WorldWideScience

Sample records for interspin distance measurements

  1. Electron spin relaxation enhancement measurements of interspin distances in human, porcine, and Rhodobacter electron transfer flavoprotein ubiquinone oxidoreductase (ETF QO)

    Science.gov (United States)

    Fielding, Alistair J.; Usselman, Robert J.; Watmough, Nicholas; Simkovic, Martin; Frerman, Frank E.; Eaton, Gareth R.; Eaton, Sandra S.

    2008-02-01

    Electron transfer flavoprotein-ubiquinone oxidoreductase (ETF-QO) is a membrane-bound electron transfer protein that links primary flavoprotein dehydrogenases with the main respiratory chain. Human, porcine, and Rhodobacter sphaeroides ETF-QO each contain a single [4Fe-4S] 2+,1+ cluster and one equivalent of FAD, which are diamagnetic in the isolated enzyme and become paramagnetic on reduction with the enzymatic electron donor or with dithionite. The anionic flavin semiquinone can be reduced further to diamagnetic hydroquinone. The redox potentials for the three redox couples are so similar that it is not possible to poise the proteins in a state where both the [4Fe-4S] + cluster and the flavoquinone are fully in the paramagnetic form. Inversion recovery was used to measure the electron spin-lattice relaxation rates for the [4Fe-4S] + between 8 and 18 K and for semiquinone between 25 and 65 K. At higher temperatures the spin-lattice relaxation rates for the [4Fe-4S] + were calculated from the temperature-dependent contributions to the continuous wave linewidths. Although mixtures of the redox states are present, it was possible to analyze the enhancement of the electron spin relaxation of the FAD semiquinone signal due to dipolar interaction with the more rapidly relaxing [4Fe-4S] + and obtain point-dipole interspin distances of 18.6 ± 1 Å for the three proteins. The point-dipole distances are within experimental uncertainty of the value calculated based on the crystal structure of porcine ETF-QO when spin delocalization is taken into account. The results demonstrate that electron spin relaxation enhancement can be used to measure distances in redox poised proteins even when several redox states are present.

  2. Electron spin relaxation enhancement measurements of interspin distances in human, porcine, and Rhodobacter electron transfer flavoprotein-ubiquinone oxidoreductase (ETF-QO).

    Science.gov (United States)

    Fielding, Alistair J; Usselman, Robert J; Watmough, Nicholas; Simkovic, Martin; Frerman, Frank E; Eaton, Gareth R; Eaton, Sandra S

    2008-02-01

    Electron transfer flavoprotein-ubiquinone oxidoreductase (ETF-QO) is a membrane-bound electron transfer protein that links primary flavoprotein dehydrogenases with the main respiratory chain. Human, porcine, and Rhodobacter sphaeroides ETF-QO each contain a single [4Fe-4S](2+,1+) cluster and one equivalent of FAD, which are diamagnetic in the isolated enzyme and become paramagnetic on reduction with the enzymatic electron donor or with dithionite. The anionic flavin semiquinone can be reduced further to diamagnetic hydroquinone. The redox potentials for the three redox couples are so similar that it is not possible to poise the proteins in a state where both the [4Fe-4S](+) cluster and the flavoquinone are fully in the paramagnetic form. Inversion recovery was used to measure the electron spin-lattice relaxation rates for the [4Fe-4S](+) between 8 and 18K and for semiquinone between 25 and 65K. At higher temperatures the spin-lattice relaxation rates for the [4Fe-4S](+) were calculated from the temperature-dependent contributions to the continuous wave linewidths. Although mixtures of the redox states are present, it was possible to analyze the enhancement of the electron spin relaxation of the FAD semiquinone signal due to dipolar interaction with the more rapidly relaxing [4Fe-4S](+) and obtain point-dipole interspin distances of 18.6+/-1A for the three proteins. The point-dipole distances are within experimental uncertainty of the value calculated based on the crystal structure of porcine ETF-QO when spin delocalization is taken into account. The results demonstrate that electron spin relaxation enhancement can be used to measure distances in redox poised proteins even when several redox states are present.

  3. The efficacy of two electrodes radiofrequency technique: comparison study using a cadaveric interspinous ligament and temperature measurement using egg white.

    Science.gov (United States)

    Lee, Chang-Hyung; Derby, Richard; Choi, Hyun-Seok; Lee, Sang-Heon; Kim, Se Hoon; Kang, Yoon Kyu

    2010-01-01

    One technique in radiofrequency neurotomies uses 2 electrodes that are simultaneously placed to lie parallel to one another. Comparing lesions on cadaveric interspinous ligament tissue and measuring the temperature change in egg white allows us to accurately measure quantitatively the area of the lesion. Fresh cadaver spinal tissue and egg white tissue were used. A series of samples were prepared with the electrodes placed 1 to 7 mm apart. Using radiofrequency, the needle electrodes were heated in sequential or simultaneous order and the distance of the escaped lesion area and temperature were measured. Samples of cadaver interspinous ligament showed sequential heating of the needles limits the placement of the needle electrodes up to 2 mm apart from each other and up to 4 mm apart when heated simultaneously. The temperature at the escaped lesion area decreased according to the distance for egg white. There was a significant difference in temperature at the escaped lesion area up to 6 mm apart and the temperature was above 50 degrees celsius up to 5 mm in simultaneous lesion and 3 mm in the sequential lesion. The limitations of this study include cadaveric experimentation and use of intraspinous ligament rather than medial branch of the dorsal ramus which is difficult to identify. Heating the 2 electrodes simultaneously appears to coagulate a wider area and potentially produce better results in less time.

  4. Inter-spin distance determination using L-band (1-2 GHz) non-adiabatic rapid sweep electron paramagnetic resonance (NARS EPR)

    Science.gov (United States)

    Kittell, Aaron W.; Hustedt, Eric J.; Hyde, James S.

    2014-01-01

    Site-directed spin-labeling electron paramagnetic resonance (SDSL EPR) provides insight into the local structure and motion of a spin probe strategically attached to a molecule. When a second spin is introduced to the system, macromolecular information can be obtained through measurement of inter-spin distances either by continuous wave (CW) or pulsed electron double resonance (ELDOR) techniques. If both methodologies are considered, inter-spin distances of 8 to 80 Å can be experimentally determined. However, there exists a region at the upper limit of the conventional X-band (9.5 GHz) CW technique and the lower limit of the four-pulse double electron-electron resonance (DEER) experiment where neither method is particularly reliable. The work presented here utilizes L-band (1.9 GHz) in combination with non-adiabatic rapid sweep (NARS) EPR to address this opportunity by increasing the upper limit of the CW technique. Because L-band linewidths are three to seven times narrower than those at X-band, dipolar broadenings that are small relative to the X-band inhomogeneous linewidth become observable, but the signal loss due to the frequency dependence of the Boltzmann factor, has made L-band especially challenging. NARS has been shown to increase sensitivity by a factor of five, and overcomes much of this loss, making L-band distance determination more feasible [1]. Two different systems are presented and distances of 18–30 Å have been experimentally determined at physiologically relevant temperatures. Measurements are in excellent agreement with a helical model and values determined by DEER. PMID:22750251

  5. ORDERED WEIGHTED DISTANCE MEASURE

    Institute of Scientific and Technical Information of China (English)

    Zeshui XU; Jian CHEN

    2008-01-01

    The aim of this paper is to develop an ordered weighted distance (OWD) measure, which is thegeneralization of some widely used distance measures, including the normalized Hamming distance, the normalized Euclidean distance, the normalized geometric distance, the max distance, the median distance and the min distance, etc. Moreover, the ordered weighted averaging operator, the generalized ordered weighted aggregation operator, the ordered weighted geometric operator, the averaging operator, the geometric mean operator, the ordered weighted square root operator, the square root operator, the max operator, the median operator and the min operator axe also the special cases of the OWD measure. Some methods depending on the input arguments are given to determine the weights associated with the OWD measure. The prominent characteristic of the OWD measure is that it can relieve (or intensify) the influence of unduly large or unduly small deviations on the aggregation results by assigning them low (or high) weights. This desirable characteristic makes the OWD measure very suitable to be used in many actual fields, including group decision making, medical diagnosis, data mining, and pattern recognition, etc. Finally, based on the OWD measure, we develop a group decision making approach, and illustrate it with a numerical example.

  6. Electromagnetic distance measurement

    CERN Document Server

    1967-01-01

    This book brings together the work of forty-eight geodesists from twenty-five countries. They discuss various new electromagnetic distance measurement (EDM) instruments - among them the Tellurometer, Geodimeter, and air- and satellite-borne systems - and investigate the complex sources of error.

  7. Measuring distances between complex networks

    International Nuclear Information System (INIS)

    Andrade, Roberto F.S.; Miranda, Jose G.V.; Pinho, Suani T.R.; Lobao, Thierry Petit

    2008-01-01

    A previously introduced concept of higher order neighborhoods in complex networks, [R.F.S. Andrade, J.G.V. Miranda, T.P. Lobao, Phys. Rev. E 73 (2006) 046101] is used to define a distance between networks with the same number of nodes. With such measure, expressed in terms of the matrix elements of the neighborhood matrices of each network, it is possible to compare, in a quantitative way, how far apart in the space of neighborhood matrices two networks are. The distance between these matrices depends on both the network topologies and the adopted node numberings. While the numbering of one network is fixed, a Monte Carlo algorithm is used to find the best numbering of the other network, in the sense that it minimizes the distance between the matrices. The minimal value found for the distance reflects differences in the neighborhood structures of the two networks that arise only from distinct topologies. This procedure ends up by providing a projection of the first network on the pattern of the second one. Examples are worked out allowing for a quantitative comparison for distances among distinct networks, as well as among distinct realizations of random networks

  8. EFFECTS OF X-RAY BEAM ANGLE AND GEOMETRIC DISTORTION ON WIDTH OF EQUINE THORACOLUMBAR INTERSPINOUS SPACES USING RADIOGRAPHY AND COMPUTED TOMOGRAPHY

    DEFF Research Database (Denmark)

    Djernaes, Julie D.; Nielsen, Jon V.; Berg, Lise C.

    2017-01-01

    The widths of spaces between the thoracolumbar processi spinosi (interspinous spaces) are frequently assessed using radiography in sports horses; however effects of varying X-ray beam angles and geometric distortion have not been previously described. The aim of this prospective, observational...... study was to determine whether X-ray beam angle has an effect on apparent widths of interspinous spaces. Thoracolumbar spine specimens were collected from six equine cadavers and left-right lateral radiographs and sagittal and dorsal reconstructed computed tomographic (CT) images were acquired...... measurements. Effect of geometric distortion was evaluated by comparing the interspinous space in radiographs with sagittal and dorsal reconstructed CT images. A total of 49 interspinous spaces were sampled, yielding 274 measurements. X-ray beam angle significantly affected measured width of interspinous...

  9. Distance Measurement Solves Astrophysical Mysteries

    Science.gov (United States)

    2003-08-01

    Location, location, and location. The old real-estate adage about what's really important proved applicable to astrophysics as astronomers used the sharp radio "vision" of the National Science Foundation's Very Long Baseline Array (VLBA) to pinpoint the distance to a pulsar. Their accurate distance measurement then resolved a dispute over the pulsar's birthplace, allowed the astronomers to determine the size of its neutron star and possibly solve a mystery about cosmic rays. "Getting an accurate distance to this pulsar gave us a real bonanza," said Walter Brisken, of the National Radio Astronomy Observatory (NRAO) in Socorro, NM. Monogem Ring The Monogem Ring, in X-Ray Image by ROSAT satellite CREDIT: Max-Planck Institute, American Astronomical Society (Click on Image for Larger Version) The pulsar, called PSR B0656+14, is in the constellation Gemini, and appears to be near the center of a circular supernova remnant that straddles Gemini and its neighboring constellation, Monoceros, and is thus called the Monogem Ring. Since pulsars are superdense, spinning neutron stars left over when a massive star explodes as a supernova, it was logical to assume that the Monogem Ring, the shell of debris from a supernova explosion, was the remnant of the blast that created the pulsar. However, astronomers using indirect methods of determining the distance to the pulsar had concluded that it was nearly 2500 light-years from Earth. On the other hand, the supernova remnant was determined to be only about 1000 light-years from Earth. It seemed unlikely that the two were related, but instead appeared nearby in the sky purely by a chance juxtaposition. Brisken and his colleagues used the VLBA to make precise measurements of the sky position of PSR B0656+14 from 2000 to 2002. They were able to detect the slight offset in the object's apparent position when viewed from opposite sides of Earth's orbit around the Sun. This effect, called parallax, provides a direct measurement of

  10. Distance and Cable Length Measurement System

    Science.gov (United States)

    Hernández, Sergio Elias; Acosta, Leopoldo; Toledo, Jonay

    2009-01-01

    A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement. PMID:22303169

  11. Lumbar interspinous bursitis in active polymyalgia rheumatica.

    Science.gov (United States)

    Salvarani, Carlo; Barozzi, Libero; Boiardi, Luigi; Pipitone, Nicolò; Bajocchi, Gian Luigi; Macchioni, Pier Luigi; Catanoso, Mariagrazia; Pazzola, Giulia; Valentino, Massimo; De Luca, Carlo; Hunder, Gene G

    2013-01-01

    To evaluate the inflammatory involvement of lumbar interspinous bursae in patients with polymyalgia rheumatica (PMR) using magnetic resonance imaging (MRI). Ten consecutive, untreated new patients with PMR and pain in the shoulder and pelvic girdles were investigated. Seven patients with spondyloarthritis (4 with psoriatic spondyloarthrits, one with entheropatic spondyloarthritis, and 2 with ankylosing spondylitis) as well as 2 patients with spinal osteoarthritis and 2 patients with rheumatoid arthritis with lumbar pain served as controls. MRI of lumbar spine was performed in all PMR patients and controls. Nine patients (5 PMR patients and 4 controls) also had MRI of the thoracic spine. MRI evidence of interspinous lumbar bursitis was found in 9/10 patients with PMR and in 5/11 controls. A moderate to marked (grade ≥2 on a semiquantitative 0-3 scale) lumbar bursitis occurred significantly more frequently in patients with PMR than in control patients (60% vs. 9%, p=0.020). In most of the patients and controls lumbar bursitis was found at the L3-L5 interspaces. Only 2 patients had bursitis at a different level (one patient had widespread lumbar bursitis, and one control at L2-L4). No interspinous bursitis was demonstrated by MRI of the thoracic spine in patients and controls. Inflammation of lumbar bursae may be responsible for the low back pain reported by patients with PMR. The prominent inflammatory involvement of bursae including those of the lumbar spine supports the hypothesis that PMR may be a disorder affecting predominantly extra-articular synovial structures.

  12. Method of measuring distance between fuel element

    International Nuclear Information System (INIS)

    Urata, Megumu.

    1991-01-01

    The distance between fuel elements contained in a pool is measured in a contactless manner even for a narrow distance less than 1 mm. That is, the equipment for measuring the distance between spent fuel elements of a spent fuel assembly in a nuclear reactor comprises a optical fiber scope, a lens, an industrial TV camera and a monitor TV. The top end of the optical fiber scope is inserted between fuel elements to be measured. The state thereof is displayed on the TV screen to measure the distance between the fuel elements. The measured results are compared with a previously formed calibration curve to determine the value between the fuel elements. Then, the distance between the fuel elements can be determined in the pool of a power plant without dismantling the fuel assembly, to investigate the state of the bending and estimate the fuel working life. (I.S.)

  13. Electronic distance measurement: an introduction

    National Research Council Canada - National Science Library

    Rüeger, J. M

    1990-01-01

    .... It is excellently suited as a text for undergraduate and graduate students and as an invaluable reference for practicing surveyors, geodesists and other scientists using EDM as a measuring tool...

  14. A Novel Method for Short Distance Measurements

    International Nuclear Information System (INIS)

    Fernandez, M.G.; Ferrando, A.; Josa, M.I.; Molinero, A.; Oller, J.C.; Arce, P.; Calvo, E.; Figueroa, C.F.; Garcia, C.F.; Rodigrido, T.; Vila, I.; Virto, A.L.

    1998-01-01

    A new, accurate and un expensive device for measuring short distances, intended for monitoring in LHC experiments is presented. Data taken with a very simple prototype are shown and performance is extracted. (Author) 4 refs

  15. A cognitively grounded measure of pronunciation distance.

    Directory of Open Access Journals (Sweden)

    Martijn Wieling

    Full Text Available In this study we develop pronunciation distances based on naive discriminative learning (NDL. Measures of pronunciation distance are used in several subfields of linguistics, including psycholinguistics, dialectology and typology. In contrast to the commonly used Levenshtein algorithm, NDL is grounded in cognitive theory of competitive reinforcement learning and is able to generate asymmetrical pronunciation distances. In a first study, we validated the NDL-based pronunciation distances by comparing them to a large set of native-likeness ratings given by native American English speakers when presented with accented English speech. In a second study, the NDL-based pronunciation distances were validated on the basis of perceptual dialect distances of Norwegian speakers. Results indicated that the NDL-based pronunciation distances matched perceptual distances reasonably well with correlations ranging between 0.7 and 0.8. While the correlations were comparable to those obtained using the Levenshtein distance, the NDL-based approach is more flexible as it is also able to incorporate acoustic information other than sound segments.

  16. A Distance Measure for Genome Phylogenetic Analysis

    Science.gov (United States)

    Cao, Minh Duc; Allison, Lloyd; Dix, Trevor

    Phylogenetic analyses of species based on single genes or parts of the genomes are often inconsistent because of factors such as variable rates of evolution and horizontal gene transfer. The availability of more and more sequenced genomes allows phylogeny construction from complete genomes that is less sensitive to such inconsistency. For such long sequences, construction methods like maximum parsimony and maximum likelihood are often not possible due to their intensive computational requirement. Another class of tree construction methods, namely distance-based methods, require a measure of distances between any two genomes. Some measures such as evolutionary edit distance of gene order and gene content are computational expensive or do not perform well when the gene content of the organisms are similar. This study presents an information theoretic measure of genetic distances between genomes based on the biological compression algorithm expert model. We demonstrate that our distance measure can be applied to reconstruct the consensus phylogenetic tree of a number of Plasmodium parasites from their genomes, the statistical bias of which would mislead conventional analysis methods. Our approach is also used to successfully construct a plausible evolutionary tree for the γ-Proteobacteria group whose genomes are known to contain many horizontally transferred genes.

  17. How to measure distance visual acuity

    Directory of Open Access Journals (Sweden)

    Janet Marsden

    2014-04-01

    Full Text Available Visual acuity (VA is a measure of the ability of the eye to distinguish shapes and the details of objects at a given distance. It is important to assess VA in a consistent way in order to detect any changes in vision. One eye is tested at a time.

  18. Distance Measures for Information System Reengineering

    NARCIS (Netherlands)

    Poels, G.; Viaene, S.; Dedene, G.; Wangler, B.; Bergman, L.

    2000-01-01

    We present an approach to assess the magnitude and impact of information system reengineering caused by business process change. This approach is based on two concepts: object-oriented business modeling and distance measurement. The former concept is used to visualize changes in the business layer

  19. An Introduction to Distance Measurement in Astronomy

    CERN Document Server

    de Grijs, Richard

    2011-01-01

    Distance determination is an essential technique in astronomy, and is briefly covered in most textbooks on astrophysics and cosmology. It is rarely covered as a coherent topic in its own right. When it is discussed the approach is frequently very dry, splitting the teaching into, for example, stars, galaxies and cosmologies, and as a consequence, books lack depth and are rarely comprehensive. Adopting a unique and engaging approach to the subject An Introduction to distance Measurement in Astronomy will take the reader on a journey from the solar neighbourhood to the edge of the Universe, dis

  20. Shape anisotropy: tensor distance to anisotropy measure

    Science.gov (United States)

    Weldeselassie, Yonas T.; El-Hilo, Saba; Atkins, M. S.

    2011-03-01

    Fractional anisotropy, defined as the distance of a diffusion tensor from its closest isotropic tensor, has been extensively studied as quantitative anisotropy measure for diffusion tensor magnetic resonance images (DT-MRI). It has been used to reveal the white matter profile of brain images, as guiding feature for seeding and stopping in fiber tractography and for the diagnosis and assessment of degenerative brain diseases. Despite its extensive use in DT-MRI community, however, not much attention has been given to the mathematical correctness of its derivation from diffusion tensors which is achieved using Euclidean dot product in 9D space. But, recent progress in DT-MRI has shown that the space of diffusion tensors does not form a Euclidean vector space and thus Euclidean dot product is not appropriate for tensors. In this paper, we propose a novel and robust rotationally invariant diffusion anisotropy measure derived using the recently proposed Log-Euclidean and J-divergence tensor distance measures. An interesting finding of our work is that given a diffusion tensor, its closest isotropic tensor is different for different tensor distance metrics used. We demonstrate qualitatively that our new anisotropy measure reveals superior white matter profile of DT-MR brain images and analytically show that it has a higher signal to noise ratio than fractional anisotropy.

  1. Measures of lexical distance between languages

    Science.gov (United States)

    Petroni, Filippo; Serva, Maurizio

    2010-06-01

    The idea of measuring distance between languages seems to have its roots in the work of the French explorer Dumont D’Urville (1832) [13]. He collected comparative word lists for various languages during his voyages aboard the Astrolabe from 1826 to 1829 and, in his work concerning the geographical division of the Pacific, he proposed a method for measuring the degree of relation among languages. The method used by modern glottochronology, developed by Morris Swadesh in the 1950s, measures distances from the percentage of shared cognates, which are words with a common historical origin. Recently, we proposed a new automated method which uses the normalized Levenshtein distances among words with the same meaning and averages on the words contained in a list. Recently another group of scholars, Bakker et al. (2009) [8] and Holman et al. (2008) [9], proposed a refined version of our definition including a second normalization. In this paper we compare the information content of our definition with the refined version in order to decide which of the two can be applied with greater success to resolve relationships among languages.

  2. Metrics for measuring distances in configuration spaces

    International Nuclear Information System (INIS)

    Sadeghi, Ali; Ghasemi, S. Alireza; Schaefer, Bastian; Mohr, Stephan; Goedecker, Stefan; Lill, Markus A.

    2013-01-01

    In order to characterize molecular structures we introduce configurational fingerprint vectors which are counterparts of quantities used experimentally to identify structures. The Euclidean distance between the configurational fingerprint vectors satisfies the properties of a metric and can therefore safely be used to measure dissimilarities between configurations in the high dimensional configuration space. In particular we show that these metrics are a perfect and computationally cheap replacement for the root-mean-square distance (RMSD) when one has to decide whether two noise contaminated configurations are identical or not. We introduce a Monte Carlo approach to obtain the global minimum of the RMSD between configurations, which is obtained from a global minimization over all translations, rotations, and permutations of atomic indices

  3. Correlação da aferição manual e digital da distância interespinhosa pelo método de newmann em fraturas toracolombares do tipo explosão Correlación entre calibrado manual y digital de la distancia interespinhosa por el método de neumann en fracturas toracolombares tipo explosión Correlation between manual and digital measurement of inter-spinous dis tance by neumann method in burst thoracolumbar fracture

    Directory of Open Access Journals (Sweden)

    João Paulo Machado Bergamaschi

    2011-01-01

    Full Text Available OBJETIVO: Analisar a correlação entre a aferição manual e digital da distância interespinhosa pelo método de Neumann em fraturas toracolombares do tipo explosão, bem como a reprodutibilidade das duas técnicas. MÉTODOS: Foram avaliadas 212 radiografias de pacientes com fratura toracolombar do tipo explosão, sendo 160 do sexo masculino e 52 do sexo feminino. A idade média dos pacientes no tempo da fratura foi de 38,9 anos (variando de 12 a 76 anos. RESULTADOS: O coeficiente de Pearson, quando comparados os valores percentuais manuais e digitais da relação da distância interespinhosa do nível da vértebra fraturada e dos níveis adjacentes, foi de 0,95 (pOBJETIVO: El objetivo de este estudio es analizar la correlación entre calibrado manual y digital de la distancia interespinhosa por el método de Neumann en fracturas toracolombares tipo explosión, así como la reproducibilidad de los dos técnicas. MÉTODOS: Radiografías fueron evaluados 212 pacientes con fractura toracolombar tipo explosión, 160 hombres y 52 mujeres. La edad promedio de los pacientes en el momento de fractura fue 38.9 años (que van desde 12 a 76 años. RESULTADOS: El coeficiente de Pearson, cuando se comparan valores porcentuales digital y manuales de la relación de distancia interespinhosa el nivel de la vértebra fraturada y niveles adyacentes, fue 0.95 (pOBJECTIVE: The aim of this study is to analyze the correlation between the manual and digital inter-spinous distance by the Neumann method in burst thoracolumbar fracture, as well as the reproducibility of these two techniques. METHODS: We evaluated 212 x-rays of patients with burst thoracolumbar fracture. There were 60 male and 52 female. The average age at the time of the fracture was 38,9 years (12 - 76 years. RESULTS: The Pearson' coefficient between manual and digital analyses was 0,95 (p<0,01. The agreement coefficient of manual and digital measurements was 0,97 and 0,93, respectively. CONCLUSION

  4. Measuring sidewalk distances using Google Earth

    Directory of Open Access Journals (Sweden)

    Janssen Ian

    2012-03-01

    Full Text Available Abstract Background Physical activity is an important determinant of health. Walking is the most common physical activity performed by adults and the presence of sidewalks along roads is a determinant of walking. Geographic information systems (GIS can be used to measure sidewalks; however, GIS sidewalk data are difficult to access. The purpose of this study was to present a new GIS method for measuring the distance and coverage of sidewalks along roadways. Methods The new method contains three stages. Stage 1 involves calculating the distance of all road segments within the region of interest (e.g., neighborhood, extracting geospatial information on these road segments, and saving this information as a Google Earth file. This stage was performed in ArcGIS software. Stage 2 involves opening the extracted road segment geospatial data in Google Earth, visually examining road segments to see if they contain sidewalks, and deleting road segments without sidewalks. Stage 3 involves importing the modified road geospatial data into ArcGIS and calculating the length of road segments with sidewalks. The new method was tested in 315 sites across Canada. Each site consisted of a one km radius circular buffer surrounding a school. Results A detailed, step-by-step protocol is provided in the paper. The length of road segments with sidewalks in the testing sites ranged from 0.00 to 55.05 km (median 16.20 km. When expressed relative to the length of all road segments, the length of road segments with sidewalks ranged from 0% to 100% (median 53%. By comparison to urban testing sites, rural sites had shorter sidewalk lengths and a smaller proportion of the roads had sidewalk coverage. Conclusion This study provides a new GIS protocol that researchers can use to measure the distance and coverage of sidewalks along roadways.

  5. Improvement of Ultrasonic Distance Measuring System

    Directory of Open Access Journals (Sweden)

    Jiang Yu

    2018-01-01

    Full Text Available This paper mainly introduces a kind of ultrasonic distance measuring system with AT89C51 single chip as the core component. The paper expounds the principle of ultrasonic sensor and ultrasonic ranging, hardware circuit and software program, and the results of experiment and analysis.The hardware circuit based on SCM, the software design adopts the advanced microcontroller programming language.The amplitude of the received signal and the time of ultrasonic propagation are regulated by closed loop control. [1,2]The double closed loop control technology for amplitude and time improves the measuring accuracy of the instrument. The experimental results show that greatly improves the measurement accuracy of the system.

  6. Heterogeneity Measurement Based on Distance Measure for Polarimetric SAR Data

    Science.gov (United States)

    Xing, Xiaoli; Chen, Qihao; Liu, Xiuguo

    2018-04-01

    To effectively test the scene heterogeneity for polarimetric synthetic aperture radar (PolSAR) data, in this paper, the distance measure is introduced by utilizing the similarity between the sample and pixels. Moreover, given the influence of the distribution and modeling texture, the K distance measure is deduced according to the Wishart distance measure. Specifically, the average of the pixels in the local window replaces the class center coherency or covariance matrix. The Wishart and K distance measure are calculated between the average matrix and the pixels. Then, the ratio of the standard deviation to the mean is established for the Wishart and K distance measure, and the two features are defined and applied to reflect the complexity of the scene. The proposed heterogeneity measure is proceeded by integrating the two features using the Pauli basis. The experiments conducted on the single-look and multilook PolSAR data demonstrate the effectiveness of the proposed method for the detection of the scene heterogeneity.

  7. Measuring and testing dependence by correlation of distances

    OpenAIRE

    Székely, Gábor J.; Rizzo, Maria L.; Bakirov, Nail K.

    2007-01-01

    Distance correlation is a new measure of dependence between random vectors. Distance covariance and distance correlation are analogous to product-moment covariance and correlation, but unlike the classical definition of correlation, distance correlation is zero only if the random vectors are independent. The empirical distance dependence measures are based on certain Euclidean distances between sample elements rather than sample moments, yet have a compact representation analogous to the clas...

  8. Evaluation of Distance Measures Between Gaussian Mixture Models of MFCCs

    DEFF Research Database (Denmark)

    Jensen, Jesper Højvang; Ellis, Dan P. W.; Christensen, Mads Græsbøll

    2007-01-01

    In music similarity and in the related task of genre classification, a distance measure between Gaussian mixture models is frequently needed. We present a comparison of the Kullback-Leibler distance, the earth movers distance and the normalized L2 distance for this application. Although...

  9. Interspinous Process Decompression: Expanding Treatment Options for Lumbar Spinal Stenosis

    Directory of Open Access Journals (Sweden)

    Pierce D. Nunley

    2016-01-01

    Full Text Available Interspinous process decompression is a minimally invasive implantation procedure employing a stand-alone interspinous spacer that functions as an extension blocker to prevent compression of neural elements without direct surgical removal of tissue adjacent to the nerves. The Superion® spacer is the only FDA approved stand-alone device available in the US. It is also the only spacer approved by the CMS to be implanted in an ambulatory surgery center. We computed the within-group effect sizes from the Superion IDE trial and compared them to results extrapolated from two randomized trials of decompressive laminectomy. For the ODI, effect sizes were all very large (>1.0 for Superion and laminectomy at 2, 3, and 4 years. For ZCQ, the 2-year Superion symptom severity (1.26 and physical function (1.29 domains were very large; laminectomy effect sizes were very large (1.07 for symptom severity and large for physical function (0.80. Current projections indicate a marked increase in the number of patients with spinal stenosis. Consequently, there remains a keen interest in minimally invasive treatment options that delay or obviate the need for invasive surgical procedures, such as decompressive laminectomy or fusion. Stand-alone interspinous spacers may fill a currently unmet treatment gap in the continuum of care and help to reduce the burden of this chronic degenerative condition on the health care system.

  10. Surgical treatment of lumbar spinal stenosis with microdecompression and interspinous distraction device insertion. A case series

    Directory of Open Access Journals (Sweden)

    Ploumis Avraam

    2012-10-01

    Full Text Available Abstract Background Interspinous distraction devices (IPDD are indicated as stand-alone devices for the treatment of spinal stenosis. The purpose of this study is to evaluate the results of patients undergoing surgery for spinal stenosis with a combination of unilateral microdecompression and interspinous distraction device insertion. Methods This is a prospective clinical and radiological study of minimum 2 years follow-up. Twenty-two patients (average age 64.5 years with low-back pain and unilateral sciatica underwent decompressive surgery for lumbar spinal stenosis. Visual Analogue Scale, Oswestry Disability Index and walking capacity plus radiologic measurements of posterior disc height of the involved level and lumbar lordosis Cobb angle were documented both preoperatively and postoperatively. One-sided posterior subarticular and foraminal decompression was conducted followed by dynamic stabilization of the diseased level with an IPDD (X-STOP. Results The average follow-up time was 27.4 months. Visual Analogue Scale and Oswestry Disability Index improved statistically significantly (p Conclusions The described surgical technique using unilateral microdecompression and IPDD insertion is a clinically effective and radiologically viable treatment method for symptoms of spinal stenosis resistant to non-operative treatment.

  11. Measuring Astronomical Distances with Linear Programming

    Science.gov (United States)

    Narain, Akshar

    2015-01-01

    A few years ago it was suggested that the distance to celestial bodies could be computed by tracking their position over about 24 hours and then solving a regression problem. One only needed to use inexpensive telescopes, cameras, and astrometry tools, and the experiment could be done from one's backyard. However, it is not obvious to an amateur…

  12. A Survey of Binary Similarity and Distance Measures

    Directory of Open Access Journals (Sweden)

    Seung-Seok Choi

    2010-02-01

    Full Text Available The binary feature vector is one of the most common representations of patterns and measuring similarity and distance measures play a critical role in many problems such as clustering, classification, etc. Ever since Jaccard proposed a similarity measure to classify ecological species in 1901, numerous binary similarity and distance measures have been proposed in various fields. Applying appropriate measures results in more accurate data analysis. Notwithstanding, few comprehensive surveys on binary measures have been conducted. Hence we collected 76 binary similarity and distance measures used over the last century and reveal their correlations through the hierarchical clustering technique.

  13. Single-Image Distance Measurement by a Smart Mobile Device.

    Science.gov (United States)

    Chen, Shangwen; Fang, Xianyong; Shen, Jianbing; Wang, Linbo; Shao, Ling

    2017-12-01

    Existing distance measurement methods either require multiple images and special photographing poses or only measure the height with a special view configuration. We propose a novel image-based method that can measure various types of distance from single image captured by a smart mobile device. The embedded accelerometer is used to determine the view orientation of the device. Consequently, pixels can be back-projected to the ground, thanks to the efficient calibration method using two known distances. Then the distance in pixel is transformed to a real distance in centimeter with a linear model parameterized by the magnification ratio. Various types of distance specified in the image can be computed accordingly. Experimental results demonstrate the effectiveness of the proposed method.

  14. Femtosecond frequency comb based distance measurement in air

    NARCIS (Netherlands)

    Balling, P.; Kren, P.; Masika, P.; van den Berg, S.A.

    2009-01-01

    Interferometric measurement of distance using a femtosecond frequency comb is demonstrated and compared with a counting interferometer displacement measurement. A numerical model of pulse propagation in air is developed and the results are compared with experimental data for short distances. The

  15. Femtosecond frequency comb based distance measurement in air.

    Science.gov (United States)

    Balling, Petr; Kren, Petr; Masika, Pavel; van den Berg, S A

    2009-05-25

    Interferometric measurement of distance using a femtosecond frequency comb is demonstrated and compared with a counting interferometer displacement measurement. A numerical model of pulse propagation in air is developed and the results are compared with experimental data for short distances. The relative agreement for distance measurement in known laboratory conditions is better than 10(-7). According to the model, similar precision seems feasible even for long-distance measurement in air if conditions are sufficiently known. It is demonstrated that the relative width of the interferogram envelope even decreases with the measured length, and a fringe contrast higher than 90% could be obtained for kilometer distances in air, if optimal spectral width for that length and wavelength is used. The possibility of comb radiation delivery to the interferometer by an optical fiber is shown by model and experiment, which is important from a practical point of view.

  16. Comparative evaluation of ultrasound scanner accuracy in distance measurement

    Science.gov (United States)

    Branca, F. P.; Sciuto, S. A.; Scorza, A.

    2012-10-01

    The aim of the present study is to develop and compare two different automatic methods for accuracy evaluation in ultrasound phantom measurements on B-mode images: both of them give as a result the relative error e between measured distances, performed by 14 brand new ultrasound medical scanners, and nominal distances, among nylon wires embedded in a reference test object. The first method is based on a least squares estimation, while the second one applies the mean value of the same distance evaluated at different locations in ultrasound image (same distance method). Results for both of them are proposed and explained.

  17. Calibration Base Lines for Electronic Distance Measuring Instruments (EDMI)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A calibration base line (CBL) is a precisely measured, straight-line course of approximately 1,400 m used to calibrate Electronic Distance Measuring Instruments...

  18. Minimally invasive treatment of lumbar spinal stenosis with a novel interspinous spacer

    Directory of Open Access Journals (Sweden)

    Shabat S

    2011-09-01

    Full Text Available Shay Shabat1, Larry E Miller2,3, Jon E Block3, Reuven Gepstein11Spinal Care Unit, Sapir Medical Center, Kfar Saba, Israel; 2Miller Scientific Consulting, Inc, Biltmore Lake, NC, USA; 3Jon E Block, PhD, Inc, San Francisco, CA, USAPurpose: To assess the safety and effectiveness of a novel, minimally invasive interspinous spacer in patients with moderate lumbar spinal stenosis (LSS.Methods: A total of 53 patients (mean age, 70 ± 11 years; 45% female with intermittent neurogenic claudication secondary to moderate LSS, confirmed on imaging studies, were treated with the Superion® Interspinous Spacer (VertiFlex, Inc, San Clemente, CA and returned for follow-up visits at 6 weeks, 1 year, and 2 years. Study endpoints included axial and extremity pain severity with an 11-point numeric scale, Zurich Claudication Questionnaire (ZCQ, back function with the Oswestry Disability Index (ODI, health-related quality of life with the Physical Component Summary (PCS and Mental Component Summary (MCS scores from the SF-12, and adverse events.Results: Axial and extremity pain each decreased 54% (both P < 0.001 over the 2-year follow-up period. ZCQ symptom severity scores improved 43% (P < 0.001 and ZCQ physical function improved 44% (P < 0.001 from pre-treatment to 2 years post-treatment. A statistically significant 50% improvement (P < 0.001 also was noted in back function. PCS and MCS each improved 40% (both P < 0.001 from pre-treatment to 2 years. Clinical success rates at 2 years were 83%–89% for ZCQ subscores, 75% for ODI, 78% for PCS, and 80% for MCS. No device infection, implant breakage, migration, or pull-out was observed, although two (3.8% patients underwent explant with subsequent laminectomy.Conclusion: Moderate LSS can be effectively treated with a minimally invasive interspinous spacer. This device is appropriate for select patients who have failed nonoperative treatment measures for LSS and meet strict anatomical criteria.Keywords: Superion, axial

  19. Change of Measure between Light Travel Time and Euclidean Distances

    Directory of Open Access Journals (Sweden)

    Heymann Y.

    2013-04-01

    Full Text Available The problem of cosmological distances is approached using a method based on the propagation of light in an expanding Universe. From the chan ge of measure between Light Travel Time and Euclidean Distances, a formula is deri ved to compute distances as a function of redshift. This formula is identical to Matti g’s formula (with q 0 = 1 / 2 which is based on Friedmann’s equations of general relativi ty.

  20. Distance measures for image segmentation evaluation

    OpenAIRE

    Monteiro, Fernando C.; Campilho, Aurélio

    2012-01-01

    In this paper we present a study of evaluation measures that enable the quantification of the quality of an image segmentation result. Despite significant advances in image segmentation techniques, evaluation of these techniques thus far has been largely subjective. Typically, the effectiveness of a new algorithm is demonstrated only by the presentation of a few segmented images and is otherwise left to subjective evaluation by the reader. Such an evaluation criterion can be useful for differ...

  1. High-accuracy long distance measurements\

    Czech Academy of Sciences Publication Activity Database

    Lešundák, Adam; Voigt, D.; Číp, Ondřej; van der Berg, M.

    2017-01-01

    Roč. 25, č. 26 (2017), s. 32570-32580 ISSN 1094-4087 R&D Projects: GA ČR GB14-36681G; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : measurements * filtered frequency comb Subject RIV: BH - Optics , Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics ) Impact factor: 3.307, year: 2016

  2. Miniaturized diffraction based interferometric distance measurement sensor

    Science.gov (United States)

    Kim, Byungki

    In this thesis, new metrology hardware is designed, fabricated, and tested to provide improvements over current MEMS metrology. The metrology system is a micromachined scanning interferometer (muSI) having a sub-nm resolution in a compact design. The proposed microinterferometer forms a phase sensitive diffraction grating with interferomeric sensitivity, while adding the capability of better lateral resolution by focusing the laser to a smaller spot size. A detailed diffraction model of the microinterferometer was developed to simulate the device performance and to suggest the location of photo detectors for integrated optoelectronics. A particular device is fabricated on a fused silica substrate using aluminum to form the deformable diffraction grating fingers and AZ P4620 photo resist (PR) for the microlens. The details of the fabrication processes are presented. The structure also enables optoelectronics to be integrated so that the interferometer with photo detectors can fit in an area that is 1 mm x 1 mm. The scanning results using a fixed grating muSI demonstrated that it could measure vibration profile as well as static vertical (less than a half wave length) and lateral dimension of MEMS. The muSI, which is integrated with photo diodes, demonstrated its operation by scanning a cMUT. The PID control has been tested and resulted in improvement in scanned images. The integrated muSI demonstrated that the deformable grating could be used to tune the measurement keep the interferometer in quadrature for highest sensitivity.

  3. Is linear distance measured by panoramic radiography reliable?

    International Nuclear Information System (INIS)

    Nishikawa, Keiichi; Wakoh, Mamoru; Sano, Tsukasa; Suehiro, Atsushi; Sekine, Hideshi; Kousuge, Yuuji

    2010-01-01

    The objective of this study was to re-examine the reliability of distance measurements on clinical panoramic radiographs by comparing them with computed tomography (CT) images, from which the most accurate distance measurement is possible. Twenty pairs of images from patients examined both with panoramic radiography and CT for dental implant treatment planning in the premolar and molar regions of the mandible were used. The vertical linear distance between the alveolar crest and the closest mandibular canal was measured by three experienced oral radiologists on both images. The distances measured on panoramic radiographs were corrected for the magnification factor at the focal plane. Double-oblique cross-sectional images were used for CT. Pearson's correlation coefficient was calculated between distances obtained from both images. The paired t test was performed for statistical comparison. Error levels with the panoramic radiograph versus the CT image were also calculated. Pearson's correlation coefficient showed a significant strong linear correlation (R=0.90; p<0.01). However, the corrected value of distance measured on panoramic radiographs tended to be too small, and a significant difference was observed (p<0.05). The error level was approximately 10% (9.6±7.3%). Distance measurement on clinical panoramic radiographs is less reliable than CT images and cannot be recommended. (author)

  4. Measuring the distance between multiple sequence alignments.

    Science.gov (United States)

    Blackburne, Benjamin P; Whelan, Simon

    2012-02-15

    Multiple sequence alignment (MSA) is a core method in bioinformatics. The accuracy of such alignments may influence the success of downstream analyses such as phylogenetic inference, protein structure prediction, and functional prediction. The importance of MSA has lead to the proliferation of MSA methods, with different objective functions and heuristics to search for the optimal MSA. Different methods of inferring MSAs produce different results in all but the most trivial cases. By measuring the differences between inferred alignments, we may be able to develop an understanding of how these differences (i) relate to the objective functions and heuristics used in MSA methods, and (ii) affect downstream analyses. We introduce four metrics to compare MSAs, which include the position in a sequence where a gap occurs or the location on a phylogenetic tree where an insertion or deletion (indel) event occurs. We use both real and synthetic data to explore the information given by these metrics and demonstrate how the different metrics in combination can yield more information about MSA methods and the differences between them. MetAl is a free software implementation of these metrics in Haskell. Source and binaries for Windows, Linux and Mac OS X are available from http://kumiho.smith.man.ac.uk/whelan/software/metal/.

  5. Percutaneous Decompression of Lumbar Spinal Stenosis with a New Interspinous Device

    International Nuclear Information System (INIS)

    Masala, Salvatore; Fiori, Roberto; Bartolucci, Dario Alberto; Volpi, Tommaso; Calabria, Eros; Novegno, Federica; Simonetti, Giovanni

    2012-01-01

    Objective: This study was designed to evaluate the feasibility of the implantation of a new interspinous device (Falena) in patients with lumbar spinal stenosis. The clinical outcomes and imaging results were assessed by orthostatic MR during an up to 6-month follow-up period. Methods: Between October 2008 and February 2010, the Falena was implanted at a single level in 26 patients (17 men; mean age, 69 (range, 54–82) years) who were affected by degenerative lumbar spinal stenosis. All of the patients were clinically evaluated before the procedure and at 1 and 3 months. Furthermore, 20 patients have completed a 6-month follow-up. Pain was assessed before and after the intervention using the Visual Analogue Scale score and the Oswestry Disability Index questionnaire. Orthostatic MR imaging was performed before the implantation and at 3 months to assess the correlation with the clinical outcome. Results: The mean ODI score decreased from 48.9 before the device implantation to 31.2 at 1 month (p < 0.0001). The mean VAS score decreased from 7.6 before to 3.9 (p < 0.0001) at 1 month and 3.6 at 3 months after the procedure (p = 0.0115). These values were stable at 6 months evaluation. No postimplantation major complications were recorded. MRI evaluation documented in most cases an increased size of the spinal canal area. Similarly a bilateral foraminal area improvement was found. The variation of the intervertebral space height measured on the posterior wall was not significant. Conclusions: In our preliminary experience with the Falena in a small cohort of patients, we obtained clinical and imaging results aligned to those reported with similar interspinous devices.

  6. High Precision Infrared Temperature Measurement System Based on Distance Compensation

    Directory of Open Access Journals (Sweden)

    Chen Jing

    2017-01-01

    Full Text Available To meet the need of real-time remote monitoring of human body surface temperature for optical rehabilitation therapy, a non-contact high-precision real-time temperature measurement method based on distance compensation was proposed, and the system design was carried out. The microcontroller controls the infrared temperature measurement module and the laser range module to collect temperature and distance data. The compensation formula of temperature with distance wass fitted according to the least square method. Testing had been performed on different individuals to verify the accuracy of the system. The results indicate that the designed non-contact infrared temperature measurement system has a residual error of less than 0.2°C and the response time isless than 0.1s in the range of 0 to 60cm. This provides a reference for developing long-distance temperature measurement equipment in optical rehabilitation therapy.

  7. An adaptive distance measure for use with nonparametric models

    International Nuclear Information System (INIS)

    Garvey, D. R.; Hines, J. W.

    2006-01-01

    Distance measures perform a critical task in nonparametric, locally weighted regression. Locally weighted regression (LWR) models are a form of 'lazy learning' which construct a local model 'on the fly' by comparing a query vector to historical, exemplar vectors according to a three step process. First, the distance of the query vector to each of the exemplar vectors is calculated. Next, these distances are passed to a kernel function, which converts the distances to similarities or weights. Finally, the model output or response is calculated by performing locally weighted polynomial regression. To date, traditional distance measures, such as the Euclidean, weighted Euclidean, and L1-norm have been used as the first step in the prediction process. Since these measures do not take into consideration sensor failures and drift, they are inherently ill-suited for application to 'real world' systems. This paper describes one such LWR model, namely auto associative kernel regression (AAKR), and describes a new, Adaptive Euclidean distance measure that can be used to dynamically compensate for faulty sensor inputs. In this new distance measure, the query observations that lie outside of the training range (i.e. outside the minimum and maximum input exemplars) are dropped from the distance calculation. This allows for the distance calculation to be robust to sensor drifts and failures, in addition to providing a method for managing inputs that exceed the training range. In this paper, AAKR models using the standard and Adaptive Euclidean distance are developed and compared for the pressure system of an operating nuclear power plant. It is shown that using the standard Euclidean distance for data with failed inputs, significant errors in the AAKR predictions can result. By using the Adaptive Euclidean distance it is shown that high fidelity predictions are possible, in spite of the input failure. In fact, it is shown that with the Adaptive Euclidean distance prediction

  8. Index of Refraction Measurements Using a Laser Distance Meter

    Science.gov (United States)

    Ochoa, Romulo; Fiorillo, Richard; Ochoa, Cris

    2014-01-01

    We present a simple method to determine the refractive indices of transparent media using a laser distance meter. Indices of refraction have been obtained by measuring the speed of light in materials. Some speed of light techniques use time-of-flight measurements in which pulses are emitted by lasers and the time interval is measured for the pulse…

  9. Interspinous process device versus standard conventional surgical decompression for lumbar spinal stenosis: Randomized controlled trial

    NARCIS (Netherlands)

    W.A. Moojen (Wouter); M.P. Arts (Mark); W.C.H. Jacobs (Wilco); E.W. van Zwet (Erik); M.E. van den Akker-van Marle (Elske); B.W. Koes (Bart); C.L.A.M. Vleggeert-Lankamp (Carmen); W.C. Peul (Wilco)

    2013-01-01

    markdownabstractAbstract Objective To assess whether interspinous process device implantation is more effective in the short term than conventional surgical decompression for patients with intermittent neurogenic claudication due to lumbar spinal stenosis. Design Randomized controlled

  10. Isolation and Characterization of Human Mesenchymal Stem Cells From Facet Joints and Interspinous Ligaments.

    Science.gov (United States)

    Kristjánsson, Baldur; Limthongkul, Worawat; Yingsakmongkol, Wicharn; Thantiworasit, Pattarawat; Jirathanathornnukul, Napaphat; Honsawek, Sittisak

    2016-01-01

    A descriptive in vitro study on isolation and differentiation of human mesenchymal stem cells (MSCs) derived from the facet joints and interspinous ligaments. To isolate cells from the facet joints and interspinous ligaments and investigate their surface marker profile and differentiation potentials. Lumbar spinal canal stenosis and ossification of the posterior longitudinal ligament are progressive conditions characterized by the hypertrophy and ossification of ligaments and joints within the spinal canal. MSCs are believed to play a role in the advancement of these diseases and the existence of MSCs has been demonstrated within the ligamentum flavum and posterior longitudinal ligament. The aim of this study was to investigate whether these cells could also be found within facet joints and interspinous ligaments. Samples were harvested from 10 patients undergoing spinal surgery. The MSCs from facet joints and interspinous ligaments were isolated using direct tissue explant technique. Cell surface antigen profilings were performed via flow cytometry. Their lineage differentiation potentials were analyzed. The facet joints and interspinous ligaments-derived MSCs have the tri-lineage potential to be differentiated into osteogenic, adipogenic, and chondrogenic cells under appropriate inductions. Flow cytometry analysis revealed both cell lines expressed MSCs markers. Both facet joints and interspinous ligaments-derived MSCs expressed marker genes for osteoblasts, adipocytes, and chondrocytes. The facet joints and interspinous ligaments may provide alternative sources of MSCs for tissue engineering applications. The facet joints and interspinous ligaments-derived MSCs are part of the microenvironment of the human ligaments of the spinal column and might play a crucial role in the development and progression of degenerative spine conditions.

  11. Study of probe-sample distance for biomedical spectra measurement

    Directory of Open Access Journals (Sweden)

    Li Lei

    2011-11-01

    Full Text Available Abstract Background Fiber-based optical spectroscopy has been widely used for biomedical applications. However, the effect of probe-sample distance on the collection efficiency has not been well investigated. Method In this paper, we presented a theoretical model to maximize the illumination and collection efficiency in designing fiber optic probes for biomedical spectra measurement. This model was in general applicable to probes with single or multiple fibers at an arbitrary incident angle. In order to demonstrate the theory, a fluorescence spectrometer was used to measure the fluorescence of human finger skin at various probe-sample distances. The fluorescence spectrum and the total fluorescence intensity were recorded. Results The theoretical results show that for single fiber probes, contact measurement always provides the best results. While for multi-fiber probes, there is an optimal probe distance. When a 400- μm excitation fiber is used to deliver the light to the skin and another six 400- μm fibers surrounding the excitation fiber are used to collect the fluorescence signal, the experimental results show that human finger skin has very strong fluorescence between 475 nm and 700 nm under 450 nm excitation. The fluorescence intensity is heavily dependent on the probe-sample distance and there is an optimal probe distance. Conclusions We investigated a number of probe-sample configurations and found that contact measurement could be the primary choice for single-fiber probes, but was very inefficient for multi-fiber probes. There was an optimal probe-sample distance for multi-fiber probes. By carefully choosing the probe-sample distance, the collection efficiency could be enhanced by 5-10 times. Our experiments demonstrated that the experimental results of the probe-sample distance dependence of collection efficiency in multi-fiber probes were in general agreement with our theory.

  12. The Felix-trial. Double-blind randomization of interspinous implant or bony decompression for treatment of spinal stenosis related intermittent neurogenic claudication

    Directory of Open Access Journals (Sweden)

    Brand Ronald

    2010-05-01

    Full Text Available Abstract Background Decompressive laminotomy is the standard surgical procedure in the treatment of patients with canal stenosis related intermittent neurogenic claudication. New techniques, such as interspinous process implants, claim a shorter hospital stay, less post-operative pain and equal long-term functional outcome. A comparative (cost- effectiveness study has not been performed yet. This protocol describes the design of a randomized controlled trial (RCT on (cost- effectiveness of the use of interspinous process implants versus conventional decompression surgery in patients with lumbar spinal stenosis. Methods/Design Patients (age 40-85 presenting with intermittent neurogenic claudication due to lumbar spinal stenosis lasting more than 3 months refractory to conservative treatment, are included. Randomization into interspinous implant surgery versus bony decompression surgery will take place in the operating room after induction of anesthesia. The primary outcome measure is the functional assessment of the patient measured by the Zurich Claudication Questionnaire (ZCQ, at 8 weeks and 1 year after surgery. Other outcome parameters include perceived recovery, leg and back pain, incidence of re-operations, complications, quality of life, medical consumption, absenteeism and costs. The study is a randomized multi-institutional trial, in which two surgical techniques are compared in a parallel group design. Patients and research nurses are kept blinded of the allocated treatment during the follow-up period of 1 year. Discussion Currently decompressive laminotomy is the golden standard in the surgical treatment of lumbar spinal stenosis. Whether surgery with interspinous implants is a reasonable alternative can be determined by this trial. Trial register Dutch Trial register number: NTR1307

  13. The Edit Distance as a Measure of Perceived Rhythmic Similarity

    Directory of Open Access Journals (Sweden)

    Olaf Post

    2012-07-01

    Full Text Available The ‘edit distance’ (or ‘Levenshtein distance’ measure of distance between two data sets is defined as the minimum number of editing operations – insertions, deletions, and substitutions – that are required to transform one data set to the other (Orpen and Huron, 1992. This measure of distance has been applied frequently and successfully in music information retrieval, but rarely in predicting human perception of distance. In this study, we investigate the effectiveness of the edit distance as a predictor of perceived rhythmic dissimilarity under simple rhythmic alterations. Approaching rhythms as a set of pulses that are either onsets or silences, we study two types of alterations. The first experiment is designed to test the model’s accuracy for rhythms that are relatively similar; whether rhythmic variations with the same edit distance to a source rhythm are also perceived as relatively similar by human subjects. In addition, we observe whether the salience of an edit operation is affected by its metric placement in the rhythm. Instead of using a rhythm that regularly subdivides a 4/4 meter, our source rhythm is a syncopated 16-pulse rhythm, the son. Results show a high correlation between the predictions by the edit distance model and human similarity judgments (r = 0.87; a higher correlation than for the well-known generative theory of tonal music (r = 0.64. In the second experiment, we seek to assess the accuracy of the edit distance model in predicting relatively dissimilar rhythms. The stimuli used are random permutations of the son’s inter-onset intervals: 3-3-4-2-4. The results again indicate that the edit distance correlates well with the perceived rhythmic dissimilarity judgments of the subjects (r = 0.76. To gain insight in the relationships between the individual rhythms, the results are also presented by means of graphic phylogenetic trees.

  14. Radio Astronomers Set New Standard for Accurate Cosmic Distance Measurement

    Science.gov (United States)

    1999-06-01

    A team of radio astronomers has used the National Science Foundation's Very Long Baseline Array (VLBA) to make the most accurate measurement ever made of the distance to a faraway galaxy. Their direct measurement calls into question the precision of distance determinations made by other techniques, including those announced last week by a team using the Hubble Space Telescope. The radio astronomers measured a distance of 23.5 million light-years to a galaxy called NGC 4258 in Ursa Major. "Ours is a direct measurement, using geometry, and is independent of all other methods of determining cosmic distances," said Jim Herrnstein, of the National Radio Astronomy Observatory (NRAO) in Socorro, NM. The team says their measurement is accurate to within less than a million light-years, or four percent. The galaxy is also known as Messier 106 and is visible with amateur telescopes. Herrnstein, along with James Moran and Lincoln Greenhill of the Harvard- Smithsonian Center for Astrophysics; Phillip Diamond, of the Merlin radio telescope facility at Jodrell Bank and the University of Manchester in England; Makato Inoue and Naomasa Nakai of Japan's Nobeyama Radio Observatory; Mikato Miyoshi of Japan's National Astronomical Observatory; Christian Henkel of Germany's Max Planck Institute for Radio Astronomy; and Adam Riess of the University of California at Berkeley, announced their findings at the American Astronomical Society's meeting in Chicago. "This is an incredible achievement to measure the distance to another galaxy with this precision," said Miller Goss, NRAO's Director of VLA/VLBA Operations. "This is the first time such a great distance has been measured this accurately. It took painstaking work on the part of the observing team, and it took a radio telescope the size of the Earth -- the VLBA -- to make it possible," Goss said. "Astronomers have sought to determine the Hubble Constant, the rate of expansion of the universe, for decades. This will in turn lead to an

  15. Instrumentação interespinhosa na doença degenerativa da coluna lombar: medição da altura do disco no segmento instrumentado Instrumentación interespinosa en la enfermedad degenerativa de la columna lumbar: medición de la altura del disco en el segmento instrumentado Interspinous instrumentation in patients with degenerative lumbar spine disease: disc height measurement on instrumented segment

    Directory of Open Access Journals (Sweden)

    José Alberto de Castro Guimarães Consciência

    2009-09-01

    criteria: age >40 and 6; Oswestry Inability Index >30; Zung Depression Rating Scale <39; Modified Somatic Perception Questionnaire <15; degenerative bone disease grade 2 and 3 according to Benzel classification and degenerative disk disease grade 3 and 4 according to Pfirmann classification. Using a special formula and a computer image program (Adobe Photoshop 9.0 CS2, side radiograms of the lumbar spine in orthostatic position and with 70% amplification were obtained pre-surgery and two years after surgery. RESULTS: after applying the mentioned formula, the results showed an increased global disk height average 1.53 mm, with a standard deviation of 1.09 mm and p=0.0002. However, there was a large increase (0.45 mm in posterior disk height (p=0.0002 when compared with anterior measurement (p=0.001 pointing out a slight kyphosing effect related to the instrumentation. CONCLUSIONS: in Benzel grade 2 and 3 and Pfirmann grade 3 and 4 degenerative lumbar disease, the use of an interspinous system seemed to be able to increase disk height and to improve neural canal dimensions.

  16. Recoil distance lifetime measurements in 122,124Xe

    Science.gov (United States)

    Govil, I. M.; Kumar, A.; Iyer, H.; Li, H.; Garg, U.; Ghugre, S. S.; Johnson, T.; Kaczarowski, R.; Kharraja, B.; Naguleswaran, S.; Walpe, J. C.

    1998-02-01

    Lifetimes of the lower-excited states in 122,124Xe are measured using the recoil-distance Doppler-shift technique. The reactions 110Pd(16O,4n)122Xe and 110Pd(18O,4n)124Xe at a beam energy of 66 MeV were used for this experiment. The lifetimes of the 2+, 4+, 6+, and 8+ states of the ground state band were extracted using the computer code LIFETIME including the corrections due to the side feeding and the nuclear deorientation effects. The lifetime of the 2+ state in 122Xe agrees with the recoil distance method (RDM) measurements but for the 124Xe it does not agree with the RDM measurements but agrees with the Coulomb-excitation experiment. The measured B(E2) values for both the nuclei are compared with the standard algebraic and the multishell models.

  17. Measuring short distance dispersal of Alliaria petiolata and determining potential long distance dispersal mechanisms

    Directory of Open Access Journals (Sweden)

    Christopher A. Loebach

    2018-03-01

    Full Text Available Introduction Alliaria petiolata, an herbaceous plant, has invaded woodlands in North America. Its ecology has been thoroughly studied, but an overlooked aspect of its biology is seed dispersal distances and mechanisms. We measured seed dispersal distances in the field and tested if epizoochory is a potential mechanism for long-distance seed dispersal. Methods Dispersal distances were measured by placing seed traps in a sector design around three seed point sources, which consisted of 15 second-year plants transplanted within a 0.25 m radius circle. Traps were placed at intervals ranging from 0.25–3.25 m from the point source. Traps remained in the field until a majority of seeds were dispersed. Eight probability density functions were fitted to seed trap counts via maximum likelihood. Epizoochory was tested as a potential seed dispersal mechanism for A. petiolata through a combination of field and laboratory experiments. To test if small mammals transport A. petiolata seeds in their fur, experimental blocks were placed around dense A. petiolata patches. Each block contained a mammal inclusion treatment (MIT and control. The MIT consisted of a wood-frame (31 × 61× 31 cm covered in wire mesh, except for the two 31 × 31 cm ends, placed over a germination tray filled with potting soil. A pan filled with bait was placed in the center of the tray. The control frame (11 × 31 × 61 cm was placed over a germination tray and completely covered in wire mesh to exclude animal activity. Treatments were in the field for peak seed dispersal. In March, trays were moved to a greenhouse and A. petiolata seedlings were counted and then compared between treatments. To determine if A. petiolata seeds attach to raccoon (Procyon lotor and white-tailed deer (Odocoileus virginianus fur, wet and dry seeds were dropped onto wet and dry fur. Furs were rotated 180 degrees and the seeds that remained attached were counted. To measure seed retention, seeds

  18. Measuring the Distance of Moving Objects from Big Trajectory Data

    Directory of Open Access Journals (Sweden)

    Khaing Phyo Wai

    2017-03-01

    Full Text Available Location-based services have become important in social networking, mobile applications, advertising, traffic monitoring, and many other domains. The growth of location sensing devices has led to the vast generation of dynamic spatial-temporal data in the form of moving object trajectories which can be characterized as big trajectory data. Big trajectory data enables the opportunities such as analyzing the groups of moving objects. To obtain such facilities, the issue of this work is to find a distance measurement method that respects the geographic distance and the semantic similarity for each trajectory. Measurement of similarity between moving objects is a difficult task because not only their position changes but also their semantic features vary. In this research, a method to measure trajectory similarity based on both geographical features and semantic features of motion is proposed. Finally, the proposed methods are practically evaluated by using real trajectory dataset.

  19. Ultrasound measurement of transcranial distance during head-down tilt

    Science.gov (United States)

    Torikoshi, S.; Wilson, M. H.; Ballard, R. E.; Watenpaugh, D. E.; Murthy, G.; Yost, W. T.; Cantrell, J. H.; Chang, D. S.; Hargens, A. R.

    1995-01-01

    Exposure to microgravity elevates blood pressure and flow in the head, which may increase intracranial volume (ICV) and intracranial pressure (ICP). Rhesus monkeys exposed to simulated microgravity in the form of 6 degree head-down tilt (HDT) experience elevated ICP. With humans, twenty-four hours of 6 degree HDT bed rest increases cerebral blood flow velocity relative to pre-HDT upright posture. Humans exposed to acute 6 degree HDT experiments increased ICP, measured with the tympanic membrane displacement (TMD) technique. Other studies suggest that increased ICP in humans and cats causes measurable cranial bone movement across the sagittal suture. Due to the slightly compliant nature of the cranium, elevation of the ICP will increase ICV and transcranial distance. Currently, several non-invasive approaches to monitor ICP are being investigated. Such techniques include TMD and modal analysis of the skull. TMD may not be reliable over a large range of ICP and neither method is capable of measuring the small changes in pressure. Ultrasound, however, may reliably measure small distance changes that accompany ICP fluctuations. The purpose of our study was to develop and evaluate an ultrasound technique to measure transcranial distance changes during HDT.

  20. Bullet Ultrasonic Obstruction Detection & Distance Measurement Using AVR Microcontroller

    Directory of Open Access Journals (Sweden)

    Satish Pandey

    2008-08-01

    Full Text Available This paper describes the practical implementation of a short range ultrasonic obstruction detection and distance measurement device. By employing an ultrasonic transducer pair for producing ultrasonic sounds and sensing the reflected sound waves, the obstructions are detected. The hardware interface uses an Atmel ATmega8 AVR microcontroller to facilitate the generation of 40 kHz signal burst which is used in the transmitter circuit, and also to process the received signal for measuring the time of flight of reflected waves and exact distance of the obstruction. The program for this device is developed in WinAVR, and the code generated is dumped into microcontroller using AVR Studio. Educational aspects of this project include the mastery of a programming language and corresponding tools, the design of a functional and intuitive embedded application, and the development of appropriate hardware to build the device.

  1. RFDR with Adiabatic Inversion Pulses: Application to Internuclear Distance Measurements

    International Nuclear Information System (INIS)

    Leppert, Joerg; Ohlenschlaeger, Oliver; Goerlach, Matthias; Ramachandran, Ramadurai

    2004-01-01

    In the context of the structural characterisation of biomolecular systems via MAS solid state NMR, the potential utility of homonuclear dipolar recoupling with adiabatic inversion pulses has been assessed via numerical simulations and experimental measurements. The results obtained suggest that it is possible to obtain reliable estimates of internuclear distances via an analysis of the initial cross-peak intensity buildup curves generated from two-dimensional adiabatic inversion pulse driven longitudinal magnetisation exchange experiments

  2. EPR-based distance measurements at ambient temperature

    Science.gov (United States)

    Krumkacheva, Olesya; Bagryanskaya, Elena

    2017-07-01

    Pulsed dipolar (PD) EPR spectroscopy is a powerful technique allowing for distance measurements between spin labels in the range of 2.5-10.0 nm. It was proposed more than 30 years ago, and nowadays is widely used in biophysics and materials science. Until recently, PD EPR experiments were limited to cryogenic temperatures (T biomolecules, the influence of a linker between the spin probe and biomolecule, and future opportunities.

  3. Experience of precision measuring distances by invar wires at accelerators

    International Nuclear Information System (INIS)

    Porubaj, N.I.

    1977-01-01

    With a view to determining the deformations and displacements of the ring foundation of the ITEP accelerator, the method of very accurate distance measurements by means of invar wires and strips is described. Measurement errors are analyzed. This method has allowed to measure distances up to 40 m with a mean-square error of less than 40 μm. The calibration accuracy of 3 and 25-m measuring wires has been determined to be +- 27 μm. Time instability of the wires is +- 16 μm. It is shown that strips are more stable in time than wires. Elongation of 6, 19, 25 and 38 m invar wires has been measured as function of the tension time. The error due to tension of a 38-m wire may be tangible. Data on thermal coefficient variation in time has been obtained for invar wires and strips. The multiannual measurements of the ring foundation deformations show that variations of the mean radius are caused by increases of concrete temperature. Temperature increase by only 1 deg caused mean radius increase of 0.3 mm

  4. Precision lifetime measurements using the recoil distance method

    International Nuclear Information System (INIS)

    Kruecken, R.

    2000-01-01

    The recoil distance method (RDM) for the measurements of lifetimes of excited nuclear levels in the range from about 1 ps to 1,000 ps is reviewed. The New Yale Plunger Device for RDM experiments is introduced and the Differential Decay Curve Method for their analysis is reviewed. Results from recent RDM experiments on SD bands in the mass-190 region, shears bands in the neutron deficient lead isotopes, and ground state bands in the mass-130 region are presented. Perspectives for the use of RDM measurements in the study of neutron-rich nuclei are discussed

  5. Precision Lifetime Measurements Using the Recoil Distance Method

    Science.gov (United States)

    Krücken, R.

    2000-01-01

    The recoil distance method (RDM) for the measurements of lifetimes of excited nuclear levels in the range from about 1 ps to 1000 ps is reviewed. The New Yale Plunger Device for RDM experiments is introduced and the Differential Decay Curve Method for their analysis is reviewed. Results from recent RDM experiments on SD bands in the mass-190 region, shears bands in the neutron deficient lead isotopes, and ground state bands in the mass-130 region are presented. Perspectives for the use of RDM measurements in the study of neutron-rich nuclei are discussed. PMID:27551587

  6. A Game Map Complexity Measure Based on Hamming Distance

    Science.gov (United States)

    Li, Yan; Su, Pan; Li, Wenliang

    With the booming of PC game market, Game AI has attracted more and more researches. The interesting and difficulty of a game are relative with the map used in game scenarios. Besides, the path-finding efficiency in a game is also impacted by the complexity of the used map. In this paper, a novel complexity measure based on Hamming distance, called the Hamming complexity, is introduced. This measure is able to estimate the complexity of binary tileworld. We experimentally demonstrated that Hamming complexity is highly relative with the efficiency of A* algorithm, and therefore it is a useful reference to the designer when developing a game map.

  7. Student Performance in Measuring Distance with Wavelengths in Various Settings

    Science.gov (United States)

    White, Gary

    2015-04-01

    When physics students are asked to measure the distance between two fixed locations using a pre-defined wavelength as a ruler, there is a surprising failure rate, at least partially due to the fact that the ``ruler'' to be used is not fixed in length (see ``Is a Simple Measurement Task a Roadblock to Student Understanding of Wave Phenomena?,'' by and references therein). I will show some data from introductory classes (algebra- and calculus-based) that replicate this result, and also show some interesting features when comparing a setting involving slinkies with a setting involving surface waves on water.

  8. Performance considerations of ultrasonic distance measurement with well defined properties

    International Nuclear Information System (INIS)

    Elmer, Hannes; Schweinzer, Herbert

    2005-01-01

    Conventional ultrasonic distance measurement systems based on narrow bandwidth ultrasonic bursts and amplitude detection are often used because of their low costs and easy implementation. However, the achievable results strongly depend on the actual environments where the system is implemented: in case of well defined objects that are always located near the measurement direction of the system, in general good results are obtained. If arbitrary objects are expected that are moreover located in arbitrary positions in front of the sensor, strongly object dependent areas where objects are detected with decreasing accuracy towards their borders must be taken into account. In previous works we developed an ultrasonic measurement system that provides accurate distance measurement values within a well defined detection area that is independent of the reflection properties of the objects. This measurement system is based on the One Bit Correlation method that is described in the following. To minimise its implementation efforts, it is necessary to examine the influence of the system parameters as e.g. the correlation length to the results that are expected in case of different signal to noise ratios of the received signal. In the following, these examinations are shown and the obtained results are discussed that allow getting a well conditioned system that makes best use of given system resources

  9. Lifetime measurements using the recoil distance method - achievements and perspectives

    International Nuclear Information System (INIS)

    Kruecken, R.

    2001-01-01

    The recoil distance method (RDM) for measuring pico-second nuclear level lifetimes and its use in nuclear structure studies is reviewed and perspectives for the future are presented. High precision measurements in the mass-130 region, studies of multi-phonon states in rare earth nuclei, the investigation of shape coexistence and the recently discovered phenomenon of 'magnetic rotation' are reviewed. Prospects for lifetime measurements in exotic regions of nuclei such as the measurement of lifetimes in neutron rich nuclei populated via spontaneous and heavy-ion induced fission are discussed. Other prospects include the use of the RDM technique in conjunction with recoil separators. The relevance of these techniques for experiments with radioactive ion beams will be discussed

  10. THE DISTANCE MEASUREMENT OF NGC 1313 WITH CEPHEIDS

    International Nuclear Information System (INIS)

    Qing, Gao; Wang, Wei; Liu, Ji-Feng; Yoachim, Peter

    2015-01-01

    We present the detection of Cepheids in the barred spiral galaxy NGC 1313, using the Wide Field and Planetary Camera 2 on the Hubble Space Telescope. Twenty B(F450W) and V(F555W) epochs of observations spanning over three weeks were obtained, on which the profile-fitting photometry of all stars in the monitored field was performed using the package HSTphot. A sample of 26 variable stars have been identified to be Cepheids, with periods between 3 and 14 days. Based on the derived period-luminosity relations in B- and V-bands, we obtain an extinction-corrected distance modulus of μ NGC 1313 = 28.32 ± 0.08 (random) ± 0.06 (systematic), employing the Large Magellanic Cloud as the distance zero point calibrator. The above moduli correspond to a distance of 4.61 ± 0.17 (random) ±0.13 (systematic) Mpc, consistent with previous measurements reported in the literature within uncertainties. In addition, the reddening to NGC 1313 is found to be small

  11. New Trends Of Measurement And Assessment In Distance Education

    Directory of Open Access Journals (Sweden)

    Zeki KAYA

    2014-01-01

    Full Text Available Distance education is a discipline that offers solutions to some important education problems. Distance education, contribute to the solution to the problems such as; inequality of opportunities, lifelong education, the implementation of a series of individual and social goals that can contribute to and benefit from educational technology and self-learning. In distance education, methods of measurement and assessment must be consistent with the objectives and contents of teaching. A major interest of formative assessment is determining the students’ learning level of each behavior in the interested unit. In summative assessment, performances of students on some units are measured broader than formative assessment. A computerized adaptive testing, CAT, is the test managed by computer in which each item is introduced and the decision to stop are dynamically imposed based on the students answers and his/her estimated knowledge level. In CAT applications, students do not take the same test. Despite item numbers and properties of items are different for the students; the precise of measures improves in positioning students on an ability or success continuum in CAT applications. In CAT applications, questions answered by a student depend on the student's ability or learning level. In item response theory, there are some models to estimate a student’s ability level, such as three-parameter logistic model. Cheating in exams or other academic assignments can be defined as use resources not allowed to use or having someone else to take exams or assignments. Some precautions must be taken about cheating such as a live proctoring, using web cams, and using a plagiarism detection program.

  12. Distance measurements from supernovae and dark energy constraints

    International Nuclear Information System (INIS)

    Wang Yun

    2009-01-01

    Constraints on dark energy from current observational data are sensitive to how distances are measured from Type Ia supernova (SN Ia) data. We find that flux averaging of SNe Ia can be used to test the presence of unknown systematic uncertainties, and yield more robust distance measurements from SNe Ia. We have applied this approach to the nearby+SDSS+ESSENCE+SNLS+HST set of 288 SNe Ia, and the 'Constitution' set of 397 SNe Ia. Combining the SN Ia data with cosmic microwave background anisotropy data from Wilkinson Microwave Anisotropy Probe 5 yr observations, the Sloan Digital Sky Survey baryon acoustic oscillation measurements, the data of 69 gamma-ray bursts (GRBs) , and the Hubble constant measurement from the Hubble Space Telescope project SHOES, we measure the dark energy density function X(z)≡ρ X (z)/ρ X (0) as a free function of redshift (assumed to be a constant at z>1 or z>1.5). Without the flux averaging of SNe Ia, the combined data using the Constitution set of SNe Ia seem to indicate a deviation from a cosmological constant at ∼95% confidence level at 0 98% confidence level for z≤0.75 using the combined data with 288 SNe Ia from nearby+SDSS+ESSENCE+SNLS+HST, independent of the assumptions about X(z≥1). We quantify dark energy constraints without assuming a flat Universe using the dark energy figure of merit for both X(z) and a dark energy equation-of-state linear in the cosmic scale factor.

  13. Epidural cystic masses associated with interspinous bursitis, synovial and discal cysts

    International Nuclear Information System (INIS)

    Santos, Frederico Guilherme de Paula Lopes; Souza, Ricardo Andre de; Brotto, Marcos Pama D'Almeida; Suguita, Fabio Massaaki; Amaral, Denise Tokechi; Amaral, Lazaro Luis Faria do

    2009-01-01

    The authors describe some cases of epidural cysts, namely synovial, discal, ligamentum flavum cysts, and cysts secondary to interspinous bursitis, all of these conditions determining radicular, dural sac compression or spinal canal stenosis. Magnetic resonance imaging findings and localization of these entities are described. (author)

  14. The correction of vibration in frequency scanning interferometry based absolute distance measurement system for dynamic measurements

    Science.gov (United States)

    Lu, Cheng; Liu, Guodong; Liu, Bingguo; Chen, Fengdong; Zhuang, Zhitao; Xu, Xinke; Gan, Yu

    2015-10-01

    Absolute distance measurement systems are of significant interest in the field of metrology, which could improve the manufacturing efficiency and accuracy of large assemblies in fields such as aircraft construction, automotive engineering, and the production of modern windmill blades. Frequency scanning interferometry demonstrates noticeable advantages as an absolute distance measurement system which has a high precision and doesn't depend on a cooperative target. In this paper , the influence of inevitable vibration in the frequency scanning interferometry based absolute distance measurement system is analyzed. The distance spectrum is broadened as the existence of Doppler effect caused by vibration, which will bring in a measurement error more than 103 times bigger than the changes of optical path difference. In order to decrease the influence of vibration, the changes of the optical path difference are monitored by a frequency stabilized laser, which runs parallel to the frequency scanning interferometry. The experiment has verified the effectiveness of this method.

  15. A Test of the Validity of Projective and Quasi-Projective Measures of Interpersonal Distance.

    Science.gov (United States)

    Jones, Stanley E.; Aiello, John R.

    1979-01-01

    Discusses research supporting the conclusion that projective and quasi-projective measures of interpersonal distance do not measure the same phenomena as interactional measures. It is possible that they are more indicative of psychological rather than physical distance. (JMF)

  16. EPR-based distance measurements at ambient temperature.

    Science.gov (United States)

    Krumkacheva, Olesya; Bagryanskaya, Elena

    2017-07-01

    Pulsed dipolar (PD) EPR spectroscopy is a powerful technique allowing for distance measurements between spin labels in the range of 2.5-10.0nm. It was proposed more than 30years ago, and nowadays is widely used in biophysics and materials science. Until recently, PD EPR experiments were limited to cryogenic temperatures (TEPR as well as other approaches based on EPR (e.g., relaxation enhancement; RE). In this paper, we review the features of PD EPR and RE at ambient temperatures, in particular, requirements on electron spin phase memory time, ways of immobilization of biomolecules, the influence of a linker between the spin probe and biomolecule, and future opportunities. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Long distance measurement with a femtosecond laser based frequency comb

    Science.gov (United States)

    Bhattacharya, N.; Cui, M.; Zeitouny, M. G.; Urbach, H. P.; van den Berg, S. A.

    2017-11-01

    Recent advances in the field of ultra-short pulse lasers have led to the development of reliable sources of carrier envelope phase stabilized femtosecond pulses. The pulse train generated by such a source has a frequency spectrum that consists of discrete, regularly spaced lines known as a frequency comb. In this case both the frequency repetition and the carrier-envelope-offset frequency are referenced to a frequency standard, like an atomic clock. As a result the accuracy of the frequency standard is transferred to the optical domain, with the frequency comb as transfer oscillator. These unique properties allow the frequency comb to be applied as a versatile tool, not only for time and frequency metrology, but also in fundamental physics, high-precision spectroscopy, and laser noise characterization. The pulse-to-pulse phase relationship of the light emitted by the frequency comb has opened up new directions for long range highly accurate distance measurement.

  18. Philtrum length and intercommissural distance measurements at mixed dentition period.

    Science.gov (United States)

    Mostafa, Mostafa; Hassib, Nehal; Sayed, Inas; Neamat, Amany; Ramzy, Magda; El-Badry, Tarek; ElGabry, Hisham; Salem, Haidy; Omar, Nada; Ismail, Amira; Ibrahim, Yousra; Shebaita, Amr; Allam, Ahmed; Mostafa, Magdy

    2018-05-01

    Anthropometric measurements of the lip and mouth are of great importance in clinical dysmorphology as well as reconstructive plastic surgery. In this study, the philtrum length (PhL) and intercommissural distance (ICmD) nomograms for Egyptian children in the mixed dentition period were established. A group of 1,338 Egyptian students in primary schools (735 boys and 603 girls) were included in the study. The students were at mixed dentition period and their ages ranged from 7 to 12 years. Anthropometric norms of PhL and ICmD were developed with significant sex difference in certain groups. A ratio between PhL and ICmD was developed. These data will help facilitate both objective and subjective evaluation of the lip and mouth for proper diagnosis of orofacial anomalies and variations as well as for ideal treatment plans. © 2018 Wiley Periodicals, Inc.

  19. Effectiveness of interspinous implant surgery in patients with intermittent neurogenic claudication: a systematic review and meta-analysis

    NARCIS (Netherlands)

    Moojen, W.A.; Arts, M.P.; Bartels, R.H.M.A.; Jacobs, W.C.; Peul, W.C.

    2011-01-01

    INTRODUCTION: Despite an increasing implantation rate of interspinous process distraction (IPD) devices in the treatment of intermittent neurogenic claudication (INC), definitive evidence on the clinical effectiveness of implants is lacking. The main objective of this review was to perform a

  20. Distance Measurement Methods for Improved Insider Threat Detection

    Directory of Open Access Journals (Sweden)

    Owen Lo

    2018-01-01

    Full Text Available Insider threats are a considerable problem within cyber security and it is often difficult to detect these threats using signature detection. Increasing machine learning can provide a solution, but these methods often fail to take into account changes of behaviour of users. This work builds on a published method of detecting insider threats and applies Hidden Markov method on a CERT data set (CERT r4.2 and analyses a number of distance vector methods (Damerau–Levenshtein Distance, Cosine Distance, and Jaccard Distance in order to detect changes of behaviour, which are shown to have success in determining different insider threats.

  1. Properties of an interspinous fixation device (ISD) in lumbar fusion constructs: a biomechanical study.

    Science.gov (United States)

    Techy, Fernando; Mageswaran, Prasath; Colbrunn, Robb W; Bonner, Tara F; McLain, Robert F

    2013-05-01

    Segmental fixation improves fusion rates and promotes patient mobility by controlling instability after lumbar surgery. Efforts to obtain stability using less invasive techniques have lead to the advent of new implants and constructs. A new interspinous fixation device (ISD) has been introduced as a minimally invasive method of stabilizing two adjacent interspinous processes by augmenting an interbody cage in transforaminal interbody fusion. The ISD is intended to replace the standard pedicle screw instrumentation used for posterior fixation. The purpose of this study is to compare the rigidity of these implant systems when supplementing an interbody cage as used in transforaminal lumbar interbody fusion. An in vitro human cadaveric biomechanical study. Seven human cadaver spines (T12 to the sacrum) were mounted in a custom-designed testing apparatus, for biomechanical testing using a multiaxial robotic system. A comparison of segmental stiffness was carried out among five conditions: intact spine control; interbody spacer (IBS), alone; interbody cage with ISD; IBS, ISD, and unilateral pedicle screws (unilat); and IBS, with bilateral pedicle screws (bilat). An industrial robot (KUKA, GmbH, Augsburg, Germany) applied a pure moment (±5 Nm) in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) through an anchor to the T12 vertebral body. The relative vertebral motion was captured using an optoelectronic camera system (Optotrak; Northern Digital, Inc., Waterloo, Ontario, Canada). The load sensor and the camera were synchronized. Maximum rotation was measured at each level and compared with the intact control. Implant constructs were compared with the control and with each other. A statistical analysis was performed using analysis of variance. A comparison between the intact spine and the IBS group showed no significant difference in the range of motion (ROM) in FE, LB, or AR for the operated level, L3-L4. After implantation of the ISD to augment

  2. Correlation measure to detect time series distances, whence economy globalization

    Science.gov (United States)

    Miśkiewicz, Janusz; Ausloos, Marcel

    2008-11-01

    An instantaneous time series distance is defined through the equal time correlation coefficient. The idea is applied to the Gross Domestic Product (GDP) yearly increments of 21 rich countries between 1950 and 2005 in order to test the process of economic globalisation. Some data discussion is first presented to decide what (EKS, GK, or derived) GDP series should be studied. Distances are then calculated from the correlation coefficient values between pairs of series. The role of time averaging of the distances over finite size windows is discussed. Three network structures are next constructed based on the hierarchy of distances. It is shown that the mean distance between the most developed countries on several networks actually decreases in time, -which we consider as a proof of globalization. An empirical law is found for the evolution after 1990, similar to that found in flux creep. The optimal observation time window size is found ≃15 years.

  3. Lumbosacral interspinous ligament rupture associated with acute intrinsic spinal muscle degeneration

    International Nuclear Information System (INIS)

    Jinkins, Randy J.

    2002-01-01

    The objective of this study was to demonstrate lumbosacral interspinous ligament rupture, with or without related acute intrinsic spinal muscle degeneration. This study consisted of a prospective imaging analysis of consecutive 100 MRI studies in adult patients (mean age 56 years) presenting with low back pain. Alterations from the normal in the inter- and perispinal structures of the spine and perispinal soft tissues (e.g., spinal ligaments, perispinal muscles) were sought based upon studies on young volunteers without low back pain (n=10; mean age 23 years). Compared with the group without low back pain, many index cases (n=71, 71%) demonstrated hyperintensity (i.e., sprain or frank ligamentous rupture) of the interspinous ligament(s) on T2-weighted, fat-suppressed MRI studies at one (20 of 71, 28%) or multiple (51 of 71, 72%) levels. Associated intrinsic spinal muscle (e.g., interspinalis, multifidus muscles) degeneration was observed in a minority of cases overall (n=7, 7%), but was only seen in association with cases also demonstrating interspinous ligament degeneration/rupture (7 of 71, 10%). Lumbosacral interspinous ligament sprain or frank rupture, as well as related acute-subacute autotraumatic intrinsic spinal muscle rupture/degeneration, may be overlooked by many observers if fat-suppressed, T2-weighted MRI is not acquired. These musculoligamentous alterations are on occasion the only abnormalities recognized on MRI of the lumbosacral spine and may theoretically be sources of low back morbidity that potentially may respond to specific therapy. Because this study was an observational one, based solely upon medical imaging, future research must focus upon the correlation of the relevance of these findings with an age-matched asymptomatic control group and longitudinal clinicoradiologic therapeutic trials. (orig.)

  4. Interspinous bursitis is common in polymyalgia rheumatica, but is not associated with spinal pain.

    Science.gov (United States)

    Camellino, Dario; Paparo, Francesco; Morbelli, Silvia; Cutolo, Maurizio; Sambuceti, Gianmario; Cimmino, Marco A

    2014-12-01

    Polymyalgia rheumatica (PMR) is a common inflammatory disease in older people characterized by shoulder and/or pelvic girdle, and cervical and, occasionally, lumbar pain. Interspinous bursitis has been suggested as a potential cause of spinal symptoms. We evaluated, by 18 F-fluorodeoxyglucose (FDG) positron emission tomography integrated with computed tomography (PET/CT), the vertebral structures involved in PMR in a cohort of consecutive, untreated patients. Sixty-five consecutive patients with PMR were studied. After a standardized physical examination, which included evaluation of pain and tenderness in the vertebral column, they underwent FDG-PET/CT. Sites of increased uptake and their correlation with spontaneous and provoked pain were recorded. For comparison, FDG-PET/CT was performed also in 65 age- and sex-matched controls and in 10 rheumatoid arthritis (RA) patients. The most frequent site of spontaneous and provoked pain was the cervical portion. FDG uptake was more frequent in the lumbar portion than at any other location, and in the cervical rather than in the thoracic portion (P bursitis (r = 0.34, P = 0.007). None of the control patients and one out of ten RA patients showed interspinous bursitis. Interspinous bursitis is a frequent finding in the lumbar spine of patients with PMR. However, it is not associated with clinical symptoms and can hardly explain the spinal pain reported by the patients. Cervical pain is more frequent than lumbar pain in PMR patients and may be caused by shoulder girdle involvement.

  5. Distance of Sample Measurement Points to Prototype Catalog Curve

    DEFF Research Database (Denmark)

    Hjorth, Poul G.; Karamehmedovic, Mirza; Perram, John

    2006-01-01

    We discuss strategies for comparing discrete data points to a catalog (reference) curve by means of the Euclidean distance from each point to the curve in a pump's head H vs. flow Qdiagram. In particular we find that a method currently in use is inaccurate. We propose several alternatives...

  6. Pulse EPR distance measurements to study multimers and multimerisation

    Science.gov (United States)

    Ackermann, Katrin; Bode, Bela E.

    2018-06-01

    Pulse dipolar electron paramagnetic resonance (PD-EPR) has become a powerful tool for structural biology determining distances on the nanometre scale. Recent advances in hardware, methodology, and data analysis have widened the scope to complex biological systems. PD-EPR can be applied to systems containing lowly populated conformers or displaying large intrinsic flexibility, making them all but intractable for cryo-electron microscopy and crystallography. Membrane protein applications are of particular interest due to the intrinsic difficulties for obtaining high-resolution structures of all relevant conformations. Many drug targets involved in critical cell functions are multimeric channels or transporters. Here, common approaches for introducing spin labels for PD-EPR cause the presence of more than two electron spins per multimeric complex. This requires careful experimental design to overcome detrimental multi-spin effects and to secure sufficient distance resolution in presence of multiple distances. In addition to obtaining mere distances, PD-EPR can also provide information on multimerisation degrees allowing to study binding equilibria and to determine dissociation constants.

  7. Distance measurement using frequency scanning interferometry with mode-hoped laser

    Science.gov (United States)

    Medhat, M.; Sobee, M.; Hussein, H. M.; Terra, O.

    2016-06-01

    In this paper, frequency scanning interferometry is implemented to measure distances up to 5 m absolutely. The setup consists of a Michelson interferometer, an external cavity tunable diode laser, and an ultra-low expansion (ULE) Fabry-Pérot (FP) cavity to measure the frequency scanning range. The distance is measured by acquiring simultaneously the interference fringes from, the Michelson and the FP interferometers, while scanning the laser frequency. An online fringe processing technique is developed to calculate the distance from the fringe ratio while removing the parts result from the laser mode-hops without significantly affecting the measurement accuracy. This fringe processing method enables accurate distance measurements up to 5 m with measurements repeatability ±3.9×10-6 L. An accurate translation stage is used to find the FP cavity free-spectral-range and therefore allow accurate measurement. Finally, the setup is applied for the short distance calibration of a laser distance meter (LDM).

  8. Measuring the e-Learning Autonomy of Distance Education Students

    Directory of Open Access Journals (Sweden)

    Mehmet Firat

    2016-08-01

    Full Text Available Previous studies have provided evidence that learner autonomy is an important factor in academic achievement. However, few studies have investigated the autonomy of distance education students in e-learning environments. The purpose of this study is to evaluate the e-learning autonomy of distance education students who are responsible for their own learning. For this purpose, as the first step of the study, an e-learning autonomy scale was developed. Analyses of the validity and reliability of the scale were carried out with the participation of 1,152 distance education students from Anadolu University, Open Education System. The scale has an internal consistency coefficient of α = 0.952 and a single factorial model that explains 66.58% of the total variance. The scale was implemented with 3,293 students from 42 different programs. According to the findings, student autonomy in e-learning environments is directly proportional to level of ICT use but not affected by program or gender.

  9. Pairwise Comparison and Distance Measure of Hesitant Fuzzy Linguistic Term Sets

    Directory of Open Access Journals (Sweden)

    Han-Chen Huang

    2014-01-01

    Full Text Available A hesitant fuzzy linguistic term set (HFLTS, allowing experts using several possible linguistic terms to assess a qualitative linguistic variable, is very useful to express people’s hesitancy in practical decision-making problems. Up to now, a little research has been done on the comparison and distance measure of HFLTSs. In this paper, we present a comparison method for HFLTSs based on pairwise comparisons of each linguistic term in the two HFLTSs. Then, a distance measure method based on the pairwise comparison matrix of HFLTSs is proposed, and we prove that this distance is equal to the distance of the average values of HFLTSs, which makes the distance measure much more simple. Finally, the pairwise comparison and distance measure methods are utilized to develop two multicriteria decision-making approaches under hesitant fuzzy linguistic environments. The results analysis shows that our methods in this paper are more reasonable.

  10. Comparison of efficiency of distance measurement methodologies in mango (Mangifera indica) progenies based on physicochemical descriptors.

    Science.gov (United States)

    Alves, E O S; Cerqueira-Silva, C B M; Souza, A M; Santos, C A F; Lima Neto, F P; Corrêa, R X

    2012-03-14

    We investigated seven distance measures in a set of observations of physicochemical variables of mango (Mangifera indica) submitted to multivariate analyses (distance, projection and grouping). To estimate the distance measurements, five mango progeny (total of 25 genotypes) were analyzed, using six fruit physicochemical descriptors (fruit weight, equatorial diameter, longitudinal diameter, total soluble solids in °Brix, total titratable acidity, and pH). The distance measurements were compared by the Spearman correlation test, projection in two-dimensional space and grouping efficiency. The Spearman correlation coefficients between the seven distance measurements were, except for the Mahalanobis' generalized distance (0.41 ≤ rs ≤ 0.63), high and significant (rs ≥ 0.91; P < 0.001). Regardless of the origin of the distance matrix, the unweighted pair group method with arithmetic mean grouping method proved to be the most adequate. The various distance measurements and grouping methods gave different values for distortion (-116.5 ≤ D ≤ 74.5), cophenetic correlation (0.26 ≤ rc ≤ 0.76) and stress (-1.9 ≤ S ≤ 58.9). Choice of distance measurement and analysis methods influence the.

  11. Biomechanical effect of interspinous process distraction height after lumbar fixation surgery: An in vitro model.

    Science.gov (United States)

    Fu, Lin; Ma, Jianxiong; Lu, Bin; Jia, Haobo; Zhao, Jie; Kuang, Mingjie; Feng, Rui; Xu, Liyan; Bai, Haohao; Sun, Lei; Wang, Ying; Ma, Xinlong

    2017-07-01

    Pedicle screw fixation may induce abnormal activity at adjacent segment and accelerate the degeneration of lumbar vertebrae. Dynamic stabilizers could provide an intermediate solution between conservative treatment and fusion surgery. Lumbar vertebral segment cephalad to instrumented fixation was the most common localization of adjacent segment degeneration. The aim of this study is to explore the use of interspinous process devices in the lumbar vertebral segment cephalad to fixation segment in changing the mechanical distribution and limiting abnormal activity of the spine. Eight specimens were tested in the following groups: intact group, instability group (bilateral facetectomy at L3-L4), fixation group (bilateral facetectomy and pedicle screw fixation at L3-L4), and hybrid fixation group (fixation at L3-L4 and simulating interspinous device implantation of 6, 8, 10, 12, 14, 16, and 18 mm at L2-L3). Range of motion, motion of vertebral body, and strain distribution change were recorded. The range of motion in extension with 16- and 18-mm hybrid constructs was significantly lower than intact, instability, and fixation groups. In flexion and lateral bending, the strain values of L4 inferior articular process with 18-mm hybrid construct have a significant difference compared with other groups. In axial rotation, under the condition of a contralateral state, the strain values of L2 superior articular process with 18-mm hybrid construct have a significant difference compared with intact and fixation groups. The strain value of the L4 inferior articular process had negative correlation with height distraction in three dimensions, except extension. A negative correlation between the strain value of the L2 superior articular process and distraction height was found in contralateral bending and contralateral axial rotation. Interspinous process devices above the fixation segment can change the mechanical distribution of the spine and limit activity in some of the

  12. An International Parallax Campaign to Measure Distance to the Moon and Mars

    Science.gov (United States)

    Cenadelli, D.; Zeni, M.; Bernagozzi, A.; Calcidese, P.; Ferreira, L.; Hoang, C.; Rijsdijk, C.

    2009-01-01

    Trigonometric parallax is a powerful method to work out the distance of celestial bodies, and it was used in the past to measure the distance of the Moon, Venus, Mars and nearby stars. We set up an observation campaign for high school and undergraduate students with the purpose to measure both the Moon's and Mars' parallax. To have a large enough…

  13. Air temperature measurements based on the speed of sound to compensate long distance interferometric measurements

    Directory of Open Access Journals (Sweden)

    Astrua Milena

    2014-01-01

    Full Text Available A method to measure the real time temperature distribution along an interferometer path based on the propagation of acoustic waves is presented. It exploits the high sensitivity of the speed of sound in air to the air temperature. In particular, it takes advantage of a special set-up where the generation of the acoustic waves is synchronous with the amplitude modulation of a laser source. A photodetector converts the laser light to an electronic signal considered as reference, while the incoming acoustic waves are focused on a microphone and generate a second signal. In this condition, the phase difference between the two signals substantially depends on the temperature of the air volume interposed between the sources and the receivers. The comparison with the traditional temperature sensors highlighted the limit of the latter in case of fast temperature variations and the advantage of a measurement integrated along the optical path instead of a sampling measurement. The capability of the acoustic method to compensate the interferometric distance measurements due to air temperature variations has been demonstrated for distances up to 27 m.

  14. Intrinsic measurement bias on computed tomography scout view is unpredictable: computed tomography pelvimetry using a phantom

    International Nuclear Information System (INIS)

    Anderson, N.G.; Fenwick, J.L.; Wells, J.E.

    2006-01-01

    Our aim was to determine the degree of bias in CT scanogram measurements. We obtained standard lateral and anteroposterior (AP) pelvimetry scanograms of a phantom pelvis after placing ball bearings or aluminium rods to mark bony landmarks. Computed tomography pelvimetry was carried out at the manufacturer-recommended table height on two commercial CT scanners and at 10-mm increments up to 50 mm above and below this height. The AP inlet, AP outlet, interspinous distance and transverse diameters were each measured three times for each scanogram. The true measurements were obtained directly from the disassembled phantom. Bias was defined as the difference between the CT measurement and the true measurement. Observer error was negligible. The transverse diameter was overestimated at high table positions and underestimated at low table positions on both scanners (+6 to -10 mm). After correcting for geometric distortion, up to 6 mm bias was still present. The point at which no bias occurred was different for each scanner and did not correspond to the manufacturers' recommended table height. The outlet was overestimated on both scanners by up to 5 mm. The true inlet measurement was overestimated by 1.2 mm. The interspinous distance was minimally underestimated on both scanners. The measurements on CT scanogram were underestimated or overestimated in an inconsistent and unpredictable fashion, varying from one type of measurement to another and from CT scanner to CT scanner. This has implications for the accuracy and clinical utility of measurements obtained from a CT scanogram. Copyright (2006) Blackwell Science Pty Ltd

  15. A comparison between using distance sensors for measuring the pantograph vertically movement

    Science.gov (United States)

    Rob, R.; Panoiu, C.; Rusu-Anghel, S.; Panoiu, M.

    2018-01-01

    In railway transportation the most important problem to solve consists in assuring the safety traffic of people and freight. In this scope some of the geometrical parameters regarding the contact line must be measured. One of this parameter is the pantograph vertically movement, so it must use distance sensors. Present paper studies the performance of two kinds of distance sensors, an ultrasonic distance sensor and an infrared sensor. The performances are studied from the point of view of error distance measurement and the possibility of using a real time acquisition system. The researches were made on a laboratory model for the pantograph realized at the scale 1:2.

  16. Measuring the Accuracy of Simple Evolving Connectionist System with Varying Distance Formulas

    Science.gov (United States)

    Al-Khowarizmi; Sitompul, O. S.; Suherman; Nababan, E. B.

    2017-12-01

    Simple Evolving Connectionist System (SECoS) is a minimal implementation of Evolving Connectionist Systems (ECoS) in artificial neural networks. The three-layer network architecture of the SECoS could be built based on the given input. In this study, the activation value for the SECoS learning process, which is commonly calculated using normalized Hamming distance, is also calculated using normalized Manhattan distance and normalized Euclidean distance in order to compare the smallest error value and best learning rate obtained. The accuracy of measurement resulted by the three distance formulas are calculated using mean absolute percentage error. In the training phase with several parameters, such as sensitivity threshold, error threshold, first learning rate, and second learning rate, it was found that normalized Euclidean distance is more accurate than both normalized Hamming distance and normalized Manhattan distance. In the case of beta fibrinogen gene -455 G/A polymorphism patients used as training data, the highest mean absolute percentage error value is obtained with normalized Manhattan distance compared to normalized Euclidean distance and normalized Hamming distance. However, the differences are very small that it can be concluded that the three distance formulas used in SECoS do not have a significant effect on the accuracy of the training results.

  17. A Scale Elasticity Measure for Directional Distance Function and its Dual: Theory and DEA Estimation

    OpenAIRE

    Valentin Zelenyuk

    2012-01-01

    In this paper we focus on scale elasticity measure based on directional distance function for multi-output-multi-input technologies, explore its fundamental properties and show its equivalence with the input oriented and output oriented scale elasticity measures. We also establish duality relationship between the scale elasticity measure based on the directional distance function with scale elasticity measure based on the profit function. Finally, we discuss the estimation issues of the scale...

  18. A Scale Elasticity Measure for Directional Distance Function and its Dual

    OpenAIRE

    Valentin Zelenyuk

    2011-01-01

    In this paper we introduce a scale elasticity measure based on directional distance function for multi-output-multi-input technologies and explore its fundamental properties. Specifically, we derive necessary and sufficient condition for equivalence of the scale elasticity measure based on the directional distance function with the input oriented and output oriented scale elasticity measures. We also establish duality relationship between the scale elasticity measure based on the directional ...

  19. Correlation of Spatially Filtered Dynamic Speckles in Distance Measurement Application

    International Nuclear Information System (INIS)

    Semenov, Dmitry V.; Nippolainen, Ervin; Kamshilin, Alexei A.; Miridonov, Serguei V.

    2008-01-01

    In this paper statistical properties of spatially filtered dynamic speckles are considered. This phenomenon was not sufficiently studied yet while spatial filtering is an important instrument for speckles velocity measurements. In case of spatial filtering speckle velocity information is derived from the modulation frequency of filtered light power which is measured by photodetector. Typical photodetector output is represented by a narrow-band random noise signal which includes non-informative intervals. Therefore more or less precious frequency measurement requires averaging. In its turn averaging implies uncorrelated samples. However, conducting research we found that correlation is typical property not only of dynamic speckle patterns but also of spatially filtered speckles. Using spatial filtering the correlation is observed as a response of measurements provided to the same part of the object surface or in case of simultaneously using several adjacent photodetectors. Found correlations can not be explained using just properties of unfiltered dynamic speckles. As we demonstrate the subject of this paper is important not only from pure theoretical point but also from the point of applied speckle metrology. E.g. using single spatial filter and an array of photodetector can greatly improve accuracy of speckle velocity measurements

  20. [Automated measurement of distance vision based on the DIN strategy].

    Science.gov (United States)

    Effert, R; Steinmetz, H; Jansen, W; Rau, G; Reim, M

    1989-07-01

    A method for automated measurement of far vision is described which meets the test requirements laid down in the new DIN standards. The subject sits 5 m from a high-resolution monitor on which either Landolt rings or Snellen's types are generated by a computer. By moving a joystick the subject indicates to the computer whether he can see the critical detail (e.g., the direction of opening of the Landolt ring). Depending on the subject's input and the course of the test so far, the computer generates the next test symbol until the threshold criterion is reached. The sequence of presentation of the symbols and the threshold criterion are also in accordance with the DIN standard. Initial measurements of far vision using this automated system produced similar results to those obtained by conventional methods.

  1. INTERSPINOUS SPACER IN PERSISTENT DISCOGENIC PAIN: PERCUTANEOUS APPROACH OR OPEN TECHNIQUE

    Directory of Open Access Journals (Sweden)

    José Antonio Cruz Ricardez

    Full Text Available ABSTRACT Objective: To compare the postoperative clinical course of placement of interspinous spacer with open technique (ISO with percutaneous interspinous spacer (PIS. Methods: Quasi-experimental, longitudinal study of 42 patients with discogenic pain uncontrolled with analgesics, aged 35-55 years old, 21 women, and 21 men. Clinical history, location of pain, VAS scale before and after surgery, Oswestry Disability Index and Macnab modified scale at 6 months were used. Results: When performing quantitative analysis statistical significance (p = 0.0478, 0.0466, 0.0399 was demonstrated with Student's t test between the results according to VAS scale; in the qualitative analysis with the Oswestry index and Macnab modified scale it was demonstrated the hypothesis that the results is dependent of the surgical technique. Conclusions: According to the results, we can conclude that there is a statistically significant difference depending on the surgical technique used with respect to the rate of disability and functionality in daily life as well as in the improvement of pain symptoms.

  2. Dynamic frequency-domain interferometer for absolute distance measurements with high resolution

    International Nuclear Information System (INIS)

    Weng, Jidong; Liu, Shenggang; Ma, Heli; Tao, Tianjiong; Wang, Xiang; Liu, Cangli; Tan, Hua

    2014-01-01

    A unique dynamic frequency-domain interferometer for absolute distance measurement has been developed recently. This paper presents the working principle of the new interferometric system, which uses a photonic crystal fiber to transmit the wide-spectrum light beams and a high-speed streak camera or frame camera to record the interference stripes. Preliminary measurements of harmonic vibrations of a speaker, driven by a radio, and the changes in the tip clearance of a rotating gear wheel show that this new type of interferometer has the ability to perform absolute distance measurements both with high time- and distance-resolution

  3. Dynamic frequency-domain interferometer for absolute distance measurements with high resolution

    Science.gov (United States)

    Weng, Jidong; Liu, Shenggang; Ma, Heli; Tao, Tianjiong; Wang, Xiang; Liu, Cangli; Tan, Hua

    2014-11-01

    A unique dynamic frequency-domain interferometer for absolute distance measurement has been developed recently. This paper presents the working principle of the new interferometric system, which uses a photonic crystal fiber to transmit the wide-spectrum light beams and a high-speed streak camera or frame camera to record the interference stripes. Preliminary measurements of harmonic vibrations of a speaker, driven by a radio, and the changes in the tip clearance of a rotating gear wheel show that this new type of interferometer has the ability to perform absolute distance measurements both with high time- and distance-resolution.

  4. Effectiveness of interspinous implant surgery in patients with intermittent neurogenic claudication : a systematic review and meta-analysis

    NARCIS (Netherlands)

    Moojen, Wouter A.; Arts, Mark P.; Bartels, Ronald H. M. A.; Jacobs, Wilco C. H.; Peul, Wilco C.

    2011-01-01

    Despite an increasing implantation rate of interspinous process distraction (IPD) devices in the treatment of intermittent neurogenic claudication (INC), definitive evidence on the clinical effectiveness of implants is lacking. The main objective of this review was to perform a meta-analysis of all

  5. Inductive Contactless Distance Measurement Intended for a Gastric Electrical Implant

    Directory of Open Access Journals (Sweden)

    J. Tomek

    2007-01-01

    Full Text Available For a gastric electrical stimulation project we are developing a system for on-demand switching according to the volume or elongation of the stomach wall. The system is to be implanted into the human abdomen, which limits the utilization of many possible solutions and types of sensors. Magnetic induction has been agreed as the most suitable principle, despite its direction dependency and the need of multi-axial and multiple probes for precision measurements. Possible configurations are discussed as well as the complexity of the necessary electronics and the implantation itself. For detecting food consumption, perfect precision is fortunately not necessary, but a certain compromise will still be necessary for the final system. A simple two-coil system – a transmitter and receiver and a system with a three-axial coil – have already been realized. The first system has already been successfully tested in-vivo on dogs by our US colleagues. However, if the implantation is badly performed, and the coils are completely out of axis, the system cannot sense relative changes in volume properly. The three-axial sensor presented here eliminates these problems. More complex arrangements emerging from magnetic tracking are discussed, because laboratory studies of stomach movements may require them. 

  6. MEASURING EJECTA VELOCITY IMPROVES TYPE Ia SUPERNOVA DISTANCES

    International Nuclear Information System (INIS)

    Foley, Ryan J.; Kasen, Daniel

    2011-01-01

    We use a sample of 121 spectroscopically normal Type Ia supernovae (SNe Ia) to show that their intrinsic color is correlated with their ejecta velocity, as measured from the blueshift of the Si II λ6355 feature near maximum brightness, v SiII . The SN Ia sample was originally used by Wang et al. to show that the relationship between color excess and peak magnitude, which in the absence of intrinsic color differences describes a reddening law, was different for two subsamples split by v SiII (defined as 'Normal' and 'High Velocity'). We verify this result, but find that the two subsamples have the same reddening law when extremely reddened events (E(B - V)>0.35 mag) are excluded. We also show that (1) the High-Velocity subsample is offset by ∼0.06 mag to the red from the Normal subsample in the (B max - V max )-M V plane, (2) the B max - V max cumulative distribution functions of the two subsamples have nearly identical shapes, but the High-Velocity subsample is offset by ∼0.07 mag to the red in B max - V max , and (3) the bluest High-Velocity SNe Ia are ∼0.10 mag redder than the bluest Normal SNe Ia. Together, this evidence indicates a difference in intrinsic color for the subsamples. Accounting for this intrinsic color difference reduces the scatter in Hubble residuals from 0.190 mag to 0.130 mag for SNe Ia with A V ∼ V found in large SN Ia samples. We explain the correlation between ejecta velocity and color as increased line blanketing in the High-Velocity SNe Ia, causing them to become redder. We discuss some implications of this result, and stress the importance of spectroscopy for future SN Ia cosmology surveys, with particular focus on the design of WFIRST.

  7. Evaluating the impact of distance measures on deforestation simulations in the fluvial landscapes of amazonia.

    Science.gov (United States)

    Salonen, Maria; Maeda, Eduardo Eiji; Toivonen, Tuuli

    2014-10-01

    Land use and land cover change (LUCC) models frequently employ different accessibility measures as a proxy for human influence on land change processes. Here, we simulate deforestation in Peruvian Amazonia and evaluate different accessibility measures as LUCC model inputs. We demonstrate how the selection, and different combinations, of accessibility measures impact simulation results. Out of the individual measures, time distance to market center catches the essential aspects of accessibility in our study area. The most accurate simulation is achieved when time distance to market center is used in association with distance to transport network and additional landscape variables. Although traditional Euclidean measures result in clearly lower simulation accuracy when used separately, the combination of two complementary Euclidean measures enhances simulation accuracy significantly. Our results highlight the need for site and context sensitive selection of accessibility variables. More sophisticated accessibility measures can potentially improve LUCC models' spatial accuracy, which often remains low.

  8. A Relative-Localization Algorithm Using Incomplete Pairwise Distance Measurements for Underwater Applications

    Directory of Open Access Journals (Sweden)

    Kae Y. Foo

    2010-01-01

    Full Text Available The task of localizing underwater assets involves the relative localization of each unit using only pairwise distance measurements, usually obtained from time-of-arrival or time-delay-of-arrival measurements. In the fluctuating underwater environment, a complete set of pair-wise distance measurements can often be difficult to acquire, thus hindering a straightforward closed-form solution in deriving the assets' relative coordinates. An iterative multidimensional scaling approach is presented based upon a weighted-majorization algorithm that tolerates missing or inaccurate distance measurements. Substantial modifications are proposed to optimize the algorithm, while the effects of refractive propagation paths are considered. A parametric study of the algorithm based upon simulation results is shown. An acoustic field-trial was then carried out, presenting field measurements to highlight the practical implementation of this algorithm.

  9. Reliability of linear distance measurement for dental implant length with standardized periapical radiographs

    International Nuclear Information System (INIS)

    Wakoh, Mamoru; Harada, Takuya; Otonari, Takamichi

    2006-01-01

    The purpose of this study was to investigate the accuracy of distance measurements of implant length based on periapical radiographs compared with that of other modalities. We carried out an experimental trial to compare precision in distance measurement. Dental implant fixtures were buried in the canine and first molar regions. These were then subjected to periapical (PE) radiography, panoramic (PA) radiography conventional (CV) and medical computed (CT) tomography. The length of the implant fixture on each film was measured by nine observers and degree of precision was statistically analyzed. The precision of both PE radiographs and CT tomograms was closest at the highest level. Standardized PE radiography, in particular, was superior to CT tomography in the first molar region. This suggests that standardized PE radiographs should be utilized as a reliable modality for longitudinal and linear distance measurement, depending on implant length at local implantation site. (author)

  10. How the Measurement of Store Choice Behaviour Moderates the Relationship between Distance and Store Choice Behaviour

    DEFF Research Database (Denmark)

    Hansen, Torben; Cumberland, Flemming; Solgaard, Hans Stubbe

    2013-01-01

    The influence of distance on consumer store choice behaviour has been considered in many studies. In that respect, frequency and budget share are frequently used methods of measurement to determine the consumer's store choice behavour. In this study, we propose that the significance of distance...... is influenced by the way in which store choice behaviour is conceptualized. A survey among 631 consuemrs was performed in order to examine the research proposition. Structural equation results suggest that the negative effect of distance on store choice behaviour is larger when store choice behaviour...... is measured as number of visits to a particular store than wehen store cjoice behaviour is measured as the percentage of budget spend at a particular store. Our results indicate that researchers should carefully consider the measurement of store choice behaviour when carrying out empirical research invlving...

  11. Absolute distance measurement with extension of nonambiguity range using the frequency comb of a femtosecond laser

    Science.gov (United States)

    Jang, Yoon-Soo; Lee, Keunwoo; Han, Seongheum; Lee, Joohyung; Kim, Young-Jin; Kim, Seung-Woo

    2014-12-01

    We revisit the method of synthetic wavelength interferometry (SWI) for absolute measurement of long distances using the radio-frequency harmonics of the pulse repetition rate of a mode-locked femtosecond laser. Our intention here is to extend the nonambiguity range (NAR) of the SWI method using a coarse virtual wavelength synthesized by shifting the pulse repetition rate. The proposed concept of NAR extension is experimentally verified by measuring a ˜13-m distance with repeatability of 9.5 μm (root-mean-square). The measurement precision is estimated to be 31.2 μm in comparison with an incremental He-Ne laser interferometer. This extended SWI method is found to be well suited for long-distance measurements demanded in the fields of large-scale precision engineering, geodetic survey, and future space missions.

  12. Laser distance measurement using a newly developed composite-type optical fiberscope for fetoscopic laser surgery

    Science.gov (United States)

    Seki, Takeshi; Oka, Kiyoshi; Naganawa, Akihiro; Yamashita, Hiromasa; Kim, Keri; Chiba, Toshio

    2010-10-01

    Twin-twin transfusion syndrome (TTTS) is a condition of twins disproportionately sharing blood by the communicating vessels in the shared placenta and resulting in the significantly high fetal and perinatal mortality rate. Fetoscopic laser surgery is performed to block these communicating vessels. It is difficult, however, to perceive the distance from the tip of the fetoscope to the placental surface with only a two-dimensional fetoscopic view. When the distance is too short it causes excessive irradiation and even the risk of inadvertent damage to the placenta. On the other hand, not only target vessels but also adjacent tissues can be irradiated when it is too long. We have developed a composite-type optical fiberscope (COF) that was able to observe the target area and also to perform laser irradiation at the same time. In this paper, we studied a method to estimate the distance from the tip of the COF to the target area. We combined the COF with a laser blood-flow meter. Using laser light from the meter, we measured the total amount of light received ("REFLEX") and estimated the relation between the "REFLEX" value and the laser irradiation distance. Further in vivo experiments were subsequently carried out using porcine mesenteric blood vessels. The results showed that the distance and the "REFLEX" value were inversely proportional, irrespective of the experimental environment (e.g. in air, water and amniotic fluid-like solution) and the target object. In the in vivo experiments, we quantitatively measured the distance within an accuracy of ±1 mm (approximately 10%). In conclusion, our new system was able to measure the distance in vivo enabling a surgeon to safely and effectively perform laser irradiation at a suitable distance. The system can be used not only for fetoscopic surgery but also for general endoscopic surgery.

  13. Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers

    NARCIS (Netherlands)

    Miles, J.E.; Jensen, B.R.; Kirpensteijn, J.; Svalastoga, E.L.; Eriksen, T.

    2013-01-01

    Abstract OBJECTIVE: To describe CT image reconstruction criteria for measurement of the tibial tuberosity-trochlear groove (TT-TG) offset distance, evaluate intra- and inter-reconstruction repeatability, and identify key sources of error in the measurement technique, as determined in vulpine hind

  14. Automation by microcomputer of a geodetic distance measuring instrument: The distinvar

    International Nuclear Information System (INIS)

    Bain, G.; Bore, C.; Coosemans, W.; Dupont, J.; Fabre, J.P.; Gavaggio, R.; Peron, F.

    1985-01-01

    The distinvar is an instrument for the precision measurement of distances up to 50 m. This report describes the latest developments at CERN which have improved its resolution to 2 μm and increased its speed of use. Measurements are automated by incorporating a microcomputer programmed in BASIC. (orig.)

  15. Automation by microprocessor of an geodesic distance measuring instrument: The distinvar

    International Nuclear Information System (INIS)

    Bain, G.; Bore, C.; Coosemans, W.; Dupont, J.; Fabre, J.P.; Gavaggio, R.; Peron, F.

    1984-01-01

    The distinvar is an instrument for the precision measurement of distances up to 50 m. This report describes the latest developments at CERN which have improved its resolution to 2 micrometers and increased its speed of use. Measurements are automated by incorporating a microcomputer programmed in BASIC. (orig.)

  16. Measuring the Dust Grains and Distance to X Persei Via Its X-ray Halo

    Science.gov (United States)

    Smith, Randall

    2006-09-01

    We propose to observe the X-ray halo of the high mass X-ray binary pulsar X Per to measure interstellar dust grains along the line of sight (LOS) and to determine the distance to X Per. The X-ray halo is formed by scattering from grains along the LOS, which for X Per appear to be concentrated in one molecular cloud. Unlike many other X-ray halo observations, this low-absorption high-latitude sightline is well-characterized from absorption spectroscopy done with HST, Copernicus, and FUSE. This halo observation will measure the distance to the cloud and the dust size distribution in it. We will also be able to determine the distance to X Per by measuring the time delayed pulses in the X-ray halo.

  17. Evaluation of gene-expression clustering via mutual information distance measure

    Directory of Open Access Journals (Sweden)

    Maimon Oded

    2007-03-01

    Full Text Available Abstract Background The definition of a distance measure plays a key role in the evaluation of different clustering solutions of gene expression profiles. In this empirical study we compare different clustering solutions when using the Mutual Information (MI measure versus the use of the well known Euclidean distance and Pearson correlation coefficient. Results Relying on several public gene expression datasets, we evaluate the homogeneity and separation scores of different clustering solutions. It was found that the use of the MI measure yields a more significant differentiation among erroneous clustering solutions. The proposed measure was also used to analyze the performance of several known clustering algorithms. A comparative study of these algorithms reveals that their "best solutions" are ranked almost oppositely when using different distance measures, despite the found correspondence between these measures when analysing the averaged scores of groups of solutions. Conclusion In view of the results, further attention should be paid to the selection of a proper distance measure for analyzing the clustering of gene expression data.

  18. Interspinöse Implantate in der Wirbelsäulenchirurgie - eine Frage der Indikation: Ein Fallbericht

    Directory of Open Access Journals (Sweden)

    Decristoforo I

    2009-01-01

    Full Text Available Ein 77-jähriger Patient war wegen manifester neurogener Claudicatio spinalis bei bekannter lumbaler Spinalkanalstenose in 3 Segmenten an einer auswärtigen Institution mit perkutanen interspinösen Implantaten versorgt worden, wonach sich die klinische Symptomatik nicht änderte. Erst die mikrochirurgische Dekompression und die Entfernung der Platzhalter führten zu einer deutlichen Besserung der Beschwerden und Verlängerung der schmerzfreien Gehstrecke. Anhand dieses Falles wird die Verwendung von interspinösen Platzhaltern beleuchtet. In der bisherigen klinischen Anwendung fehlen noch die Langzeitergebnisse. Eine korrekte Indikationsstellung zur Intervention bei Spinalkanalstenose ist Voraussetzung für ein zufriedenstellendes postoperatives Ergebnis.

  19. The Czech national long distances measuring standard Koštice - State of play

    Directory of Open Access Journals (Sweden)

    Ladislav Červinka

    2009-11-01

    Full Text Available This article gives information about new Czech national long distances measuring standard, which has been preparedat the distance base near the Koštice village. Submitter of the project is the Czech Office for Standards, Metrology and Testing.Research and document preparation for creation of the measuring standard were ensured by the Research Institute of Geodesy,Topography and Cartography. Interlaboratory comparisons were made by staff of the Bundeswehr University in Munich. The paperreports about works, which will be carried out on national standard in the second half of this year. Purpose of this works is to improvecharacteristics of accuracy of national etalon.

  20. Absolute distance measurement with correction of air refractive index by using two-color dispersive interferometry.

    Science.gov (United States)

    Wu, Hanzhong; Zhang, Fumin; Liu, Tingyang; Li, Jianshuang; Qu, Xinghua

    2016-10-17

    Two-color interferometry is powerful for the correction of the air refractive index especially in the turbulent air over long distance, since the empirical equations could introduce considerable measurement uncertainty if the environmental parameters cannot be measured with sufficient precision. In this paper, we demonstrate a method for absolute distance measurement with high-accuracy correction of air refractive index using two-color dispersive interferometry. The distances corresponding to the two wavelengths can be measured via the spectrograms captured by a CCD camera pair in real time. In the long-term experiment of the correction of air refractive index, the experimental results show a standard deviation of 3.3 × 10-8 for 12-h continuous measurement without the precise knowledge of the environmental conditions, while the variation of the air refractive index is about 2 × 10-6. In the case of absolute distance measurement, the comparison with the fringe counting interferometer shows an agreement within 2.5 μm in 12 m range.

  1. Clustering by Partitioning around Medoids using Distance-Based Similarity Measures on Interval-Scaled Variables

    Directory of Open Access Journals (Sweden)

    D. L. Nkweteyim

    2018-03-01

    Full Text Available It is reported in this paper, the results of a study of the partitioning around medoids (PAM clustering algorithm applied to four datasets, both standardized and not, and of varying sizes and numbers of clusters. The angular distance proximity measure in addition to the two more traditional proximity measures, namely the Euclidean distance and Manhattan distance, was used to compute object-object similarity. The data used in the study comprise three widely available datasets, and one that was constructed from publicly available climate data. Results replicate some of the well known facts about the PAM algorithm, namely that the quality of the clusters generated tend to be much better for small datasets, that the silhouette value is a good, even if not perfect, guide for the optimal number of clusters to generate, and that human intervention is required to interpret generated clusters. Additionally, results also indicate that the angular distance measure, which traditionally has not been widely used in clustering, outperforms both the Euclidean and Manhattan distance metrics in certain situations.

  2. Effectiveness of interspinous implant surgery in patients with intermittent neurogenic claudication: a systematic review and meta-analysis

    OpenAIRE

    Moojen, Wouter A.; Arts, Mark P.; Bartels, Ronald H. M. A.; Jacobs, Wilco C. H.; Peul, Wilco C.

    2011-01-01

    Introduction Despite an increasing implantation rate of interspinous process distraction (IPD) devices in the treatment of intermittent neurogenic claudication (INC), definitive evidence on the clinical effectiveness of implants is lacking. The main objective of this review was to perform a meta-analysis of all systematic reviews, randomized clinical trials and prospective cohort series to quantify the effectiveness of IPDs and to evaluate the potential side-effects. Methods Data from all stu...

  3. A clinical distance measure for evaluating treatment plan quality difference with Pareto fronts in radiotherapy

    Directory of Open Access Journals (Sweden)

    Kristoffer Petersson

    2017-07-01

    Full Text Available We present a clinical distance measure for Pareto front evaluation studies in radiotherapy, which we show strongly correlates (r = 0.74 and 0.90 with clinical plan quality evaluation. For five prostate cases, sub-optimal treatment plans located at a clinical distance value of >0.32 (0.28–0.35 from fronts of Pareto optimal plans, were assessed to be of lower plan quality by our (12 observers (p < .05. In conclusion, the clinical distance measure can be used to determine if the difference between a front and a given plan (or between different fronts corresponds to a clinically significant plan quality difference.

  4. Geometric measures of quantum correlations: characterization, quantification, and comparison by distances and operations

    International Nuclear Information System (INIS)

    Roga, W; Illuminati, F; Spehner, D

    2016-01-01

    We investigate and compare three distinguished geometric measures of bipartite quantum correlations that have been recently introduced in the literature: the geometric discord, the measurement-induced geometric discord, and the discord of response, each one defined according to three contractive distances on the set of quantum states, namely the trace, Bures, and Hellinger distances. We establish a set of exact algebraic relations and inequalities between the different measures. In particular, we show that the geometric discord and the discord of response based on the Hellinger distance are easy to compute analytically for all quantum states whenever the reference subsystem is a qubit. These two measures thus provide the first instance of discords that are simultaneously fully computable, reliable (since they satisfy all the basic Axioms that must be obeyed by a proper measure of quantum correlations), and operationally viable (in terms of state distinguishability). We apply the general mathematical structure to determine the closest classical-quantum state of a given state and the maximally quantum-correlated states at fixed global state purity according to the different distances, as well as a necessary condition for a channel to be quantumness breaking. (paper)

  5. An uncertainty importance measure using a distance metric for the change in a cumulative distribution function

    International Nuclear Information System (INIS)

    Chun, Moon-Hyun; Han, Seok-Jung; Tak, Nam-IL

    2000-01-01

    A simple measure of uncertainty importance using the entire change of cumulative distribution functions (CDFs) has been developed for use in probability safety assessments (PSAs). The entire change of CDFs is quantified in terms of the metric distance between two CDFs. The metric distance measure developed in this study reflects the relative impact of distributional changes of inputs on the change of an output distribution, while most of the existing uncertainty importance measures reflect the magnitude of relative contribution of input uncertainties to the output uncertainty. The present measure has been evaluated analytically for various analytical distributions to examine its characteristics. To illustrate the applicability and strength of the present measure, two examples are provided. The first example is an application of the present measure to a typical problem of a system fault tree analysis and the second one is for a hypothetical non-linear model. Comparisons of the present result with those obtained by existing uncertainty importance measures show that the metric distance measure is a useful tool to express the measure of uncertainty importance in terms of the relative impact of distributional changes of inputs on the change of an output distribution

  6. In-situ position and vibration measurement of rough surfaces using laser Doppler distance sensors

    Science.gov (United States)

    Czarske, J.; Pfister, T.; Günther, P.; Büttner, L.

    2009-06-01

    In-situ measurement of distances and shapes as well as dynamic deformations and vibrations of fast moving and especially rotating objects, such as gear shafts and turbine blades, is an important task at process control. We recently developed a laser Doppler distance frequency sensor, employing two superposed fan-shaped interference fringe systems with contrary fringe spacing gradients. Via two Doppler frequency evaluations the non-incremental position (i.e. distance) and the tangential velocity of rotating bodies are determined simultaneously. The distance uncertainty is in contrast to e.g. triangulation in principle independent of the object velocity. This unique feature allows micrometer resolutions of fast moved rough surfaces. The novel sensor was applied at turbo machines in order to control the tip clearance. The measurements at a transonic centrifugal compressor were performed during operation at up to 50,000 rpm, i.e. 586 m/s velocity of the blade tips. Due to the operational conditions such as temperatures of up to 300 °C, a flexible and robust measurement system with a passive fiber-coupled sensor, using diffractive optics, has been realized. Since the tip clearance of individual blades could be temporally resolved an analysis of blade vibrations was possible. A Fourier transformation of the blade distances results in an average period of 3 revolutions corresponding to a frequency of 1/3 of the rotary frequency. Additionally, a laser Doppler distance sensor using two tilted fringe systems and phase evaluation will be presented. This phase sensor exhibits a minimum position resolution of σz = 140 nm. It allows precise in-situ shape measurements at grinding and turning processes.

  7. Source-to-detector distance and beam center do not affect radiographic measurements of acetabular morphology

    International Nuclear Information System (INIS)

    Goldman, Ashton H.; Hoover, Kevin B.

    2017-01-01

    Multiple radiographic acquisition techniques have been evaluated for their effect on measurements of acetabular morphology. This cadaveric study examined the effect of two acquisition parameters not previously evaluated: beam center position and source-to-detector distance. This study also evaluated the effect of reader differences on measurements. Following calibration of measurements between two readers using five clinical radiographs (training), radiographs were obtained from two cadavers using four different source-to-detector distances and three different radiographic centers for a total of 12 radiographic techniques (experimental). Two physician readers acquired four types of measurements from each cadaver radiograph: lateral center edge angle, peak-to-edge distance, Sharp's angle, and the Tonnis angle. All measurements were evaluated for intra-class correlation coefficient (ICC), kappa statistics for hip dysplasia, and factors that resulted in measurement differences using a mixed statistical model. After training of the two physician readers, there was strong agreement in their hip morphology measurements (ICC 0.84-0.93), agreement in the presence of hip dysplasia (κ = 0.58-1.0), and no measurement difference between physician readers (p = 0.12-1.0). Experimental cadaver measurements showed moderate-to-strong agreement of the readers (ICC 0.74-0.93) and complete agreement on dysplasia (κ = 1). After accounting for reader and radiographic technique, there was no difference in hip morphology measurements (p = 0.83-0.99). In this cadaveric study, measurements of hip morphology were not affected by varying source-to-detector distance or beam center. We conclude that these acquisition parameters are not likely to affect the diagnosis of hip dysplasia in a clinical setting. (orig.)

  8. Source-to-detector distance and beam center do not affect radiographic measurements of acetabular morphology

    Energy Technology Data Exchange (ETDEWEB)

    Goldman, Ashton H. [Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA (United States); Hoover, Kevin B. [Virginia Commonwealth University, Department of Radiology, 1250 E Marshall St. 3rd Floor, PO Box 980615, Richmond, VA (United States)

    2017-04-15

    Multiple radiographic acquisition techniques have been evaluated for their effect on measurements of acetabular morphology. This cadaveric study examined the effect of two acquisition parameters not previously evaluated: beam center position and source-to-detector distance. This study also evaluated the effect of reader differences on measurements. Following calibration of measurements between two readers using five clinical radiographs (training), radiographs were obtained from two cadavers using four different source-to-detector distances and three different radiographic centers for a total of 12 radiographic techniques (experimental). Two physician readers acquired four types of measurements from each cadaver radiograph: lateral center edge angle, peak-to-edge distance, Sharp's angle, and the Tonnis angle. All measurements were evaluated for intra-class correlation coefficient (ICC), kappa statistics for hip dysplasia, and factors that resulted in measurement differences using a mixed statistical model. After training of the two physician readers, there was strong agreement in their hip morphology measurements (ICC 0.84-0.93), agreement in the presence of hip dysplasia (κ = 0.58-1.0), and no measurement difference between physician readers (p = 0.12-1.0). Experimental cadaver measurements showed moderate-to-strong agreement of the readers (ICC 0.74-0.93) and complete agreement on dysplasia (κ = 1). After accounting for reader and radiographic technique, there was no difference in hip morphology measurements (p = 0.83-0.99). In this cadaveric study, measurements of hip morphology were not affected by varying source-to-detector distance or beam center. We conclude that these acquisition parameters are not likely to affect the diagnosis of hip dysplasia in a clinical setting. (orig.)

  9. Experimental study on performance verification tests for coordinate measuring systems with optical distance sensors

    Science.gov (United States)

    Carmignato, Simone

    2009-01-01

    Optical sensors are increasingly used for dimensional and geometrical metrology. However, the lack of international standards for testing optical coordinate measuring systems is currently limiting the traceability of measurements and the easy comparison of different optical systems. This paper presents an experimental investigation on artefacts and procedures for testing coordinate measuring systems equipped with optical distance sensors. The work is aimed at contributing to the standardization of testing methods. The VDI/VDE 2617-6.2:2005 guideline, which is probably the most complete document available at the state of the art for testing systems with optical distance sensors, is examined with specific experiments. Results from the experiments are discussed, with particular reference to the tests used for determining the following characteristics: error of indication for size measurement, probing error and structural resolution. Particular attention is given to the use of artefacts alternative to gauge blocks for determining the error of indication for size measurement.

  10. A Chroma-based Tempo-insensitive Distance Measure for Cover Song Identification

    DEFF Research Database (Denmark)

    Jensen, Jesper Højvang; Ellis, Dan P. W.; Christensen, Mads Græsbøll

    In the context of music, a cover version is a remake of a song, often with significant stylistic variation. In this paper we describe a distance measure between sampled audio files that is designed to be insensitive to instrumentation, time shift, temporal scaling and transpositions. The algorithm...

  11. Weighted Evidence Combination Rule Based on Evidence Distance and Uncertainty Measure: An Application in Fault Diagnosis

    Directory of Open Access Journals (Sweden)

    Lei Chen

    2018-01-01

    Full Text Available Conflict management in Dempster-Shafer theory (D-S theory is a hot topic in information fusion. In this paper, a novel weighted evidence combination rule based on evidence distance and uncertainty measure is proposed. The proposed approach consists of two steps. First, the weight is determined based on the evidence distance. Then, the weight value obtained in first step is modified by taking advantage of uncertainty. Our proposed method can efficiently handle high conflicting evidences with better performance of convergence. A numerical example and an application based on sensor fusion in fault diagnosis are given to demonstrate the efficiency of our proposed method.

  12. Five-year durability of stand-alone interspinous process decompression for lumbar spinal stenosis

    Directory of Open Access Journals (Sweden)

    Nunley PD

    2017-09-01

    Full Text Available Pierce D Nunley,1 Vikas V Patel,2 Douglas G Orndorff,3 William F Lavelle,4 Jon E Block,5 Fred H Geisler6 1Spine Institute of Louisiana, Shreveport, LA, 2The Spine Center, University of Colorado Hospital, Denver, CO, 3Spine Colorado, Mercy Regional Hospital, Durango, CO, 4Upstate Bone and Joint Center, East Syracuse, NY, 5Independent Consultant, San Francisco, CA, 6Independent Consultant, Chicago, IL, USA Background: Lumbar spinal stenosis is the most common indication for spine surgery in older adults. Interspinous process decompression (IPD using a stand-alone spacer that functions as an extension blocker offers a minimally invasive treatment option for intermittent neurogenic claudication associated with spinal stenosis.Methods: This study evaluated the 5-year clinical outcomes for IPD (Superion® from a randomized controlled US Food and Drug Administration (FDA noninferiority trial. Outcomes included Zurich Claudication Questionnaire (ZCQ symptom severity (ss, physical function (pf, and patient satisfaction (ps subdomains, leg and back pain visual analog scale (VAS, and Oswestry Disability Index (ODI.Results: At 5 years, 84% of patients (74 of 88 demonstrated clinical success on at least two of three ZCQ domains. Individual ZCQ domain success rates were 75% (66 of 88, 81% (71 of 88, and 90% (79 of 88 for ZCQss, ZCQpf, and ZCQps, respectively. Leg and back pain success rates were 80% (68 of 85 and 65% (55 of 85, respectively, and the success rate for ODI was 65% (57 of 88. Percentage improvements over baseline were 42%, 39%, 75%, 66%, and 58% for ZCQss, ZCQpf, leg and back pain VAS, and ODI, respectively (all P<0.001. Within-group effect sizes were classified as very large for four of five clinical outcomes (ie, >1.0; all P<0.0001. Seventy-five percent of IPD patients were free from reoperation, revision, or supplemental fixation at their index level at 5 years.Conclusion: After 5 years of follow-up, IPD with a stand-alone spacer provides

  13. Distance-Based Functional Diversity Measures and Their Decomposition: A Framework Based on Hill Numbers

    Science.gov (United States)

    Chiu, Chun-Huo; Chao, Anne

    2014-01-01

    Hill numbers (or the “effective number of species”) are increasingly used to characterize species diversity of an assemblage. This work extends Hill numbers to incorporate species pairwise functional distances calculated from species traits. We derive a parametric class of functional Hill numbers, which quantify “the effective number of equally abundant and (functionally) equally distinct species” in an assemblage. We also propose a class of mean functional diversity (per species), which quantifies the effective sum of functional distances between a fixed species to all other species. The product of the functional Hill number and the mean functional diversity thus quantifies the (total) functional diversity, i.e., the effective total distance between species of the assemblage. The three measures (functional Hill numbers, mean functional diversity and total functional diversity) quantify different aspects of species trait space, and all are based on species abundance and species pairwise functional distances. When all species are equally distinct, our functional Hill numbers reduce to ordinary Hill numbers. When species abundances are not considered or species are equally abundant, our total functional diversity reduces to the sum of all pairwise distances between species of an assemblage. The functional Hill numbers and the mean functional diversity both satisfy a replication principle, implying the total functional diversity satisfies a quadratic replication principle. When there are multiple assemblages defined by the investigator, each of the three measures of the pooled assemblage (gamma) can be multiplicatively decomposed into alpha and beta components, and the two components are independent. The resulting beta component measures pure functional differentiation among assemblages and can be further transformed to obtain several classes of normalized functional similarity (or differentiation) measures, including N-assemblage functional generalizations of

  14. Distance-based functional diversity measures and their decomposition: a framework based on Hill numbers.

    Directory of Open Access Journals (Sweden)

    Chun-Huo Chiu

    Full Text Available Hill numbers (or the "effective number of species" are increasingly used to characterize species diversity of an assemblage. This work extends Hill numbers to incorporate species pairwise functional distances calculated from species traits. We derive a parametric class of functional Hill numbers, which quantify "the effective number of equally abundant and (functionally equally distinct species" in an assemblage. We also propose a class of mean functional diversity (per species, which quantifies the effective sum of functional distances between a fixed species to all other species. The product of the functional Hill number and the mean functional diversity thus quantifies the (total functional diversity, i.e., the effective total distance between species of the assemblage. The three measures (functional Hill numbers, mean functional diversity and total functional diversity quantify different aspects of species trait space, and all are based on species abundance and species pairwise functional distances. When all species are equally distinct, our functional Hill numbers reduce to ordinary Hill numbers. When species abundances are not considered or species are equally abundant, our total functional diversity reduces to the sum of all pairwise distances between species of an assemblage. The functional Hill numbers and the mean functional diversity both satisfy a replication principle, implying the total functional diversity satisfies a quadratic replication principle. When there are multiple assemblages defined by the investigator, each of the three measures of the pooled assemblage (gamma can be multiplicatively decomposed into alpha and beta components, and the two components are independent. The resulting beta component measures pure functional differentiation among assemblages and can be further transformed to obtain several classes of normalized functional similarity (or differentiation measures, including N-assemblage functional

  15. Revisitation of FRET methods to measure intraprotein distances in Human Serum Albumin

    Energy Technology Data Exchange (ETDEWEB)

    Santini, S.; Bizzarri, A.R.; Cannistraro, S., E-mail: cannistr@unitus.it

    2016-11-15

    We revisited the FRET methods to measure the intraprotein distance between Trp-214 (used as donor) of Human Serum Albumin and its Cys-34, labelled with 1.5-Iaedans (used as acceptor). Variation of Trp fluorescence emission in terms of both intensity and lifetime, as well the enhancement of the acceptor fluorescence emission upon Trp excitation, have been monitored. A careful statistical analysis of the fluorescence results from ten independently prepared samples, combined with suitable spectral corrections, provided reproducible distances estimations by each one of the three methods. Even if monitoring of the donor lifetime variation in the presence of the acceptor reproduces at the best the crystallographic data, by allowing even sub-nanometre distance variations to be appreciated, we suggest that a comparative analysis of all the three methods, applied with statistical significance, should be preferred to achieve a better reliability of the FRET technique.

  16. Measurement of a Cosmographic Distance Ratio with Galaxy and Cosmic Microwave Background Lensing.

    Science.gov (United States)

    Miyatake, Hironao; Madhavacheril, Mathew S; Sehgal, Neelima; Slosar, Anže; Spergel, David N; Sherwin, Blake; van Engelen, Alexander

    2017-04-21

    We measure the gravitational lensing shear signal around dark matter halos hosting constant mass galaxies using light sources at z∼1 (background galaxies) and at the surface of last scattering at z∼1100 (the cosmic microwave background). The galaxy shear measurement uses data from the CFHTLenS survey, and the microwave background shear measurement uses data from the Planck satellite. The ratio of shears from these cross-correlations provides a purely geometric distance measurement across the longest possible cosmological lever arm. This is because the matter distribution around the halos, including uncertainties in galaxy bias and systematic errors such as miscentering, cancels in the ratio for halos in thin redshift slices. We measure this distance ratio in three different redshift slices of the constant mass (CMASS) sample and combine them to obtain a 17% measurement of the distance ratio, r=0.390_{-0.062}^{+0.070}, at an effective redshift of z=0.53. This is consistent with the predicted ratio from the Planck best-fit cold dark matter model with a cosmological constant cosmology of r=0.419.

  17. Recoil distance measurements of litetimes of levels in 2120F and 16N

    International Nuclear Information System (INIS)

    Kozub, R.L.; Mateja, J.F.; Lin, J.; Lister, C.J.; Olness, J.; Warburton, E.K.; Bynum, M.R.; Matthews, T.L.

    1981-01-01

    The previously-reported measurements of meanlives of 20 21 F levels using the recoil-distance method (RDM) and 18 O + 7 Li reactions have been repeated using improved experimental techniques. In addition, the lifetimes of two 16 N levels were measured, using the same experimental setup and 11 B + 7 Li reactions. Data were taken using the BNL precision plunger, in which were mounted a stretched Ta stopper foil (approx. 20 /sub cm 2 //sup mg/ thick) and a 300 μg/cm 2 - thick Li target condensed onto a stretched, 1.4 mg/cm 2 - thick Ta backing. Changes in target-to-stopper distance (d) could be controlled to an accuracy of about +- 1 μm, and were monitored by measuring target-to-stopper capacitance

  18. Recoil distance method lifetime measurements at TRIUMF-ISAC using the TIGRESS Integrated Plunger

    Science.gov (United States)

    Chester, A.; Ball, G. C.; Bernier, N.; Cross, D. S.; Domingo, T.; Drake, T. E.; Evitts, L. J.; Garcia, F. H.; Garnsworthy, A. B.; Hackman, G.; Hallam, S.; Henderson, J.; Henderson, R.; Krücken, R.; MacConnachie, E.; Moukaddam, M.; Padilla-Rodal, E.; Paetkau, O.; Pore, J. L.; Rizwan, U.; Ruotsalainen, P.; Shoults, J.; Smallcombe, J.; Smith, J. K.; Starosta, K.; Svensson, C. E.; Van Wieren, K.; Williams, J.; Williams, M.

    2018-02-01

    The TIGRESS Integrated Plunger device (TIP) has been developed for recoil distance method (RDM) lifetime measurements using the TIGRESS array of HPGe γ-ray detectors at TRIUMF's ISAC-II facility. A commissioning experiment was conducted utilizing a 250 MeV 84Kr beam at ≈ 2 × 108 particles per second. The 84Kr beam was Coulomb excited to the 21+ state on a movable 27Al target. A thin Cu foil fixed downstream from the target was used as a degrader. Excited nuclei emerged from the target and decayed by γ-ray emission at a distance determined by their velocity and the lifetime of the 21+ state. The ratio of decays which occur between the target and degrader to those occurring after traversing the degrader changes as a function of the target-degrader separation distance. Gamma-ray spectra at 13 target-degrader separation distances were measured and compared to simulated lineshapes to extract the lifetime. The result of τ = 5 . 541 ± 0 . 013(stat.) ± 0 . 063(sys.) ps is shorter than the literature value of 5 . 84 ± 0 . 18 ps with a reduction in uncertainty by a factor of approximately two. The TIP plunger device, experimental technique, analysis tools, and result are discussed.

  19. 2H{ 19F} REDOR for distance measurements in biological solids using a double resonance spectrometer

    Science.gov (United States)

    Grage, Stephan L.; Watts, Jude A.; Watts, Anthony

    2004-01-01

    A new approach for distance measurements in biological solids employing 2H{ 19F} rotational echo double resonance was developed and validated on 2H, 19F- D-alanine and an imidazopyridine based inhibitor of the gastric H +/K +-ATPase. The 2H- 19F double resonance experiments presented here were performed without 1H decoupling using a double resonance NMR spectrometer. In this way, it was possible to benefit from the relatively longer distance range of fluorine without the need of specialized fluorine equipment. A distance of 2.5 ± 0.3 Å was measured in the alanine derivative, indicating a gauche conformation of the two labels. In the case of the imidazopyridine compound a lower distance limit of 5.2 Å was determined and is in agreement with an extended conformation of the inhibitor. Several REDOR variants were compared, and their advantages and limitations discussed. Composite fluorine dephasing pulses were found to enhance the frequency bandwidth significantly, and to reduce the dependence of the performance of the experiment on the exact choice of the transmitter frequency.

  20. Superheterodyne configuration for two-wavelength interferometry applied to absolute distance measurement

    International Nuclear Information System (INIS)

    Le Floch, Sebastien; Salvade, Yves; Droz, Nathalie; Mitouassiwou, Rostand; Favre, Patrick

    2010-01-01

    We present a new superheterodyne technique for long-distance measurements by two-wavelength interferometry (TWI). While conventional systems use two acousto-optic modulators to generate two different heterodyne frequencies, here the two frequencies result from synchronized sweeps of optical and radio frequencies. A distributed feedback laser source is injected in an intensity modulator that is driven at the half-wave voltage mode. A radio-frequency signal is applied to this intensity modulator to generate two optical sidebands around the optical carrier. This applied radio frequency consists of a digital ramp between 13 and 15 GHz, with 1 ms duration and with an accuracy of better than 1 ppm. Simultaneously, the laser source is frequency modulated by a current modulation that is synchronized on the radio-frequency ramp as well as on a triangle waveform. These two frequency-swept optical signals at the output of the modulator illuminate a Michelson interferometer and create two distinct distance-dependent heterodyne frequencies on the photodetector. The superheterodyne signal is then detected and bandpass filtered to retrieve the absolute distance measurement. Experiments between 1 and 15 m confirm the validity of this new concept, leading to a distance accuracy of ± 50 μm for a 1 ms acquisition time.

  1. Measurement of distances between anatomical structures using a translating stage with mounted endoscope

    Science.gov (United States)

    Kahrs, Lueder A.; Blachon, Gregoire S.; Balachandran, Ramya; Fitzpatrick, J. Michael; Labadie, Robert F.

    2012-02-01

    During endoscopic procedures it is often desirable to determine the distance between anatomical features. One such clinical application is percutaneous cochlear implantation (PCI), which is a minimally invasive approach to the cochlea via a single, straight drill path and can be achieved accurately using bone-implanted markers and customized microstereotactic frame. During clinical studies to validate PCI, traditional open-field cochlear implant surgery was performed and prior to completion of the surgery, a customized microstereotactic frame designed to achieve the desired PCI trajectory was attached to the bone-implanted markers. To determine whether this trajectory would have safely achieved the target, a sham drill bit is passed through the frame to ensure that the drill bit would reach the cochlea without damaging vital structures. Because of limited access within the facial recess, the distances from the bit to anatomical features could not be measured with calipers. We hypothesized that an endoscope mounted on a sliding stage that translates only along the trajectory, would provide sufficient triangulation to accurately measure these distances. In this paper, the design, fabrication, and testing of such a system is described. The endoscope is mounted so that its optical axis is approximately aligned with the trajectory. Several images are acquired as the stage is moved, and threedimensional reconstruction of selected points allows determination of distances. This concept also has applicability in a large variety of rigid endoscopic interventions including bronchoscopy, laparoscopy, and sinus endoscopy.

  2. Geometric model of pseudo-distance measurement in satellite location systems

    Science.gov (United States)

    Panchuk, K. L.; Lyashkov, A. A.; Lyubchinov, E. V.

    2018-04-01

    The existing mathematical model of pseudo-distance measurement in satellite location systems does not provide a precise solution of the problem, but rather an approximate one. The existence of such inaccuracy, as well as bias in measurement of distance from satellite to receiver, results in inaccuracy level of several meters. Thereupon, relevance of refinement of the current mathematical model becomes obvious. The solution of the system of quadratic equations used in the current mathematical model is based on linearization. The objective of the paper is refinement of current mathematical model and derivation of analytical solution of the system of equations on its basis. In order to attain the objective, geometric analysis is performed; geometric interpretation of the equations is given. As a result, an equivalent system of equations, which allows analytical solution, is derived. An example of analytical solution implementation is presented. Application of analytical solution algorithm to the problem of pseudo-distance measurement in satellite location systems allows to improve the accuracy such measurements.

  3. Distance measurement and wave dispersion in a Liouville-string approach to quantum gravity

    CERN Document Server

    Amelino-Camelia, G; Mavromatos, Nikolaos E; Nanopoulos, Dimitri V

    1997-01-01

    Within a Liouville approach to non-critical string theory, we discuss space-time foam effects on the propagation of low-energy particles. We find an induced frequency-dependent dispersion in the propagation of a wave packet, and observe that this would affect the outcome of measurements involving low-energy particles as probes. In particular, the maximum possible order of magnitude of the space-time foam effects would give rise to an error in the measurement of distance comparable to that independently obtained in some recent heuristic quantum-gravity analyses. We also briefly compare these error estimates with the precision of astrophysical measurements.

  4. Comparison of Travel-Time and Amplitude Measurements for Deep-Focusing Time-Distance Helioseismology

    Science.gov (United States)

    Pourabdian, Majid; Fournier, Damien; Gizon, Laurent

    2018-04-01

    The purpose of deep-focusing time-distance helioseismology is to construct seismic measurements that have a high sensitivity to the physical conditions at a desired target point in the solar interior. With this technique, pairs of points on the solar surface are chosen such that acoustic ray paths intersect at this target (focus) point. Considering acoustic waves in a homogeneous medium, we compare travel-time and amplitude measurements extracted from the deep-focusing cross-covariance functions. Using a single-scattering approximation, we find that the spatial sensitivity of deep-focusing travel times to sound-speed perturbations is zero at the target location and maximum in a surrounding shell. This is unlike the deep-focusing amplitude measurements, which have maximum sensitivity at the target point. We compare the signal-to-noise ratio for travel-time and amplitude measurements for different types of sound-speed perturbations, under the assumption that noise is solely due to the random excitation of the waves. We find that, for highly localized perturbations in sound speed, the signal-to-noise ratio is higher for amplitude measurements than for travel-time measurements. We conclude that amplitude measurements are a useful complement to travel-time measurements in time-distance helioseismology.

  5. Extended VIKOR Method for Intuitionistic Fuzzy Multiattribute Decision-Making Based on a New Distance Measure

    Directory of Open Access Journals (Sweden)

    Xiao Luo

    2017-01-01

    Full Text Available An intuitionistic fuzzy VIKOR (IF-VIKOR method is proposed based on a new distance measure considering the waver of intuitionistic fuzzy information. The method aggregates all individual decision-makers’ assessment information based on intuitionistic fuzzy weighted averaging operator (IFWA, determines the weights of decision-makers and attributes objectively using intuitionistic fuzzy entropy, calculates the group utility and individual regret by the new distance measure, and then reaches a compromise solution. It can be effectively applied to multiattribute decision-making (MADM problems where the weights of decision-makers and attributes are completely unknown and the attribute values are intuitionistic fuzzy numbers (IFNs. The validity and stability of this method are verified by example analysis and sensitivity analysis, and its superiority is illustrated by the comparison with the existing method.

  6. Motor fatigue measurement by distance-induced slow down of walking speed in multiple sclerosis.

    Directory of Open Access Journals (Sweden)

    Rémy Phan-Ba

    Full Text Available BACKGROUND AND RATIONALE: Motor fatigue and ambulation impairment are prominent clinical features of people with multiple sclerosis (pMS. We hypothesized that a multimodal and comparative assessment of walking speed on short and long distance would allow a better delineation and quantification of gait fatigability in pMS. Our objectives were to compare 4 walking paradigms: the timed 25-foot walk (T25FW, a corrected version of the T25FW with dynamic start (T25FW(+, the timed 100-meter walk (T100MW and the timed 500-meter walk (T500MW. METHODS: Thirty controls and 81 pMS performed the 4 walking tests in a single study visit. RESULTS: The 4 walking tests were performed with a slower WS in pMS compared to controls even in subgroups with minimal disability. The finishing speed of the last 100-meter of the T500MW was the slowest measurable WS whereas the T25FW(+ provided the fastest measurable WS. The ratio between such slowest and fastest WS (Deceleration Index, DI was significantly lower only in pMS with EDSS 4.0-6.0, a pyramidal or cerebellar functional system score reaching 3 or a maximum reported walking distance ≤ 4000 m. CONCLUSION: The motor fatigue which triggers gait deceleration over a sustained effort in pMS can be measured by the WS ratio between performances on a very short distance and the finishing pace on a longer more demanding task. The absolute walking speed is abnormal early in MS whatever the distance of effort when patients are unaware of ambulation impairment. In contrast, the DI-measured ambulation fatigability appears to take place later in the disease course.

  7. Fundamental tests and measures of the structure of matter at short distances

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1981-07-01

    Recent progress in gauge field theories has led to a new perspective on the structure of matter and basic interactions at short distances. It is clear that at very high energies quantum electrodynamics, together with the weak and strong interactions, are part of a unified theory with new fundamental constants, new symmetries, and new conservation laws. A non-technical introduction to these topics is given, with emphasis on fundamental tests and measurements. 21 references

  8. Anatomy-Based navigation for ventriculostomy: Nasion-coronal suture distance measurement

    Directory of Open Access Journals (Sweden)

    Mevci Özdemir

    2014-09-01

    Full Text Available Objective: In this study we aimed to determine a landmark that can be measured through the skin with nasal mid-point (bregma to coronal suture, and additionally an average value was calculated. We report, to our knowledge, the distance between the nasion-coronal sutures is reported for the first time in Turkish population. Methods: The study included 30 craniums and 30 frontal bones. Each skull from midline nasal suture to coronal suture curved up at the distance was measured with tape measure. Results: Mean values were determined. Nasal suture between coronal suture distance average 12,2 cm (min10,3 cm, up to 13,5 cm were detected. Conclusion: Nasal suture is an easily palpable area through the skin. A small incision is carried down through skin to bone at the spot 12 cm back from the nasion 3 cm lateral to the midline for ventricular drainage operation. This data provide practical information for neurosurgeon and is available everywhere. J Clin Exp Invest 2014; 5 (3: 368-370

  9. Real-Time and Meter-Scale Absolute Distance Measurement by Frequency-Comb-Referenced Multi-Wavelength Interferometry

    Directory of Open Access Journals (Sweden)

    Guochao Wang

    2018-02-01

    Full Text Available We report on a frequency-comb-referenced absolute interferometer which instantly measures long distance by integrating multi-wavelength interferometry with direct synthetic wavelength interferometry. The reported interferometer utilizes four different wavelengths, simultaneously calibrated to the frequency comb of a femtosecond laser, to implement subwavelength distance measurement, while direct synthetic wavelength interferometry is elaborately introduced by launching a fifth wavelength to extend a non-ambiguous range for meter-scale measurement. A linearity test performed comparatively with a He–Ne laser interferometer shows a residual error of less than 70.8 nm in peak-to-valley over a 3 m distance, and a 10 h distance comparison is demonstrated to gain fractional deviations of ~3 × 10−8 versus 3 m distance. Test results reveal that the presented absolute interferometer enables precise, stable, and long-term distance measurements and facilitates absolute positioning applications such as large-scale manufacturing and space missions.

  10. Real-Time and Meter-Scale Absolute Distance Measurement by Frequency-Comb-Referenced Multi-Wavelength Interferometry.

    Science.gov (United States)

    Wang, Guochao; Tan, Lilong; Yan, Shuhua

    2018-02-07

    We report on a frequency-comb-referenced absolute interferometer which instantly measures long distance by integrating multi-wavelength interferometry with direct synthetic wavelength interferometry. The reported interferometer utilizes four different wavelengths, simultaneously calibrated to the frequency comb of a femtosecond laser, to implement subwavelength distance measurement, while direct synthetic wavelength interferometry is elaborately introduced by launching a fifth wavelength to extend a non-ambiguous range for meter-scale measurement. A linearity test performed comparatively with a He-Ne laser interferometer shows a residual error of less than 70.8 nm in peak-to-valley over a 3 m distance, and a 10 h distance comparison is demonstrated to gain fractional deviations of ~3 × 10 -8 versus 3 m distance. Test results reveal that the presented absolute interferometer enables precise, stable, and long-term distance measurements and facilitates absolute positioning applications such as large-scale manufacturing and space missions.

  11. Characterization of the spatial structure of local functional connectivity using multi-distance average correlation measures.

    Science.gov (United States)

    Macia, Didac; Pujol, Jesus; Blanco-Hinojo, Laura; Martínez-Vilavella, Gerard; Martín-Santos, Rocío; Deus, Joan

    2018-04-24

    There is ample evidence from basic research in neuroscience of the importance of local cortico-cortical networks. Millimetric resolution is achievable with current functional MRI (fMRI) scanners and sequences, and consequently a number of "local" activity similarity measures have been defined to describe patterns of segregation and integration at this spatial scale. We have introduced the use of Iso-Distant local Average Correlation (IDAC), easily defined as the average fMRI temporal correlation of a given voxel with other voxels placed at increasingly separated iso-distant intervals, to characterize the curve of local fMRI signal similarities. IDAC curves can be statistically compared using parametric multivariate statistics. Furthermore, by using RGB color-coding to display jointly IDAC values belonging to three different distance lags, IDAC curves can also be displayed as multi-distance IDAC maps. We applied IDAC analysis to a sample of 41 subjects scanned under two different conditions, a resting state and an auditory-visual continuous stimulation. Multi-distance IDAC mapping was able to discriminate between gross anatomo-functional cortical areas and, moreover, was sensitive to modulation between the two brain conditions in areas known to activate and de-activate during audio-visual tasks. Unlike previous fMRI local similarity measures already in use, our approach draws special attention to the continuous smooth pattern of local functional connectivity.

  12. Radioactive means for measuring distance intervals between anomalies in an earth formation

    International Nuclear Information System (INIS)

    Sandier, G.; Nels, J.P.

    1975-01-01

    In earth formation measurements an investigating tool having a first and a second detector at a relatively small spacing from each other and a third detector at a relatively great spacing from the first and second detectors is moved through a borehole having anomalies such as radioactive bullets or casing joints which are relatively uniformly spaced from each other by a distance which is of the order of said great spacing between the third detector and the first and the second detectors. The first and second detectors generate detection signal peaks for the same anomaly within a short time interval, and the third detector generates a detection signal peak for an adjacent anomaly at about the same time. By means of a defined apparatus, electrical signals representing the times of occurrence of the detection signal peaks from the first and second detectors for the same anomaly and the known small spacing between these detectors are used to obtain an electrical signal for the speed of the investigating tool at that time, and at least some of these electrical signals are combined with electrical signals representing the time of occurrence of the detection signal peak from the third detector for an adjacent anomaly and at least one of the known distances between the detectors to thereby obtain an accurate measure of the distance interval between the pair of adjacent anomalies. (U.S.)

  13. Long-distance measurement-device-independent quantum key distribution with coherent-state superpositions.

    Science.gov (United States)

    Yin, H-L; Cao, W-F; Fu, Y; Tang, Y-L; Liu, Y; Chen, T-Y; Chen, Z-B

    2014-09-15

    Measurement-device-independent quantum key distribution (MDI-QKD) with decoy-state method is believed to be securely applied to defeat various hacking attacks in practical quantum key distribution systems. Recently, the coherent-state superpositions (CSS) have emerged as an alternative to single-photon qubits for quantum information processing and metrology. Here, in this Letter, CSS are exploited as the source in MDI-QKD. We present an analytical method that gives two tight formulas to estimate the lower bound of yield and the upper bound of bit error rate. We exploit the standard statistical analysis and Chernoff bound to perform the parameter estimation. Chernoff bound can provide good bounds in the long-distance MDI-QKD. Our results show that with CSS, both the security transmission distance and secure key rate are significantly improved compared with those of the weak coherent states in the finite-data case.

  14. Accuracy of Positioning Autonomous Biomimetic Underwater Vehicle Using Additional Measurement of Distances

    Directory of Open Access Journals (Sweden)

    Naus Krzysztof

    2016-12-01

    Full Text Available The article describes a study of problem of estimating the position coordinates of Autonomous Biomimetic Underwater Vehicle (ABUV using two methods: dead reckoning (DR and extended Kalman filter (EKF. In the first part of the paper, navigation system of ABUV is described and scientific problem with underwater positioning is formulated. The main part describes a way of estimating the position coordinates using DR and EKF and a numerical experiment involving motion of ABUV along the predetermined test distance. The final part of the paper contains a comparative statistical analysis of the results, carried out for assessing the accuracy of estimation of the position coordinates using DR and EKF methods. It presents the generalized conclusions from the research and the problems relating to the proper placement of the components of the system measuring distances.

  15. Interferometric 30 m bench for calibrations of 1D scales and optical distance measuring instruments

    International Nuclear Information System (INIS)

    Unkuri, J; Rantanen, A; Manninen, J; Esala, V-P; Lassila, A

    2012-01-01

    During construction of a new metrology building for MIKES, a 30 m interferometric bench was designed. The objective was to implement a straight, stable, adjustable and multifunctional 30 m measuring bench for calibrations. Special attention was paid to eliminating the effects of thermal expansion and inevitable concrete shrinkage. The linear guide, situated on top of a monolithic concrete beam, comprises two parallel round shafts with adjustable fixtures every 1 m. A carriage is moved along the rail and its position is followed by a reference interferometer. Depending on the measurement task, one or two retro-reflectors are fixed on the carriage. A microscope with a CCD camera and a monitor can be used to detect line mark positions on different line standards. When calibrating optical distance measuring instruments, various targets can be fixed to the carriage. For the most accurate measurements an online Abbe-error correction based on simultaneous carriage pitch measurement by a separate laser interferometer is applied. The bench is used for calibrations of machinist scales, tapes, circometers, electronic distance meters, total stations and laser trackers. The estimated expanded uncertainty for 30 m displacement for highest accuracy calibrations is 2.6 µm. (paper)

  16. Cross-population validation of statistical distance as a measure of physiological dysregulation during aging.

    Science.gov (United States)

    Cohen, Alan A; Milot, Emmanuel; Li, Qing; Legault, Véronique; Fried, Linda P; Ferrucci, Luigi

    2014-09-01

    Measuring physiological dysregulation during aging could be a key tool both to understand underlying aging mechanisms and to predict clinical outcomes in patients. However, most existing indices are either circular or hard to interpret biologically. Recently, we showed that statistical distance of 14 common blood biomarkers (a measure of how strange an individual's biomarker profile is) was associated with age and mortality in the WHAS II data set, validating its use as a measure of physiological dysregulation. Here, we extend the analyses to other data sets (WHAS I and InCHIANTI) to assess the stability of the measure across populations. We found that the statistical criteria used to determine the original 14 biomarkers produced diverging results across populations; in other words, had we started with a different data set, we would have chosen a different set of markers. Nonetheless, the same 14 markers (or the subset of 12 available for InCHIANTI) produced highly similar predictions of age and mortality. We include analyses of all combinatorial subsets of the markers and show that results do not depend much on biomarker choice or data set, but that more markers produce a stronger signal. We conclude that statistical distance as a measure of physiological dysregulation is stable across populations in Europe and North America. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. CORSEN, a new software dedicated to microscope-based 3D distance measurements: mRNA-mitochondria distance, from single-cell to population analyses.

    Science.gov (United States)

    Jourdren, Laurent; Delaveau, Thierry; Marquenet, Emelie; Jacq, Claude; Garcia, Mathilde

    2010-07-01

    Recent improvements in microscopy technology allow detection of single molecules of RNA, but tools for large-scale automatic analyses of particle distributions are lacking. An increasing number of imaging studies emphasize the importance of mRNA localization in the definition of cell territory or the biogenesis of cell compartments. CORSEN is a new tool dedicated to three-dimensional (3D) distance measurements from imaging experiments especially developed to access the minimal distance between RNA molecules and cellular compartment markers. CORSEN includes a 3D segmentation algorithm allowing the extraction and the characterization of the cellular objects to be processed--surface determination, aggregate decomposition--for minimal distance calculations. CORSEN's main contribution lies in exploratory statistical analysis, cell population characterization, and high-throughput assays that are made possible by the implementation of a batch process analysis. We highlighted CORSEN's utility for the study of relative positions of mRNA molecules and mitochondria: CORSEN clearly discriminates mRNA localized to the vicinity of mitochondria from those that are translated on free cytoplasmic polysomes. Moreover, it quantifies the cell-to-cell variations of mRNA localization and emphasizes the necessity for statistical approaches. This method can be extended to assess the evolution of the distance between specific mRNAs and other cellular structures in different cellular contexts. CORSEN was designed for the biologist community with the concern to provide an easy-to-use and highly flexible tool that can be applied for diverse distance quantification issues.

  18. Poster - 35: Monitoring patient positioning during deep inspiration breath hold with a distance measuring laser

    International Nuclear Information System (INIS)

    Weston, Mark; Juhasz, Janos

    2016-01-01

    Purpose: The accuracy of treatment delivery for left breast/chest wall patients using deep inspiration breath hold (DIBH) is being monitored using a distance measuring laser (DML) Methods: A commercially available DML (DLS-C15, Dimetix) was mounted behind a Varian TrilogyTM linac. Relative to the machine isocenter, the laser from the beam was offset by 8 cm to the left and by 1 cm in the superior direction. This position was selected because this point is situated on the sternum for the majority of the left breast/chest-wall patients treated at our institution. The Varian Real-Time Positioning Management™ (RPM) guided DIBH treatments at our institution is delivered by placing the system’s tracking block on the patient’s abdomen. The treatment beam is enabled only when the block is in between a predefined abdomen motion range as determined during the CT simulation process. A LabVIEW program was developed to record both beam status (i.e. on/off) and distance measurements. In this study the DML was only used to monitor the position of a single point on the chest and no clinical decisions/adjustments were made based on these measurements. Results and Conclusions: Thus far, 34 fractions have been recorded for 4 patients. As such, the performance of our DIBH treatment technique cannot be fairly evaluated at this point. However, deviations between expected and measured distances have been observed and if these are found to be reproducible, then modifications in our treatment procedures and policies will have to take place.

  19. Poster - 35: Monitoring patient positioning during deep inspiration breath hold with a distance measuring laser

    Energy Technology Data Exchange (ETDEWEB)

    Weston, Mark; Juhasz, Janos [Juravinski Cancer Centre (Canada)

    2016-08-15

    Purpose: The accuracy of treatment delivery for left breast/chest wall patients using deep inspiration breath hold (DIBH) is being monitored using a distance measuring laser (DML) Methods: A commercially available DML (DLS-C15, Dimetix) was mounted behind a Varian TrilogyTM linac. Relative to the machine isocenter, the laser from the beam was offset by 8 cm to the left and by 1 cm in the superior direction. This position was selected because this point is situated on the sternum for the majority of the left breast/chest-wall patients treated at our institution. The Varian Real-Time Positioning Management™ (RPM) guided DIBH treatments at our institution is delivered by placing the system’s tracking block on the patient’s abdomen. The treatment beam is enabled only when the block is in between a predefined abdomen motion range as determined during the CT simulation process. A LabVIEW program was developed to record both beam status (i.e. on/off) and distance measurements. In this study the DML was only used to monitor the position of a single point on the chest and no clinical decisions/adjustments were made based on these measurements. Results and Conclusions: Thus far, 34 fractions have been recorded for 4 patients. As such, the performance of our DIBH treatment technique cannot be fairly evaluated at this point. However, deviations between expected and measured distances have been observed and if these are found to be reproducible, then modifications in our treatment procedures and policies will have to take place.

  20. Lifetime measurements using the recoil distance method—achievements and perspectives

    Science.gov (United States)

    Krücken, R.

    2001-07-01

    The recoil distance method (RDM) for measuring pico-second nuclear level lifetimes and its use in nuclear structure studies is reviewed and perspectives for the future are presented. High precision measurements in the mass-130 region, studies of multi-phonon states in rare earth nuclei, the investigation of shape coexistence and the recently discovered phenomenon of "magnetic rotation" are reviewed. Prospects for lifetime measurements in exotic regions of nuclei such as the measurement of lifetimes in neutron rich nuclei populated via spontaneous and heavy-ion induced fission are discussed. Other prospects include the use of the RDM technique in conjunction with recoil separators. The relevance of these techniques for experiments with radioactive ion beams will be discussed.

  1. Application of digital image correlation for long-distance bridge deflection measurement

    Science.gov (United States)

    Tian, Long; Pan, Bing; Cai, Youfa; Liang, Hui; Zhao, Yan

    2013-06-01

    Due to its advantages of non-contact, full-field and high-resolution measurement, digital image correlation (DIC) method has gained wide acceptance and found numerous applications in the field of experimental mechanics. In this paper, the application of DIC for real-time long-distance bridge deflection detection in outdoor environments is studied. Bridge deflection measurement using DIC in outdoor environments is more challenging than regular DIC measurements performed under laboratory conditions. First, much more image noise due to variations in ambient light will be presented in the images recorded in outdoor environments. Second, how to select the target area becomes a key factor because long-distance imaging results in a large field of view of the test object. Finally, the image acquisition speed of the camera must be high enough (larger than 100 fps) to capture the real-time dynamic motion of a bridge. In this work, the above challenging issues are addressed and several improvements were made to DIC method. The applicability was demonstrated by real experiments. Experimental results indicate that the DIC method has great potentials in motion measurement in various large building structures.

  2. Absolute distance measurement with micrometer accuracy using a Michelson interferometer and the iterative synthetic wavelength principle.

    Science.gov (United States)

    Alzahrani, Khaled; Burton, David; Lilley, Francis; Gdeisat, Munther; Bezombes, Frederic; Qudeisat, Mohammad

    2012-02-27

    We present a novel system that can measure absolute distances of up to 300 mm with an uncertainty of the order of one micrometer, within a timeframe of 40 seconds. The proposed system uses a Michelson interferometer, a tunable laser, a wavelength meter and a computer for analysis. The principle of synthetic wave creation is used in a novel way in that the system employs an initial low precision estimate of the distance, obtained using a triangulation, or time-of-flight, laser system, or similar, and then iterates through a sequence of progressively smaller synthetic wavelengths until it reaches micrometer uncertainties in the determination of the distance. A further novel feature of the system is its use of Fourier transform phase analysis techniques to achieve sub-wavelength accuracy. This method has the major advantages of being relatively simple to realize, offering demonstrated high relative precisions better than 5 × 10(-5). Finally, the fact that this device does not require a continuous line-of-sight to the target as is the case with other configurations offers significant advantages.

  3. Measuring distance through dense weighted networks: The case of hospital-associated pathogens.

    Directory of Open Access Journals (Sweden)

    Tjibbe Donker

    2017-08-01

    Full Text Available Hospital networks, formed by patients visiting multiple hospitals, affect the spread of hospital-associated infections, resulting in differences in risks for hospitals depending on their network position. These networks are increasingly used to inform strategies to prevent and control the spread of hospital-associated pathogens. However, many studies only consider patients that are received directly from the initial hospital, without considering the effect of indirect trajectories through the network. We determine the optimal way to measure the distance between hospitals within the network, by reconstructing the English hospital network based on shared patients in 2014-2015, and simulating the spread of a hospital-associated pathogen between hospitals, taking into consideration that each intermediate hospital conveys a delay in the further spread of the pathogen. While the risk of transferring a hospital-associated pathogen between directly neighbouring hospitals is a direct reflection of the number of shared patients, the distance between two hospitals far-away in the network is determined largely by the number of intermediate hospitals in the network. Because the network is dense, most long distance transmission chains in fact involve only few intermediate steps, spreading along the many weak links. The dense connectivity of hospital networks, together with a strong regional structure, causes hospital-associated pathogens to spread from the initial outbreak in a two-step process: first, the directly surrounding hospitals are affected through the strong connections, second all other hospitals receive introductions through the multitude of weaker links. Although the strong connections matter for local spread, weak links in the network can offer ideal routes for hospital-associated pathogens to travel further faster. This hold important implications for infection prevention and control efforts: if a local outbreak is not controlled in time

  4. Moving gantry method for electron beam dose profile measurement at extended source-to-surface distances.

    Science.gov (United States)

    Fekete, Gábor; Fodor, Emese; Pesznyák, Csilla

    2015-03-08

    A novel method has been put forward for very large electron beam profile measurement. With this method, absorbed dose profiles can be measured at any depth in a solid phantom for total skin electron therapy. Electron beam dose profiles were collected with two different methods. Profile measurements were performed at 0.2 and 1.2 cm depths with a parallel plate and a thimble chamber, respectively. 108cm × 108 cm and 45 cm × 45 cm projected size electron beams were scanned by vertically moving phantom and detector at 300 cm source-to-surface distance with 90° and 270° gantry angles. The profiles collected this way were used as reference. Afterwards, the phantom was fixed on the central axis and the gantry was rotated with certain angular steps. After applying correction for the different source-to-detector distances and incidence of angle, the profiles measured in the two different setups were compared. Correction formalism has been developed. The agreement between the cross profiles taken at the depth of maximum dose with the 'classical' scanning and with the new moving gantry method was better than 0.5 % in the measuring range from zero to 71.9 cm. Inverse square and attenuation corrections had to be applied. The profiles measured with the parallel plate chamber agree better than 1%, except for the penumbra region, where the maximum difference is 1.5%. With the moving gantry method, very large electron field profiles can be measured at any depth in a solid phantom with high accuracy and reproducibility and with much less time per step. No special instrumentation is needed. The method can be used for commissioning of very large electron beams for computer-assisted treatment planning, for designing beam modifiers to improve dose uniformity, and for verification of computed dose profiles.

  5. Measuring Algorithm for the Distance to a Preceding Vehicle on Curve Road Using On-Board Monocular Camera

    Science.gov (United States)

    Yu, Guizhen; Zhou, Bin; Wang, Yunpeng; Wun, Xinkai; Wang, Pengcheng

    2015-12-01

    Due to more severe challenges of traffic safety problems, the Advanced Driver Assistance Systems (ADAS) has received widespread attention. Measuring the distance to a preceding vehicle is important for ADAS. However, the existing algorithm focuses more on straight road sections than on curve measurements. In this paper, we present a novel measuring algorithm for the distance to a preceding vehicle on a curve road using on-board monocular camera. Firstly, the characteristics of driving on the curve road is analyzed and the recognition of the preceding vehicle road area is proposed. Then, the vehicle detection and distance measuring algorithms are investigated. We have verified these algorithms on real road driving. The experimental results show that this method proposed in the paper can detect the preceding vehicle on curve roads and accurately calculate the longitudinal distance and horizontal distance to the preceding vehicle.

  6. Prenatal Triclosan Exposure and Anthropometric Measures Including Anogenital Distance in Danish Infants

    DEFF Research Database (Denmark)

    Lassen, Tina Harmer; Frederiksen, Hanne; Kyhl, Henriette Boye

    2016-01-01

    , Swan SH, Main KM, Andersson AM, Lind DV, Husby S, Wohlfahrt-Veje C, Skakkebæk NE, Jensen TK. 2016. Prenatal triclosan exposure and anthropometric measures including anogenital distance in Danish infants. Environ Health Perspect 124:1261-1268; http://dx.doi.org/10.1289/ehp.1409637.......BACKGROUND: Triclosan (TCS) is widely used as an antibacterial agent in consumer products such as hand soap and toothpaste, and human exposure is widespread. TCS is suspected of having endocrine-disrupting properties, but few human studies have examined the developmental effects of prenatal TCS...

  7. Finding differentially expressed genes in high dimensional data: Rank based test statistic via a distance measure.

    Science.gov (United States)

    Mathur, Sunil; Sadana, Ajit

    2015-12-01

    We present a rank-based test statistic for the identification of differentially expressed genes using a distance measure. The proposed test statistic is highly robust against extreme values and does not assume the distribution of parent population. Simulation studies show that the proposed test is more powerful than some of the commonly used methods, such as paired t-test, Wilcoxon signed rank test, and significance analysis of microarray (SAM) under certain non-normal distributions. The asymptotic distribution of the test statistic, and the p-value function are discussed. The application of proposed method is shown using a real-life data set. © The Author(s) 2011.

  8. Technique for long and absolute distance measurement based on laser pulse repetition frequency sweeping

    Science.gov (United States)

    Castro Alves, D.; Abreu, Manuel; Cabral, A.; Jost, Michael; Rebordão, J. M.

    2017-11-01

    In this work we present a technique to perform long and absolute distance measurements based on mode-locked diode lasers. Using a Michelson interferometer, it is possible to produce an optical cross-correlation between laser pulses of the reference arm with the pulses from the measurement arm, adjusting externally their degree of overlap either changing the pulse repetition frequency (PRF) or the position of the reference arm mirror for two (or more) fixed frequencies. The correlation of the travelling pulses for precision distance measurements relies on ultra-short pulse durations, as the uncertainty associated to the method is dependent on the laser pulse width as well as on a highly stable PRF. Mode-locked Diode lasers are a very appealing technology for its inherent characteristics, associated to compactness, size and efficiency, constituting a positive trade-off with regard to other mode-locked laser sources. Nevertheless, main current drawback is the non-availability of frequency-stable laser diodes. The laser used is a monolithic mode-locked semiconductor quantum-dot (QD) laser. The laser PRF is locked to an external stabilized RF reference. In this work we will present some of the preliminary results and discuss the importance of the requirements related to laser PRF stability in the final metrology system accuracy.

  9. Improved GPS-based Satellite Relative Navigation Using Femtosecond Laser Relative Distance Measurements

    Directory of Open Access Journals (Sweden)

    Hyungjik Oh

    2016-03-01

    Full Text Available This study developed an approach for improving Carrier-phase Differential Global Positioning System (CDGPS based realtime satellite relative navigation by applying laser baseline measurement data. The robustness against the space operational environment was considered, and a Synthetic Wavelength Interferometer (SWI algorithm based on a femtosecond laser measurement model was developed. The phase differences between two laser wavelengths were combined to measure precise distance. Generated laser data were used to improve estimation accuracy for the float ambiguity of CDGPS data. Relative navigation simulations in real-time were performed using the extended Kalman filter algorithm. The GPS and laser-combined relative navigation accuracy was compared with GPS-only relative navigation solutions to determine the impact of laser data on relative navigation. In numerical simulations, the success rate of integer ambiguity resolution increased when laser data was added to GPS data. The relative navigational errors also improved five-fold and two-fold, relative to the GPS-only error, for 250 m and 5 km initial relative distances, respectively. The methodology developed in this study is suitable for application to future satellite formation-flying missions.

  10. NOTE ON TRAVEL TIME SHIFTS DUE TO AMPLITUDE MODULATION IN TIME-DISTANCE HELIOSEISMOLOGY MEASUREMENTS

    International Nuclear Information System (INIS)

    Nigam, R.; Kosovichev, A. G.

    2010-01-01

    Correct interpretation of acoustic travel times measured by time-distance helioseismology is essential to get an accurate understanding of the solar properties that are inferred from them. It has long been observed that sunspots suppress p-mode amplitude, but its implications on travel times have not been fully investigated so far. It has been found in test measurements using a 'masking' procedure, in which the solar Doppler signal in a localized quiet region of the Sun is artificially suppressed by a spatial function, and using numerical simulations that the amplitude modulations in combination with the phase-speed filtering may cause systematic shifts of acoustic travel times. To understand the properties of this procedure, we derive an analytical expression for the cross-covariance of a signal that has been modulated locally by a spatial function that has azimuthal symmetry and then filtered by a phase-speed filter typically used in time-distance helioseismology. Comparing this expression to the Gabor wavelet fitting formula without this effect, we find that there is a shift in the travel times that is introduced by the amplitude modulation. The analytical model presented in this paper can be useful also for interpretation of travel time measurements for the non-uniform distribution of oscillation amplitude due to observational effects.

  11. Fabrication of 94Zr thin target for recoil distance doppler shift method of lifetime measurement

    International Nuclear Information System (INIS)

    Gupta, C.K.; Rohilla, Aman; Abhilash, S.R.; Kabiraj, D.; Singh, R.P.; Mehta, D.; Chamoli, S.K.

    2014-01-01

    A thin isotopic 94 Zr target of thickness 520μg/cm 2 has been prepared for recoil distance Doppler shift method (RDM) lifetime measurement by using an electron beam deposition method on tantalum backing of 3.5 mg/cm 2 thickness at Inter University Accelerator Center (IUAC), New Delhi. To meet the special requirement of smoothness of surface for RDM lifetime measurement and also to protect the outer layer of 94 Zr from peeling off, a very thin layer of gold has been evaporated on a 94 Zr target on a specially designed substrate holder. In all, 143 mg of 99.6% enriched 94 Zr target material was utilized for the fabrication of 94 Zr targets. The target has been successfully used in a recent RDM lifetime measurement experiment at IUAC

  12. Fabrication of 94Zr thin target for recoil distance doppler shift method of lifetime measurement

    Science.gov (United States)

    Gupta, C. K.; Rohilla, Aman; Abhilash, S. R.; Kabiraj, D.; Singh, R. P.; Mehta, D.; Chamoli, S. K.

    2014-11-01

    A thin isotopic 94Zr target of thickness 520 μg /cm2 has been prepared for recoil distance Doppler shift method (RDM) lifetime measurement by using an electron beam deposition method on tantalum backing of 3.5 mg/cm2 thickness at Inter University Accelerator Center (IUAC), New Delhi. To meet the special requirement of smoothness of surface for RDM lifetime measurement and also to protect the outer layer of 94Zr from peeling off, a very thin layer of gold has been evaporated on a 94Zr target on a specially designed substrate holder. In all, 143 mg of 99.6% enriched 94Zr target material was utilized for the fabrication of 94Zr targets. The target has been successfully used in a recent RDM lifetime measurement experiment at IUAC.

  13. Relative distance between tracers as a measure of diffusivity within moving aggregates

    Science.gov (United States)

    Pönisch, Wolfram; Zaburdaev, Vasily

    2018-02-01

    Tracking of particles, be it a passive tracer or an actively moving bacterium in the growing bacterial colony, is a powerful technique to probe the physical properties of the environment of the particles. One of the most common measures of particle motion driven by fluctuations and random forces is its diffusivity, which is routinely obtained by measuring the mean squared displacement of the particles. However, often the tracer particles may be moving in a domain or an aggregate which itself experiences some regular or random motion and thus masks the diffusivity of tracers. Here we provide a method for assessing the diffusivity of tracer particles within mobile aggregates by measuring the so-called mean squared relative distance (MSRD) between two tracers. We provide analytical expressions for both the ensemble and time averaged MSRD allowing for direct identification of diffusivities from experimental data.

  14. Fabrication of {sup 94}Zr thin target for recoil distance doppler shift method of lifetime measurement

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, C.K.; Rohilla, Aman [Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Abhilash, S.R.; Kabiraj, D.; Singh, R.P. [Inter University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110067 (India); Mehta, D. [Department of Physics, Panjab University, Chandigarh 160014 (India); Chamoli, S.K., E-mail: skchamoli@physics.du.ac.in [Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India)

    2014-11-11

    A thin isotopic {sup 94}Zr target of thickness 520μg/cm{sup 2} has been prepared for recoil distance Doppler shift method (RDM) lifetime measurement by using an electron beam deposition method on tantalum backing of 3.5 mg/cm{sup 2} thickness at Inter University Accelerator Center (IUAC), New Delhi. To meet the special requirement of smoothness of surface for RDM lifetime measurement and also to protect the outer layer of {sup 94}Zr from peeling off, a very thin layer of gold has been evaporated on a {sup 94}Zr target on a specially designed substrate holder. In all, 143 mg of 99.6% enriched {sup 94}Zr target material was utilized for the fabrication of {sup 94}Zr targets. The target has been successfully used in a recent RDM lifetime measurement experiment at IUAC.

  15. Comparing alternative approaches to measuring the geographical accessibility of urban health services: Distance types and aggregation-error issues

    Directory of Open Access Journals (Sweden)

    Riva Mylène

    2008-02-01

    Full Text Available Abstract Background Over the past two decades, geographical accessibility of urban resources for population living in residential areas has received an increased focus in urban health studies. Operationalising and computing geographical accessibility measures depend on a set of four parameters, namely definition of residential areas, a method of aggregation, a measure of accessibility, and a type of distance. Yet, the choice of these parameters may potentially generate different results leading to significant measurement errors. The aim of this paper is to compare discrepancies in results for geographical accessibility of selected health care services for residential areas (i.e. census tracts computed using different distance types and aggregation methods. Results First, the comparison of distance types demonstrates that Cartesian distances (Euclidean and Manhattan distances are strongly correlated with more accurate network distances (shortest network and shortest network time distances across the metropolitan area (Pearson correlation greater than 0.95. However, important local variations in correlation between Cartesian and network distances were observed notably in suburban areas where Cartesian distances were less precise. Second, the choice of the aggregation method is also important: in comparison to the most accurate aggregation method (population-weighted mean of the accessibility measure for census blocks within census tracts, accessibility measures computed from census tract centroids, though not inaccurate, yield important measurement errors for 5% to 10% of census tracts. Conclusion Although errors associated to the choice of distance types and aggregation method are only important for about 10% of census tracts located mainly in suburban areas, we should not avoid using the best estimation method possible for evaluating geographical accessibility. This is especially so if these measures are to be included as a dimension of the

  16. Accuracy Improvement of Discharge Measurement with Modification of Distance Made Good Heading

    Directory of Open Access Journals (Sweden)

    Jongkook Lee

    2016-01-01

    Full Text Available Remote control boats equipped with an Acoustic Doppler Current Profiler (ADCP are widely accepted and have been welcomed by many hydrologists for water discharge, velocity profile, and bathymetry measurements. The advantages of this technique include high productivity, fast measurements, operator safety, and high accuracy. However, there are concerns about controlling and operating a remote boat to achieve measurement goals, especially during extreme events such as floods. When performing river discharge measurements, the main error source stems from the boat path. Due to the rapid flow in a flood condition, the boat path is not regular and this can cause errors in discharge measurements. Therefore, improvement of discharge measurements requires modification of boat path. As a result, the measurement errors in flood flow conditions are 12.3–21.8% before the modification of boat path, but 1.2–3.7% after the DMG modification of boat path. And it is considered that the modified discharges are very close to the observed discharge in the flood flow conditions. In this study, through the distance made good (DMG modification of the boat path, a comprehensive discharge measurement with high accuracy can be achieved.

  17. Time domain simulation of Gd3+-Gd3+ distance measurements by EPR

    Science.gov (United States)

    Manukovsky, Nurit; Feintuch, Akiva; Kuprov, Ilya; Goldfarb, Daniella

    2017-07-01

    Gd3+-based spin labels are useful as an alternative to nitroxides for intramolecular distance measurements at high fields in biological systems. However, double electron-electron resonance (DEER) measurements using model Gd3+ complexes featured a low modulation depth and an unexpected broadening of the distance distribution for short Gd3+-Gd3+ distances, when analysed using the software designed for S = 1/2 pairs. It appears that these effects result from the different spectroscopic characteristics of Gd3+—the high spin, the zero field splitting (ZFS), and the flip-flop terms in the dipolar Hamiltonian that are often ignored for spin-1/2 systems. An understanding of the factors affecting the modulation frequency and amplitude is essential for the correct analysis of Gd3+-Gd3+ DEER data and for the educated choice of experimental settings, such as Gd3+ spin label type and the pulse parameters. This work uses time-domain simulations of Gd3+-Gd3+ DEER by explicit density matrix propagation to elucidate the factors shaping Gd3+ DEER traces. The simulations show that mixing between the |+½, -½> and |-½, +½> states of the two spins, caused by the flip-flop term in the dipolar Hamiltonian, leads to dampening of the dipolar modulation. This effect may be mitigated by a large ZFS or by pulse frequency settings allowing for a decreased contribution of the central transition and the one adjacent to it. The simulations reproduce both the experimental line shapes of the Fourier-transforms of the DEER time domain traces and the trends in the behaviour of the modulation depth, thus enabling a more systematic design and analysis of Gd3+ DEER experiments.

  18. New physical examination tests for lumbar spondylolisthesis and instability: low midline sill sign and interspinous gap change during lumbar flexion-extension motion.

    Science.gov (United States)

    Ahn, Kang; Jhun, Hyung-Joon

    2015-04-22

    Lumbar spondylolisthesis (LS) and lumbar instability (LI) are common disorders in patients with low back or lumbar radicular pain. However, few physical examination tests for LS and LI have been reported. In the study described herein, new physical examination tests for LS and LI were devised and evaluated for their validity. The test for LS was designated "low midline sill sign", and that for LI was designated "interspinous gap change" during lumbar flexion-extension motion. The validity of the low midline sill sign was evaluated in 96 patients with low back or lumbar radicular pain. Validity of the interspinous gap change during lumbar flexion-extension motion was evaluated in 73 patients with low back or lumbar radicular pain. The sensitivity, specificity, and positive and negative predictive values of the two tests were also investigated. The sensitivity and specificity of the low midline sill sign for LS were 81.3% and 89.1%, respectively. Positive and negative predictive values of the test were 78.8% and 90.5%, respectively. The sensitivity and specificity of the interspinous gap change test for LI were 82.2% and 60.7%, respectively. Positive and negative predictive values of the test were 77.1% and 68.0%, respectively. The low midline sill sign and interspinous gap change tests are effective for the detection of LS and LI, and can be performed easily in an outpatient setting.

  19. Epidural cystic masses associated with interspinous bursitis, synovial and discal cysts; Formacoes cisticas epidurais relacionadas a bursite interespinhosa, cisto sinovial e cisto discal

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Frederico Guilherme de Paula Lopes; Souza, Ricardo Andre de; Brotto, Marcos Pama D' Almeida; Suguita, Fabio Massaaki; Amaral, Denise Tokechi; Amaral, Lazaro Luis Faria do [Hospital Beneficencia Portuguesa de Sao Paulo, Sao Paulo, SP (Brazil). MedImagem], e-mail: fgpls@yahoo.com.br

    2009-03-15

    The authors describe some cases of epidural cysts, namely synovial, discal, ligamentum flavum cysts, and cysts secondary to interspinous bursitis, all of these conditions determining radicular, dural sac compression or spinal canal stenosis. Magnetic resonance imaging findings and localization of these entities are described. (author)

  20. Application of discriminant analysis and generalized distance measures to uranium exploration

    International Nuclear Information System (INIS)

    Beauchamp, J.J.; Begovich, C.L.; Kane, V.E.; Wolf, D.A.

    1980-01-01

    The National Uranium Resource Evaluation (NURE) Program has as its goal the estimation of the nation's uranium resources. It is possile to use discriminant analysis methods on hydrogeochemical data collected in the NURE Program to aid in fomulating geochemical models that can be used to identify the anomalous areas used in resource estimation. Discriminant' analysis methods have been applied to data from the Plainview, Texas Quadrangle which has approximately 850 groundwater samples with more than 40 quantitative measurements per sample. Discriminant analysis topics involving estimation of misclassification probabilities, variable selection, and robust discrimination are applied. A method using generalized distance measures is given which enables the assignment of samples to a background population or a mineralized population whose parameters were estimated from separate studies. Each topic is related to its relevance in identifying areas of possible interest to uranium exploration. However, the methodology presented here is applicable to the identification of regions associated with other types of resources. 8 figures, 3 tables

  1. Application of discriminant analysis and generalized distance measures to uranium exploration

    International Nuclear Information System (INIS)

    Beauchamp, J.J.; Begovich, C.L.; Kane, V.E.; Wolf, D.A.

    1979-10-01

    The National Uranium Resource Evaluation (NURE) Project has as its goal estimation of the nation's uranium resources. It is possible to use discriminant analysis methods on hydrogeochemical data collected in the NURE Program to aid in formulating geochemical models which can be used to identify the anomalous regions necessary for resource estimation. Discriminant analysis methods have been applied to data from the Plainview, Texas Quadrangle which has approximately 850 groundwater samples with more than 40 quantitative measurements per sample. Discriminant analysis topics involving estimation of misclassification probabilities, variable selection, and robust discrimination are applied. A method using generalized distance measures is given which enables assigning samples to a background population or a mineralized population whose parameters were estimated from separate studies. Each topic is related to its relevance in identifying areas of possible interest to uranium exploration

  2. Long distance elementary measurement of the radiation dose ratio produced by neutron activation

    International Nuclear Information System (INIS)

    Zhou Changgeng; Lou Benchao; Wu Chunlei; Hu Yonghong; Li Yan

    2009-04-01

    The working principle and the structure and performances of a long distance controllable individual radiation dose ratio instrument are described. The radiation dose ratio produced by neutron activation is elementarily measured by using this instrument in the neutron generator hall with high neutron yield. When neutron yield arrives to 2 x 10 11 s -1 , the radiation dose ratio produced by neutron activation is 99.9 μSv/h in 1 h after the generator being stopped. The radiation dose ratio is reduced to 24.4 μSv/h in 39 h after the generator being stopped. When neutron yield is 3.2 x 10 10 s -1 , the radiation dose ratio produced by neutron activation is 21.9 μSv/h in 36 min, after the generator being stopped. The measurement results may provide reference for physical experimenters and neutron generator operators. (authors)

  3. Coherent dual-frequency lidar system design for distance and speed measurements

    Science.gov (United States)

    Zheng, Xingyuan; Zhao, Changming; Zhang, Haiyang; Zheng, Zheng; Yang, Hongzhi

    2018-01-01

    Lidars have a wide range of applications in military detection and civilian remote sensing. Coherent Dual-Frequency Lidar (CDFL) is a new concept of laser radar that is using electrical coherence instead of optical coherence. It uses laser with two coherent frequency components as transmitting wave. The method is based on the use of an optically-carried radio frequency (RF) signal, which is the frequency difference between the two components, which is specially designed for distance and speed measurements. It not only ensures the system has the characteristics of high spatial resolution, high ranging and velocity precision of laser radar, but also can use mature signal processing technology of microwave radar, and it is a research direction that attracts more concern in recent years. A CDFL detection system is constructed and field experiment is carried out. In the system, a narrow linewidth fiber laser with a wavelength of 1064nm is adopted. The dual-frequency laser with frequency difference of 200MHz and 200.6MHz is obtained by acousto-optic frequency shift and recombination. The maximum output power of dual frequency laser is 200mW. The receiver consists of all-fiber balanced InGaAs photo-detector and homemade analog signal processing board. The experimental results show that the distance resolution and velocity resolution of the system are 0.1m and 0.1m/s separately when the working distance is greater than 200m, and the spatial resolution is 0.5mrad.

  4. Research on in-situ measurement technique of three-dimensional distance

    International Nuclear Information System (INIS)

    Shiraishi, Masatake; Aoshima, Shinichi; Aose, Shinichi; Takeuchi, Masayuki

    2004-04-01

    Equipments used in the nuclear facility must be done the adequate maintenance and should be exchanged to new ones by the remote control. For this aim, we need information about the objects such as a distance, a profile, and an inclination with the required accuracy. The aim of this research is, thus, to establish and equipment exchanging method by controlling the position of equipments and parts. In order to catch the whole position condition of objects, a rough measurement system was developed, and information was obtained from the front side of parts. Then, a precise measurement system that performs local measurement was constructed to obtain the information around the shade portion of the objects, which is not obtainable by the rough measurement system. Therefore, the new system performs two measurements: a rough measurement and a precise measurement. Consequently, it was found to be effective for acquiring a lot of information that are not obtained only by the rough measurement system form the front side only. Before exchanging equipments, we need to know their conditions whether they are still applicable or not. The another point of this research is, therefore, to develop an on-line deterioration diagnosis method of equipments. Specifically, a new approach in which the laser light is projected onto the equipment surface is proposed to check the contrast of the reflection pattern. Because the contrast is corresponding to the condition of the measured surface and therefore we can conjecture the surface states of the object surface by obtaining the contrast. We examined those states empirically by changing the laser angle of incidence and the receiving angle of camera. As a result, the validity of the on-line diagnosis was confirmed through various experiments. Finally, the possibility of applying VR method was discussed as a control of robot manipulator, although this research is on going. (author)

  5. The Effect of Changing Focal Trough in a Panoramic Device on the Accuracy of Distance Measurements

    Directory of Open Access Journals (Sweden)

    Mehrdad Abdinian

    2018-01-01

    Full Text Available >Introduction: Magnification and distortion are the most important limitations of panoramic radiography. The aim of this study was to determine the effects of changing focal trough option of Planmeca SCARA 3 on the accuracy of linear distance measurements.Materials and Methods: In this in-vitro study, 28 pieces of gutta-percha were attached to the assumptive place of each lost root of an adult dry skull with average size and normal shape. The actual measurements were obtained by a digital caliper. The panoramic images of the skull were taken in six different sizes and shapes of focal trough. This procedure was repeated ten times with new gutta-percha. Paired t-test was used to compare the values of different actual and radiographic images of gutta-percha dimensions.Results: The mean difference [standard deviation (SD] between actual measurement and panoramic radiography in the different groups was from 0.37 (1.1 to 0.58 (2.87 mm. The mean (SD difference of linear measurements between real and radiographic images was 0.52 (0.43 mm in average size, V-shaped group, which was statistically and clinically significant (P = 0.00.Conclusion: Changing the focal trough option of Planmeca SCARA 3 has minimal effects on the accuracy of linear measurements in panoramic radiographs.

  6. EDUCATEE'S THESAURUS AS AN OBJECT OF MEASURING LEARNED MATERIAL OF THE DISTANCE LEARNING COURSE

    Directory of Open Access Journals (Sweden)

    Alexander Aleksandrovich RYBANOV

    2013-10-01

    Full Text Available Monitoring and control over the process of studying the distance learning course are based on solving the problem of making out an adequate integral mark to the educatee for mastering entire study course, by testing results. It is suggested to use the degree of correspondence between educatee's thesaurus and the study course thesaurus as an integral mark for the degree of mastering the distance learning course. Study course thesaurus is a set of the course objects with relations between them specified. The article considers metrics of the study course thesaurus complexity, made on the basis of the graph theory and the information theory. It is suggested to use the amount of information contained in the study course thesaurus graph as the metrics of the study course thesaurus complexity. Educatee's thesaurus is considered as an object of measuring educational material learned at the semantic level and is assessed on the basis of amount of information contained in its graph, taking into account the factors of learning the thesaurus objects.

  7. Accurate measurements of E2 lifetimes using the coincidence recoil-distance method

    Science.gov (United States)

    Bhalla, R. K.; Poletti, A. R.

    1984-05-01

    Mean lives of four E2 transitions in the (2s, 1d) shell have been measured using the recoil-distance method (RDM), γ-rays de-exciting the level of interest were detected in coincidence with particles detected in an annular detector at a backward angle thereby reducing the background and producing a beam of recoiling nuclei of well-defined energy and recoil direction. Lifetimes measured were: 22Ne, 1.275 MeV level (2 + → 0 +), 5.16±0.13 ps; 26Mg, 3.588 MeV level (0 + → 2 +), 9.29±0.23 ps; 30Si, 3.788 MeV level (0 +→ 2 +), 12.00±0.70 ps; 38Ar, 3.377 MeV level (0 + → 2 +), 34.5±1.5 ps. The present measurements are compared to those of previous investigators. For the 22Ne level, averaged results from four different measurement techniques are compared and found to be in good agreement. The experimental results are compared to shell-model calculations.

  8. Accurate measurements of E2 lifetimes using the coincidence recoil-distance method

    International Nuclear Information System (INIS)

    Bhalla, R.K.; Poletti, A.R.

    1984-01-01

    Mean lives of four E2 transitions in the (2s, 1d) shell have been measured using the recoil-distance method (RDM). γ-rays de-exciting the level of interest were detected in coincidence with particles detected in an annular detector at a backward angle thereby reducing the background and producing a beam of recoiling nuclei of well-defined energy and recoil direction. Lifetimes measured were: 22 Ne, 1.275 MeV level (2 + -> 0 + ), 5.16 +- 0.13 ps; 26 Mg, 3.588 MeV level (0 + -> 2 + ), 9.29 +- 0.23 ps; 30 Si, 3.788 MeV level (0 + -> 2 + ), 12.00 +- 0.70 ps; 38 Ar, 3.377 MeV level (0 + -> 2 + ), 34.5 +- 1.5 ps. The present measurements are compared to those of previous investigators. For the 22 Ne level, averaged results from four different measurement techniques are compared and found to be in good agreement. The experimental results are compared to shell-model calculations. (orig.)

  9. Constraints on cosmic opacity and beyond the standard model physics from cosmological distance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Avgoustidis, Anastasios [Centre for Theoretical Cosmology, DAMTP, CMS, Wilberforce Road, Cambridge CB3 0WA (United Kingdom); Burrage, Clare [Deutsches Elektronen Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg (Germany); Redondo, Javier [Max Planck Institut für Physik, Föhringer Ring 6, D-80805, Munich (Germany); Verde, Licia; Jimenez, Raul, E-mail: a.avgoustidis@damtp.cam.ac.uk, E-mail: clare.burrage@desy.de, E-mail: redondo@mppmu.mpg.de, E-mail: liciaverde@icc.ub.edu, E-mail: raul.jimenez@icc.ub.edu [ICREA and Institute for Sciences of the Cosmos (ICC), University of Barcelona, IEEC, Barcelona 08028 (Spain)

    2010-10-01

    We update constraints on cosmic opacity by combining recent SN Type Ia data with the latest measurements of the Hubble expansion at redshifts between 0 and 2. The new constraint on the parameter ε parametrising deviations from the luminosity-angular diameter distance relation (d{sub L} = d{sub A}(1+z){sup 2+ε}), is ε = −0.04{sub −0.07}{sup +0.08} (2-σ). For the redshift range between 0.2 and 0.35 this corresponds to an opacity Δτ < 0.012 (95% C.L.), a factor of 2 stronger than the previous constraint. Various models of beyond the standard model physics that predict violation of photon number conservation contribute to the opacity and can be equally constrained. In this paper we put new limits on axion-like particles, including chameleons, and mini-charged particles.

  10. Constraints on cosmic opacity and beyond the standard model physics from cosmological distance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Avgoustidis, Anastasios [DAMTP, CMS, Cambridge (United Kingdom). Centre for Theoretical Cosmology; Burrage, Clare [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Redondo, Javier [Max-Planck-Institut fuer Physik, Munich (Germany); Verde, Licia; Jimenez, Raul [Barcelona Univ., IEEC (ES). ICREA and Inst. for Sciences of the Cosmos (ICC)

    2010-04-15

    We update constraints on cosmic opacity by combining recent SN Type Ia data compilation with the latest measurements of the Hubble expansion at redshifts between 0 and 2. The new constraint on the parameter {epsilon} parametrising deviations from the luminosity-angular diameter distance relation (d{sub L}=d{sub A}(1+z){sup 2+{epsilon}}), is {epsilon}=-0.04{sub -0.07}{sup +0.08} (2-{sigma}). For the redshift range between 0.2 and 0.35 this corresponds to an opacity {delta}{tau}<0.012 (95% C.L.), a factor of 2 stronger than the previous constraint. Various models of beyond the standard model physics that predict violation of photon number conservation contribute to the opacity and can be equally constrained. In this paper we put new limits on axion-like particles, including chameleons, and minicharged particles. (orig.)

  11. Slicing, sampling, and distance-dependent effects affect network measures in simulated cortical circuit structures

    Directory of Open Access Journals (Sweden)

    Daniel Carl Miner

    2014-11-01

    Full Text Available The neuroanatomical connectivity of cortical circuits is believed to follow certain rules, the exact origins of which are still poorly understood. In particular, numerous nonrandom features, such as common neighbor clustering, overrepresentation of reciprocal connectivity, and overrepresentation of certain triadic graph motifs have been experimentally observed in cortical slice data. Some of these data, particularly regarding bidirectional connectivity are seemingly contradictory, and the reasons for this are unclear. Here we present a simple static geometric network model with distance-dependent connectivity on a realistic scale that naturally gives rise to certain elements of these observed behaviors, and may provide plausible explanations for some of the conflicting findings. Specifically, investigation of the model shows that experimentally measured nonrandom effects, especially bidirectional connectivity, may depend sensitively on experimental parameters such as slice thickness and sampling area, suggesting potential explanations for the seemingly conflicting experimental results.

  12. Slicing, sampling, and distance-dependent effects affect network measures in simulated cortical circuit structures.

    Science.gov (United States)

    Miner, Daniel C; Triesch, Jochen

    2014-01-01

    The neuroanatomical connectivity of cortical circuits is believed to follow certain rules, the exact origins of which are still poorly understood. In particular, numerous nonrandom features, such as common neighbor clustering, overrepresentation of reciprocal connectivity, and overrepresentation of certain triadic graph motifs have been experimentally observed in cortical slice data. Some of these data, particularly regarding bidirectional connectivity are seemingly contradictory, and the reasons for this are unclear. Here we present a simple static geometric network model with distance-dependent connectivity on a realistic scale that naturally gives rise to certain elements of these observed behaviors, and may provide plausible explanations for some of the conflicting findings. Specifically, investigation of the model shows that experimentally measured nonrandom effects, especially bidirectional connectivity, may depend sensitively on experimental parameters such as slice thickness and sampling area, suggesting potential explanations for the seemingly conflicting experimental results.

  13. Constraints on cosmic opacity and beyond the standard model physics from cosmological distance measurements

    International Nuclear Information System (INIS)

    Avgoustidis, Anastasios; Redondo, Javier; Verde, Licia; Jimenez, Raul

    2010-04-01

    We update constraints on cosmic opacity by combining recent SN Type Ia data compilation with the latest measurements of the Hubble expansion at redshifts between 0 and 2. The new constraint on the parameter ε parametrising deviations from the luminosity-angular diameter distance relation (d L =d A (1+z) 2+ε ), is ε=-0.04 -0.07 +0.08 (2-σ). For the redshift range between 0.2 and 0.35 this corresponds to an opacity Δτ<0.012 (95% C.L.), a factor of 2 stronger than the previous constraint. Various models of beyond the standard model physics that predict violation of photon number conservation contribute to the opacity and can be equally constrained. In this paper we put new limits on axion-like particles, including chameleons, and minicharged particles. (orig.)

  14. Ratbot automatic navigation by electrical reward stimulation based on distance measurement in unknown environments.

    Science.gov (United States)

    Gao, Liqiang; Sun, Chao; Zhang, Chen; Zheng, Nenggan; Chen, Weidong; Zheng, Xiaoxiang

    2013-01-01

    Traditional automatic navigation methods for bio-robots are constrained to configured environments and thus can't be applied to tasks in unknown environments. With no consideration of bio-robot's own innate living ability and treating bio-robots in the same way as mechanical robots, those methods neglect the intelligence behavior of animals. This paper proposes a novel ratbot automatic navigation method in unknown environments using only reward stimulation and distance measurement. By utilizing rat's habit of thigmotaxis and its reward-seeking behavior, this method is able to incorporate rat's intrinsic intelligence of obstacle avoidance and path searching into navigation. Experiment results show that this method works robustly and can successfully navigate the ratbot to a target in the unknown environment. This work might put a solid base for application of ratbots and also has significant implication of automatic navigation for other bio-robots as well.

  15. Spectral interferometry including the effect of transparent thin films to measure distances and displacements

    International Nuclear Information System (INIS)

    Hlubina, P.

    2004-01-01

    A spectral-domain interferometric technique is applied for measuring mirror distances and displacements in a dispersive Michelson interferometer when the effect of transparent thin films coated onto the interferometer beam splitter and compensator is known. We employ a low-resolution spectrometer in two experiments with different amounts of dispersion in a Michelson interferometer that includes fused-silica optical sample. Knowing the thickness of the optical sample and the nonlinear phase function of the thin films, the positions of the interferometer mirror are determined precisely by a least-squares fitting of the theoretical spectral interferograms to the recorded ones. We compare the results of the processing that include and do not include the effect of transparent thin films (Author)

  16. Novel Distance Measure in Fuzzy TOPSIS for Supply Chain Strategy Based Supplier Selection

    Directory of Open Access Journals (Sweden)

    B. Pardha Saradhi

    2016-01-01

    Full Text Available In today’s highly competitive environment, organizations need to evaluate and select suppliers based on their manufacturing strategy. Identification of supply chain strategy of the organization, determination of decision criteria, and methods of supplier selection are appearing to be the most important components in research area in the field of supply chain management. In this paper, evaluation of suppliers is done based on the balanced scorecard framework using new distance measure in fuzzy TOPSIS by considering the supply chain strategy of the manufacturing organization. To take care of vagueness in decision making, trapezoidal fuzzy number is assumed for pairwise comparisons to determine relative weights of perspectives and criteria of supplier selection. Also, linguistic variables specified in terms of trapezoidal fuzzy number are considered for the payoff values of criteria of the suppliers. These fuzzy numbers satisfied the Jensen based inequality. A detailed application of the proposed methodology is illustrated.

  17. A definition of distance and method of making space-time measurements

    International Nuclear Information System (INIS)

    Brisson, D.W.

    1980-01-01

    The paper explores an extended definition of the absolute value of a complex number and thus a new definition of distance. This new definition, called the nabsolute value of a complex number, is (Z) where Z = (a or ia) + (b or ib), so that (Z) is equivalent to [α 2 + β 2 ]sup(1/2), and α = a or ia, β = b or ib. This is shown on a superimposed X,Y plot and iX,iY plot so that four dimensions are represented in a plane. The application of this scheme to space-time measurement is then identified with the Minkowski Plane which has identical properties with the complex plane, with this new interpretation of the absolute value of a complex number. (Auth.)

  18. Comparing two distance measures in the spatial mapping of food deserts: The case of Petržalka, Slovakia

    Directory of Open Access Journals (Sweden)

    Bilková Kristína

    2017-06-01

    Full Text Available Over the last twenty years or so, researchers’ attention to the issue of food deserts has increased in the geographical literature. Accessibility to large-scale retail units is one of the essential and frequently-used indicators leading to the identification and mapping of food deserts. Numerous accessibility measures of various types are available for this purpose. Euclidean distance and street network distance rank among the most frequently-used approaches, although they may lead to slightly different results. The aim of this paper is to compare various approaches to the accessibility to food stores and to assess the differences in the results gained by these methods. Accessibility was measured for residential block centroids, with applications of various accessibility measures in a GIS environment. The results suggest a strong correspondence between Euclidean distance and a little more accurate street network distance approach, applied in the case of the urban environment of Bratislava-Petržalka, Slovakia.

  19. Measurement of the phase difference between short- and long-distance amplitudes in the [Formula: see text] decay.

    Science.gov (United States)

    Aaij, R; Adeva, B; Adinolfi, M; Ajaltouni, Z; Akar, S; Albrecht, J; Alessio, F; Alexander, M; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amerio, S; Amhis, Y; An, L; Anderlini, L; Andreassi, G; Andreotti, M; Andrews, J E; Appleby, R B; Archilli, F; d'Argent, P; Arnau Romeu, J; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Baalouch, M; Babuschkin, I; Bachmann, S; Back, J J; Badalov, A; Baesso, C; Baker, S; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Baszczyk, M; Batozskaya, V; Batsukh, B; Battista, V; Bay, A; Beaucourt, L; Beddow, J; Bedeschi, F; Bediaga, I; Bel, L J; Bellee, V; Belloli, N; Belous, K; Belyaev, I; Ben-Haim, E; Bencivenni, G; Benson, S; Berezhnoy, A; Bernet, R; Bertolin, A; Betancourt, C; Betti, F; Bettler, M-O; van Beuzekom, M; Bezshyiko, Ia; Bifani, S; Billoir, P; Bird, T; Birnkraut, A; Bitadze, A; Bizzeti, A; Blake, T; Blanc, F; Blouw, J; Blusk, S; Bocci, V; Boettcher, T; Bondar, A; Bondar, N; Bonivento, W; Bordyuzhin, I; Borgheresi, A; Borghi, S; Borisyak, M; Borsato, M; Bossu, F; Boubdir, M; Bowcock, T J V; Bowen, E; Bozzi, C; Braun, S; Britsch, M; Britton, T; Brodzicka, J; Buchanan, E; Burr, C; Bursche, A; Buytaert, J; Cadeddu, S; Calabrese, R; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Campora Perez, D H; Capriotti, L; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carniti, P; Carson, L; Carvalho Akiba, K; Casse, G; Cassina, L; Castillo Garcia, L; Cattaneo, M; Cavallero, G; Cenci, R; Chamont, D; Charles, M; Charpentier, Ph; Chatzikonstantinidis, G; Chefdeville, M; Chen, S; Cheung, S-F; Chobanova, V; Chrzaszcz, M; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coco, V; Cogan, J; Cogneras, E; Cogoni, V; Cojocariu, L; Collazuol, G; Collins, P; Comerma-Montells, A; Contu, A; Cook, A; Coombs, G; Coquereau, S; Corti, G; Corvo, M; Costa Sobral, C M; Couturier, B; Cowan, G A; Craik, D C; Crocombe, A; Cruz Torres, M; Cunliffe, S; Currie, R; D'Ambrosio, C; Da Cunha Marinho, F; Dall'Occo, E; Dalseno, J; David, P N Y; Davis, A; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Serio, M; De Simone, P; Dean, C-T; Decamp, D; Deckenhoff, M; Del Buono, L; Demmer, M; Dendek, A; Derkach, D; Deschamps, O; Dettori, F; Dey, B; Di Canto, A; Dijkstra, H; Dordei, F; Dorigo, M; Dosil Suárez, A; Dovbnya, A; Dreimanis, K; Dufour, L; Dujany, G; Dungs, K; Durante, P; Dzhelyadin, R; Dziurda, A; Dzyuba, A; Déléage, N; Easo, S; Ebert, M; Egede, U; Egorychev, V; Eidelman, S; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; Ely, S; Esen, S; Evans, H M; Evans, T; Falabella, A; Farley, N; Farry, S; Fay, R; Fazzini, D; Ferguson, D; Fernandez Prieto, A; Ferrari, F; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fini, R A; Fiore, M; Fiorini, M; Firlej, M; Fitzpatrick, C; Fiutowski, T; Fleuret, F; Fohl, K; Fontana, M; Fontanelli, F; Forshaw, D C; Forty, R; Franco Lima, V; Frank, M; Frei, C; Fu, J; Funk, W; Furfaro, E; Färber, C; Gallas Torreira, A; Galli, D; Gallorini, S; Gambetta, S; Gandelman, M; Gandini, P; Gao, Y; Garcia Martin, L M; García Pardiñas, J; Garra Tico, J; Garrido, L; Garsed, P J; Gascon, D; Gaspar, C; Gavardi, L; Gazzoni, G; Gerick, D; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gianì, S; Gibson, V; Girard, O G; Giubega, L; Gizdov, K; Gligorov, V V; Golubkov, D; Golutvin, A; Gomes, A; Gorelov, I V; Gotti, C; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graverini, E; Graziani, G; Grecu, A; Griffith, P; Grillo, L; Gruberg Cazon, B R; Grünberg, O; Gushchin, E; Guz, Yu; Gys, T; Göbel, C; Hadavizadeh, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hall, S; Hamilton, B; Han, X; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Harrison, J; Hatch, M; He, J; Head, T; Heister, A; Hennessy, K; Henrard, P; Henry, L; van Herwijnen, E; Heß, M; Hicheur, A; Hill, D; Hombach, C; Hopchev, H; Hulsbergen, W; Humair, T; Hushchyn, M; Hutchcroft, D; Idzik, M; Ilten, P; Jacobsson, R; Jaeger, A; Jalocha, J; Jans, E; Jawahery, A; Jiang, F; John, M; Johnson, D; Jones, C R; Joram, C; Jost, B; Jurik, N; Kandybei, S; Karacson, M; Kariuki, J M; Karodia, S; Kecke, M; Kelsey, M; Kenzie, M; Ketel, T; Khairullin, E; Khanji, B; Khurewathanakul, C; Kirn, T; Klaver, S; Klimaszewski, K; Koliiev, S; Kolpin, M; Komarov, I; Koopman, R F; Koppenburg, P; Kosmyntseva, A; Kozachuk, A; Kozeiha, M; Kravchuk, L; Kreplin, K; Kreps, M; Krokovny, P; Kruse, F; Krzemien, W; Kucewicz, W; Kucharczyk, M; Kudryavtsev, V; Kuonen, A K; Kurek, K; Kvaratskheliya, T; Lacarrere, D; Lafferty, G; Lai, A; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Leflat, A; Lefrançois, J; Lefèvre, R; Lemaitre, F; Lemos Cid, E; Leroy, O; Lesiak, T; Leverington, B; Li, T; Li, Y; Likhomanenko, T; Lindner, R; Linn, C; Lionetto, F; Liu, X; Loh, D; Longstaff, I; Lopes, J H; Lucchesi, D; Lucio Martinez, M; Luo, H; Lupato, A; Luppi, E; Lupton, O; Lusiani, A; Lyu, X; Machefert, F; Maciuc, F; Maev, O; Maguire, K; Malde, S; Malinin, A; Maltsev, T; Manca, G; Mancinelli, G; Manning, P; Maratas, J; Marchand, J F; Marconi, U; Marin Benito, C; Marinangeli, M; Marino, P; Marks, J; Martellotti, G; Martin, M; Martinelli, M; Martinez Santos, D; Martinez Vidal, F; Martins Tostes, D; Massacrier, L M; Massafferri, A; Matev, R; Mathad, A; Mathe, Z; Matteuzzi, C; Mauri, A; Maurice, E; Maurin, B; Mazurov, A; McCann, M; McNab, A; McNulty, R; Meadows, B; Meier, F; Meissner, M; Melnychuk, D; Merk, M; Merli, A; Michielin, E; Milanes, D A; Minard, M-N; Mitzel, D S; Mogini, A; Molina Rodriguez, J; Monroy, I A; Monteil, S; Morandin, M; Morawski, P; Mordà, A; Morello, M J; Morgunova, O; Moron, J; Morris, A B; Mountain, R; Muheim, F; Mulder, M; Mussini, M; Müller, D; Müller, J; Müller, K; Müller, V; Naik, P; Nakada, T; Nandakumar, R; Nandi, A; Nasteva, I; Needham, M; Neri, N; Neubert, S; Neufeld, N; Neuner, M; Nguyen, T D; Nguyen-Mau, C; Nieswand, S; Niet, R; Nikitin, N; Nikodem, T; Nogay, A; Novoselov, A; O'Hanlon, D P; Oblakowska-Mucha, A; Obraztsov, V; Ogilvy, S; Oldeman, R; Onderwater, C J G; Otalora Goicochea, J M; Otto, A; Owen, P; Oyanguren, A; Pais, P R; Palano, A; Palombo, F; Palutan, M; Papanestis, A; Pappagallo, M; Pappalardo, L L; Parker, W; Parkes, C; Passaleva, G; Pastore, A; Patel, G D; Patel, M; Patrignani, C; Pearce, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perret, P; Pescatore, L; Petridis, K; Petrolini, A; Petrov, A; Petruzzo, M; Picatoste Olloqui, E; Pietrzyk, B; Pikies, M; Pinci, D; Pistone, A; Piucci, A; Placinta, V; Playfer, S; Plo Casasus, M; Poikela, T; Polci, F; Poluektov, A; Polyakov, I; Polycarpo, E; Pomery, G J; Popov, A; Popov, D; Popovici, B; Poslavskii, S; Potterat, C; Price, E; Price, J D; Prisciandaro, J; Pritchard, A; Prouve, C; Pugatch, V; Puig Navarro, A; Punzi, G; Qian, W; Quagliani, R; Rachwal, B; Rademacker, J H; Rama, M; Ramos Pernas, M; Rangel, M S; Raniuk, I; Ratnikov, F; Raven, G; Redi, F; Reichert, S; Dos Reis, A C; Remon Alepuz, C; Renaudin, V; Ricciardi, S; Richards, S; Rihl, M; Rinnert, K; Rives Molina, V; Robbe, P; Rodrigues, A B; Rodrigues, E; Rodriguez Lopez, J A; Rodriguez Perez, P; Rogozhnikov, A; Roiser, S; Rollings, A; Romanovskiy, V; Romero Vidal, A; Ronayne, J W; Rotondo, M; Rudolph, M S; Ruf, T; Ruiz Valls, P; Saborido Silva, J J; Sadykhov, E; Sagidova, N; Saitta, B; Salustino Guimaraes, V; Sanchez Mayordomo, C; Sanmartin Sedes, B; Santacesaria, R; Santamarina Rios, C; Santimaria, M; Santovetti, E; Sarti, A; Satriano, C; Satta, A; Saunders, D M; Savrina, D; Schael, S; Schellenberg, M; Schiller, M; Schindler, H; Schlupp, M; Schmelling, M; Schmelzer, T; Schmidt, B; Schneider, O; Schopper, A; Schubert, K; Schubiger, M; Schune, M-H; Schwemmer, R; Sciascia, B; Sciubba, A; Semennikov, A; Sergi, A; Serra, N; Serrano, J; Sestini, L; Seyfert, P; Shapkin, M; Shapoval, I; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, V; Siddi, B G; Silva Coutinho, R; Silva de Oliveira, L; Simi, G; Simone, S; Sirendi, M; Skidmore, N; Skwarnicki, T; Smith, E; Smith, I T; Smith, J; Smith, M; Snoek, H; Soares Lavra, L; Sokoloff, M D; Soler, F J P; Souza De Paula, B; Spaan, B; Spradlin, P; Sridharan, S; Stagni, F; Stahl, M; Stahl, S; Stefko, P; Stefkova, S; Steinkamp, O; Stemmle, S; Stenyakin, O; Stevens, H; Stevenson, S; Stoica, S; Stone, S; Storaci, B; Stracka, S; Straticiuc, M; Straumann, U; Sun, L; Sutcliffe, W; Swientek, K; Syropoulos, V; Szczekowski, M; Szumlak, T; T'Jampens, S; Tayduganov, A; Tekampe, T; Tellarini, G; Teubert, F; Thomas, E; van Tilburg, J; Tilley, M J; Tisserand, V; Tobin, M; Tolk, S; Tomassetti, L; Tonelli, D; Topp-Joergensen, S; Toriello, F; Tournefier, E; Tourneur, S; Trabelsi, K; Traill, M; Tran, M T; Tresch, M; Trisovic, A; Tsaregorodtsev, A; Tsopelas, P; Tully, A; Tuning, N; Ukleja, A; Ustyuzhanin, A; Uwer, U; Vacca, C; Vagnoni, V; Valassi, A; Valat, S; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; van Veghel, M; Velthuis, J J; Veltri, M; Veneziano, G; Venkateswaran, A; Vernet, M; Vesterinen, M; Viana Barbosa, J V; Viaud, B; Vieira, D; Vieites Diaz, M; Viemann, H; Vilasis-Cardona, X; Vitti, M; Volkov, V; Vollhardt, A; Voneki, B; Vorobyev, A; Vorobyev, V; Voß, C; de Vries, J A; Vázquez Sierra, C; Waldi, R; Wallace, C; Wallace, R; Walsh, J; Wang, J; Ward, D R; Wark, H M; Watson, N K; Websdale, D; Weiden, A; Whitehead, M; Wicht, J; Wilkinson, G; Wilkinson, M; Williams, M; Williams, M P; Williams, M; Williams, T; Wilson, F F; Wimberley, J; Wishahi, J; Wislicki, W; Witek, M; Wormser, G; Wotton, S A; Wraight, K; Wyllie, K; Xie, Y; Xing, Z; Xu, Z; Yang, Z; Yao, Y; Yin, H; Yu, J; Yuan, X; Yushchenko, O; Zarebski, K A; Zavertyaev, M; Zhang, L; Zhang, Y; Zhang, Y; Zhelezov, A; Zheng, Y; Zhu, X; Zhukov, V; Zucchelli, S

    2017-01-01

    A measurement of the phase difference between the short- and long-distance contributions to the [Formula: see text] decay is performed by analysing the dimuon mass distribution. The analysis is based on pp collision data corresponding to an integrated luminosity of 3[Formula: see text] collected by the LHCb experiment in 2011 and 2012. The long-distance contribution to the [Formula: see text] decay is modelled as a sum of relativistic Breit-Wigner amplitudes representing different vector meson resonances decaying to muon pairs, each with their own magnitude and phase. The measured phases of the [Formula: see text] and [Formula: see text] resonances are such that the interference with the short-distance component in dimuon mass regions far from their pole masses is small. In addition, constraints are placed on the Wilson coefficients, [Formula: see text] and [Formula: see text], and the branching fraction of the short-distance component is measured.

  20. Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly

    Science.gov (United States)

    Merle, Cormic; Wick, Eric; Hayden, Joseph

    2011-01-01

    This system was one of the test methods considered for measuring the radius of curvature of one or more of the 18 segmented mirrors that form the 6.5 m diameter primary mirror (PM) of the James Webb Space Telescope (JWST). The assembled telescope will be tested at cryogenic temperatures in a 17-m diameter by 27-m high vacuum chamber at the Johnson Space Center. This system uses a Leica Absolute Distance Meter (ADM), at a wavelength of 780 nm, combined with beam-steering and beam-shaping optics to make a differential distance measurement between a ring mirror on the reflective null assembly and individual PM segments. The ADM is located inside the same Pressure-Tight Enclosure (PTE) that houses the test interferometer. The PTE maintains the ADM and interferometer at ambient temperature and pressure so that they are not directly exposed to the telescope s harsh cryogenic and vacuum environment. This system takes advantage of the existing achromatic objective and reflective null assembly used by the test interferometer to direct four ADM beamlets to four PM segments through an optical path that is coincident with the interferometer beam. A mask, positioned on a linear slide, contains an array of 1.25 mm diameter circular subapertures that map to each of the 18 PM segments as well as six positions around the ring mirror. A down-collimated 4 mm ADM beam simultaneously covers 4 adjacent PM segment beamlets and one ring mirror beamlet. The radius, or spacing, of all 18 segments can be measured with the addition of two orthogonally-oriented scanning pentaprisms used to steer the ADM beam to any one of six different sub-aperture configurations at the plane of the ring mirror. The interferometer beam, at a wavelength of 687 nm, and the ADM beamlets, at a wavelength of 780 nm, pass through the objective and null so that the rays are normally incident on the parabolic PM surface. After reflecting off the PM, both the ADM and interferometer beams return to their respective

  1. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD)

    Energy Technology Data Exchange (ETDEWEB)

    Nitschke, Ashley [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology, Aurora, CO (United States); Lambert, Jeffery R. [University of Colorado, Department of Biostatistics and Informatics, Colorado School of Public Health, Aurora, CO (United States); Glueck, Deborah H. [University of Colorado, Department of Biostatistics and Informatics, Colorado School of Public Health, Aurora, CO (United States); University of Colorado School of Medicine, University of Colorado Denver, Department of Radiology, Aurora, CO (United States); Jesse, Mary Kristen; Strickland, Colin [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology and Orthopaedics, Aurora, CO (United States); Mei-Dan, Omer [University of Colorado School of Medicine, University of Colorado Denver, Division of Sports Medicine and Hip Preservation, Department of Orthopaedics, Aurora, CO (United States); Petersen, Brian [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology and Orthopaedics, Aurora, CO (United States); Inland Imaging, Division of Musculoskeletal Radiology, Spokane, WA (United States)

    2015-11-15

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p < 0.001) or TAD (p < 0.001). The diagnostic accuracies of p/a ratio and TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain. (orig.)

  2. Interuncal distance measurements in normal controls and patients with dementia. MR imaging study

    International Nuclear Information System (INIS)

    Ishii, Kazunari; Kitagaki, Hajime; Sakamoto, Setsu; Yamaji, Shigeru; Kono, Michio.

    1995-01-01

    To evaluate the utility of measuring interuncal distance (IUD) as a reflection of the limbic system, we compared the IUD of 60 dementia patients with that of 10 normal controls. We also measured the width of the intracranial compartment (W1 and W2) to correct for differences in individual brain size, and calculated the ratio of IUD/W1 and IUD/W2. IUD could not separate patients with dementia from normal controls, but there were significant differences in IUD/W1 and IUD/W2 between patients with dementia and normal controls. IUD, IUD/W1 and IUD/W2 did not correlate with Mini-Mental Examination score or ADAS score in patients with dementia. We conclude that IUD measurement is not helpful in distinguishing patients with mild stage dementia from normal aged people or as a scale for dementia. However, we suggest that IUD/W1 and IUD/W2 can discriminate between cases of mild dementia and normal aged people. (author)

  3. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD)

    International Nuclear Information System (INIS)

    Nitschke, Ashley; Lambert, Jeffery R.; Glueck, Deborah H.; Jesse, Mary Kristen; Strickland, Colin; Mei-Dan, Omer; Petersen, Brian

    2015-01-01

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p < 0.001) or TAD (p < 0.001). The diagnostic accuracies of p/a ratio and TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain. (orig.)

  4. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD).

    Science.gov (United States)

    Nitschke, Ashley; Lambert, Jeffery R; Glueck, Deborah H; Jesse, Mary Kristen; Mei-Dan, Omer; Strickland, Colin; Petersen, Brian

    2015-11-01

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p TAD (p TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain.

  5. Representing distance, consuming distance

    DEFF Research Database (Denmark)

    Larsen, Gunvor Riber

    Title: Representing Distance, Consuming Distance Abstract: Distance is a condition for corporeal and virtual mobilities, for desired and actual travel, but yet it has received relatively little attention as a theoretical entity in its own right. Understandings of and assumptions about distance...... are being consumed in the contemporary society, in the same way as places, media, cultures and status are being consumed (Urry 1995, Featherstone 2007). An exploration of distance and its representations through contemporary consumption theory could expose what role distance plays in forming...

  6. The skin-to-calyx distance measured by renal ct scan and ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Shan, Chen Jen; Mazzucchi, Eduardo; Payão, Fabio; Gomes, Andrea Cavalanti; Baroni, Ronaldo Hueb; Torricelli, Fabio Cesar; Vicentini, Fabio Carvalho; Srougi, Miguel [Hospital das Clínicas, University of Sao Paulo Medical School, Sao Paulo, SP (Brazil)

    2014-03-15

    Purpose: We developed a stereotactic device to guide the puncture for percutaneous nephrolithotripsy, which uses the distance from the target calyx to its perpendicular point on skin (SCD) to calculate the needle´s entry angle. This study seeks to validate the use of measurements obtained by ultrasound (US) and computerized tomography (CT) for needle´s entry angle calculation and to study factors that may interfere in this procedure. Materials and Methods: Height, weight, abdominal circumference, CT of the urinary tract in dorsal decubitus (DD) and ventral decubitus (VD), and US of the kidneys in VD were obtained from thirty-five renal calculi patients. SCD obtained were compared and correlated with body-mass index (BMI). Results: BMI was 28.66 ± 4.6 Kg/m2. SCD on CT in DD was 8.40 ± 2.06cm, in VD was 8.32 ± 1.95cm, in US was 6.74 ± 1.68cm. SCD measured by US and CT were statistically different (p < 0.001), whereas between CT in DD and VD were not. SCD of the lower calyx presented moderate correlation with BMI. Conclusion: SCD obtained by CT in ventral and dorsal decubitus may be used for calculation of the needle´s entry angle. SCD obtained by US cannot be used. A rule for the correlation between BMI and the SCD could not be determined. (author)

  7. On the importance of the distance measures used to train and test knowledge-based potentials for proteins

    DEFF Research Database (Denmark)

    Carlsen, Martin; Koehl, Patrice; Røgen, Peter

    2014-01-01

    (PPD), while the other had the set of all distances filtered to reflect consistency in an ensemble of decoys (PPE). We tested four types of metric to characterize the distance between the decoy and the native structure, two based on extrinsic geometry (RMSD and GTD-TS*), and two based on intrinsic...... geometry (Q* and MT). The corresponding eight potentials were tested on a large collection of decoy sets. We found that it is usually better to train a potential using an intrinsic distance measure. We also found that PPE outperforms PPD, emphasizing the benefits of capturing consistent information...

  8. Recoil Distance Method lifetime measurements via gamma-ray and charged-particle spectroscopy at NSCL

    Science.gov (United States)

    Voss, Philip Jonathan

    The Recoil Distance Method (RDM) is a well-established technique for measuring lifetimes of electromagnetic transitions. Transition matrix elements derived from the lifetimes provide valuable insight into nuclear structure. Recent RDM investigations at NSCL present a powerful new model-independent tool for the spectroscopy of nuclei with extreme proton-to-neutron ratios that exhibit surprising behavior. Neutron-rich 18C is one such example, where a small B(E2; 2+1 → 0+gs) represented a dramatic shift from the expected inverse relationship between the B(E2) and 2+1 excitation energy. To shed light on the nature of this quadrupole excitation, the RDM lifetime technique was applied with the Koln/NSCL plunger. States in 18C were populated by the one-proton knockout reaction of a 19N secondary beam. De-excitation gamma rays were detected with the Segmented Germanium Array in coincidence with reaction residues at the focal plane of the S800 Magnetic Spectrometer. The deduced B(E2) and excitation energy were both well described by ab initio no-core shell model calculations. In addition, a novel extension of RDM lifetime measurements via charged-particle spectroscopy of exotic proton emitters has been investigated. Substituting the reaction residue degrader of the Koln/NSCL plunger with a thin silicon detector permits the study of short-lived nuclei beyond the proton dripline. A proof of concept measurement of the mean lifetime of the two-proton emitter 19Mg was conducted. The results indicated a sub-picosecond lifetime, one order of magnitude smaller than the published results, and validate this new technique for lifetime measurements of charged-particle emitters.

  9. Functional claudication distance: a reliable and valid measurement to assess functional limitation in patients with intermittent claudication

    Directory of Open Access Journals (Sweden)

    Prins Martin H

    2009-03-01

    Full Text Available Abstract Background Disease severity and functional impairment in patients with intermittent claudication is usually quantified by the measurement of pain-free walking distance (intermittent claudication distance, ICD and maximal walking distance (absolute claudication distance, ACD. However, the distance at which a patient would prefer to stop because of claudication pain seems a definition that is more correspondent with the actual daily life walking distance. We conducted a study in which the distance a patient prefers to stop was defined as the functional claudication distance (FCD, and estimated the reliability and validity of this measurement. Methods In this clinical validity study we included patients with intermittent claudication, following a supervised exercise therapy program. The first study part consisted of two standardised treadmill tests. During each test ICD, FCD and ACD were determined. Primary endpoint was the reliability as represented by the calculated intra-class correlation coefficients. In the second study part patients performed a standardised treadmill test and filled out the Rand-36 questionnaire. Spearman's rho was calculated to assess validity. Results The intra-class correlation coefficients of ICD, FCD and ACD were 0.940, 0.959, and 0.975 respectively. FCD correlated significantly with five out of nine domains, namely physical function (rho = 0.571, physical role (rho = 0.532, vitality (rho = 0.416, pain (rho = 0.416 and health change (rho = 0.414. Conclusion FCD is a reliable and valid measurement for determining functional capacity in trained patients with intermittent claudication. Furthermore it seems that FCD better reflects the actual functional impairment. In future studies, FCD could be used alongside ICD and ACD.

  10. Constraints on the CMB temperature-redshift dependence from SZ and distance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Avgoustidis, A. [School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD (United Kingdom); Luzzi, G. [Laboratoire de l' Accélérateur Linéaire, Université de Paris-Sud, CNRS/IN2P3, Bâtiment 200, BP 34, 91898 Orsay Cedex (France); Martins, C.J.A.P.; Monteiro, A.M.R.V.L., E-mail: A.Avgoustidis@damtp.cam.ac.uk, E-mail: gluzzi@lal.in2p3.fr, E-mail: Carlos.Martins@astro.up.pt, E-mail: up090322024@alunos.fc.up.pt [Centro de Astrofísica, Universidade do Porto, Rua das Estrelas, 4150-762 Porto (Portugal)

    2012-02-01

    The relation between redshift and the CMB temperature, T{sub CMB}(z) = T{sub 0}(1+z) is a key prediction of standard cosmology, but is violated in many non-standard models. Constraining possible deviations to this law is an effective way to test the ΛCDM paradigm and search for hints of new physics. We present state-of-the-art constraints, using both direct and indirect measurements. In particular, we point out that in models where photons can be created or destroyed, not only does the temperature-redshift relation change, but so does the distance duality relation, and these departures from the standard behaviour are related, providing us with an opportunity to improve constraints. We show that current datasets limit possible deviations of the form T{sub CMB}(z) = T{sub 0}(1+z){sup 1−β} to be β = 0.004±0.016 up to a redshift z ∼ 3. We also discuss how, with the next generation of space and ground-based experiments, these constraints can be improved by more than one order of magnitude.

  11. Constraints on the CMB temperature-redshift dependence from SZ and distance measurements

    International Nuclear Information System (INIS)

    Avgoustidis, A.; Luzzi, G.; Martins, C.J.A.P.; Monteiro, A.M.R.V.L.

    2012-01-01

    The relation between redshift and the CMB temperature, T CMB (z) = T 0 (1+z) is a key prediction of standard cosmology, but is violated in many non-standard models. Constraining possible deviations to this law is an effective way to test the ΛCDM paradigm and search for hints of new physics. We present state-of-the-art constraints, using both direct and indirect measurements. In particular, we point out that in models where photons can be created or destroyed, not only does the temperature-redshift relation change, but so does the distance duality relation, and these departures from the standard behaviour are related, providing us with an opportunity to improve constraints. We show that current datasets limit possible deviations of the form T CMB (z) = T 0 (1+z) 1−β to be β = 0.004±0.016 up to a redshift z ∼ 3. We also discuss how, with the next generation of space and ground-based experiments, these constraints can be improved by more than one order of magnitude

  12. Direct assessment as a measure of institutional effectiveness in a dental hygiene distance education program.

    Science.gov (United States)

    Olmsted, Jodi L

    2014-10-01

    This ten-year, longitudinal examination of a dental hygiene distance education (DE) program considered student performance on standard benchmark assessments as direct measures of institutional effectiveness. The aim of the study was to determine if students face-to-face in a classroom with an instructor performed differently from their counterparts in a DE program, taking courses through the alternative delivery system of synchronous interactive television (ITV). This study used students' grade point averages and National Board Dental Hygiene Examination scores to assess the impact of ITV on student learning, filling a crucial gap in current evidence. The study's research population consisted of 189 students who graduated from one dental hygiene program between 1997 and 2006. One hundred percent of the institution's data files for these students were used: 117 students were face-to-face with the instructor, and seventy-two received instruction through the ITV system. The results showed that, from a year-by-year perspective, no statistically significant performance differences were apparent between the two student groups when t-tests were used for data analysis. The DE system examined was considered effective for delivering education if similar performance outcomes were the evaluation criteria used for assessment.

  13. Can a clinical placement influence stigma? An analysis of measures of social distance.

    Science.gov (United States)

    Moxham, Lorna; Taylor, Ellie; Patterson, Christopher; Perlman, Dana; Brighton, Renee; Sumskis, Susan; Keough, Emily; Heffernan, Tim

    2016-09-01

    The way people who experience mental illness are perceived by health care professionals, which often includes stigmatising attitudes, can have a significant impact on treatment outcomes and on their quality of life. To determine whether stigma towards people with mental illness varied for undergraduate nursing students who attended a non-traditional clinical placement called Recovery Camp compared to students who attended a 'typical' mental health clinical placement. Quasi-experimental. Seventy-nine third-year nursing students were surveyed; n=40 attended Recovery Camp (intervention), n=39 (comparison group) attended a 'typical' mental health clinical placement. All students completed the Social Distance Scale (SDS) pre- and post-placement and at three-month follow-up. Data analysis consisted of a one-way repeated measures analysis of variance (ANOVA) exploring parameter estimates between group scores across three time points. Two secondary repeated measures ANOVAs were performed to demonstrate the differences in SDS scores for each group across time. Pairwise comparisons demonstrated the differences between time intervals. A statistically significant difference in ratings of stigma between the intervention group and the comparison group existed. Parameter estimates revealed that stigma ratings for the intervention group were significantly reduced post-placement and remained consistently low at three-month follow-up. There was no significant difference in ratings of stigma for the comparison group over time. Students who attended Recovery Camp reported significant decreases in stigma towards people with a mental illness over time, compared to the typical placement group. Findings suggest that a therapeutic recreation based clinical placement was more successful in reducing stigma regarding mental illness in undergraduate nursing students compared to those who attended typical mental health clinical placements. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Attributed graph distance measure for automatic detection of attention deficit hyperactive disordered subjects.

    Science.gov (United States)

    Dey, Soumyabrata; Rao, A Ravishankar; Shah, Mubarak

    2014-01-01

    Attention Deficit Hyperactive Disorder (ADHD) is getting a lot of attention recently for two reasons. First, it is one of the most commonly found childhood disorders and second, the root cause of the problem is still unknown. Functional Magnetic Resonance Imaging (fMRI) data has become a popular tool for the analysis of ADHD, which is the focus of our current research. In this paper we propose a novel framework for the automatic classification of the ADHD subjects using their resting state fMRI (rs-fMRI) data of the brain. We construct brain functional connectivity networks for all the subjects. The nodes of the network are constructed with clusters of highly active voxels and edges between any pair of nodes represent the correlations between their average fMRI time series. The activity level of the voxels are measured based on the average power of their corresponding fMRI time-series. For each node of the networks, a local descriptor comprising of a set of attributes of the node is computed. Next, the Multi-Dimensional Scaling (MDS) technique is used to project all the subjects from the unknown graph-space to a low dimensional space based on their inter-graph distance measures. Finally, the Support Vector Machine (SVM) classifier is used on the low dimensional projected space for automatic classification of the ADHD subjects. Exhaustive experimental validation of the proposed method is performed using the data set released for the ADHD-200 competition. Our method shows promise as we achieve impressive classification accuracies on the training (70.49%) and test data sets (73.55%). Our results reveal that the detection rates are higher when classification is performed separately on the male and female groups of subjects.

  15. Attributed graph distance measure for automatic detection of Attention Deficit Hyperactive Disordered subjects

    Directory of Open Access Journals (Sweden)

    Soumyabrata eDey

    2014-06-01

    Full Text Available Attention Deficit Hyperactive Disorder (ADHD is getting a lot of attention recently for two reasons. First, it is one of the most commonly found childhood disorders and second, the root cause of the problem is still unknown. Functional Magnetic Resonance Imaging (fMRI data has become a popular tool for the analysis of ADHD, which is the focus of our current research. In this paper we propose a novel framework for the automatic classification of the ADHD subjects using their resting state fMRI (rs-fMRI data of the brain. We construct brain functional connectivity networks for all the subjects. The nodes of the network are constructed with clusters of highly active voxels and edges between any pair of nodes represent the correlations between their average fMRI time series. The activity level of the voxels are measured based on the average power of their corresponding fMRI time-series. For each node of the networks, a local descriptor comprising of a set of attributes of the node is computed. Next, the Multi-Dimensional Scaling (MDS technique is used to project all the subjects from the unknown graph-space to a low dimensional space based on their inter-graph distance measures. Finally, the Support Vector Machine (SVM classifier is used on the low dimensional projected space for automatic classification of the ADHD subjects. Exhaustive experimental validation of the proposed method is performed using the data set released for the ADHD-200 competition. Our method shows promise as we achieve impressive classification accuracies on the training (70.49% and test data sets (73.55%. Our results reveal that the detection rates are higher when classification is performed separately on the male and female groups of subjects.

  16. Cultural Distance Revisited: Towards a More Rigorous Conceptualization and Measurement of Cultural Differences

    OpenAIRE

    Oded Shenkar

    2001-01-01

    Cultural distance is a widely used construct in international business, where it has been applied to foreign investment expansion, entry mode choice, and the performance of foreign invested affiliates, among others. The present paper presents a critical review of the cultural distance construct, outlining its hidden assumptions and challenging its theoretical and methodological properties. A comprehensive framework for the treatment of the construct is developed and concrete steps aimed at en...

  17. Displacement, distance, and shape measurements of fast-rotating rough objects by two mutually tilted interference fringe systems.

    Science.gov (United States)

    Günther, Philipp; Kuschmierz, Robert; Pfister, Thorsten; Czarske, Jürgen W

    2013-05-01

    The precise distance measurement of fast-moving rough surfaces is important in several applications such as lathe monitoring. A nonincremental interferometer based on two mutually tilted interference fringe systems has been realized for this task. The distance is coded in the phase difference between the generated interference signals corresponding to the fringe systems. Large tilting angles between the interference fringe systems are necessary for a high sensitivity. However, due to the speckle effect at rough surfaces, different envelopes and phase jumps of the interference signals occur. At large tilting angles, these signals become dissimilar, resulting in a small correlation coefficient and a high measurement uncertainty. Based on a matching of illumination and receiving optics, the correlation coefficient and the phase difference estimation have been improved significantly. For axial displacement measurements of recurring rough surfaces, laterally moving with velocities of 5 m/s, an uncertainty of 110 nm has been attained. For nonrecurring surfaces, a distance measurement uncertainty of 830 nm has been achieved. Incorporating the additionally measured lateral velocity and the rotational speed, the two-dimensional shape of rotating objects results. Since the measurement uncertainty of the displacement, distance, and shape is nearly independent of the lateral surface velocity, this technique is predestined for fast-rotating objects, such as crankshafts, camshafts, vacuum pump shafts, or turning parts of lathes.

  18. Variations in reciprocal distances between the ethmoidal sinus, sphenoidal sinus and posterior orbit. Measurement on CTscans

    Energy Technology Data Exchange (ETDEWEB)

    Hayakawa, Kimiko; Yoshikawa, Hiroshi; Suzuki, Miyako; Yokoi, Hidenori; Hosokawa, Akira; Hagiwara, Akiko; Ichikawa, Ginichirou [Juntendo Univ., Tokyo (Japan). School of Medicine

    2003-05-01

    showed 1) 51.3 mm{+-}5.0 mm 2) 76.6 mm{+-}7.9 mm 3) 23.7 mm{+-}2.2 mm 4) 2.1 mm{+-}0.9 mm 5) 15.7 mm{+-}2.0 mm 6) 8.0 mm{+-}1.2 mm in males, and 1) 48.3 mm{+-}4.7 mm 2) 70.3 mm{+-}7.2 mm 3) 22.1 mm{+-}1.9 mm 4) 1.6 mm{+-}0.7 mm 5) 14.2 mm{+-}1.8 mm 6) 7.9 mm{+-}1.3 mm in females. Age and sex-related differences were seen in each area measured, and distances were shortest in the subjects' teens and twenties. The data collected was found to be useful in parasinus operations to prevent complications. (author)

  19. Variations in reciprocal distances between the ethmoidal sinus, sphenoidal sinus and posterior orbit. Measurement on CTscans

    International Nuclear Information System (INIS)

    Hayakawa, Kimiko; Yoshikawa, Hiroshi; Suzuki, Miyako; Yokoi, Hidenori; Hosokawa, Akira; Hagiwara, Akiko; Ichikawa, Ginichirou

    2003-01-01

    showed 1) 51.3 mm±5.0 mm 2) 76.6 mm±7.9 mm 3) 23.7 mm±2.2 mm 4) 2.1 mm±0.9 mm 5) 15.7 mm±2.0 mm 6) 8.0 mm±1.2 mm in males, and 1) 48.3 mm±4.7 mm 2) 70.3 mm±7.2 mm 3) 22.1 mm±1.9 mm 4) 1.6 mm±0.7 mm 5) 14.2 mm±1.8 mm 6) 7.9 mm±1.3 mm in females. Age and sex-related differences were seen in each area measured, and distances were shortest in the subjects' teens and twenties. The data collected was found to be useful in parasinus operations to prevent complications. (author)

  20. Multiwavelength Raman-fiber-laser-based long-distance remote sensor for simultaneous measurement of strain and temperature.

    Science.gov (United States)

    Han, Young-Geun; Tran, T V A; Kim, Sang-Hyuck; Lee, Sang Bae

    2005-06-01

    We propose a simple and flexible multiwavelength Raman-fiber-laser-based long-distance remote-sensing scheme for simultaneous measurement of strain and temperature by use of fiber Bragg gratings. By combining two uniform fiber Bragg gratings with a tunable chirped fiber grating, we readily achieve simultaneous two-channel sensing probes with a high extinction ratio of more than approximately 50 dB over a 50-km distance. When strain and temperature are applied, lasing wavelength separation and shift occur, respectively, since the two uniform fiber Bragg gratings have identical material composition and different cladding diameters. This allows simultaneous measurement of strain and temperature for long-distance sensing applications of more than 50 km.

  1. The Hetu'u Global Network: Measuring the Distance to the Sun with the Transit of Venus

    Science.gov (United States)

    Rodriguez, David; Faherty, J.

    2013-01-01

    In the spirit of historic astronomical endeavors, we invited school groups across the globe to collaborate in a solar distance measurement using the 2012 transit of Venus. In total, our group (stationed at Easter Island, Chile) recruited 19 school groups spread over 6 continents and 10 countries to participate in our Hetu’u Global Network. Applying the methods of French astronomer Joseph-Nicolas Delisle, we used individual second and third Venus-Sun contact times to calculate the distance to the Sun. Ten of the sites in our network had amiable weather; 8 of which measured second contact and 5 of which measured third contact leading to consistent solar distance measurements of 152+/-30 million km and 163+/-30 million km respectively. The distance to the Sun at the time of the transit was 152.25 million km; therefore, our measurements are also consistent within 1-sigma of the known value. The goal of our international school group network was to inspire the next generation of scientists using the excitement and accessibility of such a rare astronomical event. In the process, we connected hundreds of participating students representing a diverse, multi-cultural group with differing political, economic, and racial backgrounds.

  2. A pneumatic bellows-driven setup for controlled-distance electrochemical impedance measurements of Zircaloy-2 in simulated BWR conditions

    International Nuclear Information System (INIS)

    Arilahti, E.; Bojinov, M.; Hansson-Lyyra, L.

    2004-01-01

    This paper describes a novel pneumatic bellows-driven arrangement designed for controlled distance electrochemistry (CDE) measurements. The feasibility of the new arrangement has been verified by performing contact electric impedance measurements to study corrosion of Zircaloy-2 in a re-circulation loop simulating the BWR conditions. Until now, the measurements have been carried out using a step-motor driven controlled-distance electrochemistry (CDE) arrangement. The electrical and electrochemical properties of the pre transition oxide on Zircaloy-2 determined from these measurements were in good agreement with those estimated from measurements with a step-motor driven CDE. Furthermore, the results indicate that the bellows-driven CDE device is less sensitive to the contact pressure variation than the step-motor driven arrangement. This property combined with the bellows driven displacement mechanism provides a clear advantage for future in-core corrosion studies of fuel cladding materials. (Author)

  3. Measuring Oral Proficiency in Distance, Face-to-Face, and Blended Classrooms

    Directory of Open Access Journals (Sweden)

    Robert Blake

    2008-10-01

    Full Text Available Although the foreign-language profession routinely stresses the importance of technology for the curriculum, many teachers still harbor deep-seated doubts as to whether or not a hybrid course, much less a completely distance-learning class, could provide L2 learners with a way to reach linguistic proficiency, especially with respect to oral language skills. In this study, we examine the case of Spanish Without Walls (SWW, a first-year language course offered at the University of California - Davis in both hybrid and distance-learning formats. The SWW curriculum includes materials delivered via CD-ROM/DVD programs, online content-based web pages, and synchronous bimodal chat that includes sound and text. The contribution of each of these components is evaluated in the context of a successful technologically assisted course. To address the issue of oral proficiency, we compare the results from both classroom and distance-learning students who took the 20-minute Versant for Spanish test, delivered by phone and automatically graded. The data generated by this instrument shows that classroom, hybrid, and distance L2 learners reach comparable levels of oral proficiency during their first year of study. Reference is also made to two other ongoing efforts to provide distance-learning courses in Arabic and Punjabi, two languages where special difficulties in their writing systems have an impact on the design of the distant-learning format. The rationale for offering language courses in either a hybrid or distance-learning format is examined in light of increasing societal pressures to help L2 learners reach advanced proficiency, especially in less commonly taught languages (LCTLs.

  4. DL-sQUAL: A Multiple-Item Scale for Measuring Service Quality of Online Distance Learning Programs

    Science.gov (United States)

    Shaik, Naj; Lowe, Sue; Pinegar, Kem

    2006-01-01

    Education is a service with multiplicity of student interactions over time and across multiple touch points. Quality teaching needs to be supplemented by consistent quality supporting services for programs to succeed under the competitive distance learning landscape. ServQual and e-SQ scales have been proposed for measuring quality of traditional…

  5. Functional connectivity and structural covariance between regions of interest can be measured more accurately using multivariate distance correlation.

    Science.gov (United States)

    Geerligs, Linda; Cam-Can; Henson, Richard N

    2016-07-15

    Studies of brain-wide functional connectivity or structural covariance typically use measures like the Pearson correlation coefficient, applied to data that have been averaged across voxels within regions of interest (ROIs). However, averaging across voxels may result in biased connectivity estimates when there is inhomogeneity within those ROIs, e.g., sub-regions that exhibit different patterns of functional connectivity or structural covariance. Here, we propose a new measure based on "distance correlation"; a test of multivariate dependence of high dimensional vectors, which allows for both linear and non-linear dependencies. We used simulations to show how distance correlation out-performs Pearson correlation in the face of inhomogeneous ROIs. To evaluate this new measure on real data, we use resting-state fMRI scans and T1 structural scans from 2 sessions on each of 214 participants from the Cambridge Centre for Ageing & Neuroscience (Cam-CAN) project. Pearson correlation and distance correlation showed similar average connectivity patterns, for both functional connectivity and structural covariance. Nevertheless, distance correlation was shown to be 1) more reliable across sessions, 2) more similar across participants, and 3) more robust to different sets of ROIs. Moreover, we found that the similarity between functional connectivity and structural covariance estimates was higher for distance correlation compared to Pearson correlation. We also explored the relative effects of different preprocessing options and motion artefacts on functional connectivity. Because distance correlation is easy to implement and fast to compute, it is a promising alternative to Pearson correlations for investigating ROI-based brain-wide connectivity patterns, for functional as well as structural data. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Measure synchronization in a spin-orbit-coupled bosonic Josephson junction

    Science.gov (United States)

    Wang, Wen-Yuan; Liu, Jie; Fu, Li-Bin

    2015-11-01

    We present measure synchronization (MS) in a bosonic Josephson junction with spin-orbit coupling. The two atomic hyperfine states are coupled by a Raman dressing scheme, and they are regarded as two orientations of a pseudo-spin-1 /2 system. A feature specific to a spin-orbit-coupled (SOC) bosonic Josephson junction is that the transition from non-MS to MS dynamics can be modulated by Raman laser intensity, even in the absence of interspin atomic interaction. A phase diagram of non-MS and MS dynamics as functions of Raman laser intensity and Josephson tunneling amplitude is presented. Taking into account interspin atomic interactions, the system exhibits MS breaking dynamics resulting from the competition between intraspin and interspin atomic interactions. When interspin atomic interactions dominate in the competition, the system always exhibits MS dynamics. For interspin interaction weaker than intraspin interaction, a window for non-MS dynamics is present. Since SOC Bose-Einstein condensates provide a powerful platform for studies on physical problems in various fields, the study of MS dynamics is valuable in researching the collective coherent dynamical behavior in a spin-orbit-coupled bosonic Josephson junction.

  7. Improve forest inventory with access data-measure transport distance and cost to market.

    Science.gov (United States)

    Dennis P. Bradley

    1972-01-01

    Describes a method for relating forest inventory volumes to transport distances and costs. The process, originally developed in Sweden, includes a computer program that can be used to summarize volumes by transport costs per cord to specified delivery point. The method has many potential applications in all aspects of resource analysis.

  8. Comparing alternative approaches to measuring the geographical accessibility of urban health services: Distance types and aggregation-error issues

    OpenAIRE

    Riva Mylène; Abdelmajid Mohamed; Apparicio Philippe; Shearmur Richard

    2008-01-01

    Abstract Background Over the past two decades, geographical accessibility of urban resources for population living in residential areas has received an increased focus in urban health studies. Operationalising and computing geographical accessibility measures depend on a set of four parameters, namely definition of residential areas, a method of aggregation, a measure of accessibility, and a type of distance. Yet, the choice of these parameters may potentially generate different results leadi...

  9. Alfalfa discovery of the nearby gas-rich dwarf galaxy Leo P. IV. Distance measurement from LBT optical imaging

    Energy Technology Data Exchange (ETDEWEB)

    McQuinn, Kristen B. W.; Skillman, Evan D.; Berg, Danielle [Minnesota Institute for Astrophysics, School of Physics and Astronomy, 116 Church Street, S.E., University of Minnesota, Minneapolis, MN 55455 (United States); Cannon, John M. [Department of Physics and Astronomy, Macalester College, 1600 Grand Avenue, Saint Paul, MN 55105 (United States); Salzer, John J.; Rhode, Katherine L. [Department of Astronomy, Indiana University, 727 East 3rd Street, Bloomington, IN 47405 (United States); Adams, Elizabeth A. K.; Giovanelli, Riccardo; Haynes, Martha P. [Center for Radiophysics and Space Research, Space Sciences Building, Cornell University, Ithaca, NY 14853 (United States); Dolphin, Andrew, E-mail: kmcquinn@astro.umn.edu, E-mail: skillman@astro.umn.edu, E-mail: berg@astro.umn.edu, E-mail: jcannon@macalester.edu, E-mail: rhode@astro.indiana.edu, E-mail: slaz@astro.indiana.edu, E-mail: betsey@astro.cornell.edu, E-mail: riccardo@astro.cornell.edu, E-mail: haynes@astro.cornell.edu [Raytheon Company, 1151 E. Hermans Road, Tucson, AZ 85756 (United States)

    2013-12-01

    Leo P is a low-luminosity dwarf galaxy discovered through the blind H I Arecibo Legacy Fast ALFA survey. The H I and follow-up optical observations have shown that Leo P is a gas-rich dwarf galaxy with both active star formation and an underlying older population, as well as an extremely low oxygen abundance. Here, we measure the distance to Leo P by applying the tip of the red giant branch (TRGB) distance method to photometry of the resolved stellar population from new Large Binocular Telescope V and I band imaging. We measure a distance modulus of 26.19{sub −0.50}{sup +0.17} mag corresponding to a distance of 1.72{sub −0.40}{sup +0.14} Mpc. Although our photometry reaches 3 mag below the TRGB, the sparseness of the red giant branch yields higher uncertainties on the lower limit of the distance. Leo P is outside the Local Group with a distance and velocity consistent with the local Hubble flow. While located in a very low-density environment, Leo P lies within ∼0.5 Mpc of a loose association of dwarf galaxies which include NGC 3109, Antlia, Sextans A, and Sextans B, and 1.1 Mpc away from its next nearest neighbor, Leo A. Leo P is one of the lowest metallicity star-forming galaxies known in the nearby universe, comparable in metallicity to I Zw 18 and DDO 68, but with stellar characteristics similar to dwarf spheriodals (dSphs) in the Local Volume such as Carina, Sextans, and Leo II. Given its physical properties and isolation, Leo P may provide an evolutionary link between gas-rich dwarf irregular galaxies and dSphs that have fallen into a Local Group environment and been stripped of their gas.

  10. Agreement between intraoperative measurements and optical coherence tomography of the limbus-insertion distance of the extraocular muscles.

    Science.gov (United States)

    de-Pablo-Gómez-de-Liaño, L; Fernández-Vigo, J I; Ventura-Abreu, N; Morales-Fernández, L; García-Feijóo, J; Gómez-de-Liaño, R

    2016-12-01

    To assess the agreement between intraoperative measurements of the limbus-insertion distance of the extraocular muscles with those measured by spectral domain optical coherence tomography. An analysis was made of a total of 67 muscles of 21 patients with strabismus. The limbus-insertion distance of the horizontal rectus muscles were measured using pre-operative SD-OCT and intra-operatively in 2 ways: 1) direct, after a conjunctival dissection in patients who underwent surgery, or 2) transconjunctival in patients who were treated with botulinum toxin, or in those who were not going to be operated. The intraclass correlation coefficient and Bland-Altman plots were calculated to determine the concordance between the 2 methods. The mean age was 45.9 ±20.9 years (range 16 to 85), with 52% being women. The percentage of identification by direct intraoperative measurement was 95.6% (22/23), by transconjunctival intraoperative measurement 90.9% (40/44), and by OCT 85% (57/67), with 22 muscles finally being analysed for the agreement study between direct intraoperative measurement and OCT measurements, and 35 muscles for the agreement between transconjuctival intraoperative measurement and OCT. The intraclass correlation coefficient showed good agreement with OCT and direct intraoperative measurements (0.931; 95% confidence interval (95% CI): 0.839-0.972; P<.001), and with transconjunctival intraoperative measurements (0.889; 95% CI: 0.790-0.942; P<.001). The SD-OCT is an effective technique to measure the distance from the insertion of the horizontal rectus muscles to the limbus, with a high agreement with intraoperative measurements being demonstrated. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Fast and accurate measurement of on-axis gain and on-axis polarization at a finite distance

    DEFF Research Database (Denmark)

    Pivnenko, S.; Breinbjerg, O.

    2013-01-01

    -field substitution technique in which the measurement distance is defined between the phase centres of the antennas. The location of the phase centre of the antenna under test (AUT) is found from a quick pattern measurement consisting of only four cuts including the main and diagonal planes. Additionally, in order...... to reduce the amount of measurement data and thus measurement time, the phase centre location is found on a sparse frequency grid and the values in the intermediate points are found by interpolation. The antenna polarization is determined from the amplitude/phase frequency sweeps with two orthogonal AUT...

  12. Absolute distance measurement by dual-comb interferometry with multi-channel digital lock-in phase detection

    International Nuclear Information System (INIS)

    Yang, Ruitao; Pollinger, Florian; Meiners-Hagen, Karl; Krystek, Michael; Bosse, Harald; Tan, Jiubin

    2015-01-01

    We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10 −7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications. (paper)

  13. Absolute distance measurement by dual-comb interferometry with multi-channel digital lock-in phase detection

    Science.gov (United States)

    Yang, Ruitao; Pollinger, Florian; Meiners-Hagen, Karl; Krystek, Michael; Tan, Jiubin; Bosse, Harald

    2015-08-01

    We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10-7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications.

  14. Heterodyne laser Doppler distance sensor with phase coding measuring stationary as well as laterally and axially moving objects

    International Nuclear Information System (INIS)

    Pfister, T; Günther, P; Nöthen, M; Czarske, J

    2010-01-01

    Both in production engineering and process control, multidirectional displacements, deformations and vibrations of moving or rotating components have to be measured dynamically, contactlessly and with high precision. Optical sensors would be predestined for this task, but their measurement rate is often fundamentally limited. Furthermore, almost all conventional sensors measure only one measurand, i.e. either out-of-plane or in-plane distance or velocity. To solve this problem, we present a novel phase coded heterodyne laser Doppler distance sensor (PH-LDDS), which is able to determine out-of-plane (axial) position and in-plane (lateral) velocity of rough solid-state objects simultaneously and independently with a single sensor. Due to the applied heterodyne technique, stationary or purely axially moving objects can also be measured. In addition, it is shown theoretically as well as experimentally that this sensor offers concurrently high temporal resolution and high position resolution since its position uncertainty is in principle independent of the lateral object velocity in contrast to conventional distance sensors. This is a unique feature of the PH-LDDS enabling precise and dynamic position and shape measurements also of fast moving objects. With an optimized sensor setup, an average position resolution of 240 nm was obtained

  15. Distance measurement using frequency-modulated continuous-wave ladar with calibration by a femtosecond frequency comb

    Science.gov (United States)

    Liu, Yang; Yang, Linghui; Lin, Jiarui; Zhu, Jigui

    2018-01-01

    Precise distance measurement is of interest for large-scale manufacturing, future space satellite missions, and other industrial applications. The ranging system with femtosecond optical frequency comb (FOFC) could offer high accuracy, stability and direct traceability to SI definition of the meter. Here, we propose a scheme for length measurement based on the frequency-modulated continuous-wave (FMCW) ladar with a FOFC. In this scheme, the reference interferometer in the FMCW ladar is calibrated by the intensity detection using the FOFC in the time domain within an optical wavelength resolution. With analysis of the theoretical model, this system has the potential to a high-speed, high-accuracy absolute distance measurement. Then, based on the experimental results, the evaluation of the performance of the calibration of the reference arm is discussed. In addition, the performance of this system is evaluated by a single position measurement with different tuning velocities of wavelength. The experimental results show that the reproducibility of the distance measurement is 10-5 level.

  16. A study of the normal interpedicular distance of the spine in Korean teenagers (Estimation of normal range by roentgenographic measurement)

    International Nuclear Information System (INIS)

    Lee, Myung Uk

    1979-01-01

    The radiological measurement of the interpedicular disease using a routine antero-posterior view of the spine gives important clinical criteria in evaluation of the intraspinal tumor and stenosis of the spinal canal, and aids for diagnosis of the lesions. In 1934 Elsberg and Dyke reported values of interpedicular distance as determined on roentgenograms for spine of white adult, and in 1968 Song prepared normal values of interpedicular distance for Korean adult. The present investigation was undertaken to provide normal interpedicular distance of Korean teenagers. The author observed the antero-posterior films of the spine of 200 normal teenagers which were composed of 100 male and 100 female. The normal values of the interpedicular distance of Korean teenagers were obtained, as well as 90% tolerance range for clinical use. In this statistical analysis, there were noted significant differences between male and female, and each age groups. It was observed that average male measurement were consistently larger than female by about 1 mm and the growth of the spinal canal appeared to be continued.

  17. Anogenital distance and penile width measurements in The Infant Development and the Environment Study (TIDES): methods and predictors.

    Science.gov (United States)

    Sathyanarayana, Sheela; Grady, Richard; Redmon, J B; Ivicek, Kristy; Barrett, Emily; Janssen, Sarah; Nguyen, Ruby; Swan, Shanna H

    2015-04-01

    Anogenital distance (AGD) is an androgen responsive anatomic measurement that may have significant utility in clinical and epidemiological research studies. We describe development of standardized measurement methods and predictors of AGD outcomes. We examined infants born to 758 participants in The Infant Development and the Environment Study (TIDES cohort) in four clinical centers in 2011-2013. We developed and implemented a detailed training protocol that incorporated multiple quality control (QC) measures. In males, we measured anoscrotal distance (AGDAS), anopenile distance (AGDAP), and penile width (PW) and in females, anofourchette distance (AGDAF,) and anoclitoral distance (AGDAC). A single examiner obtained three repetitions of all measurements, and a second examiner obtained independent measurements for 14% of infants. We used the intra-rater ICC to assess within-examiner variability and the inter-rater ICC to assess between-examiner variability. We used multivariable linear regression to examine predictors of AGD outcomes including: gestational age at birth, birth weight, gestational age, several measures of body size, race, maternal age, and study center. In the full TIDES cohort, including 758 mothers and children, significant predictors of AGD and PW included: age at exam, gestational age at birth, weight-for-length Z-score, maternal age and study center. In 371 males, the mean (SD) AGDAS, AGDAP, and PW were 24.7 (4.5), 49.6 (5.9), and 10.8 (1.3) mm, respectively. In 387 females, the mean (SD) AGDAF and AGDAC were 16.0 (3.2) mm and 36.7 (3.8) mm, respectively. The intra-examiner ICC and inter-examiner ICC averaged over all subjects and examiners were between 0.89-0.92 and 0.69-0.84 respectively. Our study confirms that with appropriate training and quality control measures, AGD and PW measurements can be performed reliably and accurately in male and female infants. In order for reliable interpretation, these measurements should be adjusted for

  18. On the importance of the distance measures used to train and test knowledge-based potentials for proteins.

    Directory of Open Access Journals (Sweden)

    Martin Carlsen

    Full Text Available Knowledge-based potentials are energy functions derived from the analysis of databases of protein structures and sequences. They can be divided into two classes. Potentials from the first class are based on a direct conversion of the distributions of some geometric properties observed in native protein structures into energy values, while potentials from the second class are trained to mimic quantitatively the geometric differences between incorrectly folded models and native structures. In this paper, we focus on the relationship between energy and geometry when training the second class of knowledge-based potentials. We assume that the difference in energy between a decoy structure and the corresponding native structure is linearly related to the distance between the two structures. We trained two distance-based knowledge-based potentials accordingly, one based on all inter-residue distances (PPD, while the other had the set of all distances filtered to reflect consistency in an ensemble of decoys (PPE. We tested four types of metric to characterize the distance between the decoy and the native structure, two based on extrinsic geometry (RMSD and GTD-TS*, and two based on intrinsic geometry (Q* and MT. The corresponding eight potentials were tested on a large collection of decoy sets. We found that it is usually better to train a potential using an intrinsic distance measure. We also found that PPE outperforms PPD, emphasizing the benefits of capturing consistent information in an ensemble. The relevance of these results for the design of knowledge-based potentials is discussed.

  19. Measuring distance “as the horse runs”: Cross-scale comparison of terrain-based metrics

    Science.gov (United States)

    Buttenfield, Barbara P.; Ghandehari, M; Leyk, S; Stanislawski, Larry V.; Brantley, M E; Qiang, Yi

    2016-01-01

    Distance metrics play significant roles in spatial modeling tasks, such as flood inundation (Tucker and Hancock 2010), stream extraction (Stanislawski et al. 2015), power line routing (Kiessling et al. 2003) and analysis of surface pollutants such as nitrogen (Harms et al. 2009). Avalanche risk is based on slope, aspect, and curvature, all directly computed from distance metrics (Gutiérrez 2012). Distance metrics anchor variogram analysis, kernel estimation, and spatial interpolation (Cressie 1993). Several approaches are employed to measure distance. Planar metrics measure straight line distance between two points (“as the crow flies”) and are simple and intuitive, but suffer from uncertainties. Planar metrics assume that Digital Elevation Model (DEM) pixels are rigid and flat, as tiny facets of ceramic tile approximating a continuous terrain surface. In truth, terrain can bend, twist and undulate within each pixel.Work with Light Detection and Ranging (lidar) data or High Resolution Topography to achieve precise measurements present challenges, as filtering can eliminate or distort significant features (Passalacqua et al. 2015). The current availability of lidar data is far from comprehensive in developed nations, and non-existent in many rural and undeveloped regions. Notwithstanding computational advances, distance estimation on DEMs has never been systematically assessed, due to assumptions that improvements are so small that surface adjustment is unwarranted. For individual pixels inaccuracies may be small, but additive effects can propagate dramatically, especially in regional models (e.g., disaster evacuation) or global models (e.g., sea level rise) where pixels span dozens to hundreds of kilometers (Usery et al 2003). Such models are increasingly common, lending compelling reasons to understand shortcomings in the use of planar distance metrics. Researchers have studied curvature-based terrain modeling. Jenny et al. (2011) use curvature to generate

  20. Quality Assurance of Distance Education: Multiple Assessment Measures Used in a Business, Career, and Technical Education Department

    Directory of Open Access Journals (Sweden)

    Dr. Elizabeth HODGE

    2004-04-01

    Full Text Available Quality Assurance of Distance Education: Multiple Assessment Measures Used in a Business, Career, and Technical Education Department Assistant Professor Dr. Shelia TUCKER East Carolina University, Greenville, NC, USA Assistant Professor Dr. Elizabeth HODGE East Carolina University, Greenville, NC, USA ABSTRACT Educational institutions are being encouraged by accrediting agencies to move beyond the traditional measures of success such as satisfaction surveys from students, employers, and alumni. They stress the use of a variety of measurement tools to audit students’ work. Thus, this study will seek to identify multiple assessment strategies that can be used to evaluate the effectiveness of distance education courses within an entire degree program. Comparisons of three courses being taught simultaneously on line and in the classroom were made. There were no significant differences noted in student outcomes assessments. Additionally, the same assessment measures used for SACS for the traditional classroom were equated with the distance education classes for those in the field of Family and Consumer Sciences, Business Education, the BE/ME program, the MAEd program in Technical teaching, and Information Technologies. No significant differences were noted in student outcomes assessments.

  1. Distance Between the Malleoli and the GroundA New Clinical Method to Measure Leg-Length Discrepancy.

    Science.gov (United States)

    Aguilar, Estela Gomez; Domínguez, Águeda Gómez; Peña-Algaba, Carolina; Castillo-López, José M

    2017-03-01

    The aim of this work is to introduce a useful method for the clinical diagnosis of leg-length inequality: distance between the malleoli and the ground (DMG). A transversal observational study was performed on 17 patients with leg-length discrepancy. Leg-length inequality was determined with different clinical methods: with a tape measure in a supine position from the anterior superior iliac spine (ASIS) to the internal and external malleoli, as the difference between the iliac crests when standing (pelvimeter), and as asymmetry between ASISs (PALpation Meter [PALM]; A&D Medical Products Healthcare, San Jose, California). The Foot Posture Index (FPI) and the navicular drop test were also used. The DMG with Perthes rule (perpendicular to the foot when standing), the distance between the internal malleolus and the ground (DIMG), and the distance between the external malleolus and the ground were designed by the authors. The DIMG is directly related to the traditional ASIS-external malleolus measurement (P = .003), the FPI (P = .010), and the navicular drop test (P DMG) is useful for diagnosing leg-length discrepancy and is related to the ASIS-external malleolus measurement. The DIMG is significantly inversely proportional to the degree of pronation according to the FPI. Conversely, determination of leg-length discrepancy with a tape measure from the ASIS to the malleoli cannot be performed interchangeably at the level of the internal or external malleolus.

  2. Aspects Regarding the Establishment of the Scale Coefficient in the Case of Distances Measurements in an Geodetic Network

    Directory of Open Access Journals (Sweden)

    Mircea Ortelecan

    2016-11-01

    Full Text Available The paper analyzes the possibility to establish the coefficient of scale towards the total station scale triangulation network in the conduct of geodetic and topographic observations in the points with known coordinates (old points or points whose coordinates we want to determine (new points. The purpose of the study is undertaken to simplify computing operations to reduce distances measured from the topographic surface to the Stereo 70 projection plan.

  3. Measurement of distance parameter using semiclassical model in various heavy ion interactions

    Energy Technology Data Exchange (ETDEWEB)

    Nasir, Tabassum [Department of Physics, Gomal University D.I. Khan (Pakistan); Khan, E U [Department of Physics, CIIT, Islamabad (Pakistan); Baluch, J J [Department of Environmental Sciences, CIIT, Abbottabad (Pakistan); Qureshi, I E [Pakistan Atomic Energy Commission, P.O. Box 1114, Islamabad (Pakistan); Sajid, M; Shahzad, M I; Khan, H A [Physics Research Division, PINSTECH, P.O. Nilore, Islamabad (Pakistan)

    2008-08-15

    The technique of solid state nuclear track detection was employed to collect data of elastic scattering as well as inelastic reaction channel. The elastic data of the reactions {sup 238}U+{sup 209}Bi, {sup 238}U+{sup 197}Au, {sup 208}Pb+{sup 197}Au and {sup 197}Au+{sup 197}Au were used to calculate the experimental elastic scattering cross-sections for various angular bins. The ratio of these cross-sections to Rutherford/Mott cross-sections were plotted with respect to distance d({theta}). Distance parameter d{sub 0} in all four reactions was obtained from the discontinuity of the slope following the method suggested in the semiclassical model. Partial reaction cross-sections were also obtained from the inelastic binary as well as multiprong events in the heavy ion interactions of {sup 208}Pb+{sup 197}Au and {sup 197}Au+{sup 197}Au both at 11.67 MeV/u beam energy. The higher values of partial cross-sections of two prong inelastic events as compared with {sigma}{sub 3} and {sigma}{sub 4} have been attributed to the emission of intermediate mass fragments in both the reactions.

  4. A distance measurement between specific sites on the cytoplasmic surface of bovine rhodopsin in rod outer segment disk membranes.

    Science.gov (United States)

    Albert, A D; Watts, A; Spooner, P; Groebner, G; Young, J; Yeagle, P L

    1997-08-14

    Structural information on mammalian integral membrane proteins is scarce. As part of work on an alternative approach to the structure of bovine rhodopsin, a method was devised to obtain an intramolecular distance between two specific sites on rhodopsin while in the rod outer segment disk membrane. In this report, the distance between the rhodopsin kinase phosphorylation site(s) on the carboxyl terminal and the top of the third transmembrane helix was measured on native rhodopsin. Rhodopsin was labeled with a nuclear spin label (31P) by limited phosphorylation with rhodopsin kinase. Major phosphorylation occurs at serines 343 and 338 on the carboxyl terminal. The phosphorylated rhodopsin was then specifically labeled on cysteine 140 with an electron spin label. Magic angle spinning 31P-nuclear magnetic resonance revealed the resonance arising from the phosphorylated protein. The enhancement of the transverse relaxation of this resonance by the paramagnetic spin label was observed. The strength of this perturbation was used to determine the through-space distance between the phosphorylation site(s) and the spin label position. A distance of 18 +/- 3 A was obtained.

  5. Repeated stimulation, inter-stimulus interval and inter-electrode distance alters muscle contractile properties as measured by Tensiomyography

    Science.gov (United States)

    Johnson, Mark I.; Francis, Peter

    2018-01-01

    Context The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG) has not been published. Objective To investigate the; (1) reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm), (2) effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude) and contraction time (Tc), (3) the effect of changing inter-electrode distance on Dm and Tc. Design Within subject, repeated measures. Participants 10 participants for each objective. Main outcome measures Dm and Tc of the rectus femoris, measured using TMG. Results The coefficient of variance (CV) and the intra-class correlation (ICC) of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively. Conclusion Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles. PMID:29451885

  6. SUSTAINABILITY INDICES AS MEASURES OF SERVICE DELIVERY IN OPEN AND DISTANCE LEARNING INSTITUTIONS IN NIGERIA

    Directory of Open Access Journals (Sweden)

    Salawu, I. O, Adeoye, Felix A & Olugbenga David OJO

    2010-01-01

    Full Text Available Open and Distance Education if well organized, is an adequate alternative to conventional education. For acceptability of this assertion, the public, governments, employers of labour and other stakeholders need to be convinced that ODL institutions are not providing half-baked education. Also, for the public and other shareholders enthusiasm and interest that are usually hard earned to be sustained, there is need for total commitment to the implementation of some established indices of sustainability. The thrust of this paper is in the appraisal of the extent to which two ODL institutions in Nigeria adhere to the principles of sustainability. A set of questionnaire was developed and used to collect data which were analyzed using simple non-parametric statistics. Suggestions which were aimed at improving the service delivery, in the institutions used for the study in particular, and other sister institutions especially in the developed countries were highlighted.

  7. Measuring the CO2 shadow price for wastewater treatment: A directional distance function approach

    International Nuclear Information System (INIS)

    Molinos-Senante, María; Hanley, Nick; Sala-Garrido, Ramón

    2015-01-01

    Highlights: • The shadow price of CO 2 informs about the marginal abatement cost of this pollutant. • It is estimated the shadow price of CO 2 for wastewater treatment plants. • The shadow prices depend on the setting of the directional vectors of the distance function. • Sewage sludge treatment technology affects the CO 2 shadow price. - Abstract: The estimation of the value of carbon emissions has become a major research and policy topic since the establishment of the Kyoto Protocol. The shadow price of CO 2 provides information about the marginal abatement cost of this pollutant. It is an essential element in guiding environmental policy issues, since the CO 2 shadow price can be used when fixing carbon tax rates, in environmental cost-benefit analysis and in ascertaining an initial market price for a trading system. The water industry could play an important role in the reduction of greenhouse gas (GHG) emissions. This paper estimates the shadow price of CO 2 for a sample of wastewater treatment plants (WWTPs), using a parametric quadratic directional distance function. Following this, in a sensitivity analysis, the paper evaluates the impact of different settings of directional vectors on the shadow prices. Applying the Mann–Whitney and Kruskal–Wallis non-parametric tests, factors affecting CO 2 prices are investigated. The variation of CO 2 shadow prices across the WWTPs evaluated argues in favour of a market-based approach to CO 2 mitigation as opposed to command-and-control regulation. The paper argues that the estimation of the shadow price of CO 2 for non-power enterprises can provide incentives for reducing GHG emissions

  8. Repeated stimulation, inter-stimulus interval and inter-electrode distance alters muscle contractile properties as measured by Tensiomyography.

    Directory of Open Access Journals (Sweden)

    Hannah V Wilson

    Full Text Available The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG has not been published.To investigate the; (1 reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm, (2 effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude and contraction time (Tc, (3 the effect of changing inter-electrode distance on Dm and Tc.Within subject, repeated measures.10 participants for each objective.Dm and Tc of the rectus femoris, measured using TMG.The coefficient of variance (CV and the intra-class correlation (ICC of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively.Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles.

  9. Conception and development of an optical methodology applied to long-distance measurement of suspension bridges dynamic displacement

    International Nuclear Information System (INIS)

    Martins, L Lages; Ribeiro, A Silva; Rebordão, J M

    2013-01-01

    This paper describes the conception and development of an optical system applied to suspension bridge structural monitoring, aiming real-time and long-distance measurement of dynamical three-dimensional displacement, namely, in the central section of the main span. The main innovative issues related to this optical approach are described and a comparison with other optical and non-optical measurement systems is performed. Moreover, a computational simulator tool developed for the optical system design and validation of the implemented image processing and calculation algorithms is also presented

  10. Validation, verification and evaluation of a Train to Train Distance Measurement System by means of Colored Petri Nets

    International Nuclear Information System (INIS)

    Song, Haifeng; Liu, Jieyu; Schnieder, Eckehard

    2017-01-01

    Validation, verification and evaluation are necessary processes to assure the safety and functionality of a system before its application in practice. This paper presents a Train to Train Distance Measurement System (TTDMS), which can provide distance information independently from existing onboard equipment. Afterwards, we proposed a new process using Colored Petri Nets to verify the TTDMS system functional safety, as well as to evaluate the system performance. Three main contributions are carried out in the paper: Firstly, this paper proposes a formalized TTDMS model, and the model correctness is validated using state space analysis and simulation-based verification. Secondly, corresponding checking queries are proposed for the purpose of functional safety verification. Further, the TTDMS performance is evaluated by applying parameters in the formal model. Thirdly, the reliability of a functional prototype TTDMS is estimated. It is found that the procedure can cooperate with the system development, and both formal and simulation-based verifications are performed. Using our process to evaluate and verify a system is easier to read and more reliable compared to executable code and mathematical methods. - Highlights: • A new Train to Train Distance Measurement System. • New approach verifying system functional safety and evaluating system performance by means of CPN. • System formalization using the system property concept. • Verification of system functional safety using state space analysis. • Evaluation of system performance applying simulation-based analysis.

  11. Measuring the sustainability of a natural system by using multi-criteria distance function methods: Some critical issues.

    Science.gov (United States)

    Diaz-Balteiro, L; Belavenutti, P; Ezquerro, M; González-Pachón, J; Ribeiro Nobre, S; Romero, C

    2018-05-15

    There is an important body of literature using multi-criteria distance function methods for the aggregation of a battery of sustainability indicators in order to obtain a composite index. This index is considered to be a proxy of the sustainability goodness of a natural system. Although this approach has been profusely used in the literature, it is not exempt from difficulties and potential pitfalls. Thus, in this paper, a significant number of critical issues have been identified showing different procedures capable of avoiding, or at least of mitigating, the inherent potential pitfalls associated with each one. The recommendations made in the paper could increase the theoretical soundness of the multi-criteria distance function methods when this type of approach is applied in the sustainability field, thus increasing the accuracy and realism of the sustainability measurements obtained. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Measurement Errors Arising When Using Distances in Microeconometric Modelling and the Individuals’ Position Is Geo-Masked for Confidentiality

    Directory of Open Access Journals (Sweden)

    Giuseppe Arbia

    2015-10-01

    Full Text Available In many microeconometric models we use distances. For instance, in modelling the individual behavior in labor economics or in health studies, the distance from a relevant point of interest (such as a hospital or a workplace is often used as a predictor in a regression framework. However, in order to preserve confidentiality, spatial micro-data are often geo-masked, thus reducing their quality and dramatically distorting the inferential conclusions. In particular in this case, a measurement error is introduced in the independent variable which negatively affects the properties of the estimators. This paper studies these negative effects, discusses their consequences, and suggests possible interpretations and directions to data producers, end users, and practitioners.

  13. Encyclopedia of distances

    CERN Document Server

    Deza, Michel Marie

    2016-01-01

    This 4th edition of the leading reference volume on distance metrics is characterized by updated and rewritten sections on some items suggested by experts and readers, as well a general streamlining of content and the addition of essential new topics. Though the structure remains unchanged, the new edition also explores recent advances in the use of distances and metrics for e.g. generalized distances, probability theory, graph theory, coding theory, data analysis. New topics in the purely mathematical sections include e.g. the Vitanyi multiset-metric, algebraic point-conic distance, triangular ratio metric, Rossi-Hamming metric, Taneja distance, spectral semimetric between graphs, channel metrization, and Maryland bridge distance. The multidisciplinary sections have also been supplemented with new topics, including: dynamic time wrapping distance, memory distance, allometry, atmospheric depth, elliptic orbit distance, VLBI distance measurements, the astronomical system of units, and walkability distance. Lea...

  14. Measuring the distance from saddle points and driving to locate them over quantum control landscapes

    International Nuclear Information System (INIS)

    Sun, Qiuyang; Riviello, Gregory; Rabitz, Herschel; Wu, Re-Bing

    2015-01-01

    Optimal control of quantum phenomena involves the introduction of a cost functional J to characterize the degree of achieving a physical objective by a chosen shaped electromagnetic field. The cost functional dependence upon the control forms a control landscape. Two theoretically important canonical cases are the landscapes associated with seeking to achieve either a physical observable or a unitary transformation. Upon satisfaction of particular assumptions, both landscapes are analytically known to be trap-free, yet possess saddle points at precise suboptimal J values. The presence of saddles on the landscapes can influence the effort needed to find an optimal field. As a foundation to future algorithm development and analyzes, we define metrics that identify the ‘distance’ from a given saddle based on the sufficient and necessary conditions for the existence of the saddles. Algorithms are introduced utilizing the metrics to find a control such that the dynamics arrive at a targeted saddle. The saddle distance metric and saddle-seeking methodology is tested numerically in several model systems. (paper)

  15. Optimization methods of pulse-to-pulse alignment using femtosecond pulse laser based on temporal coherence function for practical distance measurement

    Science.gov (United States)

    Liu, Yang; Yang, Linghui; Guo, Yin; Lin, Jiarui; Cui, Pengfei; Zhu, Jigui

    2018-02-01

    An interferometer technique based on temporal coherence function of femtosecond pulses is demonstrated for practical distance measurement. Here, the pulse-to-pulse alignment is analyzed for large delay distance measurement. Firstly, a temporal coherence function model between two femtosecond pulses is developed in the time domain for the dispersive unbalanced Michelson interferometer. Then, according to this model, the fringes analysis and the envelope extraction process are discussed. Meanwhile, optimization methods of pulse-to-pulse alignment for practical long distance measurement are presented. The order of the curve fitting and the selection of points for envelope extraction are analyzed. Furthermore, an averaging method based on the symmetry of the coherence function is demonstrated. Finally, the performance of the proposed methods is evaluated in the absolute distance measurement of 20 μ m with path length difference of 9 m. The improvement of standard deviation in experimental results shows that these approaches have the potential for practical distance measurement.

  16. An optical distance sensor : tilt robust differential confocal measurement with mm range and nm uncertainty

    NARCIS (Netherlands)

    Cacace, L.A.

    2009-01-01

    Compared with conventional high-end optical systems, application of freeform optics offers many advantages. Their widespread use, however, is held back by the lack of a suitable measurement method.The NANOMEFOS project aims at realizing a universal freeform measurement machine to fill that void.The

  17. Measuring dispersal as distance-dependent recruitment rates: testing the performance of DDRR on simulated data.

    NARCIS (Netherlands)

    Van Noordwijk, A.J.

    2011-01-01

    Dispersal is an important process in ecology, but its measurement is difficult. In particular, natal dispersal— the net movement between site of birth and site of first reproduction—is important, since it determines population structure. Using simulated data, I study the claim that measuring

  18. A simple method of measuring tibial tubercle to trochlear groove distance on MRI: description of a novel and reliable technique.

    Science.gov (United States)

    Camp, Christopher L; Heidenreich, Mark J; Dahm, Diane L; Bond, Jeffrey R; Collins, Mark S; Krych, Aaron J

    2016-03-01

    Tibial tubercle-trochlear groove (TT-TG) distance is a variable that helps guide surgical decision-making in patients with patellar instability. The purpose of this study was to compare the accuracy and reliability of an MRI TT-TG measuring technique using a simple external alignment method to a previously validated gold standard technique that requires advanced software read by radiologists. TT-TG was calculated by MRI on 59 knees with a clinical diagnosis of patellar instability in a blinded and randomized fashion by two musculoskeletal radiologists using advanced software and by two orthopaedists using the study technique which utilizes measurements taken on a simple electronic imaging platform. Interrater reliability between the two radiologists and the two orthopaedists and intermethods reliability between the two techniques were calculated using interclass correlation coefficients (ICC) and concordance correlation coefficients (CCC). ICC and CCC values greater than 0.75 were considered to represent excellent agreement. The mean TT-TG distance was 14.7 mm (Standard Deviation (SD) 4.87 mm) and 15.4 mm (SD 5.41) as measured by the radiologists and orthopaedists, respectively. Excellent interobserver agreement was noted between the radiologists (ICC 0.941; CCC 0.941), the orthopaedists (ICC 0.978; CCC 0.976), and the two techniques (ICC 0.941; CCC 0.933). The simple TT-TG distance measurement technique analysed in this study resulted in excellent agreement and reliability as compared to the gold standard technique. This method can predictably be performed by orthopaedic surgeons without advanced radiologic software. II.

  19. The Distance Standard Deviation

    OpenAIRE

    Edelmann, Dominic; Richards, Donald; Vogel, Daniel

    2017-01-01

    The distance standard deviation, which arises in distance correlation analysis of multivariate data, is studied as a measure of spread. New representations for the distance standard deviation are obtained in terms of Gini's mean difference and in terms of the moments of spacings of order statistics. Inequalities for the distance variance are derived, proving that the distance standard deviation is bounded above by the classical standard deviation and by Gini's mean difference. Further, it is ...

  20. Role of effective distance in the fission mechanism study by the double-energy measurement for uranium isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Hiroshi; Saito, Tadashi; Takahashi, Naruto [Osaka Univ., Suita (Japan)] [and others

    1997-09-01

    Fission product kinetic energies were measured by the double-energy method for thermal-neutron fission of {sup 235,233}U and proton-induced fission of {sup 238}U at the 15.8-MeV excitation. From the obtained energy-mass correlation data, the kinetic-energy distribution was constructed from each mass bin to evaluate the first moment of the kinetic energy for a given fragment mass. The resulting kinetic energy was then converted to the effective distance between the charge centers at the moment of scission. The effective distances deduced for the proton-induced fission was concluded to be classified into two constant values, one for asymmetric and the other for symmetric mode, irrespective of the mass though an additional component was further extracted in the asymmetric mass region. This indicates that the fission takes place via two well-defined saddles, followed by the random neck rupture. On the contrary, the effective distances obtained for thermal-neutron induced fission turned out to lie along the contour line at the same level as the equilibrium deformation in the two-dimensional potential map. This strongly suggests that it is essentially a barrier-penetrating type of fission rather than the over-barrier fission. (author). 73 refs.

  1. Role of effective distance in the fission mechanism study by the double-energy measurement for uranium isotopes

    International Nuclear Information System (INIS)

    Baba, Hiroshi; Saito, Tadashi; Takahashi, Naruto

    1997-01-01

    Fission product kinetic energies were measured by the double-energy method for thermal-neutron fission of 235,233 U and proton-induced fission of 238 U at the 15.8-MeV excitation. From the obtained energy-mass correlation data, the kinetic-energy distribution was constructed from each mass bin to evaluate the first moment of the kinetic energy for a given fragment mass. The resulting kinetic energy was then converted to the effective distance between the charge centers at the moment of scission. The effective distances deduced for the proton-induced fission was concluded to be classified into two constant values, one for asymmetric and the other for symmetric mode, irrespective of the mass though an additional component was further extracted in the asymmetric mass region. This indicates that the fission takes place via two well-defined saddles, followed by the random neck rupture. On the contrary, the effective distances obtained for thermal-neutron induced fission turned out to lie along the contour line at the same level as the equilibrium deformation in the two-dimensional potential map. This strongly suggests that it is essentially a barrier-penetrating type of fission rather than the over-barrier fission. (author). 73 refs

  2. Enhancing Diffusion MRI Measures By Integrating Grey and White Matter Morphometry With Hyperbolic Wasserstein Distance

    Science.gov (United States)

    Zhang, Wen; Shi, Jie; Yu, Jun; Zhan, Liang; Thompson, Paul M.; Wang, Yalin

    2017-01-01

    In order to improve the preclinical diagnose of Alzheimer's disease (AD), there is a great deal of interest in analyzing the AD related brain structural changes with magnetic resonance image (MRI) analyses. As the major features, variation of the structural connectivity and the cortical surface morphometry provide different views of structural changes to determine whether AD is present on presymptomatic patients. However, the large scale tensor-valued information and relatively low imaging resolution in diffusion MRI (dMRI) have created huge challenges for analysis. In this paper, we propose a novel framework that improves dMRI analysis power by fusing cortical surface morphometry features from structural MRI (sMRI). We first compute the hyperbolic harmonic maps between cortical surfaces with the landmark constraints thus to precisely evaluate surface tensor-based morphometry. Meanwhile, the graph-based analysis of structural connectivity derived from dMRI is conducted. Next, we fuse these two features via the optimal mass transportation (OMT) and eventually the Wasserstein distance (WD) based single image index is computed as a potential clinical multimodality imaging score. We apply our framework to brain images of 20 AD patients and 20 matched healthy controls, randomly chosen from the Alzheimer's Disease Neuroimaging Initiative (AD-NI2) dataset. Our preliminary experimental results of group classification outperformed those of some other single dMRI-based features, such as regional hippocampal volume, mean scores of fractional anisotropy (FA) and mean axial (MD). The novel image fusion pipeline and simple imaging score of structural changes may benefit the preclinical AD and AD prevention research. PMID:28936280

  3. Static and Dynamic Accuracy of an Innovative Miniaturized Wearable Platform for Short Range Distance Measurements for Human Movement Applications

    Directory of Open Access Journals (Sweden)

    Stefano Bertuletti

    2017-06-01

    Full Text Available Magneto-inertial measurement units (MIMU are a suitable solution to assess human motor performance both indoors and outdoors. However, relevant quantities such as step width and base of support, which play an important role in gait stability, cannot be directly measured using MIMU alone. To overcome this limitation, we developed a wearable platform specifically designed for human movement analysis applications, which integrates a MIMU and an Infrared Time-of-Flight proximity sensor (IR-ToF, allowing for the estimate of inter-object distance. We proposed a thorough testing protocol for evaluating the IR-ToF sensor performances under experimental conditions resembling those encountered during gait. In particular, we tested the sensor performance for different (i target colors; (ii sensor-target distances (up to 200 mm and (iii sensor-target angles of incidence (AoI (up to 60 ∘ . Both static and dynamic conditions were analyzed. A pendulum, simulating the oscillation of a human leg, was used to generate highly repeatable oscillations with a maximum angular velocity of 6 rad/s. Results showed that the IR-ToF proximity sensor was not sensitive to variations of both distance and target color (except for black. Conversely, a relationship between error magnitude and AoI values was found. For AoI equal to 0 ∘ , the IR-ToF sensor performed equally well both in static and dynamic acquisitions with a distance mean absolute error <1.5 mm. Errors increased up to 3.6 mm (static and 11.9 mm (dynamic for AoI equal to ± 30 ∘ , and up to 7.8 mm (static and 25.6 mm (dynamic for AoI equal to ± 60 ∘ . In addition, the wearable platform was used during a preliminary experiment for the estimation of the inter-foot distance on a single healthy subject while walking. In conclusion, the combination of magneto-inertial unit and IR-ToF technology represents a valuable alternative solution in terms of accuracy, sampling frequency, dimension and power consumption

  4. Distance Learning

    National Research Council Canada - National Science Library

    Braddock, Joseph

    1997-01-01

    A study reviewing the existing Army Distance Learning Plan (ADLP) and current Distance Learning practices, with a focus on the Army's training and educational challenges and the benefits of applying Distance Learning techniques...

  5. Distance Protection Impedance Measurement for Inhomogeneous Multiple-Circuit 400/150 kV Transmission Lines with Shared Towers

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Sigurbjörnsson, Ragnar; Bukh, Bjarne

    2016-01-01

    are interconnected in a simple way but via transformers and infeed from remaining parts of the network. Distance relay measured fault loop impedance shows wide ranges of variations for both phase-phase loops as well as phase-earth loops. No simple relations exist. Simulation models can be used to study fault loop...... impedance for combined faults and thereby shed light on relay trips. This study uses actual fault records, analytical method and PSCAD simulation studies to analyse combined faults in an existing 400 and 150 kV transmission line owned by Danish TSO Energinet.dk. The results clearly show that an accurate...

  6. All-silicon Michelson instrument on chip: Distance and surface profile measurement and prospects for visible light spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Malak, M.; Marty, F.; Bourouina, T. [Universite Paris-Est, Laboratoire ESYCOM, ESIEE Paris, Cite Descartes, 2 Boulevard Blaise Pascal, 93162 Noisy-le-Grand Cedex (France); Nouira, H.; Vailleau, G. [Laboratoire National de Metrologie et d' Essais, 1 rue Gaston Boissier, 75724 Paris Cedex 15 (France)

    2013-04-08

    A miniature Michelson interferometer is analyzed theoretically and experimentally. The fabricated micro-interferometer is incorporated at the tip of a monolithic silicon probe to achieve contactless distance measurements and surface profilometry. For infrared operation, two approaches are studied, based on the use of monochromatic light and wavelength sweep, respectively. A theoretical model is devised to depict the system characteristics taking into account Gaussian beam divergence and light spot size. Furthermore, preliminary results using visible light demonstrate operation of the probe as a visible light spectrometer, despite silicon absorbance, thanks to the micrometer thickness involved in the beam splitter.

  7. All-silicon Michelson instrument on chip: Distance and surface profile measurement and prospects for visible light spectrometry

    International Nuclear Information System (INIS)

    Malak, M.; Marty, F.; Bourouina, T.; Nouira, H.; Vailleau, G.

    2013-01-01

    A miniature Michelson interferometer is analyzed theoretically and experimentally. The fabricated micro-interferometer is incorporated at the tip of a monolithic silicon probe to achieve contactless distance measurements and surface profilometry. For infrared operation, two approaches are studied, based on the use of monochromatic light and wavelength sweep, respectively. A theoretical model is devised to depict the system characteristics taking into account Gaussian beam divergence and light spot size. Furthermore, preliminary results using visible light demonstrate operation of the probe as a visible light spectrometer, despite silicon absorbance, thanks to the micrometer thickness involved in the beam splitter.

  8. High accuracy subwavelength distance measurements: A variable-angle standing-wave total-internal-reflection optical microscope

    International Nuclear Information System (INIS)

    Haynie, A.; Min, T.-J.; Luan, L.; Mu, W.; Ketterson, J. B.

    2009-01-01

    We describe an extension of the total-internal-reflection microscopy technique that permits direct in-plane distance measurements with high accuracy (<10 nm) over a wide range of separations. This high position accuracy arises from the creation of a standing evanescent wave and the ability to sweep the nodal positions (intensity minima of the standing wave) in a controlled manner via both the incident angle and the relative phase of the incoming laser beams. Some control over the vertical resolution is available through the ability to scan the incoming angle and with it the evanescent penetration depth.

  9. Bonner Prize Address: Measurements of the electromagnetic properties of nucleons and nuclei at short distance scales

    Science.gov (United States)

    Raymond, Arnold

    2000-04-01

    The talk will present the story of a series of experiments, beginning in 1973 and continuing today, that have measured the internal structure of nuclei and the nucleons using high energy beams of electrons and photons at the Stanford Linear Accelerator Center. These experiments have probed nuclear and nucleon structure in the energy and momentum transfer region where the meson-nucleon description merges with the quark-gluon picture. The experiments have worked at the border between nuclear and particle physics, and were conducted by large collaborative teams. Some were carried out in the context of a special program, called NPAS (Nuclear Physics at SLAC). The early results from these measurements helped stimulate the ideas and helped train and motivate the physicists who went on to build the Jefferson Laboratory. A brief summary of some highlights from the early measurements and updates on recent results will be given.

  10. Measurements of tritium (HTO, TFWT, OBT) in environmental samples at varying distances from a nuclear generating station

    International Nuclear Information System (INIS)

    Kotzer, T.G.; Workman, W.J.G.

    1999-12-01

    Concentrations of tritium have been measured in environmental samples (vegetation, water, soil, air) from sites distal and proximal to a CANDU nuclear generating station in Southern Ontario (OPG-Pickering). Levels of tissue-free water tritium (TFWT) and organically bound tritium (OBT) in vegetation are as high as 24,000 TU immediately adjacent to the nuclear generating station and rapidly decrease to levels of tritium which are comparable to natural ambient concentrations for tritium in the environment (approximately ≤ 60 TU). Tritium concentrations (OBT, TFTW) have also been measured in samples of vegetation and tree rings growing substantial distances away from nuclear generating stations and are within a factor of 1 to 2 of the ambient levels of tritium measured in precipitation in several parts of Canada (approximately ≤30 TU). (author)

  11. Measurements of tritium (HTO, TFWT, OBT) in environmental samples at varying distances from a nuclear generating station

    Energy Technology Data Exchange (ETDEWEB)

    Kotzer, T.G.; Workman, W.J.G

    1999-12-01

    Concentrations of tritium have been measured in environmental samples (vegetation, water, soil, air) from sites distal and proximal to a CANDU nuclear generating station in Southern Ontario (OPG-Pickering). Levels of tissue-free water tritium (TFWT) and organically bound tritium (OBT) in vegetation are as high as 24,000 TU immediately adjacent to the nuclear generating station and rapidly decrease to levels of tritium which are comparable to natural ambient concentrations for tritium in the environment (approximately {<=} 60 TU). Tritium concentrations (OBT, TFTW) have also been measured in samples of vegetation and tree rings growing substantial distances away from nuclear generating stations and are within a factor of 1 to 2 of the ambient levels of tritium measured in precipitation in several parts of Canada (approximately {<=}30 TU). (author)

  12. The influence of probe fiber distance on laser Doppler perfusion monitoring measurements

    NARCIS (Netherlands)

    Morales, F; Graaff, R; Smit, AJ; Gush, R; Rakhorst, G

    2003-01-01

    Laser Doppler perfusion monitoring (LDPM) is a noninvasive technique for monitoring skin microcirculation. The aim of this article was to investigate the influence of fiber separation on clinical LDPM measurements. A dual-channel LDPM system was used in combination with a probe that consists of two

  13. Ultra-Precise Measurement of Distance by Fabry-Perot Resonator

    Czech Academy of Sciences Publication Activity Database

    Číp, Ondřej; Petrů, František; Lazar, Josef; Buchta, Zdeněk

    T118, - (2005), s. 45-47 ISSN 0031-8949 R&D Projects: GA ČR(CZ) GP102/02/P122 Keywords : length measurements * laser interferometer * optical resonator Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.661, year: 2004

  14. Towards measurement of the Casimir force between parallel plates separated at sub-mircon distance

    NARCIS (Netherlands)

    Syed Nawazuddin, M.B.; Lammerink, Theodorus S.J.; Wiegerink, Remco J.; Berenschot, Johan W.; de Boer, Meint J.; Elwenspoek, Michael Curt

    2011-01-01

    Ever since its prediction, experimental investigation of the Casimir force has been of great scientific interest. Many research groups have successfully attempted quantifying the force with different device geometries; however measurement of the Casimir force between parallel plates with sub-micron

  15. Striking Distance Determined From High-Speed Videos and Measured Currents in Negative Cloud-to-Ground Lightning

    Science.gov (United States)

    Visacro, Silverio; Guimaraes, Miguel; Murta Vale, Maria Helena

    2017-12-01

    First and subsequent return strokes' striking distances (SDs) were determined for negative cloud-to-ground flashes from high-speed videos exhibiting the development of positive and negative leaders and the pre-return stroke phase of currents measured along a short tower. In order to improve the results, a new criterion was used for the initiation and propagation of the sustained upward connecting leader, consisting of a 4 A continuous current threshold. An advanced approach developed from the combined use of this criterion and a reverse propagation procedure, which considers the calculated propagation speeds of the leaders, was applied and revealed that SDs determined solely from the first video frame showing the upward leader can be significantly underestimated. An original approach was proposed for a rough estimate of first strokes' SD using solely records of current. This approach combines the 4 A criterion and a representative composite three-dimensional propagation speed of 0.34 × 106 m/s for the leaders in the last 300 m propagated distance. SDs determined under this approach showed to be consistent with those of the advanced procedure. This approach was applied to determine the SD of 17 first return strokes of negative flashes measured at MCS, covering a wide peak-current range, from 18 to 153 kA. The estimated SDs exhibit very high dispersion and reveal great differences in relation to the SDs estimated for subsequent return strokes and strokes in triggered lightning.

  16. The distance between Mars and Venus: measuring global sex differences in personality.

    Science.gov (United States)

    Del Giudice, Marco; Booth, Tom; Irwing, Paul

    2012-01-01

    Sex differences in personality are believed to be comparatively small. However, research in this area has suffered from significant methodological limitations. We advance a set of guidelines for overcoming those limitations: (a) measure personality with a higher resolution than that afforded by the Big Five; (b) estimate sex differences on latent factors; and (c) assess global sex differences with multivariate effect sizes. We then apply these guidelines to a large, representative adult sample, and obtain what is presently the best estimate of global sex differences in personality. Personality measures were obtained from a large US sample (N = 10,261) with the 16PF Questionnaire. Multigroup latent variable modeling was used to estimate sex differences on individual personality dimensions, which were then aggregated to yield a multivariate effect size (Mahalanobis D). We found a global effect size D = 2.71, corresponding to an overlap of only 10% between the male and female distributions. Even excluding the factor showing the largest univariate ES, the global effect size was D = 1.71 (24% overlap). These are extremely large differences by psychological standards. The idea that there are only minor differences between the personality profiles of males and females should be rejected as based on inadequate methodology.

  17. Validity and reliability of GPS and LPS for measuring distances covered and sprint mechanical properties in team sports.

    Science.gov (United States)

    Hoppe, Matthias W; Baumgart, Christian; Polglaze, Ted; Freiwald, Jürgen

    2018-01-01

    This study aimed to investigate the validity and reliability of global (GPS) and local (LPS) positioning systems for measuring distances covered and sprint mechanical properties in team sports. Here, we evaluated two recently released 18 Hz GPS and 20 Hz LPS technologies together with one established 10 Hz GPS technology. Six male athletes (age: 27±2 years; VO2max: 48.8±4.7 ml/min/kg) performed outdoors on 10 trials of a team sport-specific circuit that was equipped with double-light timing gates. The circuit included various walking, jogging, and sprinting sections that were performed either in straight-lines or with changes of direction. During the circuit, athletes wore two devices of each positioning system. From the reported and filtered velocity data, the distances covered and sprint mechanical properties (i.e., the theoretical maximal horizontal velocity, force, and power output) were computed. The sprint mechanical properties were modeled via an inverse dynamic approach applied to the center of mass. The validity was determined by comparing the measured and criterion data via the typical error of estimate (TEE), whereas the reliability was examined by comparing the two devices of each technology (i.e., the between-device reliability) via the coefficient of variation (CV). Outliers due to measurement errors were statistically identified and excluded from validity and reliability analyses. The 18 Hz GPS showed better validity and reliability for determining the distances covered (TEE: 1.6-8.0%; CV: 1.1-5.1%) and sprint mechanical properties (TEE: 4.5-14.3%; CV: 3.1-7.5%) than the 10 Hz GPS (TEE: 3.0-12.9%; CV: 2.5-13.0% and TEE: 4.1-23.1%; CV: 3.3-20.0%). However, the 20 Hz LPS demonstrated superior validity and reliability overall (TEE: 1.0-6.0%; CV: 0.7-5.0% and TEE: 2.1-9.2%; CV: 1.6-7.3%). For the 10 Hz GPS, 18 Hz GPS, and 20 Hz LPS, the relative loss of data sets due to measurement errors was 10.0%, 20.0%, and 15.8%, respectively. This study shows that

  18. Correlation between inter-spin interaction and molecular dynamics of organic radicals in organic 1D nanochannels

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hirokazu [Department of Chemistry, College of Humanities and Sciences, Nihon University 3-25-40, Sakura-jo-sui, Setagaya-ku, Tokyo, 156-8550 (Japan)

    2015-12-31

    One-dimensional (1D) molecular chains of 4-substituted-2,2,6,6-tetramethyl-1-piperidinyloxyl (4-X-TEMPO) radicals were constructed in the crystalline 1D nanochannels of 2,4,6-tris(4-chlorophenoxy)-1,3,5-triazine (CLPOT) used as a template. The ESR spectra of CLPOT inclusion compounds (ICs) using 4-X-TEMPO were examined on the basis of spectral simulation using EasySpin program package for simulating and fitting ESR spectra. The ESR spectra of [(CLPOT){sub 2}-(TEMPO){sub 1.0}] IC were isotropic in the total range of temperatures. The peak-to-peak line width (ΔB{sub pp}) became monotonically narrower from 2.8 to 1.3 mT with increase in temperature in the range of 4.2–298 K. The effect of the rotational diffusion motion of TEMPO radicals in the CLPOT nanochannels for the inter-spin interaction of the [(CLPOT){sub 2}-(TEMPO){sub 1.0}] IC was found to be smaller than the case of [(TPP){sub 2}−(TEMPO){sub 1.0}] IC (TPP = tris(o-phenylenedioxy)cyclotriphosphazene) reported in our previous study. The ΔB{sub pp} of the [(CLPOT){sub 2}-(TEMPO){sub 1.0}] IC in the whole range of temperatures was much narrower than the estimation to be based on the Van Vleck’s formula for the second moment of the rigid lattice model where the electron spin can be considered as fixed; 11 mT of Gaussian line-width component. This suggests the possibility of exchange narrowing in the 1D organic-radical chains of the [(CLPOT){sub 2}-(TEMPO){sub 1.0}] IC. On the other hand, the ESR spectra of [(CLPOT){sub 2}-(MeO-TEMPO){sub 0.41}] IC (MeO-TEMPO = 4-methoxy-TEMPO) were reproduced by a superposition of major broad isotropic adsorption line and minor temperature-dependent modulated triplet component. This suggests that the IC has the part of 1D organic-radical chains and MeO-TEMPO molecules isolated in the CLPOT nanochannels.

  19. Transforaminal Lumbar Interbody Fusion with Rigid Interspinous Process Fixation: A Learning Curve Analysis of a Surgeon Team's First 74 Cases.

    Science.gov (United States)

    Doherty, Patrick; Welch, Arthur; Tharpe, Jason; Moore, Camille; Ferry, Chris

    2017-05-30

    Studies have shown that a significant learning curve may be associated with adopting minimally invasive transforaminal lumbar interbody fusion (MIS TLIF) with bilateral pedicle screw fixation (BPSF). Accordingly, several hybrid TLIF techniques have been proposed as surrogates to the accepted BPSF technique, asserting that less/fewer fixation(s) or less disruptive fixation may decrease the learning curve while still maintaining the minimally disruptive benefits. TLIF with interspinous process fixation (ISPF) is one such surrogate procedure. However, despite perceived ease of adaptability given the favorable proximity of the spinous processes, no evidence exists demonstrating whether or not the technique may possess its own inherent learning curve. The purpose of this study was to determine whether an intraoperative learning curve for one- and two-level TLIF + ISPF may exist for a single lead surgeon. Seventy-four consecutive patients who received one- or two-Level TLIF with rigid ISPF by a single lead surgeon were retrospectively reviewed. It was the first TLIF + ISPF case series for the lead surgeon. Intraoperative blood loss (EBL), hospitalization length-of-stay (LOS), fluoroscopy time, and postoperative complications were collected. EBL, LOS, and fluoroscopy time were modeled as a function of case number using multiple linear regression methods. A change point was included in each model to allow the trajectory of the outcomes to change during the duration of the case series. These change points were determined using profile likelihood methods. Models were fit using the maximum likelihood estimates for the change points. Age, sex, body mass index (BMI), and the number of treated levels were included as covariates. EBL, LOS, and fluoroscopy time did not significantly differ by age, sex, or BMI (p ≥ 0.12). Only EBL differed significantly by the number of levels (p = 0.026). The case number was not a significant predictor of EBL, LOS, or fluoroscopy time (p ≥ 0

  20. Comparative Study of Nei�s D with other Genetic Distance Measures between Barak Valley Muslims and other Nations for ABO Locus

    Directory of Open Access Journals (Sweden)

    Supriyo CHAKRABORTY

    2012-02-01

    Full Text Available Quantification of the genetic distance between populations is essential in many genetic research programs. Several formulae were proposed for the estimation of genetic distance between populations using gene frequency data. But the selection of a suitable measure for estimating genetic distance between real-world human populations is a very difficult task despite the widely used measure Neis D. The present study was undertaken to estimate the genetic distance between Barak Valley Muslims (BVM and other twenty-four nations using seven different measures with ABO blood group gene frequency data for comparative analysis and to estimate the correlation coefficients between distance measures and to work out the linear regression equations. Seven genetic distance measures namely Neis D, Neis Nm, La, Neis Da, Dc, Re and Neis Ne were estimated between BVM and other 24 nations enroute the journey of mankind from Africa that commenced about 200,000 years ago (www.bradshawfoundation.com. Correlation coefficients between Neis D with other measures were estimated to find out which other genetic distance measures were closely related to Neis D. Neis D showed highly significant (p=0.01 positive correlation with Cavalli-Sforza and Edwards chord distance Dc (0.90, Reynolds Re (0.90, Neis Da (0.74 and Neis Ne (0.63 but negative correlation with Neis Nm and La. Linear regression equations of Neis D with other distance measures were estimated as Da = -0.80 + 1.34D, Dc = 1.91 + 4.44D, Re = -0.51 + 0.24D and Ne = -7.60 + 1.30D.

  1. Lifetime measurement in {sup 168}Yb using the recoil distance Doppler shift (RDDS) method

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Michael; Moeller, Oliver; Pietralla, Norbert [TU Darmstadt (Germany); Dewald, Alfred; Pissulla, Thomas [Universitaet Koeln (Germany); Petkov, Pavel [Universitaet Koeln (Germany); INRNE, Bulgarian Academy of Sciences, Sofia (Bulgaria)

    2009-07-01

    In the analysis of coincidence RDDS experiments one uses the Differential Decay Curve (DDC) Method to determine lifetimes of excited states. Experiments with small recoil velocities, thus small Doppler shifts, enforce the use of narrow coincidence gates to determine peak intensities. This results in a loss of statistics. As an alternative to the application of gates, we present the fit of 2-dimensional functions to the {gamma}{gamma} coincidence data. This approach has been studied on data taken in a RDDS measurement for the ground state band of {sup 168}Yb. The {sup 18}O({sup 154}Sm,4n){sup 168}Yb{sup *} fusion evaporation reaction was induced by an 80 MeV ion beam of the tandem accelerator facility in Cologne. The target was mounted in the Cologne coincidence plunger device. Lifetimes from the 4{sub 1}{sup +} to the 10{sub 1}{sup +} states have been extracted. The method is discussed and the results are compared to the CBS rotor model in the context of centrifugal stretching.

  2. Brownian distance covariance

    OpenAIRE

    Székely, Gábor J.; Rizzo, Maria L.

    2010-01-01

    Distance correlation is a new class of multivariate dependence coefficients applicable to random vectors of arbitrary and not necessarily equal dimension. Distance covariance and distance correlation are analogous to product-moment covariance and correlation, but generalize and extend these classical bivariate measures of dependence. Distance correlation characterizes independence: it is zero if and only if the random vectors are independent. The notion of covariance with...

  3. Study of the effect of distance and misalignment between magnetically coupled coils for wireless power transfer in intraocular pressure measurement.

    Science.gov (United States)

    Rendon-Nava, Adrian E; Díaz-Méndez, J Alejandro; Nino-de-Rivera, Luis; Calleja-Arriaga, Wilfrido; Gil-Carrasco, Felix; Díaz-Alonso, Daniela

    2014-01-01

    An analysis of the effect of distance and alignment between two magnetically coupled coils for wireless power transfer in intraocular pressure measurement is presented. For measurement purposes, a system was fabricated consisting of an external device, which is a Maxwell-Wien bridge circuit variation, in charge of transferring energy to a biomedical implant and reading data from it. The biomedical implant is an RLC tank circuit, encapsulated by a polyimide coating. Power transfer was done by magnetic induction coupling method, by placing one of the inductors of the Maxwell-Wien bridge circuit and the inductor of the implant in close proximity. The Maxwell-Wien bridge circuit was biased with a 10 MHz sinusoidal signal. The analysis presented in this paper proves that wireless transmission of power for intraocular pressure measurement is feasible with the measurement system proposed. In order to have a proper inductive coupling link, special care must be taken when placing the two coils in proximity to avoid misalignment between them.

  4. Study of the Effect of Distance and Misalignment between Magnetically Coupled Coils for Wireless Power Transfer in Intraocular Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Adrian E. Rendon-Nava

    2014-01-01

    Full Text Available An analysis of the effect of distance and alignment between two magnetically coupled coils for wireless power transfer in intraocular pressure measurement is presented. For measurement purposes, a system was fabricated consisting of an external device, which is a Maxwell-Wien bridge circuit variation, in charge of transferring energy to a biomedical implant and reading data from it. The biomedical implant is an RLC tank circuit, encapsulated by a polyimide coating. Power transfer was done by magnetic induction coupling method, by placing one of the inductors of the Maxwell-Wien bridge circuit and the inductor of the implant in close proximity. The Maxwell-Wien bridge circuit was biased with a 10 MHz sinusoidal signal. The analysis presented in this paper proves that wireless transmission of power for intraocular pressure measurement is feasible with the measurement system proposed. In order to have a proper inductive coupling link, special care must be taken when placing the two coils in proximity to avoid misalignment between them.

  5. Mapping Rice Cropping Systems in Vietnam Using an NDVI-Based Time-Series Similarity Measurement Based on DTW Distance

    Directory of Open Access Journals (Sweden)

    Xudong Guan

    2016-01-01

    Full Text Available Normalized Difference Vegetation Index (NDVI derived from Moderate Resolution Imaging Spectroradiometer (MODIS time-series data has been widely used in the fields of crop and rice classification. The cloudy and rainy weather characteristics of the monsoon season greatly reduce the likelihood of obtaining high-quality optical remote sensing images. In addition, the diverse crop-planting system in Vietnam also hinders the comparison of NDVI among different crop stages. To address these problems, we apply a Dynamic Time Warping (DTW distance-based similarity measure approach and use the entire yearly NDVI time series to reduce the inaccuracy of classification using a single image. We first de-noise the NDVI time series using S-G filtering based on the TIMESAT software. Then, a standard NDVI time-series base for rice growth is established based on field survey data and Google Earth sample data. NDVI time-series data for each pixel are constructed and the DTW distance with the standard rice growth NDVI time series is calculated. Then, we apply thresholds to extract rice growth areas. A qualitative assessment using statistical data and a spatial assessment using sampled data from the rice-cropping map reveal a high mapping accuracy at the national scale between the statistical data, with the corresponding R2 being as high as 0.809; however, the mapped rice accuracy decreased at the provincial scale due to the reduced number of rice planting areas per province. An analysis of the results indicates that the 500-m resolution MODIS data are limited in terms of mapping scattered rice parcels. The results demonstrate that the DTW-based similarity measure of the NDVI time series can be effectively used to map large-area rice cropping systems with diverse cultivation processes.

  6. Ultrasound measurement of rotator cuff thickness and acromio-humeral distance in the diagnosis of subacromial impingement syndrome of the shoulder.

    Science.gov (United States)

    Cholewinski, Jerzy J; Kusz, Damian J; Wojciechowski, Piotr; Cielinski, Lukasz S; Zoladz, Miroslaw P

    2008-04-01

    The usefulness of ultrasound measurements in the diagnosis of the subacromial impingement syndrome of the shoulder was evaluated. Fifty-seven patients with unilateral symptoms of the impingement syndrome underwent ultrasound examination of both shoulder joints, which included assessment of rotator cuff integrity, measurement of rotator cuff thickness and the distance between the infero-lateral edge of acromion and the apex of the greater tuberosity of humerus (AGT distance) in the standard ultrasonographic positions. As a control group, 36 volunteers (72 shoulders) with no history of shoulder pain were examined sonographically. Ultrasonographic assessment of humeral head elevation, measured as the AGT distance, proved to be useful in establishing the diagnosis of the subacromial impingement syndrome of the shoulder. A difference in rotator cuff thickness of more than 1.1 mm and a difference in the AGT distance of more than 2.1 mm between both shoulder joints may reflect dysfunction of rotator cuff muscles.

  7. Correcting for variable laser-target distances of laser-induced breakdown spectroscopy measurements with ChemCam using emission lines of Martian dust spectra

    Energy Technology Data Exchange (ETDEWEB)

    Melikechi, N.; Mezzacappa, A. [Optical Science Center for Applied Research, Delaware State University, Dover, DE (United States); Cousin, A.; Lanza, N.L. [Los Alamos National Laboratory, Los Alamos, NM (United States); Lasue, J. [Institut de Recherche en Astophysique et Planetologie (IRAP), Universite' Paul Sabatier, Toulouse (France); Clegg, S.M. [Los Alamos National Laboratory, Los Alamos, NM (United States); Berger, G. [Institut de Recherche en Astophysique et Planetologie (IRAP), Universite' Paul Sabatier, Toulouse (France); Wiens, R.C. [Los Alamos National Laboratory, Los Alamos, NM (United States); Maurice, S. [Institut de Recherche en Astophysique et Planetologie (IRAP), Universite' Paul Sabatier, Toulouse (France); Tokar, R.L.; Bender, S. [Planetary Science Institute, Flagstaff, AZ (United States); Forni, O. [Institut de Recherche en Astophysique et Planetologie (IRAP), Universite' Paul Sabatier, Toulouse (France); Breves, E.A.; Dyar, M.D. [Dept. of Astronomy, Mount Holyoke College, South Hadley, MA (United States); Frydenvang, J. [The Niels Bohr Institute, University of Copenhagen, Copenhagen (Denmark); Delapp, D. [Los Alamos National Laboratory, Los Alamos, NM (United States); Gasnault, O. [Institut de Recherche en Astophysique et Planetologie (IRAP), Universite' Paul Sabatier, Toulouse (France); Newsom, H.; Ollila, A.M. [Earth and Planetary Sciences, University of New Mexico, Alburquerque, NM (United States); Lewin, E. [Institut des Sciences de la Terre, Universite Grenoble l-CNRS, Grenoble (France); and others

    2014-06-01

    As part of the Mars Science Laboratory, the ChemCam instrument acquires remote laser induced breakdown spectra at distances that vary between 1.56 m and 7 m. This variation in distance affects the intensities of the measured LIBS emission lines in non-trivial ways. To determine the behavior of a LIBS emission line with distance, it is necessary to separate the effects of many parameters such as laser energy, laser spot size, target homogeneity, and optical collection efficiency. These parameters may be controlled in a laboratory on Earth but for field applications or in space this is a challenge. In this paper, we show that carefully selected ChemCam LIBS emission lines acquired from the Martian dust can be used to build an internal proxy spectroscopic standard. This in turn, allows for a direct measurement of the effects of the distance of various LIBS emission lines and hence can be used to correct ChemCam LIBS spectra for distance variations. When tested on pre-launch LIBS calibration data acquired under Martian-like conditions and with controlled and well-calibrated targets, this approach yields much improved agreement between targets observed at various distances. This work lays the foundation for future implementation of automated routines to correct ChemCam spectra for differences caused by variable distance. - Highlights: • Selected Martian dust emission lines are used to correct for variable laser-target distances. • The correction model yields improved agreement between targets observed at various distances. • The impact of the model reduces the bias between predicted and actual compositions by as much as 70%. • When implemented, the model will yield spectral corrections for various ChemCam measurements. • This work is a foundation to perform novel stand-off LIBS measurements on Earth and other planets.

  8. Comparison of a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography.

    Science.gov (United States)

    Stuberg, W A; Colerick, V L; Blanke, D J; Bruce, W

    1988-08-01

    The purpose of this study was to compare a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography in a gait analysis laboratory. Ten children with a diagnosis of cerebral palsy (means age = 8.8 +/- 2.7 years) and 9 healthy children (means age = 8.9 +/- 2.4 years) participated in the study. Stride length, walking velocity, and goniometric measurements of the hip, knee, and ankle were recorded using the two gait analysis methods. A multivariate analysis of variance was used to determine significant differences between the data collected using the two methods. Pearson product-moment correlation coefficients were determined to examine the relationship between the measurements recorded by the two methods. The consistency of performance of the subjects during walking was examined by intraclass correlation coefficients. No significant differences were found between the methods for the variables studied. Pearson product-moment correlation coefficients ranged from .79 to .95, and intraclass coefficients ranged from .89 to .97. The clinical gait analysis method was found to be a valid tool in comparison with 16-mm cinematography for the variables that were studied.

  9. MRI performed on dedicated knee coils is inaccurate for the measurement of tibial tubercle trochlear groove distance

    International Nuclear Information System (INIS)

    Aarvold, A.; Pope, A.; Sakthivel, V.K.; Ayer, R.V.

    2014-01-01

    Tibial tubercle trochlear groove distance (TTD) is a significant factor in patello-femoral instability. Initially described on CT scans with the knee in full extension, the measurement has been validated on MR scans. Dedicated knee MRI coils have subsequently superseded both CT and MRI body coils for knee imaging. However, the knee rests in partial flexion within the dedicated knee coil. The objective of this study is to investigate whether images from dedicated knee MRI coils produce different TTD measurements from MR body coils. Thirty-two symptomatic knees (27 patients) had simultaneous knee MR scans performed in both a dedicated knee coil and a body coil. TTD measurements were independently compared to assess whether the coil type used affected TTD. Patients' ages ranged from 10 to 27 years (mean 15 years). Mean TTD in the dedicated knee coil (partially flexed knee) was 11.3 mm compared with 19.9 mm in the body coil (that permits full knee extension). The mean difference was 8.6 mm, which was highly significant (p < 0.0001, unpaired t test). Inter-rater correlation co-efficient was 96 %. Of the knees that recorded a ''normal'' TTD on the dedicated knee coil, 60-100 % recorded a ''pathological'' TTD on body coil images, depending on which diagnostic value for ''normal'' cut-off was used. This study has identified a highly significant difference in TTD measurement when knees are scanned in a dedicated knee coil with the knee partially flexed, compared with an MR body coil. It is critical for surgeons and radiologists managing patello-femoral instability to appreciate this profound difference. TTD measurement taken from knees scanned in dedicated knee coils may lead to patients being falsely re-assured or erroneously denied surgery. (orig.)

  10. Accessing doctors at times of need-measuring the distance tolerance of rural residents for health-related travel.

    Science.gov (United States)

    McGrail, Matthew Richard; Humphreys, John Stirling; Ward, Bernadette

    2015-05-29

    Poor access to doctors at times of need remains a significant impediment to achieving good health for many rural residents. The two-step floating catchment area (2SFCA) method has emerged as a key tool for measuring healthcare access in rural areas. However, the choice of catchment size, a key component of the 2SFCA method, is problematic because little is known about the distance tolerance of rural residents for health-related travel. Our study sought new evidence to test the hypothesis that residents of sparsely settled rural areas are prepared to travel further than residents of closely settled rural areas when accessing primary health care at times of need. A questionnaire survey of residents in five small rural communities of Victoria and New South Wales in Australia was used. The two outcome measures were current travel time to visit their usual doctor and maximum time prepared to travel to visit a doctor, both for non-emergency care. Kaplan-Meier charts were used to compare the association between increased distance and decreased travel propensity for closely-settled and sparsely-settled areas, and ordinal multivariate regression models tested significance after controlling for health-related travel moderating factors and town clustering. A total of 1079 questionnaires were completed with 363 from residents in closely-settled locations and 716 from residents in sparsely-settled areas. Residents of sparsely-settled communities travel, on average, 10 min further than residents of closely-settled communities (26.3 vs 16.9 min, p time prepared to travel (54.1 vs 31.9 min, p time remained significant after controlling for demographic and other constraints to access, such as transport availability or difficulties getting doctor appointments, as well as after controlling for town clustering and current travel times. Improved geographical access remains a key issue underpinning health policies designed to improve the provision of rural primary health care

  11. Demonstration of an efficient interpolation technique of inverse time and distance for Oceansat-2 wind measurements at 6-hourly intervals

    Directory of Open Access Journals (Sweden)

    J Swain

    2017-12-01

    Full Text Available Indian Space Research Organization had launched Oceansat-2 on 23 September 2009, and the scatterometer onboard was a space-borne sensor capable of providing ocean surface winds (both speed and direction over the globe for a mission life of 5 years. The observations of ocean surface winds from such a space-borne sensor are the potential source of data covering the global oceans and useful for driving the state-of-the-art numerical models for simulating ocean state if assimilated/blended with weather prediction model products. In this study, an efficient interpolation technique of inverse distance and time is demonstrated using the Oceansat-2 wind measurements alone for a selected month of June 2010 to generate gridded outputs. As the data are available only along the satellite tracks and there are obvious data gaps due to various other reasons, Oceansat-2 winds were subjected to spatio-temporal interpolation, and 6-hour global wind fields for the global oceans were generated over 1 × 1 degree grid resolution. Such interpolated wind fields can be used to drive the state-of-the-art numerical models to predict/hindcast ocean-state so as to experiment and test the utility/performance of satellite measurements alone in the absence of blended fields. The technique can be tested for other satellites, which provide wind speed as well as direction data. However, the accuracy of input winds is obviously expected to have a perceptible influence on the predicted ocean-state parameters. Here, some attempts are also made to compare the interpolated Oceansat-2 winds with available buoy measurements and it was found that they are reasonably in good agreement with a correlation coefficient of R  > 0.8 and mean deviation 1.04 m/s and 25° for wind speed and direction, respectively.

  12. DNA with Parallel Strand Orientation: A Nanometer Distance Study with Spin Labels in the Watson-Crick and the Reverse Watson-Crick Double Helix.

    Science.gov (United States)

    Wunnicke, Dorith; Ding, Ping; Yang, Haozhe; Seela, Frank; Steinhoff, Heinz-Jürgen

    2015-10-29

    Parallel-stranded (ps) DNA characterized by its sugar-phosphate backbones pointing in the same direction represents an alternative pairing system to antiparallel-stranded (aps) DNA with the potential to inhibit transcription and translation. 25-mer oligonucleotides were selected containing only dA·dT base pairs to compare spin-labeled nucleobase distances over a range of 10 or 15 base pairs in ps DNA with those in aps DNA. By means of the copper(I)-catalyzed Huisgen-Meldal-Sharpless alkyne-azide cycloaddition, the spin label 4-azido-2,2,6,6-tetramethylpiperidine-1-oxyl was clicked to 7-ethynyl-7-deaza-2'-deoxyadenosine or 5-ethynyl-2'-deoxyuridine to yield 25-mer oligonucleotides incorporating two spin labels. The interspin distances between spin labeled residues were determined by pulse EPR spectroscopy. The results reveal that in ps DNA these distances are between 5 and 10% longer than in aps DNA when the labeled DNA segment is located near the center of the double helix. The interspin distance in ps DNA becomes shorter compared with aps DNA when one of the spin labels occupies a position near the end of the double helix.

  13. Fast Computing for Distance Covariance

    OpenAIRE

    Huo, Xiaoming; Szekely, Gabor J.

    2014-01-01

    Distance covariance and distance correlation have been widely adopted in measuring dependence of a pair of random variables or random vectors. If the computation of distance covariance and distance correlation is implemented directly accordingly to its definition then its computational complexity is O($n^2$) which is a disadvantage compared to other faster methods. In this paper we show that the computation of distance covariance and distance correlation of real valued random variables can be...

  14. Recoil-distance lifetime measurements of the ground-state band in 164Dy, 170Er, and 174Yb

    International Nuclear Information System (INIS)

    Sie, S.H.; Gebbie, D.W.

    1977-06-01

    Mean-lives of the 4 + , 6 + and 8 + levels of the ground-state band in 164 Dy, 170 Er and 174 Yb have been measured by the recoil-distance technique following multiple Coulomb excitation with 32 S projectiles of energy 120-140 MeV. The gamma-rays were detected in coincidence with backscattered particles. The results are compared with theoretical predictions of the adiabatic rotor model. The 6 + and 8 + lifetimes in 164 Dy are found to correspond to a slight reduction in B(E2) values over the rotational model prediction, while for for the 4 + state a 12% reduction was observed. In 170 Er and 174 Yb the lifetimes are consistent with rotational model predictions with a slight enhancement of B(E2) values at higher spins. Comparison with other results from Doppler broadened lineshape analysis confirms the need to adjust the electronic stopping powers of Northcliffe and Schilling in the lineshape calculations. (Author)

  15. Note: Optical and electronic design of an amplitude-modulated continuous-wave laser scanner for high-accuracy distance measurement

    International Nuclear Information System (INIS)

    Jang, Junhwan; Hwang, Sungui; Park, Kyihwan

    2015-01-01

    To utilize a time-of-flight-based laser scanner as a distance measurement sensor, the measurable distance and accuracy are the most important performance parameters to consider. For these purposes, the optical system and electronic signal processing of the laser scanner should be optimally designed in order to reduce a distance error caused by the optical crosstalk and wide dynamic range input. Optical system design for removing optical crosstalk problem is proposed in this work. Intensity control is also considered to solve the problem of a phase-shift variation in the signal processing circuit caused by object reflectivity. The experimental results for optical system and signal processing design are performed using 3D measurements

  16. Note: Optical and electronic design of an amplitude-modulated continuous-wave laser scanner for high-accuracy distance measurement

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Junhwan; Hwang, Sungui; Park, Kyihwan, E-mail: khpark@gist.ac.kr [School of Mechatronics, Gwangju Institute of Science and Technology, 123 Cheomdangwagi-ro, Buk-gu, Gwangju (Korea, Republic of)

    2015-04-15

    To utilize a time-of-flight-based laser scanner as a distance measurement sensor, the measurable distance and accuracy are the most important performance parameters to consider. For these purposes, the optical system and electronic signal processing of the laser scanner should be optimally designed in order to reduce a distance error caused by the optical crosstalk and wide dynamic range input. Optical system design for removing optical crosstalk problem is proposed in this work. Intensity control is also considered to solve the problem of a phase-shift variation in the signal processing circuit caused by object reflectivity. The experimental results for optical system and signal processing design are performed using 3D measurements.

  17. Walking Behavior of Zoo Elephants: Associations between GPS-Measured Daily Walking Distances and Environmental Factors, Social Factors, and Welfare Indicators.

    Directory of Open Access Journals (Sweden)

    Matthew R Holdgate

    Full Text Available Research with humans and other animals suggests that walking benefits physical health. Perhaps because these links have been demonstrated in other species, it has been suggested that walking is important to elephant welfare, and that zoo elephant exhibits should be designed to allow for more walking. Our study is the first to address this suggestion empirically by measuring the mean daily walking distance of elephants in North American zoos, determining the factors that are associated with variations in walking distance, and testing for associations between walking and welfare indicators. We used anklets equipped with GPS data loggers to measure outdoor daily walking distance in 56 adult female African (n = 33 and Asian (n = 23 elephants housed in 30 North American zoos. We collected 259 days of data and determined associations between distance walked and social, housing, management, and demographic factors. Elephants walked an average of 5.3 km/day with no significant difference between species. In our multivariable model, more diverse feeding regimens were correlated with increased walking, and elephants who were fed on a temporally unpredictable feeding schedule walked 1.29 km/day more than elephants fed on a predictable schedule. Distance walked was also positively correlated with an increase in the number of social groupings and negatively correlated with age. We found a small but significant negative correlation between distance walked and nighttime Space Experience, but no other associations between walking distances and exhibit size were found. Finally, distance walked was not related to health or behavioral outcomes including foot health, joint health, body condition, and the performance of stereotypic behavior, suggesting that more research is necessary to determine explicitly how differences in walking may impact elephant welfare.

  18. Walking Behavior of Zoo Elephants: Associations between GPS-Measured Daily Walking Distances and Environmental Factors, Social Factors, and Welfare Indicators.

    Science.gov (United States)

    Holdgate, Matthew R; Meehan, Cheryl L; Hogan, Jennifer N; Miller, Lance J; Soltis, Joseph; Andrews, Jeff; Shepherdson, David J

    2016-01-01

    Research with humans and other animals suggests that walking benefits physical health. Perhaps because these links have been demonstrated in other species, it has been suggested that walking is important to elephant welfare, and that zoo elephant exhibits should be designed to allow for more walking. Our study is the first to address this suggestion empirically by measuring the mean daily walking distance of elephants in North American zoos, determining the factors that are associated with variations in walking distance, and testing for associations between walking and welfare indicators. We used anklets equipped with GPS data loggers to measure outdoor daily walking distance in 56 adult female African (n = 33) and Asian (n = 23) elephants housed in 30 North American zoos. We collected 259 days of data and determined associations between distance walked and social, housing, management, and demographic factors. Elephants walked an average of 5.3 km/day with no significant difference between species. In our multivariable model, more diverse feeding regimens were correlated with increased walking, and elephants who were fed on a temporally unpredictable feeding schedule walked 1.29 km/day more than elephants fed on a predictable schedule. Distance walked was also positively correlated with an increase in the number of social groupings and negatively correlated with age. We found a small but significant negative correlation between distance walked and nighttime Space Experience, but no other associations between walking distances and exhibit size were found. Finally, distance walked was not related to health or behavioral outcomes including foot health, joint health, body condition, and the performance of stereotypic behavior, suggesting that more research is necessary to determine explicitly how differences in walking may impact elephant welfare.

  19. Haptic Discrimination of Distance

    Science.gov (United States)

    van Beek, Femke E.; Bergmann Tiest, Wouter M.; Kappers, Astrid M. L.

    2014-01-01

    While quite some research has focussed on the accuracy of haptic perception of distance, information on the precision of haptic perception of distance is still scarce, particularly regarding distances perceived by making arm movements. In this study, eight conditions were measured to answer four main questions, which are: what is the influence of reference distance, movement axis, perceptual mode (active or passive) and stimulus type on the precision of this kind of distance perception? A discrimination experiment was performed with twelve participants. The participants were presented with two distances, using either a haptic device or a real stimulus. Participants compared the distances by moving their hand from a start to an end position. They were then asked to judge which of the distances was the longer, from which the discrimination threshold was determined for each participant and condition. The precision was influenced by reference distance. No effect of movement axis was found. The precision was higher for active than for passive movements and it was a bit lower for real stimuli than for rendered stimuli, but it was not affected by adding cutaneous information. Overall, the Weber fraction for the active perception of a distance of 25 or 35 cm was about 11% for all cardinal axes. The recorded position data suggest that participants, in order to be able to judge which distance was the longer, tried to produce similar speed profiles in both movements. This knowledge could be useful in the design of haptic devices. PMID:25116638

  20. Haptic discrimination of distance.

    Directory of Open Access Journals (Sweden)

    Femke E van Beek

    Full Text Available While quite some research has focussed on the accuracy of haptic perception of distance, information on the precision of haptic perception of distance is still scarce, particularly regarding distances perceived by making arm movements. In this study, eight conditions were measured to answer four main questions, which are: what is the influence of reference distance, movement axis, perceptual mode (active or passive and stimulus type on the precision of this kind of distance perception? A discrimination experiment was performed with twelve participants. The participants were presented with two distances, using either a haptic device or a real stimulus. Participants compared the distances by moving their hand from a start to an end position. They were then asked to judge which of the distances was the longer, from which the discrimination threshold was determined for each participant and condition. The precision was influenced by reference distance. No effect of movement axis was found. The precision was higher for active than for passive movements and it was a bit lower for real stimuli than for rendered stimuli, but it was not affected by adding cutaneous information. Overall, the Weber fraction for the active perception of a distance of 25 or 35 cm was about 11% for all cardinal axes. The recorded position data suggest that participants, in order to be able to judge which distance was the longer, tried to produce similar speed profiles in both movements. This knowledge could be useful in the design of haptic devices.

  1. modelling distances

    Directory of Open Access Journals (Sweden)

    Robert F. Love

    2001-01-01

    Full Text Available Distance predicting functions may be used in a variety of applications for estimating travel distances between points. To evaluate the accuracy of a distance predicting function and to determine its parameters, a goodness-of-fit criteria is employed. AD (Absolute Deviations, SD (Squared Deviations and NAD (Normalized Absolute Deviations are the three criteria that are mostly employed in practice. In the literature some assumptions have been made about the properties of each criterion. In this paper, we present statistical analyses performed to compare the three criteria from different perspectives. For this purpose, we employ the ℓkpθ-norm as the distance predicting function, and statistically compare the three criteria by using normalized absolute prediction error distributions in seventeen geographical regions. We find that there exist no significant differences between the criteria. However, since the criterion SD has desirable properties in terms of distance modelling procedures, we suggest its use in practice.

  2. Evaluation of Coflex interspinous stabilization following decompression compared with decompression and posterior lumbar interbody fusion for the treatment of lumbar degenerative disease: A minimum 5-year follow-up study.

    Science.gov (United States)

    Yuan, Wei; Su, Qing-Jun; Liu, Tie; Yang, Jin-Cai; Kang, Nan; Guan, Li; Hai, Yong

    2017-01-01

    Few studies have compared the clinical and radiological outcomes between Coflex interspinous stabilization and posterior lumbar interbody fusion (PLIF) for degenerative lumbar disease. We compared the at least 5-year clinical and radiological outcomes of Coflex stabilization and PLIF for lumbar degenerative disease. Eighty-seven consecutive patients with lumbar degenerative disease were retrospectively reviewed. Forty-two patients underwent decompression and Coflex interspinous stabilization (Coflex group), 45 patients underwent decompression and PLIF (PLIF group). Clinical and radiological outcomes were evaluated. Coflex subjects experienced less blood loss, shorter hospital stays and shorter operative time than PLIF (all pdisease was higher in the PLIF group, but this did not achieve statistical significance (11.1% vs. 4.8%, p=0.277). Both groups provided sustainable improved clinical outcomes for lumbar degenerative disease through at least 5-year follow-up. The Coflex group had significantly better early efficacy than the PLIF group. Coflex interspinous implantation after decompression is safe and effective for lumbar degenerative disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices

    Directory of Open Access Journals (Sweden)

    Alberto Domínguez-Vicent

    2014-08-01

    Full Text Available Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D. Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera and the Pentacam HR (single Scheimpflug camera systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured with the Galilei G4 and the Pentacam HR, respectively. The mean white-to-white distance measured was 11.84 ± 0.31 mm and 11.90 ± 0.43 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Mean pupil diameters were measured as 3.22 ± 0.58 mm and 3.22 ± 0.52 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Finally, the mean anterior chamber angle was 34.30 ± 2.86 degrees when it was measured with the Galilei G4, and 39.26 ± 2.85 degrees when measured with the Pentacam HR. A comparative analysis revealed that the Galilei G4 yielded a significantly lower (P0.05 for both devices were obtained for the white-to-white distance measurements. Conclusion: The Galilei G4 and Pentacam HR Scheimpflug systems cannot be used interchangeably because they produce significant measurement differences.

  4. The Hetu'u Global Network: Measuring the Distance to the Sun Using the June 5th/6th Transit of Venus

    Science.gov (United States)

    Faherty, Jacqueline K.; Rodriguez, David R.; Miller, Scott T.

    2012-01-01

    In the spirit of historic astronomical endeavors, we invited school groups across the globe to collaborate in a solar distance measurement using the rare June 5/6th transit of Venus. In total, we recruited 19 school groups spread over 6 continents and 10 countries to participate in our Hetu'u Global Network. Applying the methods of French…

  5. Technology Learning Activities. Design Brief--Measuring Inaccessible Distances. Alternative Energy Sources: Designing a Wind Powered Generator. Alternative Energy Sources: Designing a Hot Dog Heater Using Solar Energy.

    Science.gov (United States)

    Technology Teacher, 1991

    1991-01-01

    These three learning activities are on measuring accessible distances, designing a wind powered generator, and designing a hot dog heater using solar energy. Each activity includes description of context, objectives, list of materials and equipment, challenge to students, and evaluation questions. (SK)

  6. Association between light absorption measurements of PM2.5 and distance from heavy traffic roads in the Mexico City metropolitan area.

    Science.gov (United States)

    Cortez-Lugo, Marlene; Escamilla-Núñez, Consuelo; Barraza-Villarreal, Albino; Texcalac-Sangrador, José Luis; Chow, Judith; Watson, John; Hernández-Cadena, Leticia; Romieu, Isabelle

    2013-04-01

    To study the relationship between light absorption measurements of PM2.5 at various distances from heavy traffic roads and diesel vehicle counts in Mexico City. PM2.5 samples were obtained from June 2003-June 2005 in three MCMA regions. Light absorption (b abs) in a subset of PM2.5 samples was determined. We evaluated the effect of distance and diesel vehicle counts to heavy traffic roads on PM2.5 b abs using generalized estimating equation models. Median PM2.5 b abs measurements significantly decrease as distance from heavy traffic roads increases (proads. Our model predicts that PM2.5 b abs measurements would increase by 20% (CI95% 3-38) as the hourly heavy diesel vehicle count increases by 150 per hour. PM2.5 b abs measurements are significantly associated with distance from motorways and traffic density and therefore can be used to assess human exposure to traffic-related emissions.

  7. Optical method for distance and displacement measurements of the probe-sample separation in a scanning near-field optical microscope

    International Nuclear Information System (INIS)

    Santamaria, L.; Siller, H. R.; Garcia-Ortiz, C. E.; Cortes, R.; Coello, V.

    2016-01-01

    In this work, we present an alternative optical method to determine the probe-sample separation distance in a scanning near-field optical microscope. The experimental method is based in a Lloyd’s mirror interferometer and offers a measurement precision deviation of ∼100 nm using digital image processing and numerical analysis. The technique can also be strategically combined with the characterization of piezoelectric actuators and stability evaluation of the optical system. It also opens the possibility for the development of an automatic approximation control system valid for probe-sample distances from 5 to 500 μm.

  8. Optical method for distance and displacement measurements of the probe-sample separation in a scanning near-field optical microscope

    Energy Technology Data Exchange (ETDEWEB)

    Santamaria, L.; Siller, H. R. [Tecnológico de Monterrey, Eugenio Garza Sada 2501 Sur, Monterrey, N.L., 64849 (Mexico); Garcia-Ortiz, C. E., E-mail: cegarcia@cicese.mx [CONACYT Research Fellow – CICESE, Unidad Monterrey, Alianza Centro 504, Apodaca, NL, 66629 (Mexico); Cortes, R.; Coello, V. [CICESE, Unidad Monterrey, PIIT, Alianza Centro 504, Apodaca, NL, 66629 (Mexico)

    2016-04-15

    In this work, we present an alternative optical method to determine the probe-sample separation distance in a scanning near-field optical microscope. The experimental method is based in a Lloyd’s mirror interferometer and offers a measurement precision deviation of ∼100 nm using digital image processing and numerical analysis. The technique can also be strategically combined with the characterization of piezoelectric actuators and stability evaluation of the optical system. It also opens the possibility for the development of an automatic approximation control system valid for probe-sample distances from 5 to 500 μm.

  9. Phase-coded microwave signal generation based on a single electro-optical modulator and its application in accurate distance measurement.

    Science.gov (United States)

    Zhang, Fangzheng; Ge, Xiaozhong; Gao, Bindong; Pan, Shilong

    2015-08-24

    A novel scheme for photonic generation of a phase-coded microwave signal is proposed and its application in one-dimension distance measurement is demonstrated. The proposed signal generator has a simple and compact structure based on a single dual-polarization modulator. Besides, the generated phase-coded signal is stable and free from the DC and low-frequency backgrounds. An experiment is carried out. A 2 Gb/s phase-coded signal at 20 GHz is successfully generated, and the recovered phase information agrees well with the input 13-bit Barker code. To further investigate the performance of the proposed signal generator, its application in one-dimension distance measurement is demonstrated. The measurement accuracy is less than 1.7 centimeters within a measurement range of ~2 meters. The experimental results can verify the feasibility of the proposed phase-coded microwave signal generator and also provide strong evidence to support its practical applications.

  10. Long-distance Dispersal Patterns of Male Cerulean Warblers (Dendroica cerulea Measured by Stable-hydrogen Isotopes

    Directory of Open Access Journals (Sweden)

    M. Katherine. Girvan

    2007-12-01

    Full Text Available Despite the fundamental role played by long-distance dispersal in population dynamics, the mechanisms promoting or inhibiting dispersal by migratory songbirds are poorly understood. We used stable-hydrogen isotopes (δD to evaluate several hypotheses related to long-distance dispersal in the Cerulean Warbler (Dendroica cerulea, a migratory songbird at the center of considerable conservation attention. Feather samples were collected from 103 males throughout the breeding range. We assumed feathers were molted in late summer on the breeding grounds and thus δD values provided an estimate of breeding or hatching location for the previous year. We used a likelihood-based assignment test to estimate the origin of birds the previous year and derived expected δD values for the entire Cerulean Warbler breeding range from precipitation-based maps. Using Bayes' Rule, we also incorporated a prior probability of breeding origin based on estimated rates of site fidelity and survival between breeding seasons. We found that long-distance breeding dispersal by adult male Cerulean Warblers was a fairly common occurrence with 20 of 71 (28.2% individuals originating from a region other than the one they were sampled in. Surprisingly, long-distance natal dispersal was uncommon; only three of 32 (9.4% second-year birds were estimated to have hatched in a region outside their capture region. Young males may be using a form of post-fledging prospecting or conspecific attraction when selecting their first breeding habitats. Populations on the breeding range periphery, such as Ontario and Tennessee, tended to receive fewer long-distance dispersers than did other regions but produced more dispersing individuals than did core regions, suggesting that these areas could act as important sources for other regions. The tendency of a region to produce dispersing individuals was not significantly related to its relative abundance, implying that population abundance is not a

  11. The Next Generation Virgo Cluster Survey (NGVS). XVIII. Measurement and Calibration of Surface Brightness Fluctuation Distances for Bright Galaxies in Virgo (and Beyond)

    Science.gov (United States)

    Cantiello, Michele; Blakeslee, John P.; Ferrarese, Laura; Côté, Patrick; Roediger, Joel C.; Raimondo, Gabriella; Peng, Eric W.; Gwyn, Stephen; Durrell, Patrick R.; Cuillandre, Jean-Charles

    2018-04-01

    We describe a program to measure surface brightness fluctuation (SBF) distances to galaxies observed in the Next Generation Virgo Cluster Survey (NGVS), a photometric imaging survey covering 104 deg2 of the Virgo cluster in the u*, g, i, and z bandpasses with the Canada–France–Hawaii Telescope. We describe the selection of the sample galaxies, the procedures for measuring the apparent i-band SBF magnitude {\\overline{m}}i, and the calibration of the absolute Mibar as a function of observed stellar population properties. The multiband NGVS data set provides multiple options for calibrating the SBF distances, and we explore various calibrations involving individual color indices as well as combinations of two different colors. Within the color range of the present sample, the two-color calibrations do not significantly improve the scatter with respect to wide-baseline, single-color calibrations involving u*. We adopt the ({u}* -z) calibration as a reference for the present galaxy sample, with an observed scatter of 0.11 mag. For a few cases that lack good u* photometry, we use an alternative relation based on a combination of (g-i) and (g-z) colors, with only a slightly larger observed scatter of 0.12 mag. The agreement of our measurements with the best existing distance estimates provides confidence that our measurements are accurate. We present a preliminary catalog of distances for 89 galaxies brighter than B T ≈ 13.0 mag within the survey footprint, including members of the background M and W Clouds at roughly twice the distance of the main body of the Virgo cluster. The extension of the present work to fainter and bluer galaxies is in progress.

  12. Verification of two simple meteorological models at large travel distances using ten-hour 85Kr measurements

    International Nuclear Information System (INIS)

    Pendergast, M.M.

    1978-01-01

    This report evaluates the wind-rose model and a trajectory model for calculating air concentrations averaged over 10 hours at distances greater than 100 km. Ten-hour averaged 85 Kr air concentrations from 13 sites located withing 143 km of the Savannah River Plant (SRP) were used to evaluate two simple models: a wind-rose model, and a trajectory model. The wind-rose model has previously been shown to estimate annual average concentrations to within a factor of four for travel distances of about 100 km. When 85 Kr concentrations were observed (80 cases), the wind-rose model predicted above background for only 36 percent of the cases, while the trajectory model predicted above background for 56 percent of the cases. The wind-rose model tended to overpredict air concentration by a factor of 4 while the trajectory model tended to underpredict by a factor of 3 for those occasions where observations and calculations were above background

  13. A biomechanical comparison of the Rogers interspinous and the Lovely-Carl tension band wiring techniques for fixation of the cervical spine.

    Science.gov (United States)

    Brasil, A V; Coehlo, D G; Filho, T E; Braga, F M

    2000-07-01

    The authors conducted a biomechanical study in which they compared the uses of the Rogers interspinous and the Lovely-Carl tension band wiring techniques for internal fixation of the cervical spine. An extensive biomechanical evaluation (stiffness in positive and negative rotations around the x, y, and z axes; range of motion in flexion-extension, bilateral axial rotation, and bilateral bending; and neutral zone in flexion-extension, bilateral axial rotation, and lateral bending to the right and to the left) was performed in two groups of intact calf cervical spines. After these initial tests, all specimens were subjected to a distractive flexion Stage 3 ligamentous lesion. Group 1 specimens then underwent surgical fixation by the Rogers technique, and Group 2 specimens underwent surgery by using the Lovely-Carl technique. After fixation, specimens were again submitted to the same biomechanical evaluation. The percentage increase or decrease between the pre- and postoperative parameters was calculated. These values were considered quantitative indicators of the efficacy of the techniques, and the efficacy of the two techniques was compared. Analysis of the findings demonstrated that in the spines treated with the Lovely-Carl technique less restriction of movement was produced without affecting stiffness, compared with those treated with the Rogers technique, thus making the Lovely-Carl technique clinically less useful.

  14. Extending multivariate distance matrix regression with an effect size measure and the asymptotic null distribution of the test statistic.

    Science.gov (United States)

    McArtor, Daniel B; Lubke, Gitta H; Bergeman, C S

    2017-12-01

    Person-centered methods are useful for studying individual differences in terms of (dis)similarities between response profiles on multivariate outcomes. Multivariate distance matrix regression (MDMR) tests the significance of associations of response profile (dis)similarities and a set of predictors using permutation tests. This paper extends MDMR by deriving and empirically validating the asymptotic null distribution of its test statistic, and by proposing an effect size for individual outcome variables, which is shown to recover true associations. These extensions alleviate the computational burden of permutation tests currently used in MDMR and render more informative results, thus making MDMR accessible to new research domains.

  15. Computed Tomography Based Three-dimensional Measurements of Spine Shortening Distance After Posterior Three-column Osteotomies for the Treatment of Severe and Stiff Scoliosis.

    Science.gov (United States)

    Li, Xue-Shi; Huang, Zi-Fang; Deng, Yao-Long; Fan, Heng-Wei; Sui, Wen-Yuan; Wang, Chong-Wen; Yang, Jun-Lin

    2017-07-15

    Retrospective study. This study is to measure and analyze the changes of three-dimensional (3D) distances of spinal column and spinal canal at the three-column osteotomy sites and address their clinical and neurologic significance. Three-column osteotomies were developed to treat severe and stiff spine deformities with insufficient understanding on the safe limit of spine shortening and the relationship between the shortening distance of the spinal column and that of the spinal canal. Records of 52 continuous patients with severe and stiff scoliosis treated with three-column spine osteotomies at our institution from July 2013 to June 2015 were reviewed. The preoperative spinal cord function classification were type A in 31 cases, type B in 10 cases, and type C in 11 cases. The types of osteotomies carried out were extended pedicle subtraction osteotomy in nine patients and posterior vertebral column resection in 43 patients. Multimodality neuromonitoring strategies were adopted intraoperatively. 3D pre- and postoperative spine models were reconstructed from the computed tomography (CT) scans. The distances of convex and concave spinal column and the spinal canal shortening were measured and analyzed. The spinal column shortening distance (SCSD) measured on the 3D models (27.8 mm) were statistically shorter than those measured intraoperatively (32.8 mm) (P column strut graft than in those with bone-on-bone fusion (P column cannot represent that of the central spinal canal in patients with severe scoliosis. The spinal column shortening procedure in appropriately selected patient groups with bone-on-bone fusion is a viable option with the CCSD being significantly shorter than the convex SCSD. 4.

  16. Distance learning

    Directory of Open Access Journals (Sweden)

    Katarina Pucelj

    2006-12-01

    Full Text Available I would like to underline the role and importance of knowledge, which is acquired by individuals as a result of a learning process and experience. I have established that a form of learning, such as distance learning definitely contributes to a higher learning quality and leads to innovative, dynamic and knowledgebased society. Knowledge and skills enable individuals to cope with and manage changes, solve problems and also create new knowledge. Traditional learning practices face new circumstances, new and modern technologies appear, which enable quick and quality-oriented knowledge implementation. The centre of learning process at distance learning is to increase the quality of life of citizens, their competitiveness on the workforce market and ensure higher economic growth. Intellectual capital is the one, which represents the biggest capital of each society and knowledge is the key factor for succes of everybody, who are fully aware of this. Flexibility, openness and willingness of people to follow new IT solutions form suitable environment for developing and deciding to take up distance learning.

  17. A comparison of 3-D computed tomography versus 2-D radiography measurements of ulnar variance and ulnolunate distance during forearm rotation.

    Science.gov (United States)

    Kawanishi, Y; Moritomo, H; Omori, S; Kataoka, T; Murase, T; Sugamoto, K

    2014-06-01

    Positive ulnar variance is associated with ulnar impaction syndrome and ulnar variance is reported to increase with pronation. However, radiographic measurement can be affected markedly by the incident angle of the X-ray beam. We performed three-dimensional (3-D) computed tomography measurements of ulnar variance and ulnolunate distance during forearm rotation and compared these with plain radiographic measurements in 15 healthy wrists. From supination to pronation, ulnar variance increased in all cases on the radiographs; mean ulnar variance increased significantly and mean ulnolunate distance decreased significantly. However on 3-D imaging, ulna variance decreased in 12 cases on moving into pronation and increased in three cases; neither the mean ulnar variance nor mean ulnolunate distance changed significantly. Our results suggest that the forearm position in which ulnar variance increased varies among individuals. This may explain why some patients with ulnar impaction syndrome complain of wrist pain exacerbated by forearm supination. It also suggests that standard radiographic assessments of ulnar variance are unreliable. © The Author(s) 2013.

  18. Recoil-distance lifetime measurements in 96,97,98Ru: Search for possible onset of collectivity at N≥52

    International Nuclear Information System (INIS)

    Kharraja, B.; Garg, U.; Ghugre, S. S.; Jin, H.; Janssens, R. V. F.; Ahmad, I.; Amro, H.; Carpenter, M. P.; Fischer, S.; Khoo, T. L.

    2000-01-01

    Lifetimes of high-spin states in the N=52-54 Ru nuclei have been investigated via the 65 Cu( 36 S,pyn) 96,97,98 Ru (y=4,3,2) reactions using the recoil-distance Doppler-shift technique. The data were collected in coincidence mode. Lifetimes have been extracted for both the positive- and the negative-parity states in 96 Ru and 98 Ru and for the positive-parity states in 97 Ru. The levels studied have lifetimes in the range 2-31 ps. The observed reduced transition probabilities B(E2) and B(M1) are compared with the predictions of the shell model. Theoretical implications of these results are discussed. (c) 1999 The American Physical Society

  19. Distance covariance for stochastic processes

    DEFF Research Database (Denmark)

    Matsui, Muneya; Mikosch, Thomas Valentin; Samorodnitsky, Gennady

    2017-01-01

    The distance covariance of two random vectors is a measure of their dependence. The empirical distance covariance and correlation can be used as statistical tools for testing whether two random vectors are independent. We propose an analog of the distance covariance for two stochastic processes...

  20. An assessment method of dose equivalent due to indoor 220Rn progeny by using 220Rn concentration measured at a 20 cm distance from wall

    International Nuclear Information System (INIS)

    Iida, T.; Ikebe, Y.; Okamoto, K.; Guo, Q.; Yamasaki, T.

    1996-01-01

    A pair of passive cup monitors with a different air exchange openings was developed for measuring simultaneously 222 Rn and 220 Rn concentrations. Indoor 220 Rn concentrations were very high in traditional Japanese dwellings with soil walls. The 220 Rn concentration decreases exponentially with the distance from wall. The effective diffusion coefficient of 220 Rn in dwelling and the exhalation rate of 220 Rn from wall were evaluated from the distribution of the 220 Rn concentrations. Then, indoor 220 Rn progeny concentration could be estimated from the 220 Rn concentration at a 20 cm distance from wall. From the results of the surveys. the average annual effective dose equivalent due to 220 Rn progeny was expected to be 0.67 mSv/year in the traditional Japanese dwellings. (author)

  1. New measurements of distances to spirals in the great attractor - Further confirmation of the large-scale flow

    International Nuclear Information System (INIS)

    Dressler, A.; Faber, S.M.

    1990-01-01

    H-alpha rotation curves and CCD photometry have been obtained for 117 Sb-Sc spiral galaxies in the direction of the large-scale streaming flow. By means of the Tully-Fisher relation, these data are used to predict distances to these galaxies and, by comparison with their observed radial velocities, their peculiar motions relative to a smooth Hubble flow. The new data confirm the results of the earlier studies of a coherent flow pattern in a large region called the 'great attractor'. For the first time, evidence is found for backside infall into the great attractor. Taken as a whole, the data sets for E, S0, and spiral galaxies support the model proposed by Lynden-Bell et al. (1988) of a large, extended overdensity centered at about 45/h Mpc that perturbs the Hubble flow over a region less than about 100/h Mpc in diameter. Observation of the full 's-wave' in the Hubble flow establishes this scale for the structure, providing a strong constraint for models of structure formation, like those based on hot or cold dark matter. 24 refs

  2. DISTANCES TO DARK CLOUDS: COMPARING EXTINCTION DISTANCES TO MASER PARALLAX DISTANCES

    International Nuclear Information System (INIS)

    Foster, Jonathan B.; Jackson, James M.; Stead, Joseph J.; Hoare, Melvin G.; Benjamin, Robert A.

    2012-01-01

    We test two different methods of using near-infrared extinction to estimate distances to dark clouds in the first quadrant of the Galaxy using large near-infrared (Two Micron All Sky Survey and UKIRT Infrared Deep Sky Survey) surveys. Very long baseline interferometry parallax measurements of masers around massive young stars provide the most direct and bias-free measurement of the distance to these dark clouds. We compare the extinction distance estimates to these maser parallax distances. We also compare these distances to kinematic distances, including recent re-calibrations of the Galactic rotation curve. The extinction distance methods agree with the maser parallax distances (within the errors) between 66% and 100% of the time (depending on method and input survey) and between 85% and 100% of the time outside of the crowded Galactic center. Although the sample size is small, extinction distance methods reproduce maser parallax distances better than kinematic distances; furthermore, extinction distance methods do not suffer from the kinematic distance ambiguity. This validation gives us confidence that these extinction methods may be extended to additional dark clouds where maser parallaxes are not available.

  3. Monitoring kinetic and frequency-domain properties of eyelid responses in mice with magnetic distance measurement technique

    NARCIS (Netherlands)

    W.L. den Ouden; G. Perry; S.M. Highstein; C.I. de Zeeuw (Chris); S.K.E. Koekkoek (Bas)

    2002-01-01

    textabstractClassical eye-blink conditioning in mutant mice can be used to study the molecular mechanisms underlying associative learning. To measure the kinetic and frequency domain properties of conditioned (tone - periorbital shock procedure) and unconditioned eyelid responses

  4. Radiometric Normalization of Temporal Images Combining Automatic Detection of Pseudo-Invariant Features from the Distance and Similarity Spectral Measures, Density Scatterplot Analysis, and Robust Regression

    Directory of Open Access Journals (Sweden)

    Ana Paula Ferreira de Carvalho

    2013-05-01

    Full Text Available Radiometric precision is difficult to maintain in orbital images due to several factors (atmospheric conditions, Earth-sun distance, detector calibration, illumination, and viewing angles. These unwanted effects must be removed for radiometric consistency among temporal images, leaving only land-leaving radiances, for optimum change detection. A variety of relative radiometric correction techniques were developed for the correction or rectification of images, of the same area, through use of reference targets whose reflectance do not change significantly with time, i.e., pseudo-invariant features (PIFs. This paper proposes a new technique for radiometric normalization, which uses three sequential methods for an accurate PIFs selection: spectral measures of temporal data (spectral distance and similarity, density scatter plot analysis (ridge method, and robust regression. The spectral measures used are the spectral angle (Spectral Angle Mapper, SAM, spectral correlation (Spectral Correlation Mapper, SCM, and Euclidean distance. The spectral measures between the spectra at times t1 and t2 and are calculated for each pixel. After classification using threshold values, it is possible to define points with the same spectral behavior, including PIFs. The distance and similarity measures are complementary and can be calculated together. The ridge method uses a density plot generated from images acquired on different dates for the selection of PIFs. In a density plot, the invariant pixels, together, form a high-density ridge, while variant pixels (clouds and land cover changes are spread, having low density, facilitating its exclusion. Finally, the selected PIFs are subjected to a robust regression (M-estimate between pairs of temporal bands for the detection and elimination of outliers, and to obtain the optimal linear equation for a given set of target points. The robust regression is insensitive to outliers, i.e., observation that appears to deviate

  5. Long-distance mountain biking does not disturb the measurement of total, free or complexed prostate-specific antigen in healthy men.

    Science.gov (United States)

    Herrmann, Markus; Scharhag, Jürgen; Sand-Hill, Marga; Kindermann, Wilfried; Herrmann, Wolfgang

    2004-03-01

    Mechanical manipulation of the prostate is a generally accepted interfering factor for the measurement of prostate-specific antigen (PSA). However, only few studies have focused on common daily mechanical manipulations, such as bicycle riding. Furthermore, physical exercise is also supposed to modulate PSA serum concentration. Long-distance mountain biking is an excellent model to study the combined effect of mechanical prostate manipulation by bicycle riding and strenuous endurance exercise on total, free and complexed PSA (tPSA, fPSA, cPSA). We investigated tPSA, fPSA and cPSA in 42 healthy male cyclists (mean age 35+/-6 years) before and after a 120 km off-road mountain bike race. Blood sampling was done before, 15 min and 3 h after the race. Mean race time was 342+/-65 min. All athletes had normal serum levels of tPSA, fPSA or cPSA. None of these parameters was modified by the race. In healthy men the measurement of tPSA, fPSA and cPSA is not disturbed by preceding long distance mountain biking or endurance exercise. Based on the present data, there is no evidence for a recommendation to limit bicycle riding or physical activity before the measurement of tPSA, fPSA or cPSA.

  6. I Agree to Sit Next to You. Does That Mean I Like You? Measuring Using the Wrong Tapeline--The Lack of 'Social Distance' Measures for Inclusive School Development and Research--A Review of the Literature

    Science.gov (United States)

    Gerullis, Anita; Huber, Christian

    2018-01-01

    This review provides an overview of definitions and measurements of 'Social Distance' and attitudes children without disabilities carry towards children with disabilities. Measures include explicit and implicit approaches but clearly, the 'Bogardus Social Distance Scale' ("A Social Distance Scale," 1933, 14 May 2014) is the most used…

  7. The Cu2+-nitrilotriacetic acid complex improves loading of α-helical double histidine site for precise distance measurements by pulsed ESR

    Science.gov (United States)

    Ghosh, Shreya; Lawless, Matthew J.; Rule, Gordon S.; Saxena, Sunil

    2018-01-01

    Site-directed spin labeling using two strategically placed natural histidine residues allows for the rigid attachment of paramagnetic Cu2+. This double histidine (dHis) motif enables extremely precise, narrow distance distributions resolved by Cu2+-based pulsed ESR. Furthermore, the distance measurements are easily relatable to the protein backbone-structure. The Cu2+ ion has, till now, been introduced as a complex with the chelating agent iminodiacetic acid (IDA) to prevent unspecific binding. Recently, this method was found to have two limiting concerns that include poor selectivity towards α-helices and incomplete Cu2+-IDA complexation. Herein, we introduce an alternative method of dHis-Cu2+ loading using the nitrilotriacetic acid (NTA)-Cu2+ complex. We find that the Cu2+-NTA complex shows a four-fold increase in selectivity toward α-helical dHis sites. Furthermore, we show that 100% Cu2+-NTA complexation is achievable, enabling precise dHis loading and resulting in no free Cu2+ in solution. We analyze the optimum dHis loading conditions using both continuous wave and pulsed ESR. We implement these findings to show increased sensitivity of the Double Electron-Electron Resonance (DEER) experiment in two different protein systems. The DEER signal is increased within the immunoglobulin binding domain of protein G (called GB1). We measure distances between a dHis site on an α-helix and dHis site either on a mid-strand or a non-hydrogen bonded edge-strand β-sheet. Finally, the DEER signal is increased twofold within two α-helix dHis sites in the enzymatic dimer glutathione S-transferase exemplifying the enhanced α-helical selectivity of Cu2+-NTA.

  8. Measurement of vortex velocities over a wide range of vortex age, downstream distance and free stream velocity

    Science.gov (United States)

    Rorke, J. B.; Moffett, R. C.

    1977-01-01

    A wind tunnel test was conducted to obtain vortex velocity signatures over a wide parameter range encompassing the data conditions of several previous researchers while maintaining a common instrumentation and test facility. The generating wing panel was configured with both a revolved airfoil tip shape and a square tip shape and had a semispan aspect of 4.05/1.0 with a 121.9 cm span. Free stream velocity was varied from 6.1 m/sec to 76.2 m/sec and the vortex core velocities were measured at locations 3, 6, 12, 24 and 48 chordlengths downstream of the wing trailing edge, yielding vortex ages up to 2.0 seconds. Wing pitch angles of 6, 8, 9 and 12 deg were investigated. Detailed surface pressure distributions and wing force measurements were obtained for each wing tip configuration. Correlation with vortex velocity data taken in previous experiments is good. During the rollup process, vortex core parameters appear to be dependent primarily on vortex age. Trending in the plateau and decay regions is more complex and the machanisms appear to be more unstable.

  9. A new reliability measure based on specified minimum distances before the locations of random variables in a finite interval

    International Nuclear Information System (INIS)

    Todinov, M.T.

    2004-01-01

    A new reliability measure is proposed and equations are derived which determine the probability of existence of a specified set of minimum gaps between random variables following a homogeneous Poisson process in a finite interval. Using the derived equations, a method is proposed for specifying the upper bound of the random variables' number density which guarantees that the probability of clustering of two or more random variables in a finite interval remains below a maximum acceptable level. It is demonstrated that even for moderate number densities the probability of clustering is substantial and should not be neglected in reliability calculations. In the important special case where the random variables are failure times, models have been proposed for determining the upper bound of the hazard rate which guarantees a set of minimum failure-free operating intervals before the random failures, with a specified probability. A model has also been proposed for determining the upper bound of the hazard rate which guarantees a minimum availability target. Using the models proposed, a new strategy, models and reliability tools have been developed for setting quantitative reliability requirements which consist of determining the intersection of the hazard rate envelopes (hazard rate upper bounds) which deliver a minimum failure-free operating period before random failures, a risk of premature failure below a maximum acceptable level and a minimum required availability. It is demonstrated that setting reliability requirements solely based on an availability target does not necessarily mean a low risk of premature failure. Even at a high availability level, the probability of premature failure can be substantial. For industries characterised by a high cost of failure, the reliability requirements should involve a hazard rate envelope limiting the risk of failure below a maximum acceptable level

  10. Reproducibility of joint space width and the intermargin distance measurements in patients with medial osteoarthritis of the knee in various degrees of flexion

    International Nuclear Information System (INIS)

    Takahashi, Toshiaki; Yamamoto, Haruyasu; Yamanaka, Norio; Ikeuchi, Masahiko

    2009-01-01

    This study tested the variability and reproducibility of measurements of the joint space width (JSW) and intermargin distance (IMD) of the medial tibial plateau in specific positions of knee flexion in osteoarthritic knees in order to evaluate the most useful knee angle for radiographic measurements. Radiographs from 56 knees with osteoarthritis from 46 patients were taken with the knees in conventional full extension and 15 , 30 , and 45 of flexion with weight bearing. Three orthopedic surgeons independently measured the JSW and IMD at the narrowest point and the midpoint of medial tibial plateau using a computer-assisted method. The JSW and IMD were smallest at 15 flexion, both measured at the narrowest point and the midpoint of the medial compartment. Reproducibility of the IMD at the midpoint was better than at the narrowest point for all four flexion angles. Measurements of the medial JSW and IMD are smallest at 15 of knee flexion indicating that radiographs should be obtained at this angle in order to best demonstrate the extent of osteoarthritis. (orig.)

  11. Reproducibility of joint space width and the intermargin distance measurements in patients with medial osteoarthritis of the knee in various degrees of flexion

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Toshiaki; Yamamoto, Haruyasu [Ehime University Graduate School of Medicine, Department of Bone and Joint Surgery, Toon, Ehime (Japan); Yamanaka, Norio; Ikeuchi, Masahiko [Kochi University, Department of Orthopaedics, Kochi Medical School, Nankoku, Kochi (Japan)

    2009-01-15

    This study tested the variability and reproducibility of measurements of the joint space width (JSW) and intermargin distance (IMD) of the medial tibial plateau in specific positions of knee flexion in osteoarthritic knees in order to evaluate the most useful knee angle for radiographic measurements. Radiographs from 56 knees with osteoarthritis from 46 patients were taken with the knees in conventional full extension and 15 , 30 , and 45 of flexion with weight bearing. Three orthopedic surgeons independently measured the JSW and IMD at the narrowest point and the midpoint of medial tibial plateau using a computer-assisted method. The JSW and IMD were smallest at 15 flexion, both measured at the narrowest point and the midpoint of the medial compartment. Reproducibility of the IMD at the midpoint was better than at the narrowest point for all four flexion angles. Measurements of the medial JSW and IMD are smallest at 15 of knee flexion indicating that radiographs should be obtained at this angle in order to best demonstrate the extent of osteoarthritis. (orig.)

  12. Inter-Dye Distance Distributions Studied by a Combination of Single-Molecule FRET-Filtered Lifetime Measurements and a Weighted Accessible Volume (wAV Algorithm

    Directory of Open Access Journals (Sweden)

    Henning Höfig

    2014-11-01

    Full Text Available Förster resonance energy transfer (FRET is an important tool for studying the structural and dynamical properties of biomolecules. The fact that both the internal dynamics of the biomolecule and the movements of the biomolecule-attached dyes can occur on similar timescales of nanoseconds is an inherent problem in FRET studies. By performing single-molecule FRET-filtered lifetime measurements, we are able to characterize the amplitude of the motions of fluorescent probes attached to double-stranded DNA standards by means of flexible linkers. With respect to previously proposed experimental approaches, we improved the precision and the accuracy of the inter-dye distance distribution parameters by filtering out the donor-only population with pulsed interleaved excitation. A coarse-grained model is employed to reproduce the experimentally determined inter-dye distance distributions. This approach can easily be extended to intrinsically flexible proteins allowing, under certain conditions, to decouple the macromolecule amplitude of motions from the contribution of the dye linkers.

  13. The source-skin distance measuring bridge: A method to avoid radiation teleangiectasia in the skin after interstitial therapy for breast cancer

    International Nuclear Information System (INIS)

    Van Limbergen, E.; Briot, E.; Drijkoningen, M.

    1990-01-01

    Inappropriate positioning of interstitial iridium 192 implants, used as booster dose in the breast conserving treatment of mammary cancer, may cause disturbing teleangiectasia of the breast skin, when high radiation doses are delivered on the dermal blood vessels. Based on the localization of the vascular plexuses in human breast skin, and on the dose distribution around different types of interstitial implants, a method is described to avoid overlap between the high dose area of the implant and the blood vessels in the skin. The latter are demonstrated to run within the first 5 mm under the epiderm. For source lengths varying from 5 to 8 cm, simple mathematical relations exist between the maximal security margin (MSM) and intersource distance (E) for single plane implants (MSM = 0.4 (E + 1)), double plane square implants (MSM = 0.4 E) and double plane triangular implants (MSM = 0.4 (E - 1)). We developed a device to measure precisely the distance between the radioactive wires and the overlying skin, along the whole source trajectory. Using this method, the occurrence of teleangiectasia in the breast skin after interstitial implants with Ir 192 may be significantly reduced

  14. Deriving the radial distances of wide coronal mass ejections from elongation measurements in the heliosphere – application to CME-CME interaction

    Directory of Open Access Journals (Sweden)

    I. I. Roussev

    2009-09-01

    Full Text Available We present general considerations regarding the derivation of the radial distances of coronal mass ejections (CMEs from elongation angle measurements such as those provided by SECCHI and SMEI, focusing on measurements in the Heliospheric Imager 2 (HI-2 field of view (i.e. past 0.3 AU. This study is based on a three-dimensional (3-D magneto-hydrodynamics (MHD simulation of two CMEs observed by SECCHI on 24–27 January 2007. Having a 3-D simulation with synthetic HI images, we are able to compare the two basic methods used to derive CME positions from elongation angles, the so-called "Point-P" and "Fixed-φ" approximations. We confirm, following similar works, that both methods, while valid in the most inner heliosphere, yield increasingly large errors in HI-2 field of view for fast and wide CMEs. Using a simple model of a CME as an expanding self-similar sphere, we derive an analytical relationship between elongation angles and radial distances for wide CMEs. This relationship is simply the harmonic mean of the "Point-P" and "Fixed-φ" approximations and it is aimed at complementing 3-D fitting of CMEs by cone models or flux rope shapes. It proves better at getting the kinematics of the simulated CME right when we compare the results of our line-of-sights to the MHD simulation. Based on this approximation, we re-analyze the J-maps (time-elongation maps in 26–27 January 2007 and present the first observational evidence that the merging of CMEs is associated with a momentum exchange from the faster ejection to the slower one due to the propagation of the shock wave associated with the fast eruption through the slow eruption.

  15. Energy efficiency in the European Union: What can be learned from the joint application of directional distance functions and slacks-based measures?

    International Nuclear Information System (INIS)

    Gómez-Calvet, Roberto; Conesa, David; Gómez-Calvet, Ana Rosa; Tortosa-Ausina, Emili

    2014-01-01

    Highlights: • We analyze the efficiency of electricity and derived heat generation in the European Union (EU). • We consider both desirable and undesirable outputs. • In our specifications both directional distance functions and slacks-based measure models are used. • Results show remarkable efficiency differences among EU countries. • This would call for further intensification of harmonization environmental policies in the EU. - Abstract: Over the last few years concerns have increased about the energy mix in many countries. These concerns have been of greater magnitude for countries with a common energy regulation such as European Union (EU) member states. An important aspect to take into account when choosing a given energy mix is the efficiency involved in its generation. In this context, the present study analyzes the efficiency with which electricity and derived heat was produced in 25 EU member states over the last decade. This analysis considers not only the inputs and outputs involved but, more importantly, which undesirable by-products were generated during the production process, a relevant issue for EU climate policy. To this end, two nonparametric frontier models are applied: first, a Directional Distance Function (DDF), based on Briec’s (1997) [16] proposal and, second, a modified version of Tone’s (2001) [51] Slacks-Based Measure (SBM) model, both of which are especially appropriate in this particular context due to their treatment of undesirable outputs. Results are partly innovative since, with few exceptions, applications on this issue are relatively scarce. From a policy implications’ point of view, our achievements are also interesting because they reveal remarkable efficiency differences among EU countries: those countries from the latest EU enlargements account for the lowest efficiencies, with large opportunities for improvement in CO 2 abatement and primary energy saving. Results also show stable efficiencies along the

  16. Implementation and Comparison of Acoustic Travel-Time Measurement Procedures for the Solar Dynamics Observatory-Helioseismic and Magnetic Imager Time-Distance Helioseismology Pipeline

    Science.gov (United States)

    Couvidat, S.; Zhao, J.; Birch, A. C.; Kosovichev, A. G.; Duvall, Thomas L., Jr.; Parchevsky, K.; Scherrer, P. H.

    2010-01-01

    The Helioseismic and Magnetic Imager (HMI) instrument onboard the Solar Dynamics Observatory (SDO) satellite is designed to produce high-resolution Doppler-velocity maps of oscillations at the solar surface with high temporal cadence. To take advantage of these high-quality oscillation data, a time - distance helioseismology pipeline (Zhao et al., Solar Phys. submitted, 2010) has been implemented at the Joint Science Operations Center (JSOC) at Stanford University. The aim of this pipeline is to generate maps of acoustic travel times from oscillations on the solar surface, and to infer subsurface 3D flow velocities and sound-speed perturbations. The wave travel times are measured from cross-covariances of the observed solar oscillation signals. For implementation into the pipeline we have investigated three different travel-time definitions developed in time - distance helioseismology: a Gabor-wavelet fitting (Kosovichev and Duvall, SCORE'96: Solar Convection and Oscillations and Their Relationship, ASSL, Dordrecht, 241, 1997), a minimization relative to a reference cross-covariance function (Gizon and Birch, Astrophys. J. 571, 966, 2002), and a linearized version of the minimization method (Gizon and Birch, Astrophys. J. 614, 472, 2004). Using Doppler-velocity data from the Michelson Doppler Imager (MDI) instrument onboard SOHO, we tested and compared these definitions for the mean and difference traveltime perturbations measured from reciprocal signals. Although all three procedures return similar travel times in a quiet-Sun region, the method of Gizon and Birch (Astrophys. J. 614, 472, 2004) gives travel times that are significantly different from the others in a magnetic (active) region. Thus, for the pipeline implementation we chose the procedures of Kosovichev and Duvall (SCORE'96: Solar Convection and Oscillations and Their Relationship, ASSL, Dordrecht, 241, 1997) and Gizon and Birch (Astrophys. J. 571, 966, 2002). We investigated the relationships among

  17. Implementation and Comparison of Acoustic Travel-Time Measurement Procedures for the Helioseismic and Magnetic Imager Time-Distance Helioseismology Pipeline

    Science.gov (United States)

    Couvidat, S.; Zhao, J.; Birch, A. C.; Kosovichev, A. G.; Duvall, T. L., Jr.; Parchevsky, K.; Scherrer, P. H.

    2009-01-01

    The Helioseismic and Magnetic Imager (HMI) instrument on board the Solar Dynamics Observatory (SDO) satellite is designed to produce high-resolution Doppler velocity maps of oscillations at the solar surface with high temporal cadence. To take advantage of these high-quality oscillation data, a time-distance helioseismology pipeline has been implemented at the Joint Science Operations Center (JSOC) at Stanford University. The aim of this pipeline is to generate maps of acoustic travel times from oscillations on the solar surface, and to infer subsurface 3D flow velocities and sound-speed perturbations. The wave travel times are measured from cross covariances of the observed solar oscillation signals. For implementation into the pipeline we have investigated three different travel-time definitions developed in time-distance helioseismology: a Gabor wavelet fitting (Kosovichev and Duvall, 1997), a minimization relative to a reference cross-covariance function (Gizon and Birch, 2002), and a linearized version of the minimization method (Gizon and Birch, 2004). Using Doppler velocity data from the Michelson Doppler Imager (MDI) instrument on board SOHO, we tested and compared these definitions for the mean and difference travel-time perturbations measured from reciprocal signals. Although all three procedures return similar travel times in a quiet Sun region, the method of Gizon and Birch (2004) gives travel times that are significantly different from the others in a magnetic (active) region. Thus, for the pipeline implementation we chose the procedures of Kosovichev and Duvall (1997) and Gizon and Birch (2002). We investigated the relationships among these three travel-time definitions, their sensitivities to fitting parameters, and estimated the random errors they produce

  18. THE DISTANCE TO M104

    Energy Technology Data Exchange (ETDEWEB)

    McQuinn, Kristen B. W. [University of Texas at Austin, McDonald Observatory, 2515 Speedway, Stop C1400 Austin, TX 78712 (United States); Skillman, Evan D. [Minnesota Institute for Astrophysics, School of Physics and Astronomy, 116 Church Street, SE, University of Minnesota, Minneapolis, MN 55455 (United States); Dolphin, Andrew E. [Raytheon Company, 1151 E. Hermans Road, Tucson, AZ 85756 (United States); Berg, Danielle [Center for Gravitation, Cosmology and Astrophysics, Department of Physics, University of Wisconsin Milwaukee, 1900 East Kenwood Boulevard, Milwaukee, WI 53211 (United States); Kennicutt, Robert, E-mail: kmcquinn@astro.as.utexas.edu [Institute for Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom)

    2016-11-01

    M104 (NGC 4594; the Sombrero galaxy) is a nearby, well-studied elliptical galaxy included in scores of surveys focused on understanding the details of galaxy evolution. Despite the importance of observations of M104, a consensus distance has not yet been established. Here, we use newly obtained Hubble Space Telescope optical imaging to measure the distance to M104 based on the tip of the red giant branch (TRGB) method. Our measurement yields the distance to M104 to be 9.55 ± 0.13 ± 0.31 Mpc equivalent to a distance modulus of 29.90 ± 0.03 ± 0.07 mag. Our distance is an improvement over previous results as we use a well-calibrated, stable distance indicator, precision photometry in a optimally selected field of view, and a Bayesian maximum likelihood technique that reduces measurement uncertainties. The most discrepant previous results are due to Tully–Fisher method distances, which are likely inappropriate for M104 given its peculiar morphology and structure. Our results are part of a larger program to measure accurate distances to a sample of well-known spiral galaxies (including M51, M74, and M63) using the TRGB method.

  19. Distance between images

    Science.gov (United States)

    Gualtieri, J. A.; Le Moigne, J.; Packer, C. V.

    1992-01-01

    Comparing two binary images and assigning a quantitative measure to this comparison finds its purpose in such tasks as image recognition, image compression, and image browsing. This quantitative measurement may be computed by utilizing the Hausdorff distance of the images represented as two-dimensional point sets. In this paper, we review two algorithms that have been proposed to compute this distance, and we present a parallel implementation of one of them on the MasPar parallel processor. We study their complexity and the results obtained by these algorithms for two different types of images: a set of displaced pairs of images of Gaussian densities, and a comparison of a Canny edge image with several edge images from a hierarchical region growing code.

  20. Modern space/time geostatistics using river distances: data integration of turbidity and E. coli measurements to assess fecal contamination along the Raritan River in New Jersey.

    Science.gov (United States)

    Money, Eric S; Carter, Gail P; Serre, Marc L

    2009-05-15

    Escherichia coli (E. coli) is a widely used indicator of fecal contamination in water bodies. External contact and subsequent ingestion of bacteria coming from fecal contamination can lead to harmful health effects. Since E. coli data are sometimes limited, the objective of this study is to use secondary information in the form of turbidity to improve the assessment of E. coli at unmonitored locations. We obtained all E. coli and turbidity monitoring data available from existing monitoring networks for the 2000-2006 time period for the Raritan River Basin, New Jersey. Using collocated measurements, we developed a predictive model of E. coli from turbidity data. Using this model, soft data are constructed for E. coli given turbidity measurements at 739 space/time locations where only turbidity was measured. Finally, the Bayesian Maximum Entropy (BME) method of modern space/time geostatistics was used for the data integration of monitored and predicted E. coli data to produce maps showing E. coli concentration estimated daily across the river basin. The addition of soft data in conjunction with the use of river distances reduced estimation error by about 30%. Furthermore, based on these maps, up to 35% of river miles in the Raritan Basin had a probability of E coli impairment greater than 90% on the most polluted day of the study period.

  1. Formações císticas epidurais relacionadas a bursite interespinhosa, cisto sinovial e cisto discal Epidural cystic masses associated with interspinous bursitis, synovial and discal cysts

    Directory of Open Access Journals (Sweden)

    Frederico Guilherme de Paula Lopes Santos

    2009-04-01

    Full Text Available Os autores apresentam casos de cistos epidurais, dentre eles os cistos sinoviais, discais, do ligamento amarelo e relacionados a bursite interespinhosa, todas essas condições determinando compressão radicular, do saco dural ou estenose do canal vertebral. Descrevem as características de imagem e localização na ressonância magnética nessas diferentes afecções.The authors describe some cases of epidural cysts, namely synovial, discal, ligamentum flavum cysts, and cysts secondary to interspinous bursitis, all of these conditions determining radicular, dural sac compression or spinal canal stenosis. Magnetic resonance imaging findings and localization of these entities are described.

  2. Measurement of tibial tuberosity-trochlear groove distance: evaluation of inter- and intraobserver correlation dependent on the severity of trochlear dysplasia.

    Science.gov (United States)

    Dornacher, Daniel; Reichel, Heiko; Lippacher, Sabine

    2014-10-01

    Excessive tibial tuberosity-trochlear groove distance (TT-TG) is considered as one of the major risk factors in patellofemoral instability (PFI). TT-TG characterises the lateralisation of the tibial tuberosity and the medialisation of the trochlear groove in the case of trochlear dysplasia. The aim of this study was to assess the inter- and intraobserver reliability of the measurement of TT-TG dependent on the grade of trochlear dysplasia. Magnetic resonance imaging (MRI) scans of 99 consecutive knee joints were analysed retrospectively. Hereof, 61 knee joints presented with a history of PFI and 38 had no symptoms of PFI. After synopsis of the axial MRI scans with true lateral radiographs of the knee, the 61 knees presenting with PFI were assessed in terms of trochlear dysplasia. The knees were distributed according to the four-type classification system described by Dejour. Regarding interobserver correlation for the measurements of TT-TG in trochlear dysplasia, we found r=0.89 (type A), r=0.90 (type B), r=0.74 (type C) and 0.62 (type D) for Pearson's correlation coefficient. Regarding intraobserver correlation, we calculated r=0.89 (type A), r=0.91 (type B), r=0.77 (type C) and r=0.71 (type D), respectively. Pearson's correlation coefficient for the measurement of TT-TG in normal knees resulted in r=0.87 for interobserver correlation and r=0.90 for intraobserver correlation. Decreasing inter- and intraobserver correlation for the measurement of TT-TG with increasing severity of trochlear dysplasia was detected. In our opinion, the measurement of TT-TG is of significance in low-grade trochlear dysplasia. The final decision to perform a distal realignment procedure based on a pathological TT-TG in the presence of high-grade trochlear dysplasia should be reassessed properly. Retrospective study, Level II.

  3. Prevalence and distribution of ossification of the supra/interspinous ligaments in symptomatic patients with cervical ossification of the posterior longitudinal ligament of the spine: a CT-based multicenter cross-sectional study.

    Science.gov (United States)

    Mori, Kanji; Yoshii, Toshitaka; Hirai, Takashi; Iwanami, Akio; Takeuchi, Kazuhiro; Yamada, Tsuyoshi; Seki, Shoji; Tsuji, Takashi; Fujiyoshi, Kanehiro; Furukawa, Mitsuru; Nishimura, Soraya; Wada, Kanichiro; Koda, Masao; Furuya, Takeo; Matsuyama, Yukihiro; Hasegawa, Tomohiko; Takeshita, Katsushi; Kimura, Atsushi; Abematsu, Masahiko; Haro, Hirotaka; Ohba, Tetsuro; Watanabe, Masahiko; Katoh, Hiroyuki; Watanabe, Kei; Ozawa, Hiroshi; Kanno, Haruo; Imagama, Shiro; Ito, Zenya; Fujibayashi, Shunsuke; Yamazaki, Masashi; Matsumoto, Morio; Nakamura, Masaya; Okawa, Atsushi; Kawaguchi, Yoshiharu

    2016-12-01

    Supra/interspinous ligaments connect adjacent spinous processes and act as a stabilizer of the spine. As with other spinal ligaments, it can become ossified. However, few report have discussed ossification supra/interspinous ligaments (OSIL), so its epidemiology remains unknown. We therefore aimed to investigate the prevalence and distribution of OSIL in symptomatic patients with cervical ossification of the posterior longitudinal ligament (OPLL). The participants of our study were symptomatic patients with cervical OPLL who were diagnosed by standard radiographs of the cervical spine. The whole spine CT data as well as clinical parameters such as age and sex were obtained from 20 institutions belong to the Japanese Multicenter Research Organization for Ossification of the Spinal Ligament (JOSL). The prevalence and distribution of OSIL and the association between OSIL and clinical parameters were reviewed. The sum of the levels involved by OPLL (OP-index) and OSIL (OSI-index) as well as the prevalence of ossification of the nuchal ligament (ONL) were also investigated. A total of 234 patients with a mean age of 65 years was recruited. The CT-based evidence of OSIL was noted in 68 (54 males and 14 females) patients (29%). The distribution of OSIL showed a significant thoracic preponderance. In OSIL-positive patients, single-level involvement was noted in 19 cases (28%), whereas 49 cases (72%) presented multi-level involvement. We found a significant positive correlation between the OP-index grade and OSI-index. ONL was noted at a significantly higher rate in OSIL-positive patients compared to negative patients. The prevalence of OSIL in symptomatic patients with cervical OPLL was 29%. The distribution of OSIL showed a significant thoracic preponderance.

  4. THE DISTANCE TO M51

    Energy Technology Data Exchange (ETDEWEB)

    McQuinn, Kristen B. W. [University of Texas at Austin, McDonald Observatory, 2515 Speedway, Stop C1400 Austin, TX 78712 (United States); Skillman, Evan D. [Minnesota Institute for Astrophysics, School of Physics and Astronomy, 116 Church Street, S.E., University of Minnesota, Minneapolis, MN 55455 (United States); Dolphin, Andrew E. [Raytheon Company, 1151 E. Hermans Road, Tucson, AZ 85756 (United States); Berg, Danielle [Center for Gravitation, Cosmology and Astrophysics, Department of Physics, University of Wisconsin Milwaukee, 1900 East Kenwood Boulevard, Milwaukee, WI 53211 (United States); Kennicutt, Robert, E-mail: kmcquinn@astro.as.utexas.edu [Institute for Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom)

    2016-07-20

    Great investments of observing time have been dedicated to the study of nearby spiral galaxies with diverse goals ranging from understanding the star formation process to characterizing their dark matter distributions. Accurate distances are fundamental to interpreting observations of these galaxies, yet many of the best studied nearby galaxies have distances based on methods with relatively large uncertainties. We have started a program to derive accurate distances to these galaxies. Here we measure the distance to M51—the Whirlpool galaxy—from newly obtained Hubble Space Telescope optical imaging using the tip of the red giant branch method. We measure the distance modulus to be 8.58 ± 0.10 Mpc (statistical), corresponding to a distance modulus of 29.67 ± 0.02 mag. Our distance is an improvement over previous results as we use a well-calibrated, stable distance indicator, precision photometry in a optimally selected field of view, and a Bayesian Maximum Likelihood technique that reduces measurement uncertainties.

  5. The Distance to M51

    Science.gov (United States)

    McQuinn, Kristen. B. W.; Skillman, Evan D.; Dolphin, Andrew E.; Berg, Danielle; Kennicutt, Robert

    2016-07-01

    Great investments of observing time have been dedicated to the study of nearby spiral galaxies with diverse goals ranging from understanding the star formation process to characterizing their dark matter distributions. Accurate distances are fundamental to interpreting observations of these galaxies, yet many of the best studied nearby galaxies have distances based on methods with relatively large uncertainties. We have started a program to derive accurate distances to these galaxies. Here we measure the distance to M51—the Whirlpool galaxy—from newly obtained Hubble Space Telescope optical imaging using the tip of the red giant branch method. We measure the distance modulus to be 8.58 ± 0.10 Mpc (statistical), corresponding to a distance modulus of 29.67 ± 0.02 mag. Our distance is an improvement over previous results as we use a well-calibrated, stable distance indicator, precision photometry in a optimally selected field of view, and a Bayesian Maximum Likelihood technique that reduces measurement uncertainties. Based on observations made with the NASA/ESA Hubble Space Telescope, obtained from the Data Archive at the Space Telescope Science Institute, which is operated by the Association of Universities for Research in Astronomy, Inc., under NASA contract NAS 5-26555.

  6. Mapping cell populations in flow cytometry data for cross‐sample comparison using the Friedman–Rafsky test statistic as a distance measure

    Science.gov (United States)

    Hsiao, Chiaowen; Liu, Mengya; Stanton, Rick; McGee, Monnie; Qian, Yu

    2015-01-01

    Abstract Flow cytometry (FCM) is a fluorescence‐based single‐cell experimental technology that is routinely applied in biomedical research for identifying cellular biomarkers of normal physiological responses and abnormal disease states. While many computational methods have been developed that focus on identifying cell populations in individual FCM samples, very few have addressed how the identified cell populations can be matched across samples for comparative analysis. This article presents FlowMap‐FR, a novel method for cell population mapping across FCM samples. FlowMap‐FR is based on the Friedman–Rafsky nonparametric test statistic (FR statistic), which quantifies the equivalence of multivariate distributions. As applied to FCM data by FlowMap‐FR, the FR statistic objectively quantifies the similarity between cell populations based on the shapes, sizes, and positions of fluorescence data distributions in the multidimensional feature space. To test and evaluate the performance of FlowMap‐FR, we simulated the kinds of biological and technical sample variations that are commonly observed in FCM data. The results show that FlowMap‐FR is able to effectively identify equivalent cell populations between samples under scenarios of proportion differences and modest position shifts. As a statistical test, FlowMap‐FR can be used to determine whether the expression of a cellular marker is statistically different between two cell populations, suggesting candidates for new cellular phenotypes by providing an objective statistical measure. In addition, FlowMap‐FR can indicate situations in which inappropriate splitting or merging of cell populations has occurred during gating procedures. We compared the FR statistic with the symmetric version of Kullback–Leibler divergence measure used in a previous population matching method with both simulated and real data. The FR statistic outperforms the symmetric version of KL‐distance in distinguishing

  7. Mapping cell populations in flow cytometry data for cross-sample comparison using the Friedman-Rafsky test statistic as a distance measure.

    Science.gov (United States)

    Hsiao, Chiaowen; Liu, Mengya; Stanton, Rick; McGee, Monnie; Qian, Yu; Scheuermann, Richard H

    2016-01-01

    Flow cytometry (FCM) is a fluorescence-based single-cell experimental technology that is routinely applied in biomedical research for identifying cellular biomarkers of normal physiological responses and abnormal disease states. While many computational methods have been developed that focus on identifying cell populations in individual FCM samples, very few have addressed how the identified cell populations can be matched across samples for comparative analysis. This article presents FlowMap-FR, a novel method for cell population mapping across FCM samples. FlowMap-FR is based on the Friedman-Rafsky nonparametric test statistic (FR statistic), which quantifies the equivalence of multivariate distributions. As applied to FCM data by FlowMap-FR, the FR statistic objectively quantifies the similarity between cell populations based on the shapes, sizes, and positions of fluorescence data distributions in the multidimensional feature space. To test and evaluate the performance of FlowMap-FR, we simulated the kinds of biological and technical sample variations that are commonly observed in FCM data. The results show that FlowMap-FR is able to effectively identify equivalent cell populations between samples under scenarios of proportion differences and modest position shifts. As a statistical test, FlowMap-FR can be used to determine whether the expression of a cellular marker is statistically different between two cell populations, suggesting candidates for new cellular phenotypes by providing an objective statistical measure. In addition, FlowMap-FR can indicate situations in which inappropriate splitting or merging of cell populations has occurred during gating procedures. We compared the FR statistic with the symmetric version of Kullback-Leibler divergence measure used in a previous population matching method with both simulated and real data. The FR statistic outperforms the symmetric version of KL-distance in distinguishing equivalent from nonequivalent cell

  8. Estudo comparativo entre dois métodos de medida da distância interpupilar Comparative study between two measurement methods of interpupillary distance

    Directory of Open Access Journals (Sweden)

    Daniela Vieira Roehe

    2008-04-01

    Full Text Available OBJETIVO: O objetivo do estudo é realizar as medidas da Distância Interpupilar (DIP entre a régua milimetrada e o autorrefrator e comparar os resultados entre si. MÉTODOS: Cento e trinta e cinco pacientes foram submetidos à avaliação da DIP. Cada paciente foi examinado pelo mesmo examinador, com dois métodos: régua milimetrada e autorrefrator. RESULTADOS: Houve boa concordância entre as medidas apuradas pelos dois métodos, não apresentando diferença estatísticamente significante entre as médias e variabilidades. CONCLUSÃO: A inexatidão presente no método da régua milimetrada pode responder pelos casos com diferenças clinicamente significantes, porém proporcionalmente estes casos não invalidam a reprodutibilidade do autorrefrator.PURPOSE: There are several methods to measure the Interpupilary Distance (IPD, but the method used in most office is the milimetric ruler. Currently, the autorrefractor is used routinely to find for the subjective evaluation of the refractive error, but the IPD from the autorrefractor is often not compared with the traditional method of measurement.The objective of the study is to achieve the measures of IPD between the two methods and compare the results with each other. METHODS: One hundred and thirty-five patients underwent the assessment of the DIP. Each patient was examined by the same examiner, with two methods: milimetric ruler and autorrefractor. RESULTS: There was good agreement between the measures cleared by the two methods, showing no statistically significant difference between mean and variability. CONCLUSION: The inaccuracy in the method of the present milimetric ruler can answer the cases with clinically significant differences, however proportionately these cases do not invalidate the reproducibility of the autorrefractor.

  9. Novel measurement of spreading pattern of influenza epidemic by using weighted standard distance method: retrospective spatial statistical study of influenza, Japan, 1999-2009.

    Science.gov (United States)

    Shobugawa, Yugo; Wiafe, Seth A; Saito, Reiko; Suzuki, Tsubasa; Inaida, Shinako; Taniguchi, Kiyosu; Suzuki, Hiroshi

    2012-06-19

    Annual influenza epidemics occur worldwide resulting in considerable morbidity and mortality. Spreading pattern of influenza is not well understood because it is often hampered by the quality of surveillance data that limits the reliability of analysis. In Japan, influenza is reported on a weekly basis from 5,000 hospitals and clinics nationwide under the scheme of the National Infectious Disease Surveillance. The collected data are available to the public as weekly reports which were summarized into number of patient visits per hospital or clinic in each of the 47 prefectures. From this surveillance data, we analyzed the spatial spreading patterns of influenza epidemics using weekly weighted standard distance (WSD) from the 1999/2000 through 2008/2009 influenza seasons in Japan. WSD is a single numerical value representing the spatial compactness of influenza outbreak, which is small in case of clustered distribution and large in case of dispersed distribution. We demonstrated that the weekly WSD value or the measure of spatial compactness of the distribution of reported influenza cases, decreased to its lowest value before each epidemic peak in nine out of ten seasons analyzed. The duration between the lowest WSD week and the peak week of influenza cases ranged from minus one week to twenty weeks. The duration showed significant negative association with the proportion of influenza A/H3N2 cases in early phase of each outbreak (correlation coefficient was -0.75, P = 0.012) and significant positive association with the proportion of influenza B cases in the early phase (correlation coefficient was 0.64, P = 0.045), but positively correlated with the proportion of influenza A/H1N1 strain cases (statistically not significant). It is assumed that the lowest WSD values just before influenza peaks are due to local outbreak which results in small standard distance values. As influenza cases disperse nationwide and an epidemic reaches its peak, WSD value changed to be a

  10. Novel measurement of spreading pattern of influenza epidemic by using weighted standard distance method: retrospective spatial statistical study of influenza, Japan, 1999–2009

    Directory of Open Access Journals (Sweden)

    Shobugawa Yugo

    2012-06-01

    Full Text Available Abstract Background Annual influenza epidemics occur worldwide resulting in considerable morbidity and mortality. Spreading pattern of influenza is not well understood because it is often hampered by the quality of surveillance data that limits the reliability of analysis. In Japan, influenza is reported on a weekly basis from 5,000 hospitals and clinics nationwide under the scheme of the National Infectious Disease Surveillance. The collected data are available to the public as weekly reports which were summarized into number of patient visits per hospital or clinic in each of the 47 prefectures. From this surveillance data, we analyzed the spatial spreading patterns of influenza epidemics using weekly weighted standard distance (WSD from the 1999/2000 through 2008/2009 influenza seasons in Japan. WSD is a single numerical value representing the spatial compactness of influenza outbreak, which is small in case of clustered distribution and large in case of dispersed distribution. Results We demonstrated that the weekly WSD value or the measure of spatial compactness of the distribution of reported influenza cases, decreased to its lowest value before each epidemic peak in nine out of ten seasons analyzed. The duration between the lowest WSD week and the peak week of influenza cases ranged from minus one week to twenty weeks. The duration showed significant negative association with the proportion of influenza A/H3N2 cases in early phase of each outbreak (correlation coefficient was −0.75, P = 0.012 and significant positive association with the proportion of influenza B cases in the early phase (correlation coefficient was 0.64, P = 0.045, but positively correlated with the proportion of influenza A/H1N1 strain cases (statistically not significant. It is assumed that the lowest WSD values just before influenza peaks are due to local outbreak which results in small standard distance values. As influenza cases disperse nationwide and an

  11. Novel measurement of spreading pattern of influenza epidemic by using weighted standard distance method: retrospective spatial statistical study of influenza, Japan, 1999–2009

    Science.gov (United States)

    2012-01-01

    Background Annual influenza epidemics occur worldwide resulting in considerable morbidity and mortality. Spreading pattern of influenza is not well understood because it is often hampered by the quality of surveillance data that limits the reliability of analysis. In Japan, influenza is reported on a weekly basis from 5,000 hospitals and clinics nationwide under the scheme of the National Infectious Disease Surveillance. The collected data are available to the public as weekly reports which were summarized into number of patient visits per hospital or clinic in each of the 47 prefectures. From this surveillance data, we analyzed the spatial spreading patterns of influenza epidemics using weekly weighted standard distance (WSD) from the 1999/2000 through 2008/2009 influenza seasons in Japan. WSD is a single numerical value representing the spatial compactness of influenza outbreak, which is small in case of clustered distribution and large in case of dispersed distribution. Results We demonstrated that the weekly WSD value or the measure of spatial compactness of the distribution of reported influenza cases, decreased to its lowest value before each epidemic peak in nine out of ten seasons analyzed. The duration between the lowest WSD week and the peak week of influenza cases ranged from minus one week to twenty weeks. The duration showed significant negative association with the proportion of influenza A/H3N2 cases in early phase of each outbreak (correlation coefficient was −0.75, P = 0.012) and significant positive association with the proportion of influenza B cases in the early phase (correlation coefficient was 0.64, P = 0.045), but positively correlated with the proportion of influenza A/H1N1 strain cases (statistically not significant). It is assumed that the lowest WSD values just before influenza peaks are due to local outbreak which results in small standard distance values. As influenza cases disperse nationwide and an epidemic reaches its peak

  12. THE EXTRAGALACTIC DISTANCE DATABASE

    International Nuclear Information System (INIS)

    Tully, R. Brent; Courtois, Helene M.; Jacobs, Bradley A.; Rizzi, Luca; Shaya, Edward J.; Makarov, Dmitry I.

    2009-01-01

    A database can be accessed on the Web at http://edd.ifa.hawaii.edu that was developed to promote access to information related to galaxy distances. The database has three functional components. First, tables from many literature sources have been gathered and enhanced with links through a distinct galaxy naming convention. Second, comparisons of results both at the levels of parameters and of techniques have begun and are continuing, leading to increasing homogeneity and consistency of distance measurements. Third, new material is presented arising from ongoing observational programs at the University of Hawaii 2.2 m telescope, radio telescopes at Green Bank, Arecibo, and Parkes and with the Hubble Space Telescope. This new observational material is made available in tandem with related material drawn from archives and passed through common analysis pipelines.

  13. Analytic processing of distance.

    Science.gov (United States)

    Dopkins, Stephen; Galyer, Darin

    2018-01-01

    How does a human observer extract from the distance between two frontal points the component corresponding to an axis of a rectangular reference frame? To find out we had participants classify pairs of small circles, varying on the horizontal and vertical axes of a computer screen, in terms of the horizontal distance between them. A response signal controlled response time. The error rate depended on the irrelevant vertical as well as the relevant horizontal distance between the test circles with the relevant distance effect being larger than the irrelevant distance effect. The results implied that the horizontal distance between the test circles was imperfectly extracted from the overall distance between them. The results supported an account, derived from the Exemplar Based Random Walk model (Nosofsky & Palmieri, 1997), under which distance classification is based on the overall distance between the test circles, with relevant distance being extracted from overall distance to the extent that the relevant and irrelevant axes are differentially weighted so as to reduce the contribution of irrelevant distance to overall distance. The results did not support an account, derived from the General Recognition Theory (Ashby & Maddox, 1994), under which distance classification is based on the relevant distance between the test circles, with the irrelevant distance effect arising because a test circle's perceived location on the relevant axis depends on its location on the irrelevant axis, and with relevant distance being extracted from overall distance to the extent that this dependency is absent. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Tracking frequency laser distance gauge

    International Nuclear Information System (INIS)

    Phillips, J.D.; Reasenberg, R.D.

    2005-01-01

    Advanced astronomical missions with greatly enhanced resolution and physics missions of unprecedented accuracy will require laser distance gauges of substantially improved performance. We describe a laser gauge, based on Pound-Drever-Hall locking, in which the optical frequency is adjusted to maintain an interferometer's null condition. This technique has been demonstrated with pm performance. Automatic fringe hopping allows it to track arbitrary distance changes. The instrument is intrinsically free of the nm-scale cyclic bias present in traditional (heterodyne) high-precision laser gauges. The output is a radio frequency, readily measured to sufficient accuracy. The laser gauge has operated in a resonant cavity, which improves precision, can suppress the effects of misalignments, and makes possible precise automatic alignment. The measurement of absolute distance requires little or no additional hardware, and has also been demonstrated. The proof-of-concept version, based on a stabilized HeNe laser and operating on a 0.5 m path, has achieved 10 pm precision with 0.1 s integration time, and 0.1 mm absolute distance accuracy. This version has also followed substantial distance changes as fast as 16 mm/s. We show that, if the precision in optical frequency is a fixed fraction of the linewidth, both incremental and absolute distance precision are independent of the distance measured. We discuss systematic error sources, and present plans for a new version of the gauge based on semiconductor lasers and fiber-coupled components

  15. Accuracy of a 10 Hz GPS Unit in Measuring Shuttle Velocity Performed at Different Speeds and Distances (5 – 20 M

    Directory of Open Access Journals (Sweden)

    Beato Marco

    2016-12-01

    Full Text Available The aim of this study was to validate the accuracy of a 10 Hz GPS device (STATSports, Ireland by comparing the instantaneous values of velocity determined with this device with those determined by kinematic (video analysis (25 Hz. Ten male soccer players were required to perform shuttle runs (with 180° change of direction at three velocities (slow: 2.2 m·s-1; moderate: 3.2 m·s-1; high: maximal over four distances: 5, 10, 15 and 20 m. The experiments were video-recorded; the “point by point” values of speed recorded by the GPS device were manually downloaded and analysed in the same way as the “frame by frame” values of horizontal speed as obtained by video analysis. The obtained results indicated that shuttle distance was smaller in GPS than video analysis (p < 0.01. Shuttle velocity (shuttle distance/shuttle time was thus smaller in GPS than in video analysis (p < 0.001; the percentage difference (bias, % in shuttle velocity between methods was found to decrease with the distance covered (5 m: 9 ± 6%; 20 m: 3 ± 3%. The instantaneous values of speed were averaged; from these data and from data of shuttle time, the distance covered was recalculated; the error (criterion distance-recalculated distance was negligible for video data (0.04 ± 0.28 m whereas GPS data underestimated criterion distance (0.31 ± 0.55 m. In conclusion, the inaccuracy of this GPS unit in determining shuttle speed can be attributed to inaccuracy in determining the shuttle distance.

  16. Vehicle based localization system for locomotives on the base of slip depending distance measurment; Fahrzeugautarkes Ortungssystem fuer Lokomotiven auf der Basis schlupfbehafteter Wegmessung

    Energy Technology Data Exchange (ETDEWEB)

    Scholz, C.

    2003-07-01

    More and more railway operating companies use telematic systems for a more efficient use of their infrastructure in order to improve their traffic products. Almost every telematic task requires a vehicle localization. Thus a high demand for localization systems emerges. In many cases the high cost of investment and a growing attentiveness for cost efficiency hinders the implementation of high performance systems. This thesis describes the development and testing of a vehicle based localization system for locomotives. The method is based on a distance measurement on the propelled axles. The systems estimates the wheel slip depending on the momentary traction force and vehicle speed and corrects the original measurement. The special thing about this system is, that it uses only the existing technical infrastructure of locomotives. So there is no need to provide costly extra sensors. Thus the system could be installed with little preparation at low cost in almost all locomotives of German Rail. The vehicle localization was tested as part of a one-year pilot operation of a computer based energy efficient train control system (Energiesparende Fahrweise: ESF) of German Rail. During this time the system proofed a significant reduction of the distance measurement error caused by the wheel slip during regular train operation. Hence a wide range of non-safety-relevant telematic tasks would be able to use the system. This compose gives a review of important terms and aspects of localization and the characteristic connection of the friction coefficient and wheel slip of railway vehicles. The compose continues with the description of the development and testing of the system. The evaluation of the measurements and the resulting performance and quality of the localization information show the suitability of the system for an operational vehicle localization of medium quality at low cost. (orig.) [German] Telematische Systeme helfen de Eisenbahn-Betreibern, die Verkehrswege

  17. Ultrametric Distance in Syntax

    Directory of Open Access Journals (Sweden)

    Roberts Mark D.

    2015-04-01

    Full Text Available Phrase structure trees have a hierarchical structure. In many subjects, most notably in taxonomy such tree structures have been studied using ultrametrics. Here syntactical hierarchical phrase trees are subject to a similar analysis, which is much simpler as the branching structure is more readily discernible and switched. The ambiguity of which branching height to choose, is resolved by postulating that branching occurs at the lowest height available. An ultrametric produces a measure of the complexity of sentences: presumably the complexity of sentences increases as a language is acquired so that this can be tested. All ultrametric triangles are equilateral or isosceles. Here it is shown that X̅ structure implies that there are no equilateral triangles. Restricting attention to simple syntax a minimum ultrametric distance between lexical categories is calculated. A matrix constructed from this ultrametric distance is shown to be different than the matrix obtained from features. It is shown that the definition of C-COMMAND can be replaced by an equivalent ultrametric definition. The new definition invokes a minimum distance between nodes and this is more aesthetically satisfying than previous varieties of definitions. From the new definition of C-COMMAND follows a new definition of of the central notion in syntax namely GOVERNMENT.

  18. SU-F-T-658: Out-Of-Field Dose Comparison for TrueBeam Low Energy Beams for Extended Distances: Measurement Vs Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Wijesooriya, K [University of Virginia Health Systems, Charlottesville, VA (United States); University of Virginia, Charlottesville, VA (United States); Liyanage, N; Kaluarachchi, M [University of Virginia, Charlottesville, VA (United States); Sawkey, D [Varian Medical Systems, Palo Alto, CA (United States)

    2016-06-15

    Purpose: Patient dose far from the treatment field is comprised of scatter from within the patient, and treatment head leakage. We quantify the treatment head leakage for TrueBeam linear accelerator for 6X and 6X-FFF beams by comparing measurements to Monte Carlo simulations for a variety of jaw sizes and collimator rotations. This work is conceptually similar to that of Kry et al. (Medical Physics 2006; 33: 4405), who considered a Clinac linear accelerator. Methods: Measurements were made using an EXRADIN A101 ion chamber positioned in the patient plane, at distances up to 100 cm from isocenter. Simulations were done using VirtuaLinac, the GEANT4-based Monte Carlo model of the TrueBeam treatment head, and an in-house (U. Virginia) GEANT4-based code. In-house code modelled an ion chamber with build-up, based on a CT scan of the chamber. VirtuaLinac included a detailed model of the treatment head shielding, and was run on the Amazon Web Services cloud to generate spherical phase space files surrounding the treatment head. These phase space files were imported into the in-house code. Results: Initial comparisons between measurements and simulation showed an excess of dose in the in-plane direction, away from the gantry, in the simulations. This was traced to an incomplete model of the shielding—specifically, the component holding the primary collimator was smaller in the model than in the TrueBeam. Modifications were made to VirtuaLinac to more closely match the engineering drawings. In the in-plane direction, the lowest out of field dose was away from gantry (negative abscissa values) at around 60 cm from isocenter, for fields smaller than 10×10 cm2. Out of field dose decreased with decreasing jaw size. Flattening-filter free beam produced out-of-field doses as low as 65% of those with flattened beam. Conclusion: Doses determined from simulation and measurement were in close agreement. Funding support from the Jefferson Trust Foundation.

  19. Landscape features influence gene flow as measured by cost-distance and genetic analyses: a case study for giant pandas in the Daxiangling and Xiaoxiangling Mountains

    Directory of Open Access Journals (Sweden)

    Wei Fuwen

    2010-07-01

    Full Text Available Abstract Background Gene flow maintains genetic diversity within a species and is influenced by individual behavior and the geographical features of the species' habitat. Here, we have characterized the geographical distribution of genetic patterns in giant pandas (Ailuropoda melanoleuca living in four isolated patches of the Xiaoxiangling and Daxiangling Mountains. Three geographic distance definitions were used with the "isolation by distance theory": Euclidean distance (EUD, least-cost path distance (LCD defined by food resources, and LCD defined by habitat suitability. Results A total of 136 genotypes were obtained from 192 fecal samples and one blood sample, corresponding to 53 unique genotypes. Geographical maps plotted at high resolution using smaller neighborhood radius definitions produced large cost distances, because smaller radii include a finer level of detail in considering each pixel. Mantel tests showed that most correlation indices, particularly bamboo resources defined for different sizes of raster cell, were slightly larger than the correlations calculated for the Euclidean distance, with the exception of Patch C. We found that natural barriers might have decreased gene flow between the Xiaoxiangling and Daxiangling regions. Conclusions Landscape features were found to partially influence gene flow in the giant panda population. This result is closely linked to the biological character and behavior of giant pandas because, as bamboo feeders, individuals spend most of their lives eating bamboo or moving within the bamboo forest. Landscape-based genetic analysis suggests that gene flow will be enhanced if the connectivity between currently fragmented bamboo forests is increased.

  20. Training for Distance Teaching through Distance Learning.

    Science.gov (United States)

    Cadorath, Jill; Harris, Simon; Encinas, Fatima

    2002-01-01

    Describes a mixed-mode bachelor degree course in English language teaching at the Universidad Autonoma de Puebla (Mexico) that was designed to help practicing teachers write appropriate distance education materials by giving them the experience of being distance students. Includes a course outline and results of a course evaluation. (Author/LRW)

  1. Hierarchical traits distances explain grassland Fabaceae species' ecological niches distances

    Science.gov (United States)

    Fort, Florian; Jouany, Claire; Cruz, Pablo

    2015-01-01

    Fabaceae species play a key role in ecosystem functioning through their capacity to fix atmospheric nitrogen via their symbiosis with Rhizobium bacteria. To increase benefits of using Fabaceae in agricultural systems, it is necessary to find ways to evaluate species or genotypes having potential adaptations to sub-optimal growth conditions. We evaluated the relevance of phylogenetic distance, absolute trait distance and hierarchical trait distance for comparing the adaptation of 13 grassland Fabaceae species to different habitats, i.e., ecological niches. We measured a wide range of functional traits (root traits, leaf traits, and whole plant traits) in these species. Species phylogenetic and ecological distances were assessed from a species-level phylogenetic tree and species' ecological indicator values, respectively. We demonstrated that differences in ecological niches between grassland Fabaceae species were related more to their hierarchical trait distances than to their phylogenetic distances. We showed that grassland Fabaceae functional traits tend to converge among species with the same ecological requirements. Species with acquisitive root strategies (thin roots, shallow root systems) are competitive species adapted to non-stressful meadows, while conservative ones (coarse roots, deep root systems) are able to tolerate stressful continental climates. In contrast, acquisitive species appeared to be able to tolerate low soil-P availability, while conservative ones need high P availability. Finally we highlight that traits converge along the ecological gradient, providing the assumption that species with similar root-trait values are better able to coexist, regardless of their phylogenetic distance. PMID:25741353

  2. Hierarchical traits distances explain grassland Fabaceae species’ ecological niches distances

    Directory of Open Access Journals (Sweden)

    Florian eFort

    2015-02-01

    Full Text Available Fabaceae species play a key role in ecosystem functioning through their capacity to fix atmospheric nitrogen via their symbiosis with Rhizobium bacteria. To increase benefits of using Fabaceae in agricultural systems, it is necessary to find ways to evaluate species or genotypes having potential adaptations to sub-optimal growth conditions. We evaluated the relevance of phylogenetic distance, absolute trait distance and hierarchical trait distance for comparing the adaptation of 13 grassland Fabaceae species to different habitats, i.e. ecological niches. We measured a wide range of functional traits (root traits, leaf traits and whole plant traits in these species. Species phylogenetic and ecological distances were assessed from a species-level phylogenetic tree and species’ ecological indicator values, respectively. We demonstrated that differences in ecological niches between grassland Fabaceae species were related more to their hierarchical trait distances than to their phylogenetic distances. We showed that grassland Fabaceae functional traits tend to converge among species with the same ecological requirements. Species with acquisitive root strategies (thin roots, shallow root systems are competitive species adapted to non-stressful meadows, while conservative ones (coarse roots, deep root systems are able to tolerate stressful continental climates. In contrast, acquisitive species appeared to be able to tolerate low soil-P availability, while conservative ones need high P availability. Finally we highlight that traits converge along the ecological gradient, providing the assumption that species with similar root-trait values are better able to coexist, regardless of their phylogenetic distance.

  3. Conformational changes in human serum albumin studied by fluorescence and absorption spectroscopy. Distance measurements as a function of pH and fatty acids

    DEFF Research Database (Denmark)

    Honoré, B; Pedersen, A O

    1989-01-01

    pH- and fatty acid-induced conformational changes in human serum albumin were investigated by fluorescence-energy transfer, determining the distance between Trp-214 and bound bilirubin at 25 degrees C. This distance changes significantly with the pH, being 2.52 +/- 0.01 nm at pH 6, 2.31 +/- 0.04 nm...... at pH 9, 2.13 +/- 0.07 nm at pH 11.0 and 2.77 nm at pH 11.9. The influence of different fatty acids on the distance was also determined. At pH 7.4 medium-chain fatty acids seem to increase this distance, whereas long-chain fatty acids, at low concentrations, decrease the distance between the two...... chromophores. The contraction of the protein carrying long-chain saturated fatty acids is even more pronounced at pH 9. Udgivelsesdato: 1989-Feb-15...

  4. Continuity Properties of Distances for Markov Processes

    DEFF Research Database (Denmark)

    Jaeger, Manfred; Mao, Hua; Larsen, Kim Guldstrand

    2014-01-01

    In this paper we investigate distance functions on finite state Markov processes that measure the behavioural similarity of non-bisimilar processes. We consider both probabilistic bisimilarity metrics, and trace-based distances derived from standard Lp and Kullback-Leibler distances. Two desirable...

  5. Encyclopedia of distances

    CERN Document Server

    Deza, Michel Marie

    2014-01-01

    This updated and revised third edition of the leading reference volume on distance metrics includes new items from very active research areas in the use of distances and metrics such as geometry, graph theory, probability theory and analysis. Among the new topics included are, for example, polyhedral metric space, nearness matrix problems, distances between belief assignments, distance-related animal settings, diamond-cutting distances, natural units of length, Heidegger’s de-severance distance, and brain distances. The publication of this volume coincides with intensifying research efforts into metric spaces and especially distance design for applications. Accurate metrics have become a crucial goal in computational biology, image analysis, speech recognition and information retrieval. Leaving aside the practical questions that arise during the selection of a ‘good’ distance function, this work focuses on providing the research community with an invaluable comprehensive listing of the main available di...

  6. Language distance and tree reconstruction

    International Nuclear Information System (INIS)

    Petroni, Filippo; Serva, Maurizio

    2008-01-01

    Languages evolve over time according to a process in which reproduction, mutation and extinction are all possible. This is very similar to haploid evolution for asexual organisms and for the mitochondrial DNA of complex ones. Exploiting this similarity, it is possible, in principle, to verify hypotheses concerning the relationship among languages and to reconstruct their family tree. The key point is the definition of the distances among pairs of languages in analogy with the genetic distances among pairs of organisms. Distances can be evaluated by comparing grammar and/or vocabulary, but while it is difficult, if not impossible, to quantify grammar distance, it is possible to measure a distance from vocabulary differences. The method used by glottochronology computes distances from the percentage of shared 'cognates', which are words with a common historical origin. The weak point of this method is that subjective judgment plays a significant role. Here we define the distance of two languages by considering a renormalized edit distance among words with the same meaning and averaging over the two hundred words contained in a Swadesh list. In our approach the vocabulary of a language is the analogue of DNA for organisms. The advantage is that we avoid subjectivity and, furthermore, reproducibility of results is guaranteed. We apply our method to the Indo-European and the Austronesian groups, considering, in both cases, fifty different languages. The two trees obtained are, in many respects, similar to those found by glottochronologists, with some important differences as regards the positions of a few languages. In order to support these different results we separately analyze the structure of the distances of these languages with respect to all the others

  7. Language distance and tree reconstruction

    Science.gov (United States)

    Petroni, Filippo; Serva, Maurizio

    2008-08-01

    Languages evolve over time according to a process in which reproduction, mutation and extinction are all possible. This is very similar to haploid evolution for asexual organisms and for the mitochondrial DNA of complex ones. Exploiting this similarity, it is possible, in principle, to verify hypotheses concerning the relationship among languages and to reconstruct their family tree. The key point is the definition of the distances among pairs of languages in analogy with the genetic distances among pairs of organisms. Distances can be evaluated by comparing grammar and/or vocabulary, but while it is difficult, if not impossible, to quantify grammar distance, it is possible to measure a distance from vocabulary differences. The method used by glottochronology computes distances from the percentage of shared 'cognates', which are words with a common historical origin. The weak point of this method is that subjective judgment plays a significant role. Here we define the distance of two languages by considering a renormalized edit distance among words with the same meaning and averaging over the two hundred words contained in a Swadesh list. In our approach the vocabulary of a language is the analogue of DNA for organisms. The advantage is that we avoid subjectivity and, furthermore, reproducibility of results is guaranteed. We apply our method to the Indo-European and the Austronesian groups, considering, in both cases, fifty different languages. The two trees obtained are, in many respects, similar to those found by glottochronologists, with some important differences as regards the positions of a few languages. In order to support these different results we separately analyze the structure of the distances of these languages with respect to all the others.

  8. Distance-regular graphs

    NARCIS (Netherlands)

    van Dam, Edwin R.; Koolen, Jack H.; Tanaka, Hajime

    2016-01-01

    This is a survey of distance-regular graphs. We present an introduction to distance-regular graphs for the reader who is unfamiliar with the subject, and then give an overview of some developments in the area of distance-regular graphs since the monograph 'BCN'[Brouwer, A.E., Cohen, A.M., Neumaier,

  9. Measurement of kVp, PPV and air kerma values in function of the electric current quantity and the focus-detector distance in one X-ray equipment

    International Nuclear Information System (INIS)

    Lucena, Rodrigo F. de; Potiens, Maria da Penha A.; Vivolo, Vitor

    2009-01-01

    The objective of this work was to study the behavior of the X-ray equipment Pantak/Seifert, model MXR-160/22 of the calibration laboratory of IPEN, LCI, operating in the diagnostic radiology radiation quality RQR 5 (70 kV). For this evaluation it was used a noninvasive meter PTW, Diavolt TM model. The measurements of kVp, PPV and Dose (air kerma), were made varying the electric current and distance between the focal point and the meter. This behavior is described in the literature and was expected in the analysis of the measurements for comparison purposes. For the tests where it was only increased the electric current it was waited a linear increase of the dose (air kerma), but not a variation in the kVp and PPV. The measurements had corresponded to the waited behavior, since the Dose (air kerma) measurements presented a linear increase with the increase of the electric current and the kVp and PPV values showed a variation less than 2%. In the corresponding measurements increasing the distance between focal point and meter, it was waited the exponentially decreasing of the Dose (air kerma) and again a small variation or no variation of the PPV and kVP with the increase of the distance. Over again the measurements corresponded to the expected, where the Dose (air kerma) decreased exponentially and the PPV and the kVp had a variation less than 1.5%. (author)

  10. Influence of local molecular motions on the determination of 1H-1H internuclear distances measured by 2D 1H spin-exchange experiments

    Czech Academy of Sciences Publication Activity Database

    Brus, Jiří; Petříčková, H.; Dybal, Jiří

    2003-01-01

    Roč. 23, č. 4 (2003), s. 183-197 ISSN 0926-2040 R&D Projects: GA AV ČR IAB4050203; GA AV ČR IAA4050208; GA ČR GA203/99/0067 Institutional research plan: CEZ:AV0Z4050913 Keywords : H-1-H-1 spin exchange * interatomic distances * molecular motion Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.453, year: 2003

  11. Fluctuation analysis of the time dynamics of laser distance data measured in the medieval Jeroným Mine (Czech Republic)

    Czech Academy of Sciences Publication Activity Database

    Telesca, L.; Lovallo, M.; Kaláb, Zdeněk; Lednická, Markéta

    2011-01-01

    Roč. 20, č. 390 (2011), s. 3551-3557 ISSN 0378-4371 R&D Projects: GA ČR GA105/09/0089 Institutional research plan: CEZ:AV0Z30860518 Keywords : laser distance * scaling * fractal tools Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 1.373, year: 2011 http://www.sciencedirect.com/science/article/pii/S0378437111003219

  12. Interface Simulation Distances

    Directory of Open Access Journals (Sweden)

    Pavol Černý

    2012-10-01

    Full Text Available The classical (boolean notion of refinement for behavioral interfaces of system components is the alternating refinement preorder. In this paper, we define a distance for interfaces, called interface simulation distance. It makes the alternating refinement preorder quantitative by, intuitively, tolerating errors (while counting them in the alternating simulation game. We show that the interface simulation distance satisfies the triangle inequality, that the distance between two interfaces does not increase under parallel composition with a third interface, and that the distance between two interfaces can be bounded from above and below by distances between abstractions of the two interfaces. We illustrate the framework, and the properties of the distances under composition of interfaces, with two case studies.

  13. Tourists consuming distance

    DEFF Research Database (Denmark)

    Larsen, Gunvor Riber

    The environmental impact of tourism mobility is linked to the distances travelled in order to reach a holiday destination, and with tourists travelling more and further than previously, an understanding of how the tourists view the distance they travel across becomes relevant. Based on interviews...... contribute to an understanding of how it is possible to change tourism travel behaviour towards becoming more sustainable. How tourists 'consume distance' is discussed, from the practical level of actually driving the car or sitting in the air plane, to the symbolic consumption of distance that occurs when...... travelling on holiday becomes part of a lifestyle and a social positioning game. Further, different types of tourist distance consumers are identified, ranging from the reluctant to the deliberate and nonchalant distance consumers, who display very differing attitudes towards the distance they all travel...

  14. Distance Education in Technological Age

    Directory of Open Access Journals (Sweden)

    R .C. SHARMA

    2005-04-01

    Education in the area of Educational Technology and has been working as Regional Director in Indira Gandhi National Open University (IGNOU since 1996. Before joining IGNOU, Dr Sharma was a member at a Senior Faculty in a Teacher Training College for nearly ten years and taught Educational Technology, Educational Research and Statistics, Educational Measurement and Evaluation, Psychodynamics of Mental Health Courses for the B.Ed. and M.Ed. Programmes. He has conducted many training programmes for the in- and pre-service teachers on the use of Multimedia in teaching and instruction, and established a Centre of ICT in the College he was working. He is a member of many committees on implementation of technology in the Open University. His areas of specialization include ICT applications, computer networking, online learning, student support services in open and distance learning, and teacher education. Currently, he's on the Editorial Advisory Board of “Distance Education” published by Carfax Publishing, an imprint of the international academic publishing house, the Taylor & Francis Group, UK for 2002-2003; “International Review of Research in Open and Distance Learning”, online journal published by Athabasca University, Canada, www.irrodl.org, and “Turkish Online Journal of Distance Education” published by Anadolu University, Turkey (http://tojde.anadolu.edu.tr. He has recently joined the editorial team for Journal of IT Education, http://jite.org. He was also on the Editorial Advisory Board of “Indian Journal of Open Learning” published by IGNOU, and worked as an Associate Editor for “Staff and Educational Development International” ISSN 0971-9008 and “Global e-Journal of Open and Flexible Learning”. He has co-authored one book on distance education research and is currently co-editing a book on Interactive Multimedia in Education and Training to be published by IDEA group, USA . Ramesh C. Sharma, PhDRegional DirectorIndira Gandhi National Open University Regional

  15. Traversing psychological distance.

    Science.gov (United States)

    Liberman, Nira; Trope, Yaacov

    2014-07-01

    Traversing psychological distance involves going beyond direct experience, and includes planning, perspective taking, and contemplating counterfactuals. Consistent with this view, temporal, spatial, and social distances as well as hypotheticality are associated, affect each other, and are inferred from one another. Moreover, traversing all distances involves the use of abstraction, which we define as forming a belief about the substitutability for a specific purpose of subjectively distinct objects. Indeed, across many instances of both abstraction and psychological distancing, more abstract constructs are used for more distal objects. Here, we describe the implications of this relation for prediction, choice, communication, negotiation, and self-control. We ask whether traversing distance is a general mental ability and whether distance should replace expectancy in expected-utility theories. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Adaptive Distance Protection for Microgrids

    DEFF Research Database (Denmark)

    Lin, Hengwei; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2015-01-01

    is adopted to accelerate the tripping speed of the relays on the weak lines. The protection methodology is tested on a mid-voltage microgrid network in Aalborg, Denmark. The results show that the adaptive distance protection methodology has good selectivity and sensitivity. What is more, this system also has......Due to the increasing penetration of distributed generation resources, more and more microgrids can be found in distribution systems. This paper proposes a phasor measurement unit based distance protection strategy for microgrids in distribution system. At the same time, transfer tripping scheme...

  17. Numerical distance protection

    CERN Document Server

    Ziegler, Gerhard

    2011-01-01

    Distance protection provides the basis for network protection in transmission systems and meshed distribution systems. This book covers the fundamentals of distance protection and the special features of numerical technology. The emphasis is placed on the application of numerical distance relays in distribution and transmission systems.This book is aimed at students and engineers who wish to familiarise themselves with the subject of power system protection, as well as the experienced user, entering the area of numerical distance protection. Furthermore it serves as a reference guide for s

  18. Intersubunit distances in full-length, dimeric, bacterial phytochrome Agp1, as measured by pulsed electron-electron double resonance (PELDOR) between different spin label positions, remain unchanged upon photoconversion.

    Science.gov (United States)

    Kacprzak, Sylwia; Njimona, Ibrahim; Renz, Anja; Feng, Juan; Reijerse, Edward; Lubitz, Wolfgang; Krauss, Norbert; Scheerer, Patrick; Nagano, Soshichiro; Lamparter, Tilman; Weber, Stefan

    2017-05-05

    Bacterial phytochromes are dimeric light-regulated histidine kinases that convert red light into signaling events. Light absorption by the N-terminal photosensory core module (PCM) causes the proteins to switch between two spectrally distinct forms, Pr and Pfr, thus resulting in a conformational change that modulates the C-terminal histidine kinase region. To provide further insights into structural details of photoactivation, we investigated the full-length Agp1 bacteriophytochrome from the soil bacterium Agrobacterium fabrum using a combined spectroscopic and modeling approach. We generated seven mutants suitable for spin labeling to enable application of pulsed EPR techniques. The distances between attached spin labels were measured using pulsed electron-electron double resonance spectroscopy to probe the arrangement of the subunits within the dimer. We found very good agreement of experimental and calculated distances for the histidine-kinase region when both subunits are in a parallel orientation. However, experimental distance distributions surprisingly showed only limited agreement with either parallel- or antiparallel-arranged dimer structures when spin labels were placed into the PCM region. This observation indicates that the arrangements of the PCM subunits in the full-length protein dimer in solution differ significantly from that in the PCM crystals. The pulsed electron-electron double resonance data presented here revealed either no or only minor changes of distance distributions upon Pr-to-Pfr photoconversion. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  19. Machine learning enhanced optical distance sensor

    Science.gov (United States)

    Amin, M. Junaid; Riza, N. A.

    2018-01-01

    Presented for the first time is a machine learning enhanced optical distance sensor. The distance sensor is based on our previously demonstrated distance measurement technique that uses an Electronically Controlled Variable Focus Lens (ECVFL) with a laser source to illuminate a target plane with a controlled optical beam spot. This spot with varying spot sizes is viewed by an off-axis camera and the spot size data is processed to compute the distance. In particular, proposed and demonstrated in this paper is the use of a regularized polynomial regression based supervised machine learning algorithm to enhance the accuracy of the operational sensor. The algorithm uses the acquired features and corresponding labels that are the actual target distance values to train a machine learning model. The optimized training model is trained over a 1000 mm (or 1 m) experimental target distance range. Using the machine learning algorithm produces a training set and testing set distance measurement errors of learning. Applications for the proposed sensor include industrial scenario distance sensing where target material specific training models can be generated to realize low <1% measurement error distance measurements.

  20. Distance-transitive graphs

    NARCIS (Netherlands)

    Cohen, A.M.; Beineke, L.W.; Wilson, R.J.; Cameron, P.J.

    2004-01-01

    In this chapter we investigate the classification of distance-transitive graphs: these are graphs whose automorphism groups are transitive on each of the sets of pairs of vertices at distance i, for i = 0, 1,.... We provide an introduction into the field. By use of the classification of finite

  1. Distance Education in Entwicklungslandern.

    Science.gov (United States)

    German Foundation for International Development, Bonn (West Germany).

    Seminar and conference reports and working papers on distance education of adults, which reflect the experiences of many countries, are presented. Contents include the draft report of the 1979 International Seminar on Distance Education held in Addis Ababa, Ethiopia, which was jointly sponsored by the United Nations Economic Commission for Africa…

  2. Encyclopedia of distances

    CERN Document Server

    Deza, Michel Marie

    2009-01-01

    Distance metrics and distances have become an essential tool in many areas of pure and applied Mathematics. This title offers both independent introductions and definitions, while at the same time making cross-referencing easy through hyperlink-like boldfaced references to original definitions.

  3. Distance Education in Turkey

    Directory of Open Access Journals (Sweden)

    Dr. Nursel Selver RUZGAR,

    2004-04-01

    Full Text Available Distance Education in Turkey Assistant Professor Dr. Nursel Selver RUZGAR Technical Education Faculty Marmara University, TURKEY ABSTRACT Many countries of the world are using distance education with various ways, by internet, by post and by TV. In this work, development of distance education in Turkey has been presented from the beginning. After discussing types and applications for different levels of distance education in Turkey, the distance education was given in the cultural aspect of the view. Then, in order to create the tendencies and thoughts of graduates of Higher Education Institutions and Distance Education Institutions about being competitors in job markets, sufficiency of education level, advantages for education system, continuing education in different Institutions, a face-to-face survey was applied to 1284 graduates, 958 from Higher Education Institutions and 326 from Distance Education Institutions. The results were evaluated and discussed. In the last part of this work, suggestions to become widespread and improve the distance education in the country were made.

  4. Dissolution comparisons using a Multivariate Statistical Distance (MSD) test and a comparison of various approaches for calculating the measurements of dissolution profile comparison.

    Science.gov (United States)

    Cardot, J-M; Roudier, B; Schütz, H

    2017-07-01

    The f 2 test is generally used for comparing dissolution profiles. In cases of high variability, the f 2 test is not applicable, and the Multivariate Statistical Distance (MSD) test is frequently proposed as an alternative by the FDA and EMA. The guidelines provide only general recommendations. MSD tests can be performed either on raw data with or without time as a variable or on parameters of models. In addition, data can be limited-as in the case of the f 2 test-to dissolutions of up to 85% or to all available data. In the context of the present paper, the recommended calculation included all raw dissolution data up to the first point greater than 85% as a variable-without the various times as parameters. The proposed MSD overcomes several drawbacks found in other methods.

  5. Distance measurements across randomly distributed nitroxide probes from the temperature dependence of the electron spin phase memory time at 240 GHz

    Science.gov (United States)

    Edwards, Devin T.; Takahashi, Susumu; Sherwin, Mark S.; Han, Songi

    2012-10-01

    At 8.5 T, the polarization of an ensemble of electron spins is essentially 100% at 2 K, and decreases to 30% at 20 K. The strong temperature dependence of the electron spin polarization between 2 and 20 K leads to the phenomenon of spin bath quenching: temporal fluctuations of the dipolar magnetic fields associated with the energy-conserving spin "flip-flop" process are quenched as the temperature of the spin bath is lowered to the point of nearly complete spin polarization. This work uses pulsed electron paramagnetic resonance (EPR) at 240 GHz to investigate the effects of spin bath quenching on the phase memory times (TM) of randomly-distributed ensembles of nitroxide molecules below 20 K at 8.5 T. For a given electron spin concentration, a characteristic, dipolar flip-flop rate (W) is extracted by fitting the temperature dependence of TM to a simple model of decoherence driven by the spin flip-flop process. In frozen solutions of 4-Amino-TEMPO, a stable nitroxide radical in a deuterated water-glass, a calibration is used to quantify average spin-spin distances as large as r¯=6.6 nm from the dipolar flip-flop rate. For longer distances, nuclear spin fluctuations, which are not frozen out, begin to dominate over the electron spin flip-flop processes, placing an effective ceiling on this method for nitroxide molecules. For a bulk solution with a three-dimensional distribution of nitroxide molecules at concentration n, we find W∝n∝1/r, which is consistent with magnetic dipolar spin interactions. Alternatively, we observe W∝n for nitroxides tethered to a quasi two-dimensional surface of large (Ø ˜ 200 nm), unilamellar, lipid vesicles, demonstrating that the quantification of spin bath quenching can also be used to discern the geometry of molecular assembly or organization.

  6. Robustness of Distance-to-Default

    DEFF Research Database (Denmark)

    Jessen, Cathrine; Lando, David

    2013-01-01

    Distance-to-default is a remarkably robust measure for ranking firms according to their risk of default. The ranking seems to work despite the fact that the Merton model from which the measure is derived produces default probabilities that are far too small when applied to real data. We use...... simulations to investigate the robustness of the distance-to-default measure to different model specifications. Overall we find distance-to-default to be robust to a number of deviations from the simple Merton model that involve different asset value dynamics and different default triggering mechanisms....... A notable exception is a model with stochastic volatility of assets. In this case both the ranking of firms and the estimated default probabilities using distance-to-default perform significantly worse. We therefore propose a volatility adjustment of the distance-to-default measure, that significantly...

  7. REPRESENTATIONS OF DISTANCE: DIFFERENCES IN UNDERSTANDING DISTANCE ACCORDING TO TRAVEL METHOD

    Directory of Open Access Journals (Sweden)

    Gunvor Riber Larsen

    2017-12-01

    Full Text Available This paper explores how Danish tourists represent distance in relation to their holiday mobility and how these representations of distance are a result of being aero-mobile as opposed to being land-mobile. Based on interviews with Danish tourists, whose holiday mobility ranges from the European continent to global destinations, the first part of this qualitative study identifies three categories of representations of distance that show how distance is being ‘translated’ by the tourists into non-geometric forms: distance as resources, distance as accessibility, and distance as knowledge. The representations of distance articulated by the Danish tourists show that distance is often not viewed in ‘just’ kilometres. Rather, it is understood in forms that express how transcending the physical distance through holiday mobility is dependent on individual social and economic contexts, and on whether the journey was undertaken by air or land. The analysis also shows that being aeromobile is the holiday transportation mode that removes the tourists the furthest away from physical distance, resulting in the distance travelled by air being represented in ways that have the least correlation, in the tourists’ minds, with physical distance measured in kilometres.

  8. A tentative theory of large distance physics

    International Nuclear Information System (INIS)

    Friedan, Daniel

    2003-01-01

    A theoretical mechanism is devised to determine the large distance physics of spacetime. It is a two dimensional nonlinear model, the lambda model, set to govern the string world surface in an attempt to remedy the failure of string theory, as it stands. The lambda model is formulated to cancel the infrared divergent effects of handles at short distance on the world surface. The target manifold is the manifold of background spacetimes. The coupling strength is the spacetime coupling constant. The lambda model operates at 2d distance Δ -1 , very much shorter than the 2d distance μ -1 where the world surface is seen. A large characteristic spacetime distance L is given by L 2 ln(Δ/μ). Spacetime fields of wave number up to 1=L are the local coordinates for the manifold of spacetimes. The distribution of fluctuations at 2d distances shorter than Δ -1 gives the a priori measure on the target manifold, the manifold of spacetimes. If this measure concentrates at a macroscopic spacetime, then, nearby, it is a measure on the spacetime fields. The lambda model thereby constructs a spacetime quantum field theory, cutoff at ultraviolet distance L, describing physics at distances larger than L. The lambda model also constructs an effective string theory with infrared cutoff L, describing physics at distances smaller than L. The lambda model evolves outward from zero 2d distance, Δ -1 = 0, building spacetime physics starting from L ∞ and proceeding downward in L. L can be taken smaller than any distance practical for experiments, so the lambda model, if right, gives all actually observable physics. The harmonic surfaces in the manifold of spacetimes are expected to have novel nonperturbative effects at large distances. (author)

  9. An fMRI Study Dissociating Distance Measures Computed by Broca’s Area in Movement Processing: Clause boundary vs Identity

    Directory of Open Access Journals (Sweden)

    Andrea eSanti

    2015-05-01

    Full Text Available Behavioral studies of sentence comprehension suggest that processing long-distance dependencies is subject to interference effects when Noun Phrases (NP similar to the dependency head intervene the dependency. Neuroimaging studies converge in localizing such effects to Broca’s area, showing that activity in Broca’s area increases with the number of NP interveners crossed by a moved NP of the same type. To test if NP interference effects are modulated by adding an intervening clause boundary, which should by hypothesis increase the number of successive-cyclic movements, we conducted an fMRI study contrasting NP interveners with clausal (CP interveners. Our design thus had two components: (I the number of NP interveners crossed by movement was parametrically modulated; (II CP-intervention was contrasted with NP-intervention. The number of NP interveners parametrically modulated a cluster straddling left BA44/45 of Broca’s area, replicating earlier studies. Adding an intervening clause boundary did not significantly modulate the size of the NP interference effect in Broca’s area. Yet, such an interaction effect was observed in the Superior Frontal Gyrus (SFG. Therefore, the involvement of Broca’s area in processing syntactic movement is best captured by memory mechanisms affected by a grammatically instantiated type-identity (ie, NP intervention.

  10. Measuring the Total-Factor Carbon Emission Performance of Industrial Land Use in China Based on the Global Directional Distance Function and Non-Radial Luenberger Productivity Index

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2016-04-01

    Full Text Available Industry is a major contributor to carbon emissions in China, and industrial land is an important input to industrial production. Therefore, a detailed analysis of the carbon emission performance of industrial land use is necessary for making reasonable carbon reduction policies that promote the sustainable use of industrial land. This paper aims to analyze the dynamic changes in the total-factor carbon emission performance of industrial land use (TCPIL in China by applying a global directional distance function (DDF and non-radial Luenberger productivity index. The empirical results show that the eastern region enjoys better TCPIL than the central and western regions, but the regional gaps in TCPIL are narrowing. The growth in NLCPILs (non-radial Luenberger carbon emission performance of industrial land use in the eastern and central regions is mainly driven by technological progress, whereas efficiency improvements contribute more to the growth of NLCPIL in the western region. The provinces in the eastern region have the most innovative and environmentally-friendly production technologies. The results of the analysis of the influencing factors show implications for improving the NLCPIL, including more investment in industrial research and development (R&D, the implementation of carbon emission reduction policies, reduction in the use of fossil energy, especially coal, in the process of industrial production, actively learning about foreign advanced technology, properly solving the problem of surplus labor in industry and the expansion of industrial development.

  11. Quality of mass-reared codling moth (Lepidoptera: Tortricidae) after long-distance transportation: 1. Logistics of shipping procedures and quality parameters as measured in the laboratory.

    Science.gov (United States)

    Blomefield, T; Carpenter, J E; Vreysen, M J B

    2011-06-01

    The sterile insect technique (SIT) is a proven effective control tactic against lepidopteran pests when applied in an areawide integrated pest management program. The construction of insect mass-rearing facilities requires considerable investment and moth control strategies that include the use of sterile insects could be made more cost-effective through the importation of sterile moths produced in other production centers. For codling moth, Cydia pomonella (L.) (Lepidoptera: Tortricidae), this is an attractive option because mating studies have confirmed the absence of mating barriers between codling moth populations from geographically different areas. To assess the feasibility of long-distance transportation of codling moths, pupae and adult moths were transported in 2004 from Canada to South Africa in four shipments by using normal commercial transport routes. The total transport time remained below 67 h in three of the consignments, but it was 89 h in the fourth consignment. Temperature in the shipping boxes was fairly constant and remained between -0.61 and 0.16 degrees C for 76.8-85.7% of the time. The data presented indicate that transporting codling moths as adults and pupae from Canada to South Africa had little effect on moth emergence, longevity, and ability to mate, as assessed in the laboratory. These results provide support to the suggestion that the STT for codling moth in pome fruit production areas might be evaluated and implemented by the importation of irradiated moths from rearing facilities in a different country or hemisphere.

  12. A method of measuring airborne acidity: its application for the determination of acid content on long-distance transported particles and in drainage water from spruces

    Science.gov (United States)

    Cyrill Brosset

    1976-01-01

    The acid properties of particles have been investigated by means of measuring the content of mainly strong acid in leaching solutions of particle samples and in drain water from trees. The measurements are based on Gran's plot and on a study of its curvature.

  13. Robustness of Distance-to-Default

    DEFF Research Database (Denmark)

    Jessen, Cathrine; Lando, David

    2013-01-01

    . A notable exception is a model with stochastic volatility of assets. In this case both the ranking of firms and the estimated default probabilities using distance-to-default perform significantly worse. We therefore propose a volatility adjustment of the distance-to-default measure, that significantly...

  14. Motivation in Distance Leaming

    Directory of Open Access Journals (Sweden)

    Daniela Brečko

    1996-12-01

    Full Text Available It is estimated that motivation is one of the most important psychological functions making it possible for people to leam even in conditions that do not meet their needs. In distance learning, a form of autonomous learning, motivation is of outmost importance. When adopting this method in learning an individual has to stimulate himself and take learning decisions on his or her own. These specific characteristics of distance learning should be taken into account. This all different factors maintaining the motivation of partici­pants in distance learning are to be included. Moreover, motivation in distance learning can be stimulated with specific learning materials, clear instructions and guide-lines, an efficient feed back, personal contact between tutors and parti­cipants, stimulating learning letters, telephone calls, encouraging letters and through maintaining a positive relationship between tutor and participant.

  15. Real-Time Cosmology with Gaia: Developing the Theory to Use Extragalactic Proper Motions to Make Dynamical Cosmological Tests, to Measure Geometric Distances, and to Detect Primordial Gravitational Waves

    Science.gov (United States)

    Darling, Jeremy

    A new field of study, "real-time cosmology," is now possible. This involves observing a dynamic universe that can be seen to change over human timescales. Most cosmological observations are geometrical, using standard candles or rulers to measure the expansion history and curvature as light propagates through the universe. Real-time cosmological measurements are dynamical, revealing the changing geometry of the universe - thus often providing geometrical distances independent of the canonical cosmological distance ladder - and are typically orthogonal to customary cosmological tests. This field of inquiry is no longer far-fetched, and this proposal demonstrates using extant data that many types of measurement are now within a factor of a few of being detectable, but the theory will very soon lag the observational capabilities. The Gaia mission will provide astrometry and proper motions of roughly 100 microarcseconds per year for half a million quasars by the end of its 5-year mission, but the theory for how to employ these data for cosmological tests has not been established. This project will develop the theory, models, and methods needed to make optimal use of the Gaia extragalactic proper motion measurements and to make significant new cosmological tests, distance measurements, and mass measurements. Gaia data can provide rich cosmological tests that are nearly model-independent. This work will build the theoretical framework enabling Gaia to measure or constrain: (1) The real-time growth and recession of structures, providing mass and distance measurements, (2) Extragalactic parallax for a statistical sample and individual galaxies, thus providing geometric distances, (3) The primordial stochastic long-period gravitational wave background, which deflects quasar light in a quadrupolar proper motion pattern, and (4) Cosmic shear, rotation, bulk motion, and local voids that may manifest as an apparent acceleration attributed to dark energy. One can also test the

  16. Einstein at a distance

    Energy Technology Data Exchange (ETDEWEB)

    Lambourne, Robert [Department of Physics and Astronomy, Open University, Milton Keynes (United Kingdom)

    2005-11-01

    This paper examines the challenges and rewards that can arise when the teaching of Einsteinian physics has to be accomplished by means of distance education. The discussion is mainly based on experiences gathered over the past 35 years at the UK Open University, where special and general relativity, relativistic cosmology and other aspects of Einsteinian physics, have been taught at a variety of levels, and using a range of techniques, to students studying at a distance.

  17. Long distance quantum teleportation

    Science.gov (United States)

    Xia, Xiu-Xiu; Sun, Qi-Chao; Zhang, Qiang; Pan, Jian-Wei

    2018-01-01

    Quantum teleportation is a core protocol in quantum information science. Besides revealing the fascinating feature of quantum entanglement, quantum teleportation provides an ultimate way to distribute quantum state over extremely long distance, which is crucial for global quantum communication and future quantum networks. In this review, we focus on the long distance quantum teleportation experiments, especially those employing photonic qubits. From the viewpoint of real-world application, both the technical advantages and disadvantages of these experiments are discussed.

  18. Evaluation of white-to-white distance and anterior chamber depth measurements using the IOL Master, slit-lamp adapted optical coherence tomography and digital photographs in phakic eyes.

    Science.gov (United States)

    Wilczyński, Michał; Pośpiech-Zabierek, Aleksandra

    2015-01-01

    The accurate measurement of the anterior chamber internal diameter and depth is important in ophthalmic diagnosis and before some eye surgery procedures. The purpose of the study was to compare the white-to-white distance measurements performed using the IOL-Master and photography with internal anterior chamber diameter determined using slit lamp adapted optical coherence tomography in healthy eyes, and to compare anterior chamber depth measurements by IOL-Master and slit lamp adapted optical coherence tomography. The data were gathered prospectively from a non-randomized consecutive series of patients. The examined group consisted of 46 eyes of 39 patients. White-to-white was measured using IOL-Master and photographs of the eye were taken with a digital camera. Internal anterior chamber diameter was measured with slit-lamp adapted optical coherence tomography. Anterior chamber depth was measured using the IOL Master and slit-lamp adapted optical coherence tomography. Statistical analysis was performed using parametric tests. A Bland-Altman plot was drawn. White-to-white distance by the IOL Master was 11.8 +/- 0.40 mm, on photographs it was 11.29 +/- 0.58 mm and internal anterior chamber diameter by slit-lamp adapted optical coherence tomography was 11.34?0.54 mm. A significant difference was found between IOL-Master and slit-lamp adapted optical coherence tomography (pphotographs (pphotographs (p>0.05). All measurements were correlated (Spearman pphotographs. In order to obtain accurate measurements of the internal anterior chamber diameter and anterior chamber depth, a method involving direct visualization of intraocular structures should be used.

  19. Spatial structure of the plasma sheet boundary layer at distances greater than 180 RE as derived from energetic particle measurements on GEOTAIL

    Directory of Open Access Journals (Sweden)

    T. Yamamoto

    Full Text Available We have analyzed the onsets of energetic particle bursts detected by the ICS and STICS sensors of the EPIC instrument on board the GEOTAIL spacecraft in the deep magnetotail (i.e., at distances greater than 180 RE. Such bursts are commonly observed at the plasma-sheet boundary layer (PSBL and are highly collimated along the magnetic field. The bursts display a normal velocity dispersion (i.e., the higher-speed particles are seen first, while the progressively lower speed particles are seen later when observed upon entry of the spacecraft from the magnetotail lobes into the plasma sheet. Upon exit from the plasma sheet a reverse velocity dispersion is observed (i.e., lower-speed particles disappear first and higher-speed particles disappear last. Three major findings are as follows. First, the tailward-jetting energetic particle populations of the distant-tail plasma sheet display an energy layering: the energetic electrons stream along open PSBL field lines with peak fluxes at the lobes. Energetic protons occupy the next layer, and as the spacecraft moves towards the neutral sheet progressively decreasing energies are encountered systematically. These plasma-sheet layers display spatial symmetry, with the plane of symmetry the neutral sheet. Second, if we consider the same energy level of energetic particles, then the H+ layer is confined within that of the energetic electron, the He++ layer is confined within that of the proton, and the oxygen layer is confined within the alpha particle layer. Third, whenever the energetic electrons show higher fluxes inside the plasma sheet as compared to those at the boundary layer, their angular distribution is isotropic irrespective of the Earthward or tailward character of fluxes, suggesting a closed field line topology.

  20. Spatial structure of the plasma sheet boundary layer at distances greater than 180 RE as derived from energetic particle measurements on GEOTAIL

    Directory of Open Access Journals (Sweden)

    D. V. Sarafopoulos

    1997-10-01

    Full Text Available We have analyzed the onsets of energetic particle bursts detected by the ICS and STICS sensors of the EPIC instrument on board the GEOTAIL spacecraft in the deep magnetotail (i.e., at distances greater than 180 RE. Such bursts are commonly observed at the plasma-sheet boundary layer (PSBL and are highly collimated along the magnetic field. The bursts display a normal velocity dispersion (i.e., the higher-speed particles are seen first, while the progressively lower speed particles are seen later when observed upon entry of the spacecraft from the magnetotail lobes into the plasma sheet. Upon exit from the plasma sheet a reverse velocity dispersion is observed (i.e., lower-speed particles disappear first and higher-speed particles disappear last. Three major findings are as follows. First, the tailward-jetting energetic particle populations of the distant-tail plasma sheet display an energy layering: the energetic electrons stream along open PSBL field lines with peak fluxes at the lobes. Energetic protons occupy the next layer, and as the spacecraft moves towards the neutral sheet progressively decreasing energies are encountered systematically. These plasma-sheet layers display spatial symmetry, with the plane of symmetry the neutral sheet. Second, if we consider the same energy level of energetic particles, then the H+ layer is confined within that of the energetic electron, the He++ layer is confined within that of the proton, and the oxygen layer is confined within the alpha particle layer. Third, whenever the energetic electrons show higher fluxes inside the plasma sheet as compared to those at the boundary layer, their angular distribution is isotropic irrespective of the Earthward or tailward character of fluxes, suggesting a closed field line topology.

  1. Modern Geometric Methods of Distance Determination

    Science.gov (United States)

    Thévenin, Frédéric; Falanga, Maurizio; Kuo, Cheng Yu; Pietrzyński, Grzegorz; Yamaguchi, Masaki

    2017-11-01

    Building a 3D picture of the Universe at any distance is one of the major challenges in astronomy, from the nearby Solar System to distant Quasars and galaxies. This goal has forced astronomers to develop techniques to estimate or to measure the distance of point sources on the sky. While most distance estimates used since the beginning of the 20th century are based on our understanding of the physics of objects of the Universe: stars, galaxies, QSOs, the direct measures of distances are based on the geometric methods as developed in ancient Greece: the parallax, which has been applied to stars for the first time in the mid-19th century. In this review, different techniques of geometrical astrometry applied to various stellar and cosmological (Megamaser) objects are presented. They consist in parallax measurements from ground based equipment or from space missions, but also in the study of binary stars or, as we shall see, of binary systems in distant extragalactic sources using radio telescopes. The Gaia mission will be presented in the context of stellar physics and galactic structure, because this key space mission in astronomy will bring a breakthrough in our understanding of stars, galaxies and the Universe in their nature and evolution with time. Measuring the distance to a star is the starting point for an unbiased description of its physics and the estimate of its fundamental parameters like its age. Applying these studies to candles such as the Cepheids will impact our large distance studies and calibration of other candles. The text is constructed as follows: introducing the parallax concept and measurement, we shall present briefly the Gaia satellite which will be the future base catalogue of stellar astronomy in the near future. Cepheids will be discussed just after to demonstrate the state of the art in distance measurements in the Universe with these variable stars, with the objective of 1% of error in distances that could be applied to our closest

  2. Cepheids Geometrical Distances Using Space Interferometry

    Science.gov (United States)

    Marengo, M.; Karovska, M.; Sasselov, D. D.; Sanchez, M.

    2004-05-01

    A space based interferometer with a sub-milliarcsecond resolution in the UV-optical will provide a new avenue for the calibration of primary distance indicators with unprecedented accuracy, by allowing very accurate and stable measurements of Cepheids pulsation amplitudes at wavelengths not accessible from the ground. Sasselov & Karovska (1994) have shown that interferometers allow very accurate measurements of Cepheids distances by using a ``geometric'' variant of the Baade-Wesselink method. This method has been succesfully applied to derive distances and radii of nearby Cepheids using ground-based near-IR and optical interferometers, within a 15% accuracy level. Our study shows that the main source of error in these measurements is due to the perturbing effects of the Earth atmosphere, which is the limiting factor in the interferometer stability. A space interferometer will not suffer from this intrinsic limitations, and can potentially lead to improve astronomical distance measurements by an order of magnitude in precision. We discuss here the technical requirements that a space based facility will need to carry out this project, allowing distance measurements within a few percent accuracy level. We will finally discuss how a sub-milliarcsecond resolution will allow the direct distance determination for hundreds of galactic sources, and provide a substantial improvement in the zero-point of the Cepheid distance scale.

  3. Ethnical distance in Vojvodina: Research results

    Directory of Open Access Journals (Sweden)

    Lazar Žolt

    2005-01-01

    Full Text Available This article presents the results of the ethnical distance measuring in Vojvodina, the north Province of the Republic of Serbia. The measuring was carried out on autumn 2002, during realization of the wider project of multiculturalism research in the mentioned region. According to the results the ethnical distances in Vojvodina are quite equalized and they are grouped around the attitude "all the same". Vojvodinian Serbs are more favorable partners for the majority of social contacts, and the relatively largest distance is shown toward Roma. The ethnical distance results also discovers two very important factors for understanding the interethnic relations in Vojvodina: first, the "rational" kind of social contacts with the members of the other ethnical groups are more preferable for the majority of respondents, and second, they have very equal distances toward their own ethnical groups.

  4. The distances of the Galactic Novae

    Science.gov (United States)

    Ozdonmez, Aykut; Guver, Tolga; Cabrera-Lavers, Antonio; Ak, Tansel

    2016-07-01

    Using location of the RC stars on the CMDs obtained from the UKIDSS, VISTA and 2MASS photometry, we have derived the reddening-distance relations towards each Galactic nova for which at least one independent reddening measurement exists. We were able to determine the distances of 72 Galactic novae and set lower limits on the distances of 45 systems. The reddening curves of the systems are presented. These curves can be also used to estimate reddening or the distance of any source, whose location is close to the position of the nova in our sample. The distance measurement method in our study can be easily applicable to any source, especially for ones that concentrated along the Galactic plane.

  5. Characteristics of short distance field of a source radiating at electronic frequencies in a ionospheric plasma. Applications to density and electron temperature measurement by mutual impedance probe

    International Nuclear Information System (INIS)

    Debrie, R.

    1983-06-01

    Realization of a new type of radio-frequency probe, the mutual-impedance probe (or the quadrupole probe) is developed. Theoretical results obtained with a cold plasma description of the ionized medium with static magnetic field. Transfer impedance between two dipoles in an homogeneous hot and isotope plasma is then calculated. In equatorial ionosphere, measurements made by the H.F. quadrupole probe, in the Veronique rocket, during the Cisaspe experiment, have been interpreted with this hot plasma theory. The influence of a plasma drift with respect to the emitter dipole is analyzed. The influence of a static magnetic field in hot and homogeneous plasma, on the frequency response curve of the mutual impedance is studied. For, in ionospheric plasmas of auroral and polar zones, the earth magnetic field is no more negligible and gives to the plasma dielectric, strongly anisotropic, properties well described by the microscopic theory in hot magnetoplasma. The space time fast evolution of characteristics of plasma encountered in space experiments has been shown up with a new method of measurement the self-oscillating quadrupole probe. The work synthesis is put in a concrete form on the polar satellite Aureol-3 the first results of which are presented. This satellite allows a precise study of ionosphere auroral zones. At last, it is shown that methods developed for electron density and temperature measurements can be transposed in low frequency. In this case, measurements with quadrupole probe allow to get the ion average mass by lower hybrid frequency excitation [fr

  6. Recoil distance method lifetime measurements of the 2⁺₁ excited states in ⁸⁴Kr and ⁹⁴Sr

    OpenAIRE

    Chester, Aaron Stuart

    2017-01-01

    Intense re-accelerated beams delivered by the Isotope Separator and Accelerator (ISAC-II) facility at TRIUMF, Canada’s national laboratory for particle and nuclear physics, permit access to nuclear structure information for a wide range of radionuclides via in-beam γ-ray spectroscopy with the TRIUMF-ISAC Gamma-Ray Escape Suppressed Spectrometer (TIGRESS), a high-efficiency and Compton-suppressed segmented high-purity germanium (HPGe) detector array. Electromagnetic transition rates measured v...

  7. Managerial Distance and Virtual Ownership

    DEFF Research Database (Denmark)

    Hansmann, Henry; Thomsen, Steen

    Industrial foundations are autonomous nonprofit entities that own and control one or more conventional business firms. These foundations are common in Northern Europe, where they own a number of internationally prominent companies. Previous studies have indicated, surprisingly, that companies con......, but corporate governance and fiduciary behavior more generally....... on differences among the industrial foundations themselves. We work with a rich data set comprising 113 foundation-owned Danish companies over the period 2003-2008. We focus in particular on a composite structural factor that we term “managerial distance.” We propose this as a measure of the extent to which......-seeking outside owners of the company. Consistent with this hypothesis, our empirical analysis shows a positive, significant, and robust association between managerial distance and the economic performance of foundation owned companies. The findings appear to illuminate not just foundation governance...

  8. Determining distances using asteroseismic methods

    DEFF Research Database (Denmark)

    Aguirre, Victor Silva; Casagrande, L.; Basu, Sarbina

    2013-01-01

    Asteroseismology has been extremely successful in determining the properties of stars in different evolutionary stages with a remarkable level of precision. However, to fully exploit its potential, robust methods for estimating stellar parameters are required and independent verification of the r......Asteroseismology has been extremely successful in determining the properties of stars in different evolutionary stages with a remarkable level of precision. However, to fully exploit its potential, robust methods for estimating stellar parameters are required and independent verification...... fluxes, and thus distances for field stars in a self-consistent manner. Applying our method to a sample of solar-like oscillators in the {\\it Kepler} field that have accurate {\\it Hipparcos} parallaxes, we find agreement in our distance determinations to better than 5%. Comparison with measurements...

  9. Distance Teaching on Bornholm

    DEFF Research Database (Denmark)

    Hansen, Finn J. S.; Clausen, Christian

    2001-01-01

    The case study represents an example of a top-down introduction of distance teaching as part of Danish trials with the introduction of multimedia in education. The study is concerned with the background, aim and context of the trial as well as the role and working of the technology and the organi......The case study represents an example of a top-down introduction of distance teaching as part of Danish trials with the introduction of multimedia in education. The study is concerned with the background, aim and context of the trial as well as the role and working of the technology...

  10. Reliability of reference distances used in photogrammetry.

    Science.gov (United States)

    Aksu, Muge; Kaya, Demet; Kocadereli, Ilken

    2010-07-01

    To determine the reliability of the reference distances used for photogrammetric assessment. The sample consisted of 100 subjects with mean ages of 22.97 +/- 2.98 years. Five lateral and four frontal parameters were measured directly on the subjects' faces. For photogrammetric assessment, two reference distances for the profile view and three reference distances for the frontal view were established. Standardized photographs were taken and all the parameters that had been measured directly on the face were measured on the photographs. The reliability of the reference distances was checked by comparing direct and indirect values of the parameters obtained from the subjects' faces and photographs. Repeated measure analysis of variance (ANOVA) and Bland-Altman analyses were used for statistical assessment. For profile measurements, the indirect values measured were statistically different from the direct values except for Sn-Sto in male subjects and Prn-Sn and Sn-Sto in female subjects. The indirect values of Prn-Sn and Sn-Sto were reliable in both sexes. The poorest results were obtained in the indirect values of the N-Sn parameter for female subjects and the Sn-Me parameter for male subjects according to the Sa-Sba reference distance. For frontal measurements, the indirect values were statistically different from the direct values in both sexes except for one in male subjects. The indirect values measured were not statistically different from the direct values for Go-Go. The indirect values of Ch-Ch were reliable in male subjects. The poorest results were obtained according to the P-P reference distance. For profile assessment, the T-Ex reference distance was reliable for Prn-Sn and Sn-Sto in both sexes. For frontal assessment, Ex-Ex and En-En reference distances were reliable for Ch-Ch in male subjects.

  11. The birth canal: correlation between the pubic arch angle, the interspinous diameter, and the obstetrical conjugate: a computed tomography biometric study in reproductive age women.

    Science.gov (United States)

    Perlman, Sharon; Raviv-Zilka, Lisa; Levinsky, Denis; Gidron, Ayelet; Achiron, Reuven; Gilboa, Yinon; Kivilevitch, Zvi

    2018-04-22

    Assessment of pelvic configuration is an important factor in the prediction of a successful vaginal birth. However, manual evaluation of the pelvis is practically a vanishing art, and imaging techniques are not available as a real-time bed-side tool. Unlike the obstetrical conjugate diameter (OC) and inter spinous diameter (ISD), the pubic arch angle (PAA) can be easily measured by transperineal ultrasound. Three-dimensional computed tomography bone reconstructions were used to measure the three main birth canal diameters, evaluate the correlation between them, and establish the normal reference range for the inlet, mid-, and pelvic outlet. Measurements of the PAA, obstetric conjugate (OC), and ISD were performed offline using three-dimensional post processing reconstruction in bone algorithm application of the pelvis on examinations performed for suspected renal colic in nonpregnant reproductive age woman. The mean of two measurements was used for statistical analysis which included reproducibility of measurements, regression curve estimation between PAA, OC, and ISD, and calculation of the respective reference range centiles for each PAA degree. Two hundred ninety-eight women comprised the study group. The mean ± SD of the PAA, ISD, and OC were 104.9° (±7.4), 103.8 mm (±7.3), and 129.9 mm (±8.3), respectively. The intra- and interobserver agreement defined by the intraclass correlation coefficient (ICC) was excellent for all parameters (range 0.905-0.993). A significant positive correlation was found between PAA and ISD and between PAA and OCD (Pearson's correlation = 0.373 (p correlation between the three pelvic landmarks with greatest impact on the prediction of a successful vaginal delivery: the PAA which is easily measured sonographically and the ISD and OC which are not measurable by ultrasound. This correlation may serve as a basis for future studies to assess its utility and prognostic value for a safe vaginal delivery.

  12. Theoretical Principles of Distance Education.

    Science.gov (United States)

    Keegan, Desmond, Ed.

    This book contains the following papers examining the didactic, academic, analytic, philosophical, and technological underpinnings of distance education: "Introduction"; "Quality and Access in Distance Education: Theoretical Considerations" (D. Randy Garrison); "Theory of Transactional Distance" (Michael G. Moore);…

  13. Censoring distances based on labeled cortical distance maps in cortical morphometry.

    Science.gov (United States)

    Ceyhan, Elvan; Nishino, Tomoyuki; Alexopolous, Dimitrios; Todd, Richard D; Botteron, Kelly N; Miller, Michael I; Ratnanather, J Tilak

    2013-01-01

    It has been demonstrated that shape differences in cortical structures may be manifested in neuropsychiatric disorders. Such morphometric differences can be measured by labeled cortical distance mapping (LCDM) which characterizes the morphometry of the laminar cortical mantle of cortical structures. LCDM data consist of signed/labeled distances of gray matter (GM) voxels with respect to GM/white matter (WM) surface. Volumes and other summary measures for each subject and the pooled distances can help determine the morphometric differences between diagnostic groups, however they do not reveal all the morphometric information contained in LCDM distances. To extract more information from LCDM data, censoring of the pooled distances is introduced for each diagnostic group where the range of LCDM distances is partitioned at a fixed increment size; and at each censoring step, the distances not exceeding the censoring distance are kept. Censored LCDM distances inherit the advantages of the pooled distances but also provide information about the location of morphometric differences which cannot be obtained from the pooled distances. However, at each step, the censored distances aggregate, which might confound the results. The influence of data aggregation is investigated with an extensive Monte Carlo simulation analysis and it is demonstrated that this influence is negligible. As an illustrative example, GM of ventral medial prefrontal cortices (VMPFCs) of subjects with major depressive disorder (MDD), subjects at high risk (HR) of MDD, and healthy control (Ctrl) subjects are used. A significant reduction in laminar thickness of the VMPFC in MDD and HR subjects is observed compared to Ctrl subjects. Moreover, the GM LCDM distances (i.e., locations with respect to the GM/WM surface) for which these differences start to occur are determined. The methodology is also applicable to LCDM-based morphometric measures of other cortical structures affected by disease.

  14. Censoring Distances Based on Labeled Cortical Distance Maps in Cortical Morphometry

    Directory of Open Access Journals (Sweden)

    Elvan eCeyhan

    2013-10-01

    Full Text Available It has been demonstrated that shape differences are manifested in cortical structures due to neuropsychiatric disorders. Such morphometric differences can be measured by labeled cortical distance mapping (LCDM which characterizes the morphometry of the laminar cortical mantle of cortical structures. LCDM data consist of signed/labeled distances of gray matter (GM voxels with respect to GM/white matter (WM surface. Volumes and other summary measures for each subject and the pooled distances can help determine the morphometric differences between diagnostic groups, however they do not reveal all the morphometric information con-tained in LCDM distances. To extract more information from LCDM data, censoring of the pooled distances is introduced for each diagnostic group where the range of LCDM distances is partitioned at a fixed increment size; and at each censoring step, the distances not exceeding the censoring distance are kept. Censored LCDM distances inherit the advantages of the pooled distances but also provide information about the location of morphometric differences which cannot be obtained from the pooled distances. However, at each step, the censored distances aggregate, which might confound the results. The influence of data aggregation is investigated with an extensive Monte Carlo simulation analysis and it is demonstrated that this influence is negligible. As an illustrative example, GM of ventral medial prefrontal cortices (VMPFCs of subjects with major depressive disorder (MDD, subjects at high risk (HR of MDD, and healthy control (Ctrl subjects are used. A significant reduction in laminar thickness of the VMPFC in MDD and HR subjects is observed compared to Ctrl subjects. Moreover, the GM LCDM distances (i.e., locations with respect to the GM/WM surface for which these differences start to occur are determined. The methodology is also applicable to LCDM-based morphometric measures of other cortical structures affected by disease.

  15. Inland Waters - Navigation Distance Mark - Minnesota River (Non-Navigable)

    Data.gov (United States)

    Army Corps of Engineers, Department of the Army, Department of Defense — A distance mark indicates the distance measured from an origin and consists of a distinct location without special installation, used to serve as a reference along...

  16. Planning with Reachable Distances

    KAUST Repository

    Tang, Xinyu; Thomas, Shawna; Amato, Nancy M.

    2009-01-01

    reachable distance space (RD-space), in which all configurations lie in the set of constraint-satisfying subspaces. This enables us to directly sample the constrained subspaces with complexity linear in the robot's number of degrees of freedom. In addition

  17. De-severing distance

    DEFF Research Database (Denmark)

    Jensen, Hanne Louise; de Neergaard, Maja

    2016-01-01

    De-severing Distance This paper draws on the growing body of mobility literature that shows how mobility can be viewed as meaningful everyday practices (Freudendal –Pedersen 2007, Cresswell 2006) this paper examines how Heidegger’s term de-severing can help us understand the everyday coping with ...

  18. The Euclidean distance degree

    NARCIS (Netherlands)

    Draisma, J.; Horobet, E.; Ottaviani, G.; Sturmfels, B.; Thomas, R.R.; Zhi, L.; Watt, M.

    2014-01-01

    The nearest point map of a real algebraic variety with respect to Euclidean distance is an algebraic function. For instance, for varieties of low rank matrices, the Eckart-Young Theorem states that this map is given by the singular value decomposition. This article develops a theory of such nearest

  19. Determining average yarding distance.

    Science.gov (United States)

    Roger H. Twito; Charles N. Mann

    1979-01-01

    Emphasis on environmental and esthetic quality in timber harvesting has brought about increased use of complex boundaries of cutting units and a consequent need for a rapid and accurate method of determining the average yarding distance and area of these units. These values, needed for evaluation of road and landing locations in planning timber harvests, are easily and...

  20. Prospect of Distance Learning

    Science.gov (United States)

    Rahman, Monsurur; Karim, Reza; Byramjee, Framarz

    2015-01-01

    Many educational institutions in the United States are currently offering programs through distance learning, and that trend is rising. In almost all spheres of education a developing country like Bangladesh needs to make available the expertise of the most qualified faculty to her distant people. But the fundamental question remains as to whether…

  1. 80537 based distance relay

    DEFF Research Database (Denmark)

    Pedersen, Knud Ole Helgesen

    1999-01-01

    A method for implementing a digital distance relay in the power system is described.Instructions are given on how to program this relay on a 80537 based microcomputer system.The problem is used as a practical case study in the course 53113: Micocomputer applications in the power system.The relay...

  2. MARBLE (Multiple Antenna Radio-interferometry for Baseline Length Evaluation): Development of a Compact VLBI System for Calibrating GNSS and Electronic Distance Measurement Devices

    Science.gov (United States)

    Ichikawa, R.; Ishii, A.; Takiguchi, H.; Kimura, M.; Sekido, M.; Takefuji, K.; Ujihara, H.; Hanado, Y.; Koyama, Y.; Kondo, T.; Kurihara, S.; Kokado, K.; Kawabata, R.; Nozawa, K.; Mukai, Y.; Kuroda, J.; Ishihara, M.; Matsuzaka, S.

    2012-12-01

    We are developing a compact VLBI system with a 1.6-m diameter aperture dish in order to provide reference baseline lengths for calibration. The reference baselines are used to validate surveying instruments such as GPS and EDM and is maintained by the Geospatial Information Authority of Japan (GSI). The compact VLBI system will be installed at both ends of the reference baseline. Since the system is not sensitive enough to detect fringes between the two small dishes, we have designed a new observation concept including one large dish station. We can detect two group delays between each compact VLBI system and the large dish station based on conventional VLBI measurement. A group delay between the two compact dishes can be indirectly calculated using a simple equation. We named the idea "Multiple Antenna Radio-interferometry for Baseline Length Evaluation", or MARBLE system. The compact VLBI system is easy transportable and consists of the compact dish, a new wide-band front-end system, azimuth and elevation drive units, an IF down-converter unit, an antenna control unit (ACU), a counterweight, and a monument pillar. Each drive unit is equipped with a zero-backlash harmonic drive gearing component. A monument pillar is designed to mount typical geodetic GNSS antennas easily and an offset between the GNSS antenna reference point. The location of the azimuth-elevation crossing point of the VLBI system is precisely determined with an uncertainty of less than 0.2 mm. We have carried out seven geodetic VLBI experiments on the Kashima-Tsukuba baseline (about 54 km) using the two prototypes of the compact VLBI system between December 2009 and December 2010. The average baseline length and repeatability of the experiments is 54184874.0 ± 2.4 mm. The results are well consistent with those obtained by GPS measurements. In addition, we are now planning to use the compact VLBI system for precise time and frequency comparison between separated locations.

  3. Handwriting individualization using distance and rarity

    Science.gov (United States)

    Tang, Yi; Srihari, Sargur; Srinivasan, Harish

    2012-01-01

    Forensic individualization is the task of associating observed evidence with a specific source. The likelihood ratio (LR) is a quantitative measure that expresses the degree of uncertainty in individualization, where the numerator represents the likelihood that the evidence corresponds to the known and the denominator the likelihood that it does not correspond to the known. Since the number of parameters needed to compute the LR is exponential with the number of feature measurements, a commonly used simplification is the use of likelihoods based on distance (or similarity) given the two alternative hypotheses. This paper proposes an intermediate method which decomposes the LR as the product of two factors, one based on distance and the other on rarity. It was evaluated using a data set of handwriting samples, by determining whether two writing samples were written by the same/different writer(s). The accuracy of the distance and rarity method, as measured by error rates, is significantly better than the distance method.

  4. Distance to Cure

    OpenAIRE

    Capachi, Casey

    2013-01-01

    Distance to Cure A three-part television series by Casey Capachi www.distancetocure.com   Abstract   How far would you go for health care? This three-part television series, featuring two introductory segments between each piece, focuses on the physical, cultural, and political obstacles facing rural Native American patients and the potential of health technology to break down those barriers to care.   Part one,Telemedici...

  5. The transposition distance for phylogenetic trees

    OpenAIRE

    Rossello, Francesc; Valiente, Gabriel

    2006-01-01

    The search for similarity and dissimilarity measures on phylogenetic trees has been motivated by the computation of consensus trees, the search by similarity in phylogenetic databases, and the assessment of clustering results in bioinformatics. The transposition distance for fully resolved phylogenetic trees is a recent addition to the extensive collection of available metrics for comparing phylogenetic trees. In this paper, we generalize the transposition distance from fully resolved to arbi...

  6. Absolute Distance Measurements with Tunable Semiconductor Laser

    Czech Academy of Sciences Publication Activity Database

    Mikel, Břetislav; Číp, Ondřej; Lazar, Josef

    T118, - (2005), s. 41-44 ISSN 0031-8949 R&D Projects: GA AV ČR(CZ) IAB2065001 Keywords : tunable laser * absolute interferometer Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.661, year: 2004

  7. Fidelity induced distance measures for quantum states

    International Nuclear Information System (INIS)

    Ma Zhihao; Zhang Fulin; Chen Jingling

    2009-01-01

    Fidelity plays an important role in quantum information theory. In this Letter, we introduce new metric of quantum states induced by fidelity, and connect it with the well-known trace metric, Sine metric and Bures metric for the qubit case. The metric character is also presented for the qudit (i.e., d-dimensional system) case. The CPT contractive property and joint convex property of the metric are also studied.

  8. Relativistic distances, sizes, lengths

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1992-01-01

    Such notion as light or retarded distance, field size, formation way, visible size of a body, relativistic or radar length and wave length of light from a moving atom are considered. The relation between these notions is cleared up, their classification is given. It is stressed that the formation way is defined by the field size of a moving particle. In the case of the electromagnetic field, longitudinal sizes increase proportionally γ 2 with growing charge velocity (γ is the Lorentz-factor). 18 refs

  9. Distance Metric Tracking

    Science.gov (United States)

    2016-03-02

    whereBψ is any Bregman divergence and ηt is the learning rate parameter. From (Hall & Willett, 2015) we have: Theorem 1. G` = max θ∈Θ,`∈L ‖∇f(θ)‖ φmax = 1...Kullback-Liebler divergence between an initial guess of the matrix that parameterizes the Mahalanobis distance and a solution that satisfies a set of...Bregman divergence and ηt is the learning rate parameter. M̂0, µ̂0 are initialized to some initial value. In [18] a closed-form algorithm for solving

  10. PERBANDINGAN EUCLIDEAN DISTANCE DENGAN CANBERRA DISTANCE PADA FACE RECOGNITION

    Directory of Open Access Journals (Sweden)

    Sendhy Rachmat Wurdianarto

    2014-08-01

    Full Text Available Perkembangan ilmu pada dunia komputer sangatlah pesat. Salah satu yang menandai hal ini adalah ilmu komputer telah merambah pada dunia biometrik. Arti biometrik sendiri adalah karakter-karakter manusia yang dapat digunakan untuk membedakan antara orang yang satu dengan yang lainnya. Salah satu pemanfaatan karakter / organ tubuh pada setiap manusia yang digunakan untuk identifikasi (pengenalan adalah dengan memanfaatkan wajah. Dari permasalahan diatas dalam pengenalan lebih tentang aplikasi Matlab pada Face Recognation menggunakan metode Euclidean Distance dan Canberra Distance. Model pengembangan aplikasi yang digunakan adalah model waterfall. Model waterfall beriisi rangkaian aktivitas proses yang disajikan dalam proses analisa kebutuhan, desain menggunakan UML (Unified Modeling Language, inputan objek gambar diproses menggunakan Euclidean Distance dan Canberra Distance. Kesimpulan yang dapat ditarik adalah aplikasi face Recognation menggunakan metode euclidean Distance dan Canverra Distance terdapat kelebihan dan kekurangan masing-masing. Untuk kedepannya aplikasi tersebut dapat dikembangkan dengan menggunakan objek berupa video ataupun objek lainnya.   Kata kunci : Euclidean Distance, Face Recognition, Biometrik, Canberra Distance

  11. Distance collaborations with industry

    Energy Technology Data Exchange (ETDEWEB)

    Peskin, A.; Swyler, K.

    1998-06-01

    The college industry relationship has been identified as a key policy issue in Engineering Education. Collaborations between academic institutions and the industrial sector have a long history and a bright future. For Engineering and Engineering Technology programs in particular, industry has played a crucial role in many areas including advisement, financial support, and practical training of both faculty and students. Among the most important and intimate interactions are collaborative projects and formal cooperative education arrangements. Most recently, such collaborations have taken on a new dimension, as advances in technology have made possible meaningful technical collaboration at a distance. There are several obvious technology areas that have contributed significantly to this trend. Foremost is the ubiquitous presence of the Internet. Perhaps almost as important are advances in computer based imaging. Because visual images offer a compelling user experience, it affords greater knowledge transfer efficiency than other modes of delivery. Furthermore, the quality of the image appears to have a strongly correlated effect on insight. A good visualization facility offers both a means for communication and a shared information space for the subjects, which are among the essential features of both peer collaboration and distance learning.

  12. Interactive Distance Learning in Connecticut.

    Science.gov (United States)

    Pietras, Jesse John; Murphy, Robert J.

    This paper provides an overview of distance learning activities in Connecticut and addresses the feasibility of such activities. Distance education programs have evolved from the one dimensional electronic mail systems to the use of sophisticated digital fiber networks. The Middlesex Distance Learning Consortium has developed a long-range plan to…

  13. Distance to VY Canis Majoris with VERA

    OpenAIRE

    Choi, Yoon Kyung; Hirota, Tomoya; Honma, Mareki; Kobayashi, Hideyuki; Bushimata, Takeshi; Imai, Hiroshi; Iwadate, Kenzaburo; Jike, Takaaki; Kameno, Seiji; Kameya, Osamu; Kamohara, Ryuichi; Kan-ya, Yukitoshi; Kawaguchi, Noriyuki; Kijima, Masachika; Kim, Mi Kyoung

    2008-01-01

    We report astrometric observations of H2O masers around the red supergiant VY Canis Majoris (VY CMa) carried out with VLBI Exploration of Radio Astrometry (VERA). Based on astrometric monitoring for 13 months, we successfully measured a trigonometric parallax of 0.88 +/- 0.08 mas, corresponding to a distance of 1.14 +0.11/-0.09 kpc. This is the most accurate distance to VY CMa and the first one based on an annual parallax measurement. The luminosity of VY CMa has been overestimated due to a p...

  14. Distances on Cosmological Scales with VLTI

    OpenAIRE

    Karovska, Margarita; Elvis, Martin; Marengo, Massimo

    2003-01-01

    We present here a new method using interferometric measurements of quasars, that allows the determination of direct geometrical distances on cosmic scales. Quasar Broad Emission Line Regions sizes provide a "meter rule" with which to measure the metric of the Universe. This method is less dependent of model assumptions, and even of variations in the fundamental constants (other than c). We discuss the spectral and spatial requirements on the VLTI observations needed to carry out these measure...

  15. Planning with Reachable Distances

    KAUST Repository

    Tang, Xinyu

    2009-01-01

    Motion planning for spatially constrained robots is difficult due to additional constraints placed on the robot, such as closure constraints for closed chains or requirements on end effector placement for articulated linkages. It is usually computationally too expensive to apply sampling-based planners to these problems since it is difficult to generate valid configurations. We overcome this challenge by redefining the robot\\'s degrees of freedom and constraints into a new set of parameters, called reachable distance space (RD-space), in which all configurations lie in the set of constraint-satisfying subspaces. This enables us to directly sample the constrained subspaces with complexity linear in the robot\\'s number of degrees of freedom. In addition to supporting efficient sampling, we show that the RD-space formulation naturally supports planning, and in particular, we design a local planner suitable for use by sampling-based planners. We demonstrate the effectiveness and efficiency of our approach for several systems including closed chain planning with multiple loops, restricted end effector sampling, and on-line planning for drawing/sculpting. We can sample single-loop closed chain systems with 1000 links in time comparable to open chain sampling, and we can generate samples for 1000-link multi-loop systems of varying topology in less than a second. © 2009 Springer-Verlag.

  16. Research of the stopping distance for different road conditions

    Directory of Open Access Journals (Sweden)

    Daniel LYUBENOV

    2011-01-01

    Full Text Available In this paper a modern method for determination of stopping distance is represented. Application of the non-contact VBOX 3i 100Hz GPS Data Logger speed and distance measurement system is represented. A description of the total stopping distance of vehicle main components - driver reaction time, vehicle reaction time and vehicle braking capability has been made. Research of the total stopping distance of a vehicle for different road conditions has been made. The results for the stopping distance can be very useful in the expert practice.

  17. Characterizing the round sphere by mean distance

    DEFF Research Database (Denmark)

    Kokkendorff, Simon Lyngby

    2008-01-01

    We discuss the measure theoretic metric invariants extent, rendezvous number and mean distance of a general compact metric space X and relate these to classical metric invariants such as diameter and radius. In the final section we focus attention to the category of Riemannian manifolds. The main...

  18. Distance Matters: Physical Space and Social Impact.

    Science.gov (United States)

    Latane, Bibb; And Others

    1995-01-01

    Studies of college students and citizens of south Florida, United States, students in Shanghai, China, and an international sample of social psychologists show that social influence, measured by the frequency of memorable interactions, is heavily determined by distance. Confirms one principle from Latane's 1981 theory of social impact. (JBJ)

  19. Robustness of Distance-to-Default

    DEFF Research Database (Denmark)

    Jessen, Cathrine; Lando, David

    2015-01-01

    Distance-to-default (DD) is a measure of default risk derived from observed stock prices and book leverage using the structural credit risk model of Merton (1974). Despite the simplifying assumptions that underlie its derivation, DD has proven empirically to be a strong predictor of default. We use...

  20. Markov chain of distances between parked cars

    International Nuclear Information System (INIS)

    Seba, Petr

    2008-01-01

    We describe the distribution of distances between parked cars as a solution of certain Markov processes and show that its solution is obtained with the help of a distributional fixed point equation. Under certain conditions the process is solved explicitly. The resulting probability density is compared with the actual parking data measured in the city. (fast track communication)

  1. Safety distance between underground natural gas and water pipeline facilities

    International Nuclear Information System (INIS)

    Mohsin, R.; Majid, Z.A.; Yusof, M.Z.

    2014-01-01

    A leaking water pipe bursting high pressure water jet in the soil will create slurry erosion which will eventually erode the adjacent natural gas pipe, thus causing its failure. The standard 300 mm safety distance used to place natural gas pipe away from water pipeline facilities needs to be reviewed to consider accidental damage and provide safety cushion to the natural gas pipe. This paper presents a study on underground natural gas pipeline safety distance via experimental and numerical approaches. The pressure–distance characteristic curve obtained from this experimental study showed that the pressure was inversely proportional to the square of the separation distance. Experimental testing using water-to-water pipeline system environment was used to represent the worst case environment, and could be used as a guide to estimate appropriate safety distance. Dynamic pressures obtained from the experimental measurement and simulation prediction mutually agreed along the high-pressure water jetting path. From the experimental and simulation exercises, zero effect distance for water-to-water medium was obtained at an estimated horizontal distance at a minimum of 1500 mm, while for the water-to-sand medium, the distance was estimated at a minimum of 1200 mm. - Highlights: • Safe separation distance of underground natural gas pipes was determined. • Pressure curve is inversely proportional to separation distance. • Water-to-water system represents the worst case environment. • Measured dynamic pressures mutually agreed with simulation results. • Safe separation distance of more than 1200 mm should be applied

  2. Are contemporary tourists consuming distance?

    DEFF Research Database (Denmark)

    Larsen, Gunvor Riber

    2012. Background The background for this research, which explores how tourists represent distance and whether or not distance can be said to be consumed by contemporary tourists, is the increasing leisure mobility of people. Travelling for the purpose of visiting friends and relatives is increasing...... of understanding mobility at a conceptual level, and distance matters to people's manifest mobility: how they travel and how far they travel are central elements of their movements. Therefore leisure mobility (indeed all mobility) is the activity of relating across distance, either through actual corporeal...... metric representation. These representations are the focus for this research. Research Aim and Questions The aim of this research is thus to explore how distance is being represented within the context of leisure mobility. Further the aim is to explore how or whether distance is being consumed...

  3. Measuring $\

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Jessica Sarah [Univ. of Cambridge (United Kingdom)

    2011-01-01

    The MINOS Experiment consists of two steel-scintillator calorimeters, sampling the long baseline NuMI muon neutrino beam. It was designed to make a precise measurement of the ‘atmospheric’ neutrino mixing parameters, Δm2 atm. and sin2 (2 atm.). The Near Detector measures the initial spectrum of the neutrino beam 1km from the production target, and the Far Detector, at a distance of 735 km, measures the impact of oscillations in the neutrino energy spectrum. Work performed to validate the quality of the data collected by the Near Detector is presented as part of this thesis. This thesis primarily details the results of a vμ disappearance analysis, and presents a new sophisticated fitting software framework, which employs a maximum likelihood method to extract the best fit oscillation parameters. The software is entirely decoupled from the extrapolation procedure between the detectors, and is capable of fitting multiple event samples (defined by the selections applied) in parallel, and any combination of energy dependent and independent sources of systematic error. Two techniques to improve the sensitivity of the oscillation measurement were also developed. The inclusion of information on the energy resolution of the neutrino events results in a significant improvement in the allowed region for the oscillation parameters. The degree to which sin2 (2θ )= 1.0 could be disfavoured with the exposure of the current dataset if the true mixing angle was non-maximal, was also investigated, with an improved neutrino energy reconstruction for very low energy events. The best fit oscillation parameters, obtained by the fitting software and incorporating resolution information were: | Δm2| = 2.32+0.12 -0.08×10-3 eV2 and sin2 (2θ ) > 0.90(90% C.L.). The analysis provides the current world best measurement of the atmospheric neutrino mass

  4. Distance : between deixis and perspectivity

    OpenAIRE

    Meermann, Anastasia; Sonnenhauser, Barbara

    2015-01-01

    Discussing exemplary applications of the notion of distance in linguistic analysis, this paper shows that very different phenomena are described in terms of this concept. It is argued that in order to overcome the problems arising from this mixup, deixis, distance and perspectivity have to be distinguished and their interrelations need to be described. Thereby, distance emerges as part of a recursive process mediating between situation-bound deixis and discourse-level perspectivity. This is i...

  5. The distance from CERN to LNGS

    CERN Document Server

    Jones, M; Crespi, M; Colosimo, G; Mazzoni, A; Durand, S

    2012-01-01

    The calculation of the distance from CERN to Gran Sasso involves the combination of three independent sets of measurements: the calculation of the distance between pillars included in the geodetic reference network at CERN and the Lab Nationale Gran Sasso (LNGS); and the transfer on each site of coordinates, from the geodetic surface network, underground into the tunnel or experiment hall installations. The transfer of coordinates, from the surface, underground at the two sites was not done as part of the CNGS Project. Initial survey concerns for the project were directed towards the orientation of the beamline from CERN to LNGS to within ~100 m. Gyro-theodolite measurements underground were planned at CERN so a transfer would effectively only translate the target point. Given the precision estimated for previous transfers, it was decided not to undertake expensive and time-consuming measurements campaigns for a negligible gain in accuracy. Therefore only GPS measurements at the two sites were carried out. Th...

  6. Effectiveness of Distance Learning for the Battle Staff NCO Course

    National Research Council Canada - National Science Library

    Drenth, Debra

    2001-01-01

    .... Unlike previous evaluations of distance learning, the measures used to compare groups were not students' immediate reactions to the course nor their end-of-course test scores but measures delayed...

  7. Distance criterion for hydrogen bond

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Distance criterion for hydrogen bond. In a D-H ...A contact, the D...A distance must be less than the sum of van der Waals Radii of the D and A atoms, for it to be a hydrogen bond.

  8. Social Distance and Intergenerational Relations

    Science.gov (United States)

    Kidwell, I. Jane; Booth, Alan

    1977-01-01

    Questionnaires were administered to a sample of adults to assess the extent of social distance between people of different ages. The findings suggest that the greater the age difference (younger or older) between people, the greater the social distance they feel. (Author)

  9. Quality Content in Distance Education

    Science.gov (United States)

    Yildiz, Ezgi Pelin; Isman, Aytekin

    2016-01-01

    In parallel with technological advances in today's world of education activities can be conducted without the constraints of time and space. One of the most important of these activities is distance education. The success of the distance education is possible with content quality. The proliferation of e-learning environment has brought a need for…

  10. Virtual Bioinformatics Distance Learning Suite

    Science.gov (United States)

    Tolvanen, Martti; Vihinen, Mauno

    2004-01-01

    Distance learning as a computer-aided concept allows students to take courses from anywhere at any time. In bioinformatics, computers are needed to collect, store, process, and analyze massive amounts of biological and biomedical data. We have applied the concept of distance learning in virtual bioinformatics to provide university course material…

  11. The Psychology of Psychic Distance

    DEFF Research Database (Denmark)

    Håkanson, Lars; Ambos, Björn; Schuster, Anja

    2016-01-01

    and their theoretical underpinnings assume psychic distances to be symmetric. Building on insights from psychology and sociology, this paper demonstrates how national factors and cognitive processes interact in the formation of asymmetric distance perceptions. The results suggest that exposure to other countries...

  12. Cognitive Styles and Distance Education.

    Science.gov (United States)

    Liu, Yuliang; Ginther, Dean

    1999-01-01

    Considers how to adapt the design of distance education to students' cognitive styles. Discusses cognitive styles, including field dependence versus independence, holistic-analytic, sensory preference, hemispheric preferences, and Kolb's Learning Style Model; and the characteristics of distance education, including technology. (Contains 92…

  13. Distance Learning: Practice and Dilemmas

    Science.gov (United States)

    Tatkovic, Nevenka; Sehanovic, Jusuf; Ruzic, Maja

    2006-01-01

    In accordance with the European processes of integrated and homogeneous education, the paper presents the essential viewpoints and questions covering the establishment and development of "distance learning" (DL) in Republic of Croatia. It starts from the advantages of distance learning versus traditional education taking into account…

  14. A VLBI resolution of the Pleiades distance controversy.

    Science.gov (United States)

    Melis, Carl; Reid, Mark J; Mioduszewski, Amy J; Stauffer, John R; Bower, Geoffrey C

    2014-08-29

    Because of its proximity and its youth, the Pleiades open cluster of stars has been extensively studied and serves as a cornerstone for our understanding of the physical properties of young stars. This role is called into question by the "Pleiades distance controversy," wherein the cluster distance of 120.2 ± 1.5 parsecs (pc) as measured by the optical space astrometry mission Hipparcos is significantly different from the distance of 133.5 ± 1.2 pc derived with other techniques. We present an absolute trigonometric parallax distance measurement to the Pleiades cluster that uses very long baseline radio interferometry (VLBI). This distance of 136.2 ± 1.2 pc is the most accurate and precise yet presented for the cluster and is incompatible with the Hipparcos distance determination. Our results cement existing astrophysical models for Pleiades-age stars. Copyright © 2014, American Association for the Advancement of Science.

  15. Association between cultural distance and migrant self-rated health

    OpenAIRE

    Detollenaere, Jens; Baert, Stijn; Willems, Sara

    2018-01-01

    Abstract: We study whether migrant health in Europe is associated with the cultural distance between their host country and country of origin. To this end, we run multilevel regression models on data merging self-rated health and social background of ae3800 migrants from the European Social Survey with an index of cultural distance based on country differences in values, norms and attitudes measured in the World Values Survey. We find that higher levels of cultural distance are associated wit...

  16. Assessing distances and consistency of kinematics in Gaia/TGAS

    Science.gov (United States)

    Schönrich, Ralph; Aumer, Michael

    2017-12-01

    We apply the statistical methods by Schönrich, Binney & Asplund to assess the quality of distances and kinematics in the Radial Velocity Experiment (RAVE)-Tycho-Gaia Astrometric Solution (TGAS) and Large Sky Area Multiobject Fiber Spectroscopic Telescope (LAMOST)-TGAS samples of Solar neighbourhood stars. These methods yield a nominal distance accuracy of 1-2 per cent. Other than common tests on parallax accuracy, they directly test distance estimations including the effects of distance priors. We show how to construct these priors including the survey selection functions (SSFs) directly from the data. We demonstrate that neglecting the SSFs causes severe distance biases. Due to the decline of the SSFs in distance, the simple 1/parallax estimate only mildly underestimates distances. We test the accuracy of measured line-of-sight velocities (vlos) by binning the samples in the nominal vlos uncertainties. We find: (i) the LAMOST vlos have a ∼-5 km s-1 offset; (ii) the average LAMOST measurement error for vlos is ∼7 km s-1, significantly smaller than, and nearly uncorrelated with the nominal LAMOST estimates. The RAVE sample shows either a moderate distance underestimate, or an unaccounted source of vlos dispersion (e∥) from measurement errors and binary stars. For a subsample of suspected binary stars in RAVE, our methods indicate significant distance underestimates. Separating a sample in metallicity or kinematics to select thick-disc/halo stars, discriminates between distance bias and e∥. For LAMOST, this separation yields consistency with pure vlos measurement errors. We find an anomaly near longitude l ∼ (300 ± 60)° and distance s ∼ (0.32 ± 0.03) kpc on both sides of the galactic plane, which could be explained by either a localized distance error or a breathing mode.

  17. Average geodesic distance of skeleton networks of Sierpinski tetrahedron

    Science.gov (United States)

    Yang, Jinjin; Wang, Songjing; Xi, Lifeng; Ye, Yongchao

    2018-04-01

    The average distance is concerned in the research of complex networks and is related to Wiener sum which is a topological invariant in chemical graph theory. In this paper, we study the skeleton networks of the Sierpinski tetrahedron, an important self-similar fractal, and obtain their asymptotic formula for average distances. To provide the formula, we develop some technique named finite patterns of integral of geodesic distance on self-similar measure for the Sierpinski tetrahedron.

  18. INTERPRETING THE DISTANCE CORRELATION RESULTS FOR THE COMBO-17 SURVEY

    International Nuclear Information System (INIS)

    Richards, Mercedes T.; Richards, Donald St. P.; Martínez-Gómez, Elizabeth

    2014-01-01

    The accurate classification of galaxies in large-sample astrophysical databases of galaxy clusters depends sensitively on the ability to distinguish between morphological types, especially at higher redshifts. This capability can be enhanced through a new statistical measure of association and correlation, called the distance correlation coefficient, which has more statistical power to detect associations than does the classical Pearson measure of linear relationships between two variables. The distance correlation measure offers a more precise alternative to the classical measure since it is capable of detecting nonlinear relationships that may appear in astrophysical applications. We showed recently that the comparison between the distance and Pearson correlation coefficients can be used effectively to isolate potential outliers in various galaxy data sets, and this comparison has the ability to confirm the level of accuracy associated with the data. In this work, we elucidate the advantages of distance correlation when applied to large databases. We illustrate how the distance correlation measure can be used effectively as a tool to confirm nonlinear relationships between various variables in the COMBO-17 database, including the lengths of the major and minor axes, and the alternative redshift distribution. For these outlier pairs, the distance correlation coefficient is routinely higher than the Pearson coefficient since it is easier to detect nonlinear relationships with distance correlation. The V-shaped scatter plots of Pearson versus distance correlation coefficients also reveal the patterns with increasing redshift and the contributions of different galaxy types within each redshift range

  19. Reducing the distance in distance-caregiving by technology innovation

    Directory of Open Access Journals (Sweden)

    Lazelle E Benefield

    2007-07-01

    Full Text Available Lazelle E Benefield1, Cornelia Beck21College of Nursing, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA; 2Pat & Willard Walker Family Memory Research Center, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USAAbstract: Family caregivers are responsible for the home care of over 34 million older adults in the United States. For many, the elder family member lives more than an hour’s distance away. Distance caregiving is a growing alternative to more familiar models where: 1 the elder and the family caregiver(s may reside in the same household; or 2 the family caregiver may live nearby but not in the same household as the elder. The distance caregiving model involves elders and their family caregivers who live at some distance, defined as more than a 60-minute commute, from one another. Evidence suggests that distance caregiving is a distinct phenomenon, differs substantially from on-site family caregiving, and requires additional assistance to support the physical, social, and contextual dimensions of the caregiving process. Technology-based assists could virtually connect the caregiver and elder and provide strong support that addresses the elder’s physical, social, cognitive, and/or sensory impairments. Therefore, in today’s era of high technology, it is surprising that so few affordable innovations are being marketed for distance caregiving. This article addresses distance caregiving, proposes the use of technology innovation to support caregiving, and suggests a research agenda to better inform policy decisions related to the unique needs of this situation.Keywords: caregiving, family, distance, technology, elders

  20. Equivalence of massive propagator distance and mathematical distance on graphs

    International Nuclear Information System (INIS)

    Filk, T.

    1992-01-01

    It is shown in this paper that the assignment of distance according to the massive propagator method and according to the mathematical definition (length of minimal path) on arbitrary graphs with a bound on the degree leads to equivalent large scale properties of the graph. Especially, the internal scaling dimension is the same for both definitions. This result holds for any fixed, non-vanishing mass, so that a really inequivalent definition of distance requires the limit m → 0

  1. Time-Distance Helioseismology: Noise Estimation

    Science.gov (United States)

    Gizon, L.; Birch, A. C.

    2004-10-01

    As in global helioseismology, the dominant source of noise in time-distance helioseismology measurements is realization noise due to the stochastic nature of the excitation mechanism of solar oscillations. Characterizing noise is important for the interpretation and inversion of time-distance measurements. In this paper we introduce a robust definition of travel time that can be applied to very noisy data. We then derive a simple model for the full covariance matrix of the travel-time measurements. This model depends only on the expectation value of the filtered power spectrum and assumes that solar oscillations are stationary and homogeneous on the solar surface. The validity of the model is confirmed through comparison with SOHO MDI measurements in a quiet-Sun region. We show that the correlation length of the noise in the travel times is about half the dominant wavelength of the filtered power spectrum. We also show that the signal-to-noise ratio in quiet-Sun travel-time maps increases roughly as the square root of the observation time and is at maximum for a distance near half the length scale of supergranulation.

  2. Prediction of protein conformational freedom from distance constraints

    NARCIS (Netherlands)

    de Groot, B.L.; van Aalten, D.M.F.; Scheek, R.M.; Amadei, A; Vriend, G.; Berendsen, H.J.C.

    1997-01-01

    A method is presented that generates random protein structures that fulfil a set of upper and lower interatomic distance limits, These limits depend on distances measured in experimental structures and the strength of the interatomic interaction, Structural differences between generated structures

  3. Distances, metallicities and origins of high-velocity clouds

    NARCIS (Netherlands)

    van Woerden, H; Wakker, BP; Peletier, RF; Schwarz, UJ; KraanKorteweg, RC; Henning, PA; Andernach, H

    2000-01-01

    A review is given of distances of high-velocity clouds (HVCs) derived from absorption-line measurements, and of the metallicities of HVCs. Chain A definitely lies in the Galactic halo, between 2.5 and 7 kpc above the plane. The distance limits available for other HVCs allow a variety of locations:

  4. Academy Distance Learning Tools (IRIS) -

    Data.gov (United States)

    Department of Transportation — IRIS is a suite of front-end web applications utilizing a centralized back-end Oracle database. The system fully supports the FAA Academy's Distance Learning Program...

  5. Distance labeling schemes for trees

    DEFF Research Database (Denmark)

    Alstrup, Stephen; Gørtz, Inge Li; Bistrup Halvorsen, Esben

    2016-01-01

    We consider distance labeling schemes for trees: given a tree with n nodes, label the nodes with binary strings such that, given the labels of any two nodes, one can determine, by looking only at the labels, the distance in the tree between the two nodes. A lower bound by Gavoille et al. [Gavoille...... variants such as, for example, small distances in trees [Alstrup et al., SODA, 2003]. We improve the known upper and lower bounds of exact distance labeling by showing that 1/4 log2(n) bits are needed and that 1/2 log2(n) bits are sufficient. We also give (1 + ε)-stretch labeling schemes using Theta...

  6. A Short-Range Distance Sensor with Exceptional Linearity

    Science.gov (United States)

    Simmons, Steven; Youngquist, Robert

    2013-01-01

    A sensor has been demonstrated that can measure distance over a total range of about 300 microns to an accuracy of about 0.1 nm (resolution of about 0.01 nm). This represents an exceptionally large dynamic range of operation - over 1,000,000. The sensor is optical in nature, and requires the attachment of a mirror to the object whose distance is being measured. This work resulted from actively developing a white light interferometric system to be used to measure the depths of defects in the Space Shuttle Orbiter windows. The concept was then applied to measuring distance. The concept later expanded to include spectrometer calibration. In summary, broadband (i.e., white) light is launched into a Michelson interferometer, one mirror of which is fixed and one of which is attached to the object whose distance is to be measured. The light emerging from the interferometer has traveled one of two distances: either the distance to the fixed mirror and back, or the distance to the moving mirror and back. These two light beams mix and produce an interference pattern where some wavelengths interfere constructively and some destructively. Sending this light into a spectrometer allows this interference pattern to be analyzed, yielding the net distance difference between the two paths. The unique feature of this distance sensor is its ability to measure accurately distance over a dynamic range of more than one million, the ratio of its range (about 300 microns) to its accuracy (about 0.1 nanometer). Such a large linear operating range is rare and arises here because both amplitude and phase-matching algorithms contribute to the performance. The sensor is limited by the need to attach a mirror of some kind to the object being tracked, and by the fairly small total range, but the exceptional dynamic range should make it of interest.

  7. Distance Education in Technological Age

    OpenAIRE

    R .C. SHARMA

    2005-01-01

    Distance Education in Technological AgeRomesh Verma (Editor), New Delhi: Anmol Publications, 2005, ISBN 81-261-2210-2, pp. 419 Reviewed by R C SHARMARegional DirectorIndira Gandhi National Open University-INDIA The advancements in information and communication technologies have brought significant changes in the way the open and distance learning are provided to the learners. The impact of such changes is quite visible in both developed and developing countries. Switching over to online mode...

  8. TOPSIS with statistical distances: A new approach to MADM

    Directory of Open Access Journals (Sweden)

    Vijaya Babu Vommi

    2017-01-01

    Full Text Available Multiple attribute decision making (MADM methods are very useful in choosing the best alternative among the available finite but conflicting alternatives. TOPSIS is one of the MADM methods, which is simple in its methodology and logic. In TOPSIS, Euclidean distances of each alternative from the positive and negative ideal solutions are utilized to find the best alternative. In literature, apart from Euclidean distances, the city block distances have also been tried to find the separations measures. In general, the attribute data are distributed with unequal ranges and also possess moderate to high correlations. Hence, in the present paper, use of statistical distances is proposed in place of Euclidean distances. Procedures to find the best alternatives are developed using statistical and weighted statistical distances respectively. The proposed methods are illustrated with some industrial problems taken from literature. Results show that the proposed methods can be used as new alternatives in MADM for choosing the best solutions.

  9. Species turnover and geographic distance in an urban river network

    DEFF Research Database (Denmark)

    Rouquette, James R.; Dallimer, Martin; Armsworth, Paul R.

    2013-01-01

    AimUnderstanding the relationships between species turnover, environmental features and the geographic distance between sites can provide important insights into the processes driving species diversity. This is particularly relevant where the effective distance between sites may be a function...... patterns of species turnover and to determine whether these patterns differ between different taxonomic groups. LocationSheffield area, UK. MethodsAquatic (macroinvertebrates, diatoms) and terrestrial (birds, plants, butterflies) organisms were surveyed at 41 sites across an urban river network. We...... of the geographic distance measures, although network distance remained significant for birds and some plant groups after removing the effect of environmental distance. Water-dispersed and neophyte plant groups were significantly related to network and flow distance. Main conclusionsThe results suggest that aquatic...

  10. The interuncal distance in elderly patients with dementia; MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Takasaki, Masaru [Tokyo Medical Coll. (Japan); Sugiyama, Takeshi; Abe, Shinei; Kobayashi, Yasutaka; Maehata, Yukihiko; Katsunuma, Hidetaka

    1993-09-01

    The interuncal distance between the unci of the temporal lobes was measured from axial MR images of the brain in elderly patients with dementia including dementia of the Alzheimer type (DAT), vascular dementia (VD), and others. The measured value of the interuncal distance completely separated patients with DAT from normal controls, and there was significant diference in the interuncal distance between patients with DAT and VD. This measurement is a practical method of assessing hippocampal atrophy and appears to be a useful adjunct in the clinical diagnosis of DAT. (author).

  11. The interuncal distance in elderly patients with dementia

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Takasaki, Masaru; Sugiyama, Takeshi; Abe, Shinei; Kobayashi, Yasutaka; Maehata, Yukihiko; Katsunuma, Hidetaka.

    1993-01-01

    The interuncal distance between the unci of the temporal lobes was measured from axial MR images of the brain in elderly patients with dementia including dementia of the Alzheimer type (DAT), vascular dementia (VD), and others. The measured value of the interuncal distance completely separated patients with DAT from normal controls, and there was significant diference in the interuncal distance between patients with DAT and VD. This measurement is a practical method of assessing hippocampal atrophy and appears to be a useful adjunct in the clinical diagnosis of DAT. (author)

  12. Nanomechanical characterization by double-pass force-distance mapping

    Energy Technology Data Exchange (ETDEWEB)

    Dagdas, Yavuz S; Tekinay, Ayse B; Guler, Mustafa O; Dana, Aykutlu [UNAM Institute of Materials Science and Nanotechnology, Bilkent University, 06800 Ankara (Turkey); Necip Aslan, M, E-mail: aykutlu@unam.bilkent.edu.tr [Department of Physics, Istanbul Technical University, Istanbul (Turkey)

    2011-07-22

    We demonstrate high speed force-distance mapping using a double-pass scheme. The topography is measured in tapping mode in the first pass and this information is used in the second pass to move the tip over the sample. In the second pass, the cantilever dither signal is turned off and the sample is vibrated. Rapid (few kHz frequency) force-distance curves can be recorded with small peak interaction force, and can be processed into an image. Such a double-pass measurement eliminates the need for feedback during force-distance measurements. The method is demonstrated on self-assembled peptidic nanofibers.

  13. Nanomechanical characterization by double-pass force-distance mapping

    International Nuclear Information System (INIS)

    Dagdas, Yavuz S; Tekinay, Ayse B; Guler, Mustafa O; Dana, Aykutlu; Necip Aslan, M

    2011-01-01

    We demonstrate high speed force-distance mapping using a double-pass scheme. The topography is measured in tapping mode in the first pass and this information is used in the second pass to move the tip over the sample. In the second pass, the cantilever dither signal is turned off and the sample is vibrated. Rapid (few kHz frequency) force-distance curves can be recorded with small peak interaction force, and can be processed into an image. Such a double-pass measurement eliminates the need for feedback during force-distance measurements. The method is demonstrated on self-assembled peptidic nanofibers.

  14. Semiconductor Laser Tracking Frequency Distance Gauge

    Science.gov (United States)

    Phillips, James D.; Reasenberg, Robert D.

    2009-01-01

    Advanced astronomical missions with greatly enhanced resolution and physics missions of unprecedented accuracy will require a spaceworthy laser distance gauge of substantially improved performance. The Tracking Frequency Gauge (TFG) uses a single beam, locking a laser to the measurement interferometer. We have demonstrated this technique with pm (10(exp -12) m) performance. We report on the version we are now developing based on space-qualifiable, fiber-coupled distributed-feedback semiconductor lasers.

  15. Bony orbital distances among the Filipino population.

    Science.gov (United States)

    Barone, Constance M; Jimenez, David F; Laskey, Antoinette; Alcantara, Briccio G; Braddock, Stephen R

    2002-03-01

    Six hundred and seventy seven radiographs were selected from the logs of films taken in a major hospital in Metro Manila, Philippines over the course of the previous year. Two hundred and eighty-eight female and 389 male, healthy Filipinos between the ages of birth and twenty years were selected based on the availability of a modified Waters' projection and lateral skull film taken at the same time. Measurements for the lateral orbital wall were made at the site of the suture on the medial surface of the zygomatic bone. The medial orbital wall measurement was the distance between the dacrya using a correction factor formula of CF = D-d/D where D is the target film distance and d is the object film distance (1). The actual bony measurements were calculated. The data was gathered and plotted according to sex and in age in years. Graphs were generated using SAS over a graph software. Lines were smooth using cubic spline technique developed by Reinsch with the smoothest value of 75 (2). The mean plus two, four, and six standard deviations were included in each of the curves.

  16. Giant sparks at cosmological distances?

    International Nuclear Information System (INIS)

    Kulkarni, S. R.; Ofek, E. O.; Neill, J. D.; Zheng, Z.; Juric, M.

    2014-01-01

    Millisecond-duration bright radio pulses at 1.4 GHz with high dispersion measures (DMs) were reported by Lorimer et al., Keane et al., and Thornton et al. Their all-sky rate is ≈10 4 day –1 above ∼1 Jy. Related events are 'Perytons'–similar pulsed, dispersed sources, but most certainly local. Suggested models of fast radio bursts (FRBs) can originate in Earth's atmosphere, in stellar coronae, in other galaxies, and even at cosmological distances. Using physically motivated assumptions combined with observed properties, we explore these models. In our analysis, we focus on the Lorimer event: a 30 Jy, 5 ms duration burst with DM = 375 cm –3 pc, exhibiting a steep frequency-dependent pulse width (the Sparker). To be complete, we drop the assumption that high DMs are produced by plasma propagation and assume that the source produces pulses with frequency-dependent arrival time ('chirped signals'). Within this framework, we explore a scenario in which Perytons, the Sparker, and the FRBs are all atmospheric phenomena occurring at different heights. This model is ad hoc in that we cannot explain why Perytons at higher altitudes show greater DMs or exhibit narrower pulses. Nonetheless, we argue that the Sparker may be a Peryton. We end with two remarks. First, the detection of a single FRB by an interferometer with a kilometer (or longer) baseline will prove that FRBs are of extraterrestrial origin. Second, we urge astronomers to pursue observations and understanding of Perytons since they form (at least) a formidable foreground for the FRBs.

  17. Giant sparks at cosmological distances?

    Energy Technology Data Exchange (ETDEWEB)

    Kulkarni, S. R. [Caltech Optical Observatories 249-17, California Institute of Technology, Pasadena, CA 91125 (United States); Ofek, E. O. [Department of Particle Physics and Astrophysics, Weizmann Institute of Science, Rehovot 76100 (Israel); Neill, J. D. [Space Radiation Laboratory 290-17, California Institute of Technology, Pasadena, CA 91125 (United States); Zheng, Z. [Department of Physics and Astronomy, University of Utah, 115 South 1400 East 201, Salt Lake City, UT 84112 (United States); Juric, M. [Department of Astronomy, University of Washington, Box 351580, Seattle, WA 98195 (United States)

    2014-12-10

    Millisecond-duration bright radio pulses at 1.4 GHz with high dispersion measures (DMs) were reported by Lorimer et al., Keane et al., and Thornton et al. Their all-sky rate is ≈10{sup 4} day{sup –1} above ∼1 Jy. Related events are 'Perytons'–similar pulsed, dispersed sources, but most certainly local. Suggested models of fast radio bursts (FRBs) can originate in Earth's atmosphere, in stellar coronae, in other galaxies, and even at cosmological distances. Using physically motivated assumptions combined with observed properties, we explore these models. In our analysis, we focus on the Lorimer event: a 30 Jy, 5 ms duration burst with DM = 375 cm{sup –3} pc, exhibiting a steep frequency-dependent pulse width (the Sparker). To be complete, we drop the assumption that high DMs are produced by plasma propagation and assume that the source produces pulses with frequency-dependent arrival time ('chirped signals'). Within this framework, we explore a scenario in which Perytons, the Sparker, and the FRBs are all atmospheric phenomena occurring at different heights. This model is ad hoc in that we cannot explain why Perytons at higher altitudes show greater DMs or exhibit narrower pulses. Nonetheless, we argue that the Sparker may be a Peryton. We end with two remarks. First, the detection of a single FRB by an interferometer with a kilometer (or longer) baseline will prove that FRBs are of extraterrestrial origin. Second, we urge astronomers to pursue observations and understanding of Perytons since they form (at least) a formidable foreground for the FRBs.

  18. Does obesity preclude lumbar puncture with a standard spinal needle? The use of computed tomography to measure the skin to lumbar subarachnoid space distance in the general hospital population.

    LENUS (Irish Health Repository)

    Halpenny, Darragh

    2013-06-05

    OBJECTIVES: Failed lumbar puncture (LP) is a common indication for referral for radiologically guided LP. This study aims to evaluate what percentage of the hospital population would fail an LP using a standard 9-cm needle because of obesity and a skin to subarachnoid space distance greater than 9 cm. METHODS: Images of 402 consecutive patients undergoing computed tomography of the abdomen and pelvis were reviewed. Skin to subarachnoid space distance was calculated using sagittal images. A survey was conducted among junior hospital doctors to assess their experience of performing lumbar puncture in obese patients. RESULTS: Four hundred patients were included. Fifty-five patients (13.8 %) had a skin to subarachnoid space distance greater than 9 cm. Intra-abdominal fat, subcutaneous fat and abdominal girth correlated with distance between the skin and subarachnoid space. Among junior doctors, 68.3 % (n = 41) reported LP failure on an obese patient; 78.4 % (n = 47) were unaware of the existence of a longer needle and 13.3 % (n = 8) had experience using a longer needle. CONCLUSIONS: A significant proportion of the hospital population will fail LP with a standard length spinal needle. Selecting a longer needle may be sufficient to successfully complete LP in obese patients. KEY POINTS : • Lumbar puncture failure commonly leads to referral for an image-guided procedure • Standard lumbar puncture may fail in 13.8 % of patients due to obesity • 78.4 % of trainee doctors are unaware of the existence of longer spinal-needles • Using longer spinal needles may allow successful LP in obese patients.

  19. Computing Distances between Probabilistic Automata

    Directory of Open Access Journals (Sweden)

    Mathieu Tracol

    2011-07-01

    Full Text Available We present relaxed notions of simulation and bisimulation on Probabilistic Automata (PA, that allow some error epsilon. When epsilon is zero we retrieve the usual notions of bisimulation and simulation on PAs. We give logical characterisations of these notions by choosing suitable logics which differ from the elementary ones, L with negation and L without negation, by the modal operator. Using flow networks, we show how to compute the relations in PTIME. This allows the definition of an efficiently computable non-discounted distance between the states of a PA. A natural modification of this distance is introduced, to obtain a discounted distance, which weakens the influence of long term transitions. We compare our notions of distance to others previously defined and illustrate our approach on various examples. We also show that our distance is not expansive with respect to process algebra operators. Although L without negation is a suitable logic to characterise epsilon-(bisimulation on deterministic PAs, it is not for general PAs; interestingly, we prove that it does characterise weaker notions, called a priori epsilon-(bisimulation, which we prove to be NP-difficult to decide.

  20. Distance sampling methods and applications

    CERN Document Server

    Buckland, S T; Marques, T A; Oedekoven, C S

    2015-01-01

    In this book, the authors cover the basic methods and advances within distance sampling that are most valuable to practitioners and in ecology more broadly. This is the fourth book dedicated to distance sampling. In the decade since the last book published, there have been a number of new developments. The intervening years have also shown which advances are of most use. This self-contained book covers topics from the previous publications, while also including recent developments in method, software and application. Distance sampling refers to a suite of methods, including line and point transect sampling, in which animal density or abundance is estimated from a sample of distances to detected individuals. The book illustrates these methods through case studies; data sets and computer code are supplied to readers through the book’s accompanying website.  Some of the case studies use the software Distance, while others use R code. The book is in three parts.  The first part addresses basic methods, the ...

  1. Euclidean distance geometry an introduction

    CERN Document Server

    Liberti, Leo

    2017-01-01

    This textbook, the first of its kind, presents the fundamentals of distance geometry:  theory, useful methodologies for obtaining solutions, and real world applications. Concise proofs are given and step-by-step algorithms for solving fundamental problems efficiently and precisely are presented in Mathematica®, enabling the reader to experiment with concepts and methods as they are introduced. Descriptive graphics, examples, and problems, accompany the real gems of the text, namely the applications in visualization of graphs, localization of sensor networks, protein conformation from distance data, clock synchronization protocols, robotics, and control of unmanned underwater vehicles, to name several.  Aimed at intermediate undergraduates, beginning graduate students, researchers, and practitioners, the reader with a basic knowledge of linear algebra will gain an understanding of the basic theories of distance geometry and why they work in real life.

  2. Geodesic distance in planar graphs

    International Nuclear Information System (INIS)

    Bouttier, J.; Di Francesco, P.; Guitter, E.

    2003-01-01

    We derive the exact generating function for planar maps (genus zero fatgraphs) with vertices of arbitrary even valence and with two marked points at a fixed geodesic distance. This is done in a purely combinatorial way based on a bijection with decorated trees, leading to a recursion relation on the geodesic distance. The latter is solved exactly in terms of discrete soliton-like expressions, suggesting an underlying integrable structure. We extract from this solution the fractal dimensions at the various (multi)-critical points, as well as the precise scaling forms of the continuum two-point functions and the probability distributions for the geodesic distance in (multi)-critical random surfaces. The two-point functions are shown to obey differential equations involving the residues of the KdV hierarchy

  3. Distance to VY Canis Majoris with VERA

    Science.gov (United States)

    Choi, Yoon Kyung; Hirota, Tomoya; Honma, Mareki; Kobayashi, Hideyuki; Bushimata, Takeshi; Imai, Hiroshi; Iwadate, Kenzaburo; Jike, Takaaki; Kameno, Seiji; Kameya, Osamu; Kamohara, Ryuichi; Kan-Ya, Yukitoshi; Kawaguchi, Noriyuki; Kijima, Masachika; Kim, Mi Kyoung; Kuji, Seisuke; Kurayama, Tomoharu; Manabe, Seiji; Maruyama, Kenta; Matsui, Makoto; Matsumoto, Naoko; Miyaji, Takeshi; Nagayama, Takumi; Nakagawa, Akiharu; Nakamura, Kayoko; Oh, Chung Sik; Omodaka, Toshihiro; Oyama, Tomoaki; Sakai, Satoshi; Sasao, Tetsuo; Sato, Katsuhisa; Sato, Mayumi; Shibata, Katsunori M.; Tamura, Yoshiaki; Tsushima, Miyuki; Yamashita, Kazuyoshi

    2008-10-01

    We report on astrometric observations of H2O masers around the red supergiant VY Canis Majoris carried out with VLBI Exploration of Radio Astrometry (VERA). Based on astrometric monitoring for 13 months, we successfully measured a trigonometric parallax of 0.88±0.08 mas, corresponding to a distance of 1.14+0.11-0.09kpc. This is the most accurate determined distance to VY CMa and the first one based on an annual parallax measurement. The luminosity of VY CMa has been overestimated due to a previously accepted distance. With our result, we re-estimated the luminosity of VY CMa to be (3±0.5) × 105Lodot using the bolometric flux integrated over optical and IR wavelengths. This improved luminosity value makes the location of VY CMa on the Hertzsprung-Russell (HR) diagram much closer to the theoretically allowable zone (i.e. the left side of the Hayashi track) than previous ones, though the uncertainty in the effective temperature of the stellar surface still does not permit us to make a final conclusion.

  4. Distance stereotest using a 3-dimensional monitor for adult subjects.

    Science.gov (United States)

    Kim, Jongshin; Yang, Hee Kyung; Kim, Youngmin; Lee, Byoungho; Hwang, Jeong-Min

    2011-06-01

    To evaluate the validity and test-retest reliability of a contour-based 3-dimensional (3-D) monitor distance stereotest (distance 3-D stereotest) and to measure the maximum horizontal disparity that can be fused with disparity vergence for determining the largest measurable disparity of true stereopsis. Observational case series. Sixty-four normal adult subjects (age range, 23 to 39 years) were recruited. Contour-based circles (crossed disparity, 5000 to 20 seconds of arc; Microsoft Visual Studio C(++) 6.0; Microsoft, Inc, Seattle, Washington, USA) were generated on a 3-D monitor (46-inch stereoscopic display) using polarization glasses and were presented to subjects with normal binocularity at 3 m. While the position of the stimulus changed among 4 possible locations, the subjects were instructed to press the corresponding position of the stimulus on a keypad. The results with the new distance 3-D stereotest were compared with those from the distance Randot stereotest. The results of the distance 3-D stereotest and the distance Randot stereotests were identical in 64% and within 1 disparity level in 97% of normal adults. Scores obtained with the 2 tests showed a statistically significant correlation (r = 0.324, P = .009). The half-width of the 95% limit of agreement was 0.47 log seconds of arc (1.55 octaves) using the distance 3-D stereotest--similar to or better than that obtained with conventional distance stereotests. The maximum binocular disparity that can be fused with vergence was 1828 ± 794 seconds of arc (range, 4000 to 500). The distance 3-D stereotest showed good concordance with the distance Randot stereotest and relatively good test-retest reliability, supporting the validity of the distance 3-D stereotest. The normative data set obtained from the present study can serve as a useful reference for quantitative assessment of a wide range of binocular sensory abnormalities. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Connecting long distance: semantic distance in analogical reasoning modulates frontopolar cortex activity.

    Science.gov (United States)

    Green, Adam E; Kraemer, David J M; Fugelsang, Jonathan A; Gray, Jeremy R; Dunbar, Kevin N

    2010-01-01

    Solving problems often requires seeing new connections between concepts or events that seemed unrelated at first. Innovative solutions of this kind depend on analogical reasoning, a relational reasoning process that involves mapping similarities between concepts. Brain-based evidence has implicated the frontal pole of the brain as important for analogical mapping. Separately, cognitive research has identified semantic distance as a key characteristic of the kind of analogical mapping that can support innovation (i.e., identifying similarities across greater semantic distance reveals connections that support more innovative solutions and models). However, the neural substrates of semantically distant analogical mapping are not well understood. Here, we used functional magnetic resonance imaging (fMRI) to measure brain activity during an analogical reasoning task, in which we parametrically varied the semantic distance between the items in the analogies. Semantic distance was derived quantitatively from latent semantic analysis. Across 23 participants, activity in an a priori region of interest (ROI) in left frontopolar cortex covaried parametrically with increasing semantic distance, even after removing effects of task difficulty. This ROI was centered on a functional peak that we previously associated with analogical mapping. To our knowledge, these data represent a first empirical characterization of how the brain mediates semantically distant analogical mapping.

  6. The Concept of Distance in International Management Research

    DEFF Research Database (Denmark)

    Ambos, Björn; Håkanson, Lars

    2014-01-01

    The effect of distance on firms' performance when entering, operating in and across foreign markets is a central issue in international management. However, our understanding of the impact of distance has long been constrained by flawed conceptualizations and unreliable measures. The papers...... in this issue break new ground both by advancing our theoretical understanding and by introducing new and potentially more useful measures. In this introduction, we provide a brief overview of the evolution of the distance concept before introducing the individual papers. We end by offering observations...... for future research based on the issues they raise....

  7. Auditory/visual distance estimation: accuracy and variability

    Directory of Open Access Journals (Sweden)

    Paul Wallace Anderson

    2014-10-01

    Full Text Available Past research has shown that auditory distance estimation improves when listeners are given the opportunity to see all possible sound sources when compared to no visual input. It has also been established that distance estimation is more accurate in vision than in audition. The present study investigates the degree to which auditory distance estimation is improved when matched with a congruent visual stimulus. Virtual sound sources based on binaural room impulse response (BRIR measurements made from distances ranging from approximately 0.3 to 9.8 m in a concert hall were used as auditory stimuli. Visual stimuli were photographs taken from the listener’s perspective at each distance in the impulse response measurement setup presented on a large HDTV monitor. Listeners were asked to estimate egocentric distance to the sound source in each of three conditions: auditory only (A, visual only (V, and congruent auditory/visual stimuli (A+V. Each condition was presented within its own block. Sixty-two listeners were tested in order to quantify the response variability inherent in auditory distance perception. Distance estimates from both the V and A+V conditions were found to be considerably more accurate and less variable than estimates from the A condition.

  8. Fast Exact Euclidean Distance (FEED) Transformation

    NARCIS (Netherlands)

    Schouten, Theo; Kittler, J.; van den Broek, Egon; Petrou, M.; Nixon, M.

    2004-01-01

    Fast Exact Euclidean Distance (FEED) transformation is introduced, starting from the inverse of the distance transformation. The prohibitive computational cost of a naive implementation of traditional Euclidean Distance Transformation, is tackled by three operations: restriction of both the number

  9. Steiner Distance in Graphs--A Survey

    OpenAIRE

    Mao, Yaping

    2017-01-01

    For a connected graph $G$ of order at least $2$ and $S\\subseteq V(G)$, the \\emph{Steiner distance} $d_G(S)$ among the vertices of $S$ is the minimum size among all connected subgraphs whose vertex sets contain $S$. In this paper, we summarize the known results on the Steiner distance parameters, including Steiner distance, Steiner diameter, Steiner center, Steiner median, Steiner interval, Steiner distance hereditary graph, Steiner distance stable graph, average Steiner distance, and Steiner ...

  10. Partial distance correlation with methods for dissimilarities

    OpenAIRE

    Székely, Gábor J.; Rizzo, Maria L.

    2014-01-01

    Distance covariance and distance correlation are scalar coefficients that characterize independence of random vectors in arbitrary dimension. Properties, extensions, and applications of distance correlation have been discussed in the recent literature, but the problem of defining the partial distance correlation has remained an open question of considerable interest. The problem of partial distance correlation is more complex than partial correlation partly because the squared distance covari...

  11. Inland Waters - Navigation Distance Mark - Red River of the North (Non-Navigable)

    Data.gov (United States)

    Army Corps of Engineers, Department of the Army, Department of Defense — A distance mark indicates the distance measured from an origin and consists of a distinct location without special installation, used to serve as a reference along...

  12. Gesture Interaction at a Distance

    NARCIS (Netherlands)

    Fikkert, F.W.

    2010-01-01

    The aim of this work is to explore, from a perspective of human behavior, which gestures are suited to control large display surfaces from a short distance away; why that is so; and, equally important, how such an interface can be made a reality. A well-known example of the type of interface that is

  13. Communication Barriers in Distance Education

    Science.gov (United States)

    Isman, Aytekin; Dabaj, Fahme; Altinay, Fahriye; Altinay, Zehra

    2003-01-01

    Communication is a key concept as being the major tool for people in order to satisfy their needs. It is an activity which refers as process and effective communication requires qualified communication with the elimination of communication barriers. As it is known, distance education is a new trend by following contemporary facilities and tools…

  14. Distance Education Technologies in Asia

    International Development Research Centre (IDRC) Digital Library (Canada)

    17 schools ... Mobile Technology in Non-formal Distance Education 192 ..... in the design and application of e-learning strategies, the need to standardise and ...... library providing access to over 20,000 journals and thesis databases, and 6,000 ...

  15. Video surveillance using distance maps

    Science.gov (United States)

    Schouten, Theo E.; Kuppens, Harco C.; van den Broek, Egon L.

    2006-02-01

    Human vigilance is limited; hence, automatic motion and distance detection is one of the central issues in video surveillance. Hereby, many aspects are of importance, this paper specially addresses: efficiency, achieving real-time performance, accuracy, and robustness against various noise factors. To obtain fully controlled test environments, an artificial development center for robot navigation is introduced in which several parameters can be set (e.g., number of objects, trajectories and type and amount of noise). In the videos, for each following frame, movement of stationary objects is detected and pixels of moving objects are located from which moving objects are identified in a robust way. An Exact Euclidean Distance Map (E2DM) is utilized to determine accurately the distances between moving and stationary objects. Together with the determined distances between moving objects and the detected movement of stationary objects, this provides the input for detecting unwanted situations in the scene. Further, each intelligent object (e.g., a robot), is provided with its E2DM, allowing the object to plan its course of action. Timing results are specified for each program block of the processing chain for 20 different setups. So, the current paper presents extensive, experimentally controlled research on real-time, accurate, and robust motion detection for video surveillance, using E2DMs, which makes it a unique approach.

  16. Interaction in Distance Nursing Education

    Science.gov (United States)

    Boz Yuksekdag, Belgin

    2012-01-01

    The purpose of this study is to determine psychiatry nurses' attitudes toward the interactions in distance nursing education, and also scrunize their attitudes based on demographics and computer/Internet usage. The comparative relational scanning model is the method of this study. The research data were collected through "The Scale of Attitudes of…

  17. Student Monitoring in Distance Education.

    Science.gov (United States)

    Holt, Peter; And Others

    1987-01-01

    Reviews a computerized monitoring system for distance education students at Athabasca University designed to solve the problems of tracking student performance. A pilot project for tutors is described which includes an electronic conferencing system and electronic mail, and an evaluation currently in progress is briefly discussed. (LRW)

  18. Effect of Image Linearization on Normalized Compression Distance

    Science.gov (United States)

    Mortensen, Jonathan; Wu, Jia Jie; Furst, Jacob; Rogers, John; Raicu, Daniela

    Normalized Information Distance, based on Kolmogorov complexity, is an emerging metric for image similarity. It is approximated by the Normalized Compression Distance (NCD) which generates the relative distance between two strings by using standard compression algorithms to compare linear strings of information. This relative distance quantifies the degree of similarity between the two objects. NCD has been shown to measure similarity effectively on information which is already a string: genomic string comparisons have created accurate phylogeny trees and NCD has also been used to classify music. Currently, to find a similarity measure using NCD for images, the images must first be linearized into a string, and then compared. To understand how linearization of a 2D image affects the similarity measure, we perform four types of linearization on a subset of the Corel image database and compare each for a variety of image transformations. Our experiment shows that different linearization techniques produce statistically significant differences in NCD for identical spatial transformations.

  19. Estimating plant distance in maize using Unmanned Aerial Vehicle (UAV).

    Science.gov (United States)

    Zhang, Jinshui; Basso, Bruno; Price, Richard F; Putman, Gregory; Shuai, Guanyuan

    2018-01-01

    Distance between rows and plants are essential parameters that affect the final grain yield in row crops. This paper presents the results of research intended to develop a novel method to quantify the distance between maize plants at field scale using an Unmanned Aerial Vehicle (UAV). Using this method, we can recognize maize plants as objects and calculate the distance between plants. We initially developed our method by training an algorithm in an indoor facility with plastic corn plants. Then, the method was scaled up and tested in a farmer's field with maize plant spacing that exhibited natural variation. The results of this study demonstrate that it is possible to precisely quantify the distance between maize plants. We found that accuracy of the measurement of the distance between maize plants depended on the height above ground level at which UAV imagery was taken. This study provides an innovative approach to quantify plant-to-plant variability and, thereby final crop yield estimates.

  20. A Streaming Distance Transform Algorithm for Neighborhood-Sequence Distances

    Directory of Open Access Journals (Sweden)

    Nicolas Normand

    2014-09-01

    Full Text Available We describe an algorithm that computes a “translated” 2D Neighborhood-Sequence Distance Transform (DT using a look up table approach. It requires a single raster scan of the input image and produces one line of output for every line of input. The neighborhood sequence is specified either by providing one period of some integer periodic sequence or by providing the rate of appearance of neighborhoods. The full algorithm optionally derives the regular (centered DT from the “translated” DT, providing the result image on-the-fly, with a minimal delay, before the input image is fully processed. Its efficiency can benefit all applications that use neighborhood- sequence distances, particularly when pipelined processing architectures are involved, or when the size of objects in the source image is limited.