WorldWideScience

Sample records for intracavity biconical taper

  1. Narrowband spectral filter based on biconical tapered fiber

    Science.gov (United States)

    Celaschi, Sergio; Malheiros-Silveira, Gilliard N.

    2018-02-01

    The ease of fabrication and compactness of devices based on tapered optical fibers contribute to its potential using in several applications ranging from telecommunication components to sensing devices. In this work, we proposed, fabricated, and characterized a spectral filter made of biconical taper from a coaxial optical fiber. This filter is defined by adiabatically tapering a depressed-cladding fiber. The adiabatic taper profile obtained during fabrication prevents the interference of other modes than HE11 and HE12 ones, which play the main role for the beating phenomenon and the filter response. The evolution of the fiber shapes during the pulling was modeled by two coupled partial differential equations, which relate the normalized cross-section area, and the axial velocity of the fiber elongation. These equations govern the mass and axial momentum conservation. The numerical results of the filter characteristics are in good accordance with the experimental ones. The filter was packaged in order to let it ready for using in optical communication bands. The characteristics are: free spectral range (FSR) of 6.19 nm, insertion loss bellow 0.5 dB, and isolation > 20 dB at C-band. Its transmission spectrum extends from 1200 to 1600 nm where the optical fiber core supports monomode transmission. Such characteristics may also be interesting to be applied in sensing applications. We show preliminary numerical results assuming a biconic taper embedded into a dielectric media, showing promising results for electro-optic sensing applications.

  2. Fabrication of biconical tapered optical fibers using hydrofluoric acid

    International Nuclear Information System (INIS)

    Haddock, Hong S.; Shankar, P.M.; Mutharasan, R.

    2003-01-01

    An easy to implement procedure for etching silica fibers in biconical form useful in sensing applications is described. A simple etching reactor was developed to obtain reproducible tapers of desired diameter and length. An approach for on-line monitoring of etching using a commonly used fluorometer is demonstrated. A mathematical model describing the light power transmission is proposed, and is validated using experimental data. The data and the model indicate that the diameter of the silica fiber decreases linearly with time with hydrofluoric acid (HF, 49.5% w/w) used as etchant at room temperature. The observed etching rate was 0.0023±0.00019 s -1 , which was repeatable using the procedure developed in this study. Method to arrest etching and subsequent preservation of the small diameter taper in mildly alkaline solution was found to be successful

  3. Biconically Tapered Fiber Optic Probes for Rapid Label-Free Immunoassays

    Directory of Open Access Journals (Sweden)

    John Miller

    2015-04-01

    Full Text Available We report use of U-shaped biconically tapered optical fibers (BTOF as probes for label-free immunoassays. The tapered regions of the sensors were functionalized by immobilization of immunoglobulin-G (Ig-G and tested for detection of anti-IgG at concentrations of 50 ng/mL to 50 µg/mL. Antibody-antigen reaction creates a biological nanolayer modifying the waveguide structure leading to a change in the sensor signal, which allows real-time monitoring. The kinetics of the antibody (mouse Ig-G-antigen (rabbit anti-mouse IgG reactions was studied. Hydrofluoric acid treatment makes the sensitive region thinner to enhance sensitivity, which we confirmed by experiments and simulations. The limit of detection for the sensor was estimated to be less than 50 ng/mL. Utilization of the rate of the sensor peak shift within the first few minutes of the antibody-antigen reaction is proposed as a rapid protein detection method.

  4. Experimental design rules for implementing biconically tapered single mode optical fibre displacement sensors

    Science.gov (United States)

    Arregui, Francisco J.; Matias, Ignacio R.; Bariain, Candido; Lopez-Amo, Manuel

    1998-06-01

    Tapered optical fibers are used to design couplers, wavelength division multiplexers, near field scanning optical microscopy, just to mention a few. Moreover, and due to its strong transmission dependence to external medium the tapered fiber may also be used to sense distinct parameters such as temperature, humidity, PH, etc. In this work bending effects in tapers are exploited to achieved displacement sensors and to present design rules for implementing these sensors according to the desired both range and sensitivity.

  5. Improved vibration sensor based on a biconical tapered singlemode fiber, using in-fiber Mach-Zehnder interferometer

    Science.gov (United States)

    Wonko, R.; Moś, J. E.; Stasiewicz, K. A.; Jaroszewicz, L. R.

    2017-05-01

    Optical fiber vibration sensors are an appropriate alternative for piezoelectric devices, which are electromagnetic sensitive to the external conditions. Most of the vibration sensors demonstrated in previous publications resist to different interferometers or Bragg's gratings. Such sensors require a long time of stabilization of an optical signal, because they are vulnerable to undesirable disturbance. In majority, time response of an optical sensor should be instantaneous, therefore we have proposed an in- line vibration sensing passive element based on a tapered fiber. Micrometer sized optical fiber tapers are attractive for many optical areas due to changes process of boundary conditions. Such phenomena allow for a sensitive detection of the modulation phase. Our experiment shows that a singlemode, adiabatic tapered fiber enables detecting an acoustic vibration. In this study, we report on Mach- Zehnder (MZ) interferometer as a vibration sensor which was composed of two 50/50 couplers at 1550 nm. In the reference arm we used a 4 meter singlemode optical fiber (SMF28), while in the arm under test we placed tapered optical fibers attached to a metal plate, put directly on speaker. Researches carried out on different tapered fibers which diameter of a taper waist was in the range from 5 μm to 25 μm, and each taper was characterized by optical losses less than 0,5 dB. The measured phase changes were over a frequency from 100 Hz to 1 kHz and an amplitude in the range from 100 mVpp to 1 Vpp. Although on account of a limited space we have showed only the results for 100 Hz. Nevertheless, experimental results show that this sensing system has a wide frequency response range from a few hertz to one of kilohertz, however for some conditions, a standard optical fiber showed better result.

  6. Narrow line-width Tm3+ doped double-clad silica fiber laser based on in-line cascade biconical tapers filter

    International Nuclear Information System (INIS)

    Tian, Y; Zhao, J Q; Wang, W; Wang, Y Z; Gao, W

    2010-01-01

    Narrow line-width 793 nm laser diode cladding pumped Tm 3+ doped double cladding silica fiber laser with in-line four concatenated tapers filter was reported for the first time to our knowledge. These cascade tapers located 3.6 cm from the output end of the fiber laser was fabricated by heating and stretching method. The taper's transmitted power response as a function of wavelength was described by using local mode coupling theory and successive tapers filter model. The wavelength filter function of the in-line cascade tapers in a linear cavity fiber laser was demonstrated, and the experimental result agreed with these theories. The maximum output laser power was 736 mW, corresponding to single peak of laser spectrum with narrow line-width of ∼ 60 pm

  7. Reconfiguration of the multiwavelength operation of optical fiber ring lasers by the modifiable intra-cavity induced losses of an in-fiber tip probe modal Michelson interferometer

    Science.gov (United States)

    Salceda-Delgado, G.; Martinez-Rios, A.; Sierra-Hernandez, J. M.; Rodríguez-Carreón, V. C.; Toral-Acosta, D.; Selvas-Aguilar, R.; Álvarez-Tamayo, R. I.; Castillo-Guzman, A. A.; Rojas-Laguna, R.

    2018-03-01

    A straightforward and versatile method for switching from single to different multiwavelength laser emission in ring cavity fiber lasers is proposed and demonstrated experimentally. The method is based on using the changeable interference pattern from an optical fiber modal Michelson interferometer as a wavelength selective filter into the ring cavity laser. The interferometer is constructed using a bi-conical tapered fiber and a single-mode fiber segment, with these being spliced together to form an optical fiber tip probe. When the length of the single-mode fiber piece is modified, the phase difference between the interfering modes of the interferometer causes a change in the interferometer free spectral range. As a consequence, the laser intra-cavity losses lead to gain competition, which allows us to adjust the number of simultaneously generated laser lines. A multiwavelength reconfiguration of the laser from one up to a maximum of eight emission lines was obtained, with a maximum SNR of around 47 dBm.

  8. Bicone vacuum chamber for ISR intersection

    CERN Multimedia

    1975-01-01

    This is one of the bicone chambers made of titanium for experiment R 702. The central corrugated part had a very thin titanium wall (0.28 mm). The first of these chambers collapsed in its central part when baked at 300 C (August 1975). After an intensive effort to develop better quality and reproducible welds for this special material, the ISR workshop was able to build two new chambers of this type. One of them was installed at I 7 for R 702 in 1976 and worked perfectly. It was at that time the most "transparent" intersection vacuum chamber. See also 7609219, 7609221.

  9. Single frequency intracavity SRO

    DEFF Research Database (Denmark)

    Abitan, Haim; Buchhave, Preben

    2000-01-01

    Summary form only given. A single resonance optical parametric oscillator (SRO) is inserted intracavity to a CW high power, single frequency, and ring Nd:YVO4 laser. We obtain a stable single frequency CW SRO with output at 1.7-1.9 μm (idler) and a resonating signal at 2.3-2.6 μm. The behavior...

  10. Adiabatic tapered optical fiber fabrication in two step etching

    Science.gov (United States)

    Chenari, Z.; Latifi, H.; Ghamari, S.; Hashemi, R. S.; Doroodmand, F.

    2016-01-01

    A two-step etching method using HF acid and Buffered HF is proposed to fabricate adiabatic biconical optical fiber tapers. Due to the fact that the etching rate in second step is almost 3 times slower than the previous droplet etching method, terminating the fabrication process is controllable enough to achieve a desirable fiber diameter. By monitoring transmitted spectrum, final diameter and adiabaticity of tapers are deduced. Tapers with losses about 0.3 dB in air and 4.2 dB in water are produced. The biconical fiber taper fabricated using this method is used to excite whispering gallery modes (WGMs) on a microsphere surface in an aquatic environment. So that they are suitable to be used in applications like WGM biosensors.

  11. Microdroplet-etched highly birefringent low-loss fiber tapers.

    Science.gov (United States)

    Mikkelsen, Jared C; Poon, Joyce K S

    2012-07-01

    We use hydrofluoric acid microdroplets to directly etch highly birefringent biconical fiber tapers from standard single-mode fibers. The fiber tapers have micrometer-sized cross sections, which are controlled by the etching condition. The characteristic teardrop cross section leads to a high group birefringence of B(G)≈0.017 and insertion losses <0.7 dB over waist lengths of about 2.1 mm.

  12. Intracavity vortex beam generation

    Science.gov (United States)

    Naidoo, Darryl; Aït-Ameur, Kamel; Forbes, Andrew

    2011-10-01

    In this paper we explore vortex beams and in particular the generation of single LG0l modes and superpositions thereof. Vortex beams carry orbital angular momentum (OAM) and this intrinsic property makes them prevalent in transferring this OAM to matter and to be used in quantum information processing. We explore an extra-cavity and intra-cavity approach in LG0l mode generation respectively. The outputs of a Porro-prism resonator are represented by "petals" and we show that through a full modal decomposition, the "petal" fields are a superposition of two LG0l modes.

  13. Characteristics of the wire biconical antenna used for EMC measurements

    Science.gov (United States)

    Austin, Brian A.; Fourie, Andre P. C.

    1991-08-01

    The characteristics of a wire biconical antenna that determine its antenna factor were computed by using the method of moments code NEC-2. A fairly extensive validation exercise was conducted from which a suitable computer model was derived. The input impedance, gain, and radiation patterns of the antenna were computed for special cases where the biconical antenna is used above a conducting ground plane for open-field EMC (electromagnetic compatibility) testing. The effects of height above the ground plane and polarization of the antenna on these parameters were found and the antenna factor was corrected for them. The current distribution along the antenna elements was also examined, and it was found that significant pattern distortion can occur at some frequencies when a horizontal wire biconical antenna is used close to the ground. These results will allow this broadband antenna to be used with confidence in applications where previously only resonant dipoles were specified.

  14. Adiabatic tapered optical fiber fabrication for exciting whispering gallery modes in microcavities

    Science.gov (United States)

    Chenari, Z.; Latifi, H.; Hashemi, R. S.; Doroudmand, F.

    2014-05-01

    This article demonstrates an investigation and analysis of a tapered fiber fabrication using an etchant droplet method. To achieve precise control on process, a two-step etching method is proposed (using 48% concentration of HF acid and Buffered HF) which results in low-loss adiabatic tapered fiber. A spectrum analysis monitoring in addition to a microscopy system was used to verify the etching progress. Tapers with losses less than 0.4 dB in air and 4.5 dB in water are demonstrated. A biconical fiber taper fabricated using this method was used to excite the WGMs on a microsphere surface in aquatic environment.

  15. Bi-cone vacuum chamber in the ISR

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The "bi-cone" vacuum chamber in ISR intersection I-7, for experiment R702. Made from 0.28 mm thick titanium, it was at its time the most transparent chamber ever built. Ian Wilson is standing next to the chamber. See also 7609219.

  16. Sinking and fit of abutment of locking taper implant system

    Science.gov (United States)

    Moon, Seung-Jin; Kim, Hee-Jung; Son, Mee-Kyoung

    2009-01-01

    STATEMENT OF PROBLEM Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE In this study, Bicon® Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS 10 Bicon® implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS It was evident, that the amount of abutment sinking in Bicon® Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at 0.45 ± 0.09 mm. CONCLUSION Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location. PMID:21165262

  17. Adaptable Optical Fiber Displacement-Curvature Sensor Based on a Modal Michelson Interferometer with a Tapered Single Mode Fiber.

    Science.gov (United States)

    Salceda-Delgado, G; Martinez-Rios, A; Selvas-Aguilar, R; Álvarez-Tamayo, R I; Castillo-Guzman, A; Ibarra-Escamilla, B; Durán-Ramírez, V M; Enriquez-Gomez, L F

    2017-06-02

    A compact, highly sensitive optical fiber displacement and curvature radius sensor is presented. The device consists of an adiabatic bi-conical fused fiber taper spliced to a single-mode fiber (SMF) segment with a flat face end. The bi-conical taper structure acts as a modal coupling device between core and cladding modes for the SMF segment. When the bi-conical taper is bent by an axial displacement, the symmetrical bi-conical shape of the tapered structure is stressed, causing a change in the refractive index profile which becomes asymmetric. As a result, the taper adiabaticity is lost, and interference between modes appears. As the bending increases, a small change in the fringe visibility and a wavelength shift on the periodical reflection spectrum of the in-fiber interferometer is produced. The displacement sensitivity and the spectral periodicity of the device can be adjusted by the proper selection of the SMF length. Sensitivities from around 1.93 to 3.4 nm/mm were obtained for SMF length between 7.5 and 12.5 cm. Both sensor interrogations, wavelength shift and visibility contrast, can be used to measure displacement and curvature radius magnitudes.

  18. Parametric fitting of corneal height data to a biconic surface.

    Science.gov (United States)

    Janunts, Edgar; Kannengießer, Marc; Langenbucher, Achim

    2015-03-01

    As the average corneal shape can effectively be approximated by a conic section, a determination of the corneal shape by biconic parameters is desired. The purpose of the paper is to introduce a straightforward mathematical approach for extracting clinically relevant parameters of corneal surface, such as radii of curvature and conic constants for principle meridians and astigmatism. A general description for modeling the ocular surfaces in a biconic form is given, based on which an implicit parametric surface fitting algorithm is introduced. The solution of the biconic fitting is obtained by a two sequential least squares optimization approach with constrains. The data input can be raw information from any corneal topographer with not necessarily a uniform data distribution. Various simulated and clinical data are studied including surfaces with rotationally symmetric and non-symmetric geometries. The clinical data was obtained from the Pentacam (Oculus) for the patient having undergone a refractive surgery. A sub-micrometer fitting accuracy was obtained for all simulated surfaces: 0,08 μm RMS fitting error at max for rotationally symmetric and 0,125 μm for non-symmetric surfaces. The astigmatism was recovered in a sub-minutes resolution. The equality in rotational symmetric and the superiority in non-symmetric surfaces of the presented model over the widely used quadric fitting model is shown. The introduced biconic surface fitting algorithm is able to recover the apical radii of curvature and conic constants in principle meridians. This methodology could be a platform for advanced IOL calculations and enhanced contact lens fitting. Copyright © 2014. Published by Elsevier GmbH.

  19. Intracavity Laser Photoacoustic Spectrometer with High Sensitivity

    International Nuclear Information System (INIS)

    Mitrayana; Muslim; Wasono, M.A.J.

    2002-01-01

    A photo acoustic spectrometer set-up has been upgraded from an extra cavity into an intracavity configuration using a sealed-off CO 2 laser as the spectrometer's radiation source. The detection level of the upgrade Intracavity Photoacoustic Spectrometer (IPS) reached (200 ± 50) ppt for C 2 H 4 and (20 ± 5) ppt for SF 6 with response time (6.6 ± 0.2) s. (author)

  20. TEr azimuthal modes for a biconic transmission line in the small-gap limit

    International Nuclear Information System (INIS)

    Johnson, W.A.; Mendel, C.W. Jr.; Seidel, D.B.

    1992-01-01

    Azimuthally asymmetric modes in a biconic transmission line with a small-gap angle may be approximated by ''transmission-line-like'' modes. It is shown that the errors in these approximations are second order in the gap angle and approximate error bounds are provided. As an example demonstrating the application of this analysis in biconic structures, an analysis to characterize of the electromagnetic waves in the vacuum feed of the Particle Beam Fusion Accelerator II is provided

  1. Dynamical regimes and intracavity propagation delay in external ...

    Indian Academy of Sciences (India)

    E JAYAPRASATH

    MS received 14 November 2016; revised 3 May 2017; accepted 1 June 2017; published online 31 October 2017. Abstract. Intracavity ... In order to implement secure optical communication, .... Dependence of intracavity propagation delay on.

  2. The Toby Jug nebula (IC 2220): a bipolar and biconical nebula

    International Nuclear Information System (INIS)

    Perkins, H.G.; King, D.J.; Scarrott, S.M.

    1981-01-01

    An optical linear polarization map of IC 2220, the nebula surrounding the cool red giant HD 65750, is presented. The nebula appears to be bipolar and biconical in structure. The mass of the nebula is estimated to be 0.01 solar mass and is consistent with the nebula being formed from the current mass loss stage of the central star. (author)

  3. Tapered waveguide InGaAs/InGaAsP multiple-quantum-well lasers

    International Nuclear Information System (INIS)

    Koch, T.L.; Koren, U.; Eisentein, G.; Young, M.G.; Oron, M.; Giles, C.R.; Miller, B.I.

    1990-01-01

    The authors propose and demonstrate the application of ultra-thin etch-stop fabrication techniques to adiabatically expand the vertical optical mode size in 1.5 μm InGaAs/InGaAsP MQW lasers using a tapered-core passive intracavity waveguide structure. They achieve 30% differential quantum efficiency out the tapered facet, far-field FWHM of ∼ 12 degrees, and a butt-coupling efficiency into a cleaved fiber of - 4.2 dB, with - 1 dB alignment tolerances of ∼ ± 3 μM

  4. Efficient yellow beam generation by intracavity sum frequency ...

    Indian Academy of Sciences (India)

    2014-02-06

    Feb 6, 2014 ... We present our studies on dual wavelength operation using a single Nd:YVO4 crystal and its intracavity sum frequency generation by considering the influence of the thermal lensing effect on the performance of the laser. A KTP crystal cut for type-II phase matching was used for intracavity sum frequency ...

  5. Lasers with intra-cavity phase elements

    Science.gov (United States)

    Gulses, A. Alkan; Kurtz, Russell; Islas, Gabriel; Anisimov, Igor

    2018-02-01

    Conventional laser resonators yield multimodal output, especially at high powers and short cavity lengths. Since highorder modes exhibit large divergence, it is desirable to suppress them to improve laser quality. Traditionally, such modal discriminations can be achieved by simple apertures that provide absorptive loss for large diameter modes, while allowing the lower orders, such as the fundamental Gaussian, to pass through. However, modal discrimination may not be sufficient for short-cavity lasers, resulting in multimodal operation as well as power loss and overheating in the absorptive part of the aperture. In research to improve laser mode control with minimal energy loss, systematic experiments have been executed using phase-only elements. These were composed of an intra-cavity step function and a diffractive out-coupler made of a computer-generated hologram. The platform was a 15-cm long solid-state laser that employs a neodymium-doped yttrium orthovanadate crystal rod, producing 1064 nm multimodal laser output. The intra-cavity phase elements (PEs) were shown to be highly effective in obtaining beams with reduced M-squared values and increased output powers, yielding improved values of radiance. The utilization of more sophisticated diffractive elements is promising for more difficult laser systems.

  6. Tapered structure construction

    Science.gov (United States)

    Smith, Eric D.; Takata, Rosalind K.; Slocum, Alexander H.; Nayfeh, Samir A.

    2016-04-05

    Feeding stock used to form a tapered structure into a curving device such that each point on the stock undergoes rotational motion about a peak location of the tapered structure; and the stock meets a predecessor portion of stock along one or more adjacent edges.

  7. Bi-cone system of concentric, explosion-induced D-T compression

    International Nuclear Information System (INIS)

    Kaliski, S.

    1978-01-01

    The concept and the assessment is given of the neutron yield for the bi-cone cumulative system with the aid whereof a spherical deuterized-polyethylene shell has been imploded into D-T (D) gas. The assessment of neutron yield within the limits of 10 10 - 5 x 10 10 has been obtained for D-T gas as well as 2 x 10 8 - 10 9 for D-gas. The assessments are approximate with an accuracy of an order of magnitude. (author)

  8. 14C analysis via intracavity optogalvanic spectroscopy

    International Nuclear Information System (INIS)

    Murnick, Daniel; Dogru, Ozgur; Ilkmen, Erhan

    2010-01-01

    A new ultra sensitive laser-based analytical technique, intracavity optogalvanic spectroscopy (ICOGS), allowing extremely high sensitivity for detection of 14 C-labeled carbon dioxide has recently been demonstrated. Capable of replacing accelerator mass spectrometers (AMS) for many applications, the technique quantifies zeptomoles of 14 C in sub micromole CO 2 samples. Based on the specificity of narrow laser resonances coupled with the sensitivity provided by standing waves in an optical cavity, and detection via impedance variations, limits of detection near 10 -1514 C/ 12 C ratios have been obtained with theoretical limits much lower. Using a 15 W 14 CO 2 laser, a linear calibration with samples from 5 x 10 -15 to >1.5 x 10 -12 in 14 C/ 12 C ratios, as determined by AMS, was demonstrated. Calibration becomes non-linear over larger concentration ranges due to interactions between CO 2 and buffer gas, laser saturation effects and changes in equilibration time constants. The instrument is small (table top), low maintenance and can be coupled to GC or LC input. The method can also be applied to detection of other trace entities. Possible applications include microdosing studies in drug development, individualized sub-therapeutic tests of drug metabolism, carbon dating and real time monitoring of atmospheric radiocarbon.

  9. Numerical modelling of passively Q-switched intracavity Raman lasers

    International Nuclear Information System (INIS)

    Ding Shuanghong; Zhang Xingyu; Wang Qingpu; Zhang Jun; Wang Shumei; Liu Yuru; Zhang Xuehui

    2007-01-01

    Assuming intracavity photon densities to be of Gaussian spatial distributions, the space-dependent rate equations of passively Q-switched intracavity Raman lasers are deduced for the first time for the pumping beams of Gaussian and top-head spatial distributions, respectively. The new rate equations are normalized and solved numerically to investigate the influences of the normalized initial population inversion density, normalized Raman gain coefficient, saturable absorber parameter, beam size ratio of pump to fundamental laser and loss ratio of the first Stokes to fundamental laser on the pulse parameters of the first Stokes. The results of the Gaussian and top-head pumpings show similar trends despite some discrepancies. The new theories and numerical results will help design passively Q-switched intracavity Raman lasers of high performance

  10. Trace gas detection by laser intracavity photothermal spectroscopy

    International Nuclear Information System (INIS)

    Fung, K.H.; Lin, H.h.

    1986-01-01

    A novel laser intracavity photothermal detector is described. In this scheme, sample absorption of the pump laser power takes place within the cavity of a probe He-Ne laser causing modulation in the gain and in turn the output power. Comparison of this intracavity detector with two other photothermal techniques, namely, phase fluctuation optical heterodyne spectroscopy and thermal beam deflection, is made in terms of practicality and sensitivity. For in situ measurements, sensitivity of 0.5 x 10 -7 cm -1 for a probe length of 3 cm has been achieved

  11. The wild tapered block bootstrap

    DEFF Research Database (Denmark)

    Hounyo, Ulrich

    In this paper, a new resampling procedure, called the wild tapered block bootstrap, is introduced as a means of calculating standard errors of estimators and constructing confidence regions for parameters based on dependent heterogeneous data. The method consists in tapering each overlapping block...... of the series first, the applying the standard wild bootstrap for independent and heteroscedastic distrbuted observations to overlapping tapered blocks in an appropriate way. Its perserves the favorable bias and mean squared error properties of the tapered block bootstrap, which is the state-of-the-art block......-order asymptotic validity of the tapered block bootstrap as well as the wild tapered block bootstrap approximation to the actual distribution of the sample mean is also established when data are assumed to satisfy a near epoch dependent condition. The consistency of the bootstrap variance estimator for the sample...

  12. Intra-cavity generation of superpositions of Laguerre-Gaussian beams

    CSIR Research Space (South Africa)

    Naidoo, Darryl

    2012-01-01

    Full Text Available In this paper we demonstrate experimentally the intra-cavity generation of a coherent superposition of Laguerre–Gaussian modes of zero radial order but opposite azimuthal order. The superposition is created with a simple intra-cavity stop...

  13. Optimization of an intracavity Q-switched solid-state second order Raman laser

    Science.gov (United States)

    Chen, Zhiqiong; Fu, Xihong; Peng, Hangyu; Zhang, Jun; Qin, Li; Ning, Yongqiang

    2017-01-01

    In this paper, the model of an intracavity Q-switched second order Raman laser is established, the characteristics of the output 2nd Stokes are simulated. The dynamic balance mechanism among intracavity conversion rates of stimulated emission, first order Raman and second order Raman is obtained. Finally, optimization solutions for increasing output 2nd Stokes pulse energy are proposed.

  14. Tapered undulators for SASE FELs

    CERN Document Server

    Fawley, W M; Vinokurov, N A

    2002-01-01

    We discuss the use of tapered undulators to enhance the performance of free-electron lasers (FELs) based upon self-amplified spontaneous emission, where the radiation tends to have a relatively broad bandwidth and limited temporal coherence. Using the polychromatic FEL simulation code GINGER, we numerically demonstrate the effectiveness of tapered undulators for parameters corresponding to the Argonne low-energy undulator test line FEL and the proposed linac coherent light source.

  15. Theory of tapered laser cooling

    International Nuclear Information System (INIS)

    Okamoto, Hiromi; Wei, J.

    1998-01-01

    A theory of tapered laser cooling for fast circulating ion beams in a storage ring is constructed. The authors describe the fundamentals of this new cooling scheme, emphasizing that it might be the most promising way to beam crystallization. The cooling rates are analytically evaluated to study the ideal operating condition. They discuss the physical implication of the tapering factor of cooling laser, and show how to determine its optimum value. Molecular dynamics method is employed to demonstrate the validity of the present theory

  16. Controlling nanowire emission profile using conical taper

    DEFF Research Database (Denmark)

    Gregersen, Niels; Nielsen, Torben Roland; Mørk, Jesper

    2008-01-01

    The influence of a conical taper on nanowire light emission is studied. For nanowires with divergent output beams, the introduction of tapers improves the emission profile and increase the collection efficiency of the detection optics....

  17. Very short intracavity directional coupler for high-speed communication

    Science.gov (United States)

    Griffel, Giora

    1993-07-01

    We propose a novel intracavity modulator/switch that consists of a directional-coupler located inside a Fabry-Perot cavity. The back mirror of the cavity has a unit reflectivity so that both input and output signals are at the same side. In this way we obtain a two-port, single side element, with coupling length of 83.5 μm, which is the shortest modulation coupler proposed so far. The upper frequency limit due to photon lifetime is 275 GHz, which is well over the bandwidth constraints of microwave lumped structures. A unified approach for the analysis of this device and other similar structures is presented and discussed.

  18. Intracavity Faraday modulation spectroscopy (INFAMOS): A tool for radical detection

    Science.gov (United States)

    Gianella, Michele; Pinto, Tomas H. P.; Wu, Xia; Ritchie, Grant A. D.

    2017-08-01

    We present the intra-cavity Faraday modulation spectroscopy technique, whereby optical feedback cavity-enhanced spectroscopy is coupled with Faraday modulation spectroscopy to greatly enhance the interaction path length of a laser beam with a paramagnetic sample in a magnetic field. We describe a first prototype based upon a cw quantum cascade laser targeting a selection of fundamental rovibrational R-branch transitions of nitric oxide (1890 cm-1), consisting of a linear cavity (finesse F =6300 ) and a water-cooled solenoid. We demonstrate a minimum detectable Verdet constant of Vmin=4.7 ×10-14 rad cm-1 G-1 H z-1/2 (at SNR = 1), corresponding to a single-pass rotation angle of 1.6 ×10-10 rad Hz-1/2 and a limit of detection of 0.21 ppbv Hz-1/2 NO.

  19. Intracavity Faraday modulation spectroscopy (INFAMOS): A tool for radical detection.

    Science.gov (United States)

    Gianella, Michele; Pinto, Tomas H P; Wu, Xia; Ritchie, Grant A D

    2017-08-07

    We present the intra-cavity Faraday modulation spectroscopy technique, whereby optical feedback cavity-enhanced spectroscopy is coupled with Faraday modulation spectroscopy to greatly enhance the interaction path length of a laser beam with a paramagnetic sample in a magnetic field. We describe a first prototype based upon a cw quantum cascade laser targeting a selection of fundamental rovibrational R-branch transitions of nitric oxide (1890 cm -1 ), consisting of a linear cavity (finesse F=6300) and a water-cooled solenoid. We demonstrate a minimum detectable Verdet constant of V min =4.7×10 -14  rad cm -1  G -1  Hz -1/2 (at SNR = 1), corresponding to a single-pass rotation angle of 1.6×10 -10  rad Hz -1/2 and a limit of detection of 0.21 ppbv Hz -1/2 NO.

  20. Heat-transfer distributions on biconics at incidence in hypersonic-hypervelocity He, N2, air, and CO2 flows

    Science.gov (United States)

    Miller, C. G.; Micol, J. R.; Gnoffo, P. A.; Wilder, S.E.

    1983-01-01

    Laminar heat-transfer rates were measured on spherically blunted, 13 degrees/F degrees on-axis and bent biconics (fore cone bent 7 degrees upward relative to aft cone) at hypersonic-hypervelocity flow conditions in the Langley Expansion Tube. Freestream velocities from 4.5 to 6.9 km/sec and Mach numbers from 6 to 9 were generated using helium, nitrogen, air, and carbon dioxide test gases, resulting in normal shock density ratios from 4 to 19. Angle of attack, referenced to the axis of the aft cone, was varied from zero to 20 degrees in 4 degree increments. The effect of nose bend, angle of attack, and real-gas phenomena on heating distributions are presented along with comparisons of measurement to prediction from a code which solves the three-dimensional 'parabolized Navier-Stokes' equations.

  1. An In-depth Chandra ACIS View Of The Circumnuclear Region Of NGC 4151: The Jet, The Biconical Outflow, And A Leaky Torus

    Science.gov (United States)

    Wang, Junfeng; Fabbiano, G.; Elvis, M.; Risaliti, G.; Karovska, M.; Zezas, A.; Mundell, C. G.

    2011-05-01

    We report on the imaging analysis of 200 ks Chandra ACIS-S observations of the nearby Seyfert 1 galaxy NGC 4151. Structured soft X-ray emission is observed to extend from 30 pc to 1.5 kpc. We find strong evidence for jet-gas cloud interaction in the inner 150 pc region, confirming our previous HRC results. Self-consistent photoionization models provide good descriptions of the spectra of the optical bi-cone, supporting the dominant role of nuclear photoionization. Presence of both low and high ionization spectral components and extended emission in the X-ray image perpendicular to the bi-cone indicates leakage of nuclear ionization. Using spatially resolved features, we estimate the kinematic power of the outflow in NGC 4151 to be 0.3% of its bolometric luminosity. This work is supported by NASA grant GO8-9101X and GO1-12009X.

  2. Intracavity doubling of CW Ti:sapphire laser to 392.5 nm using BiBO-crystal

    DEFF Research Database (Denmark)

    Mortensen, Jesper Liltorp; Thorhauge, Morten; Tidemand-Lichtenberg, Peter

    2005-01-01

    In this work we present results obtained for intra-cavity frequency-doubling of a 785 nm CW Ti:sapphire laser utilising BiBO as the non-linear crystal. Intracavity doubling offers several advantages compared to extra-cavity doubling, such as no need to couple to an external resonance cavity...

  3. Investigation of a diode-pumped intracavity optical parametric oscillator in pulsed and continuous wave operation

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Skettrup, Torben; Balle-Petersen, O.

    2001-01-01

    Summary form only given. CW and pulsed compact tunable laser sources in the infrared have widespread scientific, medical and industrial applications. Such a laser source can be obtained by use of a diode-pumped intracavity optical parametric oscillator (IOPO). We report on a IOPO based on a Yb......:YAG laser incorporating a periodically poled LiNbO3 (PPLN) crystal inside the laser cavity to take advantage of the high circulating intracavity field. The Yb:YAG crystal is pumped by a reliable 940 nm fibre-coupled diode laser. The IOPO consists of a Yb:YAG crystal coated for HR at 1030 nm, an intracavity...... lens to generate a beam waist in the PPLN crystal, a dichroic mirror to separate the laser and signal fields and two end mirrors...

  4. Process of coping with intracavity radiation treatment for gynecologic cancer

    International Nuclear Information System (INIS)

    Nail, L.M.D.

    1985-01-01

    The purpose of this study was to describe the process of coping with the experience of receiving intracavity radiation treatment (ICR) for gynecologic cancer. Data were collected on the outcomes of coping, emotion (Profile of Mood States) and level of function (Sickness Impact Profile), and symptom severity and upset the evening before, during, the day after, and 1 to 2 weeks after treatment. The subjects (N = 28) had a mean age of 52 years, 39% were employed full-time, 56% had occupations as manual workers, 57% had completed 12 or more years of education, and 68% were married or widowed. The treatment required the subjects to be hospitalized on complete bedrest with radiation precautions for an average of 48 hours. Intrauterine devices were used to treat 18 subjects and vaginal applications were used to treat 10 subjects. Negative mood and level of disruption in function were generally low. Repeated measures ANOVA showed no change in negative mood over time while the change in function was attributable to the increase in disruption during treatment. Utilization of affective coping strategies and problem-oriented coping strategies was positively correlated with negative mood and disruption in function over the points of measurement. The results indicate that subjects tolerated ICR well and rapidly resumed usual function following discharge from the hospital, despite the persistence of some symptoms 1 to 2 weeks after treatment. The positive association between the utilization of coping strategies and negative outcomes of coping suggests a need to examine the measurement of coping strategies and consider the possibility that these actions represent a response to a stressful situation rather than a method of dealing with the situation

  5. Structural and dynamic analysis of an ultra short intracavity directional coupler

    Science.gov (United States)

    Gravé, Ilan; Griffel, Giora; Daou, Youssef; Golan, Gadi

    1997-01-01

    A recently proposed intracavity directional coupler is analysed. Exact analytic expressions for important parameters such as the transmission ratio, the coupling length, and the photon lifetime are given. We show that by controlling the mirror reflectivities of the cavity, it is theoretically possible to reduce the coupling length to a zero limit. The photon lifetime, which governs the dynamic properties of the structure, sets an upper frequency limit of a few hundreds of GHz, which is well over the bandwidth limitation of microwave lumped or travelling wave electrodes. This novel family of intracavity couplers has important applications in the realization of integrated optics circuits for high-speed computing, data processing, and communication.

  6. Implementation of intra-cavity beam shaping technique to enhance pump efficiency

    CSIR Research Space (South Africa)

    Litvin, IA

    2012-02-01

    Full Text Available In this work the author proposes an implementation of a new intra-cavity beam shaping technique to vary the intensity distribution of the fundamental mode in a resonator cavity while maintaining a constant intensity distribution at the output...

  7. Intracavity OptoGalvanic Spectroscopy Not Suitable for Ambient Level Radiocarbon Detection

    NARCIS (Netherlands)

    Paul, Dipayan; Meijer, Harro

    2015-01-01

    IntraCavity OptoGalvanic Spectroscopy as a radiocarbon detection technique was first reported by the Murnick group at Rutgers University, Newark, NJ, in 2008. This technique for radiocarbon detection was presented with tremendous potentials for applications in various fields of research.

  8. Intra-cavity metamorphosis of a Gaussian beam to flat-top distribution

    CSIR Research Space (South Africa)

    Naidoo, Darryl

    2014-02-01

    Full Text Available We explore an intra-cavity beam shaping approach to generate a Gaussian distribution by the metamorphosis of a Gaussian beam into a flat-top distribution on opposing mirrors. The concept is tested external to the cavity through the use of two...

  9. Intra-cavity decomposition of a dual-directional laser beam

    CSIR Research Space (South Africa)

    Naidoo, Darryl

    2011-01-01

    Full Text Available A method of decomposing a dual-directional laser beam into a forward propagating field and a backward propagating field for an apertured plano-concave cavity is presented. An intra-cavity aperture is a simple method of laser beam shaping as higher...

  10. Nanofocusing in a tapered graphene plasmonic waveguide

    DEFF Research Database (Denmark)

    Dai, Yunyun; Zhu, Xiaolong; Mortensen, N. Asger

    2015-01-01

    Gated or doped graphene can support plasmons making it a promising plasmonic material in the terahertz regime. Here, we show numerically that in a tapered graphene plasmonic waveguide mid- and far-infrared light can be focused in nanometer scales, far beyond the diffraction limit. The underlying...... physics lies in that when propagating along the direction towards the tip both the group and phase velocities of the plasmons supported by the tapered graphene waveguide are reduced accordingly, eventually leading to nanofocusing at the tip with a huge enhancement of optical fields. The nanofocusing...... of optical fields in tapered graphene plasmonic waveguides could be potentially exploited in the enhancement of light–matter interactions....

  11. Fabrication of longitudinally arbitrary shaped fiber tapers

    Science.gov (United States)

    Nold, J.; Plötner, M.; Böhme, S.; Sattler, B.; deVries, O.; Schreiber, T.; Eberhardt, R.; Tünnermann, A.

    2018-02-01

    We present our current results on the fabrication of arbitrary shaped fiber tapers on our tapering rig using a CO2-laser as heat source. Single mode excitation of multimode fibers as well as changing the fiber geometry in an LPG-like fashion is presented. It is shown that this setup allows for reproducible fabrication of single-mode excitation tapers to extract the fundamental mode (M2 < 1.1) from a 30 μm core having an NA of 0.09.

  12. Tapering strategies in elite British endurance runners.

    Science.gov (United States)

    Spilsbury, Kate L; Fudge, Barry W; Ingham, Stephen A; Faulkner, Steve H; Nimmo, Myra A

    2015-01-01

    The aim of the study was to explore pre-competition training practices of elite endurance runners. Training details from elite British middle distance (MD; 800 m and 1500 m), long distance (LD; 3000 m steeplechase to 10,000 m) and marathon (MAR) runners were collected by survey for 7 days in a regular training (RT) phase and throughout a pre-competition taper. Taper duration was [median (interquartile range)] 6 (3) days in MD, 6 (1) days in LD and 14 (8) days in MAR runners. Continuous running volume was reduced to 70 (16)%, 71 (24)% and 53 (12)% of regular levels in MD, LD and MAR runners, respectively (P training (MD; 53 (45)%, LD; 67 (23)%, MAR; 64 (34)%, P training intensity was above race speed in LD and MAR runners (112 (27)% and 114 (3)%, respectively, P training undertaken prior to the taper in elite endurance runners is predictive of the tapering strategy implemented before competition.

  13. Vacuum chamber 'bicone'

    CERN Multimedia

    1977-01-01

    This chamber is now in the National Museum of History and Technology, Smithsonian Institution, Washington, DC, USA, where it was exposed in an exhibit on the History of High Energy Accelerators (1977).

  14. Optofluidic intracavity spectroscopy for spatially, temperature, and wavelength dependent refractometry

    Science.gov (United States)

    Kindt, Joel D.

    A microfluidic refractometer was designed based on previous optofluidic intracavity spectroscopy (OFIS) chips utilized to distinguish healthy and cancerous cells. The optofluidic cavity is realized by adding high reflectivity dielectric mirrors to the top and bottom of a microfluidic channel. This creates a plane-plane Fabry-Perot optical cavity in which the resonant wavelengths are highly dependent on the optical path length inside the cavity. Refractometry is a useful method to determine the nature of fluids, including the concentration of a solute in a solvent as well as the temperature of the fluid. Advantages of microfluidic systems are the easy integration with lab-on-chip devices and the need for only small volumes of fluid. The unique abilities of the microfluidic refractometer in this thesis include its spatial, temperature, and wavelength dependence. Spatial dependence of the transmission spectrum is inherent through a spatial filtering process implemented with an optical fiber and microscope objective. A sequence of experimental observations guided the change from using the OFIS chip as a cell discrimination device to a complimentary refractometer. First, it was noted the electrode structure within the microfluidic channel, designed to trap and manipulate biological cells with dielectrophoretic (DEP) forces, caused the resonant wavelengths to blue-shift when the electrodes were energized. This phenomenon is consistent with the negative dn/dT property of water and water-based solutions. Next, it was necessary to develop a method to separate the optical path length into physical path length and refractive index. Air holes were placed near the microfluidic channel to exclusively measure the cavity length with the known refractive index of air. The cavity length was then interpolated across the microfluidic channel, allowing any mechanical changes to be taken into account. After the separation of physical path length and refractive index, it was of interest

  15. Simulation of the dynamics of a multimode bipolarisation class B laser with intracavity frequency doubling

    International Nuclear Information System (INIS)

    Khandokhin, Pavel A

    2006-01-01

    A model of a multimode bipolarisation solid-state laser with intracavity frequency doubling is developed. The interaction of different longitudinal modes is described within the framework of rate-equation approximation while the interaction of each pair of orthogonally polarised modes with identical longitudinal indices is described taking into account the phase-sensitive interaction of these modes. Comparison with the experimental data is performed. (dinamics processes in lasers)

  16. Intracavity OptoGalvanic Spectroscopy not suitable for ambient level radiocarbon detection.

    Science.gov (United States)

    Paul, Dipayan; Meijer, Harro A J

    2015-09-01

    IntraCavity OptoGalvanic Spectroscopy as a radiocarbon detection technique was first reported by the Murnick group at Rutgers University, Newark, NJ, in 2008. This technique for radiocarbon detection was presented with tremendous potentials for applications in various fields of research. Significantly cheaper, this technique was portrayed as a possible complementary technique to the more expensive and complex accelerator mass spectrometry. Several groups around the world started developing this technique for various radiocarbon related applications. The IntraCavity OptoGalvanic Spectroscopy setup at the University of Groningen was constructed in 2012 in close collaboration with the Murnick group for exploring possible applications in the fields of radiocarbon dating and atmospheric monitoring. In this paper we describe a systematic evaluation of the IntraCavity OptoGalvanic Spectroscopy setup at Groningen for radiocarbon detection. Since the IntraCavity OptoGalvanic Spectroscopy setup was strictly planned for dating and atmospheric monitoring purposes, all the initial experiments were performed with CO2 samples containing contemporary levels and highly depleted levels of radiocarbon. Because of recurring failures in differentiating the two CO2 samples, with the radiocarbon concentration 3 orders of magnitude apart, CO2 samples containing elevated levels of radiocarbon were prepared in-house and experimented with. All results obtained thus far at Groningen are in sharp contrast to the results published by the Murnick group and rather support the results put forward by the Salehpour group at Uppsala University. From our extensive test work, we must conclude that the method is unsuited for ambient level radiocarbon measurements, and even highly enriched CO2 samples yield insignificant signal.

  17. Implementation of bright six-partite entanglement by coupled intracavity sum frequency generation

    Science.gov (United States)

    Wang, Junfeng; Liu, Le; Liu, Yuzhu; Zhang, Yanan; Wu, Hongyan; Gong, Chengxuan; Zhang, Ruofan; Zhang, Houyuan; Fan, JingYu

    2018-04-01

    Bright six-partite continuous-variable (CV) entanglement generated by the coupled intracavity sum frequency generation is investigated. The entanglement characteristics of reflected pump fields and the output sum frequency fields are discussed theoretically in symmetric and asymmetric cases by applying van Loock and Furusawa criteria for multipartite CV entanglement. Such compact tunable multipartite CV entanglement, generated from an experimentally feasible coupled system, could be used in integrated quantum communication and networks.

  18. Rotational flow in tapered slab rocket motors

    Science.gov (United States)

    Saad, Tony; Sams, Oliver C.; Majdalani, Joseph

    2006-10-01

    Internal flow modeling is a requisite for obtaining critical parameters in the design and fabrication of modern solid rocket motors. In this work, the analytical formulation of internal flows particular to motors with tapered sidewalls is pursued. The analysis employs the vorticity-streamfunction approach to treat this problem assuming steady, incompressible, inviscid, and nonreactive flow conditions. The resulting solution is rotational following the analyses presented by Culick for a cylindrical motor. In an extension to Culick's work, Clayton has recently managed to incorporate the effect of tapered walls. Here, an approach similar to that of Clayton is applied to a slab motor in which the chamber is modeled as a rectangular channel with tapered sidewalls. The solutions are shown to be reducible, at leading order, to Taylor's inviscid profile in a porous channel. The analysis also captures the generation of vorticity at the surface of the propellant and its transport along the streamlines. It is from the axial pressure gradient that the proper form of the vorticity is ascertained. Regular perturbations are then used to solve the vorticity equation that prescribes the mean flow motion. Subsequently, numerical simulations via a finite volume solver are carried out to gain further confidence in the analytical approximations. In illustrating the effects of the taper on flow conditions, comparisons of total pressure and velocity profiles in tapered and nontapered chambers are entertained. Finally, a comparison with the axisymmetric flow analog is presented.

  19. Turbine airfoil fabricated from tapered extrusions

    Science.gov (United States)

    Marra, John J

    2013-07-16

    An airfoil (30) and fabrication process for turbine blades with cooling channels (26). Tapered tubes (32A-32D) are bonded together in a parallel sequence, forming a leading edge (21), a trailing edge (22), and pressure and suction side walls (23, 24) connected by internal ribs (25). The tapered tubes may be extruded without camber to simplify the extrusion process, then bonded along matching surfaces (34), forming a non-cambered airfoil (28), which may be cambered in a hot forming process and cut (48) to length. The tubes may have tapered walls that are thinner at the blade tip (T1) than at the base (T2), reducing mass. A cap (50) may be attached to the blade tip. A mounting lug (58) may be forged (60) on the airfoil base and then machined, completing the blade for mounting in a turbine rotor disk.

  20. Tapered photonic crystal fibers for blue-enhanced supercontinuum generation

    DEFF Research Database (Denmark)

    Møller, Uffe; Sørensen, Simon Toft; Larsen, Casper

    2012-01-01

    Tapering of photonic crystal fibers is an effective way of shifting the blue edge of a supercontinuum spectrum down in the deep-blue. We discuss the optimum taper profile for enhancing the power in the blue edge....

  1. High efficiency and high-energy intra-cavity beam shaping laser

    International Nuclear Information System (INIS)

    Yang, Hailong; Meng, Junqing; Chen, Weibiao

    2015-01-01

    We present a technology of intra-cavity laser beam shaping with theory and experiment to obtain a flat-top-like beam with high-pulse energy. A radial birefringent element (RBE) was used in a crossed Porro prism polarization output coupling resonator to modulate the phase delay radially. The reflectively of a polarizer used as an output mirror was variable radially. A flat-top-like beam with 72.5 mJ, 11 ns at 20 Hz was achieved by a side-pumped Nd:YAG zigzag slab laser, and the optical-to-optical conversion efficiency was 17.3%. (paper)

  2. High efficiency and high-energy intra-cavity beam shaping laser

    Science.gov (United States)

    Yang, Hailong; Meng, Junqing; Chen, Weibiao

    2015-09-01

    We present a technology of intra-cavity laser beam shaping with theory and experiment to obtain a flat-top-like beam with high-pulse energy. A radial birefringent element (RBE) was used in a crossed Porro prism polarization output coupling resonator to modulate the phase delay radially. The reflectively of a polarizer used as an output mirror was variable radially. A flat-top-like beam with 72.5 mJ, 11 ns at 20 Hz was achieved by a side-pumped Nd:YAG zigzag slab laser, and the optical-to-optical conversion efficiency was 17.3%.

  3. All-solid-state continuous-wave doubly resonant all-intracavity sum-frequency mixer.

    Science.gov (United States)

    Kretschmann, H M; Heine, F; Huber, G; Halldórsson, T

    1997-10-01

    A new resonator design for doubly resonant continuous-wave intracavity sum-frequency mixing is presented. We generated 212 mW of coherent radiation at 618 nm by mixing the radiation of a 1080-nm Nd(3+):YAlO(3) laser and a 1444-nm Nd(3+):YAG laser. Two different mixing resonator setups and several nonlinear-optical crystals were investigated. So far output is limited by unequal performance of the two fundamental lasers and coating problems of the nonlinear crystals.

  4. Energy Efficiency of an Intracavity Coupled, Laser-Driven Linear Accelerator Pumped by an External Laser

    International Nuclear Information System (INIS)

    Neil Na, Y.C.; Siemann, R.H.; SLAC; Byer, R.L.; Stanford U., Phys. Dept.

    2005-01-01

    We calculate the optimum energy efficiency of a laser-driven linear accelerator by adopting a simple linear model. In the case of single bunch operation, the energy efficiency can be enhanced by incorporating the accelerator into a cavity that is pumped by an external laser. In the case of multiple bunch operation, the intracavity configuration is less advantageous because the strong wakefield generated by the electron beam is also recycled. Finally, the calculation indicates that the luminosity of a linear collider based on such a structure is comparably small if high efficiency is desired

  5. Widely tunable terahertz source based on intra-cavity frequency mixing in quantum cascade laser arrays

    International Nuclear Information System (INIS)

    Jiang, Aiting; Jung, Seungyong; Jiang, Yifan; Kim, Jae Hyun; Belkin, Mikhail A.; Vijayraghavan, Karun

    2015-01-01

    We demonstrate a compact monolithic terahertz source continuously tunable from 1.9 THz to 3.9 THz with the maximum peak power output of 106 μW at 3.46 THz at room temperature. The source consists of an array of 10 electrically tunable quantum cascade lasers with intra-cavity terahertz difference-frequency generation. To increase fabrication yield and achieve high THz peak power output in our devices, a dual-section current pumping scheme is implemented using two electrically isolated grating sections to independently control gain for the two mid-IR pumps

  6. Time-Gating Processes in Intra-Cavity Mode-Locking Devices Like Saturable Absorbers and Kerr Cells

    Science.gov (United States)

    Prasad, Narasimha; Roychoudhuri, Chandrasekhar

    2010-01-01

    Photons are non-interacting entities. Light beams do not interfere by themselves. Light beams constituting different laser modes (frequencies) are not capable of re-arranging their energies from extended time-domain to ultra-short time-domain by themselves without the aid of light-matter interactions with suitable intra-cavity devices. In this paper we will discuss the time-gating properties of intra-cavity "mode-locking" devices that actually help generate a regular train of high energy wave packets.

  7. Performance of an elliptically tapered neutron guide

    International Nuclear Information System (INIS)

    Muehlbauer, Sebastian; Stadlbauer, Martin; Boeni, Peter; Schanzer, Christan; Stahn, Jochen; Filges, Uwe

    2006-01-01

    Supermirror coated neutron guides are used at all modern neutron sources for transporting neutrons over large distances. In order to reduce the transmission losses due to multiple internal reflection of neutrons, ballistic neutron guides with linear tapering have been proposed and realized. However, these systems suffer from an inhomogeneous illumination of the sample. Moreover, the flux decreases significantly with increasing distance from the exit of the neutron guide. We propose using elliptically tapered guides that provide a more homogeneous phase space at the sample position as well as a focusing at the sample. Moreover, the design of the guide system is simplified because ellipses are simply defined by their long and short axes. In order to prove the concept we have manufactured a doubly focusing guide and investigated its properties with neutrons. The experiments show that the predicted gains using the program package McStas are realized. We discuss several applications of elliptic guides in various fields of neutron physics

  8. Performance of a tapered pulse tube

    International Nuclear Information System (INIS)

    Swift, G.; Allen, M.; Woolan, J.J.

    1998-02-01

    In a well instrumented pulse tube refrigerator having 1,500 W of cooling power at 125 K, the authors have measured the figure of merit of a tapered pulse tube at several operating points. At operating points near the operating point for which the taper was designed, the figure of merit is 0.96. This is close to the theoretical optimum figure of merit 0.97 calculated for this pulse tube considering only two loss mechanisms: heat conduction in the metal pulse tube wall and ordinary thermoacoustic heat transport in the gas within a few thermal penetration depths of the wall. At operating points farther from the design operating point, the measured figure of merit is much lower, as streaming driven convection adds a third loss mechanism

  9. Tapering Practices of Croatian Open-Class Powerlifting Champions.

    Science.gov (United States)

    Grgic, Jozo; Mikulic, Pavle

    2017-09-01

    Grgic, J and Mikulic, P. Tapering practices of Croatian open-class powerlifting champions. J Strength Cond Res 31(9): 2371-2378, 2017-The aim of this study was to explore tapering practices among 10 Croatian open-class powerlifting champions (mean ± SD: age 29.2 ± 3.2 years; Wilks coefficient 355.1 ± 54.8). The athletes were interviewed about their tapering practices using a semi-structured interview after which the audio content was transcribed. The athletes reported decreasing training volume during the taper by 50.5 ± 11.7% using a step type or an exponential type of taper with a fast decay. Training intensity was maintained or increased during the taper, and it reached its highest values 8 ± 3 days before the competition. Training frequency was reduced or maintained during the taper. The final week included a reduction in training frequency by 47.9 ± 17.5% with the last training session performed 3 ± 1 days before the competition. The participants typically stated that the main reasons for conducting the taper were maintaining strength and reducing the amount of fatigue. They also stated that (a) the taper was structured identically for the squat, bench press, and the deadlift; (b) the training during the taper was highly specific, the assistance exercises were removed, and the same equipment was used as during competition; (c) the source of information for tapering was their coach, and training fluctuated based on the coach's feedback; and (d) nutrition, foam rolling, static stretching, and massage were all given extra attention during the taper. These results may aid athletes and coaches in strength sports in terms of the optimization of tapering variables.

  10. Anisotropic optical feedback of single frequency intra-cavity He–Ne laser

    International Nuclear Information System (INIS)

    Lu-Fei, Zhou; Shu-Lian, Zhang; Yi-Dong, Tan; Wei-Xin, Liu; Bin, Zhang

    2009-01-01

    This paper presents the anisotropic optical feedback of a single frequency intra-cavity He–Ne laser. A novel phenomenon was discovered that the laser output an elliptical polarized frequency instead of the initial linear polarized one. Two intensities with a phase difference were detected, both of which were modulated in the form of cosine wave and a fringe shift corresponds to a λ/2 movement of the feedback mirror. The phase difference can be continuously modulated by the wave plate in the external cavity. Frequency stabilization was used to stabilize the laser frequency so as to enlarge the measuring range and improve the measurement precision. This anisotropic optical feedback system offers a potential displacement measurement technology with the function of subdivision of λ/2 and in-time direction judgment. The three-mirror Fabry–Perot cavity model is used to present the experimental results. Given the lack of need of lasing adjustment, this full intra-cavity laser can significantly improve the simplicity and stability of the optical feedback system. (fluids, plasmas and electric discharges)

  11. Misalignment sensitivity in an intra-cavity coherently combined crossed-Porro resonator configuration

    Science.gov (United States)

    Alperovich, Z.; Buchinsky, O.; Greenstein, S.; Ishaaya, A. A.

    2017-08-01

    We investigate the misalignment sensitivity in a crossed-Porro resonator configuration when coherently combining two pulsed multimode Nd:YAG laser channels. To the best of our knowledge, this is the first reported study of this configuration. The configuration is based on a passive intra-cavity interferometric combiner that promotes self-phase locking and coherent combining. Detailed misalignment sensitivity measurements are presented, examining both translation and angular deviations of the end prisms and combiner, and are compared to the results for standard flat end-mirror configurations. The results show that the most sensitive parameter in the crossed-Porro resonator configuration is the angular tuning of the intra-cavity interferometric combiner, which is ~±54 µrad. In comparison, with the flat end mirror configuration, the most sensitive parameter in the resonator is the angular tuning of the output coupler, which is ~±11 µrad. Thus, with the crossed-Porro configuration, we obtain significantly reduced sensitivity. This ability to reduce the misalignment sensitivity in coherently combined solid-state configurations may be beneficial in paving their way into practical use in a variety of demanding applications.

  12. Fiber-ring laser-based intracavity photoacoustic spectroscopy for trace gas sensing.

    Science.gov (United States)

    Wang, Qiang; Wang, Zhen; Chang, Jun; Ren, Wei

    2017-06-01

    We demonstrated a novel trace gas sensing method based on fiber-ring laser intracavity photoacoustic spectroscopy. This spectroscopic technique is a merging of photoacoustic spectroscopy (PAS) with a fiber-ring cavity for sensitive and all-fiber gas detection. A transmission-type PAS gas cell (resonant frequency f0=2.68  kHz) was placed inside the fiber-ring laser to fully utilize the intracavity laser power. The PAS signal was excited by modulating the laser wavelength at f0/2 using a custom-made fiber Bragg grating-based modulator. We used this spectroscopic technique to detect acetylene (C2H2) at 1531.6 nm as a proof of principle. With a low Q-factor (4.9) of the PAS cell, our sensor achieved a good linear response (R2=0.996) to C2H2 concentration and a minimum detection limit of 390 ppbv at 2-s response time.

  13. Production of High Intracavity UV Power From a CW Laser Source

    Science.gov (United States)

    David, R. T.; Chyba, T. H.; Keppel, C. E.; Gaskell, D.; Ent, R.

    1998-01-01

    The goal of this research project is to create a prototype high power CW source of ultraviolet (UV) photons for photon-electron scattering at the Thomas Jefferson National Accelerator Facility (TJNAF), Hall B. The facility will use optical resonant cavities to produce a high photon flux. The technical approach will be to frequency-double the 514.5 mn light from an Argon-Ion Laser to create 0.1 to 1.0 watt in the UV. The produced UV power will be stored in a resonant cavity to generate an high intracavity UV power of 102 to 103 watts. The specific aim of this project is to first design and construct the low-Q doubling cavity and lock it to the Argon-Ion wavelength. Secondly, the existing 514.5 nm high-Q build-up cavity and its locking electronics will be modified to create high intracavity UV power. The entire system will then be characterized and evaluated for possible beam line use.

  14. Bragg-Scattering Four-Wave Mixing in Nonlinear Fibers with Intracavity Frequency-Shifted Laser Pumps

    Directory of Open Access Journals (Sweden)

    Katarzyna Krupa

    2012-01-01

    Full Text Available We experimentally study four-wave mixing in highly nonlinear fibers using two independent and partially coherent laser pumps and a third coherent signal. We focus our attention on the Bragg-scattering frequency conversion. The two pumps were obtained by amplifying two Intracavity frequency-shifted feedback lasers working in a continuous wave regime.

  15. Manipulating the wavelength-drift of a Tm laser for resonance enhancement in an intra-cavity pumped Ho laser.

    Science.gov (United States)

    Huang, Haizhou; Huang, Jianhong; Liu, Huagang; Li, Jinhui; Lin, Zixiong; Ge, Yan; Dai, Shutao; Deng, Jing; Lin, Wenxiong

    2018-03-05

    We demonstrate an enhancement mechanism and thermal model for intra-cavity pumped lasers, where resonance enhancement in intra-cavity pumped Ho laser was achieved by manipulating the wavelength-drift nature of the Tm laser for the first time. Optical conversion efficiency of 37.5% from an absorbed 785 nm diode laser to a Ho laser was obtained with a maximum output power of 7.51 W at 2122 nm, which is comparable to the conversion efficiency in 1.9 μm LD pumped Ho lasers. Meanwhile, more severe thermal effects in the Ho-doped gain medium than the Tm-doped one at high power operation were verified based on the built thermal model. This work benefits the design or evaluation of intra-cavity pumped lasers, and the resonance enhancement originated from the difference in reabsorption loss between stark levels at the lasing manifolds of quasi-three-level rare-earth ions has great interest to improve the existing intra-cavity pumped lasers or explore novel lasers.

  16. Phase Centers of Subapertures in a Tapered Aperture Array.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Bickel, Douglas L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-11-01

    Antenna apertures that are tapered for sidelobe control can also be parsed into subapertures for Direction of Arrival (DOA) measurements. However, the aperture tapering complicates phase center location for the subapertures, knowledge of which is critical for proper DOA calculation. In addition, tapering affects subaperture gains, making gain dependent on subaperture position. Techniques are presented to calculate subaperture phase center locations, and algorithms are given for equalizing subapertures’ gains. Sidelobe characteristics and mitigation are also discussed.

  17. Optimum PCF tapers for blue-enhanced supercontinuum sources

    DEFF Research Database (Denmark)

    Møller, Uffe Visbech; Sørensen, Simon Toft; Larsen, Casper

    2012-01-01

    Tapering of photonic crystal fibers has proven to be an effective way of blueshifting the dispersive wavelength edge of a supercontinuum spectrum down in the deep-blue. In this article we will review the state-of-the-art in fiber tapers, and discuss the underlying mechanisms of supercontinuum gen...... and tapered fibers, and we demonstrate that the intensity noise at the spectral edges of the generated supercontinuum is at a constant level independent on the pump power in both tapered and uniform fibers....

  18. Monitoring techniques for the manufacture of tapered optical fibers.

    Science.gov (United States)

    Mullaney, Kevin; Correia, Ricardo; Staines, Stephen E; James, Stephen W; Tatam, Ralph P

    2015-10-01

    The use of a range of optical techniques to monitor the process of fabricating optical fiber tapers is investigated. Thermal imaging was used to optimize the alignment of the optical system; the transmission spectrum of the fiber was monitored to confirm that the tapers had the required optical properties and the strain induced in the fiber during tapering was monitored using in-line optical fiber Bragg gratings. Tapers were fabricated with diameters down to 5 μm and with waist lengths of 20 mm using single-mode SMF-28 fiber.

  19. Laminar phase flow for an exponentially tapered Josephson oscillator

    DEFF Research Database (Denmark)

    Benabdallah, A.; Caputo, J. G.; Scott, Alwyn C.

    2000-01-01

    Exponential tapering and inhomogeneous current feed were recently proposed as means to improve the performance of a Josephson flux flow oscillator. Extensive numerical results backed up by analysis are presented here that support this claim and demonstrate that exponential tapering reduces...... the small current instability region and leads to a laminar flow regime where the voltage wave form is periodic giving the oscillator minimal spectral width. Tapering also leads to an increased output power. Since exponential tapering is not expected to increase the difficulty of fabricating a flux flow...

  20. Development of novel tapered-monocapillary optics

    International Nuclear Information System (INIS)

    Hirsch, Gregory

    2000-01-01

    A new approach for producing tapered-moncapillary optics has been demonstrated. The fabrication process permits the production of metal optics which are accurately shaped, extremely straight, and have very low surface-roughness. Wide latitude in the selection of materials comprising the optics is possible. Preliminary experiments using gold paraboloidal-capillaries have demonstrated flux-density gains approaching 100 in 10-micron focused beams. The fabrication process, testing procedures, and experimental results are described. Potential improvements to the optics for achieving higher gains and smaller spot-sizes are discussed

  1. Exponentially tapered Josephson flux-flow oscillator

    DEFF Research Database (Denmark)

    Benabdallah, A.; Caputo, J. G.; Scott, Alwyn C.

    1996-01-01

    We introduce an exponentially tapered Josephson flux-flow oscillator that is tuned by applying a bias current to the larger end of the junction. Numerical and analytical studies show that above a threshold level of bias current the static solution becomes unstable and gives rise to a train...... of fluxons moving toward the unbiased smaller end, as in the standard flux-flow oscillator. An exponentially shaped junction provides several advantages over a rectangular junction including: (i) smaller linewidth, (ii) increased output power, (iii) no trapped flux because of the type of current injection...

  2. Intracavity Laser Refractometry In Reflection: Development And Implementation In Biomedical Investigations

    International Nuclear Information System (INIS)

    Gonchukov, S. A.

    2010-01-01

    The Intracavity Laser Refractometry in Reflection (ILRR) method is developed for precise investigation of the processes on an interface of different media in real time. This method is very attractive for the study of biological liquids. It is based on the control of two-mode phase-anisotropic laser spectrum. In the aggregate the values of the sensitivity, time of measuring, potential parameters of investigated media of ILRR method correspond to the best results in optical refractometry. The absolute value of refractive index correlates with the course of different diseases. It can serve the objective parameter for an estimation of a level of illness processes in organism and drug efficiency. In result of the investigation of the photoresponse of the blood to low-level laser irradiation both the slow thermal effect and fast biophysical effect were discovered. The refractive index behaviour in real time allows the photoacceptors and maximum therapeutic doses on organism, cellular, and molecular levels to be determined.

  3. Dynamics of injection locking in a solid-state laser with intracavity second-harmonic generation

    International Nuclear Information System (INIS)

    Zolotoverkh, I I; Lariontsev, E G

    2000-01-01

    The dynamics of oscillation in a solid-state laser with intracavity second-harmonic generation under the influence of an external signal at the second-harmonic frequency injected into its cavity in the presence of feedback at the double frequency is theoretically studied. Boundaries of the regions of injection locking for three stationary laser states differing in the nonlinear phase incursion caused by radiation conversion into the second harmonic are found. Relaxation oscillations in the stationary state of injection locking are studied. It is shown that the second relaxation frequency, which is related to phase perturbations of the second harmonic and perturbations of the phase difference of waves in a nonlinear crystal, is excited in a single-mode solid-state laser in addition to the fundamental frequency of relaxation oscillations. Conditions are found under which relaxation oscillations at the second relaxation frequency are excited. (lasers)

  4. Tunable femtosecond laser in the visible range with an intracavity frequency-doubled optical parametric oscillator

    International Nuclear Information System (INIS)

    Zhu Jiang-Feng; Xu Liang; Lin Qing-Feng; Zhong Xin; Han Hai-Nian; Wei Zhi-Yi

    2013-01-01

    We demonstrated experimentally a synchronously pumped intracavity frequency-doubled femtosecond optical parametric oscillator (OPO) using a periodically-poled lithium niobate (PPLN) as the nonlinear material in combination with a lithium triborate (LBO) as the doubling crystal. A Kerr-lens-mode-locked (KLM) Ti:sapphire oscillator at the wavelength of 790 nm was used as the pump source, which was capable of generating pulses with a duration as short as 117 fs. A tunable femtosecond laser covering the 624–672 nm range was realized by conveniently adjusting the OPO cavity length. A maximum average output power of 260 mW in the visible range was obtained at the pump power of 2.2 W, with a typical pulse duration of 205 fs assuming a sech 2 pulse profile. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  5. Intracavity optogalvanic spectroscopy. An analytical technique for 14C analysis with subattomole sensitivity.

    Science.gov (United States)

    Murnick, Daniel E; Dogru, Ozgur; Ilkmen, Erhan

    2008-07-01

    We show a new ultrasensitive laser-based analytical technique, intracavity optogalvanic spectroscopy, allowing extremely high sensitivity for detection of (14)C-labeled carbon dioxide. Capable of replacing large accelerator mass spectrometers, the technique quantifies attomoles of (14)C in submicrogram samples. Based on the specificity of narrow laser resonances coupled with the sensitivity provided by standing waves in an optical cavity and detection via impedance variations, limits of detection near 10(-15) (14)C/(12)C ratios are obtained. Using a 15-W (14)CO2 laser, a linear calibration with samples from 10(-15) to >1.5 x 10(-12) in (14)C/(12)C ratios, as determined by accelerator mass spectrometry, is demonstrated. Possible applications include microdosing studies in drug development, individualized subtherapeutic tests of drug metabolism, carbon dating and real time monitoring of atmospheric radiocarbon. The method can also be applied to detection of other trace entities.

  6. Intra-Cavity Total Reflection For High Sensitivity Measurement Of Optical Properties

    Science.gov (United States)

    Pipino, Andrew Charles Rule

    1999-11-16

    An optical cavity resonator device is provided for conducting sensitive murement of optical absorption by matter in any state with diffraction-limited spatial resolution through utilization of total internal reflection within a high-Q (high quality, low loss) optical cavity. Intracavity total reflection generates an evanescent wave that decays exponentially in space at a point external to the cavity, thereby providing a localized region where absorbing materials can be sensitively probed through alteration of the Q-factor of the otherwise isolated cavity. When a laser pulse is injected into the cavity and passes through the evanescent state, an amplitude loss resulting from absorption is incurred that reduces the lifetime of the pulse in the cavity. By monitoring the decay of the injected pulse, the absorption coefficient of manner within the evanescent wave region is accurately obtained from the decay time measurement.

  7. Photon statistics of a single-atom intracavity system involving electromagnetically induced transparency

    International Nuclear Information System (INIS)

    Rebic, S.; Parkins, A.S.; Tan, S.M.

    2002-01-01

    We explore the photon statistics of light emitted from a system comprising a single four-level atom strongly coupled to a high-finesse optical cavity mode that is driven by a coherent laser field. In the weak driving regime this system is found to exhibit a photon blockade effect. For intermediate driving strengths we find a sudden change in the photon statistics of the light emitted from the cavity. Photon antibunching switches to photon bunching over a very narrow range of intracavity photon number. It is proven that this sudden change in photon statistics occurs due to the existence of robust quantum interference of transitions between the dressed states of the atom-cavity system. Furthermore, it is shown that the strong photon bunching is a nonclassical effect for certain values of driving field strength, violating classical inequalities for field correlations

  8. High-efficiency intracavity second-harmonic enhancement for a few-cycle laser pulse train

    International Nuclear Information System (INIS)

    Cai, Yi; Xu, Shixiang; Zeng, Xuanke; Zou, Da; Li, Jingzhen

    2012-01-01

    This paper presents an intracavity second-harmonic (SH) enhancement technology without the need of input impedance-matching for optimal coupling between the cavity and its input frequency comb. More than 10% SH energy conversion efficiency is available, thus the power of the SH frequency comb can be enhanced beyond 100 relative to single-pass SH generation. Compared with a conventional passive enhancing cavity, for the purpose of high power enhancement, our scheme can operate at much lower finesse and thus broader bandwidth so that it can support several-optical-cycle pulses more easily. If they have the same finesse, both methods perform with similar operating stability. The results show that our novel design is suitable for some applications which need a short wavelength, high intensity, and ultra-broad bandwidth pulse train. (paper)

  9. Plasma magnetic field measurement by intracavity absorption. Progress report, June 1, 1983-May 31, 1984

    International Nuclear Information System (INIS)

    Brink, G.O.

    1984-01-01

    Dye laser intracavity absorption (ICA) is being studied as a potential diagnostic for plasma or neutral beam systems. For magnetic field measurements it is necessary to make Zeeman effect measurements on the resonance transition of atomic lithium on a millisecond time scale. To do this it is necessary to sweep the dye laser in wavelength at a rapid rate so that the absorber can be sampled many times during the measurement. Our results indicate that the ICA signal becomes small at high sweep rates limiting the rate at which such sweeping may be carried out. It may be possible to avoid this limitation by chopping the pump laser. The studies of coupled cavity ICA are continuing, and are discussed in detail in an appendix. An ICA system using a dye cell has been designed, and supplementary experiments involving the observation of ICA in a ring dye laser are discussed

  10. Intracavity optogalvanic spectroscopy: Is there any evidence of a radiocarbon signal?

    International Nuclear Information System (INIS)

    Persson, Anders; Salehpour, Mehran

    2015-01-01

    In 2008, the first report of an ultrasensitive method for ro-vibrational spectrometry of radiocarbon dioxide was published. The method, called intracavity optogalvanic spectroscopy (ICOGS), claimed a sensitivity and limit-of-detection comparable to accelerator mass spectroscopy. ICOGS was claimed to utilize the isotope-dependent ro-vibrational absorption lines of carbon dioxide in the infrared spectrum. In order to facilitate unambiguous detection of radiocarbon, the sample was placed inside the cavity of a radiocarbon dioxide laser. This intracavity approach was claimed to increase the sensitivity by seven orders of magnitude compared with traditional optogalvanic methods. However, despite the methodical and thorough efforts of several research groups worldwide, these claims have not been possible to reproduce. Instead, we have previously reported serious deviations from the original results, where we found that ICOGS suffers from considerable problems with the stability and reproducibility of the optogalvanic signal, and that misinterpretations of these uncertainties likely are the explanation for the claimed sensitivity in the first reports. Having identified the stability and reproducibility of the detection as major concerns, we decided to improve the setup by with state-of-the-art plasma source technology. Deploying a custom-made stripline split-ring resonator optogalvanic detector, we have now investigated the applicability of ICOGS to radiocarbon detection even further. Measurements have been made with a wide range of parameters including different gas mixtures at various pressures and wavelengths. We have also conducted measurements with gas flowing through the sample cell to investigate the effect of plasma induced decomposition of the sample. Still, we have seen no indications of a significant radiocarbon signal in a concentration range between 0.29 Modern and 9.7 Modern, i.e., the range of interest to the radiocarbon community. Hence, our conclusions

  11. Quantum variational measurement and the optical lever intracavity topology of gravitational-wave detectors

    International Nuclear Information System (INIS)

    Khalili, F. Ya.

    2007-01-01

    The intracavity topologies of laser gravitational-wave detectors proposed several years ago are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). In essence, the intracavity detector is a two-stage device where the end mirrors displacement created by the gravitational wave is transferred to the displacement of an additional local mirror by means of the optical rigidity. The local mirror positions have to be monitored by an additional local meter. It is evident that the local meter precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter backaction noise and measurement noise is introduced, which allows us to eliminate the backaction noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment, an approximate 10 m long filter cavity can be used to obtain sensitivity approximately 2-3 times better than the SQL. For future Quantum Non-Demolition (QND) gravitational-wave detectors with sensitivity about 10 times better than the SQL, the filter cavity length should be within kilometer range

  12. Chemical tapering of polymer optical fiber

    Science.gov (United States)

    Rashid, Affa Rozana Abdul; Afiqah Nasution, Amna; Hanim Suranin, Aisyah; Athirah Taib, Nur; Maisarah Mukhtar, Wan; Dasuki, Karsono Ahmad; Annuar Ehsan, Abang

    2017-11-01

    Polymer optical fibers (POFs) have significant advantages over numerous sensing applications. The key element in developing sensor is by removing the cladding of the fiber. The use of organic solvent is one of the methods to create tapered POF in order to expose the core region. In this study, the etching chemicals involved is acetone, methyl isobutyl ketone (MIBK), and acetone-methanol mixture. The POF is immersed in 100%, 80%, and 50% of acetone and MIBK dilution. In addition, the mixture of acetone and methanol is also used for POF etching by the ratio 2:1 of the volume. Acetone has shown to be the most reactive solvent towards POF due to its fastest etching rate compared to MIBK and acetone-methanol mixture. The POF is immersed and lifted from the solution for a specific time, depending on the power loss properties for the purpose of producing unclad POF. In comparison to silica fiber optic, the advantages of POF in terms of its simple technique and easy handling enable it to produce unclad POF without damaging the core region. The surface roughness of the POF is investigated under the microscope after being immersed into different solvent. This method of chemical tapering of POF can be used as the fundamental technique for sensor development. Next, the unclad fiber is immersed into ethanol solutions in order to determine the reaction of unclad POF towards its surrounding. The findings show that this particular sensor is sensitive towards concentration changes ranging between 10 wt% to 50 wt%.

  13. Wavelength stabilisation during current pulsing of tapered laser

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin

    2009-01-01

    The use of external feedback to stabilise the frequency of a tapered laser during current pulsing is reported. Using this technique more than 20 W of peak power in 60 ns pulses from the tapered laser is obtained and owing to the external feedback, the laser is tunable in the 778-808 nm range...

  14. Catalog of Window Taper Functions for Sidelobe Control

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W.

    2017-04-01

    Window taper functions of finite apertures are well-known to control undesirable sidelobes, albeit with performance trades. A plethora of various taper functions have been developed over the years to achieve various optimizations. We herein catalog a number of window functions, and com pare principal characteristics.

  15. High power supercontinuum generation in tapered photonic crystal fibers

    DEFF Research Database (Denmark)

    Møller, Uffe; Sørensen, Simon Toft; Larsen, Casper

    2012-01-01

    the concept of a group-acceleration mismatch, that for a given taper length, the downtapering section should be as long as possible to enhance the amount of blueshifted light. We also discuss the noise properties of supercontinuum in uniform and tapered fibers and we demonstrate that the amplitude noise...

  16. The effect of tapering on a magnetocaloric regenerator bed

    DEFF Research Database (Denmark)

    Dallolio, Stefano; Lei, Tian; Engelbrecht, Kurt

    2017-01-01

    . Therefore, this paper investigates the effect of the tapering of the regenerators, which exhibit better air-gap utilization. Several simulations using a 1D AMR model were run to study the performance of the tapered regenerator, and the results were compared to the case of the straight regenerator bed...

  17. An Exact Analytical Solution to Exponentially Tapered Piezoelectric Energy Harvester

    Directory of Open Access Journals (Sweden)

    H. Salmani

    2015-01-01

    Full Text Available It has been proven that tapering the piezoelectric beam through its length optimizes the power extracted from vibration based energy harvesting. This phenomenon has been investigated by some researchers using semianalytical, finite element and experimental methods. In this paper, an exact analytical solution is presented to calculate the power generated from vibration of exponentially tapered unimorph and bimorph with series and parallel connections. The mass normalized mode shapes of the exponentially tapered piezoelectric beam with tip mass are implemented to transfer the proposed electromechanical coupled equations into modal coordinates. The steady states harmonic solution results are verified both numerically and experimentally. Results show that there exist values for tapering parameter and electric resistance in a way that the output power per mass of the energy harvester will be maximized. Moreover it is concluded that the electric resistance must be higher than a specified value for gaining more power by tapering the beam.

  18. A high-energy, low-threshold tunable intracavity terahertz-wave parametric oscillator with surface-emitted configuration

    International Nuclear Information System (INIS)

    Wang, Y Y; Xu, D G; Jiang, H; Zhong, K; Yao, J Q

    2013-01-01

    A high-energy, low-threshold THz-wave output has been experimentally demonstrated with an intracavity terahertz-wave parametric oscillator based on a surface-emitted configuration, which was pumped by a diode-side-pumped Q-switched Nd:YAG laser. Different beam sizes and repetition rates of the pump light have been investigated for high-energy and high-efficiency THz-wave generation. The maximum THz-wave output energy of 283 nJ/pulse was obtained at 1.54 THz under an intracavity 1064 nm pump energy of 59 mJ. The conversion efficiency was 4.8 × 10 −6 , corresponding to a photon conversion efficiency of 0.088%. The pump threshold was 12.9 mJ/pulse. A continuously tunable range from 0.75 to 2.75 THz was realized. (paper)

  19. Passive mode locking at harmonics of the free spectral range of the intracavity filter in a fiber ring laser.

    Science.gov (United States)

    Zhang, Shumin; Lu, Fuyun; Dong, Xinyong; Shum, Ping; Yang, Xiufeng; Zhou, Xiaoqun; Gong, Yandong; Lu, Chao

    2005-11-01

    We report the passive mode-locking at harmonics of the free spectral range (FSR) of the intracavity multi-channel filter in a fiber ring laser. The laser uses a sampled fiber Bragg grating (SFBG) with a free spectral range (FSR) of 0.8 nm, or 99 GHz at 1555 nm, and a length of highly nonlinear photonic crystal fiber with low and flat dispersion. Stable picosecond soliton pulse trains with twofold to sevenfold enhancement in the repetition rate, relative to the FSR of the SFBG, have been achieved. The passive mode-locking mechanism that is at play in this laser relies on a dissipative four-wave mixing process and switching of repetition rate is realized simply by adjustment of the intracavity polarization controllers.

  20. End-pumped continuous-wave intracavity yellow Raman laser at 590 nm with SrWO4 Raman crystal

    Science.gov (United States)

    Yang, F. G.; You, Z. Y.; Zhu, Z. J.; Wang, Y.; Li, J. F.; Tu, C. Y.

    2010-01-01

    We present an end-pumped continuous-wave intra-cavity yellow Raman laser at 590 nm with a 60 mm long pure crystal SrWO4 and an intra-cavity LiB3O5 frequency doubling crystal. The highest output power of yellow laser at 590 nm was 230 mW and the output power and threshold were found to be correlative with the polarized directions of pure single crystal SrWO4 deeply. Along different directions, the minimum and maximum thresholds of yellow Raman laser at 590 nm were measured to be 2.8 W and 14.3 W with respect to 808 nm LD pump power, respectively.

  1. End-pumped continuous-wave intracavity yellow Raman laser at 590 nm with SrWO4 Raman crystal

    International Nuclear Information System (INIS)

    Yang, F G; You, Z Y; Zhu, Z J; Wang, Y; Li, J F; Tu, C Y

    2010-01-01

    We present an end-pumped continuous-wave intra-cavity yellow Raman laser at 590 nm with a 60 mm long pure crystal SrWO 4 and an intra-cavity LiB 3 O 5 frequency doubling crystal. The highest output power of yellow laser at 590 nm was 230 mW and the output power and threshold were found to be correlative with the polarized directions of pure single crystal SrWO 4 deeply. Along different directions, the minimum and maximum thresholds of yellow Raman laser at 590 nm were measured to be 2.8 W and 14.3 W with respect to 808 nm LD pump power, respectively

  2. Comparison of nonpolar III-nitride vertical-cavity surface-emitting lasers with tunnel junction and ITO intracavity contacts

    KAUST Repository

    Leonard, J. T.

    2016-03-01

    We report on the lasing of III-nitride nonpolar, violet, vertical-cavity surface-emitting lasers (VCSELs) with III-nitride tunnel-junction (TJ) intracavity contacts and ion implanted apertures (IIAs). The TJ VCSELs are compared to similar VCSELs with tin-doped indium oxide (ITO) intracavity contacts. Prior to analyzing device results, we consider the relative advantages of III-nitride TJs for blue and green emitting VCSELs. The TJs are shown to be most advantageous for violet and UV VCSELs, operating near or above the absorption edge for ITO, as they significantly reduce the total internal loss in the cavity. However, for longer wavelength III-nitride VCSELs, TJs primarily offer the advantage of improved cavity design flexibility, allowing one to make the p-side thicker using a thick n-type III-nitride TJ intracavity contact. This offers improved lateral current spreading and lower loss, compare to using ITO and p-GaN, respectively. These aspects are particularly important for achieving high-power CW VCSELs, making TJs the ideal intracavity contact for any III-nitride VCSEL. A brief overview of III-nitride TJ growth methods is also given, highlighting the molecular-beam epitaxy (MBE) technique used here. Following this overview, we compare 12 mu m aperture diameter, violet emitting, TJ and ITO VCSEL experimental results, which demonstrate the significant improvement in differential efficiency and peak power resulting from the reduced loss in the TJ design. Specifically, the TJ VCSEL shows a peak power of similar to 550 mu W with a threshold current density of similar to 3.5 kA/cm(2), while the ITO VCSELs show peak powers of similar to 80 mu W and threshold current densities of similar to 7 kA/cm

  3. Comparison of nonpolar III-nitride vertical-cavity surface-emitting lasers with tunnel junction and ITO intracavity contacts

    KAUST Repository

    Leonard, J. T.; Young, E. C.; Yonkee, B. P.; Cohen, D. A.; Shen, Chao; Margalith, T.; Ng, Tien Khee; Denbaars, S. P.; Ooi, Boon S.; Speck, J. S.; Nakamura, S.

    2016-01-01

    We report on the lasing of III-nitride nonpolar, violet, vertical-cavity surface-emitting lasers (VCSELs) with III-nitride tunnel-junction (TJ) intracavity contacts and ion implanted apertures (IIAs). The TJ VCSELs are compared to similar VCSELs with tin-doped indium oxide (ITO) intracavity contacts. Prior to analyzing device results, we consider the relative advantages of III-nitride TJs for blue and green emitting VCSELs. The TJs are shown to be most advantageous for violet and UV VCSELs, operating near or above the absorption edge for ITO, as they significantly reduce the total internal loss in the cavity. However, for longer wavelength III-nitride VCSELs, TJs primarily offer the advantage of improved cavity design flexibility, allowing one to make the p-side thicker using a thick n-type III-nitride TJ intracavity contact. This offers improved lateral current spreading and lower loss, compare to using ITO and p-GaN, respectively. These aspects are particularly important for achieving high-power CW VCSELs, making TJs the ideal intracavity contact for any III-nitride VCSEL. A brief overview of III-nitride TJ growth methods is also given, highlighting the molecular-beam epitaxy (MBE) technique used here. Following this overview, we compare 12 mu m aperture diameter, violet emitting, TJ and ITO VCSEL experimental results, which demonstrate the significant improvement in differential efficiency and peak power resulting from the reduced loss in the TJ design. Specifically, the TJ VCSEL shows a peak power of similar to 550 mu W with a threshold current density of similar to 3.5 kA/cm(2), while the ITO VCSELs show peak powers of similar to 80 mu W and threshold current densities of similar to 7 kA/cm

  4. Prediction of fatigue damage in tapered laminates

    DEFF Research Database (Denmark)

    Raeis Hosseiny, Seyed Aydin; Jakobsen, Johnny

    2017-01-01

    Effective implementation of ply-drops configurations substantially improve the damage tolerant design of flexible and aero-elastic wind turbine blades. Terminating a number of layers for an optimized blade design creates local bending effects. Inter-laminar stress states in tapered areas give rise...... to delamination and premature structural failure. Precise calculation of the stress levels for embedded ply-drops is required to predict failure initiation within acceptable limits. Multi-axial stress states in orthotropic laminates subjected to diverse loading mechanisms nucleate microscopic cracks....... By increasing the cracks density, damage occurs when residual material properties reduce to a critical level. Residual strength and stiffness of simple laminates are assigned in a set of fatigue failure criteria to assess the remaining life of the components by increasing number of loading cycles. The mode...

  5. Chemical tapering of polymer optical fiber

    Directory of Open Access Journals (Sweden)

    Abdul Rashid Affa Rozana

    2017-01-01

    Full Text Available Polymer optical fibers (POFs have significant advantages over numerous sensing applications. The key element in developing sensor is by removing the cladding of the fiber. The use of organic solvent is one of the methods to create tapered POF in order to expose the core region. In this study, the etching chemicals involved is acetone, methyl isobutyl ketone (MIBK, and acetone-methanol mixture. The POF is immersed in 100%, 80%, and 50% of acetone and MIBK dilution. In addition, the mixture of acetone and methanol is also used for POF etching by the ratio 2:1 of the volume. Acetone has shown to be the most reactive solvent towards POF due to its fastest etching rate compared to MIBK and acetone-methanol mixture. The POF is immersed and lifted from the solution for a specific time, depending on the power loss properties for the purpose of producing unclad POF. In comparison to silica fiber optic, the advantages of POF in terms of its simple technique and easy handling enable it to produce unclad POF without damaging the core region. The surface roughness of the POF is investigated under the microscope after being immersed into different solvent. This method of chemical tapering of POF can be used as the fundamental technique for sensor development. Next, the unclad fiber is immersed into ethanol solutions in order to determine the reaction of unclad POF towards its surrounding. The findings show that this particular sensor is sensitive towards concentration changes ranging between 10 wt% to 50 wt%.

  6. Numerical study of hub taper angle on podded propeller performance

    International Nuclear Information System (INIS)

    Islam, M.F.; Veitch, B.; Bose, N.; Liu, P.

    2005-01-01

    Presently, the majority of podded propulsion systems are of the pulling type, because this type provides better hydrodynamic efficiency than the pushing type. There are several possible explanations for the better overall performance of a puller type podded propulsor. One is related to the difference in hub shape. Puller and pusher propellers have opposite hub taper angles, hence different hub and blade root shape. These differences cause changes in the flow condition and possibly influence the overall performance. The current study focuses on the variation in performance of pusher and puller propellers with the same blade sections, but different hub taper angles. A hyperboloidal low order source doublet steady/unsteady time domain panel method code was modified and used to evaluate effects of hub taper angle on the open water propulsive performance of some fixed pitch screw propellers used in podded propulsion systems. The modified code was first validated against measurements of two model propellers in terms of average propulsive performance and good agreement was found. Major findings include significant effects of hub taper angle on propulsive performance of tapered hub propellers and noticeable effects of hub taper angle on sectional pressure distributions of tapered hub propeller blades. (author)

  7. Tapered diode laser pumped 946 nm Nd:YAG laser

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Jensen, Ole Bjarlin; Petersen, Paul Michael

    2009-01-01

    We successfully implemented a 946 nm Nd:YAG laser based on a 808 nm tapered diode pump laser. The tapered diode is developed at the Ferdinand-Braun-Institute fur Hochstfrequenztechnik in Germany. Figure 2 shows the experimental setup and results of each pump source coupled into a 1.5 mm crystal...... laser, we show that tapered diode laser pumping potentially increase the power of 946 nm lasers by a factor of two and reduce the threshold by a factor of three....

  8. Micro-taper as focusing or scattering optical element

    Energy Technology Data Exchange (ETDEWEB)

    Degtyarev, S. A., E-mail: sealek@gmail.com; Ustinov, A. V., E-mail: andr@smr.ru; Khonina, S. N., E-mail: khonina@smr.ru [Samara State Aerospace University, Moskovskoye Shosse 34, Samara, Russia, 443086 (Russian Federation); Imaging Processing Systems Institute of the Russian Academy of Science, Molodogvardeyskaya street, 151, Samara, Russia, 443001 (Russian Federation)

    2016-04-13

    We consider micro-taper (narrow refractive axicon) as optical element which is focusing or scattering in dependence on axicon’s cone angle. The diffraction of laser beam by micro-taper is simulated by two methods: multiply internal ray reflections using geometrical approach and Helmholtz equation solving using finite elements method. Based on ray optics we derive analytic formulas for conical angles values which provide focusing or scattering features of micro-taper. Numerical simulation by finite elements method verifies theoretical results.

  9. The effect of refractive index changes in an intracavity absorption on the laser output power

    International Nuclear Information System (INIS)

    Al-Hawat, Sh.; Eskef, M.

    2007-10-01

    A model describing the intra-cavity absorption has been developed. The model allows for a reliable description of the attenuation of laser power as a function of the gas pressure inside the absorption cell, conducting both real and imaginary parts of the refractive index of the absorbing gas. The model relies on an adequate integration of the additional loss due to the absorption into the rate equations. After that the rate equations are solved under steady state conditions, which is quite reliable for a cw CO 2 laser. The oscillation, clearly observed in case of weak absorption, is described in the framework of an interference model considering the electric field inside the cavity as the interference result of successive phase correlated waves differing from each other in the number of passes made through the cavity. The phase shift is determined by the optical length of the cavity depending on the real part of the refractive index of the gas in the absorption cell. The model has been applied to analyze a large set of attenuation curves obtained in a previous work, in which intra-cavity absorption was measured for the three gases CFC-11, 12, 22 using a tunable cw CO 2 laser at 44 lines of the emission spectrum of the CO 2 molecule distributed on the branches P and R of the two bands at 9.6 μm and 10.6 μm. For mostly all examples, the value of the absorption cross section (imaginary part of the refractive index) has been determined by fitting the model to the experimental data. Furthermore, the value of the linear polarizability (real part of the refractive index) has been calculated from the oscillation period for all examples, in which the attenuation curve exhibits reliable oscillating behavior. The results are in fair agreement with the values of the absorption cross section published in the Hitran data base, as well as with the results obtained from independent absorption measurements performed outside the cavity (Author)

  10. Tapered fluorotellurite microstructured fibers for broadband supercontinuum generation.

    Science.gov (United States)

    Wang, Fang; Wang, Kangkang; Yao, Chuanfei; Jia, Zhixu; Wang, Shunbin; Wu, Changfeng; Qin, Guanshi; Ohishi, Yasutake; Qin, Weiping

    2016-02-01

    Fluorotellurite microstructured fibers (MFs) based on TeO2-BaF2-Y2O3 glasses are fabricated by using a rod-in-tube method. Tapered fluorotellurite MFs with varied transition region lengths are prepared by employing an elongation machine. By using a tapered fluorotellurite MF with a transition region length of ∼3.3  cm as the nonlinear medium and a 1560 nm femtosecond fiber laser as the pump source, broadband supercontinuum generation covering from 470 to 2770 nm is obtained. The effects of the transition region length of the tapered fluorotellurite MF on supercontinuum generation are also investigated. Our results show that tapered fluorotellurite MFs are promising nonlinear media for generating broadband supercontinuum light expanding from visible to mid-infrared spectral region.

  11. Laser at 532 nm by intracavity frequency-doubling in BBO

    Science.gov (United States)

    Yuan, Xiandan; Wang, Jinsong; Chen, Yongqi; Wu, Yulong; Qi, Yunfei; Sun, Meijiao; Wang, Qi

    2017-06-01

    A simple and compact linear resonator green laser at 532 nm is generated by intracavity frequency-doubling of a diode-side-pumped acousto-optically (AO) Q-switched Nd:YAG laser at 1064 nm. Two acousto-optic Q-switches were placed orthogonally with each other to improve the hold-off capacity. As high as 214 W of continuous-wave (CW) and 154 W of quasi-continuous-wave (QCW) output power at 1064 nm were obtained when the pumping power was 1598 W. The type I phase-matched BBO crystal was used as the nonlinear medium in the second harmonic generation. A green laser with an average output power of 37 W was obtained at a repetition rate of 20 kHz and a pulse width of 54 ns, which corresponds to pulse energy of 1.85 mJ per pulse and a peak power 34.26 kW, respectively. Project supported by the Beijing Engineering Technology Research Center of All-Solid-State Lasers Advanced Manufacturing, the National High Technology Research and Development Program of China (No. 2014AA032607), and the National Natural Science Foundation of China (Nos. 61404135, 61405186, 61308032, 61308033).

  12. Intracavity irradiation with deferred radioactive load technique, remote control high activity sources

    Energy Technology Data Exchange (ETDEWEB)

    Badell, M.; Lejarcegui, J.A.; Guix, B.; Rubio, A.; Pons, F.; Farrus, B.

    1988-01-01

    From December 1981 to September 1986, 149 patients were treated at the Radiotherapy Department of the Hospital Clinico y Provincial of Barcelona by means of intracavity irradiation with 137 cesium high 1 sources and 2. To 112 of the total number of patients external radiotherapy to the whole of the pelvis using photons of 6 MeV was also administered. A total of 46 (30.7%) patients presented rectal complications. The rectitis observed was mild in 16 cases (10.7%), moderate in 15(10%) and severe in 15(10%). The 15 patients with severe rectitis had to be treated by unloading colostomy. In patients with severe complications, the maximum total rectal dose administered was between 5,855 and 9,490 cGy, and the maximum rectal dose administered via curietherapy was 1,055 to 7,320 cGy. Maximum total rectal dose administration greater than 4,000 cGy and maximum rectal dose administered via curietherapy greater than 5,800 cGy were statistically significant prognostic factors (p < 0.001) of severe rectal complications.

  13. Wavelength tunable CW red laser generated based on an intracavity-SFG composite cavity

    Science.gov (United States)

    Zhang, Z. N.; Bai, Y.; Lei, G. Z.; Bai, B.; Sun, Y. X.; Hu, M. X.; Wang, C.; Bai, J. T.

    2016-12-01

    We report a wavelength-tunable watt-level continuous wave (CW) red laser that uses a composite cavity based on an intracavity sum-frequency generation (SFG). The composite cavity is composed of a LD side-pumped Nd: GdVO4 p-polarized 1062.9 nm resonant cavity and a resonant optical parametric oscillator (SRO) of s-polarized signal light using a periodically poled crystal MgO: PPLN. Based on the temperature tuning from 30 °C to 200 °C, the CW red laser beams are obtained in a tunable waveband from 634.4 nm to 649.1 nm, corresponding to a tunable output waveband from 3278.0 nm to 2940.2 nm of the mid-infrared idler lights. The maximum CW output power of the red laser at 634.4 nm and the idler light at 3278.0 nm reach 3.03 W and 4.13 W under 30 °C, respectively.

  14. Suppression of acoustic streaming in tapered pulse tubes

    International Nuclear Information System (INIS)

    Olson, J.R.; Swift, G.W.

    1998-01-01

    In a pulse tube cryocooler, the gas in the pulse tube can be thought of as an insulating piston, transmitting pressure and velocity from the cold heat exchanger to the hot end of the pulse tube. Unfortunately, convective heat transfer can carry heat from the hot end to the cold end and reduce the net cooling power. Here, the authors discuss one driver of such convection: steady acoustic streaming as generated by interactions between the boundary and the oscillating pressure, velocity, and temperature. Using a perturbation method, they have derived an analytical expression for the streaming in a tapered pulse tube with axially varying mean temperature in the acoustic boundary layer limit. The calculations showed that the streaming depends strongly on the taper angle, the ratio of velocity and pressure amplitudes, and the phase between the velocity and pressure, but it depends only weakly on the mean temperature profile and is independent of the overall oscillatory amplitude. With the appropriate tapering of the tube, streaming can be eliminated for a particular operating condition. Experimentally, the authors have demonstrated that an orifice pulse tube cryocooler with the calculated zero-streaming taper has more cooling power than one with either a cylindrical tube or a tapered pulse tube with twice the optimum taper angle

  15. Shear Adhesion of Tapered Nanopillar Arrays.

    Science.gov (United States)

    Cho, Younghyun; Minsky, Helen K; Jiang, Yijie; Yin, Kaiyang; Turner, Kevin T; Yang, Shu

    2018-04-04

    Tapered nanopillars with various cross sections, including cone-shaped, stepwise, and pencil-like structures (300 nm in diameter at the base of the pillars and 1.1 μm in height), are prepared from epoxy resin templated by nanoporous anodic aluminum oxide (AAO) membranes. The effect of pillar geometry on the shear adhesion behavior of these nanopillar arrays is investigated via sliding experiments in a nanoindentation system. In a previous study of arrays with the same geometry, it was shown that cone-shaped nanopillars exhibit the highest adhesion under normal loading while stepwise and pencil-like nanopillars exhibit lower normal adhesion strength due to significant deformation of the pillars that occurs with increasing indentation depth. Contrary to the previous studies, here, we show that pencil-like nanopillars exhibit the highest shear adhesion strength at all indentation depths among three types of nanopillar arrays and that the shear adhesion increases with greater indentation depth due to the higher bending stiffness and closer packing of the pencil-like nanopillar array. Finite element simulations are used to elucidate the deformation of the pillars during the sliding experiments and agree with the nanoindentation-based sliding measurements. The experiments and finite element simulations together demonstrate that the shape of the nanopillars plays a key role in shear adhesion and that the mechanism is quite different from that of adhesion under normal loading.

  16. [Shaping ability of multi-taper nickel-titanium files in simulated resin curved root canal].

    Science.gov (United States)

    Luo, Hong-Xia; Huang, Ding-Ming; Jia, Liu-He; Luo, Shi-Gao; Gao, Xiao-Jie; Tan, Hong; Zhou, Xue-Dong

    2006-08-01

    To compare the shaping ability of ISO standard stainless steel K files and multi-taper ProTaper nickel-titanium files in simulated resin curved root canals. METHODS Thirty simulated resin root canals were randomly divided into three groups and prepared by stainless steel K files, hand ProTaper, rotary ProTaper, respectively. The amount of material removed from inner and outer wall and canal width after canal preparation was measured, while the canal curvature before and after canal preparation and canals aberrations were recorded. The stainless steel K files removed more material than hand ProTaper and rotary ProTaper at the outer side of apex and inner side of curvature (P ProTaper group (P ProTaper had no evident aberration. The shaping ability of ProTaper is better than stainless steel K files.

  17. An Experimental Study of an FEL Oscillator with a Linear Taper

    International Nuclear Information System (INIS)

    Benson, S.; Gubeli, J.; Neil, G.R.

    2001-01-01

    Motivated by the work of Saldin, Schneidmiller and Yurkov, we have measured the detuning curve widths, spectral characteristics, efficiency, and energy spread as a function of the taper for low and high Q resonators in the IR Demo FEL at Jefferson Lab. Both positive and negative tapers were used. Gain and frequency agreed reasonably well with the predictions of a single mode theory. The efficiency agreed reasonably well for a negative taper with a high Q resonator but disagreed for lower Q values due to the large slippage parameter and the non-ideal resonator Q. We saw better efficiency for a negative taper than for the same positive taper. The energy spread induced in the beam, normalized to the efficiency is larger for the positive taper than for the corresponding negative taper. This indicates that a negative taper is preferred over a positive taper in an energy recovery FEL

  18. The effects of tapering on strength performance in trained athletes.

    Science.gov (United States)

    Gibala, M J; MacDougall, J D; Sale, D G

    1994-11-01

    The optimum pre-competition taper procedure for "strength athletes" is not known. We examined voluntary strength and evoked contractile properties of the elbow flexors over a 10 day rest only (ROT) and a 10 day reduced volume taper (RVT) in 8 resistance trained males (23 +/- 2.1 years). Following 3 wks of standardized training of the elbow flexors, subjects were randomly assigned to one of the tapers. Upon completion, they resumed training for 3 wks and completed the other taper. No arm training was performed during the ROT, while high intensity, low volume training was done every second day during the RVT. Maximum isometric (MVC), low (0.52 rad.s-1; LV) and high velocity (3.14 rad.s-1; HV) concentric peak torque, and evoked isometric twitch contractile properties were measured before and after each training phase and every 48 h during each taper. ANOVA comparison of the tapers revealed that MVC increased (p pre-taper values throughout the RVT (measurement days 2, 4, 6, 8 and 10), as did LV at 2, 4, 6, and 8 d. MVC did not change over the ROT but LV was significantly higher on day 2 and lower on days 8 and 10. LV was also greater on days 4, 6, 8 and 10 during the RVT compared to the ROT. The evoked contractile properties remained largely unchanged. The data indicate that resistance-trained athletes can improve low velocity concentric strength for at least 8 days by greatly reducing training volume, but maintaining training intensity.

  19. Radially polarized and passively Q-switched Yb-doped fiber laser based on intracavity birefringent mode discrimination

    Science.gov (United States)

    Sun, Xuehuan; Wu, Yongxiao; Chen, Sanbin; Li, Jianlang

    2018-05-01

    In this paper, we demonstrated a passive Q-switched ytterbium-doped fiber laser with radially polarized beam emission by using a c-cut YVO4 birefringent crystal as the intracavity polarization discriminator, and a Cr4+:YAG crystal as the saturable absorber and output coupler. The maximum averaged laser power reached 3.89 W with a high slope efficiency of 66.5%. The laser pulse had a peak power of 161 W, 160 ns duration, and 151 kHz repetition rate at the absorbed pump power of 6.48 W. Such a radially polarized pulse would facilitate numerous applications.

  20. Efficient high-peak-power and high-repetition-rate eye-safe laser using an intracavity KTP OPO

    International Nuclear Information System (INIS)

    Guo, J; Jiao, Z X; Wang, B; He, G Y

    2015-01-01

    An efficient high-peak-power and high-repetition-rate intracavity KTP optical parametric oscillator pumped by a Q-switched Nd:YVO 4 laser is demonstrated. We achieved 1.5 W output power of 1.5 μm at 10 kHz repetition rate with the pulse duration of 6 ns. The maximum peak power of 25 kW and the maximum pulse energy of 150 μJ have been obtained. The maximum conversion efficiency of 9.5% is achieved with respect to a laser diode power of 10.5 W. (paper)

  1. All-solid-state quasi-CW yellow laser with intracavity self-Raman conversion and sum frequency generation

    International Nuclear Information System (INIS)

    Kananovich, A; Grabtchikov, A; Orlovich, V; Demidovich, A; Danailov, M

    2010-01-01

    Quasi continuous-wave (qCW) yellow emission (pulse duration 5 ms, repetition rate 20 Hz) at 559 nm is demonstrated through intracavity sum frequency generation (SFG) of Stokes and fundamental fields in Nd:YVO 4 diode pumped self-Raman laser for the first time. Average in pulse output power at 559 nm was 0.47 W for 22 W of pump power, which corresponds to 2.1% of diode-to-yellow efficiency. The pulsed mode of operation was due to diode pump modulation and was used to reduce thermal stress of the crystal

  2. Modeling and multidimensional optimization of a tapered free electron laser

    Directory of Open Access Journals (Sweden)

    Y. Jiao

    2012-05-01

    Full Text Available Energy extraction efficiency of a free electron laser (FEL can be greatly increased using a tapered undulator and self-seeding. However, the extraction rate is limited by various effects that eventually lead to saturation of the peak intensity and power. To better understand these effects, we develop a model extending the Kroll-Morton-Rosenbluth, one-dimensional theory to include the physics of diffraction, optical guiding, and radially resolved particle trapping. The predictions of the model agree well with that of the GENESIS single-frequency numerical simulations. In particular, we discuss the evolution of the electron-radiation interaction along the tapered undulator and show that the decreasing of refractive guiding is the major cause of the efficiency reduction, particle detrapping, and then saturation of the radiation power. With this understanding, we develop a multidimensional optimization scheme based on GENESIS simulations to increase the energy extraction efficiency via an improved taper profile and variation in electron beam radius. We present optimization results for hard x-ray tapered FELs, and the dependence of the maximum extractable radiation power on various parameters of the initial electron beam, radiation field, and the undulator system. We also study the effect of the sideband growth in a tapered FEL. Such growth induces increased particle detrapping and thus decreased refractive guiding that together strongly limit the overall energy extraction efficiency.

  3. Combined tension and bending testing of tapered composite laminates

    Science.gov (United States)

    O'Brien, T. Kevin; Murri, Gretchen B.; Hagemeier, Rick; Rogers, Charles

    1994-11-01

    A simple beam element used at Bell Helicopter was incorporated in the Computational Mechanics Testbed (COMET) finite element code at the Langley Research Center (LaRC) to analyze the responce of tappered laminates typical of flexbeams in composite rotor hubs. This beam element incorporated the influence of membrane loads on the flexural response of the tapered laminate configurations modeled and tested in a combined axial tension and bending (ATB) hydraulic load frame designed and built at LaRC. The moments generated from the finite element model were used in a tapered laminated plate theory analysis to estimate axial stresses on the surface of the tapered laminates due to combined bending and tension loads. Surfaces strains were calculated and compared to surface strains measured using strain gages mounted along the laminate length. The strain distributions correlated reasonably well with the analysis. The analysis was then used to examine the surface strain distribution in a non-linear tapered laminate where a similarly good correlation was obtained. Results indicate that simple finite element beam models may be used to identify tapered laminate configurations best suited for simulating the response of a composite flexbeam in a full scale rotor hub.

  4. Preliminary Report of Carotid Artery Stenting Using a Tapered Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Chang Woo; Kim, Dong Hyun; Hong, Seung; Jeong; Kim, Young Suk; Byun, Joo Nam; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Ahn, Seong Hwan [Dept. of Neurology, Chosun University College of Medicine, Gwangju (Korea, Republic of)

    2011-10-15

    To analyze the results of carotid artery stenting using a tapered stent and to evaluate the effectiveness of the tapered stent compared to previously reported studies using non-tapered stents. From October 2008 to August 2010, elective carotid artery stenting using a tapered stent was attempted in 39 lesions from 36 consecutive patients. Post-procedural complications were evaluated by neurologic symptoms and magnetic resonance imaging. Restenosis or occlusion was evaluated by carotid Doppler ultrasound and computerized tomography with angiography. Newly developed neurologic symptoms were evaluated clinically. The self-expandable tapered stent was placed across the carotid artery stenosis. A total stroke was noted in 3 patients, while a major stroke was noted in 1 patient. On diffusion weighted imaging, new lesions were observed in 15 patients, but 13 patients were clinically silent. Follow-up imaging studies were performed in the 13 clinically silent lesions, and no evidence of restenosis or occlusion was found any of the 13 lesions. During clinical follow-up in 34 lesions from 31 patients, there were newly developed neurological symptoms in only 1 patient.

  5. Intracavity lavage and wound irrigation for prevention of surgical site infection

    Science.gov (United States)

    Norman, Gill; Atkinson, Ross A; Smith, Tanya A; Rowlands, Ceri; Rithalia, Amber D; Crosbie, Emma J; Dumville, Jo C

    2017-01-01

    Background Surgical site infections (SSIs) are wound infections that occur after an operative procedure. A preventable complication, they are costly and associated with poorer patient outcomes, increased mortality, morbidity and reoperation rates. Surgical wound irrigation is an intraoperative technique, which may reduce the rate of SSIs through removal of dead or damaged tissue, metabolic waste, and wound exudate. Irrigation can be undertaken prior to wound closure or postoperatively. Intracavity lavage is a similar technique used in operations that expose a bodily cavity; such as procedures on the abdominal cavity and during joint replacement surgery. Objectives To assess the effects of wound irrigation and intracavity lavage on the prevention of surgical site infection (SSI). Search methods In February 2017 we searched the Cochrane Wounds Specialised Register; the Cochrane Central Register of Controlled Trials (CENTRAL); Ovid MEDLINE; Ovid Embase and EBSCO CINAHL Plus. We also searched three clinical trials registries and references of included studies and relevant systematic reviews. There were no restrictions on language, date of publication or study setting. Selection criteria We included all randomised controlled trials (RCTs) of participants undergoing surgical procedures in which the use of a particular type of intraoperative washout (irrigation or lavage) was the only systematic difference between groups, and in which wounds underwent primary closure. The primary outcomes were SSI and wound dehiscence. Secondary outcomes were mortality, use of systemic antibiotics, antibiotic resistance, adverse events, re-intervention, length of hospital stay, and readmissions. Data collection and analysis Two review authors independently assessed studies for inclusion at each stage. Two review authors also undertook data extraction, assessment of risk of bias and GRADE assessment. We calculated risk ratios or differences in means with 95% confidence intervals where

  6. High-brightness tapered laser diodes with photonic crystal structures

    Science.gov (United States)

    Li, Yi; Du, Weichuan; Kun, Zhou; Gao, Songxin; Ma, Yi; Tang, Chun

    2018-02-01

    Beam quality of tapered laser diodes is limited by higher order lateral mode. On purpose of optimizing the brightness of tapered laser diodes, we developed a novel design of tapered diodes. This devices based on InGaAs/AlGaAs asymmetry epitaxial structure, containing higher order lateral mode filtering schemes especially photonic crystal structures, which fabricated cost effectively by using standard photolithography and dry etch processes. Meanwhile, the effects of photonic crystal structures on mode control are also investigated theoretically by FDBPM (Finite-Difference Beam Propagation Method) calculation. We achieved a CW optical output power of 6.9W at 940nm for a single emitter with 4 mm cavity length. A nearly diffraction limited beam of M2 ≍1.9 @ 0.5W has been demonstrated, and a highest brightness of β =75MW/(cm2 ·sr) was reached.

  7. Gap and channeled plasmons in tapered grooves: a review

    DEFF Research Database (Denmark)

    Smith, C. L. C.; Stenger, Nicolas; Kristensen, Anders

    2015-01-01

    Tapered metallic grooves have been shown to support plasmons - electromagnetically coupled oscillations of free electrons at metal-dielectric interfaces - across a variety of configurations and V-like profiles. Such plasmons may be divided into two categories: gap-surface plasmons (GSPs) that are......Tapered metallic grooves have been shown to support plasmons - electromagnetically coupled oscillations of free electrons at metal-dielectric interfaces - across a variety of configurations and V-like profiles. Such plasmons may be divided into two categories: gap-surface plasmons (GSPs...... platform to explore the fundamental science of plasmon excitations and their interactions. In this Review, we provide a research status update of plasmons in tapered grooves, starting with a presentation of the theory and important features of GSPs and CPPs, and follow with an overview of the broad range...

  8. Loss factor for short bunches in azimuthally symmetric tapered structures

    Directory of Open Access Journals (Sweden)

    A. Blednykh

    2010-06-01

    Full Text Available We use the program ECHO to study numerically the loss factor of axisymmetric cavities and collimators with and without tapering. We consider a Gaussian driving bunch of length σ, and structures with inner radius b, outer radius d, cavity gap (or collimator inner length g, and taper length L. In all cases we consider a short bunch with σ≪b. For the untapered structures (L=0, in certain regimes, we describe our numerical results using the known expressions for a step transition and for the diffraction model. In addition, we identify new regimes where gb, we present a phenomenological formula which accurately describes the dependence of the loss factor on the parameters σ, b, d, and L. This formula also holds for a tapered cavity with g>d^{2}/σ and d-b>b.

  9. Electromechanical modelling of tapered ionic polymer metal composites transducers

    Directory of Open Access Journals (Sweden)

    Rakesha Chandra Dash

    2016-09-01

    Full Text Available Ionic polymer metal composites (IPMCs are relatively new smart materials that exhibit a bidirectional electromechanical coupling. IPMCs have large number of important engineering applications such as micro robotics, biomedical devices, biomimetic robotics etc. This paper presents a comparison between tapered and uniform cantilevered Nafion based IPMCs transducer. Electromechanical modelling is done for the tapered beam. Thickness can be varied according to the requirement of force and deflection. Numerical results pertaining to the force and deflection characteristics of both type IPMCs transducer are obtained. It is shown that the desired amount of force and deflections for tapered IPMCs can be achieved for a given voltage. Different fixed end (t0 and free end (t1 thickness values have been taken to justify the results using MATLAB.

  10. Single muscle fiber gene expression with run taper.

    Directory of Open Access Journals (Sweden)

    Kevin Murach

    Full Text Available This study evaluated gene expression changes in gastrocnemius slow-twitch myosin heavy chain I (MHC I and fast-twitch (MHC IIa muscle fibers of collegiate cross-country runners (n = 6, 20±1 y, VO₂max = 70±1 ml•kg-1•min-1 during two distinct training phases. In a controlled environment, runners performed identical 8 kilometer runs (30:18±0:30 min:s, 89±1% HRmax while in heavy training (∼72 km/wk and following a 3 wk taper. Training volume during the taper leading into peak competition was reduced ∼50% which resulted in improved race times and greater cross-section and improved function of MHC IIa fibers. Single muscle fibers were isolated from pre and 4 hour post run biopsies in heavily trained and tapered states to examine the dynamic acute exercise response of the growth-related genes Fibroblast growth factor-inducible 14 (FN14, Myostatin (MSTN, Heat shock protein 72 (HSP72, Muscle ring-finger protein-1 (MURF1, Myogenic factor 6 (MRF4, and Insulin-like growth factor 1 (IGF1 via qPCR. FN14 increased 4.3-fold in MHC IIa fibers with exercise in the tapered state (P<0.05. MSTN was suppressed with exercise in both fiber types and training states (P<0.05 while MURF1 and HSP72 responded to running in MHC IIa and I fibers, respectively, regardless of training state (P<0.05. Robust induction of FN14 (previously shown to strongly correlate with hypertrophy and greater overall transcriptional flexibility with exercise in the tapered state provides an initial molecular basis for fast-twitch muscle fiber performance gains previously observed after taper in competitive endurance athletes.

  11. Tapered amplifier laser with frequency-shifted feedback

    Directory of Open Access Journals (Sweden)

    A. Bayerle, S. Tzanova, P. Vlaar, B. Pasquiou, F. Schreck

    2016-10-01

    Full Text Available We present a frequency-shifted feedback (FSF laser based on a tapered amplifier. The laser operates as a coherent broadband source with up to 370GHz spectral width and 2.3us coherence time. If the FSF laser is seeded by a continuous-wave laser a frequency comb spanning the output spectrum appears in addition to the broadband emission. The laser has an output power of 280mW and a center wavelength of 780nm. The ease and flexibility of use of tapered amplifiers makes our FSF laser attractive for a wide range of applications, especially in metrology.

  12. Optimization of Tapered Photonic Crystal Fibers for Blue-Enhanced Supercontinuum Generation

    DEFF Research Database (Denmark)

    Møller, Uffe; Sørensen, Simon Toft; Larsen, Casper

    2012-01-01

    Tapering of photonic crystal fibers is an effective way of shifting the dispersive wavelength edge of a supercontinuum spectrum down in the deep-blue. We discuss the optimum taper profile for blue-enhanced supercontinuum generation....

  13. The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments.

    Science.gov (United States)

    Özyürek, Taha; Yılmaz, Koray; Uslu, Gülşah

    2017-11-01

    It was aimed to compare the cyclic fatigue resistances of ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG) and the effects of sterilization by autoclave on the cyclic fatigue life of nickel-titanium (NiTi) instruments. Eighty PTU, 80 PTN, and 80 PTG were included to the present study. Files were tested in a simulated canal. Each brand of the NiTi files were divided into 4 subgroups: group 1, as received condition; group 2, pre-sterilized instruments exposed to 10 times sterilization by autoclave; group 3, instruments tested were sterilized after being exposed to 25%, 50%, and 75% of the mean cycles to failure, then cycled fatigue test was performed; group 4, instruments exposed to the same experiment with group 3 without sterilization. The number of cycles to failure (NCF) was calculated. The data was statistically analyzed by using one-way analysis of variance and post hoc Tukey tests. PTG showed significantly higher NCF than PTU and PTN in group 1 ( p Autoclaving increased the cyclic fatigue resistances of PTN and PTG.

  14. Coherent multi-octave spanning supercontinuum in tapered sulphide fibres

    DEFF Research Database (Denmark)

    Kubat, Irnis; Mägi, Eric; Hu, Tomonori

    A novel frequency comb design is proposed based on a newly developed ultrafast 3µm mid-infrared laser in conjunction with micro-taper chalcogenide fibre. The novel design allows for an all-fibre laser source yielding up to three octave coherent supercontinuum. The design is the first step in real...

  15. FDML swept source at 1060 nm using a tapered amplifier

    DEFF Research Database (Denmark)

    Marschall, Sebastian; Klein, Thomas; Wieser, Wolfgang

    2010-01-01

    We present a novel frequency-swept light source working at 1060nm that utilizes a tapered amplifier as gain medium. These devices feature significantly higher saturation power than conventional semiconductor optical amplifiers and can thus improve the limited output power of swept sources in this...... an axial resolution of 15 µm in air (~11µm in tissue) for OCT applications can be achieved....

  16. Tapered composite likelihood for spatial max-stable models

    KAUST Repository

    Sang, Huiyan

    2014-05-01

    Spatial extreme value analysis is useful to environmental studies, in which extreme value phenomena are of interest and meaningful spatial patterns can be discerned. Max-stable process models are able to describe such phenomena. This class of models is asymptotically justified to characterize the spatial dependence among extremes. However, likelihood inference is challenging for such models because their corresponding joint likelihood is unavailable and only bivariate or trivariate distributions are known. In this paper, we propose a tapered composite likelihood approach by utilizing lower dimensional marginal likelihoods for inference on parameters of various max-stable process models. We consider a weighting strategy based on a "taper range" to exclude distant pairs or triples. The "optimal taper range" is selected to maximize various measures of the Godambe information associated with the tapered composite likelihood function. This method substantially reduces the computational cost and improves the efficiency over equally weighted composite likelihood estimators. We illustrate its utility with simulation experiments and an analysis of rainfall data in Switzerland.

  17. Taper and volume equations for selected Appalachian hardwood species

    Science.gov (United States)

    A. Jeff Martin

    1981-01-01

    Coefficients for five taper/volume models are developed for 18 Appalachian hardwood species. Each model can be used to estimate diameter at any point on the bole, height to any preselected diameter, and cubic-foot volume between any two points on the bole. The resulting equations were tested on six sets of independent data and an evaluation of these tests is included,...

  18. Sensitive Leptospira DNA detection using tapered optical fiber sensor.

    Science.gov (United States)

    Zainuddin, Nurul H; Chee, Hui Y; Ahmad, Muhammad Z; Mahdi, Mohd A; Abu Bakar, Muhammad H; Yaacob, Mohd H

    2018-03-23

    This paper presents the development of tapered optical fiber sensor to detect a specific Leptospira bacteria DNA. The bacteria causes Leptospirosis, a deadly disease but with common early flu-like symptoms. Optical single mode fiber (SMF) of 125 μm diameter is tapered to produce 12 μm waist diameter and 15 cm length. The novel DNA-based optical fiber sensor is functionalized by incubating the tapered region with sodium hydroxide (NaOH), (3-Aminopropyl) triethoxysilane and glutaraldehyde. Probe DNA is immobilized onto the tapered region and subsequently hybridized by its complementary DNA (cDNA). The transmission spectra of the DNA-based optical fiber sensor are measured in the 1500 to 1600 nm wavelength range. It is discovered that the shift of the wavelength in the SMF sensor is linearly proportional with the increase in the cDNA concentrations from 0.1 to 1.0 nM. The sensitivity of the sensor toward DNA is measured to be 1.2862 nm/nM and able to detect as low as 0.1 fM. The sensor indicates high specificity when only minimal shift is detected for non-cDNA testing. The developed sensor is able to distinguish between actual DNA of Leptospira serovars (Canicola and Copenhageni) against Clostridium difficile (control sample) at very low (femtomolar) target concentrations. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Tapering of the CHESS-APS undulator: Results and modelling

    International Nuclear Information System (INIS)

    Lai, B.; Viccaro, P.J.; Dejus, R.; Gluskin, E.; Yun, W.B.; McNulty, I.; Henderson, C.; White, J.; Shen, Q.; Finkelstein, K.

    1992-01-01

    When the magnetic gap of an undulator is tapered along the beam direction, the slowly varying peak field B o introduces a spread in the value of the deflection parameter K. The result is a broad energy-band undulator that still maintains high degree of spatial collimation. These properties are very useful for EXAFS and energy dispersive techniques. We have characterized the CHESS-APS undulator (1 υ = 3.3cm) at one tapered configuration (10% change of the magnetic gap from one end of the undulator to the other). Spatial distribution and energy spectra of the first three harmonics through a pinhole were measured. The on-axis first harmonic width increased from 0.27 keV to 0.61 keV (FWHM) at the central energy of E 1 = 6.6 keV (K average = 0.69). Broadening in the angular distribution due to tapering was minimal. These results will be compared with computer modelling which simulates the actual electron trajectory in the tapered case

  20. How a dependent's variable non-randomness affects taper equation ...

    African Journals Online (AJOL)

    In order to apply the least squares method in regression analysis, the values of the dependent variable Y should be random. In an example of regression analysis linear and nonlinear taper equations, which estimate the diameter of the tree dhi at any height of the tree hi, were compared. For each tree the diameter at the ...

  1. Northeastern FIA Tree Taper Study: Current Status and Future Work

    Science.gov (United States)

    James A. Westfall; Charles T. Scott

    2005-01-01

    The northeastern unit of the Forest Inventory and Analysis program (NE-FIA) is engaged in an ongoing project to develop regionwide tree taper equations. Sampling intensity is based on NE-FIA plot data and is stratified by species, diameter class, and height class. To date, modeling research has been aimed largely at evaluating existing model forms (and hybrids thereof...

  2. Gaussian Filtering with Tapered Oil-Filled Photonic Bandgap Fibers

    DEFF Research Database (Denmark)

    Brunetti, Anna Chiara; Scolari, Lara; Weirich, Johannes

    2008-01-01

    A tunable Gaussian filter based on a tapered oil-filled photonic crystal fiber is demonstrated. The filter is centered at X=1364nm with a bandwidth (FWHM) of 237nm. Tunability is achieved by changing the temperature of the filter. A shift of 210nm of the central wavelength has been observed...

  3. Power dependence of supercontinuum noise in uniform and tapered PCFs

    DEFF Research Database (Denmark)

    Møller, Uffe; Sørensen, Simon Toft; Jakobsen, C.

    2012-01-01

    We experimentally investigate the noise properties of picosecond supercontinuum spectra generated at different power levels in uniform and tapered photonic crystal fibers. We show that the noise at the spectral edges of the generated supercontinuum is at a constant level independent on the pump...

  4. 77 FR 50716 - Tapered Roller Bearings From China

    Science.gov (United States)

    2012-08-22

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-344 (Third Review)] Tapered Roller..., the United States International Trade Commission (Commission) determines, pursuant to section 751(c... notice in the Office of the Secretary, U.S. International Trade Commission, Washington, DC, and by...

  5. Optical localization of quantum dots in tapered nanowires

    DEFF Research Database (Denmark)

    Østerkryger, Andreas Dyhl; Gregersen, Niels; Fons, Romain

    2017-01-01

    In this work we have measured the far-field emission patterns of In As quantum dots embedded in a GaAs tapered nanowire and used an open-geometry Fourier modal method for determining the radial position of the quantum dots by computing the far-field emission pattern for different quantum dot...

  6. Theoretical Analysis and Preparation of Tapered Suspended Core Microstructure Fibers

    Czech Academy of Sciences Publication Activity Database

    Martan, Tomáš; Kaňka, Jiří; Kašík, Ivan; Matějec, Vlastimil

    2009-01-01

    Roč. 3, č. 3 (2009), s. 233-249 ISSN 1559-9612 Institutional research plan: CEZ:AV0Z20670512 Keywords : tapered fibers * optical sensors Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.354, year: 2009

  7. Linearly tapered slot antenna circular array for mobile communications

    Science.gov (United States)

    Simons, Rainee N.; Kelly, Eron; Lee, Richard Q.; Taub, Susan R.

    1993-01-01

    The design, fabrication and testing of a conformal K-band circular array is presented. The array consists of sixteen linearly tapered slot antennas (LTSA). It is fed by a 1:16 microstrip line power splitter via electromagnetic coupling. The array has an omni-directional pattern in the azimuth plane. In the elevation plane the beam is displaced above the horizon.

  8. Tapered composite likelihood for spatial max-stable models

    KAUST Repository

    Sang, Huiyan; Genton, Marc G.

    2014-01-01

    Spatial extreme value analysis is useful to environmental studies, in which extreme value phenomena are of interest and meaningful spatial patterns can be discerned. Max-stable process models are able to describe such phenomena. This class of models is asymptotically justified to characterize the spatial dependence among extremes. However, likelihood inference is challenging for such models because their corresponding joint likelihood is unavailable and only bivariate or trivariate distributions are known. In this paper, we propose a tapered composite likelihood approach by utilizing lower dimensional marginal likelihoods for inference on parameters of various max-stable process models. We consider a weighting strategy based on a "taper range" to exclude distant pairs or triples. The "optimal taper range" is selected to maximize various measures of the Godambe information associated with the tapered composite likelihood function. This method substantially reduces the computational cost and improves the efficiency over equally weighted composite likelihood estimators. We illustrate its utility with simulation experiments and an analysis of rainfall data in Switzerland.

  9. Drug taper during long-term video-EEG monitoring

    DEFF Research Database (Denmark)

    Guld, A. T.; Sabers, A.; Kjaer, T. W.

    2017-01-01

    Objectives: Anti-epileptic drugs (AED) are often tapered to reduce the time needed to record a sufficient number of seizure during long-term video-EEG monitoring (LTM). Fast AED reduction is considered less safe, but few studies have examined this. Our goal is to examine whether the rate of AED r...

  10. Structural Analysis of Taper-Threaded Rebar Couplers

    International Nuclear Information System (INIS)

    Chu, Seok Jae; Kwon, Hyuk Mo; Seo, Sang Hwan

    2014-01-01

    A number of rebar couplers were developed by the leading companies. The information about the products is available from the company website. However, the theory on the taper-threaded coupler is not available. In this paper, the mechanics of the taper-thread was developed to understand the effect of the tightening torque. Structural analysis of our own newly developed rebar coupler was done to improve the strength of the coupler. The taper-threaded rebar coupler was analyzed. The tightening of the rebar into the coupler developed a circumferential stress in the coupler. The circumferential stress depends on the coefficient of friction as well as the tightening torque. The circumferential stress is less than the allowable stress 20 kgf/mm 2 of the material for the coefficient of friction greater than 0.1. The tightening of the rebar into the coupler and the subsequent tensioning was simulated using CATIA. Linear elastic analysis considering contact was done. The tightening of the taper-threaded rebar developed a uniform stress distribution in both standard coupler and position coupler. On the other hand, the tightening of the nut in the axial direction developed a non-uniform stress distribution. Similarly the tensioning also developed a non-uniform stress distribution

  11. Characterization of tapered polymer optical fibers under side illumination for fluorescence sensing applications

    Science.gov (United States)

    Pulido, C.; Esteban, Ó.

    2011-05-01

    In this work we present the fabrication and characterization of tapered polymer fibers used as fluorescence based sensors with a side-illumination arrangement. The fabrication method consists of a travelling-heater that gives a tight control of the tapered fibers parameters, namely the taper waist and the profile of the transition length between the unaltered fiber and the taper waist. Furthermore, a different approach for using fluorophores in fluorescence based sensors has been developed. With our method, we can locally introduce a fluorescent dye inside the taper region, which could lead to the generation of cuasi-distributed sensors for lengths of hundred of meters.

  12. Less Is More: The Physiological Basis for Tapering in Endurance, Strength, and Power Athletes

    Directory of Open Access Journals (Sweden)

    Kevin A. Murach

    2015-08-01

    Full Text Available Taper, or reduced-volume training, improves competition performance across a broad spectrum of exercise modes and populations. This article aims to highlight the physiological mechanisms, namely in skeletal muscle, by which taper improves performance and provide a practical literature-based rationale for implementing taper in varied athletic disciplines. Special attention will be paid to strength- and power-oriented athletes as taper is under-studied and often overlooked in these populations. Tapering can best be summarized by the adage “less is more” because maintained intensity and reduced volume prior to competition yields significant performance benefits.

  13. Deep-blue supercontinnum sources with optimum taper profiles – verification of GAM

    DEFF Research Database (Denmark)

    Sørensen, Simon Toft; Møller, Uffe; Larsen, Casper

    2012-01-01

    We use an asymmetric 2 m draw-tower photonic crystal fiber taper to demonstrate that the taper profile needs careful optimisation if you want to develop a supercontinuum light source with as much power as possible in the blue edge of the spectrum. In particular we show, that for a given taper...... length, the downtapering should be as long as possible. We argue how this may be explained by the concept of group-acceleration mismatch (GAM) and we confirm the results using conventional symmetrical short tapers made on a taper station, which have varying downtapering lengths....

  14. Refractive index sensors based on the fused tapered special multi-mode fiber

    Science.gov (United States)

    Fu, Xing-hu; Xiu, Yan-li; Liu, Qin; Xie, Hai-yang; Yang, Chuan-qing; Zhang, Shun-yang; Fu, Guang-wei; Bi, Wei-hong

    2016-01-01

    In this paper, a novel refractive index (RI) sensor is proposed based on the fused tapered special multi-mode fiber (SMMF). Firstly, a section of SMMF is spliced between two single-mode fibers (SMFs). Then, the SMMF is processed by a fused tapering machine, and a tapered fiber structure is fabricated. Finally, a fused tapered SMMF sensor is obtained for measuring external RI. The RI sensing mechanism of tapered SMMF sensor is analyzed in detail. For different fused tapering lengths, the experimental results show that the RI sensitivity can be up to 444.517 81 nm/RIU in the RI range of 1.334 9—1.347 0. The RI sensitivity is increased with the increase of fused tapering length. Moreover, it has many advantages, including high sensitivity, compact structure, fast response and wide application range. So it can be used to measure the solution concentration in the fields of biochemistry, health care and food processing.

  15. Efficient continuous-wave eye-safe region signal output from intra-cavity singly resonant optical parametric oscillator

    International Nuclear Information System (INIS)

    Li Bin; Ding Xin; Sheng Quan; Yin Su-Jia; Shi Chun-Peng; Li Xue; Wen Wu-Qi; Yao Jian-Quan; Yu Xuan-Yi

    2012-01-01

    We report an efficient continuous-wave (CW) tunable intra-cavity singly resonant optical parametric oscillator based on the multi-period periodically poled lithium niobate and using a laser diode (LD) end-pumped CW 1064 nm Nd:YVO 4 laser as the pump source. A highly efficiency CW operation is realized through a careful cavity design for mode matching and thermal stability. The signal tuning range is 1401–1500 nm obtained by varying the domain period. The maximum output power of 2.2 W at 1500 nm is obtained with a 17.1 W 808 nm LD power and the corresponding conversion efficiency is 12.9%. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  16. Intracavity Cr3+:LiCAF + PPSLT optical parametric oscillator with self-injection-locked pump wave

    International Nuclear Information System (INIS)

    Maestre, H; Torregrosa, A J; Capmany, J

    2013-01-01

    In this letter we present an intracavity pumped continuous wave (CW) doubly resonant optical parametric oscillator (OPO) based on Cr 3+ :LiCaAlF 6 (Cr:LiCAF) as the material generating the OPO pump wave and periodically poled stoichiometric lithium tantalate (PPSLT) as the nonlinear material. The OPO pump wave is spectrally narrowed and tuned by means of an external cavity, thus allowing self-injection locking of the OPO pump wavelength. When operated near degeneracy, the constructed OPO enables a fast tuning of the parametrically generated wavelengths in response to small perturbations of the phase-matching condition. The Cr:LiCAF emission band is especially well suited to provide dual-wavelength oscillation in the optical communications 1550 nm band as a result of the parametric oscillation in PPSLT. (letter)

  17. A New Damped and Tapered Accelerating Structure for CLIC

    CERN Document Server

    Raguin, J Y; Syratchev, I V; Wilson, Ian H; Wuensch, Walter

    2002-01-01

    The main performance limits when designing accelerating structures for the Compact Linear Collider (CLIC) for an average accelerating gradient above 100 MV/m are electrical breakdown and material fatigue caused by pulsed surface heating. In addition, for stable beam operation, the structures should have low short-range transverse wakefields and much-reduced transverse and longitudinal long-range wakefields. Two damped and tapered accelerating structures have been designed. The first has an accelerating gradient of 112 MV/m with the surface electrical field limited to 300 MV/m and the maximum temperature increase limited to 100°C. The second, with an accelerating gradient of 150 MV/m, has a peak surface electrical field of 392 MV/m and a maximum temperature increase of 167°C. Innovations to the cell and damping waveguide geometry and to the tapering of the structures are presented, and possible further improvements are proposed.

  18. Shape matters: improved flight in tapered auto-rotating wings

    Science.gov (United States)

    Liu, Yucen; Vincent, Lionel; Kanso, Eva

    2017-11-01

    Many plants use gravity and wind to disperse their seeds. The shape of seed pods influence their aerodynamics. For example, Liana seeds form aerodynamic gliders and Sycamore trees release airborne ``helicopters.'' Here, we use carefully-controlled experiments and high-speed photography to examine dispersion by tumbling (auto-rotation) and we focus on the effect of geometry on flight characteristics. We consider four families of shapes: rectangular, elliptic, tapered, and sharp-tip wings, and we vary the span-to-chord ratio. We find that tapered wings exhibit extended flight time and range, that is, better performance. A quasi-steady two-dimensional model is used to highlight the mechanisms by which shape affects flight performance. These findings could have significant implications on linking seedpod designs to seed dispersion patterns as well as on optimizing wing design in active flight problems.

  19. Coherent beam combining architectures for high power tapered laser arrays

    Science.gov (United States)

    Schimmel, G.; Janicot, S.; Hanna, M.; Decker, J.; Crump, P.; Erbert, G.; Witte, U.; Traub, M.; Georges, P.; Lucas-Leclin, G.

    2017-02-01

    Coherent beam combining (CBC) aims at increasing the spatial brightness of lasers. It consists in maintaining a constant phase relationship between different emitters, in order to combine them constructively in one single beam. We have investigated the CBC of an array of five individually-addressable high-power tapered laser diodes at λ = 976 nm, in two architectures: the first one utilizes the self-organization of the lasers in an interferometric extended-cavity, which ensures their mutual coherence; the second one relies on the injection of the emitters by a single-frequency laser diode. In both cases, the coherent combining of the phase-locked beams is ensured on the front side of the array by a transmission diffractive grating with 98% efficiency. The passive phase-locking of the laser bar is obtained up to 5 A (per emitter). An optimization algorithm is implemented to find the proper currents in the five ridge sections that ensured the maximum combined power on the front side. Under these conditions we achieve a maximum combined power of 7.5 W. In the active MOPA configuration, we can increase the currents in the tapered sections up to 6 A and get a combined power of 11.5 W, corresponding to a combining efficiency of 76%. It is limited by the beam quality of the tapered emitters and by fast phase fluctuations between emitters. Still, these results confirm the potential of CBC approaches with tapered lasers to provide a high-power and high-brightness beam, and compare with the current state-of-the-art with laser diodes.

  20. Plasmonic Sensors Based on Doubly-Deposited Tapered Optical Fibers

    Directory of Open Access Journals (Sweden)

    Agustín González-Cano

    2014-03-01

    Full Text Available A review of the surface plasmon resonance (SPR transducers based on tapered fibers that have been developed in the last years is presented. The devices have proved their good performance (specifically, in terms of sensitivity and their versatility and they are a very good option to be considered as basis for any kind of chemical and biological sensor. The technology has now reached its maturity and here we summarize some of the characteristics of the devices produced.

  1. Pulse propagation in tapered wiggler free electron lasers

    International Nuclear Information System (INIS)

    Goldstein, J.C.; Colson, W.B.

    1981-01-01

    The one-dimensional theory of short pulse propagation in free electron lasers is extended to tapered wiggler devices and is used to study the behavior of an oscillator with parameter values close to those expected in forthcoming experiments. It is found that stable laser output is possible only over a small range of optical cavity lengths. Optical pulse characteristcs are presented and are found to change considerably over this range

  2. Fibre Optic Sensors Using Adiabatically Tapered Single Mode Fibres

    Science.gov (United States)

    1994-02-01

    molecules were then coupled hack into the fundamental guided mode of the taper. The level of these emissions was characterised by using a monochromati’r...y y y Pae Ps4 Pase4 Pasc4_ Pase4jPase4 _Pasc4 I pase Plate 3: Can be the bof~tom of Plate 1 after it has been read. P7 28 29 3 31 1 32 PB I PG PG G2 P

  3. Where science meets practice: Olympic coaches' crafting of the tapering process.

    Science.gov (United States)

    Ritchie, Darren; Allen, Justine B; Kirkland, Andrew

    2018-05-01

    Although there is research providing physiologically-based guidance for the content of the taper, this study was the first to examine how coaches actually implement the taper. The purpose of this study was to examine the taper planning and implementation processes of successful Olympic coaches leading up to major competitions and how they learned about tapering. Seven track and field coaches participated in semi-structured interviews exploring their tapering processes. To be considered for inclusion, coaches were required to have coached one or more athletes to an Olympic or Paralympic medal. Through a process of axial and open coding interview transcripts were analysed and lower and higher order themes developed describing the coaches' tapering processes. Our findings indicate that the strategies employed to achieve the desired physiological adaptions of the taper were consistent with research (e.g., reduction in volume whilst maintaining intensity and frequency). However, our findings also suggest that tapering is far from a straight forward "textbook" process. The taper was not restricted to physiological outcomes with coaches considering athletes' psychological as well as physical state. Coaches also involved the athlete in the process, adapted the taper to the athlete, continually monitored its progress, and adapted it further as required.

  4. Portable fiber-optic taper coupled optical microscopy platform

    Science.gov (United States)

    Wang, Weiming; Yu, Yan; Huang, Hui; Ou, Jinping

    2017-04-01

    The optical fiber taper coupled with CMOS has advantages of high sensitivity, compact structure and low distortion in the imaging platform. So it is widely used in low light, high speed and X-ray imaging systems. In the meanwhile, the peculiarity of the coupled structure can meet the needs of the demand in microscopy imaging. Toward this end, we developed a microscopic imaging platform based on the coupling of cellphone camera module and fiber optic taper for the measurement of the human blood samples and ascaris lumbricoides. The platform, weighing 70 grams, is based on the existing camera module of the smartphone and a fiber-optic array which providing a magnification factor of 6x.The top facet of the taper, on which samples are placed, serves as an irregular sampling grid for contact imaging. The magnified images of the sample, located on the bottom facet of the fiber, are then projected onto the CMOS sensor. This paper introduces the portable medical imaging system based on the optical fiber coupling with CMOS, and theoretically analyzes the feasibility of the system. The image data and process results either can be stored on the memory or transmitted to the remote medical institutions for the telemedicine. We validate the performance of this cell-phone based microscopy platform using human blood samples and test target, achieving comparable results to a standard bench-top microscope.

  5. FDM Analysis for Blood Flow through Stenosed Tapered Arteries

    Directory of Open Access Journals (Sweden)

    Sankar DS

    2010-01-01

    Full Text Available Abstract A computational model is developed to analyze the unsteady flow of blood through stenosed tapered narrow arteries, treating blood as a two-fluid model with the suspension of all the erythrocytes in the core region as Herschel-Bulkley fluid and the plasma in the peripheral layer as Newtonian fluid. The finite difference method is employed to solve the resulting system of nonlinear partial differential equations. The effects of stenosis height, peripheral layer thickness, yield stress, viscosity ratio, angle of tapering and power law index on the velocity, wall shear stress, flow rate and the longitudinal impedance are analyzed. It is found that the velocity and flow rate increase with the increase of the peripheral layer thickness and decrease with the increase of the angle of tapering and depth of the stenosis. It is observed that the flow rate decreases nonlinearly with the increase of the viscosity ratio and yield stress. The estimates of the increase in the longitudinal impedance to flow are considerably lower for the two-fluid Herschel-Bulkley model compared with those of the single-fluid Herschel-Bulkley model. Hence, it is concluded that the presence of the peripheral layer helps in the functioning of the diseased arterial system.

  6. Simultaneous Q-switching and mode-locking in an intracavity frequency doubled diode-pumped Nd:YVO4 / KTP green laser with Cr4+:YAG

    International Nuclear Information System (INIS)

    Mukhopadhyay, P. K.; Ranganathan, K.; George, J.; Nathan, T. P. S.; Alsous, M. B.

    2007-01-01

    We report intracavity second harmonic (at 532 nm) generation in passively Q-switched mode-locked Nd: YVO4 laser. The width of a typical Q-switched envelope of the mode locked pulses for the green laser was around 65 ± 5 ns and the repetition rate for the mode locked pulses was 400 MHz. The intracavity frequency doubling significantly improves the depth of modulation of the mode locked pulses. The peak power of a single mode locked green pulse near the center of the Q-switched envelope was estimated to be more than 2kw and the average green power was 6 times higher than the CW green power at an incident diode pump power of 6W. (author)

  7. High-Efficiency Intracavity Continuous-Wave Green-Light Generation by Quasiphase Matching in a Bulk Periodically Poled MgO:LiNbO3 Crystal

    Directory of Open Access Journals (Sweden)

    Shaowei Chu

    2008-01-01

    Full Text Available 908 mW of green light at 532 nm were generated by intracavity quasiphase matching in a bulk periodically poled MgO:LiNbO3 (PPMgLN crystal. A maximum optical-to-optical conversion efficiency of 33.5% was obtained from a 0.5 mm thick, 10 mm long, and 5 mol% MgO:LiNbO3 crystal with an end-pump power of 2.7 W at 808 nm. The temperature bandwidth between the intracavity and single-pass frequency doubling was found to be different for the PPMgLN. Reliability and stability of the green laser were evaluated. It was found that for continuous operation of 100 hours, the output stability was better than 97.5% and no optical damage was observed.

  8. Analysis of Surface Characteristics of ProTaper Universal and ProTaper Next Instruments by Scanning Electron Microscopy.

    Science.gov (United States)

    Bennett, Jeffery; Chung, Kwok-Hung; Fong, Hanson; Johnson, James; Paranjpe, Avina

    2017-07-01

    Many new rotary files systems have been introduced, however, limited research has been conducted related to the surface irregularities of these files and if these have any effects on the files themselves. Hence, the aim of the present study was to analyze surface irregularities of the ProTaper® Universal rotary files (PTU) and the ProTaper Next™ rotary files (PTN) before and after instrumentation in curved canals. The main objective was to investigate the nature of these irregularities and how they might influence the use and fracture of rotary files during root-canal treatments. The files were examined pre-operatively using a stereomicroscope and scanning electron microscopy(SEM) to analyze surface imperfections and the presence of particles. Mesial roots of forty extracted mandibular molars were selected. Each instrument was used to prepare one of the mesial canals. The files were then rinsed with alcohol, and autoclaved and analyzed again. Of the 80 files used in this study, five files fractured, five files unwound and seven files were curved or bent and they all belonged to the PTU group. Irregularities and debris could be visualized with the SEM on both unused PTU and PTN files. Most of the debris was found associated with deeper milling grooves and defects on the surface of the metal. Surface analysis of the files that were used and sterilized were performed and the SEM images demonstrated organic debris, metal flash, and crack formation and initiation of fractures for both file types. All files showed machining grooves, metal flash, debris, and defects on cutting edges. These irregularities appear to be critical in the accumulation of debris and initiation of fatigue and crack propagation within the NiTi alloy. The accumulation of debris could be a concern due to the potential exchange of organic debris between patients. Key words: ProTaper® Universal, ProTaper Next™, surface characteristics, SEM.

  9. Demonstration of a III-nitride vertical-cavity surface-emitting laser with a III-nitride tunnel junction intracavity contact

    International Nuclear Information System (INIS)

    Leonard, J. T.; Young, E. C.; Yonkee, B. P.; Cohen, D. A.; Margalith, T.; Speck, J. S.; DenBaars, S. P.; Nakamura, S.

    2015-01-01

    We report on a III-nitride vertical-cavity surface-emitting laser (VCSEL) with a III-nitride tunnel junction (TJ) intracavity contact. The violet nonpolar VCSEL employing the TJ is compared to an equivalent VCSEL with a tin-doped indium oxide (ITO) intracavity contact. The TJ VCSEL shows a threshold current density (J th ) of ∼3.5 kA/cm 2 , compared to the ITO VCSEL J th of 8 kA/cm 2 . The differential efficiency of the TJ VCSEL is also observed to be significantly higher than that of the ITO VCSEL, reaching a peak power of ∼550 μW, compared to ∼80 μW for the ITO VCSEL. Both VCSELs display filamentary lasing in the current aperture, which we believe to be predominantly a result of local variations in contact resistance, which may induce local variations in refractive index and free carrier absorption. Beyond the analyses of the lasing characteristics, we discuss the molecular-beam epitaxy (MBE) regrowth of the TJ, as well as its unexpected performance based on band-diagram simulations. Furthermore, we investigate the intrinsic advantages of using a TJ intracavity contact in a VCSEL using a 1D mode profile analysis to approximate the threshold modal gain and general loss contributions in the TJ and ITO VCSEL

  10. Demonstration of a III-nitride vertical-cavity surface-emitting laser with a III-nitride tunnel junction intracavity contact

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, J. T., E-mail: jtleona01@gmail.com; Young, E. C.; Yonkee, B. P.; Cohen, D. A.; Margalith, T.; Speck, J. S. [Materials Department, University of California, Santa Barbara, California 93106 (United States); DenBaars, S. P.; Nakamura, S. [Materials Department, University of California, Santa Barbara, California 93106 (United States); Department of Electrical and Computer Engineering, University of California, Santa Barbara, California 93106 (United States)

    2015-08-31

    We report on a III-nitride vertical-cavity surface-emitting laser (VCSEL) with a III-nitride tunnel junction (TJ) intracavity contact. The violet nonpolar VCSEL employing the TJ is compared to an equivalent VCSEL with a tin-doped indium oxide (ITO) intracavity contact. The TJ VCSEL shows a threshold current density (J{sub th}) of ∼3.5 kA/cm{sup 2}, compared to the ITO VCSEL J{sub th} of 8 kA/cm{sup 2}. The differential efficiency of the TJ VCSEL is also observed to be significantly higher than that of the ITO VCSEL, reaching a peak power of ∼550 μW, compared to ∼80 μW for the ITO VCSEL. Both VCSELs display filamentary lasing in the current aperture, which we believe to be predominantly a result of local variations in contact resistance, which may induce local variations in refractive index and free carrier absorption. Beyond the analyses of the lasing characteristics, we discuss the molecular-beam epitaxy (MBE) regrowth of the TJ, as well as its unexpected performance based on band-diagram simulations. Furthermore, we investigate the intrinsic advantages of using a TJ intracavity contact in a VCSEL using a 1D mode profile analysis to approximate the threshold modal gain and general loss contributions in the TJ and ITO VCSEL.

  11. STIR-Physics: Cold Atoms and Nanocrystals in Tapered Nanofiber and High-Q Resonator Potentials

    Science.gov (United States)

    2016-11-02

    STIR- Physics : Cold Atoms and Nanocrystals in Tapered Nanofiber and High-Q Resonator Potentials We worked on a tapered fiber in cold atomic cloud...reviewed journals: Number of Papers published in non peer-reviewed journals: Final Report: STIR- Physics : Cold Atoms and Nanocrystals in Tapered Nanofiber...other than abstracts): Number of Peer-Reviewed Conference Proceeding publications (other than abstracts): Books Number of Manuscripts: 0.00Number of

  12. Dwarf mistletoe does not increase trunk taper in released red firs in California

    Science.gov (United States)

    Robert F. Scharpf

    1977-01-01

    Dwarf mistletoe had no noticeable effect on trunk taper of young, dominant and codominant red firs 4 to 22 inches (10.2 to 55.9 cm) d.b.h. Also, taper was not influenced by live crown ratio of infected and uninfected trees. Trees less than 7 inches d.b.h. had significantly more taper than larger trees, irrespective of dwarf mistletoe.

  13. The Effect of Vibration Characteristics on the Atomization Rate in a Micro-Tapered Aperture Atomizer

    OpenAIRE

    Qiufeng Yan; Jianhui Zhang; Jun Huang; Ying Wang

    2018-01-01

    Because little is known about the atomization theory of a micro-tapered aperture atomizer, we investigated the vibration characteristics of this type of atomizer. The atomization mechanism of a micro-tapered aperture atomizer was described, and the atomization rate equation was deduced. As observed via microscopy, the angle of the micro-tapered aperture changes with the applied voltage, which proved the existence of a dynamic cone angle. The forward and reverse atomization rates were measured...

  14. An evaluation of .06 tapered gutta-percha cones for filling of .06 taper prepared curved root canals.

    Science.gov (United States)

    Gordon, M P J; Love, R M; Chandler, N P

    2005-02-01

    To compare the area occupied by gutta-percha, sealer, or void in standardized .06 tapered prepared simulated curved canals and in mesio-buccal canals of extracted maxillary first molars filled with a single .06 gutta-percha point and sealer or lateral condensation of multiple .02 gutta-percha points and sealer. Simulated canals in resin blocks with either a 30 degrees curve and radius of 10.5 mm (n = 20) or a 58 degrees curve and 4.7 mm radius (n = 20) and curved mesio-buccal canals of extracted maxillary first molars (n = 20) were prepared using .06 ProFiles in a variable tip crown-down sequence to an apical size 35 at 0.5 mm from the canal terminus or apical foramen. Ten 30 degrees and 58 degrees curved resin canals and 10 canals in the extracted teeth group were obturated with .02 taper gutta-percha cones and AH 26 sealer using lateral condensation. The time required to obturate was recorded. The remaining canals were obturated with a single .06 taper gutta-percha cone and AH 26 sealer. Excess gutta-percha was removed from the specimens using heat and the warm mass vertically condensed. Horizontal sections were cut at 0.5, 1.5, 2.5, 4.5, 7.5 and 11.5 mm from the canal terminus or apical foramen. Colour photographs were taken using an Olympus 35 mm camera attached to a stereomicroscope set at x40 magnification, and then digitized using a flatbed scanner. The cross-sectional area of the canal contents was analysed using Adobe PhotoShop. The percentage of gutta-percha, sealer or voids to the total root canal area were derived and data analysed using unpaired Student's t-test and the Mann-Whitney U-test. In the 30 degrees curved canals the levels had between 94 and 100% of the area filled with gutta-percha with no significant difference (P > 0.05) between the lateral condensation and single cone techniques. In the 58 degrees curved canals the levels had 92-99% of the area filled with gutta-percha, with the single cone technique having significantly (P 0.05) between

  15. Ultra-low loss nano-taper coupler for Silicon-on-Insulator ridge waveguide

    DEFF Research Database (Denmark)

    Pu, Minhao; Liu, Liu; Ou, Haiyan

    2010-01-01

    A nano-taper coupler is optimized specially for the transverse-magnetic mode for interfacing light between a silicon-on-insulator ridge waveguide and a single-mode fiber. An ultra-low coupling loss of ~0.36dB is achieved for the nano-taper coupler.......A nano-taper coupler is optimized specially for the transverse-magnetic mode for interfacing light between a silicon-on-insulator ridge waveguide and a single-mode fiber. An ultra-low coupling loss of ~0.36dB is achieved for the nano-taper coupler....

  16. Effects of type of tapering on anaerobic capacity in young basketball players

    Directory of Open Access Journals (Sweden)

    Hugo Augusto Alvares da Silva Lira

    2017-11-01

    Full Text Available The aim of this study was to analyze the effect of the type of tapering on anaerobic capacity in male young basketball players. This was an experimental research with 12 weeks, developed with 47 basketball players, randomly divided into three groups: linear tapering (LG, tapering by step (SG and control group (CG. All groups participated of the same planning training until the last three weeks of periodization (the tapering phase. Only the CG did not perform tapering. Anaerobic Running Speed Test was carried in the last week of each mesocycle to assess the anaerobic capacity. The findings revealed that anaerobic capacity attenuated from the competitive to tapering phase in LG (p= .01 and SG (p= .01, which was not verified for the CG (p= .29. Significant difference of anaerobic capacity was found between LG and CG (p= .01, SG and CG (p= .01 and between LG and SG (p= .04 in the tapering phase. It was concluded that the tapering strategies were efficient to maximize anaerobic capacity in young basketball players, although linear tapering strategy has been revealed the best strategy for improvement the anaerobic capacity.

  17. Effect of tapering on anaerobic power and capacity of tae-kwon-do athletes

    Directory of Open Access Journals (Sweden)

    Leonardo de Sousa Fortes

    2017-05-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2017v19n2p224   The aim of the study was to analyze the effect of a tapering period on anaerobic power and capacity of tae-kwon-do athletes. Thirty-one male tae-kwon-do participants of the Brazilian Championship were selected in a non-probabilistic way. Subjects were randomly divided into two groups, namely: experimental group (EG, n = 15 and control group (CG, n = 17. Both groups followed the same training protocol up to the tapering stage. CG was submitted to training loads contained in the last two weeks of the macrocycle. Only EG was submitted to tapering. Tapering had 2 weeks duration, adopting the linear tapering method. Taekwondo Anaerobic Test was performed by athletes before the start of the season, which was named as pre-intervention, and the last week of each mesocycle [Prep I, Prep II and Tapering (only EG]. Group vs. time effect interaction (p < 0.01 was identified for alactic anaerobic power, with an increase only in EG in tapering (p = 0.01. A significant group vs. time interaction (p <0.01 was revealed to fatigue index, improved anaerobic capacity being checked in EG only after the tapering period (p = 0.01. It was concluded that two weeks of linear type tapering optimized the anaerobic power and capacity of male tae-kwon-do athletes.

  18. Tapering and discontinuation of methadone for chronic pain.

    Science.gov (United States)

    Breivik, Harald

    2015-06-01

    How to taper and discontinue methadone therapy for chronic pain management is illustrated through a case report. This report is adapted from paineurope 2014; Issue 4, ©Haymarket Medical Publications Ltd, and is presented with permission. paineurope is provided as a service to pain management by Mundipharma International, LTD and is distributed free of charge to healthcare professionals in Europe. Archival issues can be viewed via the website: www.paineurope.com at which health professionals can find links to the original articles and request copies of the quarterly publication and access additional pain education and pain management resources.

  19. Fabrication and a Study on the Tapered Scintillator Radiation Sensors

    International Nuclear Information System (INIS)

    Kim, Gye Hong

    2003-02-01

    Optical fibers have been investigated for their uses as sensor materials in various nuclear applications. Comprehensive overviews of their potential usages in nuclear environments can be found in the literatures. Optical fibers with doped scintillating elements in the core have drawn special interests as nuclear radiation detectors. The two important functions of a scintillating optical fiber, as a radiation detector, are scintillator (light emitter) and light transmitter. When radiation interacts with the core material, scintillation occurs and resultant lights are transmitted through the fiber to an opto-electronic device such as a photomultiplier tube. Optical fiber sensors have several advantages as compared to other sensors of conventional material. Since they do not require electric power in the sensor part, they are less susceptible to trouble in harsh environments such as underground or underwater. At relatively low cost a multi-point distributed radiation monitoring system could be made using the fiber sensors. Furthermore, unlike the conventional scintillating counters they are not influenced by any magnetic field surrounding them. This study has been conducted to investigate the feasibility of using scintillating optical fibers for the detection of gamma rays emitted by 137 Cs. Several types of gamma-ray sensors have been constructed by packing different numbers of fibers into aluminum tubes, and tested to detect the 137 Cs gamma ray. During the study it has been found that a tapered fibers might be more efficient to collect the lights produced inside the sensor and transfer them into the transmitting fiber. In order to investigate the effectiveness of the tapered fiber, tapered plastic scintillators, composed of polystyrene with minute amount of dPOPOP and PPO or bPBD, have been fabricated and tested for the detection of gamma rays from 1.0, 1.5, 3.0 and 5.0 μCi 137 Cs sources. The pulse height spectra and the relationship between the radioactivity and

  20. Design and Manufacture of Structurally Efficient Tapered Struts

    Science.gov (United States)

    Brewster, Jebediah W.

    2009-01-01

    Composite materials offer the potential of weight savings for numerous spacecraft and aircraft applications. A composite strut is just one integral part of the node-to-node system and the optimization of the shut and node assembly is needed to take full advantage of the benefit of composites materials. Lockheed Martin designed and manufactured a very light weight one piece composite tapered strut that is fully representative of a full scale flight article. In addition, the team designed and built a prototype of the node and end fitting system that will effectively integrate and work with the full scale flight articles.

  1. Spectral purity and tunability of terahertz quantum cascade laser sources based on intracavity difference-frequency generation.

    Science.gov (United States)

    Consolino, Luigi; Jung, Seungyong; Campa, Annamaria; De Regis, Michele; Pal, Shovon; Kim, Jae Hyun; Fujita, Kazuue; Ito, Akio; Hitaka, Masahiro; Bartalini, Saverio; De Natale, Paolo; Belkin, Mikhail A; Vitiello, Miriam Serena

    2017-09-01

    Terahertz sources based on intracavity difference-frequency generation in mid-infrared quantum cascade lasers (THz DFG-QCLs) have recently emerged as the first monolithic electrically pumped semiconductor sources capable of operating at room temperature across the 1- to 6-THz range. Despite tremendous progress in power output, which now exceeds 1 mW in pulsed and 10 μW in continuous-wave regimes at room temperature, knowledge of the major figure of merits of these devices for high-precision spectroscopy, such as spectral purity and absolute frequency tunability, is still lacking. By exploiting a metrological grade system comprising a terahertz frequency comb synthesizer, we measure, for the first time, the free-running emission linewidth (LW), the tuning characteristics, and the absolute center frequency of individual emission lines of these sources with an uncertainty of 4 × 10 -10 . The unveiled emission LW (400 kHz at 1-ms integration time) indicates that DFG-QCLs are well suited to operate as local oscillators and to be used for a variety of metrological, spectroscopic, communication, and imaging applications that require narrow-LW THz sources.

  2. Intra-cavity upconversion to 631 nm of images illuminated by an eye-safe ASE source at 1550 nm.

    Science.gov (United States)

    Torregrosa, A J; Maestre, H; Capmany, J

    2015-11-15

    We report an image wavelength upconversion system. The system mixes an incoming image at around 1550 nm (eye-safe region) illuminated by an amplified spontaneous emission (ASE) fiber source with a Gaussian beam at 1064 nm generated in a continuous-wave diode-pumped Nd(3+):GdVO(4) laser. Mixing takes place in a periodically poled lithium niobate (PPLN) crystal placed intra-cavity. The upconverted image obtained by sum-frequency mixing falls around the 631 nm red spectral region, well within the spectral response of standard silicon focal plane array bi-dimensional sensors, commonly used in charge-coupled device (CCD) or complementary metal-oxide-semiconductor (CMOS) video cameras, and of most image intensifiers. The use of ASE illumination benefits from a noticeable increase in the field of view (FOV) that can be upconverted with regard to using coherent laser illumination. The upconverted power allows us to capture real-time video in a standard nonintensified CCD camera.

  3. Plasma diagnosis by dye laser intracavity absorption: Final report for period January 1, 1982-May 31, 1986

    International Nuclear Information System (INIS)

    Brink, G.O.

    1986-05-01

    Dye laser intracavity absorption (ICA) has been studied as a potential diagnostic for plasma or neutral beam systems. For magnetic field measurements it is necessary to make Zeeman effect measurements on the resonance transition of atomic lithium on a millisecond time scale, or to make motional Stark Effect measurements on an injected fast atomic beam of hydrogen. To do this it may be necessary to sweep the dye laser in wavelength at a rapid rate so that the absorber can be sampled many times during the measurement. We have examined both of these possibilities during this contract. A rather detailed absorption spectrum of molecular hydrogen and deuterium arising in the 2c 3 Piu and other electronic states has been obtained and analyzed. This has provided new information on the types of molecular species that may be detected in a plasma by ICA, and may provide a basis for the application of ICA for the diagnosis of the edge plasma in a tokamak or in the end regions of a mirror machine

  4. The taper of cast post preparation measured using innovative image processing technique

    Directory of Open Access Journals (Sweden)

    Al Hyiasat Ahmad S

    2010-08-01

    Full Text Available Abstract Background No documentation in the literature about taper of cast posts. This study was conducted to measure the degree of cast posts taper, and to evaluate its suitability based on the anatomy aspects of the common candidate teeth for post reconstruction. Methods Working casts for cast posts, prepared using Gates Glidden drills, were collected. Impressions of post spaces were made using polyvinyl siloxan putty/wash technique. Digital camera with a 10' high quality lens was used for capturing two digital images for each impression; one in the Facio-Lingual (FL and the other in the Mesio-Distal (MD directions. Automated image processing program was developed to measure the degree of canal taper. Data were analyzed using Statistical Package for Social Sciences software and One way Analysis of Variance. Results Eighty four dies for cast posts were collected: 16 for each maxillary anterior teeth subgroup, and 18 for each maxillary and mandibular premolar subgroup. Mean of total taper for all preparations was 10.7 degree. There were no statistical differences among the total taper of all groups (P = .256 or between the MD and FL taper for each subgroup. Mean FL taper for the maxillary first premolars was lower significantly (P = .003 than the maxillary FL taper of the second premolars. FL taper was higher than the MD taper in all teeth except the maxillary first premolars. Conclusions Taper produced did not reflect the differences among the anatomy of teeth. While this technique deemed satisfactory in the maxillary anterior teeth, the same could not be said for the maxillary first premolars. Careful attention to the root anatomy is mandatory.

  5. B1 gradient coherence selection using a tapered stripline.

    Science.gov (United States)

    van Meerten, S G J; Tijssen, K C H; van Bentum, P J M; Kentgens, A P M

    2018-01-01

    Pulsed-field gradients are common in modern liquid state NMR pulse sequences. They are often used instead of phase cycles for the selection of coherence pathways, thereby decreasing the time required for the NMR experiment. Soft off-resonance pulses with a B 1 gradient result in a spatial encoding similar to that created by pulsed-field (B 0 ) gradients. In this manuscript we show that pulse sequences with pulsed-field gradients can easily be converted to one which uses off-resonance B 1 field gradient (OFFBEAT) pulses. The advantage of B 1 gradient pulses for coherence selection is that the chemical shift evolution during the pulses is (partially) suppressed. Therefore no refocusing echos are required to correct for evolution during the gradient pulses. A tapered stripline is shown to be a convenient tool for creating a well-defined gradient in the B 1 field strength. B 1 gradient coherence selection using a tapered stripline is a simple and cheap alternative to B 0 pulsed-field gradients. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Apically-extruded debris using the ProTaper system.

    Science.gov (United States)

    Azar, Nasim Gheshlaghi; Ebrahimi, Gholamreza

    2005-04-01

    The purpose of this in vitro study was to determine the quantity of debris and irrigant extruded apically using the ProTaper system compared to ProFiles and K-Flexofiles. Thirty-six mesio-buccal root canals of human mandibular molars were selected and divided into three groups of twelve canals. Two groups were instrumented with ProFiles and ProTapers according to the manufacturer's instructions. The other group was instrumented with K-Flexofiles using the step-back technique. A standard amount of irrigant was used for each canal. Apically-extruded debris and irrigant was collected in pre-weighed vials. The mean weight of extruded debris and irrigant for each group was statistically analysed using Student's t-test and one-way ANOVA. All instrumentation techniques produced extruded debris and irrigant. Although the mean amount of extrusion with the step-back technique was higher than the two rotary systems, there was no significant difference between the three groups (p > 0.05). NiTi rotary systems were associated with less apical extrusion, but were not significantly better than hand file instrumentation. All techniques extruded debris.

  7. Ultra-Abrupt Tapered Fiber Mach-Zehnder Interferometer Sensors

    Directory of Open Access Journals (Sweden)

    Lanying Zhou

    2011-05-01

    Full Text Available A fiber inline Mach-Zehnder interferometer (MZI consisting of ultra-abrupt fiber tapers was fabricated through a new fusion-splicing method. By fusion-splicing, the taper diameter-length ratio is around 1:1, which is much greater than those (1:10 made by stretching. The proposed fabrication method is very low cost, 1/20–1/50 of those of LPFG pair MZI sensors. The fabricated MZIs are applied to measure refractive index, temperature and rotation angle changes. The temperature sensitivity of the MZI at a length of 30 mm is 0.061 nm/°C from 30–350 °C. The proposed MZI is also used to measure rotation angles ranging from 0° to 0.55°; the sensitivity is 54.98 nm/°. The refractive index sensitivity is improved by 3–5 fold by fabricating an inline micro–trench on the fiber cladding using a femtosecond laser. Acetone vapor of 50 ppm in N2 is tested by the MZI sensor coated with MFI–type zeolite thin film. The proposed MZI sensors are capable of in situ detection in many areas of interest such as environmental management, industrial process control, and public health.

  8. Strain-induced bi-thermoelectricity in tapered carbon nanotubes

    Science.gov (United States)

    Algharagholy, L. A. A.; Pope, T.; Lambert, C. J.

    2018-03-01

    We show that carbon-based nanostructured materials are a novel testbed for controlling thermoelectricity and have the potential to underpin the development of new cost-effective environmentally-friendly thermoelectric materials. In single-molecule junctions, it is known that transport resonances associated with the discrete molecular levels play a key role in the thermoelectric performance, but such resonances have not been exploited in carbon nanotubes (CNTs). Here we study junctions formed from tapered CNTs and demonstrate that such structures possess transport resonances near the Fermi level, whose energetic location can be varied by applying strain, resulting in an ability to tune the sign of their Seebeck coefficient. These results reveal that tapered CNTs form a new class of bi-thermoelectric materials, exhibiting both positive and negative thermopower. This ability to change the sign of the Seebeck coefficient allows the thermovoltage in carbon-based thermoelectric devices to be boosted by placing CNTs with alternating-sign Seebeck coefficients in tandem.

  9. Fatigue Life Analysis of Tapered Hybrid Composite Flexbeams

    Science.gov (United States)

    Murri, Gretchen B.; Schaff, Jeffery R.; Dobyns, Alan L.

    2002-01-01

    Nonlinear-tapered flexbeam laminates from a full-size composite helicopter rotor hub flexbeam were tested under combined constant axial tension and cyclic bending loads. The two different graphite/glass hybrid configurations tested under cyclic loading failed by delamination in the tapered region. A 2-D finite element model was developed which closely approximated the flexbeam geometry, boundary conditions, and loading. The analysis results from two geometrically nonlinear finite element codes, ANSYS and ABAQUS, are presented and compared. Strain energy release rates (G) obtained from the above codes using the virtual crack closure technique (VCCT) at a resin crack location in the flexbeams are presented for both hybrid material types. These results compare well with each other and suggest that the initial delamination growth from the resin crack toward the thick region of the flexbeam is strongly mode II. The peak calculated G values were used with material characterization data to calculate fatigue life curves and compared with test data. A curve relating maximum surface strain to number of loading cycles at delamination onset compared reasonably well with the test results.

  10. Fatigue Life Methodology for Tapered Hybrid Composite Flexbeams

    Science.gov (United States)

    urri, Gretchen B.; Schaff, Jeffery R.

    2006-01-01

    Nonlinear-tapered flexbeam specimens from a full-size composite helicopter rotor hub flexbeam were tested under combined constant axial tension and cyclic bending loads. Two different graphite/glass hybrid configurations tested under cyclic loading failed by delamination in the tapered region. A 2-D finite element model was developed which closely approximated the flexbeam geometry, boundary conditions, and loading. The analysis results from two geometrically nonlinear finite element codes, ANSYS and ABAQUS, are presented and compared. Strain energy release rates (G) associated with simulated delamination growth in the flexbeams are presented from both codes. These results compare well with each other and suggest that the initial delamination growth from the tip of the ply-drop toward the thick region of the flexbeam is strongly mode II. The peak calculated G values were used with material characterization data to calculate fatigue life curves for comparison with test data. A curve relating maximum surface strain to number of loading cycles at delamination onset compared well with the test results.

  11. Spectral narrowing of a 980 nm tapered diode laser bar

    Science.gov (United States)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Lucas Leclin, Ga"lle; Petersen, Paul Michael; Thestrup, Birgitte

    2011-03-01

    High power diode laser bars are interesting in many applications such as solid state laser pumping, material processing, laser trapping, laser cooling and second harmonic generation. Often, the free running laser bars emit a broad spectrum of the order of several nanometres which limit their scope in wavelength specific applications and hence, it is vital to stabilize the emission spectrum of these devices. In our experiment, we describe the wavelength narrowing of a 12 element 980 nm tapered diode laser bar using a simple Littman configuration. The tapered laser bar which suffered from a big smile has been "smile corrected" using individual phase masks for each emitter. The external cavity consists of the laser bar, both fast and slow axis micro collimators, smile correcting phase mask, 6.5x beam expanding lens combination, a 1200 lines/mm reflecting grating with 85% efficiency in the first order, a slow axis focusing cylindrical lens of 40 mm focal length and an output coupler which is 10% reflective. In the free running mode, the laser emission spectrum was 5.5 nm wide at an operating current of 30A. The output power was measured to be in excess of 12W. Under the external cavity operation, the wavelength spread of the laser could be limited to 0.04 nm with an output power in excess of 8 W at an operating current of 30A. The spectrum was found to be tuneable in a range of 16 nm.

  12. Low insertion loss SOI microring resonator integrated with nano-taper couplers

    DEFF Research Database (Denmark)

    Pu, Minhao; Frandsen, Lars Hagedorn; Ou, Haiyan

    2009-01-01

    We demonstrate a microring resonator working at TM mode integrated with nano-taper couplers with 3.6dB total insertion loss. The measured insertion loss of the nano-taper coupler was only 1.3dB for TM mode....

  13. Tapering off benzodiazepines in long-term users : an economic evaluation

    NARCIS (Netherlands)

    Oude Voshaar, Richard C; Krabbe, Paul F M; Gorgels, Wim J M J; Adang, Eddy M M; van Balkom, Anton J L M; van de Lisdonk, Eloy H; Zitman, Frans G

    2006-01-01

    BACKGROUND: Discontinuation of benzodiazepine usage has never been evaluated in economic terms. This study aimed to compare the relative costs and outcomes of tapering off long-term benzodiazepine use combined with group cognitive behavioural therapy (TO+CBT), tapering off alone (TOA) and usual

  14. FINITE ELEMENT ANALYSIS OF TAPERED COMPOSITE PLATE GIRDER WITH A NON-LINEAR VARYING WEB DEPTH

    Directory of Open Access Journals (Sweden)

    Q. A. HASAN

    2017-11-01

    Full Text Available The paper presents Finite Element Analysis to determine the ultimate shear capacity of tapered composite plate girder. The effect of degree of taper on the ultimate shear capacity of tapered steel-concrete composite plate girder with a nonlinear varying web depth, effect of slenderness ratio on the ultimate shear capacity, and effect of flange stiffness on the ductility were considered as the parametric studies. Effect of concrete slab on the ultimate shear capacity of tapered plate girders was also considered and it was found to be so effective on the ultimate shear capacity of the tapered plate girder compared with the steel one. The accuracy of the finite element method is established by comparing the finite element with the results existing in the literature. The study was conducted using nonlinear finite element modelling with computer software LUSAS 14.7.

  15. Supercontinuum generation from 437 to 2850 nm in a tapered fluorotellurite microstructured fiber

    Science.gov (United States)

    Wang, F.; Jia, Z. X.; Yao, C. F.; Wang, S. B.; Hu, M. L.; Wu, C. F.; Ohishi, Y.; Qin, W. P.; Qin, G. S.

    2016-12-01

    We demonstrated supercontinuum (SC) generation in a tapered fluorotellurite microstructured fiber (MF) with a sub-micrometer core diameter. Fluorotellurite MFs based on TeO2-BaF2-Y2O3 glasses were fabricated by using a rod-in-tube method and a tapered fluorotellurite MF with a minimum core diameter of ~0.65 µm was prepared by employing a tapering system. A 1560 nm femtosecond fiber laser was used as the pumping source. With increasing the peak power of the launched pump laser to ~11 kW, SC light expanding from 437 to 2850 nm was generated in the tapered fluorotellurite MF. In addition, relatively strong blue-shifted dispersive wave at ~489 nm was also observed from the tapered fluorotellurite MF.

  16. Effect of length/width ratio of tapered beams on the performance of piezoelectric energy harvesters

    International Nuclear Information System (INIS)

    Matova, S P; Renaud, M; Jambunathan, M; Goedbloed, M; Van Schaijk, R

    2013-01-01

    Tapering of the beams as a way to increase the generated output power of cantilever piezoelectric energy harvesters has gained popularity in recent years. The tapering increases the average strain in the beam and consequently the charge generated by the piezoelectric material. Different authors claim an improvement of up to 30% in the generated output power. We have investigated the possibility of using tapered beams in MEMS piezoelectric energy harvesters. Numerical simulations did not suggest any increase in the generated output power and the lack of improvement was confirmed in practice. With the help of the numerical simulations it was further found that the tapering does work but only for certain design configurations, namely for cantilevers with long slender beams. For cantilevers with short wide beams, the tapering has no significant effect on the output power of the harvester. (paper)

  17. Comparison of debris extruded apically and working time used by ProTaper Universal rotary and ProTaper retreatment system during gutta-percha removal

    Directory of Open Access Journals (Sweden)

    Mary Kinue Nakamune Uezu

    2010-12-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the in vitro action of ProTaper retreatment files and ProTaper Universal in the retreatment of mandibular premolars. MATERIAL AND METHODS: The amount of debris extruded apically was measured and the time to reach the working length and to complete the removal of gutta-percha was observed. Thirty teeth had their canals prepared using ProTaper Universal files and were obturated by the single cone technique. The teeth were then stored at 37ºC in a humid environment for 7 days. During the use of the rotary instruments for root canal filling removal, the apical portions of the teeth were attached to the open end of a resin tube to collect the apically extruded debris. RESULTS: ProTaper Universal files were significantly faster (p=0.0011 than the ProTaper retreatment files to perform gutta-percha removal, but no significant difference was found between the files regarding the time to reach the working length or the amount of apical extrusion. CONCLUSIONS: ProTaper Universal rotary had better results for endodontic retreatment, and both techniques promote similar apical extrusion of debris.

  18. Comparative evaluation of apically extruded debris with V-Taper, ProTaper Next, and the Self-adjusting File systems.

    Science.gov (United States)

    Vyavahare, Nishant K; Raghavendra, Srinidhi Surya; Desai, Niranjan N

    2016-01-01

    Complete cleaning of the root canal is the goal for ensuring success in endodontics. Removal of debris plays an important role in achieving this goal. In spite of advancements in instrument design, apical extrusion of debris remains a source of inflammation in the periradicular region. To comparatively evaluate the amount of apically extruded debris with V-Taper, ProTaper Next, and the self-adjusting File (SAF) system. Sixty-four extracted human mandibular teeth with straight root canals were taken. Access openings were done and working length determined. The samples were randomly divided into three groups: Group I - V-Taper files (n = 20), Group II - ProTaper Next (n = 20), Group III - SAF (n = 20). Biomechanical preparation was completed and the debris collected in vials to be quantitatively determined. The data obtained was statistically analyzed using ANOVA and post hoc Tukey's test. All the specimens showed apical debris extrusion. SAF showed significantly less debris extrusion compared to V-Taper and ProTaper Next (P endodontic instruments. This indicates that the incidence of inter-treatment flare-ups due to debris extrusion would be less with the SAF.

  19. Asymmetric Draw-Tower Tapers for Supercontinuum Generation and Verification of the Novel Concept of Group-Acceleration Matching

    DEFF Research Database (Denmark)

    Sørensen, Simon Toft; Møller, Uffe; Moselund, P. M.

    2012-01-01

    We present the first short asymmetrical draw-tower photonic crystal fiber taper for maximizing the power in the blue edge of a supercontinuum. The results clearly emphasize the importance of the taper shape on the spectrum.......We present the first short asymmetrical draw-tower photonic crystal fiber taper for maximizing the power in the blue edge of a supercontinuum. The results clearly emphasize the importance of the taper shape on the spectrum....

  20. Monolithic integration of collimating Fresnel lens for beam quality enhancement in tapered high-power laser diode

    NARCIS (Netherlands)

    Lau, F.K.; Tee, C.W.; Zhao, Xin; Williams, K.A.; Penty, R.V.; White, I.H.; Calligaro, M.; Lecomte, M.; Parillaud, O.; Michel, N.; Krakowski, M.

    2006-01-01

    We demonstrate, for the first time, a monolithic integrated lens for wide aperture gain-guided tapered laser beam quality enhancement by compensating the quadratic phase curvature. The 3mm long tapered laser with an output aperture of 170µm adopted in this design consists of a gain-guided tapered

  1. Design and Development of Intracavity Optical Parametric Oscillator-based Eye Safe Laser Operating at 20 Hz without Forced Air Cooling

    OpenAIRE

    Atul Bhardwaj; Lalita Agrawal; A. K. Maini

    2013-01-01

    In this paper we report the design and development of an electro-optically Q-switched diode pumped Nd:YAG laser with intracavity optical parametric oscillator, generating ~ 5 ns laser pulses of ~8 mJ energy at eye safe wavelength of 1534 nm. A Z-shaped laser resonator has been designed with porro prism end reflector in Q-switch arm containing RTP Q-Switch and a suitably oriented waveplate. The gain arm consists of a Ø3 x 72 mm Nd: YAG laser rod, pumped from one side by 3 x 5 bar laser diode a...

  2. Intracavity quasi-phase-matched self-frequency conversion in a periodically poled Nd:Mg:LiNbO3 crystal

    International Nuclear Information System (INIS)

    Laptev, G D; Novikov, Aleksei A

    2001-01-01

    The theory of intracavity quasi-phase-matched self-frequency conversion in an active nonlinear periodically poled structure is developed. The processes of quasi-phase-matched self-frequency doubling, self-halving and mixing using the pump wave in a periodically poled Nd:Mg:LiNbO 3 crystal are studied. The dependences of the efficiency of nonlinear optical conversion in these processes on the reflection coefficient of the output mirror and on linear losses in the medium are investigated. (nonlinear optical phenomena)

  3. Study of the field-sequential modulation of Nd:YVO4/MgO:PPLN based intra-cavity frequency doubling green laser

    Science.gov (United States)

    Zhang, Bin; Gan, Yi; Xu, Chang-Qing

    2018-06-01

    The field sequential modulation of a Nd:YVO4/MgO:PPLN intra-cavity, frequency doubling green laser was studied. The modulation frequency was set at 1 kHz and the duty cycle was changed from 20% to CW operation. It was shown that the quasi-phase matched (QPM) temperature decreases with an increase of the modulation duty cycle, and in turn causing the peak efficiency to rise. It was found that the temperature change in MgO:PPLN and the thermal lens effect in Nd:YVO4 crystal were the respective origins of these observed experimental phenomena.

  4. Tapered whiskers are required for active tactile sensation.

    Science.gov (United States)

    Hires, Samuel Andrew; Pammer, Lorenz; Svoboda, Karel; Golomb, David

    2013-11-19

    Many mammals forage and burrow in dark constrained spaces. Touch through facial whiskers is important during these activities, but the close quarters makes whisker deployment challenging. The diverse shapes of facial whiskers reflect distinct ecological niches. Rodent whiskers are conical, often with a remarkably linear taper. Here we use theoretical and experimental methods to analyze interactions of mouse whiskers with objects. When pushed into objects, conical whiskers suddenly slip at a critical angle. In contrast, cylindrical whiskers do not slip for biologically plausible movements. Conical whiskers sweep across objects and textures in characteristic sequences of brief sticks and slips, which provide information about the tactile world. In contrast, cylindrical whiskers stick and remain stuck, even when sweeping across fine textures. Thus the conical whisker structure is adaptive for sensor mobility in constrained environments and in feature extraction during active haptic exploration of objects and surfaces. DOI: http://dx.doi.org/10.7554/eLife.01350.001.

  5. Growth strategies to control tapering in Ge nanowires

    Directory of Open Access Journals (Sweden)

    P. Periwal

    2014-04-01

    Full Text Available We report the effect of PH3 on the morphology of Au catalyzed Ge nanowires (NWs. Ge NWs were grown on Si (111 substrate at 400 °C in the presence of PH3, using vapor-liquid-solid method by chemical vapor deposition. We show that high PH3/GeH4 ratio causes passivation at NW surface. At high PH3 concentration phosphorous atoms attach itself on NW surface and form a self-protection coating that prevents conformal growth and leads to taper free nanostructures. However, in case of low PH3 flux the combination of axial and radial growth mechanism occurs resulting in conical structure. We have also investigated axial PH3-intrinsic junctions in Ge NWs. The unusual NW shape is attributed to a combination of catalyzed, uncatalyzed and diffusion induced growth.

  6. A New Stem Taper Function for Short-rotation poplar

    Energy Technology Data Exchange (ETDEWEB)

    Benbrahim, Mohammed [INRA Centre de Bordeaux, Cestas (France). Unite de Recherches Forestieres; Gavaland, Andre [INRA Centre de Toulouse, Castanet-Tolosane (France). Unite Agroforesterie et Foret Paysanne

    2003-07-01

    A new stem taper function was established for individual trees of two poplar hybrid clones grown on a short-rotation coppice. The model could be easily fitted and required three parameters to be estimated. It can be used to estimate both diameter at a given height and height for a given top diameter. Two of the three parameters controlled the conical and the neiloid parts of the stem. Significant differences in these parameters were observed between the two clones even if no differences were observed for diameter at breast height or total height of the stem. The model could not be integrated to calculate volumes (total volume, merchantable volume), which were estimated by numerical integration. However, use of this new model allows the optimal length of billets to be determined and thus maximizes the merchantable biomass of poplar in short-rotation coppice by minimizing the biomass of residues.

  7. Tapered Polymer Fiber Sensors for Reinforced Concrete Beam Vibration Detection.

    Science.gov (United States)

    Luo, Dong; Ibrahim, Zainah; Ma, Jianxun; Ismail, Zubaidah; Iseley, David Thomas

    2016-12-16

    In this study, tapered polymer fiber sensors (TPFSs) have been employed to detect the vibration of a reinforced concrete beam (RC beam). The sensing principle was based on transmission modes theory. The natural frequency of an RC beam was theoretically analyzed. Experiments were carried out with sensors mounted on the surface or embedded in the RC beam. Vibration detection results agreed well with Kistler accelerometers. The experimental results found that both the accelerometer and TPFS detected the natural frequency function of a vibrated RC beam well. The mode shapes of the RC beam were also found by using the TPFSs. The proposed vibration detection method provides a cost-comparable solution for a structural health monitoring (SHM) system in civil engineering.

  8. Tapered joint design for power transmission of MW-grade wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Jong Hun; Bae, Jun Woo; Oh, Han Yong [Dept. of Mechatronics, Jungwon University, Geosan (Korea, Republic of); Kwon, Yong Chul [Kyeongnam Technopark, Changwon (Korea, Republic of)

    2015-11-15

    This study focuses on the design of the tapered joints of a wind power turbine. The main variables of the tapered joint are the transmitted torque, shaft diameter, contact area of the tapered ring, and tightening torque of the bolts, which applies a compressive pressure from the hub to the shaft. The stress distribution of the taper fit was calculated under axisymmetric plane strain conditions because of the small taper angle. The axial displacement of the clamp can be calculated from the radial elastic deformation and the taper angle. The stress field of each ring is obtained from the cylinder stress equation. To verify the accuracy of the calculation, finite element (FE) analysis was performed, and the results of the calculation and FE analysis were compared. The hoop stress of the tapered surface showed a discrepancy of approximately 10, but the trends of the stress distributions of each component and the relative movement obtained by FE analysis were in good agreement with the analytical calculation results.

  9. Endodontic Shaping Performance Using Nickel–Titanium Hand and Motor ProTaper Systems by Novice Dental Students

    Directory of Open Access Journals (Sweden)

    Ming-Gene Tu

    2008-05-01

    Conclusion: These findings show that the novice students prepared the simulated curved canal that deviated more outwardly from apical 1 mm to 4 mm using the hand ProTaper. The ability to maintain the original curvature was better in the motor rotary ProTaper group than in the hand ProTaper group. Undergraduate students, if following the preparation sequence carefully, could successfully perform canal shaping by motor ProTaper files and achieve better root canal geometry than by using hand ProTaper files within the same teaching and practicing sessions.

  10. Modern trunnions are more flexible: a mechanical analysis of THA taper designs.

    Science.gov (United States)

    Porter, David A; Urban, Robert M; Jacobs, Joshua J; Gilbert, Jeremy L; Rodriguez, José A; Cooper, H John

    2014-12-01

    There is renewed concern surrounding the potential for corrosion at the modular head-neck junction to cause early failure in contemporary THAs. Although taper corrosion involves a complex interplay of many factors, a previous study suggested that a decrease in flexural rigidity of the femoral trunnion may be associated with an increased likelihood of corrosion at retrieval. By analyzing a large revision retrieval database of femoral stems released during a span of three decades, we asked: (1) how much does flexural rigidity vary among different taper designs; (2) what is the contribution of taper geometry alone to flexural rigidity of the femoral trunnion; and (3) how have flexural rigidity and taper length changed with time in this group of revised retrievals? A dual-center retrieval analysis of 85 modular femoral stems released between 1983 and 2012 was performed, and the flexural rigidity and length of the femoral trunnions were determined. These stems were implanted between 1991 and 2012 and retrieved at revision or removal surgery between 2004 and 2012. There were 10 different taper designs made from five different metal alloys from 16 manufacturers. Digital calipers were used to measure taper geometries by two independent observers. Median flexural rigidity was 228 N-m(2); however, there was a wide range of values among the various stems spanning nearly an order of magnitude between the most flexible (80 N-m(2)) and most rigid (623 N-m(2)) trunnions, which was partly attributable to the taper geometry and to the material properties of the base alloy. There was a negative correlation between flexural rigidity and length of the trunnion and release date of the stem. There is wide variability in flexural rigidity of various taper designs, with a trend toward trunnions becoming shorter and less rigid with time. This temporal trend may partly explain why taper corrosion is being seen with increasing frequency in modern THAs.

  11. Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses.

    Science.gov (United States)

    Witt, Florian; Gührs, Julian; Morlock, Michael M; Bishop, Nicholas E

    2015-01-01

    Corrosion of modular taper junctions of hip implants may be associated with clinical failure. Taper design parameters, as well as the intraoperatively applied assembly forces, have been proposed to affect corrosion. Fretting corrosion is related to relative interface shear motion and fluid ingress, which may vary with contact force and area. It was hypothesised in this study that assembly forces modify the extent and distribution of the surface contact area at the taper interface between a cobalt chrome head and titanium stem taper with a standard threaded surface profile. Local abrasion of a thin gold coating applied to the stem taper prior to assembly was used to determine the contact area after disassembly. Profilometry was then used to assess permanent deformation of the stem taper surface profile. With increasing assembly force (500 N, 2000 N, 4000 N and 8000 N) the number of stem taper surface profile ridges in contact with the head taper was found to increase (9.2±9.3%, 65.4±10.8%, 92.8±6.0% and 100%) and the overall taper area in contact was also found to increase (0.6±0.7%, 5.5±1.0%, 9.9±1.1% and 16.1±0.9%). Contact was inconsistently distributed over the length of the taper. An increase in plastic radial deformation of the surface ridges (-0.05±0.14 μm, 0.1±0.14 μm, 0.21±0.22 μm and 0.96±0.25 μm) was also observed with increasing assembly force. The limited contact of the taper surface ridges at lower assembly forces may influence corrosion rates, suggesting that the magnitude of the assembly force may affect clinical outcome. The method presented provides a simple and practical assessment of the contact area at the taper interface.

  12. Vector rectangular-shape laser based on reduced graphene oxide interacting with a long fiber taper.

    Science.gov (United States)

    Gao, Lei; Zhu, Tao; Huang, Wei; Zeng, Jing

    2014-10-01

    A vector dual-wavelength rectangular-shape laser (RSL) based on a long fiber taper deposited with reduced graphene oxide is proposed, where nonlinearity is enhanced due to a large evanescent-field-interacting length and strong field confinement of an 8 mm fiber taper with a waist diameter of 4 μm. Graphene flakes are deposited uniformly on the taper waist with light pressure effect, so this structure guarantees both excellent saturable absorption and high nonlinearity. The RSL with a repetition rate of 7.9 MHz shows fast polarization switching in two orthogonal polarization directions, and temporal and spectral characteristics are investigated.

  13. Spectral beam combining of a 980 nm tapered diode laser bar

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Ostendorf, Ralf

    2010-01-01

    We demonstrate spectral beam combining of a 980 nm tapered diode laser bar. The combined beam from 12 tapered emitters on the bar yielded an output power of 9.3 W at 30 A of operating current. An M2 value of 5.3 has been achieved along the slow axis. This value is close to that of a free running...... single tapered emitter on the bar at the same current level. The overall spectral beam combining efficiency was measured to be 63%....

  14. Transmission of fast highly charged ions through straight and tapered glass capillaries

    International Nuclear Information System (INIS)

    Ayyad, Asma M; Keerthisinghe, D; Kayani, A; Tanis, J A; Dassanayake, B S; Ikeda, T

    2013-01-01

    The transmission of 1 and 3 MeV protons through a borosilicate straight glass capillary and a tapered glass capillary was investigated. The straight capillary had a diameter of ∼0.18 mm and a length of ∼14.4 mm, while the tapered capillary had an inlet diameter of ∼0.71 mm, an outlet diameter of ∼0.10 mm and a length of ∼28 mm. The results show that the 1 and 3 MeV protons traverse through both samples without energy loss, while the tapered capillary showed better transmission than the straight capillary. (paper)

  15. Experimental results for characterization of a tapered plastic optical fiber sensor based on SPR

    Science.gov (United States)

    Cennamo, N.; Galatus, R.; Zeni, L.

    2015-05-01

    The experimental results obtained with two different Plastic Optical Fiber (POF) geometries, tapered and not-tapered, for a sensor based on Surface Plasmon Resonance (SPR) are presented. SPR is used for determining the refractive index variations at the interface between a gold layer and a dielectric medium (aqueous medium). In this work SPR sensors in POF configurations, useful for bio-sensing applications, have been realized for the optimization of the sensitivity and experimentally tested. The results show as the sensitivity increases with the tapered POF configuration, when the refractive index of aqueous medium increases.

  16. Optical microscope and tapered fiber coupling apparatus for a dilution refrigerator.

    Science.gov (United States)

    MacDonald, A J R; Popowich, G G; Hauer, B D; Kim, P H; Fredrick, A; Rojas, X; Doolin, P; Davis, J P

    2015-01-01

    We have developed a system for tapered fiber measurements of optomechanical resonators inside a dilution refrigerator, which is compatible with both on- and off-chip devices. Our apparatus features full three-dimensional control of the taper-resonator coupling conditions enabling critical coupling, with an overall fiber transmission efficiency of up to 70%. Notably, our design incorporates an optical microscope system consisting of a coherent bundle of 37,000 optical fibers for real-time imaging of the experiment at a resolution of ∼1 μm. We present cryogenic optical and optomechanical measurements of resonators coupled to tapered fibers at temperatures as low as 9 mK.

  17. Efficient formalism for treating tapered structures using the Fourier modal method

    DEFF Research Database (Denmark)

    Østerkryger, Andreas Dyhl; Gregersen, Niels

    2016-01-01

    We investigate the development of the mode occupations in tapered structures using the Fourier modal method. In order to use the Fourier modal method, tapered structures are divided into layers of uniform refractive index in the propagation direction and the optical modes are found within each...... layer. This is not very efficient and in this proceeding we take the first steps towards a more efficient formalism for treating tapered structures using the Fourier modal method. We show that the coupling coefficients through the structure are slowly varying and that only the first few modes...

  18. Suitability of Secondary PEEK Telescopic Crowns on Zirconia Primary Crowns: The Influence of Fabrication Method and Taper

    Directory of Open Access Journals (Sweden)

    Susanne Merk

    2016-11-01

    Full Text Available This study investigates the retention load (RL between ZrO2 primary crowns and secondary polyetheretherketone (PEEK crowns made by different fabrication methods with three different tapers. Standardized primary ZrO2 crowns were fabricated with three different tapers: 0°, 1°, and 2° (n = 10/group. Ten secondary crowns were fabricated (i milled from breCam BioHPP blanks (PM; (ii pressed from industrially fabricated PEEK pellets (PP (BioHPP Pellet; or (iii pressed from granular PEEK (PG (BioHPP Granulat. One calibrated operator adjusted all crowns. In total, the RL of 90 secondary crowns were measured in pull-off tests at 50 mm/min, and each specimen was tested 20 times. Two- and one-way ANOVAs followed by a Scheffé’s post-hoc test were used for data analysis (p < 0.05. Within crowns with a 0° taper, the PP group showed significantly higher retention load values compared with the other groups. Among the 1° taper, the PM group presented significantly lower retention loads than the PP group. However, the pressing type had no impact on the results. Within the 2° taper, the fabrication method had no influence on the RL. Within the PM group, the 2° taper showed significantly higher retention load compared with the 1° taper. The taper with 0° was in the same range value as the 1° and 2° tapers. No impact of the taper on the retention value was observed between the PP groups. Within the PG groups, the 0° taper presented significantly lower RL than the 1° taper, whereas the 2° taper showed no differences. The fabrication method of the secondary PEEK crowns and taper angles showed no consistent effect within all tested groups.

  19. Performance of nonsynchronous noncommensurate impedance transformers in comparison to tapered line transformers

    DEFF Research Database (Denmark)

    Kim, Kseniya; Zhurbenko, Vitaliy; Johansen, Tom Keinicke

    2012-01-01

    to a traditional tapered line impedance transformer. The increase in bandwidth of nonsynchronous noncommensurate impedance transformers typically leads to shortening the transformer length, which makes the transformer attractive for applications, where a wide operating band and high transformation ratios...

  20. Ultra-low-loss inverted taper coupler for silicon-on-insulator ridge waveguide

    DEFF Research Database (Denmark)

    Pu, Minhao; Liu, Liu; Ou, Haiyan

    2010-01-01

    An ultra-low-loss coupler for interfacing a silicon-on-insulator ridge waveguide and a single-mode fiber in both polarizations is presented. The inverted taper coupler, embedded in a polymer waveguide, is optimized for both the transverse-magnetic and transverse-electric modes through tapering...... the width of the silicon-on-insulator waveguide from 450 nm down to less than 15 nm applying a thermal oxidation process. Two inverted taper couplers are integrated with a 3-mm long silicon-on-insulator ridge waveguide in the fabricated sample. The measured coupling losses of the inverted taper coupler...... for transverse-magnetic and transverse-electric modes are ~0.36 dB and ~0.66 dB per connection, respectively....

  1. Propagation of atmospheric-pressure ionization waves along the tapered tube

    Science.gov (United States)

    Xia, Yang; Wang, Wenchun; Liu, Dongping; Yan, Wen; Bi, Zhenhua; Ji, Longfei; Niu, Jinhai; Zhao, Yao

    2018-02-01

    Gas discharge in a small radius dielectric tube may result in atmospheric pressure plasma jets with high energy and density of electrons. In this study, the atmospheric pressure ionization waves (IWs) were generated inside a tapered tube. The propagation behaviors of IWs inside the tube were studied by using a spatially and temporally resolved optical detection system. Our measurements show that both the intensity and velocity of the IWs decrease dramatically when they propagate to the tapered region. After the taper, the velocity, intensity, and electron density of the IWs are improved with the tube inner diameter decreasing from 4.0 to 0.5 mm. Our analysis indicates that the local gas conductivity and surface charges may play a role in the propagation of the IWs under such a geometrical constraint, and the difference in the dynamics of the IWs after the taper can be related to the restriction in the size of IWs.

  2. Fretting-corrosion at the modular tapers interface: Inspection of standard ASTM F1875-98.

    Science.gov (United States)

    Bingley, Rachel; Martin, Alan; Manfredi, Olivia; Nejadhamzeeigilani, Mahdiyar; Oladokun, Abimbola; Beadling, Andrew Robert; Siddiqui, Sohail; Anderson, James; Thompson, Jonathan; Neville, Anne; Bryant, Michael

    2018-05-01

    Interest in the degradation mechanisms at the modular tapers interfaces has been renewed due to increased reported cases of adverse reactions to metal debris and the appearance of wear and corrosion at the modular tapers interfaces at revision. Over the past two decades, a lot of research has been expended to understand the degradation mechanisms, with two primary implant loading procedures and orientations used consistently across the literature. ASTM F1875-98 is often used as a guide to understand and benchmark the tribocorrosion processes occurring within the modular tapers interface. This article presents a comparison of the two methods outlined in ASTM F1875-98 as well as a critique of the standard considering the current paradigm in pre-clinical assessment of modular tapers.

  3. Artificial Intelligence Procedures for Tree Taper Estimation within a Complex Vegetation Mosaic in Brazil.

    Directory of Open Access Journals (Sweden)

    Matheus Henrique Nunes

    Full Text Available Tree stem form in native tropical forests is very irregular, posing a challenge to establishing taper equations that can accurately predict the diameter at any height along the stem and subsequently merchantable volume. Artificial intelligence approaches can be useful techniques in minimizing estimation errors within complex variations of vegetation. We evaluated the performance of Random Forest® regression tree and Artificial Neural Network procedures in modelling stem taper. Diameters and volume outside bark were compared to a traditional taper-based equation across a tropical Brazilian savanna, a seasonal semi-deciduous forest and a rainforest. Neural network models were found to be more accurate than the traditional taper equation. Random forest showed trends in the residuals from the diameter prediction and provided the least precise and accurate estimations for all forest types. This study provides insights into the superiority of a neural network, which provided advantages regarding the handling of local effects.

  4. Design proposal for ultimate shear strength of tapered steel plate girders

    Directory of Open Access Journals (Sweden)

    A. Bedynek

    2017-03-01

    Full Text Available Numerous experimental and numerical studies on prismatic plate girders subjected to shear can be found in the literature. However, the real structures are frequently designed as non-uniform structural elements. The main objective of the research is the development of a new proposal for the calculation of the ultimate shear resistance of tapered steel plate girders taking into account the specific behaviour of such members. A new mechanical model is presented in the paper and it is used to show the differences between the behaviour of uniform and tapered web panels subjected to shear. EN 1993-1-5 design specifications for the determination of the shear strength for rectangular plates are improved in order to assess the shear strength of tapered elements. Numerical studies carried out on tapered steel plate girders subjected to shear lead to confirm the suitability of the mechanical model and the proposed design expression.

  5. Dynamic illumination of spatially restricted or large brain volumes via a single tapered optical fiber.

    Science.gov (United States)

    Pisanello, Ferruccio; Mandelbaum, Gil; Pisanello, Marco; Oldenburg, Ian A; Sileo, Leonardo; Markowitz, Jeffrey E; Peterson, Ralph E; Della Patria, Andrea; Haynes, Trevor M; Emara, Mohamed S; Spagnolo, Barbara; Datta, Sandeep Robert; De Vittorio, Massimo; Sabatini, Bernardo L

    2017-08-01

    Optogenetics promises precise spatiotemporal control of neural processes using light. However, the spatial extent of illumination within the brain is difficult to control and cannot be adjusted using standard fiber optics. We demonstrate that optical fibers with tapered tips can be used to illuminate either spatially restricted or large brain volumes. Remotely adjusting the light input angle to the fiber varies the light-emitting portion of the taper over several millimeters without movement of the implant. We use this mode to activate dorsal versus ventral striatum of individual mice and reveal different effects of each manipulation on motor behavior. Conversely, injecting light over the full numerical aperture of the fiber results in light emission from the entire taper surface, achieving broader and more efficient optogenetic activation of neurons, compared to standard flat-faced fiber stimulation. Thus, tapered fibers permit focal or broad illumination that can be precisely and dynamically matched to experimental needs.

  6. Tapered optical fibers as tools for probing magneto-optical trap characteristics

    International Nuclear Information System (INIS)

    Morrissey, Michael J.; Deasy, Kieran; Wu Yuqiang; Nic Chormaic, Sile; Chakrabarti, Shrabana

    2009-01-01

    We present a novel technique for measuring the characteristics of a magneto-optical trap (MOT) for cold atoms by monitoring the spontaneous emission from trapped atoms coupled into the guided mode of a tapered optical nanofiber. We show that the nanofiber is highly sensitive to very small numbers of atoms close to its surface. The size and shape of the MOT, determined by translating the cold atom cloud across the tapered fiber, is in excellent agreement with measurements obtained using the conventional method of fluorescence imaging using a charge coupled device camera. The coupling of atomic fluorescence into the tapered fiber also allows us to monitor the loading and lifetime of the trap. The results are compared to those achieved by focusing the MOT fluorescence onto a photodiode and it was seen that the tapered fiber gives slightly longer loading and lifetime measurements due to the sensitivity of the fiber, even when very few atoms are present.

  7. Fiber up-tapering and down-tapering for low-loss coupling between anti-resonant hollow-core fiber and solid-core fiber

    Science.gov (United States)

    Zhang, Naiqian; Wang, Zefeng; Xi, Xiaoming

    2017-10-01

    In this paper, we demonstrate a novel method for the low-loss coupling between solid-core multi-mode fibers (MMFs) and anti-resonant hollow-core fibers (AR-HCFs). The core/cladding diameter of the MMF is 50/125μm and the mode field diameter of the AR-HCFs are 33.3μm and 71.2μm of the ice-cream type AR-HCFs and the non-node type ARHCFs, respectively. In order to match the mode field diameters of these two specific AR-HCFs, the mode field diameter of the MMFs is increased or decreased by up-tapering or down-tapering the MMFs. Then, according to the principle of coupled fiber mode matching, the optimal diameter of tapered fiber for low-loss coupling is calculated. Based on beam propagation method, the calculated coupling losses without tapering process are 0.31dB and 0.89dB, respectively for a MMF-HCF-MMF structure of the ice-cream type AR-HCFs and the non-node type AR-HCFs. These values can be reduced to 0.096dB and 0.047dB when the outer diameters of the MMF are down-tapered to 116μm and up-tapered to 269μm, respectively. What's more, these results can also be verified by existing experiments.

  8. Comparison of the fracture resistance of dental implants with different abutment taper angles.

    Science.gov (United States)

    Wang, Kun; Geng, Jianping; Jones, David; Xu, Wei

    2016-06-01

    To investigate the effects of abutment taper angles on the fracture strength of dental implants with TIS (taper integrated screwed-in) connection. Thirty prototype cylindrical titanium alloy 5.0mm-diameter dental implants with different TIS-connection designs were divided into six groups and tested for their fracture strength, using a universal testing machine. These groups consisted of combinations of 3.5 and 4.0 mm abutment diameter, each with taper angles of 6°, 8° or 10°. 3-Dimensional finite element analysis (FEA) was also used to analyze stress states at implant-abutment connection areas. In general, the mechanical tests found an increasing trend of implant fracture forces as the taper angle enlarged. When the abutment diameter was 3.5 mm, the mean fracture forces for 8° and 10° taper groups were 1638.9 N ± 20.3 and 1577.1 N ± 103.2, respectively, both larger than that for the 6° taper group of 1475.0 N ± 24.4, with the largest increasing rate of 11.1%. Furthermore, the difference between 8° and 6° taper groups was significant, based on Tamhane's multiple comparison test (Pabutment groups, as the taper angle was enlarged from 6° to 8° and 10°, the mean fracture value was increased from 1066.7 N ± 56.1 to 1241.4 N ± 6.4 and 1419.3 N ± 20.0, with the largest increasing rate of 33.1%, and the differences among the three groups were significant (Pabutment taper angles and supported the findings of the static tests. In conclusion, increases of the abutment taper angle could significantly increase implant fracture resistance in most cases established in the study, which is due to the increased implant wall thickness in the connection part resulting from the taper angle enlargement. The increasing effects were notable when a thin implant wall was present to accommodate wide abutments. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. The Morse taper junction in modular revision hip replacement--a biomechanical and retrieval analysis.

    Science.gov (United States)

    Schramm, M; Wirtz, D C; Holzwarth, U; Pitto, R P

    2000-04-01

    All biomaterials used for total joint surgery are subjected to wear mechanisms. Morse taper junctions of modular hip revision implants are predilection sites for both fretting and crevice corrosion, dissociation and breakage of the components. The aim of this study is to quantify wear and study metallurgical changes of Morse taper junctions of in-vitro and in-vivo loaded modular revision stems. Three modular revision stems (MRP-Titan, Peter Brehm GmbH, Germany) were loaded by a servohydraulic testing machine. The loads and conditions used exceeded by far the values required by ISO-standard 7206. The tests were performed with maximum axial loads of 3,500 N to 4,000 N over 10-12 x 10(6) cycles at 2 Hz. Additionally, the female part of the taper junctions were coated with blood and bone debris. The free length of the implant was set to 200 mm. One other MRP stem was investigated after retrieval following 5.5 years of in-vivo use. All contact surfaces of the modular elements were assessed by visual inspection, optical microscopy and scanning electron microscopy (SEM). The degree of plastic deformation of the male part of the morse taper junction was determined by contouroscopy. None of the morse taper junctions broke or failed mechanically. Corrosion and wear affected all tapers, especially at the medial side. The retrieved implant showed no cracks and the amount of debris measured only one third of that for the stems tested in-vitro. The present retrieval and laboratory investigations have proven, that the morse taper junctions of the MRP-titanium stem are stable and resistant to relevant wear mechanisms. The longevity of the junctions for clinical use is given. If an optimal taper design is selected, the advantages of modular femoral components in total hip revision arthroplasty will outweigh the possible risks.

  10. Empirical optimization of undulator tapering at FLASH2 and comparison with numerical simulations

    Energy Technology Data Exchange (ETDEWEB)

    Mak, Alan; Curbis, Francesca; Werin, Sverker [Lund Univ. (Sweden). MAX IV Laboratory; Faatz, Bart [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2016-08-15

    In a free-electron laser equipped with variable-gap undulator modules, the technique of undulator tapering opens up the possibility to increase the radiation power beyond the initial saturation point, thus enhancing the efficiency of the laser. The effectiveness of the enhancement relies on the proper optimization of the taper profile. In this work, a multidimensional optimization approach is implemented empirically in the X-ray free-electron laser FLASH2. The empirical results are compared with numerical simulations.

  11. Design and Synthesis of Network-Forming Triblock Copolymers Using Tapered Block Interfaces

    OpenAIRE

    Kuan, Wei-Fan; Roy, Raghunath; Rong, Lixia; Hsiao, Benjamin S.; Epps, Thomas H.

    2012-01-01

    We report a strategy for generating novel dual-tapered poly(isoprene-b-isoprene/styrene-b-styrene-b-styrene/methyl methacrylate-b-methyl methacrylate) [P(I-IS-S-SM-M)] triblock copolymers that combines anionic polymerization, atom transfer radical polymerization (ATRP), and Huisgen 1,3-dipolar cycloaddition click chemistry. The tapered interfaces between blocks were synthesized via a semi-batch feed using programmable syringe pumps. This strategy allows us to manipulate the transition region ...

  12. Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis.

    Science.gov (United States)

    Atieh, Momen A; Alsabeeha, Nabeel; Duncan, Warwick J

    2018-05-15

    Clinical trials have suggested that dental implants with a tapered configuration have improved stability at placement, allowing immediate placement and/or loading. The aim of this systematic review and meta-analysis was to evaluate the implant stability of tapered dental implants compared to standard parallel-walled dental implants. Applying the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement, randomized controlled trials (RCTs) were searched for in electronic databases and complemented by hand searching. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool and data were analyzed using statistical software. A total of 1199 studies were identified, of which, five trials were included with 336 dental implants in 303 participants. Overall meta-analysis showed that tapered dental implants had higher implant stability values than parallel-walled dental implants at insertion and 8 weeks but the difference was not statistically significant. Tapered dental implants had significantly less marginal bone loss compared to parallel-walled dental implants. No significant differences in implant failure rate were found between tapered and parallel-walled dental implants. There is limited evidence to demonstrate the effectiveness of tapered dental implants in achieving greater implant stability compared to parallel-walled dental implants. Superior short-term results in maintaining peri-implant marginal bone with tapered dental implants are possible. Further properly designed RCTs are required to endorse the supposed advantages of tapered dental implants in immediate loading protocol and other complex clinical scenarios. © 2018 Wiley Periodicals, Inc.

  13. Modulation-instability biosensing using an As2S3 chalcogenide tapered fiber

    DEFF Research Database (Denmark)

    Markos, Christos; Bang, Ole

    2016-01-01

    We demonstrate an experimentally feasible biosensor design based on As2S3 chalcogenide tapered fiber. Pumping the fiber close to 1064 nm, a record sensitivity up to ~18 nm/nm was predicted.......We demonstrate an experimentally feasible biosensor design based on As2S3 chalcogenide tapered fiber. Pumping the fiber close to 1064 nm, a record sensitivity up to ~18 nm/nm was predicted....

  14. Individual taper models for natural cedar and Taurus fir mixed stands of Bucak Region, Turkey

    Directory of Open Access Journals (Sweden)

    Ramazan Özçelik

    2017-11-01

    Full Text Available In this study, we assessed the performance of different types of taper equations for predicting tree diameters at specific heights and total stem volumes for mixed stands of Taurus cedar (Cedrus libani A. Rich. and Taurus fir (Abies cilicica Carr.. We used data from mixed stands containing a total of 131 cedar and 124 Taurus fir trees. We evaluated six commonly used and well-known forestry taper functions developed by a variety of researchers (Biging (1984, Zakrzewski (1999, Muhairwe (1999, Fang et al. (2000, Kozak (2004, and Sharma and Zhang (2004. To address problems related to autocorrelation and multicollinearity in the hierarchical data associated with the construction of taper models, we used appropriate statistical procedures for the model fitting. We compared model performances based on the analysis of three goodness-of-fit statistics and found the compatible segmented model of Fang et al. (2000 to be superior in describing the stem profile and stem volume of both tree species in mixed stands. The equation used by Zakrzewski (1999 exhibited the poorest fitting results of the three taper equations. In general, we found segmented taper equations to provide more accurate predictions than variable-form models for both tree species. Results from the non-linear extra sum of squares method indicate that stem tapers differ among tree species in mixed stands. Therefore, a different taper function should be used for each tree species in mixed stands in the Bucak district. Using individual-specific taper equations yields more robust estimations and, therefore, will enhance the prediction accuracy of diameters at different heights and volumes in mixed stands.

  15. Three-Dimensional Optical Trapping for Cell Isolation Using Tapered Fiber Probe by Dynamic Chemical Etching

    International Nuclear Information System (INIS)

    Taguchi, K; Okada, J; Nomura, Y; Tamura, K

    2012-01-01

    In this paper, chemically etched fiber probe was proposed for laser trapping and manipulation of cells. We fabricated tapered fiber probe by dynamic chemical etching technique. Three-Dimensional optical trap of a yeast cell dispersed in water solution could be formed by the fiber tip with 17deg tip. Optical forces were sufficient to move the yeast cell for trapping and manipulation. From these experimental results, it was found that our proposed tapered fiber tip was a promising tool for cell isolation.

  16. Oseointegración en implantes Bicon® cargados a los tres meses después de haber sido colocados mediante la técnica de elevación interna del seno maxilar en pacientes atendidos en la facultad de odontología de la universidad de Cartagena

    Directory of Open Access Journals (Sweden)

    Lorena Meñaca

    2013-10-01

    Full Text Available ResumenObjetivo: El objetivo general de este estudio fue evaluar la oseointegración en implantes tipo Bicon® cargados a los tres meses de colocados, mediante la técnica de elevación interna de seno maxilar. Materiales y Métodos: Este estudio se establece como una investigación de tipo descriptivo, basado en una serie de casos clínicos tratados. En la recolección de la información se utilizó un instrumento en donde se registraron los datos personales de los pacientes, se realizó la toma de radiografías panorámicas iniciales y radiografías periapicales utilizadas para observar la neoformación ósea y medir el aumento del piso del seno maxilar. La información fue consignada y tabulada en tablas y gráficos de frecuencia. Resultados: De los implantes colocados ninguno presentó movilidad ni patologías perimplantares, el piso del seno maxilar se aumentó en promedio 2.6 mm y se presentó neoformación ósea adecuada a los tres meses, lo que permitió la carga de los implantes. Conclusiones: Se determinó que a los tres meses se logra una suficiente oseointegración con los implantes, que en conjunto con la elevación interna del piso del seno maxilar y el grado de neoformación ósea alcanzado dieron a los implantes las condiciones necesarias para poder cargar los mismos. Además, la ausencia total de lesiones perimplantarias señalan el cumplimiento estricto de las normas tecnoquirurgicas, evaluación e instrucción a los pacientes que se han estado manejando dentro del proceso de la colocación de los implantes Bicon®. (Duazary 2007; 2: 93 - 99AbstractObjective: The general objective of this investigation was to evaluate the oseointegration of Bicon® dental implants that have been charge after three month of put it with internal sinus lift in maxillary sinus Material and Methods: This investigation has been stablished as a descriptive study, support in clinic cases. In order to recollect the information, a format was used to

  17. [Evaluation of preparation of curved root canals using hand-used ProTaper].

    Science.gov (United States)

    Nie, Min; Zhao, Xin-Chen; Peng, Bin; Fan, Ming-Wen; Bian, Zhuan

    2009-05-01

    To evaluate the shaping ability of hand-used ProTaper on curved canals using Endodontic Cube. Fifty-four curved root canals in vitro were selected and divided into three groups according to the curved degree (alpha), group A: 0 degrees hand-used ProTaper. Before and after shaping, photograph of all the sections were taken under a stereomicroscope. Statistical analyses were performed. The dentin cutting quantity of the whole canal prepared with ProTaper in group B and C was larger than that of group A. The deviation distance of the whole canal prepared by ProTaper in group C was significantly larger than that in group A, and the deviation distance in middle portion larger than that in group B. The maintaining ability in the middle portion of group C by ProTaper was worse than that of group A and B. The curvature of root canal may increase the cutting quantity of the -dentin and reduce the ability of remaining original canal shape prepared by ProTaper.

  18. Effects of self-adjusting file, Mtwo, and ProTaper on the root canal wall.

    Science.gov (United States)

    Hin, Ellemieke S; Wu, Min-Kai; Wesselink, Paul R; Shemesh, Hagay

    2013-02-01

    The purpose of this ex vivo study was to observe the incidence of cracks in root dentin after root canal preparation with hand files, self-adjusting file (SAF), ProTaper, and Mtwo. One hundred extracted mandibular premolars with single canals were randomly selected. Two angulated radiographs were taken for each tooth, and the width of the canal was measured at 9 mm from the apex. Five groups of 20 teeth each were comparable in canal width. The control group was left unprepared. Four experimental groups were instrumented with hand files, ProTaper, Mtwo, and SAF. Roots were then sectioned horizontally and observed under a microscope. The presence of dentinal cracks and their location were noted. The difference between the experimental groups was analyzed with a χ(2) test. No cracks were observed in the control group. In the experimental groups, ProTaper, Mtwo, and SAF caused cracks in 35%, 25%, and 10% of teeth, respectively. The hand-file group did not show any dentinal cracks (P ProTaper and Mtwo caused more cracks than hand files (P .05). Instrumentation of root canals with SAF, Mtwo, and ProTaper could cause damage to root canal dentin. SAF has a tendency to cause less dentinal cracks as compared with ProTaper or Mtwo. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Effects of intensified training and taper on immune function

    Directory of Open Access Journals (Sweden)

    Elena Papacosta

    2013-03-01

    Full Text Available Although resting immune function is not very different in athletes compared with non-athletes periods of intensified training (overreaching in already well trained athletes can result in a depression of immunity in the resting state. Illness-prone athletes appear to have an altered cytokine response to antigen stimulation and exercise. Having low levels of salivary IgA secretion also makes athletes more susceptible to upper respiratory tract infections. Overtraining is associated with recurrent infections and immunodepression is common, but immune functions do not seem to be reliable markers of impending overtraining. There are several possible causes of the diminution of immune function associated with periods of heavy training. One mechanism may simply be the cumulative effects of repeated bouts of intense exercise (with or without tissue damage with the consequent elevation of stress hormones, particularly glucocorticoids such as cortisol, causing temporary inhibition of TH-1 cytokines with a relative dampening of the cell-mediated response. When exercise is repeated frequently there may not be sufficient time for the immune system to recover fully. Tapering has been described as a gradual reduction in the training load which allows the recovery of physiological capacities that were impaired by previous intensive training and permits further training-induced adaptations to occur accompanied by competition performance enhancements. The majority of the studies that have examined the recovery of immunoendocrine responses during 1-3 week tapers in trained athletes have mainly reported enhanced performance, often accompanied by increased anabolic activity, reduced physiological stress and restoration of mucosal immunity and immune function.Quando se compara a função imune, em repouso, de atletas e não atletas, não se verificam grandes diferenças. Porém, períodos de treinamento intensificado ("overreaching" em atletas bem treinados podem

  20. Radiological evaluation of the morphological changes of root canals shaped with ProTaper for hand use and the ProTaper and RaCe rotary instruments.

    Science.gov (United States)

    Aguiar, Carlos M; Câmara, Andréa C

    2008-12-01

    This study evaluated, by means of the radiography examination, the occurrence of deviations in the apical third of root canals shaped with hand and rotary instruments. Sixty mandibular human molars were divided into three groups. The root canals in group 1 were instrumented with ProTaper (Dentsply/Maillefer, Ballaigues, Switzerland) for hand use, group 2 with ProTaper and group 3 with RaCe. The images obtained by double superimposition of the pre- and postoperative radiographs were evaluated by two endodontists with the aid of a magnifier-viewer and a fivefold magnifier. Statistical analysis was performed using the Fisher-Freeman-Halton. The instrumentation using the ProTaper for hand use showed 25% of the canals with a deviation in the apical third, as did the ProTaper, while the corresponding figure for the RaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland) was 20%, but these results were not statistically significant. There was no correlation between the occurrence of deviations in the apical third and the systems used.

  1. Analysis of elastic stiffness for the leaf type holddown spring assembly with uniformly tapered thickness considering the point of taper runout

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ki Nam [Korea Atomic Energy Research Institute, Daeduk (Korea, Republic of)

    1996-04-01

    In the case that the point of taper runout is outside the bent region of spring base, a formula to evaluate the elastic stiffness of the leaf type holddown spring (HDS) assembly with uniformly tapered thickness from t{sub 0} to t{sub 1} (t{sub 0}>t{sub 1}) has been analytically derived by applying the engineering beam theory and Casiliano`s theorem based on strain energy. It has found that taper runouts for the 14x14 and 17x17 type KOFA HDS were up to 2.2 mm and effects on their elastic stiffnesses were about 3.70%, and that the elastic stiffness of the HDS was mainly caused by bending moment. And in addition, for the HDS designed/manufactured from Westinghouse, elastic stiffnesses from the derived formula were in good agreement with those from the Westinghouse`s empirical formula. Therefore, the derived formula could be applicable to evaluating the elastic stiffness of any HDS with tapered thickness only with the informations of the geometric data and material properties of leaf springs regardness of the manufacturing companies. 11 tabs., 4 figs., 25 refs. (Author) .new.

  2. Suitability of Secondary PEEK Telescopic Crowns on Zirconia Primary Crowns: The Influence of Fabrication Method and Taper.

    Science.gov (United States)

    Merk, Susanne; Wagner, Christina; Stock, Veronika; Eichberger, Marlis; Schmidlin, Patrick R; Roos, Malgorzata; Stawarczyk, Bogna

    2016-11-08

    This study investigates the retention load (RL) between ZrO₂ primary crowns and secondary polyetheretherketone (PEEK) crowns made by different fabrication methods with three different tapers. Standardized primary ZrO₂ crowns were fabricated with three different tapers: 0°, 1°, and 2° ( n = 10/group). Ten secondary crowns were fabricated (i) milled from breCam BioHPP blanks (PM); (ii) pressed from industrially fabricated PEEK pellets (PP) (BioHPP Pellet); or (iii) pressed from granular PEEK (PG) (BioHPP Granulat). One calibrated operator adjusted all crowns. In total, the RL of 90 secondary crowns were measured in pull-off tests at 50 mm/min, and each specimen was tested 20 times. Two- and one-way ANOVAs followed by a Scheffé's post-hoc test were used for data analysis ( p impact on the results. Within the 2° taper, the fabrication method had no influence on the RL. Within the PM group, the 2° taper showed significantly higher retention load compared with the 1° taper. The taper with 0° was in the same range value as the 1° and 2° tapers. No impact of the taper on the retention value was observed between the PP groups. Within the PG groups, the 0° taper presented significantly lower RL than the 1° taper, whereas the 2° taper showed no differences. The fabrication method of the secondary PEEK crowns and taper angles showed no consistent effect within all tested groups.

  3. Development and evaluation of teak (Tectona grandis L.f. taper equations in northern Thailand

    Directory of Open Access Journals (Sweden)

    Andrew J. Warner

    2016-09-01

    Full Text Available Taper refers to the general decrease in the regular outline of a solid body from its base to its tip. Taper models are used to estimate the volume and value of wood products from harvesting trees. Teak (Tectona grandis L.f. is highly valued as one of the world's most preferred timbers and a teak taper equation is required to inform optimal harvesting strategies given the limited plantation resource available in Thailand. Teak taper equations were developed and evaluated based on 331 sample trees collected in 2014 from eight plantations in northern Thailand aged from 10 to 46 yr using two taper model formulations—the Kozak variable-exponent taper model and the Goodwin cubic polynomial model comprising hyperbolic and parabolic terms. Variants based on both model types were fitted using nonlinear regression analysis with diameter at breast height, total tree height and height of girth measurement as the independent variables to estimate diameter underbark at the nominated height. Goodness-of-fit and leave-one-out cross validation with lack-of-fit statistical testing combined with extensive graphical analysis of residuals were used to select the best model. A Goodwin model variant (named FIO-teak1 as the first plantation teak taper model known to be published in Thailand provided the best estimates of volume and diameter underbark. A simple case study confirmed that FIO-teak1 in combination with the Farm Forestry Toolbox software package could assist teak plantation managers in decision making associated with optimizing log grade value based on standing tree inventory data.

  4. The study of 670.7 nm red light generated by intracavity frequency doubling of a Q-switched Nd : YAlO3 laser

    International Nuclear Information System (INIS)

    Zhu Haiyong; Zhang Ge; Huang Chenghui; Wei Yong; Huang Lingxiong; Huang Yidong

    2009-01-01

    High-power 670.7 nm red light was obtained by intracavity frequency doubling of a Q-switched Nd : YAlO 3 (Nd : YAP) laser with a critical phase matching (θ = 85.9 0 , φ = 0 0 ) cut LBO. Experimental configurations using V-cavity and Z-cavity have been adopted for comparison. The highest output power of 19.7 W was achieved in the Z-cavity with optical-optical efficiency of 4%. Compared with the laser using an Nd : YAG crystal, the adoption of Nd : YAP simplified the laser system in the absence of a solid etalon and the Brewster plate. The output power stability of the red laser was investigated and the fluctuation was lower than 3% at the output power of 18 W an hour.

  5. Diode-side-pumped intracavity frequency-doubled Nd:YAG/BaWO4 Raman laser generating average output power of 3.14 W at 590 nm.

    Science.gov (United States)

    Li, Shutao; Zhang, Xingyu; Wang, Qingpu; Zhang, Xiaolei; Cong, Zhenhua; Zhang, Huaijin; Wang, Jiyang

    2007-10-15

    We report a linear-cavity high-power all-solid-state Q-switched yellow laser. The laser source comprises a diode-side-pumped Nd:YAG module that produces 1064 nm fundamental radiation, an intracavity BaWO(4) Raman crystal that generates a first-Stokes laser at 1180 nm, and a KTP crystal that frequency doubles the first-Stokes laser to 590 nm. A convex-plane cavity is employed in this configuration to counteract some of the thermal effect caused by high pump power. An average output power of 3.14 W at 590 nm is obtained at a pulse repetition frequency of 10 kHz.

  6. Towards a versatile active wavelength converter for all-optical networks based on quasi-phase matched intra-cavity difference-frequency generation.

    Science.gov (United States)

    Torregrosa, Adrián J; Maestre, Haroldo; Capmany, Juan

    2013-11-18

    The availability of reconfigurable all-optical wavelength converters for an efficient and flexible use of optical resources in WDM (wavelength division multiplexing) networks is still lacking at present. We propose and report preliminary results on a versatile active technique for multiple and tunable wavelength conversions in the 1500-1700 nm spectral region. The technique is based on combining broadband quasi-phase matched intra-cavity parametric single-pass difference-frequency generation close to degeneracy in a diode-pumped tunable laser. A periodically poled stoichiometric lithium tantalate crystal is used as the nonlinear medium, with a parametric pump wave generated in a continuous-wave self-injection locked Cr3+:LiCAF tunable laser operating at around 800 nm.

  7. 303 nm continuous wave ultraviolet laser generated by intracavity frequency-doubling of diode-pumped Pr3+:LiYF4 laser

    Science.gov (United States)

    Zhu, Pengfei; Zhang, Chaomin; Zhu, Kun; Ping, Yunxia; Song, Pei; Sun, Xiaohui; Wang, Fuxin; Yao, Yi

    2018-03-01

    We demonstrate an efficient and compact ultraviolet laser at 303 nm generated by intracavity frequency doubling of a continuous wave (CW) laser diode-pumped Pr3+:YLiF4 laser at 607 nm. A cesium lithium borate (CLBO) crystal, cut for critical type I phase matching at room temperature, is used for second-harmonic generation (SHG) of the fundamental laser. By using an InGaN laser diode array emitting at 444.3 nm with a maximum incident power of 10 W, as high as 68 mW of CW output power at 303 nm is achieved. The output power stability in 4 h is better than 2.85%. To the best of our knowledge, this is high efficient UV laser generated by frequency doubling of an InGaN laser diode array pumped Pr3+:YLiF4 laser.

  8. Comparison of Small-Scale Actively and Passively Q-Switched Eye-Safe Intracavity Optical Parametric Oscillators at 1.57 μm

    International Nuclear Information System (INIS)

    Miao Jie-Guang; Pan Yu-Zhai; Qu Shi-Liang

    2012-01-01

    The first experimental comparison between the actively and passively Q-switched intracavity optical parametric oscillators (IOPOs) at 1.57 μm driven by a small-scale diode-pumped Nd:YVO 4 laser are thoroughly presented. It is found that the performances of the two types of IOPOs are complementary. The actively Q-switched IOPO features a shorter pulse duration, a higher peak power, and a superior power and pulse stability. However, in terms of compactness, operation threshold and conversion efficiency, passively Q-switched IOPOs are more attractive. It is further indicated that the passively Q-switched IOPO at 1.57μm is a promising and cost-effective eye-safe laser source, especially at the low and moderate output levels. In addition, instructional improvement measures for the two types of IOPOs are also summarized. (fundamental areas of phenomenology(including applications))

  9. Studying energy absorption in tapered thick walled tubes

    Directory of Open Access Journals (Sweden)

    P. Hosseini Tehrani

    Full Text Available In many engineering structures different energy absorption systems may be used to improve crashworthiness capability of the system and to control damages that may occur in a system during an accident. Therefore, extensive research has been done on the energy-absorbing cells. In this paper, energy absorption in tapered thick walled tubes has been investigated. As a practical case, studies have been focused on the crush element of Siemens ER24PC locomotive. To investigate performance of this part at collision time, it has been modeled in Abaqus software and its collision characteristics have been evaluated. Considering that the crash element is folded at time of collision, an analytical approach has been presented for calculation of instantaneous folding force under axial load. Basis of this method is definition and analysis of main folding mechanism and calculation of average folding force. This method has been used for validation of the results of numerical solution. Since sheet thickness of the crash element is high and may be ruptured at time of collision, some damage models have been used for numerical simulations. One of the three damage models used in this paper is available in the software and coding has been done for two other damage models and desirable damage model has been specified by comparing results of numerical solution with results of laboratory test. In addition, authenticity of the desirable damage model has been studied through ECE R 66 standard. To improve crashworthiness characteristic some attempts, such as use of metal foam and creation of trigger in suitable situations to reduce maximum force resulting from collision, have been performed. Finally though different simulation optimal crush element has been introduced and its performance and efficiency have been evaluated.

  10. The Effect of Vibration Characteristics on the Atomization Rate in a Micro-Tapered Aperture Atomizer

    Directory of Open Access Journals (Sweden)

    Qiufeng Yan

    2018-03-01

    Full Text Available Because little is known about the atomization theory of a micro-tapered aperture atomizer, we investigated the vibration characteristics of this type of atomizer. The atomization mechanism of a micro-tapered aperture atomizer was described, and the atomization rate equation was deduced. As observed via microscopy, the angle of the micro-tapered aperture changes with the applied voltage, which proved the existence of a dynamic cone angle. The forward and reverse atomization rates were measured at various voltages, and the influence of the micro-tapered aperture and its variation on the atomization rate was characterized. The resonance frequency of the piezoelectric vibrator was obtained using a laser vibrometer, and the atomization rates were measured at each resonance frequency. From experiments, we found that the atomization rates at the first five resonance frequencies increased as the working frequency increased. At the fifth resonance frequency (121.1 kHz, the atomization rate was maximized (0.561 mL/min, and at the sixth resonance frequency (148.3 kHz, the atomization rate decreased significantly (0.198 mL/min. The experimental results show that the vibration characteristics of the piezoelectric vibrator have a relatively strong impact on the atomization rate. This research is expected to contribute to the manufacture of micro-tapered aperture atomizers.

  11. Flexural-torsional vibration of a tapered C-section beam

    Science.gov (United States)

    Dennis, Scott T.; Jones, Keith W.

    2017-04-01

    Previous studies have shown that numerical models of tapered thin-walled C-section beams based on a stepped or piecewise prismatic beam approximation are inaccurate regardless of the number of elements assumed in the discretization. Andrade recently addressed this problem by extending Vlasov beam theory to a tapered geometry resulting in new terms that vanish for the uniform beam. (See One-Dimensional Models for the Spatial Behaviour of Tapered Thin-Walled Bars with Open Cross-Sections: Static, Dynamic and Buckling Analyses, PhD Thesis, University of Coimbra, Portugal, 2012, https://estudogeral.sib.uc.pt) In this paper, we model the coupled bending-twisting vibration of a cantilevered tapered thin-walled C-section using a Galerkin approximation of Andrade's beam equations resulting in an 8-degree-of-freedom beam element. Experimental natural frequencies and mode shapes for 3 prismatic and 2 tapered channel beams are compared to model predictions. In addition, comparisons are made to detailed shell finite element models and exact solutions for the uniform beams to confirm the validity of the approach. Comparisons to the incorrect stepped model are also presented.

  12. Thermoelectric generator performance analysis: Influence of pin tapering on the first and second law efficiencies

    International Nuclear Information System (INIS)

    Yilbas, B.S.; Ali, H.

    2015-01-01

    Highlights: • Double tapering of thermoelectric elements improves first and second law efficiency. • Pin geometric feature maximizing device output work does not maximize thermal efficiency. • Pin geometric feature maximizing first law efficiency slight alters for maximum second law efficiency. • External resistance and operating temperature ratios influence design configuration of thermoelectric generator. - Abstract: Thermoelectric generators are the important candidates for clean energy conversion from the waste heat; however, their low efficiency limits the practical applications of the devices. Tailoring the geometric configuration of the device in line with the operating conditions can improve the device performance. Consequently; in the present study, the influence of the pin geometric configuration on the thermoelectric generator performance is investigated. The dimensionless tapering parameter is introduced and its effect on the first and second law efficiencies is examined for various operating conditions including the external load resistance and the temperature ratio. It is found that the first and second law efficiencies are significantly influenced by the pin geometry. The dimensionless tapering parameter (a), increasing tapering of the thermoelectric pins, within the range of 2 ⩽ a ⩽ 4 results in improved first and second law efficiencies. However, the dimensionless tapering parameter maximizing the first and second law efficiencies does not maximize the device output power. This behavior is associated with the external load resistance which has a considerable influence on the device output power such that increasing external load resistance lowers the device output power

  13. Membrane voltage changes in passive dendritic trees: a tapering equivalent cylinder model.

    Science.gov (United States)

    Poznański, R R

    1988-01-01

    An exponentially tapering equivalent cylinder model is employed in order to approximate the loss of the dendritic trunk parameter observed from anatomical data on apical and basilar dendrites of CA1 and CA3 hippocampal pyramidal neurons. This model allows dendritic trees with a relative paucity of branching to be treated. In particular, terminal branches are not required to end at the same electrotonic distance. The Laplace transform method is used to obtain analytic expressions for the Green's function corresponding to an instantaneous pulse of current injected at a single point along a tapering equivalent cylinder with sealed ends. The time course of the voltage in response to an arbitrary input is computed using the Green's function in a convolution integral. Examples of current input considered are (1) an infinitesimally brief (Dirac delta function) pulse and (2) a step pulse. It is demonstrated that inputs located on a tapering equivalent cylinder are more effective at the soma than identically placed inputs on a nontapering equivalent cylinder. Asymptotic solutions are derived to enable the voltage response behaviour over both relatively short and long time periods to be analysed. Semilogarithmic plots of these solutions provide a basis for estimating the membrane time constant tau m from experimental transients. Transient voltage decrement from a clamped soma reveals that tapering tends to reduce the error associated with inadequate voltage clamping of the dendritic membrane. A formula is derived which shows that tapering tends to increase the estimate of the electrotonic length parameter L.

  14. Tapered optical fiber tip probes based on focused ion beam-milled Fabry-Perot microcavities

    Science.gov (United States)

    André, Ricardo M.; Warren-Smith, Stephen C.; Becker, Martin; Dellith, Jan; Rothhardt, Manfred; Zibaii, M. I.; Latifi, H.; Marques, Manuel B.; Bartelt, Hartmut; Frazão, Orlando

    2016-09-01

    Focused ion beam technology is combined with dynamic chemical etching to create microcavities in tapered optical fiber tips, resulting in fiber probes for temperature and refractive index sensing. Dynamic chemical etching uses hydrofluoric acid and a syringe pump to etch standard optical fibers into cone structures called tapered fiber tips where the length, shape, and cone angle can be precisely controlled. On these tips, focused ion beam is used to mill several different types of Fabry-Perot microcavities. Two main cavity types are initially compared and then combined to form a third, complex cavity structure. In the first case, a gap is milled on the tapered fiber tip which allows the external medium to penetrate the light guiding region and thus presents sensitivity to external refractive index changes. In the second, two slots that function as mirrors are milled on the tip creating a silica cavity that is only sensitive to temperature changes. Finally, both cavities are combined on a single tapered fiber tip, resulting in a multi-cavity structure capable of discriminating between temperature and refractive index variations. This dual characterization is performed with the aid of a fast Fourier transform method to separate the contributions of each cavity and thus of temperature and refractive index. Ultimately, a tapered optical fiber tip probe with sub-standard dimensions containing a multi-cavity structure is projected, fabricated, characterized and applied as a sensing element for simultaneous temperature and refractive index discrimination.

  15. The Effect of Vibration Characteristics on the Atomization Rate in a Micro-Tapered Aperture Atomizer.

    Science.gov (United States)

    Yan, Qiufeng; Zhang, Jianhui; Huang, Jun; Wang, Ying

    2018-03-21

    Because little is known about the atomization theory of a micro-tapered aperture atomizer, we investigated the vibration characteristics of this type of atomizer. The atomization mechanism of a micro-tapered aperture atomizer was described, and the atomization rate equation was deduced. As observed via microscopy, the angle of the micro-tapered aperture changes with the applied voltage, which proved the existence of a dynamic cone angle. The forward and reverse atomization rates were measured at various voltages, and the influence of the micro-tapered aperture and its variation on the atomization rate was characterized. The resonance frequency of the piezoelectric vibrator was obtained using a laser vibrometer, and the atomization rates were measured at each resonance frequency. From experiments, we found that the atomization rates at the first five resonance frequencies increased as the working frequency increased. At the fifth resonance frequency (121.1 kHz), the atomization rate was maximized (0.561 mL/min), and at the sixth resonance frequency (148.3 kHz), the atomization rate decreased significantly (0.198 mL/min). The experimental results show that the vibration characteristics of the piezoelectric vibrator have a relatively strong impact on the atomization rate. This research is expected to contribute to the manufacture of micro-tapered aperture atomizers.

  16. A numerical study of Taylor vortex flow in a finite length tapered annulus

    International Nuclear Information System (INIS)

    Noui-Mehidi, M N; Ohmura, N; Wu, J

    2005-01-01

    The transient evolution and steady state analysis of Taylor vortex flow in a tapered annulus was conducted by numerical experiments in the case where the inner cylinder was rotated and the outer one fixed. The gap between the cylinders was linearly tapered from a supercritical value at the upper base to the critical value at the lower base. The wavelength adjustment depended on the variation of Reynolds number in the spatially ramped gap. The axisymmetric conservative governing equations were solved by the use of an simplified marker and cell (SMAC) algorithm. A coordinate transformation function allowed us to numerically solve the problem in a rectangular computational domain. The results have shown that Taylor vortices growth was sensitive to the spatial ramp of the gap even with tapering angle values less than one degree. The interaction between the inflow and outflow boundaries could be clearly seen as the taper angle was increased. The investigation of the transient dynamics related to the flow system also revealed a characteristic dependence on the taper angle

  17. Increasing the Strength of Adhesively Bonded Joints by Tapering the Adherends

    International Nuclear Information System (INIS)

    GUESS, TOMMY R.; METZINGER, KURT E.

    1999-01-01

    Wind turbine blades are often fabricated with composite materials. These composite blades are frequently attached to a metallic structure with an adhesive bond. For the baseline composite-to-steel joint considered in this study, failure typically occurs when the adhesive debonds from the steel adherend. Previous efforts established that the adhesive peel stresses strongly influence the strength of these joints for both single-cycle and fatigue loading. This study focused on reducing the adhesive peel stresses present in these joints by tapering the steel adherends. Several different tapers were evaluated using finite element analysis before arriving at a final design. To confirm that the selected taper was an improvement to the existing design, the baseline joint and the modified joint were tested in both compression and tension. In these axial tests, the compressive strengths of the joints with tapered adherends were greater than those of the baseline joints for both single-cycle and low-cycle fatigue. In addition, only a minor reduction in tensile strength was observed for the joints with tapered adherends when compared to the baseline joints. Thus, the modification would be expected to enhance the overall performance of this joint

  18. Effect of sequence dispersity on morphology of tapered diblock copolymers from molecular dynamics simulations.

    Science.gov (United States)

    Levine, William G; Seo, Youngmi; Brown, Jonathan R; Hall, Lisa M

    2016-12-21

    Tapered diblock copolymers are similar to typical AB diblock copolymers but have an added transition region between the two blocks which changes gradually in composition from pure A to pure B. This tapered region can be varied from 0% (true diblock) to 100% (gradient copolymer) of the polymer length, and this allows some control over the microphase separated domain spacing and other material properties. We perform molecular dynamics simulations of linearly tapered block copolymers with tapers of various lengths, initialized from fluids density functional theory predictions. To investigate the effect of sequence dispersity, we compare systems composed of identical polymers, whose taper has a fixed sequence that most closely approximates a linear gradient, with sequentially disperse polymers, whose sequences are created statistically to yield the appropriate ensemble average linear gradient. Especially at high segregation strength, we find clear differences in polymer conformations and microstructures between these systems. Importantly, the statistical polymers are able to find more favorable conformations given their sequence, for instance, a statistical polymer with a larger fraction of A than the median will tend towards the A lamellae. The conformations of the statistically different polymers can thus be less stretched, and these systems have higher overall density. Consequently, the lamellae formed by statistical polymers have smaller domain spacing with sharper interfaces.

  19. Design and Synthesis of Network-Forming Triblock Copolymers Using Tapered Block Interfaces

    Science.gov (United States)

    Kuan, Wei-Fan; Roy, Raghunath; Rong, Lixia; Hsiao, Benjamin S.; Epps, Thomas H.

    2012-01-01

    We report a strategy for generating novel dual-tapered poly(isoprene-b-isoprene/styrene-b-styrene-b-styrene/methyl methacrylate-b-methyl methacrylate) [P(I-IS-S-SM-M)] triblock copolymers that combines anionic polymerization, atom transfer radical polymerization (ATRP), and Huisgen 1,3-dipolar cycloaddition click chemistry. The tapered interfaces between blocks were synthesized via a semi-batch feed using programmable syringe pumps. This strategy allows us to manipulate the transition region between copolymer blocks in triblock copolymers providing control over the interfacial interactions in our nanoscale phase-separated materials independent of molecular weight and block constituents. Additionally, we show the ability to retain a desirous and complex multiply-continuous network structure (alternating gyroid) in our dual-tapered triblock material. PMID:23066522

  20. Analytical Model for the End-Bearing Capacity of Tapered Piles Using Cavity Expansion Theory

    Directory of Open Access Journals (Sweden)

    Suman Manandhar

    2012-01-01

    Full Text Available On the basis of evidence from model tests on increasing the end-bearing behavior of tapered piles at the load-settlement curve, this paper proposes an analytical spherical cavity expansion theory to evaluate the end-bearing capacity. The angle of tapering is inserted in the proposed model to evaluate the end-bearing capacity. The test results of the proposed model in different types of sands and different relative densities show good effects compared to conventional straight piles. The end-bearing capacity increases with increases in the tapering angle. The paper then propounds a model for prototypes and real-type pile tests which predicts and validates to evaluate the end-bearing capacity.

  1. [Application of hand-use ProTaper instruments in endodontic treatment of molar canals].

    Science.gov (United States)

    Ma, Sui-qi; Xie, Qian; Zhou, Yin-feng

    2010-07-01

    To evaluate the application of hand-use ProTaper instruments in endodontic treatment of molar canals. A total of 203 permanent molars were randomly divided into the experimental group (99 molars) and control group (104 molars) prepared by hand-use ProTaper instruments and standard stainless steel K-file, respectively. The molars in the two groups were obturated by cold lateral condensation technique. The root canal preparation and obturation were evaluated by radiograph, and the working time of preparation and post-operative emergencies were analyzed. The preparation time in the experimental group was obviously shorter than that in the control group (Phand-use ProTaper instruments may improve the effect of root canal treatment of the molars and shorten the working time and reduce the post-operative emergencies.

  2. Experimental stress–strain analysis of tapered silica optical fibers with nanofiber waist

    International Nuclear Information System (INIS)

    Holleis, S.; Hoinkes, T.; Wuttke, C.; Schneeweiss, P.; Rauschenbeutel, A.

    2014-01-01

    We experimentally determine tensile force–elongation diagrams of tapered optical fibers with a nanofiber waist. The tapered optical fibers are produced from standard silica optical fibers using a heat and pull process. Both, the force–elongation data and scanning electron microscope images of the rupture points indicate a brittle material. Despite the small waist radii of only a few hundred nanometers, our experimental data can be fully explained by a nonlinear stress–strain model that relies on material properties of macroscopic silica optical fibers. This is an important asset when it comes to designing miniaturized optical elements as one can rely on the well-founded material characteristics of standard optical fibers. Based on this understanding, we demonstrate a simple and non-destructive technique that allows us to determine the waist radius of the tapered optical fiber. We find excellent agreement with independent scanning electron microscope measurements of the waist radius

  3. Multipoint fiber-optic laser-ultrasonic actuator based on fiber core-opened tapers.

    Science.gov (United States)

    Tian, Jiajun; Dong, Xiaolong; Gao, Shimin; Yao, Yong

    2017-11-27

    In this study, a novel fiber-optic, multipoint, laser-ultrasonic actuator based on fiber core-opened tapers (COTs) is proposed and demonstrated. The COTs were fabricated by splicing single-mode fibers using a standard fiber splicer. A COT can effectively couple part of a core mode into cladding modes, and the coupling ratio can be controlled by adjusting the taper length. Such characteristics are used to obtain a multipoint, laser-ultrasonic actuator with balanced signal strength by reasonably controlling the taper lengths of the COTs. As a prototype, we constructed an actuator that generated ultrasound at four points with a balanced ultrasonic strength by connecting four COTs with coupling ratios of 24.5%, 33.01%, 49.51%, and 87.8% in a fiber link. This simple-to-fabricate, multipoint, laser-ultrasonic actuator with balanced ultrasound signal strength has potential applications in fiber-optic ultrasound testing technology.

  4. Generation of single-frequency tunable green light in a coupled ring tapered diode laser cavity

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Petersen, Paul Michael

    2013-01-01

    in the broad wavelength range from 1049 nm to 1093 nm and the beam propagation factor is improved from M2 = 2.8 to below 1.1. The laser frequency is automatically locked to the cavity resonance frequency using optical feedback. Furthermore, we show that this adaptive external cavity approach leads to efficient......We report the realization of a tapered diode laser operated in a coupled ring cavity that significantly improves the coherence properties of the tapered laser and efficiently generates tunable light at the second harmonic frequency. The tapered diode laser is tunable with single-frequency output...... frequency doubling. More than 500 mW green output power is obtained by placing a periodically poled LiNbO3 crystal in the external cavity. The single frequency green output from the laser system is tunable in the 530 nm to 533 nm range limited by the LiNbO3 crystal. The optical to optical conversion...

  5. Up-taper-based Mach-Zehnder interferometer for temperature and strain simultaneous measurement.

    Science.gov (United States)

    Kang, Zexin; Wen, Xiaodong; Li, Chao; Sun, Jiang; Wang, Jing; Jian, Shuisheng

    2014-04-20

    A novel all-fiber sensing configuration for simultaneous measurements of temperature and strain based on the up-taper Mach-Zehnder interferometer (MZI) with an in-line embedded fiber Bragg grating (FBG) is proposed and experimentally demonstrated. This configuration consists of two up-tapers fabricated by an excessive fusion splicing method and a short segment of inscribed FBG. Due to the different responses of the up-taper MZI and the FBG to the uniform variation of temperature and strain, the simultaneous measurement for these two variables could be achieved by real-time monitoring the transmission spectrum. For 0.01 nm wavelength resolution, a resolution of 0.311°C in temperature can be achieved, and the average strain resolution is 10.07 με.

  6. Cementless Hip Stem Anteversion in the Dysplastic Hip: A Comparison of Tapered Wedge vs Metaphyseal Filling.

    Science.gov (United States)

    Taniguchi, Naofumi; Jinno, Tetsuya; Koga, Daisuke; Hagino, Tetsuo; Okawa, Atsushi; Haro, Hirotaka

    2017-05-01

    Appropriate stem anteversion is important for achieving stability of the prosthetic joint in total hip arthroplasty. Anteversion of a cementless femoral stem is affected by the femoral canal morphology and varies according to stem geometry. We investigated the difference and variation of the increase in anteversion between 2 types of cementless stems, and the correlation between each stem and the preoperative femoral anteversion. We retrospectively compared 2 groups of hips that underwent total hip arthroplasty using a metaphyseal filling stem (78 hips) or a tapered wedge stem (83 hips). All the patients had osteoarthritis due to hip dysplasia. Computed tomography was used to measure preoperative femoral anteversion at 5 levels and postoperative stem anteversion. The increase in anteversion of the tapered wedge stem group (22.7° ± 11.6°) was more than that of the metaphyseal filling stem group (17.2° ± 8.3°; P = .0007). The variation of the increase in the tapered wedge stem group was significantly larger than that in the metaphyseal filling stem group (P = .0016). The metaphyseal filling stem group was more highly and positively correlated with femoral anteversion than the tapered wedge stem group. Femoral anteversion affects stem anteversion differently according to stem geometry. The tapered wedge stems had greater variation of the increase in anteversion than did the metaphyseal filling stems. Based on the results of this study, it is difficult to preoperatively estimate the increase in stem anteversion for tapered wedge stems. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Wavelength beam combining of a 980-nm tapered diode laser bar in an external cavity

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Thestrup Nielsen, Birgitte

    2010-01-01

    solution for preserving the beam quality of the bar in the range of that of a single emitter and at the same time, enabling the power scaling. We report spectral beam combining applied to a 12 emitter tapered laser bar at 980 nm. The external cavity has been designed for a wavelength separation of 4.0 nm......High power diode lasers are used in a large number of applications. A limiting factor for more widespread use of broad area lasers is the poor beam quality. Gain guided tapered diode lasers are ideal candidates for industrial applications that demands watt level output power with good beam quality...

  8. Brillouin lasing in single-mode tapered optical fiber with inscribed fiber Bragg grating array

    Directory of Open Access Journals (Sweden)

    S.M. Popov

    2018-06-01

    Full Text Available A tapered optical fiber has been manufactured with an array of fiber Bragg gratings (FBG inscribed during the drawing process. The total fiber peak reflectivity is 5% and the reflection bandwidth is ∼3.5 nm. A coherent frequency domain reflectometry has been applied for precise profiling of the fiber core diameter and grating reflectivity both distributed along the whole fiber length. These measurements are in a good agreement with the specific features of Brillouin lasing achieved in the semi-open fiber cavity configuration. Keywords: Tapered optical fibers, Fiber Bragg gratings, Random lasers

  9. Efficient Mid-Infrared Supercontinuum Generation in Tapered Large Mode Area Chalcogenide Photonic Crystal Fibers

    DEFF Research Database (Denmark)

    Petersen, Christian Rosenberg; Engelsholm, Rasmus Dybbro; Markos, Christos

    2017-01-01

    Mid-infrared supercontinuum spanning from 1.8-9  μm with an output power of 41.5 mW is demonstrated by pumping tapered large mode area chalcogenide photonic crystal fibers using a 4 μm optical parametric source.......Mid-infrared supercontinuum spanning from 1.8-9  μm with an output power of 41.5 mW is demonstrated by pumping tapered large mode area chalcogenide photonic crystal fibers using a 4 μm optical parametric source....

  10. High-frequency impedance of small-angle tapers and collimators

    Directory of Open Access Journals (Sweden)

    G. Stupakov

    2010-10-01

    Full Text Available Collimators and transitions in accelerator vacuum chambers often include small-angle tapering to lower the wakefields generated by the beam. While the low-frequency impedance is well described by Yokoya’s formula (for axisymmetric geometry, much less is known about the behavior of the impedance in the high-frequency limit. In this paper we develop an analytical approach to the high-frequency regime for round collimators and tapers. Our analytical results are compared with computer simulations using the code ECHO.

  11. Propagation of an intense laser beam in a tapered plasma channel

    International Nuclear Information System (INIS)

    Jha, Pallavi; Singh, Ram Gopal; Upadhyaya, Ajay K.; Mishra, Rohit K.

    2008-01-01

    Propagation characteristics and modulation instability of an intense laser beam propagating in an axially tapered plasma channel, having a parabolic radial density profile, are studied. Using the source-dependent expansion technique, the evolution equation for the laser spot is set up and conditions for propagation of the laser beam with a constant spot size (matched beam) are obtained. Further, the dispersion relation and growth rate of modulation instability of the laser pulse as it propagates through linearly and quadratically tapered plasma channels, have been obtained

  12. High force measurement sensitivity with fiber Bragg gratings fabricated in uniform-waist fiber tapers

    International Nuclear Information System (INIS)

    Wieduwilt, Torsten; Brückner, Sven; Bartelt, Hartmut

    2011-01-01

    Fiber Bragg gratings inscribed in the waist of tapered photosensitive fibers offer specific attractive properties for sensing applications. A small-diameter fiber reduces structural influences for imbedded fiber sensing elements. In the case of application as a force-sensing element for tensile forces, sensitivity scales inversely with the fiber cross-sectional area. It is therefore possible to increase force sensitivity by several orders of magnitude compared to Bragg grating sensors in conventionally sized fibers. Special requirements for such Bragg grating arrangements are discussed and experimental measurements for different fiber taper diameters down to 4 µm are presented

  13. Extraordinary optical transmission with tapered slits: effect of higher diffraction and slit resonance orders

    DEFF Research Database (Denmark)

    Sondergaard, T.; Bozhevolnyi, S. I.; Beermann, J.

    2012-01-01

    Transmission through thin metal films with a periodic arrangement of tapered slits is considered. Transmission maps covering a wide range of periods, film thicknesses, and taper angles are presented. The maps show resonant transmission when fundamental and higher-order slit resonances are excited...... to be in the range of 6 degrees-10 degrees. Both theory and experiments show split-peak spectra and shifted-peak spectra due to interference between a slit resonance and Rayleigh-Wood anomalies. (C) 2011 Optical Society of America...

  14. Widely Tunable High-Power Tapered Diode Laser at 1060 nm

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Sumpf, Bernd; Erbert, Götz

    2011-01-01

    We report a large tuning range from 1018 to 1093 nm from a InGaAs single quantum-well 1060-nm external cavity tapered diode laser. More than 2.5-W output power has been achieved. The tuning range is to our knowledge the widest obtained from a high-power InGaAs single quantum-well tapered laser...... operating around 1060 nm. The light emitted by the laser has a nearly diffraction limited beam quality and a narrow linewidth of less than 6 pm everywhere in the tuning range....

  15. 3.76 W of green light generated by intracavity frequency doubling of a 1081.5 nm Yb:GdYSiO2 laser with LiB3O5

    International Nuclear Information System (INIS)

    Zhang, D; Shao, Y; Liu, H P; Li, Y L; Tao, Z H; Ruan, Q R; Zhang, T Y

    2011-01-01

    Efficient continuous-wave (CW) intracavity frequency doubling of a diode-end-pumped Yb:GdYSiO 2 (Yb:GYSO) laser operating on 2 F 5/2 → 2 F 7/2 transitions at 1081.5 nm has been demonstrated. With 17.6 W of diode pump power and the frequency doubling crystal LiB 3 O 5 (LBO), a maximum output power of 3.76 W in the green spectral range at 541 nm has been achieved, corresponding to an optical-to-optical conversion efficiency of 21.4%; the output power stability over 30 min is better than 5%. To the best of our knowledge, this is first work on intracavity frequency doubling of a diode pumped Yb:GYSO laser at 1081.5 nm

  16. Experimental Measurement of the Static Coefficient of Friction at the Ti-Ti Taper Connection in Total Hip Arthroplasty

    NARCIS (Netherlands)

    Bitter, T.; Khan, I.; Marriott, T.; Schreurs, B.W.; Verdonschot, Nicolaas Jacobus Joseph; Janssen, D.

    2016-01-01

    The modular taper junction in total hip replacements has been implicated as a possible source of wear. The finite-element (FE) method can be used to study the wear potential at the taper junction. For such simulations it is important to implement representative contact parameters, in order to

  17. Evaluation of the Painful Dual Taper Modular Neck Stem Total Hip Arthroplasty: Do They All Require Revision?

    Science.gov (United States)

    Kwon, Young-Min

    2016-07-01

    Although dual taper modular-neck total hip arthroplasty (THA) design with additional neck-stem modularity has the potential to optimize hip biomechanical parameters by facilitating adjustments of leg length, femoral neck version and offset, there is increasing concern regarding this stem design as a result of the growing numbers of adverse local tissue reactions due to fretting and corrosion at the neck-stem taper junction. Implant factors such as taper cone angle, taper surface roughness, taper contact area, modular neck taper metallurgy, and femoral head size play important roles in influencing extent of taper corrosion. There should be a low threshold to conduct a systematic clinical evaluation of patients with dual-taper modular-neck stem THA using systematic risk stratification algorithms as early recognition and diagnosis will ensure prompt and appropriate treatment. Although specialized tests such as metal ion analysis and cross-sectional imaging modalities such as metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful in optimizing clinical decision-making, overreliance on any single investigative tool in the clinical decision-making process for revision surgery should be avoided. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Endodontic shaping performance using nickel-titanium hand and motor ProTaper systems by novice dental students.

    Science.gov (United States)

    Tu, Ming-Gene; Chen, San-Yue; Huang, Heng-Li; Tsai, Chi-Cheng

    2008-05-01

    Preparing a continuous tapering conical shape and maintaining the original shape of a canal are obligatory in root canal preparation. The purpose of this study was to compare the shaping performance in simulated curved canal resin blocks of the same novice dental students using hand-prepared and engine-driven nickel-titanium (NiTi) rotary ProTaper instruments in an endodontic laboratory class. Twenty-three fourth-year dental students attending China Medical University Dental School prepared 46 simulated curved canals in resin blocks with two types of NiTi rotary systems: hand and motor ProTaper files. Composite images were prepared for estimation. Material removed, canal width and canal deviation were measured at five levels in the apical 4 mm of the simulated curved canals using AutoCAD 2004 software. Data were analyzed using Wilcoxon's rank-sum test. The hand ProTaper group cut significantly wider than the motor rotary ProTaper group in the outer wall, except for the apical 0 mm point. The total canal width was cut significantly larger in the hand group than in the motor group. There was no significant difference between the two groups in centering canal shape, except at the 3 mm level. These findings show that the novice students prepared the simulated curved canal that deviated more outwardly from apical 1 mm to 4 mm using the hand ProTaper. The ability to maintain the original curvature was better in the motor rotary ProTaper group than in the hand ProTaper group. Undergraduate students, if following the preparation sequence carefully, could successfully perform canal shaping by motor ProTaper files and achieve better root canal geometry than by using hand ProTaper files within the same teaching and practicing sessions.

  19. Finite element modeling of small-scale tapered wood-laminated composite poles with biomimicry features

    Science.gov (United States)

    Cheng Piao; Todd F. Shupe; R.C. Tang; Chung Y. Hse

    2008-01-01

    Tapered composite poles with biomimicry features as in bamboo are a new generation of wood laminated composite poles that may some day be considered as an alternative to solid wood poles that are widely used in the transmission and telecommunication fields. Five finite element models were developed with ANSYS to predict and assess the performance of five types of...

  20. Truncated acoustic black hole structure with the optimized tapering shape and damping coating

    DEFF Research Database (Denmark)

    Ih, Jeong-Guon; Kim, Miseong; Lee, Ik Jin

    2016-01-01

    The acoustic black hole (ABH) structure can be an option as a vibration damper by providing a tapered wedge at the end of a beam or plate. However, not much work has been done on design to yield an effective ABH design for such a plate. We attempt to optimize the shape of the ABH to effectively...

  1. Comparison between Laser and Stamping without Die (SWD for Micro Tapered Hole Forming

    Directory of Open Access Journals (Sweden)

    Yung-Chou Hung

    2016-03-01

    Full Text Available The forming of a micro tapered hole is based on nanosecond pulsed laser processing, which conforms to fast processing time and high throughput; however, the microhole quality should be improved. Micro stamping is a technology providing high precise size and speed. The greatest difficulty in forming a microhole by micro stamping is the precision alignment of the punch head to the lower die. In order to overcome the difficulty, we proposed a concept of stamping without die (SWD. Without a lower die, the tapered punch head was directly applied to the workpiece for micro stamping, and a thicker workpiece surrounding the punching area provides a better support to the stamping process. Thus, a successful forming of micro tapered holes is completed. The micro tapered hole depth is 300 μm, and the maximum ratio of inlet to outlet diameter is 18:1. In order to reduce the number of experiments, the finite element analysis software DEFORM-3D was used for forming analysis. The simulation forecast result was compared with the experimental processing, which was well validated. Under different experimental parameters of laser energy and defocusing distance, drilling results by two methods show that the microhole quality by stamping process is better than by laser processing.

  2. Analysis the fatigue using pro taper rotary instruments durin instrumentation of extrated mandibular premolars. SEM observation.

    OpenAIRE

    Siragusa, Martha; Racciatti, Gabriela; García, María

    2007-01-01

    Recibido: Marzo 2007 Aceptado: Julio 2007 Siragusa, Martha; Racciatti, Gabriela y García, María. Analysis the fatigue using pro taper rotary instruments durin instrumentation of extrated mandibular premolars. SEM observation. Electronic Journal of Endodontics Rosario [Online], Volumen 2 Número 13. [octubre 2007]. http://www.endojournal.com.ar/journal/index.php/ejer/article/view/44. ISSN 1666-6143.

  3. Effects of Self-Adjusting File, Mtwo, and ProTaper on the root canal wall

    NARCIS (Netherlands)

    Hin, E.S.; Wu, M.K.; Wesselink, P.R.; Shemesh, H.

    2013-01-01

    Introduction The purpose of this ex vivo study was to observe the incidence of cracks in root dentin after root canal preparation with hand files, self-adjusting file (SAF), ProTaper, and Mtwo. Methods One hundred extracted mandibular premolars with single canals were randomly selected. Two

  4. Restorasi Resin Komposit Menggunakan Pasak Tapered Self Threading Pada Molar Ketiga Kiri Mandibula

    Directory of Open Access Journals (Sweden)

    Ellen Krisanti

    2013-06-01

    Composite Resin Restoration Using Tapered Self Threading Poston Left Mandibular Third Molar. Root canal morphology of mandibular third molar has more complex variation than the other molars. In third molar, the extraction teeth are often executed; however, the third molar can be maintained in other conditions. One visit root canal treatment is a therapy option for this case. The purpose of this case report is to show the success of one visit root canal treatment in third molar with pulp necrosis by restoring the composite resin through tapered self-treading post. A 20 year-old female patient who came to the Prof Soedomo RSGM, FKG UGM complained about the pain when chewing food on her third molar and positive in percussion. The radiographs showed that there was an incomplete restoration. There was a gap between cavities with restoration. The treatment plan for this case was one visit root canal treatment and composite resin with tapered self-threading post as final restoration. From the case, it can concluded that one visit root canal treatment results in a smaller chance for microorganism recontamination than the multi-visit in order to ensure the success of the treatment. Direct composite resin restoration with tapered self-threading dowel is an alternative restoration after endodontic treatment because it works out faster and more retentive.

  5. A high precision recipe for correcting images distorted by a tapered fiber optic

    International Nuclear Information System (INIS)

    Islam, M Sirajul; Kitchen, M J; Lewis, R A; Uesugi, K

    2010-01-01

    Images captured with a tapered fiber optic camera show significant spatial distortion mainly because the spatial orientation of the fiber bundles is not identical at each end of the taper. We present three different techniques for the automatic distortion correction of images acquired with a charge-coupled device (CCD) camera bonded to a tapered optical fiber. In this paper we report - (i) comparison of various methods for distortion correction (ii) extensive quantitative analysis of the techniques and (iii) experiments carried out using a high resolution fiber optic camera. A pinhole array was used to find control points in the distorted image space. These control points were then associated with their known true coordinates. To apply geometric correction, three different approaches were investigated - global polynomial fitting, local polynomial fitting and triangulated interpolation. Sub-pixel accuracy was achieved in all approaches, but the experimental results reveal that the triangulated interpolation gave the most satisfactory result for the distortion correction. The effect of proper alignment of the mask with the fiber optic taper (FOT) camera was also investigated. It was found that the overall dewarping error is minimal when the mask is almost parallel to the CCD.

  6. Optimization of the soliton self-frequency shift in a tapered photonic crystal fiber

    DEFF Research Database (Denmark)

    Judge, A.C.; Bang, Ole; Eggleton, B.J.

    2009-01-01

    nonuniform waists, an additional enhancement of the SSFS is achieved by varying the taper waist diameter along its length in a carefully designed fashion in order to present an optimal level of group-velocity dispersion to the soliton at each point, thus avoiding the spectral recoil due to the emission...

  7. Scaling relations for soliton compression and dispersive-wave generation in tapered optical fibers

    DEFF Research Database (Denmark)

    Lægsgaard, Jesper

    2018-01-01

    In this paper, scaling relations for soliton compression in tapered optical fibers are derived and discussed. The relations allow simple and semi-accurate estimates of the compression point and output noise level, which is useful, for example, for tunable dispersive-wave generation with an agile ...

  8. Modifying Taper-Derived Merchantable Height Estimates to Account for Tree Characteristics

    Science.gov (United States)

    James A. Westfall

    2006-01-01

    The U.S. Department of Agriculture Forest Service Northeastern Forest Inventory and Analysis program (NE-FIA) is developing regionwide tree-taper equations. Unlike most previous work on modeling tree form, this effort necessarily includes a wide array of tree species. For some species, branching patterns can produce undesirable tree form that reduces the merchantable...

  9. Controlling coarse woody debris inventory quality: taper and relative size methods

    Science.gov (United States)

    C.W. Woodall; J.A. Westfall

    2008-01-01

    Accurately measuring the dimensions of coarse woody debris (CWD) is critical for ensuring the quality of CWD estimates and, hence, for accurately estimating forest ecosystem attributes (e.g., CWD carbon stocks). To improve the quality of CWD dimensional measurements, the distribution of taper (ratio of change in diameter and length) and relative size (RS; ratio of...

  10. Tapered Microfluidic for Continuous Micro-Object Separation Based on Hydrodynamic Principle.

    Science.gov (United States)

    Ahmad, Ida Laila; Ahmad, Mohd Ridzuan; Takeuchi, Masaru; Nakajima, Masahiro; Hasegawa, Yasuhisa

    2017-12-01

    Recent advances in microfluidic technologies have created a demand for a simple and efficient separation intended for various applications such as food industries, biological preparation, and medical diagnostic. In this paper, we report a tapered microfluidic device for passive continuous separation of microparticles by using hydrodynamic separation. By exploiting the hydrodynamic properties of the fluid flow and physical characteristics of micro particles, effective size based separation is demonstrated. The tapered microfluidic device has widening geometries with respect to specific taper angle which amplify the sedimentation effect experienced by particles of different sizes. A mixture of 3-μm and 10-μm polystyrene microbeads are successfully separated using 20° and 25° taper angles. The results obtained are in agreement with three-dimensional finite element simulation conducted using Abaqus 6.12. Moreover, the feasibility of this mechanism for biological separation is demonstrated by using polydisperse samples consists of 3-μm polystyrene microbeads and human epithelial cervical carcinoma (HeLa) cells. 98% of samples purity is recovered at outlet 1 and outlet 3 with flow rate of 0.5-3.0 μl/min. Our device is interesting despite adopting passive separation approach. This method enables straightforward, label-free, and continuous separation of multiparticles in a stand-alone device without the need for bulky apparatus. Therefore, this device may become an enabling technology for point of care diagnosis tools and may hold potential for micrototal analysis system applications.

  11. Design of Ultra-Wideband Tapered Slot Antenna by Using Binomial Transformer with Corrugation

    Science.gov (United States)

    Chareonsiri, Yosita; Thaiwirot, Wanwisa; Akkaraekthalin, Prayoot

    2017-05-01

    In this paper, the tapered slot antenna (TSA) with corrugation is proposed for UWB applications. The multi-section binomial transformer is used to design taper profile of the proposed TSA that does not involve using time consuming optimization. A step-by-step procedure for synthesis of the step impedance values related with step slot widths of taper profile is presented. The smooth taper can be achieved by fitting the smoothing curve to the entire step slot. The design of TSA based on this method yields results with a quite flat gain and wide impedance bandwidth covering UWB spectrum from 3.1 GHz to 10.6 GHz. To further improve the radiation characteristics, the corrugation is added on the both edges of the proposed TSA. The effects of different corrugation shapes on the improvement of antenna gain and front-to-back ratio (F-to-B ratio) are investigated. To demonstrate the validity of the design, the prototypes of TSA without and with corrugation are fabricated and measured. The results show good agreement between simulation and measurement.

  12. A mechanical model of wing and theoretical estimate of taper factor ...

    Indian Academy of Sciences (India)

    Likewise, by using the data linear regression and curve estimation method, as well as estimating the taper factors and the angle between the humerus and the body, we calculated the relationship between wingspan, wing area and the speed necessary to meet the aerodynamic requirements of sustained flight. In addition ...

  13. Duodenal Derotation and Extent Tapering Jejunoplasty as Primary Repair for Neonates With High Jejunal Atresia

    Directory of Open Access Journals (Sweden)

    Chih-Cheng Luo

    2010-10-01

    Conclusion: In very proximal high atresia, the extent of tapering is limited by the proximity of the ligament of Treitz. Duodenal derotation provides better access to the high atresia. The results of this limited experience suggest that the DDETJ procedure could provide an alternative therapy in patients with high jejunal atresia.

  14. Efficient synthesis of large-scale thinned arrays using a density-taper initialised genetic algorithm

    CSIR Research Space (South Africa)

    Du Plessis, WP

    2011-09-01

    Full Text Available The use of the density-taper approach to initialise a genetic algorithm is shown to give excellent results in the synthesis of thinned arrays. This approach is shown to give better SLL values more consistently than using random values and difference...

  15. Taper-based system for estimating stem volumes of upland oaks

    Science.gov (United States)

    Donald E. Hilt

    1980-01-01

    A taper-based system for estimating stem volumes is developed for Central States upland oaks. Inside bark diameters up the stem are predicted as a function of dbhib, total height, and powers and relative height. A Fortran IV computer program, OAKVOL, is used to predict cubic and board-foot volumes to any desired merchantable top dib. Volumes of...

  16. Effects of Prosthesis Stem Tapers on Stress Distribution of Cemented Hip Arthroplasty

    International Nuclear Information System (INIS)

    Abdullah, Abdul Halim; Nor, Mohd Asri Mohd; Saman, Alias Mohd; Tamin, Mohd Nasir; Kadir, Mohammed Rafiq Abdul

    2010-01-01

    Aseptic loosening effects are critical issues in encouraging long term stability of cemented hip arthroplasty. Stress shielding is believed to be an important factor that contributes to the aseptic loosening problems. The numerous changes in the prosthesis stem design are intended to minimize the stress shielding and aseptic loosening problems and to improve the long term performance of the implants. In this study, the stress distribution in cemented hip arthroplasty is established using finite element method. The taper of the prosthesis is designed to be 3 deg. at anterior/posterior, 3 deg. at medial/lateral and 10 deg. from wide lateral to narrow medial. Major muscle loads and contact forces are simulated for walking (toe-off phase) and stair climbing load cases. Effects of prosthesis stem tapers on the resulting stress distribution are investigated. Results show that compressive stress dominates in the medial plane while tensile stress in the lateral plane of the femur. The corresponding stress levels of intact femur for walking and stair-climbing load cases are 22 and 29 MPa, respectively. The magnitude of Tresca stress for the THA femur in stair-climbing load case remains higher in the region of 85 MPa while the walking load case induces around 40 MPa. The stress range in the straight and single taper stem prosthesis is lower than 260 MPa, while localized Tresca stress is in the order of the yield strength of Ti-6Al-4V alloy for double and triple taper stem design.

  17. Simulation and analysis of sensitivity for tapered fiber Bragg grating evanescent wave sensor

    Science.gov (United States)

    Xu, Hong-zhi; Lou, Jun; Tan, Yao-cheng; Li, Ben-chong; Huang, Jie; Shen, Wei-min

    2014-12-01

    We have carried out a detailed simulative study of the tapered fiber Bragg grating (TFBG) evanescent wave sensor sensitivity by using 3-D Coupled-Mode Theory method. The method is based on the spectral interrogation mode of operation. We also make numerical simulations to figure out how the uniform waist diameter and the difference of the relative refractive indexes between fiber core and external medium affect the sensitivity of this proposed sensor. The simulation results show that the sensitivity of the tapered fiber Bragg grating will be improved when the diameter of the uniform waist decrease as well as the difference of the relative refractive indexes between fiber core and external medium. And with the fixed uniform waist diameter and tapered length, when the difference of the relative refractive index of fiber core and external medium varies is 0.015RIU, the values of wavelength shift is 5.08nm, the sensitivity of the tapered fiber Bragg grating is 317.5nm/RIU. The sensitivity is higher than that of the common FBG. The results are consistent with theoretical models. The simulation results can supply the guidance for the further experimental study and refractive index sensor design, optimization and application.

  18. Continuous deep reactive ion etching of tapered via holes for three-dimensional integration

    NARCIS (Netherlands)

    Li, R.; Lamy, Y.; Besling, W.F.A.; Roozeboom, F.; Sarro, P.M.

    2008-01-01

    A continuous SF6/O2 plasma process at room temperature has been used to etch tapered through-silicon vias using a DRIE-ICP tool. These features (10–100 µm in diameter) are aimed for applications in 3D integration and MEMS packaging. The effects of various process parameters such as O2 flow rate,

  19. Biorheological Model on Flow of Herschel-Bulkley Fluid through a Tapered Arterial Stenosis with Dilatation.

    Science.gov (United States)

    Priyadharshini, S; Ponalagusamy, R

    2015-01-01

    An analysis of blood flow through a tapered artery with stenosis and dilatation has been carried out where the blood is treated as incompressible Herschel-Bulkley fluid. A comparison between numerical values and analytical values of pressure gradient at the midpoint of stenotic region shows that the analytical expression for pressure gradient works well for the values of yield stress till 2.4. The wall shear stress and flow resistance increase significantly with axial distance and the increase is more in the case of converging tapered artery. A comparison study of velocity profiles, wall shear stress, and flow resistance for Newtonian, power law, Bingham-plastic, and Herschel-Bulkley fluids shows that the variation is greater for Herschel-Bulkley fluid than the other fluids. The obtained velocity profiles have been compared with the experimental data and it is observed that blood behaves like a Herschel-Bulkley fluid rather than power law, Bingham, and Newtonian fluids. It is observed that, in the case of a tapered stenosed tube, the streamline pattern follows a convex pattern when we move from r/R = 0 to r/R = 1 and it follows a concave pattern when we move from r/R = 0 to r/R = -1. Further, it is of opposite behaviour in the case of a tapered dilatation tube which forms new information that is, for the first time, added to the literature.

  20. Biorheological Model on Flow of Herschel-Bulkley Fluid through a Tapered Arterial Stenosis with Dilatation

    Directory of Open Access Journals (Sweden)

    S. Priyadharshini

    2015-01-01

    Full Text Available An analysis of blood flow through a tapered artery with stenosis and dilatation has been carried out where the blood is treated as incompressible Herschel-Bulkley fluid. A comparison between numerical values and analytical values of pressure gradient at the midpoint of stenotic region shows that the analytical expression for pressure gradient works well for the values of yield stress till 2.4. The wall shear stress and flow resistance increase significantly with axial distance and the increase is more in the case of converging tapered artery. A comparison study of velocity profiles, wall shear stress, and flow resistance for Newtonian, power law, Bingham-plastic, and Herschel-Bulkley fluids shows that the variation is greater for Herschel-Bulkley fluid than the other fluids. The obtained velocity profiles have been compared with the experimental data and it is observed that blood behaves like a Herschel-Bulkley fluid rather than power law, Bingham, and Newtonian fluids. It is observed that, in the case of a tapered stenosed tube, the streamline pattern follows a convex pattern when we move from r/R=0 to r/R=1 and it follows a concave pattern when we move from r/R=0 to r/R=-1. Further, it is of opposite behaviour in the case of a tapered dilatation tube which forms new information that is, for the first time, added to the literature.

  1. Techniques for chamfer and taper grinding of oxide fuel pellets (LWBR Development Program)

    International Nuclear Information System (INIS)

    Johnson, R.G.R.; Allison, J.W.

    1981-10-01

    Floor mounted centerless grinding machines were adapted for shaping the edges of cylindrical oxide fuel pellets for the Light Water Breeder Reactor (LWBR) by plunge grinding. Edge configurations consisted of chamfers, either 0.015 inch x 45 0 or 0.006 inch x 45 0 , or tapers 0.150 inch long x .0025 inch deep. Grinding was done by plunging the pellet against a shaped grinding wheel which ground both the diameter to the required size and shaped the edges of the pellet. Two plunges per pellet were required to complete the operation. Separate wheels were needed for grinding either a chamfer or a taper, the set up was adjustable to vary the size of the chamfer or taper as needed. The set up also had the flexibility to accommodate the multiple pellet lengths and diameters required by the LWBR design. Tight manufacturing tolerances in the chamfer and taper dimensions required the use of dimensional control charts and statistical sampling plans as process controls

  2. Adalimumab Dose Tapering in Psoriasis: Predictive Factors for Maintenance of Complete Clearance.

    Science.gov (United States)

    Hansel, Katharina; Bianchi, Leonardo; Lanza, Francesco; Bini, Vittorio; Stingeni, Luca

    2017-03-10

    Psoriasis can be managed successfully with long-term biologics. Real-life clinical practice may require dose tapering as a therapeutic option to reduce the risk of drug-exposure and to increase cost-effectiveness. The responsiveness to extended intervals between adalimumab doses and the possible predictive factors of maintenance of complete clearance were studied in a retrospective 7-year single-centre analysis. Thirty patients who achieved complete clearance with adalimumab underwent dose tapering, progressively extending between-dose intervals (to 21-28 days). Sixty percent of subjects (group A) maintained complete clearance, whereas 40.0% (group B) relapsed and were switched back to the standard dosage to re-achieve complete clearance. Body mass index (BMI) and time to achieve Psoriasis Area Severity Index (PASI-100) with adalimumab standard treatment before dose tapering were significantly lower in group A than in group B (multi-variate Cox regression: p < 0.05, Kaplan-Meier analysis: p < 0.001, respectively). This study suggests that patients with lower BMI and shorter time to achieve PASI-100 with adalimumab standard dose were significantly more likely to be candidates for dose tapering.

  3. 980 nm tapered lasers with photonic crystal structure for low vertical divergence

    Science.gov (United States)

    Ma, Xiaolong; Qu, Hongwei; Zhao, Pengchao; Liu, Yun; Zheng, Wanhua

    2016-10-01

    High power tapered lasers with nearly diffraction-limited beam quality have attracted much attention in numerous applications such as nonlinear frequency conversion, optical pumping of solid-state and fiber lasers, medical treatment and others. However, the large vertical divergence of conventional tapered lasers is a disadvantage, which makes beam shaping difficult and expensive in applications. Diode lasers with photonic crystal structure can achieve a large mode size and a narrow vertical divergence. In this paper, we present tapered lasers with photonic crystal structure emitting at 980 nm. The epitaxial layer is grown using metal organic chemical vapor deposition. The device has a total cavity length of 2 mm, which consists of a 400-um long ridge-waveguide section and a 1600-um long tapered section. The taper angle is 4°. An output power of 3.3 W is achieved with a peak conversion efficiency of 35% in pulsed mode. The threshold current is 240 mA and the slope efficiency is 0.78 W/A. In continuous wave mode, the output power is 2.87 W, which is limited by a suddenly failure resulting from catastrophic optical mirror damage. The far field divergences with full width at half maximum are 12.3° in the vertical direction and 2.9° in the lateral direction at 0.5 A. At high injection level the vertical divergence doesn't exceed 16°. Beam quality factor M2 is measured based on second moment definition in CW mode. High beam quality is demonstrated by M2 value of less than 2 in both vertical and lateral directions.

  4. Femtosecond Cr:LiSAF and Cr:LiCAF lasers pumped by tapered diode lasers.

    Science.gov (United States)

    Demirbas, Umit; Schmalz, Michael; Sumpf, Bernd; Erbert, Götz; Petrich, Gale S; Kolodziejski, Leslie A; Fujimoto, James G; Kärtner, Franz X; Leitenstorfer, Alfred

    2011-10-10

    We report compact, low-cost and efficient Cr:Colquiriite lasers that are pumped by high brightness tapered laser diodes. The tapered laser diodes provided 1 to 1.2 W of output power around 675 nm, at an electrical-to-optical conversion efficiency of about 30%. Using a single tapered diode laser as the pump source, we have demonstrated output powers of 500 mW and 410 mW together with slope efficiencies of 47% and 41% from continuous wave (cw) Cr:LiSAF and Cr:LiCAF lasers, respectively. In cw mode-locked operation, sub-100-fs pulse trains with average power between 200 mW and 250 mW were obtained at repetition rates around 100 MHz. Upon pumping the Cr:Colquiriite lasers with two tapered laser diodes (one from each side of the crystal), we have observed scaling of cw powers to 850 mW in Cr:LiSAF and to 650 mW in Cr:LiCAF. From the double side pumped Cr:LiCAF laser, we have also obtained ~220 fs long pulses with 5.4 nJ of pulse energy at 77 MHz repetition rate. These are the highest energy levels reported from Cr:Colquiriite so far at these repetition rates. Our findings indicate that tapered diodes in the red spectral region are likely to become the standard pump source for Cr:Colquiriite lasers in the near future. Moreover, the simplified pumping scheme might facilitate efficient commercialization of Cr:Colquiriite systems, bearing the potential to significantly boost applications of cw and femtosecond lasers in this spectral region (750-1000 nm).

  5. Efficacy of ProTaper universal retreatment files in removing filling materials during root canal retreatment.

    Science.gov (United States)

    Giuliani, Valentina; Cocchetti, Roberto; Pagavino, Gabriella

    2008-11-01

    The aim of this study was to evaluate the efficacy of the ProTaper Universal System rotary retreatment system and of Profile 0.06 and hand instruments (K-file) in the removal of root filling materials. Forty-two extracted single-rooted anterior teeth were selected. The root canals were enlarged with nickel-titanium (NiTi) rotary files, filled with gutta-percha and sealer, and randomly divided into 3 experimental groups. The filling materials were removed with solvent in conjunction with one of the following devices and techniques: the ProTaper Universal System for retreatment, ProFile 0.06, and hand instruments (K-file). The roots were longitudinally sectioned, and the image of the root surface was photographed. The images were captured in JPEG format; the areas of the remaining filling materials and the time required for removing the gutta-percha and sealer were calculated by using the nonparametric one-way Kruskal-Wallis test and Tukey-Kramer tests, respectively. The group that showed better results for removing filling materials was the ProTaper Universal System for retreatment files, whereas the group of ProFile rotary instruments yielded better root canal cleanliness than the hand instruments, even though there was no statistically significant difference. The ProTaper Universal System for retreatment and ProFile rotary instruments worked significantly faster than the K-file. The ProTaper Universal System for retreatment files left cleaner root canal walls than the K-file hand instruments and the ProFile Rotary instruments, although none of the devices used guaranteed complete removal of the filling materials. The rotary NiTi system proved to be faster than hand instruments in removing root filling materials.

  6. Electroacupuncture for tapering off long-term benzodiazepine use: study protocol of randomized controlled trial.

    Science.gov (United States)

    Yeung, Wing-Fai; Chung, Ka-Fai; Zhang, Zhang-Jin; Chan, Wai-Chi; Zhang, Shi-Ping; Ng, Roger Man-Kin; Chan, Connie Lai-Wah; Ho, Lai-Ming; Yu, Yee-Man; Lao, Li-Xing

    2017-03-31

    Conventional approaches for benzodiazepine tapering have their limitations. Anecdotal studies have shown that acupuncture is a potential treatment for facilitating successful benzodiazepine tapering. As of today, there was no randomized controlled trial examining its efficacy and safety. The purpose of the study is to evaluate the efficacy of using electroacupuncture as an adjunct treatment to gradual tapering of benzodiazepine doses in complete benzodiazepine cessation in long-term benzodiazepine users. The study protocol of a randomized, assessor- and subject-blinded, controlled trial is presented. One hundred and forty-four patients with histories of using benzodiazepines in ≥50% of days for more than 3 months will be randomly assigned in a 1:1 ratio to receive either electroacupuncture or placebo electroacupuncture combined with gradual benzodiazepine tapering schedule. Both experimental and placebo treatments will be delivered twice per week for 4 weeks. Major assessments will be conducted at baseline, week 6 and week 16 post-randomization. Primary outcome is the cessation rate of benzodiazepine use. Secondary outcomes include the percentage change in the doses of benzodiazepine usage and the severity of withdrawal symptoms experienced based on the Benzodiazepine Withdrawal Symptom Questionnaire, insomnia as measured by the Insomnia Severity Index, and anxiety and depressive symptoms as evaluated by the Hospital Anxiety and Depression Scale. Adverse events will also be measured at each study visit. Results of this study will provide high quality evidence of the efficacy and safety of electroacupuncture as an adjunct treatment for benzodiazepine tapering in long-term users. ClinicalTrials.gov NCT02475538 .

  7. Friction Stir Welding of Tapered Thickness Welds Using an Adjustable Pin Tool

    Science.gov (United States)

    Adams, Glynn; Venable, Richard; Lawless, Kirby

    2003-01-01

    Friction stir welding (FSW) can be used for joining weld lands that vary in thickness along the length of the weld. An adjustable pin tool mechanism can be used to accomplish this in a single-pass, full-penetration weld by providing for precise changes in the pin length relative to the shoulder face during the weld process. The difficulty with this approach is in accurately adjusting the pin length to provide a consistent penetration ligament throughout the weld. The weld technique, control system, and instrumentation must account for mechanical and thermal compliances of the tooling system to conduct tapered welds successfully. In this study, a combination of static and in-situ measurements, as well as active control, is used to locate the pin accurately and maintain the desired penetration ligament. Frictional forces at the pin/shoulder interface were a source of error that affected accurate pin position. A traditional FSW pin tool design that requires a lead angle was used to join butt weld configurations that included both constant thickness and tapered sections. The pitch axis of the tooling was fixed throughout the weld; therefore, the effective lead angle in the tapered sections was restricted to within the tolerances allowed by the pin tool design. The sensitivity of the FSW process to factors such as thickness offset, joint gap, centerline offset, and taper transition offset were also studied. The joint gap and the thickness offset demonstrated the most adverse affects on the weld quality. Two separate tooling configurations were used to conduct tapered thickness welds successfully. The weld configurations included sections in which the thickness decreased along the weld, as well as sections in which the thickness increased along the weld. The data presented here include weld metallography, strength data, and process load data.

  8. Effect of ripple taper on band-gap overlap in a coaxial Bragg structure operating at terahertz frequency

    International Nuclear Information System (INIS)

    Ding Xueyong; Li Hongfan; Lv Zhensu

    2012-01-01

    Based on the mode-coupling method, numerical analysis is presented to demonstrate the influence of ripple taper on band-gap overlap in a coaxial Bragg structure operating at terahertz frequency. Results show that the interval between the band-gaps of the competing mode and the desired working mode is narrowed by use of positive-taper ripples, but is expanded if negative-taper ripples are employed, and the influence of the negative-taper ripples is obviously more advantageous than the positive-taper ripples; the band-gap overlap of modes can be efficiently separated by use of negative-taper ripples. The residual side-lobes of the frequency response in a coaxial Bragg structure with ripple taper also can be effectively suppressed by employing the windowing-function technique. These peculiarities provide potential advantage in constructing a coaxial Bragg cavity with high quality factor for single higher-order-mode operation of a high-power free-electron maser in the terahertz frequency range.

  9. The relationship between diameter and taper of nickel-titanium rotary instruments on the torsional resistance to fracture

    Directory of Open Access Journals (Sweden)

    Erick Miranda Souza

    Full Text Available Objective: To evaluate the resistance to fracture of rotary Ni-Ti files of various diameters and tapers after torsional stress simulation. Methods: Profile (Dentsply Maillerfer, Ballaigues, Suíça instruments sizes 15 to 40, taper 0.04 and 0.06 were used. Ten instruments of each size and taper were tested, totaling 120 files. The maximum torque (Tmax until fracture was determined in accordance with the ANSI / ADA Protocol Nº 28 . The maximum force was converted into maximum torque using the formula: Tmax = Loadmax x RadiusResults: The diameter (p<0.001 and taper (p<0.001 influenced the maximum torque to fracture. With the increase in diameter and taperthere was a gradual increase in the maximum torque. Using the multiple regression method an equation relating the maximum torque to the diameter (D and the taper (T was found: Tmax = -1.4 + 0.08D + 10.5T. Conclusion: The increase in diameter and taper promoted an increase in resistance to torsion. The variation of the taper from 0.04 to 0.06 in instruments with the same diameter increased resistance to fracture by torsion by around 25%.

  10. THE EFFECT OF TAPERING PERIOD ON PLASMA PRO-INFLAMMATORY CYTOKINE LEVELS AND PERFORMANCE IN ELITE MALE CYCLISTS

    Directory of Open Access Journals (Sweden)

    Peter M. Tiidus

    2009-12-01

    Full Text Available The aim of this study was to investigate the effect of two different tapering period lengths on the concentration of plasma interleukin- 6 (IL-6, interleukin (IL-1β and tumor necrosis factor-? (TNF-α and performance in elite male cyclists. To this end, after completing 8 weeks progressive endurance exercise, twenty four high-level endurance cyclists were randomly assigned to one of two groups: a control group of cyclists (n = 12 continued performing progressive weekly training volume for 3 weeks while a taper group of cyclists (n = 12 proceeded with a 50% reduction in weekly training volume relative to the control group. A simulated 40 min time trial (40TT performance ride was used as the criterion index of performance before and after the tapering period to evaluate the physiological and performance effects of each protocol. Blood samples were collected immediately post-40TT from all participants at the beginning of week 1, and the end of weeks 4, 8, 9 and 11. IL-1β, IL-6 and TNFα were assayed using a standard commercial ELISA kits (Quantikine; R & D Systems, Minneapolis, MN. The mean time to complete the 40TT in the taper group decreased significantly (p < 0.01 after both 1 and 3 weeks with reduced training volume relative to the control group. There were significant reductions in (p < 0.001 IL-1β, IL-6 and TNFα concentrations in the taper group relative to the control group at the end of the 3 week tapering period, but not at the end of the 1 week tapering period. These results demonstrate that both a 1 and a 3 week taper period will result in improved physical performance in trained cyclists but only a 3 week taper period will result in attenuation of post-exercise pro- inflammatory cytokines when compared to those continuing a more intense training regimen

  11. Dynamical modeling and experiment for an intra-cavity optical parametric oscillator pumped by a Q-switched self-mode-locking laser

    Science.gov (United States)

    Wang, Jing; Liu, Nianqiao; Song, Peng; Zhang, Haikun

    2016-11-01

    The rate-equation-based model for the Q-switched mode-locking (QML) intra-cavity OPO (IOPO) is developed, which includes the behavior of the fundamental laser. The intensity fluctuation mechanism of the fundamental laser is first introduced into the dynamics of a mode-locking OPO. In the derived model, the OPO nonlinear conversion is considered as a loss for the fundamental laser and thus the QML signal profile originates from the QML fundamental laser. The rate equations are solved by a digital computer for the case of an IOPO pumped by an electro-optic (EO) Q-switched self-mode-locking fundamental laser. The simulated results for the temporal shape with 20 kHz EO repetition and 11.25 W pump power, the signal average power, the Q-switched pulsewidth and the Q-switched pulse energy are obtained from the rate equations. The signal trace and output power from an EO QML Nd3+: GdVO4/KTA IOPO are experimentally measured. The theoretical values from the rate equations agree with the experimental results well. The developed model explains the behavior, which is helpful to system optimization.

  12. Tunable, continuous-wave, ultraviolet source based on intracavity sum-frequency-generation in an optical parametric oscillator using BiB₃O₆.

    Science.gov (United States)

    Devi, Kavita; Kumar, S Chaitanya; Ebrahim-Zadeh, M

    2013-10-21

    We report a continuous-wave (cw) source of tunable radiation across 333-345 nm in the ultraviolet (UV) using bismuth triborate, BiB₃O₆ (BIBO) as the nonlinear gain material. The source is based on internal sum-frequency-generation (SFG) in a cw singly-resonant optical parametric oscillator (OPO) pumped at 532 nm. The compact tunable source employs a 30-mm-long MgO:sPPLT crystal as the OPO gain medium and a 5-mm-long BIBO crystal for intracavity SFG of the signal and pump, providing up to 21.6 mW of UV power at 339.7 nm, with >15 mW over 64% of the SFG tuning range. The cw OPO is also tunable across 1158-1312 nm in the idler, delivering as much as 1.7 W at 1247 nm, with >1W over 65% of the tuning range. The UV output at maximum power exhibits passive power stability better than 3.4% rms and frequency stability of 193 GHz over more than one minute.

  13. Effect of cyclic torsional preloading on cyclic fatigue resistance of ProTaper Next and Mtwo nickel–titanium instruments

    Directory of Open Access Journals (Sweden)

    Eugenio Pedullà

    2015-06-01

    Conclusions: Torsional preloads reduced the cyclic fatigue resistance of M-wire and conventional (as ProTaper Next and Mtwo NiTi rotary instruments except for Mtwo with 25% or 50% of torsional preloading.

  14. 78 FR 58996 - Tapered Roller Bearings from the People's Republic of China: Notice of Court Decision Not in...

    Science.gov (United States)

    2013-09-25

    ... Sawblades Mfrs. Coalition v. United States, 626 F.3d 1374 (Fed. Cir. 2010) (``Diamond Sawblades''), the... a complaint with the CIT to challenge various aspects of the Final Results. \\2\\ Tapered Roller...

  15. On the dynamics of tapered vibro-impacting cantilever with tip mass

    Energy Technology Data Exchange (ETDEWEB)

    Gandhi, P. S.; Vyas, Vishal [Suman Mashruwala Advanced Microengineering Laboratory, Dept. of Mechanical Engineering, Indian Institute of Technology - Bombay, Mumai (India)

    2017-01-15

    This paper explores nonlinear dynamic behavior of vibro-impacting tapered cantilever with tip mass with regard to frequency response analysis. A typical frequency response curve of vibro-impacting beams displays well-known resonance frequency shift along with a hysteric jump and drop phenomena. We did a comprehensive parametric analysis capturing the effects of taper, tip-mass, stop location, and gap on the non-smooth frequency response. Analysis is presented in a non-dimensional form useful for other similar cases. Simulation results are further validated with corresponding experimental results for a few cases. Illustrative comparison of simulation results for varying parameters brings out several interesting aspects of variation in the nonlinear behavior.

  16. Free Vibration and Stability of Axially Functionally Graded Tapered Euler-Bernoulli Beams

    Directory of Open Access Journals (Sweden)

    Ahmad Shahba

    2011-01-01

    Full Text Available Structural analysis of axially functionally graded tapered Euler-Bernoulli beams is studied using finite element method. A beam element is proposed which takes advantage of the shape functions of homogeneous uniform beam elements. The effects of varying cross-sectional dimensions and mechanical properties of the functionally graded material are included in the evaluation of structural matrices. This method could be used for beam elements with any distributions of mass density and modulus of elasticity with arbitrarily varying cross-sectional area. Assuming polynomial distributions of modulus of elasticity and mass density, the competency of the element is examined in stability analysis, free longitudinal vibration and free transverse vibration of double tapered beams with different boundary conditions and the convergence rate of the element is then investigated.

  17. Wavelength interrogation of fiber Bragg grating sensors using tapered hollow Bragg waveguides.

    Science.gov (United States)

    Potts, C; Allen, T W; Azar, A; Melnyk, A; Dennison, C R; DeCorby, R G

    2014-10-15

    We describe an integrated system for wavelength interrogation, which uses tapered hollow Bragg waveguides coupled to an image sensor. Spectral shifts are extracted from the wavelength dependence of the light radiated at mode cutoff. Wavelength shifts as small as ~10  pm were resolved by employing a simple peak detection algorithm. Si/SiO₂-based cladding mirrors enable a potential operational range of several hundred nanometers in the 1550 nm wavelength region for a taper length of ~1  mm. Interrogation of a strain-tuned grating was accomplished using a broadband amplified spontaneous emission (ASE) source, and potential for single-chip interrogation of multiplexed sensor arrays is demonstrated.

  18. Canal Centring Ability of ProTaper and Mtwo Rotary Systems in Curved Canals

    Directory of Open Access Journals (Sweden)

    Turkaydin Dilek Erbay

    2014-07-01

    Full Text Available The purpose of this investigation was to compare centring ratio of ProTaper and Mtwo rotary systems. 60 mandibular molar teeth which had 25, 30 and 35 degree curvature in mesio-buccal root canal were used. Group 1 had 25°, Group 2 had 30°, and Group 3 had 35° curvatures. The roots were sectioned horizontally at 2 mm away from the apex. The apical region was then observed under a stereo-microscope. In each group, teeth were instrumented using ProTaper and Mtwo systems. After canal preparation, digital images of apical part of canals were taken. These images were then superimposed by using Adobe Photoshop CS2 programme. The data were analyzed using ANOVA and Student’s t-test.

  19. 200-W single frequency laser based on short active double clad tapered fiber

    Science.gov (United States)

    Pierre, Christophe; Guiraud, Germain; Yehouessi, Jean-Paul; Santarelli, Giorgio; Boullet, Johan; Traynor, Nicholas; Vincont, Cyril

    2018-02-01

    High power single frequency lasers are very attractive for a wide range of applications such as nonlinear conversion, gravitational wave sensing or atom trapping. Power scaling in single frequency regime is a challenging domain of research. In fact, nonlinear effect as stimulated Brillouin scattering (SBS) is the primary power limitation in single frequency amplifiers. To mitigate SBS, different well-known techniques has been improved. These techniques allow generation of several hundred of watts [1]. Large mode area (LMA) fibers, transverse acoustically tailored fibers [2], coherent beam combining and also tapered fiber [3] seem to be serious candidates to continue the power scaling. We have demonstrated the generation of stable 200W output power with nearly diffraction limited output, and narrow linewidth (Δν<30kHz) by using a tapered Yb-doped fiber which allow an adiabatic transition from a small purely single mode input to a large core output.

  20. Automated quantification of bronchiectasis, airway wall thickening and lumen tapering in chest CT

    DEFF Research Database (Denmark)

    Perez-Rovira, Adria; Kuo, Wieying; Petersen, Jens

    thickness and accompanying artery radius), and inter-branch Lumen-Ratio (LR, ratio between a branch's lumen and its parent branch lumen radius, a tapering measurement) were computed. Because CF-related structural abnormalities only affect a portion of branches, the 75th percentile was used as summarising......Purpose: To automatically quantify airway structural properties visualised on CT in children with cystic fibrosis (CF) and controls, including: bronchiectasis, airway wall thickening, and lumen tapering. Methods and materials: The 3D surface of the airway lumen, outer wall, and bronchial arteries...... were obtained using a fully automatic, in-house developed, segmentation method. Subsequently, for each detected airway branch, the Airway-Artery Ratio (AAR, ratio between airway outer wall and accompanying artery radius, a bronchiectasis measurement), Wall-Artery Ratio (WAR, ratio between airway wall...

  1. Analysis of the coupling efficiency of a tapered space receiver with a calculus mathematical model

    Science.gov (United States)

    Hu, Qinggui; Mu, Yining

    2018-03-01

    We establish a calculus mathematical model to study the coupling characteristics of tapered optical fibers in a space communications system, and obtained the coupling efficiency equation. Then, using MATLAB software, the solution was calculated. After this, the sample was produced by the mature flame-brush technique. The experiment was then performed, and the results were in accordance with the theoretical analysis. This shows that the theoretical analysis was correct and indicates that a tapered structure could improve its tolerance with misalignment. Project supported by The National Natural Science Foundation of China (grant no. 61275080); 2017 Jilin Province Science and Technology Development Plan-Science and Technology Innovation Fund for Small and Medium Enterprises (20170308029HJ); ‘thirteen five’ science and technology research project of the Department of Education of Jilin 2016 (16JK009).

  2. Modeling and optimization of kerf taper and surface roughness in laser cutting of titanium alloy sheet

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Arun Kumar; Dubey, Avanish Kumar [Motilal Nehru National Institute of Technology Allahabad, Uttar Pradesh (India)

    2013-07-15

    Laser cutting of titanium and its alloys is difficult due to it's poor thermal conductivity and chemical reactivity at elevated temperatures. But demand of these materials in different advanced industries such as aircraft, automobile and space research, require accurate geometry with high surface quality. The present research investigates the laser cutting process behavior of titanium alloy sheet (Ti-6Al-4V) with the aim to improve geometrical accuracy and surface quality by minimizing the kerf taper and surface roughness. The data obtained from L{sub 27} orthogonal array experiments have been used for developing neural network (NN) based models of kerf taper and surface roughness. A hybrid approach of neural network and genetic algorithm has been proposed and applied for the optimization of different quality characteristics. The optimization results show considerable improvements in both the quality characteristics. The results predicted by NN models are well in agreement with the experimental data.

  3. Efficient system modeling for a small animal PET scanner with tapered DOI detectors

    International Nuclear Information System (INIS)

    Zhang, Mengxi; Zhou, Jian; Yang, Yongfeng; Qi, Jinyi; Rodríguez-Villafuerte, Mercedes

    2016-01-01

    A prototype small animal positron emission tomography (PET) scanner for mouse brain imaging has been developed at UC Davis. The new scanner uses tapered detector arrays with depth of interaction (DOI) measurement. In this paper, we present an efficient system model for the tapered PET scanner using matrix factorization and a virtual scanner geometry. The factored system matrix mainly consists of two components: a sinogram blurring matrix and a geometrical matrix. The geometric matrix is based on a virtual scanner geometry. The sinogram blurring matrix is estimated by matrix factorization. We investigate the performance of different virtual scanner geometries. Both simulation study and real data experiments are performed in the fully 3D mode to study the image quality under different system models. The results indicate that the proposed matrix factorization can maintain image quality while substantially reduce the image reconstruction time and system matrix storage cost. The proposed method can be also applied to other PET scanners with DOI measurement. (paper)

  4. Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis

    Science.gov (United States)

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko

    2016-01-01

    A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal femur bone causes difficulty in setting a cementless total hip prosthesis. Therefore, total hip arthroplasty using a cemented polished tapered stem was performed via a direct lateral approach. Using a cemented polished tapered stem allowed us to deal with the femoral bone transformation and bone substance defectiveness due to exostosis and also minimized the invasiveness of the operation. PMID:27127668

  5. Wavelength tunable ultrafast fiber laser via reflective mirror with taper structure.

    Science.gov (United States)

    Fang, Li; Huang, Chuyun; Liu, Ting; Gogneau, Noelle; Bourhis, Eric; Gierak, Jacques; Oudar, Jean-Louis

    2016-12-20

    Laser sources with a controllable flexible wavelength have found widespread applications in optical fiber communication, optical sensing, and microscopy. Here, we report a tunable mode-locked fiber laser using a graphene-based saturable absorber and a tapered mirror as an end mirror in the cavity. The phase layer in the mirror is precisely etched by focused ion beam (FIB) milling technology, and the resonant wavelength of the mirror shifts correspond to the different etch depths. By scanning the tapered mirror mechanically, the center wavelength of a mode-locked fiber laser can be continuously tuned from 1562 to 1532 nm, with a pulse width in the sub-ps level and repetition rate of 27 MHz.

  6. Optical fiber refractometer based on tapered tilted-fiber Bragg grating

    Science.gov (United States)

    Wang, Tao; Liu, Tiegen; Liu, Kun; Jiang, Junfeng; Yu, Zhe; Xue, Meng

    2016-11-01

    Tilted fiber Bragg gratings (TFBGs) have been demonstrated to be accurate refractometers as they couple light from the fiber core to the cladding. In our experiment, we changed the physical structure of the TFBGs to improve the refractive index sensing ability. One way is to stretch the grating section 5 mm longer. The result showed that not only the number of the cladding mode of the TFBG decreases but also the full width half-maximum (FWHM) of the cladding modes and core mode changes. The FWHM of the cladding mode of the tapered TFBG is more than twice than that of the original. However, the refractive index sensitivity of the tapered TFBG has no obvious improvement. Another way is to etch the grating section with 20% hydrofluoric acid solution. We find that the smaller the clad diameter, the higher the refractive index sensitivity of the TFBG.

  7. Tapered Optical Fiber Sensor for Detection of pH in Microscopic Volumes

    Directory of Open Access Journals (Sweden)

    Ondřej PODRAZKÝ

    2014-05-01

    Full Text Available A compact and robust tapered optical fiber microsensor is presented for detection of pH in a range from 5.8 to 7.5 in sub-microliter volumes. The sensor is based on a pH transducer 8- hydroxypyrene-1,3,6-trisulfonic acid trisodium salt immobilized in a xerogel matrix onto the tip of a optical fiber taper with a tip diameter below 20 mm. The sol-gel method and two silicon alkoxides is used for preparing the matrix. A ratio of the fluorescence emission intensities measured at 518 nm after the excitation at 400 and 450 nm is used for evaluating the sensor response to pH. This ratiometric approach enables to reduce effects of ambient light, bleaching of the sensitive layer and geometry of the probe to the fluorescence signal and achieve the resolution of about 0.07 pH units.

  8. Graphene-Tapered ZnO Nanorods Array as a Flexible Antireflection Layer

    Directory of Open Access Journals (Sweden)

    Taeseup Song

    2015-01-01

    Full Text Available Flexible solar cells have drawn a great deal of attention due to their various advantages including deformable and wearable characteristics. In the solar cells, the antireflection layer plays an important role in the improvement in the conversion efficiency by increasing the light transmission and suppressing the Fresnel refraction. For the successful implantation of the antireflection layer into the flexible solar cells, the flexible mechanical property of the antireflection layer is also necessary. However, the study on flexible antireflection layer for the flexible solar cells or optoelectronics is still lacking. In this study, we report the graphene-tapered ZnO nanorods array as a flexible antireflection layer for the application in flexible solar cells. Flexible two-dimensional graphene sheet and the tapered morphology of ZnO nanorods enable conformal coverage on the flexible substrate with curved surface and significant improvements in antireflection properties, respectively.

  9. Some flow characteristics of conventional and tapered high-pressure-drop simulated seals

    Science.gov (United States)

    Hendricks, R. C.

    1979-01-01

    The leak rates through shaft seals with large pressure drops were simulated using gaseous hydrogen, or nitrogen flowing through an annulus with a nonrotating centerbody. The flows were choked. For concentric or eccentric position of the rotor and parallel or convergent tapered flow passages, data and analysis revealed that mass flux or leak rate can be determined from a relation whose normalizing parameters depend on the thermodynamic critical constants of the working fluid and an average flow area expressed in terms of the inlet and exit cross-sectional areas. Using these normalized relations, the flow data for parallel and three convergent, tapered, shaft-seal configurations are in good agreement. Generalization to any simple gas or gas mixtures is implied and demonstrated in part.

  10. Some flow characteristics of conventional and tapered high pressure drop simulated seals

    Science.gov (United States)

    Hendricks, R. C.

    1979-01-01

    The leak rates through shaft seals with large pressure drops were simulated using gaseous hydrogen, or nitrogen flowing through an annulus with a nonrotating centerbody. The flows were choked. For concentric or eccentric position of the rotor and parallel or convergent tapered flow passages, data and analysis revealed that mass flux or leak rate can be determined from a relation whose normalizing parameters depend on the thermodynamic critical constants of the working fluid and an average flow area expressed in terms of the inlet and exit cross-sectional areas. Using these normalized relations, the flow data for parallel and three convergent tapered shaft seal configurations are in good agreement. Generalization to any simple gas or gas mixture is implied and demonstrated.

  11. Fatigue resistance of rotary ProTaper Universal instruments after use with and without lateral pressure motion

    OpenAIRE

    Vieira, Evandro Pires; Pereira, Érika Sales Joviano; Peixoto, Isabella Faria da Cunha; Buono, Vicente Tadeu Lopes; Bahia, Maria Guiomar de Azevedo

    2016-01-01

    Aim: To evaluate the fatigue resistance of rotary ProTaper Universal instruments after multiple clinical uses with and without lateral pressure motion. Methods: Thirty sets of ProTaper Universal (PTU) instruments (Dentsply-Maillefer, Ballaigues, Switzerland), types S1, S2, F1 and F2, totaling 120 files, were analyzed and divided into three groups, as follows: Control Group (CG), with 10 sets of new instruments, which were fatigue tested until rupture to determine their fatigue resistance; Lat...

  12. Cleaning capacity promoted by motor-driven or manual instrumentation using ProTaper Universal system: Histological analysis

    OpenAIRE

    da Frota, Matheus Franco; Filho, Idomeo Bonetti; Berbert, F?bio Luiz Camargo Villela; Sponchiado, Emilio Carlos; Marques, Andr? Augusto Franco; Garcia, Lucas da Fonseca Roberti

    2013-01-01

    Aim: The aim of this study was to assess the cleaning capacity of the Protaper system using motor-driven or manual instrumentation. Materials and Methods: Ten mandibular molars were randomly separated into 2 groups (n = 5) according to the type of instrumentation performed, as follows: Group 1 - instrumentation with rotary nickel-titanium (Ni-Ti) files using ProTaper Universal System (Dentsply/Maillefer); and, Group 2 - instrumentation with Ni-Ti hand files using ProTaper Universal (Den...

  13. Endodontic Shaping Performance Using Nickel–Titanium Hand and Motor ProTaper Systems by Novice Dental Students

    OpenAIRE

    Tu, Ming-Gene; Chen, San-Yue; Huang, Heng-Li; Tsai, Chi-Cheng

    2008-01-01

    Preparing a continuous tapering conical shape and maintaining the original shape of a canal are obligatory in root canal preparation. The purpose of this study was to compare the shaping performance in simulated curved canal resin blocks of the same novice dental students using hand-prepared and engine-driven nickel–titanium (NiTi) rotary ProTaper instruments in an endodontic laboratory class. Methods: Twenty-three fourth-year dental students attending China Medical University Dental Schoo...

  14. Shear evaluation of tapered bridge girder panels with steel corrugated webs near the supports of continuous bridges

    OpenAIRE

    Zevallos, E.; Hassanein, M.F.; Real Saladrigas, Esther; Mirambell Arrizabalaga, Enrique

    2016-01-01

    Because of public construction budgets were cut over the last few years, new bridge girders with corrugated webs to reduce the construction costs have become more widely studied and used. In spite that tapered bridge girders with corrugated webs (BGCWs) are used in modern bridges, their shear strength and behaviour rarely exists in literature. Based on available literature, the web of the linearly tapered BGCWs may be divided into three typologies with different structural response to shear f...

  15. Wizard CD Plus and ProTaper Universal: analysis of apical transportation using new software

    Science.gov (United States)

    GIANNASTASIO, Daiana; da ROSA, Ricardo Abreu; PERES, Bernardo Urbanetto; BARRETO, Mirela Sangoi; DOTTO, Gustavo Nogara; KUGA, Milton Carlos; PEREIRA, Jefferson Ricardo; SÓ, Marcus Vinícius Reis

    2013-01-01

    Objective This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. Material and Methods Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature) underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection). Canals were prepared up to F2 (ProTaper) and 24.04 (Wizard CD Plus) instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. Results The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05). ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05). Conclusion Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop. PMID:24212994

  16. Wizard CD Plus and ProTaper Universal: analysis of apical transportation using new software

    Directory of Open Access Journals (Sweden)

    Daiana Giannastasio

    2013-09-01

    Full Text Available OBJECTIVE: This study has two aims: 1 to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2 to compare, with Adobe Photoshop, the ability of a new software (Regeemy in superposing and subtracting images. MATERIAL AND METHODS: Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection. Canals were prepared up to F2 (ProTaper and 24.04 (Wizard CD Plus instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. RESULTS: The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05. ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05. CONCLUSION: Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop.

  17. Comparison of Dentinal Crack Formation With Reciproc, Mtwo and ProTaper Root Canal Preparation Systems

    Directory of Open Access Journals (Sweden)

    Nazari Moghaddam

    2016-06-01

    Full Text Available Background Instrumentation with rotary instruments could potentially cause dentinal cracks possibly leading to tooth fracture. Reciproc files require a single file to finalize the root canal preparation and the effect of this procedure has not been compared with other systems. Objectives The aim of this study was to compare the incidence of dentinal micro-cracks following root canal preparations with ProTaper, Mtwo and Reciproc files. Materials and Methods In an experimental in vitro trial, 80 maxillary and mandibular first molars were selected and their crowns and distal roots were cut. The roots were then examined to remove any previous cracks and defects. An impression polyether material was used to simulate teeth periodontal ligament (PDL. The teeth were divided to four experimental groups (n = 20 and prepared using Reciproc, Mtwo and ProTaper or remained unprepared as a control group. The specimens were then sectioned horizontally on 3, 5 and 9 mm from the apex and number of micro-cracks was determined by stereomicroscope. The incidence of dentinal cracks on different systems or sections were statistically analyzed by means of the chi-square test. Results Dentinal defects on 3-mm, 5-mm and 9-mm sections from the apex were noted in 10 (5.6%; 7 (3.9% and 9 (5.0% samples of all, respectively. Following canal preparation using Reciproc, ProTaper and Mtwo systems, the defects were observed in 7 (3.9%, 12 (6.7% and 7 (3.9% the sections, respectively. No significant differences were observed regarding the defect incidence on the studied instrumentation files or sections. Conclusions Regarding the study limitations, dentinal cracks were observed in all files and distances from the apex. Although there was more crack incidence in ProTaper files, no significant differences were noted regarding the studied systems and sections from the apex.

  18. Pulse propagation in free-electron lasers with a tapered undulator

    International Nuclear Information System (INIS)

    Goldstein, J.C.; Colson, W.B.

    1981-01-01

    The one-dimensional theory of short pulse propagation in free electron lasers is extended to tapered undulator devices and is used to study the behavior of an oscillator with parameter values close to those expected in forthcoming experiments. It is found that stable laser output is possible only over a small range of optical cavity lengths. Optical pulse characteristics are presented and are found to change considerably over this range

  19. Modulation of Frequency Doubled DFB-Tapered Diode Lasers for Medical Treatment

    DEFF Research Database (Denmark)

    Christensen, Mathias; Hansen, Anders Kragh; Noordegraaf, Danny

    2017-01-01

    have demonstrated power modulation from 0.1 Hz to 10 kHz at 532 nm with a modulation depth above 97% by wavelength detuning of the laser diode. The laser diode is a 1064 nm monolithic device with a distributed feedback (DFB) laser as the master oscillator (MO), and a tapered power amplifier (PA......). The MO and PA have separate electrical contacts and the modulation is achieved with wavelength tuning by adjusting the current through the MO 40 mA....

  20. Wizard CD Plus and ProTaper Universal: analysis of apical transportation using new software.

    Science.gov (United States)

    Giannastasio, Daiana; Rosa, Ricardo Abreu da; Peres, Bernardo Urbanetto; Barreto, Mirela Sangoi; Dotto, Gustavo Nogara; Kuga, Milton Carlos; Pereira, Jefferson Ricardo; Só, Marcus Vinícius Reis

    2013-01-01

    This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature) underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection). Canals were prepared up to F2 (ProTaper) and 24.04 (Wizard CD Plus) instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05). ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05). Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop.

  1. When to Perform Antenna Measurements in a Near-Field Range or a Short Tapered Chamber

    Science.gov (United States)

    2017-03-01

    results for future antennas under test in the most cost-effective manner (man-hours, custom mount, etc.) 15. SUBJECT TERMS electromagnetic, chamber...to obtain the results for future antennas under test (AUTs) in the most cost-effective manner (man-hours, custom mounting, etc.). The NFR and...the most cost-effective manner to obtain AUT data be established for either the NFR or tapered anechoic chamber. The NFR can obtain planar

  2. Automated touch sensing in the mouse tapered beam test using Raspberry Pi.

    Science.gov (United States)

    Ardesch, Dirk Jan; Balbi, Matilde; Murphy, Timothy H

    2017-11-01

    Rodent models of neurological disease such as stroke are often characterized by motor deficits. One of the tests that are used to assess these motor deficits is the tapered beam test, which provides a sensitive measure of bilateral motor function based on foot faults (slips) made by a rodent traversing a gradually narrowing beam. However, manual frame-by-frame scoring of video recordings is necessary to obtain test results, which is time-consuming and prone to human rater bias. We present a cost-effective method for automated touch sensing in the tapered beam test. Capacitive touch sensors detect foot faults onto the beam through a layer of conductive paint, and results are processed and stored on a Raspberry Pi computer. Automated touch sensing using this method achieved high sensitivity (96.2%) as compared to 'gold standard' manual video scoring. Furthermore, it provided a reliable measure of lateralized motor deficits in mice with unilateral photothrombotic stroke: results indicated an increased number of contralesional foot faults for up to 6days after ischemia. The automated adaptation of the tapered beam test produces results immediately after each trial, without the need for labor-intensive post-hoc video scoring. It also increases objectivity of the data as it requires less experimenter involvement during analysis. Automated touch sensing may provide a useful adaptation to the existing tapered beam test in mice, while the simplicity of the hardware lends itself to potential further adaptations to related behavioral tests. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Whole-organ cell shape analysis reveals the developmental basis of ascidian notochord taper

    OpenAIRE

    Veeman, Michael T.; Smith, William C.

    2013-01-01

    Here we use in toto imaging together with computational segmentation and analysis methods to quantify the shape of every cell at multiple stages in the development of a simple organ: the notochord of the ascidian Ciona savignyi. We find that cell shape in the intercalated notochord depends strongly on anterior-posterior (AP) position, with cells in the middle of the notochord consistently wider than cells at the anterior or posterior. This morphological feature of having a tapered notochord i...

  4. Fretting and Corrosion Damage in Taper Adapter Sleeves for Ceramic Heads: A Retrieval Study.

    Science.gov (United States)

    MacDonald, Daniel W; Chen, Antonia F; Lee, Gwo-Chin; Klein, Gregg R; Mont, Michael A; Kurtz, Steven M; Cates, Harold E; Kraay, Matthew J; Rimnac, Clare M

    2017-09-01

    During revision surgery with a well-fixed stem, a titanium sleeve can be used in conjunction with a ceramic head to achieve better stress distribution across the taper surface. In vitro testing suggests that corrosion is not a concern in sleeved ceramic heads; however, little is known about the in vivo fretting corrosion of the sleeves. The purpose of this study was to investigate fretting corrosion in sleeved ceramic heads in retrieved total hip arthroplasties. Thirty-seven sleeved ceramic heads were collected during revision. The femoral heads and sleeves were implanted 0.0-3.3 years. The implants were revised predominantly for instability, infection, and loosening. Fifty percent of the retrievals were implanted during a primary surgery. Fretting corrosion was assessed using the Goldberg-Higgs semiquantitative scoring system. Mild-to-moderate fretting corrosion scores (score = 2-3) were observed in 92% of internal tapers, 19% of external tapers, and 78% of the stems. Severe fretting corrosion was observed in 1 stem trunnion that was previously retained during revision surgery and none of the retrieved sleeves. There was no difference in corrosion damage of sleeves used in primary or revision surgery. The fretting corrosion scores in this study were predominantly mild and lower than reported fretting scores of cobalt-chrome heads in metal-on-polyethylene bearings. Although intended for use in revisions, we found that the short-term in vivo corrosion behavior of the sleeves was similar in both primary and revision surgery applications. From an in vivo corrosion perspective, sleeves are a reasonable solution for restoring the stem taper during revision surgery. Copyright © 2017. Published by Elsevier Inc.

  5. Refractive index sensor based on an abrupt taper Michelson interferometer in a single-mode fiber.

    Science.gov (United States)

    Tian, Zhaobing; Yam, Scott S-H; Loock, Hans-Peter

    2008-05-15

    A simple refractive index sensor based on a Michelson interferometer in a single-mode fiber is constructed and demonstrated. The sensor consists of a single symmetrically abrupt taper region in a short piece of single-mode fiber that is terminated by approximately 500 nm thick gold coating. The sensitivity of the new sensor is similar to that of a long-period-grating-type sensor, and its ease of fabrication offers a low-cost alternative to current sensing applications.

  6. Assessment of apically extruded debris produced by the single-file ProTaper F2 technique under reciprocating movement.

    Science.gov (United States)

    De-Deus, Gustavo; Brandão, Maria Claudia; Barino, Bianca; Di Giorgi, Karina; Fidel, Rivail Antonio Sergio; Luna, Aderval Severino

    2010-09-01

    This study was designed to quantitatively evaluate the amount of dentin debris extruded from the apical foramen by comparing the conventional sequence of the ProTaper Universal nickel-titanium (NiTi) files with the single-file ProTaper F2 technique. Thirty mesial roots of lower molars were selected, and the use of different instrumentation techniques resulted in 3 groups (n=10 each). In G1, a crown-down hand-file technique was used, and in G2 conventional ProTaper Universal technique was used. In G3, ProTaper F2 file was used in a reciprocating motion. The apical finish preparation was equivalent to ISO size 25. An apparatus was used to evaluate the apically extruded debris. Statistical analysis was performed using 1-way analysis of variance and Tukey multiple comparisons. No significant difference was found in the amount of the debris extruded between the conventional sequence of the ProTaper Universal NiTi files and the single-file ProTaper F2 technique (P>.05). In contrast, the hand instrumentation group extruded significantly more debris than both NiTi groups (P<.05). The present results yielded favorable input for the F2 single-file technique in terms of apically extruded debris, inasmuch as it is the most simple and cost-effective instrumentation approach. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  7. New tapered metallic stent for unresectable malignant hilar bile duct obstruction.

    Science.gov (United States)

    Sakai, Yuji; Tsuyuguchi, Toshio; Nishikawa, Takao; Sugiyama, Harutoshi; Sasaki, Reina; Sakamoto, Dai; Watanabe, Yuto; Nakamura, Masato; Yasui, Shin; Mikata, Rintaro; Yokosuka, Osamu

    2015-10-16

    To examine the usefulness of a new tapered metallic stent (MS) in patients with unresectable malignant hilar bile duct obstruction. This new tapered MS was placed in 11 patients with Bismuth II or severer unresectable malignant hilar bile duct obstruction, as a prospective study. The subjects were six patients with bile duct carcinoma, three with gallbladder cancer, and two with metastatic bile duct obstruction. Stenosis morphology was Bismuth II: 7, IIIa: 3, and IV: 1. UMIN Clinical Trial Registry (UMIN000004758). MS placement was 100% (11/11) successful. There were no procedural accidents. The mean patency period was 208.401 d, the median survival period was 142.000 d, and the mean survival period was 193.273 d. Occlusion rate was 36.4% (4/11); the causes of occlusion were ingrowth and overgrowth in 2 patients each, 18.2%, respectively. Patients with occlusion underwent endoscopic treatment one more time and all were treatable. The tapered MS proved useful in patients with unresectable malignant hilar bile duct obstruction because it provided a long patency period, enabled re-treatment by re-intervention, and no procedural accidents occurred.

  8. Thermal and stress analyses in thermoelectric generator with tapered and rectangular pin configurations

    International Nuclear Information System (INIS)

    Yilbas, Bekir Sami; Akhtar, S.S.; Sahin, A.Z.

    2016-01-01

    Thermal stress developed in thermoelectric generators is critical for long service applications. High temperature gradients, due to a large temperature difference across the junctions, causes excessive stress levels developed in the device pins and electrodes at the interfaces. In the present study, a thermoelectric generator with horizontal pin configuration is considered and thermal stress analysis in the device is presented. Ceramic wafer is considered to resemble the high temperature plate and copper electrodes are introduced at the pin junctions to reduce the electrical resistance between the pins and the high and low temperature junction plates during the operation. Finite element code is used to simulate temperature and stress fields in the thermoelectric generator. In the simulations, convection and radiation losses from the thermoelectric pins are considered and bismuth telluride pin material with and without tapering is incorporated. It is found that von Mises stress attains high values at the interface between the hot and cold junctions and the copper electrodes. Thermal stress developed in tapered pin configuration attains lower values than that of rectangular pin cross-section. - Highlights: • Different cold junction temperatures improves thermoelectric generator performance. • von Mises stress remains high across copper electrodes and hot junction ceramics. • von Mises stress reduces along pin length towards cold junction. • Pin tapering lowers stress levels in thermoelectric generator.

  9. Tapering-induced enhancement of light extraction efficiency of nanowire deep ultraviolet LED by theoretical simulations

    KAUST Repository

    Lin, Ronghui; Galan, Sergio Valdes; Sun, Haiding; Hu, Yangrui; Alias, Mohd Sharizal; Janjua, Bilal; Ng, Tien Khee; Ooi, Boon S.; Li, Xiaohang

    2018-01-01

    A nanowire (NW) structure provides an alternative scheme for deep ultraviolet light emitting diodes (DUV-LEDs) that promises high material quality and better light extraction efficiency (LEE). In this report, we investigate the influence of the tapering angle of closely packed AlGaN NWs, which is found to exist naturally in molecular beam epitaxy (MBE) grown NW structures, on the LEE of NW DUV-LEDs. It is observed that, by having a small tapering angle, the vertical extraction is greatly enhanced for both transverse magnetic (TM) and transverse electric (TE) polarizations. Most notably, the vertical extraction of TM emission increased from 4.8% to 24.3%, which makes the LEE reasonably large to achieve high-performance DUV-LEDs. This is because the breaking of symmetry in the vertical direction changes the propagation of the light significantly to allow more coupling into radiation modes. Finally, we introduce errors to the NW positions to show the advantages of the tapered NW structures can be projected to random closely packed NW arrays. The results obtained in this paper can provide guidelines for designing efficient NW DUV-LEDs.

  10. Efficient generation of 509 nm light by sum-frequency mixing between two tapered diode lasers

    DEFF Research Database (Denmark)

    Tawfieq, Mahmoud; Jensen, Ole Bjarlin; Hansen, Anders Kragh

    2015-01-01

    We demonstrate a concept for visible laser sources based on sum-frequency generation of beam com- bined tapered diode lasers. In this specific case, a 1.7 W sum-frequency generated green laser at 509 nm is obtained, by frequency adding of 6.17 W from a 978 nm tapered diode laser with 8.06 W from...... a 1063 nm tapered diode laser, inside a periodically poled MgO doped lithium niobate crystal. This corresponds to an optical to optical conversion ef fi ciency of 12.1%. As an example of potential applica- tions, the generated nearly diffraction-limited green light is used for pumping a Ti:sapphire laser......, thus demonstrating good beam quality and power stability. The maximum output powers achieved when pumping the Ti:sapphire laser are 226 mW (CW) and 185 mW (mode-locked) at 1.7 W green pump power. The optical spectrum emitted by the mode-locked Ti:sapphire laser shows a spectral width of about 54 nm...

  11. A scanning electron microscopic study of smear layer remaining following use of Greater Taper rotary instruments

    Directory of Open Access Journals (Sweden)

    S Soumya

    2011-01-01

    Full Text Available The aim of this in vitro study was to evaluate the smear layer in the root canal following the use of Ni-Ti hand ProTaper, HERO shaper and Twisted rotary instruments. Fifteen freshly extracted single rooted human mandibular premolar teeth were selected. Crowns of all teeth were cut off at the cemento-enamel junction with a carborundum disc. The roots were then randomly divided into three groups of 5 samples each. The working length of all teeth was established by the insertion of an endodontic instrument into the canal until its tip is visible at the apical foramen and then subtracted by 0.5 mm. A sequential crown down technique was carried out in all the three groups as follows: Group-I- Specimens in this group were instrumented with ProTaper Ni-Ti hand instruments. Group-II- Specimens were instrumented with HERO shapers. Group-III - The specimens in this group were instrumented with Twisted rotary instruments. Irrigation was done with 3% NaOCl and 15% EDTA in all the three groups. Teeth were carefully split with hammer and chisel and stored in small labeled bottles containing normal saline until SEM evaluation. Results showed that when comparing ProTaper files, Twisted rotary instruments and HERO shaper instruments, HERO shaper series of rotary instruments showed maximum amount of smear layer followed by the Twisted rotary instruments. Hand instruments produced least amount of smear layer.

  12. The failures of root canal preparation with hand ProTaper.

    Science.gov (United States)

    Bătăiosu, Marilena; Diaconu, Oana; Moraru, Iren; Dăguci, C; Tuculină, Mihaela; Dăguci, Luminiţa; Gheorghiţă, Lelia

    2012-07-01

    The failures of root canal preparation are due to some anatomical deviation (canal in "C" or "S") and some technique errors. The technique errors are usually present in canal root cleansing and shaping stage and are the result of endodontic treatment objectives deviation. Our study was made on technique errors while preparing the canal roots with hand ProTaper. Our study was made "in vitro" on 84 extracted teeth (molars, premolars, incisors and canines). The canal root of these teeth were cleansed and shaped with hand ProTaper by crown-down technique and canal irrigation with NaOCl(2,5%). The dental preparation control was made by X-ray. During canal root preparation some failures were observed like: canal root overinstrumentation, zipping and stripping phenomenon, discarded and/or fractured instruments. Hand ProTaper represents a revolutionary progress of endodontic treatment, but a deviation from accepted rules of canal root instrumentation can lead to failures of endodontic treatment.

  13. Tapering-induced enhancement of light extraction efficiency of nanowire deep ultraviolet LED by theoretical simulations

    KAUST Repository

    Lin, Ronghui

    2018-04-21

    A nanowire (NW) structure provides an alternative scheme for deep ultraviolet light emitting diodes (DUV-LEDs) that promises high material quality and better light extraction efficiency (LEE). In this report, we investigate the influence of the tapering angle of closely packed AlGaN NWs, which is found to exist naturally in molecular beam epitaxy (MBE) grown NW structures, on the LEE of NW DUV-LEDs. It is observed that, by having a small tapering angle, the vertical extraction is greatly enhanced for both transverse magnetic (TM) and transverse electric (TE) polarizations. Most notably, the vertical extraction of TM emission increased from 4.8% to 24.3%, which makes the LEE reasonably large to achieve high-performance DUV-LEDs. This is because the breaking of symmetry in the vertical direction changes the propagation of the light significantly to allow more coupling into radiation modes. Finally, we introduce errors to the NW positions to show the advantages of the tapered NW structures can be projected to random closely packed NW arrays. The results obtained in this paper can provide guidelines for designing efficient NW DUV-LEDs.

  14. Influence of pitch, twist, and taper on a blade`s performance loss due to roughness

    Energy Technology Data Exchange (ETDEWEB)

    Tangler, J.L. [National Renewable Energy Laboratory, Golden, Colorado (United States)

    1997-08-01

    The purpose of this study was to determine the influence of blade geometric parameters such as pitch, twist, and taper on a blade`s sensitivity to leading edge roughness. The approach began with an evaluation of available test data of performance degradation due to roughness effects for several rotors. In addition to airfoil geometry, this evaluation suggested that a rotor`s sensitivity to roughness was also influenced by the blade geometric parameters. Parametric studies were conducted using the PROP computer code with wind-tunnel airfoil characteristics for smooth and rough surface conditions to quantify the performance loss due to roughness for tapered and twisted blades relative to a constant-chord, non-twisted blade at several blade pitch angles. The results indicate that a constant-chord, non-twisted blade pitched toward stall will have the greatest losses due to roughness. The use of twist, taper, and positive blade pitch angles all help reduce the angle-of-attack distribution along the blade for a given wind speed and the associated performance degradation due to roughness. (au)

  15. The bacterial sealing capacity of morse taper implant-abutment systems in vitro.

    Science.gov (United States)

    Ranieri, Rogerio; Ferreira, Andreia; Souza, Emmanuel; Arcoverde, Joao; Dametto, Fabio; Gade-Neto, Cicero; Seabra, Flavio; Sarmento, Carlos

    2015-05-01

    The use of Morse taper systems in dental implantology has been associated widely with a more precise adaptation between implants and their respective abutments. This may lead to an increase in the stability of the implant system and may also prevent microbial invasion through the implant-abutment interface. The aim of this study was to investigate in vitro the ability of four commercially available Morse taper system units to impede bacterial penetration through their implant-abutment interfaces. Abutments were screwed onto the implants, and the units were subsequently immersed in Streptococcus sanguinis bacterial broth (1 × 10(8) colony forming units/mL) for 48 hours. The units were examined by scanning electron microscopy (SEM) under three conditions: 1) with the implant-abutment components assembled as units to investigate for both the existence of microgaps and the presence of bacteria; 2) with the implants and abutments separated for examination of internal surfaces; and 3) with the implant-abutment components again assembled as units to measure any microgaps detected. The mean size of the microgaps in each unit was determined by measuring, under SEM, their width in four equidistant points. Microgaps were detected in all units with no significant differences in dimension (Kruskal-Wallis test, P >0.05). Within all units, the presence of bacteria was also observed. The seals provided by the interfaces of the commercially available Morse taper implant-abutment units tested were not sufficiently small to shield the implant from bacterial penetration.

  16. Mode converter based on an inverse taper for multimode silicon nanophotonic integrated circuits.

    Science.gov (United States)

    Dai, Daoxin; Mao, Mao

    2015-11-02

    An inverse taper on silicon is proposed and designed to realize an efficient mode converter available for the connection between multimode silicon nanophotonic integrated circuits and few-mode fibers. The present mode converter has a silicon-on-insulator inverse taper buried in a 3 × 3μm(2) SiN strip waveguide to deal with not only for the fundamental mode but also for the higher-order modes. The designed inverse taper enables the conversion between the six modes (i.e., TE(11), TE(21), TE(31), TE(41), TM(11), TM(12)) in a 1.4 × 0.22μm(2) multimode SOI waveguide and the six modes (like the LP(01), LP(11a), LP(11b) modes in a few-mode fiber) in a 3 × 3μm(2) SiN strip waveguide. The conversion efficiency for any desired mode is higher than 95.6% while any undesired mode excitation ratio is lower than 0.5%. This is helpful to make multimode silicon nanophotonic integrated circuits (e.g., the on-chip mode (de)multiplexers developed well) available to work together with few-mode fibers in the future.

  17. Novel Highly Sensitive Protein Sensors Based on Tapered Optical Fibres Modified with Au-Based Nanocoatings

    Directory of Open Access Journals (Sweden)

    Aitor Urrutia

    2016-01-01

    Full Text Available Novel protein sensors based on tapered optical fibres modified with Au coatings deposited using two different procedures are proposed. Au-based coatings are deposited onto a nonadiabatic tapered optical fibre using (i a novel facile method composed of layer-by-layer deposition consisting of polycation (poly(allylamine hydrochloride, PAH and negatively charged SiO2 nanoparticles (NPs followed by the deposition of the charged Au NPs and (ii the sputtering technique. The Au NPs and Au thin film surfaces are then modified with biotin in order to bind streptavidin (SV molecules and detect them. The sensing principle is based on the sensitivity of the transmission spectrum of the device to changes in the refractive index of the coatings induced by the SV binding to the biotin. Both sensors showed high sensitivity to SV, with the lowest measured concentration levels below 2.5 nM. The calculated binding constant for the biotin-SV pair was 2.2×10-11 M−1 when a tapered fibre modified with the LbL method was used, with a limit of detection (LoD of 271 pM. The sensor formed using sputtering had a binding constant of 1.01×10-10 M−1 with a LoD of 806 pM. These new structures and their simple fabrication technique could be used to develop other biosensors.

  18. An undulator with non-adiabatic tapering for the IFEL project

    CERN Document Server

    Varfolomeev, A A; Yarovoi, T V; Musumeci, P; Pellegrini, C; Rosenzweig, J

    2002-01-01

    We describe the design of a planar undulator with unusually strong tapering, for the inverse FEL experiment to be carried out in Neptune Lab. (Nucl. Instr. and Meth. A 410 (1998) 437) at UCLA. A powerful TW CO sub 2 laser will be used to accelerate electrons up to 50-60 MeV in 50 cm long undulator. A strong undulator tapering is needed because of the short Rayleigh length of the laser beam. Both the magnetic field and the undulator period are tapered to provide synchronicity of the laser beam interaction with a captured electron bunch along the whole undulator length. The most critical part of the undulator is the region near the laser focus. The main characteristics of the IFEL, such as the percentage of trapped electrons, energy of accelerated electrons and sensitivity to the laser focus transverse position, are given. The general principles of the design of this undulator construction can also be useful for high efficiency FEL amplifiers of intense laser modes.

  19. Influence of pitch, twist, and taper on a blade`s performance loss due to roughness

    Energy Technology Data Exchange (ETDEWEB)

    Tangler, J.L. [National Renewable Energy Lab., Golden, CO (United States)

    1996-12-31

    The purpose of this study was to determine the influence of blade geometric parameters such as pitch, twist, and taper on a blade`s sensitivity to leading edge roughness. The approach began with an evaluation of available test data of performance degradation due to roughness effects for several rotors. In addition to airfoil geometry, this evaluation suggested that a rotor`s sensitivity to roughness was also influenced by the blade geometric parameters. Parametric studies were conducted using the PROP computer code with wind-tunnel airfoil characteristics for smooth and rough surface conditions to quantify the performance loss due to roughness for tapered and twisted blades relative to a constant-chord, non-twisted blade at several blade pitch angles. The results indicate that a constant-chord, non-twisted blade pitched toward stall will have the greatest losses due to roughness. The use of twist, taper, and positive blade pitch angles all help reduce the angle-of-attack distribution along the blade for a given wind speed and the associated performance degradation due to roughness. 8 refs., 6 figs.

  20. Diagnostics of electron-heated solar flare models. III - Effects of tapered loop geometry and preheating

    Science.gov (United States)

    Emslie, A. G.; Li, Peng; Mariska, John T.

    1992-01-01

    A series of hydrodynamic numerical simulations of nonthermal electron-heated solar flare atmospheres and their corresponding soft X-ray Ca XIX emission-line profiles, under the conditions of tapered flare loop geometry and/or a preheated atmosphere, is presented. The degree of tapering is parameterized by the magnetic mirror ratio, while the preheated atmosphere is parameterized by the initial upper chromospheric pressure. In a tapered flare loop, it is found that the upward motion of evaporated material is faster compared with the case where the flare loop is uniform. This is due to the diverging nozzle seen by the upflowing material. In the case where the flare atmosphere is preheated and the flare geometry is uniform, the response of the atmosphere to the electron collisional heating is slow. The upward velocity of the hydrodynamic gas is reduced due not only to the large coronal column depth, but also to the increased inertia of the overlying material. It is concluded that the only possible electron-heated scenario in which the predicted Ca XIX line profiles agree with the BCS observations is when the impulsive flare starts in a preheated dense corona.

  1. Cyclic fatigue resistance of ProTaper Universal instruments when subjected to static and dynamic tests.

    Science.gov (United States)

    Lopes, Hélio P; Britto, Izabelle M O; Elias, Carlos N; Machado de Oliveira, Julio C; Neves, Mônica A S; Moreira, Edson J L; Siqueira, José F

    2010-09-01

    This study evaluated the number of cycles to fracture of ProTaper Universal S2 instruments when subjected to static and dynamic cyclic fatigue tests. ProTaper Universal S2 instruments were used until fracture in an artificial curved canal under rotational speed of 300 rpm in either a static or a dynamic test model. Afterward, the length of the fractured segments was measured and fractured surfaces and helical shafts analyzed by scanning electron microscopy (SEM). The number of cycles to fracture was significantly increased when instruments were tested in the dynamic model (Pductile mode. Plastic deformation was not observed in the helical shaft of fractured instruments. The number of cycles to fracture ProTaper Universal S2 instruments significantly increased with the use of instruments in a dynamic cyclic fatigue test compared with a static model. These findings reinforce the need for performing continuous pecking motions during rotary instrumentation of curved root canals. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  2. Design of a Tapered and Twisted Blade for the NREL Combined Experiment Rotor; TOPICAL

    International Nuclear Information System (INIS)

    Giguere, P.; Selig, M. S.

    1999-01-01

    A tapered/twisted blade was designed to operate on the Combined Experiment Rotor (CER) of the National Renewable Energy Lab., which is a stall-regulated downwind wind turbine having a rated power of 20 kilowatt. The geometry of the new blade set was optimized based on annual energy production subject to the constraints imposed on the design. These constraints were mainly related to scientific needs for fundamental research in rotor aerodynamics. A trade-off study was conducted to determine the effect of the different design constraints. Based on the results of this study, which considered nonlinear twist and taper distributions as well as the NREL S809, S814, S822 and S823 airfoils, a blade having a linear taper and a nonlinear twist distribution that uses the S809 airfoil from root to tip was selected. This blade configuration is the logical continuation of the previous constant-chord twisted and untwisted blade sets and will facilitate comparison with those earlier blades. Despite th e design constraints based on scientific needs, the new blade is more representative of commercial blades than the previous blade sets

  3. Mechanics and complications of reverse shoulder arthroplasty: morse taper failure analysis and prospective rectification

    International Nuclear Information System (INIS)

    Hoskin, HLD; Furie, E; Ganey, TM; Schlatterer, DR; Collins, W

    2017-01-01

    Since Sir John Charnley began his monumental hip arthroplasty work in 1958, clinical researchers have been incrementally improving longevity and functionality of total joint systems, although implant failure occurs on occasion. The purpose of this study is to report the fracture of the humeral tray Morse taper of a reverse total shoulder system (RTSS), which to date has not been reported with metallurgic analysis for any RTSS. There was no reported antecedent fall, motor vehicle collision, or other traumatic event prior to implant fracture in this case. Analysis was performed on the retrieved failed implant by Scanning Electron Microscopy (SEM) and Electron Dispersion Spectroscopy (EDS) in an attempt to determine the failure method, as well as to offer improvements for future implants. At the time of revision surgery all explants were retained from the left shoulder of a 61-year old male who underwent a non-complicated RTSS 4 years prior. The explants, particularly the cracked humeral tray, were processed as required for SEM and EDS. Analysis was performed on the failure sites in order to determine the chemical composition of the different parts of the implant, discover the chemical composition of the filler metal used during the electron beam welding process, and to detect any foreign elements that could suggest corrosion or other evidence of failure etiology. Gross visual inspection of all explants revealed that implant failure was a result of dissociation of the taper from the humeral tray at the weld, leaving the Morse taper embedded in the humeral stem while the tray floated freely in the patient’s shoulder. SEM further confirmed the jagged edges noted grossly at the weld fracture site, both suggesting failure due to torsional forces. EDS detected elevated levels of carbon and oxygen at the fracture site on the taper only and not on the humeral tray. In order to determine the origin of the high levels of C and O, it was considered that in titanium alloys, C

  4. Optimizing treatment with tumour necrosis factor inhibitors in rheumatoid arthritis—a proof of principle and exploratory trial: is dose tapering practical in good responders?

    Science.gov (United States)

    Lorente-Cánovas, Beatriz; Doré, Caroline J; Bosworth, Ailsa; Ma, Margaret H; Galloway, James B; Cope, Andrew P; Pande, Ira; Walker, David; Scott, David L

    2017-01-01

    Abstract Objectives RA patients receiving TNF inhibitors (TNFi) usually maintain their initial doses. The aim of the Optimizing Treatment with Tumour Necrosis Factor Inhibitors in Rheumatoid Arthritis trial was to evaluate whether tapering TNFi doses causes loss of clinical response. Methods We enrolled RA patients receiving etanercept or adalimumab and a DMARD with DAS28 under 3.2 for over 3 months. Initially (months 0–6) patients were randomized to control (constant TNFi) or two experimental groups (tapering TNFi by 33 or 66%). Subsequently (months 6–12) control subjects were randomized to taper TNFi by 33 or 66%. Disease flares (DAS28 increasing ⩾0.6 with at least one additional swollen joint) were the primary outcome. Results Two hundred and forty-four patients were screened, 103 randomized and 97 treated. In months 0–6 there were 8/50 (16%) flares in controls, 3/26 (12%) with 33% tapering and 6/21 (29%) with 66% tapering. Multivariate Cox analysis showed time to flare was unchanged with 33% tapering but was reduced with 66% tapering compared with controls (adjusted hazard ratio 2.81, 95% CI: 0.99, 7.94; P = 0.051). Analysing all tapered patients after controls were re-randomized (months 6–12) showed differences between groups: there were 6/48 (13%) flares with 33% tapering and 14/39 (36%) with 66% tapering. Multivariate Cox analysis showed 66% tapering reduced time to flare (adjusted hazard ratio 3.47, 95% CI: 1.26, 9.58; P = 0.016). Conclusion Tapering TNFi by 33% has no impact on disease flares and appears practical in patients in sustained remission and low disease activity states. Trail registration EudraCT, https://www.clinicaltrialsregister.eu, 2010-020738-24; ISRCTN registry, https://www.isrctn.com, 28955701 PMID:28968858

  5. Optimizing treatment with tumour necrosis factor inhibitors in rheumatoid arthritis-a proof of principle and exploratory trial: is dose tapering practical in good responders?

    Science.gov (United States)

    Ibrahim, Fowzia; Lorente-Cánovas, Beatriz; Doré, Caroline J; Bosworth, Ailsa; Ma, Margaret H; Galloway, James B; Cope, Andrew P; Pande, Ira; Walker, David; Scott, David L

    2017-11-01

    RA patients receiving TNF inhibitors (TNFi) usually maintain their initial doses. The aim of the Optimizing Treatment with Tumour Necrosis Factor Inhibitors in Rheumatoid Arthritis trial was to evaluate whether tapering TNFi doses causes loss of clinical response. We enrolled RA patients receiving etanercept or adalimumab and a DMARD with DAS28 under 3.2 for over 3 months. Initially (months 0-6) patients were randomized to control (constant TNFi) or two experimental groups (tapering TNFi by 33 or 66%). Subsequently (months 6-12) control subjects were randomized to taper TNFi by 33 or 66%. Disease flares (DAS28 increasing ⩾0.6 with at least one additional swollen joint) were the primary outcome. Two hundred and forty-four patients were screened, 103 randomized and 97 treated. In months 0-6 there were 8/50 (16%) flares in controls, 3/26 (12%) with 33% tapering and 6/21 (29%) with 66% tapering. Multivariate Cox analysis showed time to flare was unchanged with 33% tapering but was reduced with 66% tapering compared with controls (adjusted hazard ratio 2.81, 95% CI: 0.99, 7.94; P = 0.051). Analysing all tapered patients after controls were re-randomized (months 6-12) showed differences between groups: there were 6/48 (13%) flares with 33% tapering and 14/39 (36%) with 66% tapering. Multivariate Cox analysis showed 66% tapering reduced time to flare (adjusted hazard ratio 3.47, 95% CI: 1.26, 9.58; P = 0.016). Tapering TNFi by 33% has no impact on disease flares and appears practical in patients in sustained remission and low disease activity states. EudraCT, https://www.clinicaltrialsregister.eu, 2010-020738-24; ISRCTN registry, https://www.isrctn.com, 28955701. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology.

  6. Evaluation of the resistance to cyclic fatigue among ProTaper Next, ProTaper Universal, and Vortex Blue rotary instruments.

    Science.gov (United States)

    Nguyen, Harrison H; Fong, Hanson; Paranjpe, Avina; Flake, Natasha M; Johnson, James D; Peters, Ove A

    2014-08-01

    The purpose of this study was to compare the fracture resistance to cyclic fatigue of ProTaper Next (PTN; Dentsply Tulsa Dental Specialties, Tulsa, OK), ProTaper Universal (PTU, Dentsply Tulsa Dental Specialties), and Vortex Blue (VB, Dentsply Tulsa Dental Specialties) rotary instruments. Twenty instruments each of PTN X1-X5, PTU S1-F5, and VB 20/04-50/04 were rotated until fracture in a simulated canal of 90° and a 5-mm radius using a custom-made testing platform. The number of cycles to fracture (NCF) was calculated. Weibull analysis was used to predict the maximum number of cycles when 99% of the instrument samples survive. VB 20/04-30/04 had significantly higher NCF than PTU S1-F5 and PTN X1-X5. VB 35/04-45/04 had significantly higher NCF than PTU S2-F5 and PTN X2-X5. PTN X1 had higher NCF than PTU S1-F5. PTN X2 had higher NCF than PTU F2-F5. The Weibull distribution predicted the highest number of cycles at which 99% of instruments survive to be 766 cycles for VB 25/04 and the lowest to be 50 cycles for PTU F2. Under the limitations of this study, VB 20/04-45/04 were more resistant to cyclic fatigue than PTN X2-X5 and PTU S2-F5. PTN X1 and X2 were more resistant to cyclic fatigue than PTU F2-F5. The Weibull distribution appears to be a feasible and potentially clinically relevant model to predict resistance to cyclic fatigue. Copyright © 2014 American Association of Endodontists. All rights reserved.

  7. Influence of NiTi alloy on the root canal shaping capabilities of the ProTaper Universal and ProTaper Gold rotary instrument systems

    Directory of Open Access Journals (Sweden)

    Jussaro Alves DUQUE

    Full Text Available Abstract Objective This study aimed to evaluate the influence of the NiTi wire in Conventional NiTi (ProTaper Universal PTU and Controlled Memory NiTi (ProTaper Gold PTG instrument systems on the quality of root canal preparation. Material and Methods Twelve mandibular molars with separate mesial canals were scanned using a high-definition microcomputed tomography system. The PTU and PTG instruments were used to shape twelve mesial canals each. The canals were scanned after preparation with F2 and F3 instruments of the PTU and PTG systems. The analyzed parameters included the remaining dentin thickness at the apical and cervical levels, root canal volume and untouched canal walls. Data was analyzed for statistical significance by the Friedman and Dunn’s tests. For the comparison of data between groups, the Mann-Whitney test was used. Results In the pre-operative analysis, there were no statistically significant differences between the groups in terms of the area and volume of root canals (P>.05. There was also no statistically significant difference between the systems with respect to root canal volume after use of the F2 and F3 instruments. There was no statistical difference in the dentin thickness at the first apical level between, before and after instrumentation for both systems. At the 3 cervical levels, the PTG maintained centralization of the preparation on the transition between the F2 and F3 instruments, which did not occur with the PTU. Conclusion The Conventional NiTi (PTU and Controlled Memory NiTi (PTG instruments displayed comparable capabilities for shaping the straight mesial root canals of mandibular molars, although the PTG was better than the PTU at maintaining the centralization of the shape in the cervical portion.

  8. Influence of NiTi alloy on the root canal shaping capabilities of the ProTaper Universal and ProTaper Gold rotary instrument systems

    Science.gov (United States)

    DUQUE, Jussaro Alves; VIVAN, Rodrigo Ricci; CAVENAGO, Bruno Cavalini; AMOROSO-SILVA, Pablo Andrés; BERNARDES, Ricardo Affonso; de VASCONCELOS, Bruno Carvalho; DUARTE, Marco Antonio Hungaro

    2017-01-01

    Abstract Objective This study aimed to evaluate the influence of the NiTi wire in Conventional NiTi (ProTaper Universal PTU) and Controlled Memory NiTi (ProTaper Gold PTG) instrument systems on the quality of root canal preparation. Material and Methods Twelve mandibular molars with separate mesial canals were scanned using a high-definition microcomputed tomography system. The PTU and PTG instruments were used to shape twelve mesial canals each. The canals were scanned after preparation with F2 and F3 instruments of the PTU and PTG systems. The analyzed parameters included the remaining dentin thickness at the apical and cervical levels, root canal volume and untouched canal walls. Data was analyzed for statistical significance by the Friedman and Dunn’s tests. For the comparison of data between groups, the Mann-Whitney test was used. Results In the pre-operative analysis, there were no statistically significant differences between the groups in terms of the area and volume of root canals (P>.05). There was also no statistically significant difference between the systems with respect to root canal volume after use of the F2 and F3 instruments. There was no statistical difference in the dentin thickness at the first apical level between, before and after instrumentation for both systems. At the 3 cervical levels, the PTG maintained centralization of the preparation on the transition between the F2 and F3 instruments, which did not occur with the PTU. Conclusion The Conventional NiTi (PTU) and Controlled Memory NiTi (PTG) instruments displayed comparable capabilities for shaping the straight mesial root canals of mandibular molars, although the PTG was better than the PTU at maintaining the centralization of the shape in the cervical portion. PMID:28198973

  9. Double-pass tapered amplifier diode laser with an output power of 1 W for an injection power of only 200 μW.

    Science.gov (United States)

    Bolpasi, V; von Klitzing, W

    2010-11-01

    A 1 W tapered amplifier requiring only 200 μW of injection power at 780 nm is presented in this paper. This is achieved by injecting the seeding light into the amplifier from its tapered side and feeding the amplified light back into the small side. The amplified spontaneous emission of the tapered amplifier is suppressed by 75 dB. The double-passed tapered laser, presented here, is extremely stable and reliable. The output beam remains well coupled to the optical fiber for a timescale of months, whereas the injection of the seed light did not require realignment for over a year of daily operation.

  10. An evaluation of factors influencing pore pressure in accretionary complexes: Implications for taper angle and wedge mechanics

    Science.gov (United States)

    Saffer, D.M.; Bekins, B.A.

    2006-01-01

    At many subduction zones, accretionary complexes form as sediment is off-scraped from the subducting plate. Mechanical models that treat accretionary complexes as critically tapered wedges of sediment demonstrate that pore pressure controls their taper angle by modifying basal and internal shear strength. Here, we combine a numerical model of groundwater flow with critical taper theory to quantify the effects of sediment and de??collement permeability, sediment thickness, sediment partitioning between accretion and underthrusting, and plate convergence rate on steady state pore pressure. Our results show that pore pressure in accretionary wedges can be viewed as a dynamically maintained response to factors which drive pore pressure (source terms) and those that limit flow (permeability and drainage path length). We find that sediment permeability and incoming sediment thickness are the most important factors, whereas fault permeability and the partitioning of sediment have a small effect. For our base case model scenario, as sediment permeability is increased, pore pressure decreases from near-lithostatic to hydrostatic values and allows stable taper angles to increase from ??? 2.5?? to 8??-12.5??. With increased sediment thickness in our models (from 100 to 8000 m), increased pore pressure drives a decrease in stable taper angle from 8.4??-12.5?? to 15?? to <4??) with increased sediment thickness (from <1 to 7 km). One key implication is that hydrologic properties may strongly influence the strength of the crust in a wide range of geologic settings. Copyright 2006 by the American Geophysical Union.

  11. ProTaper rotary instrument fracture during root canal preparation: a comparison between rotary and hybrid techniques.

    Science.gov (United States)

    Farid, Huma; Khan, Farhan Raza; Rahman, Munawar

    2013-03-01

    This study aimed to compare the frequency of ProTaper rotary instrument fracture with rotary (conventional) and hybrid (rotary and hand files) canal preparation techniques. Secondary objectives were to determine whether there was an association of ProTaper file fracture with the canal curvature and to compare the mean time required for canal preparation in the two techniques. An in vitro experiment was conducted on 216 buccal canals of extracted maxillary and mandibular first molars. After creating an access cavity and a glide path for each canal, a periapical radiograph was taken and the canal curvature was measured with Schneider's technique. The canals were then randomly divided into Group A (rotary technique) and Group B (hybrid technique). The length of ProTaper files were measured before and after each canal preparation. Time taken for each canal preparation was recorded. A total of seven ProTaper files fractured in Group A (P=0.014) in canals with a curvature >25 degrees (PProTaper rotary files, although time consuming, was safer in canals having a curvature greater than 25 degrees.

  12. Fitting and Calibrating a Multilevel Mixed-Effects Stem Taper Model for Maritime Pine in NW Spain

    Science.gov (United States)

    Arias-Rodil, Manuel; Castedo-Dorado, Fernando; Cámara-Obregón, Asunción; Diéguez-Aranda, Ulises

    2015-01-01

    Stem taper data are usually hierarchical (several measurements per tree, and several trees per plot), making application of a multilevel mixed-effects modelling approach essential. However, correlation between trees in the same plot/stand has often been ignored in previous studies. Fitting and calibration of a variable-exponent stem taper function were conducted using data from 420 trees felled in even-aged maritime pine (Pinus pinaster Ait.) stands in NW Spain. In the fitting step, the tree level explained much more variability than the plot level, and therefore calibration at plot level was omitted. Several stem heights were evaluated for measurement of the additional diameter needed for calibration at tree level. Calibration with an additional diameter measured at between 40 and 60% of total tree height showed the greatest improvement in volume and diameter predictions. If additional diameter measurement is not available, the fixed-effects model fitted by the ordinary least squares technique should be used. Finally, we also evaluated how the expansion of parameters with random effects affects the stem taper prediction, as we consider this a key question when applying the mixed-effects modelling approach to taper equations. The results showed that correlation between random effects should be taken into account when assessing the influence of random effects in stem taper prediction. PMID:26630156

  13. Theoretical calculations and experimental verification for the pumping effect caused by the dynamic micro-tapered angle

    Science.gov (United States)

    Cai, Yufei; Zhang, Jianhui; Zhu, Chunling; Huang, Jun; Jiang, Feng

    2016-05-01

    The atomizer with micro cone apertures has advantages of ultra-fine atomized droplets, low power consumption and low temperature rise. The current research of this kind of atomizer mainly focuses on the performance and its application while there is less research of the principle of the atomization. Under the analysis of the dispenser and its micro-tapered aperture's deformation, the volume changes during the deformation and vibration of the micro-tapered aperture on the dispenser are calculated by coordinate transformation. Based on the characters of the flow resistance in a cone aperture, it is found that the dynamic cone angle results from periodical changes of the volume of the micro-tapered aperture of the atomizer and this change drives one-way flows. Besides, an experimental atomization platform is established to measure the atomization rates with different resonance frequencies of the cone aperture atomizer. The atomization performances of cone aperture and straight aperture atomizers are also measured. The experimental results show the existence of the pumping effect of the dynamic tapered angle. This effect is usually observed in industries that require low dispersion and micro- and nanoscale grain sizes, such as during production of high-pressure nozzles and inhalation therapy. Strategies to minimize the pumping effect of the dynamic cone angle or improve future designs are important concerns. This research proposes that dynamic micro-tapered angle is an important cause of atomization of the atomizer with micro cone apertures.

  14. Opioid tapering in patients with prescription opioid use disorder: A retrospective study.

    Science.gov (United States)

    Zhou, Kehua; Jia, Peng; Bhargava, Swati; Zhang, Yong; Reza, Taslima; Peng, Yuan Bo; Wang, Gary G

    2017-10-01

    Opioid use disorder (OUD) refers to a maladaptive pattern of opioid use leading to clinically significant impairment or distress. OUD causes, and vice versa, misuses and abuse of opioid medications. Clinicians face daily challenges to treat patients with prescription opioid use disorder. An evidence-based management for people who are already addicted to opioids has been identified as the national priority in the US; however, options are limited in clinical practices. In this study, we aimed to explore the success rate and important adjuvant medications in the medication assisted treatment with temporary use of methadone for opioid discontinuation in patients with prescription OUD. This is a retrospective chart review performed at a private physician office for physical medicine and rehabilitation. We reviewed all medical records dated between December 1st, 2011 and August 30th, 2016. The initial evaluation of the included patients (N=140) was completed between December 1st, 2011 and December 31st, 2014. They all have concumittant prescription OUD and chronic non-cancer pain. The patients (87 female and 53 male) were 46.7±12.7 years old, and had a history of opioid use of 7.7±6.1 years. All patients received the comprehensive opioid taper treatments (including interventional pain management techniques, psychotherapy, acupuncture, physical modalities and exercises, and adjuvant medications) on top of the medication assisted treatment using methadone (transient use). Opioid tapering was considered successful when no opioid medication was used in the last patient visit. The 140 patients had pain of 9.6±8.4 years with 8/10 intensity before treatment which decreased after treatment in all comparisons (pOUD. For patients with OUD, indefinite opioid maintenance treatment may not be necessary. Considering the ethical values of autonomy, nonmaleficence, and beneficence, clinicians should provide patients with OUD the option of opioid tapering. Copyright © 2017

  15. Obtaining high degree of circular polarization at X-ray FELs via a reverse undulator taper

    Energy Technology Data Exchange (ETDEWEB)

    Schneidmiller, E.A.; Yurkov, M.V.

    2013-08-15

    Baseline design of a typical X-ray FEL undulator assumes a planar configuration which results in a linear polarization of the FEL radiation. However, many experiments at X-ray FEL user facilities would profit from using a circularly polarized radiation. As a cheap upgrade one can consider an installation of a short helical (or cross-planar) afterburner, but then one should have an efficient method to suppress powerful linearly polarized background from the main undulator. In this paper we propose a new method for such a suppression: an application of the reverse taper in the main undulator. We discover that in a certain range of the taper strength, the density modulation (bunching) at saturation is practically the same as in the case of non-tapered undulator while the power of linearly polarized radiation is suppressed by orders of magnitude. Then strongly modulated electron beam radiates at full power in the afterburner. Considering SASE3 undulator of the European XFEL as a practical example, we demonstrate that soft X-ray radiation pulses with peak power in excess of 100 GW and an ultimately high degree of circular polarization can be produced. The proposed method is rather universal, i.e. it can be used at SASE FELs and seeded (self-seeded) FELs, with any wavelength of interest, in a wide range of electron beam parameters, and with any repetition rate. It can be used at different X-ray FEL facilities, in particular at LCLS after installation of the helical afterburner in the near future.

  16. Coherent combining of high brightness tapered lasers in master oscillator power amplifier configuration

    Science.gov (United States)

    Albrodt, P.; Hanna, M.; Moron, F.; Decker, J.; Winterfeldt, M.; Blume, G.; Erbert, G.; Crump, P.; Georges, P.; Lucas-Leclin, G.

    2018-02-01

    Improved diode laser beam combining techniques are in strong demand for applications in material processing. Coherent beam combining (CBC) is the only combining approach that has the potential to maintain or even improve all laser properties, and thus has high potential for future systems. As part of our ongoing studies into CBC of diode lasers, we present recent progress in the coherent superposition of high-power single-pass tapered laser amplifiers. The amplifiers are seeded by a DFB laser at λ = 976 nm, where the seed is injected into a laterally single-mode ridge-waveguide input section. The phase pistons on each beam are actively controlled by varying the current in the ridge section of each amplifier, using a sequential hill-climbing algorithm, resulting in a combined beam with power fluctuations of below 1%. The currents into the tapered sections of the amplifiers are separately controlled, and remain constant. In contrast to our previous studies, we favour a limited number of individual high-power amplifiers, in order to preserve a high extracted power per emitter in a simple, low-loss coupling arrangement. Specifically, a multi-arm interferometer architecture with only three devices is used, constructed using 6 mm-long tapered amplifiers, mounted junction up on C-mounts, to allow separate contact to single mode and amplifier sections. A maximum coherently combined power of 12.9 W is demonstrated in a nearly diffraction-limited beam, corresponding to a 65% combining efficiency, with power mainly limited by the intrinsic beam quality of the amplifiers. Further increased combined power is currently sought.

  17. Configuring the Mesh Size, Side Taper and Wing Depth of Penaeid Trawls to Reduce Environmental Impacts

    Science.gov (United States)

    Broadhurst, Matt K.; Sterling, David J.; Millar, Russell B.

    2014-01-01

    The effects of reducing mesh size while concomitantly varying the side taper and wing depth of a generic penaeid-trawl body were investigated to improve engineering performance and minimize bycatch. Five trawl bodies (with the same codends) were tested across various environmental (e.g. depth and current) and biological (e.g. species and sizes) conditions. The first trawl body comprised 41-mm mesh and represented conventional designs (termed the ‘41 long deep-wing'), while the remaining trawl bodies were made from 32-mm mesh and differed only in their side tapers, and therefore length (i.e. 1N3B or ‘long’ and ∼28o to the tow direction vs 1N5B or ‘short’ and ∼35o) and wing depths (‘deep’–97 T vs ‘shallow’–60 T). There were incremental drag reductions (and therefore fuel savings – by up to 18 and 12% per h and ha trawled) associated with reducing twine area via either modification, and subsequently minimizing otter-board area in attempts to standardize spread. Side taper and wing depth had interactive and varied effects on species selectivity, but compared to the conventional 41 long deep-wing trawl, the 32 short shallow-wing trawl (i.e. the least twine area) reduced the total bycatch by 57% (attributed to more fish swimming forward and escaping). In most cases, all small-meshed trawls also caught more smaller school prawns Metapenaeus macleayi but to decrease this effect it should be possible to increase mesh size slightly, while still maintaining the above engineering benefits and species selectivity. The results support precisely optimizing mesh size as a precursor to any other anterior penaeid-trawl modifications designed to improve environmental performance. PMID:24911786

  18. Wear of K3 and ProTaper files after simulated clinical use in curved canals

    Directory of Open Access Journals (Sweden)

    Patrícia de Almeida Rodrigues Silva e Souza

    2009-01-01

    Full Text Available Objective: To assess wear, after simulated clinical use of K3 (SybronEndo, Orange, CA, EUA and ProTaper files (Dentsply-Maillefer, Tulsa, Oklahoma, EUA in 46 mesiovestibular roots of human maxillary first molars, recently extracted and with mean angulation of 40°.Methods: The teeth were divided as follows: a K3 (SybronEndo, Orange, CA, EUA (with radial bands and b ProTaper (Dentsply-Maillefer, Tulsa, Oklahoma, EUA (without radial bands. The files were assessed by scanning electronic microscopy before first use to visualize fabrication defects, and after 7 and 13 cycles of debridement in the canals. Debridement with files K3 (SybronEndo, Orange, CA, EUA and ProTaper (Dentsply-Maillefer, Tulsa, Oklahoma, EUA was performed in accordance with the manufacturers’ recommendations. The criteria for wear assessment were: defects (stretching, shortening/spiral inversion, presence of craters, oblique cracks and fracture. After assessment by SEM and before they were used, metal barbs on the crest of the spirals and oblique scratches due to the machining process were found in all the files.Results: In the K3 system (SybronEndo, Orange, CA, USA, after being used seven times, all the instruments showed cutting angle defects,and 25/08 and 25/10 had oblique cracks in the body of the active part leading to ductile fracture after being used for the eighth time. In the ProTaper system (Dentsply-Maillefer, Tulsa, Oklahoma, USA, after being used seven times, in addition to cutting angle defects, the files also presented cracks, and ruptile fracture occurred in F3 during use for the thirteenth time. At the end of preparation, craters were seen along the active part of the files.Conclusion: In the final analysis, it was seen that the system are equivalent with regard to the defects found, irrespective of the active part design,being proportional to the number of cycles of use, and these defects could act as points of greater fragility, favoring fracture.

  19. A Review of Multimode Interference in Tapered Optical Fibers and Related Applications

    Science.gov (United States)

    Wang, Pengfei; Zhao, Haiyan; Wang, Xianfan; Brambilla, Gilberto

    2018-01-01

    In recent years, tapered optical fibers (TOFs) have attracted increasing interest and developed into a range of devices used in many practical applications ranging from optical communication, sensing to optical manipulation and high-Q resonators. Compared with conventional optical fibers, TOFs possess a range of unique features, such as large evanescent field, strong optical confinement, mechanical flexibility and compactness. In this review, we critically summarize the multimode interference in TOFs and some of its applications with a focus on our research project undertaken at the Optoelectronics Research Centre of the University of Southampton in the United Kingdom. PMID:29538333

  20. Comparison of SHG Power Modulation by Wavelength Detuning of DFB- and DBR-Tapered Laser Diodes

    DEFF Research Database (Denmark)

    Christensen, Mathias; Hansen, Anders Kragh; Noordegraaf, Danny

    2016-01-01

    of the response of the second harmonic light to perturbations of the infrared laser diode and compare how the response differs for DFB- and DBR-Tapered laser diodes. We show that the visible light can be modulated from CW to kHz with modulation depths above 90% by wavelength detuning the laser diode.......Pulsed visible lasers are used for a number of applications such as laser displays and medical treatments. Generating this visible light by direct frequency doubling of high power diode lasers opens new possibilities on how the power modulation can be performed. We present an investigation...

  1. The failures of root canal preparation with hand ProTaper

    OpenAIRE

    Bătăiosu, Marilena; Diaconu, Oana; Moraru, Iren; Dăguci, C.; Ţuculină, Mihaela; Dăguci, Luminiţa; Gheorghiţă, Lelia

    2012-01-01

    The failures of root canal preparation are due to some anatomical deviation (canal in “C” or “S”) and some technique errors. The technique errors are usually present in canal root cleansing and shaping stage and are the result of endodontic treatment objectives deviation. Objectives: Our study was made on technique errors while preparing the canal roots with hand ProTaper. Methodology: Our study was made “in vitro” on 84 extracted teeth (molars, premolars, incisors and canines). The canal roo...

  2. Stability of the mode-locking regime in tapered quantum-dot lasers

    Science.gov (United States)

    Bardella, P.; Drzewietzki, L.; Rossetti, M.; Weber, C.; Breuer, S.

    2018-02-01

    We study numerically and experimentally the role of the injection current and reverse bias voltage on the pulse stability of tapered, passively mode-locked, Quantum Dot (QD) lasers. By using a multi-section delayed differential equation and introducing in the model the QD inhomogenous broadening, we are able to predict the onset of leading and trailing edge instabilities in the emitted pulse trains and to identify specific trends of stability in dependence on the laser biasing conditions. The numerical results are confirmed experimentally trough amplitude and timing stability analysis of the pulses.

  3. Plasma Etching of Tapered Features in Silicon for MEMS and Wafer Level Packaging Applications

    International Nuclear Information System (INIS)

    Ngo, H-D; Hiess, Andre; Seidemann, Volker; Studzinski, Daniel; Lange, Martin; Leib, Juergen; Shariff, Dzafir; Ashraf, Huma; Steel, Mike; Atabo, Lilian; Reast, Jon

    2006-01-01

    This paper is a brief report of plasma etching as applied to pattern transfer in silicon. It will focus more on concept overview and strategies for etching of tapered features of interest for MEMS and Wafer Level Packaging (WLP). The basis of plasma etching, the dry etching technique, is explained and plasma configurations are described elsewhere. An important feature of plasma etching is the possibility to achieve etch anisotropy. The plasma etch process is extremely sensitive to many variables such as mask material, mask openings and more important the plasma parameters

  4. Determination of Periodic Solution for Tapered Beams with Modified Iteration Perturbation Method

    Directory of Open Access Journals (Sweden)

    Mohammad Mehdi Mashinchi Joubari

    2015-01-01

    Full Text Available In this paper, we implemented the Modified Iteration Perturbation Method (MIPM for approximating the periodic behavior of a tapered beam. This problem is formulated as a nonlinear ordinary differential equation with linear and nonlinear terms. The solution is quickly convergent and does not need to complicated calculations. Comparing the results of the MIPM with the exact solution shows that this method is effective and convenient. Also, it is predicated that MIPM can be potentially used in the analysis of strongly nonlinear oscillation problems accurately.

  5. Simulation of transmission of slow highly charged ions through insulating tapered macro-capillaries

    International Nuclear Information System (INIS)

    Schweigler, T.; Lemell, C.; Burgdoerfer, J.

    2011-01-01

    The field of charged-particle transmission through insulating nanocapillaries has expanded its scope within the last few years. Originally motivated by research on elementary ion-insulator interactions recent work has shifted the focus on the development of tools for ion-beam shaping and guiding. The design of tapered macrocapillaries has attracted growing interest and has found first applications in directing ions to targeted regions of biological cells for microsurgery. Due to the large dimensions of these capillaries, simulation of such systems faces considerable difficulties which we address in this paper. A first proof-of-principle simulation is presented.

  6. Blood flow of Jeffrey fluid in a catherized tapered artery with the suspension of nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Ellahi, R., E-mail: rellahi@engr.ucr.edu [Department of Mechanical Engineering, University of California Riverside (United States); Department of Mathematics and Statistics, FBAS, IIU, Islamabad (Pakistan); Rahman, S.U. [Department of Mathematics and Statistics, FBAS, IIU, Islamabad (Pakistan); Nadeem, S. [Department of Mathematics, Quaid-i-Azam University Islamabad (Pakistan)

    2014-08-14

    Current letter deals with the mathematical models of Jeffrey fluid via nanoparticles in the tapered stenosed atherosclerotic arteries. The convection effects of heat transfer with catheter are also taken into account. The nonlinear coupled equations of nanofluid model are simplified under mild stenosis. The solutions for concentration and temperature are found by using homotopy perturbation method, whereas for velocity profile the exact solution is calculated. Moreover, the expressions for flow impedance and pressure rise are computed and discussed through graphs for different physical quantities of interest. The streamlines have also been presented to discuss the trapping bolus discipline.

  7. Mechanical analysis of a $\\beta=0.09 $ 162.5MHz taper HWR cavity

    OpenAIRE

    Fan, Peiliang; Zhu, Feng; Zhong, Hutianxiang; Quan, Shengwen; Liu, Kexin

    2015-01-01

    One superconducting taper-type half-wave resonator (HWR) with frequency of 162.5MHz, \\b{eta} of 0.09 has been developed at Peking University, which is used to accelerate high current proton ($\\sim$ 100mA) and $D^{+}$($\\sim$ 50mA). The radio frequency (RF) design of the cavity has been accomplished. Herein, we present the mechanical analysis of the cavity which is also an important aspect in superconducting cavity design. The frequency shift caused by bath helium pressure and Lorenz force, and...

  8. A Review of Multimode Interference in Tapered Optical Fibers and Related Applications

    Directory of Open Access Journals (Sweden)

    Pengfei Wang

    2018-03-01

    Full Text Available In recent years, tapered optical fibers (TOFs have attracted increasing interest and developed into a range of devices used in many practical applications ranging from optical communication, sensing to optical manipulation and high-Q resonators. Compared with conventional optical fibers, TOFs possess a range of unique features, such as large evanescent field, strong optical confinement, mechanical flexibility and compactness. In this review, we critically summarize the multimode interference in TOFs and some of its applications with a focus on our research project undertaken at the Optoelectronics Research Centre of the University of Southampton in the United Kingdom.

  9. A Review of Multimode Interference in Tapered Optical Fibers and Related Applications.

    Science.gov (United States)

    Wang, Pengfei; Zhao, Haiyan; Wang, Xianfan; Farrell, Gerald; Brambilla, Gilberto

    2018-03-14

    In recent years, tapered optical fibers (TOFs) have attracted increasing interest and developed into a range of devices used in many practical applications ranging from optical communication, sensing to optical manipulation and high-Q resonators. Compared with conventional optical fibers, TOFs possess a range of unique features, such as large evanescent field, strong optical confinement, mechanical flexibility and compactness. In this review, we critically summarize the multimode interference in TOFs and some of its applications with a focus on our research project undertaken at the Optoelectronics Research Centre of the University of Southampton in the United Kingdom.

  10. Tapered silicon core fibers with nano-spikes for optical coupling via spliced silica fibers

    OpenAIRE

    Ren, Haonan; Aktas, Ozan; Franz, Yohann; Runge, Antoine; Hawkins, Thomas A.; Ballato, John; Gibson, Ursula; Peacock, Anna

    2017-01-01

    Abstract: Reported here is the fabrication of tapered silicon core fibers possessing a nanospike input that facilitates their seamless splicing to conventional single mode fibers. A proofof-concept 30 µm cladding diameter fiber-based device is demonstrated with nano-spike coupling and propagation losses below 4 dB and 2 dB/cm, respectively. Finite-elementmethod-based simulations show that the nano-spike coupling losses could be reduced to below 1 dB by decreasing the cladding diameters down t...

  11. High energy supercontinuum sources using tapered photonic crystal fibers for multispectral photoacoustic microscopy

    DEFF Research Database (Denmark)

    Bondu, Magalie; Brooks, Christopher; Jakobsen, Christian

    2016-01-01

    We demonstrate a record bandwidth high energy supercontinuum source suitable for multispectral photoacoustic microscopy. The source has more than 150  nJ/10  nm150  nJ/10  nm bandwidth over a spectral range of 500 to 1600 nm. This performance is achieved using a carefully designed fiber taper...... with large-core input for improved power handling and small-core output that provides the desired spectral range of the supercontinuum source....

  12. Near-unity efficiency, single-photon sources based on tapered photonic nanowires

    DEFF Research Database (Denmark)

    Bleuse, Joël; Munsch, Mathieu; Claudon, Julien

    2012-01-01

    Single-photon emission from excitons in InAs Quantum Dots (QD) embedded in GaAs Tapered Photonic Wires (TPW) already demonstrated a 0.72 collection efficiency, with TPWs were the apex is the sharp end of the cone. Going to alternate designs, still based on the idea of the adiabatic deconfinement...... of the quasi-Gaussian emission mode, but with inverted TPW where the apex is the cone's base, leads to even larger efficiencies. In addition, these inverted TPWs make the electric pumping of the emitters compatible with these large efficiencies....

  13. Brillouin lasing in single-mode tapered optical fiber with inscribed fiber Bragg grating array

    Science.gov (United States)

    Popov, S. M.; Butov, O. V.; Chamorovskiy, Y. K.; Isaev, V. A.; Kolosovskiy, A. O.; Voloshin, V. V.; Vorob'ev, I. L.; Vyatkin, M. Yu.; Mégret, P.; Odnoblyudov, M.; Korobko, D. A.; Zolotovskii, I. O.; Fotiadi, A. A.

    2018-06-01

    A tapered optical fiber has been manufactured with an array of fiber Bragg gratings (FBG) inscribed during the drawing process. The total fiber peak reflectivity is 5% and the reflection bandwidth is ∼3.5 nm. A coherent frequency domain reflectometry has been applied for precise profiling of the fiber core diameter and grating reflectivity both distributed along the whole fiber length. These measurements are in a good agreement with the specific features of Brillouin lasing achieved in the semi-open fiber cavity configuration.

  14. Impaction Force Influences Taper-Trunnion Stability in Total Hip Arthroplasty.

    Science.gov (United States)

    Danoff, Jonathan R; Longaray, Jason; Rajaravivarma, Raga; Gopalakrishnan, Ananthkrishnan; Chen, Antonia F; Hozack, William J

    2018-01-31

    This study investigated the influence of femoral head impaction force, number of head strikes, the energy sequence of head strikes, and head offset on the strength of the taper-trunnion junction. Thirty titanium-alloy trunnions were mated with 36-mm zero-offset cobalt-chromium femoral heads of corresponding taper angle. A drop tower impacted the head with 2.5J or 8.25J, resulting in 6 kN or 14 kN impaction force, respectively, in a single strike or combinations of 6 kN + 14 kN or 14 kN + 14 kN. In addition, ten 36-mm heads with -5 and +5 offset were impacted with sequential 14 kN + 14 kN strikes. Heads were subsequently disassembled using a screw-driven mechanical testing frame, and peak distraction force was recorded. Femoral head pull-off force was 45% the strike force, and heads struck with a single 14 kN impact showed a pull-off force twice that of the 6 kN group. Two head strikes with the same force did not improve pull-off force for either 6 kN (P = .90) or 14 kN (P = .90). If the forces of the 2 impactions varied, but either impact measured 14 kN, a 51% higher pull-off force was found compared to impactions of either 6 kN or 6 kN + 6 kN. Femoral head offset did not significantly change the pull-off force among -5, 0, and +5 heads (P = .37). Femoral head impaction force influenced femoral head trunnion-taper stability, whereas offset did not affect pull-off force. Multiple head strikes did not add additional stability, as long as a single strike achieved 14 kN force at the mallet-head impactor interface. Insufficient impaction force may lead to inadequate engagement of the trunnion-taper junction. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Modal demultiplexing properties of tapered and nanostructured optical fibers for in vivo optogenetic control of neural activity.

    Science.gov (United States)

    Pisanello, Marco; Della Patria, Andrea; Sileo, Leonardo; Sabatini, Bernardo L; De Vittorio, Massimo; Pisanello, Ferruccio

    2015-10-01

    Optogenetic approaches to manipulate neural activity have revolutionized the ability of neuroscientists to uncover the functional connectivity underlying brain function. At the same time, the increasing complexity of in vivo optogenetic experiments has increased the demand for new techniques to precisely deliver light into the brain, in particular to illuminate selected portions of the neural tissue. Tapered and nanopatterned gold-coated optical fibers were recently proposed as minimally invasive multipoint light delivery devices, allowing for site-selective optogenetic stimulation in the mammalian brain [Pisanello , Neuron82, 1245 (2014)]. Here we demonstrate that the working principle behind these devices is based on the mode-selective photonic properties of the fiber taper. Using analytical and ray tracing models we model the finite conductance of the metal coating, and show that single or multiple optical windows located at specific taper sections can outcouple only specific subsets of guided modes injected into the fiber.

  16. 16 W output power by high-efficient spectral beam combining of DBR-tapered diode lasers

    DEFF Research Database (Denmark)

    Müller, André; Vijayakumar, Deepak; Jensen, Ole Bjarlin

    2011-01-01

    output power achieved by spectral beam combining of two single element tapered diode lasers. Since spectral beam combining does not affect beam propagation parameters, M2-values of 1.8 (fast axis) and 3.3 (slow axis) match the M2- values of the laser with lowest spatial coherence. The principle......Up to 16 W output power has been obtained using spectral beam combining of two 1063 nm DBR-tapered diode lasers. Using a reflecting volume Bragg grating, a combining efficiency as high as 93.7% is achieved, resulting in a single beam with high spatial coherence. The result represents the highest...... of spectral beam combining used in our experiments can be expanded to combine more than two tapered diode lasers and hence it is expected that the output power may be increased even further in the future....

  17. 16 W output power by high-efficient spectral beam combining of DBR-tapered diode lasers.

    Science.gov (United States)

    Müller, André; Vijayakumar, Deepak; Jensen, Ole Bjarlin; Hasler, Karl-Heinz; Sumpf, Bernd; Erbert, Götz; Andersen, Peter E; Petersen, Paul Michael

    2011-01-17

    Up to 16 W output power has been obtained using spectral beam combining of two 1063 nm DBR-tapered diode lasers. Using a reflecting volume Bragg grating, a combining efficiency as high as 93.7% is achieved, resulting in a single beam with high spatial coherence. The result represents the highest output power achieved by spectral beam combining of two single element tapered diode lasers. Since spectral beam combining does not affect beam propagation parameters, M2-values of 1.8 (fast axis) and 3.3 (slow axis) match the M2-values of the laser with lowest spatial coherence. The principle of spectral beam combining used in our experiments can be expanded to combine more than two tapered diode lasers and hence it is expected that the output power may be increased even further in the future.

  18. Microtomography-based comparison of reciprocating single-file F2 ProTaper technique versus rotary full sequence.

    Science.gov (United States)

    Paqué, Frank; Zehnder, Matthias; De-Deus, Gustavo

    2011-10-01

    A preparation technique with only 1 single instrument was proposed on the basis of the reciprocating movement of the F2 ProTaper instrument. The present study was designed to quantitatively assess canal preparation outcomes achieved by this technique. Twenty-five extracted human mandibular first molars with 2 separate mesial root canals were selected. Canals were randomly assigned to 1 of the 2 experimental groups: group 1, rotary conventional preparation by using ProTaper, and group 2, reciprocate instrumentation with 1 single ProTaper F2 instrument. Specimens were scanned initially and after root canal preparation with an isotropic resolution of 20 μm by using a micro-computed tomography system. The following parameters were assessed: changes in dentin volume, percentage of shaped canal walls, and degree of canal transportation. In addition, the time required to reach working length with the F2 instrument was recorded. Preoperatively, there were no differences regarding root canal curvature and volume between experimental groups. Overall, instrumentation led to enlarged canal shapes with no evidence of preparation errors. There were no statistical differences between the 2 preparation techniques in the anatomical parameters assessed (P > .01), except for a significantly higher canal transportation caused by the reciprocating file in the coronal canal third. On the other hand, preparation was faster by using the single-file technique (P ProTaper technique and conventional ProTaper full-sequence rotary approach were similar. However, the single-file F2 ProTaper technique was markedly faster in reaching working length. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. The seating mechanics of head-neck modular tapers in vitro: Load-displacement measurements, moisture, and rate effects.

    Science.gov (United States)

    Ouellette, Eric S; Shenoy, Aarti A; Gilbert, Jeremy L

    2018-04-01

    The mechanically assisted crevice corrosion performance of head-neck modular tapers is a significant concern in orthopedic biomaterials. Fretting crevice corrosion processes in modular tapers are thought to be influenced by a wide array of factors including seating mechanics of the junction, hence there is a need for in vitro test methods that can assess their performance. This study presented a test method to directly measure the load-displacement seating mechanics of modular tapers and used this method to compare the seating mechanics for different tapers, moisture, seating loads and seating rates. Seating mechanics were explored whereby the instantaneous load-displacement behavior of the head seating onto the neck is captured and used to define the mechanics of seating. Two distinct taper design/material combinations were assembled wet or dry using axially applied loads (500, 1,000, 2,000, and 4,000 N) at two loading rates of 100 and 10 4  N/s (n = 5 for each condition) using a servohydraulic test frame. The results showed that pull-off strength scaled with seating load and ranged between 43% and 68% of seating load depending on sample and wetness. Tapers seated wet had higher pull-off strengths (2,200 ± 300 N) than those seated dry (1,800 ± 200 N, p mechanics (load-displacement plots) varied due to sample type and due to wetness with differences in seating energy, seating stiffness, and seating displacement. These results show the detailed mechanics of seating during assembly and provide significant insight into the complex interplay of factors associated with even "ideal" seating (axial, quasistatic) loading. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1164-1172, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  20. Narrow line width operation of a 980 nm gain guided tapered diode laser bar

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Barrientos-Barria, Jessica

    2011-01-01

    We demonstrate two different schemes for the spectral narrowing of a 12 emitter 980 nm gain guided tapered diode laser bar. In the first scheme, a reflective grating has been used in a Littman Metcalf configuration and the wavelength of the laser emission could be narrowed down from more than 5.......5 nm in the free running mode to 0.04 nm (FWHM) at an operating current of 30 A with an output power of 8 W. The spectrum was found to be tunable within a range of 16 nm. In the second scheme, a volume Bragg grating has been used to narrow the wavelength of the laser bar from over 5 nm to less than 0.......2 nm with an output of 5 W at 20 A. To our knowledge, this is the first time spectral narrowing has been performed on a gain guided tapered diode laser bar. In the Littman Metcalf configuration, the spectral brightness has been increased by 86 times and in the volume Bragg grating cavity the spectral...

  1. All-fiber radially/azimuthally polarized lasers based on mode coupling of tapered fibers.

    Science.gov (United States)

    Mao, Dong; He, Zhiwen; Lu, Hua; Li, Mingkun; Zhang, Wending; Cui, Xiaoqi; Jiang, Biqiang; Zhao, Jianlin

    2018-04-01

    We demonstrate a mode converter with an insertion loss of 0.36 dB based on mode coupling of tapered single-mode and two-mode fibers, and realize all-fiber flexible cylindrical vector lasers at 1550 nm. Attributing to the continuous distribution of a tangential electric field at taper boundaries, the laser is switchable between the radially and azimuthally polarized states by adjusting the input polarization. In the temporal domain, the operation is controllable among continuous-wave, Q-switched, and mode-locked statuses by changing the saturable absorber or pump strength. The duration of Q-switched radially/azimuthally polarized laser spans from 10.4/10.8 to 6/6.4 μs at the pump range of 38 to 58 mW, while that of the mode-locked pulse varies from 39.2/31.9 to 5.6/5.2 ps by controlling the laser bandwidth. The proposed laser combines the features of a cylindrical vector beam, a fiber laser, and an ultrafast pulse, providing a special and cost-effective source for practical applications.

  2. Torsional Vibrations of a Conic Shaft with Opposite Tapers Carrying Arbitrary Concentrated Elements

    Directory of Open Access Journals (Sweden)

    Jia-Jang Wu

    2013-01-01

    Full Text Available The purpose of this paper is to present the exact solution for free torsional vibrations of a linearly tapered circular shaft carrying a number of concentrated elements. First of all, the equation of motion for free torsional vibration of a conic shaft is transformed into a Bessel equation, and, based on which, the exact displacement function in terms of Bessel functions is obtained. Next, the equations for compatibility of deformations and equilibrium of torsional moments at each attaching point (including the shaft ends between the concentrated elements and the conic shaft with positive and negative tapers are derived. From the last equations, a characteristic equation of the form is obtained. Then, the natural frequencies of the torsional shaft are determined from the determinant equation , and, corresponding to each natural frequency, the column vector for the integration constants, , is obtained from the equation . Substitution of the last integration constants into the associated displacement functions gives the corresponding mode shape of the entire conic shaft. To confirm the reliability of the presented theory, all numerical results obtained from the exact method are compared with those obtained from the conventional finite element method (FEM and good agreement is achieved.

  3. Numerical Investigation of Oxygenated and Deoxygenated Blood Flow through a Tapered Stenosed Arteries in Magnetic Field.

    Directory of Open Access Journals (Sweden)

    M Y Abdollahzadeh Jamalabadi

    Full Text Available Current paper is focused on transient modeling of blood flow through a tapered stenosed arteries surrounded a by solenoid under the presence of heat transfer. The oxygenated and deoxygenated blood are considered here by the Newtonian and Non-Newtonian fluid (power law and Carreau-Yasuda models. The governing equations of bio magnetic fluid flow for an incompressible, laminar, homogeneous, non-Newtonian are solved by finite volume method with SIMPLE algorithm for structured grid. Both magnetization and electric current source terms are well thought-out in momentum and energy equations. The effects of fluid viscosity model, Hartmann number, and magnetic number on wall shear stress, shearing stress at the stenosis throat and maximum temperature of the system are investigated and are optimized. The current study results are in agreement with some of the existing findings in the literature and are useful in thermal and mechanical design of spatially varying magnets to control the drug delivery and biomagnetic fluid flows through tapered arteries.

  4. Mechanical properties of ProTaper Gold nickel-titanium rotary instruments.

    Science.gov (United States)

    Elnaghy, A M; Elsaka, S E

    2016-11-01

    To evaluate and compare the resistance to cyclic fatigue and torsional stress, flexibility and surface microhardness of ProTaper Gold (PTG; Dentsply, Tulsa Dental Specialties, Tulsa, OK, USA) system with ProTaper Universal (PTU; Dentsply Maillefer, Ballaigues, Switzerland). PTG and PTU instruments were rotated in simulated canals and the number of cycles to failure was recorded to assess their cyclic fatigue resistance. Torsional strength was measured using a torsiometer after fixing firmly the apical 3 mm of the instrument. A scanning electron microscope was used to characterize the topographic features of the fracture surfaces of the broken instruments. The instruments were tested for bending resistance using cantilever-bending test. Vickers microhardness was measured on the cross section of instruments with 300 g load and 15 s dwell time. Data were analysed statistically using independent t-tests. Statistical significance was set at P hand, PTU instruments were associated with higher resistance to torsional stress and microhardness than PTG instruments (P < 0.001). After torsional tests, the fractured cross-sectional surfaces revealed skewed dimples near the centre of the fracture surfaces and circular abrasion streaks. The PTG instrument had improved resistance to cyclic fatigue and flexibility compared with PTU. PTU instruments had improved resistance to torsional stress and microhardness compared with PTG. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  5. Electrochemical impedance spectroscopy investigation on the clinical lifetime of ProTaper rotary file system.

    Science.gov (United States)

    Penta, Virgil; Pirvu, Cristian; Demetrescu, Ioana

    2014-01-01

    The main objective of the current paper is to show that electrochemical impedance spectroscopy (EIS) could be a method for evaluating and predicting of ProTaper rotary file system clinical lifespan. This particular aspect of everyday use of the endodontic files is of great importance in each dental practice and has profound clinical implications. The method used for quantification resides in the electrochemical impedance spectroscopy theory and has in its main focus the characteristics of the surface titanium oxide layer. This electrochemical technique has been adapted successfully to identify the quality of the Ni-Ti files oxide layer. The modification of this protective layer induces changes in corrosion behavior of the alloy modifying the impedance value of the file. In order to assess the method, 14 ProTaper sets utilized on different patients in a dental clinic have been submitted for testing using EIS. The information obtained in regard to the surface oxide layer has offered an indication of use and proves that the said layer evolves with each clinical application. The novelty of this research is related to an electrochemical technique successfully adapted for Ni-Ti file investigation and correlation with surface and clinical aspects.

  6. Study of tapered glass capillary focusing MeV ion beam

    International Nuclear Information System (INIS)

    Gong Zhiyu; Yan Sha; Ma Hongji; Nie Rui; Xue Jianming; Wang Yugang

    2012-01-01

    In recent years, tapered glass capillary ion beam focusing is developing rapidly. It is attractive for simple, compact, low cost and easy use. However, the focusing mechanism for MeV ion beams is still indistinct. We present several experimental results of focusing 2 MeV He + beam. Ion beams were focused by tapered glass capillaries with various outlet inner diameters from several micron to hundred micron. The current densities, angle divergences and energy spectra of the transmitted ion beams are measured. The results proved that 2 MeV He + ions can focused and guided by our capillaries. The energy spectra show that a great part of transmitted ions experienced obvious energy loss, which is different from results of others research groups. We discussed the reason and charged it to the larger incident angle. Considered the incident ions with larger incident angle, the charge will distribute in a layer of micro meter depth in the capillary’s inner wall, but not the surface. The energy loss and many other spectra characters can be explained in this way.

  7. Forearc Basin Stratigraphy and Interactions With Accretionary Wedge Growth According to the Critical Taper Concept

    Science.gov (United States)

    Noda, Atsushi

    2018-03-01

    Forearc basins are important constituents of sediment traps along subduction zones; the basin stratigraphy records various events that the basin experienced. Although the linkage between basin formation and accretionary wedge growth suggests that mass balance exerts a key control on their evolution, the interaction processes between basin and basement remain poorly understood. This study performed 2-D numerical simulations in which basin stratigraphy was controlled by changes in sediment fluxes with accretionary wedge growth according to the critical taper concept. The resultant stratigraphy depended on the degree of filling (i.e., whether the basin was underfilled or overfilled) and the volume balance between the sediment flux supplied to the basin from the hinterland and the accommodation space in the basin. The trenchward progradation of deposition with onlapping contacts on the trenchside basin floor occurred during the underfilled phase, which formed a wedge-shaped sedimentary unit. In contrast, the landward migration of the depocenter, with the tilting of strata, was characteristic for the overfilled phase. Condensed sections marked stratigraphic boundaries, indicating when sediment supply or accommodation space was limited. The accommodation-limited intervals could have formed during the end of wedge uplift or when the taper angle decreased and possibly associated with the development of submarine canyons as conduits for bypassing sediments from the hinterland. Variations in sediment fluxes and their balance exerted a strong influence on the stratigraphic patterns in forearc basins. Assessing basin stratigraphy could be a key to evaluating how subduction zones evolve through their interactions with changing surface processes.

  8. Whole-organ cell shape analysis reveals the developmental basis of ascidian notochord taper.

    Science.gov (United States)

    Veeman, Michael T; Smith, William C

    2013-01-15

    Here we use in toto imaging together with computational segmentation and analysis methods to quantify the shape of every cell at multiple stages in the development of a simple organ: the notochord of the ascidian Ciona savignyi. We find that cell shape in the intercalated notochord depends strongly on anterior-posterior (AP) position, with cells in the middle of the notochord consistently wider than cells at the anterior or posterior. This morphological feature of having a tapered notochord is present in many chordates. We find that ascidian notochord taper involves three main mechanisms: Planar Cell Polarity (PCP) pathway-independent sibling cell volume asymmetries that precede notochord cell intercalation; the developmental timing of intercalation, which proceeds from the anterior and posterior towards the middle; and the differential rates of notochord cell narrowing after intercalation. A quantitative model shows how the morphology of an entire developing organ can be controlled by this small set of cellular mechanisms. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Temperature independent refractive index measurement using a fiber Bragg grating on abrupt tapered tip

    Science.gov (United States)

    Gomes, André D.; Silveira, Beatriz; Warren-Smith, Stephen C.; Becker, Martin; Rothhardt, Manfred; Frazão, Orlando

    2018-05-01

    A fiber Bragg grating was inscribed in an abrupt fiber taper using a femtosecond laser and phase-mask interferometer. The abrupt taper transition allows to excite a broad range of guided modes with different effective refractive indices that are reflected at different wavelengths according to Bragg's law. The multimode-Bragg reflection expands over 30 nm in the telecom-C-band. This corresponds to a mode-field overlap of up to 30% outside of the fiber, making the device suitable for evanescent field sensing. Refractive index and temperature measurements are performed for different reflection peaks. Temperature independent refractive index measurements are achieved by considering the difference between the wavelength shifts of two measured reflection peaks. A minimum refractive index sensitivity of 16 ± 1 nm/RIU was obtained in a low refractive index regime (1.3475-1.3720) with low influence of temperature (-0.32 ± 0.06 pm/°C). The cross sensitivity for this structure is 2.0 × 10-5 RIU/°C. The potential for simultaneous measurement of refractive index and temperature is also studied.

  10. Plasma Density Tapering for Laser Wakefield Acceleration of Electrons and Protons

    International Nuclear Information System (INIS)

    Ting, A.; Gordon, D.; Kaganovich, D.; Sprangle, P.; Helle, M.; Hafizi, B.

    2010-01-01

    Extended acceleration in a Laser Wakefield Accelerator can be achieved by tailoring the phase velocity of the accelerating plasma wave, either through profiling of the density of the plasma or direct manipulation of the phase velocity. Laser wakefield acceleration has also reached a maturity that proton acceleration by wakefield could be entertained provided we begin with protons that are substantially relativistic, ∼1 GeV. Several plasma density tapering schemes are discussed. The first scheme is called ''bucket jumping'' where the plasma density is abruptly returned to the original density after a conventional tapering to move the accelerating particles to a neighboring wakefield period (bucket). The second scheme is designed to specifically accelerate low energy protons by generating a nonlinear wakefield in a plasma region with close to critical density. The third scheme creates a periodic variation in the phase velocity by beating two intense laser beams with laser frequency difference equal to the plasma frequency. Discussions and case examples with simulations are presented where substantial acceleration of electrons or protons could be obtained.

  11. Thermal decomposition of hydrotalcite-like compounds studied by a novel tapered element oscillating microbalance (TEOM)

    International Nuclear Information System (INIS)

    Perez-Ramirez, Javier; Abello, Sonia

    2006-01-01

    For the first time, we report on the application of a tapered element oscillating microbalance (TEOM) as a novel technique to investigate the thermal decomposition of hydrotalcite-like compounds (HTlcs) in air. Experiments were performed in the temperature range of 323-973 K with Mg-Al, Ni-Al, and Co-Al-HTlcs. The TEOM technique measures mass changes based on inertial forces, presenting important advantages over conventional thermogravimetric analyzers, such as the very rapid time response and the well-defined flow pattern. In general terms, excellent agreement between TEOM, TGA, and DTA techniques during HTlc decomposition was obtained. Interestingly, transition temperatures in the TEOM were lower than in TGA and DTA, particularly for removal of interlayer water but also for dehydroxylation of the brucite-like layers and decarbonation. This was attributed to the flow-through operation in the tapered element of the TEOM as compared to the recognized gas stagnancy and bypass in sample crucibles of conventional thermogravimetric analyzers. Our results conclude that the TEOM technique is suitable for temperature-programmed studies. However, due to its operation principle, blank runs are required in contrast to the more automatic operation in commercial thermogravimetric units. Besides, a careful sample loading and packing in the micro-reactor is essential for reproducible results

  12. Resin Viscosity Influence on Fiber Compaction in Tapered Resin Injection Pultrusion Manufacturing

    Science.gov (United States)

    Masuram, N. B.; Roux, J. A.; Jeswani, A. L.

    2018-06-01

    Viscosity of the liquid resin effects the chemical and mechanical properties of the pultruded composite. In resin injection pultrusion manufacturing the liquid resin is injected into a specially designed tapered injection chamber through the injection slots present on top and bottom of the chamber. The resin is injected at a pressure so as to completely wetout the fiber reinforcements inside the tapered injection chamber. As the resin penetrates through the fibers, the resin also pushes the fibers away from the wall towards the center of chamber causing compaction of the fiber reinforcements. The fibers are squeezed together due to compaction, making resin penetration more difficult; thus higher resin injection pressures are required to efficaciously penetrate through the compacted fibers and achieve complete wetout. The impact of resin viscosity on resin flow, fiber compaction, wetout and on the final product is further discussed. Injection chamber design predominantly effects the resin flow inside the chamber and the minimum injection pressure required to completely wet the fibers. Therefore, a desirable injection chamber design is such that wetout occurs at lower injection pressures and at low internal pressures inside the injection chamber.

  13. Influence of a glide path on the dentinal crack formation of ProTaper Next system

    Directory of Open Access Journals (Sweden)

    Sevinç Aktemur Türker

    2015-11-01

    Full Text Available Objectives The aim was to evaluate dentinal crack formation after root canal preparation with ProTaper Next system (PTN with and without a glide path. Materials and Methods Forty-five mesial roots of mandibular first molars were selected. Fifteen teeth were left unprepared and served as controls. The experimental groups consist of mesiobuccal and mesiolingual root canals of remaining 30 teeth, which were divided into 2 groups (n = 15: Group PG/PTN, glide path was created with ProGlider (PG and then canals were shaped with PTN system; Group PTN, glide path was not prepared and canals were shaped with PTN system only. All roots were sectioned perpendicular to the long axis at 1, 2, 3, 4, 6, and 8 mm from the apex, and the sections were observed under a stereomicroscope. The presence/absence of cracks was recorded. Data were analyzed with chi-square tests with Yates correction. Results There were no significant differences in crack formation between the PTN with and without glide path preparation. The incidence of cracks observed in PG/PTN and PTN groups was 17.8% and 28.9%, respectively. Conclusions The creation of a glide path with ProGlider before ProTaper Next rotary system did not influence dentinal crack formation in root canals.

  14. Deep and tapered silicon photonic crystals for achieving anti-reflection and enhanced absorption.

    Science.gov (United States)

    Hung, Yung-Jr; Lee, San-Liang; Coldren, Larry A

    2010-03-29

    Tapered silicon photonic crystals (PhCs) with smooth sidewalls are realized using a novel single-step deep reactive ion etching. The PhCs can significantly reduce the surface reflection over the wavelength range between the ultra-violet and near-infrared regions. From the measurements using a spectrophotometer and an angle-variable spectroscopic ellipsometer, the sub-wavelength periodic structure can provide a broad and angular-independent antireflective window in the visible region for the TE-polarized light. The PhCs with tapered rods can further reduce the reflection due to a gradually changed effective index. On the other hand, strong optical resonances for TM-mode can be found in this structure, which is mainly due to the existence of full photonic bandgaps inside the material. Such resonance can enhance the optical absorption inside the silicon PhCs due to its increased optical paths. With the help of both antireflective and absorption-enhanced characteristics in this structure, the PhCs can be used for various applications.

  15. VOLUME AND TAPER EQUATIONS FOR COMMERCIAL STEMS OF Nothofagus obliqua AND N. alpina

    Directory of Open Access Journals (Sweden)

    Hernan Attis Beltran

    2017-09-01

    Full Text Available Timber volume of standing trees is essential information for management decisions. The increasing need to optimize the potential capacity of forests maintaining their conservation, requires the quantification of the different potential possible timber products. The aim was to adjust taper equations to determine volumes of different timber products for commercial stems of Nothofagus alpina and N. obliqua. Trees of both species were randomly selected in harvesting areas of Lanin National Park (Argentina. Trees were felled and cut into commercial logs, measuring diameter with bark at different heights up to the beginning of the crown, and for each tree the diameter at breast height and total height. Five taper equations were selected and non-linear regression processes were employed for the fittings. We obtained the volume through the integration of the stem profile equation and the rotation in the space thereof through solid of revolution. The Bennet and Swindel (1972 model was selected for both Nothofagus species, obtaining similar equation parameters and differences were observed at the top of the stems of larger trees. For this the use of an integrated model is not recommended. With the obtained equations it is possible to: (i estimatevolume at different heights and for different commercial diameters, and (ii predict the height at which both species reach to a certain diameter. The model presented some statistical limitations (e.g. multicollinearity, however, the fitting of the equation and the easy understanding of the outputs support it as a useful tool in a broad range of forest applications.

  16. Characterization of string cavitation in large-scale Diesel nozzles with tapered holes

    Science.gov (United States)

    Gavaises, M.; Andriotis, A.; Papoulias, D.; Mitroglou, N.; Theodorakakos, A.

    2009-05-01

    The cavitation structures formed inside enlarged transparent replicas of tapered Diesel valve covered orifice nozzles have been characterized using high speed imaging visualization. Cavitation images obtained at fixed needle lift and flow rate conditions have revealed that although the conical shape of the converging tapered holes suppresses the formation of geometric cavitation, forming at the entry to the cylindrical injection hole, string cavitation has been found to prevail, particularly at low needle lifts. Computational fluid dynamics simulations have shown that cavitation strings appear in areas where large-scale vortices develop. The vortical structures are mainly formed upstream of the injection holes due to the nonuniform flow distribution and persist also inside them. Cavitation strings have been frequently observed to link adjacent holes while inspection of identical real-size injectors has revealed cavitation erosion sites in the area of string cavitation development. Image postprocessing has allowed estimation of their frequency of appearance, lifetime, and size along the injection hole length, as function of cavitation and Reynolds numbers and needle lift.

  17. Effect of oxygen on ethanol fermentation in packed-bed tapered-column reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hamamci, H.; Ryu, D.D.Y.

    1988-07-01

    In ethanol production with immobilized yeast a major problem is the provision of nutrients to these highly concentrated cells. O/sub 2/ being one of the nutrients of utmost importance to yeast cells, was fed into a column packed with beads with a cell loading of more than 40 g/l. Since addition of large volume of air or O/sub 2/ to a cylindrical column reactor would aggravate the problems of pressure build up and channelling caused by the evolving CO/sub 2/ gas, a tapered-column reactor and pulsed flow of oxygen gas was used. The supplement of O/sub 2/ gas to the tapered column increased the productivity from 21.1 g ethanol x (l gel x h)/sup -1/ to 26.7 g x (l gelxh)/sup -1/, when the ethanol concentration at the outlet was about 80 g/l. The yield coefficient of ethanol was also increased from 0.41 g ethanol/g glucose to 0.43 after O/sub 2/ supplement was started. The effects of frequency and duration of O/sub 2/ supplement were also determined.

  18. Artificial Material Integrated Ultra-wideband Tapered Slot Antenna for Gain Enhancement with Band Notch Characteristics

    Directory of Open Access Journals (Sweden)

    R. Singha

    2018-04-01

    Full Text Available The gain of the ultra-wideband tapered slot antenna (TSA is enhanced by using broadband artificial material with band notch characteristics. The proposed artificial material unit cell is designed by fabricating non-resonant three S-shaped parallel metallic line on single side of the dielectric substrate which provides a longer current path compared to the parallel-line structure. The proposed S-shaped structure is printed on the top side of the tapered slot antenna in the extended substrate periodically. The effective refractive index of the artificial material is lower than antenna substrate and phase velocity in the region of artificial material is much higher than the other region. Therefore, the proposed artificial material acts like a beam focusing lens. The band notch at 5.5 GHz is achieved by creating a split ring resonator (SRR slot near the balun. The basic and artificial material loaded TSAs are fabricated and the measurement results show that the gain of the basic antenna has been increased by 1.6 dBi. At the same time, the proposed antenna achieves a VSWR below 2 from 3 to 11 GHz except at 5.5 GHz with a notch band from 5.1 to 5.8 GHz for band rejection of wireless local area network (WLAN application.

  19. Management of female congenital short patulous urethra with urethral tapering and pubovaginal sling: A report of two cases.

    Science.gov (United States)

    Gahlawat, Sumit; Goel, Hemant; Khattar, Nikhil

    2018-01-01

    Congenital short patulous urethra is a rare entity and may be associated with developmental anomalies of mullerian ducts or urogenital sinus. We report the management of two cases of congenital short patulous urethra with stress urinary incontinence (SUI). Both the patients presented with SUI; one was diagnosed with Mayer-Rokitansky-Kuster-Hauser (MRKH) syndrome and the other had uterus didelphys with longitudinally septated vagina. Both patients were successfully managed by excisional tapering of the urethra and pubovaginal sling placement. SUI with congenital short patulous urethra can be managed with excisional tapering of urethra and pubovaginal sling placement.

  20. Cross two photon absorption in a silicon photonic crystal waveguide fiber taper coupler with a physical junction

    Energy Technology Data Exchange (ETDEWEB)

    Sarkissian, Raymond, E-mail: RaymondSark@gmail.com; O' Brien, John [Electrophysics department, University of Southern California, Los Angeles, California 90089 (United States)

    2015-01-21

    Cross two photon absorption in silicon is characterized using a tapered fiber photonic crystal silicon waveguide coupler. There is a physical junction between the tapered fiber and the waveguide constituting a stand-alone device. This device is used to obtain the spectrum for cross two photon absorption coefficient per unit volume of interaction between photons of nondegenerate energy. The corresponding Kerr coefficient per unit volume of interaction is also experimentally extracted. The thermal resistance of the device is also experimentally determined and the response time of the device is estimated for on-chip all-optical signal processing and data transfer between optical signals of different photon energies.

  1. Single-pass high-gain tapered free-electron laser with transverse diffraction in the postsaturation regime

    Directory of Open Access Journals (Sweden)

    Cheng-Ying Tsai

    2018-06-01

    Full Text Available It has been well known that the resonant interaction of an ultrarelativistic electron beam and the radiation field in the single-pass high-gain free electron laser (FEL amplifier leads to the optical gain guiding. The transverse Laplacian term of the slowly varying wave equation in the linear regime can be approximated as a constant detuning parameter, i.e., |∇_{⊥}^{2}|∼k_{R}/z_{R} where k_{R} is the resonant wave number and z_{R} is the Rayleigh range of the laser. In the post-saturation regime, the radiation power begins to oscillate about an equilibrium for the untapered case while continues to grow by undulator tapering. Moreover, in this regime the gain guiding decreases and the simple constant detune is no longer valid. In this paper we study the single-pass high-gain FEL performance in the post-saturation regime with inclusion of diffraction effect and undulator tapering. Our analysis relies upon two constants of motion, one from the energy conservation and the other from the adiabatic invariant of the action variable. By constructing a two-dimensional axisymmetric wave equation and the coupled one-dimensional electron dynamical equations, the performance of a tapered FEL in the postsaturation regime can be analyzed, including the fundamental mode profile, the power efficiency and the scaled energy spread. We begin the analytical investigation with two different axisymmetric electron beam profiles, the uniform and bounded parabolic ones. It is found that the tapered FEL power efficiency can be smaller but close to the taper ratio provided the resonant phase remains constant and the beam-wave is properly matched. Such a tapered efficiency is nearly independent of transverse electron beam size before significant electron detrapping occurs. This is essentially different from the untapered case, where the power extraction efficiency is around the essential FEL gain bandwidth (or ρ, the Pierce or FEL parameter and depends on the beam

  2. A combined experimental and finite element approach to analyse the fretting mechanism of the head-stem taper junction in total hip replacement

    NARCIS (Netherlands)

    Bitter, T.; Khan, I.; Marriott, T.; Lovelady, E.; Verdonschot, N.J.; Janssen, D.W.

    2017-01-01

    Fretting corrosion at the taper interface of modular hip implants has been implicated as a possible cause of implant failure. This study was set up to gain more insight in the taper mechanics that lead to fretting corrosion. The objectives of this study therefore were (1) to select experimental

  3. Jet impinging onto a laser drilled tapered hole: Influence of tapper location on heat transfer and skin friction at hole surface

    Science.gov (United States)

    Shuja, S. Z.; Yilbas, B. S.

    2013-02-01

    Jet emerging from a conical nozzle and impinging onto a tapered hole in relation to laser drilling is investigated and the influence taper location on the heat transfer and skin friction at the hole wall surface is examined. The study is extended to include four different gases as working fluid. The Reynolds stress model is incorporated to account for the turbulence effect in the flow field. The hole wall surface temperature is kept at 1500 K to resemble the laser drilled hole. It is found that the location of tapering in the hole influences the heat transfer rates and skin friction at the hole wall surface. The maximum skin friction coefficient increases for taper location of 0.25 H, where H is the thickness of the workpiece, while Nusselt number is higher in the hole for taper location of 0.75 H.

  4. Mental health, fatigue and function are associated with increased risk of disease flare following TNF inhibitor tapering in patients with rheumatoid arthritis: an exploratory analysis of data from the Optimizing TNF Tapering in RA (OPTTIRA) trial.

    Science.gov (United States)

    Bechman, Katie; Sin, Fang En; Ibrahim, Fowzia; Norton, Sam; Matcham, Faith; Scott, David Lloyd; Cope, Andrew; Galloway, James

    2018-01-01

    Tapering of anti-tumour necrosis factor (TNF) therapy appears feasible, safe and effective in selected patients with rheumatoid arthritis (RA). Depression is highly prevalent in RA and may impact on flare incidence through various mechanisms. This study aims to investigate if psychological states predict flare in patients' dose tapering their anti-TNF therapy. This study is a post-hoc analysis of the Optimizing TNF Tapering in RA trial, a multicentre, randomised, open-label study investigating anti-TNF tapering in RA patients with sustained low disease activity. Patient-reported outcomes (Health Assessment Questionnaire, EuroQol 5-dimension scale, Functional Assessment of Chronic Illness Therapy fatigue scale (FACIT-F), 36-Item Short Form Survey (SF-36)) were collected at baseline. The primary outcome was flare, defined as an increase in 28-joint count Disease Activity Score (DAS28) ≥0.6 and ≥1 swollen joint. Discrete-time survival models were used to identify patient-reported outcomes that predict flare. Ninety-seven patients were randomised to taper their anti-TNF dose by either 33% or 66%. Forty-one patients flared. Higher baseline DAS28 score was associated with flare (adjusted HR 1.96 (95% CI 1.18 to 3.24), p=0.01). Disability (SF-36 physical component score), fatigue (FACIT-F) and mental health (SF-36 mental health subscale (MH)) predicted flare in unadjusted models. In multivariate analyses, only SF-36 MH remained a statistically significant predictor of flare (adjusted HR per 10 units 0.74 (95% CI 0.60 to 0.93), p=0.01). Baseline DAS28 and mental health status are independently associated with flare in patients who taper their anti-TNF therapy. Fatigue and function also associate with flare but the effect disappears when adjusting for confounders. Given these findings, mental health and functional status should be considered in anti-TNF tapering decisions in order to optimise the likelihood of success. EudraCT Number: 2010-020738-24; ISRCTN: 28955701

  5. Generating a 2.4-W cw Green Laser by Intra-Cavity Frequency Doubling of a Diode-Pumped Nd:GdVO4 Laser with a MgO:PPLN Crystal

    International Nuclear Information System (INIS)

    Lu Jun; Liu Yan-Hua; Zhao Gang; Hu Xiao-Peng; Zhu Shi-Ning

    2012-01-01

    High-power cw green laser radiation is generated by intra-cavity frequency doubling of a diode-pumped Nd:GdVO 4 laser with a MgO-doped periodically-poled LiNbO 3 (MgO:PPLN) crystal at room temperature. An average power of 2.4 W at 0.53 μm is obtained under the pump 15 W at 808 nm, corresponding to an overall optical-to-optical conversion efficiency of 16%. The M 2 factor of the green beam is 3.90 and 1.34 for the horizontal and vertical direction, respectively. In addition, the power fluctuation is measured to be about ±5%

  6. Electro-optic control of a PPLN-unpoled LiNbO3 boundary for low-voltage Q switching of an intracavity frequency-doubled Nd3+:YVO4 laser.

    Science.gov (United States)

    Torregrosa, A J; Maestre, H; Fernández-Pousa, C R; Pereda, J A; Capmany, J

    2009-08-01

    We present a simple technique to integrate an electro-optic Q switch in a periodically poled bulk lithium niobate crystal bounded by two unpoled (monodomain) regions. The technique exploits the high sensitivity to low applied electric fields of the total internal reflection condition in the periodic poled-unpoled boundary for the small grazing incidence angles associated with the diffraction of a focused Gaussian beam that propagates in the periodically poled region with its axis parallel to the boundary. When the arrangement is placed intracavity to a 1064 nm diode-pumped Nd(3+):YVO(4) laser, it performs simultaneously as a Q switch and as a second-harmonic generator, with Q switching starting at applied voltages as low as 1 V over a 500 microm thickness and with no additional optical elements.

  7. Strain analysis of different diameter Morse taper implants under overloading compressive conditions

    Directory of Open Access Journals (Sweden)

    Carolina Guimarães CASTRO

    2015-01-01

    Full Text Available The aim of this study was to evaluate the amount of deformation from compression caused by different diameters of Morse taper implants and the residual deformation after load removal. Thirty Morse taper implants lacking external threads were divided into 3 groups (n = 10 according to their diameter as follows: 3.5 mm, 4.0 mm and 5.0 mm. Two-piece abutments were fixed into the implants, and the samples were subjected to compressive axial loading up to 1500 N of force. During the test, one strain gauge remained fixed to the cervical portion of each implant to measure the strain variation. The strain values were recorded at two different time points: at the maximum load (1500 N and 60 seconds after load removal. To calculate the strain at the implant/abutment interface, a mathematical formula was applied. Data were analyzed using a one-way Anova and Tukey’s test (α = 0.05. The 5.0 mm diameter implant showed a significantly lower strain (650.5 μS ± 170.0 than the 4.0 mm group (1170.2 μS ± 374.7 and the 3.5 mm group (1388.1 μS ± 326.6 (p < 0.001, regardless of the load presence. The strain values decreased by approximately 50% after removal of the load, regardless of the implant diameter. The 5.0 mm implant showed a significantly lower strain at the implant/abutment interface (943.4 μS ± 504.5 than the 4.0 mm group (1057.4 μS ± 681.3 and the 3.5 mm group (1159.6 μS ± 425.9 (p < 0.001. According to the results of this study, the diameter influenced the strain around the internal and external walls of the cervical region of Morse taper implants; all diameters demonstrated clinically acceptable values of strain.

  8. Rapid detoxification from opioid dependence under general anaesthesia versus standard methadone tapering : abstinence rates and withdrawal distress experiences

    NARCIS (Netherlands)

    Krabbe, Paul F M; Koning, Jeroen P F; Heinen, Nadia; Laheij, Robert J F; van Cauter, R M Victory; De Jong, Cor A J

    The aim of this work was to study abstinence rates and withdrawal effects of rapid detoxification of opioid-dependents under general anaesthesia (RD-GA) compared to standard methadone tapering (SMT) using a prospective clinical trial with a follow-up of 3 months, as a preliminary study at the

  9. Rapid detoxification from opioid dependence under general anaesthesia versus standard methadone tapering: abstinence rates and withdrawal distress experiences.

    NARCIS (Netherlands)

    Krabbe, P.F.M.; Koning, J.P.; Heinen, N.; Laheij, R.J.F.; Cauter, R.M.V. van; Jong, C.A.J. de

    2003-01-01

    The aim of this work was to study abstinence rates and withdrawal effects of rapid detoxification of opioid-dependents under general anaesthesia (RD-GA) compared to standard methadone tapering (SMT) using a prospective clinical trial with a follow-up of 3 months, as a preliminary study at the

  10. 78 FR 45912 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished, From the People's Republic of...

    Science.gov (United States)

    2013-07-30

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and..., International Trade Administration, U.S. Department of Commerce, 14th Street and Constitution Avenue NW... Duty New Shipper Review AGENCY: Import Administration, International Trade Administration, Department...

  11. Dynamic behavior of liquid water transport in a tapered channel of a proton exchange membrane fuel cell cathode

    NARCIS (Netherlands)

    Akhtar, N.; Kerkhof, P.J.A.M.

    2011-01-01

    A numerical model of a proton exchange membrane fuel cell (PEMFC) cathode with a tapered channel design has been developed in order to examine the dynamic behavior of liquid water transport. Three-dimensional, transient simulations employing the level-set method (available in COMSOL 3.5a, a

  12. Detoxification with titration and tapering in gamma-hydroxybutyrate (GHB) dependent patients : The Dutch GHB monitor project

    NARCIS (Netherlands)

    Dijkstra, Boukje A G; Kamal, Rama; van Noorden, Martijn S; de Haan, Hein; Loonen, Anton J.M.; De Jong, Cor A J

    2016-01-01

    BACKGROUND AND AIMS: Gamma-hydroxybutyrate (GHB) detoxification procedures have been insufficiently studied for effectiveness and safety. Based on case reports, benzodiazepines are generally regarded as first-choice agents in GHB detoxification. Detoxification by titration and tapering (DeTiTap)

  13. High Sensitivity Refractometer Based on TiO2-Coated Adiabatic Tapered Optical Fiber via ALD Technology

    Science.gov (United States)

    Zhu, Shan; Pang, Fufei; Huang, Sujuan; Zou, Fang; Guo, Qiang; Wen, Jianxiang; Wang, Tingyun

    2016-01-01

    Atomic layer deposition (ALD) technology is introduced to fabricate a high sensitivity refractometer based on an adiabatic tapered optical fiber. Different thicknesses of titanium dioxide (TiO2) nanofilm were coated around the tapered fiber precisely and uniformly under different deposition cycles. Attributed to the higher refractive index of the TiO2 nanofilm compared to that of silica, an asymmetric Fabry–Perot (F-P) resonator could be constructed along the fiber taper. The central wavelength of the F-P resonator could be controlled by adjusting the thickness of the TiO2 nanofilm. Such a F-P resonator is sensitive to changes in the surrounding refractive index (SRI), which is utilized to realize a high sensitivity refractometer. The refractometer developed by depositing 50.9-nm-thickness TiO2 on the tapered fiber shows SRI sensitivity as high as 7096 nm/RIU in the SRI range of 1.3373–1.3500. Due to TiO2’s advantages of high refractive index, lack of toxicity, and good biocompatibility, this refractometer is expected to have wide applications in the biochemical sensing field. PMID:27537885

  14. 77 FR 2031 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished From the People's Republic of...

    Science.gov (United States)

    2012-01-13

    ... Parts Thereof, Finished and Unfinished From the People's Republic of China: Extension of the Time Limit..., International Trade Administration, U.S. Department of Commerce, 14th Street and Constitution Avenue NW..., finished and unfinished from the People's Republic of China. See Tapered Roller Bearings and Parts Thereof...

  15. Comparison of the cleaning capacity of Mtwo and Pro Taper rotary systems and manual instruments in primary teeth

    Science.gov (United States)

    Azar, Mohammad Reza; Safi, Laya; Nikaein, Afshin

    2012-01-01

    Background: Root canal cleaning is an important step in endodontic therapy. In order to develop better techniques, a new generation of endodontic instruments has been designed. The aim of this study was to compare the effectiveness of manual K-files (Mani Co, Tokyo, Japan) and two rotary systems–Mtwo (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper (VDW, Munich, Germany)–for root canal preparation in primary molars. Materials and Methods: India ink was injected to 160 mesiobuccal and distal root canals of mandibular primary molars. The teeth were randomly divided into three experimental groups and one control group. In each experimental group, either manual instruments (K-files) or rotary instruments (Mtwo or ProTaper) were used to prepare root canals. After cleaning the canals and clearing the teeth, ink removal was evaluated with a stereomicroscope. Statistical analysis was done with Kruskal–Wallis and Friedman tests. Results: There were no significant differences in cleaning efficiency between manual and rotary instruments. Only ProTaper files performed significantly better in the coronal and middle thirds than in the apical third of the root canal. Conclusion: Manual K-files and the Mtwo and ProTaper rotary systems showed equally acceptable cleaning ability in primary molar root canals. PMID:22623929

  16. Comparison of the cleaning capacity of Mtwo and ProTaper rotary systems and manual instruments in primary teeth

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Azar

    2012-01-01

    Full Text Available Background: Root canal cleaning is an important step in endodontic therapy. In order to develop better techniques, a new generation of endodontic instruments has been designed. The aim of this study was to compare the effectiveness of manual K-files (Mani Co, Tokyo, Japan and two rotary systems-Mtwo (Dentsply-Maillefer, Ballaigues, Switzerland and ProTaper (VDW, Munich, Germany-for root canal preparation in primary molars. Materials and Methods: India ink was injected to 160 mesiobuccal and distal root canals of mandibular primary molars. The teeth were randomly divided into three experimental groups and one control group. In each experimental group, either manual instruments (K-files or rotary instruments (Mtwo or ProTaper were used to prepare root canals. After cleaning the canals and clearing the teeth, ink removal was evaluated with a stereomicroscope. Statistical analysis was done with Kruskal-Wallis and Friedman tests. Results: There were no significant differences in cleaning efficiency between manual and rotary instruments. Only ProTaper files performed significantly better in the coronal and middle thirds than in the apical third of the root canal. Conclusion: Manual K-files and the Mtwo and ProTaper rotary systems showed equally acceptable cleaning ability in primary molar root canals.

  17. 76 FR 76143 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished, From the People's Republic of...

    Science.gov (United States)

    2011-12-06

    ..., the United Steel, Paper and Forestry, Rubber, Manufacturing, Energy, Allied Industrial and Service... manufacturing of tapered roller bearings and parts thereof in the United States, also notified the Department... manufacturing the domestic like product, and therefore, is an interested party pursuant to section 771(9)(D) of...

  18. Total heat loss coefficient of flat roof constructions with external insulation in tapered layers including the effects of thermal bridges

    DEFF Research Database (Denmark)

    Rose, Jørgen; Svendsen, Svend

    2005-01-01

    In order to achieve durability of flat roofs with external insulation, it is necessary to secure proper drainage of the roof, i.e. to avoid water leaking into the insulation. The design of the tapered insulation of the roof is quite difficult as requirements with respect to both drainage...

  19. 78 FR 40692 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished, From the People's Republic of...

    Science.gov (United States)

    2013-07-08

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and..., International Trade Administration, Department of Commerce. SUMMARY: The Department of Commerce (Department) is... Department selected one mandatory respondent for individual examination (i.e., Changshan Peer Bearing Co. Ltd...

  20. Tunable high-power narrow-spectrum external-cavity diode laser based on tapered amplifier at 668 nm

    DEFF Research Database (Denmark)

    Chi, Mingjun; Erbert, G.; Sumpf, B.

    2010-01-01

    A 668 nm tunable high-power narrow-spectrum diode laser system based on a tapered semiconductor optical amplifier in external cavity is demonstrated. The laser system is tunable from 659 to 675 nm. As high as 1.38 W output power is obtained at 668.35 nm. The emission spectral bandwidth is less than...

  1. Design of a tapered stripline fast Faraday cup for measurements on heavy ion beams: problems and solutions

    International Nuclear Information System (INIS)

    Marcellini, F.; Poggi, M.

    1998-01-01

    The design of a tapered stripline fast Faraday cup (TSFFC) to perform the impedance matching between the fast cup itself and the signal line (connector, cable, and amplifier) is reported here. The frequency response of the TSFFC as a high-pass filter is analyzed from a theoretical point of view and some solutions to achieve a broadband response are given

  2. Application of carbon nanotubes to topographical resolution enhancement of tapered fiber scanning near field optical microscopy probes

    Science.gov (United States)

    Huntington, S. T.; Jarvis, S. P.

    2003-05-01

    Scanning near field optical microscopy (SNOM) probes are typically tapered optical fibers with metallic coatings. The tip diameters are generally in excess of 300 nm and thus provide poor topographical resolution. Here we report on the attachment multiwalled carbon nanotubes to the probes in order to substantially enhance the topographical resolution, without adversely affecting the optical resolution.

  3. Centering Ability of ProTaper Next and WaveOne Classic in J-Shape Simulated Root Canals.

    Science.gov (United States)

    Troiano, Giuseppe; Dioguardi, Mario; Cocco, Armando; Giuliani, Michele; Fabiani, Cristiano; D'Alessandro, Alfonso; Ciavarella, Domenico; Lo Muzio, Lorenzo

    Introduction . The aim of this study was to evaluate and compare the shaping and centering ability of ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland) and WaveOne Classic systems (Dentsply Maillefer) in simulated root canals. Methods . Forty J-shaped canals in resin blocks were assigned to two groups ( n = 20 for each group). Photographic method was used to record pre- and postinstrumentation images. After superimposition, centering and shaping ability were recorded at 9 different levels from the apex using the software Autocad 2013 (Autodesk Inc., San Rafael, USA). Results . Shaping procedures with ProTaper Next resulted in a lower amount of resin removed at each reference point level. In addition, the pattern of centering ability improved after the use of ProTaper Next in 8 of 9 measurement points. Conclusions . Within the limitations of this study, shaping procedures with ProTaper Next instruments demonstrated a lower amount of resin removed and a better centering ability than WaveOne Classic system.

  4. A sensitivity-enhanced refractive index sensor using a single-mode thin-core fiber incorporating an abrupt taper.

    Science.gov (United States)

    Shi, Jie; Xiao, Shilin; Yi, Lilin; Bi, Meihua

    2012-01-01

    A sensitivity-enhanced fiber-optic refractive index (RI) sensor based on a tapered single-mode thin-core diameter fiber is proposed and experimentally demonstrated. The sensor head is formed by splicing a section of tapered thin-core diameter fiber (TCF) between two sections of single-mode fibers (SMFs). The cladding modes are excited at the first SMF-TCF interface, and then interfere with the core mode at the second interface, thus forming an inter-modal interferometer (IMI). An abrupt taper (tens of micrometers long) made by the electric-arc-heating method is utilized, and plays an important role in improving sensing sensitivity. The whole manufacture process only involves fiber splicing and tapering, and all the fabrication process can be achieved by a commercial fiber fusion splicer. Using glycerol and water mixture solution as an example, the experimental results show that the refractive index sensitivity is measured to be 0.591 nm for 1% change of surrounding RI. The proposed sensor structure features simple structure, low cost, easy fabrication, and high sensitivity.

  5. A Sensitivity-Enhanced Refractive Index Sensor Using a Single-Mode Thin-Core Fiber Incorporating an Abrupt Taper

    Directory of Open Access Journals (Sweden)

    Jie Shi

    2012-04-01

    Full Text Available A sensitivity-enhanced fiber-optic refractive index (RI sensor based on a tapered single-mode thin-core diameter fiber is proposed and experimentally demonstrated. The sensor head is formed by splicing a section of tapered thin-core diameter fiber (TCF between two sections of single-mode fibers (SMFs. The cladding modes are excited at the first SMF-TCF interface, and then interfere with the core mode at the second interface, thus forming an inter-modal interferometer (IMI. An abrupt taper (tens of micrometers long made by the electric-arc-heating method is utilized, and plays an important role in improving sensing sensitivity. The whole manufacture process only involves fiber splicing and tapering, and all the fabrication process can be achieved by a commercial fiber fusion splicer. Using glycerol and water mixture solution as an example, the experimental results show that the refractive index sensitivity is measured to be 0.591 nm for 1% change of surrounding RI. The proposed sensor structure features simple structure, low cost, easy fabrication, and high sensitivity.

  6. Esthetic Outcomes of Immediately Loaded Locking Taper Implants in the Anterior Maxilla: A Case Series Study.

    Science.gov (United States)

    Lombardo, Giorgio; Corrocher, Giovanni; Pighi, Jacopo; Mascellaro, Anna; Marincola, Mauro; Nocini, Per Francesco

    2016-06-01

    The purpose of this study was to evaluate the esthetic outcome of single-tooth locking taper connection implants placed in the anterior maxilla following a postextractive nonfunctional loading protocol. This preliminary clinical study involving 16 patients evaluated the results of 21 implants placed in areas with high esthetic value. For each implant the pink esthetic score, white esthetic score, cumulative survival rate, and health status of peri-implant tissues were evaluated. The cumulative survival rate was 100% 2 years after prosthetic loading, and the mean total pink esthetic score/white esthetic score was 16.9 ± 1.14 on a maximum value of 20. There was excellent plaque control in all patients, and inflammation indices were within the norm. Within the limits of this study, this immediate nonfunctional loading protocol seems to be a successful procedure esthetically and for the maintenance of peri-implant soft tissues.

  7. Tapered Fiber Coated with Hydroxyethyl Cellulose/Polyvinylidene Fluoride Composite for Relative Humidity Sensor

    Directory of Open Access Journals (Sweden)

    M. Z. Muhammad

    2013-01-01

    Full Text Available A simple relative humidity (RH sensor is demonstrated using a tapered fiber coated with hydroxyethyl cellulose/polyvinylidene fluoride (HEC/PVDF composite as a probe. This coating acts as an inner cladding whose refractive index decreases with the rise in humidity and thus allows more light to be transmitted in humid state. A difference of up to 0.89 dB of the transmitted optical power is observed when RH changes from 50% to 80% in case of the silica fiber probe. The proposed sensor has a sensitivity of about 0.0228 dB/%RH with a slope linearity of more than 99.91%. In case of the plastic optical fiber (POF probe, the output voltage of the sensor increases linearly with a sensitivity of 0.0231 mV/%RH and a linearity of more than 99.65% as the relative humidity increases from 55% to 80%.

  8. Design Analysis of Taper Width Variations in Magnetless Linear Machine for Traction Applications

    Directory of Open Access Journals (Sweden)

    Saadha Aminath

    2018-01-01

    Full Text Available Linear motors are being used in a different application with a huge popularity in the use of transport industry. With the invention of maglev trains and other high-speed trains, linear motors are being used for the translation and braking applications for these systems. However, a huge drawback of the linear motor design is the cogging force, low thrust values, and voltage ripples. This paper aims to study the force analysis with change in taper/teeth width of the motor stator and mover to understand the best teeth ratio to obtain a high flux density and a high thrust. The analysis is conducted through JMAG software and it is found that the optimum teeth ratio for both the stator and mover gives an increase of 94.4% increases compared to the 0.5mm stator and mover width.

  9. Tapered oral dexamethasone for the acute chest syndrome of sickle cell disease

    Science.gov (United States)

    Quinn, Charles T.; Stuart, Marie J.; Kesler, Karen; Ataga, Kenneth I.; Wang, Winfred C.; Styles, Lori; Smith-Whitley, Kim; Wun, Ted; Raj, Ahsok; Hsu, Lewis L.; Krishnan, Suba; Kuypers, Frans A; Setty, B. N. Yamaja; Rhee, Seungshin; Key, Nigel S.; Buchanan, George R.

    2011-01-01

    Summary Tapered oral dexamethasone for acute chest syndrome (ACS) in sickle cell anaemia was studied using a novel ACS assessment tool and investigational biomarkers. Twelve participants were randomized (mean age 17.3 years) before early study termination. Dexamethasone decreased duration of hospitalization for ACS by 20.8 h compared to placebo (P=0.024). Rebound pain occurred in both groups (3 dexamethasone vs. 1 placebo). Overall, dexamethasone decreased the leucocyte activation biomarker, sL-selectin; however, participants with rebound pain had higher sL-selectin within 24 h of treatment (dexamethasone or placebo). This ACS assessment tool was feasibly applied, and sL-selectin is a promising biomarker of ACS therapy. PMID:21848879

  10. Power-efficient production of photon pairs in a tapered chalcogenide microwire

    Energy Technology Data Exchange (ETDEWEB)

    Meyer-Scott, Evan, E-mail: emeyersc@uwaterloo.ca; Dot, Audrey [Institute for Quantum Computing and Department of Physics and Astronomy, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1 (Canada); Ahmad, Raja; Li, Lizhu; Rochette, Martin [Department of Electrical and Computer Engineering, McGill University, 3480 University Street, Montréal, Québec H3A 2A7 (Canada); Jennewein, Thomas [Institute for Quantum Computing and Department of Physics and Astronomy, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1 (Canada); Quantum Information Science Program, Canadian Institute for Advanced Research, 180 Dundas Street West, Suite 1400, Toronto, Ontario M5G 1Z8 (Canada)

    2015-02-23

    Using tapered fibers of As{sub 2}Se{sub 3} chalcogenide glass, we produce photon pairs at telecommunication wavelengths with low pump powers. We found maximum coincidences-to-accidentals ratios of 2.13 ± 0.07 for degenerate pumping with 3.2 μW average power, and 1.33 ± 0.03 for non-degenerate pumping with 1.0 μW and 1.5 μW average power of the two pumps. Our results show that the ultrahigh nonlinearity in these microwires could allow single-photon pumping to produce photon pairs, enabling the production of large entangled states, heralding of single photons after lossy transmission, and photonic quantum information processing with nonlinear optics.

  11. Controllable pulse width of bright similaritons in a tapered graded index diffraction decreasing waveguide

    Energy Technology Data Exchange (ETDEWEB)

    Prakash, S. Arun [Department of EEE, Anna University, Ramanathapuram 623513 (India); Malathi, V. [Department of EEE, Anna University, Regional office, Madurai (India); Mani Rajan, M. S., E-mail: senthilmanirajanofc@gmail.com [Department of Physics, Anna University, Ramanathapuram 623513 (India); Loomba, Shally [Department of Physics, Panjab University, Chandigarh 160014 (India)

    2016-03-15

    We obtain the bright similariton solutions for generalized inhomogeneous nonlinear Schrödinger equation (GINLSE) which governs the pulse propagation in a tapered graded index diffraction decreasing waveguide (DDW). The exact solutions have been worked out by employing similarity transformations which involve the mapping of the GINLSE to standard NLSE for the certain conditions of the parameters. By making use of the exact analytical solutions, we have investigated the dynamical behavior of optical similariton pairs and have suggested the methods to control them as they propagate through DDW. Moreover, pulse width of similariton is controlled through various profiles. These results are helpful to understand the similaritons in DDW and can be potentially useful for future experiments in optical communications which involve optical amplifiers and long-haul telecommunication networks.

  12. Stereomicroscopic evaluation of dentinal defects induced by new rotary system: "ProTaper NEXT".

    Science.gov (United States)

    Shori, Deepa Deepak; Shenoi, Pratima Ramakrishna; Baig, Arshia R; Kubde, Rajesh; Makade, Chetana; Pandey, Swapnil

    2015-01-01

    The objective of this study was to evaluate dentinal defects formed by new rotary system - Protaper next™ (PTN). Sixty single-rooted premolars were selected. All specimens were decoronated and divided into four groups, each group having 15 specimens. Group I specimens were prepared by Hand K-files (Mani), Group II with ProTaper Universal (PT; Dentsply Maillefer), Group III with Hero Shaper (HS; Micro-Mega, Besancon, France), and Group IV with PTN (Dentsply Maillefer). Roots of each specimen were sectioned at 3, 6, and 9mm from the apex and were then viewed under a stereomicroscope to evaluate presence or absence of dentinal defects. In roots prepared with hand files (HFs) showed lowest percentage of dentinal defects (6.7%); whereas in roots prepared with PT, HS, and PTN it was 40, 66.7, and 26.7%, respectively. There was significant difference between the HS group and the PTN group (P hand instruments induced minimal defects.

  13. Mid-infrared fiber-coupled supercontinuum spectroscopic imaging using a tapered chalcogenide photonic crystal fiber

    Science.gov (United States)

    Rosenberg Petersen, Christian; Prtljaga, Nikola; Farries, Mark; Ward, Jon; Napier, Bruce; Lloyd, Gavin Rhys; Nallala, Jayakrupakar; Stone, Nick; Bang, Ole

    2018-02-01

    We present the first demonstration of mid-infrared spectroscopic imaging of human tissue using a fiber-coupled supercontinuum source spanning from 2-7.5 μm. The supercontinuum was generated in a tapered large mode area chalcogenide photonic crystal fiber in order to obtain broad bandwidth, high average power, and single-mode output for good imaging properties. Tissue imaging was demonstrated in transmission by raster scanning over a sub-mm region of paraffinized colon tissue on CaF2 substrate, and the signal was measured using a fiber-coupled grating spectrometer. This demonstration has shown that we can distinguish between epithelial and surrounding connective tissues within a paraffinized section of colon tissue by imaging at discrete wavelengths related to distinct chemical absorption features.

  14. Successful Use of Adalimumab for Treating Pyoderma Gangrenosum with Ulcerative Colitis under Corticosteroid-tapering Conditions.

    Science.gov (United States)

    Sagami, Shintaro; Ueno, Yoshitaka; Tanaka, Shinji; Nagai, Kenta; Hayashi, Ryohei; Chayama, Kazuaki

    2015-01-01

    A 52-year-old woman with ulcerative colitis was admitted to our hospital for an ulcerative colitis flare-up under salazosulfapyridine therapy. The symptoms improved with high-dose corticosteroids. After prednisolone was tapered to 10 mg, the frequency of diarrhea increased. The diarrhea was accompanied by joint pain and a skin ulcer with abscess formation, which was diagnosed to be pyoderma gangrenosum. The patient was started on adalimumab. A positive response to the adalimumab therapy was observed after 2 weeks, during which time the ulcerative skin lesion healed completely, however, colonic mucosal healing was achieved at 2 months. Therefore, adalimumab appears to be an effective therapeutic option for patients with ulcerative colitis-associated pyoderma gangrenosum.

  15. Magnetic Field Sensing Based on Bi-Tapered Optical Fibers Using Spectral Phase Analysis.

    Science.gov (United States)

    Herrera-Piad, Luis A; Haus, Joseph W; Jauregui-Vazquez, Daniel; Sierra-Hernandez, Juan M; Estudillo-Ayala, Julian M; Lopez-Dieguez, Yanelis; Rojas-Laguna, Roberto

    2017-10-20

    A compact, magnetic field sensor system based on a short, bi-tapered optical fiber (BTOF) span lying on a magnetic tape was designed, fabricated, and characterized. We monitored the transmission spectrum from a broadband light source, which displayed a strong interference signal. After data collection, we applied a phase analysis of the interference optical spectrum. We here report the results on two fabricated, BTOFs with different interference spectrum characteristics; we analyzed the signal based on the interference between a high-order modal component and the core fiber mode. The sensor exhibited a linear response for magnetic field increments, and we achieved a phase sensitivity of around 0.28 rad/mT. The sensing setup presented remote sensing operation and low-cost transducer magnetic material.

  16. Multi-cell disk-and-ring tapered structure for compact RF linacs

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, A.V.; Boucher, S.; Kutsaev, S. [RadiaBeam Systems LLC, 1713 Stewart Street, Santa Monica, CA 90404, US (United States); Hartzell, J. [RadiaBeam Technologies, LLC, 1717 Stewart Street, Santa Monica, CA 90404, US (United States); Savin, E. [RadiaBeam Technologies, LLC, 1717 Stewart Street, Santa Monica, CA 90404, US (United States); National Research Nuclear University “MEPhI”, Moscow 115409 (Russian Federation)

    2016-09-11

    A tubular disk-and-ring, tapered accelerating structure for small electron linacs and MicroLinacs is considered. It consists of metal and dielectric elements inserted into a metallic tube to eliminate multi-cell, multi-step brazing. The structure enables a wide range of phase velocities (including non-relativistic), a wide bandwidth allowing large number of cells (for standing wave mode) or short filling time (for traveling wave mode), combination of compensated and purely π-mode cells, alternative periodic focusing built-in to the RF structure (the disks), and combining of RF and vacuum windows. RF and accelerating performance of such a long structure having up to four dozens cells is analyzed. Some of beam dynamics, thermal, and vacuum aspects of the structure and MicroLinac performance are considered as well.

  17. Fabrication and Analysis of Tapered Tip Silicon Microneedles for MEMS based Drug Delivery System

    Directory of Open Access Journals (Sweden)

    Muhammad Waseem Ashraf

    2010-11-01

    Full Text Available In this paper, a novel design of transdermal drug delivery (TDD system is presented. The proposed system consists of controlled electronic circuit and microelectromechanical system (MEMS based devices like microneedles, micropump, flow sensor, and blood pressure sensor. The aim of this project is to develop a system that can eliminate the limitations associated with oral therapy. In this phase tapered tip silicon microneedles have been fabricated using inductively coupled plasma (ICP etching technology. Using ANSYS, simulation of microneedles has been conducted before the fabrication process to test the design suitability for TDD. More over multifield analysis of reservoir integrated with microneedle array using piezoelectric actuator has also been performed. The effects of frequency and voltage on actuator and fluid flow rate through 6×6 microneedle array have been investigated. This work provides envisage data to design suitable devices for TDD.

  18. Magnetic Field Sensing Based on Bi-Tapered Optical Fibers Using Spectral Phase Analysis

    Directory of Open Access Journals (Sweden)

    Luis A. Herrera-Piad

    2017-10-01

    Full Text Available A compact, magnetic field sensor system based on a short, bi-tapered optical fiber (BTOF span lying on a magnetic tape was designed, fabricated, and characterized. We monitored the transmission spectrum from a broadband light source, which displayed a strong interference signal. After data collection, we applied a phase analysis of the interference optical spectrum. We here report the results on two fabricated, BTOFs with different interference spectrum characteristics; we analyzed the signal based on the interference between a high-order modal component and the core fiber mode. The sensor exhibited a linear response for magnetic field increments, and we achieved a phase sensitivity of around 0.28 rad/mT. The sensing setup presented remote sensing operation and low-cost transducer magnetic material.

  19. Packaged silica microsphere-taper coupling system for robust thermal sensing application.

    Science.gov (United States)

    Yan, Ying-Zhan; Zou, Chang-Ling; Yan, Shu-Bin; Sun, Fang-Wen; Ji, Zhe; Liu, Jun; Zhang, Yu-Guang; Wang, Li; Xue, Chen-Yang; Zhang, Wen-Dong; Han, Zheng-Fu; Xiong, Ji-Jun

    2011-03-28

    We propose and realize a novel packaged microsphere-taper coupling structure (PMTCS) with a high quality factor (Q) up to 5×10(6) by using the low refractive index (RI) ultraviolet (UV) glue as the coating material. The optical loss of the PMTCS is analyzed experimentally and theoretically, which indicate that the Q is limited by the glue absorption and the radiation loss. Moreover, to verify the practicability of the PMTCS, thermal sensing experiments are carried out, showing the excellent convenience and anti-jamming ability of the PMTCS with a high temperature resolution of 1.1×10(-3) ◦C. The experiments also demonstrate that the PMTCS holds predominant advantages, such as the robustness, mobility, isolation, and the PMTCS can maintain the high Q for a long time. The above advantages make the PMTCS strikingly attractive and potential in the fiber-integrated sensors and laser.

  20. Multi-cell disk-and-ring tapered structure for compact RF linacs

    International Nuclear Information System (INIS)

    Smirnov, A.V.; Boucher, S.; Kutsaev, S.; Hartzell, J.; Savin, E.

    2016-01-01

    A tubular disk-and-ring, tapered accelerating structure for small electron linacs and MicroLinacs is considered. It consists of metal and dielectric elements inserted into a metallic tube to eliminate multi-cell, multi-step brazing. The structure enables a wide range of phase velocities (including non-relativistic), a wide bandwidth allowing large number of cells (for standing wave mode) or short filling time (for traveling wave mode), combination of compensated and purely π-mode cells, alternative periodic focusing built-in to the RF structure (the disks), and combining of RF and vacuum windows. RF and accelerating performance of such a long structure having up to four dozens cells is analyzed. Some of beam dynamics, thermal, and vacuum aspects of the structure and MicroLinac performance are considered as well.

  1. Tapered fiber coupling of single photons emitted by a deterministically positioned single nitrogen vacancy center

    Energy Technology Data Exchange (ETDEWEB)

    Liebermeister, Lars, E-mail: lars.liebermeister@physik.uni-muenchen.de; Petersen, Fabian; Münchow, Asmus v.; Burchardt, Daniel; Hermelbracht, Juliane; Tashima, Toshiyuki [Fakultät für Physik, Ludwig-Maximilians-Universität München, 80799 München (Germany); Schell, Andreas W.; Benson, Oliver [Institut für Physik, Humboldt-Universität zu Berlin, 12489 Berlin (Germany); Meinhardt, Thomas; Krueger, Anke [Institut für Organische Chemie, Universität Würzburg, 97074 Würzburg (Germany); Wilhelm Conrad Roentgen Research Center for Complex Materials Systems, Universität Würzburg, 97074 Würzburg (Germany); Stiebeiner, Ariane; Rauschenbeutel, Arno [Atominstitut, Technische Universität Wien, 1020 Wien (Austria); Weinfurter, Harald; Weber, Markus, E-mail: markusweber@lmu.de [Fakultät für Physik, Ludwig-Maximilians-Universität München, 80799 München (Germany); Max-Planck-Institut für Quantenoptik, 85748 Garching (Germany)

    2014-01-20

    A diamond nano-crystal hosting a single nitrogen vacancy (NV) center is optically selected with a confocal scanning microscope and positioned deterministically onto the subwavelength-diameter waist of a tapered optical fiber (TOF) with the help of an atomic force microscope. Based on this nano-manipulation technique, we experimentally demonstrate the evanescent coupling of single fluorescence photons emitted by a single NV-center to the guided mode of the TOF. By comparing photon count rates of the fiber-guided and the free-space modes and with the help of numerical finite-difference time domain simulations, we determine a lower and upper bound for the coupling efficiency of (9.5 ± 0.6)% and (10.4 ± 0.7)%, respectively. Our results are a promising starting point for future integration of single photon sources into photonic quantum networks and applications in quantum information science.

  2. Effect of the sterilization on the cutting efficiency of ProTaper® and K3® endodontic instruments

    Directory of Open Access Journals (Sweden)

    Alex Niederauer Becker

    2009-12-01

    Full Text Available Objective: This objective of this study was to evaluate the effect of sterilization on the cutting efficiency of rotary endodontic instruments, ProTaper® (Dentsply Maillefer Instruments S.A., Ballaigues, Suíça and K3® (Sybron/Kerr, Orange, CA, USA, by the time X weighing method. Method: For this purpose, 60 simulated canals and 66 instruments were used (36 of the ProTaper® system, (Dentsply Maillefer Instruments S.A., Ballaigues, Switzerland and 30 of the K3® system (Sybron/Kerr, Orange, CA, USA. The rotary instruments were divided into four experimental groups. The instruments in Group A (K3®, Sybron/Kerr, Orange, CA, USA and Group B (ProTaper®, Dentsply Maillefer Instruments S.A., Ballaigues, Switzerland, were subjected to a process of cleaning and sterilization. Whereas the instruments in Group C (K3®, Sybron/Kerr, Orange, CA, USA and Group D (ProTaper®, Dentsply Maillefer Instruments S.A., Ballaigues, Switzerland, were subjected to the cleanness process only, and were not sterilized. Results: As regards analysis of the results, the Student’s-t test was used, by which it was verified that the instruments in Group had greater cutting efficiency in comparison with those in Group B. Similarly the instruments in Group C had greater cutting efficiency in comparison with those in Group D, nevertheless, there was no statistically significant difference. Moreover, as regards the number times of use, there was also no statistically significant difference between the experimental groups. However in all the groups there was a decrease in the cutting efficiency with an increasing number of times of use. Conclusion: Thus, the cutting efficiency of rotary endodontic instruments K3® (Sybron/Kerr, Orange, CA, USA and ProTaper® (Dentsply Maillefer Instruments S.A., Ballaigues, Suição was not statistically affected after the use of 6 autoclave sterilization cycles.

  3. Energy consumption of ProTaper Next X1 after glide path with PathFiles and ProGlider.

    Science.gov (United States)

    Berutti, Elio; Alovisi, Mario; Pastorelli, Michele Angelo; Chiandussi, Giorgio; Scotti, Nicola; Pasqualini, Damiano

    2014-12-01

    Instrument failure caused by excessive torsional stress can be controlled by creating a manual or mechanical glide path. The ProGlider single-file system (Dentsply Maillefer, Ballaigues, Switzerland) was recently introduced to perform a mechanical glide path. This study was designed to compare the effect of a glide path performed with PathFiles (Dentsply Maillefer) and ProGlider on torque, time, and pecking motion required for ProTaper Next X1 (Dentsply Maillefer) to reach the full working length in simulated root canals. Forty Endo Training Blocks (Dentsply Maillefer) were used. Twenty were prepared with a mechanical glide path using PathFiles 1 and 2 (the PathFile group), and 20 were prepared with a mechanical glide path using a ProGlider single file (the ProGlider group). All samples were shaped with ProTaper Next X1 driven by an endodontic motor connected to a digital wattmeter. The required torque for root canal instrumentation was analyzed by evaluating the electrical power consumption of the endodontic engine. Electric power consumption (mW/h), elapsed time (seconds), and number of pecking motions required to reach the full working length with ProTaper Next X1 were calculated. Differences among groups were analyzed with the parametric Student t test for independent data (P < .05). Elapsed time and electric power consumption were significantly different between groups (P = .0001 for both). ProGlider appears to perform more efficiently than PathFiles in decreasing electric power consumption of ProTaper Next X1 to reach the full working length. This study confirmed the ability of ProGlider to reduce stress in ProTaper Next X1 during shaping through a glide path and preliminary middle and coronal preflaring. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. Effect of Taper on Stress Distribution of All Ceramic Fixed Partial Dentures: a 3D-FEA Study

    Directory of Open Access Journals (Sweden)

    F. Gerami-Panah

    2005-09-01

    Full Text Available Statement of Problem: Mechanical failure of ceramic materials is controlled by brittle fracture, mostly occurred in tension. In 3-unit all-ceramic FPDs the connector area is considered to be at fracture risk because of tensile stress concentrations.Purpose: The aim of this FE analysis was to evaluate the effect of taper on stress distribution in all-ceramic FPDs.Materials and Methods: In this experimental study two 3-D finite element models of thee-unit IPS-Empress 2 FPDs replacing mandible second premolar were created by means of finite element software. The digital images were obtained from CT scan of human skull. Abutment was reduced with 12 and 22 degrees of taper. The cement layer,PDL, cancellous bone and cortical bone were also modeled. Frameworks of core material were fabricated. A static load of 100 N was applied at mid pontic area.Resolved stresses were calculated according to the Von Mises criterion and principal stresses.Results: In both models stresses were concentrated at the connectors. The maximum stresses were lower in the model with larger taper. The maximum Von Mises stress was recorded at the connector region of the premolar and the pontic. In model with larger taper the patterns of stresses were also more distributed and less concentrated.Conclusion: The highest Von Mises and principal stress were recorded at the connectors. Tensile stresses developed at the gingival connector of premolar and pontic was higher than molar. The stress level in model with 22-degree taper was lower compare to 12-degree and the stress pattern was more distributed, lowered the risk ofconcentrations.

  5. Low-loss saturable absorbers based on tapered fibers embedded in carbon nanotube/polymer composites

    Science.gov (United States)

    Martinez, Amos; Al Araimi, Mohammed; Dmitriev, Artemiy; Lutsyk, Petro; Li, Shen; Mou, Chengbo; Rozhin, Alexey; Sumetsky, Misha; Turitsyn, Sergei

    2017-12-01

    The emergence of low-dimensional materials has opened new opportunities in the fabrication of compact nonlinear photonic devices. Single-walled carbon nanotubes were among the first of those materials to attract the attention of the photonics community owing to their high third order susceptibility, broadband operation, and ultrafast response. Saturable absorption, in particular, has become a widespread application for nanotubes in the mode-locking of a fiber laser where they are used as nonlinear passive amplitude modulators to initiate pulsed operation. Numerous approaches have been proposed for the integration of nanotubes in fiber systems; these can be divided into those that rely on direct interaction (where the nanotubes are sandwiched between fiber connectors) and those that rely on lateral interaction with the evanescence field of the propagating wave. Tapered fibers, in particular, offer excellent flexibility to adjust the nonlinearity of nanotube-based devices but suffer from high losses (typically exceeding 50%) and poor saturable to non-saturable absorption ratios (typically above 1:5). In this paper, we propose a method to fabricate carbon nanotube saturable absorbers with controllable saturation power, low-losses (as low as 15%), and large saturable to non-saturable loss ratios approaching 1:1. This is achieved by optimizing the procedure of embedding tapered fibers in low-refractive index polymers. In addition, this study sheds light in the operation of these devices, highlighting a trade-off between losses and saturation power and providing guidelines for the design of saturable absorbers according to their application.

  6. Low-loss saturable absorbers based on tapered fibers embedded in carbon nanotube/polymer composites

    Directory of Open Access Journals (Sweden)

    Amos Martinez

    2017-12-01

    Full Text Available The emergence of low-dimensional materials has opened new opportunities in the fabrication of compact nonlinear photonic devices. Single-walled carbon nanotubes were among the first of those materials to attract the attention of the photonics community owing to their high third order susceptibility, broadband operation, and ultrafast response. Saturable absorption, in particular, has become a widespread application for nanotubes in the mode-locking of a fiber laser where they are used as nonlinear passive amplitude modulators to initiate pulsed operation. Numerous approaches have been proposed for the integration of nanotubes in fiber systems; these can be divided into those that rely on direct interaction (where the nanotubes are sandwiched between fiber connectors and those that rely on lateral interaction with the evanescence field of the propagating wave. Tapered fibers, in particular, offer excellent flexibility to adjust the nonlinearity of nanotube-based devices but suffer from high losses (typically exceeding 50% and poor saturable to non-saturable absorption ratios (typically above 1:5. In this paper, we propose a method to fabricate carbon nanotube saturable absorbers with controllable saturation power, low-losses (as low as 15%, and large saturable to non-saturable loss ratios approaching 1:1. This is achieved by optimizing the procedure of embedding tapered fibers in low-refractive index polymers. In addition, this study sheds light in the operation of these devices, highlighting a trade-off between losses and saturation power and providing guidelines for the design of saturable absorbers according to their application.

  7. Comparative study of material loss at the taper interface in retrieved metal-on-polyethylene and metal-on-metal femoral components from a single manufacturer.

    Science.gov (United States)

    Bills, Paul; Racasan, Radu; Bhattacharya, Saugatta; Blunt, Liam; Isaac, Graham

    2017-08-01

    There have been a number of reports on the occurrence of taper corrosion and/or fretting and some have speculated on a link to the occurrence of adverse local tissue reaction specifically in relation to total hip replacement which have a metal-on-metal bearing. As such a study was carried out to compare the magnitude of material loss at the taper in a series of retrieved femoral heads used in metal-on-polyethylene bearings with that in a series of retrieved heads used in metal-on-metal bearings. A total of 36 metal-on-polyethylene and 21 metal-on-metal femoral components were included in the study all of which were received from a customer complaint database. Furthermore, a total of nine as-manufactured femoral components were included to provide a baseline for characterisation. All taper surfaces were assessed using an established corrosion scoring method and measurements were taken of the female taper surface using a contact profilometry. In the case of metal-on-metal components, the bearing wear was also assessed using coordinate metrology to determine whether or not there was a relationship between bearing and taper material loss in these cases. The study found that in this cohort the median value of metal-on-polyethylene taper loss was 1.25 mm 3 with the consequent median value for metal-on-metal taper loss being 1.75 mm 3 . This study also suggests that manufacturing form can result in an apparent loss of material from the taper surface determined to have a median value of 0.59 mm 3 . Therefore, it is clear that form variability is a significant confounding factor in the measurement of material loss from the tapers of femoral heads retrieved following revision surgery.

  8. Equações de volume e de taper para quantificar multiprodutos da madeira em Floresta Atlântica Volume and taper equations for wood multiproducts quantification in Floresta Atlantica-Brazil

    Directory of Open Access Journals (Sweden)

    José Franklin Chichorro

    2003-12-01

    Full Text Available Este estudo foi conduzido com o objetivo de ajustar uma equação de volume, a partir do modelo logaritmizado de Schumacher & Hall (1933, para estimar o volume comercial, e uma equação de afilamento (taper, a partir do modelo de Demaerschalk (1972, para estimar a quantidade de multiprodutos de madeira de espécies da Floresta Atlântica. Os dados foram coletados na Gleba C da Floresta Nacional do Rio Preto - IBAMA, no município de Conceição da Barra-ES. Foram mensuradas 165 árvores em pé, subdivididas em dez classes de diâmetro, com qualidade de fuste QF1 e pertencentes às espécies com maior VI e, ou, espécies de valor comercial. Essas árvores reuniram 62 espécies e 38 famílias. A equação de volume ajustou-se bem aos dados, com 2 igual a 0,9815 e resíduos normalmente distribuídos. A equação de taper também ajustou-se bem aos dados, com 2 igual a 0,9346 e distribuição gráfica dos resíduos normal. Pelo teste F (Graybill, 1976, constatou-se que houve igualdade entre os diâmetros observados e os diâmetros estimados pela equação de taper. A partir de transformações algébricas da equação de taper, foram estimados a altura para um determinado diâmetro superior d e o volume do tronco ou de parte dele. Em seguida, podem ser estimados o número de toras e o respectivo volume, em função do comprimento da tora, do diâmetro superior d mínimo e do uso desejado, o que permite avaliar a árvore em pé.This study was carried out to estimate a volume equation from a logarithmic model of Schumacher & Hall (1933 for comercial volume determination and a taper equation from the model of Demaerschalk (1972, to estimate wood multiproducts yield in Floresta Atlântica. Data were collected in Gleba C (C Glebe, with 289.5 hectares, owned by Floresta Nacional do Rio Preto (Rio Preto National Forest, under the administration of IBAMA, located in Conceição da Barra - Espírito Santo, Brazil. A total of 165 standing trees were measured

  9. Mega-bicone vacuum chamber for ISR intersections

    CERN Document Server

    CERN PhotoLab

    1975-01-01

    The cylindrical central part covered the collision region allowing secondary particles emitted at large angle to escape thanks to its very thin wall.The two conical parts are terminated by "transparent" thin windows for letting out forward emitted secondary particles. Vacuum chambers of this shape were made in their thin parts out of 0.3 mm stainless steel or 0.28 mm titanium alloy sheet. See also 7609219, 7609221, 7507132X.

  10. Multiwavelength mode-locked erbium-doped fiber laser based on the interaction of graphene and fiber-taper evanescent field

    International Nuclear Information System (INIS)

    Luo, Z Q; Wang, J Z; Zhou, M; Xu, H Y; Cai, Z P; Ye, C C

    2012-01-01

    We report on the generation of multiwavelength passively mode-locked pulses in an erbium-doped fiber laser (EDFL) based on the interaction of graphene and fiber-taper evanescent field. Graphene-polymer nanocomposites in aqueous suspension are trapped by the optical evanescent light and deposited on taper region. The graphene-deposited fiber-taper device not only acts as an excellent saturable absorber for mode-locking, but also induces a polarizing effect to form an artificial birefringent filter for multiwavelength selection. By simultaneously exploiting both functions of this device, four-wavelength continuous-wave mode-locking operation of an EDFL is stably initiated with a pulse width of 8.8 ps and a fundamental repetition rate of 8.034 MHz. This is the first time, to our knowledge, the mode-locked EDFL using such a new geometry of graphene-based tapered-fiber saturable absorber has been demonstrated

  11. Fatigue and Damage Tolerance Analysis of a Hybrid Composite Tapered Flexbeam

    Science.gov (United States)

    Murri, Gretchen B.; Schaff, Jeffrey R.; Dobyns, Al

    2001-01-01

    The behavior of nonlinear tapered composite flexbeams under combined axial tension and cyclic bending loading was studied using coupon test specimens and finite element (FE) analyses. The flexbeams used a hybrid material system of graphite/epoxy and glass/epoxy and had internal dropped plies, dropped in an overlapping stepwise pattern. Two material configurations, differing only in the use of glass or graphite plies in the continuous plies near the midplane, were studied. Test specimens were cut from a full-size helicopter tail-rotor flexbeam and were tested in a hydraulic load frame under combined constant axialtension load and transverse cyclic bending loads. The first determination damage observed in the specimens occurred at the area around the tip of the outermost ply-drop group in the tapered region of the flexbeam, near the thick end. Delaminations grew slowly and stably, toward the thick end of the flexbeam, at the interfaces above and below the dropped-ply region. A 2D finite element model of the flexbeam was developed. The model was analyzed using a geometrically non-linear analysis with both the ANSYS and ABAQUS FE codes. The global responses of each analysis agreed well with the test results. The ANSYS model was used to calculate strain energy release rates (G) for delaminations initiating at two different ply-ending locations. The results showed that delaminations were more inclined to grow at the locations where they were observed in the test specimens. Both ANSYS and ABAQUS were used to calculate G values associated with delamination initiating at the observed location but growing in different interfaces, either above or below the ply-ending group toward the thick end, or toward the thin end from the tip of the resin pocket. The different analysis codes generated the same trends and comparable peak values, within 5-11 % for each delamination path. Both codes showed that delamination toward the thick region was largely mode II, and toward the thin

  12. Effects of hole tapering on cone-beam collimation for brain SPECT imaging

    International Nuclear Information System (INIS)

    Park, Mi-Ae; Kijewski, Marie Foley; Moore, Stephen C.

    2006-01-01

    New collimator manufacturing technologies, such as photoetching, electrical discharge machining, and stereolithography, expand the range of possible cone-beam collimator configurations. For example, it might now be possible for brain SPECT to make a short-focusing cone-beam collimator with tapered holes that increase in size with distance from the collimator surface; conventional lead-casting techniques produce holes of constant size and, consequently, varying septal thicknesses. Moreover, the changes in hole shape and loss of close packing due to focusing leads to thicker septa in the collimator periphery, especially for shorter focal lengths. We investigated the potential advantages of new cone-beam collimator manufacturing processes, and proposed a new design for very short focal-length collimators for brain SPECT imaging. We compared three cone-beam collimators, a conventional collimator manufactured using casting techniques (CC), a novel collimator with uniform hole sizes on the collimator surface and constant hole size through the collimator thickness (FC), and a novel collimator with uniform hole sizes and tapered holes (TC). We determined the resolution of each collimator analytically for focal lengths ranging from 20-50 cm, and adjusted the entrance hole sizes of FC and TC to equalize resolution of all collimators. Sensitivity was calculated at several locations by Monte Carlo simulation. Sensitivity was higher at all points for TC and FC than for CC, and higher for TC than for FC. The differences in sensitivity were larger for shorter focal lengths. For a point on the focal line at 10 cm in front of the collimator entrance surface, the sensitivity gain for TC compared to CC was 7% and 45% for focal lengths of 50 and 20 cm, respectively. The sensitivity gain for a 20-cm focal length, compared to CC, averaged over all locations, was 44% for TC and 23% for FC. We have shown that the new collimator designs made possible by new manufacturing techniques will

  13. Refractive index and strain sensor based on twin-core fiber with a novel T-shaped taper

    Science.gov (United States)

    Zhang, Chuanbiao; Ning, Tigang; Li, Jing; Zheng, JingJing; Gao, Xuekai; Pei, Li

    2018-06-01

    A compact in-fiber Mach-Zehnder interferometer (MZI) based on twin-core fiber (TCF) with a novel T-shaped taper is proposed and demonstrated. The taper was firstly fabricated by a short section of TCF, and then spliced with a section of cleaved single mode fiber (SMF). When the light transmit into the TCF, multiple modes will be excited and will propagate within the TCF. In experiment, the proposed device had a maximum interferometric extinction ratio about 17 dB. And the refractive index (RI), strain, and temperature response properties of the sensor have been investigated, which show a relatively high RI, strain sensitivity and low temperature cross sensitivity. Hence, the sensor can be a suitable candidate in the biochemical and physical sensing applications. And due to its easy and controllable fabrication, the novel drawing technology can be applied to more multicore optical fibers.

  14. Investigation of the Electron Acceleration by a High-Power Laser and a Density-Tapered Mixed-Gas Cell

    Science.gov (United States)

    Kim, Jinju; Phung, Vanessa L. J.; Kim, Minseok; Hur, Min-Sup; Suk, Hyyong

    2017-10-01

    Plasma-based accelerators can generate about 1000 times stronger acceleration field compared with RF-based conventional accelerators, which can be done by high power laser and plasma. There are many issues in this research and one of them is development of a good plasma source for higher electron beam energy. For this purpose, we are investigating a special type of plasma source, which is a density-tapered gas cell with a mixed-gas for easy injection. By this type of special gas cell, we expect higher electron beam energies with easy injection in the wakefield. In this poster, some experimental results for electron beam generation with the density-tapered mixed-gas cell are presented. In addition to the experimental results, CFD (Computational-Fluid-Dynamics) and PIC (Particle-In-Cell) simulation results are also presented for comparison studies.

  15. High-Pressure Hot-Gas Self-Acting Floating Ring Shaft Seal for Liquid Rocket Turbopumps. [tapered bore seals

    Science.gov (United States)

    Burcham, R. E.; Diamond, W. A.

    1980-01-01

    Design analysis, detail design, fabrication, and experimental evaluation was performed on two self acting floating ring shaft seals for a rocket engine turbopump high pressure 24132500 n/sq m (3500 psig) hot gas 533 K 9500 F) high speed 3142 rad/sec (30000 rmp) turbine. The initial design used Rayleigh step hydrodynamic lift pads to assist in centering the seal ring with minimum rubbing contact. The final design used a convergent tapered bore to provide hydrostatic centering force. The Rayleigh step design was tested for 107 starts and 4.52 hours total. The leakage was satisfactory; however, the design was not acceptable due to excessive wear caused by inadequate centering force and failure of the sealing dam caused by erosion damage. The tapered bore design was tested for 370 starts and 15.93 hours total. Satisfactory performance for the required life of 7.5 hours per seal was successfully demonstrated.

  16. Particle-in-cell analysis of beam-wave interaction in gyrotron cavity with tapered magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, A., E-mail: anil.gyrotron@gmail.com [Gyrotron Lab., Microwave Tube Area, Central Electronics Engineering Research Inst. (CEERI, CSIR), Pilani, Rajasthan (India); Banasthali Univ., Dept. of Physics, Banasthali, Rajasthan (India); Khatun, H.; Kumar, N.; Singh, U.; Sinha, A.K. [Gyrotron Lab., Microwave Tube Area, Central Electronics Engineering Research Inst. (CEERI, CSIR), Pilani, Rajasthan (India); Vyas, V. [Banasthali Univ., Dept. of Physics, Banasthali, Rajasthan (India)

    2010-11-15

    A commercially available electromagnetic simulator -- MAGIC, a particle-in-cell (PIC) code -- has been used to carry out a comparative study of the beam-wave interaction under uniform and tapered magnetic field profiles of a 42 GHz, 200kW gyrotron. The magnetic field profile across the resonant cavity varies by ±6.5% with a peak value of 1.615 T. The MAGIC simulation shows the desire performance of the gyrotron under both magnetic field conditions with an operating mode TE{sub 03} and a pitch factor of 1.26. The analysis of the simulated results show that stability in the power growth was reached more quickly and achieved higher output power in the case of a tapered magnetic field. (author)

  17. Revision Total Hip Arthroplasty Using a Modular Tapered Stem With Distal Fixation Good Short-Term Results in 125 Revisions

    DEFF Research Database (Denmark)

    Ovesen, Ole; Emmeluth, Claus; Hofbauer, Christian

    2009-01-01

    After 2 to 7 years we reviewed 125 prosthetic hip arthroplasty stem revisions using a modular tapered stem with distal fixation. Median age of these patients was 68 (33-92) years. Baseline and follow-up data were registered prospectively according to the Danish Hip Arthroplasty Registry. Survival...... system is very versatile, can be used in most femoral revision cases, and allows rapid bone remodeling. We did not find an increased number of complications compared to the literature. Further long-term follow-up, however, is essential......., free of any rerevision, was 94%. Harris Hip Score improved from average 44 to 85. Bony regeneration was an early and significant finding in most cases. Complications included 4 (3%) fractures intraoperatively and 8 (6%) dislocations, 4 (3%) deep infections, and 1 (1%) stem fracture. This modular taper...

  18. High-temperature sensor based on an abrupt-taper Michelson interferometer in single-mode fiber.

    Science.gov (United States)

    Xu, Le; Jiang, Lan; Wang, Sumei; Li, Benye; Lu, Yongfeng

    2013-04-01

    This study proposes a high-temperature sensor based on an abrupt fiber-taper Michelson interferometer (FTMI) in single-mode fiber fabricated by a fiber-taper machine and electric-arc discharge. The proposed FTMI is applied to measure temperature and refractive index (RI). A high temperature sensitivity of 118.6 pm/°C is obtained in the temperature range of 500°C-800°C. The wavelength variation is only -0.335 nm for the maximum attenuation peak, with the external RI changed from 1.333 to 1.3902, which is desirable for high-temperature sensing to eliminate the cross sensitivity to RI.

  19. A high-average power tapered FEL amplifier at submillimeter frequencies using sheet electron beams and short-period wigglers

    International Nuclear Information System (INIS)

    Bidwell, S.W.; Radack, D.J.; Antonsen, T.M. Jr.; Booske, J.H.; Carmel, Y.; Destler, W.W.; Granatstein, V.L.; Levush, B.; Latham, P.E.; Zhang, Z.X.

    1990-01-01

    A high-average-power FEL amplifier operating at submillimeter frequencies is under development at the University of Maryland. Program goals are to produce a CW, ∼1 MW, FEL amplifier source at frequencies between 280 GHz and 560 GHz. To this end, a high-gain, high-efficiency, tapered FEL amplifier using a sheet electron beam and a short-period (superconducting) wiggler has been chosen. Development of this amplifier is progressing in three stages: (1) beam propagation through a long length (∼1 m) of short period (λ ω = 1 cm) wiggler, (2) demonstration of a proof-of-principle amplifier experiment at 98 GHz, and (3) designs of a superconducting tapered FEL amplifier meeting the ultimate design goal specifications. 17 refs., 1 fig., 1 tab

  20. Microtomography-based comparison of reciprocating single-file F2 ProTaper technique versus rotary full sequence

    OpenAIRE

    Paqué, F; Zehnder, Matthias; De-Deus, G

    2011-01-01

    Introduction A preparation technique with only 1 single instrument was proposed on the basis of the reciprocating movement of the F2 ProTaper instrument. The present study was designed to quantitatively assess canal preparation outcomes achieved by this technique. Methods Twenty-five extracted human mandibular first molars with 2 separate mesial root canals were selected. Canals were randomly assigned to 1 of the 2 experimental groups: group 1, rotary conventional preparation by us...

  1. The incidence of root microcracks caused by 3 different single-file systems versus the ProTaper system.

    Science.gov (United States)

    Liu, Rui; Hou, Ben Xiang; Wesselink, Paul R; Wu, Min-Kai; Shemesh, Hagay

    2013-08-01

    The aim of this study was to compare the incidence of root cracks observed at the apical root surface and/or in the canal wall after canal instrumentation with 3 single-file systems and the ProTaper system (Dentsply Maillefer, Ballaigues, Switzerland). One hundred mandibular incisors were selected. Twenty control teeth were coronally flared with Gates-Glidden drills (Dentsply Maillefer). No further preparation was made. The other 80 teeth were mounted in resin blocks with simulated periodontal ligaments, and the apex was exposed. They were divided into 4 experimental groups (n = 20); the root canals were first coronally flared with Gates-Glidden drills and then instrumented to the full working length with the ProTaper, OneShape (Micro-Mega, Besancon, France), Reciproc (VDW, Munich, Germany), or the Self-Adjusting File (ReDent-Nova, Ra'anana, Israel). The apical root surface and horizontal sections 2, 4, and 6 mm from the apex were observed under a microscope. The presence of cracks was noted. The chi-square test was performed to compare the appearance of cracked roots between the experimental groups. No cracks were found in the control teeth and teeth instrumented with the Self-Adjusting File. Cracks were found in 10 of 20 (50%), 7 of 20 (35%), and 1 of 20 (5%) teeth after canal instrumentation with the ProTaper, OneShape, and Reciproc files, respectively. The difference between the experimental groups was statistically significant (P File and Reciproc files caused less cracks than the ProTaper and OneShape files. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Comparison of the cleaning capacity of Mtwo and ProTaper rotary systems and manual instruments in primary teeth

    OpenAIRE

    Mohammad Reza Azar; Laya Safi; Afshin Nikaein

    2012-01-01

    Background: Root canal cleaning is an important step in endodontic therapy. In order to develop better techniques, a new generation of endodontic instruments has been designed. The aim of this study was to compare the effectiveness of manual K-files (Mani Co, Tokyo, Japan) and two rotary systems-Mtwo (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper (VDW, Munich, Germany)-for root canal preparation in primary molars. Materials and Methods: India ink was injected to 160 mesiobucca...

  3. Influence of radiation on MHD peristaltic blood flow through a tapered channel in presence of slip and joule heating

    Science.gov (United States)

    Ahamad, N. Ameer; Ravikumar, S.; Govindaraju, Kalimuthu

    2017-07-01

    The aim of the present attempt was to investigate an effect of slip and joule heating on MHD peristaltic Newtonian fluid through an asymmetric vertical tapered channel under influence of radiation. The Mathematical modeling is investigated by utilizing long wavelength and low Reynolds number assumptions. The effects of Hartmann number, porosity parameter, volumetric flow rate, radiation parameter, non uniform parameter, shift angle, Prandtl number, Brinkman number, heat source/sink parameter on temperature characteristics are presented graphically and discussed in detail.

  4. High-power dual-wavelength external-Cavity diode laser based on tapered amplifier with tunable terahertz frequency difference

    DEFF Research Database (Denmark)

    Chi, Mingjun; Jensen, Ole Bjarlin; Petersen, Paul Michael

    2011-01-01

    Tunable dual-wavelength operation of a diode laser system based on a tapered diode amplifier with double-Littrow external-cavity feedback is demonstrated around 800nm. The two wavelengths can be tuned individually, and the frequency difference of the two wavelengths is tunable from 0.5 to 5:0 THz......, this is the highest output power from a dual-wavelength diode laser system operating with tunable terahertz frequency difference. © 2011 Optical Society of America....

  5. Hand-operated and rotary ProTaper instruments: a comparison of working time and number of rotations in simulated root canals.

    Science.gov (United States)

    Pasqualini, Damiano; Scotti, Nicola; Tamagnone, Lorenzo; Ellena, Federica; Berutti, Elio

    2008-03-01

    The aim of this study was to compare the effective shaping time and number of rotations required by an endodontist working with hand and rotary ProTaper instruments to completely shape simulated root canals. Eighty Endo Training Blocks (curved canal shape) were used. Manual preflaring was performed with K-Flexofiles #08-10-12-15-17 and #20 Nitiflex at a working length of 18 mm. Specimens were then randomly assigned to 2 different groups (n = 40); group 1 was shaped by using hand ProTaper and group 2 with ProTaper rotary. The number of rotations made in the canal and the effective time required to achieve complete canal shaping were recorded for each instrument. Differences between groups were analyzed with the nonparametric Mann-Whitney U test (P Hand ProTaper required significantly fewer rotations (P ProTaper, whereas the effective working time to fully shape the simulated canal was significantly higher (P hand ProTaper.

  6. The efficacy of ProTaper Universal rotary retreatment instrumentation to remove single gutta-percha cones cemented with several endodontic sealers.

    Science.gov (United States)

    Ersev, H; Yilmaz, B; Dinçol, M E; Dağlaroğlu, R

    2012-08-01

    To evaluate residual root filling material following removal of three newly developed root canal sealers used with a matched-taper single-cone root filling technique and to compare the efficacy of ProTaper Universal rotary retreatment instruments with that of a conventional manual technique. The canals of 120 palatal roots in maxillary molar teeth were instrumented with EndoWave nickel-titanium rotary instruments and filled using Hybrid Root SEAL, EndoSequence BC Sealer, Activ GP system or AH Plus with matched-taper single gutta-percha cones. The root fillings were then removed with ProTaper Universal retreatment rotary instruments or a manual technique. Buccolingual and proximal digital radiographs of the roots were exposed to determine the area of remaining filling material in the coronal, middle and apical thirds. The area percentages of remaining filling material in each third and total canal area were calculated. Data were analysed statistically with Kruskal-Wallis and Mann-Whitney U-tests. The level of significance was set at PProTaper groups. When using gross radiographic criteria, the Activ GP was more effectively removed from root canals than AH Plus with hand instrumentation. Hybrid Root SEAL, EndoSequence BC Sealer and AH Plus were removed to a similar extent. ProTaper Universal retreatment instruments were as safe and effective as hand instruments in reaching the working length. © 2012 International Endodontic Journal.

  7. Effectiveness of ProTaper Universal retreatment instruments used with rotary or reciprocating adaptive motion in the removal of root canal filling material.

    Science.gov (United States)

    Capar, I D; Arslan, H; Ertas, H; Gök, T; Saygılı, G

    2015-01-01

    To compare the effectiveness of ProTaper Universal retreatment instruments with continuous rotation and adaptive motion (AM; a modified reciprocating motion that combines rotational and reciprocating motion) in the removal of filling material. Mesiobuccal root canals in 36 mandibular first molars were instrumented up to size F2 with the ProTaper Universal instrument (Dentsply Maillefer, Ballaigues, Switzerland) and filled using sealer and ProTaper Universal F2 gutta-percha cones. Gutta-percha was then down-packed and the root canal backfilled using the extruder hand-piece of the Elements Obturation System (SybronEndo, Orange, CA, USA). The teeth were assigned to two groups (n = 18), and removal of the root fillings was performed using one of the following techniques: group 1) ProTaper Universal retreatment files used with rotational motion (RM) and group 2) ProTaper Universal retreatment files used with adaptive motion (AM) (600° clockwise/0° counter-clockwise to 370° clockwise/50° counter-clockwise). The teeth were sectioned, and both halves were analysed at 8 × magnification. The percentage of remaining filling material was recorded. The data were analysed statistically using the Student's t-test at a 95% confidence level (P ProTaper Universal retreatment files with adaptive motion removed more filling materials from root canals than the rotational movement. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  8. Three-dimensional concentration of light in deeply sub-wavelength, laterally tapered gap-plasmon nanocavities

    Energy Technology Data Exchange (ETDEWEB)

    Tagliabue, Giulia [Laboratory of Thermodynamics in Emerging Technologies, ETH Zurich, Zurich 8092 (Switzerland); Thomas J. Watson, Sr. Laboratories of Applied Physics, California Institute of Technology, Pasadena, California 91125 (United States); Poulikakos, Dimos; Eghlidi, Hadi, E-mail: eghlidim@ethz.ch [Laboratory of Thermodynamics in Emerging Technologies, ETH Zurich, Zurich 8092 (Switzerland)

    2016-05-30

    Gap-plasmons (GP) in metal-insulator-metal (MIM) structures have shown exceptional performance in guiding and concentrating light within deep subwavelength layers. Reported designs to date exploit tapered thicknesses of the insulating layer in order to confine and focus the GP mode. Here, we propose a mechanism for the three dimensional concentration of light in planar MIM structures which exploits exclusively the lateral tapering of the front metallic layer while keeping a constant thickness of the insulating layer. We demonstrate that an array of tapered planar GP nanocavities can efficiently concentrate light in all three dimensions. A semi-analytical, one-dimensional model provides understanding of the underlying physics and approximately predicts the behavior of the structure. Three-dimensional simulations are then used to precisely calculate the optical behavior. Cavities with effective volumes as small as 10{sup −5} λ{sup 3} are achieved in an ultrathin MIM configuration. Our design is inherently capable of efficiently coupling with free-space radiation. In addition, being composed of two electrically continuous layers separated by an ultrathin dielectric spacer, it could find interesting applications in the area of active metamaterials or plasmonic photocatalysis where both electrical access and light concentration are required.

  9. Measurement and optimization of the light collection uniformity in strongly tapered PWO crystals of the PANDA detector

    Science.gov (United States)

    Diehl, Stefan; Bremer, Daniel; Brinkmann, Kai-Thomas; Dormenev, Valery; Eissner, Tobias; Novotny, Rainer W.; Rosenbaum, Christoph; Zaunick, Hans-Georg; PANDA Collaboration

    2017-06-01

    The uniformity of the light collection is a crucial parameter for detectors based on inorganic scintillation crystals to guarantee a response proportional to the deposited energy. Especially in case of tapered crystals, like they are widely used to realize a 4π geometry of electromagnetic calorimeters (EMC) in high energy physics experiments, a strong non-uniformity is introduced by an additional focusing of the scintillation light due to the tapered geometry. The paper will discuss the determination and the reduction of the non-uniformity in strongly tapered lead tungstate crystals as used for the construction of the electromagnetic calorimeter of the PANDA detector at the future Facility for Antiproton and Ion Research (FAIR). Among different concepts for an uniformization a single de-polished lateral side face provided the optimum result with a remaining non-uniformity below 5% in good agreement with similar studies for the CMS ECAL at LHC. The impact on the achievable energy resolution in the energy regime of photons below 800 MeV is discussed in detail in comparison to GEANT4 simulations. The comparison of the response of two arrays with polished and de-polished crystals, respectively, shows in the latter case a significant improvement of the constant term of the parametrization of the energy resolution down to 0.5% accompanied by only very slight increase of the statistical term.

  10. Influence of multiple clinical use on fatigue resistance of ProTaper rotary nickel-titanium instruments.

    Science.gov (United States)

    Vieira, E P; França, E C; Martins, R C; Buono, V T L; Bahia, M G A

    2008-02-01

    To examine the influence of clinical use on the occurrence of deformation and fracture and on the fatigue resistance of ProTaper rotary instruments. Root canal treatments were performed on patients using the ProTaper rotary system. Ten sets of instruments were used by an experienced endodontist, each set in five molars. Another 10 sets of instruments were used by the same operator, each set in eight molars. In addition, 10 sets of instruments were used, each set in five molars, by undergraduate students with no clinical experience with the system. After clinical use, S1, S2, F1 and F2 instruments were analysed for damage by optical and scanning electron microscopy. The used sets, along with a control group of 12 sets of new instruments, were then tested in a bench device for fatigue resistance. The use of the ProTaper rotary instruments by an experienced endodontist allowed for the cleaning and shaping of the root canal system of up to eight molars without fracture. During the students work, six instruments fractured. Fatigue resistance decreased upon clinical use for all instruments analysed. Fatigue resistance of used instruments was reduced, but no significant change was observed amongst the instruments used for shaping the canals of five and eight molars. Operator experience affected the occurrence of fracture and plastic deformation during shaping.

  11. Efficiency of the Self Adjusting File, WaveOne, Reciproc, ProTaper and hand files in root canal debridement.

    Science.gov (United States)

    Topcu, K Meltem; Karatas, Ertugrul; Ozsu, Damla; Ersoy, Ibrahim

    2014-07-01

    The aim of this study was to compare the canal debridement capabilities of three single file systems, ProTaper, and K-files in oval-shaped canals. Seventy-five extracted human mandibular central incisors with oval-shaped root canals were selected. A radiopaque contrast medium (Metapex; Meta Biomed Co. Ltd., Chungcheongbuk-do, Korea) was introduced into the canal systems and the self-adjusting file (SAF), WaveOne, Reciproc, ProTaper, and K-files were used for the instrumentation of the canals. The percentage of removed contrast medium was calculated using pre- and post-operative radiographs. An overall comparison between the groups revealed that the hand file (HF) and SAF groups presented the lowest percentage of removed contrast medium, whereas the WaveOne group showed the highest percentage (P ProTaper group removed more contrast medium than the SAF and HF groups (P < 0.05). None of the instruments was able to remove the contrast medium completely. WaveOne performed significantly better than other groups.

  12. Comparison of defects in ProTaper hand-operated and engine-driven instruments after clinical use.

    Science.gov (United States)

    Cheung, G S P; Bian, Z; Shen, Y; Peng, B; Darvell, B W

    2007-03-01

    To compare the type of defects and mode of material failure of engine-driven and hand-operated ProTaper instruments after clinical use. A total of 401 hand-operated and 325 engine-driven ProTaper instruments were discarded from an endodontic clinic over 17 months. Those that had fractured were examined for plastic deformation in lateral view and remounted for fractographical examination in scanning electron microscope. The mode of fracture was classified as 'fatigue' or 'shear' failure. The lengths of fractured segments in both instruments were recorded. Any distortion in hand instrument was noted. Data were analysed using chi-square, Fisher's exact or Student's t-test, where appropriate. Approximately 14% of all discarded hand-operated instruments and 14% of engine-driven instruments were fractured. About 62% of hand instruments failed because of shear fracture, compared with approximately 66% of engine-driven instruments as a result of fatigue (P hand instruments were affected by shear, and either remained intact or was fractured, compared with 5% of engine-driven instruments (P hand versus engine-driven group (P hand instruments were discarded intact but distorted (rarely for engine-driven instruments); all were in the form of unscrewing of the flutes. The location of defects in hand Finishing instruments was significantly closer to the tip than that for Shaping instruments (P ProTaper engine-driven and hand-operated instruments appeared to be different, with shear failure being more prevalent in the latter.

  13. Efficacy of ProTaper retreatment system in root canals filled with gutta-percha and two endodontic sealers.

    Science.gov (United States)

    Só, Marcus Vinícius Reis; Saran, Caroline; Magro, Miriam Lago; Vier-Pelisser, Fabiana Vieira; Munhoz, Marcelo

    2008-10-01

    This study evaluated the efficacy of ProTaper Universal rotary retreatment system and hand files for filling material removal during retreatment and the influence of sealer type on the presence of filling debris in the reinstrumented canals. The canals of 60 palatal roots of first molars were obturated with gutta-percha and either a zinc oxide-eugenol-based or a resin-based sealer and reinstrumented: G1, EndoFill/hand files; G2, AH Plus/hand files; G3, EndoFill/ProTaper; G4, AH Plus/ProTaper. Roots were cleaved and examined with an optical microscope, and the amount of filling debris on canal walls was analyzed on digitized images. There was no significant difference (P > .05) among the root canal thirds within each group. G3 presented significantly more filling debris than G1 in the cervical third (P = .04). In the middle third, G2/G3/G4 showed more debris than G1 (P = .03). The techniques were similar (P = .64) in the apical third. All groups presented filling debris in the 3 canal thirds after reinstrumentation.

  14. Experimental Measurement of the Static Coefficient of Friction at the Ti-Ti Taper Connection in Total Hip Arthroplasty.

    Science.gov (United States)

    Bitter, T; Khan, I; Marriott, T; Schreurs, B W; Verdonschot, N; Janssen, D

    2016-03-01

    The modular taper junction in total hip replacements has been implicated as a possible source of wear. The finite-element (FE) method can be used to study the wear potential at the taper junction. For such simulations it is important to implement representative contact parameters, in order to achieve accurate results. One of the main parameters in FE simulations is the coefficient of friction. However, in current literature, there is quite a wide spread in coefficient of friction values (0.15 - 0.8), which has a significant effect on the outcome of the FE simulations. Therefore, to obtain more accurate results, one should use a coefficient of friction that is determined for the specific material couple being analyzed. In this study, the static coefficient of friction was determined for two types of titanium-on-titanium stem-adaptor couples, using actual cut-outs of the final implants, to ensure that the coefficient of friction was determined consistently for the actual implant material and surface finish characteristics. Two types of tapers were examined, Biomet type-1 and 12/14, where type-1 has a polished surface finish and the 12/14 is a microgrooved system. We found static coefficients of friction of 0.19 and 0.29 for the 12/14 and type-1 stem-adaptor couples, respectively.

  15. Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System.

    Science.gov (United States)

    Hasheminia, Seyed Mohsen; Farhadi, Nastaran; Shokraneh, Ali

    2013-01-01

    The aim of this ex vivo study was to evaluate the effect of using a patency file on apical transportation and curve straightening during canal instrumentation with the ProTaper rotary system. Seventy permanent mandibular first molars with mesiobuccal canals, measuring 18-23 mm in length and with a 25-40° curvature (according to the Schneider method), were selected. The working lengths were determined and the teeth were mounted and divided into two experimental groups: (A) prepared by the ProTaper system without using a patency file (n = 35) and (B) prepared by the ProTaper system using a patency file (n = 35). Radiographs taken before and after the preparation were imported into Photoshop software and the apical transportation, and curve straightening were measured. Data were analyzed using independent t-test. Partial correlation analysis was performed to evaluate the relationship between the initial curvature, transportation, and curve straightening (α = 0.05). Using a patency file during canal preparation significantly decreased both apical transportation and curve straightening (P system.

  16. Design of electro-absorption modulator with tapered-mode coupler on the GeSi layer

    International Nuclear Information System (INIS)

    Li, Ym; Cheng, Bw

    2013-01-01

    A tapered-mode coupler integrated GeSi electro-absorption (EA) modulator is investigated theoretically. To improve the parameter insensitivity and modulation efficiency of the GeSi EA modulator based on evanescent coupling, a tapered coupler on the GeSi layer is introduced in our design. The two coupling mechanisms in our suggested structure are compared. Both the beam propagation method (BPM) calculation and coupling mode theory show almost 100% power transfer from the bottom rib waveguide to the GeSi layer. After a series of designs of the tapered coupler, we get a modulator with the advantages of both evanescent-coupling modulators (Feng et al 2011 Opt. Express 19 7062–7, Feng et al 2012 Opt. Express 20 22224–32, Liu et al 2008 Nature Photon. 2 433–7, Liu et al 2007 Opt. Express 15 623–8) and butt-coupling modulators (Lim et al 2011 Opt. Express 19 5040–6), that are ease of fabrication, low coupling loss, performance stability and high modulation efficiency. (paper)

  17. Canal shaping with WaveOne Primary reciprocating files and ProTaper system: a comparative study.

    Science.gov (United States)

    Berutti, Elio; Chiandussi, Giorgio; Paolino, Davide Salvatore; Scotti, Nicola; Cantatore, Giuseppe; Castellucci, Arnaldo; Pasqualini, Damiano

    2012-04-01

    This study compared the canal curvature and axis modification after instrumentation with WaveOne Primary reciprocating files (Dentsply Maillefer, Ballaigues, Switzerland) and nickel-titanium (NiTi) rotary ProTaper (Dentsply Maillefer). Thirty ISO 15, 0.02 taper, Endo Training Blocks (Dentsply Maillefer) were used. In all specimens, the glide path was achieved with PathFile 1, 2, and 3 (Dentsply Maillefer) at the working length (WL). Specimens were then assigned to 1 of 2 groups for shaping: specimens in group 1 were shaped with ProTaper S1-S2-F1-F2 at the WL and specimens in group 2 were shaped with WaveOne Primary reciprocating files at the WL. Pre- and postinstrumentation digital images were superimposed and processed with Matlab r2010b (The MathWorks Inc, Natick, MA) software to analyze the curvature-radius ratio (CRr) and the relative axis error (rAe), representing canal curvature modification. Data were analyzed with one-way balanced analyses of variance at 2 levels (P < .05). The instrument factor was extremely significant for both the CRr parameter (F(1) = 9.59, P = .004) and the rAe parameter (F(1) = 13.55, P = .001). Canal modifications are reduced when the new WaveOne NiTi single-file system is used. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Acrylic and metal based Y-branch plastic optical fiber splitter with optical NOA63 polymer waveguide taper region

    Science.gov (United States)

    Ehsan, Abang Annuar; Shaari, Sahbudin; Rahman, Mohd Kamil Abd.

    2011-01-01

    We proposed a simple low-cost acrylic and metal-based Y-branch plastic optical fiber (POF) splitter which utilizes a low cost optical polymer glue NOA63 as the main waveguiding medium at the waveguide taper region. The device is composed of three sections: an input POF waveguide, a middle waveguide taper region and output POF waveguides. A desktop high speed CNC engraver is utilized to produce the mold inserts used for the optical devices. Short POF fibers are inserted into the engraved slots at the input and output ports. UV curable optical polymer glue NOA63 is injected into the waveguide taper region and cured. The assembling is completed when the top plate is positioned to enclose the device structure and connecting screws are secured. Both POF splitters have an average insertion loss of 7.8 dB, coupling ratio of 55: 45 and 57: 43 for the acrylic and metal-based splitters respectively. The devices have excess loss of 4.82 and 4.73 dB for the acrylic and metal-based splitters respectively.

  19. Measurement and optimization of the light collection uniformity in strongly tapered PWO crystals of the PANDA detector

    Energy Technology Data Exchange (ETDEWEB)

    Diehl, Stefan; Bremer, Daniel; Brinkmann, Kai-Thomas; Dormenev, Valery; Eissner, Tobias; Novotny, Rainer W.; Rosenbaum, Christoph; Zaunick, Hans-Georg

    2017-06-11

    The uniformity of the light collection is a crucial parameter for detectors based on inorganic scintillation crystals to guarantee a response proportional to the deposited energy. Especially in case of tapered crystals, like they are widely used to realize a 4π geometry of electromagnetic calorimeters (EMC) in high energy physics experiments, a strong non-uniformity is introduced by an additional focusing of the scintillation light due to the tapered geometry. The paper will discuss the determination and the reduction of the non-uniformity in strongly tapered lead tungstate crystals as used for the construction of the electromagnetic calorimeter of the PANDA detector at the future Facility for Antiproton and Ion Research (FAIR). Among different concepts for an uniformization a single de-polished lateral side face provided the optimum result with a remaining non-uniformity below 5% in good agreement with similar studies for the CMS ECAL at LHC. The impact on the achievable energy resolution in the energy regime of photons below 800 MeV is discussed in detail in comparison to GEANT4 simulations. The comparison of the response of two arrays with polished and de-polished crystals, respectively, shows in the latter case a significant improvement of the constant term of the parametrization of the energy resolution down to 0.5% accompanied by only very slight increase of the statistical term.

  20. PENGEMBANGAN VARIATIF RANCANGAN ANTENA PANEL MICROSTRIP TAPERED PATCH DALAM SISTEM KOMUNIKASI WI-FI

    Directory of Open Access Journals (Sweden)

    Putu Artawan

    2013-04-01

    Full Text Available Pada penelitian ini dilakukan pengembangan rancangan antena microstrip tapered patch untuk dilakukan pengukuran parameternya sebagai karakteristik dari antena Microstrip. Penelitian ini sebagai pengembangan variatif rancangan untuk memperoleh hasil yang lebih optimal. Metode eksperiment dilakukan dalam penelitian ini. Tahap pengerjaanya yaitu membuat desain rancangan antena sesuai persamaan yang ada yang kemudian dirancang dengan metode UV Photoresist laminate. Hasil rancangan antena diukur untuk mendapatkan karakteristik sebagai parameter antena meliputi frekuensi (bandwidth, SWR, VSWR, koofesien refleksi, pola radiasi dan penguatan (gain serta nilai HPBW. Nilai-nilai tersebut mencerminkan karakter dari sebuah antena sebagai parameter antena yang layak diimplementasikan dalam sistem komunikasi internet dengan sistem wi-fi. Hasil penelitian ini meliputi: nilai lebar pita (bandwidth = 0.21 GHz, VSWR = 1,23, SWR = 1,79,  return loss = -20,00 dB, koofesien refleksi = 0,10 dan grafik pola radiasi dengan penguatan (gain = 17 dB (polarisasi vertikal, 20 dB (polarisasi horizontal. Nilai Half Power Beamwidth (HPBW 820 untuk pola radiasi vertikal dan pola radiasi horizontal. Kesalahan (error hasil pengukuran 0,12% dengan keseksamaan 99,88%. Hasil ini memberikan indikasi sebagai rancangan antena yang layak untuk sistem komunikasi wi-fi. Penelitian ini sebagai salah satu aplikasi ilmu Fisika dalam dunia teknologi informasi dan diharapkan dapat bermanfaat sebagai dinamika wahana salah satu produk penerapan ilmu Fisika dalam bidang Teknologi Informasi.