Michael J.; Garces, Yolanda I.; Foote, Robert L.; Stafford, Scott L.; Schomberg, Paula J.

    2008-01-01

    Purpose: To evaluate the efficacy and complications of stereotactic radiosurgery for patients with nonfunctioning pituitary adenomas (NFA). Methods and Materials: This was a retrospective review of 62 patients with NFA undergoing radiosurgery between 1992 and 2004, of whom 59 (95%) underwent prior tumor resection. The median treatment volume was 4.0 cm 3 (range, 0.8-12.9). The median treatment dose to the tumor margin was 16 Gy (range, 11-20). The median maximum point dose to the optic apparatus was 9.5 Gy (range, 5.0-12.6). The median follow-up period after radiosurgery was 64 months (range, 23-161). Results: Tumor size decreased for 37 patients (60%) and remained unchanged for 23 patients (37%). Two patients (3%) had tumor growth outside the prescribed treatment volume and required additional treatment (fractionated radiation therapy, n = 1; repeat radiosurgery, n 1). Tumor growth control was 95% at 3 and 7 years after radiosurgery. Eleven (27%) of 41 patients with normal (n = 30) or partial (n = 11) anterior pituitary function before radiosurgery developed new deficits at a median of 24 months after radiosurgery. The risk of developing new anterior pituitary deficits at 5 years was 32%. The 5-year risk of developing new anterior pituitary deficits was 18% for patients with a tumor volume of ≤4.0 cm 3 compared with 58% for patients with a tumor volume >4.0 cm 3 (risk ratio 4.5; 95% confidence interval = 1.3-14.9, p = 0.02). No patient had a decline in visual function. Conclusions: Stereotactic radiosurgery is effective in the management of patients with residual or recurrent NFA, although longer follow-up is needed to evaluate long-term outcomes. The primary complication is hypopituitarism, and the risk of developing new anterior pituitary deficits correlates with the size of the irradiated tumor

  13. Compensating for Quasi-periodic Motion in Robotic Radiosurgery

    CERN Document Server

    Ernst, Floris

    2012-01-01

    Compensating for Quasi-periodic Motion in Robotic Radiosurgery outlines the techniques needed to accurately track and compensate for respiratory and pulsatory motion during robotic radiosurgery. The algorithms presented within the book aid in the treatment of tumors that move during respiration. In Chapters 1 and 2,  the book introduces the concept of stereotactic body radiation therapy, motion compensation strategies and the clinical state-of-the-art. In Chapters 3 through 5, the author describes and evaluates new methods for motion prediction, for correlating external motion to internal organ motion, and for the evaluation of these algorithms’ output based on an unprecedented amount of real clinical data. Finally, Chapter 6 provides a brief introduction into currently investigated, open questions and further fields of research. Compensating for Quasi-periodic Motion in Robotic Radiosurgery targets researchers working in the related fields of surgical oncology, artificial intelligence, robotics and more. ...

  14. Radiosurgery for brain metastases: a score index for predicting prognosis

    International Nuclear Information System (INIS)

    Weltman, Eduardo; Salvajoli, Joao Victor; Brandt, Reynaldo Andre; Morais Hanriot, Rodrigo de; Prisco, Flavio Eduardo; Cruz, Jose Carlos; Oliveira Borges, Sandra Regina de; Wajsbrot, Dalia Ballas

    2000-01-01

    Purpose: To analyze a prognostic score index for patients with brain metastases submitted to stereotactic radiosurgery (the Score Index for Radiosurgery in Brain Metastases [SIR]). Methods and Materials: Actuarial survival of 65 brain metastases patients treated with radiosurgery between July 1993 and December 1997 was retrospectively analyzed. Prognostic factors included age, Karnofsky performance status (KPS), extracranial disease status, number of brain lesions, largest brain lesion volume, lesions site, and receiving or not whole brain irradiation. The SIR was obtained through summation of the previously noted first five prognostic factors. Kaplan-Meier actuarial survival curves for all prognostic factors, SIR, and recursive partitioning analysis (RPA) (RTOG prognostic score) were calculated. Survival curves of subsets were compared by log-rank test. Application of the Cox model was utilized to identify any correlation between prognostic factors, prognostic scores, and survival. Results: Median overall survival from radiosurgery was 6.8 months. Utilizing univariate analysis, extracranial disease status, KPS, number of brain lesions, largest brain lesion volume, RPA, and SIR were significantly correlated with prognosis. Median survival for the RPA classes 1, 2, and 3 was 20.19 months, 7.75 months, and 3.38 months respectively (p = 0.0131). Median survival for patients, grouped under SIR from 1 to 3, 4 to 7, and 8 to 10, was 2.91 months, 7.00 months, and 31.38 months respectively (p = 0.0001). Using the Cox model, extracranial disease status and KPS demonstrated significant correlation with prognosis (p 0.0001 and 0.0004 respectively). Multivariate analysis also demonstrated significance for SIR and RPA when tested individually (p = 0.0001 and 0.0040 respectively). Applying the Cox Model to both SIR and RPA, only SIR reached independent significance (p = 0.0004). Conclusions: Systemic disease status, KPS, SIR, and RPA are reliable prognostic factors for patients

  15. Characteristics of Philips SL-20 linear accelerator used for stereotactic radiosurgery/radiotherapy

    International Nuclear Information System (INIS)

    D'Souza, Harold; Ganesh, T.; Joshi, R.C.; Julka, P.K.; Rath, G.K.; Chander, Subhash; Pant, G.S.

    2002-01-01

    Commissioning of a stereotactic radiosurgery/stereotactic radiotherapy (SRS/SRT) facility on a modified linear accelerator requires validation of mechanical parameters and establishment of parameters, such as tissue maximum ratio (TMR), relative output factors (OF), and off axis ratios (OAR). The mechanical and beam characteristics of Philips SL-20 linear accelerator modified for SRS/SRT were evaluated and presented. The SRS/SRT procedure carried on Philips SL-20 linear accelerator with Brown-Robert-Wells (BRW) and relocatable Gill-Thomas-Cosman (GTC) head frames along with the Radionics planning system was evaluated. The tertiary collimator consists of the actual treatment cones and their sizes vary from 12.5 mm to 40 mm diameter. The alignment of the auxillary collimator axis with mechanical axes and stability of the isocenter of Philips SL-20 machine was evaluated using Iso-Align device and mechanical isocenter standard (MIS). All the mechanical errors of the linear accelerator were within 1 mm, except the stability of the isocenter while rotating the couch. Alignment of auxiliary collimator axis with the central axis, gantry and couch axes were achieved. The TMR, OF and OAR for 6 MV x-rays from Philips SL-20 linear accelerator for different cone sizes were deduced using a Multidata water phantom with 0.015 cc ion chamber. The difference between 50% width of profiles in two major axes (x and y) were within ± 0.4 mm. The cone dimensions were accurate up to 0.7 mm. The penumbra width for different cones varies from 3.1 mm to 3.5 mm. Dose linearity of the monitoring system was ≤ 1% above 5 MU. The mechanical and beam characteristics including dose linearity of the SL-20 machine are presented. The beam characteristics of this machine are comparable with the other modified linear accelerators for SRS/SRT. The shift of isocenter during rotation of couch can be nullified by fine adjusting laser target localizing frame to the laser position using micrometer screws

  16. Characteristics of a dedicated linear accelerator-based stereotactic radiosurgery-radiotherapy unit

    International Nuclear Information System (INIS)

    Das, Indra J.; Downes, M. Beverly; Corn, Benjamin W.; Curran, Walter J.; Werner-Wasik, M.; Andrews, David W.

    1996-01-01

    A stereotactic radiosurgery and radiotherapy (SRS/SRT) system on a dedicated Varian Clinac-600SR linear accelerator with Brown-Roberts-Wells and Gill-Thomas-Cosman relocatable frames along with the Radionics (RSA) planning system is evaluated. The Clinac-600SR has a single 6-MV beam with the same beam characteristics as that of the mother unit, the Clinac-600C. The primary collimator is a fixed cone projecting to a 10-cm diameter at isocenter. The secondary collimator is a heavily shielded cylindrical collimator attached to the face plate of the primary collimator. The tertiary collimation consists of the actual treatment cones. The cone sizes vary from 12.5 to 40.0 mm diameter. The mechanical stability of the entire system was verified. The variations in isocenter position with table, gantry, and collimator rotation were found to be <0.5 mm with a compounded accuracy of ≤ 1.0 mm. The radiation leakage under the cones was < 1% measured at a depth of 5 cm in a phantom. The beam profiles of all cones in the x and y directions were within ±0.5 mm and match with the physical size of the cone. The dosimetric data such as tissue maximum ratio, off-axis ratio, and cone factor were taken using film, diamond detector, and ion chambers. The mechanical and dosimetric characteristics including dose linearity of this unit are presented and found to be suitable for SRS/SRT. The difficulty in absolute dose measurement for small cone is discussed

  17. Linac-based radiosurgery of cerebral melanoma metastases. Analysis of 122 metastases treated in 64 patients

    International Nuclear Information System (INIS)

    Herfarth, K.K.; Pirzkall, A.; Izwekowa, O.; Wannenmacher, M.; Thilmann, C.; Debus, J.; Delorme, S.; Hofmann, U.; Schadendorf, D.; Zierhut, D.

    2003-01-01

    Purpose: Stereotactic radiosurgery is an alternative option to neurosurgical excision in the management of patients with brain metastases. We retrospectively analyzed patients with brain metastases of malignant melanoma who were treated at our institution for outcome and prognostic factors. Patients and Methods: 64 patients with 122 cerebral metastases were treated with stereotactic radiosurgery between 1986 and 2000. Twelve patients (19%) showed neurologic symptoms at the time of treatment, and 46 patients (72%) had extracerebral tumor manifestation at that time. The median dose to the 80% isodose line, prescribed to encompass the tumor margin, was 20 Gy (range, 15-22 Gy). Results: Neurologic symptoms improved in five of twelve symptomatic patients. 41 patients remained asymptomatic or unchanged in their neurologic symptoms. Only five patients (8%) temporarily worsened neurologically after therapy despite no signs of tumor progression. With a mean follow-up time of 9.4 months, actuarial local control was 81% after 1 year. There was a statistically significant dose and size dependency of local tumor control. Median actuarial survival after treatment was 10.6 months. Patients without extracerebral tumor manifestation showed a superior survival (p = 0.04). Conclusions: Despite high local tumor control rates, the prognosis of patients with cerebral metastases of malignant melanoma remains poor. Stereotactic radiosurgery has the potential of stabilizing or improving neurologic symptoms in these patients in a palliative setting. (orig.)

  18. Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI

    International Nuclear Information System (INIS)

    Schad, L.R.; Bock, M.; Baudendistel, K.; Essig, M.; Debus, J.; Knopp, M.V.; Engenhart, R.; Lorenz, W.J.

    1996-01-01

    The authors report the sterotactic correlation of different MRI-techniques [MR angiography (MRA), MRI, blood bolus tagging (STAR), and functional MRI] in 10 patients with cerebral arteriovenous malformations (AVM) and its application in precision radiotherapy planning. The patient's head was fixed in a stereotactic localization system. By phantom measurements different materials (steel, aluminium, titanium, plastic, wood, ceramics) used for the stereotactic system were tested for mechanical stability and geometrical MR image distortion. All metallic stereotactic rings led to a more or less dramatic geometrical distortion and signal cancellation in the MR images. The best properties - nearly no distortion and high mechanical stability - are provided by a ceramic ring. If necessary, the remaining geometrical MR image distortion can be 'corrected' by calculations based on modeling the distortion as a fourth-order 2D-polynomial. Using this method multimodality matching can be performed automatically as long as all images are acquired in the same examination and the patient is sufficiently immobilized. Precise definition of the target volume could be performed by the radiotherapist either directly in MR images or in calculated projection MR angiograms. As a result, information about the hemodynamics of the AVM was provided by a 3D-phase-contrast flow measurement and a dynamic MRA with the STAR technique leading to an improved definition of the size of the nidus, and the pattern of the venous drainage. In addition, functional MRI was performed in patients with lesions close to the primary motor cortex area leading to an improved definition of structures at risk for high-dose application in radiosurgery. (orig./MG)

  19. Gamma Knife Stereotactic Radiosurgery as Salvage Therapy After Failure of Whole-Brain Radiotherapy in Patients With Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Harris, Sunit; Chan, Michael D.; Lovato, James F.; Ellis, Thomas L.; Tatter, Stephen B.; Bourland, J. Daniel; Munley, Michael T.; Guzman, Allan F. de; Shaw, Edward G.; Urbanic, James J.; McMullen, Kevin P.

    2012-01-01

    Purpose: Radiosurgery has been successfully used in selected cases to avoid repeat whole-brain irradiation (WBI) in patients with multiple brain metastases of most solid tumor histological findings. Few data are available for the use of radiosurgery for small-cell lung cancer (SCLC). Methods and Materials: Between November 1999 and June 2009, 51 patients with SCLC and previous WBI and new brain metastases were treated with GammaKnife stereotactic radiosurgery (GKSRS). A median dose of 18 Gy (range, 10–24 Gy) was prescribed to the margin of each metastasis. Patients were followed with serial imaging. Patient electronic records were reviewed to determine disease-related factors and clinical outcomes after GKSRS. Local and distant brain failure rates, overall survival, and likelihood of neurologic death were determined based on imaging results. The Kaplan-Meier method was used to determine survival and local and distant brain control. Cox proportional hazard regression was performed to determine strength of association between disease-related factors and survival. Results: Median survival time for the entire cohort was 5.9 months. Local control rates at 1 and 2 years were 57% and 34%, respectively. Distant brain failure rates at 1 and 2 years were 58% and 75%, respectively. Fifty-three percent of patients ultimately died of neurologic death. On multivariate analysis, patients with stable (hazard ratio [HR] = 2.89) or progressive (HR = 6.98) extracranial disease (ECD) had worse overall survival than patients without evidence of ECD (p = 0.00002). Concurrent chemotherapy improved local control (HR = 89; p = 0.006). Conclusions: GKSRS represents a feasible salvage option in patients with SCLC and brain metastases for whom previous WBI has failed. The status of patients’ ECD is a dominant factor predictive of overall survival. Local control may be inferior to that seen with other cancer histological results, although the use of concurrent chemotherapy may help to

  20. Gamma Knife Stereotactic Radiosurgery as Salvage Therapy After Failure of Whole-Brain Radiotherapy in Patients With Small-Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Sunit [Department of Radiation Oncology, Wake Forest University, Winston-Salem, North Carolina (United States); Chan, Michael D., E-mail: mchan@wfubmc.edu [Department of Radiation Oncology, Wake Forest University, Winston-Salem, North Carolina (United States); Lovato, James F. [Division of Public Health Sciences, Wake Forest University, Winston-Salem, North Carolina (United States); Ellis, Thomas L.; Tatter, Stephen B. [Department of Neurosurgery, Wake Forest University, Winston-Salem, North Carolina (United States); Bourland, J. Daniel; Munley, Michael T.; Guzman, Allan F. de; Shaw, Edward G.; Urbanic, James J.; McMullen, Kevin P. [Department of Radiation Oncology, Wake Forest University, Winston-Salem, North Carolina (United States)

    2012-05-01

    Purpose: Radiosurgery has been successfully used in selected cases to avoid repeat whole-brain irradiation (WBI) in patients with multiple brain metastases of most solid tumor histological findings. Few data are available for the use of radiosurgery for small-cell lung cancer (SCLC). Methods and Materials: Between November 1999 and June 2009, 51 patients with SCLC and previous WBI and new brain metastases were treated with GammaKnife stereotactic radiosurgery (GKSRS). A median dose of 18 Gy (range, 10-24 Gy) was prescribed to the margin of each metastasis. Patients were followed with serial imaging. Patient electronic records were reviewed to determine disease-related factors and clinical outcomes after GKSRS. Local and distant brain failure rates, overall survival, and likelihood of neurologic death were determined based on imaging results. The Kaplan-Meier method was used to determine survival and local and distant brain control. Cox proportional hazard regression was performed to determine strength of association between disease-related factors and survival. Results: Median survival time for the entire cohort was 5.9 months. Local control rates at 1 and 2 years were 57% and 34%, respectively. Distant brain failure rates at 1 and 2 years were 58% and 75%, respectively. Fifty-three percent of patients ultimately died of neurologic death. On multivariate analysis, patients with stable (hazard ratio [HR] = 2.89) or progressive (HR = 6.98) extracranial disease (ECD) had worse overall survival than patients without evidence of ECD (p = 0.00002). Concurrent chemotherapy improved local control (HR = 89; p = 0.006). Conclusions: GKSRS represents a feasible salvage option in patients with SCLC and brain metastases for whom previous WBI has failed. The status of patients' ECD is a dominant factor predictive of overall survival. Local control may be inferior to that seen with other cancer histological results, although the use of concurrent chemotherapy may help to

  1. Effect of the embolization material in the dose calculation for stereotactic radiosurgery of arteriovenous malformations

    International Nuclear Information System (INIS)

    Galván de la Cruz, Olga Olinca; Lárraga-Gutiérrez, José Manuel; Moreno-Jiménez, Sergio; García-Garduño, Olivia Amanda; Celis, Miguel Angel

    2013-01-01

    It is reported in the literature that the material used in an embolization of an arteriovenous malformation (AVM) can attenuate the radiation beams used in stereotactic radiosurgery (SRS) up to 10% to 15%. The purpose of this work is to assess the dosimetric impact of this attenuating material in the SRS treatment of embolized AVMs, using Monte Carlo simulations assuming clinical conditions. A commercial Monte Carlo dose calculation engine was used to recalculate the dose distribution of 20 AVMs previously planned with a pencil beam dose calculation algorithm. Dose distributions were compared using the following metrics: average, minimal and maximum dose of AVM, and 2D gamma index. The effect in the obliteration rate was investigated using radiobiological models. It was found that the dosimetric impact of the embolization material is less than 1.0 Gy in the prescription dose to the AVM for the 20 cases studied. The impact in the obliteration rate is less than 4.0%. There is reported evidence in the literature that embolized AVMs treated with SRS have low obliteration rates. This work shows that there are dosimetric implications that should be considered in the final treatment decisions for embolized AVMs

  2. Effect of the embolization material in the dose calculation for stereotactic radiosurgery of arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Galván de la Cruz, Olga Olinca [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico); Lárraga-Gutiérrez, José Manuel, E-mail: jlarraga@innn.edu.mx [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico); Laboratorio de Física Médica, Instituto Nacional de Neurología y Neurocirugía (Mexico); Moreno-Jiménez, Sergio [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico); García-Garduño, Olivia Amanda [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico); Laboratorio de Física Médica, Instituto Nacional de Neurología y Neurocirugía (Mexico); Celis, Miguel Angel [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico)

    2013-07-01

    It is reported in the literature that the material used in an embolization of an arteriovenous malformation (AVM) can attenuate the radiation beams used in stereotactic radiosurgery (SRS) up to 10% to 15%. The purpose of this work is to assess the dosimetric impact of this attenuating material in the SRS treatment of embolized AVMs, using Monte Carlo simulations assuming clinical conditions. A commercial Monte Carlo dose calculation engine was used to recalculate the dose distribution of 20 AVMs previously planned with a pencil beam dose calculation algorithm. Dose distributions were compared using the following metrics: average, minimal and maximum dose of AVM, and 2D gamma index. The effect in the obliteration rate was investigated using radiobiological models. It was found that the dosimetric impact of the embolization material is less than 1.0 Gy in the prescription dose to the AVM for the 20 cases studied. The impact in the obliteration rate is less than 4.0%. There is reported evidence in the literature that embolized AVMs treated with SRS have low obliteration rates. This work shows that there are dosimetric implications that should be considered in the final treatment decisions for embolized AVMs.

  3. Radiosurgery for pituitary adenomas; Radiocirurgia nos adenomas hipofisarios

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Douglas Guedes de; Salvajoli, Joao Victor; Canteras, Miguel Montes; Cecilio, Soraya A. Jorge [Instituto de Radiocirurgia Neurologica, Sao Paulo, SP (Brazil)]. E-mail: dougguedes@uol.com.br

    2006-12-15

    Pituitary adenomas represent nearly 15% of all intracranial tumors. Multimodal treatment includes microsurgery, medical management and radiotherapy. Microsurgery is the primary recommendation for nonfunctioning and most of functioning adenomas, except for prolactinomas that are usually managed with dopamine agonist drugs. However, about 30% of patients require additional treatment after microsurgery for recurrent or residual tumors. In these cases, fractionated radiation therapy has been the traditional treatment. More recently, radiosurgery has been established as a treatment option. Radiosurgery allows the delivery of prescribed dose with high precision strictly to the target and spares the surrounding tissues. Therefore, the risks of hypopituitarism, visual damage and vasculopathy are significantly lower. Furthermore, the latency of the radiation response after radiosurgery is substantially shorter than that of fractionated radiotherapy. The goal of this review is to define the efficacy, safety and role of radiosurgery for treatment of pituitary adenomas and to present the preliminary results of our institution. (author)

  4. Vorinostat and Concurrent Stereotactic Radiosurgery for Non-Small Cell Lung Cancer Brain Metastases: A Phase 1 Dose Escalation Trial.

    Science.gov (United States)

    Choi, Clara Y H; Wakelee, Heather A; Neal, Joel W; Pinder-Schenck, Mary C; Yu, Hsiang-Hsuan Michael; Chang, Steven D; Adler, John R; Modlin, Leslie A; Harsh, Griffith R; Soltys, Scott G

    2017-09-01

    To determine the maximum tolerated dose (MTD) of vorinostat, a histone deacetylase inhibitor, given concurrently with stereotactic radiosurgery (SRS) to treat non-small cell lung cancer (NSCLC) brain metastases. Secondary objectives were to determine toxicity, local failure, distant intracranial failure, and overall survival rates. In this multicenter study, patients with 1 to 4 NSCLC brain metastases, each ≤2 cm, were enrolled in a phase 1, 3 + 3 dose escalation trial. Vorinostat dose levels were 200, 300, and 400 mg orally once daily for 14 days. Single-fraction SRS was delivered on day 3. A dose-limiting toxicity (DLT) was defined as any Common Terminology Criteria for Adverse Events version 3.0 grade 3 to 5 acute nonhematologic adverse event related to vorinostat or SRS occurring within 30 days. From 2009 to 2014, 17 patients were enrolled and 12 patients completed study treatment. Because no DLTs were observed, the MTD was established as 400 mg. Acute adverse events were reported by 10 patients (59%). Five patients discontinued vorinostat early and withdrew from the study. The most common reasons for withdrawal were dyspnea (n=2), nausea (n=1), and fatigue (n=2). With a median follow-up of 12 months (range, 1-64 months), Kaplan-Meier overall survival was 13 months. There were no local failures. One patient (8%) at the 400-mg dose level with a 2.0-cm metastasis developed histologically confirmed grade 4 radiation necrosis 2 months after SRS. The MTD of vorinostat with concurrent SRS was established as 400 mg. Although no DLTs were observed, 5 patients withdrew before completing the treatment course, a result that emphasizes the need for supportive care during vorinostat administration. There were no local failures. A larger, randomized trial may evaluate both the tolerability and potential local control benefit of vorinostat concurrent with SRS for brain metastases. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. SU-F-T-566: Absolute Film Dosimetry for Stereotactic Radiosurgery and Stereotactic Body Radiotherapy Quality Assurance Using Gafchromic EBT3 Films

    Energy Technology Data Exchange (ETDEWEB)

    Wen, N; Lu, S; Qin, Y; Huang, Y; Zhao, B; Liu, C; Chetty, I [Henry Ford Health System, Detroit, MI (United States)

    2016-06-15

    Purpose: To evaluate the dosimetric uncertainty associated with Gafchromic (EBT3) films and establish an absolute dosimetry protocol for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT). Methods: EBT3 films were irradiated at each of seven different dose levels between 1 and 15 Gy with open fields, and standard deviations of dose maps were calculated at each color channel for evaluation. A scanner non-uniform response correction map was built by registering and comparing film doses to the reference diode array-based dose map delivered with the same doses. To determine the temporal dependence of EBT3 films, the average correction factors of different dose levels as a function of time were evaluated up to four days after irradiation. An integrated film dosimetry protocol was developed for dose calibration, calibration curve fitting, dose mapping, and profile/gamma analysis. Patient specific quality assurance (PSQA) was performed for 93 SRS/SBRT treatment plans. Results: The scanner response varied within 1% for the field sizes less than 5 × 5 cm{sup 2}, and up to 5% for the field sizes of 10 × 10 cm{sup 2}. The scanner correction method was able to remove visually evident, irregular detector responses found for larger field sizes. The dose response of the film changed rapidly (∼10%) in the first two hours and plateaued afterwards, ∼3% change between 2 and 24 hours. The mean uncertainties (mean of the standard deviations) were <0.5% over the dose range 1∼15Gy for all color channels for the OD response curves. The percentage of points passing the 3%/1mm gamma criteria based on absolute dose analysis, averaged over all tests, was 95.0 ± 4.2. Conclusion: We have developed an absolute film dose dosimetry protocol using EBT3 films. The overall uncertainty has been established to be approximately 1% for SRS and SBRT PSQA. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.

  6. Stereotactic Radiosurgery in the Management of Patients With Brain Metastases of Non-Small Cell Lung Cancer: Indications, Decision Tools and Future Directions

    Directory of Open Access Journals (Sweden)

    Dianne Hartgerink

    2018-05-01

    Full Text Available Brain metastases (BM frequently occur in non-small cell lung cancer (NSCLC patients. Most patients with BM have a limited life expectancy, measured in months. Selected patients may experience a very long progression-free survival, for example, patients with a targetable driver mutation. Traditionally, whole-brain radiotherapy (WBRT has been the cornerstone of the treatment, but its indication is a matter of debate. A randomized trial has shown that for patients with a poor prognosis, WBRT does not add quality of life (QoL nor survival over the best supportive care. In recent decades, stereotactic radiosurgery (SRS has become an attractive non-invasive treatment for patients with BM. Only the BM is irradiated to an ablative dose, sparing healthy brain tissue. Intracranial recurrence rates decrease when WBRT is administered following SRS or resection but does not improve overall survival and comes at the expense of neurocognitive function and QoL. The downside of SRS compared with WBRT is a risk of radionecrosis (RN and a higher risk of developing new BM during follow-up. Currently, SRS is an established treatment for patients with a maximum of four BM. Several promising strategies are currently being investigated to further improve the indication and outcome of SRS for patients with BM: the effectivity and safety of SRS in patients with more than four BM, combining SRS with systemic therapy such as targeted agents or immunotherapy, shared decision-making with SRS as a treatment option, and individualized isotoxic dose prescription to mitigate the risk of RN and further enhance local control probability of SRS. This review discusses the current indications of SRS and future directions of treatment for patients with BM of NSCLC with focus on the value of SRS.

  7. Frameless Angiogram-Based Stereotactic Radiosurgery for Treatment of Arteriovenous Malformations

    International Nuclear Information System (INIS)

    Lu Xingqi; Mahadevan, Anand; Mathiowitz, George; Lin, Pei-Jan P.; Thomas, Ajith; Kasper, Ekkehard M.; Floyd, Scott R.; Holupka, Edward; La Rosa, Salvatore; Wang, Frank; Stevenson, Mary Ann

    2012-01-01

    Purpose: Stereotactic radiosurgery (SRS) is an effective alternative to microsurgical resection or embolization for definitive treatment of arteriovenous malformations (AVMs). Digital subtraction angiography (DSA) is the gold standard for pretreatment diagnosis and characterization of vascular anatomy, but requires rigid frame (skull) immobilization when used in combination with SRS. With the advent of advanced proton and image-guided photon delivery systems, SRS treatment is increasingly migrating to frameless platforms, which are incompatible with frame-based DSA. Without DSA as the primary image, target definition may be less than optimal, in some cases precluding the ability to treat with a frameless system. This article reports a novel solution. Methods and Materials: Fiducial markers are implanted into the patient’s skull before angiography. Angiography is performed according to the standard clinical protocol, but, in contrast to the previous practice, without the rigid frame. Separate images of a specially designed localizer box are subsequently obtained. A target volume projected on DSA can be transferred to the localizer system in three dimensions, and in turn be transferred to multiple CT slices using the implanted fiducials. Combined with other imaging modalities, this “virtual frame” approach yields a highly precise treatment plan that can be delivered by frameless SRS technologies. Results: Phantom measurements for point and volume targets have been performed. The overall uncertainty of placing a point target to CT is 0.4 mm. For volume targets, deviation of the transformed contour from the target CT image is within 0.6 mm. The algorithm and software are robust. The method has been applied clinically, with reliable results. Conclusions: A novel and reproducible method for frameless SRS of AVMs has been developed that enables the use of DSA without the requirement for rigid immobilization. Multiple pairs of DSA can be used for better conformality

  8. Long-term Outcomes With Planned Multistage Reduced Dose Repeat Stereotactic Radiosurgery for Treatment of Inoperable High-Grade Arteriovenous Malformations: An Observational Retrospective Cohort Study.

    Science.gov (United States)

    Marciscano, Ariel E; Huang, Judy; Tamargo, Rafael J; Hu, Chen; Khattab, Mohamed H; Aggarwal, Sameer; Lim, Michael; Redmond, Kristin J; Rigamonti, Daniele; Kleinberg, Lawrence R

    2017-07-01

    There is no consensus regarding the optimal management of inoperable high-grade arteriovenous malformations (AVMs). This long-term study of 42 patients with high-grade AVMs reports obliteration and adverse event (AE) rates using planned multistage repeat stereotactic radiosurgery (SRS). To evaluate the efficacy and safety of multistage SRS with treatment of the entire AVM nidus at each treatment session to achieve complete obliteration of high-grade AVMs. Patients with high-grade Spetzler-Martin (S-M) III-V AVMs treated with at least 2 multistage SRS treatments from 1989 to 2013. Clinical outcomes of obliteration rate, minor/major AEs, and treatment characteristics were collected. Forty-two patients met inclusion criteria (n = 26, S-M III; n = 13, S-M IV; n = 3, S-M V) with a median follow-up was 9.5 yr after first SRS. Median number of SRS treatment stages was 2, and median interval between stages was 3.5 yr. Twenty-two patients underwent pre-SRS embolization. Complete AVM obliteration rate was 38%, and the median time to obliteration was 9.7 yr. On multivariate analysis, higher S-M grade was significantly associated ( P = .04) failure to achieve obliteration. Twenty-seven post-SRS AEs were observed, and the post-SRS intracranial hemorrhage rate was 0.027 events per patient year. Treatment of high-grade AVMs with multistage SRS achieves AVM obliteration in a meaningful proportion of patients with acceptable AE rates. Lower obliteration rates were associated with higher S-M grade and pre-SRS embolization. This approach should be considered with caution, as partial obliteration does not protect from hemorrhage. Copyright © 2017 by the Congress of Neurological Surgeons

  9. Factors Predictive of Symptomatic Radiation Injury After Linear Accelerator-Based Stereotactic Radiosurgery for Intracerebral Arteriovenous Malformations

    International Nuclear Information System (INIS)

    Herbert, Christopher; Moiseenko, Vitali; McKenzie, Michael; Redekop, Gary; Hsu, Fred; Gete, Ermias; Gill, Brad; Lee, Richard; Luchka, Kurt; Haw, Charles; Lee, Andrew; Toyota, Brian; Martin, Montgomery

    2012-01-01

    Purpose: To investigate predictive factors in the development of symptomatic radiation injury after treatment with linear accelerator–based stereotactic radiosurgery for intracerebral arteriovenous malformations and relate the findings to the conclusions drawn by Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC). Methods and Materials: Archived plans for 73 patients who were treated at the British Columbia Cancer Agency were studied. Actuarial estimates of freedom from radiation injury were calculated using the Kaplan-Meier method. Univariate and multivariate Cox proportional hazards models were used for analysis of incidence of radiation injury. Log–rank test was used to search for dosimetric parameters associated with freedom from radiation injury. Results: Symptomatic radiation injury was exhibited by 14 of 73 patients (19.2%). Actuarial rate of symptomatic radiation injury was 23.0% at 4 years. Most patients (78.5%) had mild to moderate deficits according to Common Terminology Criteria for Adverse Events, version 4.0. On univariate analysis, lesion volume and diameter, dose to isocenter, and a V x for doses ≥8 Gy showed statistical significance. Only lesion diameter showed statistical significance (p 5 cm 3 and diameters >30 mm were significantly associated with the risk of radiation injury (p 12 also showed strong association with the incidence of radiation injury. Actuarial incidence of radiation injury was 16.8% if V 12 was 3 and 53.2% if >28 cm 3 (log–rank test, p = 0.001). Conclusions: This study confirms that the risk of developing symptomatic radiation injury after radiosurgery is related to lesion diameter and volume and irradiated volume. Results suggest a higher tolerance than proposed by QUANTEC. The widely differing findings reported in the literature, however, raise considerable uncertainties.

  10. Factors Predictive of Symptomatic Radiation Injury After Linear Accelerator-Based Stereotactic Radiosurgery for Intracerebral Arteriovenous Malformations

    Energy Technology Data Exchange (ETDEWEB)

    Herbert, Christopher, E-mail: cherbert@bccancer.bc.ca [Department of Radiation Oncology, British Columbia Cancer Agency, Vancouver, BC (Canada); Moiseenko, Vitali [Department of Medical Physics, British Columbia Cancer Agency, Vancouver, BC (Canada); McKenzie, Michael [Department of Radiation Oncology, British Columbia Cancer Agency, Vancouver, BC (Canada); Redekop, Gary [Division of Neurosurgery, Vancouver General Hospital, University of British Columbia, Vancouver, BC (Canada); Hsu, Fred [Department of Radiation Oncology, British Columbia Cancer Agency, Abbotsford, BC (Canada); Gete, Ermias; Gill, Brad; Lee, Richard; Luchka, Kurt [Department of Medical Physics, British Columbia Cancer Agency, Vancouver, BC (Canada); Haw, Charles [Division of Neurosurgery, Vancouver General Hospital, University of British Columbia, Vancouver, BC (Canada); Lee, Andrew [Department of Neurosurgery, Royal Columbian Hospital, New Westminster, BC (Canada); Toyota, Brian [Division of Neurosurgery, Vancouver General Hospital, University of British Columbia, Vancouver, BC (Canada); Martin, Montgomery [Department of Medical Imaging, British Columbia Cancer Agency, Vancouver, BC (Canada)

    2012-07-01

    Purpose: To investigate predictive factors in the development of symptomatic radiation injury after treatment with linear accelerator-based stereotactic radiosurgery for intracerebral arteriovenous malformations and relate the findings to the conclusions drawn by Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC). Methods and Materials: Archived plans for 73 patients who were treated at the British Columbia Cancer Agency were studied. Actuarial estimates of freedom from radiation injury were calculated using the Kaplan-Meier method. Univariate and multivariate Cox proportional hazards models were used for analysis of incidence of radiation injury. Log-rank test was used to search for dosimetric parameters associated with freedom from radiation injury. Results: Symptomatic radiation injury was exhibited by 14 of 73 patients (19.2%). Actuarial rate of symptomatic radiation injury was 23.0% at 4 years. Most patients (78.5%) had mild to moderate deficits according to Common Terminology Criteria for Adverse Events, version 4.0. On univariate analysis, lesion volume and diameter, dose to isocenter, and a V{sub x} for doses {>=}8 Gy showed statistical significance. Only lesion diameter showed statistical significance (p < 0.05) in a multivariate model. According to the log-rank test, AVM volumes >5 cm{sup 3} and diameters >30 mm were significantly associated with the risk of radiation injury (p < 0.01). The V{sub 12} also showed strong association with the incidence of radiation injury. Actuarial incidence of radiation injury was 16.8% if V{sub 12} was <28 cm{sup 3} and 53.2% if >28 cm{sup 3} (log-rank test, p = 0.001). Conclusions: This study confirms that the risk of developing symptomatic radiation injury after radiosurgery is related to lesion diameter and volume and irradiated volume. Results suggest a higher tolerance than proposed by QUANTEC. The widely differing findings reported in the literature, however, raise considerable uncertainties.

  11. Predictors of Distant Brain Recurrence for Patients With Newly Diagnosed Brain Metastases Treated With Stereotactic Radiosurgery Alone

    International Nuclear Information System (INIS)

    Sawrie, Stephen M.; Guthrie, Barton L.; Spencer, Sharon A.; Nordal, Robert A.; Meredith, Ruby F.; Markert, James M.; Cloud, Gretchen A.; Fiveash, John B.

    2008-01-01

    Purpose: To ascertain predictors of distant brain failure (DBF) in patients treated initially with stereotactic radiosurgery alone for newly diagnosed brain metastases. We hypothesize that these factors may be used to group patients according to risk of DBF. Methods and Materials: We retrospectively analyzed 100 patients with newly diagnosed brain metastases treated from 2003 to 2005 at our Gamma Knife radiosurgery facility. The primary endpoint was DBF. Potential predictors included number of metastases, tumor volume, histologic characteristics, extracranial disease, and use of temozolomide. Results: One-year actuarial risk of DBF was 61% for all patients. Significant predictors of DBF included more than three metastases (hazard ratio, 3.30; p = 0.004), stable or poorly controlled extracranial disease (hazard ratio, 2.16; p = 0.04), and melanoma histologic characteristics (hazard ratio, 2.14; p = 0.02). These were confirmed in multivariate analysis. Those with three or fewer metastases, no extracranial disease, and nonmelanoma histologic characteristics (N = 18) had a median time to DBF of 89 weeks vs. 33 weeks for all others. One-year actuarial freedom from DBF for this group was 83% vs. 26% for all others. Conclusions: Independent significant predictors of DBF in our series included number of metastases (more than three), present or uncontrolled extracranial disease, and melanoma histologic characteristics. These factors were combined to identify a lower risk subgroup with significantly longer time to DBF. These patients may be candidates for initial localized treatment, reserving whole-brain radiation therapy for salvage. Patients in the higher risk group may be candidates for initial whole-brain radiation therapy or should be considered for clinical trials

  12. Linear accelerator radiosurgery for arteriovenous malformations: Updated literature review.

    Science.gov (United States)

    Yahya, S; Heyes, G; Nightingale, P; Lamin, S; Chavda, S; Geh, I; Spooner, D; Cruickshank, G; Sanghera, P

    2017-04-01

    Arteriovenous malformations (AVMs) are the leading causing of intra-cerebral haemorrhage. Stereotactic radiosurgery (SRS) is an established treatment for arteriovenous malformations (AVM) and commonly delivered using Gamma Knife within dedicated radiosurgery units. Linear accelerator (LINAC) SRS is increasingly available however debate remains over whether it offers an equivalent outcome. The aim of this project is to evaluate the outcomes using LINAC SRS for AVMs used within a UK neurosciences unit and review the literature to aid decision making across various SRS platforms. Results have shown comparability across platforms and strongly supports that an adapted LINAC based SRS facility within a dynamic regional neuro-oncology department delivers similar outcomes (in terms of obliteration and toxicity) to any other dedicated radio-surgical platform. Locally available facilities can facilitate discussion between options however throughput will inevitably be lower than centrally based dedicated national radiosurgery units. Copyright © 2016. Published by Elsevier Ltd.

  13. Diagnosis and treatment of brain metastasis

    International Nuclear Information System (INIS)

    Sajama, Carlos; Lorenzoni, Jose; Tagle, Patricio

    2008-01-01

    Cerebral metastasis occur in 20 to 30 percent of patients with systemic cancer and are the most common type of intracranial tumor. The median survival of untreated patients is one month with a slightly longer survival in those treated with steroids. Patients treated with whole brain radiation therapy survive between 3 to 6 months. In selected cases survival can increase to 10 to 12 months with combination of surgery and radiotherapy or stereotactic radiosurgery alone or associated to radiotherapy. Most brain metastasis arise from lung, breast and melanomas. The most important criteria for selecting patients who will benefit from surgery or stereotactic radiosurgery are a Karnofsky score of 70 or more, systemic control of the cancer and absence of leptomeningeal involvement. Surgery is indicated in patients with a single lesion located in an accessible zone and stereotactic radiosurgery is indicated for lesions up to 3 cm of diameter, and in patients with up to 3 or 4 metastasis, no matter their location. The survival benefit of chemotherapy in brain metastasis has not been demonstrated

  14. Technical Note: Using k-means clustering to determine the number and position of isocenters in MLC-based multiple target intracranial radiosurgery.

    Science.gov (United States)

    Yock, Adam D; Kim, Gwe-Ya

    2017-09-01

    To present the k-means clustering algorithm as a tool to address treatment planning considerations characteristic of stereotactic radiosurgery using a single isocenter for multiple targets. For 30 patients treated with stereotactic radiosurgery for multiple brain metastases, the geometric centroids and radii of each met were determined from the treatment planning system. In-house software used this as well as weighted and unweighted versions of the k-means clustering algorithm to group the targets to be treated with a single isocenter, and to position each isocenter. The algorithm results were evaluated using within-cluster sum of squares as well as a minimum target coverage metric that considered the effect of target size. Both versions of the algorithm were applied to an example patient to demonstrate the prospective determination of the appropriate number and location of isocenters. Both weighted and unweighted versions of the k-means algorithm were applied successfully to determine the number and position of isocenters. Comparing the two, both the within-cluster sum of squares metric and the minimum target coverage metric resulting from the unweighted version were less than those from the weighted version. The average magnitudes of the differences were small (-0.2 cm 2 and 0.1% for the within cluster sum of squares and minimum target coverage, respectively) but statistically significant (Wilcoxon signed-rank test, P k-means clustering algorithm represented an advantage of the unweighted version for the within-cluster sum of squares metric, and an advantage of the weighted version for the minimum target coverage metric. While additional treatment planning considerations have a large influence on the final treatment plan quality, both versions of the k-means algorithm provide automatic, consistent, quantitative, and objective solutions to the tasks associated with SRS treatment planning using a single isocenter for multiple targets. © 2017 The Authors. Journal

  15. A comparison of arc-based and static mini-multileaf collimator-based radiosurgery treatment plans

    International Nuclear Information System (INIS)

    Kubo, Hideo Dale; Pappas, Conrad T.E.; Wilder, Richard B.

    1997-01-01

    Background: The purpose of this study is to compare arc-based and mini-multileaf collimator (mMLC)-based radiosurgery treatment plans using isodose distributions and dose-volume histograms. Methods: Of 11 patients who underwent conventional arc-based radiosurgery for intracranial malignancies, four were treated with one isocenter, four were treated with two isocenters and three were treated with three isocenters. The same cases were re-planned using a test version of mMLC-based radiosurgery software for multiple static non-coplanar fields. Results and conclusion: For non-spherical targets, treatment planning is relatively intuitive with mMLC-based radiosurgery, reducing the amount of time required for planning. Moreover, a lower dose of radiation is delivered to normal tissue with mMLC-based radiosurgery than with arc-based radiosurgery, which theoretically should lead to a reduced risk of complications

  16. Stereotactic Fractionated Radiotherapy and LINAC Radiosurgery in the Treatment of Vestibular Schwannoma-Report About Both Stereotactic Methods From a Single Institution

    International Nuclear Information System (INIS)

    Kopp, Christine; Fauser, Claudius; Mueller, Axel; Astner, Sabrina T.; Jacob, Vesna; Lumenta, Christianto; Meyer, Bernhard; Tonn, Joerg-Christian; Molls, Michael; Grosu, Anca-Ligia

    2011-01-01

    Purpose: To evaluate tumor control and side effects associated with radiosurgery (RS) and stereotactic fractionated radiotherapy (SFR) for vestibular schwannomas (VSs) in a group of patients treated at the same institution. Methods and Materials: Between May 1997 and June 2007, 115 consecutive cases of VS were treated in our department. The SFR group (47 patients), including larger tumors (maximum diameter >1.5 cm), received a total dose of 54 Gy at 1.8 Gy per fraction. The RS group (68 patients, maximum diameter <1.5 cm) received a total dose of 12 Gy at the 100% isodose. Evaluation included serial imaging tests (magnetic resonance imaging) and neurologic and functional hearing examinations. Results: The tumor control rate was 97.9% in the SFR group for a mean follow-up time of 32.1 months and 98.5% in the RS group for a mean follow-up time of 30.1 months. Hearing function was preserved after RS in 85% of the patients and after SFR in 79%. Facial and trigeminal nerve function remained mostly unaffected after SFR. After RS, new trigeminal neuropathy occurred in 9 of 68 patients (13%). Conclusions: A high tumor control rate and low number of side effects are registered after SFR and RS of VS. These results confirm that considering tumor diameter, both RS and SFR are good treatment modalities for VS.

  17. Stereotactic Radiotherapy by 6MV Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Oho, Yoon Kyeong; Kim, Mi Hee; Gil, Hak Jun [Catholic University College of Medicine, Seoul (Korea, Republic of)] (and others)

    1988-12-15

    Eight patients with intracranial tumors or arteriovenous malformation (AVM)s which were less than 3 cm in diameter were treated by a technique of stereotactic radiotherapy during the 4 months period from July 1988 through October 1988 at the Division of Radiation Therapy, Kang-Nam St. Mary's Hospital, Catholic University Medical College. The patients were diagnosed as AVMs in 3 cases, acoustic neurinoma, craniopharyngioma (recurrent), hemangioblastoma, pineocytoma, and pituitary microadenoma in each case. There are several important factors in this procedure, such as localization system, portal, field size, radiation dose, and perioperative supportive care. It is suggested that stereotactic radiotherapy may be performed safely with a radiation dose of 12-30 Gy. So this noninvasive procedure can be used to treat unresectable intracranial tumors or AVMs. Of these, clinical symptoms had been regressed in AVMs in 2 cases at 3 months and 2 months after Stereotactic radiotherapy, one of whom was confirmed slightly regressed on the follow-up angiogram. And also craniopharyngioma and pineocytoma was minimally regressed on 3 month follow-up CT.

  18. Stereotactic Radiotherapy by 6MV Linear Accelerator

    International Nuclear Information System (INIS)

    Oho, Yoon Kyeong; Kim, Mi Hee; Gil, Hak Jun

    1988-01-01

    Eight patients with intracranial tumors or arteriovenous malformation (AVM)s which were less than 3 cm in diameter were treated by a technique of stereotactic radiotherapy during the 4 months period from July 1988 through October 1988 at the Division of Radiation Therapy, Kang-Nam St. Mary's Hospital, Catholic University Medical College. The patients were diagnosed as AVMs in 3 cases, acoustic neurinoma, craniopharyngioma (recurrent), hemangioblastoma, pineocytoma, and pituitary microadenoma in each case. There are several important factors in this procedure, such as localization system, portal, field size, radiation dose, and perioperative supportive care. It is suggested that stereotactic radiotherapy may be performed safely with a radiation dose of 12-30 Gy. So this noninvasive procedure can be used to treat unresectable intracranial tumors or AVMs. Of these, clinical symptoms had been regressed in AVMs in 2 cases at 3 months and 2 months after Stereotactic radiotherapy, one of whom was confirmed slightly regressed on the follow-up angiogram. And also craniopharyngioma and pineocytoma was minimally regressed on 3 month follow-up CT

  19. Stereotactic radiosurgery for brain metastases

    International Nuclear Information System (INIS)

    Obedian, E.; Lotbiniere, A.C.J. de; Haffty, B.G.; Piepmeier, J.M.; Fischer, D.B.; Knisely, J.P.S.

    1997-01-01

    Purpose: This study evaluates the influence of several prognostic factors on overall survival and progression free survival in patients undergoing stereotactic radiosurgery (SRS) for brain metastases. Materials and Methods: Records of 61 coecutive patients with pathologically confirmed extra-cranial malignancies undergoing SRS at Yale University School of Medicine between 12/18/91 and 7/2/96 were reviewed. All patients underwent head frame localization and CT and/or MRI based treatment planning. Outcome was analyzed with respect to age, number of lesions, size of lesions, location of lesions, site and stage of primary tumor, status of primary tumor at time of SRS, history of whole brain radiation therapy (WBRT), surgery, and/or chemotherapy prior to or after SRS, delay in SRS from diagnosis of brain metastases, dose of radiation delivered, and brain metastasis free interval. Both overall survival and progression free survival were analyzed by the Kaplan-Meier method. Tests for statistical significance were performed using the Cox proportional hazards model. Results: Median follow-up was 29 months. 3% ((8(61))) of patients displayed evidence of progressive disease at the site of SRS, and 87% ((53(61))) of patients have died. Overall and progression free survival rates for the entire cohort of patients were 43.8% and 89.5% at 1 year and 11.1% and 71.4% at 2 years, respectively. Patients undergoing SRS for a solitary brain metastasis had a significant improvement in overall survival with 1 year survival rates of 52.6% vs. 32.7% for patients undergoing SRS for more than 1 brain metastasis (p=0.002). Patients who presented with progressive systemic disease at the time of SRS had an inferior overall survival with a 1 year survival rate of 15.4% compared to patients with presumed/known stable disease who had a 1 year survival rate of 51.5%/54.2% (p<0.001). Patients treated for cerebral metastases had a higher progression free survival compared to patients undergoing SRS

  20. Development of a frameless stereotactic radiosurgery system based on real-time 6D position monitoring and adaptive head motion compensation

    Energy Technology Data Exchange (ETDEWEB)

    Wiersma, Rodney D; Wen Zhifei; Sadinski, Meredith; Farrey, Karl; Yenice, Kamil M [Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL 60637 (United States)], E-mail: rwiersma@uchicago.edu

    2010-01-21

    Stereotactic radiosurgery delivers radiation with great spatial accuracy. To achieve sub-millimeter accuracy for intracranial SRS, a head ring is rigidly fixated to the skull to create a fixed reference. For some patients, the invasiveness of the ring can be highly uncomfortable and not well tolerated. In addition, placing and removing the ring requires special expertise from a neurosurgeon, and patient setup time for SRS can often be long. To reduce the invasiveness, hardware limitations and setup time, we are developing a system for performing accurate head positioning without the use of a head ring. The proposed method uses real-time 6D optical position feedback for turning on and off the treatment beam (gating) and guiding a motor-controlled 3D head motion compensation stage. The setup consists of a central control computer, an optical patient motion tracking system and a 3D motion compensation stage attached to the front of the LINAC couch. A styrofoam head cast was custom-built for patient support and was mounted on the compensation stage. The motion feedback of the markers was processed by the control computer, and the resulting motion of the target was calculated using a rigid body model. If the target deviated beyond a preset position of 0.2 mm, an automatic position correction was performed with stepper motors to adjust the head position via the couch mount motion platform. In the event the target deviated more than 1 mm, a safety relay switch was activated and the treatment beam was turned off. The feasibility of the concept was tested using five healthy volunteers. Head motion data were acquired with and without the use of motion compensation over treatment times of 15 min. On average, test subjects exceeded the 0.5 mm tolerance 86% of the time and the 1.0 mm tolerance 45% of the time without motion correction. With correction, this percentage was reduced to 5% and 2% for the 0.5 mm and 1.0 mm tolerances, respectively.

  1. Development of a frameless stereotactic radiosurgery system based on real-time 6D position monitoring and adaptive head motion compensation

    International Nuclear Information System (INIS)

    Wiersma, Rodney D; Wen Zhifei; Sadinski, Meredith; Farrey, Karl; Yenice, Kamil M

    2010-01-01

    Stereotactic radiosurgery delivers radiation with great spatial accuracy. To achieve sub-millimeter accuracy for intracranial SRS, a head ring is rigidly fixated to the skull to create a fixed reference. For some patients, the invasiveness of the ring can be highly uncomfortable and not well tolerated. In addition, placing and removing the ring requires special expertise from a neurosurgeon, and patient setup time for SRS can often be long. To reduce the invasiveness, hardware limitations and setup time, we are developing a system for performing accurate head positioning without the use of a head ring. The proposed method uses real-time 6D optical position feedback for turning on and off the treatment beam (gating) and guiding a motor-controlled 3D head motion compensation stage. The setup consists of a central control computer, an optical patient motion tracking system and a 3D motion compensation stage attached to the front of the LINAC couch. A styrofoam head cast was custom-built for patient support and was mounted on the compensation stage. The motion feedback of the markers was processed by the control computer, and the resulting motion of the target was calculated using a rigid body model. If the target deviated beyond a preset position of 0.2 mm, an automatic position correction was performed with stepper motors to adjust the head position via the couch mount motion platform. In the event the target deviated more than 1 mm, a safety relay switch was activated and the treatment beam was turned off. The feasibility of the concept was tested using five healthy volunteers. Head motion data were acquired with and without the use of motion compensation over treatment times of 15 min. On average, test subjects exceeded the 0.5 mm tolerance 86% of the time and the 1.0 mm tolerance 45% of the time without motion correction. With correction, this percentage was reduced to 5% and 2% for the 0.5 mm and 1.0 mm tolerances, respectively.

  2. The university of Florida frameless high-precision stereotactic radiotherapy system

    International Nuclear Information System (INIS)

    Bova, Francis J.; Buatti, John M.; Friedman, William A.; Mendenhall, William M.; Yang, Ching-Chong; Liu, Chihray

    1997-01-01

    Purpose: To develop and test a system for high precision fractionated stereotactic radiotherapy that separates immobilization and localization devices. Methods and Materials: Patient localization is achieved through detection and digital registration of an independent bite plate system. The bite plate is made and linked to a set of six infrared light emitting diodes (IRLEDs). These IRLEDs are detected by an infrared camera system that identifies the position of each IRLED within 0.1 to 0.15 mm. Calibration of the camera system defines isocenter and translational X, Y, and Z axes of the stereotactic radiosurgery subsystem and thereby digitally defines the virtual treatment room space in a computer linked to the camera system. Positions of the bite plate's IRLEDs are processed digitally using a computer algorithm so that positional differences between an actual bite plate position and a desired position can be resolved within 0.1 mm of translation (X, Y, and Z distance) and 0.1 degree of rotation. Furthermore, bite plate misalignment can be displayed digitally in real time with translational (x, y, and z) and rotational (roll, pitch, and yaw) parameters for an actual bite plate position. Immobilization is achieved by a custom head mold and thermal plastic mask linked by hook-and-loop fastener tape. The head holder system permits rotational and translational movements for daily treatment positioning based on the bite plate localization system. Initial testing of the localization system was performed on 20 patients treated with radiosurgery. The system was used to treat 11 patients with fractionated stereotactic radiotherapy. Results: Assessment of bite plate localization in radiosurgery patients revealed that the patient's bite plate could be positioned and repositioned within 0.5 ± 0.3 mm (standard deviation). After adjustments, the first 11 patients were treated with the bite plate repositioning error reduced to 0.2 ± 0.1 mm. Conclusions: High precision

  3. Determination of gonad doses during robotic stereotactic radiosurgery for various tumor sites

    International Nuclear Information System (INIS)

    Zorlu, Faruk; Dugel, Gozde; Ozyigit, Gokhan; Hurmuz, Pervin; Cengiz, Mustafa; Yildiz, Ferah; Akyol, Fadil; Gurkaynak, Murat

    2013-01-01

    Purpose: The authors evaluated the absorbed dose received by the gonads during robotic stereotactic radiosurgery (SRS) for the treatment of different tumor localizations. Methods: The authors measured the gonad doses during the treatment of head and neck, thoracic, abdominal, or pelvic tumors in both RANDO phantom and actual patients. The computerized tomography images were transferred to the treatment planning system. The contours of tumor and critical organs were delineated on each slice, and treatment plans were generated. Measurements for gonad doses were taken from the geometric projection of the ovary onto the skin for female patients, and from the scrotal skin for male patients by attaching films and Thermoluminescent dosimeters (TLDs). SRS was delivered with CyberKnife (Accuray Inc., Sunnyvale, CA). Results: The median gonadal doses with TLD and film dosimeter in actual patients were 0.19 Gy (range, 0.035–2.71 Gy) and 0.34 Gy (range, 0.066–3.18 Gy), respectively. In the RANDO phantom, the median ovarian doses with TLD and film dosimeter were 0.08 Gy (range, 0.03–0.159 Gy) and 0.05 Gy (range, 0.015–0.13 Gy), respectively. In the RANDO phantom, the median testicular doses with TLD and film dosimeter were 0.134 Gy (range 0.056–1.97 Gy) and 0.306 Gy (range, 0.065–2.25 Gy). Conclusions: Gonad doses are below sterility threshold in robotic SRS for different tumor localizations. However, particular attention should be given to gonads during robotic SRS for pelvic tumors.

  4. Determination of gonad doses during robotic stereotactic radiosurgery for various tumor sites

    Energy Technology Data Exchange (ETDEWEB)

    Zorlu, Faruk; Dugel, Gozde; Ozyigit, Gokhan; Hurmuz, Pervin; Cengiz, Mustafa; Yildiz, Ferah; Akyol, Fadil; Gurkaynak, Murat [Hacettepe University Faculty of Medicine, Department of Radiation Oncology, Ankara 06100 (Turkey)

    2013-04-15

    Purpose: The authors evaluated the absorbed dose received by the gonads during robotic stereotactic radiosurgery (SRS) for the treatment of different tumor localizations. Methods: The authors measured the gonad doses during the treatment of head and neck, thoracic, abdominal, or pelvic tumors in both RANDO phantom and actual patients. The computerized tomography images were transferred to the treatment planning system. The contours of tumor and critical organs were delineated on each slice, and treatment plans were generated. Measurements for gonad doses were taken from the geometric projection of the ovary onto the skin for female patients, and from the scrotal skin for male patients by attaching films and Thermoluminescent dosimeters (TLDs). SRS was delivered with CyberKnife (Accuray Inc., Sunnyvale, CA). Results: The median gonadal doses with TLD and film dosimeter in actual patients were 0.19 Gy (range, 0.035-2.71 Gy) and 0.34 Gy (range, 0.066-3.18 Gy), respectively. In the RANDO phantom, the median ovarian doses with TLD and film dosimeter were 0.08 Gy (range, 0.03-0.159 Gy) and 0.05 Gy (range, 0.015-0.13 Gy), respectively. In the RANDO phantom, the median testicular doses with TLD and film dosimeter were 0.134 Gy (range 0.056-1.97 Gy) and 0.306 Gy (range, 0.065-2.25 Gy). Conclusions: Gonad doses are below sterility threshold in robotic SRS for different tumor localizations. However, particular attention should be given to gonads during robotic SRS for pelvic tumors.

  5. Analysis of metabolic change by Tl-201 SPECT in brain tumors treated with stereotactic radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Sugo, Nobuo [Toho Univ., Tokyo (Japan). School of Medicine

    1996-03-01

    The time course for changes in Tl-201 uptake and tumor size was studied correlatively. A total of 24 cases of brain tumors was enrolled in the study. Three detector type scanner, PRISM 3000 was used. SPECT scanning was started 10 min after intravenous administration of 111 MBq of Tl-201, and sequentially repeated every 1 min for 16 min. Tl-201 radioactivity was counted in two regions of interest (ROI). One was an area encircling the tumor, and the other, an area in the contralateral hemisphere that served as control. Tl index (TI) was calculated by this formula: TI=T-C/C, where T is the count in the tumor and C, the count in the control area. The size of a given tumor was represented by its maximum diameter as determined by CT or MRI. The TI and the tumor size were compared before and after radiosurgery. In all cases, a decrease in TI was seen earlier than a reduction in tumor size. Among malignant tumors, the TI decrease took place as early as one week, and rapidly reached the lowest level. On the other hand, in benign tumors, it took as long as 6 to 12 months for the decrease of the TI to be evident; the subsequent was very slow. The difference between malignant and benign tumors of the brain is attributed to the fact that high dose irradiation of the malignant, radiosensitive tumors causes deep disturbances in cell metabolism that lead to cell death. By contrast, irradiation of a benign tumor with low radiosensitivity does not affect the cellular metabolism, but injures the vascular wall, leading to gradual stenosis or obliteration of the vessels in the tumor. These data strongly suggest that the rapid and marked decrease of malignant tumors after stereotactic radiosurgery is the result of a direct injury to the malignant cells, and that the rather slow and insufficient diminution of benign tumors can be attributed to diminished blood supply to the tumor. (author)

  6. Anti-PD-1 Blockade and Stereotactic Radiation Produce Long-Term Survival in Mice With Intracranial Gliomas

    International Nuclear Information System (INIS)

    Zeng, Jing; See, Alfred P.; Phallen, Jillian; Jackson, Christopher M.; Belcaid, Zineb; Ruzevick, Jacob; Durham, Nicholas; Meyer, Christian; Harris, Timothy J.; Albesiano, Emilia; Pradilla, Gustavo; Ford, Eric; Wong, John; Hammers, Hans-Joerg; Mathios, Dimitris; Tyler, Betty; Brem, Henry; Tran, Phuoc T.; Pardoll, Drew; Drake, Charles G.

    2013-01-01

    Purpose: Glioblastoma multiforme (GBM) is the most common primary brain tumor in adults, and radiation is one of the main treatment modalities. However, cure rates remain low despite best available therapies. Immunotherapy is a promising modality that could work synergistically with radiation, which has been shown to increase antigen presentation and promote a proinflammatory tumor microenvironment. Programmed-death-1 (PD-1) is a surface receptor expressed on activated and exhausted T cells, which mediate T cell inhibition upon binding with its ligand PD-L1, expressed on many tumor types including human GBMs. We tested the combination of anti-PD-1 immunotherapy with stereotactic radiosurgery in a mouse orthotopic GBM model. Methods and Materials: We performed intracranial implantation of mouse glioma cell line GL261 transfected with luciferase into C57BL/6 mice. Mice were stratified into 4 treatment groups: (1) control; (2) radiation only; (3) anti-PD-1 antibody only; and (4) radiation plus anti-PD-1 antibody. Overall survival was quantified. The mice were killed on day 21 after implantation to assess immunologic parameters in the brain/tumor, cervical lymph nodes, and spleen. Results: Improved survival was demonstrated with combination anti-PD-1 therapy plus radiation compared with either modality alone: median survival was 25 days in the control arm, 27 days in the anti-PD-1 antibody arm, 28 days in the radiation arm, and 53 days in the radiation plus anti-PD-1 therapy arm (P<.05 by log-rank Mantle-Cox). Long-term survival was seen only in the combined treatment arm, with a fraction (15%-40%) of animals alive at day 180+ after treatment. Immunologic data on day 21 after implantation showed increased tumor infiltration by cytotoxic T cells (CD8+/interferon-γ+/tumor necrosis factor-α+) and decreased regulatory T cells (CD4+/FOXP3) in the combined treatment group compared with the single modality arms. Conclusions: The combination of PD-1 blockade and localized

  7. Anti-PD-1 Blockade and Stereotactic Radiation Produce Long-Term Survival in Mice With Intracranial Gliomas

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Jing [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medical Institutes, Baltimore, Maryland (United States); See, Alfred P.; Phallen, Jillian; Jackson, Christopher M.; Belcaid, Zineb; Ruzevick, Jacob [Department of Neurosurgery, Johns Hopkins Medical Institutes, Baltimore, Maryland (United States); Durham, Nicholas [Department of Immunology, Johns Hopkins Medical Institutes, Baltimore, Maryland (United States); Meyer, Christian [Department of Oncology, Johns Hopkins Medical Institutes, Baltimore, Maryland (United States); Harris, Timothy J. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medical Institutes, Baltimore, Maryland (United States); Albesiano, Emilia; Pradilla, Gustavo [Department of Neurosurgery, Johns Hopkins Medical Institutes, Baltimore, Maryland (United States); Ford, Eric; Wong, John [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medical Institutes, Baltimore, Maryland (United States); Hammers, Hans-Joerg [Department of Immunology, Johns Hopkins Medical Institutes, Baltimore, Maryland (United States); Mathios, Dimitris; Tyler, Betty; Brem, Henry [Department of Neurosurgery, Johns Hopkins Medical Institutes, Baltimore, Maryland (United States); Tran, Phuoc T. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medical Institutes, Baltimore, Maryland (United States); Pardoll, Drew; Drake, Charles G. [Department of Immunology, Johns Hopkins Medical Institutes, Baltimore, Maryland (United States); and others

    2013-06-01

    Purpose: Glioblastoma multiforme (GBM) is the most common primary brain tumor in adults, and radiation is one of the main treatment modalities. However, cure rates remain low despite best available therapies. Immunotherapy is a promising modality that could work synergistically with radiation, which has been shown to increase antigen presentation and promote a proinflammatory tumor microenvironment. Programmed-death-1 (PD-1) is a surface receptor expressed on activated and exhausted T cells, which mediate T cell inhibition upon binding with its ligand PD-L1, expressed on many tumor types including human GBMs. We tested the combination of anti-PD-1 immunotherapy with stereotactic radiosurgery in a mouse orthotopic GBM model. Methods and Materials: We performed intracranial implantation of mouse glioma cell line GL261 transfected with luciferase into C57BL/6 mice. Mice were stratified into 4 treatment groups: (1) control; (2) radiation only; (3) anti-PD-1 antibody only; and (4) radiation plus anti-PD-1 antibody. Overall survival was quantified. The mice were killed on day 21 after implantation to assess immunologic parameters in the brain/tumor, cervical lymph nodes, and spleen. Results: Improved survival was demonstrated with combination anti-PD-1 therapy plus radiation compared with either modality alone: median survival was 25 days in the control arm, 27 days in the anti-PD-1 antibody arm, 28 days in the radiation arm, and 53 days in the radiation plus anti-PD-1 therapy arm (P<.05 by log-rank Mantle-Cox). Long-term survival was seen only in the combined treatment arm, with a fraction (15%-40%) of animals alive at day 180+ after treatment. Immunologic data on day 21 after implantation showed increased tumor infiltration by cytotoxic T cells (CD8+/interferon-γ+/tumor necrosis factor-α+) and decreased regulatory T cells (CD4+/FOXP3) in the combined treatment group compared with the single modality arms. Conclusions: The combination of PD-1 blockade and localized

  8. Single-session Gamma Knife radiosurgery for optic pathway/hypothalamic gliomas.

    Science.gov (United States)

    El-Shehaby, Amr M N; Reda, Wael A; Abdel Karim, Khaled M; Emad Eldin, Reem M; Nabeel, Ahmed M

    2016-12-01

    OBJECTIVE Because of their critical and central location, it is deemed necessary to fractionate when considering irradiating optic pathway/hypothalamic gliomas. Stereotactic fractionated radiotherapy is considered safer when dealing with gliomas in this location. In this study, the safety and efficacy of single-session stereotactic radiosurgery for optic pathway/hypothalamic gliomas were reviewed. METHODS Between December 2004 and June 2014, 22 patients with optic pathway/hypothalamic gliomas were treated by single-session Gamma Knife radiosurgery. Twenty patients were available for follow-up for a minimum of 1 year after treatment. The patients were 5 to 43 years (median 16 years) of age. The tumor volume was 0.15 to 18.2 cm 3 (median 3.1 cm 3 ). The prescription dose ranged from 8 to 14 Gy (median 11.5 Gy). RESULTS The mean follow-up period was 43 months. Five tumors involved the optic nerve only, and 15 tumors involved the chiasm/hypothalamus. Two patients died during the follow-up period. The tumors shrank in 12 cases, remained stable in 6 cases, and progressed in 2 cases, thereby making the tumor control rate 90%. Vision remained stable in 12 cases, improved in 6 cases, and worsened in 2 cases in which there was tumor progression. Progression-free survival was 83% at 3 years. CONCLUSIONS The initial results indicate that single-session Gamma Knife radiosurgery is a safe and effective treatment option for optic pathway/hypothalamic gliomas.

  9. [Linear accelerator-based stereotactic radiosurgery for the treatment of trigeminal neuralgia. Nine years' experience in a single institution].

    Science.gov (United States)

    Serrano-Rubio, A A; Martinez-Manrique, J J; Revuelta-Gutierrez, R; Gomez-Amador, J L; Martinez-Anda, J J; Ponce-Gomez, J A; Moreno-Jimenez, S

    2014-09-16

    INTRODUCTION. Pharmacological treatment is the first therapeutic step towards controlling pain in trigeminal neuralgia, but 25-50% of patients become medication resistant. There are currently several surgical alternatives for treating these patients. AIM. To evaluate the effectiveness and safety of stereotactic radiosurgery for the treatment of patients with trigeminal neuralgia. PATIENTS AND METHODS. A follow-up study was conducted on 30 patients who underwent radiosurgery using a Novalis linear accelerator. Eighty per cent of the dosage was calculated at the isocentre, the entry zone of the root of the trigeminal nerve. The mean follow-up time was 27.5 months (range: 1-65 months). RESULTS. The mean age was 66 years (range: 36-87 years), with a time to progression of 7.1 years (range: 4-27 years). The distribution of the pain was from the right side (63.3%). Of the 30 patients, 27 experienced an improvement (90%) 1.6 months (range: 1 week-4 months) after the treatment; 10 patients (33.3%) scored grade I, and 17 patients (56.6%) obtained a score of grade II. During the follow-up, four patients (14.2%) suffered a relapse; two underwent re-irradiation. Time without recurrence was 62.7 months (range: 54.6-70.8 months). The rate of side effects was 76.7% and only three patients developed facial anaesthesia with loss of the corneal reflex. CONCLUSIONS. The use of the linear accelerator is an effective therapeutic option in the treatment of trigeminal neuralgia, since it provides adequate long-term control of the pain, reduces the use of medication and improves the quality of life.

  10. TH-A-BRC-01: AAPM TG-135U1 QA for Robotic Radiosurgery

    International Nuclear Information System (INIS)

    Dieterich, S.

    2016-01-01

    AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline

  11. TH-A-BRC-01: AAPM TG-135U1 QA for Robotic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Dieterich, S. [UC Davis Medical Center (United States)

    2016-06-15

    AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline

  12. Intra-arterial angio-CT for radiosurgery of cerebral arteriovenous malformations

    International Nuclear Information System (INIS)

    Tanami, Yutaka; Kunieda, Etsuo; Onozuka, Satoshi

    1998-01-01

    Intra-arterial CT-angiograms were performed for four patients undergoing stereotactic radiosurgery for cerebral arteriovenous malformations (AVM). Helical and dynamic CT scans were carried out with a scanner installed in a angiographic examination room following routine angiography. Helical scans were performed with continuous arterial infusion of contrast media. Then, dynamic scans were repeated at several table positions. Subtractions were achieved for a post-embolization case. Normal and pathological vascular structures were demonstrated with different enhancement phases with the dynamic scans. The coordinates of the target points in the nidus could be clearly determined. We concluded that intra-arterial CT-angiograms are practical and useful for treatment planning of radiosurgery for cerebral AVM. (author)

  13. Intra-arterial angio-CT for radiosurgery of cerebral arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Tanami, Yutaka; Kunieda, Etsuo; Onozuka, Satoshi [Keio Univ., Tokyo (Japan) School of Medicine] [and others

    1998-08-01

    Intra-arterial CT-angiograms were performed for four patients undergoing stereotactic radiosurgery for cerebral arteriovenous malformations (AVM). Helical and dynamic CT scans were carried out with a scanner installed in a angiographic examination room following routine angiography. Helical scans were performed with continuous arterial infusion of contrast media. Then, dynamic scans were repeated at several table positions. Subtractions were achieved for a post-embolization case. Normal and pathological vascular structures were demonstrated with different enhancement phases with the dynamic scans. The coordinates of the target points in the nidus could be clearly determined. We concluded that intra-arterial CT-angiograms are practical and useful for treatment planning of radiosurgery for cerebral AVM. (author)

  14. Stereotactic radiosurgery XX: ocular neuromyotonia in association with gamma knife radiosurgery

    Science.gov (United States)

    McQuillan, Joe; Plowman, P Nicholas; MacDougall, Niall; Blackburn, Philip; Sabin, H Ian; Ali, Nadeem; Drake, William M

    2015-01-01

    Summary We report three patients who developed symptoms and signs of ocular neuromyotonia (ONM) 3–6 months after receiving gamma knife radiosurgery (GKS) for functioning pituitary tumours. All three patients were complex, requiring multi-modality therapy and all had received prior external irradiation to the sellar region. Although direct causality cannot be attributed, the timing of the development of the symptoms would suggest that the GKS played a contributory role in the development of this rare problem, which we suggest clinicians should be aware of as a potential complication. Learning points GKS can cause ONM, presenting as intermittent diplopia.ONM can occur quite rapidly after treatment with GKS.Treatment with carbamazepine is effective and improve patient's quality of life. PMID:26294961

  15. Verification of gamma knife based fractionated radiosurgery with newly developed head-thorax phantom

    International Nuclear Information System (INIS)

    Bisht, Raj Kishor; Kale, Shashank Sharad; Natanasabapathi, Gopishankar; Singh, Manmohan Jit; Agarwal, Deepak; Garg, Ajay; Rath, Goura Kishore; Julka, Pramod Kumar; Kumar, Pratik; Thulkar, Sanjay; Sharma, Bhawani Shankar

    2016-01-01

    Objective: Purpose of the study is to verify the Gamma Knife Extend™ system (ES) based fractionated stereotactic radiosurgery with newly developed head-thorax phantom. Methods: Phantoms are extensively used to measure radiation dose and verify treatment plan in radiotherapy. A human upper body shaped phantom with thorax was designed to simulate fractionated stereotactic radiosurgery using Extend™ system of Gamma Knife. The central component of the phantom aids in performing radiological precision test, dosimetric evaluation and treatment verification. A hollow right circular cylindrical space of diameter 7.0 cm was created at the centre of this component to place various dosimetric devices using suitable adaptors. The phantom is made of poly methyl methacrylate (PMMA), a transparent thermoplastic material. Two sets of disk assemblies were designed to place dosimetric films in (1) horizontal (xy) and (2) vertical (xz) planes. Specific cylindrical adaptors were designed to place thimble ionization chamber inside phantom for point dose recording along xz axis. EBT3 Gafchromic films were used to analyze and map radiation field. The focal precision test was performed using 4 mm collimator shot in phantom to check radiological accuracy of treatment. The phantom head position within the Extend™ frame was estimated using encoded aperture measurement of repositioning check tool (RCT). For treatment verification, the phantom with inserts for film and ion chamber was scanned in reference treatment position using X-ray computed tomography (CT) machine and acquired stereotactic images were transferred into Leksell Gammaplan (LGP). A patient treatment plan with hypo-fractionated regimen was delivered and identical fractions were compared using EBT3 films and in-house MATLAB codes. Results: RCT measurement showed an overall positional accuracy of 0.265 mm (range 0.223 mm–0.343 mm). Gamma index analysis across fractions exhibited close agreement between LGP and film

  16. Esophageal Toxicity From High-Dose, Single-Fraction Paraspinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Cox, Brett W.; Jackson, Andrew; Hunt, Margie; Bilsky, Mark; Yamada, Yoshiya

    2012-01-01

    Purpose: To report the esophageal toxicity from single-fraction paraspinal stereotactic radiosurgery (SRS) and identify dosimetric and clinical risk factors for toxicity. Methods and Materials: A total of 204 spinal metastases abutting the esophagus (182 patients) were treated with high-dose single-fraction SRS during 2003-2010. Toxicity was scored using the National Cancer Institute Common Toxicity Criteria for Adverse Events, version 4.0. Dose-volume histograms were combined to generate a comprehensive atlas of complication incidence that identifies risk factors for toxicity. Correlation of dose-volume factors with esophageal toxicity was assessed using Fisher’s exact test and logistic regression. Clinical factors were correlated with toxicity. Results: The median dose to the planning treatment volume was 24 Gy. Median follow-up was 12 months (range, 3-81). There were 31 (15%) acute and 24 (12%) late esophageal toxicities. The rate of grade ≥3 acute or late toxicity was 6.8% (14 patients). Fisher’s exact test resulted in significant median splits for grade ≥3 toxicity at V12 = 3.78 cm 3 (relative risk [RR] 3.7, P=.05), V15 = 1.87 cm 3 (RR 13, P=.0013), V20 = 0.11 cm 3 (RR 6, P=0.01), and V22 = 0.0 cm 3 (RR 13, P=.0013). The median split for D2.5 cm 3 (14.02 Gy) was also a significant predictor of toxicity (RR 6; P=.01). A highly significant logistic regression model was generated on the basis of D2.5 cm 3 . One hundred percent (n = 7) of grade ≥4 toxicities were associated with radiation recall reactions after doxorubicin or gemcitabine chemotherapy or iatrogenic manipulation of the irradiated esophagus. Conclusions: High-dose, single-fraction paraspinal SRS has a low rate of grade ≥3 esophageal toxicity. Severe esophageal toxicity is minimized with careful attention to esophageal doses during treatment planning. Iatrogenic manipulation of the irradiated esophagus and systemic agents classically associated with radiation recall reactions are

  17. Outcome After Radiosurgery for Brain Metastases in Patients With Low Karnofsky Performance Scale (KPS) Scores

    International Nuclear Information System (INIS)

    Chernov, Mikhail F.; Nakaya, Kotaro; Izawa, Masahiro; Hayashi, Motohiro; Usuba, Yuki; Kato, Koichi; Muragaki, Yoshihiro; Iseki, Hiroshi; Hori, Tomokatsu; Takakura, Kintomo

    2007-01-01

    Purpose: The objective of this retrospective study was evaluation of the outcome after stereotactic radiosurgery (SRS) in patients with intracranial metastases and poor performance status. Methods and Materials: Forty consecutive patients with metastatic brain tumors and Karnofsky performance scale (KPS) scores ≤50 (mean, 43 ± 8; median, 40) treated with SRS were analyzed. Poor performance status was caused by presence of intracranial metastases in 28 cases (70%) and resulted from uncontrolled extracerebral disease in 12 (30%). Results: Survival after SRS varied from 3 days to 11.5 months (mean, 3.8 ± 2.9 months; median, 3.3 months). Survival probability constituted 0.50 ± 0.07 at 3 months and 0.20 ± 0.05 at 6 months posttreatment. Cause of low KPS score (p = 0.0173) and presence of distant metastases beside the brain (p = 0.0308) showed statistically significant associations with overall survival in multivariate Cox proportional hazards regression analysis. Median survival was 6.0 months if low KPS score was caused by cerebral disease and distant metastases in regions beyond the brain were absent, 3.3 months if low KPS score was caused by cerebral disease and distant metastases in regions beyond the brain were present, and 1.0 month if poor performance status resulted from extracerebral disease. Conclusions: Identification of the cause of low KPS score (cerebral vs. extracerebral) in patients with metastatic brain tumor(s) may be important for prediction of the outcome after radiosurgical treatment. If poor patient performance status without surgical indications is caused by intracranial tumor(s), SRS may be a reasonable treatment option

  18. Stereotactic Image-Guided Intensity Modulated Radiotherapy Using the HI-ART II Helical Tomotherapy System

    International Nuclear Information System (INIS)

    Holmes, Timothy W.; Hudes, Richard; Dziuba, Sylwester; Kazi, Abdul; Hall, Mark; Dawson, Dana

    2008-01-01

    The highly integrated adaptive radiation therapy (HI-ART II) helical tomotherapy unit is a new radiotherapy machine designed to achieve highly precise and accurate treatments at all body sites. The precision and accuracy of the HI-ART II is similar to that provided by stereotactic radiosurgery systems, hence the historical distinction between external beam radiotherapy and stereotactic procedures based on differing precision requirements is removed for this device. The objectives of this work are: (1) to describe stereotactic helical tomotherapy processes (SRS, SBRT); (2) to show that the precision and accuracy of the HI-ART meet the requirements defined for SRS and SBRT; and (3) to describe the clinical implementation of a stereotactic image-guided intensity modulated radiation therapy (IG-IMRT) system that incorporates optical motion management

  19. SU-F-T-593: Technical Treatment Accuracy in a Clinic of Fractionated Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Bisht, R; Kale, S; Natanasabapathi, G; Singh, M; Agarwal, D; Rath, G; Julka, P; Kumar, P; Thulkar, S; Garg, A; Sharma, B [All India Institute of Medical Sciences, Delhi, Delhi (India)

    2016-06-15

    Purpose: The purpose of this study is to estimate technical treatment accuracy in fractionated stereotactic radiosurgery (fSRS) using extend system (ES) of Gamma Knife (GK). Methods: The fSRS with GK relies on a patient specific re-locatable immobilization system. The reference treatment position is estimated using a digital probe and a repositioning check tool (RCT). The “calibration values” of RCT apertures were compared with measured values on RCT-QA tool to evaluate the standard error (SE) associated with RCT measurements. A treatment plan with single “4 mm collimator shot” was created to deliver a radiation dose of 5 Gy at the predefined plane of a newly designed in-house head-neck phantom. The plan was investigated using radiochromic EBT3 films. The stereotactic CT imaging of a designed mini CT phantom and distortion study of MR imaging, were combined to calculate imaging SE. The focal precision check for GK machine tolerance was performed using a central diode test tool. Results: Twenty observations of RCT and digital probe, shown the SE of +/−0.0186mm and +/−0.0002mm respectively. A mean positional shift of 0.2752mm (σ=0.0696mm) was observed for twenty similar treatment settings of head-neck phantom. The difference between radiological and predefined exposure point was 0.4650mm and 0.4270mm; for two independent experiments. The imaging studies showed a combined SE of +/− 0.1055mm. Twenty frequent runs of a diode test tool showed the tolerance SE of +/−0.0096mm. If, the measurements are considered to be at 95% of confidence level, an expanded uncertainty was evaluated as +/− 0.2371mm with our system. The positional shift, when combined with an expanded uncertainty, a trivial variation of 0.07mm (max) was observed in comparing resultant radiological precision through film investigations. Conclusion: The study proposes an expression of “technical treatment accuracy” within “known uncertainties” is rational in the estimation of

  20. Neurosurgical applications of ion beams

    Science.gov (United States)

    Fabrikant, Jacob I.; Levy, Richard P.; Phillips, Mark H.; Frankel, Kenneth A.; Lyman, John T.

    1989-04-01

    The program at Donner Pavilion has applied nuclear medicine research to the diagnosis and radiosurgical treatment of life-threatening intracranial vascular disorders that affect more than half a million Americans. Stereotactic heavy-charged-particle Bragg peak radiosurgery, using narrow beams of heavy ions, demonstrates superior biological and physical characteristics in brain over X-and γ-rays, viz., improved dose distribution in the Bragg peak and sharp lateral and distal borders and less scattering of the beam. Examination of CNS tissue response and alteration of cerebral blood-flow dynamics related to heavy-ion Bragg peak radiosurgery is carried out using three-dimensional treatment planning and quantitative imaging utilizing cerebral angiography, computerized tomography (CT), magnetic resonance imaging (MRI), cine-CT, xenon X-ray CT and positron emission tomography (PET). Also under examination are the physical properties of narrow heavy-ion beams for improving methods of dose delivery and dose distribution and for establishing clinical RBE/LET and dose-response relationships for human CNS tissues. Based on the evaluation and treatment with stereotactically directed narrow beams of heavy charged particles of over 300 patients, with cerebral angiography, CT scanning and MRI and PET scanning of selected patients, plus extensive clinical and neuroradiological followup, it appears that Stereotactic charged-particle Bragg peak radiosurgery obliterates intracranial arteriovenous malformations or protects against rebleeding with reduced morbidity and no mortality. Discussion will include the method of evaluation, the clinical research protocol, the Stereotactic neuroradiological preparation, treatment planning, the radiosurgery procedure and the protocol for followup. Emphasis will be placed on the neurological results, including the neuroradiological and clinical response and early and late delayed injury in brain leading to complications (including vasogenic edema

  1. Spine radiosurgery for the local treatment of spine metastases: Intensity-modulated radiotherapy, image guidance, clinical aspects and future directions

    International Nuclear Information System (INIS)

    Moraes, Fabio Ynoe de; Neves-Junior, Wellington Furtado Pimenta; Hanna, Samir Abdallah; Carvalho, Heloisa de Andrade; Laufer, Ilya

    2016-01-01

    Many cancer patients will develop spinal metastases. Local control is important for preventing neurologic compromise and to relieve pain. Stereotactic body radiotherapy or spinal radiosurgery is a new radiation therapy technique for spinal metastasis that can deliver a high dose of radiation to a tumor while minimizing the radiation delivered to healthy, neighboring tissues. This treatment is based on intensity-modulated radiotherapy, image guidance and rigid immobilization. Spinal radiosurgery is an increasingly utilized treatment method that improves local control and pain relief after delivering ablative doses of radiation. Here, we present a review highlighting the use of spinal radiosurgery for the treatment of metastatic tumors of the spine. The data used in the review were collected from both published studies and ongoing trials. We found that spinal radiosurgery is safe and provides excellent tumor control (up to 94% local control) and pain relief (up to 96%), independent of histology. Extensive data regarding clinical outcomes are available; however, this information has primarily been generated from retrospective and non randomized prospective series. Currently, two randomized trials are enrolling patients to study clinical applications of fractionation schedules spinal Radiosurgery. Additionally, a phase I clinical trial is being conducted to assess the safety of concurrent stereotactic body radiotherapy and ipilimumab for spinal metastases. Clinical trials to refine clinical indications and dose fractionation are ongoing. The concomitant use of targeted agents may produce better outcomes in the future. (author)

  2. Spine radiosurgery for the local treatment of spine metastases: Intensity-modulated radiotherapy, image guidance, clinical aspects and future directions

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Fabio Ynoe de; Neves-Junior, Wellington Furtado Pimenta; Hanna, Samir Abdallah; Carvalho, Heloisa de Andrade [Hospital Sirio-Libanes, Sao Paulo, SP (Brazil). Departamento de Radioterapia; Taunk, Neil Kanth; Yamada, Yoshiya [Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, New York, NY (United States); Laufer, Ilya, E-mail: fymoraes@gmail.com [Memorial Sloan Kettering Cancer Center, Department of Neurosurgery, New York, NY (United States)

    2016-02-15

    Many cancer patients will develop spinal metastases. Local control is important for preventing neurologic compromise and to relieve pain. Stereotactic body radiotherapy or spinal radiosurgery is a new radiation therapy technique for spinal metastasis that can deliver a high dose of radiation to a tumor while minimizing the radiation delivered to healthy, neighboring tissues. This treatment is based on intensity-modulated radiotherapy, image guidance and rigid immobilization. Spinal radiosurgery is an increasingly utilized treatment method that improves local control and pain relief after delivering ablative doses of radiation. Here, we present a review highlighting the use of spinal radiosurgery for the treatment of metastatic tumors of the spine. The data used in the review were collected from both published studies and ongoing trials. We found that spinal radiosurgery is safe and provides excellent tumor control (up to 94% local control) and pain relief (up to 96%), independent of histology. Extensive data regarding clinical outcomes are available; however, this information has primarily been generated from retrospective and non randomized prospective series. Currently, two randomized trials are enrolling patients to study clinical applications of fractionation schedules spinal Radiosurgery. Additionally, a phase I clinical trial is being conducted to assess the safety of concurrent stereotactic body radiotherapy and ipilimumab for spinal metastases. Clinical trials to refine clinical indications and dose fractionation are ongoing. The concomitant use of targeted agents may produce better outcomes in the future. (author)

  3. INTER- AND INTRAFRACTION MOTION FOR STEREOTACTIC RADIOSURGERY IN DOGS AND CATS USING A MODIFIED BRAINLAB FRAMELESS STEREOTACTIC MASK SYSTEM.

    Science.gov (United States)

    Dieterich, Sonja; Zwingenberger, Allison; Hansen, Katherine; Pfeiffer, Isabella; Théon, Alain; Kent, Michael S

    2015-01-01

    Precise and accurate patient positioning is necessary when doing stereotactic radiosurgery (SRS) to ensure adequate dosing to the tumor and sparing of normal tissues. This prospective cross-sectional study aimed to assess feasibility of a commercially available modified frameless SRS positioning system for use in veterinary radiotherapy patients with brain tumors. Fifty-one dogs and 12 cats were enrolled. Baseline and verification CT images were acquired. The verification CT images from 32 dogs and five cats had sufficient images for fusion to baseline CT images. A rigid box-based fusion was performed to determine interfraction motion. Forty-eight dogs and 11 cats were assessed for intrafraction motion by cine CT. Seventy percent of dogs and 60% of cats had interfraction 3D vector translational shifts >1 mm, with mean values of 1.9 mm in dogs, and 1.8 mm in cats. In dogs muscle wasting was weakly correlated with translational shifts. The maximum angular interfraction motion observed was 6.3° (roll), 3.5° (pitch), and 3.3° (yaw). There was no correlation between angular interfraction motion and weight, brachycephaly, or muscle wasting. Fifty-seven percent of dogs and 50% of cats had respiration-related intrafraction motion. Of these, 4.5% of dogs and 10% of cats had intrafraction motion >1 mm. This study demonstrates the modified Brainlab system is feasible for SRS in dogs and cats. The smaller cranial size and difference in anatomy increases setup uncertainty in some animals beyond limits usually accepted in SRS. Image-guided positioning is recommended to achieve clinically acceptable setup accuracy (<1 mm) for SRS. © 2015 American College of Veterinary Radiology.

  4. Robotic real-time translational and rotational head motion correction during frameless stereotactic radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xinmin; Belcher, Andrew H.; Grelewicz, Zachary; Wiersma, Rodney D., E-mail: rwiersma@uchicago.edu [Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, Illinois 60637 (United States)

    2015-06-15

    Purpose: To develop a control system to correct both translational and rotational head motion deviations in real-time during frameless stereotactic radiosurgery (SRS). Methods: A novel feedback control with a feed-forward algorithm was utilized to correct for the coupling of translation and rotation present in serial kinematic robotic systems. Input parameters for the algorithm include the real-time 6DOF target position, the frame pitch pivot point to target distance constant, and the translational and angular Linac beam off (gating) tolerance constants for patient safety. Testing of the algorithm was done using a 4D (XY Z + pitch) robotic stage, an infrared head position sensing unit and a control computer. The measured head position signal was processed and a resulting command was sent to the interface of a four-axis motor controller, through which four stepper motors were driven to perform motion compensation. Results: The control of the translation of a brain target was decoupled with the control of the rotation. For a phantom study, the corrected position was within a translational displacement of 0.35 mm and a pitch displacement of 0.15° 100% of the time. For a volunteer study, the corrected position was within displacements of 0.4 mm and 0.2° over 98.5% of the time, while it was 10.7% without correction. Conclusions: The authors report a control design approach for both translational and rotational head motion correction. The experiments demonstrated that control performance of the 4D robotic stage meets the submillimeter and subdegree accuracy required by SRS.

  5. Robotic real-time translational and rotational head motion correction during frameless stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Liu, Xinmin; Belcher, Andrew H.; Grelewicz, Zachary; Wiersma, Rodney D.

    2015-01-01

    Purpose: To develop a control system to correct both translational and rotational head motion deviations in real-time during frameless stereotactic radiosurgery (SRS). Methods: A novel feedback control with a feed-forward algorithm was utilized to correct for the coupling of translation and rotation present in serial kinematic robotic systems. Input parameters for the algorithm include the real-time 6DOF target position, the frame pitch pivot point to target distance constant, and the translational and angular Linac beam off (gating) tolerance constants for patient safety. Testing of the algorithm was done using a 4D (XY Z + pitch) robotic stage, an infrared head position sensing unit and a control computer. The measured head position signal was processed and a resulting command was sent to the interface of a four-axis motor controller, through which four stepper motors were driven to perform motion compensation. Results: The control of the translation of a brain target was decoupled with the control of the rotation. For a phantom study, the corrected position was within a translational displacement of 0.35 mm and a pitch displacement of 0.15° 100% of the time. For a volunteer study, the corrected position was within displacements of 0.4 mm and 0.2° over 98.5% of the time, while it was 10.7% without correction. Conclusions: The authors report a control design approach for both translational and rotational head motion correction. The experiments demonstrated that control performance of the 4D robotic stage meets the submillimeter and subdegree accuracy required by SRS

  6. The impact of whole-brain radiation therapy on the long-term control and morbidity of patients surviving more than one year after gamma knife radiosurgery for brain metastases

    International Nuclear Information System (INIS)

    Varlotto, John M.; Flickinger, John C.; Niranjan, Ajay; Bhatnagar, Ajay; Kondziolka, Douglas; Lunsford, L. Dade

    2005-01-01

    Purpose: To better analyze how whole-brain radiotherapy (WBXRT) affects long-term tumor control and toxicity from the initial stereotactic radiosurgery (SRS) for brain metastases, we studied these outcomes in patients who had survived at least 1 year from SRS. Methods and Materials: We evaluated the results of gamma knife radiosurgery for 160 brain metastases in 110 patients who were followed for a median of 18 months (range, 12-122 months) after SRS. Eighty-two patients had a solitary brain metastasis and 28 patients had multiple metastases. Seventy patients (116 tumors) were treated with initial radiosurgery and WBXRT, whereas 40 patients (44 lesions) initially received radiosurgery alone. Median treatment volume was 1.9 cc in the entire group, 2.3 cc in the WBXRT group, and 1.6 cc in the SRS alone group. Median tumor dose was 16 Gy (range, 12-21 Gy). Results: At 1, 3, and 5 years, local tumor control was 84.1% ± 5.5%, 68.6% ± 8.7%, and 68.6% ± 8.7% with SRS alone compared with 93.1% ± 2.4%, 87.7% ± 4.9%, and 65.7% ± 10.2%. with concurrent WBXRT and SRS (p = 0.0228, univariate). We found that WBXRT improved local control in patient subsets tumor volume ≥2 cc, peripheral dose ≤16 Gy, single metastases, nonradioresistant tumors, and lung cancer metastases (p = 0.0069, 0.0080, 0.0083, 0.0184, and 0.0348). Distal intracranial failure developed at 1, 3, and 5 years in 26.0% ± 7.1%, 74.5% ± 9.4%, and 74.5% ± 9.4% with SRS alone compared with 20.7% ± 4.9%, 49.0% ± 8.7%, and 61.8% ± 12.8% with concurrent WBXRT and SRS (p = 0.0657). We found a trend for improved distal intracranial control with WBXRT for only nonradioresistant tumors (p = 0.054). Postradiosurgery complications developed in 2.8% ± 1.2% and 10.7% ± 3.5% at 1 and 3-5 years and was unaffected by WBXRT (p = 0.7721). WBXRT did not improve survival in the entire series (p = 0.5027) or in any subsets. Conclusions: In this retrospective study of 1-year survivors of SRS for brain metastases, the

  7. Single-fraction Radiosurgery for Presumed Intracranial Meningiomas: Efficacy and Complications From a 22-Year Experience

    Energy Technology Data Exchange (ETDEWEB)

    Pollock, Bruce E., E-mail: pollock.bruce@mayo.edu [Department of Neurological Surgery, Mayo Clinic College of Medicine, Rochester, MN (United States); Department of Radiation Oncology, Mayo Clinic College of Medicine, Rochester, MN (United States); Stafford, Scott L. [Department of Radiation Oncology, Mayo Clinic College of Medicine, Rochester, MN (United States); Link, Michael J. [Department of Neurological Surgery, Mayo Clinic College of Medicine, Rochester, MN (United States); Garces, Yolanda I.; Foote, Robert L. [Department of Radiation Oncology, Mayo Clinic College of Medicine, Rochester, MN (United States)

    2012-08-01

    Purpose: To define the rate of tumor control and factors associated with radiation-related complications after single-fraction radiosurgery (SRS) for patients with imaging defined intracranial meningiomas. Materials and Methods: Retrospective review of 251 patients (192 women, 59 men) having SRS for imaging-defined intracranial meningiomas between 1990 and 2008. Excluded were patients with radiation-induced tumors, meningiomatosis, or neurofibromatosis. The mean patient age was 58.6 {+-} 13.4 years. The majority of tumors involved the skull base/tentorium (n = 210, 83.7%). The mean treatment volume was 7.7 {+-} 6.2 cm{sup 3}; the mean tumor margin dose was 15.8 {+-} 2.0 Gy. Follow-up (mean, 62.9 {+-} 43.9 months) was censored at last evaluation (n = 224), death (n = 22), or tumor resection (n = 5). Results: No patient died from tumor progression or radiation-related complications. Tumor size decreased in 181 patients (72.1%) and was unchanged in 67 patients (26.7%). Three patients (1.2%) had in-field tumor progression noted at 28, 145, and 150 months, respectively. No patient had a marginal tumor progression. The 3- and 10-year local control rate was 99.4%. One patient had distant tumor progression at 105 months and underwent repeat SRS. Thirty-one patients (12.4%) had either temporary (n = 8, 3.2%) or permanent (n = 23, 9.2%) symptomatic radiation-related complications including cranial nerve deficits (n = 14), headaches (n = 5), hemiparesis (n = 5), new/worsened seizure (n = 4), cyst-formation (n = 1), hemifacial spasm (n = 1), and stroke (n = 1). The 1- and 5-year complication rates were 8.3% and 11.5%, respectively. Radiation-related complications were associated with convexity/falx tumors (HR = 2.8, 95% CI 1.3-6.1, p = 0.009) and increasing tumor volume (HR = 1.05, 95% CI 1.0-1.1, p = 0.04) on multivariate analysis. No patient developed a radiation-induced tumor. Conclusions: Single-fraction SRS at the used dose range provides a high rate of tumor control for

  8. Single-fraction Radiosurgery for Presumed Intracranial Meningiomas: Efficacy and Complications From a 22-Year Experience

    International Nuclear Information System (INIS)

    Pollock, Bruce E.; Stafford, Scott L.; Link, Michael J.; Garces, Yolanda I.; Foote, Robert L.

    2012-01-01

    Purpose: To define the rate of tumor control and factors associated with radiation-related complications after single-fraction radiosurgery (SRS) for patients with imaging defined intracranial meningiomas. Materials and Methods: Retrospective review of 251 patients (192 women, 59 men) having SRS for imaging-defined intracranial meningiomas between 1990 and 2008. Excluded were patients with radiation-induced tumors, meningiomatosis, or neurofibromatosis. The mean patient age was 58.6 ± 13.4 years. The majority of tumors involved the skull base/tentorium (n = 210, 83.7%). The mean treatment volume was 7.7 ± 6.2 cm 3 ; the mean tumor margin dose was 15.8 ± 2.0 Gy. Follow-up (mean, 62.9 ± 43.9 months) was censored at last evaluation (n = 224), death (n = 22), or tumor resection (n = 5). Results: No patient died from tumor progression or radiation-related complications. Tumor size decreased in 181 patients (72.1%) and was unchanged in 67 patients (26.7%). Three patients (1.2%) had in-field tumor progression noted at 28, 145, and 150 months, respectively. No patient had a marginal tumor progression. The 3- and 10-year local control rate was 99.4%. One patient had distant tumor progression at 105 months and underwent repeat SRS. Thirty-one patients (12.4%) had either temporary (n = 8, 3.2%) or permanent (n = 23, 9.2%) symptomatic radiation-related complications including cranial nerve deficits (n = 14), headaches (n = 5), hemiparesis (n = 5), new/worsened seizure (n = 4), cyst-formation (n = 1), hemifacial spasm (n = 1), and stroke (n = 1). The 1- and 5-year complication rates were 8.3% and 11.5%, respectively. Radiation-related complications were associated with convexity/falx tumors (HR = 2.8, 95% CI 1.3–6.1, p = 0.009) and increasing tumor volume (HR = 1.05, 95% CI 1.0–1.1, p = 0.04) on multivariate analysis. No patient developed a radiation-induced tumor. Conclusions: Single-fraction SRS at the used dose range provides a high rate of tumor control for patients

  9. Gamma Knife radiosurgery for hemangioma of the cavernous sinus.

    Science.gov (United States)

    Lee, Cheng-Chia; Sheehan, Jason P; Kano, Hideyuki; Akpinar, Berkcan; Martinez-Alvarez, Roberto; Martinez-Moreno, Nuria; Guo, Wan-Yuo; Lunsford, L Dade; Liu, Kang-Du

    2017-05-01

    OBJECTIVE Cavernous sinus hemangiomas (CSHs) are rare vascular tumors. A direct microsurgical approach usually results in massive hemorrhage and incomplete tumor resection. Although stereotactic radiosurgery (SRS) has emerged as a therapeutic alternative to microsurgery, outcome studies are few. Authors of the present study evaluated the role of SRS for CSH. METHODS An international multicenter study was conducted to review outcome data in 31 patients with CSH. Eleven patients had initial microsurgery before SRS, and the other 20 patients (64.5%) underwent Gamma Knife SRS as the primary management for their CSH. Median age at the time of radiosurgery was 47 years, and 77.4% of patients had cranial nerve dysfunction before SRS. Patients received a median tumor margin dose of 12.6 Gy (range 12-19 Gy) at a median isodose of 55%. RESULTS Tumor regression was confirmed by imaging in all 31 patients, and all patients had greater than 50% reduction in tumor volume at 6 months post-SRS. No patient had delayed tumor growth, new cranial neuropathy, visual function deterioration, adverse radiation effects, or hypopituitarism after SRS. Twenty-four patients had presented with cranial nerve disorders before SRS, and 6 (25%) of them had gradual improvement. Four (66.7%) of the 6 patients with orbital symptoms had symptomatic relief at the last follow-up. CONCLUSIONS Stereotactic radiosurgery was effective in reducing the volume of CSH and attaining long-term tumor control in all patients at a median of 40 months. The authors' experience suggests that SRS is a reasonable primary and adjuvant treatment modality for patients in whom a CSH is diagnosed.

  10. Linear accelerator radiosurgery for trigeminal neuralgia: case report

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Hyong Geun [Dongguk University International Hospital, Goyang (Korea, Republic of)

    2006-06-15

    Trigeminal neuralgia is defined as an episodic electrical shock-like sensation in a dermatomal distribution of the trigeminal nerve. When medications fail to control pain, various procedures are used to attempt to control refractory pain. Of available procedures, stereotactic radiosurgery is the least invasive procedure and has been demonstrated to produce significant pain relief with minimal side effects. Recently, linear accelerators were introduced as a tool for radiosurgery of trigeminal neuralgia beneath the already accepted gamma unit. Author have experienced one case with trigeminal neuralgia treated with linear accelerator. The patient was treated with 85 Gy by means of 5 mm collimator directed to trigeminal nerve root entry zone. The patient obtained pain free without medication at 20 days after the procedure and remain pain free at 6 months after the procedure. He didn't experience facial numbness or other side effects.

  11. The Effect of Contouring Variability on Dosimetric Parameters for Brain Metastases Treated With Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Stanley, Julia; Dunscombe, Peter; Lau, Harold; Burns, Paul; Lim, Gerald; Liu, Hong-Wei; Nordal, Robert; Starreveld, Yves; Valev, Boris; Voroney, Jon-Paul; Spencer, David P.

    2013-01-01

    Purpose: To quantify the effect of contouring variation on stereotactic radiosurgery plan quality metrics for brain metastases. Methods and Materials: Fourteen metastases, each contoured by 8 physicians, formed the basis of this study. A template-based dynamic conformal 5-arc dose distribution was developed for each of the 112 contours, and each dose distribution was applied to the 7 other contours in each patient set. Radiation Therapy Oncology Group (RTOG) plan quality metrics and the Paddick conformity index were calculated for each of the 896 combinations of dose distributions and contours. Results: The ratio of largest to smallest contour volume for each metastasis varied from 1.25 to 4.47, with a median value of 1.68 (n=8). The median absolute difference in RTOG conformity index between the value for the reference contour and the values for the alternative contours was 0.35. The variation of the range of conformity index for all contours for a given tumor varied with the tumor size. Conclusions: The high degree of interobserver contouring variation strongly suggests that peer review or consultation should be adopted to standardize tumor volume prescription. Observer confidence was not reflected in contouring consistency. The impact of contouring variability on plan quality metrics, used as criteria for clinical trial protocol compliance, was such that the category of compliance was robust to interobserver effects only 70% of the time

  12. Hearing Outcomes After Stereotactic Radiosurgery for Unilateral Intracanalicular Vestibular Schwannomas: Implication of Transient Volume Expansion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young-Hoon [Department of Neurosurgery, Seoul National University Bundang Hospital, Seongnam-si (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Dong Gyu, E-mail: gknife@plaza.snu.ac.kr [Department of Neurosurgery, Seoul National University Hospital, Seoul (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Han, Jung Ho [Department of Neurosurgery, Seoul National University Bundang Hospital, Seongnam-si (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Chung, Hyun-Tai; Kim, In Kyung; Song, Sang Woo [Department of Neurosurgery, Seoul National University Hospital, Seoul (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Jeong-Hoon [Department of Neurosurgery, Seoul National University Bundang Hospital, Seongnam-si (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Jin Wook; Kim, Yong Hwy; Park, Chul-Kee [Department of Neurosurgery, Seoul National University Hospital, Seoul (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Chae-Yong [Department of Neurosurgery, Seoul National University Bundang Hospital, Seongnam-si (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Paek, Sun Ha; Jung, Hee-Won [Department of Neurosurgery, Seoul National University Hospital, Seoul (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2013-01-01

    Purpose: We evaluated the prognostic factors for hearing outcomes after stereotactic radiosurgery (SRS) for unilateral sporadic intracanalicular vestibular schwannomas (IC-VSs) as a clinical homogeneous group of VSs. Methods and Materials: Sixty consecutive patients with unilateral sporadic IC-VSs, defined as tumors in the internal acoustic canal, and serviceable hearing (Gardner-Roberson grade 1 or 2) were treated with SRS as an initial treatment. The mean tumor volume was 0.34 {+-} 0.03 cm{sup 3} (range, 0.03-1.00 cm{sup 3}), and the mean marginal dose was 12.2 {+-} 0.1 Gy (range, 11.5-13.0 Gy). The median follow-up duration was 62 months (range, 36-141 months). Results: The actuarial rates of serviceable hearing preservation were 70%, 63%, and 55% at 1, 2, and 5 years after SRS, respectively. In multivariate analysis, transient volume expansion of {>=}20% from initial tumor size was a statistically significant risk factor for loss of serviceable hearing and hearing deterioration (increase of pure tone average {>=}20 dB) (odds ratio = 7.638; 95% confidence interval, 2.317-25.181; P=.001 and odds ratio = 3.507; 95% confidence interval, 1.228-10.018; P=.019, respectively). The cochlear radiation dose did not reach statistical significance. Conclusions: Transient volume expansion after SRS for VSs seems to be correlated with hearing deterioration when defined properly in a clinically homogeneous group of patients.

  13. Is whole brain radiation therapy needed for all patients with newly diagnosed brain metastases undergoing stereotactic radiosurgery?

    International Nuclear Information System (INIS)

    Suh, John H.; Barnett, Gene H.; Miller, David W.; Kupelian, Patrick A.; Cohen, Bruce H.

    1997-01-01

    PURPOSE: Since whole brain radiation therapy (WBRT) carries risks for long term survivors of brain metastases, some have advocated the use of stereotactic radiosurgery (SRS) alone for patients with brain metastases. We retrospectively reviewed our results of stereotactic radiosurgery (SRS) with immediate or delayed WBRT. MATERIALS/METHODS: From March 1990 to December 1996, linear accelerator-based SRS was performed on patients with Karnofsky score ≥ 70 and asymptomatic or mildly symptomatic brain metastases < 4 cm diameter. After excluding those patients with recurrent disease, 87 patients with 106 metastatic lesions (72 pts- single or solitary lesion, 13 pts- 2 lesions, 1 pt- 3 lesions, and 1 pt- 5 lesions) remained for analysis. The use of WBRT was dependent on physician preference but was given to all patients who developed local or regional failure after SRS. Survival was measured from the date of SRS until death or last follow-up using Kaplan-Meier method. Freedom from progression (FFP) was defined as no local or regional brain failure on follow-up radiographs and was measured from the date of SRS. RESULTS: Prognostic variables (age, sex, initial KPS, systemic disease, and extent of surgical resection) were similar for the 40 patients in the immediate WBRT group (iWBRT) and for the 47 patients in the delayed WBRT group (dWBRT). With a median follow-up of 5.8 months, no significant difference in median survival (6.9 months for both groups) was noted. On multivariate analysis, absence of systemic disease (p=0.008) and KPS 90-100 (p=0.001) were the only significant predictors for survival. For the 29 patients with a minimum KPS of 90 and no systemic disease, the median survival was 17.8 months. For those patients with a solitary lesion (no systemic disease), there was a trend for better median survival for the iWBRT group (22.8 months) versus the dWBRT group (9.3 months), p=0.06. FFP data was available on 78 patients (97 lesions). A significant difference was

  14. Delayed Complications in Patients Surviving at Least 3 Years After Stereotactic Radiosurgery for Brain Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Masaaki, E-mail: BCD06275@nifty.com [Katsuta Hospital Mito GammaHouse, Hitachi-naka (Japan); Department of Neurosurgery, Tokyo Women' s Medical University Medical Center East, Tokyo (Japan); Kawabe, Takuya [Katsuta Hospital Mito GammaHouse, Hitachi-naka (Japan); Department of Neurosurgery, Kyoto Prefectural University of Medicine Graduate School of Medical Sciences, Kyoto (Japan); Higuchi, Yoshinori [Department of Neurosurgery, Chiba University Graduate School of Medicine, Chiba (Japan); Sato, Yasunori [Clinical Research Center, Chiba University Graduate School of Medicine, Chiba (Japan); Nariai, Tadashi [Department of Neurosurgery, Graduate School, Tokyo Medical and Dental University School of Medicine, Tokyo (Japan); Barfod, Bierta E. [Katsuta Hospital Mito GammaHouse, Hitachi-naka (Japan); Kasuya, Hidetoshi [Department of Neurosurgery, Tokyo Women' s Medical University Medical Center East, Tokyo (Japan); Urakawa, Yoichi [Katsuta Hospital Mito GammaHouse, Hitachi-naka (Japan)

    2013-01-01

    Purpose: Little is known about delayed complications after stereotactic radiosurgery in long-surviving patients with brain metastases. We studied the actual incidence and predictors of delayed complications. Patients and Methods: This was an institutional review board-approved, retrospective cohort study that used our database. Among our consecutive series of 2000 patients with brain metastases who underwent Gamma Knife radiosurgery (GKRS) from 1991-2008, 167 patients (8.4%, 89 women, 78 men, mean age 62 years [range, 19-88 years]) who survived at least 3 years after GKRS were studied. Results: Among the 167 patients, 17 (10.2%, 18 lesions) experienced delayed complications (mass lesions with or without cyst in 8, cyst alone in 8, edema in 2) occurring 24.0-121.0 months (median, 57.5 months) after GKRS. The actuarial incidences of delayed complications estimated by competing risk analysis were 4.2% and 21.2% at the 60th month and 120th month, respectively, after GKRS. Among various pre-GKRS clinical factors, univariate analysis demonstrated tumor volume-related factors: largest tumor volume (hazard ratio [HR], 1.091; 95% confidence interval [CI], 1.018-1.154; P=.0174) and tumor volume {<=}10 cc vs >10 cc (HR, 4.343; 95% CI, 1.444-12.14; P=.0108) to be the only significant predictors of delayed complications. Univariate analysis revealed no correlations between delayed complications and radiosurgical parameters (ie, radiosurgical doses, conformity and gradient indexes, and brain volumes receiving >5 Gy and >12 Gy). After GKRS, an area of prolonged enhancement at the irradiated lesion was shown to be a possible risk factor for the development of delayed complications (HR, 8.751; 95% CI, 1.785-157.9; P=.0037). Neurosurgical interventions were performed in 13 patients (14 lesions) and mass removal for 6 lesions and Ommaya reservoir placement for the other 8. The results were favorable. Conclusions: Long-term follow-up is crucial for patients with brain metastases

  15. Neurocognitive Function of Patients with Brain Metastasis Who Received Either Whole Brain Radiotherapy Plus Stereotactic Radiosurgery or Radiosurgery Alone

    International Nuclear Information System (INIS)

    Aoyama, Hidefumi; Tago, Masao; Kato, Norio; Toyoda, Tatsuya; Kenjyo, Masahiro; Hirota, Saeko; Shioura, Hiroki; Inomata, Taisuke; Kunieda, Etsuo; Hayakawa, Kazushige; Nakagawa, Keiichi; Kobashi, Gen; Shirato, Hiroki

    2007-01-01

    Purpose: To determine how the omission of whole brain radiotherapy (WBRT) affects the neurocognitive function of patients with one to four brain metastases who have been treated with stereotactic radiosurgery (SRS). Methods and Materials: In a prospective randomized trial between WBRT+SRS and SRS alone for patients with one to four brain metastases, we assessed the neurocognitive function using the Mini-Mental State Examination (MMSE). Of the 132 enrolled patients, MMSE scores were available for 110. Results: In the baseline MMSE analyses, statistically significant differences were observed for total tumor volume, extent of tumor edema, age, and Karnofsky performance status. Of the 92 patients who underwent the follow-up MMSE, 39 had a baseline MMSE score of ≤27 (17 in the WBRT+SRS group and 22 in the SRS-alone group). Improvements of ≥3 points in the MMSEs of 9 WBRT+SRS patients and 11 SRS-alone patients (p = 0.85) were observed. Of the 82 patients with a baseline MMSE score of ≥27 or whose baseline MMSE score was ≤26 but had improved to ≥27 after the initial brain treatment, the 12-, 24-, and 36-month actuarial free rate of the 3-point drop in the MMSE was 76.1%, 68.5%, and 14.7% in the WBRT+SRS group and 59.3%, 51.9%, and 51.9% in the SRS-alone group, respectively. The average duration until deterioration was 16.5 months in the WBRT+SRS group and 7.6 months in the SRS-alone group (p = 0.05). Conclusion: The results of the present study have revealed that, for most brain metastatic patients, control of the brain tumor is the most important factor for stabilizing neurocognitive function. However, the long-term adverse effects of WBRT on neurocognitive function might not be negligible

  16. Geometrically based optimization for extracranial radiosurgery

    International Nuclear Information System (INIS)

    Liu Ruiguo; Wagner, Thomas H; Buatti, John M; Modrick, Joseph; Dill, John; Meeks, Sanford L

    2004-01-01

    For static beam conformal intracranial radiosurgery, geometry of the beam arrangement dominates overall dose distribution. Maximizing beam separation in three dimensions decreases beam overlap, thus maximizing dose conformality and gradient outside of the target volume. Webb proposed arrangements of isotropically convergent beams that could be used as the starting point for a radiotherapy optimization process. We have developed an extracranial radiosurgery optimization method by extending Webb's isotropic beam arrangements to deliverable beam arrangements. This method uses an arrangement of N maximally separated converging vectors within the space available for beam delivery. Each bouquet of isotropic beam vectors is generated by a random sampling process that iteratively maximizes beam separation. Next, beam arrangement is optimized for critical structure avoidance while maintaining minimal overlap between beam entrance and exit pathways. This geometrically optimized beam set can then be used as a template for either conformal beam or intensity modulated extracranial radiosurgery. Preliminary results suggest that using this technique with conformal beam planning provides high plan conformality, a steep dose gradient outside of the tumour volume and acceptable critical structure avoidance in the majority of clinical cases

  17. Long-Term Outcomes of Stereotactic Radiosurgery for Treatment of Cavernous Sinus Meningiomas

    International Nuclear Information System (INIS)

    Santos, Marcos Antonio dos; Bustos Pérez de Salcedo, José; Gutiérrez Diaz, José Angel; Calvo, Felipe A.; Samblás, José; Marsiglia, Hugo; Sallabanda, Kita

    2011-01-01

    Purpose: Patients with cavernous sinus meningiomas (CSM) have an elevated risk of surgical morbidity and mortality. Recurrence is often observed after partial resection. Stereotactic radiosurgery (SRS), either alone or combined with surgery, represents an important advance in CSM management, but long-term results are lacking. Methods and Materials: A total of 88 CSM patients, treated from January 1991 to December 2005, were retrospectively reviewed. The mean follow-up was 86.8 months (range, 17.1–179.4 months). Among the patients, 22 were followed for more than 10 years. There was a female predominance (84.1%). The age varied from 16 to 90 years (mean, 51.6). In all, 47 patients (53.4%) received SRS alone, and 41 patients (46.6%) had undergone surgery before SRS. A dose of 14 Gy was prescribed to isodose curves from 50% to 90%. In 25 patients (28.4%), as a result of the proximity to organs at risk, the prescribed dose did not completely cover the target. Results: After SRS, 65 (73.8%) patients presented with tumor volume reduction; 14 (15.9%) remained stable, and 9 (10.2%) had tumor progression. The progression-free survival was 92.5% at 5 years, and 82.5% at 10 years. Age, sex, maximal diameter of the treated tumor, previous surgery, and complete target coverage did not show significant associations with prognosis. Among the 88 treated patients, 17 experienced morbidity that was related to SRS, and 6 of these patients spontaneously recovered. Conclusions: SRS is an effective and safe treatment for CSM, feasible either in the primary or the postsurgical setting. Incomplete coverage of the target did not worsen outcomes. More than 80% of the patients remained free of disease progression during long-term follow-up.

  18. Long-Term Outcomes of Stereotactic Radiosurgery for Treatment of Cavernous Sinus Meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcos Antonio dos, E-mail: marcosrxt@gmail.com [Radiotherapy Department, Instituto Madrileno de Oncologia/Grupo IMO, Madrid (Spain); Bustos Perez de Salcedo, Jose; Gutierrez Diaz, Jose Angel [Radiotherapy Department, Instituto Madrileno de Oncologia/Grupo IMO, Madrid (Spain); Neurosurgery Department, Sanatorio San Francisco de Asis, Madrid (Spain); Calvo, Felipe A. [Radiotherapy Department, Instituto Madrileno de Oncologia/Grupo IMO, Madrid (Spain); Department of Oncology, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Samblas, Jose [Radiotherapy Department, Instituto Madrileno de Oncologia/Grupo IMO, Madrid (Spain); Neurosurgery Department, Sanatorio San Francisco de Asis, Madrid (Spain); Marsiglia, Hugo [Radiotherapy Department, Instituto Madrileno de Oncologia/Grupo IMO, Madrid (Spain); Sallabanda, Kita [Radiotherapy Department, Instituto Madrileno de Oncologia/Grupo IMO, Madrid (Spain); Neurosurgery Department, Sanatorio San Francisco de Asis, Madrid (Spain)

    2011-12-01

    Purpose: Patients with cavernous sinus meningiomas (CSM) have an elevated risk of surgical morbidity and mortality. Recurrence is often observed after partial resection. Stereotactic radiosurgery (SRS), either alone or combined with surgery, represents an important advance in CSM management, but long-term results are lacking. Methods and Materials: A total of 88 CSM patients, treated from January 1991 to December 2005, were retrospectively reviewed. The mean follow-up was 86.8 months (range, 17.1-179.4 months). Among the patients, 22 were followed for more than 10 years. There was a female predominance (84.1%). The age varied from 16 to 90 years (mean, 51.6). In all, 47 patients (53.4%) received SRS alone, and 41 patients (46.6%) had undergone surgery before SRS. A dose of 14 Gy was prescribed to isodose curves from 50% to 90%. In 25 patients (28.4%), as a result of the proximity to organs at risk, the prescribed dose did not completely cover the target. Results: After SRS, 65 (73.8%) patients presented with tumor volume reduction; 14 (15.9%) remained stable, and 9 (10.2%) had tumor progression. The progression-free survival was 92.5% at 5 years, and 82.5% at 10 years. Age, sex, maximal diameter of the treated tumor, previous surgery, and complete target coverage did not show significant associations with prognosis. Among the 88 treated patients, 17 experienced morbidity that was related to SRS, and 6 of these patients spontaneously recovered. Conclusions: SRS is an effective and safe treatment for CSM, feasible either in the primary or the postsurgical setting. Incomplete coverage of the target did not worsen outcomes. More than 80% of the patients remained free of disease progression during long-term follow-up.

  19. Acceptance, commissioning and quality control in radiosurgery

    International Nuclear Information System (INIS)

    Toreti, Dalila Luzia

    2009-01-01

    Stereotactic Radiosurgery is a treatment technique that uses narrow beams of radiation focused with great accuracy in a small lesion. The introduction of micro multi leaf collimators (mMLC) allows this technique to reach a higher degree of dose conformation of the target lesion allowing a smaller irradiation of critical structures and normal tissues. This paper presents the results of the acceptance tests and commissioning of a Varian 6EX linear accelerator dedicated to radiosurgery associated with the BrainLab micro multi leaf collimator installed in the Hospital das Clinicas da Faculdade de Medicina da USP (HC-FMUSP) and establish feasible quality assurance program for the services that employ this special technique. The results of the acceptance tests were satisfactory and are willing with the specifications provided by the manufacturer and the commissioning tests were within the international recommendations. The tests and measures that are part of quality control process should be specific to each treatment unit, and the need, frequency and levels of tolerance

  20. Hybrid surgery-radiosurgery therapy for metastatic epidural spinal cord compression: A prospective evaluation using patient-reported outcomes.

    Science.gov (United States)

    Barzilai, Ori; Amato, Mary-Kate; McLaughlin, Lily; Reiner, Anne S; Ogilvie, Shahiba Q; Lis, Eric; Yamada, Yoshiya; Bilsky, Mark H; Laufer, Ilya

    2018-05-01

    Patient-reported outcomes (PRO) represent an important measure of cancer therapy effect. For patients with metastatic epidural spinal cord compression (MESCC), hybrid therapy using separation surgery and stereotactic radiosurgery preserves neurologic function and provides tumor control. There is currently a paucity of data reporting PRO after such combined modality therapy for MESCC. Delineation of hybrid surgery-radiosurgery therapy effect on PRO validates the hybrid approach as an effective therapy resulting in meaningful symptom relief. Brief Pain Inventory (BPI) and MD Anderson Symptom Inventory-Spine Tumor (MDASI-SP), PROs validated in the cancer population, were prospectively collected. Patients with MESCC who underwent separation surgery followed by stereotactic radiosurgery were included. Separation surgery included a posterolateral approach without extensive cytoreductive tumor excision. A median postoperative radiosurgery dose of 2700 cGy was delivered. The change in PRO 3 months after the hybrid therapy represented the primary study outcome. Preoperative and postoperative evaluations were analyzed using the Wilcoxon signed-rank test for matched pairs. One hundred eleven patients were included. Hybrid therapy resulted in a significant reduction in the BPI items "worst" and "right now" pain ( P < .0001), and in all BPI constructs (severity, interference with daily activities, and pain experience, P < .001). The MDASI-SP demonstrated reduction in spine-specific pain severity and interference with general activity ( P < .001), along with decreased symptom interference ( P < .001). Validated PRO instruments showed that in patients with MESCC, hybrid therapy with separation surgery and radiosurgery results in a significant decrease in pain severity and symptom interference. These prospective data confirm the benefit of hybrid therapy for treatment of MESCC and should facilitate referral of patients with MESCC for surgical evaluation.

  1. Knowledge Modeling for the Outcome of Brain Stereotactic Radiosurgery

    Science.gov (United States)

    Hauck, Jillian E.

    Purpose: To build a model that will predict the survival time for patients that were treated with stereotactic radiosurgery for brain metastases using support vector machine (SVM) regression. Methods and Materials: This study utilized data from 481 patients, which were equally divided into training and validation datasets randomly. The SVM model used a Gaussian RBF function, along with various parameters, such as the size of the epsilon insensitive region and the cost parameter (C) that are used to control the amount of error tolerated by the model. The predictor variables for the SVM model consisted of the actual survival time of the patient, the number of brain metastases, the graded prognostic assessment (GPA) and Karnofsky Performance Scale (KPS) scores, prescription dose, and the largest planning target volume (PTV). The response of the model is the survival time of the patient. The resulting survival time predictions were analyzed against the actual survival times by single parameter classification and two-parameter classification. The predicted mean survival times within each classification were compared with the actual values to obtain the confidence interval associated with the model's predictions. In addition to visualizing the data on plots using the means and error bars, the correlation coefficients between the actual and predicted means of the survival times were calculated during each step of the classification. Results: The number of metastases and KPS scores, were consistently shown to be the strongest predictors in the single parameter classification, and were subsequently used as first classifiers in the two-parameter classification. When the survival times were analyzed with the number of metastases as the first classifier, the best correlation was obtained for patients with 3 metastases, while patients with 4 or 5 metastases had significantly worse results. When the KPS score was used as the first classifier, patients with a KPS score of 60 and

  2. A nomogram for predicting distant brain failure in patients treated with gamma knife stereotactic radiosurgery without whole brain radiotherapy

    Science.gov (United States)

    Ayala-Peacock, Diandra N.; Peiffer, Ann M.; Lucas, John T.; Isom, Scott; Kuremsky, J. Griff; Urbanic, James J.; Bourland, J. Daniel; Laxton, Adrian W.; Tatter, Stephen B.; Shaw, Edward G.; Chan, Michael D.

    2014-01-01

    Background We review our single institution experience to determine predictive factors for early and delayed distant brain failure (DBF) after radiosurgery without whole brain radiotherapy (WBRT) for brain metastases. Materials and methods Between January 2000 and December 2010, a total of 464 patients were treated with Gamma Knife stereotactic radiosurgery (SRS) without WBRT for primary management of newly diagnosed brain metastases. Histology, systemic disease, RPA class, and number of metastases were evaluated as possible predictors of DBF rate. DBF rates were determined by serial MRI. Kaplan–Meier method was used to estimate rate of DBF. Multivariate analysis was performed using Cox Proportional Hazard regression. Results Median number of lesions treated was 1 (range 1–13). Median time to DBF was 4.9 months. Twenty-seven percent of patients ultimately required WBRT with median time to WBRT of 5.6 months. Progressive systemic disease (χ2= 16.748, P < .001), number of metastases at SRS (χ2 = 27.216, P < .001), discovery of new metastases at time of SRS (χ2 = 9.197, P < .01), and histology (χ2 = 12.819, P < .07) were factors that predicted for earlier time to distant failure. High risk histologic subtypes (melanoma, her2 negative breast, χ2 = 11.020, P < .001) and low risk subtypes (her2 + breast, χ2 = 11.343, P < .001) were identified. Progressive systemic disease (χ2 = 9.549, P < .01), number of brain metastases (χ2 = 16.953, P < .001), minimum SRS dose (χ2 = 21.609, P < .001), and widespread metastatic disease (χ2 = 29.396, P < .001) were predictive of shorter time to WBRT. Conclusion Systemic disease, number of metastases, and histology are factors that predict distant failure rate after primary radiosurgical management of brain metastases. PMID:24558022

  3. Hematological Toxicity After Robotic Stereotactic Body Radiosurgery for Treatment of Metastatic Gynecologic Malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Kunos, Charles A., E-mail: charles.kunos@UHhospitals.org [Department of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States); Debernardo, Robert [Department of Obstetrics and Gynecology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States); Radivoyevitch, Tomas [Department of Epidemiology and Biostatistics, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States); Fabien, Jeffrey; Dobbins, Donald C.; Zhang Yuxia; Brindle, James [Department of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States)

    2012-09-01

    Purpose: To evaluate hematological toxicity after robotic stereotactic body radiosurgery (SBRT) for treatment of women with metastatic abdominopelvic gynecologic malignancies. Methods and Materials: A total of 61 women with stage IV gynecologic malignancies treated with abdominopelvic SBRT were analyzed after ablative radiation (2400 cGy/3 divided consecutive daily doses) delivered by a robotic-armed Cyberknife SBRT system. Abdominopelvic bone marrow was identified using computed tomography-guided contouring. Fatigue and hematologic toxicities were graded by retrospective assignment of common toxicity criteria for adverse events (version 4.0). Bone marrow volume receiving 1000 cGy (V10) was tested for association with post-therapy (median 32 days [25%-75% quartile, 28-45 days]) white- or red-cell counts, hemoglobin levels, and platelet counts as marrow toxicity surrogates. Results: In all, 61 women undergoing abdominopelvic SBRT had a median bone marrow V10 of 2% (25%-75% quartile: 0%-8%). Fifty-seven (93%) of 61 women had received at least 1 pre-SBRT marrow-taxing chemotherapy regimen for metastatic disease. Bone marrow V10 did not associate with hematological adverse events. In all, 15 grade 2 (25%) and 2 grade 3 (3%) fatigue symptoms were self-reported among the 61 women within the first 10 days post-therapy, with fatigue resolved spontaneously in all 17 women by 30 days post-therapy. Neutropenia was not observed. Three (5%) women had a grade 1 drop in hemoglobin level to <10.0 g/dL. Single grade 1, 2, and 3 thrombocytopenias were documented in 3 women. Conclusions: Abdominopelvic SBRT provided ablative radiation dose to cancer targets without increased bone marrow toxicity. Abdominopelvic SBRT for metastatic gynecologic malignancies warrants further study.

  4. Phase II clinical trial of robotic stereotactic body radiosurgery for metastatic gynecologic malignancies

    Directory of Open Access Journals (Sweden)

    Charles eKunos

    2012-12-01

    Full Text Available Background Recurrent gynecologic cancers are often difficult to manage without significant morbidity. We conducted a phase II study to assess the safety and the efficacy of ablative robotic stereotactic body radiosurgery (SBRT in women with metastatic gynecologic cancers. Methods A total of 50 patients with recurrent gynecologic cancer who had single or multiple (≤4 metastases underwent robotic-armed Cyberknife SBRT (24Gy/3 daily doses. Toxicities were graded prospectively by common toxicity criteria for adverse events (version 4.0. SBRT target responses were recorded following RECIST criteria (version 1.0. Rates of clinical benefit for SBRT and non-radiosurgical disease relapse were calculated. Disease-free and overall survivals were estimated by the Kaplan-Meier method and the Cox proportional hazards model was used to control for prognostic variables.Findings SBRT was safely delivered, with 49 (98% of 50 patients completing three prescribed fractions. The most frequent grade 2 or higher adverse events attributed to SBRT included fatigue (16%, nausea (8% and diarrhea (4%. One (2% grade 4 hyperbilirubinemia occurred. SBRT target response was 96% (48 of 50 patients. A 6-month clinical benefit was recorded in 34 (68% [95% CI, 53.2, 80.1] patients. No SBRT-targeted disease progressed. Non-radiosurgical disease relapse occurred in 31 (62% patients. Median disease-free survival was 7.8 months (95% CI, 4.0, 11.6. Median overall survival was 20.2 months (95% CI, 10.9, 29.5.Interpretation SBRT safely controlled metastatic gynecologic cancer targets. Given an observed high rate of non-radiosurgical disease relapse, a phase I trial assessing co-administration of SBRT and cytotoxic chemotherapy is underway.Funding Case Comprehensive Cancer Center

  5. Phase II Clinical Trial of Robotic Stereotactic Body Radiosurgery for Metastatic Gynecologic Malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Kunos, Charles A.; Brindle, James [Department of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University, School of Medicine, Cleveland, OH (United States); Waggoner, Steven; Zanotti, Kristine; Resnick, Kimberly; Fusco, Nancy; Adams, Ramon; Debernardo, Robert, E-mail: charles.kunos@uhhospitals.org [Division of Gynecologic Oncology, Department of Obstetrics and Gynecology, University Hospitals Case Medical Center and Case Western Reserve University, School of Medicine, Cleveland, OH (United States)

    2012-12-05

    Background: Recurrent gynecologic cancers are often difficult to manage without significant morbidity. We conducted a phase II study to assess the safety and the efficacy of ablative robotic stereotactic body radiosurgery (SBRT) in women with metastatic gynecologic cancers. Methods: A total of 50 patients with recurrent gynecologic cancer who had single or multiple (≤4) metastases underwent robotic-armed Cyberknife SBRT (24Gy/3 daily doses). Toxicities were graded prospectively by common toxicity criteria for adverse events (version 4.0). SBRT target responses were recorded following RECIST criteria (version 1.0). Rates of clinical benefit for SBRT and non-radiosurgical disease relapse were calculated. Disease-free and overall survivals were estimated by the Kaplan–Meier method and the Cox proportional hazards model was used to control for prognostic variables. Findings: SBRT was safely delivered, with 49 (98%) of 50 patients completing three prescribed fractions. The most frequent grade 2 or higher adverse events attributed to SBRT included fatigue (16%), nausea (8%), and diarrhea (4%). One (2%) grade four hyperbilirubinemia occurred. SBRT target response was 96% (48 of 50 patients). A 6-month clinical benefit was recorded in 34 [68% (95% CI, 53.2, 80.1)] patients. No SBRT targeted disease progressed. Non-radiosurgical disease relapse occurred in 31 (62%) patients. Median disease-free survival was 7.8 months (95% CI, 4.0, 11.6). Median overall survival was 20.2 months (95% CI, 10.9, 29.5). Interpretation: SBRT safely controlled metastatic gynecologic cancer targets. Given an observed high rate of non-radiosurgical disease relapse, a phase I trial assessing co-administration of SBRT and cytotoxic chemotherapy is underway. Funding: Case Comprehensive Cancer Center.

  6. Hematological Toxicity After Robotic Stereotactic Body Radiosurgery for Treatment of Metastatic Gynecologic Malignancies

    International Nuclear Information System (INIS)

    Kunos, Charles A.; Debernardo, Robert; Radivoyevitch, Tomas; Fabien, Jeffrey; Dobbins, Donald C.; Zhang Yuxia; Brindle, James

    2012-01-01

    Purpose: To evaluate hematological toxicity after robotic stereotactic body radiosurgery (SBRT) for treatment of women with metastatic abdominopelvic gynecologic malignancies. Methods and Materials: A total of 61 women with stage IV gynecologic malignancies treated with abdominopelvic SBRT were analyzed after ablative radiation (2400 cGy/3 divided consecutive daily doses) delivered by a robotic-armed Cyberknife SBRT system. Abdominopelvic bone marrow was identified using computed tomography-guided contouring. Fatigue and hematologic toxicities were graded by retrospective assignment of common toxicity criteria for adverse events (version 4.0). Bone marrow volume receiving 1000 cGy (V10) was tested for association with post-therapy (median 32 days [25%-75% quartile, 28-45 days]) white- or red-cell counts, hemoglobin levels, and platelet counts as marrow toxicity surrogates. Results: In all, 61 women undergoing abdominopelvic SBRT had a median bone marrow V10 of 2% (25%-75% quartile: 0%-8%). Fifty-seven (93%) of 61 women had received at least 1 pre-SBRT marrow-taxing chemotherapy regimen for metastatic disease. Bone marrow V10 did not associate with hematological adverse events. In all, 15 grade 2 (25%) and 2 grade 3 (3%) fatigue symptoms were self-reported among the 61 women within the first 10 days post-therapy, with fatigue resolved spontaneously in all 17 women by 30 days post-therapy. Neutropenia was not observed. Three (5%) women had a grade 1 drop in hemoglobin level to <10.0 g/dL. Single grade 1, 2, and 3 thrombocytopenias were documented in 3 women. Conclusions: Abdominopelvic SBRT provided ablative radiation dose to cancer targets without increased bone marrow toxicity. Abdominopelvic SBRT for metastatic gynecologic malignancies warrants further study.

  7. Phase II Clinical Trial of Robotic Stereotactic Body Radiosurgery for Metastatic Gynecologic Malignancies

    International Nuclear Information System (INIS)

    Kunos, Charles A.; Brindle, James; Waggoner, Steven; Zanotti, Kristine; Resnick, Kimberly; Fusco, Nancy; Adams, Ramon; Debernardo, Robert

    2012-01-01

    Background: Recurrent gynecologic cancers are often difficult to manage without significant morbidity. We conducted a phase II study to assess the safety and the efficacy of ablative robotic stereotactic body radiosurgery (SBRT) in women with metastatic gynecologic cancers. Methods: A total of 50 patients with recurrent gynecologic cancer who had single or multiple (≤4) metastases underwent robotic-armed Cyberknife SBRT (24Gy/3 daily doses). Toxicities were graded prospectively by common toxicity criteria for adverse events (version 4.0). SBRT target responses were recorded following RECIST criteria (version 1.0). Rates of clinical benefit for SBRT and non-radiosurgical disease relapse were calculated. Disease-free and overall survivals were estimated by the Kaplan–Meier method and the Cox proportional hazards model was used to control for prognostic variables. Findings: SBRT was safely delivered, with 49 (98%) of 50 patients completing three prescribed fractions. The most frequent grade 2 or higher adverse events attributed to SBRT included fatigue (16%), nausea (8%), and diarrhea (4%). One (2%) grade four hyperbilirubinemia occurred. SBRT target response was 96% (48 of 50 patients). A 6-month clinical benefit was recorded in 34 [68% (95% CI, 53.2, 80.1)] patients. No SBRT targeted disease progressed. Non-radiosurgical disease relapse occurred in 31 (62%) patients. Median disease-free survival was 7.8 months (95% CI, 4.0, 11.6). Median overall survival was 20.2 months (95% CI, 10.9, 29.5). Interpretation: SBRT safely controlled metastatic gynecologic cancer targets. Given an observed high rate of non-radiosurgical disease relapse, a phase I trial assessing co-administration of SBRT and cytotoxic chemotherapy is underway. Funding: Case Comprehensive Cancer Center.

  8. Stereotactic radiotherapy following surgery for brain metastasis: Predictive factors for local control and radionecrosis.

    Science.gov (United States)

    Doré, M; Martin, S; Delpon, G; Clément, K; Campion, L; Thillays, F

    2017-02-01

    To evaluate local control and adverse effects after postoperative hypofractionated stereotactic radiosurgery in patients with brain metastasis. We reviewed patients who had hypofractionated stereotactic radiosurgery (7.7Gy×3 prescribed to the 70% isodose line, with 2mm planning target volume margin) following resection from March 2008 to January 2014. The primary endpoint was local failure defined as recurrence within the surgical cavity. Secondary endpoints were distant failure rates and the occurrence of radionecrosis. Out of 95 patients, 39.2% had metastatic lesions from a non-small cell lung cancer primary tumour. The median Graded Prognostic Assessment score was 3 (48% of patients). One-year local control rates were 84%. Factors associated with improved local control were no cavity enhancement on pre-radiation MRI (P<0.00001), planning target volume less than 12cm 3 (P=0.005), Graded Prognostic Assessment score 2 or above (P=0.009). One-year distant cerebral control rates were 56%. Thirty-three percent of patients received whole brain radiation therapy. Histologically proven radionecrosis of brain tissue occurred in 7.2% of cases. The size of the preoperative lesion and the volume of healthy brain tissue receiving 21Gy (V 21 ) were both predictive of the incidence of radionecrosis (P=0.010 and 0.036, respectively). Adjuvant hypofractionated stereotactic radiosurgery to the postoperative cavity in patients with brain metastases results in excellent local control in selected patients, helps delay the use of whole brain radiation, and is associated with a relatively low risk of radionecrosis. Copyright © 2016 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  9. Gamma knife radiosurgery in movement disorders: Indications and limitations.

    Science.gov (United States)

    Higuchi, Yoshinori; Matsuda, Shinji; Serizawa, Toru

    2017-01-01

    Functional radiosurgery has advanced steadily during the past half century since the development of the gamma knife technique for treating intractable cancer pain. Applications of radiosurgery for intracranial diseases have increased with a focus on understanding radiobiology. Currently, the use of gamma knife radiosurgery to ablate deep brain structures is not widespread because visualization of the functional targets remains difficult despite the increased availability of advanced neuroimaging technology. Moreover, most existing reports have a small sample size or are retrospective. However, increased experience with intraoperative neurophysiological evaluations in radiofrequency thalamotomy and deep brain stimulation supports anatomical and neurophysiological approaches to the ventralis intermedius nucleus. Two recent prospective studies have promoted the clinical application of functional radiosurgery for movement disorders. For example, unilateral gamma knife thalamotomy is a potential alternative to radiofrequency thalamotomy and deep brain stimulation techniques for intractable tremor patients with contraindications for surgery. Despite the promising efficacy of gamma knife thalamotomy, however, these studies did not include sufficient follow-up to confirm long-term effects. Herein, we review the radiobiology literature, various techniques, and the treatment efficacy of gamma knife radiosurgery for patients with movement disorders. Future research should focus on randomized controlled studies and long-term effects. © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.

  10. Analyses of multi-irradiation film for system alignments in stereotactic radiotherapy (SRT) and radiosurgery (SRS)

    International Nuclear Information System (INIS)

    Jen-San Tsai

    1996-01-01

    In stereotactic radiosurgery, a seven-irradiation film was used to define any discrepancy between the beam and target centres. A mathematical model based on the linac alignment and target set-up was developed to diagnose the discrepancies of the seven-irradiation film between the beam and simulation target centres. From the measured data of the multi-irradiation film, this mathematical model leads to five parameters in seven equations. Twin computer codes were employed to solve the five parameters from the seven equations. By feeding the discrepancy data into the two computer codes, the sources of the target-to-beam discrepancy were revealed. From these decoded sources, the target coordinates were adjusted and then the seven-irradiation film procedure was repeated. This discrepancy thus obtained was found to be drastically reduced. Some decoded parameters were consistently verified by direct measurements. This demonstrates that the present mathematical model and computer code do reveal the causes of the target-to-beam misalignment and gantry sag. In a further effort to test the feasibility of the mathematical model and the computer codes, the target's lateral coordinate was deliberately offset by 1.5 mm and then another seven-irradiation film was taken. By inserting these discrepancies into the computer codes, it was found that the deviation was consistent with the intentional offset. In addition, the mathematical model and computer codes are applicable to any multi-irradiation technique. (author)

  11. Hearing Outcomes After Stereotactic Radiosurgery for Unilateral Intracanalicular Vestibular Schwannomas: Implication of Transient Volume Expansion

    International Nuclear Information System (INIS)

    Kim, Young-Hoon; Kim, Dong Gyu; Han, Jung Ho; Chung, Hyun-Tai; Kim, In Kyung; Song, Sang Woo; Park, Jeong-Hoon; Kim, Jin Wook; Kim, Yong Hwy; Park, Chul-Kee; Kim, Chae-Yong; Paek, Sun Ha; Jung, Hee-Won

    2013-01-01

    Purpose: We evaluated the prognostic factors for hearing outcomes after stereotactic radiosurgery (SRS) for unilateral sporadic intracanalicular vestibular schwannomas (IC-VSs) as a clinical homogeneous group of VSs. Methods and Materials: Sixty consecutive patients with unilateral sporadic IC-VSs, defined as tumors in the internal acoustic canal, and serviceable hearing (Gardner-Roberson grade 1 or 2) were treated with SRS as an initial treatment. The mean tumor volume was 0.34 ± 0.03 cm 3 (range, 0.03-1.00 cm 3 ), and the mean marginal dose was 12.2 ± 0.1 Gy (range, 11.5-13.0 Gy). The median follow-up duration was 62 months (range, 36-141 months). Results: The actuarial rates of serviceable hearing preservation were 70%, 63%, and 55% at 1, 2, and 5 years after SRS, respectively. In multivariate analysis, transient volume expansion of ≥20% from initial tumor size was a statistically significant risk factor for loss of serviceable hearing and hearing deterioration (increase of pure tone average ≥20 dB) (odds ratio = 7.638; 95% confidence interval, 2.317-25.181; P=.001 and odds ratio = 3.507; 95% confidence interval, 1.228-10.018; P=.019, respectively). The cochlear radiation dose did not reach statistical significance. Conclusions: Transient volume expansion after SRS for VSs seems to be correlated with hearing deterioration when defined properly in a clinically homogeneous group of patients.

  12. Gamma knife radiosurgery for arteriovenous malformation in children

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Takayuki; Kobayashi, Tatsuya [Komaki City Hospital, Aichi (Japan)

    1995-04-01

    Intracranial arteriovenous malformations (AVM) of 38 children were treated by gamma knife radiosurgery. Their clinical courses and the effect of the treatment in 19 patients who had angiographies are described. There were 21 boys and 17 girls with a mean age of 11.2 years. The initial signs and symptoms were: intracranial hemorrhage in 32, seizures in 4, and headache in 2. Prior to the radiosurgery, craniotomy was performed in 10 patients, ventricular drainage, in 8, ventriculoperitoneal shunting in 4, and intravascular embolization in 3. The AVM was in the parietal lobe in 8 patients, in the thalamus in 7, in the occipital lobe in 5, in the temporal lobe in 4, in the basal ganglia in 4, in the corpus callosum in 3, and in other locations in 8. The mean diameter of the nidus was 18.9 mm. According to Spetzler`s classification of AVM, 23 (60.5%) were grade III, 10 were grade II, 3 were grade IV, and 2 were grade VI. The mean maximum dose was 36.3 Gy, and the mean peripheral dose was 20.2 Gy. Follow-up angiography was done in 19 patients during a mean follow-up period of 14.9 months. Complete occlusion of the nidus was obtained within 1 year in 10 of 15 patients (67%). All 6 patients who underwent angiography 2 years after treatment showed complete obliteration of the AVM. Only 1 patient developed hemiparesis due to radiation necrosis. It is considered that occlusion of AVMs by gamma knife radiosurgery is probably more effective and safer in children than in adults. (author).

  13. Therapeutic cranial nerve irradiation: results from a multi-center dose response study of radiosurgery for trigeminal neuralgia

    Energy Technology Data Exchange (ETDEWEB)

    Kondziolka, D; Flickinger, J; Lunsford, L D; Young, R; Vermeulen, S; Duma, C; Jacques, D B; Rand, R; Regis, J; Peragut, J C; Epstein, M H; Lindquist, C

    1995-07-01

    Purpose/Objective: We performed a multi-institution study to evaluate the technique, dose-selection parameters, and results of gamma knife stereotactic radiosurgery in the management of trigeminal neuralgia. We hypothesized that MRI-stereotactic targeting of the trigeminal nerve and irradiation with a single 4 mm isocenter, 2-4 mm anterior to the brainstem, could be a safe and effective treatment for this disorder. Materials and Methods: Fifty patients at five centers had radiosurgery using a single 4 mm isocenter targeted at the root entry zone. All patients had typical trigeminal neuralgia. The mean patient age was 70 years, (range, 40-87). Thirty-two patients had undergone prior surgery, and the mean number of procedures performed was 2.8 (range, 1-7). Eighteen patients (36%) had not had prior surgery before radiosurgery. Maximum radiosurgery doses included 60 Gy (n=8), 65 Gy (n=3), 70 Gy (n=27), 75 Gy (n=2), 80 Gy (n=6) and 90 Gy (n=4). All patients were discharged within 24 hours and were studied in regard to the degree of pain relief, latency interval to pain relief, sensory loss, and the need for further therapy. Mean follow-up after radiosurgery was 9.2 months (range, 2-26 months). Results: At last follow-up, 25 patients (50%) had excellent control (pain-free), 17 (34%) had good control (50-90% relief), and 8 (16%) had failed (see Figure). The median time to pain relief was one month. We identified an actuarial response rate of 53% for complete pain relief at seven months, and 93% for pain reduction (50-100% relief). At 18 months, these results declined to 48% and 77% respectively. A significantly greater proportion of patients receiving a radiosurgery maximum dose of {>=} 70 Gy achieved complete pain relief (63% vs. 18%) and >50% pain reduction (96% vs. 80%) than those with doses <70 Gy. Patients without prior surgery had significantly better outcomes in univariate testing. Three patients (6%) developed increased facial paresthesiae after radiosurgery

  14. Therapeutic cranial nerve irradiation: results from a multi-center dose response study of radiosurgery for trigeminal neuralgia

    International Nuclear Information System (INIS)

    Kondziolka, D.; Flickinger, J.; Lunsford, L.D.; Young, R.; Vermeulen, S.; Duma, C.; Jacques, D.B.; Rand, R.; Regis, J.; Peragut, J.C.; Epstein, M.H.; Lindquist, C.

    1995-01-01

    Purpose/Objective: We performed a multi-institution study to evaluate the technique, dose-selection parameters, and results of gamma knife stereotactic radiosurgery in the management of trigeminal neuralgia. We hypothesized that MRI-stereotactic targeting of the trigeminal nerve and irradiation with a single 4 mm isocenter, 2-4 mm anterior to the brainstem, could be a safe and effective treatment for this disorder. Materials and Methods: Fifty patients at five centers had radiosurgery using a single 4 mm isocenter targeted at the root entry zone. All patients had typical trigeminal neuralgia. The mean patient age was 70 years, (range, 40-87). Thirty-two patients had undergone prior surgery, and the mean number of procedures performed was 2.8 (range, 1-7). Eighteen patients (36%) had not had prior surgery before radiosurgery. Maximum radiosurgery doses included 60 Gy (n=8), 65 Gy (n=3), 70 Gy (n=27), 75 Gy (n=2), 80 Gy (n=6) and 90 Gy (n=4). All patients were discharged within 24 hours and were studied in regard to the degree of pain relief, latency interval to pain relief, sensory loss, and the need for further therapy. Mean follow-up after radiosurgery was 9.2 months (range, 2-26 months). Results: At last follow-up, 25 patients (50%) had excellent control (pain-free), 17 (34%) had good control (50-90% relief), and 8 (16%) had failed (see Figure). The median time to pain relief was one month. We identified an actuarial response rate of 53% for complete pain relief at seven months, and 93% for pain reduction (50-100% relief). At 18 months, these results declined to 48% and 77% respectively. A significantly greater proportion of patients receiving a radiosurgery maximum dose of ≥ 70 Gy achieved complete pain relief (63% vs. 18%) and >50% pain reduction (96% vs. 80%) than those with doses <70 Gy. Patients without prior surgery had significantly better outcomes in univariate testing. Three patients (6%) developed increased facial paresthesiae after radiosurgery

  15. Differences in Clinical Results After LINAC-Based Single-Dose Radiosurgery Versus Fractionated Stereotactic Radiotherapy for Patients With Vestibular Schwannomas

    International Nuclear Information System (INIS)

    Combs, Stephanie E.; Welzel, Thomas; Schulz-Ertner, Daniela; Huber, Peter E.; Debus, Juergen

    2010-01-01

    Purpose: To evaluate the outcomes of patients with vestibular schwannoma (VS) treated with fractionated stereotactic radiotherapy (FSRT) vs. those treated with stereotactic radiosurgery (SRS). Methods and Materials: This study is based on an analysis of 200 patients with 202 VSs treated with FSRT (n = 172) or SRS (n = 30). Patients with tumor progression and/or progression of clinical symptoms were selected for treatment. In 165 out of 202 VSs (82%), RT was performed as the primary treatment for VS, and for 37 VSs (18%), RT was conducted for tumor progression after neurosurgical intervention. For patients receiving FSRT, a median total dose of 57.6 Gy was prescribed, with a median fractionation of 5 x 1.8 Gy per week. For patients who underwent SRS, a median single dose of 13 Gy was prescribed to the 80% isodose. Results: FSRT and SRS were well tolerated. Median follow-up time was 75 months. Local control was not statistically different for both groups. The probability of maintaining the pretreatment hearing level after SRS with doses of ≤13 Gy was comparable to that of FSRT. The radiation dose for the SRS group (≤13 Gy vs. >13 Gy) significantly influenced hearing preservation rates (p = 0.03). In the group of patients treated with SRS doses of ≤13 Gy, cranial nerve toxicity was comparable to that of the FSRT group. Conclusions: FSRT and SRS are both safe and effective alternatives for the treatment of VS. Local control rates are comparable in both groups. SRS with doses of ≤13 Gy is a safe alternative to FSRT. While FSRT can be applied safely for the treatment of VSs of all sizes, SRS should be reserved for smaller lesions.

  16. Study of the absorbed dose in small fields with absence of lateral electronic balance in stereotactic radiosurgery and radiotherapy with modulated intensity; Estudio de la dosis absorbida en campos pequenos con ausencia de equilibrio electronico lateral en radiocirugia estereotaxica y radioterapia con intensidad modulada

    Energy Technology Data Exchange (ETDEWEB)

    Vargas V, M. X.

    2013-07-01

    In this thesis we develop and experimental and theoretical study, using semi analytical techniques of the physical dosimetry for small and nonstandard fields for stereotactic radiosurgery (Srs) and intensity modulated radiation therapy (IMRT), with high energy photon beams from a BrainLAB system with cones at Instituto del Cancer SOLCA (Ecuador) and a Tomo Therapy Hi-Art system at Centro Oncologico de Chihuahua (Mexico). (Author)

  17. EGSnrc calculated and MRI-polymer gel dosimeter measured dose distribution of gamma knife in presence of inhomogeneities

    International Nuclear Information System (INIS)

    Allahverdi Pourfallah, T.; Allahverdi, M.; Riahi Alam, N.; Ay, M.; Zahmatkesh, M.; Ibbott, J.S.

    2008-01-01

    Stereotactic gamma-knife radiosurgery plays an important role in managing small intracranial brain lesions. Currently, polymer gel dosimetry is still the only dosimetry method for directly measuring three-dimensional dose distributions. polymer gel dosimeters are tissue equivalent and can act as a phantom material. In this study effects of inhomogeneities on those distributions have been investigated using both EGSnrc calculation and PAGAT polymer gel dosimeter. (author)

  18. Tumour response and morphological changes of acoustic neurinomas after radiosurgery

    International Nuclear Information System (INIS)

    Valentino, V.; Raimondi, A.J.

    1995-01-01

    Twenty-seven of the 1560 patients treated by radiosurgery during the period 1984-1993 had acoustic neurinomas. Four cases were excluded from this study because they had a follow-up of less than 2 years. There were 24 neurinomas treated in 23 patients as one patient had a bilateral tumour. Seven patients underwent radiosurgery for a recurrent tumour (already operated on once or twice), while it was the first treatment for 16 patients. The tumour volume ranged from 1.99 cm 3 to 18.30 cm 3 , and the patient follow-up was from 2 to 8 years. To determine the target on CT/NMR for linear accelerator stereotactic irradiation, the Greitz-Bergstroem non-invasive head fixation device was used. It was again adopted for subsequent serial imaging, and for repeat radiosurgery when necessary. The total peripheral tumour dose ranged from 12 to 45 Gy. In 9 patients there was a reduction in tumour volume varying from 39 to 100% , while 14 of the neurinomas appeared stable after an average follow-up of 3 years. In one patient there was an increase in size of the tumour. Variable morphological changes were present in 66% of the neurinomas treated. Radiosurgery is indicated as an alternative to microsurgery for inoperab1e patients and for those who refuse surgery, for recurrent tumours, and as a post-operative complementary treatment for partially removed tumours. A gradual approach to radiosurgery, depending on tumour response, allows a greater efficacy with minimal risk. In the present series no complications were observed. Hearing was preserved at almost the same level as that prior to radiosurgery in all patients. (author)

  19. The Confluence of Stereotactic Ablative Radiotherapy and Tumor Immunology

    Directory of Open Access Journals (Sweden)

    Steven Eric Finkelstein

    2011-01-01

    Full Text Available Stereotactic radiation approaches are gaining more popularity for the treatment of intracranial as well as extracranial tumors in organs such as the liver and lung. Technology, rather than biology, is driving the rapid adoption of stereotactic body radiation therapy (SBRT, also known as stereotactic ablative radiotherapy (SABR, in the clinic due to advances in precise positioning and targeting. Dramatic improvements in tumor control have been demonstrated; however, our knowledge of normal tissue biology response mechanisms to large fraction sizes is lacking. Herein, we will discuss how SABR can induce cellular expression of MHC I, adhesion molecules, costimulatory molecules, heat shock proteins, inflammatory mediators, immunomodulatory cytokines, and death receptors to enhance antitumor immune responses.

  20. SU-F-T-604: Dosimetric Evaluation of Intracranial Stereotactic Radiotherapy Plans On a LINAC

    Energy Technology Data Exchange (ETDEWEB)

    Sheth, N; Tabibian, A; Rose, J; Alvelo, M; Perel, C; Laiken, K; Kim, A [Bayonne Medical Center, Bayonne, NJ (United States)

    2016-06-15

    Purpose: To evaluate the dosimetry of cranial stereotactic radiotherapy (SRT) plans of varying techniques on linac that meets appropriate TG-142 tolerances using 1 cm leaf width multileaf collimator (MLC). Methods: Seventeen spherical targets were generated in the center of a head phantom with diameters ranging 8 mm to 40 mm. SRT plans used 100° non-coplanar arcs and 5 couch angles with 35° spacing. The field size was target plus 1 mm margin. Four plans were created for each target: symmetrical jaws blocking for 5 arcs with 0° collimator (J1C), symmetrical jaws blocking with 5 clockwise arcs with 0° collimator and 5 counter-clockwise arcs with 45° collimator (J2C), MLC blocking for 5 dynamic conformal arcs with 0° collimator (M1C), and MLC blocking for 5 clockwise dynamic conformal arcs with 0° collimators and 5 counter-clockwise dynamic conformal arcs with 45° collimator (M2C).Conformity was evaluated using a ratio of Rx to target volume (PITV). Heterogeneity was determined using a ratio of maximum dose to Rx dose. Falloff was scored using CGIg: difference of effective radii of spheres equal to half and full Rx volumes. Results: All plans met RTOG SRS criteria for conformity and heterogeneity. The mean PITV was 1.52±0.07, 1.49±0.08, 1.39±0.05, and 1.37±0.04 for J1C, J2C, M1C, and M2C plans respectively. The mean CGIg was 75.35±15.79, 74.19±16.66, 77.14±15.12, and 76.28±15.78 for J1C, J2C, M1C, and M2C plans respectively. The mean MDPD was 1.25±0.00 for all techniques. Conclusion: Clinically acceptable SRT plans for spherical targets were created on a linac with 1 cm MLC. Adding two collimator angles and MLC to arcs each improved conformity. The MLC improved the dose falloff while two collimator angles degraded it. This technique can expand the availability of SRT to patients especially to those who cannot travel to a facility with a dedicated stereotactic radiosurgery machine.

  1. SU-F-T-604: Dosimetric Evaluation of Intracranial Stereotactic Radiotherapy Plans On a LINAC

    International Nuclear Information System (INIS)

    Sheth, N; Tabibian, A; Rose, J; Alvelo, M; Perel, C; Laiken, K; Kim, A

    2016-01-01

    Purpose: To evaluate the dosimetry of cranial stereotactic radiotherapy (SRT) plans of varying techniques on linac that meets appropriate TG-142 tolerances using 1 cm leaf width multileaf collimator (MLC). Methods: Seventeen spherical targets were generated in the center of a head phantom with diameters ranging 8 mm to 40 mm. SRT plans used 100° non-coplanar arcs and 5 couch angles with 35° spacing. The field size was target plus 1 mm margin. Four plans were created for each target: symmetrical jaws blocking for 5 arcs with 0° collimator (J1C), symmetrical jaws blocking with 5 clockwise arcs with 0° collimator and 5 counter-clockwise arcs with 45° collimator (J2C), MLC blocking for 5 dynamic conformal arcs with 0° collimator (M1C), and MLC blocking for 5 clockwise dynamic conformal arcs with 0° collimators and 5 counter-clockwise dynamic conformal arcs with 45° collimator (M2C).Conformity was evaluated using a ratio of Rx to target volume (PITV). Heterogeneity was determined using a ratio of maximum dose to Rx dose. Falloff was scored using CGIg: difference of effective radii of spheres equal to half and full Rx volumes. Results: All plans met RTOG SRS criteria for conformity and heterogeneity. The mean PITV was 1.52±0.07, 1.49±0.08, 1.39±0.05, and 1.37±0.04 for J1C, J2C, M1C, and M2C plans respectively. The mean CGIg was 75.35±15.79, 74.19±16.66, 77.14±15.12, and 76.28±15.78 for J1C, J2C, M1C, and M2C plans respectively. The mean MDPD was 1.25±0.00 for all techniques. Conclusion: Clinically acceptable SRT plans for spherical targets were created on a linac with 1 cm MLC. Adding two collimator angles and MLC to arcs each improved conformity. The MLC improved the dose falloff while two collimator angles degraded it. This technique can expand the availability of SRT to patients especially to those who cannot travel to a facility with a dedicated stereotactic radiosurgery machine.

  2. Calculation of cranial nerve complication probability for acoustic neuroma radiosurgery

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Buatti, John M.; Foote, Kelly D.; Friedman, William A.; Bova, Francis J.

    2000-01-01

    Purpose: Estimations of complications from stereotactic radiosurgery usually rely simply on dose-volume or dose-diameter isoeffect curves. Due to the sparse clinical data available, these curves have typically not considered the target location in the brain, target histology, or treatment plan conformality as parameters in the calculation. In this study, a predictive model was generated to estimate the probability of cranial neuropathies as a result of acoustic schwannoma radiosurgery. Methods and Materials: The dose-volume histogram reduction scheme was used to calculate the normal tissue complication probability (NTCP) from brainstem dose-volume histograms. The model's fitting parameters were optimized to provide the best fit to the observed complication data for acoustic neuroma patients treated with stereotactic radiosurgery at the University of Florida. The calculation was then applied to the remainder of the patients in the database. Results: The best fit to our clinical data was obtained using n = 0.04, m = 0.15, and no. alphano. /no. betano. = 2.1 Gy -1 . Although the fitting parameter m is relatively consistent with ranges found in the literature, both the volume parameter, n, and no. alphano. /no. betano. are much smaller than the values quoted in the literature. The fit to our clinical data indicates that brainstem, or possibly a specific portion of the brainstem, is more radiosensitive than the parameters in the literature indicate, and that there is very little volume effect; in other words, irradiation of a small fraction of the brainstem yields NTCPs that are nearly as high as those calculated for entire volume irradiation. These new fitting parameters are specific to acoustic neuroma radiosurgery, and the small volume effect that we observe may be an artifact of the fixed relationship of acoustic tumors to specific regions of the brainstem. Applying the model to our patient database, we calculate an average NTCP of 7.2% for patients who had no

  3. A dental solution to the reproducible frameless stereotactic problem in fractionated radiosurgery

    International Nuclear Information System (INIS)

    Wasserman, Richard M.; Andres, Eric; Sibata, Claudio; Acharya, Raj; Shin, K.H.

    1996-01-01

    Purpose/Objective: Stereotactic radiosurgery forms an important component of many brain tumor protocols. Patient treatment may be improved when doses are delivered in a fractionated manner over a series of days. Current radiosurgical practices prevent such treatments due to the inaccuracy associated with repeatedly registering pre-treatment imaging scans with the patient's physical location over a discrete series of sessions. We propose a new system for pseudo-frameless stereotactic radio-surgery in which the traditional halo frame system is replaced by a series of dental brackets attached to the upper teeth of each patient. Each bracket may then be fit with sets of fiducial markers which can be localized in the imaging and physical spaces. Patient immobilization will be performed via a custom fit face mask. By decoupling head localization and head immobilization tasks, highly accurate and reproducible fractionated treatment plans may be delivered during a series of treatment sessions. Materials and Methods An experimental custom phantom system was developed in order to evaluate the efficacy of our approach. A rigid head phantom which may be displaced with three rotational degrees of freedom was constructed and fitted with prototype dental brackets. A high contrast CT imaging fixture was then attached to each bracket. The true position of the fixed dental brackets was calculated by direct measurement prior to imaging. Angular encoders were employed to measure the rotational degrees of freedom of the phantom. Multiple imaging scans over a series of series of days were obtained at the Roswell Park Cancer Institute. The high contrast imaging fixtures were removed and replaced prior to each scan in order to best simulate clinical conditions. The origin of each bracket was calculated using analysis software developed at our institution. In order to localize the bracket coordinates in physical space, a specialized probe was constructed with a tip that can interlock with

  4. Dosimetry of cone-defined stereotactic radiosurgery fields with a commercial synthetic diamond detector.

    Science.gov (United States)

    Morales, Johnny E; Crowe, Scott B; Hill, Robin; Freeman, Nigel; Trapp, J V

    2014-11-01

    Small field x-ray beam dosimetry is difficult due to lack of lateral electronic equilibrium, source occlusion, high dose gradients, and detector volume averaging. Currently, there is no single definitive detector recommended for small field dosimetry. The objective of this work was to evaluate the performance of a new commercial synthetic diamond detector, namely, the PTW 60019 microDiamond, for the dosimetry of small x-ray fields as used in stereotactic radiosurgery (SRS). Small field sizes were defined by BrainLAB circular cones (4-30 mm diameter) on a Novalis Trilogy linear accelerator and using the 6 MV SRS x-ray beam mode for all measurements. Percentage depth doses (PDDs) were measured and compared to an IBA SFD and a PTW 60012 E diode. Cross profiles were measured and compared to an IBA SFD diode. Field factors, ΩQclin,Qmsr (fclin,fmsr) , were calculated by Monte Carlo methods using BEAMnrc and correction factors, kQclin,Qmsr (fclin,fmsr) , were derived for the PTW 60019 microDiamond detector. For the small fields of 4-30 mm diameter, there were dose differences in the PDDs of up to 1.5% when compared to an IBA SFD and PTW 60012 E diode detector. For the cross profile measurements the penumbra values varied, depending upon the orientation of the detector. The field factors, ΩQclin,Qmsr (fclin,fmsr) , were calculated for these field diameters at a depth of 1.4 cm in water and they were within 2.7% of published values for a similar linear accelerator. The corrections factors, kQclin,Qmsr (fclin,fmsr) , were derived for the PTW 60019 microDiamond detector. The authors conclude that the new PTW 60019 microDiamond detector is generally suitable for relative dosimetry in small 6 MV SRS beams for a Novalis Trilogy linear equipped with circular cones.

  5. Association Between Radiation Necrosis and Tumor Biology After Stereotactic Radiosurgery for Brain Metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Jacob A. [Cleveland Clinic Lerner College of Medicine, Cleveland Clinic, Cleveland, Ohio (United States); Bennett, Elizabeth E. [Department of Neurological Surgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio (United States); Xiao, Roy [Cleveland Clinic Lerner College of Medicine, Cleveland Clinic, Cleveland, Ohio (United States); Kotecha, Rupesh [Department of Radiation Oncology, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Chao, Samuel T. [Cleveland Clinic Lerner College of Medicine, Cleveland Clinic, Cleveland, Ohio (United States); Department of Radiation Oncology, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Rose Ella Burkhardt Brain Tumor and Neuro-Oncology Center, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Vogelbaum, Michael A.; Barnett, Gene H.; Angelov, Lilyana [Cleveland Clinic Lerner College of Medicine, Cleveland Clinic, Cleveland, Ohio (United States); Department of Neurological Surgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio (United States); Rose Ella Burkhardt Brain Tumor and Neuro-Oncology Center, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Murphy, Erin S.; Yu, Jennifer S. [Cleveland Clinic Lerner College of Medicine, Cleveland Clinic, Cleveland, Ohio (United States); Department of Radiation Oncology, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Rose Ella Burkhardt Brain Tumor and Neuro-Oncology Center, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Ahluwalia, Manmeet S. [Cleveland Clinic Lerner College of Medicine, Cleveland Clinic, Cleveland, Ohio (United States); Rose Ella Burkhardt Brain Tumor and Neuro-Oncology Center, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); and others

    2016-12-01

    Background: The primary dose-limiting toxicity of stereotactic radiosurgery (SRS) is radiation necrosis (RN), which occurs after approximately 5% to 10% of treatments. This adverse event may worsen neurologic deficits, increase the frequency and cost of imaging, and necessitate prolonged treatment with steroids or antiangiogenic agents. Previous investigations have primarily identified lesion size and dosimetric constraints as risk factors for RN in small populations. We hypothesized that disease histology, receptor status, and mutational status are associated with RN. Methods and Materials: All patients presenting with brain metastasis between 1997 and 2015 who underwent SRS and subsequent radiographic follow-up at a single tertiary-care institution were eligible for inclusion. The primary outcome was the cumulative incidence of radiographic RN. Multivariate competing risks regression was used to identify biological risk factors for RN. Results: 1939 patients (5747 lesions) were eligible for inclusion; 285 patients (15%) experienced radiographic RN after the treatment of 427 (7%) lesions. After SRS, the median time to RN was 7.6 months. After multivariate analysis, graded prognostic assessment, renal pathology, lesion diameter, and the heterogeneity index remained independently predictive of RN in the pooled cohort. In subset analyses of individual pathologies, HER2-amplified status (hazard ratio [HR] 2.05, P=.02), BRAF V600+ mutational status (HR 0.33, P=.04), lung adenocarcinoma histology (HR 1.89, P=.04), and ALK rearrangement (HR 6.36, P<.01) were also associated with RN. Conclusions: In the present investigation constituting the largest series of RN, several novel risk factors were identified, including renal histology, lung adenocarcinoma histology, HER2 amplification, and ALK/BRAF mutational status. These risk factors may be used to guide clinical trial design incorporating biological risk stratification or dose escalation. Future studies determining the

  6. Association Between Radiation Necrosis and Tumor Biology After Stereotactic Radiosurgery for Brain Metastasis

    International Nuclear Information System (INIS)

    Miller, Jacob A.; Bennett, Elizabeth E.; Xiao, Roy; Kotecha, Rupesh; Chao, Samuel T.; Vogelbaum, Michael A.; Barnett, Gene H.; Angelov, Lilyana; Murphy, Erin S.; Yu, Jennifer S.; Ahluwalia, Manmeet S.

    2016-01-01

    Background: The primary dose-limiting toxicity of stereotactic radiosurgery (SRS) is radiation necrosis (RN), which occurs after approximately 5% to 10% of treatments. This adverse event may worsen neurologic deficits, increase the frequency and cost of imaging, and necessitate prolonged treatment with steroids or antiangiogenic agents. Previous investigations have primarily identified lesion size and dosimetric constraints as risk factors for RN in small populations. We hypothesized that disease histology, receptor status, and mutational status are associated with RN. Methods and Materials: All patients presenting with brain metastasis between 1997 and 2015 who underwent SRS and subsequent radiographic follow-up at a single tertiary-care institution were eligible for inclusion. The primary outcome was the cumulative incidence of radiographic RN. Multivariate competing risks regression was used to identify biological risk factors for RN. Results: 1939 patients (5747 lesions) were eligible for inclusion; 285 patients (15%) experienced radiographic RN after the treatment of 427 (7%) lesions. After SRS, the median time to RN was 7.6 months. After multivariate analysis, graded prognostic assessment, renal pathology, lesion diameter, and the heterogeneity index remained independently predictive of RN in the pooled cohort. In subset analyses of individual pathologies, HER2-amplified status (hazard ratio [HR] 2.05, P=.02), BRAF V600+ mutational status (HR 0.33, P=.04), lung adenocarcinoma histology (HR 1.89, P=.04), and ALK rearrangement (HR 6.36, P<.01) were also associated with RN. Conclusions: In the present investigation constituting the largest series of RN, several novel risk factors were identified, including renal histology, lung adenocarcinoma histology, HER2 amplification, and ALK/BRAF mutational status. These risk factors may be used to guide clinical trial design incorporating biological risk stratification or dose escalation. Future studies determining the

  7. Phase II study to assess the efficacy of conventionally fractionated radiotherapy followed by a stereotactic radiosurgery boost in patients with locally advanced pancreatic cancer

    International Nuclear Information System (INIS)

    Koong, Albert C.; Christofferson, Erin; Le, Quynh-Thu; Goodman, Karyn A.; Ho, Anthony; Kuo, Timothy; Ford, James M.; Fisher, George A.; Greco, Ralph; Norton, Jeffrey; Yang, George P.

    2005-01-01

    Purpose: To determine the efficacy of concurrent 5-fluorouracil (5-FU) and intensity-modulated radiotherapy (IMRT) followed by body stereotactic radiosurgery (SRS) in patients with locally advanced pancreatic cancer. Methods and Materials: In this prospective study, all patients (19) had pathologically confirmed adenocarcinoma and were uniformly staged. Our treatment protocol consisted of 45 Gy IMRT with concurrent 5-FU followed by a 25 Gy SRS boost to the primary tumor. Results: Sixteen patients completed the planned therapy. Two patients experienced Grade 3 toxicity (none had more than Grade 3 toxicity). Fifteen of these 16 patients were free from local progression until death. Median overall survival was 33 weeks. Conclusions: Concurrent IMRT and 5-FU followed by SRS in patients with locally advanced pancreatic cancer results in excellent local control, but does not improve overall survival and is associated with more toxicity than SRS, alone

  8. Accuracy of marketing claims by providers of stereotactic radiation therapy.

    Science.gov (United States)

    Narang, Amol K; Lam, Edwin; Makary, Martin A; Deweese, Theodore L; Pawlik, Timothy M; Pronovost, Peter J; Herman, Joseph M

    2013-01-01

    Direct-to-consumer advertising by industry has been criticized for encouraging overuse of unproven therapies, but advertising by health care providers has not been as carefully scrutinized. Stereotactic radiation therapy is an emerging technology that has sparked controversy regarding the marketing campaigns of some manufacturers. Given that this technology is also being heavily advertised on the Web sites of health care providers, the accuracy of providers' marketing claims should be rigorously evaluated. We reviewed the Web sites of all U.S. hospitals and private practices that provide stereotactic radiation using two leading brands of stereotactic radiosurgery technology. Centers were identified by using data from the manufacturers. Centers without Web sites were excluded. The final study population consisted of 212 centers with online advertisements for stereotactic radiation. Web sites were evaluated for advertisements that were inconsistent with advertising guidelines provided by the American Medical Association. Most centers (76%) had individual pages dedicated to the marketing of their brand of stereotactic technology that frequently contained manufacturer-authored images (50%) or text (55%). Advertising for the treatment of tumors that have not been endorsed by professional societies was present on 66% of Web sites. Centers commonly claimed improved survival (22%), disease control (20%), quality of life (17%), and toxicity (43%) with stereotactic radiation. Although 40% of Web sites championed the center's regional expertise in delivering stereotactic treatments, only 15% of Web sites provided data to support their claims. Provider advertisements for stereotactic radiation were prominent and aggressive. Further investigation of provider advertising, its effects on quality of care, and potential oversight mechanisms is needed.

  9. The Risk of Radiation-Induced Tumors or Malignant Transformation After Single-Fraction Intracranial Radiosurgery: Results Based on a 25-Year Experience

    Energy Technology Data Exchange (ETDEWEB)

    Pollock, Bruce E., E-mail: pollock.bruce@mayo.edu [Department of Neurological Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota (United States); Department of Radiation Oncology, Mayo Clinic College of Medicine, Rochester, Minnesota (United States); Link, Michael J. [Department of Neurological Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota (United States); Department of Otorhinolaryngology, Mayo Clinic College of Medicine, Rochester, Minnesota (United States); Stafford, Scott L. [Department of Radiation Oncology, Mayo Clinic College of Medicine, Rochester, Minnesota (United States); Parney, Ian F. [Department of Neurological Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota (United States); Garces, Yolanda I.; Foote, Robert L. [Department of Radiation Oncology, Mayo Clinic College of Medicine, Rochester, Minnesota (United States)

    2017-04-01

    Purpose: To determine the risk of radiation-induced tumors or malignant transformation after single-fraction intracranial stereotactic radiosurgery (SRS). Methods and Materials: We performed a retrospective review of 1837 patients who received single-fraction SRS for arteriovenous malformation or benign tumor (meningioma, vestibular schwannoma, pituitary adenoma, glomus tumor) at a single center between 1990 and 2009. Patients were excluded if they refused research authorization (n=31), had a genetic predisposition to tumor development (n=84), received prior or concurrent radiation therapy (n=79), or had less than 5 years of imaging follow-up after SRS (n=501). The median imaging follow-up period for the remaining 1142 patients was 9.0 years (range, 5-24.9 years). Results: No radiation-induced tumors were identified in 11,264 patient-years of follow-up after SRS. The risk of a radiation-induced tumor developing after SRS was 0.0% at 5 years (95% confidence interval [CI], 0.0%-0.4%), 0.0% at 10 years (95% CI, 0.0%-0.9%), and 0.0% at 15 years (95% CI, 0.0%-2.8%). Malignant transformation occurred in 7 of 316 meningioma patients (2.2%) and 1 of 358 vestibular schwannoma patients (0.3%) at a median of 4.9 years (range, 2.8-13.8 years) after SRS. No cases of malignant transformation were noted in patients with pituitary adenomas (n=188) or glomus tumors (n=47). The 5-, 10-, and 15-year risk of malignant transformation was 0.5% (95% CI, 0.0%-0.9%), 0.8% (95% CI, 0.0%-1.8%), and 2.4% (95% CI, 0.0%-5.5%), respectively. Patients who underwent prior resection (hazard ratio, 14.56; 95% CI, 1.79-118.33; P=.01) and who had meningioma pathology (hazard ratio, 11.72; 95% CI, 1.44-96.15; P=.02) were at increased risk of malignant transformation. Conclusions: The risk of radiation-induced tumors or malignant transformation after SRS is very low and should not be used as a justification for choosing alternative treatment approaches (surgical resection, observation) over SRS

  10. The Risk of Radiation-Induced Tumors or Malignant Transformation After Single-Fraction Intracranial Radiosurgery: Results Based on a 25-Year Experience

    International Nuclear Information System (INIS)

    Pollock, Bruce E.; Link, Michael J.; Stafford, Scott L.; Parney, Ian F.; Garces, Yolanda I.; Foote, Robert L.

    2017-01-01

    Purpose: To determine the risk of radiation-induced tumors or malignant transformation after single-fraction intracranial stereotactic radiosurgery (SRS). Methods and Materials: We performed a retrospective review of 1837 patients who received single-fraction SRS for arteriovenous malformation or benign tumor (meningioma, vestibular schwannoma, pituitary adenoma, glomus tumor) at a single center between 1990 and 2009. Patients were excluded if they refused research authorization (n=31), had a genetic predisposition to tumor development (n=84), received prior or concurrent radiation therapy (n=79), or had less than 5 years of imaging follow-up after SRS (n=501). The median imaging follow-up period for the remaining 1142 patients was 9.0 years (range, 5-24.9 years). Results: No radiation-induced tumors were identified in 11,264 patient-years of follow-up after SRS. The risk of a radiation-induced tumor developing after SRS was 0.0% at 5 years (95% confidence interval [CI], 0.0%-0.4%), 0.0% at 10 years (95% CI, 0.0%-0.9%), and 0.0% at 15 years (95% CI, 0.0%-2.8%). Malignant transformation occurred in 7 of 316 meningioma patients (2.2%) and 1 of 358 vestibular schwannoma patients (0.3%) at a median of 4.9 years (range, 2.8-13.8 years) after SRS. No cases of malignant transformation were noted in patients with pituitary adenomas (n=188) or glomus tumors (n=47). The 5-, 10-, and 15-year risk of malignant transformation was 0.5% (95% CI, 0.0%-0.9%), 0.8% (95% CI, 0.0%-1.8%), and 2.4% (95% CI, 0.0%-5.5%), respectively. Patients who underwent prior resection (hazard ratio, 14.56; 95% CI, 1.79-118.33; P=.01) and who had meningioma pathology (hazard ratio, 11.72; 95% CI, 1.44-96.15; P=.02) were at increased risk of malignant transformation. Conclusions: The risk of radiation-induced tumors or malignant transformation after SRS is very low and should not be used as a justification for choosing alternative treatment approaches (surgical resection, observation) over SRS

  11. Analytical calculation of central-axis dosimetric data for a dedicated 6-MV radiosurgery linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Yang, James N.; Pino, Ramiro [Department of Radiation Physics, Unit 94, University of Texas M. D. Anderson Cancer Center, Houston, Texas 77030 (United States); Department of Radiology, Baylor College of Medicine and Methodist Hospital, Houston, Texas 77030 (United States)

    2008-10-15

    Narrow beams are extensively used in stereotactic radiosurgery. The accuracy of treatment planning dose calculation depends largely on how well the dosimetric data are measured during the machine commissioning. Narrow beams are characterized by the lack of lateral electronic equilibrium. The lateral electronic disequilibrium in the radiation field and detector's finite size are likely to compromise the accuracy in dose measurements in these beams. This may have a profound impact on outcome in patients who undergo stereotactic radiosurgery. To confirm the measured commissioning data for a dedicated 6-MV linear accelerator-based radiosurgery system, we developed an analytical model to calculate the narrow photon beam central-axis dose. This model is an extension of a previously reported method of Nizin and Mooij for the calculation of the absorbed dose under lateral electronic disequilibrium conditions at depth of d{sub max} or greater. The scatter factor and tissue-maximum ratio were calculated for narrow beams using the parametrized model and compared to carefully measured results for the same beams. For narrow beam radii ranging from 0.2 to 1.5 cm, the differences between the analytical and measured scatter factors were no greater than 1.4%. In addition, the differences between the analytical and measured tissue-maximum ratios were within 3.3% for regions greater than the maximum dose depth. The estimated error of this analytical calculation was less than 2%, which is sufficient to validate measurement results.

  12. Stereotactic radiation therapy for large vestibular schwannomas

    International Nuclear Information System (INIS)

    Mandl, Ellen S.; Meijer, Otto W.M.; Slotman, Ben J.; Vandertop, W. Peter; Peerdeman, Saskia M.

    2010-01-01

    Background and purpose: To evaluate the morbidity and tumor-control rate in the treatment of large vestibular schwannomas (VS) after stereotactic radiation therapy in our institution. Material and methods: Twenty-five consecutive patients (17 men, 8 women) with large VS (diameter 3.0 cm or larger), treated with stereotactic radiotherapy (SRT) or stereotactic radiosurgery (SRS) between 1992 and 2007, were retrospectively studied after a mean follow-up period of three years with respect to tumor-control rate and complications. Results: Actuarial 5-year maintenance of pre-treatment hearing level probability of 30% was achieved. Five of 17 patients suffered permanent new facial nerve dysfunction. The actuarial 5-year facial nerve preservation probability was 80%. Permanent new trigeminal nerve neuropathy occurred in two of 15 patients, resulting in an actuarial 5-year trigeminal nerve preservation probability of 85%. Tumor progression occurred in four of 25 (16%) patients. The overall 5-year tumor control probability was 82%. Conclusion: Increased morbidity rates were found in patients with large VS treated with SRT or SRS compared to the published series on regular sized VS and other smaller retrospective studies on large VS.

  13. Radiosurgery for metastatic disease at the craniocervical junction.

    Science.gov (United States)

    Tuchman, Alexander; Yu, Cheng; Chang, Eric L; Kim, Paul E; Rusch, Mairead C; Apuzzo, Michael L J

    2014-12-01

    Metastatic disease of the craniovertebral junction (CVJ) can cause pain, cranial nerve deficits, occipitocervical instability, or brainstem/spinal cord compression if left untreated. Many patients with metastasis in this region have a high burden of systemic disease and short life expectancy, making them poor candidates for aggressive surgical resections and fusion procedures. Traditionally, symptom palliation and local disease control in these patients has been achieved through conventional radiation therapy. Stereotactic radiosurgery (SRS) has the advantage of precisely delivering radiation to a target in fewer fractions. To our knowledge, we report the results of the largest series of patients with CVJ metastasis treated with stereotactic radiosurgery. We performed a retrospective review of 9 consecutive patients with 10 tumors of the CVJ treated with SRS at the Keck Medical Center of the University of Southern California. Two tumors were treated with Gamma Knife, whereas the other 8 received CyberKnife. The median marginal dose was 20 Gy (16-24 Gy) over 1-5 fractions. Point maximal dose to the brainstem or spinal cord ranged between 8 and 18.9 Gy. Median survival was 4 months (1-51 months). Five of six patients presenting with pain had at least partial symptom resolution. No patient went on to require surgical decompression or fusion, and there were no complications directly related to SRS. In well-selected patients, SRS for metastatic lesions of the CVJ has a low risk for complications or treatment failure, while achieving a high rate of palliation of pain symptoms. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Extracranial Facial Nerve Schwannoma Treated by Hypo-fractionated CyberKnife Radiosurgery.

    Science.gov (United States)

    Sasaki, Ayaka; Miyazaki, Shinichiro; Hori, Tomokatsu

    2016-09-21

    Facial nerve schwannoma is a rare intracranial tumor. Treatment for this benign tumor has been controversial. Here, we report a case of extracranial facial nerve schwannoma treated successfully by hypo-fractionated CyberKnife (Accuray, Sunnyvale, CA) radiosurgery and discuss the efficacy of this treatment. A 34-year-old female noticed a swelling in her right mastoid process. The lesion enlarged over a seven-month period, and she experienced facial spasm on the right side. She was diagnosed with a facial schwannoma via a magnetic resonance imaging (MRI) scan of the head and neck and was told to wait until the facial nerve palsy subsides. She was referred to our hospital for radiation therapy. We planned a fractionated CyberKnife radiosurgery for three consecutive days. After CyberKnife radiosurgery, the mass in the right parotid gradually decreased in size, and the facial nerve palsy disappeared. At her eight-month follow-up, her facial spasm had completely disappeared. There has been no recurrence and the facial nerve function has been normal. We successfully demonstrated the efficacy of CyberKnife radiosurgery as an alternative treatment that also preserves neurofunction for facial nerve schwannomas.

  15. Single-Fraction Proton Beam Stereotactic Radiosurgery for Cerebral Arteriovenous Malformations

    Energy Technology Data Exchange (ETDEWEB)

    Hattangadi-Gluth, Jona A. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California (United States); Chapman, Paul H. [Department of Neurosurgery, Massachusetts General Hospital, Boston, Massachusetts (United States); Kim, Daniel; Niemierko, Andrzej; Bussière, Marc R.; Stringham, Alison; Daartz, Juliane [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Ogilvy, Christopher [Department of Neurosurgery, Beth Israel Deaconess Medical Center, Boston, Massachusetts (United States); Loeffler, Jay S. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Shih, Helen A., E-mail: hshih@partners.org [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2014-06-01

    Purpose/Objective(s): To evaluate the obliteration rate and potential adverse effects of single-fraction proton beam stereotactic radiosurgery (PSRS) in patients with cerebral arteriovenous malformations (AVMs). Methods and Materials: From 1991 to 2010, 248 consecutive patients with 254 cerebral AVMs received single-fraction PSRS at our institution. The median AVM nidus volume was 3.5 cc (range, 0.1-28.1 cc), 23% of AVMs were in critical/deep locations (basal ganglia, thalamus, or brainstem), and the most common prescription dose was 15 Gy(relative biological effectiveness [RBE]). Univariable and multivariable analyses were performed to assess factors associated with obliteration and hemorrhage. Results: At a median follow-up time of 35 months (range, 6-198 months), 64.6% of AVMs were obliterated. The median time to total obliteration was 31 months (range, 6-127 months), and the 5-year and 10-year cumulative incidence of total obliteration was 70% and 91%, respectively. On univariable analysis, smaller target volume (hazard ratio [HR] 0.78, 95% confidence interval [CI] 0.86-0.93, P<.0001), smaller treatment volume (HR 0.93, 95% CI 0.90-0.96, P<.0001), higher prescription dose (HR 1.16, 95% CI 1.07-1.26, P=.001), and higher maximum dose (HR 1.14, 95% CI 1.05-1.23, P=.002) were associated with total obliteration. Deep/critical location was also associated with decreased likelihood of obliteration (HR 0.68, 95% CI 0.47-0.98, P=.04). On multivariable analysis, critical location (adjusted HR [AHR] 0.42, 95% CI 0.27-0.65, P<.001) and smaller target volume (AHR 0.81, 95% CI 0.68-0.97, P=.02) remained associated with total obliteration. Posttreatment hemorrhage occurred in 13 cases (5-year cumulative incidence of 7%), all among patients with less than total obliteration, and 3 of these events were fatal. The most common complication was seizure, controlled with medications, both acutely (8%) and in the long term (9.1%). Conclusions: The current series is the largest

  16. The neurosurgeon`s perspective; Le point de vue des neurochirurgiens

    Energy Technology Data Exchange (ETDEWEB)

    Lot, G.; Cophignon, J. [Hopital Lariboisiere, 75 - Paris (France)

    1998-03-01

    Stereotactic radiosurgery, a term introduced by Leksell, was born more than 40 years ago, but has made great strides for the last 15 years. There is no consensus among neuro-surgeons as to the best device (gamma knife, linear accelerator), the treatment doses, and the clinical indications of stereotactic radiosurgery. Therefore, this report is the viewpoint of one neurosurgical team only. In the radiosurgery literature, there is no clear evidence of better results with the gamma-knife or the linear accelerators. With regard to clinical applications, cerebral arteriovenous malformations are the more widely accepted indications of radiosurgery, since a cerebral angiography can confirm the disappearance of the nidus of an arteriovenous malformation treated by stereotactic radiosurgery. Usually, small and deep arteriovenous malformations can be treated by stereotactic radiosurgery only. Nevertheless, the treatment of the other arteriovenous malformations more often require procedures including one or several of the following treatment methods: micro-neurosurgery, interventional neuroradiology, stereotactic radiosurgery. Stereotactic radiosurgery in acoustic schwannomas, skull base meningiomas, especially those involving the cavernous sinus, brain metastases, and pituitary tumors seem attractive. Contrary to arteriovenous malformations, the lack of criteria for cure requires a long follow-up and carefully controlled trials to confirm the efficiency of stereotactic radiosurgery for these tumors. On the other hand, experience of stereotactic radiosurgery for astrocytomas and glioblastomas is limited, and few publications are available. Furthermore, because of the infiltrating growth, a major impact of stereotactic radiosurgery for these tumors is presumably not to be expected. Lastly, a close multidisciplinary approach seems absolutely necessary to define the best indications of stereotactic radiosurgery and to improve its clinical results. (authors)

  17. Stereotactic radiosurgery for spinal metastases: a literature review; Radiocirurgia estereotaxica para metastases de coluna vertebral: revisao de literatura

    Energy Technology Data Exchange (ETDEWEB)

    Joaquim, Andrei Fernandes; Ghizoni, Enrico; Tedeschi, Helder; Pereira, Eduardo Baldon; Giacomini, Leonardo Abdala, E-mail: andjoaquim@yahoo.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil)

    2013-04-15

    Objective: The spine is the most common location for bone metastases. Since cure is not possible, local control and relief of symptoms is the basis for treatment, which is grounded on the use of conventional radiotherapy. Recently, spinal radiosurgery has been proposed for the local control of spinal metastases, whether as primary or salvage treatment. Consequently, we carried out a literature review in order to analyze the indications, efficacy, and safety of radiosurgery in the treatment of spinal metastases. Methods: We have reviewed the literature using the PubMed gateway with data from the Medline library on studies related to the use of radiosurgery in treatment of bone metastases in spine. The studies were reviewed by all the authors and classified as to level of evidence, using the criterion defined by Wright. Results: The indications found for radiosurgery were primary control of epidural metastases (evidence level II), myeloma (level III), and metastases known to be poor responders to conventional radiotherapy - melanoma and renal cell carcinoma (level III). Spinal radiosurgery was also proposed for salvage treatment after conventional radiotherapy (level II). There is also some evidence as to the safety and efficacy of radiosurgery in cases of extramedullar and intramedullar intradural metastatic tumors (level III) and after spinal decompression and stabilization surgery. Conclusion: Radiosurgery can be used in primary or salvage treatment of spinal metastases, improving local disease control and patient symptoms. It should also be considered as initial treatment for radioresistant tumors, such as melanoma and renal cell carcinoma. (author)

  18. WE-G-BRD-03: Development of a Real-Time Optical Tracking Goggle System (OTGS) for Intracranial Stereotactic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mittauer, K; Yan, G; Lu, B; Barraclough, B; Li, J; Liu, C [University of Florida, Gainesville, FL (United States)

    2014-06-15

    Purpose: Optical tracking systems (OTS) are an acceptable alternative to frame-based stereotactic radiotherapy (SRT). However, current surface-based OTS lack the ability to target exclusively rigid/bony anatomical features. We propose a novel marker-based optical tracking goggle system (OTGS) that provides real-time guidance based on the nose/facial bony anatomy. This ongoing study involves the development and characterization of the OTGS for clinical implementation in intracranial stereotactic radiotherapy. Methods: The OTGS consists of eye goggles, a custom thermoplastic nosepiece, and 6 infrared markers pre-attached to the goggles. A phantom and four healthy volunteers were used to evaluate the calibration/registration accuracy, intrafraction accuracy, interfraction reproducibility, and end-to-end accuracy of the OTGS. The performance of the OTGS was compared with that of the frameless SonArray system and cone-beam computed tomography (CBCT) for volunteer and phantom cases, respectively. The performance of the OTGS with commercial immobilization devices and under treatment conditions (i.e., couch rotation and translation range) was also evaluated. Results: The difference in the calibration/registration accuracy of 24 translations or rotation combinations between CBCT and in-house OTS software was within 0.5 mm/0.4°. The mean intrafraction and interfraction accuracy among the volunteers was 0.004+/−0.4mm with −0.09+/−0.5° (n=6,170) and −0.26+/−0.8mm with 0.15+/0.8° (n=11), respectively. The difference in end-to-end accuracy between the OTGS and CBCT was within 1.3 mm/1.1°. The predetermined marker pattern (1) minimized marker occlusions, (2) allowed for continuous tracking for couch angles +/− 90°, (3) and eliminated individual marker misplacement. The device was feasible with open and half masks for immobilization. Conclusion: Bony anatomical localization eliminated potential errors due to facial hair changes and/or soft tissue deformation. The

  19. Five-Year Outcomes of High-Dose Single-Fraction Spinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Moussazadeh, Nelson; Lis, Eric; Katsoulakis, Evangelia; Kahn, Sweena; Svoboda, Marek; DiStefano, Natalie M.; McLaughlin, Lily; Bilsky, Mark H.; Yamada, Yoshiya; Laufer, Ilya

    2015-01-01

    Purpose: To characterize local tumor control and toxicity risk in very long-term survivors (>5 years) after high-dose spinal image guided, intensity modulated radiation therapy delivered as single-dose stereotactic radiosurgery (SRS). Previously published spinal SRS outcome analyses have included a heterogeneous population of cancer patients, mostly with short survival. This is the first study reporting the long-term tumor control and toxicity profiles after high-dose single-fraction spinal SRS. Methods and Materials: The study population included all patients treated from June 2004 to July 2009 with single-fraction spinal SRS (dose 24 Gy) who had survived at least 5 years after treatment. The endpoints examined included disease progression, surgical or radiation retreatment, in-field fracture development, and radiation-associated toxicity, scored using the Radiation Therapy Oncology Group radiation morbidity scoring criteria and the Common Terminology Criteria for Adverse Events, version 4.0. Local control and fracture development were assessed using Kaplan-Meier analysis. Results: Of 278 patients, 31 (11.1%), with 36 segments treated for spinal tumors, survived at least 5 years after treatment and were followed up radiographically and clinically for a median of 6.1 years (maximum 102 months). The histopathologic findings for the 5-year survivors included radiation-resistant metastases in 58%, radiation-sensitive metastases in 22%, and primary bone tumors in 19%. In this selected cohort, 3 treatment failures occurred at a median of 48.6 months, including 2 recurrences in the radiation field and 1 patient with demonstrated progression at the treatment margins. Ten lesions (27.8%) were associated with acute grade 1 cutaneous or gastrointestinal toxicity. Delayed toxicity ≥3 months after treatment included 8 cases (22.2%) of mild neuropathy, 2 (5.6%) of gastrointestinal discomfort, 8 (22.2%) of dermatitides, and 3 (8.3%) of myalgias/myositis. Thirteen

  20. Five-Year Outcomes of High-Dose Single-Fraction Spinal Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Moussazadeh, Nelson [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Lis, Eric [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Katsoulakis, Evangelia [Department of Radiation Oncology, New York Methodist Hospital, Brooklyn, New York (United States); Kahn, Sweena; Svoboda, Marek; DiStefano, Natalie M.; McLaughlin, Lily [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Bilsky, Mark H. [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Yamada, Yoshiya [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Laufer, Ilya, E-mail: lauferi@mskcc.org [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States)

    2015-10-01

    Purpose: To characterize local tumor control and toxicity risk in very long-term survivors (>5 years) after high-dose spinal image guided, intensity modulated radiation therapy delivered as single-dose stereotactic radiosurgery (SRS). Previously published spinal SRS outcome analyses have included a heterogeneous population of cancer patients, mostly with short survival. This is the first study reporting the long-term tumor control and toxicity profiles after high-dose single-fraction spinal SRS. Methods and Materials: The study population included all patients treated from June 2004 to July 2009 with single-fraction spinal SRS (dose 24 Gy) who had survived at least 5 years after treatment. The endpoints examined included disease progression, surgical or radiation retreatment, in-field fracture development, and radiation-associated toxicity, scored using the Radiation Therapy Oncology Group radiation morbidity scoring criteria and the Common Terminology Criteria for Adverse Events, version 4.0. Local control and fracture development were assessed using Kaplan-Meier analysis. Results: Of 278 patients, 31 (11.1%), with 36 segments treated for spinal tumors, survived at least 5 years after treatment and were followed up radiographically and clinically for a median of 6.1 years (maximum 102 months). The histopathologic findings for the 5-year survivors included radiation-resistant metastases in 58%, radiation-sensitive metastases in 22%, and primary bone tumors in 19%. In this selected cohort, 3 treatment failures occurred at a median of 48.6 months, including 2 recurrences in the radiation field and 1 patient with demonstrated progression at the treatment margins. Ten lesions (27.8%) were associated with acute grade 1 cutaneous or gastrointestinal toxicity. Delayed toxicity ≥3 months after treatment included 8 cases (22.2%) of mild neuropathy, 2 (5.6%) of gastrointestinal discomfort, 8 (22.2%) of dermatitides, and 3 (8.3%) of myalgias/myositis. Thirteen

  1. Semi-automatic determination of the optimum irradiation parameters in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Boutry, C.; Manens, J.P.; Croci, S.; Scarabin, J.M.

    1995-01-01

    For stereotactic radiosurgery of large lesions or of lesions with irregular shape, the only technique that generates favourable dose distribution is multi-isocentric. The problem is to determine the position of the isocenters that minimize dose heterogeneity within the target volume and maximize the dose gradient outside the target volume. This study was made for two photons energies: γ-rays of Cobalt-60 and 25 MV X-rays. A lead collimator generates circular irradiation beams of diameters 7 to 30 mm at the machine isocenter. By hypothesis, we considered for each isocenter a spherical dose distribution based on an irradiation space defined by sagittal and coronal angular openings of 140 deg. each for 8 equally spaced arcs. The irradiation parameters to be determined are then: the collimator diameter, the number and position of the planes on which the isocenters are placed, and the number and position of the isocenters. We also supposed equidistant isocenters in a linear, triangular, square or complex geometry. The minimum dose point, corresponding to the intersection of the bissectors of the segments joining two consecutive isocenters is inside the geometry. A methodology and rules to determine the irradiation parameters leading to a dose distribution with a reference isodose perfectly adapted to the outlines of the target volume were defined. The collimator diameter is simply correlated to the thickness and the height of the volume to be treated. To determine the number and position of the isocenters we have established simple graphs. These graphs are function of the collimator diameter and the geometric criteria of the volume to be treated (length, thickness, and height). To obtain a dose gradient outside the target volume superior or equal to 5% dose/mm, the collimator diameters must be smaller than or equal to 19 mm for the Cobalt-60 γ-rays and 17 mm for the 25 MV X-rays. For a collimator diameter smaller than or equal to these values, and whatever the photon

  2. Utility and limitation of radiosurgery for metastatic brain tumors

    International Nuclear Information System (INIS)

    Kagawa, Kota; Kiya, Katsuzo; Satoh, Hideki; Mizoue, Tatsuya; Matsushige, Toshinori; Araki, Hayato; Akimitsu, Tomohide

    2003-01-01

    The purpose of this study was to evaluate the utility and limitations of radiosurgery for metastatic brain lesions, and to compare the clinical results of stereotactic radiosurgery (SRS) with those of whole-brain radiation therapy (WBRT) in 45 patients with metastatic brain tumors. The patients were divided into two groups: the SRS group (22 patients) and the WBRT group (23 patients). Mean survival was not significantly different between the two groups. However, in patients with 6 or more lesions, both survival time and recurrence-free time in the SRS group were inferior to those in the WBRT group. The main complication in the SRS group was perifocal edema, while dementia was seen in the WBRT group. The bedridden period was longer in the WBRT group than in the SRS group. Death caused by brain lesions was rare in both groups. From these results, SRS preserves high quality of life longer than WBRT, but SRS should be cautiously used in patients with 6 or more lesions. (author)

  3. Dosimetry of Gamma Knife and linac-based radiosurgery using radiochromic and diode detectors

    International Nuclear Information System (INIS)

    Somigliana, A.; Borelli, S.; Zonca, G.; Pignoli, E.; Loi, G.; Marchesini, R.; Cattaneo, G.M.; Fiorino, C.; Vecchio, A. del; Calandrino, R.

    1999-01-01

    In stereotactic radiosurgery the choice of appropriate detectors, whether for absolute or relative dosimetry, is very important due to the steep dose gradient and the incomplete lateral electronic equilibrium. For both linac-based and Leksell Gamma Knife radiosurgery units, we tested the use of calibrated radiochromic film to measure absolute doses and relative dose distributions. In addition a small diode was used to estimate the relative output factors. The data obtained using radiochromic and diode detectors were compared with measurements performed with other conventional methods of dosimetry, with calculated values by treatment planning systems and with data prestored in the treatment planning system supplied by the Leksell Gamma Knife (LGK) vendor. Two stereotactic radiosurgery techniques were considered: Leksell Gamma Knife (using γ-rays from 60 Co) and linac-based radiosurgery (LR) (6 MV x-rays). Different detectors were used for both relative and absolute dosimetry: relative output factors (OFs) were estimated by using radiochromic and radiographic films and a small diode; relative dose distributions in the axial and coronal planes of a spherical polystyrene phantom were measured using radiochromic film and calculated by two different treatment planning systems (TPSs). The absolute dose at the sphere centre was measured by radiochromic film and a small ionization chamber. An accurate selection of radiochromic film was made: samples of unexposed film showing a percentage standard deviation of less than 3% were used for relative dose profiles, and for absolute dose and OF evaluations this value was reduced to 1.5%. Moreover a proper calibration curve was made for each set of measurements. With regard to absolute doses, the results obtained with the ionization chamber are in good correlation with radiochromic film-generated data, for both LGK and LR, showing a dose difference of less than 1%. The output factor evaluations, performed using different methods

  4. A multi-national report on methods for institutional credentialing for spine radiosurgery

    International Nuclear Information System (INIS)

    Gerszten, Peter C; Shin, John H; Winey, Brian; Oh, Kevin; Sweeney, Reinhart A; Guckenberger, Matthias; Sahgal, Arjun; Sheehan, Jason P; Kersh, Ronald; Chen, Stephanie; Flickinger, John C; Quader, Mubina; Fahim, Daniel; Grills, Inga

    2013-01-01

    Stereotactic body radiotherapy and radiosurgery are rapidly emerging treatment options for both malignant and benign spine tumors. Proper institutional credentialing by physicians and medical physicists as well as other personnel is important for the safe and effective adoption of spine radiosurgery. This article describes the methods for institutional credentialing for spine radiosurgery at seven highly experienced international institutions. All institutions (n = 7) are members of the Elekta Spine Radiosurgery Research Consortium and have a dedicated research and clinical focus on image-guided spine radiosurgery. A questionnaire consisting of 24 items covering various aspects of institutional credentialing for spine radiosurgery was completed by all seven institutions. Close agreement was observed in most aspects of spine radiosurgery credentialing at each institution. A formal credentialing process was believed to be important for the implementation of a new spine radiosurgery program, for patient safety and clinical outcomes. One institution has a written policy specific for spine radiosurgery credentialing, but all have an undocumented credentialing system in place. All institutions rely upon an in-house proctoring system for the training of both physicians and medical physicists. Four institutions require physicians and medical physicists to attend corporate sponsored training. Two of these 4 institutions also require attendance at a non-corporate sponsored academic society radiosurgery course. Corporate as well as non-corporate sponsored training were believed to be complimentary and both important for training. In 5 centers, all cases must be reviewed at a multidisciplinary conference prior to radiosurgery treatment. At 3 centers, neurosurgeons are not required to be involved in all cases if there is no evidence for instability or spinal cord compression. Backup physicians and physicists are required at only 1 institution, but all institutions have more

  5. SU-E-T-128: Applying Failure Modes and Effects Analysis to a Risk-Based Quality Management for Stereotactic Radiosurgery in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, F [comissao nacional de energia nuclear, Rio De Janeiro, RJ (Brazil); Universidade do Estado do Rio de Janeiro, Rio De Janeiro, RJ (Brazil); Almeida, C de [Universidade do Estado do Rio de Janeiro, Rio De Janeiro, RJ (Brazil); Huq, M [University of Pittsburgh Medical Center, Pittsburgh, PA (United States)

    2015-06-15

    Purpose: The goal of the present work was to evaluate the process maps for stereotactic radiosurgery (SRS) treatment at three radiotherapy centers in Brazil and apply the FMEA technique to evaluate similarities and differences, if any, of the hazards and risks associated with these processes. Methods: A team, consisting of professionals from different disciplines and involved in the SRS treatment, was formed at each center. Each team was responsible for the development of the process map, and performance of FMEA and FTA. A facilitator knowledgeable in these techniques led the work at each center. The TG100 recommended scales were used for the evaluation of hazard and severity for each step for the major process “treatment planning”. Results: Hazard index given by the Risk Priority Number (RPN) is found to range from 4–270 for various processes and the severity (S) index is found to range from 1–10. The RPN values > 100 and severity value ≥ 7 were chosen to flag safety improvement interventions. Number of steps with RPN ≥100 were found to be 6, 59 and 45 for the three centers. The corresponding values for S ≥ 7 are 24, 21 and 25 respectively. The range of RPN and S values for each center belong to different process steps and failure modes. Conclusion: These results show that interventions to improve safety is different for each center and it is associated with the skill level of the professional team as well as the technology used to provide radiosurgery treatment. The present study will very likely be a model for implementation of risk-based prospective quality management program for SRS treatment in Brazil where currently there are 28 radiotherapy centers performing SRS. A complete FMEA for SRS for these three radiotherapy centers is currently under development.

  6. SU-E-T-128: Applying Failure Modes and Effects Analysis to a Risk-Based Quality Management for Stereotactic Radiosurgery in Brazil

    International Nuclear Information System (INIS)

    Teixeira, F; Almeida, C de; Huq, M

    2015-01-01

    Purpose: The goal of the present work was to evaluate the process maps for stereotactic radiosurgery (SRS) treatment at three radiotherapy centers in Brazil and apply the FMEA technique to evaluate similarities and differences, if any, of the hazards and risks associated with these processes. Methods: A team, consisting of professionals from different disciplines and involved in the SRS treatment, was formed at each center. Each team was responsible for the development of the process map, and performance of FMEA and FTA. A facilitator knowledgeable in these techniques led the work at each center. The TG100 recommended scales were used for the evaluation of hazard and severity for each step for the major process “treatment planning”. Results: Hazard index given by the Risk Priority Number (RPN) is found to range from 4–270 for various processes and the severity (S) index is found to range from 1–10. The RPN values > 100 and severity value ≥ 7 were chosen to flag safety improvement interventions. Number of steps with RPN ≥100 were found to be 6, 59 and 45 for the three centers. The corresponding values for S ≥ 7 are 24, 21 and 25 respectively. The range of RPN and S values for each center belong to different process steps and failure modes. Conclusion: These results show that interventions to improve safety is different for each center and it is associated with the skill level of the professional team as well as the technology used to provide radiosurgery treatment. The present study will very likely be a model for implementation of risk-based prospective quality management program for SRS treatment in Brazil where currently there are 28 radiotherapy centers performing SRS. A complete FMEA for SRS for these three radiotherapy centers is currently under development

  7. Risk factors for neurological complications after acoustic neurinoma radiosurgery: refinement from further experiences

    International Nuclear Information System (INIS)

    Ito, Ken; Shin, Masahiro; Matsuzaki, Masaki; Sugasawa, Keiko; Sasaki, Tomio

    2000-01-01

    Purpose: Further actuarial analyses of neurological complications were performed on a larger population treated by stereotactic radiosurgery at our institution, to establish the optimal treatment parameters. Methods and Materials: Between June 1990 and September 1998, 138 patients with acoustic neurinomas underwent stereotactic radiosurgery at Tokyo University Hospital. Of these, 125 patients who received medical follow-up for 6 months or more entered the present study. Patient ages ranged from 13 to 77 years (median, 53 years). Average tumor diameter ranged from 6.7 to 25.4 mm (mean, 13.9 mm). Maximum tumor doses ranged from 20 to 40 Gy (mean, 29.8 Gy) and peripheral doses from 12 to 25 Gy (mean, 15.4 Gy). One to 12 isocenters were used (median, 4). Follow-up period ranged from 6 to 104 months (median, 37 months). The potential risk factors for neurological complications were analyzed by two univariate and one multivariate actuarial analyses. Neurological complications examined include hearing loss, facial palsy, and trigeminal nerve dysfunction. Variables included in the analyses were four demographic variables, two variables concerning tumor dimensions, and four variables concerning treatment parameters. A variable with significant p values (p < 0.05) on all three actuarial analyses was considered a risk factor. Results: The variables that had significant correlation to increasing the risk for each neurological complication were: Neurofibromatosis Type 2 (NF2) for both total hearing loss and pure tone threshold (PTA) elevation; history of prior surgical resection, tumor size, and the peripheral tumor dose for facial palsy; and the peripheral tumor dose and gender (being female) for trigeminal neuropathy. In facial palsies caused by radiosurgery, discrepancy between the course of palsy and electrophysiological responses was noted. Conclusion: Risk factors for neurological complications seem to have been almost established, without large differences between

  8. Gamma knife radiosurgery for cerebellopontine angle epidermoid tumors.

    Science.gov (United States)

    El-Shehaby, Amr M N; Reda, Wael A; Abdel Karim, Khaled M; Emad Eldin, Reem M; Nabeel, Ahmed M

    2017-01-01

    Intracranial epidermoid tumors are commonly found in the cerebellopontine angle where they usually present with either trigeminal neuralgia or hemifacial spasm. Radiosurgery for these tumors has rarely been reported. The purpose of this study is to assess the safety and clinical outcome of the treatment of cerebellopontine epidermoid tumors with gamma knife radiosurgery. This is a retrospective study involving 12 patients harboring cerebellopontine angle epidermoid tumors who underwent 15 sessions of gamma knife radiosurgery. Trigeminal pain was present in 8 patients and hemifacial spasm in 3 patients. All cases with trigeminal pain were receiving medication and still uncontrolled. One patient with hemifacial spasm was medically controlled before gamma knife and the other two were not. Two patients had undergone surgical resection prior to gamma knife treatment. The median prescription dose was 11 Gy (10-11 Gy). The tumor volumes ranged from 3.7 to 23.9 cc (median 10.5 cc). The median radiological follow up was 2 years (1-5 years). All tumors were controlled and one tumor shrank. The median clinical follow-up was 5 years. The trigeminal pain improved or disappeared in 5 patients, and of these, 4 cases stopped their medication and one decreased it. The hemifacial spasm resolved in 2 patients who were able to stop their medication. Facial palsy developed in 1 patient and improved with conservative treatment. Transient diplopia was also reported in 2 cases. Gamma knife radiosurgery provides good clinical control for cerebellopontine angle epidermoid tumors.

  9. Post-treatment intracranial hemorrhage of brain metastases from hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Su; Kim, Kyu Bo; Chie, Eui Kyu; Kim, Yoon Jun; Yoon, Jung Hwan; Lee, Hyo Suk; Ha, Sung W. [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2015-03-15

    To evaluate the incidence and risk factors of post-treatment intracranial hemorrhage of brain metastases from hepatocellular carcinoma (HCC). Medical records of 81 patients who have been diagnosed of brain metastases from HCC and underwent surgery, radiosurgery and/or whole brain radiotherapy (WBRT) between January 2000 and December 2013 were retrospectively reviewed. Intracranial hemorrhage was present in 64 patients (79%) at the time of diagnosis. Median value of alpha-fetoprotein (AFP) level was 1,700 ng/mL. The Eastern Cooperative Oncology Group (ECOG) performance status for 20 patients was greater than 2. Fifty-seven patients underwent WBRT and the others were treated with surgery and/or radiosurgery without WBRT. During follow-up, 12 events of intracranial hemorrhage after treatment were identified. Three-month post-treatment hemorrhage rate was 16.1%. Multivariate analyses revealed that ECOG performance status, AFP, and WBRT were associated with post-treatment hemorrhage (p = 0.013, 0.013, and 0.003, respectively). Kaplan-Meier analysis showed that 3-month post-treatment hemorrhage rate of new lesion was higher in patients treated without WBRT, although statistical significance was not reached. (18.6% vs. 4.6%; p = 0.104). Ten of 12 patients with post-treatment hemorrhage died with neurologic cause. WBRT should be considered to prevent post-treatment hemorrhage in the treatment of brain metastases from HCC.

  10. Place of Gamma Knife Stereotactic Radiosurgery in Grade 4 Vestibular Schwannoma Based on Case Series of 86 Patients with Long-Term Follow-Up.

    Science.gov (United States)

    Lefranc, Michel; Da Roz, Leila Maria; Balossier, Anne; Thomassin, Jean Marc; Roche, Pierre Hugue; Regis, Jean

    2018-06-01

    Grade IV vestibular schwannoma (Koos classification) is generally considered to be an indication for microsurgical resection or combined radiosurgery-microsurgery. However, the place of Gamma Knife stereotactic surgery (GK-SRS), either as first-line treatment or when progression of residual tumor compresses the brainstem, has not been clearly evaluated. This article reports the results of a large case series of patients with grade 4 vestibular schwannoma treated by GK-SRS. All consecutive patients with grade IV vestibular schwannoma treated by GK-SRS in our department between 1996 and 2011 with a minimum follow-up of 3 years were included in this study. 86 patients were treated by GK-SRS with a minimum follow-up of 3 years. Mean follow-up was 6.2 years (3-16 years). The mean age of the patients at the time of GK-SRS was 54.6 years (range: 23-84) and the sex ratio was 0.6. At the time of radiosurgery, no patient presented brainstem dysfunction prior to GK-SRS. 38 patients had functional hearing before treatment. One patient presented mild trigeminal neuralgia before GK-SRS. Tumor control with no clinical deterioration was obtained in 78 patients (90.7%). No radiation-induced brainstem or cranial nerve toxicity was observed in any of these patients. Functional hearing was maintained in 25 patients. 8 (9.3%) patients presented tumor growth and required microsurgical resection in 7 cases and ventricular shunt in 1 case. On the basis of this large series, GK-SRS appears to be a safe and effective treatment option for grade IV vestibular schwannoma for patients with no signs of brainstem dysfunction. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. An integrated logistic formula for prediction of complications from radiosurgery

    International Nuclear Information System (INIS)

    Flickinger, J.C.

    1989-01-01

    An integrated logistic model for predicting the probability of complications when small volumes of tissue receive an inhomogeneous radiation dose is described. This model can be used with either an exponential or linear quadratic correction for dose per fraction and time. Both the exponential and linear quadratic versions of this integrated logistic formula provide reasonable estimates of the tolerance of brain to radiosurgical dose distributions where there are small volumes of brain receiving high radiation doses and larger volumes receiving lower doses. This makes it possible to predict the probability of complications from stereotactic radiosurgery, as well as combinations of fractionated large volume irradiation with a radiosurgical boost. Complication probabilities predicted for single fraction radiosurgery with the Leksell Gamma Unit using 4, 8, 14, and 18 mm diameter collimators as well as for whole brain irradiation combined with a radiosurgical boost are presented. The exponential and linear quadratic versions of the integrated logistic formula provide useful methods of calculating the probability of complications from radiosurgical treatment

  12. Practical Implementation of Failure Mode and Effects Analysis for Safety and Efficiency in Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Younge, Kelly Cooper; Wang, Yizhen; Thompson, John; Giovinazzo, Julia; Finlay, Marisa; Sankreacha, Raxa

    2015-01-01

    Purpose: To improve the safety and efficiency of a new stereotactic radiosurgery program with the application of failure mode and effects analysis (FMEA) performed by a multidisciplinary team of health care professionals. Methods and Materials: Representatives included physicists, therapists, dosimetrists, oncologists, and administrators. A detailed process tree was created from an initial high-level process tree to facilitate the identification of possible failure modes. Group members were asked to determine failure modes that they considered to be the highest risk before scoring failure modes. Risk priority numbers (RPNs) were determined by each group member individually and then averaged. Results: A total of 99 failure modes were identified. The 5 failure modes with an RPN above 150 were further analyzed to attempt to reduce these RPNs. Only 1 of the initial items that the group presumed to be high-risk (magnetic resonance imaging laterality reversed) was ranked in these top 5 items. New process controls were put in place to reduce the severity, occurrence, and detectability scores for all of the top 5 failure modes. Conclusions: FMEA is a valuable team activity that can assist in the creation or restructuring of a quality assurance program with the aim of improved safety, quality, and efficiency. Performing the FMEA helped group members to see how they fit into the bigger picture of the program, and it served to reduce biases and preconceived notions about which elements of the program were the riskiest

  13. Practical Implementation of Failure Mode and Effects Analysis for Safety and Efficiency in Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Younge, Kelly Cooper, E-mail: kyounge@med.umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Wang, Yizhen [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Thompson, John; Giovinazzo, Julia; Finlay, Marisa [Department of Radiation Oncology, Trillium Health Partners - Credit Valley Hospital Site, Mississauga Halton/Central West Regional Cancer Program, Mississauga, ON (Canada); Sankreacha, Raxa [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2015-04-01

    Purpose: To improve the safety and efficiency of a new stereotactic radiosurgery program with the application of failure mode and effects analysis (FMEA) performed by a multidisciplinary team of health care professionals. Methods and Materials: Representatives included physicists, therapists, dosimetrists, oncologists, and administrators. A detailed process tree was created from an initial high-level process tree to facilitate the identification of possible failure modes. Group members were asked to determine failure modes that they considered to be the highest risk before scoring failure modes. Risk priority numbers (RPNs) were determined by each group member individually and then averaged. Results: A total of 99 failure modes were identified. The 5 failure modes with an RPN above 150 were further analyzed to attempt to reduce these RPNs. Only 1 of the initial items that the group presumed to be high-risk (magnetic resonance imaging laterality reversed) was ranked in these top 5 items. New process controls were put in place to reduce the severity, occurrence, and detectability scores for all of the top 5 failure modes. Conclusions: FMEA is a valuable team activity that can assist in the creation or restructuring of a quality assurance program with the aim of improved safety, quality, and efficiency. Performing the FMEA helped group members to see how they fit into the bigger picture of the program, and it served to reduce biases and preconceived notions about which elements of the program were the riskiest.

  14. SU-F-T-587: Quality Assurance of Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT) for Patient Specific Plans: A Comparison Between MATRIXX and Delta4 QA Devices

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, YC; Lu, SH; Chen, LH; Kuo, SH; Wang, CW [National Taiwan University Hospital, Taipei City, Taiwan (China)

    2016-06-15

    Purpose: Patient-specific quality assurance (QA) is necessary to accurately deliver high dose radiation to the target, especially for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT). Unlike previous 2 dimensional (D) array QA devices, Delta{sup 4} can verify the dose delivery in 3D. In this study, the difference between calculated and measured dose distribution was compared with two QA devices (MATRIXX and Delta{sup 4}) to evaluate the delivery accuracy. Methods: Twenty-seven SRS/SBRT plans with VMAT were verified with point-dose and dose-map analysis. We use an ion chamber (A1SL, 0.053cc) for point-dose measurement. For verification of the dose map, the differences between the calculated and measured doses were analyzed with a gamma index using MATRIXX and Delta{sup 4} devices. The passing criteria for gamma evaluation were set at 3 mm for distance-to-agreement (DTA) and 3% for dose-difference. A gamma index less than 1 was defined as the verification passing the criteria and satisfying at least 95% of the points. Results: The mean prescribed dose and fraction was 40 ± 14.41 Gy (range: 16–60) and 10 ± 2.35 fractions (range: 1–8), respectively. In point dose analysis, the differences between the calculated and measured doses were all less than 5% (mean: 2.12 ± 1.13%; range: −0.55% to 4.45%). In dose-map analysis, the average passing rates were 99.38 ± 0.96% (range: 95.31–100%) and 100 ± 0.12% (range: 99.5%–100%) for MATRIXX and Delta{sup 4}, respectively. Even using criteria of 2%/2 mm, the passing rate of Delta{sup 4} was still more than 95% (mean: 99 ± 1.08%; range: 95.6%–100%). Conclusion: Both MATRIXX and Delta{sup 4} offer accurate and efficient verification for SRS/SBRT plans. The results measured by MATRIXX and Delta{sup 4} dosimetry systems are similar for SRS/SBRT performed with the VMAT technique.

  15. Analysis of neurological sequelae from radiosurgery of arteriovenous malformations: how location effects outcome

    International Nuclear Information System (INIS)

    Flickinger, John C.; Kondziolka, Douglas; Maitz, Ann H.; Lunsford, L. Dade

    1997-01-01

    Purpose/Objective: To elucidate how the risks of developing temporary and permanent neurological sequelae from radiosurgery for arteriovenous malformations (AVM) relate to AVM location, the addition of stereotactic magnetic resonance (MR) imaging to angiographic targeting, and prior hemorrhage or neurological deficits. Materials and Methods: We evaluated follow-up imaging and clinical data in 332 AVM patients who received gamma knife radiosurgery at the University of Pittsburgh between 1987 and 1994. All patients had regular clinical or imaging follow up for a minimum of two years (range: 24-96 mo., median=45 mo.). 83 patients had MR. planning, and 187 previously bled. Results: Symptomatic post-radiosurgery sequelae (any neurological problem including headache) developed in 30/332 patients (9.0%). Symptoms resolved in 58% of patients within 24 mo. with a significantly greater proportion (p=0.006) resolving in patients with Dmin <20 vs. ≥20 Gy (89 vs. 36%). The 7 yr. actuarial rate for developing persistent symptomatic sequelae was 3.8%. We first evaluated the relative risks for different locations to construct a post-radiosurgery injury expression (PIE) score for AVM location (see Table 1). Multivariate logistic regression analysis of symptomatic post-radiosurgery injury identified independent significant correlations with PIE location score (p=0.0007) and 12 Gy volume (p=0.008) but none of the other factors tested (p≥0.3) including the addition of MR targeting, average radiation dose in 20 cc, prior bleed or neurological deficit. We used these results to construct risk prediction models for any symptomatic post-radiosurgery sequelae and for symptomatic necrosis. Conclusion: The risks of complications from AVM radiosurgery can be predicted according to location with the PIE score and by the 12 Gy treatment volume (Table 2)

  16. The American Society for Therapeutic Radiology and Oncology (ASTRO) evidence-based review of the role of radiosurgery for brain metastases

    International Nuclear Information System (INIS)

    Mehta, Minesh P.; Tsao, May N.; Whelan, Timothy J.; Morris, David E.; Hayman, James A.; Flickinger, John C.; Mills, Michael; Rogers, C. Leland; Souhami, Luis

    2005-01-01

    Purpose: To systematically review the evidence for the use of stereotactic radiosurgery in adult patients with brain metastases. Methods: Key clinical questions to be addressed in this evidence-based review were identified. Outcomes considered were overall survival, quality of life or symptom control, brain tumor control or response and toxicity. MEDLINE (1990-2004 June Week 2), CANCERLIT (1990-2003), CINAHL (1990-2004 June Week 2), EMBASE (1990-2004 Week 25), and the Cochrane library (2004 issue 2) databases were searched using OVID. In addition, the Physician Data Query clinical trials database, the proceedings of the American Society of Clinical Oncology (ASCO) (1997-2004), ASTRO (1997-2004), and the European Society of Therapeutic Radiology and Oncology (ESTRO) (1997-2003) were searched. Data from the literature search were reviewed and tabulated. This process included an assessment of the level of evidence. Results: For patients with newly diagnosed brain metastases, managed with whole-brain radiotherapy alone vs. whole-brain radiotherapy and radiosurgery boost, there were three randomized controlled trials, zero prospective studies, and seven retrospective series (which satisfied inclusion criteria). For patients with up to three (<4 cm) newly diagnosed brain metastases (and in one study up to four brain metastases), radiosurgery boost with whole-brain radiotherapy significantly improves local brain control rates as compared with whole-brain radiotherapy alone (Level I-III evidence). In one large randomized trial, survival benefit with whole-brain radiotherapy was observed in patients with single brain metastasis. In this trial, an overall increased ability to taper down on steroid dose and an improvement in Karnofsky performance status was seen in patients who were treated with radiosurgery boost as compared with patients treated with whole-brain radiotherapy alone. However, Level I evidence regarding overall quality of life outcomes using a validated

  17. Analysis of the Factors Contributing to Vertebral Compression Fractures After Spine Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Boyce-Fappiano, David; Elibe, Erinma [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan (United States); Schultz, Lonni [Department of Neurosurgery, Henry Ford Health System, Detroit, Michigan (United States); Ryu, Samuel [Department of Radiation Oncology, Stony Brook University School of Medicine, Stony Brook, New York (United States); Siddiqui, M. Salim; Chetty, Indrin [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan (United States); Lee, Ian; Rock, Jack [Department of Neurosurgery, Henry Ford Health System, Detroit, Michigan (United States); Movsas, Benjamin [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan (United States); Siddiqui, Farzan, E-mail: fsiddiq2@hfhs.org [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan (United States)

    2017-02-01

    Purpose: To determine our institutional vertebral compression fracture (VCF) rate after spine stereotactic radiosurgery (SRS) and determine contributory factors. Methods and Materials: Retrospective analysis from 2001 to 2013 at a single institution was performed. With institutional review board approval, electronic medical records of 1905 vertebral bodies from 791 patients who were treated with SRS for the management of primary or metastatic spinal lesions were reviewed. A total of 448 patients (1070 vertebral bodies) with adequate follow-up imaging studies available were analyzed. Doses ranging from 10 Gy in 1 fraction to 60 Gy in 5 fractions were delivered. Computed tomography and magnetic resonance imaging were used to evaluate the primary endpoints of this study: development of a new VCF, progression of an existing VCF, and requirement of stabilization surgery after SRS. Results: A total of 127 VCFs (11.9%; 95% confidence interval [CI] 9.5%-14.2%) in 97 patients were potentially SRS induced: 46 (36%) were de novo, 44 (35%) VCFs progressed, and 37 (29%) required stabilization surgery after SRS. Our rate for radiologic VCF development/progression (excluding patients who underwent surgery) was 8.4%. Upon further exclusion of patients with hematologic malignancies the VCF rate was 7.6%. In the univariate analyses, females (hazard ratio [HR] 1.54, 95% CI 1.01-2.33, P=.04), prior VCF (HR 1.99, 95% CI 1.30-3.06, P=.001), primary hematologic malignancies (HR 2.68, 95% CI 1.68-4.28, P<.001), thoracic spine lesions (HR 1.46, 95% CI 1.02-2.10, P=.02), and lytic lesions had a significantly increased risk for VCF after SRS. On multivariate analyses, prior VCF and lesion type remained contributory. Conclusions: Single-fraction SRS doses of 16 to 18 Gy to the spine seem to be associated with a low rate of VCFs. To the best of our knowledge, this is the largest reported experience analyzing SRS-induced VCFs, with one of the lowest event rates reported.

  18. Analysis of the Factors Contributing to Vertebral Compression Fractures After Spine Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Boyce-Fappiano, David; Elibe, Erinma; Schultz, Lonni; Ryu, Samuel; Siddiqui, M. Salim; Chetty, Indrin; Lee, Ian; Rock, Jack; Movsas, Benjamin; Siddiqui, Farzan

    2017-01-01

    Purpose: To determine our institutional vertebral compression fracture (VCF) rate after spine stereotactic radiosurgery (SRS) and determine contributory factors. Methods and Materials: Retrospective analysis from 2001 to 2013 at a single institution was performed. With institutional review board approval, electronic medical records of 1905 vertebral bodies from 791 patients who were treated with SRS for the management of primary or metastatic spinal lesions were reviewed. A total of 448 patients (1070 vertebral bodies) with adequate follow-up imaging studies available were analyzed. Doses ranging from 10 Gy in 1 fraction to 60 Gy in 5 fractions were delivered. Computed tomography and magnetic resonance imaging were used to evaluate the primary endpoints of this study: development of a new VCF, progression of an existing VCF, and requirement of stabilization surgery after SRS. Results: A total of 127 VCFs (11.9%; 95% confidence interval [CI] 9.5%-14.2%) in 97 patients were potentially SRS induced: 46 (36%) were de novo, 44 (35%) VCFs progressed, and 37 (29%) required stabilization surgery after SRS. Our rate for radiologic VCF development/progression (excluding patients who underwent surgery) was 8.4%. Upon further exclusion of patients with hematologic malignancies the VCF rate was 7.6%. In the univariate analyses, females (hazard ratio [HR] 1.54, 95% CI 1.01-2.33, P=.04), prior VCF (HR 1.99, 95% CI 1.30-3.06, P=.001), primary hematologic malignancies (HR 2.68, 95% CI 1.68-4.28, P<.001), thoracic spine lesions (HR 1.46, 95% CI 1.02-2.10, P=.02), and lytic lesions had a significantly increased risk for VCF after SRS. On multivariate analyses, prior VCF and lesion type remained contributory. Conclusions: Single-fraction SRS doses of 16 to 18 Gy to the spine seem to be associated with a low rate of VCFs. To the best of our knowledge, this is the largest reported experience analyzing SRS-induced VCFs, with one of the lowest event rates reported.

  19. TU-A-BRB-02: Panel Member

    International Nuclear Information System (INIS)

    Ma, L.

    2016-01-01

    Brain stereotactic radiosurgery (SRS) and spine stereotactic body radiation therapy (SBRT) are commonly treated by a multidisciplinary team of neurosurgeons, radiation oncologists, and medical physicists. However the treatment objectives, constraints, and technical considerations involved can be quite different between the two techniques. In this interactive session an expert panel of speakers will present clinical brain SRS and spine SBRT cases in order to demonstrate real-world considerations for ensuring safe and accurate treatment delivery and to highlight the significant differences in approach for each treatment site. The session will include discussion of topic such as clinical indications, immobilization, target definition, normal tissue tolerance limits, and beam arrangements. Learning Objectives: Understand the differences in indications and dose/fractionation strategies for intracranial SRS and spine SBRT. Describe the different treatment modalities which can be used to deliver intracranial SRS and spine SBRT. Cite the major differences in treatment setup and delivery principles between intracranial and spine treatments. Identify key critical structures and clinical dosimetric tolerance levels for spine SBRT and intracranial SRS. Understand areas of ongoing work to standardize intracranial SRS and spine SBRT procedures. Schlesinger: Research support: Elekta Instruments, AB; D. Schlesinger, Elekta Instruments, AB - research support; B. Winey, No relevant external funding for this subject.

  20. TU-A-BRB-03: Panel Member

    International Nuclear Information System (INIS)

    Winey, B.

    2016-01-01

    Brain stereotactic radiosurgery (SRS) and spine stereotactic body radiation therapy (SBRT) are commonly treated by a multidisciplinary team of neurosurgeons, radiation oncologists, and medical physicists. However the treatment objectives, constraints, and technical considerations involved can be quite different between the two techniques. In this interactive session an expert panel of speakers will present clinical brain SRS and spine SBRT cases in order to demonstrate real-world considerations for ensuring safe and accurate treatment delivery and to highlight the significant differences in approach for each treatment site. The session will include discussion of topic such as clinical indications, immobilization, target definition, normal tissue tolerance limits, and beam arrangements. Learning Objectives: Understand the differences in indications and dose/fractionation strategies for intracranial SRS and spine SBRT. Describe the different treatment modalities which can be used to deliver intracranial SRS and spine SBRT. Cite the major differences in treatment setup and delivery principles between intracranial and spine treatments. Identify key critical structures and clinical dosimetric tolerance levels for spine SBRT and intracranial SRS. Understand areas of ongoing work to standardize intracranial SRS and spine SBRT procedures. Schlesinger: Research support: Elekta Instruments, AB; D. Schlesinger, Elekta Instruments, AB - research support; B. Winey, No relevant external funding for this subject.

  1. TU-A-BRB-02: Panel Member

    Energy Technology Data Exchange (ETDEWEB)

    Ma, L. [UCSF Comprehensive Cancer Center (United States)

    2016-06-15

    Brain stereotactic radiosurgery (SRS) and spine stereotactic body radiation therapy (SBRT) are commonly treated by a multidisciplinary team of neurosurgeons, radiation oncologists, and medical physicists. However the treatment objectives, constraints, and technical considerations involved can be quite different between the two techniques. In this interactive session an expert panel of speakers will present clinical brain SRS and spine SBRT cases in order to demonstrate real-world considerations for ensuring safe and accurate treatment delivery and to highlight the significant differences in approach for each treatment site. The session will include discussion of topic such as clinical indications, immobilization, target definition, normal tissue tolerance limits, and beam arrangements. Learning Objectives: Understand the differences in indications and dose/fractionation strategies for intracranial SRS and spine SBRT. Describe the different treatment modalities which can be used to deliver intracranial SRS and spine SBRT. Cite the major differences in treatment setup and delivery principles between intracranial and spine treatments. Identify key critical structures and clinical dosimetric tolerance levels for spine SBRT and intracranial SRS. Understand areas of ongoing work to standardize intracranial SRS and spine SBRT procedures. Schlesinger: Research support: Elekta Instruments, AB; D. Schlesinger, Elekta Instruments, AB - research support; B. Winey, No relevant external funding for this subject.

  2. TU-A-BRB-00: PANEL DISCUSSION: SBRT/SRS Case Studies - Brain and Spine

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Brain stereotactic radiosurgery (SRS) and spine stereotactic body radiation therapy (SBRT) are commonly treated by a multidisciplinary team of neurosurgeons, radiation oncologists, and medical physicists. However the treatment objectives, constraints, and technical considerations involved can be quite different between the two techniques. In this interactive session an expert panel of speakers will present clinical brain SRS and spine SBRT cases in order to demonstrate real-world considerations for ensuring safe and accurate treatment delivery and to highlight the significant differences in approach for each treatment site. The session will include discussion of topic such as clinical indications, immobilization, target definition, normal tissue tolerance limits, and beam arrangements. Learning Objectives: Understand the differences in indications and dose/fractionation strategies for intracranial SRS and spine SBRT. Describe the different treatment modalities which can be used to deliver intracranial SRS and spine SBRT. Cite the major differences in treatment setup and delivery principles between intracranial and spine treatments. Identify key critical structures and clinical dosimetric tolerance levels for spine SBRT and intracranial SRS. Understand areas of ongoing work to standardize intracranial SRS and spine SBRT procedures. Schlesinger: Research support: Elekta Instruments, AB; D. Schlesinger, Elekta Instruments, AB - research support; B. Winey, No relevant external funding for this subject.

  3. TU-A-BRB-03: Panel Member

    Energy Technology Data Exchange (ETDEWEB)

    Winey, B. [Massachusetts General Hospital (United States)

    2016-06-15

    Brain stereotactic radiosurgery (SRS) and spine stereotactic body radiation therapy (SBRT) are commonly treated by a multidisciplinary team of neurosurgeons, radiation oncologists, and medical physicists. However the treatment objectives, constraints, and technical considerations involved can be quite different between the two techniques. In this interactive session an expert panel of speakers will present clinical brain SRS and spine SBRT cases in order to demonstrate real-world considerations for ensuring safe and accurate treatment delivery and to highlight the significant differences in approach for each treatment site. The session will include discussion of topic such as clinical indications, immobilization, target definition, normal tissue tolerance limits, and beam arrangements. Learning Objectives: Understand the differences in indications and dose/fractionation strategies for intracranial SRS and spine SBRT. Describe the different treatment modalities which can be used to deliver intracranial SRS and spine SBRT. Cite the major differences in treatment setup and delivery principles between intracranial and spine treatments. Identify key critical structures and clinical dosimetric tolerance levels for spine SBRT and intracranial SRS. Understand areas of ongoing work to standardize intracranial SRS and spine SBRT procedures. Schlesinger: Research support: Elekta Instruments, AB; D. Schlesinger, Elekta Instruments, AB - research support; B. Winey, No relevant external funding for this subject.

  4. TU-A-BRB-01: Panel Member

    Energy Technology Data Exchange (ETDEWEB)

    Schlesinger, D. [University of Virginia Health Systems (United States)

    2016-06-15

    Brain stereotactic radiosurgery (SRS) and spine stereotactic body radiation therapy (SBRT) are commonly treated by a multidisciplinary team of neurosurgeons, radiation oncologists, and medical physicists. However the treatment objectives, constraints, and technical considerations involved can be quite different between the two techniques. In this interactive session an expert panel of speakers will present clinical brain SRS and spine SBRT cases in order to demonstrate real-world considerations for ensuring safe and accurate treatment delivery and to highlight the significant differences in approach for each treatment site. The session will include discussion of topic such as clinical indications, immobilization, target definition, normal tissue tolerance limits, and beam arrangements. Learning Objectives: Understand the differences in indications and dose/fractionation strategies for intracranial SRS and spine SBRT. Describe the different treatment modalities which can be used to deliver intracranial SRS and spine SBRT. Cite the major differences in treatment setup and delivery principles between intracranial and spine treatments. Identify key critical structures and clinical dosimetric tolerance levels for spine SBRT and intracranial SRS. Understand areas of ongoing work to standardize intracranial SRS and spine SBRT procedures. Schlesinger: Research support: Elekta Instruments, AB; D. Schlesinger, Elekta Instruments, AB - research support; B. Winey, No relevant external funding for this subject.

  5. TU-A-BRB-01: Panel Member

    International Nuclear Information System (INIS)

    Schlesinger, D.

    2016-01-01

    Brain stereotactic radiosurgery (SRS) and spine stereotactic body radiation therapy (SBRT) are commonly treated by a multidisciplinary team of neurosurgeons, radiation oncologists, and medical physicists. However the treatment objectives, constraints, and technical considerations involved can be quite different between the two techniques. In this interactive session an expert panel of speakers will present clinical brain SRS and spine SBRT cases in order to demonstrate real-world considerations for ensuring safe and accurate treatment delivery and to highlight the significant differences in approach for each treatment site. The session will include discussion of topic such as clinical indications, immobilization, target definition, normal tissue tolerance limits, and beam arrangements. Learning Objectives: Understand the differences in indications and dose/fractionation strategies for intracranial SRS and spine SBRT. Describe the different treatment modalities which can be used to deliver intracranial SRS and spine SBRT. Cite the major differences in treatment setup and delivery principles between intracranial and spine treatments. Identify key critical structures and clinical dosimetric tolerance levels for spine SBRT and intracranial SRS. Understand areas of ongoing work to standardize intracranial SRS and spine SBRT procedures. Schlesinger: Research support: Elekta Instruments, AB; D. Schlesinger, Elekta Instruments, AB - research support; B. Winey, No relevant external funding for this subject.

  6. TU-A-BRB-00: PANEL DISCUSSION: SBRT/SRS Case Studies - Brain and Spine

    International Nuclear Information System (INIS)

    2016-01-01

    Brain stereotactic radiosurgery (SRS) and spine stereotactic body radiation therapy (SBRT) are commonly treated by a multidisciplinary team of neurosurgeons, radiation oncologists, and medical physicists. However the treatment objectives, constraints, and technical considerations involved can be quite different between the two techniques. In this interactive session an expert panel of speakers will present clinical brain SRS and spine SBRT cases in order to demonstrate real-world considerations for ensuring safe and accurate treatment delivery and to highlight the significant differences in approach for each treatment site. The session will include discussion of topic such as clinical indications, immobilization, target definition, normal tissue tolerance limits, and beam arrangements. Learning Objectives: Understand the differences in indications and dose/fractionation strategies for intracranial SRS and spine SBRT. Describe the different treatment modalities which can be used to deliver intracranial SRS and spine SBRT. Cite the major differences in treatment setup and delivery principles between intracranial and spine treatments. Identify key critical structures and clinical dosimetric tolerance levels for spine SBRT and intracranial SRS. Understand areas of ongoing work to standardize intracranial SRS and spine SBRT procedures. Schlesinger: Research support: Elekta Instruments, AB; D. Schlesinger, Elekta Instruments, AB - research support; B. Winey, No relevant external funding for this subject.

  7. Improved results for vestibular schwannoma radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Flickinger, J C; Kondziolka, D; Pollock, B; Lunsford, L D

    1995-07-01

    PURPOSE/OBJECTIVE: Treatment techniques in radiosurgery have changed since 1987. We reviewed patients who received radiosurgery for vestibular schwannoma to identify these changes and to investigate any differences in tumor control and complications. MATERIALS and METHODS: One hundred thirty-eight unilateral vestibular schwannoma patients with a minimum follow-up of two years after treatment with gamma knife radiosurgery between 1987 and 1992 were analyzed. The early treatment group consisted of 55 patients treated between 1987-1989 (median: tumor volume 3.63 cc, Dmin 18.1 Gy, Dmax 35.4 Gy, isocenters 2.3, follow-up 50.4 mos.). The later treatment group consisted of 83 patients treated between 1990-1992 (median: tumor volume 3.81 cc, Dmin 16.0 Gy, Dmax 31.6 Gy, isocenters 4.7, follow-up 35.8 mos.) RESULTS: Clinical tumor recurrence requiring surgical intervention occurred in one patient in each group. The overall actuarial clinical tumor control rate was 98%. Slight increases in tumor size (1 to 2 mm) were identified in five other patients not requiring intervention, because of no further tumor growth (n=4) or shrinkage (n=1). This led to an overall radiologic tumor control rate of 92% (not significantly different in either group). Compared to the early treatment group, the incidence of facial neuropathy (temporary or permanent) decreased in the later group (49% vs. 11%, p < 0.0001), as did trigeminal neuropathy (40% vs. 8%, p < 0.0001). Serviceable hearing preservation improved only slightly in the later group (27% vs. 40%, p = 0.70). CONCLUSION: We document a significant decrease in the morbidity of vestibular schwannoma radiosurgery over this time period with no decrease in the high rate of tumor control. This improvement is attributed to a) better conformal dose-planning with stereotactic MRI rather than CT, b) an increase in the number of isocenters used, and c) a reduction in the average dose administered by 2 Gy.

  8. SU-C-BRA-06: Automatic Brain Tumor Segmentation for Stereotactic Radiosurgery Applications

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y; Stojadinovic, S; Jiang, S; Timmerman, R; Abdulrahman, R; Nedzi, L; Gu, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: Stereotactic radiosurgery (SRS), which delivers a potent dose of highly conformal radiation to the target in a single fraction, requires accurate tumor delineation for treatment planning. We present an automatic segmentation strategy, that synergizes intensity histogram thresholding, super-voxel clustering, and level-set based contour evolving methods to efficiently and accurately delineate SRS brain tumors on contrast-enhance T1-weighted (T1c) Magnetic Resonance Images (MRI). Methods: The developed auto-segmentation strategy consists of three major steps. Firstly, tumor sites are localized through 2D slice intensity histogram scanning. Then, super voxels are obtained through clustering the corresponding voxels in 3D with reference to the similarity metrics composited from spatial distance and intensity difference. The combination of the above two could generate the initial contour surface. Finally, a localized region active contour model is utilized to evolve the surface to achieve the accurate delineation of the tumors. The developed method was evaluated on numerical phantom data, synthetic BRATS (Multimodal Brain Tumor Image Segmentation challenge) data, and clinical patients’ data. The auto-segmentation results were quantitatively evaluated by comparing to ground truths with both volume and surface similarity metrics. Results: DICE coefficient (DC) was performed as a quantitative metric to evaluate the auto-segmentation in the numerical phantom with 8 tumors. DCs are 0.999±0.001 without noise, 0.969±0.065 with Rician noise and 0.976±0.038 with Gaussian noise. DC, NMI (Normalized Mutual Information), SSIM (Structural Similarity) and Hausdorff distance (HD) were calculated as the metrics for the BRATS and patients’ data. Assessment of BRATS data across 25 tumor segmentation yield DC 0.886±0.078, NMI 0.817±0.108, SSIM 0.997±0.002, and HD 6.483±4.079mm. Evaluation on 8 patients with total 14 tumor sites yield DC 0.872±0.070, NMI 0.824±0

  9. Radiosurgery of pituitary adenomas

    International Nuclear Information System (INIS)

    Kida, Yoshihisa

    2008-01-01

    The efficacy and role of gamma knife (GK) in the treatment of various pituitary adenomas are described on author's experience and discussed with literature. GK subjects are 328 patients (M 126/F 202, av. age of 47.8 y) in author's hospital, and satisfactory follow-up (32-44 mo) for evaluation has been possible in 253 cases, who had tumors non-functional (129 cases), producing ACTH (23), HGH (70) and PRL (31). Stereotactic GK radiosurgery is done with navigation by Gamma Plan based on enhanced MRI images at various doses, and evaluation in the follow-up period is performed by hormonal levels and MRI which give efficacy of complete response (CR), partial response (PR), MR and standard deviation (SD)/ progressive disease (PD) on the tumor size. The overall tumor control rate is found to be 95-100%. Effectiveness (CR and PR) is found as high as 77.4% in PRL-producing tumor (marginal dose 14-32 Gy), 65% in non-functioning (15-25 Gy), 61% in ACTH (19-30 Gy) and 60% in GH (19-31 Gy), of which tendency is similar to that in literature. Even in ACTH-producing tumor, low ACTH and cortisol levels persisted with tendency of improved obese and hypertensive symptoms. GK radiosurgery has limitations in the tissue size and distance between the tumor and optic nerve/chiasm, but for the enough small tumor, it gives satisfactorily long term efficacy. (R.T.)

  10. Pain relief by Cyberknife radiosurgery for spinal metastasis.

    Science.gov (United States)

    Lee, Sunyoung; Chun, Mison

    2012-01-01

    To report pain relief effect in patients with spinal metastases treated with Cyberknife® and to analyze the factors associated with pain relapse after initial pain relief. We retrospectively analyzed patients with spinal metastasis treated with stereotactic body radiosurgery between April 2007 and June 2009. A total of 57 patients with 73 lesions were available for analysis with a median follow-up of 6.8 months (range, 1-30). Pain was assessed by a verbal/visual analogue scale at each visit: from 0 to 10. Pain relief was defined as a decrease of at least three levels of the pain score without an increase in analgesic use. Complete relief was defined as no analgesics or a score 0 or 1. Pain relief was achieved in 88% of the lesions, with complete relief in 51% within 7 days from the start of radiosurgery. The median duration of pain relief was 3.2 months (range, 1-30). Pain reappeared in 16 patients (27%). Spinal cord compression (P = 0.001) and performance status (P = 0.01) were predictive of pain relapse by multivariate Cox analysis. All 6 patients treated with solitary spinal metastasis experienced pain relief; 5 of them were alive without evidence of disease at a median of 16 months (range, 7-30). As previous studies have shown, our study confirms that pain relief with spinal radiosurgery is around 90%. In particular, long-term pain relief and disease control was observed in patients with solitary spinal metastasis.

  11. The use of stereotactic radiosurgical boost in the treatment of medulloblastomas

    International Nuclear Information System (INIS)

    Woo, Charles; Stea, Baldassarre; Lulu, Bruce; Hamilton, Allan; Cassady, J. Robert

    1997-01-01

    Purpose: Starting in 1992, we began using a stereotactic radiosurgical (SRS) boost for the treatment of medulloblastomas. Four patients ranging in age from 7 to 42 years old have since been treated and are the subject of this retrospective study. Methods and Materials: All patients were initially treated with a maximally debulking surgery and external beam radiotherapy, which were then followed by a stereotactic radiosurgical boost using a modified 6 MeV linear accelerator. Radiosurgical boost doses ranged from 4.50 to 10.0 Gy. Target volumes ranged from 1.1 to 8.1 cc. The procedure was well tolerated with minimal acute toxicities. Results: All four patients are alive without evidence of recurrence (at 8 to 35 months). Acute nausea and vomiting was elicited during the radiosurgical procedure in the first patient treated. We have since begun premedicating patients with antiemetics or treating under general anesthesia. Late complications consisted of panhypopituitarism in one patient, which was thought to be attributable to the previous course of whole-brain radiotherapy. We have not observed any incidence of radionecrosis in this small cohort of patients. Conclusions: Our preliminary results with the use of radiosurgery for medulloblastomas are optimistic, and we would like to suggest the inclusion of a radiosurgery boost in future clinical trials for treatment of this disease

  12. Design and implementation of a 3D-MR/CT geometric image distortion phantom/analysis system for stereotactic radiosurgery

    Science.gov (United States)

    Damyanovich, A. Z.; Rieker, M.; Zhang, B.; Bissonnette, J.-P.; Jaffray, D. A.

    2018-04-01

    The design, construction and application of a multimodality, 3D magnetic resonance/computed tomography (MR/CT) image distortion phantom and analysis system for stereotactic radiosurgery (SRS) is presented. The phantom is characterized by (1) a 1 × 1 × 1 (cm)3 MRI/CT-visible 3D-Cartesian grid; (2) 2002 grid vertices that are 3D-intersections of MR-/CT-visible ‘lines’ in all three orthogonal planes; (3) a 3D-grid that is MR-signal positive/CT-signal negative; (4) a vertex distribution sufficiently ‘dense’ to characterize geometrical parameters properly, and (5) a grid/vertex resolution consistent with SRS localization accuracy. When positioned correctly, successive 3D-vertex planes along any orthogonal axis of the phantom appear as 1 × 1 (cm)2-2D grids, whereas between vertex planes, images are defined by 1 × 1 (cm)2-2D arrays of signal points. Image distortion is evaluated using a centroid algorithm that automatically identifies the center of each 3D-intersection and then calculates the deviations dx, dy, dz and dr for each vertex point; the results are presented as a color-coded 2D or 3D distribution of deviations. The phantom components and 3D-grid are machined to sub-millimeter accuracy, making the device uniquely suited to SRS applications; as such, we present it here in a form adapted for use with a Leksell stereotactic frame. Imaging reproducibility was assessed via repeated phantom imaging across ten back-to-back scans; 80%–90% of the differences in vertex deviations dx, dy, dz and dr between successive 3 T MRI scans were found to be  ⩽0.05 mm for both axial and coronal acquisitions, and over  >95% of the differences were observed to be  ⩽0.05 mm for repeated CT scans, clearly demonstrating excellent reproducibility. Applications of the 3D-phantom/analysis system are presented, using a 32-month time-course assessment of image distortion/gradient stability and statistical control chart for 1.5 T and 3 T GE TwinSpeed MRI

  13. Quality assurance program for prototype stereotactic system developed for neptun 10 Pc linac

    International Nuclear Information System (INIS)

    Khoshbin Khoshnazar, A.R.; Bahreyni Toossi, M.T.; Hashemiyan, A.R.; Bahreyni Toossi, M.T.; Salek, R.

    2005-01-01

    A prototype stereotactic radiosurgery set was designed and constructed for a Neptun 10 Pc linac that is currently being used at Imam Reza hospital in Mashad. Materials and Methods: A complete quality assurance program was designed and performed for the constructed system including isocentric accuracy test, localization accuracy test, dose delivery accuracy test and leakage radiation test. Target simulator, control alignment device and plexiglass phantom which were parts of the developed hardware were used to fulfill quality assurance program. Results: The average isocentric shift resulted from the gantry rotation and couch turning were respectively obtained to be 1.4 and 2 mm. The average localization error in the three coordinates was found to be 2.2 mm. The total treatment uncertainty due to all of the probable errors in the system was equal to 4.32 mm. The dose delivery accuracy test was carried out, the result indicated a 3.7% difference between the given and measured dose. Conclusion: The quality assurance tests showed consistent performance of the constructed system within the accepted limits; however, some inconsistency might exist in certain cases. The safety of stereotactic radiosurgery system method is increased when the overall uncertainty is minimized nd the treatment of the lesions adjacent to critical organs is avoided

  14. Clinical outcomes of gamma knife radiosurgery in the salvage treatment of patients with recurrent high-grade glioma.

    Science.gov (United States)

    Elaimy, Ameer L; Mackay, Alexander R; Lamoreaux, Wayne T; Demakas, John J; Fairbanks, Robert K; Cooke, Barton S; Lamm, Andrew F; Lee, Christopher M

    2013-12-01

    Previously published randomized evidence did not report a survival advantage for patients diagnosed with grade IV glioma who were treated with stereotactic radiosurgery followed by external beam radiation therapy and chemotherapy when compared to patients treated with external beam radiation therapy and chemotherapy alone. In recent years, gamma knife radiosurgery has become increasingly popular as a salvage treatment modality for patients diagnosed with recurrent high-grade glioma. The purpose of this article is to review the efficacy of gamma knife radiosurgery for patients who suffer from this malignancy. Retrospective, prospective, and randomized clinical studies published between the years 2000 and 2012 analyzing gamma knife radiosurgery for patients with high-grade glioma were reviewed. After assessing patient age, Karnofsky performance status, tumor histology, and extent of resection, gamma knife radiosurgery is a viable, minimally invasive treatment option for patients diagnosed with recurrent high-grade glioma. The available prospective and retrospective evidence suggests that gamma knife radiosurgery provides patients with a high local tumor control rate and a median survival after tumor recurrence ranging from 13 to 26 months. Gamma knife radiosurgery followed by chemotherapy for recurrent high-grade glioma may provide select patients with increased levels of survival. However, further investigation into this matter is needed due to the limited number of published reports. Additional clinical research is also needed to analyze the efficacy and radiation-related toxicities of fractionated gamma knife radiosurgery due to its potential to limit treatment-associated morbidity. Gamma knife radiosurgery is a safe and effective treatment option for select patients diagnosed with recurrent high-grade glioma. Although treatment outcomes have improved, further evidence in the form of phase III randomized trials is needed to assess the durability of treating

  15. Stereotactic intracranial implantation and in vivo bioluminescent imaging of tumor xenografts in a mouse model system of glioblastoma multiforme.

    Science.gov (United States)

    Baumann, Brian C; Dorsey, Jay F; Benci, Joseph L; Joh, Daniel Y; Kao, Gary D

    2012-09-25

    Glioblastoma multiforme (GBM) is a high-grade primary brain cancer with a median survival of only 14.6 months in humans despite standard tri-modality treatment consisting of surgical resection, post-operative radiation therapy and temozolomide chemotherapy. New therapeutic approaches are clearly needed to improve patient survival and quality of life. The development of more effective treatment strategies would be aided by animal models of GBM that recapitulate human disease yet allow serial imaging to monitor tumor growth and treatment response. In this paper, we describe our technique for the precise stereotactic implantation of bio-imageable GBM cancer cells into the brains of nude mice resulting in tumor xenografts that recapitulate key clinical features of GBM. This method yields tumors that are reproducible and are located in precise anatomic locations while allowing in vivo bioluminescent imaging to serially monitor intracranial xenograft growth and response to treatments. This method is also well-tolerated by the animals with low perioperative morbidity and mortality.

  16. Development of a head phantom to be used for quality control in stereotactic radiosurgery; Desenvolvimento de um simulador de cabeca para a aplicacao no controle da qualidade de radiocirurgia estereotaxica

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Nilseia Aparecida

    2010-05-15

    It was designed and developed a geometric acrylic head phantom (GHP) for Quality Assurance (QA) in Stereotactic Radiosurgery (SRS). Inside the phantom there are inserts that are able to accommodate acrylic targets representing the tumor tissue and organ at risk in the region cranial brain, the brain stem. The tumor tissue is represented by two semi-spheres of acrylic with a diameter of 13.0 mm and cavities in the central region for accommodation of a TLD-100 detector and a small radiochromic EBT Gafchromic filmstrip. The brain stem is represented by the two parts of acrylic cylinder with a diameter 18.0 mm, 38.0 mm length and cavities along the central region to accommodate the 5 detectors TLD-100 and yet another of EBT film. The distance tumor - brain stem is 2.0 mm. The experimental setup was filled with water, attached to the stereotactic frame to determine the coordinates of the target and underwent computed tomography (CT). Cf images were transferred to the SRS planning system BrainLab (BrainScan). The contours of the lesion and organ at risk were delineated and, through the technique of multiple circular arcs, the planning was conduced with five arches, one isocenter and a collimator of 17.5 mm from the combination between the table and gantry . The dose delivered to the isocenter of the lesion was 3.0 Gy and the total coverage of tumor volume corresponds to the 75% isodose. This experimental arrangement is subjected to radiosurgery treatment, after which the dosimeters are evaluated and their responses compared with the values of planned doses. The linear accelerator used was a Varian CLlNAC 2300 CID, photon beam of 6 MV, installed at the National Cancer Institute (INCA). For verification of dose distributions in 3D, the films were irradiated in three planes: sagittal, caronal and axial. The .films were scanned and digitized on a scanner Microtek ScanMaker 9800XL model. The dose distributions in irradiated films were compared with the distributions of doses

  17. Comparison of stereotactic radiosurgery (SRS) alone and whole brain radiotherapy (WBRT) plus a stereotactic boost (WBRT + SRS) for one to three brain metastases

    Energy Technology Data Exchange (ETDEWEB)

    Rades, Dirk [University Hospital Schleswig-Holstein, Luebeck (Germany). Department of Radiation Oncology]|[University Medical Center, Hamburg (Germany). Department of Radiation Oncology; Kueter, Jan-Dirk; Dunst, Juergen [University Hospital Schleswig-Holstein, Luebeck (Germany). Department of Radiation Oncology; Hornung, Dagmar [University Medical Center, Hamburg (Germany). Department of Radiation Oncology; Veninga, Theo; Hanssens, Patrick [Dr. Bernard Verbeeten Institute, Tilburg (Netherlands). Department of Radiation Oncology; Schild, Steven E. [Mayo Clinic Scottsdale, AZ (United States). Department of Radiation Oncology

    2008-12-15

    The best available treatment of patients with one to three brain metastases is still unclear. This study compared the results of stereotactic radiosurgery (SRS) alone and whole brain radiotherapy (WBRT) plus SRS (WBRT + SRS). Survival (OS), intracerebral control (IC), and local control of treated metastases (LC) were retrospectively analyzed in 144 patients receiving SRS alone (n = 93) or WBRT + SRS (n = 51). Eight additional potential prognostic factors were evaluated: age, gender, Eastern Cooperative Oncology Group performance score (ECOG-PS), tumor type, number of brain metastases, extracerebral metastases, recursive partitioning analysis (RPA) class, and interval from tumor diagnosis to irradiation. Subgroup analyses were performed for RPA class I and II patients. 1-year-OS was 53% after SRS and 56% after WBRT + SRS (p = 0.24). 1-year-IC rates were 51% and 66% (p = 0.015), respectively. 1-year-LC rates were 66% and 87% (p = 0.003), respectively. On multivariate analyses, OS was associated with age (p = 0.004), ECOG-PS (p = 0.005), extracerebral metastases (p < 0.001), RPA class (p < 0.001), and interval from tumor diagnosis to irradiation (p < 0.001). IC was associated with interval from tumor diagnosis to irradiation (p = 0.004) and almost with treatment (p = 0.09), and LC with treatment (p = 0.026) and almost with interval (p = 0.08). The results of the subgroup analyses were similar to those of the entire cohort. The increase in IC was stronger in RPA class I patients. WBRT + SRS resulted in better IC and LC but not better OS than SRS alone. Because also IC and LC are important end-points, additional WBRT appears justified in patients with one to three brain metastases, in particular in RPA class I patients. (orig.)

  18. Comparison of stereotactic radiosurgery (SRS) alone and whole brain radiotherapy (WBRT) plus a stereotactic boost (WBRT + SRS) for one to three brain metastases

    International Nuclear Information System (INIS)

    Rades, Dirk; University Medical Center, Hamburg; Kueter, Jan-Dirk; Dunst, Juergen; Hornung, Dagmar; Veninga, Theo; Hanssens, Patrick; Schild, Steven E.

    2008-01-01

    The best available treatment of patients with one to three brain metastases is still unclear. This study compared the results of stereotactic radiosurgery (SRS) alone and whole brain radiotherapy (WBRT) plus SRS (WBRT + SRS). Survival (OS), intracerebral control (IC), and local control of treated metastases (LC) were retrospectively analyzed in 144 patients receiving SRS alone (n = 93) or WBRT + SRS (n = 51). Eight additional potential prognostic factors were evaluated: age, gender, Eastern Cooperative Oncology Group performance score (ECOG-PS), tumor type, number of brain metastases, extracerebral metastases, recursive partitioning analysis (RPA) class, and interval from tumor diagnosis to irradiation. Subgroup analyses were performed for RPA class I and II patients. 1-year-OS was 53% after SRS and 56% after WBRT + SRS (p = 0.24). 1-year-IC rates were 51% and 66% (p = 0.015), respectively. 1-year-LC rates were 66% and 87% (p = 0.003), respectively. On multivariate analyses, OS was associated with age (p = 0.004), ECOG-PS (p = 0.005), extracerebral metastases (p < 0.001), RPA class (p < 0.001), and interval from tumor diagnosis to irradiation (p < 0.001). IC was associated with interval from tumor diagnosis to irradiation (p = 0.004) and almost with treatment (p = 0.09), and LC with treatment (p = 0.026) and almost with interval (p = 0.08). The results of the subgroup analyses were similar to those of the entire cohort. The increase in IC was stronger in RPA class I patients. WBRT + SRS resulted in better IC and LC but not better OS than SRS alone. Because also IC and LC are important end-points, additional WBRT appears justified in patients with one to three brain metastases, in particular in RPA class I patients. (orig.)

  19. Radiosurgery in the Management of Intractable Mesial Temporal Lobe Epilepsy.

    Science.gov (United States)

    Peñagarícano, José; Serletis, Demitre

    2015-09-01

    Mesial temporal lobe epilepsy (MTLE) describes recurrent seizure activity originating from the depths of the temporal lobe. MTLE patients who fail two trials of medication now require testing for surgical candidacy at an epilepsy center. For these individuals, temporal lobectomy offers the greatest likelihood for seizure-freedom (up to 80-90%); unfortunately, this procedure remains largely underutilized. Moreover, for select patients unable to tolerate open surgery, novel techniques are emerging for selective ablation of the mesial temporal structures, including stereotactic radiosurgery (SRS). We present here a review of SRS as a potential therapy for MTLE, when open surgery is not an option.

  20. Neural stem cell sparing by linac based intensity modulated stereotactic radiotherapy in intracranial tumors

    International Nuclear Information System (INIS)

    Oehler, Julia; Brachwitz, Tim; Wendt, Thomas G; Banz, Nico; Walther, Mario; Wiezorek, Tilo

    2013-01-01

    Neurocognitive decline observed after radiotherapy (RT) for brain tumors in long time survivors is attributed to radiation exposure of the hippocampus and the subventricular zone (SVZ). The potential of sparing capabilities for both structures by optimized intensity modulated stereotactic radiotherapy (IMSRT) is investigated. Brain tumors were irradiated by stereotactic 3D conformal RT or IMSRT using m3 collimator optimized for PTV and for sparing of the conventional OARs (lens, retina, optic nerve, chiasm, cochlea, brain stem and the medulla oblongata). Retrospectively both hippocampi and SVZ were added to the list of OAR and their dose volume histograms were compared to those from two newly generated IMSRT plans using 7 or 14 beamlets (IMSRT-7, IMSRT-14) dedicated for optimized additional sparing of these structures. Conventional OAR constraints were kept constant. Impact of plan complexity and planning target volume (PTV) topography on sparing of both hippocampi and SVZ, conformity index (CI), the homogeneity index (HI) and quality of coverage (QoC) were analyzed. Limits of agreement were used to compare sparing of stem cell niches with either IMSRT-7 or IMSRT-14. The influence of treatment technique related to the topography ratio between PTV and OARs, realized in group A-D, was assessed by a mixed model. In 47 patients CI (p ≤ 0.003) and HI (p < 0.001) improved by IMSRT-7, IMSRT-14, QoC remained stable (p ≥ 0.50) indicating no compromise in radiotherapy. 90% of normal brain was exposed to a significantly higher dose using IMSRT. IMSRT-7 plans resulted in significantly lower biologically effective doses at all four neural stem cell structures, while contralateral neural stem cells are better spared compared to ipsilateral. A further increase of the number of beamlets (IMSRT-14) did not improve sparing significantly, so IMSRT-7 and IMSRT-14 can be used interchangeable. Patients with tumors contacting neither the subventricular zone nor the cortex benefit

  1. Study Protocol: Early Stereotactic Gamma Knife Radiosurgery to Residual Tumor After Surgery of Newly Diagnosed Glioblastoma (Gamma-GBM).

    Science.gov (United States)

    Brehmer, Stefanie; Grimm, Mario Alexander; Förster, Alex; Seiz-Rosenhagen, Marcel; Welzel, Grit; Stieler, Florian; Wenz, Frederik; Groden, Christoph; Mai, Sabine; Hänggi, Daniel; Giordano, Frank Anton

    2018-04-24

    Glioblastoma (GBM) is the most common malignant brain tumor in adult patients. Tumor recurrence commonly occurs around the resection cavity, especially after subtotal resection (STR). Consequently, the extent of resection correlates with overall survival (OS), suggesting that depletion of postoperative tumor remnants will improve outcome. To assess safety and efficacy of adding stereotactic radiosurgery (SRS) to the standard treatment of GBM in patients with postoperative residual tumor. Gamma-GBM is a single center, open-label, prospective, single arm, phase II study that includes patients with newly diagnosed GBM (intraoperative via frozen sections) who underwent STR (residual tumor will be identified by native and contrast enhanced T1-weighted magnetic resonance imaging scans). All patients will receive SRS with 15 Gy (prescribed to the 50% isodose enclosing all areas of residual tumor) early (within 24-72 h) after surgery. Thereafter, all patients undergo standard-of-care therapy for GBM (radiochemotherapy with 60 Gy external beam radiotherapy [EBRT] plus concomitant temozolomide and 6 cycles of adjuvant temozolomide chemotherapy). The primary outcome is median progression-free survival, secondary outcomes are median OS, occurrence of radiation induced acute (3 mo post-SRS) neurotoxicity and incidence of symptomatic radionecrosis. We expect to detect efficacy and safety signals by the immediate application of SRS to standard-of-care therapy in newly diagnosed GBM. Early postoperative SRS to areas of residual tumor could bridge the therapeutic gap between surgery and adjuvant therapies.

  2. Water Exchange Rate Constant as a Biomarker of Treatment Efficacy in Patients With Brain Metastases Undergoing Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Mehrabian, Hatef; Desmond, Kimberly L.; Chavez, Sofia; Bailey, Colleen; Rola, Radoslaw; Sahgal, Arjun; Czarnota, Gregory J.; Soliman, Hany; Martel, Anne L.; Stanisz, Greg J.

    2017-01-01

    Purpose: This study was designed to evaluate whether changes in metastatic brain tumors after stereotactic radiosurgery (SRS) can be seen with quantitative MRI early after treatment. Methods and Materials: Using contrast-enhanced MRI, a 3-water-compartment tissue model consisting of intracellular (I), extracellular-extravascular (E), and vascular (V) compartments was used to assess the intra–extracellular water exchange rate constant (k IE ), efflux rate constant (k ep ), and water compartment volume fractions (M 0,I , M 0,E , M 0,V ). In this prospective study, 19 patients were MRI-scanned before treatment and 1 week and 1 month after SRS. The change in model parameters between the pretreatment and 1-week posttreatment scans was correlated to the change in tumor volume between pretreatment and 1-month posttreatment scans. Results: At 1 week k IE differentiated (P<.001) tumors that had partial response from tumors with stable and progressive disease, and a high correlation (R=−0.76, P<.001) was observed between early changes in the k IE and tumor volume change 1 month after treatment. Other model parameters had lower correlation (M 0,E ) or no correlation (k ep , M 0,V ). Conclusions: This is the first study that measured k IE early after SRS, and it found that early changes in k IE (1 week after treatment) highly correlated with long-term tumor response and could predict the extent of tumor shrinkage at 1 month after SRS.

  3. Cone-beam CT image contrast and attenuation-map linearity improvement (CALI) for brain stereotactic radiosurgery procedures

    Science.gov (United States)

    Hashemi, Sayed Masoud; Lee, Young; Eriksson, Markus; Nordström, Hâkan; Mainprize, James; Grouza, Vladimir; Huynh, Christopher; Sahgal, Arjun; Song, William Y.; Ruschin, Mark

    2017-03-01

    A Contrast and Attenuation-map (CT-number) Linearity Improvement (CALI) framework is proposed for cone-beam CT (CBCT) images used for brain stereotactic radiosurgery (SRS). The proposed framework is used together with our high spatial resolution iterative reconstruction algorithm and is tailored for the Leksell Gamma Knife ICON (Elekta, Stockholm, Sweden). The incorporated CBCT system in ICON facilitates frameless SRS planning and treatment delivery. The ICON employs a half-cone geometry to accommodate the existing treatment couch. This geometry increases the amount of artifacts and together with other physical imperfections causes image inhomogeneity and contrast reduction. Our proposed framework includes a preprocessing step, involving a shading and beam-hardening artifact correction, and a post-processing step to correct the dome/capping artifact caused by the spatial variations in x-ray energy generated by bowtie-filter. Our shading correction algorithm relies solely on the acquired projection images (i.e. no prior information required) and utilizes filtered-back-projection (FBP) reconstructed images to generate a segmented bone and soft-tissue map. Ideal projections are estimated from the segmented images and a smoothed version of the difference between the ideal and measured projections is used in correction. The proposed beam-hardening and dome artifact corrections are segmentation free. The CALI was tested on CatPhan, as well as patient images acquired on the ICON system. The resulting clinical brain images show substantial improvements in soft contrast visibility, revealing structures such as ventricles and lesions which were otherwise un-detectable in FBP-reconstructed images. The linearity of the reconstructed attenuation-map was also improved, resulting in more accurate CT#.

  4. A national survey of the availability of intensity-modulated radiation therapy and stereotactic radiosurgery in Canada

    International Nuclear Information System (INIS)

    AlDuhaiby, Eman Z; Breen, Stephen; Bissonnette, Jean-Pierre; Sharpe, Michael; Mayhew, Linda; Tyldesley, Scott; Wilke, Derek R; Hodgson, David C

    2012-01-01

    The timely and appropriate adoption of new radiation therapy (RT) technologies is a challenge both in terms of providing of optimal patient care and managing health care resources. Relatively little is known regarding the rate at which new RT technologies are adopted in different jurisdictions, and the barriers to implementation of these technologies. Surveys were sent to all radiation oncology department heads in Canada regarding the availability of RT equipment from 2006 to 2010. Data were collected concerning the availability and use of Intensity Modulated Radiation Therapy (IMRT) and stereotactic radiosurgery (SRS), and the obstacles to implementation of these technologies. IMRT was available in 37% of responding centers in 2006, increasing to 87% in 2010. In 2010, 72% of centers reported that IMRT was available for all patients who might benefit, and 37% indicated that they used IMRT for 'virtually all' head and neck patients. SRS availability increased from 26% in 2006 to 42.5% in 2010. Eighty-two percent of centers reported that patients had access to SRS either directly or by referral. The main barriers for IMRT implementation included the need to train or hire treatment planning staff, whereas barriers to SRS implementation mostly included the need to purchase and/or upgrade existing planning software and equipment. The survey showed a growing adoption of IMRT and SRS in Canada, although the latter was available in less than half of responding centers. Barriers to implementation differed for IMRT compared to SRS. Enhancing human resources is an important consideration in the implementation of new RT technologies, due to the multidisciplinary nature of the planning and treatment process

  5. Effect of prophylactic hyperbaric oxygen treatment for radiation-induced brain injury after stereotactic radiosurgery of brain metastases

    International Nuclear Information System (INIS)

    Ohguri, Takayuki; Imada, Hajime; Kohshi, Kiyotaka; Kakeda, Shingo; Ohnari, Norihiro; Morioka, Tomoaki; Nakano, Keita; Konda, Nobuhide; Korogi, Yukunori

    2007-01-01

    Purpose: The purpose of the present study was to evaluate the prophylactic effect of hyperbaric oxygen (HBO) therapy for radiation-induced brain injury in patients with brain metastasis treated with stereotactic radiosurgery (SRS). Methods and Materials: The data of 78 patients presenting with 101 brain metastases treated with SRS between October 1994 and September 2003 were retrospectively analyzed. A total of 32 patients with 47 brain metastases were treated with prophylactic HBO (HBO group), which included all 21 patients who underwent subsequent or prior radiotherapy and 11 patients with common predictors of longer survival, such as inactive extracranial tumors and younger age. The other 46 patients with 54 brain metastases did not undergo HBO (non-HBO group). Radiation-induced brain injuries were divided into two categories, white matter injury (WMI) and radiation necrosis (RN), on the basis of imaging findings. Results: Radiation-induced brain injury occurred in 5 lesions (11%) in the HBO group (2 WMIs and 3 RNs) and in 11 (20%) in the non-HBO group (9 WMIs and 2 RNs). The WMI was less frequent for the HBO group than for the non-HBO group (p = 0.05), although multivariate analysis by logistic regression showed that WMI was not significantly correlated with HBO (p = 0.07). The 1-year actuarial probability of WMI was significantly better for the HBO group (2%) than for the non-HBO group (36%) (p < 0.05). Conclusions: The present study showed a potential value of prophylactic HBO for Radiation-induced WMIs, which justifies further evaluation to confirm its definite benefit

  6. Extracranial Facial Nerve Schwannoma Treated by Hypo-fractionated CyberKnife Radiosurgery

    OpenAIRE

    Sasaki, Ayaka; Miyazaki, Shinichiro; Hori, Tomokatsu

    2016-01-01

    Facial nerve schwannoma is a rare intracranial tumor. Treatment for this benign tumor has been controversial. Here, we report a case of extracranial facial nerve schwannoma treated successfully by hypo-fractionated CyberKnife (Accuray, Sunnyvale, CA) radiosurgery?and discuss the efficacy of this treatment. A 34-year-old female noticed a swelling in her right mastoid process. The lesion enlarged over a seven-month period, and she experienced facial spasm on the right side. She was diagnosed wi...

  7. Present situation and prospect of gamma knife radiosurgery for functional brain disorders

    International Nuclear Information System (INIS)

    Zhang Yongquan; Zhao Xianjun; Liu Wenli

    2002-01-01

    With the evolution of imaging technology in the past two decades, currently anatomic targets including the trigeminal nerve (for trigeminal neuralgia), the thalamus (for tremor or pain), the cingulate gyrus, anterior internal capsule or amygdala (for pain or psychiatric illness), the globus pallidum (for symptoms of Parkinson's disease), and the hippocampus (for epilepsy) can be precisely located with computerized tomography, magnetic resonance image, single photon emission computerized tomography and positron emission tomography; stereotactic radiosurgery gradually tends to perfection. Gamma knife therapy for nervous functional disorders has become the focus of interest in clinical study

  8. Radiosurgery alone for 5 or more brain metastases: expert opinion survey.

    Science.gov (United States)

    Knisely, Jonathan P S; Yamamoto, Masaaki; Gross, Cary P; Castrucci, William A; Jokura, Hidefumi; Chiang, Veronica L S

    2010-12-01

    Oligometastatic brain metastases may be treated with stereotactic radiosurgery (SRS) alone, but no consensus exists as to when SRS alone would be appropriate. A survey was conducted at 2 radiosurgery meetings to determine which factors SRS practitioners emphasize in recommending SRS alone, and what physician characteristics are associated with recommending SRS alone for ≥ 5 metastases. All physicians attending the 8th Biennial Congress and Exhibition of the International Stereotactic Radiosurgery Society in June 2007 and the 18th Annual Meeting of the Japanese Society of Stereotactic Radiosurgery in July 2009 were asked to complete a questionnaire ranking 14 clinical factors on a 5-point Likert-type scale (ranging from 1 = not important to 5 = very important) to determine how much each factor might influence a decision to recommend SRS alone for brain metastases. Results were condensed into a single dichotomous outcome variable of "influential" (4-5) versus "not influential" (1-3). Respondents were also asked to complete the statement: "In general, a reasonable number of brain metastases treatable by SRS alone would be, at most, ___." The characteristics of physicians willing to recommend SRS alone for ≥ 5 metastases were assessed. Chi-square was used for univariate analysis, and logistic regression for multivariate analysis. The final study sample included 95 Gamma Knife and LINAC-using respondents (54% Gamma Knife users) in San Francisco and 54 in Sendai (48% Gamma Knife users). More than 70% at each meeting had ≥ 5 years experience with SRS. Sixty-five percent in San Francisco and 83% in Sendai treated ≥ 30 cases annually with SRS. The highest number of metastases considered reasonable to treat with SRS alone in both surveys was 50. In San Francisco, the mean and median numbers of metastases considered reasonable to treat with SRS alone were 6.7 and 5, while in Sendai they were 11 and 10. In the San Francisco sample, the clinical factors identified to be

  9. A new stereotactic apparatus guided by computed tomography

    International Nuclear Information System (INIS)

    Huk, W.J.

    1981-01-01

    The accurate information provided by computer tomography about existence, shape, and localization of intracranial neoplasms in an early phase and in inaccessible regions have improved the diagnostics greatly, so that these lie far ahead of the therapeutic possibilities for brain tumors. To reduce this wide margin we have developed a new targeting device which makes a stereotactic approach to central lesions under sight-control by computed tomography within the computed tomography-scanner possible. With the help of this simple device we are now able to perform stereotactic procedures for tumor biopsy guided by computed tomography, needling and drainage of abscesses and cysts, and finally for the implantation of radioactive material for the interstitial radiotherapy of inoperable cysts and tumors. (orig.) [de

  10. Radiosurgery for cerebral arteriovenous malformation during pregnancy: A case report focusing on fetal exposure to radiation

    OpenAIRE

    Nagayama, Kazuki; Kurita, Hiroki; Tonari, Ayako; Takayama, Makoto; Shiokawa, Yoshiaki

    2010-01-01

    Introduction: We present the case of a pregnant woman who underwent linear accelerator (LINAC)-based stereotactic radiosurgery (SRS) and we discuss the fetal exposure to radiation. Clinical Presentation: A 20-year-old woman at 18 weeks of gestation presented with right cerebral hemorrhage and underwent urgent evacuation of the hematoma. She recovered well after surgery, but cerebral angiography after the surgery revealed a small deeply seated arteriovenous malformation (AVM) in the right fron...

  11. Gamma Knife radiosurgery in pituitary adenomas: Why, who, and how to treat?

    Science.gov (United States)

    Castinetti, Frederic; Brue, Thierry

    2010-08-01

    Pituitary adenomas are benign tumors that can be either secreting (acromegaly, Cushing's disease, prolactinomas) or non-secreting. Transsphenoidal neurosurgery is the gold standard treatment; however, it is not always effective. Gamma Knife radiosurgery is a specific modality of stereotactic radiosurgery, a precise radiation technique. Several studies reported the efficacy and low risk of adverse effects induced by this technique: in secreting pituitary adenomas, hypersecretion is controlled in about 50% of cases and tumor volume is stabilized or decreased in 80-90% of cases, making Gamma Knife a valuable adjunctive or first-line treatment. As hormone levels decrease progressively, the main drawback is the longer time to remission (12-60 months), requiring an additional treatment during this period. Hypopituitarism is the main side effect, observed in 20-40% cases. Gamma Knife is thus useful in the therapeutic algorithms of pituitary adenomas in well-defined indications, mainly low secreting small lesions well identified on magnetic resonance imaging (MRI).

  12. Planned Two-Fraction Proton Beam Stereotactic Radiosurgery for High-Risk Inoperable Cerebral Arteriovenous Malformations

    Energy Technology Data Exchange (ETDEWEB)

    Hattangadi, Jona A. [Harvard Radiation Oncology Program, Boston, MA (United States); Chapman, Paul H. [Department of Neurosurgery, Massachusetts General Hospital, Boston, MA (United States); Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA (United States); Bussiere, Marc R.; Niemierko, Andrzej [Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA (United States); Ogilvy, Christopher S. [Department of Neurosurgery, Massachusetts General Hospital, Boston, MA (United States); Rowell, Alison; Daartz, Juliane; Loeffler, Jay S. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA (United States); Shih, Helen A., E-mail: hshih@partners.org [Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA (United States)

    2012-06-01

    Purpose: To evaluate patients with high-risk cerebral arteriovenous malformations (AVMs), based on eloquent brain location or large size, who underwent planned two-fraction proton stereotactic radiosurgery (PSRS). Methods and Materials: From 1991 to 2009, 59 patients with high-risk cerebral AVMs received two-fraction PSRS. Median nidus volume was 23 cc (range, 1.4-58.1 cc), 70% of cases had nidus volume {>=}14 cc, and 34% were in critical locations (brainstem, basal ganglia). Median AVM score based on age, AVM size, and location was 3.19 (range, 0.9-6.9). Many patients had prior surgery or embolization (40%) or prior PSRS (12%). The most common prescription was 16 Gy radiobiologic equivalent (RBE) in two fractions, prescribed to the 90% isodose. Results: At a median follow-up of 56.1 months, 9 patients (15%) had total and 20 patients (34%) had partial obliteration. Patients with total obliteration received higher total dose than those with partial or no obliteration (mean dose, 17.6 vs. 15.5 Gy (RBE), p = 0.01). Median time to total obliteration was 62 months (range, 23-109 months), and 5-year actuarial rate of partial or total obliteration was 33%. Five-year actuarial rate of hemorrhage was 22% (95% confidence interval, 12.5%-36.8%) and 14% (n = 8) suffered fatal hemorrhage. Lesions with higher AVM scores were more likely to hemorrhage (p = 0.024) and less responsive to radiation (p = 0.026). The most common complication was Grade 1 headache acutely (14%) and long term (12%). One patient developed a Grade 2 generalized seizure disorder, and two had mild neurologic deficits. Conclusions: High-risk AVMs can be safely treated with two-fraction PSRS, although total obliteration rate is low and patients remain at risk for future hemorrhage. Future studies should include higher doses or a multistaged PSRS approach for lesions more resistant to obliteration with radiation.

  13. Volumetric Modulated Arc-Based Hypofractionated Stereotactic Radiotherapy for the Treatment of Selected Intracranial Arteriovenous Malformations: Dosimetric Report and Early Clinical Experience

    Energy Technology Data Exchange (ETDEWEB)

    Subramanian, Sai; Srinivas, Chilukuri; Ramalingam, K.; Babaiah, M.; Swamy, S. Thirumalai; Arun, G.; Kathirvel, M.; Ashok, S. [Yashoda Super Specialty Hospital, Hyderabad (India); Clivio, Alessandro [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland); Fogliata, Antonella, E-mail: antonella.fogliata-cozzi@eoc.ch [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland); Nicolini, Giorgia [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland); Rao, K. Srinivasa; Reddy, T. Pratap; Amit, Jotwani [Yashoda Super Specialty Hospital, Hyderabad (India); Vanetti, Eugenio; Cozzi, Luca [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland)

    2012-03-01

    Purpose: To evaluate, with a dosimetric and clinical feasibility study, RapidArc (a volumetric modulated arc technique) for hypofractionated stereotactic radiotherapy treatment of large arteriovenous malformations (AVMs). Methods and Materials: Nine patients were subject to multimodality imaging (magnetic resonance, computed tomography, and digital subtraction angiography) to determine nidus and target volumes, as well as involved organs at risk (optical structures, inner ear, brain stem). Plans for multiple intensity-modulated arcs with a single isocenter were optimized for a fractionation of 25 Gy in 5 fractions. All plans were optimized for 6-MV photon beams. Dose-volume histograms were analyzed to assess plan quality. Delivery parameters were reported to appraise technical features of RapidArc, and pretreatment quality assurance measurements were carried out to report on quality of delivery. Results: Average size of AVM nidus was 26.2 cm{sup 3}, and RapidArc plans provided complete target coverage with minimal overdosage (V{sub 100%} = 100% and V{sub 110%} < 1%) and excellent homogeneity (<6%). Organs at risk were highly spared. The D{sub 1%} to chiasm, eyes, lenses, optic nerves, and brainstem (mean {+-} SD) was 6.4 {+-} 8.3, 1.9 {+-} 3.8, 2.3 {+-} 2.2, 0.7 {+-} 0.9, 4.4 {+-} 7.2, 12.2 {+-} 9.6 Gy, respectively. Conformity index (CI{sub 95%}) was 2.2 {+-} 0.1. The number of monitor units per gray was 277 {+-} 45, total beam-on time was 2.5 {+-} 0.3 min. Planning vs. delivery {gamma} pass rate was 98.3% {+-} 0.9%. None of the patients developed acute toxicity. With a median follow-up of 9 months, 3 patients presented with deterioration of symptoms and were found to have postradiation changes but responded symptomatically to steroids. These patients continue to do well on follow-up. One patient developed headache and seizures, which was attributed to intracranial bleed, confirmed on imaging. Conclusion: Hypofractionated stereotactic radiotherapy can be

  14. Preliminary experience with frameless stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Buatti, John M.; Bova, Francis J.; Friedman, William A.; Meeks, Sanford L.; Marcus, Robert B.; Mickle, J. Parker; Ellis, Thomas L.; Mendenhall, William M.

    1998-01-01

    Purpose: To report initial clinical experience with a novel high-precision stereotactic radiotherapy system. Methods and Materials: Sixty patients ranging in age from 2 to 82 years received a total of 1426 treatments with the University of Florida frameless stereotactic radiotherapy system. Of the total, 39 (65%) were treated with stereotactic radiotherapy (SRT) alone, and 21 (35%) received SRT as a component of radiotherapy. Pathologic diagnoses included meningiomas (15 patients), low-grade astrocytomas (11 patients), germinomas (9 patients), and craniopharyngiomas (5 patients). The technique was used as means of dose escalation in 11 patients (18%) with aggressive tumors. Treatment reproducibility was measured by comparing bite plate positioning registered by infrared light-emitting diodes (IRLEDs) with the stereotactic radiosurgery reference system, and with measurements from each treatment arc for the 1426 daily treatments (5808 positions). We chose 0.3 mm vector translation error and 0.3 deg. rotation about each axis as the maximum tolerated misalignment before treating each arc. Results: With a mean follow-up of 11 months, 3 patients had recurrence of malignant disease. Acute side effects were minimal. Of 11 patients with low grade astrocytomas, 4 (36%) had cerebral edema and increased enhancement on MR scans in the first year, and 2 required steroids. All had resolution and marked tumor involution on follow-up imaging. Bite plate reproducibility was as follows. Translational errors: anterior-posterior, 0.01 ± 0.10; lateral, 0.02 ± 0.07; axial, 0.01 ± 0.10. Rotational errors (degrees): anterior-posterior, 0.00 ± 0.03; lateral, 0.00 ± 0.06; axial, 0.01 ± 0.04. No patient treatment was delivered beyond the maximum tolerated misalignment. Daily treatment was delivered in approximately 15 min per patient. Conclusion: Our initial experience with stereotactic radiotherapy using the infrared camera guidance system was good. Patient selection and treatment

  15. Failure mode and effects analysis based risk profile assessment for stereotactic radiosurgery programs at three cancer centers in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Flavia C., E-mail: flavitiz@gmail.com [CNEN—Comissao Nacional de Energia Nuclear, Rio de Janeiro, RJ 22290-901, Brazil and LCR/UERJ—Laboratorio de Ciencias Radiologicas/Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ 20550-013 (Brazil); Almeida, Carlos E. de [LCR/UERJ—Laboratorio de Ciencias Radiologicas/Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ 20550-013 (Brazil); Saiful Huq, M. [Department of Radiation Oncology, University of Pittsburgh Cancer Institute and UPMC Cancer Center, Pittsburgh, Pennsylvania 15232 (United States)

    2016-01-15

    Purpose: The goal of this study was to evaluate the safety and quality management program for stereotactic radiosurgery (SRS) treatment processes at three radiotherapy centers in Brazil by using three industrial engineering tools (1) process mapping, (2) failure modes and effects analysis (FMEA), and (3) fault tree analysis. Methods: The recommendations of Task Group 100 of American Association of Physicists in Medicine were followed to apply the three tools described above to create a process tree for SRS procedure for each radiotherapy center and then FMEA was performed. Failure modes were identified for all process steps and values of risk priority number (RPN) were calculated from O, S, and D (RPN = O × S × D) values assigned by a professional team responsible for patient care. Results: The subprocess treatment planning was presented with the highest number of failure modes for all centers. The total number of failure modes were 135, 104, and 131 for centers I, II, and III, respectively. The highest RPN value for each center is as follows: center I (204), center II (372), and center III (370). Failure modes with RPN ≥ 100: center I (22), center II (115), and center III (110). Failure modes characterized by S ≥ 7, represented 68% of the failure modes for center III, 62% for center II, and 45% for center I. Failure modes with RPNs values ≥100 and S ≥ 7, D ≥ 5, and O ≥ 5 were considered as high priority in this study. Conclusions: The results of the present study show that the safety risk profiles for the same stereotactic radiotherapy process are different at three radiotherapy centers in Brazil. Although this is the same treatment process, this present study showed that the risk priority is different and it will lead to implementation of different safety interventions among the centers. Therefore, the current practice of applying universal device-centric QA is not adequate to address all possible failures in clinical processes at different

  16. Failure mode and effects analysis based risk profile assessment for stereotactic radiosurgery programs at three cancer centers in Brazil

    International Nuclear Information System (INIS)

    Teixeira, Flavia C.; Almeida, Carlos E. de; Saiful Huq, M.

    2016-01-01

    Purpose: The goal of this study was to evaluate the safety and quality management program for stereotactic radiosurgery (SRS) treatment processes at three radiotherapy centers in Brazil by using three industrial engineering tools (1) process mapping, (2) failure modes and effects analysis (FMEA), and (3) fault tree analysis. Methods: The recommendations of Task Group 100 of American Association of Physicists in Medicine were followed to apply the three tools described above to create a process tree for SRS procedure for each radiotherapy center and then FMEA was performed. Failure modes were identified for all process steps and values of risk priority number (RPN) were calculated from O, S, and D (RPN = O × S × D) values assigned by a professional team responsible for patient care. Results: The subprocess treatment planning was presented with the highest number of failure modes for all centers. The total number of failure modes were 135, 104, and 131 for centers I, II, and III, respectively. The highest RPN value for each center is as follows: center I (204), center II (372), and center III (370). Failure modes with RPN ≥ 100: center I (22), center II (115), and center III (110). Failure modes characterized by S ≥ 7, represented 68% of the failure modes for center III, 62% for center II, and 45% for center I. Failure modes with RPNs values ≥100 and S ≥ 7, D ≥ 5, and O ≥ 5 were considered as high priority in this study. Conclusions: The results of the present study show that the safety risk profiles for the same stereotactic radiotherapy process are different at three radiotherapy centers in Brazil. Although this is the same treatment process, this present study showed that the risk priority is different and it will lead to implementation of different safety interventions among the centers. Therefore, the current practice of applying universal device-centric QA is not adequate to address all possible failures in clinical processes at different

  17. Patient-specific quality assurance for intracranial cases in robotic radiosurgery system.

    Science.gov (United States)

    Koksal, Canan; Akbas, Ugur; Donmez Kesen, Nazmiye; Okutan, Murat; Bilge, Hatice; Kemikler, Gonul

    2018-01-01

    The purpose of this study was to perform pretreatment patient-specific quality assurance (QA) for intracranial irradiation using CyberKnife with an ion chamber. Twenty-five intracranial plans created using the ray-tracing algorithm were used for this study. Computed tomography (CT) images of the water-equivalent RW3 slab phantom with PinPoint ionization chamber were acquired with 1-mm slice thickness and transferred to the MultiPlan treatment planning system (TPS). Four gold fiducial markers embedded into two different plates were used to tracking during the irradiation. Intracranial plans were transferred to CT images of the RW3 phantom. The isodose curves and sensitive volume of ion chamber were overlapped. Point dose measurements were performed three times and the mean point doses were calculated for each plan. The mean doses measured by the PinPoint ion chamber were compared with those of the calculated by MultiPlan TPS in the sensitive volume of PinPoint. The mean percentage difference (MPD) in point dose measurements was -2.44±1.97 for 25 plans. The maximum and minimum percentage differences between the measured and calculated absolute point doses were -7.14 and 0.23, respectively. The MPD was -1.70±1.90 for 12 plans using a fixed collimator and -3.11±1.86 for 13 plans using an IRIS cone. Point dose measurement is a reliable and functional method for pre-treatment patient-specific QA in intracranial CyberKnife plans. Point dose verification should be performed to correct any possible errors prior to patient treatment. It is recommended for use in patient-specific QA process in the CyberKnife plans.

  18. Pleomorphic adenocarcinoma of the lacrimal gland with multiple intracranial and spinal metastases

    Directory of Open Access Journals (Sweden)

    Kim Se

    2007-03-01

    Full Text Available Abstract Background Pleomorphic adenoma of the lacrimal gland is known to undergo malignant transformation when incompletely excised. Even if such a malignant change occurs, intracranial direct invasion and leptomeningeal seeding are seldom encountered. Case presentation A 50-year-old woman presented with malignant transformation associated with both intracranial invasion and multiple intracranial and spinal disseminations in the third recurrence of pleomorphic adenoma of the lacrimal gland, 6 years after initial treatment. MRI demonstrated increased extent of orbital mass, extending to the cavernous sinus. The patient underwent intensity-modulated radiation therapy (IMRT and Gamma Knife radiosurgery. Follow-up MRI showed multiple leptomeningeal disseminations to the intracranium and spine. Conclusion It is important to recognize that leptomeningeal intracranial and spinal disseminations of pleomorphic adenocarcinoma can occur, although it is extremely rare. To our knowledge, we report the first case of pleomorphic adenocarcinoma of the lacrimal gland presumably metastasizing to the intracranium and spine.

  19. Monte Carlo simulation of the Leksell Gamma KnifeTM: II. Effects of heterogeneous versus homogeneous media for stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Moskvin, Vadim; Timmerman, Robert; DesRosiers, Colleen; Randall, Marcus; DesRosiers, Paul; Dittmer, Phil; Papiez, Lech

    2004-01-01

    The absence of electronic equilibrium in the vicinity of bone-tissue or air-tissue heterogeneity in the head can misrepresent deposited dose with treatment planning algorithms that assume all treatment volume as homogeneous media. In this paper, Monte Carlo simulation (PENELOPE) and measurements with a specially designed heterogeneous phantom were applied to investigate the effect of air-tissue and bone-tissue heterogeneity on dose perturbation with the Leksell Gamma Knife TM . The dose fall-off near the air-tissue interface caused by secondary electron disequilibrium leads to overestimation of dose by the vendor supplied treatment planning software (GammaPlan TM ) at up to 4 mm from an interface. The dose delivered to the target area away from an air-tissue interface may be underestimated by up to 7% by GammaPlan TM due to overestimation of attenuation of photon beams passing through air cavities. While the underdosing near the air-tissue interface cannot be eliminated with any plug pattern, the overdosage due to under-attenuation of the photon beams in air cavities can be eliminated by plugging the sources whose beams intersect the air cavity. Little perturbation was observed next to bone-tissue interfaces. Monte Carlo results were confirmed by measurements. This study shows that the employed Monte Carlo treatment planning is more accurate for precise dosimetry of stereotactic radiosurgery with the Leksell Gamma Knife TM for targets in the vicinity of air-filled cavities

  20. Assessment of targeting accuracy of a low-energy stereotactic radiosurgery treatment for age-related macular degeneration

    Science.gov (United States)

    Taddei, Phillip J.; Chell, Erik; Hansen, Steven; Gertner, Michael; Newhauser, Wayne D.

    2010-12-01

    Age-related macular degeneration (AMD), a leading cause of blindness in the United States, is a neovascular disease that may be controlled with radiation therapy. Early patient outcomes of external beam radiotherapy, however, have been mixed. Recently, a novel multimodality treatment was developed, comprising external beam radiotherapy and concomitant treatment with a vascular endothelial growth factor inhibitor. The radiotherapy arm is performed by stereotactic radiosurgery, delivering a 16 Gy dose in the macula (clinical target volume, CTV) using three external low-energy x-ray fields while adequately sparing normal tissues. The purpose of our study was to test the sensitivity of the delivery of the prescribed dose in the CTV using this technique and of the adequate sparing of normal tissues to all plausible variations in the position and gaze angle of the eye. Using Monte Carlo simulations of a 16 Gy treatment, we varied the gaze angle by ±5° in the polar and azimuthal directions, the linear displacement of the eye ±1 mm in all orthogonal directions, and observed the union of the three fields on the posterior wall of spheres concentric with the eye that had diameters between 20 and 28 mm. In all cases, the dose in the CTV fluctuated <6%, the maximum dose in the sclera was <20 Gy, the dose in the optic disc, optic nerve, lens and cornea were <0.7 Gy and the three-field junction was adequately preserved. The results of this study provide strong evidence that for plausible variations in the position of the eye during treatment, either by the setup error or intrafraction motion, the prescribed dose will be delivered to the CTV and the dose in structures at risk will be kept far below tolerance doses.