WorldWideScience

Sample records for international reference reagent

  1. International reference reagents: antihuman globulin. An ISBT/ICSH joint working party report. International Society of Blood Transfusion. International Committee for Standardization in Haematology.

    Science.gov (United States)

    Case, J; Ford, D S; Chung, A; Collins, R; Kochman, S; Mazda, T; Overbeeke, M; Perera, R; Sakuldamrongpanich, T; Scott, M; Voak, D; Zupańska, B

    1999-01-01

    An international working party has conducted a study designed to select a suitable reference reagent for antihuman globulin, to replace those first made available in 1987. The chosen preparation contains levels of anti-IgG and anti-C3 (anti-C3c and anti-C3d) potency that are considered suitable to serve for reference when evaluating either polyspecific antihuman globulin reagents or those containing their separate monospecific components. The reference material is available in 2-ml freeze-dried aliquots from seven assigned distribution centres.

  2. First WHO/IFCC International Reference Reagent for Lipoprotein(a) for Immunoassay--Lp(a) SRM 2B.

    Science.gov (United States)

    Dati, Francesco; Tate, Jillian R; Marcovina, Santica M; Steinmetz, Armin

    2004-01-01

    Lipoprotein(a) is an important predictor of cardiovascular disease risk. The lack of internationally accepted standardization has impeded the broad application of this lipoprotein in laboratory medicine. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), through its Working Group on Lipoprotein(a) and together with research institutions and several diagnostic companies, have succeeded in developing an international reference material that is intended for the transfer of a lipoprotein(a) concentration to manufacturers' master calibrators. IFCC SRM 2B has recently been accepted by the WHO Expert Committee on Biological Standardization as the 'First WHO/IFCC International Reference Reagent for Lipoprotein(a) for Immunoassay'. The assigned unitage of 0.1071 nanomoles of lipoprotein(a) per vial is traceable to the consensus reference method for lipoprotein(a) and will enable conformity by diagnostic companies to the European Union's Directive on In vitro Diagnostic Medical Devices for the metrological traceability of calibrator materials.

  3. The establishment of a WHO Reference Reagent for anti-malaria (Plasmodium falciparum) human serum.

    Science.gov (United States)

    Bryan, Donna; Silva, Nilupa; Rigsby, Peter; Dougall, Thomas; Corran, Patrick; Bowyer, Paul W; Ho, Mei Mei

    2017-08-05

    At a World Health Organization (WHO) sponsored meeting it was concluded that there is an urgent need for a reference preparation that contains antibodies against malaria antigens in order to support serology studies and vaccine development. It was proposed that this reference would take the form of a lyophilized serum or plasma pool from a malaria-endemic area. In response, an immunoassay standard, comprising defibrinated human plasma has been prepared and evaluated in a collaborative study. A pool of human plasma from a malaria endemic region was collected from 140 single plasma donations selected for reactivity to Plasmodium falciparum apical membrane antigen-1 (AMA-1) and merozoite surface proteins (MSP-1 19 , MSP-1 42 , MSP-2 and MSP-3). This pool was defibrinated, filled and freeze dried into a single batch of ampoules to yield a stable source of naturally occurring antibodies to P. falciparum. The preparation was evaluated by an enzyme-linked immunosorbent assay (ELISA) in a collaborative study with sixteen participants from twelve different countries. This anti-malaria human serum preparation (NIBSC Code: 10/198) was adopted by the WHO Expert Committee on Biological Standardization (ECBS) in October 2014, as the first WHO reference reagent for anti-malaria (Plasmodium falciparum) human serum with an assigned arbitrary unitage of 100 units (U) per ampoule. Analysis of the reference reagent in a collaborative study has demonstrated the benefit of this preparation for the reduction in inter- and intra-laboratory variability in ELISA. Whilst locally sourced pools are regularly use for harmonization both within and between a few laboratories, the presence of a WHO-endorsed reference reagent should enable optimal harmonization of malaria serological assays either by direct use of the reference reagent or calibration of local standards against this WHO reference. The intended uses of this reference reagent, a multivalent preparation, are (1) to allow cross

  4. Quantitative estimation of diphtheria and tetanus toxoids. 4. Toxoids as international reference materials defining Lf-units for diphtheria and tetanus toxoids.

    Science.gov (United States)

    Lyng, J

    1990-01-01

    The Lf-unit, which is used in the control of diphtheria and tetanus toxoid production and in some countries also to follow immunization of horses for production of antitoxins, has hitherto been defined by means of antitoxin preparations. A diphtheria toxoid and a tetanus toxoid preparation, both freeze-dried, were examined in an international collaborative study for their suitability to serve as reference reagents in the flocculation tests and for defining the Lf-units. It was shown that flocculation tests using the reference toxoids are very reproducible and reliable and the WHO Expert Committee on Biological Standardization established: the toxoid called DIFT as the International Reference Reagent of Diphtheria Toxoid for Flocculation Test with a defined content of 900 Lf-units of diphtheria toxoid per ampoule; and the toxoid called TEFT as the International Reference Reagent of Tetanus Toxoid for Flocculation Test with a defined content of 1000 Lf-units of diphtheria toxoid per ampoule.

  5. Evaluation of four commercial biuret reagent kits of serum total protein by the American Association for Clinical Chemistry reference measurement procedure.

    Science.gov (United States)

    He, Meilin; Zhang, Jie

    2011-06-01

    In China, the traceability of clinical chemistry methods is still immature. Therefore, it is necessary to establish a reference measurement procedure and evaluate commercial reagent kits using such established procedures. We reproduced the reference measurement procedure for serum total protein, as recommended by the American Association for Clinical Chemistry (AACC). We evaluated the performance by Clinical Laboratory Standard Institute (CLSI) guidelines EP15-A and EP6-A. Subsequently, four commercial reagent kits were evaluated by the reproduced reference procedure following CLSI guideline EP9-A2. The performance of the reproduced reference procedure was as follows: CVs ranged from 0.47% to 0.85% at medical decision levels (X(c)) of 45 g/L, 60 g/L and 80 g/L. Linearity was Y=1.0022X-0.2121 (r=0.9999), and recovery ranged from 100.2% to 102.4%. The External Quality Assessment Scheme for Reference Laboratories in Laboratory Medicine (RELA) was applied, and the result was within the limit of equivalence. The linear relationships of four commercial reagent kits, Merit Choice, KHB, Leadman, and Olympus, were, respectively: Y=0.9922X+0.5776 (r=0.9961); Y=0.9936X+0.4316 (r=0.9992); Y=0.9949X+0.9129 (r=0.9987) and Y=0.9923X+0.8876 (r=0.9989). KHB showed slight negative bias, and the mean±SD was -0.03±0.60 g/L. Merit Choice, Leadman, and Olympus all showed positive bias, and the mean±SDs were 0.02±0.63 g/L, 0.55±0.77 g/L and 0.34±0.71 g/L, respectively. The correlation and bias of four commercial reagent kits for serum total protein were found to be acceptable. Thus, these reagent kits can be used reliably in China.

  6. Sensor employing internal reference electrode

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention concerns a novel internal reference electrode as well as a novel sensing electrode for an improved internal reference oxygen sensor and the sensor employing same.......The present invention concerns a novel internal reference electrode as well as a novel sensing electrode for an improved internal reference oxygen sensor and the sensor employing same....

  7. An International Standard for specifying the minimum potency of anti-D blood-grouping reagents: evaluation of a candidate preparation in an international collaborative study

    NARCIS (Netherlands)

    Thorpe, S. J.; Fox, B.; Heath, A. B.; Scott, M.; de Haas, M.; Kochman, S.; Padilla, A.

    2006-01-01

    The aim of this study was to evaluate a lyophilized monoclonal immunoglobulin M (IgM) anti-D preparation for use as an International Standard to specify a recommended minimum acceptable potency of anti-D blood-grouping reagents. The candidate International Standard (99/836) for specifying the

  8. The Third International Reference Preparation of Egg Lecithin

    Science.gov (United States)

    Krag, P.; Bentzon, M. Weis

    1961-01-01

    The Third International Reference Preparation of Egg Lecithin was produced (in a quantity of 5000 ml) at the WHO Serological Reference Centre, Copenhagen, and assayed in 1958 against the Second International Reference Preparation by four laboratories in three countries. Complement-fixation and slide-flocculation tests were used. The new preparation was found acceptable, and its establishment was authorized by the WHO Expert Committee on Biological Standardization. The average log10 titres and results of analyses of variances are shown. The variances were of the usual order of magnitude, and the differences in titre between antigens containing the Second and the Third International Reference Preparations varied from -0.011 to 0.116; only one of the differences exceeded the 5% limit of significance. The use of the Third International Reference Preparation in tests for the acceptability of lecithin preparations is described. PMID:13753864

  9. 21 CFR 660.25 - Potency tests without reference preparations.

    Science.gov (United States)

    2010-04-01

    ... recommended for slide tests or microplate techniques. Blood Grouping Reagent recommended for slide test... Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood Grouping Reagents are not available shall be tested for potency by a method approved by the Director...

  10. International Geomagnetic Reference Field

    DEFF Research Database (Denmark)

    Finlay, Chris; Maus, S.; Beggan, C. D.

    2010-01-01

    The eleventh generation of the International Geomagnetic Reference Field (IGRF) was adopted in December 2009 by the International Association of Geomagnetism and Aeronomy Working Group V‐MOD. It updates the previous IGRF generation with a definitive main field model for epoch 2005.0, a main field...... model for epoch 2010.0, and a linear predictive secular variation model for 2010.0–2015.0. In this note the equations defining the IGRF model are provided along with the spherical harmonic coefficients for the eleventh generation. Maps of the magnetic declination, inclination and total intensity...

  11. Internal laboratory control in residue analysis of chlorinated hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    The thesis contains a chapter on gaschromatographic system in which gas current, temperatures, separation system, detector system, recorder, dosing system and integrator are described. The chapter on reagents deals with standards and solvents, absorbents and other reagents. The chapter on laboratory equipment deals with general recommendations for apparatus, purification and total numerical result of blank test. The chapter ''Methods'' contains general references, aptitude for a special problem, common investigations and control by standard reference materials. The chapter on the work up of samples treats extraction, purification, concentrating the solution, internal standard, multiple determination and control samples. The chapter on measurement presents calibration, internal standard, multiple determination, securing the result and control samples. The chapter on evaluation consists of qualitative and quantitave evaluation, decision criteria and communication of the result. The chapter of documentation described routine investigations, tests and controls of internal laboratory control, preliminary works, maintenance and service works.

  12. Hydrazine reagents as derivatizing agents in environmental analysis--a critical review.

    Science.gov (United States)

    Vogel, M; Büldt, A; Karst, U

    2000-04-01

    Hydrazine reagents are a well-known group of derivatizing agents for the determination of aldehydes and ketones in liquid and gaseous samples. Within this article, the most important hydrazine reagents are critically summarized, and their major applications in different fields, including environmental analysis, food chemistry and industrial analysis are introduced. As 2,4-dinitrophenylhydrazine (DNPH) is the basic reagent for several international standard procedures, its properties are discussed in detail. Particular focus is directed on the chemistry of the hydrazine reagents, and chemical interferences are considered. Recent methods for the determination of various oxidants using hydrazine reagents are presented as well. Due to limited space, this review does not cover the related field of carbohydrate analysis, although many chemical aspects are similar.

  13. Two Palladium-Catalyzed Domino Reactions from One Set of Substrates/Reagents: Efficient Synthesis of Substituted Indenes and cis-Stilbenoid Hydrocarbons from the Same Internal Alkynes and Hindered Grignard Reagents

    Science.gov (United States)

    Dong, Cheng-Guo; Yeung, Pik; Hu, Qiao-Sheng

    2008-01-01

    Two types of domino reactions from the same internal alkynes and hindered Grignard reagents based on carbopalladation, Pd-catalyzed cross-coupling reaction and C-H activation strategy are described. The realization of these domino reactions relied on the control of the use of the ligand and the reaction temperature. Our study provides an efficient access to useful polysubstituted indenes and cis-substituted stilbenes, and may offer new means to the development of tandem/domino reactions in a more efficient way. PMID:17217305

  14. Characterization of Reagent Pencils for Deposition of Reagents onto Paper-Based Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Cheyenne H. Liu

    2017-08-01

    Full Text Available Reagent pencils allow for solvent-free deposition of reagents onto paper-based microfluidic devices. The pencils are portable, easy to use, extend the shelf-life of reagents, and offer a platform for customizing diagnostic devices at the point of care. In this work, reagent pencils were characterized by measuring the wear resistance of pencil cores made from polyethylene glycols (PEGs with different molecular weights and incorporating various concentrations of three different reagents using a standard pin abrasion test, as well as by measuring the efficiency of reagent delivery from the pencils to the test zones of paper-based microfluidic devices using absorption spectroscopy and digital image colorimetry. The molecular weight of the PEG, concentration of the reagent, and the molecular weight of the reagent were all found to have an inverse correlation with the wear of the pencil cores, but the amount of reagent delivered to the test zone of a device correlated most strongly with the concentration of the reagent in the pencil core. Up to 49% of the total reagent deposited on a device with a pencil was released into the test zone, compared to 58% for reagents deposited from a solution. The results suggest that reagent pencils can be prepared for a variety of reagents using PEGs with molecular weights in the range of 2000 to 6000 g/mol.

  15. Serum free light chain reference values: a critical approach.

    Science.gov (United States)

    Altinier, Sara; Seguso, Mara; Zaninotto, Martina; Varagnolo, Mariacristina; Adami, Fausto; Angeli, Paolo; Plebani, Mario

    2013-05-01

    The clinical usefulness of serum free light chain (FLC) measurement in the management of patients with plasma cell proliferative disorders has been reported in several papers, and most clinical studies use the reference ranges declared by the manufacturer. The aim of the present study was to evaluate the reproducibility of FLCs immunoassay and to validate the reference range, before introducing it in routine setting. Internal quality control materials and a pool of fresh serum samples were used to evaluate imprecision; 162 fresh sera from healthy blood donors were analyzed to evaluate the reference range for FLCs. In order to verify the κ/λ FLC ratio, 43 sera from patients with polyclonal hypergammaglobulinemia were tested. The FLC immunoassay was performed using a nephelometer with the Freelite reagents. The imprecision studies performed using a serum pool tested with two different lots of reagents showed a mean CV of 16.09% for κFLC and of 16.72% for λFLC. Lower CV%s and different mean values were found by calculating the results from each specific lot separately, while different results were obtained using the control materials provided by the manufacturer. In reference subjects, the 2.5-97.5th percentiles were found to be 4.52-22.33 and 4.84-21.88mg/L for κFLC and λFLC, respectively. The range for κ/λ ratio (0.65-2.36) was validated with the values obtained from subjects with polyclonal hypergammaglobulinemia. In retesting 15 samples from blood donor subjects with a different lot of reagents, mean bias percentages of 17.60 for κFLC and 15.26 for λFLC were obtained. These findings confirm the lot-to-lot variability of the FLC assays also in the measurement of polyclonal light chains, as well as the need to carefully validate the reference values. Published by Elsevier Inc.

  16. Handling Pyrophoric Reagents

    Energy Technology Data Exchange (ETDEWEB)

    Alnajjar, Mikhail S.; Haynie, Todd O.

    2009-08-14

    Pyrophoric reagents are extremely hazardous. Special handling techniques are required to prevent contact with air and the resulting fire. This document provides several methods for working with pyrophoric reagents outside of an inert atmosphere.

  17. 2006 Bethesda International Consensus recommendations on the immunophenotypic analysis of hematolymphoid neoplasia by flow cytometry: optimal reagents and reporting for the flow cytometric diagnosis of hematopoietic neoplasia.

    Science.gov (United States)

    Wood, Brent L; Arroz, Maria; Barnett, David; DiGiuseppe, Joseph; Greig, Bruce; Kussick, Steven J; Oldaker, Teri; Shenkin, Mark; Stone, Elizabeth; Wallace, Paul

    2007-01-01

    Immunophenotyping by flow cytometry has become standard practice in the evaluation and monitoring of patients with hematopoietic neoplasia. However, despite its widespread use, considerable variability continues to exist in the reagents used for evaluation and the format in which results are reported. As part of the 2006 Bethesda Consensus conference, a committee was formed to attempt to define a consensus set of reagents suitable for general use in the diagnosis and monitoring of hematopoietic neoplasms. The committee included laboratory professionals from private, public, and university hospitals as well as large reference laboratories that routinely operate clinical flow cytometry laboratories with an emphasis on lymphoma and leukemia immunophenotyping. A survey of participants successfully identified the cell lineage(s) to be evaluated for each of a variety of specific medical indications and defined a set of consensus reagents suitable for the initial evaluation of each cell lineage. Elements to be included in the reporting of clinical flow cytometric results for leukemia and lymphoma evaluation were also refined and are comprehensively listed. The 2006 Bethesda Consensus conference represents the first successful attempt to define a set of consensus reagents suitable for the initial evaluation of hematopoietic neoplasia. Copyright 2007 Clinical Cytometry Society.

  18. International Laser Ranging Service (ILRS): Terms of Reference

    Science.gov (United States)

    Husson, Van; Noll, Carey

    2000-01-01

    The International Laser Ranging Service (ILRS) is an established Service within Section II , Advanced Space Technology, of the International Association of Geodesy (IAG). The primary objective of the ILRS is to provide a service to support, through Satellite and Lunar Laser Ranging data and related products, geodetic and geophysical research activities as well as International Earth Rotation Service (IERS) products important to the maintenance of an accurate International Terrestrial Reference Frame (ITRF). The service also develops the necessary standards/specifications and encourages international adherence to its conventions.

  19. International Geomagnetic Reference Field: the 12th generation

    DEFF Research Database (Denmark)

    Thébault, Erwan; Finlay, Chris; Beggan, Ciarán D.

    2015-01-01

    The 12th generation of the International Geomagnetic Reference Field (IGRF) was adopted in December 2014 by the Working Group V-MOD appointed by the International Association of Geomagnetism and Aeronomy (IAGA). It updates the previous IGRF generation with a definitive main field model for epoch ...

  20. The International Geomagnetic Reference Field: the twelfth generation

    Science.gov (United States)

    Thebault, Erwan; Finlay, Christopher; The IGRF Working Group

    2015-04-01

    The IGRF is an internationally-agreed reference model of the Earth's magnetic field produced under the auspices of the International Association of Geomagnetism and Aeronomy. The IGRF-12 is the latest update of this well-known model which is used each year by many thousands of users for both industrial and scientific purposes. In October 2014, ten institutions worldwide have made contributions to the IGRF. These models were evaluated and the twelfth generation of the International Geomagnetic Reference Field (IGRF) was adopted in December 2014. In this presentation, we will report on the IGRF activities, briefly describe the candidate models, summarize the evaluation of models performed by different independent teams, show how the IGRF-12 models were calculated and finally discuss some of the main magnetic features of this new model.

  1. Improvements to parallel plate flow chambers to reduce reagent and cellular requirements

    Directory of Open Access Journals (Sweden)

    Larson Richard S

    2001-09-01

    Full Text Available Abstract Background The parallel plate flow chamber has become a mainstay for examination of leukocytes under physiologic flow conditions. Several design modifications have occurred over the years, yet a comparison of these different designs has not been performed. In addition, the reagent requirements of many designs prohibit the study of rare leukocyte populations and require large amounts of reagents. Results In this study, we evaluate modifications to a newer parallel plate flow chamber design in comparison to the original parallel plate flow chamber described by Lawrence et al. We show that modifications in the chamber size, internal tubing diameters, injection valves, and a recirculation design may dramatically reduce the cellular and reagent requirements without altering measurements. Conclusions These modifications are simple and easily implemented so that study of rare leukocyte subsets using scarce or expensive reagents can occur.

  2. Internal-reference solid-electrolyte oxygen sensor

    International Nuclear Information System (INIS)

    Haaland, D.M.

    1977-01-01

    A new solid-electrolyte oxygen sensor has been developed that eliminates the conventional oxygen reference in previous solid-electrolyte oxygen sensor designs and is, therefore, ideally suited as an insertion device for remote oxygen monitoring applications. It is constructed with two cells of stabilized zirconia sealed into a small unit using a new high-temperature platinum-zirconia seal. One electrochemical cell monitors the ratio of oxygen partial pressures inside and outside the sensor while the other solid-electrolyte cell is used for quantitative electrochemical pumping of oxygen. The internal oxygen reference is generated by initially pumping all oxygen out of the known internal volume of the sensor and then quantitatively pumping oxygen back in until oxygen partial pressures are equal inside and out. This information is used with the ideal gas law to calculate oxygen partial pressures. Tests were conducted from 400 to 1000 0 C in mixtures of oxygen and nitrogen spanning approximately 0.2 to 21 percent oxygen concentration range. Sensors with sputtered platinum and porous platinum paste electrodes were compared

  3. International Geomagnetic Reference Field: the 12th generation

    OpenAIRE

    Thébault , Erwan; Finlay , Christopher ,; Beggan , Ciarán ,; Alken , Patrick; Aubert , Julien ,; Barrois , Olivier; Bertrand , François; Bondar , Tatiana; Boness , Axel; Brocco , Laura; Canet , Elisabeth ,; Chambodut , Aude; Chulliat , Arnaud ,; Coïsson , Pierdavide ,; Civet , François

    2015-01-01

    International audience; The 12th generation of the International Geomagnetic Reference Field (IGRF) was adopted in December 2014 by the Working Group V-MOD appointed by the International Association of Geomagnetism and Aeronomy (IAGA). It updates the previous IGRF generation with a definitive main field model for epoch 2010.0, a main field model for epoch 2015.0, and a linear annual predictive secular variation model for 2015.0-2020.0. Here, we present the equations defining the IGRF model, p...

  4. Improved Internal Reference Oxygen Sensors Using Composite Oxides as Electrodes

    DEFF Research Database (Denmark)

    Hu, Qiang

    The thesis describes the research on and development of an internal reference oxygen sensor (IROS). The IROS is potentiometric and uses the equilibrium pO2of the binary mixture of Ni/NiO as the reference pO2. The sensing electrode of the IROS are made from metallic Pt or the composite of (La0.75S...... the application of IROSes are provided. Based on the concepts and fundamentals of the IROS, internal reference sensors that detect other gas species such as hydrogen, chlorine and bromine may be developed.......The thesis describes the research on and development of an internal reference oxygen sensor (IROS). The IROS is potentiometric and uses the equilibrium pO2of the binary mixture of Ni/NiO as the reference pO2. The sensing electrode of the IROS are made from metallic Pt or the composite of (La0.75Sr0...... from 8YSZ is evaluated quantitatively and figures that may be used to design the depletion period of an IROS due to the electronic leak of 8YSZ are provided. One dimensional numerical simulations are performed to study the variation in cell voltage during the process of gas mixing, and the asymmetric...

  5. Oxytetracycline as a new analytical reagent for the spectrophotometric determination of boron

    Energy Technology Data Exchange (ETDEWEB)

    Narayana, G L

    1984-05-01

    Oxytetracycline hydrochloride, Terramycin, is introduced as a new reagent for the spectrophotometric determination of trace quantities of boron in concentrated sulphuric acid medium. The reagent has an absorption maximum at 430 nm, and that of the boron complex at 520 nm. The colored system conformed to Beer's law between 2 and 10 ..mu..g of boron at 520 nm. The molar absorptivity calculated on the basis of boron is 10,800 1 mol/sup -1/ cm/sup -1/. The composition of the complex has been shown to be 1:1 both by the slope ratio and molar ratio methods. 16 references.

  6. Lifetime of the internal reference oxygen sensor

    DEFF Research Database (Denmark)

    Hu, Qiang; Jacobsen, Torben; Hansen, Karin Vels

    2013-01-01

    The internal reference oxygen sensor (IROS) based on a binary mixture of metal and its stoichiometric oxide is subject to leaks that result in consumption of the binary mixture. An IROS loses the functionality when the binary mixture is exhausted. Among the possible leak sources the electronic leak...

  7. 39 CFR 20.1 - International Mail Manual; incorporation by reference.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false International Mail Manual; incorporation by reference. 20.1 Section 20.1 Postal Service UNITED STATES POSTAL SERVICE INTERNATIONAL MAIL INTERNATIONAL... Director of the Federal Register. In conformity with that provision, with 39 U.S.C. 410(b)(1), and as...

  8. 21 CFR 866.3500 - Rickettsia serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rickettsia serological reagents. 866.3500 Section... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3500 Rickettsia serological reagents. (a) Identification. Rickettsia serological reagents are devices that consist of antigens...

  9. 21 CFR 866.3405 - Poliovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Poliovirus serological reagents. 866.3405 Section... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3405 Poliovirus serological reagents. (a) Identification. Poliovirus serological reagents are devices that consist of antigens...

  10. Special issue “International Geomagnetic Reference Field—the twelfth generation”

    DEFF Research Database (Denmark)

    Thébault, E.; Finlay, C. C.; Toh, H.

    2015-01-01

    This special issue of Earth, Planets and Space, synthesizes the efforts made during the construction of the twelfth generation of the International Geomagnetic Reference Field (IGRF-12) that was released online in December 2014 (http://www.ngdc.noaa.gov/IAGA/vmod/ igrf.html). The IGRF-12 is a ser......This special issue of Earth, Planets and Space, synthesizes the efforts made during the construction of the twelfth generation of the International Geomagnetic Reference Field (IGRF-12) that was released online in December 2014 (http://www.ngdc.noaa.gov/IAGA/vmod/ igrf.html). The IGRF-12...

  11. Trifluoromethanesulfonic Anhydride as a Low-Cost and Versatile Trifluoromethylation Reagent.

    Science.gov (United States)

    Ouyang, Yao; Xu, Xiu-Hua; Qing, Feng-Ling

    2018-04-19

    A large number of reagents have been developed for the synthesis of trifluoromethylated compounds. However, an ongoing challenge in trifluoromethylation reaction is the use of less expensive and practical trifluoromethyl sources. We report herein the unprecedented direct trifluoromethylation of (hetero)arenes using trifluoromethanesulfonic anhydride as a radical trifluoromethylation reagent by merging photoredox catalysis and pyridine activation. Furthermore, introduction of both the CF 3 and OTf groups of the trifluoromethanesulfonic anhydride into internal alkynes to access tetrasubstituted trifluoromethylated alkenes was achieved. Since trifluoromethanesulfonic anhydride is a low-cost and abundant chemical, this method provides a cost-efficient and practical route to trifluoromethylated compounds. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)

    Science.gov (United States)

    Brand, Willi A.; Coplen, Tyler B.; Vogl, Jochen; Rosner, Martin; Prohaska, Thomas

    2014-01-01

    Since the early 1950s, the number of international measurement standards for anchoring stable isotope delta scales has mushroomed from 3 to more than 30, expanding to more than 25 chemical elements. With the development of new instrumentation, along with new and improved measurement procedures for studying naturally occurring isotopic abundance variations in natural and technical samples, the number of internationally distributed, secondary isotopic reference materials with a specified delta value has blossomed in the last six decades to more than 150 materials. More than half of these isotopic reference materials were produced for isotope-delta measurements of seven elements: H, Li, B, C, N, O, and S. The number of isotopic reference materials for other, heavier elements has grown considerably over the last decade. Nevertheless, even primary international measurement standards for isotope-delta measurements are still needed for some elements, including Mg, Fe, Te, Sb, Mo, and Ge. It is recommended that authors publish the delta values of internationally distributed, secondary isotopic reference materials that were used for anchoring their measurement results to the respective primary stable isotope scale.

  13. The International Reference Ionosphere 2012 – a model of international collaboration

    Czech Academy of Sciences Publication Activity Database

    Bilitza, D.; Altadill, D.; Zhang, Y.; Mertens, Ch.; Truhlík, Vladimír; Richards, P.; McKinnell, L.- A.; Reinisch, B.

    2014-01-01

    Roč. 4, 20 February (2014), A07/1-A07/12 ISSN 2115-7251 R&D Projects: GA MŠk(CZ) LH11123 Institutional support: RVO:68378289 Keywords : International Reference Ionosphere * empirical models * plasma parameters * real - time IRI Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 2.558, year: 2014 http://www.swsc-journal.org/articles/swsc/abs/2014/01/swsc130043/swsc130043.html

  14. Diagnostic reagent system

    International Nuclear Information System (INIS)

    1976-01-01

    A solid phase reagent for use in radioimmunoassay of antigens and antibodies is described. The reagent is prepared by mixing specific antibody or radiolabeled antigen with polyethylene glycol (4000-6000) and gamma globulin in a buffer at pH 4-10 and lyophilizing, the antigens being thyroxine, triiodothyronine, digoxin and digitoxin (1-1000 μCi 125 I/μg). The buffer consists of a 0.08 molar sodium barbital solution containing 0.1% of ox-serum albumin and 0.35% of 8-anilino-1-naftalene sulfonic acid

  15. 21 CFR 866.3350 - Leptospira spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Leptospira spp. serological reagents. 866.3350... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3350 Leptospira spp. serological reagents. (a) Identification. Leptospira spp. serological reagents are devices that...

  16. 21 CFR 866.3200 - Echinococcus spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Echinococcus spp. serological reagents. 866.3200... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3200 Echinococcus spp. serological reagents. (a) Identification. Echinococcus spp. serological reagents are devices that...

  17. 21 CFR 866.3415 - Pseudomonas spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pseudomonas spp. serological reagents. 866.3415... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3415 Pseudomonas spp. serological reagents. (a) Identification. Pseudomonas spp. serological reagents are devices that...

  18. Improved Internal Reference Oxygen Sensors with Composite Ceramic Electrodes

    DEFF Research Database (Denmark)

    Hu, Qiang; Jacobsen, Torben; Hansen, Karin Vels

    2012-01-01

    Potentiometric oxygen sensors with an internal reference electrode, which uses the equilibrium pO2 of the binary mixture of Ni/NiO as the reference, are demonstrated. The cells employ Pt or composite ceramics as the sensing electrode. The cells are fabricated by a flexible and potentially low cost...... and performance are highly reproducible. The composite ceramics, based on strontium doped manganite and yttria doped zirconia, are proven superior over Pt to serve as the electrode material....

  19. Real-time isothermal RNA amplification of toxic marine microalgae using preserved reagents on an integrated microfluidic platform.

    Science.gov (United States)

    Tsaloglou, Maria-Nefeli; Laouenan, Florian; Loukas, Christos-Moritz; Monsalve, Lisandro Gabriel; Thanner, Christine; Morgan, Hywel; Ruano-López, Jesus M; Mowlem, Matthew C

    2013-01-21

    Quantitation of specific RNA sequences is a useful technique in marine biology that can elucidate cell abundance, speciation and viability, especially for early detection of harmful algal blooms. We are thus developing an integrated microfluidic system for cell concentration and lysis, RNA extraction/purification and quantitative RNA detection for environmental applications. The portable system is based on a microfluidic cartridge, or "lab-card", using a low-cost injection moulded device, with a laminated lid. Here we present real-time isothermal RNA amplification using reagent master-mixes preserved on-chip in a gel at 4 °C for up to eight months. We demonstrate quantitation by reference to an internal control in a competitive assay with 500 cell equivalents of the toxic microalga Karenia brevis. Annealing of primers, amplification at 41 °C and real-time fluorescence detection of the internal control and target using sequence-specific molecular beacons were all performed on-chip.

  20. Production of reagents for cleaning fluids

    Energy Technology Data Exchange (ETDEWEB)

    Grunberg, I V; Korostyleva, R N; Pytel, S P; Spasskii, P I; Titarenko, N K; Trachtenberg, S I; Yushkevich, V I

    1980-10-25

    A method for producing reagents for cleaning fluids is proposed using polymerization of acrylonitril, metachrylate or a mixture of the two in water and saponification of the polymers with alakali. To reduce the consumption of monomers and increase the quality of the reagents, 0.4-1.0 parts humic substances, 0.2-1.0 parts hydrolizate from tanning waste products and 1.2-4.0 parts monomers are added to the reaction medium, followed by copolymerization in an acid medium. The proposed method ensures quality reagents which combine lower water yield with a moderate increase in viscosity when acting on clay solutions. Compared with the current method, this method lowers the consumption of an expensive and hard-to-find monomer 1.2-1.4X for one ton of reagent, which lowers the cost of raw material by 1.3-1.7X. This results in a savings of 195-385 rubles per ton of reagent, 600-1200 thousand at 3000 tons/yr.

  1. A reagent for processing drilling muds

    Energy Technology Data Exchange (ETDEWEB)

    Polyakov, G.A.; Khon-Pak, A.T.; Khon, A.V.; Normatov, L.N.; Telegin, B.V.

    1983-01-01

    A reagent is proposed for processing drilling muds. It contains an acrylic polymer and potassium permanganate. The reagent is distinguished by the fact that in order to improve the quality of the drilling muds by increasing their salt resistance, the reagent contains hydrolized nitron fiber as the acrylic polymer with the following component relationship (in percent by weight): potassium permanganate, 0.015 to 0.065 and hydrolyzed nitron fiber, the remainder.

  2. Fast biosensor with reagent layer

    NARCIS (Netherlands)

    2008-01-01

    A detection system and a sensor chip for detecting target mols., and thus corresponding analytes in a sample is described. Typically the detection system includes a sensor chip. The sensor chip (1) comprises on its detection surface a dissolvable reagent layer. When the dissolvable reagent layer is

  3. Selective-Reagent-Ionization Mass Spectrometry: New Prospects for Atmospheric Research

    Science.gov (United States)

    Sulzer, Philipp; Jordan, Alfons; Hartungen, Eugen; Hanel, Gernot; Jürschik, Simone; Herbig, Jens; Märk, Lukas; Märk, Tilmann D.

    2014-05-01

    -MS developments, which include TOF based instruments with increased sensitivity of one order of magnitude (i.e. in the 103 cps/ppbv regime) by means of using a quadrupole ion guide between the drift tube and the TOF analyzer. It is expected that these developments will have a serious impact in atmospheric research, because increased sensitivity implies reduced measurement times and thus, e.g. even more accurate flux measurements. References [1] J. de Gouw, C. Warneke, T. Karl, G. Eerdekens, C. van der Veen, R. Fall, Mass Spectrometry Reviews, 26 (2007), 223-257. [2] A. Jordan, S. Haidacher, G. Hanel, E. Hartungen, J. Herbig, L. Märk, R. Schottkowsky, H. Seehauser, P. Sulzer, T.D. Märk, International Journal of Mass Spectrometry, 286 (2009), 32 - 38. [3] T. Karl, A. Hansel, L. Cappellin, L. Kaser, I. Herdlinger-Blatt, W. Jud, Atmospheric Chemistry and Physics, 12/24 (2012), 11877-11884. [4] P. Sulzer, A. Edtbauer, E. Hartungen, S. Juerschik, A. Jordan, G. Hanel, S. Feil, S. Jaksch, L. Märk, T.D. Märk, International Journal of Mass Spectrometry, 321 (2012), 66-70. Acknowledgement We acknowledge financial support by the Austrian Research Promotion Agency (FFG), Wien.

  4. 21 CFR 864.8100 - Bothrops atrox reagent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bothrops atrox reagent. 864.8100 Section 864.8100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8100 Bothrops atrox reagent. (a...

  5. Two-reagent neutralization scheme for controlling the migration of contaminants from a uranium mill tailings disposal pond

    International Nuclear Information System (INIS)

    Dodson, M.E.; Opitz, B.E.; Sherwood, D.R.

    1984-11-01

    Techniques for reducing contaminant migration from tailings liquor impoundments and evaporation ponds are being investigated by the Pacific Northwest Laboratory as part of the Nuclear Regulatory Commission's Uranium Research and Recovery Program. Building upon previous studies investigating single-reagent neutralization, laboratory experiments were conducted to evaluate the performance of a two-reagent neutralization scheme for the treatment of acidic uranium mill tailings liquors. Acidic tailings liquor, pH 3 neutralization to pH 4.0 followed by continued neutralization with lime to pH 7.3, resulted in the highest solution quality with respect to the Environmental Protection Agency's water quality guidelines. Furthermore, the two-reagent neutralization scheme is the most cost-effective treatment procedure tested to date. 13 references, 1 table

  6. [International reference prices and cost minimization analysis for the regulation of medicine prices in Colombia].

    Science.gov (United States)

    Vacca, Caludia; Acosta, Angela; Rodriguez, Ivan

    2011-01-01

    To suggest a scheme of decision making on pricing for medicines that are part of Free Regulated Regime, a regulation way of the pharmaceutical pricing policy in Colombia. It includes two regulation tools: international reference prices and a cost minimization analysis methodology. Following the current pricing policy, international reference prices were built with data from five countries for selected medicines, which are under Free Regulated Regime. The cost minimization analysis methodology includes selection of those medicines under Free Regulated Regime with possible comparable medicines, selection of comparable medicines, and treatment costs evaluation. As a result of the estimate of International Reference Prices, four medicines showed in the domestic pharmaceutical market a bigger price than the Reference Price. A scheme of decision-making was design containing two possible regulation tools for medicines that are part of Free Regulated Regime: estimate of international reference prices and cost minimization analysis methodology. This diagram would be useful to assist the pricing regulation of Free Regulated Regime in Colombia. As present results shows, international reference prices make clear when domestic prices are higher than those of reference countries. In the current regulation of pharmaceutical prices in Colombia, the international reference price has been applied for four medicines. Would be suitable to extend this methodology to other medicines of high impact on the pharmaceutical expenditure, in particular those covered by public funding. The availability of primary sources about treatment costs in Colombia needs to be improved as a requirement to develop pharmaco-economic evidence. SISMED is an official database that represents an important primary source of medicines prices in Colombia. Nevertheless, having into account that SISMED represents an important advantage of transparency in medicines prices, it needs to be improved in quality and data

  7. Development of national immunoassay reagent programmes

    International Nuclear Information System (INIS)

    Sufi, S.B.; Micallef, J.V.; Ahsan, R.; Goncharov, N.P.

    1992-01-01

    Despite the existence of networks of fully equipped laboratories with well-trained staff, the availability of immunodiagnostic services in developing countries is often limited by the high cost of imported kits. There are a number of ways of tackling this problem, ranging from bulk purchase of kits or reagents to local development and production of assay systems. Argentina/Chile, China, Cuba/Mexico, and Thailand are amongst the countries which have established local immunoassay reagent programmes to manufacture low cost, high quality immunoassay reagents. Kits from these projects are now beginning to become available, and it is hoped that they will promote national diagnostic services and research, as well as stimulating the development of reagent programmes for other analytes. (author). 4 refs, 1 tab

  8. Reactivity of lignin and problems of its oxidative destruction with peroxy reagents

    International Nuclear Information System (INIS)

    Demin, Valerii A; Shereshovets, Valerii V; Monakov, Yurii B

    1999-01-01

    Published data on reactivity and oxidation of lignin and model compounds with hydrogen peroxide, ozone and chlorine dioxide as well as on oxidative destruction of the sulfate pulp lignin with various reagents during bleaching are systematised and generalised. Concepts of lignin activation towards its selective oxidation and kinetic features of sulfate pulp oxidative delignification are considered. The bibliography includes 157 references.

  9. A review of the kinetics of oxidation and reduction of sale-free reagents in the U/Pu separation process

    International Nuclear Information System (INIS)

    Li Sa; Ouyang Yinggen; Gao Yaobin

    2012-01-01

    Background: Recently, the most reductant widely used to partition plutonium from uranium in the Purex solvent extraction purification process have been salt-free reagents. Purpose: In order to determine the utility of sale-free reagents in the Purex solvent extraction process. Methods: The report is a review of the applications of sale-free reagents in the U/Pu separation process, such as hydroxylamine derivative, U(IV), aldehyde derivative, hydrazine, hydroxyl carbamide, derivative, hydroxamic acid and so on. Results: In this review, we have investigated and summarized the previous works covering the thermodynamics and dynamics behaviors to offer references for the future R and D works on the capability of salt-free reagents in the PUREX process and to indicate its applications. Conclusions: Acetohydroxamic acid and hydroxysemicarbazide have the capability of stripping trace amount plutonium of uranium in the future industrialization. (authors)

  10. 21 CFR 866.3720 - Streptococcus spp. exo-enzyme reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Streptococcus spp. exo-enzyme reagents. 866.3720... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3720 Streptococcus spp. exo-enzyme reagents. (a) Identification. Streptococcus spp. exoenzyme reagents are devices used...

  11. Inactivation of rabies diagnostic reagents by gamma radiation

    International Nuclear Information System (INIS)

    Gamble, W.C.; Chappell, W.A.; George, E.H.

    1980-01-01

    Treatment of CVS-11 rabies adsorbing suspensions and street rabies infected mouse brains with gamma radiation resulted in inactivated reagents that are safer to distribute and use. These irradiated reagents were as sensitive and reactive as the nonirradiated control reagents

  12. 21 CFR 866.3255 - Escherichia coli serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Escherichia coli serological reagents. 866.3255... coli serological reagents. (a) Identification. Escherichia coli serological reagents are devices that consist of antigens and antisera used in serological tests to identify Escherichia coli from cultured...

  13. Gas sensor with multiple internal reference electrodes and sensing electrodes

    DEFF Research Database (Denmark)

    2016-01-01

    The invention relates to a potentiometric gas sensor, or potentiometric gas detection element, with multiple internal reference electrodes and multiple sensing electrodes for determining the concentrations of gas components in a gaseous mixture. The sensor for gas detection comprises: a solid...

  14. The prothrombin time/international normalised ratio (PT/INR) line: derivation of local INR with commercial thromboplastins and coagulometers – two independent studies

    DEFF Research Database (Denmark)

    Poller, Leon; Ibrahim, S.; Keown, M.

    2011-01-01

    reagents, and from 7.0% to 2.6% with rabbit reagents. In the second study, deviation was reduced from 11.2% to 0.4% with human reagents by both local ISI calibration and the PT/INR Line. With rabbit reagents, 10.4% deviation was reduced to 1.1% with both procedures; 4.9% deviation was reduced to 0.5......Background: The WHO scheme for prothrombin time (PT) standardization has been limited in application, because of its difficulties in implementation, particularly the need for mandatory manual PT testing and for local provision of thromboplastin international reference preparations (IRP). Methods...... thromboplastins and coagulometers. INRs were compared with manual certified values with thromboplastin IRP from expert centres and in the second study also with INRs from local ISI calibrations. Results: In the first study with the PT/INR Line, 8.7% deviation from certified INRs was reduced to 1.1% with human...

  15. 21 CFR 864.8540 - Red cell lysing reagent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Red cell lysing reagent. 864.8540 Section 864.8540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8540 Red cell lysing reagent...

  16. ANÁLISE DA DEGRADAÇÃO DE REAGENTES QUÍMICOS DE USO ACADÊMICO POR ESPECTROSCOPIA NO INFRAVERMELHO FTIR-UATR

    Directory of Open Access Journals (Sweden)

    Herbert Leite Souza

    2017-01-01

    Full Text Available No meio acadêmico é comum a utilização de alguns reagentes com o prazo de validade fora do indicado pelo fabricante. Neste trabalho foram analisados reagentes no prazo de validade e após o prazo de validade coletados em laboratórios químicos, com intuito da criação de dados que comprovem a degradação gradativa dos mesmos após o vencimento da data prevista pelo fabricante, e quantificar a perda de pureza do reagente. Foi utilizada a técnica de espectroscopia no infravermelho FTIR-UATR e calculado as áreas de uma banda de referência para obtenção da porcentagem de degradação. Apesar do comportamento variado de cada reagente, as análises comprovaram que, numa visão geram, o uso de reagentes vencidos no meio acadêmico não representa grandes alterações nos produtos obtidos em reações químicas, pelo contrário pode representar uma economia financeira substancial.

  17. 21 CFR 660.30 - Reagent Red Blood Cells.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Reagent Red Blood Cells. 660.30 Section 660.30...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.30 Reagent Red Blood Cells. (a) Proper name and definition. The proper name of the product shall be...

  18. The International Reference Ionosphere 2012 – a model of international collaboration☆

    Directory of Open Access Journals (Sweden)

    Bilitza Dieter

    2014-02-01

    Full Text Available The International Reference Ionosphere (IRI project was established jointly by the Committee on Space Research (COSPAR and the International Union of Radio Science (URSI in the late sixties with the goal to develop an international standard for the specification of plasma parameters in the Earth’s ionosphere. COSPAR needed such a specification for the evaluation of environmental effects on spacecraft and experiments in space, and URSI for radiowave propagation studies and applications. At the request of COSPAR and URSI, IRI was developed as a data-based model to avoid the uncertainty of theory-based models which are only as good as the evolving theoretical understanding. Being based on most of the available and reliable observations of the ionospheric plasma from the ground and from space, IRI describes monthly averages of electron density, electron temperature, ion temperature, ion composition, and several additional parameters in the altitude range from 60 km to 2000 km. A working group of about 50 international ionospheric experts is in charge of developing and improving the IRI model. Over time as new data became available and new modeling techniques emerged, steadily improved editions of the IRI model have been published. This paper gives a brief history of the IRI project and describes the latest version of the model, IRI-2012. It also briefly discusses efforts to develop a real-time IRI model. The IRI homepage is at http://IRImodel.org.

  19. The role of internal reference prices in consumers' willingness to pay judgments: Thaler's Beer Pricing Task revisited.

    Science.gov (United States)

    Ranyard, R; Charlton, J P; Williamson, J

    2001-02-01

    Alternative reference prices, either displayed in the environment (external) or recalled from memory (internal) are known to influence consumer judgments and decisions. In one line of previous research, internal reference prices have been defined in terms of general price expectations. However, Thaler (Marketing Science 4 (1985) 199; Journal of Behavioral Decision Making 12 (1999) 183) defined them as fair prices expected from specific types of seller. Using a Beer Pricing Task, he found that seller context had a substantial effect on willingness to pay, and concluded that this was due to specific internal reference prices evoked by specific contexts. In a think aloud study using the same task (N = 48), we found only a marginal effect of seller context. In a second study using the Beer Pricing Task and seven analogous ones (N = 144), general internal reference prices were estimated by asking people what they normally paid for various commodities. Both general internal reference prices and seller context influenced willingness to pay, although the effect of the latter was again rather small. We conclude that general internal reference prices have a greater impact in these scenarios than specific ones, because of the lower cognitive load involved in their storage and retrieval.

  20. Absorbed Internal Dose Conversion Coefficients for Domestic Reference Animals and Plant

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Choi, Yong Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-02-15

    This paper describes the methodology of calculating the internal dose conversion coefficient in order to assess the radiological impact on non-human species. This paper also presents the internal dose conversion coefficients of 25 radionuclides ({sup 3}H, {sup 7}Be, {sup 14}C, {sup 40}K, {sup 51}Cr, {sup 54}Mn, {sup 59}Fe, {sup 58}Co, {sup 60}Co, {sup 65}Zn, {sup 90}Sr, '9{sup 5}Zr, {sup 95}Nb, {sup 99}Tc, {sup 106}Ru, {sup 129}I, {sup 131}I, {sup 136}Cs, {sup 137}Cs, {sup 140}Ba, {sup 140}La, {sup 144}Ce, {sup 238}U, {sup 239}Pu, {sup 240}Pu) for domestic seven reference animals (roe deer, rat, frog, snake, Chinese minnow, bee, and earthworm) and one reference plant (pine tree). The uniform isotropic model was applied in order to calculate the internal dose conversion coefficients. The calculated internal dose conversion coefficient (muGyd{sup -1} per Bqkg{sup -1}) ranged from 10{sup -6} to 10{sup -2} according to the type of radionuclides and organisms studied. It turns out that the internal does conversion coefficient was higher for alpha radionuclides, such as {sup 238}U, {sup 239}Pu, and {sup 240}Pu, and for large organisms, such as roe deer and pine tree. The internal dose conversion coefficients of {sup 239}Pu, {sup 240}Pu, {sup 238}U, {sup 14}C, {sup 3}H and {sup 99}Tc were independent of the organism

  1. Special issue “International Geomagnetic Reference Field—the twelfth generation”

    OpenAIRE

    Thébault, E.; Finlay, C. C.; Toh, H.

    2015-01-01

    This special issue of Earth, Planets and Space, synthesizes the efforts made during the construction of the twelfth generation of the International Geomagnetic Reference Field (IGRF-12) that was released online in December 2014 (http://www.ngdc.noaa.gov/IAGA/vmod/ igrf.html). The IGRF-12 is a series of standard mathematical models describing the large scale internal part of the Earth’s magnetic field between epochs 1900.0 and 2015.0 with a forecast to epoch 2020.0. This activity has been main...

  2. [An evaluation of the China-made HIV antibody test reagents].

    Science.gov (United States)

    Zheng, X W; Zhu, D

    1990-06-01

    This paper reports the results of the evaluation of the China-made HIV antibody screening test reagents, including the IF and IE reagents prepared by the Institute of Virology, CAPM, the ELISA reagent prepared by the Shanghai Institute of Biological Products. Based on the results, the sensitivities of the IF and IE are from 91.2% to 96.9%; the specificities, from 94.6% to 97.3%. Due to the low HIV prevalence in China, the predictive values of negative of these reagents are up to 100%; but the predictive values of positive are very low. It is suggested that these reagents can be used for HIV antibody screen testing in China. The package of some reagents should be improved, the price of some reagents should be decreased.

  3. Spectrophotometric determination of tannins by phosphotungstic-phosphomolybdic reagent

    Energy Technology Data Exchange (ETDEWEB)

    Reicher, F; Sierakowski, M R; Correa, J B.C. [Parana Univ., Curitiba (Brazil). Dept. de Bioquimica

    1981-01-01

    There are several colorimetric techniques to determine tannins in plant extracts. One frequently used is the Folin method (phosphotungstic acid reagent) that procedures a blue color with phenolic compounds. However, this coloured complex is unstable. With the Folin-Ciocalteau reagent, used in protein determination (Lowry et al. J.B.C. 193: 265, 1951) good results were obtained, even in the absence of cooper solution. Using phosphotungstic-phosphomolybdic reagent (Folin-Denis), it was obtained maximum color with 1,0 ml of the reagent in 20 minutes, after the additon of 10 ml 20% sodium carbonate solution. Tannins samples containing 10 to 200 ..mu..g/ml were analysed. Absorbances are determined at 720 or 600 nm. Tannins of commercial preparations from Acacia negra were analysed by the phosphotungstic-phosphomolybdic reagent before (A) and after (B) treatment with chromate hyde powder. By this procedure hydrolysible tannins were determined (A-B).

  4. Spectrophotometric determination of tannins by phosphotungstic-phosphomolibdic reagent

    International Nuclear Information System (INIS)

    Reicher, F.; Sierakowski, M.R.; Correa, J.B.C.

    1981-01-01

    There are several colorimetric techniques to determine tannins in plant extracts. One frequently used is the Folin method (phosphotungstic acid reagent) that procedures a blue color with phenolic compounds. However, this coloured complex is unstable. With the Folin-Ciocalteau reagent, used in protein determination (Lowry et al. J.B.C. 193: 265, 1951) good results were obtained, even in the absence of cooper solution. Using phosphotungstic-phosphomolibdic reagent (Folin-Denis), it was obtained maximum color with 1,0 ml of the reagent in 20 minutes, after the adition of 10 ml 20% sodium carbonate solution. Tannins samples containing 10 to 200 μg/ml were analysed. Absorbances are determined at 720 or 600 nm. Tannins of commercial preparations from Acacia negra were analysed by the phosphotungstic-phosphomolibdic reagent before (A) and after (B) treatment with chromate hyde powder. By this procedure hydrolysible tannins were determined (A-B). (Author) [pt

  5. Constructing New Bioorthogonal Reagents and Reactions.

    Science.gov (United States)

    Row, R David; Prescher, Jennifer A

    2018-05-15

    Chemical tools are transforming our understanding of biomolecules and living systems. Included in this group are bioorthogonal reagents-functional groups that are inert to most biological species, but can be selectively ligated with complementary probes, even in live cells and whole organisms. Applications of these tools have revealed fundamental new insights into biomolecule structure and function-information often beyond the reach of genetic approaches. In many cases, the knowledge gained from bioorthogonal probes has enabled new questions to be asked and innovative research to be pursued. Thus, the continued development and application of these tools promises to both refine our view of biological systems and facilitate new discoveries. Despite decades of achievements in bioorthogonal chemistry, limitations remain. Several reagents are too large or insufficiently stable for use in cellular environments. Many bioorthogonal groups also cross-react with one another, restricting them to singular tasks. In this Account, we describe our work to address some of the voids in the bioorthogonal toolbox. Our efforts to date have focused on small reagents with a high degree of tunability: cyclopropenes, triazines, and cyclopropenones. These motifs react selectively with complementary reagents, and their unique features are enabling new pursuits in biology. The Account is organized by common themes that emerged in our development of novel bioorthogonal reagents and reactions. First, natural product structures can serve as valuable starting points for probe design. Cyclopropene, triazine, and cyclopropenone motifs are all found in natural products, suggesting that they would be metabolically stable and compatible with a variety of living systems. Second, fine-tuning bioorthogonal reagents is essential for their successful translation to biological systems. Different applications demand different types of probes; thus, generating a collection of tools that span a continuum of

  6. The Role of Internal Reference Points in the Category Purchase Decision.

    OpenAIRE

    Bell, David R; Bucklin, Randolph E

    1999-01-01

    The authors study the role that reference effects play in the category purchase decision for consumer nondurable products. Category purchase behavior is represented by a nested logit model that is estimated on purchase records of shoppers in two Universal Product Code (UPC) scanner panels. A series of hypotheses are developed, modeled, and tested regarding the effects that internal reference points for product category attractiveness are likely to have on the decision to buy in a product cate...

  7. 21 CFR 866.3220 - Entamoeba histolytica serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3220... fluorescent dye (immunofluorescent reagents) used to identify Entamoeba histolytica directly from clinical...

  8. Reagent-loaded plastic microfluidic chips for detecting homocysteine

    International Nuclear Information System (INIS)

    Suk, Ji Won; Jang, Jae-Young; Cho, Jun-Hyeong

    2008-01-01

    This report describes the preliminary study on plastic microfluidic chips with pre-loaded reagents for detecting homocysteine (Hcy). All reagents needed in an Hcy immunoassay were included in a microfluidic chip to remove tedious assay steps. A simple and cost-effective bonding method was developed to realize reagent-loaded microfluidic chips. This technique uses an intermediate layer between two plastic substrates by selectively patterning polydimethylsiloxane (PDMS) on the embossed surface of microchannels and fixing the substrates under pressure. Using this bonding method, the competitive immunoassay for SAH, a converted form of Hcy, was performed without any damage to reagents in chips, and the results showed that the fluorescent signal from antibody antigen binding decreased as the SAH concentration increased. Based on the SAH immunoassay, whole immunoassay steps for Hcy detection were carried out in plastic microfluidic chips with all necessary reagents. These experiments demonstrated the feasibility of the Hcy immunoassay in microfluidic devices

  9. 21 CFR 866.3375 - Mycoplasma spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3375 Mycoplasma... fluorescent dye (immunofluorescent reagents) used to identify Mycoplasma spp. directly from clinical specimens...

  10. 21 CFR 866.3780 - Toxoplasma gondii serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3780 Toxoplasma... (immunofluorescent reagents) used to identify Toxoplasma gondii from clinical specimens. The identification aids in...

  11. Effect of reagent charge on the labeling of erythrocyte membrane proteins by photoactivated reagents

    International Nuclear Information System (INIS)

    Schaeffer, J.C.; Hakimian, R.; Shimer, M.L.

    1986-01-01

    Leaky erythrocyte ghosts were labeled with 3 H-[2-(4-azido-2-nitroanilino)ethyl]trimethylammonium iodide (cationic label) or 3 H-N-(4-azido-2-nitrophenyl)-β-alanine (anionic label). After the membranes were thoroughly washed, seven times as much cationic label was associated with the membranes as anionic label at 5 μM, whereas at 50 μM the cationic label was favored 15-fold. The distribution of label in the membrane proteins was ascertain by SDS-gel electrophoresis followed by autoradiography. At 50 μM cationic label, erythrocyte membrane protein bands 1,2,3,4.2, and 5 were intensely labeled, while band 6 was labeled weakly. At 5 μM cationic label, bands 1 and 4.2 were heavily labeled, while 2,3 and 5 were labeled less well. At both 50 μM and 5 μM anionic label, bands 1 and 6 were most prominently labeled. Bands 2,3,4.2 and 5 were labeled also at 50 μM, but they were labeled only very weakly at 5 μM. Band 4.1 was labeled very poorly if at all by either reagent. A mixture of the reagents gave an additive pattern. Thus, the charge and concentration of these reagents appear to play a major role in their ability to label membrane proteins indiscriminately. Because these reagents contain the same chromophore, 4-azido-2-nitroaniline, and differ mainly only in their charge, they may prove useful in assessing the location of charged sites on proteins in supramolecular complexes

  12. The International Celestial Reference Frame (ICRF) and the Relationship Between Frames

    Science.gov (United States)

    Ma, Chopo

    2000-01-01

    The International Celestial Reference Frame (ICRF), a catalog of VLBI source positions, is now the basis for astrometry and geodesy. Its construction and extension/maintenance will be discussed as well as the relationship of the ICRF, ITRF, and EOP/nutation.

  13. Improved multiple displacement amplification (iMDA) and ultraclean reagents.

    Science.gov (United States)

    Motley, S Timothy; Picuri, John M; Crowder, Chris D; Minich, Jeremiah J; Hofstadler, Steven A; Eshoo, Mark W

    2014-06-06

    Next-generation sequencing sample preparation requires nanogram to microgram quantities of DNA; however, many relevant samples are comprised of only a few cells. Genomic analysis of these samples requires a whole genome amplification method that is unbiased and free of exogenous DNA contamination. To address these challenges we have developed protocols for the production of DNA-free consumables including reagents and have improved upon multiple displacement amplification (iMDA). A specialized ethylene oxide treatment was developed that renders free DNA and DNA present within Gram positive bacterial cells undetectable by qPCR. To reduce DNA contamination in amplification reagents, a combination of ion exchange chromatography, filtration, and lot testing protocols were developed. Our multiple displacement amplification protocol employs a second strand-displacing DNA polymerase, improved buffers, improved reaction conditions and DNA free reagents. The iMDA protocol, when used in combination with DNA-free laboratory consumables and reagents, significantly improved efficiency and accuracy of amplification and sequencing of specimens with moderate to low levels of DNA. The sensitivity and specificity of sequencing of amplified DNA prepared using iMDA was compared to that of DNA obtained with two commercial whole genome amplification kits using 10 fg (~1-2 bacterial cells worth) of bacterial genomic DNA as a template. Analysis showed >99% of the iMDA reads mapped to the template organism whereas only 0.02% of the reads from the commercial kits mapped to the template. To assess the ability of iMDA to achieve balanced genomic coverage, a non-stochastic amount of bacterial genomic DNA (1 pg) was amplified and sequenced, and data obtained were compared to sequencing data obtained directly from genomic DNA. The iMDA DNA and genomic DNA sequencing had comparable coverage 99.98% of the reference genome at ≥1X coverage and 99.9% at ≥5X coverage while maintaining both balance

  14. 21 CFR 864.4020 - Analyte specific reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Analyte specific reagents. 864.4020 Section 864.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Specimen Preparation Reagents § 864.4020 Analyte specific...

  15. 21 CFR 864.4010 - General purpose reagent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false General purpose reagent. 864.4010 Section 864.4010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Specimen Preparation Reagents § 864.4010 General purpose...

  16. Preface: The International Reference Ionosphere (IRI) at equatorial latitudes

    Science.gov (United States)

    Reinisch, Bodo; Bilitza, Dieter

    2017-07-01

    This issue of Advances in Space Research includes papers that report and discuss improvements of the International Reference Ionosphere (IRI). IRI is the international standard for the representation of the plasma in Earth's ionosphere and recognized as such by the Committee on Space Research (COSPAR), the International Union of Radio Science (URSI), the International Telecommunication Union (ITU), and the International Standardization Organization (ISO). As requested, particularly by COSPAR and URSI, IRI is an empirical model relying on most of the available and reliable ground and space observations of the ionosphere. As new data become available and as older data sources are fully exploited the IRI model undergoes improvement cycles to stay as close to the existing data record as possible. The latest episode of this process is documented in the papers included in this issue using data from the worldwide network of ionosondes, from a few of the incoherent scatter radars, from the Alouette and ISIS topside sounders, and from the Global Navigation Satellite Systems (GNSS). The focus of this issue is on the equatorial and low latitude region that is of special importance for ionospheric physics because it includes the largest densities and steep density gradients in the double hump latitudinal structure, the Equatorial Ionization Anomaly (EIA), which is characteristic for this region.

  17. Method for controlled introduction of reagent into a liquid

    Energy Technology Data Exchange (ETDEWEB)

    Newlove, J.C.; McDougall, L.A.

    1988-11-29

    It is an object of this invention to provide a method for using an article to enhance the production of hydrocarbons from geological reservoirs, more particularly from fractured formations. It is an additional object to devise a method for providing controlled release of a reagent downhole, in a pipeline, or in other oil-containing environments or fluids. Thus, there is provided a method for releasing a treating reagent, such as a wax crystal modifier, scale inhibitor, demulsifier, corrosion inhibitor, antioxidant, and biocide, into a liquid hydrocarbon stream. A plurality of porous, substantially wax-free, plastic particles having a softening point above 60/sup 0/C and being chemically resistant to the hydrocarbon stream are placed in the stream. The said particles contain the treating reagent in their pores, said reagent being insoluble in water and in the particles and being leachable on contact with the stream. The hydrocarbon stream is then flowed past said particles and the reagent is leached from the particle pores. In a specific aspect of this invention, a method is provided for recovering crude oil from an underground formation by means of: depositing the aforementioned particles, containing a suitable reagent, downhole in the oil-producing region of the formation; flowing the oil through the deposited particles, thereby leaching the reagent into the oil; and recovering the oil modified by the presence of an active amount of said reagent. Experiments are described to illustrate ways of producing the polymeric particles of the invention and to illustrate the processes of the invention.

  18. Industrial detergent wastewater treatment via fenton reagent

    International Nuclear Information System (INIS)

    Mohd Zairie Mohd Yusuff; Mohd Zulkifli Mohamad Noor; Izirwan Izhab

    2010-01-01

    Production of detergent can generates wastewater containing an organic matter with will consume an oxidation demand, surfactants, suspended solids, fat and oil. Besides, sulfate concentration is high in the most detergent plant effluent because of the sulphonation process that has physiological and toxic effects on marine organisms. Therefore, a research must be conducted to find the solution for this problem. The feasibility of Fentons reagent to treat detergent waste was investigated in this study. The sample of detergent wastewater was taken from FPG Oleo chemicals Sdn. Bhd. This experiment studied the effect of temperature towards the feasibility of Fentons reagent process besides the dosage between hydrogen peroxide (H 2 O 2 ) and ferrous ion (Fe 2+ ) in the reagent. While, evaluated efficiency of Fentons reagent in term of chemical oxygen demand (COD), total suspended solid (TSS) and the turbidity reduction within the experimental design. The result found that overall removal was achieved until 96.2 % in term of COD, 98.1 % in term of TSS and 99.6 % in term of turbidity using Fentons reagent process. Besides, also found that this process is optimum at temperature 35 degree Celsius are able to achieve the Standard A of Parameter Limit of Effluent of Standard A and Standard B were outlined by Department of Environment Malaysia (DOE) based on Environment Quality Act 1974. (author)

  19. A review of reagents for fluorescence microscopy of cellular compartments and structures, part I: BacMam labeling and reagents for vesicular structures.

    Science.gov (United States)

    Dolman, Nick J; Kilgore, Jason A; Davidson, Michael W

    2013-07-01

    Fluorescent labeling of vesicular structures in cultured cells, particularly for live cells, can be challenging for a number of reasons. The first challenge is to identify a reagent that will be specific enough where some structures have a number of potential reagents and others very few options. The emergence of BacMam constructs has allowed more easy-to-use choices. Presented here is a discussion of BacMam constructs as well as a review of commercially-available reagents for labeling vesicular structures in cells, including endosomes, peroxisomes, lysosomes, and autophagosomes, complete with a featured reagent for each structure, recommended protocol, troubleshooting guide, and example image. © 2013 by John Wiley & Sons, Inc.

  20. A Snippet of Grignard Reagent's Histroy There are very few reagents ...

    Indian Academy of Sciences (India)

    IAS Admin

    with bromine, (eq.1). But he failed to notice the formation of phenylmagnesium bromide, because he was using excess bromine which destroyed it. Hence, he could isolate only bromobenzene,. (eq.2). Had he used only one molar equivalent of bromine, perhaps the organomagnesium reagent would bear his name today.

  1. Physically absorbable reagents-collectors in elementary flotation

    Energy Technology Data Exchange (ETDEWEB)

    S.A. Kondrat' ev; I.G. Bochkarev [Russian Academy of Sciences, Novosibirsk (Russian Federation). Institute of Mining

    2007-09-15

    Based on the reviewed researches held at the Institute of Mining, Siberian Branch, Russian Academy of Sciences, the effect of physically absorbable reagents-collectors on formation of a flotation complex and its stability in turbulent pulp flows in flotation machines of basic types is considered. The basic requirements for physically absorbable reagents-collectors at different flotation stages are established.

  2. STUDY ON OIL WASTEWATER TREATMENT WITH POLYMERIC REAGENTS

    Directory of Open Access Journals (Sweden)

    RODICA BUCUROIU

    2016-04-01

    Full Text Available Used the polymeric reagents in oil wastewater treatment is an effective method of eliminate hydrocarbons. The present study aims to finding reagents that lead to lowering of extractible (EXT, suspended solids (SS and chemical oxygen demand (COD of industrial wastewater from washing cars in loading ramps petroleum products. For this purpose five reagents were tested, namely: polyamines, cationic polyacrylamides, polydiallydimethyl ammonium chloride (PolyDADMAC, melamine formaldehyde polymer resin and polydicyandiamide polymer resin. Obtaining removal degrees over 80 % justifies using this method in the industrial practice.

  3. 21 CFR 866.3550 - Salmonella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3550 Salmonella... isolates derived from clinical specimens. Additionally, some of these reagents consist of antisera... clinical specimens or cultured isolates derived from clinical specimens. The identification aids in the...

  4. Uncertainty evaluation in normalization of isotope delta measurement results against international reference materials.

    Science.gov (United States)

    Meija, Juris; Chartrand, Michelle M G

    2018-01-01

    Isotope delta measurements are normalized against international reference standards. Although multi-point normalization is becoming a standard practice, the existing uncertainty evaluation practices are either undocumented or are incomplete. For multi-point normalization, we present errors-in-variables regression models for explicit accounting of the measurement uncertainty of the international standards along with the uncertainty that is attributed to their assigned values. This manuscript presents framework to account for the uncertainty that arises due to a small number of replicate measurements and discusses multi-laboratory data reduction while accounting for inevitable correlations between the laboratories due to the use of identical reference materials for calibration. Both frequentist and Bayesian methods of uncertainty analysis are discussed.

  5. 21 CFR 866.3355 - Listeria spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3355 Listeria spp... from clinical specimens. Additionally, some of these reagents consist of Listeria spp. antisera... clinical specimens. The identification aids in the diagnosis of listeriosis, a disease caused by bacteria...

  6. IN-PLACE REGENERATION OF GAC USING FENTON'S REAGENTS

    Science.gov (United States)

    This paper evaluates the feasibility of using Fenton’s reagents for in-place recovery of spent granular activated carbon (GAC). Fenton’s reagents are cycled through spent GAC to degrade sorbed chlorinated hydrocarbons with little loss of carbon capacity. Seven chlorinated compou...

  7. Establishing International Blood Pressure References Among Nonoverweight Children and Adolescents Aged 6 to 17 Years.

    Science.gov (United States)

    Xi, Bo; Zong, Xin'nan; Kelishadi, Roya; Hong, Young Mi; Khadilkar, Anuradha; Steffen, Lyn M; Nawarycz, Tadeusz; Krzywińska-Wiewiorowska, Małgorzata; Aounallah-Skhiri, Hajer; Bovet, Pascal; Chiolero, Arnaud; Pan, Haiyan; Litwin, Mieczysław; Poh, Bee Koon; Sung, Rita Y T; So, Hung-Kwan; Schwandt, Peter; Haas, Gerda-Maria; Neuhauser, Hannelore K; Marinov, Lachezar; Galcheva, Sonya V; Motlagh, Mohammad Esmaeil; Kim, Hae Soon; Khadilkar, Vaman; Krzyżaniak, Alicja; Romdhane, Habiba Ben; Heshmat, Ramin; Chiplonkar, Shashi; Stawińska-Witoszyńska, Barbara; El Ati, Jalila; Qorbani, Mostafa; Kajale, Neha; Traissac, Pierre; Ostrowska-Nawarycz, Lidia; Ardalan, Gelayol; Parthasarathy, Lavanya; Zhao, Min; Zhang, Tao

    2016-01-26

    Several distributions of country-specific blood pressure (BP) percentiles by sex, age, and height for children and adolescents have been established worldwide. However, there are no globally unified BP references for defining elevated BP in children and adolescents, which limits international comparisons of the prevalence of pediatric elevated BP. We aimed to establish international BP references for children and adolescents by using 7 nationally representative data sets (China, India, Iran, Korea, Poland, Tunisia, and the United States). Data on BP for 52 636 nonoverweight children and adolescents aged 6 to 19 years were obtained from 7 large nationally representative cross-sectional surveys in China, India, Iran, Korea, Poland, Tunisia, and the United States. BP values were obtained with certified mercury sphygmomanometers in all 7 countries by using standard procedures for BP measurement. Smoothed BP percentiles (50th, 90th, 95th, and 99th) by age and height were estimated by using the Generalized Additive Model for Location Scale and Shape model. BP values were similar between males and females until the age of 13 years and were higher in males than females thereafter. In comparison with the BP levels of the 90th and 95th percentiles of the US Fourth Report at median height, systolic BP of the corresponding percentiles of these international references was lower, whereas diastolic BP was similar. These international BP references will be a useful tool for international comparison of the prevalence of elevated BP in children and adolescents and may help to identify hypertensive youths in diverse populations. © 2015 American Heart Association, Inc.

  8. Storage Conditions of Conjugated Reagents Can Impact Results of Immunogenicity Assays

    Directory of Open Access Journals (Sweden)

    Robert J. Kubiak

    2016-01-01

    Full Text Available Consistent performance of anti-drug antibody (ADA assays through all stages of clinical development is critical for the assessment of immunogenicity and interpretation of PK, PD, safety, and efficacy. The electrochemiluminescent assays commonly employed for ADA measurement use drug conjugated with ruthenium and biotin to bind ADA in samples. Here we report an association between high nonspecific ADA responses in certain drug-naïve individuals and the storage buffer of the conjugated reagents used in a monoclonal antibody ADA assay. Ruthenylated reagents stored in phosphate-buffered saline (PBS buffer had increased levels of aggregate and produced variable and high baseline responses in some subjects. Reagents stored in a histidine-sucrose buffer (HSB had lower aggregate levels and produced low sample responses. In contrast to PBS, conjugated reagents formulated in HSB remained low in aggregate content and in sample response variability after 5 freeze/thaw cycles. A reagent monitoring control (RMC serum was prepared for the real-time evaluation of conjugated reagent quality. Using appropriate buffers for storage of conjugated reagents together with RMCs capable of monitoring of reagent aggregation status can help ensure consistent, long-term performance of ADA methods.

  9. Transformations of diaziridines and their fused analogues induced by electrophilic reagents

    International Nuclear Information System (INIS)

    Makhova, Nina N; Shevtsov, Alexander V; Petukhova, Vera Yu

    2011-01-01

    The review deals with transformations of mono- and bicyclic diaziridine derivatives with different types of substitution induced by electrophilic reagents (protic acids, Lewis acids, alkylating and acylating agents, carbonyl compounds, heterocumulenes, activated alkenes and alkynes and transition metal salts). The characteristic features of the reactions are considered as functions of the structures of the starting diaziridines and the nature of the reaction medium (organic solvents, ionic liquids). Prospects of the use of diaziridine derivatives as readily available precursors for the synthesis of various nitrogen-containing heterocyclic systems based on the diaziridine ring expansion reactions are considered. The bibliography includes 136 references.

  10. Use of internal references for assessing CT density measurements of the pelvis as replacement for use of an external phantom.

    Science.gov (United States)

    Boomsma, Martijn F; Slouwerhof, Inge; van Dalen, Jorn A; Edens, Mireille A; Mueller, Dirk; Milles, Julien; Maas, Mario

    2015-11-01

    The purpose of this research is to study the use of an internal reference standard for fat- and muscle as a replacement for an external reference standard with a phantom. By using a phantomless internal reference standard, Hounsfield unit (HU) measurements of various tissues can potentially be assessed in patients with a CT scan of the pelvis without an added phantom at time of CT acquisition. This paves the way for development of a tool for quantification of the change in tissue density in one patient over time and between patients. This could make every CT scan made without contrast available for research purposes. Fifty patients with unilateral metal-on-metal total hip replacements, scanned together with a calibration reference phantom used in bone mineral density measurements, were included in this study. On computed tomography scans of the pelvis without the use of intravenous iodine contrast, reference values for fat and muscle were measured in the phantom as well as within the patient's body. The conformity between the references was examined with the intra-class correlation coefficient. The mean HU (± SD) of reference values for fat for the internal- and phantom references were -91.5 (±7.0) and -90.9 (±7.8), respectively. For muscle, the mean HU (± SD) for the internal- and phantom references were 59.2 (±6.2) and 60.0 (±7.2), respectively. The intra-class correlation coefficients for fat and muscle were 0.90 and 0.84 respectively and show excellent agreement between the phantom and internal references. Internal references can be used with similar accuracy as references from an external phantom. There is no need to use an external phantom to asses CT density measurements of body tissue.

  11. Use of internal references for assessing CT density measurements of the pelvis as replacement for use of an external phantom

    Energy Technology Data Exchange (ETDEWEB)

    Boomsma, Martijn F.; Slouwerhof, Inge; Dalen, Jorn A. van [Isala Hospital, Department of Radiology, Zwolle (Netherlands); Edens, Mireille A. [Isala Hospital, Department of Innovation and Science, Zwolle (Netherlands); Mueller, Dirk [Philips Healthcare systems, Hamburg (Germany); Milles, Julien [Philips Healthcare Benelux, Eindhoven (Netherlands); Maas, Mario [AMC, Department of Radiology, Amsterdam (Netherlands)

    2015-11-15

    The purpose of this research is to study the use of an internal reference standard for fat- and muscle as a replacement for an external reference standard with a phantom. By using a phantomless internal reference standard, Hounsfield unit (HU) measurements of various tissues can potentially be assessed in patients with a CT scan of the pelvis without an added phantom at time of CT acquisition. This paves the way for development of a tool for quantification of the change in tissue density in one patient over time and between patients. This could make every CT scan made without contrast available for research purposes. Fifty patients with unilateral metal-on-metal total hip replacements, scanned together with a calibration reference phantom used in bone mineral density measurements, were included in this study. On computed tomography scans of the pelvis without the use of intravenous iodine contrast, reference values for fat and muscle were measured in the phantom as well as within the patient's body. The conformity between the references was examined with the intra-class correlation coefficient. The mean HU (± SD) of reference values for fat for the internal- and phantom references were -91.5 (±7.0) and -90.9 (±7.8), respectively. For muscle, the mean HU (± SD) for the internal- and phantom references were 59.2 (±6.2) and 60.0 (±7.2), respectively. The intra-class correlation coefficients for fat and muscle were 0.90 and 0.84 respectively and show excellent agreement between the phantom and internal references. Internal references can be used with similar accuracy as references from an external phantom. There is no need to use an external phantom to asses CT density measurements of body tissue. (orig.)

  12. Systematic trends in photonic reagent induced reactions in a homologous chemical family.

    Science.gov (United States)

    Tibbetts, Katharine Moore; Xing, Xi; Rabitz, Herschel

    2013-08-29

    The growing use of ultrafast laser pulses to induce chemical reactions prompts consideration of these pulses as "photonic reagents" in analogy to chemical reagents. This work explores the prospect that photonic reagents may affect systematic trends in dissociative ionization reactions of a homologous family of halomethanes, much as systematic outcomes are often observed for reactions between homologous families of chemical reagents and chemical substrates. The experiments in this work with photonic reagents of varying pulse energy and linear spectral chirp reveal systematic correlations between observable ion yields and the following set of natural variables describing the substrate molecules: the ionization energy of the parent molecule, the appearance energy of each fragment ion, and the relative strength of carbon-halogen bonds in molecules containing two different halogens. The results suggest that reactions induced by photonic reagents exhibit systematic behavior analogous to that observed in reactions driven by chemical reagents, which provides a basis to consider empirical "rules" for predicting the outcomes of photonic reagent induced reactions.

  13. The Generalized Internal/External Frame of Reference Model: An Extension to Dimensional Comparison Theory

    Science.gov (United States)

    Möller, Jens; Müller-Kalthoff, Hanno; Helm, Friederike; Nagy, Nicole; Marsh, Herb W.

    2016-01-01

    The dimensional comparison theory (DCT) focuses on the effects of internal, dimensional comparisons (e.g., "How good am I in math compared to English?") on academic self-concepts with widespread consequences for students' self-evaluation, motivation, and behavioral choices. DCT is based on the internal/external frame of reference model…

  14. International Celestial Reference Frame (ICRF): mantenimiento y extensión

    Science.gov (United States)

    Ma, C.; Arias, E. F.; Eubanks, T.; Fey, A. L.; Gontier, A.-M.; Jacobs, C. S.; Sovers, O. J.; Archinal, B. A.; Charlot, P.

    A partir de enero de 1998 el sistema de referencia celeste convencional está representado por el International Celestial Reference System (ICRS) y materializado a través de las coordenadas VLBI del conjunto de radiofuentes extragalácticas que conforman el International Celestial Reference Frame (ICRF). La primera realización del ICRF, fue elaborada en 1995 por un grupo de expertos designado por la IAU, la que encomendó al International Earth Rotation Service el mantenimiento del ICRS, del ICRF y del vínculo con marcos de referencia en otras frecuencias. Una primera extensión del ICRF se realizó entre abril y junio de 1999, con el objetivo primario de proveer posiciones de radiofuentes extragalácticas observadas a partir de julio de 1995 y de mejorar las posiciones de las fuentes ``candidatas" con la inclusión de observaciones adicionales. Objetivos secundarios fueron monitorear a las radiofuentes para verificar que siguen siendo adecuadas para realizar al ICRF y mejorar las técnicas de análisis de datos. Como resultado del nuevo análisis se obtuvo una solución a partir de la cual se construyó la primera extensión del ICRF, denominada ICRF - Ext.1. Ella representa al ICRS, sus fuentes de definición se mantienen con las mismas posiciones y errores que en la primera realización del ICRF; las demás radiofuentes tienen coordenadas mejor determinadas que en ICRF; el marco de referencia se densificó con el agregado de 59 nuevas radiofuentes.

  15. 21 CFR 864.8950 - Russell viper venom reagent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Russell viper venom reagent. 864.8950 Section 864.8950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8950 Russell viper venom...

  16. 125I-labeled crosslinking reagent that is hydrophilic, photoactivatable, and cleavable through an azo linkage

    International Nuclear Information System (INIS)

    Denny, J.B.; Blobel, G.

    1984-01-01

    A radioactive crosslinking reagent, N-[4-(p-azido-m-[ 125 I]iodophenylazo)benzoyl]-3-aminopropyl-N'-oxysulfosuccinimide ester, has been synthesized. The reagent is photoactivatable, water-soluble, cleavable through an azo linkage, and labeled with 125 I at the carrier-free specific activity of 2000 Ci/mmol. Any protein derivatized with the reagent is thus converted into an 125 I-labeled photoaffinity probe. Crosslinks are formed following photolysis with 366-nm light, and cleavage by sodium dithionite results in the donation of radioactivity to the distal partner in crosslinked complexes. The newly labeled proteins are then analyzed by gel electrophoresis and autoradiography. The compound was prepared by iodination of N-[4-(p-aminophenylazo)benzoyl]-3-aminopropionic acid using carrier-free Na 125 I and chloramine-T, followed by azide formation and conversion to the water-soluble sulfosuccinimide ester. As a model system, protein A-Sepharose was derivatized with the reagent under subdued light. Each derivatized protein A molecule contained only one crosslinker. The derivatized protein A-Sepharose was then photolyzed in the presence of human serum and subsequently treated with sodium dithionite. Analysis of the serum by gel electrophoresis revealed that 1.1% of the radioactive label originally present on the protein A-Sepharose was transferred to the heavy chain of IgG, which was the most intensely labeled protein in the gel. The next most intensely labeled protein was IgG light chain, which incorporated radioactivity that was lower by a factor of 3.6 than that of the heavy chain. 36 references, 3 figures

  17. International collaborative study for the calibration of proposed International Standards for thromboplastin, rabbit, plain and for thromboplastin, recombinant, human, plain

    DEFF Research Database (Denmark)

    van den Besselaar, A M H P; Chantarangkul, V; Angeloni, F

    2018-01-01

    BACKGROUND: The availability of International Standards for thromboplastin is essential for the calibration of routine reagents and hence the calculation of the International Normalized Ratio (INR). Stocks of the current 4(th) International Standards are running low. Candidate replacement materia......) international standard (rTF/09). The candidate materials have been accepted by WHO as the 5(th) International Standards for thromboplastin, rabbit plain, and thromboplastin, recombinant, human, plain. This article is protected by copyright. All rights reserved.......BACKGROUND: The availability of International Standards for thromboplastin is essential for the calibration of routine reagents and hence the calculation of the International Normalized Ratio (INR). Stocks of the current 4(th) International Standards are running low. Candidate replacement materials...... have been prepared. This report describes the calibration of the proposed 5(th) International Standards for thromboplastin, rabbit, plain (coded RBT/16) and for thromboplastin, recombinant, human, plain (coded rTF/16). METHODS: An international collaborative study was carried out for the assignment...

  18. Diagnóstico das meningites através de fitas reagentes Diagnosis of meningitis with reagent strips

    Directory of Open Access Journals (Sweden)

    Roberta M.C. Romanelli

    2001-06-01

    Full Text Available OBJETIVO: determinar a utilidade de fitas reagentes para a avaliação liquórica de pleocitose, glicorraquia e proteinorraquia no diagnóstico precoce e rápido de meningites em crianças. MÉTODOS: Foram incluídas no estudo amostras de líquor provenientes de 164 crianças admitidas no ambulatório de doenças infecto-contagiosas do Centro Geral de Pediatria (CGP-FHEMIG, com suspeita clínica de meningite, no período diurno de Maio/97 à Maio/99. A faixa etária dos pacientes variou de um mês a 12 anos (mediana de 12 meses, sendo obtidos resultados da citobioquímica liquórica (celularidade, glicorraquia e proteinorraquia de 154 desses pacientes. Esses achados foram comparados com reações do líquor em fitas reagentes. RESULTADOS: Através da citobioquímica líquórica foram identificados 43 casos de provável meningite bacteriana, 19 provavelmente viróticas e 83 amostras sem alterações. Pelas fitas reagentes, detectaram-se 41 casos de provável meningite bacteriana, dois casos de infecção meníngea provavelmente virótica, e em 71 exames não se verificaram alterações. Comparando os resultados obtidos por meio das fitas reagentes com a citobioquímica convencional, observou-se sensibilidade, especificidade, valores preditivos positivo e negativo e acurácia (90,7; 98,1; 95,1; 96,4; 96,1%, respectivamente. Ademais, a análise estatística pelo teste de Mc Nemar não evidenciou discordância significativa no diagnóstico de meningite bacteriana obtido através de ambos os métodos (p=0,68 e, pela estatística Kappa, verificou-se elevado grau de concordância entre os testes (pOBJECTIVE: to determine the usefulness of reagent strips in the evaluation of pleocytosis, cerebrospinal fluid glucose and protein levels for early and rapid diagnosis of meningitis in children. METHODS: We included cerebrospinal fluid samples of 164 children admitted to the outpatient clinic of Communicable Diseases of the General Pediatric Center (Funda

  19. Evaluation of novel derivatisation reagents for the analysis of oxysterols

    Energy Technology Data Exchange (ETDEWEB)

    Crick, Peter J., E-mail: p.j.crick@swansea.ac.uk [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Aponte, Jennifer; Bentley, T. William [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Matthews, Ian [College of Engineering, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Wang, Yuqin [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Griffiths, William J., E-mail: w.j.griffiths@swansea.ac.uk [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom)

    2014-04-11

    Graphical abstract: - Highlights: • New derivatisation reagents for LC–MS analysis of oxysterols. • New reagents based on Girard P give high ion-currents and informative LC–MS{sup n} spectra. • Permanent charge is vital for efficient MS{sup n} fragmentation. • New reagents offer greater scope for incorporation of isotope labels. - Abstract: Oxysterols are oxidised forms of cholesterol that are intermediates in the synthesis of bile acids and steroid hormones. They are also ligands to nuclear and G protein-coupled receptors. Analysis of oxysterols in biological systems is challenging due to their low abundance coupled with their lack of a strong chromophore and poor ionisation characteristics in mass spectrometry (MS). We have previously used enzyme-assisted derivatisation for sterol analysis (EADSA) to identify and quantitate oxysterols in biological samples. This technique relies on tagging sterols with the Girard P reagent to introduce a charged quaternary ammonium group. Here, we have compared several modified Girard-like reagents and show that the permanent charge is vital for efficient MS{sup n} fragmentation. However, we find that the reagent can be extended to include sites for potential stable isotope labels without a loss of performance.

  20. Validity of HydraTrend reagent strips for the assessment of hydration status.

    Science.gov (United States)

    Abbey, Bryce M; Heelan, Kate A; Brown, Gregory A; Bartee, Rodrick T

    2014-09-01

    Hydration is used by athletic governing organizations for weight class eligibility. The measurement of urine specific gravity (USG) as a measure of hydration by reagent strips is a controversial issue. The purpose of this study was to determine the validity of HydraTrend reagent strips that facilitate the correction of USG for alkaline urine samples against refractometry for the assessment of USG. Fifty-one participants (33 males, age = 22.3 ± 1.3 years; 18 females, age = 22.4 ± 1.2 years) provided 84 urine samples. The samples were tested for USG using refractometry and reagent strips and for pH using reagent strips and a digital pH meter. Strong correlation coefficients were found between refractometry and reagent strips for USG (rs(82) = 0.812, p refractometry with USG >1.020, pass reagent strips with USG ≤1.020) occurred 39% (33/84) of the time and false negative results for National Federation of State High School Association (NFHS) requirements (fail refractometry with USG >1.025, pass reagent strips with USG ≤1.025) occurred 14% (12/84) of the time. There were no false positives (pass refractometry and fail reagent strips) for NCAA or NFHS requirements. These data show that refractometry and reagent strips have strong positive correlations. However, the risk of a false negative result leading to incorrect certification of euhydration status outweighs the benefits of the HydraTrend reagent strips for the measurement of USG.

  1. Data on final calcium concentration in native gel reagents determined accurately through inductively coupled plasma measurements

    Directory of Open Access Journals (Sweden)

    Jeffrey Viviano

    2016-03-01

    Full Text Available In this article we present data on the concentration of calcium as determined by Inductively Coupled Plasma (ICP measurements. Calcium was estimated in the reagents used for native gel electrophoresis of Neuronal Calcium Sensor (NCS proteins. NCS proteins exhibit calcium-dependent mobility shift in native gels. The sensitivity of this shift to calcium necessitated a precise determination of calcium concentrations in all reagents used. We determined the calcium concentrations in different components used along with the samples in the native gel experiments. These were: 20 mM Tris pH 7.5, loading dye and running buffer, with distilled water as reference. Calcium determinations were through ICP measurements. It was found that the running buffer contained calcium (244 nM over the blank. Keywords: Neuronal calcium sensor proteins, Electrophoresis, Mobility shift, Calcium, Magnesium

  2. Reagent and process for detaching furfural in petroleum products

    Energy Technology Data Exchange (ETDEWEB)

    Orelup, R.B.

    1987-07-14

    A two-component liquid reagent and process is provided for detecting the presence of furfural in petroleum products. The reagent comprises two components which are stored separately from each other and are combined prior to admixture with the petroleum product. The process comprises combining the two separate components of the liquid reagent with each other prior to use, admixing the combined components with a petroleum product containing furfural, shaking the resultant mixture, allowing the mixture to separate and observing a red color characteristic of furfural in the lower layer. Alternately, the process may be carried out by combining the second component of the two-component liquid reagent with the petroleum product, followed by admixture with the first component to obtain two separate layers in which the red color characteristic of furfural is observed in the lower layer.

  3. The reaction of organocerium reagents with easily enolizable ketones

    International Nuclear Information System (INIS)

    Imamoto, Tsuneo; Kusumoto, Tetsuo; Sugiura, Yasushi; Suzuki, Nobuyo; Takiyama, Nobuyuki

    1985-01-01

    Organocerium (III) reagents were conveniently generated by the reaction of organolithium compounds with anhydrous cerium (III) chloride. The reagents are less basic than organolithiums and Grignard reagents, and they react readily at -78 deg C with easily enolizable ketones such as 2-tetralone to afford addition products in high yields. Cerium (III) enolates were also generated from lithium enolates and cerium (III) chloride. The cerium (III) enolates undergo aldol addition with ketones or sterically crowded aldehyde to give the corresponding β-hydroxy ketones in good to high yields. (author)

  4. Simultaneous determination of glucose, triglycerides, urea, cholesterol, albumin and total protein in human plasma by Fourier transform infrared spectroscopy: direct clinical biochemistry without reagents.

    Science.gov (United States)

    Jessen, Torben E; Höskuldsson, Agnar T; Bjerrum, Poul J; Verder, Henrik; Sørensen, Lars; Bratholm, Palle S; Christensen, Bo; Jensen, Lene S; Jensen, Maria A B

    2014-09-01

    Direct measurement of chemical constituents in complex biologic matrices without the use of analyte specific reagents could be a step forward toward the simplification of clinical biochemistry. Problems related to reagents such as production errors, improper handling, and lot-to-lot variations would be eliminated as well as errors occurring during assay execution. We describe and validate a reagent free method for direct measurement of six analytes in human plasma based on Fourier-transform infrared spectroscopy (FTIR). Blood plasma is analyzed without any sample preparation. FTIR spectrum of the raw plasma is recorded in a sampling cuvette specially designed for measurement of aqueous solutions. For each analyte, a mathematical calibration process is performed by a stepwise selection of wavelengths giving the optimal least-squares correlation between the measured FTIR signal and the analyte concentration measured by conventional clinical reference methods. The developed calibration algorithms are subsequently evaluated for their capability to predict the concentration of the six analytes in blinded patient samples. The correlation between the six FTIR methods and corresponding reference methods were 0.87albumin and total protein in human plasma. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. Establishing International Blood Pressure References Among Non-Overweight Children and Adolescents Aged 6–17 Years

    Science.gov (United States)

    Xi, Bo; Zong, Xin’nan; Kelishadi, Roya; Hong, Young Mi; Khadilkar, Anuradha; Steffen, Lyn M.; Nawarycz, Tadeusz; Krzywińska-Wiewiorowska, Małgorzata; Aounallah-Skhiri, Hajer; Bovet, Pascal; Chiolero, Arnaud; Pan, Haiyan; Litwin, Mieczysław; Poh, Bee Koon; Sung, Rita Y.T.; So, Hung-Kwan; Schwandt, Peter; Haas, Gerda-Maria; Neuhauser, Hannelore K.; Marinov, Lachezar; Galcheva, Sonya V; Motlagh, Mohammad Esmaeil; Kim, Hae Soon; Khadilkar, Vaman; Krzyżaniak, Alicja; Ben Romdhane, Habiba; Heshmat, Ramin; Chiplonkar, Shashi; Stawińska-Witoszyńska, Barbara; Ati, Jalila El; Qorbani, Mostafa; Kajale, Neha; Traissac, Pierre; Ostrowska-Nawarycz, Lidia; Ardalan, Gelayol; Parthasarathy, Lavanya; Zhao, Min; Zhang, Tao

    2015-01-01

    Background Several distributions of country-specific blood pressure (BP) percentiles by sex, age and height for children and adolescents have been established worldwide. However, there are no globally unified BP references for defining elevated BP in children and adolescents, which limit international comparisons of prevalence of pediatric elevated BP. We aimed to establish international BP references for children and adolescents using seven nationally representative data (China, India, Iran, Korea, Poland, Tunisia and USA). Methods and Results Data on BP for 52,636 non-overweight children and adolescents aged 6–19 years were obtained from seven large nationally representative cross-sectional surveys in China, India, Iran, Korea, Poland, Tunisia, and USA. BP values were obtained with certified mercury sphygmomanometers in all seven countries, using standard procedures for BP measurement. Smoothed BP percentiles (50th, 90th, 95th and 99th) by age and height were estimated using the Generalized Additive Model for Location Scale and Shape (GAMLSS) model. BP values were similar between males and females until the age of 13 years and were higher in males than females thereafter. Compared to BP level of the 90th and 95th percentiles of the U.S. Fourth Report at median height, systolic BP of the corresponding percentiles of these international references was lower while diastolic BP was similar. Conclusions These international BP references will be a useful tool for international comparison of the prevalence of elevated BP in children and adolescents and may help identify hypertensive youths in diverse populations. PMID:26671979

  6. Reagent for treating clay drilling muds

    Energy Technology Data Exchange (ETDEWEB)

    Tkachenko, P V; Leshchinskiy, P A; Shnaper, B I; Zinchuk, I F; Zlobin, V P

    1982-01-01

    A reagent is proposed for treating clay drilling muds. It contains lignite, caustic soda and modifying agent. It is distinguished by the fact that in order to reduce the cost of the reagent with simultaneous decrease in the viscosity and static shear stress of the drilling mud, it additionally contains iron sulfate, and the modifying agent contained is wastes of carbonic acid production with the following ratio of components (parts by weight): lignite 10.0-15.0, caustic soda 2.0-3.0, wastes of carbonic acid production 0.5-0.75; iron sulfate 1.0-2.0.

  7. A review of reagents for fluorescence microscopy of cellular compartments and structures, Part III: reagents for actin, tubulin, cellular membranes, and whole cell and cytoplasm.

    Science.gov (United States)

    Kilgore, Jason A; Dolman, Nick J; Davidson, Michael W

    2014-01-02

    Non-antibody commercial fluorescent reagents for imaging of cytoskeletal structures have been limited primarily to tubulin and actin, with the main factor in choice based mainly on whether cells are live or fixed and permeabilized. A wider range of options exist for cell membrane dyes, and the choice of reagent primarily depends on the preferred localization in the cell (i.e., all membranes or only the plasma membrane) and usage (i.e., whether the protocol involves fixation and permeabilization). For whole-cell or cytoplasmic imaging, the choice of reagent is determined mostly by the length of time that the cells need to be visualized (hours or days) and by fixation status. Presented here is a discussion on choosing commercially available reagents for these cellular structures, with an emphasis on use for microscopic imaging, with a featured reagent for each structure, a recommended protocol, troubleshooting guide, and example image. Copyright © 2014 John Wiley & Sons, Inc.

  8. Henry Hub and national balancing point prices: what will be the international gas price reference?

    International Nuclear Information System (INIS)

    Mazighi, A.E.H.

    2005-01-01

    One of the lessons in the history of international trade in commodities is the emergence - sooner or later - of an international price reference, most commonly known as an international marker price. In the area of oil, West Texas Intermediate (WTI) plays the role of a marker for sour crudes traded in the Atlantic basin. Brent oil fulfils this function for sweet crudes traded in Europe. Another important aspect in the area of global commodities is that the emergence of a marker price is not always necessarily related to the relative share of production of exports of the commodity, but primarily to the existence of an organized market for this commodity. Today, while international gas trade is intensifying, we still lack an international price reference for this commodity. This is due to the fact that the international trade of natural gas is still highly regionalized. It is also due to the fact that most gas markets are still regulated. Nevertheless, deregulation efforts have been implemented in both developed (the United States, the United Kingdom, continental Europe, Korea) and developing countries (Brazil, Chile) and have led to new market structures based on more competition in all segments of the gas chain, except transportation. In the meantime, price structures based on supply and demand principles are supposed to have emerged in the US and UK markets in the 1990s as a result of the implementation of deregulation measures. Today, the US gas market, which represents more than 660 billion cubic metres per year of consumption and the UK gas market, which is close to 100 bcm annually, are considered mature enough to make the principles of supply and demand operate inside these markets. In fact, the Henry Hub (HH) price, which is determined at a physical location in Louisiana, US, and the national balancing point (NBP) price, which is determined somewhere inside the national transmission system (NTS), without any precise location, are considered as potential

  9. Field-Portable Immunoassay Instruments and Reagents to Measure Chelators and Mobile Forms of Uranium

    International Nuclear Information System (INIS)

    Blake, Diane A.

    2003-01-01

    The goals for the 3-year project period are (1) to test and validate the present uranium sensor and develop protocols for its use at the NABIR Field Research Center; (2) to develop new reagents that will provide superior performance for the present hand-held immunosensor; and (3) to develop new antibodies that will permit this sensor to also measure other environmental contaminants (chromium, mercury, and/or DTPA). Sensor design modifications are underway via international collaborations. New reagents that will provide superior performance for the present hand-held immunosensor are being prepared and tested. New methods have been developed, to produce recombinant forms of metal-specific monoclonal antibodies for use with the sensor. Site-directed mutagenesis experiments are underway to determine the mechanisms of binding. Immunization experiments with sheep and rabbits to develop new recombinant forms of antibodies to metal-chelate complexes (chromium, mercury, and/or DTPA) have been initiated

  10. Customized Internal Reference Controls for Improved Assessment of Circulating MicroRNAs in Disease.

    Directory of Open Access Journals (Sweden)

    Kenny Schlosser

    Full Text Available Altered levels of circulating extracellular miRNA in plasma and serum have shown promise as non-invasive biomarkers of disease. However, unlike the assessment of cellular miRNA levels for which there are accepted housekeeping genes, analogous reference controls for normalization of circulating miRNA are lacking. Here, we provide an approach to identify and validate circulating miRNA reference controls on a de novo basis, and demonstrate the advantages of these customized internal controls in different disease settings. Importantly, these internal controls overcome key limitations of external spike-in controls.Using a global RT-qPCR screen of 1066 miRNAs in plasma from pulmonary hypertension patients (PAH and healthy subjects as a case example, we identified a large pool of initial candidate miRNAs that were systematically ranked according to their plasma level stability using a predefined algorithm. The performance of the top candidates was validated against multiple comparators, and in a second independent cohort of PAH and control subjects. The broader utility of this approach was demonstrated in a completely different disease setting with 372 miRNAs screened in plasma from septic shock patients and healthy controls.Normalization of data with specific internal reference controls significantly reduced the overall variation in circulating miRNA levels between subjects (relative to raw data, provided a more balanced distribution of up- and down-regulated miRNAs, replicated the results obtained by the benchmark geometric averaging of all detected miRNAs, and outperformed the commonly used external spike-in strategy.We demonstrate the feasibility of identifying circulating reference controls that can reduce extraneous technical variations, and improve the assessment of disease-related changes in plasma miRNA levels. This study provides a novel conceptual framework that addresses a critical and previously unmet need if circulating miRNAs are to

  11. Optimal lipofection reagent varies with the molecular modifications of the DNA.

    Science.gov (United States)

    Conrad, A H; Behlke, M A; Jaffredo, T; Conrad, G W

    1998-10-01

    Cationic lipid reagents differ in their cytofection efficacy with different cell types. No evidence has addressed whether the same lipid reagent is best for different DNAs in a single cell line. Immortalized avian embryonic cardiomyocytes cultured in vitro were tested with 15 cationic lipid reagents using (A) a beta-gal expression plasmid, (B) a fluorescein-tagged, phosphorothioate-modified ODN B, (C) a fluorescein-tagged, ethoxy-modified ODN C with the same nucleotide sequence as ODN B, and (D) a fluorescein-tagged, phosphorothioate-modified ODN D with a different nucleotide sequence from ODNs B and C. Cytofection was scored as percent of cells expressing beta-gal activity or showing diffuse cellular fluorescence. The best lipid reagents for the phosphorothioate-modified ODNs were ODN-specific and markedly different from the best lipid reagents for the expression plasmid or for the ethoxy-modified ODN. These results suggest that the best cationic lipid reagent for a particular cell type varies with the physical and chemical form of the DNA being transfected into the cells.

  12. Preface: International Reference Ionosphere - Progress in Ionospheric Modelling

    Science.gov (United States)

    Bilitza Dieter; Reinisch, Bodo

    2010-01-01

    The international reference ionosphere (lRI) is the internationally recommended empirical model for the specification of ionospheric parameters supported by the Committee on Space Research (COSPAR) and the International Union of Radio Science (URSI) and recognized by the International Standardization Organization (ISO). IRI is being continually improved by a team of international experts as new data become available and better models are being developed. This issue chronicles the latest phase of model updates as reported during two IRI-related meetings. The first was a special session during the Scientific Assembly of the Committee of Space Research (COSPAR) in Montreal, Canada in July 2008 and the second was an IRI Task Force Activity at the US Air Force Academy in Colorado Springs in May 2009. This work led to several improvements and additions of the model which will be included in the next version, IRI-201O. The issue is divided into three sections focusing on the improvements made in the topside ionosphere, the F-peak, and the lower ionosphere, respectively. This issue would not have been possible without the reviewing efforts of many individuals. Each paper was reviewed by two referees. We thankfully acknowledge the contribution to this issue made by the following reviewers: Jacob Adeniyi, David Altadill, Eduardo Araujo, Feza Arikan, Dieter Bilitza, Jilijana Cander, Bela Fejer, Tamara Gulyaeva, Manuel Hermindez-Pajares, Ivan Kutiev, John MacDougal, Leo McNamara, Bruno Nava, Olivier Obrou, Elijah Oyeyemi, Vadym Paznukhov, Bodo Reinisch, John Retterer, Phil Richards, Gary Sales, J.H. Sastri, Ludger Scherliess, Iwona Stanislavska, Stamir Stankov, Shin-Yi Su, Manlian Zhang, Y ongliang Zhang, and Irina Zakharenkova. We are grateful to Peggy Ann Shea for her final review and guidance as the editor-in-chief for special issues of Advances in Space Research. We thank the authors for their timely submission and their quick response to the reviewer comments and humbly

  13. Improving the efficiency of quantitative (1)H NMR: an innovative external standard-internal reference approach.

    Science.gov (United States)

    Huang, Yande; Su, Bao-Ning; Ye, Qingmei; Palaniswamy, Venkatapuram A; Bolgar, Mark S; Raglione, Thomas V

    2014-01-01

    The classical internal standard quantitative NMR (qNMR) method determines the purity of an analyte by the determination of a solution containing the analyte and a standard. Therefore, the standard must meet the requirements of chemical compatibility and lack of resonance interference with the analyte as well as a known purity. The identification of such a standard can be time consuming and must be repeated for each analyte. In contrast, the external standard qNMR method utilizes a standard with a known purity to calibrate the NMR instrument. The external standard and the analyte are measured separately, thereby eliminating the matter of chemical compatibility and resonance interference between the standard and the analyte. However, the instrumental factors, including the quality of NMR tubes, must be kept the same. Any deviations will compromise the accuracy of the results. An innovative qNMR method reported herein utilizes an internal reference substance along with an external standard to assume the role of the standard used in the traditional internal standard qNMR method. In this new method, the internal reference substance must only be chemically compatible and be free of resonance-interference with the analyte or external standard whereas the external standard must only be of a known purity. The exact purity or concentration of the internal reference substance is not required as long as the same quantity is added to the external standard and the analyte. The new method reduces the burden of searching for an appropriate standard for each analyte significantly. Therefore the efficiency of the qNMR purity assay increases while the precision of the internal standard method is retained. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. 21 CFR 866.3520 - Rubeola (measles) virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rubeola (measles) virus serological reagents. 866... Rubeola (measles) virus serological reagents. (a) Identification. Rubeola (measles) virus serological... to rubeola virus in serum. The identification aids in the diagnosis of measles and provides...

  15. Efficacy comparative of different laboratory test reagents for hepatitis C virus antibody

    Directory of Open Access Journals (Sweden)

    GUO Feibo

    2016-09-01

    Full Text Available Objective To investigate the effects of different laboratory test reagents for hepatitis C virus (HCV antibody through a comparative analysis. Methods A total of 207 samples which tested positive by four anti-HCV screening reagents commonly used in the laboratories in China (Kehua, Xinchuang, Wantai, and Abbott were included. HCV RNA nucleic acid amplification (NAT was performed, and if NAT results were negative, recombinant immunoblot assay (RIBA was performed for further confirmation. The test results of these four screening reagents were compared, and their S/CO values and true positive rates were analyzed. Results Of all the 205 samples testing positive by any one reagent, 191 (93.2% tested positive by the four reagents, and 14 (6.8% were tested inconsistently by the four reagents. The positive predictive values of Xinchuang, Kehua, Wantai, and Abbott reagents were 88.2% (180/204, 93.8% (180/192, 91.4% (180/197, and 90.0% (180/200, respectively. The S/CO thresholds with a positive predictive value of ≥95% for Xinchuang, Kehua, Wantai, and Abbott reagents were 9.0, 4.0, 5.0, and 7.0, respectively. Conclusion Xinchuang, Kehua, Wantai, and Abbott reagents have significantly different S/CO thresholds with a positive predictive value of ≥95%, which are significantly different from those in other domestic laboratories. Each laboratory should establish an applicable S/CO threshold with a positive predictive value of ≥95%, in order to reduce the sample size for confirmatory test.

  16. N-tritioacetoxyphthalimide: A new high specific activity tritioacetylating reagent

    International Nuclear Information System (INIS)

    Saljoughian, M.; Morimoto, Hiromi; Than, Chit

    1996-01-01

    The authors' aim was to develop a nonvolatile, stable, and facile tritioacetylating reagent and to demonstrate its use on simple peptides. Accordingly, the authors made the synthesis of high specific activity N-(tritioacetoxy) derivatives of succinimide, phthalimide, and naphthalimide a major focus. As the preferred approach, N-(tritioacetoxy)phthalimide was prepared by radical dehalogenation of N-(iodoacetoxy)phthalimide using high specific activity tributyltin tritide. This tritiated acetylation reagent was characterized by 3 H and 1 H NMR spectroscopy and by radio-HPLC. Efficacy of the reagent was investigated by tritioacetylation of several peptides at their N-terminal amino group. 26 refs., 1 fig

  17. [Research of regional medical consumables reagent logistics system in the modern hospital].

    Science.gov (United States)

    Wu, Jingjiong; Zhang, Yanwen; Luo, Xiaochen; Zhang, Qing; Zhu, Jianxin

    2013-09-01

    To explore the modern hospital and regional medical consumable reagents logistics system management. The characteristics of regional logistics, through cooperation between medical institutions within the region, and organize a wide range of special logistics activities, to make reasonable of the regional medical consumable reagents logistics. To set the regional management system, dynamic management systems, supply chain information management system, after-sales service system and assessment system. By the research of existing medical market and medical resources, to establish the regional medical supplies reagents directory and the initial data. The emphasis is centralized dispatch of medical supplies reagents, to introduce qualified logistics company for dispatching, to improve the modern hospital management efficiency, to costs down. Regional medical center and regional community health service centers constitute a regional logistics network, the introduction of medical consumable reagents logistics services, fully embodies integrity level, relevance, purpose, environmental adaptability of characteristics by the medical consumable reagents regional logistics distribution. Modern logistics distribution systems can increase the area of medical consumables reagent management efficiency and reduce costs.

  18. Treatment of laundrette wastewater using Starbon and Fenton's reagent.

    Science.gov (United States)

    Tony, Maha A; Parker, Helen L; Clark, James H

    2016-09-18

    The use of grey water for a variety of purposes is gaining increased popularity as a means of preserving scarce freshwater resources. In this work, catalytic oxidation over Fenton's reagent and adsorption techniques using Starbon (mesoporous material derived from polysaccharides) has been applied. These novel techniques are used as an alternative to already studied treatments of grey water such as filtration and/or biological processes. In this study, grey water, collected from a commercial laundrette, has been used. Treatment efficiency was determined by changes in the chemical oxygen demand (COD) of the grey water. Experiments using Fenton's reagent at optimum conditions of Fe(3+) = 40 mg L(-1); H2O2 = 400 mg L(-1) and pH 3 were very successful, resulting in a 95% COD removal after 15 min. Treatment with Starbon adsorption was also effective, reaching up to 81% COD removal at pH 3 within 1 h. The combined treatment with Fenton's reagent and Starbon resulted in a 93% COD removal at a significantly reduced concentration of Fenton's reagent compared to the treatment with solo Fenton's reagent. This lower chemical dose has the advantage of reducing costs and lowering sludge generation.

  19. A Catalyst-Free Amination of Functional Organolithium Reagents by Flow Chemistry.

    Science.gov (United States)

    Kim, Heejin; Yonekura, Yuya; Yoshida, Jun-Ichi

    2018-04-03

    Reported is the electrophilic amination of functional organolithium intermediates with well-designed aminating reagents under mild reaction conditions using flow microreactors. The aminating reagents were optimized to achieve efficient C-N bond formation without using any catalyst. The electrophilic amination reactions of functionalized aryllithiums were successfully conducted under mild reaction conditions, within 1 minute, by using flow microreactors. The aminating reagent was also prepared by the flow method. Based on stopped-flow NMR analysis, the reaction time for the preparation of the aminating reagent was quickly optimized without the necessity of work-up. Integrated one-flow synthesis consisting of the generation of an aryllithium, the preparation of an aminating reagent, and their combined reaction was successfully achieved to give the desired amine within 5 minutes of total reaction time. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Lipid-based Transfection Reagents Exhibit Cryo-induced Increase in Transfection Efficiency

    Directory of Open Access Journals (Sweden)

    Helena Sork

    2016-01-01

    Full Text Available The advantages of lipid-based transfection reagents have permitted their widespread use in molecular biology and gene therapy. This study outlines the effect of cryo-manipulation of a cationic lipid-based formulation, Lipofectamine 2000, which, after being frozen and thawed, showed orders of magnitude higher plasmid delivery efficiency throughout eight different cell lines, without compromising cell viability. Increased transfection efficiency with the freeze-thawed reagent was also seen with 2'-O-methyl phosphorothioate oligonucleotide delivery and in a splice-correction assay. Most importantly, a log-scale improvement in gene delivery using the freeze-thawed reagent was seen in vivo. Using three different methods, we detected considerable differences in the polydispersity of the different nucleic acid complexes as well as observed a clear difference in their surface spreading and sedimentation, with the freeze-thawed ones displaying substantially higher rate of dispersion and deposition on the glass surface. This hitherto overlooked elevated potency of the freeze-thawed reagent facilitates the targeting of hard-to-transfect cells, accomplishes higher transfection rates, and decreases the overall amount of reagent needed for delivery. Additionally, as we also saw a slight increase in plasmid delivery using other freeze-thawed transfection reagents, we postulate that freeze-thawing might prove to be useful for an even wider variety of transfection reagents.

  1. Hydrogen sulfide deactivates common nitrobenzofurazan-based fluorescent thiol labeling reagents.

    Science.gov (United States)

    Montoya, Leticia A; Pluth, Michael D

    2014-06-17

    Sulfhydryl-containing compounds, including thiols and hydrogen sulfide (H2S), play important but differential roles in biological structure and function. One major challenge in separating the biological roles of thiols and H2S is developing tools to effectively separate the reactivity of these sulfhydryl-containing compounds. To address this challenge, we report the differential responses of common electrophilic fluorescent thiol labeling reagents, including nitrobenzofurazan-based scaffolds, maleimides, alkylating agents, and electrophilic aldehydes, toward cysteine and H2S. Although H2S reacted with all of the investigated scaffolds, the photophysical response to each scaffold was significantly different. Maleimide-based, alkylating, and aldehydic thiol labeling reagents provided a diminished fluorescence response when treated with H2S. By contrast, nitrobenzofurazan-based labeling reagents were deactivated by H2S addition. Furthermore, the addition of H2S to thiol-activated nitrobenzofurazan-based reagents reduced the fluorescence signal, thus establishing the incompatibility of nitrobenzofurazan-based thiol labeling reagents in the presence of H2S. Taken together, these studies highlight the differential reactivity of thiols and H2S toward common thiol-labeling reagents and suggest that sufficient care must be taken when labeling or measuring thiols in cellular environments that produce H2S due to the potential for both false-positive and eroded responses.

  2. The International Geomagnetic Reference Field (IGRF) generation 12: BGS candidates and final models

    OpenAIRE

    Beggan, Ciaran D.; Hamilton, Brian; Taylor, Victoria; Macmillan, Susan; Thomson, Alan

    2015-01-01

    The International Geomagnetic Reference Field (IGRF) model is a reference main field magnetic model updated on a quinquennial basis. The latest revision (generation 12) was released in January 2015. The IGRF-12 consists of a definitive model (DGRF2010) of the main field for 2010.0, a model for the field at 2015.0 (IGRF2015) and a prediction of secular variation (IGRF-12 SV) for the forthcoming five years until 2020.0. The remaining coefficients of IGRF-12 are unchanged from IGRF-11. Nin...

  3. International linear collider reference design report

    Energy Technology Data Exchange (ETDEWEB)

    Aarons, G.

    2007-06-22

    The International Linear Collider will give physicists a new cosmic doorway to explore energy regimes beyond the reach of today's accelerators. A proposed electron-positron collider, the ILC will complement the Large Hadron Collider, a proton-proton collider at the European Center for Nuclear Research (CERN) in Geneva, Switzerland, together unlocking some of the deepest mysteries in the universe. With LHC discoveries pointing the way, the ILC -- a true precision machine -- will provide the missing pieces of the puzzle. Consisting of two linear accelerators that face each other, the ILC will hurl some 10 billion electrons and their anti-particles, positrons, toward each other at nearly the speed of light. Superconducting accelerator cavities operating at temperatures near absolute zero give the particles more and more energy until they smash in a blazing crossfire at the centre of the machine. Stretching approximately 35 kilometres in length, the beams collide 14,000 times every second at extremely high energies -- 500 billion-electron-volts (GeV). Each spectacular collision creates an array of new particles that could answer some of the most fundamental questions of all time. The current baseline design allows for an upgrade to a 50-kilometre, 1 trillion-electron-volt (TeV) machine during the second stage of the project. This reference design provides the first detailed technical snapshot of the proposed future electron-positron collider, defining in detail the technical parameters and components that make up each section of the 31-kilometer long accelerator. The report will guide the development of the worldwide R&D program, motivate international industrial studies and serve as the basis for the final engineering design needed to make an official project proposal later this decade.

  4. Determination of tin(II) in reagents for radiopharmaceuticals

    International Nuclear Information System (INIS)

    Morosanova, E.I.; Loginova, K. A.; Epstein, N.B.

    2003-01-01

    The goal of this work is to elaborate a procedure for rapid and simple determination of tin(II) in reagents for preparation of radiopharmaceuticals based on a system albumin-Tc-99m. Original test tools for the determination of various analytes have been suggested in our lab based on the use of small glass tubes (1-2 mm i.d. - 50-70 mm) filled with indicator powders containing suitable immobilized chromogenic reagents. An analytical signal (a length of colored zone which is proportional to the concentration of an analyte) is detected after a sample passing through the indicator tube. Heteropoly compounds are well-known analytical reagents for a photometric determination of various reductants. For elaboration of indicator tubes abilities of Mo,P-heteropoly compounds to give deeply colored blue compounds after reduction were used. (authors)

  5. Stability study for magnetic reagent assaying Hb and HbA1c

    International Nuclear Information System (INIS)

    Hsieh, Wen-Pin; Chieh, J.J.; Yang, C.C.; Yang, S.Y.; Chen, Po-Yu; Huang, Yu-Hao; Hong, Y.W.; Horng, H.E.

    2013-01-01

    Reagents for magnetically labeled immunoassay on human Hb and human HbA1c have been synthesized. The reagents consist of Fe 3 O 4 magnetic particles biofunctionalized with antibodies against Hb and HbA1c. It has been demonstrated that the reagents can be applied to quantitatively detect Hb and HbA1c by using immunomagnetic reduction assay. In addition to characterizing the assay properties, such as the standard curve and the low-detection limit, the stability of reagents is investigated. To do this, the temporal dependence of particle sizes and the bio-activity of reagents are monitored. The results show that the reagents are highly stable when stored at 2–8 °C. This means that the reagents synthesized in this work are promising for practical applications. - Highlights: ► The properties of assaying Hb and HbA1c using immunomagnetic reduction are studied. ► The magnetic nanoparticles with antibodies are highly stable in solutions. ► No significant mutual interference between Hb and HbA1c in assays is observed. ► High-sensitivity assays on Hb and HbA1c using immunomagnetic reduction are achieved.

  6. OPTICAL SPECTRA OF CANDIDATE INTERNATIONAL CELESTIAL REFERENCE FRAME (ICRF) FLAT-SPECTRUM RADIO SOURCES

    Energy Technology Data Exchange (ETDEWEB)

    Titov, O.; Stanford, Laura M. [Geoscience Australia, P.O. Box 378, Canberra, ACT 2601 (Australia); Johnston, Helen M.; Hunstead, Richard W. [Sydney Institute for Astronomy, School of Physics, University of Sydney, NSW 2006 (Australia); Pursimo, T. [Nordic Optical Telescope, Nordic Optical Telescope Apartado 474E-38700 Santa Cruz de La Palma, Santa Cruz de Tenerife (Spain); Jauncey, David L. [CSIRO Astronomy and Space Science, ATNF and Research School of Astronomy and Astrophysics, Australian National University, Canberra, ACT 2611 (Australia); Maslennikov, K. [Central Astronomical Observatory at Pulkovo, Pulkovskoye Shosse, 65/1, 196140, St. Petersburg (Russian Federation); Boldycheva, A., E-mail: oleg.titov@ga.gov.au [Ioffe Physical Technical Institute, 26 Polytekhnicheskaya, St. Petersburg, 194021 (Russian Federation)

    2013-07-01

    Continuing our program of spectroscopic observations of International Celestial Reference Frame (ICRF) sources, we present redshifts for 120 quasars and radio galaxies. Data were obtained with five telescopes: the 3.58 m European Southern Observatory New Technology Telescope, the two 8.2 m Gemini telescopes, the 2.5 m Nordic Optical Telescope (NOT), and the 6.0 m Big Azimuthal Telescope of the Special Astrophysical Observatory in Russia. The targets were selected from the International VLBI Service for Geodesy and Astrometry candidate International Celestial Reference Catalog which forms part of an observational very long baseline interferometry (VLBI) program to strengthen the celestial reference frame. We obtained spectra of the potential optical counterparts of more than 150 compact flat-spectrum radio sources, and measured redshifts of 120 emission-line objects, together with 19 BL Lac objects. These identifications add significantly to the precise radio-optical frame tie to be undertaken by Gaia, due to be launched in 2013, and to the existing data available for analyzing source proper motions over the celestial sphere. We show that the distribution of redshifts for ICRF sources is consistent with the much larger sample drawn from Faint Images of the Radio Sky at Twenty cm (FIRST) and Sloan Digital Sky Survey, implying that the ultra-compact VLBI sources are not distinguished from the overall radio-loud quasar population. In addition, we obtained NOT spectra for five radio sources from the FIRST and NRAO VLA Sky Survey catalogs, selected on the basis of their red colors, which yielded three quasars with z > 4.

  7. Production of reference enteroviruses.

    Science.gov (United States)

    Kalter, S S; Rodriguez, A R; Armour, V

    1968-10-01

    Forty-five human enterovirus reagents of certified purity and quality were prepared for use as seed viruses and as immunizing antigens. One of the reagents was ampouled as "untreated" seed virus, whereas 14 were ampouled as "MgCl(2)-stabilized" reagents. The remaining 30 reagents were ampouled as "untreated" seed viruses and as "MgCl(2)-stabilized" reagents. Thirty of the reagents were propagated on primary African green monkey kidney cells, 3 on primary baboon kidney cells, 3 on primary rhesus monkey kidney cells, and the remaining 9 on human amnion cells. Forty-two of the viral antigens were concentrated for use in the production of high-titered specific antisera in large animals.

  8. The HLA-DP polymorphism in Denmark investigated by local and international PLT reagents. Definition of two "new" DP antigens

    DEFF Research Database (Denmark)

    Ødum, Niels; Hartzman, R; Jakobsen, B K

    1986-01-01

    Lymphocytes from highly selected donors were primed for 10 days and subsequently bulk-expanded in IL 2 (TCGF) containing cultures. Two well-discriminatory PLT (CDP = Copenhagen DP) reagents against each of the DPw1-w6 specificities and one against each of the two "new" specificities, CDP4s...

  9. Reverse flow injection spectrophotometric determination of ciprofloxacin in pharmaceuticals using iron from soil as a green reagent

    Science.gov (United States)

    Palamy, Sysay; Ruengsitagoon, Wirat

    2018-02-01

    A novel reverse flow injection spectrophotometric method for the determination of ciprofloxacin was successfully combined with the on-line introduction of an iron solution extracted from soil as green reagent. The assay was optimized by a univariate method to select the optimum conditions for the highest absorbance and highest stability of the complex. Beer-Lambert's law (λmax = 440 nm) is obeyed in the range 0.5-50 μg mL- 1 with a correlation coefficient (r2) of 0.9976 and 0.9996 using soil as green reagent from Khon Kaen, Thailand and Vientiane, Laos, respectively. The average percentage recoveries were in the range of 98.55-102.14% and the precision was in the range of 0.80-1.73%. The limit of detection and the limit of quantitation were 0.20 and 0.69 μg mL- 1, respectively, with a sampling rate of over 46 samples h- 1. The method was successfully applied to the determination of ciprofloxacin in commercial pharmaceutical formulations. The results were in good agreement with those obtained by the reference HPLC method using a t-test at 95% of confidence level for comparison. This method is suitable for laboratories looking for alternative analytical methods using green reagents.

  10. Stability study for magnetic reagent assaying Hb and HbA1c

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Wen-Pin [Actherm Inc., Hsinchu 200, Taiwan (China); Chieh, J.J.; Yang, C.C. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Yang, S.Y. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); MagQu Co., Ltd., Sindian Dist., New Taipei City 231, Taiwan (China); Chen, Po-Yu; Huang, Yu-Hao [Actherm Inc., Hsinchu 200, Taiwan (China); Hong, Y.W. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Horng, H.E., E-mail: phyfv001@ntnu.edu.tw [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China)

    2013-01-15

    Reagents for magnetically labeled immunoassay on human Hb and human HbA1c have been synthesized. The reagents consist of Fe{sub 3}O{sub 4} magnetic particles biofunctionalized with antibodies against Hb and HbA1c. It has been demonstrated that the reagents can be applied to quantitatively detect Hb and HbA1c by using immunomagnetic reduction assay. In addition to characterizing the assay properties, such as the standard curve and the low-detection limit, the stability of reagents is investigated. To do this, the temporal dependence of particle sizes and the bio-activity of reagents are monitored. The results show that the reagents are highly stable when stored at 2-8 Degree-Sign C. This means that the reagents synthesized in this work are promising for practical applications. - Highlights: Black-Right-Pointing-Pointer The properties of assaying Hb and HbA1c using immunomagnetic reduction are studied. Black-Right-Pointing-Pointer The magnetic nanoparticles with antibodies are highly stable in solutions. Black-Right-Pointing-Pointer No significant mutual interference between Hb and HbA1c in assays is observed. Black-Right-Pointing-Pointer High-sensitivity assays on Hb and HbA1c using immunomagnetic reduction are achieved.

  11. Prediction of total electron content using the international reference ionosphere

    International Nuclear Information System (INIS)

    Mcnamara, L.F.

    1984-01-01

    It is pointed out that the International Reference Ionosphere (IRI) is an empirical model of the ionosphere based on experimental observations. Rawer et al. (1978) have discussed the goals and status of the IRI. The aim of the IRI is related to the establishment of a compendium of height profiles through the ionosphere for the four main parameters, taking into account plasma density, temperature of ions and electrons, and ion composition. The present model is inadequate in some areas, and the IRI working group has encouraged tests of the model's validity. The present investigation is concerned with a test of the model's ability to reproduce observations of total electron content (TEC) over a wide range of conditions. The TEC observations were obtained with the aid of the Faraday rotation technique, which provides the TEC out to about 2000 km. Tests using the Bent ionospheric model indicate that the altitude range 1000 to 2000 km contributes up to five percent of the TEC. 12 references

  12. A study to establish international diagnostic reference levels for paediatric computed tomography

    International Nuclear Information System (INIS)

    Vassileva, J.; Rehani, M.; Kostova-Lefterova, D.; Al-Naemi, H.M.; Al Suwaidi, J.S.; Arandjic, D.; Bashier, E.H.O.; Kodlulovich Renha, S.; El-Nachef, L.; Aguilar, J.G.; Gershan, V.; Gershkevitsh, E.; Gruppetta, E.; Hustuc, A.; Jauhari, A.; Hassan Kharita, Mohammad; Khelassi-Toutaoui, N.; Khosravi, H.R.; Khoury, H.; Kralik, I.; Mahere, S.; Mazuoliene, J.; Mora, P.; Muhogora, W.; Muthuvelu, P.; Nikodemova, D.; Novak, L.; Pallewatte, A.; Pekarovic, D.; Shaaban, M.; Shelly, E.; Stepanyan, K.; Thelsy, N.; Visrutaratna, P.; Zaman, A.

    2015-01-01

    The article reports results from the largest international dose survey in paediatric computed tomography (CT) in 32 countries and proposes international diagnostic reference levels (DRLs) in terms of computed tomography dose index (CTDI vol ) and dose length product (DLP). It also assesses whether mean or median values of individual facilities should be used. A total of 6115 individual patient data were recorded among four age groups: <1 y, >1-5 y, >5-10 y and >10-15 y. CTDI w , CTDI vol and DLP from the CT console were recorded in dedicated forms together with patient data and technical parameters. Statistical analysis was performed, and international DRLs were established at rounded 75. percentile values of distribution of median values from all CT facilities. The study presents evidence in favour of using median rather than mean of patient dose indices as the representative of typical local dose in a facility, and for establishing DRLs as third quartile of median values. International DRLs were established for paediatric CT examinations for routine head, chest and abdomen in the four age groups. DRLs for CTDI vol are similar to the reference values from other published reports, with some differences for chest and abdomen CT. Higher variations were observed between DLP values, based on a survey of whole multi-phase exams. It may be noted that other studies in literature were based on single phase only. DRLs reported in this article can be used in countries without sufficient medical physics support to identify non-optimised practice. Recommendations to improve the accuracy and importance of future surveys are provided. (authors)

  13. On extraction reagents for hydrometallurgy

    International Nuclear Information System (INIS)

    Zolotov, Yu.A.

    1975-01-01

    Fundamental requirements to the extractants are considered. Ways of obtaining selective extractants are discussed in particular on the basis of coordination chemistry achivements. Attention is drawn to expediency of study (as extractants) of flotation reagents, additions to the oil, pesticides, accelerators of caoutchouc vulcanization

  14. Development of versatile universal reagent immunoradiometric assay technique

    International Nuclear Information System (INIS)

    Hazra, D.K.

    1982-10-01

    Immunoradiometric assays, which make use of labelled antibodies, potentially offer better sensitivity and specificity than do radioimmunoassays, which use labelled antigens. In addition, they can in principle be performed in a particularly convenient scheme wherein the same labelled reagent may be used for many different analytes - thus serving as a ''universal'' labelled reagent. Thus if the specific antibody for every analyte is raised in rabbits, and an anti-rabbit antibody is labelled, the latter may be added after the specific antibody to quantify the amount of specific antibody bound to analyte and thereby the amount of analyte present. The potential greater sensitivity and specificity of the immunoradiometric procedure, coupled with the potential convenience of the ''universal'' labelled reagent, might allow such immunoradiometric techniques to be used effectively in the study of communicable diseases in developing countries. Development of these procedures was the subject of this investigation. Many components of these procedures had to be explored and provisionally optimized, including coating of assay tubes with ''extraction'' antibody, immunological purification of antibodies, labelling of antibodies, and intermediate steps toward these goals. Applications were thereupon tested using those provisionally optimized components. The ''universal'' labelled reagent, a donkey anti-rabbit antiserum, was successfully used in the assay of TSH; however, cross reactions of the reagent with non-rabbit immunoglobulins and other materials present seriously limited the sensitivity of the method. Using conventional immunoradiometric procedures, circulating TB and amoebic antibodies could be detected in patients suffering from these diseases. Similarly, circulating antigens in the same patients could also be detected, but not with sufficient sensitivity and specificity to provide a reliable analytical system. Numerous improvements will be required before these techniques

  15. Review Article: Toxic Effects of Some Reagents Used in Electron ...

    African Journals Online (AJOL)

    Ultrathin sections prepared for electron microscopy and histochemistry are indispensable in cytological, histological and histochemical studies. The paper discusses the various reagents used in these fields of study. Unfortunately, these reagents and chemicals are hazardous to health. There is wisdom in informing the ...

  16. Reagents for the assay of cardenolide glycosides and aglycones

    International Nuclear Information System (INIS)

    Wilkinson, S.

    1976-01-01

    Some novel reagents are described for use in the radioimmunoassay of the 3-glycone derivatives of cardenolides (cardiac glycosides) and more especially digoxin, digitoxin, gitoxin, periplocin and lanatosides. Using these reagents these cardenolides and their derivatives may be assayed both in aqueous solution and in urine. A method is also described for performing such assays, including a suitable kit. (U.K.)

  17. Investigation of cleaning reagents for calcium chromate spills

    International Nuclear Information System (INIS)

    Dillard, B.M.

    1979-01-01

    Cleaning of calcium chromate spills can be a problem due to the insolubility of the material and the corrosiveness of several possible cleaning agents on the stainless steel equipment. Because of OSHA Standards for Cr(VI) exposure, it is necessary to remove spills as efficiently as possible in order to prevent the contaminant from becoming airborne. This study involved the comparison of several possible cleaning agents by studying the solubility of calcium chromate in each reagent. Two general types of reagents for dissolution of calcium chromate were investigated; those which act by conversion of the insoluble calcium chromate to a more soluble salt and to H 2 CrO 4 , and those which appear to act as complexing agents and thereby dissolve the calcium chromate. The most efficient of the reagents investigated was hydrochloric acid. However, even dilute solutions of halide acids destroy passivity of stainless steel causing pitting and stress-corrosion. Acetic acid and nitric acid were somewhat less efficient than hydrochloric acid in dissolving calcium chromate. However, both reagents are noncorrosive with stainless steel, nitric acid tending to favor passivity of the materials. Therefore, it is recommended that dilute solutions of either of these two acids be used for removal of calcium chromate spills in conjunction with mechanical methods that might be necessary, depending on the magnitude of the spill

  18. Impact of quasar proper motions on the alignment between the International Celestial Reference Frame and the Gaia reference frame

    Science.gov (United States)

    Liu, J.-C.; Malkin, Z.; Zhu, Z.

    2018-03-01

    The International Celestial Reference Frame (ICRF) is currently realized by the very long baseline interferometry (VLBI) observations of extragalactic sources with the zero proper motion assumption, while Gaia will observe proper motions of these distant and faint objects to an accuracy of tens of microarcseconds per year. This paper investigates the difference between VLBI and Gaia quasar proper motions and it aims to understand the impact of quasar proper motions on the alignment of the ICRF and Gaia reference frame. We use the latest time series data of source coordinates from the International VLBI Service analysis centres operated at Goddard Space Flight Center (GSF2017) and Paris observatory (OPA2017), as well as the Gaia auxiliary quasar solution containing 2191 high-probability optical counterparts of the ICRF2 sources. The linear proper motions in right ascension and declination of VLBI sources are derived by least-squares fits while the proper motions for Gaia sources are simulated taking into account the acceleration of the Solar system barycentre and realistic uncertainties depending on the source brightness. The individual and global features of source proper motions in GSF2017 and OPA2017 VLBI data are found to be inconsistent, which may result from differences in VLBI observations, data reduction and analysis. A comparison of the VLBI and Gaia proper motions shows that the accuracies of the components of rotation and glide between the two systems are 2-4 μas yr- 1 based on about 600 common sources. For the future alignment of the ICRF and Gaia reference frames at different wavelengths, the proper motions of quasars must necessarily be considered.

  19. Use of Competition Kinetics with Fast Reactions of Grignard Reagents

    DEFF Research Database (Denmark)

    Holm, Torkil

    2000-01-01

    small.This is concluded from experiments in which results obtained by competition kinetics are compared with results obtained directly by flow stream procedures. A clearer picture of the reactivity ratios is obtained when the highly reactive reagent is highly diluted with its competitor. A fast reagent...

  20. Proposal of a candidate international conventional reference measurement procedure for free thyroxine in serum.

    NARCIS (Netherlands)

    Thienpont, L.M.; Beastall, G.H.; Christofides, N.D.; Faix, J.D.; Ieiri, T.; Jarrige, V.; Miller, W.G.; Miller, R.; Nelson, J.C.; Ronin, C.; Ross, H.A.; Rottmann, M.; Thijssen, J.H.; Toussaint, B.

    2007-01-01

    In the present paper the IFCC WG-STFT recommends and provides the rationale to establish metrological traceability of serum free thyroxine (FT4) measurements to a candidate international conventional reference measurement procedure. It is proposed that this procedure be based on equilibrium dialysis

  1. Height, weight and BMI percentiles and nutritional status relative to the international growth references among Pakistani school-aged children

    Directory of Open Access Journals (Sweden)

    Mushtaq Muhammad Umair

    2012-03-01

    Full Text Available Abstract Background Child growth is internationally recognized as an important indicator of nutritional status and health in populations. This study was aimed to compare age- and gender-specific height, weight and BMI percentiles and nutritional status relative to the international growth references among Pakistani school-aged children. Methods A population-based study was conducted with a multistage cluster sample of 1860 children aged five to twelve years in Lahore, Pakistan. Smoothed height, weight and BMI percentile curves were obtained and comparison was made with the World Health Organization 2007 (WHO and United States' Centers for Disease Control and Prevention 2000 (USCDC references. Over- and under-nutrition were defined according to the WHO and USCDC references, and the International Obesity Task Force (IOTF cut-offs. Simple descriptive statistics were used and statistical significance was considered at P Results Height, weight and BMI percentiles increased with age among both boys and girls, and both had approximately the same height and a lower weight and BMI as compared to the WHO and USCDC references. Mean differences from zero for height-, weight- and BMI-for-age z score values relative to the WHO and USCDC references were significant (P Conclusion Pakistani school-aged children significantly differed from the WHO and USCDC references. However, z score means relative to the WHO reference were closer to zero and the present study as compared to the USCDC reference. Overweight and obesity were significantly higher while underweight and thinness/wasting were significantly lower relative to the WHO reference as compared to the USCDC reference and the IOTF cut-offs. New growth charts for Pakistani children based on a nationally representative sample should be developed. Nevertheless, shifting to use of the 2007 WHO child growth reference might have important implications for child health programs and primary care pediatric clinics.

  2. The International Decision Support Initiative Reference Case for Economic Evaluation: An Aid to Thought.

    Science.gov (United States)

    Wilkinson, Thomas; Sculpher, Mark J; Claxton, Karl; Revill, Paul; Briggs, Andrew; Cairns, John A; Teerawattananon, Yot; Asfaw, Elias; Lopert, Ruth; Culyer, Anthony J; Walker, Damian G

    2016-12-01

    Policymakers in high-, low-, and middle-income countries alike face challenging choices about resource allocation in health. Economic evaluation can be useful in providing decision makers with the best evidence of the anticipated benefits of new investments, as well as their expected opportunity costs-the benefits forgone of the options not chosen. To guide the decisions of health systems effectively, it is important that the methods of economic evaluation are founded on clear principles, are applied systematically, and are appropriate to the decision problems they seek to inform. The Bill and Melinda Gates Foundation, a major funder of economic evaluations of health technologies in low- and middle-income countries (LMICs), commissioned a "reference case" through the International Decision Support Initiative (iDSI) to guide future evaluations, and improve both the consistency and usefulness to decision makers. The iDSI Reference Case draws on previous insights from the World Health Organization, the US Panel on Cost-Effectiveness in Health Care, and the UK National Institute for Health and Care Excellence. Comprising 11 key principles, each accompanied by methodological specifications and reporting standards, the iDSI Reference Case also serves as a means of identifying priorities for methods research, and can be used as a framework for capacity building and technical assistance in LMICs. The iDSI Reference Case is an aid to thought, not a substitute for it, and should not be followed slavishly without regard to context, culture, or history. This article presents the iDSI Reference Case and discusses the rationale, approach, components, and application in LMICs. Copyright © 2016 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  3. Mössbauer spectroscopy research of interaction of alumosilicic reagent and iron dissolved in water

    International Nuclear Information System (INIS)

    Feklistov, D Y; Filippov, V P; Kurchatov, I M; Laguntsov, N I; Salomasov, V A; Permyakov, Yu V

    2016-01-01

    The aim of this work is to reveal the results of alumosilicic reagent interaction with iron compounds contained in the water. This reagent is simultaneously coagulant-flocculant and adsorbent. The iron atoms state is studied in the reagent and in reacted sediment. The valence state of iron atoms are determined in the reagents and sediments. The existence of iron containing superparamagnetic particles in the sediment is shown. (paper)

  4. Lanthanide shift reagents, binding, shift mechanisms and exchange

    International Nuclear Information System (INIS)

    Boer, J.W.M. de

    1977-01-01

    Paramagnetic lanthanide shift reagents, when added to a solution of a substrate, induce shifts in the nuclear magnetic resonance (NMR) spectrum of the substrate molecules. The induced shifts contain information about the structure of the shift reagent substrate complex. The structural information, however, may be difficult to extract because of the following effects: (1) different complexes between shift reagent and substrate may be present in solution, e.g. 1:1 and 1:2 complexes, and the shift observed is a weighed average of the shifts of the substrate nuclei in the different complexes; (2) the Fermi contact interaction, arising from the spin density at the nucleus, contributes to the induced shift; (3) chemical exchange effects may complicate the NMR spectrum. In this thesis, the results of an investigation into the influence of these effects on the NMR spectra of solutions containing a substrate and LSR are presented. The equations describing the pseudo contact and the Fermi contact shift are derived. In addition, it is shown how the modified Bloch equations describing the effect of the chemical exchange processes occurring in the systems studied can be reduced to the familiar equations for a two-site exchange case. The binding of mono- and bifunctional ethers to the shift reagent are reported. An analysis of the induced shifts is given. Finally, the results of the experiments performed to study the exchange behavior of dimethoxyethane and heptafluorodimethyloctanedionato ligands are presented

  5. Non-proliferation through effective international control, with particular reference to peaceful uses of nuclear material as a result of nuclear disarmament and international control of plutonium

    International Nuclear Information System (INIS)

    Imai, Ryukichi

    1993-01-01

    The role of nuclear factors in the international political situation has changed. The emphasis is now on the new circumstance of the post cold-war world. Non-proliferation is dealt with through effective international control, with particular reference to peaceful uses of nuclear material as a result of nuclear weapons dismantling and international control of plutonium

  6. Organic-soluble lanthanide nuclear magnetic resonance shift reagents for sulfonium and isothiouronium salts

    International Nuclear Information System (INIS)

    Wenzel, T.J.; Zaia, J.

    1987-01-01

    Lanthanide complexes of the formula [Ln(fod) 4 ] - (FOD, 6,6,7,7,8,8,8-heptafluoro-2,2-dimethyl-3,5-octanedione) are effective organic-soluble nuclear magnetic resonance shift reagents for sulfonium and isothiouronium salts. The shift reagent is formed in solution from Ln(fod) 3 and Ag(fod) or K(fod). The selection of Ag(fod) or K(fod) in forming the shift reagent is dependent on the anion of the organic salt. Ag(fod) is more effective with halide salts, whereas K(fod) is preferred with tetrafluoroborate salts. Resolution of diastereotopic hydrogen atoms was observed in the shifted spectra of certain substrates. Enantiomeric resolution was obtained in the spectrum of sec-butylisothiouronium chloride with a chiral shift reagent. The reagents can be employed in solvents such as chloroform and benzene

  7. New sorption-reagent materials for decontamination of liquid radioactive waste

    International Nuclear Information System (INIS)

    Avramenko, V.A.; Golikov, A.P.; Zheleznov, V.V.; Kaplun, E.V.; Marinin, D.V.; Sokolnitskaya, T.A.

    2001-01-01

    Full text: Use of selective sorbents in liquid radioactive waste (LRW) management is widely spread in the field of nuclear power objects liquid waste decontamination, since the main objective there is to remove long-lived radionuclides of the nuclear cycle. The latter include, first of all, cesium-137, strontium-90, cobalt-60 and a number of α-irradiators. In this case LRW composition for most of the nuclear power objects is rather simple, except acidic deactivation solutions. At the same time, liquid radioactive wastes of different research centers have a variable chemical and radiochemical composition depending on objectives and tasks of a given center research activities. As a result, application of sorption technologies in such waste decontamination determines special requirements to these sorbents selectivity: a wide spectrum of radionuclides that can be removed and fairly high selectivity enabling to remove radionuclides from solutions of complex chemical composition (containing surfactants, complexing agents etc.). This paper is concerned with studying properties of new materials selective to different radionuclides. These materials are capable to interact with solution components whether already contained in the waste or deliberately added into resulting solution. Such sorption-reagent materials combine universal character of co-precipitation methods with simplicity of sorption methods. In this work we studied sorption-reagent inorganic ion-exchange materials interacting with sulfate-, carbonate-, oxalate-, sulfide-, and permanganate-ions. Insoluble compounds formed as a result of this interaction increase tens- and hundreds-fold the sorption selectivity of different radionuclides - strontium, cobalt, mercury, iron, and manganese as compared to conventional ion-exchange system. By means of X-ray phase analysis, IR-spectroscopy, chemical and radiochemical analysis, we have studied the mechanism of radionuclide sorption on different sorption-reagent

  8. Development of discrete choice model considering internal reference points and their effects in travel mode choice context

    Science.gov (United States)

    Sarif; Kurauchi, Shinya; Yoshii, Toshio

    2017-06-01

    In the conventional travel behavior models such as logit and probit, decision makers are assumed to conduct the absolute evaluations on the attributes of the choice alternatives. On the other hand, many researchers in cognitive psychology and marketing science have been suggesting that the perceptions of attributes are characterized by the benchmark called “reference points” and the relative evaluations based on them are often employed in various choice situations. Therefore, this study developed a travel behavior model based on the mental accounting theory in which the internal reference points are explicitly considered. A questionnaire survey about the shopping trip to the CBD in Matsuyama city was conducted, and then the roles of reference points in travel mode choice contexts were investigated. The result showed that the goodness-of-fit of the developed model was higher than that of the conventional model, indicating that the internal reference points might play the major roles in the choice of travel mode. Also shown was that the respondents seem to utilize various reference points: some tend to adopt the lowest fuel price they have experienced, others employ fare price they feel in perceptions of the travel cost.

  9. Polymer-supported reagents with enhanced metal ion recognition: Application to separations science

    International Nuclear Information System (INIS)

    Alexandratos, S.D.

    1993-01-01

    The design and development of polymer-supported reagents with ever-increasing specificities for targeted metal ions remains an important areas of research. The need for efficient separation schemes for both ions and molecules has been outlined in a report by the National Research Council (King) and will gain increased emphasis as environmental restoration is pursued. Polymer-supported reagents are unique in their ability to be applied in an environmentally benign manner to a host of challenges. Such reagents, in the form of beads, can be applied to continuous separation processes ranging from the removal of metal ions in water to the recovery of medicinal drugs produced through biotechnological means. The application of polymer-supported reagents to metal ion separations still requires developing a fundamental understanding of ligand-metal interactions, the role of the polymer in those interactions, and the methods of synthesizing such polymeric reagents in a readily applicable form. Ion exchange resins with sulfonic acid ligands are the prototypical polymer-supported reagents, and their properties have been exhaustively studied (Helfferich). The high acidity of the sulfonic acid group, however, precludes much selectivity, and it displays a very limited range of reaction free energy values with different metal ions (Boyd et al.). The carboxylic acid ligand, present in the acrylate resins, is more selective, though its weak acidity requires relatively high pH solutions for it to be effective. Research has thus been focused on the preparation of polymer-supported reagents with high levels of specificity for targeted metal ions

  10. Reagent conditions of the flotation of copper, copper - molybdenum and copper -zinc ores in foreing countries

    International Nuclear Information System (INIS)

    Nevaeva, L.M.

    1983-01-01

    Reagents-collectors and frothers, used abroad in reagent regimes of flotation of copper, copper-molybdenum and copper zinc ores, have been considered. Xanthogenates, aerofloats, xanthogenformiates, thionocarbamates are mainly used as reagents-collectors. Methylizobutylcarbinol and Daufros are used as reagents-frothers

  11. 21 CFR 866.3120 - Chlamydia serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3120 Chlamydia... and antisera used in serological tests to identify antibodies to chlamydia in serum. Additionally...

  12. 21 CFR 866.3490 - Rhinovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3490 Rhinovirus... and antisera used in serological tests to identify antibodies to rhinovirus in serum. The...

  13. 21 CFR 866.3020 - Adenovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3020 Adenovirus... identify adenoviruses directly from clinical specimens. The identification aids in the diagnosis of disease...

  14. 21 CFR 866.3205 - Echovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3205 Echovirus... echoviruses from clinical specimens or from tissue culture isolates derived from clinical specimens. The...

  15. Comparative studies on extracts from Hericium erinaceus by different polarity reagents to gain higher antioxidant activities.

    Science.gov (United States)

    Jiang, Shengjuan; Wang, Yuliang; Zhang, Xiaolong

    2016-07-01

    Hericium erinaceus (H. erinaceus) is a source of exogenous antioxidants that has been traditionally used in China for the prevention and treatment of oxidative stress-associated disease. In the present study, the bioactive compounds of H. erinaceus were extracted with the following eight representative reagents: n-Hexane, xylene, chloroform, anhydrous ether, ethyl acetate, acetone, anhydrous ethanol and distilled water. The in vitro antioxidant activities were also evaluated. All of the extracted compounds exhibited reducing power and scavenging activity against 1-diphenyl-2-picrylhydrazyl (DPPH) and superoxide anion free radicals. In addition, the antioxidant capacities varied with the used chemical reagents and exhibited dose-dependent effects. Extracts from anhydrous ethanol, chloroform and acetone were capable of inhibiting lipid peroxidation. The anhydrous ethanol extracts were observed to have significant levels of antioxidant compounds since they had a strong reducing power, high scavenging rates against DPPH and superoxide anion-free radicals (>90%), and high inhibition rates on lipid peroxidation (>60%). The present study will provide reference data for the antioxidant applications of H. erinaceus in pharmaceutical use and disease prevention.

  16. International linear collider reference design report 2007

    International Nuclear Information System (INIS)

    Aarons, G.

    2007-01-01

    The International Linear Collider will give physicists a new cosmic doorway to explore energy regimes beyond the reach of today's accelerators. A proposed electron-positron collider, the ILC will complement the Large Hadron Collider, a proton-proton collider at the European Center for Nuclear Research (CERN) in Geneva, Switzerland, together unlocking some of the deepest mysteries in the universe. With LHC discoveries pointing the way, the ILC -- a true precision machine -- will provide the missing pieces of the puzzle. Consisting of two linear accelerators that face each other, the ILC will hurl some 10 billion electrons and their anti-particles, positrons, toward each other at nearly the speed of light. Superconducting accelerator cavities operating at temperatures near absolute zero give the particles more and more energy until they smash in a blazing crossfire at the centre of the machine. Stretching approximately 35 kilometres in length, the beams collide 14,000 times every second at extremely high energies -- 500 billion-electron-volts (GeV). Each spectacular collision creates an array of new particles that could answer some of the most fundamental questions of all time. The current baseline design allows for an upgrade to a 50-kilometre, 1 trillion-electron-volt (TeV) machine during the second stage of the project. This reference design provides the first detailed technical snapshot of the proposed future electron-positron collider, defining in detail the technical parameters and components that make up each section of the 31-kilometer long accelerator. The report will guide the development of the worldwide R and D program, motivate international industrial studies and serve as the basis for the final engineering design needed to make an official project proposal later this decade

  17. Reagent precipitation of copper ions from wastewater of machine-building factories

    Science.gov (United States)

    Porozhnyuk, L. A.; Lupandina, N. S.; Porozhnyuk, E. V.

    2018-03-01

    The article presents the results of reagent removal of copper ions from wastewater of machine-building factories. The urgency of the study is conditioned by the widening of the range of effective reagents through the implementation of industrial waste. The investigation covers mineralogical and fractional composition of chalk enrichment waste. In the work, the conditions of thermal activation of chalk enrichment waste used for reagent removal of copper ions from wastewater were elaborated. It was shown that the thermal activation of waste facilitates the increased treatment efficacy up to the set sanitation, hygiene and technological standards.

  18. A importância da qualidade da água reagente no laboratório clínico The importance of water quality in clinical laboratory reagent

    Directory of Open Access Journals (Sweden)

    Maria Elizabete Mendes

    2011-06-01

    Full Text Available A água é um reagente utilizado na maioria dos testes laboratoriais e por isso deve seguir um padrão de controle de qualidade rigoroso. O fornecimento urbano de água apresenta moléculas orgânicas, íons inorgânicos, partículas, coloides, gases, bactérias e seus produtos, que podem alterar os resultados dos exames laboratoriais e causar eventuais erros e falhas mecânicas em equipamentos analíticos. Para remover essas impurezas, é necessário recorrer a uma combinação de tecnologias de purificação. Há várias organizações que especificam normas sobre a água reagente, a fim de minimizar sua interferência nos ensaios laboratoriais. A maioria dos laboratórios utiliza as normas estabelecidas pelo Clinical and Laboratory Standards Institute (CLSI que classifica a água em: clinical laboratory reagent water (CLRW, special reagent water (SRW e instrumental feed water (IFW. O monitoramento da qualidade é realizado pela determinação de resistividade, condutividade, carbono orgânico total (TOC, controle microbiológico e endotoxinas. Os parâmetros são avaliados de acordo com a periodicidade estabelecida pela norma utilizada. Neste artigo, discutem-se a importância da água utilizada nos procedimentos laboratoriais, o controle da qualidade e as interferências nos ensaios laboratoriais.Water is a reagent used in most laboratory tests and, therefore, must follow stringent quality control standards. The urban water supply has organic molecules, inorganic ions, particles, colloids, gases, bacteria and their products, which may alter laboratory test results and cause occasional errors and mechanical failures in diagnostic equipment. To remove these impurities, it is necessary to use a combination of purification technologies. There are several organizations that specify reagent water standards to minimize its interference in laboratory assays. Most laboratories set standards established by the Clinical and Laboratory Standards

  19. 21 CFR 866.3470 - Reovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3470 Reovirus... and antisera used in serological tests to identify antibodies to reovirus in serum. The identification...

  20. 21 CFR 864.9650 - Quality control kit for blood banking reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Quality control kit for blood banking reagents... SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That Manufacture Blood and Blood Products § 864.9650 Quality control kit for blood banking reagents. (a...

  1. Rapid heteroatom transfer to arylmetals utilizing multifunctional reagent scaffolds

    Science.gov (United States)

    Gao, Hongyin; Zhou, Zhe; Kwon, Doo-Hyun; Coombs, James; Jones, Steven; Behnke, Nicole Erin; Ess, Daniel H.; Kürti, László

    2017-07-01

    Arylmetals are highly valuable carbon nucleophiles that are readily and inexpensively prepared from aryl halides or arenes and widely used on both laboratory and industrial scales to react directly with a wide range of electrophiles. Although C-C bond formation has been a staple of organic synthesis, the direct transfer of primary amino (-NH2) and hydroxyl (-OH) groups to arylmetals in a scalable and environmentally friendly fashion remains a formidable synthetic challenge because of the absence of suitable heteroatom-transfer reagents. Here, we demonstrate the use of bench-stable N-H and N-alkyl oxaziridines derived from readily available terpenoid scaffolds as efficient multifunctional reagents for the direct primary amination and hydroxylation of structurally diverse aryl- and heteroarylmetals. This practical and scalable method provides one-step synthetic access to primary anilines and phenols at low temperature and avoids the use of transition-metal catalysts, ligands and additives, nitrogen-protecting groups, excess reagents and harsh workup conditions.

  2. Animal-Friendly Affinity Reagents: Replacing the Needless in the Haystack.

    Science.gov (United States)

    Gray, A C; Sidhu, S S; Chandrasekera, P C; Hendriksen, C F M; Borrebaeck, C A K

    2016-12-01

    The multibillion-dollar global antibody industry produces an indispensable resource but that is generated using millions of animals. Despite the irrefutable maturation and availability of animal-friendly affinity reagents (AFAs) employing naïve B lymphocyte or synthetic recombinant technologies expressed by phage display, animal immunisation is still authorised for antibody production. Remarkably, replacement opportunities have been overlooked, despite the enormous potential reduction in animal use. Directive 2010/63/EU requires that animals are not used where alternatives exist. To ensure its implementation, we have engaged in discussions with the EU Reference Laboratory for alternatives to animal testing (EURL ECVAM) and the Directorate General for Environment to carve out an EU-led replacement strategy. Measures must be imposed to avoid outsourcing, regulate commercial production, and ensure that antibody producers are fully supported. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Decolorizing textile wastewater with Fenton's reagent electrogenerated with a solar photovoltaic cell.

    Science.gov (United States)

    Figueroa, Sandra; Vázquez, Leticia; Alvarez-Gallegos, A

    2009-02-01

    In this work it is demonstrated that Fenton's reagent can be electroproduced with abundant and cheap feedstock: oxygen saturated wastewater and solar energy. Experiments were carried out in a divided electrochemical flow cell using two electrodes: a three dimensional reticulated vitreous carbon cathode and stainless steel anode. Fenton's reagent is produced by oxygen reduction on the cathode in the presence of 1mM Fe(2+). The influence of electrolyte nature and its concentration and potential difference on the current efficiency, as well as the rate of Fenton's reagent electroproduction is discussed and it is concluded that over this extended range of conditions the current efficiency, for Fenton's reagent production, fell within the range 50-70%. It is possible to electroproduce a stoichiometric amount of Fenton reagent for the oxidation of 0.061mM Reactive Black 5 (in tap water+0.05M Na(2)SO(4), approximately pH 2.8). Similar results were obtained for solutions containing 0.1mM Acid Green 25. Some practical applications in the field of water treatment are included. The energy required for drive electrochemical reaction is supplied to the flow cell by means of a commercial solar panel.

  4. One hundred prime references on hydrogeochemical and stream sediment surveying for uranium as internationally practiced, including 60 annotated references

    International Nuclear Information System (INIS)

    Sharp, R.R. Jr.; Bolivar, S.L.

    1981-04-01

    The United States Department of Energy (DOE), formerly the US ERDA, has initiated a nationwide Hydrogeochemical and Stream Sediment Reconnaissance (HSSR). This program is part of the US National Uranium Resource Evaluation, designed to provide an improved estimate for the availability and economics of nuclear fuel resources and make available to industry information for use in exploration and development of uranium resources. The Los Alamos National Laboratory is responsible for completing the HSSR in Rocky Mountain states of New Mexico, Colorado, Wyoming, and Montana and in the state of Alaska. This report contains a compilation of 100 prime references on uranium hydrogeochemical and stream sediment reconnaissance as internationally practiced prior to 1977. The major emphasis in selection of these references was directed toward constructing a HSSR program with the purpose of identifying uranium in the Los Alamos National Laboratory area of responsibility. The context of the annotated abstracts are the authors' concept of what the respective article contains relative to uranium geochemistry and hydrogeochemical and stream sediment surveying. Consequently, in many cases, significant portions of the original articles are not discussed. The text consists of two parts. Part I contains 100 prime references, alphabetically arranged. Part II contains 60 select annotated abstracts, listed in chronological order

  5. Individualized adjustments to reference phantom internal organ dosimetry—scaling factors given knowledge of patient external anatomy

    Science.gov (United States)

    Wayson, Michael B.; Bolch, Wesley E.

    2018-04-01

    Internal radiation dose estimates for diagnostic nuclear medicine procedures are typically calculated for a reference individual. Resultantly, there is uncertainty when determining the organ doses to patients who are not at 50th percentile on either height or weight. This study aims to better personalize internal radiation dose estimates for individual patients by modifying the dose estimates calculated for reference individuals based on easily obtainable morphometric characteristics of the patient. Phantoms of different sitting heights and waist circumferences were constructed based on computational reference phantoms for the newborn, 10 year-old, and adult. Monoenergetic photons and electrons were then simulated separately at 15 energies. Photon and electron specific absorbed fractions (SAFs) were computed for the newly constructed non-reference phantoms and compared to SAFs previously generated for the age-matched reference phantoms. Differences in SAFs were correlated to changes in sitting height and waist circumference to develop scaling factors that could be applied to reference SAFs as morphometry corrections. A further set of arbitrary non-reference phantoms were then constructed and used in validation studies for the SAF scaling factors. Both photon and electron dose scaling methods were found to increase average accuracy when sitting height was used as the scaling parameter (~11%). Photon waist circumference-based scaling factors showed modest increases in average accuracy (~7%) for underweight individuals, but not for overweight individuals. Electron waist circumference-based scaling factors did not show increases in average accuracy. When sitting height and waist circumference scaling factors were combined, modest average gains in accuracy were observed for photons (~6%), but not for electrons. Both photon and electron absorbed doses are more reliably scaled using scaling factors computed in this study. They can be effectively scaled using sitting

  6. Individualized adjustments to reference phantom internal organ dosimetry-scaling factors given knowledge of patient external anatomy.

    Science.gov (United States)

    Wayson, Michael B; Bolch, Wesley E

    2018-04-13

    Internal radiation dose estimates for diagnostic nuclear medicine procedures are typically calculated for a reference individual. Resultantly, there is uncertainty when determining the organ doses to patients who are not at 50th percentile on either height or weight. This study aims to better personalize internal radiation dose estimates for individual patients by modifying the dose estimates calculated for reference individuals based on easily obtainable morphometric characteristics of the patient. Phantoms of different sitting heights and waist circumferences were constructed based on computational reference phantoms for the newborn, 10 year-old, and adult. Monoenergetic photons and electrons were then simulated separately at 15 energies. Photon and electron specific absorbed fractions (SAFs) were computed for the newly constructed non-reference phantoms and compared to SAFs previously generated for the age-matched reference phantoms. Differences in SAFs were correlated to changes in sitting height and waist circumference to develop scaling factors that could be applied to reference SAFs as morphometry corrections. A further set of arbitrary non-reference phantoms were then constructed and used in validation studies for the SAF scaling factors. Both photon and electron dose scaling methods were found to increase average accuracy when sitting height was used as the scaling parameter (~11%). Photon waist circumference-based scaling factors showed modest increases in average accuracy (~7%) for underweight individuals, but not for overweight individuals. Electron waist circumference-based scaling factors did not show increases in average accuracy. When sitting height and waist circumference scaling factors were combined, modest average gains in accuracy were observed for photons (~6%), but not for electrons. Both photon and electron absorbed doses are more reliably scaled using scaling factors computed in this study. They can be effectively scaled using sitting

  7. Differential School Contextual Effects for Math and English: Integrating the Big-Fish-Little-Pond Effect and the Internal/External Frame of Reference

    Science.gov (United States)

    Parker, Philip D.; Marsh, Herbert W.; Ludtke, Oliver; Trautwein, Ulrich

    2013-01-01

    The internal/external frame of reference and the big-fish-little-pond effect are two major models of academic self-concept formation which have considerable theoretical and empirical support. Integrating the domain specific and compensatory processes of the internal/external frame of reference model with the big-fish-little-pond effect suggests a…

  8. Calibrating NIST SRM 683 as A New International Reference Standard for Zn Isotopes

    Science.gov (United States)

    Yang, Y.; Zhang, X.; Yu, H.; Huang, F.

    2017-12-01

    Zinc isotopes have been widely applied in the cosmochemical, geochemical, and environmental studies (Moynier et al. 2017). Obtaining precise Zn isotopic data for inter-laboratory comparison is a prerequisite to these applications. Currently, the JMC3-0749L is the primary reference standard for Zn isotopes (Albarède 2004), but it is not commercially available now. Thus, it is necessary to calibrate a new international primary reference standard for Zn isotopic analysis. Chen et al. (2016) showed that NIST SRM 683 (a pure Zn metal nugget of 140 grams) has a δ66ZnJMC of 0.12‰, which is falling within the range of natural Zn isotopic compositions, and it may a good candidate for the next generation of international reference standard (Chen et al. 2016). In order to further examine whether NIST SRM 683 has a homogeneous Zn isotopic composition, we measured more NIST SRM 683 by double-spike methods using MC-ICPMS (Conway et al. 2013). The metal nuggets of NIST SRM 683 were intensively sampled by micro-drilling. Zinc isotope analyses for two nuggets show that they have δ66Zn of 0.14 ± 0.02‰ (2SD, N = 32) and 0.13 ± 0.02‰ (2SD, N = 33), respectively. These values are similar to those of two Zn metal nuggets (0.11 ± 0.02‰ vs. 0.12 ± 0.02‰) reported previously by Chen et al. (2016). We fully dissolved one nugget, producing pure Zn solution with identical Zn isotopic composition with the drilling samples. All results strongly support that NIST SRM 683 is homogeneous in Zn isotopic compositions which could be an ideal candidate for the next reference for Zn isotopes. Tests on more metal nuggets will be performed in a few months for further confirming the Zn isotope compositions and homogeneity. Reference: Albarède et al., 2004. 'The stable isotope geochemistry of copper and zinc', Reviews in Mineralogy and Geochemistry, 55: 409-27. Chen et al., 2016. 'Zinc Isotopic Compositions of NIST SRM 683 and Whole-Rock Reference Materials', Geostandards and

  9. Genotoxicity assessment of membrane concentrates of landfill leachate treated with Fenton reagent and UV-Fenton reagent using human hepatoma cell line

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Guifang [Department of Chemistry, Jinan University, Guangzhou 510632 (China); Lu, Gang [Key Laboratory of Water/Soil Toxic Pollutants Control and Bioremediation of Guangdong Higher Education Institutes, Department of Environmental Engineering, Jinan University, Guangzhou 510632 (China); Yin, Pinghe, E-mail: tyinph@jnu.edu.cn [Research Center of Analysis and Test, Jinan University, Guangzhou 510632 (China); Zhao, Ling, E-mail: zhaoling@jnu.edu.cn [Key Laboratory of Water/Soil Toxic Pollutants Control and Bioremediation of Guangdong Higher Education Institutes, Department of Environmental Engineering, Jinan University, Guangzhou 510632 (China); Jimmy Yu, Qiming [Griffith School of Engineering, Griffith University, Nathan Campus, Brisbane, Queensland 4111 (Australia)

    2016-04-15

    Highlights: • Membrane concentrates have a threat to human health and environment. • Untreated membrane concentrates induces cytotoxic and genotoxic to HepG2 cells. • Both methods were effective method for degradation of BPA and NP in concentrates. • Both methods were efficient in reducing genotoxic effects of concentrates. • UV-Fenton reagent had higher removal efficiency and provides toxicological safety. - Abstract: Membrane concentrates of landfill leachates contain organic and inorganic contaminants that could be highly toxic and carcinogenic. In this paper, the genotoxicity of membrane concentrates before and after Fenton and UV-Fenton reagent was assessed. The cytotoxicity and genotoxicity was determined by using the methods of methyltetrazolium (MTT), cytokinesis-block micronucleus (CBMN) and comet assay in human hepatoma cells. MTT assay showed a cytotoxicity of 75% after 24 h of exposure to the highest tested concentration of untreated concentrates, and no cytotoxocity for UV-Fenton and Fenton treated concentrates. Both CBMN and comet assays showed increased levels of genotoxicity in cells exposed to untreated concentrates, compared to those occurred in cells exposed to UV-Fenton and Fenton reagent treated concentrates. There was no significant difference between negative control and UV-Fenton treated concentrates for micronucleus and comet assay parameters. UV-Fenton and Fenton treatment, especially the former, were effective methods for degradation of bisphenol A and nonylphenol in concentrates. These findings showed UV-Fenton and Fenton reaction were effective methods for treatment of such complex concentrates, UV-Fenton reagent provided toxicological safety of the treated effluent, and the genotoxicity assays were found to be feasible tools for assessment of toxicity risks of complex concentrates.

  10. Genotoxicity assessment of membrane concentrates of landfill leachate treated with Fenton reagent and UV-Fenton reagent using human hepatoma cell line

    International Nuclear Information System (INIS)

    Wang, Guifang; Lu, Gang; Yin, Pinghe; Zhao, Ling; Jimmy Yu, Qiming

    2016-01-01

    Highlights: • Membrane concentrates have a threat to human health and environment. • Untreated membrane concentrates induces cytotoxic and genotoxic to HepG2 cells. • Both methods were effective method for degradation of BPA and NP in concentrates. • Both methods were efficient in reducing genotoxic effects of concentrates. • UV-Fenton reagent had higher removal efficiency and provides toxicological safety. - Abstract: Membrane concentrates of landfill leachates contain organic and inorganic contaminants that could be highly toxic and carcinogenic. In this paper, the genotoxicity of membrane concentrates before and after Fenton and UV-Fenton reagent was assessed. The cytotoxicity and genotoxicity was determined by using the methods of methyltetrazolium (MTT), cytokinesis-block micronucleus (CBMN) and comet assay in human hepatoma cells. MTT assay showed a cytotoxicity of 75% after 24 h of exposure to the highest tested concentration of untreated concentrates, and no cytotoxocity for UV-Fenton and Fenton treated concentrates. Both CBMN and comet assays showed increased levels of genotoxicity in cells exposed to untreated concentrates, compared to those occurred in cells exposed to UV-Fenton and Fenton reagent treated concentrates. There was no significant difference between negative control and UV-Fenton treated concentrates for micronucleus and comet assay parameters. UV-Fenton and Fenton treatment, especially the former, were effective methods for degradation of bisphenol A and nonylphenol in concentrates. These findings showed UV-Fenton and Fenton reaction were effective methods for treatment of such complex concentrates, UV-Fenton reagent provided toxicological safety of the treated effluent, and the genotoxicity assays were found to be feasible tools for assessment of toxicity risks of complex concentrates.

  11. 21 CFR 866.3370 - Mycobacterium tuberculosis immunofluorescent reagents.

    Science.gov (United States)

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents... used to identify Mycobacterium tuberculosis directly from clinical specimens. The identification aids...

  12. Measles serodiagnosis: production and evaluation of the IgM-measles ELISA IAL reagent Sorodiagnóstico de sarampo: produção e avaliação da técnica de ELISA IgM IAL

    Directory of Open Access Journals (Sweden)

    Sumie Hoshino-Shimizu

    2001-03-01

    Full Text Available Recent measles outbreaks in different countries led to an increase of laboratory measles diagnosis. Thus, we developed the IgM-Measles ELISA IAL, using measles virus antigens obtained from cell cultured in microcarriers in order to supply reagent kits to Brazilian public health laboratories. A batch of antigenic reagent was produced and evaluated in the enzyme immunoassay in comparison with clinical diagnosis and with as reference assay (IgM Capture ELISA CDC data. This study was performed in a positive panel with 70 serum samples from patients with measles, and a negative panel with 132 samples from patients with unrelated diseases and without recent measles or vaccination history. In relation to other diagnostic methods, the IgM ELISA IAL presented sensitivity higher than 97.1%, specificity and precision of 97%, and agreement kappa (k index higher than 0.94 (P Recentes epidemias de sarampo em diferentes países induziram aumento de sorodiagnóstico do sarampo, inclusive em laboratórios de saúde pública brasileiros. Desta forma, desenvolvemos uma técnica de ELISA IgM IAL, utilizando antígenos de vírus do sarampo obtidos de células cultivadas em microcarregadores, com o objetivo de fornecer "kits" de reagentes para diferentes laboratórios. Foi produzida uma partida de reagente para esta técnica imunoenzimática, e os parâmetros diagnósticos foram avaliados em comparação com dados clínicos e de ensaio de referência (ELISA de captura IgM. O reagente foi estudado em um painel positivo tendo 70 soros de pacientes com sarampo e painel negativo com 132 soros de pacientes com doenças não relacionadas e sem história de sarampo recente ou vacinação. A técnica de ELISA IgM IAL demonstrou sensibilidade de 97,1% e 98,6%, especificidades de 97%, e índices kapa de concordância de 0,94 e 0,95 (p < 0,05. O perfil de anticorpo IgM de sarampo da fase aguda foi também semelhante ao do ensaio de referência. Foi proposto ainda um sistema pr

  13. Decontaminating reagents for radioactive systems

    International Nuclear Information System (INIS)

    Seddon, W.A.

    1982-01-01

    A decontaminating reagent composition has been developed comprising EDTA, citric acid, oxalic acid, and formic acid. Formic acid inhibits the decomposition of both EDTA and citric acid, and yields oxalic acid as a result of its own radiolysis. The invention includes the improvement of initially incorporating formic acid in the mixture and maintaining the presence of formic acid by at least one further addition

  14. Targeted Diazotransfer Reagents Enable Selective Modification of Proteins with Azides.

    Science.gov (United States)

    Lohse, Jonas; Swier, Lotteke J Y M; Oudshoorn, Ruben C; Médard, Guillaume; Kuster, Bernhard; Slotboom, Dirk-Jan; Witte, Martin D

    2017-04-19

    In chemical biology, azides are used to chemically manipulate target structures in a bioorthogonal manner for a plethora of applications ranging from target identification to the synthesis of homogeneously modified protein conjugates. While a variety of methods have been established to introduce the azido group into recombinant proteins, a method that directly converts specific amino groups in endogenous proteins is lacking. Here, we report the first biotin-tethered diazotransfer reagent DtBio and demonstrate that it selectively modifies the model proteins streptavidin and avidin and the membrane protein BioY on cell surface. The reagent converts amines in the proximity of the binding pocket to azides and leaves the remaining amino groups in streptavidin untouched. Reagents of this novel class will find use in target identification as well as the selective functionalization and bioorthogonal protection of proteins.

  15. Inactivation of viable Ascaris eggs by reagents during enumeration.

    Science.gov (United States)

    Nelson, K L; Darby, J L

    2001-12-01

    Various reagents commonly used to enumerate viable helminth eggs from wastewater and sludge were evaluated for their potential to inactivate Ascaris eggs under typical laboratory conditions. Two methods were used to enumerate indigenous Ascaris eggs from sludge samples. All steps in the methods were the same except that in method I a phase extraction step with acid-alcohol (35% ethanol in 0.1 N H(2)SO(4)) and diethyl ether was used whereas in method II the extraction step was avoided by pouring the sample through a 38-microm-mesh stainless steel sieve that retained the eggs. The concentration of eggs and their viability were lower in the samples processed by method I than in the samples processed by method II by an average of 48 and 70%, respectively. A second set of experiments was performed using pure solutions of Ascaris suum eggs to elucidate the effect of the individual reagents and relevant combination of reagents on the eggs. The percentages of viable eggs in samples treated with acid-alcohol alone and in combination with diethyl ether or ethyl acetate were 52, 27, and 4%, respectively, whereas in the rest of the samples the viability was about 80%. Neither the acid nor the diethyl ether alone caused any decrease in egg viability. Thus, the observed inactivation was attributed primarily to the 35% ethanol content of the acid-alcohol solution. Inactivation of the eggs was prevented by limiting the direct exposure to the extraction reagents to 30 min and diluting the residual concentration of acid-alcohol in the sample by a factor of 100 before incubation. Also, the viability of the eggs was maintained if the acid-alcohol solution was replaced with an acetoacetic buffer. None of the reagents used for the flotation step of the sample cleaning procedure (ZnSO(4), MgSO(4), and NaCl) or during incubation (0.1 N H(2)SO(4) and 0.5% formalin) inactivated the Ascaris eggs under the conditions studied.

  16. Remotely controlled reagent feed system for mixed waste treatment Tank Farm

    International Nuclear Information System (INIS)

    Dennison, D.K.; Bowers, J.S.; Reed, R.K.

    1995-02-01

    LLNL has developed and installed a large-scale. remotely controlled, reagent feed system for use at its existing aqueous low-level radioactive and mixed waste treatment facility (Tank Farm). LLNL's Tank Farm is used to treat aqueous low-level and mixed wastes prior to vacuum filtration and to remove the hazardous and radioactive components before it is discharged to the City of Livermore Water Reclamation Plant (LWRP) via the sanitary sewer in accordance with established limits. This reagent feed system was installed to improve operational safety and process efficiency by eliminating the need for manual handling of various reagents used in the aqueous waste treatment processes. This was done by installing a delivery system that is controlled either remotely or locally via a programmable logic controller (PLC). The system consists of a pumping station, four sets of piping to each of six 6,800-L (1,800-gal) treatment tanks, air-actuated discharge valves at each tank, a pH/temperature probe at each tank, and the PLC-based control and monitoring system. During operation, the reagents are slowly added to the tanks in a preprogrammed and controlled manner while the pH, temperature, and liquid level are continuously monitored by the PLC. This paper presents the purpose of this reagent feed system, provides background related to LLNL's low-level/mixed waste treatment processes, describes the major system components, outlines system operation, and discusses current status and plans

  17. In situ generation of the Ohira-Bestmann Reagent from stable sulfonyl azide

    DEFF Research Database (Denmark)

    Jepsen, Tue Heesgaard; Kristensen, Jesper Langgaard

    2014-01-01

    We report an improved method for in situ generation of the Ohira-Bestmann reagent. Using the recently reported bench stable imidazole-1-sulfonyl azide as diazotransfer reagent, this new method represents a safe and scalable approach for the transformation of aldehydes into terminal alkynes...

  18. Individualized adjustments to reference phantom internal organ dosimetry—scaling factors given knowledge of patient internal anatomy

    Science.gov (United States)

    Wayson, Michael B.; Bolch, Wesley E.

    2018-04-01

    Various computational tools are currently available that facilitate patient organ dosimetry in diagnostic nuclear medicine, yet they are typically restricted to reporting organ doses to ICRP-defined reference phantoms. The present study, while remaining computational phantom based, provides straightforward tools to adjust reference phantom organ dose for both internal photon and electron sources. A wide variety of monoenergetic specific absorbed fractions were computed using radiation transport simulations for tissue spheres of varying size and separation distance. Scaling methods were then constructed for both photon and electron self-dose and cross-dose, with data validation provided from patient-specific voxel phantom simulations, as well as via comparison to the scaling methodology given in MIRD Pamphlet No. 11. Photon and electron self-dose was found to be dependent on both radiation energy and sphere size. Photon cross-dose was found to be mostly independent of sphere size. Electron cross-dose was found to be dependent on sphere size when the spheres were in close proximity, owing to differences in electron range. The validation studies showed that this dataset was more effective than the MIRD 11 method at predicting patient-specific photon doses for at both high and low energies, but gave similar results at photon energies between 100 keV and 1 MeV. The MIRD 11 method for electron self-dose scaling was accurate for lower energies but began to break down at higher energies. The photon cross-dose scaling methodology developed in this study showed gains in accuracy of up to 9% for actual patient studies, and the electron cross-dose scaling methodology showed gains in accuracy up to 9% as well when only the bremsstrahlung component of the cross-dose was scaled. These dose scaling methods are readily available for incorporation into internal dosimetry software for diagnostic phantom-based organ dosimetry.

  19. 21 CFR 866.3250 - Erysipelothrix rhusiopathiae serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3250... Erysipelothrix rhusiopathiae from cultured isolates derived from clinical specimens. The identification aids in...

  20. 21 CFR 866.3270 - Flavobacterium spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3270.... from cultured isolates derived from clinical specimens. The identification aids in the diagnosis of...

  1. 21 CFR 866.3320 - Histoplasma capsulatum serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3320... capsulatum from clinical specimens or cultured isolates derived from clinical specimens. The identification...

  2. Determination of dose to patient in different teams of TC and assessment with international reference levels

    International Nuclear Information System (INIS)

    Ruiz Morales, C.; Fernandez lara, A. A.; Buades Forner, M. J.; Tobarra Gonzalez, B. M.

    2013-01-01

    The increase in CT studies and the differences observed between the different equipment used in our hospital prompted us to determine the doses to patients in different studies and check the results obtained with the reference values published internationally. (Author)

  3. A community standard format for the representation of protein affinity reagents

    DEFF Research Database (Denmark)

    Gloriam, David Erik Immanuel; Orchard, Sandra; Bertinetti, Daniela

    2010-01-01

    Protein affinity reagents (PARs), most commonly antibodies, are essential reagents for protein characterization in basic research, biotechnology, and diagnostics as well as the fastest growing class of therapeutics. Large numbers of PARs are available commercially; however, their quality is often...... that facilitates easy comparison of their cost and quality. However, in contrast to, for example, nucleotide databases among which data are synchronized between the major data providers, current PAR producers, quality control centers, and commercial companies all use incompatible formats, hindering data exchange....... Here we propose Proteomics Standards Initiative (PSI)-PAR as a global community standard format for the representation and exchange of protein affinity reagent data. The PSI-PAR format is maintained by the Human Proteome Organisation PSI and was developed within the context of Proteome...

  4. 21 CFR 866.3165 - Cryptococcus neoformans serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3165... clinical specimens or from cultured isolates derived from clinical specimens. The identification aids in...

  5. 21 CFR 866.3140 - Corynebacterium spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3140.... from clinical specimens. The identification aids in the diagnosis of disease caused by bacteria...

  6. 21 CFR 866.3110 - Campylobacter fetus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3110 Campylobacter... clinical specimens or cultured isolates derived from clinical specimens. The identification aids in the...

  7. 21 CFR 866.3340 - Klebsiella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3340 Klebsiella... from clinical specimens. The identification aids in the diagnosis of diseases caused by bacteria...

  8. 21 CFR 866.3930 - Vibrio cholerae serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3930 Vibrio... from cultured isolates derived from clinical specimens. The identification aids in the diagnosis of...

  9. 21 CFR 866.3010 - Acinetobacter calcoaceticus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3010... this bacterium from cultured isolates derived from clinical specimens. The identification aids in the...

  10. A Snippet of Grignard Reagent's History

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 18; Issue 8. A Snippet of Grignard Reagent's History. Sujan Singh Dua. Classroom Volume 18 Issue 8 August 2013 pp 777-780. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/018/08/0777-0780. Keywords.

  11. Cross-reactivity of amphetamine analogues with Roche Abuscreen radioimmunoassay reagents

    International Nuclear Information System (INIS)

    Cody, J.T.

    1990-01-01

    Cross-reactivity of amphetamine analogues with the Abuscreen amphetamine radioimmunoassay reagents was determined for both the standard and high specificity antibody systems. Compounds tested included 2-methoxyamphetamine, 4-hydroxymethamphetamine, 2,5-dimethoxyamphetamine (DMA), 4-bromo-2,5-dimethoxyamphetamine (DOB), 4-bromo-2,5-dimethoxy-beta-phenethylamine (BDMPEA), 3,4,5-trimethoxyamphetamine (TMA), 3,4-methylenedioxyamphetamine (MDA), N,N-dimethyl-3,4-methylenedioxyamphetamine and N-hydroxy-3,4-methylenedioxyamphetamine (N-OH MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyethylamphetamine (MDEA), 2,5-dimethoxy-4-ethylamphetamine, 2,5-dimethoxy-4-methylamphetamine (DOM), and 3,4,5-trimethoxyphenethylamine (mescaline). Blank negative reference material was spiked with 1,000 to 100,000 ng/mL of the amphetamine analogue and used as sample in the assays. MDA was the only analogue that showed cross reactivity equal to or greater than that of amphetamine. None of the other analogue compounds demonstrated a positive result at even the highest concentration; however several showed depressed counts at various concentration levels

  12. A reagent-assisted method in SERS detection of methyl salicylate

    Science.gov (United States)

    Li, Yali; Li, Qianwen; Wang, Yanan; Oh, Joohee; Jin, Sila; Park, Yeonju; Zhou, Tieli; Zhao, Bing; Ruan, Weidong; Jung, Young Mee

    2018-04-01

    With the explosive application of methyl salicylate (MS) molecules in food and cosmetics, the further detection of MS molecules becomes particularly important. Here we investigated the detection of MS molecules based on surface-enhanced Raman scattering (SERS) in a novel molecule/assistant/metal system constructed with MS, 4,4‧-(hexafluoroisopropylidene) bis (benzoic acid) and Ag nanoparticles (AgNPs). The minimum detection concentration is 10-4 M. To explore the function of assisted reagent, we also referred another system without assistant molecules. The result demonstrates that SERS signals were not acquired, which proves that the assistant molecules are critical for the capture of MS molecules. Two possible mechanisms of MS/assistant/AgNPs system were speculated through two patterns of hydrogen bonds. The linker molecules acted as the role of the bridge between metallic substrates and target molecules through the molecular recognition. This strategy is very beneficial to the expanding of MS detection techniques and other hydrogen bond based coupling detections with SERS.

  13. Inventory management and reagent supply for automated chemistry.

    Science.gov (United States)

    Kuzniar, E

    1999-08-01

    Developments in automated chemistry have kept pace with developments in HTS such that hundreds of thousands of new compounds can be rapidly synthesized in the belief that the greater the number and diversity of compounds that can be screened, the more successful HTS will be. The increasing use of automation for Multiple Parallel Synthesis (MPS) and the move to automated combinatorial library production is placing an overwhelming burden on the management of reagents. Although automation has improved the efficiency of the processes involved in compound synthesis, the bottleneck has shifted to ordering, collating and preparing reagents for automated chemistry resulting in loss of time, materials and momentum. Major efficiencies have already been made in the area of compound management for high throughput screening. Most of these efficiencies have been achieved with sophisticated library management systems using advanced engineering and data handling for the storage, tracking and retrieval of millions of compounds. The Automation Partnership has already provided many of the top pharmaceutical companies with modular automated storage, preparation and retrieval systems to manage compound libraries for high throughput screening. This article describes how these systems may be implemented to solve the specific problems of inventory management and reagent supply for automated chemistry.

  14. 21 CFR 866.3850 - Trichinella spiralis serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3850... devices that consist of antigens and antisera used in serological tests to identify antibodies to...

  15. 21 CFR 866.3680 - Sporothrix schenckii serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3680... devices that consist of antigens and antisera used in serological tests to identify antibodies to...

  16. 21 CFR 866.3400 - Parainfluenza virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3400 Parainfluenza... that consist of antigens and antisera used in serological tests to identify antibodies to parainfluenza...

  17. 21 CFR 866.3040 - Aspergillus spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3040 Aspergillus... consist of antigens and antisera used in various serological tests to identify antibodies to Aspergillus...

  18. 21 CFR 866.3125 - Citrobacter spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3125 Citrobacter... isolates derived from clinical specimens. The identification aids in the diagnosis of disease caused by...

  19. 21 CFR 866.3740 - Streptococcus spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3740 Streptococcus... derived from clinical specimens. The identification aids in the diagnosis of diseases caused by bacteria...

  20. 21 CFR 866.3065 - Bordetella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3065 Bordetella... serological tests to identify Bordetella spp. from cultured isolates or directly from clinical specimens. The...

  1. Internal Dose Conversion Coefficients of Domestic Reference Animal and Plants for Dose Assessment of Non-human Species

    International Nuclear Information System (INIS)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Choi, Yong Ho

    2009-01-01

    Traditionally, radiation protection has been focused on a radiation exposure of human beings. In the international radiation protection community, one of the recent key issues is to establish the methodology for assessing the radiological impact of an ionizing radiation on non-human species for an environmental protection. To assess the radiological impact to non-human species dose conversion coefficients are essential. This paper describes the methodology to calculate the internal dose conversion coefficient for non-human species and presents calculated internal dose conversion coefficients of 25 radionuclides for 8 domestic reference animal and plants

  2. 21 CFR 866.3145 - Coxsackievirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3145... fluorescent dye that are used to identify coxsackievirus from clinical specimens or from tissue culture isolates derived from clinical specimens. The identification aids in the diagnosis of coxsackievirus...

  3. USE OF FENTON'S REAGENT AS A DISINFECTANT

    Science.gov (United States)

    Combined sewage samples obtained from a wastewater treatment facility were disinfected by the Fenton's Reagent of several different compositions. The pre-settled samples contained both suspended solids (SS) and dissolved organic carbon (DOC) at concentrations of 28 and 290 mg/L,...

  4. Selective Flotation of Calcite from Fluorite: A Novel Reagent Schedule

    Directory of Open Access Journals (Sweden)

    Zhiyong Gao

    2016-10-01

    Full Text Available Fluorite is an important strategic mineral. In general, fluorite ores will contain a certain amount of calcite gangue mineral. Thus, they need to be separated from each other. For an economic separation, a reverse flotation process is used to float calcite gangue from fluorite. However, little information on the separation is available. In this study, a novel reagent schedule using citric acid (CA as the depressant, sodium fluoride (NaF as the regulator and sulfoleic acid (SOA as the collector, was developed to separate calcite from fluorite. The results demonstrated a high selectivity for the flotation of calcite from fluorite using this new reagent schedule. The best selective separation for a single mineral and mixed binary minerals was obtained when 200 mg/L of NaF, 50 mg/L of CA, and 6 mg/L of SOA were used at pH 9. In addition, a batch flotation experiment was carried out using a run-of-mine feed material. Selective separation was achieved with 85.18% calcite removal while only 11.2% of fluorite was lost. An attempt was made to understand the effect of the new reagent schedule on the flotation of calcite. The results from both microflotation and bench scale flotation demonstrated a great potential for industrial application using this novel reagent schedule to upgrade fluorite ore.

  5. Genotoxicity assessment of membrane concentrates of landfill leachate treated with Fenton reagent and UV-Fenton reagent using human hepatoma cell line.

    Science.gov (United States)

    Wang, Guifang; Lu, Gang; Yin, Pinghe; Zhao, Ling; Yu, Qiming Jimmy

    2016-04-15

    Membrane concentrates of landfill leachates contain organic and inorganic contaminants that could be highly toxic and carcinogenic. In this paper, the genotoxicity of membrane concentrates before and after Fenton and UV-Fenton reagent was assessed. The cytotoxicity and genotoxicity was determined by using the methods of methyltetrazolium (MTT), cytokinesis-block micronucleus (CBMN) and comet assay in human hepatoma cells. MTT assay showed a cytotoxicity of 75% after 24h of exposure to the highest tested concentration of untreated concentrates, and no cytotoxocity for UV-Fenton and Fenton treated concentrates. Both CBMN and comet assays showed increased levels of genotoxicity in cells exposed to untreated concentrates, compared to those occurred in cells exposed to UV-Fenton and Fenton reagent treated concentrates. There was no significant difference between negative control and UV-Fenton treated concentrates for micronucleus and comet assay parameters. UV-Fenton and Fenton treatment, especially the former, were effective methods for degradation of bisphenol A and nonylphenol in concentrates. These findings showed UV-Fenton and Fenton reaction were effective methods for treatment of such complex concentrates, UV-Fenton reagent provided toxicological safety of the treated effluent, and the genotoxicity assays were found to be feasible tools for assessment of toxicity risks of complex concentrates. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. POLYNUCLEAR AROMATIC HYDROCARBON (PAH) RELEASE FROM SOIL DURING TREATMENT WITH FENTON'S REAGENT

    Science.gov (United States)

    Fenton's Reagent was used to treat soil from a wood-treating site in southeastern Ohio which had been contaminated with creosote. Slurries, consisting of 10 µg of contaminated soil and 30 mL water were treated with 40 mL of Fenton's Reagent (1:1 of 30% H2O2 ...

  7. 21 CFR 866.3870 - Trypanosoma spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3870 Trypanosoma... consist of antigens and antisera used in serological tests to identify antibodies to Trypanosoma spp. in...

  8. 21 CFR 866.3630 - Serratia spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3630 Serratia spp... antigens and antisera used in serological tests to identify Serratia spp. from cultured isolates. The...

  9. 21 CFR 866.3660 - Shigella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3660 Shigella spp...), used in serological tests to identify Shigella spp. from cultured isolates. The identification aids in...

  10. 21 CFR 866.3330 - Influenza virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3330 Influenza... consist of antigens and antisera used in serological tests to identify antibodies to influenza in serum...

  11. 21 CFR 866.3035 - Arizona spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3035 Arizona spp... antisera and antigens used to identify Arizona spp. in cultured isolates derived from clinical specimens...

  12. 21 CFR 866.3380 - Mumps virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3380 Mumps virus... serological tests to identify mumps viruses from tissue culture isolates derived from clinical specimens. The...

  13. Refer to AP1000 for discussing the betterment of seismic design of internal nuclear power plant

    International Nuclear Information System (INIS)

    Gong Zhenbang; Zhang Renyan

    2014-01-01

    As a reference technique of AP1000, This paper discussed the betterment of seismic design of nuclear power plant in three ways. (1) Establish design criteria and guidelines for protection from seismic interaction; (2) Nuclear power plant seismic design of eliminating or weaken operation-basis earthquake; (3) Develop the seismic margin analysis (SMA) of the nuclear power plant. These three aspect are frontier technology in internal seismic design of internal nuclear power plant, and also these three technology are related intimately. (authors)

  14. Copper-Catalyzed Oxy-Alkynylation of Diazo Compounds with Hypervalent Iodine Reagents.

    Science.gov (United States)

    Hari, Durga Prasad; Waser, Jerome

    2016-02-24

    Alkynes have found widespread applications in synthetic chemistry, biology, and materials sciences. In recent years, methods based on electrophilic alkynylation with hypervalent iodine reagents have made acetylene synthesis more flexible and efficient, but they lead to the formation of one equivalent of an iodoarene as side-product. Herein, a more efficient strategy involving a copper-catalyzed oxy-alkynylation of diazo compounds with ethynylbenziodoxol(on)e (EBX) reagents is described, which proceeds with generation of nitrogen gas as the only waste. This reaction is remarkable for its broad scope in both EBX reagents and diazo compounds. In addition, vinyl diazo compounds gave enynes selectively as single geometric isomers. The functional groups introduced during the transformation served as easy handles to access useful building blocks for synthetic and medicinal chemistry.

  15. Sperm cell purification from mock forensic swabs using SOMAmer™ affinity reagents.

    Science.gov (United States)

    Katilius, Evaldas; Carmel, Andrew B; Koss, Heidi; O'Connell, Dan; Smith, Breanna C; Sanders, Glenn M; LaBerge, Greggory S

    2018-03-27

    We have demonstrated a proof of concept with affinity-based purification of sperm cells from mock forensic samples using SOMAmer™ reagents, DNA-based affinity reagents developed by SomaLogic, Inc. SOMAmer reagents were selected in vitro using whole-cell SELEX to bind specifically with intact, detergent-treated sperm cells. Successful separation of sperm from epithelial cells and their debris was demonstrated using buccal swabs with added semen. Primarily male DNA profiles were generated from sperm cells eluted from the types of cotton swabs typically used for rape kit evidence collection. The quality of sperm DNA isolated from samples purified using SOMAmers is comparable to existing commercially available differential extraction-based methods at higher sperm concentrations. This purification method is simple, offers relatively rapid (forensic casework. Copyright © 2018. Published by Elsevier B.V.

  16. Reagent-Free Quantification of Aqueous Free Chlorine via Electrical Readout of Colorimetrically Functionalized Pencil Lines.

    Science.gov (United States)

    Mohtasebi, Amirmasoud; Broomfield, Andrew D; Chowdhury, Tanzina; Selvaganapathy, P Ravi; Kruse, Peter

    2017-06-21

    Colorimetric methods are commonly used to quantify free chlorine in drinking water. However, these methods are not suitable for reagent-free, continuous, and autonomous applications. Here, we demonstrate how functionalization of a pencil-drawn film with phenyl-capped aniline tetramer (PCAT) can be used for quantitative electric readout of free chlorine concentrations. The functionalized film can be implemented in a simple fluidic device for continuous sensing of aqueous free chlorine concentrations. The sensor is selective to free chlorine and can undergo a reagent-free reset for further measurements. Our sensor is superior to electrochemical methods in that it does not require a reference electrode. It is capable of quantification of free chlorine in the range of 0.1-12 ppm with higher precision than colorimetric (absorptivity) methods. The interactions of PCAT with the pencil-drawn film upon exposure to hypochlorite were characterized spectroscopically. A previously reported detection mechanism relied on the measurement of a baseline shift to quantify free chlorine concentrations. The new method demonstrated here measures initial spike size upon exposure to free chlorine. It relies on a fast charge built up on the sensor film due to intermittent PCAT salt formation. It has the advantage of being significantly faster than the measurement of baseline shift, but it cannot be used to detect gradual changes in free chlorine concentration without the use of frequent reset pulses. The stability of PCAT was examined in the presence of free chlorine as a function of pH. While most ions commonly present in drinking water do not interfere with the free chlorine detection, other oxidants may contribute to the signal. Our sensor is easy to fabricate and robust, operates reagent-free, and has very low power requirements and is thus suitable for remote deployment.

  17. A new achiral reagent for the incorporation of multiple amino groups into oligonucleotides

    DEFF Research Database (Denmark)

    Behrens, Carsten; Petersen, Kenneth H.; Egholm, Michael

    1995-01-01

    The synthesis of a new functionalized achiral linker reagent (10) for the incorporation of multiple primary amino groups into oligonucleotides is described. The linker reagent is compatible with conventional DNA-synthesis following the phosphoramidite methodology, and the linker can be incorporated...

  18. Internal and external dose conversion coefficient for domestic reference animals and plant

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Park, Du Won; Choi, Young Ho

    2009-07-15

    This report presents the internal and external dose conversion coefficients for domestic reference animals and plant, which are essential to assess the radiological impact of an environmental radiation on non-human species. To calculate the dose conversion coefficients, a uniform isotropic model and a Monte Carlo method for a photon transport simulation in environmental media with different densities have been applied for aquatic and terrestrial animals, respectively. In the modeling all the target animals are defined as a simple 3D elliptical shape. To specify the external radiation source it is assumed that aquatic animals are fully immersed in infinite and uniformly contaminated water, and the on-soil animals are living on the surface of a horizontally infinite soil source, and the in-soil organisms are living at the center of a horizontally infinite and uniformly contaminated soil to a depth of 50cm. A set of internal and external dose conversion coefficients for 8 Korean reference animals and plant (rat, roe-deer, frog, snake, Chinese minnow, bee, earthworm, and pine tree) are presented for 25 radionuclides ({sup 3}H, {sup 7}Be, {sup 14}C, {sup 40}K, {sup 51}Cr, {sup 54}Mn, {sup 59}Fe, {sup 58}Co, {sup 60}Co, {sup 65}Zn, {sup 90}Sr, {sup 95}Zr, {sup 95}Nb, {sup 99}Tc, {sup 106}Ru, {sup 129}I, {sup 131}I, {sup 136}Cs, {sup 137}Cs, {sup 140}Ba, {sup 140}La, {sup 144}Ce, {sup 238}U, {sup 239}Pu, and {sup 240}Pu)

  19. Organophosphorus reagents in actinide separations: Unique tools for production, cleanup and disposal

    International Nuclear Information System (INIS)

    Nash, K. L.

    2000-01-01

    Interactions of actinide ions with phosphate and organophosphorus reagents have figured prominently in nuclear science and technology, particularly in the hydrometallurgical processing of irradiated nuclear fuel. Actinide interactions with phosphorus-containing species impact all aspects from the stability of naturally occurring actinides in phosphate mineral phases through the application of the bismuth phosphate and PUREX processes for large-scale production of transuranic elements to the development of analytical separation and environment restoration processes based on new organophosphorus reagents. In this report, an overview of the unique role of organophosphorus compounds in actinide production, disposal, and environment restoration is presented. The broad utility of these reagents and their unique chemical properties is emphasized

  20. The adsorption of chelating reagents on oxide minerals

    International Nuclear Information System (INIS)

    Bryson, M.A.W.

    1984-06-01

    This work constitutes a fundamental study of the interaction between chelating reagents and oxide minerals. The adsorption mechanisms have been elucidated for most of the systems generated by the oxides of copper(II) or iron(III) and chelating reagents octyl hydroxamate, N-phenylbenzohydroxamate, salicylaldoxime, 5-nitro-salicylaldoxime or 8-hydroxyquinoline. In order to better understand the adsorption process associated with copper(II) oxide, the oxide was recrystallized to produce a coarser material with a more uniform surface. This allowed the oxide surface to be viewed under the scanning electron microscope. A detailed investigation of the effect of the system variables; pH, conditioning period, concentration, temperature, surface area and dispersing reagent on the rate of precipitation of the copper chelate species of general form, Cu(chel) 2 , was made. In addition the chemical nature of the adsorbed species and the structural form of the precipitates were determined with the aid of infra-red spectroscopy and the scanning electron microscope. On the basis of these results a model has been formulated for the adsorption processes. The precipitation process was examined in more detail by the study of the adsorption of chelate on copper metal. Contact angle measurements of air bubbles on copper metal conditioned with chelate were related to the adsorption results in an attempt to isolate the optimum conditions for flotation of oxide minerals

  1. Application of flotational reagents obtained from coke-industry byproducts

    Energy Technology Data Exchange (ETDEWEB)

    N.I. Nikitin; I.N. Nikitin; N.I. Toporkova [Khar' kov Polytechnic Institute (Ukraine)

    2007-06-15

    Today, the operational efficiency of coal-preparation shops at coke plants largely depends on the flotation process, since flotation is the basic method of regenerating the slurry water in the water-slurry systems and the basic enrichment process for small-grain coal slurries. At The Coal-Chemistry Institute, attempts have been made to address the growing demand for readily available and relatively inexpensive flotational reagents. In particular, a list of promising coke-industry byproducts for use as flotational reagents has been compiled, and the possibility of reducing their toxicity has been established. In addition, various industrial byproducts and wastes have been investigated in terms of flotational activity.

  2. [Comparative measurement of urine specific gravity: reagent strips, refractometry and hydrometry].

    Science.gov (United States)

    Costa, Christian Elías; Bettendorff, Carolina; Bupo, Sol; Ayuso, Sandra; Vallejo, Graciela

    2010-06-01

    The urine specific gravity is commonly used in clinical practice to measure the renal concentration/dilution ability. Measurement can be performed by three methods: hydrometry, refractometry and reagent strips. To assess the accuracy of different methods to measure urine specific gravity. We analyzed 156 consecutive urine samples of pediatric patients during April and May 2007. Urine specific gravity was measured by hydrometry (UD), refractometry (RE) and reagent strips (TR), simultaneously. Urine osmolarity was considered as the gold standard and was measured by freezing point depression. Correlation between different methods was calculated by simple linear regression. A positive and acceptable correlation was found with osmolarity for the RE as for the UD (r= 0.81 and r= 0.86, respectively). The reagent strips presented low correlation (r= 0.46). Also, we found good correlation between measurements obtained by UD and RE (r= 0.89). Measurements obtained by TR, however, had bad correlation when compared to UD (r= 0.46). Higher values of specific gravity were observed when measured with RE with respect to UD. Reagent strips are not reliable for measuring urine specific gravity and should not be used as an usual test. However, hydrometry and refractometry are acceptable alternatives for measuring urine specific gravity, as long as the same method is used for follow-up.

  3. Reagents Activity in a Copper Droplets / Post-Processing Slag Suspension

    OpenAIRE

    Wołczyński W.; Karwan-Baczewska J.; Najman K.; Bydałek A.W.

    2016-01-01

    The suspension of the copper droplets in the post-processing slag taken directly from the KGHM-Polska Miedź S.A. Factory (from the direct-to-blister technology as performed in the flash furnace) was subjected to the special treatment with the use of the one of the typical industrial reagent and with the complex reagent newly patented by the authors. This treatment was performed in the BOLMET S.A. Company in the semi-industrial conditions. The result of the CaCO3, and Na2CO3 chemicals influenc...

  4. Risk-based Strategy to Determine Testing Requirement for the Removal of Residual Process Reagents as Process-related Impurities in Bioprocesses.

    Science.gov (United States)

    Qiu, Jinshu; Li, Kim; Miller, Karen; Raghani, Anil

    2015-01-01

    The purpose of this article is to recommend a risk-based strategy for determining clearance testing requirements of the process reagents used in manufacturing biopharmaceutical products. The strategy takes account of four risk factors. Firstly, the process reagents are classified into two categories according to their safety profile and history of use: generally recognized as safe (GRAS) and potential safety concern (PSC) reagents. The clearance testing of GRAS reagents can be eliminated because of their safe use historically and process capability to remove these reagents. An estimated safety margin (Se) value, a ratio of the exposure limit to the estimated maximum reagent amount, is then used to evaluate the necessity for testing the PSC reagents at an early development stage. The Se value is calculated from two risk factors, the starting PSC reagent amount per maximum product dose (Me), and the exposure limit (Le). A worst-case scenario is assumed to estimate the Me value, that is common. The PSC reagent of interest is co-purified with the product and no clearance occurs throughout the entire purification process. No clearance testing is required for this PSC reagent if its Se value is ≥1; otherwise clearance testing is needed. Finally, the point of the process reagent introduction to the process is also considered in determining the necessity of the clearance testing for process reagents. How to use the measured safety margin as a criterion for determining PSC reagent testing at process characterization, process validation, and commercial production stages are also described. A large number of process reagents are used in the biopharmaceutical manufacturing to control the process performance. Clearance testing for all of the process reagents will be an enormous analytical task. In this article, a risk-based strategy is described to eliminate unnecessary clearance testing for majority of the process reagents using four risk factors. The risk factors included

  5. Tetrameric DABCO™-Bromine: an Efficient and Versatile Reagent ...

    African Journals Online (AJOL)

    NJD

    Reagent for Bromination of Various Organic Compounds. Majid M. Heravi,a* ... aDepartment of Chemistry, School of Sciences, Azzahra University, Vanak, Tehran, Iran. bChemistry ... Synthesis of "-bromo ketones and nitriles has also been ...

  6. Effect of some colloid surfactants on spectrophotometric characteristics of metal chelates with chromophore organic reagents

    International Nuclear Information System (INIS)

    Chernova, R.K.

    1977-01-01

    Theoretical regularities and prospects of using surface active substances (SAS) in spectrophotometric determination of metal ions (including ions of rare-earth elements, transition metals, Be(3)) with chromophore chelating reagents were investigated. The chromophore reagents investigated were pyrocatechol violet, phenolcarboxylic acids of the triarylmethane series, fluorones, phthalexones and azo-compounds. As SAS certain long-chain quaternary ammonium and pyridinium salts (LQAS) were employed. From the results reported it follows that the introduction of LQAS in the system of Mesup(n+)-chromophore reagent is a rather effective method of enhancing the contrast rendition and, in some cases, the sensitivity and selectivity of the reagents. Explanations are suggested as to the factors which cause the changes observed in the contrast of the reactions in the presence of SAS; the underlying phenomena are the ligand-ligand interactions between the organic reagents and SAS and solubilization processes of the reaction products by the micelles of SAS

  7. 21 CFR 866.3240 - Equine encephalomyelitis virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents... these viruses. Equine encephalomyelitis viruses are transmitted to humans by the bite of insects, such...

  8. 21 CFR 866.3480 - Respiratory syncytial virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3480... respiratory syncytial viruses from clinical specimens or from tissue culture isolates derived from clinical...

  9. Kalman filtering applied to a reagent feed system

    International Nuclear Information System (INIS)

    Griffin, C.D.; Croson, D.V.; Feeley, J.J.

    1988-01-01

    Using a Kalman filter solves a troublesome measurement noise problem and, at the same time, improves nuclear safety by detecting leaks to the process' feed tanks. To demonstrate how this technology of optimal estimation can be exploited, this article presents a systematic plan and example of how a Kalman filter was proven in industrial use on a reagent analyzer. A process to recycle uranium from spent fuel elements uses a reagent stream containing boron to dissolve the fuel. The boron is the neutron poison that prevents a nuclear chain reaction during the uranium dissolution. The purpose of the Kalman filter for this system is to reduce the uncertainty in the boron concentration measurement. The filter also provides incipient fault detection by estimating the unmeasured state of any unpoisoned solution, which would dilute the boron solution, entering the feed vessel

  10. Estimation of 239Pu in urine, influence of Sulkowich reagent

    International Nuclear Information System (INIS)

    Kalaiselvan, S.; Prasad, M.V.R.; Jeevanram, R.K.

    1988-01-01

    Plutonium is known to be co-precipitated with Sulkowich reagent as calcium ammonium oxalate. In adopting this technique for bio-assay of plutonium, its accuracy depends on the self-absorption of the resulting precipitate in each urine sample. Pu recovery experiments were carried out with varying concentration of Ca and Mg, using different volumes of Sulkowich reagent. When the sample volume is 500 ml, Pu in urine can be estimated with an accuracy and precision of 74.38%+-7.4%, with a detection limit of 0.06 Bq (1.6 pCi) per dm 3 . (author) 3 refs.; 2 figs.; 2 tabs

  11. Effects of sh-reagents on rat hepatic aldehyde dehydrogenase activity

    Energy Technology Data Exchange (ETDEWEB)

    Konoplitskaya, K.L.; Kuz' mina, G.I.; Grigor' yeva, M.V.; Poznyakova, T.N.

    The liver serves as the primary organ for the oxidation of ingested ethanol via a pathway involving alcohol- and aldehyde dehydrogenase. In view of the problem of alcoholism, three enzymes are of particular interest in understanding the biochemical mechanism that may be involved in alcohol addiction and in the formulation of therapeutic approaches. While alcohol dehydrogenase has been studied in considerable detail, current attention is centered on aldehyde dehydrogenase. A comparative analysis of the effects of a series of SH-active reagents - tetraethylthiuram disulfide (TETD), 5,5-dithiobisnitrobenzoic acid (DTNB), p-chloromercurybenzoate (PCMB), and N-ethylmaleimide (NEM) - were tested for their effects on the activity of aldehyde dehydrogenase of the hepatic mitochondrial (isozymes I and II) and microsomal (isozyme II) fractions of outbred albino rats. DTNB was found to be inhibited by 100 and 50% mitochondrial isozymes I and II, respectively, and by 20%, the microsomal enzyme under the conditions employed. DTNB and NEM inhibited by 30 and 50% isozymes I and II of the mitochondria, but had no effect on the microsomal isozyme. 24 references, 3 figures.

  12. Facile synthesis of aliphatic isothiocyanates and thioureas on solid phase using peptide coupling reagents

    DEFF Research Database (Denmark)

    Boas, Ulrik; Andersen, Heidi Gertz; Christensen, Jørn B.

    2004-01-01

    Peptide coupling reagents can be used as versatile reagents for the formation of aliphatic isothiocyanates and thioureas on solid phase from the corresponding solid-phase anchored aliphatic primary amines. The formation of the thioureas is fast and highly chemoselective, and proceeds via formatio...

  13. 21 CFR 866.3940 - West Nile virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3940 West Nile... detection aids in the clinical laboratory diagnosis of viral meningitis/encephalitis caused by West Nile...

  14. Radioimmunoassay reagent and its use in a radioimmunoassay

    International Nuclear Information System (INIS)

    Polito, A.J.; Knight, W.S.

    1977-01-01

    A radioimmunoassay to detect or determine a steroid of the cortisone and aldosterone group has been developed. The invention particularly concerns a steroid derivative containing imidazole group which is radioactively labelled. The invented reagents are labelled with iodine 125. (VJ) [de

  15. Fenton's Reagent. Innovative Technology Summary Report

    International Nuclear Information System (INIS)

    None

    1999-01-01

    The Fenton's Reagent DNAPL treatment process is an in situ oxidation method to destroy DNAPLs in groundwater. Residual industrial solvents, primarily Dense Non-Aqueous Phase Liquids (DNAPLs), are currently the most significant barrier to successful completion of most large groundwater and soil cleanup efforts. DNAPL pools and residues slowly dissolve into surrounding groundwater to create large plumes of organic solvent contamination with concentration levels far above regulatory limits

  16. Reagents and fractions impact on sulphide ore heap bioleaching at Smolnik mine

    Science.gov (United States)

    Oros, L. M.; Zavada, J.

    2017-10-01

    Mine Smolnik is one of the oldest sulphide ore mines in Europe and it is also an important part of bioleaching development. This paper follows previous attempts to extract residual metals from nearby heaps via variations in bioleaching reagents with regard to recent findings and needs in the related industry. Furthermore, economic and process relations between reagents and chosen heap fractions were also investigated in this case study.

  17. Oxidative Degradation of Phenol containing Wastewater using Fenton Reagent, Permanganate and Ultraviolet Radiation

    International Nuclear Information System (INIS)

    Abd El-Rahman, N.M.; Talaat, H.A.; Sorour, M.H.

    1999-01-01

    Phenol containing wastewaters are generated by numerous industrial units including integrated steel mills, textile mills, plastic production, etc. The present work is targeted to explore the viable oxidation techniques for degradation of phenolic wastewater. Three modes of treatment have been adopted in this study, namely, sole oxidant mode using Fenton reagent or permanganate, UV-assisted oxidation and two consequent chemical oxidation steps. Results indicated the superiority of fenton reagent over KMnO 4 oxidation in the sole oxidant mode. On the other hand, UV-assisted KMnO 4 oxidation enables almost complete COD reduction. Dual chemical oxidation mode employing KMnO 4 oxidation followed by Fenton reagent is also an efficient oxidative degradation system

  18. A new method for quasi-reagent-free biomonitoring of mercury in human urine.

    Science.gov (United States)

    Schlathauer, Maria; Reitsam, Verena; Schierl, Rudolf; Leopold, Kerstin

    2017-05-01

    A novel analytical method for sampling and extraction of mercury (Hg) from human urine is presented in this work. The method is based on selective accumulation and separation of Hg from fresh urine sample onto active nanogold-coated silica material by highly efficient solid-phase extraction. After thermal desorption of Hg from the extractant, detection is performed by atomic fluorescence spectrometry (AFS). The feasibility and validity of the optimized, quasi-reagent-free approach was confirmed by recovery experiments in spiked real urine (recovery rate 96.13 ± 5.34%) and by comparison of found Hg concentrations in real urine samples - originating from occupationally exposed persons - with values obtained from reference methods cold vapor - atomic absorption spectrometry (CVAAS) and cold vapor - atomic fluorescence spectrometry (CV-AFS). A very good agreement of the found values reveals the validity of the proposed approach. The limit of detection (LOD) was found to be as low as 0.004 μg Hg L -1 and a high reproducibility with a relative standard deviations ≤4.2% (n = 6) is given. Moreover, storage of the samples for up to one week at an ambient temperature of 30 °C reveals no analyte losses or contamination. In conclusion, the proposed method enables easy-to-handle on-site extraction of total Hg from human urine ensuring at the same time reagent-free sample stabilization, providing quick and safe sampling, which can be performed by untrained persons. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Pentobarbital quantitation using EMIT serum barbiturate assay reagents: application to monitoring of high-dose pentobarbital therapy.

    Science.gov (United States)

    Pape, B E; Cary, P L; Clay, L C; Godolphin, W

    1983-01-01

    Pentobarbital serum concentrations associated with a high-dose therapeutic regimen were determined using EMIT immunoassay reagents. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of 5.0% and a between-assay coefficient of variation of 10%. Regression analysis of 44 serum samples analyzed by this technique (y) and a reference procedure (x) were y = 0.98x + 3.6 (r = 0.98; x = ultraviolet spectroscopy) and y = 1.04x + 2.4 (r = 0.96; x = high-performance liquid chromatography). Clinical evaluation of the results indicates the immunoassay is sufficiently sensitive and selective for pentobarbital to allow accurate quantitation within the therapeutic range associated with high-dose therapy.

  20. Mechanism of red mud combined with Fenton's reagent in sewage sludge conditioning.

    Science.gov (United States)

    Zhang, Hao; Yang, Jiakuan; Yu, Wenbo; Luo, Sen; Peng, Li; Shen, Xingxing; Shi, Yafei; Zhang, Shinan; Song, Jian; Ye, Nan; Li, Ye; Yang, Changzhu; Liang, Sha

    2014-08-01

    Red mud was evaluated as an alternative skeleton builder combined with Fenton's reagent in sewage sludge conditioning. The results show that red mud combined with Fenton's reagent showed good conditioning capability with the pH of the filtrate close to neutrality, indicating that red mud acted as a neutralizer as well as a skeleton builder when jointly used with Fenton's reagent. Through response surface methodology (RSM), the optimal dosages of Fe(2+), H2O2 and red mud were proposed as 31.9, 33.7 and 275.1 mg/g DS (dry solids), respectively. The mechanism of the composite conditioner could be illuminated as follows: (1) extracellular polymeric substances (EPS), including loosely bound EPS and tightly bound EPS, were degraded into dissolved organics, e.g., proteins and polysaccharides; (2) bound water was released and converted into free water due to the degradation of EPS; and (3) morphology of the conditioned sludge exhibited a porous structure in contrast with the compact structure of raw sludge, and the addition of red mud formed new mineral phases and a rigid lattice structure in sludge, allowing the outflow of free water. Thus, sludge dewatering performance was effectively improved. The economic assessment for a wastewater treatment plant of 370,000 equivalent inhabitants confirms that using red mud conditioning, combined with Fenton's reagent, leads to a saving of approximately 411,000 USD/y or 50.8 USD/t DS comparing with using lime and ordinary Portland cement combined with Fenton's reagent, and approximately 612,000 USD/y or 75.5 USD/t DS comparing with the traditional treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Alkylation of pyridines at their 4-positions with styrenes plus yttrium reagent or benzyl Grignard reagents.

    Science.gov (United States)

    Mizumori, Tomoya; Hata, Takeshi; Urabe, Hirokazu

    2015-01-02

    A new regioselective alkylation of pyridines at their 4-position was achieved with styrenes in the presence of yttrium trichloride, BuLi, and diisobutylaluminium hydride (DIBAL-H) in THF. Alternatively, similar products were more simply prepared from pyridines and benzyl Grignard reagents. These reactions are not only a useful preparation of 4-substituted pyridines but are also complementary to other relevant reactions usually giving 2-substituted pyridines. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. 21 CFR 866.3085 - Brucella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3085 Brucella spp... from clinical specimens or to identify antibodies to Brucella spp. in serum. Additionally, some of... to identify Brucella spp. directly from clinical specimens or cultured isolates derived from clinical...

  3. 21 CFR 866.3235 - Epstein-Barr virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3235 Epstein-Barr... consist of antigens and antisera used in serological tests to identify antibodies to Epstein-Barr virus in...

  4. Development of reagents for radioimmunoassay of: triiodothyronine, thyroxine and thyrotrophin

    International Nuclear Information System (INIS)

    Delgado S, B.; Lavalley E, C.; Ruiz J, A.; Garcia F, C.; Zamorano A, F.

    1991-12-01

    The radioimmunoassay (RIA) of thyroid hormones it is the but it frequents of all the studies carried out by RIA in the laboratories of Nuclear Medicine, these essays are carried out with imported reagents. In the ININ the reagents and the necessary methodology have been developed for the triiodothyronine (T3), thyroxine (T4) and thyrotrophin (TSH). The good titles of the antibodies (Ac) primary for each hormone were of 1:4,000; 1:750 and 1:1,500. The used separation system was of double Ac with PEG to 10%, with titles of 1:10 for the second Ac of lamb. The specific activity for 125-I-T3 and 125-I-T4 oscillate between 850 at 900 μCi / μ g: being this of 90 μ Ci /μg for TSH. To the first two hormones they were added 1-8 aniline naftalen sulfonic acid (ANS) to concentrations of 3 and 2 mg/ml respectively. As buffer for T3 and T4 it was used Tris-HCl pH 8.6 and PBS with normal serum of rabbit (SNC) for TSH. The standards got ready in buffer or free serum of thyroid hormones. The slope of the standard curves varied between -2.3 to -2.7 and the variation intra and inter assay among 4 to 10%. It is had at the moment in the ININ with standardized reagents for the RIA of T3, T4 and TSH, it is hoped to carry out tests in other laboratories and to establish the conditions of stability more appropriate to begin the preparation of pilot reagents. (Author)

  5. Stability of Loop-Mediated Isothermal Amplification (LAMP) Reagents and its Amplification Efficiency on Crude Trypanosome DNA Templates

    OpenAIRE

    Thekisoe, Oriel M. M; Bazie, Raoul S. B; Coronel-Servian, Andrea M; Sugimoto, Chihiro; Kawazu, Shin-ichiro; Inoue, Noboru

    2009-01-01

    This study evaluated the stability of LAMP reagents when stored at 25C and 37C, and also assessed its detection efficiency on different DNA template preparations. Accordingly, LAMP using reagents stored at 25C and 37C amplified DNA of in vitro cultured T. b. brucei (GUTat 3.1) from day 1 to day 15 of reagent storage. There were no significant differences (P>0.05) in detection sensitivity of LAMP among the reagents stored at 25C, 37C and –20C (recommended storage temperature). LAMP usin...

  6. Interaction of Celestine Concentrate and Reagent Grade SrSO4 with Oxalate Solutions

    Directory of Open Access Journals (Sweden)

    Abdullah Obut

    2012-12-01

    Full Text Available The interaction of reagent grade strontium sulphate and celestine concentrate with aqueous solutions of oxalic acid, sodiumoxalate and ammonium oxalate for the production of strontium carbonate were investigated for different oxalate compound:SrSO4 moleratios and reaction times using x-ray diffraction analysis and dissolution tests. Under the same experimental conditions, it was foundthat aqueous oxalic acid and sodium oxalate solutions had no or little effect on reagent grade strontium sulphate or celestineconcentrate, but aqueous ammonium oxalate solution converted them into strontium oxalate hydrate. Strontium carbonate was obtainedat conversion ratios of 74.7% for the celestine concentrate and 84.6 % for the reagent grade strontium sulphate by the decompositionof the obtained strontium oxalate hydrate at 600 °C under air atmosphere.

  7. Towards better description of solar activity variation in the International Reference Ionosphere topside ion composition model

    Czech Academy of Sciences Publication Activity Database

    Truhlík, Vladimír; Bilitza, D.; Třísková, Ludmila

    2015-01-01

    Roč. 55, č. 8 (2015), s. 2099-2105 ISSN 0273-1177 R&D Projects: GA MŠk(CZ) LH11123 Institutional support: RVO:68378289 Keywords : ion composition * topside ionosphere * solar activity * empirical model * International Reference Ionosphere Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.409, year: 2015 http://www.sciencedirect.com/science/article/pii/S027311771400489X

  8. [Reference citation].

    Science.gov (United States)

    Brkić, Silvija

    2013-01-01

    Scientific and professional papers represent the information basis for scientific research and professional work. References important for the paper should be cited within the text, and listed at the end of the paper. This paper deals with different styles of reference citation. Special emphasis was placed on the Vancouver Style for reference citation in biomedical journals established by the International Committee of Medical Journal Editors. It includes original samples for citing various types of articles, both printed and electronic, as well as recommendations related to reference citation in accordance with the methodology and ethics of scientific research and guidelines for preparing manuscripts for publication.

  9. Comparison of vacuum metal deposition and 1,2-indandione/ninhydrin reagent method for the development of fingerprints on renminbi

    Directory of Open Access Journals (Sweden)

    Cong Wang

    2017-01-01

    Full Text Available It is extremely difficult to develop fingerprints from the surface of currency. There are studies reporting that the high vacuum metal deposition (VMD method can be used to detect fingerprints on certain types of currency notes. Both VMD and 1,2-indandione/ninhydrin techniques are employed to visualize latent fingermarks on porous surfaces, such as paper. The current study explores whether the VMD method or 1,2-indandione/ninhydrin reagent method is more effective in the development of fingerprints on renminbi (RMB. Uncirculated, circulated, and water-exposed RMB was utilized in this study, along with five donors who ranged in their age and potential to leave fingermarks. Samples were aged for a determined period (for uncirculated and circulated RMB, times were 1, 3, 5, 10, and 35 days; for water-exposed RMB, exposure time was 1 day and then treated with VMD and 1,2-indandione/ninhydrin. The results suggested that the 1,2-indandione/ninhydrin reagent yielded a better effect for both circulated and uncirculated RMB. For the RMB exposed to water, VMD performed better and gave limited results in terms of fingerprint development, which could serve as a reference for actual forensic cases.

  10. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Immunohistochemistry reagents and kits. 864.1860 Section 864.1860 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Biological Stains § 864.1860...

  11. Statistical validation of reagent lot change in the clinical chemistry laboratory can confer insights on good clinical laboratory practice.

    Science.gov (United States)

    Cho, Min-Chul; Kim, So Young; Jeong, Tae-Dong; Lee, Woochang; Chun, Sail; Min, Won-Ki

    2014-11-01

    Verification of new lot reagent's suitability is necessary to ensure that results for patients' samples are consistent before and after reagent lot changes. A typical procedure is to measure results of some patients' samples along with quality control (QC) materials. In this study, the results of patients' samples and QC materials in reagent lot changes were analysed. In addition, the opinion regarding QC target range adjustment along with reagent lot changes was proposed. Patients' sample and QC material results of 360 reagent lot change events involving 61 analytes and eight instrument platforms were analysed. The between-lot differences for the patients' samples (ΔP) and the QC materials (ΔQC) were tested by Mann-Whitney U tests. The size of the between-lot differences in the QC data was calculated as multiples of standard deviation (SD). The ΔP and ΔQC values only differed significantly in 7.8% of the reagent lot change events. This frequency was not affected by the assay principle or the QC material source. One SD was proposed for the cutoff for maintaining pre-existing target range after reagent lot change. While non-commutable QC material results were infrequent in the present study, our data confirmed that QC materials have limited usefulness when assessing new reagent lots. Also a 1 SD standard for establishing a new QC target range after reagent lot change event was proposed. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  12. When Students Doubt Their Teachers' Diagnostic Competence: Moderation in the Internal/External Frame of Reference Model

    Science.gov (United States)

    Zimmermann, Friederike; Möller, Jens; Köller, Olaf

    2018-01-01

    The internal/external frame of reference model (I/E model) posits that individuals' achievement-related self-concepts are formed through social comparisons (e.g., self vs. peers) within academic domains and dimensional comparisons (e.g., math vs. verbal) between distinct domains. A large body of research has supported the theorized pattern of…

  13. Stability of Loop-Mediated Isothermal Amplification (LAMP) reagents and its amplification efficiency on crude trypanosome DNA templates.

    Science.gov (United States)

    Thekisoe, Oriel M M; Bazie, Raoul S B; Coronel-Servian, Andrea M; Sugimoto, Chihiro; Kawazu, Shin-Ichiro; Inoue, Noboru

    2009-04-01

    This study evaluated the stability of LAMP reagents when stored at 25 degrees C and 37 degrees C, and also assessed its detection efficiency on different DNA template preparations. Accordingly, LAMP using reagents stored at 25 degrees C and 37 degrees C amplified DNA of in vitro cultured T. b. brucei (GUTat 3.1) from day 1 to day 15 of reagent storage. There were no significant differences (P>0.05) in detection sensitivity of LAMP among the reagents stored at 25 degrees C, 37 degrees C and -20 degrees C (recommended storage temperature). LAMP using the reagents stored at above-mentioned temperatures amplified serially diluted DNAs (genomic DNA extracted by phenol-chloroform method, FTA card and hemolysed blood) of T. b. gambiense (IL2343) with high sensitivity. Reactions were conducted on the reagents stored from 1 day to 30 days. LAMP detection sensitivity was poor when fresh blood as DNA template was added directly into reactive solution. Results of this study demonstrated that LAMP has the potential to be used in field conditions for diagnosis of trypanosome infections without being affected by ambient temperatures of tropical and sub-tropical countries where trypanosomosis is endemic.

  14. 26 CFR 1.807-2 - Cross-reference.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Cross-reference. 1.807-2 Section 1.807-2 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Investment Income § 1.807-2 Cross-reference. For special rules regarding the treatment of...

  15. 21 CFR 866.3510 - Rubella virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3510 Rubella virus... Clinical Laboratory Standards': (i) 1/LA6 “Detection and Quantitation of Rubella IgG Antibody: Evaluation... Products in the Clinical Laboratory, October 1997,” (ii) 1/LA18 “Specifications for Immunological Testing...

  16. 21 CFR 864.9225 - Cell-freezing apparatus and reagents for in vitro diagnostic use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cell-freezing apparatus and reagents for in vitro diagnostic use. 864.9225 Section 864.9225 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH... Establishments That Manufacture Blood and Blood Products § 864.9225 Cell-freezing apparatus and reagents for in...

  17. Height, weight and BMI percentiles and nutritional status relative to the international growth references among Pakistani school-aged children

    OpenAIRE

    Mushtaq, Muhammad Umair; Gull, Sibgha; Mushtaq, Komal; Abdullah, Hussain Muhammad; Khurshid, Usman; Shahid, Ubeera; Shad, Mushtaq Ahmad; Akram, Javed

    2012-01-01

    Abstract Background Child growth is internationally recognized as an important indicator of nutritional status and health in populations. This study was aimed to compare age- and gender-specific height, weight and BMI percentiles and nutritional status relative to the international growth references among Pakistani school-aged children. Methods A population-based study was conducted with a multistage cluster sample of 1860 children aged five to twelve years in Lahore, Pakistan. Smoothed heigh...

  18. How Do Drug Prices Respond to a Change from External to Internal Reference Pricing?

    DEFF Research Database (Denmark)

    Kaiser, Ulrich; Mendez, Susan J.

    (where they are based on the cheapest domestic substitute). We analyze three therapeutic classes with different treatment durations and show that the reform led to substantial price decreases for our lifelong treatment and to less substantial price reductions for our medium duration treatment while we do......We study the effects of a change in the way patient reimbursements are calculated on the prices of pharmaceuticals using quasi-experimental data for Denmark which switched from external (where reimbursements are based on prices of similar products in foreign countries) to internal reference pricing...

  19. Development of versatile isotopic labeling reagents for profiling the amine submetabolome by liquid chromatography–mass spectrometry

    International Nuclear Information System (INIS)

    Zhou, Ruokun; Huan, Tao; Li, Liang

    2015-01-01

    Highlights: • Two new reagents were developed for chemical isotope labeling mass spectrometry (MS). • They could be used to label amine-containing metabolites in a metabolomic sample. • The labeled metabolites could be detected with much improved sensitivity in MS. • One of the reagents could also help generate useful MS/MS spectra for structural analysis. • These reagents should be useful for quantitative metabolomics. - Abstract: Metabolomic profiling involves relative quantification of metabolites in comparative samples and identification of the significant metabolites that differentiate different groups (e.g., diseased vs. controls). Chemical isotope labeling (CIL) liquid chromatography–mass spectrometry (LC–MS) is an enabling technique that can provide improved metabolome coverage and metabolite quantification. However, chemical identification of labeled metabolites can still be a challenge. In this work, a new set of isotopic labeling reagents offering versatile properties to enhance both detection and identification are described. They were prepared by a glycine molecule (or its isotopic counterpart) and an aromatic acid with varying structures through a simple three-step synthesis route. In addition to relatively low costs of synthesizing the reagents, this reaction route allows adjusting reagent property in accordance with the desired application objective. To date, two isotopic reagents, 4-dimethylaminobenzoylamido acetic acid N-hydroxylsuccinimide ester (DBAA-NHS) and 4-methoxybenzoylamido acetic acid N-hydroxylsuccinimide ester (MBAA-NHS), for labeling the amine-containing metabolites (i.e., amine submetabolome) have been synthesized. The labeling conditions and the related LC–MS method have been optimized. We demonstrate that DBAA labeling can increase the metabolite detectability because of the presence of an electrospray ionization (ESI)-active dimethylaminobenzoyl group. On the other hand, MBAA labeled metabolites can be fragmented

  20. Development of versatile isotopic labeling reagents for profiling the amine submetabolome by liquid chromatography–mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Ruokun; Huan, Tao; Li, Liang, E-mail: Liang.Li@ualberta.ca

    2015-06-30

    Highlights: • Two new reagents were developed for chemical isotope labeling mass spectrometry (MS). • They could be used to label amine-containing metabolites in a metabolomic sample. • The labeled metabolites could be detected with much improved sensitivity in MS. • One of the reagents could also help generate useful MS/MS spectra for structural analysis. • These reagents should be useful for quantitative metabolomics. - Abstract: Metabolomic profiling involves relative quantification of metabolites in comparative samples and identification of the significant metabolites that differentiate different groups (e.g., diseased vs. controls). Chemical isotope labeling (CIL) liquid chromatography–mass spectrometry (LC–MS) is an enabling technique that can provide improved metabolome coverage and metabolite quantification. However, chemical identification of labeled metabolites can still be a challenge. In this work, a new set of isotopic labeling reagents offering versatile properties to enhance both detection and identification are described. They were prepared by a glycine molecule (or its isotopic counterpart) and an aromatic acid with varying structures through a simple three-step synthesis route. In addition to relatively low costs of synthesizing the reagents, this reaction route allows adjusting reagent property in accordance with the desired application objective. To date, two isotopic reagents, 4-dimethylaminobenzoylamido acetic acid N-hydroxylsuccinimide ester (DBAA-NHS) and 4-methoxybenzoylamido acetic acid N-hydroxylsuccinimide ester (MBAA-NHS), for labeling the amine-containing metabolites (i.e., amine submetabolome) have been synthesized. The labeling conditions and the related LC–MS method have been optimized. We demonstrate that DBAA labeling can increase the metabolite detectability because of the presence of an electrospray ionization (ESI)-active dimethylaminobenzoyl group. On the other hand, MBAA labeled metabolites can be fragmented

  1. Competitive roles of reagent vibration and translation in the exothermic proton transfer reaction H+2+Ar→HAr++H

    International Nuclear Information System (INIS)

    Bilotta, R.M.; Farrar, J.M.

    1981-01-01

    We present a crossed beam study of the title reaction at fixed collision energies of 1.2 and 2.3 eV with reagent H + 2 average vibrational energies of 0.44 and 0.89 eV; we also present data at fixed total energies with variable proportions of reagent vibrational and translational energy. At fixed collision energy, reagent vibrational excitation is found to have negligible effect on the total cross section for proton transfer. At fixed total energy, a decrease in reagent vibrational excitation with a corresponding increase in reagent translation leads to partial disposal of the incremental translation in product translation: At a total energy of 3.5 eV, 50% of this incremental reagent translation appears as product translation. At a total energy of 4.6 eV, 78% of the incremental translation appears in product translation. The experimental data are discussed in terms of induced attractive and repulsive energy release on an attractive potential surface. The role of noncollinear geometries and compressed reactant configurations is judged to be of substantial importance in assessing product rotational excitation and dissociation

  2. Method of Generating Hydrocarbon Reagents from Diesel, Natural Gas and Other Logistical Fuels

    Science.gov (United States)

    Herling, Darrell R [Richland, WA; Aardahl, Chris L [Richland, WA; Rozmiarek, Robert T [Middleton, WI; Rappe, Kenneth G [Richland, WA; Wang, Yong [Richland, WA; Holladay, Jamelyn D [Kennewick, WA

    2008-10-14

    The present invention provides a process for producing reagents for a chemical reaction by introducing a fuel containing hydrocarbons into a flash distillation process wherein the fuel is separated into a first component having a lower average molecular weight and a second component having a higher average molecular weight. The first component is then reformed to produce synthesis gas wherein the synthesis gas is reacted catalytically to produce the desire reagent.

  3. Sorption-reagent treatment of brines produced by reverse osmosis unit for liquid radioactive waste management

    International Nuclear Information System (INIS)

    Avramenko, V. A.; Zheleznov, V. V.; Sergienko, V. I.; Chizhevsky, I. Yu

    2003-01-01

    The results of the pilot plant tests (2002-2003) of the sorption-reagent decontamination of high salinity radioactive waste (brines) remaining after the low-salinity liquid radioactive waste (LRW) treatment in the reverse-osmosis unit from long-lived radionuclides are presented. The sorption-reagent materials used in this work were developed in the Institute of Chemistry FEDRAS. They enable one to decontaminate brines with total salt content up to 50 g/l from long-lived radionuclides of Cs, Sr and Co. At joint application of the reverse-osmosis and sorption-reagent technologies total volume of solid radioactive waste (SRW) decreases up to 100-fold as compared to the technology of cementation of reverse osmosis brines. In this case total cost of LRW treatment and SRW disposal decreases more than 10-fold. Brines decontaminated from radionuclides are then diluted down to the ecologically safe total salts content in water to be disposed of. Tests were performed to compare the efficiency of technologies including evaporation of brines remaining after reverse osmosis process and their decontamination by means of the sorption-reagent method. It was shown that, as compared to evaporation, the sorption-reagent technology provides substantial advantages as in regard to radioactive waste total volume reduction as in view of total cost of the waste management

  4. 21 CFR 866.3390 - Neisseria spp. direct serological test reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3390... Neisseria spp. directly from clinical specimens. The identification aids in the diagnosis of disease caused...

  5. Protein-Protein Interaction Reagents | Office of Cancer Genomics

    Science.gov (United States)

    The CTD2 Center at Emory University has a library of genes used to study protein-protein interactions in mammalian cells. These genes are cloned in different mammalian expression vectors. A list of available cancer-associated genes can be accessed below. Emory_CTD^2_PPI_Reagents.xlsx Contact: Haian Fu

  6. [Thermodynamic forecasting of reagents composition for soils decontamination].

    Science.gov (United States)

    Nikolaev, V P; Nikolaevskiĭ, V B; Chirkina, I V; Shcheglov, M Iu

    2009-01-01

    Based on thermodynamic studies, the authors conducted laboratory experiments on searching optimal composition of leaching reagents solution for soils decontamination, when contaminated with Cs-137, of activity coefficient for caesium sulfate microquantities in macrocomponents solutions. The method could be used for modelling the radionuclides phase equillibrium and relocations in soils.

  7. Reagent strip testing is not sensitive for the screening of asymptomatic bacteriuria in pregnant women.

    Science.gov (United States)

    Lumbiganon, Pisake; Chongsomchai, Chompilas; Chumworathayee, Bundit; Thinkhamrop, Jadsada

    2002-08-01

    The objective of the study was to assess the diagnostic performance of the reagent strip in screening for asymptomatic bacteriuria in pregnant women using urine culture as a gold standard. This study comprised 204 asymptomatic pregnant women who attended their first antenatal care at Srinagarind Hospital, Khon Kaen University from April 1, 1999 to June 30, 1999. Women with symptoms of urinary tract infection, antibiotic treatment within the previous 7 days, pregnancy-induced hypertension, bleeding per vagina and history of urinary tract diseases were excluded. Urine specimens were collected by clean catched midstream urine technique for urinalysis, reagent strip test and urine culture. Diagnostic performance of reagent strip in terms of sensitivity, specificity, positive and negative predictive value was analyzed. Urine reagent strip test had a sensitivity of 13.9 per cent, a specificity of 95.6 per cent, a positive predictive value of 46.1 per cent, a negative predictive value of 80.6 per cent in detecting asymptomatic bacteriuria in pregnant women.

  8. Evaluation of Questionnaire, Reagent Strip and Egg Count as ...

    African Journals Online (AJOL)

    A longitudinal study covering 55 months evaluated the three diagnostic tools used for confirmation of prevalence of urinary schistosomiasis among 1151 consented primary school pupils in 13 communities of Edo State, Nigeria. Questionnaire, reagent strip method and parasitological examination were employed.

  9. Manganese-Catalyzed Aerobic Heterocoupling of Aryl Grignard Reagents

    DEFF Research Database (Denmark)

    Ghaleshahi, Hajar Golshahi; Antonacci, Giuseppe; Madsen, Robert

    2017-01-01

    An improved protocol has been developed for the MnCl2-catalyzed cross-coupling reaction of two arylmagnesium bromides under dioxygen. The reaction was achieved by using the Grignard reagents in a 2:1 ratio and 20 % of MnCl2. Very good yields of the heterocoupling product were obtained when the li...

  10. Recyclable bio-reagent for rapid and selective extraction of contaminants from soil

    International Nuclear Information System (INIS)

    Lomasney, H.L.

    1997-01-01

    This Phase I Small Business Innovation Research program is confirming the effectiveness of a bio-reagent to cost-effectively and selectively extract a wide range of heavy metals and radionuclide contaminants from soil. This bioreagent solution, developed by ISOTRON reg-sign Corporation (New Orleans, LA), is flushed through the soil and recycled after flowing through an electrokinetic separation module, also developed by ISOTRON reg-sign. The process is ex situ, and the soil remains in its transport container through the decontamination process. The transport container can be a fiberglass box, or a bulk bag or open-quotes super sack.close quotes Rocks, vegetation, roots, etc. need not be removed. High clay content soils are accommodated. The process provides rapid injection of reagent solution, and when needed, sand is introduced to speed up the heap leach step. The concentrated waste form is eventually solidified. The bio-reagent is essentially a natural product, therefore any solubizer residual in soil is not expected to cause regulatory concern. The Phase I work will confirm the effectiveness of this bio-reagent on a wide range of contaminants, and the engineering parameters that are needed to carry out a full-scale demonstration of the process. ISOTRON reg-sign scientists will work with contaminated soil from Los Alamos National Laboratory. LANL is in the process of decontaminating and decommissioning more than 300 sites within its complex, many of which contain heavy metals or radionuclides; some are mixed wastes containing TCE, PCB, and metals

  11. Recyclable bio-reagent for rapid and selective extraction of contaminants from soil

    Energy Technology Data Exchange (ETDEWEB)

    Lomasney, H.L. [ISOTRON Corp., New Orleans, LA (United States)

    1997-10-01

    This Phase I Small Business Innovation Research program is confirming the effectiveness of a bio-reagent to cost-effectively and selectively extract a wide range of heavy metals and radionuclide contaminants from soil. This bioreagent solution, developed by ISOTRON{reg_sign} Corporation (New Orleans, LA), is flushed through the soil and recycled after flowing through an electrokinetic separation module, also developed by ISOTRON{reg_sign}. The process is ex situ, and the soil remains in its transport container through the decontamination process. The transport container can be a fiberglass box, or a bulk bag or {open_quotes}super sack.{close_quotes} Rocks, vegetation, roots, etc. need not be removed. High clay content soils are accommodated. The process provides rapid injection of reagent solution, and when needed, sand is introduced to speed up the heap leach step. The concentrated waste form is eventually solidified. The bio-reagent is essentially a natural product, therefore any solubizer residual in soil is not expected to cause regulatory concern. The Phase I work will confirm the effectiveness of this bio-reagent on a wide range of contaminants, and the engineering parameters that are needed to carry out a full-scale demonstration of the process. ISOTRON{reg_sign} scientists will work with contaminated soil from Los Alamos National Laboratory. LANL is in the process of decontaminating and decommissioning more than 300 sites within its complex, many of which contain heavy metals or radionuclides; some are mixed wastes containing TCE, PCB, and metals.

  12. [A stable reagent for the-single stage determination of inorganic phosphate].

    Science.gov (United States)

    Pupyshev, A B

    1991-01-01

    A recipe of a simple reagent for phosphorus detection has been developed, consisting of ammonium molybdate (4 mM), sulfuric acid (0.2 N), and Tween-80 (0.2%). The developing phosphate staining may be registered in 15 min at a wavelength of 350 nm. The product molar extinction is equal to 1.20.10(4) M-1.cm-1, this being close to that of molybdic blue. Phosphate staining is characterized by the stability of results and insensitivity to the presence of a number of substances used in enzymology. The prepared reagent is fit for experiments within a fortnight if stored in the cold.

  13. Internal dosimetry estimates using voxelized reference phantoms for thyroid agents

    International Nuclear Information System (INIS)

    Hoseinian-Azghadi, E.; Rafat-Motavalli, L.; Miri-Hakimabad, H.

    2014-01-01

    This work presents internal dosimetry estimates for diagnostic procedures performed for thyroid disorders by relevant radiopharmaceuticals. The organ doses for 131 Iodine, 123 Iodine and 99m Tc incorporated into the body were calculated for the International Commission on Radiological Protection (ICRP) reference voxel phantoms using the Monte Carlo transport method. A comparison between different thyroid uptakes of iodine in the range of 0–55% was made, and the effect of various techniques for administration of 99m Tc on organ doses was studied. To investigate the necessity of calculating organ dose from all source regions, the major source organ and its contribution to total dose were specified for each target organ. Moreover, we compared effective dose in ICRP voxel phantoms with that in stylized phantoms. In our method, we directly calculated the organ dose without using the S values or SAFs, as is commonly done. Hence, a distribution of the absorbed dose to entire tissues was obtained. The chord length distributions (CLDs) were also computed for the selected source–target pairs to make comparison across the genders. The results showed that the S values for radionuclides in the thyroid are not sufficient for calculating the organ doses, especially for 123 I and 99m Tc. The thyroid and its neighboring organs receive a greater dose as thyroid uptake increases. Our comparisons also revealed an underestimation of organ doses reported for the stylized phantoms compared with the values based on the ICRP voxel phantoms in the uptake range of 5–55%, and an overestimation of absorbed dose by up to 2-fold for Iodine administration using blocking agent and for 99m Tc incorporation. (author)

  14. The blocking reagent optimization for the magnetoelastic biosensor

    Science.gov (United States)

    Hu, Jiajia; Chai, Yating; Horikawa, Shin; Wikle, Howard C.; Wang, Feng'en; Du, Songtao; Chin, Bryan A.; Hu, Jing

    2015-06-01

    The wireless phage-based magnetoelastic (ME) biosensor has proven to be promising for real-time detection of pathogenic bacteria on fresh produces. The ME biosensor consists of a freestanding ME resonator as the signal transducer and filamentous phage as the biomolecular-recognition element, which can specifically bind to a pathogen of interest. Due to the Joule magnetostriction effect, the biosensors can be placed into mechanical resonance when subjected to a time-varying magnetic field alternating at the sensor's resonant frequency. Upon the attachment of the target pathogen, the mass of the biosensor increases, thereby decreasing its resonant frequency. This paper presents an investigation of blocking reagents immobilization for detecting Salmonella Typhimurium on fresh food surfaces. Three different blocking reagents (BSA, SuperBlock blocking buffer, and blocker BLOTTO) were used and compared. The optical microscope was used for bacterial cells binding observation. Student t-test was used to statistically analysis the experiment results. The results shows that SuperBlock blocking buffer and blocker BLOTTO have much better blocking performance than usually used BSA.

  15. ETAC reagents: A new class of sulfhydryl site-specific radiolabelling probes for antibodies

    International Nuclear Information System (INIS)

    del Rosario, R.B.; Brocchini, S.J.; Baron, L.A.; Smith, R.H.; Lawton, R.G.; Wahl, R.L.

    1990-01-01

    A new class of bis-alkylating Michael reagents, equilibrium transfer crosslink reagents, 'ETAC', which combine the techniques of crosslinking with tethering have been synthesized. Following a succession of Michael and retro-Michael additions and elimination of the arylsulfone groups, reduced heavy-heavy and heavy-light disulfide links of an anti-ovarian IgG2a monoclonal antibody, 5G6.4, were site-specifically re-annealed via a 3-carbon bridge having a tether branch containing a designated label

  16. Small-scale extraction and radioiodination of human hormones for the substitution of imported radioimmunoassay reagents

    International Nuclear Information System (INIS)

    Gimbo, E.K.; Ribela, M.T.C.P.; Borghi, V.C.; Schwarz, I.; Morganti, L.; Araujo, E.A.; Bartolini, P.

    1988-01-01

    The methods for national production of radioimmunoassay reagents to substitute imported kits of: highly purified unlabelled hormones for radioiodination; 125 I-labelled hormones; and specific high titre antisera are presented. The extraction and purification of human growth hormone (hGH) and human luteinizing hormone (hGH) were done from human pituitaries. The 125 I-labelled hormones are obtained by stoichiometric methods. The 125 I-hGH, 125 I-hLH, I-hTSH and 125 I- h calcitonin were prepared and tested in internal and external quality control, in comparison with imported products. The parameters such as: maximum binding to specific antiserum (Bo), nonspecific binding (NSB), mean effective dose (ED 50), sensitivity and accuracy were evaluated. (M.C.K.) [pt

  17. Peptide bond-forming reagents HOAt and HATU are not mutagenic in the bacterial reverse mutation test.

    Science.gov (United States)

    Nicolette, John; Neft, Robin E; Vanosdol, Jessica; Murray, Joel

    2016-04-01

    The peptide bond-forming reagents 1-hydroxy-7-azabenzotriazole (HOAt, CAS 39968-33-7) and O-(7-Azabenzotriazol-1-yl)-N,N,N',N'-tetramethyluronium hexafluorophosphate (HATU, CAS 148893-10-1) either have structural alerts, unclassified features or are considered out of domain when evaluated for potential mutagenicity with in silico programs DEREK and CaseUltra. Since they are commonly used reagents in pharmaceutical drug syntheses, they may become drug substance or drug product impurities and would need to be either controlled to appropriately safe levels or tested for mutagenicity. Both reagents were tested in the bacterial reverse mutation (Ames) test at Covance, under GLP conditions, following the OECD test guideline and ICH S2(R1) recommendations and found to be negative. Our data show that HOAt and HATU-common pharmaceutical synthesis reagents-are not mutagenic, and can be treated as ordinary drug impurities. © 2016 Wiley Periodicals, Inc.

  18. Palladium-catalysed direct cross-coupling of secondary alkyllithium reagents

    NARCIS (Netherlands)

    Vila, Carlos; Giannerini, Massimo; Hornillos, Valentin; Fananas-Mastral, Martin; Feringa, Ben L.

    2014-01-01

    Palladium-catalysed cross-coupling of secondary C(sp(3)) organometallic reagents has been a long-standing challenge in organic synthesis, due to the problems associated with undesired isomerisation or the formation of reduction products. Based on our recently developed catalytic C-C bond formation

  19. SATL Based Lesson for Teaching Grignard Reagents in Synthetic ...

    African Journals Online (AJOL)

    Synthesizing new products from raw materials has been very popular aspects of research in organic chemistry. Traditionally, Grignard reagent has been very vital component of such synthetic procedures. Hence learning of various issues concerning with applications of Grignard reactions in synthetic organic chemistry is ...

  20. Extending IM beyond the Reference Desk: A Case Study on the Integration of Chat Reference and Library-Wide Instant Messaging Network

    Directory of Open Access Journals (Sweden)

    Ian Chan

    2012-09-01

    Full Text Available Openfire is an open source IM network and a single unified application that meets the needs of chat reference and internal communications. In Fall 2009, the California State University San Marcos (CSUSM Library began use of Openfire and other Jive software instant messaging technologies, to simultaneously improve our existing IM-integrated chat reference software and implement an internal IM network. This case study describes the chat reference and internal communications environment at the CSUSM Library and the selection, implementation, and evaluation of Openfire. In addition, the authors discuss the benefits of deploying an integrated instant messaging and chat reference network.

  1. [The development of reagents set in the format of DNA-chip for genetic typing of strains of Vibrio cholerae].

    Science.gov (United States)

    Pudova, E A; Markelov, M L; Dedkov, V G; Tchekanova, T A; Sadjin, A I; Kirdiyashkina, N P; Bekova, M V; Deviyatkin, A A

    2014-05-01

    The necessity of development of methods of genic diagnostic of cholera is conditioned by continuation of the Seventh pandemic of cholera, taxonomic variability of strains of Vibrio cholerae involved into pandemic and also permanent danger of delivery of disease to the territory of the Russian Federation. The methods of genic diagnostic of cholera make it possible in a comparatively short time to maximally minutely characterize strains isolated from patients or their environment. The article presents information about working out reagents set for genetic typing of agents of cholera using DNA-chip. The makeup of DNA-chip included oligonucleotide probes making possible to differentiate strains of V. cholerae on serogroups and biovars and to determine their pathogenicity. The single DNA-chip makes it possible to genetically type up to 12 samples concurrently. At that, duration of analysis without accounting stage of DNA separation makes up to 5 hours. In the progress of work, 23 cholera and non-cholera strains were analyzed. The full compliance of DNA-chip typing results to previously known characteristics of strains. Hence, there is a reason to consider availability of further development of reagents set and possibility of its further application in laboratories of regional level and reference centers.

  2. Evaluation of Enoyl-Acyl Carrier Protein Reductase Inhibitors as Pseudomonas aeruginosa Quorum-Quenching Reagents

    DEFF Research Database (Denmark)

    Yang, Liang; Liu, Yang; Sternberg, Claus

    2010-01-01

    Pseudomonas aeruginosa is an opportunistic pathogen which is responsible for a wide range of infections. Production of virulence factors and biofilm formation by P. aeruginosa are partly regulated by cell-to-cell communication quorum-sensing systems. Identification of quorum-quenching reagents...... which block the quorum-sensing process can facilitate development of novel treatment strategies for P. aeruginosa infections. We have used molecular dynamics simulation and experimental studies to elucidate the efficiencies of two potential quorum-quenching reagents, triclosan and green tea...... epigallocatechin gallate (EGCG), which both function as inhibitors of the enoyl-acyl carrier protein (ACP) reductase (ENR) from the bacterial type II fatty acid synthesis pathway. Our studies suggest that EGCG has a higher binding affinity towards ENR of P. aeruginosa and is an efficient quorum-quenching reagent...

  3. Exploring the Potential for Using Inexpensive Natural Reagents Extracted from Plants to Teach Chemical Analysis

    Science.gov (United States)

    Hartwell, Supaporn Kradtap

    2012-01-01

    A number of scientific articles report on the use of natural extracts from plants as chemical reagents, where the main objective is to present the scientific applications of those natural plant extracts. The author suggests that natural reagents extracted from plants can be used as alternative low cost tools in teaching chemical analysis,…

  4. International Congress on Analytical Chemistry. Abstracts. V. 1

    International Nuclear Information System (INIS)

    1997-01-01

    The collection of materials of the international congress on analytical chemistry taken place in Moscow in June 1997. The main directs of investigations in such regions of analytical chemistry as quantitative and qualitative analysis, microanalysis, sample preparation and preconcentration, analytical reagents, chromatography and related techniques, flow analysis, electroanalytical and kinetic methods sensors are elucidated

  5. Reliability of Reagent Strips for Semi-quantitative Measurement of Glucosuria in a Neonatal Intensive Care Setting

    Directory of Open Access Journals (Sweden)

    Jolita Bekhof

    2014-12-01

    Conclusion: The reliability of the semi-quantitative measurement of glucosuria in newborn infants using reagent strips is good, even under the conditions of a NICU. Changes in the rating of reagent strips of more than one category are most likely to be beyond measurement error.

  6. International panoram and Spanish contribution to the dissemination and evaluation of reference data for the ionizing radiations: Project BANDRRI

    International Nuclear Information System (INIS)

    Los Arcos, J.M.; Gonzalez, A.; Bailador, A.; Gonzalez, A.; Sanchez, E.; Gorostiza, C.; Ortiz, F.

    1998-01-01

    The present work shows the international panorama of the diverse sources of reference data commonly used in the environment of the radiations ionizantes, as well as the organized Spanish contribution recently around the project of the database of Reference for the radiations ionizantes (BANDRRI), developed jointly by the Unit of Metrology of Ionizing Radiations (UMRI) of the center of Environmental and Technological Investigations (CIEMAT), clerk of the Ministry of Industry and Spanish Energy, the University of Education to Distance and the Address of Computer science of the CIEMAT

  7. A highly efficient dual-diazonium reagent for protein crosslinking and construction of a virus-based gel.

    Science.gov (United States)

    Ma, Dejun; Zhang, Jie; Zhang, Changyu; Men, Yuwen; Sun, Hongyan; Li, Lu-Yuan; Yi, Long; Xi, Zhen

    2018-05-09

    A new bench-stable reagent with double diazonium sites was designed and synthesized for protein crosslinking. Based on the highly efficient diazonium-Tyr coupling reaction, a direct mixture of the reagent and tobacco mosaic virus led to the formation of a new hydrogel, which could be degraded by chemicals and could be used to encapsulate small molecules for sustained release. Because plant viruses exhibit many chemical characteristics like protein labelling and nucleic acid packaging, the virus-based hydrogel will have large chemical space for further functionalization. Besides, this dual-diazonium reagent should be a generally useful crosslinker for chemical biology and biomaterials.

  8. APPLICATION OF FENTON’S REAGENT ON REMEDIATION OF POLYCYCLIC AROMATIC HYDROCARBONs (PAHs IN SPIKED SOIL

    Directory of Open Access Journals (Sweden)

    Nursiah La Nafie

    2010-06-01

    Full Text Available Problem associated with Polycyclic Aromatic Hydrocarbons (PAHs contaminated site in environmental media have received increasing attention. To resolve such problems, innovative in situ methods are urgently required. This work investigated the feasibility of using Fenton's Reagent to remediate PAHs in spiked soil. PAHs were spiked into soil to simulate contaminated soil. Fenton's Reagent (H2O2 + Fe2+ and surfactant were very efficient in destruction of PAHs including naphthalene, anthracene, fluoranthene, pyrene, and benzo(apyrene from spiked soil. It was indicated by the fact that more than 96% of PAHs were degraded in the solution and the spiked soil.   Keywords: Environmental, Fenton's Reagent, Polycyclic Aromatic Hydrocarbons, and Spiked soil.

  9. Selenium and tellurium reagents in organic synthesis

    International Nuclear Information System (INIS)

    Comasseto, J.V.

    1984-01-01

    A review of the contribution of the University of Sao Paulo (SP, Brazil) to the organic synthesis of selenium and tellurium reagents is made. Major reactions amoung selenium compounds and insaturated substrates, phosphorus, ester enolates as well as the use of phase transference catalysed reactions to produce arylselenolate are described. For tellurium, interactions of its compounds with organic substrates and reactive intermediates (e.g. benzino diazomethane) are reported. (C.L.B.) [pt

  10. Reference sources for the calibration of surface contamination monitors - Beta-emitters (maximum beta energy greater than MeV) and alpha-emitters (International Standard Publication ISO 8769:1988)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    This International Standard specifies the characteristics of reference sources of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This International Standard relates to alpha-emitters and to beta-emitters of maximum beta energy greater than 0,15 MeV. It does not describe the procedures involved in the use of these reference sources for the calibration of surface contamination monitors. Such procedures are specified in IEC Publication 325 and other documents. This International Standard specifies reference radiations for the calibration of surface contamination monitors which take the form of adequately characterized large area sources specified, without exception, in terms of activity and surface emission rate, the evaluation of these quantities being traceable to national standards

  11. The hydrogen sulfide donor, Lawesson's reagent, prevents alendronate-induced gastric damage in rats

    International Nuclear Information System (INIS)

    Nicolau, L.A.D.; Silva, R.O.; Damasceno, S.R.B.; Carvalho, N.S.; Costa, N.R.D.; Aragão, K.S.; Barbosa, A.L.R.; Soares, P.M.G.; Souza, M.H.L.P.; Medeiros, J.V.R.

    2013-01-01

    Our objective was to investigate the protective effect of Lawesson's reagent, an H 2 S donor, against alendronate (ALD)-induced gastric damage in rats. Rats were pretreated with saline or Lawesson's reagent (3, 9, or 27 µmol/kg, po) once daily for 4 days. After 30 min, gastric damage was induced by ALD (30 mg/kg) administration by gavage. On the last day of treatment, the animals were killed 4 h after ALD administration. Gastric lesions were measured using a computer planimetry program, and gastric corpus pieces were assayed for malondialdehyde (MDA), glutathione (GSH), proinflammatory cytokines [tumor necrosis factor (TNF)-α and interleukin (IL)-1β], and myeloperoxidase (MPO). Other groups were pretreated with glibenclamide (5 mg/kg, ip) or with glibenclamide (5 mg/kg, ip)+diazoxide (3 mg/kg, ip). After 1 h, 27 µmol/kg Lawesson's reagent was administered. After 30 min, 30 mg/kg ALD was administered. ALD caused gastric damage (63.35±9.8 mm 2 ); increased levels of TNF-α, IL-1β, and MDA (2311±302.3 pg/mL, 901.9±106.2 pg/mL, 121.1±4.3 nmol/g, respectively); increased MPO activity (26.1±3.8 U/mg); and reduced GSH levels (180.3±21.9 µg/g). ALD also increased cystathionine-γ-lyase immunoreactivity in the gastric mucosa. Pretreatment with Lawesson's reagent (27 µmol/kg) attenuated ALD-mediated gastric damage (15.77±5.3 mm 2 ); reduced TNF-α, IL-1β, and MDA formation (1502±150.2 pg/mL, 632.3±43.4 pg/mL, 78.4±7.6 nmol/g, respectively); lowered MPO activity (11.7±2.8 U/mg); and increased the level of GSH in the gastric tissue (397.9±40.2 µg/g). Glibenclamide alone reversed the gastric protective effect of Lawesson's reagent. However, glibenclamide plus diazoxide did not alter the effects of Lawesson's reagent. Our results suggest that Lawesson's reagent plays a protective role against ALD-induced gastric damage through mechanisms that depend at least in part on activation of ATP-sensitive potassium (K ATP ) channels

  12. Functions of chalcogenide electrodes in solutions of complexing reagents and interfering ions

    International Nuclear Information System (INIS)

    Kiyanskij, V.V.

    1990-01-01

    The possibility to modify chalcogenide electrodes and their behaviour in solutions of complexing reagents for the development of new methods of potentiometric titration has been studied. It is shown that complexing reagents (EDTA, cupferron, 8-hydroxyquinoline, sodium dithiocarbaminate) and Cu(2), Hg(2) produce a strong effect on the functions of Ag, Cu, Cd, Pb - selective electrodes, which is used for titration of potential-determining and non-potential-determining ions ions (Sr 2+ , La 3+ etc.) and also for modification of sulfide-selecting electrode. A method of potentiometric titration of sulfates and chlorides with modified Cd- and Ag-selective electrodes is suggested

  13. Oxytetracycline as a new analytical reagent for the spectrophotometric determination of boron

    International Nuclear Information System (INIS)

    Narayana, G.L.

    1984-01-01

    Oxytetracycline hydrochloride, Terramycin, is introduced as a new reagent for the spectrophotometric determination of trace quantities of boron in concentrated sulphuric acid medium. The reagent has an absorption maximum at 430 nm, and that of the boron complex at 520 nm. The coloured system conformed to Beer's law between 2 and 10 μg of boron at 520 nm. The molar absorptivity calculated on the basis of boron is 10,800 1 mol -1 cm -1 . The composition of the complex has been shown to be 1:1 both by the slope ratio and molar ratio methods. (author)

  14. THE USE OF GRIGNARD REAGENT IN PHEROMONE SYNTHESIS FOR PALM WEEVIL (Rhynchorus, Sp

    Directory of Open Access Journals (Sweden)

    Warsito Warsito

    2010-06-01

    Full Text Available In an integrated controlling system of palm weevil, using of synthetic feromoid is strickly needed. The research is aimed to synthesize pheromone which secreted by the weevil, e.g. 4-methyl-5-nonanol (R. ferrugineus and 3-methyl-4-octanol (R. schach through Grignard reagent which formed in situ. The synthesis was proceded by retrosynthesis to determine the precursor, valeraldehyde. The precursor was reacted with Grignard reagent of sec-amyl magnesium bromide (R. ferrugenieus and sec-butyl magnesium bromide (R. shach which made in situ. Characterization of the synthetic molecular pheromone was performed by Gas Chromatography-mass spectroscopy and Fourier Transformed Infra Red. The bioassay of the molecule was carried out by olfactometer. The result showed that the conversion of the reactions were 51.28% (4-methyl-5-nonanol and 85.90% (3-methyl-4-octanol. The character of physico-chemical and bioactivity of the synthetic pheromone are identic with natural pheromones.   Keywords: palm weevil, pheromone, grignard reagent

  15. FALSIRE Phase II. CSNI project for Fracture Analyses of Large-Scale International Reference Experiments (Phase II). Comparison report

    International Nuclear Information System (INIS)

    Sievers, J.; Schulz, H.; Bass, R.; Pugh, C.; Keeney, J.

    1996-11-01

    A summary of Phase II of the Project for Fracture Analysis of Large-Scale International Reference Experiments (FALSIRE) is presented. A FALSIRE II Workshop focused on analyses of reference fracture experiments. More than 30 participants representing 22 organizations from 12 countries took part in the workshop. Final results for 45 analyses of the reference experiments were received from the participating analysts. For each experiment, analysis results provided estimates of variables that include temperature, crack-mouth-opening displacement, stress, strain, and applied K and J values. The data were sent electronically to the Organizing Committee, who assembled the results into a comparative data base using a special-purpose computer program. A comparative assessment and discussion of the analysis results are presented in the report. Generally, structural responses of the test specimens were predicted with tolerable scatter bands. (orig./DG)

  16. Inactivation and stability of viral diagnostic reagents treated by gamma radiation

    International Nuclear Information System (INIS)

    White, L.A.; Freeman, C.Y.; Hall, H.E.; Forrester, B.D.

    1990-01-01

    The objective of this study was to apply the pertinent findings from gamma inactivation of virus infectivity to the production of high quality diagnostic reagents. A Gammacell 220 was used to subject 38 viruses grown in either susceptible tissue cultures or embryonated chicken eggs to various doses of gamma radiation from a cobalt-60 source. The radiation required to reduce viral infectivity was 0.42 to 3.7 megarads (Mrad). The effect of gamma treatment on the antigenic reactivity of reagents for the complement fixation (CF), hemagglutination (HA) and neuraminadase assays was determined. Influenza antigens inactivated with 1.7 Mrad displayed comparable potency, sensitivity, specificity and stability to those inactivated by standard procedures with beta-propiolactone (BPL). Significant inactivation of influenza N1 and B neuraminidase occurred with >2.4 Mrad radiation at temperatures above 4 0 C. All 38 viruses were inactivated, and CF or HA antigens were prepared successfully. Antigenic potency remained stable with all antigens for 3 years and with 83% after 5 years storage. Influenza HA antigens evaluated after 9 years of storage demonstrated 86% stability. Gamma radiation is safer than chemical inactivation procedures and is a reliable and effective replacement for BPL in preparing diagnostic reagents. (author)

  17. Inactivation and stability of viral diagnostic reagents treated by gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    White, L A; Freeman, C Y; Hall, H E; Forrester, B D [Department of Health and Human Services, Atlanta, GA (USA)

    1990-10-01

    The objective of this study was to apply the pertinent findings from gamma inactivation of virus infectivity to the production of high quality diagnostic reagents. A Gammacell 220 was used to subject 38 viruses grown in either susceptible tissue cultures or embryonated chicken eggs to various doses of gamma radiation from a cobalt-60 source. The radiation required to reduce viral infectivity was 0.42 to 3.7 megarads (Mrad). The effect of gamma treatment on the antigenic reactivity of reagents for the complement fixation (CF), hemagglutination (HA) and neuraminadase assays was determined. Influenza antigens inactivated with 1.7 Mrad displayed comparable potency, sensitivity, specificity and stability to those inactivated by standard procedures with beta-propiolactone (BPL). Significant inactivation of influenza N1 and B neuraminidase occurred with >2.4 Mrad radiation at temperatures above 4{sup 0}C. All 38 viruses were inactivated, and CF or HA antigens were prepared successfully. Antigenic potency remained stable with all antigens for 3 years and with 83% after 5 years storage. Influenza HA antigens evaluated after 9 years of storage demonstrated 86% stability. Gamma radiation is safer than chemical inactivation procedures and is a reliable and effective replacement for BPL in preparing diagnostic reagents. (author).

  18. The behavior of thiourea and flotation reagents in zinc electrowinning circuits

    Science.gov (United States)

    MacKinnon, D. J.; Dutrizac, J. E.; Brannen, J. M.; Hardy, D. J.

    1988-04-01

    The effect of thiourea and flotation reagents on the electrowinning of zinc from industrial electrolytes was studied, and all the compounds were found to reduce the zinc deposition current efficiency and to change the properties of the zinc deposits. The effectiveness of activated carbon, two-stage cementation, and hot acid leaching on the destruction/removal of the organic compounds also was addressed. Activated carbon pretreatment of thiourea-containing electrolytes restored the current efficiency for 1-hour zinc deposits to values comparable to those obtained for thiourea-free electrolytes. The activated carbon pretreatment, however, altered the deposit morphology and orientation, but produced a cyclic voltammogram similar to that of the thiourea-free solution. Two-stage cementation did not counteract the harmful effects of thiourea. Hot acid leaching destroyed the thiourea but generated large concentrations of ferrous ion that reduced the current efficiency. The ferrous concentrations, however, were readily controlled by KMnO4 or MnO2 oxidation. None of the treatment options (activated carbon, two-stage cementation, or hot acid leaching) was effective in controlling the flotation reagents, and their moderately harmful effect on zinc electrowinning persisted. Even low concentrations of these reagents polarized zinc deposition, and this resulted in a “glue-type” zinc deposit.

  19. Extraction of uranium(6), transuranium elements and europium by bidentate neutral phosphorus- and phosphorus-nitrogen-containing reagents with substituent in methylene bridge

    International Nuclear Information System (INIS)

    Kochetkova, N.E.; Kojro, O.Eh.; Nesterova, N.P.; Medved', T.Ya.; Chmutova, M.K.; Myasoedov, B.F.; Kabachnik, M.I.

    1986-01-01

    The influence of substituents in methylene bridge on solubility, extractivity and selectivity of bidentate neutral phosphorus- and phosphorus-nitrogen-containing reagents in the process of U(6), TUE, Eu extraction has been studied. It is ascertained that hydrogen substitution in the bridge of tetraphenylmethylenediphosphine dioxide (1) causes a decrease in the extractivity of reagent as to TPE, uranium (6) and europium. There is no visible regular relation between basicity and extractivity of substituted reagents. Hydrogen substitution in the bridge of diphenyl[diethylcarbamoylmethyl]phosphine oxide (2) causes a decrease in extractivity of the reagent as to TPE, uranium (6) and europium. In contrast to monodentate neutral reagents, when bidentate neutral reagents are used, sometimes no increase in the reagent extractivity with an increase in its basicity is observed. When fragments restricting the conformation mobility of bidentate reagent molecule are introduced in it (here substituents in methylene bridge), it may result in the violation of the regularity, since of all the factors affecting the reagent extractivity the spatial factor may become the prevailing one. On hydrogen substitution in the bridge of 1 separation factors of practically all (with few exceptions) studied pairs of elements increase. Hydrogen substitution in the bridge of 2 causes an increase in separation factor of U (6) /Am pair and it does not affect the separation factor of Am/Eu pair. Hydrogen substitution in the bridge of 1 and 2 does not result in the preparation of more efficient and considerably more selective reagents for extractive isolation and separation of the elements, but some of the substituted reagents (Cl-substituted 1, for instance) may turn out useful for the element separation

  20. Reaction of lupane and oleanane triterpenoids with Lawesson's reagent

    Czech Academy of Sciences Publication Activity Database

    Kvasnica, Miroslav; Rudovská, I.; Císařová, I.; Šarek, J.

    2008-01-01

    Roč. 64, č. 17 (2008), s. 3736-3743 ISSN 0040-4020 Grant - others:GA ČR(CZ) GP203/05/P025 Institutional research plan: CEZ:AV0Z40550506 Keywords : terpenoids * Lawesson's reagent * ketones * sulfur Subject RIV: CC - Organic Chemistry Impact factor: 2.897, year: 2008

  1. Systematic Evaluation of Protein Reduction and Alkylation Reveals Massive Unspecific Side Effects by Iodine-containing Reagents.

    Science.gov (United States)

    Müller, Torsten; Winter, Dominic

    2017-07-01

    Reduction and alkylation of cysteine residues is part of virtually any proteomics workflow. Despite its frequent use, up to date no systematic investigation of the impact of different conditions on the outcome of proteomics studies has been performed. In this study, we compared common reduction reagents (dithiothreitol, tris-(2-carboxyethyl)-phosphine, and β-mercaptoethanol) and alkylation reagents (iodoacetamide, iodoacetic acid, acrylamide, and chloroacetamide). Using in-gel digests as well as SAX fractionated in-solution digests of cytosolic fractions of HeLa cells, we evaluated 13 different reduction and alkylation conditions resulting in considerably varying identification rates. We observed strong differences in offsite alkylation reactions at 7 amino acids as well as at the peptide N terminus, identifying single and double adducts of all reagents. Using dimethyl labeling, mass tolerant searches, and synthetic peptide experiments, we identified alkylation of methionine residues by iodine-containing alkylation reagents as one of the major factors for the differences. We observed differences of more than 9-fold in numbers of identified methionine-containing peptide spectral matches for in-gel digested samples between iodine- and noniodine-containing alkylation reagents. This was because of formation of carbamidomethylated and carboxymethylated methionine side chains and a resulting prominent neutral loss during ESI ionization or in MS/MS fragmentation, strongly decreasing identification rates of methionine-containing peptides. We achieved best results with acrylamide as alkylation reagent, whereas the highest numbers of peptide spectral matches were obtained when reducing with dithiothreitol and β-mercaptoethanol for the in-solution and the in-gel digested samples, respectively. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  2. Identification of mimotopes of Mycobacterium leprae as potential diagnostic reagents

    Directory of Open Access Journals (Sweden)

    Alban Silvana M

    2013-01-01

    Full Text Available Abstract Background An early diagnostic test for detecting infection in leprosy is fundamental for reducing patients’ sequelae. The currently used lepromin is not adequate for disease diagnosis and, so far, no antigen to be used in intradermoreaction has proved to be sensitive and specific for that purpose. Aiming at identifying new reagents to be used in skin tests, candidate antigens were investigated. Methods Random peptide phage display libraries were screened by using antibodies from leprosy patients in order to identify peptides as diagnostic reagents. Results Seven different phage clones were identified using purified antibodies pooled from sera of leprosy patients. When the clones were tested with serum samples by ELISA, three of them, 5A, 6A and 1B, allowed detecting a larger number of leprosy patients when compared to controls. The corresponding peptides expressed by selected phage clones were chemically synthesized. A pilot study was undertaken to assess the use of peptides in skin tests. The intradermal challenge with peptides in animals previously sensitized with Mycobacterium leprae induced a delayed-type hypersensitivity with peptide 5A (2/5 and peptide 1B (1/5. In positive controls, there was a 3/5 reactivity for lepromin and a 4/5 reactivity of the sensitized animals with soluble extract of M. leprae. Conclusions The preliminary data suggest that may be possible to develop reagents with diagnostic potential based on peptide mimotopes selected by phage display using polyclonal human antibodies.

  3. Labelling of HBV-DNA probe using reagent made in China

    International Nuclear Information System (INIS)

    Wang Quanshi

    1991-01-01

    The labelling hepatitis Bvirus DNA (HBV-DNA) probe was studied by using reagent made in China. The results showed that: (1) The dNTPs with high specific activity was necessary for the labelling of nigh specific activity HBV-DNA probe; (2) reaction of labelling HBV-DNA probe was completed in a few minutes; (3) 0.37 MBq 3 H dTTP (specific activity 1.554TBq/mmol) was enough to label 1 μg HBV-DNA and the specific activity of probe reached 3.4 x 10 cpm/μg; (4) 7 MBqα- 32 P dATP (specific activity > 111 TBq/mmol) can label HBV-DNA probe to specific activity 1.35 x 10 cpm/μg. It was concluded that the reagent made in China can be used for the study in molecular biology

  4. Optical Spectra of Candidate International Celestial Reference Frame (ICRF) Flat-spectrum Radio Sources. III

    Energy Technology Data Exchange (ETDEWEB)

    Titov, O.; Stanford, Laura M. [Geoscience Australia, P.O. Box 378, Canberra, ACT 2601 (Australia); Pursimo, T. [Nordic Optical Telescope, Nordic Optical Telescope Apartado 474E-38700 Santa Cruz de La Palma, Santa Cruz de Tenerife (Spain); Johnston, Helen M.; Hunstead, Richard W. [Sydney Institute for Astronomy, School of Physics, University of Sydney, NSW 2006 (Australia); Jauncey, David L. [CSIRO Astronomy and Space Science, ATNF and Mount Stromlo Observatory, Cotter Road, Weston, ACT 2611 (Australia); Zenere, Katrina A., E-mail: oleg.titov@ga.gov.au [School of Physics, University of Sydney, NSW 2006 (Australia)

    2017-04-01

    In extending our spectroscopic program, which targets sources drawn from the International Celestial Reference Frame (ICRF) Catalog, we have obtained spectra for ∼160 compact, flat-spectrum radio sources and determined redshifts for 112 quasars and radio galaxies. A further 14 sources with featureless spectra have been classified as BL Lac objects. Spectra were obtained at three telescopes: the 3.58 m European Southern Observatory New Technology Telescope, and the two 8.2 m Gemini telescopes in Hawaii and Chile. While most of the sources are powerful quasars, a significant fraction of radio galaxies is also included from the list of non-defining ICRF radio sources.

  5. Radiation chemical technology of industrial polymer reagents development

    International Nuclear Information System (INIS)

    Kudaibergenov, S.; Nurkeeva, Z.; Mun, G.; Sigitov, V.; Maltzeva, R.; Petukhov, V.; Tchekushin, A.

    1996-01-01

    The goal of this project is to develop the technology of producing of polymeric reagents from the raw materials of Kazakstan for application in medicine, agriculture, enhanced oil recovery and ecology. To achieve the objectives the next technological lines or operations (Blocks) should be realized: 1. Rectification column and distilling apparatus for purification of monomers and solvents including analytical equipment to control the quality of the final product; 2. Irradiation of reaction mixture by either gamma-irradiation source Co-60; 3. Purification of polymer reagents; 4. Producing of commercial products. It is supposed that the power irradiation devices for producing of hydrogels will be mounted on the research atomic reactor of the Almaty Branch of the Institute of Atomic Energy of the National Nuclear Center. There are high qualification personal which has much experience in radioactive materials operating. Irradiation technologies will provide the low cost of hydrogels, approximately 250-300 US$ per 1 ton. Expected results. One can expect that the realization of this project allows to produce hydrogels in industrial scale to cover partly the requirements of medicine, agriculture, oil industry and ecology

  6. The International Reference Ionosphere: Model Update 2016

    Science.gov (United States)

    Bilitza, Dieter; Altadill, David; Reinisch, Bodo; Galkin, Ivan; Shubin, Valentin; Truhlik, Vladimir

    2016-04-01

    The International Reference Ionosphere (IRI) is recognized as the official standard for the ionosphere (COSPAR, URSI, ISO) and is widely used for a multitude of different applications as evidenced by the many papers in science and engineering journals that acknowledge the use of IRI (e.g., about 11% of all Radio Science papers each year). One of the shortcomings of the model has been the dependence of the F2 peak height modeling on the propagation factor M(3000)F2. With the 2016 version of IRI, two new models will be introduced for hmF2 that were developed directly based on hmF2 measurements by ionosondes [Altadill et al., 2013] and by COSMIC radio occultation [Shubin, 2015], respectively. In addition IRI-2016 will include an improved representation of the ionosphere during the very low solar activities that were reached during the last solar minimum in 2008/2009. This presentation will review these and other improvements that are being implemented with the 2016 version of the IRI model. We will also discuss recent IRI workshops and their findings and results. One of the most exciting new projects is the development of the Real-Time IRI [Galkin et al., 2012]. We will discuss the current status and plans for the future. Altadill, D., S. Magdaleno, J.M. Torta, E. Blanch (2013), Global empirical models of the density peak height and of the equivalent scale height for quiet conditions, Advances in Space Research 52, 1756-1769, doi:10.1016/j.asr.2012.11.018. Galkin, I.A., B.W. Reinisch, X. Huang, and D. Bilitza (2012), Assimilation of GIRO Data into a Real-Time IRI, Radio Science, 47, RS0L07, doi:10.1029/2011RS004952. Shubin V.N. (2015), Global median model of the F2-layer peak height based on ionospheric radio-occultation and ground-based Digisonde observations, Advances in Space Research 56, 916-928, doi:10.1016/j.asr.2015.05.029.

  7. Bio-sample detection on paper-based devices with inkjet printer-sprayed reagents.

    Science.gov (United States)

    Liang, Wun-Hong; Chu, Chien-Hung; Yang, Ruey-Jen

    2015-12-01

    The reagent required for bio-sample detection on paper-based analytical devices is generally introduced manually using a pipette. Such an approach is time-consuming; particularly if a large number of devices are required. Automated methods provide a far more convenient solution for large-scale production, but incur a substantial cost. Accordingly, the present study proposes a low-cost method for the paper-based analytical devices in which the biochemical reagents are sprayed onto the device directly using a modified commercial inkjet printer. The feasibility of the proposed method is demonstrated by performing aspartate aminotransferase (AST) and alanine aminotransferase (ALT) tests using simple two-dimensional (2D) paper-based devices. In both cases, the reaction process is analyzed using an image-processing-based colorimetric method. The experimental results show that for AST detection within the 0-105 U/l concentration range, the optimal observation time is around four minutes, while for ALT detection in the 0-125 U/l concentration range, the optimal observation time is approximately one minute. Finally, for both samples, the detection performance of the sprayed-reagent analytical devices is insensitive to the glucose concentration. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Specific Reagent for Cr(III): Imaging Cellular Uptake of Cr(III) in Hct116 Cells and Theoretical Rationalization.

    Science.gov (United States)

    Ali, Firoj; Saha, Sukdeb; Maity, Arunava; Taye, Nandaraj; Si, Mrinal Kanti; Suresh, E; Ganguly, Bishwajit; Chattopadhyay, Samit; Das, Amitava

    2015-10-15

    A new rhodamine-based reagent (L1), trapped inside the micellar structure of biologically benign Triton-X 100, could be used for specific recognition of Cr(III) in aqueous buffer medium having physiological pH. This visible light excitable reagent on selective binding to Cr(III) resulted in a strong fluorescence turn-on response with a maximum at ∼583 nm and tail of that luminescence band extended until 650 nm, an optical response that is desired for avoiding the cellular autofluorescence. Interference studies confirm that other metal ions do not interfere with the detection process of Cr(III) in aqueous buffer medium having pH 7.2. To examine the nature of binding of Cr(III) to L1, various spectroscopic studies are performed with the model reagent L2, which tend to support Cr(III)-η(2)-olefin π-interactions involving two olefin bonds in molecular probe L1. Computational studies are also performed with another model reagent LM to examine the possibility of such Cr(III)-η(2)-olefin π-interactions. Presumably, polar functional groups of the model reagent LM upon coordination to the Cr(III) center effectively reduce the formal charge on the metal ion and this is further substantiated by results of the theoretical studies. This assembly is found to be cell membrane permeable and shows insignificant toxicity toward live colon cancer cells (Hct116). Confocal laser scanning microscopic studies further revealed that the reagent L1 could be used as an imaging reagent for detection of cellular uptake of Cr(III) in pure aqueous buffer medium by Hct116 cells. Examples of a specific reagent for paramagnetic Cr(III) with luminescence ON response are scanty in the contemporary literature. This ligand design helped us in achieving the turn on response by utilizing the conversion from spirolactam to an acyclic xanthene form on coordination to Cr(III).

  9. Determination оf Optimum Constructive Parameters for Circulating-Reagent Regeneration Sector Apparatus

    Directory of Open Access Journals (Sweden)

    A. M. Sheiko

    2008-01-01

    Full Text Available On the basis of equation analysis for velocity distribution in near filter mudded zone optimal constructional parameters of sector apparatus for circulating-reagent well filter regeneration have been evaluated via angle ratio of forcing and section sectors and number of sectors. The method for determination of sector apparatus length of а selected pump that provides dissolution of mud formation in filter and near filter zone is proposed in the paper. The obtained data would promote upgrading of circulating-reagent water well regeneration technology and it permits to carry out high quality and even rehabilitation of pore space penetration along the full well filter length.

  10. The evaluation of a frame-of-reference training programme for intern psychometrists

    Directory of Open Access Journals (Sweden)

    Gerdi Mulder

    2013-07-01

    Full Text Available Orientation: The use of assessment centres (ACs has drastically increased over the past decade. However, ACs are constantly confronted with the lack of construct validity. One aspect of ACs that could improve the construct validity significantly is that of assessor training. Unfortunately untrained or poorly trained assessors are often used in AC processes. Research purpose: The purpose of this research was to evaluate a frame-of-reference (FOR programme to train intern psychometrists as assessors at an assessment centre. Motivation of study: The role of an assessor is important in an AC; therefore it is vital for an assessor to be able to evaluate and observe candidates’ behaviour adequately. Commencing with this training in a graduate psychometrist programme gives the added benefit of sending skilled psychometrists to the workplace. Research design, approach and method: A quantitative research approach was implemented, utilising a randomised pre-test-post-test comparison group design. Industrial Psychology postgraduate students (N = 22 at a South African university were used and divided into an experimental group (n = 11 and control group (n = 11. Three typical AC simulations were utilised as pre- and post-tests, and the ratings obtained from both groups were statistically analysed to determine the effect of the FOR training programme. Main findings: The data indicated that there was a significant increase in the familiarity of the participants with the one-on-one simulation and the group discussion simulation. Practical/managerial implications: Training intern psychometrists in a FOR programme could assist organisations in the appointment of more competent assessors. Contribution/value-add: To design an assessor training programme using FOR training for intern psychometrists in the South African context, specifically by incorporating this programme into the training programme for Honours students at universities.

  11. Synthesis and characterization of zwitterionic carbon dioxide fixing reagents

    DEFF Research Database (Denmark)

    Mikkelsen, Mette; Jørgensen, Mikkel; Krebs, Frederik C

    2010-01-01

    with 13CO2 labeling and medium pressure NMR. The experiments showed that two of the three reagents were able to form carbamates and thus bind CO2. In addition we investigated this particular class of molecules for the possible formation of neutrally charged spiro compounds and we show that these did...

  12. An internal reference model-based PRF temperature mapping method with Cramer-Rao lower bound noise performance analysis.

    Science.gov (United States)

    Li, Cheng; Pan, Xinyi; Ying, Kui; Zhang, Qiang; An, Jing; Weng, Dehe; Qin, Wen; Li, Kuncheng

    2009-11-01

    The conventional phase difference method for MR thermometry suffers from disturbances caused by the presence of lipid protons, motion-induced error, and field drift. A signal model is presented with multi-echo gradient echo (GRE) sequence using a fat signal as an internal reference to overcome these problems. The internal reference signal model is fit to the water and fat signals by the extended Prony algorithm and the Levenberg-Marquardt algorithm to estimate the chemical shifts between water and fat which contain temperature information. A noise analysis of the signal model was conducted using the Cramer-Rao lower bound to evaluate the noise performance of various algorithms, the effects of imaging parameters, and the influence of the water:fat signal ratio in a sample on the temperature estimate. Comparison of the calculated temperature map and thermocouple temperature measurements shows that the maximum temperature estimation error is 0.614 degrees C, with a standard deviation of 0.06 degrees C, confirming the feasibility of this model-based temperature mapping method. The influence of sample water:fat signal ratio on the accuracy of the temperature estimate is evaluated in a water-fat mixed phantom experiment with an optimal ratio of approximately 0.66:1. (c) 2009 Wiley-Liss, Inc.

  13. The hydrogen sulfide donor, Lawesson's reagent, prevents alendronate-induced gastric damage in rats

    Energy Technology Data Exchange (ETDEWEB)

    Nicolau, L.A.D. [Núcleo de Pesquisa em Produtos Naturais, Departamento de Farmacologia, Universidade Federal do Piauí, Teresina, PI (Brazil); Silva, R.O.; Damasceno, S.R.B.; Carvalho, N.S.; Costa, N.R.D. [Laboratório de Fisiofarmacologia Experimental, Centro de Pesquisa em Biodiversidade e Biotecnologia, Universidade Federal do Piauí, Parnaíba, PI (Brazil); Aragão, K.S. [Laboratório de Farmacologia da Inflamação e do Câncer, Departamento de Farmacologia, Universidade Federal do Ceará, Fortaleza, CE (Brazil); Barbosa, A.L.R. [Núcleo de Pesquisa em Produtos Naturais, Departamento de Farmacologia, Universidade Federal do Piauí, Teresina, PI (Brazil); Laboratório de Fisiofarmacologia Experimental, Centro de Pesquisa em Biodiversidade e Biotecnologia, Universidade Federal do Piauí, Parnaíba, PI (Brazil); Soares, P.M.G.; Souza, M.H.L.P. [Laboratório de Farmacologia da Inflamação e do Câncer, Departamento de Farmacologia, Universidade Federal do Ceará, Fortaleza, CE (Brazil); Medeiros, J.V.R. [Núcleo de Pesquisa em Produtos Naturais, Departamento de Farmacologia, Universidade Federal do Piauí, Teresina, PI (Brazil); Laboratório de Fisiofarmacologia Experimental, Centro de Pesquisa em Biodiversidade e Biotecnologia, Universidade Federal do Piauí, Parnaíba, PI (Brazil)

    2013-08-16

    Our objective was to investigate the protective effect of Lawesson's reagent, an H{sub 2}S donor, against alendronate (ALD)-induced gastric damage in rats. Rats were pretreated with saline or Lawesson's reagent (3, 9, or 27 µmol/kg, po) once daily for 4 days. After 30 min, gastric damage was induced by ALD (30 mg/kg) administration by gavage. On the last day of treatment, the animals were killed 4 h after ALD administration. Gastric lesions were measured using a computer planimetry program, and gastric corpus pieces were assayed for malondialdehyde (MDA), glutathione (GSH), proinflammatory cytokines [tumor necrosis factor (TNF)-α and interleukin (IL)-1β], and myeloperoxidase (MPO). Other groups were pretreated with glibenclamide (5 mg/kg, ip) or with glibenclamide (5 mg/kg, ip)+diazoxide (3 mg/kg, ip). After 1 h, 27 µmol/kg Lawesson's reagent was administered. After 30 min, 30 mg/kg ALD was administered. ALD caused gastric damage (63.35±9.8 mm{sup 2}); increased levels of TNF-α, IL-1β, and MDA (2311±302.3 pg/mL, 901.9±106.2 pg/mL, 121.1±4.3 nmol/g, respectively); increased MPO activity (26.1±3.8 U/mg); and reduced GSH levels (180.3±21.9 µg/g). ALD also increased cystathionine-γ-lyase immunoreactivity in the gastric mucosa. Pretreatment with Lawesson's reagent (27 µmol/kg) attenuated ALD-mediated gastric damage (15.77±5.3 mm{sup 2}); reduced TNF-α, IL-1β, and MDA formation (1502±150.2 pg/mL, 632.3±43.4 pg/mL, 78.4±7.6 nmol/g, respectively); lowered MPO activity (11.7±2.8 U/mg); and increased the level of GSH in the gastric tissue (397.9±40.2 µg/g). Glibenclamide alone reversed the gastric protective effect of Lawesson's reagent. However, glibenclamide plus diazoxide did not alter the effects of Lawesson's reagent. Our results suggest that Lawesson's reagent plays a protective role against ALD-induced gastric damage through mechanisms that depend at least in part on activation of ATP-sensitive potassium (K

  14. Novel Safranin-Tinted Candida rugosa Lipase Nanoconjugates Reagent for Visualizing Latent Fingerprints on Stainless Steel Knives Immersed in a Natural Outdoor Pond

    Directory of Open Access Journals (Sweden)

    Aida Rasyidah Azman

    2018-05-01

    Full Text Available Waterways are popular locations for the disposition of criminal evidence because the recovery of latent fingerprints from such evidence is difficult. Currently, small particle reagent is a method often used to visualize latent fingerprints containing carcinogenic and hazardous compounds. This study proposes an eco-friendly, safranin-tinted Candida rugosa lipase (triacylglycerol ester hydrolysis EC 3.1.1.3 with functionalized carbon nanotubes (CRL-MWCNTS/GA/SAF as an alternative reagent to the small particle reagent. The CRL-MWCNTS/GA/SAF reagent was compared with the small particle reagent to visualize groomed, full fingerprints deposited on stainless steel knives which were immersed in a natural outdoor pond for 30 days. The quality of visualized fingerprints using the new reagent was similar (modified-Centre for Applied Science and Technology grade: 4; p > 0.05 to small particle reagent, even after 15 days of immersion. Despite the slight decrease in quality of visualized fingerprints using the CRL-MWCNTS/GA/SAF on the last three immersion periods, the fingerprints remained forensically identifiable (modified-Centre for Applied Science and Technology grade: 3. The possible chemical interactions that enabled successful visualization is also discussed. Thus, this novel reagent may provide a relatively greener alternative for the visualization of latent fingerprints on immersed non-porous objects.

  15. Microwave-Assisted Organic Synthesis Using Benign Reaction Medium and Reagents

    Science.gov (United States)

    Account of chemical reactions expedited by microwave (MW) exposure of neat reactants for the rapid one-pot assembly of heterocyclic compounds from in situ generated reactive intermediates via enamines or using hypervalent iodine reagents will be described that can be adapted for ...

  16. Comparação de bulas de duas marcas de tiras reagentes utilizadas no exame químico de urina Comparison of product labelings of two marks of reagent strips for the chemical examination of urine

    Directory of Open Access Journals (Sweden)

    Adriana Scotti da Silva Colombeli

    2006-04-01

    Full Text Available INTRODUÇÃO: O exame de urina proporciona informações sobre patologias renais e do trato urinário, bem como algumas moléstias extra-renais. Usualmente o exame químico de urina é feito com tiras reagentes, objetivando tornar a determinação mais rápida, simples e econômica. OBJETIVOS: Comparar bulas de duas marcas de tiras amplamente utilizadas em laboratórios de urinálise (Roche Combur10 Test® UX e Bayer Multistix® 10 SG. MATERIAL E MÉTODO: Compararam-se as bulas quanto aos princípios utilizados nas determinações de pH, proteínas, glicose, cetonas, hemoglobina, bilirrubina, urobilinogênio, nitrito, densidade e leucócitos, além das informações sobre possíveis interferências. RESULTADOS: Foram verificadas diferenças nos reagentes utilizados para detecção dos parâmetros, como é o caso do urobilinogênio (a tira Multistix usa o reagente de Ehrlich, menos específico e mais propenso a interferências analíticas que o sal de diazônio derivado de metoxibenzeno, utilizado na tira Roche; para nitrito, proteína, glicose, bilirrubina e hemoglobina as diferenças foram mais sutis. DISCUSSÃO: Detectou-se diversidade de informações quanto a possíveis interferentes, o que talvez possa ser justificado parcialmente pelas diferenças nos reagentes. Também foram verificadas diferenças nas informações sobre interferências de um idioma para outro, destacando-se a omissão de algumas delas na bula em português. Observou-se grande disparidade na avaliação da intensidade da reação e sua expressão em cruzes, como, por exemplo, no parâmetro glicose, o que pode levar a erros na interpretação do laudo laboratorial. CONCLUSÃO: As observações registradas reforçam a importância de padronizações no exame parcial de urina.BACKGROUND: The urinalysis provides information about renal and urinary diseases, as well as about some extra renal diseases. The chemical examination of urine is done with reagent strips, which allows

  17. Application of cyclic phosphonamide reagents in the total synthesis of natural products and biologically active molecules

    Directory of Open Access Journals (Sweden)

    Thilo Focken

    2014-08-01

    Full Text Available A review of the synthesis of natural products and bioactive compounds adopting phosphonamide anion technology is presented highlighting the utility of phosphonamide reagents in stereocontrolled bond-forming reactions. Methodologies utilizing phosphonamide anions in asymmetric alkylations, Michael additions, olefinations, and cyclopropanations will be summarized, as well as an overview of the synthesis of the employed phosphonamide reagents.

  18. Total Synthesis of Natural Products Using Hypervalent Iodine Reagents

    Directory of Open Access Journals (Sweden)

    Gaetan eMaertens

    2015-01-01

    Full Text Available We present a review of natural product syntheses accomplished in our laboratory during the last five years. Each synthetic route features a phenol dearomatization promoted by an environmentally benign hypervalent iodine reagent. The dearomatizations demonstrate the aromatic ring umpolung concept, and involve stereoselective remodeling of the inert unsaturations of a phenol into a highly functionalized key intermediate that may contain a quaternary carbon center and a prochiral dienone system. Several new oxidative strategies were employed, including transpositions (1,3-alkyl shift and Prins-pinacol, a polycyclization, an ipso rearrangement, and direct nucleophilic additions at the phenol para position. Several alkaloids, heterocyclic compounds, and a polycyclic core have been achieved, including sceletenone (a serotonin reuptake inhibitor, acetylaspidoalbidine (an antitumor agent, fortucine (antiviral and antitumor, erysotramidine (curare-like effect, platensimycin (an antibiotic, and the main core of a kaurane diterpene (immunosuppressive agent and stimulator of apoptosis. These concise and in some cases enantioselective syntheses effectively demonstrate the importance of hypervalent iodine reagents in the total synthesis of bioactive natural products.

  19. Evaluation of a portable urinary pH meter and reagent strips.

    Science.gov (United States)

    De Coninck, Vincent; Keller, Etienne Xavier; Rodríguez-Monsalve, María; Haymann, Jean-Philippe; Doizi, Steeve; Traxer, Olivier

    2018-04-27

    To evaluate a portable electronic pH meter and to put its accuracy in perspective with reagent strips read by a layperson, a healthcare professional and an electronic reading device. Based on a pre-analysis on 20 patients, a sample size of 77 urine aliquots from healthy volunteers was necessary to obtain sufficient study power. Measurements of urinary pH were obtained by use of reagent strips, a portable pH meter and a laboratory pH meter (gold standard). Reagents strips were read by a professional experienced in interpreting strips, a layperson, and an electronic strip reader. The mean matched pair difference between measurement methods was analyzed by the paired t-test. The degree of correlation and agreement were evaluated by the Pearson's correlation coefficient and Bland-Altman plots, respectively. The mean matched pair difference between the gold standard and all other pH measurement methods was the smallest with the portable electronic pH meter (bias 0.01, 95% CI -0.07 to 0.08; p=0.89), followed by strips read by a professional (bias -0.09, 95% CI -0.21 to 0.02; p=0.10), layperson (bias -0.17, 95% CI -0.31 to -0.04; p=0.015) and electronic strip reader (bias -0.29, 95% CI -0.41 to -0.16; pmeter achieved the highest Pearson's correlation coefficient and narrowest 95% limits of agreement, followed by strip interpretation by a professional, the electronic strip reader and the layperson. In order to quantify the ability of pH measurement methods to correctly classify values within a predefined urinary pH target range, we performed classification tests for several stones. The portable electronic pH meter outperformed all other measurement methods for negative predictive values. Findings of the current study support that the portable electronic pH meter is a reliable pH measuring device. It seems to be more accurate compared to reagent strips readings.

  20. satl based lesson for teaching grignard reagents in synthetic organic

    African Journals Online (AJOL)

    IICBA01

    Traditionally, Grignard reagent has been very vital component of such synthetic ... knowledge, the systemic methodology of teaching and learning is the key point. Chemistry is ... chosen in particular to enlighten the students about effectiveness of systemic approach to .... Lectures through Systemic Approach to Teaching and.

  1. Rapid diagnosis of schistosomiasis in Yemen using a simple questionnaire and urine reagent strips.

    Science.gov (United States)

    Bassiouny, H K; Hasab, A A; El-Nimr, N A; Al-Shibani, L A; Al-Waleedi, A A

    2014-05-01

    Schistosomiasis ranks second to malaria in terms of socioeconomic and public health importance in Yemen. This study assessed the validity of a morbidity questionnaire and urine reagent strips as a rapid tool for screening schoolchildren for urinary schistosomiasis as compared with the presence of eggs in urine as the gold-standard parasitological diagnosis. The study examined urine samples and interviewed 696 children (mean age 12.5 years) attending a primary-preparatory school in south Yemen. Urinary schistosomiasis was confirmed in 126 (18.1%) children. Diagnostic performance was poor for 2 items in the morbidity questionnaire (self-reported history of previous infection and self-reported history of antischistosomal treatment). However, self-reported dysuria, self-reported haematuria in the questionnaire and microhaematuria by reagent strips (alone or with macrohaematuria) revealed good diagnostic performance. The results indicated that reagent strips are a valid method for detection of microhaematuria for identifying individuals and communities infected with Schistosoma haematobium.

  2. The development of a neutralizing amines based reagent for maintaining the water chemistry for medium and high pressures steam boilers

    Science.gov (United States)

    Butakova, M. V.; Orlov, K. A.; Guseva, O. V.

    2017-11-01

    An overview of the development for neutralizing amine based reagent for water chemistry of steam boilers for medium and high pressures was given. Total values of the neutralization constants and the distribution coefficients of the compositions selected as a main criteria for reagent composition. Experimental results of using this new reagent for water chemistry in HRSG of power plant in oil-production company are discussed.

  3. The Internal/External Frame of Reference Model of Self-Concept and Achievement Relations: Age-Cohort and Cross-Cultural Differences

    Science.gov (United States)

    Marsh, Herbert W.; Abduljabbar, Adel Salah; Parker, Philip D.; Morin, Alexandre J. S.; Abdelfattah, Faisal; Nagengast, Benjamin; Möller, Jens; Abu-Hilal, Maher M.

    2015-01-01

    The internal/external frame of reference (I/E) model and dimensional comparison theory posit paradoxical relations between achievement (ACH) and self-concept (SC) in mathematics (M) and verbal (V) domains; ACH in each domain positively affects SC in the matching domain (e.g., MACH to MSC) but negatively in the nonmatching domain (e.g., MACH to…

  4. Influence of reagents mixture density on the radiation-thermal synthesis of lithium-zinc ferrites

    Science.gov (United States)

    Surzhikov, A. P.; Lysenko, E. N.; Vlasov, V. A.; Malyshev, A. V.; Korobeynikov, M. V.; Mikhailenko, M. A.

    2017-01-01

    Influence of Li2CO3-ZnO-Fe2O3 powder reagents mixture density on the synthesis efficiency of lithium-zinc ferrites in the conditions of thermal heating or pulsed electron beam heating was studied by X-Ray diffraction and magnetization analysis. The results showed that the including a compaction of powder reagents mixture in ferrite synthesis leads to an increase in concentration of the spinel phase and decrease in initial components content in lithium-substituted ferrites synthesized by thermal or radiation-thermal heating.

  5. A New Achiral Linker Reagent for the Incorporation of Multiple Amino Groups Into Oligonucleotides

    DEFF Research Database (Denmark)

    1997-01-01

    The present invention relates to a new functionalized achiral linker reagent for incorporating multiple primary amino groups or reporter groups into oligonucleotides following the phosphoramidite methodology. It is possible to substitute any ribodeoxynucleotide, deoxynucleotide, or nucleotide......-oxyl-2,2,5,5-tetramethylpyrrolidine), TEMPO (N-oxyl-2,2,6,6-tetramethylpiperidine), dinitrophenyl, texas red, tetramethyl rhodamine, 7-nitrobenzo-2-oxa-1-diazole (NBD), or pyrene. The present invention also relates to a solid phase support, e.g. a Controlled Pore Glass (CPG), immobilized linker reagent...

  6. The Principle of Integration in International Sustainable Development Law (ISDL with Reference to the Biological Weapons Convention (BWC

    Directory of Open Access Journals (Sweden)

    Marina Abdul Majid

    2016-02-01

    Full Text Available The Biological Weapons Convention (BWC does not explicitly refer to sustainable development despite the fact that other United Nations (UN disarmament documents prescribe that international environmental law principles and sustainable development be considered among arms control agreements. This study’s objective is to utilize the principle of integration’s three components of environmental, economic, and social development, as found in the International Sustainable Development Law (ISDL from the New Delhi Declaration (Delhi Declaration of Principles of International Law Relating to Sustainable Development, in order to evaluate whether the BWC contains such components; thereby, making it possible for the BWC to contribute to sustainable development. The methodology of this study is necessarily qualitative, given that it is a socio-legal research that relies on international agreements such as the BWC, declarations, resolutions, plans of implementation, other non-binding documents of the UN, and secondary resources—all of which are analyzed through a document analysis. The results show that the BWC addresses the environment (Article II, prohibits transfers relating to export controls, international trade, and economic development (Article III, while at the same time, covering social development concerns, health, and diseases that make up the international social law (Article X. Since the BWC is found to be capable of contributing to sustainable development, it is concluded that ISDL cannot be restricted to international environmental, economic, and social law, but should be expanded to include international arms control law.

  7. Evaluation of Directions for Use Compatibility Between Different Brands Strips Urine Reagent

    Directory of Open Access Journals (Sweden)

    Guilherme de Oliveira Cezar

    2012-06-01

    Full Text Available Through the urine test we can measure kidney function and identify pathologies of the urinary tract. The urine test strips are a fast, easy and increasingly used method of analysis. It is extremely important to check compatibility between the different brands assuring a better understanding of the diagnosis. We compared the package inserts of eight different brands of urine test strips and the reagents used in the urinary determination, besides information concerning the detection of limit ranges, reading intervals and possible interferences. A comparison of the leaflets showed differences among them. Concerning the reagents used, in general, all brands use similar ones but in different quantities. The patient information leaflets have several interferences, but it was observed that some brands do not mention the interferences that are mentioned in other brands. As for the legends of semiquantitative measurements, most brands do not include this information on the product leaflet. Among the brands that could be analyzed with this parameter was observed that the analytes glucose, bilirubin, ketones and blood did not have the same correlation between concentration and label brands. We stress the importance of ensuring a greater standardization of the information contained in the leaflets of the reagent strips.

  8. Chemical bonding and the equilibrium composition of Grignard reagents in ethereal solutions.

    Science.gov (United States)

    Henriques, André M; Barbosa, André G H

    2011-11-10

    A thorough analysis of the electronic structure and thermodynamic aspects of Grignard reagents and its associated equilibrium composition in ethereal solutions is performed. Considering methylmagnesium halides containing fluorine, chlorine, and bromine, we studied the neutral, charged, and radical species associated with their chemical equilibrium in solution. The ethereal solvents considered, tetrahydrofuran (THF) and ethyl ether (Et(2)O), were modeled using the polarizable continuum model (PCM) and also by explicit coordination to the Mg atoms in a cluster. The chemical bonding of the species that constitute the Grignard reagent is analyzed in detail with generalized valence bond (GVB) wave functions. Equilibrium constants were calculated with the DFT/M06 functional and GVB wave functions, yielding similar results. According to our calculations and existing kinetic and electrochemical evidence, the species R(•), R(-), (•)MgX, and RMgX(2)(-) must be present in low concentration in the equilibrium. We conclude that depending on the halogen, a different route must be followed to produce the relevant equilibrium species in each case. Chloride and bromide must preferably follow a "radical-based" pathway, and fluoride must follow a "carbanionic-based" pathway. These different mechanisms are contrasted against the available experimental results and are proven to be consistent with the existing thermodynamic data on the Grignard reagent equilibria.

  9. Measurement of the enzymes lactate dehydrogenase and creatine kinase using reflectance spectroscopy and reagent strips.

    OpenAIRE

    Stevens, J F; Tsang, W; Newall, R G

    1983-01-01

    Two new methods for the assay of total activities of lactate dehydrogenase and creatine kinase are described, in which the enzyme activities are measured from a solid-state reagent strip during a kinetic reaction, the reaction being monitored in the ultra-violet region of the spectrum by reflectance spectroscopy. The performances of these methods are evaluated, and compared to conventional "wet" chemistry methods. The solid-phase reagent methods demonstrated precision and accuracy acceptable ...

  10. Reagent' sets for the concentration of sup(99m)Tc and sup(113m)In

    International Nuclear Information System (INIS)

    Bianco de Salas, G.N.; Arciprete, J.; Mitta, A.E.A.

    1976-10-01

    A simple technique for the concentration of the eluates from 99 Mo/sup(99m)Tc and 113 Sn/sup(113m)In generators is described. The reagents' sets provided by the C.N.E.A. for the labelling of different radiopharmaceuticals can be used by only reducing their volumes proportionally. Both concentration techniques for Tc-99m and In-113m will be supplied to users as reagents' sets. (author) [es

  11. Inactivation of Escherichia coli glycerol kinase by 5'-[p-(fluorosulfonyl)benzoyl]adenosine: protection by the hydrolyzed reagent

    International Nuclear Information System (INIS)

    Pettigrew, D.W.

    1987-01-01

    Incubation of Escherichia coli glycerol kinase with 5'-[p-(fluorosulfonyl)benzoyl]adenosine (FSO 2 BzAdo) at pH 8.0 and 25 0 C results in the loss of enzyme activity, which is not restored by the addition of β-mercaptoethanol or dithiothreitol. The FSO 2 BzAdo concentration dependence of the inactivation kinetics is described by a mechanism that includes the equilibrium binding of the reagent to the enzyme prior to a first-order inactivation reaction in addition to effects of reagent hydrolysis. The hydrolysis of the reagent has two effects on the observed kinetics. The first effect is deviation from pseudo-first-order kinetic behavior due to depletion of the reagent. The second effect is the novel protection of the enzyme from inactivation due to binding of the sulfonate hydrolysis product. Determinations of the reaction stoichiometry with 3 H-labeled FSO 2 BzAdo show that the inactivation is associated with the covalent incorporation of 1.08 mol of reagent/mol of enzyme subunit. Ligand protection experiments show that ATP, AMP, dAMP, NADH, 5'-adenylyl imidodiphosphate, and the sulfonate hydrolysis product of FSO 2 BzAdo provide protection from inactivation. The protection obtained with ATMP is not dependent on Mg 2+ . The results are consistent with modification by FSO 2 BzAdo of a single adenine nucleotide binding site per enzyme subunit

  12. Identification of valid reference genes for the normalization of RT-qPCR expression studies in human breast cancer cell lines treated with and without transient transfection.

    Directory of Open Access Journals (Sweden)

    Lin-Lin Liu

    Full Text Available Reverse transcription-quantitative polymerase chain reaction (RT-qPCR is a powerful technique for examining gene expression changes during tumorigenesis. Target gene expression is generally normalized by a stably expressed endogenous reference gene; however, reference gene expression may differ among tissues under various circumstances. Because no valid reference genes have been documented for human breast cancer cell lines containing different cancer subtypes treated with transient transfection, we identified appropriate and reliable reference genes from thirteen candidates in a panel of 10 normal and cancerous human breast cell lines under experimental conditions with/without transfection treatments with two transfection reagents. Reference gene expression stability was calculated using four algorithms (geNorm, NormFinder, BestKeeper and comparative delta Ct, and the recommended comprehensive ranking was provided using geometric means of the ranking values using the RefFinder tool. GeNorm analysis revealed that two reference genes should be sufficient for all cases in this study. A stability analysis suggests that 18S rRNA-ACTB is the best reference gene combination across all cell lines; ACTB-GAPDH is best for basal breast cancer cell lines; and HSPCB-ACTB is best for ER+ breast cancer cells. After transfection, the stability ranking of the reference gene fluctuated, especially with Lipofectamine 2000 transfection reagent in two subtypes of basal and ER+ breast cell lines. Comparisons of relative target gene (HER2 expression revealed different expressional patterns depending on the reference genes used for normalization. We suggest that identifying the most stable and suitable reference genes is critical for studying specific cell lines under certain circumstances.

  13. Evaluation of Tropaeolin 000-1 as a Colorimetric Reagent for Assay ...

    African Journals Online (AJOL)

    for Assay of Duloxetine and Escitalopram in Solid Dosage ... Purpose: To explore the application of tropaeolin 000-1 reagent for the rapid, ..... The effects of placebo interference testing are ... oppositely charged TL and TO ions form a stable.

  14. Avaliação do desempenho dos reagentes do tempo de tromboplastina parcial ativada utilizados para detectar o anticoagulante lúpico Assessment of the performance of reagents of activated partial thromboplastin time used to detect the lupus anticoagulant

    Directory of Open Access Journals (Sweden)

    Fernanda Chiuso

    2005-06-01

    Full Text Available INTRODUÇÃO: O anticoagulante lúpico é uma imunoglobulina pertencente à família dos anticorpos antifosfolípides. A sua ação in vitro é interferir nos testes de coagulação dependentes de fosfolípides. O tempo de tromboplastina parcial ativada (TTPA é um teste utilizado como screening na pesquisa do anticoagulante lúpico. Os reagentes utilizados neste teste apresentam grandes variações quanto à sensibilidade. OBJETIVO: Avaliar o desempenho dos reagentes do TTPA e detectar a presença do anticoagulante lúpico através de diferentes testes da coagulação. MATERIAL E MÉTODO: A pesquisa do anticoagulante lúpico foi realizada em 50 amostras plasmáticas de pacientes do sexo feminino através dos testes do TTPA, do tempo de coagulação do caulim (TCC, do tempo de tromboplastina parcial ativada diluída (TTPAd e do tempo do veneno da víbora de Russel diluído (TVVRd. Três cefalinas comerciais foram avaliadas pelos testes do TTPA e do TTPAd. Na comparação entre os reagentes estudados foi aplicado o cálculo do intervalo de confiança (95%. RESULTADOS: Os três reagentes avaliados apresentaram boa concordância e os métodos utilizados responderam bem à pesquisa do anticoagulante lúpico. DISCUSSÃO E CONCLUSÃO: As três cefalinas comerciais avaliadas podem ser utilizadas na rotina laboratorial para a pesquisa do anticoagulante lúpico.INTRODUCTION: The lupus anticoagulant is an immunoglobin which belongs to the antiphospholid antibodies family. Its in vitro function is to interfere with coagulation tests that are dependent on phospholipids. The activated partial thromboplastin time (APTT is a test used as screening on lupus anticoagulant research. Reagents used in this test demonstrate wide sensitivity ranges. OBJECTIVE: To assess the performance of APTT reagents and detect the presence of lupus anticoagulant through various coagulation tests. MATERIAL AND METHOD: The lupus anticoagulant research was performed in plasma from 50

  15. Study of effect of slime processed by ultrasonic on flotation reagent

    Energy Technology Data Exchange (ETDEWEB)

    Kang, W.; Wang, H.; Hu, J. [Heilongjiang Institute of Science and Technology, Harbin (China)

    2006-12-15

    The changes of wetting heat, oil film thickness, contact angle and absorptive capacity of slime and kerosene before and after ultrasonic treatment were studied by Setaram calorimeter, DCAT21 gauge and a light meter. Batch flotation tests were made. The results show that: the wetting heat from slime and kerosene increases after ultrasonic treatment by 45.85%; the average oil film thickness is reduced by 38.84%; the contact angle of slime and kerosene decreases by 33.56{sup o}; and the absorptive capacity of slime in kerosene decreases by 30.40%. The consumption of flotation reagent after ultrasonic treatment was reduced by 75% while the yield of clean coal was the same. The study shows that ultrasonic treatment decreases the consumption of reagent and increases the efficiency and selectivity of flotation. 8 refs., 3 figs., 4 tabs.

  16. Desalting Protein Ions in Native Mass Spectrometry Using Supercharging Reagents

    Science.gov (United States)

    Cassou, Catherine A.; Williams, Evan R.

    2014-01-01

    Effects of the supercharging reagents m-NBA and sulfolane on sodium ion adduction to protein ions formed using native mass spectrometry were investigated. There is extensive sodium adduction on protein ions formed by electrospray ionization from aqueous solutions containing millimolar concentrations of NaCl, which can lower sensitivity by distributing the signal of a given charge state over multiple adducted ions and can reduce mass measuring accuracy for large proteins and non-covalent complexes for which individual adducts cannot be resolved. The average number of sodium ions adducted to the most abundant ion formed from ten small (8.6–29 kDa) proteins for which adducts can be resolved is reduced by 58% or 80% on average, respectively, when 1.5% m-NBA or 2.5% sulfolane are added to aqueous solutions containing sodium compared to without the supercharging reagent. Sulfolane is more effective than m-NBA at reducing sodium ion adduction and at preserving non-covalent protein-ligand and protein-protein interactions. Desalting with 2.5% sulfolane enables detection of several glycosylated forms of 79.7 kDa holo-transferrin and NADH bound to the 146 kDa homotetramer LDH, which are otherwise unresolved due to peak broadening from extensive sodium adduction. Although sulfolane is more effective than m-NBA at protein ion desalting, m-NBA reduces salt clusters at high m/z and can increase the signal-to-noise ratios of protein ions by reducing chemical noise. Desalting is likely a result of these supercharging reagents binding sodium ions in solution, thereby reducing the sodium available to adduct to protein ions. PMID:25133273

  17. Enhanced electrocatalytic CO2 reduction via field-induced reagent concentration

    Science.gov (United States)

    Liu, Min; Pang, Yuanjie; Zhang, Bo; de Luna, Phil; Voznyy, Oleksandr; Xu, Jixian; Zheng, Xueli; Dinh, Cao Thang; Fan, Fengjia; Cao, Changhong; de Arquer, F. Pelayo García; Safaei, Tina Saberi; Mepham, Adam; Klinkova, Anna; Kumacheva, Eugenia; Filleter, Tobin; Sinton, David; Kelley, Shana O.; Sargent, Edward H.

    2016-09-01

    Electrochemical reduction of carbon dioxide (CO2) to carbon monoxide (CO) is the first step in the synthesis of more complex carbon-based fuels and feedstocks using renewable electricity. Unfortunately, the reaction suffers from slow kinetics owing to the low local concentration of CO2 surrounding typical CO2 reduction reaction catalysts. Alkali metal cations are known to overcome this limitation through non-covalent interactions with adsorbed reagent species, but the effect is restricted by the solubility of relevant salts. Large applied electrode potentials can also enhance CO2 adsorption, but this comes at the cost of increased hydrogen (H2) evolution. Here we report that nanostructured electrodes produce, at low applied overpotentials, local high electric fields that concentrate electrolyte cations, which in turn leads to a high local concentration of CO2 close to the active CO2 reduction reaction surface. Simulations reveal tenfold higher electric fields associated with metallic nanometre-sized tips compared to quasi-planar electrode regions, and measurements using gold nanoneedles confirm a field-induced reagent concentration that enables the CO2 reduction reaction to proceed with a geometric current density for CO of 22 milliamperes per square centimetre at -0.35 volts (overpotential of 0.24 volts). This performance surpasses by an order of magnitude the performance of the best gold nanorods, nanoparticles and oxide-derived noble metal catalysts. Similarly designed palladium nanoneedle electrocatalysts produce formate with a Faradaic efficiency of more than 90 per cent and an unprecedented geometric current density for formate of 10 milliamperes per square centimetre at -0.2 volts, demonstrating the wider applicability of the field-induced reagent concentration concept.

  18. Pre-storage of gelified reagents in a lab-on-a-foil system for rapid nucleic acid analysis

    DEFF Research Database (Denmark)

    Yi, Sun; Høgberg, Jonas; Christine, Thanner

    2013-01-01

    Reagent pre-storage in a microfluidic chip can enhance operator convenience, simplify the system design, reduce the cost of storage and shipment, and avoid the risk of cross-contamination. Although dry reagents have long been used in lateral flow immunoassays, they have rarely been used for nucle...... for fast and cost-effective POC analysis....

  19. Biomedical Engineering Desk Reference

    CERN Document Server

    Ratner, Buddy D; Schoen, Frederick J; Lemons, Jack E; Dyro, Joseph; Martinsen, Orjan G; Kyle, Richard; Preim, Bernhard; Bartz, Dirk; Grimnes, Sverre; Vallero, Daniel; Semmlow, John; Murray, W Bosseau; Perez, Reinaldo; Bankman, Isaac; Dunn, Stanley; Ikada, Yoshito; Moghe, Prabhas V; Constantinides, Alkis

    2009-01-01

    A one-stop Desk Reference, for Biomedical Engineers involved in the ever expanding and very fast moving area; this is a book that will not gather dust on the shelf. It brings together the essential professional reference content from leading international contributors in the biomedical engineering field. Material covers a broad range of topics including: Biomechanics and Biomaterials; Tissue Engineering; and Biosignal Processing* A hard-working desk reference providing all the essential material needed by biomedical and clinical engineers on a day-to-day basis * Fundamentals, key techniques,

  20. Microfluidics in the selection of affinity reagents for the detection of cancer: paving a way towards future diagnostics.

    Science.gov (United States)

    Hung, Lien-Yu; Wang, Chih-Hung; Fu, Chien-Yu; Gopinathan, Priya; Lee, Gwo-Bin

    2016-08-07

    Microfluidic technologies have miniaturized a variety of biomedical applications, and these chip-based systems have several significant advantages over their large-scale counterparts. Recently, this technology has been used for automating labor-intensive and time-consuming screening processes, whereby affinity reagents, including aptamers, peptides, antibodies, polysaccharides, glycoproteins, and a variety of small molecules, are used to probe for molecular biomarkers. When compared to conventional methods, the microfluidic approaches are faster, more compact, require considerably smaller quantities of samples and reagents, and can be automated. Furthermore, they allow for more precise control of reaction conditions (e.g., pH, temperature, and shearing forces) such that more efficient screening can be performed. A variety of affinity reagents for targeting cancer cells or cancer biomarkers are now available and will likely replace conventional antibodies. In this review article, the selection of affinity reagents for cancer cells or cancer biomarkers on microfluidic platforms is reviewed with the aim of highlighting the utility of such approaches in cancer diagnostics.

  1. High-performance reagent modes for flotation recovery of platiniferous copper and nickel sulfides from hard-to-beneficiate ores

    Science.gov (United States)

    Matveeva, T. N.; Chanturiya, V. A.

    2017-07-01

    The paper presents the results of the recent research performed in IPKON Russian Academy of Sciences that deals with development and substantiation of new selective reagents for effective flotation recovery of non-ferrous and noble metals from refractory ores. The choice and development of new selective reagents PTTC, OPDTC, modified butylxanthate (BXm) and modified diethyl-dithiocarbamate (DEDTCm) to float platiniferous copper and nickel sulfide minerals from hard-to-beneficiate ores is substantiated. The mechanism of reagents adsorption and regulation of minerals floatability is discussed. The study of reagent modes indicates that by combining PTTC with the modified xanthate results in 6 - 7 % increase in the recovery of copper, nickel and PGM in the flotation of the low-sulfide platiniferous Cu-Ni ore from the Fedorovo-Panskoye deposit. The substitution of OPDTC for BX makes it possible to increase recovery of Pt by 13 %, Pd by 9 % and 2 - 4 times the noble metal content in the flotation concentrate.

  2. Effect of reference loads on fracture mechanics analysis of surface cracked pipe based on reference stress method

    International Nuclear Information System (INIS)

    Shim, Do Jun; Son, Beom Goo; Kim, Young Jin; Kim, Yun Jae

    2004-01-01

    To investigate relevance of the definition of the reference stress to estimate J and C * for surface crack problems, this paper compares FE J and C * results for surface cracked pipes with those estimated according to the reference stress approach using various definitions of the reference stress. Pipes with part circumferential inner surface crack and finite internal axial crack are considered, subject to internal pressure and global bending. The crack depth and aspect ratio are systematically varied. The reference stress is defined in four different ways using (I) the local limit load, (II) the global limit load, (III) the global limit load determined from the FE limit analysis, and (IV) the optimised reference load. It is found that the reference stress based on the local limit load gives overall excessively conservative estimates of J and C * . Use of the global limit load clearly reduces the conservatism, compared to that of the local limit load, although it can provide sometimes non-conservative estimates of J and C * . The use of the FE global limit load gives overall non-conservative estimates of J and C * . The reference stress based on the optimised reference load gives overall accurate estimates of J and C * , compared to other definitions of the reference stress. Based on the present finding, general guidance on the choice of the reference stress for surface crack problems is given

  3. Prevalence of thinness in children and adolescents in the Seychelles: comparison of two international growth references.

    Science.gov (United States)

    Bovet, Pascal; Kizirian, Nathalie; Madeleine, George; Blössner, Monika; Chiolero, Arnaud

    2011-06-09

    Thinness in children and adolescents is largely under studied, a contrast with abundant literature on under-nutrition in infants and on overweight in children and adolescents. The aim of this study is to compare the prevalence of thinness using two recently developed growth references, among children and adolescents living in the Seychelles, an economically rapidly developing country in the African region. Weight and height were measured every year in all children of 4 grades (age range: 5 to 16 years) of all schools in the Seychelles as part of a routine school-based surveillance program. In this study we used data collected in 16,672 boys and 16,668 girls examined from 1998 to 2004. Thinness was estimated according to two growth references: i) an international survey (IS), defining three grades of thinness corresponding to a BMI of 18.5, 17.0 and 16.0 kg/m2 at age 18 and ii) the WHO reference, defined here as three categories of thinness (-1, -2 and -3 SD of BMI for age) with the second and third named "thinness" and "severe thinness", respectively. The prevalence of thinness was 21.4%, 6.4% and 2.0% based on the three IS cut-offs and 27.7%, 6.7% and 1.2% based on the WHO cut-offs. The prevalence of thinness categories tended to decrease according to age for both sexes for the IS reference and among girls for the WHO reference. The prevalence of the first category of thinness was larger with the WHO cut-offs than with the IS cut-offs while the prevalence of thinness of "grade 2" and thinness of "grade 3" (IS cut-offs) was similar to the prevalence of "thinness" and "severe thinness" (WHO cut-offs), respectively.

  4. Prevalence of thinness in children and adolescents in the Seychelles: comparison of two international growth references

    Directory of Open Access Journals (Sweden)

    Madeleine George

    2011-06-01

    Full Text Available Abstract Background Thinness in children and adolescents is largely under studied, a contrast with abundant literature on under-nutrition in infants and on overweight in children and adolescents. The aim of this study is to compare the prevalence of thinness using two recently developed growth references, among children and adolescents living in the Seychelles, an economically rapidly developing country in the African region. Methods Weight and height were measured every year in all children of 4 grades (age range: 5 to 16 years of all schools in the Seychelles as part of a routine school-based surveillance program. In this study we used data collected in 16,672 boys and 16,668 girls examined from 1998 to 2004. Thinness was estimated according to two growth references: i an international survey (IS, defining three grades of thinness corresponding to a BMI of 18.5, 17.0 and 16.0 kg/m2 at age 18 and ii the WHO reference, defined here as three categories of thinness (-1, -2 and -3 SD of BMI for age with the second and third named "thinness" and "severe thinness", respectively. Results The prevalence of thinness was 21.4%, 6.4% and 2.0% based on the three IS cut-offs and 27.7%, 6.7% and 1.2% based on the WHO cut-offs. The prevalence of thinness categories tended to decrease according to age for both sexes for the IS reference and among girls for the WHO reference. Conclusion The prevalence of the first category of thinness was larger with the WHO cut-offs than with the IS cut-offs while the prevalence of thinness of "grade 2" and thinness of "grade 3" (IS cut-offs was similar to the prevalence of "thinness" and "severe thinness" (WHO cut-offs, respectively.

  5. IAEA biological reference materials

    International Nuclear Information System (INIS)

    Parr, R.M.; Schelenz, R.; Ballestra, S.

    1988-01-01

    The Analytical Quality Control Services programme of the IAEA encompasses a wide variety of intercomparisons and reference materials. This paper reviews only those aspects of the subject having to do with biological reference materials. The 1988 programme foresees 13 new intercomparison exercises, one for major, minor and trace elements, five for radionuclides, and seven for stable isotopes. Twenty-two natural matrix biological reference materials are available: twelve for major, minor and trace elements, six for radionuclides, and four for chlorinated hydrocarbons. Seven new intercomparisons and reference materials are in preparation or under active consideration. Guidelines on the correct use of reference materials are being prepared for publication in 1989 in consultation with other major international producers and users of biological reference materials. The IAEA database on available reference materials is being updated and expanded in scope, and a new publication is planned for 1989. (orig.)

  6. International Longitudinal Paediatric Reference Standards for Bone Mineral Content

    Science.gov (United States)

    Baxter-Jones, Adam DG; McKay, Heather; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don

    2014-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women’s Health Study (n=112) and Stanford’s Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement in predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (P accrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. Similar findings were found for PF and FN. Female models for all sites were similar with age, height and weight all independent significant predictors of BMC accrual (P accounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in paediatrics we recommend standards that are sex, age, size and ethnic specific. PMID:19854308

  7. International longitudinal pediatric reference standards for bone mineral content.

    Science.gov (United States)

    Baxter-Jones, Adam D G; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don; McKay, Heather

    2010-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site-specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women's Health Study (n=112) and Stanford's Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement between predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (Paccrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. We report similar findings for the PF and FN. Models for females for all sites were similar with age, height and weight as independent significant predictors of BMC accrual (Paccounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in pediatrics we recommend standards that are sex, age, size and ethnic specific. Copyright (c) 2009 Elsevier Inc. All rights reserved.

  8. Tunable, Quantitative Fenton-RAFT Polymerization via Metered Reagent Addition.

    Science.gov (United States)

    Nothling, Mitchell D; McKenzie, Thomas G; Reyhani, Amin; Qiao, Greg G

    2018-05-10

    A continuous supply of radical species is a key requirement for activating chain growth and accessing quantitative monomer conversions in reversible addition-fragmentation chain transfer (RAFT) polymerization. In Fenton-RAFT, activation is provided by hydroxyl radicals, whose indiscriminate reactivity and short-lived nature poses a challenge to accessing extended polymerization times and quantitative monomer conversions. Here, an alternative Fenton-RAFT procedure is presented, whereby radical generation can be finely controlled via metered dosing of a component of the Fenton redox reaction (H 2 O 2 ) using an external pumping system. By limiting the instantaneous flux of radicals and ensuring sustained radical generation over tunable time periods, metered reagent addition reduces unwanted radical "wasting" reactions and provides access to consistent quantitative monomer conversions with high chain-end fidelity. Fine tuning of radical concentration during polymerization is achieved simply via adjustment of reagent dose rate, offering significant potential for automation. This modular strategy holds promise for extending traditional RAFT initiation toward more tightly regulated radical concentration profiles and affords excellent prospects for the automation of Fenton-RAFT polymerization. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. The influence of reagent type on the kinetics of ultrafine coal flotation

    Science.gov (United States)

    Read, R.B.; Camp, L.R.; Summers, M.S.; Rapp, D.M.

    1989-01-01

    A kinetic study has been conducted to determine the influence of reagent type on flotation rates of ultrafine coal. Two ultrafine coal samples, the Illinois No. 5 (Springfield) and Pittsburgh No. 8, have been evaluated with various reagent types in order to derive the rate constants for coal (kc), ash (ka), and pyrite (kc). The reagents used in the study include anionic surfactants, anionic surfactant-alcohol mixtures, and frothing alcohols. In general, the surfactant-alcohol mixtures tend to float ultrafine coal at a rate three to four times faster than either pure alcohols or pure anionic surfactants. Pine oil, a mixture of terpene alcohols and hydrocarbons, was an exception to this finding; it exhibited higher rate constants than the pure aliphatic alcohols or other pure anionic surfactants studied; this may be explained by the fact that the sample of pine oil used (70% alpha-terpineol) acted as a frother/collector system similar to alcohol/kerosene. The separation efficiencies of ash and pyrite from coal, as evidenced by the ratios of kc/ka or kc/kp, tend to indicate, however, that commercially available surfactant-alcohol mixtures are not as selective as pure alcohols such as 2-ethyl-1-hexanol or methylisobutylcarbinol. Some distinct differences in various rate constants, or their ratios, were noted between the two coals studied, and are possibly attributable to surface chemistry effects. ?? 1989.

  10. Assessment and identification of some novel NOx reducing reagents for SNCR process

    International Nuclear Information System (INIS)

    Mahmood, A.; Javed, M.T.; Irfan, N.; Hamid, A. and K.; Waheed, K.

    2009-01-01

    Nitrogen oxides (NOx) are one of the most hazardous air pollutants arising from the combustion processes. Because of the implementation of strict emission limits many NOx removal technologies have been developed. In the present work post combustion NOx removal technique that is Selective Non-Catalytic Reduction (SNCR) has been investigated in a pilot scale 150 kW combustion rig facility. Investigation has been performed using some novel NOx reducing reagents like urea, ammonium carbonate and mixture of their 50%-50% aqueous solution within the temperature range of 700 to 1200 deg. C., at 1.1% excess oxygen and background NOx level of 500 ppm. The effects of these reagents were determined in term of their temperature characteristics and molar ratio. Among the reducing reagents used urea solution gave the highest NOx removal efficiency (81%) and was attractive due to its superior high temperature (1000 to 1150 deg. C) performance, ammonium carbonate was more effective at lower temperature range (850 to 950 deg. C) though its efficiency (32%) was lower than urea, while 50-50% solution of urea and ammonium carbonate gave higher efficiency than ammonium carbonate but slightly lesser than urea within a wide temperature range (875 to 1125 deg. C). It was also observed that the NOx removal efficiency was increased with increasing the molar ratio. (author)

  11. Collagen proteins exchange O with demineralisation and gelatinisation reagents and also with atmospheric moisture.

    Science.gov (United States)

    von Holstein, Isabella; von Tersch, Matthew; Coutu, Ashley N; Penkman, Kirsty E H; Makarewicz, Cheryl A; Collins, Matthew J

    2018-01-23

    The oxygen isotope composition of collagen proteins is a potential indicator of adult residential location, useful for provenancing in ecology, archaeology and forensics. In acidic solution, proteins can exchange O from carboxylic acid moieties with reagent O. This study investigated whether this exchange occurs during demineralisation and gelatinisation preparation of bone/ivory collagen. EDTA and HCl demineralisation or gelatinisation reagents were made up in waters with different δ 18 O values, and were used to extract collagen from four skeletal tissue samples. Aliquots of extracted collagen were exposed to two different atmospheric waters, at 120°C and ambient temperature, and subsequently dried in a vacuum oven at 40°C or by freeze drying. Sample δ 18 O values were measured by HT/EA pyrolysis-IRMS using a zero-blank autosampler. Collagen samples exchanged O with both reagent waters and atmospheric water, which altered sample δ 18 O values. Exchange with reagent waters occurred in all extraction methods, but was greater at lower pH. Damage to the collagen samples during extraction increased O exchange. The nature of exchange of O with atmospheric water depended on the temperature of exposure: kinetic fractionation of O was identified at 120°C but not at ambient temperature. Exchange was difficult to quantify due to high variability of δ 18 O value between experimental replicates. Studies of δ 18 O values in collagen proteins should avoid extraction methods using acid solutions. This article is protected by copyright. All rights reserved.

  12. 9 CFR 130.18 - User fees for veterinary diagnostic reagents produced at NVSL or other authorized site (excluding...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for veterinary diagnostic reagents produced at NVSL or other authorized site (excluding FADDL). 130.18 Section 130.18 Animals and... § 130.18 User fees for veterinary diagnostic reagents produced at NVSL or other authorized site...

  13. Rapid diagnosis of avian influenza virus in wild birds: Use of a portable rRT-PCR and freeze-dried reagents in the field

    Science.gov (United States)

    Takekawa, John Y.; Hill, N.J.; Schultz, A.K.; Iverson, S.A.; Cardona, C.J.; Boyce, W.M.; Dudley, J.P.

    2011-01-01

    Wild birds have been implicated in the spread of highly pathogenic avian influenza (HPAI) of the H5N1 subtype, prompting surveillance along migratory flyways. Sampling of wild birds for avian influenza virus (AIV) is often conducted in remote regions, but results are often delayed because of the need to transport samples to a laboratory equipped for molecular testing. Real-time reverse transcriptase polymerase chain reaction (rRT-PCR) is a molecular technique that offers one of the most accurate and sensitive methods for diagnosis of AIV. The previously strict lab protocols needed for rRT-PCR are now being adapted for the field. Development of freeze-dried (lyophilized) reagents that do not require cold chain, with sensitivity at the level of wet reagents has brought on-site remote testing to a practical goal. Here we present a method for the rapid diagnosis of AIV in wild birds using an rRT-PCR unit (Ruggedized Advanced Pathogen Identification Device or RAPID, Idaho Technologies, Salt Lake City, UT) that employs lyophilized reagents (Influenza A Target 1 Taqman; ASAY-ASY-0109, Idaho Technologies). The reagents contain all of the necessary components for testing at appropriate concentrations in a single tube: primers, probes, enzymes, buffers and internal positive controls, eliminating errors associated with improper storage or handling of wet reagents. The portable unit performs a screen for Influenza A by targeting the matrix gene and yields results in 2-3 hours. Genetic subtyping is also possible with H5 and H7 primer sets that target the hemagglutinin gene. The system is suitable for use on cloacal and oropharyngeal samples collected from wild birds, as demonstrated here on the migratory shorebird species, the western sandpiper (Calidrus mauri) captured in Northern California. Animal handling followed protocols approved by the Animal Care and Use Committee of the U.S. Geological Survey Western Ecological Research Center and permits of the U.S. Geological Survey

  14. Determination of the water content in tetra-ammonium uranyl tricarbonate by the Karl Fischer reagent method

    International Nuclear Information System (INIS)

    Sisti, C.; Grigoletto, T.

    1990-08-01

    Two methods are compared for the determination of water content in tetra-ammonium uranyl tricarbonate by the Karl Fischer reagent method. In the first method it is Known that the carbonate reacts stoichiometrically with the iodine content of the Karl Fischer reagent in the same way it reacts with the water (mole of apparent H 2 O per mole of carbonate is produced). In this case, the carbonate content in the sample is determined and a suitable correction is applied to take into account the apparent water results. In the second method it is performed an extraction of the moisture by adding methanol to the sample in an independent flask. After the decantation, an aliquot of the clear supernatant methanol is taken for the determination of water content by the Karl Fischer reagent method. (author) [pt

  15. Remediation of polluted soils contaminated with Linear Alkyl Benzenes using Fenton's reagent

    Directory of Open Access Journals (Sweden)

    Douglas do Nascimento Silva

    2005-06-01

    Full Text Available Linear Alkyl Benzenes (LABs are used as insulating oil for electric cables. When it happens a spill, LABs they are basically sorbed in the soil, because, these compounds have high hidrophobicity and low vapor pressure. The conventional methods of treatment of soils are not efficient. The Fenton's reaction (reaction between a solution of iron II and hydrogen peroxide it generates hydroxyl radicals, not selective, and capable of oxidize a great variety of organic compounds. A study was conducted to evaluate the viability of use of the Fenton's reagents to promote the remediation of polluted soils with Linear Alkyl Benzenes. A column was especially projected for these experiments, packed with a sandy and other soil loamy. The pH of the soil was not altered. The obtained results demonstrated the technical viability of the process of injection of the Fenton's reagents for the treatment of polluted areas with LABs.Os Linear Alquilbenzenos (LABs são usados como fluido refrigerante de cabos elétricos. Quando ocorre um vazamento, os LABs ficam basicamente adsorvidos no solo, pois, são compostos bastante hidrofóbicos e com baixa pressão de vapor. Os métodos convencionais de tratamento de solos não são eficientes. A reação de Fenton (solução de ferro II e peróxido de hidrogênio gera radicais hidroxila, não seletivos, e capazes de oxidar uma grande variedade de compostos orgânicos, chegando a mineralização dos mesmos. Neste trabalho foi estudada a viabilidade de utilização dos reagentes de Fenton para promover a remediação de solos contaminados com LABs. Utilizou-se uma coluna especialmente projetada para estes experimentos, empacotada com um solo arenoso e outro argiloso. O pH do solo não foi alterado. Os resultados obtidos demonstram a viabilidade técnica do processo de injeção dos reagentes de Fenton para o tratamento de áreas contaminadas com LABs.

  16. Copper(I) mediated cross-coupling of amino acid derived organozinc reagents with acid chlorides

    DEFF Research Database (Denmark)

    Hjelmgaard, Thomas; Tanner, David Ackland

    2006-01-01

    This paper describes the development of a straightforward experimental protocol for copper-mediated cross-coupling of amino acid derived beta-amido-alkylzinc iodides 1 and 3 with a range of acid chlorides. The present method uses CuCN center dot 2LiCl as the copper source and for organozinc reagent...... 1 the methodology appears to be limited to reaction with more stable acid chlorides, providing the desired products in moderate yields. When applied to organozinc reagent 3, however, the protocol is more general and provides the products in good yields in all but one of the cases tested....

  17. In-line electrochemical reagent generation coupled to a flow injection biamperometric system for the determination of sulfite in beverage samples.

    Science.gov (United States)

    de Paula, Nattany T G; Barbosa, Elaine M O; da Silva, Paulo A B; de Souza, Gustavo C S; Nascimento, Valberes B; Lavorante, André F

    2016-07-15

    This work reports an in-line electrochemical reagent generation coupled to a flow injection biamperometric procedure for the determination of SO3(2-). The method was based on a redox reaction between the I3(-) and SO3(2-) ions, after the diffusion of SO2 through a gas diffusion chamber. Under optimum experimental conditions, a linear response ranging from 1.0 to 12.0 mg L(-1) (R=0.9999 and n=7), a detection and quantification limit estimated at 0.26 and 0.86 mg L(-1), respectively, a standard deviation relative of 0.4% (n=10) for a reference solution of 4.0 mg L(-1) SO3(2-) and sampling throughput for 40 determinations per hour were achieved. Addition and recovery tests with juice and wine samples were performed resulting in a range between 92% and 110%. There were no significant differences at a 95% confidence level in the analysis of eight samples when comparing the new method with a reference procedure. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. First two-reagent vitamin D assay for general clinical chemistry.

    Science.gov (United States)

    Saida, Fakhri B; Padilla-Chee, Mario; Dou, Chao; Yuan, Chong

    2018-05-01

    Vitamin D is a lipid-soluble molecule that plays key physiological roles in the metabolism of calcium, phosphate and magnesium. Recent studies show that deficiency in vitamin D is linked to cardiovascular diseases, autoimmune diseases and cancer. As a result, regular monitoring of 25-OH vitamin D (the main circulating form of vitamin D) is becoming essential. Current 25-OH vitamin D testing methodologies are cumbersome (too many reagents, long incubation times, phase separation) and are not compatible with general clinical chemistry platforms. Here, we report on a novel method to detect 25-OH vitamin D that is fast (results in 10 min or less), simple (two reagents) and compatible with virtually all general clinical chemistry analyzers. An immunoturbidimetric assay for 25-OH vitamin D (the Diazyme EZ Vitamin D Assay) has been developed using nanoparticles and vitamin D-specific antibodies. The performance of the assay kit, which consists of two reagents and five calibrators, was tested on the Beckman AU680 analyzer (AU680). The new assay was precise, sensitive (LOD = 7.2 nmol/L), linear (up to 390.1 nmol/L) and correlated strongly (R 2  > 0.95) with major commercial 25-OH vitamin D assays. Additionally, the assay was found to be the fastest to date, with the first results obtained within 10 min. Throughput on the AU680 was estimated at over 300 tests per hour. The newly developed 25-OH vitamin D assay is fast, precise and accurate. It can be run on most general chemistry analyzers. This assay aims at providing vitamin D-testing capabilities to all clinical chemistry laboratories. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Measurement of the enzymes lactate dehydrogenase and creatine kinase using reflectance spectroscopy and reagent strips.

    Science.gov (United States)

    Stevens, J F; Tsang, W; Newall, R G

    1983-01-01

    Two new methods for the assay of total activities of lactate dehydrogenase and creatine kinase are described, in which the enzyme activities are measured from a solid-state reagent strip during a kinetic reaction, the reaction being monitored in the ultra-violet region of the spectrum by reflectance spectroscopy. The performances of these methods are evaluated, and compared to conventional "wet" chemistry methods. The solid-phase reagent methods demonstrated precision and accuracy acceptable for diagnostic purposes, and were easy to use by trained operators. PMID:6655069

  20. "I Wish My People Can Be Like the Ducks": Children's References to Internal States with Siblings and Friends from Early to Middle Childhood

    Science.gov (United States)

    Leach, Jamie; Howe, Nina; DeHart, Ganie

    2017-01-01

    The present study investigated children's internal state language during play with their sibling and friend across early and middle childhood. Specifically, the category type of internal state language (e.g., cognitions and goals), referent (e.g., own and other), and associations with children's birth order were examined. A total of 65 (T1: Time…

  1. Internationalism and Globalization as Contexts for International Education

    Science.gov (United States)

    Cambridge, James; Thompson, Jeff

    2004-01-01

    A problem with the construction of an inclusive definition of international education is that the word 'international' has a variety of connotations. It is proposed that the term 'international education' is ambiguous because it appears to refer to contrasting usages in educational studies. International education is frequently discussed in the…

  2. Oxygen Activated, Palladium Nanoparticle Catalyzed, Ultrafast Cross-Coupling of Organolithium Reagents

    NARCIS (Netherlands)

    Heijnen, Dorus; Tosi, Filippo; Vila, Carlos; Stuart, Marc C. A.; Elsinga, Philip H.; Szymanski, Wiktor; Feringa, Ben L.

    2017-01-01

    The discovery of an ultrafast cross-coupling of alkyland aryllithium reagents with a range of aryl bromides is presented. The essential role of molecular oxygen to form the active palladium catalyst was established; palladium nanoparticles that are highly active in cross-coupling reactions with

  3. Validity and interobserver agreement of reagent strips for measurement of glucosuria

    NARCIS (Netherlands)

    Bekhof, Jolita; Kollen, Boudewijn J.; Groot-Jebbink, Liesbeth J. M.; Deiman, Corrie; Van de Leur, Sjef J. C. M.; Van Straaten, Henrica L. M.

    Background. Measurement of glucosuria by means of a visually readable reagent test strip is frequently used in a wide variety of clinical settings. The aim of this study was to evaluate the validity and reliability of this semi-quantitative measurement of glucosuria compared to laboratory

  4. Copper-catalyzed trifluoromethylation of arylsulfinate salts using an electrophilic trifluoromethylation reagent

    KAUST Repository

    Lin, Xiaoxi

    2013-03-01

    A copper-catalyzed method for the trifluoromethylation of arylsulfinates with Togni\\'s reagent has been developed, affording aryltrifluoromethylsulfones in moderate to good yields. A wide range of functional groups in arylsulfinates are compatible with the reaction conditions. © 2013 Elsevier Ltd. All rights reserved.

  5. Small-scale one -pot reductive alkylation of unprotected aminocyclitols with supported reagents

    Czech Academy of Sciences Publication Activity Database

    Šíša, Miroslav; Trapero, A.; Llebaria, A.; Delgado, A.

    -, č. 19 (2008), s. 3167-3170 ISSN 0039-7881 Institutional research plan: CEZ:AV0Z40550506 Keywords : alkylation s * aldehydes * supported reagents * aminocyclitols Subject RIV: CC - Organic Chemistry Impact factor: 2.470, year: 2008

  6. Complete internal audit of a mammography service in a reference institution for breast imaging.

    Science.gov (United States)

    Badan, Gustavo Machado; Roveda Júnior, Décio; Ferreira, Carlos Alberto Pecci; de Noronha Junior, Ozeas Alves

    2014-01-01

    Undertaking of a complete audit of the service of mammography, as recommended by BI-RADS(®), in a private reference institution for breast cancer diagnosis in the city of São Paulo, SP, Brazil, and comparison of results with those recommended by the literature. Retrospective, analytical and cross-sectional study including 8,000 patients submitted to mammography in the period between April 2010 and March 2011, whose results were subjected to an internal audit. The patients were followed-up until December 2012. The radiological classification of 7,249 screening mammograms, according to BI-RADS, was the following: category 0 (1.43%), 1 (7.82%), 2 (80.76%), 3 (8.35%), 4 (1.46%), 5 (0.15%) and 6 (0.03%). The breast cancer detection ratio was 4.8 cases per 1,000 mammograms. Ductal carcinoma in situ was found in 22.8% of cases. Positive predictive values for categories 3, 4 and 5 were 1.3%, 41.3% and 100%, respectively. In the present study, the sensitivity of the method was 97.1% and specificity, 97.4%. The complete internal audit of a service of mammography is essential to evaluate the quality of such service, which reflects on an early breast cancer detection and reduction of mortality rates.

  7. Determination of the isotopic ratio 234 U/238 U and 235 U/238 U in uranium commercial reagents by alpha spectroscopy

    International Nuclear Information System (INIS)

    Iturbe G, J.L.

    1990-02-01

    In this work the determination of the isotope ratio 234 U/ 238 U and 235 U/ 238 U obtained by means of the alpha spectroscopy technique in uranium reagents of commercial marks is presented. The analyzed uranium reagents were: UO 2 (*) nuclear purity, UO 3 (*) poly-science, metallic uranium, uranyl nitrate and uranyl acetate Merck, uranyl acetate and uranyl nitrate Baker, uranyl nitrate (*) of the Refinement and Conversion Department of the ININ, uranyl acetate (*) Medi-Lab Sigma of Mexico and uranyl nitrate Em Science. The obtained results show that the reagents that are suitable with asterisk (*) are in radioactive balance among the one 234 U/ 238 U, since the obtained value went near to the unit. In the case of the isotope ratio 235 U/ 238 U the near value was also obtained the one that marks the literature that is to say 0.04347, what indicates that these reagents contain the isotope of 235 U in the percentage found in the nature of 0.71%. The other reagents are in radioactive imbalance among the 234 U/ 238 U, the found values fluctuated between 0.4187 and 0.1677, and for the quotient of activities 235 U/ 238 U its were of 0.0226, and the lowest of 0.01084. Also in these reagents it was at the 236 U as impurity. The isotope of 236 U is an isotope produced artificially, for what is supposed that the reagents that are in radioactive imbalance were synthesized starting from irradiated fuel. (Author)

  8. On some investigation features of sorption of flotation reagents labelled by soft β-emitters on mineral surface

    International Nuclear Information System (INIS)

    Korobochkin, V.P.; Gladyshev, V.P.; Latypova, O.A.

    1983-01-01

    A correction for self-absorption, taking into account concrete dimensions of mineral grain during sorption of flotation reagents on mineral surface is deduced. On the basis of the regularity obtained problems of the sensitivity of the determination method of reagent activity sorbed by minerals which are labelled by radioactive isotopes are considered. Improved technique is described and statistical analysis of the experimental data obtained is carried out

  9. Performing in-situ chemical oxidation with Fenton's Reagent at a former gas work in Rotterdam

    Energy Technology Data Exchange (ETDEWEB)

    Plaisier, W.; Pancras, T. [In-situ Technieken BV, Wageningen (Netherlands); Bennen, M.; Bouwhuis, E. [Public Works Rotterdam (Netherlands)

    2003-07-01

    In-Situ Technieken BV is the first company in the Netherlands to apply full-scale in-situ chemical oxidation (ISCO) by means of Fenton's reagent or permanganates. The use of ISCO for soil remediation purposes originated in the USA. After three years of practical experience in the Netherlands it can be stated that ISCO has become a proven technology for source area treatment in the Netherlands as well. We present the results of a pilot ISCO treatment program with Fenton's reagent that was performed at the former gas works facility 'Feyenoord'. The site is one of the largest gas works facilities built in Rotterdam. The former gas production activities have lead to severe pollution of soil and groundwater over an area of approximately 3 hectares. Both laboratory and field observations showed that it would be very difficult to execute an efficient Fenton's reagent ISCO treatment program at this specific site for the following reasons. First of all, the contamination consisting of tar and tar-related compounds is found in an anthropogenic (man-made) soil of 9 meter in thickness. Secondly, high contents of carbonates and organic material were found in the soils, which act as a scavenger for the hydroxyl free radical in a Fenton's reagent ISCO system. The pilot test was performed in two phases with an intermediate period of 2 months. The injection of totally 24 tonnes hydrogen peroxide (50%) was anticipated. Reactions of the reagents in the soil were very strong. The presence of old (forgotten) boreholes and an intensive drainage system, in combination with the aggressive reaction resulted in short-circuiting of reagents to the surface. Out of the proposed 24 tonnes of hydrogen peroxide (50%) only 14.5 tonnes were injected. This would have effect on the amount of contamination oxidized. Nevertheless, the oxidation had a significant effect on the soil contamination. A reduction of approximately 90% for PAH was obtained. Reduction was also

  10. A two-reagent neutralization scheme for controlling the migration of contaminants from a uranium mill tailing disposal pond

    International Nuclear Information System (INIS)

    Dodson, M.E.; Opitz, B.E.; Sherwood, D.R.

    1985-01-01

    Techniques for reducing contaminant migration from tailings liquor impoundments and evaporation ponds are being investigated by the Pacific Northwest Laboratory as part of the Nuclear Regulatory Commission's Uranium Research and Recovery Program. Building upon previous studies investigating single-reagent neutralization, laboratory experiments were conducted to evaluate the performance of a two-reagent neutralization scheme for the treatment of acidic uranium mill tailings liquors. Acidic tailings liquor, pH 3 neutralization to pH 4.0 followed by continued neutralization with lime to pH 7.3, resulted in the highest solution quality with respect to the Environmental Protection Agency's water quality guidelines. Furthermore, the two-reagent neutralization scheme is the most cost-effective treatment procedure tested to date

  11. Copper-catalyzed asymmetric ring opening of oxabicyclic alkenes with organolithium reagents

    NARCIS (Netherlands)

    Bos, Pieter H.; Rudolph, Alena; Pérez, Manuel; Fañanás-Mastral, Martín; Harutyunyan, Syuzanna R.; Feringa, Bernard

    2012-01-01

    A highly efficient method is reported for the asymmetric ring opening of oxabicyclic alkenes with organolithium reagents. Using a copper/chiral phosphoramidite complex together with a Lewis acid (BF3·OEt2), full selectivity for the anti isomer and excellent enantioselectivities were obtained for the

  12. N-m-nitrocinnamoylphenylhydroxyl-amine as reagent for amperometric determination of yttrium

    International Nuclear Information System (INIS)

    Oliferenko, G.L.; Gallaj, Z.A.; Sheina, N.M.; Shvedene, N.V.

    1983-01-01

    Possibility of using organic reagent of unsaturated N-arylsubstituted derivatives class of hydroxamic acids N-m-nitrocinnamoyl phenylhydroxylamire (NCPHA) for amperometric titration of yttrium using indication of e.t.p. by current of reagent oxidation on graphite electrode is investigated. Metal and the NCPHA form difficultly soluble complex with ratio of yttrium to the NCPHA, which is equal to 1:3. Buffer mixtures of 0.1MNH 3 +0.1MCH 3 COOH composis tion with pH 6.3-7.5 are optimal background solutions for amperometric titration of yttrium. The proposed method permits to determine 10-600 μkg of yttrium in the volume of 10 ml. Effect of the series of strange elements on titration of yttrium with NCPHA (Ca, Mg, Mn (2), Al, CU (2), Fe (3) REE and others) is studied. The developed method is used for yttrium determination in luminophores of Casub(n)-- Ysub(m)Fsub(z)xMn(2) (1-10%) composition

  13. Body mass index in Saudi Arabian children and adolescents: A national reference and comparison with international standards

    International Nuclear Information System (INIS)

    Al Herbish, Abdullah S; ElMouzan, Mohammed I; AlSalloum, Abdullah A; AlQureshi, Mansour M; AlOmar, Ahmed A; Fster, Peter J; Kecojevic, Tatjana

    2009-01-01

    Because there are no reference standards for body mass index (BMI) in Saudi children, we established BMI reference percentiles for normal Saudi Arabian children and adolescents and compared them with international standards. Data from a stratified multistage probability sample were collected from the 13 health regions in Saudi Arabia, as part of a nationwide health profile survey of Saudi Arabian children and adolescents conducted to establish normal physical growth references. Selected households were visited by a trained team. Weight and length/height were measured and recorded following the WHO recommended procedures using the same equipment, which were subjected to both calibration and intra/interobserver variations. Survey of 11 874 eligible households yielded 35 275 full-term and healthy children and adolescents who were subjected to anthropometric measurements. Four BMI curves were produced, from birth to 36 months and 2 to 19 years for girls and boys. The 3rd, 5th, 10th ,25th , 5oth , 75th ,85th , 90th , 95th , and 97th percentiles were produced and compared with the WHO and CDC BMI charts. In the higher percentiles, the Saudi children differed from Western counterparts, indicating that Saudi children have equal or higher BMIs. The BMI curves reflect statistically representative BMI values for Saudi Arabian children and adolescents. (author)

  14. Synthesis of netlike gold nanoparticles using ampicillin as a stabilizing reagent and its application

    International Nuclear Information System (INIS)

    Song, Y.Z.; Zhou, J.F.; Song, Y.; Cheng, Z.P.; Xu, J.

    2012-01-01

    Graphical abstract: Electrochemical deposition of netlike gold nanoparticles (GNPs) on the surface of glassy carbon electrode and preparation of netlike GNPs in aqueous solution using ampicillin as a stabilizing reagent were proposed. The catalytic properties of netlike gold nanoparticles on the glassy carbon electrode for dopamine were demonstrated. The results indicate that the netlike gold nanoparticle modified electrode has an excellent repeatability and reproducibility. Display Omitted Highlights: ► Synthesis of netlike gold nanoparticles using ampicillin as a stabilizing reagent. ► Excellent repeatability and reproducibility of netlike gold nanoparticle modified glassy carbon electrode. ► The catalytic properties of netlike gold nanoparticle for dopamine. -- Abstract: Electrochemical deposition of netlike gold nanoparticles on the surface of glassy carbon electrode and preparation of netlike GNPs in aqueous solution using ampicillin as a stabilizing reagent were proposed. The netlike gold nanoparticles were characterized by scanning electron microscope, transmission electron microscope, infrared spectrometer, UV spectrophotometer, powder X-ray diffractometer and electrochemical analyzer. The catalysis of the netlike gold nanoparticles on the glassy carbon electrode for dopamine was demonstrated. The results indicate that the gold nanoparticle modified electrode has an excellent repeatability and reproducibility.

  15. Inactivation of Escherichia coli glycerol kinase by 5'-(p-(fluorosulfonyl)benzoyl))adenosine: protection by the hydrolyzed reagent

    Energy Technology Data Exchange (ETDEWEB)

    Pettigrew, D.W.

    1987-03-24

    Incubation of Escherichia coli glycerol kinase with 5'-(p-(fluorosulfonyl)benzoyl)adenosine (FSO/sub 2/BzAdo) at pH 8.0 and 25/sup 0/C results in the loss of enzyme activity, which is not restored by the addition of ..beta..-mercaptoethanol or dithiothreitol. The FSO/sub 2/BzAdo concentration dependence of the inactivation kinetics is described by a mechanism that includes the equilibrium binding of the reagent to the enzyme prior to a first-order inactivation reaction in addition to effects of reagent hydrolysis. The hydrolysis of the reagent has two effects on the observed kinetics. The first effect is deviation from pseudo-first-order kinetic behavior due to depletion of the reagent. The second effect is the novel protection of the enzyme from inactivation due to binding of the sulfonate hydrolysis product. Determinations of the reaction stoichiometry with /sup 3/H-labeled FSO/sub 2/BzAdo show that the inactivation is associated with the covalent incorporation of 1.08 mol of reagent/mol of enzyme subunit. Ligand protection experiments show that ATP, AMP, dAMP, NADH, 5'-adenylyl imidodiphosphate, and the sulfonate hydrolysis product of FSO/sub 2/BzAdo provide protection from inactivation. The protection obtained with ATMP is not dependent on Mg/sup 2 +/. The results are consistent with modification by FSO/sub 2/BzAdo of a single adenine nucleotide binding site per enzyme subunit.

  16. Paper Strip-based Fluorometric Determination of Cyanide with an Internal Reference

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong-Nam; Hong, Jong-In [Seoul National University, Seoul (Korea, Republic of); Seo, Hyejin; Shin, Ik-Soo [Soongsil University, Seoul (Korea, Republic of)

    2016-08-15

    The rapid, selective, and sensitive determination of cyanide anion (CN{sup -}) using a simple paper strip is highly attractive because cyanide is acutely lethal to living organisms via all routes of administration, including alcohol consumption and inhaling cigarette smoke. Here, a synthetic probe (1) was designed for the selective determination of cyanide. The probe displays rapid and large blue spectral change (Δλ{sub abs}=148 nm, Δλ{sub em}= 165 nm) with respect to target recognition. Probe 1 exhibits a strong push-pull electronic effect and comprises a dimethylaminoaryl group as a donor and malononitrile as an acceptor; the π-conjugation system can be destroyed by the Michael-type addition of cyanide at the electrophilic β-positions of the nitrile groups, resulting in the marked emergence of a peak at λ{sub em}= 515 nm. The developed probe was successfully applied to a paper test strip because of its noticeable optical changes upon reaction with cyanide. The fabricated dumbbell-shaped paper strip with an internal reference allowed the cyanide detection, which is indispensable for quantitative analysis in point-of-care testing. The paper strip test showed selective response to cyanide, with a linear correlation in the range of 0-25 mM in a simple and cost-effective manner.

  17. Paper Strip-based Fluorometric Determination of Cyanide with an Internal Reference

    International Nuclear Information System (INIS)

    Lee, Dong-Nam; Hong, Jong-In; Seo, Hyejin; Shin, Ik-Soo

    2016-01-01

    The rapid, selective, and sensitive determination of cyanide anion (CN"-) using a simple paper strip is highly attractive because cyanide is acutely lethal to living organisms via all routes of administration, including alcohol consumption and inhaling cigarette smoke. Here, a synthetic probe (1) was designed for the selective determination of cyanide. The probe displays rapid and large blue spectral change (Δλ_a_b_s=148 nm, Δλ_e_m= 165 nm) with respect to target recognition. Probe 1 exhibits a strong push-pull electronic effect and comprises a dimethylaminoaryl group as a donor and malononitrile as an acceptor; the π-conjugation system can be destroyed by the Michael-type addition of cyanide at the electrophilic β-positions of the nitrile groups, resulting in the marked emergence of a peak at λ_e_m= 515 nm. The developed probe was successfully applied to a paper test strip because of its noticeable optical changes upon reaction with cyanide. The fabricated dumbbell-shaped paper strip with an internal reference allowed the cyanide detection, which is indispensable for quantitative analysis in point-of-care testing. The paper strip test showed selective response to cyanide, with a linear correlation in the range of 0-25 mM in a simple and cost-effective manner.

  18. [Reference values of apolipoproteins A1 and B. Contribution of international standardization. Travail collaboratif entre la SFBC, l'Arcol et le SFRL].

    Science.gov (United States)

    Steinmetz, J; Caces, E; Couderc, R; Beucler, I; Legrand, A; Henny, J

    1997-01-01

    The utilization of two WHO reference materials, liquid and lyophilized, permitted international standardization of apolipoprotein measurements. We report here the results of a collaborative study between Arcol, SFBC and SFRL in order to establish reference ranges for apo A1 and B on nine standardized systems. A population of 1027 men and women supposed healthy, 4 to 60 year old, have been selected in two Centers for Preventive Medicine. The serum samples were aliquoted frozen at -20 degrees C the day of sampling and analysed by the manufacturers with IFCC standardized calibrants. A specific quality control was performed using a frozen pool of sera. For apo A1, the centile 2.5 of the reference population varies from 1.04 to 1.16 g/l. The range values for the centile 97.5 varies from 1.87 to 2.24 g/l. For apoB, the centile 2.5 varies from 0.43 to 0.57 g/l, and the centile 97.5 from 1.30 to 1.39 g/l. Only one system has a problem of dispersion with an upper limit equal to 1.20 g/l. These results improve that international standardization allowed actually a good comparability of the results, especially for apoB.

  19. New data on masking reagents in complexometry

    International Nuclear Information System (INIS)

    Yurist, I.M.; Talmud, M.M.; Zajtsev, P.M.

    1985-01-01

    Recent literature data on employing inorganic and organic oxygen-, nitrogen- and sulfur-containing substances as masking reagents (MR) in complexonometry of alkali earths, rare earths and transition elements are reviewed for the period of 1971-1983. Effectiveness of any type of MR is shown to be dependent on the electron configuration of a cation being masked. Sr, La, Th, V(6), Zr, Hf, V(5), Nb(5), Ta(5), Mo(6), W(6) a.o. are masked by oxygen-containing ligands. Zn, Cd, Fe(2, 3), Co(2, 3), Ni, etc. are masked by nitrogen- and sulfur-bearing ligands. Thiocompounds mask mainly In, Tl(3), Sn(2), Pb, Bi

  20. Hydrophilic interaction liquid chromatography of anthranilic acid-labelled oligosaccharides with a 4-aminobenzoic acid ethyl ester-labelled dextran hydrolysate internal standard.

    Science.gov (United States)

    Neville, David C A; Alonzi, Dominic S; Butters, Terry D

    2012-04-13

    Hydrophilic interaction liquid chromatography (HILIC) of fluorescently labelled oligosaccharides is used in many laboratories to analyse complex oligosaccharide mixtures. Separations are routinely performed using a TSK gel-Amide 80 HPLC column, and retention times of different oligosaccharide species are converted to glucose unit (GU) values that are determined with reference to an external standard. However, if retention times were to be compared with an internal standard, consistent and more accurate GU values would be obtained. We present a method to perform internal standard-calibrated HILIC of fluorescently labelled oligosaccharides. The method relies on co-injection of 4-aminobenzoic acid ethyl ester (4-ABEE)-labelled internal standard and detection by UV absorption, with 2-AA (2-aminobenzoic acid)-labelled oligosaccharides. 4-ABEE is a UV chromophore and a fluorophore, but there is no overlap of the fluorescent spectrum of 4-ABEE with the commonly used fluorescent reagents. The dual nature of 4-ABEE allows for accurate calculation of the delay between UV and fluorescent signals when determining the GU values of individual oligosaccharides. The GU values obtained are inherently more accurate as slight differences in gradients that can influence retention are negated by use of an internal standard. Therefore, this paper provides the first method for determination of HPLC-derived GU values of fluorescently labelled oligosaccharides using an internal calibrant. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Tratamento de água subterrânea contaminada com compostos organoclorados usando ferro elementar e o reagente de Fenton Treatment of groundwater contaminated with chlorinated compounds using elemental iron and Fenton's reagent

    Directory of Open Access Journals (Sweden)

    Tatiana Langbeck de Arruda

    2007-01-01

    Full Text Available The remediation of groundwater containing organochlorine compounds was evaluated using a reductive system with zero-valent iron, and the reductive process coupled with Fenton's reagent. The concentration of the individual target compounds reached up to 400 mg L-1 in the sample. Marked reductions in the chlorinated compounds were observed in the reductive process. The degradation followed pseudo-first-order kinetics in terms of the contaminant and was dependent on the sample contact time with the solid reducing agent. An oxidative test with Fenton's reagent, followed by the reductive assay, showed that tetrachloroethylene was further reduced up to three times the initial concentration. The destruction of chloroform, however, demands an additional treatment.

  2. Reference Value Advisor: a new freeware set of macroinstructions to calculate reference intervals with Microsoft Excel.

    Science.gov (United States)

    Geffré, Anne; Concordet, Didier; Braun, Jean-Pierre; Trumel, Catherine

    2011-03-01

    International recommendations for determination of reference intervals have been recently updated, especially for small reference sample groups, and use of the robust method and Box-Cox transformation is now recommended. Unfortunately, these methods are not included in most software programs used for data analysis by clinical laboratories. We have created a set of macroinstructions, named Reference Value Advisor, for use in Microsoft Excel to calculate reference limits applying different methods. For any series of data, Reference Value Advisor calculates reference limits (with 90% confidence intervals [CI]) using a nonparametric method when n≥40 and by parametric and robust methods from native and Box-Cox transformed values; tests normality of distributions using the Anderson-Darling test and outliers using Tukey and Dixon-Reed tests; displays the distribution of values in dot plots and histograms and constructs Q-Q plots for visual inspection of normality; and provides minimal guidelines in the form of comments based on international recommendations. The critical steps in determination of reference intervals are correct selection of as many reference individuals as possible and analysis of specimens in controlled preanalytical and analytical conditions. Computing tools cannot compensate for flaws in selection and size of the reference sample group and handling and analysis of samples. However, if those steps are performed properly, Reference Value Advisor, available as freeware at http://www.biostat.envt.fr/spip/spip.php?article63, permits rapid assessment and comparison of results calculated using different methods, including currently unavailable methods. This allows for selection of the most appropriate method, especially as the program provides the CI of limits. It should be useful in veterinary clinical pathology when only small reference sample groups are available. ©2011 American Society for Veterinary Clinical Pathology.

  3. Diferencias en las prevalencias de desnutrición al usarse referencias nacionales e internacionales Differences in the prevalence of malnutrition resulting from using a national growth reference or an international growth reference

    Directory of Open Access Journals (Sweden)

    Evelia Edith Oyhenart

    2005-09-01

    prevalencia de retraso del crecimiento.OBJECTIVE: To evaluate if using an international growth reference versus a national growth reference leads to differences in the prevalences of low weight-for-height (wasting and low height-for-age (stunting in a sample of children 8 to 14 years old. METHODS: A cross-sectional study was carried out with a sample of 1 470 school-children (both boys and girls in the city of La Plata, in the province of Buenos Aires, Argentina. Based on the data on weight and height, Z-scores were calculated with regard to the reference values from the United States of America's first and second National Health and Nutrition Examination Survey (NHANES I and NHANES II, and the reference values for Argentina from the Argentine Pediatric Society. The prevalences of wasting and stunting were calculated, using as the cutoff point two standard deviations below the median of the reference. The prevalences were compared using the chi-squared test with Yates' correction, and odds ratios (ORs and 95% confidence intervals (95% CIs were calculated. RESULTS: The international reference was positively associated with a higher prevalence of stunting in the entire sample (OR = 5.12; 95% CI: 3.27 to 8.05, in the boys (OR = 4.36; 95% CI: 2.43 to 7.93, and in the girls (OR = 6.32; 95% CI: 3.10 to 13.27. The prevalence of wasting was similar with both references. The distribution of height-for-age was skewed to the left with respect to the international reference and to the right with respect to the Argentine reference, while the distribution of weight-for-height overlapped both references. CONCLUSIONS: The differences in the prevalences of stunting calculated according to the two references that were used indicate a different nutritional status for the population studied. The increase in the height of the children with respect to the Argentine reference points to the presence of a positive secular trend, and the increase can explain part of the differences in the prevalence

  4. Point-of-care Devices: Non-Newtonian Whole Blood Behavior and Capillary Flow on Reagent-coated Walls

    Directory of Open Access Journals (Sweden)

    Jean BERTHIER

    2016-08-01

    Full Text Available Most point-of-care (POC and patient self-testing (PST devices are based on the analysis of whole blood taken from a finger prick. Whole blood contains a bountiful of information about the donor’s health. We analyze here two particularities of microsystems for blood analysis: the blood non-Newtonian behavior, and the capillary flow in reagent-coated channels. Capillarity is the most commonly used method to move fluids in portable systems. It is shown first that the capillary flow of blood does not follow the Lucas-Washburn-Rideal law when the capillary flow velocity is small, due to its non-Newtonian rheology and to the formation of rouleaux of RBCs. In a second step, the capillary flow of blood on reagent-coated surfaces is investigated; first experimentally by observing the spreading of a droplet of blood on different reagent-coated substrates; second theoretically and numerically using the general law for spontaneous capillary flows and the Evolver numerical program.

  5. Reagents for radioimmunological determination of carcinoembryonic antigen (CEA)

    International Nuclear Information System (INIS)

    Albert, Z.; Balbierz, H.; Breberowicz, J.

    1978-01-01

    The work was undertaken to prepare the reagents for carcinoembryonic antigen (CEA) radioimmunoassay with double antibody method. The CEA standard of high immunoreactivity was prepared and purified. The purified CEA was used for immunozation of goats. The goat anti - CEA sera were received. IgG fraction from normal goat serum was purified and used for the production of horse anti-goat IgG serum which was then used in the radioimmunoassay of CEA. The labelling of CEA with iodine-125 has been carried out be means of the enzymatic method.(Z.R.)

  6. Fluorographene Modified by Grignard Reagents: A Broad Range of Functional Nanomaterials

    Czech Academy of Sciences Publication Activity Database

    Mazánek, V.; Libánská, A.; Šturala, J.; Bouša, D.; Sedmidubský, D.; Pumera, M.; Janoušek, Zbyněk; Plutnar, Jan; Sofer, Z.

    2017-01-01

    Roč. 23, č. 8 (2017), s. 1956-1964 ISSN 0947-6539 R&D Projects: GA ČR(CZ) GA15-09001S Institutional support: RVO:61388963 Keywords : alkylation * click chemistry * fluorine * graphene * Grignard reagents Subject RIV: CC - Organic Chemistry OBOR OECD: Organic chemistry Impact factor: 5.317, year: 2016

  7. Protein assisted fluorescence enhancement of a dansyl containing fluorescent reagent: detection of Hg+ ion in aqueous medium.

    Science.gov (United States)

    Srivastava, Priyanka; Shahid, Mohammad; Misra, Arvind

    2011-07-21

    Intramolecular charge transfer (ICT) based fluorescent reagents containing a dansyl fluorophore have been synthesized and characterized. The reagent 1 and its complex, 1+Hg(2+) in sodium acetate buffer (pH 6.7) revealed considerable fluorescence enhancement (switched-on) in the presence of bovine serum albumin (BSA) with 10 ppb detection sensitivity. (1)H NMR spectral analysis suggests complexation between 1 and Hg(2+) ion involving the N,N-dimethylamino and carboxylic functions.

  8. Use of toxicity assays for evaluating the effectiveness of groundwater remediation with Fenton’s reagent

    DEFF Research Database (Denmark)

    Kusk, Kresten Ole; Bennedsen, Lars; Christophersen, Mette

    2011-01-01

    evaluates in situ chemical oxidation (ISCO) using modified Fenton’s reagent (H2O2 + chelated Fe2+) as a groundwater remedy. Three injections were performed over a period to test treatment efficacy. Performance monitoring samples were collected from two depths both prior to and during treatment, and analyzed...... treatment with Fenton’s reagent the toxicity had increased and now needed 7100 times dilution to reduce toxicity to the LC10 probably due to mobilization of metals. It is concluded that toxicity assay is a useful tool for evaluating samples from contaminated sites and that toxicity assays and chemical...

  9. Determining the normal range for IGF-I, IGFBP-3, and ALS: new reference data based on current internal standards.

    Science.gov (United States)

    Ertl, Diana-Alexandra; Gleiss, Andreas; Sagmeister, Susanne; Haeusler, Gabriele

    2014-09-01

    The measurement of insulin-like growth factors (IGF-I) and insulin-like growth factor-binding protein (IGFBP-3) often serves as first-line testing in children with growth disorders. The role of acid-labile subunit (ALS) as a screening parameter for homozygous or heterozygous mutations of the ALS gene still has to be determined. IGF-I, IGFBP-3, and ALS were measured in 252 samples from children and adolescents. Reference curves were fitted using generalized additive model for location, scale and shape (GAMLSS) models and SD-Scores were calculated. Bootstrap analysis was used to quantify the uncertainty of the estimated percentiles. Bland-Altman plots were used to investigate the discrepancy between our newly estimated standard deviation scores (SDS) and SDS calculated on the basis of previous reference data. We present reference data for enzyme-linked immunosorbent assay (ELISA) measurements based on recommended internal standard for IGF-I, IGFBP-3, and ALS suitable for calculation of SD-scores. The Bland-Altman plot shows a rough agreement between the previous SDS calculation and our new one only for SDS around 1; for SDS at -2, an average difference of 0.83 SD was noticed. Our IGF-I reference values for the interval of interest in diagnosing growth hormone deficiency (GHD) (prepubertal age) are solid as proved by bootstrap analysis. The difference in calculated SD scores by using data provided previously highlights the importance of using labor and method specific reference data.

  10. Reagent-free bacterial identification using multivariate analysis of transmission spectra

    Science.gov (United States)

    Smith, Jennifer M.; Huffman, Debra E.; Acosta, Dayanis; Serebrennikova, Yulia; García-Rubio, Luis; Leparc, German F.

    2012-10-01

    The identification of bacterial pathogens from culture is critical to the proper administration of antibiotics and patient treatment. Many of the tests currently used in the clinical microbiology laboratory for bacterial identification today can be highly sensitive and specific; however, they have the additional burdens of complexity, cost, and the need for specialized reagents. We present an innovative, reagent-free method for the identification of pathogens from culture. A clinical study has been initiated to evaluate the sensitivity and specificity of this approach. Multiwavelength transmission spectra were generated from a set of clinical isolates including Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, and Staphylococcus aureus. Spectra of an initial training set of these target organisms were used to create identification models representing the spectral variability of each species using multivariate statistical techniques. Next, the spectra of the blinded isolates of targeted species were identified using the model achieving >94% sensitivity and >98% specificity, with 100% accuracy for P. aeruginosa and S. aureus. The results from this on-going clinical study indicate this approach is a powerful and exciting technique for identification of pathogens. The menu of models is being expanded to include other bacterial genera and species of clinical significance.

  11. Alkaline phosphatase-fused repebody as a new format of immuno-reagent for an immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyo-Deok; Lee, Joong-jae [Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of); Kim, Yu Jung [Industrial Biotechnology and Bioenergy Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon (Korea, Republic of); Hantschel, Oliver [School of Life Sciences, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne (Switzerland); Lee, Seung-Goo [Industrial Biotechnology and Bioenergy Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon (Korea, Republic of); Kim, Hak-Sung, E-mail: hskim76@kaist.ac.kr [Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of)

    2017-01-15

    Enzyme-linked immunoassays based on an antibody-antigen interaction are widely used in biological and medical sciences. However, the conjugation of an enzyme to antibodies needs an additional chemical process, usually resulting in randomly cross-linked molecules and a loss of the binding affinity and enzyme activity. Herein, we present the development of an alkaline phosphatase-fused repebody as a new format of immuno-reagent for immunoassays. A repebody specifically binding to human TNF-α (hTNF-α) was selected through a phage display, and its binding affinity was increased up to 49 nM using a modular engineering approach. A monomeric alkaline phosphatase (mAP), which was previously isolated from a metagenome library, was genetically fused to the repebody as a signal generator, and the resulting repebody-mAP fusion protein was used for direct and sandwich immunoassays of hTNF-α. We demonstrate the utility and potential of the repebody-mAP fusion protein as an immuno-reagent by showing the sensitivity of 216 pg mL{sup −1} for hTNF-α in a sandwich immunoassay. Furthermore, this repebody-mAP fusion protein enabled the detection of hTNF-α spiked in a serum-supplemented medium with high accuracy and reproducibility. It is thus expected that a mAP-fused repebody can be broadly used as an immuno-reagent in immunoassays. - Highlights: • A human TNF-α (hTNF-α)-specific repebody was selected using a phage display. • A monomeric alkaline phosphatase (mAP) was genetically fused to the repebody. • mAP-fused repebody enabled detection of hTNF-α with high sensitivity and accuracy. • mAP-fused repebody can be widely used as a new immuno-reagent in immunoassays.

  12. Evaluation of Tropaeolin 000-1 as a Colorimetric Reagent for Assay ...

    African Journals Online (AJOL)

    Purpose: To explore the application of tropaeolin 000-1 reagent for the rapid, precise and accurate determination of duloxetine hydrochloride (DX) and escitalopram maleate (ECT). Methods: Determination of DX and ECT was based on the formation of complexes between the dye, DX and ECT in 0.1 M HCl. The resulting ...

  13. Miniature stick-packaging--an industrial technology for pre-storage and release of reagents in lab-on-a-chip systems.

    Science.gov (United States)

    van Oordt, Thomas; Barb, Yannick; Smetana, Jan; Zengerle, Roland; von Stetten, Felix

    2013-08-07

    Stick-packaging of goods in tubular-shaped composite-foil pouches has become a popular technology for food and drug packaging. We miniaturized stick-packaging for use in lab-on-a-chip (LOAC) systems to pre-store and on-demand release the liquid and dry reagents in a volume range of 80-500 μl. An integrated frangible seal enables the pressure-controlled release of reagents and simplifies the layout of LOAC systems, thereby making the package a functional microfluidic release unit. The frangible seal is adjusted to defined burst pressures ranging from 20 to 140 kPa. The applied ultrasonic welding process allows the packaging of temperature sensitive reagents. Stick-packs have been successfully tested applying recovery tests (where 99% (STDV = 1%) of 250 μl pre-stored liquid is released), long-term storage tests (where there is loss of only <0.5% for simulated 2 years) and air transport simulation tests. The developed technology enables the storage of a combination of liquid and dry reagents. It is a scalable technology suitable for rapid prototyping and low-cost mass production.

  14. Selection of organic acid leaching reagent for recovery of zinc and manganese from zinc-carbon and alkaline spent batteries

    Science.gov (United States)

    Yuliusman; Amiliana, R. A.; Wulandari, P. T.; Ramadhan, I. T.; Kusumadewi, F. A.

    2018-03-01

    Zinc-carbon and alkaline batteries are often used in electronic equipment that requires small quantities of power. The waste from these batteries contains valuable metals, such as zinc and manganese, that are needed in many industries and can pollute the environment if not treated properly. This paper concerns the recovery of zinc and manganese metals from zinc-carbon and alkaline spent batteries with leaching method and using organic acid as the environmental friendly leaching reagent. Three different organic acids, namely citric acid, malic acid and aspartic acid, were used as leaching reagents and compared with sulfuric acid as non-organic acid reagents that often used for leaching. The presence of hydrogen peroxide as manganese reducers was investigated for both organic and non-organic leaching reagents. The result showed that citric acid can recover 64.37% Zinc and 51.32% Manganese, while malic acid and aspartic acid could recover less than these. Hydrogen peroxide gave the significant effect for leaching manganese with non-organic acid, but not with organic acid.

  15. In situ generation of the Ohira-Bestmann reagent from stable sulfonyl azide: scalable synthesis of alkynes from aldehydes.

    Science.gov (United States)

    Jepsen, Tue Heesgaard; Kristensen, Jesper Langgaard

    2014-10-03

    We report an improved method for in situ generation of the Ohira-Bestmann reagent. Using the recently reported bench-stable imidazole-1-sulfonyl azide as diazotransfer reagent, this new method represents a scalable and convenient approach for the transformation of aldehydes into terminal alkynes. The method features an easier workup compared to the existing in situ protocol due to increased aqueous solubility of waste products.

  16. Application of Fenton's reagent as a pretreatment step in biological degradation of polyaromatic hydrocarbons

    International Nuclear Information System (INIS)

    Kelley, R.L.; Gauger, W.K.; Srivastava, V.J.

    1991-01-01

    Fenton's reagent (H 2 O 2 and Fe ++ ) has been used for chemical oxidation of numerous organic compounds in water treatment schemes. In this study, the Institute of Gas Technology (IGT) applied Fenton's treatment to polynuclear aromatic hydrocarbons (PAHs) and PAH-contaminated soils. Fenton's treatment was very reactive with PAHs, causing rapid modification of the parental compounds to oxidized products and complete degradation to CO 2 . This treatment was more effective on chemically reactive PAHs, such as benzo(a)pyrene and phenanthrene. Important parameters and conditions for Fenton's treatment of PAHs in solution and soil matrices have been identified. As much as 99% of the PAHs on soil matrices can be removed by treatment with Fenton's reagent

  17. New methods and reagents to improve the ferret model for human influenza infections

    DEFF Research Database (Denmark)

    Martel, Cyril Jean-Marie; Kirkeby, Svend; Aasted, Bent

    The ferret has been extensively used to study human influenza infections. However, its value as a model has suffered from the limited set of reagents and methods available for this animal. We have recently tested a large number of monoclonal antibodies cross-reacting with ferret CD markers (CD8, ...... improvements of the model will aim at establishing a reliable RT-PCR for ferret cytokines, as well as investigating the location of influenza receptors and viral particles in the upper and lower respiratory tract via immunohistochemistry......The ferret has been extensively used to study human influenza infections. However, its value as a model has suffered from the limited set of reagents and methods available for this animal. We have recently tested a large number of monoclonal antibodies cross-reacting with ferret CD markers (CD8, CD...

  18. Conjugate additions of a simple monosilylcopper reagent with use of the CuI.DMS complex: stereoselectivities and a dramatic impact by DMS.

    Science.gov (United States)

    Dambacher, Jesse; Bergdahl, Mikael

    2005-01-21

    Conjugate additions utilizing the simple monosilylcuprate reagent Li[PhMe2SiCuI] to alpha,beta-unsaturated carbonyl compounds are described. The presence of dimethyl sulfide (DMS), either as a component originating from the (CuI)4(DMS)3 complex or as a solvent added, has an amazing influence on both chemical yield and the level of diastereomeric ratio (dr) of the products. Gilman-type silylcyanocuprates {Li(Ph2MeSi)2Cu/LiCN} have previously been used to guarantee good results in conjugate addition reactions. External additives such as HMPA, tributylphosphine, or dialkylzinc are not necessary in conjunction with the simple Li[PhMe2SiCuI] reagent. It is demonstrated that the monosilylcuprate reagent with DMS as the solvent is very useful with sterically hindered (beta,beta-disubstituted) enones, and provides very high yields of the beta-silylated 1,4-addition products. Since there is no oligomerization problem associated with the simple monosilylcuprate reagent, this reagent should be considered as a very useful 1,4-silyl donor to enals, enones, and enoates in conjugate addition reactions.

  19. Uptake of DNA by cancer cells without a transfection reagent

    Directory of Open Access Journals (Sweden)

    Yanping Kong

    Full Text Available Abstract Background Cancer cells exhibit elevated levels of glucose uptake and may obtain pre-formed, diet-derived fatty acids from the bloodstream to boost their rapid growth; they may also use nucleic acid from their microenvironment. The study of processing nucleic acid by cancer cells will help improve the understanding of the metabolism of cancer. DNA is commonly packaged into a viral or lipid particle to be transferred into cells; this process is called transfection in laboratory. Cancer cells are known for having gene mutations and the evolving ability of endocytosis. Their uptake of DNAs might be different from normal cells; they may take in DNAs directly from the environment. In this report, we studied the uptake of DNAs in cancer cells without a transfection reagent. Methods A group of DNA fragments were prepared with PCR and labeled with isotope phosphorous-32 to test their uptake by Huh 7 (liver cancer and THLE3 (normal liver cells after incubation overnight by counting radioactivity of the cells’ genomic DNA. Multiple cell lines including breast cancer and lung cancer were tested with the same method. DNA molecules were also labeled with fluorescence to test the location in the cells using a kit of “label it fluorescence in situ hybridization (FISH” from Mirus (USA. Results The data demonstrated that hepatocellular carcinoma cells possess the ability to take in large DNA fragments directly without a transfection reagent whereas normal liver cells cannot. Huh7 and MDA-MB231 cells displayed a significantly higher Rhodamine density in the cytoplasmic phagosomes and this suggests that the mechanism of uptake of large DNA by cancer cells is likely endocytosis. The efficacy of uptake is related to the DNA’s size. Some cell lines of lung cancer and breast cancer also showed similar uptake of DNA. Conclusions In the present study, we have revealed the evidence that some cancer cells, but not nontumorigenic cells, can take DNA

  20. Employing natural reagents from turmeric and lime for acetic acid determination in vinegar sample

    Directory of Open Access Journals (Sweden)

    Sam-ang Supharoek

    2018-04-01

    Full Text Available A simple, rapid and environmentally friendly sequential injection analysis system employing natural extract reagents was developed for the determination of acetic acid following an acid–base reaction in the presence of an indicator. Powdered lime and turmeric were utilized as the natural base and indicator, respectively. Mixing lime and turmeric produced an orange to reddish-brown color solution which absorbed the maximum wavelength at 455 nm, with absorbance decreasing with increasing acetic acid concentration. Influential parameters including lime and turmeric concentrations, reagent and sample aspirated volumes, mixing coil length and dispensing flow rate were investigated and optimized. A standard calibration graph was plotted for 0–5.0 mmol/L acetic acid with r2 = 0.9925. Relative standard deviations (RSD at 2.0 and 4.0 mmol/L acetic acid were less than 3% (n = 7, with limit of detection (LOD and limit of quantification (LOQ at 0.12 and 0.24 mmol/L, respectively. The method was successfully applied to assay acetic acid concentration in cooking vinegar samples. Results achieved were not significantly different from those obtained following a batchwise standard AOAC titration method. Keywords: Acetic acid assay, Natural reagent, Turmeric, Lime, Sequential injection analysis

  1. Candidate reagents and procedures for the dissolution of Hanford Site single-shell tank sludges

    International Nuclear Information System (INIS)

    Schulz, W.W.; Kupfer, M.J.

    1991-10-01

    At least some of the waste in the 149 single-shell tanks (SST) at the US Department of Energy (DOE) Hanford Site will be retrieved, treated, and disposed of. Although the importance of devising efficient and cost-effective sludge dissolution procedures has long been recognized, a concerted bench-scale effort to devise and test such procedures with actual solids representative of those in Hanford Site SSTs has not been performed. Reagents that might be used, either individually or serially, to dissolve sludges include HNO 3 , HNO 3 -oxalic acid, and HNO 3 -HF. This report consolidates and updates perspectives and recommendations concerning reagents and procedures for dissolving Hanford Site SST and selected double-shell tank (DST) sludges. The principal objectives of this report are as follows: (1) Compile and review existing experimental data on dissolution of actual Hanford Site SST and DST sludges. (2) Further inform Hanford Site engineers and scientists concerning the utility of combinations of thermally unstable complexants (TUCS) reagents and various reducing agents for dissolving SST and DST sludges. (This latter technology has recently been explored at the Argonne National Laboratory.) (3) Provide guidance in laying out a comprehensive experimental program to develop technology for dissolving all types of Hanford Site SST and DST sludges. 6 refs., 1 fig., 4 tabs

  2. TAPIR: a device for automatic titration with incremental weighing of the titration reagent

    International Nuclear Information System (INIS)

    Ganivet, Michel

    TAPIR is a titration device enabling automatic analyses with weighting of the titration reagent. The titration method used can be based on potentiometry, amperometry, color indicator change... The reproducibility is about 3.10 -4 [fr

  3. Development of internal dosimetry protocols using the code MCNPx and voxelized phantoms of Reference of ICRP 110; Desenvolvimento de protocolos de dosimetria interna empregando o codigo MCNPx e fantomas voxelizados de referencia da ICRP 110

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, B.M.; Fonseca, T.C.F., E-mail: bmm@cdtn.br [Centro de esenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Trindade, B.M.; Campos, T.P.R. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-04-01

    The objective of this work was to perform internal dosimetry calculations for {sup 18}F-FDG employing the MCNPx code and ICRP 110 voxelized reference phantoms (RCP{sub A}F and RCP{sub A}M). The methodologies developed and validated here represent protocols of internal dosimetry holding a better anthropomorphic and anthropometric representation of the human model in which heterogeneous distributions of the emissions can be adopted, useful in the study of new radiopharmaceuticals and internal contamination cases. The reference phantoms were implemented to run on MCNPx. Biodistribution data of {sup 18}F-FDG radiopharmaceutical provided in ICRP 128 were used in the simulations. The organs average absorbed doses and the effective doses were calculated for each model. The values obtained were compared with two reference works available in the literature for validation purposes. The means of the difference of our values and Zankl et al., 2012 reference values were -0.3% for RCP{sub A}M and -0.4% for RCP{sub A}F. Considering Hadid et al., 2013 reference values, the means of the deviation were -2.9% and -2.2% for RCP{sub A}M and RCP{sub A}F respectively. No statistically significant differences were observed (p <0.01) between the reference values and the values calculated by the internal dosimetry protocols developed by our group. Considering the {sup 18}F-FDG validation study performed in this work, the internal dosimetry protocols developed by our group have produced suitable dosimetry data. (author)

  4. A Perspective on Reagent Diversity and Non-covalent Binding of Reactive Carbonyl Species (RCS and Effector Reagents in Non-enzymatic Glycation (NEG: Mechanistic Considerations and Implications for Future Research

    Directory of Open Access Journals (Sweden)

    Kenneth J. Rodnick

    2017-06-01

    Full Text Available This perspective focuses on illustrating the underappreciated connections between reactive carbonyl species (RCS, initial binding in the nonenzymatic glycation (NEG process, and nonenzymatic covalent protein modification (here termed NECPM. While glucose is the central species involved in NEG, recent studies indicate that the initially-bound glucose species in the NEG of human hemoglobin (HbA and human serum albumin (HSA are non-RCS ring-closed isomers. The ring-opened glucose, an RCS structure that reacts in the NEG process, is most likely generated from previously-bound ring-closed isomers undergoing concerted acid/base reactions while bound to protein. The generation of the glucose RCS can involve concomitantly-bound physiological species (e.g., inorganic phosphate, water, etc.; here termed effector reagents. Extant NEG schemes do not account for these recent findings. In addition, effector reagent reactions with glucose in the serum and erythrocyte cytosol can generate RCS (e.g., glyoxal, glyceraldehyde, etc.. Recent research has shown that these RCS covalently modify proteins in vivo via NECPM mechanisms. A general scheme that reflects both the reagent and mechanistic diversity that can lead to NEG and NECPM is presented here. A perspective that accounts for the relationships between RCS, NEG, and NECPM can facilitate the understanding of site selectivity, may help explain overall glycation rates, and may have implications for the clinical assessment/control of diabetes mellitus. In view of this perspective, concentrations of ribose, fructose, Pi, bicarbonate, counter ions, and the resulting RCS generated within intracellular and extracellular compartments may be of importance and of clinical relevance. Future research is also proposed.

  5. Analogs of N-cynnamoylphenylhydroxylamine as reagents for amperometric determination of scandium

    International Nuclear Information System (INIS)

    Shvedene, N.V.; Gallaj, Z.A.; Sheina, N.M.; Zujkova, N.V.

    1978-01-01

    To decrease the detection limit of scandium and increase selectivity of amperometric determination, oxidation of 2-furylacryloyl-N-p-chlorophenylhydroxylamine (FACPhHA) and 3-styrylacryloyl-N-phenylhydroxylamine (SAPhHA) on a graphite electrode has been studied by volt-amperometry. The possibility has been established of using the oxidation current of the reagent for plotting the titration curves. The solubility of scandium complexes with FACPhHA and SAPhHA under conditions of titration against the background with pH 6.0 has been determined and equals (2.1+-0.3)x10 -6 and (5.3+-0.3)x10 -7 , respectively. The methods have been developed of amperometric determination of scandium with the use of the considered reagents against backgrounds with pH 5.5-6.5. The use of SAPhHA has decreased the limit of scandium detection down to 0.1 mgk/ml. Besides, the amperometric method makes it possible to titrate in turbid and coloured media what is an advantage of this method. The developed method is used for determination of scandium in scandium silicide

  6. Programmable definition of nanogap electronic devices using self-inhibited reagent depletion.

    Science.gov (United States)

    Lam, Brian; Zhou, Wendi; Kelley, Shana O; Sargent, Edward H

    2015-04-27

    Electrodes exhibiting controlled nanoscale separations are required in devices for light detection, semiconductor electronics and medical diagnostics. Here we use low-cost lithography to define micron-separated electrodes, which we downscale to create three-dimensional electrodes separated by nanoscale gaps. Only by devising a new strategy, which we term electrochemical self-inhibited reagent depletion, were we able to produce a robust self-limiting nanogap manufacturing technology. We investigate the method using experiment and simulation and find that, when electrodeposition is carried out using micron-spaced electrodes simultaneously poised at the same potential, these exhibit self-inhibited reagent depletion, leading to defined and robust nanogaps. Particularly remarkable is the formation of fractal electrodes that exhibit interpenetrating jagged elements that consistently avoid electrical contact. We showcase the new technology by fabricating photodetectors with responsivities (A/W) that are one hundred times higher than previously reported photodetectors operating at the same low (1-3 V) voltages. The new strategy adds to the nanofabrication toolkit method that unites top-down template definition with bottom-up three-dimensional nanoscale features.

  7. Short communication: Adverse effect of surface-active reagents on the bioleaching of pyrite and chalcopyrite by Thiobacillus ferrooxidans.

    Science.gov (United States)

    Huerta, G; Escobar, B; Rubio, J; Badilla-Ohlbaum, R

    1995-09-01

    Oxidation of Fe(II) iron and bioleaching of pyrite and chalcopyrite by Thiobacillus ferrooxidans was adversely affected by isopropylxanthate, a flotation agent, and by LIX 984, a solvent-extraction agent, each at ≤ 1 g/l. The reagents/l were adsorbed on the bacterial surface, decreasing the bacteria's development and preventing biooxidation. Both reagents inhibited the bioleaching of pyrite and LIX 984 also inhibited the bioleaching of chalcopyrite.

  8. Sleep, Internalizing Problems, and Social Withdrawal: Unique Associations in Clinic-Referred Youth With Elevated Sluggish Cognitive Tempo Symptoms.

    Science.gov (United States)

    Rondon, Ana T; Hilton, Dane C; Jarrett, Matthew A; Ollendick, Thomas H

    2018-02-01

    We compared clinic-referred youth with ADHD + sluggish cognitive tempo (SCT; n = 34), ADHD Only ( n = 108), and SCT Only ( n = 22) on demographics, co-occurring symptomatology, comorbid diagnoses, and social functioning. In total, 164 youth (age = 6-17 years, M = 9.97) and their parent(s) presented to an outpatient clinic for a psychoeducational assessment. Between-group analyses and regressions were used to examine study variables. SCT groups were older and exhibited more parent-reported internalizing problems, externalizing problems, sleep problems, and social withdrawal on the Child Behavior Checklist. No significant differences emerged between groups on the Teacher Report Form. Regression analyses involving multiple covariates revealed that SCT symptoms were uniquely related to social withdrawal but not general social problems. Based on parent report, SCT symptoms have a unique relationship with internalizing problems, sleep problems, and social withdrawal. Future research should explore correlates of SCT in youth using multiple informants.

  9. IDEAS international contamination database: a compilation of published internal contamination cases. A tool for the internal dosimetry community

    International Nuclear Information System (INIS)

    Hurtgen, C.

    2007-01-01

    The aim of the IDEAS project was to develop General Guidelines for the Assessment of Internal Dose from Monitoring Data. The project was divided into 5 Work Packages for the major tasks. Work Package 1 entitled Collection of incorporation cases was devoted to the collection of data by means of bibliographic research (survey of the open literature), contacting and collecting data from specific organisations and using information from existing databases on incorporation cases. To ensure that the guidelines would be applicable to a wide range of practical situations, a database of cases of internal contamination including monitoring data suitable for dose assessment was compiled. The IDEAS Bibliography database and the IDEAS Internal Contamination database were prepared and some reference cases were selected for use in Work Package 3. The other Work packages of the IDEAS Project (WP-2 Preparation of evaluation software, WP-3 Evaluation of incorporation cases, WP-4 Development of the general guidelines and WP-5 Practical testing of general guidelines) have been described in detail elsewhere and can be found on the IDEAS website. A search for reference from the open literature, which contained information on cases of internal contamination from which intake and committed doses could be assessed, has been compiled into a database. The IDEAS Bibliography Database includes references to papers which might (but were not certain to) contain such information, or which included references to papers which contained such information. This database contains the usual bibliographical information: authors' name(s), year of publication, title of publication and the journal or report number. Up to now, a comprehensive Bibliography Database containing 563 references has been compiled. Not surprisingly more than half of the references are from Health Physics and Radiation Protection Dosimetry Journals.The next step was for the partners of the IDEAS project to obtain the references

  10. Mild copper-catalyzed trifluoromethylation of terminal alkynes using an electrophilic trifluoromethylating reagent

    KAUST Repository

    Weng, Zhiqiang

    2012-03-01

    A catalytic process for trifluoromethylation of terminal alkynes with Togni\\'s reagent has been developed, affording trifluoromethylated acetylenes in good to excellent yields. The reaction is conducted at room temperature and exhibits tolerance to a range of functional groups. © 2012 Elsevier Ltd. All rights reserved.

  11. The performance of the 'CentrifiChem' parallel fast analyser using packaged reagents.

    Science.gov (United States)

    Henry, P; Saunders, R A

    1975-05-01

    The CentrifiChem system was used with packaged reagent kits for the following determinations: albumin, alanine and aspartate aminotransferases, creatinine, glucose, and alpha-hydroxybutyrate and lactate dehydrogenases. The linearity obtainable for each assay was investigated, and particular attention was paid to finding the most suitable instrument settings.

  12. A soil sampling reference site: The challenge in defining reference material for sampling

    International Nuclear Information System (INIS)

    De Zorzi, Paolo; Barbizzi, Sabrina; Belli, Maria; Fajgelj, Ales; Jacimovic, Radojko; Jeran, Zvonka; Sansone, Umberto; Perk, Marcel van der

    2008-01-01

    In the frame of the international SOILSAMP project, funded and coordinated by the Italian Environmental Protection Agency, an agricultural area was established as a reference site suitable for performing soil sampling inter-comparison exercises. The reference site was characterized for trace element content in soil, in terms of the spatial and temporal variability of their mass fraction. Considering that the behaviour of long-lived radionuclides in soil can be expected to be similar to that of some stable trace elements and that the distribution of these trace elements in soil can simulate the distribution of radionuclides, the reference site characterised in term of trace elements, can be also used to compare the soil sampling strategies developed for radionuclide investigations

  13. A soil sampling reference site: The challenge in defining reference material for sampling

    Energy Technology Data Exchange (ETDEWEB)

    De Zorzi, Paolo [Agenzia per la Protezione dell' Ambiente e per i Servizi Tecnici (APAT), Servizio Metrologia Ambientale, Via di Castel Romano, Rome 100-00128 (Italy)], E-mail: paolo.dezorzi@apat.it; Barbizzi, Sabrina; Belli, Maria [Agenzia per la Protezione dell' Ambiente e per i Servizi Tecnici (APAT), Servizio Metrologia Ambientale, Via di Castel Romano, Rome 100-00128 (Italy); Fajgelj, Ales [International Atomic Energy Agency (IAEA), Agency' s Laboratories Seibersdorf, Vienna A-1400 (Austria); Jacimovic, Radojko; Jeran, Zvonka; Sansone, Umberto [Jozef Stefan Institute, Jamova 39, Ljubljana 1000 (Slovenia); Perk, Marcel van der [Department of Physical Geography, Utrecht University, P.O. Box 80115, TC Utrecht 3508 (Netherlands)

    2008-11-15

    In the frame of the international SOILSAMP project, funded and coordinated by the Italian Environmental Protection Agency, an agricultural area was established as a reference site suitable for performing soil sampling inter-comparison exercises. The reference site was characterized for trace element content in soil, in terms of the spatial and temporal variability of their mass fraction. Considering that the behaviour of long-lived radionuclides in soil can be expected to be similar to that of some stable trace elements and that the distribution of these trace elements in soil can simulate the distribution of radionuclides, the reference site characterised in term of trace elements, can be also used to compare the soil sampling strategies developed for radionuclide investigations.

  14. A soil sampling reference site: the challenge in defining reference material for sampling.

    Science.gov (United States)

    de Zorzi, Paolo; Barbizzi, Sabrina; Belli, Maria; Fajgelj, Ales; Jacimovic, Radojko; Jeran, Zvonka; Sansone, Umberto; van der Perk, Marcel

    2008-11-01

    In the frame of the international SOILSAMP project, funded and coordinated by the Italian Environmental Protection Agency, an agricultural area was established as a reference site suitable for performing soil sampling inter-comparison exercises. The reference site was characterized for trace element content in soil, in terms of the spatial and temporal variability of their mass fraction. Considering that the behaviour of long-lived radionuclides in soil can be expected to be similar to that of some stable trace elements and that the distribution of these trace elements in soil can simulate the distribution of radionuclides, the reference site characterised in term of trace elements, can be also used to compare the soil sampling strategies developed for radionuclide investigations.

  15. Dewaterability of five sewage sludges in Guangzhou conditioned with Fenton's reagent/lime and pilot-scale experiments using ultrahigh pressure filtration system.

    Science.gov (United States)

    Liang, Jialin; Huang, Shaosong; Dai, Yongkang; Li, Lei; Sun, Shuiyu

    2015-11-01

    Sludge conditioning with Fenton's reagent and lime is a valid method for sludge dewatering. This study investigated the influence of different organic matter content sludge on sludge dewatering and discussed the main mechanism of sludge conditioning by combined Fenton's reagent and lime. The results indicated that the specific resistance to filterability (SRF) of sludge was reduced efficiently by approximately 90%, when conditioned with Fenton's reagent and lime. Through single factor experiments, the optimal conditioning combinations were found. In addition, the relationship between VSS% and consumption of the reagents was detected. Furthermore, it was also demonstrated that the SRF and filtrate TOC values had a significant correlation with VSS% of sludge (including raw and conditioned). The main mechanism of sludge dewatering was also investigated. Firstly, it revealed that the dewaterability of sludge was closely correlated to extracellular polymeric substances (EPS) and bound water contents. Secondly, the results of scanning electron microscopy (SEM) stated that sludge particles were to be smaller and thinner after conditioning. And this structure could easily form outflow channels for releasing free water. Additionally, with the ultrahigh pressure filtration system, the water content of sludge cake conditioned with Fenton's reagent and lime could be reduced to below 50%. Moreover, the economic assessment shows that Fenton's reagent and lime combined with ultrahigh pressure filtration system can be an economical and viable technology for sewage sludge dewatering. Finally, three types of sludge were classified: (1) Fast to dewater; (2) Moderately fast to dewater; (3) Slow to dewater sludge. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Internal quality control of PCR-based genotyping methods

    DEFF Research Database (Denmark)

    Bladbjerg, Else-Marie; Gram, Jørgen; Jespersen, Jørgen

    2002-01-01

    Internal quality control programmes for genetic analyses are needed. We have focused on quality control aspects of selected polymorphism analyses used in thrombosis research. DNA was isolated from EDTA-blood (n = 500) and analysed for 18 polymorphisms by polymerase chain reaction (PCR), i...... because of positive reagent blanks (controls (Control of data handling revealed 0.1% reading mistakes and 0.5% entry mistakes. Based on our experiences, we propose an internal quality control programme......, electrophoresis (analytical factors), result reading and entry into a database (post-analytical factors). Furthermore, we evaluated a procedure for result confirmation. Isolated DNA was of good quality (42 micrograms/ml blood, A260/A280 ratio > 1.75, negative DNAsis tests). Occasionally, results were reanalysed...

  17. 22 CFR 212.13 - Incorporation by reference.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Incorporation by reference. 212.13 Section 212.13 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT PUBLIC INFORMATION Publication in the Federal Register § 212.13 Incorporation by reference. For purposes of this subpart B, USAID matters which...

  18. A new class of photoactivatable and carbene generating reagents with extremely high specific radioactivity. Synthesis, characterization and applications

    International Nuclear Information System (INIS)

    Weber, T.

    1994-01-01

    The main objective of this work was the development of new photocrosslinking and labeling reagents which show favourable photochemical properties and can be synthesized in an extremely high specific radioactivity. A key compound in the synthesis of these reagents was 2-tributyltin-4-(3-trifluormethyl-3H-diazirin-3-yl)-benzyl alcohol. Esters of this alcohol can be easily radioiodinated at a specific radioactivity of >2000 Ci/mmol under mild conditions. By experiments with a model compound it was shown that 2-iodo-4-(3-trifluormethyl-3H-diazirin-3-yl)-benzyl esters, upon photolysis, generate highly reactive (singlet) carbenes capable of inserting into CH-bonds. Equally important, there is no indication of loss of iodine under the photolysis conditions applied. Therefore two key requirements for photolabeling reagents are fulfilled. Several photoactivatable radioiodinated phospholipids have been synthesized. Their properties have been evaluated by labeling of the the membranes of intact erythrocytes and influenza viruses. Currently these lipids are used to study the interaction of various proteins (shown are experiments with MARCKS) with membranes. Furthermore a new class of actual label transfer crosslinkers (two thiol specific and one amino specific) have been developed. The range of potentialities of these reagents is currently being investigated. Finally a photoactivatable radioiodinated ceramide analogue suitable as a photoaffinity crosslinker has been developed with the goal of identifying the putative receptor of this second messenger-like lipid. Preliminary studies towards this goal are described. We are convinced that the reagents and methods presented in this work are valuable tools, and that they will find widespread use in future cell-biological and biochemical research. (author) figs., tabs., refs

  19. Eco-friendly synthesis for MCM-41 nanoporous materials using the non-reacted reagents in mother liquor.

    Science.gov (United States)

    Ng, Eng-Poh; Goh, Jia-Yi; Ling, Tau Chuan; Mukti, Rino R

    2013-03-04

    Nanoporous materials such as Mobil composite material number 41 (MCM-41) are attractive for applications such as catalysis, adsorption, supports, and carriers. Green synthesis of MCM-41 is particularly appealing because the chemical reagents are useful and valuable. We report on the eco-friendly synthesis of MCM-41 nanoporous materials via multi-cycle approach by re-using the non-reacted reagents in supernatant as mother liquor after separating the solid product. This approach was achieved via minimal requirement of chemical compensation where additional fresh reactants were added into the mother liquor followed by pH adjustment after each cycle of synthesis. The solid product of each successive batch was collected and characterized while the non-reacted reagents in supernatant can be recovered and re-used to produce subsequent cycle of MCM-41. The multi-cycle synthesis is demonstrated up to three times in this research. This approach suggests a low cost and eco-friendly synthesis of nanoporous material since less waste is discarded after the product has been collected, and in addition, product yield can be maintained at the high level.

  20. Flow injection spectrophotometry using natural reagent from Morinda citrifolia root for determination of aluminium in tea.

    Science.gov (United States)

    Tontrong, Sopa; Khonyoung, Supada; Jakmunee, Jaroon

    2012-05-01

    A flow injection (FI) spectrophotometric method with using natural reagent extracted from Morinda citrifolia root has been developed for determination of aluminium. The extract contained anthraquinone compounds which could react with Al(3+) to form reddish complexes which had maximum absorption wavelength at 499.0nm. The extract could be used as a reagent in FI system without further purification to obtain pure compound. A sensitive method for determination of aluminium in concentration range of 0.1-1.0mgL(-1), with detection limit of 0.05mgL(-1) was achieved. Relative standard deviations of 1.2% and 1.7% were obtained for the determination of 0.1 and 0.6mgL(-1) Al(3+) (n=11). Sample throughput of 35h(-1) was achieved with the consumption of 3mL each of carrier and reagent solutions per injection. The developed method was successfully applied to tea samples, validated by the FAAS standard method. The method is simple, fast, economical and could be classified as a greener analytical method. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. 2-Hydro-4-n-But oxypropiophenone Oxime as a spectrophotometric reagent for Fe (III)

    International Nuclear Information System (INIS)

    Purohit, K.; Desai, K.K.

    2006-01-01

    2-Hydro-4-n-But oxypropiophenone Oxime [Hipbone] has been synthesized and used for the spectrophotometric determination of Fe (III). The reagent gives purple coloured complex with Fe (III) in 50% alcoholic medium in pH range of 2.5-4.5. Beer's law is obeyed up to 23.1 ppm of Fe (III). Molar absorptivity and sandell's sensitivity at 500 nm of complex were found to be 7.062x 10 power2 lit.mol.cm and 0.079 ug of Fe (III)/cm respectively. Composition and stability constant have been determined. The reagent is successfully used for determination of Fe (III) in dolomite and in pharmaceutical sample. It is also used for the indirect determination of fluoride in tap water sample. (author)

  2. A convenient method to synthesize N-[3H]methyl-N-nitrosocarbamate transfer reagents

    International Nuclear Information System (INIS)

    Mehta, P.; Gold, B.; Konakahara, T.

    1992-01-01

    Activated N-alkyl-N-nitrosocarbamates are useful acyl transfer reagents that are employed in the synthesis of N-alkyl-N-nitrosoureas and related N-nitroso compounds. The nitrosourea products are of chemical and biological interest because they provide access to the in situ generation of highly reactive carbonium type intermediates, which, depending on their structure, can be powerful carcinogens or antineoplastic agents. The availability of radiolabeled nitrosoureas greatly facilitates studies on their chemical and biological activities. Generally, the synthesis of activated nitrosocarbamates requires condensation of radiolabeled alkylisocyanates with the appropriate alcohol. Because radiolabeled alkylisocyanates are not commercially available and/or troublesome to synthesize, we have developed an easy and economical method for preparing N-[ 3 H]methyl-N-nitrosocarbamates suitable for use as transfer reagents utilizing 1,2,2,2-tetrachloroethyl chloroformate and [ 3 H]methylamine hydrochloride as starting materials. (author)

  3. Treatment of landfill leachate by Fenton's reagent in a continuous stirred tank reactor

    International Nuclear Information System (INIS)

    Zhang Hui; Choi, H.J.; Huang, C.-P.

    2006-01-01

    The treatment of landfill leachate by Fenton process was carried out in a continuous stirred tank reactor (CSTR). The effect of operating conditions such as reaction time, hydraulic retention time, pH, H 2 O 2 to Fe(II) molar ratio, Fenton's reagent dosage, initial COD strength, and temperature on the efficacy of Fenton process was investigated. It is demonstrated that Fenton's reagent can effectively degrade leachate organics. Fenton process reached the steady state after three times of hydraulic retention. The oxidation of organic materials in the leachate was pH dependent and the optimal pH was 2.5. The favorable H 2 O 2 to Fe(II) molar ratio was 3, and organic removal increased as dosage increased at the favorable H 2 O 2 to Fe(II) molar ratio. Temperature gave a positive effect on organic removal

  4. WHO Expert Committee on Biological Standardization. Sixty-fifth report.

    Science.gov (United States)

    2015-01-01

    This report presents the recommendations of a WHO Expert Committee commissioned to coordinate activities leading to the adoption of international recommendations for the production and control of vaccines and other biological substances, and the establishment of international biological reference materials. Following a brief introduction, the report summarizes a number of general issues brought to the attention of the Committee. The next part of the report, of particular relevance to manufacturers and national regulatory authorities, outlines the discussions held on the development and adoption of new and revised WHO Recommendations, Guidelines and guidance documents. Following these discussions, a WHO guidance document on the Scientific principles for regulatory risk evaluation on finding an adventitious agent in a marketed vaccine was adopted along with WHO Guidelines on procedures and data requirements for changes to approved vaccines and revised WHO Recommendations to assure the quality, safety and efficacy of poliomyelitis vaccines (inactivated). Subsequent sections of the report provide information on the current status and proposed development of international reference materials in the areas of antibiotics; biotherapeutics other than blood products; blood products and related substances; in vitro diagnostic device reagents; and vaccines and related substances. A series of annexes are then presented which include an updated list of all WHO Recommendations, Guidelines and other documents on biological substances used in medicine (Annex 1) followed by the above three WHO documents adopted on the advice of the Committee (Annexes 2-4). All additions and discontinuations made during the 2014 meeting to the list of International Standards, Reference Reagents and Reference Panels for biological substances maintained by WHO are summarized in Annex 5. The updated full catalogue of WHO International Reference Preparations is available at: http://www.who.int/bloodproducts/catalogue/en/.

  5. Cu-Catalyzed Asymmetric Allylic Alkylation of Phosphonates and Phosphine Oxides with Grignard Reagents

    NARCIS (Netherlands)

    Hornillos, Valentin; Perez, Manuel; Fananas-Mastral, Martin; Feringa, Ben L.

    An efficient and highly enantioselective copper-catalyzed allylic alkylation of phosphonates and phosphine oxides with Grignard reagents and Taniaphos or phosphoramidites as chiral ligands is reported. Transformation of these products leads to a variety of new phosphorus-containing chiral

  6. The potential of curcumin reagent as a natural pH indicator for the development of an optical pH sensor

    International Nuclear Information System (INIS)

    Rosmawani Mohammad; Musa Ahmad; Jamaluddin Mohd Daud

    2007-01-01

    The potential of curcumin reagent as a natural pH indicator for the development of an optical pH sensor was discussed in this study. Curcumin has been chosen because it has never been reported before for use in the development of an optical pH sensor. Curcumin is a coloring constituent of turmeric that giving yellow pigmentation. Curcumin showed clear color changes, for example yellow in acidic and reddish-brown in basic solutions. The color change is fast for example within 5 seconds. Results from the study showed that a linear pH range for this reagent was observed at pH 8-12 (R 2 =0.9854). Curcumin has a good photo stability with RSD value of 1.42 % for a study period of 6 months. The RSD values of the reproducibility study were found to be 1.43 % and 0.37 % for pH 9 and pH 12, respectively. Characterisation of the immobilised curcumin reagent also showed promising results, hence a good potential for use as a sensing reagent for an optical pH sensor. (author)

  7. A Field-Portable Cell Analyzer without a Microscope and Reagents.

    Science.gov (United States)

    Seo, Dongmin; Oh, Sangwoo; Lee, Moonjin; Hwang, Yongha; Seo, Sungkyu

    2017-12-29

    This paper demonstrates a commercial-level field-portable lens-free cell analyzer called the NaviCell (No-stain and Automated Versatile Innovative cell analyzer) capable of automatically analyzing cell count and viability without employing an optical microscope and reagents. Based on the lens-free shadow imaging technique, the NaviCell (162 × 135 × 138 mm³ and 1.02 kg) has the advantage of providing analysis results with improved standard deviation between measurement results, owing to its large field of view. Importantly, the cell counting and viability testing can be analyzed without the use of any reagent, thereby simplifying the measurement procedure and reducing potential errors during sample preparation. In this study, the performance of the NaviCell for cell counting and viability testing was demonstrated using 13 and six cell lines, respectively. Based on the results of the hemocytometer ( de facto standard), the error rate (ER) and coefficient of variation (CV) of the NaviCell are approximately 3.27 and 2.16 times better than the commercial cell counter, respectively. The cell viability testing of the NaviCell also showed an ER and CV performance improvement of 5.09 and 1.8 times, respectively, demonstrating sufficient potential in the field of cell analysis.

  8. Catalytic enantioselective addition of organometallic reagents to N-formylimines using monodentate phosphoramidite ligands

    NARCIS (Netherlands)

    Pizzuti, Maria Gabriella; Minnaard, Adriaan J.; Feringa, Ben L.

    2008-01-01

    [GRAPHICS] The asymmetric synthesis of protected amines via the copper/phosphoramidite-catalyzed addition of organozine and organoaluminum reagents to N-acylimines, generated in situ from aromatic and aliphatic alpha-amidosulfones, is reported. High yields of optically active N-formyl-protected

  9. Catalytic Enantioselective Addition of Organometallic Reagents to N-Formylimines Using Monodentate Phosphoramidite Ligands

    NARCIS (Netherlands)

    Pizzuti, Maria Gabriella; Minnaard, Adriaan J.; Feringa, Bernard

    2008-01-01

    The asymmetric synthesis of protected amines via the copper/phosphoramidite-catalyzed addition of organozinc and organoaluminum reagents to N-acylimines, generated in situ from aromatic and aliphatic α-amidosulfones, is reported. High yields of optically active N-formyl-protected amines and

  10. Explaining Paradoxical Relations Between Academic Self-Concepts and Achievements: Cross-Cultural Generalizability of the Internal/External Frame of Reference Predictions Across 26 Countries

    Science.gov (United States)

    Marsh, Herbert W.; Hau, Kit-Tai

    2004-01-01

    The internal/external frame of reference (I/E) model explains a seemingly paradoxical pattern of relations between math and verbal self-concepts and corresponding measures of achievement, extends social comparison theory, and has important educational implications. In a cross-cultural study of nationally representative samples of 15-year-olds from…

  11. First-in-man open clinical trial of a combined rdESAT-6 and rCFP-10 tuberculosis specific skin test reagent.

    Directory of Open Access Journals (Sweden)

    Winnie Bergstedt

    2010-06-01

    Full Text Available Tuberculin is still the only available skin test reagent for the diagnosis of mycobacterial infection. The product has a remarkable sensitivity, but poor specificity. Previous studies, including two human phase I clinical trials, have indicated that rdESAT-6 has a potential as an improved skin test reagent. Animal studies have shown that the sensitivity may be increased by inclusion of the genetically related CFP-10 antigen in the preparation without loosing specificity.In this study a Lactococcus fermented, recombinant skin test reagent consisting of a 1ratio1 wt/wt of rdESAT-6 and CFP-10 was manufactured according to GMP standards and tested for the first time in 42 healthy adult volunteers. The two doses of 0.01 microg or 0.1 microg were injected intradermally by the Mantoux technique with 6 or 12 weeks interval. No serious adverse events and only mild adverse reactions were reported. The reagent elicited a positive skin test reaction after the first injection in one participant, who most likely was latently infected with M. tuberculosis as indicated by an appreciable IFN gamma response just below the Quantiferon(R cut-off level at the screening visit. None of the remaining participants in the four groups had any skin test reactions and sensitisation by the reagent could therefore be excluded.The investigational skin test reagent rdESAT-6 and CFP-10 appeared safe and non-sensitising in this first-in-man clinical trial in human volunteers and can now be tested in larger clinical trials involving individuals with latent M. tuberculosis infection or active TB disease.ClinicalTrials.gov NCT00793702.

  12. Influence of Fenton's reagent treatment on electrochemical properties of graphite felt for all vanadium redox flow battery

    International Nuclear Information System (INIS)

    Gao, Chao; Wang, NanFang; Peng, Sui; Liu, SuQin; Lei, Ying; Liang, XinXing; Zeng, ShanShan; Zi, HuiFang

    2013-01-01

    Highlights: ► Highly hydroxyl-functionalized graphite felt has been obtained through Fenton's reagent treatment. ► Fenton's reagent treatment involves only one step, works under ambient conditions and will never produce any toxic gas. ► The treated graphite felt exhibits superior electrochemical performance in comparison to the untreated one. -- Abstract: An environmental, economic and highly effective method for carbon fiber hydroxylated-functionalization based on Fenton's reagent treatment is used to improve the electrochemical activity of graphite felt (GF) as the positive electrode in all vanadium redox flow battery (VRFB). The effect of H 2 O 2 content in Fenton's reagent on the structure and electrochemical properties of GF is investigated. The scanning electron microscope (SEM) indicates that the surface of the treated GF is etched increasingly with the content of H 2 O 2 . The Fourier transformation infrared (FTIR) spectroscopy shows that the peak intensity of hydroxyl groups on the treated felt is increased with the H 2 O 2 concentration, which is further verified by X-ray photoelectron spectroscopy (XPS). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) show that the treated sample exhibits a higher electrochemical activity. A VRFB with the treated GF as electrodes exhibits higher coulombic, voltage and energy efficiency (98.8%, 75.1% and 74.2%) than that with the untreated GF (93.9%, 72.1% and 67.7%) at 60 mA cm −2 , and this method is even superior when compared with the reported methods

  13. Academic Librarians Should Be Sensitive to Language and Cultural Barriers When Providing Reference Service to International Students. A review of: Curry, Ann and Deborah Copeman. “Reference Service to International Students: A Field Stimulation Research Study.” Journal of Academic Librarianship 31.5 (Sep. 2005: 409‐20.

    Directory of Open Access Journals (Sweden)

    Lorie A. Kloda

    2006-12-01

    Full Text Available Objective – To evaluate the quality of reference service provided to non‐native, English‐speaking international students in academic libraries.Design – Field stimulation (unobtrusive testing.Setting – Eleven college and university libraries in the lower mainland of British Columbia, Canada, in the fall of 2003.Subjects – Library staff offering reference service at one of the participating libraries.Methods – The study utilized field stimulation, whereby an individual, or “proxy,” posed as a library user and initiated a reference encounter with library staff at each institution. In each case the proxy asked the same question to the library staff member. After the interaction was completed the proxy recorded all observed behaviours. Data were collected using a checklist of actions; a narrative record written by the proxy; and several evaluative questions. Each library was visited by the same proxy on two separate occasions for a total of 22 visits, of which 20 instances resulted in usable data. The narrative recordings of the reference encounters were analyzed using an open coding process.Main results – In 75% of the cases, the proxy was “‘satisfied” or “very satisfied” with help received from the library staff member and was “likely to” or “definitely would return to the staff member” in the future. The reference encounters lasted between a few minutes to half an hour in length, with most lasting between 5 and 15 minutes. Encounters that were brief (less than 5 minutes resulted in an evaluation of “dissatisfied” or “very dissatisfied” and “not likely to” or “definitely would not return.” Encounters where the library staff member extended an invitation to the proxy to return in the future were all rated with “high satisfaction” and “willingness to return.” The following reference service actions were observed in at least half of the encounters:• Asked questions for clarification (20

  14. Classical kinematic model for direct reactions of oriented reagents

    International Nuclear Information System (INIS)

    Schechter, I.; Prisant, M.G.; Levine, R.D.

    1987-01-01

    A simple kinematic model based on the concept of an orientation-dependent critical configuration for reaction is introduced and applied. The model serves two complementary purposes. In the predictive mode the model provides an easily implemented procedure for computing the reactivity of oriented reagents (including those actually amenable to measure) from a given potential energy surface. The predictions of the model are compared against classical trajectory results for the H + D 2 reaction. By use of realistic potential energy surfaces the model is applied to the Li + HF and O + HCl reactions where the HX molecules are pumped by a polarized laser. A given classical trajectory is deemed reactive or not according to whether it can surmount the barrier at that particular orientation. The essential difference with the model of Levine and Bernstein is that the averaging over initial conditions is performed by using a Monte Carlo integration. One can therefore use the correct orientation-dependent shape (and not only height) of the barrier to reaction and, furthermore, use oriented or aligned reagents. Since the only numerical step is a Monte Carlo sampling of initial conditions, very many trajectories can be run. This suffices to determine the reaction cross section for different initial conditions. To probe the products, they have employed the kinematic approach of Elsum and Gordon. The result is a model where, under varying initial conditions, examining final-state distributions or screening different potential energy surfaces can be efficiently carried out

  15. 42 CFR 493.1252 - Standard: Test systems, equipment, instruments, reagents, materials, and supplies.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Test systems, equipment, instruments... SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY... storage of reagents and specimens, accurate and reliable test system operation, and test result reporting...

  16. Palladium-Catalysed Direct Cross-Coupling of Organolithium Reagents with Aryl and Vinyl Triflates

    NARCIS (Netherlands)

    Vila, Carlos; Hornillos, Valentin; Giannerini, Massimo; Fananas-Mastral, Martin; Feringa, Bernard L.

    2014-01-01

    Carbon-Carbon Bond Formation Carbon-carbon bond formation by the cross-coupling of highly reactive organolithium reagents is a major challenge. Recently, it was demonstrated that palladium catalysts are able to couple organic halides with various organolithium species under mild conditions in a

  17. It guides for the storage of reagents and elimination of waste of the laboratories of the headquarters Rodrigo Facio of the Costa Rica University

    International Nuclear Information System (INIS)

    Mata Bonilla, E. R.

    1996-01-01

    The Project guides for the storage of chemical reagents and elimination of waste of the laboratories of the campus Rodrigo Facio of the Costa Rica University, the objective to settle down in written form a method of storage of chemical reagents, as well as the basic elements for the establishment of a system of handling of chemical residuals for the laboratories of the campus. The storage of reagents in a laboratory requires that the probability of an accident is minimized and it should include the following elements: a classification of reagents and their later segregation (in accordance with the reactivity of each group), ventilation, illumination, controls and alarms in the event of fires, control of spills and an uniform system for the identification of reagents and storage area. The elimination of residuals of chemical reagents requires a series of stages to carry out of this operation in sure form for people, the property and the environment. In the first place it is required of an outline of the whole process of elimination of the waste, later on a system of classification of the produced residuals should be included that it contemplates the final method of elimination of the residual. Other elements that should take into account are: reduction of the volume of the waste, gathering methods, labeled and transport. In this work intends the System of Classification of Substances of the United Nations as classification method, segregation, and storage of the reagents of the laboratories of the campus [es

  18. Flotation of copper-bearing shale in solutions of inorganic salts and organic reagents

    Directory of Open Access Journals (Sweden)

    Ratajczak Tomasz

    2017-01-01

    Full Text Available Flotation data on copper-bearing shale in aqueous solutions of inorganic electrolytes (NaCl, Na2SO4, KPF6, NH4Cl and organic reagents (ethylamine, propylamine as frothers were presented and discussed. The relationships between shale flotation, surface tension of aqueous solution and foam height during bubbling with air in the flotation system were presented. It has been found that flotation of shale in the presence of inorganic salts the yield was directly proportional to the surface tension of the aqueous solution of salt and inversely proportional to the height of the foam. On the other hand, for organic reagents solutions (short chain amines, a reverse effect has been observed in relation to the inorganic compounds studied, that is the yield of copper-bearing shale flotation and the foam height were inversely proportional to the surface tension of the amine solution.

  19. Functionalization of epoxy esters with alcohols as stoichiometric reagents.

    Science.gov (United States)

    Pavlović, Dona; Modec, Barbara; Dolenc, Darko

    2015-01-01

    Glycidyl esters, frequently employed as reactive groups on polymeric supports, were functionalized with alcohols as stoichiometric reagents, yielding β-alkoxyalcohols. Among the solvents studied, best results were obtained in ethers in the presence of a strong proton acid as a catalyst. Alcohols include simple alkanols, diols, protected polyols, 3-butyn-1-ol 3-hydroxypropanenitrile and cholesterol. This protocol represents a convenient way for introduction of various functionalities onto epoxy-functionalized polymers. Under the reaction conditions, some side reactions take place, mostly due to the reactive ester group and water present in the reaction mixture.

  20. Meta-Cresol Purple Reference Material® (RM) for Seawater pH Measurements

    Science.gov (United States)

    Easley, R. A.; Waters, J. F.; Place, B. J.; Pratt, K. W.

    2016-02-01

    The pH of seawater is a fundamental quantity that governs the carbon dioxide - carbonate system in the world's oceans. High quality pH measurements for long-term monitoring, shipboard studies, and shorter-term biological studies (mesocosm and field experiments) can be ensured through a reference material (RM) that is compatible with existing procedures and which is traceable to primary pH measurement metrology. High-precision spectrophotometric measurements of seawater pH using an indicator dye such as meta-cresol purple (mCP) are well established. However, traceability of these measurements to the International System of Units (SI) additionally requires characterizing the spectrophotometric pH response of the dye in multiple artificial seawater buffers that themselves are benchmarked via primary pH (Harned cell) measurements at a range of pH, salinity, and temperature. NIST is currently developing such a mCP pH RM using this approach. This material will also incorporate new procedures developed at NIST for assessing the purity and homogeneity of the mCP reagent itself. The resulting mCP will provide long-term (years) stability and ease of shipment compared to artificial seawater pH buffers. These efforts will provide the oceanographic user community with a NIST issued mCP (RM), characterized as to its molar absorptivity values and acid dissociation constants (pKa), with uncertainties that comply with the Guide to the Expression of Uncertainty in Measurement (GUM).

  1. Measurement of dabigatran: previously demonstrated Hemoclot® Thrombin Inhibitor assay reagent instability on Sysmex CS-2100i is no longer an issue

    DEFF Research Database (Denmark)

    Comuth, Willemijn; Faaborg, Louise; Henriksen, Linda Østervig

    2017-01-01

    hours. Since the reagent composition was unchanged, the increased stability could be due to changed logistics by the supplier, with stock and transfer closer by. Previously demonstrated HTI reagent instability is no longer an issue at our laboratory. The reliability of results of clinical studies...

  2. Validation of psychoanalytic theories: towards a conceptualization of references.

    Science.gov (United States)

    Zachrisson, Anders; Zachrisson, Henrik Daae

    2005-10-01

    The authors discuss criteria for the validation of psychoanalytic theories and develop a heuristic and normative model of the references needed for this. Their core question in this paper is: can psychoanalytic theories be validated exclusively from within psychoanalytic theory (internal validation), or are references to sources of knowledge other than psychoanalysis also necessary (external validation)? They discuss aspects of the classic truth criteria correspondence and coherence, both from the point of view of contemporary psychoanalysis and of contemporary philosophy of science. The authors present arguments for both external and internal validation. Internal validation has to deal with the problems of subjectivity of observations and circularity of reasoning, external validation with the problem of relevance. They recommend a critical attitude towards psychoanalytic theories, which, by carefully scrutinizing weak points and invalidating observations in the theories, reduces the risk of wishful thinking. The authors conclude by sketching a heuristic model of validation. This model combines correspondence and coherence with internal and external validation into a four-leaf model for references for the process of validating psychoanalytic theories.

  3. Improved synthesis of glycine, taurine and sulfate conjugated bile acids as reference compounds and internal standards for ESI-MS/MS urinary profiling of inborn errors of bile acid synthesis.

    Science.gov (United States)

    Donazzolo, Elena; Gucciardi, Antonina; Mazzier, Daniela; Peggion, Cristina; Pirillo, Paola; Naturale, Mauro; Moretto, Alessandro; Giordano, Giuseppe

    2017-04-01

    Bile acid synthesis defects are rare genetic disorders characterized by a failure to produce normal bile acids (BAs), and by an accumulation of unusual and intermediary cholanoids. Measurements of cholanoids in urine samples by mass spectrometry are a gold standard for the diagnosis of these diseases. In this work improved methods for the chemical synthesis of 30 BAs conjugated with glycine, taurine and sulfate were developed. Diethyl phosphorocyanidate (DEPC) and diphenyl phosphoryl azide (DPPA) were used as coupling reagents for glycine and taurine conjugation. Sulfated BAs were obtained by sulfur trioxide-triethylamine complex (SO 3 -TEA) as sulfating agent and thereafter conjugated with glycine and taurine. All products were characterized by NMR, IR spectroscopy and high resolution mass spectrometry (HRMS). The use of these compounds as internal standards allows an improved accuracy of both identification and quantification of urinary bile acids. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Kinetics of catalyzed hydrolysis of 4-methylumbelliferyl caprylate (MUCAP) salmonella reagent

    Science.gov (United States)

    Al-Kady, Ahmed S.; Ahmed, El-Sadat I.; Gaber, M.; Hussein, Mohamed M.; Ebeid, El-Zeiny M.

    2011-09-01

    The kinetics of chemical hydrolysis including neutral, acid- and base-catalyzed hydrolysis of 4-methylumbelliferyl caprylate (MUCAP) salmonella reagent were studied at different temperatures. The rate constants and activation parameters were determined by following the build-up of fluorescence peak of the hydrolysis product 4-methylumbelliferone (4-MU). The time scale of esterase enzyme hydrolysis caused by salmonella was compared with chemical hydrolysis as a background process.

  5. Reference values for electrooculography

    International Nuclear Information System (INIS)

    Barrientos Castanno, Alberto; Herrera Mora, Maritza; Garcia Baez, Obel

    2012-01-01

    Obtain electrooculographic reference values based on the patterns set by the Standardization Committee of the International Society for Clinical Electrophysiology of Vision (ISCEV). the lowest amplitude values of the potential ranged between 388 and 882 μv in the dark phase. The light peak was obtained between 9 and 10 minutes, and during this phase the potential reached an amplitude ranging between 808 and 1 963 μv. This amplitude variability may be related to the fact that the test was conducted without pupillary mydriasis. The reference value obtained for Arden index was 1,55 to 2,87

  6. Interlaboratory Reproducibility of Droplet Digital Polymerase Chain Reaction Using a New DNA Reference Material Format.

    Science.gov (United States)

    Pinheiro, Leonardo B; O'Brien, Helen; Druce, Julian; Do, Hongdo; Kay, Pippa; Daniels, Marissa; You, Jingjing; Burke, Daniel; Griffiths, Kate; Emslie, Kerry R

    2017-11-07

    Use of droplet digital PCR technology (ddPCR) is expanding rapidly in the diversity of applications and number of users around the world. Access to relatively simple and affordable commercial ddPCR technology has attracted wide interest in use of this technology as a molecular diagnostic tool. For ddPCR to effectively transition to a molecular diagnostic setting requires processes for method validation and verification and demonstration of reproducible instrument performance. In this study, we describe the development and characterization of a DNA reference material (NMI NA008 High GC reference material) comprising a challenging methylated GC-rich DNA template under a novel 96-well microplate format. A scalable process using high precision acoustic dispensing technology was validated to produce the DNA reference material with a certified reference value expressed in amount of DNA molecules per well. An interlaboratory study, conducted using blinded NA008 High GC reference material to assess reproducibility among seven independent laboratories demonstrated less than 4.5% reproducibility relative standard deviation. With the exclusion of one laboratory, laboratories had appropriate technical competency, fully functional instrumentation, and suitable reagents to perform accurate ddPCR based DNA quantification measurements at the time of the study. The study results confirmed that NA008 High GC reference material is fit for the purpose of being used for quality control of ddPCR systems, consumables, instrumentation, and workflow.

  7. Suitable reference tissues for quantitative susceptibility mapping of the brain.

    Science.gov (United States)

    Straub, Sina; Schneider, Till M; Emmerich, Julian; Freitag, Martin T; Ziener, Christian H; Schlemmer, Heinz-Peter; Ladd, Mark E; Laun, Frederik B

    2017-07-01

    Since quantitative susceptibility mapping (QSM) quantifies magnetic susceptibility relative to a reference value, a suitable reference tissue has to be available to compare different subjects and stages of disease. To find such a suitable reference tissue for QSM of the brain, melanoma patients with and without brain metastases were measured. Twelve reference regions were chosen and assessed for stability of susceptibility values with respect to multiple intra-individual and inter-individual measurements, age, and stage of disease. Cerebrospinal fluid (CSF), the internal capsule and one region in the splenium of the corpus callosum are the regions with the smallest standard deviations of the mean susceptibility value. The mean susceptibility is 0.010 ± 0.014 ppm for CSF in the atrium of the lateral ventricles (csf post ), -0.060 ± 0.019 ppm for the posterior limb of the internal capsule (ci2), and -0.008 ± 0.019 ppm for the splenium of the corpus callosum. csf post and ci2 show nearly no dependence on age or stage of disease, whereas some other regions, e.g., the red nucleus, show moderate dependence on age or disease. The internal capsule and CSF appear to be the most suitable reference regions for QSM of the brain in the melanoma patients studied. Both showed virtually no dependence on age or disease and small variations among patients. Magn Reson Med 78:204-214, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Multielement analysis of reagents used in chemical identification of transuranic elements

    International Nuclear Information System (INIS)

    Montalvan Estrada, A.; Brigido Flores, O.; Maslov, O.D.; Dmitriev, S.N.

    2006-01-01

    For more than 40 years, chemical identification of transuranic elements has been used at the Laboratory of Nuclear Reactions of the Join Institute for Nuclear Research, Dubna, Russia, as a secondary method of identification. Chlorination of transuranic elements obtained by nuclear reactions is an important step of the procedure in order to obtain volatile compounds able to pass through a thermo chromatographic process. To access the quality of the reagents TiCl 4 and SOCl 2 multielement analysis was carried out using both X-rays fluorescence and gamma activation. It was followed the simplest procedure for reagents samples pretreatment, so further interferences from other chemical products were avoided. X-rays fluorescence analysis was performed in a spectrometer with Si(Li) detector with a resolution for Fe (K?) of 190 eV. Both Cd-109 and Am-241 were used as isotopic sources of excitation. Gamma activation analysis was carried out using the compact electron accelerator MT-25, where gamma rays are produced in a stopping target. Among the parameters of the MT-25 are the following: energy range-10-25 MeV, gamma-ray flux-10 14 photon/s, power consumption-20 kw. Measurements of the induced activity were performed with the help of a HPGe detector, thin and coaxial Ge(Li) detectors. There were identified two elements in SOCl 2 -Nickel (3*10 -6 g/g) and Antimony (2*10 -7 g/g), while there were identified three elements in TiCl 4 - Zirconium (8*10 -7 g/g), Arsenic (9*10 -7 g/g) and Antimony (5*10 -7 g/g). Only five elements were detected in trace concentrations in the two analyzed reagents, that is for more than 57 elements capable of being detected using gamma activation analysis with the MT-25 only 5 had concentrations above the detection limits of the method. Not being chemical analogs of the synthesized transuranic elements (Z-104 and 106) and not being able to alpha or fission disintegrations there is not expected any interference from them in the chemical

  9. Volumetric Titrations Using Electrolytically Generated Reagents for the Determination of Ascorbic Acid and Iron in Dietary Supplement Tablets: An Undergraduate Laboratory Experiment

    Science.gov (United States)

    Scanlon, Christopher; Gebeyehu, Zewdu; Griffin, Kameron; Dabke, Rajeev B.

    2014-01-01

    An undergraduate laboratory experiment for the volumetric quantitative analysis of ascorbic acid and iron in dietary supplement tablets is presented. Powdered samples of the dietary supplement tablets were volumetrically titrated against electrolytically generated reagents, and the mass of dietary reagent in the tablet was determined from the…

  10. Azidoimidazolinium Salts: Safe and Efficient Diazo-transfer Reagents and Unique Azido-donors.

    Science.gov (United States)

    Kitamura, Mitsuru

    2017-07-01

    2-Azido-1,3-dimethylimidazolinium chloride (ADMC) and its corresponding hexafluorophosphate (ADMP) were found to be efficient diazo-transfer reagents to various organic compounds. ADMC was prepared by the reaction of 2-chloro-1,3-dimethylimidazolinium chloride (DMC) and sodium azide. ADMP was isolated as a crystal having good thermal stability and low explosibility. ADMC and ADMP reacted with 1,3-dicarbonyl compounds under mild basic conditions to give 2-diazo-1,3-dicarbonyl compounds in high yields, which were easily isolated in virtue of the high water solubility of the by-products. ADMP showed high diazo-transfer ability to primary amines even in the absence of metal salt such as Cu(II). Using this diazotization approach, various alkyl/aryl azides were directly obtained from their corresponding primary amines in high yields. Furthermore, naphthols reacted with ADMC to give the corresponding diazonaphthoquinones in good to high yields. In addition, 2-azido-1,3-dimethylimidazolinium salts were employed as azide-transfer and migratory amidation reagents. © 2017 The Chemical Society of Japan & Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Towars a chemical reagents and residues management at the teaching laboratories of the Chemistry School of the Universidad Nacional

    OpenAIRE

    Ana Cristina Benavides Benavides; Xinia Vargas González; Gustavo Chaves Barboza; José Ángel Rodríguez Corrales

    2016-01-01

    The academic activities carried out at the School of Chemistry make indispensable to develop actions oriented toward the consolidation of a reagent and residue management system, especially in the teaching laboratories. The project “Management of reagents and residues in the teaching laboratories of the School of Chemistry” works under the Green Chemistry values which designs products and chemical processes that reduce or eliminate the use and production of dangerous substances, to benefit th...

  12. Validation of Modifications to the ANSR for Listeria Method for Improved Internal Positive Control Performance.

    Science.gov (United States)

    Alles, Susan; Meister, Evan; Hosking, Edan; Tovar, Eric; Shaulis, Rebecca; Schonfeld, Mark; Zhang, Lei; Li, Lin; Biswas, Preetha; Mozola, Mark; Donofrio, Robert; Chen, Yi

    2018-03-01

    A study was conducted to validate a minor reagent formulation change to the ANSR for Listeria method, Performance Tested MethodSM 101202. This change involves increasing the master mix volume prelyophilization by 40% and addition of salmon sperm DNA (nontarget DNA) to the master mix. These changes improve the robustness of the internal positive control response and reduce the possibility of obtaining invalid results due to weak-positive control curves. When three foods (hot dogs, Mexican-style cheese, and cantaloupe) and sponge samples taken from a stainless steel surface were tested, no significant differences in performance between the ANSR and U.S. Food and Drug Administration Bacteriological Analytical Manual or U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference culture procedures were observed for any of the matrixes as determined by probability of detection analysis. Inclusivity and exclusivity testing yielded 100% expected results for target and nontarget bacteria. Accelerated stability testing was carried out over a 7 week period and showed no decrease in assay performance over time.

  13. International energy outlook 1996

    International Nuclear Information System (INIS)

    1996-05-01

    This International Energy Outlook presents historical data from 1970 to 1993 and EIA's projections of energy consumption and carbon emissions through 2015 for 6 country groups. Prospects for individual fuels are discussed. Summary tables of the IEO96 world energy consumption, oil production, and carbon emissions projections are provided in Appendix A. The reference case projections of total foreign energy consumption and of natural gas, coal, and renewable energy were prepared using EIA's World Energy Projection System (WEPS) model. Reference case projections of foreign oil production and consumption were prepared using the International Energy Module of the National Energy Modeling System (NEMS). Nuclear consumption projections were derived from the International Nuclear Model, PC Version (PC-INM). Alternatively, nuclear capacity projections were developed using two methods: the lower reference case projections were based on analysts' knowledge of the nuclear programs in different countries; the upper reference case was generated by the World Integrated Nuclear Evaluation System (WINES)--a demand-driven model. In addition, the NEMS Coal Export Submodule (CES) was used to derive flows in international coal trade. As noted above, foreign projections of electricity demand are now projected as part of the WEPS. 64 figs., 62 tabs

  14. International energy outlook 1996

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-01

    This International Energy Outlook presents historical data from 1970 to 1993 and EIA`s projections of energy consumption and carbon emissions through 2015 for 6 country groups. Prospects for individual fuels are discussed. Summary tables of the IEO96 world energy consumption, oil production, and carbon emissions projections are provided in Appendix A. The reference case projections of total foreign energy consumption and of natural gas, coal, and renewable energy were prepared using EIA`s World Energy Projection System (WEPS) model. Reference case projections of foreign oil production and consumption were prepared using the International Energy Module of the National Energy Modeling System (NEMS). Nuclear consumption projections were derived from the International Nuclear Model, PC Version (PC-INM). Alternatively, nuclear capacity projections were developed using two methods: the lower reference case projections were based on analysts` knowledge of the nuclear programs in different countries; the upper reference case was generated by the World Integrated Nuclear Evaluation System (WINES)--a demand-driven model. In addition, the NEMS Coal Export Submodule (CES) was used to derive flows in international coal trade. As noted above, foreign projections of electricity demand are now projected as part of the WEPS. 64 figs., 62 tabs.

  15. INFLUENCE OF REAGENT PURITY ON THE ION CHROMATOGRAPHIC DETERMINATION OF BROMATE IN WATER USING 3,3'-DIMETHOXYBENZIDINE AS A PROCHROMOPHORE FOR PHOTOMETRIC DETECTION

    Science.gov (United States)

    Variable availability of the purified dihydrochloride salt of 3,3'-dimethoxybenzidine (DMB, ortho-dianisidine) led us to investigate the effects of reagent purity on the analytical results obtinaed when this reagent is used in the photometric determination of the disinfection byp...

  16. CSNI Project for Fracture Analyses of Large-Scale International Reference Experiments (Project FALSIRE)

    International Nuclear Information System (INIS)

    Bass, B.R.; Pugh, C.E.; Keeney-Walker, J.; Schulz, H.; Sievers, J.

    1993-06-01

    This report summarizes the recently completed Phase I of the Project for Fracture Analysis of Large-Scale International Reference Experiments (Project FALSIRE). Project FALSIRE was created by the Fracture Assessment Group (FAG) of Principal Working Group No. 3 (PWG/3) of the Organization for Economic Cooperation and Development (OECD)/Nuclear Energy Agency's (NEA's) Committee on the Safety of Nuclear Installations (CSNI). Motivation for the project was derived from recognition by the CSNI-PWG/3 that inconsistencies were being revealed in predictive capabilities of a variety of fracture assessment methods, especially in ductile fracture applications. As a consequence, the CSNI/FAG was formed to evaluate fracture prediction capabilities currently used in safety assessments of nuclear components. Members are from laboratories and research organizations in Western Europe, Japan, and the United States of America (USA). On behalf of the CSNI/FAG, the US Nuclear Regulatory Commission's (NRC's) Heavy-Section Steel Technology (HSST) Program at the Oak Ridge National Laboratory (ORNL) and the Gesellschaft fuer Anlagen--und Reaktorsicherheit (GRS), Koeln, Federal Republic of Germany (FRG) had responsibility for organization arrangements related to Project FALSIRE. The group is chaired by H. Schulz from GRS, Koeln, FRG

  17. CSNI Project for Fracture Analyses of Large-Scale International Reference Experiments (Project FALSIRE)

    Energy Technology Data Exchange (ETDEWEB)

    Bass, B.R.; Pugh, C.E.; Keeney-Walker, J. [Oak Ridge National Lab., TN (United States); Schulz, H.; Sievers, J. [Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) mbH, Koeln (Gemany)

    1993-06-01

    This report summarizes the recently completed Phase I of the Project for Fracture Analysis of Large-Scale International Reference Experiments (Project FALSIRE). Project FALSIRE was created by the Fracture Assessment Group (FAG) of Principal Working Group No. 3 (PWG/3) of the Organization for Economic Cooperation and Development (OECD)/Nuclear Energy Agency`s (NEA`s) Committee on the Safety of Nuclear Installations (CSNI). Motivation for the project was derived from recognition by the CSNI-PWG/3 that inconsistencies were being revealed in predictive capabilities of a variety of fracture assessment methods, especially in ductile fracture applications. As a consequence, the CSNI/FAG was formed to evaluate fracture prediction capabilities currently used in safety assessments of nuclear components. Members are from laboratories and research organizations in Western Europe, Japan, and the United States of America (USA). On behalf of the CSNI/FAG, the US Nuclear Regulatory Commission`s (NRC`s) Heavy-Section Steel Technology (HSST) Program at the Oak Ridge National Laboratory (ORNL) and the Gesellschaft fuer Anlagen--und Reaktorsicherheit (GRS), Koeln, Federal Republic of Germany (FRG) had responsibility for organization arrangements related to Project FALSIRE. The group is chaired by H. Schulz from GRS, Koeln, FRG.

  18. References from Brazilian medical journals in national publications.

    Science.gov (United States)

    Teixeira, Renan Kleber Costa; Botelho, Nara Macedo; Petroianu, Andy

    2013-01-01

    To assess whether there is a preference for international journal citation to the detriment of national ones in ten Brazilian medical journals, in two different periods. All references in the articles published in Arquivos Brasileiros de Oftalmologia, Revista Brasileira de Cirurgia Cardiovascular, Revista da Associação Médica Brasileira, São Paulo Medical Journal, Arquivos Brasileiros de Endocrinologia e Metabologia, Clinics, Jornal Brasileiro de Pneumologia, Revista da Sociedade Brasileira de Medicina Tropical, Revista Brasileira de Psiquiatria e Acta Ortopédica Brasileira in the years 2011 and 2007 were analyzed, assessing the number of articles published in national and international journals. A total of 36,125 references from 1,462 articles published in the 10 aforementioned journals were analyzed. Of the total number, 4.242 (11.74%) were from Brazilian journals. There was no significant difference between the two analyzed periods. A total of 453 (30,98%) of the articles studied non-cited brazilian papers,and 81 (5.54%) articles had more Brazilian than international references. Of total references analyzed, 11.74% were related to articles published in Brazilian journals. This number, when compared to the percentage of Brazilian articles published in the medical area, demonstrates a good number of citations of national articles. Copyright © 2012 Elsevier Editora Ltda. All rights reserved.

  19. An approach to local diagnostic reference levels (DRL's) in the context of national and international DRL's

    International Nuclear Information System (INIS)

    Rogers, A.T.

    2001-01-01

    In recent years there has been a greater focus on the management of patient doses. This effort has been driven by the realisation of both the increasing magnitude of patient doses and their variation both intra- and inter-nationally. Legislators and guidance-issuing bodies have developed the idea of 'Diagnostic Reference Levels' (DRL's). In particular, the European Union, in their Council Directive 97/43/Euratom, required Member States to develop DRL's. The UK Government, when consolidating this EU Directive into UK legislation, extended the concept of DRL's from a national to an employer level. However, the methodologies used for development of national and international DRL's do not translate to a local level and hence a new approach is required. This paper describes one particular approach made by a UK hospital to introduce 'Local DRL's' in such a manner as to aid the optimisation process. This approach utilises a dose index, based on the local patient population, which is monitored for trends. Any trend in patient dose triggers an investigation linked to the clinical audit system within the Clinical Radiology Department. It is the audit cycle that ensures a continuing move towards an optimised situation. Additional triggers may be employed such as large patient dose variations. (author)

  20. A Comparison Between the OSI Reference Model and the B-ISDN Protocol Reference Model

    DEFF Research Database (Denmark)

    Staalhagen, Lars

    1996-01-01

    This article aims at comparing the Open Systems Interconnection (OSI) Reference Model (RM) and the broadband integrated services digital network (B-ISDN) Protocol Reference Model (PRM). According to the International Telecommunications Union - Telecommunications Sector (ITU-T), the exact...... relationship between the lower layers of the OSI RM and the B-ISDN PRM is for further study. It is therefore the intention of this article to present some views on these relationships which hopefully could facilitate an interconnection between B-ISDN and data networks conforming to the OSI standards....

  1. Optically transparent, superhydrophobic methyltrimethoxysilane based silica coatings without silylating reagent

    International Nuclear Information System (INIS)

    Kavale, Mahendra S.; Mahadik, D.B.; Parale, V.G.; Wagh, P.B.; Gupta, Satish C.; Rao, A.Venkateswara; Barshilia, Harish C.

    2011-01-01

    The superhydrophobic surfaces have drawn lot of interest, in both academic and industries because of optically transparent, adherent and self-cleaning behavior. Surface chemical composition and morphology plays an important role in determining the superhydrophobic nature of coating surface. Such concert of non-wettability can be achieved, using surface modifying reagents or co-precursor method in sol-gel process. Attempts have been made to increase the hydrophobicity and optical transparency of methyltrimethoxysilane (MTMS) based silica coatings using polymethylmethacrylate (PMMA) instead of formal routes like surface modification using silylating reagents. The optically transparent, superhydrophobic uniform coatings were obtained by simple dip coating method. The molar ratio of MTMS:MeOH:H 2 O was kept constant at 1:5.63:1.58, respectively with 0.5 M NH 4 F as a catalyst and the weight percent of PMMA varied from 1 to 8. The hydrophobicity of silica coatings was analyzed by FTIR and contact angle measurements. These substrates exhibited 91% optical transmittance as compared to glass and water drop contact angle as high as 171 ± 1 deg. The effect of humidity on hydrophobic nature of coating has been studied by exposing these films at relative humidity of 90% at constant temperature of 30 deg. C for a period of 45 days. The micro-structural studies carried out by transmission electron microscopy (TEM).

  2. Photo oxidative degradation of azure-B by sono-photo-Fenton and photo-Fenton reagents

    Directory of Open Access Journals (Sweden)

    Prahlad Vaishnave

    2014-12-01

    Full Text Available A model for the decomposition of azure-B by photo-Fenton reagent in the presence of ultrasound in homogeneous aqueous solution has been described. The photochemical decomposition rate of azure-B is markedly increased in the presence of ultrasound. It is a rather inexpensive reagent for wastewater treatment. The effect of different variables like the concentration of ferric ion, concentration of dye, hydrogen peroxide, pH, light intensity etc. on the reaction rate has been observed. The progress of the sono-photochemical degradation was monitored spectrophotometrically. The optimum sono-photochemical degradation conditions were experimentally determined. The results showed that the dye was completely oxidized and degraded into CO2 and H2O. A suitable tentative mechanism for sono-photochemical bleaching of azure-B by sono-photo-Fenton’s reaction has been proposed.

  3. A convenient method to synthesize N-[[sup 3]H]methyl-N-nitrosocarbamate transfer reagents

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, P.; Gold, B. (Nebraska Univ., Omaha, NE (United States). Eppley Inst. for Research in Cancer); Konakahara, T. (Science Univiversity of Tokyo, Noda, Chiba (Japan). Faculty of Science and Technology)

    1992-11-01

    Activated N-alkyl-N-nitrosocarbamates are useful acyl transfer reagents that are employed in the synthesis of N-alkyl-N-nitrosoureas and related N-nitroso compounds. The nitrosourea products are of chemical and biological interest because they provide access to the in situ generation of highly reactive carbonium type intermediates, which, depending on their structure, can be powerful carcinogens or antineoplastic agents. The availability of radiolabeled nitrosoureas greatly facilitates studies on their chemical and biological activities. Generally, the synthesis of activated nitrosocarbamates requires condensation of radiolabeled alkylisocyanates with the appropriate alcohol. Because radiolabeled alkylisocyanates are not commercially available and/or troublesome to synthesize, we have developed an easy and economical method for preparing N-[[sup 3]H]methyl-N-nitrosocarbamates suitable for use as transfer reagents utilizing 1,2,2,2-tetrachloroethyl chloroformate and [[sup 3]H]methylamine hydrochloride as starting materials. (author).

  4. Studies on synthesis of a kind of new colour reagents bromophosphonobisazo derivatives of chromotropic acid and the effect of their constitution on colour behaviours with rare earth elements

    International Nuclear Information System (INIS)

    Bincai, W.; Yuxin, Q.; Hengchuan, L.

    1985-01-01

    Based on the previous systematic studies, this paper reports to the original constitution of chlorophosphonazo type of colour reagents, has been reformed, and a kind of 14 new asymmetrical bromophosphonobisazo colour reagents of chromotropic acid have been designed and synthesized. In the meanwhile, the relationship between constitution of colour reagents and its behaviour in colour reaction with rare earth elements has been investigated. In addition, the general colour behaviours of these reagents and the influence of organic solvents and surfactants have been preliminarily studied

  5. International cooperation

    International Nuclear Information System (INIS)

    Prieto, F.E.

    1984-01-01

    It looks doubtless that the need for an international cooperation to solve the worldwide energy problems is already a concern of individuals, institutions, and governments. This is an improvement. But there is something lacking. The author refers to the Atoms for Peace speech, the origin of the IAEA and of the subsequent spreading of the nuclear option. He also refers back to the call made by the Mexican government for a worldwide energy cooperation. He stresses the need for governments to cooperate, so that this international cooperation on energy can be put into operation for the benefit of mankind

  6. Experimental research of the impact of the dosing of chemical reagents on the dynamic behavior of regulation system of cycle chemistry

    Science.gov (United States)

    Yegoshina, O. V.; Bolshakova, N. A.

    2017-11-01

    Organization of reliable chemical control for maintaining cycle chemistry is one of the most important problems to be solved at the present time the design and operation of thermal power plants. To maintain optimal parameters of cycle chemistry are used automated chemical control system and regulation system of dosing chemical reagents. Reliability and stability analyzer readings largely determine the reliability of the water cycle chemistry. Now the most common reagents are ammonia, alkali and film-forming amines. In this paper are presented the results of studies of the impact of concentration and composition of chemical reagents for readings stability of automatic analyzers and transients time of control systems for cycles chemistry. Research of the impact of chemical reagents on the dynamic behavior of regulation system for cycle chemistry was conducted at the experimental facility of the Department of thermal power stations of the Moscow Engineering Institute. This experimental facility is model of the work of regulation system for cycle chemistry close to the actual conditions on the energy facilities CHP. Analysis of results of the impact of chemical reagent on the dynamic behavior of ammonia and film forming amines dosing systems showed that the film-forming amines dosing system is more inertia. This emphasizes the transition process of the system, in which a half times longer dosing of ammonia. Results of the study can be used to improve the monitoring systems of water chemical treatment.

  7. Conversion of coal mine drainage ochre to water treatment reagent: Production, characterisation and application for P and Zn removal.

    Science.gov (United States)

    Sapsford, Devin; Santonastaso, Marco; Thorn, Peter; Kershaw, Steven

    2015-09-01

    Coal mine drainage ochre is a ferruginous precipitate that forms from mine water in impacted watercourses and during treatment. With thousands of tonnes per annum of such ochre arising from mine water treatment in the UK alone, management of these wastes is a substantive issue. This paper demonstrates that the ochre from both active and passive treatment of coal mine drainage can be transformed into an effective water treatment reagent by simple acid dissolution and that the reagent can be used for the removal of dissolved phosphorous from municipal wastewater and zinc from non-coal mine waters. Ochre is readily soluble in H2SO4 and HCl. Ochre is more soluble in HCl with solubilities of up to 100 g/L in 20% (w/w) HCl and 68 g/L in 10% (w/w) H2SO4. For four of the eight tested ochres solubility decreased in higher concentrations of H2SO4. Ochre compositional data demonstrate that the coal mine ochres tested are relatively free from problematic levels of elements seen by other authors from acid mine drainage-derived ochre. Comparison to British Standards for use of iron-based coagulants in drinking water treatment was used as an indicator of the acceptability of use of the ochre-derived reagents in terms of potentially problematic elements. The ochre-derived reagents were found to meet the 'Grade 3' specification, except for arsenic. Thus, for application in municipal wastewater and mine water treatment additional processing may not be required. There was little observed compositional difference between solutions prepared using H2SO4 or HCl. Ochre-derived reagents showed applicability for the removal of P and Zn with removals of up to 99% and 97% respectively measured for final pH 7-8, likely due to sorption/coprecipitation. Furthermore, the results demonstrate that applying a Fe dose in the form of liquid reagent leads to a better Fe:P and Fe:Zn removal ratio compared to ochre-based sorption media tested in the literature. Copyright © 2015 The Authors. Published by

  8. The application of a monolithic triphenylphosphine reagent for conducting Appel reactions in flow microreactors.

    Science.gov (United States)

    Roper, Kimberley A; Lange, Heiko; Polyzos, Anastasios; Berry, Malcolm B; Baxendale, Ian R; Ley, Steven V

    2011-01-01

    Herein we describe the application of a monolithic triphenylphosphine reagent to the Appel reaction in flow-chemistry processing, to generate various brominated products with high purity and in excellent yields, and with no requirement for further off-line purification.

  9. Field method for estimation of fluoride in drinking groundwater by photometric measurement of spot on aluminium quinalizarin reagent paper

    OpenAIRE

    Zaher Barghouthi; Sameer Amereih

    2017-01-01

    A simple field method for determination of fluoride in drinking water using handmade fluoride reagent paper impregnated by aluminium quinalizarin complex was developed. Fluoride reacts with the impregnated reagent paper to release the free ligand with new colour, orange different from that of the complex. The change in the colour, which is proportional to the amount of fluoride, was measured by the Arsenator. The functionality of the Arsenator which is based on a photometric measurement of sp...

  10. A Stopped-Flow Kinetics Experiment for the Physical Chemistry Laboratory Using Noncorrosive Reagents

    Science.gov (United States)

    Prigodich, Richard V.

    2014-01-01

    Stopped-flow kinetics techniques are important to the study of rapid chemical and biochemical reactions. Incorporation of a stopped-flow kinetics experiment into the physical chemistry laboratory curriculum would therefore be an instructive addition. However, the usual reactions studied in such exercises employ a corrosive reagent that can over…

  11. Development and evaluation of weight and height reference ...

    African Journals Online (AJOL)

    While international reference standard exists, it has been suggested that locally generated norms would be more realistic and appropriate, especially in adults where great variations in stature among nations exist. This study was undertaken to develop a table of reference standard for weight and height for young adults in

  12. Reference Japanese man

    International Nuclear Information System (INIS)

    Tanaka, Giichiro

    1985-01-01

    To make real and accurate dose assessment method so far, it is necessitated to provide ''Reference Japanese Man'' based on anotomical, physiological and biochemical data of Japanese people instead of the Reference Man presented in ICRP Publications 23 and 30. This review describes present status of researched for the purpose of establishing of Reference Japanese Man. The Reference Japanese Man is defined as a male or female adult who lives in Japan with a Japanese life-style and food custom. His stature and body weight, and the other data was decided as mean values of male or female people of Japan. As for food custom, Japanese people take significantly smaller amount of meat and milk products than Western people, while larger intake amount of cereals and marine products such as fish or seaweeds. Weight of organs is a principal factor for internal dose assessment and mean values for living Japanese adult has been investigated and the value employable for dose assessment for organs and tissues are shown. To employ these values of Reference Japanese Man, it should be taken into account of age. Metabolic parameters should also be considered. Iodine metabolism in Japanese is quite different from that of Western people. The above-mentioned data are now tentatively employing in modification of table of MIRD method and others. (Takagi, S.)

  13. Chiral reagents in glycosylation and modification of carbohydrates.

    Science.gov (United States)

    Wang, Hao-Yuan; Blaszczyk, Stephanie A; Xiao, Guozhi; Tang, Weiping

    2018-02-05

    Carbohydrates play a significant role in numerous biological events, and the chemical synthesis of carbohydrates is vital for further studies to understand their various biological functions. Due to the structural complexity of carbohydrates, the stereoselective formation of glycosidic linkages and the site-selective modification of hydroxyl groups are very challenging and at the same time extremely important. In recent years, the rapid development of chiral reagents including both chiral auxiliaries and chiral catalysts has significantly improved the stereoselectivity for glycosylation reactions and the site-selectivity for the modification of carbohydrates. These new tools will greatly facilitate the efficient synthesis of oligosaccharides, polysaccharides, and glycoconjugates. In this tutorial review, we will summarize these advances and highlight the most recent examples.

  14. Comparison of US Birth Weight References and the International Fetal and Newborn Growth Consortium for the 21st Century Standard

    DEFF Research Database (Denmark)

    Kozuki, Naoko; Katz, Joanne; Christian, Parul

    2015-01-01

    ) status. OBJECTIVES: To compare the birth weight distributions of the INTERGROWTH-21st international standard to commonly used US references and examine the differences in the prevalence and neonatal mortality risk of SGA status (below the 10th percentile of a population reference). DESIGN, SETTING...... variance. MAIN OUTCOMES AND MEASURES: We examine neonatal mortality (death within the first 28 days after birth) as the main outcome measure. RESULTS: The pooled SGA prevalence was 23.7% (95% CI, 16.5%-31.0%) using the INTERGROWTH-21st standard compared with 36.0% (95% CI, 27.0%-45.0%) with the US 2000...... and no significant change in the associated neonatal mortality risk, resulting in a decrease in the percentage of neonatal death attributable to SGA. Our study sheds light on how previously published studies on SGA status may be reinterpreted with the introduction of this new birth weight standard....

  15. An experimental design approach for optimization of spectrophotometric method for estimation of cefixime trihydrate using ninhydrin as derivatizing reagent in bulk and pharmaceutical formulation

    Directory of Open Access Journals (Sweden)

    Yogita B. Wani

    2017-01-01

    Full Text Available The aim of the present work is to use experimental design to screen and optimize experimental variables for developing a spectrophotometric method for determining cefixime trihydrate content using ninhydrin as a derivatizing reagent. The method is based on the reaction of the amino group of cefixime with ninhydrin in an alkaline medium to form a yellow-colored derivative (λmax 436 nm. A two-level full factorial design was utilized to screen the effect of ninhydrin reagent concentration (X1, volume of ninhydrin reagent (X2, heating temperature (X3 and heating time (X4 on the formation of the cefixime–ninhydrin complex Y (absorbance. One way ANOVA and Pareto ranking analyses have shown that the ninhydrin reagent concentration (X1, volume of ninhydrin reagent (X2 and heating temperature (X3 were statistically significant factors (P < 0.05 affecting the formation of the cefixime–ninhydrin complex Y (absorbance. A Box-Behnken experimental design with response surface methodology was then utilized to evaluate the main, interaction and quadratic effects of these three factors on the selected response. With the help of a response surface plot and contour plot the optimum values of the selected factors were determined and used for further experiments. These values were a ninhydrin reagent concentration (X1 of 0.2% w/v, volume of ninhydrin reagent (X2 of 1 mL and heating temperature (X3 of 80 °C. The proposed method was validated according to the ICH Q2 (R1 method validation guidelines. The results of the present study have clearly shown that an experimental design concept may be effectively applied to the optimization of a spectrophotometric method for estimating the cefixime trihydrate content in bulk and pharmaceutical formulation with the least number of experimental runs possible.

  16. Moderate reagent mixing on an orbital shaker reduces the incubation time of enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Kumar, Saroj; Ahirwar, Rajesh; Rehman, Ishita; Nahar, Pradip

    2017-07-01

    Rapid diagnostic tests can be developed using ELISA for detection of diseases in emergency conditions. Conventional ELISA takes 1-2 days, making it unsuitable for rapid diagnostics. Here, we report the effect of reagents mixing via shaking or vortexing on the assay timing of ELISA. A 48-min protocol of ELISA involving 12-min incubations with reagent mixing at 750 rpm for every step was optimized. Contrary to this, time-optimized control ELISA performed without mixing produced similar results in 8 h, leaving a time gain of 7 h using the developed protocol. Collectively, the findings suggest the development of ELISA-based rapid diagnostics. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Nuclear Structure References (NSR) file

    International Nuclear Information System (INIS)

    Ewbank, W.B.

    1978-08-01

    The use of the Nuclear Structure References file by the Nuclear Data Project at ORNL is described. Much of the report concerns format information of interest only to those preparing input to the system or otherwise needing detailed knowledge of its internal structure. 17 figures

  18. [Substantiation of maximum permissible water level of the flotation reagent EFK-1].

    Science.gov (United States)

    Turbinskiĭ, V V

    1991-12-01

    Threshold concentrations of the flotation reagent EFK-1 in the water of reservoirs at 0.8 mg/l and 10.0 mg/l for organoleptic and total sanitary indices, respectively, were reported. Dl50 was 7469 mg/kg. The MAC of 0.8 mg/l for EFK-1 in the water of reservoirs (the limiting sign is organoleptic) was proposed.

  19. The application of a monolithic triphenylphosphine reagent for conducting Appel reactions in flow microreactors

    Directory of Open Access Journals (Sweden)

    Kimberley A. Roper

    2011-12-01

    Full Text Available Herein we describe the application of a monolithic triphenylphosphine reagent to the Appel reaction in flow-chemistry processing, to generate various brominated products with high purity and in excellent yields, and with no requirement for further off-line purification.

  20. Simple questionnaire and urine reagent strips compared to microscopy for the diagnosis of Schistosoma haematobium in a community in northern Ghana.

    Science.gov (United States)

    Bogoch, Isaac I; Andrews, Jason R; Dadzie Ephraim, Richard K; Utzinger, Jürg

    2012-10-01

    To evaluate the utility of a simple questionnaire and urine reagent strip testing for the rapid diagnosis of Schistosoma haematobium in rural northern Ghana. Cross-sectional parasitological and questionnaire survey in a community in northern Ghana. Participants provided two urine specimens that were examined under a microscope using a centrifugation method. The first urine sample was additionally subjected to reagent strip testing. A short questionnaire was administered to all participants. Microscopy of urine samples obtained from 208 individuals aged 1-77 years revealed an S. haematobium prevalence of 6.8%. The presence of any blood or protein on a urine reagent strip was 100% and 42% sensitive, and 93% and 80% specific for S. haematobium diagnosis. Questionnaires were completed by 198 individuals. Self-reported haematuria showed a sensitivity of 53% and a specificity of 85%. A dichotomous two-question panel was helpful in S. haematobium diagnosis, with working and playing near the river significantly associated with S. haematobium infection (P < 0.001). The use of urine reagent strips, coupled with questions pertaining to water contact patterns, might be considered for point-of-contact diagnosis of S. haematobium where microscopy is unavailable. © 2012 Blackwell Publishing Ltd.

  1. Glutarimidedioxime. A complexing and reducing reagent for plutonium recovery from spent nuclear fuel reprocessing

    Energy Technology Data Exchange (ETDEWEB)

    Xian, Liang [China Institute of Atomic Energy, Beijing (China). Radiochemistry Dept.; Tian, Guoxin [China Institute of Atomic Energy, Beijing (China). Radiochemistry Dept.; Lawrence Berkeley National Laboratory, Berkeley, CA (United States). Chemical Sciences Div.; Beavers, Christine M.; Teat, Simon J. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States). Advanced Light Source; Shuh, David K. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States). Chemical Sciences Div.

    2016-04-04

    Efficient separation processes for recovering uranium and plutonium from spent nuclear fuel are essential to the development of advanced nuclear fuel cycles. The performance characteristics of a new salt-free complexing and reducing reagent, glutarimidedioxime (H{sub 2}A), are reported for recovering plutonium in a PUREX process. With a phase ratio of organic to aqueous of up to 10:1, plutonium can be effectively stripped from 30 % tributyl phosphate (TBP) in kerosene into 1M HNO{sub 3} with H{sub 2}A. The complexation-reduction mechanism is illustrated with the combination of UV/Vis absorption spectra and the crystal structure of a Pu{sup IV} complex with the reagent. The fast stripping rate and the high efficiency for stripping Pu{sup IV}, through the complexation-reduction mechanism, is suitable for use in centrifugal contactors with very short contact/resident times, thereby offering significant advantages over conventional processes.

  2. Winery wastewater treatment by a combined process: long term aerated storage and Fenton's reagent.

    Science.gov (United States)

    Lucas, Marco S; Mouta, Maria; Pirra, António; Peres, José A

    2009-01-01

    The degradation of the organic pollutants present in winery wastewater was carried out by the combination of two successive steps: an aerobic biological process followed by a chemical oxidation process using Fenton's reagent. The main goal of this study was to evaluate the temporal characteristics of solids and chemical oxygen demand (COD) present in winery wastewater in a long term aerated storage bioreactor. The performance of different air dosage daily supplied to the biologic reactor, in laboratory and pilot scale, were examined. The long term hydraulic retention time, 11 weeks, contributed remarkably to the reduction of COD (about 90%) and the combination with the Fenton's reagent led to a high overall COD reduction that reached 99.5% when the mass ratio (R = H(2)O(2)/COD) used was equal to 2.5, maintaining constant the molar ratio H(2)O(2)/Fe(2+)=15.

  3. E- or Z-Selective synthesis of 4-fluorovinyl-1,2,3-triazoles with fluorinated second-generation Julia-Kocienski reagents.

    Science.gov (United States)

    Kumar, Rakesh; Singh, Govindra; Todaro, Louis J; Yang, Lijia; Zajc, Barbara

    2015-02-07

    A highly modular approach to N-substituted 4-(1-fluorovinyl)triazoles is described. In situ desilylation and Cu-catalyzed ligation reaction of TMS-protected α-fluoropropargyl benzothiazole sulfone with aryl, alkyl, and metallocenyl azides furnished second-generation Julia-Kocienski reagents in good to excellent yields. Condensation reactions of these reagents with aldehydes can be tuned to yield E or Z-alkenes selectively. Under mild conditions with DBU as the base, reactions of aldehydes furnished E-alkenes as the major isomer. On the other hand, in condensation reactions with LHMDS as the base and in appropriate solvents, both aldehydes and ketones reacted to yield fluoroalkenes with Z-selectivity. Stereochemical assignment of E/Z olefins obtained in the reaction of a ketone with two Julia reagents was performed via X-ray crystallographic analysis and comparisons of NMR data. The method allows efficient and ready diversification of the N1-substituent and substituents at the double bond.

  4. Uso do violeta de alizarina N (AVN como reagente espectrofotométrico na determinação de alumínio Use of the alizarine violet N (AVN as a spectrophotometric reagent for aluminium determination

    Directory of Open Access Journals (Sweden)

    Alailson Falcão Dantas

    2000-04-01

    Full Text Available The present work proposes the application of the 4-Hidroxy-3-(2-hydroxynaphtylazo-benzenesulphonic acid (C.I. 15670, Alizarine Violet N (AVN, as a reagent for direct aluminium determination using molecular absorption spectrophotometry in the presence of tensoatives. Al(III cation reacts with AVN in pH 9.4, forming a red complex, stable for at least 24 hours, with absorption minimum at 607nm and, against a reagent blank, (epsiloncomplex - epsilonreagent = -2.71x10(4 L.mol-1.cm-1. The reaction occurs in the presence of a Triton-X100 and CTAB tensoatives mixture, in the presence of EDTA. Al(III determination is possible in the linear range of 50 up to 400ng.mL-1, with a detection limit of 41 ng.mL-1.

  5. Effects of coal composition and flotation reagents on the water resistance of binderless briquettes

    Energy Technology Data Exchange (ETDEWEB)

    Motaung, S.R.; Mangena, S.J.; de Korte, G.J. [Syngas & Coal Technology, Sasolburg (South Africa)

    2007-10-15

    The difference in the physical properties, particularly the water resistance or wet strength, of the binderless coal briquettes produced from flotation feed and concentrate was investigated using six bituminous coals from two collieries in the Witbank Coalfield. The coal samples were analyzed for their proximate, petrographic, and mineralogical properties. The presence, in the flotation concentrates, of the reagents used during the froth flotation process was also investigated using gas chromatography. Pillow-shaped binderless briquettes were produced from coal samples at various moisture contents and a pressure of approximately 17 MPA using a Komarek B-100A double-roll press. The briquettes were tested for some physical properties (i.e., dry- and wet-compressive strengths), which were thereafter compared with the properties determined for the coal samples. The binderless briquettes produced from the flotation concentrates were more water-resistant than those produced from the flotation feed. The flotation feed and concentrates of the coals tested were found to have similar petrographic properties. As expected, the ash and kaolinite contents were found to be lower in the flotation concentrates than in the flotation feed. Flotation reagents were detected in the flotation concentrates from both collieries. From the results obtained it is concluded that the increased water resistance of the binderless briquettes produced from flotation concentrates of the coals tested is due to a combination of the fineness of the coal particles, assisted by the amount of reactive macerals (most particularly vitrinite) with the lower ash and kaolinite contents, together with the presence of the flotation reagents, particularly the collector, in the flotation concentrate.

  6. 41 CFR 101-42.1102-5 - Drugs, biologicals, and reagents other than controlled substances.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Drugs, biologicals, and reagents other than controlled substances. 101-42.1102-5 Section 101-42.1102-5 Public Contracts and Property Management Federal Property Management Regulations System FEDERAL PROPERTY MANAGEMENT REGULATIONS...

  7. NOVEL ECONOMICAL HG(0) OXIDATION REAGENT FOR MERCURY EMISSIONS CONTROL FROM COAL-FIRED BOILERS

    Science.gov (United States)

    The authors have developed a novel economical additive for elemental mercury (Hg0) removal from coal-fired boilers. The oxidation reagent was rigorously tested in a lab-scale fixed-bed column with the Norit America's FGD activated carbon (DOE's benchmark sorbent) in a typical PRB...

  8. Peptide Dendrimer/Lipid Hybrid Systems Are Efficient DNA Transfection Reagents: Structure–Activity Relationships Highlight the Role of Charge Distribution Across Dendrimer Generations

    Science.gov (United States)

    2013-01-01

    Efficient DNA delivery into cells is the prerequisite of the genetic manipulation of organisms in molecular and cellular biology as well as, ultimately, in nonviral gene therapy. Current reagents, however, are relatively inefficient, and structure–activity relationships to guide their improvement are hard to come by. We now explore peptide dendrimers as a new type of transfection reagent and provide a quantitative framework for their evaluation. A collection of dendrimers with cationic and hydrophobic amino acid motifs (such as KK, KA, KH, KL, and LL) distributed across three dendrimer generations was synthesized by a solid-phase protocol that provides ready access to dendrimers in milligram quantities. In conjunction with a lipid component (DOTMA/DOPE), the best reagent, G1,2,3-KL ((LysLeu)8(LysLysLeu)4(LysLysLeu)2LysGlySerCys-NH2), improves transfection by 6–10-fold over commercial reagents under their respective optimal conditions. Emerging structure–activity relationships show that dendrimers with cationic and hydrophobic residues distributed in each generation are transfecting most efficiently. The trigenerational dendritic structure has an advantage over a linear analogue worth up to an order of magnitude. The success of placing the decisive cationic charge patterns in inner shells rather than previously on the surface of macromolecules suggests that this class of dendrimers significantly differs from existing transfection reagents. In the future, this platform may be tuned further and coupled to cell-targeting moieties to enhance transfection and cell specificity. PMID:23682947

  9. Evaluation of three reagent dosing strategies in a photo-Fenton process for the decolorization of azo dye mixtures

    International Nuclear Information System (INIS)

    Prato-Garcia, D.; Buitrón, Germán

    2012-01-01

    Highlights: ► Dosing strategies for a photo-Fenton process were evaluated. ► The dosing strategy had no effect of on the decolorization. ► The type of strategy influenced SUVA index, toxicity reduction and biodegradability. ► A continuous reagents supply was found to be the most adequate strategy. ► Decolorization as well as a less toxic and biodegradable effluent was produced. - Abstract: Three reagent dosing strategies used in the solar photo-assisted decolorization of a mixture of sulfonated dyes consisting of acid blue 113, acid orange 7 and acid red 151 were evaluated. Results demonstrated that the dosing strategy influenced both reagent consumption and the biodegradability and toxicity of the effluent. In one strategy (E 1 ), the Fenton's reactants were dosed in a punctual mode, while in the other two strategies (E 2 an E 3 ), the reactants were dosed continuously. In the E 2 strategy the reactants were dosed by varying the duration of the injection time. In the E 3 strategy, the reactants were dosed during 60 min at a constant rate, but with different concentrations. All cases showed that feeding the reactor between 40% and 60% of the maximal dose was sufficient to decolorize more than 90% of the mixture of azo dyes. The E 1 strategy was less effective for aromatic content reduction. Conversely, the continuous addition of the reagents (E 2 and E 3 strategies) improved the aromatic content removal. E 3 strategy was substantially more appropriate than E 1 strategy due to improved the effluent quality in two key areas: toxicity and biodegradability.

  10. A new turn-on fluorimetric method for the rapid speciation of Cr(III)/Cr(VI) species in tea samples with rhodamine-based fluorescent reagent

    Science.gov (United States)

    Özyol, Esra; Saçmacı, Şerife; Saçmacı, Mustafa; Ülgen, Ahmet

    2018-02-01

    A new fluorimetric method with rhodamine-based fluorescent agent was developed for the rapid speciation of Cr(III)/Cr(VI) in tea, soil and water samples. The system, which utilizes a fluorescent reagent, was used for the first time after synthesis/characterization of 3‧,6‧-bis(diethylamino)-2-{[(1E)-(2,4-dimethoxyphenyl)methylene] amino}spiro[isoindole-1,9‧-xanthen]-3(2H)-one (BDAS). The reagent responds instantaneously at room temperature in a 1:1 stoichiometric manner to the amount of Cr(III). The selectivity of this system for Cr(III) over other metal ions is remarkably high, and its sensitivity is below 0.01 mg L- 1 in aqueous solutions which enables a simplification without any pretreatment of the real sample. The method has a wide linear range of 0.1-10 mg L- 1 and a detection limit of 0.15 μg L- 1 for Cr(III) while the relative standard deviation was 0.1% for 0.1 mg L- 1 Cr(III) concentration. The results of detection and recovery experiments for Cr(III) in tea, soil and water were satisfactory, indicating that the method has better feasibility and application potential in the routine determination and speciation of Cr(III)/Cr(VI). The results of analysis of the certified reference material (INCT-TL-1 tea sample and CWW-TM-D waste water) are in good agreement with the certified value.

  11. A new procedure for the treatment of an industrial waste containing flotation reagents

    Directory of Open Access Journals (Sweden)

    Milosavljević Milutin M.

    2014-01-01

    Full Text Available Flotation reagents can be transformed to industrial waste if they are stored for a long period of time. Also, if synthesis or drying process is not performed under defined conditions in industrial plants, which produce flotation reagents, batch of waste may arise and be stored as a waste. The chemical composition of this waste depends on the phase in which it was created, but typically includes: unreacted alkali hydroxide, solvent - alcohol and trithiocarbonate and oxidation product - dixanthogenate. In this paper a new laboratory procedure for the treatment of such wastes is described. The identification and separation of industrial waste components is also included. From the separated dixantogenate and xanthate a laboratory synthesis of thioncarbamates is given. In addition, a semi-industrial treatment of waste xanthate is presented. Synthesis of N-alkyl and N,N-dialkyl-O-isobutylthioncarbamates were obtained from the filtrate obtained in the first step. As a by-product, sodium thioglycolate was produced. This by-product is transformed to a thioglycolic acid by the addition of an acid. Also, the synthesis of thioncarbamates from dixanthogenates, isolated from industrial waste as a cake, is desribed. Described waste treatment is additionally interesting due to the production of sulphur as another by-product. Laboratory synthesis gave thioncarbamates in yields from 69.7 to 87.7 %, while the semi-industrial process for the selected batches produced thioncarbamates in yields from 74.2 to 80.5 %. Taking into account the importance of the synthesized compounds as selective flotation reagents, a new procedure of their synthesis from industrial waste is characterized by good yields and purity of the obtained compounds, the simplicity of process, low environmental impact and short reaction times of synthesis. [Projekat Ministarstva nauke Republike Srbije, br. III 43007

  12. Derivatization reagents in liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Santa, Tomofumi

    2011-01-01

    Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds. 2010 John Wiley & Sons, Ltd.

  13. Dosimetry of internal emitters - quo vadis?

    International Nuclear Information System (INIS)

    Reddy, A.R.; Nagaratnam, A.; Jain, S.C.; Gupta, M.M.; Mehta, S.C.

    1999-01-01

    The dosimetry of internally administered radiopharmaceuticals in nuclear medicine procedures using MIRD formalisms and dosimetry in the case of intakes of radionuclides and ICRP methodology for the purpose of radiological protection are well established working practices. It should, however, be remembered that dose or dose coefficients calculated refer to a reference individual, defined in terms of a mathematical phantom established on the basis of certain biokinetic reference parameters. The reference individual represents a typical caucasian adult of West Europe or North American origin. Recently, some attempts have been made to define a Reference Asian and a Reference Indian individual and to assess the effects of anatomical differences and changes in the biokinetics of radiopharmaceuticals and other radionuclides in these different reference individuals on the estimation of dose and dose coefficients in relation to the intake of internal radionuclides. The assessment of doses to the embryo/fetus due to intake of radionuclides by pregnant women, local dose estimates, microdosimetry, radiobiology and radiation protection aspects relating to Auger electron emitters represent other areas of active research in the area of dosimetry of internal emitters. The present review summarises these different aspects of work. (orig.) [de

  14. Comparison of ion temperature and ion density measured during geomagnetically very quiet conditions on board of the geophysical rocket ''Vertical-6'' with the international reference ionosphere

    International Nuclear Information System (INIS)

    Bencze, P.; Kovacs, K.; Apathy, I.; Szemerey, I.; Afonin, V.; Bezrukih, V.; Shutte, N.

    1980-05-01

    Ion temperature and ion density, measured on October 25, 1977 during the flight of the geophyisical rocket ''Vertical-6'' by means of a group of five retarding potential analyzers looking into different directions of space, are compared with the International Reference Ionosphere 1978. The measurements were carried out in a geomagnetically quiet period to a height of 1500 km. The results show that both the ion temperature and the ion density are lower than the values predicted by the Reference Ionosphere, the difference is decreasing with increasing altitude. (author)

  15. An air-stable copper reagent for nucleophilic trifluoromethylthiolation of aryl halides

    KAUST Repository

    Weng, Zhiqiang

    2012-12-12

    A series of copper(I) trifluoromethyl thiolate complexes have been synthesized from the reaction of CuF2 with Me3SiCF 3 and S8 (see scheme; Cu red, F green, N blue, S yellow). These air-stable complexes serve as reagents for the efficient conversion of a wide range of aryl halides into the corresponding aryl trifluoromethyl thioethers in excellent yields. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. An air-stable copper reagent for nucleophilic trifluoromethylthiolation of aryl halides

    KAUST Repository

    Weng, Zhiqiang; He, Weiming; Chen, Chaohuang; Lee, Richmond; Tan, Davin; Lai, Zhiping; Kong, Dedao; Yuan, Yaofeng; Huang, Kuo-Wei

    2012-01-01

    A series of copper(I) trifluoromethyl thiolate complexes have been synthesized from the reaction of CuF2 with Me3SiCF 3 and S8 (see scheme; Cu red, F green, N blue, S yellow). These air-stable complexes serve as reagents for the efficient conversion of a wide range of aryl halides into the corresponding aryl trifluoromethyl thioethers in excellent yields. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Glutarimidedioxime: a complexing and reducing reagent for plutonium recovery from spent nuclear fuel reprocessing

    Energy Technology Data Exchange (ETDEWEB)

    Xian, Liang [Radiochemistry Department, China Institute of Atomic Energy, Beijing (China); Tian, Guoxin [Radiochemistry Department, China Institute of Atomic Energy, Beijing (China); Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Beavers, Christine M.; Teat, Simon J. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Shuh, David K. [Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2016-04-04

    Efficient separation processes for recovering uranium and plutonium from spent nuclear fuel are essential to the development of advanced nuclear fuel cycles. The performance characteristics of a new salt-free complexing and reducing reagent, glutarimidedioxime (H{sub 2}A), are reported for recovering plutonium in a PUREX process. With a phase ratio of organic to aqueous of up to 10:1, plutonium can be effectively stripped from 30 % tributyl phosphate (TBP) in kerosene into 1 m HNO{sub 3} with H{sub 2}A. The complexation-reduction mechanism is illustrated with the combination of UV/Vis absorption spectra and the crystal structure of a Pu{sup IV} complex with the reagent. The fast stripping rate and the high efficiency for stripping Pu{sup IV}, through the complexation-reduction mechanism, is suitable for use in centrifugal contactors with very short contact/resident times, thereby offering significant advantages over conventional processes. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. Ring-opening of cyclic ethers with carbon–carbon bond formation by Grignard reagents

    DEFF Research Database (Denmark)

    Christensen, Stig Holden; Holm, Torkil; Madsen, Robert

    2014-01-01

    The ring-opening of cyclic ethers with concomitant C–C bond formation was studied with a number of Grignard reagents. The transformation was performed in a sealed vial by heating to ∼160 °C in an aluminum block or at 180 °C in a microwave oven. Good yields of the product alcohols were obtained...

  19. Organic acids as analytical reagent: Part 1. Estimation of zirconium by gallic acid

    International Nuclear Information System (INIS)

    Pande, C.S.; Singh, A.K.; Kumar, Ashok

    1975-01-01

    Gallic acid has been found to be a selective reagent for the estimation of zirconium. The acid gives crystalline precipitate at pH of 4.8. The precipitate is ignited and weighed as ZrO 2 . Cations like Ca +2 , Ba +2 , Sr +2 , Mn +2 , Co +2 , Ni +2 , Fe +3 do not interfere in the estimation. (author)

  20. Final Report for research grant entitled 'Development of Reagents for Application of At-211 and Bi-213 to Targeted Radiotherapy of Cancer'

    International Nuclear Information System (INIS)

    Wilbur, D. Scott

    2011-01-01

    This grant was a one-year extension of another grant with the same title (DE-FG03-98ER62572). The objective of the studies was to continue in vivo evaluation of reagents to determine which changes in structure were most favorable for in vivo use. The focus of our studies was development and optimization of reagents for pretargeting alpha-emitting radionuclides At-211 or Bi-213 to cancer cells. Testing of the reagents was conducted in vitro and in animal model systems. During the funding period, all three specific aims set out in the proposed studies were worked on, and some additional studies directed at development of a method for direct labeling of proteins with At-211 were investigated. We evaluated reagents in two different approaches in 'two step' pretargeting protocols. These approaches are: (1) delivery of the radionuclide on recombinant streptavidin to bind with pretargeted biotinylated monoclonal antibody (mAb), and alternatively, (2) delivery of the radionuclide on a biotin derivative to bind with pretargeted antibody-streptavidin conjugates. The two approaches were investigated as it was unclear which will be superior for the short half-lived alpha-emitting radionuclides.